Sample records for visualization image-guided procedures

  1. Real-time magnetic resonance-guided ablation of typical right atrial flutter using a combination of active catheter tracking and passive catheter visualization in man: initial results from a consecutive patient series.

    PubMed

    Hilbert, Sebastian; Sommer, Philipp; Gutberlet, Matthias; Gaspar, Thomas; Foldyna, Borek; Piorkowski, Christopher; Weiss, Steffen; Lloyd, Thomas; Schnackenburg, Bernhard; Krueger, Sascha; Fleiter, Christian; Paetsch, Ingo; Jahnke, Cosima; Hindricks, Gerhard; Grothoff, Matthias

    2016-04-01

    Recently cardiac magnetic resonance (CMR) imaging has been found feasible for the visualization of the underlying substrate for cardiac arrhythmias as well as for the visualization of cardiac catheters for diagnostic and ablation procedures. Real-time CMR-guided cavotricuspid isthmus ablation was performed in a series of six patients using a combination of active catheter tracking and catheter visualization using real-time MR imaging. Cardiac magnetic resonance utilizing a 1.5 T system was performed in patients under deep propofol sedation. A three-dimensional-whole-heart sequence with navigator technique and a fast automated segmentation algorithm was used for online segmentation of all cardiac chambers, which were thereafter displayed on a dedicated image guidance platform. In three out of six patients complete isthmus block could be achieved in the MR scanner, two of these patients did not need any additional fluoroscopy. In the first patient technical issues called for a completion of the procedure in a conventional laboratory, in another two patients the isthmus was partially blocked by magnetic resonance imaging (MRI)-guided ablation. The mean procedural time for the MR procedure was 109 ± 58 min. The intubation of the CS was performed within a mean time of 2.75 ± 2.21 min. Total fluoroscopy time for completion of the isthmus block ranged from 0 to 7.5 min. The combination of active catheter tracking and passive real-time visualization in CMR-guided electrophysiologic (EP) studies using advanced interventional hardware and software was safe and enabled efficient navigation, mapping, and ablation. These cases demonstrate significant progress in the development of MR-guided EP procedures. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  2. Robotic System for MRI-Guided Stereotactic Neurosurgery

    PubMed Central

    Li, Gang; Cole, Gregory A.; Shang, Weijian; Harrington, Kevin; Camilo, Alex; Pilitsis, Julie G.; Fischer, Gregory S.

    2015-01-01

    Stereotaxy is a neurosurgical technique that can take several hours to reach a specific target, typically utilizing a mechanical frame and guided by preoperative imaging. An error in any one of the numerous steps or deviations of the target anatomy from the preoperative plan such as brain shift (up to 20 mm), may affect the targeting accuracy and thus the treatment effectiveness. Moreover, because the procedure is typically performed through a small burr hole opening in the skull that prevents tissue visualization, the intervention is basically “blind” for the operator with limited means of intraoperative confirmation that may result in reduced accuracy and safety. The presented system is intended to address the clinical needs for enhanced efficiency, accuracy, and safety of image-guided stereotactic neurosurgery for Deep Brain Stimulation (DBS) lead placement. The work describes a magnetic resonance imaging (MRI)-guided, robotically actuated stereotactic neural intervention system for deep brain stimulation procedure, which offers the potential of reducing procedure duration while improving targeting accuracy and enhancing safety. This is achieved through simultaneous robotic manipulation of the instrument and interactively updated in situ MRI guidance that enables visualization of the anatomy and interventional instrument. During simultaneous actuation and imaging, the system has demonstrated less than 15% signal-to-noise ratio (SNR) variation and less than 0.20% geometric distortion artifact without affecting the imaging usability to visualize and guide the procedure. Optical tracking and MRI phantom experiments streamline the clinical workflow of the prototype system, corroborating targeting accuracy with 3-axis root mean square error 1.38 ± 0.45 mm in tip position and 2.03 ± 0.58° in insertion angle. PMID:25376035

  3. Simulators for training in ultrasound guided procedures.

    PubMed

    Farjad Sultan, Syed; Shorten, George; Iohom, Gabrielle

    2013-06-01

    The four major categories of skill sets associated with proficiency in ultrasound guided regional anaesthesia are 1) understanding device operations, 2) image optimization, 3) image interpretation and 4) visualization of needle insertion and injection of the local anesthetic solution. Of these, visualization of needle insertion and injection of local anaesthetic solution can be practiced using simulators and phantoms. This survey of existing simulators summarizes advantages and disadvantages of each. Current deficits pertain to the validation process.

  4. Value of MR contrast media in image-guided body interventions.

    PubMed

    Saeed, Maythem; Wilson, Mark

    2012-01-28

    In the past few years, there have been multiple advances in magnetic resonance (MR) instrumentation, in vivo devices, real-time imaging sequences and interventional procedures with new therapies. More recently, interventionists have started to use minimally invasive image-guided procedures and local therapies, which reduce the pain from conventional surgery and increase drug effectiveness, respectively. Local therapy also reduces the systemic dose and eliminates the toxic side effects of some drugs to other organs. The success of MR-guided procedures depends on visualization of the targets in 3D and precise deployment of ablation catheters, local therapies and devices. MR contrast media provide a wealth of tissue contrast and allows 3D and 4D image acquisitions. After the development of fast imaging sequences, the clinical applications of MR contrast media have been substantially expanded to include pre- during- and post-interventions. Prior to intervention, MR contrast media have the potential to localize and delineate pathologic tissues of vital organs, such as the brain, heart, breast, kidney, prostate, liver and uterus. They also offer other options such as labeling therapeutic agents or cells. During intervention, these agents have the capability to map blood vessels and enhance the contrast between the endovascular guidewire/catheters/devices, blood and tissues as well as direct therapies to the target. Furthermore, labeling therapeutic agents or cells aids in visualizing their delivery sites and tracking their tissue distribution. After intervention, MR contrast media have been used for assessing the efficacy of ablation and therapies. It should be noted that most image-guided procedures are under preclinical research and development. It can be concluded that MR contrast media have great value in preclinical and some clinical interventional procedures. Future applications of MR contrast media in image-guided procedures depend on their safety, tolerability, tissue specificity and effectiveness in demonstrating success of the interventions and therapies.

  5. Image guided percutaneous spine procedures using an optical see-through head mounted display: proof of concept and rationale.

    PubMed

    Deib, Gerard; Johnson, Alex; Unberath, Mathias; Yu, Kevin; Andress, Sebastian; Qian, Long; Osgood, Gregory; Navab, Nassir; Hui, Ferdinand; Gailloud, Philippe

    2018-05-30

    Optical see-through head mounted displays (OST-HMDs) offer a mixed reality (MixR) experience with unhindered procedural site visualization during procedures using high resolution radiographic imaging. This technical note describes our preliminary experience with percutaneous spine procedures utilizing OST-HMD as an alternative to traditional angiography suite monitors. MixR visualization was achieved using the Microsoft HoloLens system. Various spine procedures (vertebroplasty, kyphoplasty, and percutaneous discectomy) were performed on a lumbar spine phantom with commercially available devices. The HMD created a real time MixR environment by superimposing virtual posteroanterior and lateral views onto the interventionalist's field of view. The procedures were filmed from the operator's perspective. Videos were reviewed to assess whether key anatomic landmarks and materials were reliably visualized. Dosimetry and procedural times were recorded. The operator completed a questionnaire following each procedure, detailing benefits, limitations, and visualization mode preferences. Percutaneous vertebroplasty, kyphoplasty, and discectomy procedures were successfully performed using OST-HMD image guidance on a lumbar spine phantom. Dosimetry and procedural time compared favorably with typical procedural times. Conventional and MixR visualization modes were equally effective in providing image guidance, with key anatomic landmarks and materials reliably visualized. This preliminary study demonstrates the feasibility of utilizing OST-HMDs for image guidance in interventional spine procedures. This novel visualization approach may serve as a valuable adjunct tool during minimally invasive percutaneous spine treatment. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Image-guided techniques in renal and hepatic interventions.

    PubMed

    Najmaei, Nima; Mostafavi, Kamal; Shahbazi, Sahar; Azizian, Mahdi

    2013-12-01

    Development of new imaging technologies and advances in computing power have enabled the physicians to perform medical interventions on the basis of high-quality 3D and/or 4D visualization of the patient's organs. Preoperative imaging has been used for planning the surgery, whereas intraoperative imaging has been widely employed to provide visual feedback to a clinician when he or she is performing the procedure. In the past decade, such systems demonstrated great potential in image-guided minimally invasive procedures on different organs, such as brain, heart, liver and kidneys. This article focuses on image-guided interventions and surgery in renal and hepatic surgeries. A comprehensive search of existing electronic databases was completed for the period of 2000-2011. Each contribution was assessed by the authors for relevance and inclusion. The contributions were categorized on the basis of the type of operation/intervention, imaging modality and specific techniques such as image fusion and augmented reality, and organ motion tracking. As a result, detailed classification and comparative study of various contributions in image-guided renal and hepatic interventions are provided. In addition, the potential future directions have been sketched. With a detailed review of the literature, potential future trends in development of image-guided abdominal interventions are identified, namely, growing use of image fusion and augmented reality, computer-assisted and/or robot-assisted interventions, development of more accurate registration and navigation techniques, and growing applications of intraoperative magnetic resonance imaging. Copyright © 2012 John Wiley & Sons, Ltd.

  7. Assistive technology for ultrasound-guided central venous catheter placement.

    PubMed

    Ikhsan, Mohammad; Tan, Kok Kiong; Putra, Andi Sudjana

    2018-01-01

    This study evaluated the existing technology used to improve the safety and ease of ultrasound-guided central venous catheterization. Electronic database searches were conducted in Scopus, IEEE, Google Patents, and relevant conference databases (SPIE, MICCAI, and IEEE conferences) for related articles on assistive technology for ultrasound-guided central venous catheterization. A total of 89 articles were examined and pointed to several fields that are currently the focus of improvements to ultrasound-guided procedures. These include improving needle visualization, needle guides and localization technology, image processing algorithms to enhance and segment important features within the ultrasound image, robotic assistance using probe-mounted manipulators, and improving procedure ergonomics through in situ projections of important information. Probe-mounted robotic manipulators provide a promising avenue for assistive technology developed for freehand ultrasound-guided percutaneous procedures. However, there is currently a lack of clinical trials to validate the effectiveness of these devices.

  8. Preclinical Feasibility of a Technology Framework for MRI-guided Iliac Angioplasty

    PubMed Central

    Rube, Martin A.; Fernandez-Gutierrez, Fabiola; Cox, Benjamin F.; Holbrook, Andrew B.; Houston, J. Graeme; White, Richard D.; McLeod, Helen; Fatahi, Mahsa; Melzer, Andreas

    2015-01-01

    Purpose Interventional MRI has significant potential for image guidance of iliac angioplasty and related vascular procedures. A technology framework with in-room image display, control, communication and MRI-guided intervention techniques was designed and tested for its potential to provide safe, fast and efficient MRI-guided angioplasty of the iliac arteries. Methods A 1.5T MRI scanner was adapted for interactive imaging during endovascular procedures using new or modified interventional devices such as guidewires and catheters. A perfused vascular phantom was used for testing. Pre-, intra- and post-procedural visualization and measurement of vascular morphology and flow was implemented. A detailed analysis of X-Ray fluoroscopic angiography workflow was conducted and applied. Two interventional radiologists and one physician in training performed 39 procedures. All procedures were timed and analyzed. Results MRI-guided iliac angioplasty procedures were successfully performed with progressive adaptation of techniques and workflow. The workflow, setup and protocol enabled a reduction in table time for a dedicated MRI-guided procedure to 6 min 33 s with a mean procedure time of 9 min 2 s, comparable to the mean procedure time of 8 min 42 s for the standard X-Ray guided procedure. Conclusions MRI-guided iliac vascular interventions were found to be feasible and practical using this framework and optimized workflow. In particular the real-time flow analysis was found to be helpful for pre- and post-interventional assessments. Design optimization of the catheters and in vivo experiments are required before clinical evaluation. PMID:25102933

  9. Fiber optic photoacoustic probe with ultrasonic tracking for guiding minimally invasive procedures

    NASA Astrophysics Data System (ADS)

    Xia, Wenfeng; Mosse, Charles A.; Colchester, Richard J.; Mari, Jean Martial; Nikitichev, Daniil I.; West, Simeon J.; Ourselin, Sebastien; Beard, Paul C.; Desjardins, Adrien E.

    2015-07-01

    In a wide range of clinical procedures, accurate placement of medical devices such as needles and catheters is critical to optimize patient outcomes. Ultrasound imaging is often used to guide minimally invasive procedures, as it can provide real-time visualization of patient anatomy and medical devices. However, this modality can provide low image contrast for soft tissues, and poor visualization of medical devices that are steeply angled with respect to the incoming ultrasound beams. Photoacoustic sensors can provide information about the spatial distributions of tissue chromophores that could be valuable for guiding minimally invasive procedures. In this study, a system for guiding minimally invasive procedures using photoacoustic sensing was developed. This system included a miniature photoacoustic probe with three optical fibers: one with a bare end for photoacoustic excitation of tissue, a second for photoacoustic excitation of an optically absorbing coating at the distal end to transmit ultrasound, and a third with a Fabry-Perot cavity at the distal end for receiving ultrasound. The position of the photoacoustic probe was determined with ultrasonic tracking, which involved transmitting pulses from a linear-array ultrasound imaging probe at the tissue surface, and receiving them with the fiber-optic ultrasound receiver in the photoacoustic probe. The axial resolution of photoacoustic sensing was better than 70 μm, and the tracking accuracy was better than 1 mm in both axial and lateral dimensions. By translating the photoacoustic probe, depth scans were obtained from different spatial positions, and two-dimensional images were reconstructed using a frequency-domain algorithm.

  10. Toward image guided robotic surgery: system validation.

    PubMed

    Herrell, Stanley D; Kwartowitz, David Morgan; Milhoua, Paul M; Galloway, Robert L

    2009-02-01

    Navigation for current robotic assisted surgical techniques is primarily accomplished through a stereo pair of laparoscopic camera images. These images provide standard optical visualization of the surface but provide no subsurface information. Image guidance methods allow the visualization of subsurface information to determine the current position in relationship to that of tracked tools. A robotic image guided surgical system was designed and implemented based on our previous laboratory studies. A series of experiments using tissue mimicking phantoms with injected target lesions was performed. The surgeon was asked to resect "tumor" tissue with and without the augmentation of image guidance using the da Vinci robotic surgical system. Resections were performed and compared to an ideal resection based on the radius of the tumor measured from preoperative computerized tomography. A quantity called the resection ratio, that is the ratio of resected tissue compared to the ideal resection, was calculated for each of 13 trials and compared. The mean +/- SD resection ratio of procedures augmented with image guidance was smaller than that of procedures without image guidance (3.26 +/- 1.38 vs 9.01 +/- 1.81, p <0.01). Additionally, procedures using image guidance were shorter (average 8 vs 13 minutes). It was demonstrated that there is a benefit from the augmentation of laparoscopic video with updated preoperative images. Incorporating our image guided system into the da Vinci robotic system improved overall tissue resection, as measured by our metric. Adding image guidance to the da Vinci robotic surgery system may result in the potential for improvements such as the decreased removal of benign tissue while maintaining an appropriate surgical margin.

  11. Multimodality Non-Rigid Image Registration for Planning, Targeting and Monitoring during CT-guided Percutaneous Liver Tumor Cryoablation

    PubMed Central

    Elhawary, Haytham; Oguro, Sota; Tuncali, Kemal; Morrison, Paul R.; Tatli, Servet; Shyn, Paul B.; Silverman, Stuart G.; Hata, Nobuhiko

    2010-01-01

    Rationale and Objectives To develop non-rigid image registration between pre-procedure contrast enhanced MR images and intra-procedure unenhanced CT images, to enhance tumor visualization and localization during CT-guided liver tumor cryoablation procedures. Materials and Methods After IRB approval, a non-rigid registration (NRR) technique was evaluated with different pre-processing steps and algorithm parameters and compared to a standard rigid registration (RR) approach. The Dice Similarity Coefficient (DSC), Target Registration Error (TRE), 95% Hausdorff distance (HD) and total registration time (minutes) were compared using a two-sided Student’s t-test. The entire registration method was then applied during five CT-guided liver cryoablation cases with the intra-procedural CT data transmitted directly from the CT scanner, with both accuracy and registration time evaluated. Results Selected optimal parameters for registration were section thickness of 5mm, cropping the field of view to 66% of its original size, manual segmentation of the liver, B-spline control grid of 5×5×5 and spatial sampling of 50,000 pixels. Mean 95% HD of 3.3mm (2.5x improvement compared to RR, p<0.05); mean DSC metric of 0.97 (13% increase); and mean TRE of 4.1mm (2.7x reduction) were measured. During the cryoablation procedure registration between the pre-procedure MR and the planning intra-procedure CT took a mean time of 10.6 minutes, the MR to targeting CT image took 4 minutes and MR to monitoring CT took 4.3 minutes. Mean registration accuracy was under 3.4mm. Conclusion Non-rigid registration allowed improved visualization of the tumor during interventional planning, targeting and evaluation of tumor coverage by the ice ball. Future work is focused on reducing segmentation time to make the method more clinically acceptable. PMID:20817574

  12. Real-time MRI guidance of cardiac interventions.

    PubMed

    Campbell-Washburn, Adrienne E; Tavallaei, Mohammad A; Pop, Mihaela; Grant, Elena K; Chubb, Henry; Rhode, Kawal; Wright, Graham A

    2017-10-01

    Cardiac magnetic resonance imaging (MRI) is appealing to guide complex cardiac procedures because it is ionizing radiation-free and offers flexible soft-tissue contrast. Interventional cardiac MR promises to improve existing procedures and enable new ones for complex arrhythmias, as well as congenital and structural heart disease. Guiding invasive procedures demands faster image acquisition, reconstruction and analysis, as well as intuitive intraprocedural display of imaging data. Standard cardiac MR techniques such as 3D anatomical imaging, cardiac function and flow, parameter mapping, and late-gadolinium enhancement can be used to gather valuable clinical data at various procedural stages. Rapid intraprocedural image analysis can extract and highlight critical information about interventional targets and outcomes. In some cases, real-time interactive imaging is used to provide a continuous stream of images displayed to interventionalists for dynamic device navigation. Alternatively, devices are navigated relative to a roadmap of major cardiac structures generated through fast segmentation and registration. Interventional devices can be visualized and tracked throughout a procedure with specialized imaging methods. In a clinical setting, advanced imaging must be integrated with other clinical tools and patient data. In order to perform these complex procedures, interventional cardiac MR relies on customized equipment, such as interactive imaging environments, in-room image display, audio communication, hemodynamic monitoring and recording systems, and electroanatomical mapping and ablation systems. Operating in this sophisticated environment requires coordination and planning. This review provides an overview of the imaging technology used in MRI-guided cardiac interventions. Specifically, this review outlines clinical targets, standard image acquisition and analysis tools, and the integration of these tools into clinical workflow. 1 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2017;46:935-950. © 2017 International Society for Magnetic Resonance in Medicine.

  13. Feasibility of real-time magnetic resonance imaging-guided endomyocardial biopsies: An in-vitro study.

    PubMed

    Lossnitzer, Dirk; Seitz, Sebastian A; Krautz, Birgit; Schnackenburg, Bernhard; André, Florian; Korosoglou, Grigorios; Katus, Hugo A; Steen, Henning

    2015-07-26

    To investigate if magnetic resonance (MR)-guided biopsy can improve the performance and safety of such procedures. A novel MR-compatible bioptome was evaluated in a series of in-vitro experiments in a 1.5T magnetic resonance imaging (MRI) system. The bioptome was inserted into explanted porcine and bovine hearts under real-time MR-guidance employing a steady state free precession sequence. The artifact produced by the metal element at the tip and the signal voids caused by the bioptome were visually tracked for navigation and allowed its constant and precise localization. Cardiac structural elements and the target regions for the biopsy were clearly visible. Our method allowed a significantly better spatial visualization of the bioptoms tip compared to conventional X-ray guidance. The specific device design of the bioptome avoided inducible currents and therefore subsequent heating. The novel MR-compatible bioptome provided a superior cardiovascular magnetic resonance (imaging) soft-tissue visualization for MR-guided myocardial biopsies. Not at least the use of MRI guidance for endomyocardial biopsies completely avoided radiation exposure for both patients and interventionalists. MRI-guided endomyocardial biopsies provide a better than conventional X-ray guided navigation and could therefore improve the specificity and reproducibility of cardiac biopsies in future studies.

  14. Sonification of optical coherence tomography data and images

    PubMed Central

    Ahmad, Adeel; Adie, Steven G.; Wang, Morgan; Boppart, Stephen A.

    2010-01-01

    Sonification is the process of representing data as non-speech audio signals. In this manuscript, we describe the auditory presentation of OCT data and images. OCT acquisition rates frequently exceed our ability to visually analyze image-based data, and multi-sensory input may therefore facilitate rapid interpretation. This conversion will be especially valuable in time-sensitive surgical or diagnostic procedures. In these scenarios, auditory feedback can complement visual data without requiring the surgeon to constantly monitor the screen, or provide additional feedback in non-imaging procedures such as guided needle biopsies which use only axial-scan data. In this paper we present techniques to translate OCT data and images into sound based on the spatial and spatial frequency properties of the OCT data. Results obtained from parameter-mapped sonification of human adipose and tumor tissues are presented, indicating that audio feedback of OCT data may be useful for the interpretation of OCT images. PMID:20588846

  15. Echocardiographic and Fluoroscopic Fusion Imaging for Procedural Guidance: An Overview and Early Clinical Experience.

    PubMed

    Thaden, Jeremy J; Sanon, Saurabh; Geske, Jeffrey B; Eleid, Mackram F; Nijhof, Niels; Malouf, Joseph F; Rihal, Charanjit S; Bruce, Charles J

    2016-06-01

    There has been significant growth in the volume and complexity of percutaneous structural heart procedures in the past decade. Increasing procedural complexity and accompanying reliance on multimodality imaging have fueled the development of fusion imaging to facilitate procedural guidance. The first clinically available system capable of echocardiographic and fluoroscopic fusion for real-time guidance of structural heart procedures was approved by the US Food and Drug Administration in 2012. Echocardiographic-fluoroscopic fusion imaging combines the precise catheter and device visualization of fluoroscopy with the soft tissue anatomy and color flow Doppler information afforded by echocardiography in a single image. This allows the interventionalist to perform precise catheter manipulations under fluoroscopy guidance while visualizing critical tissue anatomy provided by echocardiography. However, there are few data available addressing this technology's strengths and limitations in routine clinical practice. The authors provide a critical review of currently available echocardiographic-fluoroscopic fusion imaging for guidance of structural heart interventions to highlight its strengths, limitations, and potential clinical applications and to guide further research into value of this emerging technology. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  16. Image-guided robotic surgery.

    PubMed

    Marescaux, Jacques; Solerc, Luc

    2004-06-01

    Medical image processing leads to an improvement in patient care by guiding the surgical gesture. Three-dimensional models of patients that are generated from computed tomographic scans or magnetic resonance imaging allow improved surgical planning and surgical simulation that offers the opportunity for a surgeon to train the surgical gesture before performing it for real. These two preoperative steps can be used intra-operatively because of the development of augmented reality, which consists of superimposing the preoperative three-dimensional model of the patient onto the real intraoperative view. Augmented reality provides the surgeon with a view of the patient in transparency and can also guide the surgeon, thanks to the real-time tracking of surgical tools during the procedure. When adapted to robotic surgery, this tool tracking enables visual serving with the ability to automatically position and control surgical robotic arms in three dimensions. It is also now possible to filter physiologic movements such as breathing or the heart beat. In the future, by combining augmented reality and robotics, these image-guided robotic systems will enable automation of the surgical procedure, which will be the next revolution in surgery.

  17. Fluorescence-Guided Surgery

    PubMed Central

    Nagaya, Tadanobu; Nakamura, Yu A.; Choyke, Peter L.; Kobayashi, Hisataka

    2017-01-01

    Surgical resection of cancer remains an important treatment modality. Despite advances in preoperative imaging, surgery itself is primarily guided by the surgeon’s ability to locate pathology with conventional white light imaging. Fluorescence-guided surgery (FGS) can be used to define tumor location and margins during the procedure. Intraoperative visualization of tumors may not only allow more complete resections but also improve safety by avoiding unnecessary damage to normal tissue which can also reduce operative time and decrease the need for second-look surgeries. A number of new FGS imaging probes have recently been developed, complementing a small but useful number of existing probes. In this review, we describe current and new fluorescent probes that may assist FGS. PMID:29312886

  18. Radioguided surgery and the GOSTT concept: From pre-operative image and intraoperative navigation to image-assisted excision.

    PubMed

    Bowles, H; Sánchez, N; Tapias, A; Paredes, P; Campos, F; Bluemel, C; Valdés Olmos, R A; Vidal-Sicart, S

    Radio-guided surgery has been developed for application in those disease scheduled for surgical management, particularly in areas of complex anatomy. This is based on the use of pre-operative scintigraphic planar, tomographic and fused SPECT/CT images, and the possibility of 3D reconstruction for the subsequent intraoperative locating of active lesions using handheld devices (detection probes, gamma cameras, etc.). New tracers and technologies have also been incorporated into these surgical procedures. The combination of visual and acoustic signals during the intraoperative procedure has become possible with new portable imaging modalities. In daily practice, the images offered by these techniques and devices combine perioperative nuclear medicine imaging with the superior resolution of additional optical guidance in the operating room. In many ways they provide real-time images, allowing accurate guidance during surgery, a reduction in the time required for tissue location and an anatomical environment for surgical recognition. All these approaches have been included in the concept known as (radio) Guided intraOperative Scintigraphic Tumour Targeting (GOSTT). This article offers a general view of different nuclear medicine and allied technologies used for several GOSTT procedures, and illustrates the crossing of technological frontiers in radio-guided surgery. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  19. Fluorescence-guided tumor visualization using a custom designed NIR attachment to a surgical microscope for high sensitivity imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Kittle, David S.; Patil, Chirag G.; Mamelak, Adam; Hansen, Stacey; Perry, Jeff; Ishak, Laura; Black, Keith L.; Butte, Pramod V.

    2016-03-01

    Current surgical microscopes are limited in sensitivity for NIR fluorescence. Recent developments in tumor markers attached with NIR dyes require newer, more sensitive imaging systems with high resolution to guide surgical resection. We report on a small, single camera solution enabling advanced image processing opportunities previously unavailable for ultra-high sensitivity imaging of these agents. The system captures both visible reflectance and NIR fluorescence at 300 fps while displaying full HD resolution video at 60 fps. The camera head has been designed to easily mount onto the Zeiss Pentero microscope head for seamless integration into surgical procedures.

  20. Designing Tracking Software for Image-Guided Surgery Applications: IGSTK Experience

    PubMed Central

    Enquobahrie, Andinet; Gobbi, David; Turek, Matt; Cheng, Patrick; Yaniv, Ziv; Lindseth, Frank; Cleary, Kevin

    2009-01-01

    Objective Many image-guided surgery applications require tracking devices as part of their core functionality. The Image-Guided Surgery Toolkit (IGSTK) was designed and developed to interface tracking devices with software applications incorporating medical images. Methods IGSTK was designed as an open source C++ library that provides the basic components needed for fast prototyping and development of image-guided surgery applications. This library follows a component-based architecture with several components designed for specific sets of image-guided surgery functions. At the core of the toolkit is the tracker component that handles communication between a control computer and navigation device to gather pose measurements of surgical instruments present in the surgical scene. The representations of the tracked instruments are superimposed on anatomical images to provide visual feedback to the clinician during surgical procedures. Results The initial version of the IGSTK toolkit has been released in the public domain and several trackers are supported. The toolkit and related information are available at www.igstk.org. Conclusion With the increased popularity of minimally invasive procedures in health care, several tracking devices have been developed for medical applications. Designing and implementing high-quality and safe software to handle these different types of trackers in a common framework is a challenging task. It requires establishing key software design principles that emphasize abstraction, extensibility, reusability, fault-tolerance, and portability. IGSTK is an open source library that satisfies these needs for the image-guided surgery community. PMID:20037671

  1. Compact fluorescence and white-light imaging system for intraoperative visualization of nerves

    NASA Astrophysics Data System (ADS)

    Gray, Dan; Kim, Evgenia; Cotero, Victoria; Staudinger, Paul; Yazdanfar, Siavash; tan Hehir, Cristina

    2012-02-01

    Fluorescence image guided surgery (FIGS) allows intraoperative visualization of critical structures, with applications spanning neurology, cardiology and oncology. An unmet clinical need is prevention of iatrogenic nerve damage, a major cause of post-surgical morbidity. Here we describe the advancement of FIGS imaging hardware, coupled with a custom nerve-labeling fluorophore (GE3082), to bring FIGS nerve imaging closer to clinical translation. The instrument is comprised of a 405nm laser and a white light LED source for excitation and illumination. A single 90 gram color CCD camera is coupled to a 10mm surgical laparoscope for image acquisition. Synchronization of the light source and camera allows for simultaneous visualization of reflected white light and fluorescence using only a single camera. The imaging hardware and contrast agent were evaluated in rats during in situ surgical procedures.

  2. A compact fluorescence and white light imaging system for intraoperative visualization of nerves

    NASA Astrophysics Data System (ADS)

    Gray, Dan; Kim, Evgenia; Cotero, Victoria; Staudinger, Paul; Yazdanfar, Siavash; Tan Hehir, Cristina

    2012-03-01

    Fluorescence image guided surgery (FIGS) allows intraoperative visualization of critical structures, with applications spanning neurology, cardiology and oncology. An unmet clinical need is prevention of iatrogenic nerve damage, a major cause of post-surgical morbidity. Here we describe the advancement of FIGS imaging hardware, coupled with a custom nerve-labeling fluorophore (GE3082), to bring FIGS nerve imaging closer to clinical translation. The instrument is comprised of a 405nm laser and a white light LED source for excitation and illumination. A single 90 gram color CCD camera is coupled to a 10mm surgical laparoscope for image acquisition. Synchronization of the light source and camera allows for simultaneous visualization of reflected white light and fluorescence using only a single camera. The imaging hardware and contrast agent were evaluated in rats during in situ surgical procedures.

  3. Multimode C-arm fluoroscopy, tomosynthesis, and cone-beam CT for image-guided interventions: from proof of principle to patient protocols

    NASA Astrophysics Data System (ADS)

    Siewerdsen, J. H.; Daly, M. J.; Bachar, G.; Moseley, D. J.; Bootsma, G.; Brock, K. K.; Ansell, S.; Wilson, G. A.; Chhabra, S.; Jaffray, D. A.; Irish, J. C.

    2007-03-01

    High-performance intraoperative imaging is essential to an ever-expanding scope of therapeutic procedures ranging from tumor surgery to interventional radiology. The need for precise visualization of bony and soft-tissue structures with minimal obstruction to the therapy setup presents challenges and opportunities in the development of novel imaging technologies specifically for image-guided procedures. Over the past ~5 years, a mobile C-arm has been modified in collaboration with Siemens Medical Solutions for 3D imaging. Based upon a Siemens PowerMobil, the device includes: a flat-panel detector (Varian PaxScan 4030CB); a motorized orbit; a system for geometric calibration; integration with real-time tracking and navigation (NDI Polaris); and a computer control system for multi-mode fluoroscopy, tomosynthesis, and cone-beam CT. Investigation of 3D imaging performance (noise-equivalent quanta), image quality (human observer studies), and image artifacts (scatter, truncation, and cone-beam artifacts) has driven the development of imaging techniques appropriate to a host of image-guided interventions. Multi-mode functionality presents a valuable spectrum of acquisition techniques: i.) fluoroscopy for real-time 2D guidance; ii.) limited-angle tomosynthesis for fast 3D imaging (e.g., ~10 sec acquisition of coronal slices containing the surgical target); and iii.) fully 3D cone-beam CT (e.g., ~30-60 sec acquisition providing bony and soft-tissue visualization across the field of view). Phantom and cadaver studies clearly indicate the potential for improved surgical performance - up to a factor of 2 increase in challenging surgical target excisions. The C-arm system is currently being deployed in patient protocols ranging from brachytherapy to chest, breast, spine, and head and neck surgery.

  4. Dynamic optical projection of acquired luminescence for aiding oncologic surgery

    NASA Astrophysics Data System (ADS)

    Sarder, Pinaki; Gullicksrud, Kyle; Mondal, Suman; Sudlow, Gail P.; Achilefu, Samuel; Akers, Walter J.

    2013-12-01

    Optical imaging enables real-time visualization of intrinsic and exogenous contrast within biological tissues. Applications in human medicine have demonstrated the power of fluorescence imaging to enhance visualization in dermatology, endoscopic procedures, and open surgery. Although few optical contrast agents are available for human medicine at this time, fluorescence imaging is proving to be a powerful tool in guiding medical procedures. Recently, intraoperative detection of fluorescent molecular probes that target cell-surface receptors has been reported for improvement in oncologic surgery in humans. We have developed a novel system, optical projection of acquired luminescence (OPAL), to further enhance real-time guidance of open oncologic surgery. In this method, collected fluorescence intensity maps are projected onto the imaged surface rather than via wall-mounted display monitor. To demonstrate proof-of-principle for OPAL applications in oncologic surgery, lymphatic transport of indocyanine green was visualized in live mice for intraoperative identification of sentinel lymph nodes. Subsequently, peritoneal tumors in a murine model of breast cancer metastasis were identified using OPAL after systemic administration of a tumor-selective fluorescent molecular probe. These initial results clearly show that OPAL can enhance adoption and ease-of-use of fluorescence imaging in oncologic procedures relative to existing state-of-the-art intraoperative imaging systems.

  5. Visualization of risk structures for interactive planning of image guided radiofrequency ablation of liver tumors

    NASA Astrophysics Data System (ADS)

    Rieder, Christian; Schwier, Michael; Weihusen, Andreas; Zidowitz, Stephan; Peitgen, Heinz-Otto

    2009-02-01

    Image guided radiofrequency ablation (RFA) is becoming a standard procedure as a minimally invasive method for tumor treatment in the clinical routine. The visualization of pathological tissue and potential risk structures like vessels or important organs gives essential support in image guided pre-interventional RFA planning. In this work our aim is to present novel visualization techniques for interactive RFA planning to support the physician with spatial information of pathological structures as well as the finding of trajectories without harming vitally important tissue. Furthermore, we illustrate three-dimensional applicator models of different manufactures combined with corresponding ablation areas in homogenous tissue, as specified by the manufacturers, to enhance the estimated amount of cell destruction caused by ablation. The visualization techniques are embedded in a workflow oriented application, designed for the use in the clinical routine. To allow a high-quality volume rendering we integrated a visualization method using the fuzzy c-means algorithm. This method automatically defines a transfer function for volume visualization of vessels without the need of a segmentation mask. However, insufficient visualization results of the displayed vessels caused by low data quality can be improved using local vessel segmentation in the vicinity of the lesion. We also provide an interactive segmentation technique of liver tumors for the volumetric measurement and for the visualization of pathological tissue combined with anatomical structures. In order to support coagulation estimation with respect to the heat-sink effect of the cooling blood flow which decreases thermal ablation, a numerical simulation of the heat distribution is provided.

  6. Augmented reality-guided neurosurgery: accuracy and intraoperative application of an image projection technique.

    PubMed

    Besharati Tabrizi, Leila; Mahvash, Mehran

    2015-07-01

    An augmented reality system has been developed for image-guided neurosurgery to project images with regions of interest onto the patient's head, skull, or brain surface in real time. The aim of this study was to evaluate system accuracy and to perform the first intraoperative application. Images of segmented brain tumors in different localizations and sizes were created in 10 cases and were projected to a head phantom using a video projector. Registration was performed using 5 fiducial markers. After each registration, the distance of the 5 fiducial markers from the visualized tumor borders was measured on the virtual image and on the phantom. The difference was considered a projection error. Moreover, the image projection technique was intraoperatively applied in 5 patients and was compared with a standard navigation system. Augmented reality visualization of the tumors succeeded in all cases. The mean time for registration was 3.8 minutes (range 2-7 minutes). The mean projection error was 0.8 ± 0.25 mm. There were no significant differences in accuracy according to the localization and size of the tumor. Clinical feasibility and reliability of the augmented reality system could be proved intraoperatively in 5 patients (projection error 1.2 ± 0.54 mm). The augmented reality system is accurate and reliable for the intraoperative projection of images to the head, skull, and brain surface. The ergonomic advantage of this technique improves the planning of neurosurgical procedures and enables the surgeon to use direct visualization for image-guided neurosurgery.

  7. Image-guided transnasal cryoablation of a recurrent nasal adenocarcinoma in a dog.

    PubMed

    Murphy, S M; Lawrence, J A; Schmiedt, C W; Davis, K W; Lee, F T; Forrest, L J; Bjorling, D E

    2011-06-01

    An eight-year-old female spayed Airedale terrier with rapid recurrence of a nasal adenocarcinoma following image-guided intensity-modulated radiation therapy was treated with transnasal, image-guided cryotherapy. Ice ball size and location were monitored real-time with computed tomography-fluoroscopy to verify that the entire tumour was enveloped in ice. Serial computed tomography scans demonstrated reduction in and subsequent resolution of the primary tumour volume corresponding visually with the ice ball imaged during the ablation procedure. Re-imaging demonstrated focallysis of the cribriform plate following ablation that spontaneously resolved by 13 months. While mild chronic nasal discharge developed following cryoablation, no other clinical signs of local nasal neoplasia were present. Twenty-one months after nasal tumour cryoablation the dog was euthanased as a result of acute haemoabdomen. Image-guided cryotherapy may warrant further investigation for the management of focal residual or recurrent tumours in dogs, especially in regions where critical structures preclude surgical intervention. © 2011 British Small Animal Veterinary Association.

  8. Navigation for fluoroscopy-guided cryo-balloon ablation procedures of atrial fibrillation

    NASA Astrophysics Data System (ADS)

    Bourier, Felix; Brost, Alexander; Kleinoeder, Andreas; Kurzendorfer, Tanja; Koch, Martin; Kiraly, Attila; Schneider, Hans-Juergen; Hornegger, Joachim; Strobel, Norbert; Kurzidim, Klaus

    2012-02-01

    Atrial fibrillation (AFib), the most common arrhythmia, has been identified as a major cause of stroke. The current standard in interventional treatment of AFib is the pulmonary vein isolation (PVI). PVI is guided by fluoroscopy or non-fluoroscopic electro-anatomic mapping systems (EAMS). Either classic point-to-point radio-frequency (RF)- catheter ablation or so-called single-shot-devices like cryo-balloons are used to achieve electrically isolation of the pulmonary veins and the left atrium (LA). Fluoroscopy-based systems render overlay images from pre-operative 3-D data sets which are then merged with fluoroscopic imaging, thereby adding detailed 3-D information to conventional fluoroscopy. EAMS provide tracking and visualization of RF catheters by means of electro-magnetic tracking. Unfortunately, current navigation systems, fluoroscopy-based or EAMS, do not provide tools to localize and visualize single shot devices like cryo-balloon catheters in 3-D. We present a prototype software for fluoroscopy-guided ablation procedures that is capable of superimposing 3-D datasets as well as reconstructing cyro-balloon catheters in 3-D. The 3-D cyro-balloon reconstruction was evaluated on 9 clinical data sets, yielded a reprojected 2-D error of 1.72 mm +/- 1.02 mm.

  9. Real-time three-dimensional optical coherence tomography image-guided core-needle biopsy system.

    PubMed

    Kuo, Wei-Cheng; Kim, Jongsik; Shemonski, Nathan D; Chaney, Eric J; Spillman, Darold R; Boppart, Stephen A

    2012-06-01

    Advances in optical imaging modalities, such as optical coherence tomography (OCT), enable us to observe tissue microstructure at high resolution and in real time. Currently, core-needle biopsies are guided by external imaging modalities such as ultrasound imaging and x-ray computed tomography (CT) for breast and lung masses, respectively. These image-guided procedures are frequently limited by spatial resolution when using ultrasound imaging, or by temporal resolution (rapid real-time feedback capabilities) when using x-ray CT. One feasible approach is to perform OCT within small gauge needles to optically image tissue microstructure. However, to date, no system or core-needle device has been developed that incorporates both three-dimensional OCT imaging and tissue biopsy within the same needle for true OCT-guided core-needle biopsy. We have developed and demonstrate an integrated core-needle biopsy system that utilizes catheter-based 3-D OCT for real-time image-guidance for target tissue localization, imaging of tissue immediately prior to physical biopsy, and subsequent OCT imaging of the biopsied specimen for immediate assessment at the point-of-care. OCT images of biopsied ex vivo tumor specimens acquired during core-needle placement are correlated with corresponding histology, and computational visualization of arbitrary planes within the 3-D OCT volumes enables feedback on specimen tissue type and biopsy quality. These results demonstrate the potential for using real-time 3-D OCT for needle biopsy guidance by imaging within the needle and tissue during biopsy procedures.

  10. Transthoracic ultrasound guided balloon dilation of cor triatriatum dexter in 2 Rottweiler puppies.

    PubMed

    Birettoni, F; Caivano, D; Bufalari, A; Giorgi, M E; Miglio, A; Paradies, P; Porciello, F

    2016-12-01

    Balloon dilation was performed in two Rottweiler puppies with cor triatriatum dexter and clinical signs of ascites using transthoracic echocardiographic guidance. The dogs were positioned on a standard echocardiography table in right lateral recumbency, and guide wires and balloon catheters were imaged by echocardiographic views optimized to allow visualization of the defect. The procedures were performed successfully without complications and clinical signs were resolved completely in both cases. Guide wires and balloon catheters appeared hyperechoic on transthoracic echocardiography image and could be clearly monitored and guided in real-time. These two cases demonstrate that it is possible to perform balloon catheter dilation of cor triatriatum dexter under transthoracic guidance alone. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. CBCT-based 3D MRA and angiographic image fusion and MRA image navigation for neuro interventions.

    PubMed

    Zhang, Qiang; Zhang, Zhiqiang; Yang, Jiakang; Sun, Qi; Luo, Yongchun; Shan, Tonghui; Zhang, Hao; Han, Jingfeng; Liang, Chunyang; Pan, Wenlong; Gu, Chuanqi; Mao, Gengsheng; Xu, Ruxiang

    2016-08-01

    Digital subtracted angiography (DSA) remains the gold standard for diagnosis of cerebral vascular diseases and provides intraprocedural guidance. This practice involves extensive usage of x-ray and iodinated contrast medium, which can induce side effects. In this study, we examined the accuracy of 3-dimensional (3D) registration of magnetic resonance angiography (MRA) and DSA imaging for cerebral vessels, and tested the feasibility of using preprocedural MRA for real-time guidance during endovascular procedures.Twenty-three patients with suspected intracranial arterial lesions were enrolled. The contrast medium-enhanced 3D DSA of target vessels were acquired in 19 patients during endovascular procedures, and the images were registered with preprocedural MRA for fusion accuracy evaluation. Low-dose noncontrasted 3D angiography of the skull was performed in the other 4 patients, and registered with the MRA. The MRA was overlaid afterwards with 2D live fluoroscopy to guide endovascular procedures.The 3D registration of the MRA and angiography demonstrated a high accuracy for vessel lesion visualization in all 19 patients examined. Moreover, MRA of the intracranial vessels, registered to the noncontrasted 3D angiography in the 4 patients, provided real-time 3D roadmap to successfully guide the endovascular procedures. Radiation dose to patients and contrast medium usage were shown to be significantly reduced.Three-dimensional MRA and angiography fusion can accurately generate cerebral vasculature images to guide endovascular procedures. The use of the fusion technology could enhance clinical workflow while minimizing contrast medium usage and radiation dose, and hence lowering procedure risks and increasing treatment safety.

  12. CBCT-based 3D MRA and angiographic image fusion and MRA image navigation for neuro interventions

    PubMed Central

    Zhang, Qiang; Zhang, Zhiqiang; Yang, Jiakang; Sun, Qi; Luo, Yongchun; Shan, Tonghui; Zhang, Hao; Han, Jingfeng; Liang, Chunyang; Pan, Wenlong; Gu, Chuanqi; Mao, Gengsheng; Xu, Ruxiang

    2016-01-01

    Abstract Digital subtracted angiography (DSA) remains the gold standard for diagnosis of cerebral vascular diseases and provides intraprocedural guidance. This practice involves extensive usage of x-ray and iodinated contrast medium, which can induce side effects. In this study, we examined the accuracy of 3-dimensional (3D) registration of magnetic resonance angiography (MRA) and DSA imaging for cerebral vessels, and tested the feasibility of using preprocedural MRA for real-time guidance during endovascular procedures. Twenty-three patients with suspected intracranial arterial lesions were enrolled. The contrast medium-enhanced 3D DSA of target vessels were acquired in 19 patients during endovascular procedures, and the images were registered with preprocedural MRA for fusion accuracy evaluation. Low-dose noncontrasted 3D angiography of the skull was performed in the other 4 patients, and registered with the MRA. The MRA was overlaid afterwards with 2D live fluoroscopy to guide endovascular procedures. The 3D registration of the MRA and angiography demonstrated a high accuracy for vessel lesion visualization in all 19 patients examined. Moreover, MRA of the intracranial vessels, registered to the noncontrasted 3D angiography in the 4 patients, provided real-time 3D roadmap to successfully guide the endovascular procedures. Radiation dose to patients and contrast medium usage were shown to be significantly reduced. Three-dimensional MRA and angiography fusion can accurately generate cerebral vasculature images to guide endovascular procedures. The use of the fusion technology could enhance clinical workflow while minimizing contrast medium usage and radiation dose, and hence lowering procedure risks and increasing treatment safety. PMID:27512846

  13. Preliminary study of ergonomic behavior during simulated ultrasound-guided regional anesthesia using a head-mounted display.

    PubMed

    Udani, Ankeet D; Harrison, T Kyle; Howard, Steven K; Kim, T Edward; Brock-Utne, John G; Gaba, David M; Mariano, Edward R

    2012-08-01

    A head-mounted display provides continuous real-time imaging within the practitioner's visual field. We evaluated the feasibility of using head-mounted display technology to improve ergonomics in ultrasound-guided regional anesthesia in a simulated environment. Two anesthesiologists performed an equal number of ultrasound-guided popliteal-sciatic nerve blocks using the head-mounted display on a porcine hindquarter, and an independent observer assessed each practitioner's ergonomics (eg, head turning, arching, eye movements, and needle manipulation) and the overall block quality based on the injectate spread around the target nerve for each procedure. Both practitioners performed their procedures without directly viewing the ultrasound monitor, and neither practitioner showed poor ergonomic behavior. Head-mounted display technology may offer potential advantages during ultrasound-guided regional anesthesia.

  14. An ultra-high field strength MR image-guided robotic needle delivery system for in-bore small animal interventions.

    PubMed

    Gravett, Matthew; Cepek, Jeremy; Fenster, Aaron

    2017-11-01

    The purpose of this study was to develop and validate an image-guided robotic needle delivery system for accurate and repeatable needle targeting procedures in mouse brains inside the 12 cm inner diameter gradient coil insert of a 9.4 T MR scanner. Many preclinical research techniques require the use of accurate needle deliveries to soft tissues, including brain tissue. Soft tissues are optimally visualized in MR images, which offer high-soft tissue contrast, as well as a range of unique imaging techniques, including functional, spectroscopy and thermal imaging, however, there are currently no solutions for delivering needles to small animal brains inside the bore of an ultra-high field MR scanner. This paper describes the mechatronic design, evaluation of MR compatibility, registration technique, mechanical calibration, the quantitative validation of the in-bore image-guided needle targeting accuracy and repeatability, and demonstrated the system's ability to deliver needles in situ. Our six degree-of-freedom, MR compatible, mechatronic system was designed to fit inside the bore of a 9.4 T MR scanner and is actuated using a combination of piezoelectric and hydraulic mechanisms. The MR compatibility and targeting accuracy of the needle delivery system are evaluated to ensure that the system is precisely calibrated to perform the needle targeting procedures. A semi-automated image registration is performed to link the robot coordinates to the MR coordinate system. Soft tissue targets can be accurately localized in MR images, followed by automatic alignment of the needle trajectory to the target. Intra-procedure visualization of the needle target location and the needle were confirmed through MR images after needle insertion. The effects of geometric distortions and signal noise were found to be below threshold that would have an impact on the accuracy of the system. The system was found to have negligible effect on the MR image signal noise and geometric distortion. The system was mechanically calibrated and the mean image-guided needle targeting and needle trajectory accuracies were quantified in an image-guided tissue mimicking phantom experiment to be 178 ± 54 μm and 0.27 ± 0.65°, respectively. An MR image-guided system for in-bore needle deliveries to soft tissue targets in small animal models has been developed. The results of the needle targeting accuracy experiments in phantoms indicate that this system has the potential to deliver needles to the smallest soft tissue structures relevant in preclinical studies, at a wide variety of needle trajectories. Future work in the form of a fully-automated needle driver with precise depth control would benefit this system in terms of its applicability to a wider range of animal models and organ targets. © 2017 American Association of Physicists in Medicine.

  15. Accuracy assessment of fluoroscopy-transesophageal echocardiography registration

    NASA Astrophysics Data System (ADS)

    Lang, Pencilla; Seslija, Petar; Bainbridge, Daniel; Guiraudon, Gerard M.; Jones, Doug L.; Chu, Michael W.; Holdsworth, David W.; Peters, Terry M.

    2011-03-01

    This study assesses the accuracy of a new transesophageal (TEE) ultrasound (US) fluoroscopy registration technique designed to guide percutaneous aortic valve replacement. In this minimally invasive procedure, a valve is inserted into the aortic annulus via a catheter. Navigation and positioning of the valve is guided primarily by intra-operative fluoroscopy. Poor anatomical visualization of the aortic root region can result in incorrect positioning, leading to heart valve embolization, obstruction of the coronary ostia and acute kidney injury. The use of TEE US images to augment intra-operative fluoroscopy provides significant improvements to image-guidance. Registration is achieved using an image-based TEE probe tracking technique and US calibration. TEE probe tracking is accomplished using a single-perspective pose estimation algorithm. Pose estimation from a single image allows registration to be achieved using only images collected in standard OR workflow. Accuracy of this registration technique is assessed using three models: a point target phantom, a cadaveric porcine heart with implanted fiducials, and in-vivo porcine images. Results demonstrate that registration can be achieved with an RMS error of less than 1.5mm, which is within the clinical accuracy requirements of 5mm. US-fluoroscopy registration based on single-perspective pose estimation demonstrates promise as a method for providing guidance to percutaneous aortic valve replacement procedures. Future work will focus on real-time implementation and a visualization system that can be used in the operating room.

  16. Enhanced visualization of the bile duct via parallel white light and indocyanine green fluorescence laparoscopic imaging

    NASA Astrophysics Data System (ADS)

    Demos, Stavros G.; Urayama, Shiro

    2014-03-01

    Despite best efforts, bile duct injury during laparoscopic cholecystectomy is a major potential complication. Precise detection method of extrahepatic bile duct during laparoscopic procedures would minimize the risk of injury. Towards this goal, we have developed a compact imaging instrumentation designed to enable simultaneous acquisition of conventional white color and NIR fluorescence endoscopic/laparoscopic imaging using ICG as contrast agent. The capabilities of this system, which offers optimized sensitivity and functionality, are demonstrated for the detection of the bile duct in an animal model. This design could also provide a low-cost real-time surgical navigation capability to enhance the efficacy of a variety of other image-guided minimally invasive procedures.

  17. Design and implementation of a PC-based image-guided surgical system.

    PubMed

    Stefansic, James D; Bass, W Andrew; Hartmann, Steven L; Beasley, Ryan A; Sinha, Tuhin K; Cash, David M; Herline, Alan J; Galloway, Robert L

    2002-11-01

    In interactive, image-guided surgery, current physical space position in the operating room is displayed on various sets of medical images used for surgical navigation. We have developed a PC-based surgical guidance system (ORION) which synchronously displays surgical position on up to four image sets and updates them in real time. There are three essential components which must be developed for this system: (1) accurately tracked instruments; (2) accurate registration techniques to map physical space to image space; and (3) methods to display and update the image sets on a computer monitor. For each of these components, we have developed a set of dynamic link libraries in MS Visual C++ 6.0 supporting various hardware tools and software techniques. Surgical instruments are tracked in physical space using an active optical tracking system. Several of the different registration algorithms were developed with a library of robust math kernel functions, and the accuracy of all registration techniques was thoroughly investigated. Our display was developed using the Win32 API for windows management and tomographic visualization, a frame grabber for live video capture, and OpenGL for visualization of surface renderings. We have begun to use this current implementation of our system for several surgical procedures, including open and minimally invasive liver surgery.

  18. Glenohumeral joint injection: a comparative study of ultrasound and fluoroscopically guided techniques before MR arthrography.

    PubMed

    Rutten, Matthieu J C M; Collins, James M P; Maresch, Bas J; Smeets, Jacques H J M; Janssen, Caroline M M; Kiemeney, Lambertus A L M; Jager, Gerrit J

    2009-03-01

    To assess the variability in accuracy of contrast media introduction, leakage, required time and patient discomfort in four different centres, each using a different image-guided glenohumeral injection technique. Each centre included 25 consecutive patients. The ultrasound-guided anterior (USa) and posterior approach (USp), fluoroscopic-guided anterior (FLa) and posterior (FLp) approach were used. Number of injection attempts, effect of contrast leakage on diagnostic quality, and total room, radiologist and procedure times were measured. Pain was documented with a visual analogue scale (VAS) pain score. Access to the joint was achieved in all patients. A successful first attempt significantly occurred more often with US (94%) than with fluoroscopic guidance (72%). Leakage of contrast medium did not cause interpretative difficulties. With US guidance mean room, procedure and radiologist times were significantly shorter (p < 0.001). The USa approach was rated with the lowest pre- and post-injection VAS scores. The four image-guided injection techniques are successful in injection of contrast material into the glenohumeral joint. US-guided injections and especially the anterior approach are significantly less time consuming, more successful on the first attempt, cause less patient discomfort and obviate the need for radiation and iodine contrast.

  19. Line fiducial material and thickness considerations for ultrasound calibration

    NASA Astrophysics Data System (ADS)

    Ameri, Golafsoun; McLeod, A. J.; Baxter, John S. H.; Chen, Elvis C. S.; Peters, Terry M.

    2015-03-01

    Ultrasound calibration is a necessary procedure in many image-guided interventions, relating the position of tools and anatomical structures in the ultrasound image to a common coordinate system. This is a necessary component of augmented reality environments in image-guided interventions as it allows for a 3D visualization where other surgical tools outside the imaging plane can be found. Accuracy of ultrasound calibration fundamentally affects the total accuracy of this interventional guidance system. Many ultrasound calibration procedures have been proposed based on a variety of phantom materials and geometries. These differences lead to differences in representation of the phantom on the ultrasound image which subsequently affect the ability to accurately and automatically segment the phantom. For example, taut wires are commonly used as line fiducials in ultrasound calibration. However, at large depths or oblique angles, the fiducials appear blurred and smeared in ultrasound images making it hard to localize their cross-section with the ultrasound image plane. Intuitively, larger diameter phantoms with lower echogenicity are more accurately segmented in ultrasound images in comparison to highly reflective thin phantoms. In this work, an evaluation of a variety of calibration phantoms with different geometrical and material properties for the phantomless calibration procedure was performed. The phantoms used in this study include braided wire, plastic straws, and polyvinyl alcohol cryogel tubes with different diameters. Conventional B-mode and synthetic aperture images of the phantoms at different positions were obtained. The phantoms were automatically segmented from the ultrasound images using an ellipse fitting algorithm, the centroid of which is subsequently used as a fiducial for calibration. Calibration accuracy was evaluated for these procedures based on the leave-one-out target registration error. It was shown that larger diameter phantoms with lower echogenicity are more accurately segmented in comparison to highly reflective thin phantoms. This improvement in segmentation accuracy leads to a lower fiducial localization error, which ultimately results in low target registration error. This would have a profound effect on calibration procedures and the feasibility of different calibration procedures in the context of image-guided procedures.

  20. Performance characteristics of an interventional multispectral photoacoustic imaging system for guiding minimally invasive procedures

    PubMed Central

    Mari, Jean Martial; West, Simeon J.; Pratt, Rosalind; David, Anna L.; Ourselin, Sebastien; Beard, Paul C.; Desjardins, Adrien E.

    2016-01-01

    Precise device guidance is important for interventional procedures in many different clinical fields including fetal medicine, regional anesthesia, interventional pain management, and interventional oncology. While ultrasound is widely used in clinical practice for real-time guidance, the image contrast that it provides can be insufficient for visualizing tissue structures such as blood vessels, nerves, and tumors. This study was centered on the development of a photoacoustic imaging system for interventional procedures that delivered excitation light in the ranges of 750 to 900 nm and 1150 to 1300 nm, with an optical fiber positioned in a needle cannula. Coregistered B-mode ultrasound images were obtained. The system, which was based on a commercial ultrasound imaging scanner, has an axial resolution in the vicinity of 100 μm and a submillimeter, depth-dependent lateral resolution. Using a tissue phantom and 800 nm excitation light, a simulated blood vessel could be visualized at a maximum distance of 15 mm from the needle tip. Spectroscopic contrast for hemoglobin and lipids was observed with ex vivo tissue samples, with photoacoustic signal maxima consistent with the respective optical absorption spectra. The potential for further optimization of the system is discussed. PMID:26263417

  1. Heuristic estimation of electromagnetically tracked catheter shape for image-guided vascular procedures

    NASA Astrophysics Data System (ADS)

    Mefleh, Fuad N.; Baker, G. Hamilton; Kwartowitz, David M.

    2014-03-01

    In our previous work we presented a novel image-guided surgery (IGS) system, Kit for Navigation by Image Focused Exploration (KNIFE).1,2 KNIFE has been demonstrated to be effective in guiding mock clinical procedures with the tip of an electromagnetically tracked catheter overlaid onto a pre-captured bi-plane fluoroscopic loop. Representation of the catheter in KNIFE differs greatly from what is captured by the fluoroscope, due to distortions and other properties of fluoroscopic images. When imaged by a fluoroscope, catheters can be visualized due to the inclusion of radiopaque materials (i.e. Bi, Ba, W) in the polymer blend.3 However, in KNIFE catheter location is determined using a single tracking seed located in the catheter tip that is represented as a single point overlaid on pre-captured fluoroscopic images. To bridge the gap in catheter representation between KNIFE and traditional methods we constructed a catheter with five tracking seeds positioned along the distal 70 mm of the catheter. We have currently investigated the use of four spline interpolation methods for estimation of true catheter shape and have assesed the error in their estimation of true catheter shape. In this work we present a method for the evaluation of interpolation algorithms with respect to catheter shape determination.

  2. Ergonomic task analysis of ultrasound-guided femoral nerve block: a pilot study.

    PubMed

    Ajmal, Muhammad; Power, Susan; Smith, Tim; Shorten, George D

    2011-02-01

    To apply ergonomic task analysis to the performance of ultrasound-guided (US-guided) femoral nerve block (FNB) in an acute hospital setting. Pilot prospective observational study. Orthopedic operating room of a regional trauma hospital. 15 anesthesiologists of various levels of experience in US-guided FNB (estimated minimum experience < 10 procedures; maximum about 50 procedures, and from basic trainees to consultants); and 15 patients (5 men and 10 women), aged 77 ± 15 (mean ± SD yrs) years. MEASUREMENTS/OBSERVATIONS: A data capture "tool", which was modified from one previously developed for ergonomic study of spinal anesthesia, was studied. Patient, operator, and heterogeneous environmental factors related to ergonomic performance of US-guided FNB were identified. The observation period started immediately before commencement of positioning the patient and ended on completion of perineural injection. Data were acquired using direct observations, photography, and application of a questionnaire. The quality of ergonomic performance was generally suboptimal and varied greatly among operators. Eight (experience < 10 procedures) of 15 operators excessively rotated their head, neck, and/or back to visualize the image on the ultrasound machine. Eight operators (experience < 10 procedures) performed the procedure with excessive thoracolumbar flexion. Performance of US-guided FNB presents ergonomic challenges and was suboptimal during most of the procedures observed. Formal training in US-guided peripheral nerve blockade should include reference to ergonomic factors. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Multispectral tissue characterization for intestinal anastomosis optimization.

    PubMed

    Cha, Jaepyeong; Shademan, Azad; Le, Hanh N D; Decker, Ryan; Kim, Peter C W; Kang, Jin U; Krieger, Axel

    2015-10-01

    Intestinal anastomosis is a surgical procedure that restores bowel continuity after surgical resection to treat intestinal malignancy, inflammation, or obstruction. Despite the routine nature of intestinal anastomosis procedures, the rate of complications is high. Standard visual inspection cannot distinguish the tissue subsurface and small changes in spectral characteristics of the tissue, so existing tissue anastomosis techniques that rely on human vision to guide suturing could lead to problems such as bleeding and leakage from suturing sites. We present a proof-of-concept study using a portable multispectral imaging (MSI) platform for tissue characterization and preoperative surgical planning in intestinal anastomosis. The platform is composed of a fiber ring light-guided MSI system coupled with polarizers and image analysis software. The system is tested on ex vivo porcine intestine tissue, and we demonstrate the feasibility of identifying optimal regions for suture placement.

  4. Multispectral tissue characterization for intestinal anastomosis optimization

    PubMed Central

    Cha, Jaepyeong; Shademan, Azad; Le, Hanh N. D.; Decker, Ryan; Kim, Peter C. W.; Kang, Jin U.; Krieger, Axel

    2015-01-01

    Abstract. Intestinal anastomosis is a surgical procedure that restores bowel continuity after surgical resection to treat intestinal malignancy, inflammation, or obstruction. Despite the routine nature of intestinal anastomosis procedures, the rate of complications is high. Standard visual inspection cannot distinguish the tissue subsurface and small changes in spectral characteristics of the tissue, so existing tissue anastomosis techniques that rely on human vision to guide suturing could lead to problems such as bleeding and leakage from suturing sites. We present a proof-of-concept study using a portable multispectral imaging (MSI) platform for tissue characterization and preoperative surgical planning in intestinal anastomosis. The platform is composed of a fiber ring light-guided MSI system coupled with polarizers and image analysis software. The system is tested on ex vivo porcine intestine tissue, and we demonstrate the feasibility of identifying optimal regions for suture placement. PMID:26440616

  5. Evaluation of methods to produce an image library for automatic patient model localization for dose mapping during fluoroscopically guided procedures

    NASA Astrophysics Data System (ADS)

    Kilian-Meneghin, Josh; Xiong, Z.; Rudin, S.; Oines, A.; Bednarek, D. R.

    2017-03-01

    The purpose of this work is to evaluate methods for producing a library of 2D-radiographic images to be correlated to clinical images obtained during a fluoroscopically-guided procedure for automated patient-model localization. The localization algorithm will be used to improve the accuracy of the skin-dose map superimposed on the 3D patient- model of the real-time Dose-Tracking-System (DTS). For the library, 2D images were generated from CT datasets of the SK-150 anthropomorphic phantom using two methods: Schmid's 3D-visualization tool and Plastimatch's digitally-reconstructed-radiograph (DRR) code. Those images, as well as a standard 2D-radiographic image, were correlated to a 2D-fluoroscopic image of a phantom, which represented the clinical-fluoroscopic image, using the Corr2 function in Matlab. The Corr2 function takes two images and outputs the relative correlation between them, which is fed into the localization algorithm. Higher correlation means better alignment of the 3D patient-model with the patient image. In this instance, it was determined that the localization algorithm will succeed when Corr2 returns a correlation of at least 50%. The 3D-visualization tool images returned 55-80% correlation relative to the fluoroscopic-image, which was comparable to the correlation for the radiograph. The DRR images returned 61-90% correlation, again comparable to the radiograph. Both methods prove to be sufficient for the localization algorithm and can be produced quickly; however, the DRR method produces more accurate grey-levels. Using the DRR code, a library at varying angles can be produced for the localization algorithm.

  6. Truly hybrid interventional MR/X-ray system: investigation of in vivo applications.

    PubMed

    Fahrig, R; Butts, K; Wen, Z; Saunders, R; Kee, S T; Sze, D Y; Daniel, B L; Laerum, F; Pelc, N J

    2001-12-01

    The purpose of this study was to provide in vivo demonstrations of the functionality of a truly hybrid interventional x-ray/magnetic resonance (MR) system. A digital flat-panel x-ray system (1,024(2) array of 200 microm pixels, 30 frames per second) was integrated into an interventional 0.5-T magnet. The hybrid system is capable of MR and x-ray imaging of the same field of view without patient movement. Two intravascular procedures were performed in a 22-kg porcine model: placement of a transjugular intrahepatic portosystemic shunt (TIPS) (x-ray-guided catheterization of the hepatic vein, MR fluoroscopy-guided portal puncture, and x-ray-guided stent placement) and mock chemoembolization (x-ray-guided subselective catheterization of a renal artery branch and MR evaluation of perfused volume). The resolution and frame rate of the x-ray fluoroscopy images were sufficient to visualize and place devices, including nitinol guidewires (0.016-0.035-inch diameter) and stents and a 2.3-F catheter. Fifth-order branches of the renal artery could be seen. The quality of both real-time (3.5 frames per second) and standard MR images was not affected by the x-ray system. During MR-guided TIPS placement, the trocar and the portal vein could be easily visualized, allowing successful puncture from hepatic to portal vein. Switching back and forth between x-ray and MR imaging modalities without requiring movement of the patient was demonstrated. The integrated nature of the system could be especially beneficial when x-ray and MR image guidance are used iteratively.

  7. Improving Performance During Image-Guided Procedures

    PubMed Central

    Duncan, James R.; Tabriz, David

    2015-01-01

    Objective Image-guided procedures have become a mainstay of modern health care. This article reviews how human operators process imaging data and use it to plan procedures and make intraprocedural decisions. Methods A series of models from human factors research, communication theory, and organizational learning were applied to the human-machine interface that occupies the center stage during image-guided procedures. Results Together, these models suggest several opportunities for improving performance as follows: 1. Performance will depend not only on the operator’s skill but also on the knowledge embedded in the imaging technology, available tools, and existing protocols. 2. Voluntary movements consist of planning and execution phases. Performance subscores should be developed that assess quality and efficiency during each phase. For procedures involving ionizing radiation (fluoroscopy and computed tomography), radiation metrics can be used to assess performance. 3. At a basic level, these procedures consist of advancing a tool to a specific location within a patient and using the tool. Paradigms from mapping and navigation should be applied to image-guided procedures. 4. Recording the content of the imaging system allows one to reconstruct the stimulus/response cycles that occur during image-guided procedures. Conclusions When compared with traditional “open” procedures, the technology used during image-guided procedures places an imaging system and long thin tools between the operator and the patient. Taking a step back and reexamining how information flows through an imaging system and how actions are conveyed through human-machine interfaces suggest that much can be learned from studying system failures. In the same way that flight data recorders revolutionized accident investigations in aviation, much could be learned from recording video data during image-guided procedures. PMID:24921628

  8. Image registration: enabling technology for image guided surgery and therapy.

    PubMed

    Sauer, Frank

    2005-01-01

    Imaging looks inside the patient's body, exposing the patient's anatomy beyond what is visible on the surface. Medical imaging has a very successful history for medical diagnosis. It also plays an increasingly important role as enabling technology for minimally invasive procedures. Interventional procedures (e.g. catheter based cardiac interventions) are traditionally supported by intra-procedure imaging (X-ray fluoro, ultrasound). There is realtime feedback, but the images provide limited information. Surgical procedures are traditionally supported with pre-operative images (CT, MR). The image quality can be very good; however, the link between images and patient has been lost. For both cases, image registration can play an essential role -augmenting intra-op images with pre-op images, and mapping pre-op images to the patient's body. We will present examples of both approaches from an application oriented perspective, covering electrophysiology, radiation therapy, and neuro-surgery. Ultimately, as the boundaries between interventional radiology and surgery are becoming blurry, also the different methods for image guidance will merge. Image guidance will draw upon a combination of pre-op and intra-op imaging together with magnetic or optical tracking systems, and enable precise minimally invasive procedures. The information is registered into a common coordinate system, and allows advanced methods for visualization such as augmented reality or advanced methods for therapy delivery such as robotics.

  9. Iatrogenic submucosal tunnel in the ureter: a rare complication during advancement of the guide wire.

    PubMed

    El Darawany, Hamed; Barakat, Alaa; Madi, Maha Al; Aldamanhori, Reem; Al Otaibi, Khalid; Al-Zahrani, Ali A

    2016-01-01

    Inserting a guide wire is a common practice during endo-urological procedures. A rare complication in patients with ureteral stones where an iatrogenic submucosal tunnel (IST) is created during endoscopic guide wire placement. Summarize data on IST. Retrospective descriptive study of patients treated from from October 2009 until January 2015. King Fahd Hospital of the University, Al-Khobar, Saudi Arabia. Patients with ureteral stones were divided to 2 groups. In group I (335 patients), the ureteral stones were removed by ureteroscopy in one stage. Group II (97 patients) had a 2-staged procedure starting with a double J-stent placement for kidney drainage followed within 3 weeks with ureteroscopic stone removal. Endoscopic visualization of ureteric submucosal tunneling by guide wire. IST occurred in 9/432 patients with ureteral stones (2.1%). The diagnosis in group I was made during ureteroscopy by direct visualization of a vanishing guide wire at the level of the stone (6 patients). In group II, IST was suspected when renal pain was not relieved after placement of the double J-stent or if imaging by ultrasound or intravenous urography showed persistent back pressure to the obstructed kidney (3 patients). The condition was subsequently confirmed by ureteroscopy. Forceful advancement of the guide wire in an inflamed and edematous ureteral segment impacted by a stone is probably the triggering factor for development of IST. Definitive diagnosis is possible only by direct visualization during ureteroscopy. Awareness of this potential complication is important to guard against its occurrence. Relatively small numbers of subjects and the retrospective nature of the study.

  10. Navigational Guidance and Ablation Planning Tools for Interventional Radiology.

    PubMed

    Sánchez, Yadiel; Anvari, Arash; Samir, Anthony E; Arellano, Ronald S; Prabhakar, Anand M; Uppot, Raul N

    Image-guided biopsy and ablation relies on successful identification and targeting of lesions. Currently, image-guided procedures are routinely performed under ultrasound, fluoroscopy, magnetic resonance imaging, or computed tomography (CT) guidance. However, these modalities have their limitations including inadequate visibility of the lesion, lesion or organ or patient motion, compatibility of instruments in an magnetic resonance imaging field, and, for CT and fluoroscopy cases, radiation exposure. Recent advances in technology have resulted in the development of a new generation of navigational guidance tools that can aid in targeting lesions for biopsy or ablations. These navigational guidance tools have evolved from simple hand-held trajectory guidance tools, to electronic needle visualization, to image fusion, to the development of a body global positioning system, to growth in cone-beam CT, and to ablation volume planning. These navigational systems are promising technologies that not only have the potential to improve lesion targeting (thereby increasing diagnostic yield of a biopsy or increasing success of tumor ablation) but also have the potential to decrease radiation exposure to the patient and staff, decrease procedure time, decrease the sedation requirements, and improve patient safety. The purpose of this article is to describe the challenges in current standard image-guided techniques, provide a definition and overview for these next-generation navigational devices, and describe the current limitations of these, still evolving, next-generation navigational guidance tools. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Reliable vision-guided grasping

    NASA Technical Reports Server (NTRS)

    Nicewarner, Keith E.; Kelley, Robert B.

    1992-01-01

    Automated assembly of truss structures in space requires vision-guided servoing for grasping a strut when its position and orientation are uncertain. This paper presents a methodology for efficient and robust vision-guided robot grasping alignment. The vision-guided grasping problem is related to vision-guided 'docking' problems. It differs from other hand-in-eye visual servoing problems, such as tracking, in that the distance from the target is a relevant servo parameter. The methodology described in this paper is hierarchy of levels in which the vision/robot interface is decreasingly 'intelligent,' and increasingly fast. Speed is achieved primarily by information reduction. This reduction exploits the use of region-of-interest windows in the image plane and feature motion prediction. These reductions invariably require stringent assumptions about the image. Therefore, at a higher level, these assumptions are verified using slower, more reliable methods. This hierarchy provides for robust error recovery in that when a lower-level routine fails, the next-higher routine will be called and so on. A working system is described which visually aligns a robot to grasp a cylindrical strut. The system uses a single camera mounted on the end effector of a robot and requires only crude calibration parameters. The grasping procedure is fast and reliable, with a multi-level error recovery system.

  12. High-frequency ultrasound imaging for breast cancer biopsy guidance

    PubMed Central

    Cummins, Thomas; Yoon, Changhan; Choi, Hojong; Eliahoo, Payam; Kim, Hyung Ham; Yamashita, Mary W.; Hovanessian-Larsen, Linda J.; Lang, Julie E.; Sener, Stephen F.; Vallone, John; Martin, Sue E.; Kirk Shung, K.

    2015-01-01

    Abstract. Image-guided core needle biopsy is the current gold standard for breast cancer diagnosis. Microcalcifications, an important radiographic finding on mammography suggestive of early breast cancer such as ductal carcinoma in situ, are usually biopsied under stereotactic guidance. This procedure, however, is uncomfortable for patients and requires the use of ionizing radiation. It would be preferable to biopsy microcalcifications under ultrasound guidance since it is a faster procedure, more comfortable for the patient, and requires no radiation. However, microcalcifications cannot reliably be detected with the current standard ultrasound imaging systems. This study is motivated by the clinical need for real-time high-resolution ultrasound imaging of microcalcifications, so that biopsies can be accurately performed under ultrasound guidance. We have investigated how high-frequency ultrasound imaging can enable visualization of microstructures in ex vivo breast tissue biopsy samples. We generated B-mode images of breast tissue and applied the Nakagami filtering technique to help refine image output so that microcalcifications could be better assessed during ultrasound-guided core biopsies. We describe the preliminary clinical results of high-frequency ultrasound imaging of ex vivo breast biopsy tissue with microcalcifications and without Nakagami filtering and the correlation of these images with the pathology examination by hematoxylin and eosin stain and whole slide digital scanning. PMID:26693167

  13. A novel drill design for photoacoustic guided surgeries

    NASA Astrophysics Data System (ADS)

    Shubert, Joshua; Lediju Bell, Muyinatu A.

    2018-02-01

    Fluoroscopy is currently the standard approach for image guidance of surgical drilling procedures. In addition to the harmful radiation dose to the patient and surgeon, fluoroscopy fails to visualize critical structures such as blood vessels and nerves within the drill path. Photoacoustic imaging is a well-suited imaging method to visualize these structures and it does not require harmful ionizing radiation. However, there is currently no clinical system available to deliver light to occluded drill bit tips. To address this challenge, a prototype drill was designed, built, and tested using an internal light delivery system that allows laser energy to be transferred from a stationary laser source to the tip of a spinning drill bit. Photoacoustic images were successfully obtained with the drill bit submerged in water and with the drill tip inserted into a thoracic vertebra from a human cadaver.

  14. A Single-Institution Experience in Percutaneous Image-Guided Biopsy of Malignant Pleural Mesothelioma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Welch, B. T., E-mail: Welch.brian@mayo.edu; Eiken, P. W.; Atwell, T. D.

    PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneousmore » image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.« less

  15. [Laparoscopic and general surgery guided by open interventional magnetic resonance].

    PubMed

    Lauro, A; Gould, S W T; Cirocchi, R; Giustozzi, G; Darzi, A

    2004-10-01

    Interventional magnetic resonance (IMR) machines have produced unique opportunity for image-guided surgery. The open configuration design and fast pulse sequence allow virtual real time intraoperative scanning to monitor the progress of a procedure, with new images produced every 1.5 sec. This may give greater appreciation of anatomy, especially deep to the 2-dimensional laparoscopic image, and hence increase safety, reduce procedure magnitude and increase confidence in tumour resection surgery. The aim of this paper was to investigate the feasibility of performing IMR-image-guided general surgery, especially in neoplastic and laparoscopic field, reporting a single center -- St. Mary's Hospital (London, UK) -- experience. Procedures were carried out in a Signa 0.5 T General Elettric SP10 Interventional MR (General Electric Medical Systems, Milwaukee, WI, USA) with magnet-compatible instruments (titanium alloy instruments, plastic retractors and ultrasonic driven scalpel) and under general anesthesia. There were performed 10 excision biopsies of palpable benign breast tumors (on female patients), 3 excisions of skin sarcoma (dermatofibrosarcoma protuberans), 1 right hemicolectomy and 2 laparoscopic cholecystectomies. The breast lesions were localized with pre- and postcontrast (intravenous gadolinium DPTA) sagittal and axial fast multiplanar spoiled gradient recalled conventional Signa sequences; preoperative real time fast gradient recalled sequences were also obtained using the flashpoint tracking device. During right hemicolectomy intraoperative single shot fast spin echo (SSFSE) and fast spoiled gradient recalled (FSPGR) imaging of right colon were performed after installation of 150 cc of water or 1% gadolinium solution, respectively, through a Foley catheter; imaging was also obtained in an attempt to identify mesenteric lymph nodes intraoperatively. Concerning laparoscopic procedures, magnetic devices (insufflator, light source) were positioned outside scan room, the tubing and light head being passed through penetration panels. Intraoperative MR-cholangiography was performed using fast spin echo (SSFSE) techniques with minimal intensity projection 3-dimensional reconstruction. About skin sarcomas, 2 of them were skin recurrences of previously surgically treated sarcomas (all of them received preoperative biopsy) and the extent of the lesion was then determined using short tau inversion recovery (STIR) sequence. The skin was closed in each case without need for any plastic reconstruction. The breast lesions were visualized with both Signa and real-time imaging and all enhanced with contrast: 2 (20%) were visualized only after contrast enhancement; intraoperative real time imaging clearly demonstrated a resection margin in all cases. Maximum dimensions of breast specimens (range 8-50 mm, median 24.5 mm) were not significantly different from those measured by Signa (p>0.17, Student's paired t-test) or real time images (p>0.4): also there was no significant difference in lesion size between Signa and real time images (p>0.25). All postprocedure scans clearly demonstrated complete excision. The extent of the tumor at MR imaging was greater in each case than suggested by clinical examination. Adequate resection margins were planned using STIR sequences. Histological examination confirmed clear surgical margins of at least 1 cm in each case. During right hemicolectomy, both intraoperative SSFSE and FSPGR contrast imaging revealed the lesion and details of the colonic surface; imaging of the lymph node draining right colon was only partially successful, due to movement artifact. Concerning laparoscopic procedures, both FSE and SSFSE techniques produced reasonable images of the gallbladder and intrahepatic ducts, but the FSE imaging was of poor quality due to respiration artifact; however, SSFSE allowed visualization of the gallbladder and part of the common bile duct. About skin sarcomas, the extent of the tumor at MR imaging was greater in each case than suggested by clinical examination and in each case the complete tumor excision was confirmed. Histological examination confirmed clear surgical margins of at least 1 cm in each case. Intraoperative MR scanning reliably identifies palpable breast tumours and skin sarcomas and is sufficiently accurate to guide their surgical excision. Further work may be done to develop laparoscopic and open abdominal surgery as well.

  16. Computer-based System for the Virtual-Endoscopic Guidance of Bronchoscopy.

    PubMed

    Helferty, J P; Sherbondy, A J; Kiraly, A P; Higgins, W E

    2007-11-01

    The standard procedure for diagnosing lung cancer involves two stages: three-dimensional (3D) computed-tomography (CT) image assessment, followed by interventional bronchoscopy. In general, the physician has no link between the 3D CT image assessment results and the follow-on bronchoscopy. Thus, the physician essentially performs bronchoscopic biopsy of suspect cancer sites blindly. We have devised a computer-based system that greatly augments the physician's vision during bronchoscopy. The system uses techniques from computer graphics and computer vision to enable detailed 3D CT procedure planning and follow-on image-guided bronchoscopy. The procedure plan is directly linked to the bronchoscope procedure, through a live registration and fusion of the 3D CT data and bronchoscopic video. During a procedure, the system provides many visual tools, fused CT-video data, and quantitative distance measures; this gives the physician considerable visual feedback on how to maneuver the bronchoscope and where to insert the biopsy needle. Central to the system is a CT-video registration technique, based on normalized mutual information. Several sets of results verify the efficacy of the registration technique. In addition, we present a series of test results for the complete system for phantoms, animals, and human lung-cancer patients. The results indicate that not only is the variation in skill level between different physicians greatly reduced by the system over the standard procedure, but that biopsy effectiveness increases.

  17. Improving both imaging speed and spatial resolution in MR-guided neurosurgery

    NASA Astrophysics Data System (ADS)

    Liu, Haiying; Hall, Walter A.; Truwit, Charles L.

    2002-05-01

    A robust near real-time MRI based surgical guidance scheme has been developed and used in neurosurgical procedure performed in our combined 1.5 Tesla MR operating room. Because of the increased susceptibility difference in the area of surgical site during surgery, the preferred real- time imaging technique is a single shot imaging sequence based on the concept of the half acquisition with turbo spin echoes (HASTE). In order to maintain sufficient spatial resolution for visualizing the surgical devices, such as a biopsy needle and catheter, we used focused field of view (FOV) in the phase-encoding (PE) direction coupled with an out-volume signal suppression (OVS) technique. The key concept of the method is to minimize the total number of the required phase encoding steps and the effective echo time (TE) as well as the longest TE for the high spatial encoding step. The concept has been first demonstrated with a phantom experiment, which showed when the water was doped with Gd- DTPA to match the relaxation rates of the brain tissue there was a significant spatial blurring primarily along the phase encoding direction if the conventional HASTE technique, and the new scheme indeed minimized the spatial blur in the resulting image and improved the needle visualization as anticipated. Using the new scheme in a typical MR-guided neurobiopsy procedure, the brain biopsy needle was easily seen against the tissue background with minimal blurring due the inevitable T2 signal decay even when the PE direction was set parallel to the needle axis. This MR based guidance technique has practically allowed neurosurgeons to visualize the biopsy needle and to monitor its insertion with a better certainty at near real-time pace.

  18. Interventional spinal procedures guided and controlled by a 3D rotational angiographic unit.

    PubMed

    Pedicelli, Alessandro; Verdolotti, Tommaso; Pompucci, Angelo; Desiderio, Flora; D'Argento, Francesco; Colosimo, Cesare; Bonomo, Lorenzo

    2011-12-01

    The aim of this paper is to demonstrate the usefulness of 2D multiplanar reformatting images (MPR) obtained from rotational acquisitions with cone-beam computed tomography technology during percutaneous extra-vascular spinal procedures performed in the angiography suite. We used a 3D rotational angiographic unit with a flat panel detector. MPR images were obtained from a rotational acquisition of 8 s (240 images at 30 fps), tube rotation of 180° and after post-processing of 5 s by a local work-station. Multislice CT (MSCT) is the best guidance system for spinal approaches permitting direct tomographic visualization of each spinal structure. Many operators, however, are trained with fluoroscopy, it is less expensive, allows real-time guidance, and in many centers the angiography suite is more frequently available for percutaneous procedures. We present our 6-year experience in fluoroscopy-guided spinal procedures, which were performed under different conditions using MPR images. We illustrate cases of vertebroplasty, epidural injections, selective foraminal nerve root block, facet block, percutaneous treatment of disc herniation and spine biopsy, all performed with the help of MPR images for guidance and control in the event of difficult or anatomically complex access. The integrated use of "CT-like" MPR images allows the execution of spinal procedures under fluoroscopy guidance alone in all cases of dorso-lumbar access, with evident limitation of risks and complications, and without need for recourse to MSCT guidance, thus eliminating CT-room time (often bearing high diagnostic charges), and avoiding organizational problems for procedures that need, for example, combined use of a C-arm in the CT room.

  19. Post-processing methods of rendering and visualizing 3-D reconstructed tomographic images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wong, S.T.C.

    The purpose of this presentation is to discuss the computer processing techniques of tomographic images, after they have been generated by imaging scanners, for volume visualization. Volume visualization is concerned with the representation, manipulation, and rendering of volumetric data. Since the first digital images were produced from computed tomography (CT) scanners in the mid 1970s, applications of visualization in medicine have expanded dramatically. Today, three-dimensional (3D) medical visualization has expanded from using CT data, the first inherently digital source of 3D medical data, to using data from various medical imaging modalities, including magnetic resonance scanners, positron emission scanners, digital ultrasound,more » electronic and confocal microscopy, and other medical imaging modalities. We have advanced from rendering anatomy to aid diagnosis and visualize complex anatomic structures to planning and assisting surgery and radiation treatment. New, more accurate and cost-effective procedures for clinical services and biomedical research have become possible by integrating computer graphics technology with medical images. This trend is particularly noticeable in current market-driven health care environment. For example, interventional imaging, image-guided surgery, and stereotactic and visualization techniques are now stemming into surgical practice. In this presentation, we discuss only computer-display-based approaches of volumetric medical visualization. That is, we assume that the display device available is two-dimensional (2D) in nature and all analysis of multidimensional image data is to be carried out via the 2D screen of the device. There are technologies such as holography and virtual reality that do provide a {open_quotes}true 3D screen{close_quotes}. To confine the scope, this presentation will not discuss such approaches.« less

  20. Advanced Imaging Catheter: Final Project Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krulevitch, P; Colston, B; DaSilva, L

    2001-07-20

    Minimally invasive surgery (MIS) is an approach whereby procedures conventionally performed with large and potentially traumatic incisions are replaced by several tiny incisions through which specialized instruments are inserted. Early MIS, often called laparoscopic surgery, used video cameras and laparoscopes to visualize and control the medical devices, which were typically cutting or stapling tools. More recently, catheter-based procedures have become a fast growing sector of all surgeries. In these procedures, small incisions are made into one of the main arteries (e.g. femoral artery in the thigh), and a long thin hollow tube is inserted and positioned near the target area.more » The key advantage of this technique is that recovery time can be reduced from months to a matter of days. In the United States, over 700,000 catheter procedures are performed annually representing a market of over $350 million. Further growth in this area will require significant improvements in the current catheter technology. In order to effectively navigate a catheter through the tortuous vessels of the body, two capabilities must exist: imaging and positioning. In most cases, catheter procedures rely on radiography for visualization and manual manipulation for positioning of the device. Radiography provides two-dimensional, global images of the vasculature and cannot be used continuously due to radiation exposure to both the patient and physician. Intravascular ultrasound devices are available for continuous local imaging at the catheter tip, but these devices cannot be used simultaneously with therapeutic devices. Catheters are highly compliant devices, and manipulating the catheter is similar to pushing on a string. Often, a guide wire is used to help position the catheter, but this procedure has its own set of problems. Three characteristics are used to describe catheter maneuverability: (1) pushability -- the amount of linear displacement of the distal end (inside body) relative to an applied displacement of the proximal end (outside body); (2) torquability -- the amount of rotation of the distal end relative to an applied rotation of the proximal end; and (3) trackability -- the extent to which the catheter tracks along the guide wire without displacing it.« less

  1. Ultrasound-ultrasound image overlay fusion improves real-time control of radiofrequency ablation margin in the treatment of hepatocellular carcinoma.

    PubMed

    Minami, Yasunori; Minami, Tomohiro; Hagiwara, Satoru; Ida, Hiroshi; Ueshima, Kazuomi; Nishida, Naoshi; Murakami, Takamichi; Kudo, Masatoshi

    2018-05-01

    To assess the clinical feasibility of US-US image overlay fusion with evaluation of the ablative margin in radiofrequency ablation (RFA) for hepatocellular carcinoma (HCC). Fifty-three patients with 68 HCCs measuring 0.9-4.0 cm who underwent RFA guided by US-US overlay image fusion were included in this retrospective study. By an overlay of pre-/postoperative US, the tumor image could be projected onto the ablative hyperechoic zone. Therefore, the ablative margin three-dimensionally could be shown during the RFA procedure. US-US image overlay was compared to dynamic CT a few days after RFA for assessment of early treatment response. Accuracy of graded response was calculated, and the performance of US-US image overlay fusion was compared with that of CT using a Kappa agreement test. Technically effective ablation was achieved in a single session, and 59 HCCs (86.8 %) succeeded in obtaining a 5-mm margin on CT. The response with US-US image overlay correctly predicted early CT evaluation with an accuracy of 92.6 % (63/68) (k = 0.67; 95 % CI: 0.39-0.95). US-US image overlay fusion can be proposed as a feasible guidance in RFA with a safety margin and predicts early response of treatment assessment with high accuracy. • US-US image overlay fusion visualizes the ablative margin during RFA procedure. • Visualizing the margin during the procedure can prompt immediate complementary treatment. • US image fusion correlates with the results of early evaluation CT.

  2. Augmented reality in surgical procedures

    NASA Astrophysics Data System (ADS)

    Samset, E.; Schmalstieg, D.; Vander Sloten, J.; Freudenthal, A.; Declerck, J.; Casciaro, S.; Rideng, Ø.; Gersak, B.

    2008-02-01

    Minimally invasive therapy (MIT) is one of the most important trends in modern medicine. It includes a wide range of therapies in videoscopic surgery and interventional radiology and is performed through small incisions. It reduces hospital stay-time by allowing faster recovery and offers substantially improved cost-effectiveness for the hospital and the society. However, the introduction of MIT has also led to new problems. The manipulation of structures within the body through small incisions reduces dexterity and tactile feedback. It requires a different approach than conventional surgical procedures, since eye-hand co-ordination is not based on direct vision, but more predominantly on image guidance via endoscopes or radiological imaging modalities. ARIS*ER is a multidisciplinary consortium developing a new generation of decision support tools for MIT by augmenting visual and sensorial feedback. We will present tools based on novel concepts in visualization, robotics and haptics providing tailored solutions for a range of clinical applications. Examples from radio-frequency ablation of liver-tumors, laparoscopic liver surgery and minimally invasive cardiac surgery will be presented. Demonstrators were developed with the aim to provide a seamless workflow for the clinical user conducting image-guided therapy.

  3. Magnetic navigation in ultrasound-guided interventional radiology procedures.

    PubMed

    Xu, H-X; Lu, M-D; Liu, L-N; Guo, L-H

    2012-05-01

    To evaluate the usefulness of magnetic navigation in ultrasound (US)-guided interventional procedures. Thirty-seven patients who were scheduled for US-guided interventional procedures (20 liver cancer ablation procedures and 17 other procedures) were included. Magnetic navigation with three-dimensional (3D) computed tomography (CT), magnetic resonance imaging (MRI), 3D US, and position-marking magnetic navigation were used for guidance. The influence on clinical outcome was also evaluated. Magnetic navigation facilitated applicator placement in 15 of 20 ablation procedures for liver cancer in which multiple ablations were performed; enhanced guidance in two small liver cancers invisible on conventional US but visible at CT or MRI; and depicted the residual viable tumour after transcatheter arterial chemoembolization for liver cancer in one procedure. In four of 17 other interventional procedures, position-marking magnetic navigation increased the visualization of the needle tip. Magnetic navigation was beneficial in 11 (55%) of 20 ablation procedures; increased confidence but did not change management in five (25%); added some information but did not change management in two (10%); and made no change in two (10%). In the other 17 interventional procedures, the corresponding numbers were 1 (5.9%), 2 (11.7%), 7 (41.2%), and 7 (41.2%), respectively (p=0.002). Magnetic navigation in US-guided interventional procedure provides solutions in some difficult cases in which conventional US guidance is not suitable. It is especially useful in complicated interventional procedures such as ablation for liver cancer. Copyright © 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  4. Diagnostic radiograph based 3D bone reconstruction framework: application to the femur.

    PubMed

    Gamage, P; Xie, S Q; Delmas, P; Xu, W L

    2011-09-01

    Three dimensional (3D) visualization of anatomy plays an important role in image guided orthopedic surgery and ultimately motivates minimally invasive procedures. However, direct 3D imaging modalities such as Computed Tomography (CT) are restricted to a minority of complex orthopedic procedures. Thus the diagnostics and planning of many interventions still rely on two dimensional (2D) radiographic images, where the surgeon has to mentally visualize the anatomy of interest. The purpose of this paper is to apply and validate a bi-planar 3D reconstruction methodology driven by prominent bony anatomy edges and contours identified on orthogonal radiographs. The results obtained through the proposed methodology are benchmarked against 3D CT scan data to assess the accuracy of reconstruction. The human femur has been used as the anatomy of interest throughout the paper. The novelty of this methodology is that it not only involves the outer contours of the bony anatomy in the reconstruction but also several key interior edges identifiable on radiographic images. Hence, this framework is not simply limited to long bones, but is generally applicable to a multitude of other bony anatomies as illustrated in the results section. Copyright © 2010 Elsevier Ltd. All rights reserved.

  5. Review of intraoperative optical coherence tomography: technology and applications [Invited

    PubMed Central

    Carrasco-Zevallos, Oscar M.; Viehland, Christian; Keller, Brenton; Draelos, Mark; Kuo, Anthony N.; Toth, Cynthia A.; Izatt, Joseph A.

    2017-01-01

    During microsurgery, en face imaging of the surgical field through the operating microscope limits the surgeon’s depth perception and visualization of instruments and sub-surface anatomy. Surgical procedures outside microsurgery, such as breast tumor resections, may also benefit from visualization of the sub-surface tissue structures. The widespread clinical adoption of optical coherence tomography (OCT) in ophthalmology and its growing prominence in other fields, such as cancer imaging, has motivated the development of intraoperative OCT for real-time tomographic visualization of surgical interventions. This article reviews key technological developments in intraoperative OCT and their applications in human surgery. We focus on handheld OCT probes, microscope-integrated OCT systems, and OCT-guided laser treatment platforms designed for intraoperative use. Moreover, we discuss intraoperative OCT adjuncts and processing techniques currently under development to optimize the surgical feedback derivable from OCT data. Lastly, we survey salient clinical studies of intraoperative OCT for human surgery. PMID:28663853

  6. Real-time self-calibration of a tracked augmented reality display

    NASA Astrophysics Data System (ADS)

    Baum, Zachary; Lasso, Andras; Ungi, Tamas; Fichtinger, Gabor

    2016-03-01

    PURPOSE: Augmented reality systems have been proposed for image-guided needle interventions but they have not become widely used in clinical practice due to restrictions such as limited portability, low display refresh rates, and tedious calibration procedures. We propose a handheld tablet-based self-calibrating image overlay system. METHODS: A modular handheld augmented reality viewbox was constructed from a tablet computer and a semi-transparent mirror. A consistent and precise self-calibration method, without the use of any temporary markers, was designed to achieve an accurate calibration of the system. Markers attached to the viewbox and patient are simultaneously tracked using an optical pose tracker to report the position of the patient with respect to a displayed image plane that is visualized in real-time. The software was built using the open-source 3D Slicer application platform's SlicerIGT extension and the PLUS toolkit. RESULTS: The accuracy of the image overlay with image-guided needle interventions yielded a mean absolute position error of 0.99 mm (95th percentile 1.93 mm) in-plane of the overlay and a mean absolute position error of 0.61 mm (95th percentile 1.19 mm) out-of-plane. This accuracy is clinically acceptable for tool guidance during various procedures, such as musculoskeletal injections. CONCLUSION: A self-calibration method was developed and evaluated for a tracked augmented reality display. The results show potential for the use of handheld image overlays in clinical studies with image-guided needle interventions.

  7. Intrapericardial echocardiography: a novel catheter-based approach to cardiac imaging.

    PubMed

    Rodrigues, Ana Clara Tude; d'Avila, Andre; Houghtaling, Christopher; Ruskin, Jeremy N; Picard, Michael; Reddy, Vivek Y

    2004-03-01

    Transvascular catheter-based intracardiac echocardiography has been successfully used to help guide catheter ablation and electrophysiologic procedures. It has recently been demonstrated that catheters can be safely placed into the pericardial space to allow for epicardial cardiac mapping and ablation. We evaluated the feasibility of catheter-based intrapericardial echocardiography (IPE) during such procedures to identify cardiac structures and visualize intracardiac catheters. IPE was performed in 7 goats by placing a phased-array ultrasound transducer contained within a 10F steerable catheter into the pericardial space using the same transthoracic subxyphoid approach as used to map and ablate epicardial ventricular tachycardia. Images were obtained of cardiac structures and of intracardiac ablation catheters. After the procedure, the hearts were harvested to assess for possible IPE-related lesions. The IPE catheter could be easily placed inside the pericardial space in all animals. In 7 of 7 cases, longitudinal and short-axis views of right- and left-sided chambers and valves were obtained, similar in orientation to transesophageal echocardiography. Visualization of atrial appendages (6/7), pulmonary veins (6/7), coronary arteries (6/7), and coronary sinus (3/6) was also feasible. Assessment of intracardiac transvalvar and venous blood flow was achieved by spectral and color Doppler. The ablation catheter could be clearly visualized inside cardiac chambers. No arrhythmias were induced with IPE catheter manipulation. After harvesting the hearts, no lesions resulting from the procedure were observed. In this experimental setting, IPE was able to provide detailed images of cardiac structures and establish the relative position of the ablation catheter.

  8. Optimizing brain tumor resection. Midfield interventional MR imaging.

    PubMed

    Alexander, E

    2001-11-01

    The development of the intraoperative MR imager represents an important example of creative vision and interdisciplinary teamwork. The result is a remarkable tool for neurosurgical applications. MRT allows surgical manipulation under direct visualization of the intracranial contents through the eye of the surgeon and through the volumetric images of the MR imaging system. This technology can be applied to cranial and spinal cases, and forseeably can encompass application to the entire gamut of neurosurgical efforts. The author's experience has been that this device is easy and comfortable for the surgeon to use. Image acquisition, giving views in the plane of choice, lasts no more than 2 to 60 seconds (depending on the imaging method), and does not increase the duration of a given procedure substantially. The author believes that the information received through intraoperative MR imaging scanning ultimately will contribute to decreasing the duration of surgery. Future possibilities include combining the intraoperative MR imager with other technologies, such as the endoscope, focused ultrasound, robotics, and the evaluation of brain function intraoperatively. The development of the intraoperative MR imager marks a significant advance in neurosurgery, an advance that will revolutionize intraoperative visualization as fully as the operating microscope. The combination of intraoperative visualization and precise surgical navigation is unparalleled, and its enhancement of surgical applications will be widespread. Considering the remarkable potential of the intraoperative MR imager for neurosurgical applications, optimal magnet design, image quality, and navigational methods are necessary to capitalize on the advantages of this revolutionary tool. The intraoperative MR imaging system that the author's team has developed and used has combined these features, and allows the performance of open surgical procedures without the need of patient or magnet repositioning. By using advanced navigational tools and computer technology, it represents an integration of frameless stereotactic methods with real-time interactive imaging. The midfield imager provides sufficient spatial and temporal resolution and image quality to assess anatomy and pathology adequately, to monitor a surgical procedure, and make image-based decisions. The intraoperative use of this unique system is not limited to biopsies or limited-access procedures. The entire range of neurosurgical procedures can be performed, if the requisite instrumentation is available. Much work remains to be done, however. The team did not develop this system only to enable the performance of current neurosurgical procedures. Forty years ago, the operating microscope enabled not only the performance of undreamt-of procedures but opened the door to entire new subspecialties. The entire landscape of neurosurgery will change at a fundamental level as the full ramifications of this exciting idea come to fruition. The holy grail of image-guided surgery is a seamless interface between the eye and hand in the purest sense (i.e., the mind's eye and hand). Ideally, this seamless interface represents effortless flow between the procedural goal compared with the present situation and the manipulation of the tools available to accomplish the task, whether they be the scalpel, drill, laser, ultrasonic aspirator, phased array focused ultrasound, microrobot, or high-dose irradiator. As in the realm of high-performance military jet fighters, the physical limits of the human being demarcate the confining boundary of the system. Those limits are much tighter around the domain of tool manipulation, where the surgeon will yield, early on, to the enhanced performance of robotics and other technical adjuncts. The era of large open magnet imaging systems for surgical procedures then will come to a close; however, the grander era of the surgeon's integration of precision-guided, multimodality therapeutics will just be beginning. The future will be very bright, indeed.

  9. Fully automatic three-dimensional visualization of intravascular optical coherence tomography images: methods and feasibility in vivo

    PubMed Central

    Ughi, Giovanni J; Adriaenssens, Tom; Desmet, Walter; D’hooge, Jan

    2012-01-01

    Intravascular optical coherence tomography (IV-OCT) is an imaging modality that can be used for the assessment of intracoronary stents. Recent publications pointed to the fact that 3D visualizations have potential advantages compared to conventional 2D representations. However, 3D imaging still requires a time consuming manual procedure not suitable for on-line application during coronary interventions. We propose an algorithm for a rapid and fully automatic 3D visualization of IV-OCT pullbacks. IV-OCT images are first processed for the segmentation of the different structures. This also allows for automatic pullback calibration. Then, according to the segmentation results, different structures are depicted with different colors to visualize the vessel wall, the stent and the guide-wire in details. Final 3D rendering results are obtained through the use of a commercial 3D DICOM viewer. Manual analysis was used as ground-truth for the validation of the segmentation algorithms. A correlation value of 0.99 and good limits of agreement (Bland Altman statistics) were found over 250 images randomly extracted from 25 in vivo pullbacks. Moreover, 3D rendering was compared to angiography, pictures of deployed stents made available by the manufacturers and to conventional 2D imaging corroborating visualization results. Computational time for the visualization of an entire data sets resulted to be ~74 sec. The proposed method allows for the on-line use of 3D IV-OCT during percutaneous coronary interventions, potentially allowing treatments optimization. PMID:23243578

  10. MRI-guided robotics at the U of Houston: evolving methodologies for interventions and surgeries.

    PubMed

    Tsekos, Nikolaos V

    2009-01-01

    Currently, we witness the rapid evolution of minimally invasive surgeries (MIS) and image guided interventions (IGI) for offering improved patient management and cost effectiveness. It is well recognized that sustaining and expand this paradigm shift would require new computational methodology that integrates sensing with multimodal imaging, actively controlled robotic manipulators, the patient and the operator. Such approach would include (1) assessing in real-time tissue deformation secondary to the procedure and physiologic motion, (2) monitoring the tool(s) in 3D, and (3) on-the-fly update information about the pathophysiology of the targeted tissue. With those capabilities, real time image guidance may facilitate a paradigm shift and methodological leap from "keyhole" visualization (i.e. endoscopy or laparoscopy) to one that uses a volumetric and informational rich perception of the Area of Operation (AoO). This capability may eventually enable a wider range and level of complexity IGI and MIS.

  11. A non-disruptive technology for robust 3D tool tracking for ultrasound-guided interventions.

    PubMed

    Mung, Jay; Vignon, Francois; Jain, Ameet

    2011-01-01

    In the past decade ultrasound (US) has become the preferred modality for a number of interventional procedures, offering excellent soft tissue visualization. The main limitation however is limited visualization of surgical tools. A new method is proposed for robust 3D tracking and US image enhancement of surgical tools under US guidance. Small US sensors are mounted on existing surgical tools. As the imager emits acoustic energy, the electrical signal from the sensor is analyzed to reconstruct its 3D coordinates. These coordinates can then be used for 3D surgical navigation, similar to current day tracking systems. A system with real-time 3D tool tracking and image enhancement was implemented on a commercial ultrasound scanner and 3D probe. Extensive water tank experiments with a tracked 0.2mm sensor show robust performance in a wide range of imaging conditions and tool position/orientations. The 3D tracking accuracy was 0.36 +/- 0.16mm throughout the imaging volume of 55 degrees x 27 degrees x 150mm. Additionally, the tool was successfully tracked inside a beating heart phantom. This paper proposes an image enhancement and tool tracking technology with sub-mm accuracy for US-guided interventions. The technology is non-disruptive, both in terms of existing clinical workflow and commercial considerations, showing promise for large scale clinical impact.

  12. Narrow band imaging combined with water immersion technique in the diagnosis of celiac disease.

    PubMed

    Valitutti, Francesco; Oliva, Salvatore; Iorfida, Donatella; Aloi, Marina; Gatti, Silvia; Trovato, Chiara Maria; Montuori, Monica; Tiberti, Antonio; Cucchiara, Salvatore; Di Nardo, Giovanni

    2014-12-01

    The "multiple-biopsy" approach both in duodenum and bulb is the best strategy to confirm the diagnosis of celiac disease; however, this increases the invasiveness of the procedure itself and is time-consuming. To evaluate the diagnostic yield of a single biopsy guided by narrow-band imaging combined with water immersion technique in paediatric patients. Prospective assessment of the diagnostic accuracy of narrow-band imaging/water immersion technique-driven biopsy approach versus standard protocol in suspected celiac disease. The experimental approach correctly diagnosed 35/40 children with celiac disease, with an overall diagnostic sensitivity of 87.5% (95% CI: 77.3-97.7). An altered pattern of narrow-band imaging/water immersion technique endoscopic visualization was significantly associated with villous atrophy at guided biopsy (Spearman Rho 0.637, p<0.001). Concordance of narrow-band imaging/water immersion technique endoscopic assessments was high between two operators (K: 0.884). The experimental protocol was highly timesaving compared to the standard protocol. An altered narrow-band imaging/water immersion technique pattern coupled with high anti-transglutaminase antibodies could allow a single guided biopsy to diagnose celiac disease. When no altered mucosal pattern is visible even by narrow-band imaging/water immersion technique, multiple bulbar and duodenal biopsies should be obtained. Copyright © 2014. Published by Elsevier Ltd.

  13. Fusion imaging of contrast-enhanced ultrasound and contrast-enhanced CT or MRI before radiofrequency ablation for liver cancers.

    PubMed

    Bo, Xiao-Wan; Xu, Hui-Xiong; Wang, Dan; Guo, Le-Hang; Sun, Li-Ping; Li, Xiao-Long; Zhao, Chong-Ke; He, Ya-Ping; Liu, Bo-Ji; Li, Dan-Dan; Zhang, Kun

    2016-11-01

    To investigate the usefulness of fusion imaging of contrast-enhanced ultrasound (CEUS) and CECT/CEMRI before percutaneous ultrasound-guided radiofrequency ablation (RFA) for liver cancers. 45 consecutive patients with 70 liver lesions were included between March 2013 and October 2015, and all the lesions were identified on CEMRI/CECT prior to inclusion in the study. Planning ultrasound for percutaneous RFA was performed using conventional ultrasound, ultrasound-CECT/CEMRI and CEUS and CECT/CEMRI fusion imaging during the same session. The numbers of the conspicuous lesions on ultrasound and fusion imaging were recorded. RFA was performed according to the results of fusion imaging. Complete response (CR) rate was calculated and the complications were recorded. On conventional ultrasound, 25 (35.7%) of the 70 lesions were conspicuous, whereas 45 (64.3%) were inconspicuous. Ultrasound-CECT/CEMRI fusion imaging detected additional 24 lesions thus increased the number of the conspicuous lesions to 49 (70.0%) (70.0% vs 35.7%; p < 0.001 in comparison with conventional ultrasound). With the use of CEUS and CECT/CEMRI fusion imaging, the number of the conspicuous lesions further increased to 67 (95.7%, 67/70) (95.7% vs 70.0%, 95.7% vs 35.7%; both p < 0.001 in comparison with ultrasound and ultrasound-CECT/CEMRI fusion imaging, respectively). With the assistance of CEUS and CECT/CEMRI fusion imaging, the confidence level of the operator for performing RFA improved significantly with regard to visualization of the target lesions (p = 0.001). The CR rate for RFA was 97.0% (64/66) in accordance to the CECT/CEMRI results 1 month later. No procedure-related deaths and major complications occurred during and after RFA. Fusion of CEUS and CECT/CEMRI improves the visualization of those inconspicuous lesions on conventional ultrasound. It also facilitates improvement in the RFA operators' confidence and CR of RFA. Advances in knowledge: CEUS and CECT/CEMRI fusion imaging is better than both conventional ultrasound and ultrasound-CECT/CEMRI fusion imaging for lesion visualization and improves the operator confidence, thus it should be recommended to be used as a routine in ultrasound-guided percutaneous RFA procedures for liver cancer.

  14. Fusion imaging of contrast-enhanced ultrasound and contrast-enhanced CT or MRI before radiofrequency ablation for liver cancers

    PubMed Central

    Bo, Xiao-Wan; Wang, Dan; Guo, Le-Hang; Sun, Li-Ping; Li, Xiao-Long; Zhao, Chong-Ke; He, Ya-Ping; Liu, Bo-Ji; Li, Dan-Dan; Zhang, Kun

    2016-01-01

    Objective: To investigate the usefulness of fusion imaging of contrast-enhanced ultrasound (CEUS) and CECT/CEMRI before percutaneous ultrasound-guided radiofrequency ablation (RFA) for liver cancers. Methods: 45 consecutive patients with 70 liver lesions were included between March 2013 and October 2015, and all the lesions were identified on CEMRI/CECT prior to inclusion in the study. Planning ultrasound for percutaneous RFA was performed using conventional ultrasound, ultrasound-CECT/CEMRI and CEUS and CECT/CEMRI fusion imaging during the same session. The numbers of the conspicuous lesions on ultrasound and fusion imaging were recorded. RFA was performed according to the results of fusion imaging. Complete response (CR) rate was calculated and the complications were recorded. Results: On conventional ultrasound, 25 (35.7%) of the 70 lesions were conspicuous, whereas 45 (64.3%) were inconspicuous. Ultrasound-CECT/CEMRI fusion imaging detected additional 24 lesions thus increased the number of the conspicuous lesions to 49 (70.0%) (70.0% vs 35.7%; p < 0.001 in comparison with conventional ultrasound). With the use of CEUS and CECT/CEMRI fusion imaging, the number of the conspicuous lesions further increased to 67 (95.7%, 67/70) (95.7% vs 70.0%, 95.7% vs 35.7%; both p < 0.001 in comparison with ultrasound and ultrasound-CECT/CEMRI fusion imaging, respectively). With the assistance of CEUS and CECT/CEMRI fusion imaging, the confidence level of the operator for performing RFA improved significantly with regard to visualization of the target lesions (p = 0.001). The CR rate for RFA was 97.0% (64/66) in accordance to the CECT/CEMRI results 1 month later. No procedure-related deaths and major complications occurred during and after RFA. Conclusion: Fusion of CEUS and CECT/CEMRI improves the visualization of those inconspicuous lesions on conventional ultrasound. It also facilitates improvement in the RFA operators' confidence and CR of RFA. Advances in knowledge: CEUS and CECT/CEMRI fusion imaging is better than both conventional ultrasound and ultrasound-CECT/CEMRI fusion imaging for lesion visualization and improves the operator confidence, thus it should be recommended to be used as a routine in ultrasound-guided percutaneous RFA procedures for liver cancer. PMID:27626506

  15. How I Do It: Cone-Beam CT during Transarterial Chemoembolization for Liver Cancer

    PubMed Central

    Tacher, Vania; Radaelli, Alessandro; Lin, MingDe

    2015-01-01

    Cone-beam computed tomography (CBCT) is an imaging technique that provides computed tomographic (CT) images from a rotational scan acquired with a C-arm equipped with a flat panel detector. Utilizing CBCT images during interventional procedures bridges the gap between the world of diagnostic imaging (typically three-dimensional imaging but performed separately from the procedure) and that of interventional radiology (typically two-dimensional imaging). CBCT is capable of providing more information than standard two-dimensional angiography in localizing and/or visualizing liver tumors (“seeing” the tumor) and targeting tumors though precise microcatheter placement in close proximity to the tumors (“reaching” the tumor). It can also be useful in evaluating treatment success at the time of procedure (“assessing” treatment success). CBCT technology is rapidly evolving along with the development of various contrast material injection protocols and multiphasic CBCT techniques. The purpose of this article is to provide a review of the principles of CBCT imaging, including purpose and clinical evidence of the different techniques, and to introduce a decision-making algorithm as a guide for the routine utilization of CBCT during transarterial chemoembolization of liver cancer. © RSNA, 2015 Online supplemental material is available for this article. PMID:25625741

  16. Autonomous Diagnostic Imaging Performed by Untrained Operators using Augmented Reality as a Form of "Just-in-Time" Training

    NASA Technical Reports Server (NTRS)

    Martin, D. S.; Wang, L.; Laurie, S. S.; Lee, S. M. C.; Fleischer, A. C.; Gibson, C. R.; Stenger, M. B.

    2017-01-01

    We will address the Human Factors and Performance Team, "Risk of performance errors due to training deficiencies" by improving the JIT training materials for ultrasound and OCT imaging by providing advanced guidance in a detailed, timely, and user-friendly manner. Specifically, we will (1) develop an audio-visual tutorial using AR that guides non-experts through an abdominal trauma ultrasound protocol; (2) develop an audio-visual tutorial using AR to guide an untrained operator through the acquisition of OCT images; (3) evaluate the quality of abdominal ultrasound and OCT images acquired by untrained operators using AR guidance compared to images acquired using traditional JIT techniques (laptop-based training conducted before image acquisition); and (4) compare the time required to complete imaging studies using AR tutorials with images acquired using current JIT practices to identify areas for time efficiency improvements. Two groups of subjects will be recruited to participate in this study. Operator-subjects, without previous experience in ultrasound or OCT, will be asked to perform both procedures using either the JIT training with AR technology or the traditional JIT training via laptop. Images acquired by inexperienced operator-subjects will be scored by experts in that imaging modality for diagnostic and research quality; experts will be blinded to the form of JIT used to acquire the images. Operator-subjects also will be asked to submit feedback to improve the training modules used during the scans to improve future training modules. Scanned-subjects will be a small group individuals from whom all images will be acquired.

  17. Autonomous Diagnostic Imaging Performed by Untrained Operator Using Augmented Reality as a Form of "Just-in-Time" Training

    NASA Technical Reports Server (NTRS)

    Martin, David S.; Wang, Lui; Laurie, Steven S.; Lee, Stuart M. C.; Stenger, Michael B.

    2017-01-01

    We will address the Human Factors and Performance Team, "Risk of performance errors due to training deficiencies" by improving the JIT training materials for ultrasound and OCT imaging by providing advanced guidance in a detailed, timely, and user-friendly manner. Specifically, we will (1) develop an audio-visual tutorial using AR that guides non-experts through an abdominal trauma ultrasound protocol; (2) develop an audio-visual tutorial using AR to guide an untrained operator through the acquisition of OCT images; (3) evaluate the quality of abdominal ultrasound and OCT images acquired by untrained operators using AR guidance compared to images acquired using traditional JIT techniques (laptop-based training conducted before image acquisition); and (4) compare the time required to complete imaging studies using AR tutorials with images acquired using current JIT practices to identify areas for time efficiency improvements. Two groups of subjects will be recruited to participate in this study. Operator-subjects, without previous experience in ultrasound or OCT, will be asked to perform both procedures using either the JIT training with AR technology or the traditional JIT training via laptop. Images acquired by inexperienced operator-subjects will be scored by experts in that imaging modality for diagnostic and research quality; experts will be blinded to the form of JIT used to acquire the images. Operator-subjects also will be asked to submit feedback to improve the training modules used during the scans to improve future training modules. Scanned-subjects will be a small group individuals from whom all images will be acquired.

  18. Percutaneous magnetic resonance imaging-guided bone tumor management and magnetic resonance imaging-guided bone therapy.

    PubMed

    Sequeiros, Roberto Blanco; Fritz, Jan; Ojala, Risto; Carrino, John A

    2011-08-01

    Magnetic resonance imaging (MRI) is promising tool for image-guided therapy. In musculoskeletal setting, image-guided therapy is used to direct diagnostic and therapeutic procedures and to steer patient management. Studies have demonstrated that MRI-guided interventions involving bone, soft tissue, joints, and intervertebral disks are safe and in selected indications can be the preferred action to manage clinical situation. Often, these procedures are technically similar to those performed in other modalities (computed tomography, fluoroscopy) for bone and soft tissue lesions. However, the procedural perception to the operator can be very different to other modalities because of the vastly increased data.Magnetic resonance imaging guidance is particularly advantageous should the lesion not be visible by other modalities, for selective lesion targeting, intra-articular locations, cyst aspiration, and locations adjacent to surgical hardware. Palliative tumor-related pain management such as ablation therapy forms a subset of procedures that are frequently performed under MRI. Another suitable entity for MRI guidance are the therapeutic percutaneous osseous or joint-related benign or reactive conditions such as osteoid osteoma, epiphyseal bone bridging, osteochondritis dissecans, bone cysts, localized bone necrosis, and posttraumatic lesions. In this article, we will describe in detail the technical aspects of performing MRI-guided therapeutic musculoskeletal procedures as well as the clinical indications.

  19. Accuracy of neuro-navigated cranial screw placement using optical surface imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Jakubovic, Raphael; Gupta, Shuarya; Guha, Daipayan; Mainprize, Todd; Yang, Victor X. D.

    2017-02-01

    Cranial neurosurgical procedures are especially delicate considering that the surgeon must localize the subsurface anatomy with limited exposure and without the ability to see beyond the surface of the surgical field. Surgical accuracy is imperative as even minor surgical errors can cause major neurological deficits. Traditionally surgical precision was highly dependent on surgical skill. However, the introduction of intraoperative surgical navigation has shifted the paradigm to become the current standard of care for cranial neurosurgery. Intra-operative image guided navigation systems are currently used to allow the surgeon to visualize the three-dimensional subsurface anatomy using pre-acquired computed tomography (CT) or magnetic resonance (MR) images. The patient anatomy is fused to the pre-acquired images using various registration techniques and surgical tools are typically localized using optical tracking methods. Although these techniques positively impact complication rates, surgical accuracy is limited by the accuracy of the navigation system and as such quantification of surgical error is required. While many different measures of registration accuracy have been presented true navigation accuracy can only be quantified post-operatively by comparing a ground truth landmark to the intra-operative visualization. In this study we quantified the accuracy of cranial neurosurgical procedures using a novel optical surface imaging navigation system to visualize the three-dimensional anatomy of the surface anatomy. A tracked probe was placed on the screws of cranial fixation plates during surgery and the reported position of the centre of the screw was compared to the co-ordinates of the post-operative CT or MR images, thus quantifying cranial neurosurgical error.

  20. Computer-aided design and manufacturing of surgical templates and their clinical applications: a review.

    PubMed

    Chen, Xiaojun; Xu, Lu; Wang, Wei; Li, Xing; Sun, Yi; Politis, Constantinus

    2016-09-01

    The surgical template is a guide aimed at directing the implant placement, tumor resection, osteotomy and bone repositioning. Using it, preoperative planning can be transferred to the actual surgical site, and the precision, safety and reliability of the surgery can be improved. However, the actual workflow of the surgical template design and manufacturing is quite complicated before the final clinical application. The major goal of the paper is to provide a comprehensive reference source of the current and future development of the template design and manufacturing for relevant researchers. Expert commentary: This paper aims to present a review of the necessary procedures in the template-guided surgery including the image processing, 3D visualization, preoperative planning, surgical guide design and manufacturing. In addition, the template-guided clinical applications for various kinds of surgeries are reviewed, and it demonstrated that the precision of the surgery has been improved compared with the non-guided operations.

  1. Introduction of a standardized multimodality image protocol for navigation-guided surgery of suspected low-grade gliomas.

    PubMed

    Mert, Aygül; Kiesel, Barbara; Wöhrer, Adelheid; Martínez-Moreno, Mauricio; Minchev, Georgi; Furtner, Julia; Knosp, Engelbert; Wolfsberger, Stefan; Widhalm, Georg

    2015-01-01

    OBJECT Surgery of suspected low-grade gliomas (LGGs) poses a special challenge for neurosurgeons due to their diffusely infiltrative growth and histopathological heterogeneity. Consequently, neuronavigation with multimodality imaging data, such as structural and metabolic data, fiber tracking, and 3D brain visualization, has been proposed to optimize surgery. However, currently no standardized protocol has been established for multimodality imaging data in modern glioma surgery. The aim of this study was therefore to define a specific protocol for multimodality imaging and navigation for suspected LGG. METHODS Fifty-one patients who underwent surgery for a diffusely infiltrating glioma with nonsignificant contrast enhancement on MRI and available multimodality imaging data were included. In the first 40 patients with glioma, the authors retrospectively reviewed the imaging data, including structural MRI (contrast-enhanced T1-weighted, T2-weighted, and FLAIR sequences), metabolic images derived from PET, or MR spectroscopy chemical shift imaging, fiber tracking, and 3D brain surface/vessel visualization, to define standardized image settings and specific indications for each imaging modality. The feasibility and surgical relevance of this new protocol was subsequently prospectively investigated during surgery with the assistance of an advanced electromagnetic navigation system in the remaining 11 patients. Furthermore, specific surgical outcome parameters, including the extent of resection, histological analysis of the metabolic hotspot, presence of a new postoperative neurological deficit, and intraoperative accuracy of 3D brain visualization models, were assessed in each of these patients. RESULTS After reviewing these first 40 cases of glioma, the authors defined a specific protocol with standardized image settings and specific indications that allows for optimal and simultaneous visualization of structural and metabolic data, fiber tracking, and 3D brain visualization. This new protocol was feasible and was estimated to be surgically relevant during navigation-guided surgery in all 11 patients. According to the authors' predefined surgical outcome parameters, they observed a complete resection in all resectable gliomas (n = 5) by using contour visualization with T2-weighted or FLAIR images. Additionally, tumor tissue derived from the metabolic hotspot showed the presence of malignant tissue in all WHO Grade III or IV gliomas (n = 5). Moreover, no permanent postoperative neurological deficits occurred in any of these patients, and fiber tracking and/or intraoperative monitoring were applied during surgery in the vast majority of cases (n = 10). Furthermore, the authors found a significant intraoperative topographical correlation of 3D brain surface and vessel models with gyral anatomy and superficial vessels. Finally, real-time navigation with multimodality imaging data using the advanced electromagnetic navigation system was found to be useful for precise guidance to surgical targets, such as the tumor margin or the metabolic hotspot. CONCLUSIONS In this study, the authors defined a specific protocol for multimodality imaging data in suspected LGGs, and they propose the application of this new protocol for advanced navigation-guided procedures optimally in conjunction with continuous electromagnetic instrument tracking to optimize glioma surgery.

  2. Visually guided tube thoracostomy insertion comparison to standard of care in a large animal model.

    PubMed

    Hernandez, Matthew C; Vogelsang, David; Anderson, Jeff R; Thiels, Cornelius A; Beilman, Gregory; Zielinski, Martin D; Aho, Johnathon M

    2017-04-01

    Tube thoracostomy (TT) is a lifesaving procedure for a variety of thoracic pathologies. The most commonly utilized method for placement involves open dissection and blind insertion. Image guided placement is commonly utilized but is limited by an inability to see distal placement location. Unfortunately, TT is not without complications. We aim to demonstrate the feasibility of a disposable device to allow for visually directed TT placement compared to the standard of care in a large animal model. Three swine were sequentially orotracheally intubated and anesthetized. TT was conducted utilizing a novel visualization device, tube thoracostomy visual trocar (TTVT) and standard of care (open technique). Position of the TT in the chest cavity were recorded using direct thoracoscopic inspection and radiographic imaging with the operator blinded to results. Complications were evaluated using a validated complication grading system. Standard descriptive statistical analyses were performed. Thirty TT were placed, 15 using TTVT technique, 15 using standard of care open technique. All of the TT placed using TTVT were without complication and in optimal position. Conversely, 27% of TT placed using standard of care open technique resulted in complications. Necropsy revealed no injury to intrathoracic organs. Visual directed TT placement using TTVT is feasible and non-inferior to the standard of care in a large animal model. This improvement in instrumentation has the potential to greatly improve the safety of TT. Further study in humans is required. Therapeutic Level II. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Ultrasound imaging-guided intracardiac injection to develop a mouse model of breast cancer brain metastases followed by longitudinal MRI.

    PubMed

    Zhou, Heling; Zhao, Dawen

    2014-03-06

    Breast cancer brain metastasis, occurring in 30% of breast cancer patients at stage IV, is associated with high mortality. The median survival is only 6 months. It is critical to have suitable animal models to mimic the hemodynamic spread of the metastatic cells in the clinical scenario. Here, we are introducing the use of small animal ultrasound imaging to guide an accurate injection of brain tropical breast cancer cells into the left ventricle of athymic nude mice. Longitudinal MRI is used to assessing intracranial initiation and growth of brain metastases. Ultrasound-guided intracardiac injection ensures not only an accurate injection and hereby a higher successful rate but also significantly decreased mortality rate, as compared to our previous manual procedure. In vivo high resolution MRI allows the visualization of hyperintense multifocal lesions, as small as 310 µm in diameter on T2-weighted images at 3 weeks post injection. Follow-up MRI reveals intracranial tumor growth and increased number of metastases that distribute throughout the whole brain.

  4. Intraoperative MR-guided DBS implantation for treating PD and ET

    NASA Astrophysics Data System (ADS)

    Liu, Haiying; Maxwell, Robert E.; Truwit, Charles L.

    2001-05-01

    Deep brain stimulator (DBS) implantation is a promising treatment alternative for suppressing the motor tremor symptoms in Parkinson disease (PD) patient. The main objective is to develop a minimally invasive approach using high spatial resolution and soft-tissue contrast MR imaging techniques to guide the surgical placement of DBS. In the MR-guided procedure, the high spatial resolution MR images were obtained intra-operatively and used to target stereotactically a specific deep brain location. The neurosurgery for craniotomy was performed in the front of the magnet outside of the 10 Gauss line. Aided with positional registration assembly for the stereotactic head frame, the target location (VIM or GPi or STN) in deep brain areas was identified and measured from the MR images in reference to the markers in the calibration assembly of the head frame before the burrhole prep. In 20 patients, MR- guided DBS implantations have been performed according to the new methodology. MR-guided DBS implantation at high magnetic field strength has been shown to be feasible and desirable. In addition to the improved outcome, this offers a new surgical approach in which intra-operative visualization is possible during intervention, and any complications such as bleeding can be assessed in situ immediately prior to dural closure.

  5. Comparative Study With New Accuracy Metrics for Target Volume Contouring in PET Image Guided Radiation Therapy

    PubMed Central

    Shepherd, T; Teras, M; Beichel, RR; Boellaard, R; Bruynooghe, M; Dicken, V; Gooding, MJ; Julyan, PJ; Lee, JA; Lefèvre, S; Mix, M; Naranjo, V; Wu, X; Zaidi, H; Zeng, Z; Minn, H

    2017-01-01

    The impact of positron emission tomography (PET) on radiation therapy is held back by poor methods of defining functional volumes of interest. Many new software tools are being proposed for contouring target volumes but the different approaches are not adequately compared and their accuracy is poorly evaluated due to the ill-definition of ground truth. This paper compares the largest cohort to date of established, emerging and proposed PET contouring methods, in terms of accuracy and variability. We emphasize spatial accuracy and present a new metric that addresses the lack of unique ground truth. Thirty methods are used at 13 different institutions to contour functional volumes of interest in clinical PET/CT and a custom-built PET phantom representing typical problems in image guided radiotherapy. Contouring methods are grouped according to algorithmic type, level of interactivity and how they exploit structural information in hybrid images. Experiments reveal benefits of high levels of user interaction, as well as simultaneous visualization of CT images and PET gradients to guide interactive procedures. Method-wise evaluation identifies the danger of over-automation and the value of prior knowledge built into an algorithm. PMID:22692898

  6. Transperineal implantation of gold fiducial markers (gold seeds) for prostate image-guided radiation therapy: a feasible technique associated with a low risk of complications.

    PubMed

    Saad, Akram; Goldstein, Jeffrey; Lawrence, Yaacov Richard; Weiss, Ilana; Saad, Rasha; Spieler, Benjamin; Symon, Zvi

    2015-12-01

    The purpose is to describe the method, safety and efficacy of transperineal gold seed placement for image-guided radiation therapy. An ethics committee approved database was used to review records of consecutive patients from October 2008 through December 2013, who underwent transperineal implantation of three gold markers into the prostate using staged local anaesthesia and transrectal ultrasound. Seeds were counted on radiographs from CT simulation, first treatment and last treatment. Retention and use of at least three markers for kV/kV matching was considered a successful implant. A visual analogue scale (VAS) pain assessment was performed. SAS was used for data analysis. Fiducial marker placement was successful for kV/kV matching in 556/581 patients (95.7%). The procedure was aborted due to pain in two patients. Additional sedation during the procedure was required in two patients. Complications include urinary infections (2 patients, <0.5%) and transient haematuria (2 patients, <0.5%). There were no recorded calls requesting additional pain medication or delays in radiation due to complications. The number of seeds identified at simulation: 4 (2 patients), 3 (554 patients), 2 (21 patients), 1 (1 patient), 0 (1 patient). One patient with three seeds and two patients with <2 seeds had cone beam CT instead of kV/kV imaging for image guidance. No seeds were lost after simulation. The mean visual analogue pain score associated with transperineal gold seed insertion met patients' expectations (respectively 4.1 vs. 4.4 P = 0.19). Outpatient transperineal insertion of fiducials avoids the rectum, is effective, convenient, well tolerated and has few side effects.

  7. Thirty-day emergency room visits and hospital admissions after outpatient non-vascular image-guided procedures.

    PubMed

    Nguyen, Quang; Mehta, Sahil V; Fang, Jieming; Sheiman, Robert; Kane, Robert; Ahmed, Muneeb; Sarwar, Ammar; Siewert, Bettina; Brook, Olga R

    2017-10-01

    To evaluate the rate of post-procedure emergency department (ED) visits and hospital admissions following outpatient non-vascular image-guided interventions performed under moderate sedation and to identify common and preventable causes of emergency department visits and hospital admissions. Institutional review board approval was acquired for this HIPAA-compliant retrospective study with waiver of informed consent. 1426 consecutive patients undergoing 1512 outpatient image-guided procedures under moderate sedation from November 2012 to August 2014 were included. The average patient age was 57.2 ± 15.2 years, and 602 (42%) patients were women. Major procedure categories included ultrasound-guided liver biopsies, ultrasound-guided kidney biopsies, and CT-guided lung biopsies/fiducial placement. Procedure details and medical follow-up within and after 30 days of the procedure were analyzed. A total of 168 (11.8%) patients were admitted to the hospital within 30 days of the procedure, with 29 of the admissions (17.3% of total admissions and 1.9% of total procedures) being procedure related. The most common procedure-related complication that required admission was hemorrhage (10/29, 34.5% of procedure-related admissions, 6.0% of total admissions, and 0.7% of total procedures), followed by pneumothorax (9/29, 31%, 5.4%, 0.6%), infection (4/29, 13.8%, 2.4%, 0.3%), and pain (3/29, 10.3%, 1.8%, 0.2%). Eighteen (62.1%) procedure-related admissions were immediately indicated. Thirty patients visited the ED and were subsequently discharged without admission with eight of the visits being procedure related (8/1512, 0.5%). All the procedure-related ED visits were due to pain. There were two deaths (2/1512, 0.1%) related to procedures, one from a thromboembolic event and another from post-biopsy hemorrhage. Outpatient non-vascular image-guided procedures result in a 30-day 1.9% hospital admission, 30-day 0.5% emergency room visit, and 30-day 0.1% mortality rate.

  8. Workflow oriented software support for image guided radiofrequency ablation of focal liver malignancies

    NASA Astrophysics Data System (ADS)

    Weihusen, Andreas; Ritter, Felix; Kröger, Tim; Preusser, Tobias; Zidowitz, Stephan; Peitgen, Heinz-Otto

    2007-03-01

    Image guided radiofrequency (RF) ablation has taken a significant part in the clinical routine as a minimally invasive method for the treatment of focal liver malignancies. Medical imaging is used in all parts of the clinical workflow of an RF ablation, incorporating treatment planning, interventional targeting and result assessment. This paper describes a software application, which has been designed to support the RF ablation workflow under consideration of the requirements of clinical routine, such as easy user interaction and a high degree of robust and fast automatic procedures, in order to keep the physician from spending too much time at the computer. The application therefore provides a collection of specialized image processing and visualization methods for treatment planning and result assessment. The algorithms are adapted to CT as well as to MR imaging. The planning support contains semi-automatic methods for the segmentation of liver tumors and the surrounding vascular system as well as an interactive virtual positioning of RF applicators and a concluding numerical estimation of the achievable heat distribution. The assessment of the ablation result is supported by the segmentation of the coagulative necrosis and an interactive registration of pre- and post-interventional image data for the comparison of tumor and necrosis segmentation masks. An automatic quantification of surface distances is performed to verify the embedding of the tumor area into the thermal lesion area. The visualization methods support representations in the commonly used orthogonal 2D view as well as in 3D scenes.

  9. Interventional multispectral photoacoustic imaging with a clinical linear array ultrasound probe for guiding nerve blocks

    NASA Astrophysics Data System (ADS)

    Xia, Wenfeng; West, Simeon J.; Nikitichev, Daniil I.; Ourselin, Sebastien; Beard, Paul C.; Desjardins, Adrien E.

    2016-03-01

    Accurate identification of tissue structures such as nerves and blood vessels is critically important for interventional procedures such as nerve blocks. Ultrasound imaging is widely used as a guidance modality to visualize anatomical structures in real-time. However, identification of nerves and small blood vessels can be very challenging, and accidental intra-neural or intra-vascular injections can result in significant complications. Multi-spectral photoacoustic imaging can provide high sensitivity and specificity for discriminating hemoglobin- and lipid-rich tissues. However, conventional surface-illumination-based photoacoustic systems suffer from limited sensitivity at large depths. In this study, for the first time, an interventional multispectral photoacoustic imaging (IMPA) system was used to image nerves in a swine model in vivo. Pulsed excitation light with wavelengths in the ranges of 750 - 900 nm and 1150 - 1300 nm was delivered inside the body through an optical fiber positioned within the cannula of an injection needle. Ultrasound waves were received at the tissue surface using a clinical linear array imaging probe. Co-registered B-mode ultrasound images were acquired using the same imaging probe. Nerve identification was performed using a combination of B-mode ultrasound imaging and electrical stimulation. Using a linear model, spectral-unmixing of the photoacoustic data was performed to provide image contrast for oxygenated and de-oxygenated hemoglobin, water and lipids. Good correspondence between a known nerve location and a lipid-rich region in the photoacoustic images was observed. The results indicate that IMPA is a promising modality for guiding nerve blocks and other interventional procedures. Challenges involved with clinical translation are discussed.

  10. Capturing intraoperative deformations: research experience at Brigham and Women's Hospital.

    PubMed

    Warfield, Simon K; Haker, Steven J; Talos, Ion-Florin; Kemper, Corey A; Weisenfeld, Neil; Mewes, Andrea U J; Goldberg-Zimring, Daniel; Zou, Kelly H; Westin, Carl-Fredrik; Wells, William M; Tempany, Clare M C; Golby, Alexandra; Black, Peter M; Jolesz, Ferenc A; Kikinis, Ron

    2005-04-01

    During neurosurgical procedures the objective of the neurosurgeon is to achieve the resection of as much diseased tissue as possible while achieving the preservation of healthy brain tissue. The restricted capacity of the conventional operating room to enable the surgeon to visualize critical healthy brain structures and tumor margin has lead, over the past decade, to the development of sophisticated intraoperative imaging techniques to enhance visualization. However, both rigid motion due to patient placement and nonrigid deformations occurring as a consequence of the surgical intervention disrupt the correspondence between preoperative data used to plan surgery and the intraoperative configuration of the patient's brain. Similar challenges are faced in other interventional therapies, such as in cryoablation of the liver, or biopsy of the prostate. We have developed algorithms to model the motion of key anatomical structures and system implementations that enable us to estimate the deformation of the critical anatomy from sequences of volumetric images and to prepare updated fused visualizations of preoperative and intraoperative images at a rate compatible with surgical decision making. This paper reviews the experience at Brigham and Women's Hospital through the process of developing and applying novel algorithms for capturing intraoperative deformations in support of image guided therapy.

  11. Feasibility of Retrograde Ureteral Contrast Injection to Guide Ultrasonographic Percutaneous Renal Access in the Nondilated Collecting System.

    PubMed

    Usawachintachit, Manint; Tzou, David T; Mongan, John; Taguchi, Kazumi; Weinstein, Stefanie; Chi, Thomas

    2017-02-01

    Ultrasound-guided percutaneous nephrolithotomy (PCNL) has become increasingly utilized. Patients with nondilated collecting systems represent a challenge: the target calix is often difficult to visualize. Here we report pilot study results for retrograde ultrasound contrast injection to aid in percutaneous renal access during ultrasound-guided PCNL. From April to July 2016, consecutive patients over the age of 18 years with nondilated collecting systems on preoperative imaging who presented for PCNL were enrolled. B-mode ultrasound imaging was compared with contrast-enhanced mode with simultaneous retrograde injection of Optison™ via an ipsilateral ureteral catheter. Five patients (four males and one female) with renal stones underwent PCNL with retrograde ultrasound contrast injection during the study period. Mean body mass index was 28.3 ± 5.6 kg/m 2 and mean stone size was 24.5 ± 12.0 mm. Under B-mode ultrasound, all patients demonstrated nondilated renal collecting systems that appeared as hyperechoic areas, where it was difficult to identify a target calix for puncture. Retrograde contrast injection facilitated delineation of all renal calices initially difficult to visualize under B-mode ultrasound. Renal puncture was then performed effectively in all cases with a mean puncture time of 55.4 ± 44.8 seconds. All PCNL procedures were completed without intraoperative complications and no adverse events related to ultrasound contrast injection occurred. Retrograde ultrasound contrast injection as an aide for renal puncture during PCNL is a feasible technique. By improving visualization of the collecting system, it facilitates needle placement in challenging patients without hydronephrosis. Future larger scale studies comparing its use to standard ultrasound-guided technique will be required to validate this concept.

  12. Use of Intracardiac Echocardiography in Interventional Cardiology: Working With the Anatomy Rather Than Fighting It.

    PubMed

    Enriquez, Andres; Saenz, Luis C; Rosso, Raphael; Silvestry, Frank E; Callans, David; Marchlinski, Francis E; Garcia, Fermin

    2018-05-22

    The indications for catheter-based structural and electrophysiological procedures have recently expanded to more complex scenarios, in which an accurate definition of the variable individual cardiac anatomy is key to obtain optimal results. Intracardiac echocardiography (ICE) is a unique imaging modality able to provide high-resolution real-time visualization of cardiac structures, continuous monitoring of catheter location within the heart, and early recognition of procedural complications, such as pericardial effusion or thrombus formation. Additional benefits are excellent patient tolerance, reduction of fluoroscopy time, and lack of need for general anesthesia or a second operator. For these reasons, ICE has largely replaced transesophageal echocardiography as ideal imaging modality for guiding certain procedures, such as atrial septal defect closure and catheter ablation of cardiac arrhythmias, and has an emerging role in others, including mitral valvuloplasty, transcatheter aortic valve replacement, and left atrial appendage closure. In electrophysiology procedures, ICE allows integration of real-time images with electroanatomic maps; it has a role in assessment of arrhythmogenic substrate, and it is particularly useful for mapping structures that are not visualized by fluoroscopy, such as the interatrial or interventricular septum, papillary muscles, and intracavitary muscular ridges. Most recently, a three-dimensional (3D) volumetric ICE system has also been developed, with potential for greater anatomic information and a promising role in structural interventions. In this state-of-the-art review, we provide guidance on how to conduct a comprehensive ICE survey and summarize the main applications of ICE in a variety of structural and electrophysiology procedures. © 2018 American Heart Association, Inc.

  13. Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography.

    PubMed

    Brun, E; Grandl, S; Sztrókay-Gaul, A; Barbone, G; Mittone, A; Gasilov, S; Bravin, A; Coan, P

    2014-11-01

    Phase contrast computed tomography has emerged as an imaging method, which is able to outperform present day clinical mammography in breast tumor visualization while maintaining an equivalent average dose. To this day, no segmentation technique takes into account the specificity of the phase contrast signal. In this study, the authors propose a new mathematical framework for human-guided breast tumor segmentation. This method has been applied to high-resolution images of excised human organs, each of several gigabytes. The authors present a segmentation procedure based on the viscous watershed transform and demonstrate the efficacy of this method on analyzer based phase contrast images. The segmentation of tumors inside two full human breasts is then shown as an example of this procedure's possible applications. A correct and precise identification of the tumor boundaries was obtained and confirmed by manual contouring performed independently by four experienced radiologists. The authors demonstrate that applying the watershed viscous transform allows them to perform the segmentation of tumors in high-resolution x-ray analyzer based phase contrast breast computed tomography images. Combining the additional information provided by the segmentation procedure with the already high definition of morphological details and tissue boundaries offered by phase contrast imaging techniques, will represent a valuable multistep procedure to be used in future medical diagnostic applications.

  14. Accuracy Considerations in Image-guided Cardiac Interventions: Experience and Lessons Learned

    PubMed Central

    Linte, Cristian A.; Lang, Pencilla; Rettmann, Maryam E.; Cho, Daniel S.; Holmes, David R.; Robb, Richard A.; Peters, Terry M.

    2014-01-01

    Motivation Medical imaging and its application in interventional guidance has revolutionized the development of minimally invasive surgical procedures leading to reduced patient trauma, fewer risks, and shorter recovery times. However, a frequently posed question with regards to an image guidance system is “how accurate is it?” On one hand, the accuracy challenge can be posed in terms of the tolerable clinical error associated with the procedure; on the other hand, accuracy is bound by the limitations of the system’s components, including modeling, patient registration, and surgical instrument tracking, all of which ultimately impact the overall targeting capabilities of the system. Methods While these processes are not unique to any interventional specialty, this paper discusses them in the context of two different cardiac image-guidance platforms: a model-enhanced ultrasound platform for intracardiac interventions and a prototype system for advanced visualization in image-guided cardiac ablation therapy. Results Pre-operative modeling techniques involving manual, semi-automatic and registration-based segmentation are discussed. The performance and limitations of clinically feasible approaches for patient registration evaluated both in the laboratory and operating room are presented. Our experience with two different magnetic tracking systems for instrument and ultrasound transducer localization is reported. Ultimately, the overall accuracy of the systems is discussed based on both in vitro and preliminary in vivo experience. Conclusion While clinical accuracy is specific to a particular patient and procedure and vastly dependent on the surgeon’s experience, the system’s engineering limitations are critical to determine whether the clinical requirements can be met. PMID:21671097

  15. Multiscale infrared and visible image fusion using gradient domain guided image filtering

    NASA Astrophysics Data System (ADS)

    Zhu, Jin; Jin, Weiqi; Li, Li; Han, Zhenghao; Wang, Xia

    2018-03-01

    For better surveillance with infrared and visible imaging, a novel hybrid multiscale decomposition fusion method using gradient domain guided image filtering (HMSD-GDGF) is proposed in this study. In this method, hybrid multiscale decomposition with guided image filtering and gradient domain guided image filtering of source images are first applied before the weight maps of each scale are obtained using a saliency detection technology and filtering means with three different fusion rules at different scales. The three types of fusion rules are for small-scale detail level, large-scale detail level, and base level. Finally, the target becomes more salient and can be more easily detected in the fusion result, with the detail information of the scene being fully displayed. After analyzing the experimental comparisons with state-of-the-art fusion methods, the HMSD-GDGF method has obvious advantages in fidelity of salient information (including structural similarity, brightness, and contrast), preservation of edge features, and human visual perception. Therefore, visual effects can be improved by using the proposed HMSD-GDGF method.

  16. Topography-guided transepithelial PRK after intracorneal ring segments implantation and corneal collagen CXL in a three-step procedure for keratoconus.

    PubMed

    Coskunseven, Efekan; Jankov, Mirko R; Grentzelos, Michael A; Plaka, Argyro D; Limnopoulou, Aliki N; Kymionis, George D

    2013-01-01

    To present the results of topography-guided transepithelial photorefractive keratectomy (PRK) after intracorneal ring segments implantation followed by corneal collagen cross-linking (CXL) for keratoconus. In this prospective case series, 10 patients (16 eyes) with progressive keratoconus were included. All patients underwent topography-guided transepithelial PRK after Keraring intracorneal ring segments (Mediphacos Ltda) implantation, followed by CXL treatment. The follow-up period was 6 months after the last procedure for all patients. Time interval between both intracorneal ring segments implantation and CXL and between CXL and topography-guided transepithelial PRK was 6 months. LogMAR mean uncorrected distance visual acuity and mean corrected distance visual acuity were significantly improved (P<.05) from 1.14±0.36 and 0.75±0.24 preoperatively to 0.25±0.13 and 0.13±0.06 after the completion of the three-step procedure, respectively. Mean spherical equivalent refraction was significantly reduced (P<.05) from -5.66±5.63 diopters (D) preoperatively to -0.98±2.21 D after the three-step procedure. Mean steep and flat keratometry values were significantly reduced (P<.05) from 54.65±5.80 D and 47.80±3.97 D preoperatively to 45.99±3.12 D and 44.69±3.19 D after the three-step procedure, respectively. Combined topography-guided transepithelial PRK with intracorneal ring segments implantation and CXL in a three-step procedure seems to be an effective, promising treatment sequence offering patients a functional visual acuity and ceasing progression of the ectatic disorder. A longer follow-up and larger case series are necessary to thoroughly evaluate safety, stability, and efficacy of this innovative procedure. Copyright 2013, SLACK Incorporated.

  17. Image-guided surgery and therapy: current status and future directions

    NASA Astrophysics Data System (ADS)

    Peters, Terence M.

    2001-05-01

    Image-guided surgery and therapy is assuming an increasingly important role, particularly considering the current emphasis on minimally-invasive surgical procedures. Volumetric CT and MR images have been used now for some time in conjunction with stereotactic frames, to guide many neurosurgical procedures. With the development of systems that permit surgical instruments to be tracked in space, image-guided surgery now includes the use of frame-less procedures, and the application of the technology has spread beyond neurosurgery to include orthopedic applications and therapy of various soft-tissue organs such as the breast, prostate and heart. Since tracking systems allow image- guided surgery to be undertaken without frames, a great deal of effort has been spent on image-to-image and image-to- patient registration techniques, and upon the means of combining real-time intra-operative images with images acquired pre-operatively. As image-guided surgery systems have become increasingly sophisticated, the greatest challenges to their successful adoption in the operating room of the future relate to the interface between the user and the system. To date, little effort has been expended to ensure that the human factors issues relating to the use of such equipment in the operating room have been adequately addressed. Such systems will only be employed routinely in the OR when they are designed to be intuitive, unobtrusive, and provide simple access to the source of the images.

  18. The GOSTT concept and hybrid mixed/virtual/augmented reality environment radioguided surgery.

    PubMed

    Valdés Olmos, R A; Vidal-Sicart, S; Giammarile, F; Zaknun, J J; Van Leeuwen, F W; Mariani, G

    2014-06-01

    The popularity gained by the sentinel lymph node (SLN) procedure in the last two decades did increase the interest of the surgical disciplines for other applications of radioguided surgery. An example is the gamma-probe guided localization of occult or difficult to locate neoplastic lesions. Such guidance can be achieved by intralesional delivery (ultrasound, stereotaxis or CT) of a radiolabelled agent that remains accumulated at the site of the injection. Another possibility rested on the use of systemic administration of a tumour-seeking radiopharmaceutical with favourable tumour accumulation and retention. On the other hand, new intraoperative imaging devices for radioguided surgery in complex anatomical areas became available. All this a few years ago led to the delineation of the concept Guided intraOperative Scintigraphic Tumour Targeting (GOSTT) to include the whole spectrum of basic and advanced nuclear medicine procedures required for providing a roadmap that would optimise surgery. The introduction of allied signatures using, e.g. hybrid tracers for simultaneous detection of the radioactive and fluorescent signals did amply the GOSTT concept. It was now possible to combine perioperative nuclear medicine imaging with the superior resolution of additional optical guidance in the operating room. This hybrid approach is currently in progress and probably will become an important model to follow in the coming years. A cornerstone in the GOSTT concept is constituted by diagnostic imaging technologies like SPECT/CT. SPECT/CT was introduced halfway the past decade and was immediately incorporated into the SLN procedure. Important reasons attributing to the success of SPECT/CT were its combination with lymphoscintigraphy, and the ability to display SLNs in an anatomical environment. This latter aspect has significantly been improved in the new generation of SPECT/CT cameras and provides the base for the novel mixed reality protocols of image-guided surgery. In these protocols the generated virtual SPECT/CT elements are visually superimposed in the body of the patient in the operating room to directly facilitate, by means of visualization on screen or using head-mounted devices, the localization of radioactive and/or fluorescent targets by minimal invasive approaches in areas of complex anatomy. All these technological advances will play an increasing role in the future extension and the clinical impact of the GOSTT concept.

  19. Linear perspective limitations on virtual reality and realistic displays

    NASA Astrophysics Data System (ADS)

    Temme, Leonard A.

    2007-04-01

    The visual images of the natural world, with their immediate intuitive appeal, seem like the logical gold standard for evaluating displays. After all, since photorealistic displays look so increasingly like the real world, what could be better? Part of the shortcoming of this intuitive appeal for displays is its naivete. Realism itself is full of potential illusions that we do not notice because, most of the time, realism is good enough for our everyday tasks. But when confronted with tasks that go beyond those for which our visual system has evolved, we may be blindsided. If we survive, blind to our erroneous perceptions and oblivious to our good fortune at having survived, we will not be any wiser next time. Realist displays depend on linear perspective (LP), the mathematical mapping of three dimensions onto two. Despite the fact that LP is a seductively elegant system that predicts results with defined mathematical procedures, artists do not stick to the procedures, not because they are math-phobic but because LP procedures, if followed explicitly, produce ugly, limited, and distorted images. If artists bother with formal LP procedures at all, they invariably temper the renderings by eye. The present paper discusses LP assumptions, limitations, and distortions. It provides examples of kluges to cover some of these LP shortcomings. It is important to consider the limitations of LP so that we do not let either naive assumptions or the seductive power of LP guide our thinking or expectations unrealistically as we consider its possible uses in advanced visual displays.

  20. A novel graphical user interface for ultrasound-guided shoulder arthroscopic surgery

    NASA Astrophysics Data System (ADS)

    Tyryshkin, K.; Mousavi, P.; Beek, M.; Pichora, D.; Abolmaesumi, P.

    2007-03-01

    This paper presents a novel graphical user interface developed for a navigation system for ultrasound-guided computer-assisted shoulder arthroscopic surgery. The envisioned purpose of the interface is to assist the surgeon in determining the position and orientation of the arthroscopic camera and other surgical tools within the anatomy of the patient. The user interface features real time position tracking of the arthroscopic instruments with an optical tracking system, and visualization of their graphical representations relative to a three-dimensional shoulder surface model of the patient, created from computed tomography images. In addition, the developed graphical interface facilitates fast and user-friendly intra-operative calibration of the arthroscope and the arthroscopic burr, capture and segmentation of ultrasound images, and intra-operative registration. A pilot study simulating the computer-aided shoulder arthroscopic procedure on a shoulder phantom demonstrated the speed, efficiency and ease-of-use of the system.

  1. Image-guided interventional procedures in the dog and cat.

    PubMed

    Vignoli, Massimo; Saunders, Jimmy H

    2011-03-01

    Medical imaging is essential for the diagnostic workup of many soft tissue and bone lesions in dogs and cats, but imaging modalities do not always allow the clinician to differentiate inflammatory or infectious conditions from neoplastic disorders. This review describes interventional procedures in dogs and cats for collection of samples for cytological or histopathological examinations under imaging guidance. It describes the indications and procedures for imaging-guided sampling, including ultrasound (US), computed tomography (CT), magnetic resonance imaging and fluoroscopy. US and CT are currently the modalities of choice in interventional imaging. Copyright © 2009 Elsevier Ltd. All rights reserved.

  2. Intraoperative visualization and assessment of electromagnetic tracking error

    NASA Astrophysics Data System (ADS)

    Harish, Vinyas; Ungi, Tamas; Lasso, Andras; MacDonald, Andrew; Nanji, Sulaiman; Fichtinger, Gabor

    2015-03-01

    Electromagnetic tracking allows for increased flexibility in designing image-guided interventions, however it is well understood that electromagnetic tracking is prone to error. Visualization and assessment of the tracking error should take place in the operating room with minimal interference with the clinical procedure. The goal was to achieve this ideal in an open-source software implementation in a plug and play manner, without requiring programming from the user. We use optical tracking as a ground truth. An electromagnetic sensor and optical markers are mounted onto a stylus device, pivot calibrated for both trackers. Electromagnetic tracking error is defined as difference of tool tip position between electromagnetic and optical readings. Multiple measurements are interpolated into the thin-plate B-spline transform visualized in real time using 3D Slicer. All tracked devices are used in a plug and play manner through the open-source SlicerIGT and PLUS extensions of the 3D Slicer platform. Tracking error was measured multiple times to assess reproducibility of the method, both with and without placing ferromagnetic objects in the workspace. Results from exhaustive grid sampling and freehand sampling were similar, indicating that a quick freehand sampling is sufficient to detect unexpected or excessive field distortion in the operating room. The software is available as a plug-in for the 3D Slicer platforms. Results demonstrate potential for visualizing electromagnetic tracking error in real time for intraoperative environments in feasibility clinical trials in image-guided interventions.

  3. Image fusion and navigation platforms for percutaneous image-guided interventions.

    PubMed

    Rajagopal, Manoj; Venkatesan, Aradhana M

    2016-04-01

    Image-guided interventional procedures, particularly image guided biopsy and ablation, serve an important role in the care of the oncology patient. The need for tumor genomic and proteomic profiling, early tumor response assessment and confirmation of early recurrence are common scenarios that may necessitate successful biopsies of targets, including those that are small, anatomically unfavorable or inconspicuous. As image-guided ablation is increasingly incorporated into interventional oncology practice, similar obstacles are posed for the ablation of technically challenging tumor targets. Navigation tools, including image fusion and device tracking, can enable abdominal interventionalists to more accurately target challenging biopsy and ablation targets. Image fusion technologies enable multimodality fusion and real-time co-displays of US, CT, MRI, and PET/CT data, with navigational technologies including electromagnetic tracking, robotic, cone beam CT, optical, and laser guidance of interventional devices. Image fusion and navigational platform technology is reviewed in this article, including the results of studies implementing their use for interventional procedures. Pre-clinical and clinical experiences to date suggest these technologies have the potential to reduce procedure risk, time, and radiation dose to both the patient and the operator, with a valuable role to play for complex image-guided interventions.

  4. Rapid fusion of 2D X-ray fluoroscopy with 3D multislice CT for image-guided electrophysiology procedures

    NASA Astrophysics Data System (ADS)

    Zagorchev, Lyubomir; Manzke, Robert; Cury, Ricardo; Reddy, Vivek Y.; Chan, Raymond C.

    2007-03-01

    Interventional cardiac electrophysiology (EP) procedures are typically performed under X-ray fluoroscopy for visualizing catheters and EP devices relative to other highly-attenuating structures such as the thoracic spine and ribs. These projections do not however contain information about soft-tissue anatomy and there is a recognized need for fusion of conventional fluoroscopy with pre-operatively acquired cardiac multislice computed tomography (MSCT) volumes. Rapid 2D-3D integration in this application would allow for real-time visualization of all catheters present within the thorax in relation to the cardiovascular anatomy visible in MSCT. We present a method for rapid fusion of 2D X-ray fluoroscopy with 3DMSCT that can facilitate EP mapping and interventional procedures by reducing the need for intra-operative contrast injections to visualize heart chambers and specialized systems to track catheters within the cardiovascular anatomy. We use hardware-accelerated ray-casting to compute digitally reconstructed radiographs (DRRs) from the MSCT volume and iteratively optimize the rigid-body pose of the volumetric data to maximize the similarity between the MSCT-derived DRR and the intra-operative X-ray projection data.

  5. Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking.

    PubMed

    Titiyal, Jeewan S; Kaur, Manpreet; Jose, Cijin P; Falera, Ruchita; Kinkar, Ashutosh; Bageshwar, Lalit Ms

    2018-01-01

    To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality. This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30. Deviation from the target axis of implantation was significantly less in group II on PODs 1 and 30 (group I: 5.5°±3.3°, group II: 3.6°±2.6°; p =0.005). Postoperative refractive cylinder was -0.89±0.35 D in group I and -0.64±0.36 D in group II ( p =0.003). Visual acuity was comparable between both the groups. Visual quality measured in terms of Strehl ratio ( p <0.05) and modulation transfer function (MTF) ( p <0.05) was significantly better in the image-guided surgery group. Significant negative correlation was observed between deviation from target axis and visual quality parameters (Strehl ratio and MTF) ( p <0.05). Image-guided surgery allows precise alignment of toric IOL without need for reference marking. It is associated with superior visual quality which correlates with the precision of IOL alignment.

  6. Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking

    PubMed Central

    Titiyal, Jeewan S; Kaur, Manpreet; Jose, Cijin P; Falera, Ruchita; Kinkar, Ashutosh; Bageshwar, Lalit MS

    2018-01-01

    Purpose To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality. Patients and methods This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30. Results Deviation from the target axis of implantation was significantly less in group II on PODs 1 and 30 (group I: 5.5°±3.3°, group II: 3.6°±2.6°; p=0.005). Postoperative refractive cylinder was −0.89±0.35 D in group I and −0.64±0.36 D in group II (p=0.003). Visual acuity was comparable between both the groups. Visual quality measured in terms of Strehl ratio (p<0.05) and modulation transfer function (MTF) (p<0.05) was significantly better in the image-guided surgery group. Significant negative correlation was observed between deviation from target axis and visual quality parameters (Strehl ratio and MTF) (p<0.05). Conclusion Image-guided surgery allows precise alignment of toric IOL without need for reference marking. It is associated with superior visual quality which correlates with the precision of IOL alignment. PMID:29731603

  7. MRI-powered biomedical devices.

    PubMed

    Hovet, Sierra; Ren, Hongliang; Xu, Sheng; Wood, Bradford; Tokuda, Junichi; Tse, Zion Tsz Ho

    2017-11-16

    Magnetic resonance imaging (MRI) is beneficial for imaging-guided procedures because it provides higher resolution images and better soft tissue contrast than computed tomography (CT), ultrasound, and X-ray. MRI can be used to streamline diagnostics and treatment because it does not require patients to be repositioned between scans of different areas of the body. It is even possible to use MRI to visualize, power, and control medical devices inside the human body to access remote locations and perform minimally invasive procedures. Therefore, MR conditional medical devices have the potential to improve a wide variety of medical procedures; this potential is explored in terms of practical considerations pertaining to clinical applications and the MRI environment. Recent advancements in this field are introduced with a review of clinically relevant research in the areas of interventional tools, endovascular microbots, and closed-loop controlled MRI robots. Challenges related to technology and clinical feasibility are discussed, including MRI based propulsion and control, navigation of medical devices through the human body, clinical adoptability, and regulatory issues. The development of MRI-powered medical devices is an emerging field, but the potential clinical impact of these devices is promising.

  8. Using Highlighting to Train Attentional Expertise

    PubMed Central

    Roads, Brett; Mozer, Michael C.; Busey, Thomas A.

    2016-01-01

    Acquiring expertise in complex visual tasks is time consuming. To facilitate the efficient training of novices on where to look in these tasks, we propose an attentional highlighting paradigm. Highlighting involves dynamically modulating the saliency of a visual image to guide attention along the fixation path of a domain expert who had previously viewed the same image. In Experiment 1, we trained naive subjects via attentional highlighting on a fingerprint-matching task. Before and after training, we asked subjects to freely inspect images containing pairs of prints and determine whether the prints matched. Fixation sequences were automatically scored for the degree of expertise exhibited using a Bayesian discriminative model of novice and expert gaze behavior. Highlighted training causes gaze behavior to become more expert-like not only on the trained images but also on transfer images, indicating generalization of learning. In Experiment 2, to control for the possibility that the increase in expertise is due to mere exposure, we trained subjects via highlighting of fixation sequences from novices, not experts, and observed no transition toward expertise. In Experiment 3, to determine the specificity of the training effect, we trained subjects with expert fixation sequences from images other than the one being viewed, which preserves coarse-scale statistics of expert gaze but provides no information about fine-grain features. Observing at least a partial transition toward expertise, we obtain only weak evidence that the highlighting procedure facilitates the learning of critical local features. We discuss possible improvements to the highlighting procedure. PMID:26744839

  9. Using Highlighting to Train Attentional Expertise.

    PubMed

    Roads, Brett; Mozer, Michael C; Busey, Thomas A

    2016-01-01

    Acquiring expertise in complex visual tasks is time consuming. To facilitate the efficient training of novices on where to look in these tasks, we propose an attentional highlighting paradigm. Highlighting involves dynamically modulating the saliency of a visual image to guide attention along the fixation path of a domain expert who had previously viewed the same image. In Experiment 1, we trained naive subjects via attentional highlighting on a fingerprint-matching task. Before and after training, we asked subjects to freely inspect images containing pairs of prints and determine whether the prints matched. Fixation sequences were automatically scored for the degree of expertise exhibited using a Bayesian discriminative model of novice and expert gaze behavior. Highlighted training causes gaze behavior to become more expert-like not only on the trained images but also on transfer images, indicating generalization of learning. In Experiment 2, to control for the possibility that the increase in expertise is due to mere exposure, we trained subjects via highlighting of fixation sequences from novices, not experts, and observed no transition toward expertise. In Experiment 3, to determine the specificity of the training effect, we trained subjects with expert fixation sequences from images other than the one being viewed, which preserves coarse-scale statistics of expert gaze but provides no information about fine-grain features. Observing at least a partial transition toward expertise, we obtain only weak evidence that the highlighting procedure facilitates the learning of critical local features. We discuss possible improvements to the highlighting procedure.

  10. A fully actuated robotic assistant for MRI-guided prostate biopsy and brachytherapy

    NASA Astrophysics Data System (ADS)

    Li, Gang; Su, Hao; Shang, Weijian; Tokuda, Junichi; Hata, Nobuhiko; Tempany, Clare M.; Fischer, Gregory S.

    2013-03-01

    Intra-operative medical imaging enables incorporation of human experience and intelligence in a controlled, closed-loop fashion. Magnetic resonance imaging (MRI) is an ideal modality for surgical guidance of diagnostic and therapeutic procedures, with its ability to perform high resolution, real-time, high soft tissue contrast imaging without ionizing radiation. However, for most current image-guided approaches only static pre-operative images are accessible for guidance, which are unable to provide updated information during a surgical procedure. The high magnetic field, electrical interference, and limited access of closed-bore MRI render great challenges to developing robotic systems that can perform inside a diagnostic high-field MRI while obtaining interactively updated MR images. To overcome these limitations, we are developing a piezoelectrically actuated robotic assistant for actuated percutaneous prostate interventions under real-time MRI guidance. Utilizing a modular design, the system enables coherent and straight forward workflow for various percutaneous interventions, including prostate biopsy sampling and brachytherapy seed placement, using various needle driver configurations. The unified workflow compromises: 1) system hardware and software initialization, 2) fiducial frame registration, 3) target selection and motion planning, 4) moving to the target and performing the intervention (e.g. taking a biopsy sample) under live imaging, and 5) visualization and verification. Phantom experiments of prostate biopsy and brachytherapy were executed under MRI-guidance to evaluate the feasibility of the workflow. The robot successfully performed fully actuated biopsy sampling and delivery of simulated brachytherapy seeds under live MR imaging, as well as precise delivery of a prostate brachytherapy seed distribution with an RMS accuracy of 0.98mm.

  11. Perk Station – Percutaneous Surgery Training and Performance Measurement Platform

    PubMed Central

    Vikal, Siddharth; U-Thainual, Paweena; Carrino, John A.; Iordachita, Iulian; Fischer, Gregory S.; Fichtinger, Gabor

    2009-01-01

    Motivation Image-guided percutaneous (through the skin) needle-based surgery has become part of routine clinical practice in performing procedures such as biopsies, injections and therapeutic implants. A novice physician typically performs needle interventions under the supervision of a senior physician; a slow and inherently subjective training process that lacks objective, quantitative assessment of the surgical skill and performance[S1]. Shortening the learning curve and increasing procedural consistency are important factors in assuring high-quality medical care. Methods This paper describes a laboratory validation system, called Perk Station, for standardized training and performance measurement under different assistance techniques for needle-based surgical guidance systems. The initial goal of the Perk Station is to assess and compare different techniques: 2D image overlay, biplane laser guide, laser protractor and conventional freehand. The main focus of this manuscript is the planning and guidance software system developed on the 3D Slicer platform, a free, open source software package designed for visualization and analysis of medical image data. Results The prototype Perk Station has been successfully developed, the associated needle insertion phantoms were built, and the graphical user interface was fully implemented. The system was inaugurated in undergraduate teaching and a wide array of outreach activities. Initial results, experiences, ongoing activities and future plans are reported. PMID:19539446

  12. Enhanced Lesion Visualization in Image-Guided Noninvasive Surgery With Ultrasound Phased Arrays

    DTIC Science & Technology

    2001-10-25

    81, 1995. [4] N. Sanghvi et al., “Noninvasive surgery of prostate tissue by high-intensity focused ultrasound ,” IEEE Trans. UFFC, vol. 43, no. 6, pp...ENHANCED LESION VISUALIZATION IN IMAGE-GUIDED NONINVASIVE SURGERY WITH ULTRASOUND PHASED ARRAYS Hui Yao, Pornchai Phukpattaranont and Emad S. Ebbini...Department of Electrical and Computer Engineering University of Minnesota Minneapolis, MN 55455 Abstract- We describe dual-mode ultrasound phased

  13. Supervised guiding long-short term memory for image caption generation based on object classes

    NASA Astrophysics Data System (ADS)

    Wang, Jian; Cao, Zhiguo; Xiao, Yang; Qi, Xinyuan

    2018-03-01

    The present models of image caption generation have the problems of image visual semantic information attenuation and errors in guidance information. In order to solve these problems, we propose a supervised guiding Long Short Term Memory model based on object classes, named S-gLSTM for short. It uses the object detection results from R-FCN as supervisory information with high confidence, and updates the guidance word set by judging whether the last output matches the supervisory information. S-gLSTM learns how to extract the current interested information from the image visual se-mantic information based on guidance word set. The interested information is fed into the S-gLSTM at each iteration as guidance information, to guide the caption generation. To acquire the text-related visual semantic information, the S-gLSTM fine-tunes the weights of the network through the back-propagation of the guiding loss. Complementing guidance information at each iteration solves the problem of visual semantic information attenuation in the traditional LSTM model. Besides, the supervised guidance information in our model can reduce the impact of the mismatched words on the caption generation. We test our model on MSCOCO2014 dataset, and obtain better performance than the state-of-the- art models.

  14. Real-time magnetic resonance imaging-guided transcatheter aortic valve replacement.

    PubMed

    Miller, Justin G; Li, Ming; Mazilu, Dumitru; Hunt, Tim; Horvath, Keith A

    2016-05-01

    To demonstrate the feasibility of Real-time magnetic resonance imaging (rtMRI) guided transcatheter aortic valve replacement (TAVR) with an active guidewire and an MRI compatible valve delivery catheter system in a swine model. The CoreValve system was minimally modified to be MRI-compatible by replacing the stainless steel components with fluoroplastic resin and high-density polyethylene components. Eight swine weighing 60-90 kg underwent rtMRI-guided TAVR with an active guidewire through a left subclavian approach. Two imaging planes (long-axis view and short-axis view) were used simultaneously for real-time imaging during implantation. Successful deployment was performed without rapid ventricular pacing or cardiopulmonary bypass. Postdeployment images were acquired to evaluate the final valve position in addition to valvular and cardiac function. Our results show that the CoreValve can be easily and effectively deployed through a left subclavian approach using rtMRI guidance, a minimally modified valve delivery catheter system, and an active guidewire. This method allows superior visualization before deployment, thereby allowing placement of the valve with pinpoint accuracy. rtMRI has the added benefit of the ability to perform immediate postprocedural functional assessment, while eliminating the morbidity associated with radiation exposure, rapid ventricular pacing, contrast media renal toxicity, and a more invasive procedure. Use of a commercially available device brings this rtMRI-guided approach closer to clinical reality. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  15. 3D optical coherence tomography image registration for guiding cochlear implant insertion

    NASA Astrophysics Data System (ADS)

    Cheon, Gyeong-Woo; Jeong, Hyun-Woo; Chalasani, Preetham; Chien, Wade W.; Iordachita, Iulian; Taylor, Russell; Niparko, John; Kang, Jin U.

    2014-03-01

    In cochlear implant surgery, an electrode array is inserted into the cochlear canal to restore hearing to a person who is profoundly deaf or significantly hearing impaired. One critical part of the procedure is the insertion of the electrode array, which looks like a thin wire, into the cochlear canal. Although X-ray or computed tomography (CT) could be used as a reference to evaluate the pathway of the whole electrode array, there is no way to depict the intra-cochlear canal and basal turn intra-operatively to help guide insertion of the electrode array. Optical coherent tomography (OCT) is a highly effective way of visualizing internal structures of cochlea. Swept source OCT (SSOCT) having center wavelength of 1.3 micron and 2D Galvonometer mirrors was used to achieve 7-mm depth 3-D imaging. Graphics processing unit (GPU), OpenGL, C++ and C# were integrated for real-time volumetric rendering simultaneously. The 3D volume images taken by the OCT system were assembled and registered which could be used to guide a cochlear implant. We performed a feasibility study using both dry and wet temporal bones and the result is presented.

  16. Creative Visualization Activities.

    ERIC Educational Resources Information Center

    Fugitt, Eva D.

    1986-01-01

    Presents a series of classroom exercises and activities that stimulate children's creativity through the use of visualization. Discusses procedures for guided imagery and offers some examples of "trips" to imaginary places. Proposes visualization as a warm-up exercise before art lessons. (DR)

  17. Visualization of cortical, subcortical, and deep brain neural circuit dynamics during naturalistic mammalian behavior with head-mounted microscopes and chronically implanted lenses

    PubMed Central

    Resendez, Shanna L.; Jennings, Josh H.; Ung, Randall L.; Namboodiri, Vijay Mohan K.; Zhou, Zhe Charles; Otis, James M.; Nomura, Hiroshi; McHenry, Jenna A.; Kosyk, Oksana; Stuber, Garret D.

    2016-01-01

    Genetically encoded calcium indicators for visualizing dynamic cellular activity have greatly expanded our understanding of the brain. However, due to light scattering properties of the brain as well as the size and rigidity of traditional imaging technology, in vivo calcium imaging has been limited to superficial brain structures during head fixed behavioral tasks. This limitation can now be circumvented by utilizing miniature, integrated microscopes in conjunction with an implantable microendoscopic lens to guide light into and out of the brain, thus permitting optical access to deep brain (or superficial) neural ensembles during naturalistic behaviors. Here, we describe procedural steps to conduct such imaging studies using mice. However, we anticipate the protocol can be easily adapted for use in other small vertebrates. Successful completion of this protocol will permit cellular imaging of neuronal activity and the generation of data sets with sufficient statistical power to correlate neural activity with stimulus presentation, physiological state, and other aspects of complex behavioral tasks. This protocol takes 6–11 weeks to complete. PMID:26914316

  18. Real-Time flare detection using guided filter

    NASA Astrophysics Data System (ADS)

    Lin, Jiaben; Deng, Yuanyong; Yuan, Fei; Guo, Juan

    2017-04-01

    A procedure is introduced for the automatic detection of solar flare using full-disk solar images from Huairou Solar Observing Station (HSOS), National Astronomical Observatories of China. In image preprocessing, median filter is applied to remove the noises. And then we adopt guided filter, which is first introduced into the astronomical image detection, to enhance the edges of flares and restrain the solar limb darkening. Flares are then detected by modified Otsu algorithm and further threshold processing technique. Compared with other automatic detection procedure, the new procedure has some advantages such as real time and reliability as well as no need of image division and local threshold. Also, it reduces the amount of computation largely, which is benefited from the efficient guided filter algorithm. The procedure has been tested on one month sequences (December 2013) of HSOS full-disk solar images and the result of flares detection shows that the number of flares detected by our procedure is well consistent with the manual one.

  19. Interventional articular and para-articular knee procedures

    PubMed Central

    Lalam, Radhesh K; Winn, Naomi

    2016-01-01

    The knee is a common area of the body to undergo interventional procedures. This article discusses image-guided interventional issues specific to the knee area. The soft tissues in and around the knee are frequently affected by sport-related injuries and often need image-guided intervention. This article details the specific technical issues related to intervention in these soft tissues, including the iliotibial tract, fat pads, patellar tendon and other tendons, bursae and the meniscus. Most often, simple procedures such as injection and aspiration are performed without image guidance. Rarely image-guided diagnostic arthrography and therapeutic joint injections are necessary. The technique, indications and diagnostic considerations for arthrography are discussed in this article. Primary bone and soft-tissue tumours may involve the knee and adjacent soft tissues. Image-guided biopsies are frequently necessary for these lesions; this article details the technical issues related to image-guided biopsy around the knee. A number of newer ablation treatments are now available, including cryoablation, high-frequency ultrasound and microwave ablation. Radiofrequency ablation, however, still remains the most commonly employed ablation technique. The indications, technical and therapeutic considerations related to the application of this technique around the knee are discussed here. Finally, we briefly discuss some newer, but as of yet, unproven image-guided interventions for osteochondral lesions and Brodie's abscess. PMID:26682669

  20. Color image guided depth image super resolution using fusion filter

    NASA Astrophysics Data System (ADS)

    He, Jin; Liang, Bin; He, Ying; Yang, Jun

    2018-04-01

    Depth cameras are currently playing an important role in many areas. However, most of them can only obtain lowresolution (LR) depth images. Color cameras can easily provide high-resolution (HR) color images. Using color image as a guide image is an efficient way to get a HR depth image. In this paper, we propose a depth image super resolution (SR) algorithm, which uses a HR color image as a guide image and a LR depth image as input. We use the fusion filter of guided filter and edge based joint bilateral filter to get HR depth image. Our experimental results on Middlebury 2005 datasets show that our method can provide better quality in HR depth images both numerically and visually.

  1. Optimizing wavefront-guided corrections for highly aberrated eyes in the presence of registration uncertainty

    PubMed Central

    Shi, Yue; Queener, Hope M.; Marsack, Jason D.; Ravikumar, Ayeswarya; Bedell, Harold E.; Applegate, Raymond A.

    2013-01-01

    Dynamic registration uncertainty of a wavefront-guided correction with respect to underlying wavefront error (WFE) inevitably decreases retinal image quality. A partial correction may improve average retinal image quality and visual acuity in the presence of registration uncertainties. The purpose of this paper is to (a) develop an algorithm to optimize wavefront-guided correction that improves visual acuity given registration uncertainty and (b) test the hypothesis that these corrections provide improved visual performance in the presence of these uncertainties as compared to a full-magnitude correction or a correction by Guirao, Cox, and Williams (2002). A stochastic parallel gradient descent (SPGD) algorithm was used to optimize the partial-magnitude correction for three keratoconic eyes based on measured scleral contact lens movement. Given its high correlation with logMAR acuity, the retinal image quality metric log visual Strehl was used as a predictor of visual acuity. Predicted values of visual acuity with the optimized corrections were validated by regressing measured acuity loss against predicted loss. Measured loss was obtained from normal subjects viewing acuity charts that were degraded by the residual aberrations generated by the movement of the full-magnitude correction, the correction by Guirao, and optimized SPGD correction. Partial-magnitude corrections optimized with an SPGD algorithm provide at least one line improvement of average visual acuity over the full magnitude and the correction by Guirao given the registration uncertainty. This study demonstrates that it is possible to improve the average visual acuity by optimizing wavefront-guided correction in the presence of registration uncertainty. PMID:23757512

  2. Threat captures attention but does not affect learning of contextual regularities.

    PubMed

    Yamaguchi, Motonori; Harwood, Sarah L

    2017-04-01

    Some of the stimulus features that guide visual attention are abstract properties of objects such as potential threat to one's survival, whereas others are complex configurations such as visual contexts that are learned through past experiences. The present study investigated the two functions that guide visual attention, threat detection and learning of contextual regularities, in visual search. Search arrays contained images of threat and non-threat objects, and their locations were fixed on some trials but random on other trials. Although they were irrelevant to the visual search task, threat objects facilitated attention capture and impaired attention disengagement. Search time improved for fixed configurations more than for random configurations, reflecting learning of visual contexts. Nevertheless, threat detection had little influence on learning of the contextual regularities. The results suggest that factors guiding visual attention are different from factors that influence learning to guide visual attention.

  3. Visual Literacy for Libraries: A Practical, Standards­-Based Guide

    ERIC Educational Resources Information Center

    Brown, Nicole E.; Bussert, Kaila; Hattwig, Denise; Medaille, Ann

    2016-01-01

    The importance of images and visual media in today's culture is changing what it means to be literate in the 21st century. Digital technologies have made it possible for almost anyone to create and share visual media. Yet the pervasiveness of images and visual media does not necessarily mean that individuals are able to critically view, use, and…

  4. Image-guided endobronchial ultrasound

    NASA Astrophysics Data System (ADS)

    Higgins, William E.; Zang, Xiaonan; Cheirsilp, Ronnarit; Byrnes, Patrick; Kuhlengel, Trevor; Bascom, Rebecca; Toth, Jennifer

    2016-03-01

    Endobronchial ultrasound (EBUS) is now recommended as a standard procedure for in vivo verification of extraluminal diagnostic sites during cancer-staging bronchoscopy. Yet, physicians vary considerably in their skills at using EBUS effectively. Regarding existing bronchoscopy guidance systems, studies have shown their effectiveness in the lung-cancer management process. With such a system, a patient's X-ray computed tomography (CT) scan is used to plan a procedure to regions of interest (ROIs). This plan is then used during follow-on guided bronchoscopy. Recent clinical guidelines for lung cancer, however, also dictate using positron emission tomography (PET) imaging for identifying suspicious ROIs and aiding in the cancer-staging process. While researchers have attempted to use guided bronchoscopy systems in tandem with PET imaging and EBUS, no true EBUS-centric guidance system exists. We now propose a full multimodal image-based methodology for guiding EBUS. The complete methodology involves two components: 1) a procedure planning protocol that gives bronchoscope movements appropriate for live EBUS positioning; and 2) a guidance strategy and associated system graphical user interface (GUI) designed for image-guided EBUS. We present results demonstrating the operation of the system.

  5. Image-guided laser projection for port placement in minimally invasive surgery.

    PubMed

    Marmurek, Jonathan; Wedlake, Chris; Pardasani, Utsav; Eagleson, Roy; Peters, Terry

    2006-01-01

    We present an application of an augmented reality laser projection system in which procedure-specific optimal incision sites, computed from pre-operative image acquisition, are superimposed on a patient to guide port placement in minimally invasive surgery. Tests were conducted to evaluate the fidelity of computed and measured port configurations, and to validate the accuracy with which a surgical tool-tip can be placed at an identified virtual target. A high resolution volumetric image of a thorax phantom was acquired using helical computed tomography imaging. Oriented within the thorax, a phantom organ with marked targets was visualized in a virtual environment. A graphical interface enabled marking the locations of target anatomy, and calculation of a grid of potential port locations along the intercostal rib lines. Optimal configurations of port positions and tool orientations were determined by an objective measure reflecting image-based indices of surgical dexterity, hand-eye alignment, and collision detection. Intra-operative registration of the computed virtual model and the phantom anatomy was performed using an optical tracking system. Initial trials demonstrated that computed and projected port placement provided direct access to target anatomy with an accuracy of 2 mm.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brun, E., E-mail: emmanuel.brun@esrf.fr; Grandl, S.; Sztrókay-Gaul, A.

    Purpose: Phase contrast computed tomography has emerged as an imaging method, which is able to outperform present day clinical mammography in breast tumor visualization while maintaining an equivalent average dose. To this day, no segmentation technique takes into account the specificity of the phase contrast signal. In this study, the authors propose a new mathematical framework for human-guided breast tumor segmentation. This method has been applied to high-resolution images of excised human organs, each of several gigabytes. Methods: The authors present a segmentation procedure based on the viscous watershed transform and demonstrate the efficacy of this method on analyzer basedmore » phase contrast images. The segmentation of tumors inside two full human breasts is then shown as an example of this procedure’s possible applications. Results: A correct and precise identification of the tumor boundaries was obtained and confirmed by manual contouring performed independently by four experienced radiologists. Conclusions: The authors demonstrate that applying the watershed viscous transform allows them to perform the segmentation of tumors in high-resolution x-ray analyzer based phase contrast breast computed tomography images. Combining the additional information provided by the segmentation procedure with the already high definition of morphological details and tissue boundaries offered by phase contrast imaging techniques, will represent a valuable multistep procedure to be used in future medical diagnostic applications.« less

  7. Real-time visualization of ultrasound-guided retrobulbar blockade: an imaging study.

    PubMed

    Luyet, C; Eichenberger, U; Moriggl, B; Remonda, L; Greif, R

    2008-12-01

    Retrobulbar anaesthesia allows eye surgery in awake patients. Severe complications of the blind techniques are reported. Ultrasound-guided needle introduction and direct visualization of the spread of local anaesthetic may improve quality and safety of retrobulbar anaesthesia. Therefore, we developed a new ultrasound-guided technique using human cadavers. In total, 20 blocks on both sides in 10 embalmed human cadavers were performed. Using a small curved array transducer and a long-axis approach, a 22 G short bevel needle was introduced under ultrasound guidance lateral and caudal of the eyeball until the needle tip was seen 2 mm away from the optic nerve. At this point, 2 ml of contrast dye as a substitute for local anaesthetic was injected. Immediately after the injection, the spread of the contrast dye was documented by means of CT scans performed in each cadaver. The CT scans showed the distribution of the contrast dye in the muscle cone and behind the posterior sclera in all but one case. No contrast dye was found inside the optic nerve or inside the eyeball. In one case, there could be an additional trace of contrast dye behind the orbita. Our new ultrasound-guided technique has the potential to improve safety and efficacy of the procedure by direct visualization of the needle placement and the distribution of the injected fluid. Furthermore, the precise injection near the optic nerve could lead to a reduction of the amount of the local anaesthetic needed with fewer related complications.

  8. Toward computer-assisted image-guided congenital heart defect repair: an initial phantom analysis.

    PubMed

    Kwartowitz, David M; Mefleh, Fuad N; Baker, G Hamilton

    2017-10-01

    Radiation exposure in interventional cardiology is an important consideration, due to risk of cancer and other morbidity to the patient and clinical staff. Cardiac catheterizations rely heavily on fluoroscopic imaging exposing both patient and clinician to ionizing radiation. An image-guided surgery system capable of facilitating cardiac catheterizations was developed and tested to evaluate dose reduction. Several electromagnetically tracked tools were constructed specifically a 7-Fr catheter with five 5-degree-of-freedom magnetic seeds. Catheter guidance was accomplished using our image guidance system Kit for Navigation by Image-Focused Exploration and fluoroscopy alone. A cardiac phantom was designed and 3D printed to validate the image guidance procedure. In mock procedures, an expert clinician guided and deployed an occluder across the septal defect of the phantom heart. The image guidance method resulted in a dose of 1.26 mSv of radiation dose per procedure, while traditional guidance resulted in a dose of 3.33 mSv. Average overall dose savings for the image-guided method was nearly 2.07 mSv or 62 %. The work showed significant ([Formula: see text]) decrease in radiation dose with use of image guidance methods at the expense of a modest increase in procedure time. This study lays the groundwork for further exploration of image guidance applications in pediatric cardiology.

  9. Optical coherence tomography for image-guided dermal filler injection and biomechanical evaluation

    NASA Astrophysics Data System (ADS)

    Singh, Manmohan; Wang, Shang; Yee, Richard W.; Han, Zhaolong; Aglyamov, Salavat R.; Larin, Kirill V.

    2017-02-01

    Dermal fillers are a very popular anti-ag ing treatment with estimated sales in the billions of dollars and millions of procedures performed. As the aging population continues to grow, these figures are only e xpected to increase. Dermal fillers have various compositions depending on their intended applicati on. Reactions to dermal fillers can be severe, such as ischemic events and filler migration to the eyes. Howe ver, these adverse reactions are rare. Nevertheless, the capability to perform imag e-guided filler injections would minimize th e risk of such reacti ons. In addition, the biomechanical properties of various fillers have been evalua ted, but there has been no investigation on the effects of filler on the biomechanical properties of skin. In this work, we utilize optical cohe rence tomography (OCT) for visualizing dermal filler injections with micrometer-scale sp atial resolution. In addition, we utilize noncontact optical coherence elastography (OCE) to quantify the changes in the biomechan ical properties of pig skin after the dermal filler injections. OCT was successfully able to visualize the dermal filler injecti on process, and OCE showed that the viscoelasticity of the pig skin was increased locally at the filler injection sites. OCT may be able to provide real-time image guidance in 3D, and when combined with functional OCT techniques such as optical microangiography, could be used to avoid blood vessels during the injection.

  10. Newly-developed, forward-viewing echoendoscope: a comparative pilot study to the standard echoendoscope in the imaging of abdominal organs and feasibility of endoscopic ultrasound-guided interventions.

    PubMed

    Iwashita, Takuji; Nakai, Yousuke; Lee, John G; Park, Do Hyun; Muthusamy, V Raman; Chang, Kenneth J

    2012-02-01

    Multiple diagnostic and therapeutic endoscopic ultrasound (EUS) procedures have been widely performed using a standard oblique-viewing (OV) curvilinear array (CLA) echoendoscope. Recently, a new, forward-viewing (FV) CLA was developed, with the advantages of improved endoscopic viewing and manipulation of devices. However, the FV-CLA echoendoscope has a narrower ultrasound scanning field, and lacks an elevator, which might represent obstacles for clinical use. The aim of this study was to compare the FV-CLA echoendoscope to the OV-CLA echoendoscope for EUS imaging of abdominal organs, and to assess the feasibility of EUS-guided interventions using the FV-CLA echoendoscope. EUS examinations were first performed and recorded using the OV-CLA echoendoscope, followed immediately by the FV-CLA echoendoscope. Video recordings were then assessed by two independent endosonographers in a blinded fashion. The EUS visualization and image quality of specific abdominal organs/structures were scored. Any indicated fine-needle aspiration (FNA) or intervention was performed using the FV-CLA echoendoscope, with the OV-CLA echoendoscope as salvage upon failure. A total of 21 patients were examined in the study. Both echoendoscopes had similar visualization and image quality for all organs/structures, except the common hepatic duct (CHD), which was seen significantly better with the FV-CLA echoendoscope. EUS interventions were conducted in eight patients, including FNA of pancreatic mass (3), pancreatic cyst (3), and cystgastrostomy (2). The FV-CLA echoendoscope was successful in seven patients. One failed FNA of the pancreatic head cyst was salvaged using the OV-CLA echoendoscope. There were no differences between the FV-CLA echoendoscope and the OV-CLA echoendoscope in visualization or image quality on upper EUS, except for the superior image quality of CHD using the FV-CLA echoendoscope. Therefore, the disadvantages of the FV-CLA echoendoscope appear minimal in light of the potential advantages. © 2011 Journal of Gastroenterology and Hepatology Foundation and Blackwell Publishing Asia Pty Ltd.

  11. Characterization and evaluation of ionizing and non-ionizing imaging systems used in state of the art image-guided radiation therapy techniques

    NASA Astrophysics Data System (ADS)

    Stanley, Dennis Nichols

    With the growing incidence of cancer worldwide, the need for effective cancer treatment is paramount. Currently, radiation therapy exists as one of the few effective, non-invasive methods of reducing tumor size and has the capability for the elimination of localized tumors. Radiation therapy utilizes non-invasive external radiation to treat localized cancers but to be effective, physicians must be able to visualize and monitor the internal anatomy and target displacements. Image-Guided Radiation Therapy frequently utilizes planar and volumetric imaging during a course of radiation therapy to improve the precision and accuracy of the delivered treatment to the internal anatomy. Clinically, visualization of the internal anatomy allows physicians to refine the treatment to include as little healthy tissue as possible. This not only increases the effectiveness of treatment by damaging only the tumor but also increases the quality of life for the patient by decreasing the amount of healthy tissue damaged. Image-Guided Radiation Therapy is commonly used to treat tumors in areas of the body that are prone to movement, such as the lungs, liver, and prostate, as well as tumors located close to critical organs and tissues such as the tumors in the brain and spinal cord. Image-Guided Radiation Therapy can utilize both ionizing modalities, like x-ray based planar radiography and cone-beam CT, and nonionizing modalities like MRI, ultrasound and video-based optical scanning systems. Currently ionizing modalities are most commonly utilized for their ability to visualize and monitor internal anatomy but cause an increase to the total dose to the patient. Nonionizing imaging modalities allow frequent/continuous imaging without the increase in dose; however, they are just beginning to be clinically implemented in radiation oncology. With the growing prevalence and variety of Image-Guided Radiation Therapy imaging modalities the ability to evaluate the overall image quality, monitor the stability of the imaging systems and characterize each system are important to ensuring the consistency and effectiveness of the overall treatment. Image-Guided Radiation Therapy quality assurance allows a method of quantifying the accuracy and stability of the imaging systems. Understanding how the ionizing imaging systems operate and change over time allows for a more effective overall treatment and will be the focus of the first step of this project. In each of the first three aims, different ionizing imaging modalities will be evaluated for their temporal stability and a record of the determined tolerance level will be reported. The Second step of this project will be a characterization of the accuracy and performance of the new C-Rad CatalystHD a video-based, surface-imaging guided patient localization system. The catalyst will be analyzed for it accuracy of setup and patient positing, intra- and inter- fraction motion detection as well as its respiratory gating capabilities. The final step of this project will be to use the well-established accuracy of the XVI volumetric imaging system as a benchmark to assess the accuracy of the C-Rad CatalystHD system for use in pretreatment patient position verification for cranial stereotactic procedures. The treatment of brain lesions generally requires a very high degree of precision due to relatively small target sizes, close proximity to eloquent areas of the brain, and large, ablative doses being delivered. Stringent accuracy in imaging is needed to verify and monitor the correct spatial delivery of radiation throughout treatment. In order to investigate if the CatalystHD system is a capable imaging system for such deliveries, the system will need to be assessed and benchmarked against the XVI in a phantom geometry. By doing so, the currently unproven utility of the CatalystHD system for cranial stereotactic delivery may be established. (Abstract shortened by ProQuest.).

  12. Fundamental limits of image registration performance: Effects of image noise and resolution in CT-guided interventions.

    PubMed

    Ketcha, M D; de Silva, T; Han, R; Uneri, A; Goerres, J; Jacobson, M; Vogt, S; Kleinszig, G; Siewerdsen, J H

    2017-02-11

    In image-guided procedures, image acquisition is often performed primarily for the task of geometrically registering information from another image dataset, rather than detection / visualization of a particular feature. While the ability to detect a particular feature in an image has been studied extensively with respect to image quality characteristics (noise, resolution) and is an ongoing, active area of research, comparatively little has been accomplished to relate such image quality characteristics to registration performance. To establish such a framework, we derived Cramer-Rao lower bounds (CRLB) for registration accuracy, revealing the underlying dependencies on image variance and gradient strength. The CRLB was analyzed as a function of image quality factors (in particular, dose) for various similarity metrics and compared to registration accuracy using CT images of an anthropomorphic head phantom at various simulated dose levels. Performance was evaluated in terms of root mean square error (RMSE) of the registration parameters. Analysis of the CRLB shows two primary dependencies: 1) noise variance (related to dose); and 2) sum of squared image gradients (related to spatial resolution and image content). Comparison of the measured RMSE to the CRLB showed that the best registration method, RMSE achieved the CRLB to within an efficiency factor of 0.21, and optimal estimators followed the predicted inverse proportionality between registration performance and radiation dose. Analysis of the CRLB for image registration is an important step toward understanding and evaluating an intraoperative imaging system with respect to a registration task. While the CRLB is optimistic in absolute performance, it reveals a basis for relating the performance of registration estimators as a function of noise content and may be used to guide acquisition parameter selection (e.g., dose) for purposes of intraoperative registration.

  13. The Acoustic Lens Design and in Vivo Use of a Multifunctional Catheter Combining Intracardiac Ultrasound Imaging and Electrophysiology Sensing

    PubMed Central

    Stephens, Douglas N.; Cannata, Jonathan; Liu, Ruibin; Zhao, Jian Zhong; Shung, K. Kirk; Nguyen, Hien; Chia, Raymond; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai E.; Mahajan, Aman; Shivkumar, Kalyanam; Kim, Kang; O’Donnell, Matthew; Sahn, David

    2009-01-01

    A multifunctional 9F intracardiac imaging and electrophysiology mapping catheter was developed and tested to help guide diagnostic and therapeutic intracardiac electrophysiology (EP) procedures. The catheter tip includes a 7.25-MHz, 64-element, side-looking phased array for high resolution sector scanning. Multiple electrophysiology mapping sensors were mounted as ring electrodes near the array for electrocardiographic synchronization of ultrasound images. The catheter array elevation beam performance in particular was investigated. An acoustic lens for the distal tip array designed with a round cross section can produce an acceptable elevation beam shape; however, the velocity of sound in the lens material should be approximately 155 m/s slower than in tissue for the best beam shape and wide bandwidth performance. To help establish the catheter’s unique ability for integration with electrophysiology interventional procedures, it was used in vivo in a porcine animal model, and demonstrated both useful intracardiac echocardiographic visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheter also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. PMID:18407850

  14. City: Images of America. Elementary Version.

    ERIC Educational Resources Information Center

    Franklin, Edward; And Others

    Designed to accompany an audiovisual filmstrip series devoted to presenting a visual history of life in America, this guide contains an elementary social studies (grades 2-6) unit on the American city over the last century. Using authentic visuals including paintings, posters, advertising, documentary photography, and cartoons, the guide offers…

  15. Simple Smartphone-Based Guiding System for Visually Impaired People

    PubMed Central

    Lin, Bor-Shing; Lee, Cheng-Che; Chiang, Pei-Ying

    2017-01-01

    Visually impaired people are often unaware of dangers in front of them, even in familiar environments. Furthermore, in unfamiliar environments, such people require guidance to reduce the risk of colliding with obstacles. This study proposes a simple smartphone-based guiding system for solving the navigation problems for visually impaired people and achieving obstacle avoidance to enable visually impaired people to travel smoothly from a beginning point to a destination with greater awareness of their surroundings. In this study, a computer image recognition system and smartphone application were integrated to form a simple assisted guiding system. Two operating modes, online mode and offline mode, can be chosen depending on network availability. When the system begins to operate, the smartphone captures the scene in front of the user and sends the captured images to the backend server to be processed. The backend server uses the faster region convolutional neural network algorithm or the you only look once algorithm to recognize multiple obstacles in every image, and it subsequently sends the results back to the smartphone. The results of obstacle recognition in this study reached 60%, which is sufficient for assisting visually impaired people in realizing the types and locations of obstacles around them. PMID:28608811

  16. Simple Smartphone-Based Guiding System for Visually Impaired People.

    PubMed

    Lin, Bor-Shing; Lee, Cheng-Che; Chiang, Pei-Ying

    2017-06-13

    Visually impaired people are often unaware of dangers in front of them, even in familiar environments. Furthermore, in unfamiliar environments, such people require guidance to reduce the risk of colliding with obstacles. This study proposes a simple smartphone-based guiding system for solving the navigation problems for visually impaired people and achieving obstacle avoidance to enable visually impaired people to travel smoothly from a beginning point to a destination with greater awareness of their surroundings. In this study, a computer image recognition system and smartphone application were integrated to form a simple assisted guiding system. Two operating modes, online mode and offline mode, can be chosen depending on network availability. When the system begins to operate, the smartphone captures the scene in front of the user and sends the captured images to the backend server to be processed. The backend server uses the faster region convolutional neural network algorithm or the you only look once algorithm to recognize multiple obstacles in every image, and it subsequently sends the results back to the smartphone. The results of obstacle recognition in this study reached 60%, which is sufficient for assisting visually impaired people in realizing the types and locations of obstacles around them.

  17. Novel System for Real-Time Integration of 3-D Echocardiography and Fluoroscopy for Image-Guided Cardiac Interventions: Preclinical Validation and Clinical Feasibility Evaluation.

    PubMed

    Arujuna, Aruna V; Housden, R James; Ma, Yingliang; Rajani, Ronak; Gao, Gang; Nijhof, Niels; Cathier, Pascal; Bullens, Roland; Gijsbers, Geert; Parish, Victoria; Kapetanakis, Stamatis; Hancock, Jane; Rinaldi, C Aldo; Cooklin, Michael; Gill, Jaswinder; Thomas, Martyn; O'neill, Mark D; Razavi, Reza; Rhode, Kawal S

    2014-01-01

    Real-time imaging is required to guide minimally invasive catheter-based cardiac interventions. While transesophageal echocardiography allows for high-quality visualization of cardiac anatomy, X-ray fluoroscopy provides excellent visualization of devices. We have developed a novel image fusion system that allows real-time integration of 3-D echocardiography and the X-ray fluoroscopy. The system was validated in the following two stages: 1) preclinical to determine function and validate accuracy; and 2) in the clinical setting to assess clinical workflow feasibility and determine overall system accuracy. In the preclinical phase, the system was assessed using both phantom and porcine experimental studies. Median 2-D projection errors of 4.5 and 3.3 mm were found for the phantom and porcine studies, respectively. The clinical phase focused on extending the use of the system to interventions in patients undergoing either atrial fibrillation catheter ablation (CA) or transcatheter aortic valve implantation (TAVI). Eleven patients were studied with nine in the CA group and two in the TAVI group. Successful real-time view synchronization was achieved in all cases with a calculated median distance error of 2.2 mm in the CA group and 3.4 mm in the TAVI group. A standard clinical workflow was established using the image fusion system. These pilot data confirm the technical feasibility of accurate real-time echo-fluoroscopic image overlay in clinical practice, which may be a useful adjunct for real-time guidance during interventional cardiac procedures.

  18. Automatic detection of solar features in HSOS full-disk solar images using guided filter

    NASA Astrophysics Data System (ADS)

    Yuan, Fei; Lin, Jiaben; Guo, Jingjing; Wang, Gang; Tong, Liyue; Zhang, Xinwei; Wang, Bingxiang

    2018-02-01

    A procedure is introduced for the automatic detection of solar features using full-disk solar images from Huairou Solar Observing Station (HSOS), National Astronomical Observatories of China. In image preprocessing, median filter is applied to remove the noises. Guided filter is adopted to enhance the edges of solar features and restrain the solar limb darkening, which is first introduced into the astronomical target detection. Then specific features are detected by Otsu algorithm and further threshold processing technique. Compared with other automatic detection procedures, our procedure has some advantages such as real time and reliability as well as no need of local threshold. Also, it reduces the amount of computation largely, which is benefited from the efficient guided filter algorithm. The procedure has been tested on one month sequences (December 2013) of HSOS full-disk solar images and the result shows that the number of features detected by our procedure is well consistent with the manual one.

  19. Shade matching assisted by digital photography and computer software.

    PubMed

    Schropp, Lars

    2009-04-01

    To evaluate the efficacy of digital photographs and graphic computer software for color matching compared to conventional visual matching. The shade of a tab from a shade guide (Vita 3D-Master Guide) placed in a phantom head was matched to a second guide of the same type by nine observers. This was done for twelve selected shade tabs (tests). The shade-matching procedure was performed visually in a simulated clinic environment and with digital photographs, and the time spent for both procedures was recorded. An alternative arrangement of the shade tabs was used in the digital photographs. In addition, a graphic software program was used for color analysis. Hue, chroma, and lightness values of the test tab and all tabs of the second guide were derived from the digital photographs. According to the CIE L*C*h* color system, the color differences between the test tab and tabs of the second guide were calculated. The shade guide tab that deviated least from the test tab was determined to be the match. Shade matching performance by means of graphic software was compared with the two visual methods and tested by Chi-square tests (alpha= 0.05). Eight of twelve test tabs (67%) were matched correctly by the computer software method. This was significantly better (p < 0.02) than the performance of the visual shade matching methods conducted in the simulated clinic (32% correct match) and with photographs (28% correct match). No correlation between time consumption for the visual shade matching methods and frequency of correct match was observed. Shade matching assisted by digital photographs and computer software was significantly more reliable than by conventional visual methods.

  20. Toward dynamic lumbar punctures guidance based on single element synthetic tracked aperture ultrasound imaging

    NASA Astrophysics Data System (ADS)

    Zhang, Haichong K.; Lin, Melissa; Kim, Younsu; Paredes, Mateo; Kannan, Karun; Patel, Nisu; Moghekar, Abhay; Durr, Nicholas J.; Boctor, Emad M.

    2017-03-01

    Lumbar punctures (LPs) are interventional procedures used to collect cerebrospinal fluid (CSF), a bodily fluid needed to diagnose central nervous system disorders. Most lumbar punctures are performed blindly without imaging guidance. Because the target window is small, physicians can only accurately palpate the appropriate space about 30% of the time and perform a successful procedure after an average of three attempts. Although various forms of imaging based guidance systems have been developed to aid in this procedure, these systems complicate the procedure by including independent image modalities and requiring image-to-needle registration to guide the needle insertion. Here, we propose a simple and direct needle insertion platform utilizing a single ultrasound element within the needle through dynamic sensing and imaging. The needle-shaped ultrasound transducer can not only sense the distance between the tip and a potential obstacle such as bone, but also visually locate structures by combining transducer location tracking and back projection based tracked synthetic aperture beam-forming algorithm. The concept of the system was validated through simulation first, which revealed the tolerance to realistic error. Then, the initial prototype of the single element transducer was built into a 14G needle, and was mounted on a holster equipped with a rotation tracking encoder. We experimentally evaluated the system using a metal wire phantom mimicking high reflection bone structures and an actual spine bone phantom with both the controlled motion and freehand scanning. An ultrasound image corresponding to the model phantom structure was reconstructed using the beam-forming algorithm, and the resolution was improved compared to without beam-forming. These results demonstrated the proposed system has the potential to be used as an ultrasound imaging system for lumbar puncture procedures.

  1. Multifunctional nanoparticles as a tissue adhesive and an injectable marker for image-guided procedures

    NASA Astrophysics Data System (ADS)

    Shin, Kwangsoo; Choi, Jin Woo; Ko, Giho; Baik, Seungmin; Kim, Dokyoon; Park, Ok Kyu; Lee, Kyoungbun; Cho, Hye Rim; Han, Sang Ihn; Lee, Soo Hong; Lee, Dong Jun; Lee, Nohyun; Kim, Hyo-Cheol; Hyeon, Taeghwan

    2017-07-01

    Tissue adhesives have emerged as an alternative to sutures and staples for wound closure and reconnection of injured tissues after surgery or trauma. Owing to their convenience and effectiveness, these adhesives have received growing attention particularly in minimally invasive procedures. For safe and accurate applications, tissue adhesives should be detectable via clinical imaging modalities and be highly biocompatible for intracorporeal procedures. However, few adhesives meet all these requirements. Herein, we show that biocompatible tantalum oxide/silica core/shell nanoparticles (TSNs) exhibit not only high contrast effects for real-time imaging but also strong adhesive properties. Furthermore, the biocompatible TSNs cause much less cellular toxicity and less inflammation than a clinically used, imageable tissue adhesive (that is, a mixture of cyanoacrylate and Lipiodol). Because of their multifunctional imaging and adhesive property, the TSNs are successfully applied as a hemostatic adhesive for minimally invasive procedures and as an immobilized marker for image-guided procedures.

  2. Electron microscopy for ultrastructural analysis and protein localization in Saccharomyces cerevisiae

    PubMed Central

    Frankl, Andri; Mari, Muriel; Reggiori, Fulvio

    2015-01-01

    The yeast Saccharomyces cerevisiae is a key model system for studying of a multitude of cellular processes because of its amenability to genetics, molecular biology and biochemical procedures. Ultrastructural examinations of this organism, though, are traditionally difficult because of the presence of a thick cell wall and the high density of cytoplasmic proteins. A series of recent methodological and technical developments, however, has revived interest in morphological analyses of yeast (e.g. 123). Here we present a review of established and new methods, from sample preparation to imaging, for the ultrastructural analysis of S. cerevisiae. We include information for the use of different fixation methods, embedding procedures, approaches for contrast enhancement, and sample visualization techniques, with references to successful examples. The goal of this review is to guide researchers that want to investigate a particular process at the ultrastructural level in yeast by aiding in the selection of the most appropriate approach to visualize a specific structure or subcellular compartment. PMID:28357267

  3. Ultrasound-Guided Elbow Procedures.

    PubMed

    Sussman, Walter I; Williams, Christopher J; Mautner, Ken

    2016-08-01

    High-resolution ultrasonography can help clinicians visualize key anatomic structures of the elbow and guide periarticular and intra-articular injections. Historically, most procedures done around the elbow have been done using landmark guidance, and few studies have reported the accuracy of ultrasonography-guided injections in the elbow region. This article reviews common musculoskeletal disorders about the elbow that can be evaluated with ultrasonography, reviews the literature on ultrasonography-guided injections of the elbow region, and describes the senior author's preferred approach for the most commonly performed elbow region injections. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Robot-assisted real-time magnetic resonance image-guided transcatheter aortic valve replacement.

    PubMed

    Miller, Justin G; Li, Ming; Mazilu, Dumitru; Hunt, Tim; Horvath, Keith A

    2016-05-01

    Real-time magnetic resonance imaging (rtMRI)-guided transcatheter aortic valve replacement (TAVR) offers improved visualization, real-time imaging, and pinpoint accuracy with device delivery. Unfortunately, performing a TAVR in a MRI scanner can be a difficult task owing to limited space and an awkward working environment. Our solution was to design a MRI-compatible robot-assisted device to insert and deploy a self-expanding valve from a remote computer console. We present our preliminary results in a swine model. We used an MRI-compatible robotic arm and developed a valve delivery module. A 12-mm trocar was inserted in the apex of the heart via a subxiphoid incision. The delivery device and nitinol stented prosthesis were mounted on the robot. Two continuous real-time imaging planes provided a virtual real-time 3-dimensional reconstruction. The valve was deployed remotely by the surgeon via a graphic user interface. In this acute nonsurvival study, 8 swine underwent robot-assisted rtMRI TAVR for evaluation of feasibility. Device deployment took a mean of 61 ± 5 seconds. Postdeployment necropsy was performed to confirm correlations between imaging and actual valve positions. These results demonstrate the feasibility of robotic-assisted TAVR using rtMRI guidance. This approach may eliminate some of the challenges of performing a procedure while working inside of an MRI scanner, and may improve the success of TAVR. It provides superior visualization during the insertion process, pinpoint accuracy of deployment, and, potentially, communication between the imaging device and the robotic module to prevent incorrect or misaligned deployment. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  5. Food: Images of America. Social Studies Unit, Elementary Grades 2-6.

    ERIC Educational Resources Information Center

    Franklin, Edward; And Others

    Designed to accompany an audiovisual filmstrip series devoted to presenting a visual history of life in America, this guide contains an elementary school (grades 2-6) unit on American food over the last century. Using authentic visuals including paintings, advertising, label art, documentary photography, and a movie still, the guide offers…

  6. MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement.

    PubMed

    Fischer, Gregory S; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; Dimaio, Simon P; Tempany, Clare M; Hata, Nobuhiko; Fichtinger, Gabor

    2008-06-01

    Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intraprostatic needle placement inside closed high-field MRI scanners. MRI compatibility of the robot has been evaluated under 3T MRI using standard prostate imaging sequences and average SNR loss is limited to 5%. Needle alignment accuracy of the robot under servo pneumatic control is better than 0.94 mm rms per axis. The complete system workflow has been evaluated in phantom studies with accurate visualization and targeting of five out of five 1 cm targets. The paper explains the robot mechanism and controller design, the system integration, and presents results of preliminary evaluation of the system.

  7. Multimodality Image Fusion-Guided Procedures: Technique, Accuracy, and Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abi-Jaoudeh, Nadine, E-mail: naj@mail.nih.gov; Kruecker, Jochen, E-mail: jochen.kruecker@philips.com; Kadoury, Samuel, E-mail: samuel.kadoury@polymtl.ca

    2012-10-15

    Personalized therapies play an increasingly critical role in cancer care: Image guidance with multimodality image fusion facilitates the targeting of specific tissue for tissue characterization and plays a role in drug discovery and optimization of tailored therapies. Positron-emission tomography (PET), magnetic resonance imaging (MRI), and contrast-enhanced computed tomography (CT) may offer additional information not otherwise available to the operator during minimally invasive image-guided procedures, such as biopsy and ablation. With use of multimodality image fusion for image-guided interventions, navigation with advanced modalities does not require the physical presence of the PET, MRI, or CT imaging system. Several commercially available methodsmore » of image-fusion and device navigation are reviewed along with an explanation of common tracking hardware and software. An overview of current clinical applications for multimodality navigation is provided.« less

  8. [Augmented reality for image guided therapy (ARIGT) of kidney tumor during nephron sparing surgery (NSS): animal model and clinical approach].

    PubMed

    Drewniak, Tomasz; Rzepecki, Maciej; Juszczak, Kajetan; Kwiatek, Wojciech; Bielecki, Jakub; Zieliński, Krzysztof; Ruta, Andrzej; Czekierda, Łukasz; Moczulskis, Zbigniew

    2011-01-01

    The main problem in nephron sparing surgery (NSS) is to preserve renal tumors oncological purity during the removal of the tumor with a margin of macroscopically unchanged kidney tissue while keeping the largest possible amount of normal parenchyma of the operated kidney. The development of imaging techniques, in particular IGT (Image Guided Therapy) allows precise imaging of the surgical field and, therefore, is essential in improving the effectiveness of NSS (increase of nephron sparing with the optimal radicality). The aim of this study was to develop a method of the three-dimensional (3D) imaging of the kidney tumor and its lodge in the operated kidney using 3D laser scanner during NSS procedure. Additionally, the animal model of visualization was developed. The porcine kidney model was used to test the set built up with HD cameras and linear laser scanner connected to a laptop with graphic software (David Laser Scanner, Germany) showing the surface of the kidney and the lodge after removal the chunk of renal parenchyma. Additionally, the visualization and reconstruction was performed on animal porcine model. Moreover, 5 patients (3 women, 2 men) aged from 37 to 68 years (mean 56), diagnosed with kidney tumors in CT scans with a diameter of 3.7-6.9 cm (mean 4.9) were operated in our Department this year, scanning the surface during the treatment with the kidney tumor and kidney tumor after it is removed with a margin of renal tissue. In one case, the lodge of removed tumor was scanned. Dimensions in 3D reconstruction images of laser scans in the study of animal model and the images obtained intraoperatively were compared with the dimensions evaluated during preoperative CT scans, intraoperative measurements. Three-dimensional imaging laser scanner operating field loge resected tumor and the tumor on the kidney of animal models and during NSS treatments for patients with kidney tumors is possible in real time with an accuracy of -2 mm do +9 mm (+/- 3 mm). The duration of data acquisition by laser scanner and obtain three-dimensional image of the operating field takes an average of 13 seconds +/- 2 seconds. Movements associated with breathing and heart rate did not affect on the quality of the reconstruction. The imposition of the scanned surface texture occurs in real time, allowing you to identify renal parenchymal structures such as renal cortex, pyramids, pyelo-calices complex. Imaging control of NSS procedures is possible in animal models and in real time intraoperatively. The comparison of tumor size and the tumor lodge obtained in preoperative CT scans with the measurements during NSS procedure provide the surgeon to assess the extent of macroscopic estimation of the resection. This procedure helps the surgeon in obtaining oncological radicality with saving as much normal tissue kidney as possible. Performance of the imaging methods should be evaluated on a larger group of patients with kidney tumors eligible for NSS treatment.

  9. Ultrasound-guided lumbar puncture in pediatric patients: technical success and safety.

    PubMed

    Pierce, David B; Shivaram, Giri; Koo, Kevin S H; Shaw, Dennis W W; Meyer, Kirby F; Monroe, Eric J

    2018-06-01

    Disadvantages of fluoroscopically guided lumbar puncture include delivery of ionizing radiation and limited resolution of incompletely ossified posterior elements. Ultrasound (US) allows visualization of critical soft tissues and the cerebrospinal fluid (CSF) space without ionizing radiation. To determine the technical success and safety of US-guided lumbar puncture in pediatric patients. A retrospective review identified all patients referred to interventional radiology for lumbar puncture between June 2010 and June 2017. Patients who underwent lumbar puncture with fluoroscopic guidance alone were excluded. For the remaining procedures, technical success and procedural complications were assessed. Two hundred and one image-guided lumbar punctures in 161 patients were included. Eighty patients (43%) had previously failed landmark-based attempts. One hundred ninety-six (97.5%) patients underwent lumbar puncture. Five procedures (2.5%) were not attempted after US assessment, either due to a paucity of CSF or unsafe window for needle placement. Technical success was achieved in 187 (95.4%) of lumbar punctures attempted with US guidance. One hundred seventy-seven (90.3%) were technically successful with US alone (age range: 2 days-15 years, weight range: 1.9-53.1 kg) and an additional 10 (5.1%) were successful with US-guided thecal access and subsequent fluoroscopic confirmation. Three (1.5%) cases were unsuccessful with US guidance but were subsequently successful with fluoroscopic guidance. Of the 80 previously failed landmark-based lumbar punctures, 77 (96.3%) were successful with US guidance alone. There were no reported complications. US guidance is safe and effective for lumbar punctures and has specific advantages over fluoroscopy in pediatric patients.

  10. Image-guided system versus manual marking for toric intraocular lens alignment in cataract surgery.

    PubMed

    Webers, Valentijn S C; Bauer, Noel J C; Visser, Nienke; Berendschot, Tos T J M; van den Biggelaar, Frank J H M; Nuijts, Rudy M M A

    2017-06-01

    To compare the accuracy of toric intraocular lens (IOL) alignment using the Verion Image-Guided System versus a conventional manual ink-marking procedure. University Eye Clinic Maastricht, Maastricht, the Netherlands. Prospective randomized clinical trial. Eyes with regular corneal astigmatism of at least 1.25 diopters (D) that required cataract surgery and toric IOL implantation (Acrysof SN6AT3-T9) were randomly assigned to the image-guided group or the manual-marking group. The primary outcome was the alignment of the toric IOL based on preoperative images and images taken immediately after surgery. Secondary outcome measures were residual astigmatism, uncorrected distance visual acuity (UDVA), and complications. The study enrolled 36 eyes (24 patients). The mean toric IOL misalignment was significantly less in the image-guided group than in the manual group 1 hour (1.3 degrees ± 1.6 [SD] versus 2.8 ± 1.8 degrees; P = .02) and 3 months (1.7 ± 1.5 degrees versus 3.1 ± 2.1 degrees; P < .05) postoperatively. The mean residual refractive cylinder was -0.36 ± 0.32 D and -0.47 ± 0.28 D in the image-guided group and manual group, respectively (P > .05). The mean UDVA was 0.03 ± 0.10 logarithm of minimum angle of resolution (logMAR) and 0.04 ± 0.09 logMAR, respectively (both P > .05). No intraoperative complications occurred during any surgery. The IOL misalignment was significantly less with digital marking than with manual marking; this did not result in a better UDVA or lower residual refractive astigmatism. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. A systematic review of visual image theory, assessment, and use in skin cancer and tanning research.

    PubMed

    McWhirter, Jennifer E; Hoffman-Goetz, Laurie

    2014-01-01

    Visual images increase attention, comprehension, and recall of health information and influence health behaviors. Health communication campaigns on skin cancer and tanning often use visual images, but little is known about how such images are selected or evaluated. A systematic review of peer-reviewed, published literature on skin cancer and tanning was conducted to determine (a) what visual communication theories were used, (b) how visual images were evaluated, and (c) how visual images were used in the research studies. Seven databases were searched (PubMed/MEDLINE, EMBASE, PsycINFO, Sociological Abstracts, Social Sciences Full Text, ERIC, and ABI/INFORM) resulting in 5,330 citations. Of those, 47 met the inclusion criteria. Only one study specifically identified a visual communication theory guiding the research. No standard instruments for assessing visual images were reported. Most studies lacked, to varying degrees, comprehensive image description, image pretesting, full reporting of image source details, adequate explanation of image selection or development, and example images. The results highlight the need for greater theoretical and methodological attention to visual images in health communication research in the future. To this end, the authors propose a working definition of visual health communication.

  12. A Virtual Reality System for PTCD Simulation Using Direct Visuo-Haptic Rendering of Partially Segmented Image Data.

    PubMed

    Fortmeier, Dirk; Mastmeyer, Andre; Schröder, Julian; Handels, Heinz

    2016-01-01

    This study presents a new visuo-haptic virtual reality (VR) training and planning system for percutaneous transhepatic cholangio-drainage (PTCD) based on partially segmented virtual patient models. We only use partially segmented image data instead of a full segmentation and circumvent the necessity of surface or volume mesh models. Haptic interaction with the virtual patient during virtual palpation, ultrasound probing and needle insertion is provided. Furthermore, the VR simulator includes X-ray and ultrasound simulation for image-guided training. The visualization techniques are GPU-accelerated by implementation in Cuda and include real-time volume deformations computed on the grid of the image data. Computation on the image grid enables straightforward integration of the deformed image data into the visualization components. To provide shorter rendering times, the performance of the volume deformation algorithm is improved by a multigrid approach. To evaluate the VR training system, a user evaluation has been performed and deformation algorithms are analyzed in terms of convergence speed with respect to a fully converged solution. The user evaluation shows positive results with increased user confidence after a training session. It is shown that using partially segmented patient data and direct volume rendering is suitable for the simulation of needle insertion procedures such as PTCD.

  13. Towards real-time cardiovascular magnetic resonance guided transarterial CoreValve implantation: in vivo evaluation in swine

    PubMed Central

    2012-01-01

    Background Real-time cardiovascular magnetic resonance (rtCMR) is considered attractive for guiding TAVI. Owing to an unlimited scan plane orientation and an unsurpassed soft-tissue contrast with simultaneous device visualization, rtCMR is presumed to allow safe device navigation and to offer optimal orientation for precise axial positioning. We sought to evaluate the preclinical feasibility of rtCMR-guided transarterial aortic valve implatation (TAVI) using the nitinol-based Medtronic CoreValve bioprosthesis. Methods rtCMR-guided transfemoral (n = 2) and transsubclavian (n = 6) TAVI was performed in 8 swine using the original CoreValve prosthesis and a modified, CMR-compatible delivery catheter without ferromagnetic components. Results rtCMR using TrueFISP sequences provided reliable imaging guidance during TAVI, which was successful in 6 swine. One transfemoral attempt failed due to unsuccessful aortic arch passage and one pericardial tamponade with subsequent death occurred as a result of ventricular perforation by the device tip due to an operating error, this complication being detected without delay by rtCMR. rtCMR allowed for a detailed, simultaneous visualization of the delivery system with the mounted stent-valve and the surrounding anatomy, resulting in improved visualization during navigation through the vasculature, passage of the aortic valve, and during placement and deployment of the stent-valve. Post-interventional success could be confirmed using ECG-triggered time-resolved cine-TrueFISP and flow-sensitive phase-contrast sequences. Intended valve position was confirmed by ex-vivo histology. Conclusions Our study shows that rtCMR-guided TAVI using the commercial CoreValve prosthesis in conjunction with a modified delivery system is feasible in swine, allowing improved procedural guidance including immediate detection of complications and direct functional assessment with reduction of radiation and omission of contrast media. PMID:22453050

  14. Towards real-time cardiovascular magnetic resonance guided transarterial CoreValve implantation: in vivo evaluation in swine.

    PubMed

    Kahlert, Philipp; Parohl, Nina; Albert, Juliane; Schäfer, Lena; Reinhardt, Renate; Kaiser, Gernot M; McDougall, Ian; Decker, Brad; Plicht, Björn; Erbel, Raimund; Eggebrecht, Holger; Ladd, Mark E; Quick, Harald H

    2012-03-27

    Real-time cardiovascular magnetic resonance (rtCMR) is considered attractive for guiding TAVI. Owing to an unlimited scan plane orientation and an unsurpassed soft-tissue contrast with simultaneous device visualization, rtCMR is presumed to allow safe device navigation and to offer optimal orientation for precise axial positioning. We sought to evaluate the preclinical feasibility of rtCMR-guided transarterial aortic valve implatation (TAVI) using the nitinol-based Medtronic CoreValve bioprosthesis. rtCMR-guided transfemoral (n = 2) and transsubclavian (n = 6) TAVI was performed in 8 swine using the original CoreValve prosthesis and a modified, CMR-compatible delivery catheter without ferromagnetic components. rtCMR using TrueFISP sequences provided reliable imaging guidance during TAVI, which was successful in 6 swine. One transfemoral attempt failed due to unsuccessful aortic arch passage and one pericardial tamponade with subsequent death occurred as a result of ventricular perforation by the device tip due to an operating error, this complication being detected without delay by rtCMR. rtCMR allowed for a detailed, simultaneous visualization of the delivery system with the mounted stent-valve and the surrounding anatomy, resulting in improved visualization during navigation through the vasculature, passage of the aortic valve, and during placement and deployment of the stent-valve. Post-interventional success could be confirmed using ECG-triggered time-resolved cine-TrueFISP and flow-sensitive phase-contrast sequences. Intended valve position was confirmed by ex-vivo histology. Our study shows that rtCMR-guided TAVI using the commercial CoreValve prosthesis in conjunction with a modified delivery system is feasible in swine, allowing improved procedural guidance including immediate detection of complications and direct functional assessment with reduction of radiation and omission of contrast media.

  15. Preliminary study of rib articulated model based on dynamic fluoroscopy images

    NASA Astrophysics Data System (ADS)

    Villard, Pierre-Frederic; Escamilla, Pierre; Kerrien, Erwan; Gorges, Sebastien; Trousset, Yves; Berger, Marie-Odile

    2014-03-01

    We present in this paper a preliminary study of rib motion tracking during Interventional Radiology (IR) fluoroscopy guided procedures. It consists in providing a physician with moving rib three-dimensional (3D) models projected in the fluoroscopy plane during a treatment. The strategy is to help to quickly recognize the target and the no-go areas i.e. the tumor and the organs to avoid. The method consists in i) elaborating a kinematic model of each rib from a preoperative computerized tomography (CT) scan, ii) processing the on-line fluoroscopy image and iii) optimizing the parameters of the kinematic law such as the transformed 3D rib projected on the medical image plane fit well with the previously processed image. The results show a visually good rib tracking that has been quantitatively validated by showing a periodic motion as well as a good synchronism between ribs.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borot de Battisti, Maxence, E-mail: M.E.P.Borot@um

    Purpose: The development of MR-guided high dose rate (HDR) brachytherapy is under investigation due to the excellent tumor and organs at risk visualization of MRI. However, MR-based localization of needles (including catheters or tubes) has inherently a low update rate and the required image interpretation can be hampered by signal voids arising from blood vessels or calcifications limiting the precision of the needle guidance and reconstruction. In this paper, a new needle tracking prototype is investigated using fiber Bragg gratings (FBG)-based sensing: this prototype involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensorsmore » each. This stylet can be inserted into brachytherapy needles and allows a fast measurement of the needle deflection. This study aims to assess the potential of FBG-based sensing for real-time needle (including catheter or tube) tracking during MR-guided intervention. Methods: First, the MR compatibility of FBG-based sensing and its accuracy was evaluated. Different known needle deflections were measured using FBG-based sensing during simultaneous MR-imaging. Then, a needle tracking procedure using FBG-based sensing was proposed. This procedure involved a MR-based calibration of the FBG-based system performed prior to the interventional procedure. The needle tracking system was assessed in an experiment with a moving phantom during MR imaging. The FBG-based system was quantified by comparing the gold-standard shapes, the shape manually segmented on MRI and the FBG-based measurements. Results: The evaluation of the MR compatibility of FBG-based sensing and its accuracy shows that the needle deflection could be measured with an accuracy of 0.27 mm on average. Besides, the FBG-based measurements were comparable to the uncertainty of MR-based measurements estimated at half the voxel size in the MR image. Finally, the mean(standard deviation) Euclidean distance between MR- and FBG-based needle position measurements was equal to 0.79 mm(0.37 mm). The update rate and latency of the FBG-based needle position measurement were 100 and 300 ms, respectively. Conclusions: The FBG-based needle tracking procedure proposed in this paper is able to determine the position of the complete needle, under MR-imaging, with better accuracy and precision, higher update rate, and lower latency compared to current MR-based needle localization methods. This system would be eligible for MR-guided brachytherapy, in particular, for an improved needle guidance and reconstruction.« less

  17. Visual servoing in medical robotics: a survey. Part I: endoscopic and direct vision imaging - techniques and applications.

    PubMed

    Azizian, Mahdi; Khoshnam, Mahta; Najmaei, Nima; Patel, Rajni V

    2014-09-01

    Intra-operative imaging is widely used to provide visual feedback to a clinician when he/she performs a procedure. In visual servoing, surgical instruments and parts of tissue/body are tracked by processing the acquired images. This information is then used within a control loop to manoeuvre a robotic manipulator during a procedure. A comprehensive search of electronic databases was completed for the period 2000-2013 to provide a survey of the visual servoing applications in medical robotics. The focus is on medical applications where image-based tracking is used for closed-loop control of a robotic system. Detailed classification and comparative study of various contributions in visual servoing using endoscopic or direct visual images are presented and summarized in tables and diagrams. The main challenges in using visual servoing for medical robotic applications are identified and potential future directions are suggested. 'Supervised automation of medical robotics' is found to be a major trend in this field. Copyright © 2013 John Wiley & Sons, Ltd.

  18. Is Intra-Articular Steroid Injection to the Temporomandibular Joint for Juvenile Idiopathic Arthritis More Effective and Efficient When Performed With Image Guidance?

    PubMed

    Resnick, Cory M; Vakilian, Pouya M; Kaban, Leonard B; Peacock, Zachary S

    2017-04-01

    To compare short-term outcomes and procedure times for intra-articular steroid injection (IASI) to the temporomandibular joint (TMJ) with and without the use of intraoperative image guidance for patients with juvenile idiopathic arthritis (JIA). This is a retrospective study of children with JIA who underwent TMJ IASI at Boston Children's Hospital (Boston, MA). Patients were divided into groups according to IASI technique: 1) "landmark" group if performed by an oral and maxillofacial surgeon using an anatomic landmark technique with no intraoperative image guidance or 2) "image-guided" group if performed by an interventional radiologist using intraoperative ultrasound and computed tomography. Predictor variables included IASI technique (landmark vs image guided), age, gender, JIA subtype, category of medications for arthritis, and presence of family history of autoimmune disease. Outcome variables were changes in patient-reported pain, maximal incisal opening (MIO), synovial enhancement ratio (ER), and total procedure time. Forty-five patients with 71 injected TMJs were included. Twenty-two patients with 36 injected TMJs were in the landmark group and 23 patients with 35 injected joints were in the image-guided group. There were no relevant differences in age, gender, family history of rheumatologic disease, or disease subtype between groups. There were no differences in resolution of pain (P = 1.00), increase in MIO (P = .975), or decrease in ER (P = .492) between groups, but procedure times averaged 49 minutes longer for the image-guided group (P < .008). There were no statistical differences in short-term outcomes, but procedure times were longer for the image-guided group. Although specific indications for the use of image guidance might exist, routine use of this procedure cannot be justified. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  19. SimITK: visual programming of the ITK image-processing library within Simulink.

    PubMed

    Dickinson, Andrew W L; Abolmaesumi, Purang; Gobbi, David G; Mousavi, Parvin

    2014-04-01

    The Insight Segmentation and Registration Toolkit (ITK) is a software library used for image analysis, visualization, and image-guided surgery applications. ITK is a collection of C++ classes that poses the challenge of a steep learning curve should the user not have appropriate C++ programming experience. To remove the programming complexities and facilitate rapid prototyping, an implementation of ITK within a higher-level visual programming environment is presented: SimITK. ITK functionalities are automatically wrapped into "blocks" within Simulink, the visual programming environment of MATLAB, where these blocks can be connected to form workflows: visual schematics that closely represent the structure of a C++ program. The heavily templated C++ nature of ITK does not facilitate direct interaction between Simulink and ITK; an intermediary is required to convert respective data types and allow intercommunication. As such, a SimITK "Virtual Block" has been developed that serves as a wrapper around an ITK class which is capable of resolving the ITK data types to native Simulink data types. Part of the challenge surrounding this implementation involves automatically capturing and storing the pertinent class information that need to be refined from an initial state prior to being reflected within the final block representation. The primary result from the SimITK wrapping procedure is multiple Simulink block libraries. From these libraries, blocks are selected and interconnected to demonstrate two examples: a 3D segmentation workflow and a 3D multimodal registration workflow. Compared to their pure-code equivalents, the workflows highlight ITK usability through an alternative visual interpretation of the code that abstracts away potentially confusing technicalities.

  20. Photon-counting hexagonal pixel array CdTe detector: Spatial resolution characteristics for image-guided interventional applications

    PubMed Central

    Shrestha, Suman; Karellas, Andrew; Shi, Linxi; Gounis, Matthew J.; Bellazzini, Ronaldo; Spandre, Gloria; Brez, Alessandro; Minuti, Massimo

    2016-01-01

    Purpose: High-resolution, photon-counting, energy-resolved detector with fast-framing capability can facilitate simultaneous acquisition of precontrast and postcontrast images for subtraction angiography without pixel registration artifacts and can facilitate high-resolution real-time imaging during image-guided interventions. Hence, this study was conducted to determine the spatial resolution characteristics of a hexagonal pixel array photon-counting cadmium telluride (CdTe) detector. Methods: A 650 μm thick CdTe Schottky photon-counting detector capable of concurrently acquiring up to two energy-windowed images was operated in a single energy-window mode to include photons of 10 keV or higher. The detector had hexagonal pixels with apothem of 30 μm resulting in pixel pitch of 60 and 51.96 μm along the two orthogonal directions. The detector was characterized at IEC-RQA5 spectral conditions. Linear response of the detector was determined over the air kerma rate relevant to image-guided interventional procedures ranging from 1.3 nGy/frame to 91.4 μGy/frame. Presampled modulation transfer was determined using a tungsten edge test device. The edge-spread function and the finely sampled line spread function accounted for hexagonal sampling, from which the presampled modulation transfer function (MTF) was determined. Since detectors with hexagonal pixels require resampling to square pixels for distortion-free display, the optimal square pixel size was determined by minimizing the root-mean-squared-error of the aperture functions for the square and hexagonal pixels up to the Nyquist limit. Results: At Nyquist frequencies of 8.33 and 9.62 cycles/mm along the apothem and orthogonal to the apothem directions, the modulation factors were 0.397 and 0.228, respectively. For the corresponding axis, the limiting resolution defined as 10% MTF occurred at 13.3 and 12 cycles/mm, respectively. Evaluation of the aperture functions yielded an optimal square pixel size of 54 μm. After resampling to 54 μm square pixels using trilinear interpolation, the presampled MTF at Nyquist frequency of 9.26 cycles/mm was 0.29 and 0.24 along the orthogonal directions and the limiting resolution (10% MTF) occurred at approximately 12 cycles/mm. Visual analysis of a bar pattern image showed the ability to resolve close to 12 line-pairs/mm and qualitative evaluation of a neurovascular nitinol-stent showed the ability to visualize its struts at clinically relevant conditions. Conclusions: Hexagonal pixel array photon-counting CdTe detector provides high spatial resolution in single-photon counting mode. After resampling to optimal square pixel size for distortion-free display, the spatial resolution is preserved. The dual-energy capabilities of the detector could allow for artifact-free subtraction angiography and basis material decomposition. The proposed high-resolution photon-counting detector with energy-resolving capability can be of importance for several image-guided interventional procedures as well as for pediatric applications. PMID:27147324

  1. Photon-counting hexagonal pixel array CdTe detector: Spatial resolution characteristics for image-guided interventional applications.

    PubMed

    Vedantham, Srinivasan; Shrestha, Suman; Karellas, Andrew; Shi, Linxi; Gounis, Matthew J; Bellazzini, Ronaldo; Spandre, Gloria; Brez, Alessandro; Minuti, Massimo

    2016-05-01

    High-resolution, photon-counting, energy-resolved detector with fast-framing capability can facilitate simultaneous acquisition of precontrast and postcontrast images for subtraction angiography without pixel registration artifacts and can facilitate high-resolution real-time imaging during image-guided interventions. Hence, this study was conducted to determine the spatial resolution characteristics of a hexagonal pixel array photon-counting cadmium telluride (CdTe) detector. A 650 μm thick CdTe Schottky photon-counting detector capable of concurrently acquiring up to two energy-windowed images was operated in a single energy-window mode to include photons of 10 keV or higher. The detector had hexagonal pixels with apothem of 30 μm resulting in pixel pitch of 60 and 51.96 μm along the two orthogonal directions. The detector was characterized at IEC-RQA5 spectral conditions. Linear response of the detector was determined over the air kerma rate relevant to image-guided interventional procedures ranging from 1.3 nGy/frame to 91.4 μGy/frame. Presampled modulation transfer was determined using a tungsten edge test device. The edge-spread function and the finely sampled line spread function accounted for hexagonal sampling, from which the presampled modulation transfer function (MTF) was determined. Since detectors with hexagonal pixels require resampling to square pixels for distortion-free display, the optimal square pixel size was determined by minimizing the root-mean-squared-error of the aperture functions for the square and hexagonal pixels up to the Nyquist limit. At Nyquist frequencies of 8.33 and 9.62 cycles/mm along the apothem and orthogonal to the apothem directions, the modulation factors were 0.397 and 0.228, respectively. For the corresponding axis, the limiting resolution defined as 10% MTF occurred at 13.3 and 12 cycles/mm, respectively. Evaluation of the aperture functions yielded an optimal square pixel size of 54 μm. After resampling to 54 μm square pixels using trilinear interpolation, the presampled MTF at Nyquist frequency of 9.26 cycles/mm was 0.29 and 0.24 along the orthogonal directions and the limiting resolution (10% MTF) occurred at approximately 12 cycles/mm. Visual analysis of a bar pattern image showed the ability to resolve close to 12 line-pairs/mm and qualitative evaluation of a neurovascular nitinol-stent showed the ability to visualize its struts at clinically relevant conditions. Hexagonal pixel array photon-counting CdTe detector provides high spatial resolution in single-photon counting mode. After resampling to optimal square pixel size for distortion-free display, the spatial resolution is preserved. The dual-energy capabilities of the detector could allow for artifact-free subtraction angiography and basis material decomposition. The proposed high-resolution photon-counting detector with energy-resolving capability can be of importance for several image-guided interventional procedures as well as for pediatric applications.

  2. Adjunctive intracardiac echocardiography imaging from the left ventricle to guide percutaneous mitral valve repair with the MitraClip in patients with failed prior surgical rings.

    PubMed

    Saji, Mike; Rossi, Ann M; Ailawadi, Gorav; Dent, John; Ragosta, Michael; Lim, D Scott

    2016-02-01

    We evaluated intracardiac echocardiography (ICE) for adjunctively guiding the MitraClip procedure in patients with prior surgical rings. Transesophageal echocardiography (TEE) is the standard imaging modality used to guide the MitraClip procedure (Abbott Vascular, CA). However, in patients with post-surgical anatomy, clear imaging of the mitral valve leaflets may be complex because of shadowing from the surgical ring. In these patients, TEE may be suboptimal for guiding the procedure, even using three-dimensional imaging. This retrospective analysis included data from 121 consecutive patients with mitral regurgitation who underwent MitraClip procedures at the University of Virginia. ICE was used adjunctively when there was difficulty with TEE, particularly for assessing the insertion of the posterior leaflet into the MitraClip's arms. The ICE catheter was introduced transarterially into the left ventricle and flexed to obtain the short-axis view. Six patients had prior surgical rings, and in five, we used adjunctive ICE. The etiology of the mitral regurgitation was prolapse of the posterior leaflet in one patient and restriction of the posterior leaflet due to ischemic tethering in the remainder. All images were obtained from the left ventricle, and were adequate for assessing posterior leaflet insertion and the perpendicularity of the MitraClip arms. The procedural success rate was 80%. There was no adverse event related to the ICE procedure. Mitral valve repair with the MitraClip system assisted by ICE is feasible in patients with prior surgical rings, achieving an excellent risk profile and satisfactory procedural success. © 2015 Wiley Periodicals, Inc.

  3. The Role of Clarity and Blur in Guiding Visual Attention in Photographs

    ERIC Educational Resources Information Center

    Enns, James T.; MacDonald, Sarah C.

    2013-01-01

    Visual artists and photographers believe that a viewer's gaze can be guided by selective use of image clarity and blur, but there is little systematic research. In this study, participants performed several eye-tracking tasks with the same naturalistic photographs, including recognition memory for the entire photo, as well as recognition memory…

  4. Projection-slice theorem based 2D-3D registration

    NASA Astrophysics Data System (ADS)

    van der Bom, M. J.; Pluim, J. P. W.; Homan, R.; Timmer, J.; Bartels, L. W.

    2007-03-01

    In X-ray guided procedures, the surgeon or interventionalist is dependent on his or her knowledge of the patient's specific anatomy and the projection images acquired during the procedure by a rotational X-ray source. Unfortunately, these X-ray projections fail to give information on the patient's anatomy in the dimension along the projection axis. It would be very profitable to provide the surgeon or interventionalist with a 3D insight of the patient's anatomy that is directly linked to the X-ray images acquired during the procedure. In this paper we present a new robust 2D-3D registration method based on the Projection-Slice Theorem. This theorem gives us a relation between the pre-operative 3D data set and the interventional projection images. Registration is performed by minimizing a translation invariant similarity measure that is applied to the Fourier transforms of the images. The method was tested by performing multiple exhaustive searches on phantom data of the Circle of Willis and on a post-mortem human skull. Validation was performed visually by comparing the test projections to the ones that corresponded to the minimal value of the similarity measure. The Projection-Slice Theorem Based method was shown to be very effective and robust, and provides capture ranges up to 62 degrees. Experiments have shown that the method is capable of retrieving similar results when translations are applied to the projection images.

  5. Considering Visual Text Complexity: A Guide for Teachers

    ERIC Educational Resources Information Center

    Cappello, Marva

    2017-01-01

    Twenty-first century literacy requires students to analyze and create images for communication across and within academic disciplines. Thus, literacy teachers are now responsible for supporting students as they engage with visual texts. We must carefully and intentionally choose images for teaching practice and consider the reader, instructional…

  6. Real-time simulation and visualization of volumetric brain deformation for image-guided neurosurgery

    NASA Astrophysics Data System (ADS)

    Ferrant, Matthieu; Nabavi, Arya; Macq, Benoit M. M.; Kikinis, Ron; Warfield, Simon K.

    2001-05-01

    During neurosurgery, the challenge for the neurosurgeon is to remove as much as possible of a tumor without destroying healthy tissue. This can be difficult because healthy and diseased tissue can have the same visual appearance. To this aim, and because the surgeon cannot see underneath the brain surface, image-guided neurosurgery systems are being increasingly used. However, during surgery, deformation of the brain occurs (due to brain shift and tumor resection), therefore causing errors in the surgical planning with respect to preoperative imaging. In our previous work, we developed software for capturing the deformation of the brain during neurosurgery. The software also allows preoperative data to be updated according to the intraoperative imaging so as to reflect the shape changes of the brain during surgery. Our goal in this paper was to rapidly visualize and characterize this deformation over the course of surgery with appropriate tools. Therefore, we developed tools allowing the doctor to visualize (in 2D and 3D) deformations, as well as the stress tensors characterizing the deformation along with the updated preoperative and intraoperative imaging during the course of surgery. Such tools significantly add to the value of intraoperative imaging and hence could improve surgical outcomes.

  7. Endoscopic surgery and telemedicine in microgravity: developing contingency procedures for exploratory class spaceflight.

    PubMed

    Jones, J A; Johnston, S; Campbell, M; Miles, B; Billica, R

    1999-05-01

    The risk of a urinary calculus during an extended duration mission into the reduced gravity environment of space is significant. For medical operations to develop a comprehensive strategy for the spaceflight stone risk, both preventive countermeasures and contingency management (CM) plans must be included. A feasibility study was conducted to demonstrate the potential CM technique of endoscopic ureteral stenting with ultrasound guidance for the possible in-flight urinary calculus contingency. The procedure employed the International Space Station/Human Research Facility ultrasound unit for guide wire and stent localization, a flexible cystoscope for visual guidance, and banded, biocompatible soft ureteral stents to successfully stent porcine ureters bilaterally in zero gravity (0g). The study demonstrated that downlinked endoscopic surgical and ultrasound images obtained in 0g are comparable in quality to 1g images, and therefore are useful for diagnostic clinical utility via telemedicine transmission. In order to be successful, surgical procedures in 0g require excellent positional stability of the operating surgeon, assistant, and patient, relative to one another. The technological development of medical procedures for long-duration spaceflight contingencies may lead to improved terrestrial patient care methodology and subsequently reduced morbidity.

  8. Endoscopic surgery and telemedicine in microgravity: developing contingency procedures for exploratory class spaceflight

    NASA Technical Reports Server (NTRS)

    Jones, J. A.; Johnston, S.; Campbell, M.; Miles, B.; Billica, R.

    1999-01-01

    OBJECTIVES: The risk of a urinary calculus during an extended duration mission into the reduced gravity environment of space is significant. For medical operations to develop a comprehensive strategy for the spaceflight stone risk, both preventive countermeasures and contingency management (CM) plans must be included. METHODS: A feasibility study was conducted to demonstrate the potential CM technique of endoscopic ureteral stenting with ultrasound guidance for the possible in-flight urinary calculus contingency. The procedure employed the International Space Station/Human Research Facility ultrasound unit for guide wire and stent localization, a flexible cystoscope for visual guidance, and banded, biocompatible soft ureteral stents to successfully stent porcine ureters bilaterally in zero gravity (0g). RESULTS: The study demonstrated that downlinked endoscopic surgical and ultrasound images obtained in 0g are comparable in quality to 1g images, and therefore are useful for diagnostic clinical utility via telemedicine transmission. CONCLUSIONS: In order to be successful, surgical procedures in 0g require excellent positional stability of the operating surgeon, assistant, and patient, relative to one another. The technological development of medical procedures for long-duration spaceflight contingencies may lead to improved terrestrial patient care methodology and subsequently reduced morbidity.

  9. Augmented Reality Visualization with Use of Image Overlay Technology for MR Imaging–guided Interventions: Assessment of Performance in Cadaveric Shoulder and Hip Arthrography at 1.5 T

    PubMed Central

    Fritz, Jan; U-Thainual, Paweena; Ungi, Tamas; Flammang, Aaron J.; Fichtinger, Gabor; Iordachita, Iulian I.

    2012-01-01

    Purpose: To prospectively assess overlay technology in providing accurate and efficient targeting for magnetic resonance (MR) imaging–guided shoulder and hip joint arthrography. Materials and Methods: A prototype augmented reality image overlay system was used in conjunction with a clinical 1.5-T MR imager. A total of 24 shoulder joint and 24 hip joint injections were planned in 12 human cadavers. Two operators (A and B) participated, each performing procedures on different cadavers using image overlay guidance. MR imaging was used to confirm needle positions, monitor injections, and perform MR arthrography. Accuracy was assessed according to the rate of needle adjustment, target error, and whether the injection was intraarticular. Efficiency was assessed according to arthrography procedural time. Operator differences were assessed with comparison of accuracy and procedure times between the operators. Mann-Whitney U test and Fisher exact test were used to assess group differences. Results: Forty-five arthrography procedures (23 shoulders, 22 hips) were performed. Three joints had prostheses and were excluded. Operator A performed 12 shoulder and 12 hip injections. Operator B performed 11 shoulder and 10 hip injections. Needle adjustment rate was 13% (six of 45; one for operator A and five for operator B). Target error was 3.1 mm ± 1.2 (standard deviation) (operator A, 2.9 mm ± 1.4; operator B, 3.5 mm ± 0.9). Intraarticular injection rate was 100% (45 of 45). The average arthrography time was 14 minutes (range, 6–27 minutes; 12 minutes [range, 6–25 minutes] for operator A and 16 minutes [range, 6–27 min] for operator B). Operator differences were not significant with regard to needle adjustment rate (P = .08), target error (P = .07), intraarticular injection rate (P > .99), and arthrography time (P = .22). Conclusion: Image overlay technology provides accurate and efficient MR guidance for successful shoulder and hip arthrography in human cadavers. © RSNA, 2012 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12112640/-/DC1 PMID:22843764

  10. Procedures for precap visual inspection

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Screening procedures for the final precap visual inspection of microcircuits used in electronic system components are described as an aid in training personnel unfamiliar with microcircuits. Processing techniques used in industry for the manufacture of monolithic and hybrid components are presented and imperfections that may be encountered during this inspection are discussed. Problem areas such as scratches, voids, adhesions, and wire bonding are illustrated by photomicrographs. This guide can serve as an effective tool in training personnel to perform precap visual inspections efficiently and reliably.

  11. MR image reconstruction via guided filter.

    PubMed

    Huang, Heyan; Yang, Hang; Wang, Kang

    2018-04-01

    Magnetic resonance imaging (MRI) reconstruction from the smallest possible set of Fourier samples has been a difficult problem in medical imaging field. In our paper, we present a new approach based on a guided filter for efficient MRI recovery algorithm. The guided filter is an edge-preserving smoothing operator and has better behaviors near edges than the bilateral filter. Our reconstruction method is consist of two steps. First, we propose two cost functions which could be computed efficiently and thus obtain two different images. Second, the guided filter is used with these two obtained images for efficient edge-preserving filtering, and one image is used as the guidance image, the other one is used as a filtered image in the guided filter. In our reconstruction algorithm, we can obtain more details by introducing guided filter. We compare our reconstruction algorithm with some competitive MRI reconstruction techniques in terms of PSNR and visual quality. Simulation results are given to show the performance of our new method.

  12. Facial recognition using multisensor images based on localized kernel eigen spaces.

    PubMed

    Gundimada, Satyanadh; Asari, Vijayan K

    2009-06-01

    A feature selection technique along with an information fusion procedure for improving the recognition accuracy of a visual and thermal image-based facial recognition system is presented in this paper. A novel modular kernel eigenspaces approach is developed and implemented on the phase congruency feature maps extracted from the visual and thermal images individually. Smaller sub-regions from a predefined neighborhood within the phase congruency images of the training samples are merged to obtain a large set of features. These features are then projected into higher dimensional spaces using kernel methods. The proposed localized nonlinear feature selection procedure helps to overcome the bottlenecks of illumination variations, partial occlusions, expression variations and variations due to temperature changes that affect the visual and thermal face recognition techniques. AR and Equinox databases are used for experimentation and evaluation of the proposed technique. The proposed feature selection procedure has greatly improved the recognition accuracy for both the visual and thermal images when compared to conventional techniques. Also, a decision level fusion methodology is presented which along with the feature selection procedure has outperformed various other face recognition techniques in terms of recognition accuracy.

  13. A New Era of Image Guidance with Magnetic Resonance-guided Radiation Therapy for Abdominal and Thoracic Malignancies

    PubMed Central

    Paliwal, Bhudatt; Hill, Patrick; Bayouth, John E; Geurts, Mark W; Baschnagel, Andrew M; Bradley, Kristin A; Harari, Paul M; Rosenberg, Stephen; Brower, Jeffrey V; Wojcieszynski, Andrzej P; Hullett, Craig; Bayliss, R A; Labby, Zacariah E; Bassetti, Michael F

    2018-01-01

    Magnetic resonance-guided radiation therapy (MRgRT) offers advantages for image guidance for radiotherapy treatments as compared to conventional computed tomography (CT)-based modalities. The superior soft tissue contrast of magnetic resonance (MR) enables an improved visualization of the gross tumor and adjacent normal tissues in the treatment of abdominal and thoracic malignancies. Online adaptive capabilities, coupled with advanced motion management of real-time tracking of the tumor, directly allow for high-precision inter-/intrafraction localization. The primary aim of this case series is to describe MR-based interventions for localizing targets not well-visualized with conventional image-guided technologies. The abdominal and thoracic sites of the lung, kidney, liver, and gastric targets are described to illustrate the technological advancement of MR-guidance in radiotherapy. PMID:29872602

  14. 32 CFR 813.5 - Shipping or transmitting visual information documentation images.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... documentation images. 813.5 Section 813.5 National Defense Department of Defense (Continued) DEPARTMENT OF THE... visual information documentation images. (a) COMCAM images. Send COMCAM images to the DoD Joint Combat... the approval procedures that on-scene and theater commanders set. (b) Other non-COMCAM images. After...

  15. 32 CFR 813.5 - Shipping or transmitting visual information documentation images.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... documentation images. 813.5 Section 813.5 National Defense Department of Defense (Continued) DEPARTMENT OF THE... visual information documentation images. (a) COMCAM images. Send COMCAM images to the DoD Joint Combat... the approval procedures that on-scene and theater commanders set. (b) Other non-COMCAM images. After...

  16. 32 CFR 813.5 - Shipping or transmitting visual information documentation images.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... documentation images. 813.5 Section 813.5 National Defense Department of Defense (Continued) DEPARTMENT OF THE... visual information documentation images. (a) COMCAM images. Send COMCAM images to the DoD Joint Combat... the approval procedures that on-scene and theater commanders set. (b) Other non-COMCAM images. After...

  17. 32 CFR 813.5 - Shipping or transmitting visual information documentation images.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... documentation images. 813.5 Section 813.5 National Defense Department of Defense (Continued) DEPARTMENT OF THE... visual information documentation images. (a) COMCAM images. Send COMCAM images to the DoD Joint Combat... the approval procedures that on-scene and theater commanders set. (b) Other non-COMCAM images. After...

  18. 32 CFR 813.5 - Shipping or transmitting visual information documentation images.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... documentation images. 813.5 Section 813.5 National Defense Department of Defense (Continued) DEPARTMENT OF THE... visual information documentation images. (a) COMCAM images. Send COMCAM images to the DoD Joint Combat... the approval procedures that on-scene and theater commanders set. (b) Other non-COMCAM images. After...

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ryan, E. Ronan, E-mail: ronan@ronanryan.com; Thornton, Raymond; Sofocleous, Constantinos T.

    PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0-0.13) mSv for the primary operator, 0.01 (range 0-0.05) mSv for the nurse anesthetist, and 0.02 (range 0-0.05) mSv for the radiology technologist. The median extremitymore » dose equivalent for the operator was 0.05 (range 0-0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient.« less

  20. "Visual Learning Is the Best Learning--It Lets You Be Creative while Learning": Exploring Ways to Begin Guided Writing in Second Language Learning through the Use of Comics

    ERIC Educational Resources Information Center

    Rossetto, Marietta; Chiera-Macchia, Antonella

    2011-01-01

    This study investigated the use of comics (Cary, 2004) in a guided writing experience in secondary school Italian language learning. The main focus of the peer group interaction task included the exploration of visual sequencing and visual integration (Bailey, O'Grady-Jones, & McGown, 1995) using image and text to create a comic strip narrative in…

  1. Navigated MRI-guided liver biopsies in a closed-bore scanner: experience in 52 patients.

    PubMed

    Moche, Michael; Heinig, Susann; Garnov, Nikita; Fuchs, Jochen; Petersen, Tim-Ole; Seider, Daniel; Brandmaier, Philipp; Kahn, Thomas; Busse, Harald

    2016-08-01

    To evaluate clinical effectiveness and diagnostic efficiency of a navigation device for MR-guided biopsies of focal liver lesions in a closed-bore scanner. In 52 patients, 55 biopsies were performed. An add-on MR navigation system with optical instrument tracking was used for image guidance and biopsy device insertion outside the bore. Fast control imaging allowed visualization of the true needle position at any time. The biopsy workflow and procedure duration were recorded. Histological analysis and clinical course/outcome were used to calculate sensitivity, specificity and diagnostic accuracy. Fifty-four of 55 liver biopsies were performed successfully with the system. No major and four minor complications occurred. Mean tumour size was 23 ± 14 mm and the skin-to-target length ranged from 22 to 177 mm. In 39 cases, access path was double oblique. Sensitivity, specificity and diagnostic accuracy were 88 %, 100 % and 92 %, respectively. The mean procedure time was 51 ± 12 min, whereas the puncture itself lasted 16 ± 6 min. On average, four control scans were taken. Using this navigation device, biopsies of poorly visible and difficult accessible liver lesions could be performed safely and reliably in a closed-bore MRI scanner. The system can be easily implemented in clinical routine workflow. • Targeted liver biopsies could be reliably performed in a closed-bore MRI. • The navigation system allows for image guidance outside of the scanner bore. • Assisted MRI-guided biopsies are helpful for focal lesions with a difficult access. • Successful integration of the method in clinical workflow was shown. • Subsequent system installation in an existing MRI environment is feasible.

  2. Microendoscopic stereotactic-guided percutaneous radiofrequency trigeminal nucleotractotomy.

    PubMed

    Teixeira, Manoel Jacobsen; de Almeida, Fabrício Freitas; de Oliveira, Ywzhe Sifuentes Almeida; Fonoff, Erich Talamoni

    2012-02-01

    Over the past few decades, various authors have performed open or stereotactic trigeminal nucleotractotomy for the treatment of neuropathic facial pain resistant to medical treatment. Stereotactic procedures can be performed percutaneously under local anesthesia, allowing intraoperative neurological examination as a method for target refinement. However, blind percutaneous procedures in the region of the atlantooccipital transition carry a considerably high risk of vascular injuries that may bring prohibitive neurological deficit or even death. To avoid such complications, the authors present the first clinical use of microendoscopy to assist percutaneous radiofrequency trigeminal nucleotractotomy. The aim of this article is to demonstrate intradural microendoscopic visualization of the medulla oblongata through an atlantooccipital percutaneous approach. The authors present a case of severe postherpetic facial neuralgia in a patient who underwent the procedure and had satisfactory results. Stereotactic computational image planning for targeting the spinal trigeminal tract and nucleus in the posterolateral medulla was performed, allowing for an accurate percutaneous approach. Immediately before radiofrequency electrode insertion, a fine endoscope was introduced to visualize the structures in the cisterna magna. Microendoscopic visualization offered clear identification of the pial surface of the medulla oblongata and its blood vessels, the arachnoid membrane, cranial nerve rootlets and their entry zone, and larger vessels such as the vertebral arteries and the branches of the posterior inferior cerebellar artery. The initial application of this technique suggests that percutaneous microendoscopy may be useful for particular manipulation of the medulla oblongata, increasing the safety of the procedure and likely improving its effectiveness.

  3. Visual servoing of a laser ablation based cochleostomy

    NASA Astrophysics Data System (ADS)

    Kahrs, Lüder A.; Raczkowsky, Jörg; Werner, Martin; Knapp, Felix B.; Mehrwald, Markus; Hering, Peter; Schipper, Jörg; Klenzner, Thomas; Wörn, Heinz

    2008-03-01

    The aim of this study is a defined, visually based and camera controlled bone removal by a navigated CO II laser on the promontory of the inner ear. A precise and minimally traumatic opening procedure of the cochlea for the implantation of a cochlear implant electrode (so-called cochleostomy) is intended. Harming the membrane linings of the inner ear can result in damage of remaining organ functions (e.g. complete deafness or vertigo). A precise tissue removal by a laser-based bone ablation system is investigated. Inside the borehole the pulsed laser beam is guided automatically over the bone by using a two mirror galvanometric scanner. The ablation process is controlled by visual servoing. For the detection of the boundary layers of the inner ear the ablation area is monitored by a color camera. The acquired pictures are analyzed by image processing. The results of this analysis are used to control the process of laser ablation. This publication describes the complete system including image processing algorithms and the concept for the resulting distribution of single laser pulses. The system has been tested on human cochleae in ex-vivo studies. Further developments could lead to safe intraoperative openings of the cochlea by a robot based surgical laser instrument.

  4. Efficacy of a novel IGS system in atrial septal defect repair

    NASA Astrophysics Data System (ADS)

    Mefleh, Fuad N.; Baker, G. Hamilton; Kwartowitz, David M.

    2013-03-01

    Congenital heart disease occurs in 107.6 out of 10,000 live births, with Atrial Septal Defects (ASD) accounting for 10% of these conditions. Historically, ASDs were treated with open heart surgery using cardiopulmonary bypass, allowing a patch to be sewn over the defect. In 1976, King et al. demonstrated use of a transcatheter occlusion procedure, thus reducing the invasiveness of ASD repair. Localization during these catheter based procedures traditionally has relied on bi-plane fluoroscopy; more recently trans-esophageal echocardiography (TEE) and intra-cardiac echocardiography (ICE) have been used to navigate these procedures. Although there is a high success rate using the transcatheter occlusion procedure, fluoroscopy poses radiation dose risk to both patient and clinician. The impact of this dose to the patients is important as many of those undergoing this procedure are children, who have an increased risk associated with radiation exposure. Their longer life expectancy than adults provides a larger window of opportunity for expressing the damaging effects of ionizing radiation. In addition, epidemiologic studies of exposed populations have demonstrated that children are considerably more sensitive to the carcinogenic effects radiation. Image-guided surgery (IGS) uses pre-operative and intra-operative images to guide surgery or an interventional procedure. Central to every IGS system is a software application capable of processing and displaying patient images, registration between multiple coordinate systems, and interfacing with a tool tracking system. We have developed a novel image-guided surgery framework called Kit for Navigation by Image Focused Exploration (KNIFE). In this work we assess the efficacy of this image-guided navigation system for ASD repair using a series of mock clinical experiments designed to simulate ASD repair device deployment.

  5. Implementation of an oblique-sectioning visualization tool for line-of-sight stereotactic neurosurgical navigation using the AVW toolkit

    NASA Astrophysics Data System (ADS)

    Bates, Lisa M.; Hanson, Dennis P.; Kall, Bruce A.; Meyer, Frederic B.; Robb, Richard A.

    1998-06-01

    An important clinical application of biomedical imaging and visualization techniques is provision of image guided neurosurgical planning and navigation techniques using interactive computer display systems in the operating room. Current systems provide interactive display of orthogonal images and 3D surface or volume renderings integrated with and guided by the location of a surgical probe. However, structures in the 'line-of-sight' path which lead to the surgical target cannot be directly visualized, presenting difficulty in obtaining full understanding of the 3D volumetric anatomic relationships necessary for effective neurosurgical navigation below the cortical surface. Complex vascular relationships and histologic boundaries like those found in artereovenous malformations (AVM's) also contribute to the difficulty in determining optimal approaches prior to actual surgical intervention. These difficulties demonstrate the need for interactive oblique imaging methods to provide 'line-of-sight' visualization. Capabilities for 'line-of- sight' interactive oblique sectioning are present in several current neurosurgical navigation systems. However, our implementation is novel, in that it utilizes a completely independent software toolkit, AVW (A Visualization Workshop) developed at the Mayo Biomedical Imaging Resource, integrated with a current neurosurgical navigation system, the COMPASS stereotactic system at Mayo Foundation. The toolkit is a comprehensive, C-callable imaging toolkit containing over 500 optimized imaging functions and structures. The powerful functionality and versatility of the AVW imaging toolkit provided facile integration and implementation of desired interactive oblique sectioning using a finite set of functions. The implementation of the AVW-based code resulted in higher-level functions for complete 'line-of-sight' visualization.

  6. Recent Advances in Image Assisted Neurosurgical Procedures: Improved Navigational Accuracy and Patient Safety

    ScienceCinema

    Olivi, Alessandro, M.D.

    2017-12-09

    Neurosurgical procedures require precise planning and intraoperative support. Recent advances in image guided technology have provided neurosurgeons with improved navigational support for more effective and safer procedures. A number of exemplary cases will be presented.

  7. New and emerging patient-centered CT imaging and image-guided treatment paradigms for maxillofacial trauma.

    PubMed

    Dreizin, David; Nam, Arthur J; Hirsch, Jeffrey; Bernstein, Mark P

    2018-06-20

    This article reviews the conceptual framework, available evidence, and practical considerations pertaining to nascent and emerging advances in patient-centered CT-imaging and CT-guided surgery for maxillofacial trauma. These include cinematic rendering-a novel method for advanced 3D visualization, incorporation of quantitative CT imaging into the assessment of orbital fractures, low-dose CT imaging protocols made possible with contemporary scanners and reconstruction techniques, the rapidly growing use of cone-beam CT, virtual fracture reduction with design software for surgical pre-planning, the use of 3D printing for fabricating models and implants, and new avenues in CT-guided computer-aided surgery.

  8. Visual Pattern Analysis in Histopathology Images Using Bag of Features

    NASA Astrophysics Data System (ADS)

    Cruz-Roa, Angel; Caicedo, Juan C.; González, Fabio A.

    This paper presents a framework to analyse visual patterns in a collection of medical images in a two stage procedure. First, a set of representative visual patterns from the image collection is obtained by constructing a visual-word dictionary under a bag-of-features approach. Second, an analysis of the relationships between visual patterns and semantic concepts in the image collection is performed. The most important visual patterns for each semantic concept are identified using correlation analysis. A matrix visualization of the structure and organization of the image collection is generated using a cluster analysis. The experimental evaluation was conducted on a histopathology image collection and results showed clear relationships between visual patterns and semantic concepts, that in addition, are of easy interpretation and understanding.

  9. Image guided neuroendoscopy for third ventriculostomy.

    PubMed

    Broggi, G; Dones, I; Ferroli, P; Franzini, A; Servello, D; Duca, S

    2000-01-01

    Third ventriculostomy has become an increasing popular procedure for the treatment of hydrocephalus of different aetiologies. Between october 1997 and october 1998, 17 patients (12 females, 5 males; 12-82 year-old; mean age 43) underwent image-assisted endoscopic third ventriculostomy for hydrocephalus at the Istituto Nazionale Neurologico "C.Besta" of Milano. There was no mortality and no long term morbidity. Neuronavigation has been found useful in selecting the safest trajectory to the target avoiding any traction on the foramen of Monro related structures and allowing the necessary mobility for fine adjustments under visual and "tactile" control when choosing the safest point to perform the stoma. According to our experience neuro-endoscopy and neuronavigation seems to be complementary in reaching easy, safe and successful results in the treatment of hydrocephalus of different origins.

  10. Magnetic Resonance Imaging-Guided Osseous Biopsy in Children With Chronic Recurrent Multifocal Osteomyelitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fritz, Jan, E-mail: jfritz9@jhmi.edu; Tzaribachev, Nikolay; Thomas, Christoph

    2012-02-15

    Purpose: To report the safety and diagnostic performance of magnetic resonance (MRI)-guided core biopsy of osseous lesions in children with chronic recurrent multifocal osteomyelitis (CRMO) that were visible on MRI but were occult on radiography and computed tomography (CT). Materials and Methods: A retrospective analysis of MRI-guided osseous biopsy performed in seven children (four girls and three boys; mean age 13 years (range 11 to 14) with CRMO was performed. Indication for using MRI guidance was visibility of lesions by MRI only. MRI-guided procedures were performed with 0.2-Tesla (Magnetom Concerto; Siemens, Erlangen, Germany; n = 5) or 1.5-T (Magnetom Espree;more » Siemens; n = 2) open MRI systems. Core needle biopsy was obtained using an MRI-compatible 4-mm drill system. Conscious sedation or general anesthesia was used. Parameters evaluated were lesion visibility, technical success, procedure time, complications and microbiology, cytology, and histopathology findings. Results: Seven of seven (100%) targeted lesions were successfully visualized and sampled. All obtained specimens were sufficient for histopathological analysis. Length of time of the procedures was 77 min (range 64 to 107). No complications occurred. Histopathology showed no evidence of malignancy, which was confirmed at mean follow-up of 50 months (range 28 to 78). Chronic nonspecific inflammation characteristic for CRMO was present in four of seven (58%) patients, and edema with no inflammatory cells was found in three of seven (42%) patients. There was no evidence of infection in any patient. Conclusion: MRI-guided osseous biopsy is a safe and accurate technique for the diagnosis of pediatric CRMO lesions that are visible on MRI only.« less

  11. Handbook for Teachers of the Visually Handicapped.

    ERIC Educational Resources Information Center

    Napier, Grace D.; Weishahn, Mel W.

    Designed to aid the inexperienced teacher of the visually handicapped, the handbook examines aspects of program objectives, content, philosophy, methods, eligibility, and placement procedures. The guide to material selection provides specific information on the acquisition of Braille materials, large type materials, recorded materials, direct…

  12. Optical Coherence Tomography for Retinal Surgery: Perioperative Analysis to Real-Time Four-Dimensional Image-Guided Surgery.

    PubMed

    Carrasco-Zevallos, Oscar M; Keller, Brenton; Viehland, Christian; Shen, Liangbo; Seider, Michael I; Izatt, Joseph A; Toth, Cynthia A

    2016-07-01

    Magnification of the surgical field using the operating microscope facilitated profound innovations in retinal surgery in the 1970s, such as pars plana vitrectomy. Although surgical instrumentation and illumination techniques are continually developing, the operating microscope for vitreoretinal procedures has remained essentially unchanged and currently limits the surgeon's depth perception and assessment of subtle microanatomy. Optical coherence tomography (OCT) has revolutionized clinical management of retinal pathology, and its introduction into the operating suite may have a similar impact on surgical visualization and treatment. In this article, we review the evolution of OCT for retinal surgery, from perioperative analysis to live volumetric (four-dimensional, 4D) image-guided surgery. We begin by briefly addressing the benefits and limitations of the operating microscope, the progression of OCT technology, and OCT applications in clinical/perioperative retinal imaging. Next, we review intraoperative OCT (iOCT) applications using handheld probes during surgical pauses, two-dimensional (2D) microscope-integrated OCT (MIOCT) of live surgery, and volumetric MIOCT of live surgery. The iOCT discussion focuses on technological advancements, applications during human retinal surgery, translational difficulties and limitations, and future directions.

  13. Optical Coherence Tomography for Retinal Surgery: Perioperative Analysis to Real-Time Four-Dimensional Image-Guided Surgery

    PubMed Central

    Carrasco-Zevallos, Oscar M.; Keller, Brenton; Viehland, Christian; Shen, Liangbo; Seider, Michael I.; Izatt, Joseph A.; Toth, Cynthia A.

    2016-01-01

    Magnification of the surgical field using the operating microscope facilitated profound innovations in retinal surgery in the 1970s, such as pars plana vitrectomy. Although surgical instrumentation and illumination techniques are continually developing, the operating microscope for vitreoretinal procedures has remained essentially unchanged and currently limits the surgeon's depth perception and assessment of subtle microanatomy. Optical coherence tomography (OCT) has revolutionized clinical management of retinal pathology, and its introduction into the operating suite may have a similar impact on surgical visualization and treatment. In this article, we review the evolution of OCT for retinal surgery, from perioperative analysis to live volumetric (four-dimensional, 4D) image-guided surgery. We begin by briefly addressing the benefits and limitations of the operating microscope, the progression of OCT technology, and OCT applications in clinical/perioperative retinal imaging. Next, we review intraoperative OCT (iOCT) applications using handheld probes during surgical pauses, two-dimensional (2D) microscope-integrated OCT (MIOCT) of live surgery, and volumetric MIOCT of live surgery. The iOCT discussion focuses on technological advancements, applications during human retinal surgery, translational difficulties and limitations, and future directions. PMID:27409495

  14. First magnetic resonance imaging-guided aortic stenting and cava filter placement using a polyetheretherketone-based magnetic resonance imaging-compatible guidewire in swine: proof of concept.

    PubMed

    Kos, Sebastian; Huegli, Rolf; Hofmann, Eugen; Quick, Harald H; Kuehl, Hilmar; Aker, Stephanie; Kaiser, Gernot M; Borm, Paul J A; Jacob, Augustinus L; Bilecen, Deniz

    2009-05-01

    The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.

  15. First Magnetic Resonance Imaging-Guided Aortic Stenting and Cava Filter Placement Using a Polyetheretherketone-Based Magnetic Resonance Imaging-Compatible Guidewire in Swine: Proof of Concept

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kos, Sebastian, E-mail: skos@gmx.d; Huegli, Rolf; Hofmann, Eugen

    The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. Themore » guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.« less

  16. On the feasibility of MRI-guided navigation to demarcate breast cancer for breast-conserving surgery.

    PubMed

    Alderliesten, Tanja; Loo, Claudette; Paape, Anita; Muller, Sara; Rutgers, Emiel; Peeters, Marie-Jeanne Vrancken; Gilhuijs, Kenneth

    2010-06-01

    The aim of this study was to investigate the feasibility of image-guided navigation approaches to demarcate breast cancer on the basis of preacquired magnetic resonance (MR) imaging in supine patient orientation. Strategies were examined to minimize the uncertainty in the instrument-tip position, based on the hypothesis that the release of instrument pressure returns the breast tissue to its predeformed state. For this purpose, four sources of uncertainty were taken into account: (1) U(ligaments): Uncertainty in the reproducibility of the internal mammary gland geometry during repeat patient setup in supine orientation; (2) U(r_breathing): Residual uncertainty in registration of the breast after compensation for breathing motion using an external marker; (3) U(reconstruction): Uncertainty in the reconstructed location of the tip of the needle using an optical image-navigation system (phantom experiments, n = 50); and (4) U(deformation): Uncertainty in displacement of breast tumors due to needle-induced tissue deformations (patients, n = 21). A Monte Carlo study was performed to establish the 95% confidence interval (CI) of the combined uncertainties. This region of uncertainty was subsequently visualized around the reconstructed needle tip as an additional navigational aid in the preacquired MR images. Validation of the system was performed in five healthy volunteers (localization of skin markers only) and in two patients. In the patients, the navigation system was used to monitor ultrasound-guided radioactive seed localization of breast cancer. Nearest distances between the needle tip and the tumor boundary in the ultrasound images were compared to those in the concurrently reconstructed MR images. Both U(reconstruction) and U(deformation) were normally distributed with 0.1 +/- 1.2 mm (mean +/- 1 SD) and 0.1 +/- 0.8 mm, respectively. Taking prior estimates for U(ligaments) (0.0 +/- 1.5 mm) and U(r_breathing) (-0.1 +/- 0.6 mm) into account, the combined impact resulted in 3.9 mm uncertainty in the position of the needle tip (95% CI) after release of pressure. The volunteer study showed a targeting accuracy comparable to that in the phantom experiments: 2.9 +/- 1.3 versus 2.7 +/- 1.1 mm, respectively. In the patient feasibility study, the deviations were within the 3.9 mm CI. Image-guided navigation to demarcate breast cancer on the basis of preacquired MR images in supine orientation appears feasible if patient breathing is tracked during the navigation procedure, positional uncertainty is visualized and pressure on the localization instrument is released prior to verification of its position.

  17. Real-time dynamic display of registered 4D cardiac MR and ultrasound images using a GPU

    NASA Astrophysics Data System (ADS)

    Zhang, Q.; Huang, X.; Eagleson, R.; Guiraudon, G.; Peters, T. M.

    2007-03-01

    In minimally invasive image-guided surgical interventions, different imaging modalities, such as magnetic resonance imaging (MRI), computed tomography (CT), and real-time three-dimensional (3D) ultrasound (US), can provide complementary, multi-spectral image information. Multimodality dynamic image registration is a well-established approach that permits real-time diagnostic information to be enhanced by placing lower-quality real-time images within a high quality anatomical context. For the guidance of cardiac procedures, it would be valuable to register dynamic MRI or CT with intraoperative US. However, in practice, either the high computational cost prohibits such real-time visualization of volumetric multimodal images in a real-world medical environment, or else the resulting image quality is not satisfactory for accurate guidance during the intervention. Modern graphics processing units (GPUs) provide the programmability, parallelism and increased computational precision to begin to address this problem. In this work, we first outline our research on dynamic 3D cardiac MR and US image acquisition, real-time dual-modality registration and US tracking. Then we describe image processing and optimization techniques for 4D (3D + time) cardiac image real-time rendering. We also present our multimodality 4D medical image visualization engine, which directly runs on a GPU in real-time by exploiting the advantages of the graphics hardware. In addition, techniques such as multiple transfer functions for different imaging modalities, dynamic texture binding, advanced texture sampling and multimodality image compositing are employed to facilitate the real-time display and manipulation of the registered dual-modality dynamic 3D MR and US cardiac datasets.

  18. Advanced Medical Technology and Network Systems Research.

    DTIC Science & Technology

    1999-09-01

    for image-guided therapies . Advanced technologies included in this report are impedance imaging and a palpation training system. 14. SUBJECT...Summary 1 Virtual Clinic for Patients with Chronic Illness Project Planning Document • 2 Telemedicine for Hemodialysis 21 A...imaging systems and’ surgical procedures effort is accomplished in part by establishing the technology requirements for image-guided therapies . Advanced

  19. Image-guided surgery.

    PubMed

    Wagner, A; Ploder, O; Enislidis, G; Truppe, M; Ewers, R

    1996-04-01

    Interventional video tomography (IVT), a new imaging modality, achieves virtual visualization of anatomic structures in three dimensions for intraoperative stereotactic navigation. Partial immersion into a virtual data space, which is orthotopically coregistered to the surgical field, enhances, by means of a see-through head-mounted display (HMD), the surgeon's visual perception and technique by providing visual access to nonvisual data of anatomy, physiology, and function. The presented cases document the potential of augmented reality environments in maxillofacial surgery.

  20. MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement

    PubMed Central

    Fischer, Gregory S.; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; DiMaio, Simon P.; Tempany, Clare M.; Hata, Nobuhiko; Fichtinger, Gabor

    2010-01-01

    Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intraprostatic needle placement inside closed high-field MRI scanners. MRI compatibility of the robot has been evaluated under 3T MRI using standard prostate imaging sequences and average SNR loss is limited to 5%. Needle alignment accuracy of the robot under servo pneumatic control is better than 0.94 mm rms per axis. The complete system workflow has been evaluated in phantom studies with accurate visualization and targeting of five out of five 1 cm targets. The paper explains the robot mechanism and controller design, the system integration, and presents results of preliminary evaluation of the system. PMID:21057608

  1. Colour for Behavioural Success.

    PubMed

    Dresp-Langley, Birgitta; Reeves, Adam

    2018-01-01

    Colour information not only helps sustain the survival of animal species by guiding sexual selection and foraging behaviour but also is an important factor in the cultural and technological development of our own species. This is illustrated by examples from the visual arts and from state-of-the-art imaging technology, where the strategic use of colour has become a powerful tool for guiding the planning and execution of interventional procedures. The functional role of colour information in terms of its potential benefits to behavioural success across the species is addressed in the introduction here to clarify why colour perception may have evolved to generate behavioural success. It is argued that evolutionary and environmental pressures influence not only colour trait production in the different species but also their ability to process and exploit colour information for goal-specific purposes. We then leap straight to the human primate with insight from current research on the facilitating role of colour cues on performance training with precision technology for image-guided surgical planning and intervention. It is shown that local colour cues in two-dimensional images generated by a surgical fisheye camera help individuals become more precise rapidly across a limited number of trial sets in simulator training for specific manual gestures with a tool. This facilitating effect of a local colour cue on performance evolution in a video-controlled simulator (pick-and-place) task can be explained in terms of colour-based figure-ground segregation facilitating attention to local image parts when more than two layers of subjective surface depth are present, as in all natural and surgical images.

  2. Colour for Behavioural Success

    PubMed Central

    Reeves, Adam

    2018-01-01

    Colour information not only helps sustain the survival of animal species by guiding sexual selection and foraging behaviour but also is an important factor in the cultural and technological development of our own species. This is illustrated by examples from the visual arts and from state-of-the-art imaging technology, where the strategic use of colour has become a powerful tool for guiding the planning and execution of interventional procedures. The functional role of colour information in terms of its potential benefits to behavioural success across the species is addressed in the introduction here to clarify why colour perception may have evolved to generate behavioural success. It is argued that evolutionary and environmental pressures influence not only colour trait production in the different species but also their ability to process and exploit colour information for goal-specific purposes. We then leap straight to the human primate with insight from current research on the facilitating role of colour cues on performance training with precision technology for image-guided surgical planning and intervention. It is shown that local colour cues in two-dimensional images generated by a surgical fisheye camera help individuals become more precise rapidly across a limited number of trial sets in simulator training for specific manual gestures with a tool. This facilitating effect of a local colour cue on performance evolution in a video-controlled simulator (pick-and-place) task can be explained in terms of colour-based figure-ground segregation facilitating attention to local image parts when more than two layers of subjective surface depth are present, as in all natural and surgical images. PMID:29770183

  3. Feasibility study for image guided kidney surgery: assessment of required intraoperative surface for accurate image to physical space registrations

    NASA Astrophysics Data System (ADS)

    Benincasa, Anne B.; Clements, Logan W.; Herrell, S. Duke; Chang, Sam S.; Cookson, Michael S.; Galloway, Robert L.

    2006-03-01

    Currently, the removal of kidney tumor masses uses only direct or laparoscopic visualizations, resulting in prolonged procedure and recovery times and reduced clear margin. Applying current image guided surgery (IGS) techniques, as those used in liver cases, to kidney resections (nephrectomies) presents a number of complications. Most notably is the limited field of view of the intraoperative kidney surface, which constrains the ability to obtain a surface delineation that is geometrically descriptive enough to drive a surface-based registration. Two different phantom orientations were used to model the laparoscopic and traditional partial nephrectomy views. For the laparoscopic view, fiducial point sets were compiled from a CT image volume using anatomical features such as the renal artery and vein. For the traditional view, markers attached to the phantom set-up were used for fiducials and targets. The fiducial points were used to perform a point-based registration, which then served as a guide for the surface-based registration. Laser range scanner (LRS) obtained surfaces were registered to each phantom surface using a rigid iterative closest point algorithm. Subsets of each phantom's LRS surface were used in a robustness test to determine the predictability of their registrations to transform the entire surface. Results from both orientations suggest that about half of the kidney's surface needs to be obtained intraoperatively for accurate registrations between the image surface and the LRS surface, suggesting the obtained kidney surfaces were geometrically descriptive enough to perform accurate registrations. This preliminary work paves the way for further development of kidney IGS systems.

  4. Infrared needle mapping to assist biopsy procedures and training.

    PubMed

    Shar, Bruce; Leis, John; Coucher, John

    2018-04-01

    A computed tomography (CT) biopsy is a radiological procedure which involves using a needle to withdraw tissue or a fluid specimen from a lesion of interest inside a patient's body. The needle is progressively advanced into the patient's body, guided by the most recent CT scan. CT guided biopsies invariably expose patients to high dosages of radiation, due to the number of scans required whilst the needle is advanced. This study details the design of a novel method to aid biopsy procedures using infrared cameras. Two cameras are used to image the biopsy needle area, from which the proposed algorithm computes an estimate of the needle endpoint, which is projected onto the CT image space. This estimated position may be used to guide the needle between scans, and results in a reduction in the number of CT scans that need to be performed during the biopsy procedure. The authors formulate a 2D augmentation system which compensates for camera pose, and show that multiple low-cost infrared imaging devices provide a promising approach.

  5. Saline as the Sole Contrast Agent for Successful MRI-guided Epidural Injections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deli, Martin, E-mail: martin.deli@web.de; Fritz, Jan, E-mail: jfritz9@jhmi.edu; Mateiescu, Serban, E-mail: mateiescu@microtherapy.de

    Purpose. To assess the performance of sterile saline solution as the sole contrast agent for percutaneous magnetic resonance imaging (MRI)-guided epidural injections at 1.5 T. Methods. A retrospective analysis of two different techniques of MRI-guided epidural injections was performed with either gadolinium-enhanced saline solution or sterile saline solution for documentation of the epidural location of the needle tip. T1-weighted spoiled gradient echo (FLASH) images or T2-weighted single-shot turbo spin echo (HASTE) images visualized the test injectants. Methods were compared by technical success rate, image quality, table time, and rate of complications. Results. 105 MRI-guided epidural injections (12 of 105 withmore » gadolinium-enhanced saline solution and 93 of 105 with sterile saline solution) were performed successfully and without complications. Visualization of sterile saline solution and gadolinium-enhanced saline solution was sufficient, good, or excellent in all 105 interventions. For either test injectant, quantitative image analysis demonstrated comparable high contrast-to-noise ratios of test injectants to adjacent body substances with reliable statistical significance levels (p < 0.001). The mean table time was 22 {+-} 9 min in the gadolinium-enhanced saline solution group and 22 {+-} 8 min in the saline solution group (p = 0.75). Conclusion. Sterile saline is suitable as the sole contrast agent for successful and safe percutaneous MRI-guided epidural drug delivery at 1.5 T.« less

  6. Evidence that primary visual cortex is required for image, orientation, and motion discrimination by rats.

    PubMed

    Petruno, Sarah K; Clark, Robert E; Reinagel, Pamela

    2013-01-01

    The pigmented Long-Evans rat has proven to be an excellent subject for studying visually guided behavior including quantitative visual psychophysics. This observation, together with its experimental accessibility and its close homology to the mouse, has made it an attractive model system in which to dissect the thalamic and cortical circuits underlying visual perception. Given that visually guided behavior in the absence of primary visual cortex has been described in the literature, however, it is an empirical question whether specific visual behaviors will depend on primary visual cortex in the rat. Here we tested the effects of cortical lesions on performance of two-alternative forced-choice visual discriminations by Long-Evans rats. We present data from one highly informative subject that learned several visual tasks and then received a bilateral lesion ablating >90% of primary visual cortex. After the lesion, this subject had a profound and persistent deficit in complex image discrimination, orientation discrimination, and full-field optic flow motion discrimination, compared with both pre-lesion performance and sham-lesion controls. Performance was intact, however, on another visual two-alternative forced-choice task that required approaching a salient visual target. A second highly informative subject learned several visual tasks prior to receiving a lesion ablating >90% of medial extrastriate cortex. This subject showed no impairment on any of the four task categories. Taken together, our data provide evidence that these image, orientation, and motion discrimination tasks require primary visual cortex in the Long-Evans rat, whereas approaching a salient visual target does not.

  7. Multifunctional Catheters Combining Intracardiac Ultrasound Imaging and Electrophysiology Sensing

    PubMed Central

    Stephens, Douglas N.; Cannata, Jonathan; Liu, Ruibin; Zhao, Jian Zhong; Shung, K. Kirk; Nguyen, Hien; Chia, Raymond; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai E.; Mahajan, Aman; Shivkumar, Kalyanam; Kim, Kang; O’Donnell, Matthew; Nikoozadeh, Amin; Oralkan, Omer; Khuri-Yakub, Pierre T.; Sahn, David J.

    2015-01-01

    A family of 3 multifunctional intracardiac imaging and electrophysiology (EP) mapping catheters has been in development to help guide diagnostic and therapeutic intracardiac EP procedures. The catheter tip on the first device includes a 7.5 MHz, 64-element, side-looking phased array for high resolution sector scanning. The second device is a forward-looking catheter with a 24-element 14 MHz phased array. Both of these catheters operate on a commercial imaging system with standard software. Multiple EP mapping sensors were mounted as ring electrodes near the arrays for electrocardiographic synchronization of ultrasound images and used for unique integration with EP mapping technologies. To help establish the catheters’ ability for integration with EP interventional procedures, tests were performed in vivo in a porcine animal model to demonstrate both useful intracardiac echocardiographic (ICE) visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheters also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. The companion paper of this work discusses the catheter design of the side-looking catheter with special attention to acoustic lens design. The third device in development is a 10 MHz forward-looking ring array that is to be mounted at the distal tip of a 9F catheter to permit use of the available catheter lumen for adjunctive therapy tools. PMID:18986948

  8. Multifunctional catheters combining intracardiac ultrasound imaging and electrophysiology sensing.

    PubMed

    Stephens, D N; Cannata, J; Liu, Ruibin; Zhao, Jian Zhong; Shung, K K; Nguyen, Hien; Chia, R; Dentinger, A; Wildes, D; Thomenius, K E; Mahajan, A; Shivkumar, K; Kim, Kang; O'Donnell, M; Nikoozadeh, A; Oralkan, O; Khuri-Yakub, P T; Sahn, D J

    2008-07-01

    A family of 3 multifunctional intracardiac imaging and electrophysiology (EP) mapping catheters has been in development to help guide diagnostic and therapeutic intracardiac EP procedures. The catheter tip on the first device includes a 7.5 MHz, 64-element, side-looking phased array for high resolution sector scanning. The second device is a forward-looking catheter with a 24-element 14 MHz phased array. Both of these catheters operate on a commercial imaging system with standard software. Multiple EP mapping sensors were mounted as ring electrodes near the arrays for electrocardiographic synchronization of ultrasound images and used for unique integration with EP mapping technologies. To help establish the catheters' ability for integration with EP interventional procedures, tests were performed in vivo in a porcine animal model to demonstrate both useful intracardiac echocardiographic (ICE) visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheters also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. The companion paper of this work discusses the catheter design of the side-looking catheter with special attention to acoustic lens design. The third device in development is a 10 MHz forward-looking ring array that is to be mounted at the distal tip of a 9F catheter to permit use of the available catheter lumen for adjunctive therapy tools.

  9. Mechanically assisted 3D ultrasound for pre-operative assessment and guiding percutaneous treatment of focal liver tumors

    NASA Astrophysics Data System (ADS)

    Sadeghi Neshat, Hamid; Bax, Jeffery; Barker, Kevin; Gardi, Lori; Chedalavada, Jason; Kakani, Nirmal; Fenster, Aaron

    2014-03-01

    Image-guided percutaneous ablation is the standard treatment for focal liver tumors deemed inoperable and is commonly used to maintain eligibility for patients on transplant waitlists. Radiofrequency (RFA), microwave (MWA) and cryoablation technologies are all delivered via one or a number of needle-shaped probes inserted directly into the tumor. Planning is mostly based on contrast CT/MRI. While intra-procedural CT is commonly used to confirm the intended probe placement, 2D ultrasound (US) remains the main, and in some centers the only imaging modality used for needle guidance. Corresponding intraoperative 2D US with planning and other intra-procedural imaging modalities is essential for accurate needle placement. However, identification of matching features of interest among these images is often challenging given the limited field-of-view (FOV) and low quality of 2D US images. We have developed a passive tracking arm with a motorized scan-head and software tools to improve guiding capabilities of conventional US by large FOV 3D US scans that provides more anatomical landmarks that can facilitate registration of US with both planning and intra-procedural images. The tracker arm is used to scan the whole liver with a high geometrical accuracy that facilitates multi-modality landmark based image registration. Software tools are provided to assist with the segmentation of the ablation probes and tumors, find the 2D view that best shows the probe(s) from a 3D US image, and to identify the corresponding image from planning CT scans. In this paper, evaluation results from laboratory testing and a phase 1 clinical trial for planning and guiding RFA and MWA procedures using the developed system will be presented. Early clinical results show a comparable performance to intra-procedural CT that suggests 3D US as a cost-effective alternative with no side-effects in centers where CT is not available.

  10. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) ablation of liver tumours.

    PubMed

    Wijlemans, J W; Bartels, L W; Deckers, R; Ries, M; Mali, W P Th M; Moonen, C T W; van den Bosch, M A A J

    2012-09-28

    Recent decades have seen a paradigm shift in the treatment of liver tumours from invasive surgical procedures to minimally invasive image-guided ablation techniques. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a novel, completely non-invasive ablation technique that has the potential to change the field of liver tumour ablation. The image guidance, using MR imaging and MR temperature mapping, provides excellent planning images and real-time temperature information during the ablation procedure. However, before clinical implementation of MR-HIFU for liver tumour ablation is feasible, several organ-specific challenges have to be addressed. In this review we discuss the MR-HIFU ablation technique, the liver-specific challenges for MR-HIFU tumour ablation, and the proposed solutions for clinical translation.

  11. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) ablation of liver tumours

    PubMed Central

    Bartels, L.W.; Deckers, R.; Ries, M.; Mali, W.P.Th.M.; Moonen, C.T.W.; van den Bosch, M.A.A.J.

    2012-01-01

    Abstract Recent decades have seen a paradigm shift in the treatment of liver tumours from invasive surgical procedures to minimally invasive image-guided ablation techniques. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a novel, completely non-invasive ablation technique that has the potential to change the field of liver tumour ablation. The image guidance, using MR imaging and MR temperature mapping, provides excellent planning images and real-time temperature information during the ablation procedure. However, before clinical implementation of MR-HIFU for liver tumour ablation is feasible, several organ-specific challenges have to be addressed. In this review we discuss the MR-HIFU ablation technique, the liver-specific challenges for MR-HIFU tumour ablation, and the proposed solutions for clinical translation. PMID:23022541

  12. Contrast-enhanced cardiac C-arm CT evaluation of radiofrequency ablation lesions in the left ventricle

    PubMed Central

    Girard, Erin E; Al-Ahmad, Amin A; Rosenberg, Jarrett; Luong, Richard; Moore, Teri; Lauritsch, Günter; Boese, Jan; Fahrig, Rebecca

    2011-01-01

    Objectives The purpose of this study was to evaluate use of cardiac C-arm computed tomography (CT) in the assessment of the dimensions and temporal characteristics of radiofrequency ablation (RFA) lesions. This imaging modality uses a standard C-arm fluoroscopy system rotating around the patient, providing CT-like images during the RFA procedure. Background Both magnetic resonance imaging (MRI) and CT can be used to assess myocardial necrotic tissue. Several studies have reported visualizing cardiac RF ablation lesions with MRI, however obtaining MR images during interventional procedures is not common practice. Direct visualization of RFA lesions using C-arm CT during the procedure may improve outcomes and circumvent complications associated with cardiac ablation procedures. Methods RFA lesions were created on the endocardial surface of the left ventricle of 9 swine using a 7-F RF ablation catheter. An ECG-gated C-arm CT imaging protocol was used to acquire projection images during iodine contrast injection and following the injection every 5 min for up to 30 min, with no additional contrast. Reconstructed images were analyzed offline. The mean and standard deviation of the signal intensity of the lesion and normal myocardium were measured in all images in each time series. Lesion dimensions and area were measured and compared in pathologic specimens and C-arm CT images. Results All ablation lesions (n=29) were visualized and lesion dimensions, as measured on C-arm CT, correlated well with postmortem tissue measurements (1D dimensions : concordance correlation = 0.87; area : concordance correlation = 0.90). Lesions were visualized as a perfusion defect on first-pass C-arm CT images with a signal intensity 95 HU lower than normal myocardium (95% confidence interval: -111 to -79 HU). Images acquired at 1 and 5 minutes exhibited an enhancing ring surrounding the perfusion defect in 24 (83%) lesions. Conclusions RFA lesion size, including transmurality, can be assessed using ECG-gated cardiac C-arm CT in the interventional suite. Visualization of RFA lesions using cardiac C-arm CT may facilitate the assessment of adequate lesion delivery and provide valuable feedback during cardiac ablation procedures. PMID:21414574

  13. Real-time Magnetic Resonance Imaging Guidance for Cardiovascular Procedures

    PubMed Central

    Horvath, Keith A.; Li, Ming; Mazilu, Dumitru; Guttman, Michael A.; McVeigh, Elliot R.

    2008-01-01

    Magnetic resonance imaging (MRI) of the cardiovascular system has proven to be an invaluable diagnostic tool. Given the ability to allow for real-time imaging, MRI guidance of intraoperative procedures can provide superb visualization which can facilitate a variety of interventions and minimize the trauma of the operations as well. In addition to the anatomic detail, MRI can provide intraoperative assessment of organ and device function. Instruments and devices can be marked to enhance visualization and tracking. All of which is an advance over standard x-ray or ultrasonic imaging. PMID:18395633

  14. Visually guided male urinary catheterization: a feasibility study.

    PubMed

    Willette, Paul A; Banks, Kevin; Shaffer, Lynn

    2013-01-01

    Ten percent to 15% of urinary catheterizations involve complications. New techniques to reduce risks and pain are indicated. This study examines the feasibility and safety of male urinary catheterization by nursing personnel using a visually guided device in a clinical setting. The device, a 0.6-mm fiber-optic bundle inside a 14F triple-lumen flexible urinary catheter with a lubricious coating, irrigation port, and angled tip, connects to a camera, allowing real-time viewing of progress on a color monitor. Two emergency nurses were trained to use the device. Male patients 18 years or older presenting to the emergency department with an indication for urinary catheterization using a standard Foley or Coudé catheter were eligible to participate in the study. Exclusion criteria were a current suprapubic tube or gross hematuria prior to the procedure. Twenty-five patients were enrolled. Data collected included success of placement, total procedure time, pre-procedure pain and maximum pain during the procedure, gross hematuria, abnormalities or injuries identified if catheterization failed, occurrence of and reason for equipment failures, and number of passes required for placement. All catheters were successfully placed. The median number of passes required was 1. For all but one patient, procedure time was ≤ 17 minutes. A median increase in pain scores of 1 point from baseline to the maximum was reported. Gross hematuria was observed in 2 patients. The success rate for placement of a Foley catheter with the visually guided device was 100%, indicating its safety, accuracy, and feasibility in a clinical setting. Minimal pain was associated with the procedure. Copyright © 2013 Emergency Nurses Association. Published by Mosby, Inc. All rights reserved.

  15. IMAGE-GUIDED EVALUATION AND MONITORING OF TREATMENT RESPONSE IN PATIENTS WITH DRY EYE DISEASE

    PubMed Central

    Hamrah, Pedram

    2014-01-01

    Dry eye disease (DED) is one of the most common ocular disorders worldwide. The pathophysiological mechanisms involved in the development of DED are not well understood and thus treating DED has been a significant challenge for ophthalmologists. Most of the currently available diagnostic tests demonstrate low correlation to patient symptoms and have low reproducibility. Recently, sophisticated in vivo imaging modalities have become available for patient care, namely, in vivo confocal microscopy (IVCM) and optical coherence tomography (OCT). These emerging modalities are powerful and non-invasive, allowing real-time visualization of cellular and anatomical structures of the cornea and ocular surface. Here we discuss how, by providing both qualitative and quantitative assessment, these techniques can be used to demonstrate early subclinical disease, grade layer-by-layer severity, and allow monitoring of disease severity by cellular alterations. Imaging-guided stratification of patients may also be possible in conjunction with clinical examination methods. Visualization of subclinical changes and stratification of patients in vivo, allows objective image-guided evaluation of tailored treatment response based on cellular morphological alterations specific to each patient. This image-guided approach to DED may ultimately improve patient outcomes and allow studying the efficacy of novel therapies in clinical trials. PMID:24696045

  16. Review of the potential of optical technologies for cancer diagnosis in neurosurgery: a step toward intraoperative neurophotonics

    PubMed Central

    Vasefi, Fartash; MacKinnon, Nicholas; Farkas, Daniel L.; Kateb, Babak

    2016-01-01

    Abstract. Advances in image-guided therapy enable physicians to obtain real-time information on neurological disorders such as brain tumors to improve resection accuracy. Image guidance data include the location, size, shape, type, and extent of tumors. Recent technological advances in neurophotonic engineering have enabled the development of techniques for minimally invasive neurosurgery. Incorporation of these methods in intraoperative imaging decreases surgical procedure time and allows neurosurgeons to find remaining or hidden tumor or epileptic lesions. This facilitates more complete resection and improved topology information for postsurgical therapy (i.e., radiation). We review the clinical application of recent advances in neurophotonic technologies including Raman spectroscopy, thermal imaging, optical coherence tomography, and fluorescence spectroscopy, highlighting the importance of these technologies in live intraoperative tissue mapping during neurosurgery. While these technologies need further validation in larger clinical trials, they show remarkable promise in their ability to help surgeons to better visualize the areas of abnormality and enable safe and successful removal of malignancies. PMID:28042588

  17. Fluorescence-guided surgery and intervention - An AAPM emerging technology blue paper.

    PubMed

    Pogue, Brian W; Zhu, Timothy C; Ntziachristos, Vasilis; Paulsen, Keith D; Wilson, Brian C; Pfefer, Joshua; Nordstrom, Robert J; Litorja, Maritoni; Wabnitz, Heidrun; Chen, Yu; Gioux, Sylvain; Tromberg, Bruce J; Yodh, Arjun G

    2018-04-10

    Fluorescence-guided surgery (FGS) and other interventions are rapidly evolving as a class of technologically driven interventional approaches in which many surgical specialties visualize fluorescent molecular tracers or biomarkers through associated cameras or oculars to guide clinical decisions on pathological lesion detection and excision/ablation. The technology has been commercialized for some specific applications, but also presents technical challenges unique to optical imaging that could confound the utility of some interventional procedures where real-time decisions must be made. Accordingly, the AAPM has initiated the publication of this Blue Paper of The Emerging Technology Working Group (TETAWG) and the creation of a Task Group from the Therapy Physics Committee within the Treatment Delivery Subcommittee. In describing the relevant issues, this document outlines the key parameters, stakeholders, impacts, and outcomes of clinical FGS technology and its applications. The presentation is not intended to be conclusive, but rather to inform the field of medical physics and stimulate the discussions needed in the field with respect to a seemingly low-risk imaging technology that has high potential for significant therapeutic impact. This AAPM Task Group is working toward consensus around guidelines and standards for advancing the field safely and effectively. © 2018 American Association of Physicists in Medicine.

  18. An augmented parametric response map with consideration of image registration error: towards guidance of locally adaptive radiotherapy

    NASA Astrophysics Data System (ADS)

    Lausch, Anthony; Chen, Jeff; Ward, Aaron D.; Gaede, Stewart; Lee, Ting-Yim; Wong, Eugene

    2014-11-01

    Parametric response map (PRM) analysis is a voxel-wise technique for predicting overall treatment outcome, which shows promise as a tool for guiding personalized locally adaptive radiotherapy (RT). However, image registration error (IRE) introduces uncertainty into this analysis which may limit its use for guiding RT. Here we extend the PRM method to include an IRE-related PRM analysis confidence interval and also incorporate multiple graded classification thresholds to facilitate visualization. A Gaussian IRE model was used to compute an expected value and confidence interval for PRM analysis. The augmented PRM (A-PRM) was evaluated using CT-perfusion functional image data from patients treated with RT for glioma and hepatocellular carcinoma. Known rigid IREs were simulated by applying one thousand different rigid transformations to each image set. PRM and A-PRM analyses of the transformed images were then compared to analyses of the original images (ground truth) in order to investigate the two methods in the presence of controlled IRE. The A-PRM was shown to help visualize and quantify IRE-related analysis uncertainty. The use of multiple graded classification thresholds also provided additional contextual information which could be useful for visually identifying adaptive RT targets (e.g. sub-volume boosts). The A-PRM should facilitate reliable PRM guided adaptive RT by allowing the user to identify if a patient’s unique IRE-related PRM analysis uncertainty has the potential to influence target delineation.

  19. Registration of angiographic image on real-time fluoroscopic image for image-guided percutaneous coronary intervention.

    PubMed

    Kim, Dongkue; Park, Sangsoo; Jeong, Myung Ho; Ryu, Jeha

    2018-02-01

    In percutaneous coronary intervention (PCI), cardiologists must study two different X-ray image sources: a fluoroscopic image and an angiogram. Manipulating a guidewire while alternately monitoring the two separate images on separate screens requires a deep understanding of the anatomy of coronary vessels and substantial training. We propose 2D/2D spatiotemporal image registration of the two images in a single image in order to provide cardiologists with enhanced visual guidance in PCI. The proposed 2D/2D spatiotemporal registration method uses a cross-correlation of two ECG series in each image to temporally synchronize two separate images and register an angiographic image onto the fluoroscopic image. A guidewire centerline is then extracted from the fluoroscopic image in real time, and the alignment of the centerline with vessel outlines of the chosen angiographic image is optimized using the iterative closest point algorithm for spatial registration. A proof-of-concept evaluation with a phantom coronary vessel model with engineering students showed an error reduction rate greater than 74% on wrong insertion to nontarget branches compared to the non-registration method and more than 47% reduction in the task completion time in performing guidewire manipulation for very difficult tasks. Evaluation with a small number of experienced doctors shows a potentially significant reduction in both task completion time and error rate for difficult tasks. The total registration time with real procedure X-ray (angiographic and fluoroscopic) images takes [Formula: see text] 60 ms, which is within the fluoroscopic image acquisition rate of 15 Hz. By providing cardiologists with better visual guidance in PCI, the proposed spatiotemporal image registration method is shown to be useful in advancing the guidewire to the coronary vessel branches, especially those difficult to insert into.

  20. Real-time magnetic resonance imaging-guided radiofrequency atrial ablation and visualization of lesion formation at 3 Tesla.

    PubMed

    Vergara, Gaston R; Vijayakumar, Sathya; Kholmovski, Eugene G; Blauer, Joshua J E; Guttman, Mike A; Gloschat, Christopher; Payne, Gene; Vij, Kamal; Akoum, Nazem W; Daccarett, Marcos; McGann, Christopher J; Macleod, Rob S; Marrouche, Nassir F

    2011-02-01

    Magnetic resonance imaging (MRI) allows visualization of location and extent of radiofrequency (RF) ablation lesion, myocardial scar formation, and real-time (RT) assessment of lesion formation. In this study, we report a novel 3-Tesla RT -RI based porcine RF ablation model and visualization of lesion formation in the atrium during RF energy delivery. The purpose of this study was to develop a 3-Tesla RT MRI-based catheter ablation and lesion visualization system. RF energy was delivered to six pigs under RT MRI guidance. A novel MRI-compatible mapping and ablation catheter was used. Under RT MRI, this catheter was safely guided and positioned within either the left or right atrium. Unipolar and bipolar electrograms were recorded. The catheter tip-tissue interface was visualized with a T1-weighted gradient echo sequence. RF energy was then delivered in a power-controlled fashion. Myocardial changes and lesion formation were visualized with a T2-weighted (T2W) half Fourier acquisition with single-shot turbo spin echo (HASTE) sequence during ablation. RT visualization of lesion formation was achieved in 30% of the ablations performed. In the other cases, either the lesion was formed outside the imaged region (25%) or the lesion was not created (45%) presumably due to poor tissue-catheter tip contact. The presence of lesions was confirmed by late gadolinium enhancement MRI and macroscopic tissue examination. MRI-compatible catheters can be navigated and RF energy safely delivered under 3-Tesla RT MRI guidance. Recording electrograms during RT imaging also is feasible. RT visualization of lesion as it forms during RF energy delivery is possible and was demonstrated using T2W HASTE imaging. Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  1. Creative Arts and Crafts for Children with Visual Handicaps.

    ERIC Educational Resources Information Center

    Sykes, Kim C.; And Others

    This teaching guide gives instructions for 23 creative art or craft projects thought to be appropriate for use with visually handicapped children. Usually included for each project are the educational objective, materials and equipment needed, procedure, possible variations, and photographs. The following types of activity are recommended: tempera…

  2. Tracking with the mind's eye

    NASA Technical Reports Server (NTRS)

    Krauzlis, R. J.; Stone, L. S.

    1999-01-01

    The two components of voluntary tracking eye-movements in primates, pursuit and saccades, are generally viewed as relatively independent oculomotor subsystems that move the eyes in different ways using independent visual information. Although saccades have long been known to be guided by visual processes related to perception and cognition, only recently have psychophysical and physiological studies provided compelling evidence that pursuit is also guided by such higher-order visual processes, rather than by the raw retinal stimulus. Pursuit and saccades also do not appear to be entirely independent anatomical systems, but involve overlapping neural mechanisms that might be important for coordinating these two types of eye movement during the tracking of a selected visual object. Given that the recovery of objects from real-world images is inherently ambiguous, guiding both pursuit and saccades with perception could represent an explicit strategy for ensuring that these two motor actions are driven by a single visual interpretation.

  3. SimITK: rapid ITK prototyping using the Simulink visual programming environment

    NASA Astrophysics Data System (ADS)

    Dickinson, A. W. L.; Mousavi, P.; Gobbi, D. G.; Abolmaesumi, P.

    2011-03-01

    The Insight Segmentation and Registration Toolkit (ITK) is a long-established, software package used for image analysis, visualization, and image-guided surgery applications. This package is a collection of C++ libraries, that can pose usability problems for users without C++ programming experience. To bridge the gap between the programming complexities and the required learning curve of ITK, we present a higher-level visual programming environment that represents ITK methods and classes by wrapping them into "blocks" within MATLAB's visual programming environment, Simulink. These blocks can be connected to form workflows: visual schematics that closely represent the structure of a C++ program. Due to the heavily C++ templated nature of ITK, direct interaction between Simulink and ITK requires an intermediary to convert their respective datatypes and allow intercommunication. We have developed a "Virtual Block" that serves as an intermediate wrapper around the ITK class and is responsible for resolving the templated datatypes used by ITK to native types used by Simulink. Presently, the wrapping procedure for SimITK is semi-automatic in that it requires XML descriptions of the ITK classes as a starting point, as this data is used to create all other necessary integration files. The generation of all source code and object code from the XML is done automatically by a CMake build script that yields Simulink blocks as the final result. An example 3D segmentation workflow using cranial-CT data as well as a 3D MR-to-CT registration workflow are presented as a proof-of-concept.

  4. [Basic concept in computer assisted surgery].

    PubMed

    Merloz, Philippe; Wu, Hao

    2006-03-01

    To investigate application of medical digital imaging systems and computer technologies in orthopedics. The main computer-assisted surgery systems comprise the four following subcategories. (1) A collection and recording process for digital data on each patient, including preoperative images (CT scans, MRI, standard X-rays), intraoperative visualization (fluoroscopy, ultrasound), and intraoperative position and orientation of surgical instruments or bone sections (using 3D localises). Data merging based on the matching of preoperative imaging (CT scans, MRI, standard X-rays) and intraoperative visualization (anatomical landmarks, or bone surfaces digitized intraoperatively via 3D localiser; intraoperative ultrasound images processed for delineation of bone contours). (2) In cases where only intraoperative images are used for computer-assisted surgical navigation, the calibration of the intraoperative imaging system replaces the merged data system, which is then no longer necessary. (3) A system that provides aid in decision-making, so that the surgical approach is planned on basis of multimodal information: the interactive positioning of surgical instruments or bone sections transmitted via pre- or intraoperative images, display of elements to guide surgical navigation (direction, axis, orientation, length and diameter of a surgical instrument, impingement, etc. ). And (4) A system that monitors the surgical procedure, thereby ensuring that the optimal strategy defined at the preoperative stage is taken into account. It is possible that computer-assisted orthopedic surgery systems will enable surgeons to better assess the accuracy and reliability of the various operative techniques, an indispensable stage in the optimization of surgery.

  5. Distribution of guidance models for cardiac resynchronization therapy in the setting of multi-center clinical trials

    NASA Astrophysics Data System (ADS)

    Rajchl, Martin; Abhari, Kamyar; Stirrat, John; Ukwatta, Eranga; Cantor, Diego; Li, Feng P.; Peters, Terry M.; White, James A.

    2014-03-01

    Multi-center trials provide the unique ability to investigate novel techniques across a range of geographical sites with sufficient statistical power, the inclusion of multiple operators determining feasibility under a wider array of clinical environments and work-flows. For this purpose, we introduce a new means of distributing pre-procedural cardiac models for image-guided interventions across a large scale multi-center trial. In this method, a single core facility is responsible for image processing, employing a novel web-based interface for model visualization and distribution. The requirements for such an interface, being WebGL-based, are minimal and well within the realms of accessibility for participating centers. We then demonstrate the accuracy of our approach using a single-center pacemaker lead implantation trial with generic planning models.

  6. Endoscopic trans-nasal approach for biopsy of orbital tumours using image-guided neuro-navigation system.

    PubMed

    Sieskiewicz, A; Lyson, T; Mariak, Z; Rogowski, M

    2008-05-01

    Histopathological diagnosis of intraorbital tumours is of crucial value for planning further therapy. The aim of the study was to explore clinical utility of image-guided endoscopy for biopsy of orbital tumours. Trans-nasal endoscopic biopsy of intraorbital mass lesions was performed in 6 patients using a neuro-navigation system (Medtronic Stealth Station Treon plus). The CT and MRI 1 mm slice images were fused by the system in order to visualise both bony and soft tissue structures. The anatomic fiducial registration protocol was used during the procedure. All lesions were precisely localised and the biopsies could be taken from the representative part of the pathological mass. None of the patients developed aggravation of ocular symptoms after the procedure. The operative corridor as well as the size of orbital wall fenestration could be limited to a minimum. The accuracy of neuro-navigation remained high and stable during the entire procedure. The image-guided neuro-navigation system facilitated endoscopic localisation and biopsy of intraorbital tumours and contributed to the reduction of surgical trauma during the procedure. The technique was particularly useful in small, medially located, retrobulbar tumours and in unclear situations when the structure of the lesion resembled surrounding intraorbital tissue.

  7. Flexible Ultrathin Endoscope Integrated with Irrigation Suction Apparatus for Assisting Microneurosurgery.

    PubMed

    Otani, Naoki; Morimoto, Yuji; Fujii, Kazuya; Toyooka, Terushige; Wada, Kojiro; Mori, Kentaro

    2017-12-01

    Endoscopy can observe the anatomical components in a deeply located and/or hidden area during neurosurgical procedures under the operating microscope. We have newly developed a flexible ultrathin endoscope integrated with irrigation suction apparatus (FUEISA) to visualize deeply located and/or hidden areas for assisting microneurosurgery. The present study investigated the usefulness of the FUEISA system for direct clipping surgery of cerebral aneurysms. Twenty-one patients underwent microneurosurgery assisted with the FUEISA system for direct clipping of cerebral aneurysms. The flexible ultrathin endoscope (outer diameter 0.75mm) consists of an image guide (6000 dpi) and a light guide, integrated with the irrigation suction apparatus. This endoscopic system was inserted before and after clipping to observe the anatomical conditions surrounding the lesions. In all cases, handling and operation of the FUEISA was technically successful during the surgical procedure. The ultrathin endoscope was adequately integrated with the irrigation suction apparatus in all cases. General anatomy visualization including the lenticulostriate arteries, medial striate arteries, and/or internal carotid artery perforators was possible, and the correct clip positioning and vessel conditions were easily checked. The endoscope revealed that the clip had been positioned incorrectly in one case. No complications associated with the endoscopic system occurred. The FUEISA system can be applied with safe manipulation, which was remarkably useful for confirmation of the presence of perforators and cranial nerves behind the lesions, particularly anatomical components located in deep and/or hidden areas during clipping of cerebral aneurysms. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Evaluating the utility of 3D TRUS image information in guiding intra-procedure registration for motion compensation

    NASA Astrophysics Data System (ADS)

    De Silva, Tharindu; Cool, Derek W.; Romagnoli, Cesare; Fenster, Aaron; Ward, Aaron D.

    2014-03-01

    In targeted 3D transrectal ultrasound (TRUS)-guided biopsy, patient and prostate movement during the procedure can cause target misalignments that hinder accurate sampling of pre-planned suspicious tissue locations. Multiple solutions have been proposed for motion compensation via registration of intra-procedural TRUS images to a baseline 3D TRUS image acquired at the beginning of the biopsy procedure. While 2D TRUS images are widely used for intra-procedural guidance, some solutions utilize richer intra-procedural images such as bi- or multi-planar TRUS or 3D TRUS, acquired by specialized probes. In this work, we measured the impact of such richer intra-procedural imaging on motion compensation accuracy, to evaluate the tradeoff between cost and complexity of intra-procedural imaging versus improved motion compensation. We acquired baseline and intra-procedural 3D TRUS images from 29 patients at standard sextant-template biopsy locations. We used the planes extracted from the 3D intra-procedural scans to simulate 2D and 3D information available in different clinically relevant scenarios for registration. The registration accuracy was evaluated by calculating the target registration error (TRE) using manually identified homologous fiducial markers (micro-calcifications). Our results indicate that TRE improves gradually when the number of intra-procedural imaging planes used in registration is increased. Full 3D TRUS information helps the registration algorithm to robustly converge to more accurate solutions. These results can also inform the design of a fail-safe workflow during motion compensation in a system using a tracked 2D TRUS probe, by prescribing rotational acquisitions that can be performed quickly and easily by the physician immediately prior to needle targeting.

  9. Reflectance confocal microscopy-guided laser ablation of basal cell carcinomas: initial in vivo results

    NASA Astrophysics Data System (ADS)

    Sierra, Heidy; Cordova, Miguel; Yelamos, Oriol; Chen, Chih-Shan Jason; Rajadhyaksha, Milind

    2017-02-01

    Laser ablation offers a procedure for precise, fast and minimally invasive removal of superficial and early nodular basal cell carcinomas (BCCs). However, the lack of histopathological confirmation has been a limitation toward widespread use in the clinic. A reflectance confocal microscopy (RCM) imaging-guided laser ablation approach offers cellular-level histopathology-like feedback directly on the patient, which may guide and help improve the efficacy of this procedure. We performed an initial study on 44 BCCs on 21 patients in vivo (based in an ex vivo bench-top study reported in our earlier papers), using a pulsed erbium: ytterbium aluminum garnet laser and a contrast agent (aluminum chloride). Initial 10 lesions, the RCM imaging-guided detection of either presence of residual tumor or complete clearance was immediately confirmed with histopathology. Additionally, 34 BCCs on 15 patients were treated with RCM imaging-guided laser ablation, and the clearance of tumor is currently being monitored with follow-up imaging (i. e., no histopathology) at 3, 6 and 18 months. Thus far, the imaging resolution appears to be sufficient and consistent for monitoring efficacy in the wound, both immediately post-ablation and subsequently during recovery. The efficacy appears to be promising. However, further investigation and optimization to image over the entire wound (without missing any areas) need to be investigated.

  10. Toward integrated image guided liver surgery

    NASA Astrophysics Data System (ADS)

    Jarnagin, W. R.; Simpson, Amber L.; Miga, M. I.

    2017-03-01

    While clinical neurosurgery has benefited from the advent of frameless image guidance for over three decades, the translation of image guided technologies to abdominal surgery, and more specifically liver resection, has been far more limited. Fundamentally, the workflow, complexity, and presentation have confounded development. With the first real efforts in translation beginning at the turn of the millennia, the work in developing novel augmented technologies to enhance screening, planning, and surgery has come to realization for the field. In this paper, we will review several examples from our own work that demonstrate the impact of image-guided procedure methods in eight clinical studies that speak to: (1) the accuracy in planning for liver resection, (2) enhanced surgical planning with portal vein embolization impact, (3) linking splenic volume changes to post-hepatectomy complications, (4) enhanced intraoperative localization in surgically occult lesions, (5) validation of deformation correction, and a (6) a novel blinded study focused at the value of deformation correction. All six of these studies were achieved in human systems and show the potential impact image guided methodologies could make on liver tissue resection procedures.

  11. Photoacoustic tomography guided diffuse optical tomography for small-animal model

    NASA Astrophysics Data System (ADS)

    Wang, Yihan; Gao, Feng; Wan, Wenbo; Zhang, Yan; Li, Jiao

    2015-03-01

    Diffuse optical tomography (DOT) is a biomedical imaging technology for noninvasive visualization of spatial variation about the optical properties of tissue, which can be applied to in vivo small-animal disease model. However, traditional DOT suffers low spatial resolution due to tissue scattering. To overcome this intrinsic shortcoming, multi-modal approaches that incorporate DOT with other imaging techniques have been intensively investigated, where a priori information provided by the other modalities is normally used to reasonably regularize the inverse problem of DOT. Nevertheless, these approaches usually consider the anatomical structure, which is different from the optical structure. Photoacoustic tomography (PAT) is an emerging imaging modality that is particularly useful for visualizing lightabsorbing structures embedded in soft tissue with higher spatial resolution compared with pure optical imaging. Thus, we present a PAT-guided DOT approach, to obtain the location a priori information of optical structure provided by PAT first, and then guide DOT to reconstruct the optical parameters quantitatively. The results of reconstruction of phantom experiments demonstrate that both quantification and spatial resolution of DOT could be highly improved by the regularization of feasible-region information provided by PAT.

  12. New procedures to evaluate visually lossless compression for display systems

    NASA Astrophysics Data System (ADS)

    Stolitzka, Dale F.; Schelkens, Peter; Bruylants, Tim

    2017-09-01

    Visually lossless image coding in isochronous display streaming or plesiochronous networks reduces link complexity and power consumption and increases available link bandwidth. A new set of codecs developed within the last four years promise a new level of coding quality, but require new techniques that are sufficiently sensitive to the small artifacts or color variations induced by this new breed of codecs. This paper begins with a summary of the new ISO/IEC 29170-2, a procedure for evaluation of lossless coding and reports the new work by JPEG to extend the procedure in two important ways, for HDR content and for evaluating the differences between still images, panning images and image sequences. ISO/IEC 29170-2 relies on processing test images through a well-defined process chain for subjective, forced-choice psychophysical experiments. The procedure sets an acceptable quality level equal to one just noticeable difference. Traditional image and video coding evaluation techniques, such as, those used for television evaluation have not proven sufficiently sensitive to the small artifacts that may be induced by this breed of codecs. In 2015, JPEG received new requirements to expand evaluation of visually lossless coding for high dynamic range images, slowly moving images, i.e., panning, and image sequences. These requirements are the basis for new amendments of the ISO/IEC 29170-2 procedures described in this paper. These amendments promise to be highly useful for the new content in television and cinema mezzanine networks. The amendments passed the final ballot in April 2017 and are on track to be published in 2018.

  13. A software tool for advanced MRgFUS prostate therapy planning and follow up

    NASA Astrophysics Data System (ADS)

    van Straaten, Dörte; Hoogenboom, Martijn; van Amerongen, Martinus J.; Weiler, Florian; Issawi, Jumana Al; Günther, Matthias; Fütterer, Jurgen; Jenne, Jürgen W.

    2017-03-01

    US guided HIFU/FUS ablation for the therapy of prostate cancer is a clinical established method, while MR guided HIFU/FUS applications for prostate recently started clinical evaluation. Even if MRI examination is an excellent diagnostic tool for prostate cancer, it is a time consuming procedure and not practicable within an MRgFUS therapy session. The aim of our ongoing work is to develop software to support therapy planning and post-therapy follow-up for MRgFUS on localized prostate cancer, based on multi-parametric MR protocols. The clinical workflow of diagnosis, therapy and follow-up of MR guided FUS on prostate cancer was deeply analyzed. Based on this, the image processing workflow was designed and all necessary components, e.g. GUI, viewer, registration tools etc. were defined and implemented. The software bases on MeVisLab with several implemented C++ modules for the image processing tasks. The developed software, called LTC (Local Therapy Control) will register and visualize automatically all images (T1w, T2w, DWI etc.) and ADC or perfusion maps gained from the diagnostic MRI session. This maximum of diagnostic information helps to segment all necessary ROIs, e.g. the tumor, for therapy planning. Final therapy planning will be performed based on these segmentation data in the following MRgFUS therapy session. In addition, the developed software should help to evaluate the therapy success, by synchronization and display of pre-therapeutic, therapy and follow-up image data including the therapy plan and thermal dose information. In this ongoing project, the first stand-alone prototype was completed and will be clinically evaluated.

  14. Development of a Meso-Scale SMA-Based Torsion Actuator for Image-Guided Procedures.

    PubMed

    Sheng, Jun; Gandhi, Dheeraj; Gullapalli, Rao; Simard, J Marc; Desai, Jaydev P

    2017-02-01

    This paper presents the design, modeling, and control of a meso-scale torsion actuator based on shape memory alloy (SMA) for image-guided surgical procedures. Developing a miniature torsion actuator is challenging, but it opens the possibility of significantly enhancing the robot agility and maneuverability. The proposed torsion actuator is bi-directionally actuated by a pair of antagonistic SMA torsion springs through alternate Joule heating and natural cooling. The torsion actuator is integrated into a surgical robot prototype to demonstrate its working performance in the humid environment under C-Arm CT image guidance.

  15. Development of a Meso-Scale SMA-Based Torsion Actuator for Image-Guided Procedures

    PubMed Central

    Sheng, Jun; Gandhi, Dheeraj; Gullapalli, Rao; Simard, J. Marc; Desai, Jaydev P.

    2016-01-01

    This paper presents the design, modeling, and control of a meso-scale torsion actuator based on shape memory alloy (SMA) for image-guided surgical procedures. Developing a miniature torsion actuator is challenging, but it opens the possibility of significantly enhancing the robot agility and maneuverability. The proposed torsion actuator is bi-directionally actuated by a pair of antagonistic SMA torsion springs through alternate Joule heating and natural cooling. The torsion actuator is integrated into a surgical robot prototype to demonstrate its working performance in the humid environment under C-Arm CT image guidance. PMID:28210189

  16. Extracting a Purely Non-rigid Deformation Field of a Single Structure

    NASA Astrophysics Data System (ADS)

    Demirci, Stefanie; Manstad-Hulaas, Frode; Navab, Nassir

    During endovascular aortic repair (EVAR) treatment, the aortic shape is subject to severe deformation that is imposed by medical instruments such as guide wires, catheters, and the stent graft. The problem definition of deformable registration of images covering the entire abdominal region, however, is highly ill-posed. We present a new method for extracting the deformation of an aneurysmatic aorta. The outline of the procedure includes initial rigid alignment of two abdominal scans, segmentation of abdominal vessel trees, and automatic reduction of their centerline structures to one specified region of interest around the aorta. Our non-rigid registration procedure then only computes local non-rigid deformation and leaves out all remaining global rigid transformations. In order to evaluate our method, experiments for the extraction of aortic deformation fields are conducted on 15 patient datasets from endovascular aortic repair (EVAR) treatment. A visual assessment of the registration results were performed by two vascular surgeons and one interventional radiologist who are all experts in EVAR procedures.

  17. Comparative ergonomic workflow and user experience analysis of MRI versus fluoroscopy-guided vascular interventions: an iliac angioplasty exemplar case study.

    PubMed

    Fernández-Gutiérrez, Fabiola; Martínez, Santiago; Rube, Martin A; Cox, Benjamin F; Fatahi, Mahsa; Scott-Brown, Kenneth C; Houston, J Graeme; McLeod, Helen; White, Richard D; French, Karen; Gueorguieva, Mariana; Immel, Erwin; Melzer, Andreas

    2015-10-01

    A methodological framework is introduced to assess and compare a conventional fluoroscopy protocol for peripheral angioplasty with a new magnetic resonant imaging (MRI)-guided protocol. Different scenarios were considered during interventions on a perfused arterial phantom with regard to time-based and cognitive task analysis, user experience and ergonomics. Three clinicians with different expertise performed a total of 43 simulated common iliac angioplasties (9 fluoroscopic, 34 MRI-guided) in two blocks of sessions. Six different configurations for MRI guidance were tested in the first block. Four of them were evaluated in the second block and compared to the fluoroscopy protocol. Relevant stages' durations were collected, and interventions were audio-visually recorded from different perspectives. A cued retrospective protocol analysis (CRPA) was undertaken, including personal interviews. In addition, ergonomic constraints in the MRI suite were evaluated. Significant differences were found when comparing the performance between MRI configurations versus fluoroscopy. Two configurations [with times of 8.56 (0.64) and 9.48 (1.13) min] led to reduce procedure time for MRI guidance, comparable to fluoroscopy [8.49 (0.75) min]. The CRPA pointed out the main influential factors for clinical procedure performance. The ergonomic analysis quantified musculoskeletal risks for interventional radiologists when utilising MRI. Several alternatives were suggested to prevent potential low-back injuries. This work presents a step towards the implementation of efficient operational protocols for MRI-guided procedures based on an integral and multidisciplinary framework, applicable to the assessment of current vascular protocols. The use of first-user perspective raises the possibility of establishing new forms of clinical training and education.

  18. A sampling procedure to guide the collection of narrow-band, high-resolution spatially and spectrally representative reflectance data. [satellite imagery of earth resources

    NASA Technical Reports Server (NTRS)

    Brand, R. R.; Barker, J. L.

    1983-01-01

    A multistage sampling procedure using image processing, geographical information systems, and analytical photogrammetry is presented which can be used to guide the collection of representative, high-resolution spectra and discrete reflectance targets for future satellite sensors. The procedure is general and can be adapted to characterize areas as small as minor watersheds and as large as multistate regions. Beginning with a user-determined study area, successive reductions in size and spectral variation are performed using image analysis techniques on data from the Multispectral Scanner, orbital and simulated Thematic Mapper, low altitude photography synchronized with the simulator, and associated digital data. An integrated image-based geographical information system supports processing requirements.

  19. Performance of magnetic field‐guided navigation system for interventional neurosurgical and cardiac procedures

    PubMed Central

    Chu, James C.H.; Hsi, Wen Chien; Hubbard, Lincoln; Zhang, Yunkai; Bernard, Damian; Reeder, Pamela; Lopes, Demetrius

    2005-01-01

    A hospital‐based magnetic guidance system (MGS) was installed to assist a physician in navigating catheters and guide wires during interventional cardiac and neurosurgical procedures. The objective of this study is to examine the performance of this magnetic field‐guided navigation system. Our results show that the system's radiological imaging components produce images with quality similar to that produced by other modern fluoroscopic devices. The system's magnetic navigation components also deflect the wire and catheter tips toward the intended direction. The physician, however, will have to oversteer the wire or catheter when defining the steering angle during the procedure. The MGS could be clinically useful in device navigation deflection and vessel access. PACS numbers: 07.55.Db, 07.85.‐m PMID:16143799

  20. Multispectral Fluorescence Imaging During Robot-assisted Laparoscopic Sentinel Node Biopsy: A First Step Towards a Fluorescence-based Anatomic Roadmap.

    PubMed

    van den Berg, Nynke S; Buckle, Tessa; KleinJan, Gijs H; van der Poel, Henk G; van Leeuwen, Fijs W B

    2017-07-01

    During (robot-assisted) sentinel node (SN) biopsy procedures, intraoperative fluorescence imaging can be used to enhance radioguided SN excision. For this combined pre- and intraoperative SN identification was realized using the hybrid SN tracer, indocyanine green- 99m Tc-nanocolloid. Combining this dedicated SN tracer with a lymphangiographic tracer such as fluorescein may further enhance the accuracy of SN biopsy. Clinical evaluation of a multispectral fluorescence guided surgery approach using the dedicated SN tracer ICG- 99m Tc-nanocolloid, the lymphangiographic tracer fluorescein, and a commercially available fluorescence laparoscope. Pilot study in ten patients with prostate cancer. Following ICG- 99m Tc-nanocolloid administration and preoperative lymphoscintigraphy and single-photon emission computed tomograpy imaging, the number and location of SNs were determined. Fluorescein was injected intraprostatically immediately after the patient was anesthetized. A multispectral fluorescence laparoscope was used intraoperatively to identify both fluorescent signatures. Multispectral fluorescence imaging during robot-assisted radical prostatectomy with extended pelvic lymph node dissection and SN biopsy. (1) Number and location of preoperatively identified SNs. (2) Number and location of SNs intraoperatively identified via ICG- 99m Tc-nanocolloid imaging. (3) Rate of intraoperative lymphatic duct identification via fluorescein imaging. (4) Tumor status of excised (sentinel) lymph node(s). (5) Postoperative complications and follow-up. Near-infrared fluorescence imaging of ICG- 99m Tc-nanocolloid visualized 85.3% of the SNs. In 8/10 patients, fluorescein imaging allowed bright and accurate identification of lymphatic ducts, although higher background staining and tracer washout were observed. The main limitation is the small patient population. Our findings indicate that a lymphangiographic tracer can provide additional information during SN biopsy based on ICG- 99m Tc-nanocolloid. The study suggests that multispectral fluorescence image-guided surgery is clinically feasible. We evaluated the concept of surgical fluorescence guidance using differently colored dyes that visualize complementary features. In the future this concept may provide better guidance towards diseased tissue while sparing healthy tissue, and could thus improve functional and oncologic outcomes. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  1. Dynamic Stimuli And Active Processing In Human Visual Perception

    NASA Astrophysics Data System (ADS)

    Haber, Ralph N.

    1990-03-01

    Theories of visual perception traditionally have considered a static retinal image to be the starting point for processing; and has considered processing both to be passive and a literal translation of that frozen, two dimensional, pictorial image. This paper considers five problem areas in the analysis of human visually guided locomotion, in which the traditional approach is contrasted to newer ones that utilize dynamic definitions of stimulation, and an active perceiver: (1) differentiation between object motion and self motion, and among the various kinds of self motion (e.g., eyes only, head only, whole body, and their combinations); (2) the sources and contents of visual information that guide movement; (3) the acquisition and performance of perceptual motor skills; (4) the nature of spatial representations, percepts, and the perceived layout of space; and (5) and why the retinal image is a poor starting point for perceptual processing. These newer approaches argue that stimuli must be considered as dynamic: humans process the systematic changes in patterned light when objects move and when they themselves move. Furthermore, the processing of visual stimuli must be active and interactive, so that perceivers can construct panoramic and stable percepts from an interaction of stimulus information and expectancies of what is contained in the visual environment. These developments all suggest a very different approach to the computational analyses of object location and identification, and of the visual guidance of locomotion.

  2. Opening the Blood-Brain Barrier with MR Imaging-guided Focused Ultrasound: Preclinical Testing on a Trans-Human Skull Porcine Model.

    PubMed

    Huang, Yuexi; Alkins, Ryan; Schwartz, Michael L; Hynynen, Kullervo

    2017-01-01

    Purpose To develop and test a protocol in preparation for a clinical trial on opening the blood-brain barrier (BBB) with magnetic resonance (MR) imaging-guided focused ultrasound for the delivery of chemotherapy drugs to brain tumors. Materials and Methods The procedures were approved by the institutional animal care committee. A trans-human skull porcine model was designed for the preclinical testing. Wide craniotomies were applied in 11 pigs (weight, approximately 15 kg). A partial human skull was positioned over the animal's brain. A modified clinical MR imaging-guided focused ultrasound brain system was used with a 3.0-T MR unit. The ultrasound beam was steered during sonications over a 3 × 3 grid at 3-mm spacing. Acoustic power levels of 3-20 W were tested. Bolus injections of microbubbles at 4 μL/kg were tested for each sonication. Levels of BBB opening, hemorrhage, and cavitation signal were measured with MR imaging, histologic examination, and cavitation receivers, respectively. A cavitation safety algorithm was developed on the basis of logistic regression of the measurements and tested to minimize the risk of hemorrhage. Results BBB openings of approximately 1 cm 3 in volume were visualized with gadolinium-enhanced MR imaging after sonication at an acoustic power of approximately 5 W. Gross examination of histologic specimens helped confirm Evans blue (bound to macromolecule albumin) extravasation, and hematoxylin-eosin staining helped detect only scattered extravasation of red blood cells. In cases where cavitation signals were higher than thresholds, sonications were terminated immediately without causing hemorrhage. Conclusion With a trans-human skull porcine model, this study demonstrated BBB opening with a 230-kHz system in preparation for a clinical trial. © RSNA, 2016 Online supplemental material is available for this article.

  3. Multispectral photoacoustic imaging of nerves with a clinical ultrasound system

    NASA Astrophysics Data System (ADS)

    Mari, Jean Martial; West, Simeon; Beard, Paul C.; Desjardins, Adrien E.

    2014-03-01

    Accurate and efficient identification of nerves is of great importance during many ultrasound-guided clinical procedures, including nerve blocks and prostate biopsies. It can be challenging to visualise nerves with conventional ultrasound imaging, however. One of the challenges is that nerves can have very similar appearances to nearby structures such as tendons. Several recent studies have highlighted the potential of near-infrared optical spectroscopy for differentiating nerves and adjacent tissues, as this modality can be sensitive to optical absorption of lipids that are present in intra- and extra-neural adipose tissue and in the myelin sheaths. These studies were limited to point measurements, however. In this pilot study, a custom photoacoustic system with a clinical ultrasound imaging probe was used to acquire multi-spectral photoacoustic images of nerves and tendons from swine ex vivo, across the wavelength range of 1100 to 1300 nm. Photoacoustic images were processed and overlaid in colour onto co-registered conventional ultrasound images that were acquired with the same imaging probe. A pronounced optical absorption peak centred at 1210 nm was observed in the photoacoustic signals obtained from nerves, and it was absent in those obtained from tendons. This absorption peak, which is consistent with the presence of lipids, provides a novel image contrast mechanism to significantly enhance the visualization of nerves. In particular, image contrast for nerves was up to 5.5 times greater with photoacoustic imaging (0.82 +/- 0.15) than with conventional ultrasound imaging (0.148 +/- 0.002), with a maximum contrast of 0.95 +/- 0.02 obtained in photoacoustic mode. This pilot study demonstrates the potential of photoacoustic imaging to improve clinical outcomes in ultrasound-guided interventions in regional anaesthesia and interventional oncology.

  4. How a surgeon becomes superman by visualization of intelligently fused multi-modalities

    NASA Astrophysics Data System (ADS)

    Erat, Okan; Pauly, Olivier; Weidert, Simon; Thaller, Peter; Euler, Ekkehard; Mutschler, Wolf; Navab, Nassir; Fallavollita, Pascal

    2013-03-01

    Motivation: The existing visualization of the Camera augmented mobile C-arm (CamC) system does not have enough cues for depth information and presents the anatomical information in a confusing way to surgeons. Methods: We propose a method that segments anatomical information from X-ray and then augment it on the video images. To provide depth cues, pixels belonging to video images are classified as skin and object classes. The augmentation of anatomical information from X-ray is performed only when pixels have a larger probability of belonging to skin class. Results: We tested our algorithm by displaying the new visualization to 2 expert surgeons and 1 medical student during three surgical workflow sequences of the interlocking of intramedullary nail procedure, namely: skin incision, center punching, and drilling. Via a survey questionnaire, they were asked to assess the new visualization when compared to the current alphablending overlay image displayed by CamC. The participants all agreed (100%) that occlusion and instrument tip position detection were immediately improved with our technique. When asked if our visualization has potential to replace the existing alpha-blending overlay during interlocking procedures, all participants did not hesitate to suggest an immediate integration of the visualization for the correct navigation and guidance of the procedure. Conclusion: Current alpha blending visualizations lack proper depth cues and can be a source of confusion for the surgeons when performing surgery. Our visualization concept shows great potential in alleviating occlusion and facilitating clinician understanding during specific workflow steps of the intramedullary nailing procedure.

  5. Sacroplasty for symptomatic sacral hemangioma: a novel treatment approach. A case report.

    PubMed

    Agarwal, V; Sreedher, G; Weiss, K R; Hughes, M A

    2013-06-01

    Painful vertebral body hemangiomas have been successfully treated with vertebroplasty and kyphoplasty. Sacral hemangiomas are uncommon and as such painful sacral hemangiomas are rare entities. We report what we believe is only the second successful treatment of a painful sacral hemangioma with CT-guided sacroplasty. A 56-year-old woman with a history of right-sided total hip arthroplasty and lipoma excision presented to her orthopedic surgeon with persistent right-sided low back pain which radiated into her buttock and right groin and hindered her ability to walk and perform her activities of daily living. MRIs of the thoracic spine, lumbar spine and pelvis showed numerous lesions with imaging characteristics consistent with multiple hemangiomas including a 2.2×2.1 cm lesion involving the right sacrum adjacent to the right S1 neural foramen. Conservative measures including rest, physical therapy, oral analgesics and right-sided sacroiliac joint steroid injection did not provide significant relief. Given her lack of improvement and the fact that her pain localized to the right sacrum, the patient underwent CT-guided sacroplasty for treatment of a painful right sacral hemangioma. Under CT fluoroscopic guidance, a 10 gauge introducer needle was advanced through the soft tissues of the back to the margin of the lesion. Biopsy was then performed and after appropriate preparation, cement was then introduced through the needle using a separate cement filler cannula. Appropriate filling of the right sacral hemangioma was visualized using intermittent CT fluoroscopy. After injection of approximately 2.5 cc of cement, it was felt that there was near complete filling of the right sacral hemangioma. With satisfactory achievement of cement filling, the procedure was terminated. Pathology from biopsy taken at the time of the procedure was consistent with hemangioma. Image-guided sacroplasty with well-defined endpoints is an effective, minimally invasive and safe procedure. Patients with painful sacral hemangiomas can be treated with this technique with no significant complications.

  6. Sacroplasty for Symptomatic Sacral Hemangioma: A Novel Treatment Approach

    PubMed Central

    Agarwal, V.; Sreedher, G.; Weiss, K.R.; Hughes, M.A.

    2013-01-01

    Summary Painful vertebral body hemangiomas have been successfully treated with vertebroplasty and kyphoplasty. Sacral hemangiomas are uncommon and as such painful sacral hemangiomas are rare entities. We report what we believe is only the second successful treatment of a painful sacral hemangioma with CT-guided sacroplasty. A 56-year-old woman with a history of right-sided total hip arthroplasty and lipoma excision presented to her orthopedic surgeon with persistent right-sided low back pain which radiated into her buttock and right groin and hindered her ability to walk and perform her activities of daily living. MRIs of the thoracic spine, lumbar spine and pelvis showed numerous lesions with imaging characteristics consistent with multiple hemangiomas including a 2.2×2.1 cm lesion involving the right sacrum adjacent to the right S1 neural foramen. Conservative measures including rest, physical therapy, oral analgesics and right-sided sacroiliac joint steroid injection did not provide significant relief. Given her lack of improvement and the fact that her pain localized to the right sacrum, the patient underwent CT-guided sacroplasty for treatment of a painful right sacral hemangioma. Under CT fluoroscopic guidance, a 10 gauge introducer needle was advanced through the soft tissues of the back to the margin of the lesion. Biopsy was then performed and after appropriate preparation, cement was then introduced through the needle using a separate cement filler cannula. Appropriate filling of the right sacral hemangioma was visualized using intermittent CT fluoroscopy. After injection of approximately 2.5 cc of cement, it was felt that there was near complete filling of the right sacral hemangioma. With satisfactory achievement of cement filling, the procedure was terminated. Pathology from biopsy taken at the time of the procedure was consistent with hemangioma. Image-guided sacroplasty with well-defined endpoints is an effective, minimally invasive and safe procedure. Patients with painful sacral hemangiomas can be treated with this technique with no significant complications. PMID:23693051

  7. Dosimetric evaluation of the OneDoseTM MOSFET for measuring kilovoltage imaging dose from image-guided radiotherapy procedures.

    PubMed

    Ding, George X; Coffey, Charles W

    2010-09-01

    The purpose of this study is to investigate the feasibility of using a single-use dosimeter, OneDose MOSFET designed for in vivo patient dosimetry, for measuring the radiation dose from kilovoltage (kV) x rays resulting from image-guided procedures. The OneDose MOSFET dosimeters were precalibrated by the manufacturer using Co-60 beams. Their energy response and characteristics for kV x rays were investigated by using an ionization chamber, in which the air-kerma calibration factors were obtained from an Accredited Dosimetry Calibration Laboratory (ADCL). The dosimetric properties have been tested for typical kV beams used in image-guided radiation therapy (IGRT). The direct dose reading from the OneDose system needs to be multiplied by a correction factor ranging from 0.30 to 0.35 for kilovoltage x rays ranging from 50 to 125 kVp, respectively. In addition to energy response, the OneDose dosimeter has up to a 20% reduced sensitivity for beams (70-125 kVp) incident from the back of the OneDose detector. The uncertainty in measuring dose resulting from a kilovoltage beam used in IGRT is approximately 20%; this uncertainty is mainly due to the sensitivity dependence of the incident beam direction relative to the OneDose detector. The ease of use may allow the dosimeter to be suitable for estimating the dose resulting from image-guided procedures.

  8. Ontology-guided organ detection to retrieve web images of disease manifestation: towards the construction of a consumer-based health image library.

    PubMed

    Chen, Yang; Ren, Xiaofeng; Zhang, Guo-Qiang; Xu, Rong

    2013-01-01

    Visual information is a crucial aspect of medical knowledge. Building a comprehensive medical image base, in the spirit of the Unified Medical Language System (UMLS), would greatly benefit patient education and self-care. However, collection and annotation of such a large-scale image base is challenging. To combine visual object detection techniques with medical ontology to automatically mine web photos and retrieve a large number of disease manifestation images with minimal manual labeling effort. As a proof of concept, we first learnt five organ detectors on three detection scales for eyes, ears, lips, hands, and feet. Given a disease, we used information from the UMLS to select affected body parts, ran the pretrained organ detectors on web images, and combined the detection outputs to retrieve disease images. Compared with a supervised image retrieval approach that requires training images for every disease, our ontology-guided approach exploits shared visual information of body parts across diseases. In retrieving 2220 web images of 32 diseases, we reduced manual labeling effort to 15.6% while improving the average precision by 3.9% from 77.7% to 81.6%. For 40.6% of the diseases, we improved the precision by 10%. The results confirm the concept that the web is a feasible source for automatic disease image retrieval for health image database construction. Our approach requires a small amount of manual effort to collect complex disease images, and to annotate them by standard medical ontology terms.

  9. Artificial ascites and pneumoperitoneum to facilitate thermal ablation of liver tumors: a pictorial essay.

    PubMed

    Bhagavatula, Sharath K; Chick, Jeffrey F B; Chauhan, Nikunj R; Shyn, Paul B

    2017-02-01

    Image-guided percutaneous thermal ablation is increasingly utilized in the treatment of hepatic malignancies. Peripherally located hepatic tumors can be difficult to access or located adjacent to critical structures that can be injured. As a result, ablation of peripheral tumors may be avoided or may be performed too cautiously, leading to inadequate ablation coverage. In these cases, separating the tumor from adjacent critical structures can increase the efficacy and safety of procedures. Artificial ascites and artificial pneumoperitoneum are techniques that utilize fluid and gas, respectively, to insulate critical structures from the thermal ablation zone. Induction of artificial ascites and artificial pneumoperitoneum can enable complete ablation of otherwise inaccessible hepatic tumors, improve tumor visualization, minimize unintended thermal injury to surrounding organs, and reduce post-procedural pain. This pictorial essay illustrates and discusses the proper technique and clinical considerations for successful artificial ascites and pneumoperitoneum creation to facilitate safe peripheral hepatic tumor ablation.

  10. Flat-panel cone-beam CT: a novel imaging technology for image-guided procedures

    NASA Astrophysics Data System (ADS)

    Siewerdsen, Jeffrey H.; Jaffray, David A.; Edmundson, Gregory K.; Sanders, W. P.; Wong, John W.; Martinez, Alvaro A.

    2001-05-01

    The use of flat-panel imagers for cone-beam CT signals the emergence of an attractive technology for volumetric imaging. Recent investigations demonstrate volume images with high spatial resolution and soft-tissue visibility and point to a number of logistical characteristics (e.g., open geometry, volume acquisition in a single rotation about the patient, and separation of the imaging and patient support structures) that are attractive to a broad spectrum of applications. Considering application to image-guided (IG) procedures - specifically IG therapies - this paper examines the performance of flat-panel cone-beam CT in relation to numerous constraints and requirements, including time (i.e., speed of image acquisition), dose, and field-of-view. The imaging and guidance performance of a prototype flat panel cone-beam CT system is investigated through the construction of procedure-specific tasks that test the influence of image artifacts (e.g., x-ray scatter and beam-hardening) and volumetric imaging performance (e.g., 3D spatial resolution, noise, and contrast) - taking two specific examples in IG brachytherapy and IG vertebroplasty. For IG brachytherapy, a procedure-specific task is constructed which tests the performance of flat-panel cone-beam CT in measuring the volumetric distribution of Pd-103 permanent implant seeds in relation to neighboring bone and soft-tissue structures in a pelvis phantom. For IG interventional procedures, a procedure-specific task is constructed in the context of vertebroplasty performed on a cadaverized ovine spine, demonstrating the volumetric image quality in pre-, intra-, and post-therapeutic images of the region of interest and testing the performance of the system in measuring the volumetric distribution of bone cement (PMMA) relative to surrounding spinal anatomy. Each of these tasks highlights numerous promising and challenging aspects of flat-panel cone-beam CT applied to IG procedures.

  11. Virtual bronchoscopic navigation without X-ray fluoroscopy to diagnose peripheral pulmonary lesions: a randomized trial.

    PubMed

    Asano, Fumihiro; Ishida, Takashi; Shinagawa, Naofumi; Sukoh, Noriaki; Anzai, Masaki; Kanazawa, Kenya; Tsuzuku, Akifumi; Morita, Satoshi

    2017-12-11

    Transbronchial biopsy for peripheral pulmonary lesions is generally performed under X-ray fluoroscopy. Virtual bronchoscopic navigation (VBN) is a method in which virtual images of the bronchial route to the lesion are produced based on CT images obtained before VBN, and the bronchoscope is guided using these virtual images, improving the diagnostic yield of peripheral pulmonary lesions. VBN has the possibility of eliminating the need for X-ray fluoroscopy in the bronchoscopic diagnosis of peripheral lesions. To determine whether VBN can be a substitute for X-ray fluoroscopy, a randomized multicenter trial (non-inferiority trial) was performed in VBN and X-ray fluoroscopy (XRF) -assisted groups. The non-inferiority margin in the VBN-assisted group compared with the XRF-assisted group was set at 15%. The subjects consisted of 140 patients with peripheral pulmonary lesions with a mean diameter > 3 cm. In the VBN-assisted group, the bronchoscope was guided to the lesion using a VBN system without X-ray fluoroscopy. In the XRF-assisted group, the same bronchoscope was guided to the lesion under X-ray fluoroscopy. Subsequently, in both groups, the lesion was visualized using endobronchial ultrasonography with a guide sheath (EBUS/GS), and biopsy was performed. In this serial procedure, X-ray fluoroscopy was not used in the VBNA group. The subjects of analysis consisted of 129 patients. The diagnostic yield was 76.9% (50/65) in the VBN-assisted group and 85.9% (55/64) in the XRF-assisted group. The difference in the diagnostic yield between the two groups was -9.0% (95% confidence interval: -22.3% ~ 4.3%). The non-inferiority of the VBN-assisted group could not be confirmed. The rate of visualizing lesions by EBUS was 95.4% (62/65) in the VBN-assisted group and 96.9% (62/64) in the XRF-assisted group, being high in both groups. On EBUS/GS, a bronchoscope and biopsy instruments may be guided to the lesions using VBN without X-ray fluoroscopy, but X-ray fluoroscopy is necessary to improve the accuracy of sample collection from lesions. During transbronchial biopsy for peripheral pulmonary lesions, VBN cannot be a substitute for X-ray fluoroscopy. UMIN-CTR (UMIN000001710); registered 16 February 2009.

  12. In vivo optoacoustic temperature imaging for image-guided cryotherapy of prostate cancer

    NASA Astrophysics Data System (ADS)

    Petrova, E. V.; Brecht, H. P.; Motamedi, M.; Oraevsky, A. A.; Ermilov, S. A.

    2018-03-01

    The objective of this study is to demonstrate in vivo the feasibility of optoacoustic temperature imaging during cryotherapy of prostate cancer. We developed a preclinical prototype optoacoustic temperature imager that included pulsed optical excitation at a wavelength of 805 nm, a modified clinical transrectal ultrasound probe, a parallel data acquisition system, image processing and visualization software. Cryotherapy of a canine prostate was performed in vivo using a commercial clinical system, Cryocare® CS, with an integrated ultrasound imaging. The universal temperature-dependent optoacoustic response of blood was employed to convert reconstructed optoacoustic images to temperature maps. Optoacoustic imaging of temperature during prostate cryotherapy was performed in the longitudinal view over a region of 30 mm (long)  ×  10 mm (deep) that covered the rectum, the Denonvilliers fascia, and the posterior portion of the treated gland. The transrectal optoacoustic images showed high-contrast vascularized regions, which were used for quantitative estimation of local temperature profiles. The constructed temperature maps and their temporal dynamics were consistent with the arrangement of the cryoprobe and readouts of the thermal needle sensors. The temporal profiles of the readouts from the thermal needle sensors and the temporal profile estimated from the normalized optoacoustic intensity of the selected vascularized region showed significant resemblance, except for the initial overshoot, that may be explained as a result of the physiological thermoregulatory compensation. The temperature was mapped with errors not exceeding  ±2 °C (standard deviation) consistent with the clinical requirements for monitoring cryotherapy of the prostate. In vivo results showed that the optoacoustic temperature imaging is a promising non-invasive technique for real-time imaging of tissue temperature during cryotherapy of prostate cancer, which can be combined with transrectal ultrasound—the current standard for guiding clinical cryotherapy procedure.

  13. Blueprint for the Diagnosis of Difficulties with Cardinality.

    ERIC Educational Resources Information Center

    Dunlap, William P.; Brennen, Alison H.

    1981-01-01

    The article describes a diagnostic procedure for assessing children's mental images and knowledge of cardinal numbers, 0 through 9. The diagnostic procedure includes the assessment of a child's visual memory, visual perception, symbol recognition, oral naming of numerals, and symbol-set linkage. (Author/SBH)

  14. Partial report and other sampling procedures overestimate the duration of iconic memory.

    PubMed

    Appelman, I B

    1980-03-01

    In three experiments, subjects estimated the duration of a brief visual image (iconic memory) either directly by adjusting onset of a click to offset of the visual image, or indirectly with a Sperling partial report (sampling) procedure. The results indicated that partial report and other sampling procedures may reflect other brief phenomena along with iconic memory. First, the partial report procedure yields a greater estimate of the duration of iconic memory than the more direct click method. Second, the partial report estimate of the duration of iconic memory is affected if the subject is required to simultaneously retain a list of distractor items (memory load), while the click method estimate of the duration of iconic memory is not affected by a memory load. Finally, another sampling procedure based on visual cuing yields different estimates of the duration of iconic memory depending on how many items are cued. It was concluded that partial report and other sampling procedures overestimate the duration of iconic memory.

  15. 3D surface reconstruction and visualization of the Drosophila wing imaginal disc at cellular resolution

    NASA Astrophysics Data System (ADS)

    Bai, Linge; Widmann, Thomas; Jülicher, Frank; Dahmann, Christian; Breen, David

    2013-01-01

    Quantifying and visualizing the shape of developing biological tissues provide information about the morphogenetic processes in multicellular organisms. The size and shape of biological tissues depend on the number, size, shape, and arrangement of the constituting cells. To better understand the mechanisms that guide tissues into their final shape, it is important to investigate the cellular arrangement within tissues. Here we present a data processing pipeline to generate 3D volumetric surface models of epithelial tissues, as well as geometric descriptions of the tissues' apical cell cross-sections. The data processing pipeline includes image acquisition, editing, processing and analysis, 2D cell mesh generation, 3D contourbased surface reconstruction, cell mesh projection, followed by geometric calculations and color-based visualization of morphological parameters. In their first utilization we have applied these procedures to construct a 3D volumetric surface model at cellular resolution of the wing imaginal disc of Drosophila melanogaster. The ultimate goal of the reported effort is to produce tools for the creation of detailed 3D geometric models of the individual cells in epithelial tissues. To date, 3D volumetric surface models of the whole wing imaginal disc have been created, and the apicolateral cell boundaries have been identified, allowing for the calculation and visualization of cell parameters, e.g. apical cross-sectional area of cells. The calculation and visualization of morphological parameters show position-dependent patterns of cell shape in the wing imaginal disc. Our procedures should offer a general data processing pipeline for the construction of 3D volumetric surface models of a wide variety of epithelial tissues.

  16. Comprehensive approach to image-guided surgery

    NASA Astrophysics Data System (ADS)

    Peters, Terence M.; Comeau, Roch M.; Kasrai, Reza; St. Jean, Philippe; Clonda, Diego; Sinasac, M.; Audette, Michel A.; Fenster, Aaron

    1998-06-01

    Image-guided surgery has evolved over the past 15 years from stereotactic planning, where the surgeon planned approaches to intracranial targets on the basis of 2D images presented on a simple workstation, to the use of sophisticated multi- modality 3D image integration in the operating room, with guidance being provided by mechanically, optically or electro-magnetically tracked probes or microscopes. In addition, sophisticated procedures such as thalamotomies and pallidotomies to relieve the symptoms of Parkinson's disease, are performed with the aid of volumetric atlases integrated with the 3D image data. Operations that are performed stereotactically, that is to say via a small burr- hole in the skull, are able to assume that the information contained in the pre-operative imaging study, accurately represents the brain morphology during the surgical procedure. On the other hand, preforming a procedure via an open craniotomy presents a problem. Not only does tissue shift when the operation begins, even the act of opening the skull can cause significant shift of the brain tissue due to the relief of intra-cranial pressure, or the effect of drugs. Means of tracking and correcting such shifts from an important part of the work in the field of image-guided surgery today. One approach has ben through the development of intra-operative MRI imaging systems. We describe an alternative approach which integrates intra-operative ultrasound with pre-operative MRI to track such changes in tissue morphology.

  17. Quality of life assessment in interventional radiology.

    PubMed

    Monsky, Wayne L; Khorsand, Derek; Nolan, Timothy; Douglas, David; Khanna, Pavan

    2014-03-01

    The aim of this review was to describe quality of life (QoL) questionnaires relevant to interventional radiology. Interventional radiologists perform a large number of palliative procedures. The effect of these therapies on QoL is important. This is particularly true for cancer therapies where procedures with marginal survival benefits may result in tremendous QoL benefits. Image-guided minimally invasive procedures should be compared to invasive procedures, with respect to QoL, as part of comparative effectiveness assessment. A large number of questionnaires have been validated for measurement of overall and disease-specific quality of life. Use of applicable QoL assessments can aid in evaluating clinical outcomes and help to further substantiate the need for minimally invasive image-guided procedures. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  18. Optimizing MR imaging-guided navigation for focused ultrasound interventions in the brain

    NASA Astrophysics Data System (ADS)

    Werner, B.; Martin, E.; Bauer, R.; O'Gorman, R.

    2017-03-01

    MR imaging during transcranial MR imaging-guided Focused Ultrasound surgery (tcMRIgFUS) is challenging due to the complex ultrasound transducer setup and the water bolus used for acoustic coupling. Achievable image quality in the tcMRIgFUS setup using the standard body coil is significantly inferior to current neuroradiologic standards. As a consequence, MR image guidance for precise navigation in functional neurosurgical interventions using tcMRIgFUS is basically limited to the acquisition of MR coordinates of salient landmarks such as the anterior and posterior commissure for aligning a stereotactic atlas. Here, we show how improved MR image quality provided by a custom built MR coil and optimized MR imaging sequences can support imaging-guided navigation for functional tcMRIgFUS neurosurgery by visualizing anatomical landmarks that can be integrated into the navigation process to accommodate for patient specific anatomy.

  19. Visualizing deep neural network by alternately image blurring and deblurring.

    PubMed

    Wang, Feng; Liu, Haijun; Cheng, Jian

    2018-01-01

    Visualization from trained deep neural networks has drawn massive public attention in recent. One of the visualization approaches is to train images maximizing the activation of specific neurons. However, directly maximizing the activation would lead to unrecognizable images, which cannot provide any meaningful information. In this paper, we introduce a simple but effective technique to constrain the optimization route of the visualization. By adding two totally inverse transformations, image blurring and deblurring, to the optimization procedure, recognizable images can be created. Our algorithm is good at extracting the details in the images, which are usually filtered by previous methods in the visualizations. Extensive experiments on AlexNet, VGGNet and GoogLeNet illustrate that we can better understand the neural networks utilizing the knowledge obtained by the visualization. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Intensity-based 2D 3D registration for lead localization in robot guided deep brain stimulation

    NASA Astrophysics Data System (ADS)

    Hunsche, Stefan; Sauner, Dieter; El Majdoub, Faycal; Neudorfer, Clemens; Poggenborg, Jörg; Goßmann, Axel; Maarouf, Mohammad

    2017-03-01

    Intraoperative assessment of lead localization has become a standard procedure during deep brain stimulation surgery in many centers, allowing immediate verification of targeting accuracy and, if necessary, adjustment of the trajectory. The most suitable imaging modality to determine lead positioning, however, remains controversially discussed. Current approaches entail the implementation of computed tomography and magnetic resonance imaging. In the present study, we adopted the technique of intensity-based 2D 3D registration that is commonly employed in stereotactic radiotherapy and spinal surgery. For this purpose, intraoperatively acquired 2D x-ray images were fused with preoperative 3D computed tomography (CT) data to verify lead placement during stereotactic robot assisted surgery. Accuracy of lead localization determined from 2D 3D registration was compared to conventional 3D 3D registration in a subsequent patient study. The mean Euclidian distance of lead coordinates estimated from intensity-based 2D 3D registration versus flat-panel detector CT 3D 3D registration was 0.7 mm  ±  0.2 mm. Maximum values of these distances amounted to 1.2 mm. To further investigate 2D 3D registration a simulation study was conducted, challenging two observers to visually assess artificially generated 2D 3D registration errors. 95% of deviation simulations, which were visually assessed as sufficient, had a registration error below 0.7 mm. In conclusion, 2D 3D intensity-based registration revealed high accuracy and reliability during robot guided stereotactic neurosurgery and holds great potential as a low dose, cost effective means for intraoperative lead localization.

  1. [Contrast-enhanced ultrasound (CEUS) and image fusion for procedures of liver interventions].

    PubMed

    Jung, E M; Clevert, D A

    2018-06-01

    Contrast-enhanced ultrasound (CEUS) is becoming increasingly important for the detection and characterization of malignant liver lesions and allows percutaneous treatment when surgery is not possible. Contrast-enhanced ultrasound image fusion with computed tomography (CT) and magnetic resonance imaging (MRI) opens up further options for the targeted investigation of a modified tumor treatment. Ultrasound image fusion offers the potential for real-time imaging and can be combined with other cross-sectional imaging techniques as well as CEUS. With the implementation of ultrasound contrast agents and image fusion, ultrasound has been improved in the detection and characterization of liver lesions in comparison to other cross-sectional imaging techniques. In addition, this method can also be used for intervention procedures. The success rate of fusion-guided biopsies or CEUS-guided tumor ablation lies between 80 and 100% in the literature. Ultrasound-guided image fusion using CT or MRI data, in combination with CEUS, can facilitate diagnosis and therapy follow-up after liver interventions. In addition to the primary applications of image fusion in the diagnosis and treatment of liver lesions, further useful indications can be integrated into daily work. These include, for example, intraoperative and vascular applications as well applications in other organ systems.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vedantham, Srinivasan; Shrestha, Suman; Karellas, Andrew, E-mail: andrew.karellas@umassmed.edu

    Purpose: High-resolution, photon-counting, energy-resolved detector with fast-framing capability can facilitate simultaneous acquisition of precontrast and postcontrast images for subtraction angiography without pixel registration artifacts and can facilitate high-resolution real-time imaging during image-guided interventions. Hence, this study was conducted to determine the spatial resolution characteristics of a hexagonal pixel array photon-counting cadmium telluride (CdTe) detector. Methods: A 650 μm thick CdTe Schottky photon-counting detector capable of concurrently acquiring up to two energy-windowed images was operated in a single energy-window mode to include photons of 10 keV or higher. The detector had hexagonal pixels with apothem of 30 μm resulting in pixelmore » pitch of 60 and 51.96 μm along the two orthogonal directions. The detector was characterized at IEC-RQA5 spectral conditions. Linear response of the detector was determined over the air kerma rate relevant to image-guided interventional procedures ranging from 1.3 nGy/frame to 91.4 μGy/frame. Presampled modulation transfer was determined using a tungsten edge test device. The edge-spread function and the finely sampled line spread function accounted for hexagonal sampling, from which the presampled modulation transfer function (MTF) was determined. Since detectors with hexagonal pixels require resampling to square pixels for distortion-free display, the optimal square pixel size was determined by minimizing the root-mean-squared-error of the aperture functions for the square and hexagonal pixels up to the Nyquist limit. Results: At Nyquist frequencies of 8.33 and 9.62 cycles/mm along the apothem and orthogonal to the apothem directions, the modulation factors were 0.397 and 0.228, respectively. For the corresponding axis, the limiting resolution defined as 10% MTF occurred at 13.3 and 12 cycles/mm, respectively. Evaluation of the aperture functions yielded an optimal square pixel size of 54 μm. After resampling to 54 μm square pixels using trilinear interpolation, the presampled MTF at Nyquist frequency of 9.26 cycles/mm was 0.29 and 0.24 along the orthogonal directions and the limiting resolution (10% MTF) occurred at approximately 12 cycles/mm. Visual analysis of a bar pattern image showed the ability to resolve close to 12 line-pairs/mm and qualitative evaluation of a neurovascular nitinol-stent showed the ability to visualize its struts at clinically relevant conditions. Conclusions: Hexagonal pixel array photon-counting CdTe detector provides high spatial resolution in single-photon counting mode. After resampling to optimal square pixel size for distortion-free display, the spatial resolution is preserved. The dual-energy capabilities of the detector could allow for artifact-free subtraction angiography and basis material decomposition. The proposed high-resolution photon-counting detector with energy-resolving capability can be of importance for several image-guided interventional procedures as well as for pediatric applications.« less

  3. Reinforcing the role of the conventional C-arm--a novel method for simplified distal interlocking.

    PubMed

    Windolf, Markus; Schroeder, Josh; Fliri, Ladina; Dicht, Benno; Liebergall, Meir; Richards, R Geoff

    2012-01-25

    The common practice for insertion of distal locking screws of intramedullary nails is a freehand technique under fluoroscopic control. The process is technically demanding, time-consuming and afflicted to considerable radiation exposure of the patient and the surgical personnel. A new concept is introduced utilizing information from within conventional radiographic images to help accurately guide the surgeon to place the interlocking bolt into the interlocking hole. The newly developed technique was compared to conventional freehand in an operating room (OR) like setting on human cadaveric lower legs in terms of operating time and radiation exposure. The proposed concept (guided freehand), generally based on the freehand gold standard, additionally guides the surgeon by means of visible landmarks projected into the C-arm image. A computer program plans the correct drilling trajectory by processing the lens-shaped hole projections of the interlocking holes from a single image. Holes can be drilled by visually aligning the drill to the planned trajectory. Besides a conventional C-arm, no additional tracking or navigation equipment is required.Ten fresh frozen human below-knee specimens were instrumented with an Expert Tibial Nail (Synthes GmbH, Switzerland). The implants were distally locked by performing the newly proposed technique as well as the conventional freehand technique on each specimen. An orthopedic resident surgeon inserted four distal screws per procedure. Operating time, number of images and radiation time were recorded and statistically compared between interlocking techniques using non-parametric tests. A 58% reduction in number of taken images per screw was found for the guided freehand technique (7.4 ± 3.4) (mean ± SD) compared to the freehand technique (17.6 ± 10.3) (p < 0.001). Total radiation time (all 4 screws) was 55% lower for the guided freehand technique compared to conventional freehand (p = 0.001). Operating time per screw (from first shot to screw tightened) was on average 22% reduced by guided freehand (p = 0.018). In an experimental setting, the newly developed guided freehand technique for distal interlocking has proven to markedly reduce radiation exposure when compared to the conventional freehand technique. The method utilizes established clinical workflows and does not require cost intensive add-on devices or extensive training. The underlying principle carries potential to assist implant positioning in numerous other applications within orthopedics and trauma from screw insertions to placement of plates, nails or prostheses.

  4. Compiler Optimization Pass Visualization: The Procedural Abstraction Case

    ERIC Educational Resources Information Center

    Schaeckeler, Stefan; Shang, Weijia; Davis, Ruth

    2009-01-01

    There is an active research community concentrating on visualizations of algorithms taught in CS1 and CS2 courses. These visualizations can help students to create concrete visual images of the algorithms and their underlying concepts. Not only "fundamental algorithms" can be visualized, but also algorithms used in compilers. Visualizations that…

  5. Value of artisanal simulators to train veterinary students in performing invasive ultrasound-guided procedures.

    PubMed

    Hage, Maria Cristina F N S; Massaferro, Ana Beatriz; Lopes, Érika Rondon; Beraldo, Carolina Mariano; Daniel, Jéssika

    2016-03-01

    Pericardial effusion can lead to cardiac tamponade, which endangers an animal's life. Ultrasound-guided pericardiocentesis is used to remove abnormal liquid; however, it requires technical expertise. In veterinary medical education, the opportunity to teach this procedure to save lives during emergencies is rare; therefore, simulators are recommended for this practice. The present study aimed to create a model that can be made "at home" at low cost for ultrasound-guided pericardiocentesis training and to gather feedback about this model through questionnaires given to the participants. Eighteen professionals and thirty-six students were introduced to the simulator in pairs. After the simulation training session, participants filled out the questionnaire. Participants considered the model strong in the following areas: visualization of the pericardium, the heart, fluid in the pericardium, and fluid decrease during fictitious pericardiocentesis and its realism. They considered the model weak or moderate in the following areas: visualization of the surrounding tissues, difficulty of pericardial puncture, and visualization of the catheter. The professionals classified the realism of the experimental heart as moderate, whereas the undergraduate students classified it as strong. All participants believed that the experimental model could be useful in preparing for a future real situation. This model fulfills the need for a practical, realistic, and cost-effective model for ultrasound-guided pericardiocentesis training. Copyright © 2016 The American Physiological Society.

  6. Category identification of changed land-use polygons in an integrated image processing/geographic information system

    NASA Technical Reports Server (NTRS)

    Westmoreland, Sally; Stow, Douglas A.

    1992-01-01

    A framework is proposed for analyzing ancillary data and developing procedures for incorporating ancillary data to aid interactive identification of land-use categories in land-use updates. The procedures were developed for use within an integrated image processsing/geographic information systems (GIS) that permits simultaneous display of digital image data with the vector land-use data to be updated. With such systems and procedures, automated techniques are integrated with visual-based manual interpretation to exploit the capabilities of both. The procedural framework developed was applied as part of a case study to update a portion of the land-use layer in a regional scale GIS. About 75 percent of the area in the study site that experienced a change in land use was correctly labeled into 19 categories using the combination of automated and visual interpretation procedures developed in the study.

  7. Image-guided ex-vivo targeting accuracy using a laparoscopic tissue localization system

    NASA Astrophysics Data System (ADS)

    Bieszczad, Jerry; Friets, Eric; Knaus, Darin; Rauth, Thomas; Herline, Alan; Miga, Michael; Galloway, Robert; Kynor, David

    2007-03-01

    In image-guided surgery, discrete fiducials are used to determine a spatial registration between the location of surgical tools in the operating theater and the location of targeted subsurface lesions and critical anatomic features depicted in preoperative tomographic image data. However, the lack of readily localized anatomic landmarks has greatly hindered the use of image-guided surgery in minimally invasive abdominal procedures. To address these needs, we have previously described a laser-based system for localization of internal surface anatomy using conventional laparoscopes. During a procedure, this system generates a digitized, three-dimensional representation of visible anatomic surfaces in the abdominal cavity. This paper presents the results of an experiment utilizing an ex-vivo bovine liver to assess subsurface targeting accuracy achieved using our system. During the experiment, several radiopaque targets were inserted into the liver parenchyma. The location of each target was recorded using an optically-tracked insertion probe. The liver surface was digitized using our system, and registered with the liver surface extracted from post-procedure CT images. This surface-based registration was then used to transform the position of the inserted targets into the CT image volume. The target registration error (TRE) achieved using our surface-based registration (given a suitable registration algorithm initialization) was 2.4 mm +/- 1.0 mm. A comparable TRE (2.6 mm +/- 1.7 mm) was obtained using a registration based on traditional fiducial markers placed on the surface of the same liver. These results indicate the potential of fiducial-free, surface-to-surface registration for image-guided lesion targeting in minimally invasive abdominal surgery.

  8. A needle guidance system for biopsy and therapy using two-dimensional ultrasound

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bluvol, Nathan; Sheikh, Allison; Kornecki, Anat

    2008-02-15

    Image-guided needle biopsies are currently used to provide a definitive diagnosis of breast cancer; however, difficulties in tumor targeting exist as the ultrasound (United States) scan plane and biopsy needle must remain coplanar throughout the procedure to display the actual needle tip position. The additional time associated with aligning and maintaining this coplanar relationship results in increased patient discomfort. Biopsy procedural efficiency is further hindered since needle pathway interpretation is often difficult, especially for needle insertions at large depths that usually require multiple reinsertions. The authors developed a system that would increase the speed and accuracy of current breast biopsymore » procedures using readily available two-dimensional (2D) US technology. This system is composed of a passive articulated mechanical arm that attaches to a 2D US transducer. The arm is connected to a computer through custom electronics and software, which were developed as an interface for tracking the positioning of the mechanical components in real time. The arm couples to the biopsy needle and provides visual guidance for the physician performing the procedure in the form of a real-time projected needle pathway overlay on an US image of the breast. An agar test phantom, with stainless steel targets interspersed randomly throughout, was used to validate needle trajectory positioning accuracy. The biopsy needle was guided by both the software and hardware components to the targets. The phantom, with the needle inserted and device decoupled, was placed in an x-ray stereotactic mammography (SM) machine. The needle trajectory and bead target locations were determined in three dimensions from the SM images. Results indicated a mean needle trajectory accuracy error of 0.75{+-}0.42 mm. This is adequate to sample lesions that are <2 mm in diameter. Chicken tissue test phantoms were used to compare core needle biopsy procedure times between experienced radiologists and inexperienced resident radiologists using free-hand US and the needle guidance system. Cylindrical polyvinyl alcohol cryogel lesions, colored blue, were embedded in chicken tissue. Radiologists identified the lesions, visible as hypoechoic masses in the US images, and performed biopsy using a 14-gauge needle. Procedure times were compared based on experience and the technique performed. Using a pair-wise t test, lower biopsy procedure times were observed when using the guidance system versus the free-hand technique (t=12.59, p<0.001). The authors believe that with this improved biopsy guidance they will be able to reduce the ''false negative'' rate of biopsies, especially in the hands of less experienced physicians.« less

  9. Pseudo colour visualization of fused multispectral laser scattering images for optical diagnosis of rheumatoid arthritis

    NASA Astrophysics Data System (ADS)

    Zabarylo, U.; Minet, O.

    2010-01-01

    Investigations on the application of optical procedures for the diagnosis of rheumatism using scattered light images are only at the beginning both in terms of new image-processing methods and subsequent clinical application. For semi-automatic diagnosis using laser light, the multispectral scattered light images are registered and overlapped to pseudo-coloured images, which depict diagnostically essential contents by visually highlighting pathological changes.

  10. MO-FG-210-02: Implementation of Image-Guided Prostate HDR Brachytherapy Using MR-Ultrasound Fusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Libby, B.

    Ultrasound (US) is one of the most widely used imaging modalities in medical practice. Since US imaging offers real-time imaging capability, it has becomes an excellent option to provide image guidance for brachytherapy (IGBT). (1) The physics and the fundamental principles of US imaging are presented, and the typical steps required to commission an US system for IGBT is provided for illustration. (2) Application of US for prostate HDR brachytherapy, including partial prostate treatments using MR-ultrasound co-registration to enable a focused treatment on the disease within the prostate is also presented. Prostate HDR with US image guidance planning can benefitmore » from real time visualization of the needles, and fusion of the ultrasound images with T2 weighted MR allows the focusing of the treatment to the specific areas of disease within the prostate, so that the entire gland need not be treated. Finally, (3) ultrasound guidance for an eye plaque program is presented. US can be a key component of placement and QA for episcleral plaque brachytherapy for ocular cancer, and the UCLA eye plaque program with US for image guidance is presented to demonstrate the utility of US verification of plaque placement in improving the methods and QA in episcleral plaque brachytherapy. Learning Objectives: To understand the physics of an US system and the necessary aspects of commissioning US for image guided brachytherapy (IGBT). To understand real time planning of prostate HDR using ultrasound, and its application in partial prostate treatments using MR-ultrasound fusion to focus treatment on disease within the prostate. To understand the methods and QA in applying US for localizing the target and the implant during a episcleral plaque brachytherapy procedures.« less

  11. Pre-operative planning and intra-operative guidance in modern neurosurgery: a review of 300 cases.

    PubMed Central

    Wadley, J.; Dorward, N.; Kitchen, N.; Thomas, D.

    1999-01-01

    Operative neurosurgery has recently entered an exciting era of image guided surgery or neuronavigation and application of this novel technology is beginning to have a significant impact in many ways in a variety of intracranial procedures. In order to fully assess the advantages of image guided techniques over conventional planning and surgery in selected cases, detailed prospective evaluation has been carried out during the advanced development of an optically tracked neuronavigation system. Over a 2-year period, 300 operative neurosurgical procedures have been performed with the assistance of interactive image guidance, as well as the development of new software applications and hardware tools. A broad range of intracranial neurosurgical procedures were seen to benefit from image guidance, including 163 craniotomies, 53 interactive stereotactic biopsies, 7 tracked neuroendoscopies and 37 complex skull base procedures. The most common pathological diagnoses were cerebral glioma in 98 cases, meningioma in 64 and metastasis in 23. Detailed analysis of a battery of postoperative questions revealed benefits in operative planning, appreciation of anatomy, lesion location, safety of surgery and greatly enhanced surgical confidence. The authors believe that image guided surgical technology, with new developments such as those described, has a significant role to play in contemporary neurosurgery and its widespread adoption in practice will be realised in the near future. Images Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 PMID:10615186

  12. Image-guided feedback for ophthalmic microsurgery using multimodal intraoperative swept-source spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Li, Jianwei D.; Malone, Joseph D.; El-Haddad, Mohamed T.; Arquitola, Amber M.; Joos, Karen M.; Patel, Shriji N.; Tao, Yuankai K.

    2017-02-01

    Surgical interventions for ocular diseases involve manipulations of semi-transparent structures in the eye, but limited visualization of these tissue layers remains a critical barrier to developing novel surgical techniques and improving clinical outcomes. We addressed limitations in image-guided ophthalmic microsurgery by using microscope-integrated multimodal intraoperative swept-source spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography (iSS-SESLO-OCT). We previously demonstrated in vivo human ophthalmic imaging using SS-SESLO-OCT, which enabled simultaneous acquisition of en face SESLO images with every OCT cross-section. Here, we integrated our new 400 kHz iSS-SESLO-OCT, which used a buffered Axsun 1060 nm swept-source, with a surgical microscope and TrueVision stereoscopic viewing system to provide image-based feedback. In vivo human imaging performance was demonstrated on a healthy volunteer, and simulated surgical maneuvers were performed in ex vivo porcine eyes. Denselysampled static volumes and volumes subsampled at 10 volumes-per-second were used to visualize tissue deformations and surgical dynamics during corneal sweeps, compressions, and dissections, and retinal sweeps, compressions, and elevations. En face SESLO images enabled orientation and co-registration with the widefield surgical microscope view while OCT imaging enabled depth-resolved visualization of surgical instrument positions relative to anatomic structures-of-interest. TrueVision heads-up display allowed for side-by-side viewing of the surgical field with SESLO and OCT previews for real-time feedback, and we demonstrated novel integrated segmentation overlays for augmented-reality surgical guidance. Integration of these complementary imaging modalities may benefit surgical outcomes by enabling real-time intraoperative visualization of surgical plans, instrument positions, tissue deformations, and image-based surrogate biomarkers correlated with completion of surgical goals.

  13. Anesthesiology training using 3D imaging and virtual reality

    NASA Astrophysics Data System (ADS)

    Blezek, Daniel J.; Robb, Richard A.; Camp, Jon J.; Nauss, Lee A.

    1996-04-01

    Current training for regional nerve block procedures by anesthesiology residents requires expert supervision and the use of cadavers; both of which are relatively expensive commodities in today's cost-conscious medical environment. We are developing methods to augment and eventually replace these training procedures with real-time and realistic computer visualizations and manipulations of the anatomical structures involved in anesthesiology procedures, such as nerve plexus injections (e.g., celiac blocks). The initial work is focused on visualizations: both static images and rotational renderings. From the initial results, a coherent paradigm for virtual patient and scene representation will be developed.

  14. Visibility of solid and liquid fiducial markers used for image-guided radiation therapy on optical coherence tomography: an esophageal phantom study (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Jelvehgaran, Pouya; Alderliesten, Tanja; Weda, Jelmer J. A.; de Bruin, Daniel M.; Faber, Dirk J.; Hulshof, Maarten C. C. M.; van Leeuwen, Ton G.; van Herk, Marcel B.; de Boer, Johannes F.

    2017-03-01

    Radiation therapy (RT) is used in operable and inoperable esophageal cancer patients. Endoscopic ultrasound-guided fiducial marker placement allows improved translation of the disease extent on endoscopy to computed tomography (CT) images used for RT planning and enables image-guided RT. However, microscopic tumor extent at the time of RT planning is unknown. Endoscopic optical coherence tomography (OCT) is a high-resolution (10-30µm) imaging modality with the potential for accurately determining the longitudinal disease extent. Visibility of fiducial markers on OCT is crucial for integrating OCT findings with the RT planning CT. We investigated the visibility on OCT (NinePoint Medical, Inc.) of 13 commercially available solid (Visicoil, Gold Anchor, Flexicoil, Polymark, and QLRAD) and liquid (BioXmark, Lipiodol, and Hydrogel) fiducial markers of different diameter. We designed and manufactured a set of dedicated Silicone-based esophageal phantoms to perform imaging in a controlled environment. The esophageal phantoms consist of several layers with different TiO2 concentrations to simulate the scattering properties of a typical healthy human esophagus. Markers were placed at various depths (0.5, 1.1, 2.0, and 3.0mm). OCT imaging allowed detection of all fiducial markers and phantom layers. The signal to background ratio was 6-fold higher for the solid fiducial markers than the liquid fiducial markers, yet OCT was capable of visualizing all 13 fiducial markers at all investigated depths. We conclude that RT fiducial markers can be visualized with OCT. This allows integration of OCT findings with CT for image-guided RT.

  15. Development and validation of a visual grading scale for assessing image quality of AP pelvis radiographic images.

    PubMed

    Mraity, Hussien A A B; England, Andrew; Cassidy, Simon; Eachus, Peter; Dominguez, Alejandro; Hogg, Peter

    2016-01-01

    The aim of this article was to apply psychometric theory to develop and validate a visual grading scale for assessing the visual perception of digital image quality anteroposterior (AP) pelvis. Psychometric theory was used to guide scale development. Seven phantom and seven cadaver images of visually and objectively predetermined quality were used to help assess scale reliability and validity. 151 volunteers scored phantom images, and 184 volunteers scored cadaver images. Factor analysis and Cronbach's alpha were used to assess scale validity and reliability. A 24-item scale was produced. Aggregated mean volunteer scores for each image correlated with the rank order of the visually and objectively predetermined image qualities. Scale items had good interitem correlation (≥0.2) and high factor loadings (≥0.3). Cronbach's alpha (reliability) revealed that the scale has acceptable levels of internal reliability for both phantom and cadaver images (α = 0.8 and 0.9, respectively). Factor analysis suggested that the scale is multidimensional (assessing multiple quality themes). This study represents the first full development and validation of a visual image quality scale using psychometric theory. It is likely that this scale will have clinical, training and research applications. This article presents data to create and validate visual grading scales for radiographic examinations. The visual grading scale, for AP pelvis examinations, can act as a validated tool for future research, teaching and clinical evaluations of image quality.

  16. Development and validation of a visual grading scale for assessing image quality of AP pelvis radiographic images

    PubMed Central

    England, Andrew; Cassidy, Simon; Eachus, Peter; Dominguez, Alejandro; Hogg, Peter

    2016-01-01

    Objective: The aim of this article was to apply psychometric theory to develop and validate a visual grading scale for assessing the visual perception of digital image quality anteroposterior (AP) pelvis. Methods: Psychometric theory was used to guide scale development. Seven phantom and seven cadaver images of visually and objectively predetermined quality were used to help assess scale reliability and validity. 151 volunteers scored phantom images, and 184 volunteers scored cadaver images. Factor analysis and Cronbach's alpha were used to assess scale validity and reliability. Results: A 24-item scale was produced. Aggregated mean volunteer scores for each image correlated with the rank order of the visually and objectively predetermined image qualities. Scale items had good interitem correlation (≥0.2) and high factor loadings (≥0.3). Cronbach's alpha (reliability) revealed that the scale has acceptable levels of internal reliability for both phantom and cadaver images (α = 0.8 and 0.9, respectively). Factor analysis suggested that the scale is multidimensional (assessing multiple quality themes). Conclusion: This study represents the first full development and validation of a visual image quality scale using psychometric theory. It is likely that this scale will have clinical, training and research applications. Advances in knowledge: This article presents data to create and validate visual grading scales for radiographic examinations. The visual grading scale, for AP pelvis examinations, can act as a validated tool for future research, teaching and clinical evaluations of image quality. PMID:26943836

  17. Image-guided scapulothoracic arthroscopy for removing firearm projectiles

    PubMed Central

    Ejnisman, Benno; Andreoli, Carlos Vicente; Carvalho, Cassiano Diniz; Pochini, Alberto De Castro

    2014-01-01

    Scapulothoracic arthroscopy is gaining recognition among arthroscopic procedures as it is considered a relatively low morbidity procedure; also, continuing studies of this technique are making it safer. Scapulothoracic arthroscopy can be used for removal of a foreign body. This case report describes the removal of a firearm projectile using image-guided arthroscopy, highlighting the anatomical aspects and characteristics of the surgical technique. In this case, the patient recovered uneventfully, with complete remission of symptoms in 30 days, returning to his usual activities within 2 months after surgery. PMID:25480137

  18. Videoexoscopic real-time intraoperative navigation for spinal neurosurgery: a novel co-adaptation of two existing technology platforms, technical note.

    PubMed

    Huang, Meng; Barber, Sean Michael; Steele, William James; Boghani, Zain; Desai, Viren Rajendrakumar; Britz, Gavin Wayne; West, George Alexander; Trask, Todd Wilson; Holman, Paul Joseph

    2018-06-01

    Image-guided approaches to spinal instrumentation and interbody fusion have been widely popularized in the last decade [1-5]. Navigated pedicle screws are significantly less likely to breach [2, 3, 5, 6]. Navigation otherwise remains a point reference tool because the projection is off-axis to the surgeon's inline loupe or microscope view. The Synaptive robotic brightmatter drive videoexoscope monitor system represents a new paradigm for off-axis high-definition (HD) surgical visualization. It has many advantages over the traditional microscope and loupes, which have already been demonstrated in a cadaveric study [7]. An auxiliary, but powerful capability of this system is projection of a second, modifiable image in a split-screen configuration. We hypothesized that integration of both Medtronic and Synaptive platforms could permit the visualization of reconstructed navigation and surgical field images simultaneously. By utilizing navigated instruments, this configuration has the ability to support live image-guided surgery or real-time navigation (RTN). Medtronic O-arm/Stealth S7 navigation, MetRx, NavLock, and SureTrak spinal systems were implemented on a prone cadaveric specimen with a stream output to the Synaptive Display. Surgical visualization was provided using a Storz Image S1 platform and camera mounted to the Synaptive robotic brightmatter drive. We were able to successfully technically co-adapt both platforms. A minimally invasive transforaminal lumbar interbody fusion (MIS TLIF) and an open pedicle subtraction osteotomy (PSO) were performed using a navigated high-speed drill under RTN. Disc Shaver and Trials under RTN were implemented on the MIS TLIF. The synergy of Synaptive HD videoexoscope robotic drive and Medtronic Stealth platforms allow for live image-guided surgery or real-time navigation (RTN). Off-axis projection also allows upright neutral cervical spine operative ergonomics for the surgeons and improved surgical team visualization and education compared to traditional means. This technique has the potential to augment existing minimally invasive and open approaches, but will require long-term outcome measurements for efficacy.

  19. Image-guided thoracic surgery in the hybrid operation room.

    PubMed

    Ujiie, Hideki; Effat, Andrew; Yasufuku, Kazuhiro

    2017-01-01

    There has been an increase in the use of image-guided technology to facilitate minimally invasive therapy. The next generation of minimally invasive therapy is focused on advancement and translation of novel image-guided technologies in therapeutic interventions, including surgery, interventional pulmonology, radiation therapy, and interventional laser therapy. To establish the efficacy of different minimally invasive therapies, we have developed a hybrid operating room, known as the guided therapeutics operating room (GTx OR) at the Toronto General Hospital. The GTx OR is equipped with multi-modality image-guidance systems, which features a dual source-dual energy computed tomography (CT) scanner, a robotic cone-beam CT (CBCT)/fluoroscopy, high-performance endobronchial ultrasound system, endoscopic surgery system, near-infrared (NIR) fluorescence imaging system, and navigation tracking systems. The novel multimodality image-guidance systems allow physicians to quickly, and accurately image patients while they are on the operating table. This yield improved outcomes since physicians are able to use image guidance during their procedures, and carry out innovative multi-modality therapeutics. Multiple preclinical translational studies pertaining to innovative minimally invasive technology is being developed in our guided therapeutics laboratory (GTx Lab). The GTx Lab is equipped with similar technology, and multimodality image-guidance systems as the GTx OR, and acts as an appropriate platform for translation of research into human clinical trials. Through the GTx Lab, we are able to perform basic research, such as the development of image-guided technologies, preclinical model testing, as well as preclinical imaging, and then translate that research into the GTx OR. This OR allows for the utilization of new technologies in cancer therapy, including molecular imaging, and other innovative imaging modalities, and therefore enables a better quality of life for patients, both during and after the procedure. In this article, we describe capabilities of the GTx systems, and discuss the first-in-human technologies used, and evaluated in GTx OR.

  20. A Proposed Maneuver to Guide Transseptal Puncture Using Real-Time Three-Dimensional Transesophageal Echocardiography: Pilot Study.

    PubMed

    Mahmoud, Hani M; Al-Ghamdi, Mohammed A; Ghabashi, Abdullah E; Anwar, Ashraf M

    2015-01-01

    Aim of Study. To assess the feasibility of a new proposed maneuver "RATLe-90" using real-time three-dimensional transesophageal echocardiography (RT-3DTEE) for anatomically oriented visualization of the interatrial septum (IAS) in guiding the transseptal puncture TSP. Methods. The study included 20 patients (mean age, 60.2 ± 6.7 years; 60% males) who underwent TSP for different indications. RT-3DTEE was used to guide TSP. The proposed maneuver RATLe-90 (Rotate-Anticlockwise-Tilt-Left-90) was applied in all cases to have the anatomically oriented en face view of the IAS from the right atrial (RA) aspect. Having this anatomically oriented view, we guided the TSP catheter towards the proper puncture site according to the planned procedure. Results. Using the RATLe-90 maneuver, the anatomically oriented en face view of the IAS from the RA was obtained in all patients. We were able to guide the puncture catheter to the proper puncture site on the IAS. The 3D images obtained were clearly understood by both echocardiographers and interventionists. The RATLe-90 maneuver acquisition time was 19.9 ± 1.6 seconds. The time-to-tent was 64.8 ± 16.3 seconds. Less TEE probe manipulations were needed while guiding the TSP. Conclusions. Application of RT3D-TEE during TSP using RATLe-90 maneuver is feasible with shorter fluoroscopy time and minimizing TEE probe manipulations.

  1. MO-FG-210-00: US Guided Systems for Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Ultrasound (US) is one of the most widely used imaging modalities in medical practice. Since US imaging offers real-time imaging capability, it has becomes an excellent option to provide image guidance for brachytherapy (IGBT). (1) The physics and the fundamental principles of US imaging are presented, and the typical steps required to commission an US system for IGBT is provided for illustration. (2) Application of US for prostate HDR brachytherapy, including partial prostate treatments using MR-ultrasound co-registration to enable a focused treatment on the disease within the prostate is also presented. Prostate HDR with US image guidance planning can benefitmore » from real time visualization of the needles, and fusion of the ultrasound images with T2 weighted MR allows the focusing of the treatment to the specific areas of disease within the prostate, so that the entire gland need not be treated. Finally, (3) ultrasound guidance for an eye plaque program is presented. US can be a key component of placement and QA for episcleral plaque brachytherapy for ocular cancer, and the UCLA eye plaque program with US for image guidance is presented to demonstrate the utility of US verification of plaque placement in improving the methods and QA in episcleral plaque brachytherapy. Learning Objectives: To understand the physics of an US system and the necessary aspects of commissioning US for image guided brachytherapy (IGBT). To understand real time planning of prostate HDR using ultrasound, and its application in partial prostate treatments using MR-ultrasound fusion to focus treatment on disease within the prostate. To understand the methods and QA in applying US for localizing the target and the implant during a episcleral plaque brachytherapy procedures.« less

  2. MO-FG-210-03: Intraoperative Ultrasonography-Guided Positioning of Plaque Brachytherapy in the Treatment of Choroidal Melanoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lamb, J.

    2015-06-15

    Ultrasound (US) is one of the most widely used imaging modalities in medical practice. Since US imaging offers real-time imaging capability, it has becomes an excellent option to provide image guidance for brachytherapy (IGBT). (1) The physics and the fundamental principles of US imaging are presented, and the typical steps required to commission an US system for IGBT is provided for illustration. (2) Application of US for prostate HDR brachytherapy, including partial prostate treatments using MR-ultrasound co-registration to enable a focused treatment on the disease within the prostate is also presented. Prostate HDR with US image guidance planning can benefitmore » from real time visualization of the needles, and fusion of the ultrasound images with T2 weighted MR allows the focusing of the treatment to the specific areas of disease within the prostate, so that the entire gland need not be treated. Finally, (3) ultrasound guidance for an eye plaque program is presented. US can be a key component of placement and QA for episcleral plaque brachytherapy for ocular cancer, and the UCLA eye plaque program with US for image guidance is presented to demonstrate the utility of US verification of plaque placement in improving the methods and QA in episcleral plaque brachytherapy. Learning Objectives: To understand the physics of an US system and the necessary aspects of commissioning US for image guided brachytherapy (IGBT). To understand real time planning of prostate HDR using ultrasound, and its application in partial prostate treatments using MR-ultrasound fusion to focus treatment on disease within the prostate. To understand the methods and QA in applying US for localizing the target and the implant during a episcleral plaque brachytherapy procedures.« less

  3. Teaching an Old Client New Tricks - the GloVIS Global Visualization Viewer after 14 Years

    NASA Astrophysics Data System (ADS)

    Meyer, D. J.; Steinwand, D.; Lemig, K.; Davis, B.; Werpy, J.; Quenzer, R.

    2014-12-01

    The US Geological Survey's Global Visualization Viewer (GloVIS) is a web-based, visual search and discovery tool used to access imagery from aircraft and space-based imaging systems. GloVIS was introduced shortly after the launch of Landsat 7 to provide a visual client to select images squired by the Enhanced Thematic Mapper Plus. Since then, it has been expanded to search on other Landsat imagery (Multi-spectral Scanner, Thematic Mapper, Operational Land Imager), imagery from a variety of NASA instruments (Moderate Resolution Imaging Spectroradiometer, Advanced Spaceborne Thermal Emissions and Reflection Radiometer, Advanced Land Imager, Hyperion), along with images from high-resolution airborne photography and special collections representing decades-long observations. GloVIS incorporated a number of features considered novel at its original release, such as rapid visual browse, and the ability to use one type of satellite observation (e.g., vegetation seasonality curves derived from the Advanced Very High Resolution Radiometer) to assist in the selection of another (e.g., Landsat). After 14 years, the GloVIS client has gained a large following, having served millions of images to hundreds of thousands of users, but is due for a major re-design. Described here are a set of guiding principles driving the re-design, the methodology used to understand how users discover and retrieve imagery, and candidate technologies to be leveraged in the re-design. The guiding principles include (1) visual co-discovery - the ability to browse and select imagery from diverse sources simultaneously; (2) user-centric design - understanding user needs prior to design and involving users throughout the design process; (3) adaptability - the use of flexible design to permit rapid incorporation of new capabilities, and (4) interoperability - the use of services, conventions and protocols to permit interaction with external sources of Earth science imagery.

  4. Transvaginal 3D Image-Guided High Intensity Focused Ultrasound Array

    NASA Astrophysics Data System (ADS)

    Held, Robert; Nguyen, Thuc Nghi; Vaezy, Shahram

    2005-03-01

    The goal of this project is to develop a transvaginal image-guided High Intensity Focused Ultrasound (HIFU) device using piezocomposite HIFU array technology, and commercially-available ultrasound imaging. Potential applications include treatment of uterine fibroids and abnormal uterine bleeding. The HIFU transducer was an annular phased array, with a focal length range of 30-60 mm, an elliptically-shaped aperture of 35×60 mm, and an operating frequency of 3 MHz. A pillow-shaped bag with water circulation will be used for coupling the HIFU energy into the tissue. An intra-cavity imaging probe (C9-5, Philips) was integrated with the HIFU array such that the focal axis of the HIFU transducer was within the image plane. The entire device will be covered by a gel-filled condom when inserted in the vaginal cavity. To control it, software packages were developed in the LabView programming environment. An imaging algorithm processed the ultrasound image to remove noise patterns due to the HIFU signal. The device will be equipped with a three-dimensional tracking system, using a six-degrees-of-freedom articulating arm. Necrotic lesions were produced in a tissue-mimicking phantom and a turkey breast sample for all focal lengths. Various HIFU doses allow various necrotic lesion shapes, including thin ellipsoidal, spherical, wide cylindrical, and teardrop-shaped. Software control of the device allows multiple foci to be activated sequentially for desired lesion patterns. Ultrasound imaging synchronization can be achieved using hardware signals obtained from the imaging system, or software signals determined empirically for various imaging probes. The image-guided HIFU device will provide a valuable tool in visualization of uterine fibroid tumors for the purposes of planning and subsequent HIFU treatment of the tumor, all in a 3D environment. The control system allows for various lesions of different shapes to be optimally positioned in the tumor to cover the entire tumor volume. Real-time ultrasound imaging for guidance and monitoring of HIFU treatment provides an effective method for outpatient-based procedures.

  5. Characterization of optically actuated MRI-compatible active needles for medical interventions

    NASA Astrophysics Data System (ADS)

    Black, Richard J.; Ryu, Seokchang; Moslehi, Behzad; Costa, Joannes M.

    2014-03-01

    The development of a Magnetic Resonance Imaging (MRI) compatible optically-actuated active needle for guided percutaneous surgery and biopsy procedures is described. Electrically passive MRI-compatible actuation in the small diameter needle is provided by non-magnetic materials including a shape memory alloy (SMA) subject to precise fiber laser operation that can be from a remote (e.g., MRI control room) location. Characterization and optimization of the needle is facilitated using optical fiber Bragg grating (FBG) temperature sensors arrays. Active bending of the needle during insertion allows the needle to be accurately guided to even relatively small targets in an organ while avoiding obstacles and overcoming undesirable deviations away from the planned path due to unforeseen or unknowable tissue interactions. This feature makes the needle especially suitable for use in image-guided surgical procedures (ranging from MRI to CT and ultrasound) when accurate targeting is imperative for good treatment outcomes. Such interventions include reaching small tumors in biopsies, delineating freezing areas in, for example, cryosurgery and improving the accuracy of seed placement in brachytherapy. Particularly relevant are prostate procedures, which may be subject to pubic arch interference. Combining diagnostic imaging and actuation assisted biopsy into one treatment can obviate the need for a second exam for guided biopsy, shorten overall procedure times (thus increasing operating room efficiencies), address healthcare reimbursement constraints and, most importantly, improve patient comfort and clinical outcomes.

  6. PET/CT-guided interventions: Indications, advantages, disadvantages and the state of the art.

    PubMed

    Cazzato, Roberto Luigi; Garnon, Julien; Shaygi, Behnam; Koch, Guillaume; Tsoumakidou, Georgia; Caudrelier, Jean; Addeo, Pietro; Bachellier, Philippe; Namer, Izzie Jacques; Gangi, Afshin

    2018-02-01

    Positron emission tomography/computed tomography (PET/CT) represents an emerging imaging guidance modality that has been applied to successfully guide percutaneous procedures such as biopsies and tumour ablations. The aim of the present narrative review is to report the indications, advantages and disadvantages of PET/CT-guided procedures in the field of interventional oncology and to briefly describe the experience gained with this new emerging technique while performing biopsies and tumor ablations.

  7. Hybrid Approach for Biliary Interventions Employing MRI-Guided Bile Duct Puncture with Near-Real-Time Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wybranski, Christian, E-mail: Christian.Wybranski@uk-koeln.de; Pech, Maciej; Lux, Anke

    ObjectiveTo assess the feasibility of a hybrid approach employing MRI-guided bile duct (BD) puncture for subsequent fluoroscopy-guided biliary interventions in patients with non-dilated (≤3 mm) or dilated BD (≥3 mm) but unfavorable conditions for ultrasonography (US)-guided BD puncture.MethodsA total of 23 hybrid interventions were performed in 21 patients. Visualization of BD and puncture needles (PN) in the interventional MR images was rated on a 5-point Likert scale by two radiologists. Technical success, planning time, BD puncture time and positioning adjustments of the PN as well as technical success of the biliary intervention and complication rate were recorded.ResultsVisualization even of third-order non-dilated BDmore » and PN was rated excellent by both radiologists with good to excellent interrater agreement. MRI-guided BD puncture was successful in all cases. Planning and BD puncture times were 1:36 ± 2.13 (0:16–11:07) min. and 3:58 ± 2:35 (1:11–9:32) min. Positioning adjustments of the PN was necessary in two patients. Repeated capsular puncture was not necessary in any case. All biliary interventions were completed successfully without major complications.ConclusionA hybrid approach which employs MRI-guided BD puncture for subsequent fluoroscopy-guided biliary intervention is feasible in clinical routine and yields high technical success in patients with non-dilated BD and/or unfavorable conditions for US-guided puncture. Excellent visualization of BD and PN in near-real-time interventional MRI allows successful cannulation of the BD.« less

  8. Review of fluorescence guided surgery visualization and overlay techniques

    PubMed Central

    Elliott, Jonathan T.; Dsouza, Alisha V.; Davis, Scott C.; Olson, Jonathan D.; Paulsen, Keith D.; Roberts, David W.; Pogue, Brian W.

    2015-01-01

    In fluorescence guided surgery, data visualization represents a critical step between signal capture and display needed for clinical decisions informed by that signal. The diversity of methods for displaying surgical images are reviewed, and a particular focus is placed on electronically detected and visualized signals, as required for near-infrared or low concentration tracers. Factors driving the choices such as human perception, the need for rapid decision making in a surgical environment, and biases induced by display choices are outlined. Five practical suggestions are outlined for optimal display orientation, color map, transparency/alpha function, dynamic range compression, and color perception check. PMID:26504628

  9. Efficacy Analysis of a Script-based Guide for EVAR Execution: is it Possible to Reduce Patient Exposure to Contrast, Operative Time and Blood Loss even when Advanced Technologies are not Available?

    PubMed

    Molinari, Giovani José Dal Poggetto; Guillaumon, Ana Terezinha; Dalbem, Andréia Marques de Oliveira

    2015-01-01

    Despite the patient and medical staff exposure to radiation in endovascular aneurysm repair, the benefits of this abdominal aortic aneurysm type of surgical management are justified by minor recovery time and hospitalization, as well as an option for patients not elected to conventional open repair. In this minimally invasive surgical approach, time of procedure and radiation doses can be substantial--and the increasing frequency of these procedures and it's complexity have impelled vascular surgeons to face additional and successive risk to occupational radiation exposure. Meticulous study of the computed tomography angiography during the endovascular aneurysm repair preparation allows reduction of unnecessary radiation exposure, as also reduces consecutive image acquisition and contrast use (that may be related to renal overload in susceptible patients). Some studies have proposed strategies to optimize endovascular intervention to reduce contrast use and X-ray exposure. Although they might prove to be effective, they rely on use of additional specific and advanced equipment, available only in major centers. As an alternative to this expensive and restrict technology, it is presented a simpler technique through image manipulation on software OsiriX, aiming to reduce both exposures. To analyze the efficacy of the adoption of a study protocol and a script-based guide in preparation for endovascular aneurysm repair through verifying its impact over the surgical procedure--as referred to intravascular contrast infuse, effects over renal function, blood loss and operatory time. A longitudinal prospective study from March 2014 through March 2015, where 30 performed endovascular aneurysm repair were compared to a historic control group. The planning for endovascular aneurysm repair through the patient's tomographic image manipulation in the prospective group was performed with OsiriX MD software. A script-based guide upon gathering detailed computed tomography angiography images was elaborated by the author and distributed to the performing surgical team for appreciation, instruction and pre operatory judgment. Based upon the script, the C-arm gantry angle was specifically corrected in each case of endovascular aneurysm repair, for image optimization and aneurysm's neck visualization. Arteriography was performed under digital subtraction angiography after catheters were positioned according to predicted level description in the referred guide. Statistical analysis were performed with a significance level of 5% (P value<0.05). There was a statistically significant relationship between the two studied periods and the variables: contrast volume (284.5 vs. 31.8 mL), operative time (207.5 vs. 140.4 min.) and blood loss (798.1 vs. 204.4 mL), revealing that they are considerably larger in the historical control group than in the script guided current group. There was no difference related to the volume of contrast used in the two groups and the occurrence of renal impairment. In the present paper it was possible to demonstrate the impact of the ability to manipulate digital formats of medical images without the need of sophisticated equipment, in adoption of a guide based on the compilation of informations collected with assistance of an accessible software performed on a personal computer. Although we could not prove relation to occurrence of renal impairment, there were direct results on reduction of intravascular contrast use, even as surgical time and blood loss, compared to a previous historical period.

  10. Pilot Task Profiles, Human Factors, And Image Realism

    NASA Astrophysics Data System (ADS)

    McCormick, Dennis

    1982-06-01

    Computer Image Generation (CIG) visual systems provide real time scenes for state-of-the-art flight training simulators. The visual system reauires a greater understanding of training tasks, human factors, and the concept of image realism to produce an effective and efficient training scene than is required by other types of visual systems. Image realism must be defined in terms of pilot visual information reauirements. Human factors analysis of training and perception is necessary to determine the pilot's information requirements. System analysis then determines how the CIG and display device can best provide essential information to the pilot. This analysis procedure ensures optimum training effectiveness and system performance.

  11. From the RSNA refresher courses: Image-guided thermal therapy of uterine fibroids.

    PubMed

    Tempany, Clare M

    2007-01-01

    One of the most recent additions to the methods for image-guided therapy is magnetic resonance (MR)-guided focused ultrasound. This method represents a unique closed-loop therapy, with planning, guidance, control, and direct feedback (called MR thermometry), which work together to ensure an effective therapy. The focused ultrasound induces focal tissue destruction by thermocoagulation in a noninvasive manner. MR also enables real-time thermometry to be performed during each and every sonication. These characteristics make MR-guided focused ultrasound an exciting new approach for treating fibroids. Fibroids are diagnosed based on findings from the patient's physical examination supplemented by imaging results. MR imaging is preferred to other imaging modalities because it enables the fibroids and the entire pelvis to be fully examined. After individual fibroids are identified and the target area is defined by the radiologist, the target volume is analyzed in a three-dimensional assessment to ensure the patient's safety. The procedure begins with the delivery of low-power sonication, and the power is gradually increased until the therapeutic dose is reached. After the procedure, postcontrast images are acquired; these should demonstrate tissue necrosis. The results of clinical trials have shown that the treatment is safe, effective, and highly acceptable to patients. RSNA, 2007

  12. Guided filtering for solar image/video processing

    NASA Astrophysics Data System (ADS)

    Xu, Long; Yan, Yihua; Cheng, Jun

    2017-06-01

    A new image enhancement algorithm employing guided filtering is proposed in this work for the enhancement of solar images and videos so that users can easily figure out important fine structures embedded in the recorded images/movies for solar observation. The proposed algorithm can efficiently remove image noises, including Gaussian and impulse noises. Meanwhile, it can further highlight fibrous structures on/beyond the solar disk. These fibrous structures can clearly demonstrate the progress of solar flare, prominence coronal mass emission, magnetic field, and so on. The experimental results prove that the proposed algorithm gives significant enhancement of visual quality of solar images beyond original input and several classical image enhancement algorithms, thus facilitating easier determination of interesting solar burst activities from recorded images/movies.

  13. War: Images of America. Social Studies Unit, Secondary Grades 7-12.

    ERIC Educational Resources Information Center

    Franklin, Edward; And Others

    Designed to accompany an audiovisual filmstrip series devoted to presenting a visual history of life in America, this guide helps secondary school teachers supplement social studies materials dealing with wars over the past 200 years. Using authentic visuals including paintings, drawings, engravings, posters, photographs, songsheets, and cartoons,…

  14. Dress: Images of America. Elementary Version.

    ERIC Educational Resources Information Center

    Franklin, Edward; And Others

    Designed to accompany an audiovisual filmstrip series devoted to presenting a visual history of life in America, this guide contains an elementary school (grades 2-6) unit which traces the history of dress in America over the last century. Using authentic visuals including posters, paintings, advertising, documentary photography, movies, cartoons,…

  15. A deflectable guiding catheter for real-time MRI-guided interventions.

    PubMed

    Bell, Jamie A; Saikus, Christina E; Ratnayaka, Kanishka; Wu, Vincent; Sonmez, Merdim; Faranesh, Anthony Z; Colyer, Jessica H; Lederman, Robert J; Kocaturk, Ozgur

    2012-04-01

    To design a deflectable guiding catheter that omits long metallic components yet preserves mechanical properties to facilitate therapeutic interventional MRI procedures. The catheter shaft incorporated Kevlar braiding. A 180° deflection was attained with a 5-cm nitinol slotted tube, a nitinol spring, and a Kevlar pull string. We tested three designs: passive, passive incorporating an inductively coupled coil, and active receiver. We characterized mechanical properties, MRI properties, RF induced heating, and in vivo performance in swine. Torque and tip deflection force were satisfactory. Representative procedures included hepatic and azygos vein access, laser cardiac septostomy, and atrial septal defect crossing. Visualization was best in the active configuration, delineating profile and tip orientation. The passive configuration could be used in tandem with an active guidewire to overcome its limited conspicuity. There was no RF-induced heating in all configurations under expected use conditions in vitro and in vivo. Kevlar and short nitinol component substitutions preserved mechanical properties. The active design offered the best visibility and usability but reintroduced metal conductors. We describe versatile deflectable guiding catheters with a 0.057" lumen for interventional MRI catheterization. Implementations are feasible using active, inductive, and passive visualization strategies to suit application requirements. Copyright © 2011 Wiley Periodicals, Inc.

  16. Recent advances in near-infrared fluorescence-guided imaging surgery using indocyanine green.

    PubMed

    Namikawa, Tsutomu; Sato, Takayuki; Hanazaki, Kazuhiro

    2015-12-01

    Near-infrared (NIR) fluorescence imaging has better tissue penetration, allowing for the effective rejection of excitation light and detection deep inside organs. Indocyanine green (ICG) generates NIR fluorescence after illumination by an NIR ray, enabling real-time intraoperative visualization of superficial lymphatic channels and vessels transcutaneously. The HyperEye Medical System (HEMS) can simultaneously detect NIR rays under room light to provide color imaging, which enables visualization under bright light. Thus, NIR fluorescence imaging using ICG can provide for excellent diagnostic accuracy in detecting sentinel lymph nodes in cancer and microvascular circulation in various ischemic diseases, to assist us with intraoperative decision making. Including HEMS in this system could further improve the sentinel lymph node mapping and intraoperative identification of blood supply in reconstructive organs and ischemic diseases, making it more attractive than conventional imaging. Moreover, the development of new laparoscopic imaging systems equipped with NIR will allow fluorescence-guided surgery in a minimally invasive setting. Future directions, including the conjugation of NIR fluorophores to target specific cancer markers might be realistic technology with diagnostic and therapeutic benefits.

  17. 3D Printed Abdominal Aortic Aneurysm Phantom for Image Guided Surgical Planning with a Patient Specific Fenestrated Endovascular Graft System

    PubMed Central

    Meess, Karen M.; Izzo, Richard L.; Dryjski, Maciej L.; Curl, Richard E.; Harris, Linda M.; Springer, Michael; Siddiqui, Adnan H.; Rudin, Stephen; Ionita, Ciprian N.

    2017-01-01

    Following new trends in precision medicine, Juxatarenal Abdominal Aortic Aneurysm (JAAA) treatment has been enabled by using patient-specific fenestrated endovascular grafts. The X-ray guided procedure requires precise orientation of multiple modular endografts within the arteries confirmed via radiopaque markers. Patient-specific 3D printed phantoms could familiarize physicians with complex procedures and new devices in a risk-free simulation environment to avoid periprocedural complications and improve training. Using the Vascular Modeling Toolkit (VMTK), 3D Data from a CTA imaging of a patient scheduled for Fenestrated EndoVascular Aortic Repair (FEVAR) was segmented to isolate the aortic lumen, thrombus, and calcifications. A stereolithographic mesh (STL) was generated and then modified in Autodesk MeshMixer for fabrication via a Stratasys Eden 260 printer in a flexible photopolymer to simulate arterial compliance. Fluoroscopic guided simulation of the patient-specific FEVAR procedure was performed by interventionists using all demonstration endografts and accessory devices. Analysis compared treatment strategy between the planned procedure, the simulation procedure, and the patient procedure using a derived scoring scheme. Results With training on the patient-specific 3D printed AAA phantom, the clinical team optimized their procedural strategy. Anatomical landmarks and all devices were visible under x-ray during the simulation mimicking the clinical environment. The actual patient procedure went without complications. Conclusions With advances in 3D printing, fabrication of patient specific AAA phantoms is possible. Simulation with 3D printed phantoms shows potential to inform clinical interventional procedures in addition to CTA diagnostic imaging. PMID:28638171

  18. 3D Printed Abdominal Aortic Aneurysm Phantom for Image Guided Surgical Planning with a Patient Specific Fenestrated Endovascular Graft System.

    PubMed

    Meess, Karen M; Izzo, Richard L; Dryjski, Maciej L; Curl, Richard E; Harris, Linda M; Springer, Michael; Siddiqui, Adnan H; Rudin, Stephen; Ionita, Ciprian N

    2017-02-11

    Following new trends in precision medicine, Juxatarenal Abdominal Aortic Aneurysm (JAAA) treatment has been enabled by using patient-specific fenestrated endovascular grafts. The X-ray guided procedure requires precise orientation of multiple modular endografts within the arteries confirmed via radiopaque markers. Patient-specific 3D printed phantoms could familiarize physicians with complex procedures and new devices in a risk-free simulation environment to avoid periprocedural complications and improve training. Using the Vascular Modeling Toolkit (VMTK), 3D Data from a CTA imaging of a patient scheduled for Fenestrated EndoVascular Aortic Repair (FEVAR) was segmented to isolate the aortic lumen, thrombus, and calcifications. A stereolithographic mesh (STL) was generated and then modified in Autodesk MeshMixer for fabrication via a Stratasys Eden 260 printer in a flexible photopolymer to simulate arterial compliance. Fluoroscopic guided simulation of the patient-specific FEVAR procedure was performed by interventionists using all demonstration endografts and accessory devices. Analysis compared treatment strategy between the planned procedure, the simulation procedure, and the patient procedure using a derived scoring scheme. With training on the patient-specific 3D printed AAA phantom, the clinical team optimized their procedural strategy. Anatomical landmarks and all devices were visible under x-ray during the simulation mimicking the clinical environment. The actual patient procedure went without complications. With advances in 3D printing, fabrication of patient specific AAA phantoms is possible. Simulation with 3D printed phantoms shows potential to inform clinical interventional procedures in addition to CTA diagnostic imaging.

  19. 3D printed abdominal aortic aneurysm phantom for image guided surgical planning with a patient specific fenestrated endovascular graft system

    NASA Astrophysics Data System (ADS)

    Meess, Karen M.; Izzo, Richard L.; Dryjski, Maciej L.; Curl, Richard E.; Harris, Linda M.; Springer, Michael; Siddiqui, Adnan H.; Rudin, Stephen; Ionita, Ciprian N.

    2017-03-01

    Following new trends in precision medicine, Juxatarenal Abdominal Aortic Aneurysm (JAAA) treatment has been enabled by using patient-specific fenestrated endovascular grafts. The X-ray guided procedure requires precise orientation of multiple modular endografts within the arteries confirmed via radiopaque markers. Patient-specific 3D printed phantoms could familiarize physicians with complex procedures and new devices in a risk-free simulation environment to avoid periprocedural complications and improve training. Using the Vascular Modeling Toolkit (VMTK), 3D Data from a CTA imaging of a patient scheduled for Fenestrated EndoVascular Aortic Repair (FEVAR) was segmented to isolate the aortic lumen, thrombus, and calcifications. A stereolithographic mesh (STL) was generated and then modified in Autodesk MeshMixer for fabrication via a Stratasys Eden 260 printer in a flexible photopolymer to simulate arterial compliance. Fluoroscopic guided simulation of the patient-specific FEVAR procedure was performed by interventionists using all demonstration endografts and accessory devices. Analysis compared treatment strategy between the planned procedure, the simulation procedure, and the patient procedure using a derived scoring scheme. Results: With training on the patient-specific 3D printed AAA phantom, the clinical team optimized their procedural strategy. Anatomical landmarks and all devices were visible under x-ray during the simulation mimicking the clinical environment. The actual patient procedure went without complications. Conclusions: With advances in 3D printing, fabrication of patient specific AAA phantoms is possible. Simulation with 3D printed phantoms shows potential to inform clinical interventional procedures in addition to CTA diagnostic imaging.

  20. Virtual and augmented medical imaging environments: enabling technology for minimally invasive cardiac interventional guidance.

    PubMed

    Linte, Cristian A; White, James; Eagleson, Roy; Guiraudon, Gérard M; Peters, Terry M

    2010-01-01

    Virtual and augmented reality environments have been adopted in medicine as a means to enhance the clinician's view of the anatomy and facilitate the performance of minimally invasive procedures. Their value is truly appreciated during interventions where the surgeon cannot directly visualize the targets to be treated, such as during cardiac procedures performed on the beating heart. These environments must accurately represent the real surgical field and require seamless integration of pre- and intra-operative imaging, surgical tracking, and visualization technology in a common framework centered around the patient. This review begins with an overview of minimally invasive cardiac interventions, describes the architecture of a typical surgical guidance platform including imaging, tracking, registration and visualization, highlights both clinical and engineering accuracy limitations in cardiac image guidance, and discusses the translation of the work from the laboratory into the operating room together with typically encountered challenges.

  1. Image-guided elbow interventions: a literature review of interventional treatment options

    PubMed Central

    Sorani, Alan

    2016-01-01

    Over the years, a wide range of image-guided interventional therapies have been used in treating different elbow pathologies, many of which are predominantly based on anecdotal and low-level study findings. This article critically assesses the existing literature and discusses the efficacy of the most commonly utilized interventional procedures for elbow pathology. PMID:26206415

  2. Image Guidance Technologies for Interventional Pain Procedures: Ultrasound, Fluoroscopy, and CT.

    PubMed

    Wang, Dajie

    2018-01-26

    Chronic pain is a common medical condition. Patients who suffer uncontrolled chronic pain may require interventions including spinal injections and various nerve blocks. Interventional procedures have evolved and improved over time since epidural injection was first introduced for low back pain and sciatica in 1901. One of the major contributors in the improvement of these interventions is the advancement of imaging guidance technologies. The utilization of image guidance has dramatically improved the accuracy and safety of these interventions. The first image guidance technology adopted by pain specialists was fluoroscopy. This was followed by CT and ultrasound. Fluoroscopy can be used to visualize bony structures of the spine. It is still the most commonly used guidance technology in spinal injections. In the recent years, ultrasound guidance has been increasingly adopted by interventionists to perform various injections. Because its ability to visualize soft tissue, vessels, and nerves, this guidance technology appears to be a better option than fluoroscopy for interventions including SGB and celiac plexus blocks, when visualization of the vessels may prevent intravascular injection. The current evidence indicates the efficacies of these interventions are similar between ultrasound guidance and fluoroscopy guidance for SGB and celiac plexus blocks. For facet injections and interlaminar epidural steroid injections, it is important to visualize bony structures in order to perform these procedures accurately and safely. It is worth noting that facet joint injections can be done under ultrasound guidance with equivalent efficacy to fluoroscopic guidance. However, obese patients may present challenge for ultrasound guidance due to its poor visualization of deep anatomical structures. Regarding transforaminal epidural steroid injections, there are limited evidence to support that ultrasound guidance technology has equivalent efficacy and less complications comparing to fluoroscopy. However, further studies are required to prove the efficacy of ultrasound-guided transforaminal epidural injections. SI joint is unique due to its multiplanar orientation, irregular joint gap, partial ankylosis, and thick dorsal and interosseous ligament. Therefore, it can be difficult to access the joint space with fluoroscopic guidance and ultrasound guidance. CT scan, with its cross-sectional images, can identify posterior joint gap, is most likely the best guidance technology for this intervention. Intercostal nerves lie in the subcostal grove close to the plural space. Significant risk of pneumothorax is associated with intercostal blocks. Ultrasound can provide visualization of ribs and pleura. Therefore, it may improve the accuracy of the injection and reduce the risk of pneumothorax. At present time, most pain specialists are familiar with fluoroscopic guidance techniques, and fluoroscopic machines are readily available in the pain clinics. In the contrast, CT guidance can only be performed in specially equipped facilities. Ultrasound machine is generally portable and inexpensive in comparison to CT scanner and fluoroscopic machine. As pain specialists continue to improve their patient care, ultrasound and CT guidance will undoubtedly be incorporated more into the pain management practice. This review is based on a paucity of clinical evidence to compare these guidance technologies; clearly, more clinical studies is needed to further elucidate the pro and cons of each guidance method for various pain management interventions.

  3. Short-term Clinical Results of Manipulation Under Ultrasound-Guided Brachial Plexus Block in Patients with Idiopathic Frozen Shoulder and Diabetic Secondary Frozen Shoulder.

    PubMed

    Ando, Akira; Hamada, Junichiro; Hagiwara, Yoshihiro; Sekiguchi, Takuya; Koide, Masashi; Itoi, Eiji

    2018-01-01

    This study examined the effectiveness of manipulation under ultrasound-guided brachial plexus block in patients with recalcitrant idiopathic frozen shoulder and diabetic secondary frozen shoulder (diabetic frozen shoulder). Forty-four idiopathic frozen shoulders and 10 diabetic frozen shoulders with failed conservative treatment for at least 3 months were included in this study. The manipulation was performed under ultrasound-guided brachial plexus block and visual analogue scale, range of motion, and Constant scores were measured before manipulation and at the last follow-up examination. No major complications were observed during the procedure. Sufficient improvement was not obtained in two patients during the procedure and to avoid complications, the procedure was discontinued and subsequently arthroscopic capsular release was performed. Visual analogue scale, range of motion towards all directions, and Constant scores were significantly improved after the manipulation in both the idiopathic frozen shoulder and diabetic frozen shoulder groups, however the diabetic group showed inferior results compared with those of the idiopathic group. This manipulation was effective and shortened the duration of symptoms in most of the idiopathic and diabetic frozen shoulders without major complications during the procedure. Diabetic frozen shoulder showed inferior clinical results and difficulty in recovery in range of motion, which indicated that diabetic frozen shoulder should be discussed as a different entity.

  4. Image-guided interventions and computer-integrated therapy: Quo vadis?

    PubMed

    Peters, Terry M; Linte, Cristian A

    2016-10-01

    Significant efforts have been dedicated to minimizing invasiveness associated with surgical interventions, most of which have been possible thanks to the developments in medical imaging, surgical navigation, visualization and display technologies. Image-guided interventions have promised to dramatically change the way therapies are delivered to many organs. However, in spite of the development of many sophisticated technologies over the past two decades, other than some isolated examples of successful implementations, minimally invasive therapy is far from enjoying the wide acceptance once envisioned. This paper provides a large-scale overview of the state-of-the-art developments, identifies several barriers thought to have hampered the wider adoption of image-guided navigation, and suggests areas of research that may potentially advance the field. Copyright © 2016. Published by Elsevier B.V.

  5. DVV: a taxonomy for mixed reality visualization in image guided surgery.

    PubMed

    Kersten-Oertel, Marta; Jannin, Pierre; Collins, D Louis

    2012-02-01

    Mixed reality visualizations are increasingly studied for use in image guided surgery (IGS) systems, yet few mixed reality systems have been introduced for daily use into the operating room (OR). This may be the result of several factors: the systems are developed from a technical perspective, are rarely evaluated in the field, and/or lack consideration of the end user and the constraints of the OR. We introduce the Data, Visualization processing, View (DVV) taxonomy which defines each of the major components required to implement a mixed reality IGS system. We propose that these components be considered and used as validation criteria for introducing a mixed reality IGS system into the OR. A taxonomy of IGS visualization systems is a step toward developing a common language that will help developers and end users discuss and understand the constituents of a mixed reality visualization system, facilitating a greater presence of future systems in the OR. We evaluate the DVV taxonomy based on its goodness of fit and completeness. We demonstrate the utility of the DVV taxonomy by classifying 17 state-of-the-art research papers in the domain of mixed reality visualization IGS systems. Our classification shows that few IGS visualization systems' components have been validated and even fewer are evaluated.

  6. Navigation with Electromagnetic Tracking for Interventional Radiology Procedures

    PubMed Central

    Wood, Bradford J.; Zhang, Hui; Durrani, Amir; Glossop, Neil; Ranjan, Sohan; Lindisch, David; Levy, Eliott; Banovac, Filip; Borgert, Joern; Krueger, Sascha; Kruecker, Jochen; Viswanathan, Anand; Cleary, Kevin

    2008-01-01

    PURPOSE To assess the feasibility of the use of preprocedural imaging for guide wire, catheter, and needle navigation with electromagnetic tracking in phantom and animal models. MATERIALS AND METHODS An image-guided intervention software system was developed based on open-source software components. Catheters, needles, and guide wires were constructed with small position and orientation sensors in the tips. A tetrahedral-shaped weak electromagnetic field generator was placed in proximity to an abdominal vascular phantom or three pigs on the angiography table. Preprocedural computed tomographic (CT) images of the phantom or pig were loaded into custom-developed tracking, registration, navigation, and rendering software. Devices were manipulated within the phantom or pig with guidance from the previously acquired CT scan and simultaneous real-time angiography. Navigation within positron emission tomography (PET) and magnetic resonance (MR) volumetric datasets was also performed. External and endovascular fiducials were used for registration in the phantom, and registration error and tracking error were estimated. RESULTS The CT scan position of the devices within phantoms and pigs was accurately determined during angiography and biopsy procedures, with manageable error for some applications. Preprocedural CT depicted the anatomy in the region of the devices with real-time position updating and minimal registration error and tracking error (<5 mm). PET can also be used with this system to guide percutaneous biopsies to the most metabolically active region of a tumor. CONCLUSIONS Previously acquired CT, MR, or PET data can be accurately codisplayed during procedures with reconstructed imaging based on the position and orientation of catheters, guide wires, or needles. Multimodality interventions are feasible by allowing the real-time updated display of previously acquired functional or morphologic imaging during angiography, biopsy, and ablation. PMID:15802449

  7. Joint detection of anatomical points on surface meshes and color images for visual registration of 3D dental models

    NASA Astrophysics Data System (ADS)

    Destrez, Raphaël.; Albouy-Kissi, Benjamin; Treuillet, Sylvie; Lucas, Yves

    2015-04-01

    Computer aided planning for orthodontic treatment requires knowing occlusion of separately scanned dental casts. A visual guided registration is conducted starting by extracting corresponding features in both photographs and 3D scans. To achieve this, dental neck and occlusion surface are firstly extracted by image segmentation and 3D curvature analysis. Then, an iterative registration process is conducted during which feature positions are refined, guided by previously found anatomic edges. The occlusal edge image detection is improved by an original algorithm which follows Canny's poorly detected edges using a priori knowledge of tooth shapes. Finally, the influence of feature extraction and position optimization is evaluated in terms of the quality of the induced registration. Best combination of feature detection and optimization leads to a positioning average error of 1.10 mm and 2.03°.

  8. Technique development for photoacoustic imaging guided interventions

    NASA Astrophysics Data System (ADS)

    Cheng, Qian; Zhang, Haonan; Yuan, Jie; Feng, Ting; Xu, Guan; Wang, Xueding

    2015-03-01

    Laser-induced thermotherapy (LITT), i.e. tissue destruction induced by a local increase of temperature by means of laser light energy transmission, has been frequently used for minimally invasive treatments of various diseases such as benign thyroid nodules and liver cancer. The emerging photoacoustic (PA) imaging, when integrated with ultrasound (US), could contribute to LITT procedure. PA can enable a good visualization of percutaneous apparatus deep inside tissue and, therefore, can offer accurate guidance of the optical fibers to the target tissue. Our initial experiment demonstrated that, by picking the strong photoacoustic signals generated at the tips of optical fibers as a needle, the trajectory and position of the fibers could be visualized clearly using a commercial available US unit. When working the conventional US Bscan mode, the fibers disappeared when the angle between the fibers and the probe surface was larger than 60 degree; while working on the new PA mode, the fibers could be visualized without any problem even when the angle between the fibers and the probe surface was larger than 75 degree. Moreover, with PA imaging function integrated, the optical fibers positioned into the target tissue, besides delivering optical energy for thermotherapy, can also be used to generate PA signals for on-line evaluation of LITT. Powered by our recently developed PA physio-chemical analysis, PA measurements from the tissue can provide a direct and accurate feedback of the tissue responses to laser ablation, including the changes in not only chemical compositions but also histological microstructures. The initial experiment on the rat liver model has demonstrated the excellent sensitivity of PA imaging to the changes in tissue temperature rise and tissue status (from native to coagulated) when the tissue is treated in vivo with LITT.

  9. Towards real-time remote processing of laparoscopic video

    NASA Astrophysics Data System (ADS)

    Ronaghi, Zahra; Duffy, Edward B.; Kwartowitz, David M.

    2015-03-01

    Laparoscopic surgery is a minimally invasive surgical technique where surgeons insert a small video camera into the patient's body to visualize internal organs and small tools to perform surgical procedures. However, the benefit of small incisions has a drawback of limited visualization of subsurface tissues, which can lead to navigational challenges in the delivering of therapy. Image-guided surgery (IGS) uses images to map subsurface structures and can reduce the limitations of laparoscopic surgery. One particular laparoscopic camera system of interest is the vision system of the daVinci-Si robotic surgical system (Intuitive Surgical, Sunnyvale, CA, USA). The video streams generate approximately 360 megabytes of data per second, demonstrating a trend towards increased data sizes in medicine, primarily due to higher-resolution video cameras and imaging equipment. Processing this data on a bedside PC has become challenging and a high-performance computing (HPC) environment may not always be available at the point of care. To process this data on remote HPC clusters at the typical 30 frames per second (fps) rate, it is required that each 11.9 MB video frame be processed by a server and returned within 1/30th of a second. The ability to acquire, process and visualize data in real-time is essential for performance of complex tasks as well as minimizing risk to the patient. As a result, utilizing high-speed networks to access computing clusters will lead to real-time medical image processing and improve surgical experiences by providing real-time augmented laparoscopic data. We aim to develop a medical video processing system using an OpenFlow software defined network that is capable of connecting to multiple remote medical facilities and HPC servers.

  10. Preoperative magnetic resonance imaging protocol for endoscopic cranial base image-guided surgery.

    PubMed

    Grindle, Christopher R; Curry, Joseph M; Kang, Melissa D; Evans, James J; Rosen, Marc R

    2011-01-01

    Despite the increasing utilization of image-guided surgery, no radiology protocols for obtaining magnetic resonance (MR) imaging of adequate quality are available in the current literature. At our institution, more than 300 endonasal cranial base procedures including pituitary, extended pituitary, and other anterior skullbase procedures have been performed in the past 3 years. To facilitate and optimize preoperative evaluation and assessment, there was a need to develop a magnetic resonance protocol. Retrospective Technical Assessment was performed. Through a collaborative effort between the otolaryngology, neurosurgery, and neuroradiology departments at our institution, a skull base MR image-guided (IGS) protocol was developed with several ends in mind. First, it was necessary to generate diagnostic images useful for the more frequently seen pathologies to improve work flow and limit the expense and inefficiency of case specific MR studies. Second, it was necessary to generate sequences useful for IGS, preferably using sequences that best highlight that lesion. Currently, at our institution, all MR images used for IGS are obtained using this protocol as part of preoperative planning. The protocol that has been developed allows for thin cut precontrast and postcontrast axial cuts that can be used to plan intraoperative image guidance. It also obtains a thin cut T2 axial series that can be compiled separately for intraoperative imaging, or may be fused with computed tomographic images for combined modality. The outlined protocol obtains image sequences effective for diagnostic and operative purposes for image-guided surgery using both T1 and T2 sequences. Copyright © 2011 Elsevier Inc. All rights reserved.

  11. Optimizing modality selection for image-guided procedures: an analysis of the challenges to ultrasound guidance.

    PubMed

    Beland, Michael D; Sternick, Laura A; Baird, Grayson L; Dupuy, Damian E; Cronan, John J; Mayo-Smith, William W

    2016-04-01

    Selection of the most appropriate modality for image guidance is essential for procedural success. We identified specific factors contributing to failure of ultrasound-guided procedures that were subsequently performed using CT guidance. This single-center, retrospective study included 164 patients who underwent a CT-guided biopsy, aspiration/drainage, or ablation after initially having the same procedure attempted unsuccessfully with ultrasound guidance. Review of the procedure images, reports, biopsy results, and clinical follow-up was performed and the reasons for inability to perform the procedure with ultrasound guidance were recorded. Patient cross-sectional area and depth to target were calculated. Differences in area and depth were compared using general linear modeling. Depth as a predictor of an unfavorable body habitus designation was modeled using logistic regression. US guidance was successful in the vast majority of cases (97%). Of the 164 procedures, there were 92 (56%) biopsies, 63 (38%) aspirations/drainages, and 9 (5%) ablations. The most common reason for procedure failure was poor acoustic window (83/164, 51%). Other reasons included target lesion being poorly discerned from adjacent tissue (61/164, 37%), adjacent bowel gas (34/164, 21%), body habitus (27/164, 16%), and gas-containing collection (22/164, 13%). Within the biopsy subgroup, patients for whom body habitus was a limiting factor were found to have on average a larger cross-sectional area and lesion depth relative to patients whose body habitus was not a complicating factor (p < 0.0001 and p = 0.0009). Poor acoustic window was the most common reason for procedural failure with ultrasound guidance. In addition, as lesion depth increased, the odds that body habitus would limit the procedure also increased. If preliminary imaging suggests a limited sonographic window, particularly for deeper lesions, proceeding directly to CT guidance should be considered.

  12. Calibration and evaluation of a magnetically tracked ICE probe for guidance of left atrial ablation therapy

    NASA Astrophysics Data System (ADS)

    Linte, Cristian A.; Rettmann, Maryam E.; Dilger, Ben; Gunawan, Mia S.; Arunachalam, Shivaram P.; Holmes, David R., III; Packer, Douglas L.; Robb, Richard A.

    2012-02-01

    The novel prototype system for advanced visualization for image-guided left atrial ablation therapy developed in our laboratory permits ready integration of multiple imaging modalities, surgical instrument tracking, interventional devices and electro-physiologic data. This technology allows subject-specific procedure planning and guidance using 3D dynamic, patient-specific models of the patient's heart, augmented with real-time intracardiac echocardiography (ICE). In order for the 2D ICE images to provide intuitive visualization for accurate catheter to surgical target navigation, the transducer must be tracked, so that the acquired images can be appropriately presented with respect to the patient-specific anatomy. Here we present the implementation of a previously developed ultrasound calibration technique for a magnetically tracked ICE transducer, along with a series of evaluation methods to ensure accurate imaging and faithful representation of the imaged structures. Using an engineering-designed phantom, target localization accuracy is assessed by comparing known target locations with their transformed locations inferred from the tracked US images. In addition, the 3D volume reconstruction accuracy is also estimated by comparing a truth volume to that reconstructed from sequential 2D US images. Clinically emulating validation studies are conducted using a patient-specific left atrial phantom. Target localization error of clinically-relevant surgical targets represented by nylon fiducials implanted within the endocardial wall of the phantom was assessed. Our studies have demonstrated 2.4 +/- 0.8 mm target localization error in the engineering-designed evaluation phantoms, 94.8 +/- 4.6 % volume reconstruction accuracy, and 3.1 +/- 1.2 mm target localization error in the left atrial-mimicking phantom. These results are consistent with those disseminated in the literature and also with the accuracy constraints imposed by the employed technology and the clinical application.

  13. Delay and Standard Deviation Beamforming to Enhance Specular Reflections in Ultrasound Imaging.

    PubMed

    Bandaru, Raja Sekhar; Sornes, Anders Rasmus; Hermans, Jeroen; Samset, Eigil; D'hooge, Jan

    2016-12-01

    Although interventional devices, such as needles, guide wires, and catheters, are best visualized by X-ray, real-time volumetric echography could offer an attractive alternative as it avoids ionizing radiation; it provides good soft tissue contrast, and it is mobile and relatively cheap. Unfortunately, as echography is traditionally used to image soft tissue and blood flow, the appearance of interventional devices in conventional ultrasound images remains relatively poor, which is a major obstacle toward ultrasound-guided interventions. The objective of this paper was therefore to enhance the appearance of interventional devices in ultrasound images. Thereto, a modified ultrasound beamforming process using conventional-focused transmit beams is proposed that exploits the properties of received signals containing specular reflections (as arising from these devices). This new beamforming approach referred to as delay and standard deviation beamforming (DASD) was quantitatively tested using simulated as well as experimental data using a linear array transducer. Furthermore, the influence of different imaging settings (i.e., transmit focus, imaging depth, and scan angle) on the obtained image contrast was evaluated. The study showed that the image contrast of specular regions improved by 5-30 dB using DASD beamforming compared with traditional delay and sum (DAS) beamforming. The highest gain in contrast was observed when the interventional device was tilted away from being orthogonal to the transmit beam, which is a major limitation in standard DAS imaging. As such, the proposed beamforming methodology can offer an improved visualization of interventional devices in the ultrasound image with potential implications for ultrasound-guided interventions.

  14. Hounsfield unit recovery in clinical cone beam CT images of the thorax acquired for image guided radiation therapy

    NASA Astrophysics Data System (ADS)

    Slot Thing, Rune; Bernchou, Uffe; Mainegra-Hing, Ernesto; Hansen, Olfred; Brink, Carsten

    2016-08-01

    A comprehensive artefact correction method for clinical cone beam CT (CBCT) images acquired for image guided radiation therapy (IGRT) on a commercial system is presented. The method is demonstrated to reduce artefacts and recover CT-like Hounsfield units (HU) in reconstructed CBCT images of five lung cancer patients. Projection image based artefact corrections of image lag, detector scatter, body scatter and beam hardening are described and applied to CBCT images of five lung cancer patients. Image quality is evaluated through visual appearance of the reconstructed images, HU-correspondence with the planning CT images, and total volume HU error. Artefacts are reduced and CT-like HUs are recovered in the artefact corrected CBCT images. Visual inspection confirms that artefacts are indeed suppressed by the proposed method, and the HU root mean square difference between reconstructed CBCTs and the reference CT images are reduced by 31% when using the artefact corrections compared to the standard clinical CBCT reconstruction. A versatile artefact correction method for clinical CBCT images acquired for IGRT has been developed. HU values are recovered in the corrected CBCT images. The proposed method relies on post processing of clinical projection images, and does not require patient specific optimisation. It is thus a powerful tool for image quality improvement of large numbers of CBCT images.

  15. A novel stereotactic frame for real PET-guided biopsies: A preclinical proof-of-concept.

    PubMed

    Cortes-Rodicio, J; Sanchez-Merino, G; Garcia-Fidalgo, M A; Tobalina-Larrea, I

    2017-09-01

    To design, build and test a stereotactic device that allows PET image-guided biopsies to be performed. An initial prototype consisting of four main pieces, one of which contains radioactive markers to make it visible in the PET images, was built using a 3D printer. Once the device is mounted, a spherical coordinate system is built with the entrance needle point in the skin as the origin of coordinates. Two in-house software programs, namely getCoord.ijm, which obtains the spherical coordinates of the tumour tissue to be biopsied, and getNeedle.ijm, which virtualizes the inner needle tip once the puncture has taken place, were written. This prototype was tested on an FDG-doped phantom to characterize both the accuracy of the system and the procedure time. Up to 11 complete biopsy procedures were conducted. The mean total procedure time was less than 20min, which is less than the procedure time of conventional standard CT-guided biopsies. The overall accuracy of the system was found to be 5.0±1.3mm, which outperforms the criterion used in routine clinical practice when targeting tumours with a diameter of 10mm. A stereotactic frame to conduct real PET image-guided biopsies has been designed and built. A proof-of-concept was performed to characterize the system. The procedure time and accuracy of the system were found to meet the current needs of physicians performing biopsies. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  16. Listening to music during transrectal ultrasound-guided prostate biopsy decreases anxiety, pain and dissatisfaction in patients: a pilot randomized controlled trial.

    PubMed

    Chang, Yun Hee; Oh, Tae Hoon; Lee, Jae Whan; Park, Seung Chol; Seo, Ill Young; Jeong, Hee Jong; Kwon, Whi-An

    2015-01-01

    To determine whether listening to music during transrectal ultrasound (TRUS)-guided 12-core needle prostate biopsy decreases anxiety, pain and dissatisfaction among patients and results in a more comfortable and better tolerated procedure. 76 male patients who underwent TRUS-guided prostate biopsy between March 2013 and June 2014 were randomized into the following groups: no music (group I, n = 38) or classical music (group II, n = 38) during the procedure. Before TRUS-guided prostate biopsy, lidocaine gel was instilled into the rectum. Patient anxiety levels were quantified using the State-Trait Anxiety Inventory. A visual analog scale (0-10) was used for self-assessment of satisfaction, discomfort and willingness among patients to have a repeat TRUS-guided prostate biopsy. Demographic characteristics, mean age, procedure duration and procedure indications did not differ statistically between the two groups. The mean anxiety level and mean pain score of group II were significantly lower than those of group I (p = 0.001 and p = 0.003, respectively). Group II also had a significantly higher mean satisfaction score than group I (p = 0.007). Before the procedure, heart rate and systolic blood pressure were similar in groups I and II; however, after the procedure, levels were lower in group II than in group I (heart rate, p = 0.014; systolic blood pressure, p = 0.011). Listening to music during TRUS-guided prostate biopsy significantly reduced patients' feelings of pain, discomfort and dissatisfaction. Music can serve as a simple, inexpensive and effective adjunct to sedation during TRUS-guided prostate biopsy. We recommend playing music during TRUS-guided prostate biopsy. 2014 S. Karger AG, Basel

  17. PLUS: open-source toolkit for ultrasound-guided intervention systems.

    PubMed

    Lasso, Andras; Heffter, Tamas; Rankin, Adam; Pinter, Csaba; Ungi, Tamas; Fichtinger, Gabor

    2014-10-01

    A variety of advanced image analysis methods have been under the development for ultrasound-guided interventions. Unfortunately, the transition from an image analysis algorithm to clinical feasibility trials as part of an intervention system requires integration of many components, such as imaging and tracking devices, data processing algorithms, and visualization software. The objective of our paper is to provide a freely available open-source software platform-PLUS: Public software Library for Ultrasound-to facilitate rapid prototyping of ultrasound-guided intervention systems for translational clinical research. PLUS provides a variety of methods for interventional tool pose and ultrasound image acquisition from a wide range of tracking and imaging devices, spatial and temporal calibration, volume reconstruction, simulated image generation, and recording and live streaming of the acquired data. This paper introduces PLUS, explains its functionality and architecture, and presents typical uses and performance in ultrasound-guided intervention systems. PLUS fulfills the essential requirements for the development of ultrasound-guided intervention systems and it aspires to become a widely used translational research prototyping platform. PLUS is freely available as open source software under BSD license and can be downloaded from http://www.plustoolkit.org.

  18. Multi-focus image fusion using a guided-filter-based difference image.

    PubMed

    Yan, Xiang; Qin, Hanlin; Li, Jia; Zhou, Huixin; Yang, Tingwu

    2016-03-20

    The aim of multi-focus image fusion technology is to integrate different partially focused images into one all-focused image. To realize this goal, a new multi-focus image fusion method based on a guided filter is proposed and an efficient salient feature extraction method is presented in this paper. Furthermore, feature extraction is primarily the main objective of the present work. Based on salient feature extraction, the guided filter is first used to acquire the smoothing image containing the most sharpness regions. To obtain the initial fusion map, we compose a mixed focus measure by combining the variance of image intensities and the energy of the image gradient together. Then, the initial fusion map is further processed by a morphological filter to obtain a good reprocessed fusion map. Lastly, the final fusion map is determined via the reprocessed fusion map and is optimized by a guided filter. Experimental results demonstrate that the proposed method does markedly improve the fusion performance compared to previous fusion methods and can be competitive with or even outperform state-of-the-art fusion methods in terms of both subjective visual effects and objective quality metrics.

  19. Frameless, image-guided stereotactic radiosurgery.

    PubMed

    Steffey-Stacy, Emily Cassandra

    2006-11-01

    To trace the evolution from frame-based to frameless image-guided SRS, to discuss the basic radiobiological principle of fractionation, current clinical trial data, and procedural components of the treatment plan. Nursing and medical literature, neurosurgical textbooks, and select internet sites. The CyberKnife (Accuray, Sunnyvale, CA) is the newest machine added to the technologic armamentarium of patient care. Its capacities are only beginning to be explored and the possibilities are limitless, giving hope to countless persons. Technologic advances have necessitated a diversification of nursing roles. Coordination of patient care services requires nurses to advance their knowledge of frameless, image-guided SRS.

  20. The Use of Laser Guidance Reduces Fluoroscopy Time for C-Arm Cone-Beam Computed Tomography-Guided Biopsies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kroes, Maarten W., E-mail: Maarten.Kroes@radboudumc.nl; Strijen, Marco J. L. van, E-mail: m.van.strijen@antoniusziekenhuis.nl; Braak, Sicco J., E-mail: sjbraak@gmail.com

    2016-09-15

    PurposeWhen using laser guidance for cone-beam computed tomography (CBCT)-guided needle interventions, planned needle paths are visualized to the operator without the need to switch between entry- and progress-view during needle placement. The current study assesses the effect of laser guidance during CBCT-guided biopsies on fluoroscopy and procedure times.Materials and MethodsProspective data from 15 CBCT-guided biopsies of 8–65 mm thoracic and abdominal lesions assisted by a ceiling-mounted laser guidance technique were compared to retrospective data of 36 performed CBCT-guided biopsies of lesions >20 mm using the freehand technique. Fluoroscopy time, procedure time, and number of CBCT-scans were recorded. All data are presented asmore » median (ranges).ResultsFor biopsies using the freehand technique, more fluoroscopy time was necessary to guide the needle onto the target, 165 s (83–333 s) compared to 87 s (44–190 s) for laser guidance (p < 0.001). Procedure times were shorter for freehand-guided biopsies, 24 min versus 30 min for laser guidance (p < 0.001).ConclusionThe use of laser guidance during CBCT-guided biopsies significantly reduces fluoroscopy time.« less

  1. Imaging windows for long-term intravital imaging

    PubMed Central

    Alieva, Maria; Ritsma, Laila; Giedt, Randy J; Weissleder, Ralph; van Rheenen, Jacco

    2014-01-01

    Intravital microscopy is increasingly used to visualize and quantitate dynamic biological processes at the (sub)cellular level in live animals. By visualizing tissues through imaging windows, individual cells (e.g., cancer, host, or stem cells) can be tracked and studied over a time-span of days to months. Several imaging windows have been developed to access tissues including the brain, superficial fascia, mammary glands, liver, kidney, pancreas, and small intestine among others. Here, we review the development of imaging windows and compare the most commonly used long-term imaging windows for cancer biology: the cranial imaging window, the dorsal skin fold chamber, the mammary imaging window, and the abdominal imaging window. Moreover, we provide technical details, considerations, and trouble-shooting tips on the surgical procedures and microscopy setups for each imaging window and explain different strategies to assure imaging of the same area over multiple imaging sessions. This review aims to be a useful resource for establishing the long-term intravital imaging procedure. PMID:28243510

  2. Imaging windows for long-term intravital imaging: General overview and technical insights.

    PubMed

    Alieva, Maria; Ritsma, Laila; Giedt, Randy J; Weissleder, Ralph; van Rheenen, Jacco

    2014-01-01

    Intravital microscopy is increasingly used to visualize and quantitate dynamic biological processes at the (sub)cellular level in live animals. By visualizing tissues through imaging windows, individual cells (e.g., cancer, host, or stem cells) can be tracked and studied over a time-span of days to months. Several imaging windows have been developed to access tissues including the brain, superficial fascia, mammary glands, liver, kidney, pancreas, and small intestine among others. Here, we review the development of imaging windows and compare the most commonly used long-term imaging windows for cancer biology: the cranial imaging window, the dorsal skin fold chamber, the mammary imaging window, and the abdominal imaging window. Moreover, we provide technical details, considerations, and trouble-shooting tips on the surgical procedures and microscopy setups for each imaging window and explain different strategies to assure imaging of the same area over multiple imaging sessions. This review aims to be a useful resource for establishing the long-term intravital imaging procedure.

  3. Optical Flow-Based State Estimation for Guided Projectiles

    DTIC Science & Technology

    2015-06-01

    Computer Vision and Image Understanding. 2012;116(5):606–633. 3. Corke P, Lobo J, Dias J. An introduction to inertial and visual sensing. The...International Journal of Robotics Research. 2007;26(6):519–535. 4. Hutchinson S, Hager GD, Corke PI. A tutorial on visual servo control. Robotics and

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poulou, Loukia S., E-mail: ploukia@hotmail.com; Tsangaridou, Iris; Filippoussis, Petros

    Bronchiolitis obliterans organizing pneumonia (BOOP) is a nonneoplastic, noninfectious lung disease with a diverse spectrum of imaging abnormalities and nonspecific symptoms diagnosed by open lung biopsy, transbroncial biopsy, and/or video-assisted thoracoscopy. The objective of this study was to retrospectively assess the role of percutaneous computed tomography (CT)-guided biopsy in early diagnosis of the disorder. Fourteen BOOP cases diagnosed by CT-guided biopsy were analyzed in terms of imaging abnormalities and complication rate. All had previously undergone a nondiagnostic procedure (bronchoscopy, transbronchial biopsy, bronchoalveolar lavage) to exclude infection or lung cancer. The most common imaging abnormalities in descending order were bilateral consolidationsmore » (5/14), unilateral tumor-like lesions (5/14), unilateral consolidations (3/14), and diffuse reticular pattern (1/14). Coexistent abnormalities (pleural effusions, nodules, ground-glass opacities) were observed in five patients. The complication rate was 4 of 14 (28.6%), including 2 cases of subclinical pneumothorax and 1 case of minor hemoptysis and local lung injury. None required intervention. We conclude that transthoracic CT-guided biopsy may be used in the diagnosis of BOOP in selected patients with mild complications. For the focal consolidation nodule/mass imaging pattern, CT-guided biopsy may prove to be a reasonable alternative to more invasive procedures.« less

  5. Image-guided surgery using near-infrared fluorescent light: from bench to bedside

    NASA Astrophysics Data System (ADS)

    Boogerd, Leonora S. F.; Handgraaf, Henricus J. M.; van de Velde, Cornelis J. H.; Vahrmeijer, Alexander L.

    2015-03-01

    Due to its relatively high tissue penetration, near-infrared (NIR; 700-900 nm) fluorescent light has the potential to visualize structures that need to be resected (e.g. tumors, lymph nodes) and structures that need to be spared (e.g. nerves, ureters, bile ducts). Until now, most clinical trials have focused on suboptimal, non-targeted dyes. Although successful, a new era in image-guided surgery has begun by the introduction of tumor-targeted agents. In this paper, we will describe how tumor-targeted NIR fluorescent imaging can be applied in a clinical setting.

  6. Three-dimensional rotational angiography fused with multimodal imaging modalities for targeted endomyocardial injections in the ischaemic heart.

    PubMed

    Dauwe, Dieter Frans; Nuyens, Dieter; De Buck, Stijn; Claus, Piet; Gheysens, Olivier; Koole, Michel; Coudyzer, Walter; Vanden Driessche, Nina; Janssens, Laurens; Ector, Joris; Dymarkowski, Steven; Bogaert, Jan; Heidbuchel, Hein; Janssens, Stefan

    2014-08-01

    Biological therapies for ischaemic heart disease require efficient, safe, and affordable intramyocardial delivery. Integration of multiple imaging modalities within the fluoroscopy framework can provide valuable information to guide these procedures. We compared an anatomo-electric method (LARCA) with a non-fluoroscopic electromechanical mapping system (NOGA(®)). LARCA integrates selective three-dimensional-rotational angiograms with biplane fluoroscopy. To identify the infarct region, we studied LARCA-fusion with pre-procedural magnetic resonance imaging (MRI), dedicated CT, or (18)F-FDG-PET/CT. We induced myocardial infarction in 20 pigs by 90-min LAD occlusion. Six weeks later, we compared peri-infarct delivery accuracy of coloured fluospheres using sequential NOGA(®)- and LARCA-MRI-guided vs. LARCA-CT- and LARCA-(18)F-FDG-PET/CT-guided intramyocardial injections. MRI after 6 weeks revealed significant left ventricular (LV) functional impairment and remodelling (LVEF 31 ± 3%, LVEDV 178 ± 15 mL, infarct size 17 ± 2% LV mass). During NOGA(®)-procedures, three of five animals required DC-shock for major ventricular arrhythmias vs. one of ten during LARCA-procedures. Online procedure time was shorter for LARCA than NOGA(®) (77 ± 6 vs. 130 ± 3 min, P < 0.0001). Absolute distance of injection spots to the infarct border was similar for LARCA-MRI (4.8 ± 0.5 mm) and NOGA(®) (5.4 ± 0.5 mm). LARCA-CT-integration allowed closer approximation of the targeted border zone than LARCA-PET (4.0 ± 0.5 mm vs. 6.2 ± 0.6 mm, P < 0.05). Three-dimensional -rotational angiography fused with multimodal imaging offers a new, cost-effective, and safe strategy to guide intramyocardial injections. Endoventricular procedure times and arrhythmias compare favourably to NOGA(®), without compromising injection accuracy. LARCA-based fusion imaging is a promising enabling technology for cardiac biological therapies. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  7. 36 CFR 1238.14 - What are the microfilming requirements for permanent and unscheduled records?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... accordance with ISO 18901 (incorporated by reference, see § 1238.5) and use the processing procedures in ANSI... § 1238.5). (2) Background density of images. Agencies must use the background ISO standard visual diffuse... transmission density. (i) Recommended visual diffuse transmission background densities for images of documents...

  8. 36 CFR 1238.14 - What are the microfilming requirements for permanent and unscheduled records?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... accordance with ISO 18901 (incorporated by reference, see § 1238.5) and use the processing procedures in ANSI... § 1238.5). (2) Background density of images. Agencies must use the background ISO standard visual diffuse... transmission density. (i) Recommended visual diffuse transmission background densities for images of documents...

  9. 36 CFR 1238.14 - What are the microfilming requirements for permanent and unscheduled records?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... accordance with ISO 18901 (incorporated by reference, see § 1238.5) and use the processing procedures in ANSI... § 1238.5). (2) Background density of images. Agencies must use the background ISO standard visual diffuse... transmission density. (i) Recommended visual diffuse transmission background densities for images of documents...

  10. Guided SAR image despeckling with probabilistic non local weights

    NASA Astrophysics Data System (ADS)

    Gokul, Jithin; Nair, Madhu S.; Rajan, Jeny

    2017-12-01

    SAR images are generally corrupted by granular disturbances called speckle, which makes visual analysis and detail extraction a difficult task. Non Local despeckling techniques with probabilistic similarity has been a recent trend in SAR despeckling. To achieve effective speckle suppression without compromising detail preservation, we propose an improvement for the existing Generalized Guided Filter with Bayesian Non-Local Means (GGF-BNLM) method. The proposed method (Guided SAR Image Despeckling with Probabilistic Non Local Weights) replaces parametric constants based on heuristics in GGF-BNLM method with dynamically derived values based on the image statistics for weight computation. Proposed changes make GGF-BNLM method adaptive and as a result, significant improvement is achieved in terms of performance. Experimental analysis on SAR images shows excellent speckle reduction without compromising feature preservation when compared to GGF-BNLM method. Results are also compared with other state-of-the-art and classic SAR depseckling techniques to demonstrate the effectiveness of the proposed method.

  11. A novel augmented reality system of image projection for image-guided neurosurgery.

    PubMed

    Mahvash, Mehran; Besharati Tabrizi, Leila

    2013-05-01

    Augmented reality systems combine virtual images with a real environment. To design and develop an augmented reality system for image-guided surgery of brain tumors using image projection. A virtual image was created in two ways: (1) MRI-based 3D model of the head matched with the segmented lesion of a patient using MRIcro software (version 1.4, freeware, Chris Rorden) and (2) Digital photograph based model in which the tumor region was drawn using image-editing software. The real environment was simulated with a head phantom. For direct projection of the virtual image to the head phantom, a commercially available video projector (PicoPix 1020, Philips) was used. The position and size of the virtual image was adjusted manually for registration, which was performed using anatomical landmarks and fiducial markers position. An augmented reality system for image-guided neurosurgery using direct image projection has been designed successfully and implemented in first evaluation with promising results. The virtual image could be projected to the head phantom and was registered manually. Accurate registration (mean projection error: 0.3 mm) was performed using anatomical landmarks and fiducial markers position. The direct projection of a virtual image to the patients head, skull, or brain surface in real time is an augmented reality system that can be used for image-guided neurosurgery. In this paper, the first evaluation of the system is presented. The encouraging first visualization results indicate that the presented augmented reality system might be an important enhancement of image-guided neurosurgery.

  12. Clinical use of organic near-infrared fluorescent contrast agents in image-guided oncologic procedures and its potential in veterinary oncology.

    PubMed

    Favril, Sophie; Abma, Eline; Blasi, Francesco; Stock, Emmelie; Devriendt, Nausikaa; Vanderperren, Katrien; de Rooster, Hilde

    2018-04-28

    One of the major challenges in surgical oncology is the intraoperative discrimination of tumoural versus healthy tissue. Until today, surgeons rely on visual inspection and palpation to define the tumoural margins during surgery and, unfortunately, for various cancer types, the local recurrence rate thus remains unacceptably high. Near-infrared (NIR) fluorescence imaging is an optical imaging technique that can provide real-time preoperative and intraoperative information after administration of a fluorescent probe that emits NIR light once exposed to a NIR light source. This technique is safe, cost-effective and technically easy. Several NIR fluorescent probes are currently studied for their ability to highlight neoplastic cells. In addition, NIR fluorescence imaging holds great promise for sentinel lymph node mapping. The aim of this manuscript is to provide a literature review of the current organic NIR fluorescent probes tested in the light of human oncology and to introduce fluorescence imaging as a valuable asset in veterinary oncology. © British Veterinary Association (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. Platform for intraoperative analysis of video streams

    NASA Astrophysics Data System (ADS)

    Clements, Logan; Galloway, Robert L., Jr.

    2004-05-01

    Interactive, image-guided surgery (IIGS) has proven to increase the specificity of a variety of surgical procedures. However, current IIGS systems do not compensate for changes that occur intraoperatively and are not reflected in preoperative tomograms. Endoscopes and intraoperative ultrasound, used in minimally invasive surgery, provide real-time (RT) information in a surgical setting. Combining the information from RT imaging modalities with traditional IIGS techniques will further increase surgical specificity by providing enhanced anatomical information. In order to merge these techniques and obtain quantitative data from RT imaging modalities, a platform was developed to allow both the display and processing of video streams in RT. Using a Bandit-II CV frame grabber board (Coreco Imaging, St. Laurent, Quebec) and the associated library API, a dynamic link library was created in Microsoft Visual C++ 6.0 such that the platform could be incorporated into the IIGS system developed at Vanderbilt University. Performance characterization, using two relatively inexpensive host computers, has shown the platform capable of performing simple image processing operations on frames captured from a CCD camera and displaying the processed video data at near RT rates both independent of and while running the IIGS system.

  14. Feasibility of real-time MR thermal dose mapping for predicting radiofrequency ablation outcome in the myocardium in vivo.

    PubMed

    Toupin, Solenn; Bour, Pierre; Lepetit-Coiffé, Matthieu; Ozenne, Valéry; Denis de Senneville, Baudouin; Schneider, Rainer; Vaussy, Alexis; Chaumeil, Arnaud; Cochet, Hubert; Sacher, Frédéric; Jaïs, Pierre; Quesson, Bruno

    2017-01-25

    Clinical treatment of cardiac arrhythmia by radiofrequency ablation (RFA) currently lacks quantitative and precise visualization of lesion formation in the myocardium during the procedure. This study aims at evaluating thermal dose (TD) imaging obtained from real-time magnetic resonance (MR) thermometry on the heart as a relevant indicator of the thermal lesion extent. MR temperature mapping based on the Proton Resonance Frequency Shift (PRFS) method was performed at 1.5 T on the heart, with 4 to 5 slices acquired per heartbeat. Respiratory motion was compensated using navigator-based slice tracking. Residual in-plane motion and related magnetic susceptibility artifacts were corrected online. The standard deviation of temperature was measured on healthy volunteers (N = 5) in both ventricles. On animals, the MR-compatible catheter was positioned and visualized in the left ventricle (LV) using a bSSFP pulse sequence with active catheter tracking. Twelve MR-guided RFA were performed on three sheep in vivo at various locations in left ventricle (LV). The dimensions of the thermal lesions measured on thermal dose images, on 3D T1-weighted (T1-w) images acquired immediately after the ablation and at gross pathology were correlated. MR thermometry uncertainty was 1.5 °C on average over more than 96% of the pixels covering the left and right ventricles, on each volunteer. On animals, catheter repositioning in the LV with active slice tracking was successfully performed and each ablation could be monitored in real-time by MR thermometry and thermal dosimetry. Thermal lesion dimensions on TD maps were found to be highly correlated with those observed on post-ablation T1-w images (R = 0.87) that also correlated (R = 0.89) with measurements at gross pathology. Quantitative TD mapping from real-time rapid CMR thermometry during catheter-based RFA is feasible. It provides a direct assessment of the lesion extent in the myocardium with precision in the range of one millimeter. Real-time MR thermometry and thermal dosimetry may improve safety and efficacy of the RFA procedure by offering a reliable indicator of therapy outcome during the procedure.

  15. Sensor fusion for synthetic vision

    NASA Technical Reports Server (NTRS)

    Pavel, M.; Larimer, J.; Ahumada, A.

    1991-01-01

    Display methodologies are explored for fusing images gathered by millimeter wave sensors with images rendered from an on-board terrain data base to facilitate visually guided flight and ground operations in low visibility conditions. An approach to fusion based on multiresolution image representation and processing is described which facilitates fusion of images differing in resolution within and between images. To investigate possible fusion methods, a workstation-based simulation environment is being developed.

  16. Wide-bore 1.5 T MRI-guided deep brain stimulation surgery: initial experience and technique comparison.

    PubMed

    Sillay, Karl A; Rusy, Deborah; Buyan-Dent, Laura; Ninman, Nancy L; Vigen, Karl K

    2014-12-01

    We report results of the initial experience with magnetic resonance image (MRI)-guided implantation of subthalamic nucleus (STN) deep brain stimulating (DBS) electrodes at the University of Wisconsin after having employed frame-based stereotaxy with previously available MR imaging techniques and microelectrode recording for STN DBS surgeries. Ten patients underwent MRI-guided DBS implantation of 20 electrodes between April 2011 and March 2013. The procedure was performed in a purpose-built intraoperative MRI suite configured specifically to allow MRI-guided DBS, using a wide-bore (70 cm) MRI system. Trajectory guidance was accomplished with commercially available system consisting of an MR-visible skull-mounted aiming device and a software guidance system processing intraoperatively acquired iterative MRI scans. A total of 10 patients (5 male, 5 female)-representative of the Parkinson Disease (PD) population-were operated on with standard technique and underwent 20 electrode placements under MRI-guided bilateral STN-targeted DBS placement. All patients completed the procedure with electrodes successfully placed in the STN. Procedure time improved with experience. Our initial experience confirms the safety of MRI-guided DBS, setting the stage for future investigations combining physiology and MRI guidance. Further follow-up is required to compare the efficacy of the MRI-guided surgery cohort to that of traditional frame-based stereotaxy. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. An MR-compatible stereoscopic in-room 3D display for MR-guided interventions.

    PubMed

    Brunner, Alexander; Groebner, Jens; Umathum, Reiner; Maier, Florian; Semmler, Wolfhard; Bock, Michael

    2014-08-01

    A commercial three-dimensional (3D) monitor was modified for use inside the scanner room to provide stereoscopic real-time visualization during magnetic resonance (MR)-guided interventions, and tested in a catheter-tracking phantom experiment at 1.5 T. Brightness, uniformity, radio frequency (RF) emissions and MR image interferences were measured. Due to modifications, the center luminance of the 3D monitor was reduced by 14%, and the addition of a Faraday shield further reduced the remaining luminance by 31%. RF emissions could be effectively shielded; only a minor signal-to-noise ratio (SNR) decrease of 4.6% was observed during imaging. During the tracking experiment, the 3D orientation of the catheter and vessel structures in the phantom could be visualized stereoscopically.

  18. A multimodal image guiding system for Navigated Ultrasound Bronchoscopy (EBUS): A human feasibility study

    PubMed Central

    Hofstad, Erlend Fagertun; Amundsen, Tore; Langø, Thomas; Bakeng, Janne Beate Lervik; Leira, Håkon Olav

    2017-01-01

    Background Endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) is the endoscopic method of choice for confirming lung cancer metastasis to mediastinal lymph nodes. Precision is crucial for correct staging and clinical decision-making. Navigation and multimodal imaging can potentially improve EBUS-TBNA efficiency. Aims To demonstrate the feasibility of a multimodal image guiding system using electromagnetic navigation for ultrasound bronchoschopy in humans. Methods Four patients referred for lung cancer diagnosis and staging with EBUS-TBNA were enrolled in the study. Target lymph nodes were predefined from the preoperative computed tomography (CT) images. A prototype convex probe ultrasound bronchoscope with an attached sensor for position tracking was used for EBUS-TBNA. Electromagnetic tracking of the ultrasound bronchoscope and ultrasound images allowed fusion of preoperative CT and intraoperative ultrasound in the navigation software. Navigated EBUS-TBNA was used to guide target lymph node localization and sampling. Navigation system accuracy was calculated, measured by the deviation between lymph node position in ultrasound and CT in three planes. Procedure time, diagnostic yield and adverse events were recorded. Results Preoperative CT and real-time ultrasound images were successfully fused and displayed in the navigation software during the procedures. Overall navigation accuracy (11 measurements) was 10.0 ± 3.8 mm, maximum 17.6 mm, minimum 4.5 mm. An adequate sample was obtained in 6/6 (100%) of targeted lymph nodes. No adverse events were registered. Conclusions Electromagnetic navigated EBUS-TBNA was feasible, safe and easy in this human pilot study. The clinical usefulness was clearly demonstrated. Fusion of real-time ultrasound, preoperative CT and electromagnetic navigational bronchoscopy provided a controlled guiding to level of target, intraoperative overview and procedure documentation. PMID:28182758

  19. Asymmetric bias in user guided segmentations of brain structures

    NASA Astrophysics Data System (ADS)

    Styner, Martin; Smith, Rachel G.; Graves, Michael M.; Mosconi, Matthew W.; Peterson, Sarah; White, Scott; Blocher, Joe; El-Sayed, Mohammed; Hazlett, Heather C.

    2007-03-01

    Brain morphometric studies often incorporate comparative asymmetry analyses of left and right hemispheric brain structures. In this work we show evidence that common methods of user guided structural segmentation exhibit strong left-right asymmetric biases and thus fundamentally influence any left-right asymmetry analyses. We studied several structural segmentation methods with varying degree of user interaction from pure manual outlining to nearly fully automatic procedures. The methods were applied to MR images and their corresponding left-right mirrored images from an adult and a pediatric study. Several expert raters performed the segmentations of all structures. The asymmetric segmentation bias is assessed by comparing the left-right volumetric asymmetry in the original and mirrored datasets, as well as by testing each sides volumetric differences to a zero mean standard t-tests. The structural segmentations of caudate, putamen, globus pallidus, amygdala and hippocampus showed a highly significant asymmetric bias using methods with considerable manual outlining or landmark placement. Only the lateral ventricle segmentation revealed no asymmetric bias due to the high degree of automation and a high intensity contrast on its boundary. Our segmentation methods have been adapted in that they are applied to only one of the hemispheres in an image and its left-right mirrored image. Our work suggests that existing studies of hemispheric asymmetry without similar precautions should be interpreted in a new, skeptical light. Evidence of an asymmetric segmentation bias is novel and unknown to the imaging community. This result seems less surprising to the visual perception community and its likely cause is differences in perception of oppositely curved 3D structures.

  20. CT-guided sternoclavicular joint injections: description of the procedure, reliability of imaging diagnosis, and short-term patient responses.

    PubMed

    Peterson, Cynthia K; Saupe, Nadja; Buck, Florian; Pfirrmann, Christian W A; Zanetti, Marco; Hodler, Juerg

    2010-12-01

    The purpose of this study was to evaluate pain relief 20 to 30 minutes after diagnostic or therapeutic injections into the sternoclavicular joint and to compare patient outcomes based on the CT diagnosis. Informed consent was obtained from each patient. Ethics approval was not required. Fifty patients who had CT-guided injections of corticosteroid and local anesthetic into their sternoclavicular joints were included in the study. Preinjection and 20- to 30-minute postinjection visual analog scale data were recorded and compared with the imaging findings agreed by consensus. Kappa statistics were calculated for the reliability of imaging diagnosis. The percentage of patients improving after joint injection was calculated, and the risk ratio comparing the response of patients with osteoarthritis to those without osteoarthritis was completed. The correlation between the severity of each patient's osteoarthritis and the pain response was calculated using Spearman's correlation coefficient. Sixty-six percent of the patients reported clinically significant pain reduction at between 20 and 30 minutes after injection. The proportion of patients with osteoarthritis who had a clinically significant response was 67% compared with 64% for patients who did not have osteoarthritis. This difference was not statistically or clinically significant. There was no correlation between the severity of osteoarthritis and the amount of pain reduction (r = 0.03). The reliability of imaging diagnosis was substantial. Two thirds of patients having sternoclavicular joint injections of corticosteroids and local anesthetics report clinically significant improvement regardless of the abnormalities detected on their CT images.

  1. In-plane ultrasonic needle tracking using a fiber-optic hydrophone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xia, Wenfeng, E-mail: wenfeng.xia@ucl.ac.uk; Desjardins, Adrien E.; Mari, Jean Martial

    Purpose: Accurate and efficient guidance of needles to procedural targets is critically important during percutaneous interventional procedures. Ultrasound imaging is widely used for real-time image guidance in a variety of clinical contexts, but with this modality, uncertainties about the location of the needle tip within the image plane lead to significant complications. Whilst several methods have been proposed to improve the visibility of the needle, achieving accuracy and compatibility with current clinical practice is an ongoing challenge. In this paper, the authors present a method for directly visualizing the needle tip using an integrated fiber-optic ultrasound receiver in conjunction withmore » the imaging probe used to acquire B-mode ultrasound images. Methods: Needle visualization and ultrasound imaging were performed with a clinical ultrasound imaging system. A miniature fiber-optic ultrasound hydrophone was integrated into a 20 gauge injection needle tip to receive transmissions from individual transducer elements of the ultrasound imaging probe. The received signals were reconstructed to create an image of the needle tip. Ultrasound B-mode imaging was interleaved with needle tip imaging. A first set of measurements was acquired in water and tissue ex vivo with a wide range of insertion angles (15°–68°) to study the accuracy and sensitivity of the tracking method. A second set was acquired in an in vivo swine model, with needle insertions to the brachial plexus. A third set was acquired in an in vivo ovine model for fetal interventions, with insertions to different locations within the uterine cavity. Two linear ultrasound imaging probes were used: a 14–5 MHz probe for the first and second sets, and a 9–4 MHz probe for the third. Results: During insertions in tissue ex vivo and in vivo, the imaged needle tip had submillimeter axial and lateral dimensions. The signal-to-noise (SNR) of the needle tip was found to depend on the insertion angle. With the needle tip in water, the SNR of the needle tip varied with insertion angle, attaining values of 284 at 27° and 501 at 68°. In swine tissue ex vivo, the SNR decreased from 80 at 15° to 16 at 61°. In swine tissue in vivo, the SNR varied with depth, from 200 at 17.5 mm to 48 at 26 mm, with a constant insertion angle of 40°. In ovine tissue in vivo, within the uterine cavity, the SNR varied from 46.4 at 25 mm depth to 18.4 at 32 mm depth, with insertion angles in the range of 26°–65°. Conclusions: A fiber-optic ultrasound receiver integrated into the needle cannula in combination with single-element transmissions from the imaging probe allows for direct visualization of the needle tip within the ultrasound imaging plane. Visualization of the needle tip was achieved at depths and insertion angles that are encountered during nerve blocks and fetal interventions. The method presented in this paper has strong potential to improve the safety and efficiency of ultrasound-guided needle insertions.« less

  2. Long-term biocompatibility, imaging appearance and tissue effects associated with delivery of a novel radiopaque embolization bead for image-guided therapy.

    PubMed

    Sharma, Karun V; Bascal, Zainab; Kilpatrick, Hugh; Ashrafi, Koorosh; Willis, Sean L; Dreher, Matthew R; Lewis, Andrew L

    2016-10-01

    The objective of this study was to undertake a comprehensive long-term biocompatibility and imaging assessment of a new intrinsically radiopaque bead (LC Bead LUMI™) for use in transarterial embolization. The sterilized device and its extracts were subjected to the raft of ISO10993 biocompatibility tests that demonstrated safety with respect to cytotoxicity, mutagenicity, blood contact, irritation, sensitization, systemic toxicity and tissue reaction. Intra-arterial administration was performed in a swine model of hepatic arterial embolization in which 0.22-1 mL of sedimented bead volume was administered to the targeted lobe(s) of the liver. The beads could be visualized during the embolization procedure with fluoroscopy, DSA and single X-ray snapshot imaging modalities. CT imaging was performed before and 1 h after embolization and then again at 7, 14, 30 and 90 days. LC Bead LUMI™ could be clearly visualized in the hepatic arteries with or without administration of IV contrast and appeared more dense than soluble contrast agent. The CT density of the beads did not deteriorate during the 90 day evaluation period. The beads embolized predictably and effectively, resulting in areas devoid of contrast enhancement on CT imaging suggesting ischaemia-induced necrosis nearby the sites of occlusion. Instances of off target embolization were easily detected on imaging and confirmed pathologically. Histopathology revealed a classic foreign body response at 14 days, which resolved over time leading to fibrosis and eventual integration of the beads into the tissue, demonstrating excellent long-term tissue compatibility. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  3. Effect of Music on Outpatient Urological Procedures: A Systematic Review and Meta-Analysis from the European Association of Urology Section of Uro-Technology.

    PubMed

    Kyriakides, Rena; Jones, Patrick; Geraghty, Robert; Skolarikos, Andreas; Liatsikos, Evangellos; Traxer, Olivier; Pietropaolo, Amelia; Somani, Bhaskar K

    2018-05-01

    Music is a practical, inexpensive and harmless analgesic and anxiolytic. An increasing number of original studies have been performed to investigate its potential application in urology. Our aim was to identify the effect of music on outpatient based urological procedures. We systematically reviewed the effect of using music during all reported outpatient urology procedures, including transrectal ultrasound guided prostate biopsy, shock wave lithotripsy, urodynamic studies, percutaneous nephrostomy tube placement and cystoscopy. Data were included on all randomized trials from 1980 to 2017 and no language restrictions were applied. Included in analysis were 16 randomized studies in which 972 of 1,950 patients (49.8%) were exposed to music during an outpatient procedure. The procedures included transrectal ultrasound guided prostate biopsy in 4 studies in a total of 286 patients, shock wave lithotripsy in 6 studies in a total of 1,023, cystoscopy in 3 studies in a total of 331, urodynamics in 2 studies in a total of 210 and percutaneous nephrostomy in 1 study in a total of 100. All studies incorporated a visual analog score to measure pain. Anxiety was measured by STAI (State-Trait Anxiety Inventory) in 13 studies and by a visual analog scale in 2. While 14 of the 16 studies showed a reduction in self-reported pain, a reduction in anxiety was seen in 14. When using music, overall procedural satisfaction was better in 9 studies and patient willingness to repeat the procedure was also higher in 7. Our meta-analysis revealed a significant reduction in visual analog scale and STAI findings across all studies (p <0.001). Our systematic review demonstrated a beneficial effect of music on urological outpatient procedures. Music seemed to decrease anxiety and pain. It might serve as a useful adjunct to increase procedural satisfaction and patient willingness to undergo the procedure again. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  4. A computational model to compare different investment scenarios for mini-stereotactic frame approach to deep brain stimulation surgery.

    PubMed

    Lanotte, M; Cavallo, M; Franzini, A; Grifi, M; Marchese, E; Pantaleoni, M; Piacentino, M; Servello, D

    2010-09-01

    Deep brain stimulation (DBS) alleviates symptoms of many neurological disorders by applying electrical impulses to the brain by means of implanted electrodes, generally put in place using a conventional stereotactic frame. A new image guided disposable mini-stereotactic system has been designed to help shorten and simplify DBS procedures when compared to standard stereotaxy. A small number of studies have been conducted which demonstrate localization accuracies of the system similar to those achievable by the conventional frame. However no data are available to date on the economic impact of this new frame. The aim of this paper was to develop a computational model to evaluate the investment required to introduce the image guided mini-stereotactic technology for stereotactic DBS neurosurgery. A standard DBS patient care pathway was developed and related costs were analyzed. A differential analysis was conducted to capture the impact of introducing the image guided system on the procedure workflow. The analysis was carried out in five Italian neurosurgical centers. A computational model was developed to estimate upfront investments and surgery costs leading to a definition of the best financial option to introduce the new frame. Investments may vary from Euro 1.900 (purchasing of Image Guided [IG] mini-stereotactic frame only) to Euro 158.000.000. Moreover the model demonstrates how the introduction of the IG mini-stereotactic frame doesn't substantially affect the DBS procedure costs.

  5. REAL TIME MRI GUIDED RADIOFREQUENCY ATRIAL ABLATION AND VISUALIZATION OF LESION FORMATION AT 3-TESLA

    PubMed Central

    Vergara, Gaston R.; Vijayakumar, Sathya; Kholmovski, Eugene G.; Blauer, Joshua J.E.; Guttman, Mike A.; Gloschat, Christopher; Payne, Gene; Vij, Kamal; Akoum, Nazem W.; Daccarett, Marcos; McGann, Christopher J.; MacLeod, Rob S.; Marrouche, Nassir F.

    2011-01-01

    Background MRI allows visualization of location and extent of RF ablation lesion, myocardial scar formation, and real-time (RT) assessment of lesion formation. In this study, we report a novel 3-Tesla RT-MRI based porcine RF ablation model and visualization of lesion formation in the atrium during RF energy delivery. Objective To develop of a 3-Tesla RT-MRI based catheter ablation and lesion visualization system. Methods RF energy was delivered to six pigs under RT-MRI guidance. A novel MRI compatible mapping and ablation catheter was used. Under RT-MRI this catheter was safely guided and positioned within either the left or right atrium. Unipolar and bi-polar electrograms were recorded. The catheter tip-tissue interface was visualized with a T1-weighted gradient echo sequence. RF energy was then delivered in a power-controlled fashion. Myocardial changes and lesion formation were visualized with a T2-weighted (T2w) HASTE sequence during ablation. Results Real-time visualization of lesion formation was achieved in 30% of the ablations performed. In the other cases, either the lesion was formed outside the imaged region (25%) or lesion was not created (45%) presumably due to poor tissue-catheter tip contact. The presence of lesions was confirmed by late gadolinium enhancement (LGE) MRI and macroscopic tissue examination. Conclusion MRI compatible catheters can be navigated and RF energy safely delivered under 3-Tesla RT-MRI guidance. It is also feasible to record electrograms during RT imaging. Real-time visualization of lesion as it forms during delivery of RF energy is possible and was demonstrated using T2w HASTE imaging. PMID:21034854

  6. Evaluation of the clinical benefit of an electromagnetic navigation system for CT-guided interventional radiology procedures in the thoraco-abdominal region compared with conventional CT guidance (CTNAV II): study protocol for a randomised controlled trial.

    PubMed

    Rouchy, R C; Moreau-Gaudry, A; Chipon, E; Aubry, S; Pazart, L; Lapuyade, B; Durand, M; Hajjam, M; Pottier, S; Renard, B; Logier, R; Orry, X; Cherifi, A; Quehen, E; Kervio, G; Favelle, O; Patat, F; De Kerviler, E; Hughes, C; Medici, M; Ghelfi, J; Mounier, A; Bricault, I

    2017-07-06

    Interventional radiology includes a range of minimally invasive image-guided diagnostic and therapeutic procedures that have become routine clinical practice. Each procedure involves a percutaneous needle insertion, often guided using computed tomography (CT) because of its availability and usability. However, procedures remain complicated, in particular when an obstacle must be avoided, meaning that an oblique trajectory is required. Navigation systems track the operator's instruments, meaning the position and progression of the instruments are visualised in real time on the patient's images. A novel electromagnetic navigation system for CT-guided interventional procedures (IMACTIS-CT®) has been developed, and a previous clinical trial demonstrated improved needle placement accuracy in navigation-assisted procedures. In the present trial, we are evaluating the clinical benefit of the navigation system during the needle insertion step of CT-guided procedures in the thoraco-abdominal region. This study is designed as an open, multicentre, prospective, randomised, controlled interventional clinical trial and is structured as a standard two-arm, parallel-design, individually randomised trial. A maximum of 500 patients will be enrolled. In the experimental arm (navigation system), the procedures are carried out using navigation assistance, and in the active comparator arm (CT), the procedures are carried out with conventional CT guidance. The randomisation is stratified by centre and by the expected difficulty of the procedure. The primary outcome of the trial is a combined criterion to assess the safety (number of serious adverse events), efficacy (number of targets reached) and performance (number of control scans acquired) of navigation-assisted, CT-guided procedures as evaluated by a blinded radiologist and confirmed by an expert committee in case of discordance. The secondary outcomes are (1) the duration of the procedure, (2) the satisfaction of the operator and (3) the irradiation dose delivered, with (4) subgroup analysis according to the expected difficulty of the procedure, as well as an evaluation of (5) the usability of the device. This trial addresses the lack of published high-level evidence studies in which navigation-assisted CT-guided interventional procedures are evaluated. This trial is important because it addresses the problems associated with conventional CT guidance and is particularly relevant because the number of interventional radiology procedures carried out in routine clinical practice is increasing. ClinicalTrials.gov identifier: NCT01896219 . Registered on 5 July 2013.

  7. Intraoperative Magnetic Resonance Imaging-Guided Biopsy in the Diagnosis of Suprasellar Langerhans Cell Histiocytosis.

    PubMed

    Carroll, Kate T; Lochte, Bryson C; Chen, James Y; Snyder, Vivian S; Carter, Bob S; Chen, Clark C

    2018-04-01

    Magnetic resonance imaging (MRI)-guided biopsy is an emerging diagnostic technique that holds great promise for otherwise difficult to access neuroanatomy. Here we describe MRI-guided biopsy of a suprasellar lesion located posterior and superior to the pituitary stalk. The approach was implemented successfully in a 38-year-old woman who had developed progressive visual deterioration. Intraoperative MRI revealed the need for trajectory adjustment due to an unintended, minor deviation in the burr hole entry point, demonstrating the benefit of an MRI-guided approach. Langerhans cell histiocytosis was diagnosed after biopsy, and the lesion regressed after cladribine treatment. Technical nuances of the case are reviewed in the context of the available literature. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. MassImager: A software for interactive and in-depth analysis of mass spectrometry imaging data.

    PubMed

    He, Jiuming; Huang, Luojiao; Tian, Runtao; Li, Tiegang; Sun, Chenglong; Song, Xiaowei; Lv, Yiwei; Luo, Zhigang; Li, Xin; Abliz, Zeper

    2018-07-26

    Mass spectrometry imaging (MSI) has become a powerful tool to probe molecule events in biological tissue. However, it is a widely held viewpoint that one of the biggest challenges is an easy-to-use data processing software for discovering the underlying biological information from complicated and huge MSI dataset. Here, a user-friendly and full-featured MSI software including three subsystems, Solution, Visualization and Intelligence, named MassImager, is developed focusing on interactive visualization, in-situ biomarker discovery and artificial intelligent pathological diagnosis. Simplified data preprocessing and high-throughput MSI data exchange, serialization jointly guarantee the quick reconstruction of ion image and rapid analysis of dozens of gigabytes datasets. It also offers diverse self-defined operations for visual processing, including multiple ion visualization, multiple channel superposition, image normalization, visual resolution enhancement and image filter. Regions-of-interest analysis can be performed precisely through the interactive visualization between the ion images and mass spectra, also the overlaid optical image guide, to directly find out the region-specific biomarkers. Moreover, automatic pattern recognition can be achieved immediately upon the supervised or unsupervised multivariate statistical modeling. Clear discrimination between cancer tissue and adjacent tissue within a MSI dataset can be seen in the generated pattern image, which shows great potential in visually in-situ biomarker discovery and artificial intelligent pathological diagnosis of cancer. All the features are integrated together in MassImager to provide a deep MSI processing solution at the in-situ metabolomics level for biomarker discovery and future clinical pathological diagnosis. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  9. Visualization and imaging methods for flames in microgravity

    NASA Technical Reports Server (NTRS)

    Weiland, Karen J.

    1993-01-01

    The visualization and imaging of flames has long been acknowledged as the starting point for learning about and understanding combustion phenomena. It provides an essential overall picture of the time and length scales of processes and guides the application of other diagnostics. It is perhaps even more important in microgravity combustion studies, where it is often the only non-intrusive diagnostic measurement easily implemented. Imaging also aids in the interpretation of single-point measurements, such as temperature, provided by thermocouples, and velocity, by hot-wire anemometers. This paper outlines the efforts of the Microgravity Combustion Diagnostics staff at NASA Lewis Research Center in the area of visualization and imaging of flames, concentrating on methods applicable for reduced-gravity experimentation. Several techniques are under development: intensified array camera imaging, and two-dimensional temperature and species concentrations measurements. A brief summary of results in these areas is presented and future plans mentioned.

  10. Reinforcing the role of the conventional C-arm - a novel method for simplified distal interlocking

    PubMed Central

    2012-01-01

    Background The common practice for insertion of distal locking screws of intramedullary nails is a freehand technique under fluoroscopic control. The process is technically demanding, time-consuming and afflicted to considerable radiation exposure of the patient and the surgical personnel. A new concept is introduced utilizing information from within conventional radiographic images to help accurately guide the surgeon to place the interlocking bolt into the interlocking hole. The newly developed technique was compared to conventional freehand in an operating room (OR) like setting on human cadaveric lower legs in terms of operating time and radiation exposure. Methods The proposed concept (guided freehand), generally based on the freehand gold standard, additionally guides the surgeon by means of visible landmarks projected into the C-arm image. A computer program plans the correct drilling trajectory by processing the lens-shaped hole projections of the interlocking holes from a single image. Holes can be drilled by visually aligning the drill to the planned trajectory. Besides a conventional C-arm, no additional tracking or navigation equipment is required. Ten fresh frozen human below-knee specimens were instrumented with an Expert Tibial Nail (Synthes GmbH, Switzerland). The implants were distally locked by performing the newly proposed technique as well as the conventional freehand technique on each specimen. An orthopedic resident surgeon inserted four distal screws per procedure. Operating time, number of images and radiation time were recorded and statistically compared between interlocking techniques using non-parametric tests. Results A 58% reduction in number of taken images per screw was found for the guided freehand technique (7.4 ± 3.4) (mean ± SD) compared to the freehand technique (17.6 ± 10.3) (p < 0.001). Total radiation time (all 4 screws) was 55% lower for the guided freehand technique compared to conventional freehand (p = 0.001). Operating time per screw (from first shot to screw tightened) was on average 22% reduced by guided freehand (p = 0.018). Conclusions In an experimental setting, the newly developed guided freehand technique for distal interlocking has proven to markedly reduce radiation exposure when compared to the conventional freehand technique. The method utilizes established clinical workflows and does not require cost intensive add-on devices or extensive training. The underlying principle carries potential to assist implant positioning in numerous other applications within orthopedics and trauma from screw insertions to placement of plates, nails or prostheses. PMID:22276698

  11. Improving patient and user safety during endoscopic investigation of the pancreatic and biliary ducts

    NASA Astrophysics Data System (ADS)

    Chandler, John E.; Melville, C. David; Lee, Cameron M.; Saunders, Michael D.; Burkhardt, Matthew R.; Seibel, Eric J.

    2011-03-01

    Endoscopic investigation of the main pancreatic duct and biliary ducts is called endoscopic retrograde cholangiopancreatography (ERCP), and carries a risk of pancreatitis for the patient. During ERCP, a metal guidewire is inserted into the pancreatobiliary duct from a side-viewing large endoscope within the duodenum. To verify correct placement of the ERCP guidewire, an injection of radiopaque dye is required for fluoroscopic imaging, which exposes the patient and clinical team to x-ray radiation. A safer and more effective means to access the pancreatobiliary system can use direct optical imaging, although the endoscope diameter and stiffness will be significantly larger than a guidewire's. To quantify this invasiveness before human testing, a synthetic force-sensing pancreas was fabricated and attached to an ERCP training model. The invasiveness of a new, 1.7-mm diameter, steerable scanning fiber endoscope (SFE) was compared to the standard ERCP guidewire of 0.89-mm (0.035") diameter that is not steerable. Although twice as large and significantly stiffer than the ERCP guidewire, the SFE generated lower or significantly less average force during insertion at all 4 sensor locations (P<0.05) within the main pancreatic duct. Therefore, the addition of steering and forward visualization at the tip of the endoscope reduced the invasiveness of the in vitro ERCP procedure. Since fluoroscopy is not required, risks associated with dye injection and x-ray exposure can be eliminated when using direct optical visualization. Finally, the SFE provides wide-field high resolution imaging for image-guided interventions, laser-based fluorescence biomarker imaging, and spot spectral analysis for future optical biopsy.

  12. Image-guided radiofrequency ablation of spinal tumors: preliminary experience with an expandable array electrode.

    PubMed

    Grönemeyer, Dietrich H W; Schirp, Sven; Gevargez, Athour

    2002-01-01

    Metastases to the spine are a challenging problem. Percutaneous, image-guided tumor ablation with a thermal energy source, such as radiofrequency, has received increasing attention as a promising technique for the treatment of focal malignant disease. We used radiofrequency ablation for patients with unresectable, osteolytic spine metastases under computed tomographic and fluoroscopic guidance. The purpose of this study was to determine the feasibility, effectiveness, and safety of radiofrequency ablation as a palliative procedure to reduce pain and back pain-related disability in patients with vertebral and paravertebral spine tumors who were not able to benefit from radiotherapy, chemotherapy, or surgery. Between November 1999 and January 2001, 10 patients with unresectable spine metastases were treated with radiofrequency ablation. For the ablation we used a 50-W radiofrequency generator that is connected to an expandable electrode catheter (RITA Medical System Inc., Mountain View, CA). The mean patient age was 64.4 years. Metastases were ablated in the thoracic spine, the lumbar spine, and/or the sacral bone. Tumor diameter ranged from 1.5 to 9 cm. Combined computed tomographic and fluoroscopic guidance was used to guide the procedure. Operations were carried out without heavy sedation with the patient under local anesthesia only. The thermal lesion was produced by applying temperatures of 50 degrees to 120 degrees C for 8-12 minutes. Vertebroplasty was performed in four patients by use of 3 to 5.5 mL of polymethyl methacrylate. Therapy outcome was documented by magnet resonance imaging. Before the therapy and on follow-up of an average of 5.8 months, pain was assessed with the help of the Visual Analogue Scale. Back pain-related disability was measured with the Hannover Functional Ability Questionnaire. Neurologic and health status were documented on the Frankel score and the Karnofsky index. At follow-up, 9 of 10 patients reported reduced pain (Visual Analogue Scale). In patients who experienced pain relief, there was an average relative pain reduction of 74.4%. Back pain-related disability was reduced by an average of 27%. Neurologic function was preserved in nine patients and improved in one. General health was stabilized in six patients, slightly increased (by 10%-20%) in two patients, significantly enhanced (by 50%) in one patient, and slightly reduced in one patient. No complications were reported. In the treated region, magnetic resonance imaging showed no further tumor growth after the therapy. Radiofrequency ablation was successfully performed in all 10 patients. Needles were placed accurately under image guidance, and a controlled lesion was created. Pain- and back pain-related disability was clearly reduced, and neurologic function was preserved or stabilized. When confirmed by further investigation, this therapy may be a new option for patients with unresectable spine tumors that do not respond to radiotherapy and chemotherapy.

  13. Magnetic resonance-guided prostate interventions.

    PubMed

    Haker, Steven J; Mulkern, Robert V; Roebuck, Joseph R; Barnes, Agnieska Szot; Dimaio, Simon; Hata, Nobuhiko; Tempany, Clare M C

    2005-10-01

    We review our experience using an open 0.5-T magnetic resonance (MR) interventional unit to guide procedures in the prostate. This system allows access to the patient and real-time MR imaging simultaneously and has made it possible to perform prostate biopsy and brachytherapy under MR guidance. We review MR imaging of the prostate and its use in targeted therapy, and describe our use of image processing methods such as image registration to further facilitate precise targeting. We describe current developments with a robot assist system being developed to aid radioactive seed placement.

  14. Wireless Medical Devices for MRI-Guided Interventions

    NASA Astrophysics Data System (ADS)

    Venkateswaran, Madhav

    Wireless techniques can play an important role in next-generation, image-guided surgical techniques with integration strategies being the key. We present our investigations on three wireless applications. First, we validate a position and orientation independent method to noninvasively monitor wireless power delivery using current perturbation measurements of switched load modulation of the RF carrier. This is important for safe and efficient powering without using bulky batteries or invasive cables. Use of MRI transmit RF pulses for simultaneous powering is investigated in the second part. We develop system models for the MRI transmit chain, wireless powering circuits and a typical load. Detailed analysis and validation of nonlinear and cascaded modeling strategies are performed, useful for decoupled optimization of the harvester coil and RF-DC converter. MRI pulse sequences are investigated for suitability for simultaneous powering. Simulations indicate that a 1.8V, 2 mA load can be powered with a 100% duty cycle using a 30° fGRE sequence, despite the RF duty cycle being 44 mW for a 30° flip angle, consistent with model predictions. Investigations on imaging artifacts indicates that distortion is mostly restricted to within the physical span of the harvester coil in the imaging volume, with the homogeneous B1+ transmit field providing positioning flexibility to minimize this for simultaneous powering. The models are potentially valuable in designing wireless powering solutions for implantable devices with simultaneous real-time imaging in MRI-guided surgical suites. Finally in the last section, we model endovascular MRI coil coupling during RF transmit. FEM models for a series-resonant multimode coil and quadrature birdcage coil fields are developed and computationally efficient, circuit and full-wave simulations are used to model inductive coupling. The Bloch Siegert B1 mapping sequence is used for validating at 24, 28 and 34 microT background excitation. Quantitative performance metrics are successfully predicted and the role of simulation in geometric optimization is demonstrated. In a pig study, we demonstrate navigation of a catheter, with tip-tracking and high-resolution intravascular imaging, through the vasculature into the heart, followed by contextual visualization. A potentially significant application is in MRI-guided cardiac ablation procedures.

  15. A deflectable guiding catheter for real-time MRI-guided interventions

    PubMed Central

    Bell, Jamie A.; Saikus, Christina E.; Ratnakaya, Kanishka; Wu, Vincent; Sonmez, Merdim; Faranesh, Anthony Z.; Colyer, Jessica H.; Lederman, Robert J.; Kocaturk, Ozgur

    2011-01-01

    Purpose To design a deflectable guiding catheter that omits long metallic components yet preserves mechanical properties to facilitate therapeutic interventional MRI procedures. Materials and Methods The catheter shaft incorporated Kevlar braiding. 180° deflection was attained with a 5 cm nitinol slotted tube, a nitinol spring, and a Kevlar pull string. We tested three designs: passive, passive incorporating an inductively-coupled coil, and active receiver. We characterized mechanical properties, MRI properties, RF induced heating, and in vivo performance in swine. Results Torque and tip deflection force were satisfactory. Representative procedures included hepatic and azygos vein access, laser cardiac septostomy, and atrial septal defect crossing. Visualization was best in the active configuration, delineating profile and tip orientation. The passive configuration could be used in tandem with an active guidewire to overcome its limited conspicuity. There was no RF-induced heating in all configurations under expected use conditions in vitro and in vivo. Conclusion Kevlar and short nitinol component substitutions preserved mechanical properties. The active design offered the best visibility and usability but reintroduced metal conductors. We describe versatile deflectable guiding catheters with a 0.057” lumen for interventional MRI catheterization. Implementations are feasible using active, inductive, and passive visualization strategies to suit application requirements. PMID:22128071

  16. Computer-Based Technologies in Dentistry: Types and Applications

    PubMed Central

    Albuha Al-Mussawi, Raja’a M.; Farid, Farzaneh

    2016-01-01

    During dental education, dental students learn how to examine patients, make diagnosis, plan treatment and perform dental procedures perfectly and efficiently. However, progresses in computer-based technologies including virtual reality (VR) simulators, augmented reality (AR) and computer aided design/computer aided manufacturing (CAD/CAM) systems have resulted in new modalities for instruction and practice of dentistry. Virtual reality dental simulators enable repeated, objective and assessable practice in various controlled situations. Superimposition of three-dimensional (3D) virtual images on actual images in AR allows surgeons to simultaneously visualize the surgical site and superimpose informative 3D images of invisible regions on the surgical site to serve as a guide. The use of CAD/CAM systems for designing and manufacturing of dental appliances and prostheses has been well established. This article reviews computer-based technologies, their application in dentistry and their potentials and limitations in promoting dental education, training and practice. Practitioners will be able to choose from a broader spectrum of options in their field of practice by becoming familiar with new modalities of training and practice. PMID:28392819

  17. Computer-Based Technologies in Dentistry: Types and Applications.

    PubMed

    Albuha Al-Mussawi, Raja'a M; Farid, Farzaneh

    2016-06-01

    During dental education, dental students learn how to examine patients, make diagnosis, plan treatment and perform dental procedures perfectly and efficiently. However, progresses in computer-based technologies including virtual reality (VR) simulators, augmented reality (AR) and computer aided design/computer aided manufacturing (CAD/CAM) systems have resulted in new modalities for instruction and practice of dentistry. Virtual reality dental simulators enable repeated, objective and assessable practice in various controlled situations. Superimposition of three-dimensional (3D) virtual images on actual images in AR allows surgeons to simultaneously visualize the surgical site and superimpose informative 3D images of invisible regions on the surgical site to serve as a guide. The use of CAD/CAM systems for designing and manufacturing of dental appliances and prostheses has been well established. This article reviews computer-based technologies, their application in dentistry and their potentials and limitations in promoting dental education, training and practice. Practitioners will be able to choose from a broader spectrum of options in their field of practice by becoming familiar with new modalities of training and practice.

  18. Ultrasonographic percutaneous anatomy of the atlanto-occipital region and indirect ultrasound-guided cisternal puncture in the dog and the cat.

    PubMed

    Etienne, A-L; Audigié, F; Peeters, D; Gabriel, A; Busoni, V

    2015-04-01

    Cisternal puncture in dogs and cats is commonly carried out. This article describes the percutaneous ultrasound anatomy of the cisternal region in the dog and the cat and an indirect technique for ultrasound-guided cisternal puncture. Ultrasound images obtained ex vivo and in vivo were compared with anatomic sections and used to identify the landmarks for ultrasound-guided cisternal puncture. The ultrasound-guided procedure was established in cadavers and then applied in vivo in seven dogs and two cats. The anatomic landmarks for the ultrasound-guided puncture are the cisterna magna, the spinal cord, the two occipital condyles on transverse images, the external occipital crest and the dorsal arch of the first cervical vertebra on longitudinal images. Using these ultrasound anatomic landmarks, an indirect ultrasound-guided technique for cisternal puncture is applicable in the dog and the cat. © 2014 Blackwell Verlag GmbH.

  19. Applications of Panoramic Images: from 720° Panorama to Interior 3d Models of Augmented Reality

    NASA Astrophysics Data System (ADS)

    Lee, I.-C.; Tsai, F.

    2015-05-01

    A series of panoramic images are usually used to generate a 720° panorama image. Although panoramic images are typically used for establishing tour guiding systems, in this research, we demonstrate the potential of using panoramic images acquired from multiple sites to create not only 720° panorama, but also three-dimensional (3D) point clouds and 3D indoor models. Since 3D modeling is one of the goals of this research, the location of the panoramic sites needed to be carefully planned in order to maintain a robust result for close-range photogrammetry. After the images are acquired, panoramic images are processed into 720° panoramas, and these panoramas which can be used directly as panorama guiding systems or other applications. In addition to these straightforward applications, interior orientation parameters can also be estimated while generating 720° panorama. These parameters are focal length, principle point, and lens radial distortion. The panoramic images can then be processed with closerange photogrammetry procedures to extract the exterior orientation parameters and generate 3D point clouds. In this research, VisaulSFM, a structure from motion software is used to estimate the exterior orientation, and CMVS toolkit is used to generate 3D point clouds. Next, the 3D point clouds are used as references to create building interior models. In this research, Trimble Sketchup was used to build the model, and the 3D point cloud was added to the determining of locations of building objects using plane finding procedure. In the texturing process, the panorama images are used as the data source for creating model textures. This 3D indoor model was used as an Augmented Reality model replacing a guide map or a floor plan commonly used in an on-line touring guide system. The 3D indoor model generating procedure has been utilized in two research projects: a cultural heritage site at Kinmen, and Taipei Main Station pedestrian zone guidance and navigation system. The results presented in this paper demonstrate the potential of using panoramic images to generate 3D point clouds and 3D models. However, it is currently a manual and labor-intensive process. A research is being carried out to Increase the degree of automation of these procedures.

  20. Construction of a high-tech operating room for image-guided surgery using VR.

    PubMed

    Suzuki, Naoki; Hattori, Asaki; Suzuki, Shigeyuki; Otake, Yoshito; Hayashibe, Mitsuhiro; Kobayashi, Susumu; Nezu, Takehiko; Sakai, Haruo; Umezawa, Yuji

    2005-01-01

    This project aimed to construct an operating room to implement high dimensional (3D, 4D) medical imaging and medical virtual reality techniques that would enable clinical tests for new surgical procedures. We designed and constructed such an operating room at Dai-san Hospital, the Jikei Univ. School of Medicine, Tokyo, Japan. The room was equipped with various facilities for image-guided, robot and tele- surgery. In this report, we describe an outline of our "high-tech operating room" and future plans.

  1. Practical Guide for the Selection of Audio Visual Media. General Criteria System and Evaluation Procedure for Educational Media Decisions.

    ERIC Educational Resources Information Center

    Klepzig, H. J.; Weiss, M.

    Designed to aid in making concrete decisions on the acquisition and use of media, the criteria system and evaluation procedure described is a multiphase, objective-based decision making process. This report includes guidelines for setting up goal systems and developing criteria for the evaluation of media based on a goal system; an outline of…

  2. Feasibility of Intraoperative Nerve Monitoring in Preventing Thermal Damage to the “Nerve at Risk” During Image-Guided Ablation of Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marshall, Richard H., E-mail: rmars1@lsuhsc.edu; Avila, Edward K., E-mail: avilae@mskcc.org; Solomon, Stephen B., E-mail: solomons@mskcc.org

    PurposeTo assess feasibility of intraoperative neurophysiologic monitoring (IONM) during image-guided, percutaneous thermal ablation of tumors.Materials and MethodsFrom February 2009 to October 2013, a retrospective review of all image-guided percutaneous thermal ablation interventions using IONM was performed and data was compiled using electronic medical records and imaging studies.ResultsTwelve patients were treated in 13 ablation interventions. In 4 patients, real-time feedback from the monitoring neurologist was used to adjust applicator placement and ablation settings. IONM was technically feasible in all procedures and there were no complications related to monitoring or ablation. All nerves at risk remained intact and of the 11 patientsmore » who could be followed, none developed new nerve deficit up to a minimum of 2 months after ablation.ConclusionIONM is safe and feasible for use during image-guided thermal ablation of tumors in the vicinity of nerves. Outcomes in this study demonstrate its potential utility in image-guided ablation interventions.« less

  3. A model of attention-guided visual perception and recognition.

    PubMed

    Rybak, I A; Gusakova, V I; Golovan, A V; Podladchikova, L N; Shevtsova, N A

    1998-08-01

    A model of visual perception and recognition is described. The model contains: (i) a low-level subsystem which performs both a fovea-like transformation and detection of primary features (edges), and (ii) a high-level subsystem which includes separated 'what' (sensory memory) and 'where' (motor memory) structures. Image recognition occurs during the execution of a 'behavioral recognition program' formed during the primary viewing of the image. The recognition program contains both programmed attention window movements (stored in the motor memory) and predicted image fragments (stored in the sensory memory) for each consecutive fixation. The model shows the ability to recognize complex images (e.g. faces) invariantly with respect to shift, rotation and scale.

  4. Image-Guided Spinal Ablation: A Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsoumakidou, Georgia, E-mail: gtsoumakidou@yahoo.com; Koch, Guillaume, E-mail: guillaume.koch@chru-strasbourg.fr; Caudrelier, Jean, E-mail: jean.caudrelier@chru-strasbourg.fr

    2016-09-15

    The image-guided thermal ablation procedures can be used to treat a variety of benign and malignant spinal tumours. Small size osteoid osteoma can be treated with laser or radiofrequency. Larger tumours (osteoblastoma, aneurysmal bone cyst and metastasis) can be addressed with radiofrequency or cryoablation. Results on the literature of spinal microwave ablation are scarce, and thus it should be used with caution. A distinct advantage of cryoablation is the ability to monitor the ice-ball by intermittent CT or MRI. The different thermal insulation, temperature and electrophysiological monitoring techniques should be applied. Cautious pre-procedural planning and intermittent intra-procedural monitoring of themore » ablation zone can help reduce neural complications. Tumour histology, patient clinical-functional status and life-expectancy should define the most efficient and least disabling treatment option.« less

  5. Investigating Surface and Near-Surface Bushfire Fuel Attributes: A Comparison between Visual Assessments and Image-Based Point Clouds.

    PubMed

    Spits, Christine; Wallace, Luke; Reinke, Karin

    2017-04-20

    Visual assessment, following guides such as the Overall Fuel Hazard Assessment Guide (OFHAG), is a common approach for assessing the structure and hazard of varying bushfire fuel layers. Visual assessments can be vulnerable to imprecision due to subjectivity between assessors, while emerging techniques such as image-based point clouds can offer land managers potentially more repeatable descriptions of fuel structure. This study compared the variability of estimates of surface and near-surface fuel attributes generated by eight assessment teams using the OFHAG and Fuels3D, a smartphone method utilising image-based point clouds, within three assessment plots in an Australian lowland forest. Surface fuel hazard scores derived from underpinning attributes were also assessed. Overall, this study found considerable variability between teams on most visually assessed variables, resulting in inconsistent hazard scores. Variability was observed within point cloud estimates but was, however, on average two to eight times less than that seen in visual estimates, indicating greater consistency and repeatability of this method. It is proposed that while variability within the Fuels3D method may be overcome through improved methods and equipment, inconsistencies in the OFHAG are likely due to the inherent subjectivity between assessors, which may be more difficult to overcome. This study demonstrates the capability of the Fuels3D method to efficiently and consistently collect data on fuel hazard and structure, and, as such, this method shows potential for use in fire management practices where accurate and reliable data is essential.

  6. Total body photography for skin cancer screening.

    PubMed

    Dengel, Lynn T; Petroni, Gina R; Judge, Joshua; Chen, David; Acton, Scott T; Schroen, Anneke T; Slingluff, Craig L

    2015-11-01

    Total body photography may aid in melanoma screening but is not widely applied due to time and cost. We hypothesized that a near-simultaneous automated skin photo-acquisition system would be acceptable to patients and could rapidly obtain total body images that enable visualization of pigmented skin lesions. From February to May 2009, a study of 20 volunteers was performed at the University of Virginia to test a prototype 16-camera imaging booth built by the research team and to guide development of special purpose software. For each participant, images were obtained before and after marking 10 lesions (five "easy" and five "difficult"), and images were evaluated to estimate visualization rates. Imaging logistical challenges were scored by the operator, and participant opinion was assessed by questionnaire. Average time for image capture was three minutes (range 2-5). All 55 "easy" lesions were visualized (sensitivity 100%, 90% CI 95-100%), and 54/55 "difficult" lesions were visualized (sensitivity 98%, 90% CI 92-100%). Operators and patients graded the imaging process favorably, with challenges identified regarding lighting and positioning. Rapid-acquisition automated skin photography is feasible with a low-cost system, with excellent lesion visualization and participant acceptance. These data provide a basis for employing this method in clinical melanoma screening. © 2014 The International Society of Dermatology.

  7. Restructuring the vocal fold lamina propria with endoscopic microdissection.

    PubMed

    Bartlett, Rebecca S; Hoffman, Henry T; Dailey, Seth H; Bock, Jonathan M; Klemuk, Sarah A; Askeland, Ryan W; Ahlrichs-Hanson, Jan S; Heaford, Andrew C; Thibeault, Susan L

    2013-11-01

    The purposes of this preclinical study were to investigate histologic and rheologic outcomes of Microendoscopy of Reinke's space (MERS)-guided minithyrotomy and to assess its instrumentation. Human cadaveric and in vivo animal study. Three human cadaveric larynges were treated with MERS-guided placement of Radiesse VoiceGel and immediately evaluated histologically for biomaterial location. In the second part of this investigation, two scarred porcine larynges were treated with MERS-guided placement of HyStem-VF and rheologically evaluated 6 weeks later. Student t tests determined differences in viscoelastic properties of treated/untreated vocal folds. Sialendoscopes and microendoscopes were subjectively compared for their visualization capacity. MERS imaged the subepithelial area and vocal ligament, guiding both tissue dissection and biomaterial positioning. Sialendoscopes provided adequate visualization and feature incorporated working channels. Enhanced image clarity was created in a gas-filled rather than saline-filled environment, per rater judgment. Histological analysis revealed desirable biomaterial positioning with MERS. Per rheological analysis, viscoelastic properties of the MERS-treated porcine vocal folds compared to uninjured vocal folds 6 weeks following treatment did not statistically differ. MERS-guided laryngoplasty using sialendoscopes yielded satisfactory biomaterial positioning in the short-term and normalized rheologic tissue properties in the long-term, contributing to proof of concept for MERS in the treatment of scarring. Strengths of MERS include direct, real-time visualization of Reinke's space and an ability to manipulate surgical instruments parallel to the vocal fold edge while maintaining an intact epithelium. Future work will explore the clinical utility of MERS for addressing scarring, sulcus vocalis, and other intracordal processes. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  8. [Clinical use of interventional MR imaging].

    PubMed

    Kahn, Thomas; Schulz, Thomas; Moche, Michael; Prothmann, Sascha; Schneider, Jens-Peter

    2003-01-01

    The integration of diagnostic and therapeutic procedures by MRI is based on the combination of excellent morphologic and functional imaging. The spectrum of MR-guided interventions includes biopsies, thermal ablation procedures, vascular applications, and intraoperative MRI. In all these applications, different scientific groups have obtained convincing results in basic developments as well as in clinical use. Interventional MRI (iMRI) is expected to attain an important role in interventional radiology, minimal invasive therapy, and monitoring of surgical procedures.

  9. A palm-sized high-sensitivity near-infrared fluorescence imager for laparotomy surgery.

    PubMed

    Dorval, Paul; Mangeret, Norman; Guillermet, Stephanie; Atallah, Ihab; Righini, Christian; Barabino, Gabriele; Coll, Jean-Luc; Rizo, Philippe; Poulet, Patrick

    2016-01-01

    In laparotomy surgery guided by near-infrared fluorescence imaging, the access to the field of operation is limited by the illumination and/or the imaging field. The side of cavities or organs such as the liver or the heart cannot be examined with the systems available on the market, which are too large and too heavy. In this article, we describe and evaluate a palm sized probe, whose properties, weight, size and sensitivity are adapted for guiding laparotomy surgery. Different experiments have been performed to determine its main characteristics, both on the illumination and imaging sides. The device has been tested for fluorescent molecular probe imaging in preclinical procedures, to prove its ability to be used in cancer nodule detection during surgery. This system is now CE certified for clinical procedures and Indocyanine Green imaging has been performed during clinical investigations: lymphedema and surgical resection of liver metastases of colorectal cancers. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  10. Successful Translation of Fluorescence Navigation During Oncologic Surgery: A Consensus Report.

    PubMed

    Rosenthal, Eben L; Warram, Jason M; de Boer, Esther; Basilion, James P; Biel, Merrill A; Bogyo, Matthew; Bouvet, Michael; Brigman, Brian E; Colson, Yolonda L; DeMeester, Steven R; Gurtner, Geoffrey C; Ishizawa, Takeaki; Jacobs, Paula M; Keereweer, Stijn; Liao, Joseph C; Nguyen, Quyen T; Olson, James M; Paulsen, Keith D; Rieves, Dwaine; Sumer, Baran D; Tweedle, Michael F; Vahrmeijer, Alexander L; Weichert, Jamey P; Wilson, Brian C; Zenn, Michael R; Zinn, Kurt R; van Dam, Gooitzen M

    2016-01-01

    Navigation with fluorescence guidance has emerged in the last decade as a promising strategy to improve the efficacy of oncologic surgery. To achieve routine clinical use, the onus is on the surgical community to objectively assess the value of this technique. This assessment may facilitate both Food and Drug Administration approval of new optical imaging agents and reimbursement for the imaging procedures. It is critical to characterize fluorescence-guided procedural benefits over existing practices and to elucidate both the costs and the safety risks. This report is the result of a meeting of the International Society of Image Guided Surgery (www.isigs.org) on February 6, 2015, in Miami, Florida, and reflects a consensus of the participants' opinions. Our objective was to critically evaluate the imaging platform technology and optical imaging agents and to make recommendations for successful clinical trial development of this highly promising approach in oncologic surgery. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  11. Biomedical sensing and imaging for the anterior segment of the eye

    NASA Astrophysics Data System (ADS)

    Eom, Tae Joong; Yoo, Young-Sik; Lee, Yong-Eun; Kim, Beop-Min; Joo, Choun-Ki

    2015-07-01

    Eye is an optical system composed briefly of cornea, lens, and retina. Ophthalmologists can diagnose status of patient's eye from information provided by optical sensors or images as well as from history taking or physical examinations. Recently, we developed a prototype of optical coherence tomography (OCT) image guided femtosecond laser cataract surgery system. The system combined a swept-source OCT and a femtosecond (fs) laser and afford the 2D and 3D structure information to increase the efficiency and safety of the cataract procedure. The OCT imaging range was extended to achieve the 3D image from the cornea to lens posterior. A prototype of OCT image guided fs laser cataract surgery system. The surgeons can plan the laser illumination range for the nuclear division and segmentation, and monitor the whole cataract surgery procedure using the real time OCT. The surgery system was demonstrated with an extracted pig eye and in vivo rabbit eye to verify the system performance and stability.

  12. Navigation concepts for magnetic resonance imaging-guided musculoskeletal interventions.

    PubMed

    Busse, Harald; Kahn, Thomas; Moche, Michael

    2011-08-01

    Image-guided musculoskeletal (MSK) interventions are a widely used alternative to open surgical procedures for various pathological findings in different body regions. They traditionally involve one of the established x-ray imaging techniques (radiography, fluoroscopy, computed tomography) or ultrasound scanning. Over the last decades, magnetic resonance imaging (MRI) has evolved into one of the most powerful diagnostic tools for nearly the whole body and has therefore been increasingly considered for interventional guidance as well.The strength of MRI for MSK applications is a combination of well-known general advantages, such as multiplanar and functional imaging capabilities, wide choice of tissue contrasts, and absence of ionizing radiation, as well as a number of MSK-specific factors, for example, the excellent depiction of soft-tissue tumors, nonosteolytic bone changes, and bone marrow lesions. On the downside, the magnetic resonance-compatible equipment needed, restricted space in the magnet, longer imaging times, and the more complex workflow have so far limited the number of MSK procedures under MRI guidance.Navigation solutions are generally a natural extension of any interventional imaging system, in particular, because powerful hardware and software for image processing have become routinely available. They help to identify proper access paths, provide accurate feedback on the instrument positions, facilitate the workflow in an MRI environment, and ultimately contribute to procedural safety and success.The purposes of this work were to describe some basic concepts and devices for MRI guidance of MSK procedures and to discuss technical and clinical achievements and challenges for some selected implementations.

  13. Real-time three dimensional CT and MRI to guide interventions for congenital heart disease and acquired pulmonary vein stenosis.

    PubMed

    Suntharos, Patcharapong; Setser, Randolph M; Bradley-Skelton, Sharon; Prieto, Lourdes R

    2017-10-01

    To validate the feasibility and spatial accuracy of pre-procedural 3D images to 3D rotational fluoroscopy registration to guide interventional procedures in patients with congenital heart disease and acquired pulmonary vein stenosis. Cardiac interventions in patients with congenital and structural heart disease require complex catheter manipulation. Current technology allows registration of the anatomy obtained from 3D CT and/or MRI to be overlaid onto fluoroscopy. Thirty patients scheduled for interventional procedures from 12/2012 to 8/2015 were prospectively recruited. A C-arm CT using a biplane C-arm system (Artis zee, VC14H, Siemens Healthcare) was acquired to enable 3D3D registration with pre-procedural images. Following successful image fusion, the anatomic landmarks marked in pre-procedural images were overlaid on live fluoroscopy. The accuracy of image registration was determined by measuring the distance between overlay markers and a reference point in the image. The clinical utility of the registration was evaluated as either "High", "Medium" or "None". Seventeen patients with congenital heart disease and 13 with acquired pulmonary vein stenosis were enrolled. Accuracy and benefit of registration were not evaluated in two patients due to suboptimal images. The distance between the marker and the actual anatomical location was 0-2 mm in 18 (64%), 2-4 mm in 3 (11%) and >4 mm in 7 (25%) patients. 3D3D registration was highly beneficial in 18 (64%), intermediate in 3 (11%), and not beneficial in 7 (25%) patients. 3D3D registration can facilitate complex congenital and structural interventions. It may reduce procedure time, radiation and contrast dose.

  14. MRI-guided stereotactic neurosurgical procedures in a diagnostic MRI suite: Background and safe practice recommendations.

    PubMed

    Larson, Paul S; Willie, Jon T; Vadivelu, Sudhakar; Azmi-Ghadimi, Hooman; Nichols, Amy; Fauerbach, Loretta Litz; Johnson, Helen Boehm; Graham, Denise

    2017-07-01

    The development of navigation technology facilitating MRI-guided stereotactic neurosurgery has enabled neurosurgeons to perform a variety of procedures ranging from deep brain stimulation to laser ablation entirely within an intraoperative or diagnostic MRI suite while having real-time visualization of brain anatomy. Prior to this technology, some of these procedures required multisite workflow patterns that presented significant risk to the patient during transport. For those facilities with access to this technology, safe practice guidelines exist only for procedures performed within an intraoperative MRI. There are currently no safe practice guidelines or parameters available for facilities looking to integrate this technology into practice in conventional MRI suites. Performing neurosurgical procedures in a diagnostic MRI suite does require precautionary measures. The relative novelty of technology and workflows for direct MRI-guided procedures requires consideration of safe practice recommendations, including those pertaining to infection control and magnet safety issues. This article proposes a framework of safe practice recommendations designed for assessing readiness and optimization of MRI-guided neurosurgical interventions in the diagnostic MRI suite in an effort to mitigate patient risk. The framework is based on existing clinical evidence, recommendations, and guidelines related to infection control and prevention, health care-associated infections, and magnet safety, as well as the clinical and practical experience of neurosurgeons utilizing this technology. © 2017 American Society for Healthcare Risk Management of the American Hospital Association.

  15. Visualization of Stereoscopic Anatomic Models of the Paranasal Sinuses and Cervical Vertebrae from the Surgical and Procedural Perspective

    ERIC Educational Resources Information Center

    Chen, Jian; Smith, Andrew D.; Khan, Majid A.; Sinning, Allan R.; Conway, Marianne L.; Cui, Dongmei

    2017-01-01

    Recent improvements in three-dimensional (3D) virtual modeling software allows anatomists to generate high-resolution, visually appealing, colored, anatomical 3D models from computed tomography (CT) images. In this study, high-resolution CT images of a cadaver were used to develop clinically relevant anatomic models including facial skull, nasal…

  16. Abnormal white matter tractography of visual pathways detected by high-angular-resolution diffusion imaging (HARDI) corresponds to visual dysfunction in cortical/cerebral visual impairment

    PubMed Central

    Bauer, Corinna M.; Heidary, Gena; Koo, Bang-Bon; Killiany, Ronald J.; Bex, Peter; Merabet, Lotfi B.

    2014-01-01

    Cortical (cerebral) visual impairment (CVI) is characterized by visual dysfunction associated with damage to the optic radiations and/or visual cortex. Typically it results from pre- or perinatal hypoxic damage to postchiasmal visual structures and pathways. The neuroanatomical basis of this condition remains poorly understood, particularly with regard to how the resulting maldevelopment of visual processing pathways relates to observations in the clinical setting. We report our investigation of 2 young adults diagnosed with CVI and visual dysfunction characterized by difficulties related to visually guided attention and visuospatial processing. Using high-angular-resolution diffusion imaging (HARDI), we characterized and compared their individual white matter projections of the extrageniculo-striate visual system with a normal-sighted control. Compared to a sighted control, both CVI cases revealed a striking reduction in association fibers, including the inferior frontal-occipital fasciculus as well as superior and inferior longitudinal fasciculi. This reduction in fibers associated with the major pathways implicated in visual processing may provide a neuroanatomical basis for the visual dysfunctions observed in these patients. PMID:25087644

  17. Feast for the Eyes: An Introduction to Data Visualization.

    PubMed

    Brigham, Tara J

    2016-01-01

    Data visualization is defined as the use of data presented in a graphical or pictorial manner. While data visualization is not a new concept, the ease with which anyone can create a data-drive chart, image, or visual has encouraged its growth. The increase of free sources of data and need for user-created content on social media has also led to a rise in data visualization's popularity. This column will explore what data visualization is and how it is currently being used. It will also discuss the benefits, potential problems, and uses in libraries. A brief list of visualization guides is included.

  18. Assessment of atherosclerotic luminal narrowing of coronary arteries based on morphometrically generated visual guides.

    PubMed

    Barth, Rolf F; Kellough, David A; Allenby, Patricia; Blower, Luke E; Hammond, Scott H; Allenby, Greg M; Buja, L Maximilian

    Determination of the degree of stenosis of atherosclerotic coronary arteries is an important part of postmortem examination of the heart, but, unfortunately, estimation of the degree of luminal narrowing can be imprecise and tends to be approximations. Visual guides can be useful to assess this, but earlier attempts to develop such guides did not employ digital technology. Using this approach, we have developed two computer-generated morphometric guides to estimate the degree of luminal narrowing of atherosclerotic coronary arteries. The first is based on symmetric or eccentric circular or crescentic narrowing of the vessel lumen and the second on either slit-like or irregularly shaped narrowing of the vessel lumens. Using the Aperio ScanScope XT at a magnification of 20× we created digital whole-slide images of 20 representative microscopic cross sections of the left anterior descending (LAD) coronary artery, stained with either hematoxylin and eosin (H&E) or Movat's pentachrome stain. These cross sections illustrated a variety of luminal profiles and degrees of stenosis. Three representative types of images were selected and a visual guide was constructed with Adobe Photoshop CS5. Using the "Scale" and "Measurement" tools, we created a series of representations of stenosis with luminal cross sections depicting 20%, 40%, 60%, 70%, 80%, and 90% occlusion of the LAD branch. Four pathologists independently reviewed and scored the degree of atherosclerotic luminal narrowing based on our visual guides. In addition, digital technology was employed to determine the degree of narrowing by measuring the cross-sectional area of the 20 microscopic sections of the vessels, first assuming no narrowing and then comparing this to the percent of narrowing determined by precise measurement. Two of the observers were very experienced general autopsy pathologists, one was a first-year pathology resident on his first rotation on the autopsy service, and the fourth observer was a highly experienced cardiovascular pathologist. Interobserver reliability was assessed by determination of the intraclass correlation coefficient. The degrees of agreement for two H&E- and Movat-stained sections of the LADs from each of 10 decedents were 0.874 and 0.899, respectively, indicating strong interobserver agreement. On the average, the mean visual scores were ~8% less than the morphometric assessment (52.7 vs. 60.2), respectively. The visual guides that we have generated for scoring atherosclerotic luminal narrowing of coronary arteries should be helpful for a broad group of pathologists, from beginning pathology residents to experienced cardiovascular pathologists. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Outcomes following implementation of a pediatric procedural sedation guide for referral to general anesthesia for magnetic resonance imaging studies.

    PubMed

    Grunwell, Jocelyn R; Marupudi, Neelima K; Gupta, Rohan V; Travers, Curtis D; McCracken, Courtney E; Williamson, Julie L; Stockwell, Jana A; Fortenberry, James D; Couloures, Kevin; Cravero, Joseph; Kamat, Pradip P

    2016-06-01

    Guidelines for referral of children to general anesthesia (GA) to complete MRI studies are lacking. We devised a pediatric procedural sedation guide to determine whether a pediatric procedural sedation guide would decrease serious adverse events and decrease failed sedations requiring rescheduling with GA. We constructed a consensus-based sedation guide by combining a retrospective review of reasons for referral of children to GA (n = 221) with published risk factors associated with the inability to complete the MRI study with sedation. An interrupted time series analysis of 11 530 local sedation records from the Pediatric Sedation Research Consortium between July 2008 and March 2013, adjusted for case-mix differences in the pre- and postsedation guide cohorts, evaluated whether a sedation guide resulted in decreased severe adverse events (SAE) and failed sedation rates. A significant increase in referrals to GA following implementation of a sedation guide occurred (P < 0.001), and fewer children with an ASA-PS class ≥III were sedated using procedural sedation (P < 0.001). There was no decrease in SAE (P = 0.874) or in SAE plus airway obstruction with concurrent hypoxia (P = 0.435). There was no change in the percentage of failed sedations (P = 0.169). More studies are needed to determine the impact of a sedation guide on pediatric procedural sedation services. © 2016 John Wiley & Sons Ltd.

  20. A novel Bayesian respiratory motion model to estimate and resolve uncertainty in image-guided cardiac interventions.

    PubMed

    Peressutti, Devis; Penney, Graeme P; Housden, R James; Kolbitsch, Christoph; Gomez, Alberto; Rijkhorst, Erik-Jan; Barratt, Dean C; Rhode, Kawal S; King, Andrew P

    2013-05-01

    In image-guided cardiac interventions, respiratory motion causes misalignments between the pre-procedure roadmap of the heart used for guidance and the intra-procedure position of the heart, reducing the accuracy of the guidance information and leading to potentially dangerous consequences. We propose a novel technique for motion-correcting the pre-procedural information that combines a probabilistic MRI-derived affine motion model with intra-procedure real-time 3D echocardiography (echo) images in a Bayesian framework. The probabilistic model incorporates a measure of confidence in its motion estimates which enables resolution of the potentially conflicting information supplied by the model and the echo data. Unlike models proposed so far, our method allows the final motion estimate to deviate from the model-produced estimate according to the information provided by the echo images, so adapting to the complex variability of respiratory motion. The proposed method is evaluated using gold-standard MRI-derived motion fields and simulated 3D echo data for nine volunteers and real 3D live echo images for four volunteers. The Bayesian method is compared to 5 other motion estimation techniques and results show mean/max improvements in estimation accuracy of 10.6%/18.9% for simulated echo images and 20.8%/41.5% for real 3D live echo data, over the best comparative estimation method. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Registration of fast cine cardiac MR slices to 3D preprocedural images: toward real-time registration for MRI-guided procedures

    NASA Astrophysics Data System (ADS)

    Smolikova, Renata; Wachowiak, Mark P.; Drangova, Maria

    2004-05-01

    Interventional cardiac magnetic resonance (MR) procedures are the subject of an increasing number of research studies. Typically, during the procedure only two-dimensional images of oblique slices can be presented to the interventionalist in real time. There is a clear benefit to being able to register the real-time 2D slices to a previously acquired 3D computed tomography (CT) or MR image of the heart. Results from a study of the accuracy of registration of 2D cardiac images of an anesthetized pig to a 3D volume obtained in diastole are presented. Fast cine MR images representing twenty phases of the cardiac cycle were obtained of a 2D slice in a known oblique orientation. The 2D images were initially mis-oriented at distances ranging from 2 to 20 mm, and rotations of +/-10 degrees about all three axes. Images from all 20 cardiac phases were registered to examine the effect of timing between the 2D image and the 3D pre-procedural image. Linear registration using mutual information computed with 64 histogram bins yielded the highest accuracy. For the diastolic phases, mean translation and rotation errors ranged between 0.91 and 1.32 mm and between 1.73 and 2.10 degrees. Scans acquired at other phases also had high accuracy. These results are promising for the use of real time MR in image-guided cardiac interventions, and demonstrate the feasibility of registering 2D oblique MR slices to previously acquired single-phase volumes without preprocessing.

  2. Improvement to visualization of nodes in breast cancer patients following audit: are we seeing the problem?

    PubMed

    Paterson, Carolyn L; Hendry, Fraser R; Bolster, Alison A

    2018-06-01

    Successful localization of nodes in breast cancer patients depends upon the effectiveness of the lymphoscintigraphy technique employed. A benefit of performing imaging as part of this procedure is that it allows sites to audit their technique. An audit of breast cancer patients at the Glasgow Royal Infirmary (GRI) hospital showed nodes to be visualized in only 81% of patients. Current guidelines state that nodes should be seen in more than 95% of patients. A period of investigation and review led to changes being made to the injection and imaging technique employed at the GRI site. Following these changes a re-audit was performed that showed that the node visualization rate has successfully been increased to 97%, thereby meeting the standards set in the guidelines. This technical note details the results of the initial audit and re-audit, and explains the investigation and changes made to clinical procedures at the GRI site to improve the node visualization rate. The challenges that can occur when performing breast sentinel node procedures are also discussed.

  3. Wavefront-Guided Scleral Lens Correction in Keratoconus

    PubMed Central

    Marsack, Jason D.; Ravikumar, Ayeswarya; Nguyen, Chi; Ticak, Anita; Koenig, Darren E.; Elswick, James D.; Applegate, Raymond A.

    2014-01-01

    Purpose To examine the performance of state-of-the-art wavefront-guided scleral contact lenses (wfgSCLs) on a sample of keratoconic eyes, with emphasis on performance quantified with visual quality metrics; and to provide a detailed discussion of the process used to design, manufacture and evaluate wfgSCLs. Methods Fourteen eyes of 7 subjects with keratoconus were enrolled and a wfgSCL was designed for each eye. High-contrast visual acuity and visual quality metrics were used to assess the on-eye performance of the lenses. Results The wfgSCL provided statistically lower levels of both lower-order RMS (p < 0.001) and higher-order RMS (p < 0.02) than an intermediate spherical equivalent scleral contact lens. The wfgSCL provided lower levels of lower-order RMS than a normal group of well-corrected observers (p < < 0.001). However, the wfgSCL does not provide less higher-order RMS than the normal group (p = 0.41). Of the 14 eyes studied, 10 successfully reached the exit criteria, achieving residual higher-order root mean square wavefront error (HORMS) less than or within 1 SD of the levels experienced by normal, age-matched subjects. In addition, measures of visual image quality (logVSX, logNS and logLIB) for the 10 eyes were well distributed within the range of values seen in normal eyes. However, visual performance as measured by high contrast acuity did not reach normal, age-matched levels, which is in agreement with prior results associated with the acute application of wavefront correction to KC eyes. Conclusions Wavefront-guided scleral contact lenses are capable of optically compensating for the deleterious effects of higher-order aberration concomitant with the disease, and can provide visual image quality equivalent to that seen in normal eyes. Longer duration studies are needed to assess whether the visual system of the highly aberrated eye wearing a wfgSCL is capable of producing visual performance levels typical of the normal population. PMID:24830371

  4. Stereotactic mammography imaging combined with 3D US imaging for image guided breast biopsy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Surry, K. J. M.; Mills, G. R.; Bevan, K.

    2007-11-15

    Stereotactic X-ray mammography (SM) and ultrasound (US) guidance are both commonly used for breast biopsy. While SM provides three-dimensional (3D) targeting information and US provides real-time guidance, both have limitations. SM is a long and uncomfortable procedure and the US guided procedure is inherently two dimensional (2D), requiring a skilled physician for both safety and accuracy. The authors developed a 3D US-guided biopsy system to be integrated with, and to supplement SM imaging. Their goal is to be able to biopsy a larger percentage of suspicious masses using US, by clarifying ambiguous structures with SM imaging. Features from SM andmore » US guided biopsy were combined, including breast stabilization, a confined needle trajectory, and dual modality imaging. The 3D US guided biopsy system uses a 7.5 MHz breast probe and is mounted on an upright SM machine for preprocedural imaging. Intraprocedural targeting and guidance was achieved with real-time 2D and near real-time 3D US imaging. Postbiopsy 3D US imaging allowed for confirmation that the needle was penetrating the target. The authors evaluated 3D US-guided biopsy accuracy of their system using test phantoms. To use mammographic imaging information, they registered the SM and 3D US coordinate systems. The 3D positions of targets identified in the SM images were determined with a target localization error (TLE) of 0.49 mm. The z component (x-ray tube to image) of the TLE dominated with a TLE{sub z} of 0.47 mm. The SM system was then registered to 3D US, with a fiducial registration error (FRE) and target registration error (TRE) of 0.82 and 0.92 mm, respectively. Analysis of the FRE and TRE components showed that these errors were dominated by inaccuracies in the z component with a FRE{sub z} of 0.76 mm and a TRE{sub z} of 0.85 mm. A stereotactic mammography and 3D US guided breast biopsy system should include breast compression for stability and safety and dual modality imaging for target localization. The system will provide preprocedural x-ray mammography information in the form of SM imaging along with real-time US imaging for needle guidance to a target. 3D US imaging will also be available for targeting, guidance, and biopsy verification immediately postbiopsy.« less

  5. Cone-beam computed tomography fusion and navigation for real-time positron emission tomography-guided biopsies and ablations: a feasibility study.

    PubMed

    Abi-Jaoudeh, Nadine; Mielekamp, Peter; Noordhoek, Niels; Venkatesan, Aradhana M; Millo, Corina; Radaelli, Alessandro; Carelsen, Bart; Wood, Bradford J

    2012-06-01

    To describe a novel technique for multimodality positron emission tomography (PET) fusion-guided interventions that combines cone-beam computed tomography (CT) with PET/CT before the procedure. Subjects were selected among patients scheduled for a biopsy or ablation procedure. The lesions were not visible with conventional imaging methods or did not have uniform uptake on PET. Clinical success was defined by adequate histopathologic specimens for molecular profiling or diagnosis and by lack of enhancement on follow-up imaging for ablation procedures. Time to target (time elapsed between the completion of the initial cone-beam CT scan and first tissue sample or treatment), total procedure time (time from the moment the patient was on the table until the patient was off the table), and number of times the needle was repositioned were recorded. Seven patients underwent eight procedures (two ablations and six biopsies). Registration and procedures were completed successfully in all cases. Clinical success was achieved in all biopsy procedures and in one of the two ablation procedures. The needle was repositioned once in one biopsy procedure only. On average, the time to target was 38 minutes (range 13-54 min). Total procedure time was 95 minutes (range 51-240 min, which includes composite ablation). On average, fluoroscopy time was 2.5 minutes (range 1.3-6.2 min). An integrated cone-beam CT software platform can enable PET-guided biopsies and ablation procedures without the need for additional specialized hardware. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  6. Prospective randomized comparison of rotational angiography with three-dimensional reconstruction and computed tomography merged with electro-anatomical mapping: a two center atrial fibrillation ablation study.

    PubMed

    Anand, Rishi; Gorev, Maxim V; Poghosyan, Hermine; Pothier, Lindsay; Matkins, John; Kotler, Gregory; Moroz, Sarah; Armstrong, James; Nemtsov, Sergei V; Orlov, Michael V

    2016-08-01

    To compare the efficacy and accuracy of rotational angiography with three-dimensional reconstruction (3DATG) image merged with electro-anatomical mapping (EAM) vs. CT-EAM. A prospective, randomized, parallel, two-center study conducted in 36 patients (25 men, age 65 ± 10 years) undergoing AF ablation (33 % paroxysmal, 67 % persistent) guided by 3DATG (group 1) vs. CT (group 2) image fusion with EAM. 3DATG was performed on the Philips Allura Xper FD 10 system. Procedural characteristics including time, radiation exposure, outcome, and navigation accuracy were compared between two groups. There was no significant difference between the groups in total procedure duration or time spent for various procedural steps. Minor differences in procedural characteristics were present between two centers. Segmentation and fusion time for 3DATG or CT-EAM was short and similar between both centers. Accuracy of navigation guided by either method was high and did not depend on left atrial size. Maintenance of sinus rhythm between the two groups was no different up to 24 months of follow-up. This study did not find superiority of 3DATG-EAM image merge to guide AF ablation when compared to CT-EAM fusion. Both merging techniques result in similar navigation accuracy.

  7. Getting a grip on reality: Grasping movements directed to real objects and images rely on dissociable neural representations.

    PubMed

    Freud, Erez; Macdonald, Scott N; Chen, Juan; Quinlan, Derek J; Goodale, Melvyn A; Culham, Jody C

    2018-01-01

    In the current era of touchscreen technology, humans commonly execute visually guided actions directed to two-dimensional (2D) images of objects. Although real, three-dimensional (3D), objects and images of the same objects share high degree of visual similarity, they differ fundamentally in the actions that can be performed on them. Indeed, previous behavioral studies have suggested that simulated grasping of images relies on different representations than actual grasping of real 3D objects. Yet the neural underpinnings of this phenomena have not been investigated. Here we used functional magnetic resonance imaging (fMRI) to investigate how brain activation patterns differed for grasping and reaching actions directed toward real 3D objects compared to images. Multivoxel Pattern Analysis (MVPA) revealed that the left anterior intraparietal sulcus (aIPS), a key region for visually guided grasping, discriminates between both the format in which objects were presented (real/image) and the motor task performed on them (grasping/reaching). Interestingly, during action planning, the representations of real 3D objects versus images differed more for grasping movements than reaching movements, likely because grasping real 3D objects involves fine-grained planning and anticipation of the consequences of a real interaction. Importantly, this dissociation was evident in the planning phase, before movement initiation, and was not found in any other regions, including motor and somatosensory cortices. This suggests that the dissociable representations in the left aIPS were not based on haptic, motor or proprioceptive feedback. Together, these findings provide novel evidence that actions, particularly grasping, are affected by the realness of the target objects during planning, perhaps because real targets require a more elaborate forward model based on visual cues to predict the consequences of real manipulation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. The Role of Simulation in Planning Intraoperative Magnetic Resonance Imaging-Guided Neurosurgical Procedures: A Case Report.

    PubMed

    Chowdhury, Tumul; Bergese, Sergio D; Soghomonyan, Suren; Cappellani, Ronald B

    2017-04-01

    Simulation of the actual procedure is a simple and yet effective method of increasing patient safety and reducing the rate of unexpected adverse effects. We present our experience with 2 cases of preprocedural simulation on healthy volunteers that were performed in the intraoperative magnetic resonance imaging suite. During one of the cases, we also simulated a scenario of sudden cardiac arrest. Such an approach helped us to refine the procedures and coordinate the work of different teams within the intraoperative magnetic resonance imaging suite as well as improve the quality of patient management.

  9. Evaluation of low-dose limits in 3D-2D rigid registration for surgical guidance

    NASA Astrophysics Data System (ADS)

    Uneri, A.; Wang, A. S.; Otake, Y.; Kleinszig, G.; Vogt, S.; Khanna, A. J.; Gallia, G. L.; Gokaslan, Z. L.; Siewerdsen, J. H.

    2014-09-01

    An algorithm for intensity-based 3D-2D registration of CT and C-arm fluoroscopy is evaluated for use in surgical guidance, specifically considering the low-dose limits of the fluoroscopic x-ray projections. The registration method is based on a framework using the covariance matrix adaptation evolution strategy (CMA-ES) to identify the 3D patient pose that maximizes the gradient information similarity metric. Registration performance was evaluated in an anthropomorphic head phantom emulating intracranial neurosurgery, using target registration error (TRE) to characterize accuracy and robustness in terms of 95% confidence upper bound in comparison to that of an infrared surgical tracking system. Three clinical scenarios were considered: (1) single-view image + guidance, wherein a single x-ray projection is used for visualization and 3D-2D guidance; (2) dual-view image + guidance, wherein one projection is acquired for visualization, combined with a second (lower-dose) projection acquired at a different C-arm angle for 3D-2D guidance; and (3) dual-view guidance, wherein both projections are acquired at low dose for the purpose of 3D-2D guidance alone (not visualization). In each case, registration accuracy was evaluated as a function of the entrance surface dose associated with the projection view(s). Results indicate that images acquired at a dose as low as 4 μGy (approximately one-tenth the dose of a typical fluoroscopic frame) were sufficient to provide TRE comparable or superior to that of conventional surgical tracking, allowing 3D-2D guidance at a level of dose that is at most 10% greater than conventional fluoroscopy (scenario #2) and potentially reducing the dose to approximately 20% of the level in a conventional fluoroscopically guided procedure (scenario #3).

  10. Diffuse reflectance imaging: a tool for guided biopsy

    NASA Astrophysics Data System (ADS)

    Jayanthi, Jayaraj L.; Subhash, Narayanan; Manju, Stephen; Nisha, Unni G.; Beena, Valappil T.

    2012-01-01

    Accurate diagnosis of premalignant or malignant oral lesions depends on the quality of the biopsy, adequate clinical information and correct interpretation of the biopsy results. The major clinical challenge is to precisely locate the biopsy site in a clinically suspicious lesion. Dips due to oxygenated hemoglobin absorption have been noticed at 545 and 575 nm in the diffusely reflected white light spectra of oral mucosa and the intensity ratio R545/R575 has been found suited for early detection of oral pre-cancers. A multi-spectral diffuse reflectance (DR) imaging system has been developed consisting of an electron multiplying charge coupled device (EMCCD) camera and a liquid crystal tunable filter for guiding the clinician to an optimal biopsy site. Towards this DR images were recorded from 27 patients with potentially malignant lesions on their tongue (dorsal, lateral and ventral sides) and from 44 healthy controls at 545 and 575 nm with the DR imaging system. False colored ratio image R545/R575 of the lesion provides a visual discerning capability that helps in locating the most malignant site for biopsy. Histopathological report of guided biopsy showed that out of the 27 patients 16 were cancers, 9 pre-cancers and 2 lichen planus. In this clinical trial DR imaging has correctly guided 25 biopsy sites, yielding a sensitivity of 93% and a specificity of 98%, thereby establishing the potential of DR imaging as a tool for guided biopsy.

  11. Fiber Optic Force Sensors for MRI-Guided Interventions and Rehabilitation: A Review

    PubMed Central

    Iordachita, Iulian I.; Tokuda, Junichi; Hata, Nobuhiko; Liu, Xuan; Seifabadi, Reza; Xu, Sheng; Wood, Bradford; Fischer, Gregory S.

    2017-01-01

    Magnetic Resonance Imaging (MRI) provides both anatomical imaging with excellent soft tissue contrast and functional MRI imaging (fMRI) of physiological parameters. The last two decades have witnessed the manifestation of increased interest in MRI-guided minimally invasive intervention procedures and fMRI for rehabilitation and neuroscience research. Accompanying the aspiration to utilize MRI to provide imaging feedback during interventions and brain activity for neuroscience study, there is an accumulated effort to utilize force sensors compatible with the MRI environment to meet the growing demand of these procedures, with the goal of enhanced interventional safety and accuracy, improved efficacy and rehabilitation outcome. This paper summarizes the fundamental principles, the state of the art development and challenges of fiber optic force sensors for MRI-guided interventions and rehabilitation. It provides an overview of MRI-compatible fiber optic force sensors based on different sensing principles, including light intensity modulation, wavelength modulation, and phase modulation. Extensive design prototypes are reviewed to illustrate the detailed implementation of these principles. Advantages and disadvantages of the sensor designs are compared and analyzed. A perspective on the future development of fiber optic sensors is also presented which may have additional broad clinical applications. Future surgical interventions or rehabilitation will rely on intelligent force sensors to provide situational awareness to augment or complement human perception in these procedures. PMID:28652857

  12. Contrast-Enhanced C-arm Computed Tomography Imaging of Myocardial Infarction in the Interventional Suite

    PubMed Central

    Girard, Erin E; Al-Ahmad, Amin; Rosenberg, Jarrett; Luong, Richard; Moore, Teri; Lauritsch, Günter; Chan, Frandics; Lee, David P.; Fahrig, Rebecca

    2014-01-01

    Objectives Cardiac C-arm CT uses a standard C-arm fluoroscopy system rotating around the patient to provide CT-like images during interventional procedures without moving the patient to a conventional CT scanner. We hypothesize that C-arm computed tomography (CT) can be used to visualize and quantify the size of perfusion defects and late enhancement resulting from a myocardial infarction (MI) using contrast enhanced techniques similar to previous CT and magnetic resonance imaging studies. Materials and Methods A balloon occlusion followed by reperfusion in a coronary artery was used to study acute and subacute MI in 12 swine. ECG-gated C-arm CT images were acquired the day of infarct creation (n=6) or 4 weeks after infarct creation (n = 6). Images were acquired immediately following contrast injection, then at 1 minute, and every 5 minutes up to 30 minutes with no additional contrast. The volume of the infarct as measured on C-arm CT was compared against pathology. Results The volume of acute MI, visualized as a combined region of hyperenhancement with a hypoenhanced core, correlated well with pathologic staining (concordance correlation = 0.89, p<0.0001, mean difference = 0.67±2.98 cm3). The volume of subacute MI, visualized as a region of hyperenhancement, correlated well with pathologic staining at imaging times 5–15 minutes following contrast injection (concordance correlation = 0.82, p<.001, mean difference = −0.64±1.94 cm3). Conclusions C-arm CT visualization of acute and subacute myocardial infarction is possible in a porcine model but improvement in the imaging technique is important before clinical use. Visualization of MI in the catheterization lab may be possible and could provide 3D images for guidance during interventional procedures. PMID:25635589

  13. WE-EF-BRD-01: Past, Present and Future: MRI-Guided Radiotherapy From 2005 to 2025

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lagendijk, J.

    MRI-guided treatment is a growing area of medicine, particularly in radiotherapy and surgery. The exquisite soft tissue anatomic contrast offered by MRI, along with functional imaging, makes the use of MRI during therapeutic procedures very attractive. Challenging the utility of MRI in the therapy room are many issues including the physics of MRI and the impact on the environment and therapeutic instruments, the impact of the room and instruments on the MRI; safety, space, design and cost. In this session, the applications and challenges of MRI-guided treatment will be described. The session format is: Past, present and future: MRI-guided radiotherapymore » from 2005 to 2025: Jan Lagendijk Battling Maxwell’s equations: Physics challenges and solutions for hybrid MRI systems: Paul Keall I want it now!: Advances in MRI acquisition, reconstruction and the use of priors to enable fast anatomic and physiologic imaging to inform guidance and adaptation decisions: Yanle Hu MR in the OR: The growth and applications of MRI for interventional radiology and surgery: Rebecca Fahrig Learning Objectives: To understand the history and trajectory of MRI-guided radiotherapy To understand the challenges of integrating MR imaging systems with linear accelerators To understand the latest in fast MRI methods to enable the visualisation of anatomy and physiology on radiotherapy treatment timescales To understand the growing role and challenges of MRI for image-guided surgical procedures My disclosures are publicly available and updated at: http://sydney.edu.au/medicine/radiation-physics/about-us/disclosures.php.« less

  14. Optical see-through cancer vision goggles enable direct patient visualization and real-time fluorescence-guided oncologic surgery

    PubMed Central

    Mondal, Suman B.; Gao, Shengkui; Zhu, Nan; Hebimana-Griffin, LeMoyne; Akers, Walter J.; Liang, Rongguang; Gruev, Viktor; Margenthaler, Julie; Achilefu, Samuel

    2017-01-01

    Background The inability to directly visualize the patient and surgical site limits the use of current near infrared fluorescence-guided surgery systems for real-time sentinel lymph node biopsy and tumor margin assessment. Methods We evaluated an optical see-through goggle augmented imaging and navigation system (GAINS) for near-infrared fluorescence-guided surgery. Tumor-bearing mice injected with a near infrared cancer-targeting agent underwent fluorescence-guided tumor resection. Female Yorkshire pigs received hind leg intradermal indocyanine green injection and underwent fluorescence-guided popliteal lymph node resection. Four breast cancer patients received 99mTc-sulfur colloid and indocyanine green retroareolarly, before undergoing sentinel lymph node biopsy using radioactive tracking and fluorescence imaging. Three other breast cancer patients received indocyanine green retroareolarly before undergoing standard-of-care partial mastectomy, followed by fluorescence imaging of resected tumor and tumor cavity for margin assessment. Results Using near-infrared fluorescence from the dyes, the optical see-through GAINS accurately identified all mouse tumors, pig lymphatics, and 4 pig popliteal lymph nodes with high signal-to-background ratio. In 4 human breast cancer patients, 11 sentinel lymph nodes were identified with a detection sensitivity of 86.67± 0.27% for radioactive tracking and 100% for GAINS. Tumor margin status was accurately predicted by GAINS in all three patients, including clear margins in patients 1 and 2 and positive margins in patient 3 as confirmed by paraffin embedded section histopathology. Conclusions The optical see-through GAINS prototype enhances near infrared fluorescence-guided surgery for sentinel lymph node biopsy and tumor margin assessment in breast cancer patients without disrupting the surgical workflow in the operating room. PMID:28213790

  15. Optical See-Through Cancer Vision Goggles Enable Direct Patient Visualization and Real-Time Fluorescence-Guided Oncologic Surgery.

    PubMed

    Mondal, Suman B; Gao, Shengkui; Zhu, Nan; Habimana-Griffin, LeMoyne; Akers, Walter J; Liang, Rongguang; Gruev, Viktor; Margenthaler, Julie; Achilefu, Samuel

    2017-07-01

    The inability to visualize the patient and surgical site directly, limits the use of current near infrared fluorescence-guided surgery systems for real-time sentinel lymph node biopsy and tumor margin assessment. We evaluated an optical see-through goggle augmented imaging and navigation system (GAINS) for near-infrared, fluorescence-guided surgery. Tumor-bearing mice injected with a near infrared cancer-targeting agent underwent fluorescence-guided, tumor resection. Female Yorkshire pigs received hind leg intradermal indocyanine green injection and underwent fluorescence-guided, popliteal lymph node resection. Four breast cancer patients received 99m Tc-sulfur colloid and indocyanine green retroareolarly before undergoing sentinel lymph node biopsy using radioactive tracking and fluorescence imaging. Three other breast cancer patients received indocyanine green retroareolarly before undergoing standard-of-care partial mastectomy, followed by fluorescence imaging of resected tumor and tumor cavity for margin assessment. Using near-infrared fluorescence from the dyes, the optical see-through GAINS accurately identified all mouse tumors, pig lymphatics, and four pig popliteal lymph nodes with high signal-to-background ratio. In 4 human breast cancer patients, 11 sentinel lymph nodes were identified with a detection sensitivity of 86.67 ± 0.27% for radioactive tracking and 100% for GAINS. Tumor margin status was accurately predicted by GAINS in all three patients, including clear margins in patients 1 and 2 and positive margins in patient 3 as confirmed by paraffin-embedded section histopathology. The optical see-through GAINS prototype enhances near infrared fluorescence-guided surgery for sentinel lymph node biopsy and tumor margin assessment in breast cancer patients without disrupting the surgical workflow in the operating room.

  16. The use of virtual fiducials in image-guided kidney surgery

    NASA Astrophysics Data System (ADS)

    Glisson, Courtenay; Ong, Rowena; Simpson, Amber; Clark, Peter; Herrell, S. D.; Galloway, Robert

    2011-03-01

    The alignment of image-space to physical-space lies at the heart of all image-guided procedures. In intracranial surgery, point-based registrations can be used with either skin-affixed or bone-implanted extrinsic objects called fiducial markers. The advantages of point-based registration techniques are that they are robust, fast, and have a well developed mathematical foundation for the assessment of registration quality. In abdominal image-guided procedures such techniques have not been successful. It is difficult to accurately locate sufficient homologous intrinsic points in imagespace and physical-space, and the implantation of extrinsic fiducial markers would constitute "surgery before the surgery." Image-space to physical-space registration for abdominal organs has therefore been dominated by surfacebased registration techniques which are iterative, prone to local minima, sensitive to initial pose, and sensitive to percentage coverage of the physical surface. In our work in image-guided kidney surgery we have developed a composite approach using "virtual fiducials." In an open kidney surgery, the perirenal fat is removed and the surface of the kidney is dotted using a surgical marker. A laser range scanner (LRS) is used to obtain a surface representation and matching high definition photograph. A surface to surface registration is performed using a modified iterative closest point (ICP) algorithm. The dots are extracted from the high definition image and assigned the three dimensional values from the LRS pixels over which they lie. As the surgery proceeds, we can then use point-based registrations to re-register the spaces and track deformations due to vascular clamping and surgical tractions.

  17. Using a visual discrimination model for the detection of compression artifacts in virtual pathology images.

    PubMed

    Johnson, Jeffrey P; Krupinski, Elizabeth A; Yan, Michelle; Roehrig, Hans; Graham, Anna R; Weinstein, Ronald S

    2011-02-01

    A major issue in telepathology is the extremely large and growing size of digitized "virtual" slides, which can require several gigabytes of storage and cause significant delays in data transmission for remote image interpretation and interactive visualization by pathologists. Compression can reduce this massive amount of virtual slide data, but reversible (lossless) methods limit data reduction to less than 50%, while lossy compression can degrade image quality and diagnostic accuracy. "Visually lossless" compression offers the potential for using higher compression levels without noticeable artifacts, but requires a rate-control strategy that adapts to image content and loss visibility. We investigated the utility of a visual discrimination model (VDM) and other distortion metrics for predicting JPEG 2000 bit rates corresponding to visually lossless compression of virtual slides for breast biopsy specimens. Threshold bit rates were determined experimentally with human observers for a variety of tissue regions cropped from virtual slides. For test images compressed to their visually lossless thresholds, just-noticeable difference (JND) metrics computed by the VDM were nearly constant at the 95th percentile level or higher, and were significantly less variable than peak signal-to-noise ratio (PSNR) and structural similarity (SSIM) metrics. Our results suggest that VDM metrics could be used to guide the compression of virtual slides to achieve visually lossless compression while providing 5-12 times the data reduction of reversible methods.

  18. Ultrasound-guided Interventions for Core and Hip Injuries in Athletes.

    PubMed

    McCarthy, Eoghan; Hegazi, Tarek M; Zoga, Adam C; Morrison, William B; Meyers, William C; Poor, Alex E; Nevalainen, Mika T; Roedl, Johannes B

    2016-09-01

    Trauma and the mechanical strain of high-energy activity predispose athletes to pelvic injuries. Magnetic resonance imaging remains the primary modality for diagnosing these conditions, but ultrasonography-guided interventions are important in the management of core muscle, hip, and other pelvic conditions. This article reviews ultrasonography-guided interventions for injuries at the core, including the pelvis and hips. It reviews common injuries, procedure optimization, medication preparation, clinical evidence behind injections, tenotomy, and platelet-rich plasma. These interventions are especially important in athletes, because ultrasonography-guided procedures are often undertaken early in the treatment process, paralleling conservative rehabilitation to facilitate a faster return to play. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Ultrasound-guided peripheral nerve interventions for common pain disorders

    PubMed Central

    Krishna Prasad, B P; Joy, Binu; Raghavendra, Vijayakumar A; Toms, Ajith; George, Danny; Ray, Brijesh

    2018-01-01

    There are a number of common pain disorders that can be managed effectively by injections around or ablation of peripheral nerves. Ultrasound is a universally available imaging tool, is safe, cost-effective, and is excellent in imaging many peripheral nerves and guiding needles to the site of the nerves. This article aims to present an overview of indications and techniques of such procedures that can be effectively performed by a radiologist. PMID:29692534

  20. Development and preliminary evaluation of an ultrasonic motor actuated needle guide for 3T MRI-guided transperineal prostate interventions

    NASA Astrophysics Data System (ADS)

    Song, Sang-Eun; Tokuda, Junichi; Tuncali, Kemal; Tempany, Clare; Hata, Nobuhiko

    2012-02-01

    Image guided prostate interventions have been accelerated by Magnetic Resonance Imaging (MRI) and robotic technologies in the past few years. However, transrectal ultrasound (TRUS) guided procedure still remains as vast majority in clinical practice due to engineering and clinical complexity of the MRI-guided robotic interventions. Subsequently, great advantages and increasing availability of MRI have not been utilized at its maximum capacity in clinic. To benefit patients from the advantages of MRI, we developed an MRI-compatible motorized needle guide device "Smart Template" that resembles a conventional prostate template to perform MRI-guided prostate interventions with minimal changes in the clinical procedure. The requirements and specifications of the Smart Template were identified from our latest MRI-guided intervention system that has been clinically used in manual mode for prostate biopsy. Smart Template consists of vertical and horizontal crossbars that are driven by two ultrasonic motors via timing-belt and mitergear transmissions. Navigation software that controls the crossbar position to provide needle insertion positions was also developed. The software can be operated independently or interactively with an open-source navigation software, 3D Slicer, that has been developed for prostate intervention. As preliminary evaluation, MRI distortion and SNR test were conducted. Significant MRI distortion was found close to the threaded brass alloy components of the template. However, the affected volume was limited outside the clinical region of interest. SNR values over routine MRI scan sequences for prostate biopsy indicated insignificant image degradation during the presence of the robotic system and actuation of the ultrasonic motors.

  1. Sodium Fluorescein-Guided Resection under the YELLOW 560 nm Surgical Microscope Filter in Malignant Gliomas: Our First 38 Cases Experience.

    PubMed

    Zhang, Ningning; Tian, Hailong; Huang, Dezhang; Meng, Xianbing; Guo, Wenqiang; Wang, Chaochao; Yin, Xin; Zhang, Hongying; Jiang, Bin; He, Zheng; Wang, Zhigang

    2017-01-01

    Sodium fluorescein (FL) had been safely used in fluorescence-guided microsurgery for imaging various brain tumors. Under the YELLOW 560 nm surgical microscope filter, low-dose FL as a fluorescent dye helps in visualization. Our study investigated the safety and efficacy of this innovative technique in malignant glioma (MG) patients. 38 patients suffering from MGs confirmed by pathology underwent FL-guided resection under YELLOW 560 nm surgical microscope filter. We retrospectively analyzed the clinical characters, microsurgery procedure, extent of resection, pathology of MGs, progression-free survival (PFS), and overall survival (OS). Thirty-eight patients had MGs (10 WHO grade III, 28 WHO grade IV). With YELLOW 560 nm surgical microscope filter combined with neuronavigation, sodium fluorescein-guided gross total resection (GTR) was achieved in 35 (92.1%) patients and subtotal resection in 3 (7.69%). The sensitivity and specificity of FL were 94.4% and 88.6% regardless of radiographic localization. Intraoperatively, 10 biopsies (10/28 FL[+]) showed "low" or "high" fluorescence in non-contrast-enhancement region and are also confirmed by pathology. Our data showed 6-month PFS of 92.3% and median survival of 11 months. FL-guided resection of MGs under the YELLOW 560 nm surgical microscope filter combined with neuronavigation was safe and effective, especially in non-contrast-MRI regions. It is feasible for improving the extent of resection in MGs especially during emergency cases.

  2. Real-Time MRI-Guided Endovascular Recanalization of Chronic Total Arterial Occlusion in a Swine Model

    PubMed Central

    Raval, Amish N.; Karmarkar, Parag V.; Guttman, Michael A.; Ozturk, Cengizhan; Sampath, Smita; DeSilva, Ranil; Aviles, Ronnier J.; Xu, Minnan; Wright, Victor J.; Schenke, William H.; Kocaturk, Ozgur; Dick, Alexander J.; Raman, Venkatesh K.; Atalar, Ergin; McVeigh, Elliot R.; Lederman, Robert J.

    2006-01-01

    Background Endovascular recanalization (guidewire traversal) of peripheral artery chronic total occlusion (CTO) can be challenging. X-Ray angiography resolves CTO poorly. Virtually “blind” device advancement during X-ray-guided interventions can lead to procedure failure, perforation and hemorrhage. Alternatively, magnetic resonance imaging (MRI) may delineate the artery within the occluded segment to enhance procedural safety and success. We hypothesized that real-time MRI (rtMRI) guided CTO recanalization can be accomplished in an animal model. Methods and Results Carotid artery CTO was created by balloon injury in 19 lipid overfed swine. After 6–8 weeks, two underwent direct necropsy analysis for histology, three underwent primary X-ray-guided CTO recanalization attempts, and the remaining 14 underwent rtMRI-guided recanalization attempts in a 1.5T interventional MRI system. rtMRI intervention used custom CTO catheters and guidewires that incorporated MRI receiver antennae to enhance device visibility. The mean length of the occluded segments was 13.3 ± 1.6cm. rtMRI-guided CTO recanalization was successful in 11/14 swine and only 1/3 swine using X-ray alone. After unsuccessful rtMRI (n = 3), X-ray-guided attempts also were all unsuccessful. Conclusions Recanalization of long CTO is feasible entirely using rtMRI guidance. Low profile clinical-grade devices will be required to translate this experience to humans. Endovascular recanalization of chronic total arterial occlusion (CTO) is challenging under conventional X-ray guidance because devices are advanced almost blindly. MRI can image CTO borders and luminal contents, and could potentially guide these procedures. We test the feasibility of real-time MRI guided wire traversal in a swine model of peripheral artery CTO using custom active MRI catheters. PMID:16490819

  3. Dual-Tree Complex Wavelet Transform and Image Block Residual-Based Multi-Focus Image Fusion in Visual Sensor Networks

    PubMed Central

    Yang, Yong; Tong, Song; Huang, Shuying; Lin, Pan

    2014-01-01

    This paper presents a novel framework for the fusion of multi-focus images explicitly designed for visual sensor network (VSN) environments. Multi-scale based fusion methods can often obtain fused images with good visual effect. However, because of the defects of the fusion rules, it is almost impossible to completely avoid the loss of useful information in the thus obtained fused images. The proposed fusion scheme can be divided into two processes: initial fusion and final fusion. The initial fusion is based on a dual-tree complex wavelet transform (DTCWT). The Sum-Modified-Laplacian (SML)-based visual contrast and SML are employed to fuse the low- and high-frequency coefficients, respectively, and an initial composited image is obtained. In the final fusion process, the image block residuals technique and consistency verification are used to detect the focusing areas and then a decision map is obtained. The map is used to guide how to achieve the final fused image. The performance of the proposed method was extensively tested on a number of multi-focus images, including no-referenced images, referenced images, and images with different noise levels. The experimental results clearly indicate that the proposed method outperformed various state-of-the-art fusion methods, in terms of both subjective and objective evaluations, and is more suitable for VSNs. PMID:25587878

  4. Dual-tree complex wavelet transform and image block residual-based multi-focus image fusion in visual sensor networks.

    PubMed

    Yang, Yong; Tong, Song; Huang, Shuying; Lin, Pan

    2014-11-26

    This paper presents a novel framework for the fusion of multi-focus images explicitly designed for visual sensor network (VSN) environments. Multi-scale based fusion methods can often obtain fused images with good visual effect. However, because of the defects of the fusion rules, it is almost impossible to completely avoid the loss of useful information in the thus obtained fused images. The proposed fusion scheme can be divided into two processes: initial fusion and final fusion. The initial fusion is based on a dual-tree complex wavelet transform (DTCWT). The Sum-Modified-Laplacian (SML)-based visual contrast and SML are employed to fuse the low- and high-frequency coefficients, respectively, and an initial composited image is obtained. In the final fusion process, the image block residuals technique and consistency verification are used to detect the focusing areas and then a decision map is obtained. The map is used to guide how to achieve the final fused image. The performance of the proposed method was extensively tested on a number of multi-focus images, including no-referenced images, referenced images, and images with different noise levels. The experimental results clearly indicate that the proposed method outperformed various state-of-the-art fusion methods, in terms of both subjective and objective evaluations, and is more suitable for VSNs.

  5. WE-EF-BRD-00: New Developments in Hybrid MR-Treatment: Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2015-06-15

    MRI-guided treatment is a growing area of medicine, particularly in radiotherapy and surgery. The exquisite soft tissue anatomic contrast offered by MRI, along with functional imaging, makes the use of MRI during therapeutic procedures very attractive. Challenging the utility of MRI in the therapy room are many issues including the physics of MRI and the impact on the environment and therapeutic instruments, the impact of the room and instruments on the MRI; safety, space, design and cost. In this session, the applications and challenges of MRI-guided treatment will be described. The session format is: Past, present and future: MRI-guided radiotherapymore » from 2005 to 2025: Jan Lagendijk Battling Maxwell’s equations: Physics challenges and solutions for hybrid MRI systems: Paul Keall I want it now!: Advances in MRI acquisition, reconstruction and the use of priors to enable fast anatomic and physiologic imaging to inform guidance and adaptation decisions: Yanle Hu MR in the OR: The growth and applications of MRI for interventional radiology and surgery: Rebecca Fahrig Learning Objectives: To understand the history and trajectory of MRI-guided radiotherapy To understand the challenges of integrating MR imaging systems with linear accelerators To understand the latest in fast MRI methods to enable the visualisation of anatomy and physiology on radiotherapy treatment timescales To understand the growing role and challenges of MRI for image-guided surgical procedures My disclosures are publicly available and updated at: http://sydney.edu.au/medicine/radiation-physics/about-us/disclosures.php.« less

  6. The MEPUC concept adapts the C-arm fluoroscope to image-guided surgery.

    PubMed

    Suhm, Norbert; Müller, Paul; Bopp, Urs; Messmer, Peter; Regazzoni, Pietro

    2004-06-01

    Image-guided surgery requires surgeons to be able to manipulate the imaging modality themselves and without delay. Intraoperative fluoroscopic imaging does not meet this requirement as the C-arm fluoroscope cannot be operated or positioned by the surgeons themselves. The Motorized Exact Positioning Unit for C-arm (MEPUC) concept aims to optimize the workflow of positioning the C-arm fluoroscope. The hardware component of the MEPUC equips the fluoroscope with electric stepping motors. The software component allows the surgeon to control the fluoroscope's movements. The study presented here showed that translational movements within the x-y plane are most frequently performed when positioning the C-arm fluoroscope. Furthermore, reproducing a former projection was found to be a frequent task during image-guided procedures. In our opinion, the MEPUC concept adapts the fluoroscope to image-guided surgery. The most important improvement being definition of a bidirectional data exchange between the surgeon and the C-arm fluoroscope: positioning data from the surgeon to the C-arm fluoroscope and-subsequently-image information from C-arm fluoroscope to the surgeon.

  7. A haptic device for guide wire in interventional radiology procedures.

    PubMed

    Moix, Thomas; Ilic, Dejan; Bleuler, Hannes; Zoethout, Jurjen

    2006-01-01

    Interventional Radiology (IR) is a minimally invasive procedure where thin tubular instruments, guide wires and catheters, are steered through the patient's vascular system under X-ray imaging. In order to perform these procedures, a radiologist has to be trained to master hand-eye coordination, instrument manipulation and procedure protocols. The existing simulation systems all have major drawbacks: the use of modified instruments, unrealistic insertion lengths, high inertia of the haptic device that creates a noticeably degraded dynamic behavior or excessive friction that is not properly compensated for. In this paper we propose a quality training environment dedicated to IR. The system is composed of a virtual reality (VR) simulation of the patient's anatomy linked to a robotic interface providing haptic force feedback. This paper focuses on the requirements, design and prototyping of a specific haptic interface for guide wires.

  8. The Neural Basis of Mark Making: A Functional MRI Study of Drawing

    PubMed Central

    Yuan, Ye; Brown, Steven

    2014-01-01

    Compared to most other forms of visually-guided motor activity, drawing is unique in that it “leaves a trail behind” in the form of the emanating image. We took advantage of an MRI-compatible drawing tablet in order to examine both the motor production and perceptual emanation of images. Subjects participated in a series of mark making tasks in which they were cued to draw geometric patterns on the tablet's surface. The critical comparison was between when visual feedback was displayed (image generation) versus when it was not (no image generation). This contrast revealed an occipito-parietal stream involved in motion-based perception of the emerging image, including areas V5/MT+, LO, V3A, and the posterior part of the intraparietal sulcus. Interestingly, when subjects passively viewed animations of visual patterns emerging on the projected surface, all of the sensorimotor network involved in drawing was strongly activated, with the exception of the primary motor cortex. These results argue that the origin of the human capacity to draw and write involves not only motor skills for tool use but also motor-sensory links between drawing movements and the visual images that emanate from them in real time. PMID:25271440

  9. Comparison of amplitude-decorrelation, speckle-variance and phase-variance OCT angiography methods for imaging the human retina and choroid

    PubMed Central

    Gorczynska, Iwona; Migacz, Justin V.; Zawadzki, Robert J.; Capps, Arlie G.; Werner, John S.

    2016-01-01

    We compared the performance of three OCT angiography (OCTA) methods: speckle variance, amplitude decorrelation and phase variance for imaging of the human retina and choroid. Two averaging methods, split spectrum and volume averaging, were compared to assess the quality of the OCTA vascular images. All data were acquired using a swept-source OCT system at 1040 nm central wavelength, operating at 100,000 A-scans/s. We performed a quantitative comparison using a contrast-to-noise (CNR) metric to assess the capability of the three methods to visualize the choriocapillaris layer. For evaluation of the static tissue noise suppression in OCTA images we proposed to calculate CNR between the photoreceptor/RPE complex and the choriocapillaris layer. Finally, we demonstrated that implementation of intensity-based OCT imaging and OCT angiography methods allows for visualization of retinal and choroidal vascular layers known from anatomic studies in retinal preparations. OCT projection imaging of data flattened to selected retinal layers was implemented to visualize retinal and choroidal vasculature. User guided vessel tracing was applied to segment the retinal vasculature. The results were visualized in a form of a skeletonized 3D model. PMID:27231598

  10. Clinical implementation of intraoperative cone-beam CT in head and neck surgery

    NASA Astrophysics Data System (ADS)

    Daly, M. J.; Chan, H.; Nithiananthan, S.; Qiu, J.; Barker, E.; Bachar, G.; Dixon, B. J.; Irish, J. C.; Siewerdsen, J. H.

    2011-03-01

    A prototype mobile C-arm for cone-beam CT (CBCT) has been translated to a prospective clinical trial in head and neck surgery. The flat-panel CBCT C-arm was developed in collaboration with Siemens Healthcare, and demonstrates both sub-mm spatial resolution and soft-tissue visibility at low radiation dose (e.g., <1/5th of a typical diagnostic head CT). CBCT images are available ~15 seconds after scan completion (~1 min acquisition) and reviewed at bedside using custom 3D visualization software based on the open-source Image-Guided Surgery Toolkit (IGSTK). The CBCT C-arm has been successfully deployed in 15 head and neck cases and streamlined into the surgical environment using human factors engineering methods and expert feedback from surgeons, nurses, and anesthetists. Intraoperative imaging is implemented in a manner that maintains operating field sterility, reduces image artifacts (e.g., carbon fiber OR table) and minimizes radiation exposure. Image reviews conducted with surgical staff indicate bony detail and soft-tissue visualization sufficient for intraoperative guidance, with additional artifact management (e.g., metal, scatter) promising further improvements. Clinical trial deployment suggests a role for intraoperative CBCT in guiding complex head and neck surgical tasks, including planning mandible and maxilla resection margins, guiding subcranial and endonasal approaches to skull base tumours, and verifying maxillofacial reconstruction alignment. Ongoing translational research into complimentary image-guidance subsystems include novel methods for real-time tool tracking, fusion of endoscopic video and CBCT, and deformable registration of preoperative volumes and planning contours with intraoperative CBCT.

  11. Solar System Visualization (SSV) Project

    NASA Technical Reports Server (NTRS)

    Todd, Jessida L.

    2005-01-01

    The Solar System Visualization (SSV) project aims at enhancing scientific and public understanding through visual representations and modeling procedures. The SSV project's objectives are to (1) create new visualization technologies, (2) organize science observations and models, and (3) visualize science results and mission Plans. The SSV project currently supports the Mars Exploration Rovers (MER) mission, the Mars Reconnaissance Orbiter (MRO), and Cassini. In support of the these missions, the SSV team has produced pan and zoom animations of large mosaics to reveal details of surface features and topography, created 3D animations of science instruments and procedures, formed 3-D anaglyphs from left and right stereo pairs, and animated registered multi-resolution mosaics to provide context for microscopic images.

  12. Multimode intravascular RF coil for MRI-guided interventions.

    PubMed

    Kurpad, Krishna N; Unal, Orhan

    2011-04-01

    To demonstrate the feasibility of using a single intravascular radiofrequency (RF) probe connected to the external magnetic resonance imaging (MRI) system via a single coaxial cable to perform active tip tracking and catheter visualization and high signal-to-noise ratio (SNR) intravascular imaging. A multimode intravascular RF coil was constructed on a 6F balloon catheter and interfaced to a 1.5T MRI scanner via a decoupling circuit. Bench measurements of coil impedances were followed by imaging experiments in saline and phantoms. The multimode coil behaves as an inductively coupled transmit coil. The forward-looking capability of 6 mm was measured. A greater than 3-fold increase in SNR compared to conventional imaging using optimized external coil was demonstrated. Simultaneous active tip tracking and catheter visualization was demonstrated. It is feasible to perform 1) active tip tracking, 2) catheter visualization, and 3) high SNR imaging using a single multimode intravascular RF coil that is connected to the external system via a single coaxial cable. Copyright © 2011 Wiley-Liss, Inc.

  13. High-quality compressive ghost imaging

    NASA Astrophysics Data System (ADS)

    Huang, Heyan; Zhou, Cheng; Tian, Tian; Liu, Dongqi; Song, Lijun

    2018-04-01

    We propose a high-quality compressive ghost imaging method based on projected Landweber regularization and guided filter, which effectively reduce the undersampling noise and improve the resolution. In our scheme, the original object is reconstructed by decomposing of regularization and denoising steps instead of solving a minimization problem in compressive reconstruction process. The simulation and experimental results show that our method can obtain high ghost imaging quality in terms of PSNR and visual observation.

  14. An Active System for Visually-Guided Reaching in 3D across Binocular Fixations

    PubMed Central

    2014-01-01

    Based on the importance of relative disparity between objects for accurate hand-eye coordination, this paper presents a biological approach inspired by the cortical neural architecture. So, the motor information is coded in egocentric coordinates obtained from the allocentric representation of the space (in terms of disparity) generated from the egocentric representation of the visual information (image coordinates). In that way, the different aspects of the visuomotor coordination are integrated: an active vision system, composed of two vergent cameras; a module for the 2D binocular disparity estimation based on a local estimation of phase differences performed through a bank of Gabor filters; and a robotic actuator to perform the corresponding tasks (visually-guided reaching). The approach's performance is evaluated through experiments on both simulated and real data. PMID:24672295

  15. Statistical Analysis of Interactive Surgical Planning Using Shape Descriptors in Mandibular Reconstruction with Fibular Segments

    PubMed Central

    2016-01-01

    This study was performed to quantitatively analyze medical knowledge of, and experience with, decision-making in preoperative virtual planning of mandibular reconstruction. Three shape descriptors were designed to evaluate local differences between reconstructed mandibles and patients’ original mandibles. We targeted an asymmetrical, wide range of cutting areas including the mandibular sidepiece, and defined a unique three-dimensional coordinate system for each mandibular image. The generalized algorithms for computing the shape descriptors were integrated into interactive planning software, where the user can refine the preoperative plan using the spatial map of the local shape distance as a visual guide. A retrospective study was conducted with two oral surgeons and two dental technicians using the developed software. The obtained 120 reconstruction plans show that the participants preferred a moderate shape distance rather than optimization to the smallest. We observed that a visually plausible shape could be obtained when considering specific anatomical features (e.g., mental foramen. mandibular midline). The proposed descriptors can be used to multilaterally evaluate reconstruction plans and systematically learn surgical procedures. PMID:27583465

  16. Electromagnetic navigation versus fluoroscopy in aortic endovascular procedures: a phantom study.

    PubMed

    Tystad Lund, Kjetil; Tangen, Geir Arne; Manstad-Hulaas, Frode

    2017-01-01

    To explore the possible benefits of electromagnetic (EM) navigation versus conventional fluoroscopy during abdominal aortic endovascular procedures. The study was performed on a phantom representing the abdominal aorta. Intraoperative cone beam computed tomography (CBCT) of the phantom was acquired and merged with a preoperative multidetector CT (MDCT). The CBCT was performed with a reference plate fixed to the phantom that, after merging the CBCT with the MDCT, facilitated registration of the MDCT volume with the EM space. An EM field generator was stationed near the phantom. Navigation software was used to display EM-tracked instruments within the 3D image volume. Fluoroscopy was performed using a C-arm system. Five operators performed a series of renal artery cannulations using modified instruments, alternatingly using fluoroscopy or EM navigation as the sole guidance method. Cannulation durations and associated radiation dosages were noted along with the number of cannulations complicated by loss of guidewire insertion. A total of 120 cannulations were performed. The median cannulation durations were 41.5 and 34.5 s for the fluoroscopy- and EM-guided cannulations, respectively. No significant difference in cannulation duration was found between the two modalities (p = 0.736). Only EM navigation showed a significant reduction in cannulation duration in the latter half of its cannulation series compared with the first half (p = 0.004). The median dose area product for fluoroscopy was 0.0836 [Formula: see text]. EM-guided cannulations required a one-time CBCT dosage of 3.0278 [Formula: see text]. Three EM-guided and zero fluoroscopy-guided cannulations experienced loss of guidewire insertion. Our findings indicate that EM navigation is not inferior to fluoroscopy in terms of the ability to guide endovascular interventions. Its utilization may be of particular interest in complex interventions where adequate visualization or minimal use of contrast agents is critical. In vivo studies featuring an optimized implementation of EM navigation should be conducted.

  17. Ultrasound-Guided Intermediate Site Greater Occipital Nerve Infiltration: A Technical Feasibility Study.

    PubMed

    Zipfel, Jonathan; Kastler, Adrian; Tatu, Laurent; Behr, Julien; Kechidi, Rachid; Kastler, Bruno

    2016-01-01

    Two studies recently reported that computed tomography (CT) guided infiltration of the greater occipital nerve at its intermediate site allows a high efficacy rate with long-lasting pain relief following procedure in occipital neuralgia and in various craniofacial pain syndromes. The purpose of our study was to evaluate the technical feasibility and safety of ultrasound-guided intermediate site greater occipital nerve infiltration. Retrospective study. This study was conducted at the imaging department of a 1,409 bed university hospital. Local institutional review board approval was obtained and written consent was waived. In this retrospective study, 12 patients suffering from refractory occipital neuralgia or craniofacial pain syndromes were included between April and October 2014. They underwent a total of 21 ultrasound-guided infiltrations. Infiltration of the greater occipital nerve was performed at the intermediate site of the greater occipital nerve, at its first bend between obliqus capitis inferior and semispinalis capitis muscles with local anestetics and cortivazol. Technical success was defined as satisfactory diffusion of added iodinated contrast media in the fatty space between these muscles depicted on control CT scan. We also reported first data of immediate block test efficacy and initial clinical efficacy at 7 days, one month, and 3 months, defined by a decrease of at least 50% of visual analog scale (VAS) scores. Technical success rate was 95.24%. Patients suffered from right unilateral occipital neuralgia in 3 cases, left unilateral occipital neuralgia in 2 cases, bilateral occipital neuralgia in 2 cases, migraine in one case, cervicogenic headache in one case, tension-type headache in 2 cases, and cluster headache in one case. Block test efficacy was found in 93.3% (14/15) cases. Clinical efficacy was found in 80% of cases at 7 days, in 66.7% of cases at one month and in 60% of cases at 3 months. No major complications were noted. Some of the limitations of our study include that it represents a single institution. The low number of infiltrations included in this study, for this guidance procedure, is another bias. This ultrasound-guided infiltration technique appears to be feasible, safe, non-ionizing, and fast when targeting the greater occipital nerve in its intermediate portion. This imaging guidance modality should be used in routine clinical practice. Greater occipital nerve, infiltration, ultrasound guidance, corticosteroids, occipital neuralgia, craniofacial pain syndrome.

  18. Augmented Endoscopic Images Overlaying Shape Changes in Bone Cutting Procedures.

    PubMed

    Nakao, Megumi; Endo, Shota; Nakao, Shinichi; Yoshida, Munehito; Matsuda, Tetsuya

    2016-01-01

    In microendoscopic discectomy for spinal disorders, bone cutting procedures are performed in tight spaces while observing a small portion of the target structures. Although optical tracking systems are able to measure the tip of the surgical tool during surgery, the poor shape information available during surgery makes accurate cutting difficult, even if preoperative computed tomography and magnetic resonance images are used for reference. Shape estimation and visualization of the target structures are essential for accurate cutting. However, time-varying shape changes during cutting procedures are still challenging issues for intraoperative navigation. This paper introduces a concept of endoscopic image augmentation that overlays shape changes to support bone cutting procedures. This framework handles the history of the location of the measured drill tip as a volume label and visualizes the remains to be cut overlaid on the endoscopic image in real time. A cutting experiment was performed with volunteers, and the feasibility of this concept was examined using a clinical navigation system. The efficacy of the cutting aid was evaluated with respect to the shape similarity, total moved distance of a cutting tool, and required cutting time. The results of the experiments showed that cutting performance was significantly improved by the proposed framework.

  19. Magnetic resonance imaging-radioguided occult lesion localization (ROLL) in breast cancer using Tc-99m macro-aggregated albumin and distilled water control.

    PubMed

    Philadelpho Arantes Pereira, Fernanda; Martins, Gabriela; Gregorio Calas, Maria Julia; Fonseca Torres de Oliveira, Maria Veronica; Gasparetto, Emerson Leandro; Barbosa da Fonseca, Lea Mirian

    2013-09-18

    Magnetic resonance imaging (MRI) guided wire localization presents several challenges apart from the technical difficulties. An alternative to this conventional localization method using a wire is the radio-guided occult lesion localization (ROLL), more related to safe surgical margins and reductions in excision volume. The purpose of this study was to establish a safe and reliable magnetic resonance imaging-radioguided occult lesion localization (MRI-ROLL) technique and to report our initial experience with the localization of nonpalpable breast lesions only observed on MRI. Sixteen women (mean age 53.2 years) with 17 occult breast lesions underwent radio-guided localization in a 1.5-T MR system using a grid-localizing system. All patients had a diagnostic MRI performed prior to the procedure. An intralesional injection of Technetium-99m macro-aggregated albumin followed by distilled water was performed. After the procedure, scintigraphy was obtained. Surgical resection was performed with the help of a gamma detector probe. The lesion histopathology and imaging concordance; the procedure's positive predictive value (PPV), duration time, complications, and accuracy; and the rate of exactly excised lesions evaluated with MRI six months after the surgery were assessed. One lesion in one patient had to be excluded because the radioactive substance came back after the injection, requiring a wire placement. Of the remaining cases, there were four malignant lesions, nine benign lesions, and three high-risk lesions. Surgical histopathology and imaging findings were considered concordant in all benign and high-risk cases. The PPV of MRI-ROLL was greater if the indication for the initial MR examination was active breast cancer. The median procedure duration time was 26 minutes, and all included procedures were defined as accurate. The exact and complete lesion removal was confirmed in all (100%) patients who underwent six-month postoperative MRI (50%). MRI-ROLL offers a precise, technically feasible, safe, and rapid means for performing preoperative MRI localizations in the breast.

  20. Visual control of robots using range images.

    PubMed

    Pomares, Jorge; Gil, Pablo; Torres, Fernando

    2010-01-01

    In the last years, 3D-vision systems based on the time-of-flight (ToF) principle have gained more importance in order to obtain 3D information from the workspace. In this paper, an analysis of the use of 3D ToF cameras to guide a robot arm is performed. To do so, an adaptive method to simultaneous visual servo control and camera calibration is presented. Using this method a robot arm is guided by using range information obtained from a ToF camera. Furthermore, the self-calibration method obtains the adequate integration time to be used by the range camera in order to precisely determine the depth information.

  1. Fast 3-T MR-guided transrectal prostate biopsy using an in-room tablet device for needle guide alignment: a feasibility study.

    PubMed

    Overduin, Christiaan G; Heidkamp, Jan; Rothgang, Eva; Barentsz, Jelle O; de Lange, Frank; Fütterer, Jurgen J

    2018-05-22

    To assess the feasibility of adding a tablet device inside the scanner room to assist needle-guide alignment during magnetic resonance (MR)-guided transrectal prostate biopsy. Twenty patients with one cancer-suspicious region (CSR) with PI-RADS score ≥ 4 on diagnostic multiparametric MRI were prospectively enrolled. Two orthogonal scan planes of an MR fluoroscopy sequence (~3 images/s) were aligned to the CSR and needle-guide pivoting point. Targeting was achieved by manipulating the needle-guide under MR fluoroscopy feedback on the in-room tablet device. Technical feasibility and targeting success were assessed. Complications and biopsy procedure times were also recorded. Needle-guide alignment with the in-room tablet device was technically successful in all patients and allowed sampling after a single alignment step in 19/20 (95%) CSRs (median size 14 mm, range: 4-45). Biopsy cores contained cancer in 18/20 patients. There were no per-procedural or post-biopsy complications. Using the tablet device, the mean time to first biopsy was 5.8 ± 1.0 min and the mean total procedure time was 23.7 ± 4.1 min. Use of an in-room tablet device to assist needle-guide alignment was feasible and safe during MR-guided transrectal prostate biopsy. Initial experience indicates potential for procedure time reduction. • Performing MR-guided prostate biopsy using an in-room tablet device is feasible. • CSRs could be sampled after a single alignment step in 19/20 patients. • The mean procedure time for biopsy with the tablet device was 23.7 min.

  2. Usefulness of myocardial parametric imaging to evaluate myocardial viability in experimental and in clinical studies.

    PubMed

    Korosoglou, G; Hansen, A; Bekeredjian, R; Filusch, A; Hardt, S; Wolf, D; Schellberg, D; Katus, H A; Kuecherer, H

    2006-03-01

    To evaluate whether myocardial parametric imaging (MPI) is superior to visual assessment for the evaluation of myocardial viability. Myocardial contrast echocardiography (MCE) was assessed in 11 pigs before, during, and after left anterior descending coronary artery occlusion and in 32 patients with ischaemic heart disease by using intravenous SonoVue administration. In experimental studies perfusion defect area assessment by MPI was compared with visually guided perfusion defect planimetry. Histological assessment of necrotic tissue was the standard reference. In clinical studies viability was assessed on a segmental level by (1) visual analysis of myocardial opacification; (2) quantitative estimation of myocardial blood flow in regions of interest; and (3) MPI. Functional recovery between three and six months after revascularisation was the standard reference. In experimental studies, compared with visually guided perfusion defect planimetry, planimetric assessment of infarct size by MPI correlated more significantly with histology (r2 = 0.92 versus r2 = 0.56) and had a lower intraobserver variability (4% v 15%, p < 0.05). In clinical studies, MPI had higher specificity (66% v 43%, p < 0.05) than visual MCE and good accuracy (81%) for viability detection. It was less time consuming (3.4 (1.6) v 9.2 (2.4) minutes per image, p < 0.05) than quantitative blood flow estimation by regions of interest and increased the agreement between observers interpreting myocardial perfusion (kappa = 0.87 v kappa = 0.75, p < 0.05). MPI is useful for the evaluation of myocardial viability both in animals and in patients. It is less time consuming than quantification analysis by regions of interest and less observer dependent than visual analysis. Thus, strategies incorporating this technique may be valuable for the evaluation of myocardial viability in clinical routine.

  3. Autonomous Visual Navigation of an Indoor Environment Using a Parsimonious, Insect Inspired Familiarity Algorithm

    PubMed Central

    Brayfield, Brad P.

    2016-01-01

    The navigation of bees and ants from hive to food and back has captivated people for more than a century. Recently, the Navigation by Scene Familiarity Hypothesis (NSFH) has been proposed as a parsimonious approach that is congruent with the limited neural elements of these insects’ brains. In the NSFH approach, an agent completes an initial training excursion, storing images along the way. To retrace the path, the agent scans the area and compares the current scenes to those previously experienced. By turning and moving to minimize the pixel-by-pixel differences between encountered and stored scenes, the agent is guided along the path without having memorized the sequence. An important premise of the NSFH is that the visual information of the environment is adequate to guide navigation without aliasing. Here we demonstrate that an image landscape of an indoor setting possesses ample navigational information. We produced a visual landscape of our laboratory and part of the adjoining corridor consisting of 2816 panoramic snapshots arranged in a grid at 12.7-cm centers. We show that pixel-by-pixel comparisons of these images yield robust translational and rotational visual information. We also produced a simple algorithm that tracks previously experienced routes within our lab based on an insect-inspired scene familiarity approach and demonstrate that adequate visual information exists for an agent to retrace complex training routes, including those where the path’s end is not visible from its origin. We used this landscape to systematically test the interplay of sensor morphology, angles of inspection, and similarity threshold with the recapitulation performance of the agent. Finally, we compared the relative information content and chance of aliasing within our visually rich laboratory landscape to scenes acquired from indoor corridors with more repetitive scenery. PMID:27119720

  4. Pulsed-light imaging for fluorescence guided surgery under normal room lighting.

    PubMed

    Sexton, Kristian; Davis, Scott C; McClatchy, David; Valdes, Pablo A; Kanick, Stephen C; Paulsen, Keith D; Roberts, David W; Pogue, Brian W

    2013-09-01

    Fluorescence guided surgery (FGS) is an emerging technology that has demonstrated improved surgical outcomes. However, dim lighting conditions required by current FGS systems are disruptive to standard surgical workflow. We present a novel FGS system capable of imaging fluorescence under normal room light by using pulsed excitation and gated acquisition. Images from tissue-simulating phantoms confirm visual detection down to 0.25 μM of protoporphyrin IX under 125 μW/cm2 of ambient light, more than an order of magnitude lower than that measured with the Zeiss Pentero in the dark. Resection of orthotopic brain tumors in mice also suggests that the pulsed-light system provides superior sensitivity in vivo.

  5. Pulsed-light imaging for fluorescence guided surgery under normal room lighting

    PubMed Central

    Sexton, Kristian; Davis, Scott C.; McClatchy, David; Valdes, Pablo A.; Kanick, Stephen C.; Paulsen, Keith D.; Roberts, David W.; Pogue, Brian W.

    2013-01-01

    Fluorescence guided surgery (FGS) is an emerging technology that has demonstrated improved surgical outcomes. However, dim lighting conditions required bycurrent FGS systems are disruptive to standard surgical workflow. We present a novel FGS system capable of imaging fluorescence under normal room lightby using pulsed excitation and gated acquisition. Images from tissue-simulating phantoms confirm visual detection down to 0.25 μM of protopor-phyrin IX under 125 μW/cm2 of ambient light, more than an order of magnitude lower than that measured with the Zeiss Pentero in the dark. Resection of orthotopic brain tumors in mice also suggests that the pulsed-light system provides superior sensitivity in vivo. PMID:23988926

  6. FUNCTIONAL NANOPARTICLES FOR MOLECULAR IMAGING GUIDED GENE DELIVERY

    PubMed Central

    Liu, Gang; Swierczewska, Magdalena; Lee, Seulki; Chen, Xiaoyuan

    2010-01-01

    Gene therapy has great potential to bring tremendous changes in treatment of various diseases and disorders. However, one of the impediments to successful gene therapy is the inefficient delivery of genes to target tissues and the inability to monitor delivery of genes and therapeutic responses at the targeted site. The emergence of molecular imaging strategies has been pivotal in optimizing gene therapy; since it can allow us to evaluate the effectiveness of gene delivery noninvasively and spatiotemporally. Due to the unique physiochemical properties of nanomaterials, numerous functional nanoparticles show promise in accomplishing gene delivery with the necessary feature of visualizing the delivery. In this review, recent developments of nanoparticles for molecular imaging guided gene delivery are summarized. PMID:22473061

  7. Retinal Image Simulation of Subjective Refraction Techniques.

    PubMed

    Perches, Sara; Collados, M Victoria; Ares, Jorge

    2016-01-01

    Refraction techniques make it possible to determine the most appropriate sphero-cylindrical lens prescription to achieve the best possible visual quality. Among these techniques, subjective refraction (i.e., patient's response-guided refraction) is the most commonly used approach. In this context, this paper's main goal is to present a simulation software that implements in a virtual manner various subjective-refraction techniques--including Jackson's Cross-Cylinder test (JCC)--relying all on the observation of computer-generated retinal images. This software has also been used to evaluate visual quality when the JCC test is performed in multifocal-contact-lens wearers. The results reveal this software's usefulness to simulate the retinal image quality that a particular visual compensation provides. Moreover, it can help to gain a deeper insight and to improve existing refraction techniques and it can be used for simulated training.

  8. Outcome of percutaneous continuous drainage of psoas abscess: A clinically guided technique.

    PubMed

    Dave, Bharat R; Kurupati, Ranganatha Babu; Shah, Dipak; Degulamadi, Devanand; Borgohain, Nitu; Krishnan, Ajay

    2014-01-01

    Percutaneous aspiration of abscesses under ultrasonography (USG) and computer tomography (CT) scan has been well described. With recurrence rate reported as high as 66%. The open drainage and percutaneous continuous drainage (PCD) has reduced the recurrence rate. The disadvantage of PCD under CT is radiation hazard and problems of asepsis. Hence a technique of clinically guided percutaneous continuous drainage of the psoas abscess without real-time imaging overcomes these problems. We describe clinically guided PCD of psoas abscess and its outcome. Twenty-nine patients with dorsolumbar spondylodiscitis without gross neural deficit with psoas abscess of size >5 cm were selected for PCD. It was done as a day care procedure under local anesthesia. Sequentially, aspiration followed by guide pin-guided trocar and catheter insertion was done without image guidance. Culture sensitivity was done and chemotherapy initiated and catheter kept till the drainage was <10 ml for 48 hours. Outcome assessment was done with relief of pain, successful abscess drainage and ODI (Oswestry Disability Index) score at 2 years. PCD was successful in all cases. Back and radicular pain improved in all cases. Average procedure time was 24.30 minutes, drain output was 234.40 ml, and the drainage duration was 7.90 days. One patient required surgical stabilisation due to progression of the spondylodiscitis resulting in instability inspite of successful drainage of abscess. Problems with the procedure were noticed in six patients. Multiple attempts (n = 2), persistent discharge (n = 1) for 2 weeks, blocked catheter (n = 2) and catheter pull out (n = 1) occurred with no effect on the outcome. The average ODI score improved from 62.47 to 5.51 at 2 years. Clinically guided PCD is an efficient, safe and easy procedure in drainage of psoas abscess.

  9. Investigating Surface and Near-Surface Bushfire Fuel Attributes: A Comparison between Visual Assessments and Image-Based Point Clouds

    PubMed Central

    Spits, Christine; Wallace, Luke; Reinke, Karin

    2017-01-01

    Visual assessment, following guides such as the Overall Fuel Hazard Assessment Guide (OFHAG), is a common approach for assessing the structure and hazard of varying bushfire fuel layers. Visual assessments can be vulnerable to imprecision due to subjectivity between assessors, while emerging techniques such as image-based point clouds can offer land managers potentially more repeatable descriptions of fuel structure. This study compared the variability of estimates of surface and near-surface fuel attributes generated by eight assessment teams using the OFHAG and Fuels3D, a smartphone method utilising image-based point clouds, within three assessment plots in an Australian lowland forest. Surface fuel hazard scores derived from underpinning attributes were also assessed. Overall, this study found considerable variability between teams on most visually assessed variables, resulting in inconsistent hazard scores. Variability was observed within point cloud estimates but was, however, on average two to eight times less than that seen in visual estimates, indicating greater consistency and repeatability of this method. It is proposed that while variability within the Fuels3D method may be overcome through improved methods and equipment, inconsistencies in the OFHAG are likely due to the inherent subjectivity between assessors, which may be more difficult to overcome. This study demonstrates the capability of the Fuels3D method to efficiently and consistently collect data on fuel hazard and structure, and, as such, this method shows potential for use in fire management practices where accurate and reliable data is essential. PMID:28425957

  10. Drawing enhances cross-modal memory plasticity in the human brain: a case study in a totally blind adult

    PubMed Central

    Likova, Lora T.

    2012-01-01

    In a memory-guided drawing task under blindfolded conditions, we have recently used functional Magnetic Resonance Imaging (fMRI) to demonstrate that the primary visual cortex (V1) may operate as the visuo-spatial buffer, or “sketchpad,” for working memory. The results implied, however, a modality-independent or amodal form of its operation. In the present study, to validate the role of V1 in non-visual memory, we eliminated not only the visual input but all levels of visual processing by replicating the paradigm in a congenitally blind individual. Our novel Cognitive-Kinesthetic method was used to train this totally blind subject to draw complex images guided solely by tactile memory. Control tasks of tactile exploration and memorization of the image to be drawn, and memory-free scribbling were also included. FMRI was run before training and after training. Remarkably, V1 of this congenitally blind individual, which before training exhibited noisy, immature, and non-specific responses, after training produced full-fledged response time-courses specific to the tactile-memory drawing task. The results reveal the operation of a rapid training-based plasticity mechanism that recruits the resources of V1 in the process of learning to draw. The learning paradigm allowed us to investigate for the first time the evolution of plastic re-assignment in V1 in a congenitally blind subject. These findings are consistent with a non-visual memory involvement of V1, and specifically imply that the observed cortical reorganization can be empowered by the process of learning to draw. PMID:22593738

  11. Drawing enhances cross-modal memory plasticity in the human brain: a case study in a totally blind adult.

    PubMed

    Likova, Lora T

    2012-01-01

    In a memory-guided drawing task under blindfolded conditions, we have recently used functional Magnetic Resonance Imaging (fMRI) to demonstrate that the primary visual cortex (V1) may operate as the visuo-spatial buffer, or "sketchpad," for working memory. The results implied, however, a modality-independent or amodal form of its operation. In the present study, to validate the role of V1 in non-visual memory, we eliminated not only the visual input but all levels of visual processing by replicating the paradigm in a congenitally blind individual. Our novel Cognitive-Kinesthetic method was used to train this totally blind subject to draw complex images guided solely by tactile memory. Control tasks of tactile exploration and memorization of the image to be drawn, and memory-free scribbling were also included. FMRI was run before training and after training. Remarkably, V1 of this congenitally blind individual, which before training exhibited noisy, immature, and non-specific responses, after training produced full-fledged response time-courses specific to the tactile-memory drawing task. The results reveal the operation of a rapid training-based plasticity mechanism that recruits the resources of V1 in the process of learning to draw. The learning paradigm allowed us to investigate for the first time the evolution of plastic re-assignment in V1 in a congenitally blind subject. These findings are consistent with a non-visual memory involvement of V1, and specifically imply that the observed cortical reorganization can be empowered by the process of learning to draw.

  12. Image fusion-guided portal vein puncture during transjugular intrahepatic portosystemic shunt placement.

    PubMed

    Rouabah, K; Varoquaux, A; Caporossi, J M; Louis, G; Jacquier, A; Bartoli, J M; Moulin, G; Vidal, V

    2016-11-01

    The purpose of this study was to assess the feasibility and utility of image fusion (Easy-TIPS) obtained from pre-procedure CT angiography and per-procedure real-time fluoroscopy for portal vein puncture during transjugular intrahepatic portosystemic shunt (TIPS) placement. Eighteen patients (15 men, 3 women) with a mean age of 63 years (range: 48-81 years; median age, 65 years) were included in the study. All patients underwent TIPS placement by two groups of radiologists (one group with radiologists of an experience<3 years and one with an experience≥3 years) using fusion imaging obtained from three-dimensional computed tomography angiography of the portal vein and real-time fluoroscopic images of the portal vein. Image fusion was used to guide the portal vein puncture during TIPS placement. At the end of the procedure, the interventional radiologists evaluated the utility of fusion imaging for portal vein puncture during TIPS placement. Mismatch between three-dimensional computed tomography angiography and real-time fluoroscopic images of the portal vein on image fusion was quantitatively analyzed. Posttreatment CT time, number of the puncture attempts, total radiation exposure and radiation from the retrograde portography were also recorded. Image fusion was considered useful for portal vein puncture in 13/18 TIPS procedures (72%). The mean posttreatment time to obtain fusion images was 16.4minutes. 3D volume rendered CT angiography images was strictly superimposed on direct portography in 10/18 procedures (56%). The mismatch mean value was 0.69cm in height and 0.28cm laterally. A mean number of 4.6 portal vein puncture attempts was made. Eight patients required less than three attempts. The mean radiation dose from retrograde portography was 421.2dGy.cm 2 , corresponding to a mean additional exposure of 19%. Fusion imaging resulting from image fusion from pre-procedural CT angiography is feasible, safe and makes portal puncture easier during TIPS placement. Copyright © 2016 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  13. Concepts and Preliminary Data Toward the Realization of Image-guided Liver Surgery

    PubMed Central

    Cash, David M.; Miga, Michael I.; Glasgow, Sean C.; Dawant, Benoit M.; Clements, Logan W.; Cao, Zhujiang; Galloway, Robert L.; Chapman, William C.

    2013-01-01

    Image-guided surgery provides navigational assistance to the surgeon by displaying the surgical probe position on a set of preoperative tomograms in real time. In this study, the feasibility of implementing image-guided surgery concepts into liver surgery was examined during eight hepatic resection procedures. Preoperative tomographic image data were acquired and processed. Accompanying intraoperative data on liver shape and position were obtained through optically tracked probes and laser range scanning technology. The preoperative and intraoperative representations of the liver surface were aligned using the iterative closest point surface matching algorithm. Surface registrations resulted in mean residual errors from 2 to 6 mm, with errors of target surface regions being below a stated goal of 1 cm. Issues affecting registration accuracy include liver motion due to respiration, the quality of the intraoperative surface data, and intraoperative organ deformation. Respiratory motion was quantified during the procedures as cyclical, primarily along the cranial–caudal direction. The resulting registrations were more robust and accurate when using laser range scanning to rapidly acquire thousands of points on the liver surface and when capturing unique geometric regions on the liver surface, such as the inferior edge. Finally, finite element models recovered much of the observed intraoperative deformation, further decreasing errors in the registration. Image-guided liver surgery has shown the potential to provide surgeons with important navigation aids that could increase the accuracy of targeting lesions and the number of patients eligible for surgical resection. PMID:17458587

  14. Automated dental implantation using image-guided robotics: registration results.

    PubMed

    Sun, Xiaoyan; McKenzie, Frederic D; Bawab, Sebastian; Li, Jiang; Yoon, Yongki; Huang, Jen-K

    2011-09-01

    One of the most important factors affecting the outcome of dental implantation is the accurate insertion of the implant into the patient's jaw bone, which requires a high degree of anatomical accuracy. With the accuracy and stability of robots, image-guided robotics is expected to provide more reliable and successful outcomes for dental implantation. Here, we proposed the use of a robot for drilling the implant site in preparation for the insertion of the implant. An image-guided robotic system for automated dental implantation is described in this paper. Patient-specific 3D models are reconstructed from preoperative Cone-beam CT images, and implantation planning is performed with these virtual models. A two-step registration procedure is applied to transform the preoperative plan of the implant insertion into intra-operative operations of the robot with the help of a Coordinate Measurement Machine (CMM). Experiments are carried out with a phantom that is generated from the patient-specific 3D model. Fiducial Registration Error (FRE) and Target Registration Error (TRE) values are calculated to evaluate the accuracy of the registration procedure. FRE values are less than 0.30 mm. Final TRE values after the two-step registration are 1.42 ± 0.70 mm (N = 5). The registration results of an automated dental implantation system using image-guided robotics are reported in this paper. Phantom experiments show that the practice of robot in the dental implantation is feasible and the system accuracy is comparable to other similar systems for dental implantation.

  15. Percutaneous Management of Accidentally Retained Foreign Bodies During Image-Guided Non-vascular Procedures: Novel Technique Using a Large-Bore Biopsy System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cazzato, Roberto Luigi, E-mail: gigicazzato@hotmail.it; Garnon, Julien, E-mail: juleiengarnon@gmail.com; Ramamurthy, Nitin, E-mail: nitin-ramamurthy@hotmail.com

    ObjectiveTo describe a novel percutaneous image-guided technique using a large-bore biopsy system to retrieve foreign bodies (FBs) accidentally retained during non-vascular interventional procedures.Materials and MethodsBetween May 2013 and October 2015, five patients underwent percutaneous retrieval of five iatrogenic FBs, including a biopsy needle tip in the femoral head following osteoblastoma biopsy and radiofrequency ablation (RFA); a co-axial needle shaft within a giant desmoid tumour following cryoablation; and three post-vertebroplasty cement tails within paraspinal muscles. All FBs were retrieved immediately following original procedures under local or general anaesthesia, using combined computed tomography (CT) and fluoroscopic guidance. The basic technique involved positioningmore » a 6G trocar sleeve around the FB long axis and co-axially advancing an 8G biopsy needle to retrieve the FB within the biopsy core. Retrospective chart review facilitated analysis of procedures, FBs, technical success, and complications.ResultsMean FB size was 23 mm (range 8–74 mm). Four FBs were located within 10 mm of non-vascular significant anatomic structures. The basic technique was successful in 3 cases; 2 cases required technical modifications including using a stiff guide-wire to facilitate retrieval in the case of the post-cryoablation FB; and using the central mandrin of the 6G trocar to push a cement tract back into an augmented vertebra when initial retrieval failed. Overall technical success (FB retrieval or removal to non-hazardous location) was 100 %, with no complications.ConclusionPercutaneous image-guided retrieval of iatrogenic FBs using a large-bore biopsy system is a feasible, safe, effective, and versatile technique, with potential advantages over existing methods.« less

  16. A comparison of line enhancement techniques: applications to guide-wire detection and respiratory motion tracking

    NASA Astrophysics Data System (ADS)

    Bismuth, Vincent; Vancamberg, Laurence; Gorges, Sébastien

    2009-02-01

    During interventional radiology procedures, guide-wires are usually inserted into the patients vascular tree for diagnosis or healing purpose. These procedures are monitored with an Xray interventional system providing images of the interventional devices navigating through the patient's body. The automatic detection of such tools by image processing means has gained maturity over the past years and enables applications ranging from image enhancement to multimodal image fusion. Sophisticated detection methods are emerging, which rely on a variety of device enhancement techniques. In this article we reviewed and classified these techniques into three families. We chose a state of the art approach in each of them and built a rigorous framework to compare their detection capability and their computational complexity. Through simulations and the intensive use of ROC curves we demonstrated that the Hessian based methods are the most robust to strong curvature of the devices and that the family of rotated filters technique is the most suited for detecting low CNR and low curvature devices. The steerable filter approach demonstrated less interesting detection capabilities and appears to be the most expensive one to compute. Finally we demonstrated the interest of automatic guide-wire detection on a clinical topic: the compensation of respiratory motion in multimodal image fusion.

  17. Near-infrared (NIR) fluorescence imaging of head and neck squamous cell carcinoma for fluorescence-guided surgery (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Moore, Lindsay; Warram, Jason M.; de Boer, Esther; Carroll, William R.; Morlandt, Anthony; Withrow, Kirk P.; Rosenthal, Eben L.

    2016-03-01

    During fluorescence-guided surgery, a cancer-specific optical probe is injected and visualized using a compatible device intraoperatively to provide visual contrast between diseased and normal tissues to maximize resection of cancer and minimize the resection of precious adjacent normal tissues. Six patients with squamous cell carcinomas of the head and neck region (oral cavity (n=4) or cutaneous (n=2)) were injected with an EGFR-targeting antibody (Cetuximab) conjugated to a near-infrared (NIR) fluorescent dye (IRDye800) 3, 4, or 7 days prior to surgical resection of the cancer. Each patient's tumor was then imaged using a commercially available, open-field NIR fluorescence imaging device each day prior to surgery, intraoperatively, and post-operatively. The mean fluorescence intensity (MFI) of the tumor was calculated for each specimen at each imaging time point. Adjacent normal tissue served as an internal anatomic control for each patient to establish a patient-matched "background" fluorescence. Resected tissues were also imaged using a closed-field NIR imaging device. Tumor to background ratios (TBRs) were calculated for each patient using both devices. Fluorescence histology was correlated with traditional pathology assessment to verify the specificity of antibody-dye conjugate binding. Peak TBRs using the open-field device ranged from 2.2 to 11.3, with an average TBR of 4.9. Peak TBRs were achieved between days 1 and 4. This study demonstrated that a commercially available NIR imaging device suited for intraoperative and clinical use can successfully be used with a fluorescently-labeled dye to delineate between diseased and normal tissue in this single cohort human study, illuminated the potential for its use in fluoresence-guided surgery.

  18. Novel Image-Guided Management of a Uterine Arteriovenous Malformation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Przybojewski, Stefan J., E-mail: drstefanp@hotmail.com; Sadler, David J.

    The investigators present a novel image-guided embolization, not previously described, of a uterine arteriovenous malformation (AVM) resistant to endovascular management. The uterus was exposed surgically, and Histoacryl (Braun, Fulda, Germany) was injected directly into the nidus using ultrasound guidance and fluoroscopy. The patient had a successful full-term pregnancy after this procedure. This technique may be a useful alternative management strategy in patients with uterine AVM who fail traditional endovascular embolization and who still desire fertility.

  19. Methods for multiple-telescope beam imaging and guiding in the near-infrared

    NASA Astrophysics Data System (ADS)

    Anugu, N.; Amorim, A.; Gordo, P.; Eisenhauer, F.; Pfuhl, O.; Haug, M.; Wieprecht, E.; Wiezorrek, E.; Lima, J.; Perrin, G.; Brandner, W.; Straubmeier, C.; Le Bouquin, J.-B.; Garcia, P. J. V.

    2018-05-01

    Atmospheric turbulence and precise measurement of the astrometric baseline vector between any two telescopes are two major challenges in implementing phase-referenced interferometric astrometry and imaging. They limit the performance of a fibre-fed interferometer by degrading the instrument sensitivity and the precision of astrometric measurements and by introducing image reconstruction errors due to inaccurate phases. A multiple-beam acquisition and guiding camera was built to meet these challenges for a recently commissioned four-beam combiner instrument, GRAVITY, at the European Southern Observatory Very Large Telescope Interferometer. For each telescope beam, it measures (a) field tip-tilts by imaging stars in the sky, (b) telescope pupil shifts by imaging pupil reference laser beacons installed on each telescope using a 2 × 2 lenslet and (c) higher-order aberrations using a 9 × 9 Shack-Hartmann. The telescope pupils are imaged to provide visual monitoring while observing. These measurements enable active field and pupil guiding by actuating a train of tip-tilt mirrors placed in the pupil and field planes, respectively. The Shack-Hartmann measured quasi-static aberrations are used to focus the auxiliary telescopes and allow the possibility of correcting the non-common path errors between the adaptive optics systems of the unit telescopes and GRAVITY. The guiding stabilizes the light injection into single-mode fibres, increasing sensitivity and reducing the astrometric and image reconstruction errors. The beam guiding enables us to achieve an astrometric error of less than 50 μas. Here, we report on the data reduction methods and laboratory tests of the multiple-beam acquisition and guiding camera and its performance on-sky.

  20. Neural basis of forward flight control and landing in honeybees.

    PubMed

    Ibbotson, M R; Hung, Y-S; Meffin, H; Boeddeker, N; Srinivasan, M V

    2017-11-06

    The impressive repertoire of honeybee visually guided behaviors, and their ability to learn has made them an important tool for elucidating the visual basis of behavior. Like other insects, bees perform optomotor course correction to optic flow, a response that is dependent on the spatial structure of the visual environment. However, bees can also distinguish the speed of image motion during forward flight and landing, as well as estimate flight distances (odometry), irrespective of the visual scene. The neural pathways underlying these abilities are unknown. Here we report on a cluster of descending neurons (DNIIIs) that are shown to have the directional tuning properties necessary for detecting image motion during forward flight and landing on vertical surfaces. They have stable firing rates during prolonged periods of stimulation and respond to a wide range of image speeds, making them suitable to detect image flow during flight behaviors. While their responses are not strictly speed tuned, the shape and amplitudes of their speed tuning functions are resistant to large changes in spatial frequency. These cells are prime candidates not only for the control of flight speed and landing, but also the basis of a neural 'front end' of the honeybee's visual odometer.

  1. CT thermometry for cone-beam CT guided ablation

    NASA Astrophysics Data System (ADS)

    DeStefano, Zachary; Abi-Jaoudeh, Nadine; Li, Ming; Wood, Bradford J.; Summers, Ronald M.; Yao, Jianhua

    2016-03-01

    Monitoring temperature during a cone-beam CT (CBCT) guided ablation procedure is important for prevention of over-treatment and under-treatment. In order to accomplish ideal temperature monitoring, a thermometry map must be generated. Previously, this was attempted using CBCT scans of a pig shoulder undergoing ablation.1 We are extending this work by using CBCT scans of real patients and incorporating more processing steps. We register the scans before comparing them due to the movement and deformation of organs. We then automatically locate the needle tip and the ablation zone. We employ a robust change metric due to image noise and artifacts. This change metric takes windows around each pixel and uses an equation inspired by Time Delay Analysis to calculate the error between windows with the assumption that there is an ideal spatial offset. Once the change map is generated, we correlate change data with measured temperature data at the key points in the region. This allows us to transform our change map into a thermal map. This thermal map is then able to provide an estimate as to the size and temperature of the ablation zone. We evaluated our procedure on a data set of 12 patients who had a total of 24 ablation procedures performed. We were able to generate reasonable thermal maps with varying degrees of accuracy. The average error ranged from 2.7 to 16.2 degrees Celsius. In addition to providing estimates of the size of the ablation zone for surgical guidance, 3D visualizations of the ablation zone and needle are also produced.

  2. Image-guided percutaneous removal of ballistic foreign bodies secondary to air gun injuries.

    PubMed

    Rothermund, Jacob L; Rabe, Andrew J; Zumberge, Nicholas A; Murakami, James W; Warren, Patrick S; Hogan, Mark J

    2018-01-01

    Ballistic injuries with retained foreign bodies from air guns is a relatively common problem, particularly in children and adolescents. If not removed in a timely fashion, the foreign bodies can result in complications, including pain and infection. Diagnostic methods to identify the presence of the foreign body run the entire gamut of radiology, particularly radiography, ultrasound (US) and computed tomography (CT). Removal of the foreign bodies can be performed by primary care, emergency, surgical, and radiologic clinicians, with or without imaging guidance. To evaluate the modalities of radiologic detection and the experience of image-guided ballistic foreign body removal related to air gun injuries within the interventional radiology department of a large pediatric hospital. A database of more than 1,000 foreign bodies that were removed with imaging guidance by the interventional radiologists at our institution was searched for ballistic foreign bodies from air guns. The location, dimensions, diagnostic modality, duration, complications and imaging modality used for removal were recorded. In addition, the use of sedation and anesthesia required for the procedures was also recorded. Sixty-one patients with ballistic foreign bodies were identified. All foreign bodies were metallic BBs or pellets. The age of the patients ranged from 5 to 20 years. The initial diagnostic modality to detect the foreign bodies was primarily radiography. The primary modality to assist in removal was US, closely followed by fluoroscopy. For the procedure, 32.7% of the patients required some level of sedation. Only two patients had an active infection at the time of the removal. The foreign bodies were primarily in the soft tissues; however, successful removal was also performed from intraosseous, intraglandular and intratendinous locations. All cases resulted in successful removal without complications. Image-guided removal of ballistic foreign bodies secondary to air guns is a very effective procedure that can obviate the need for open surgical procedures in children.

  3. Bio-inspired approach to multistage image processing

    NASA Astrophysics Data System (ADS)

    Timchenko, Leonid I.; Pavlov, Sergii V.; Kokryatskaya, Natalia I.; Poplavska, Anna A.; Kobylyanska, Iryna M.; Burdenyuk, Iryna I.; Wójcik, Waldemar; Uvaysova, Svetlana; Orazbekov, Zhassulan; Kashaganova, Gulzhan

    2017-08-01

    Multistage integration of visual information in the brain allows people to respond quickly to most significant stimuli while preserving the ability to recognize small details in the image. Implementation of this principle in technical systems can lead to more efficient processing procedures. The multistage approach to image processing, described in this paper, comprises main types of cortical multistage convergence. One of these types occurs within each visual pathway and the other between the pathways. This approach maps input images into a flexible hierarchy which reflects the complexity of the image data. The procedures of temporal image decomposition and hierarchy formation are described in mathematical terms. The multistage system highlights spatial regularities, which are passed through a number of transformational levels to generate a coded representation of the image which encapsulates, in a computer manner, structure on different hierarchical levels in the image. At each processing stage a single output result is computed to allow a very quick response from the system. The result is represented as an activity pattern, which can be compared with previously computed patterns on the basis of the closest match.

  4. NOTE: Development and preliminary evaluation of a prototype audiovisual biofeedback device incorporating a patient-specific guiding waveform

    NASA Astrophysics Data System (ADS)

    Venkat, Raghu B.; Sawant, Amit; Suh, Yelin; George, Rohini; Keall, Paul J.

    2008-06-01

    The aim of this research was to investigate the effectiveness of a novel audio-visual biofeedback respiratory training tool to reduce respiratory irregularity. The audiovisual biofeedback system acquires sample respiratory waveforms of a particular patient and computes a patient-specific waveform to guide the patient's subsequent breathing. Two visual feedback models with different displays and cognitive loads were investigated: a bar model and a wave model. The audio instructions were ascending/descending musical tones played at inhale and exhale respectively to assist in maintaining the breathing period. Free-breathing, bar model and wave model training was performed on ten volunteers for 5 min for three repeat sessions. A total of 90 respiratory waveforms were acquired. It was found that the bar model was superior to free breathing with overall rms displacement variations of 0.10 and 0.16 cm, respectively, and rms period variations of 0.77 and 0.33 s, respectively. The wave model was superior to the bar model and free breathing for all volunteers, with an overall rms displacement of 0.08 cm and rms periods of 0.2 s. The reduction in the displacement and period variations for the bar model compared with free breathing was statistically significant (p = 0.005 and 0.002, respectively); the wave model was significantly better than the bar model (p = 0.006 and 0.005, respectively). Audiovisual biofeedback with a patient-specific guiding waveform significantly reduces variations in breathing. The wave model approach reduces cycle-to-cycle variations in displacement by greater than 50% and variations in period by over 70% compared with free breathing. The planned application of this device is anatomic and functional imaging procedures and radiation therapy delivery.

  5. Percutaneous CT-Guided Biopsies of the Cervical Spine: Technique, Histopathologic and Microbiologic Yield, and Safety at a Single Academic Institution.

    PubMed

    Wiesner, E L; Hillen, T J; Long, J; Jennings, J W

    2018-05-01

    Cervical spine biopsies can be challenging due to the anatomy and the adjacent critical structures. Percutaneous image-guided biopsies can obviate the need for an open biopsy, however there have been few studies looking at the approaches, safety, and efficacy of percutaneous cervical spine biopsies. This retrospective study evaluated technical considerations, histopathologic and microbiologic yield, and safety in CT-guided cervical bone biopsies. A retrospective review of cervical bone and/or bone/disc biopsies performed from January 2010 to January 2017 was included in this study. Clinical diagnosis and indication, patient demographics, biopsy location, biopsy needle type, technical approach, lesion size, dose-length product, conscious sedation details, complications, and diagnostic histopathologic and/or microbiologic yield were recorded for each case and summarized. A total of 73 patients underwent CT-guided cervical bone biopsies. Fifty-three percent (39/73) were for clinical/imaging concern for infection and 47% (34/73) were for primary tumors or metastatic disease. Thirty-four percent (25/73) were of the inferior cervical spine (ie, C6 and C7). A sufficient sample was obtained for histopathologic and microbiologic analyses in 96% (70/73) of the biopsies. Forty-six percent (18/39) of those samples taken for infection had positive cultures. Two intraprocedural complications occurred in which the patients became hypotensive during the procedure without long-term complications. Percutaneous CT-guided biopsy of the cervical spine is an effective and safe procedure with high diagnostic yield and can obviate open procedures for histopathologic and microbiologic analyses of patients with clinical and imaging findings concerning for infection or primary and metastatic osseous lesions. © 2018 by American Journal of Neuroradiology.

  6. A framework for breast cancer visualization using augmented reality x-ray vision technique in mobile technology

    NASA Astrophysics Data System (ADS)

    Rahman, Hameedur; Arshad, Haslina; Mahmud, Rozi; Mahayuddin, Zainal Rasyid

    2017-10-01

    Breast Cancer patients who require breast biopsy has increased over the past years. Augmented Reality guided core biopsy of breast has become the method of choice for researchers. However, this cancer visualization has limitations to the extent of superimposing the 3D imaging data only. In this paper, we are introducing an Augmented Reality visualization framework that enables breast cancer biopsy image guidance by using X-Ray vision technique on a mobile display. This framework consists of 4 phases where it initially acquires the image from CT/MRI and process the medical images into 3D slices, secondly it will purify these 3D grayscale slices into 3D breast tumor model using 3D modeling reconstruction technique. Further, in visualization processing this virtual 3D breast tumor model has been enhanced using X-ray vision technique to see through the skin of the phantom and the final composition of it is displayed on handheld device to optimize the accuracy of the visualization in six degree of freedom. The framework is perceived as an improved visualization experience because the Augmented Reality x-ray vision allowed direct understanding of the breast tumor beyond the visible surface and direct guidance towards accurate biopsy targets.

  7. New endoscopic and cytologic tools for cancer surveillance in the digestive tract

    PubMed Central

    Brentnall, Teresa A.; Dominitz, Jason A.

    2009-01-01

    Synopsis Cancer surveillance is an increasing part of everyday practice in gastrointestinal endoscopy due to the identification of high risk groups from genetic and biomarker testing, genealogic and epidemiologic studies, and the increasing number of cancer survivors. An efficient surveillance program requires a cost-effective means for image-guided cancer detection and biopsy. A laser-based tethered-capsule endoscope with enhanced spectral imaging is introduced for unsedated surveillance of the lower esophagus. An ultrathin version of this same endoscope technology provides a 1.2-mm guidewire with imaging capability and cannula-style tools are proposed for image-guided biopsy. Advanced 3D cell visualization techniques are described for increasing the sensitivity of early cancer diagnosis from hematoxylin-stained cells sampled from the pancreatic and biliary ducts. PMID:19423026

  8. Computer-based route-definition system for peripheral bronchoscopy.

    PubMed

    Graham, Michael W; Gibbs, Jason D; Higgins, William E

    2012-04-01

    Multi-detector computed tomography (MDCT) scanners produce high-resolution images of the chest. Given a patient's MDCT scan, a physician can use an image-guided intervention system to first plan and later perform bronchoscopy to diagnostic sites situated deep in the lung periphery. An accurate definition of complete routes through the airway tree leading to the diagnostic sites, however, is vital for avoiding navigation errors during image-guided bronchoscopy. We present a system for the robust definition of complete airway routes suitable for image-guided bronchoscopy. The system incorporates both automatic and semiautomatic MDCT analysis methods for this purpose. Using an intuitive graphical user interface, the user invokes automatic analysis on a patient's MDCT scan to produce a series of preliminary routes. Next, the user visually inspects each route and quickly corrects the observed route defects using the built-in semiautomatic methods. Application of the system to a human study for the planning and guidance of peripheral bronchoscopy demonstrates the efficacy of the system.

  9. Fluorescence-Guided Probes of Aptamer-Targeted Gold Nanoparticles with Computed Tomography Imaging Accesses for in Vivo Tumor Resection.

    PubMed

    Li, Cheng-Hung; Kuo, Tsung-Rong; Su, Hsin-Jan; Lai, Wei-Yun; Yang, Pan-Chyr; Chen, Jinn-Shiun; Wang, Di-Yan; Wu, Yi-Chun; Chen, Chia-Chun

    2015-10-28

    Recent development of molecular imaging probes for fluorescence-guided surgery has shown great progresses for determining tumor margin to execute the tissue resection. Here we synthesize the fluorescent gold nanoparticles conjugated with diatrizoic acid and nucleolin-targeted AS1411 aptamer. The nanoparticle conjugates exhibit high water-solubility, good biocompatibility, visible fluorescence and strong X-ray attenuation for computed tomography (CT) contrast enhancement. The fluorescent nanoparticle conjugates are applied as a molecular contrast agent to reveal the tumor location in CL1-5 tumor-bearing mice by CT imaging. Furthermore, the orange-red fluorescence emitting from the conjugates in the CL1-5 tumor can be easily visualized by the naked eyes. After the resection, the IVIS measurements show that the fluorescence signal of the nanoparticle conjugates in the tumor is greatly enhanced in comparison to that in the controlled experiment. Our work has shown potential application of functionalized nanoparticles as a dual-function imaging agent in clinical fluorescence-guided surgery.

  10. Fluorescence-Guided Probes of Aptamer-Targeted Gold Nanoparticles with Computed Tomography Imaging Accesses for in Vivo Tumor Resection

    PubMed Central

    Li, Cheng-Hung; Kuo, Tsung-Rong; Su, Hsin-Jan; Lai, Wei-Yun; Yang, Pan-Chyr; Chen, Jinn-Shiun; Wang, Di-Yan; Wu, Yi-Chun; Chen, Chia-Chun

    2015-01-01

    Recent development of molecular imaging probes for fluorescence-guided surgery has shown great progresses for determining tumor margin to execute the tissue resection. Here we synthesize the fluorescent gold nanoparticles conjugated with diatrizoic acid and nucleolin-targeted AS1411 aptamer. The nanoparticle conjugates exhibit high water-solubility, good biocompatibility, visible fluorescence and strong X-ray attenuation for computed tomography (CT) contrast enhancement. The fluorescent nanoparticle conjugates are applied as a molecular contrast agent to reveal the tumor location in CL1-5 tumor-bearing mice by CT imaging. Furthermore, the orange-red fluorescence emitting from the conjugates in the CL1-5 tumor can be easily visualized by the naked eyes. After the resection, the IVIS measurements show that the fluorescence signal of the nanoparticle conjugates in the tumor is greatly enhanced in comparison to that in the controlled experiment. Our work has shown potential application of functionalized nanoparticles as a dual-function imaging agent in clinical fluorescence-guided surgery. PMID:26507179

  11. In-Plane Ultrasound-Guided Knee Injection Through a Lateral Suprapatellar Approach: A Safe Technique.

    PubMed

    Chagas-Neto, Francisco A; Taneja, Atul K; Gregio-Junior, Everaldo; Nogueira-Barbosa, Marcello H

    2017-06-01

    This study aims to describe a technique for in-plane ultrasound-guided knee arthrography through a lateral suprapatellar approach, reporting its accuracy and related complications. A retrospective search was performed for computed tomography and magnetic resonance reports from June 2013 through June 2015. Imaging studies, puncture descriptions, and guided-procedure images were reviewed along with clinical and surgical history. A fellowship-trained musculoskeletal radiologist performed all procedures under sterile technique and ultrasound guidance with the probe in oblique position on the lateral suprapatellar recess after local anesthesia with the patient on dorsal decubitus, hip in neutral rotation, and 30 to 45 degrees of knee flexion. A total of 86 consecutive subjects were evaluated (mean, 55 years). All subjects underwent intra-articular injection of contrast, which was successfully reached in the first attempt in 94.2% of the procedures (81/86), and in the second attempt in 5.8% (5/86) after needle repositioning without a second puncture. There were no postprocedural reports of regional complications at the puncture site, such as significant pain, bleeding, or vascular lesions. Our study demonstrates that in-plane ultrasound-guided injection of the knee in semiflexion approaching the lateral suprapatellar recess is a safe and useful technique to administer intra-articular contrast solution, as an alternative method without radiation exposure.

  12. Image navigation as a means to expand the boundaries of fluorescence-guided surgery

    NASA Astrophysics Data System (ADS)

    Brouwer, Oscar R.; Buckle, Tessa; Bunschoten, Anton; Kuil, Joeri; Vahrmeijer, Alexander L.; Wendler, Thomas; Valdés-Olmos, Renato A.; van der Poel, Henk G.; van Leeuwen, Fijs W. B.

    2012-05-01

    Hybrid tracers that are both radioactive and fluorescent help extend the use of fluorescence-guided surgery to deeper structures. Such hybrid tracers facilitate preoperative surgical planning using (3D) scintigraphic images and enable synchronous intraoperative radio- and fluorescence guidance. Nevertheless, we previously found that improved orientation during laparoscopic surgery remains desirable. Here we illustrate how intraoperative navigation based on optical tracking of a fluorescence endoscope may help further improve the accuracy of hybrid surgical guidance. After feeding SPECT/CT images with an optical fiducial as a reference target to the navigation system, optical tracking could be used to position the tip of the fluorescence endoscope relative to the preoperative 3D imaging data. This hybrid navigation approach allowed us to accurately identify marker seeds in a phantom setup. The multispectral nature of the fluorescence endoscope enabled stepwise visualization of the two clinically approved fluorescent dyes, fluorescein and indocyanine green. In addition, the approach was used to navigate toward the prostate in a patient undergoing robot-assisted prostatectomy. Navigation of the tracked fluorescence endoscope toward the target identified on SPECT/CT resulted in real-time gradual visualization of the fluorescent signal in the prostate, thus providing an intraoperative confirmation of the navigation accuracy.

  13. WE-EF-BRD-03: I Want It Now!: Advances in MRI Acquisition, Reconstruction and the Use of Priors to Enable Fast Anatomic and Physiologic Imaging to Inform Guidance and Adaptation Decisions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, Y.

    MRI-guided treatment is a growing area of medicine, particularly in radiotherapy and surgery. The exquisite soft tissue anatomic contrast offered by MRI, along with functional imaging, makes the use of MRI during therapeutic procedures very attractive. Challenging the utility of MRI in the therapy room are many issues including the physics of MRI and the impact on the environment and therapeutic instruments, the impact of the room and instruments on the MRI; safety, space, design and cost. In this session, the applications and challenges of MRI-guided treatment will be described. The session format is: Past, present and future: MRI-guided radiotherapymore » from 2005 to 2025: Jan Lagendijk Battling Maxwell’s equations: Physics challenges and solutions for hybrid MRI systems: Paul Keall I want it now!: Advances in MRI acquisition, reconstruction and the use of priors to enable fast anatomic and physiologic imaging to inform guidance and adaptation decisions: Yanle Hu MR in the OR: The growth and applications of MRI for interventional radiology and surgery: Rebecca Fahrig Learning Objectives: To understand the history and trajectory of MRI-guided radiotherapy To understand the challenges of integrating MR imaging systems with linear accelerators To understand the latest in fast MRI methods to enable the visualisation of anatomy and physiology on radiotherapy treatment timescales To understand the growing role and challenges of MRI for image-guided surgical procedures My disclosures are publicly available and updated at: http://sydney.edu.au/medicine/radiation-physics/about-us/disclosures.php.« less

  14. Retinex based low-light image enhancement using guided filtering and variational framework

    NASA Astrophysics Data System (ADS)

    Zhang, Shi; Tang, Gui-jin; Liu, Xiao-hua; Luo, Su-huai; Wang, Da-dong

    2018-03-01

    A new image enhancement algorithm based on Retinex theory is proposed to solve the problem of bad visual effect of an image in low-light conditions. First, an image is converted from the RGB color space to the HSV color space to get the V channel. Next, the illuminations are respectively estimated by the guided filtering and the variational framework on the V channel and combined into a new illumination by average gradient. The new reflectance is calculated using V channel and the new illumination. Then a new V channel obtained by multiplying the new illumination and reflectance is processed with contrast limited adaptive histogram equalization (CLAHE). Finally, the new image in HSV space is converted back to RGB space to obtain the enhanced image. Experimental results show that the proposed method has better subjective quality and objective quality than existing methods.

  15. Target coverage in image-guided stereotactic body radiotherapy of liver tumors.

    PubMed

    Wunderink, Wouter; Méndez Romero, Alejandra; Vásquez Osorio, Eliana M; de Boer, Hans C J; Brandwijk, René P; Levendag, Peter C; Heijmen, Ben J M

    2007-05-01

    To determine the effect of image-guided procedures (with computed tomography [CT] and electronic portal images before each treatment fraction) on target coverage in stereotactic body radiotherapy for liver patients using a stereotactic body frame (SBF) and abdominal compression. CT guidance was used to correct for day-to-day variations in the tumor's mean position in the SBF. By retrospectively evaluating 57 treatment sessions, tumor coverage, as obtained with the clinically applied CT-guided protocol, was compared with that of alternative procedures. The internal target volume-plus (ITV(+)) was introduced to explicitly include uncertainties in tumor delineations resulting from CT-imaging artifacts caused by residual respiratory motion. Tumor coverage was defined as the volume overlap of the ITV(+), derived from a tumor delineated in a treatment CT scan, and the planning target volume. Patient stability in the SBF, after acquisition of the treatment CT scan, was evaluated by measuring the displacement of the bony anatomy in the electronic portal images relative to CT. Application of our clinical protocol (with setup corrections following from manual measurements of the distances between the contours of the planning target volume and the daily clinical target volume in three orthogonal planes, multiple two-dimensional) increased the frequency of nearly full (> or = 99%) ITV(+) coverage to 77% compared with 63% without setup correction. An automated three-dimensional method further improved the frequency to 96%. Patient displacements in the SBF were generally small (< or = 2 mm, 1 standard deviation), but large craniocaudal displacements (maximal 7.2 mm) were occasionally observed. Daily, CT-assisted patient setup may substantially improve tumor coverage, especially with the automated three-dimensional procedure. In the present treatment design, patient stability in the SBF should be verified with portal imaging.

  16. Working memory and decision processes in visual area v4.

    PubMed

    Hayden, Benjamin Y; Gallant, Jack L

    2013-01-01

    Recognizing and responding to a remembered stimulus requires the coordination of perception, working memory, and decision-making. To investigate the role of visual cortex in these processes, we recorded responses of single V4 neurons during performance of a delayed match-to-sample task that incorporates rapid serial visual presentation of natural images. We found that neuronal activity during the delay period after the cue but before the images depends on the identity of the remembered image and that this change persists while distractors appear. This persistent response modulation has been identified as a diagnostic criterion for putative working memory signals; our data thus suggest that working memory may involve reactivation of sensory neurons. When the remembered image reappears in the neuron's receptive field, visually evoked responses are enhanced; this match enhancement is a diagnostic criterion for decision. One model that predicts these data is the matched filter hypothesis, which holds that during search V4 neurons change their tuning so as to match the remembered cue, and thus become detectors for that image. More generally, these results suggest that V4 neurons participate in the perceptual, working memory, and decision processes that are needed to perform memory-guided decision-making.

  17. Eye movements, visual search and scene memory, in an immersive virtual environment.

    PubMed

    Kit, Dmitry; Katz, Leor; Sullivan, Brian; Snyder, Kat; Ballard, Dana; Hayhoe, Mary

    2014-01-01

    Visual memory has been demonstrated to play a role in both visual search and attentional prioritization in natural scenes. However, it has been studied predominantly in experimental paradigms using multiple two-dimensional images. Natural experience, however, entails prolonged immersion in a limited number of three-dimensional environments. The goal of the present experiment was to recreate circumstances comparable to natural visual experience in order to evaluate the role of scene memory in guiding eye movements in a natural environment. Subjects performed a continuous visual-search task within an immersive virtual-reality environment over three days. We found that, similar to two-dimensional contexts, viewers rapidly learn the location of objects in the environment over time, and use spatial memory to guide search. Incidental fixations did not provide obvious benefit to subsequent search, suggesting that semantic contextual cues may often be just as efficient, or that many incidentally fixated items are not held in memory in the absence of a specific task. On the third day of the experience in the environment, previous search items changed in color. These items were fixated upon with increased probability relative to control objects, suggesting that memory-guided prioritization (or Surprise) may be a robust mechanisms for attracting gaze to novel features of natural environments, in addition to task factors and simple spatial saliency.

  18. Exploratory procedures of tactile images in visually impaired and blindfolded sighted children: how they relate to their consequent performance in drawing.

    PubMed

    Vinter, Annie; Fernandes, Viviane; Orlandi, Oriana; Morgan, Pascal

    2012-01-01

    The aim of the present study was to compare the types of exploratory procedures employed by children when exploring bidimensional tactile patterns and correlate the use of these procedures with the children's shape drawing performance. 18 early blind children, 20 children with low vision and 24 age-matched blindfolded sighted children aged approximately 7 or 11 years were included in the study. The children with a visual handicap outperformed the sighted children in terms of haptic exploration and did not produce less recognizable drawings than their sighted counterparts. Close relationships were identified between the types of exploratory procedures employed by the children and their subsequent drawing performance, regardless of visual status. This close link between action and perception in the haptic modality indicates the importance of training blind children in exploratory procedures at an early age. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Real-time visualization and quantification of retrograde cardioplegia delivery using near infrared fluorescent imaging.

    PubMed

    Rangaraj, Aravind T; Ghanta, Ravi K; Umakanthan, Ramanan; Soltesz, Edward G; Laurence, Rita G; Fox, John; Cohn, Lawrence H; Bolman, R M; Frangioni, John V; Chen, Frederick Y

    2008-01-01

    Homogeneous delivery of cardioplegia is essential for myocardial protection during cardiac surgery. Presently, there exist no established methods to quantitatively assess cardioplegia distribution intraoperatively and determine when retrograde cardioplegia is required. In this study, we evaluate the feasibility of near infrared (NIR) imaging for real-time visualization of cardioplegia distribution in a porcine model. A portable, intraoperative, real-time NIR imaging system was utilized. NIR fluorescent cardioplegia solution was developed by incorporating indocyanine green (ICG) into crystalloid cardioplegia solution. Real-time NIR imaging was performed while the fluorescent cardioplegia solution was infused via the retrograde route in five ex vivo normal porcine hearts and in five ex vivo porcine hearts status post left anterior descending (LAD) coronary artery ligation. Horizontal cross-sections of the hearts were obtained at proximal, middle, and distal LAD levels. Videodensitometry was performed to quantify distribution of fluorophore content. The progressive distribution of cardioplegia was clearly visualized with NIR imaging. Complete visualization of retrograde distribution occurred within 4 minutes of infusion. Videodensitometry revealed retrograde cardioplegia, primarily distributed to the left ventricle (LV) and anterior septum. In hearts with LAD ligation, antegrade cardioplegia did not distribute to the anterior LV. This deficiency was compensated for with retrograde cardioplegia supplementation. Incorporation of ICG into cardioplegia allows real-time visualization of cardioplegia delivery via NIR imaging. This technology may prove useful in guiding intraoperative decisions pertaining to when retrograde cardioplegia is mandated.

  20. Evaluation of left ventricular scar identification from contrast enhanced magnetic resonance imaging for guidance of ventricular catheter ablation therapy

    NASA Astrophysics Data System (ADS)

    Rettmann, M. E.; Lehmann, H. I.; Johnson, S. B.; Packer, D. L.

    2016-03-01

    Patients with ventricular arrhythmias typically exhibit myocardial scarring, which is believed to be an important anatomic substrate for reentrant circuits, thereby making these regions a key target in catheter ablation therapy. In ablation therapy, a catheter is guided into the left ventricle and radiofrequency energy is delivered into the tissue to interrupt arrhythmic electrical pathways. Low bipolar voltage regions are typically localized during the procedure through point-by-point construction of an electroanatomic map by sampling the endocardial surface with the ablation catheter and are used as a surrogate for myocardial scar. This process is time consuming, requires significant skill, and has the potential to miss low voltage sites. This has led to efforts to quantify myocardial scar preoperatively using delayed, contrast-enhanced MRI. In this paper, we evaluate the utility of left ventricular scar identification from delayed contrast enhanced magnetic resonance imaging for guidance of catheter ablation of ventricular arrhythmias. Myocardial infarcts were created in three canines followed by a delayed, contrast enhanced MRI scan and electroanatomic mapping. The left ventricle and myocardial scar is segmented from preoperative MRI images and sampled points from the procedural electroanatomical map are registered to the segmented endocardial surface. Sampled points with low bipolar voltage points visually align with the segmented scar regions. This work demonstrates the potential utility of using preoperative delayed, enhanced MRI to identify myocardial scarring for guidance of ventricular catheter ablation therapy.

  1. Preoperative Navigated Transcranial Magnetic Stimulation and Tractography to Guide Endoscopic Cystoventriculostomy: A Technical Note and Case Report.

    PubMed

    Hendrix, Philipp; Senger, Sebastian; Griessenauer, Christoph J; Simgen, Andreas; Linsler, Stefan; Oertel, Joachim

    2018-01-01

    To report a technique for endoscopic cystoventriculostomy guided by preoperative navigated transcranial magnetic stimulation (nTMS) and tractography in a patient with a large speech eloquent arachnoid cyst. A 74-year old woman presented with a seizure and subsequent persistent anomic aphasia from a progressive left-sided parietal arachnoid cyst. An endoscopic cystoventriculostomy and endoscope-assisted ventricle catheter placement were performed. Surgery was guided by preoperative nTMS and tractography to avoid eloquent language, motor, and visual pathways. Preoperative nTMS motor and language mapping were used to guide tractography of motor and language white matter tracts. The ideal locations of entry point and cystoventriculostomy as well as trajectory for stent-placement were determined preoperatively with a pseudo-3-dimensional model visualizing eloquent language, motor, and visual cortical and subcortical information. The early postoperative course was uneventful. At her 3-month follow-up visit, her language impairments had completely recovered. Additionally, magnetic resonance imaging demonstrated complete collapse of the arachnoid cyst. The combination of nTMS and tractography supports the identification of a safe trajectory for cystoventriculostomy in eloquent arachnoid cysts. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Comprehensive model for predicting perceptual image quality of smart mobile devices.

    PubMed

    Gong, Rui; Xu, Haisong; Luo, M R; Li, Haifeng

    2015-01-01

    An image quality model for smart mobile devices was proposed based on visual assessments of several image quality attributes. A series of psychophysical experiments were carried out on two kinds of smart mobile devices, i.e., smart phones and tablet computers, in which naturalness, colorfulness, brightness, contrast, sharpness, clearness, and overall image quality were visually evaluated under three lighting environments via categorical judgment method for various application types of test images. On the basis of Pearson correlation coefficients and factor analysis, the overall image quality could first be predicted by its two constituent attributes with multiple linear regression functions for different types of images, respectively, and then the mathematical expressions were built to link the constituent image quality attributes with the physical parameters of smart mobile devices and image appearance factors. The procedure and algorithms were applicable to various smart mobile devices, different lighting conditions, and multiple types of images, and performance was verified by the visual data.

  3. Towards Guided Underwater Survey Using Light Visual Odometry

    NASA Astrophysics Data System (ADS)

    Nawaf, M. M.; Drap, P.; Royer, J. P.; Merad, D.; Saccone, M.

    2017-02-01

    A light distributed visual odometry method adapted to embedded hardware platform is proposed. The aim is to guide underwater surveys in real time. We rely on image stream captured using portable stereo rig attached to the embedded system. Taken images are analyzed on the fly to assess image quality in terms of sharpness and lightness, so that immediate actions can be taken accordingly. Images are then transferred over the network to another processing unit to compute the odometry. Relying on a standard ego-motion estimation approach, we speed up points matching between image quadruplets using a low level points matching scheme relying on fast Harris operator and template matching that is invariant to illumination changes. We benefit from having the light source attached to the hardware platform to estimate a priori rough depth belief following light divergence over distance low. The rough depth is used to limit points correspondence search zone as it linearly depends on disparity. A stochastic relative bundle adjustment is applied to minimize re-projection errors. The evaluation of the proposed method demonstrates the gain in terms of computation time w.r.t. other approaches that use more sophisticated feature descriptors. The built system opens promising areas for further development and integration of embedded computer vision techniques.

  4. Ultrasound imaging in medical student education: Impact on learning anatomy and physical diagnosis.

    PubMed

    So, Sokpoleak; Patel, Rita M; Orebaugh, Steven L

    2017-03-01

    Ultrasound use has expanded dramatically among the medical specialties for diagnostic and interventional purposes, due to its affordability, portability, and practicality. This imaging modality, which permits real-time visualization of anatomic structures and relationships in vivo, holds potential for pre-clinical instruction of students in anatomy and physical diagnosis, as well as providing a bridge to the eventual use of bedside ultrasound by clinicians to assess patients and guide invasive procedures. In many studies, but not all, improved understanding of anatomy has been demonstrated, and in others, improved accuracy in selected aspects of physical diagnosis is evident. Most students have expressed a highly favorable impression of this technology for anatomy education when surveyed. Logistic issues or obstacles to the integration of ultrasound imaging into anatomy teaching appear to be readily overcome. The enthusiasm of students and anatomists for teaching with ultrasound has led to widespread implementation of ultrasound-based teaching initiatives in medical schools the world over, including some with integration throughout the entire curriculum; a trend that likely will continue to grow. Anat Sci Educ 10: 176-189. © 2016 American Association of Anatomists. © 2016 American Association of Anatomists.

  5. A semi-automated image analysis procedure for in situ plankton imaging systems.

    PubMed

    Bi, Hongsheng; Guo, Zhenhua; Benfield, Mark C; Fan, Chunlei; Ford, Michael; Shahrestani, Suzan; Sieracki, Jeffery M

    2015-01-01

    Plankton imaging systems are capable of providing fine-scale observations that enhance our understanding of key physical and biological processes. However, processing the large volumes of data collected by imaging systems remains a major obstacle for their employment, and existing approaches are designed either for images acquired under laboratory controlled conditions or within clear waters. In the present study, we developed a semi-automated approach to analyze plankton taxa from images acquired by the ZOOplankton VISualization (ZOOVIS) system within turbid estuarine waters, in Chesapeake Bay. When compared to images under laboratory controlled conditions or clear waters, images from highly turbid waters are often of relatively low quality and more variable, due to the large amount of objects and nonlinear illumination within each image. We first customized a segmentation procedure to locate objects within each image and extracted them for classification. A maximally stable extremal regions algorithm was applied to segment large gelatinous zooplankton and an adaptive threshold approach was developed to segment small organisms, such as copepods. Unlike the existing approaches for images acquired from laboratory, controlled conditions or clear waters, the target objects are often the majority class, and the classification can be treated as a multi-class classification problem. We customized a two-level hierarchical classification procedure using support vector machines to classify the target objects (< 5%), and remove the non-target objects (> 95%). First, histograms of oriented gradients feature descriptors were constructed for the segmented objects. In the first step all non-target and target objects were classified into different groups: arrow-like, copepod-like, and gelatinous zooplankton. Each object was passed to a group-specific classifier to remove most non-target objects. After the object was classified, an expert or non-expert then manually removed the non-target objects that could not be removed by the procedure. The procedure was tested on 89,419 images collected in Chesapeake Bay, and results were consistent with visual counts with >80% accuracy for all three groups.

  6. A Semi-Automated Image Analysis Procedure for In Situ Plankton Imaging Systems

    PubMed Central

    Bi, Hongsheng; Guo, Zhenhua; Benfield, Mark C.; Fan, Chunlei; Ford, Michael; Shahrestani, Suzan; Sieracki, Jeffery M.

    2015-01-01

    Plankton imaging systems are capable of providing fine-scale observations that enhance our understanding of key physical and biological processes. However, processing the large volumes of data collected by imaging systems remains a major obstacle for their employment, and existing approaches are designed either for images acquired under laboratory controlled conditions or within clear waters. In the present study, we developed a semi-automated approach to analyze plankton taxa from images acquired by the ZOOplankton VISualization (ZOOVIS) system within turbid estuarine waters, in Chesapeake Bay. When compared to images under laboratory controlled conditions or clear waters, images from highly turbid waters are often of relatively low quality and more variable, due to the large amount of objects and nonlinear illumination within each image. We first customized a segmentation procedure to locate objects within each image and extracted them for classification. A maximally stable extremal regions algorithm was applied to segment large gelatinous zooplankton and an adaptive threshold approach was developed to segment small organisms, such as copepods. Unlike the existing approaches for images acquired from laboratory, controlled conditions or clear waters, the target objects are often the majority class, and the classification can be treated as a multi-class classification problem. We customized a two-level hierarchical classification procedure using support vector machines to classify the target objects (< 5%), and remove the non-target objects (> 95%). First, histograms of oriented gradients feature descriptors were constructed for the segmented objects. In the first step all non-target and target objects were classified into different groups: arrow-like, copepod-like, and gelatinous zooplankton. Each object was passed to a group-specific classifier to remove most non-target objects. After the object was classified, an expert or non-expert then manually removed the non-target objects that could not be removed by the procedure. The procedure was tested on 89,419 images collected in Chesapeake Bay, and results were consistent with visual counts with >80% accuracy for all three groups. PMID:26010260

  7. WE-EF-BRD-04: MR in the OR: The Growth and Applications of MRI for Interventional Radiology and Surgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fahrig, R.

    MRI-guided treatment is a growing area of medicine, particularly in radiotherapy and surgery. The exquisite soft tissue anatomic contrast offered by MRI, along with functional imaging, makes the use of MRI during therapeutic procedures very attractive. Challenging the utility of MRI in the therapy room are many issues including the physics of MRI and the impact on the environment and therapeutic instruments, the impact of the room and instruments on the MRI; safety, space, design and cost. In this session, the applications and challenges of MRI-guided treatment will be described. The session format is: Past, present and future: MRI-guided radiotherapymore » from 2005 to 2025: Jan Lagendijk Battling Maxwell’s equations: Physics challenges and solutions for hybrid MRI systems: Paul Keall I want it now!: Advances in MRI acquisition, reconstruction and the use of priors to enable fast anatomic and physiologic imaging to inform guidance and adaptation decisions: Yanle Hu MR in the OR: The growth and applications of MRI for interventional radiology and surgery: Rebecca Fahrig Learning Objectives: To understand the history and trajectory of MRI-guided radiotherapy To understand the challenges of integrating MR imaging systems with linear accelerators To understand the latest in fast MRI methods to enable the visualisation of anatomy and physiology on radiotherapy treatment timescales To understand the growing role and challenges of MRI for image-guided surgical procedures My disclosures are publicly available and updated at: http://sydney.edu.au/medicine/radiation-physics/about-us/disclosures.php.« less

  8. WE-EF-BRD-02: Battling Maxwell’s Equations: Physics Challenges and Solutions for Hybrid MRI Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keall, P.

    MRI-guided treatment is a growing area of medicine, particularly in radiotherapy and surgery. The exquisite soft tissue anatomic contrast offered by MRI, along with functional imaging, makes the use of MRI during therapeutic procedures very attractive. Challenging the utility of MRI in the therapy room are many issues including the physics of MRI and the impact on the environment and therapeutic instruments, the impact of the room and instruments on the MRI; safety, space, design and cost. In this session, the applications and challenges of MRI-guided treatment will be described. The session format is: Past, present and future: MRI-guided radiotherapymore » from 2005 to 2025: Jan Lagendijk Battling Maxwell’s equations: Physics challenges and solutions for hybrid MRI systems: Paul Keall I want it now!: Advances in MRI acquisition, reconstruction and the use of priors to enable fast anatomic and physiologic imaging to inform guidance and adaptation decisions: Yanle Hu MR in the OR: The growth and applications of MRI for interventional radiology and surgery: Rebecca Fahrig Learning Objectives: To understand the history and trajectory of MRI-guided radiotherapy To understand the challenges of integrating MR imaging systems with linear accelerators To understand the latest in fast MRI methods to enable the visualisation of anatomy and physiology on radiotherapy treatment timescales To understand the growing role and challenges of MRI for image-guided surgical procedures My disclosures are publicly available and updated at: http://sydney.edu.au/medicine/radiation-physics/about-us/disclosures.php.« less

  9. 1.5 T augmented reality navigated interventional MRI: paravertebral sympathetic plexus injections

    PubMed Central

    Marker, David R.; U-Thainual, Paweena; Ungi, Tamas; Flammang, Aaron J.; Fichtinger, Gabor; Iordachita, Iulian I.; Carrino, John A.; Fritz, Jan

    2017-01-01

    PURPOSE The high contrast resolution and absent ionizing radiation of interventional magnetic resonance imaging (MRI) can be advantageous for paravertebral sympathetic nerve plexus injections. We assessed the feasibility and technical performance of MRI-guided paravertebral sympathetic injections utilizing augmented reality navigation and 1.5 T MRI scanner. METHODS A total of 23 bilateral injections of the thoracic (8/23, 35%), lumbar (8/23, 35%), and hypogastric (7/23, 30%) paravertebral sympathetic plexus were prospectively planned in twelve human cadavers using a 1.5 Tesla (T) MRI scanner and augmented reality navigation system. MRI-conditional needles were used. Gadolinium-DTPA-enhanced saline was injected. Outcome variables included the number of control magnetic resonance images, target error of the needle tip, punctures of critical nontarget structures, distribution of the injected fluid, and procedure length. RESULTS Augmented-reality navigated MRI guidance at 1.5 T provided detailed anatomical visualization for successful targeting of the paravertebral space, needle placement, and perineural paravertebral injections in 46 of 46 targets (100%). A mean of 2 images (range, 1–5 images) were required to control needle placement. Changes of the needle trajectory occurred in 9 of 46 targets (20%) and changes of needle advancement occurred in 6 of 46 targets (13%), which were statistically not related to spinal regions (P = 0.728 and P = 0.86, respectively) and cadaver sizes (P = 0.893 and P = 0.859, respectively). The mean error of the needle tip was 3.9±1.7 mm. There were no punctures of critical nontarget structures. The mean procedure length was 33±12 min. CONCLUSION 1.5 T augmented reality-navigated interventional MRI can provide accurate imaging guidance for perineural injections of the thoracic, lumbar, and hypogastric sympathetic plexus. PMID:28420598

  10. 1.5 T augmented reality navigated interventional MRI: paravertebral sympathetic plexus injections.

    PubMed

    Marker, David R; U Thainual, Paweena; Ungi, Tamas; Flammang, Aaron J; Fichtinger, Gabor; Iordachita, Iulian I; Carrino, John A; Fritz, Jan

    2017-01-01

    The high contrast resolution and absent ionizing radiation of interventional magnetic resonance imaging (MRI) can be advantageous for paravertebral sympathetic nerve plexus injections. We assessed the feasibility and technical performance of MRI-guided paravertebral sympathetic injections utilizing augmented reality navigation and 1.5 T MRI scanner. A total of 23 bilateral injections of the thoracic (8/23, 35%), lumbar (8/23, 35%), and hypogastric (7/23, 30%) paravertebral sympathetic plexus were prospectively planned in twelve human cadavers using a 1.5 Tesla (T) MRI scanner and augmented reality navigation system. MRI-conditional needles were used. Gadolinium-DTPA-enhanced saline was injected. Outcome variables included the number of control magnetic resonance images, target error of the needle tip, punctures of critical nontarget structures, distribution of the injected fluid, and procedure length. Augmented-reality navigated MRI guidance at 1.5 T provided detailed anatomical visualization for successful targeting of the paravertebral space, needle placement, and perineural paravertebral injections in 46 of 46 targets (100%). A mean of 2 images (range, 1-5 images) were required to control needle placement. Changes of the needle trajectory occurred in 9 of 46 targets (20%) and changes of needle advancement occurred in 6 of 46 targets (13%), which were statistically not related to spinal regions (P = 0.728 and P = 0.86, respectively) and cadaver sizes (P = 0.893 and P = 0.859, respectively). The mean error of the needle tip was 3.9±1.7 mm. There were no punctures of critical nontarget structures. The mean procedure length was 33±12 min. 1.5 T augmented reality-navigated interventional MRI can provide accurate imaging guidance for perineural injections of the thoracic, lumbar, and hypogastric sympathetic plexus.

  11. CISUS: an integrated 3D ultrasound system for IGT using a modular tracking API

    NASA Astrophysics Data System (ADS)

    Boctor, Emad M.; Viswanathan, Anand; Pieper, Steve; Choti, Michael A.; Taylor, Russell H.; Kikinis, Ron; Fichtinger, Gabor

    2004-05-01

    Ultrasound has become popular in clinical/surgical applications, both as the primary image guidance modality and also in conjunction with other modalities like CT or MRI. Three dimensional ultrasound (3DUS) systems have also demonstrated usefulness in image-guided therapy (IGT). At the same time, however, current lack of open-source and open-architecture multi-modal medical visualization systems prevents 3DUS from fulfilling its potential. Several stand-alone 3DUS systems, like Stradx or In-Vivo exist today. Although these systems have been found to be useful in real clinical setting, it is difficult to augment their functionality and integrate them in versatile IGT systems. To address these limitations, a robotic/freehand 3DUS open environment (CISUS) is being integrated into the 3D Slicer, an open-source research tool developed for medical image analysis and surgical planning. In addition, the system capitalizes on generic application programming interfaces (APIs) for tracking devices and robotic control. The resulting platform-independent open-source system may serve as a valuable tool to the image guided surgery community. Other researchers could straightforwardly integrate the generic CISUS system along with other functionalities (i.e. dual view visualization, registration, real-time tracking, segmentation, etc) to rapidly create their medical/surgical applications. Our current driving clinical application is robotically assisted and freehand 3DUS-guided liver ablation, which is fully being integrated under the CISUS-3D Slicer. Initial functionality and pre-clinical feasibility are demonstrated on phantom and ex-vivo animal models.

  12. [Image guided and robotic treatment--the advance of cybernetics in clinical medicine].

    PubMed

    Fosse, E; Elle, O J; Samset, E; Johansen, M; Røtnes, J S; Tønnessen, T I; Edwin, B

    2000-01-10

    The introduction of advanced technology in hospitals has changed the treatment practice towards more image guided and minimal invasive procedures. Modern computer and communication technology opens up for robot aided and pre-programmed intervention. Several robotic systems are in clinical use today both in microsurgery and in major cardiac and orthopedic operations. As this trend develops, professions which are new in this context such as physicists, mathematicians and cybernetic engineers will be increasingly important in the treatment of patients.

  13. Topography-modified refraction (TMR): adjustment of treated cylinder amount and axis to the topography versus standard clinical refraction in myopic topography-guided LASIK.

    PubMed

    Kanellopoulos, Anastasios John

    2016-01-01

    To evaluate the safety, efficacy, and contralateral eye comparison of topography-guided myopic LASIK with two different refraction treatment strategies. Private clinical ophthalmology practice. A total of 100 eyes (50 patients) in consecutive cases of myopic topography-guided LASIK procedures with the same refractive platform (FS200 femtosecond and EX500 excimer lasers) were randomized for treatment as follows: one eye with the standard clinical refraction (group A) and the contralateral eye with the topographic astigmatic power and axis (topography-modified treatment refraction; group B). All cases were evaluated pre- and post-operatively for the following parameters: refractive error, best corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), topography (Placido-disk based) and tomography (Scheimpflug-image based), wavefront analysis, pupillometry, and contrast sensitivity. Follow-up visits were conducted for at least 12 months. Mean refractive error was -5.5 D of myopia and -1.75 D of astigmatism. In group A versus group B, respectively, the average UDVA improved from 20/200 to 20/20 versus 20/16; post-operative CDVA was 20/20 and 20/13.5; 1 line of vision gained was 27.8% and 55.6%; and 2 lines of vision gained was 5.6% and 11.1%. In group A, 27.8% of eyes had over -0.50 diopters of residual refractive astigmatism, in comparison to 11.7% in group B ( P <0.01). The residual percentages in both groups were measured with refractive astigmatism of more than -0.5 diopters. Topography-modified refraction (TMR): topographic adjustment of the amount and axis of astigmatism treated, when different from the clinical refraction, may offer superior outcomes in topography-guided myopic LASIK. These findings may change the current clinical paradigm of the optimal subjective refraction utilized in laser vision correction.

  14. Topography-modified refraction (TMR): adjustment of treated cylinder amount and axis to the topography versus standard clinical refraction in myopic topography-guided LASIK

    PubMed Central

    Kanellopoulos, Anastasios John

    2016-01-01

    Purpose To evaluate the safety, efficacy, and contralateral eye comparison of topography-guided myopic LASIK with two different refraction treatment strategies. Setting Private clinical ophthalmology practice. Patients and methods A total of 100 eyes (50 patients) in consecutive cases of myopic topography-guided LASIK procedures with the same refractive platform (FS200 femtosecond and EX500 excimer lasers) were randomized for treatment as follows: one eye with the standard clinical refraction (group A) and the contralateral eye with the topographic astigmatic power and axis (topography-modified treatment refraction; group B). All cases were evaluated pre- and post-operatively for the following parameters: refractive error, best corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), topography (Placido-disk based) and tomography (Scheimpflug-image based), wavefront analysis, pupillometry, and contrast sensitivity. Follow-up visits were conducted for at least 12 months. Results Mean refractive error was −5.5 D of myopia and −1.75 D of astigmatism. In group A versus group B, respectively, the average UDVA improved from 20/200 to 20/20 versus 20/16; post-operative CDVA was 20/20 and 20/13.5; 1 line of vision gained was 27.8% and 55.6%; and 2 lines of vision gained was 5.6% and 11.1%. In group A, 27.8% of eyes had over −0.50 diopters of residual refractive astigmatism, in comparison to 11.7% in group B (P<0.01). The residual percentages in both groups were measured with refractive astigmatism of more than −0.5 diopters. Conclusion Topography-modified refraction (TMR): topographic adjustment of the amount and axis of astigmatism treated, when different from the clinical refraction, may offer superior outcomes in topography-guided myopic LASIK. These findings may change the current clinical paradigm of the optimal subjective refraction utilized in laser vision correction. PMID:27843292

  15. Soundwalk approach to identify urban soundscapes individually.

    PubMed

    Jeon, Jin Yong; Hong, Joo Young; Lee, Pyoung Jik

    2013-07-01

    This study proposes a soundwalk procedure for evaluating urban soundscapes. Previous studies, which adopted soundwalk methodologies for investigating participants' responses to visual and acoustic environments, were analyzed considering type, evaluation position, measurement, and subjective assessment. An individual soundwalk procedure was then developed based on asking individual subjects to walk and select evaluation positions where they perceived any positive or negative characteristics of the urban soundscape. A case study was performed in urban spaces and the results were compared with those of the group soundwalk to validate the individual soundwalk procedure. Thirty subjects (15 architects and 15 acousticians) participated in the soundwalk. During the soundwalk, the subjects selected a total of 196 positions, and those were classified into 4 groups. It was found that soundscape perceptions were dominated by acoustic comfort, visual images, and openness. It was also revealed that perceived elements of the acoustic environment and visual image differed across classified soundscape groups, and there was a difference between architects and acousticians in terms of how they described their impressions of the soundscape elements. The results show that the individual soundwalk procedure has advantages for measuring diverse subjective responses and for obtaining the perceived elements of the urban soundscape.

  16. Integration for navigation on the UMASS mobile perception lab

    NASA Technical Reports Server (NTRS)

    Draper, Bruce; Fennema, Claude; Rochwerger, Benny; Riseman, Edward; Hanson, Allen

    1994-01-01

    Integration of real-time visual procedures for use on the Mobile Perception Lab (MPL) was presented. The MPL is an autonomous vehicle designed for testing visually guided behavior. Two critical areas of focus in the system design were data storage/exchange and process control. The Intermediate Symbolic Representation (ISR3) supported data storage and exchange, and the MPL script monitor provided process control. Resource allocation, inter-process communication, and real-time control are difficult problems which must be solved in order to construct strong autonomous systems.

  17. Retinal Image Simulation of Subjective Refraction Techniques

    PubMed Central

    Perches, Sara; Collados, M. Victoria; Ares, Jorge

    2016-01-01

    Refraction techniques make it possible to determine the most appropriate sphero-cylindrical lens prescription to achieve the best possible visual quality. Among these techniques, subjective refraction (i.e., patient’s response-guided refraction) is the most commonly used approach. In this context, this paper’s main goal is to present a simulation software that implements in a virtual manner various subjective-refraction techniques—including Jackson’s Cross-Cylinder test (JCC)—relying all on the observation of computer-generated retinal images. This software has also been used to evaluate visual quality when the JCC test is performed in multifocal-contact-lens wearers. The results reveal this software’s usefulness to simulate the retinal image quality that a particular visual compensation provides. Moreover, it can help to gain a deeper insight and to improve existing refraction techniques and it can be used for simulated training. PMID:26938648

  18. Augmented-reality visualization of brain structures with stereo and kinetic depth cues: system description and initial evaluation with head phantom

    NASA Astrophysics Data System (ADS)

    Maurer, Calvin R., Jr.; Sauer, Frank; Hu, Bo; Bascle, Benedicte; Geiger, Bernhard; Wenzel, Fabian; Recchi, Filippo; Rohlfing, Torsten; Brown, Christopher R.; Bakos, Robert J.; Maciunas, Robert J.; Bani-Hashemi, Ali R.

    2001-05-01

    We are developing a video see-through head-mounted display (HMD) augmented reality (AR) system for image-guided neurosurgical planning and navigation. The surgeon wears a HMD that presents him with the augmented stereo view. The HMD is custom fitted with two miniature color video cameras that capture a stereo view of the real-world scene. We are concentrating specifically at this point on cranial neurosurgery, so the images will be of the patient's head. A third video camera, operating in the near infrared, is also attached to the HMD and is used for head tracking. The pose (i.e., position and orientation) of the HMD is used to determine where to overlay anatomic structures segmented from preoperative tomographic images (e.g., CT, MR) on the intraoperative video images. Two SGI 540 Visual Workstation computers process the three video streams and render the augmented stereo views for display on the HMD. The AR system operates in real time at 30 frames/sec with a temporal latency of about three frames (100 ms) and zero relative lag between the virtual objects and the real-world scene. For an initial evaluation of the system, we created AR images using a head phantom with actual internal anatomic structures (segmented from CT and MR scans of a patient) realistically positioned inside the phantom. When using shaded renderings, many users had difficulty appreciating overlaid brain structures as being inside the head. When using wire frames, and texture-mapped dot patterns, most users correctly visualized brain anatomy as being internal and could generally appreciate spatial relationships among various objects. The 3D perception of these structures is based on both stereoscopic depth cues and kinetic depth cues, with the user looking at the head phantom from varying positions. The perception of the augmented visualization is natural and convincing. The brain structures appear rigidly anchored in the head, manifesting little or no apparent swimming or jitter. The initial evaluation of the system is encouraging, and we believe that AR visualization might become an important tool for image-guided neurosurgical planning and navigation.

  19. Global Skin-Friction Measurements Using Particle Image Surface FLow Visualization and a Luminescent Oil-Film

    NASA Technical Reports Server (NTRS)

    Husen, Nicholas; Roozeboom, Nettie; Liu, Tianshu; Sullivan, John P.

    2015-01-01

    A quantitative global skin-friction measurement technique is proposed. An oil-film is doped with a luminescent molecule and thereby made to fluoresce in order to resolve oil-film thickness, and Particle Image Surface Flow Visualization is used to resolve the velocity field of the surface of the oil-film. Skin-friction is then calculated at location x as (x )xh, where x is the displacement of the surface of the oil-film and is the dynamic viscosity of the oil. The data collection procedure and data analysis procedures are explained, and preliminary experimental skin-friction results for flow over the wing of the CRM are presented.

  20. Propagation of registration uncertainty during multi-fraction cervical cancer brachytherapy

    NASA Astrophysics Data System (ADS)

    Amir-Khalili, A.; Hamarneh, G.; Zakariaee, R.; Spadinger, I.; Abugharbieh, R.

    2017-10-01

    Multi-fraction cervical cancer brachytherapy is a form of image-guided radiotherapy that heavily relies on 3D imaging during treatment planning, delivery, and quality control. In this context, deformable image registration can increase the accuracy of dosimetric evaluations, provided that one can account for the uncertainties associated with the registration process. To enable such capability, we propose a mathematical framework that first estimates the registration uncertainty and subsequently propagates the effects of the computed uncertainties from the registration stage through to the visualizations, organ segmentations, and dosimetric evaluations. To ensure the practicality of our proposed framework in real world image-guided radiotherapy contexts, we implemented our technique via a computationally efficient and generalizable algorithm that is compatible with existing deformable image registration software. In our clinical context of fractionated cervical cancer brachytherapy, we perform a retrospective analysis on 37 patients and present evidence that our proposed methodology for computing and propagating registration uncertainties may be beneficial during therapy planning and quality control. Specifically, we quantify and visualize the influence of registration uncertainty on dosimetric analysis during the computation of the total accumulated radiation dose on the bladder wall. We further show how registration uncertainty may be leveraged into enhanced visualizations that depict the quality of the registration and highlight potential deviations from the treatment plan prior to the delivery of radiation treatment. Finally, we show that we can improve the transfer of delineated volumetric organ segmentation labels from one fraction to the next by encoding the computed registration uncertainties into the segmentation labels.

  1. Environmental Recognition and Guidance Control for Autonomous Vehicles using Dual Vision Sensor and Applications

    NASA Astrophysics Data System (ADS)

    Moriwaki, Katsumi; Koike, Issei; Sano, Tsuyoshi; Fukunaga, Tetsuya; Tanaka, Katsuyuki

    We propose a new method of environmental recognition around an autonomous vehicle using dual vision sensor and navigation control based on binocular images. We consider to develop a guide robot that can play the role of a guide dog as the aid to people such as the visually impaired or the aged, as an application of above-mentioned techniques. This paper presents a recognition algorithm, which finds out the line of a series of Braille blocks and the boundary line between a sidewalk and a roadway where a difference in level exists by binocular images obtained from a pair of parallelarrayed CCD cameras. This paper also presents a tracking algorithm, with which the guide robot traces along a series of Braille blocks and avoids obstacles and unsafe areas which exist in the way of a person with the guide robot.

  2. Multi-mode Intravascular RF Coil for MRI-guided Interventions

    PubMed Central

    Kurpad, Krishna N.; Unal, Orhan

    2011-01-01

    Purpose To demonstrate the feasibility of using a single intravascular RF probe connected to the external MRI system via a single coaxial cable to perform active tip tracking and catheter visualization, and high SNR intravascular imaging. Materials and Methods A multi-mode intravascular RF coil was constructed on a 6F balloon catheter and interfaced to a 1.5T MRI scanner via a decoupling circuit. Bench measurements of coil impedances were followed by imaging experiments in saline and phantoms. Results The multi-mode coil behaves as an inductively-coupled transmit coil. Forward looking capability of 6mm is measured. Greater than 3-fold increase in SNR compared to conventional imaging using optimized external coil is demonstrated. Simultaneous active tip tracking and catheter visualization is demonstrated. Conclusions It is feasible to perform 1) active tip tracking, 2) catheter visualization, and 3) high SNR imaging using a single multi-mode intravascular RF coil that is connected to the external system via a single coaxial cable. PMID:21448969

  3. Smartphones as multimodal communication devices to facilitate clinical knowledge processes: randomized controlled trial.

    PubMed

    Pimmer, Christoph; Mateescu, Magdalena; Zahn, Carmen; Genewein, Urs

    2013-11-27

    Despite the widespread use and advancements of mobile technology that facilitate rich communication modes, there is little evidence demonstrating the value of smartphones for effective interclinician communication and knowledge processes. The objective of this study was to determine the effects of different synchronous smartphone-based modes of communication, such as (1) speech only, (2) speech and images, and (3) speech, images, and image annotation (guided noticing) on the recall and transfer of visually and verbally represented medical knowledge. The experiment was conducted from November 2011 to May 2012 at the University Hospital Basel (Switzerland) with 42 medical students in a master's program. All participants analyzed a standardized case (a patient with a subcapital fracture of the fifth metacarpal bone) based on a radiological image, photographs of the hand, and textual descriptions, and were asked to consult a remote surgical specialist via a smartphone. Participants were randomly assigned to 3 experimental conditions/groups. In group 1, the specialist provided verbal explanations (speech only). In group 2, the specialist provided verbal explanations and displayed the radiological image and the photographs to the participants (speech and images). In group 3, the specialist provided verbal explanations, displayed the radiological image and the photographs, and annotated the radiological image by drawing structures/angle elements (speech, images, and image annotation). To assess knowledge recall, participants were asked to write brief summaries of the case (verbally represented knowledge) after the consultation and to re-analyze the diagnostic images (visually represented knowledge). To assess knowledge transfer, participants analyzed a similar case without specialist support. Data analysis by ANOVA found that participants in groups 2 and 3 (images used) evaluated the support provided by the specialist as significantly more positive than group 1, the speech-only group (group 1: mean 4.08, SD 0.90; group 2: mean 4.73, SD 0.59; group 3: mean 4.93, SD 0.25; F2,39=6.76, P=.003; partial η(2)=0.26, 1-β=.90). However, significant positive effects on the recall and transfer of visually represented medical knowledge were only observed when the smartphone-based communication involved the combination of speech, images, and image annotation (group 3). There were no significant positive effects on the recall and transfer of visually represented knowledge between group 1 (speech only) and group 2 (speech and images). No significant differences were observed between the groups regarding verbally represented medical knowledge. The results show (1) the value of annotation functions for digital and mobile technology for interclinician communication and medical informatics, and (2) the use of guided noticing (the integration of speech, images, and image annotation) leads to significantly improved knowledge gains for visually represented knowledge. This is particularly valuable in situations involving complex visual subject matters, typical in clinical practice.

  4. Smartphones as Multimodal Communication Devices to Facilitate Clinical Knowledge Processes: Randomized Controlled Trial

    PubMed Central

    Mateescu, Magdalena; Zahn, Carmen; Genewein, Urs

    2013-01-01

    Background Despite the widespread use and advancements of mobile technology that facilitate rich communication modes, there is little evidence demonstrating the value of smartphones for effective interclinician communication and knowledge processes. Objective The objective of this study was to determine the effects of different synchronous smartphone-based modes of communication, such as (1) speech only, (2) speech and images, and (3) speech, images, and image annotation (guided noticing) on the recall and transfer of visually and verbally represented medical knowledge. Methods The experiment was conducted from November 2011 to May 2012 at the University Hospital Basel (Switzerland) with 42 medical students in a master’s program. All participants analyzed a standardized case (a patient with a subcapital fracture of the fifth metacarpal bone) based on a radiological image, photographs of the hand, and textual descriptions, and were asked to consult a remote surgical specialist via a smartphone. Participants were randomly assigned to 3 experimental conditions/groups. In group 1, the specialist provided verbal explanations (speech only). In group 2, the specialist provided verbal explanations and displayed the radiological image and the photographs to the participants (speech and images). In group 3, the specialist provided verbal explanations, displayed the radiological image and the photographs, and annotated the radiological image by drawing structures/angle elements (speech, images, and image annotation). To assess knowledge recall, participants were asked to write brief summaries of the case (verbally represented knowledge) after the consultation and to re-analyze the diagnostic images (visually represented knowledge). To assess knowledge transfer, participants analyzed a similar case without specialist support. Results Data analysis by ANOVA found that participants in groups 2 and 3 (images used) evaluated the support provided by the specialist as significantly more positive than group 1, the speech-only group (group 1: mean 4.08, SD 0.90; group 2: mean 4.73, SD 0.59; group 3: mean 4.93, SD 0.25; F 2,39=6.76, P=.003; partial η2=0.26, 1–β=.90). However, significant positive effects on the recall and transfer of visually represented medical knowledge were only observed when the smartphone-based communication involved the combination of speech, images, and image annotation (group 3). There were no significant positive effects on the recall and transfer of visually represented knowledge between group 1 (speech only) and group 2 (speech and images). No significant differences were observed between the groups regarding verbally represented medical knowledge. Conclusions The results show (1) the value of annotation functions for digital and mobile technology for interclinician communication and medical informatics, and (2) the use of guided noticing (the integration of speech, images, and image annotation) leads to significantly improved knowledge gains for visually represented knowledge. This is particularly valuable in situations involving complex visual subject matters, typical in clinical practice. PMID:24284080

  5. Cost analysis of PET and comprehensive lifestyle modification for the reversal of atherosclerosis.

    PubMed

    Delgado, Rigoberto I; Swint, J Michael; Lairson, David R; Johnson, Nils P; Gould, K Lance; Sdringola, Stefano

    2014-01-01

    We present a preliminary cost analysis of a combination intervention using PET and comprehensive lifestyle modification to reverse atherosclerosis. With a sensitivity of 92%-95% and specificity of 85%-95%, PET is an essential tool for high-precision diagnosis of coronary artery disease, accurately guiding optimal treatment for both symptomatic and asymptomatic patients. PET imaging provides a powerful visual and educational aid for helping patients identify and adopt appropriate treatments. However, little is known about the operational cost of using the technology for this purpose. The analysis was done in the context of the Century Health Study for Cardiovascular Medicine (Century Trial), a 1,300-patient, randomized study combining PET imaging with lifestyle changes. Our methodology included a microcosting and time study focusing on estimating average direct and indirect costs. The total cost of the Century Trial in present-value terms is $9.2 million, which is equal to $7,058 per patient. Sensitivity analysis indicates that the present value of total costs is likely to range between $8.8 and $9.7 million, which is equivalent to $6,655-$7,606 per patient. The clinical relevance of the Century Trial is significant since it is, to our knowledge, the first randomized controlled trial to combine high-precision imaging with lifestyle strategies. The Century Trial is in its second year of a 5-y protocol, and we present preliminary findings. The results of this cost study, however, provide policy makers with an early estimate of the costs of implementing, at large scale, a combined intervention such as the Century Trial. Further, we believe that imaging-guided lifestyle management may have considerable potential for improving outcomes and reducing health-care costs by eliminating unnecessary invasive procedures.

  6. Piezoelectrically Actuated Robotic System for MRI-Guided Prostate Percutaneous Therapy

    PubMed Central

    Su, Hao; Shang, Weijian; Cole, Gregory; Li, Gang; Harrington, Kevin; Camilo, Alexander; Tokuda, Junichi; Tempany, Clare M.; Hata, Nobuhiko; Fischer, Gregory S.

    2014-01-01

    This paper presents a fully-actuated robotic system for percutaneous prostate therapy under continuously acquired live magnetic resonance imaging (MRI) guidance. The system is composed of modular hardware and software to support the surgical workflow of intra-operative MRI-guided surgical procedures. We present the development of a 6-degree-of-freedom (DOF) needle placement robot for transperineal prostate interventions. The robot consists of a 3-DOF needle driver module and a 3-DOF Cartesian motion module. The needle driver provides needle cannula translation and rotation (2-DOF) and stylet translation (1-DOF). A custom robot controller consisting of multiple piezoelectric motor drivers provides precision closed-loop control of piezoelectric motors and enables simultaneous robot motion and MR imaging. The developed modular robot control interface software performs image-based registration, kinematics calculation, and exchanges robot commands and coordinates between the navigation software and the robot controller with a new implementation of the open network communication protocol OpenIGTLink. Comprehensive compatibility of the robot is evaluated inside a 3-Tesla MRI scanner using standard imaging sequences and the signal-to-noise ratio (SNR) loss is limited to 15%. The image deterioration due to the present and motion of robot demonstrates unobservable image interference. Twenty-five targeted needle placements inside gelatin phantoms utilizing an 18-gauge ceramic needle demonstrated 0.87 mm root mean square (RMS) error in 3D Euclidean distance based on MRI volume segmentation of the image-guided robotic needle placement procedure. PMID:26412962

  7. A Practical and Portable Solids-State Electronic Terahertz Imaging System

    PubMed Central

    Smart, Ken; Du, Jia; Li, Li; Wang, David; Leslie, Keith; Ji, Fan; Li, Xiang Dong; Zeng, Da Zhang

    2016-01-01

    A practical compact solid-state terahertz imaging system is presented. Various beam guiding architectures were explored and hardware performance assessed to improve its compactness, robustness, multi-functionality and simplicity of operation. The system performance in terms of image resolution, signal-to-noise ratio, the electronic signal modulation versus optical chopper, is evaluated and discussed. The system can be conveniently switched between transmission and reflection mode according to the application. A range of imaging application scenarios was explored and images of high visual quality were obtained in both transmission and reflection mode. PMID:27110791

  8. An interventional multispectral photoacoustic imaging platform for the guidance of minimally invasive procedures

    NASA Astrophysics Data System (ADS)

    Xia, Wenfeng; Nikitichev, Daniil I.; Mari, Jean Martial; West, Simeon J.; Ourselin, Sebastien; Beard, Paul C.; Desjardins, Adrien E.

    2015-07-01

    Precise and efficient guidance of medical devices is of paramount importance for many minimally invasive procedures. These procedures include fetal interventions, tumor biopsies and treatments, central venous catheterisations and peripheral nerve blocks. Ultrasound imaging is commonly used for guidance, but it often provides insufficient contrast with which to identify soft tissue structures such as vessels, tumors, and nerves. In this study, a hybrid interventional imaging system that combines ultrasound imaging and multispectral photoacoustic imaging for guiding minimally invasive procedures was developed and characterized. The system provides both structural information from ultrasound imaging and molecular information from multispectral photoacoustic imaging. It uses a commercial linear-array ultrasound imaging probe as the ultrasound receiver, with a multimode optical fiber embedded in a needle to deliver pulsed excitation light to tissue. Co-registration of ultrasound and photoacoustic images is achieved with the use of the same ultrasound receiver for both modalities. Using tissue ex vivo, the system successfully discriminated deep-located fat tissue from the surrounding muscle tissue. The measured photoacoustic spectrum of the fat tissue had good agreement with the lipid spectrum in literature.

  9. Ultrasound-guided versus computed tomography-scan guided biopsy of pleural-based lung lesions

    PubMed Central

    Khosla, Rahul; McLean, Anna W; Smith, Jessica A

    2016-01-01

    Background: Computed tomography (CT) guided biopsies have long been the standard technique to obtain tissue from the thoracic cavity and is traditionally performed by interventional radiologists. Ultrasound (US) guided biopsy of pleural-based lesions, performed by pulmonologists is gaining popularity and has the advantage of multi-planar imaging, real-time technique, and the absence of radiation exposure to patients. In this study, we aim to determine the diagnostic accuracy, the time to diagnosis after the initial consult placement, and the complications rates between the two different modalities. Methods: A retrospective study of electronic medical records was done of patients who underwent CT-guided biopsies and US-guided biopsies for pleural-based lesions between 2005 and 2014 and the data collected were analyzed for comparing the two groups. Results: A total of 158 patients underwent 162 procedures during the study period. 86 patients underwent 89 procedures in the US group, and 72 patients underwent 73 procedures in the CT group. The overall yield in the US group was 82/89 (92.1%) versus 67/73 (91.8%) in the CT group (P = 1.0). Average days to the procedure was 7.2 versus 17.5 (P = 0.00001) in the US and CT group, respectively. Complication rate was higher in CT group 17/73 (23.3%) versus 1/89 (1.1%) in the US group (P < 0.0001). Conclusions: For pleural-based lesions the diagnostic accuracy of US guided biopsy is similar to that of CT-guided biopsy, with a lower complication rate and a significantly reduced time to the procedure. PMID:27625440

  10. Target position uncertainty during visually guided deep-inspiration breath-hold radiotherapy in locally advanced lung cancer.

    PubMed

    Scherman Rydhög, Jonas; Riisgaard de Blanck, Steen; Josipovic, Mirjana; Irming Jølck, Rasmus; Larsen, Klaus Richter; Clementsen, Paul; Lars Andersen, Thomas; Poulsen, Per Rugaard; Fredberg Persson, Gitte; Munck Af Rosenschold, Per

    2017-04-01

    The purpose of this study was to estimate the uncertainty in voluntary deep-inspiration breath-hold (DIBH) radiotherapy for locally advanced non-small cell lung cancer (NSCLC) patients. Perpendicular fluoroscopic movies were acquired in free breathing (FB) and DIBH during a course of visually guided DIBH radiotherapy of nine patients with NSCLC. Patients had liquid markers injected in mediastinal lymph nodes and primary tumours. Excursion, systematic- and random errors, and inter-breath-hold position uncertainty were investigated using an image based tracking algorithm. A mean reduction of 2-6mm in marker excursion in DIBH versus FB was seen in the anterior-posterior (AP), left-right (LR) and cranio-caudal (CC) directions. Lymph node motion during DIBH originated from cardiac motion. The systematic- (standard deviation (SD) of all the mean marker positions) and random errors (root-mean-square of the intra-BH SD) during DIBH were 0.5 and 0.3mm (AP), 0.5 and 0.3mm (LR), 0.8 and 0.4mm (CC), respectively. The mean inter-breath-hold shifts were -0.3mm (AP), -0.2mm (LR), and -0.2mm (CC). Intra- and inter-breath-hold uncertainty of tumours and lymph nodes were small in visually guided breath-hold radiotherapy of NSCLC. Target motion could be substantially reduced, but not eliminated, using visually guided DIBH. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. High-resolution MRI in detecting subareolar breast abscess.

    PubMed

    Fu, Peifen; Kurihara, Yasuyuki; Kanemaki, Yoshihide; Okamoto, Kyoko; Nakajima, Yasuo; Fukuda, Mamoru; Maeda, Ichiro

    2007-06-01

    Because subareolar breast abscess has a high recurrence rate, a more effective imaging technique is needed to comprehensively visualize the lesions and guide surgery. We performed a high-resolution MRI technique using a microscopy coil to reveal the characteristics and extent of subareolar breast abscess. High-resolution MRI has potential diagnostic value in subareolar breast abscess. This technique can be used to guide surgery with the aim of reducing the recurrence rate.

  12. A head-mounted display-based personal integrated-image monitoring system for transurethral resection of the prostate.

    PubMed

    Yoshida, Soichiro; Kihara, Kazunori; Takeshita, Hideki; Fujii, Yasuhisa

    2014-12-01

    The head-mounted display (HMD) is a new image monitoring system. We developed the Personal Integrated-image Monitoring System (PIM System) using the HMD (HMZ-T2, Sony Corporation, Tokyo, Japan) in combination with video splitters and multiplexers as a surgical guide system for transurethral resection of the prostate (TURP). The imaging information obtained from the cystoscope, the transurethral ultrasonography (TRUS), the video camera attached to the HMD, and the patient's vital signs monitor were split and integrated by the PIM System and a composite image was displayed by the HMD using a four-split screen technique. Wearing the HMD, the lead surgeon and the assistant could simultaneously and continuously monitor the same information displayed by the HMD in an ergonomically efficient posture. Each participant could independently rearrange the images comprising the composite image depending on the engaging step. Two benign prostatic hyperplasia (BPH) patients underwent TURP performed by surgeons guided with this system. In both cases, the TURP procedure was successfully performed, and their postoperative clinical courses had no remarkable unfavorable events. During the procedure, none of the participants experienced any HMD-wear related adverse effects or reported any discomfort.

  13. Multimodal Medical Image Fusion by Adaptive Manifold Filter.

    PubMed

    Geng, Peng; Liu, Shuaiqi; Zhuang, Shanna

    2015-01-01

    Medical image fusion plays an important role in diagnosis and treatment of diseases such as image-guided radiotherapy and surgery. The modified local contrast information is proposed to fuse multimodal medical images. Firstly, the adaptive manifold filter is introduced into filtering source images as the low-frequency part in the modified local contrast. Secondly, the modified spatial frequency of the source images is adopted as the high-frequency part in the modified local contrast. Finally, the pixel with larger modified local contrast is selected into the fused image. The presented scheme outperforms the guided filter method in spatial domain, the dual-tree complex wavelet transform-based method, nonsubsampled contourlet transform-based method, and four classic fusion methods in terms of visual quality. Furthermore, the mutual information values by the presented method are averagely 55%, 41%, and 62% higher than the three methods and those values of edge based similarity measure by the presented method are averagely 13%, 33%, and 14% higher than the three methods for the six pairs of source images.

  14. Comparing high-resolution microscopy techniques for potential intraoperative use in guiding low-grade glioma resections.

    PubMed

    Meza, Daphne; Wang, Danni; Wang, Yu; Borwege, Sabine; Sanai, Nader; Liu, Jonathan T C

    2015-04-01

    Fluorescence image-guided surgery (FIGS), with contrast provided by 5-ALA-induced PpIX, has been shown to enable a higher extent of resection of high-grade gliomas. However, conventional FIGS with low-power microscopy lacks the sensitivity to aid in low-grade glioma (LGG) resection because PpIX signal is weak and sparse in such tissues. Intraoperative high-resolution microscopy of PpIX fluorescence has been proposed as a method to guide LGG resection, where sub-cellular resolution allows for the visualization of sparse and punctate mitochondrial PpIX production in tumor cells. Here, we assess the performance of three potentially portable high-resolution microscopy techniques that may be used for the intraoperative imaging of human LGG tissue samples with PpIX contrast: high-resolution fiber-optic microscopy (HRFM), high-resolution wide-field microscopy (WFM), and dual-axis confocal (DAC) microscopy. Thick unsectioned human LGG tissue samples (n = 7) with 5-ALA-induced PpIX contrast were imaged using three imaging techniques (HRFM, WFM, DAC). The average signal-to-background ratio (SBR) was then calculated for each imaging modality (5 images per tissue, per modality). HRFM provides the ease of use and portability of a flexible fiber bundle, and is simple and inexpensive to build. However, in most cases (6/7), HRFM is not capable of detecting PpIX signal from LGGs due to high autofluorescence, generated by the fiber bundle under laser illumination at 405 nm, which overwhelms the PpIX signal and impedes its visualization. WFM is a camera-based method possessing high lateral resolution but poor axial resolution, resulting in sub-optimal image contrast. Consistent successful detection of PpIX signal throughout our human LGG tissue samples (n = 7), with an acceptable image contrast (SBR >2), was only achieved using DAC microscopy, which offers superior image resolution and contrast that is comparable to histology, but requires a laser-scanning mechanism to achieve optical sectioning. © 2015 Wiley Periodicals, Inc.

  15. Topography-guided photorefractive keratectomy for irregular astigmatism after small incision lenticule extraction.

    PubMed

    Ivarsen, Anders; Hjortdal, Jesper Ø

    2014-06-01

    To report the outcome of topography-guided photorefractive keratectomy (PRK) after complicated small incision lenticule extraction (SMILE). Retrospective case series of 5 eyes with irregular topography and ghost images after complicated SMILE. All eyes received transepithelial topography-guided PRK. Two eyes were treated with 0.02% mitomycin C. Patients were examined after a minimum of 3 months with evaluation of uncorrected (UDVA) and corrected (CDVA) distance visual acuity, Pentacam tomography (Oculus Optikgeräte, Wetzlar, Germany), and whole-eye aberrometry. In 3 eyes, subjective symptoms were diminished and UDVA, CDVA, topography, and corneal wavefront aberrations were improved. The remaining 2 eyes developed significant haze with worsened topography and wavefront aberrations. One eye experienced a two-line reduction in CDVA. Eyes with haze development had not been treated with mitomycin C. Transepithelial topography-guided PRK may reduce visual symptoms after complicated SMILE if postoperative haze can be controlled. To reduce the risk of haze development, application of mitomycin C may be considered. Copyright 2014, SLACK Incorporated.

  16. Effects of line fiducial parameters and beamforming on ultrasound calibration

    PubMed Central

    Ameri, Golafsoun; Baxter, John S. H.; McLeod, A. Jonathan; Peters, Terry M.; Chen, Elvis C. S.

    2017-01-01

    Abstract. Ultrasound (US)-guided interventions are often enhanced via integration with an augmented reality environment, a necessary component of which is US calibration. Calibration requires the segmentation of fiducials, i.e., a phantom, in US images. Fiducial localization error (FLE) can decrease US calibration accuracy, which fundamentally affects the total accuracy of the interventional guidance system. Here, we investigate the effects of US image reconstruction techniques as well as phantom material and geometry on US calibration. It was shown that the FLE was reduced by 29% with synthetic transmit aperture imaging compared with conventional B-mode imaging in a Z-bar calibration, resulting in a 10% reduction of calibration error. In addition, an evaluation of a variety of calibration phantoms with different geometrical and material properties was performed. The phantoms included braided wire, plastic straws, and polyvinyl alcohol cryogel tubes with different diameters. It was shown that these properties have a significant effect on calibration error, which is a variable based on US beamforming techniques. These results would have important implications for calibration procedures and their feasibility in the context of image-guided procedures. PMID:28331886

  17. Effects of line fiducial parameters and beamforming on ultrasound calibration.

    PubMed

    Ameri, Golafsoun; Baxter, John S H; McLeod, A Jonathan; Peters, Terry M; Chen, Elvis C S

    2017-01-01

    Ultrasound (US)-guided interventions are often enhanced via integration with an augmented reality environment, a necessary component of which is US calibration. Calibration requires the segmentation of fiducials, i.e., a phantom, in US images. Fiducial localization error (FLE) can decrease US calibration accuracy, which fundamentally affects the total accuracy of the interventional guidance system. Here, we investigate the effects of US image reconstruction techniques as well as phantom material and geometry on US calibration. It was shown that the FLE was reduced by 29% with synthetic transmit aperture imaging compared with conventional B-mode imaging in a Z-bar calibration, resulting in a 10% reduction of calibration error. In addition, an evaluation of a variety of calibration phantoms with different geometrical and material properties was performed. The phantoms included braided wire, plastic straws, and polyvinyl alcohol cryogel tubes with different diameters. It was shown that these properties have a significant effect on calibration error, which is a variable based on US beamforming techniques. These results would have important implications for calibration procedures and their feasibility in the context of image-guided procedures.

  18. The influence of stimulus format on drawing—a functional imaging study of decision making in portrait drawing

    PubMed Central

    Miall, R.C.; Nam, Se-Ho; Tchalenko, J.

    2014-01-01

    To copy a natural visual image as a line drawing, visual identification and extraction of features in the image must be guided by top-down decisions, and is usually influenced by prior knowledge. In parallel with other behavioral studies testing the relationship between eye and hand movements when drawing, we report here a functional brain imaging study in which we compared drawing of faces and abstract objects: the former can be strongly guided by prior knowledge, the latter less so. To manipulate the difficulty in extracting features to be drawn, each original image was presented in four formats including high contrast line drawings and silhouettes, and as high and low contrast photographic images. We confirmed the detailed eye–hand interaction measures reported in our other behavioral studies by using in-scanner eye-tracking and recording of pen movements with a touch screen. We also show that the brain activation pattern reflects the changes in presentation formats. In particular, by identifying the ventral and lateral occipital areas that were more highly activated during drawing of faces than abstract objects, we found a systematic increase in differential activation for the face-drawing condition, as the presentation format made the decisions more challenging. This study therefore supports theoretical models of how prior knowledge may influence perception in untrained participants, and lead to experience-driven perceptual modulation by trained artists. PMID:25128710

  19. Determination of optimal ultrasound planes for the initialisation of image registration during endoscopic ultrasound-guided procedures.

    PubMed

    Bonmati, Ester; Hu, Yipeng; Gibson, Eli; Uribarri, Laura; Keane, Geri; Gurusami, Kurinchi; Davidson, Brian; Pereira, Stephen P; Clarkson, Matthew J; Barratt, Dean C

    2018-06-01

    Navigation of endoscopic ultrasound (EUS)-guided procedures of the upper gastrointestinal (GI) system can be technically challenging due to the small fields-of-view of ultrasound and optical devices, as well as the anatomical variability and limited number of orienting landmarks during navigation. Co-registration of an EUS device and a pre-procedure 3D image can enhance the ability to navigate. However, the fidelity of this contextual information depends on the accuracy of registration. The purpose of this study was to develop and test the feasibility of a simulation-based planning method for pre-selecting patient-specific EUS-visible anatomical landmark locations to maximise the accuracy and robustness of a feature-based multimodality registration method. A registration approach was adopted in which landmarks are registered to anatomical structures segmented from the pre-procedure volume. The predicted target registration errors (TREs) of EUS-CT registration were estimated using simulated visible anatomical landmarks and a Monte Carlo simulation of landmark localisation error. The optimal planes were selected based on the 90th percentile of TREs, which provide a robust and more accurate EUS-CT registration initialisation. The method was evaluated by comparing the accuracy and robustness of registrations initialised using optimised planes versus non-optimised planes using manually segmented CT images and simulated ([Formula: see text]) or retrospective clinical ([Formula: see text]) EUS landmarks. The results show a lower 90th percentile TRE when registration is initialised using the optimised planes compared with a non-optimised initialisation approach (p value [Formula: see text]). The proposed simulation-based method to find optimised EUS planes and landmarks for EUS-guided procedures may have the potential to improve registration accuracy. Further work will investigate applying the technique in a clinical setting.

  20. Mechanisms of Percept-Percept and Image-Percept Integration in Vision: Behavioral and Electrophysiological Evidence

    ERIC Educational Resources Information Center

    Dalvit, Silvia; Eimer, Martin

    2011-01-01

    Previous research has shown that the detection of a visual target can be guided not only by the temporal integration of two percepts, but also by integrating a percept and an image held in working memory. Behavioral and event-related brain potential (ERP) measures were obtained in a target detection task that required temporal integration of 2…

Top