Sample records for vivo methods models

  1. Analysis of Endothelial Adherence of Bartonella henselae and Acinetobacter baumannii Using a Dynamic Human Ex Vivo Infection Model

    PubMed Central

    Weidensdorfer, Marko; Chae, Ju Ik; Makobe, Celestine; Stahl, Julia; Averhoff, Beate; Müller, Volker; Schürmann, Christoph; Brandes, Ralf P.; Wilharm, Gottfried; Ballhorn, Wibke; Christ, Sara; Linke, Dirk; Fischer, Doris; Göttig, Stephan

    2015-01-01

    Bacterial adherence determines the virulence of many human-pathogenic bacteria. Experimental approaches elucidating this early infection event in greater detail have been performed using mainly methods of cellular microbiology. However, in vitro infections of cell monolayers reflect the in vivo situation only partially, and animal infection models are not available for many human-pathogenic bacteria. Therefore, ex vivo infection of human organs might represent an attractive method to overcome these limitations. We infected whole human umbilical cords ex vivo with Bartonella henselae or Acinetobacter baumannii under dynamic flow conditions mimicking the in vivo infection situation of human endothelium. For this purpose, methods for quantifying endothelium-adherent wild-type and trimeric autotransporter adhesin (TAA)-deficient bacteria were set up. Data revealed that (i) A. baumannii binds in a TAA-dependent manner to endothelial cells, (ii) this organ infection model led to highly reproducible adherence rates, and furthermore, (iii) this model allowed to dissect the biological function of TAAs in the natural course of human infections. These findings indicate that infection models using ex vivo human tissue samples (“organ microbiology”) might be a valuable tool in analyzing bacterial pathogenicity with the capacity to replace animal infection models at least partially. PMID:26712205

  2. Comparison of in vivo and ex vivo viscoelastic behavior of the spinal cord.

    PubMed

    Ramo, Nicole L; Shetye, Snehal S; Streijger, Femke; Lee, Jae H T; Troyer, Kevin L; Kwon, Brian K; Cripton, Peter; Puttlitz, Christian M

    2018-03-01

    Despite efforts to simulate the in vivo environment, post-mortem degradation and lack of blood perfusion complicate the use of ex vivo derived material models in computational studies of spinal cord injury. In order to quantify the mechanical changes that manifest ex vivo, the viscoelastic behavior of in vivo and ex vivo porcine spinal cord samples were compared. Stress-relaxation data from each condition were fit to a non-linear viscoelastic model using a novel characterization technique called the direct fit method. To validate the presented material models, the parameters obtained for each condition were used to predict the respective dynamic cyclic response. Both ex vivo and in vivo samples displayed non-linear viscoelastic behavior with a significant increase in relaxation with applied strain. However, at all three strain magnitudes compared, ex vivo samples experienced a higher stress and greater relaxation than in vivo samples. Significant differences between model parameters also showed distinct relaxation behaviors, especially in non-linear relaxation modulus components associated with the short-term response (0.1-1 s). The results of this study underscore the necessity of utilizing material models developed from in vivo experimental data for studies of spinal cord injury, where the time-dependent properties are critical. The ability of each material model to accurately predict the dynamic cyclic response validates the presented methodology and supports the use of the in vivo model in future high-resolution finite element modeling efforts. Neural tissues (such as the brain and spinal cord) display time-dependent, or viscoelastic, mechanical behavior making it difficult to model how they respond to various loading conditions, including injury. Methods that aim to characterize the behavior of the spinal cord almost exclusively use ex vivo cadaveric or animal samples, despite evidence that time after death affects the behavior compared to that in a living animal (in vivo response). Therefore, this study directly compared the mechanical response of ex vivo and in vivo samples to quantify these differences for the first time. This will allow researchers to draw more accurate conclusions about spinal cord injuries based on ex vivo data (which are easier to obtain) and emphasizes the importance of future in vivo experimental animal work. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  3. A Rapid and Convenient Method for in Vivo Fluorescent Imaging of Protoscolices of Echinococcus multilocularis.

    PubMed

    Yang, Tao; Wang, Sibo; Zhang, Xuyong; Xia, Jie; Guo, Jun; Hou, Jixue; Zhang, Hongwei; Chen, Xueling; Wu, Xiangwei

    2016-04-01

    Human and animal alveolar echinococcosis (AE) are important helminth infections endemic in wide areas of the Northern hemisphere. Monitoring Echinococcus multilocularis viability and spread using real-time fluorescent imaging in vivo provides a fast method to evaluate the load of parasite. Here, we generated a kind of fluorescent protoscolices in vivo imaging model and utilized this model to assess the activity against E. multilocularis protoscolices of metformin (Met). Results indicated that JC-1 tagged E. multilocularis can be reliably and confidently used to monitor protoscolices in vitro and in vivo. The availability of this transient in vivo fluorescent imaging of E. multilocularis protoscolices constitutes an important step toward the long term bio-imaging research of the AE-infected mouse models. In addition, this will be of great interest for further research on infection strategies and development of drugs and vaccines against E. multilocularis and other cestodes.

  4. Ex vivo rabbit and human corneas as models for bacterial and fungal keratitis.

    PubMed

    Pinnock, Abigail; Shivshetty, Nagaveni; Roy, Sanhita; Rimmer, Stephen; Douglas, Ian; MacNeil, Sheila; Garg, Prashant

    2017-02-01

    In the study of microbial keratitis, in vivo animal models often require a large number of animals, and in vitro monolayer cell culture does not maintain the three-dimensional structure of the tissues or cell-to-cell communication of in vivo models. Here, we propose reproducible ex vivo models of single- and dual-infection keratitis as an alternative to in vivo and in vitro models. Excised rabbit and human corneoscleral rims maintained in organ culture were infected using 10 8 cells of Staphylococcus aureus, Pseudomonas aeruginosa, Candida albicans or Fusarium solani. The infection was introduced by wounding with a scalpel and exposing corneas to the microbial suspension or by intrastromal injection. Post-inoculation, corneas were maintained for 24 and 48 h at 37 °C. After incubation, corneas were either homogenised to determine colony-forming units (CFU)/cornea or processed for histological examination using routine staining methods. Single- and mixed-species infections were compared. We observed a significant increase in CFU after 48 h compared to 24 h with S. aureus and P. aeruginosa. However, no such increase was observed in corneas infected with C. albicans or F. solani. The injection method yielded an approximately two- to 100-fold increase (p < 0.05) in the majority of organisms from infected corneas. Histology of the scalpel-wounded and injection models indicated extensive infiltration of P. aeruginosa throughout the entire cornea, with less infiltration observed for S. aureus, C. albicans and F. solani. The models also supported dual infections. Both scalpel wounding and injection methods are suitable for inducing infection of ex vivo rabbit and human cornea models. These simple and reproducible models will be useful as an alternative to in vitro and in vivo models for investigating the detection and treatment of microbial keratitis, particularly when this might be due to two infective organisms.

  5. Machine Learning Model Analysis and Data Visualization with Small Molecules Tested in a Mouse Model of Mycobacterium tuberculosis Infection (2014–2015)

    PubMed Central

    2016-01-01

    The renewed urgency to develop new treatments for Mycobacterium tuberculosis (Mtb) infection has resulted in large-scale phenotypic screening and thousands of new active compounds in vitro. The next challenge is to identify candidates to pursue in a mouse in vivo efficacy model as a step to predicting clinical efficacy. We previously analyzed over 70 years of this mouse in vivo efficacy data, which we used to generate and validate machine learning models. Curation of 60 additional small molecules with in vivo data published in 2014 and 2015 was undertaken to further test these models. This represents a much larger test set than for the previous models. Several computational approaches have now been applied to analyze these molecules and compare their molecular properties beyond those attempted previously. Our previous machine learning models have been updated, and a novel aspect has been added in the form of mouse liver microsomal half-life (MLM t1/2) and in vitro-based Mtb models incorporating cytotoxicity data that were used to predict in vivo activity for comparison. Our best Mtbin vivo models possess fivefold ROC values > 0.7, sensitivity > 80%, and concordance > 60%, while the best specificity value is >40%. Use of an MLM t1/2 Bayesian model affords comparable results for scoring the 60 compounds tested. Combining MLM stability and in vitroMtb models in a novel consensus workflow in the best cases has a positive predicted value (hit rate) > 77%. Our results indicate that Bayesian models constructed with literature in vivoMtb data generated by different laboratories in various mouse models can have predictive value and may be used alongside MLM t1/2 and in vitro-based Mtb models to assist in selecting antitubercular compounds with desirable in vivo efficacy. We demonstrate for the first time that consensus models of any kind can be used to predict in vivo activity for Mtb. In addition, we describe a new clustering method for data visualization and apply this to the in vivo training and test data, ultimately making the method accessible in a mobile app. PMID:27335215

  6. MR thermometry characterization of a hyperthermia ultrasound array designed using the k-space computational method

    PubMed Central

    Al-Bataineh, Osama M; Collins, Christopher M; Park, Eun-Joo; Lee, Hotaik; Smith, Nadine Barrie

    2006-01-01

    Background Ultrasound induced hyperthermia is a useful adjuvant to radiation therapy in the treatment of prostate cancer. A uniform thermal dose (43°C for 30 minutes) is required within the targeted cancerous volume for effective therapy. This requires specific ultrasound phased array design and appropriate thermometry method. Inhomogeneous, acoustical, three-dimensional (3D) prostate models and economical computational methods provide necessary tools to predict the appropriate shape of hyperthermia phased arrays for better focusing. This research utilizes the k-space computational method and a 3D human prostate model to design an intracavitary ultrasound probe for hyperthermia treatment of prostate cancer. Evaluation of the probe includes ex vivo and in vivo controlled hyperthermia experiments using the noninvasive magnetic resonance imaging (MRI) thermometry. Methods A 3D acoustical prostate model was created using photographic data from the Visible Human Project®. The k-space computational method was used on this coarse grid and inhomogeneous tissue model to simulate the steady state pressure wavefield of the designed phased array using the linear acoustic wave equation. To ensure the uniformity and spread of the pressure in the length of the array, and the focusing capability in the width of the array, the equally-sized elements of the 4 × 20 elements phased array were 1 × 14 mm. A probe was constructed according to the design in simulation using lead zerconate titanate (PZT-8) ceramic and a Delrin® plastic housing. Noninvasive MRI thermometry and a switching feedback controller were used to accomplish ex vivo and in vivo hyperthermia evaluations of the probe. Results Both exposimetry and k-space simulation results demonstrated acceptable agreement within 9%. With a desired temperature plateau of 43.0°C, ex vivo and in vivo controlled hyperthermia experiments showed that the MRI temperature at the steady state was 42.9 ± 0.38°C and 43.1 ± 0.80°C, respectively, for 20 minutes of heating. Conclusion Unlike conventional computational methods, the k-space method provides a powerful tool to predict pressure wavefield in large scale, 3D, inhomogeneous and coarse grid tissue models. Noninvasive MRI thermometry supports the efficacy of this probe and the feedback controller in an in vivo hyperthermia treatment of canine prostate. PMID:17064421

  7. Considerations for ex vivo thermal tissue testing exemplified using the fresh porcine longissimus muscle model for endometrial ablation

    NASA Astrophysics Data System (ADS)

    Fugett, James H.; Bennett, Haydon E.; Shrout, Joshua L.; Coad, James E.

    2017-02-01

    Expansions in minimally invasive medical devices and technologies with thermal mechanisms of action are continuing to advance the practice of medicine. These expansions have led to an increasing need for appropriate animal models to validate and quantify device performance. The planning of these studies should take into consideration a variety of parameters, including the appropriate animal model (test system - ex vivo or in vivo; species; tissue type), treatment conditions (test conditions), predicate device selection (as appropriate, control article), study timing (Day 0 acute to more than Day 90 chronic survival studies), and methods of tissue analysis (tissue dissection - staining methods). These considerations are discussed and illustrated using the fresh extirpated porcine longissimus muscle model for endometrial ablation.

  8. Improved modeling of in vivo confocal Raman data using multivariate curve resolution (MCR) augmentation of ordinary least squares models.

    PubMed

    Hancewicz, Thomas M; Xiao, Chunhong; Zhang, Shuliang; Misra, Manoj

    2013-12-01

    In vivo confocal Raman spectroscopy has become the measurement technique of choice for skin health and skin care related communities as a way of measuring functional chemistry aspects of skin that are key indicators for care and treatment of various skin conditions. Chief among these techniques are stratum corneum water content, a critical health indicator for severe skin condition related to dryness, and natural moisturizing factor components that are associated with skin protection and barrier health. In addition, in vivo Raman spectroscopy has proven to be a rapid and effective method for quantifying component penetration in skin for topically applied skin care formulations. The benefit of such a capability is that noninvasive analytical chemistry can be performed in vivo in a clinical setting, significantly simplifying studies aimed at evaluating product performance. This presumes, however, that the data and analysis methods used are compatible and appropriate for the intended purpose. The standard analysis method used by most researchers for in vivo Raman data is ordinary least squares (OLS) regression. The focus of work described in this paper is the applicability of OLS for in vivo Raman analysis with particular attention given to use for non-ideal data that often violate the inherent limitations and deficiencies associated with proper application of OLS. We then describe a newly developed in vivo Raman spectroscopic analysis methodology called multivariate curve resolution-augmented ordinary least squares (MCR-OLS), a relatively simple route to addressing many of the issues with OLS. The method is compared with the standard OLS method using the same in vivo Raman data set and using both qualitative and quantitative comparisons based on model fit error, adherence to known data constraints, and performance against calibration samples. A clear improvement is shown in each comparison for MCR-OLS over standard OLS, thus supporting the premise that the MCR-OLS method is better suited for general-purpose multicomponent analysis of in vivo Raman spectral data. This suggests that the methodology is more readily adaptable to a wide range of component systems and is thus more generally applicable than standard OLS.

  9. MR thermometry characterization of a hyperthermia ultrasound array designed using the k-space computational method.

    PubMed

    Al-Bataineh, Osama M; Collins, Christopher M; Park, Eun-Joo; Lee, Hotaik; Smith, Nadine Barrie

    2006-10-25

    Ultrasound induced hyperthermia is a useful adjuvant to radiation therapy in the treatment of prostate cancer. A uniform thermal dose (43 degrees C for 30 minutes) is required within the targeted cancerous volume for effective therapy. This requires specific ultrasound phased array design and appropriate thermometry method. Inhomogeneous, acoustical, three-dimensional (3D) prostate models and economical computational methods provide necessary tools to predict the appropriate shape of hyperthermia phased arrays for better focusing. This research utilizes the k-space computational method and a 3D human prostate model to design an intracavitary ultrasound probe for hyperthermia treatment of prostate cancer. Evaluation of the probe includes ex vivo and in vivo controlled hyperthermia experiments using the noninvasive magnetic resonance imaging (MRI) thermometry. A 3D acoustical prostate model was created using photographic data from the Visible Human Project. The k-space computational method was used on this coarse grid and inhomogeneous tissue model to simulate the steady state pressure wavefield of the designed phased array using the linear acoustic wave equation. To ensure the uniformity and spread of the pressure in the length of the array, and the focusing capability in the width of the array, the equally-sized elements of the 4 x 20 elements phased array were 1 x 14 mm. A probe was constructed according to the design in simulation using lead zerconate titanate (PZT-8) ceramic and a Delrin plastic housing. Noninvasive MRI thermometry and a switching feedback controller were used to accomplish ex vivo and in vivo hyperthermia evaluations of the probe. Both exposimetry and k-space simulation results demonstrated acceptable agreement within 9%. With a desired temperature plateau of 43.0 degrees C, ex vivo and in vivo controlled hyperthermia experiments showed that the MRI temperature at the steady state was 42.9 +/- 0.38 degrees C and 43.1 +/- 0.80 degrees C, respectively, for 20 minutes of heating. Unlike conventional computational methods, the k-space method provides a powerful tool to predict pressure wavefield in large scale, 3D, inhomogeneous and coarse grid tissue models. Noninvasive MRI thermometry supports the efficacy of this probe and the feedback controller in an in vivo hyperthermia treatment of canine prostate.

  10. Recent developments in skin mimic systems to predict transdermal permeation.

    PubMed

    Waters, Laura J

    2015-01-01

    In recent years there has been a drive to create experimental techniques that can facilitate the accurate and precise prediction of transdermal permeation without the use of in vivo studies. This review considers why permeation data is essential, provides a brief summary as to how skin acts as a natural barrier to permeation and discusses why in vivo studies are undesirable. This is followed by an in-depth discussion on the extensive range of alternative methods that have been developed in recent years. All of the major 'skin mimic systems' are considered including: in vitro models using synthetic membranes, mathematical models including quantitative structure-permeability relationships (QSPRs), human skin equivalents and chromatographic based methods. All of these model based systems are ideally trying to achieve the same end-point, namely a reliable in vitro-in vivo correlation, i.e. matching non-in vivo obtained data with that from human clinical trials. It is only by achieving this aim, that any new method of obtaining permeation data can be acknowledged as a potential replacement for animal studies, for the determination of transdermal permeation. In this review, the relevance and potential applicability of the various models systems will also be discussed.

  11. An in vivo model of functional and vascularized human brain organoids.

    PubMed

    Mansour, Abed AlFatah; Gonçalves, J Tiago; Bloyd, Cooper W; Li, Hao; Fernandes, Sarah; Quang, Daphne; Johnston, Stephen; Parylak, Sarah L; Jin, Xin; Gage, Fred H

    2018-06-01

    Differentiation of human pluripotent stem cells to small brain-like structures known as brain organoids offers an unprecedented opportunity to model human brain development and disease. To provide a vascularized and functional in vivo model of brain organoids, we established a method for transplanting human brain organoids into the adult mouse brain. Organoid grafts showed progressive neuronal differentiation and maturation, gliogenesis, integration of microglia, and growth of axons to multiple regions of the host brain. In vivo two-photon imaging demonstrated functional neuronal networks and blood vessels in the grafts. Finally, in vivo extracellular recording combined with optogenetics revealed intragraft neuronal activity and suggested graft-to-host functional synaptic connectivity. This combination of human neural organoids and an in vivo physiological environment in the animal brain may facilitate disease modeling under physiological conditions.

  12. Myocardial strains from 3D displacement encoded magnetic resonance imaging

    PubMed Central

    2012-01-01

    Background The ability to measure and quantify myocardial motion and deformation provides a useful tool to assist in the diagnosis, prognosis and management of heart disease. The recent development of magnetic resonance imaging methods, such as harmonic phase analysis of tagging and displacement encoding with stimulated echoes (DENSE), make detailed non-invasive 3D kinematic analyses of human myocardium possible in the clinic and for research purposes. A robust analysis method is required, however. Methods We propose to estimate strain using a polynomial function which produces local models of the displacement field obtained with DENSE. Given a specific polynomial order, the model is obtained as the least squares fit of the acquired displacement field. These local models are subsequently used to produce estimates of the full strain tensor. Results The proposed method is evaluated on a numerical phantom as well as in vivo on a healthy human heart. The evaluation showed that the proposed method produced accurate results and showed low sensitivity to noise in the numerical phantom. The method was also demonstrated in vivo by assessment of the full strain tensor and to resolve transmural strain variations. Conclusions Strain estimation within a 3D myocardial volume based on polynomial functions yields accurate and robust results when validated on an analytical model. The polynomial field is capable of resolving the measured material positions from the in vivo data, and the obtained in vivo strains values agree with previously reported myocardial strains in normal human hearts. PMID:22533791

  13. Modeling the pharmacokinetics of extended release pharmaceutical systems

    NASA Astrophysics Data System (ADS)

    di Muria, Michela; Lamberti, Gaetano; Titomanlio, Giuseppe

    2009-03-01

    The pharmacokinetic (PK) models predict the hematic concentration of drugs after the administration. In compartment modeling, the body is described by a set of interconnected “vessels” or “compartments”; the modeling consisting of transient mass balances. Usually the orally administered drugs were considered as immediately available: this cannot describe the administration of extended-release systems. In this work we added to the traditional compartment models the ability to account for a delay in administration, relating this delay to in vitro data. Firstly, the method was validated, applying the model to the dosage of nicotine by chewing-gum; the model was tuned by in vitro/in vivo data of drugs (divalproex-sodium and diltiazem) with medium-rate release kinetics, then it was applied in describing in vivo evolutions due to the assumption of fast- and slow-release systems. The model reveals itself predictive, the same of a Level A in vitro/in vivo correlation, but being physically based, it is preferable to a purely statistical method.

  14. Gene Delivery to the Airway

    PubMed Central

    Keiser, Nicholas W.; Engelhardt, John F.

    2013-01-01

    This unit describes generation of and gene transfer to several commonly used airway models. Isolation and transduction of primary airway epithelial cells are first described. Next, the preparation of polarized airway epithelial monolayers is outlined. Transduction of these polarized cells is also described. Methods are presented for generation of tracheal xenografts as well as both ex vivo and in vivo gene transfer to these xenografts. Finally, a method for in vivo gene delivery to the lungs of rodents is included. Methods for evaluating transgene expression are given in the support protocols. PMID:23853081

  15. Noninvasive and fast measurement of blood glucose in vivo by near infrared (NIR) spectroscopy

    NASA Astrophysics Data System (ADS)

    Jintao, Xue; Liming, Ye; Yufei, Liu; Chunyan, Li; Han, Chen

    2017-05-01

    This research was to develop a method for noninvasive and fast blood glucose assay in vivo. Near-infrared (NIR) spectroscopy, a more promising technique compared to other methods, was investigated in rats with diabetes and normal rats. Calibration models are generated by two different multivariate strategies: partial least squares (PLS) as linear regression method and artificial neural networks (ANN) as non-linear regression method. The PLS model was optimized individually by considering spectral range, spectral pretreatment methods and number of model factors, while the ANN model was studied individually by selecting spectral pretreatment methods, parameters of network topology, number of hidden neurons, and times of epoch. The results of the validation showed the two models were robust, accurate and repeatable. Compared to the ANN model, the performance of the PLS model was much better, with lower root mean square error of validation (RMSEP) of 0.419 and higher correlation coefficients (R) of 96.22%.

  16. Semi-automated in vivo solid-phase microextraction sampling and the diffusion-based interface calibration model to determine the pharmacokinetics of methoxyfenoterol and fenoterol in rats.

    PubMed

    Yeung, Joanne Chung Yan; de Lannoy, Inés; Gien, Brad; Vuckovic, Dajana; Yang, Yingbo; Bojko, Barbara; Pawliszyn, Janusz

    2012-09-12

    In vivo solid-phase microextraction (SPME) can be used to sample the circulating blood of animals without the need to withdraw a representative blood sample. In this study, in vivo SPME in combination with liquid-chromatography tandem mass spectrometry (LC-MS/MS) was used to determine the pharmacokinetics of two drug analytes, R,R-fenoterol and R,R-methoxyfenoterol, administered as 5 mg kg(-1) i.v. bolus doses to groups of 5 rats. This research illustrates, for the first time, the feasibility of the diffusion-based calibration interface model for in vivo SPME studies. To provide a constant sampling rate as required for the diffusion-based interface model, partial automation of the SPME sampling of the analytes from the circulating blood was accomplished using an automated blood sampling system. The use of the blood sampling system allowed automation of all SPME sampling steps in vivo, except for the insertion and removal of the SPME probe from the sampling interface. The results from in vivo SPME were compared to the conventional method based on blood withdrawal and sample clean up by plasma protein precipitation. Both whole blood and plasma concentrations were determined by the conventional method. The concentrations of methoxyfenoterol and fenoterol obtained by SPME generally concur with the whole blood concentrations determined by the conventional method indicating the utility of the proposed method. The proposed diffusion-based interface model has several advantages over other kinetic calibration models for in vivo SPME sampling including (i) it does not require the addition of a standard into the sample matrix during in vivo studies, (ii) it is simple and rapid and eliminates the need to pre-load appropriate standard onto the SPME extraction phase and (iii) the calibration constant for SPME can be calculated based on the diffusion coefficient, extraction time, fiber length and radius, and size of the boundary layer. In the current study, the experimental calibration constants of 338.9±30 mm(-3) and 298.5±25 mm(-3) are in excellent agreement with the theoretical calibration constants of 307.9 mm(-3) and 316.0 mm(-3) for fenoterol and methoxyfenoterol respectively. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Toxicokinetic and Dosimetry Modeling Tools for Exposure ...

    EPA Pesticide Factsheets

    New technologies and in vitro testing approaches have been valuable additions to risk assessments that have historically relied solely on in vivo test results. Compared to in vivo methods, in vitro high throughput screening (HTS) assays are less expensive, faster and can provide mechanistic insights on chemical action. However, extrapolating from in vitro chemical concentrations to target tissue or blood concentrations in vivo is fraught with uncertainties, and modeling is dependent upon pharmacokinetic variables not measured in in vitro assays. To address this need, new tools have been created for characterizing, simulating, and evaluating chemical toxicokinetics. Physiologically-based pharmacokinetic (PBPK) models provide estimates of chemical exposures that produce potentially hazardous tissue concentrations, while tissue microdosimetry PK models relate whole-body chemical exposures to cell-scale concentrations. These tools rely on high-throughput in vitro measurements, and successful methods exist for pharmaceutical compounds that determine PK from limited in vitro measurements and chemical structure-derived property predictions. These high throughput (HT) methods provide a more rapid and less resource–intensive alternative to traditional PK model development. We have augmented these in vitro data with chemical structure-based descriptors and mechanistic tissue partitioning models to construct HTPBPK models for over three hundred environmental and pharmace

  18. [The in vitro dissolution of total composition of the tablet of rhizomes of Ligusticum chuanxiong components and in vitro-in vivo correlation by the method of area under the absorbance-wavelength curve].

    PubMed

    Lai, Hong-qiang; Hu, Yue; Li, Xiao-dong

    2015-06-01

    To discuss the availability of evaluation on the dissolution studies of the multicomponents in traditional Chinese medicine, the in vitro dissolution of total composition of the tablet of rhizomes of Ligusticum chuanxiong components and its correlation with the in vivo were studied by the method of area under the absorbance-wavelength curve (AUAWC). Taken the tablet of rhizomes of Ligusticum chuanxiong components which is composed of sodium ferulate and ligustrazine hydrochloride as subject model, the dissolution tests were carried out with basket method. The plasma concentrations of tablets in different rats were determined by AUAWC at different interval times. The in vivo absorption percentage was calculated by Wagner-Nelson equation to evaluate the in vitro and in vivo correlation. According to the results, the cumulative dissolution in vitro of total composition of tablets of rhizomes of Ligusticum chuanxiong components at 60 min was 90.65% in water by AUAWC. The in vivo pharmacokinetics is fitted with an one-compartment model. The linear equation based on the cumulative dissolution rate (fr) and absorption percentage (fa) at 5, 10, 20, 30 and 60 min was fa = 0.819 7 fr+0.183 and the correlation coefficient was 0.959 5, which showed a good correlation between the in vitro dissolution and the in vivo absorption percentage. The method of AUAWC can be used accurately, feasibly and conveniently to evaluate the in vitro and in vivo correlation of total composition of tablets of rhizomes of Ligusticum chuanxiong components, which will provide better guidance to study the in vitro and in vivo correlation of sustained release preparation etc under complex system of traditional Chinese medicine in the future.

  19. Skin models for the testing of transdermal drugs

    PubMed Central

    Abd, Eman; Yousef, Shereen A; Pastore, Michael N; Telaprolu, Krishna; Mohammed, Yousuf H; Namjoshi, Sarika; Grice, Jeffrey E; Roberts, Michael S

    2016-01-01

    The assessment of percutaneous permeation of molecules is a key step in the evaluation of dermal or transdermal delivery systems. If the drugs are intended for delivery to humans, the most appropriate setting in which to do the assessment is the in vivo human. However, this may not be possible for ethical, practical, or economic reasons, particularly in the early phases of development. It is thus necessary to find alternative methods using accessible and reproducible surrogates for in vivo human skin. A range of models has been developed, including ex vivo human skin, usually obtained from cadavers or plastic surgery patients, ex vivo animal skin, and artificial or reconstructed skin models. Increasingly, largely driven by regulatory authorities and industry, there is a focus on developing standardized techniques and protocols. With this comes the need to demonstrate that the surrogate models produce results that correlate with those from in vivo human studies and that they can be used to show bioequivalence of different topical products. This review discusses the alternative skin models that have been developed as surrogates for normal and diseased skin and examines the concepts of using model systems for in vitro–in vivo correlation and the demonstration of bioequivalence. PMID:27799831

  20. Developments in Methods for Measuring the Intestinal Absorption of Nanoparticle-Bound Drugs

    PubMed Central

    Liu, Wei; Pan, Hao; Zhang, Caiyun; Zhao, Liling; Zhao, Ruixia; Zhu, Yongtao; Pan, Weisan

    2016-01-01

    With the rapid development of nanotechnology, novel drug delivery systems comprising orally administered nanoparticles (NPs) have been paid increasing attention in recent years. The bioavailability of orally administered drugs has significant influence on drug efficacy and therapeutic dosage, and it is therefore imperative that the intestinal absorption of oral NPs be investigated. This review examines the various literature on the oral absorption of polymeric NPs, and provides an overview of the intestinal absorption models that have been developed for the study of oral nanoparticles. Three major categories of models including a total of eight measurement methods are described in detail (in vitro: dialysis bag, rat gut sac, Ussing chamber, cell culture model; in situ: intestinal perfusion, intestinal loops, intestinal vascular cannulation; in vivo: the blood/urine drug concentration method), and the advantages and disadvantages of each method are contrasted and elucidated. In general, in vitro and in situ methods are relatively convenient but lack accuracy, while the in vivo method is troublesome but can provide a true reflection of drug absorption in vivo. This review summarizes the development of intestinal absorption experiments in recent years and provides a reference for the systematic study of the intestinal absorption of nanoparticle-bound drugs. PMID:27455239

  1. An inverse method to determine the mechanical properties of the iris in vivo

    PubMed Central

    2014-01-01

    Background Understanding the mechanical properties of the iris can help to have an insight into the eye diseases with abnormalities of the iris morphology. Material parameters of the iris were simply calculated relying on the ex vivo experiment. However, the mechanical response of the iris in vivo is different from that ex vivo, therefore, a method was put forward to determine the material parameters of the iris using the optimization method in combination with the finite element method based on the in vivo experiment. Material and methods Ocular hypertension was induced by rapid perfusion to the anterior chamber, during perfusion intraocular pressures in the anterior and posterior chamber were record by sensors, images of the anterior segment were captured by the ultrasonic system. The displacement of the characteristic points on the surface of the iris was calculated. A finite element model of the anterior chamber was developed using the ultrasonic image before perfusion, the multi-island genetic algorithm was employed to determine the material parameters of the iris by minimizing the difference between the finite element simulation and the experimental measurements. Results Material parameters of the iris in vivo were identified as the iris was taken as a nearly incompressible second-order Ogden solid. Values of the parameters μ1, α1, μ2 and α2 were 0.0861 ± 0.0080 MPa, 54.2546 ± 12.7180, 0.0754 ± 0.0200 MPa, and 48.0716 ± 15.7796 respectively. The stability of the inverse finite element method was verified, the sensitivity of the model parameters was investigated. Conclusion Material properties of the iris in vivo could be determined using the multi-island genetic algorithm coupled with the finite element method based on the experiment. PMID:24886660

  2. Efficient in vivo gene editing using ribonucleoproteins in skin stem cells of recessive dystrophic epidermolysis bullosa mouse model.

    PubMed

    Wu, Wenbo; Lu, Zhiwei; Li, Fei; Wang, Wenjie; Qian, Nannan; Duan, Jinzhi; Zhang, Yu; Wang, Fengchao; Chen, Ting

    2017-02-14

    The prokaryotic CRISPR/Cas9 system has recently emerged as a powerful tool for genome editing in mammalian cells with the potential to bring curative therapies to patients with genetic diseases. However, efficient in vivo delivery of this genome editing machinery and indeed the very feasibility of using these techniques in vivo remain challenging for most tissue types. Here, we show that nonreplicable Cas9/sgRNA ribonucleoproteins can be used to correct genetic defects in skin stem cells of postnatal recessive dystrophic epidermolysis bullosa (RDEB) mice. We developed a method to locally deliver Cas9/sgRNA ribonucleoproteins into the skin of postnatal mice. This method results in rapid gene editing in epidermal stem cells. Using this method, we show that Cas9/sgRNA ribonucleoproteins efficiently excise exon80, which covers the point mutation in our RDEB mouse model, and thus restores the correct localization of the collagen VII protein in vivo. The skin blistering phenotype is also significantly ameliorated after treatment. This study provides an in vivo gene correction strategy using ribonucleoproteins as curative treatment for genetic diseases in skin and potentially in other somatic tissues.

  3. An Ultrasound Image-Based Dynamic Fusion Modeling Method for Predicting the Quantitative Impact of In Vivo Liver Motion on Intraoperative HIFU Therapies: Investigations in a Porcine Model

    PubMed Central

    N'Djin, W. Apoutou; Chapelon, Jean-Yves; Melodelima, David

    2015-01-01

    Organ motion is a key component in the treatment of abdominal tumors by High Intensity Focused Ultrasound (HIFU), since it may influence the safety, efficacy and treatment time. Here we report the development in a porcine model of an Ultrasound (US) image-based dynamic fusion modeling method for predicting the effect of in vivo motion on intraoperative HIFU treatments performed in the liver in conjunction with surgery. A speckle tracking method was used on US images to quantify in vivo liver motions occurring intraoperatively during breathing and apnea. A fusion modeling of HIFU treatments was implemented by merging dynamic in vivo motion data in a numerical modeling of HIFU treatments. Two HIFU strategies were studied: a spherical focusing delivering 49 juxtapositions of 5-second HIFU exposures and a toroidal focusing using 1 single 40-second HIFU exposure. Liver motions during breathing were spatially homogenous and could be approximated to a rigid motion mainly encountered in the cranial-caudal direction (f = 0.20Hz, magnitude >13mm). Elastic liver motions due to cardiovascular activity, although negligible, were detectable near millimeter-wide sus-hepatic veins (f = 0.96Hz, magnitude <1mm). The fusion modeling quantified the deleterious effects of respiratory motions on the size and homogeneity of a standard “cigar-shaped” millimetric lesion usually predicted after a 5-second single spherical HIFU exposure in stationary tissues (Dice Similarity Coefficient: DSC<45%). This method assessed the ability to enlarge HIFU ablations during respiration, either by juxtaposing “cigar-shaped” lesions with spherical HIFU exposures, or by generating one large single lesion with toroidal HIFU exposures (DSC>75%). Fusion modeling predictions were preliminarily validated in vivo and showed the potential of using a long-duration toroidal HIFU exposure to accelerate the ablation process during breathing (from 0.5 to 6 cm3·min-1). To improve HIFU treatment control, dynamic fusion modeling may be interesting for assessing numerically focusing strategies and motion compensation techniques in more realistic conditions. PMID:26398366

  4. In vivo Assessment and Potential Diagnosis of Xenobiotics that Perturb the Thyroid Pathway: Proteomic Analysis of Xenopus laevis Brain Tissue following Exposure to Model T4 Inhibitors

    EPA Science Inventory

    As part of a multi-endpoint systems approach to develop comprehensive methods for assessing endocrine stressors in vertebrates, differential protein profiling was used to investigate expression profiles in the brain of an amphibian model (Xenopus laevis) following in vivo exposur...

  5. In vivo acoustic and photoacoustic focusing of circulating cells

    NASA Astrophysics Data System (ADS)

    Galanzha, Ekaterina I.; Viegas, Mark G.; Malinsky, Taras I.; Melerzanov, Alexander V.; Juratli, Mazen A.; Sarimollaoglu, Mustafa; Nedosekin, Dmitry A.; Zharov, Vladimir P.

    2016-03-01

    In vivo flow cytometry using vessels as natural tubes with native cell flows has revolutionized the study of rare circulating tumor cells in a complex blood background. However, the presence of many blood cells in the detection volume makes it difficult to count each cell in this volume. We introduce method for manipulation of circulating cells in vivo with the use of gradient acoustic forces induced by ultrasound and photoacoustic waves. In a murine model, we demonstrated cell trapping, redirecting and focusing in blood and lymph flow into a tight stream, noninvasive wall-free transportation of blood, and the potential for photoacoustic detection of sickle cells without labeling and of leukocytes targeted by functionalized nanoparticles. Integration of cell focusing with intravital imaging methods may provide a versatile biological tool for single-cell analysis in circulation, with a focus on in vivo needleless blood tests, and preclinical studies of human diseases in animal models.

  6. In vivo acoustic and photoacoustic focusing of circulating cells

    PubMed Central

    Galanzha, Ekaterina I.; Viegas, Mark G.; Malinsky, Taras I.; Melerzanov, Alexander V.; Juratli, Mazen A.; Sarimollaoglu, Mustafa; Nedosekin, Dmitry A.; Zharov, Vladimir P.

    2016-01-01

    In vivo flow cytometry using vessels as natural tubes with native cell flows has revolutionized the study of rare circulating tumor cells in a complex blood background. However, the presence of many blood cells in the detection volume makes it difficult to count each cell in this volume. We introduce method for manipulation of circulating cells in vivo with the use of gradient acoustic forces induced by ultrasound and photoacoustic waves. In a murine model, we demonstrated cell trapping, redirecting and focusing in blood and lymph flow into a tight stream, noninvasive wall-free transportation of blood, and the potential for photoacoustic detection of sickle cells without labeling and of leukocytes targeted by functionalized nanoparticles. Integration of cell focusing with intravital imaging methods may provide a versatile biological tool for single-cell analysis in circulation, with a focus on in vivo needleless blood tests, and preclinical studies of human diseases in animal models. PMID:26979811

  7. Reproducibility and Variation of Diffusion Measures in the Squirrel Monkey Brain, In Vivo and Ex Vivo

    PubMed Central

    Schilling, Kurt; Gao, Yurui; Stepniewska, Iwona; Choe, Ann S; Landman, Bennett A; Anderson, Adam W

    2016-01-01

    Purpose Animal models are needed to better understand the relationship between diffusion MRI (dMRI) and the underlying tissue microstructure. One promising model for validation studies is the common squirrel monkey, Saimiri sciureus. This study aims to determine (1) the reproducibility of in vivo diffusion measures both within and between subjects; (2) the agreement between in vivo and ex vivo data acquired from the same specimen and (3) normal diffusion values and their variation across brain regions. Methods Data were acquired from three healthy squirrel monkeys, each imaged twice in vivo and once ex vivo. Reproducibility of fractional anisotropy (FA), mean diffusivity (MD), and principal eigenvector (PEV) was assessed, and normal values were determined both in vivo and ex vivo. Results The calculated coefficients of variation (CVs) for both intra-subject and inter-subject MD were below 10% (low variability) while FA had a wider range of CVs, 2–14% intra-subject (moderate variability), and 3–31% inter-subject (high variability). MD in ex vivo tissue was lower than in vivo (30%–50% decrease), while FA values increased in all regions (30–39% increase). The mode of angular differences between in vivo and ex vivo PEVs was 12 degrees. Conclusion This study characterizes the diffusion properties of the squirrel monkey brain and serves as the groundwork for using the squirrel monkey, both in vivo and ex vivo, as a model for diffusion MRI studies. PMID:27587226

  8. Correcting for deformation in skin-based marker systems.

    PubMed

    Alexander, E J; Andriacchi, T P

    2001-03-01

    A new technique is described that reduces error due to skin movement artifact in the opto-electronic measurement of in vivo skeletal motion. This work builds on a previously described point cluster technique marker set and estimation algorithm by extending the transformation equations to the general deformation case using a set of activity-dependent deformation models. Skin deformation during activities of daily living are modeled as consisting of a functional form defined over the observation interval (the deformation model) plus additive noise (modeling error). The method is described as an interval deformation technique. The method was tested using simulation trials with systematic and random components of deformation error introduced into marker position vectors. The technique was found to substantially outperform methods that require rigid-body assumptions. The method was tested in vivo on a patient fitted with an external fixation device (Ilizarov). Simultaneous measurements from markers placed on the Ilizarov device (fixed to bone) were compared to measurements derived from skin-based markers. The interval deformation technique reduced the errors in limb segment pose estimate by 33 and 25% compared to the classic rigid-body technique for position and orientation, respectively. This newly developed method has demonstrated that by accounting for the changing shape of the limb segment, a substantial improvement in the estimates of in vivo skeletal movement can be achieved.

  9. In-vivo detectability index: development and validation of an automated methodology

    NASA Astrophysics Data System (ADS)

    Smith, Taylor Brunton; Solomon, Justin; Samei, Ehsan

    2017-03-01

    The purpose of this study was to develop and validate a method to estimate patient-specific detectability indices directly from patients' CT images (i.e., "in vivo"). The method works by automatically extracting noise (NPS) and resolution (MTF) properties from each patient's CT series based on previously validated techniques. Patient images are thresholded into skin-air interfaces to form edge-spread functions, which are further binned, differentiated, and Fourier transformed to form the MTF. The NPS is likewise estimated from uniform areas of the image. These are combined with assumed task functions (reference function: 10 mm disk lesion with contrast of -15 HU) to compute detectability indices for a non-prewhitening matched filter model observer predicting observer performance. The results were compared to those from a previous human detection study on 105 subtle, hypo-attenuating liver lesions, using a two-alternative-forcedchoice (2AFC) method, over 6 dose levels using 16 readers. The in vivo detectability indices estimated for all patient images were compared to binary 2AFC outcomes with a generalized linear mixed-effects statistical model (Probit link function, linear terms only, no interactions, random term for readers). The model showed that the in vivo detectability indices were strongly predictive of 2AFC outcomes (P < 0.05). A linear comparison between the human detection accuracy and model-predicted detection accuracy (for like conditions) resulted in Pearson and Spearman correlations coefficients of 0.86 and 0.87, respectively. These data provide evidence that the in vivo detectability index could potentially be used to automatically estimate and track image quality in a clinical operation.

  10. [Application of numerical convolution in in vivo/in vitro correlation research].

    PubMed

    Yue, Peng

    2009-01-01

    This paper introduced the conception and principle of in vivo/in vitro correlation (IVIVC) and convolution/deconvolution methods, and elucidated in details the convolution strategy and method for calculating the in vivo absorption performance of the pharmaceutics according to the their pharmacokinetic data in Excel, then put the results forward to IVIVC research. Firstly, the pharmacokinetic data ware fitted by mathematical software to make up the lost points. Secondly, the parameters of the optimal fitted input function were defined by trail-and-error method according to the convolution principle in Excel under the hypothesis that all the input functions fit the Weibull functions. Finally, the IVIVC between in vivo input function and the in vitro dissolution was studied. In the examples, not only the application of this method was demonstrated in details but also its simplicity and effectiveness were proved by comparing with the compartment model method and deconvolution method. It showed to be a powerful tool for IVIVC research.

  11. Radionuclide-fluorescence Reporter Gene Imaging to Track Tumor Progression in Rodent Tumor Models

    PubMed Central

    Volpe, Alessia; Man, Francis; Lim, Lindsay; Khoshnevisan, Alex; Blower, Julia; Blower, Philip J.; Fruhwirth, Gilbert O.

    2018-01-01

    Metastasis is responsible for most cancer deaths. Despite extensive research, the mechanistic understanding of the complex processes governing metastasis remains incomplete. In vivo models are paramount for metastasis research, but require refinement. Tracking spontaneous metastasis by non-invasive in vivo imaging is now possible, but remains challenging as it requires long-time observation and high sensitivity. We describe a longitudinal combined radionuclide and fluorescence whole-body in vivo imaging approach for tracking tumor progression and spontaneous metastasis. This reporter gene methodology employs the sodium iodide symporter (NIS) fused to a fluorescent protein (FP). Cancer cells are engineered to stably express NIS-FP followed by selection based on fluorescence-activated cell sorting. Corresponding tumor models are established in mice. NIS-FP expressing cancer cells are tracked non-invasively in vivo at the whole-body level by positron emission tomography (PET) using the NIS radiotracer [18F]BF4-. PET is currently the most sensitive in vivo imaging technology available at this scale and enables reliable and absolute quantification. Current methods either rely on large cohorts of animals that are euthanized for metastasis assessment at varying time points, or rely on barely quantifiable 2D imaging. The advantages of the described method are: (i) highly sensitive non-invasive in vivo 3D PET imaging and quantification, (ii) automated PET tracer production, (iii) a significant reduction in required animal numbers due to repeat imaging options, (iv) the acquisition of paired data from subsequent imaging sessions providing better statistical data, and (v) the intrinsic option for ex vivo confirmation of cancer cells in tissues by fluorescence microscopy or cytometry. In this protocol, we describe all steps required for routine NIS-FP-afforded non-invasive in vivo cancer cell tracking using PET/CT and ex vivo confirmation of in vivo results. This protocol has applications beyond cancer research whenever in vivo localization, expansion and long-time monitoring of a cell population is of interest. PMID:29608157

  12. Optical imaging of RNAi-mediated silencing of cancer

    NASA Astrophysics Data System (ADS)

    Ochiya, Takahiro; Honma, Kimi; Takeshita, Fumitaka; Nagahara, Shunji

    2008-02-01

    RNAi has rapidly become a powerful tool for drug target discovery and validation in an in vitro culture system and, consequently, interest is rapidly growing for extension of its application to in vivo systems, such as animal disease models and human therapeutics. Cancer is one obvious application for RNAi therapeutics, because abnormal gene expression is thought to contribute to the pathogenesis and maintenance of the malignant phenotype of cancer and thereby many oncogenes and cell-signaling molecules present enticing drug target possibilities. RNAi, potent and specific, could silence tumor-related genes and would appear to be a rational approach to inhibit tumor growth. In subsequent in vivo studies, the appropriate cancer model must be developed for an evaluation of siRNA effects on tumors. How to evaluate the effect of siRNA in an in vivo therapeutic model is also important. Accelerating the analyses of these models and improving their predictive value through whole animal imaging methods, which provide cancer inhibition in real time and are sensitive to subtle changes, are crucial for rapid advancement of these approaches. Bioluminescent imaging is one of these optically based imaging methods that enable rapid in vivo analyses of a variety of cellular and molecular events with extreme sensitivity.

  13. Chest drainage teaching and training for medical students. Use of a surgical ex vivo pig model.

    PubMed

    Tube, Milton Ignacio Carvalho; Netto, Fernando Antonio Campelo Spencer; Costa, Elaine; Lafayette, Daniell de Siqueira Araújo; Lima, George Augusto da Fonseca Carvalho Antunes; Menezes, Jamile Isabela Santos de; Aires, Vinicius Gueiros Buenos; Ferraz, Álvaro Antônio Bandeira; Campos, Josemberg Marins; Moraes, Fernando Ribeiro de

    2016-05-01

    Implement a constructivist approach in thoracic drainage training in surgical ex vivo pig models, to compare the acquisition of homogeneous surgical skills between medical students. Experimental study, prospective, transversal, analytical, controlled, three steps. Selection, training, evaluation. a) students without training in thoracic drainage; b) without exposure to constructivist methodology. 2) EXCLUSION CRITERIA: a) students developed surgical skills; b) a history of allergy. (N = 312). Two groups participated in the study: A and B. Lecture equal for both groups. Differentiated teaching: group A, descriptive and informative method; group B, learning method based on problems. A surgical ex vivo pig model for training the chest drain was created. Were applied pre and post-test, test goal-discursive and OSATS scale. Theoretical averages: Group A = 9.5 ± 0.5; Group B = 8.8 ± 1.1 (p = 0.006). Medium Practices: Group A = 22.8 ± 1.8; Group B = 23.0 ± 2.8 (p <0.001). Through the constructivist methodology implemented in the thoracic drainage training in surgical ex vivo pig models, has proven the acquisition of surgical skills homogeneous compared among medical students.

  14. Analysis methods and recent advances in nonlinear pharmacokinetics from in vitro through in loci to in vivo.

    PubMed

    Yamaoka, Kiyoshi; Takakura, Yoshinobu

    2004-12-01

    An attempt has been made to review the nonlinearities in the disposition in vitro, in situ, in loci and in vivo mainly from a theoretical point of view. Parallel Michaelis-Menten and linear (first-order) eliminations are often observed in the cellular uptake, metabolism and efflux of drugs. The well-stirred and parallel-tube models are mainly adopted under steady-state conditions in perfusion experiments, whereas distribution, tank-in-series and dispersion models are often used under nonsteady-state conditions with a pulse input. The analysis of the nonlinear local disposition in loci is reviewed from two points of view, namely an indirect method involving physiologically based pharmacokinetics (PBPK) and a direct (two or three samplings) method using live animals. The nonlinear global pharmacokinetics in vivo is reviewed with regard to absorption, elimination (metabolism and excretion) and distribution.

  15. Quantitative in vivo receptor binding. III. Tracer kinetic modeling of muscarinic cholinergic receptor binding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frey, K.A.; Hichwa, R.D.; Ehrenkaufer, R.L.

    1985-10-01

    A tracer kinetic method is developed for the in vivo estimation of high-affinity radioligand binding to central nervous system receptors. Ligand is considered to exist in three brain pools corresponding to free, nonspecifically bound, and specifically bound tracer. These environments, in addition to that of intravascular tracer, are interrelated by a compartmental model of in vivo ligand distribution. A mathematical description of the model is derived, which allows determination of regional blood-brain barrier permeability, nonspecific binding, the rate of receptor-ligand association, and the rate of dissociation of bound ligand, from the time courses of arterial blood and tissue tracer concentrations.more » The term ''free receptor density'' is introduced to describe the receptor population measured by this method. The technique is applied to the in vivo determination of regional muscarinic acetylcholine receptors in the rat, with the use of (TH)scopolamine. Kinetic estimates of free muscarinic receptor density are in general agreement with binding capacities obtained from previous in vivo and in vitro equilibrium binding studies. In the striatum, however, kinetic estimates of free receptor density are less than those in the neocortex--a reversal of the rank ordering of these regions derived from equilibrium determinations. A simplified model is presented that is applicable to tracers that do not readily dissociate from specific binding sites during the experimental period.« less

  16. Feasibility of Using a Novel 2.45 GHz Double Short Distance Slot Coaxial Antenna for Minimally Invasive Cancer Breast Microwave Ablation Therapy: Computational Model, Phantom, and In Vivo Swine Experimentation

    PubMed Central

    Cepeda Rubio, M. F. J.; Leija, L.

    2018-01-01

    Microwave ablation (MWA) by using coaxial antennas is a promising alternative for breast cancer treatment. A double short distance slot coaxial antenna as a newly optimized applicator for minimally invasive treatment of breast cancer is proposed. To validate and to analyze the feasibility of using this method in clinical treatment, a computational model, phantom, and breast swine in vivo experimentation were carried out, by using four microwave powers (50 W, 30 W, 20 W, and 10 W). The finite element method (FEM) was used to develop the computational model. Phantom experimentation was carried out in breast phantom. The in vivo experimentation was carried out in a 90 kg swine sow. Tissue damage was estimated by comparing control and treated micrographs of the porcine mammary gland samples. The coaxial slot antenna was inserted in swine breast glands by using image-guided ultrasound. In all cases, modeling, in vivo and phantom experimentation, and ablation temperatures (above 60°C) were reached. The in vivo experiments suggest that this new MWA applicator could be successfully used to eliminate precise and small areas of tissue (around 20–30 mm2). By modulating the power and time applied, it may be possible to increase/decrease the ablation area. PMID:29854360

  17. Ultrasound thermography: A new temperature reconstruction model and in vivo results

    NASA Astrophysics Data System (ADS)

    Bayat, Mahdi; Ballard, John R.; Ebbini, Emad S.

    2017-03-01

    The recursive echo strain filter (RESF) model is presented as a new echo shift-based ultrasound temperature estimation model. The model is shown to have an infinite impulse response (IIR) filter realization of a differentitor-integrator operator. This model is then used for tracking sub-therapeutic temperature changes due to high intensity focused ultrasound (HIFU) shots in the hind limb of the Copenhagen rats in vivo. In addition to the reconstruction filter, a motion compensation method is presented which takes advantage of the deformation field outside the region of interest to correct the motion errors during temperature tracking. The combination of the RESF model and motion compensation algorithm is shown to greatly enhance the accuracy of the in vivo temperature estimation using ultrasound echo shifts.

  18. Comparison of temporal and spectral scattering methods using acoustically large breast models derived from magnetic resonance images.

    PubMed

    Hesford, Andrew J; Tillett, Jason C; Astheimer, Jeffrey P; Waag, Robert C

    2014-08-01

    Accurate and efficient modeling of ultrasound propagation through realistic tissue models is important to many aspects of clinical ultrasound imaging. Simplified problems with known solutions are often used to study and validate numerical methods. Greater confidence in a time-domain k-space method and a frequency-domain fast multipole method is established in this paper by analyzing results for realistic models of the human breast. Models of breast tissue were produced by segmenting magnetic resonance images of ex vivo specimens into seven distinct tissue types. After confirming with histologic analysis by pathologists that the model structures mimicked in vivo breast, the tissue types were mapped to variations in sound speed and acoustic absorption. Calculations of acoustic scattering by the resulting model were performed on massively parallel supercomputer clusters using parallel implementations of the k-space method and the fast multipole method. The efficient use of these resources was confirmed by parallel efficiency and scalability studies using large-scale, realistic tissue models. Comparisons between the temporal and spectral results were performed in representative planes by Fourier transforming the temporal results. An RMS field error less than 3% throughout the model volume confirms the accuracy of the methods for modeling ultrasound propagation through human breast.

  19. Modeling the spatiotemporal dynamics of light and heat propagation for in vivo optogenetics

    PubMed Central

    Stujenske, Joseph M.; Spellman, Timothy; Gordon, Joshua A.

    2015-01-01

    Summary Despite the increasing use of optogenetics in vivo, the effects of direct light exposure to brain tissue are understudied. Of particular concern is the potential for heat induced by prolonged optical stimulation. We demonstrate that high intensity light, delivered through an optical fiber, is capable of elevating firing rate locally, even in the absence of opsin expression. Predicting the severity and spatial extent of any temperature increase during optogenetic stimulation is therefore of considerable importance. Here we describe a realistic model that simulates light and heat propagation during optogenetic experiments. We validated the model by comparing predicted and measured temperature changes in vivo. We further demonstrate the utility of this model by comparing predictions for various wavelengths of light and fiber sizes, as well as testing methods for reducing heat effects on neural targets in vivo. PMID:26166563

  20. Comparison of multiple enzyme activatable near infrared fluorescent molecular probes for detection and quantification of inflammation in murine colitis models

    PubMed Central

    Ding, Shengli; Blue, Randal E.; Morgan, Douglas R.; Lund, Pauline K.

    2015-01-01

    Background Activatable near-infrared fluorescent (NIRF) probes have been used for ex vivo and in vivo detection of intestinal tumors in animal models. We hypothesized that NIRF probes activatable by cathepsins or MMPs will detect and quantify dextran sulphate sodium (DSS) induced acute colonic inflammation in wild type (WT) mice or chronic colitis in IL-10 null mice ex vivo or in vivo. Methods WT mice given DSS, water controls and IL-10 null mice with chronic colitis were administered probes by retro-orbital injection. FMT2500 LX system imaged fresh and fixed intestine ex vivo and mice in vivo. Inflammation detected by probes was verified by histology and colitis scoring. NIRF signal intensity was quantified using 2D region of interest (ROI) ex vivo or 3D ROI-analysis in vivo. Results Ex vivo, seven probes tested yielded significant higher NIRF signals in colon of DSS treated mice versus controls. A subset of probes was tested in IL-10 null mice and yielded strong ex vivo signals. Ex vivo fluorescence signal with 680 series probes was preserved after formalin fixation. In DSS and IL-10 null models, ex vivo NIRF signal strongly and significantly correlated with colitis scores. In vivo, ProSense680, CatK680FAST and MMPsense680 yielded significantly higher NIRF signals in DSS treated mice than controls but background was high in controls. Conclusion Both cathepsin or MMP-activated NIRF-probes can detect and quantify colonic inflammation ex vivo. ProSense680 yielded the strongest signals in DSS colitis ex vivo and in vivo, but background remains a problem for in vivo quantification of colitis. PMID:24374874

  1. Validating CFD Predictions of Pharmaceutical Aerosol Deposition with In Vivo Data

    PubMed Central

    Tian, Geng; Hindle, Michael; Lee, Sau; Longest, P. Worth

    2015-01-01

    Purpose CFD provides a powerful approach to evaluate the deposition of pharmaceutical aerosols; however, previous studies have not compared CFD results of deposition throughout the lungs with in vivo data. Methods The in vivo datasets selected for comparison with CFD predictions included fast and slow clearance of monodisperse aerosols as well as 2D gamma scintigraphy measurements for a dry powder inhaler (DPI) and softmist inhaler (SMI). The CFD model included the inhaler, a characteristic model of the mouth-throat (MT) and upper tracheobronchial (TB) airways, stochastic individual pathways (SIPs) representing the remaining TB region, and recent CFD-based correlations to predict pharmaceutical aerosol deposition in the alveolar airways. Results For the monodisperse aerosol, CFD predictions of total lung deposition agreed with in vivo data providing a percent relative error of 6% averaged across aerosol sizes of 1-7μm. With the DPI and SMI, deposition was evaluated in the MT, central airways (bifurcations B1-B7), and intermediate plus peripheral airways (B8 through alveoli). Across these regions, CFD predictions produced an average relative error <10% for each inhaler. Conclusions CFD simulations with the SIP modeling approach were shown to accurately predict regional deposition throughout the lungs for multiple aerosol types and different in vivo assessment methods. PMID:25944585

  2. [A method for rapid extracting three-dimensional root model of vivo tooth from cone beam computed tomography data based on the anatomical characteristics of periodontal ligament].

    PubMed

    Zhao, Y J; Wang, S W; Liu, Y; Wang, Y

    2017-02-18

    To explore a new method for rapid extracting and rebuilding three-dimensional (3D) digital root model of vivo tooth from cone beam computed tomography (CBCT) data based on the anatomical characteristics of periodontal ligament, and to evaluate the extraction accuracy of the method. In the study, 15 extracted teeth (11 with single root, 4 with double roots) were collected from oral clinic and 3D digital root models of each tooth were obtained by 3D dental scanner with a high accuracy 0.02 mm in STL format. CBCT data for each patient were acquired before tooth extraction, DICOM data with a voxel size 0.3 mm were input to Mimics 18.0 software. Segmentation, Morphology operations, Boolean operations and Smart expanded function in Mimics software were used to edit teeth, bone and periodontal ligament threshold mask, and root threshold mask were automatically acquired after a series of mask operations. 3D digital root models were extracted in STL format finally. 3D morphology deviation between the extracted root models and corresponding vivo root models were compared in Geomagic Studio 2012 software. The 3D size errors in long axis, bucco-lingual direction and mesio-distal direction were also calculated. The average value of the 3D morphology deviation for 15 roots by calculating Root Mean Square (RMS) value was 0.22 mm, the average size errors in the mesio-distal direction, the bucco-lingual direction and the long axis were 0.46 mm, 0.36 mm and -0.68 mm separately. The average time of this new method for extracting single root was about 2-3 min. It could meet the accuracy requirement of the root 3D reconstruction fororal clinical use. This study established a new method for rapid extracting 3D root model of vivo tooth from CBCT data. It could simplify the traditional manual operation and improve the efficiency and automation of single root extraction. The strategy of this method for complete dentition extraction needs further research.

  3. Mimicking brain tissue binding in an in vitro model of the blood-brain barrier illustrates differences between in vitro and in vivo methods for assessing the rate of brain penetration.

    PubMed

    Heymans, Marjolein; Sevin, Emmanuel; Gosselet, Fabien; Lundquist, Stefan; Culot, Maxime

    2018-06-01

    Assessing the rate of drug delivery to the central nervous system (CNS) in vitro has been used for decades to predict whether CNS drug candidates are likely to attain their pharmacological targets, located within the brain parenchyma, at an effective dose. The predictive value of in vitro blood-brain barrier (BBB) models is therefore frequently assessed by comparing in vitro BBB permeability, usually quoted as the endothelial permeability coefficient (P e ) or apparent permeability (P app ), to their rate of BBB permeation measured in vivo, the latter being commonly assessed in rodents. In collaboration with AstraZeneca (DMPK department, Södertälje, Sweden), the in vitro BBB permeability (P app and P e ) of 27 marketed CNS drugs has been determined using a bovine in vitro BBB model and compared to their in vivo permeability (P vivo ), obtained by rat in-situ brain perfusion. The latter was taken from published data from Summerfield et al. (2007). This comparison confirmed previous reports, showing a strong in vitro/in vivo correlation for hydrophilic compounds, characterized by low brain tissue binding and a weak correlation for lipophilic compounds, characterized by high brain tissue binding. This observation can be explained by the influence of brain tissue binding on the uptake of drugs into the CNS in vivo and the absence of possible brain tissue binding in vitro. The use of glial cells (GC) in the in vitro BBB model to mimic brain tissue binding and the introduction of a new calculation method for in vitro BBB permeability (P vitro ) resulted in a strong correlation between the in vitro and in vivo rate of BBB permeation for the whole set of compounds. These findings might facilitate further in vitro to in vivo extrapolation for CNS drug candidates. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  4. [Ideas and methods on efficient screening of traditional medicines for anti-osteoporosis activity based on M-Act/Tox integrated evaluation using zebrafish].

    PubMed

    Wang, Mo; Ling, Jie; Chen, Ying; Song, Jie; Sun, E; Shi, Zi-Qi; Feng, Liang; Jia, Xiao-Bin; Wei, Ying-Jie

    2017-11-01

    The increasingly apparent liver injury problems of bone strengthening Chinese medicines have brought challenges for clinical application, and it is necessary to consider both effectiveness and safety in screening anti-osteoporosis Chinese medicines. Metabolic transformation is closely related to drug efficacy and toxicity, so it is significant to comprehensively consider metabolism-action/toxicity(M-Act/Tox) for screening anti-osteoporosis Chinese medicines. The current evaluation models and the number of compounds(including metabolites) severely restrict efficient screening in vivo. By referring to previous relevant research and domestic and abroad literature, zebrafish M-Act/Tox integrative method was put forward for efficiently screening anti-osteoporosis herb medicines, which has organically integrated zebrafish metabolism model, osteoporosis model and toxicity evaluation method. This method can break through the bottleneck and blind spots that trace compositions can't achieve efficient and integrated in vivo evaluation, and realize both efficient and comprehensive screening on anti-osteoporosis traditional medicines based on in vivo process taking both safety and effectiveness into account, which is significant to accelerate discovery of effective and safe innovative traditional Chinese medicines for osteoporosis. Copyright© by the Chinese Pharmaceutical Association.

  5. A validated method for modeling anthropoid hip abduction in silico.

    PubMed

    Hammond, Ashley S; Plavcan, J Michael; Ward, Carol V

    2016-07-01

    The ability to reconstruct hip joint mobility from femora and pelves could provide insight into the locomotion and paleobiology of fossil primates. This study presents a method for modeling hip abduction in anthropoids validated with in vivo data. Hip abduction simulations were performed on a large sample of anthropoids. The modeling approach integrates three-dimensional (3D) polygonal models created from laser surface scans of bones, 3D landmark data, and shape analysis software to digitally articulate and manipulate the hip joint. Range of femoral abduction (degrees) and the abducted knee position (distance spanned at the knee during abduction) were compared with published live animal data. The models accurately estimate knee position and (to a lesser extent) angular abduction across broad locomotor groups. They tend to underestimate abduction for acrobatic or suspensory taxa, but overestimate it in more stereotyped taxa. Correspondence between in vivo and in silico data varies at the specific and generic level. Our models broadly correspond to in vivo data on hip abduction, although the relationship between the models and live animal data is less straightforward than hypothesized. The models can predict acrobatic or stereotyped locomotor adaptation for taxa with values near the extremes of the range of abduction ability. Our findings underscore the difficulties associated with modeling complex systems and the importance of validating in silico models. They suggest that models of joint mobility can offer additional insight into the functional abilities of extinct primates when done in consideration of how joints move and function in vivo. Am J Phys Anthropol 160:529-548, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  6. Microwave Ablation: Comparison of Simultaneous and Sequential Activation of Multiple Antennas in Liver Model Systems

    PubMed Central

    Harari, Colin M.; Magagna, Michelle; Bedoya, Mariajose; Lee, Fred T.; Lubner, Meghan G.; Hinshaw, J. Louis; Ziemlewicz, Timothy

    2016-01-01

    Purpose To compare microwave ablation zones created by using sequential or simultaneous power delivery in ex vivo and in vivo liver tissue. Materials and Methods All procedures were approved by the institutional animal care and use committee. Microwave ablations were performed in both ex vivo and in vivo liver models with a 2.45-GHz system capable of powering up to three antennas simultaneously. Two- and three-antenna arrays were evaluated in each model. Sequential and simultaneous ablations were created by delivering power (50 W ex vivo, 65 W in vivo) for 5 minutes per antenna (10 and 15 minutes total ablation time for sequential ablations, 5 minutes for simultaneous ablations). Thirty-two ablations were performed in ex vivo bovine livers (eight per group) and 28 in the livers of eight swine in vivo (seven per group). Ablation zone size and circularity metrics were determined from ablations excised postmortem. Mixed effects modeling was used to evaluate the influence of power delivery, number of antennas, and tissue type. Results On average, ablations created by using the simultaneous power delivery technique were larger than those with the sequential technique (P < .05). Simultaneous ablations were also more circular than sequential ablations (P = .0001). Larger and more circular ablations were achieved with three antennas compared with two antennas (P < .05). Ablations were generally smaller in vivo compared with ex vivo. Conclusion The use of multiple antennas and simultaneous power delivery creates larger, more confluent ablations with greater temperatures than those created with sequential power delivery. © RSNA, 2015 PMID:26133361

  7. In vivo Magnetic Resonance Imaging of Tumor Protease Activity

    PubMed Central

    Haris, Mohammad; Singh, Anup; Mohammed, Imran; Ittyerah, Ranjit; Nath, Kavindra; Nanga, Ravi Prakash Reddy; Debrosse, Catherine; Kogan, Feliks; Cai, Kejia; Poptani, Harish; Reddy, Damodar; Hariharan, Hari; Reddy, Ravinder

    2014-01-01

    Increased expression of cathepsins has diagnostic as well as prognostic value in several types of cancer. Here, we demonstrate a novel magnetic resonance imaging (MRI) method, which uses poly-L-glutamate (PLG) as an MRI probe to map cathepsin expression in vivo, in a rat brain tumor model. This noninvasive, high-resolution and non-radioactive method exploits the differences in the CEST signals of PLG in the native form and cathepsin mediated cleaved form. The method was validated in phantoms with known physiological concentrations, in tumor cells and in an animal model of brain tumor along with immunohistochemical analysis. Potential applications in tumor diagnosis and evaluation of therapeutic response are outlined. PMID:25124082

  8. Toxicokinetic Triage for Environmental Chemicals | Science ...

    EPA Pesticide Factsheets

    Toxicokinetic (TK) models are essential for linking administered doses to blood and tissue concentrations. In vitro-to-in vivo extrapolation (IVIVE) methods have been developed to determine TK from limited in vitro measurements and chemical structure-based property predictions, providing a less resource–intensive alternative to traditional in vivo TK approaches. High throughput TK (HTTK) methods use IVIVE to estimate doses that produce steady-state plasma concentrations equivalent to those producing biological activity in in vitro screening studies (e.g., ToxCast). In this study, the domain of applicability and assumptions of HTTK approaches were evaluated using both in vivo data and simulation analysis. Based on in vivo data for 87 chemicals, specific properties (e.g., in vitro HTTK data, physico-chemical descriptors, chemical structure, and predicted transporter affinities) were identified that correlate with poor HTTK predictive ability. For 350 xenobiotics with literature HTTK data, we then differentiated those xenobiotics for which HTTK approaches are likely to be sufficient, from those that may require additional data. For 272 chemicals we also developed a HT physiologically-based TK (HTPBTK) model that requires somewhat greater information than a steady-state model, but allows non-steady state dynamics and can predict chemical concentration time-courses for a variety of exposure scenarios, tissues, and species. We used this HTPBTK model to show that the

  9. Clinical implementation and rapid commissioning of an EPID based in-vivo dosimetry system.

    PubMed

    Hanson, Ian M; Hansen, Vibeke N; Olaciregui-Ruiz, Igor; van Herk, Marcel

    2014-10-07

    Using an Electronic Portal Imaging Device (EPID) to perform in-vivo dosimetry is one of the most effective and efficient methods of verifying the safe delivery of complex radiotherapy treatments. Previous work has detailed the development of an EPID based in-vivo dosimetry system that was subsequently used to replace pre-treatment dose verification of IMRT and VMAT plans. Here we show that this system can be readily implemented on a commercial megavoltage imaging platform without modification to EPID hardware and without impacting standard imaging procedures. The accuracy and practicality of the EPID in-vivo dosimetry system was confirmed through a comparison with traditional TLD in-vivo measurements performed on five prostate patients.The commissioning time required for the EPID in-vivo dosimetry system was initially prohibitive at approximately 10 h per linac. Here we present a method of calculating linac specific EPID dosimetry correction factors that allow a single energy specific commissioning model to be applied to EPID data from multiple linacs. Using this method reduced the required per linac commissioning time to approximately 30 min.The validity of this commissioning method has been tested by analysing in-vivo dosimetry results of 1220 patients acquired on seven linacs over a period of 5 years. The average deviation between EPID based isocentre dose and expected isocentre dose for these patients was (-0.7  ±  3.2)%.EPID based in-vivo dosimetry is now the primary in-vivo dosimetry tool used at our centre and has replaced nearly all pre-treatment dose verification of IMRT treatments.

  10. Clinical implementation and rapid commissioning of an EPID based in-vivo dosimetry system

    NASA Astrophysics Data System (ADS)

    Hanson, Ian M.; Hansen, Vibeke N.; Olaciregui-Ruiz, Igor; van Herk, Marcel

    2014-10-01

    Using an Electronic Portal Imaging Device (EPID) to perform in-vivo dosimetry is one of the most effective and efficient methods of verifying the safe delivery of complex radiotherapy treatments. Previous work has detailed the development of an EPID based in-vivo dosimetry system that was subsequently used to replace pre-treatment dose verification of IMRT and VMAT plans. Here we show that this system can be readily implemented on a commercial megavoltage imaging platform without modification to EPID hardware and without impacting standard imaging procedures. The accuracy and practicality of the EPID in-vivo dosimetry system was confirmed through a comparison with traditional TLD in-vivo measurements performed on five prostate patients. The commissioning time required for the EPID in-vivo dosimetry system was initially prohibitive at approximately 10 h per linac. Here we present a method of calculating linac specific EPID dosimetry correction factors that allow a single energy specific commissioning model to be applied to EPID data from multiple linacs. Using this method reduced the required per linac commissioning time to approximately 30 min. The validity of this commissioning method has been tested by analysing in-vivo dosimetry results of 1220 patients acquired on seven linacs over a period of 5 years. The average deviation between EPID based isocentre dose and expected isocentre dose for these patients was (-0.7  ±  3.2)%. EPID based in-vivo dosimetry is now the primary in-vivo dosimetry tool used at our centre and has replaced nearly all pre-treatment dose verification of IMRT treatments.

  11. A numerical model to reproduce squeaking of ceramic-on-ceramic total hip arthroplasty. Influence of design and material.

    PubMed

    Piriou, P; Ouenzerfi, G; Migaud, H; Renault, E; Massi, F; Serrault, M

    2016-06-01

    Modern ceramic (CoC) bearings for hip arthroplasty (THA) have been used in younger patients who expect improved survivorship. However, audible squeaking produced by the implant is an annoying complication. Previous numerical simulations were not able to accurately reproduce in vitro and in vivo observations. Therefore, we developed a finite element model to: (1) reproduce in vitro squeaking and validate the model by comparing it with in vivo recordings, (2) determine why there are differences between in vivo and in vitro squeaking frequencies, (3) identify the stem's role in this squeaking, (4) predict which designs and materials are more likely to produce squeaking. A CoC THA numerical model can be developed that reproduces the squeaking frequencies observed in vivo. Numerical methods (finite element analysis [ANSYS]) and experimental methods (using a non-lubricated simulated hip with a cementless 32mm CoC THA) were developed to reproduce squeaking. Numerical analysis was performed to identify the frequencies that cause vibrations perceived as an acoustic emission. The finite element analysis (FEA) model was enhanced by adjusting periprosthetic bone and soft tissue elements in order to reproduce the squeaking frequencies recorded in vivo. A numerical method (complex eigenvalue analysis) was used to find the acoustic frequencies of the squeaking noise. The frequencies obtained from the model and the hip simulator were compared to those recorded in vivo. The numerical results were validated by experiments with the laboratory hip simulator. The frequencies obtained (mean 2790Hz with FEA, 2755Hz with simulator, decreasing to 1759Hz when bone and soft tissue were included in the FEA) were consistent with those of squeaking hips recorded in vivo (1521Hz). The cup and ceramic insert were the source of the vibration, but had little influence on the diffusion of the noise required to make the squeaking audible to the human ear. The FEA showed that diffusion of squeaking was due to an unstable vibration of the stem during frictional contact. The FEA predicted a higher rate of squeaking (at a lower coefficient of friction) when TZMF™ alloy is used instead of Ti6Al4V and when an anatomic press-fit stem is used instead of straight self-locking designs. The current FEA model is reliable; it can be used to assess various stem designs and alloys to predict the different rates of squeaking that certain stems will likely produce. Level IV in vitro study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  12. Heat effects on drug delivery across human skin

    PubMed Central

    Hao, Jinsong; Ghosh, Priyanka; Li, S. Kevin; Newman, Bryan; Kasting, Gerald B.; Raney, Sam G.

    2016-01-01

    Introduction Exposure to heat can impact the clinical efficacy and/or safety of transdermal and topical drug products. Understanding these heat effects and designing meaningful in vitro and in vivo methods to study them are of significant value to the development and evaluation of drug products dosed to the skin. Areas covered This review provides an overview of the underlying mechanisms and the observed effects of heat on the skin and on transdermal/topical drug delivery, thermoregulation and heat tolerability. The designs of several in vitro and in vivo heat effect studies and their results are reviewed. Expert opinion There is substantial evidence that elevated temperature can increase transdermal/topical drug delivery. However, in vitro and in vivo methods reported in the literature to study heat effects of transdermal/topical drug products have utilized inconsistent study conditions, and in vitro models require better characterization. Appropriate study designs and controls remain to be identified, and further research is warranted to evaluate in vitro-in vivo correlations and the ability of in vitro models to predict in vivo effects. The physicochemical and pharmacological properties of the drug(s) and the drug product, as well as dermal clearance and heat gradients may require careful consideration. PMID:26808472

  13. Combined magnetic resonance, fluorescence, and histology imaging strategy in a human breast tumor xenograft model

    PubMed Central

    Jiang, Lu; Greenwood, Tiffany R.; Amstalden van Hove, Erika R.; Chughtai, Kamila; Raman, Venu; Winnard, Paul T.; Heeren, Ron; Artemov, Dmitri; Glunde, Kristine

    2014-01-01

    Applications of molecular imaging in cancer and other diseases frequently require combining in vivo imaging modalities, such as magnetic resonance and optical imaging, with ex vivo optical, fluorescence, histology, and immunohistochemical (IHC) imaging, to investigate and relate molecular and biological processes to imaging parameters within the same region of interest. We have developed a multimodal image reconstruction and fusion framework that accurately combines in vivo magnetic resonance imaging (MRI) and magnetic resonance spectroscopic imaging (MRSI), ex vivo brightfield and fluorescence microscopic imaging, and ex vivo histology imaging. Ex vivo brightfield microscopic imaging was used as an intermediate modality to facilitate the ultimate link between ex vivo histology and in vivo MRI/MRSI. Tissue sectioning necessary for optical and histology imaging required generation of a three-dimensional (3D) reconstruction module for 2D ex vivo optical and histology imaging data. We developed an external fiducial marker based 3D reconstruction method, which was able to fuse optical brightfield and fluorescence with histology imaging data. Registration of 3D tumor shape was pursued to combine in vivo MRI/MRSI and ex vivo optical brightfield and fluorescence imaging data. This registration strategy was applied to in vivo MRI/MRSI, ex vivo optical brightfield/fluorescence, as well as histology imaging data sets obtained from human breast tumor models. 3D human breast tumor data sets were successfully reconstructed and fused with this platform. PMID:22945331

  14. Glioma survival prediction with the combined analysis of in vivo 11C-MET-PET, ex vivo and patient features by supervised machine learning.

    PubMed

    Papp, Laszlo; Poetsch, Nina; Grahovac, Marko; Schmidbauer, Victor; Woehrer, Adelheid; Preusser, Matthias; Mitterhauser, Markus; Kiesel, Barbara; Wadsak, Wolfgang; Beyer, Thomas; Hacker, Marcus; Traub-Weidinger, Tatjana

    2017-11-24

    Gliomas are the most common types of tumors in the brain. While the definite diagnosis is routinely made ex vivo by histopathologic and molecular examination, diagnostic work-up of patients with suspected glioma is mainly done by using magnetic resonance imaging (MRI). Nevertheless, L-S-methyl- 11 C-methionine ( 11 C-MET) Positron Emission Tomography (PET) holds a great potential in characterization of gliomas. The aim of this study was to establish machine learning (ML) driven survival models for glioma built on 11 C-MET-PET, ex vivo and patient characteristics. Methods: 70 patients with a treatment naïve glioma, who had a positive 11 C-MET-PET and histopathology-derived ex vivo feature extraction, such as World Health Organization (WHO) 2007 tumor grade, histology and isocitrate dehydrogenase (IDH1-R132H) mutation status were included. The 11 C-MET-positive primary tumors were delineated semi-automatically on PET images followed by the feature extraction of tumor-to-background ratio based general and higher-order textural features by applying five different binning approaches. In vivo and ex vivo features, as well as patient characteristics (age, weight, height, body-mass-index, Karnofsky-score) were merged to characterize the tumors. Machine learning approaches were utilized to identify relevant in vivo, ex vivo and patient features and their relative weights for 36 months survival prediction. The resulting feature weights were used to establish three predictive models per binning configuration based on a combination of: in vivo/ex vivo and clinical patient information (M36IEP), in vivo and patient-only information (M36IP), and in vivo only (M36I). In addition a binning-independent ex vivo and patient-only (M36EP) model was created. The established models were validated in a Monte Carlo (MC) cross-validation scheme. Results: Most prominent ML-selected and -weighted features were patient and ex vivo based followed by in vivo features. The highest area under the curve (AUC) values of our models as revealed by the MC cross-validation were: 0.9 (M36IEP), 0.87 (M36EP), 0.77 (M36IP) and 0.72 (M36I). Conclusion: Survival prediction of glioma patients based on amino acid PET using computer-supported predictive models based on in vivo, ex vivo and patient features is highly accurate. Copyright © 2017 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  15. Toxicokinetic and Dosimetry Modeling Tools for Exposure Reconstruction: US EPA's Rapid Exposure and Dosimetry (RED) Project

    EPA Science Inventory

    New technologies and in vitro testing approaches have been valuable additions to risk assessments that have historically relied solely on in vivo test results. Compared to in vivo methods, in vitro high throughput screening (HTS) assays are less expensive, faster and can provide ...

  16. Dissolution and dissolution/permeation experiments for predicting systemic exposure following oral administration of the BCS class II drug clarithromycin.

    PubMed

    Kristin, Forner; René, Holm; Boontida, Morakul; Buraphacheep, Junyaprasert Varaporn; Maximilian, Ackermann; Johanna, Mazur; Peter, Langguth

    2017-04-01

    In order to save time and resources in early drug development, in vitro methods that correctly predict the formulation effect on oral drug absorption are necessary. The aim of this study was to 1) evaluate various BCS class II drug formulations with in vitro methods and in vivo in order to 2) determine which in vitro method best correlates with the in vivo results. Clarithromycin served as model compound in formulations with different particle sizes and content of excipients. The performed in vitro experiments were dissolution and dissolution/permeation experiments across two types of membrane, Caco-2 cells and excised rat intestinal sheets. The in vivo study was performed in rats. The oral absorption was enhanced by downsizing drug particles and by increasing the excipient concentration. This correlated strongly with the flux across Caco-2 cells but not with the other in vitro experiments. The insufficient correlation with the dissolution experiments can be partly explained by excipient caused problems during the filtration step. The very poor correlation of the in vivo data with the flux across excised rat intestinal sheets might be due to an artificially enlarged mucus layer ex vivo. In conclusion, downsizing BCS class II drug particles and the addition of surfactants enhanced the in vivo absorption, which was best depicted by dissolution/permeation experiments across Caco-2 cells. This setup is proposed as best model to predict the in vivo formulation effect. Also, this is the first study to evaluate the impact of the nature of the permeation membrane in dissolution/permeation experiments. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Quantitative in vivo optical tomography of cancer progression & vasculature development in adult zebrafish

    PubMed Central

    Kumar, Sunil; Lockwood, Nicola; Ramel, Marie-Christine; Correia, Teresa; Ellis, Matthew; Alexandrov, Yuriy; Andrews, Natalie; Patel, Rachel; Bugeon, Laurence; Dallman, Margaret J.; Brandner, Sebastian; Arridge, Simon; Katan, Matilda; McGinty, James; Frankel, Paul; French, Paul M.W.

    2016-01-01

    We describe a novel approach to study tumour progression and vasculature development in vivo via global 3-D fluorescence imaging of live non-pigmented adult zebrafish utilising angularly multiplexed optical projection tomography with compressive sensing (CS-OPT). This “mesoscopic” imaging method bridges a gap between established ~μm resolution 3-D fluorescence microscopy techniques and ~mm-resolved whole body planar imaging and diffuse tomography. Implementing angular multiplexing with CS-OPT, we demonstrate the in vivo global imaging of an inducible fluorescently labelled genetic model of liver cancer in adult non-pigmented zebrafish that also present fluorescently labelled vasculature. In this disease model, addition of a chemical inducer (doxycycline) drives expression of eGFP tagged oncogenic K-RASV12 in the liver of immune competent animals. We show that our novel in vivo global imaging methodology enables non-invasive quantitative imaging of the development of tumour and vasculature throughout the progression of the disease, which we have validated against established methods of pathology including immunohistochemistry. We have also demonstrated its potential for longitudinal imaging through a study of vascular development in the same zebrafish from early embryo to adulthood. We believe that this instrument, together with its associated analysis and data management tools, constitute a new platform for in vivo cancer studies and drug discovery in zebrafish disease models. PMID:27259259

  18. An in vivo model for evaluating the response of pulp to various biomaterials.

    PubMed

    McClugage, S G; Holmstedt, J O; Malloy, R B

    1980-09-01

    An in vivo model has been designed to study the acute response of exposed or unexposed dental pulp to the topical application of various biomaterials. This model permits sequential microscopic observations of the microvascular system of dental pulp before and after application of pulp capping agents, cementing agents, or cavity liners. The use of this experimental model provides useful information related to the tolerability of dental pulp to various biomaterials used in dentistry. Furthermore, this model serves as a useful supplement to more traditional long term methods for evaluating the biocompatability of dental materials.

  19. Surgical model pig ex vivo for venous dissection teaching in medical schools.

    PubMed

    Tube, Milton Ignacio Carvalho; Spencer-Netto, Fernando Antonio Campelo; Oliveira, Anderson Igor Pereira de; Holanda, Arthur Cesário de; Barros, Bruno Leão Dos Santos; Rezende, Caio Cezar Gomes; Cavalcanti, João Pedro Guerra; Batista, Marília Apolinário; Campos, Josemberg Marins

    2017-02-01

    To investigate a method for development of surgical skills in medical students simulating venous dissection in surgical ex vivo pig model. Prospective, analytical, experimental, controlled study with four stages: selection, theoretical teaching, training and assessment. Sample of 312 students was divided into two groups: Group A - 2nd semester students; Group B - students of 8th semester. The groups were divided into five groups of 12 students, trained two hours per week in the semester. They set up four models to three students in each skill station assisted by a monitor. Teaching protocol emergency procedures training were applied to venous dissection, test goal-discursive and OSATS scale. The pre-test confirmed that the methodology has not been previously applied to the students. The averages obtained in the theoretical evaluation reached satisfactory parameters in both groups. The results of applying OSATS scale showed the best performance in group A compared to group B, however, both groups had satisfactory medium. The method was enough to raise a satisfactory level of skill both groups in venous dissection running on surgical swine ex vivo models.

  20. Integrative Approaches for Predicting in vivo Effects of Chemicals from their Structural Descriptors and the Results of Short-term Biological Assays

    PubMed Central

    Low, Yen S.; Sedykh, Alexander; Rusyn, Ivan; Tropsha, Alexander

    2017-01-01

    Cheminformatics approaches such as Quantitative Structure Activity Relationship (QSAR) modeling have been used traditionally for predicting chemical toxicity. In recent years, high throughput biological assays have been increasingly employed to elucidate mechanisms of chemical toxicity and predict toxic effects of chemicals in vivo. The data generated in such assays can be considered as biological descriptors of chemicals that can be combined with molecular descriptors and employed in QSAR modeling to improve the accuracy of toxicity prediction. In this review, we discuss several approaches for integrating chemical and biological data for predicting biological effects of chemicals in vivo and compare their performance across several data sets. We conclude that while no method consistently shows superior performance, the integrative approaches rank consistently among the best yet offer enriched interpretation of models over those built with either chemical or biological data alone. We discuss the outlook for such interdisciplinary methods and offer recommendations to further improve the accuracy and interpretability of computational models that predict chemical toxicity. PMID:24805064

  1. Developing Xenopus Laevis as a Model to Screen Drugs for Fragile X Syndrome

    DTIC Science & Technology

    2014-06-01

    demonstrated the capacity to rescue the decreased FMRP expression by gene delivery. We characterized an innate visually-guided avoidance behavior in tadpoles ... tadpole is a unique model system that allows easy access to the nervous system at early stages of development, is amenable to in vivo gene...established quantitative in vivo imaging methods to knockdown and assay synthesis of FMRP in Xenopus tadpole brains. We also established 2 behavioral

  2. A level A in vitro/in vivo correlation in fasted and fed states using different methods: applied to solid immediate release oral dosage form.

    PubMed

    Souliman, Sabah; Blanquet, Stéphanie; Beyssac, Eric; Cardot, Jean-Michel

    2006-01-01

    The first purpose of this study was to simulate the impact of food intake on drug release and absorption in vivo using a novel in vitro system which mimics the gastro-intestinal (GI) tract in man. The drug studied was acetaminophen in the form of immediate release (IR) tablets. The second purpose was to establish a level A in vitro/in vivo correlation that could predict the bioavailability of a drug instead of using difficult, time-consuming and expensive in vivo bioequivalence studies. The artificial digestive system was used to estimate the availability of acetaminophen IR tablets for absorption in fasted and fed states. The same study was performed in vivo under similar conditions. A comparison study was carried out between the classical and the novel methods to estimate the efficacy of the new in vitro system to simulate the influence of food on drug release and absorption in vivo. A level A in vitro/in vivo correlation was established with a correlation coefficient of 0.9128 and 0.9984 in the fasted and fed states, respectively. Compared to USP II method, the novel in vitro model demonstrated a high level of efficacy in mimicking the behaviour of acetaminophen IR tablets in vivo in fasted and fed states.

  3. Application of Computational and High-Throughput in vitro ...

    EPA Pesticide Factsheets

    Abstract: There are tens of thousands of man-made chemicals to which humans are exposed, but only a fraction of these have the extensive in vivo toxicity data used in most traditional risk assessments. This lack of data, coupled with concerns about testing costs and animal use, are driving the development of new methods for assessing the risk of toxicity. These methods include the use of in vitro high-throughput screening assays and computational models. This talk will review a variety of high-throughput, non-animal methods being used at the U.S. EPA to screen chemicals for a variety of toxicity endpoints, with a focus on their potential to be endocrine disruptors as part of the Endocrine Disruptor Screening Program (EDSP). These methods all start with the use of in vitro assays, e.g. for activity against the estrogen and androgen receptors (ER and AR) and targets in the steroidogenesis and thyroid signaling pathways. Because all individual assays are subject to a variety of noise processes and technology-specific assay artefacts, we have developed methods to create consensus predictions from multiple assays against the same target. The goal of these models is to both robustly predict in vivo activity, and also to provide quantitative estimates of uncertainty. This talk will describe these models, and how they are validated against both in vitro and in vivo reference chemicals. The U.S. EPA has deemed the in vitro ER model results to be of high enough accuracy t

  4. Application of computational and high-throughput in vitro ...

    EPA Pesticide Factsheets

    Abstract: There are tens of thousands of man-made chemicals to which humans are exposed, but only a fraction of these have the extensive in vivo toxicity data used in most traditional risk assessments. This lack of data, coupled with concerns about testing costs and animal use, are driving the development of new methods for assessing the risk of toxicity. These methods include the use of in vitro high-throughput screening assays and computational models. This talk will review a variety of high-throughput, non-animal methods being used at the U.S. EPA to screen chemicals for their potential to be endocrine disruptors as part of the Endocrine Disruptor Screening Program (EDSP). These methods all start with the use of in vitro assays, e.g. for activity against the estrogen and androgen receptors (ER and AR) and targets in the steroidogenesis and thyroid signaling pathways. Because all individual assays are subject to a variety of noise processes and technology-specific assay artefacts, we have developed methods to create consensus predictions from multiple assays against the same target. The goal of these models is to both robustly predict in vivo activity, and also to provide quantitative estimates of uncertainty. This talk will describe these models, and how they are validated against both in vitro and in vivo reference chemicals. The U.S. EPA has deemed the in vitro ER model results to be of high enough accuracy to be used as a substitute for the current EDSP Ti

  5. In Vivo Axial Loading of the Mouse Tibia

    PubMed Central

    Melville, Katherine M.; Robling, Alexander G.

    2015-01-01

    Summary Non-invasive methods to apply controlled, cyclic loads to the living skeleton are used as an anabolic agent to stimulate new bone formation in adults and enhance bone mass accrual in growing animals. These methods are also invaluable for understanding bone signaling pathways. Our focus here is on a particular loading model: in vivo axial compression of the mouse tibia. An advantage of loading the tibia is that changes are present in both the cancellous envelope of the proximal tibia and the cortical bone of the tibial diaphysis. To load the tibia of the mouse axially in vivo, a cyclic compressive load is applied up to five times a week to a single tibia per mouse for a duration lasting from 1 day to 6 weeks. With the contralateral limb as an internal control, the anabolic response of the skeleton to mechanical stimuli can be studied in a pairwise experimental design. Here, we describe the key parameters that must be considered before beginning an in vivo mouse tibial loading experiment, including methods for in vivo strain gauging of the tibial midshaft, and then we describe general methods for loading the mouse tibia for an experiment lasting multiple days. PMID:25331046

  6. Refined methods to evaluate the in vivo hemostatic function and viability of transfused human platelets in rabbit models.

    PubMed

    Watanabe, Naohide; Nogawa, Masayuki; Ishiguro, Mariko; Maruyama, Hitomi; Shiba, Masayuki; Satake, Masahiro; Eto, Koji; Handa, Makoto

    2017-08-01

    To bridge the gap between in vitro function and clinical efficacy of platelet (PLT) transfusion products, reliable in vivo PLT functional assays for hemostasis and survival in animal models are required. However, there are no standardized methods for assessing the in vivo quality of transfused human PLTs. Plasma-depleted human PLT concentrates (PCs; Day 3, Day 5, Day 7, Day 10, and damaged) were transfused into busulfan-induced rabbits with thrombocytopenia with prolonged bleeding times 1 day after treatment with ethyl palmitate (EP) to block their reticuloendothelial systems. The hemostatic effect of PC transfusion was evaluated by the ear fine vein bleeding time. For the in vivo survival assay, splenectomized EP-treated rabbits were transfused with human PCs, and viability of the human PLTs in the rabbits was determined by flow cytometry using human PLT-specific antibodies and Trucount tubes. The hemostatic effect of PCs was slightly reduced with increasing storage periods for early time points, but more dramatically reduced for later time points. PLT survival was similar after 3 and 7 days of storage, but PLTs stored for 10 days showed significantly poorer survival than those stored only 3 days. Our new and improved protocol for in vivo assessment of transfused PLTs is sufficiently sensitive to detect subtle changes in hemostatic function and viability of human PLTs transfused into rabbit models. This protocol could contribute to preclinical in vivo functional assessment and clinical quality assurance of emerging novel PLT products such as cultured cell-derived human PLTs. © 2017 AABB.

  7. Image-based modelling of skeletal muscle oxygenation

    PubMed Central

    Clough, G. F.

    2017-01-01

    The supply of oxygen in sufficient quantity is vital for the correct functioning of all organs in the human body, in particular for skeletal muscle during exercise. Disease is often associated with both an inhibition of the microvascular supply capability and is thought to relate to changes in the structure of blood vessel networks. Different methods exist to investigate the influence of the microvascular structure on tissue oxygenation, varying over a range of application areas, i.e. biological in vivo and in vitro experiments, imaging and mathematical modelling. Ideally, all of these methods should be combined within the same framework in order to fully understand the processes involved. This review discusses the mathematical models of skeletal muscle oxygenation currently available that are based upon images taken of the muscle microvasculature in vivo and ex vivo. Imaging systems suitable for capturing the blood vessel networks are discussed and respective contrasting methods presented. The review further informs the association between anatomical characteristics in health and disease. With this review we give the reader a tool to understand and establish the workflow of developing an image-based model of skeletal muscle oxygenation. Finally, we give an outlook for improvements needed for measurements and imaging techniques to adequately investigate the microvascular capability for oxygen exchange. PMID:28202595

  8. Testing an unusual in vivo vessel network model: a method to study angiogenesis in the colonial tunicate Botryllus schlosseri

    PubMed Central

    Gasparini, Fabio; Caicci, Federico; Rigon, Francesca; Zaniolo, Giovanna; Manni, Lucia

    2014-01-01

    Tunicates are the closest relatives to vertebrates and include the only chordate species able to reproduce both sexually and asexually. The colonial tunicate Botryllus schlosseri is embedded in a transparent extracellular matrix (the tunic) containing the colonial circulatory system (CCS). The latter is a network of vessels external to zooids, limited by a simple, flat epithelium that originated from the epidermis. The CCS propagates and regenerates by remodelling and extending the vessel network through the mechanism of sprouting, which typically characterises vertebrate angiogenesis. In exploiting the characteristics of B. schlosseri as a laboratory model, we present a new experimental and analysis method based on the ability to obtain genetically identical subclones representing paired samples for the appropriate quantitative outcome statistical analysis. The method, tested using human VEGF and EGF to induce angiogenesis, shows that the CCS provides a useful in vivo vessel network model for testing the effects of specific injected solutes on vessel dynamics. These results show the potentiality of B. schlosseri CCS as an effective complementary model for in vivo studies on angiogenesis and anticancer therapy. We discuss this potentiality, taking into consideration the origin, nature, and roles of the cellular and molecular agents involved in CCS growth. PMID:25248762

  9. Imaging of prostate cancer: a platform for 3D co-registration of in-vivo MRI ex-vivo MRI and pathology

    NASA Astrophysics Data System (ADS)

    Orczyk, Clément; Mikheev, Artem; Rosenkrantz, Andrew; Melamed, Jonathan; Taneja, Samir S.; Rusinek, Henry

    2012-02-01

    Objectives: Multi-parametric MRI is emerging as a promising method for prostate cancer diagnosis. prognosis and treatment planning. However, the localization of in-vivo detected lesions and pathologic sites of cancer remains a significant challenge. To overcome this limitation we have developed and tested a system for co-registration of in-vivo MRI, ex-vivo MRI and histology. Materials and Methods: Three men diagnosed with localized prostate cancer (ages 54-72, PSA levels 5.1-7.7 ng/ml) were prospectively enrolled in this study. All patients underwent 3T multi-parametric MRI that included T2W, DCEMRI, and DWI prior to robotic-assisted prostatectomy. Ex-vivo multi-parametric MRI was performed on fresh prostate specimen. Excised prostates were then sliced at regular intervals and photographed both before and after fixation. Slices were perpendicular to the main axis of the posterior capsule, i.e., along the direction of the rectal wall. Guided by the location of the urethra, 2D digital images were assembled into 3D models. Cancer foci, extra-capsular extensions and zonal margins were delineated by the pathologist and included in 3D histology data. A locally-developed software was applied to register in-vivo, ex-vivo and histology using an over-determined set of anatomical landmarks placed in anterior fibro-muscular stroma, central. transition and peripheral zones. The mean root square distance across corresponding control points was used to assess co-registration error. Results: Two specimens were pT3a and one pT2b (negative margin) at pathology. The software successfully fused invivo MRI. ex-vivo MRI fresh specimen and histology using appropriate (rigid and affine) transformation models with mean square error of 1.59 mm. Coregistration accuracy was confirmed by multi-modality viewing using operator-guided variable transparency. Conclusion: The method enables successful co-registration of pre-operative MRI, ex-vivo MRI and pathology and it provides initial evidence of feasibility of MRI-guided surgical planning.

  10. A technique for in vivo measurement of photoreceptor orientation in the chicken retina.

    PubMed

    Beresford, J A; Crewther, S G; Crewther, D P

    1999-01-01

    The aim of the current study was to develop a method for simultaneously assessing central and peripheral photoreceptor alignment in vivo in animal models. The stimulus apparatus consisted of nine light-emitting diodes (LED) positioned 7.5 degrees apart around an arc. The stimulus was viewed through a pinhole imaged into the entrance pupil of the eye using a telecentric lens system. Photodiodes placed over an array of the VERIS imaging system stimulated the electroretinogram. Data were obtained by positioning the pinhole at 0.25-mm intervals across the pupil and recording (Volk Optical, Mentor, OH, USA) at each location. Orientation assessed in normal chickens demonstrates that photoreceptors orientate towards a locus near the centre of the pupil and that there is a systematic change in peak location with eccentricity. This technique provides a valuable method for determining photoreceptor orientation properties in vivo and can be applied to animal models of pathology.

  11. Imaging molecular dynamics in vivo--from cell biology to animal models.

    PubMed

    Timpson, Paul; McGhee, Ewan J; Anderson, Kurt I

    2011-09-01

    Advances in fluorescence microscopy have enabled the study of membrane diffusion, cell adhesion and signal transduction at the molecular level in living cells grown in culture. By contrast, imaging in living organisms has primarily been restricted to the localization and dynamics of cells in tissues. Now, imaging of molecular dynamics is on the cusp of progressing from cell culture to living tissue. This transition has been driven by the understanding that the microenvironment critically determines many developmental and pathological processes. Here, we review recent progress in fluorescent protein imaging in vivo by drawing primarily on cancer-related studies in mice. We emphasize the need for techniques that can be easily combined with genetic models and complement fluorescent protein imaging by providing contextual information about the cellular environment. In this Commentary we will consider differences between in vitro and in vivo experimental design and argue for an approach to in vivo imaging that is built upon the use of intermediate systems, such as 3-D and explant culture models, which offer flexibility and control that is not always available in vivo. Collectively, these methods present a paradigm shift towards the molecular-level investigation of disease and therapy in animal models of disease.

  12. Digital One Disc One Compound Method for High Throughput Discovery of Prostate Cancer Targeting Ligands

    DTIC Science & Technology

    2016-12-01

    near-infrared imaging to evaluate in vivo the tumor targeting properties of the prostate cancer ligands on xenograft models, from which in vivo...2007). (13) Rosca, E.V., Gillies, R.J. & Caplan, M.R. Glioblastoma targeting via integrins is concentration dependent. Biotechnol Bioeng 104, 408

  13. Informatics approach using metabolic reactivity classifiers to link in vitro to in vivo data in application to the ToxCast Phase I dataset

    EPA Science Inventory

    Strategic combinations and tiered application of alternative testing methods to replace or minimize the use of animal models is attracting much attention. With the advancement of high throughput screening (HTS) assays and legacy databases providing in vivo testing results, suffic...

  14. Correlation Between Physicochemical Characteristics and Toxicological Properties of Nanomaterials

    DTIC Science & Technology

    2012-01-25

    gold, Mn, MWCNT , on the targeted surfaces. An in - vivo electrospray system was developed to disperse airborne CNTs and TiO2, QDs with various degrees...Finkelstein, JN, Elder A, Bentley K, Oberdörster G, and Pui DYH. A nanoparticle dispersion method for in vitro and in vivo nanotoxicity study...Pentland, AP, DeLouise, LA. (2008). In vivo skin penetration of quantum dot nanopartiles in the murine model: The effect of UVR. Nano Letters

  15. Ultra High-Resolution In vivo Computed Tomography Imaging of Mouse Cerebrovasculature Using a Long Circulating Blood Pool Contrast Agent

    PubMed Central

    Starosolski, Zbigniew; Villamizar, Carlos A.; Rendon, David; Paldino, Michael J.; Milewicz, Dianna M.; Ghaghada, Ketan B.; Annapragada, Ananth V.

    2015-01-01

    Abnormalities in the cerebrovascular system play a central role in many neurologic diseases. The on-going expansion of rodent models of human cerebrovascular diseases and the need to use these models to understand disease progression and treatment has amplified the need for reproducible non-invasive imaging methods for high-resolution visualization of the complete cerebral vasculature. In this study, we present methods for in vivo high-resolution (19 μm isotropic) computed tomography imaging of complete mouse brain vasculature. This technique enabled 3D visualization of large cerebrovascular networks, including the Circle of Willis. Blood vessels as small as 40 μm were clearly delineated. ACTA2 mutations in humans cause cerebrovascular defects, including abnormally straightened arteries and a moyamoya-like arteriopathy characterized by bilateral narrowing of the internal carotid artery and stenosis of many large arteries. In vivo imaging studies performed in a mouse model of Acta2 mutations demonstrated the utility of this method for studying vascular morphometric changes that are practically impossible to identify using current histological methods. Specifically, the technique demonstrated changes in the width of the Circle of Willis, straightening of cerebral arteries and arterial stenoses. We believe the use of imaging methods described here will contribute substantially to the study of rodent cerebrovasculature. PMID:25985192

  16. Generalized in vitro-in vivo relationship (IVIVR) model based on artificial neural networks

    PubMed Central

    Mendyk, Aleksander; Tuszyński, Paweł K; Polak, Sebastian; Jachowicz, Renata

    2013-01-01

    Background The aim of this study was to develop a generalized in vitro-in vivo relationship (IVIVR) model based on in vitro dissolution profiles together with quantitative and qualitative composition of dosage formulations as covariates. Such a model would be of substantial aid in the early stages of development of a pharmaceutical formulation, when no in vivo results are yet available and it is impossible to create a classical in vitro-in vivo correlation (IVIVC)/IVIVR. Methods Chemoinformatics software was used to compute the molecular descriptors of drug substances (ie, active pharmaceutical ingredients) and excipients. The data were collected from the literature. Artificial neural networks were used as the modeling tool. The training process was carried out using the 10-fold cross-validation technique. Results The database contained 93 formulations with 307 inputs initially, and was later limited to 28 in a course of sensitivity analysis. The four best models were introduced into the artificial neural network ensemble. Complete in vivo profiles were predicted accurately for 37.6% of the formulations. Conclusion It has been shown that artificial neural networks can be an effective predictive tool for constructing IVIVR in an integrated generalized model for various formulations. Because IVIVC/IVIVR is classically conducted for 2–4 formulations and with a single active pharmaceutical ingredient, the approach described here is unique in that it incorporates various active pharmaceutical ingredients and dosage forms into a single model. Thus, preliminary IVIVC/IVIVR can be available without in vivo data, which is impossible using current IVIVC/IVIVR procedures. PMID:23569360

  17. A radiopaque electrospun scaffold for engineering fibrous musculoskeletal tissues: Scaffold characterization and in vivo applications.

    PubMed

    Martin, John T; Milby, Andrew H; Ikuta, Kensuke; Poudel, Subash; Pfeifer, Christian G; Elliott, Dawn M; Smith, Harvey E; Mauck, Robert L

    2015-10-01

    Tissue engineering strategies have emerged in response to the growing prevalence of chronic musculoskeletal conditions, with many of these regenerative methods currently being evaluated in translational animal models. Engineered replacements for fibrous tissues such as the meniscus, annulus fibrosus, tendons, and ligaments are subjected to challenging physiologic loads, and are difficult to track in vivo using standard techniques. The diagnosis and treatment of musculoskeletal conditions depends heavily on radiographic assessment, and a number of currently available implants utilize radiopaque markers to facilitate in vivo imaging. In this study, we developed a nanofibrous scaffold in which individual fibers included radiopaque nanoparticles. Inclusion of radiopaque particles increased the tensile modulus of the scaffold and imparted radiation attenuation within the range of cortical bone. When scaffolds were seeded with bovine mesenchymal stem cells in vitro, there was no change in cell proliferation and no evidence of promiscuous conversion to an osteogenic phenotype. Scaffolds were implanted ex vivo in a model of a meniscal tear in a bovine joint and in vivo in a model of total disc replacement in the rat coccygeal spine (tail), and were visualized via fluoroscopy and microcomputed tomography. In the disc replacement model, histological analysis at 4 weeks showed that the scaffold was biocompatible and supported the deposition of fibrous tissue in vivo. Nanofibrous scaffolds that include radiopaque nanoparticles provide a biocompatible template with sufficient radiopacity for in vivo visualization in both small and large animal models. This radiopacity may facilitate image-guided implantation and non-invasive long-term evaluation of scaffold location and performance. The healing capacity of fibrous musculoskeletal tissues is limited, and injury or degeneration of these tissues compromises the standard of living of millions in the US. Tissue engineering repair strategies for the intervertebral disc, meniscus, tendon and ligament have progressed from in vitro to in vivo evaluation using a variety of animal models, and the clinical application of these technologies is imminent. The composition of most scaffold materials however does not allow for visualization by methods available to clinicians (e.g., radiography), and thus it is not possible to assess their performance in situ. In this work, we describe a radiopaque nanofibrous scaffold that can be visualized radiographically in both small and large animal models and serve as a framework for the development of an engineered fibrous tissue. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  18. From impedance theory to needle electrode guidance in tissue

    NASA Astrophysics Data System (ADS)

    Kalvøy, Håvard; Høyum, Per; Grimnes, Sverre; Martinsen, Ørjan G.

    2010-04-01

    Fast access to blood vessels or other tissues/organs can be crucial in clinical or acute medical treatment. We have developed a method for needle guidance for use in different types of applications. The feasibility of an automatic application for fast access to blood vessels during acute cardiac arrest, based on this method, has been evaluated. Suited electrode setups were found by development of needle electrode models used in simulation and sensitivity analyses. In vitro measurements were done both to determine the fundamental properties of the electrodes for use in the models and to confirm the simulation results. Development of algorithms for tissue characterization and differentiation was based on in vivo impedance measurement in porcine models and confirmed in human tissue in vivo. Feasibility was proven by application prototyping and impedance data presented as invasive Electrical Impedance Tomography (iEIT). Our conclusion is that this method can be utilized in a wide range of clinical applications.

  19. Assessment of a new hub design and the semiquantitative catheter culture method using an in vivo experimental model of catheter sepsis.

    PubMed Central

    Segura, M; Alía, C; Valverde, J; Franch, G; Torres Rodríguez, J M; Sitges-Serra, A

    1990-01-01

    An in vivo model of hub-related catheter sepsis in rabbits is reported. The model was used to investigate the protection offered by a new hub design against external contamination by Pseudomonas aeruginosa or Staphylococcus epidermidis and to reassess the diagnostic value of the semiquantitative culture method in bacteremia of endoluminal origin. Contamination of conventional Luer-Lock connectors was followed by clinical sepsis, positive catheter segment cultures, or both, whereas contamination of the new hub was followed by complete protection. Clinical and bacteriological discrepancies observed between contamination with P. aeruginosa and S. epidermidis suggest that the virulence of microorganisms may account for differences in the natural history of hub-originated catheter sepsis. The semiquantitative extraluminal method for catheter culture yielded less than 15 CFU in three animals with proven bacteremia and should not be used as the "gold standard" to define catheter-related bacteremia. PMID:2254430

  20. Comparison of two different in vivo models and an in vitro model for caloric determination of four novel fiber ingredients.

    PubMed

    Cervantes-Pahm, Sarah; Knapp, Brenda K; Kim, Beob G; Liu, Yanhong; Parsons, Carl M; Fahey, George C; Stein, Hans H

    2013-12-18

    The objective of this study was to compare two in vivo methods using pigs and roosters and an in vitro method for determining the caloric value of four fiber sources [i.e., two resistant starches (RS 60 and RS 75), soluble corn fiber (SCF 70), and pullulan]. Metabolizable energy (ME) in pigs and true metabolizable energy (TMEn) in roosters were determined by using 72 barrows and 24 roosters, respectively. A two-step in vitro procedure was used to quantify monosaccharides released. Results of the two in vivo experiments corresponded well with RS 75 having the least caloric value (7.55 MJ/kg in pigs; 6.19 MJ/kg in roosters) and pullulan having the greatest caloric value (12.21 MJ/kg in pigs; 13.94 MJ/kg in roosters). The caloric values for all the fiber ingredients were less (P < 0.05) than in MD both in pigs and in roosters. Despite some limitations, results of the in vitro procedure corresponded well with the in vivo experiments where the concentration of glucose hydrolyzed from RS 60, RS 75, and SCF 70, but not pullulan, was less (P < 0.05) than the concentration of glucose hydrolyzed from MD. However, the greatest accuracy was obtained in the in vivo experiments.

  1. Dental pulp stem cells for in vivo bone regeneration: a systematic review of literature.

    PubMed

    Morad, Golnaz; Kheiri, Lida; Khojasteh, Arash

    2013-12-01

    This review of literature was aimed to assess in vivo experiments which have evaluated the efficacy of dental pulp stem cells (DPSCs) for bone regeneration. An electronic search of English-language papers was conducted on PubMed database. Studies that assessed the use of DPSCs in bone regeneration in vivo were included and experiments evaluating regeneration of hard tissues other than bone were excluded. The retrieved articles were thoroughly reviewed according to the source of stem cell, cell carrier, the in vivo experimental model, defect type, method of evaluating bone regeneration, and the obtained results. Further assessment of the results was conducted by classifying the studies based on the defect type. Seventeen papers formed the basis of this systematic review. Sixteen out of 17 experiments were performed on animal models with mouse and rat being the most frequently used animal models. Seven out of 17 animal studies, contained subcutaneous pockets on back of the animal for stem cell implantation. In only one study hard tissue formation was not observed. Other types of defects used in the retrieved studies, included cranial defects and mandibular bone defects, in all of which bone formation was reported. When applied in actual bone defects, DPSCs were capable of regenerating bone. Nevertheless, a precise conclusion regarding the efficiency of DPSCs for bone regeneration is yet to be made, considering the limited number of the in vivo experiments and the heterogeneity within their methods. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Reconstructing in-vivo reflectance spectrum of pigmented skin lesion by Monte Carlo simulation

    NASA Astrophysics Data System (ADS)

    Wang, Shuang; He, Qingli; Zhao, Jianhua; Lui, Harvey; Zeng, Haishan

    2012-03-01

    In dermatology applications, diffuse reflectance spectroscopy has been extensively investigated as a promising tool for the noninvasive method to distinguish melanoma from benign pigmented skin lesion (nevus), which is concentrated with the skin chromophores like melanin and hemoglobin. We carried out a theoretical study to examine melanin distribution in human skin tissue and establish a practical optical model for further pigmented skin investigation. The theoretical simulation was using junctional nevus as an example. A multiple layer skin optical model was developed on established anatomy structures of skin, the published optical parameters of different skin layers, blood and melanin. Monte Carlo simulation was used to model the interaction between excitation light and skin tissue and rebuild the diffuse reflectance process from skin tissue. A testified methodology was adopted to determine melanin contents in human skin based on in vivo diffuse reflectance spectra. The rebuild diffuse reflectance spectra were investigated by adding melanin into different layers of the theoretical model. One of in vivo reflectance spectra from Junctional nevi and their surrounding normal skin was studied by compare the ratio between nevus and normal skin tissue in both the experimental and simulated diffuse reflectance spectra. The simulation result showed a good agreement with our clinical measurements, which indicated that our research method, including the spectral ratio method, skin optical model and modifying the melanin content in the model, could be applied in further theoretical simulation of pigmented skin lesions.

  3. Steps for the autologous ex vivo perfused porcine liver-kidney experiment.

    PubMed

    Chung, Wen Yuan; Eltweri, Amar M; Isherwood, John; Haqq, Jonathan; Ong, Seok Ling; Gravante, Gianpiero; Lloyd, David M; Metcalfe, Matthew S; Dennison, Ashley R

    2013-12-18

    The use of ex vivo perfused models can mimic the physiological conditions of the liver for short periods, but to maintain normal homeostasis for an extended perfusion period is challenging. We have added the kidney to our previous ex vivo perfused liver experiment model to reproduce a more accurate physiological state for prolonged experiments without using live animals. Five intact livers and kidneys were retrieved post-mortem from sacrificed pigs on different days and perfused for a minimum of 6 hr. Hourly arterial blood gases were obtained to analyze pH, lactate, glucose and renal parameters. The primary endpoint was to investigate the effect of adding one kidney to the model on the acid base balance, glucose, and electrolyte levels. The result of this liver-kidney experiment was compared to the results of five previous liver only perfusion models. In summary, with the addition of one kidney to the ex vivo liver circuit, hyperglycemia and metabolic acidosis were improved. In addition this model reproduces the physiological and metabolic responses of the liver sufficiently accurately to obviate the need for the use of live animals. The ex vivo liver-kidney perfusion model can be used as an alternative method in organ specific studies. It provides a disconnection from numerous systemic influences and allows specific and accurate adjustments of arterial and venous pressures and flow.

  4. Using ToxCast in vitro Assays in the Hierarchical Quantitative Structure-Activity Relationship (QSAR) Modeling for Predicting in vivo Toxicity of Chemicals

    EPA Science Inventory

    The goal of chemical toxicology research is utilizing short term bioassays and/or robust computational methods to predict in vivo toxicity endpoints for chemicals. The ToxCast program established at the US Environmental Protection Agency (EPA) is addressing this goal by using ca....

  5. Species Extrapolation of Life-Stage Physiologically-Based Pharmacokinetic (PBPK) Models to Investigate the Developmental Toxicology of Ethanol Using In vitro to In vivo (IVIVE) Methods

    EPA Science Inventory

    To provide useful alternatives to in vivo animal studies, in vitro assays for dose-response assessments of xenobiotic chemicals must use concentrations in media and target tissues that are within biologically-plausible limits. Determining these concentrations is a complex matter,...

  6. In vitro dissolution method fitted to in vivo absorption profile of rivaroxaban immediate-release tablets applying in silico data.

    PubMed

    Wingert, Nathalie R; Dos Santos, Natália O; Campanharo, Sarah C; Simon, Elisa S; Volpato, Nadia M; Steppe, Martin

    2018-05-01

    This study aimed to develop and validate an in vitro dissolution method based on in silico-in vivo data to determine whether an in vitro-in vivo relationship could be established for rivaroxaban in immediate-release tablets. Oral drugs with high permeability but poorly soluble in aqueous media, such as the anticoagulant rivaroxaban, have a major potential to reach a high level of in vitro-in vivo relationship. Currently, there is no study on scientific literature approaching the development of RIV dissolution profile based on its in vivo performance. Drug plasma concentration values were modeled using computer simulation with adjustment of pharmacokinetic properties. Those values were converted into drug fractions absorbed by the Wagner-Nelson deconvolution approach. Gradual and continuous dissolution of RIV tablets was obtained with a 30 rpm basket on 50 mM sodium acetate +0.2% SDS, pH 6.5 medium. Dissolution was conducted for up to 180 min. The fraction absorbed was plotted against the drug fraction dissolved, and a linear point-to-point regression (R 2  = 0.9961) obtained. The in vitro dissolution method designed promoted a more convenient dissolution profile of RIV tablets, whereas it suggests a better relationship with in vivo performance.

  7. Biomaterials with persistent growth factor gradients in vivo accelerate vascularized tissue formation.

    PubMed

    Akar, Banu; Jiang, Bin; Somo, Sami I; Appel, Alyssa A; Larson, Jeffery C; Tichauer, Kenneth M; Brey, Eric M

    2015-12-01

    Gradients of soluble factors play an important role in many biological processes, including blood vessel assembly. Gradients can be studied in detail in vitro, but methods that enable the study of spatially distributed soluble factors and multi-cellular processes in vivo are limited. Here, we report on a method for the generation of persistent in vivo gradients of growth factors in a three-dimensional (3D) biomaterial system. Fibrin loaded porous poly (ethylene glycol) (PEG) scaffolds were generated using a particulate leaching method. Platelet derived growth factor BB (PDGF-BB) was encapsulated into poly (lactic-co-glycolic acid) (PLGA) microspheres which were placed distal to the tissue-material interface. PLGA provides sustained release of PDGF-BB and its diffusion through the porous structure results in gradient formation. Gradients within the scaffold were confirmed in vivo using near-infrared fluorescence imaging and gradients were present for more than 3 weeks. The diffusion of PDGF-BB was modeled and verified with in vivo imaging findings. The depth of tissue invasion and density of blood vessels formed in response to the biomaterial increased with magnitude of the gradient. This biomaterial system allows for generation of sustained growth factor gradients for the study of tissue response to gradients in vivo. Published by Elsevier Ltd.

  8. Quantification of fibronectin as a method to assess ex vivo extracellular matrix remodeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bager, C.L., E-mail: cba@nordicbioscience.com; Technical University of Denmark; Gudmann, N.

    Altered architecture, composition and quality of the extracellular matrix (ECM) are pathological hallmarks of several inflammatory and fibro-proliferative pathological processes such as osteoarthritis (OA), rheumatoid arthritis (RA), fibrosis and cancer. One of the most important components of the ECM is fibronectin. Fibronectin serves as an adhesion molecule anchoring cells to the underlying basement membrane through direct interaction with integrin receptors. Fibronectin hereby modulates the properties of the ECM and affects cellular processes. Quantification of fibronectin remodeling could therefore be used to assess the changes in the ECM that occur during progression of fibro-proliferative pathologies. Ex vivo models are becoming state-of-the-art toolsmore » to study ECM remodeling as the cellular composition and the organization of the ECM are preserved. Ex vivo models may therefore be a valuable tool to study the ECM remodeling that occurs during progression of fibro-proliferative pathologies. The aim of this study was to quantify fibronectin remodeling in ex vivo models of cartilage and cancer. A competitive The enzyme-linked immunosorbent assay (ELISA) against the C-terminus of fibronectin was developed (FBN-C). The assay was evaluated in relation to specificity, technical performance and as a marker for quantification of fibronectin in cartilage and cancer ex vivo models. The ELISA was specific and technically stable. Cleavage of tumor tissue with MMP-2 released significantly higher levels of FBN-C compared to tissue with buffer only and western blot analysis revealed that FBN-C recognizes both full length and degraded fibronectin. When ex vivo cartilage cultures were stimulated with the anabolic factor TGFβ and catabolic factors TNF-α and OSM, significantly higher levels of FBN-C were found in the conditioned media. Lastly, FBN-C was released from a cancer ex vivo model. In conclusion, we were able to quantify fibronectin remodeling in ex vivo models of cartilage and cancer. Quantification of fibronectin remodeling could be a valuable tool to understand ECM remodeling in ex vivo models of fibro-proliferative pathologies.« less

  9. Rank estimation and the multivariate analysis of in vivo fast-scan cyclic voltammetric data

    PubMed Central

    Keithley, Richard B.; Carelli, Regina M.; Wightman, R. Mark

    2010-01-01

    Principal component regression has been used in the past to separate current contributions from different neuromodulators measured with in vivo fast-scan cyclic voltammetry. Traditionally, a percent cumulative variance approach has been used to determine the rank of the training set voltammetric matrix during model development, however this approach suffers from several disadvantages including the use of arbitrary percentages and the requirement of extreme precision of training sets. Here we propose that Malinowski’s F-test, a method based on a statistical analysis of the variance contained within the training set, can be used to improve factor selection for the analysis of in vivo fast-scan cyclic voltammetric data. These two methods of rank estimation were compared at all steps in the calibration protocol including the number of principal components retained, overall noise levels, model validation as determined using a residual analysis procedure, and predicted concentration information. By analyzing 119 training sets from two different laboratories amassed over several years, we were able to gain insight into the heterogeneity of in vivo fast-scan cyclic voltammetric data and study how differences in factor selection propagate throughout the entire principal component regression analysis procedure. Visualizing cyclic voltammetric representations of the data contained in the retained and discarded principal components showed that using Malinowski’s F-test for rank estimation of in vivo training sets allowed for noise to be more accurately removed. Malinowski’s F-test also improved the robustness of our criterion for judging multivariate model validity, even though signal-to-noise ratios of the data varied. In addition, pH change was the majority noise carrier of in vivo training sets while dopamine prediction was more sensitive to noise. PMID:20527815

  10. Prediction of in vivo neutral detergent fiber digestibility and digestion rate of potentially digestible neutral detergent fiber: comparison of models.

    PubMed

    Huhtanen, P; Seppälä, A; Ahvenjärvi, S; Rinne, M

    2008-10-01

    Eleven 1-pool, seven 2-pool, and three 3-pool models were compared in fitting gas production data and predicting in vivo NDF digestibility and effective first-order digestion rate of potentially digestible NDF (pdNDF). Isolated NDF from 15 grass silages harvested at different stages of maturity was incubated in triplicate in rumen fluid-buffer solution for 72 h to estimate the digestion kinetics from cumulative gas production profiles. In vivo digestibility was estimated by the total fecal collection method in sheep fed at a maintenance level of feeding. The concentration of pdNDF was estimated by a 12-d in situ incubation. The parameter values from gas production profiles and pdNDF were used in a 2-compartment rumen model to predict pdNDF digestibility using 50 h of rumen residence time distributed in a ratio of 0.4:0.6 between the non-escapable and escapable pools. The effective first-order digestion rate was computed both from observed in vivo and model-predicted pdNDF digestibility assuming the passage kinetic model described above. There were marked differences between the models in fitting the gas production data. The fit improved with increasing number of pools, suggesting that silage pdNDF is not a homogenous substrate. Generally, the models predicted in vivo NDF digestibility and digestion rate accurately. However, a good fit of gas production data was not necessarily translated into improved predictions of the in vivo data. The models overestimating the asymptotic gas volumes tended to underestimate the in vivo digestibility. Investigating the time-related residuals during the later phases of fermentation is important when the data are used to estimate the first-order digestion rate of pdNDF. Relatively simple models such as the France model or even a single exponential model with discrete lag period satisfied the minimum criteria for a good model. Further, the comparison of feedstuffs on the basis of parameter values is more unequivocal than in the case of multiple-pool models.

  11. SU-F-T-229: A Novel Method for EPID-Based In-Vivo Exit Dose Verification for Intensity Modulated Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Z; Wang, J; Peng, J

    Purpose: Electronic portal imaging device (EPID) can be used to acquire a two-dimensional exit dose distribution during treatment delivery, thus allowing the in-vivo verification of the dose delivery through a comparison of measured portal images to predicted portal dose images (PDI). The aim of this study was to present a novel method to easily and accurately predict PDI, and to establish an EPID-based in-vivo dose verification method during IMRT treatments. Methods: We developed a model to determine the predicted portal dose at the same plane of the EPID detector location. The Varian EPID (aS1000) positions at 150cm source-to-detector-distance (SDD), andmore » can be used to acquire in-vivo exit dose using Portal Dosimetry (PD) function. Our model was generated to make an equivalent water thickness represent the buildup plate of EPID. The exit dose at extend SDD plane with patient CT data in the beam can be calculated as the predicted PDI in the treatment planning system (TPS). After that, the PDI was converted to the fluence at SDD of 150cm using the inverse square law coded in MATLAB. Five head-and-neck and prostate IMRT patient plans contain 32 fields were investigated to evaluate the feasibility of this new method. The measured EPID image was compared with PDI using the gamma analysis. Results: The average results for cumulative dose comparison were 81.9% and 91.6% for 3%, 3mm and 4%, 4mm gamma criteria, respectively. Results indicate that the patient transit dosimetry predicted algorithm compares well with EPID measured PD doses for test situations. Conclusion: Our new method can be used as an easy and feasible tool for online EPID-based in-vivo dose delivery verification for IMRT treatments. It can be implemented for fast detecting those obvious treatment delivery errors for individual field and patient quality assurance.« less

  12. Utilization of the k-space Computational Method to Design an Intracavitary Transrectal Ultrasound Phased Array Applicator for Hyperthermia Treatment of Prostate Cancer

    NASA Astrophysics Data System (ADS)

    Al-Bataineh, Osama M.; Collins, Christopher M.; Sparrow, Victor W.; Keolian, Robert M.; Smith, Nadine Barrie

    2006-05-01

    This research utilizes the k-space computational method to design an intracavitary probe for hyperthermia treatment of prostate cancer. A three-dimensional (3D) photographical prostate model, utilizing imaging data from the Visible Human Project®, was the basis for inhomogeneous acoustical model development. The acoustical model accounted for sound speed, density, and absorption variations. The k-space computational method was used to simulate ultrasound wave propagation of the designed phased array through the acoustical model. To insure the uniformity and spread of the pressure in the length of the array, and the steering and focusing capability in the width of the array, the equal-sized elements of the phased array were 1 × 14 mm. The anatomical measurements of the prostate were used to predict the final phased array specifications (4 × 20 planar array, 1.2 MHz, element size = 1 × 14 mm, array size = 56 × 20 mm). Good agreement between the exposimetry and the k-space results was achieved. As an example, the -3 dB distances of the focal volume were differing by 9.1% in the propagation direction for k-space prostate simulation and exposimetry results. Temperature simulations indicated that the rectal wall temperature was elevated less than 2°C during hyperthermia treatment. Steering and focusing ability of the designed probe, in both azimuth and propagation directions, were found to span the entire prostate volume with minimal grating lobes (-10 dB reduction from the main lobe) and least heat damage to the rectal wall. Evaluations of the probe included ex vivo and in vivo controlled experiments to deliver the required thermal dose to the targeted tissue. With a desired temperature plateau of 43.0°C, the MRI temperature results at the steady state were 42.9 ± 0.38°C and 43.1 ± 0.80°C for ex vivo and in vivo experiments, respectively. Unlike conventional computational methods, the k-space method provides a powerful tool to predict pressure wavefield and temperature rise in sophisticated, large scale, 3D, inhomogeneous and coarse grid models.

  13. Real-time assessment of corneal endothelial cell damage following graft preparation and donor insertion for DMEK

    PubMed Central

    Bhogal, Maninder; Lwin, Chan N.; Seah, Xin-Yi; Murugan, Elavazhagan; Adnan, Khadijah; Lin, Shu-Jun; Mehta, Jodhbir S.

    2017-01-01

    Purpose To establish a method for assessing graft viability, in-vivo, following corneal transplantation. Methods Optimization of calcein AM fluorescence and toxicity assessment was performed in cultured human corneal endothelial cells and ex-vivo corneal tissue. Descemet membrane endothelial keratoplasty grafts were incubated with calcein AM and imaged pre and post preparation, and in-situ after insertion and unfolding in a pig eye model. Global, macroscopic images of the entire graft and individual cell resolution could be attained by altering the magnification of a clinical confocal scanning laser microscope. Patterns of cell loss observed in situ were compared to those seen using standard ex-vivo techniques. Results Calcein AM showed a positive dose-fluorescence relationship. A dose of 2.67μmol was sufficient to allow clear discrimination between viable and non-viable areas (sensitivity of 96.6% with a specificity of 96.1%) and was not toxic to cultured endothelial cells or ex-vivo corneal tissue. Patterns of cell loss seen in-situ closely matched those seen on ex-vivo assessment with fluorescence viability imaging, trypan blue/alizarin red staining or scanning electron microscopy. Iatrogenic graft damage from preparation and insertion varied between 7–35% and incarceration of the graft tissue within surgical wounds was identified as a significant cause of endothelial damage. Conclusions In-situ graft viability assessment using clinical imaging devices provides comparable information to ex-vivo methods. This method shows high sensitivity and specificity, is non-toxic and can be used to evaluate immediate cell viability in new grafting techniques in-vivo. PMID:28977017

  14. In vivo distribution of spinal intervertebral stiffness based on clinical flexibility tests.

    PubMed

    Lafon, Yoann; Lafage, Virginie; Steib, Jean-Paul; Dubousset, Jean; Skalli, Wafa

    2010-01-15

    A numerical study was conducted to identify the intervertebral stiffness of scoliotic spines from spinal flexibility tests. To study the intervertebral 3-dimensional (3D) stiffness distribution along scoliotic spine. Few methods have been reported in literature to quantify the in vivo 3D intervertebral stiffness of the scoliotic spine. Based on the simulation of flexibility tests, these methods were operator-dependent and could yield to clinically irrelevant stiffnesses. This study included 30 patients surgically treated for severe idiopathic scoliosis. A previously validated trunk model, with patient-specific geometry, was used to simulate bending tests according to the in vivo displacements of T1 and L5 measured from bending test radiographs. Differences between in vivo and virtual spinal behaviors during bending tests (left and right) were computed in terms of vertebral rotations and translation. An automated method, driven by a priori knowledge, identified intervertebral stiffnesses in order to reproduce the in vivo spinal behavior. Because of the identification of intervertebral stiffnesses, differences between in vivo and virtual spinal displacements were drastically reduced (95% of the differences less than +/-3 mm for vertebral translation). Intervertebral stiffness distribution after identification was analyzed. On convex side test, the intervertebral stiffness of the compensatory curves increased in most cases, whereas the major curve became more flexible. Stiffness singularities were found in junctional zones: these specific levels were predominantly flexible, both in torsion and in lateral bending. The identification of in vivo intervertebral stiffness may improve our understanding of scoliotic spine and the relevance of patient-specific methods for surgical planning.

  15. In vivo imaging of protease activity by Probody therapeutic activation

    PubMed Central

    Wong, Kenneth R.; Menendez, Elizabeth; Craik, Charles S.; Kavanaugh, W. Michael; Vasiljeva, Olga

    2017-01-01

    Probody™ therapeutics are recombinant, proteolytically-activated antibody prodrugs, engineered to remain inert until activated locally by tumor-associated proteases. Probody therapeutics exploit the fundamental dysregulation of extracellular protease activity that exists in tumors relative to healthy tissue. Leveraging the ability of a Probody therapeutic to bind its target at the site of disease after proteolytic cleavage, we developed a novel method for profiling protease activity in living animals. Using NIR optical imaging, we demonstrated that a non-labeled anti-EGFR Probody therapeutic can become activated and compete for binding to tumor cells in vivo with a labeled anti-EGFR monoclonal antibody. Furthermore, by inhibiting matriptase activity in vivo with a blocking-matriptase antibody, we show that the ability of the Probody therapeutic to bind EGFR in vivo was dependent on protease activity. These results demonstrate that in vivo imaging of Probody therapeutic activation can be used for screening and characterization of protease activity in living animals, and provide a method that avoids some of the limitations of prior methods. This approach can improve our understanding of the activity of proteases in disease models and help to develop efficient strategies for cancer diagnosis and treatment. PMID:26546838

  16. Quantitative in vivo receptor binding. I. Theory and application to the muscarinic cholinergic receptor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frey, K.A.; Ehrenkaufer, R.L.; Beaucage, S.

    1985-02-01

    A novel approach to in vivo receptor binding experiments is presented which allows direct quantitation of binding site densities. The method is based on an equilibrium model of tracer uptake and is designed to produce a static distribution proportional to receptor density and to minimize possible confounding influences of regional blood flow, blood-brain barrier permeability, and nonspecific binding. This technique was applied to the measurement of regional muscarinic cholinergic receptor densities in rat brain using (/sup 3/H)scopolamine. Specific in vivo binding of scopolamine demonstrated saturability, a pharmacologic profile, and regional densities which are consistent with interaction of the tracer withmore » the muscarinic receptor. Estimates of receptor density obtained with the in vivo method and in vitro measurements in homogenates were highly correlated. Furthermore, reduction in striatal muscarinic receptors following ibotenic acid lesions resulted in a significant decrease in tracer uptake in vivo, indicating that the correlation between scopolamine distribution and receptor density may be used to demonstrate pathologic conditions. We propose that the general method presented here is directly applicable to investigation of high affinity binding sites for a variety of radioligands.« less

  17. Smoothness of In vivo Spectral Baseline Determined by Mean Squared Error

    PubMed Central

    Zhang, Yan; Shen, Jun

    2013-01-01

    Purpose A nonparametric smooth line is usually added to spectral model to account for background signals in vivo magnetic resonance spectroscopy (MRS). The assumed smoothness of the baseline significantly influences quantitative spectral fitting. In this paper, a method is proposed to minimize baseline influences on estimated spectral parameters. Methods In this paper, the non-parametric baseline function with a given smoothness was treated as a function of spectral parameters. Its uncertainty was measured by root-mean-squared error (RMSE). The proposed method was demonstrated with a simulated spectrum and in vivo spectra of both short echo time (TE) and averaged echo times. The estimated in vivo baselines were compared with the metabolite-nulled spectra, and the LCModel-estimated baselines. The accuracies of estimated baseline and metabolite concentrations were further verified by cross-validation. Results An optimal smoothness condition was found that led to the minimal baseline RMSE. In this condition, the best fit was balanced against minimal baseline influences on metabolite concentration estimates. Conclusion Baseline RMSE can be used to indicate estimated baseline uncertainties and serve as the criterion for determining the baseline smoothness of in vivo MRS. PMID:24259436

  18. Elastic scattering spectroscopy for detection of cancer risk in Barrett's esophagus: experimental and clinical validation of error removal by orthogonal subtraction for increasing accuracy

    NASA Astrophysics Data System (ADS)

    Zhu, Ying; Fearn, Tom; MacKenzie, Gary; Clark, Ben; Dunn, Jason M.; Bigio, Irving J.; Bown, Stephen G.; Lovat, Laurence B.

    2009-07-01

    Elastic scattering spectroscopy (ESS) may be used to detect high-grade dysplasia (HGD) or cancer in Barrett's esophagus (BE). When spectra are measured in vivo by a hand-held optical probe, variability among replicated spectra from the same site can hinder the development of a diagnostic model for cancer risk. An experiment was carried out on excised tissue to investigate how two potential sources of this variability, pressure and angle, influence spectral variability, and the results were compared with the variations observed in spectra collected in vivo from patients with Barrett's esophagus. A statistical method called error removal by orthogonal subtraction (EROS) was applied to model and remove this measurement variability, which accounted for 96.6% of the variation in the spectra, from the in vivo data. Its removal allowed the construction of a diagnostic model with specificity improved from 67% to 82% (with sensitivity fixed at 90%). The improvement was maintained in predictions on an independent in vivo data set. EROS works well as an effective pretreatment for Barrett's in vivo data by identifying measurement variability and ameliorating its effect. The procedure reduces the complexity and increases the accuracy and interpretability of the model for classification and detection of cancer risk in Barrett's esophagus.

  19. AlgiMatrix™-Based 3D Cell Culture System as an In Vitro Tumor Model: An Important Tool in Cancer Research.

    PubMed

    Godugu, Chandraiah; Singh, Mandip

    2016-01-01

    Routinely used two-dimensional cell culture-based models often fail while translating the observations into in vivo models. This setback is more common in cancer research, due to several reasons. The extracellular matrix and cell-to-cell interactions are not present in two-dimensional (2D) cell culture models. Diffusion of drug molecules into cancer cells is hindered by barriers of extracellular components in in vivo conditions, these barriers are absent in 2D cell culture models. To better mimic or simulate the in vivo conditions present in tumors, the current study used the alginate based three-dimensional cell culture (AlgiMatrix™) model, which resembles close to the in vivo tumor models. The current study explains the detailed protocols involved in AlgiMatrix™ based in vitro non-small-cell lung cancer (NSCLC) models. The suitability of this model was studied by evaluating, cytotoxicity, apoptosis, and penetration of nanoparticles into the in vitro tumor spheroids. This study also demonstrated the effect of EphA2 receptor targeted docetaxel-loaded nanoparticles on MDA-MB-468 TNBC cell lines. The methods section is subdivided into three subsections such as (1) preparation of AlgiMatrix™-based 3D in vitro tumor models and cytotoxicity assays, (2) free drug and nanoparticle uptake into spheroid studies, and (3) western blot, IHC, and RT-PCR studies.

  20. A novel in vivo model of puncture-induced iris neovascularization

    PubMed Central

    Aronsson, Monica; Kvanta, Anders

    2017-01-01

    Purpose To assess iris neovascularization by uveal puncture of the mouse eye and determine the role of angiogenic factors during iris neovascularization. Methods Uveal punctures were performed on BalbC mouse eyes to induce iris angiogenesis. VEGF-blockage was used as an anti-angiogenic treatment, while normoxia- and hypoxia-conditioned media from retinal pigment epithelium (RPE) cells was used as an angiogenic-inducer in this model. Iris vasculature was determined in vivo by noninvasive methods. Iris blood vessels were stained for platelet endothelial cell adhesion molecule-1 and vascular sprouts were counted as markers of angiogenesis. Expression of angiogenic and inflammatory factors in the puncture-induced model were determined by qPCR and western blot. Results Punctures led to increased neovascularization and sprouting of the iris. qPCR and protein analysis showed an increase of angiogenic factors, particularly in the plasminogen-activating receptor and inflammatory systems. VEGF-blockage partly reduced iris neovascularization, and treatment with hypoxia-conditioned RPE medium led to a statistically significant increase in iris neovascularization. Conclusions This study presents the first evidence of a puncture-induced iris angiogenesis model in the mouse. In a broader context, this novel in vivo model of neovascularization has the potential for noninvasive evaluation of angiogenesis modulating substances. PMID:28658313

  1. Neck Muscle Moment Arms Obtained In-Vivo from MRI: Effect of Curved and Straight Modeled Paths.

    PubMed

    Suderman, Bethany L; Vasavada, Anita N

    2017-08-01

    Musculoskeletal models of the cervical spine commonly represent neck muscles with straight paths. However, straight lines do not best represent the natural curvature of muscle paths in the neck, because the paths are constrained by bone and soft tissue. The purpose of this study was to estimate moment arms of curved and straight neck muscle paths using different moment arm calculation methods: tendon excursion, geometric, and effective torque. Curved and straight muscle paths were defined for two subject-specific cervical spine models derived from in vivo magnetic resonance images (MRI). Modeling neck muscle paths with curvature provides significantly different moment arm estimates than straight paths for 10 of 15 neck muscles (p < 0.05, repeated measures two-way ANOVA). Moment arm estimates were also found to be significantly different among moment arm calculation methods for 11 of 15 neck muscles (p < 0.05, repeated measures two-way ANOVA). In particular, using straight lines to model muscle paths can lead to overestimating neck extension moment. However, moment arm methods for curved paths should be investigated further, as different methods of calculating moment arm can provide different estimates.

  2. Arterial waveguide model for shear wave elastography: implementation and in vitro validation

    NASA Astrophysics Data System (ADS)

    Vaziri Astaneh, Ali; Urban, Matthew W.; Aquino, Wilkins; Greenleaf, James F.; Guddati, Murthy N.

    2017-07-01

    Arterial stiffness is found to be an early indicator of many cardiovascular diseases. Among various techniques, shear wave elastography has emerged as a promising tool for estimating local arterial stiffness through the observed dispersion of guided waves. In this paper, we develop efficient models for the computational simulation of guided wave dispersion in arterial walls. The models are capable of considering fluid-loaded tubes, immersed in fluid or embedded in a solid, which are encountered in in vitro/ex vivo, and in vivo experiments. The proposed methods are based on judiciously combining Fourier transformation and finite element discretization, leading to a significant reduction in computational cost while fully capturing complex 3D wave propagation. The developed methods are implemented in open-source code, and verified by comparing them with significantly more expensive, fully 3D finite element models. We also validate the models using the shear wave elastography of tissue-mimicking phantoms. The computational efficiency of the developed methods indicates the possibility of being able to estimate arterial stiffness in real time, which would be beneficial in clinical settings.

  3. Dose perturbations due to in vivo dosimetry with diodes.

    PubMed

    Alecu, R; Feldmeier, J J; Alecu, M

    1997-03-01

    In vivo dosimetry performed with semiconductor detectors is a reliable method for patient dose control. The purpose of this study is to evaluate the perturbations introduced in the patient's absorbed dose distribution by three types of commercially available diodes (Isorad, Sun Nuclear Corp.; model 114200, 114300 and 114400) from the same company and to present possible solutions for minimizing this side-effect.

  4. In Vivo Gene Therapy of Hemophilia B: Sustained Partial Correction in Factor IX-Deficient Dogs

    NASA Astrophysics Data System (ADS)

    Kay, Mark A.; Rothenberg, Steven; Landen, Charles N.; Bellinger, Dwight A.; Leland, Frances; Toman, Carol; Finegold, Milton; Thompson, Arthur R.; Read, M. S.; Brinkhous, Kenneth M.; Woo, Savio L. C.

    1993-10-01

    The liver represents a model organ for gene therapy. A method has been developed for hepatic gene transfer in vivo by the direct infusion of recombinant retroviral vectors into the portal vasculature, which results in the persistent expression of exogenous genes. To determine if these technologies are applicable for the treatment of hemophilia B patients, preclinical efficacy studies were done in a hemophilia B dog model. When the canine factor IX complementary DNA was transduced directly into the hepatocytes of affected dogs in vivo, the animals constitutively expressed low levels of canine factor IX for more than 5 months. Persistent expression of the clotting. factor resulted in reductions of whole blood clotting and partial thromboplastin times of the treated animals. Thus, long-term treatment of hemophilia B patients may be feasible by direct hepatic gene therapy in vivo.

  5. The Ex Vivo Eye Irritation Test as an alternative test method for serious eye damage/eye irritation.

    PubMed

    Spöler, Felix; Kray, Oya; Kray, Stefan; Panfil, Claudia; Schrage, Norbert F

    2015-07-01

    Ocular irritation testing is a common requirement for the classification, labelling and packaging of chemicals (substances and mixtures). The in vivo Draize rabbit eye test (OECD Test Guideline 405) is considered to be the regulatory reference method for the classification of chemicals according to their potential to induce eye injury. In the Draize test, chemicals are applied to rabbit eyes in vivo, and changes are monitored over time. If no damage is observed, the chemical is not categorised. Otherwise, the classification depends on the severity and reversibility of the damage. Alternative test methods have to be designed to match the classifications from the in vivo reference method. However, observation of damage reversibility is usually not possible in vitro. Within the present study, a new organotypic method based on rabbit corneas obtained from food production is demonstrated to close this gap. The Ex Vivo Eye Irritation Test (EVEIT) retains the full biochemical activity of the corneal epithelium, epithelial stem cells and endothelium. This permits the in-depth analysis of ocular chemical trauma beyond that achievable by using established in vitro methods. In particular, the EVEIT is the first test to permit the direct monitoring of recovery of all corneal layers after damage. To develop a prediction model for the EVEIT that is comparable to the GHS system, 37 reference chemicals were analysed. The experimental data were used to derive a three-level potency ranking of eye irritation and corrosion that best fits the GHS categorisation. In vivo data available in the literature were used for comparison. When compared with GHS classification predictions, the overall accuracy of the three-level potency ranking was 78%. The classification of chemicals as irritating versus non-irritating resulted in 96% sensitivity, 91% specificity and 95% accuracy. 2015 FRAME.

  6. Visualisation of distribution of gold nanoparticles in liver tissues ex vivo and in vitro using the method of optical coherence tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Genina, Elina A; Terentyuk, G S; Khlebtsov, B N

    2012-06-30

    The possibility of visualising the distribution of gold nanoparticles in liver by means of the method of optical coherence tomography is studied experimentally in model samples of beef liver in vitro and rat liver ex vivo. In the experiments we used the gold nanoparticles in the form of nanocages with resonance absorption in the near-IR spectral region. In the model studies the suspension of nanoparticles was applied to the surface of the sample, which then was treated with ultrasound. In the ex vivo studies the suspension of nanoparticles was injected to the laboratory rats intravenously. The image contrast and themore » optical depth of detection of blood vessels and liver structure components are calculated, as well as the depth of liver optical probing before and after the injection of nanoparticles. It was shown that the administration of the nanoparticle increases significantly the imaging contrast of liver blood vessels owing to the localisation of the nanoparticles therein.« less

  7. Therapeutic effects of autologous lymphocytes activated with trastuzumab for xenograft mouse models of human breast cancer.

    PubMed

    Nakagawa, Shinichiro; Matsuoka, Yusuke; Ichihara, Hideaki; Yoshida, Hitoji; Yoshida, Kenshi; Ueoka, Ryuichi

    2013-01-01

    Trastuzumab (TTZ) is molecular targeted drug used for metastatic breast cancer patients overexpressing human epidermal growth factor receptor 2 (HER2). Therapeutic effects of lymphocytes activated with TTZ (TTZ-LAK) using xenograft mouse models of human breast cancer (MDA-MB-453) cells were examined in vivo. Remarkable reduction of tumor volume in a xenograft mouse models intravenously treated with TTZ-LAK cells after the subcutaneously inoculated of MDA-MB-453 cells was verified in vivo. The migration of TTZ-LAK cells in tumor of mouse models subcutaneously inoculated MDA-MB-453 cells was observed on the basis of histological analysis using immunostaining with CD-3. Induction of apoptosis in tumor of xenograft mice treated with TTZ-LAK cells was observed in micrographs using terminal deoxynucleotidyl transferase-mediated deoxyuridine triphosphate nick-end labeling (TUNEL) method. It was noteworthy that the therapeutic effects of TTZ-LAK cells along with apoptosis were obtained for xenograft mouse models of human breast tumor in vivo.

  8. In Vivo Evaluation of Wearable Head Impact Sensors.

    PubMed

    Wu, Lyndia C; Nangia, Vaibhav; Bui, Kevin; Hammoor, Bradley; Kurt, Mehmet; Hernandez, Fidel; Kuo, Calvin; Camarillo, David B

    2016-04-01

    Inertial sensors are commonly used to measure human head motion. Some sensors have been tested with dummy or cadaver experiments with mixed results, and methods to evaluate sensors in vivo are lacking. Here we present an in vivo method using high speed video to test teeth-mounted (mouthguard), soft tissue-mounted (skin patch), and headgear-mounted (skull cap) sensors during 6-13 g sagittal soccer head impacts. Sensor coupling to the skull was quantified by displacement from an ear-canal reference. Mouthguard displacements were within video measurement error (<1 mm), while the skin patch and skull cap displaced up to 4 and 13 mm from the ear-canal reference, respectively. We used the mouthguard, which had the least displacement from skull, as the reference to assess 6-degree-of-freedom skin patch and skull cap measurements. Linear and rotational acceleration magnitudes were over-predicted by both the skin patch (with 120% NRMS error for a(mag), 290% for α(mag)) and the skull cap (320% NRMS error for a(mag), 500% for α(mag)). Such over-predictions were largely due to out-of-plane motion. To model sensor error, we found that in-plane skin patch linear acceleration in the anterior-posterior direction could be modeled by an underdamped viscoelastic system. In summary, the mouthguard showed tighter skull coupling than the other sensor mounting approaches. Furthermore, the in vivo methods presented are valuable for investigating skull acceleration sensor technologies.

  9. In vitro and in vivo comparisons of constant resistance AC iontophoresis and DC iontophoresis.

    PubMed

    Li, S Kevin; Higuchi, William I; Zhu, Honggang; Kern, Steven E; Miller, David J; Hastings, Matthew S

    2003-09-04

    A previous in vitro constant electrical resistance alternating current (AC) iontophoresis study with human epidermal membrane (HEM) and a model neutral permeant has shown less inter- and intra-sample variability in iontophoretic transport relative to conventional constant direct current (DC) iontophoresis. The objectives of the present study were to address the following questions. (1) Can the skin electrical resistance be maintained at a constant level by AC in humans in vivo? (2) Are the in vitro data with HEM representative of those in vivo? (3) Does constant skin resistance AC iontophoresis have less inter- and intra-sample variability than conventional constant current DC iontophoresis in vivo? (4) What are the electrical and the barrier properties of skin during iontophoresis in vivo? In the present study, in vitro HEM experiments were carried out with the constant resistance AC and the conventional constant current DC methods using mannitol and glucose as the neutral model permeants. In vivo human experiments were performed using glucose as the permeant with a constant skin resistance AC only protocol and two conventional constant current DC methods (continuous constant current DC and constant current DC with its polarity alternated every 10 min with a 3:7 on:off duty cycle). Constant current DC iontophoresis was conducted with commercial constant current DC devices, and constant resistance AC iontophoresis was carried out by reducing and maintaining the skin resistance at a constant target value with AC supplied from a function generator. This study shows that (1) skin electrical resistance can be maintained at a constant level during AC iontophoresis in vivo; (2) HEM in vitro and human skin in vivo demonstrate similar electrical and barrier properties, and these properties are consistent with our previous findings; (3) there is general qualitative and semi-quantitative agreement between the HEM data in vitro and human skin data in vivo; and (4) constant skin resistance AC iontophoresis generally provides less inter- and intra-subject variability than conventional constant current DC.

  10. Exploring Normalization and Network Reconstruction Methods using In Silico and In Vivo Models

    EPA Science Inventory

    Abstract: Lessons learned from the recent DREAM competitions include: The search for the best network reconstruction method continues, and we need more complete datasets with ground truth from more complex organisms. It has become obvious that the network reconstruction methods t...

  11. A hybrid approach to determining cornea mechanical properties in vivo using a combination of nano-indentation and inverse finite element analysis.

    PubMed

    Abyaneh, M H; Wildman, R D; Ashcroft, I A; Ruiz, P D

    2013-11-01

    An analysis of the material properties of porcine corneas has been performed. A simple stress relaxation test was performed to determine the viscoelastic properties and a rheological model was built based on the Generalized Maxwell (GM) approach. A validation experiment using nano-indentation showed that an isotropic GM model was insufficient for describing the corneal material behaviour when exposed to a complex stress state. A new technique was proposed for determining the properties, using a combination of nano-indentation experiment, an isotropic and orthotropic GM model and inverse finite element method. The good agreement using this method suggests that this is a promising technique for measuring material properties in vivo and further work should focus on the reliability of the approach in practice. © 2013 Elsevier Ltd. All rights reserved.

  12. Whole-brain ex-vivo quantitative MRI of the cuprizone mouse model

    PubMed Central

    Hurley, Samuel A.; Vernon, Anthony C.; Torres, Joel; Dell’Acqua, Flavio; Williams, Steve C.R.; Cash, Diana

    2016-01-01

    Myelin is a critical component of the nervous system and a major contributor to contrast in Magnetic Resonance (MR) images. However, the precise contribution of myelination to multiple MR modalities is still under debate. The cuprizone mouse is a well-established model of demyelination that has been used in several MR studies, but these have often imaged only a single slice and analysed a small region of interest in the corpus callosum. We imaged and analyzed the whole brain of the cuprizone mouse ex-vivo using high-resolution quantitative MR methods (multi-component relaxometry, Diffusion Tensor Imaging (DTI) and morphometry) and found changes in multiple regions, including the corpus callosum, cerebellum, thalamus and hippocampus. The presence of inflammation, confirmed with histology, presents difficulties in isolating the sensitivity and specificity of these MR methods to demyelination using this model. PMID:27833805

  13. In Vivo Methods for the Assessment of Topical Drug Bioavailability

    PubMed Central

    Herkenne, Christophe; Alberti, Ingo; Naik, Aarti; Kalia, Yogeshvar N.; Mathy, François-Xavier; Préat, Véronique

    2007-01-01

    This paper reviews some current methods for the in vivo assessment of local cutaneous bioavailability in humans after topical drug application. After an introduction discussing the importance of local drug bioavailability assessment and the limitations of model-based predictions, the focus turns to the relevance of experimental studies. The available techniques are then reviewed in detail, with particular emphasis on the tape stripping and microdialysis methodologies. Other less developed techniques, including the skin biopsy, suction blister, follicle removal and confocal Raman spectroscopy techniques are also described. PMID:17985216

  14. Development of an in situ evaluation system for neural cells using extracellular matrix-modeled gel culture.

    PubMed

    Nagai, Takayuki; Ikegami, Yasuhiro; Mizumachi, Hideyuki; Shirakigawa, Nana; Ijima, Hiroyuki

    2017-10-01

    Two-dimensional monolayer culture is the most popular cell culture method. However, the cells may not respond as they do in vivo because the culture conditions are different from in vivo conditions. However, hydrogel-embedding culture, which cultures cells in a biocompatible culture substrate, can produce in vivo-like cell responses, but in situ evaluation of cells in a gel is difficult. In this study, we realized an in vivo-like environment in vitro to produce cell responses similar to those in vivo and established an in situ evaluation system for hydrogel-embedded cell responses. The extracellular matrix (ECM)-modeled gel consisted of collagen and heparin (Hep-col) to mimic an in vivo-like environment. The Hep-col gel could immobilize growth factors, which is important for ECM functions. Neural stem/progenitor cells cultured in the Hep-col gel grew and differentiated more actively than in collagen, indicating an in vivo-like environment in the Hep-col gel. Second, a thin-layered gel culture system was developed to realize in situ evaluation of the gel-embedded cells. Cells in a 200-μm-thick gel could be evaluated clearly by a phase-contrast microscope and immunofluorescence staining through reduced optical and diffusional effects. Finally, we found that the neural cells cultured in this system had synaptic connections and neuronal action potentials by immunofluorescence staining and Ca 2+ imaging. In conclusion, this culture method may be a valuable evaluation system for neurotoxicity testing. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  15. A new alternative method for testing skin irritation using a human skin model: a pilot study.

    PubMed

    Miles, A; Berthet, A; Hopf, N B; Gilliet, M; Raffoul, W; Vernez, D; Spring, P

    2014-03-01

    Studies assessing skin irritation to chemicals have traditionally used laboratory animals; however, such methods are questionable regarding their relevance for humans. New in vitro methods have been validated, such as the reconstructed human epidermis (RHE) model (Episkin®, Epiderm®). The comparison (accuracy) with in vivo results such as the 4-h human patch test (HPT) is 76% at best (Epiderm®). There is a need to develop an in vitro method that better simulates the anatomo-pathological changes encountered in vivo. To develop an in vitro method to determine skin irritation using human viable skin through histopathology, and compare the results of 4 tested substances to the main in vitro methods and in vivo animal method (Draize test). Human skin removed during surgery was dermatomed and mounted on an in vitro flow-through diffusion cell system. Ten chemicals with known non-irritant (heptylbutyrate, hexylsalicylate, butylmethacrylate, isoproturon, bentazon, DEHP and methylisothiazolinone (MI)) and irritant properties (folpet, 1-bromohexane and methylchloroisothiazolinone (MCI/MI)), a negative control (sodiumchloride) and a positive control (sodiumlaurylsulphate) were applied. The skin was exposed at least for 4h. Histopathology was performed to investigate irritation signs (spongiosis, necrosis, vacuolization). We obtained 100% accuracy with the HPT model; 75% with the RHE models and 50% with the Draize test for 4 tested substances. The coefficients of variation (CV) between our three test batches were <0.1, showing good reproducibility. Furthermore, we reported objectively histopathological irritation signs (irritation scale): strong (folpet), significant (1-bromohexane), slight (MCI/MI at 750/250ppm) and none (isoproturon, bentazon, DEHP and MI). This new in vitro test method presented effective results for the tested chemicals. It should be further validated using a greater number of substances; and tested in different laboratories in order to suitably evaluate reproducibility. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Monte Carlo simulations of coherent backscatter for identification of the optical coefficients of biological tissues in vivo

    NASA Astrophysics Data System (ADS)

    Eddowes, M. H.; Mills, T. N.; Delpy, D. T.

    1995-05-01

    A Monte Carlo model of light backscattered from turbid media has been used to simulate the effects of weak localization in biological tissues. A validation technique is used that implies that for the scattering and absorption coefficients and for refractive index mismatches found in tissues, the Monte Carlo method is likely to provide more accurate results than the methods previously used. The model also has the ability to simulate the effects of various illumination profiles and other laboratory-imposed conditions. A curve-fitting routine has been developed that might be used to extract the optical coefficients from the angular intensity profiles seen in experiments on turbid biological tissues, data that could be obtained in vivo.

  17. Studying NK cell responses to ectromelia virus infections in mice.

    PubMed

    Fang, Min; Sigal, Luis

    2010-01-01

    Here we describe methods for the in vivo study of antiviral NK cell responses using the mouse Orthopoxvirus ectromelia virus as a model, the agent of mousepox. The methods include those specific for the preparation and use of ectromelia virus such as the production of virus stocks in tissue culture and in live mice, the purification of virus stocks, the titration of virus stocks and virus loads in organs, and the infection of mice. The chapter also includes methods for the specific study of NK cell responses in infected mice such as the preparation of organs (lymph nodes, spleen, and liver) for analysis, the study of NK cell responses by flow cytometry, the adoptive transfer of NK cells, the measurement of NK cell cytolytic activity ex vivo and in vivo, and the determination of NK cell proliferation by bromodeoxyuridine loading or by dilution of carboxyfluorescein diacetate succinimidyl ester (CFSE).

  18. {sup 19}F NMR measurements of NO production in hypertensive ISIAH and OXYS rats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bobko, Andrey A.; Sergeeva, Svetlana V.; Bagryanskaya, Elena G.

    2005-05-06

    Recently we demonstrated the principal possibility of application of {sup 19}F NMR spin-trapping technique for in vivo {sup {center_dot}}NO detection [Free Radic. Biol. Med. 36 (2004) 248]. In the present study, we employed this method to elucidate the significance of {sup {center_dot}}NO availability in animal models of hypertension. In vivo {sup {center_dot}}NO-induced conversion of the hydroxylamine of the fluorinated nitronyl nitroxide (HNN) to the hydroxylamine of the iminonitroxide (HIN) in hypertensive ISIAH and OXYS rat strains and normotensive Wistar rat strain was measured. Significantly lower HIN/HNN ratios were measured in the blood of the hypertensive rats. The NMR data weremore » found to positively correlate with the levels of nitrite/nitrate evaluated by Griess method and negatively correlate with the blood pressure. In comparison with other traditionally used methods {sup 19}F NMR spectroscopy allows in vivo evaluation of {sup {center_dot}}NO production and provides the basis for in vivo {sup {center_dot}}NO imaging.« less

  19. In vivo gene correction with targeted sequence substitution through microhomology-mediated end joining.

    PubMed

    Shin, Jeong Hong; Jung, Soobin; Ramakrishna, Suresh; Kim, Hyongbum Henry; Lee, Junwon

    2018-07-07

    Genome editing technology using programmable nucleases has rapidly evolved in recent years. The primary mechanism to achieve precise integration of a transgene is mainly based on homology-directed repair (HDR). However, an HDR-based genome-editing approach is less efficient than non-homologous end-joining (NHEJ). Recently, a microhomology-mediated end-joining (MMEJ)-based transgene integration approach was developed, showing feasibility both in vitro and in vivo. We expanded this method to achieve targeted sequence substitution (TSS) of mutated sequences with normal sequences using double-guide RNAs (gRNAs), and a donor template flanking the microhomologies and target sequence of the gRNAs in vitro and in vivo. Our method could realize more efficient sequence substitution than the HDR-based method in vitro using a reporter cell line, and led to the survival of a hereditary tyrosinemia mouse model in vivo. The proposed MMEJ-based TSS approach could provide a novel therapeutic strategy, in addition to HDR, to achieve gene correction from a mutated sequence to a normal sequence. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Free Radical Imaging Using In Vivo Dynamic Nuclear Polarization-MRI.

    PubMed

    Utsumi, Hideo; Hyodo, Fuminori

    2015-01-01

    Redox reactions that generate free radical intermediates are essential to metabolic processes, and their intermediates can produce reactive oxygen species, which may promote diseases related to oxidative stress. The development of an in vivo electron spin resonance (ESR) spectrometer and its imaging enables us noninvasive and direct measurement of in vivo free radical reactions in living organisms. The dynamic nuclear polarization magnetic resonance imaging (DNP-MRI), also called PEDRI or OMRI, is also a new imaging method for observing free radical species in vivo. The spatiotemporal resolution of free radical imaging with DNP-MRI is comparable with that in MRI, and each of the radical species can be distinguished in the spectroscopic images by changing the frequency or magnetic field of ESR irradiation. Several kinds of stable nitroxyl radicals were used as spin probes to detect in vivo redox reactions. The signal decay of nitroxyl probes, which is determined with in vivo DNP-MRI, reflects the redox status under oxidative stress, and the signal decay is suppressed by prior administration of antioxidants. In addition, DNP-MRI can also visualize various intermediate free radicals from the intrinsic redox molecules. This noninvasive method, in vivo DNP-MRI, could become a useful tool for investigating the mechanism of oxidative injuries in animal disease models and the in vivo effects of antioxidant drugs. © 2015 Elsevier Inc. All rights reserved.

  1. Gold nanoparticles synthesis and biological activity estimation in vitro and in vivo.

    PubMed

    Rieznichenko, L S; Dybkova, S M; Gruzina, T G; Ulberg, Z R; Todor, I N; Lukyanova, N Yu; Shpyleva, S I; Chekhun, V F

    2012-01-01

    The aim of the work was the synthesis of gold nanoparticles (GNP) of different sizes and the estimation of their biological activity in vitro and in vivo. Water dispersions of gold nanoparticles of different sizes have been synthesized by Davis method and characterized by laser-correlation spectroscopy and transmission electron microscopy methods. The GNP interaction with tumor cells has been visualized by confocal microscopy method. The enzyme activity was determined by standard biochemical methods. GNP distribution and content in organs and tissues have been determined via atomic-absorption spectrometry method; genotoxic influence has been estimated by "Comet-assay" method. The GNP size-dependent accumulation in cultured U937 tumor cells and their ability to modulate U937 cell membrane Na(+),K(+)-АТР-ase activity value has been revealed in vitro. Using in vivo model of Guerin carcinoma it has been shown that GNP possess high affinity to tumor cells. Our results indicate the perspectives of use of the synthesized GNP water dispersions for cancer diagnostics and treatment. It's necessary to take into account a size-dependent biosafety level of nanoparticles.

  2. Application of NIR fluorescent markers to quantify expression level of HER2 receptors in carcinomas in vivo

    NASA Astrophysics Data System (ADS)

    Chernomordik, Victor; Hassan, Moinuddin; Lee, Sang Bong; Zielinski, Rafal; Capala, Jacek; Gandjbakhche, Amir

    2010-02-01

    HER2 overexpression has been associated with a poor prognosis and resistance to therapy in breast cancer patients. However, quantitative estimates of this important characteristic have been limited to ex vivo ELISA essays of tissue biopsies and/or PET. We develop a novel approach in optical imaging, involving specific probes, not interfering with the binding of the therapeutic agents, thus, excluding competition between therapy and imaging. Affibody-based molecular probes seem to be ideal for in vivo analysis of HER2 receptors using near-infrared optical imaging. Fluorescence intensity distributions, originating from specific markers in the tumor area, can reveal the corresponding fluorophore concentration. We use temporal changes of the signal from a contrast agent, conjugated with HER2-specific Affibody as a signature to monitor in vivo the receptors status in mice with different HER2 over-expressed tumor models. Kinetic model, incorporating saturation of the bound ligands in the tumor area due to HER2 receptor concentration, is suggested to analyze relationship between tumor cell characteristics, i.e., HER2 overexpression, obtained by traditional ("golden standard") ex vivo methods (ELISA), and parameters, estimated from the series of images in vivo. Observed correlation between these parameters and HER2 overexpression substantiates application of our approach to quantify HER2 concentration in vivo.

  3. In vivo electric conductivity of cervical cancer patients based on B₁⁺ maps at 3T MRI.

    PubMed

    Balidemaj, E; de Boer, P; van Lier, A L H M W; Remis, R F; Stalpers, L J A; Westerveld, G H; Nederveen, A J; van den Berg, C A T; Crezee, J

    2016-02-21

    The in vivo electric conductivity (σ) values of tissue are essential for accurate electromagnetic simulations and specific absorption rate (SAR) assessment for applications such as thermal dose computations in hyperthermia. Currently used σ-values are mostly based on ex vivo measurements. In this study the conductivity of human muscle, bladder content and cervical tumors is acquired non-invasively in vivo using MRI. The conductivity of 20 cervical cancer patients was measured with the MR-based electric properties tomography method on a standard 3T MRI system. The average in vivo σ-value of muscle is 14% higher than currently used in human simulation models. The σ-value of bladder content is an order of magnitude higher than the value for bladder wall tissue that is used for the complete bladder in many models. Our findings are confirmed by various in vivo animal studies from the literature. In cervical tumors, the observed average conductivity was 13% higher than the literature value reported for cervical tissue. Considerable deviations were found for the electrical conductivity observed in this study and the commonly used values for SAR assessment, emphasizing the importance of acquiring in vivo conductivity for more accurate SAR assessment in various applications.

  4. Murine models of breast cancer bone metastasis

    PubMed Central

    Wright, Laura E; Ottewell, Penelope D; Rucci, Nadia; Peyruchaud, Olivier; Pagnotti, Gabriel M; Chiechi, Antonella; Buijs, Jeroen T; Sterling, Julie A

    2016-01-01

    Bone metastases cause significant morbidity and mortality in late-stage breast cancer patients and are currently considered incurable. Investigators rely on translational models to better understand the pathogenesis of skeletal complications of malignancy in order to identify therapeutic targets that may ultimately prevent and treat solid tumor metastasis to bone. Many experimental models of breast cancer bone metastases are in use today, each with its own caveats. In this methods review, we characterize the bone phenotype of commonly utilized human- and murine-derived breast cell lines that elicit osteoblastic and/or osteolytic destruction of bone in mice and report methods for optimizing tumor-take in murine models of bone metastasis. We then provide protocols for four of the most common xenograft and syngeneic inoculation routes for modeling breast cancer metastasis to the skeleton in mice, including the intra-cardiac, intra-arterial, orthotopic and intra-tibial methods of tumor cell injection. Recommendations for in vivo and ex vivo assessment of tumor progression and bone destruction are provided, followed by discussion of the strengths and limitations of the available tools and translational models that aid investigators in the study of breast cancer metastasis to bone. PMID:27867497

  5. Non-Invasive In Vivo Ultrasound Temperature Estimation

    NASA Astrophysics Data System (ADS)

    Bayat, Mahdi

    New emerging technologies in thermal therapy require precise monitoring and control of the delivered thermal dose in a variety of situations. The therapeutic temperature changes in target tissues range from few degrees for releasing chemotherapy drugs encapsulated in the thermosensitive liposomes to boiling temperatures in complete ablation of tumors via cell necrosis. High intensity focused ultrasound (HIFU) has emerged as a promising modality for noninvasive surgery due to its ability to create precise mechanical and thermal effects at the target without affecting surrounding tissues. An essential element in all these procedures, however, is accurate estimation of the target tissue temperature during the procedure to ensure its safety and efficacy. The advent of diagnostic imaging tools for guidance of thermal therapy was a key factor in the clinical acceptance of these minimally invasive or noninvasive methods. More recently, ultrasound and magnetic resonance (MR) thermography techniques have been proposed for guidance, monitoring, and control of noninvasive thermal therapies. MR thermography has shown acceptable sensitivity and accuracy in imaging temperature change and it is currently FDA-approved on clinical HIFU units. However, it suffers from limitations like cost of integration with ultrasound therapy system and slow rate of imaging for real time guidance. Ultrasound, on the other hand, has the advantage of real time imaging and ease of integration with the therapy system. An infinitesimal model for imaging temperature change using pulse-echo ultrasound has been demonstrated, including in vivo small-animal imaging. However, this model suffers from limitations that prevent demonstration in more clinically-relevant settings. One limitation stems from the infinitesimal nature of the model, which results in spatial inconsistencies of the estimated temperature field. Another limitation is the sensitivity to tissue motion and deformation during in vivo, which could result in significant artifacts. The first part of this thesis addresses the first limitation by introducing the Recursive Echo Strain Filter (RESF) as a new temperature reconstruction model which largely corrects for the spatial inconsistencies resulting from the infinitesimal model. The performance of this model is validated using the data collected during sub therapeutic temperature changes in the tissue mimicking phantom as well as ex vivo tissue blocks. The second part of this thesis deals with in vivo ultrasound thermography. Tissue deformations caused by natural motions (e.g. respiration, gasping, blood pulsation etc) can create non-thermal changes to the ultrasound echoes which are not accounted for in the derivation of physical model for temperature estimation. These fluctuations can create severe artifacts in the estimated temperature field. Using statistical signal processing techniques an adaptive method is presented which takes advantage of the localized and global availability of these interference patterns and use this data to enhance the estimated temperature in the region of interest. We then propose a model based technique for continuous tracking of temperature in the presence of natural motion and deformation. The method uses the direct discretization of the transient bioheat equation to derive a state space model of temperature change. This model is then used to build a linear estimator based on the Kalman filtering capable of robust estimation of temperature change in the presence of tissue motion and deformation. The robustness of the adaptive and model-based models in removing motion and deformation artifacts is demonstrated using data from in vivo experiments. Both methods are shown to provide effective cancellation of the artifacts with minimal effect on the expected temperature dynamics.

  6. Establishment of a new in vitro test method for evaluation of eye irritancy using a reconstructed human corneal epithelial model, LabCyte CORNEA-MODEL.

    PubMed

    Katoh, Masakazu; Hamajima, Fumiyasu; Ogasawara, Takahiro; Hata, Ken-ichiro

    2013-12-01

    Finding in vitro eye irritation testing alternatives to animal testing such as the Draize eye test, which uses rabbits, is essential from the standpoint of animal welfare. It has been developed a reconstructed human corneal epithelial model, the LabCyte CORNEA-MODEL, which has a representative corneal epithelium-like structure. Protocol optimization (pre-validation study) was examined in order to establish a new alternative method for eye irritancy evaluation with this model. From the results of the optimization experiments, the application periods for chemicals were set at 1min for liquid chemicals or 24h for solid chemicals, and the post-exposure incubation periods were set at 24h for liquids or zero for solids. If the viability was less than 50%, the chemical was judged to be an eye irritant. Sixty-one chemicals were applied in the optimized protocol using the LabCyte CORNEA-MODEL and these results were evaluated in correlation with in vivo results. The predictions of the optimized LabCyte CORNEA-MODEL eye irritation test methods were highly correlated with in vivo eye irritation (sensitivity 100%, specificity 80.0%, and accuracy 91.8%). These results suggest that the LabCyte CORNEA-MODEL eye irritation test could be useful as an alternative method to the Draize eye test. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Spatiotemporal Distribution of β-Amyloid in Alzheimer Disease Is the Result of Heterogeneous Regional Carrying Capacities.

    PubMed

    Whittington, Alex; Sharp, David J; Gunn, Roger N

    2018-05-01

    β-amyloid (Aβ) accumulation in the brain is 1 of 2 pathologic hallmarks of Alzheimer disease (AD), and the spatial distribution of Aβ has been studied extensively ex vivo. Methods: We applied mathematical modeling to Aβ in vivo PET imaging data to investigate competing theories of Aβ spread in AD. Results: Our results provided evidence that Aβ accumulation starts in all brain regions simultaneously and that its spatiotemporal distribution is due to heterogeneous regional carrying capacities (regional maximum possible concentration of Aβ) for the aggregated protein rather than to longer-term spreading from seed regions. Conclusion: The in vivo spatiotemporal distribution of Aβ in AD can be mathematically modeled using a logistic growth model in which the Aβ carrying capacity is heterogeneous across the brain but the exponential growth rate and time of half maximal Aβ concentration are constant. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  8. Determination of oral mucosal Poisson's ratio and coefficient of friction from in-vivo contact pressure measurements.

    PubMed

    Chen, Junning; Suenaga, Hanako; Hogg, Michael; Li, Wei; Swain, Michael; Li, Qing

    2016-01-01

    Despite their considerable importance to biomechanics, there are no existing methods available to directly measure apparent Poisson's ratio and friction coefficient of oral mucosa. This study aimed to develop an inverse procedure to determine these two biomechanical parameters by utilizing in vivo experiment of contact pressure between partial denture and beneath mucosa through nonlinear finite element (FE) analysis and surrogate response surface (RS) modelling technique. First, the in vivo denture-mucosa contact pressure was measured by a tactile electronic sensing sheet. Second, a 3D FE model was constructed based on the patient CT images. Third, a range of apparent Poisson's ratios and the coefficients of friction from literature was considered as the design variables in a series of FE runs for constructing a RS surrogate model. Finally, the discrepancy between computed in silico and measured in vivo results was minimized to identify the best matching Poisson's ratio and coefficient of friction. The established non-invasive methodology was demonstrated effective to identify such biomechanical parameters of oral mucosa and can be potentially used for determining the biomaterial properties of other soft biological tissues.

  9. An Accelerated Release Method of Risperidone Loaded PLGA Microspheres with Good IVIVC.

    PubMed

    Hu, Xiaoqin; Zhang, Jianwei; Tang, Xuemei; Li, Mingyuan; Ma, Siyu; Liu, Cheng; Gao, Yue; Zhang, Yue; Liu, Yan; Yu, Fanglin; Yang, Yang; Guo, Jia; Li, Zhiping; Mei, Xingguo

    2018-01-01

    A long release period lasting several days or several weeks is always needed and thereby it is tedious and time consuming to screen formulations of such microspheres with so long release period and evaluate their release profiles in vitro with conventional long-term or "real-time" release method. So, an accelerated release testing of such system is necessary for formulation design as well as quality control purpose. The purpose of this study is to obtain an accelerated release method of risperidone loaded poly(lactic-co-glycolic acid) (PLGA) microspheres with good in vitro/in vivo correlation (IVIVC). Two formulations of risperidone loaded PLGA microspheres used for evaluating IVIVC were prepared by O/W method. The accelerated release condition was optimized by investigating the effect of pH, osmotic pressure, temperature and ethanol concentration on the release of risperidone from microspheres and the in vitro accelerated release profiles of risperidone from PLGA microspheres were obtained under this optimized accelerated release condition. The plasma concentration of risperidone were also detected after subcutaneous injection of risperidone loaded microspheres to rats. The in vivo cumulative absorption profiles were then calculated using Wagner-Nelson model, Loo- Riegelman model and numerical convolution model, respectively. The correlation between in vitro accelerated release and in vivo cumulative absorption were finally evaluated with Least Square Method. It was shown that temperature and ethanol concentration significantly affected the release of risperidone from the microspheres while pH and osmotic pressure of release media slightly affected the release behavior of risperidone. The in vitro release of risperidone from microspheres were finally undergone in PBS (pH7.0, 300mosm) with 20% (V/V) ethanol at 45°C. The sustained and complete release of risperidone was observed in both formulations under the accelerated release condition although these two release profiles were dissimilar. The correlation coefficients (R2) of IVIVC were all above 0.95 and the slopes were all between 0.9564 and 1.1868 in spite of fitted model and microsphere formulation. An in vitro accelerated release method of risperidone microspheres with good IVIVC was established in this paper and this accelerated release method was supposed to have great potential in both in vivo performance prediction and quality control for risperidone loaded PLGA microspheres. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  10. Tissue vascularization through 3D printing: Will technology bring us flow?

    PubMed

    Paulsen, S J; Miller, J S

    2015-05-01

    Though in vivo models provide the most physiologically relevant environment for studying tissue function, in vitro studies provide researchers with explicit control over experimental conditions and the potential to develop high throughput testing methods. In recent years, advancements in developmental biology research and imaging techniques have significantly improved our understanding of the processes involved in vascular development. However, the task of recreating the complex, multi-scale vasculature seen in in vivo systems remains elusive. 3D bioprinting offers a potential method to generate controlled vascular networks with hierarchical structure approaching that of in vivo networks. Bioprinting is an interdisciplinary field that relies on advances in 3D printing technology along with advances in imaging and computational modeling, which allow researchers to monitor cellular function and to better understand cellular environment within the printed tissue. As bioprinting technologies improve with regards to resolution, printing speed, available materials, and automation, 3D printing could be used to generate highly controlled vascularized tissues in a high throughput manner for use in regenerative medicine and the development of in vitro tissue models for research in developmental biology and vascular diseases. © 2015 Wiley Periodicals, Inc.

  11. In Vivo Imaging of Immuno-Spin Trapped Radicals With Molecular Magnetic Resonance Imaging in a Diabetic Mouse Model

    PubMed Central

    Towner, Rheal A.; Smith, Nataliya; Saunders, Debra; Henderson, Michael; Downum, Kristen; Lupu, Florea; Silasi-Mansat, Robert; Ramirez, Dario C.; Gomez-Mejiba, Sandra E.; Bonini, Marcelo G.; Ehrenshaft, Marilyn; Mason, Ronald P.

    2012-01-01

    Oxidative stress plays a major role in diabetes. In vivo levels of membrane-bound radicals (MBRs) in a streptozotocin-induced diabetic mouse model were uniquely detected by combining molecular magnetic resonance imaging (mMRI) and immunotrapping techniques. An anti-DMPO (5,5-dimethyl-1-pyrroline N-oxide) antibody (Ab) covalently bound to an albumin (BSA)-Gd (gadolinium)-DTPA (diethylene triamine penta acetic acid)-biotin MRI contrast agent (anti-DMPO probe), and mMRI, were used to detect in vivo levels of DMPO-MBR adducts in kidneys, livers, and lungs of diabetic mice, after DMPO administration. Magnetic resonance signal intensities, which increase in the presence of a Gd-based molecular probe, were significantly higher within the livers, kidneys, and lungs of diabetic animals administered the anti-DMPO probe compared with controls. Fluorescence images validated the location of the anti-DMPO probe in excised tissues via conjugation of streptavidin-Cy3, which targeted the probe biotin moiety, and immunohistochemistry was used to validate the presence of DMPO adducts in diabetic mouse livers. This is the first report of noninvasively imaging in vivo levels of MBRs within any disease model. This method can be specifically applied toward diabetes models for in vivo assessment of free radical levels, providing an avenue to more fully understand the role of free radicals in diabetes. PMID:22698922

  12. Sparse and Adaptive Diffusion Dictionary (SADD) for recovering intra-voxel white matter structure.

    PubMed

    Aranda, Ramon; Ramirez-Manzanares, Alonso; Rivera, Mariano

    2015-12-01

    On the analysis of the Diffusion-Weighted Magnetic Resonance Images, multi-compartment models overcome the limitations of the well-known Diffusion Tensor model for fitting in vivo brain axonal orientations at voxels with fiber crossings, branching, kissing or bifurcations. Some successful multi-compartment methods are based on diffusion dictionaries. The diffusion dictionary-based methods assume that the observed Magnetic Resonance signal at each voxel is a linear combination of the fixed dictionary elements (dictionary atoms). The atoms are fixed along different orientations and diffusivity profiles. In this work, we present a sparse and adaptive diffusion dictionary method based on the Diffusion Basis Functions Model to estimate in vivo brain axonal fiber populations. Our proposal overcomes the following limitations of the diffusion dictionary-based methods: the limited angular resolution and the fixed shapes for the atom set. We propose to iteratively re-estimate the orientations and the diffusivity profile of the atoms independently at each voxel by using a simplified and easier-to-solve mathematical approach. As a result, we improve the fitting of the Diffusion-Weighted Magnetic Resonance signal. The advantages with respect to the former Diffusion Basis Functions method are demonstrated on the synthetic data-set used on the 2012 HARDI Reconstruction Challenge and in vivo human data. We demonstrate that improvements obtained in the intra-voxel fiber structure estimations benefit brain research allowing to obtain better tractography estimations. Hence, these improvements result in an accurate computation of the brain connectivity patterns. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Intracellular Redox State Revealed by In Vivo 31P MRS Measurement of NAD+ and NADH Contents in Brains

    PubMed Central

    Lu, Ming; Zhu, Xiao-Hong; Zhang, Yi; Chen, Wei

    2015-01-01

    Purpose Nicotinamide adenine dinucleotide (NAD), in oxidized (NAD+) or reduced (NADH) form, plays key roles in cellular metabolism. Intracellular NAD+/NADH ratio represents the cellular redox state; however, it is difficult to measure in vivo. We report here a novel in vivo 31P MRS method for noninvasive measurement of intracellular NAD concentrations and NAD+/NADH ratio in the brain. Methods It uses a theoretical model to describe the NAD spectral patterns at a given field for quantification. Standard NAD solutions and independent cat brain measurements at 9.4 T and 16.4 T were used to evaluate this method. We also measured T1 values of brain NAD. Results Model simulation and studies of solutions and brains indicate that the proposed method can quantify submillimolar NAD concentrations with reasonable accuracy if adequate 31P MRS signal-to-noise ratio and linewidth were obtained. The NAD concentrations and NAD+/NADH ratio of cat brains measured at 16.4 T and 9.4 T were consistent despite the significantly different T1 values and NAD spectra patterns at two fields. Conclusion This newly established 31P MRS method makes it possible for the first time to noninvasively study the intracellular redox state and its roles in brain functions and diseases, and it can potentially be applied to other organs. PMID:23843330

  14. Accuracy of Monte Carlo simulations compared to in-vivo MDCT dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bostani, Maryam, E-mail: mbostani@mednet.ucla.edu; McMillan, Kyle; Cagnon, Chris H.

    Purpose: The purpose of this study was to assess the accuracy of a Monte Carlo simulation-based method for estimating radiation dose from multidetector computed tomography (MDCT) by comparing simulated doses in ten patients to in-vivo dose measurements. Methods: MD Anderson Cancer Center Institutional Review Board approved the acquisition of in-vivo rectal dose measurements in a pilot study of ten patients undergoing virtual colonoscopy. The dose measurements were obtained by affixing TLD capsules to the inner lumen of rectal catheters. Voxelized patient models were generated from the MDCT images of the ten patients, and the dose to the TLD for allmore » exposures was estimated using Monte Carlo based simulations. The Monte Carlo simulation results were compared to the in-vivo dose measurements to determine accuracy. Results: The calculated mean percent difference between TLD measurements and Monte Carlo simulations was −4.9% with standard deviation of 8.7% and a range of −22.7% to 5.7%. Conclusions: The results of this study demonstrate very good agreement between simulated and measured doses in-vivo. Taken together with previous validation efforts, this work demonstrates that the Monte Carlo simulation methods can provide accurate estimates of radiation dose in patients undergoing CT examinations.« less

  15. A novel, simplified ex vivo method for measuring water exchange performance of heat and moisture exchangers for tracheostomy application.

    PubMed

    van den Boer, Cindy; Muller, Sara H; Vincent, Andrew D; Züchner, Klaus; van den Brekel, Michiel W M; Hilgers, Frans J M

    2013-09-01

    Breathing through a tracheostomy results in insufficient warming and humidification of inspired air. This loss of air-conditioning can be partially compensated for with the application of a heat and moisture exchanger (HME) over the tracheostomy. In vitro (International Organization for Standardization [ISO] standard 9360-2:2001) and in vivo measurements of the effects of an HME are complex and technically challenging. The aim of this study was to develop a simple method to measure the ex vivo HME performance comparable with previous in vitro and in vivo results. HMEs were weighed at the end of inspiration and at the end of expiration at different breathing volumes. Four HMEs (Atos Medical, Hörby, Sweden) with known in vivo humidity and in vitro water loss values were tested. The associations between weight change, volume, and absolute humidity were determined using both linear and non-linear mixed effects models. The rating between the 4 HMEs by weighing correlated with previous intra-tracheal measurements (R(2) = 0.98), and the ISO standard (R(2) = 0.77). Assessment of the weight change between end of inhalation and end of exhalation is a valid and simple method of measuring the water exchange performance of an HME.

  16. Compression of Born ratio for fluorescence molecular tomography/x-ray computed tomography hybrid imaging: methodology and in vivo validation.

    PubMed

    Mohajerani, Pouyan; Ntziachristos, Vasilis

    2013-07-01

    The 360° rotation geometry of the hybrid fluorescence molecular tomography/x-ray computed tomography modality allows for acquisition of very large datasets, which pose numerical limitations on the reconstruction. We propose a compression method that takes advantage of the correlation of the Born-normalized signal among sources in spatially formed clusters to reduce the size of system model. The proposed method has been validated using an ex vivo study and an in vivo study of a nude mouse with a subcutaneous 4T1 tumor, with and without inclusion of a priori anatomical information. Compression rates of up to two orders of magnitude with minimum distortion of reconstruction have been demonstrated, resulting in large reduction in weight matrix size and reconstruction time.

  17. Experimental determination of the oral bioavailability and bioaccessibility of lead particles

    PubMed Central

    2012-01-01

    In vivo estimations of Pb particle bioavailability are costly and variable, because of the nature of animal assays. The most feasible alternative for increasing the number of investigations carried out on Pb particle bioavailability is in vitro testing. This testing method requires calibration using in vivo data on an adapted animal model, so that the results will be valid for childhood exposure assessment. Also, the test results must be reproducible within and between laboratories. The Relative Bioaccessibility Leaching Procedure, which is calibrated with in vivo data on soils, presents the highest degree of validation and simplicity. This method could be applied to Pb particles, including those in paint and dust, and those in drinking water systems, which although relevant, have been poorly investigated up to now for childhood exposure assessment. PMID:23173867

  18. IN VIVO ANTI-INFLAMMATORY EFFECTS OF TARAXASTEROL AGAINST ANIMAL MODELS

    PubMed Central

    Wang, Ying; Li, Guan-Hao; Liu, Xin-Yu; Xu, Lu; Wang, Sha-Sha; Zhang, Xue-Mei

    2017-01-01

    Background: Traditional Chinese medicine Taraxacum officinale has been widely used to treat various inflammatory diseases. Taraxasterol is one of the main active components isolated from Taraxacum officinale. Recently, we have demonstrated that taraxasterol has the in vitro anti-inflammatory effects. This study aims to determine the in vivo anti-inflammatory effects of taraxasterol against animal models. Materials and Methods: Anti-inflammatory effects were assessed in four animal models by using dimethylbenzene-induced mouse ear edema, carrageenan-induced rat paw edema, acetic acid-induced mouse vascular permeability and cotton pellet-induced rat granuloma tests. Results: Our results demonstrated that taraxasterol dose-dependently attenuated dimethylbenzene-induced mouse ear edema and carrageenan-induced rat paw edema, decreased acetic acid-induced mouse vascular permeability and inhibited cotton pellet-induced rat granuloma formation. Conclusion: Our finding indicates that taraxasterol has obvious in vivo anti-inflammatory effects against animal models. It will provide experimental evidences for the traditional use of Taraxacum officinale and taraxasterol in inflammatory diseases. PMID:28480383

  19. Recent Advances in In Vivo Genotoxicity Testing: Prediction of Carcinogenic Potential Using Comet and Micronucleus Assay in Animal Models

    PubMed Central

    Kang, Seung Hun; Kwon, Jee Young; Lee, Jong Kwon; Seo, Young Rok

    2013-01-01

    Genotoxic events have been known as crucial step in the initiation of cancer. To assess the risk of cancer, genotoxicity assays, including comet, micronucleus (MN), chromosomal aberration, bacterial reverse, and sister chromatid exchange assay, can be performed. Compared with in vitro genotoxicity assay, in vivo genotoxicity assay has been used to verify in vitro assay result and definitely provide biological significance for certain organs or cell types. The comet assay can detect DNA strand breaks as markers of genotoxicity. Methods of the in vivo comet assay have been established by Japanese Center for the Validation of Alternative Methods (JaCVAM) validation studies depending on tissue and sample types. The MN can be initiated by segregation error and lagging acentric chromosome fragment. Methods of the in vivo MN assay have been established by Organization for Economic Co-operation and Development (OECD) test guidelines and many studies. Combining the in vivo comet and MN assay has been regarded as useful methodology for evaluating genetic damage, and it has been used in the assessment of potential carcinogenicity by complementarily presenting two distinct endpoints of the in vivo genotoxicity individual test. Few studies have investigated the quantitative relation between in vivo genotoxicity results and carcinogenicity. Extensive studies emphasizes that positive correlation is detectable. This review summarizes the results of the in vivo comet and MN assays that have investigated the genotoxicity of carcinogens as classified by the International Agency for Research on Cancer (IARC) carcinogenicity database. As a result, these genotoxicity data may provide meaningful information for the assessment of potential carcinogenicity and for implementation in the prevention of cancer. PMID:25337557

  20. In vivo estimation of target registration errors during augmented reality laparoscopic surgery.

    PubMed

    Thompson, Stephen; Schneider, Crispin; Bosi, Michele; Gurusamy, Kurinchi; Ourselin, Sébastien; Davidson, Brian; Hawkes, David; Clarkson, Matthew J

    2018-06-01

    Successful use of augmented reality for laparoscopic surgery requires that the surgeon has a thorough understanding of the likely accuracy of any overlay. Whilst the accuracy of such systems can be estimated in the laboratory, it is difficult to extend such methods to the in vivo clinical setting. Herein we describe a novel method that enables the surgeon to estimate in vivo errors during use. We show that the method enables quantitative evaluation of in vivo data gathered with the SmartLiver image guidance system. The SmartLiver system utilises an intuitive display to enable the surgeon to compare the positions of landmarks visible in both a projected model and in the live video stream. From this the surgeon can estimate the system accuracy when using the system to locate subsurface targets not visible in the live video. Visible landmarks may be either point or line features. We test the validity of the algorithm using an anatomically representative liver phantom, applying simulated perturbations to achieve clinically realistic overlay errors. We then apply the algorithm to in vivo data. The phantom results show that using projected errors of surface features provides a reliable predictor of subsurface target registration error for a representative human liver shape. Applying the algorithm to in vivo data gathered with the SmartLiver image-guided surgery system shows that the system is capable of accuracies around 12 mm; however, achieving this reliably remains a significant challenge. We present an in vivo quantitative evaluation of the SmartLiver image-guided surgery system, together with a validation of the evaluation algorithm. This is the first quantitative in vivo analysis of an augmented reality system for laparoscopic surgery.

  1. An in-vitro–in-vivo model for the transdermal delivery of cholecalciferol for the purposes of rodent management

    PubMed Central

    Davies, J.; Ingham, A.

    2015-01-01

    The natural selection of anticoagulant resistant rats has resulted in a need for an alternative to anticoagulant rodenticides which differs in both active ingredient and in the method of dosing. Cholecalciferol toxicity to rodents using the dermal route is demonstrated using a variety of penetration enhancing formulations in two in-vitro models and finally in-vivo. A 1 ml dose of 50/50 (v/v) DMSO/ethanol containing 15% (v/v) PEG 200 and 20% (w/v) cholecalciferol was judged as ‘sufficiently effective’ in line with the European Union’s Biocidal Products Regulation (No. 528/2012) during in-vivo studies. This dose was found to cause 100% mortality in a rat population in 64.4 h (±22 h). PMID:25835266

  2. A biomechanical approach for in vivo lung tumor motion prediction during external beam radiation therapy

    NASA Astrophysics Data System (ADS)

    Karami, Elham; Gaede, Stewart; Lee, Ting-Yim; Samani, Abbas

    2015-03-01

    Lung Cancer is the leading cause of cancer death in both men and women. Among various treatment methods currently being used in the clinic, External Beam Radiation Therapy (EBRT) is used widely not only as the primary treatment method, but also in combination with chemotherapy and surgery. However, this method may lack desirable dosimetric accuracy because of respiration induced tumor motion. Recently, biomechanical modeling of the respiratory system has become a popular approach for tumor motion prediction and compensation. This approach requires reasonably accurate data pertaining to thoracic pressure variation, diaphragm position and biomechanical properties of the lung tissue in order to predict the lung tissue deformation and tumor motion. In this paper, we present preliminary results of an in vivo study obtained from a Finite Element Model (FEM) of the lung developed to predict tumor motion during respiration.

  3. Validating CFD Predictions of Pharmaceutical Aerosol Deposition with In Vivo Data.

    PubMed

    Tian, Geng; Hindle, Michael; Lee, Sau; Longest, P Worth

    2015-10-01

    CFD provides a powerful approach to evaluate the deposition of pharmaceutical aerosols; however, previous studies have not compared CFD results of deposition throughout the lungs with in vivo data. The in vivo datasets selected for comparison with CFD predictions included fast and slow clearance of monodisperse aerosols as well as 2D gamma scintigraphy measurements for a dry powder inhaler (DPI) and softmist inhaler (SMI). The CFD model included the inhaler, a characteristic model of the mouth-throat (MT) and upper tracheobronchial (TB) airways, stochastic individual pathways (SIPs) representing the remaining TB region, and recent CFD-based correlations to predict pharmaceutical aerosol deposition in the alveolar airways. For the monodisperse aerosol, CFD predictions of total lung deposition agreed with in vivo data providing a percent relative error of 6% averaged across aerosol sizes of 1-7 μm. With the DPI and SMI, deposition was evaluated in the MT, central airways (bifurcations B1-B7), and intermediate plus peripheral airways (B8 through alveoli). Across these regions, CFD predictions produced an average relative error <10% for each inhaler. CFD simulations with the SIP modeling approach were shown to accurately predict regional deposition throughout the lungs for multiple aerosol types and different in vivo assessment methods.

  4. In-vivo NMR studies of deuterium-labeled photosensitizers in mice tumor model

    NASA Astrophysics Data System (ADS)

    Ramaprasad, Subbaraya; Liu, Y. H.; Pandey, R. K.; Shiau, Fuu-Yau; Smith, Kevin M.

    1993-06-01

    Photodynamic therapy (PDT) has emerged as a promising modality for the treatment of cancer. We are using newly synthesized and chemically defined and characterized porphyrin photosensitizers that are specifically labeled with deuterium to perform in vivo NMR studies in a murine tumor model. In vivo magnetic resonance offers the potential for repetitive, safe, noninvasive evaluation of photosensitizers, tumor metabolism, and the effect of PDT on the tumor metabolism. In an effort to monitor noninvasively the photosensitizers in an in vivo tumor model, we are synthesizing several deuterium labeled photosensitizers which absorb red light at or above 630 nm. Development of methods to test these photosensitizers directly in humans is not feasible at this time, since these photosensitizers are new and we do not yet understand the side effects. In addition, we do not understand the potential benefits compared with Photofrin II, the widely used photosensitizer. To perform our in vivo deuterium NMR studies on mouse foot tumors, we have constructed a solenoid coil which operates at 30.7 MHz for the deuterium nucleus. We have been able to detect the deuterium labeled photosensitizer in the tumor after a direct intra-tumor injection. The use of 31P NMR to predict the possible outcome of PDT in these tumors is also discussed.

  5. Deducing the Kinetics of Protein Synthesis In Vivo from the Transition Rates Measured In Vitro

    PubMed Central

    Rudorf, Sophia; Thommen, Michael; Rodnina, Marina V.; Lipowsky, Reinhard

    2014-01-01

    The molecular machinery of life relies on complex multistep processes that involve numerous individual transitions, such as molecular association and dissociation steps, chemical reactions, and mechanical movements. The corresponding transition rates can be typically measured in vitro but not in vivo. Here, we develop a general method to deduce the in-vivo rates from their in-vitro values. The method has two basic components. First, we introduce the kinetic distance, a new concept by which we can quantitatively compare the kinetics of a multistep process in different environments. The kinetic distance depends logarithmically on the transition rates and can be interpreted in terms of the underlying free energy barriers. Second, we minimize the kinetic distance between the in-vitro and the in-vivo process, imposing the constraint that the deduced rates reproduce a known global property such as the overall in-vivo speed. In order to demonstrate the predictive power of our method, we apply it to protein synthesis by ribosomes, a key process of gene expression. We describe the latter process by a codon-specific Markov model with three reaction pathways, corresponding to the initial binding of cognate, near-cognate, and non-cognate tRNA, for which we determine all individual transition rates in vitro. We then predict the in-vivo rates by the constrained minimization procedure and validate these rates by three independent sets of in-vivo data, obtained for codon-dependent translation speeds, codon-specific translation dynamics, and missense error frequencies. In all cases, we find good agreement between theory and experiment without adjusting any fit parameter. The deduced in-vivo rates lead to smaller error frequencies than the known in-vitro rates, primarily by an improved initial selection of tRNA. The method introduced here is relatively simple from a computational point of view and can be applied to any biomolecular process, for which we have detailed information about the in-vitro kinetics. PMID:25358034

  6. In Vivo Cytometry of Antigen-Specific T Cells Using 19F MRI

    PubMed Central

    Srinivas, Mangala; Turner, Michael S.; Janjic, Jelena M.; Morel, Penelope A.; Laidlaw, David H.; Ahrens, Eric T.

    2009-01-01

    Noninvasive methods to image the trafficking of phenotypically defined immune cells are paramount as we attempt to understand adaptive immunity. A 19F MRI-based methodology for tracking and quantifying cells of a defined phenotype is presented. These methods were applied to a murine inflammation model using antigen-specific T cells. The T cells that were intracellularly labeled ex vivo with a perfluoropolyether (PFPE) nanoemulsion and cells were transferred to a host receiving a localized inoculation of antigen. Longitudinal 19F MRI over 21 days revealed a dynamic accumulation and clearance of T cells in the lymph node (LN) draining the antigen. The apparent T-cell numbers were calculated in the LN from the time-lapse 19F MRI data. The effect of in vivo T-cell division on the 19F MRI cell quantification accuracy was investigated using fluorescence assays. Overall, in vivo cytometry using PFPE labeling and 19F MRI is broadly applicable to studies of whole-body cell biodistribution. PMID:19585593

  7. An imaged-based inverse finite element method to determine in-vivo mechanical properties of the human trabecular meshwork.

    PubMed

    Pant, Anup D; Kagemann, Larry; Schuman, Joel S; Sigal, Ian A; Amini, Rouzbeh

    2017-01-01

    Previous studies have shown that the trabecular meshwork (TM) is mechanically stiffer in glaucomatous eyes as compared to normal eyes. It is believed that elevated TM stiffness increases resistance to the aqueous humor outflow, producing increased intraocular pressure (IOP). It would be advantageous to measure TM mechanical properties in vivo , as these properties are believed to play an important role in the pathophysiology of glaucoma and could be useful for identifying potential risk factors. The purpose of this study was to develop a method to estimate in-vivo TM mechanical properties using clinically available exams and computer simulations. Inverse finite element simulation. A finite element model of the TM was constructed from optical coherence tomography (OCT) images of a healthy volunteer before and during IOP elevation. An axisymmetric model of the TM was then constructed. Images of the TM at a baseline IOP level of 11, and elevated level of 23 mmHg were treated as the undeformed and deformed configurations, respectively. An inverse modeling technique was subsequently used to estimate the TM shear modulus ( G ). An optimization technique was used to find the shear modulus that minimized the difference between Schlemm's canal area in the in-vivo images and simulations. Upon completion of inverse finite element modeling, the simulated area of the Schlemm's canal changed from 8,889 µm 2 to 2,088 µm 2 , similar to the experimentally measured areal change of the canal (from 8,889 µm 2 to 2,100 µm 2 ). The calculated value of shear modulus was found to be 1.93 kPa, (implying an approximate Young's modulus of 5.75 kPa), which is consistent with previous ex-vivo measurements. The combined imaging and computational simulation technique provides a unique approach to calculate the mechanical properties of the TM in vivo without any surgical intervention. Quantification of such mechanical properties will help us examine the mechanistic role of TM biomechanics in the regulation of IOP in healthy and glaucomatous eyes.

  8. Modeling limb-bud dysmorphogenesis in a predictive virtual embryo model

    EPA Science Inventory

    ToxCast is profiling the bioactivity of thousands of chemicals based on high-throughput screening (HTS) and computational methods that integrate knowledge of biological systems and in vivo toxicities (www.epa.gov/ncct/toxcast/). Many ToxCast assays assess signaling pathways and c...

  9. SU-E-QI-11: Measurement of Renal Pyruvate-To-Lactate Exchange with Hyperpolarized 13C MRI

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adamson, E; Johnson, K; Fain, S

    Purpose: Previous work [1] modeling the metabolic flux between hyperpolarized [1-13C]pyruvate and [1-13C]lactate in magnetic resonance spectroscopic imaging (MRSI) experiments failed to account for vascular signal artifacts. Here, we investigate a method to minimize the vascular signal and its impact on the fidelity of metabolic modeling. Methods: MRSI was simulated for renal metabolism in MATLAB both with and without bipolar gradients. The resulting data were fit to a two-site exchange model [1], and the effects of vascular partial volume artifacts on kinetic modeling were assessed. Bipolar gradients were then incorporated into a gradient echo sequence to validate the simulations experimentally.more » The degree of diffusion weighting (b = 32 s/mm{sup 2}) was determined empirically from 1H imaging of murine renal vascular signal. The method was then tested in vivo using MRSI with bipolar gradients following injection of hyperpolarized [1-{sup 13}C]pyruvate (∼80 mM at 20% polarization). Results: In simulations, vascular signal contaminated the renal metabolic signal at resolutions as high as 2 × 2 mm{sup 2} due to partial volume effects. The apparent exchange rate from pyruvate to lactate (k{sub p}) was underestimated in the presence of these artifacts due to contaminating pyruvate signal. Incorporation of bipolar gradients suppressed vascular signal and improved the accuracy of kp estimation. Experimentally, the in vivo results supported the ability of bipolar gradients to suppress vascular signal. The in vivo exchange rate increased, as predicted in simulations, from k{sub p} = 0.012 s-{sup 1} to k{sub p} = 0.020-{sup 1} after vascular signal suppression. Conclusion: We have demonstrated the limited accuracy of the two-site exchange model in the presence of vascular partial volume artifacts. The addition of bipolar gradients suppressed vascular signal and improved model accuracy in simulations. Bipolar gradients largely affected kp estimation in vivo. Currently, slow-flowing spins in small vessels and capillaries are only partially suppressed, so further improvement is possible. Funding support: Seed Grant from the Radiological Society of North America, GE Healthcare, University of Wisconsin Graduate School.« less

  10. Intravital imaging of a spheroid-based orthotopic model of melanoma in the mouse ear skin

    PubMed Central

    Chan, Keefe T.; Jones, Stephen W.; Brighton, Hailey E.; Bo, Tao; Cochran, Shelly D.; Sharpless, Norman E.; Bear, James E.

    2017-01-01

    Multiphoton microscopy is a powerful tool that enables the visualization of fluorescently tagged tumor cells and their stromal interactions within tissues in vivo. We have developed an orthotopic model of implanting multicellular melanoma tumor spheroids into the dermis of the mouse ear skin without the requirement for invasive surgery. Here, we demonstrate the utility of this approach to observe the primary tumor, single cell actin dynamics, and tumor-associated vasculature. These methods can be broadly applied to investigate an array of biological questions regarding tumor cell behavior in vivo. PMID:28748125

  11. Applying a Hypoxia-Incorporating TCP Model to Experimental Data on Rat Sarcoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruggieri, Ruggero, E-mail: ruggieri.ruggero@gmail.com; Stavreva, Nadejda; Naccarato, Stefania

    2012-08-01

    Purpose: To verify whether a tumor control probability (TCP) model which mechanistically incorporates acute and chronic hypoxia is able to describe animal in vivo dose-response data, exhibiting tumor reoxygenation. Methods and Materials: The investigated TCP model accounts for tumor repopulation, reoxygenation of chronic hypoxia, and fluctuating oxygenation of acute hypoxia. Using the maximum likelihood method, the model is fitted to Fischer-Moulder data on Wag/Rij rats, inoculated with rat rhabdomyosarcoma BA1112, and irradiated in vivo using different fractionation schemes. This data set is chosen because two of the experimental dose-response curves exhibit an inverse dose behavior, which is interpreted as duemore » to reoxygenation. The tested TCP model is complex, and therefore, in vivo cell survival data on the same BA1112 cell line from Reinhold were added to Fischer-Moulder data and fitted simultaneously with a corresponding cell survival function. Results: The obtained fit to the combined Fischer-Moulder-Reinhold data was statistically acceptable. The best-fit values of the model parameters for which information exists were in the range of published values. The cell survival curves of well-oxygenated and hypoxic cells, computed using the best-fit values of the radiosensitivities and the initial number of clonogens, were in good agreement with the corresponding in vitro and in situ experiments of Reinhold. The best-fit values of most of the hypoxia-related parameters were used to recompute the TCP for non-small cell lung cancer patients as a function of the number of fractions, TCP(n). Conclusions: The investigated TCP model adequately describes animal in vivo data exhibiting tumor reoxygenation. The TCP(n) curve computed for non-small cell lung cancer patients with the best-fit values of most of the hypoxia-related parameters confirms previously obtained abrupt reduction in TCP for n < 10, thus warning against the adoption of severely hypofractionated schedules.« less

  12. Modeling Fetal Alcohol Spectrum Disorder: validating an ex vivo primary hippocampal cell culture system

    PubMed Central

    Tunc-Ozcan, Elif; Ferreira, Adriana B.; Redei, Eva E.

    2016-01-01

    Background Fetal Alcohol Spectrum Disorder (FASD) is the leading non-genetic cause of mental retardation. There are no treatments for FASD to date. Preclinical in vivo and in vitro studies could help in identifying novel drug targets as for other diseases. Here, we describe an ex vivo model that combines the physiological advantages of prenatal ethanol (E) exposure in vivo with the uniformity of primary fetal hippocampal culture to characterize the effects of prenatal E. The insulin signaling pathways are known to be involved in hippocampal functions. Therefore, we compared the expression of insulin signaling pathway genes between fetal hippocampi (in vivo) and primary hippocampal culture (ex vivo). The similarity of prenatal E effects in these two paradigms would deem the ex vivo culture acceptable to screen possible treatments for FASD. Methods Pregnant Sprague-Dawley rats received one of three diets: ad libitum standard lab chow (control-C), isocaloric pair-fed (PF, nutritional control), and E containing liquid diets from gestational day (GD) 8. Fetal male and female hippocampi were collected either on GD21 (in vivo) or on GD18 for primary culture (ex vivo). Transcript levels of Igf2, Igf2r, Insr, Grb10, Rasgrf1 and Zac1 were measured by RT-qPCR. Results Hippocampal transcript levels differed by prenatal treatment in both males and females with sex differences observed in the expression of Igf2 and Insr. The effect of prenatal E on the hippocampal expression of the insulin pathway genes was parallel in the in vivo and the ex vivo conditions. Conclusions The similarity of gene expression changes in response to prenatal E between the in vivo and the ex vivo conditions ascertain that these effects are already set in the fetal hippocampus at GD18. This strengthens the feasibility of the ex vivo primary hippocampal culture as a tool to test and screen candidate drug targets for FASD. PMID:27162054

  13. The Biological Effects of Quadripolar Radiofrequency Sequential Application: A Human Experimental Study

    PubMed Central

    Cornaglia, Antonia Icaro; Faga, Angela; Scevola, Silvia

    2014-01-01

    Abstract Objective: An experimental study was conducted to assess the effectiveness and safety of an innovative quadripolar variable electrode configuration radiofrequency device with objective measurements in an ex vivo and in vivo human experimental model. Background data: Nonablative radiofrequency applications are well-established anti-ageing procedures for cosmetic skin tightening. Methods: The study was performed in two steps: ex vivo and in vivo assessments. In the ex vivo assessments the radiofrequency applications were performed on human full-thickness skin and subcutaneous tissue specimens harvested during surgery for body contouring. In the in vivo assessments the applications were performed on two volunteer patients scheduled for body contouring surgery at the end of the study. The assessment methods were: clinical examination and medical photography, temperature measurement with thermal imaging scan, and light microscopy histological examination. Results: The ex vivo assessments allowed for identification of the effective safety range for human application. The in vivo assessments allowed for demonstration of the biological effects of sequential radiofrequency applications. After a course of radiofrequency applications, the collagen fibers underwent an immediate heat-induced rearrangement and were partially denaturated and progressively metabolized by the macrophages. An overall thickening and spatial rearrangement was appreciated both in the collagen and elastic fibers, the latter displaying a juvenile reticular pattern. A late onset in the macrophage activation after sequential radiofrequency applications was appreciated. Conclusions: Our data confirm the effectiveness of sequential radiofrequency applications in obtaining attenuation of the skin wrinkles by an overall skin tightening. PMID:25244081

  14. Tracking colliding cells in vivo microscopy.

    PubMed

    Nguyen, Nhat H; Keller, Steven; Norris, Eric; Huynh, Toan T; Clemens, Mark G; Shin, Min C

    2011-08-01

    Leukocyte motion represents an important component in the innate immune response to infection. Intravital microscopy is a powerful tool as it enables in vivo imaging of leukocyte motion. Under inflammatory conditions, leukocytes may exhibit various motion behaviors, such as flowing, rolling, and adhering. With many leukocytes moving at a wide range of speeds, collisions occur. These collisions result in abrupt changes in the motion and appearance of leukocytes. Manual analysis is tedious, error prone,time consuming, and could introduce technician-related bias. Automatic tracking is also challenging due to the noise inherent in in vivo images and abrupt changes in motion and appearance due to collision. This paper presents a method to automatically track multiple cells undergoing collisions by modeling the appearance and motion for each collision state and testing collision hypotheses of possible transitions between states. The tracking results are demonstrated using in vivo intravital microscopy image sequences.We demonstrate that 1)71% of colliding cells are correctly tracked; (2) the improvement of the proposed method is enhanced when the duration of collision increases; and (3) given good detection results, the proposed method can correctly track 88% of colliding cells. The method minimizes the tracking failures under collisions and, therefore, allows more robust analysis in the study of leukocyte behaviors responding to inflammatory conditions.

  15. Validation of an in vitro model for predicting rumen and total-tract fiber digestibility in dairy cows fed corn silages with different in vitro neutral detergent fiber digestibilities at 2 levels of dry matter intake.

    PubMed

    Lopes, F; Cook, D E; Combs, D K

    2015-01-01

    An in vivo study was performed to validate an in vitro procedure that predicts rate of fiber digestion and total-tract neutral detergent fiber digestibility (TTNDFD). Two corn silages that differed in fiber digestibility were used in this trial. The corn silage with lower fiber digestibility (LFDCS) had the TTNDFD prediction of 36.0% of total NDF, whereas TTNDFD for the corn silage with higher fiber digestibility (HFDCS) was 44.9% of total neutral detergent fiber (NDF). Two diets (1 with LFDCS and 1 with HFDCS) were formulated and analyzed using the in vitro assay to predict the TTNDFD and rumen potentially digestible NDF (pdNDF) digestion rate. Similar diets were fed to 8 ruminally cannulated, multiparous, high-producing dairy cows in 2 replicated 4×4 Latin squares with 21-d periods. A 2×2 factorial arrangement of treatments was used with main effects of intake (restricted to approximately 90% of ad libitum intake vs. ad libitum) and corn silage of different fiber digestibility. Treatments were restricted and ad libitum LFDCS as well as restricted and ad libitum HFDCS. The input and output values predicted from the in vitro model were compared with in vivo measurements. The pdNDF intake predicted by the in vitro model was similar to pdNDF intake observed in vivo. Also, the pdNDF digestion rate predicted in vitro was similar to what was observed in vivo. The in vitro method predicted TTNDFD of 50.2% for HFDCS and 42.9% for LFDCS as a percentage of total NDF in the diets, whereas the in vivo measurements of TTNDFD averaged 50.3 and 48.6% of total NDF for the HFDCS and LFDCS diets, respectively. The in vitro TTNDFD assay predicted total-tract NDF digestibility of HFDCS diets similar to the digestibility observed in vivo, but for LFDCS diets the assay underestimated the digestibility compared with in vivo. When the in vitro and in vivo measurements were compared without intake effect (ad libitum and restricted) considering only diet effect of silage fiber digestibility (HFDCS and LFDCS), no differences were observed between methods. These values suggest that our in vitro TTNDFD model could be used to predicted rate of fiber digestion and NDF digestibility for dairy cattle. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  16. Longitudinal in vivo muscle function analysis of the DMSXL mouse model of myotonic dystrophy type 1.

    PubMed

    Decostre, Valérie; Vignaud, Alban; Matot, Béatrice; Huguet, Aline; Ledoux, Isabelle; Bertil, Emilie; Gjata, Bernard; Carlier, Pierre G; Gourdon, Geneviève; Hogrel, Jean-Yves

    2013-12-01

    Myotonic dystrophy is the most common adult muscle dystrophy. In view of emerging therapies, which use animal models as a proof of principle, the development of reliable outcome measures for in vivo longitudinal study of mouse skeletal muscle function is becoming crucial. To satisfy this need, we have developed a device to measure ankle dorsi- and plantarflexion torque in rodents. We present an in vivo 8-month longitudinal study of the contractile properties of the skeletal muscles of the DMSXL mouse model of myotonic dystrophy type 1. Between 4 and 12 months of age, we observed a reduction in muscle strength in the ankle dorsi- and plantarflexors of DMSXL compared to control mice although the strength per muscle cross-section was normal. Mild steady myotonia but no abnormal muscle fatigue was also observed in the DMSXL mice. Magnetic resonance imaging and histological analysis performed at the end of the study showed respectively reduced muscle cross-section area and smaller muscle fibre diameter in DMSXL mice. In conclusion, our study demonstrates the feasibility of carrying out longitudinal in vivo studies of muscle function over several months in a mouse model of myotonic dystrophy confirming the feasibility of this method to test preclinical therapeutics. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Harnessing the Potential of Human Pluripotent Stem Cells and Gene Editing for the Treatment of Retinal Degeneration.

    PubMed

    Ovando-Roche, Patrick; Georgiadis, Anastasios; Smith, Alexander J; Pearson, Rachael A; Ali, Robin R

    2017-01-01

    A major cause of visual disorders is dysfunction and/or loss of the light-sensitive cells of the retina, the photoreceptors. To develop better treatments for patients, we need to understand how inherited retinal disease mutations result in the dysfunction of photoreceptors. New advances in the field of stem cell and gene editing research offer novel ways to model retinal dystrophies in vitro and present opportunities to translate basic biological insights into therapies. This brief review will discuss some of the issues that should be taken into account when carrying out disease modelling and gene editing of retinal cells. We will discuss (i) the use of human induced pluripotent stem cells (iPSCs) for disease modelling and cell therapy; (ii) the importance of using isogenic iPSC lines as controls; (iii) CRISPR/Cas9 gene editing of iPSCs; and (iv) in vivo gene editing using AAV vectors. Ground-breaking advances in differentiation of iPSCs into retinal organoids and methods to derive mature light sensitive photoreceptors from iPSCs. Furthermore, single AAV systems for in vivo gene editing have been developed which makes retinal in vivo gene editing therapy a real prospect. Genome editing is becoming a valuable tool for disease modelling and in vivo gene editing in the retina.

  18. An in-vitro-in-vivo model for the transdermal delivery of cholecalciferol for the purposes of rodent management.

    PubMed

    Davies, J; Ingham, A

    2015-06-20

    The natural selection of anticoagulant resistant rats has resulted in a need for an alternative to anticoagulant rodenticides which differs in both active ingredient and in the method of dosing. Cholecalciferol toxicity to rodents using the dermal route is demonstrated using a variety of penetration enhancing formulations in two in-vitro models and finally in-vivo. A 1 ml dose of 50/50 (v/v) DMSO/ethanol containing 15% (v/v) PEG 200 and 20% (w/v) cholecalciferol was judged as 'sufficiently effective' in line with the European Union's Biocidal Products Regulation (No. 528/2012) during in-vivo studies. This dose was found to cause 100% mortality in a rat population in 64.4h (± 22h). Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  19. In vivo RNAi: Today and Tomorrow

    PubMed Central

    Perrimon, Norbert; Ni, Jian-Quan; Perkins, Lizabeth

    2010-01-01

    SUMMARY RNA interference (RNAi) provides a powerful reverse genetics approach to analyze gene functions both in tissue culture and in vivo. Because of its widespread applicability and effectiveness it has become an essential part of the tool box kits of model organisms such as Caenorhabditis elegans, Drosophila, and the mouse. In addition, the use of RNAi in animals in which genetic tools are either poorly developed or nonexistent enables a myriad of fundamental questions to be asked. Here, we review the methods and applications of in vivo RNAi to characterize gene functions in model organisms and discuss their impact to the study of developmental as well as evolutionary questions. Further, we discuss the applications of RNAi technologies to crop improvement, pest control and RNAi therapeutics, thus providing an appreciation of the potential for phenomenal applications of RNAi to agriculture and medicine. PMID:20534712

  20. Comparative evaluation of the efficacy of a herbal mouthwash and chlorhexidine mouthwash on select periodontal pathogens: An in vitro and ex vivo study

    PubMed Central

    Pathan, Multazim Muradkhan; Bhat, Kishore Gajanan; Joshi, Vinayak Mahableshwar

    2017-01-01

    Background: Several herbal mouthwash and herbal extracts have been tested in vitro and in vivo in search of a suitable adjunct to mechanical therapy for long-term use. In this study, we aimed to look at the antimicrobial effect of the herbal mouthwash and chlorhexidine (CHX) mouthwash on select organisms in in vitro test and an ex vivo model. Materials and Methods: The antimicrobial effects were determined against standard strains of bacteria that are involved in different stages of periodontal diseases. The in vitro tests included determination of minimum inhibitory concentration (MIC) using broth dilution and agar diffusion. In the ex vivo part of the study supragingival dental plaque were obtained from 20 periodontally healthy adult volunteers. Descriptive analysis was done for the entire quantitative and qualitative variable recorded. Results: The MIC by broth dilution method found no statistically significant difference between the mouthwashes. The agar dilution method showed CHX was more effective as compared to the herbal mouthwash against standard strains of Streptococcus mutans, Streptococcus sanguinis, and Aggregatibacter actinomycetemcomitans. However, no difference was observed between the mouthwashes for Porphyromonas, Pseudomonas aeruginosa, and Fusobacterium nucleatum. The ex vivo results conclude that none of the selected mouthwashes were statistically significantly different from each other. Conclusion: In the present study, CHX showed higher levels of antimicrobial action than the herbal mouthwash against bacterial species. The results reinforce the earlier findings that the in vitro testing is sensitive to methods and due diligence is needed when extrapolating the data for further use. However, long-term use and in vivo effectiveness against the periopathogens need to be tested in well-planned clinical trials. PMID:29456300

  1. Evaluation of anti-inflammatory potential of leaf extracts of Skimmia anquetilia

    PubMed Central

    Kumar, Vijender; Bhat, Zulfiqar Ali; Kumar, Dinesh; Khan, NA; Chashoo, IA

    2012-01-01

    Objective To evaluate anti-inflammatory potential of leaf extract of Skimmia anquetilia by in-vitro and in-vivo anti-inflammatory models. Methods Acute toxicity study was carried out to determine the toxicity level of different extract using acute toxic class method as described in Organization of Economic Co-operation and Development Guidelines No.423. Carrageenan (1% w/w) was administered and inflammation was induced in rat paw. The leaf extracts of Skimmia anquetilia were evaluated for anti-inflammatory activity by in-vitro human red blood cell (HRBC) membrane stabilization method and in-vivo carrangeenan-induced rat paw edema method. Results The in-vitro membrane stabilizing test showed petroleum ether (PE), chloroform (CE), ethyl acetate (EE), methanol (ME) and aqueous extracts (AE) showed 49.44%, 59.39%, 60.15%, 68.40% and 52.18 % protection, respectively as compared to control groups. The in-vivo results of CE, EE and ME showed 58.20%, 60.17% and 67.53% inhibition of inflammation after 6h administration of test drugs in albino rats. The potency of the leaf extracts of Skimmia anquetilia were compared with standard diclofenac (10 mg/kg) which showed 74.18% protection in in-vitro HRBC membrane stabilization test and 71.64% inhibition in in-vivo carrangeenan-induced rat paw edema model. The ME showed a dose dependent significant (P< 0.01) anti-inflammatory activity in human red blood cell membrane stabilization test and reduction of edema in carrageenan induced rat paw edema. Conclusions The present investigation has confirmed the anti-inflammatory activity of Skimmia anquetilia due to presence of bioactive phytoconstitutes for the first time and provide the pharmacological evidence in favor of traditional claim of Skimmia anquetilia as an anti- inflammatory agent. PMID:23569983

  2. Estimating in vivo airway surface liquid concentration in trials of inhaled antibiotics.

    PubMed

    Hasan, M A; Lange, C F

    2007-01-01

    Antibiotic drugs exhibit concentration dependence in their efficacy. Therefore, ensuring appropriate concentration of these drugs in the relevant body fluid is important for obtaining the desired therapeutic and physiological action. Until recently there had been no suitable method available to measure or estimate concentration of drugs in the human airways resulting from inhaled aerosols or to determine the amount of inhaled antibiotics required to ensure minimum inhibitory concentration of a drug in the airway surface liquid (ASL). In this paper a numerical method is used for estimating local concentration of inhaled pharmaceutical aerosols in different generations of the human tracheobronchial airways. The method utilizes a mathematical lung deposition model to estimate amounts of aerosols depositing in different lung generations, and a recent ASL model along with deposition results to assess the concentration of deposited drugs immediately following inhalation. Examples of concentration estimates for two case studies: one for the antibiotic tobramycin against Pseudomonas aeruginosa, and another for taurolidine against Burkholderia cepacia are presented. The aerosol characteristics, breathing pattern and properties of nebulized solutions were adopted from two recent clinical studies on efficacy of these drugs in cystic fibrosis (CF) patients and from other sources in the literature. While the clinically effective tobramycin showed a concentration higher than the required in vivo concentration, that for the ineffective taurolidine was found to be below the speculated required in vivo concentration. Results of this study thus show that the mathematical ASL model combined with the lung deposition model can be an effective tool for helping decide the optimum dosage of inhaled antibiotic drugs delivered during human clinical trials.

  3. Ki-67 staining for determination of rhesus macaque T cell proliferative responses ex vivo1

    PubMed Central

    Shedlock, Devon J.; Talbott, Kendra T.; Morrow, Matthew P.; Ferraro, Bernadette; Hokey, David A.; Muthumani, Karuppiah; Weiner, David B.

    2010-01-01

    The capacity for robust proliferation upon re-infection is a hallmark of adaptive immunity and the basis of vaccination. A widely used animal model for the study of human disease is the rhesus macaque (RM), where capacity for proliferation can be assessed ex vivo using carboxyfluorescein succinimidyl ester (CFSE)-based dilution assays. However, we show over the course of the standard ex vivo proliferation assay that CFSE-labeling at commonly-used dye concentrations induces significant cell death, but that this phenomenon is dose-dependent. Here we describe an alternative, semi-quantitative method for estimating T cell proliferative responses that avoids the putative biases associated with chemical modification. RM peripheral blood mononuclear cells were stimulated ex vivo with cognate peptides for five days, immunostained for intracellular Ki-67, and then analyzed by flow cytometry. We describe a gating strategy using Ki-67 and side light scatter, also a marker of blastogenesis, which correlates strongly with data from CFSE dilution. We show that this method is a valid tool for measuring RM antigen-specific cellular proliferation ex vivo and can be used as an alternative to CFSE dilution assays. PMID:20104580

  4. Accuracy of Monte Carlo simulations compared to in-vivo MDCT dosimetry.

    PubMed

    Bostani, Maryam; Mueller, Jonathon W; McMillan, Kyle; Cody, Dianna D; Cagnon, Chris H; DeMarco, John J; McNitt-Gray, Michael F

    2015-02-01

    The purpose of this study was to assess the accuracy of a Monte Carlo simulation-based method for estimating radiation dose from multidetector computed tomography (MDCT) by comparing simulated doses in ten patients to in-vivo dose measurements. MD Anderson Cancer Center Institutional Review Board approved the acquisition of in-vivo rectal dose measurements in a pilot study of ten patients undergoing virtual colonoscopy. The dose measurements were obtained by affixing TLD capsules to the inner lumen of rectal catheters. Voxelized patient models were generated from the MDCT images of the ten patients, and the dose to the TLD for all exposures was estimated using Monte Carlo based simulations. The Monte Carlo simulation results were compared to the in-vivo dose measurements to determine accuracy. The calculated mean percent difference between TLD measurements and Monte Carlo simulations was -4.9% with standard deviation of 8.7% and a range of -22.7% to 5.7%. The results of this study demonstrate very good agreement between simulated and measured doses in-vivo. Taken together with previous validation efforts, this work demonstrates that the Monte Carlo simulation methods can provide accurate estimates of radiation dose in patients undergoing CT examinations.

  5. Topical ketoprofen nanogel: artificial neural network optimization, clustered bootstrap validation, and in vivo activity evaluation based on longitudinal dose response modeling.

    PubMed

    Elkomy, Mohammed H; Elmenshawe, Shahira F; Eid, Hussein M; Ali, Ahmed M A

    2016-11-01

    This work aimed at investigating the potential of solid lipid nanoparticles (SLN) as carriers for topical delivery of Ketoprofen (KP); evaluating a novel technique incorporating Artificial Neural Network (ANN) and clustered bootstrap for optimization of KP-loaded SLN (KP-SLN); and demonstrating a longitudinal dose response (LDR) modeling-based approach to compare the activity of topical non-steroidal anti-inflammatory drug formulations. KP-SLN was fabricated by a modified emulsion/solvent evaporation method. Box-Behnken design was implemented to study the influence of glycerylpalmitostearate-to-KP ratio, Tween 80, and lecithin concentrations on particle size, entrapment efficiency, and amount of drug permeated through rat skin in 24 hours. Following clustered bootstrap ANN optimization, the optimized KP-SLN was incorporated into an aqueous gel and evaluated for rheology, in vitro release, permeability, skin irritation and in vivo activity using carrageenan-induced rat paw edema model and LDR mathematical model to analyze the time course of anti-inflammatory effect at various application durations. Lipid-to-drug ratio of 7.85 [bootstrap 95%CI: 7.63-8.51], Tween 80 of 1.27% [bootstrap 95%CI: 0.601-2.40%], and Lecithin of 0.263% [bootstrap 95%CI: 0.263-0.328%] were predicted to produce optimal characteristics. Compared with profenid® gel, the optimized KP-SLN gel exhibited slower release, faster permeability, better texture properties, greater efficacy, and similar potency. SLNs are safe and effective permeation enhancers. ANN coupled with clustered bootstrap is a useful method for finding optimal solutions and estimating uncertainty associated with them. LDR models allow mechanistic understanding of comparative in vivo performances of different topical formulations, and help design efficient dermatological bioequivalence assessment methods.

  6. A comparison of quantitative methods for clinical imaging with hyperpolarized (13)C-pyruvate.

    PubMed

    Daniels, Charlie J; McLean, Mary A; Schulte, Rolf F; Robb, Fraser J; Gill, Andrew B; McGlashan, Nicholas; Graves, Martin J; Schwaiger, Markus; Lomas, David J; Brindle, Kevin M; Gallagher, Ferdia A

    2016-04-01

    Dissolution dynamic nuclear polarization (DNP) enables the metabolism of hyperpolarized (13)C-labelled molecules, such as the conversion of [1-(13)C]pyruvate to [1-(13)C]lactate, to be dynamically and non-invasively imaged in tissue. Imaging of this exchange reaction in animal models has been shown to detect early treatment response and correlate with tumour grade. The first human DNP study has recently been completed, and, for widespread clinical translation, simple and reliable methods are necessary to accurately probe the reaction in patients. However, there is currently no consensus on the most appropriate method to quantify this exchange reaction. In this study, an in vitro system was used to compare several kinetic models, as well as simple model-free methods. Experiments were performed using a clinical hyperpolarizer, a human 3 T MR system, and spectroscopic imaging sequences. The quantitative methods were compared in vivo by using subcutaneous breast tumours in rats to examine the effect of pyruvate inflow. The two-way kinetic model was the most accurate method for characterizing the exchange reaction in vitro, and the incorporation of a Heaviside step inflow profile was best able to describe the in vivo data. The lactate time-to-peak and the lactate-to-pyruvate area under the curve ratio were simple model-free approaches that accurately represented the full reaction, with the time-to-peak method performing indistinguishably from the best kinetic model. Finally, extracting data from a single pixel was a robust and reliable surrogate of the whole region of interest. This work has identified appropriate quantitative methods for future work in the analysis of human hyperpolarized (13)C data. © 2016 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.

  7. In Vitro and In Vivo Synergy of the Oxadiazole Class of Antibacterials with β-Lactams.

    PubMed

    Janardhanan, Jeshina; Meisel, Jayda E; Ding, Derong; Schroeder, Valerie A; Wolter, William R; Mobashery, Shahriar; Chang, Mayland

    2016-09-01

    The oxadiazole antibacterials target the bacterial cell wall and are bactericidal. We investigated the synergism of ND-421 with the commonly used β-lactams and non-β-lactam antibiotics by the checkerboard method and by time-kill assays. ND-421 synergizes well with β-lactam antibiotics, and it also exhibits a long postantibiotic effect (4.7 h). We also evaluated the in vivo efficacy of ND-421 in a murine neutropenic thigh infection model alone and in combination with oxacillin. ND-421 has in vivo efficacy by itself in a clinically relevant infection model (1.49 log10 bacterial reduction for ND-321 versus 0.36 log10 for linezolid with NRS119) and acts synergistically with β-lactam antibiotics in vitro and in vivo, and the combination of ND-421 with oxacillin is efficacious in a mouse neutropenic thigh methicillin-resistant Staphylococcus aureus (MRSA) infection model (1.60 log10 bacterial reduction). The activity of oxacillin was potentiated in the presence of ND-421, as the strain would have been resistant to oxacillin otherwise. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  8. Lentiviral vector-mediated genetic modification of human neural progenitor cells for ex vivo gene therapy.

    PubMed

    Capowski, Elizabeth E; Schneider, Bernard L; Ebert, Allison D; Seehus, Corey R; Szulc, Jolanta; Zufferey, Romain; Aebischer, Patrick; Svendsen, Clive N

    2007-07-30

    Human neural progenitor cells (hNPC) hold great potential as an ex vivo system for delivery of therapeutic proteins to the central nervous system. When cultured as aggregates, termed neurospheres, hNPC are capable of significant in vitro expansion. In the current study, we present a robust method for lentiviral vector-mediated gene delivery into hNPC that maintains the differentiation and proliferative properties of neurosphere cultures while minimizing the amount of viral vector used and controlling the number of insertion sites per population. This method results in long-term, stable expression even after differentiation of the hNPC to neurons and astrocytes and allows for generation of equivalent transgenic populations of hNPC. In addition, the in vitro analysis presented predicts the behavior of transgenic lines in vivo when transplanted into a rodent model of Parkinson's disease. The methods presented provide a powerful tool for assessing the impact of factors such as promoter systems or different transgenes on the therapeutic utility of these cells.

  9. Pulsed and oscillating gradient MRI for assessment of cell size and Extracellular space (POMACE) in mouse gliomas

    PubMed Central

    Reynaud, Olivier; Winters, Kerryanne Veronica; Hoang, Dung Minh; Wadghiri, Youssef Zaim; Novikov, Dmitry S.; Kim, Sungheon Gene

    2016-01-01

    Solid tumor microstructure is related to aggressiveness of tumor, interstitial pressure and drug delivery pathways that are closely associated with treatment response, metastatic spread and prognosis. In this study, we introduce a novel diffusion MRI data analysis framework, Pulsed and Oscillating gradient MRI for Assessment of Cell size and Extracellular space (POMACE), and demonstrate its feasibility in a mouse tumor model. In vivo and ex vivo POMACE experiments were performed on mice bearing the GL261 murine glioma model (n=8). Since the complete diffusion time-dependence is in general non-analytical, the tumor microstructure was modeled in an appropriate time/frequency regime by impermeable spheres (radius Rcell, intracellular diffusivity Dics) surrounded by extracellular space (approximated by constant apparent diffusivity Decs in volume fraction ECS). POMACE parametric maps (ECS, Rcell, Dics, Decs) were compared with conventional diffusion weighted imaging metrics, electron microscopy (EM), alternative ECS determination based on effective medium theory (EMT), and optical microscopy performed on the same samples. It was shown that Decs can be approximated by its long-time tortuosity limit in the range [1/(88 Hz) - 31 ms]. ECS estimations (44±7% in vivo and 54±11% ex vivo) were in agreement with EMT-based ECS and literature on brain gliomas. Ex vivo, ECS maps correlated well with optical microscopy. Cell sizes (Rcell=4.8±1.3 in vivo and 4.3±1.4 μm ex vivo) were consistent with EM measurements (4.7±1.8 μm). In conclusion, Rcell and ECS can be quantified and mapped in vivo and ex vivo in brain tumors using the proposed POMACE method. Our experimental results support that POMACE provides a way to interpret the frequency- or time-dependence of the diffusion coefficient in tumors in terms of objective biophysical parameters of neuronal tissue, which can be used for non-invasive monitoring of preclinical cancer studies and treatment efficacy. PMID:27448059

  10. Stress analysis of irradiated human tooth enamel using finite element methods

    PubMed Central

    Thiagarajan, Ganesh; Vizcarra, Bruno; Bodapudi, Venkata; Reed, Rachel; Seyedmahmoud, Rasoul; Wang, Yong; Gorski, Jeffrey P.; Walker, Mary P.

    2017-01-01

    The objectives of this project were to use finite element methods to determine how changes in the elastic modulus due to oral cancer therapeutic radiation alter the distribution of mechanical stresses in teeth and to determine if observed failures in irradiated teeth correlate with changes in mechanical stresses. A thin slice section finite element (FE) model was constructed from micro CT sections of a molar tooth using MIMICS and 3-Matic software. This model divides the tooth into three enamel regions, the dentin-enamel junction (DEJ) and dentin. The enamel elastic modulus was determined in each region using nano indentation for three experimental groups namely – control (non-radiated), in vitro irradiated (simulated radiotherapy following tooth extraction) and in vivo irradiated (extracted subsequent to oral cancer patient radiotherapy) teeth. Physiological loads were applied to the tooth models at the buccal and lingual cusp regions for all three groups (control, in vitro and in vivo). The principal tensile stress and the maximum shear stress were used to compare the results from different groups since it has been observed in previous studies that delamination of enamel from the underlying dentin was one of the major reasons for the failure of teeth following therapeutic radiation. From the FE data, we observed an increase in the principal tensile stress within the inner enamel region of in vivo irradiated teeth (9.97 ± 1.32 MPa) as compared to control/non-irradiated teeth (8.44 ± 1.57 MPa). Our model predicts that failure occurs at the inner enamel/DEJ interface due to extremely high tensile and maximum shear stresses in in vivo irradiated teeth which could be a cause of enamel delamination due to radiotherapy. PMID:29063816

  11. Stress analysis of irradiated human tooth enamel using finite element methods.

    PubMed

    Thiagarajan, Ganesh; Vizcarra, Bruno; Bodapudi, Venkata; Reed, Rachel; Seyedmahmoud, Rasoul; Wang, Yong; Gorski, Jeffrey P; Walker, Mary P

    2017-11-01

    The objectives of this project were to use finite element methods to determine how changes in the elastic modulus due to oral cancer therapeutic radiation alter the distribution of mechanical stresses in teeth and to determine if observed failures in irradiated teeth correlate with changes in mechanical stresses. A thin slice section finite element (FE) model was constructed from micro CT sections of a molar tooth using MIMICS and 3-Matic software. This model divides the tooth into three enamel regions, the dentin-enamel junction (DEJ) and dentin. The enamel elastic modulus was determined in each region using nano indentation for three experimental groups namely - control (non-radiated), in vitro irradiated (simulated radiotherapy following tooth extraction) and in vivo irradiated (extracted subsequent to oral cancer patient radiotherapy) teeth. Physiological loads were applied to the tooth models at the buccal and lingual cusp regions for all three groups (control, in vitro and in vivo). The principal tensile stress and the maximum shear stress were used to compare the results from different groups since it has been observed in previous studies that delamination of enamel from the underlying dentin was one of the major reasons for the failure of teeth following therapeutic radiation. From the FE data, we observed an increase in the principal tensile stress within the inner enamel region of in vivo irradiated teeth (9.97 ± 1.32 MPa) as compared to control/non-irradiated teeth (8.44 ± 1.57 MPa). Our model predicts that failure occurs at the inner enamel/DEJ interface due to extremely high tensile and maximum shear stresses in in vivo irradiated teeth which could be a cause of enamel delamination due to radiotherapy.

  12. Can conclusions drawn from phantom-based image noise assessments be generalized to in vivo studies for the nonlinear model-based iterative reconstruction method?

    PubMed Central

    Gomez-Cardona, Daniel; Li, Ke; Hsieh, Jiang; Lubner, Meghan G.; Pickhardt, Perry J.; Chen, Guang-Hong

    2016-01-01

    Purpose: Phantom-based objective image quality assessment methods are widely used in the medical physics community. For a filtered backprojection (FBP) reconstruction-based linear or quasilinear imaging system, the use of this methodology is well justified. Many key image quality metrics acquired with phantom studies can be directly applied to in vivo human subject studies. Recently, a variety of image quality metrics have been investigated for model-based iterative image reconstruction (MBIR) methods and several novel characteristics have been discovered in phantom studies. However, the following question remains unanswered: can certain results obtained from phantom studies be generalized to in vivo animal studies and human subject studies? The purpose of this paper is to address this question. Methods: One of the most striking results obtained from phantom studies is a novel power-law relationship between noise variance of MBIR (σ2) and tube current-rotation time product (mAs): σ2 ∝ (mAs)−0.4 [K. Li et al., “Statistical model based iterative reconstruction (MBIR) in clinical CT systems: Experimental assessment of noise performance,” Med. Phys. 41, 041906 (15pp.) (2014)]. To examine whether the same power-law works for in vivo cases, experimental data from two types of in vivo studies were analyzed in this paper. All scans were performed with a 64-slice diagnostic CT scanner (Discovery CT750 HD, GE Healthcare) and reconstructed with both FBP and a MBIR method (Veo, GE Healthcare). An Institutional Animal Care and Use Committee-approved in vivo animal study was performed with an adult swine at six mAs levels (10–290). Additionally, human subject data (a total of 110 subjects) acquired from an IRB-approved clinical trial were analyzed. In this clinical trial, a reduced-mAs scan was performed immediately following the standard mAs scan; the specific mAs used for the two scans varied across human subjects and were determined based on patient size and clinical indications. The measurements of σ2 were performed at different mAs by drawing regions-of-interest (ROIs) in the liver and the subcutaneous fat. By applying a linear least-squares regression, the β values in the power-law relationship σ2 ∝ (mAs)−β were measured for the in vivo data and compared with the value found in phantom experiments. Results: For the in vivo swine study, an exponent of β = 0.43 was found for MBIR, and the coefficient of determination (R2) for the corresponding least-squares power-law regression was 0.971. As a reference, the β and R2 values for FBP were found to be 0.98 and 0.997, respectively, from the same study, which are consistent with the well-known σ2 ∝ (mAs)−1.0 relationship for linear CT systems. For the human subject study, the measured β values for the MBIR images were 0.41 ± 0.12 in the liver and 0.37 ± 0.12 in subcutaneous fat. In comparison, the β values for the FBP images were 1.04 ± 0.10 in the liver and 0.97 ± 0.12 in subcutaneous fat. The β values of MBIR and FBP obtained from the in vivo studies were found to be statistically equivalent to the corresponding β values from the phantom study within an equivalency interval of [ − 0.1, 0.1] (p < 0.05); across MBIR and FBP, the difference in β was statistically significant (p < 0.05). Conclusions: Despite the nonlinear nature of the MBIR method, the power-law relationship, σ2 ∝ (mAs)−0.4, found from phantom studies can be applied to in vivo animal and human subject studies. PMID:26843232

  13. Finite element method simulating temperature distribution in skin induced by 980-nm pulsed laser based on pain stimulation.

    PubMed

    Wang, Han; Dong, Xiao-Xi; Yang, Ji-Chun; Huang, He; Li, Ying-Xin; Zhang, Hai-Xia

    2017-07-01

    For predicting the temperature distribution within skin tissue in 980-nm laser-evoked potentials (LEPs) experiments, a five-layer finite element model (FEM-5) was constructed based on Pennes bio-heat conduction equation and the Lambert-Beer law. The prediction results of the FEM-5 model were verified by ex vivo pig skin and in vivo rat experiments. Thirty ex vivo pig skin samples were used to verify the temperature distribution predicted by the model. The output energy of the laser was 1.8, 3, and 4.4 J. The laser spot radius was 1 mm. The experiment time was 30 s. The laser stimulated the surface of the ex vivo pig skin beginning at 10 s and lasted for 40 ms. A thermocouple thermometer was used to measure the temperature of the surface and internal layers of the ex vivo pig skin, and the sampling frequency was set to 60 Hz. For the in vivo experiments, nine adult male Wistar rats weighing 180 ± 10 g were used to verify the prediction results of the model by tail-flick latency. The output energy of the laser was 1.4 and 2.08 J. The pulsed width was 40 ms. The laser spot radius was 1 mm. The Pearson product-moment correlation and Kruskal-Wallis test were used to analyze the correlation and the difference of data. The results of all experiments showed that the measured and predicted data had no significant difference (P > 0.05) and good correlation (r > 0.9). The safe laser output energy range (1.8-3 J) was also predicted. Using the FEM-5 model prediction, the effective pain depth could be accurately controlled, and the nociceptors could be selectively activated. The FEM-5 model can be extended to guide experimental research and clinical applications for humans.

  14. Comparative assessment of three standardized robotic surgery training methods.

    PubMed

    Hung, Andrew J; Jayaratna, Isuru S; Teruya, Kara; Desai, Mihir M; Gill, Inderbir S; Goh, Alvin C

    2013-10-01

    To evaluate three standardized robotic surgery training methods, inanimate, virtual reality and in vivo, for their construct validity. To explore the concept of cross-method validity, where the relative performance of each method is compared. Robotic surgical skills were prospectively assessed in 49 participating surgeons who were classified as follows: 'novice/trainee': urology residents, previous experience <30 cases (n = 38) and 'experts': faculty surgeons, previous experience ≥30 cases (n = 11). Three standardized, validated training methods were used: (i) structured inanimate tasks; (ii) virtual reality exercises on the da Vinci Skills Simulator (Intuitive Surgical, Sunnyvale, CA, USA); and (iii) a standardized robotic surgical task in a live porcine model with performance graded by the Global Evaluative Assessment of Robotic Skills (GEARS) tool. A Kruskal-Wallis test was used to evaluate performance differences between novices and experts (construct validity). Spearman's correlation coefficient (ρ) was used to measure the association of performance across inanimate, simulation and in vivo methods (cross-method validity). Novice and expert surgeons had previously performed a median (range) of 0 (0-20) and 300 (30-2000) robotic cases, respectively (P < 0.001). Construct validity: experts consistently outperformed residents with all three methods (P < 0.001). Cross-method validity: overall performance of inanimate tasks significantly correlated with virtual reality robotic performance (ρ = -0.7, P < 0.001) and in vivo robotic performance based on GEARS (ρ = -0.8, P < 0.0001). Virtual reality performance and in vivo tissue performance were also found to be strongly correlated (ρ = 0.6, P < 0.001). We propose the novel concept of cross-method validity, which may provide a method of evaluating the relative value of various forms of skills education and assessment. We externally confirmed the construct validity of each featured training tool. © 2013 BJU International.

  15. In vivo imaging of prodromal hippocampus CA1 subfield oxidative stress in models of Alzheimer disease and Angelman syndrome.

    PubMed

    Berkowitz, Bruce A; Lenning, Jacob; Khetarpal, Nikita; Tran, Catherine; Wu, Johnny Y; Berri, Ali M; Dernay, Kristin; Haacke, E Mark; Shafie-Khorassani, Fatema; Podolsky, Robert H; Gant, John C; Maimaiti, Shaniya; Thibault, Olivier; Murphy, Geoffrey G; Bennett, Brian M; Roberts, Robin

    2017-09-01

    Hippocampus oxidative stress is considered pathogenic in neurodegenerative diseases, such as Alzheimer disease (AD), and in neurodevelopmental disorders, such as Angelman syndrome (AS). Yet clinical benefits of antioxidant treatment for these diseases remain unclear because conventional imaging methods are unable to guide management of therapies in specific hippocampus subfields in vivo that underlie abnormal behavior. Excessive production of paramagnetic free radicals in nonhippocampus brain tissue can be measured in vivo as a greater-than-normal 1/ T 1 that is quenchable with antioxidant as measured by quench-assisted (Quest) MRI. Here, we further test this approach in phantoms, and we present proof-of-concept data in models of AD-like and AS hippocampus oxidative stress that also exhibit impaired spatial learning and memory. AD-like models showed an abnormal gradient along the CA1 dorsal-ventral axis of excessive free radical production as measured by Quest MRI, and redox-sensitive calcium dysregulation as measured by manganese-enhanced MRI and electrophysiology. In the AS model, abnormally high free radical levels were observed in dorsal and ventral CA1. Quest MRI is a promising in vivo paradigm for bridging brain subfield oxidative stress and behavior in animal models and in human patients to better manage antioxidant therapy in devastating neurodegenerative and neurodevelopmental diseases.-Berkowitz, B. A., Lenning, J., Khetarpal, N., Tran, C., Wu, J. Y., Berri, A. M., Dernay, K., Haacke, E. M., Shafie-Khorassani, F., Podolsky, R. H., Gant, J. C., Maimaiti, S., Thibault, O., Murphy, G. G., Bennett, B. M., Roberts, R. In vivo imaging of prodromal hippocampus CA1 subfield oxidative stress in models of Alzheimer disease and Angelman syndrome. © FASEB.

  16. Dissolution DNP for in vivo preclinical studies

    NASA Astrophysics Data System (ADS)

    Comment, Arnaud

    2016-03-01

    The tremendous polarization enhancement afforded by dissolution dynamic nuclear polarization (DNP) can be taken advantage of to perform preclinical in vivo molecular and metabolic imaging. Following the injection of molecules that are hyperpolarized via dissolution DNP, real-time measurements of their biodistribution and metabolic conversion can be recorded. This technology therefore provides a unique and invaluable tool for probing cellular metabolism in vivo in animal models in a noninvasive manner. It gives the opportunity to follow and evaluate disease progression and treatment response without requiring ex vivo destructive tissue assays. Although its considerable potential has now been widely recognized, hyperpolarized magnetic resonance by dissolution DNP remains a challenging method to implement for routine in vivo preclinical measurements. The aim of this article is to provide an overview of the current state-of-the-art technology for preclinical applications and the challenges that need to be addressed to promote it and allow its wider dissemination in the near future.

  17. Review of Modelling Techniques for In Vivo Muscle Force Estimation in the Lower Extremities during Strength Training

    PubMed Central

    Schellenberg, Florian; Oberhofer, Katja; Taylor, William R.

    2015-01-01

    Background. Knowledge of the musculoskeletal loading conditions during strength training is essential for performance monitoring, injury prevention, rehabilitation, and training design. However, measuring muscle forces during exercise performance as a primary determinant of training efficacy and safety has remained challenging. Methods. In this paper we review existing computational techniques to determine muscle forces in the lower limbs during strength exercises in vivo and discuss their potential for uptake into sports training and rehabilitation. Results. Muscle forces during exercise performance have almost exclusively been analysed using so-called forward dynamics simulations, inverse dynamics techniques, or alternative methods. Musculoskeletal models based on forward dynamics analyses have led to considerable new insights into muscular coordination, strength, and power during dynamic ballistic movement activities, resulting in, for example, improved techniques for optimal performance of the squat jump, while quasi-static inverse dynamics optimisation and EMG-driven modelling have helped to provide an understanding of low-speed exercises. Conclusion. The present review introduces the different computational techniques and outlines their advantages and disadvantages for the informed usage by nonexperts. With sufficient validation and widespread application, muscle force calculations during strength exercises in vivo are expected to provide biomechanically based evidence for clinicians and therapists to evaluate and improve training guidelines. PMID:26417378

  18. Modeling growth and dissemination of lymphoma in a co-evolving lymph node: a diffuse-domain approach

    NASA Astrophysics Data System (ADS)

    Chuang, Yao-Li; Cristini, Vittorio; Chen, Ying; Li, Xiangrong; Frieboes, Hermann; Lowengrub, John

    2013-03-01

    While partial differential equation models of tumor growth have successfully described various spatiotemporal phenomena observed for in-vitro tumor spheroid experiments, one challenge towards taking these models to further study in-vivo tumors is that instead of relatively static tissue culture with regular boundary conditions, in-vivo tumors are often confined in organ tissues that co-evolve with the tumor growth. Here we adopt a recently developed diffuse-domain method to account for the co-evolving domain boundaries, adapting our previous in-vitro tumor model for the development of lymphoma encapsulated in a lymph node, which may swell or shrink due to proliferation and dissemination of lymphoma cells and treatment by chemotherapy. We use the model to study the induced spatial heterogeneity, which may arise as an emerging phenomenon in experimental observations and model analysis. Spatial heterogeneity is believed to lead to tumor infiltration patterns and reduce the efficacy of chemotherapy, leaving residuals that cause cancer relapse after the treatment. Understanding the spatiotemporal evolution of in-vivo tumors can be an essential step towards more effective strategies of curing cancer. Supported by NIH-PSOC grant 1U54CA143907-01.

  19. Bone compositional study during healing of subcritical calvarial defects in rats by Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Ahmed, Rafay; Wing Lun Law, Alan; Cheung, Tsz Wing; Lau, Condon

    2017-07-01

    Subcritical calvarial defects are important to study bone regeneration during healing. In this study 1mm calvarial defects were created using trephine in the parietal bones of Sprague-Dawley rats (n=7) that served as in vivo defects. Subjects were sacrificed after 7 days and the additional defects were created on the harvested skull with the same method to serve as control defects. Raman spectroscopy is established to investigate mineral/matrix ratio, carbonate/phosphate ratio and crystallinity of three different surfaces; in vivo defects, control defects and normal surface. Results show 21% and 23% decrease in mineral/matrix after 7 days of healing from surface to in vivo and control to in vivo defects, respectively. Carbonate to phosphate ratio was found to be increased by 39% while crystallinity decreased by 26% in both surface to in vivo and control to in vivo defects. This model allows to study the regenerated bone without mechanically perturbing healing surface.

  20. FMT-XCT: in vivo animal studies with hybrid fluorescence molecular tomography-X-ray computed tomography.

    PubMed

    Ale, Angelique; Ermolayev, Vladimir; Herzog, Eva; Cohrs, Christian; de Angelis, Martin Hrabé; Ntziachristos, Vasilis

    2012-06-01

    The development of hybrid optical tomography methods to improve imaging performance has been suggested over a decade ago and has been experimentally demonstrated in animals and humans. Here we examined in vivo performance of a camera-based hybrid fluorescence molecular tomography (FMT) system for 360° imaging combined with X-ray computed tomography (XCT). Offering an accurately co-registered, information-rich hybrid data set, FMT-XCT has new imaging possibilities compared to stand-alone FMT and XCT. We applied FMT-XCT to a subcutaneous 4T1 tumor mouse model, an Aga2 osteogenesis imperfecta model and a Kras lung cancer mouse model, using XCT information during FMT inversion. We validated in vivo imaging results against post-mortem planar fluorescence images of cryoslices and histology data. Besides offering concurrent anatomical and functional information, FMT-XCT resulted in the most accurate FMT performance to date. These findings indicate that addition of FMT optics into the XCT gantry may be a potent upgrade for small-animal XCT systems.

  1. Life-Stage Physiologically-Based Pharmacokinetic (PBPK) Model Applications to Screen Environmental Hazards.

    EPA Science Inventory

    This presentation discusses methods used to extrapolate from in vitro high-throughput screening (HTS) toxicity data for an endocrine pathway to in vivo for early life stages in humans, and the use of a life stage PBPK model to address rapidly changing physiological parameters. A...

  2. New Methods in Tissue Engineering: Improved Models for Viral Infection.

    PubMed

    Ramanan, Vyas; Scull, Margaret A; Sheahan, Timothy P; Rice, Charles M; Bhatia, Sangeeta N

    2014-11-01

    New insights in the study of virus and host biology in the context of viral infection are made possible by the development of model systems that faithfully recapitulate the in vivo viral life cycle. Standard tissue culture models lack critical emergent properties driven by cellular organization and in vivo-like function, whereas animal models suffer from limited susceptibility to relevant human viruses and make it difficult to perform detailed molecular manipulation and analysis. Tissue engineering techniques may enable virologists to create infection models that combine the facile manipulation and readouts of tissue culture with the virus-relevant complexity of animal models. Here, we review the state of the art in tissue engineering and describe how tissue engineering techniques may alleviate some common shortcomings of existing models of viral infection, with a particular emphasis on hepatotropic viruses. We then discuss possible future applications of tissue engineering to virology, including current challenges and potential solutions.

  3. In vivo transgenic bioassays and assessment of the carcinogenic potential of pharmaceuticals.

    PubMed Central

    Contrera, J F; DeGeorge, J J

    1998-01-01

    There is general agreement in the scientific community on the need to improve carcinogenicity testing and the assessment of human carcinogenic risk and to incorporate more information on mechanisms and modes of action into the risk assessment process. Advances in molecular biology have identified a growing number of genes such as protooncogenes and tumor-suppressor genes that are highly conserved across species and are associated with a wide variety of human and animal cancers. In vivo transgenic rodent models incorporating such mechanisms are used to identify mechanisms involved in tumor formation and as selective tests for carcinogens. Transgenic methods can be considered an extension of genetic manipulation by selective breeding, which long has been employed in science and agriculture. The use of two rodent species in carcinogenicity testing is especially important for identifying transspecies carcinogens. The capacity of a substance to induce neoplasia across species suggests that the mechanism(s) involved in the induction of the neoplasia are conserved and therefore may have significance for humans. Based on available information there is sufficient experience with some in vivo transgenic rodent carcinogenicity models to support their application as complementary second species studies in conjunction with a single 2-year rodent carcinogenicity study. The optional substitution of a second 2-year rodent carcinogenicity study with an alternative study such as an in vivo transgenic carcinogenicity study is part of the International Conference on Harmonization guidance S1B: Testing for Carcinogenicity of Pharmaceuticals. This guidance is intended to be flexible enough to accommodate a wide range of possible carcinogenicity assessment models currently under consideration or models that may be developed in the future. The use of an in vivo transgenic mouse model in place of a second 2-year mouse study will improve the assessment of carcinogenic risk by contributing insights into the mechanisms of tumorigenesis and potential human relevance not available from a standard 2-year bioassay. It is envisioned that this will stimulate the further development of more efficient and relevant methods for identifying and assessing potential human carcinogenic risk, which will benefit public health. PMID:9539006

  4. Modeling breath-enhanced jet nebulizers to estimate pulmonary drug deposition.

    PubMed

    Wee, Wallace B; Leung, Kitty; Coates, Allan L

    2013-12-01

    Predictable delivery of aerosol medication for a given patient and drug-device combination is crucial, both for therapeutic effect and to avoid toxicity. The gold standard for measuring pulmonary drug deposition (PDD) is gamma scintigraphy. However, these techniques expose patients to radiation, are complicated, and are relevant for only one patient and drug-device combination, making them less available. Alternatively, in vitro experiments have been used as a surrogate to estimate in vivo performance, but this is time-consuming and has few "in vitro to in vivo" correlations for therapeutics delivered by inhalation. An alternative method for determining inhaled mass and PDD is proposed by deriving and validating a mathematical model, for the individual breathing patterns of normal subjects and drug-device operating parameters. This model was evaluated for patients with cystic fibrosis (CF). This study is comprised of three stages: mathematical model derivation, in vitro testing, and in vivo validation. The model was derived from an idealized patient's respiration cycle and the steady-state operating characteristics of a drug-device combination. The model was tested under in vitro dynamic conditions that varied tidal volume, inspiration-to-expiration time, and breaths per minute. This approach was then extended to incorporate additional physiological parameters (dead space, aerodynamic particle size distribution) and validated against in vivo nuclear medicine data in predicting PDD in both normal subjects and those with CF. The model shows strong agreement with in vitro testing. In vivo testing with normal subjects yielded good agreement, but less agreement for patients with chronic obstructive lung disease and bronchiectasis from CF. The mathematical model was successful in accommodating a wide range of breathing patterns and drug-device combinations. Furthermore, the model has demonstrated its effectiveness in predicting the amount of aerosol delivered to "normal" subjects. However, challenges remain in predicting deposition in obstructive lung disease.

  5. Monitoring Molecules in Neuroscience Then and Now

    PubMed Central

    Rice, Margaret E.

    2017-01-01

    The 16th International Conference on Monitoring Molecules in Neuroscience (MMiN) was held in Gothenburg, Sweden in late spring 2016. This conference originated as a methods meeting focused on in vivo voltammetric techniques and microdialysis. Over time, however, the scope has evolved to include a number of other methods for neurochemical detection that range from single-cell fluorescence in vitro and in vivo in animal models to whole-brain imaging in humans. Overall, MMiN provides a unique forum for introducing new developments in neurochemical detection, as well as for reporting exciting neurobiological insights provided by established and novel methods. This Viewpoint includes a brief history of the meeting, factors that have contributed its evolution, and some highlights of MMiN 2016. PMID:28169519

  6. Monitoring Molecules in Neuroscience Then and Now.

    PubMed

    Rice, Margaret E

    2017-02-15

    The 16th International Conference on Monitoring Molecules in Neuroscience (MMiN) was held in Gothenburg, Sweden in late spring 2016. This conference originated as a methods meeting focused on in vivo voltammetric techniques and microdialysis. Over time, however, the scope has evolved to include a number of other methods for neurochemical detection that range from single-cell fluorescence in vitro and in vivo in animal models to whole-brain imaging in humans. Overall, MMiN provides a unique forum for introducing new developments in neurochemical detection, as well as for reporting exciting neurobiological insights provided by established and novel methods. This Viewpoint includes a brief history of the meeting, factors that have contributed its evolution, and some highlights of MMiN 2016.

  7. Comparison of a New High-Frequency Electric Welding System for Intestinal Closure with Hand-Sewn In Vivo Pig Model.

    PubMed

    Han, Shuai; Cai, Zhai; Ning, Xuanjing; He, Linyun; Chen, Jun; Huang, Zonghai; Zhou, Huabin; Huang, Dequn; Zhang, Pusheng; Li, Zhou

    2015-08-01

    Various surgical small intestinal anastomosis methods are in current use, but improvements are always desired. Thus, we compared the feasibility, effectiveness, and safety of a new high-frequency electric welding (HFEW) system for sealing the small bowel versus a hand-sewn in vivo pig model. The 96 bowel segments of three pigs were randomized to be sutured either by the HFEW-300 PATONMED device (E.O. Paton Electric Welding Institute of the National Academy of Sciences of Ukraine, Kiev, Ukraine) or hand-sewn, and mucosa-to-mucosa fusions were subjected in vivo testing in the pigs. Bursting pressures, suture time, thermal damage, and the temperature of sealed ends were measured. Segments that had been treated with a hand-sutured ligature or double-sealed with HFEW were compared. Burst pressure was significantly higher in the hand-sutured group than in the HFEW group (136.2 mm Hg versus 75.8 mm Hg, P<.01). All 48 pig small bowels closed by the HFEW-300 generator showed a success rate of 100.0%. The closing time in the HFEW group was significantly shorter (P<.01). The pathological changes of the closed ends were mainly presented as acute thermal- and pressure-induced injuries. Outcomes of the current in vivo study suggest that HFEW is an effective and safe method for ligation of the small bowel in pigs.

  8. Analysis of mitosis and antimitotic drug responses in tumors by in vivo microscopy and single-cell pharmacodynamics.

    PubMed

    Orth, James D; Kohler, Rainer H; Foijer, Floris; Sorger, Peter K; Weissleder, Ralph; Mitchison, Timothy J

    2011-07-01

    Cancer relies upon frequent or abnormal cell division, but how the tumor microenvironment affects mitotic processes in vivo remains unclear, largely due to the technical challenges of optical access, spatial resolution, and motion. We developed high-resolution in vivo microscopy methods to visualize mitosis in a murine xenograft model of human cancer. Using these methods, we determined whether the single-cell response to the antimitotic drug paclitaxel (Ptx) was the same in tumors as in cell culture, observed the impact of Ptx on the tumor response as a whole, and evaluated the single-cell pharmacodynamics (PD) of Ptx (by in vivo PD microscopy). Mitotic initiation was generally less frequent in tumors than in cell culture, but subsequently it proceeded normally. Ptx treatment caused spindle assembly defects and mitotic arrest, followed by slippage from mitotic arrest, multinucleation, and apoptosis. Compared with cell culture, the peak mitotic index in tumors exposed to Ptx was lower and the tumor cells survived longer after mitotic arrest, becoming multinucleated rather than dying directly from mitotic arrest. Thus, the tumor microenvironment was much less proapoptotic than cell culture. The morphologies associated with mitotic arrest were dose and time dependent, thereby providing a semiquantitative, single-cell measure of PD. Although many tumor cells did not progress through Ptx-induced mitotic arrest, tumor significantly regressed in the model. Our findings show that in vivo microscopy offers a useful tool to visualize mitosis during tumor progression, drug responses, and cell fate at the single-cell level. ©2011 AACR.

  9. An alternative continence tube for continent urinary reservoirs: evaluation of surgical technique, pressure and continence study in an ex-vivo model.

    PubMed

    Honeck, Patrick; Michel, Maurice Stephan; Trojan, Lutz; Alken, Peter

    2009-02-01

    Despite the large number of surgical techniques for continent cutaneous diversion described in literature, the creation of a reliable, continent and easily catheterizable continence mechanism remains a complex surgical procedure. Aim of this study was the evaluation of a new method for a catheterizable continence mechanism using stapled pig intestine. Small and large pig intestines were used for construction. A 3 or 6 cm double row stapling system was used. Three variations using small and large intestine segments were constructed. A 3 or 6 cm long stapler line was placed alongside a 12 Fr catheter positioned at the antimesenterial side creating a partially two-luminal segment. Construction time for the tube was measured. The created tube was then embedded into the pouch. Pressure evaluation of the continence mechanism was performed for each variation. Intermittent external manual compression was used to simulate sudden pressure exposure. All variations were 100% continent under filling volumes of up to 700 ml and pressure levels of 58 +/- 6 cm H(2)O for large intestine and 266 ml and 87 +/- 18 cm H(2)O for small intestine, respectively. With further filling above the mentioned capacity suture insufficiency occurred but no tube insufficiency. Construction time for all variations was less than 12 min. The described technique is an easy and fast method to construct a continence mechanism using small or large intestine. Our ex vivo experiments have shown sufficient continence situation in an ex-vivo model. Further investigations in an in-vivo model are needed to confirm these results.

  10. Prediction of human pharmacokinetics using physiologically based modeling: a retrospective analysis of 26 clinically tested drugs.

    PubMed

    De Buck, Stefan S; Sinha, Vikash K; Fenu, Luca A; Nijsen, Marjoleen J; Mackie, Claire E; Gilissen, Ron A H J

    2007-10-01

    The aim of this study was to evaluate different physiologically based modeling strategies for the prediction of human pharmacokinetics. Plasma profiles after intravenous and oral dosing were simulated for 26 clinically tested drugs. Two mechanism-based predictions of human tissue-to-plasma partitioning (P(tp)) from physicochemical input (method Vd1) were evaluated for their ability to describe human volume of distribution at steady state (V(ss)). This method was compared with a strategy that combined predicted and experimentally determined in vivo rat P(tp) data (method Vd2). Best V(ss) predictions were obtained using method Vd2, providing that rat P(tp) input was corrected for interspecies differences in plasma protein binding (84% within 2-fold). V(ss) predictions from physicochemical input alone were poor (32% within 2-fold). Total body clearance (CL) was predicted as the sum of scaled rat renal clearance and hepatic clearance projected from in vitro metabolism data. Best CL predictions were obtained by disregarding both blood and microsomal or hepatocyte binding (method CL2, 74% within 2-fold), whereas strong bias was seen using both blood and microsomal or hepatocyte binding (method CL1, 53% within 2-fold). The physiologically based pharmacokinetics (PBPK) model, which combined methods Vd2 and CL2 yielded the most accurate predictions of in vivo terminal half-life (69% within 2-fold). The Gastroplus advanced compartmental absorption and transit model was used to construct an absorption-disposition model and provided accurate predictions of area under the plasma concentration-time profile, oral apparent volume of distribution, and maximum plasma concentration after oral dosing, with 74%, 70%, and 65% within 2-fold, respectively. This evaluation demonstrates that PBPK models can lead to reasonable predictions of human pharmacokinetics.

  11. Clinical Implementation of a Model-Based In Vivo Dose Verification System for Stereotactic Body Radiation Therapy–Volumetric Modulated Arc Therapy Treatments Using the Electronic Portal Imaging Device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCowan, Peter M., E-mail: pmccowan@cancercare.mb.ca; Asuni, Ganiyu; Van Uytven, Eric

    Purpose: To report findings from an in vivo dosimetry program implemented for all stereotactic body radiation therapy patients over a 31-month period and discuss the value and challenges of utilizing in vivo electronic portal imaging device (EPID) dosimetry clinically. Methods and Materials: From December 2013 to July 2016, 117 stereotactic body radiation therapy–volumetric modulated arc therapy patients (100 lung, 15 spine, and 2 liver) underwent 602 EPID-based in vivo dose verification events. A developed model-based dose reconstruction algorithm calculates the 3-dimensional dose distribution to the patient by back-projecting the primary fluence measured by the EPID during treatment. The EPID frame-averaging was optimized in Junemore » 2015. For each treatment, a 3%/3-mm γ comparison between our EPID-derived dose and the Eclipse AcurosXB–predicted dose to the planning target volume (PTV) and the ≥20% isodose volume were performed. Alert levels were defined as γ pass rates <85% (lung and liver) and <80% (spine). Investigations were carried out for all fractions exceeding the alert level and were classified as follows: EPID-related, algorithmic, patient setup, anatomic change, or unknown/unidentified errors. Results: The percentages of fractions exceeding the alert levels were 22.6% for lung before frame-average optimization and 8.0% for lung, 20.0% for spine, and 10.0% for liver after frame-average optimization. Overall, mean (± standard deviation) planning target volume γ pass rates were 90.7% ± 9.2%, 87.0% ± 9.3%, and 91.2% ± 3.4% for the lung, spine, and liver patients, respectively. Conclusions: Results from the clinical implementation of our model-based in vivo dose verification method using on-treatment EPID images is reported. The method is demonstrated to be valuable for routine clinical use for verifying delivered dose as well as for detecting errors.« less

  12. Quantitative evaluation of the disintegration of orally rapid disintegrating tablets by X-ray computed tomography.

    PubMed

    Otsuka, Makoto; Yamanaka, Azusa; Uchino, Tomohiro; Otsuka, Kuniko; Sadamoto, Kiyomi; Ohshima, Hiroyuki

    2012-01-01

    To measure the rapid disintegration of Oral Disintegrating Tablets (ODT), a new test (XCT) was developed using X-ray computing tomography (X-ray CT). Placebo ODT, rapid disintegration candy (RDC) and Gaster®-D-Tablets (GAS) were used as model samples. All these ODTs were used to measure oral disintegration time (DT) in distilled water at 37±2°C by XCT. DTs were affected by the width of mesh screens, and degree to which the tablet holder vibrated from air bubbles. An in-vivo tablet disintegration test was performed for RDC using 11 volunteers. DT by the in-vivo method was significantly longer than that using the conventional tester. The experimental conditions for XCT such as the width of the mesh screen and degree of vibration were adjusted to be consistent with human DT values. Since DTs by the XCT method were almost the same as the human data, this method was able to quantitatively evaluate the rapid disintegration of ODT under the same conditions as inside the oral cavity. The DTs of four commercially available ODTs were comparatively evaluated by the XCT method, conventional tablet disintegration test and in-vivo method.

  13. MUSCLEMOTION: A Versatile Open Software Tool to Quantify Cardiomyocyte and Cardiac Muscle Contraction In Vitro and In Vivo.

    PubMed

    Sala, Luca; van Meer, Berend J; Tertoolen, Leon G J; Bakkers, Jeroen; Bellin, Milena; Davis, Richard P; Denning, Chris; Dieben, Michel A E; Eschenhagen, Thomas; Giacomelli, Elisa; Grandela, Catarina; Hansen, Arne; Holman, Eduard R; Jongbloed, Monique R M; Kamel, Sarah M; Koopman, Charlotte D; Lachaud, Quentin; Mannhardt, Ingra; Mol, Mervyn P H; Mosqueira, Diogo; Orlova, Valeria V; Passier, Robert; Ribeiro, Marcelo C; Saleem, Umber; Smith, Godfrey L; Burton, Francis L; Mummery, Christine L

    2018-02-02

    There are several methods to measure cardiomyocyte and muscle contraction, but these require customized hardware, expensive apparatus, and advanced informatics or can only be used in single experimental models. Consequently, data and techniques have been difficult to reproduce across models and laboratories, analysis is time consuming, and only specialist researchers can quantify data. Here, we describe and validate an automated, open-source software tool (MUSCLEMOTION) adaptable for use with standard laboratory and clinical imaging equipment that enables quantitative analysis of normal cardiac contraction, disease phenotypes, and pharmacological responses. MUSCLEMOTION allowed rapid and easy measurement of movement from high-speed movies in (1) 1-dimensional in vitro models, such as isolated adult and human pluripotent stem cell-derived cardiomyocytes; (2) 2-dimensional in vitro models, such as beating cardiomyocyte monolayers or small clusters of human pluripotent stem cell-derived cardiomyocytes; (3) 3-dimensional multicellular in vitro or in vivo contractile tissues, such as cardiac "organoids," engineered heart tissues, and zebrafish and human hearts. MUSCLEMOTION was effective under different recording conditions (bright-field microscopy with simultaneous patch-clamp recording, phase contrast microscopy, and traction force microscopy). Outcomes were virtually identical to the current gold standards for contraction measurement, such as optical flow, post deflection, edge-detection systems, or manual analyses. Finally, we used the algorithm to quantify contraction in in vitro and in vivo arrhythmia models and to measure pharmacological responses. Using a single open-source method for processing video recordings, we obtained reliable pharmacological data and measures of cardiac disease phenotype in experimental cell, animal, and human models. © 2017 The Authors.

  14. Methods of in-vivo mouse lung micro-CT

    NASA Astrophysics Data System (ADS)

    Recheis, Wolfgang A.; Nixon, Earl; Thiesse, Jacqueline; McLennan, Geoffrey; Ross, Alan; Hoffman, Eric

    2005-04-01

    Micro-CT will have a profound influence on the accumulation of anatomical and physiological phenotypic changes in natural and transgenetic mouse models. Longitudinal studies will be greatly facilitated, allowing for a more complete and accurate description of events if in-vivo studies are accomplished. The purpose of the ongoing project is to establish a feasible and reproducible setup for in-vivo mouse lung micro-computed tomography (μCT). We seek to use in-vivo respiratory-gated μCT to follow mouse models of lung disease with subsequent recovery of the mouse. Methodologies for optimizing scanning parameters and gating for the in-vivo mouse lung are presented. A Scireq flexiVent ventilated the gas-anesthetized mice at 60 breaths/minute, 30 cm H20 PEEP, 30 ml/kg tidal volume and provided a respiratory signal to gate a Skyscan 1076 μCT. Physiologic monitoring allowed the control of vital functions and quality of anesthesia, e.g. via ECG monitoring. In contrary to longer exposure times with ex-vivo scans, scan times for in-vivo were reduced using 35μm pixel size, 158ms exposure time and 18μm pixel size, 316ms exposure time to reduce motion artifacts. Gating via spontaneous breathing was also tested. Optimal contrast resolution was achieved at 50kVp, 200μA, applying an aluminum filter (0.5mm). There were minimal non-cardiac related motion artifacts. Both 35μm and 1μm voxel size images were suitable for evaluation of the airway lumen and parenchymal density. Total scan times were 30 and 65 minutes respectively. The mice recovered following scanning protocols. In-vivo lung scanning with recovery of the mouse delivered reasonable image quality for longitudinal studies, e.g. mouse asthma models. After examining 10 mice, we conclude μCT is a feasible tool evaluating mouse models of lung pathology in longitudinal studies with increasing anatomic detail available for evaluation as one moves from in-vivo to ex-vivo studies. Further developments include automated bronchial tree segmentation and airway wall thickness measurement tools. Improvements in Hounsfield unit calibration have to be performed when the interest of the study lies in determining and quantifying parenchymal changes and rely on estimating partial volume contributions of underlying structures to voxel densities.

  15. Modelling human skull growth: a validated computational model

    PubMed Central

    Marghoub, Arsalan; Johnson, David; Khonsari, Roman H.; Fagan, Michael J.; Moazen, Mehran

    2017-01-01

    During the first year of life, the brain grows rapidly and the neurocranium increases to about 65% of its adult size. Our understanding of the relationship between the biomechanical forces, especially from the growing brain, the craniofacial soft tissue structures and the individual bone plates of the skull vault is still limited. This basic knowledge could help in the future planning of craniofacial surgical operations. The aim of this study was to develop a validated computational model of skull growth, based on the finite-element (FE) method, to help understand the biomechanics of skull growth. To do this, a two-step validation study was carried out. First, an in vitro physical three-dimensional printed model and an in silico FE model were created from the same micro-CT scan of an infant skull and loaded with forces from the growing brain from zero to two months of age. The results from the in vitro model validated the FE model before it was further developed to expand from 0 to 12 months of age. This second FE model was compared directly with in vivo clinical CT scans of infants without craniofacial conditions (n = 56). The various models were compared in terms of predicted skull width, length and circumference, while the overall shape was quantified using three-dimensional distance plots. Statistical analysis yielded no significant differences between the male skull models. All size measurements from the FE model versus the in vitro physical model were within 5%, with one exception showing a 7.6% difference. The FE model and in vivo data also correlated well, with the largest percentage difference in size being 8.3%. Overall, the FE model results matched well with both the in vitro and in vivo data. With further development and model refinement, this modelling method could be used to assist in preoperative planning of craniofacial surgery procedures and could help to reduce reoperation rates. PMID:28566514

  16. Modelling human skull growth: a validated computational model.

    PubMed

    Libby, Joseph; Marghoub, Arsalan; Johnson, David; Khonsari, Roman H; Fagan, Michael J; Moazen, Mehran

    2017-05-01

    During the first year of life, the brain grows rapidly and the neurocranium increases to about 65% of its adult size. Our understanding of the relationship between the biomechanical forces, especially from the growing brain, the craniofacial soft tissue structures and the individual bone plates of the skull vault is still limited. This basic knowledge could help in the future planning of craniofacial surgical operations. The aim of this study was to develop a validated computational model of skull growth, based on the finite-element (FE) method, to help understand the biomechanics of skull growth. To do this, a two-step validation study was carried out. First, an in vitro physical three-dimensional printed model and an in silico FE model were created from the same micro-CT scan of an infant skull and loaded with forces from the growing brain from zero to two months of age. The results from the in vitro model validated the FE model before it was further developed to expand from 0 to 12 months of age. This second FE model was compared directly with in vivo clinical CT scans of infants without craniofacial conditions ( n = 56). The various models were compared in terms of predicted skull width, length and circumference, while the overall shape was quantified using three-dimensional distance plots. Statistical analysis yielded no significant differences between the male skull models. All size measurements from the FE model versus the in vitro physical model were within 5%, with one exception showing a 7.6% difference. The FE model and in vivo data also correlated well, with the largest percentage difference in size being 8.3%. Overall, the FE model results matched well with both the in vitro and in vivo data. With further development and model refinement, this modelling method could be used to assist in preoperative planning of craniofacial surgery procedures and could help to reduce reoperation rates. © 2017 The Author(s).

  17. Imaging modalities for the in vivo surveillance of mesenchymal stromal cells.

    PubMed

    Hossain, Mohammad Ayaz; Chowdhury, Tina; Bagul, Atul

    2015-11-01

    Bone marrow stromal cells exist as mesenchymal stromal cells (MSCs) and have the capacity to differentiate into multiple tissue types when subjected to appropriate culture conditions. This property of MSCs creates therapeutic opportunities in regenerative medicine for the treatment of damage to neural, cardiac and musculoskeletal tissues or acute kidney injury. The prerequisite for successful cell therapy is delivery of cells to the target tissue. Assessment of therapeutic outcomes utilize traditional methods to examine cell function of MSC populations involving routine biochemical or histological analysis for cell proliferation, protein synthesis and gene expression. However, these methods do not provide sufficient spatial and temporal information. In vivo surveillance of MSC migration to the site of interest can be performed through a variety of imaging modalities such as the use of radiolabelling, fluc protein expression bioluminescence imaging and paramagnetic nanoparticle magnetic resonance imaging. This review will outline the current methods of in vivo surveillance of exogenously administered MSCs in regenerative medicine while addressing potential technological developments. Furthermore, nanoparticles and microparticles for cellular labelling have shown that migration of MSCs can be spatially and temporally monitored. In vivo surveillance therefore permits time-stratified assessment in animal models without disruption of the target organ. In vivo tracking of MSCs is non-invasive, repeatable and non-toxic. Despite the excitement that nanoparticles for tracking MSCs offer, delivery methods are difficult because of the challenges with imaging three-dimensional systems. The current advances and growth in MSC research, is likely to provide a wealth of evidence overcoming these issues. Copyright © 2014 John Wiley & Sons, Ltd.

  18. Animal models in peritoneal dialysis.

    PubMed

    Nikitidou, Olga; Peppa, Vasiliki I; Leivaditis, Konstantinos; Eleftheriadis, Theodoros; Zarogiannis, Sotirios G; Liakopoulos, Vassilios

    2015-01-01

    Peritoneal dialysis (PD) has been extensively used over the past years as a method of kidney replacement therapy for patients with end stage renal disease (ESRD). In an attempt to better understand the properties of the peritoneal membrane and the mechanisms involved in major complications associated with PD, such as inflammation, peritonitis and peritoneal injury, both in vivo and ex vivo animal models have been used. The aim of the present review is to briefly describe the animal models that have been used, and comment on the main problems encountered while working with these models. Moreover, the differences characterizing these animal models, as well as, the differences with humans are highlighted. Finally, it is suggested that the use of standardized protocols is a necessity in order to take full advantage of animal models, extrapolate their results in humans, overcome the problems related to PD and help promote its use.

  19. In vivo three-dimensional photoacoustic imaging of the renal vasculature in preclinical rodent models.

    PubMed

    Ogunlade, Olumide; Connell, John J; Huang, Jennifer L; Zhang, Edward; Lythgoe, Mark F; Long, David A; Beard, Paul

    2018-06-01

    Noninvasive imaging of the kidney vasculature in preclinical murine models is important for the assessment of renal development, studying diseases and evaluating new therapies but is challenging to achieve using existing imaging modalities. Photoacoustic imaging is a promising new technique that is particularly well suited to visualizing the vasculature and could provide an alternative to existing preclinical imaging methods for studying renal vascular anatomy and function. To investigate this, an all-optical Fabry-Perot-based photoacoustic scanner was used to image the abdominal region of mice. High-resolution three-dimensional, noninvasive, label-free photoacoustic images of the mouse kidney and renal vasculature were acquired in vivo. The scanner was also used to visualize and quantify differences in the vascular architecture of the kidney in vivo due to polycystic kidney disease. This study suggests that photoacoustic imaging could be utilized as a novel preclinical imaging tool for studying the biology of renal disease.

  20. Designing in vivo concentration gradients with discrete controlled release: a computational model

    NASA Astrophysics Data System (ADS)

    Walker, Edgar Y.; Barbour, Dennis L.

    2010-08-01

    One promising neurorehabilitation therapy involves presenting neurotrophins directly into the brain to induce growth of new neural connections. The precise control of neurotrophin concentration gradients deep within neural tissue that would be necessary for such a therapy is not currently possible, however. Here we evaluate the theoretical potential of a novel method of drug delivery, discrete controlled release (DCR), to control effective neurotrophin concentration gradients in an isotropic region of neocortex. We do so by constructing computational models of neurotrophin concentration profiles resulting from discrete release locations into the cortex and then optimizing their design for uniform concentration gradients. The resulting model indicates that by rationally selecting initial neurotrophin concentrations for drug-releasing electrode coatings in a square 16-electrode array, nearly uniform concentration gradients (i.e. planar concentration profiles) from one edge of the electrode array to the other should be obtainable. DCR therefore represents a promising new method of precisely directing neuronal growth in vivo over a wider spatial profile than would be possible with single release points.

  1. Evaluating the interaction of a tracheobronchial stent in an ovine in-vivo model.

    PubMed

    McGrath, Donnacha J; Thiebes, Anja Lena; Cornelissen, Christian G; O'Brien, Barry; Jockenhoevel, Stefan; Bruzzi, Mark; McHugh, Peter E

    2018-04-01

    Tracheobronchial stents are used to restore patency to stenosed airways. However, these devices are associated with many complications such as stent migration, granulation tissue formation, mucous plugging and stent strut fracture. Of these, granulation tissue formation is the complication that most frequently requires costly secondary interventions. In this study a biomechanical lung modelling framework recently developed by the authors to capture the lung in-vivo stress state under physiological loading is employed in conjunction with ovine pre-clinical stenting results and device experimental data to evaluate the effect of stent interaction on granulation tissue formation. Stenting is simulated using a validated model of a prototype covered laser-cut tracheobronchial stent in a semi-specific biomechanical lung model, and physiological loading is performed. Two computational methods are then used to predict possible granulation tissue formation: the standard method which utilises the increase in maximum principal stress change, and a newly proposed method which compares the change in contact pressure over a respiratory cycle. These computational predictions of granulation tissue formation are then compared to pre-clinical stenting observations after a 6-week implantation period. Experimental results of the pre-clinical stent implantation showed signs of granulation tissue formation both proximally and distally, with a greater proximal reaction. The standard method failed to show a correlation with the experimental results. However, the contact change method showed an apparent correlation with granulation tissue formation. These results suggest that this new method could be used as a tool to improve future device designs.

  2. Sensitivity of Chemical Shift-Encoded Fat Quantification to Calibration of Fat MR Spectrum

    PubMed Central

    Wang, Xiaoke; Hernando, Diego; Reeder, Scott B.

    2015-01-01

    Purpose To evaluate the impact of different fat spectral models on proton density fat-fraction (PDFF) quantification using chemical shift-encoded (CSE) MRI. Material and Methods Simulations and in vivo imaging were performed. In a simulation study, spectral models of fat were compared pairwise. Comparison of magnitude fitting and mixed fitting was performed over a range of echo times and fat fractions. In vivo acquisitions from 41 patients were reconstructed using 7 published spectral models of fat. T2-corrected STEAM-MRS was used as reference. Results Simulations demonstrate that imperfectly calibrated spectral models of fat result in biases that depend on echo times and fat fraction. Mixed fitting is more robust against this bias than magnitude fitting. Multi-peak spectral models showed much smaller differences among themselves than when compared to the single-peak spectral model. In vivo studies show all multi-peak models agree better (for mixed fitting, slope ranged from 0.967–1.045 using linear regression) with reference standard than the single-peak model (for mixed fitting, slope=0.76). Conclusion It is essential to use a multi-peak fat model for accurate quantification of fat with CSE-MRI. Further, fat quantification techniques using multi-peak fat models are comparable and no specific choice of spectral model is shown to be superior to the rest. PMID:25845713

  3. In Vivo Investigation of Breast Cancer Progression by Use of an Internal Control1

    PubMed Central

    Baeten, John; Haller, Jodi; Shih, Helen; Ntziachristos, Vasilis

    2009-01-01

    Optical imaging of breast cancer has been considered for detecting functional and molecular characteristics of diseases in clinical and preclinical settings. Applied to laboratory research, photonic investigations offer a highly versatile tool for preclinical imaging and drug discovery. A particular advantage of the optical method is the availability of multiple spectral bands for performing imaging. Herein, we capitalize on this feature to demonstrate how it is possible to use different wavelengths to offer internal controls and significantly improve the observation accuracy in molecular imaging applications. In particular, we show the independent in vivo detection of cysteine proteases along with tumor permeability and interstitial volume measurements using a dual-wavelength approach. To generate results with a view toward clinically geared studies, a transgenic Her2/neu mouse model that spontaneously developed mammary tumors was used. In vivo findings were validated against conventional ex vivo tests such as histology and Western blot analyses. By correcting for biodistribution parameters, the dual-wavelength method increases the accuracy of molecular observations by separating true molecular target from probe biodistribution. As such, the method is highly appropriate for molecular imaging studies where often probe delivery and target presence are not independently assessed. On the basis of these findings, we propose the dual-wavelength/normalization approach as an essential method for drug discovery and preclinical imaging studies. PMID:19242603

  4. A novel in vivo model of puncture-induced iris neovascularization.

    PubMed

    Beaujean, Ophélie; Locri, Filippo; Aronsson, Monica; Kvanta, Anders; André, Helder

    2017-01-01

    To assess iris neovascularization by uveal puncture of the mouse eye and determine the role of angiogenic factors during iris neovascularization. Uveal punctures were performed on BalbC mouse eyes to induce iris angiogenesis. VEGF-blockage was used as an anti-angiogenic treatment, while normoxia- and hypoxia-conditioned media from retinal pigment epithelium (RPE) cells was used as an angiogenic-inducer in this model. Iris vasculature was determined in vivo by noninvasive methods. Iris blood vessels were stained for platelet endothelial cell adhesion molecule-1 and vascular sprouts were counted as markers of angiogenesis. Expression of angiogenic and inflammatory factors in the puncture-induced model were determined by qPCR and western blot. Punctures led to increased neovascularization and sprouting of the iris. qPCR and protein analysis showed an increase of angiogenic factors, particularly in the plasminogen-activating receptor and inflammatory systems. VEGF-blockage partly reduced iris neovascularization, and treatment with hypoxia-conditioned RPE medium led to a statistically significant increase in iris neovascularization. This study presents the first evidence of a puncture-induced iris angiogenesis model in the mouse. In a broader context, this novel in vivo model of neovascularization has the potential for noninvasive evaluation of angiogenesis modulating substances.

  5. Imaging Agonist-Induced D2/D3 Receptor Desensitization and Internalization In Vivo with PET/fMRI.

    PubMed

    Sander, Christin Y; Hooker, Jacob M; Catana, Ciprian; Rosen, Bruce R; Mandeville, Joseph B

    2016-04-01

    This study investigated the dynamics of dopamine receptor desensitization and internalization, thereby proposing a new technique for non-invasive, in vivo measurements of receptor adaptations. The D2/D3 agonist quinpirole, which induces receptor internalization in vitro, was administered at graded doses in non-human primates while imaging with simultaneous positron emission tomography (PET) and functional magnetic resonance imaging (fMRI). A pronounced temporal divergence between receptor occupancy and fMRI signal was observed: occupancy remained elevated while fMRI responded transiently. Analogous experiments with an antagonist (prochlorperazine) and a lower-affinity agonist (ropinirole) exhibited reduced temporal dissociation between occupancy and function, consistent with a mechanism of desensitization and internalization that depends upon drug efficacy and affinity. We postulated a model that incorporates internalization into a neurovascular-coupling relationship. This model yielded in vivo desensitization/internalization rates (0.2/min for quinpirole) consistent with published in vitro measurements. Overall, these results suggest that simultaneous PET/fMRI enables characterization of dynamic neuroreceptor adaptations in vivo, and may offer a first non-invasive method for assessing receptor desensitization and internalization.

  6. Imaging Agonist-Induced D2/D3 Receptor Desensitization and Internalization In Vivo with PET/fMRI

    PubMed Central

    Sander, Christin Y; Hooker, Jacob M; Catana, Ciprian; Rosen, Bruce R; Mandeville, Joseph B

    2016-01-01

    This study investigated the dynamics of dopamine receptor desensitization and internalization, thereby proposing a new technique for non-invasive, in vivo measurements of receptor adaptations. The D2/D3 agonist quinpirole, which induces receptor internalization in vitro, was administered at graded doses in non-human primates while imaging with simultaneous positron emission tomography (PET) and functional magnetic resonance imaging (fMRI). A pronounced temporal divergence between receptor occupancy and fMRI signal was observed: occupancy remained elevated while fMRI responded transiently. Analogous experiments with an antagonist (prochlorperazine) and a lower-affinity agonist (ropinirole) exhibited reduced temporal dissociation between occupancy and function, consistent with a mechanism of desensitization and internalization that depends upon drug efficacy and affinity. We postulated a model that incorporates internalization into a neurovascular-coupling relationship. This model yielded in vivo desensitization/internalization rates (0.2/min for quinpirole) consistent with published in vitro measurements. Overall, these results suggest that simultaneous PET/fMRI enables characterization of dynamic neuroreceptor adaptations in vivo, and may offer a first non-invasive method for assessing receptor desensitization and internalization. PMID:26388148

  7. Noninvasive Determination of Bone Mechanical Properties using Vibration Response: A Refined Model and Validation in vivo

    NASA Technical Reports Server (NTRS)

    Roberts, S. G.; Hutchinson, T. M.; Arnaud, S. B.; Steele, C. R.; Kiratli, B. J.; Martin, R. B.

    1996-01-01

    Accurate non-invasive mechanical measurement of long bones is made difficult by the masking effect of surrounding soft tissues. Mechanical Response Tissue Analysis (MRTA) offers a method for separating the effects of the soft tissue and bone; however, a direct validation has been lacking. A theoretical analysis of wave propagation through the compressed tissue revealed a strong mass effect dependent on the relative accelerations of the probe and bone. The previous mathematical model of the bone and overlying tissue system was reconfigured to incorporate the theoretical finding. This newer model (six-parameter) was used to interpret results using MRTA to determine bone cross-sectional bending stiffness, EI(sub MRTA). The relationship between EI(MRTA) and theoretical EI values for padded aluminum rods was R(exp 2) = 0.999. A biological validation followed using monkey tibias. Each bone was tested in vivo with the MRTA instrument. Postmortem, the same tibias were excised and tested to failure in three-point bending to determine EI(sub 3-PT) and maximum load. Diaphyseal Bone Mineral Density (BMD) measurements were also made. The relationship between E(sub 3-PT) and in vivo EI(sub MRTA) using the six-parameter model is strong (R(exp 2) = 0.947) and better than that using the older model (R(exp 2) = 0.645). EI(MRTA) and BMD are also highly correlated (R(exp 2) = 0.853). MRTA measurements in vivo and BMD ex vivo are both good predictors of scaled maximum strength (R(exp 2) = 0.915 and R(exp 2) = 0.894, respectively). This is the first biological validation of a non-invasive mechanical measurement of bone by comparison to actual values. The MRTA technique has potential clinical value for assessing long-bone mechanical properties.

  8. Noninvasive Determination of Bone Mechanical Properties Using Vibration Response: A Refined Model and Validation in vivo

    NASA Technical Reports Server (NTRS)

    Roberts, S. G.; Hutchinson, T. M.; Arnaud, S. B.; Kiratli, B. J; Steele, C. R.

    1996-01-01

    Accurate non-invasive mechanical measurement of long bones is made difficult by the masking effect of surrounding soft tissues. Mechanical response tissue analysis (MRTA) offers a method for separating the effects of the soft tissue and bone; however, a direct validation has been lacking. A theoretical analysis of wave propagation through the compressed tissue revealed a strong mass effect dependent on the relative accelerations of the probe and bone. The previous mathematical model of the bone and overlying tissue system was reconfigured to incorporate the theoretical finding. This newer model (six-parameter) was used to interpret results using MRTA to determine bone cross-sectional bending stiffness, EI(sub MRTA). The relationship between EI(sub MRTA) and theoretical EI values for padded aluminum rods was R(sup 2) = 0.999. A biological validation followed using monkey tibias. Each bone was tested in vivo with the MRTA instrument. Postmortem, the same tibias were excised and tested to failure in three-point bending to determine EI(sub 3-PT) and maximum load. Diaphyseal bone mineral density (BMD) measurements were also made. The relationship between EI(sub 3-PT) and in vivo EI(sub MRTA) using the six-parameter model is strong (R(sup 2) = 0.947) and better than that using the older model (R(sup 2) = 0.645). EI(sub MRTA) and BMD are also highly correlated (R(sup 2) = 0.853). MRTA measurements in vivo and BMD ex vivo are both good predictors of scaled maximum strength (R(sup 2) = 0.915 and R(sup 2) = 0.894, respectively). This is the first biological validation of a non- invasive mechanical measurement of bone by comparison to actual values. The MRTA technique has potential clinical value for assessing long-bone mechanical properties.

  9. Prediction of In Vivo Knee Joint Kinematics Using a Combined Dual Fluoroscopy Imaging and Statistical Shape Modeling Technique

    PubMed Central

    Li, Jing-Sheng; Tsai, Tsung-Yuan; Wang, Shaobai; Li, Pingyue; Kwon, Young-Min; Freiberg, Andrew; Rubash, Harry E.; Li, Guoan

    2014-01-01

    Using computed tomography (CT) or magnetic resonance (MR) images to construct 3D knee models has been widely used in biomedical engineering research. Statistical shape modeling (SSM) method is an alternative way to provide a fast, cost-efficient, and subject-specific knee modeling technique. This study was aimed to evaluate the feasibility of using a combined dual-fluoroscopic imaging system (DFIS) and SSM method to investigate in vivo knee kinematics. Three subjects were studied during a treadmill walking. The data were compared with the kinematics obtained using a CT-based modeling technique. Geometric root-mean-square (RMS) errors between the knee models constructed using the SSM and CT-based modeling techniques were 1.16 mm and 1.40 mm for the femur and tibia, respectively. For the kinematics of the knee during the treadmill gait, the SSM model can predict the knee kinematics with RMS errors within 3.3 deg for rotation and within 2.4 mm for translation throughout the stance phase of the gait cycle compared with those obtained using the CT-based knee models. The data indicated that the combined DFIS and SSM technique could be used for quick evaluation of knee joint kinematics. PMID:25320846

  10. Species-specific predictive models of developmental toxicity using the ToxCast chemical library

    EPA Science Inventory

    EPA’s ToxCastTM project is profiling the in vitro bioactivity of chemicals to generate predictive models that correlate with observed in vivo toxicity. In vitro profiling methods are based on ToxCast data, consisting of over 600 high-throughput screening (HTS) and high-content sc...

  11. 3D Compressed Sensing for Highly Accelerated Hyperpolarized 13C MRSI With In Vivo Applications to Transgenic Mouse Models of Cancer

    PubMed Central

    Hu, Simon; Lustig, Michael; Balakrishnan, Asha; Larson, Peder E. Z.; Bok, Robert; Kurhanewicz, John; Nelson, Sarah J.; Goga, Andrei; Pauly, John M.; Vigneron, Daniel B.

    2010-01-01

    High polarization of nuclear spins in liquid state through hyperpolarized technology utilizing dynamic nuclear polarization has enabled the direct monitoring of 13C metabolites in vivo at a high signal-to-noise ratio. Acquisition time limitations due to T1 decay of the hyperpolarized signal require accelerated imaging methods, such as compressed sensing, for optimal speed and spatial coverage. In this paper, the design and testing of a new echo-planar 13C three-dimensional magnetic resonance spectroscopic imaging (MRSI) compressed sensing sequence is presented. The sequence provides up to a factor of 7.53 in acceleration with minimal reconstruction artifacts. The key to the design is employing x and y gradient blips during a fly-back readout to pseudorandomly undersample kf-kx-ky space. The design was validated in simulations and phantom experiments where the limits of undersampling and the effects of noise on the compressed sensing nonlinear reconstruction were tested. Finally, this new pulse sequence was applied in vivo in preclinical studies involving transgenic prostate cancer and transgenic liver cancer murine models to obtain much higher spatial and temporal resolution than possible with conventional echo-planar spectroscopic imaging methods. PMID:20017160

  12. Direct numerical simulation of cellular-scale blood flow in microvascular networks

    NASA Astrophysics Data System (ADS)

    Balogh, Peter; Bagchi, Prosenjit

    2017-11-01

    A direct numerical simulation method is developed to study cellular-scale blood flow in physiologically realistic microvascular networks that are constructed in silico following published in vivo images and data, and are comprised of bifurcating, merging, and winding vessels. The model resolves large deformation of individual red blood cells (RBC) flowing in such complex networks. The vascular walls and deformable interfaces of the RBCs are modeled using the immersed-boundary methods. Time-averaged hemodynamic quantities obtained from the simulations agree quite well with published in vivo data. Our simulations reveal that in several vessels the flow rates and pressure drops could be negatively correlated. The flow resistance and hematocrit are also found to be negatively correlated in some vessels. These observations suggest a deviation from the classical Poiseuille's law in such vessels. The cells are observed to frequently jam at vascular bifurcations resulting in reductions in hematocrit and flow rate in the daughter and mother vessels. We find that RBC jamming results in several orders of magnitude increase in hemodynamic resistance, and thus provides an additional mechanism of increased in vivo blood viscosity as compared to that determined in vitro. Funded by NSF CBET 1604308.

  13. In vivo Post-Cardiac Arrest Myocardial Dysfunction is Supported by CaMKII-Mediated Calcium Long-Term Potentiation and Mitigated by Alda-1, an Agonist of Aldehyde Dehydrogenase Type 2

    PubMed Central

    Downey, Peter; Zalewski, Adrian; Rubio, Gabriel R.; Liu, Jing; Homburger, Julian R.; Grunwald, Zachary; Qi, Wei; Bollensdorff, Christian; Thanaporn, Porama; Ali, Ayyaz; Riemer, Kirk; Kohl, Peter; Mochly-Rosen, Daria; Gerstenfeld, Edward; Large, Stephen; Ali, Ziad; Ashley, Euan

    2016-01-01

    Background Survival after sudden cardiac arrest is limited by post-arrest myocardial dysfunction but understanding of this phenomenon is constrained by lack of data from a physiological model of disease. In this study, we established an in vivo model of cardiac arrest and resuscitation, characterized the biology of the associated myocardial dysfunction, and tested novel therapeutic strategies. Methods We developed rodent models of in vivo post-arrest myocardial dysfunction using extra-corporeal membrane oxygenation (ECMO) resuscitation followed by invasive hemodynamics measurement. In post-arrest isolated cardiomyocytes, we assessed mechanical load and Ca2+ induced Ca2+ release (CICR) simultaneously using the micro-carbon-fiber technique and observed reduced function and myofilament calcium sensitivity. We used a novel-designed fiber optic catheter imaging system, and a genetically encoded calcium sensor GCaMP6f, to image CICR in vivo. Results We found potentiation of CICR in isolated cells from this ECMO model and also in cells isolated from an ischemia-reperfusion Langendorff model perfused with oxygenated blood from an arrested animal, but not when reperfused in saline. We established that CICR potentiation begins in vivo. The augmented CICR observed post-arrest was mediated by the activation of Ca2+/calmodulin kinase II (CaMKII). Increased phosphorylation of CaMKII, phospholamban and ryanodine receptor 2 (RyR2) was detected in the post-arrest period. Exogenous adrenergic activation in vivo recapitulated Ca2+ potentiation but was associated with lesser CaMKII activation. Since oxidative stress and aldehydic adduct formation were high post arrest, we tested a small molecule activator of aldehyde dehydrogenase type 2, Alda-1, which reduced oxidative stress, restored calcium and CaMKII homeostasis, and improved cardiac function and post-arrest outcome in vivo. Conclusions Cardiac arrest and reperfusion lead to CaMKII activation and calcium long-term potentiation which support cardiomyocyte contractility in the face of impaired post-ischemic myofilament calcium sensitivity. Alda-1 mitigates these effects, normalizes calcium cycling and improves outcome. PMID:27582424

  14. Optimization of 31P magnetic resonance spectroscopy in vivo

    NASA Astrophysics Data System (ADS)

    Manzhurtsev, A. V.; Akhadov, T. A.; Semenova, N. A.

    2018-01-01

    The main problem of magnetic resonance spectroscopy on phosphorus nuclei (31P MRS) is low signal-to-noise ratio (SNR) of spectra acquired on clinical (3T) scanners. This makes quantitative processing of spectra difficult. The optimization of method on a single-voxel model reported in current work implicates an impact of the spin-lattice (T1) relaxation on SNR, and also evaluates the effectiveness of Image Selected InVivo Spectroscopy (ISIS) pulse sequence modification for the increase of SNR.

  15. Use of in Vitro HTS-Derived Concentration–Response Data as Biological Descriptors Improves the Accuracy of QSAR Models of in Vivo Toxicity

    PubMed Central

    Sedykh, Alexander; Zhu, Hao; Tang, Hao; Zhang, Liying; Richard, Ann; Rusyn, Ivan; Tropsha, Alexander

    2011-01-01

    Background Quantitative high-throughput screening (qHTS) assays are increasingly being used to inform chemical hazard identification. Hundreds of chemicals have been tested in dozens of cell lines across extensive concentration ranges by the National Toxicology Program in collaboration with the National Institutes of Health Chemical Genomics Center. Objectives Our goal was to test a hypothesis that dose–response data points of the qHTS assays can serve as biological descriptors of assayed chemicals and, when combined with conventional chemical descriptors, improve the accuracy of quantitative structure–activity relationship (QSAR) models applied to prediction of in vivo toxicity end points. Methods We obtained cell viability qHTS concentration–response data for 1,408 substances assayed in 13 cell lines from PubChem; for a subset of these compounds, rodent acute toxicity half-maximal lethal dose (LD50) data were also available. We used the k nearest neighbor classification and random forest QSAR methods to model LD50 data using chemical descriptors either alone (conventional models) or combined with biological descriptors derived from the concentration–response qHTS data (hybrid models). Critical to our approach was the use of a novel noise-filtering algorithm to treat qHTS data. Results Both the external classification accuracy and coverage (i.e., fraction of compounds in the external set that fall within the applicability domain) of the hybrid QSAR models were superior to conventional models. Conclusions Concentration–response qHTS data may serve as informative biological descriptors of molecules that, when combined with conventional chemical descriptors, may considerably improve the accuracy and utility of computational approaches for predicting in vivo animal toxicity end points. PMID:20980217

  16. Can conclusions drawn from phantom-based image noise assessments be generalized to in vivo studies for the nonlinear model-based iterative reconstruction method?

    PubMed

    Gomez-Cardona, Daniel; Li, Ke; Hsieh, Jiang; Lubner, Meghan G; Pickhardt, Perry J; Chen, Guang-Hong

    2016-02-01

    Phantom-based objective image quality assessment methods are widely used in the medical physics community. For a filtered backprojection (FBP) reconstruction-based linear or quasilinear imaging system, the use of this methodology is well justified. Many key image quality metrics acquired with phantom studies can be directly applied to in vivo human subject studies. Recently, a variety of image quality metrics have been investigated for model-based iterative image reconstruction (MBIR) methods and several novel characteristics have been discovered in phantom studies. However, the following question remains unanswered: can certain results obtained from phantom studies be generalized to in vivo animal studies and human subject studies? The purpose of this paper is to address this question. One of the most striking results obtained from phantom studies is a novel power-law relationship between noise variance of MBIR (σ(2)) and tube current-rotation time product (mAs): σ(2) ∝ (mAs)(-0.4) [K. Li et al., "Statistical model based iterative reconstruction (MBIR) in clinical CT systems: Experimental assessment of noise performance," Med. Phys. 41, 041906 (15pp.) (2014)]. To examine whether the same power-law works for in vivo cases, experimental data from two types of in vivo studies were analyzed in this paper. All scans were performed with a 64-slice diagnostic CT scanner (Discovery CT750 HD, GE Healthcare) and reconstructed with both FBP and a MBIR method (Veo, GE Healthcare). An Institutional Animal Care and Use Committee-approved in vivo animal study was performed with an adult swine at six mAs levels (10-290). Additionally, human subject data (a total of 110 subjects) acquired from an IRB-approved clinical trial were analyzed. In this clinical trial, a reduced-mAs scan was performed immediately following the standard mAs scan; the specific mAs used for the two scans varied across human subjects and were determined based on patient size and clinical indications. The measurements of σ(2) were performed at different mAs by drawing regions-of-interest (ROIs) in the liver and the subcutaneous fat. By applying a linear least-squares regression, the β values in the power-law relationship σ(2) ∝ (mAs)(-β) were measured for the in vivo data and compared with the value found in phantom experiments. For the in vivo swine study, an exponent of β = 0.43 was found for MBIR, and the coefficient of determination (R(2)) for the corresponding least-squares power-law regression was 0.971. As a reference, the β and R(2) values for FBP were found to be 0.98 and 0.997, respectively, from the same study, which are consistent with the well-known σ(2) ∝ (mAs)(-1.0) relationship for linear CT systems. For the human subject study, the measured β values for the MBIR images were 0.41 ± 0.12 in the liver and 0.37 ± 0.12 in subcutaneous fat. In comparison, the β values for the FBP images were 1.04 ± 0.10 in the liver and 0.97 ± 0.12 in subcutaneous fat. The β values of MBIR and FBP obtained from the in vivo studies were found to be statistically equivalent to the corresponding β values from the phantom study within an equivalency interval of [ - 0.1, 0.1] (p < 0.05); across MBIR and FBP, the difference in β was statistically significant (p < 0.05). Despite the nonlinear nature of the MBIR method, the power-law relationship, σ(2) ∝ (mAs)(-0.4), found from phantom studies can be applied to in vivo animal and human subject studies.

  17. A method to rapidly and accurately compare relative efficacies of non-invasive imaging reporter genes in a mouse model, and its application to luciferase reporters

    PubMed Central

    Gil, Jose S.; Machado, Hidevaldo B.; Herschman, Harvey R.

    2013-01-01

    Purpose Our goal is to develop a simple, quantitative, robust method to compare the efficacy of imaging reporter genes in culture and in vivo. We describe an adenoviral vector-liver transduction procedure, and compare the luciferase reporter efficacies. Procedures Alternative reporter genes are expressed in a common adenoviral vector. Vector amounts used in vivo are based on cell culture titrations, ensuring the same transduction efficacy is used for each vector. After imaging, in vivo and in vitro values are normalized to hepatic vector transduction using quantitative real-time PCR. Results We assayed standard firefly luciferase (FLuc), enhanced firefly luciferase (EFLuc), luciferase 2 (Luc2), humanized Renilla luciferase (hRLuc), Renilla luciferase 8.6-535 (RLuc8.6), and a membrane-bound Gaussia luciferase variant (extGLuc) in cell culture and in vivo. We observed a greater that 100-fold increase in bioluminescent signal for both EFLuc and Luc2 when compared to FLuc, and a greater than 106-fold increase for RLuc8.6 when compared to hRLuc. ExtGLuc was not detectable in liver. Conclusions Our findings contrast, in some cases, with conclusions drawn in prior comparisons of these reporter genes, and demonstrate the need for a standardized method to evaluate alternative reporter genes in vivo. Our procedure can be adapted for reporter genes that utilize alternative imaging modalities (fluorescence, bioluminescence, MRI, SPECT, PET). PMID:21850545

  18. Predictive Modeling of Developmental Toxicity

    EPA Science Inventory

    The use of alternative methods in conjunction with traditional in vivo developmental toxicity testing has the potential to (1) reduce cost and increase throughput of testing the chemical universe, (2) prioritize chemicals for further targeted toxicity testing and risk assessment,...

  19. Toxicokinetic Triage for Environmental Chemicals

    EPA Science Inventory

    Toxicokinetic (TK) models are essential for linking administered doses to blood and tissue concentrations. In vitro-to-in vivo extrapolation (IVIVE) methods have been developed to determine TK from limited in vitro measurements and chemical structure-based property predictions, p...

  20. Bone marrow-on-a-chip replicates hematopoietic niche physiology in vitro.

    PubMed

    Torisawa, Yu-suke; Spina, Catherine S; Mammoto, Tadanori; Mammoto, Akiko; Weaver, James C; Tat, Tracy; Collins, James J; Ingber, Donald E

    2014-06-01

    Current in vitro hematopoiesis models fail to demonstrate the cellular diversity and complex functions of living bone marrow; hence, most translational studies relevant to the hematologic system are conducted in live animals. Here we describe a method for fabricating 'bone marrow-on-a-chip' that permits culture of living marrow with a functional hematopoietic niche in vitro by first engineering new bone in vivo, removing it whole and perfusing it with culture medium in a microfluidic device. The engineered bone marrow (eBM) retains hematopoietic stem and progenitor cells in normal in vivo-like proportions for at least 1 week in culture. eBM models organ-level marrow toxicity responses and protective effects of radiation countermeasure drugs, whereas conventional bone marrow culture methods do not. This biomimetic microdevice offers a new approach for analysis of drug responses and toxicities in bone marrow as well as for study of hematopoiesis and hematologic diseases in vitro.

  1. Development of a terminally sterilised decellularised dermis.

    PubMed

    Hogg, P; Rooney, P; Leow-Dyke, S; Brown, C; Ingham, E; Kearney, J N

    2015-09-01

    Many of the decellularised dermis products on the market at present are aspectically produced. NHS Blood and Transplant Tissue Services have developed a method of producing a dCELL human dermis which has been terminally sterilised by gamma irradiation. The terminally sterilised decellularised dermis was compared with cellular tissue and examined for histology, residual DNA content, biomechanical and biochemical properties, in vitro cytotoxicity and in vivo implantation in a mouse model. No alterations in morphology as viewed by light microscopy were observed and DNA removal was 99%. There were no significant changes in ultimate tensile stress or evidence for collagen denaturation or cytotoxicity. The in vivo studies did not indicate any adverse tissue reactions in the mouse model and demonstrated incorporation of dCELL human dermis into the host. Decellularisation, followed by terminal sterilisation with gamma irradiation, is an appropriate method to produce a human dermis allograft material suitable for transplantation.

  2. Estimating physiological skin parameters from hyperspectral signatures

    NASA Astrophysics Data System (ADS)

    Vyas, Saurabh; Banerjee, Amit; Burlina, Philippe

    2013-05-01

    We describe an approach for estimating human skin parameters, such as melanosome concentration, collagen concentration, oxygen saturation, and blood volume, using hyperspectral radiometric measurements (signatures) obtained from in vivo skin. We use a computational model based on Kubelka-Munk theory and the Fresnel equations. This model forward maps the skin parameters to a corresponding multiband reflectance spectra. Machine-learning-based regression is used to generate the inverse map, and hence estimate skin parameters from hyperspectral signatures. We test our methods using synthetic and in vivo skin signatures obtained in the visible through the short wave infrared domains from 24 patients of both genders and Caucasian, Asian, and African American ethnicities. Performance validation shows promising results: good agreement with the ground truth and well-established physiological precepts. These methods have potential use in the characterization of skin abnormalities and in minimally-invasive prescreening of malignant skin cancers.

  3. Transformation of the rodent malaria parasite Plasmodium chabaudi.

    PubMed

    Spence, Philip J; Cunningham, Deirdre; Jarra, William; Lawton, Jennifer; Langhorne, Jean; Thompson, Joanne

    2011-04-01

    The rodent malaria parasite Plasmodium chabaudi chabaudi shares many features with human malaria species, including P. falciparum, and is the in vivo model of choice for many aspects of malaria research in the mammalian host, from sequestration of parasitized erythrocytes, to antigenic variation and host immunity and immunopathology. This protocol describes an optimized method for the transformation of mature blood-stage P.c. chabaudi and a description of a vector that targets efficient, single crossover integration into the P.c. chabaudi genome. Transformed lines are reproducibly generated and selected within 14-20 d, and show stable long-term protein expression even in the absence of drug selection. This protocol, therefore, provides the scientific community with a robust and reproducible method to generate transformed P.c. chabaudi parasites expressing fluorescent, bioluminescent and model antigens that can be used in vivo to dissect many of the fundamental principles of malaria infection.

  4. Transformation of the rodent malaria parasite Plasmodium chabaudi

    PubMed Central

    Spence, Philip J; Cunningham, Deirdre; Jarra, William; Lawton, Jennifer

    2014-01-01

    The rodent malaria parasite Plasmodium chabaudi chabaudi shares many features with human malaria species, including P. falciparum, and is the in vivo model of choice for many aspects of malaria research in the mammalian host, from sequestration of parasitized erythrocytes, to antigenic variation and host immunity and immunopathology. this protocol describes an optimized method for the transformation of mature blood-stage P.c. chabaudi and a description of a vector that targets efficient, single crossover integration into the P.c. chabaudi genome. Transformed lines are reproducibly generated and selected within 4–20 d, and show stable long-term protein expression even in the absence of drug selection. this protocol, therefore, provides the scientific community with a robust and reproducible method to generate transformed P.c. chabaudi parasites expressing fluorescent, bioluminescent and model antigens that can be used in vivo to dissect many of the fundamental principles of malaria infection. PMID:21455190

  5. In vivo tissue response following implantation of shape memory polyurethane foam in a porcine aneurysm model

    PubMed Central

    Rodriguez, Jennifer N.; Clubb, Fred J.; Wilson, Thomas S.; Miller, Matthew W.; Fossum, Theresa W.; Hartman, Jonathan; Tuzun, Egemen; Singhal, Pooja; Maitland, Duncan J.

    2014-01-01

    Cerebral aneurysms treated by traditional endovascular methods using platinum coils have a tendency to be unstable, either due to chronic inflammation, compaction of coils, or growth of the aneurysm. We propose to use alternate filling methods for the treatment of intracranial aneurysms using polyurethane based shape memory polymer (SMP) foams. SMP polyurethane foams were surgically implanted in a porcine aneurysm model to determine biocompatibility, localized thrombogenicity, and their ability to serve as a stable filler material within an aneurysm. The degree of healing was evaluated via gross observation, histopathology and low vacuum scanning electron microscopy (LV-SEM) imaging after zero, thirty and ninety days. Clotting was initiated within the SMP foam at time zero (less than one hour exposure to blood prior to euthanization), partial healing was observed at thirty days, and almost complete healing had occurred at ninety days in vivo, with minimal inflammatory response. PMID:23650278

  6. In vivo response to an implanted shape memory polyurethane foam in a porcine aneurysm model.

    PubMed

    Rodriguez, Jennifer N; Clubb, Fred J; Wilson, Thomas S; Miller, Matthew W; Fossum, Theresa W; Hartman, Jonathan; Tuzun, Egemen; Singhal, Pooja; Maitland, Duncan J

    2014-05-01

    Cerebral aneurysms treated by traditional endovascular methods using platinum coils have a tendency to be unstable, either due to chronic inflammation, compaction of coils, or growth of the aneurysm. We propose to use alternate filling methods for the treatment of intracranial aneurysms using polyurethane-based shape memory polymer (SMP) foams. SMP polyurethane foams were surgically implanted in a porcine aneurysm model to determine biocompatibility, localized thrombogenicity, and their ability to serve as a stable filler material within an aneurysm. The degree of healing was evaluated via gross observation, histopathology, and low vacuum scanning electron microscopy imaging after 0, 30, and 90 days. Clotting was initiated within the SMP foam at time 0 (<1 h exposure to blood before euthanization), partial healing was observed at 30 days, and almost complete healing had occurred at 90 days in vivo, with minimal inflammatory response. Copyright © 2013 Wiley Periodicals, Inc.

  7. Non-invasive dynamic near-infrared imaging and quantification of vascular leakage in vivo.

    PubMed

    Proulx, Steven T; Luciani, Paola; Alitalo, Annamari; Mumprecht, Viviane; Christiansen, Ailsa J; Huggenberger, Reto; Leroux, Jean-Christophe; Detmar, Michael

    2013-07-01

    Preclinical vascular research has been hindered by a lack of methods that can sensitively image and quantify vascular perfusion and leakage in vivo. In this study, we have developed dynamic near-infrared imaging methods to repeatedly visualize and quantify vascular leakage in mouse skin in vivo, and we have applied these methods to transgenic mice with overexpression of vascular endothelial growth factors VEGF-A or -C. Near-infrared dye conjugates were developed to identify a suitable vascular tracer that had a prolonged circulation lifetime and slow leakage into normal tissue after intravenous injection. Dynamic simultaneous imaging of ear skin and a large blood vessel in the leg enabled determination of the intravascular signal (blood volume fraction) from the tissue signal shortly after injection and quantifications of vascular leakage into the extravascular tissue over time. This method allowed for the sensitive detection of increased blood vascularity and leakage rates in K14-VEGF-A transgenic mice and also reliably measured inflammation-induced changes of vascularity and leakage over time in the same mice. Measurements after injection of recombinant VEGF-A surprisingly revealed increased blood vascular leakage and lymphatic clearance in K14-VEGF-C transgenic mice which have an expanded cutaneous lymphatic vessel network, potentially indicating unanticipated effects of lymphatic drainage on vascular leakage. Increased vascular leakage was also detected in subcutaneous tumors, confirming that the method can also be applied to deeper tissues. This new imaging method might facilitate longitudinal investigations of the in vivo effects of drug candidates, including angiogenesis inhibitors, in preclinical disease models.

  8. Non-invasive dynamic near-infrared imaging and quantification of vascular leakage in vivo

    PubMed Central

    Proulx, Steven T.; Luciani, Paola; Alitalo, Annamari; Mumprecht, Viviane; Christiansen, Ailsa J.; Huggenberger, Reto

    2013-01-01

    Preclinical vascular research has been hindered by a lack of methods that can sensitively image and quantify vascular perfusion and leakage in vivo. In this study, we have developed dynamic near-infrared imaging methods to repeatedly visualize and quantify vascular leakage in mouse skin in vivo, and we have applied these methods to transgenic mice with overexpression of vascular endothelial growth factors VEGF-A or -C. Near-infrared dye conjugates were developed to identify a suitable vascular tracer that had a prolonged circulation lifetime and slow leakage into normal tissue after intravenous injection. Dynamic simultaneous imaging of ear skin and a large blood vessel in the leg enabled determination of the intravascular signal (blood volume fraction) from the tissue signal shortly after injection and quantifications of vascular leakage into the extravascular tissue over time. This method allowed for the sensitive detection of increased blood vascularity and leakage rates in K14-VEGF-A transgenic mice and also reliably measured inflammation-induced changes of vascularity and leakage over time in the same mice. Measurements after injection of recombinant VEGF-A surprisingly revealed increased blood vascular leakage and lymphatic clearance in K14-VEGF-C transgenic mice which have an expanded cutaneous lymphatic vessel network, potentially indicating unanticipated effects of lymphatic drainage on vascular leakage. Increased vascular leakage was also detected in subcutaneous tumors, confirming that the method can also be applied to deeper tissues. This new imaging method might facilitate longitudinal investigations of the in vivo effects of drug candidates, including angiogenesis inhibitors, in preclinical disease models. PMID:23325334

  9. A quantitative systems pharmacology model of blood coagulation network describes in vivo biomarker changes in non-bleeding subjects.

    PubMed

    Lee, D; Nayak, S; Martin, S W; Heatherington, A C; Vicini, P; Hua, F

    2016-12-01

    Essentials Baseline coagulation activity can be detected in non-bleeding state by in vivo biomarker levels. A detailed mathematical model of coagulation was developed to describe the non-bleeding state. Optimized model described in vivo biomarkers with recombinant activated factor VII treatment. Sensitivity analysis predicted prothrombin fragment 1 + 2 and D-dimer are regulated differently. Background Prothrombin fragment 1 + 2 (F 1 + 2 ), thrombin-antithrombin III complex (TAT) and D-dimer can be detected in plasma from non-bleeding hemostatically normal subjects or hemophilic patients. They are often used as safety or pharmacodynamic biomarkers for hemostatis-modulating therapies in the clinic, and provide insights into in vivo coagulation activity. Objectives To develop a quantitative systems pharmacology (QSP) model of the blood coagulation network to describe in vivo biomarkers, including F 1 + 2 , TAT, and D-dimer, under non-bleeding conditions. Methods The QSP model included intrinsic and extrinsic coagulation pathways, platelet activation state-dependent kinetics, and a two-compartment pharmacokinetics model for recombinant activated factor VII (rFVIIa). Literature data on F 1 + 2 and D-dimer at baseline and changes with rFVIIa treatment were used for parameter optimization. Multiparametric sensitivity analysis (MPSA) was used to understand key proteins that regulate F 1 + 2 , TAT and D-dimer levels. Results The model was able to describe tissue factor (TF)-dependent baseline levels of F 1 + 2 , TAT and D-dimer in a non-bleeding state, and their increases in hemostatically normal subjects and hemophilic patients treated with different doses of rFVIIa. The amount of TF required is predicted to be very low in a non-bleeding state. The model also predicts that these biomarker levels will be similar in hemostatically normal subjects and hemophilic patients. MPSA revealed that F 1 + 2 and TAT levels are highly correlated, and that D-dimer is more sensitive to the perturbation of coagulation protein concentrations. Conclusions A QSP model for non-bleeding baseline coagulation activity was established with data from clinically relevant in vivo biomarkers at baseline and changes in response to rFVIIa treatment. This model will provide future mechanistic insights into this system. © 2016 International Society on Thrombosis and Haemostasis.

  10. An in vivo multiplexed small molecule screening platform

    PubMed Central

    Yang, Dian; Ogasawara, Daisuke; Dix, Melissa M.; Rogers, Zoë N.; Chuang, Chen-Hua; McFarland, Christopher D.; Chiou, Shin-Heng; Brown, J. Mark; Cravatt, Benjamin F.; Bogyo, Matthew; Winslow, Monte M.

    2016-01-01

    Phenotype-based small molecule screening is a powerful method to identify regulators of cellular function. However, such screens are generally performed in vitro using conditions that do not necessarily model complex physiological conditions or disease states. Here, we use molecular cell barcoding to enable direct in vivo phenotypic screening of libraries of small molecules. The multiplexed nature of this approach allows rapid in vivo analysis of hundreds to thousands of compounds. Using this platform, we screened >700 covalent inhibitors directed towards hydrolases for their effect on pancreatic cancer metastatic seeding. We identified multiple hits and confirmed the relevant target of one compound as the lipase ABHD6. Pharmacological and genetic studies confirmed the role of this enzyme as a regulator of metastatic fitness. Our results highlight the applicability of this multiplexed screening platform for investigating complex processes in vivo. PMID:27617390

  11. In Vitro versus In Vivo Phase Instability of Zirconia-Toughened Alumina Femoral Heads: A Critical Comparative Assessment

    PubMed Central

    Pezzotti, Giuseppe; Affatato, Saverio; Rondinella, Alfredo; Yorifuji, Makiko; Marin, Elia; Zhu, Wenliang; McEntire, Bryan; Bal, Sonny B.; Yamamoto, Kengo

    2017-01-01

    A clear discrepancy between predicted in vitro and actual in vivo surface phase stability of BIOLOX®delta zirconia-toughened alumina (ZTA) femoral heads has been demonstrated by several independent research groups. Data from retrievals challenge the validity of the standard method currently utilized in evaluating surface stability and raise a series of important questions: (1) Why do in vitro hydrothermal aging treatments conspicuously fail to model actual results from the in vivo environment? (2) What is the preponderant microscopic phenomenon triggering the accelerated transformation in vivo? (3) Ultimately, what revisions of the current in vitro standard are needed in order to obtain consistent predictions of ZTA transformation kinetics in vivo? Reported in this paper is a new in toto method for visualizing the surface stability of femoral heads. It is based on CAD-assisted Raman spectroscopy to quantitatively assess the phase transformation observed in ZTA retrievals. Using a series of independent analytical probes, an evaluation of the microscopic mechanisms responsible for the polymorphic transformation is also provided. An outline is given of the possible ways in which the current hydrothermal simulation standard for artificial joints can be improved in an attempt to reduce the gap between in vitro simulation and reality. PMID:28772828

  12. In Vitro, In Vivo and Post Explantation Testing of Glucose-Detecting Biosensors: Current Methods and Recommendations

    PubMed Central

    Koschwanez, Heidi E.; Reichert, W. Monty

    2007-01-01

    To date, there have been a number of cases where glucose sensors have performed well over long periods of implantation; however, it remains difficult to predict whether a given sensor will perform reliably, will exhibit gradual degradation of performance, or will fail outright soon after implantation. Typically, the literature emphasizes the sensor that performed well, while only briefly (if at all) mentioning the failed devices. This leaves open the question of whether current sensor designs are adequate for the hostile in vivo environment, and whether these sensors have been assessed by the proper regimen of testing protocols. This paper reviews the current in vitro and in vivo testing procedures used to evaluate the functionality and biocompatibility of implantable glucose sensors. An overview of the standards and regulatory bodies that govern biomaterials and end-product device testing precedes a discussion of up-to-date invasive and non-invasive technologies for diabetes management. Analysis of current in vitro, in vivo, and then post implantation testing is presented. Given the underlying assumption that the success of the sensor in vivo foreshadows the long-term reliability of the sensor in the human body, the relative merits of these testing methods are evaluated with respect to how representative they are of human models. PMID:17524479

  13. Tracking of Engineered Bacteria In Vivo Using Nonstandard Amino Acid Incorporation.

    PubMed

    Praveschotinunt, Pichet; Dorval Courchesne, Noémie-Manuelle; den Hartog, Ilona; Lu, Chaochen; Kim, Jessica J; Nguyen, Peter Q; Joshi, Neel S

    2018-06-15

    The rapidly growing field of microbiome research presents a need for better methods of monitoring gut microbes in vivo with high spatial and temporal resolution. We report a method of tracking microbes in vivo within the gastrointestinal tract by programming them to incorporate nonstandard amino acids (NSAA) and labeling them via click chemistry. Using established machinery constituting an orthogonal translation system (OTS), we engineered Escherichia coli to incorporate p-azido-l-phenylalanine (pAzF) in place of the UAG (amber) stop codon. We also introduced a mutant gene encoding for a cell surface protein (CsgA) that was altered to contain an in-frame UAG codon. After pAzF incorporation and extracellular display, the engineered strains could be covalently labeled via copper-free click reaction with a Cy5 dye conjugated to the dibenzocyclooctyl (DBCO) group. We confirmed the functionality of the labeling strategy in vivo using a murine model. Labeling of the engineered strain could be observed using oral administration of the dye to mice several days after colonization of the gastrointestinal tract. This work sets the foundation for the development of in vivo tracking microbial strategies that may be compatible with noninvasive imaging modalities and are capable of longitudinal spatiotemporal monitoring of specific microbial populations.

  14. A comparative study of the chondrogenic potential between synthetic and natural scaffolds in an in vivo bioreactor

    NASA Astrophysics Data System (ADS)

    Huang, Jung-Ju; Yang, Shu-Rui; Chu, I.-Ming; Brey, Eric M.; Hsiao, Hui-Yi; Cheng, Ming-Huei

    2013-10-01

    The clinical demand for cartilage tissue engineering is potentially large for reconstruction defects resulting from congenital deformities or degenerative disease due to limited donor sites for autologous tissue and donor site morbidities. Cartilage tissue engineering has been successfully applied to the medical field: a scaffold pre-cultured with chondrocytes was used prior to implantation in an animal model. We have developed a surgical approach in which tissues are engineered by implantation with a vascular pedicle as an in vivo bioreactor in bone and adipose tissue engineering. Collagen type II, chitosan, poly(lactic-co-glycolic acid) (PLGA) and polycaprolactone (PCL) were four commonly applied scaffolds in cartilage tissue engineering. To expand the application of the same animal model in cartilage tissue engineering, these four scaffolds were selected and compared for their ability to generate cartilage with chondrocytes in the same model with an in vivo bioreactor. Gene expression and immunohistochemistry staining methods were used to evaluate the chondrogenesis and osteogenesis of specimens. The result showed that the PLGA and PCL scaffolds exhibited better chondrogenesis than chitosan and type II collagen in the in vivo bioreactor. Among these four scaffolds, the PCL scaffold presented the most significant result of chondrogenesis embedded around the vascular pedicle in the long-term culture incubation phase.

  15. Spectral Remittance and Transmittance of Visible and Infrared-A Radiation in Human Skin-Comparison Between in vivo Measurements and Model Calculations.

    PubMed

    Piazena, Helmut; Meffert, Hans; Uebelhack, Ralf

    2017-11-01

    The aim of the study was to assess the interindividual variability of spectral remittance and spectral transmittance of visible and infrared-A radiations interacting with human skin and subcutaneous tissue, and direct measurements were taken in vivo using healthy persons of different skin color types. Up to wavelengths of about 900 nm, both spectral remittance and spectral transmittance depended significantly on the individual contents of melanin and hemoglobin in the skin, whereas the contents of water and lipids mainly determined spectral slopes of both characteristics of interaction for wavelengths above about 900 nm. In vivo measured data of spectral transmittance showed approximately similar decreases with tissue thickness between about 900 nm and 1100 nm as compared with model data which were calculated using spectral absorption and scattering coefficients of skin samples in vitro published by different authors. In addition, in vivo measured data and in vitro-based model calculations of spectral remittance were approximately comparable in this wavelength range. In contrast, systematic but individually varying differences between both methods were found for both spectral remittance and spectral transmittance at wavelengths below about 900 nm, where interaction of radiation was significantly affected by both melanin and hemoglobin. © 2017 The American Society of Photobiology.

  16. Application of a Physiologically Based Pharmacokinetic Model to Assess Propofol Hepatic and Renal Glucuronidation in Isolation: Utility of In Vitro and In Vivo Data

    PubMed Central

    Gill, Katherine L.; Gertz, Michael; Houston, J. Brian

    2013-01-01

    A physiologically based pharmacokinetic (PBPK) modeling approach was used to assess the prediction accuracy of propofol hepatic and extrahepatic metabolic clearance and to address previously reported underprediction of in vivo clearance based on static in vitro–in vivo extrapolation methods. The predictive capacity of propofol intrinsic clearance data (CLint) obtained in human hepatocytes and liver and kidney microsomes was assessed using the PBPK model developed in MATLAB software. Microsomal data obtained by both substrate depletion and metabolite formation methods and in the presence of 2% bovine serum albumin were considered in the analysis. Incorporation of hepatic and renal in vitro metabolic clearance in the PBPK model resulted in underprediction of propofol clearance regardless of the source of in vitro data; the predicted value did not exceed 35% of the observed clearance. Subsequently, propofol clinical data from three dose levels in intact patients and anhepatic subjects were used for the optimization of hepatic and renal CLint in a simultaneous fitting routine. Optimization process highlighted that renal glucuronidation clearance was underpredicted to a greater extent than liver clearance, requiring empirical scaling factors of 17 and 9, respectively. The use of optimized clearance parameters predicted hepatic and renal extraction ratios within 20% of the observed values, reported in an additional independent clinical study. This study highlights the complexity involved in assessing the contribution of extrahepatic clearance mechanisms and illustrates the application of PBPK modeling, in conjunction with clinical data, to assess prediction of clearance from in vitro data for each tissue individually. PMID:23303442

  17. Ex Vivo Methods for Informing Computational Models of the Mitral Valve

    PubMed Central

    Bloodworth, Charles H.; Pierce, Eric L.; Easley, Thomas F.; Drach, Andrew; Khalighi, Amir H.; Toma, Milan; Jensen, Morten O.; Sacks, Michael S.; Yoganathan, Ajit P.

    2016-01-01

    Computational modeling of the mitral valve (MV) has potential applications for determining optimal MV repair techniques and risk of recurrent mitral regurgitation. Two key concerns for informing these models are (1) sensitivity of model performance to the accuracy of the input geometry, and, (2) acquisition of comprehensive data sets against which the simulation can be validated across clinically relevant geometries. Addressing the first concern, ex vivo micro-computed tomography (microCT) was used to image MVs at high resolution (~40 micron voxel size). Because MVs distorted substantially during static imaging, glutaraldehyde fixation was used prior to microCT. After fixation, MV leaflet distortions were significantly smaller (p<0.005), and detail of the chordal tree was appreciably greater. Addressing the second concern, a left heart simulator was designed to reproduce MV geometric perturbations seen in vivo in functional mitral regurgitation and after subsequent repair, and maintain compatibility with microCT. By permuting individual excised ovine MVs (n=5) through each state (healthy, diseased and repaired), and imaging with microCT in each state, a comprehensive data set was produced. Using this data set, work is ongoing to construct and validate high-fidelity MV biomechanical models. These models will seek to link MV function across clinically relevant states. PMID:27699507

  18. Label-free detection of circulating melanoma cells by in vivo photoacoustic flow cytometry

    NASA Astrophysics Data System (ADS)

    Wang, Xiaoling; Yang, Ping; Liu, Rongrong; Niu, Zhenyu; Suo, Yuanzhen; He, Hao; Gao, Wenyuan; Tang, Shuo; Wei, Xunbin

    2016-03-01

    Melanoma is a malignant tumor of melanocytes. Melanoma cells have high light absorption due to melanin highly contained in melanoma cells. This property is employed for the detection of circulating melanoma cell by in vivo photoacoustic flow cytometry (PAFC), which is based on photoacoustic effect. Compared to in vivo flow cytometry based on fluorescence, PAFC can employ high melanin content of melanoma cells as endogenous biomarkers to detect circulating melanoma cells in vivo. We have developed in vitro experiments to prove the ability of PAFC system of detecting photoacoustic signals from melanoma cells. For in vivo experiments, we have constructed a model of melanoma tumor bearing mice by inoculating highly metastatic murine melanoma cancer cells, B16F10 with subcutaneous injection. PA signals are detected in the blood vessels of mouse ears in vivo. The raw signal detected from target cells often contains some noise caused by electronic devices, such as background noise and thermal noise. We choose the Wavelet denoising method to effectively distinguish the target signal from background noise. Processing in time domain and frequency domain would be combined to analyze the signal after denoising. This algorithm contains time domain filter and frequency transformation. The frequency spectrum image of the signal contains distinctive features that can be used to analyze the property of target cells or particles. The processing methods have a great potential for analyzing signals accurately and rapidly. By counting circulating melanoma cells termly, we obtain the number variation of circulating melanoma cells as melanoma metastasized. Those results show that PAFC is a noninvasive and label-free method to detect melanoma metastases in blood or lymph circulation.

  19. In vivo evaluation of wearable head impact sensors

    PubMed Central

    Wu, Lyndia C.; Nangia, Vaibhav; Bui, Kevin; Hammoor, Bradley; Kurt, Mehmet; Hernandez, Fidel; Kuo, Calvin; Camarillo, David B.

    2015-01-01

    Inertial sensors are commonly used to measure human head motion.(R1–3) Some sensors have been tested with dummy or cadaver experiments with mixed results, and methods to evaluate sensors in vivo are lacking. Here we present an in vivo(R3–10) method using high speed video to test teeth-mounted (mouthguard), soft tissue-mounted (skin patch), and headgear-mounted (skull cap) sensors during 6–13g(R1–20) sagittal soccer head impacts. Sensor coupling to the skull (R1–3) was quantified by displacement from an ear-canal reference. Mouthguard displacements were within video measurement error (<1mm), while the skin patch and skull cap displaced up to 4mm and 13mm from the ear-canal reference, respectively. We used the mouthguard, which had the least displacement from skull (R1–5), as the reference to assess 6-degree-of-freedom skin patch and skull cap measurements. Linear and rotational acceleration magnitudes were over-predicted by both the skin patch (with 120% NRMS error for amag, 290% for αmag(R1–6)) and the skull cap (320% NRMS error for amag, 500% for αmag(R1–6)). Such over-predictions were largely due to out-of-plane motion. To model sensor error, we found that in-plane skin patch acceleration peaks in the anterior-posterior direction could be modeled by an underdamped viscoelastic system. In summary, the mouthguard showed tighter skull coupling than the other sensor mounting approaches(R1–7). Furthermore, the in vivo methods presented are valuable for investigating skull acceleration sensor technologies. PMID:26289941

  20. Foot and mouth disease vaccine strain selection: Current approaches and future perspectives.

    PubMed

    Mahapatra, Mana; Parida, Satya

    2018-06-27

    Lack of cross protection between foot and mouth disease (FMD) virus (FMDV) serotypes as well as incomplete protection between some subtypes of FMDV affect the application of vaccine in the field. Further, the emergence of new variant FMD viruses periodically makes the existing vaccine inefficient. Consequently, periodical vaccine strain selection either by in vivo methods or in vitro methods become an essential requirement to enable utilisation of appropriate and efficient vaccines. Areas covered: Here we describe the cross reactivity of the existing vaccines with the global pool of circulating viruses and the putative selected vaccine strains for targeting protection against the two major circulating serotype O and A FMD viruses for East Africa, the Middle East, South Asia and South East Asia. Expert Commentary: Although in vivo cross protection studies are more appropriate methods for vaccine matching and selection than in vitro neutralisation test or ELISA, in the face of an outbreak both in vivo and in vitro methods of vaccine matching are not easy, and time consuming. The FMDV capsid contains all the immunogenic epitopes, and therefore vaccine strain prediction models using both capsid sequence and serology data will likely replace existing tools in the future.

  1. Development of an in vivo visual robot system with a magnetic anchoring mechanism and a lens cleaning mechanism for laparoendoscopic single-site surgery (LESS).

    PubMed

    Feng, Haibo; Dong, Dinghui; Ma, Tengfei; Zhuang, Jinlei; Fu, Yili; Lv, Yi; Li, Liyi

    2017-12-01

    Surgical robot systems which can significantly improve surgical procedures have been widely used in laparoendoscopic single-site surgery (LESS). For a relative complex surgical procedure, the development of an in vivo visual robot system for LESS can effectively improve the visualization for surgical robot systems. In this work, an in vivo visual robot system with a new mechanism for LESS was investigated. A finite element method (FEM) analysis was carried out to ensure the safety of the in vivo visual robot during the movement, which was the most important concern for surgical purposes. A master-slave control strategy was adopted, in which the control model was established by off-line experiments. The in vivo visual robot system was verified by using a phantom box. The experiment results show that the robot system can successfully realize the expected functionalities and meet the demands of LESS. The experiment results indicate that the in vivo visual robot with high manipulability has great potential in clinical application. Copyright © 2017 John Wiley & Sons, Ltd.

  2. Beneficial effect of Mentha suaveolens essential oil in the treatment of vaginal candidiasis assessed by real-time monitoring of infection

    PubMed Central

    2011-01-01

    Background Vaginal candidiasis is a frequent and common distressing disease affecting up to 75% of the women of fertile age; most of these women have recurrent episodes. Essential oils from aromatic plants have been shown to have antimicrobial and antifungal activities. This study was aimed at assessing the anti-fungal activity of essential oil from Mentha suaveolens (EOMS) in an experimental infection of vaginal candidiasis. Methods The in vitro and in vivo activity of EOMS was assessed. The in vitro activity was evaluated under standard CLSI methods, and the in vivo analysis was carried out by exploiting a novel, non-invasive model of vaginal candidiasis in mice based on an in vivo imaging technique. Differences between essential oil treated and saline treated mice were evaluated by the non-parametric Mann-Whitney U-test. Viable count data from a time kill assay and yeast and hyphae survival test were compared using the Student's t-test (two-tailed). Results Our main findings were: i) EOMS shows potent candidastatic and candidacidal activity in an in vitro experimental system; ii) EOMS gives a degree of protection against vaginal candidiasis in an in vivo experimental system. Conclusions This study shows for the first time that the essential oil of a Moroccan plant Mentha suaveolens is candidastatic and candidacidal in vitro, and has a degree of anticandidal activity in a model of vaginal infection, as demonstrated in an in vivo monitoring imaging system. We conclude that our findings lay the ground for further, more extensive investigations to identify the active EOMS component(s), promising in the therapeutically problematic setting of chronic vaginal candidiasis in humans. PMID:21356078

  3. On the reliability of the holographic method for measurement of soft tissue modifications during periodontal therapy

    NASA Astrophysics Data System (ADS)

    Stratul, Stefan-Ioan; Sinescu, Cosmin; Negrutiu, Meda; de Sabata, Aldo; Rominu, Mihai; Ogodescu, Alexandru; Rusu, Darian

    2014-01-01

    Holographic evaluations count among recent measurement tools in orthodontics and prosthodontics. This research introduces holography as an assessment method of 3D variations of gingival retractions. The retraction of gingiva on frontal regions of 5 patients with periodontitis was measured in six points and was evaluated by holographic methods using a He-Ne laser device (1mV, Superlum, Carrigtwohill, Ireland) inside a holographic bank of 200 x 100cm. Impressions were taken during first visit and cast models were manufactured. Six months after the end of periodontal treatment, clinical measurements were repeated and the hologram of the first model was superimposed on a final model cast, by using reference points, while maintaining the optical geometric perimeters. The retractions were evaluated 3D in every point using a dedicated software (Sigma Scan Pro,Systat Software, SanJose, CA, USA). The Wilcoxon test was used to compare the mean recession changes between baseline and six months after treatment, and between values in vivo and the values on hologram. No statistically significant differences between values in vivo and on the hologram were found. In conclusion, holography provides a valuable tool for assessing gingival retractions on virtual models. The data can be stored, reproduced, transmitted and compared at a later time point with accuracy.

  4. Development of a Physiologically Based Pharmacokinetic Model for Sinogliatin, a First-in-Class Glucokinase Activator, by Integrating Allometric Scaling, In Vitro to In Vivo Exploration and Steady-State Concentration-Mean Residence Time Methods: Mechanistic Understanding of its Pharmacokinetics.

    PubMed

    Song, Ling; Zhang, Yi; Jiang, Ji; Ren, Shuang; Chen, Li; Liu, Dongyang; Chen, Xijing; Hu, Pei

    2018-04-06

    The objective of this study was to develop a physiologically based pharmacokinetic (PBPK) model for sinogliatin (HMS-5552, dorzagliatin) by integrating allometric scaling (AS), in vitro to in vivo exploration (IVIVE), and steady-state concentration-mean residence time (C ss -MRT) methods and to provide mechanistic insight into its pharmacokinetic properties in humans. Human major pharmacokinetic parameters were analyzed using AS, IVIVE, and C ss -MRT methods with available preclinical in vitro and in vivo data to understand sinogliatin drug metabolism and pharmacokinetic (DMPK) characteristics and underlying mechanisms. On this basis, an initial mechanistic PBPK model of sinogliatin was developed. The initial PBPK model was verified using observed data from a single ascending dose (SAD) study and further optimized with various strategies. The final model was validated by simulating sinogliatin pharmacokinetics under a fed condition. The validated model was applied to support a clinical drug-drug interaction (DDI) study design and to evaluate the effects of intrinsic (hepatic cirrhosis, genetic) factors on drug exposure. The two-species scaling method using rat and dog data (TS- rat,dog ) was the best AS method in predicting human systemic clearance in the central compartment (CL). The IVIVE method confirmed that sinogliatin was predominantly metabolized by cytochrome P450 (CYP) 3A4. The C ss -MRT method suggested dog pharmacokinetic profiles were more similar to human pharmacokinetic profiles. The estimated CL using the AS and IVIVE approaches was within 1.5-fold of that observed. The C ss -MRT method in dogs also provided acceptable prediction of human pharmacokinetic characteristics. For the PBPK approach, the 90% confidence intervals (CIs) of the simulated maximum concentration (C max ), CL, and area under the plasma concentration-time curve (AUC) of sinogliatin were within those observed and the 90% CI of simulated time to C max (t max ) was closed to that observed for a dose range of 5-50 mg in the SAD study. The final PBPK model was validated by simulating sinogliatin pharmacokinetics with food. The 90% CIs of the simulated C max , CL, and AUC values for sinogliatin were within those observed and the 90% CI of the simulated t max was partially within that observed for the dose range of 25-200 mg in the multiple ascending dose (MAD) study. This PBPK model selected a final clinical DDI study design with itraconazole from four potential designs and also evaluated the effects of intrinsic (hepatic cirrhosis, genetic) factors on drug exposure. Sinogliatin pharmacokinetic properties were mechanistically understood by integrating all four methods and a mechanistic PBPK model was successfully developed and validated using clinical data. This PBPK model was applied to support the development of sinogliatin.

  5. Validation of an In Vitro Sun Protection Factor (SPF) method in blinded ring-testing.

    PubMed

    Pissavini, M; Tricaud, C; Wiener, G; Lauer, A; Contier, M; Kolbe, L; Trullás Cabanas, C; Boyer, F; Nollent, V; Meredith, E; Dietrich, E; Matts, P J

    2018-04-20

    The objective of this work was to investigate the utility of a new in vitro SPF test method in blinded ring-testing, against new ISO acceptance criteria. 24 blinded, commercial, emulsion-type, primary sunscreen products, covering the full range of labelled SPF in Europe (SPF6 - 50+), were tested by 3 test institutes using the current ISO24444:2010 In Vivo SPF Test Method and simultaneously by 3 separate test laboratories using a new candidate in vitro SPF test method, developed under the leadership of Cosmetics Europe (CE). The resulting relationship between in vitro SPF and in vivo SPF values was then compared with acceptance criteria developed recently by the International Standards (ISO) TC217 / WG7 Sun Protection Test Methods Working Group. Analysis of the mean inter-laboratory in vitro and mean inter-institute in vivo SPF values revealed a strong correlation between in vitro and in vivo values, with a Pearson correlation coefficient of r 2 =0.88 (p<0.0001), a slope of 1.01 and a non-significant intercept (-1.48; p=0.62). When these data were compared to the new ISO WG7 acceptance criteria, method bias was found to be extremely low and over 95% of the coupled data lay within the model "funnel" (defined by upper and lower confidence intervals). In conclusion, the results of blinded ring testing and comparison to new ISO WG7 acceptance criteria indicate that a new in vitro SPF test method meets (and exceeds) these minimum criteria and is an interesting candidate for possible deployment as an industry test methodology. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  6. Study on the release of fenofibrate nanosuspension in vitro and its correlation with in situ intestinal and in vivo absorption kinetics in rats.

    PubMed

    Xu, Yuanlong; Wang, Yonglu; Li, Xue Ming; Huang, Qinqin; Chen, Wei; Liu, Ran; Chen, BaoAn; Wei, Ping

    2014-07-01

    As an oral delivery carrier for poorly water soluble drugs, the nanosuspension was prepared by melt emulsification method combined with high-pressure homogenization. The objective of this study was to clarify the absorption mechanism in rats of fenofibrate nanosuspension using the model of in situ gut perfusion. The release rate of drug from nanosuspension was fast which about 70% of the drug would be released within 5 minutes. The absorption of fenofibrate nanosuspension in the gastrointestinal (GI) tract was studied by the in situ closed loop method in rats. It was found that the absorption process in intestine was first-process with passive diffusion mechanism, and the whole intestine was the major segment for the drug absorption. Additionally, GI absorption in situ studies indicated that the fenofibrate nanosuspension had great success in regard to enhancement of intestinal absorption compared to the fenofibrate suspension of coarse powder. The pharmacokinetic characteristics were studied in rats after oral administration of fenofibrate nanosuspension or suspension at the dosage of 27 mg/kg. The plasma concentration-time curve was fitted to the one-compartment model. The correlation between in vitro dissolution (P), in situ intestinal absorption (F) and in vivo absorption (Fa) in rats was investigated with the results as follows: Fa = 6.2061P-456.38(r = 0.9559), F = 3.6911P-2.2169(r = 0.970), F = 0.5095P + 44.189(r = 0.9609). The highest level A could be obtained from the in vitro--in vivo correlation (IVIVC) between dissolution percentage and intestinal absorption of the fenofibrate nanosuspension in rats. Consequently, the in situ intestinal perfusion model could be used to predict the in vivo pharmacokinetic characteristics in rats.

  7. The pINDUCER lentiviral toolkit for inducible RNA interference in vitro and in vivo

    PubMed Central

    Meerbrey, Kristen L.; Hu, Guang; Kessler, Jessica D.; Roarty, Kevin; Fang, Justin E.; Herschkowitz, Jason I.; Burrows, Anna E.; Ciccia, Alberto; Sun, Tingting; Schmitt, Earlene M.; Bernardi, Ronald J.; Fu, Xiaoyong; Bland, Christopher S.; Cooper, Thomas A.; Schiff, Rachel; Rosen, Jeffrey M.; Westbrook, Thomas F.; Elledge, Stephen J.

    2011-01-01

    The discovery of RNAi has revolutionized loss-of-function genetic studies in mammalian systems. However, significant challenges still remain to fully exploit RNAi for mammalian genetics. For instance, genetic screens and in vivo studies could be broadly improved by methods that allow inducible and uniform gene expression control. To achieve this, we built the lentiviral pINDUCER series of expression vehicles for inducible RNAi in vivo. Using a multicistronic design, pINDUCER vehicles enable tracking of viral transduction and shRNA or cDNA induction in a broad spectrum of mammalian cell types in vivo. They achieve this uniform temporal, dose-dependent, and reversible control of gene expression across heterogenous cell populations via fluorescence-based quantification of reverse tet-transactivator expression. This feature allows isolation of cell populations that exhibit a potent, inducible target knockdown in vitro and in vivo that can be used in human xenotransplantation models to examine cancer drug targets. PMID:21307310

  8. Probe molecules (PrM) approach in adverse outcome pathway (AOP) based high throughput screening (HTS): in vivo discovery for developing in vitro target methods

    EPA Science Inventory

    Efficient and accurate adverse outcome pathway (AOP) based high-throughput screening (HTS) methods use a systems biology based approach to computationally model in vitro cellular and molecular data for rapid chemical prioritization; however, not all HTS assays are grounded by rel...

  9. Accurate quantification of fluorescent targets within turbid media based on a decoupled fluorescence Monte Carlo model.

    PubMed

    Deng, Yong; Luo, Zhaoyang; Jiang, Xu; Xie, Wenhao; Luo, Qingming

    2015-07-01

    We propose a method based on a decoupled fluorescence Monte Carlo model for constructing fluorescence Jacobians to enable accurate quantification of fluorescence targets within turbid media. The effectiveness of the proposed method is validated using two cylindrical phantoms enclosing fluorescent targets within homogeneous and heterogeneous background media. The results demonstrate that our method can recover relative concentrations of the fluorescent targets with higher accuracy than the perturbation fluorescence Monte Carlo method. This suggests that our method is suitable for quantitative fluorescence diffuse optical tomography, especially for in vivo imaging of fluorophore targets for diagnosis of different diseases and abnormalities.

  10. A simple method for in vivo labelling of infiltrating leukocytes in the mouse retina using indocyanine green dye.

    PubMed

    Sim, Dawn A; Chu, Colin J; Selvam, Senthil; Powner, Michael B; Liyanage, Sidath; Copland, David A; Keane, Pearse A; Tufail, Adnan; Egan, Catherine A; Bainbridge, James W B; Lee, Richard W; Dick, Andrew D; Fruttiger, Marcus

    2015-11-01

    We have developed a method to label and image myeloid cells infiltrating the mouse retina and choroid in vivo, using a single depot injection of indocyanine green dye (ICG). This was demonstrated using the following ocular models of inflammation and angiogenesis: endotoxin-induced uveitis, experimental autoimmune uveoretinitis and laser-induced choroidal neovascularization model. A near-infrared scanning ophthalmoscope was used for in vivo imaging of the eye, and flow cytometry was used on blood and spleen to assess the number and phenotype of labelled cells. ICG was administered 72 h before the induction of inflammation to ensure clearance from the systemic circulation. We found that in vivo intravenous administration failed to label any leukocytes, whereas depot injection, either intraperitoneal or subcutaneous, was successful in labelling leukocytes infiltrating into the retina. Progression of inflammation in the retina could be traced over a period of 14 days following a single depot injection of ICG. Additionally, bright-field microscopy, spectrophotometry and flow cytometric analysis suggest that the predominant population of cells stained by ICG are circulating myeloid cells. The translation of this approach into clinical practice would enable visualization of immune cells in situ. This will not only provide a greater understanding of pathogenesis, monitoring and assessment of therapy in many human ocular diseases but might also open the ability to image immunity live for neurodegenerative disorders, cardiovascular disease and systemic immune-mediated disorders. © 2015. Published by The Company of Biologists Ltd.

  11. In vivo fluorescence imaging of hepatocellular carcinoma using a novel GPC3-specific aptamer probe

    PubMed Central

    Zhao, Menglong; Dong, Lili; Liu, Zhuang; Yang, Shuohui

    2018-01-01

    Background Glypican-3 (GPC3) is highly expressed in most of the hepatocellular carcinomas (HCCs), even in small HCCs. It may be used as a potential biomarker for early detection of HCC. The aptamer is a promising targeting agent with unique advantages over antibody. This study was to introduce a novel GPC3 specific aptamer (AP613-1), to verify its specific binding property in vitro, and to evaluate its targeting efficiency in vivo by performing near-infrared (NIR) fluorescence imaging on an HCC xenograft model. Methods AP613-1 was generated from the systematic evolution of ligands by exponential enrichment. Flow cytometry and aptamer-based immunofluorescence imaging were performed to verify the binding affinity of AP613-1 to GPC3 in vitro. NIR Fluorescence images of nude mice with unilateral (n=12) and bilateral (n=4) subcutaneous xenograft tumors were obtained. Correlation between the tumor fluorescence intensities in vivo and ex vivo was analyzed. Results AP613-1 could specifically bind to GPC3 in vitro. In vivo and ex vivo tumors, fluorescence intensities were in excellent correlation (P<0.001, r=0.968). The fluorescence intensity is significantly higher in tumors given Alexa Fluor 750 (AF750) labeled AP613-1 than in those given AF750 labeled initial ssDNA library both in vivo (P<0.001) and ex vivo (P=0.022). In the mice with bilateral subcutaneous tumors injected with AF750 labeled AP613-1, Huh-7 tumors showed significantly higher fluorescence intensities than A549 tumors both in vivo (P=0.016) and ex vivo (P=0.004). Conclusions AP613-1 displays a specific binding affinity to GPC3 positive HCC. Fluorescently labeled AP613-1 could be used as an imaging probe to subcutaneous HCC in xenograft models. PMID:29675356

  12. Contrast-enhanced CT with a High-Affinity Cationic Contrast Agent for Imaging ex Vivo Bovine, Intact ex Vivo Rabbit, and in Vivo Rabbit Cartilage

    PubMed Central

    Stewart, Rachel C.; Bansal, Prashant N.; Entezari, Vahid; Lusic, Hrvoje; Nazarian, Rosalynn M.; Snyder, Brian D.

    2013-01-01

    Purpose: To quantify the affinity of a cationic computed tomography (CT) contrast agent (CA4+) and that of an anionic contrast agent (ioxaglate) to glycosaminoglycans (GAGs) in ex vivo cartilage tissue explants and to characterize the in vivo diffusion kinetics of CA4+ and ioxaglate in a rabbit model. Materials and Methods: All in vivo procedures were approved by the institutional animal care and use committee. The affinities of ioxaglate and CA4+ to GAGs in cartilage (six bovine osteochondral plugs) were quantified by means of a modified binding assay using micro-CT after plug equilibration in serial dilutions of each agent. The contrast agents were administered intraarticularly to the knee joints of five New Zealand white rabbits to determine the in vivo diffusion kinetics and cartilage tissue imaging capabilities. Kinetics of diffusion into the femoral groove cartilage and relative contrast agent uptake into bovine plugs were characterized by means of nonlinear mixed-effects models. Diffusion time constants (τ) were compared by using a Student t test. Results: The uptake of CA4+ in cartilage was consistently over 100% of the reservoir concentration, whereas it was only 59% for ioxaglate. In vivo, the contrast material–enhanced cartilage reached a steady CT attenuation for both CA4+ and ioxaglate, with τ values of 13.8 and 6.5 minutes, respectively (P = .04). The cartilage was easily distinguishable from the surrounding tissues for CA4+ (12 mg of iodine per milliliter); comparatively, the anionic contrast agent provided less favorable imaging results, even when a higher concentration was used (80 mg of iodine per milliliter). Conclusion: The affinity of the cationic contrast agent CA4+ to GAGs enables high-quality imaging and segmentation of ex vivo bovine and rabbit cartilage, as well as in vivo rabbit cartilage. © RSNA, 2012 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12112246/-/DC1 PMID:23192774

  13. Exploration and comparison of in vitro eye irritation tests with the ISO standard in vivo rabbit test for the evaluation of the ocular irritancy of contact lenses.

    PubMed

    Yun, Jun-Won; Hailian, Quan; Na, Yirang; Kang, Byeong-Cheol; Yoon, Jung-Hee; Cho, Eun-Young; Lee, Miri; Kim, Da-Eun; Bae, SeungJin; Seok, Seung Hyeok; Lim, Kyung-Min

    2016-12-01

    In an effort to explore the use of alternative methods to animal testing for the evaluation of the ocular irritancy of medical devices, we evaluated representative contact lenses with the bovine corneal opacity and permeability test (BCOP) and an in vitro eye irritation test using the three-dimensionally-reconstructed human corneal epithelium (RhCE) models, EpiOcular™ and MCTT HCE™. In addition, we compared the obtained results with the ISO standard in vivo rabbit eye irritation test (ISO10993-10). Along with the positive controls (benzalkonium chloride, BAK, 0.02, 0.2, and 1%), the extracts of 4 representative contact lenses (soft, disposable, hard, and colored lenses) and 2 reference lenses (dye-eluting and BAK-coated lenses) were tested. All the lenses, except for the BAK-coated lens, were determined non-irritants in all test methods, while the positive controls yielded relevant results. More importantly, BCOP, EpiOcular™, and MCTT HCE™ yielded a consistent decision for all the tested samples, with the exception of 0.2% BAK in BCOP, for which no prediction could be made. Overall, all the in vitro tests correlated well with the in vivo rabbit eye irritation test, and furthermore, the combination of in vitro tests as a tiered testing strategy was able to produce results similar to those seen in vivo. These observations suggest that such methods can be used as alternative assays to replace the conventional in vivo test method in the evaluation of the ocular irritancy of ophthalmic medical devices, although further study is necessary. Copyright © 2016. Published by Elsevier Ltd.

  14. Development of an In Vivo and In Vitro Ileal Fermentation Method in a Growing Pig Model.

    PubMed

    Montoya, Carlos A; de Haas, Edward S; Moughan, Paul J

    2018-02-01

    Substantial microbial fermentation may occur mainly in the lower small intestine (SI) of human adults, but there is no established methodology to determine this. The study aimed to develop a combined in vivo and in vitro methodology for ileal fermentation based on the pig as an animal model for digestion in human adults. Several aspects of a combined in vivo/in vitro ileal fermentation assay were evaluated. Male 9-wk-old pigs (n = 30; mean ± SD body weight: 23 ± 1.6 kg) were fed a human-type diet (143, 508, 45, 49, and 116 g/kg dry matter diet of crude protein, starch, total lipid, ash, and total dietary fiber) for 15 d. On day 15, pigs were killed, and the last third of the SI was collected to prepare an ileal digesta-based inoculum. Terminal jejunal digesta (last 50 cm of the second third of the SI) were collected as substrate for the assay to test the form of substrate (fresh or freeze-dried), origin (location in jejunum or SI) of the substrate, storage of the inoculum, incubation time (1.2-6.8 h), pH of the medium, and inoculum concentration (6-26 mg inoculum/100 mg substrate). The group of donor pigs used to prepare the inoculum, form of the substrate, origin of the substrate, origin of the inoculum (location in the SI), storage of the inoculum, incubation time, and inoculum concentration did not influence the in vitro ileal organic matter (OM) fermentability (P > 0.05). The in vitro ileal OM fermentability decreased when the pH of the medium increased from 5.5 to 7.5 (31% to 28%; P ≤ 0.05). Predicted (in vivo/in vitro) apparent ileal OM digestibility was similar to the value measured in vivo. Thirty-percent of the terminal jejunal digesta OM was fermented in the ileum. Fiber fermentation in the ileum can be studied using the optimized in vivo/in vitro ileal fermentation method.

  15. Using Dual Fluorescence Reporting Genes to Establish an In Vivo Imaging Model of Orthotopic Lung Adenocarcinoma in Mice.

    PubMed

    Lai, Cheng-Wei; Chen, Hsiao-Ling; Yen, Chih-Ching; Wang, Jiun-Long; Yang, Shang-Hsun; Chen, Chuan-Mu

    2016-12-01

    Lung adenocarcinoma is characterized by a poor prognosis and high mortality worldwide. In this study, we purposed to use the live imaging techniques and a reporter gene that generates highly penetrative near-infrared (NIR) fluorescence to establish a preclinical animal model that allows in vivo monitoring of lung cancer development and provides a non-invasive tool for the research on lung cancer pathogenesis and therapeutic efficacy. A human lung adenocarcinoma cell line (A549), which stably expressed the dual fluorescence reporting gene (pCAG-iRFP-2A-Venus), was used to generate subcutaneous or orthotopic lung cancer in nude mice. Cancer development was evaluated by live imaging via the NIR fluorescent signals from iRFP, and the signals were verified ex vivo by the green fluorescence of Venus from the gross lung. The tumor-bearing mice received miR-16 nucleic acid therapy by intranasal administration to demonstrate therapeutic efficacy in this live imaging system. For the subcutaneous xenografts, the detection of iRFP fluorescent signals revealed delicate changes occurring during tumor growth that are not distinguishable by conventional methods of tumor measurement. For the orthotopic xenografts, the positive correlation between the in vivo iRFP signal from mice chests and the ex vivo green fluorescent signal from gross lung tumors and the results of the suppressed tumorigenesis by miR-16 treatment indicated that lung tumor size can be accurately quantified by the emission of NIR fluorescence. In addition, orthotopic lung tumor localization can be accurately visualized using iRFP fluorescence tomography in vivo, thus revealing the trafficking of lung tumor cells. We introduced a novel dual fluorescence lung cancer model that provides a non-invasive option for preclinical research via the use of NIR fluorescence in live imaging of lung.

  16. In vivo Loads in the Lumbar L3-4 Disc during a Weight Lifting Extension

    PubMed Central

    Wang, Shaobai; Park, Won Man; Kim, Yoon Hyuk; Cha, Thomas; Wood, Kirkham; Li, Guoan

    2014-01-01

    Background Knowledge of in vivo human lumbar loading is critical for understanding the lumbar function and for improving surgical treatments of lumbar pathology. Although numerous experimental measurements and computational simulations have been reported, non-invasive determination of in vivo spinal disc loads is still a challenge in biomedical engineering. The object of the study is to investigate the in vivo human lumbar disc loads using a subject-specific and kinematic driven finite element approach. Methods Three dimensional (3D) lumbar spine models of three living subjects were created using MR images. A 3D finite element model of the L3-4 disc, including the annulus fibrosus and nucleus pulposus, was built for each subject. The endplate kinematics of the L3-4 segment of each subject during a dynamic weight lifting extension was determined using a dual fluoroscopic imaging technique. The endplate kinematics was used as displacement boundary conditions of the subject specific finite element model of the L3-4 disc to calculate the in-vivo disc forces and moments during the weight lifting activity. Findings During the weight lifting extension, the L3-4 disc experienced maximum shear load of about 230 N or 0.34 bodyweight at the flexion position and maximum compressive load of 1500 N or 2.28 bodyweight at the upright position. The disc experienced a primary flexion-extension moment during the motion which reached a maximum of 4.2 Nm at upright position with stretched arms holding the weight. Interpretation This study provided quantitative data on in vivo disc loading that could help understand intrinsic biomechanics of the spine and improve surgical treatment of pathological discs using fusion or arthroplasty techniques. PMID:24345591

  17. Use of ferrets for electrophysiologic monitoring of ion transport

    PubMed Central

    Kaza, Niroop; Raju, S. Vamsee; Cadillac, Joan M.; Trombley, John A.; Rasmussen, Lawrence; Tang, Liping; Dohm, Erik; Harrod, Kevin S.

    2017-01-01

    Limited success achieved in translating basic science discoveries into clinical applications for chronic airway diseases is attributed to differences in respiratory anatomy and physiology, poor approximation of pathologic processes, and lack of correlative clinical endpoints between humans and laboratory animal models. Here, we discuss advantages of using ferrets (Mustela putorus furo) as a model for improved understanding of human airway physiology and demonstrate assays for quantifying airway epithelial ion transport in vivo and ex vivo, and establish air-liquid interface cultures of ferret airway epithelial cells as a complementary in vitro model for mechanistic studies. We present data here that establishes the feasibility of measuring these human disease endpoints in ferrets. Briefly, potential difference across the nasal and the lower airway epithelium in ferrets could be consistently assessed, were highly reproducible, and responsive to experimental interventions. Additionally, ferret airway epithelial cells were amenable to primary cell culture methods for in vitro experiments as was the use of ferret tracheal explants as an ex vivo system for assessing ion transport. The feasibility of conducting multiple assessments of disease outcomes supports the adoption of ferrets as a highly relevant model for research in obstructive airway diseases. PMID:29077751

  18. Use of ferrets for electrophysiologic monitoring of ion transport.

    PubMed

    Kaza, Niroop; Raju, S Vamsee; Cadillac, Joan M; Trombley, John A; Rasmussen, Lawrence; Tang, Liping; Dohm, Erik; Harrod, Kevin S; Rowe, Steven M

    2017-01-01

    Limited success achieved in translating basic science discoveries into clinical applications for chronic airway diseases is attributed to differences in respiratory anatomy and physiology, poor approximation of pathologic processes, and lack of correlative clinical endpoints between humans and laboratory animal models. Here, we discuss advantages of using ferrets (Mustela putorus furo) as a model for improved understanding of human airway physiology and demonstrate assays for quantifying airway epithelial ion transport in vivo and ex vivo, and establish air-liquid interface cultures of ferret airway epithelial cells as a complementary in vitro model for mechanistic studies. We present data here that establishes the feasibility of measuring these human disease endpoints in ferrets. Briefly, potential difference across the nasal and the lower airway epithelium in ferrets could be consistently assessed, were highly reproducible, and responsive to experimental interventions. Additionally, ferret airway epithelial cells were amenable to primary cell culture methods for in vitro experiments as was the use of ferret tracheal explants as an ex vivo system for assessing ion transport. The feasibility of conducting multiple assessments of disease outcomes supports the adoption of ferrets as a highly relevant model for research in obstructive airway diseases.

  19. Shuttle of lentiviral vectors via transplanted cells in vivo.

    PubMed

    Blömer, U; Gruh, I; Witschel, H; Haverich, A; Martin, U

    2005-01-01

    Lentiviral vectors have turned out to be an efficient method for stable gene transfer in vitro and in vivo. Not only do fields of application include cell marking and tracing following transplantation in vivo, but also the stable delivery of biological active proteins for gene therapy. A variety of cells, however, need immediate transplantation after preparation, for example, to prevent cell death, differentiation or de-differentiation. Although these cells are usually washed several times following lentiviral transduction, there may be the risk of viral vector shuttle via transplanted cells resulting in undesired in vivo transduction of recipient cells. We investigated whether infectious lentiviral particles are transmitted via ex vivo lentivirally transduced cells. To this end, we explored potential viral shuttle via ex vivo lentivirally transduced cardiomyocytes in vitro and following transplantation into the brain and peripheral muscle. We demonstrate that, even after extensive washing, infectious viral vector particles can be detected in cell suspensions. Those lentiviral vector particles were able to transduce target cells in transwell experiments. Moreover, transmitted vector particles stably transduced resident cells of the recipient central nervous system and muscle in vivo. Our results of lentiviral vector shuttle via transduced cardiomyocytes are significant for both ex vivo gene therapy and for lentiviral cell tracing, in particular for investigation of stem cell differentiation in transplantation models and co-cultivation systems.

  20. I Vivo Quantitative Ultrasound Imaging and Scatter Assessments.

    NASA Astrophysics Data System (ADS)

    Lu, Zheng Feng

    There is evidence that "instrument independent" measurements of ultrasonic scattering properties would provide useful diagnostic information that is not available with conventional ultrasound imaging. This dissertation is a continuing effort to test the above hypothesis and to incorporate quantitative ultrasound methods into clinical examinations for early detection of diffuse liver disease. A well-established reference phantom method was employed to construct quantitative ultrasound images of tissue in vivo. The method was verified by extensive phantom tests. A new method was developed to measure the effective attenuation coefficient of the body wall. The method relates the slope of the difference between the echo signal power spectrum from a uniform region distal to the body wall and the echo signal power spectrum from a reference phantom to the body wall attenuation. The accuracy obtained from phantom tests suggests further studies with animal experiments. Clinically, thirty-five healthy subjects and sixteen patients with diffuse liver disease were studied by these quantitative ultrasound methods. The average attenuation coefficient in normals agreed with previous investigators' results; in vivo backscatter coefficients agreed with the results from normals measured by O'Donnell. Strong discriminating power (p < 0.001) was found for both attenuation and backscatter coefficients between fatty livers and normals; a significant difference (p < 0.01) was observed in the backscatter coefficient but not in the attenuation coefficient between cirrhotic livers and normals. An in vivo animal model of steroid hepatopathy was used to investigate the system sensitivity in detecting early changes in canine liver resulting from corticosteroid administration. The average attenuation coefficient slope increased from 0.7 dB/cm/MHz in controls to 0.82 dB/cm/MHz (at 6 MHz) in treated animals on day 14 into the treatment, and the backscatter coefficient was 26times 10^{ -4}cm^{-1}sr^{-1} in controls compared with 74times 10^{-4}cm^{-1}sr^ {-1} (at 6 MHz) in treated animals. A simplified quantitative approach using video image signals was developed. Results derived both from the r.f. signal analysis and from the video signal analysis are sensitive to the changes in the liver in this animal model.

  1. In vivo label-free lymphangiography of cutaneous lymphatic vessels in human burn scars using optical coherence tomography

    PubMed Central

    Gong, Peijun; Es’haghian, Shaghayegh; Harms, Karl-Anton; Murray, Alexandra; Rea, Suzanne; Wood, Fiona M.; Sampson, David D.; McLaughlin, Robert A.

    2016-01-01

    We present an automated, label-free method for lymphangiography of cutaneous lymphatic vessels in humans in vivo using optical coherence tomography (OCT). This method corrects for the variation in OCT signal due to the confocal function and sensitivity fall-off of a spectral-domain OCT system and utilizes a single-scattering model to compensate for A-scan signal attenuation to enable reliable thresholding of lymphatic vessels. A segment-joining algorithm is then incorporated into the method to mitigate partial-volume effects with small vessels. The lymphatic vessel images are augmented with images of the blood vessel network, acquired from the speckle decorrelation with additional weighting to differentiate blood vessels from the observed high decorrelation in lymphatic vessels. We demonstrate the method with longitudinal scans of human burn scar patients undergoing ablative fractional laser treatment, showing the visualization of the cutaneous lymphatic and blood vessel networks. PMID:28018713

  2. Genetically Engineered Humanized Mouse Models for Preclinical Antibody Studies

    PubMed Central

    Proetzel, Gabriele; Wiles, Michael V.; Roopenian, Derry C.

    2015-01-01

    The use of genetic engineering has vastly improved our capabilities to create animal models relevant in preclinical research. With the recent advances in gene-editing technologies, it is now possible to very rapidly create highly tunable mouse models as needs arise. Here, we provide an overview of genetic engineering methods, as well as the development of humanized neonatal Fc receptor (FcRn) models and their use for monoclonal antibody in vivo studies. PMID:24150980

  3. In vitro and in vivo evaluation of the bioactivity of hydroxyapatite-coated polyetheretherketone biocomposites created by cold spray technology.

    PubMed

    Lee, Jae Hyup; Jang, Hae Lin; Lee, Kyung Mee; Baek, Hae-Ri; Jin, Kyoungsuk; Hong, Kug Sun; Noh, Jun Hong; Lee, Hyun-Kyung

    2013-04-01

    Polyetheretherketone (PEEK) is a material that is widely used in medicine because its mechanical properties show excellent similarity to those of human bone. However, because it is bioinert, PEEK shows limited ability to bind to natural bone tissue. Here, we applied a cold spray method to make a hydroxyapatite (HA)-coated PEEK hybrid material and evaluated its osteointegration in vitro and in vivo. With the cold spray method, the HA coating formed a homogeneous layer and adhered strongly to the PEEK disk implant. When the material was tested in vitro, early cell adhesion and viability improved. Alkaline phosphatase (ALP) activity and calcium concentration were also higher in cells cultured on HA-coated PEEK disks. In addition, the expression of osteoblast differentiation markers, such as ALP, bone sialoprotein and runt-related transcription factor 2, increased in these cells. For the in vivo test, we designed and implanted HA-coated PEEK cylinders into a rabbit ilium model by the press-fit method. The bone-implant contact ratio, trabecular number and trabecular thickness were determined using either three-dimensional microcomputed tomography or general two-dimensional histomorphometric analysis. This report demonstrates that the HA coating on the PEEK implant added with the cold spray method increased biocompatibility in vitro and promoted osteointegration in vivo, which suggests that the HA coating may improve the biofunctionality of various medical devices used in clinical applications. Copyright © 2012 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  4. In vivo quantitative magnetization transfer imaging correlates with histology during de- and remyelination in cuprizone-treated mice.

    PubMed

    Turati, Laura; Moscatelli, Marco; Mastropietro, Alfonso; Dowell, Nicholas G; Zucca, Ileana; Erbetta, Alessandra; Cordiglieri, Chiara; Brenna, Greta; Bianchi, Beatrice; Mantegazza, Renato; Cercignani, Mara; Baggi, Fulvio; Minati, Ludovico

    2015-03-01

    The pool size ratio measured by quantitative magnetization transfer MRI is hypothesized to closely reflect myelin density, but their relationship has so far been confirmed mostly in ex vivo conditions. We investigate the correspondence between this parameter measured in vivo at 7.0 T, with Black Gold II staining for myelin fibres, and with myelin basic protein and beta-tubulin immunofluorescence in a hybrid longitudinal study of C57BL/6 and SJL/J mice treated with cuprizone, a neurotoxicant causing relatively selective myelin loss followed by spontaneous remyelination upon treatment suspension. Our results confirm that pool size ratio measurements correlate with myelin content, with the correlation coefficient depending on strain and staining method, and demonstrate the in vivo applicability of this MRI technique to experimental mouse models of multiple sclerosis. Copyright © 2015 John Wiley & Sons, Ltd.

  5. Phototoxicity to sulphonamide-derived oral antidiabetics and diuretics: comparative in-vitro and in-vivo investigations

    NASA Astrophysics Data System (ADS)

    Selvaag, Edgar; Anholt, Helle; Moan, Johan; Thune, Per

    1997-12-01

    Seven oral antidiabetics (chlorpropamide, glibenclamide, glipizide, gliquidone, glymidine, tolazamide, and tolbutamide), and 14 diuretics (bemetizide, bendroflumethiazide, benzylhydrochlorothiazide, bumetanide, butizide, chlortalidone, furosemide, hydrochlorothiazide, hydroflumethiazide, indapamide, piretanide, polythiazide, trichlormethiazide, and xipamide) were investigated for potential phototoxicity in vitro using a cell culture model and in vivo in hairless mice. After exposure to broad band UVA, the majority of the substances tested in vitro yielded phototoxic action leading to loss of culture forming ability. In vivo, all tested substances induced edema or ulceration, and lead to a significant increase in skin fold thickness of the mouse skin. In all a number of substances not described to induce clinical photosensitivity nor phototoxicity in vitro or in vivo were detected in our testing. In determining potential photosensitizers, it seems important to utilize different test methods, as not all substances will exhibit action in a given assay.

  6. Efficient monitoring of the blood-stage infection in a malaria rodent model by the rotating-crystal magneto-optical method

    NASA Astrophysics Data System (ADS)

    Orbán, Ágnes; Rebelo, Maria; Molnár, Petra; Albuquerque, Inês S.; Butykai, Adam; Kézsmárki, István

    2016-03-01

    Intense research efforts have been focused on the improvement of the efficiency and sensitivity of malaria diagnostics, especially in resource-limited settings for the detection of asymptomatic infections. Our recently developed magneto-optical (MO) method allows the accurate quantification of malaria pigment crystals (hemozoin) in blood by their magnetically induced rotation. First evaluations of the method using β-hematin crystals and in vitro P. falciparum cultures implied its potential for high-sensitivity malaria diagnosis. To further investigate this potential, here we study the performance of the method in monitoring the in vivo onset and progression of the blood-stage infection in a rodent malaria model. Our results show that the MO method can detect the first generation of intraerythrocytic P. berghei parasites 66-76 hours after sporozoite injection, demonstrating similar sensitivity to Giesma-stained light microscopy and exceeding that of flow cytometric techniques. Magneto-optical measurements performed during and after the treatment of P. berghei infections revealed that both the follow up under treatment and the detection of later reinfections are feasible with this new technique. The present study demonstrates that the MO method - besides being label and reagent-free, automated and rapid - has a high in vivo sensitivity and is ready for in-field evaluation.

  7. Evaluation of Pharmacokinetic Assumptions Using a 443 ...

    EPA Pesticide Factsheets

    With the increasing availability of high-throughput and in vitro data for untested chemicals, there is a need for pharmacokinetic (PK) models for in vitro to in vivo extrapolation (IVIVE). Though some PBPK models have been created for individual compounds using in vivo data, we are now able to rapidly parameterize generic PBPK models using in vitro data to allow IVIVE for chemicals tested for bioactivity via high-throughput screening. However, these new models are expected to have limited accuracy due to their simplicity and generalization of assumptions. We evaluated the assumptions and performance of a generic PBPK model (R package “httk”) parameterized by a library of in vitro PK data for 443 chemicals. We evaluate and calibrate Schmitt’s method by comparing the predicted volume of distribution (Vd) and tissue partition coefficients to in vivo measurements. The partition coefficients are initially over predicted, likely due to overestimation of partitioning into phospholipids in tissues and the lack of lipid partitioning in the in vitro measurements of the fraction unbound in plasma. Correcting for phospholipids and plasma binding improved the predictive ability (R2 to 0.52 for partition coefficients and 0.32 for Vd). We lacked enough data to evaluate the accuracy of changing the model structure to include tissue blood volumes and/or separate compartments for richly/poorly perfused tissues, therefore we evaluated the impact of these changes on model

  8. Susceptibility weighted imaging of cartilage canals in porcine epiphyseal growth cartilage ex vivo and in vivo.

    PubMed

    Nissi, Mikko J; Toth, Ferenc; Zhang, Jinjin; Schmitter, Sebastian; Benson, Michael; Carlson, Cathy S; Ellermann, Jutta M

    2014-06-01

    High-resolution visualization of cartilage canals has been restricted to histological methods and contrast-enhanced imaging. In this study, the feasibility of non-contrast-enhanced susceptibility weighted imaging (SWI) for visualization of the cartilage canals was investigated ex vivo at 9.4 T, further explored at 7 and 3 T and demonstrated in vivo at 7 T, using a porcine animal model. SWI scans of specimens of distal femur and humerus from 1 to 8 week-old piglets were conducted at 9.4 T using 3D-GRE sequence and SWI post-processing. The stifle joints of a 2-week old piglet were scanned ex vivo at 7 and 3 T. Finally, the same sites of a 3-week-old piglet were scanned, in vivo, at 7 T under general anesthesia using the vendor-provided sequences. High-contrast visualization of the cartilage canals was obtained ex vivo, especially at higher field strengths; the results were confirmed histologically. In vivo feasibility was demonstrated at 7 T and comparison of ex vivo scans at 3 and 7 T indicated feasibility of using SWI at 3 T. High-resolution 3D visualization of cartilage canals was demonstrated using SWI. This demonstration of fully noninvasive visualization opens new avenues to explore skeletal maturation and the role of vascular supply for diseases such as osteochondrosis. Copyright © 2013 Wiley Periodicals, Inc.

  9. 31P-Magnetization Transfer Magnetic Resonance Spectroscopy Measurements of In Vivo Metabolism

    PubMed Central

    Befroy, Douglas E.; Rothman, Douglas L.; Petersen, Kitt Falk; Shulman, Gerald I.

    2012-01-01

    Magnetic resonance spectroscopy offers a broad range of noninvasive analytical methods for investigating metabolism in vivo. Of these, the magnetization-transfer (MT) techniques permit the estimation of the unidirectional fluxes associated with metabolic exchange reactions. Phosphorus (31P) MT measurements can be used to examine the bioenergetic reactions of the creatine-kinase system and the ATP synthesis/hydrolysis cycle. Observations from our group and others suggest that the inorganic phosphate (Pi) → ATP flux in skeletal muscle may be modulated by certain conditions, including aging, insulin resistance, and diabetes, and may reflect inherent alterations in mitochondrial metabolism. However, such effects on the Pi → ATP flux are not universally observed under conditions in which mitochondrial function, assessed by other techniques, is impaired, and recent articles have raised concerns about the absolute magnitude of the measured reaction rates. As the application of 31P-MT techniques becomes more widespread, this article reviews the methodology and outlines our experience with its implementation in a variety of models in vivo. Also discussed are potential limitations of the technique, complementary methods for assessing oxidative metabolism, and whether the Pi → ATP flux is a viable biomarker of metabolic function in vivo. PMID:23093656

  10. Novel In Vivo Model for Combinatorial Fluorescence Labeling in Mouse Prostate

    PubMed Central

    Fang, Xiaolan; Gyabaah, Kenneth; Nickkholgh, Bita; Cline, J. Mark; Balaji, K.C.

    2015-01-01

    BACKGROUND The epithelial layer of prostate glands contains several types of cells, including luminal and basal cells. Yet there is paucity of animal models to study the cellular origin of normal or neoplastic development in the prostate to facilitate the treatment of heterogenous prostate diseases by targeting individual cell lineages. METHODS We developed a mouse model that expresses different types of fluorescent proteins (XFPs) specifically in prostatic cells. Using an in vivo stochastic fluorescent protein combinatorial strategy, XFP signals were expressed specifically in prostate of Protein Kinase D1 (PKD1) knock-out, K-RasG12D knock-in, and Phosphatase and tensin homolog (PTEN) and PKD1 double knock-out mice under the control of PB-Cre promoter. RESULTS In vivo XFP signals were observed in prostate of PKD1 knock-out, K-RasG12D knock-in, and PTEN PKD1 double knock-out mice, which developed normal, hyperplastic, and neoplastic prostate, respectively. The patchy expression pattern of XFPs in neoplasia tissue indicated the clonal origin of cancer cells in the prostate. CONCLUSIONS The transgenic mouse models demonstrate combinatorial fluorescent protein expression in normal and cancerous prostatic tissues. This novel prostate-specific fluorescent labeled mouse model, which we named Prorainbow, could be useful in studying benign and malignant pathology of prostate. PMID:25753731

  11. Development and validation of in vitro-in vivo correlation (IVIVC) for estradiol transdermal drug delivery systems.

    PubMed

    Yang, Yang; Manda, Prashanth; Pavurala, Naresh; Khan, Mansoor A; Krishnaiah, Yellela S R

    2015-07-28

    The objective of this study was to develop a level A in vitro-in vivo correlation (IVIVC) for drug-in-adhesive (DIA) type estradiol transdermal drug delivery systems (TDDS). In vitro drug permeation studies across human skin were carried out to obtain the percent of estradiol permeation from marketed products. The in vivo time versus plasma concentration data of three estradiol TDDS at drug loadings of 2.0, 3.8 and 7.6mg (delivery rates of 25, 50 and 100μg/day, respectively) was deconvoluted using Wagner-Nelson method to obtain percent of in vivo drug absorption in postmenopausal women. The IVIVC between the in vitro percent of drug permeation (X) and in vivo percent of drug absorption (Y) for these three estradiol TDDS was constructed using GastroPlus® software. There was a high correlation (R(2)=1.0) with a polynomial regression of Y=-0.227X(2)+0.331X-0.001. These three estradiol TDDS were used for internal validation whereas another two products of the same formulation design (with delivery rates of 60 and 100μg/day) were used for external validation. The predicted estradiol serum concentrations (convoluted from in vitro skin permeation data) were compared with the observed serum concentrations for the respective products. The developed IVIVC model passed both the internal and external validations as the prediction errors (%PE) for Cmax and AUC were less than 15%. When another marketed estradiol TDDS with a delivery rate of 100μg/day but with a slight variation in formulation design was chosen, it did not pass external validation indicating the product-specific nature of IVIVC model. Results suggest that the IVIVC model developed in this study can be used to successfully predict the in vivo performance of the same estradiol TDDS with in vivo delivery rates ranging from 25 to 100μg/day. Published by Elsevier B.V.

  12. Simultaneous prediction of muscle and contact forces in the knee during gait.

    PubMed

    Lin, Yi-Chung; Walter, Jonathan P; Banks, Scott A; Pandy, Marcus G; Fregly, Benjamin J

    2010-03-22

    Musculoskeletal models are currently the primary means for estimating in vivo muscle and contact forces in the knee during gait. These models typically couple a dynamic skeletal model with individual muscle models but rarely include articular contact models due to their high computational cost. This study evaluates a novel method for predicting muscle and contact forces simultaneously in the knee during gait. The method utilizes a 12 degree-of-freedom knee model (femur, tibia, and patella) combining muscle, articular contact, and dynamic skeletal models. Eight static optimization problems were formulated using two cost functions (one based on muscle activations and one based on contact forces) and four constraints sets (each composed of different combinations of inverse dynamic loads). The estimated muscle and contact forces were evaluated using in vivo tibial contact force data collected from a patient with a force-measuring knee implant. When the eight optimization problems were solved with added constraints to match the in vivo contact force measurements, root-mean-square errors in predicted contact forces were less than 10 N. Furthermore, muscle and patellar contact forces predicted by the two cost functions became more similar as more inverse dynamic loads were used as constraints. When the contact force constraints were removed, estimated medial contact forces were similar and lateral contact forces lower in magnitude compared to measured contact forces, with estimated muscle forces being sensitive and estimated patellar contact forces relatively insensitive to the choice of cost function and constraint set. These results suggest that optimization problem formulation coupled with knee model complexity can significantly affect predicted muscle and contact forces in the knee during gait. Further research using a complete lower limb model is needed to assess the importance of this finding to the muscle and contact force estimation process. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  13. In vivo and in silico dynamics of the development of Metabolic Syndrome.

    PubMed

    Rozendaal, Yvonne J W; Wang, Yanan; Paalvast, Yared; Tambyrajah, Lauren L; Li, Zhuang; Willems van Dijk, Ko; Rensen, Patrick C N; Kuivenhoven, Jan A; Groen, Albert K; Hilbers, Peter A J; van Riel, Natal A W

    2018-06-01

    The Metabolic Syndrome (MetS) is a complex, multifactorial disorder that develops slowly over time presenting itself with large differences among MetS patients. We applied a systems biology approach to describe and predict the onset and progressive development of MetS, in a study that combined in vivo and in silico models. A new data-driven, physiological model (MINGLeD: Model INtegrating Glucose and Lipid Dynamics) was developed, describing glucose, lipid and cholesterol metabolism. Since classic kinetic models cannot describe slowly progressing disorders, a simulation method (ADAPT) was used to describe longitudinal dynamics and to predict metabolic concentrations and fluxes. This approach yielded a novel model that can describe long-term MetS development and progression. This model was integrated with longitudinal in vivo data that was obtained from male APOE*3-Leiden.CETP mice fed a high-fat, high-cholesterol diet for three months and that developed MetS as reflected by classical symptoms including obesity and glucose intolerance. Two distinct subgroups were identified: those who developed dyslipidemia, and those who did not. The combination of MINGLeD with ADAPT could correctly predict both phenotypes, without making any prior assumptions about changes in kinetic rates or metabolic regulation. Modeling and flux trajectory analysis revealed that differences in liver fluxes and dietary cholesterol absorption could explain this occurrence of the two different phenotypes. In individual mice with dyslipidemia dietary cholesterol absorption and hepatic turnover of metabolites, including lipid fluxes, were higher compared to those without dyslipidemia. Predicted differences were also observed in gene expression data, and consistent with the emergence of insulin resistance and hepatic steatosis, two well-known MetS co-morbidities. Whereas MINGLeD specifically models the metabolic derangements underlying MetS, the simulation method ADAPT is generic and can be applied to other diseases where dynamic modeling and longitudinal data are available.

  14. Novel ex vivo protocol using porcine vagina to assess drug permeation from mucoadhesive and colloidal pharmaceutical systems.

    PubMed

    Pereira, Maíra N; Reis, Thaiene A; Matos, Breno N; Cunha-Filho, Marcílio; Gratieri, Taís; Gelfuso, Guilherme M

    2017-10-01

    Local treatment of vaginal diseases presents advantages over systemic treatments and the interaction of the drug delivery systems with the biological tissue is a key factor for a successful vaginal topical therapy. Conventional protocols for permeation studies have high variability and fail in distinguishing drug penetration from mucoadhesive or colloidal drug delivery systems from conventional formulations, as tissue interaction is normally under estimated. The protocol presented in this paper is a simplified ex vivo vertical model, in which formulations are placed in hung porcine vaginas with the objective of mimicking a condition closer to the biological circumstance, specifically considering the possible leak from the vaginal canal in the vertical position. The results indicate the proposed method was capable of differentiating formulations performances and histological evaluation showed mucosa structures are preserved during this new assay. Therefore, the ex vivo method can be considered reliable for approaching the physiological situation in comparative studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. An ex vivo continuous passive motion model in a porcine knee for assessing primary stability of cell-free collagen gel plugs

    PubMed Central

    2010-01-01

    Background Primary stability of cartilage repair constructs is of the utmost importance in the clinical setting but few continuous passive motion (CPM) models are available. Our study aimed to establish a novel ex vivo CPM animal model and to evaluate the required motion cycles for testing the mechanical properties of a new cell-free collagen type I gel plug (CaReS®-1S). Methods A novel ex vivo CPM device was developed. Full-thickness cartilage defects (11 mm diameter by 6 mm deep) were created on the medial femoral condyle of porcine knee specimens. CaReS®-1S was implanted in 16 animals and each knee underwent continuous passive motion. After 0, 2000, 4000, 6000, and 8000 motions, standardized digital pictures of the grafts were taken, focusing on the worn surfaces. The percentage of worn surface on the total CaReS®-1S surface was evaluated with image processing software. Results Significant differences in the worn surface were recorded between 0 and 2000 motion cycles (p < 0.0001). After 2000 motion cycles, there was no significant difference. No total delamination of CaReS®-1S with an empty defect site was recorded. Conclusion The ex vivo CPM animal model is appropriate in investigating CaReS®-1S durability under continuous passive motion. 2000 motion cycles appear adequate to assess the primary stability of type I collagen gels used to repair focal chondral defects. PMID:21159196

  16. In vivo testing of Renilla luciferase substrate analogs in an orthotopic murine model of human glioblastoma.

    PubMed

    Otto-Duessel, Maya; Khankaldyyan, Vazgen; Gonzalez-Gomez, Ignacio; Jensen, Michael C; Laug, Walter E; Rosol, Michael

    2006-01-01

    In vivo bioluminescent imaging using cells expressing Renilla luciferase is becoming increasingly common. Hindrances to the more widespread use of Renilla luciferase are the high autoluminescence of its natural substrate, coelenterazine, in plasma, the relatively high absorbance by tissue of the light emitted by the enzyme-substrate reaction; rapid clearance of the substrate; and significant cost. These factors, save for the cost, which has its own limiting effect on use, can combine to reduce the sensitivity of in vivo assays utilizing this reporter system, and methods of increasing light output or decreasing autoluminescence could be of great benefit. A number of analogs of coelenterazine are being investigated may accomplish one or both of these goals. In this study that we report on the testing of two new substrate analogs, EnduRen and ViViren, manufactured by Promega Corporation, in an orthotopic murine model of human glioblastoma expressing Renilla luciferase. We have tested these analogs in this cell line both in vitro and in vivo, and find that the substrate viviren results in significantly greater light output than the natural substrate or the other analog EnduRen. This new substrate could be valuable for studies where greater sensitivity is important.

  17. Near-infrared fluorescence imaging platform for quantifying in vivo nanoparticle diffusion from drug loaded implants.

    PubMed

    Markovic, Stacey; Belz, Jodi; Kumar, Rajiv; Cormack, Robert A; Sridhar, Srinivas; Niedre, Mark

    2016-01-01

    Drug loaded implants are a new, versatile technology platform to deliver a localized payload of drugs for various disease models. One example is the implantable nanoplatform for chemo-radiation therapy where inert brachytherapy spacers are replaced by spacers doped with nanoparticles (NPs) loaded with chemotherapeutics and placed directly at the disease site for long-term localized drug delivery. However, it is difficult to directly validate and optimize the diffusion of these doped NPs in in vivo systems. To better study this drug release and diffusion, we developed a custom macroscopic fluorescence imaging system to visualize and quantify fluorescent NP diffusion from spacers in vivo. To validate the platform, we studied the release of free fluorophores, and 30 nm and 200 nm NPs conjugated with the same fluorophores as a model drug, in agar gel phantoms in vitro and in mice in vivo. Our data verified that the diffusion volume was NP size-dependent in all cases. Our near-infrared imaging system provides a method by which NP diffusion from implantable nanoplatform for chemo-radiation therapy spacers can be systematically optimized (eg, particle size or charge) thereby improving treatment efficacy of the platform.

  18. Multimodality animal rotation imaging system (Mars) for in vivo detection of intraperitoneal tumors.

    PubMed

    Pizzonia, John; Holmberg, Jennie; Orton, Sean; Alvero, Ayesha; Viteri, Oscar; McLaughlin, William; Feke, Gil; Mor, Gil

    2012-01-01

    PROBLEM Ovarian cancer stem cells (OCSCs) have been postulated as the potential source of recurrence and chemoresistance. Therefore identification of OvCSC and their complete removal is a pivotal stage for the treatment of ovarian cancer. The objective of the following study was to develop a new in vivo imaging model that allows for the detection and monitoring of OCSCs. METHOD OF STUDY  OCSCs were labeled with X-Sight 761 Nanospheres and injected intra-peritoneally (i.p.) and sub-cutaneously (s.c.) to Athymic nude mice. The Carestream In-Vivo Imaging System FX was used to obtain X-ray and, concurrently, near-infrared fluorescence images. Tumor images in the mouse were observed from different angles by automatic rotation of the mouse. RESULTS  X-Sight 761 Nanospheres labeled almost 100% of the cells. No difference on growth rate was observed between labeled and unlabeled cells. Tumors were observed and monitoring revealed strong signaling up to 21 days. CONCLUSION  We describe the use of near-infrared nanoparticle probes for in vivo imaging of metastatic ovarian cancer models. Visualization of multiple sites around the animals was enhanced with the use of the Carestream Multimodal Animal Rotation System. © 2011 John Wiley & Sons A/S.

  19. Robust Microplate-Based Methods for Culturing and in Vivo Phenotypic Screening of Chlamydomonas reinhardtii

    PubMed Central

    Haire, Timothy C.; Bell, Cody; Cutshaw, Kirstin; Swiger, Brendan; Winkelmann, Kurt; Palmer, Andrew G.

    2018-01-01

    Chlamydomonas reinhardtii (Cr), a unicellular alga, is routinely utilized to study photosynthetic biochemistry, ciliary motility, and cellular reproduction. Its minimal culture requirements, unicellular morphology, and ease of transformation have made it a popular model system. Despite its relatively slow doubling time, compared with many bacteria, it is an ideal eukaryotic system for microplate-based studies utilizing either, or both, absorbance as well as fluorescence assays. Such microplate assays are powerful tools for researchers in the areas of toxicology, pharmacology, chemical genetics, biotechnology, and more. However, while microplate-based assays are valuable tools for screening biological systems, these methodologies can significantly alter the conditions in which the organisms are cultured and their subsequent physiology or morphology. Herein we describe a novel method for the microplate culture and in vivo phenotypic analysis of growth, viability, and photosynthetic pigments of C. reinhardtii. We evaluated the utility of our assay by screening silver nanoparticles for their effects on growth and viability. These methods are amenable to a wide assortment of studies and present a significant advancement in the methodologies available for research involving this model organism. PMID:29623083

  20. Robust Microplate-Based Methods for Culturing and in Vivo Phenotypic Screening of Chlamydomonas reinhardtii.

    PubMed

    Haire, Timothy C; Bell, Cody; Cutshaw, Kirstin; Swiger, Brendan; Winkelmann, Kurt; Palmer, Andrew G

    2018-01-01

    Chlamydomonas reinhardtii (Cr), a unicellular alga, is routinely utilized to study photosynthetic biochemistry, ciliary motility, and cellular reproduction. Its minimal culture requirements, unicellular morphology, and ease of transformation have made it a popular model system. Despite its relatively slow doubling time, compared with many bacteria, it is an ideal eukaryotic system for microplate-based studies utilizing either, or both, absorbance as well as fluorescence assays. Such microplate assays are powerful tools for researchers in the areas of toxicology, pharmacology, chemical genetics, biotechnology, and more. However, while microplate-based assays are valuable tools for screening biological systems, these methodologies can significantly alter the conditions in which the organisms are cultured and their subsequent physiology or morphology. Herein we describe a novel method for the microplate culture and in vivo phenotypic analysis of growth, viability, and photosynthetic pigments of C. reinhardtii . We evaluated the utility of our assay by screening silver nanoparticles for their effects on growth and viability. These methods are amenable to a wide assortment of studies and present a significant advancement in the methodologies available for research involving this model organism.

  1. Carotid artery mechanical properties and stresses quantified using in vivo data from normotensive and hypertensive humans.

    PubMed

    Masson, Ingrid; Beaussier, Hélène; Boutouyrie, Pierre; Laurent, Stéphane; Humphrey, Jay D; Zidi, Mustapha

    2011-12-01

    The goal of this study was to model the in vivo non-linear mechanical behavior of human common carotid arteries (CCAs) and then to compare wall stresses and associated contributions of micro-constituents in normotensive (NT) and treated hypertensive (HT) subjects. We used an established theoretical model of 3D arterial mechanics that assumes a hyperelastic, anisotropic, active-passive, and residually stressed wall. In vivo data were obtained non-invasively from CCAs in 16 NT (21-64 years old) and 25 treated HT (44-69 years old) subjects. The associated quasi-static boundary value problem was solved semi-analytically over a cardiac cycle while accounting for surrounding perivascular tissue. Best-fit values of model parameters, including those describing contributions by intramural elastin, fibrillar collagen, and vascular smooth muscle, were estimated by a non-linear least-squares method. The model (1) captured temporal changes in intraluminal pressure, (2) estimated wall stress fields that appeared to reflect the presence or absence of age and disease, and (3) suggested changes in mechanical characteristics of wall micro-constituents despite medical treatment of hypertension. For example, age was positively correlated with residual stresses and altered fibrillar collagen in NT subjects, which indirectly validated the modeling, and HT subjects had higher levels of stresses, increased smooth muscle tone, and a stiffer elastin-dominated matrix despite treatment. These results are consistent with prior reports on effects of age and hypertension, but provide increased insight into evolving contributions of cell and matrix mechanics to arterial behavior in vivo.

  2. A Novel Perforator Flap Training Model Using a Chicken Leg

    PubMed Central

    Cifuentes, Ignacio J.; Yañez, Ricardo A.; Salisbury, Maria C.; Rodriguez, José R.; Varas, Julian E.; Dagnino, Bruno L.

    2016-01-01

    Introduction  Living animal models are frequently used for perforator flap dissection training, but no ex vivo models have been described. The aim of this study is to present a novel nonliving model for perforator flap training based on a constant perforator in the chicken leg. Methods  A total of 15 chicken legs were used in this study. Anatomical dissection of the perforator was performed after its identification using ink injection, and in four of these specimens a perforator-based flap was raised. Results  The anatomical dissection revealed a constant intramuscular perforator with a median length of 5.7 cm. Median proximal and distal vessel diameters were 0.93 and 0.4 mm, respectively. The median dissection time was 77.5 minutes. Conclusion  This study introduces a novel, affordable, and reproducible model for the intramuscular dissection of a perforator-based flap using an ex vivo animal model. Its consistent perforator and appropriate-sized vessels make it useful for training. PMID:27616823

  3. In vivo quantitative bioluminescence tomography using heterogeneous and homogeneous mouse models.

    PubMed

    Liu, Junting; Wang, Yabin; Qu, Xiaochao; Li, Xiangsi; Ma, Xiaopeng; Han, Runqiang; Hu, Zhenhua; Chen, Xueli; Sun, Dongdong; Zhang, Rongqing; Chen, Duofang; Chen, Dan; Chen, Xiaoyuan; Liang, Jimin; Cao, Feng; Tian, Jie

    2010-06-07

    Bioluminescence tomography (BLT) is a new optical molecular imaging modality, which can monitor both physiological and pathological processes by using bioluminescent light-emitting probes in small living animal. Especially, this technology possesses great potential in drug development, early detection, and therapy monitoring in preclinical settings. In the present study, we developed a dual modality BLT prototype system with Micro-computed tomography (MicroCT) registration approach, and improved the quantitative reconstruction algorithm based on adaptive hp finite element method (hp-FEM). Detailed comparisons of source reconstruction between the heterogeneous and homogeneous mouse models were performed. The models include mice with implanted luminescence source and tumor-bearing mice with firefly luciferase report gene. Our data suggest that the reconstruction based on heterogeneous mouse model is more accurate in localization and quantification than the homogeneous mouse model with appropriate optical parameters and that BLT allows super-early tumor detection in vivo based on tomographic reconstruction of heterogeneous mouse model signal.

  4. A fast referenceless PRFS-based MR thermometry by phase finite difference

    NASA Astrophysics Data System (ADS)

    Zou, Chao; Shen, Huan; He, Mengyue; Tie, Changjun; Chung, Yiu-Cho; Liu, Xin

    2013-08-01

    Proton resonance frequency shift-based MR thermometry is a promising temperature monitoring approach for thermotherapy but its accuracy is vulnerable to inter-scan motion. Model-based referenceless thermometry has been proposed to address this problem but phase unwrapping is usually needed before the model fitting process. In this paper, a referenceless MR thermometry method using phase finite difference that avoids the time consuming phase unwrapping procedure is proposed. Unlike the previously proposed phase gradient technique, the use of finite difference in the new method reduces the fitting error resulting from the ringing artifacts associated with phase discontinuity in the calculation of the phase gradient image. The new method takes into account the values at the perimeter of the region of interest because of their direct relevance to the extrapolated baseline phase of the region of interest (where temperature increase takes place). In simulation study, in vivo and ex vivo experiments, the new method has a root-mean-square temperature error of 0.35 °C, 1.02 °C and 1.73 °C compared to 0.83 °C, 2.81 °C, and 3.76 °C from the phase gradient method, respectively. The method also demonstrated a slightly higher, albeit small, temperature accuracy than the original referenceless MR thermometry method. The proposed method is computationally efficient (∼0.1 s per image), making it very suitable for the real time temperature monitoring.

  5. Solid lipid nanoparticles as carrier for sunscreens: in vitro release and in vivo skin penetration.

    PubMed

    Wissing, S A; Müller, R H

    2002-06-17

    The aim of this study was the comparison of two different formulations (solid lipid nanoparticles (SLN) and conventional o/w emulsion) as carrier systems for the molecular sunscreen oxybenzone. The influence of the carrier on the rate of release was studied in vitro with a membrane-free model. The release rate could be decreased by up to 50% with the SLN formulation. Further in vitro measurements with static Franz diffusion cells were performed. In vivo, penetration of oxybenzone into stratum corneum on the forearm was investigated by the tape stripping method. It was shown that the rate of release is strongly dependent upon the formulation and could be decreased by 30-60% in SLN formulations. In all test models, oxybenzone was released and penetrated into human skin more quickly and to a greater extent from the emulsions. The rate of release also depends upon the total concentration of oxybenzone in the formulation. In vitro-in vivo correlations could be made qualitatively.

  6. Medial surface dynamics of an in vivo canine vocal fold during phonation

    NASA Astrophysics Data System (ADS)

    Döllinger, Michael; Berry, David A.; Berke, Gerald S.

    2005-05-01

    Quantitative measurement of the medial surface dynamics of the vocal folds is important for understanding how sound is generated within the larynx. Building upon previous excised hemilarynx studies, the present study extended the hemilarynx methodology to the in vivo canine larynx. Through use of an in vivo model, the medial surface dynamics of the vocal fold were examined as a function of active thyroarytenoid muscle contraction. Data were collected using high-speed digital imaging at a sampling frequency of 2000 Hz, and a spatial resolution of 1024×1024 pixels. Chest-like and fry-like vibrations were observed, but could not be distinguished based on the input stimulation current to the recurrent laryngeal nerve. The subglottal pressure did distinguish the registers, as did an estimate of the thyroarytenoid muscle activity. Upon quantification of the three-dimensional motion, the method of Empirical Eigenfunctions was used to extract the underlying modes of vibration, and to investigate mechanisms of sustained oscillation. Results were compared with previous findings from excised larynx experiments and theoretical models. .

  7. Monitoring circulating prostate tumor cells after tumor resection by in vivo flow cytometry

    NASA Astrophysics Data System (ADS)

    Ding, Nan; Zhu, Xi; Xie, Chengying; Wei, Dan; Yang, Zhangru; Suo, Yuanzhen; Wei, Xunbin

    2018-02-01

    Prostate cancer has already become the biggest threat among all cancer types for male people and many people died because of its bone metastases. Circulating tumor cells (CTCs) can be used as early metastasis marker so that the detection of CTCs in blood is meaningful for early diagnosis and treatment. However, the relationship between these therapies and metastasis has not been fully clarified yet. Hence, we built PC3 subcutaneous tumor model and developed in vivo flow cytometer (IVFC) platform to record the dynamics of CTC before and after tumor resection. We found out that tumor resection can reduce CTC quantities instantaneously while having a good control of metastasis. CTC re-occurred 7 days after surgery, which might be correlated with early disseminated and deposited tumors. In conclusion, in vivo flow cytometry (IVFC) is capable of detecting CTC dynamics in prostate subcutaneous tumor model and this method could facilitate further research about relationship between other cancer therapies and circulating tumor cells.

  8. Characterization of an Isolated Kidney's Vasculature for Use in Bio-Thermal Modeling

    NASA Astrophysics Data System (ADS)

    Payne, Allison H.; Parker, Dennis L.; Moellmer, Jeff; Roemer, Robert B.; Clifford, Sarah

    2007-05-01

    Accurate bio-thermal modeling requires site-specific modeling of discrete vascular anatomy. Presented herewith are several steps that have been developed to describe the vessel network of isolated canine and bovine kidneys. These perfused, isolated kidneys provide an environment to repeatedly test and improve acquisition methods to visualize the vascular anatomy, as well as providing a method to experimentally validate discrete vasculature thermal models. The organs are preserved using a previously developed methodology that keeps the vasculature intact, allowing for the organ to be perfused. It also allows for the repeated fixation and re-hydration of the same organ, permitting the comparison of various methods and models. The organ extraction, alcohol preservation, and perfusion of the organ are described. The vessel locations were obtained through a high-resolution time-of-flight (TOF) magnetic resonance angiography (MRA) technique. Sequential improvements of both the experimental setup used for this acquisition, as well as MR sequence development are presented. The improvements in MR acquisition and experimental setup improved the number of vessels seen in both the raw data and segmented images by 50%. An automatic vessel centerline extraction algorithm describes both vessel location and genealogy. Centerline descriptions also allows for vessel diameter and flow rate determination, providing valuable input parameters for the discrete vascular thermal model. Characterized vessels networks of both canine and bovine kidneys are presented. While these tools have been developed in an ex vivo environment, all steps can be applied to in vivo applications.

  9. Deriving Signatures of In Vivo Toxicity Using Both Efficacy and Potency Information from In Vitro Assays: Evaluating Model Performance as a Function of Increasing Variability in Experimental Data

    EPA Science Inventory

    The US EPA ToxCast program aims to develop methods for mechanistically-based chemical prioritization using a suite of high throughput, in vitro assays that probe relevant biological pathways, and coupling them with statistical and machine learning methods that produce predictive ...

  10. A simple method to assess in vivo proliferation in lung vasculature with EdU: the case of MMC-induced PVOD in rat.

    PubMed

    Fabrice, Antigny; Benoît, Ranchoux; Valérie, Nadeau; Lau, Edmund; Sébastien, Bonnet; Frédéric, Perros

    2015-01-01

    5-Ethynyl-2'-deoxyuridine (EdU) incorporation is becoming the gold standard method for in vitro and in vivo visualization of proliferating cells. The small size of the fluorescent azides used for detection results in a high degree of specimen penetration. It can be used to easily detect DNA replication in large tissue samples or organ explants with low proliferation and turnover of cells formerly believed to be in a "terminal" state of differentiation. Here we describe a protocol for the localization and identification of proliferating cells in quiescent or injured pulmonary vasculature, in a model of pulmonary veno-occlusive disease (PVOD). PVOD is an uncommon form of pulmonary hypertension characterized by progressive obstruction of small pulmonary veins. We previously reported that mitomycin-C (MMC) therapy is associated with PVOD in human. We demonstrated that MMC can induce PVOD in rats, which currently represents the sole animal model that recapitulates human PVOD lesions. Using the EdU assay, we demonstrated that MMC-exposed lungs displayed areas of exuberant microvascular endothelial cell proliferation which mimics pulmonary capillary hemangiomatosis, one of the pathologic hallmarks of human PVOD. In vivo pulmonary cell proliferation measurement represents an interesting methodology to investigate the potential efficacy of therapies aimed at normalizing pathologic angioproliferation.

  11. In vivo Raman spectroscopy for oral cancers diagnosis

    NASA Astrophysics Data System (ADS)

    Singh, S. P.; Deshmukh, Atul; Chaturvedi, Pankaj; Krishna, C. Murali

    2012-01-01

    Oral squamous cell carcinoma is sixth among the major malignancies worldwide. Tobacco habits are known as major causative factor in tumor carcinogenesis in oral cancer. Optical spectroscopy methods, including Raman, are being actively pursued as alternative/adjunct for cancer diagnosis. Earlier studies have demonstrated the feasibility of classifying normal, premalignant and malignant oral ex-vivo tissues. In the present study we have recorded in vivo spectra from contralateral normal and diseased sites of 50 subjects with pathologically confirmed lesions of buccal mucosa using fiber-optic-probe-coupled HE-785 Raman spectrometer. Spectra were recorded on similar points as per teeth positions with an average acquisition time of 8 seconds. A total of 215 and 225 spectra from normal and tumor sites, respectively, were recorded. Finger print region (1200-1800 cm-1) was utilized for classification using LDA. Standard-model was developed using 125 normal and 139 tumor spectra from 27 subjects. Two separate clusters with an efficiency of ~95% were obtained. Cross-validation with leave-one-out yielded ~90% efficiency. Remaining 90 normal and 86 tumor spectra were used as test data and predication efficiency of model was evaluated. Findings of the study indicate that Raman spectroscopic methods in combination with appropriate multivariate tool can be used for objective, noninvasive and rapid diagnosis.

  12. Imaging Subcellular Structures in the Living Zebrafish Embryo.

    PubMed

    Engerer, Peter; Plucinska, Gabriela; Thong, Rachel; Trovò, Laura; Paquet, Dominik; Godinho, Leanne

    2016-04-02

    In vivo imaging provides unprecedented access to the dynamic behavior of cellular and subcellular structures in their natural context. Performing such imaging experiments in higher vertebrates such as mammals generally requires surgical access to the system under study. The optical accessibility of embryonic and larval zebrafish allows such invasive procedures to be circumvented and permits imaging in the intact organism. Indeed the zebrafish is now a well-established model to visualize dynamic cellular behaviors using in vivo microscopy in a wide range of developmental contexts from proliferation to migration and differentiation. A more recent development is the increasing use of zebrafish to study subcellular events including mitochondrial trafficking and centrosome dynamics. The relative ease with which these subcellular structures can be genetically labeled by fluorescent proteins and the use of light microscopy techniques to image them is transforming the zebrafish into an in vivo model of cell biology. Here we describe methods to generate genetic constructs that fluorescently label organelles, highlighting mitochondria and centrosomes as specific examples. We use the bipartite Gal4-UAS system in multiple configurations to restrict expression to specific cell-types and provide protocols to generate transiently expressing and stable transgenic fish. Finally, we provide guidelines for choosing light microscopy methods that are most suitable for imaging subcellular dynamics.

  13. Inside the beating heart: an in vivo feasibility study on fusing pre- and intra-operative imaging for minimally invasive therapy.

    PubMed

    Linte, Cristian A; Moore, John; Wedlake, Chris; Bainbridge, Daniel; Guiraudon, Gérard M; Jones, Douglas L; Peters, Terry M

    2009-03-01

    An interventional system for minimally invasive cardiac surgery was developed for therapy delivery inside the beating heart, in absence of direct vision. A system was developed to provide a virtual reality (VR) environment that integrates pre-operative imaging, real-time intra-operative guidance using 2D trans-esophageal ultrasound, and models of the surgical tools tracked using a magnetic tracking system. Detailed 3D dynamic cardiac models were synthesized from high-resolution pre-operative MR data and registered within the intra-operative imaging environment. The feature-based registration technique was employed to fuse pre- and intra-operative data during in vivo intracardiac procedures on porcine subjects. This method was found to be suitable for in vivo applications as it relies on easily identifiable landmarks, and hence, it ensures satisfactory alignment of pre- and intra-operative anatomy in the region of interest (4.8 mm RMS alignment accuracy) within the VR environment. Our initial experience in translating this work to guide intracardiac interventions, such as mitral valve implantation and atrial septal defect repair demonstrated feasibility of the methods. Surgical guidance in the absence of direct vision and with no exposure to ionizing radiation was achieved, so our virtual environment constitutes a feasible candidate for performing various off-pump intracardiac interventions.

  14. Electron Beam Sterilization Does Not Have a Detrimental Effect on the Ability of Extracellular Matrix Scaffolds to Support In Vivo Ligament Healing

    PubMed Central

    Proffen, Benedikt L.; Perrone, Gabriel S.; Fleming, Braden C.; Sieker, Jakob T.; Kramer, Joshua; Hawes, Michael L.; Badger, Gary J.; Murray, Martha M.

    2015-01-01

    Purpose Extra-cellular matrix (ECM) scaffolds have been used to enhance anterior cruciate ligament (ACL) repair in large animal models. To translate this technology to clinical care, identifying a method, which effectively sterilizes the material without significantly impairing in vivo function, is desirable. Methods 16 Yorkshire pigs underwent ACL transection and were randomly assigned to bridge-enhanced ACL repair – primary suture repair of the ACL with addition of autologous blood soaked ECM scaffold - with either 1) an aseptically processed ECM scaffold, or 2) an electron beam irradiated ECM scaffold. Primary outcome measures included sterility of the scaffold and biomechanical properties of the scaffold itself and the repaired ligament at eight weeks after surgery. Results Scaffolds treated with 15kGy electron beam irradiation had no bacterial or fungal growth noted, while aseptically processed scaffolds had bacterial growth in all tested samples. The mean biomechanical properties of the scaffold and healing ligament were lower in the electron beam group; however, differences were not statistically significant. Conclusions Electron beam irradiation was able to effectively sterilize the scaffolds. In addition, this technique had only a minimal impact on the in vivo function of the scaffolds when used for ligament healing in the porcine model. PMID:25676876

  15. In-plane ultrasonic needle tracking using a fiber-optic hydrophone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xia, Wenfeng, E-mail: wenfeng.xia@ucl.ac.uk; Desjardins, Adrien E.; Mari, Jean Martial

    Purpose: Accurate and efficient guidance of needles to procedural targets is critically important during percutaneous interventional procedures. Ultrasound imaging is widely used for real-time image guidance in a variety of clinical contexts, but with this modality, uncertainties about the location of the needle tip within the image plane lead to significant complications. Whilst several methods have been proposed to improve the visibility of the needle, achieving accuracy and compatibility with current clinical practice is an ongoing challenge. In this paper, the authors present a method for directly visualizing the needle tip using an integrated fiber-optic ultrasound receiver in conjunction withmore » the imaging probe used to acquire B-mode ultrasound images. Methods: Needle visualization and ultrasound imaging were performed with a clinical ultrasound imaging system. A miniature fiber-optic ultrasound hydrophone was integrated into a 20 gauge injection needle tip to receive transmissions from individual transducer elements of the ultrasound imaging probe. The received signals were reconstructed to create an image of the needle tip. Ultrasound B-mode imaging was interleaved with needle tip imaging. A first set of measurements was acquired in water and tissue ex vivo with a wide range of insertion angles (15°–68°) to study the accuracy and sensitivity of the tracking method. A second set was acquired in an in vivo swine model, with needle insertions to the brachial plexus. A third set was acquired in an in vivo ovine model for fetal interventions, with insertions to different locations within the uterine cavity. Two linear ultrasound imaging probes were used: a 14–5 MHz probe for the first and second sets, and a 9–4 MHz probe for the third. Results: During insertions in tissue ex vivo and in vivo, the imaged needle tip had submillimeter axial and lateral dimensions. The signal-to-noise (SNR) of the needle tip was found to depend on the insertion angle. With the needle tip in water, the SNR of the needle tip varied with insertion angle, attaining values of 284 at 27° and 501 at 68°. In swine tissue ex vivo, the SNR decreased from 80 at 15° to 16 at 61°. In swine tissue in vivo, the SNR varied with depth, from 200 at 17.5 mm to 48 at 26 mm, with a constant insertion angle of 40°. In ovine tissue in vivo, within the uterine cavity, the SNR varied from 46.4 at 25 mm depth to 18.4 at 32 mm depth, with insertion angles in the range of 26°–65°. Conclusions: A fiber-optic ultrasound receiver integrated into the needle cannula in combination with single-element transmissions from the imaging probe allows for direct visualization of the needle tip within the ultrasound imaging plane. Visualization of the needle tip was achieved at depths and insertion angles that are encountered during nerve blocks and fetal interventions. The method presented in this paper has strong potential to improve the safety and efficiency of ultrasound-guided needle insertions.« less

  16. Spinal loads as influenced by external loads: a combined in vivo and in silico investigation.

    PubMed

    Zander, Thomas; Dreischarf, Marcel; Schmidt, Hendrik; Bergmann, Georg; Rohlmann, Antonius

    2015-02-26

    Knowledge of in vivo spinal loads and muscle forces remains limited but is necessary for spinal biomechanical research. To assess the in vivo spinal loads, measurements with telemeterised vertebral body replacements were performed in four patients. The following postures were investigated: (a) standing with arms hanging down on sides, (b) holding dumbbells to subject the patient to a vertical load, and (c) the forward elevation of arms for creating an additional flexion moment. The same postures were simulated by an inverse static model for validation purposes, to predict muscle forces, and to assess the spinal loads in subjects without implants. Holding dumbbells on sides increased implant forces by the magnitude of the weight of the dumbbells. In contrast, elevating the arms yielded considerable implant forces with a high correlation between the external flexion moment and the implant force. Predictions agreed well with experimental findings, especially for forward elevation of arms. Flexion moments were mainly compensated by erector spinae muscles. The implant altered the kinematics and, thus, the spinal loads. Elevation of both arms in vivo increased spinal axial forces by approximately 100N; each additional kg of dumbbell weight held in the hands increased the spinal axial forces by 60N. Model predictions suggest that in the intact situation, the force increase is one-third greater for these loads. In vivo measurements are essential for the validation of analytical models, and the combination of both methods can reveal unquantifiable data such as the spinal loads in the intact non-instrumented situation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. MODELING A MIXTURE: PBPK/PD APPROACHES FOR PREDICTING CHEMICAL INTERACTIONS.

    EPA Science Inventory

    Since environmental chemical exposures generally involve multiple chemicals, there are both regulatory and scientific drivers to develop methods to predict outcomes of these exposures. Even using efficient statistical and experimental designs, it is not possible to test in vivo a...

  18. In vivo study of endometriosis in mice by photoacoustic microscopy.

    PubMed

    Ding, Yichen; Zhang, Mingzhu; Lang, Jinghe; Leng, Jinhua; Ren, Qiushi; Yang, Jie; Li, Changhui

    2015-01-01

    Endometriosis (EM) impacts the healthcare and the quality of life for women of reproductive age. However, there is no reliable noninvasive diagnosis method for either animal study or clinical use. In this work, a novel imaging method, photoacoustic microscopy (PAM) was employed to study the EM on the mouse model. Our results demonstrated the PAM noninvasively provided the high contrast and 3D imaging of subcutaneously implanted EM tissue in the nude mouse in vivo. The statistical study also indicated PAM had high sensitivity and specificity in the diagnosis of EM in this animal study. In addition, we also discussed the potential clinical application for PAM in the diagnosis of EM. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Characterization of lipid-rich plaques using spectroscopic optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Nam, Hyeong Soo; Song, Joon Woo; Jang, Sun-Joo; Lee, Jae Joong; Oh, Wang-Yuhl; Kim, Jin Won; Yoo, Hongki

    2016-07-01

    Intravascular optical coherence tomography (IV-OCT) is a high-resolution imaging method used to visualize the internal structures of walls of coronary arteries in vivo. However, accurate characterization of atherosclerotic plaques with gray-scale IV-OCT images is often limited by various intrinsic artifacts. In this study, we present an algorithm for characterizing lipid-rich plaques with a spectroscopic OCT technique based on a Gaussian center of mass (GCOM) metric. The GCOM metric, which reflects the absorbance properties of lipids, was validated using a lipid phantom. In addition, the proposed characterization method was successfully demonstrated in vivo using an atherosclerotic rabbit model and was found to have a sensitivity and specificity of 94.3% and 76.7% for lipid classification, respectively.

  20. Modeling the oxygen microheterogeneity of tumors for photodynamic therapy dosimetry

    NASA Astrophysics Data System (ADS)

    Pogue, Brian W.; Paulsen, Keith D.; O'Hara, Julia A.; Hoopes, P. Jack; Swartz, Harold

    2000-03-01

    Photodynamic theory of tumors uses optical excitation of a sensitizing drug within tissue to produce large deposits of singlet oxygen, which are thought to ultimately cause the tumor destruction. Predicting dose deposition of singlet oxygen in vivo is challenging because measurement of this species in vivo is not easily achieved. But it is possible to follow the concentration of oxygen in vivo, and so measuring the oxygen concentration transients during PDT may provide a viable method of estimating the delivered dose of singlet oxygen. However modeling the microscopic heterogeneity of the oxygen distribution within a tumor is non-trivial, and predicting the microscopic dose deposition requires further study, but this study present the framework and initial calibration needed or modeling oxygen transport in complex geometries. Computational modeling with finite elements provides a versatile structure within which oxygen diffusion and consumption can be modeled within realistic tissue geometries. This study develops the basic tools required to simulate a tumor region, and examines the role of (i) oxygen supply and consumption rates, (ii) inter- capillary spacing, (iii) photosensitizer distribution, and (iv) differences between simulated tumors and those derived directly from histology. The result of these calculations indicate that realistic tumor tissue capillary networks can be simulated using the finite element method, without excessive computational burden for 2D regions near 1 mm2, and 3D regions near 0.1mm3. These simulations can provide fundamental information about tissue and ways to implement appropriate oxygen measurements. These calculations suggest that photodynamic therapy produces the majority of singlet oxygen in and near the blood vessels, because these are the sites of highest oxygen tension. These calculations support the concept that tumor vascular regions are the major targets for PDT dose deposition.

  1. Localized viscoelasticity measurements with untethered intravitreal microrobots.

    PubMed

    Pokki, Juho; Ergeneman, Olgaç; Bergeles, Christos; Torun, Hamdi; Nelson, Bradley J

    2012-01-01

    Microrobots are a promising tool for medical interventions and micromanipulation. In this paper, we explore the concept of using microrobots for microrheology. Untethered magnetically actuated microrobots were used to characterize one of the most complex biofluids, the vitreous humor. In this work we began by experimentally characterizing the viscoelastic properties of an artificial vitreous humor. For comparison, its properties were also measured using special microcantilevers in an atomic force microscope (AFM) setup. Subsequently, an untethered device was used to study the vitreous humor of a porcine eye, which is a valid ex-vivo model of a human eye. Its viscoelasticity model was extracted, which was in agreement with the model of the artificial vitreous. The existing characterization methodology requires eye and vitreous humor dissection for the microrheology measurements. We envision that the method proposed here can be used in in vivo.

  2. Conductive polymer nanotube patch for fast and controlled ex vivo transdermal drug delivery.

    PubMed

    Nguyen, Thao M; Lee, Sebin; Lee, Sang Bok

    2014-10-01

    To uptake and release hydrophilic model drugs and insulin in a novel conductive polymer (CP) nanotube transdermal patch. The externally controlled transdermal delivery of model drugs and insulin were tested ex vivo and results were compared with CP films. The unique intrinsic properties of CPs provide electrostatic interaction between the model drugs and polymer backbone. When a pulsed potential was applied, the drug delivery release profile mimics that of injection delivery. With a constant potential applied, the release rate constants of the patch system were up to three-times faster than the control (0 V) and released approximately 80% more drug molecules over 24 h. The CP nanotube transdermal patch represents a new and promising drug method, specifically for hydrophilic molecules, which have been a large obstacle for conventional transdermal drug delivery systems.

  3. Patient-derived Models of Human Breast Cancer: Protocols for In vitro and In vivo Applications in Tumor Biology and Translational Medicine

    PubMed Central

    DeRose, Yoko S.; Gligorich, Keith M.; Wang, Guoying; Georgelas, Ann; Bowman, Paulette; Courdy, Samir J.; Welm, Alana L.; Welm, Bryan E.

    2013-01-01

    Research models that replicate the diverse genetic and molecular landscape of breast cancer are critical for developing the next generation therapeutic entities that can target specific cancer subtypes. Patient-derived tumorgrafts, generated by transplanting primary human tumor samples into immune-compromised mice, are a valuable method to model the clinical diversity of breast cancer in mice, and are a potential resource in personalized medicine. Primary tumorgrafts also enable in vivo testing of therapeutics and make possible the use of patient cancer tissue for in vitro screens. Described in this unit are a variety of protocols including tissue collection, biospecimen tracking, tissue processing, transplantation, and 3-dimensional culturing of xenografted tissue, that enable use of bona fide uncultured human tissue in designing and validating cancer therapies. PMID:23456611

  4. Optimization of data analysis for the in vivo neutron activation analysis of aluminum in bone.

    PubMed

    Mohseni, H K; Matysiak, W; Chettle, D R; Byun, S H; Priest, N; Atanackovic, J; Prestwich, W V

    2016-10-01

    An existing system at McMaster University has been used for the in vivo measurement of aluminum in human bone. Precise and detailed analysis approaches are necessary to determine the aluminum concentration because of the low levels of aluminum found in the bone and the challenges associated with its detection. Phantoms resembling the composition of the human hand with varying concentrations of aluminum were made for testing the system prior to the application to human studies. A spectral decomposition model and a photopeak fitting model involving the inverse-variance weighted mean and a time-dependent analysis were explored to analyze the results and determine the model with the best performance and lowest minimum detection limit. The results showed that the spectral decomposition and the photopeak fitting model with the inverse-variance weighted mean both provided better results compared to the other methods tested. The spectral decomposition method resulted in a marginally lower detection limit (5μg Al/g Ca) compared to the inverse-variance weighted mean (5.2μg Al/g Ca), rendering both equally applicable to human measurements. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Hyperglycaemia attenuates in vivo reprogramming of pancreatic exocrine cells to beta cells in mice

    PubMed Central

    Cavelti-Weder, Claudia; Li, Weida; Zumsteg, Adrian; Stemann-Andersen, Marianne; Zhang, Yuemei; Yamada, Takatsugu; Wang, Max; Lu, Jiaqi; Jermendy, Agnes; Bee, Yong Mong; Bonner-Weir, Susan; Weir, Gordon C.; Zhou, Qiao

    2016-01-01

    Aims/hypothesis Reprogramming of pancreatic exocrine to insulin-producing cells by viral delivery of the genes encoding transcription factors neurogenin-3 (Ngn3), pancreas/duodenum homeobox protein 1 (Pdx1) and MafA is an efficient method for reversing diabetes in murine models. The variables that modulate reprogramming success are currently ill-defined. Methods Here, we assess the impact of glycaemia on in vivo reprogramming in a mouse model of streptozotocin-induced beta cell ablation, using subsequent islet transplantation or insulin pellet implantation for creation of groups with differing levels of glycaemia before viral delivery of transcription factors. Results We observed that hyperglycaemia significantly impaired reprogramming of exocrine to insulin-producing cells in their quantity, differentiation status and function. With hyperglycaemia, the reprogramming of acinar towards beta cells was less complete. Moreover, inflammatory tissue changes within the exocrine pancreas including macrophage accumulation were found, which may represent the tissue’s response to clear the pancreas from insufficiently reprogrammed cells. Conclusions/interpretation Our findings shed light on normoglycaemia as a prerequisite for optimal reprogramming success in a diabetes model, which might be important in other tissue engineering approaches and disease models, potentially facilitating their translational applications. PMID:26693711

  6. A study of the uptake and biodistribution of nano-titanium dioxide using in vitro and in vivo models of oral intake

    NASA Astrophysics Data System (ADS)

    MacNicoll, Alan; Kelly, Mick; Aksoy, Hatice; Kramer, Evelien; Bouwmeester, Hans; Chaudhry, Qasim

    2015-02-01

    Certain food additives may contain a sizeable fraction of particles in the nanoscale. However, little is known about the fate, behaviour and toxicological effects of orally-ingested nanoparticles. This study investigated the uptake and biodistribution of nano- and larger-sized titanium dioxide (TiO2) using an in vitro model of gut epithelium and in vivo in rat. The results of the in vivo study showed that oral administration of 5 mg/kg body weight of TiO2 nano- or larger particles did not lead to any significant translocation of TiO2 (measured as titanium) either to blood, urine or to various organs in rat at any of the time intervals studied over a 96 h post-administration period. Different methods used for dispersing particles did not affect the uptake, and orally administered TiO2 was found excreted in the faeces over a period of time. The in vitro study provided further evidence for the lack of translocation of TiO2 across the gut epithelium model. The overall evidence from both in vivo and in vitro studies did not support that oral ingestion of nano- or larger particles of TiO2 via food would result in any significant internal exposure of the consumer to the nanoparticles. The dietary TiO2 nanoparticles are likely to be excreted in the faeces.

  7. In vivo measurements of optical properties of human muscles with visible and near infrared reflectance spectroscopy

    NASA Astrophysics Data System (ADS)

    Wang, Chiao Yi; Yu, Ting Wen; Sung, Kung Bin

    2018-02-01

    Estimating optical properties of tissues is a crucial step to model photon migration in tissue, facilitate the design of the probe geometry, better interpret data measured from tissue and predict photon energy distributions in tissue for various diagnostic and therapeutic applications. Diffuse reflectance spectroscopy (DRS) using visible and near-infrared light is a well-known method for estimating optical properties of tissues. For estimating optical properties of muscles, most existing researches have used integrating spheres for ex-vivo measurements. However, due to inter-subject variability and sitespecific conditions, an in-vivo approach can provide more accurate estimations of muscle absorption and scattering coefficients, which is important for the tomographic reconstruction of changes in the absorption or fluorescence in tissue. In this study, we used DRS with wavelengths between 600 nm and 800 nm and a fiber bundle with source-to-detector separations in the range of 0.18-0.35 cm to quantify wavelength-dependent scattering and absorption coefficients of human muscles in vivo with an inverse Monte Carlo model. Reflectance spectra were measured on the neck and the upper arm of one volunteer. After calibrating spectra with tissue phantoms made of Intralipid and India ink, we estimated scattering and absorption coefficients of muscles. The results are compared to those measured ex vivo in the literature.

  8. New molecular settings to support in vivo anti-malarial assays.

    PubMed

    Bahamontes-Rosa, Noemí; Alejandre, Ane Rodriguez; Gomez, Vanesa; Viera, Sara; Gomez-Lorenzo, María G; Sanz-Alonso, Laura María; Mendoza-Losana, Alfonso

    2016-03-08

    Quantitative real-time PCR (qPCR) is now commonly used as a method to confirm diagnosis of malaria and to differentiate recrudescence from re-infection, especially in clinical trials and in reference laboratories where precise quantification is critical. Although anti-malarial drug discovery is based on in vivo murine efficacy models, use of molecular analysis has been limited. The aim of this study was to develop qPCR as a valid methodology to support pre-clinical anti-malarial models by using filter papers to maintain material for qPCR and to compare this with traditional methods. FTA technology (Whatman) is a rapid and safe method for extracting nucleic acids from blood. Peripheral blood samples from mice infected with Plasmodium berghei, P. yoelii, or P. falciparum were kept as frozen samples or as spots on FTA cards. The extracted genetic material from both types of samples was assessed for quantification by qPCR using sets of specific primers specifically designed for Plasmodium 18S rRNA, LDH, and CytB genes. The optimal conditions for nucleic acid extraction from FTA cards and qPCR amplification were set up, and were confirmed to be suitable for parasite quantification using DNA as template after storage at room temperature for as long as 26 months in the case of P. berghei samples and 52 months for P. falciparum and P. yoelii. The quality of DNA extracted from the FTA cards for gene sequencing and microsatellite amplification was also assessed. This is the first study to report the suitability of FTA cards and qPCR assay to quantify parasite load in samples from in vivo efficacy models to support the drug discovery process.

  9. Development of an in vitro Bioassay for Recombinant Human Erythropoietin (rHuEPO) Based on Proliferative Stimulation of an Erythroid Cell Line and Analysis of Sialic Acid Dependent Microheterogeneity: UT-7 Cell Bioassay.

    PubMed

    Metta, Manoj Kumar; Malkhed, Vasavi; Tantravahi, Srinivasan; Vuruputuri, Uma; Kunaparaju, Rajkumar

    2017-04-01

    Determination of biological activity and its comparison with clinical behavior is important in the quality assessment of therapeutic glycoproteins. In vivo studies are usually employed for evaluating bioactivity of these glycomolecules. However, alternative methods are required to simplify the bioassay and avoid ethical issues associated with in vivo studies. Negatively charged sialic acid residues are known to be critical for in vivo bioactivity of rHuEPO. To address this need, we employed the human acute myeloid leukemia cell line UT-7 for the determination of proliferative stimulation induced by rHuEPO. Relative potencies of various intact and sugar-trimmed rHuEPO preparations were estimated using the International Standard for Human r-DNA derived EPO (87/684) as a reference for bioactivity. The cellular response was measured with a multi-channel photometer using a colorimetric microassay, based on the metabolism of the Resazurin sodium by cell viability. For a resourceful probing of physiological features of rHuEPO with significance, we obtained partly or completely desialylated rHuEPO digested by the neuraminidase enzyme without degradation of carbohydrates. Two-fold higher specific activity was shown by asialoerythropoietin in in vitro analysis compared with the sialoerythropoietin. Further, computational studies were also carried out to construct the 3D model of the erythropoietin (EPO) protein structure using standard comparative modeling methods. The quality of the model was validated using Procheck and protein structure analysis (ProSA) server tools. N-glycan units were constructed; moreover, EPO protein was glycosylated at potential glycosylation amino acid residue sites. The method described should be suitable for potency assessments of pharmaceutical formulations of rHuEPO (European Pharmacopeia, 2016).

  10. In-vivo detection of bleeding simulated in a Peritoneal dialysis model using a hemiarray EIT configuration

    NASA Astrophysics Data System (ADS)

    Tucker, Aaron S.; Ross, Edward; Paugh-Miller, Jennifer; Sadleir, Rosalind J.

    2010-04-01

    A new method to image and quantify intra-abdominal hemorrhage (IAH) using electrical impedance tomography (EIT) was tested. We proposed an electrode hemi-array placed exclusively on the anterior abdomen to monitor a supine patient for IAH without complicating concurrent traumatic injuries. Peritoneal dialysis (PD) was used as a model for IAH to assess the in vivo performance of the hemi-array. Using the EPack 2 data acquisition system, EIT measurements were recorded before, during, and after the administration of dialysate. Simultaneously, the amount of dialysate was recorded, synchronous to the EIT measurements, to be used as a control. Tomographic images of impedance change were reconstructed using a weighted, sensitivity-based method and then post-processed to obtain a quantitative estimate of the total dialysate administered. Our preliminary study included two subjects, one male and one female, each participating for two sessions, spaced about six months apart. Data collected from these sessions indicate that with a realized in vivo SNR of about 35dB the EPack 2 can detect accumulations larger than about 100mL with a quantification uncertainty of about +/- 50mL. Using these data we have developed new algorithms that can automatically detect the onset of bleeding in less than two minutes. This method shows promise for automated detection of other pathologies, e.g. ascites, and is adaptable for use on other anatomy including the skull, and pelvis.

  11. Delivery of RNAi reagents in murine models of obesity and diabetes.

    PubMed

    Wilcox, Denise M; Yang, Ruojing; Morgan, Sherry J; Nguyen, Phong T; Voorbach, Martin J; Jung, Paul M; Haasch, Deanna L; Lin, Emily; Bush, Eugene N; Opgenorth, Terry J; Jacobson, Peer B; Collins, Christine A; Rondinone, Cristina M; Surowy, Terry; Landschulz, Katherine T

    2006-11-29

    RNA interference (RNAi) is an exciting new tool to effect acute in vivo knockdown of genes for pharmacological target validation. Testing the application of this technology to metabolic disease targets, three RNAi delivery methods were compared in two frequently utilized preclinical models of obesity and diabetes, the diet-induced obese (DIO) and B6.V-Lep/J (ob/ob) mouse. Intraperitoneal (i.p.) and high pressure hydrodynamic intravenous (i.v.) administration of naked siRNA, and low pressure i.v. administration of shRNA-expressing adenovirus were assessed for both safety and gene knockdown efficacy using constructs targeting cJun N-terminal kinase 1 (JNK1). Hydrodynamic delivery of siRNA lowered liver JNK1 protein levels 40% in DIO mice, but was accompanied by iatrogenic liver damage. The ob/ob model proved even more intolerant of this technique, with hydrodynamic delivery resulting in severe liver damage and death of most animals. While well-tolerated, i.p. injections of siRNA in DIO mice did not result in any knockdown or phenotypic changes in the mice. On the other hand, i.v. injected adenovirus expressing shRNA potently reduced expression of JNK1 in vivo by 95% without liver toxicity. In conclusion, i.p. and hydrodynamic injections of siRNA were ineffective and/or inappropriate for in vivo gene targeting in DIO and ob/ob mice, while adenovirus-mediated delivery of shRNA provided a relatively benign and effective method for exploring liver target silencing.

  12. Inhibition by yeast killer toxin-like antibodies of oral Streptococci adhesion to tooth surfaces in an ex vivo model.

    PubMed Central

    Conti, Stefania; Magliani, Walter; Arseni, Simona; Frazzi, Raffaele; Salati, Antonella; Ravanetti, Lara; Polonelli, Luciano

    2002-01-01

    BACKGROUND: Monoclonal (KTmAb) and recombinant (KTscFv) anti-idiotypic antibodies, representing the internal image of a yeast killer toxin, proved to be microbicidal in vitro against important eukaryotic and prokaryotic pathogens such as Candida albicans, Pneumocystis carinii, Mycobacterium tuberculosis, Staphylococcus aureus, S. haemolyticus, Enterococcus faecalis, E. faecium, and Streptococcus pneumoniae, including multidrug-resistant strains. KTmAb and KTscFv exerted a strong therapeutic effect in well-established animal models of candidiasis and pneumocystosis. Streptococcus mutans is the most important etiologic agent of dental caries that might result from the metabolic end products of dental plaque. Effective strategies to reduce the disease potential of dental plaque have considered the possibility of using antibiotics or antibodies against oral streptococci in general and S. mutans in particular. In this study, the activity of KTmAb and KTscFv against S. mutans and the inhibition and reduction by KTmAb of dental colonization by S. mutans and other oral streptococci in an ex vivo model of human teeth were investigated. MATERIALS AND METHODS: KTscFv and KTmAb were used in a conventional colony forming unit (CFU) assay against a serotype C strain of S. mutans, and other oral streptococci (S. intermedius, S. mitis, S. oralis, S. salivarius). An ex vivo model of human teeth submerged in saliva was used to establish KTmAb potential of inhibiting or reducing the adhesion to dental surfaces by S. mutans and other oral streptococci. RESULTS: KTmAb and KTscFv kill in vitro S. mutans and other oral streptococci. KTmAb inhibit colonization of dental surfaces by S. mutans and oral streptococci in the ex vivo model. CONCLUSIONS: Killer antibodies with antibiotic activity or their engineered derivatives may have a potential in the prevention of dental caries in vivo. PMID:12428062

  13. Comparison study on the feasibility of photoacoustic power spectrum analysis in osteoporosis detection

    NASA Astrophysics Data System (ADS)

    He, Weizhen; Zhu, Yunhao; Feng, Ting; Wang, Huaideng; Yuan, Jie; Xu, Guan; Wang, Xueding; Carson, Paul

    2017-03-01

    Osteoporosis is a progressive bone disease which is characterized by a decrease in the bone mass and deterioration in bone micro-architecture. In theory, photoacoustic (PA) imaging analysis has potential to obtain the characteristics of the bone effectively. Previous study demonstrated that photoacoustic spectral analysis (PASA) method with the qualified parameter slope could provide an objective assessment of bone microstructure and deterioration. In this study, we tried to compare PASA method with the traditional quantitative ultrasound (QUS) method in osteoporosis assessment. Numerical simulations of both PA and ultrasound (US) signal are performed on computerized tomographic (CT) images of trabecular bone with different bone mineral densities (BMDs). Ex vivo experiments were conducted on porcine femur bone model of different BMDs. We compared the quantified parameter slope and the broadband ultrasound attenuation (BUA) coefficient from the PASA and QUS among different bone models, respectively. Both the simulation and ex vivo experiment results show that bone with low BMD has a higher slope value and lower BUA value. Our result demonstrated that the PASA method has the same efficacy with QUS in bone assessment, considering PA is a non-ionizing, non-invasive technique, PASA method holds potential for clinical diagnosis in osteoporosis and other bone diseases.

  14. In vivo, label-free, and noninvasive detection of melanoma metastasis by photoacoustic flow cytometry

    NASA Astrophysics Data System (ADS)

    Liu, Rongrong; Wang, Cheng; Hu, Cheng; Wang, Xueding; Wei, Xunbin

    2014-02-01

    Melanoma, a malignant tumor of melanocytes, is the most serious type of skin cancer in the world. It accounts for about 80% of deaths of all skin cancer. For cancer detection, circulating tumor cells (CTCs) serve as a marker for metastasis development, cancer recurrence, and therapeutic efficacy. Melanoma tumor cells have high content of melanin, which has high light absorption and can serve as endogenous biomarker for CTC detection without labeling. Here, we have developed an in vivo photoacoustic flow cytometry (PAFC) to monitor the metastatic process of melanoma cancer by counting CTCs of melanoma tumor bearing mice in vivo. To test in vivo PAFC's capability of detecting melanoma cancer, we have constructed a melanoma tumor model by subcutaneous inoculation of highly metastatic murine melanoma cancer cells, B16F10. In order to effectively distinguish the targeting PA signals from background noise, we have used the algorithm of Wavelet denoising method to reduce the background noise. The in vivo flow cytometry (IVFC) has shown a great potential for detecting circulating tumor cells quantitatively in the blood stream. Compared with fluorescence-based in vivo flow cytometry (IVFC), PAFC technique can be used for in vivo, label-free, and noninvasive detection of circulating tumor cells (CTCs).

  15. Noninvasive and label-free detection of circulating melanoma cells by in vivo photoacoustic flow cytometry

    NASA Astrophysics Data System (ADS)

    Yang, Ping; Liu, Rongrong; Niu, Zhenyu; Suo, Yuanzhen; He, Hao; Wei, Xunbin

    2015-03-01

    Melanoma is a malignant tumor of melanocytes. Circulating melanoma cell has high light absorption due to melanin highly contained in melanoma cells. This property is employed for the detection of circulating melanoma cell by in vivo photoacoustic flow cytometry (PAFC). PAFC is based on photoacoustic effect. Compared to in vivo flow cytometry based on fluorescence, PAFC can employ high melanin content of melanoma cells as endogenous biomarkers to detect circulating melanoma cells in vivo. In our research, we developed in vitro experiments to prove the ability of PAFC system of detecting PA signals from melanoma cells. For in vivo experiments, we constructed a model of melanoma tumor bearing mice by inoculating highly metastatic murine melanoma cancer cells B16F10 with subcutaneous injection. PA signals were detected in the blood vessels of mouse ears in vivo. By counting circulating melanoma cells termly, we obtained the number variation of circulating melanoma cells as melanoma metastasized. Those results show that PAFC is a noninvasive and label-free method to detect melanoma metastases in blood or lymph circulation. Our PAFC system is an efficient tool to monitor melanoma metastases, cancer recurrence and therapeutic efficacy.

  16. Automated 3-D cell counting method for grading uveitis of rodent eye in vivo with optical coherence tomograph.

    PubMed

    Choi, Woo June; Pepple, Kathryn L; Wang, Ruikang K

    2018-05-24

    In preclinical vision research, cell grading in small animal models is essential for the quantitative evaluation of intraocular inflammation. Here, we present a new and practical optical coherence tomography (OCT) image analysis method for the automated detection and counting of aqueous cells in the anterior chamber (AC) of a rodent model of uveitis. Anterior segment OCT (AS-OCT) images are acquired with a 100kHz swept-source OCT (SS-OCT) system. The proposed method consists of two steps. In the first step, we first despeckle and binarize each OCT image. After removing AS structures in the binary image, we then apply area thresholding to isolate cell-like objects. Potential cell candidates are selected based on their best fit to roundness. The second step performs the cell counting within the whole AC, in which additional cell tracking analysis is conducted on the successive OCT images to eliminate redundancy in cell counting. Finally, 3-D cell grading using the proposed method is demonstrated in longitudinal OCT imaging of a mouse model of anterior uveitis in vivo. Rendering of anterior segment (orange) of mouse eye and automatically counted anterior chamber cells (green). Inset is a top view of the rendering, showing the cell distribution across the anterior chamber. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  17. In vivo magnetic resonance measures of dark cytotoxicity of photosensitizers in a Murine tumor model

    NASA Astrophysics Data System (ADS)

    Ramaprasad, Subbaraya; Ripp, Elzbieta; Pi, Jiaxiong; Joshi, Shantaram S.; Pandey, Suresh K.; Missert, Joseph; Pandey, Ravindra K.

    2005-04-01

    Photodynamic therapy (PDT) is a novel cancer treatment modality where the therapeutic action is controlled by light and the potency of the photosensitizer used. Development of new potent photosensitizers (PS) for clinical applications requires that the PDT effects are maximized while minimizing dark cytotoxicity. The dark toxicity of photosensitizers is generally confirmed using cell lines. Photososensitizers that appear promising from in vitro assays need further investigations under in vivo conditions. As in vivo MR methods have the potential to provide information on the tumor status, they can be very effective tools to study dark toxicity of tumors. The tumor produced on the mouse foot dorsum was tested on two newly synthesized photosensitizers along with Photofrin as a control. The MR studies consisted of serial 31P spectral measurements both before and after PS injection. The results show significant changes in the tumor metabolism with increased inorganic phosphate while using new photosensitizers. However these changes slowly approached control levels several hours later. The studies performed while using Photofrin did not show any significant changes indicating minimal or no dark cytotoxicity. Similar studies performed on normal tissue such as the muscle indicated that the energy metabolism was minimally compromised. Our studies demonstrate that the effects of dark cytotoxicity can be observed by 31P MR. The growth profiles of tumors treated with PS alone indicate that the metabolic changes are temporary and do not interfere with the tumor growth. The studies suggest that MR is a new method of monitoring the effect of PS administered toxicity in an in vivo model.

  18. Quantify patient-specific coronary material property and its impact on stress/strain calculations using in vivo IVUS data and 3D FSI models: a pilot study

    PubMed Central

    Guo, Xiaoya; Zhu, Jian; Maehara, Akiko; Monoly, David; Samady, Habib; Wang, Liang; Billiar, Kristen L.; Zheng, Jie; Yang, Chun; Mintz, Gary S.; Giddens, Don P.; Tang, Dalin

    2016-01-01

    Computational models have been used to calculate plaque stress and strain for plaque progression and rupture investigations. An intravascular ultrasound (IVUS)-based modeling approach is proposed to quantify in vivo vessel material properties for more accurate stress/strain calculations. In vivo Cine IVUS and VH-IVUS coronary plaque data were acquired from one patient with informed consent obtained. Cine IVUS data and 3D thin-slice models with axial stretch were used to determine patient-specific vessel material properties. Twenty full 3D fluid–structure interaction models with ex vivo and in vivo material properties and various axial and circumferential shrink combinations were constructed to investigate the material stiffness impact on stress/strain calculations. The approximate circumferential Young’s modulus over stretch ratio interval [1.0, 1.1] for an ex vivo human plaque sample and two slices (S6 and S18) from our IVUS data were 1631, 641, and 346 kPa, respectively. Average lumen stress/strain values from models using ex vivo, S6 and S18 materials with 5 % axial shrink and proper circumferential shrink were 72.76, 81.37, 101.84 kPa and 0.0668, 0.1046, and 0.1489, respectively. The average cap strain values from S18 material models were 150–180 % higher than those from the ex vivo material models. The corresponding percentages for the average cap stress values were 50–75 %. Dropping axial and circumferential shrink consideration led to stress and strain over-estimations. In vivo vessel material properties may be considerably softer than those from ex vivo data. Material stiffness variations may cause 50–75 % stress and 150–180 % strain variations. PMID:27561649

  19. Stereotactic intracranial implantation and in vivo bioluminescent imaging of tumor xenografts in a mouse model system of glioblastoma multiforme.

    PubMed

    Baumann, Brian C; Dorsey, Jay F; Benci, Joseph L; Joh, Daniel Y; Kao, Gary D

    2012-09-25

    Glioblastoma multiforme (GBM) is a high-grade primary brain cancer with a median survival of only 14.6 months in humans despite standard tri-modality treatment consisting of surgical resection, post-operative radiation therapy and temozolomide chemotherapy. New therapeutic approaches are clearly needed to improve patient survival and quality of life. The development of more effective treatment strategies would be aided by animal models of GBM that recapitulate human disease yet allow serial imaging to monitor tumor growth and treatment response. In this paper, we describe our technique for the precise stereotactic implantation of bio-imageable GBM cancer cells into the brains of nude mice resulting in tumor xenografts that recapitulate key clinical features of GBM. This method yields tumors that are reproducible and are located in precise anatomic locations while allowing in vivo bioluminescent imaging to serially monitor intracranial xenograft growth and response to treatments. This method is also well-tolerated by the animals with low perioperative morbidity and mortality.

  20. A new method for in vivo visualization of vessel remodeling using a near-infrared dye

    PubMed Central

    Billaud, Marie; Ross, Jeremy A; Greyson, Mark A; Bruce, Anthony C; Seaman, Scott A; Heberlein, Katherine R; Han, Jenny; Best, Angela K; Peirce, Shayn M; Isakson, Brant E

    2011-01-01

    Intro Vascular obstructive events can be partially compensated for by remodeling processes that increase vessel diameter and collateral tortuosity. However, methods for visualizing remodeling events in vivo and with temporal comparisons from the same animal remain elusive. Methods Using a novel infrared conjugated polyethylene glycol dye, we investigated the possibility of intravital vascular imaging of the mouse ear before and after ligation of the primary feeder artery. For comparison, we used two different mouse models known to have impaired vascular remodeling post ligation (i.e. aged and PAI-1−/− mice). The results obtained with the infrared dye were confirmed using immunofluorescence labeling of the ear microvasculature with confocal microscopy. Results After ligation, increases in vessel diameter (between 10% and 60%) and tortuosity (approximately 15%) were observed in C57Bl/6 mice using both the infrared dye and the immunofluorescence technique. However, aged C57Bl/6 and PAI-1−/− mice did not show vascular remodeling following ligation. Conclusion Vascular remodeling can be visualized and accurately quantified using a new infrared dye in vivo. This analysis technique could be generally employed for quantitative investigations of changes in vascular remodeling. PMID:21418375

  1. In vivo spatial frequency domain spectroscopy of two layer media

    NASA Astrophysics Data System (ADS)

    Yudovsky, Dmitry; Nguyen, John Quan M.; Durkin, Anthony J.

    2012-10-01

    Monitoring of tissue blood volume and local oxygen saturation can inform the assessment of tissue health, healing, and dysfunction. These quantities can be estimated from the contribution of oxyhemoglobin and deoxyhemoglobin to the absorption spectrum of the dermis. However, estimation of blood related absorption in skin can be confounded by the strong absorption of melanin in the epidermis and epidermal thickness and pigmentation varies with anatomic location, race, gender, and degree of disease progression. Therefore, a method is desired that decouples the effect of melanin absorption in the epidermis from blood absorption in the dermis for a large range of skin types and thicknesses. A previously developed inverse method based on a neural network forward model was applied to simulated spatial frequency domain reflectance of skin for multiple wavelengths in the near infrared. It is demonstrated that the optical thickness of the epidermis and absorption and reduced scattering coefficients of the dermis can be determined independently and with minimal coupling. Then, the same inverse method was applied to reflectance measurements from a tissue simulating phantom and in vivo human skin. Oxygen saturation and total hemoglobin concentrations were estimated from the volar forearms of weakly and strongly pigmented subjects using a standard homogeneous model and the present two layer model.

  2. Selective visualization of fluorescent sterols in Caenorhabditis elegans by bleach-rate-based image segmentation.

    PubMed

    Wüstner, Daniel; Landt Larsen, Ane; Faergeman, Nils J; Brewer, Jonathan R; Sage, Daniel

    2010-04-01

    The nematode Caenorhabditis elegans is a genetically tractable model organism to investigate sterol transport. In vivo imaging of the fluorescent sterol, dehydroergosterol (DHE), is challenged by C. elegans' high autofluorescence in the same spectral region as emission of DHE. We present a method to detect DHE selectively, based on its rapid bleaching kinetics compared to cellular autofluorescence. Worms were repeatedly imaged on an ultraviolet-sensitive wide field (UV-WF) microscope, and bleaching kinetics of DHE were fitted on a pixel-basis to mathematical models describing the intensity decay. Bleach-rate constants were determined for DHE in vivo and confirmed in model membranes. Using this method, we could detect enrichment of DHE in specific tissues like the nerve ring, the spermateca and oocytes. We confirm these results in C. elegans gut-granule-loss (glo) mutants with reduced autofluorescence and compare our method with three-photon excitation microscopy of sterol in selected tissues. Bleach-rate-based UV-WF imaging is a useful tool for genetic screening experiments on sterol transport, as exemplified by RNA interference against the rme-2 gene coding for the yolk receptor and for worm homologues of Niemann-Pick C disease proteins. Our approach is generally useful for identifying fluorescent probes in the presence of high cellular autofluorescence.

  3. Insights on in vitro models for safety and toxicity assessment of cosmetic ingredients.

    PubMed

    Almeida, Andreia; Sarmento, Bruno; Rodrigues, Francisca

    2017-03-15

    According to the current European legislation, the safety assessment of each individual cosmetic ingredient of any formulation is the basis for the safety evaluation of a cosmetic product. Also, animal testing in the European Union is prohibited for cosmetic ingredients and products since 2004 and 2009, respectively. Additionally, the commercialization of any cosmetic products containing ingredients tested on animal models was forbidden in 2009. In consequence of these boundaries, the European Centre for the Validation of Alternative Methods (ECVAM) proposes a list of validated cell-based in vitro models for predicting the safety and toxicity of cosmetic ingredients. These models have been demonstrated as valuable and effective tools to overcome the limitations of animal in vivo studies. Although the use of in vitro cell-based models for the evaluation of absorption and permeability of cosmetic ingredients is widespread, a detailed study on the properties of these platforms and the in vitro-in vivo correlation compared with human data are required. Moreover, additional efforts must be taken to develop in vitro models to predict carcinogenicity, repeat dose toxicity and reproductive toxicity, for which no alternative in vitro methods are currently available. This review paper summarizes and characterizes the most relevant in vitro models validated by ECVAM employed to predict the safety and toxicology of cosmetic ingredients. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Extended release dosage form of glipizide: development and validation of a level A in vitro-in vivo correlation.

    PubMed

    Ghosh, Animesh; Bhaumik, Uttam Kumar; Bose, Anirbandeep; Mandal, Uttam; Gowda, Veeran; Chatterjee, Bappaditya; Chakrabarty, Uday Sankar; Pal, Tapan Kumar

    2008-10-01

    Defining a quantitative and reliable relationship between in vitro drug release and in vivo absorption is highly desired for rational development, optimization, and evaluation of controlled-release dosage forms and manufacturing process. During the development of once daily extended-release (ER) tablet of glipizide, a predictive in vitro drug release method was designed and statistically evaluated using three formulations with varying release rates. In order to establish internally and externally validated level A in vitro-in vivo correlation (IVIVC), a total of three different ER formulations of glipizide were used to evaluate a linear IVIVC model based on the in vitro test method. For internal validation, a single-dose four-way cross over study (n=6) was performed using fast-, moderate-, and slow-releasing ER formulations and an immediate-release (IR) of glipizide as reference. In vitro release rate data were obtained for each formulation using the United States Pharmacopeia (USP) apparatus II, paddle stirrer at 50 and 100 rev. min(-1) in 0.1 M hydrochloric acid (HCl) and pH 6.8 phosphate buffer. The f(2) metric (similarity factor) was used to analyze the dissolution data. The formulations were compared using area under the plasma concentration-time curve, AUC(0-infinity), time to reach peak plasma concentration, T(max), and peak plasma concentration, C(max), while correlation was determined between in vitro release and in vivo absorption. A linear correlation model was developed using percent absorbed data versus percent dissolved from the three formulations. Predicted glipizide concentrations were obtained by convolution of the in vivo absorption rates. Prediction errors were estimated for C(max) and AUC(0-infinity) to determine the validity of the correlation. Apparatus II, pH 6.8 at 100 rev. min(-1) was found to be the most discriminating dissolution method. Linear regression analysis of the mean percentage of dose absorbed versus the mean percentage of in vitro release resulted in a significant correlation (r(2)>or=0.9) for the three formulations.

  5. In vivo tomographic imaging of lung colonization of tumour in mouse with simultaneous fluorescence and X-ray CT.

    PubMed

    Zhang, Bin; Gao, Fuping; Wang, Mengjiao; Cao, Xu; Liu, Fei; Wang, Xin; Luo, Jianwen; Wang, Guangzhi; Bai, Jing

    2014-01-01

    Non-invasive in vivo imaging of diffuse and wide-spread colonization within the lungs, rather than distinct solid primary tumors, is still a challenging work. In this work, a lung colonization mouse model bearing A549 human lung tumor was simultaneously scanned by a dual-modality fluorescence molecular tomography (FMT) and X-ray computed tomography (CT) system in vivo. A two steps method which incorporates CT structural information into the FMT reconstruction procedure is employed to provide concurrent anatomical and functional information. By using the target-specific fluorescence agent, the fluorescence tomographic results show elevated fluorescence intensity deep within the lungs which is colonized with diffuse and wide-spread tumors. The results were confirmed with ex vivo fluorescence reflectance imaging and histological examination of the lung tissues. With FMT reconstruction combined with the CT information, the dual-modality FMT/micro-CT system is expected to offer sensitive and noninvasive imaging of diffuse tumor colonization within the lungs in vivo. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Clinical Implementation of a Model-Based In Vivo Dose Verification System for Stereotactic Body Radiation Therapy-Volumetric Modulated Arc Therapy Treatments Using the Electronic Portal Imaging Device.

    PubMed

    McCowan, Peter M; Asuni, Ganiyu; Van Uytven, Eric; VanBeek, Timothy; McCurdy, Boyd M C; Loewen, Shaun K; Ahmed, Naseer; Bashir, Bashir; Butler, James B; Chowdhury, Amitava; Dubey, Arbind; Leylek, Ahmet; Nashed, Maged

    2017-04-01

    To report findings from an in vivo dosimetry program implemented for all stereotactic body radiation therapy patients over a 31-month period and discuss the value and challenges of utilizing in vivo electronic portal imaging device (EPID) dosimetry clinically. From December 2013 to July 2016, 117 stereotactic body radiation therapy-volumetric modulated arc therapy patients (100 lung, 15 spine, and 2 liver) underwent 602 EPID-based in vivo dose verification events. A developed model-based dose reconstruction algorithm calculates the 3-dimensional dose distribution to the patient by back-projecting the primary fluence measured by the EPID during treatment. The EPID frame-averaging was optimized in June 2015. For each treatment, a 3%/3-mm γ comparison between our EPID-derived dose and the Eclipse AcurosXB-predicted dose to the planning target volume (PTV) and the ≥20% isodose volume were performed. Alert levels were defined as γ pass rates <85% (lung and liver) and <80% (spine). Investigations were carried out for all fractions exceeding the alert level and were classified as follows: EPID-related, algorithmic, patient setup, anatomic change, or unknown/unidentified errors. The percentages of fractions exceeding the alert levels were 22.6% for lung before frame-average optimization and 8.0% for lung, 20.0% for spine, and 10.0% for liver after frame-average optimization. Overall, mean (± standard deviation) planning target volume γ pass rates were 90.7% ± 9.2%, 87.0% ± 9.3%, and 91.2% ± 3.4% for the lung, spine, and liver patients, respectively. Results from the clinical implementation of our model-based in vivo dose verification method using on-treatment EPID images is reported. The method is demonstrated to be valuable for routine clinical use for verifying delivered dose as well as for detecting errors. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Wear characteristics of UHMW polyethylene by twist method

    NASA Astrophysics Data System (ADS)

    Chișiu, G.; Popescu, A. M.; Tudor, A.; Petrescu, A. M.; Stoica, G. F.; Subhi, K. A.

    2018-01-01

    A wear test of the twist movement was performed as a new method to estimate the in vivo wear behavior of an acetabular cup material for total knee replacements. A series of UHMWPE samples was used to evaluate the dynamic coefficient of friction in twist movement in contact with steel. The experimental data were conducted to validate the related theoretical model developed in the present study.

  8. CRISPR mediated somatic cell genome engineering in the chicken.

    PubMed

    Véron, Nadège; Qu, Zhengdong; Kipen, Phoebe A S; Hirst, Claire E; Marcelle, Christophe

    2015-11-01

    Gene-targeted knockout technologies are invaluable tools for understanding the functions of genes in vivo. CRISPR/Cas9 system of RNA-guided genome editing is revolutionizing genetics research in a wide spectrum of organisms. Here, we combined CRISPR with in vivo electroporation in the chicken embryo to efficiently target the transcription factor PAX7 in tissues of the developing embryo. This approach generated mosaic genetic mutations within a wild-type cellular background. This series of proof-of-principle experiments indicate that in vivo CRISPR-mediated cell genome engineering is an effective method to achieve gene loss-of-function in the tissues of the chicken embryo and it completes the growing genetic toolbox to study the molecular mechanisms regulating development in this important animal model. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Fostering efficacy and toxicity evaluation of traditional Chinese medicine and natural products: Chick embryo as a high throughput model bridging in vitro and in vivo studies.

    PubMed

    Wu, Tong; Yu, Gui-Yuan; Xiao, Jia; Yan, Chang; Kurihara, Hiroshi; Li, Yi-Fang; So, Kwok-Fai; He, Rong-Rong

    2018-04-19

    Efficacy and safety assessments are essential thresholds for drug candidates from preclinical to clinical research. Conventional mammalian in vivo models cannot offer rapid pharmacological and toxicological screening, whereas cell-based or cell-free in vitro systems often lead to inaccurate results because of the lack of physiological environment. Within the avian species, gallus gallus is the first bird to have its genome sequencing. Meantime, chick embryo is an easily operating, relatively transparent and extensively accessible model, whose physiological and pathological alterations can be visualized by egg candler, staining and image technologies. These features facilitate chick embryo as a high-throughput screening platform bridging in vivo and in vitro gaps in the pharmaceutical research. Due to the complicated ingredients and multiple-targets natures of traditional Chinese medicine (TCM), testing the efficacy and safety of TCM by in vitro methods are laborious and inaccurate, while testing in mammalian models consume massive cost and time. As such, the productive living organism chick embryo serves as an ideal biological system for pharmacodynamics studies of TCM. Herein, we comprehensively update recent progresses on the specialty of chick embryo in evaluation of efficacy and toxicity of drugs, with special concerns of TCM. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Suitability of [18F]altanserin and PET to determine 5-HT2A receptor availability in the rat brain: in vivo and in vitro validation of invasive and non-invasive kinetic models.

    PubMed

    Kroll, Tina; Elmenhorst, David; Matusch, Andreas; Wedekind, Franziska; Weisshaupt, Angela; Beer, Simone; Bauer, Andreas

    2013-08-01

    While the selective 5-hydroxytryptamine type 2a receptor (5-HT2AR) radiotracer [18F]altanserin is well established in humans, the present study evaluated its suitability for quantifying cerebral 5-HT2ARs with positron emission tomography (PET) in albino rats. Ten Sprague Dawley rats underwent 180 min PET scans with arterial blood sampling. Reference tissue methods were evaluated on the basis of invasive kinetic models with metabolite-corrected arterial input functions. In vivo 5-HT2AR quantification with PET was validated by in vitro autoradiographic saturation experiments in the same animals. Overall brain uptake of [18F]altanserin was reliably quantified by invasive and non-invasive models with the cerebellum as reference region shown by linear correlation of outcome parameters. Unlike in humans, no lipophilic metabolites occurred so that brain activity derived solely from parent compound. PET data correlated very well with in vitro autoradiographic data of the same animals. [18F]Altanserin PET is a reliable tool for in vivo quantification of 5-HT2AR availability in albino rats. Models based on both blood input and reference tissue describe radiotracer kinetics adequately. Low cerebral tracer uptake might, however, cause restrictions in experimental usage.

  11. A cytoarchitecture-driven myelin model reveals area-specific signatures in human primary and secondary areas using ultra-high resolution in-vivo brain MRI.

    PubMed

    Dinse, J; Härtwich, N; Waehnert, M D; Tardif, C L; Schäfer, A; Geyer, S; Preim, B; Turner, R; Bazin, P-L

    2015-07-01

    This work presents a novel approach for modelling laminar myelin patterns in the human cortex in brain MR images on the basis of known cytoarchitecture. For the first time, it is possible to estimate intracortical contrast visible in quantitative ultra-high resolution MR images in specific primary and secondary cytoarchitectonic areas. The presented technique reveals different area-specific signatures which may help to study the spatial distribution of cortical T1 values and the distribution of cortical myelin in general. It may lead to a new discussion on the concordance of cyto- and myeloarchitectonic boundaries, given the absence of such concordance atlases. The modelled myelin patterns are quantitatively compared with data from human ultra-high resolution in-vivo 7T brain MR images (9 subjects). In the validation, the results are compared to one post-mortem brain sample and its ex-vivo MRI and histological data. Details of the analysis pipeline are provided. In the context of the increasing interest in advanced methods in brain segmentation and cortical architectural studies, the presented model helps to bridge the gap between the microanatomy revealed by classical histology and the macroanatomy visible in MRI. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  12. Alternative prediction methods of protein and energy evaluation of pig feeds.

    PubMed

    Święch, Ewa

    2017-01-01

    Precise knowledge of the actual nutritional value of individual feedstuffs and complete diets for pigs is important for efficient livestock production. Methods of assessment of protein and energy values in pig feeds have been briefly described. In vivo determination of protein and energy values of feeds in pigs are time-consuming, expensive and very often require the use of surgically-modified animals. There is a need for more simple, rapid, inexpensive and reproducible methods for routine feed evaluation. Protein and energy values of pig feeds can be estimated using the following alternative methods: 1) prediction equations based on chemical composition; 2) animal models as rats, cockerels and growing pigs for adult animals; 3) rapid methods, such as the mobile nylon bag technique and in vitro methods. Alternative methods developed for predicting the total tract and ileal digestibility of nutrients including amino acids in feedstuffs and diets for pigs have been reviewed. This article focuses on two in vitro methods that can be used for the routine evaluation of amino acid ileal digestibility and energy value of pig feeds and on factors affecting digestibility determined in vivo in pigs and by alternative methods. Validation of alternative methods has been carried out by comparing the results obtained using these methods with those acquired in vivo in pigs. In conclusion, energy and protein values of pig feeds may be estimated with satisfactory precision in rats and by the two- or three-step in vitro methods providing equations for the calculation of standardized ileal digestibility of amino acids and metabolizable energy content. The use of alternative methods of feed evaluation is an important way for reduction of stressful animal experiments.

  13. Longitudinal monitoring adipose-derived stem cell survival by PET imaging hexadecyl-4-{sup 124}I-iodobenzoate in rat myocardial infarction model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Min Hwan; School of Life Sciences and Biotechnology, Korea University, Seoul; Woo, Sang-Keun

    Highlights: • We developed a safe, simple and appropriate stem cell labeling method with {sup 124}I-HIB. • ADSC survival can be monitored with PET in MI model via direct labeling. • Tracking of ADSC labeled with {sup 124}I-HIB was possible for 3 days in MI model using PET. • ADSC viability and differentiation were not affected by {sup 124}I-HIB labeling. • Survival of ADSC in living bodies can be longitudinally tracked with PET imaging. - Abstract: This study aims to monitor how the change of cell survival of transplanted adipose-derived stem cells (ADSCs) responds to myocardial infarction (MI) via themore » hexadecyl-4-{sup 124}I-iodobenzoate ({sup 124}I-HIB) mediated direct labeling method in vivo. Stem cells have shown the potential to improve cardiac function after MI. However, monitoring of the fate of transplanted stem cells at target sites is still unclear. Rat ADSCs were labeled with {sup 124}I-HIB, and radiolabeled ADSCs were transplanted into the myocardium of normal and MI model. In the group of {sup 124}I-HIB-labeled ADSC transplantation, in vivo imaging was performed using small-animal positron emission tomography (PET)/computed tomography (CT) for 9 days. Twenty-one days post-transplantation, histopathological analysis and apoptosis assay were performed. ADSC viability and differentiation were not affected by {sup 124}I-HIB labeling. In vivo tracking of the {sup 124}I-HIB-labeled ADSCs was possible for 9 and 3 days in normal and MI model, respectively. Apoptosis of transplanted cells increased in the MI model compared than that in normal model. We developed a direct labeling agent, {sup 124}I-HIB, and first tried to longitudinally monitor transplanted stem cell to MI. This approach may provide new insights on the roles of stem cell monitoring in living bodies for stem cell therapy from pre-clinical studies to clinical trials.« less

  14. “Do-it-yourself in vitro vasculature that recapitulates in vivo geometries for investigating endothelial-blood cell interactions”

    PubMed Central

    Mannino, Robert G.; Myers, David R.; Ahn, Byungwook; Wang, Yichen; Margo Rollins; Gole, Hope; Lin, Angela S.; Guldberg, Robert E.; Giddens, Don P.; Timmins, Lucas H.; Lam, Wilbur A.

    2015-01-01

    Investigating biophysical cellular interactions in the circulation currently requires choosing between in vivo models, which are difficult to interpret due in part to the hemodynamic and geometric complexities of the vasculature; or in vitro systems, which suffer from non-physiologic assumptions and/or require specialized microfabrication facilities and expertise. To bridge that gap, we developed an in vitro “do-it-yourself” perfusable vasculature model that recapitulates in vivo geometries, such as aneurysms, stenoses, and bifurcations, and supports endothelial cell culture. These inexpensive, disposable devices can be created rapidly (<2 hours) with high precision and repeatability, using standard off-the-shelf laboratory supplies. Using these “endothelialized” systems, we demonstrate that spatial variation in vascular cell adhesion molecule (VCAM-1) expression correlates with the wall shear stress patterns of vascular geometries. We further observe that the presence of endothelial cells in stenoses reduces platelet adhesion but increases sickle cell disease (SCD) red blood cell (RBC) adhesion in bifurcations. Overall, our method enables researchers from all disciplines to study cellular interactions in physiologically relevant, yet simple-to-make, in vitro vasculature models. PMID:26202603

  15. Intrathoracic airway measurement: ex-vivo validation

    NASA Astrophysics Data System (ADS)

    Reinhardt, Joseph M.; Raab, Stephen A.; D'Souza, Neil D.; Hoffman, Eric A.

    1997-05-01

    High-resolution x-ray CT (HRCT) provides detailed images of the lungs and bronchial tree. HRCT-based imaging and quantitation of peripheral bronchial airway geometry provides a valuable tool for assessing regional airway physiology. Such measurements have been sued to address physiological questions related to the mechanics of airway collapse in sleep apnea, the measurement of airway response to broncho-constriction agents, and to evaluate and track the progression of disease affecting the airways, such as asthma and cystic fibrosis. Significant attention has been paid to the measurements of extra- and intra-thoracic airways in 2D sections from volumetric x-ray CT. A variety of manual and semi-automatic techniques have been proposed for airway geometry measurement, including the use of standardized display window and level settings for caliper measurements, methods based on manual or semi-automatic border tracing, and more objective, quantitative approaches such as the use of the 'half-max' criteria. A recently proposed measurements technique uses a model-based deconvolution to estimate the location of the inner and outer airway walls. Validation using a plexiglass phantom indicates that the model-based method is more accurate than the half-max approach for thin-walled structures. In vivo validation of these airway measurement techniques is difficult because of the problems in identifying a reliable measurement 'gold standard.' In this paper we report on ex vivo validation of the half-max and model-based methods using an excised pig lung. The lung is sliced into thin sections of tissue and scanned using an electron beam CT scanner. Airways of interest are measured from the CT images, and also measured with using a microscope and micrometer to obtain a measurement gold standard. The result show no significant difference between the model-based measurements and the gold standard; while the half-max estimates exhibited a measurement bias and were significantly different than the gold standard.

  16. The use of ex vivo human skin tissue for genotoxicity testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reus, Astrid A.; Usta, Mustafa; Krul, Cyrille A.M., E-mail: cyrille.krul@tno.nl

    2012-06-01

    As a result of the chemical legislation concerning the registration, evaluation, authorization and restriction of chemicals (REACH), and the Seventh Amendment to the Cosmetics Directive, which prohibits animal testing in Europe for cosmetics, alternative methods for safety evaluation of chemicals are urgently needed. Current in vitro genotoxicity assays are not sufficiently predictive for the in vivo situation, resulting in an unacceptably high number of misleading positives. For many chemicals and ingredients of personal care products the skin is the first site of contact, but there are no in vitro genotoxicity assays available in the skin for additional evaluation of positivemore » or equivocal responses observed in regulatory in vitro genotoxicity assays. In the present study ex vivo human skin tissue obtained from surgery was used for genotoxicity evaluation of chemicals by using the comet assay. Fresh ex vivo human skin tissue was cultured in an air–liquid interface and topically exposed to 20 chemicals, including true positive, misleading positive and true negative genotoxins. Based on the results obtained in the present study, the sensitivity, specificity and accuracy of the ex vivo skin comet assay to predict in vivo genotoxicity were 89%, 90% and 89%, respectively. Donor and experimental variability were mainly reflected in the magnitude of the response and not the difference between the presence and absence of a genotoxic response. The present study indicates that human skin obtained from surgery is a promising and robust model for safety evaluation of chemicals that are in direct contact with the skin. -- Highlights: ► We use human skin obtained from surgery for genotoxicity evaluation of chemicals. ► We use the comet assay as parameter for genotoxicity in ex vivo human skin. ► Sensitivity, specificity and accuracy to predict in vivo genotoxins are determined. ► Sensitivity, specificity and accuracy are 89%, 90% and 90%, respectively. ► The method is suitable for evaluation of chemicals that are in contact with skin.« less

  17. In vitro and in vivo correlation of disintegration and bitter taste masking using orally disintegrating tablet containing ion exchange resin-drug complex.

    PubMed

    Kim, Jong-Il; Cho, Sang-Min; Cui, Jing-Hao; Cao, Qing-Ri; Oh, Euichaul; Lee, Beom-Jin

    2013-10-15

    Although the taste-masking of bitter drug using ion exchange resin has been recognized, in vitro testing using an electronic tongue (e-Tongue) and in vivo bitterness test by human panel test was not fully understood. In case of orally disintegrating tablet (ODT) containing bitter medicine, in vitro and in vivo disintegration is also importance for dosage performance. Donepezil hydrochloride was chosen as a model drug due to its bitterness and requires rapid disintegration for the preparation of ODT. In this study, ion exchange resin drug complex (IRDC) at three different ratios (1:2, 1:1, 2:1) was prepared using a spray-drying method and then IRDC-loaded ODT containing superdisintegrants (crospovidone, croscarmellose sodium, and sodium starch glycolate) were prepared by the direct compression method. The physical properties and morphologies were then characterized by scanning electron microscopy (SEM), X-ray powder diffraction (PXRD) and electrophoretic laser scattering (ELS), respectively. The in vitro taste-masking efficiency was measured with an electronic tongue (e-Tongue). In vivo bitterness scale was also evaluated by human volunteers and then we defined new term, "bitterness index (BI)" to link in vitro e-Tongue. There was a good correlation of IRDC between in vitro e-Tongue values and in vivo BI. Furthermore, IRDC-loaded ODT showed good in vitro/in vivo correlation in the disintegration time. The optimal IRDC-loaded ODTs displayed similar drug release profiles to the reference tablet (Aricept(®) ODT) in release media of pH 1.2, pH 4.0, pH 6.8 and distilled water but had significantly better palatability in vivo taste-masking evaluation. The current IRDC-loaded ODT according to the in vitro and in vivo correlation of disintegration and bitter taste masking could provide platforms in ODT dosage formulations of donepezil hydrochloride for improved patient compliances. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Adenoviral Mediated Gene Transfer of IGF-1 Enhances Wound Healing and Induces Angiogenesis

    PubMed Central

    Balaji, S.; LeSaint, M.; Bhattacharya, S. S.; Moles, C.; Dhamija, Y.; Kidd, M.; Le, L.D.; King, A.; Shaaban, A.; Crombleholme, T. M.; Bollyky, P.; Keswani, S. G.

    2014-01-01

    Background Chronic wounds are characterized by a wound healing and neovascularization deficit. Strategies to increase neovascularization can significantly improve chronic wound healing. Insulin like growth factor (IGF-1) is reported to be a keratinocyte mitogen and is believed to induce angiogenesis via a vascular endothelial growth factor (VEGF) dependent pathway. Using a novel ex vivo human dermal wound model and a diabetic impaired wound healing murine model, we hypothesized that adenoviral over expression of IGF-1 (Ad-IGF-1) will enhance wound healing and induce angiogenesis through a VEGF dependent pathway. Methods Ex vivo: 6 mm full thickness punch biopsies were obtained from normal human skin, and 3 mm full thickness wounds were created at the center. Skin explants were maintained at air liquid interface. Db/db murine model: 8 mm full thickness dorsal wounds in diabetic (db/db) mice were created. Treatment groups in both human ex vivo and in vivo db/db wound models include 1×108 PFU of Ad-IGF-1 or Ad-LacZ, and PBS (n=4–5/group). Cytotoxicity (LDH) was quantified at days 3, 5 and 7 for the human ex vivo wound model. Epithelial gap closure (H&E; Trichrome), VEGF expression (ELISA) and capillary density (CD 31+ CAPS/HPF) were analyzed at day 7. Results In the human ex vivo organ culture, the adenoviral vectors did not demonstrate any significant difference in cytotoxicity compared to PBS. Ad-IGF-1 over expression significantly increases basal keratinocyte migration, with no significant effect on epithelial gap closure. There was a significant increase in capillary density in the Ad-IGF-1 wounds. However, there was no effect on VEGF levels in Ad-IGF-1 samples compared to controls. In db/db wounds, Ad-IGF-1 over expression significantly improves epithelial gap closure and granulation tissue with a dense cellular infiltrate compared to controls. Ad-IGF-1 also increases capillary density, again with no significant difference in VEGF levels in the wounds compared to control treatments. Conclusions In two different models, our data demonstrates that adenoviral mediated gene transfer of IGF-1 results in enhanced wound healing and induces angiogenesis via a VEGF-independent pathway. Understanding the underlying mechanisms of IGF-1 effects on angiogenesis may help produce novel therapeutics for chronic wounds or diseases characterized by a deficit in neovascularization. PMID:24725678

  19. Screening-level assays for potentially human-infectious environmental Legionella spp.

    EPA Science Inventory

    In spite of the fact that Legionella species can be isolated from nonclinical settings, there is no standard method to determine whether environmental legionellae may be infectious to humans. In this study, an in vivo murine model of pneumonia and three in vitro proliferation as...

  20. In vitro to in vivo extrapolation of hepatic metabolism in fish: An inter-laboratory comparison of in vitro methods - presentation

    EPA Science Inventory

    Chemical biotransformation represents the largest source of uncertainty in chemical bioaccumulation assessments. Model-based estimates of chemical bioconcentration in fish may be greatly improved by including biotransformation rates, as measured in vitro. Substrate depletion assa...

  1. Assessment of intensive care unit‐acquired weakness in young and old mice: An E. coli septic peritonitis model

    PubMed Central

    Hoogland, Inge C.M.; Wieske, Luuk; Weber, Nina C.; Verhamme, Camiel; Schultz, Marcus J.; van Schaik, Ivo N.; Horn, Janneke

    2015-01-01

    ABSTRACT Introduction: There are few reports of in vivo muscle strength measurements in animal models of ICU‐acquired weakness (ICU‐AW). In this study we investigated whether the Escherichia coli (E. coli) septic peritonitis mouse model may serve as an ICU‐AW model using in vivo strength measurements and myosin/actin assays, and whether development of ICU‐AW is age‐dependent in this model. Methods: Young and old mice were injected intraperitoneally with E. coli and treated with ceftriaxone. Forelimb grip strength was measured at multiple time points, and the myosin/actin ratio in muscle was determined. Results: E. coli administration was not associated with grip strength decrease, neither in young nor in old mice. In old mice, the myosin/actin ratio was lower in E. coli mice at t = 48 h and higher at t = 72 h compared with controls. Conclusions: This E. coli septic peritonitis mouse model did not induce decreased grip strength. In its current form, it seems unsuitable as a model for ICU‐AW. Muscle Nerve 53: 127–133, 2016 PMID:26015329

  2. Image-Based Predictive Modeling of Heart Mechanics.

    PubMed

    Wang, V Y; Nielsen, P M F; Nash, M P

    2015-01-01

    Personalized biophysical modeling of the heart is a useful approach for noninvasively analyzing and predicting in vivo cardiac mechanics. Three main developments support this style of analysis: state-of-the-art cardiac imaging technologies, modern computational infrastructure, and advanced mathematical modeling techniques. In vivo measurements of cardiac structure and function can be integrated using sophisticated computational methods to investigate mechanisms of myocardial function and dysfunction, and can aid in clinical diagnosis and developing personalized treatment. In this article, we review the state-of-the-art in cardiac imaging modalities, model-based interpretation of 3D images of cardiac structure and function, and recent advances in modeling that allow personalized predictions of heart mechanics. We discuss how using such image-based modeling frameworks can increase the understanding of the fundamental biophysics behind cardiac mechanics, and assist with diagnosis, surgical guidance, and treatment planning. Addressing the challenges in this field will require a coordinated effort from both the clinical-imaging and modeling communities. We also discuss future directions that can be taken to bridge the gap between basic science and clinical translation.

  3. First pass intestinal and liver metabolism of paracetamol in a microfluidic platform coupled with a mathematical modeling as a means of evaluating ADME processes in humans.

    PubMed

    Prot, Jean Matthieu; Maciel, Luis; Bricks, Thibault; Merlier, Franck; Cotton, Jérôme; Paullier, Patrick; Bois, Fréderic Yves; Leclerc, Eric

    2014-10-01

    We developed a microfluidic platform to investigate paracetamol intestinal and liver first pass metabolism. This approach was coupled with a mathematical model to estimate intrinsic in vitro parameters and to predict in vivo processes. The kinetic modeling estimated the paracetamol and paracetamol sulfate permeabilities, the sulfate and glucuronide effluxes in the intestine compartment. Based on a gut model, we estimated intrinsic intestinal clearance of between 26 and 77 L/h for paracetamol in humans, a permeability of 10 L/h, and a gut availability between 0.17 and 0.53 (compared to 0.95-1 in vivo). The role played by the liver in paracetamol metabolism was estimated via in vitro intrinsic clearances of 7.6, 13.6, and 11.5 µL/min/10(6) cells for HepG2/C3a, rat primary hepatocytes, and human primary hepatocytes, respectively. Based on a parallel tube model to describe the liver, the paracetamol hepatic clearance, and the paracetamol hepatic availability in humans were estimated at 6.5 mL/min/kg of bodyweight (BDW) and 0.7, respectively (when compared to 5 mL/min/kg of BDW and 0.77 to 0.88 for in vivo values, respectively). The drug availability was predicted ranging between 0.24 and 0.41 (0.88 in vivo). The overall approach provided a first step in an integrated strategy combining in silico/in vitro methods based on microfluidic for evaluating drug absorption, distribution and metabolism processes. © 2014 Wiley Periodicals, Inc.

  4. Tapered fiber optic applicator for laser ablation: Theoretical and experimental assessment of thermal effects on ex vivo model.

    PubMed

    Saccomandi, P; Di Matteo, F M; Schena, E; Quero, G; Massaroni, C; Giurazza, F; Costamagna, G; Silvestri, S

    2017-07-01

    Laser Ablation (LA) is a minimally invasive technique for tumor removal. The laser light is guided into the target tissue by a fiber optic applicator; thus the physical features of the applicator tip strongly influence size and shape of the tissue lesion. This study aims to verify the geometry of the lesion achieved by a tapered-tip applicator, and to investigate the percentage of thermally damaged cells induced by the tapered-tip fiber optic applicator. A theoretical model was implemented to simulate: i) the distribution of laser light fluence rate in the tissue through Monte Carlo method, ii) the induced temperature distribution, by means of the Bio Heat Equation, iii) the tissue injury, by Arrhenius integral. The results obtained by the implementation of the theoretical model were experimentally assessed. Ex vivo porcine liver underwent LA with tapered-tip applicator, at different laser settings (laser power of 1 W and 1.7 W, deposited energy equal to 330 J and 500 J, respectively). Almost spherical volume lesions were produced. The thermal damage was assessed by measuring the diameter of the circular-shaped lesion. The comparison between experimental results and theoretical prediction shows that the thermal damage discriminated by visual inspection always corresponds to a percentage of damaged cells of 96%. A tapered-tip applicator allows obtaining localized and reproducible damage close to spherical shape, whose diameter is related to the laser settings, and the simple theoretical model described is suitable to predict the effects, in terms of thermal damage, on ex vivo liver. Further trials should be addressed to adapt the model also on in vivo tissue, aiming to develop a tool useful to support the physician in clinical application of LA.

  5. Human induced pluripotent stem cells can reach complete terminal maturation: in vivo and in vitro evidence in the erythropoietic differentiation model

    PubMed Central

    Kobari, Ladan; Yates, Frank; Oudrhiri, Noufissa; Francina, Alain; Kiger, Laurent; Mazurier, Christelle; Rouzbeh, Shaghayegh; El-Nemer, Wassim; Hebert, Nicolas; Giarratana, Marie-Catherine; François, Sabine; Chapel, Alain; Lapillonne, Hélène; Luton, Dominique; Bennaceur-Griscelli, Annelise; Douay, Luc

    2012-01-01

    Background Human induced pluripotent stem cells offer perspectives for cell therapy and research models for diseases. We applied this approach to the normal and pathological erythroid differentiation model by establishing induced pluripotent stem cells from normal and homozygous sickle cell disease donors. Design and Methods We addressed the question as to whether these cells can reach complete erythroid terminal maturation notably with a complete switch from fetal to adult hemoglobin. Sickle cell disease induced pluripotent stem cells were differentiated in vitro into red blood cells and characterized for their terminal maturation in terms of hemoglobin content, oxygen transport capacity, deformability, sickling and adherence. Nucleated erythroblast populations generated from normal and pathological induced pluripotent stem cells were then injected into non-obese diabetic severe combined immunodeficiency mice to follow the in vivo hemoglobin maturation. Results We observed that in vitro erythroid differentiation results in predominance of fetal hemoglobin which rescues the functionality of red blood cells in the pathological model of sickle cell disease. We observed, in vivo, the switch from fetal to adult hemoglobin after infusion of nucleated erythroid precursors derived from either normal or pathological induced pluripotent stem cells into mice. Conclusions These results demonstrate that human induced pluripotent stem cells: i) can achieve complete terminal erythroid maturation, in vitro in terms of nucleus expulsion and in vivo in terms of hemoglobin maturation; and ii) open the way to generation of functionally corrected red blood cells from sickle cell disease induced pluripotent stem cells, without any genetic modification or drug treatment. PMID:22733021

  6. Research and development of a new RF-assisted device for bloodless rapid transection of the liver: Computational modeling and in vivo experiments

    PubMed Central

    Burdío, Fernando; Berjano, Enrique J; Navarro, Ana; Burdío, José M; Grande, Luis; Gonzalez, Ana; Cruz, Ignacio; Güemes, Antonio; Sousa, Ramón; Subirá, Jorge; Castiella, Tomás; Poves, Ignasi; Lequerica, Juan L

    2009-01-01

    Background Efficient and safe transection of biological tissue in liver surgery is strongly dependent on the ability to address both parenchymal division and hemostasis simultaneously. In addition to the conventional clamp crushing or finger fracture methods other techniques based on radiofrequency (RF) currents have been extensively employed to reduce intraoperative blood loss. In this paper we present our broad research plan for a new RF-assisted device for bloodless, rapid resection of the liver. Methods Our research plan includes computer modeling and in vivo studies. Computer modeling was based on the Finite Element Method (FEM) and allowed us to estimate the distribution of electrical power deposited in the tissue, along with assessing the effect of the characteristics of the device on the temperature profiles. Studies based on in vivo pig liver models provided a comparison of the performance of the new device with other techniques (saline-linked technology) currently employed in clinical practice. Finally, the plan includes a pilot clinical trial, in which both the new device and the accessory equipment are seen to comply with all safety requirements. Results The FEM results showed a high electrical gradient around the tip of the blade, responsible for the maximal increase of temperature at that point, where temperature reached 100°C in only 3.85 s. Other hot points with lower temperatures were located at the proximal edge of the device. Additional simulations with an electrically insulated blade produced more uniform and larger lesions (assessed as the 55°C isotherm) than the electrically conducting blade. The in vivo study, in turn, showed greater transection speed (3 ± 0 and 3 ± 1 cm2/min for the new device in the open and laparoscopic approaches respectively) and also lower blood loss (70 ± 74 and 26 ± 34 mL) during transection of the liver, as compared to saline-linked technology (2 ± 1 cm2/min with P = 0.002, and 527 ± 273 mL with P = 0.001). Conclusion A new RF-assisted device for bloodless, rapid liver resection was designed, built and tested. The results demonstrate the potential advantages of this device over others currently employed. PMID:19296852

  7. Rapid multislice T1 mapping of mouse myocardium: Application to quantification of manganese uptake in α-Dystrobrevin knockout mice.

    PubMed

    Jiang, Kai; Li, Wen; Li, Wei; Jiao, Sen; Castel, Laurie; Van Wagoner, David R; Yu, Xin

    2015-11-01

    The aim of this study was to develop a rapid, multislice cardiac T1 mapping method in mice and to apply the method to quantify manganese (Mn(2+)) uptake in a mouse model with altered Ca(2+) channel activity. An electrocardiography-triggered multislice saturation-recovery Look-Locker method was developed and validated both in vitro and in vivo. A two-dose study was performed to investigate the kinetics of T1 shortening, Mn(2+) relaxivity in myocardium, and the impact of Mn(2+) on cardiac function. The sensitivity of Mn(2+)-enhanced MRI in detecting subtle changes in altered Ca(2+) channel activity was evaluated in a mouse model with α-dystrobrevin knockout. Validation studies showed strong agreement between the current method and an established method. High Mn(2+) dose led to significantly accelerated T1 shortening. Heart rate decreased during Mn(2+) infusion, while ejection ratio increased slightly at the end of imaging protocol. No statistical difference in cardiac function was detected between the two dose groups. Mice with α-dystrobrevin knockout showed enhanced Mn(2+) uptake in vivo. In vitro patch-clamp study showed increased Ca(2+) channel activity. The saturation recovery method provides rapid T1 mapping in mouse hearts, which allowed sensitive detection of subtle changes in Mn(2+) uptake in α-dystrobrevin knockout mice. © 2014 Wiley Periodicals, Inc.

  8. Influence of the test method on in vitro drug release from intravitreal model implants containing dexamethasone or fluorescein sodium in poly (d,l-lactide-co-glycolide) or polycaprolactone.

    PubMed

    Stein, Sandra; Auel, Tobias; Kempin, Wiebke; Bogdahn, Malte; Weitschies, Werner; Seidlitz, Anne

    2018-06-01

    Sustained intravitreal dexamethasone (DX) administration with the FDA and EMA approved Ozurdex® implant is indicated for the treatment of macular edema and non-infectious uveitis. Since drug release after intravitreal application cannot be determined in vivo in human eyes, the characterization of drug release in vitro in addition to animal models is of great importance. The aim of this study was to provide information about the influence of the test method on the in vitro drug release from intravitreal model implants. The following test methods were used: a shaking incubator experiment in reagent tubes, the small volume USP apparatus 7, the Vitreous Model (VM) and a system simulating the impact of movement on the VM (Eye Movement System, EyeMoS). Cylindrical model implants composed of DX and PLGA (poly (d,l-lactide-co-glycolide)) and additional polycaprolactone (PCL) implants containing fluorescein sodium (FS) as a model substance were produced by hot melt extrusion and were cut to a length of approximately 6 mm. Drug release was studied in ringer buffer pH 7.4 and in a modified polyacrylamide gel (PAAG) as vitreous substitute. In combination with the VM, the shape, the gel structure and a partial liquefaction (50%) were simulated in vitro. Swelling, disintegration, fragmentation, surface enlargement and changes in shape of the PLGA model implants were observed during the drug release study. We experienced that not each of the test methods and media were suitable for drug release studies of the PLGA implants. Marked differences in the release profiles were observed depending on the employed test method. These results emphasize the necessity to understand the underlying in vivo processes and to transfer the knowledge about the release determining factors into reliable in vitro test systems. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Rapid in vivo testing of drug response in multiple myeloma made possible by xenograft to turkey embryos

    PubMed Central

    Farnoushi, Y; Cipok, M; Kay, S; Jan, H; Ohana, A; Naparstek, E; Goldstein, R S; Deutsch, V R

    2011-01-01

    Background: The best current xenograft model of multiple myeloma (MM) in immune-deficient non-obese diabetic/severe-combined immunodeficient mice is costly, animal maintenance is complex and several weeks are required to establish engraftment and study drug efficacy. More practical in vivo models may reduce time and drug development cost. We recently described a rapid low-cost xenograft model of human blood malignancies in pre-immune turkey. Here, we report application of this system for studying MM growth and the preclinical assessment of anticancer therapies. Methods: Cell lines and MM patient cells were injected intravenously into embryonic veins on embryonic day 11 (E11). Engraftment of human cells in haematopoietic organs was detected by quantitative real-time polymerase chain reaction, immunohistochemistry, flow cytometry and circulating free light chain. Results: Engraftment was detected after 1 week in all embryos injected with cell lines and in 50% of those injected with patient cells. Injection of bortezomib or lenalinomide 48 h after cell injection at therapeutic levels that were not toxic to the bone marrow dramatically reduced MM engraftment. Conclusion: The turkey embryo provides a practical, xenograft system to study MM and demonstrates the utility of this model for rapid and affordable testing therapeutics in vivo. With further development, this model may enable rapid, inexpensive personalised drug screening. PMID:22045188

  10. Nasopharyngeal Infection of Mice with Streptococcus pyogenes and In Vivo Detection of Superantigen Activity.

    PubMed

    Zeppa, Joseph J; Wakabayashi, Adrienne T; Kasper, Katherine J; Xu, Stacey X; Haeryfar, S M Mansour; McCormick, John K

    2016-01-01

    Streptococcus pyogenes is a globally prominent human-specific pathogen that is responsible for an enormous burden of infectious disease. Despite intensive experimental efforts to understand the molecular correlates that contribute to invasive infections, there has been less focus on S. pyogenes carriage and local infection of the nasopharynx. This chapter describes an acute nasopharyngeal infection model in mice that is utilized in our laboratory to study the role of superantigen toxins in the biology of S. pyogenes. We also describe a method to detect superantigen-specific T cell activation in vivo.

  11. Resurrection of DNA Function In Vivo from an Extinct Genome

    PubMed Central

    Pask, Andrew J.; Behringer, Richard R.; Renfree, Marilyn B.

    2008-01-01

    There is a burgeoning repository of information available from ancient DNA that can be used to understand how genomes have evolved and to determine the genetic features that defined a particular species. To assess the functional consequences of changes to a genome, a variety of methods are needed to examine extinct DNA function. We isolated a transcriptional enhancer element from the genome of an extinct marsupial, the Tasmanian tiger (Thylacinus cynocephalus or thylacine), obtained from 100 year-old ethanol-fixed tissues from museum collections. We then examined the function of the enhancer in vivo. Using a transgenic approach, it was possible to resurrect DNA function in transgenic mice. The results demonstrate that the thylacine Col2A1 enhancer directed chondrocyte-specific expression in this extinct mammalian species in the same way as its orthologue does in mice. While other studies have examined extinct coding DNA function in vitro, this is the first example of the restoration of extinct non-coding DNA and examination of its function in vivo. Our method using transgenesis can be used to explore the function of regulatory and protein-coding sequences obtained from any extinct species in an in vivo model system, providing important insights into gene evolution and diversity. PMID:18493600

  12. In vivo automated quantification of quality of apples during storage using optical coherence tomography images

    NASA Astrophysics Data System (ADS)

    Srivastava, Vishal; Dalal, Devjyoti; Kumar, Anuj; Prakash, Surya; Dalal, Krishna

    2018-06-01

    Moisture content is an important feature of fruits and vegetables. As 80% of apple content is water, so decreasing the moisture content will degrade the quality of apples (Golden Delicious). The computational and texture features of the apples were extracted from optical coherence tomography (OCT) images. A support vector machine with a Gaussian kernel model was used to perform automated classification. To evaluate the quality of wax coated apples during storage in vivo, our proposed method opens up the possibility of fully automated quantitative analysis based on the morphological features of apples. Our results demonstrate that the analysis of the computational and texture features of OCT images may be a good non-destructive method for the assessment of the quality of apples.

  13. A new ex vivo method to evaluate the performance of candidate MRI contrast agents: a proof-of-concept study.

    PubMed

    Candiota, Ana Paula; Acosta, Milena; Simões, Rui Vasco; Delgado-Goñi, Teresa; Lope-Piedrafita, Silvia; Irure, Ainhoa; Marradi, Marco; Bomati-Miguel, Oscar; Miguel-Sancho, Nuria; Abasolo, Ibane; Schwartz, Simó; Santamaria, Jesús; Penadés, Soledad; Arús, Carles

    2014-04-05

    Magnetic resonance imaging (MRI) plays an important role in tumor detection/diagnosis. The use of exogenous contrast agents (CAs) helps to improve the discrimination between lesion and neighbouring tissue, but most of the currently available CAs are non-specific. Assessing the performance of new, selective CAs requires exhaustive assays and large amounts of material. Accordingly, in a preliminary screening of new CAs, it is important to choose candidate compounds with good potential for in vivo efficiency. This screening method should reproduce as close as possible the in vivo environment. In this sense, a fast and reliable method to select the best candidate CAs for in vivo studies would minimize time and investment cost, and would benefit the development of better CAs. The post-mortem ex vivo relative contrast enhancement (RCE) was evaluated as a method to screen different types of CAs, including paramagnetic and superparamagnetic agents. In detail, sugar/gadolinium-loaded gold nanoparticles (Gd-GNPs) and iron nanoparticles (SPIONs) were tested. Our results indicate that the post-mortem ex vivo RCE of evaluated CAs, did not correlate well with their respective in vitro relaxivities. The results obtained with different Gd-GNPs suggest that the linker length of the sugar conjugate could modulate the interactions with cellular receptors and therefore the relaxivity value. A paramagnetic CA (GNP (E_2)), which performed best among a series of Gd-GNPs, was evaluated both ex vivo and in vivo. The ex vivo RCE was slightly worst than gadoterate meglumine (201.9 ± 9.3% versus 237 ± 14%, respectively), while the in vivo RCE, measured at the time-to-maximum enhancement for both compounds, pointed to GNP E_2 being a better CA in vivo than gadoterate meglumine. This is suggested to be related to the nanoparticule characteristics of the evaluated GNP. We have developed a simple, cost-effective relatively high-throughput method for selecting CAs for in vivo experiments. This method requires approximately 800 times less quantity of material than the amount used for in vivo administrations.

  14. A new ex vivo method to evaluate the performance of candidate MRI contrast agents: a proof-of-concept study

    PubMed Central

    2014-01-01

    Background Magnetic resonance imaging (MRI) plays an important role in tumor detection/diagnosis. The use of exogenous contrast agents (CAs) helps to improve the discrimination between lesion and neighbouring tissue, but most of the currently available CAs are non-specific. Assessing the performance of new, selective CAs requires exhaustive assays and large amounts of material. Accordingly, in a preliminary screening of new CAs, it is important to choose candidate compounds with good potential for in vivo efficiency. This screening method should reproduce as close as possible the in vivo environment. In this sense, a fast and reliable method to select the best candidate CAs for in vivo studies would minimize time and investment cost, and would benefit the development of better CAs. Results The post-mortem ex vivo relative contrast enhancement (RCE) was evaluated as a method to screen different types of CAs, including paramagnetic and superparamagnetic agents. In detail, sugar/gadolinium-loaded gold nanoparticles (Gd-GNPs) and iron nanoparticles (SPIONs) were tested. Our results indicate that the post-mortem ex vivo RCE of evaluated CAs, did not correlate well with their respective in vitro relaxivities. The results obtained with different Gd-GNPs suggest that the linker length of the sugar conjugate could modulate the interactions with cellular receptors and therefore the relaxivity value. A paramagnetic CA (GNP (E_2)), which performed best among a series of Gd-GNPs, was evaluated both ex vivo and in vivo. The ex vivo RCE was slightly worst than gadoterate meglumine (201.9 ± 9.3% versus 237 ± 14%, respectively), while the in vivo RCE, measured at the time-to-maximum enhancement for both compounds, pointed to GNP E_2 being a better CA in vivo than gadoterate meglumine. This is suggested to be related to the nanoparticule characteristics of the evaluated GNP. Conclusion We have developed a simple, cost-effective relatively high-throughput method for selecting CAs for in vivo experiments. This method requires approximately 800 times less quantity of material than the amount used for in vivo administrations. PMID:24708566

  15. Non-animal approaches for toxicokinetics in risk evaluations of food chemicals.

    PubMed

    Punt, Ans; Peijnenburg, Ad A C M; Hoogenboom, Ron L A P; Bouwmeester, Hans

    2017-01-01

    The objective of the present work was to review the availability and predictive value of non-animal toxicokinetic approaches and to evaluate their current use in European risk evaluations of food contaminants, additives and food contact materials, as well as pesticides and medicines. Results revealed little use of quantitative animal or human kinetic data in risk evaluations of food chemicals, compared with pesticides and medicines. Risk evaluations of medicines provided sufficient in vivo kinetic data from different species to evaluate the predictive value of animal kinetic data for humans. These data showed a relatively poor correlation between the in vivo bioavailability in rats and dogs versus that in humans. In contrast, in vitro (human) kinetic data have been demonstrated to provide adequate predictions of the fate of compounds in humans, using appropriate in vitro-in vivo scalers and by integration of in vitro kinetic data with in silico kinetic modelling. Even though in vitro kinetic data were found to be occasionally included within risk evaluations of food chemicals, particularly results from Caco-2 absorption experiments and in vitro data on gut-microbial conversions, only minor use of in vitro methods for metabolism and quantitative in vitro-in vivo extrapolation methods was identified. Yet, such quantitative predictions are essential in the development of alternatives to animal testing as well as to increase human relevance of toxicological risk evaluations. Future research should aim at further improving and validating quantitative alternative methods for kinetics, thereby increasing regulatory acceptance of non-animal kinetic data.

  16. Accurate reconstruction of 3D cardiac geometry from coarsely-sliced MRI.

    PubMed

    Ringenberg, Jordan; Deo, Makarand; Devabhaktuni, Vijay; Berenfeld, Omer; Snyder, Brett; Boyers, Pamela; Gold, Jeffrey

    2014-02-01

    We present a comprehensive validation analysis to assess the geometric impact of using coarsely-sliced short-axis images to reconstruct patient-specific cardiac geometry. The methods utilize high-resolution diffusion tensor MRI (DTMRI) datasets as reference geometries from which synthesized coarsely-sliced datasets simulating in vivo MRI were produced. 3D models are reconstructed from the coarse data using variational implicit surfaces through a commonly used modeling tool, CardioViz3D. The resulting geometries were then compared to the reference DTMRI models from which they were derived to analyze how well the synthesized geometries approximate the reference anatomy. Averaged over seven hearts, 95% spatial overlap, less than 3% volume variability, and normal-to-surface distance of 0.32 mm was observed between the synthesized myocardial geometries reconstructed from 8 mm sliced images and the reference data. The results provide strong supportive evidence to validate the hypothesis that coarsely-sliced MRI may be used to accurately reconstruct geometric ventricular models. Furthermore, the use of DTMRI for validation of in vivo MRI presents a novel benchmark procedure for studies which aim to substantiate their modeling and simulation methods using coarsely-sliced cardiac data. In addition, the paper outlines a suggested original procedure for deriving image-based ventricular models using the CardioViz3D software. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  17. Salicylic acid deposition from wash-off products: comparison of in vivo and porcine deposition models.

    PubMed

    Davies, M A

    2015-10-01

    Salicylic acid (SA) is a widely used active in anti-acne face wash products. Only about 1-2% of the total dose is actually deposited on skin during washing, and more efficient deposition systems are sought. The objective of this work was to develop an improved method, including data analysis, to measure deposition of SA from wash-off formulae. Full fluorescence excitation-emission matrices (EEMs) were acquired for non-invasive measurement of deposition of SA from wash-off products. Multivariate data analysis methods - parallel factor analysis and N-way partial least-squares regression - were used to develop and compare deposition models on human volunteers and porcine skin. Although both models are useful, there are differences between them. First, the range of linear response to dosages of SA was 60 μg cm(-2) in vivo compared to 25 μg cm(-2) on porcine skin. Second, the actual shape of the SA band was different between substrates. The methods employed in this work highlight the utility of the use of EEMs, in conjunction with multivariate analysis tools such as parallel factor analysis and multiway partial least-squares calibration, in determining sources of spectral variability in skin and quantification of exogenous species deposited on skin. The human model exhibited the widest range of linearity, but porcine model is still useful up to deposition levels of 25 μg cm(-2) or used with nonlinear calibration models. © 2015 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  18. Non-contact respiration monitoring for in-vivo murine micro computed tomography: characterization and imaging applications

    NASA Astrophysics Data System (ADS)

    Burk, Laurel M.; Lee, Yueh Z.; Wait, J. Matthew; Lu, Jianping; Zhou, Otto Z.

    2012-09-01

    A cone beam micro-CT has previously been utilized along with a pressure-tracking respiration sensor to acquire prospectively gated images of both wild-type mice and various adult murine disease models. While the pressure applied to the abdomen of the subject by this sensor is small and is generally without physiological effect, certain disease models of interest, as well as very young animals, are prone to atelectasis with added pressure, or they generate too weak a respiration signal with this method to achieve optimal prospective gating. In this work we present a new fibre-optic displacement sensor which monitors respiratory motion of a subject without requiring physical contact. The sensor outputs an analogue signal which can be used for prospective respiration gating in micro-CT imaging. The device was characterized and compared against a pneumatic air chamber pressure sensor for the imaging of adult wild-type mice. The resulting images were found to be of similar quality with respect to physiological motion blur; the quality of the respiration signal trace obtained using the non-contact sensor was comparable to that of the pressure sensor and was superior for gating purposes due to its better signal-to-noise ratio. The non-contact sensor was then used to acquire in-vivo micro-CT images of a murine model for congenital diaphragmatic hernia and of 11-day-old mouse pups. In both cases, quality CT images were successfully acquired using this new respiration sensor. Despite the presence of beam hardening artefacts arising from the presence of a fibre-optic cable in the imaging field, we believe this new technique for respiration monitoring and gating presents an opportunity for in-vivo imaging of disease models which were previously considered too delicate for established animal handling methods.

  19. In vivo biocompatibility of a new cyanine dye for ILM peeling

    PubMed Central

    Thaler, S; Haritoglou, C; Schuettauf, F; Choragiewicz, T; May, C A; Gekeler, F; Fischer, M D; Langhals, H; Schatz, A

    2015-01-01

    Purpose To investigate the biocompatibility of the new cyanine dye: 3,3′-Di-(4-sulfobutyl)-1,1,1′,1′-tetramethyl-di-1H-benz[e]indocarbocyanine (DSS) as a vital dye for intraocular application in an in vivo rat model and to evaluate the effects of this dye on retinal structure and function. Methods DSS at a concentration of 0.5% was applied via intravitreal injections to adult Brown Norway rats with BSS serving as a control. Retinal toxicity was assessed 7 days later by means of retinal ganglion cell (RGC) counts, light microscopy, optical coherence tomography (OCT), and electroretinography (ERG). Results No significant decrease in RGC numbers was observed. No structural changes of the central retina were observed either in vivo (OCT) or under light microscopy. ERGs detected a temporary reduction of retinal function 7 days after injection; this was no longer evident 14 days after injection. Conclusions DSS showed good biocompatibility in a well-established experimental in vivo setting and may be usable for intraocular surgery as an alternative to other cyanine dyes. In contrast to indocyanine green, it additionally offers fluorescence in the visual spectrum. Further studies with other animal models are needed before translation into clinical application. PMID:25523205

  20. In Vivo Defection of Thrombi with Indium-111-Labeled Platelets

    NASA Astrophysics Data System (ADS)

    Price, David C.; Lipton, Martin J.; Lusby, Robert J.; Engelstad, Barry L.; Stoney, Ronald J.; Prager, Robert J.; Hartmeyer, James A.; Holly, Anne S.

    1982-06-01

    The use of Indium-111-oxine labeled autologous platelets has been explored in a dog-catheter model, as well as in a variety of clinical disorders in man. Newly forming experimental thrombi in dogs label well during the first 45-90 minutes, then lose both label and thrombus mass in a manner consistent with fibrinolysis. Thrombus weight is linearly related to In-111 activity, so that in vivo scintigraphy will be a practical method to evaluate various thrombotic stimuli and anti-thrombotic interventions experimentally. Preformed thrombus, however, labels poorly and cannot be detected by imaging in this dog model. Initial clinical experience with a variety of arterial, venous and cardiac thrombotic states is reviewed, indicating some of the strengths and same of the potential weaknesses of this new scintigraphic technique.

  1. Evaluation of diffusion kurtosis imaging in ex vivo hypomyelinated mouse brains.

    PubMed

    Kelm, Nathaniel D; West, Kathryn L; Carson, Robert P; Gochberg, Daniel F; Ess, Kevin C; Does, Mark D

    2016-01-01

    Diffusion tensor imaging (DTI), diffusion kurtosis imaging (DKI), and DKI-derived white matter tract integrity metrics (WMTI) were experimentally evaluated ex vivo through comparisons to histological measurements and established magnetic resonance imaging (MRI) measures of myelin in two knockout mouse models with varying degrees of hypomyelination. DKI metrics of mean and radial kurtosis were found to be better indicators of myelin content than conventional DTI metrics. The biophysical WMTI model based on the DKI framework reported on axon water fraction with good accuracy in cases with near normal axon density, but did not provide additional specificity to myelination. Overall, DKI provided additional information regarding white matter microstructure compared with DTI, making it an attractive method for future assessments of white matter development and pathology. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. The use of rats and mice as animal models in ex vivo bone growth and development studies

    PubMed Central

    Abubakar, A. A.; Noordin, M. M.; Azmi, T. I.; Kaka, U.

    2016-01-01

    In vivo animal experimentation has been one of the cornerstones of biological and biomedical research, particularly in the field of clinical medicine and pharmaceuticals. The conventional in vivo model system is invariably associated with high production costs and strict ethical considerations. These limitations led to the evolution of an ex vivo model system which partially or completely surmounted some of the constraints faced in an in vivo model system. The ex vivo rodent bone culture system has been used to elucidate the understanding of skeletal physiology and pathophysiology for more than 90 years. This review attempts to provide a brief summary of the historical evolution of the rodent bone culture system with emphasis on the strengths and limitations of the model. It encompasses the frequency of use of rats and mice for ex vivo bone studies, nutritional requirements in ex vivo bone growth and emerging developments and technologies. This compilation of information could assist researchers in the field of regenerative medicine and bone tissue engineering towards a better understanding of skeletal growth and development for application in general clinical medicine. Cite this article: A. A. Abubakar, M. M. Noordin, T. I. Azmi, U. Kaka, M. Y. Loqman. The use of rats and mice as animal models in ex vivo bone growth and development studies. Bone Joint Res 2016;5:610–618. DOI: 10.1302/2046-3758.512.BJR-2016-0102.R2. PMID:27965220

  3. Quantifying shape changes of silicone breast implants in a murine model using in vivo micro-CT.

    PubMed

    Anderson, Emily E; Perilli, Egon; Carati, Colin J; Reynolds, Karen J

    2017-08-01

    A major complication of silicone breast implants is the formation of a capsule around the implant known as capsular contracture which results in the distortion of the implant. Recently, a mouse model for studying capsular contracture was examined using micro-computed tomography (micro-CT), however, only qualitative changes were reported. The aim of this study was to develop a quantitative method for comparing the shape changes of silicone implants using in vivo micro-CT. Mice were bilaterally implanted with silicone implants and underwent ionizing radiation to induce capsular contracture. On day 28 post-surgery mice were examined in vivo using micro-CT. The reconstructed cross-section images were visually inspected to identify distortion. Measurements were taken in 2D and 3D to quantify the shape of the implants in the normal (n = 11) and distorted (n = 5) groups. The degree of anisotropy was significantly higher in the distorted implants in the transaxial view (0.99 vs. 1.19, p = 0.002) and the y-axis lengths were significantly shorter in the sagittal (9.27 mm vs. 8.55 mm, p = 0.015) and coronal (9.24 mm vs. 8.76 mm, p = 0.031) views, indicating a deviation from the circular cross-section and shortening of the long axis. The 3D analysis revealed a significantly lower average thickness (sphere-fitting method) in distorted implants (6.86 mm vs. 5.49 mm, p = 0.002), whereas the volume and surface area did not show significant changes. Statistically significant differences between normal and distorted implants were found in 2D and 3D using distance measurements performed via micro-CT. This objective analysis method can be useful for a range of studies involving deformable implants using in vivo micro-CT. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1447-1452, 2017. © 2016 Wiley Periodicals, Inc.

  4. Pyruvate sensitizes pancreatic tumors to hypoxia-activated prodrug TH-302.

    PubMed

    Wojtkowiak, Jonathan W; Cornnell, Heather C; Matsumoto, Shingo; Saito, Keita; Takakusagi, Yoichi; Dutta, Prasanta; Kim, Munju; Zhang, Xiaomeng; Leos, Rafael; Bailey, Kate M; Martinez, Gary; Lloyd, Mark C; Weber, Craig; Mitchell, James B; Lynch, Ronald M; Baker, Amanda F; Gatenby, Robert A; Rejniak, Katarzyna A; Hart, Charles; Krishna, Murali C; Gillies, Robert J

    2015-01-01

    Hypoxic niches in solid tumors harbor therapy-resistant cells. Hypoxia-activated prodrugs (HAPs) have been designed to overcome this resistance and, to date, have begun to show clinical efficacy. However, clinical HAPs activity could be improved. In this study, we sought to identify non-pharmacological methods to acutely exacerbate tumor hypoxia to increase TH-302 activity in pancreatic ductal adenocarcinoma (PDAC) tumor models. Three human PDAC cell lines with varying sensitivity to TH-302 (Hs766t > MiaPaCa-2 > SU.86.86) were used to establish PDAC xenograft models. PDAC cells were metabolically profiled in vitro and in vivo using the Seahorse XF system and hyperpolarized (13)C pyruvate MRI, respectively, in addition to quantitative immunohistochemistry. The effect of exogenous pyruvate on tumor oxygenation was determined using electroparamagnetic resonance (EPR) oxygen imaging. Hs766t and MiaPaCa-2 cells exhibited a glycolytic phenotype in comparison to TH-302 resistant line SU.86.86. Supporting this observation is a higher lactate/pyruvate ratio in Hs766t and MiaPaCa xenografts as observed during hyperpolarized pyruvate MRI studies in vivo. Coincidentally, response to exogenous pyruvate both in vitro (Seahorse oxygen consumption) and in vivo (EPR oxygen imaging) was greatest in Hs766t and MiaPaCa models, possibly due to a higher mitochondrial reserve capacity. Changes in oxygen consumption and in vivo hypoxic status to pyruvate were limited in the SU.86.86 model. Combination therapy of pyruvate plus TH-302 in vivo significantly decreased tumor growth and increased survival in the MiaPaCa model and improved survival in Hs766t tumors. Using metabolic profiling, functional imaging, and computational modeling, we show improved TH-302 activity by transiently increasing tumor hypoxia metabolically with exogenous pyruvate. Additionally, this work identified a set of biomarkers that may be used clinically to predict which tumors will be most responsive to pyruvate + TH-302 combination therapy. The results of this study support the concept that acute increases in tumor hypoxia can be beneficial for improving the clinical efficacy of HAPs and can positively impact the future treatment of PDAC and other cancers.

  5. Effects of varying dietary ratios of corn silage to alfalfa silage on digestion of neutral detergent fiber in lactating dairy cows.

    PubMed

    Lopes, F; Cook, D E; Combs, D K

    2015-09-01

    An in vivo study was performed to test an in vitro procedure and model that predicts total-tract neutral detergent fiber (NDF) digestibility for lactating dairy cattle. Corn silage (CS) and alfalfa silage (AS) were used as forages for this study. These forages had similar NDF composition, but fiber in the CS contained less indigestible NDF compared with AS (35.5 and 47.8% of indigestible NDF, respectively). The in vitro method estimated rate of digestion of alfalfa potentially digestible NDF to be approximately 2 times faster than CS fiber (6.11 and 3.21%/h, respectively). Four diets were formulated containing different proportions of CS to AS: 100CS:0AS, 67CS:33AS, 33CS:67AS, and 0CS:100AS, as percentage of diet DM basis. The objective was to construct diets that contained approximately similar levels of NDF but with different pool sizes and rates of digestion of potentially digestible NDF. Diets were fed to 8 ruminally cannulated, multiparous, lactating dairy cows in a replicated 4×4 Latin square with 21-d periods. Total-tract fiber digestibility and fiber digestion kinetic parameters observed in vivo were compared with the values predicted by the in vitro assay and model. Total-tract NDF digestibility coefficients were similar (41.8 and 40.6% of total NDF) for the in vitro and in vivo methods, respectively. As the proportion of dietary alfalfa increased, the digestibility of NDF increased. The rate of digestion of potentially digestible NDF predicted from the in vitro assay was also similar to what was observed in vivo. Results suggest that the in vitro total-tract NDF digestibility model could be used to predict rate of fiber digestion and NDF digestibility for lactating dairy cattle. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  6. Validating Whole-Airway CFD Predictions of DPI Aerosol Deposition at Multiple Flow Rates

    PubMed Central

    Tian, Geng; Khajeh-Hosseini-Dalasm, Navvab; Hindle, Michael

    2016-01-01

    Abstract Background: The objective of this study was to compare aerosol deposition predictions of a new whole-airway CFD model with available in vivo data for a dry powder inhaler (DPI) considered across multiple inhalation waveforms, which affect both the particle size distribution (PSD) and particle deposition. Methods: The Novolizer DPI with a budesonide formulation was selected based on the availability of 2D gamma scintigraphy data in humans for three different well-defined inhalation waveforms. Initial in vitro cascade impaction experiments were conducted at multiple constant (square-wave) particle sizing flow rates to characterize PSDs. The whole-airway CFD modeling approach implemented the experimentally determined PSDs at the point of aerosol formation in the inhaler. Complete characteristic airway geometries for an adult were evaluated through the lobar bronchi, followed by stochastic individual pathway (SIP) approximations through the tracheobronchial region and new acinar moving wall models of the alveolar region. Results: It was determined that the PSD used for each inhalation waveform should be based on a constant particle sizing flow rate equal to the average of the inhalation waveform's peak inspiratory flow rate (PIFR) and mean flow rate [i.e., AVG(PIFR, Mean)]. Using this technique, agreement with the in vivo data was acceptable with <15% relative differences averaged across the three regions considered for all inhalation waveforms. Defining a peripheral to central deposition ratio (P/C) based on alveolar and tracheobronchial compartments, respectively, large flow-rate-dependent differences were observed, which were not evident in the original 2D in vivo data. Conclusions: The agreement between the CFD predictions and in vivo data was dependent on accurate initial estimates of the PSD, emphasizing the need for a combination in vitro–in silico approach. Furthermore, use of the AVG(PIFR, Mean) value was identified as a potentially useful method for characterizing a DPI aerosol at a constant flow rate. PMID:27082824

  7. [An experimental study on the Chinese lung adenocarcinoma cell clone CPA-Yang1-BR with brain metastasis potency in nude mice and in vivo imaging research].

    PubMed

    Lei, Bei; Cao, Jie; Shen, Jie; Zhao, Lanxiang; Liang, Sheng; Meng, Qinggang; Xie, Wenhui; Yang, Shunfang

    2013-08-20

    Lung cancer is the leading cause of cancer-related death in men and women. It is also the most common cause of brain metastases. A brain metastasis model is difficult to be established because of the presence of the blood-brain barrier (BBB) and the lack of optimal methods for detecting brain metastasis in nude mice. Thus, the establishment of a Chinese lung adenocarcinoma cell line and its animal model with brain metastasis potency and in vivo research is of great significance. CPA-Yang1 cells were obtained from a patient with human lung adenocarcinoma by lentiviral vector-mediated transfection of green fluorescence protein. Intracardiac inoculation of the cells was performed in nude mice, and brain metastatic lesions were detected using micro ¹⁸F FDG-PET/CT scanners, small animal in vivo imaging system for fluorescence, radionuclide and X ray fused imaging, magnetic resonance imaging (MRI) with sense body detection, and resection. The samples were divided into two parts for cell culture and histological diagnosis. The process was repeated in vivo and in vitro for four cycles to obtain a novel cell clone, CPA-Yang1-BR. A novel cell clone, CPA-Yang1-BR, was obtained with a brain metastatic rate of 50%. The use of MRI for the detection of brain metastases has obvious advantages. An experimental Chinese lung adenocarcinoma cell clone (CPA-Yang1-BR) and its animal model with brain metastasis potency in nude mice were established. MRI with sense body or micro MRI may be used as a sensitive, accurate, and noninvasive method to detect experimental brain metastases in intact live immunodeficient mice. The results of this study may serve as a technical platform for brain metastases from lung adenocarcinoma.

  8. Embryonic stem cell therapy improves bone quality in a model of impaired fracture healing in the mouse; tracked temporally using in vivo micro-CT.

    PubMed

    Taiani, J T; Buie, H R; Campbell, G M; Manske, S L; Krawetz, R J; Rancourt, D E; Boyd, S K; Matyas, J R

    2014-07-01

    In the current study, we used an estrogen-deficient mouse model of osteoporosis to test the efficacy of a cell-generated bone tissue construct for bone augmentation of an impaired healing fracture. A reduction in new bone formation at the defect site was observed in ovariectomized fractures compared to the control group using repeated measures in vivo micro-computed tomography (μCT) imaging over 4 weeks. A significant increase in the bone mineral density (BMD), trabecular bone volume ratio, and trabecular number, thickness and connectivity were associated with fracture repair in the control group, whereas the fractured bones of the ovariectomized mice exhibited a loss in all of these parameters (p<0.001). In a separate group, ovariectomized fractures were treated with murine embryonic stem (ES) cell-derived osteoblasts loaded in a three-dimensional collagen I gel and recovery of the bone at the defect site was observed. A significant increase in the trabecular bone volume ratio (p<0.001) and trabecular number (p<0.01) was observed by 4 weeks in the fractures treated with cell-loaded collagen matrix compared to those treated with collagen I alone. The stem cell-derived osteoblasts were identified at the fracture site at 4 weeks post-implantation through in situ hybridization histochemistry. Although this cell tracking method was effective, the formation of an ectopic cellular nodule adjacent to the knee joints of two mice suggested that alternative in vivo cell tracking methods should be employed in order to definitively assess migration of the implanted cells. To our knowledge, this study is the first of its kind to examine the efficacy of stem cell therapy for fracture repair in an osteoporosis-related fracture model in vivo. The findings presented provide novel insight into the use of stem cell therapies for bone injuries. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Modeling the measurements of cochlear microcirculation and hearing function after loud noise.

    PubMed

    Arpornchayanon, Warangkana; Canis, Martin; Suckfuell, Markus; Ihler, Fritz; Olzowy, Bernhard; Strieth, Sebastian

    2011-09-01

    Recent findings support the crucial role of microcirculatory disturbance and ischemia for hearing impairment especially after noise-induced hearing loss (NIHL). The aim of this study was to establish an animal model for in vivo analysis of cochlear microcirculation and hearing function after a loud noise to allow precise measurements of both parameters in vivo. Randomized controlled trial. Setting. Animal study. Subjects and Methods. After assessment of normacusis (0 minutes) using evoked auditory brainstem responses (ABRs), noise (106-dB sound pressure level [SPL]) was applied to both ears in 6 guinea pigs for 30 minutes while unexposed animals served as controls. In vivo fluorescence microscopy of the stria vascularis capillaries was performed after surgical exposure of 1 cochlea. ABR measurements were derived from the contralateral ear. After noise exposure, red blood cell velocity was reduced significantly by 24.3% (120 minutes) and further decreased to 44.5% at the end of the observation (210 minutes) in contrast to stable control measurements. Vessel diameters were not affected in both groups. A gradual decrease of segmental blood flow became significant (38.1%) after 150 minutes compared with controls. Hearing thresholds shifted significantly from 20.0 ± 5.5 dB SPL (0 minutes) to 32.5 ± 4.2 dB SPL (60 minutes) only in animals exposed to loud noise. With regard to novel treatments targeting the stria vascularis in NIHL, this standardized model allows us to analyze in detail cochlear microcirculation and hearing function in vivo.

  10. Comparison of the Developmental and Acute Neurotoxicity of a Library of Organophosphorus Pesticides Using a Vertebrate Behavioral Assay

    EPA Science Inventory

    The U.S. Environmental Protection Agency is evaluating methods to screen and prioritize organophosphorus pesticides for neurotoxicity using behavioral tests in an in vivo, vertebrate, medium-throughput model (zebrafish; Danio rerio). Our behavioral testing paradigm assesses the e...

  11. NCCT ToxCast Program for Nanomaterial Prioritization: High-Throughput Screening, Consideration of Exposure, and Bioactivity Profiling/Modeling

    EPA Science Inventory

    Find relationships between bioactivities and NM characteristics or testing conditions. Recommend a dose metric for NMs in vitro studies. Establish associations to in vivo toxicity or pathways identified from testing of conventional chemicals with ToxCast HTS methods. May be abl...

  12. Role of Metabolomics in Environmental Chemical Exposure and Risk Assessment

    EPA Science Inventory

    The increasing demand for the reduction, replacement, and refinement of the use of animal models in exposure assessments has stimulated the pursuit of alternative methods. This has included not only the use of the in vitro systems (e.g., cell cultures) in lieu of in vivo whole an...

  13. EDC testing in the future: Exploring roles of pathway-based in silico, in vitro and in vivo methods

    EPA Science Inventory

    Many thoroughly validated, robust tests with both mammalian and non-mammalian models have been developed to identify chemicals with the potential to impact endocrine pathways associated with the hypothalamic-pituitary-gonadal (HPG) and thyroidal axes. In the US, for example, the...

  14. AN IN VIVO MICRODIALYSIS METHOD FOR THE QUALITATIVE ANALYSIS OF HEPATIC PHASE I METABOLITES OF PHENOL IN RAINBOW TROUT (ONCORHYNCHUS MYKISS)

    EPA Science Inventory

    Development of reliable and accurate methodologies for determination of xenobiotic hepatic biotransformation rate and capacity parameters is important to the derivation of precise physiologically-based toxicokinetic (PB-TK) models. Biotransformation data incorporated into PB-TK m...

  15. New Alcohol and Onyx Mixture for Embolization: Feasibility and Proof of Concept in Both In Vitro and In Vivo Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saeed Kilani, Mohammad, E-mail: msaeedkilani@gmail.com, E-mail: mohammadalikilani@yahoo.com; Zehtabi, Fatemeh, E-mail: fatemeh.zehtabi@gmail.com; Lerouge, Sophie, E-mail: Sophie.Lerouge@etsmtl.ca

    IntroductionOnyx and ethanol are well-known embolic and sclerotic agents that are frequently used in embolization. These agents present advantages and disadvantages regarding visibility, injection control and penetration depth. Mixing both products might yield a new product with different characteristics. The aim of this study is to evaluate the injectability, radiopacity, and mechanical and occlusive properties of different mixtures of Onyx 18 and ethanol in vitro and in vivo (in a swine model).Materials and MethodsVarious Onyx 18 and ethanol formulations were prepared and tested in vitro for their injectability, solidification rate and shrinkage, cohesion and occlusive properties. In vivo tests weremore » performed using 3 swine. Ease of injection, radiopacity, cohesiveness and penetration were analyzed using fluoroscopy and high-resolution CT.ResultsAll mixtures were easy to inject through a microcatheter with no resistance or blockage in vitro and in vivo. The 50%-ethanol mixture showed delayed copolymerization with fragmentation and proximal occlusion. The 75%-ethanol mixture showed poor radiopacity in vivo and was not tested in vitro. The 25%-ethanol mixture showed good occlusive properties and accepted penetration and radiopacity.ConclusionMixing Onyx and ethanol is feasible. The mixture of 25% of ethanol and 75% of Onyx 18 could be a new sclero-embolic agent. Further research is needed to study the chemical changes of the mixture, to confirm the significance of the added sclerotic effect and to find out the ideal mixture percentages.« less

  16. In vivo neuronal calcium imaging in C. elegans.

    PubMed

    Chung, Samuel H; Sun, Lin; Gabel, Christopher V

    2013-04-10

    The nematode worm C. elegans is an ideal model organism for relatively simple, low cost neuronal imaging in vivo. Its small transparent body and simple, well-characterized nervous system allows identification and fluorescence imaging of any neuron within the intact animal. Simple immobilization techniques with minimal impact on the animal's physiology allow extended time-lapse imaging. The development of genetically-encoded calcium sensitive fluorophores such as cameleon and GCaMP allow in vivo imaging of neuronal calcium relating both cell physiology and neuronal activity. Numerous transgenic strains expressing these fluorophores in specific neurons are readily available or can be constructed using well-established techniques. Here, we describe detailed procedures for measuring calcium dynamics within a single neuron in vivo using both GCaMP and cameleon. We discuss advantages and disadvantages of both as well as various methods of sample preparation (animal immobilization) and image analysis. Finally, we present results from two experiments: 1) Using GCaMP to measure the sensory response of a specific neuron to an external electrical field and 2) Using cameleon to measure the physiological calcium response of a neuron to traumatic laser damage. Calcium imaging techniques such as these are used extensively in C. elegans and have been extended to measurements in freely moving animals, multiple neurons simultaneously and comparison across genetic backgrounds. C. elegans presents a robust and flexible system for in vivo neuronal imaging with advantages over other model systems in technical simplicity and cost.

  17. A Novel Two-Step Hierarchical Quantitative Structure–Activity Relationship Modeling Work Flow for Predicting Acute Toxicity of Chemicals in Rodents

    PubMed Central

    Zhu, Hao; Ye, Lin; Richard, Ann; Golbraikh, Alexander; Wright, Fred A.; Rusyn, Ivan; Tropsha, Alexander

    2009-01-01

    Background Accurate prediction of in vivo toxicity from in vitro testing is a challenging problem. Large public–private consortia have been formed with the goal of improving chemical safety assessment by the means of high-throughput screening. Objective A wealth of available biological data requires new computational approaches to link chemical structure, in vitro data, and potential adverse health effects. Methods and results A database containing experimental cytotoxicity values for in vitro half-maximal inhibitory concentration (IC50) and in vivo rodent median lethal dose (LD50) for more than 300 chemicals was compiled by Zentralstelle zur Erfassung und Bewertung von Ersatz- und Ergaenzungsmethoden zum Tierversuch (ZEBET; National Center for Documentation and Evaluation of Alternative Methods to Animal Experiments). The application of conventional quantitative structure–activity relationship (QSAR) modeling approaches to predict mouse or rat acute LD50 values from chemical descriptors of ZEBET compounds yielded no statistically significant models. The analysis of these data showed no significant correlation between IC50 and LD50. However, a linear IC50 versus LD50 correlation could be established for a fraction of compounds. To capitalize on this observation, we developed a novel two-step modeling approach as follows. First, all chemicals are partitioned into two groups based on the relationship between IC50 and LD50 values: One group comprises compounds with linear IC50 versus LD50 relationships, and another group comprises the remaining compounds. Second, we built conventional binary classification QSAR models to predict the group affiliation based on chemical descriptors only. Third, we developed k-nearest neighbor continuous QSAR models for each subclass to predict LD50 values from chemical descriptors. All models were extensively validated using special protocols. Conclusions The novelty of this modeling approach is that it uses the relationships between in vivo and in vitro data only to inform the initial construction of the hierarchical two-step QSAR models. Models resulting from this approach employ chemical descriptors only for external prediction of acute rodent toxicity. PMID:19672406

  18. In vitro porcine blood-brain barrier model for permeability studies: pCEL-X software pKa(FLUX) method for aqueous boundary layer correction and detailed data analysis.

    PubMed

    Yusof, Siti R; Avdeef, Alex; Abbott, N Joan

    2014-12-18

    In vitro blood-brain barrier (BBB) models from primary brain endothelial cells can closely resemble the in vivo BBB, offering valuable models to assay BBB functions and to screen potential central nervous system drugs. We have recently developed an in vitro BBB model using primary porcine brain endothelial cells. The model shows expression of tight junction proteins and high transendothelial electrical resistance, evidence for a restrictive paracellular pathway. Validation studies using small drug-like compounds demonstrated functional uptake and efflux transporters, showing the suitability of the model to assay drug permeability. However, one limitation of in vitro model permeability measurement is the presence of the aqueous boundary layer (ABL) resulting from inefficient stirring during the permeability assay. The ABL can be a rate-limiting step in permeation, particularly for lipophilic compounds, causing underestimation of the permeability. If the ABL effect is ignored, the permeability measured in vitro will not reflect the permeability in vivo. To address the issue, we explored the combination of in vitro permeability measurement using our porcine model with the pKa(FLUX) method in pCEL-X software to correct for the ABL effect and allow a detailed analysis of in vitro (transendothelial) permeability data, Papp. Published Papp using porcine models generated by our group and other groups are also analyzed. From the Papp, intrinsic transcellular permeability (P0) is derived by simultaneous refinement using a weighted nonlinear regression, taking into account permeability through the ABL, paracellular permeability and filter restrictions on permeation. The in vitro P0 derived for 22 compounds (35 measurements) showed good correlation with P0 derived from in situ brain perfusion data (r(2)=0.61). The analysis also gave evidence for carrier-mediated uptake of naloxone, propranolol and vinblastine. The combination of the in vitro porcine model and the software analysis provides a useful tool to better predict BBB permeability in vivo and gain better mechanistic information about BBB permeation. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  19. Correlation Between An In-vitro Method And An In-vivo Method In Assessing Bioavailable Arsenic In Two Pesticide-Amended Soils

    NASA Astrophysics Data System (ADS)

    Quazi, S.; Sarkar, D.; Sylvia, V.; Datta, R.

    2006-05-01

    Health risk assessment of Arsenic (As) enriched soil requires the estimation of bioavailable fraction of total metal. Research has been conducted to gain a better understanding of the relationship between metal availability and risk assessment. Some baseline risk assessments developed for contaminated sites have used the conservative assumption that all (i.e. 100%) of the As present in soils and wastes is bioavailable, due to tremendous cost associated with in-vivo bioavailability studies. This potentially overestimates the actual health risk, elevating the expenses associated with site cleanup. Health risk from direct exposure to soil-As via the hand-to-mouth exposure route is restricted only to those fractions of As in the soil that are available to the human gastrointestinal system. A reasonable approach is to develop in-vitro methods that simulate the complex and dynamic human gastrointestinal system and correlate well with the results of in-vivo method. Thus this study aims in addressing the potential of one such in-vitro method developed by our research group in assessing the bioavailability of soil-As. Two soils with drastically different chemical characteristics in regards to As reactivity (Immokalee-low As retention capacity; Millhopper-high As retention capacity) spiked with a pesticide (sodium arsenate) were used. Soils were amended at two rates representing concentrations typically found at Superfund sites: 675 and 1500 mg/kg of As. In-vitro bioavailability experiments were performed in order to obtain an estimate of the amount of As likely to be available in the human gastrointestinal system as well as the fraction potentially absorbed onto the intestinal linings. Following the in-vitro study selective in-vivo bioavailability studies using As-contaminated soils were conducted on male and female mice to validate the in-vitro results via comparison with the in-vivo data. Soils were administered orally to the BALB/c mice immediately after spiking. Treatments comprised of a soil group (As in soil), a positive control group (only As) and a negative control group (no soil, no As). Blood samples were collected at different time periods to determine As concentrations. Correlation between the in-vitro and in-vivo data was determined. Information obtained from this study will serve as the first step towards the future development of a semi-quantitative model for predicting bioavailable As. This in turn will result in designing appropriate, cost-effective remedial strategies for As contaminated sites. Keywords: Bioavailability, In-vitro, In-vivo, Arsenic, Soil, Risk Assessment

  20. Disease quantification in dermatology: in vivo near-infrared spectroscopy measures correlate strongly with the clinical assessment of psoriasis severity

    NASA Astrophysics Data System (ADS)

    Greve, Tanja Maria; Kamp, Søren; Jemec, Gregor B. E.

    2013-03-01

    Accurate documentation of disease severity is a prerequisite for clinical research and the practice of evidence-based medicine. The quantification of skin diseases such as psoriasis currently relies heavily on clinical scores. Although these clinical scoring methods are well established and very useful in quantifying disease severity, they require an extensive clinical experience and carry a risk of subjectivity. We explore the opportunity to use in vivo near-infrared (NIR) spectra as an objective and noninvasive method for local disease severity assessment in 31 psoriasis patients in whom selected plaques were scored clinically. A partial least squares (PLS) regression model was used to analyze and predict the severity scores on the NIR spectra of psoriatic and uninvolved skin. The correlation between predicted and clinically assigned scores was R=0.94 (RMSE=0.96), suggesting that in vivo NIR provides accurate clinical quantification of psoriatic plaques. Hence, NIR may be a practical solution to clinical severity assessment of psoriasis, providing a continuous, linear, numerical value of severity.

  1. Drug Delivery and Transport into the Central Circulation: An Example of Zero-Order In vivo Absorption of Rotigotine from a Transdermal Patch Formulation.

    PubMed

    Cawello, Willi; Braun, Marina; Andreas, Jens-Otto

    2018-01-13

    Pharmacokinetic studies using deconvolution methods and non-compartmental analysis to model clinical absorption of drugs are not well represented in the literature. The purpose of this research was (1) to define the system of equations for description of rotigotine (a dopamine receptor agonist delivered via a transdermal patch) absorption based on a pharmacokinetic model and (2) to describe the kinetics of rotigotine disposition after single and multiple dosing. The kinetics of drug disposition was evaluated based on rotigotine plasma concentration data from three phase 1 trials. In two trials, rotigotine was administered via a single patch over 24 h in healthy subjects. In a third trial, rotigotine was administered once daily over 1 month in subjects with early-stage Parkinson's disease (PD). A pharmacokinetic model utilizing deconvolution methods was developed to describe the relationship between drug release from the patch and plasma concentrations. Plasma-concentration over time profiles were modeled based on a one-compartment model with a time lag, a zero-order input (describing a constant absorption via skin into central circulation) and first-order elimination. Corresponding mathematical models for single- and multiple-dose administration were developed. After single-dose administration of rotigotine patches (using 2, 4 or 8 mg/day) in healthy subjects, a constant in vivo absorption was present after a minor time lag (2-3 h). On days 27 and 30 of the multiple-dose study in patients with PD, absorption was constant during patch-on periods and resembled zero-order kinetics. Deconvolution based on rotigotine pharmacokinetic profiles after single- or multiple-dose administration of the once-daily patch demonstrated that in vivo absorption of rotigotine showed constant input through the skin into the central circulation (resembling zero-order kinetics). Continuous absorption through the skin is a basis for stable drug exposure.

  2. Evaluation of expansile nanoparticle tumor localization and efficacy in a cancer stem cell-derived model of pancreatic peritoneal carcinomatosis

    PubMed Central

    Herrera, Victoria LM; Colby, Aaron H; Tan, Glaiza AL; Moran, Ann M; O’Brien, Michael J; Colson, Yolonda L; Ruiz-Opazo, Nelson; Grinstaff, Mark W

    2016-01-01

    Aim: To evaluate the tumor localization and efficacy pH-responsive expansile nanoparticles (eNPs) as a drug delivery system for pancreatic peritoneal carcinomatosis (PPC) modeled in nude rats. Methods & materials: A Panc-1-cancer stem cell xeno1graft model of PPC was validated in vitro and in vivo. Tumor localization was tracked via in situ imaging of fluorescent eNPs. Survival of animals treated with paclitaxel-loaded eNPs (PTX-eNPs) was evaluated in vivo. Results: The Panc-1-cancer stem cell xenograft model recapitulates significant features of PPC. Rhodamine-labeled eNPs demonstrate tumor-specific, dose- and time-dependent localization to macro- and microscopic tumors following intraperitoneal injection. PTX-eNPs are as effective as free PTX in treating established PPC; but, PTX-eNPs result in fewer side effects. Conclusion: eNPs are a promising tool for the detection and treatment of PPC. PMID:27078118

  3. Clot retraction affects the extent of ultrasound-enhanced thrombolysis in an ex vivo porcine thrombosis model

    PubMed Central

    Sutton, Jonathan T.; Ivancevich, Nikolas M.; Perrin, Stephen R.; Vela, Deborah C.; Holland, Christy K.

    2013-01-01

    Using an FDA-approved contrast agent (Definity®) and thrombolytic drug (rt-PA), we investigated ultrasound-enhanced thrombolysis in two whole-blood clot models. Porcine venous blood was collected from donor hogs and coagulated in two different materials. This method produced clots with differing compositional properties, as determined by routine scanning electron microscopy and histology. Clots were deployed in an ex vivo porcine thrombolysis model, while an intermittent ultrasound scheme previously developed to maximize stable cavitation was applied and acoustic emissions were detected. Exposure of clots to 3.15 μg/mL rt-PA promoted lysis in both clot models, compared to exposure to plasma alone. However, in the presence of rt-PA, Definity®, and ultrasound, only unretracted clots experienced significant enhancement of thrombolysis compared to treatment with rt-PA. In these clots, microscopy studies revealed loose erythrocyte aggregates, a significantly less extensive fibrin network, and a higher porosity, which may facilitate increase penetration of thrombolytics by cavitation. PMID:23453629

  4. [Pulmonary surfactants: in vivo structure and in vitro biophysical models for investigation and its perspectives].

    PubMed

    Lalchev, Z; Khristova, E; Vasiliev, Kh; Todorov, R; Ekserova, D

    2007-01-01

    The metabolism, composition, structure and functions of the alveolar surfactant (AS) are described. The most adequate biophysical models for investigation of AS are considered. The principals and possibilities of three mostly used models are described in details: Monolayers, Spinning drop method and Thin liquid films. Some of the studies of Bulgarian biophysical, physicochemical, biochemical and medical groups on the structure and mechanism of action of AS in vivo using samples of amniotic fluid (AF), animal pulmonary lavages (PL) and tracheal aspirates (TA) of newborns and adults are summarized. The role of specific surfactant proteins (SP-A, SP-B, SP-C and SP-D) on the properties and function of AS is demonstrated. The opportunities of the model investigations for application in laboratory pre- and postnatal diagnosis of the respiratory distress syndrome (RDS), as well as for the efficiency of RDS therapy during exogenous surfactant therapy with ALEC (UK), Survanta (USA), Exosurf (USA), Curosurf (Italy) u Alveofact (Germany) are considered.

  5. Towards quantitative quasi-static elastography with a gravity-induced deformation source

    NASA Astrophysics Data System (ADS)

    Griesenauer, Rebekah H.; Weis, Jared A.; Arlinghaus, Lori R.; Meszoely, Ingrid M.; Miga, Michael I.

    2017-03-01

    Biomechanical breast models have been employed for applications in image registration and analysis, breast augmentation simulation, and for surgical and biopsy guidance. Accurate applications of stress-strain relationships of tissue within the breast can improve the accuracy of biomechanical models that attempt to simulate breast movements. Reported stiffness values for adipose, glandular, and cancerous tissue types vary greatly. Variations in reported stiffness properties are mainly due to differences in testing methodologies and assumptions, measurement errors, and natural inter patient differences in tissue elasticity. Therefore, patient specific, in vivo determination of breast tissue properties is ideal for these procedural applications. Many in vivo elastography methods are not quantitative and/or do not measure material properties under deformation conditions that are representative of the procedure being simulated in the model. In this study, we developed an elasticity estimation method that is performed using deformations representative of supine therapeutic procedures. Reconstruction of material properties was performed by iteratively fitting two anatomical images before and after tissue stimulation. The method proposed is work flow friendly, quantitative, and uses a non-contact, gravity-induced deformation source. We tested this material property optimization procedure in a healthy volunteer and in simulation. In simulation, we show that the algorithm can reconstruct properties with errors below 1% for adipose and 5.6% for glandular tissue regardless of the starting stiffness values used as initial guesses. In clinical data, reconstruction errors are higher (3.6% and 24.2%) due to increased noise in the system. In a clinical context, the elastography method was shown to be promising for use in biomechanical model assisted supine procedures.

  6. Compensation of optical heterogeneity-induced artifacts in fluorescence molecular tomography: theory and in vivo validation

    NASA Astrophysics Data System (ADS)

    Mohajerani, Pouyan; Adibi, Ali; Kempner, Joshua; Yared, Wael

    2009-05-01

    We present a method for reduction of image artifacts induced by the optical heterogeneities of tissue in fluorescence molecular tomography (FMT) through identification and compensation of image regions that evidence propagation of emission light through thin or low-absorption tunnels in tissue. The light tunneled as such contributes to the emission image as spurious components that might substantially overwhelm the desirable fluorescence emanating from the targeted lesions. The proposed method makes use of the strong spatial correlation between the emission and excitation images to estimate the tunneled components and yield a residual image that mainly consists of the signal due to the desirable fluorescence. This residual image is further refined using a coincidence mask constructed for each excitation-emission image pair. The coincidence mask is essentially a map of the ``hot spots'' that occur in both excitation and emission images, as such areas are often associated with tunneled emission. In vivo studies are performed on a human colon adenocarcinoma xenograft tumor model with subcutaneous tumors and a murine breast adenocarcinoma model with aggressive tumor cell metastasis and growth in the lungs. Results demonstrate significant improvements in the reconstructions achieved by the proposed method.

  7. Model-based ultrasound temperature visualization during and following HIFU exposure.

    PubMed

    Ye, Guoliang; Smith, Penny Probert; Noble, J Alison

    2010-02-01

    This paper describes the application of signal processing techniques to improve the robustness of ultrasound feedback for displaying changes in temperature distribution in treatment using high-intensity focused ultrasound (HIFU), especially at the low signal-to-noise ratios that might be expected in in vivo abdominal treatment. Temperature estimation is based on the local displacements in ultrasound images taken during HIFU treatment, and a method to improve robustness to outliers is introduced. The main contribution of the paper is in the application of a Kalman filter, a statistical signal processing technique, which uses a simple analytical temperature model of heat dispersion to improve the temperature estimation from the ultrasound measurements during and after HIFU exposure. To reduce the sensitivity of the method to previous assumptions on the material homogeneity and signal-to-noise ratio, an adaptive form is introduced. The method is illustrated using data from HIFU exposure of ex vivo bovine liver. A particular advantage of the stability it introduces is that the temperature can be visualized not only in the intervals between HIFU exposure but also, for some configurations, during the exposure itself. 2010 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  8. Multicolor bleach-rate imaging enlightens in vivo sterol transport

    PubMed Central

    Sage, Daniel

    2010-01-01

    Elucidation of in vivo cholesterol transport and its aberrations in cardiovascular diseases requires suitable model organisms and the development of appropriate monitoring technology. We recently presented a new approach to visualize transport of the intrinsically fluorescent sterol, dehydroergosterol (DHE) in the genetically tractable model organism Caenorhabditis elegans (C. elegans). DHE is structurally very similar to cholesterol and ergosterol, two sterols used by the sterol-auxotroph nematode. We developed a new computational method measuring fluorophore bleaching kinetics at every pixel position, which can be used as a fingerprint to distinguish rapidly bleaching DHE from slowly bleaching autofluorescence in the animals. Here, we introduce multicolor bleach-rate sterol imaging. By this method, we demonstrate that some DHE is targeted to a population of basolateral recycling endosomes (RE) labelled with GFP-tagged RME-1 (GFP-RME-1) in the intestine of both, wild-type nematodes and mutant animals lacking intestinal gut granules (glo1-mutants). DHE-enriched intestinal organelles of glo1-mutants were decorated with GFPrme8, a marker for early endosomes. No co-localization was found with a lysosomal marker, GFP-LMP1. Our new methods hold great promise for further studies on endosomal sterol transport in C. elegans. PMID:20798830

  9. The baric probe: a novel long-term implantable intracranial pressure monitor with ultrasound-based interrogation.

    PubMed

    Limbrick, David D; Lake, Stephen; Talcott, Michael; Alexander, Benjamin; Wight, Samuel; Willie, Jon T; Richard, William D; Genin, Guy M; Leuthardt, Eric C

    2012-12-01

    Prompt diagnosis of shunt malfunction is critical in preventing neurological morbidity and death in individuals with hydrocephalus; however, diagnostic methods for this condition remain limited. For several decades, investigators have sought a long-term, implantable intracranial pressure (ICP) monitor to assist in the diagnosis of shunt malfunction, but efforts have been impeded by device complexity, marked measurement drift, and limited instrumentation lifespan. In the current report, the authors introduce an entirely novel, simple, compressible gas design that addresses each of these problems. The device described herein, termed the "baric probe," consists of a subdural fluid bladder and multichannel indicator that monitors the position of an air-fluid interface (AFI). A handheld ultrasound probe is used to interrogate the baric probe in vivo, permitting noninvasive ICP determination. To assess the function of device prototypes, ex vivo experiments were conducted using a water column, and short- and long-term in vivo experiments were performed using a porcine model with concurrent measurements of ICP via a fiberoptic monitor. Following a toe region of approximately 2 cm H(2)O, the baric probe's AFI demonstrated a predictable linear relationship to ICP in both ex vivo and in vivo models. After a 2-week implantation of the device, this linear relationship remained robust and reproducible. Further, changes in ICP were observed with the baric probe, on average, 3 seconds in advance of the fiberoptic ICP monitor reading. The authors demonstrate "proof-of-concept" and feasibility for the baric probe, a long-term implantable ICP monitor designed to facilitate the prompt and accurate diagnosis of shunt malfunction. The baric probe showed a consistent linear relationship between ICP and the device's AFI in ex vivo and short- and long-term in vivo models. With a low per-unit cost, a reduced need for radiography or CT, and an indicator that can be read with a handheld ultrasound probe that interfaces with any smart phone, the baric probe promises to simplify the care of patients with shunt-treated hydrocephalus throughout both the developed and the developing world.

  10. In Vivo Fluorescence Resonance Energy Transfer Imaging for Targeted Anti-Cancer Drug Delivery Kinetics

    NASA Astrophysics Data System (ADS)

    Webb, Kevin; Gaind, Vaibhav; Tsai, Hsiaorho; Bentz, Brian; Chelvam, Venkatesh; Low, Philip

    2012-02-01

    We describe an approach for the evaluation of targeted anti-cancer drug delivery in vivo. The method emulates the drug release and activation process through acceptor release from a targeted donor-acceptor pair that exhibits fluorescence resonance energy transfer (FRET). In this case, folate targeting of the cancer cells is used - 40 % of all human cancers, including ovarian, lung, breast, kidney, brain and colon cancer, over-express folate receptors. We demonstrate the reconstruction of the spatially-dependent FRET parameters in a mouse model and in tissue phantoms. The FRET parameterization is incorporated into a source for a diffusion equation model for photon transport in tissue, in a variant of optical diffusion tomography (ODT) called FRET-ODT. In addition to the spatially-dependent tissue parameters in the diffusion model (absorption and diffusion coefficients), the FRET parameters (donor-acceptor distance and yield) are imaged as a function of position. Modulated light measurements are made with various laser excitation positions and a gated camera. More generally, our method provides a new vehicle for studying disease at the molecular level by imaging FRET parameters in deep tissue, and allows the nanometer FRET ruler to be utilized in deep tissue.

  11. Multi-Component Molecular-Level Body Composition Reference Methods: Evolving Concepts and Future Directions

    PubMed Central

    Heymsfield, Steven B.; Ebbeling, Cara B.; Zheng, Jolene; Pietrobelli, Angelo; Strauss, Boyd J.; Silva, Analiza M.; Ludwig, David S.

    2015-01-01

    Excess adiposity is the main phenotypic feature that defines human obesity and that plays a pathophysiological role in most chronic diseases. Measuring the amount of fat mass present is thus a central aspect of studying obesity at the individual and population levels. Nevertheless, a consensus is lacking among investigators on a single accepted “reference” approach for quantifying fat mass in vivo. While the research community generally relies on the multicomponent body-volume class of “reference” models for quantifying fat mass, no definable guide discerns among different applied equations for partitioning the four (fat, water, protein, and mineral mass) or more quantified components, standardizes “adjustment” or measurement system approaches for model-required labeled water dilution volumes and bone mineral mass estimates, or firmly establishes the body temperature at which model physical properties are assumed. The resulting differing reference strategies for quantifying body composition in vivo leads to small but under some circumstances important differences in the amount of measured body fat. Recent technological advances highlight opportunities to expand model applications to new subject groups and measured components such as total body protein. The current report reviews the historical evolution of multicomponent body volume-based methods in the context of prevailing uncertainties and future potential. PMID:25645009

  12. A Novel Two-Step Hierarchial Quantitative Structure-Activity ...

    EPA Pesticide Factsheets

    Background: Accurate prediction of in vivo toxicity from in vitro testing is a challenging problem. Large public–private consortia have been formed with the goal of improving chemical safety assessment by the means of high-throughput screening. Methods and results: A database containing experimental cytotoxicity values for in vitro half-maximal inhibitory concentration (IC50) and in vivo rodent median lethal dose (LD50) for more than 300 chemicals was compiled by Zentralstelle zur Erfassung und Bewertung von Ersatz- und Ergaenzungsmethoden zum Tierversuch (ZEBET ; National Center for Documentation and Evaluation of Alternative Methods to Animal Experiments) . The application of conventional quantitative structure–activity relationship (QSAR) modeling approaches to predict mouse or rat acute LD50 values from chemical descriptors of ZEBET compounds yielded no statistically significant models. The analysis of these data showed no significant correlation between IC50 and LD50. However, a linear IC50 versus LD50 correlation could be established for a fraction of compounds. To capitalize on this observation, we developed a novel two-step modeling approach as follows. First, all chemicals are partitioned into two groups based on the relationship between IC50 and LD50 values: One group comprises compounds with linear IC50 versus LD50 relationships, and another group comprises the remaining compounds. Second, we built conventional binary classification QSAR models t

  13. History, ethics, advantages and limitations of experimental models for hepatic ablation.

    PubMed

    Ong, Seok Ling; Gravante, Gianpiero; Metcalfe, Matthew S; Dennison, Ashley R

    2013-01-14

    Numerous techniques developed in medicine require careful evaluation to determine their indications, limitations and potential side effects prior to their clinical use. At present this generally involves the use of animal models which is undesirable from an ethical standpoint, requires complex and time-consuming authorization, and is very expensive. This process is exemplified in the development of hepatic ablation techniques, starting experiments on explanted livers and progressing to safety and efficacy studies in living animals prior to clinical studies. The two main approaches used are ex vivo isolated non-perfused liver models and in vivo animal models. Ex vivo non perfused models are less expensive, easier to obtain but not suitable to study the heat sink effect or experiments requiring several hours. In vivo animal models closely resemble clinical subjects but often are expensive and have small sample sizes due to ethical guidelines. Isolated perfused ex vivo liver models have been used to study drug toxicity, liver failure, organ transplantation and hepatic ablation and combine advantages of both previous models.

  14. BRI2 (ITM2b) Inhibits Aβ Deposition in Vivo

    PubMed Central

    Kim, Jungsu; Miller, Victor M.; Levites, Yona; West, Karen Jansen; Zwizinski, Craig W.; Moore, Brenda D.; Troendle, Fredrick J.; Bann, Maralyssa; Verbeeck, Christophe; Price, Robert W.; Smithson, Lisa; Sonoda, Leilani; Wagg, Kayleigh; Rangachari, Vijayaraghavan; Zou, Fanggeng; Younkin, Steven G.; Graff-Radford, Neill; Dickson, Dennis; Rosenberry, Terrone; Golde, Todd E.

    2008-01-01

    Analyses of the biologic effects of mutations in the BRI2 (ITM2b) and the amyloid β precursor protein (APP) genes support the hypothesis that cerebral accumulation of amyloidogenic peptides in familial British and familial Danish dementias and Alzheimer’s disease (AD) is associated with neurodegeneration. We have used somatic brain transgenic technology to express the BRI2 and BRI2-Aβ1-40 transgenes in amyloid β protein precursor (APP) mouse models. Expression of BRI2-Aβ1-40 mimics the suppressive effect previously observed using conventional transgenic methods, further validating the somatic brain transgenic methodology. Unexpectedly, we also find that expression of wild type human BRI2 reduces cerebral Aβ deposition in an AD mouse model. Additional data indicate that the 23 amino acid peptide, Bri23, released from BRI2 by normal processing is present in human cerebrospinal fluid (CSF), inhibits Aβ aggregation in vitro, and mediates its anti-amyloidogenic effect in vivo. These studies demonstrate that BRI2 is a novel mediator of Aβ deposition in vivo. PMID:18524908

  15. WE-EF-210-06: Ultrasound 2D Strain Measurement of Radiation-Induced Toxicity: Phantom and Ex Vivo Experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, T; Torres, M; Rossi, P

    Purpose: Radiation-induced fibrosis is a common long-term complication affecting many patients following cancer radiotherapy. Standard clinical assessment of subcutaneous fibrosis is subjective and often limited to visual inspection and palpation. Ultrasound strain imaging describes the compressibility (elasticity) of biological tissues. This study’s purpose is to develop a quantitative ultrasound strain imaging that can consistently and accurately characterize radiation-induce fibrosis. Methods: In this study, we propose a 2D strain imaging method based on deformable image registration. A combined affine and B-spline transformation model is used to calculate the displacement of tissue between pre-stress and post-stress B-mode image sequences. The 2D displacementmore » is estimated through a hybrid image similarity measure metric, which is a combination of the normalized mutual information (NMI) and normalized sum-of-squared-differences (NSSD). And 2D strain is obtained from the gradient of the local displacement. We conducted phantom experiments under various compressions and compared the performance of our proposed method with the standard cross-correlation (CC)- based method using the signal-to-noise (SNR) and contrast-to-noise (CNS) ratios. In addition, we conducted ex-vivo beef muscle experiment to further validate the proposed method. Results: For phantom study, the SNR and CNS values of the proposed method were significantly higher than those calculated from the CC-based method under different strains. The SNR and CNR increased by a factor of 1.9 and 2.7 comparing to the CC-based method. For the ex-vivo experiment, the CC-based method failed to work due to large deformation (6.7%), while our proposed method could accurately detect the stiffness change. Conclusion: We have developed a 2D strain imaging technique based on the deformable image registration, validated its accuracy and feasibility with phantom and ex-vivo data. This 2D ultrasound strain imaging technology may be valuable as physicians try to eliminate radiation-induce fibrosis and improve the therapeutic ratio of cancer radiotherapy. This research is supported in part by DOD PCRP Award W81XWH-13-1-0269, and National Cancer Institute (NCI) Grant CA114313.« less

  16. The biological effects of quadripolar radiofrequency sequential application: a human experimental study.

    PubMed

    Nicoletti, Giovanni; Cornaglia, Antonia Icaro; Faga, Angela; Scevola, Silvia

    2014-10-01

    An experimental study was conducted to assess the effectiveness and safety of an innovative quadripolar variable electrode configuration radiofrequency device with objective measurements in an ex vivo and in vivo human experimental model. Nonablative radiofrequency applications are well-established anti-ageing procedures for cosmetic skin tightening. The study was performed in two steps: ex vivo and in vivo assessments. In the ex vivo assessments the radiofrequency applications were performed on human full-thickness skin and subcutaneous tissue specimens harvested during surgery for body contouring. In the in vivo assessments the applications were performed on two volunteer patients scheduled for body contouring surgery at the end of the study. The assessment methods were: clinical examination and medical photography, temperature measurement with thermal imaging scan, and light microscopy histological examination. The ex vivo assessments allowed for identification of the effective safety range for human application. The in vivo assessments allowed for demonstration of the biological effects of sequential radiofrequency applications. After a course of radiofrequency applications, the collagen fibers underwent an immediate heat-induced rearrangement and were partially denaturated and progressively metabolized by the macrophages. An overall thickening and spatial rearrangement was appreciated both in the collagen and elastic fibers, the latter displaying a juvenile reticular pattern. A late onset in the macrophage activation after sequential radiofrequency applications was appreciated. Our data confirm the effectiveness of sequential radiofrequency applications in obtaining attenuation of the skin wrinkles by an overall skin tightening.

  17. Using Bayesian analysis in repeated preclinical in vivo studies for a more effective use of animals.

    PubMed

    Walley, Rosalind; Sherington, John; Rastrick, Joe; Detrait, Eric; Hanon, Etienne; Watt, Gillian

    2016-05-01

    Whilst innovative Bayesian approaches are increasingly used in clinical studies, in the preclinical area Bayesian methods appear to be rarely used in the reporting of pharmacology data. This is particularly surprising in the context of regularly repeated in vivo studies where there is a considerable amount of data from historical control groups, which has potential value. This paper describes our experience with introducing Bayesian analysis for such studies using a Bayesian meta-analytic predictive approach. This leads naturally either to an informative prior for a control group as part of a full Bayesian analysis of the next study or using a predictive distribution to replace a control group entirely. We use quality control charts to illustrate study-to-study variation to the scientists and describe informative priors in terms of their approximate effective numbers of animals. We describe two case studies of animal models: the lipopolysaccharide-induced cytokine release model used in inflammation and the novel object recognition model used to screen cognitive enhancers, both of which show the advantage of a Bayesian approach over the standard frequentist analysis. We conclude that using Bayesian methods in stable repeated in vivo studies can result in a more effective use of animals, either by reducing the total number of animals used or by increasing the precision of key treatment differences. This will lead to clearer results and supports the "3Rs initiative" to Refine, Reduce and Replace animals in research. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  18. Mapping of Cardiac Electrical Activation with Electromechanical Wave Imaging: An in silico-in vivo Reciprocity Study

    PubMed Central

    Provost, Jean; Gurev, Viatcheslav; Trayanova, Natalia; Konofagou, Elisa E.

    2011-01-01

    Background Electromechanical Wave Imaging (EWI) is an entirely non-invasive, ultrasound-based imaging method capable of mapping the electromechanical activation sequence of the ventricles in vivo. Given the broad accessibility of ultrasound scanners in the clinic, the application of EWI could constitute a flexible surrogate for the 3D electrical activation. Objective The purpose of this report is to reproduce the electromechanical wave (EW) using an anatomically-realistic electromechanical model, and establish the capability of EWI to map the electrical activation sequence in vivo when pacing from different locations. Methods EWI was performed in one canine during pacing from three different sites. A high-resolution dynamic model of coupled cardiac electromechanics of the canine heart was used to predict the experimentally recorded electromechanical wave. The simulated 3D electrical activation sequence was then compared with the experimental EW. Results The electrical activation sequence and the EW were highly correlated for all pacing sites. The relationship between the electrical activation and the EW onset was found to be linear with a slope of 1.01 to 1.17 for different pacing schemes and imaging angles. Conclusions The accurate reproduction of the EW in simulations indicates that the model framework is capable of accurately representing the cardiac electromechanics and thus testing new hypotheses. The one-to-one correspondence between the electrical activation sequence and the EW indicates that EWI could be used to map the cardiac electrical activity. This opens the door for further exploration of the technique in assisting in the early detection, diagnosis and treatment monitoring of rhythm dysfunction. PMID:21185403

  19. Bipolar radiofrequency ablation with 2 × 2 electrodes as a building block for matrix radiofrequency ablation: Ex vivo liver experiments and finite element method modelling.

    PubMed

    Mulier, Stefaan; Jiang, Yansheng; Jamart, Jacques; Wang, Chong; Feng, Yuanbo; Marchal, Guy; Michel, Luc; Ni, Yicheng

    2015-01-01

    Size and geometry of the ablation zone obtained by currently available radiofrequency (RF) electrodes is highly variable. Reliability might be improved by matrix radiofrequency ablation (MRFA), in which the whole tumour volume is contained within a cage of x × y parallel electrodes. The aim of this study was to optimise the smallest building block for matrix radiofrequency ablation: a recently developed bipolar 2 × 2 electrode system. In ex vivo bovine liver, the parameters of the experimental set-up were changed one by one. In a second step, a finite element method (FEM) modelling of the experiment was performed to better understand the experimental findings. The optimal power to obtain complete ablation in the shortest time was 50-60 W. Performing an ablation until impedance rise was superior to ablation for a fixed duration. Increasing electrode diameter improved completeness of ablation due to lower temperature along the electrodes. A chessboard pattern of electrode polarity was inferior to a row pattern due to an electric field void in between the electrodes. Variability of ablation size was limited. The FEM correctly simulated and explained the findings in ex vivo liver. These experiments and FEM modelling allowed a better insight in the factors influencing the ablation zone in a bipolar 2 × 2 electrode RF system. With optimal parameters, complete ablation was obtained quickly and with limited variability. This knowledge will be useful to build a larger system with x × y electrodes for MRFA.

  20. Kalman Filtered Bio Heat Transfer Model Based Self-adaptive Hybrid Magnetic Resonance Thermometry.

    PubMed

    Zhang, Yuxin; Chen, Shuo; Deng, Kexin; Chen, Bingyao; Wei, Xing; Yang, Jiafei; Wang, Shi; Ying, Kui

    2017-01-01

    To develop a self-adaptive and fast thermometry method by combining the original hybrid magnetic resonance thermometry method and the bio heat transfer equation (BHTE) model. The proposed Kalman filtered Bio Heat Transfer Model Based Self-adaptive Hybrid Magnetic Resonance Thermometry, abbreviated as KalBHT hybrid method, introduced the BHTE model to synthesize a window on the regularization term of the hybrid algorithm, which leads to a self-adaptive regularization both spatially and temporally with change of temperature. Further, to decrease the sensitivity to accuracy of the BHTE model, Kalman filter is utilized to update the window at each iteration time. To investigate the effect of the proposed model, computer heating simulation, phantom microwave heating experiment and dynamic in-vivo model validation of liver and thoracic tumor were conducted in this study. The heating simulation indicates that the KalBHT hybrid algorithm achieves more accurate results without adjusting λ to a proper value in comparison to the hybrid algorithm. The results of the phantom heating experiment illustrate that the proposed model is able to follow temperature changes in the presence of motion and the temperature estimated also shows less noise in the background and surrounding the hot spot. The dynamic in-vivo model validation with heating simulation demonstrates that the proposed model has a higher convergence rate, more robustness to susceptibility problem surrounding the hot spot and more accuracy of temperature estimation. In the healthy liver experiment with heating simulation, the RMSE of the hot spot of the proposed model is reduced to about 50% compared to the RMSE of the original hybrid model and the convergence time becomes only about one fifth of the hybrid model. The proposed model is able to improve the accuracy of the original hybrid algorithm and accelerate the convergence rate of MR temperature estimation.

  1. Transcriptional Responses Reveal Similarities Between Preclinical Rat Liver Testing Systems.

    PubMed

    Liu, Zhichao; Delavan, Brian; Roberts, Ruth; Tong, Weida

    2018-01-01

    Toxicogenomics (TGx) is an important tool to gain an enhanced understanding of toxicity at the molecular level. Previously, we developed a pair ranking (PRank) method to assess in vitro to in vivo extrapolation (IVIVE) using toxicogenomic datasets from the Open Toxicogenomics Project-Genomics Assisted Toxicity Evaluation System (TG-GATEs) database. With this method, we investiagted three important questions that were not addressed in our previous study: (1) is a 1-day in vivo short-term assay able to replace the 28-day standard and expensive toxicological assay? (2) are some biological processes more conservative across different preclinical testing systems than others? and (3) do these preclinical testing systems have the similar resolution in differentiating drugs by their therapeutic uses? For question 1, a high similarity was noted (PRank score = 0.90), indicating the potential utility of shorter term in vivo studies to predict outcome in longer term and more expensive in vivo model systems. There was a moderate similarity between rat primary hepatocytes and in vivo repeat-dose studies (PRank score = 0.71) but a low similarity (PRank score = 0.56) between rat primary hepatocytes and in vivo single dose studies. To address question 2, we limited the analysis to gene sets relevant to specific toxicogenomic pathways and we found that pathways such as lipid metabolism were consistently over-represented in all three assay systems. For question 3, all three preclinical assay systems could distinguish compounds from different therapeutic categories. This suggests that any noted differences in assay systems was biological process-dependent and furthermore that all three systems have utility in assessing drug responses within a certain drug class. In conclusion, this comparison of three commonly used rat TGx systems provides useful information in utility and application of TGx assays.

  2. Optical Coherence Tomography Based Estimates of Crystalline Lens Volume, Equatorial Diameter, and Plane Position.

    PubMed

    Martinez-Enriquez, Eduardo; Sun, Mengchan; Velasco-Ocana, Miriam; Birkenfeld, Judith; Pérez-Merino, Pablo; Marcos, Susana

    2016-07-01

    Measurement of crystalline lens geometry in vivo is critical to optimize performance of state-of-the-art cataract surgery. We used custom-developed quantitative anterior segment optical coherence tomography (OCT) and developed dedicated algorithms to estimate lens volume (VOL), equatorial diameter (DIA), and equatorial plane position (EPP). The method was validated ex vivo in 27 human donor (19-71 years of age) lenses, which were imaged in three-dimensions by OCT. In vivo conditions were simulated assuming that only the information within a given pupil size (PS) was available. A parametric model was used to estimate the whole lens shape from PS-limited data. The accuracy of the estimated lens VOL, DIA, and EPP was evaluated by comparing estimates from the whole lens data and PS-limited data ex vivo. The method was demonstrated in vivo using 2 young eyes during accommodation and 2 cataract eyes. Crystalline lens VOL was estimated within 96% accuracy (average estimation error across lenses ± standard deviation: 9.30 ± 7.49 mm3). Average estimation errors in EPP were below 40 ± 32 μm, and below 0.26 ± 0.22 mm in DIA. Changes in lens VOL with accommodation were not statistically significant (2-way ANOVA, P = 0.35). In young eyes, DIA decreased and EPP increased statistically significantly with accommodation (P < 0.001) by 0.14 mm and 0.13 mm, respectively, on average across subjects. In cataract eyes, VOL = 205.5 mm3, DIA = 9.57 mm, and EPP = 2.15 mm on average. Quantitative OCT with dedicated image processing algorithms allows estimation of human crystalline lens volume, diameter, and equatorial lens position, as validated from ex vivo measurements, where entire lens images are available.

  3. Measuring In Vivo Free Radical Production by the Outer Retina

    PubMed Central

    Berkowitz, Bruce A.; Bredell, Bryce X.; Davis, Christopher; Samardzija, Marijana; Grimm, Christian; Roberts, Robin

    2015-01-01

    Purpose Excessive and continuously produced free radicals in the outer retina are implicated in retinal aging and the pathogenesis of sight-threatening retinopathies, yet measuring outer retinal oxidative stress in vivo remains a challenge. Here, we test the hypothesis that continuously produced paramagnetic free radicals from the outer retina can be measured in vivo using high-resolution (22-μm axial resolution) 1/T1magnetic resonance imaging (MRI) without and with a confirmatory quench (quench-assisted MRI). Methods Low-dose sodium iodate–treated and diabetic C57Bl6/J mice (and their controls), and rod-dominated (129S6) or cone-only R91W;Nrl−/− mice were studied. In dark-adapted groups, 1/T1 was mapped transretinally in vivo without or with (1) the antioxidant combination of methylene blue (MB) and α-lipoic acid (LPA), or (2) light exposure; in subgroups, retinal superoxide production was measured ex vivo (lucigenin). Results In the sodium iodate model, retinal superoxide production and outer retina-specific 1/T1 values were both significantly greater than normal and corrected to baseline with MB+LPA therapy. Nondiabetic mice at two ages and 1.2-month diabetic mice (before the appearance of oxidative stress) had similar transretinal 1/T1 profiles. By 2.3 months of diabetes, only outer retinal 1/T1 values were significantly greater than normal and were corrected to baseline with MB+LPA therapy. In mice with healthy photoreceptors, a light quench caused 1/T1 of rods, but not cones, to significantly decrease from their values in the dark. Conclusions Quench-assisted MRI is a feasible method for noninvasively measuring normal and pathologic production of free radicals in photoreceptors/RPE in vivo. PMID:26670830

  4. In vivo antimicrobial activity of silver nanoparticles produced via a green chemistry synthesis using Acacia rigidula as a reducing and capping agent

    PubMed Central

    Escárcega-González, Carlos Enrique; Garza-Cervantes, JA; Vázquez-Rodríguez, A; Montelongo-Peralta, Liliana Zulem; Treviño-González, MT; Díaz Barriga Castro, E; Saucedo-Salazar, EM; Chávez Morales, RM; Regalado Soto, DI; Treviño González, FM; Carrazco Rosales, JL; Cruz, Rocío Villalobos; Morones-Ramírez, José Rubén

    2018-01-01

    Introduction One of the main issues in the medical field and clinical practice is the development of novel and effective treatments against infections caused by antibiotic-resistant bacteria. One avenue that has been approached to develop effective antimicrobials is the use of silver nanoparticles (Ag-NPs), since they have been found to exhibit an efficient and wide spectrum of antimicrobial properties. Among the main drawbacks of using Ag-NPs are their potential cytotoxicity against eukaryotic cells and the latent environmental toxicity of their synthesis methods. Therefore, diverse green synthesis methods, which involve the use of environmentally friendly plant extracts as reductive and capping agents, have become attractive to synthesize Ag-NPs that exhibit antimicrobial effects against resistant bacteria at concentrations below toxicity thresholds for eukaryotic cells. Purpose In this study, we report a green one-pot synthesis method that uses Acacia rigidula extract as a reducing and capping agent, to produce Ag-NPs with applications as therapeutic agents to treat infections in vivo. Materials and methods The Ag-NPs were characterized using transmission electron microscopy (TEM), high-resolution TEM, selected area electron diffraction, energy-dispersive spectroscopy, ultraviolet–visible, and Fourier transform infrared. Results We show that Ag-NPs are spherical with a narrow size distribution. The Ag-NPs show antimicrobial activities in vitro against Gram-negative (Escherichia coli, Pseudomonas aeruginosa, and a clinical multidrug-resistant strain of P. aeruginosa) and Gram-positive (Bacillus subtilis) bacteria. Moreover, antimicrobial effects of the Ag-NPs, against a resistant P. aeruginosa clinical strain, were tested in a murine skin infection model. The results demonstrate that the Ag-NPs reported in this work are capable of eradicating pathogenic resistant bacteria in an infection in vivo. In addition, skin, liver, and kidney damage profiles were monitored in the murine infection model, and the results demonstrate that Ag-NPs can be used safely as therapeutic agents in animal models. Conclusion Together, these results suggest the potential use of Ag-NPs, synthesized by green chemistry methods, as therapeutic agents against infections caused by resistant and nonresistant strains. PMID:29713166

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, M; Finlay, J; Zhu, T

    Purpose: Photosensitizer concentration during photodynamic therapy (PDT) is an important parameter for accurate dosimetry. Fluorescence signal can be used as a measure of photosensitizer concentration. Two methods of data acquisition were compared to an ex vivo study both for in vivo and phantom models. Methods: Fluorescence signal of commonly used photosensitizer benzoporphyrin derivative monoacid ring A (BPD) was obtained in phantoms and mouse tumors using an excitation light of 405 nm. Interstitial fluorescence signal was obtained using a side-cut fiber inserted into the tumor tissue of interest. Using a previously developed multi-fiber probe, tumor surface fluorescence measurements were also collected.more » Signals were calibrated according to optical phantoms with known sensitizer fluorescence. Optical properties for each sample were determined and the influence of different absorption and scattering properties on the fluorescence signals was investigated. Using single value decomposition of the spectra, the sensitizer concentration was determined using the two different measurement geometries. An ex vivo analysis was also performed for tumor samples to determine the sensitizer concentration. Results: The two fluorescence signals obtained from the surface multi-fiber probe and the interstitial measurements were compared and were corresponding for both phantoms and mouse models. The values obtained were comparable to the ex vivo measurements as well. Despite the difference in geometry, the surface probe measurements can still be used as a metric for determining the presence of sensitizer in small volume tumors. Conclusion: The multi-fiber contact probe can be used as a tool to measure fluorescence at the surface of the treatment area for PDT and predict sensitizer concentration throughout the tumor. This is advantageous in that the measurement does not damage any tissue. Future work will include investigating the dependence of these results on intratumor sensitizer distribution.« less

  6. Acellular vascular matrix grafts from human placenta chorion: Impact of ECM preservation on graft characteristics, protein composition and in vivo performance.

    PubMed

    Schneider, Karl H; Enayati, Marjan; Grasl, Christian; Walter, Ingrid; Budinsky, Lubos; Zebic, Gabriel; Kaun, Christoph; Wagner, Anja; Kratochwill, Klaus; Redl, Heinz; Teuschl, Andreas H; Podesser, Bruno K; Bergmeister, Helga

    2018-05-29

    Small diameter vascular grafts from human placenta, decellularized with either Triton X-100 (Triton) or SDS and crosslinked with heparin were constructed and characterized. Graft biochemical properties, residual DNA, and protein composition were evaluated to compare the effect of the two detergents on graft matrix composition and structural alterations. Biocompatibility was tested in vitro by culturing the grafts with primary human macrophages and in vivo by subcutaneous implantation of graft conduits (n = 7 per group) into the flanks of nude rats. Subsequently, graft performance was evaluated using an aortic implantation model in Sprague Dawley rats (one month, n = 14). In situ graft imaging was performed using MRI angiography. Retrieved specimens were analyzed by electromyography, scanning electron microscopy, histology and immunohistochemistry to evaluate cell migration and the degree of functional tissue remodeling. Both decellularization methods resulted in grafts of excellent biocompatibility in vitro and in vivo, with low immunogenic potential. Proteomic data revealed removal of cytoplasmic proteins with relative enrichment of ECM proteins in decelluarized specimens of both groups. Noteworthy, LC-Mass Spectrometry analysis revealed that 16 proteins were exclusively preserved in Triton decellularized specimens in comparison to SDS-treated specimens. Aortic grafts showed high patency rates, no signs of thrombus formation, aneurysms or rupture. Conduits of both groups revealed tissue-specific cell migration indicative of functional remodeling. This study strongly suggests that decellularized allogenic grafts from the human placenta have the potential to be used as vascular replacement materials. Both detergents produced grafts with low residual immunogenicity and appropriate mechanical properties. Observed differences in graft characteristics due to preservation method had no impact on successful in vivo performance in the rodent model. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. In vivo evaluation method of the effect of nattokinase on carrageenan-induced tail thrombosis in a rat model.

    PubMed

    Kamiya, Seitaro; Hagimori, Masayori; Ogasawara, Masayoshi; Arakawa, Masayuki

    2010-01-01

    Thrombosis is characterized by congenital and acquired procatarxis. Nattokinase inhibits thrombus formation in vitro. However, in vivo evaluation of the therapeutic efficacy of nattokinase against thrombosis remains to be conducted. Subcutaneous nattokinase injections of 1 or 2 mg/ml were administered to the tails of rats. Subsequently, κ-carrageenan was intravenously administered to the tails at 12 h after nattokinase injections. The mean length of the infarcted regions in the tails of rats was significantly shorter in rats administered 2 mg/ml of nattokinase than those in control rats. Nattokinase exhibited significant prophylactic antithrombotic effects. Previously, the in vitro efficacy of nattokinase against thrombosis had been reported; now our study has revealed the in vivo efficacy of nattokinase against thrombosis. Copyright © 2010 S. Karger AG, Basel.

  8. Reverse total shoulder arthroplasty: research models

    PubMed Central

    PETRILLO, STEFANO; LONGO, UMILE GIUSEPPE; GULOTTA, LAWRENCE V.; BERTON, ALESSANDRA; KONTAXIS, ANDREAS; WRIGHT, TIMOTHY; DENARO, VINCENZO

    2016-01-01

    Purpose the past decade has seen a considerable increase in the use of research models to study reverse total shoulder arthroplasty (RTSA). Nevertheless, none of these models has been shown to completely reflect real in vivo conditions. Methods we performed a systematic review of the literature matching the following key words: “reverse total shoulder arthroplasty” or “reverse total shoulder replacement” or “reverse total shoulder prosthesis” and “research models” or “biomechanical models” or “physical simulators” or “virtual simulators”. The following databases were screened: Medline, Google Scholar, EMBASE, CINAHIL and Ovid. We identified and included all articles reporting research models of any kind, such as physical or virtual simulators, in which RTSA and the glenohumeral joint were reproduced. Results computer models and cadaveric models are the most commonly used, and they were shown to be reliable in simulating in vivo conditions. Bone substitute models have been used in a few studies. Mechanical testing machines provided useful information on stability factors in RTSA. Conclusion because of the limitations of each individual model, additional research is required to develop a research model of RTSA that may reduce the limitations of those presently available, and increase the reproducibility of this technique in the clinical setting. PMID:28217660

  9. Ex vivo blood vessel bioreactor for analysis of the biodegradation of magnesium stent models with and without vessel wall integration

    PubMed Central

    Wang, Juan; Liu, Lumei; Wu, Yifan; Maitz, Manfred F.; Wang, Zhihong; Koo, Youngmi; Zhao, Ansha; Sankar, Jagannathan; Kong, Deling; Huang, Nan; Yun, Yeoheung

    2017-01-01

    Current in vitro models fail in predicting the degradation rate and mode of magnesium (Mg) stents in vivo. To overcome this, the microenvironment of the stent is simulated here in an ex vivo bioreactor with porcine aorta and circulating medium, and compared with standard static in vitro immersion and with in vivo rat aorta models. In ex vivo and in vivo conditions, pure Mg wires were exposed to the aortic lumen and inserted into the aortic wall to mimic early- and long-term implantation, respectively. Results showed that: 1) Degradation rates of Mg were similar for all the fluid diffusion conditions (in vitro static, aortic wall ex vivo and in vivo); however, Mg degradation under flow condition (i.e. in the lumen) in vivo was slower than ex vivo; 2) The corrosion mode in the samples can be mainly described as localized (in vitro), mixed localized and uniform (ex vivo), and uniform (in vivo); 3) Abundant degradation products (MgO/Mg(OH)2 and Ca/P) with gas bubbles accumulated around the localized degradation regions ex vivo, but a uniform and thin degradation product layer was found in vivo. It is concluded that the ex vivo vascular bioreactor provides an improved test setting for magnesium degradation between static immersion and animal experiments and highlights its promising role in bridging degradation behavior and biological response for vascular stent research. PMID:28013101

  10. Detection of microvasculature alterations by synchrotron radiation in murine with delayed jellyfish envenomation syndrome.

    PubMed

    Wang, Beilei; Zhang, Bo; Huo, Hua; Wang, Tao; Wang, Qianqian; Wu, Yuanlin; Xiao, Liang; Ren, Yuqi; Zhang, Liming

    2014-04-01

    Using the tentacle extract (TE) from the jellyfish Cyanea capillata, we have previously established a delayed jellyfish envenomation syndrome (DJES) model, which is meaningful for clinical interventions against jellyfish stings. However, the mechanism of DJES still remains unclear. Thus, this study aimed to explore its potential mechanism by detecting TE-induced microvasculature alterations in vivo and ex vivo. Using a third-generation synchrotron radiation facility, we, for the first time, directly observed the blood vessel alterations induced by jellyfish venom in vivo and ex vivo. Firstly, microvasculature imaging of whole-body mouse in vivo indicated that the small blood vessel branches in the liver and kidney in the TE-treated group, seemed much thinner than those in the control group. Secondly, 3D imaging of kidney ex vivo showed that the kidneys in the TE-treated group had incomplete vascular trees where distal vessel branches were partly missing and disorderly disturbed. Finally, histopathological analysis found that obvious morphological changes, especially hemorrhagic effects, were also present in the TE-treated kidney. Thus, TE-induced microvasculature changes might be one of the important mechanisms of multiple organ dysfunctions in DJES. In addition, the methods we employed here will probably facilitate further studies on developing effective intervention strategies against DJES. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Determining the Depth of Injury in Bioengineered Tissue Models of Cornea and Conjunctiva for the Prediction of All Three Ocular GHS Categories

    PubMed Central

    Zorn-Kruppa, Michaela; Houdek, Pia; Wladykowski, Ewa; Engelke, Maria; Bartok, Melinda; Mewes, Karsten R.; Moll, Ingrid; Brandner, Johanna M.

    2014-01-01

    The depth of injury (DOI) is a mechanistic correlate to the ocular irritation response. Attempts to quantitatively determine the DOI in alternative tests have been limited to ex vivo animal eyes by fluorescent staining for biomarkers of cell death and viability in histological cross sections. It was the purpose of this study to assess whether DOI could also be measured by means of cell viability detected by the MTT assay using 3-dimensional (3D) reconstructed models of cornea and conjunctiva. The formazan-free area of metabolically inactive cells in the tissue after topical substance application is used as the visible correlate of the DOI. Areas of metabolically active or inactive cells are quantitatively analyzed on cryosection images with ImageJ software analysis tools. By incorporating the total tissue thickness, the relative MTT-DOI (rMTT-DOI) was calculated. Using the rMTT-DOI and human reconstructed cornea equivalents, we developed a prediction model based on suitable viability cut-off values. We tested 25 chemicals that cover the whole range of eye irritation potential based on the globally harmonized system of classification and labelling of chemicals (GHS). Principally, the MTT-DOI test method allows distinguishing between the cytotoxic effects of the different chemicals in accordance with all 3 GHS categories for eye irritation. Although the prediction model is slightly over-predictive with respect to non-irritants, it promises to be highly valuable to discriminate between severe irritants (Cat. 1), and mild to moderate irritants (Cat. 2). We also tested 3D conjunctiva models with the aim to specifically address conjunctiva-damaging substances. Using the MTT-DOI method in this model delivers comparable results as the cornea model, but does not add additional information. However, the MTT-DOI method using reconstructed cornea models already provided good predictability that was superior to the already existing established in vitro/ex vivo methods. PMID:25494045

  12. Development of a Carbon Nanotube-Based Micro-CT and its Applications in Preclinical Research

    NASA Astrophysics Data System (ADS)

    Burk, Laurel May

    Due to the dependence of researchers on mouse models for the study of human disease, diagnostic tools available in the clinic must be modified for use on these much smaller subjects. In addition to high spatial resolution, cardiac and lung imaging of mice presents extreme temporal challenges, and physiological gating methods must be developed in order to image these organs without motion blur. Commercially available micro-CT imaging devices are equipped with conventional thermionic x-ray sources and have a limited temporal response and are not ideal for in vivo small animal studies. Recent development of a field-emission x-ray source with carbon nanotube (CNT) cathode in our lab presented the opportunity to create a micro-CT device well-suited for in vivo lung and cardiac imaging of murine models for human disease. The goal of this thesis work was to present such a device, to develop and refine protocols which allow high resolution in vivo imaging of free-breathing mice, and to demonstrate the use of this new imaging tool for the study many different disease models. In Chapter 1, I provide background information about x-rays, CT imaging, and small animal micro-CT. In Chapter 2, CNT-based x-ray sources are explained, and details of a micro-focus x-ray tube specialized for micro-CT imaging are presented. In Chapter 3, the first and second generation CNT micro-CT devices are characterized, and successful respiratory- and cardiac-gated live animal imaging on normal, wild-type mice is achieved. In Chapter 4, respiratory-gated imaging of mouse disease models is demonstrated, limitations to the method are discussed, and a new contactless respiration sensor is presented which addresses many of these limitations. In Chapter 5, cardiac-gated imaging of disease models is demonstrated, including studies of aortic calcification, left ventricular hypertrophy, and myocardial infarction. In Chapter 6, several methods for image and system improvement are explored, and radiation therapy-related micro-CT imaging is present. Finally, in Chapter 7 I discuss future directions for this research and for the CNT micro-CT.

  13. Histological Methods for ex vivo Axon Tracing: A Systematic Review

    PubMed Central

    Heilingoetter, Cassandra L.; Jensen, Matthew B.

    2016-01-01

    Objectives Axon tracers provide crucial insight into the development, connectivity, and function of neural pathways. A tracer can be characterized as a substance that allows for the visualization of a neuronal pathway. Axon tracers have previously been used exclusively with in vivo studies; however, newer methods of axon tracing can be applied to ex vivo studies. Ex vivo studies involve the examination of cells or tissues retrieved from an organism. These post mortem methods of axon tracing offer several advantages, such as reaching inaccessible tissues and avoiding survival surgeries. Methods In order to evaluate the quality of the ex vivo tracing methods, we performed a systematic review of various experimental and comparison studies to discern the optimal method of axon tracing. Results The most prominent methods for ex vivo tracing involve enzymatic techniques or various dyes. It appears that there are a variety of techniques and conditions that tend to give better fluorescent character, clarity, and distance traveled in the neuronal pathway. We found direct comparison studies that looked at variables such as the type of tracer, time required, effect of temperature, and presence of calcium, however, there are other variables that have not been compared directly. Discussion We conclude there are a variety of promising tracing methods available depending on the experimental goals of the researcher, however, more direct comparison studies are needed to affirm the optimal method. PMID:27098542

  14. Ex Vivo Expanded Human Regulatory T Cells Can Prolong Survival of a Human Islet Allograft in a Humanized Mouse Model

    PubMed Central

    Wu, Douglas C.; Hester, Joanna; Nadig, Satish N.; Zhang, Wei; Trzonkowski, Piotr; Gray, Derek; Hughes, Stephen; Johnson, Paul; Wood, Kathryn J.

    2013-01-01

    Background Human regulatory T cells (Treg) offer an attractive adjunctive therapy to reduce current reliance on lifelong, nonspecific immunosuppression after transplantation. Here, we evaluated the ability of ex vivo expanded human Treg to prevent the rejection of islets of Langerhans in a humanized mouse model and examined the mechanisms involved. Methods We engrafted human pancreatic islets of Langerhans into the renal subcapsular space of immunodeficient BALB/c.rag2−/−.cγ−/− mice, previously rendered diabetic via injection of the β-cell toxin streptozocin. After the establishment of stable euglycemia, mice were reconstituted with allogeneic human peripheral blood mononuclear cells (PBMC) and the resultant alloreactive response studied. Ex vivo expanded CD25highCD4+ human Treg, which expressed FoxP3, CTLA-4, and CD62L and remained CD127low, were then cotransferred together with human PBMC and islet allografts and monitored for evidence of rejection. Results Human islets transplanted into diabetic immunodeficient mice reversed diabetes but were rejected rapidly after the mice were reconstituted with allogeneic human PBMC. Cotransfer of purified, ex vivo expanded human Treg prolonged islet allograft survival resulting in the accumulation of Treg in the peripheral lymphoid tissue and suppression of proliferation and interferon-γ production by T cells. In vitro, Treg suppressed activation of signal transducers and activators of transcription and inhibited the effector differentiation of responder T cells. Conclusions Ex vivo expanded Treg retain regulatory activity in vivo, can protect a human islet allograft from rejection by suppressing signal transducers and activators of transcription activation and inhibiting T-cell differentiation, and have clinical potential as an adjunctive cellular therapy. PMID:23917725

  15. Near-infrared-excited confocal Raman spectroscopy advances in vivo diagnosis of cervical precancer.

    PubMed

    Duraipandian, Shiyamala; Zheng, Wei; Ng, Joseph; Low, Jeffrey J H; Ilancheran, Arunachalam; Huang, Zhiwei

    2013-06-01

    Raman spectroscopy is a unique optical technique that can probe the changes of vibrational modes of biomolecules associated with tissue premalignant transformation. This study evaluates the clinical utility of confocal Raman spectroscopy over near-infrared (NIR) autofluorescence (AF) spectroscopy and composite NIR AF/Raman spectroscopy for improving early diagnosis of cervical precancer in vivo at colposcopy. A rapid NIR Raman system coupled with a ball-lens fiber-optic confocal Raman probe was utilized for in vivo NIR AF/Raman spectral measurements of the cervix. A total of 1240 in vivo Raman spectra [normal (n=993), dysplasia (n=247)] were acquired from 84 cervical patients. Principal components analysis (PCA) and linear discriminant analysis (LDA) together with a leave-one-patient-out, cross-validation method were used to extract the diagnostic information associated with distinctive spectroscopic modalities. The diagnostic ability of confocal Raman spectroscopy was evaluated using the PCA-LDA model developed from the significant principal components (PCs) [i.e., PC4, 0.0023%; PC5, 0.00095%; PC8, 0.00022%, (p<0.05)], representing the primary tissue Raman features (e.g., 854, 937, 1095, 1253, 1311, 1445, and 1654 cm(-1)). Confocal Raman spectroscopy coupled with PCA-LDA modeling yielded the diagnostic accuracy of 84.1% (a sensitivity of 81.0% and a specificity of 87.1%) for in vivo discrimination of dysplastic cervix. The receiver operating characteristic curves further confirmed that the best classification was achieved using confocal Raman spectroscopy compared to the composite NIR AF/Raman spectroscopy or NIR AF spectroscopy alone. This study illustrates that confocal Raman spectroscopy has great potential to improve early diagnosis of cervical precancer in vivo during clinical colposcopy.

  16. Deep learning approaches for detection and removal of ghosting artifacts in MR spectroscopy.

    PubMed

    Kyathanahally, Sreenath P; Döring, André; Kreis, Roland

    2018-09-01

    To make use of deep learning (DL) methods to detect and remove ghosting artifacts in clinical magnetic resonance spectra of human brain. Deep learning algorithms, including fully connected neural networks, deep-convolutional neural networks, and stacked what-where auto encoders, were implemented to detect and correct MR spectra containing spurious echo ghost signals. The DL methods were trained on a huge database of simulated spectra with and without ghosting artifacts that represent complex variations of ghost-ridden spectra, transformed to time-frequency spectrograms. The trained model was tested on simulated and in vivo spectra. The preliminary results for ghost detection are very promising, reaching almost 100% accuracy, and the DL ghost removal methods show potential in simulated and in vivo spectra, but need further refinement and quantitative testing. Ghosting artifacts in spectroscopy are problematic, as they superimpose with metabolites and lead to inaccurate quantification. Detection and removal of ghosting artifacts using traditional machine learning approaches with feature extraction/selection is difficult, as ghosts appear at different frequencies. Here, we show that DL methods perform extremely well for ghost detection if the spectra are treated as images in the form of time-frequency representations. Further optimization for in vivo spectra will hopefully confirm their "ghostbusting" capacity. Magn Reson Med 80:851-863, 2018. © 2018 International Society for Magnetic Resonance in Medicine. © 2018 International Society for Magnetic Resonance in Medicine.

  17. The bovine lung in biomedical research: visually guided bronchoscopy, intrabronchial inoculation and in vivo sampling techniques.

    PubMed

    Prohl, Annette; Ostermann, Carola; Lohr, Markus; Reinhold, Petra

    2014-07-03

    There is an ongoing search for alternative animal models in research of respiratory medicine. Depending on the goal of the research, large animals as models of pulmonary disease often resemble the situation of the human lung much better than mice do. Working with large animals also offers the opportunity to sample the same animal repeatedly over a certain course of time, which allows long-term studies without sacrificing the animals. The aim was to establish in vivo sampling methods for the use in a bovine model of a respiratory Chlamydia psittaci infection. Sampling should be performed at various time points in each animal during the study, and the samples should be suitable to study the host response, as well as the pathogen under experimental conditions. Bronchoscopy is a valuable diagnostic tool in human and veterinary medicine. It is a safe and minimally invasive procedure. This article describes the intrabronchial inoculation of calves as well as sampling methods for the lower respiratory tract. Videoendoscopic, intrabronchial inoculation leads to very consistent clinical and pathological findings in all inoculated animals and is, therefore, well-suited for use in models of infectious lung disease. The sampling methods described are bronchoalveolar lavage, bronchial brushing and transbronchial lung biopsy. All of these are valuable diagnostic tools in human medicine and could be adapted for experimental purposes to calves aged 6-8 weeks. The samples obtained were suitable for both pathogen detection and characterization of the severity of lung inflammation in the host.

  18. Ex vivo and in vivo label-free imaging of lymphatic vessels using OCT lymphangiography (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Gong, Peijun; Es'haghian, Shaghayegh; Karnowski, Karol; Rea, Suzanne; Wood, Fiona M.; Yu, Dao-Yi; McLaughlin, Robert A.; Sampson, David D.

    2017-02-01

    We have been developing an automated method to image lymphatic vessels both ex vivo and in vivo with optical coherence tomography (OCT), using their optical transparency. Our method compensates for the OCT signal attenuation for each A-scan in combination with the correction of the confocal function and sensitivity fall-off, enabling reliable thresholding of lymphatic vessels from the OCT scans. Morphological image processing with a segment-joining algorithm is also incorporated into the method to mitigate partial-volume artifacts, which are particularly evident with small lymphatic vessels. Our method is demonstrated for two different clinical application goals: the monitoring of conjunctival lymphatics for surgical guidance and assessment of glaucoma treatment; and the longitudinal monitoring of human burn scars undergoing laser ablation treatment. We present examples of OCT lymphangiography ex vivo on porcine conjunctivas and in vivo on human burn scars, showing the visualization of the lymphatic vessel network and their longitudinal changes due to treatment.

  19. In Vivo Near-Infrared Imaging of Fibrin Deposition in Thromboembolic Stroke in Mice

    PubMed Central

    Zhang, Yi; Fan, Shufeng; Yao, Yuyu; Ding, Jie; Wang, Yu; Zhao, Zhen; Liao, Lei; Li, Peicheng; Zang, Fengchao; Teng, Gao-Jun

    2012-01-01

    Objectives Thrombus and secondary thrombosis plays a key role in stroke. Recent molecular imaging provides in vivo imaging of activated factor XIII (FXIIIa), an important mediator of thrombosis or fibrinolytic resistance. The present study was to investigate the fibrin deposition in a thromboembolic stroke mice model by FXIIIa–targeted near-infrared fluorescence (NIRF) imaging. Materials and Methods The experimental protocol was approved by our institutional animal use committee. Seventy-six C57B/6J mice were subjected to thromboembolic middle cerebral artery occlusion or sham operation. Mice were either intravenously injected with the FXIIIa-targeted probe or control probe. In vivo and ex vivo NIRF imaging were performed thereafter. Probe distribution was assessed with fluorescence microscopy by spectral imaging and quantification system. MR scans were performed to measure lesion volumes in vivo, which were correlated with histology after animal euthanasia. Results In vivo significant higher fluorescence intensity over the ischemia-affected hemisphere, compared to the contralateral side, was detected in mice that received FXIIIa-targeted probe, but not in the controlled mice. Significantly NIRF signals showed time-dependent processes from 8 to 96 hours after injection of FXIIIa-targeted probes. Ex vivo NIRF image showed an intense fluorescence within the ischemic territory only in mice injected with FXIIIa-targeted probe. The fluorescence microscopy demonstrated distribution of FXIIIa-targeted probe in the ischemic region and nearby micro-vessels, and FXIIIa-targeted probe signals showed good overlap with immune-fluorescent fibrin staining images. There was a significant correlation between total targeted signal from in vivo or ex vivo NIRF images and lesion volume. Conclusion Non-invasive detection of fibrin deposition in ischemic mouse brain using NIRF imaging is feasible and this technique may provide an in vivo experimental tool in studying the role of fibrin in stroke. PMID:22272319

  20. Different Therapeutic Outcomes of Benznidazole and VNI Treatments in Different Genders in Mouse Experimental Models of Trypanosoma cruzi Infection

    PubMed Central

    Guedes-da-Silva, F. H.; Batista, D. G. J.; da Silva, C. F.; Meuser, M. B.; Simões-Silva, M. R.; de Araújo, J. S.; Ferreira, C. G.; Moreira, O. C.; Britto, C.; Lepesheva, G. I.

    2015-01-01

    The lack of translation between preclinical assays and clinical trials for novel therapies for Chagas disease (CD) indicates a need for more feasible and standardized protocols and experimental models. Here, we investigated the effects of treatment with benznidazole (Bz) and with the potent experimental T. cruzi CYP51 inhibitor VNI in mouse models of Chagas disease by using different animal genders and parasite strains and employing distinct types of therapeutic schemes. Our findings confirm that female mice are less vulnerable to the infection than males, show that male models are less susceptible to treatment with both Bz and VNI, and thus suggest that male models are much more suitable for selection of the most promising antichagasic agents. Additionally, we have found that preventive protocols (compound given at 1 dpi) result in higher treatment success rates, which also should be avoided during advanced steps of in vivo trials of novel anti-T. cruzi drug candidates. Another consideration is the relevance of immunosuppression methods in order to verify the therapeutic profile of novel compounds, besides the usefulness of molecular diagnostic tools (quantitative PCR) to ascertain compound efficacy in experimental animals. Our study aims to contribute to the development of more reliable methods and decision gates for in vivo assays of novel antiparasitic compounds in order to move them from preclinical to clinical trials for CD. PMID:26416857

  1. Early pharmaceutical profiling to predict oral drug absorption: current status and unmet needs.

    PubMed

    Bergström, Christel A S; Holm, René; Jørgensen, Søren Astrup; Andersson, Sara B E; Artursson, Per; Beato, Stefania; Borde, Anders; Box, Karl; Brewster, Marcus; Dressman, Jennifer; Feng, Kung-I; Halbert, Gavin; Kostewicz, Edmund; McAllister, Mark; Muenster, Uwe; Thinnes, Julian; Taylor, Robert; Mullertz, Anette

    2014-06-16

    Preformulation measurements are used to estimate the fraction absorbed in vivo for orally administered compounds and thereby allow an early evaluation of the need for enabling formulations. As part of the Oral Biopharmaceutical Tools (OrBiTo) project, this review provides a summary of the pharmaceutical profiling methods available, with focus on in silico and in vitro models typically used to forecast active pharmaceutical ingredient's (APIs) in vivo performance after oral administration. An overview of the composition of human, animal and simulated gastrointestinal (GI) fluids is provided and state-of-the art methodologies to study API properties impacting on oral absorption are reviewed. Assays performed during early development, i.e. physicochemical characterization, dissolution profiles under physiological conditions, permeability assays and the impact of excipients on these properties are discussed in detail and future demands on pharmaceutical profiling are identified. It is expected that innovative computational and experimental methods that better describe molecular processes involved in vivo during dissolution and absorption of APIs will be developed in the OrBiTo. These methods will provide early insights into successful pathways (medicinal chemistry or formulation strategy) and are anticipated to increase the number of new APIs with good oral absorption being discovered. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Mechanical properties of porcine brain tissue in vivo and ex vivo estimated by MR elastography.

    PubMed

    Guertler, Charlotte A; Okamoto, Ruth J; Schmidt, John L; Badachhape, Andrew A; Johnson, Curtis L; Bayly, Philip V

    2018-03-01

    The mechanical properties of brain tissue in vivo determine the response of the brain to rapid skull acceleration. These properties are thus of great interest to the developers of mathematical models of traumatic brain injury (TBI) or neurosurgical simulations. Animal models provide valuable insight that can improve TBI modeling. In this study we compare estimates of mechanical properties of the Yucatan mini-pig brain in vivo and ex vivo using magnetic resonance elastography (MRE) at multiple frequencies. MRE allows estimations of properties in soft tissue, either in vivo or ex vivo, by imaging harmonic shear wave propagation. Most direct measurements of brain mechanical properties have been performed using samples of brain tissue ex vivo. It has been observed that direct estimates of brain mechanical properties depend on the frequency and amplitude of loading, as well as the time post-mortem and condition of the sample. Using MRE in the same animals at overlapping frequencies, we observe that porcine brain tissue in vivo appears stiffer than porcine brain tissue samples ex vivo at frequencies of 100 Hz and 125 Hz, but measurements show closer agreement at lower frequencies. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Cytochrome p450 turnover: regulation of synthesis and degradation, methods for determining rates, and implications for the prediction of drug interactions.

    PubMed

    Yang, Jiansong; Liao, Mingxiang; Shou, Magang; Jamei, Masoud; Yeo, Karen Rowland; Tucker, Geoffrey T; Rostami-Hodjegan, Amin

    2008-06-01

    In vivo enzyme levels are governed by the rates of de novo enzyme synthesis and degradation. A current lack of consensus on values of the in vivo turnover half-lives of human cytochrome P450 (CYP) enzymes places a significant limitation on the accurate prediction of changes in drug concentration-time profiles associated with interactions involving enzyme induction and mechanism (time)-based inhibition (MBI). In the case of MBI, the full extent of inhibition is also sensitive to values of enzyme turnover half-life. We review current understanding of CYP regulation, discuss the pros and cons of various in vitro and in vivo approaches used to estimate the turnover of specific CYPs and, by simulation, consider the impact of variability in estimates of CYP turnover on the prediction of enzyme induction and MBI in vivo. In the absence of consensus on values for the in vivo turnover half-lives of key CYPs, a sensitivity analysis of predictions of the pharmacokinetic effects of enzyme induction and MBI to these values should be an integral part of the modelling exercise, and the selective use of values should be avoided.

  4. Bone quantitative susceptibility mapping using a chemical species-specific R2* signal model with ultrashort and conventional echo data.

    PubMed

    Dimov, Alexey V; Liu, Zhe; Spincemaille, Pascal; Prince, Martin R; Du, Jiang; Wang, Yi

    2018-01-01

    To develop quantitative susceptibility mapping (QSM) of bone using an ultrashort echo time (UTE) gradient echo (GRE) sequence for signal acquisition and a bone-specific effective transverse relaxation rate ( R2*) to model water-fat MR signals for field mapping. Three-dimensional radial UTE data (echo times ≥ 40 μs) was acquired on a 3 Tesla scanner and fitted with a bone-specific signal model to map the chemical species and susceptibility field. Experiments were performed ex vivo on a porcine hoof and in vivo on healthy human subjects (n = 7). For water-fat separation, a bone-specific model assigning R2* decay mostly to water was compared with the standard models that assigned the same decay for both fat and water. In the ex vivo experiment, bone QSM was correlated with CT. Compared with standard models, the bone-specific R2* method significantly reduced errors in the fat fraction within the cortical bone in all tested data sets, leading to reduced artifacts in QSM. Good correlation was found between bone CT and QSM values in the porcine hoof (R 2  = 0.77). Bone QSM was successfully generated in all subjects. The QSM of bone is feasible using UTE with a conventional echo time GRE acquisition and a bone-specific R2* signal model. Magn Reson Med 79:121-128, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  5. Dissecting the Mechanisms of Linezolid Resistance in a Drosophila melanogaster Infection Model of Staphylococcus aureus

    PubMed Central

    Diaz, Lorena; Kontoyiannis, Dimitrios P.; Panesso, Diana; Albert, Nathaniel D.; Singh, Kavindra V.; Tran, Truc T.; Munita, Jose M.; Murray, Barbara E.; Arias, Cesar A.

    2013-01-01

    Background. Mini-host models are simple experimental systems to study host-pathogen interactions. We adapted a Drosophila melanogaster infection model to evaluate the in vivo effect of different mechanisms of linezolid (LNZ) resistance in Staphylococcus aureus. Methods. Fly survival was evaluated after infection with LNZ-resistant S. aureus strains NRS119 (which has mutations in 23S ribosomal RNA [rRNA]), CM-05 and 004-737X (which carry cfr), LNZ-susceptible derivatives of CM-05 and 004-737X (which lack cfr), and ATCC 29213 (an LNZ-susceptible control). Flies were then fed food mixed with LNZ (concentration, 15–500 µg/mL). Results were compared to those in mouse peritonitis, using LNZ via oral gavage at 80 and 120 mg/kg every 12 hours. Results. LNZ at 500 µg/mL in fly food protected against all strains, while concentrations of 15–250 µg/mL failed to protect against NRS119 (survival, 1.6%–20%). An in vivo effect of cfr was only detected at concentrations of 30 and 15 µg/mL. In the mouse peritonitis model, LNZ (at doses that mimic human pharmacokinetics) protected mice from challenge with the cfr+ 004-737X strain but was ineffective against the NRS119 strain, which carried 23S rRNA mutations. Conclusions. The fly model offers promising advantages to dissect the in vivo effect of LNZ resistance in S. aureus, and findings from this model appear to be concordant with those from the mouse peritonitis model. PMID:23547139

  6. Application of in vitro bioaccessibility and bioavailability methods for calcium, carotenoids, folate, iron, magnesium, polyphenols, zinc, and vitamins B6, B12, D, and E

    PubMed Central

    Etcheverry, Paz; Grusak, Michael A.; Fleige, Lisa E.

    2012-01-01

    A review of in vitro bioaccessibility and bioavailability methods for polyphenols and selected nutrients is presented. The review focuses on in vitro solubility, dialyzability, the dynamic gastrointestinal model (TIM)™, and Caco-2 cell models, the latter primarily for uptake and transport, and a discussion of how these methods have been applied to generate data for a range of nutrients, carotenoids, and polyphenols. Recommendations are given regarding which methods are most justified for answering bioaccessibility or bioavailability related questions for specific nutrients. The need for more validation studies in which in vivo results are compared to in vitro results is also discussed. PMID:22934067

  7. In-vivo singlet oxygen threshold doses for PDT

    PubMed Central

    Zhu, Timothy C.; Kim, Michele M.; Liang, Xing; Finlay, Jarod C.; Busch, Theresa M.

    2015-01-01

    Objective Dosimetry of singlet oxygen (1O2) is of particular interest because it is the major cytotoxic agent causing biological effects for type-II photosensitizers during photodynamic therapy (PDT). An in-vivo model to determine the singlet oxygen threshold dose, [1O2]rx,sh, for PDT was developed. Material and methods An in-vivo radiation-induced fibrosarcoma (RIF) tumor mouse model was used to correlate the radius of necrosis to the calculation based on explicit PDT dosimetry of light fluence distribution, tissue optical properties, and photosensitizer concentrations. Inputs to the model include five photosensitizer-specific photochemical parameters along with [1O2]rx,sh. Photosensitizer-specific model parameters were determined for benzoporphyrin derivative monoacid ring A (BPD) and compared with two other type-II photosensitizers, Photofrin® and m-tetrahydroxyphenylchlorin (mTHPC) from the literature. Results The mean values (standard deviation) of the in-vivo [1O2]rx,sh are approximately 0.56 (0.26) and 0.72 (0.21) mM (or 3.6×107 and 4.6×107 singlet oxygen per cell to reduce the cell survival to 1/e) for Photofrin® and BPD, respectively, assuming that the fraction of generated singlet oxygen that interacts with the cell is 1. While the values for the photochemical parameters (ξ, σ, g, β) used for BPD were preliminary and may need further refinement, there is reasonable confidence for the values of the singlet oxygen threshold doses. Discussion In comparison, the [1O2]rx,sh value derived from in-vivo mouse study was reported to be 0.4 mM for mTHPC-PDT. However, the singlet oxygen required per cell is reported to be 9×108 per cell per 1/e fractional kill in an in-vitro mTHPC-PDT study on a rat prostate cancer cell line (MLL cells) and is reported to be 7.9 mM for a multicell in-vitro EMT6/Ro spheroid model for mTHPC-PDT. A theoretical analysis is provided to relate the number of in-vitro singlet oxygen required per cell to reach cell killing of 1/e to in-vivo singlet oxygen threshold dose (in mM). The sensitivity of threshold singlet oxygen dose for our experiment is examined. The possible influence of vascular vs. apoptotic cell killing mechanisms on the singlet oxygen threshold dose is discussed by comparing [1O2]rx,sh for BPD with 3 hr and 15 min drug-light-intervals, with the later being known to have a dominantly vascular effect. Conclusions The experimental results of threshold singlet oxygen concentration in an in-vivo RIF tumor model for Photofrin®, BPD, and mTHPC are about 20 times smaller than those observed in vitro. These results are consistent with knowledge that factors other than singlet oxygen-mediated tumor cell killing can contribute to PDT damage in-vivo. PMID:25927018

  8. Preclinical safety assessments of nano-sized constructs on cardiovascular system toxicity: A case for telemetry.

    PubMed

    Cheah, Hoay Yan; Kiew, Lik Voon; Lee, Hong Boon; Japundžić-Žigon, Nina; Vicent, Marίa J; Hoe, See Ziau; Chung, Lip Yong

    2017-11-01

    While nano-sized construct (NSC) use in medicine has grown significantly in recent years, reported unwanted side effects have raised safety concerns. However, the toxicity of NSCs to the cardiovascular system (CVS) and the relative merits of the associated evaluation methods have not been thoroughly studied. This review discusses the toxicological profiles of selected NSCs and provides an overview of the assessment methods, including in silico, in vitro, ex vivo and in vivo models and how they are related to CVS toxicity. We conclude the review by outlining the merits of telemetry coupled with spectral analysis, baroreceptor reflex sensitivity analysis and echocardiography as an appropriate integrated strategy for the assessment of the acute and chronic impact of NSCs on the CVS. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  9. In vivo detection of free radicals using molecular MRI and immuno-spin trapping in a mouse model for amyotrophic lateral sclerosis.

    PubMed

    Towner, Rheal A; Smith, Nataliya; Saunders, Debra; Lupu, Florea; Silasi-Mansat, Robert; West, Melinda; Ramirez, Dario C; Gomez-Mejiba, Sandra E; Bonini, Marcelo G; Mason, Ronald P; Ehrenshaft, Marilyn; Hensley, Kenneth

    2013-10-01

    Free radicals associated with oxidative stress play a major role in amyotrophic lateral sclerosis (ALS). By combining immuno-spin trapping and molecular magnetic resonance imaging, in vivo trapped radical adducts were detected in the spinal cords of SOD1(G93A)-transgenic (Tg) mice, a model for ALS. For this study, the nitrone spin trap DMPO (5,5-dimethyl-1-pyrroline N-oxide) was administered (ip) over 5 days before administration (iv) of an anti-DMPO probe (anti-DMPO antibody covalently bound to an albumin-gadolinium-diethylenetriamine pentaacetic acid-biotin MRI contrast agent) to trap free radicals. MRI was used to detect the presence of the anti-DMPO radical adducts by a significant sustained increase in MR signal intensities (p < 0.05) or anti-DMPO probe concentrations measured from T₁ relaxations (p < 0.01). The biotin moiety of the anti-DMPO probe was targeted with fluorescence-labeled streptavidin to locate the probe in excised tissues. Negative controls included either Tg ALS mice initially administered saline rather than DMPO followed by the anti-DMPO probe or non-Tg mice initially administered DMPO and then the anti-DMPO probe. The anti-DMPO probe was found to bind to neurons via colocalization fluorescence microscopy. DMPO adducts were also confirmed in diseased/nondiseased tissues from animals administered DMPO. Apparent diffusion coefficients from diffusion-weighted images of spinal cords from Tg mice were significantly elevated (p < 0.001) compared to wild-type controls. This is the first report regarding the detection of in vivo trapped radical adducts in an ALS model. This novel, noninvasive, in vivo diagnostic method can be applied to investigate the involvement of free radical mechanisms in ALS rodent models. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Histological methods for ex vivo axon tracing: A systematic review.

    PubMed

    Heilingoetter, Cassandra L; Jensen, Matthew B

    2016-07-01

    Axon tracers provide crucial insight into the development, connectivity, and function of neural pathways. A tracer can be characterized as a substance that allows for the visualization of a neuronal pathway. Axon tracers have previously been used exclusively with in vivo studies; however, newer methods of axon tracing can be applied to ex vivo studies. Ex vivo studies involve the examination of cells or tissues retrieved from an organism. These post mortem methods of axon tracing offer several advantages, such as reaching inaccessible tissues and avoiding survival surgeries. In order to evaluate the quality of the ex vivo tracing methods, we performed a systematic review of various experimental and comparison studies to discern the optimal method of axon tracing. The most prominent methods for ex vivo tracing involve enzymatic techniques or various dyes. It appears that there are a variety of techniques and conditions that tend to give better fluorescent character, clarity, and distance traveled in the neuronal pathway. We found direct comparison studies that looked at variables such as the type of tracer, time required, effect of temperature, and presence of calcium, however, there are other variables that have not been compared directly. We conclude there are a variety of promising tracing methods available depending on the experimental goals of the researcher, however, more direct comparison studies are needed to affirm the optimal method.

  11. Microstructure Imaging of Crossing (MIX) White Matter Fibers from diffusion MRI

    PubMed Central

    Farooq, Hamza; Xu, Junqian; Nam, Jung Who; Keefe, Daniel F.; Yacoub, Essa; Georgiou, Tryphon; Lenglet, Christophe

    2016-01-01

    Diffusion MRI (dMRI) reveals microstructural features of the brain white matter by quantifying the anisotropic diffusion of water molecules within axonal bundles. Yet, identifying features such as axonal orientation dispersion, density, diameter, etc., in complex white matter fiber configurations (e.g. crossings) has proved challenging. Besides optimized data acquisition and advanced biophysical models, computational procedures to fit such models to the data are critical. However, these procedures have been largely overlooked by the dMRI microstructure community and new, more versatile, approaches are needed to solve complex biophysical model fitting problems. Existing methods are limited to models assuming single fiber orientation, relevant to limited brain areas like the corpus callosum, or multiple orientations but without the ability to extract detailed microstructural features. Here, we introduce a new and versatile optimization technique (MIX), which enables microstructure imaging of crossing white matter fibers. We provide a MATLAB implementation of MIX, and demonstrate its applicability to general microstructure models in fiber crossings using synthetic as well as ex-vivo and in-vivo brain data. PMID:27982056

  12. Non-Invasive in vivo Mapping and Long-Term Monitoring of Magnetic Nanoparticles in Different Organs of Animals

    NASA Astrophysics Data System (ADS)

    Nikitin, Maxim; Yuriev, Mikhail; Brusentsov, Nikolai; Vetoshko, Petr; Nikitin, Petr

    2010-12-01

    Quantitative detection of magnetic nanoparticles (MP) in vivo is very important for various biomedical applications. Our original detection method based on non-linear MP magnetization has been modified for non-invasive in vivo mapping of the MP distribution among different organs of rats. A novel highly sensitive room-temperature device equipped with an external probe has been designed and tested for quantification of MP within 20-mm depth from the animal skin. Results obtained by external in vivo scanning of rats by the probe and ex vivo MP quantification in different organs of rats well correlated. The method allows long-term in vivo study of MP evolution, clearance and redistribution among different organs of the animal. Experiments showed that dynamics in vivo strongly depend on MP characteristics (size, material, coatings, etc.), site of injection and dose. The developed detection method combined with the magnetic nanolabels can substitute the radioactive labeling in many applications.

  13. Patient-specific musculoskeletal modeling of the hip joint for preoperative planning of total hip arthroplasty: A validation study based on in vivo measurements

    PubMed Central

    Schick, Fabian; Asseln, Malte; Damm, Philipp; Radermacher, Klaus

    2018-01-01

    Validation of musculoskeletal models for application in preoperative planning is still a challenging task. Ideally, the simulation results of a patient-specific musculoskeletal model are compared to corresponding in vivo measurements. Currently, the only possibility to measure in vivo joint forces is to implant an instrumented prosthesis in patients undergoing a total joint replacement. In this study, a musculoskeletal model of the AnyBody Modeling System was adapted patient-specifically and validated against the in vivo hip joint force measurements of ten subjects performing one-leg stance and level walking. The impact of four model parameters was evaluated; hip joint width, muscle strength, muscle recruitment, and type of muscle model. The smallest difference between simulated and in vivo hip joint force was achieved by using the hip joint width measured in computed tomography images, a muscle strength of 90 N/cm2, a third order polynomial muscle recruitment, and a simple muscle model. This parameter combination reached mean deviations between simulation and in vivo measurement during the peak force phase of 12% ± 14% in magnitude and 11° ± 5° in orientation for one-leg stance and 8% ± 6% in magnitude and 10° ± 5° in orientation for level walking. PMID:29649235

  14. Artificial Cervical Vertebra and Intervertebral Complex Replacement through the Anterior Approach in Animal Model: A Biomechanical and In Vivo Evaluation of a Successful Goat Model

    PubMed Central

    Qin, Jie; He, Xijing; Wang, Dong; Qi, Peng; Guo, Lei; Huang, Sihua; Cai, Xuan; Li, Haopeng; Wang, Rui

    2012-01-01

    This was an in vitro and in vivo study to develop a novel artificial cervical vertebra and intervertebral complex (ACVC) joint in a goat model to provide a new method for treating degenerative disc disease in the cervical spine. The objectives of this study were to test the safety, validity, and effectiveness of ACVC by goat model and to provide preclinical data for a clinical trial in humans in future. We designed the ACVC based on the radiological and anatomical data on goat and human cervical spines, established an animal model by implanting the ACVC into goat cervical spines in vitro prior to in vivo implantation through the anterior approach, and evaluated clinical, radiological, biomechanical parameters after implantation. The X-ray radiological data revealed similarities between goat and human intervertebral angles at the levels of C2-3, C3-4, and C4-5, and between goat and human lordosis angles at the levels of C3-4 and C4-5. In the in vivo implantation, the goats successfully endured the entire experimental procedure and recovered well after the surgery. The radiological results showed that there was no dislocation of the ACVC and that the ACVC successfully restored the intervertebral disc height after the surgery. The biomechanical data showed that there was no significant difference in range of motion (ROM) or neural zone (NZ) between the control group and the ACVC group in flexion-extension and lateral bending before or after the fatigue test. The ROM and NZ of the ACVC group were greater than those of the control group for rotation. In conclusion, the goat provides an excellent animal model for the biomechanical study of the cervical spine. The ACVC is able to provide instant stability after surgery and to preserve normal motion in the cervical spine. PMID:23300816

  15. Design and in vivo evaluation of carvedilol buccal mucoadhesive patches.

    PubMed

    Thimmasetty, J; Pandey, G S; Babu, P R Sathesh

    2008-07-01

    The buccal region offers an attractive route of administration for systemic drug delivery. Carvedilol (dose, 3.125-25 mg) is beta-adrenergic antagonist. Its oral bioavailability is 25-35% because of first pass metabolism. Buccal absorption studies of a carvedilol solution in human volunteers showed 32.86% drug absorption. FTIR and UV spectroscopic methods revealed that there was no interaction between carvedilol and polymers. Carvedilol patches were prepared using HPMC, carbopol 934, eudragit RS 100, and ethylcellulose. The patches were evaluated for their thickness uniformity, folding endurance, weight uniformity, content uniformity, swelling behaviour, tensile strength, and surface pH. In vitro release studies were conducted for carvedilol-loaded patches in phosphate buffer (pH, 6.6) solution. Patches exhibited drug release in the range of 86.26 to 98.32% in 90 min. Data of in vitro release from patches were fit to different equations and kinetic models to explain release profiles. Kinetic models used were zero and first-order equations, Hixon-Crowell, Higuchi, and Korsmeyer-Peppas models. In vivo drug release studies in rabbits showed 90.85% of drug release from HPMC-carbopol patch while it was 74.63 to 88.02% within 90 min in human volunteers. Good correlation among in vitro release and in vivo release of carvedilol was observed.

  16. Use of TSHβ:EGFP transgenic zebrafish as a rapid in vivo model for assessing thyroid-disrupting chemicals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ji, Cheng; Graduate University of Chinese Academy of Sciences, Beijing; Jin, Xia

    Accumulating evidence indicates that a wide range of chemicals have the ability to interfere with the hypothalamic–pituitary–thyroid (HPT) axis. Novel endpoints should be evaluated in addition to existing methods in order to effectively assess the effects of these chemicals on the HPT axis. Thyroid-stimulating hormone subunit β (TSHβ) plays central regulatory roles in the HPT system. We identified the regulatory region that determines the expression level of zebrafish TSHβ in the anterior pituitary. In the transgenic zebrafish with EGFP driven by the TSHβ promoter, the similar responsive patterns between the expression levels of TSHβ:EGFP and endogenous TSHβ mRNA in themore » pituitary are observed following treatments with goitrogen chemicals and exogenous thyroid hormones (THs). These results suggest that the TSHβ:EGFP transgenic reporter zebrafish may be a useful alternative in vivo model for the assessment of chemicals interfering with the HPT system. Highlights: ► The promoter of zebrafish TSHβ gene has been identified. ► The stable TSHβ:EGFP transgenic zebrafish reporter germline has been generated. ► The EGFP in the transgenic fish recapitulated the pattern of pituitary TSHβ mRNA. ► The transgenic zebrafish may be an in vivo model for EDC assessment.« less

  17. Review of Modelling Techniques for In Vivo Muscle Force Estimation in the Lower Extremities during Strength Training.

    PubMed

    Schellenberg, Florian; Oberhofer, Katja; Taylor, William R; Lorenzetti, Silvio

    2015-01-01

    Knowledge of the musculoskeletal loading conditions during strength training is essential for performance monitoring, injury prevention, rehabilitation, and training design. However, measuring muscle forces during exercise performance as a primary determinant of training efficacy and safety has remained challenging. In this paper we review existing computational techniques to determine muscle forces in the lower limbs during strength exercises in vivo and discuss their potential for uptake into sports training and rehabilitation. Muscle forces during exercise performance have almost exclusively been analysed using so-called forward dynamics simulations, inverse dynamics techniques, or alternative methods. Musculoskeletal models based on forward dynamics analyses have led to considerable new insights into muscular coordination, strength, and power during dynamic ballistic movement activities, resulting in, for example, improved techniques for optimal performance of the squat jump, while quasi-static inverse dynamics optimisation and EMG-driven modelling have helped to provide an understanding of low-speed exercises. The present review introduces the different computational techniques and outlines their advantages and disadvantages for the informed usage by nonexperts. With sufficient validation and widespread application, muscle force calculations during strength exercises in vivo are expected to provide biomechanically based evidence for clinicians and therapists to evaluate and improve training guidelines.

  18. HTS Data and In Silico Models for High-Throughout Risk Assessment (FutureTox II)

    EPA Science Inventory

    A significant challenge in toxicology is the “too many chemicals” problem. Humans and environmental species are exposed to as many as tens of thousands of chemicals, few of which have been thoroughly tested using standard in vivo test methods. This talk will discuss several appro...

  19. A Novel Two-Step Hierarchial Quantitative Structure-Activity Relationship Modeling Workflow for Predicting Acute Toxicity of Chemicals in Rodents

    EPA Science Inventory

    Background: Accurate prediction of in vivo toxicity from in vitro testing is a challenging problem. Large public–private consortia have been formed with the goal of improving chemical safety assessment by the means of high-throughput screening. Methods and results: A database co...

  20. Virtual Liver: integrating in vitro and in vivo data to predict chemical-induced toxicity

    EPA Science Inventory

    It is difficult to assess the health impact of long-term exposure to low levels of contaminants from animal studies. Current methods for testing the toxicity of a single chemical can cost millions of dollars, take up to two years and sacrifice thousands of animals. In vitro model...

  1. Preclinical Performance Evaluation of Percutaneous Glucose Biosensors: Experimental Considerations and Recommendations.

    PubMed

    Soto, Robert J; Schoenfisch, Mark H

    2015-06-17

    The utility of continuous glucose monitoring devices remains limited by an obstinate foreign body response (FBR) that degrades the analytical performance of the in vivo sensor. A number of novel materials that resist or delay the FBR have been proposed as outer, tissue-contacting glucose sensor membranes as a strategy to improve sensor accuracy. Traditionally, researchers have examined the ability of a material to minimize the host response by assessing adsorbed cell morphology and tissue histology. However, these techniques do not adequately predict in vivo glucose sensor function, necessitating sensor performance evaluation in a relevant animal model prior to human testing. Herein, the effects of critical experimental parameters, including the animal model and data processing methods, on the reliability and usefulness of preclinical sensor performance data are considered. © 2015 Diabetes Technology Society.

  2. Er:YAG laser-induced changes in skin in vivo and transdermal drug delivery

    NASA Astrophysics Data System (ADS)

    Flock, Stephen T.; Stern, Tom; Lehman, Paul; Dinehart, Scott; Franz, Tom; Liu, George; Stern, Scott J.

    1997-05-01

    It has been shown that laser ablation of stratum corneum, in vitro, can result in an increased uptake of topically applied pharmaceuticals. We have performed measurements of drug permeation, using an in vitro model of human skin, that involves a portable Er:YAG laser used to ablate the stratum corneum. For the first time, this method of drug administration was tested in vivo in human volunteers, whereby a hydrocortisone blanching assay was used to assess the efficiency of the procedure. The results show that this is a safe and efficient way to ablate stratum corneum for the purpose of enhanced transcutaneous drug administration.

  3. Synchrotron phase-contrast X-ray imaging reveals fluid dosing dynamics for gene transfer into mouse airways.

    PubMed

    Donnelley, M; Siu, K K W; Jamison, R A; Parsons, D W

    2012-01-01

    Although airway gene transfer research in mouse models relies on bolus fluid dosing into the nose or trachea, the dynamics and immediate fate of delivered gene transfer agents are poorly understood. In particular, this is because there are no in vivo methods able to accurately visualize the movement of fluid in small airways of intact animals. Using synchrotron phase-contrast X-ray imaging, we show that the fate of surrogate fluid doses delivered into live mouse airways can now be accurately and non-invasively monitored with high spatial and temporal resolution. This new imaging approach can help explain the non-homogenous distributions of gene expression observed in nasal airway gene transfer studies, suggests that substantial dose losses may occur at deliver into mouse trachea via immediate retrograde fluid motion and shows the influence of the speed of bolus delivery on the relative targeting of conducting and deeper lung airways. These findings provide insight into some of the factors that can influence gene expression in vivo, and this method provides a new approach to documenting and analyzing dose delivery in small-animal models.

  4. Comparison of optical projection tomography and optical coherence tomography for assessment of murine embryonic development

    NASA Astrophysics Data System (ADS)

    Singh, Manmohan; Nair, Achuth; Vadakkan, Tegy; Piazza, Victor; Udan, Ryan; Frazier, Michael V.; Janecek, Trevor; Dickinson, Mary E.; Larin, Kirill V.

    2015-03-01

    The murine model is a common model for studying developmental diseases. In this study, we compare the performance of the relatively new method of Optical Projection Tomography (OPT) to the well-established technique of Optical Coherence Tomography (OCT) to assess murine embryonic development at three stages, 9.5, 11.5, and 13.5 days post conception. While both methods can provide spatial resolution at the micrometer scale, OPT can provide superior imaging depth compared to OCT. However, OPT requires samples to be fixed, placed in an immobilization media such as agar, and cleared before imaging. Because OCT does not require fixing, it can be used to image embryos in vivo and in utero. In this study, we compare the efficacy of OPT and OCT for imaging murine embryonic development. The data demonstrate the superior capability of OPT for imaging fine structures with high resolution in optically-cleared embryos while only OCT can provide structural and functional imaging of live embryos ex vivo and in utero with micrometer scale resolution.

  5. AN INVERSE MODELING APPROACH FOR STRESS ESTIMATION IN MITRAL VALVE ANTERIOR LEAFLET VALVULOPLASTY FOR IN-VIVO VALVULAR BIOMATERIAL ASSESSMENT

    PubMed Central

    Lee, Chung-Hao; Amini, Rouzbeh; Gorman, Robert C.; Gorman, Joseph H.; Sacks, Michael S.

    2013-01-01

    Estimation of regional tissue stresses in the functioning heart valve remains an important goal in our understanding of normal valve function and in developing novel engineered tissue strategies for valvular repair and replacement. Methods to accurately estimate regional tissue stresses are thus needed for this purpose, and in particular to develop accurate, statistically informed means to validate computational models of valve function. Moreover, there exists no currently accepted method to evaluate engineered heart valve tissues and replacement heart valve biomaterials undergoing valvular stresses in blood contact. While we have utilized mitral valve anterior leaflet valvuloplasty as an experimental approach to address this limitation, robust computational techniques to estimate implant stresses are required. In the present study, we developed a novel numerical analysis approach for estimation of the in-vivo stresses of the central region of the mitral valve anterior leaflet (MVAL) delimited by a sonocrystal transducer array. The in-vivo material properties of the MVAL were simulated using an inverse FE modeling approach based on three pseudo-hyperelastic constitutive models: the neo-Hookean, exponential-type isotropic, and full collagen-fiber mapped transversely isotropic models. A series of numerical replications with varying structural configurations were developed by incorporating measured statistical variations in MVAL local preferred fiber directions and fiber splay. These model replications were then used to investigate how known variations in the valve tissue microstructure influence the estimated ROI stresses and its variation at each time point during a cardiac cycle. Simulations were also able to include estimates of the variation in tissue stresses for an individual specimen dataset over the cardiac cycle. Of the three material models, the transversely anisotropic model produced the most accurate results, with ROI averaged stresses at the fully-loaded state of 432.6±46.5 kPa and 241.4±40.5 kPa in the radial and circumferential directions, respectively. We conclude that the present approach can provide robust instantaneous mean and variation estimates of tissue stresses of the central regions of the MVAL. PMID:24275434

  6. Macromolecule mapping of the brain using ultrashort-TE acquisition and reference-based metabolite removal.

    PubMed

    Lam, Fan; Li, Yudu; Clifford, Bryan; Liang, Zhi-Pei

    2018-05-01

    To develop a practical method for mapping macromolecule distribution in the brain using ultrashort-TE MRSI data. An FID-based chemical shift imaging acquisition without metabolite-nulling pulses was used to acquire ultrashort-TE MRSI data that capture the macromolecule signals with high signal-to-noise-ratio (SNR) efficiency. To remove the metabolite signals from the ultrashort-TE data, single voxel spectroscopy data were obtained to determine a set of high-quality metabolite reference spectra. These spectra were then incorporated into a generalized series (GS) model to represent general metabolite spatiospectral distributions. A time-segmented algorithm was developed to back-extrapolate the GS model-based metabolite distribution from truncated FIDs and remove it from the MRSI data. Numerical simulations and in vivo experiments have been performed to evaluate the proposed method. Simulation results demonstrate accurate metabolite signal extrapolation by the proposed method given a high-quality reference. For in vivo experiments, the proposed method is able to produce spatiospectral distributions of macromolecules in the brain with high SNR from data acquired in about 10 minutes. We further demonstrate that the high-dimensional macromolecule spatiospectral distribution resides in a low-dimensional subspace. This finding provides a new opportunity to use subspace models for quantification and accelerated macromolecule mapping. Robustness of the proposed method is also demonstrated using multiple data sets from the same and different subjects. The proposed method is able to obtain macromolecule distributions in the brain from ultrashort-TE acquisitions. It can also be used for acquiring training data to determine a low-dimensional subspace to represent the macromolecule signals for subspace-based MRSI. Magn Reson Med 79:2460-2469, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  7. An in vitro test bench reproducing coronary blood flow signals.

    PubMed

    Chodzyński, Kamil Jerzy; Boudjeltia, Karim Zouaoui; Lalmand, Jacques; Aminian, Adel; Vanhamme, Luc; de Sousa, Daniel Ribeiro; Gremmo, Simone; Bricteux, Laurent; Renotte, Christine; Courbebaisse, Guy; Coussement, Grégory

    2015-08-07

    It is a known fact that blood flow pattern and more specifically the pulsatile time variation of shear stress on the vascular wall play a key role in atherogenesis. The paper presents the conception, the building and the control of a new in vitro test bench that mimics the pulsatile flows behavior based on in vivo measurements. An in vitro cardiovascular simulator is alimented with in vivo constraints upstream and provided with further post-processing analysis downstream in order to mimic the pulsatile in vivo blood flow quantities. This real-time controlled system is designed to perform real pulsatile in vivo blood flow signals to study endothelial cells' behavior under near physiological environment. The system is based on an internal model controller and a proportional-integral controller that controls a linear motor with customized piston pump, two proportional-integral controllers that control the mean flow rate and temperature of the medium. This configuration enables to mimic any resulting blood flow rate patterns between 40 and 700 ml/min. In order to feed the system with reliable periodic flow quantities in vivo measurements were performed. Data from five patients (1 female, 4 males; ages 44-63) were filtered and post-processed using the Newtonian Womersley's solution. These resulting flow signals were compared with 2D axisymmetric, numerical simulation using a Carreau non-Newtonian model to validate the approximation of a Newtonian behavior. This in vitro test bench reproduces the measured flow rate time evolution and the complexity of in vivo hemodynamic signals within the accuracy of the relative error below 5%. This post-processing method is compatible with any real complex in vivo signal and demonstrates the heterogeneity of pulsatile patterns in coronary arteries among of different patients. The comparison between analytical and numerical solution demonstrate the fair quality of the Newtonian Womersley's approximation. Therefore, Womersley's solution was used to calculate input flow rate for the in vitro test bench.

  8. In Vitro and In Vivo Activities of Antimicrobial Peptides Developed Using an Amino Acid-Based Activity Prediction Method

    PubMed Central

    Wu, Xiaozhe; Wang, Zhenling; Li, Xiaolu; Fan, Yingzi; He, Gu; Wan, Yang; Yu, Chaoheng; Tang, Jianying; Li, Meng; Zhang, Xian; Zhang, Hailong; Xiang, Rong; Pan, Ying; Liu, Yan; Lu, Lian

    2014-01-01

    To design and discover new antimicrobial peptides (AMPs) with high levels of antimicrobial activity, a number of machine-learning methods and prediction methods have been developed. Here, we present a new prediction method that can identify novel AMPs that are highly similar in sequence to known peptides but offer improved antimicrobial activity along with lower host cytotoxicity. Using previously generated AMP amino acid substitution data, we developed an amino acid activity contribution matrix that contained an activity contribution value for each amino acid in each position of the model peptide. A series of AMPs were designed with this method. After evaluating the antimicrobial activities of these novel AMPs against both Gram-positive and Gram-negative bacterial strains, DP7 was chosen for further analysis. Compared to the parent peptide HH2, this novel AMP showed broad-spectrum, improved antimicrobial activity, and in a cytotoxicity assay it showed lower toxicity against human cells. The in vivo antimicrobial activity of DP7 was tested in a Staphylococcus aureus infection murine model. When inoculated and treated via intraperitoneal injection, DP7 reduced the bacterial load in the peritoneal lavage solution. Electron microscope imaging and the results indicated disruption of the S. aureus outer membrane by DP7. Our new prediction method can therefore be employed to identify AMPs possessing minor amino acid differences with improved antimicrobial activities, potentially increasing the therapeutic agents available to combat multidrug-resistant infections. PMID:24982064

  9. Limitations of predicting in vivo biostability of multiphase polyurethane elastomers using temperature-accelerated degradation testing.

    PubMed

    Padsalgikar, Ajay; Cosgriff-Hernandez, Elizabeth; Gallagher, Genevieve; Touchet, Tyler; Iacob, Ciprian; Mellin, Lisa; Norlin-Weissenrieder, Anna; Runt, James

    2015-01-01

    Polyurethane biostability has been the subject of intense research since the failure of polyether polyurethane pacemaker leads in the 1980s. Accelerated in vitro testing has been used to isolate degradation mechanisms and predict clinical performance of biomaterials. However, validation that in vitro methods reproduce in vivo degradation is critical to the selection of appropriate tests. High temperature has been proposed as a method to accelerate degradation. However, correlation of such data to in vivo performance is poor for polyurethanes due to the impact of temperature on microstructure. In this study, we characterize the lack of correlation between hydrolytic degradation predicted using a high temperature aging model of a polydimethylsiloxane-based polyurethane and its in vivo performance. Most notably, the predicted molecular weight and tensile property changes from the accelerated aging study did not correlate with clinical explants subjected to human biological stresses in real time through 5 years. Further, DMTA, ATR-FTIR, and SAXS experiments on samples aged for 2 weeks in PBS indicated greater phase separation in samples aged at 85°C compared to those aged at 37°C and unaged controls. These results confirm that microstructural changes occur at high temperatures that do not occur at in vivo temperatures. In addition, water absorption studies demonstrated that water saturation levels increased significantly with temperature. This study highlights that the multiphase morphology of polyurethane precludes the use of temperature accelerated biodegradation for the prediction of clinical performance and provides critical information in designing appropriate in vitro tests for this class of materials. © 2014 Wiley Periodicals, Inc.

  10. Can we use an ex vivo continuous hemofiltration model to describe the adsorption and elimination of meropenem and piperacillin?

    PubMed

    Jamal, Janattul-Ain; Udy, Andrew A; Wallis, Steven C; Ranganathan, Dwarakanathan; McWhinney, Brett C; Ungerer, Jacobus P J; Lipman, Jeffrey; Roberts, Jason A

    2015-08-01

    To determine the adsorption and elimination characteristics of meropenem and piperacillin during simulated continuous renal replacement therapy (CRRT), and to compare the observed data from this ex vivo study with previous data from clinical studies. This was an experimental study utilizing a modified CRRT circuit and polysulfone membrane (1.2 m2), circulated with a blood-crystalloid mixture. Adsorption onto the CRRT circuit was tested over a 4-h period, and clearance was assessed separately using variable continuous hemofiltration settings. A rapid 9% reduction in circulating meropenem and piperacillin concentrations was observed at approximately 0.5 and 1.0 h for each antibiotic, respectively. The post-dilution setting was associated with a significantly higher sieving coefficient (Sc) and filter clearance (CLfilter) (mean ± SD) (Sc 1.14 ± 0.10 versus 1.06 ± 0.04; CLfilter 19.05 ± 1.63 versus 17.59 ± 0.62 ml/min, P values < 0.05) for meropenem. No significant differences were observed for piperacillin pharmacokinetics. Clinically comparable Sc data were observed between data obtained from the ex vivo study and data from previous clinical studies, for both antibiotics. Meropenem and piperacillin appear to be rapidly adsorbed into the CRRT circuit, and the delivery site of fluid replacement significantly influences meropenem pharmacokinetics. However, these findings are likely to be clinically insignificant and not affect dosing requirements. This ex vivo method could be a surrogate for future clinical pharmacokinetic studies of CRRT. Further research is required to explore the applicability of the ex vivo method to further characterize antibiotic pharmacokinetics during CRRT.

  11. Microwave Ablation: Comparison of Simultaneous and Sequential Activation of Multiple Antennas in Liver Model Systems.

    PubMed

    Harari, Colin M; Magagna, Michelle; Bedoya, Mariajose; Lee, Fred T; Lubner, Meghan G; Hinshaw, J Louis; Ziemlewicz, Timothy; Brace, Christopher L

    2016-01-01

    To compare microwave ablation zones created by using sequential or simultaneous power delivery in ex vivo and in vivo liver tissue. All procedures were approved by the institutional animal care and use committee. Microwave ablations were performed in both ex vivo and in vivo liver models with a 2.45-GHz system capable of powering up to three antennas simultaneously. Two- and three-antenna arrays were evaluated in each model. Sequential and simultaneous ablations were created by delivering power (50 W ex vivo, 65 W in vivo) for 5 minutes per antenna (10 and 15 minutes total ablation time for sequential ablations, 5 minutes for simultaneous ablations). Thirty-two ablations were performed in ex vivo bovine livers (eight per group) and 28 in the livers of eight swine in vivo (seven per group). Ablation zone size and circularity metrics were determined from ablations excised postmortem. Mixed effects modeling was used to evaluate the influence of power delivery, number of antennas, and tissue type. On average, ablations created by using the simultaneous power delivery technique were larger than those with the sequential technique (P < .05). Simultaneous ablations were also more circular than sequential ablations (P = .0001). Larger and more circular ablations were achieved with three antennas compared with two antennas (P < .05). Ablations were generally smaller in vivo compared with ex vivo. The use of multiple antennas and simultaneous power delivery creates larger, more confluent ablations with greater temperatures than those created with sequential power delivery. © RSNA, 2015.

  12. The synergy of honokiol and fluconazole against clinical isolates of azole-resistant Candida albicans.

    PubMed

    Jin, J; Guo, N; Zhang, J; Ding, Y; Tang, X; Liang, J; Li, L; Deng, X; Yu, L

    2010-09-01

    To evaluate the interaction of fluconazole (FLC) and honokiol (HNK) in vitro and vivo against azole-resistant (azole-R) clinical isolates of Candida albicans. A checkerboard microdilution method was used to study the in vitro interaction of FLC and HNK in 24 azole-R clinical isolates of C. albicans. In vivo antifungal activity was performed to further analyse the interaction between FLC and HNK. In the in vitro study, synergism was observed in all 24 FLC-resistant strains tested as determined by fractional inhibitory concentration index (FICI), and in 22 strains by Delta E models. No antagonistic activity was observed in any of the strains tested. These positive interactions were also confirmed by using the time-killing test for the selected strain C. albicans YL371, which shows strong susceptible to the combination of HNK and FLC. In the in vivo study, the mice with candidiasis were treated successfully by a combination therapy of HNK with FLC, the results showed a decrease of the colony forming unit in infected and treated animals compared to the controls, at the conditions of the treatment used in this study. Synergistic activity of HNK and FLC against clinical isolates of FLC-resistant C. albicans was observed in vitro and in vivo. This report might provide a potential therapeutic method to overcome the problem of drug-resistance in C. albicans.

  13. Quantified pH imaging with hyperpolarized (13) C-bicarbonate.

    PubMed

    Scholz, David Johannes; Janich, Martin A; Köllisch, Ulrich; Schulte, Rolf F; Ardenkjaer-Larsen, Jan H; Frank, Annette; Haase, Axel; Schwaiger, Markus; Menzel, Marion I

    2015-06-01

    Because pH plays a crucial role in several diseases, it is desirable to measure pH in vivo noninvasively and in a spatially localized manner. Spatial maps of pH were quantified in vitro, with a focus on method-based errors, and applied in vivo. In vitro and in vivo (13) C mapping were performed for various flip angles for bicarbonate (BiC) and CO2 with spectral-spatial excitation and spiral readout in healthy Lewis rats in five slices. Acute subcutaneous sterile inflammation was induced with Concanavalin A in the right leg of Buffalo rats. pH and proton images were measured 2 h after induction. After optimizing the signal to noise ratio of the hyperpolarized (13) C-bicarbonate, error estimation of the spectral-spatial excited spectrum reveals that the method covers the biologically relevant pH range of 6 to 8 with low pH error (< 0.2). Quantification of pH maps shows negligible impact of the residual bicarbonate signal. pH maps reflect the induction of acute metabolic alkalosis. Inflamed, infected regions exhibit lower pH. Hyperpolarized (13) C-bicarbonate pH mapping was shown to be sensitive in the biologically relevant pH range. The mapping of pH was applied to healthy in vivo organs and interpreted within inflammation and acute metabolic alkalosis models. © 2014 Wiley Periodicals, Inc.

  14. Drug drug interaction extraction from the literature using a recursive neural network

    PubMed Central

    Lim, Sangrak; Lee, Kyubum

    2018-01-01

    Detecting drug-drug interactions (DDI) is important because information on DDIs can help prevent adverse effects from drug combinations. Since there are many new DDI-related papers published in the biomedical domain, manually extracting DDI information from the literature is a laborious task. However, text mining can be used to find DDIs in the biomedical literature. Among the recently developed neural networks, we use a Recursive Neural Network to improve the performance of DDI extraction. Our recursive neural network model uses a position feature, a subtree containment feature, and an ensemble method to improve the performance of DDI extraction. Compared with the state-of-the-art models, the DDI detection and type classifiers of our model performed 4.4% and 2.8% better, respectively, on the DDIExtraction Challenge’13 test data. We also validated our model on the PK DDI corpus that consists of two types of DDIs data: in vivo DDI and in vitro DDI. Compared with the existing model, our detection classifier performed 2.3% and 6.7% better on in vivo and in vitro data respectively. The results of our validation demonstrate that our model can automatically extract DDIs better than existing models. PMID:29373599

  15. Antimicrobial Blue Light Therapy for Infectious Keratitis: Ex Vivo and In Vivo Studies.

    PubMed

    Zhu, Hong; Kochevar, Irene E; Behlau, Irmgard; Zhao, Jie; Wang, Fenghua; Wang, Yucheng; Sun, Xiaodong; Hamblin, Michael R; Dai, Tianhong

    2017-01-01

    To investigate the effectiveness of antimicrobial blue light (aBL) as an alternative or adjunctive therapeutic for infectious keratitis. We developed an ex vivo rabbit model and an in vivo mouse model of infectious keratitis. A bioluminescent strain of Pseudomonas aeruginosa was used as the causative pathogen, allowing noninvasive monitoring of the extent of infection in real time via bioluminescence imaging. Quantitation of bacterial luminescence was correlated to colony-forming units (CFU). Using the ex vivo and in vivo models, the effectiveness of aBL (415 nm) for the treatment of keratitis was evaluated as a function of radiant exposure when aBL was delivered at 6 or 24 hours after bacterial inoculation. The aBL exposures calculated to reach the retina were compared to the American National Standards Institute standards to estimate aBL retinal safety. Pseudomonas aeruginosa keratitis fully developed in both the ex vivo and in vivo models at 24 hours post inoculation. Bacterial luminescence in the infected corneas correlated linearly to CFU (R2 = 0.921). Bacterial burden in the infected corneas was rapidly and significantly reduced (>2-log10) both ex vivo and in vivo after a single exposure of aBL. Recurrence of infection was observed in the aBL-treated mice at 24 hours after aBL exposure. The aBL toxicity to the retina is largely dependent on the aBL transmission of the cornea. Antimicrobial blue light is a potential alternative or adjunctive therapeutic for infectious keratitis. Further studies of corneal and retinal safety using large animal models, in which the ocular anatomies are similar to that of humans, are warranted.

  16. Comparison of In Vivo and Ex Vivo MRI for the Detection of Structural Abnormalities in a Mouse Model of Tauopathy

    PubMed Central

    Holmes, Holly E.; Powell, Nick M.; Ma, Da; Ismail, Ozama; Harrison, Ian F.; Wells, Jack A.; Colgan, Niall; O'Callaghan, James M.; Johnson, Ross A.; Murray, Tracey K.; Ahmed, Zeshan; Heggenes, Morten; Fisher, Alice; Cardoso, M. Jorge; Modat, Marc; O'Neill, Michael J.; Collins, Emily C.; Fisher, Elizabeth M. C.; Ourselin, Sébastien; Lythgoe, Mark F.

    2017-01-01

    With increasingly large numbers of mouse models of human disease dedicated to MRI studies, compromises between in vivo and ex vivo MRI must be fully understood in order to inform the choice of imaging methodology. We investigate the application of high resolution in vivo and ex vivo MRI, in combination with tensor-based morphometry (TBM), to uncover morphological differences in the rTg4510 mouse model of tauopathy. The rTg4510 mouse also offers a novel paradigm by which the overexpression of mutant tau can be regulated by the administration of doxycycline, providing us with a platform on which to investigate more subtle alterations in morphology with morphometry. Both in vivo and ex vivo MRI allowed the detection of widespread bilateral patterns of atrophy in the rTg4510 mouse brain relative to wild-type controls. Regions of volume loss aligned with neuronal loss and pathological tau accumulation demonstrated by immunohistochemistry. When we sought to investigate more subtle structural alterations in the rTg4510 mice relative to a subset of doxycycline-treated rTg4510 mice, ex vivo imaging enabled the detection of more regions of morphological brain changes. The disadvantages of ex vivo MRI may however mitigate this increase in sensitivity: we observed a 10% global shrinkage in brain volume of the post-mortem tissues due to formalin fixation, which was most notable in the cerebellum and olfactory bulbs. However, many central brain regions were not adversely affected by the fixation protocol, perhaps due to our “in-skull” preparation. The disparity between our TBM findings from in vivo and ex vivo MRI underlines the importance of appropriate study design, given the trade-off between these two imaging approaches. We support the utility of in vivo MRI for morphological phenotyping of mouse models of disease; however, for subtler phenotypes, ex vivo offers enhanced sensitivity to discrete morphological changes. PMID:28408879

  17. Comparison of In Vivo and Ex Vivo MRI for the Detection of Structural Abnormalities in a Mouse Model of Tauopathy.

    PubMed

    Holmes, Holly E; Powell, Nick M; Ma, Da; Ismail, Ozama; Harrison, Ian F; Wells, Jack A; Colgan, Niall; O'Callaghan, James M; Johnson, Ross A; Murray, Tracey K; Ahmed, Zeshan; Heggenes, Morten; Fisher, Alice; Cardoso, M Jorge; Modat, Marc; O'Neill, Michael J; Collins, Emily C; Fisher, Elizabeth M C; Ourselin, Sébastien; Lythgoe, Mark F

    2017-01-01

    With increasingly large numbers of mouse models of human disease dedicated to MRI studies, compromises between in vivo and ex vivo MRI must be fully understood in order to inform the choice of imaging methodology. We investigate the application of high resolution in vivo and ex vivo MRI, in combination with tensor-based morphometry (TBM), to uncover morphological differences in the rTg4510 mouse model of tauopathy. The rTg4510 mouse also offers a novel paradigm by which the overexpression of mutant tau can be regulated by the administration of doxycycline, providing us with a platform on which to investigate more subtle alterations in morphology with morphometry. Both in vivo and ex vivo MRI allowed the detection of widespread bilateral patterns of atrophy in the rTg4510 mouse brain relative to wild-type controls. Regions of volume loss aligned with neuronal loss and pathological tau accumulation demonstrated by immunohistochemistry. When we sought to investigate more subtle structural alterations in the rTg4510 mice relative to a subset of doxycycline-treated rTg4510 mice, ex vivo imaging enabled the detection of more regions of morphological brain changes. The disadvantages of ex vivo MRI may however mitigate this increase in sensitivity: we observed a 10% global shrinkage in brain volume of the post-mortem tissues due to formalin fixation, which was most notable in the cerebellum and olfactory bulbs. However, many central brain regions were not adversely affected by the fixation protocol, perhaps due to our "in-skull" preparation. The disparity between our TBM findings from in vivo and ex vivo MRI underlines the importance of appropriate study design, given the trade-off between these two imaging approaches. We support the utility of in vivo MRI for morphological phenotyping of mouse models of disease; however, for subtler phenotypes, ex vivo offers enhanced sensitivity to discrete morphological changes.

  18. A data-driven soft sensor for needle deflection in heterogeneous tissue using just-in-time modelling.

    PubMed

    Rossa, Carlos; Lehmann, Thomas; Sloboda, Ronald; Usmani, Nawaid; Tavakoli, Mahdi

    2017-08-01

    Global modelling has traditionally been the approach taken to estimate needle deflection in soft tissue. In this paper, we propose a new method based on local data-driven modelling of needle deflection. External measurement of needle-tissue interactions is collected from several insertions in ex vivo tissue to form a cloud of data. Inputs to the system are the needle insertion depth, axial rotations, and the forces and torques measured at the needle base by a force sensor. When a new insertion is performed, the just-in-time learning method estimates the model outputs given the current inputs to the needle-tissue system and the historical database. The query is compared to every observation in the database and is given weights according to some similarity criteria. Only a subset of historical data that is most relevant to the query is selected and a local linear model is fit to the selected points to estimate the query output. The model outputs the 3D deflection of the needle tip and the needle insertion force. The proposed approach is validated in ex vivo multilayered biological tissue in different needle insertion scenarios. Experimental results in five different case studies indicate an accuracy in predicting needle deflection of 0.81 and 1.24 mm in the horizontal and vertical lanes, respectively, and an accuracy of 0.5 N in predicting the needle insertion force over 216 needle insertions.

  19. Development of in vitro-in vivo correlation of parenteral naltrexone loaded polymeric microspheres.

    PubMed

    Andhariya, Janki V; Shen, Jie; Choi, Stephanie; Wang, Yan; Zou, Yuan; Burgess, Diane J

    2017-06-10

    Establishment of in vitro-in vivo correlations (IVIVCs) for parenteral polymeric microspheres has been very challenging, due to their complex multiphase release characteristics (which is affected by the nature of the drug) as well as the lack of compendial in vitro release testing methods. Previously, a Level A correlation has been established and validated for polymeric microspheres containing risperidone (a practically water insoluble small molecule drug). The objectives of the present study were: 1) to investigate whether a Level A IVIVC can be established for polymeric microspheres containing another small molecule drug with different solubility profiles compared to risperidone; and 2) to determine whether release characteristic differences (bi-phasic vs tri-phasic) between microspheres can affect the development and predictability of IVIVCs. Naltrexone was chosen as the model drug. Three compositionally equivalent formulations of naltrexone microspheres with different release characteristics were prepared using different manufacturing processes. The critical physicochemical properties (such as drug loading, particle size, porosity, and morphology) as well as the in vitro release characteristics of the prepared naltrexone microspheres and the reference-listed drug (Vivitrol®) were determined. The pharmacokinetics of the naltrexone microspheres were investigated using a rabbit model. The obtained pharmacokinetic profiles were deconvoluted using the Loo-Riegelman method, and compared with the in vitro release profiles of the naltrexone microspheres obtained using USP apparatus 4. Level A IVIVCs were established and validated for predictability. The results demonstrated that the developed USP 4 method was capable of detecting manufacturing process related performance changes, and most importantly, predicting the in vivo performance of naltrexone microspheres in the investigated animal model. A critical difference between naltrexone and risperidone loaded microspheres is their respective bi-phasic and tri-phasic release profiles with varying burst release and lag phase. These variations in release profiles affect the development of IVIVCs. Nevertheless, IVIVCs have been established and validated for polymeric microspheres with different release characteristics. Copyright © 2017. Published by Elsevier B.V.

  20. Immersed boundary-finite element model of fluid-structure interaction in the aortic root

    NASA Astrophysics Data System (ADS)

    Flamini, Vittoria; DeAnda, Abe; Griffith, Boyce E.

    2016-04-01

    It has long been recognized that aortic root elasticity helps to ensure efficient aortic valve closure, but our understanding of the functional importance of the elasticity and geometry of the aortic root continues to evolve as increasingly detailed in vivo imaging data become available. Herein, we describe a fluid-structure interaction model of the aortic root, including the aortic valve leaflets, the sinuses of Valsalva, the aortic annulus, and the sinotubular junction, that employs a version of Peskin's immersed boundary (IB) method with a finite element description of the structural elasticity. As in earlier work, we use a fiber-based model of the valve leaflets, but this study extends earlier IB models of the aortic root by employing an incompressible hyperelastic model of the mechanics of the sinuses and ascending aorta using a constitutive law fit to experimental data from human aortic root tissue. In vivo pressure loading is accounted for by a backward displacement method that determines the unloaded configuration of the root model. Our model yields realistic cardiac output at physiological pressures, with low transvalvular pressure differences during forward flow, minimal regurgitation during valve closure, and realistic pressure loads when the valve is closed during diastole. Further, results from high-resolution computations indicate that although the detailed leaflet and root kinematics show some grid sensitivity, our IB model of the aortic root nonetheless produces essentially grid-converged flow rates and pressures at practical grid spacings for the high Reynolds number flows of the aortic root. These results thereby clarify minimum grid resolutions required by such models when used as stand-alone models of the aortic valve as well as when used to provide models of the outflow valves in models of left-ventricular fluid dynamics.

  1. In vitro and in vivo investigation of taste-masking effectiveness of Eudragit E PO as drug particle coating agent in orally disintegrating tablets.

    PubMed

    Drašković, Milica; Medarević, Djordje; Aleksić, Ivana; Parojčić, Jelena

    2017-05-01

    Considering that bitter taste of drugs incorporated in orally disintegrating tablets (ODTs) can be the main reason for avoiding drug therapy, it is of the utmost importance to achieve successful taste-masking. The evaluation of taste-masking effectiveness is still a major challenge. The objective of this study was to mask bitter taste of the selected model drugs by drug particle coating with Eudragit ® E PO, as well as to evaluate taste-masking effectiveness of prepared ODTs using compendial dissolution testing, dissolution in the small-volume shake-flask assembly and trained human taste panel. Model drugs were coated in fluidized bed. Disintequik™ ODT was used as a novel co-processed excipient for ODT preparation. Selected formulations were investigated in vitro and in vivo using techniques for taste-masking assessment. Significantly slower drug dissolution was observed from tablets with coated drug particles during the first 3 min of investigation. Results of in vivo taste-masking assessment demonstrated significant improvement in drug bitterness suppression in formulations with coated drug. Strong correlation between the results of drug dissolution in the small-volume shake-flask assembly and in vivo evaluation data was established (R ≥ 0.970). Drug particle coating with Eudragit ® E PO can be a suitable approach for bitter taste-masking. Strong correlation between in vivo and in vitro results implicate that small-volume dissolution method may be used as surrogate for human panel taste-masking assessment, in the case of physical taste-masking approach application.

  2. Prediction of Relative In Vivo Metabolite Exposure from In Vitro Data Using Two Model Drugs: Dextromethorphan and Omeprazole

    PubMed Central

    Lutz, Justin D.

    2012-01-01

    Metabolites can have pharmacological or toxicological effects, inhibit metabolic enzymes, and be used as probes of drug-drug interactions or specific cytochrome P450 (P450) phenotypes. Thus, better understanding and prediction methods are needed to characterize metabolite exposures in vivo. This study aimed to test whether in vitro data could be used to predict and rationalize in vivo metabolite exposures using two model drugs and P450 probes: dextromethorphan and omeprazole with their primary metabolites dextrorphan, 5-hydroxyomeprazole (5OH-omeprazole), and omeprazole sulfone. Relative metabolite exposures were predicted using metabolite formation and elimination clearances. For dextrorphan, the formation clearances of dextrorphan glucuronide and 3-hydroxymorphinan from dextrorphan in human liver microsomes were used to predict metabolite (dextrorphan) clearance. For 5OH-omeprazole and omeprazole sulfone, the depletion rates of the metabolites in human hepatocytes were used to predict metabolite clearance. Dextrorphan/dextromethorphan in vivo metabolite/parent area under the plasma concentration versus time curve ratio (AUCm/AUCp) was overpredicted by 2.1-fold, whereas 5OH-omeprazole/omeprazole and omeprazole sulfone/omeprazole were predicted within 0.75- and 1.1-fold, respectively. The effect of inhibition or induction of the metabolite's formation and elimination on the AUCm/AUCp ratio was simulated. The simulations showed that unless metabolite clearance pathways are characterized, interpretation of the metabolic ratios is exceedingly difficult. This study shows that relative in vivo metabolite exposure can be predicted from in vitro data and characterization of secondary metabolism of probe metabolites is critical for interpretation of phenotypic data. PMID:22010218

  3. The effect of a dual or a triple antithrombotic therapy with apixaban on thrombus formation in vivo and in an ex vivo perfusion chamber model

    PubMed Central

    Weisshaar, Stefan; Litschauer, Brigitte; Bucher, Sebastian; Riesenhuber, Martin; Kapiotis, Stylianos; Kyrle, Paul Alexander; Wolzt, Michael

    2016-01-01

    Abstract Background: There is a need to optimize pharmacological treatment in patients with acute coronary syndrome and concomitant atrial fibrillation, in particular with newer antithrombotic medicines. We have therefore studied if dual or triple combination of antithrombotic agents exert similar effects on coagulation activation in an in vivo model in the skin microvasculature and in an ex vivo perfusion chamber. Methods and Results: Shed blood platelet activation (β-thromboglobulin [β-TG]), thrombin generation (thrombin-antithrombin complex [TAT]) and volume as well as markers of thrombus size (D-dimer) and its platelet content (P-selectin) in a perfusion chamber were studied in a sequential, open-label, parallel group trial in 40 healthy male volunteers (n = 20 per group). Subjects received ticagrelor and apixaban without or with acetylsalicylic acid (ASA). Outcome parameters were assessed at 3 hours after therapy dosing, and at steady-state trough and peak conditions. A triple or dual therapy induced a comparable decrease in shed blood β-TG at 3 hours after therapy dosing but was more pronounced at steady-state conditions with the more intense treatment combination. During both antithrombotic regimens a similarly sustained inhibition in thrombin generation was observed which was accompanied by comparable increases in shed blood volume. In contrast, no treatment effect could be observed in the perfusion chamber experiment. Conclusion: Ticagrelor and apixaban with or without ASA inhibit platelet activation and thrombin formation in vivo in healthy subjects. Platelet inhibition was greater at steady-state conditions after triple therapy administration. PMID:27399131

  4. A novel antiangiogenic peptide derived from hepatocyte growth factor inhibits neovascularization in vitro and in vivo

    PubMed Central

    Xu, Yi; Zhao, Hui; Zheng, Ying; Gu, Qing; Ma, Jianxing

    2010-01-01

    Purpose To study the antiangiogenic activity of two small peptides (H-RN and H-FT) derived from the hepatocyte growth factor kringle 1 domain (HGF K1) using in vitro and in vivo assays. Methods RF/6A rhesus macaque choroid-retina endothelial cells were used for in vitro studies. The inhibiting effect of two peptides on a vascular endothelial growth factor (VEGF)-stimulated cell proliferation, cell migration, and endothelial cell tube formation were investigated. For in vivo assays, the antiangiogenic activity of H-RN and H-FT in the chick chorioallantoic membrane model (CAM) and a mice oxygen-induced retinopathy model (OIR) were studied. A recombinant mouse VEGF-neutralizing antibody, bevacizumab, and a scrambled peptide were used as two control groups in separate studies. Results H-RN effectively inhibited VEGF-stimulated RF/6A cell proliferation, migration, and tube formation on Matrigel™, while H-FT did not. H-RN was also able to inhibit angiogenesis when applied to the CAM, and had antineovascularization activity in the retinal neovascularization of a mouse OIR model when administrated as an intravitreous injection. The antiangiogenic activity of H-RN was not as strong as that of VEGF antibodies. The H-FT and scrambled peptide had no such activity. Conclusions H-RN, a new peptide derived from the HGF K1 domain, was shown to have antiangiogenic activity in vitro and in vivo. It may lead to new potential drug discoveries and the development of new treatments for pathological retinal angiogenesis. PMID:21031024

  5. In vitro and in vivo radiosensitization induced by hydroxyapatite nanoparticles

    PubMed Central

    Chu, Sheng-Hua; Karri, Surya; Ma, Yan-Bin; Feng, Dong-Fu; Li, Zhi-Qiang

    2013-01-01

    Background Previous study showed that hydroxyapatite nanoparticles (nano-HAPs) inhibited glioma growth in vitro and in vivo; and in a drug combination, they could reduce adverse reactions. We investigated the possible enhancement of radiosensitivity induced by nano-HAPs. Methods In vitro radiosensitization of nano-HAPs was measured using a clonogenic survival assay in human glioblastoma U251 and breast tumor brain metastatic tumor MDA-MB-231BR cells. DNA damage and repair were measured using γH2AX foci, and mitotic catastrophe was determined by immunostaining. The effect of nano-HAPs on in vivo tumor radiosensitivity was investigated in a subcutaneous and an orthotopic model. Results Nano-HAPs enhanced each cell line's radiosensitivity when the exposure was 1 h before irradiation, and they had no significant effect on irradiation-induced apoptosis or on the activation of the G2 cell cycle checkpoint. The number of γH2AX foci per cell was significantly large at 24 h after the combination modality of nano-HAPs + irradiation compared with single treatments. Mitotic catastrophe was also significantly increased at an interval of 72 h in tumor cells receiving the combined modality compared with the individual treatments. In a subcutaneous model, nano-HAPs caused a larger than additive increase in tumor growth delay. In an orthotopic model, nano-HAPs significantly reduced tumor growth and extended the prolongation of survival induced by irradiation. Conclusions These results show that nano-HAPs can enhance the radiosensitivity of tumor cells in vitro and in vivo through the inhibition of DNA repair, resulting in an increase in mitotic catastrophe. PMID:23519742

  6. Celecoxib interferes to a limited extent with aspirin‐mediated inhibition of platelets aggregation

    PubMed Central

    Ruzov, Mark; Rimon, Gilad; Pikovsky, Oleg

    2015-01-01

    Aims The aim of the study was to analyze the interaction between celecoxib and low dose aspirin for COX‐1 binding and its consequences on the aspirin‐mediated antiplatelet effects. Methods We investigated ex vivo the interaction between celecoxib and aspirin for COX‐1 binding and measured the resulting antiplatelet effects. We applied mechanism‐based pharmacokinetic−pharmacodynamic (PKPD) modelling to analyze these data and to predict in vivo platelet aggregation for different doses and administration schedules of aspirin and celecoxib. Results The predictions of the PK‐PD model were consistent with results from previous studies that investigated interaction between aspirin and celecoxib. The modelling results indicate that celecoxib can attenuate to a limited extent the in vivo antiplatelet effects of low dose aspirin. The extent of this interaction can be substantial (up to 15% increase in platelet aggregation by 200 mg day−1 celecoxib when combined with low dose aspirin) during the first days of aspirin administration in patients who are already treated with celecoxib, and it cannot be prevented by separate administration of the interacting drugs. Conclusions At the recommended therapeutic doses, celecoxib can attenuate to a limited extent the in vivo antiplatelet effects of low dose aspirin. Patients receiving a combination of low dose aspirin and the recommended doses of celecoxib were not identified to have increased risk of cardiovascular and cerebrovascular events due to competition between these drugs for COX‐1 binding. Interaction between low dose aspirin and other COX‐2 inhibitors and its clinical consequences requires further investigation. PMID:26456703

  7. Wavelength optimization for in vivo multispectral photoacoustic/ultrasound tomography of hemoglobin oxygenation in ovarian cancer: clinical studies

    NASA Astrophysics Data System (ADS)

    Salehi, Hassan S.; Li, Hai; Kumavor, Patrick D.; Merkulov, Aleksey; Sanders, Melinda; Brewer, Molly; Zhu, Quing

    2015-03-01

    In this paper, wavelength selection for multispectral photoacoustic/ultrasound tomography was optimized to obtain accurate images of hemoglobin oxygen saturation (sO2) in vivo. Although wavelengths can be selected by theoretical methods, in practice the accuracy of reconstructed images will be affected by wavelength-specific and system-specific factors such as laser source power and ultrasound transducer sensitivity. By performing photoacoustic spectroscopy of mouse tumor models using 14 different wavelengths between 710 and 840 nm, we were able to identify a wavelength set which most accurately reproduced the results obtained using all 14 wavelengths via selection criteria. In clinical studies, the optimal wavelength set was successfully used to image human ovaries in vivo and noninvasively. Although these results are specific to our co-registered photoacoustic/ultrasound imaging system, the approach we developed can be applied to other functional photoacoustic and optical imaging systems.

  8. Whole-Brain Microscopy Meets In Vivo Neuroimaging: Techniques, Benefits, and Limitations.

    PubMed

    Aswendt, Markus; Schwarz, Martin; Abdelmoula, Walid M; Dijkstra, Jouke; Dedeurwaerdere, Stefanie

    2017-02-01

    Magnetic resonance imaging, positron emission tomography, and optical imaging have emerged as key tools to understand brain function and neurological disorders in preclinical mouse models. They offer the unique advantage of monitoring individual structural and functional changes over time. What remained unsolved until recently was to generate whole-brain microscopy data which can be correlated to the 3D in vivo neuroimaging data. Conventional histological sections are inappropriate especially for neuronal tracing or the unbiased screening for molecular targets through the whole brain. As part of the European Society for Molecular Imaging (ESMI) meeting 2016 in Utrecht, the Netherlands, we addressed this issue in the Molecular Neuroimaging study group meeting. Presentations covered new brain clearing methods, light sheet microscopes for large samples, and automatic registration of microscopy to in vivo imaging data. In this article, we summarize the discussion; give an overview of the novel techniques; and discuss the practical needs, benefits, and limitations.

  9. In Vivo Cancer Biomarkers of Esophageal Neoplasia

    PubMed Central

    Lu, Shaoying; Wang, Thomas D

    2011-01-01

    Summary The emergence of in vivo cancer biomarkers is promising tool for early detection, risk stratification, and therapeutic intervention in the esophagus, where adenocarcinoma is increasing at a rate that is faster than any other in industrialized nations. Exciting advances in target identification, probe development, and optical instrumentation are creating tremendous new opportunities for advancing techniques of molecular imaging. Progress in these areas is being made with small animal models of esophageal cancer using surgical approaches to induce reflux of acid and bile, and these findings are beginning to be evaluated in the clinic. Further identification of relevant targets, characterization of specific probes, and development of endoscopic imaging technologies are needed to further this direction in the field of molecular medicine. In the future, new methods that use in vivo cancer biomarkers for the early detection of neoplastic changes in the setting of Barrett's esophagus will become available. PMID:19126962

  10. Combined multi-spectrum and orthogonal Laplacianfaces for fast CB-XLCT imaging with single-view data

    NASA Astrophysics Data System (ADS)

    Zhang, Haibo; Geng, Guohua; Chen, Yanrong; Qu, Xuan; Zhao, Fengjun; Hou, Yuqing; Yi, Huangjian; He, Xiaowei

    2017-12-01

    Cone-beam X-ray luminescence computed tomography (CB-XLCT) is an attractive hybrid imaging modality, which has the potential of monitoring the metabolic processes of nanophosphors-based drugs in vivo. Single-view data reconstruction as a key issue of CB-XLCT imaging promotes the effective study of dynamic XLCT imaging. However, it suffers from serious ill-posedness in the inverse problem. In this paper, a multi-spectrum strategy is adopted to relieve the ill-posedness of reconstruction. The strategy is based on the third-order simplified spherical harmonic approximation model. Then, an orthogonal Laplacianfaces-based method is proposed to reduce the large computational burden without degrading the imaging quality. Both simulated data and in vivo experimental data were used to evaluate the efficiency and robustness of the proposed method. The results are satisfactory in terms of both location and quantitative recovering with computational efficiency, indicating that the proposed method is practical and promising for single-view CB-XLCT imaging.

  11. In vivo assessment of the effect of taxifolin glycoside on atopic dermatitis-like skin lesions using biomedical tools in NC/Nga mice.

    PubMed

    Kim, J Y; Lee, O S; Ha, S; Kim, J H; Park, G; Kim, J K; Oh, C H

    2015-07-01

    Noninvasive methods of assessment are widely used in clinical trials. However, such methods have not been established in atopic dermatitis (AD), which is a chronic inflammatory skin disease. To demonstrate, using biomedical tools, the benefits of a new substance, taxifolin glycoside (TAX), in an AD model, the NC/Nga mouse. We evaluated the efficacy of topical TAX for AD by measuring clinical skin severity score, cytokine expression and serum IgE level, and by using biomedical measures (vapometry and corneometry). Topical TAX was applied to AD-induced NC/Nga mice for 3 weeks. The anti-inflammatory effects of this compound were demonstrated noninvasively using biomedical tools and immunological assays. Our method of AD assessment using biomedical tools is more objective and accurate than visual inspection. The results obtained using the biomedical tools were identical to those obtained using immunological assays. In vivo biomedical tools are useful for diagnosing and monitoring treatment effects in AD. © 2014 British Association of Dermatologists.

  12. Histoculture and the immunodeficient mouse come to the cancer clinic - rational approaches to individualizing cancer-therapy and new drug-evaluation (review).

    PubMed

    Hoffman, R

    1992-09-01

    Originating from the experiments of Alexis Carrel, tissues in culture were originally grown in three dimensions and maintained important in vivo-like structural and functional properties. However, in modem times, monolayer cell culture methods have become predominant despite losses of structural and functional properties of the cells. Strangeways, Fell, Leighton, Sutherland and others have designed various methods of three-dimensional culture using cellulose supports, mesh supports, collagen gel or sponge supports and floatation that allow tissues to maintain many in vivo-like properties such as native architecture, differentiated functions, gene regulation, invasive properties and drug sensitivities which are very different than cells in monolayer cultures. Collagen-sponge-gel-supported histoculture has been shown to support the growth and native three-dimensional architecture of both tumor and normal tissue, often for long periods of time. This method of histoculture was utilized to develop a chemosensitivity assay for individual cancer patients by assessing the effects of drug on the patients' histocultured tumor. Various end points to measure drug response have been utilized in histoculture, including [H-3]thymidine incorporation measured by histological autoradiography and the use of vital dyes to indicate cell viability. The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-2H tetrazolium bromide (MTT) end point was applied to the histoculture assay in an attempt to increase in vitro-in vivo correlation. The chemosensitivities of 16 human tumor lines were determined in vitro by the histoculture assay, and retrospectively correlated to their in vivo chemosensitivity as xenografts in nude mice. The overall correlation rate of the efficacy results of the drug-response assay to in vivo chemosensitivities was 89.8%, with 90.0% true-positive and 89.7% true-negative rates, 81.7% sensitivity and 94.6% specificity, thereby indicating potential clinical use for tumor histoculture with the MTT end point. The data reviewed and analyzed here thus indicate that three-dimensional culture systems offer much more realistic model systems for evaluating potential new cancer agents and individualized treatment such as predictive drug-response testing. The 'MetaMouse' model developed in our laboratory allows direct 'onplantation' of intact patient surgical cancer specimens orthotopically to athymic 'nude' mice with high-level expression of local growth on the target organ and high metastatic potential. Eight MetaMouse human cancer models are reviewed including those for the colon, bladder, lung, stomach, prostate, ovary, pancreas and head and neck. The human tumors growing and metastasizing in the mice reflect the clinical situation and should be useful for new drug evaluation and development of strategies for individual treatment. The combined technologies of histoculture and MetaMouse thus offer an integrated in vitro-in vivo system for preclinical evaluation of experimental and standard cancer therapy.

  13. Basement Membrane-Based Glucose Sensor Coatings Enhance Continuous Glucose Monitoring in Vivo

    PubMed Central

    Klueh, Ulrike; Qiao, Yi; Czajkowski, Caroline; Ludzinska, Izabela; Antar, Omar; Kreutzer, Donald L.

    2015-01-01

    Background: Implantable glucose sensors demonstrate a rapid decline in function that is likely due to biofouling of the sensor. Previous efforts directed at overcoming this issue has generally focused on the use of synthetic polymer coatings, with little apparent effect in vivo, clearly a novel approach is required. We believe that the key to extending sensor life span in vivo is the development of biocompatible basement membrane (BM) based bio-hydrogels as coatings for glucose sensors. Method: BM based bio-hydrogel sensor coatings were developed using purified BM preparations (ie, Cultrex from Trevigen Inc). Modified Abbott sensors were coated with Cultrex BM extracts. Sensor performance was evaluated for the impact of these coatings in vitro and in vivo in a continuous glucose monitoring (CGM) mouse model. In vivo sensor function was assessed over a 28-day time period expressed as mean absolute relative difference (MARD) values. Tissue reactivity of both Cultrex coated and uncoated glucose sensors was evaluated at 7, 14, 21 and 28 days post–sensor implantation with standard histological techniques. Results: The data demonstrate that Cultrex-based sensor coatings had no effect on glucose sensor function in vitro. In vivo glucose sensor performance was enhanced following BM coating as determined by MARD analysis, particularly in weeks 2 and 3. In vivo studies also demonstrated that Cultrex coatings significantly decreased sensor-induced tissue reactions at the sensor implantation sites. Conclusion: Basement-membrane-based sensor coatings enhance glucose sensor function in vivo, by minimizing or preventing sensor-induced tissues reactions. PMID:26306494

  14. Toxicity assessment of industrial chemicals and airborne contaminants: transition from in vivo to in vitro test methods: a review.

    PubMed

    Bakand, S; Winder, C; Khalil, C; Hayes, A

    2005-12-01

    Exposure to occupational and environmental contaminants is a major contributor to human health problems. Inhalation of gases, vapors, aerosols, and mixtures of these can cause a wide range of adverse health effects, ranging from simple irritation to systemic diseases. Despite significant achievements in the risk assessment of chemicals, the toxicological database, particularly for industrial chemicals, remains limited. Considering there are approximately 80,000 chemicals in commerce, and an extremely large number of chemical mixtures, in vivo testing of this large number is unachievable from both economical and practical perspectives. While in vitro methods are capable of rapidly providing toxicity information, regulatory agencies in general are still cautious about the replacement of whole-animal methods with new in vitro techniques. Although studying the toxic effects of inhaled chemicals is a complex subject, recent studies demonstrate that in vitro methods may have significant potential for assessing the toxicity of airborne contaminants. In this review, current toxicity test methods for risk evaluation of industrial chemicals and airborne contaminants are presented. To evaluate the potential applications of in vitro methods for studying respiratory toxicity, more recent models developed for toxicity testing of airborne contaminants are discussed.

  15. The robustness and accuracy of in vivo linear wear measurements for knee prostheses based on model-based RSA.

    PubMed

    van Ijsseldijk, E A; Valstar, E R; Stoel, B C; Nelissen, R G H H; Reiber, J H C; Kaptein, B L

    2011-10-13

    Accurate in vivo measurements methods of wear in total knee arthroplasty are required for a timely detection of excessive wear and to assess new implant designs. Component separation measurements based on model-based Roentgen stereophotogrammetric analysis (RSA), in which 3-dimensional reconstruction methods are used, have shown promising results, yet the robustness of these measurements is unknown. In this study, the accuracy and robustness of this measurement for clinical usage was assessed. The validation experiments were conducted in an RSA setup with a phantom setup of a knee in a vertical orientation. 72 RSA images were created using different variables for knee orientations, two prosthesis types (fixed-bearing Duracon knee and fixed-bearing Triathlon knee) and accuracies of the reconstruction models. The measurement error was determined for absolute and relative measurements and the effect of knee positioning and true seperation distance was determined. The measurement method overestimated the separation distance with 0.1mm on average. The precision of the method was 0.10mm (2*SD) for the Duracon prosthesis and 0.20mm for the Triathlon prosthesis. A slight difference in error was found between the measurements with 0° and 10° anterior tilt. (difference=0.08mm, p=0.04). The accuracy of 0.1mm and precision of 0.2mm can be achieved for linear wear measurements based on model-based RSA, which is more than adequate for clinical applications. The measurement is robust in clinical settings. Although anterior tilt seems to influence the measurement, the size of this influence is low and clinically irrelevant. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Generating Modeling Data From Repeat-Dose Toxicity Reports

    PubMed Central

    López-Massaguer, Oriol; Pinto-Gil, Kevin; Sanz, Ferran; Amberg, Alexander; Anger, Lennart T; Stolte, Manuela; Ravagli, Carlo

    2018-01-01

    Abstract Over the past decades, pharmaceutical companies have conducted a large number of high-quality in vivo repeat-dose toxicity (RDT) studies for regulatory purposes. As part of the eTOX project, a high number of these studies have been compiled and integrated into a database. This valuable resource can be queried directly, but it can be further exploited to build predictive models. As the studies were originally conducted to investigate the properties of individual compounds, the experimental conditions across the studies are highly heterogeneous. Consequently, the original data required normalization/standardization, filtering, categorization and integration to make possible any data analysis (such as building predictive models). Additionally, the primary objectives of the RDT studies were to identify toxicological findings, most of which do not directly translate to in vivo endpoints. This article describes a method to extract datasets containing comparable toxicological properties for a series of compounds amenable for building predictive models. The proposed strategy starts with the normalization of the terms used within the original reports. Then, comparable datasets are extracted from the database by applying filters based on the experimental conditions. Finally, carefully selected profiles of toxicological findings are mapped to endpoints of interest, generating QSAR-like tables. In this work, we describe in detail the strategy and tools used for carrying out these transformations and illustrate its application in a data sample extracted from the eTOX database. The suitability of the resulting tables for developing hazard-predicting models was investigated by building proof-of-concept models for in vivo liver endpoints. PMID:29155963

  17. Formulation development of retrocyclin 1 analog RC-101 as an anti-HIV vaginal microbicide product.

    PubMed

    Sassi, A B; Cost, M R; Cole, A L; Cole, A M; Patton, D L; Gupta, P; Rohan, L C

    2011-05-01

    RC-101 is a synthetic microbicide analog of retrocyclin, which has shown in vitro activity against X4 and R5 HIV-1. In an effort to develop a safe and effective RC-101 vaginal microbicide product, we assessed safety in ex vivo macaque and human models and efficacy using in vitro and ex vivo models. A polyvinyl-alcohol vaginal film containing RC-101 (100 μg/film) was developed. Formulation assessment was conducted by evaluating disintegration, drug content, mechanical properties, and stability. Efficacy was evaluated by in vitro peripheral blood mononuclear cells (PBMC) assay and ex vivo human ectocervical tissue explant model. Ex vivo safety studies were conducted by exposing RC-101 to an excised monkey reproductive tract and excised human ectocervical tissue. RC-101 100 μg films were shown to be safe to human and monkey tissue and effective against HIV-1 in vitro and ex vivo in human ectocervical tissue. The 90% inhibitory concentration (IC90) for RC-101 films at 2,000 μg (IC90=57.5 μM) using an ex vivo model was 10-fold higher than the IC90 observed using an in vitro model (IC90=5.0 μM). RC-101 films were stable for 1 month at 25°C, with in vitro bioactivity maintained for up to 6 months. RC-101 was developed in a quick-dissolve film formulation that was shown to be safe in an ex vivo model and effective in in vitro and ex vivo models. RC-101 film formulations were shown to maintain bioactivity for a period of 6 months. Findings from the present study contribute to the development of a safe and effective topical microbicide product.

  18. Prediction of in vitro and in vivo oestrogen receptor activity using hierarchical clustering

    EPA Science Inventory

    In this study, hierarchical clustering classification models were developed to predict in vitro and in vivo oestrogen receptor (ER) activity. Classification models were developed for binding, agonist, and antagonist in vitro ER activity and for mouse in vivo uterotrophic ER bindi...

  19. Selective binding of lectins to normal and neoplastic urothelium in rat and mouse bladder carcinogenesis models.

    PubMed

    Zupančič, Daša; Kreft, Mateja Erdani; Romih, Rok

    2014-01-01

    Bladder cancer adjuvant intravesical therapy could be optimized by more selective targeting of neoplastic tissue via specific binding of lectins to plasma membrane carbohydrates. Our aim was to establish rat and mouse models of bladder carcinogenesis to investigate in vivo and ex vivo binding of selected lectins to the luminal surface of normal and neoplastic urothelium. Male rats and mice were treated with 0.05 % N-butyl-N-(4-hydroxybutyl)nitrosamine (BBN) in drinking water and used for ex vivo and in vivo lectin binding experiments. Urinary bladder samples were also used for paraffin embedding, scanning electron microscopy and immunofluorescence labelling of uroplakins. During carcinogenesis, the structure of the urinary bladder luminal surface changed from microridges to microvilli and ropy ridges and the expression of urothelial-specific glycoproteins uroplakins was decreased. Ex vivo and in vivo lectin binding experiments gave comparable results. Jacalin (lectin from Artocarpus integrifolia) exhibited the highest selectivity for neoplastic compared to normal urothelium of rats and mice. The binding of lectin from Amaranthus caudatus decreased in rat model and increased in mouse carcinogenesis model, indicating interspecies variations of plasma membrane glycosylation. Lectin from Datura stramonium showed higher affinity for neoplastic urothelium compared to the normal in rat and mouse model. The BBN-induced animal models of bladder carcinogenesis offer a promising approach for lectin binding experiments and further lectin-mediated targeted drug delivery research. Moreover, in vivo lectin binding experiments are comparable to ex vivo experiments, which should be considered when planning and optimizing future research.

  20. Quantification of Human Cortical Bone Bound and Free Water in Vivo with Ultrashort Echo Time MR Imaging: A Model-based Approach.

    PubMed

    Abbasi-Rad, Shahrokh; Saligheh Rad, Hamidreza

    2017-06-01

    Purpose To quantify free and bound water components of cortical bone with a model-based numeric approach with use of ultrashort echo time (UTE) magnetic resonance (MR) imaging in vivo in order to introduce a new predictor for age-related deterioration of cortical bone structure. Materials and Methods Human studies were compliant with HIPAA and approved by the institutional review board. Dual-repetition time three-dimensional hybrid-radial UTE imaging was performed, followed by the application of postprocessing algorithms, to quantify free and bound water parameters (concentration [ρ] and longitudinal relaxation time [T1]) of human cortical bone in vivo. The postprocessing algorithms included the decomposition of bulk equations into free- and bound-associated equations and solving resulted inverse problem by using evolutionary strategy methods. To test the validity of the introduced biomarker, it was measured in 40 healthy women by using the proposed method, and associations among parameters were evaluated with the Pearson correlation coefficient. Results The mean free water concentration, bound water concentration, free water T1, and bound water T1 in the recruited population were 5.9%, 19.6%, 306.79 msec, and 162.47 msec, respectively. All reported values were in good agreement with those in the literature. Cortical bone free water T1 (R 2 = 0.72) and cortical bone free water concentration (R 2 = 0.62) showed strong positive correlations with age. Conclusion The cortical bone free water concentration and free water T1 derived with UTE imaging are good predictors of age-related deterioration of cortical bone structure and are potentially superior to previously introduced measures such as bone water concentration and suppression ratio. © RSNA, 2017.

  1. In Vivo Determination of Mitochondrial Function Using Luciferase-Expressing Caenorhabditis elegans: Contribution of Oxidative Phosphorylation, Glycolysis, and Fatty Acid Oxidation to Toxicant-Induced Dysfunction.

    PubMed

    Luz, Anthony L; Lagido, Cristina; Hirschey, Matthew D; Meyer, Joel N

    2016-08-01

    Mitochondria are a target of many drugs and environmental toxicants; however, how toxicant-induced mitochondrial dysfunction contributes to the progression of human disease remains poorly understood. To address this issue, in vivo assays capable of rapidly assessing mitochondrial function need to be developed. Here, using the model organism Caenorhabditis elegans, we describe how to rapidly assess the in vivo role of the electron transport chain, glycolysis, or fatty acid oxidation in energy metabolism following toxicant exposure, using a luciferase-expressing ATP reporter strain. Alterations in mitochondrial function subsequent to toxicant exposure are detected by depleting steady-state ATP levels with inhibitors of the mitochondrial electron transport chain, glycolysis, or fatty acid oxidation. Differential changes in ATP following short-term inhibitor exposure indicate toxicant-induced alterations at the site of inhibition. Because a microplate reader is the only major piece of equipment required, this is a highly accessible method for studying toxicant-induced mitochondrial dysfunction in vivo. © 2016 by John Wiley & Sons, Inc. Copyright © 2016 John Wiley & Sons, Inc.

  2. 3D artificial bones for bone repair prepared by computed tomography-guided fused deposition modeling for bone repair.

    PubMed

    Xu, Ning; Ye, Xiaojian; Wei, Daixu; Zhong, Jian; Chen, Yuyun; Xu, Guohua; He, Dannong

    2014-09-10

    The medical community has expressed significant interest in the development of new types of artificial bones that mimic natural bones. In this study, computed tomography (CT)-guided fused deposition modeling (FDM) was employed to fabricate polycaprolactone (PCL)/hydroxyapatite (HA) and PCL 3D artificial bones to mimic natural goat femurs. The in vitro mechanical properties, in vitro cell biocompatibility, and in vivo performance of the artificial bones in a long load-bearing goat femur bone segmental defect model were studied. All of the results indicate that CT-guided FDM is a simple, convenient, relatively low-cost method that is suitable for fabricating natural bonelike artificial bones. Moreover, PCL/HA 3D artificial bones prepared by CT-guided FDM have more close mechanics to natural bone, good in vitro cell biocompatibility, biodegradation ability, and appropriate in vivo new bone formation ability. Therefore, PCL/HA 3D artificial bones could be potentially be of use in the treatment of patients with clinical bone defects.

  3. Brain Aggregates: An Effective In Vitro Cell Culture System Modeling Neurodegenerative Diseases.

    PubMed

    Ahn, Misol; Kalume, Franck; Pitstick, Rose; Oehler, Abby; Carlson, George; DeArmond, Stephen J

    2016-03-01

    Drug discovery for neurodegenerative diseases is particularly challenging because of the discrepancies in drug effects between in vitro and in vivo studies. These discrepancies occur in part because current cell culture systems used for drug screening have many limitations. First, few cell culture systems accurately model human aging or neurodegenerative diseases. Second, drug efficacy may differ between dividing and stationary cells, the latter resembling nondividing neurons in the CNS. Brain aggregates (BrnAggs) derived from embryonic day 15 gestation mouse embryos may represent neuropathogenic processes in prion disease and reflect in vivo drug efficacy. Here, we report a new method for the production of BrnAggs suitable for drug screening and suggest that BrnAggs can model additional neurological diseases such as tauopathies. We also report a functional assay with BrnAggs by measuring electrophysiological activities. Our data suggest that BrnAggs could serve as an effective in vitro cell culture system for drug discovery for neurodegenerative diseases. © 2016 American Association of Neuropathologists, Inc. All rights reserved.

  4. Micro-tattoo guided OCT imaging of site specific inflammation

    NASA Astrophysics Data System (ADS)

    Phillips, Kevin G.; Choudhury, Niloy; Samatham, Ravikant V.; Singh, Harvinder; Jacques, Steven L.

    2010-02-01

    Epithelial biologists studying human skin diseases such as cancer formation and psoriasis commonly utilize mouse models to characterize the interplay among cells and intracellular signal transduction pathways that result in programmed changes in gene expression and cellular behaviors. The information obtained from animal models is useful only when phenotypic presentations of disease recapitulate those observed in humans. Excision of tissues followed by histochemical analysis is currently the primary means of establishing the morphological presentation. Non invasive imaging of animal models provides an alternate means to characterize tissue morphology associated with the disease of interest in vivo. While useful, the ability to perform in vivo imaging at different time points in the same tissue location has been a challenge. This information is key to understanding site specific changes as the imaged tissue can now be extracted and analyzed for mRNA expression. We present a method employing a micro-tattoo to guide optical coherence tomography (OCT) imaging of ultraviolet induced inflammation over time in the same tissue locations.

  5. Association Between Genetic Variation in FOXO3 and Reductions in Inflammation and Disease Activity in Inflammatory Polyarthritis

    PubMed Central

    Viatte, Sebastien; Lee, James C.; Fu, Bo; Espéli, Marion; Lunt, Mark; De Wolf, Jack N. E.; Wheeler, Lily; Reynolds, John A.; Castelino, Madhura; Symmons, Deborah P. M.; Lyons, Paul A.

    2016-01-01

    Objective Genetic variation in FOXO3 (tagged by rs12212067) has been associated with a milder course of rheumatoid arthritis (RA) and shown to limit monocyte‐driven inflammation through a transforming growth factor β1–dependent pathway. This genetic association, however, has not been consistently observed in other RA cohorts. We sought to clarify the contribution of FOXO3 to prognosis in RA by combining detailed analysis of nonradiographic disease severity measures with an in vivo model of arthritis. Methods Collagen‐induced arthritis, the most commonly used mouse model of RA, was used to assess how Foxo3 contributes to arthritis severity. Using clinical, serologic, and biochemical methods, the arthritis that developed in mice carrying a loss‐of‐function mutation in Foxo3 was compared with that which occurred in littermate controls. The association of rs12212067 with nonradiographic measures of RA severity, including the C‐reactive protein level, the swollen joint count, the tender joint count, the Disease Activity Score in 28 joints, and the Health Assessment Questionnaire score, were modeled longitudinally in a large prospective cohort of patients with early RA. Results Loss of Foxo3 function resulted in more severe arthritis in vivo (both clinically and histologically) and was associated with higher titers of anticollagen antibodies and interleukin‐6 in the blood. Similarly, rs12212067 (a single‐nucleotide polymorphism that increases FOXO3 transcription) was associated with reduced inflammation, both biochemically and clinically, and with lower RA activity scores. Conclusion Consistent with its known role in restraining inflammatory responses, FOXO3 limits the severity of in vivo arthritis and, through genetic variation that increases its transcription, is associated with reduced inflammation and disease activity in RA patients, effects that result in less radiographic damage. PMID:27214848

  6. Cortical Surface Registration for Image-Guided Neurosurgery Using Laser-Range Scanning

    PubMed Central

    Sinha, Tuhin K.; Cash, David M.; Galloway, Robert L.; Weil, Robert J.

    2013-01-01

    In this paper, a method of acquiring intraoperative data using a laser range scanner (LRS) is presented within the context of model-updated image-guided surgery. Registering textured point clouds generated by the LRS to tomographic data is explored using established point-based and surface techniques as well as a novel method that incorporates geometry and intensity information via mutual information (SurfaceMI). Phantom registration studies were performed to examine accuracy and robustness for each framework. In addition, an in vivo registration is performed to demonstrate feasibility of the data acquisition system in the operating room. Results indicate that SurfaceMI performed better in many cases than point-based (PBR) and iterative closest point (ICP) methods for registration of textured point clouds. Mean target registration error (TRE) for simulated deep tissue targets in a phantom were 1.0 ± 0.2, 2.0 ± 0.3, and 1.2 ± 0.3 mm for PBR, ICP, and SurfaceMI, respectively. With regard to in vivo registration, the mean TRE of vessel contour points for each framework was 1.9 ± 1.0, 0 9 ± 0.6, and 1.3 ± 0.5 for PBR, ICP, and SurfaceMI, respectively. The methods discussed in this paper in conjunction with the quantitative data provide impetus for using LRS technology within the model-updated image-guided surgery framework. PMID:12906252

  7. Systematic wavelength selection for improved multivariate spectral analysis

    DOEpatents

    Thomas, Edward V.; Robinson, Mark R.; Haaland, David M.

    1995-01-01

    Methods and apparatus for determining in a biological material one or more unknown values of at least one known characteristic (e.g. the concentration of an analyte such as glucose in blood or the concentration of one or more blood gas parameters) with a model based on a set of samples with known values of the known characteristics and a multivariate algorithm using several wavelength subsets. The method includes selecting multiple wavelength subsets, from the electromagnetic spectral region appropriate for determining the known characteristic, for use by an algorithm wherein the selection of wavelength subsets improves the model's fitness of the determination for the unknown values of the known characteristic. The selection process utilizes multivariate search methods that select both predictive and synergistic wavelengths within the range of wavelengths utilized. The fitness of the wavelength subsets is determined by the fitness function F=.function.(cost, performance). The method includes the steps of: (1) using one or more applications of a genetic algorithm to produce one or more count spectra, with multiple count spectra then combined to produce a combined count spectrum; (2) smoothing the count spectrum; (3) selecting a threshold count from a count spectrum to select these wavelength subsets which optimize the fitness function; and (4) eliminating a portion of the selected wavelength subsets. The determination of the unknown values can be made: (1) noninvasively and in vivo; (2) invasively and in vivo; or (3) in vitro.

  8. High-resolution detection of 13C multiplets from the conscious mouse brain by ex vivo NMR spectroscopy

    PubMed Central

    Marin-Valencia, Isaac; Good, Levi B.; Ma, Qian; Jeffrey, F. Mark; Malloy, Craig R.; Pascual, Juan M.

    2011-01-01

    Glucose readily supplies the brain with the majority of carbon needed to sustain neurotransmitter production and utilization., The rate of brain glucose metabolism can be computed using 13C nuclear magnetic resonance (NMR) spectroscopy by detecting changes in 13C contents of products generated by cerebral metabolism. As previously observed, scalar coupling between adjacent 13C carbons (multiplets) can provide additional information to 13C contents for the computation of metabolic rates. Most NMR studies have been conducted in large animals (often under anesthesia) because the mass of the target organ is a limiting factor for NMR. Yet, despite the challengingly small size of the mouse brain, NMR studies are highly desirable because the mouse constitutes a common animal model for human neurological disorders. We have developed a method for the ex vivo resolution of NMR multiplets arising from the brain of an awake mouse after the infusion of [1,6-13C2]glucose. NMR spectra obtained by this method display favorable signal-to-noise ratios. With this protocol, the 13C multiplets of glutamate, glutamine, GABA and aspartate achieved steady state after 150 min. The method enables the accurate resolution of multiplets over time in the awake mouse brain. We anticipate that this method can be broadly applicable to compute brain fluxes in normal and transgenic mouse models of neurological disorders. PMID:21946227

  9. Surface-to-volume ratio mapping of tumor microstructure using oscillating gradient diffusion weighted imaging

    PubMed Central

    Reynaud, Olivier; Winters, Kerryanne Veronica; Hoang, Dung Minh; Wadghiri, Youssef Zaim; Novikov, Dmitry S; Kim, Sungheon Gene

    2015-01-01

    Purpose To disentangle the free diffusivity (D0) and cellular membrane restrictions, via their surface-to-volume ratio (S/V), using the frequency-dependence of the diffusion coefficient D(ω), measured in brain tumors in the short diffusion-time regime using oscillating gradients (OGSE). Methods In vivo and ex vivo OGSE experiments were performed on mice bearing the GL261 murine glioma model (n=10) to identify the relevant time/frequency (t/ω) domain where D(ω) linearly decreases with ω−1/2. Parametric maps (S/V, D0) are compared to conventional DWI metrics. The impact of frequency range and temperature (20°C vs. 37°C) on S/V and D0 is investigated ex vivo. Results The validity of the short diffusion-time regime is demonstrated in vivo and ex vivo. Ex vivo measurements confirm that the purely geometric restrictions embodied in S/V are independent from temperature and frequency range, while the temperature dependence of the free diffusivity D0 is similar to that of pure water. Conclusion Our results suggest that D(ω) in the short diffusion-time regime can be used to uncouple the purely geometric restriction effect, such as S/V, from the intrinsic medium diffusivity properties, and provides a non-empirical and objective way to interpret frequency/time-dependent diffusion changes in tumors in terms of objective biophysical tissue parameters. PMID:26207354

  10. In vivo antimicrobial activity of silver nanoparticles produced via a green chemistry synthesis using Acacia rigidula as a reducing and capping agent.

    PubMed

    Escárcega-González, Carlos Enrique; Garza-Cervantes, J A; Vázquez-Rodríguez, A; Montelongo-Peralta, Liliana Zulem; Treviño-González, M T; Díaz Barriga Castro, E; Saucedo-Salazar, E M; Chávez Morales, R M; Regalado Soto, D I; Treviño González, F M; Carrazco Rosales, J L; Cruz, Rocío Villalobos; Morones-Ramírez, José Rubén

    2018-01-01

    One of the main issues in the medical field and clinical practice is the development of novel and effective treatments against infections caused by antibiotic-resistant bacteria. One avenue that has been approached to develop effective antimicrobials is the use of silver nanoparticles (Ag-NPs), since they have been found to exhibit an efficient and wide spectrum of antimicrobial properties. Among the main drawbacks of using Ag-NPs are their potential cytotoxicity against eukaryotic cells and the latent environmental toxicity of their synthesis methods. Therefore, diverse green synthesis methods, which involve the use of environmentally friendly plant extracts as reductive and capping agents, have become attractive to synthesize Ag-NPs that exhibit antimicrobial effects against resistant bacteria at concentrations below toxicity thresholds for eukaryotic cells. In this study, we report a green one-pot synthesis method that uses Acacia rigidula extract as a reducing and capping agent, to produce Ag-NPs with applications as therapeutic agents to treat infections in vivo. The Ag-NPs were characterized using transmission electron microscopy (TEM), high-resolution TEM, selected area electron diffraction, energy-dispersive spectroscopy, ultraviolet-visible, and Fourier transform infrared. We show that Ag-NPs are spherical with a narrow size distribution. The Ag-NPs show antimicrobial activities in vitro against Gram-negative ( Escherichia coli , Pseudomonas aeruginosa , and a clinical multidrug-resistant strain of P. aeruginosa ) and Gram-positive ( Bacillus subtilis ) bacteria. Moreover, antimicrobial effects of the Ag-NPs, against a resistant P. aeruginosa clinical strain, were tested in a murine skin infection model. The results demonstrate that the Ag-NPs reported in this work are capable of eradicating pathogenic resistant bacteria in an infection in vivo. In addition, skin, liver, and kidney damage profiles were monitored in the murine infection model, and the results demonstrate that Ag-NPs can be used safely as therapeutic agents in animal models. Together, these results suggest the potential use of Ag-NPs, synthesized by green chemistry methods, as therapeutic agents against infections caused by resistant and nonresistant strains.

  11. Development and characterization of an ex-vivo brain slice culture model of chronic wasting disease

    USDA-ARS?s Scientific Manuscript database

    Prion diseases have long incubation times in vivo, therefore, modeling the diseases ex-vivo will advance the development of rationale-based therapeutic strategies. An organotypic slice culture assay (POSCA) was recently developed for scrapie prions by inoculating mouse cerebellar brain slices with R...

  12. Modifying the affective behavior of preschoolers with autism using in-vivo or video modeling and reinforcement contingencies.

    PubMed

    Gena, Angeliki; Couloura, Sophia; Kymissis, Effie

    2005-10-01

    The purpose of this study was to modify the affective behavior of three preschoolers with autism in home settings and in the context of play activities, and to compare the effects of video modeling to the effects of in-vivo modeling in teaching these children contextually appropriate affective responses. A multiple-baseline design across subjects, with a return to baseline condition, was used to assess the effects of treatment that consisted of reinforcement, video modeling, in-vivo modeling, and prompting. During training trials, reinforcement in the form of verbal praise and tokens was delivered contingent upon appropriate affective responding. Error correction procedures differed for each treatment condition. In the in-vivo modeling condition, the therapist used modeling and verbal prompting. In the video modeling condition, video segments of a peer modeling the correct response and verbal prompting by the therapist were used as corrective procedures. Participants received treatment in three categories of affective behavior--sympathy, appreciation, and disapproval--and were presented with a total of 140 different scenarios. The study demonstrated that both treatments--video modeling and in-vivo modeling--systematically increased appropriate affective responding in all response categories for the three participants. Additionally, treatment effects generalized across responses to untrained scenarios, the child's mother, new therapists, and time.

  13. Combination of Estrogen and Immunosuppressive Agents to Establish a Mouse Model of Candidiasis with Concurrent Oral and Vaginal Mucosal Infection.

    PubMed

    Wang, Le; Wang, Chong; Mei, Huan; Shen, Yongnian; Lv, Guixia; Zeng, Rong; Zhan, Ping; Li, Dongmei; Liu, Weida

    2016-02-01

    Mouse model is an appropriate tool for pathogenic determination and study of host defenses during the fungal infection. Here, we established a mouse model of candidiasis with concurrent oral and vaginal mucosal infection. Two C. albicans strains sourced from clinical candidemia (SC5314) and mucosal infection (ATCC62342) were tested in ICR mice. The different combinational panels covering estrogen and immunosuppressive agents, cortisone, prednisolone and cyclophosphamide were used for concurrent oral and vaginal candidiasis establishment. Prednisolone in combination with estrogen proved an optimal mode for concurrent mucosal infection establishment. The model maintained for 1 week with fungal burden reached at least 10(5) cfu/g of tissue. This mouse model was evaluated by in vivo pharmacodynamics of fluconazole and host mucosal immunity of IL-17 and IL-23. Mice infected by SC5314 were cured by fluconazole. An increase in IL-23 in both oral and vaginal homogenates was observed after infection, while IL-17 only had a prominent elevation in oral tissue. This model could properly mimic complicated clinical conditions and provides a valuable means for antifungal assay in vivo and may also provide a useful method for the evaluation of host-fungal interactions.

  14. Three-Dimensional Human Tissue Models That Incorporate Diabetic Foot Ulcer-Derived Fibroblasts Mimic In Vivo Features of Chronic Wounds

    PubMed Central

    Maione, Anna G.; Brudno, Yevgeny; Stojadinovic, Olivera; Park, Lara K.; Smith, Avi; Tellechea, Ana; Leal, Ermelindo C.; Kearney, Cathal J.; Veves, Aristidis; Tomic-Canic, Marjana; Mooney, David J.

    2015-01-01

    Diabetic foot ulcers (DFU) are a major, debilitating complication of diabetes mellitus. Unfortunately, many DFUs are refractory to existing treatments and frequently lead to amputation. The development of more effective therapies has been hampered by the lack of predictive in vitro methods to investigate the mechanisms underlying impaired healing. To address this need for realistic wound-healing models, we established patient-derived fibroblasts from DFUs and site-matched controls and used them to construct three-dimensional (3D) models of chronic wound healing. Incorporation of DFU-derived fibroblasts into these models accurately recapitulated the following key aspects of chronic ulcers: reduced stimulation of angiogenesis, increased keratinocyte proliferation, decreased re-epithelialization, and impaired extracellular matrix deposition. In addition to reflecting clinical attributes of DFUs, the wound-healing potential of DFU fibroblasts demonstrated in this suite of models correlated with in vivo wound closure in mice. Thus, the reported panel of 3D DFU models provides a more biologically relevant platform for elucidating the cell–cell and cell–matrix-related mechanisms responsible for chronic wound pathogenesis and may improve translation of in vitro findings into efficacious clinical applications. PMID:25343343

  15. Intra-patient variability of thromboelastographic parameters following in vivo and ex vivo administration of recombinant activated factor VII in haemophilia patients. A multi-centre, randomised trial.

    PubMed

    Kenet, G; Stenmo, C B; Blemings, A; Wegert, W; Goudemand, J; Krause, M; Schramm, W; Kirchmaier, C; Martinowitz, U

    2010-02-01

    Thromboelastography methods have been used to predict or monitor treatment of haemophilia patients with recombinant activated factor VII (rFVIIa). However, neither of the two thromboelastographic methods (ROTEM and TEG) has as yet been validated. This multi-centre, randomised trial compared both methods in terms of intra- and inter- patient variability following in vivo and ex vivo rFVIIa administration to haemophilia A and B patients with and without inhibitors. Patients ((3)16 years old) received the same intravenous rFVIIa dose (45, 90 or 180 microg/kg) twice, 1-12 weeks apart. Blood samples were collected pre-dose and 15, 60, 120 and 240 minutes post-dose for ROTEM and TEG analysis. Pre-dose samples were also spiked ex vivo with rFVIIa (0.6, 1.2 or 2.4 microg/ml), to correspond to the three in vivo doses. Twenty-six haemophilia A and four haemophilia B patients were enrolled. A significant treatment effect was observed with in vivo rFVIIa (p<0.05) with more pronounced effects in inhibitor (n=14) versus non-inhibitor (n=16) patients. There was a strong positive correlation between ROTEM and TEG parameters. Intra- and inter-patient variation was large for all thromboelastography parameters at all time points and rFVIIa doses. Intra-patient variation was generally lower for non-inhibitor than inhibitor patients, and lower following ex vivo spiking versus in vivo rFVIIa administration. In conclusion, there was a clear effect of rFVIIa on all thromboelastography parameters, but the large intra- and inter-patient variability following in vivo rFVIIa administration renders the use of our method unsuitable for dose-response prediction for haemophilia patients in the clinical setting.

  16. Intraoperative on-the-fly organ-mosaicking for laparoscopic surgery

    PubMed Central

    Reichard, Daniel; Bodenstedt, Sebastian; Suwelack, Stefan; Mayer, Benjamin; Preukschas, Anas; Wagner, Martin; Kenngott, Hannes; Müller-Stich, Beat; Dillmann, Rüdiger; Speidel, Stefanie

    2015-01-01

    Abstract. The goal of computer-assisted surgery is to provide the surgeon with guidance during an intervention, e.g., using augmented reality. To display preoperative data, soft tissue deformations that occur during surgery have to be taken into consideration. Laparoscopic sensors, such as stereo endoscopes, can be used to create a three-dimensional reconstruction of stereo frames for registration. Due to the small field of view and the homogeneous structure of tissue, reconstructing just one frame, in general, will not provide enough detail to register preoperative data, since every frame only contains a part of an organ surface. A correct assignment to the preoperative model is possible only if the patch geometry can be unambiguously matched to a part of the preoperative surface. We propose and evaluate a system that combines multiple smaller reconstructions from different viewpoints to segment and reconstruct a large model of an organ. Using graphics processing unit-based methods, we achieved four frames per second. We evaluated the system with in silico, phantom, ex vivo, and in vivo (porcine) data, using different methods for estimating the camera pose (optical tracking, iterative closest point, and a combination). The results indicate that the proposed method is promising for on-the-fly organ reconstruction and registration. PMID:26693166

  17. Comparison between reflectance confocal microscopy and two-photon microscopy in early detection of cutaneous radiation injury in a mouse model in-vivo.

    PubMed

    Jang, Won Hyuk; Kwon, Soonjae; Shim, Sehwan; Jang, Won-Suk; Myung, Jae Kyung; Yang, Sejung; Park, Sunhoo; Kim, Ki Hean

    2018-05-12

    Cutaneous radiation injury (CRI) is a skin injury caused by high dose exposure of ionizing radiation (IR). For proper treatment, early detection of CRI before clinical symptoms is important. Optical microscopic techniques such as reflectance confocal microscopy (RCM) and two-photon microscopy (TPM) have been tested as the early diagnosis method by detecting cellular changes. In this study, RCM and TPM were compared in the detection of cellular changes caused by CRI in an in-vivo mouse model. CRI was induced on the mouse hindlimb skin with various IR doses and the injured skin regions were imaged longitudinally by both modalities until the onset of clinical symptoms. Both RCM and TPM detected the changes of epidermal cells and sebaceous glands before clinical symptoms in different optical contrasts. RCM detected changes of cell morphology and scattering property based on light reflection. TPM detected detail changes of cellular structures based on autofluorescence of cells. Since both RCM and TPM were sensitive to the early-stage CRI by using different contrasts, the optimal method for clinical CRI diagnosis could be either individual methods or their combination. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  18. Comparison of amyloid plaque contrast generated by T2-, T2*-, and susceptibility-weighted imaging methods in transgenic mouse models of Alzheimer’s disease

    PubMed Central

    Chamberlain, Ryan; Reyes, Denise; Curran, Geoffrey L.; Marjanska, Malgorzata; Wengenack, Thomas M.; Poduslo, Joseph F.; Garwood, Michael; Jack, Clifford R.

    2009-01-01

    One of the hallmark pathologies of Alzheimer’s disease (AD) is amyloid plaque deposition. Plaques appear hypointense on T2- and T2*-weighted MR images probably due to the presence of endogenous iron, but no quantitative comparison of various imaging techniques has been reported. We estimated the T1, T2, T2*, and proton density values of cortical plaques and normal cortical tissue and analyzed the plaque contrast generated by a collection of T2-, T2*-, and susceptibility-weighted imaging (SWI) methods in ex vivo transgenic mouse specimens. The proton density and T1 values were similar for both cortical plaques and normal cortical tissue. The T2 and T2* values were similar in cortical plaques, which indicates that the iron content of cortical plaques may not be as large as previously thought. Ex vivo plaque contrast was increased compared to a previously reported spin echo sequence by summing multiple echoes and by performing SWI; however, gradient echo and susceptibility weighted imaging was found to be impractical for in vivo imaging due to susceptibility interface-related signal loss in the cortex. PMID:19253386

  19. Time-controlled release pseudoephedrine tablets: bioavailability and in vitro/in vivo correlations.

    PubMed

    Halsas, M; Penttinen, T; Veski, P; Jürjenson, H; Marvola, M

    2001-09-01

    In chronopharmacotherapy, circadian changes in disease symptoms are taken into account. Press-coated, time-controlled release tablets containing pseudoephedrine hydrochloride as a model drug have been formulated and the suitability of this highly soluble drug in relation to the new drug delivery system was evaluated. Hydroxypropylmethylcellulose was used in the coat of the tablet to adjust drug release. If such a formulation was administered in the evening it would have maximal effect in the early morning, and would be useful for the treatment of nocturnal symptoms. Two cross-over, single-dose bioavailability studies were carried out on eight healthy volunteers. A dissolution test method was developed to establish level A and level C in vitro/in vivo correlation for four formulations. With a low viscosity grade of polymer, peak concentrations were achieved after five hours. The drug was absorbed much more slowly from tablets containing a high viscosity grade polymer, with a plasma peak at ten hours. For further development of the drug delivery system described, a dissolution test method at pH 7.2 at a rotation speed of 150 min-1 is recommended on the basis of level A in vitro/in vivo correlation.

  20. Staging Liver Fibrosis with Statistical Observers

    NASA Astrophysics Data System (ADS)

    Brand, Jonathan Frieman

    Chronic liver disease is a worldwide health problem, and hepatic fibrosis (HF) is one of the hallmarks of the disease. Pathology diagnosis of HF is based on textural change in the liver as a lobular collagen network that develops within portal triads. The scale of collagen lobules is characteristically on order of 1mm, which close to the resolution limit of in vivo Gd-enhanced MRI. In this work the methods to collect training and testing images for a Hotelling observer are covered. An observer based on local texture analysis is trained and tested using wet-tissue phantoms. The technique is used to optimize the MRI sequence based on task performance. The final method developed is a two stage model observer to classify fibrotic and healthy tissue in both phantoms and in vivo MRI images. The first stage observer tests for the presence of local texture. Test statistics from the first observer are used to train the second stage observer to globally sample the local observer results. A decision of the disease class is made for an entire MRI image slice using test statistics collected from the second observer. The techniques are tested on wet-tissue phantoms and in vivo clinical patient data.

Top