Sample records for vo2 slow component

  1. The slow component of O(2) uptake is not accompanied by changes in muscle EMG during repeated bouts of heavy exercise in humans.

    PubMed

    Scheuermann, B W; Hoelting, B D; Noble, M L; Barstow, T J

    2001-02-15

    1. We hypothesized that either the recruitment of additional muscle motor units and/or the progressive recruitment of less efficient fast-twitch muscle fibres was the predominant contributor to the additional oxygen uptake (VO2) observed during heavy exercise. Using surface electromyographic (EMG) techniques, we compared the VO2 response with the integrated EMG (iEMG) and mean power frequency (MPF) response of the vastus lateralis with the VO2 response during repeated bouts of moderate (below the lactate threshold, < LT) and heavy (above the lactate threshold, > LT) intensity cycle ergometer exercise. 2. Seven male subjects (age 29 +/- 7 years, mean +/- S.D.) performed three transitions to a work rate (WR) corresponding to 90 % LT and two transitions to a work rate that would elicit a VO2 corresponding to 50 % of the difference between peak VO2 and the LT (i.e. Delta50 %, > LT1 and > LT2). 3. The VO2 slow component was significantly reduced by prior heavy intensity exercise (> LT1, 410 +/- 196 ml min(-1); > LT2, 230 +/- 191 ml min-1). The time constant (tau), amplitude (A) and gain (DeltaVO2/DeltaWR) of the primary VO2 response (phase II) were not affected by prior heavy exercise when a three-component, exponential model was used to describe the V2 response. 4. Integrated EMG and MPF remained relatively constant and at the same level throughout both > LT1 and > LT2 exercise and therefore were not associated with the VO2 slow component. 5. These data are consistent with the view that the increased O2 cost (i.e. VO2 slow component) associated with performing heavy exercise is coupled with a progressive increase in ATP requirements of the already recruited motor units rather than to changes in the recruitment pattern of slow versus fast-twitch motor units. Further, the lack of speeding of the kinetics of the primary VO2 component with prior heavy exercise, thought to represent the initial muscle VO2 response, are inconsistent with O2 delivery being the limiting factor in V > O2 kinetics during heavy exercise.

  2. A comparison of modelling techniques used to characterise oxygen uptake kinetics during the on-transient of exercise.

    PubMed

    Bell, C; Paterson, D H; Kowalchuk, J M; Padilla, J; Cunningham, D A

    2001-09-01

    We compared estimates for the phase 2 time constant (tau) of oxygen uptake (VO2) during moderate- and heavy-intensity exercise, and the slow component of VO2 during heavy-intensity exercise using previously published exponential models. Estimates for tau and the slow component were different (P < 0.05) among models. For moderate-intensity exercise, a two-component exponential model, or a mono-exponential model fitted from 20 s to 3 min were best. For heavy-intensity exercise, a three-component model fitted throughout the entire 6 min bout of exercise, or a two-component model fitted from 20 s were best. When the time delays for the two- and three-component models were equal the best statistical fit was obtained; however, this model produced an inappropriately low DeltaVO2/DeltaWR (WR, work rate) for the projected phase 2 steady state, and the estimate of phase 2 tau was shortened compared with other models. The slow component was quantified as the difference between VO2 at end-exercise (6 min) and at 3 min (DeltaVO2 (6-3 min)); 259 ml x min(-1)), and also using the phase 3 amplitude terms (truncated to end-exercise) from exponential fits (409-833 ml x min(-1)). Onset of the slow component was identified by the phase 3 time delay parameter as being of delayed onset approximately 2 min (vs. arbitrary 3 min). Using this delay DeltaVO2 (6-2 min) was approximately 400 ml x min(-1). Use of valid consistent methods to estimate tau and the slow component in exercise are needed to advance physiological understanding.

  3. Muscle glycogen reduction in man: relationship between surface EMG activity and oxygen uptake kinetics during heavy exercise.

    PubMed

    Osborne, Mark A; Schneider, Donald A

    2006-01-01

    The purpose of this study was to determine whether muscle glycogen reduction prior to exercise would alter muscle fibre recruitment pattern and change either on-transient O2 uptake (VO2) kinetics or the VO2 slow component. Eight recreational cyclists (VO2peak, 55.6 +/- 1.3 ml kg (-1) min(-1)) were studied during 8 min of heavy constant-load cycling performed under control conditions (CON) and under conditions of reduced type I muscle glycogen content (GR). VO2 was measured breath-by-breath for the determination of VO2 kinetics using a double-exponential model with independent time delays. VO2 was higher in the GR trial compared to the CON trial as a result of augmented phase I and II amplitudes, with no difference between trials in the phase II time constant or the magnitude of the slow component. The mean power frequency (MPF) of electromyography activity for the vastus medialis increased over time during both trials, with a greater rate of increase observed in the GR trial compared to the CON trial. The results suggest that the recruitment of additional type II motor units contributed to the slow component in both trials. An increase in fat metabolism and augmented type II motor unit recruitment contributed to the higher VO2 in the GR trial. However, the greater rate of increase in the recruitment of type II motor units in the GR trial may not have been of sufficient magnitude to further elevate the slow component when VO2 was already high and approaching VO2peak .

  4. Effect of pedal rate on primary and slow-component oxygen uptake responses during heavy-cycle exercise.

    PubMed

    Pringle, Jamie S M; Doust, Jonathan H; Carter, Helen; Tolfrey, Keith; Jones, Andrew M

    2003-04-01

    We hypothesized that a higher pedal rate (assumed to result in a greater proportional contribution of type II motor units) would be associated with an increased amplitude of the O(2) uptake (Vo(2)) slow component during heavy-cycle exercise. Ten subjects (mean +/- SD, age 26 +/- 4 yr, body mass 71.5 +/- 7.9 kg) completed a series of square-wave transitions to heavy exercise at pedal rates of 35, 75, and 115 rpm. The exercise power output was set at 50% of the difference between the pedal rate-specific ventilatory threshold and peak Vo(2), and the baseline power output was adjusted to account for differences in the O(2) cost of unloaded pedaling. The gain of the Vo(2) primary component was significantly higher at 35 rpm compared with 75 and 115 rpm (mean +/- SE, 10.6 +/- 0.3, 9.5 +/- 0.2, and 8.9 +/- 0.4 ml. min(-1). W(-1), respectively; P < 0.05). The amplitude of the Vo(2) slow component was significantly greater at 115 rpm (328 +/- 29 ml/min) compared with 35 rpm (109 +/- 30 ml/min) and 75 rpm (202 +/- 38 ml/min) (P < 0.05). There were no significant differences in the time constants or time delays associated with the primary and slow components across the pedal rates. The change in blood lactate concentration was significantly greater at 115 rpm (3.7 +/- 0.2 mM) and 75 rpm (2.8 +/- 0.3 mM) compared with 35 rpm (1.7 +/- 0.4 mM) (P < 0.05). These data indicate that pedal rate influences Vo(2) kinetics during heavy exercise at the same relative intensity, presumably by altering motor unit recruitment patterns.

  5. Exertional oxygen uptake kinetics: a stamen of stamina?

    PubMed

    Whipp, Brian J; Rossiter, H B; Ward, S A

    2002-04-01

    The fundamental pulmonary O(2) uptake (.VO(2)) response to moderate, constant-load exercise can be characterized as (d.VO(2)/dt)(tau)+Delta.VO(2) (t)=Delta.VO(2SS) where Delta.VO(2SS) is the steady-state response, and tau is the time constant, with the .VO(2) kinetics reflecting intramuscular O(2) uptake (.QO(2)) kinetics, to within 10%. The role of phosphocreatine (PCr) turnover in .QO(2) control can be explored using (31)P-MR spectroscopy, simultaneously with .VO(2). Although tau.VO(2) and tauPCr vary widely among subjects (approx. 20-65 s), they are not significantly different from each other, either at the on- or off-transient. A caveat to interpreting the "well-fit" exponential is that numerous units of similar Delta.VO(2SS) but with a wide tau distribution can also yield a .VO(2) response with an apparent single tau. This tau is, significantly, inversely correlated with lactate threshold and .VO(2max)(but is poorly predictive; a frail stamen, therefore), consistent with tau not characterizing a compartment with uniform kinetics. At higher intensities, the fundamental kinetics become supplemented with a slowly-developing phase, setting .VO(2)on a trajectory towards maximum .VO(2). This slow component is also demonstrable in Delta[PCr]: the decreased efficiency thereby reflecting a predominantly high phosphate-cost of force production rather than a high O(2)-cost of phosphate production. We also propose that the O(2)-deficit for the slow-component is more likely to reflect shifting Delta.VO(2SS) rather than a single one with a single tau.

  6. Isometric strength training lowers the O2 cost of cycling during moderate-intensity exercise.

    PubMed

    Zoladz, Jerzy A; Szkutnik, Zbigniew; Majerczak, Joanna; Grandys, Marcin; Duda, Krzysztof; Grassi, Bruno

    2012-12-01

    The effect of maximal voluntary isometric strength training of knee extensor muscles on pulmonary V'O(2) on-kinetics, the O(2) cost of cycling and peak oxygen uptake (V'O(2peak)) in humans was studied. Seven healthy males (mean ± SD, age 22.3 ± 2.0 years, body weight 75.0 ± 9.2 kg, V'O(2peak) 49.5 ± 3.8 ml kg(-1) min(-1)) performed maximal isometric strength training lasting 7 weeks (4 sessions per week). Force during maximal voluntary contraction (MVC) increased by 15 % (P < 0.001) after 1 week of training, and by 19 % (P < 0.001) after 7 weeks of training. This increase in MVC was accompanied by no significant changes in the time constant of the V'O(2) on-kinetics during 6 min of moderate and heavy cycling intensities. Strength training resulted in a significant decrease (by ~7 %; P < 0.02) in the amplitude of the fundamental component of the V'O(2) on-kinetics, and therefore in a lower O(2) cost of cycling during moderate cycling intensity. The amplitude of the slow component of V'O(2) on-kinetics during heavy cycling intensity did not change with training. Training had no effect on the V'O(2peak), whereas the maximal power output reached at V'O(2peak) was slightly but significantly increased (P < 0.05). Isometric strength training rapidly (i.e., after 1 week) decreases the O(2) cost of cycling during moderate-intensity exercise, whereas it does not affect the amplitude of the slow component of the V'O(2) on-kinetics during heavy-intensity exercise. Isometric strength training can have beneficial effects on performance during endurance events.

  7. The oxygen uptake slow component at submaximal intensities in breaststroke swimming

    PubMed Central

    Oliveira, Diogo R.; Gonçalves, Lio F.; Reis, António M.; Fernandes, Ricardo J.; Garrido, Nuno D.

    2016-01-01

    Abstract The present work proposed to study the oxygen uptake slow component (VO2 SC) of breaststroke swimmers at four different intensities of submaximal exercise, via mathematical modeling of a multi-exponential function. The slow component (SC) was also assessed with two different fixed interval methods and the three methods were compared. Twelve male swimmers performed a test comprising four submaximal 300 m bouts at different intensities where all expired gases were collected breath by breath. Multi-exponential modeling showed values above 450 ml·min−1 of the SC in the two last bouts of exercise (those with intensities above the lactate threshold). A significant effect of the method that was used to calculate the VO2 SC was revealed. Higher mean values were observed when using mathematical modeling compared with the fixed interval 3rd min method (F=7.111; p=0.012; η2=0.587); furthermore, differences were detected among the two fixed interval methods. No significant relationship was found between the SC determined by any method and the blood lactate measured at each of the four exercise intensities. In addition, no significant association between the SC and peak oxygen uptake was found. It was concluded that in trained breaststroke swimmers, the presence of the VO2 SC may be observed at intensities above that corresponding to the 3.5 mM-1 threshold. Moreover, mathematical modeling of the oxygen uptake on-kinetics tended to show a higher slow component as compared to fixed interval methods. PMID:28149379

  8. Relationship between oxygen uptake slow component and surface EMG during heavy exercise in humans: influence of pedal rate.

    PubMed

    Vercruyssen, Fabrice; Missenard, Olivier; Brisswalter, Jeanick

    2009-08-01

    The aim of this study was to test the hypothesis that extreme pedal rates contributed to the slow component of oxygen uptake (VO(2) SC) in association with changes in surface electromyographic (sEMG) during heavy-cycle exercise. Eight male trained cyclists performed two square-wave transitions at 50 and 110 rpm at a work rate that would elicit a VO(2) corresponding to 50% of the difference between peak VO(2) and the ventilatory threshold. Pulmonary gas exchange was measured breath-by-breath and sEMG was obtained from the vastus lateralis and medialis muscles. Integrated EMG flow (QiEMG) and mean power frequency (MPF) were computed. The relative amplitude of the VO(2) SC was significantly higher during the 110-rpm bout (556+/-186 ml min(-1), P<0.05) with compared to the 50-rpm bout (372+/-227 ml min(-1)). QiEMG values increased throughout exercise only during the 110-rpm bout and were associated with the greater amplitude of the VO(2) SC observed for this condition (P<0.05). MPF values remained relatively constant whatever the cycle bout. These findings indicated a VO(2) SC at the two pedal rates but the association with sEMG responses was observed only at high pedal rate. Possible changes in motor units recruitment pattern, muscle energy turnover and muscle temperature have been suggested to explain the different VO(2) SC to heavy pedal rate bouts.

  9. Time limit and VO2 slow component at intensities corresponding to VO2max in swimmers.

    PubMed

    Fernandes, R J; Cardoso, C S; Soares, S M; Ascensão, A; Colaço, P J; Vilas-Boas, J P

    2003-11-01

    The purpose of this study was to measure, in swimming pool conditions and with high level swimmers, the time to exhaustion at the minimum velocity that elicits maximal oxygen consumption (TLim at vVO(2)max), and the corresponding VO(2) slow component (O(2)SC). The vVO(2)max was determined through an intermittent incremental test (n = 15). Forty-eight hours later, TLim was assessed using an all-out swim at vVO(2)max until exhaustion. VO(2) was measured through direct oximetry and the swimming velocity was controlled using a visual light-pacer. Blood lactate concentrations and heart rate values were also measured. Mean VO(2)max for the incremental test was 5.09 +/- 0.53 l/min and the corresponding vVO(2)max was 1.46 +/- 0.06 m/s. Mean TLim value was 260.20 +/- 60.73 s and it was inversely correlated with the velocity of anaerobic threshold (r = -0.54, p < 0.05). This fact, associated with the inverse relationship between TLim and vVO(2)max (r = -0.47, but only for p < 0.10), suggested that swimmers' lower level aerobic metabolic rate might be associated with a larger capacity to sustain that exercise intensity. O(2)SC reached 274.11 +/- 152.83 l/min and was correlated with TLim (r = 0.54), increased ventilation in TLim test (r = 0.52) and energy cost of the respiratory muscles (r = 0.51), for p < 0.05. These data suggest that O(2)SC was also observed in the swimming pool, in high level swimmers performing at vVO(2)max, and that higher TLim seems to correspond to higher expected O(2)SC amplitude. These findings seem to bring new data with application in middle distance swimming.

  10. VO2 Kinetics and Metabolic Contributions Whilst Swimming at 95, 100, and 105% of the Velocity at VO2 max

    PubMed Central

    Sousa, Ana C.; Vilas-Boas, João P.; Fernandes, Ricardo J.

    2014-01-01

    A bioenergetical analysis of swimming at intensities near competitive distances is inexistent. It was aimed to compare the transient VO2 kinetics responses and metabolic contributions whilst swimming at different velocities around VO2max⁡. 12 trained male swimmers performed (i) an incremental protocol to determine the velocity at VO2max⁡ (vVO2max⁡) and (ii) three square wave exercises from rest to 95, 100, and 105% of vVO2max⁡. VO2 was directly measured using a telemetric portable gas analyser and its kinetics analysed through a double-exponential model. Metabolic contributions were assessed through the sum of three energy components. No differences were observed in the fast component response (τ 1—15, 18, and 16 s, A 1—36, 34, and 37 mL · kg−1 · min⁡−1, and Gain—32, 29, and 30 mL · min⁡−1 at 95, 100, and 105% of the vVO2max⁡, resp.) but A2 was higher in 95 and 100% compared to 105% intensity (480.76 ± 247.01, 452.18 ± 217.04, and 147.04 ± 60.40 mL · min⁡−1, resp.). The aerobic energy contribution increased with the time sustained (83 ± 5, 74 ± 6, and 59 ± 7% for 95, 100, and 105%, resp.). The adjustment of the cardiovascular and/or pulmonary systems that determine O2 delivery and diffusion to the exercising muscles did not change with changing intensity, with the exception of VO2 slow component kinetics metabolic profiles. PMID:25045690

  11. O2 uptake kinetics during exercise at peak O2 uptake.

    PubMed

    Scheuermann, Barry W; Barstow, Thomas J

    2003-11-01

    Compared with moderate- and heavy-intensity exercise, the adjustment of O2 uptake (VO2) to exercise intensities that elicit peak VO2 has received relatively little attention. This study examined the VO2 response of 21 young, healthy subjects (25 +/- 6 yr; mean +/- SD) during cycle ergometer exercise to step transitions in work rate (WR) corresponding to 90, 100, and 110% of the peak WR achieved during a preliminary ramp protocol (15-30 W/min). Gas exchange was measured breath by breath and interpolated to 1-s values. VO2 kinetics were determined by use of a two- or three-component exponential model to isolate the time constant (tau2) as representative of VO2 kinetics and the amplitude (Amp) of the primary fast component independent of the appearance of any VO2 slow component. No difference in VO2 kinetics was observed between WRs (tau90 = 24.7 +/- 9.0; tau100 = 22.8 +/- 6.7; tau110 = 21.5 +/- 9.2 s, where subscripts denote percent of peak WR; P > 0.05); nor in a subgroup of eight subjects was tau2 different from the value for moderate-intensity ( 0.05). As expected, the Amp increased with increasing WRs (Amp90 = 2,089 +/- 548; Amp100 = 2,165 +/- 517; Amp110 = 2,225 +/- 559 ml/min; Amp90 vs. Amp110, P < 0.05). However, the gain (G) of the VO2 response (deltaVO2/deltaWR) decreased with increasing WRs (G90 = 8.5 +/- 0.6; G100 = 7.9 +/- 0.6; G110 = 7.3 +/- 0.6 ml.min-1.W-1; P < 0.05). The Amp of the primary component approximated 85, 88, and 89% of peak Vo2 during 90, 100, and 110% WR transitions, respectively. The results of the present study demonstrate that, compared with moderate- and heavy-intensity exercise, the gain of the Vo2 response (as deltaVO2/DeltaWR) is reduced for exercise transitions in the severe-intensity domain, but the approach to this gain is well described by a common time constant that is invariant across work intensities. The lower deltaVO2/deltaWR may be due to an insufficient adjustment of the cardiovascular and/or pulmonary systems that determine O2 delivery to the exercising muscles or due to recruitment of motor units with lower oxidative capacity, after the onset of exercise in the severe-intensity domain.

  12. Effects of training status and exercise intensity on phase II VO2 kinetics.

    PubMed

    Koppo, Katrien; Bouckaert, Jacques; Jones, Andrew M

    2004-02-01

    To test the hypotheses that: 1) the time constant for the fast component of .VO2 kinetics (tau1) at exercise onset would be faster in trained than in untrained subjects for both moderate and heavy exercise, and that 2) tau1 would become progressively slower in untrained subjects at higher power outputs but be invariant in trained subjects. Eight untrained subjects (.VO2peak: 42.9 +/- 5.1 mL.kg-1.min-1) and seven trained cyclists (.VO2peak: 66.6 +/- 2.5 mL.kg-1.min-1) completed square-wave transitions to power outputs requiring 60% and 80% of gas exchange threshold (GET), and 50% of the difference between GET and .VO2 peak (50%Delta) from a baseline of "unloaded" cycling. .VO2 was measured breath-by-breath and individual responses were modeled using nonlinear regression techniques. A repeated measures ANOVA revealed that the tau1 was significantly smaller (i.e., the kinetics were faster) in the trained compared with the untrained subjects and that tau1 became significantly greater (i.e., the kinetics were slowed) at higher power outputs both in the untrained (60%GET: 17.8 +/- 3.8 s, 80%GET: 21.5 +/- 6.6 s, and 50%Delta: 23.5 +/- 2.8 s) and the trained (60%GET: 8.9 +/- 1.3 s, 80%GET: 11.7 +/- 2.5 s, and 50%Delta: 15.2 +/- 2.0 s) subjects (P < 0.05). Phase II .VO2 kinetics became progressively slower at higher power outputs in both trained and untrained subjects. That a greater tau1 was evident at a higher power output within the moderate exercise intensity domain (

  13. [Cardiopulmonary dynamics during a maximal exertion test in Mexican endurance athletes].

    PubMed

    Padilla, J; Martínez, E; Olvera, G; Ojeda Cruz, P; Caudillo Pérez, D

    2000-01-01

    To search for cardiopulmonary (CP) kinetic and dynamic differences between Mexican resistance athletes (RES = 10) and non athletes (NON = 19). From the expired volume (Ve), measured by an open circuit spirometry, we calculated both VO2 and VCO2 during stress test while the volunteer pedalled seated on an electronic cycloergometer that started at 50 W.2 min-1 followed by increments of 25 W.2 min-1 each, until VO2máx was reached. The exercise transient time course (min) response (VO2, VCO2, Ve and heart rate, HR; and also O2 pulse, PulO2) was transformed to seconds and modelled by computer using linear regression technique by the interactive minimum squares method, and the mean response time (MRT) was used as an overall kinetic CP parameter. The transient MRTs for VO2, VCO2 and Ve were slow in RES compared to NON. While the transient CP dynamics in NON lasted MRT_VO2 < (MRT_PulO2, MRT_FC) < MRT_VCO2 < MRT_Ve; the RES: both MRT_PulO2 and MRT_HR shifted to the right ((MRT_VO2, MRT_VCO2) < (MRT_PulO2, MRT_FC) < MRT_Ve). The relationships between the best sport profit mean velocity and both the MRT_VO2, MRT_VCO2 and MRT_PulO2 (GEK = gas exchange kinetics) showed fast_RES and slow_GEK, and slow_RES and fast_GEK. The transient CP kinetics was slow in RES compared NON. It is possible to distinguish cardiopulmonary kinetic differences among resistance athletes holding different sport profiles.

  14. Time to Exhaustion at the VO2max Velocity in Swimming: A Review

    PubMed Central

    Fernandes, Ricardo J.; Vilas-Boas, J. Paulo

    2012-01-01

    The aim of this study was to present a review on the time to exhaustion at the minimum swimming velocity corresponding to maximal oxygen consumption (TLim-vVO2max). This parameter is critical both for the aerobic power and the lactate tolerance bioenergetical training intensity zones, being fundamental to characterize it, and to point out its main determinants. The few number of studies conducted in this topic observed that swimmers were able to maintain an exercise intensity corresponding to maximal aerobic power during 215 to 260 s (elite swimmers), 230 to 260 s (high level swimmers) and 310 to 325 s (low level swimmers), and no differences between genders were reported. TLim-vVO2max main bioenergetic and functional determinants were swimming economy and VO2 slow component (direct relationship), and vVO2max, velocity at anaerobic threshold and blood lactate production (inverse relationship); when more homogeneous groups of swimmers were analysed, the inverse correlation value between TLim-vVO2max and vVO2max was not so evident. In general, TLim-vVO2max was not related to VO2max. TLim-vVO2max seems also to be influenced by stroking parameters, with a direct relationship to stroke length and stroke index, and an inverse correlation with stroke rate. Assessing TLim-vVO2max, together with the anaerobic threshold and the biomechanical general parameters, will allow a larger spectrum of testing protocols application, helping to build more objective and efficient training programs. PMID:23486651

  15. Effect of a prior intermittent run at vVO2max on oxygen kinetics during an all-out severe run in humans.

    PubMed

    Billat, V L; Bocquet, V; Slawinski, J; Laffite, L; Demarle, A; Chassaing, P; Koralsztein, J P

    2000-09-01

    The purpose of this study was to examine the influence of prior intermittent running at VO2max on oxygen kinetics during a continuous severe intensity run and the time spent at VO2max. Eight long-distance runners performed three maximal tests on a synthetic track (400 m) whilst breathing through the COSMED K4 portable telemetric metabolic analyser: i) an incremental test which determined velocity at the lactate threshold (vLT), VO2max and velocity associated with VO2max (vVO2max), ii) a continuous severe intensity run at vLT+50% (vdelta50) of the difference between vLT and vVO2max (91.3+/-1.6% VO2max)preceded by a light continuous 20 minute run at 50% of vVO2max (light warm-up), iii) the same continuous severe intensity run at vdelta50 with a prior interval training exercise (hard warm-up) of repeated hard running bouts performed at 100% of vVO2max and light running at 50% of vVO2max (of 30 seconds each) performed until exhaustion (on average 19+/-5 min with 19+/-5 interval repetitions). This hard warm-up speeded the VO2 kinetics: the time constant was reduced by 45% (28+/-7 sec vs 51+/-37 sec) and the slow component of VO2 (deltaVO2 6-3 min) was deleted (-143+/-271 ml x min(-1) vs 291+/-153 ml x min(-1)). In conclusion, despite a significantly lower total run time at vdelta50 (6 min 19+/-0) min 17 vs 8 min 20+/-1 min 45, p=0.02) after the intermittent warm-up at VO2max, the time spent specifically at VO2max in the severe continuous run at vdelta50 was not significantly different.

  16. Pulmonary and leg VO2 during submaximal exercise: implications for muscular efficiency

    NASA Technical Reports Server (NTRS)

    Poole, D. C.; Gaesser, G. A.; Hogan, M. C.; Knight, D. R.; Wagner, P. D.

    1992-01-01

    Insights into muscle energetics during exercise (e.g., muscular efficiency) are often inferred from measurements of pulmonary gas exchange. This procedure presupposes that changes of pulmonary O2 (VO2) associated with increases of external work reflect accurately the increased muscle VO2. The present investigation addressed this issue directly by making simultaneous determinations of pulmonary and leg VO2 over a range of work rates calculated to elicit 20-90% of maximum VO2 on the basis of prior incremental (25 or 30 W/min) cycle ergometry. VO2 for both legs was calculated as the product of twice one-leg blood flow (constant-infusion thermodilution) and arteriovenous O2 content difference across the leg. Measurements were made 3-5 min after each work rate imposition to avoid incorporation of the VO2 slow component above the lactate threshold. For all 17 subjects, the slope of pulmonary VO2 (9.9 +/- 0.2 ml O2.W-1.min-1) was not different (P greater than 0.05) from that for leg VO2 (9.2 +/- 0.6 ml O2.W-1.min-1). Estimation of "delta" efficiency (i.e., delta work accomplished divided by delta energy expended, calculated from slope of VO2 vs. work rate and a caloric equivalent for O2 of 4.985 cal/ml) using pulmonary VO2 measurements (29.1 +/- 0.6%) was likewise not significantly different (P greater than 0.05) from that made using leg VO2 measurements (33.7 +/- 2.4%). These data suggest that the net VO2 cost of metabolic "support" processes outside the exercising legs changes little over a relatively broad range of exercise intensities. Thus, under the conditions of this investigation, changes of VO2 measured from expired gas reflected closely those occurring within the exercising legs.

  17. The influence of exercise duration at VO2 max on the off-transient pulmonary oxygen uptake phase during high intensity running activity.

    PubMed

    Billat, V L; Hamard, L; Koralsztein, J P

    2002-12-01

    The purpose of this study was to examine the influence of time run at maximal oxygen uptake (VO2 max) on the off-transient pulmonary oxygen uptake phase after supra-lactate threshold runs. We hypothesised: 1) that among the velocities eliciting VO2 max there is a velocity threshold from which there is a slow component in the VO2-off transient, and 2) that at this velocity the longer the duration of this time at VO2 max (associated with an accumulated oxygen kinetics since VO2 can not overlap VO2 max), the longer is the off-transient phase of oxygen uptake kinetics. Nine long-distance runners performed five maximal tests on a synthetic track (400 m) while breathing through the COSMED K4b2 portable, telemetric metabolic analyser: i) an incremental test which determined VO2 max, the minimal velocity associated with VO2 max (vVO2 max) and the velocity at the lactate threshold (vLT), ii) and in a random order, four supra-lactate threshold runs performed until exhaustion at vLT + 25, 50, 75 and 100% of the difference between vLT and vVO2 max (vdelta25, vdelta50, vdelta75, vdelta100). At vdelta25, vdelta50 (= 91.0 +/- 0.9% vVO2 max) and vdelta75, an asymmetry was found between the VO2 on (double exponential) and off-transient (mono exponential) phases. Only at vdelta75 there was at positive relationship between the time run at VO2 max (%tlimtot) and the VO2 recovery time constant (Z = 1.8, P = 0.05). In conclusion, this study showed that among the velocities eliciting VO2 max, vdelta75 is the velocity at which the longer the duration of the time at VO2 max, the longer is the off-transient phase of oxygen uptake kinetics. It may be possible that at vdelta50 there is not an accumulated oxygen deficit during the plateau of VO2 at VO2 max and that the duration of the time at VO2 max during the exhaustive runs at vdelta100, could be too short to induce an accumulating oxygen deficit affecting the oxygen recovery.

  18. Walking energetics, fatigability, and fatigue in older adults: the study of energy and aging pilot.

    PubMed

    Richardson, Catherine A; Glynn, Nancy W; Ferrucci, Luigi G; Mackey, Dawn C

    2015-04-01

    Slow gait speed increases morbidity and mortality in older adults. We examined how preferred gait speed is associated with energetic requirements of walking, fatigability, and fatigue. Older adults (n = 36, 70-89 years) were categorized as slow or fast walkers based on median 400-m gait speed. We measured VO2peak by graded treadmill exercise test and VO2 during 5-minute treadmill walking tests at standard (0.72 m/s) and preferred gait speeds. Fatigability was assessed with the Situational Fatigue Scale and the Borg rating of perceived exertion at the end of walking tests. Fatigue was assessed by questionnaire. Preferred gait speed over 400 m (range: 0.75-1.58 m/s) averaged 1.34 m/s for fast walkers versus 1.05 m/s for slow walkers (p < .001). VO2peak was 26% lower (18.5 vs 25.1ml/kg/min, p = .001) in slow walkers than fast walkers. To walk at 0.72 m/s, slow walkers used a larger percentage of VO2peak (59% vs 42%, p < .001). To walk at preferred gait speed, slow walkers used more energy per unit distance (0.211 vs 0.186ml/kg/m, p = .047). Slow walkers reported higher rating of perceived exertion during walking and greater overall fatigability on the Situational Fatigue Scale, but no differences in fatigue. Slow walking was associated with reduced aerobic capacity, greater energetic cost of walking, and greater fatigability. Interventions to improve aerobic capacity or decrease energetic cost of walking may prevent slowing of gait speed and promote mobility in older adults. © The Author 2014. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Walking Energetics, Fatigability, and Fatigue in Older Adults: The Study of Energy and Aging Pilot

    PubMed Central

    Richardson, Catherine A.; Glynn, Nancy W.; Ferrucci, Luigi G.

    2015-01-01

    Background. Slow gait speed increases morbidity and mortality in older adults. We examined how preferred gait speed is associated with energetic requirements of walking, fatigability, and fatigue. Methods. Older adults (n = 36, 70–89 years) were categorized as slow or fast walkers based on median 400-m gait speed. We measured VO2peak by graded treadmill exercise test and VO2 during 5-minute treadmill walking tests at standard (0.72 m/s) and preferred gait speeds. Fatigability was assessed with the Situational Fatigue Scale and the Borg rating of perceived exertion at the end of walking tests. Fatigue was assessed by questionnaire. Results. Preferred gait speed over 400 m (range: 0.75–1.58 m/s) averaged 1.34 m/s for fast walkers versus 1.05 m/s for slow walkers (p < .001). VO2peak was 26% lower (18.5 vs 25.1ml/kg/min, p = .001) in slow walkers than fast walkers. To walk at 0.72 m/s, slow walkers used a larger percentage of VO2peak (59% vs 42%, p < .001). To walk at preferred gait speed, slow walkers used more energy per unit distance (0.211 vs 0.186ml/kg/m, p = .047). Slow walkers reported higher rating of perceived exertion during walking and greater overall fatigability on the Situational Fatigue Scale, but no differences in fatigue. Conclusions. Slow walking was associated with reduced aerobic capacity, greater energetic cost of walking, and greater fatigability. Interventions to improve aerobic capacity or decrease energetic cost of walking may prevent slowing of gait speed and promote mobility in older adults. PMID:25190069

  20. VO2 Off Transient Kinetics in Extreme Intensity Swimming.

    PubMed

    Sousa, Ana; Figueiredo, Pedro; Keskinen, Kari L; Rodríguez, Ferran A; Machado, Leandro; Vilas-Boas, João P; Fernandes, Ricardo J

    2011-01-01

    Inconsistencies about dynamic asymmetry between the on- and off- transient responses in oxygen uptake are found in the literature. Therefore, the purpose of this study was to characterize the oxygen uptake off-transient kinetics during a maximal 200-m front crawl effort, as examining the degree to which the on/off regularity of the oxygen uptake kinetics response was preserved. Eight high level male swimmers performed a 200-m front crawl at maximal speed during which oxygen uptake was directly measured through breath-by-breath oxymetry (averaged every 5 s). This apparatus was connected to the swimmer by a low hydrodynamic resistance respiratory snorkel and valve system. The on- and off-transient phases were symmetrical in shape (mirror image) once they were adequately fitted by a single-exponential regression models, and no slow component for the oxygen uptake response was developed. Mean (± SD) peak oxygen uptake was 69.0 (± 6.3) mL·kg(-1)·min(-1), significantly correlated with time constant of the off- transient period (r = 0.76, p < 0.05) but not with any of the other oxygen off-transient kinetic parameters studied. A direct relationship between time constant of the off-transient period and mean swimming speed of the 200-m (r = 0.77, p < 0.05), and with the amplitude of the fast component of the effort period (r = 0.72, p < 0.05) were observed. The mean amplitude and time constant of the off-transient period values were significantly greater than the respective on- transient. In conclusion, although an asymmetry between the on- and off kinetic parameters was verified, both the 200-m effort and the respectively recovery period were better characterized by a single exponential regression model. Key pointsThe VO2 slow component was not observed in the recovery period of swimming extreme efforts;The on and off transient periods were better fitted by a single exponential function, and so, these effort and recovery periods of swimming extreme efforts are symmetrical;The rate of VO2 decline during the recovery period may be due to not only the magnitude of oxygen debt but also the VO2peak obtained during the effort period.

  1. Effects of prior heavy exercise on VO(2) kinetics during heavy exercise are related to changes in muscle activity.

    PubMed

    Burnley, Mark; Doust, Jonathan H; Ball, Derek; Jones, Andrew M

    2002-07-01

    We hypothesized that the elevated primary O(2) uptake (VO(2)) amplitude during the second of two bouts of heavy cycle exercise would be accompanied by an increase in the integrated electromyogram (iEMG) measured from three leg muscles (gluteus maximus, vastus lateralis, and vastus medialis). Eight healthy men performed two 6-min bouts of heavy leg cycling (at 70% of the difference between the lactate threshold and peak VO(2)) separated by 12 min of recovery. The iEMG was measured throughout each exercise bout. The amplitude of the primary VO(2) response was increased after prior heavy leg exercise (from mean +/- SE 2.11 +/- 0.12 to 2.44 +/- 0.10 l/min, P < 0.05) with no change in the time constant of the primary response (from 21.7 +/- 2.3 to 25.2 +/- 3.3 s), and the amplitude of the VO(2) slow component was reduced (from 0.79 +/- 0.08 to 0.40 +/- 0.08 l/min, P < 0.05). The elevated primary VO(2) amplitude after leg cycling was accompanied by a 19% increase in the averaged iEMG of the three muscles in the first 2 min of exercise (491 +/- 108 vs. 604 +/- 151% increase above baseline values, P < 0.05), whereas mean power frequency was unchanged (80.1 +/- 0.9 vs. 80.6 +/- 1.0 Hz). The results of the present study indicate that the increased primary VO(2) amplitude observed during the second of two bouts of heavy exercise is related to a greater recruitment of motor units at the onset of exercise.

  2. Removing the thermal component from heart rate provides an accurate VO2 estimation in forest work.

    PubMed

    Dubé, Philippe-Antoine; Imbeau, Daniel; Dubeau, Denise; Lebel, Luc; Kolus, Ahmet

    2016-05-01

    Heart rate (HR) was monitored continuously in 41 forest workers performing brushcutting or tree planting work. 10-min seated rest periods were imposed during the workday to estimate the HR thermal component (ΔHRT) per Vogt et al. (1970, 1973). VO2 was measured using a portable gas analyzer during a morning submaximal step-test conducted at the work site, during a work bout over the course of the day (range: 9-74 min), and during an ensuing 10-min rest pause taken at the worksite. The VO2 estimated, from measured HR and from corrected HR (thermal component removed), were compared to VO2 measured during work and rest. Varied levels of HR thermal component (ΔHRTavg range: 0-38 bpm) originating from a wide range of ambient thermal conditions, thermal clothing insulation worn, and physical load exerted during work were observed. Using raw HR significantly overestimated measured work VO2 by 30% on average (range: 1%-64%). 74% of VO2 prediction error variance was explained by the HR thermal component. VO2 estimated from corrected HR, was not statistically different from measured VO2. Work VO2 can be estimated accurately in the presence of thermal stress using Vogt et al.'s method, which can be implemented easily by the practitioner with inexpensive instruments. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  3. Very short (15s-15s) interval-training around the critical velocity allows middle-aged runners to maintain VO2 max for 14 minutes.

    PubMed

    Billat, V L; Slawinksi, J; Bocquet, V; Chassaing, P; Demarle, A; Koralsztein, J P

    2001-04-01

    The purpose of this study was to compare the effectiveness of three very short interval training sessions (15-15 s of hard and easier runs) run at an average velocity equal to the critical velocity to elicit VO2 max for more than 10 minutes. We hypothesized that the interval with the smallest amplitude (defined as the ratio between the difference in velocity between the hard and the easy run divided by the average velocity and multiplied by 100) would be the most efficient to elicit VO2 max for the longer time. The subjects were middle-aged runners (52 +/- 5 yr, VO2 max of 52.1 +/- 6 mL x min(-1) x kg(-1), vVO2 max of 15.9 +/- 1.8 km x h(-1), critical velocity of 85.6 +/- 1.2% vVO2 max) who were used to long slow distance-training rather than interval training. They performed three interval-training (IT) sessions on a synthetic track (400 m) whilst breathing through the COSMED K4b2 portable metabolic analyser. These three IT sessions were: A) 90-80% vVO2 max (for hard bouts and active recovery periods, respectively), the amplitude= (90-80/85) 100=11%, B) 100-70% vVO2 max amplitude=35%, and C) 60 x 110% vVO2 max amplitude = 59%. Interval training A and B allowed the athlete to spend twice the time at VO2 max (14 min vs. 7 min) compared to interval training C. Moreover, at the end of interval training A and B the runners had a lower blood lactate than after the procedure C (9 vs. 11 mmol x l(-1)). In conclusion, short interval-training of 15s-15s at 90-80 and 100-70% of vVO2 max proved to be the most efficient in stimulating the oxygen consumption to its highest level in healthy middle-aged long-distance runners used to doing only long slow distance-training.

  4. Endurance Performance during Severe-Intensity Intermittent Cycling: Effect of Exercise Duration and Recovery Type.

    PubMed

    Barbosa, Luis F; Denadai, Benedito S; Greco, Camila C

    2016-01-01

    Slow component of oxygen uptake (VO 2 SC) kinetics and maximal oxygen uptake (VO 2 max) attainment seem to influence endurance performance during constant-work rate exercise (CWR) performed within the severe intensity domain. In this study, it was hypothesized that delaying the attainment of VO 2 max by reducing the rates at which VO 2 increases with time (VO 2 SC kinetics) would improve the endurance performance during severe-intensity intermittent exercise performed with different work:recovery duration and recovery type in active individuals. After the estimation of the parameters of the VO 2 SC kinetics during CWR exercise, 18 males were divided into two groups (Passive and Active recovery) and performed at different days, two intermittent exercises to exhaustion (at 95% IVO 2 max, with work: recovery ratio of 2:1) with the duration of the repetitions calculated from the onset of the exercise to the beginning of the VO 2 SC (Short) or to the half duration of the VO 2 SC (Long). The active recovery was performed at 50% IVO 2 max. The endurance performance during intermittent exercises for the Passive (Short = 1523 ± 411; Long = 984 ± 260 s) and Active (Short = 902 ± 239; Long = 886 ± 254 s) groups was improved compared with CWR condition (Passive = 540 ± 116; Active = 489 ± 84 s). For Passive group, the endurance performance was significantly higher for Short than Long condition. However, no significant difference between Short and Long conditions was found for Active group. Additionally, the endurance performance during Short condition was higher for Passive than Active group. The VO 2 SC kinetics was significantly increased for CWR (Passive = 0.16 ± 0.04; Active = 0.16 ± 0.04 L.min -2 ) compared with Short (Passive = 0.01 ± 0.01; Active = 0.03 ± 0.04 L.min -2 ) and Long (Passive = 0.02 ± 0.01; Active = 0.01 ± 0.01 L.min -2 ) intermittent exercise conditions. No significant difference was found among the intermittent exercises. It can be concluded that the endurance performance is negatively influenced by active recovery only during shorter high-intensity intermittent exercise. Moreover, the improvement in endurance performance seems not be explained by differences in the VO 2 SC kinetics, since its values were similar among all intermittent exercise conditions.

  5. Ab Initio Metadynamics Study of the VO2+/VO2+ Redox Reaction Mechanism at the Graphite Edge/Water Interface.

    PubMed

    Jiang, Zhen; Klyukin, Konstantin; Alexandrov, Vitaly

    2018-06-20

    Redox flow batteries (RFBs) are promising electrochemical energy storage systems, for which development is impeded by a poor understanding of redox reactions occurring at electrode/electrolyte interfaces. Even for the conventional all-vanadium RFB chemistry employing V 2+ /V 3+ and VO 2 + /VO 2+ couples, there is still no consensus about the reaction mechanism, electrode active sites, and rate-determining step. Herein, we perform Car-Parrinello molecular dynamics-based metadynamics simulations to unravel the mechanism of the VO 2 + /VO 2+ redox reaction in water at the oxygen-functionalized graphite (112̅0) edge surface serving as a representative carbon-based electrode. Our results suggest that during the battery discharge aqueous VO 2 + /VO 2+ species adsorb at the surface C-O groups as inner-sphere complexes, exhibiting faster adsorption/desorption kinetics than V 2+ /V 3+ , at least at low vanadium concentrations considered in our study. We find that this is because (i) VO 2 + /VO 2+ conversion does not involve the slow transfer of an oxygen atom, (ii) protonation of VO 2 + is spontaneous and coupled to interfacial electron transfer in acidic conditions to enable VO 2+ formation, and (iii) V 3+ found to be strongly bound to oxygen groups of the graphite surface features unfavorable desorption kinetics. In contrast, the reverse process taking place upon charging is expected to be more sluggish for the VO 2 + /VO 2+ redox couple because of both unfavorable deprotonation of the VO 2+ water ligands and adsorption/desorption kinetics.

  6. Pulmonary O2 uptake and leg blood flow kinetics during moderate exercise are slowed by hyperventilation-induced hypocapnic alkalosis.

    PubMed

    Chin, Lisa M K; Heigenhauser, George J F; Paterson, Donald H; Kowalchuk, John M

    2010-06-01

    The effect of hyperventilation-induced hypocapnic alkalosis (Hypo) on the adjustment of pulmonary O2 uptake (VO2p) and leg femoral conduit artery ("bulk") blood flow (LBF) during moderate-intensity exercise (Mod) was examined in eight young male adults. Subjects completed four to six repetitions of alternate-leg knee-extension exercise during normal breathing [Con; end-tidal partial pressure of CO2 (PetCO2) approximately 40 mmHg] and sustained hyperventilation (Hypo; PetCO2 approximately 20 mmHg). Increases in work rate were made instantaneously from baseline (3 W) to Mod (80% estimated lactate threshold). VO2p was measured breath by breath by mass spectrometry and volume turbine, and LBF (calculated from mean femoral artery blood velocity and femoral artery diameter) was measured simultaneously by Doppler ultrasound. Concentration changes of deoxy (Delta[HHb])-, oxy (Delta[O2Hb])-, and total hemoglobin-myoglobin (Delta[HbTot]) of the vastus lateralis muscle were measured continuously by near-infrared spectroscopy (NIRS). The kinetics of VO2p, LBF, and Delta[HHb] were modeled using a monoexponential equation by nonlinear regression. The time constants for the phase 2 VO2p (Hypo, 49+/-26 s; Con, 28+/-8 s) and LBF (Hypo, 46+/-16 s; Con, 23+/-6 s) were greater (P<0.05) in Hypo compared with Con. However, the mean response time for the overall Delta[HHb] response was not different between conditions (Hypo, 23+/-5 s; Con, 24+/-3 s), whereas the Delta[HHb] amplitude was greater (P<0.05) in Hypo (8.05+/-7.47 a.u.) compared with Con (6.69+/-6.31 a.u.). Combined, these results suggest that hyperventilation-induced hypocapnic alkalosis is associated with slower convective (i.e., slowed femoral artery and microvascular blood flow) and diffusive (i.e., greater fractional O2 extraction for a given DeltaVO2p) O2 delivery, which may contribute to the hyperventilation-induced slowing of VO2p (and muscle O2 utilization) kinetics.

  7. Effects of circuit low-intensity resistance exercise with slow movement on oxygen consumption during and after exercise.

    PubMed

    Mukaimoto, Takahiro; Ohno, Makoto

    2012-01-01

    The purpose of this study was to examine oxygen consumption (VO(2)) during and after a single bout of low-intensity resistance exercise with slow movement. Eleven healthy men performed the following three types of circuit resistance exercise on separate days: (1) low-intensity resistance exercise with slow movement: 50% of one-repetition maximum (1-RM) and 4 s each of lifting and lowering phases; (2) high-intensity resistance exercise with normal movement: 80% of 1-RM and 1 s each of lifting and lowering phases; and (3) low-intensity resistance exercise with normal movement: 50% of 1-RM and 1 s each of lifting and lowering phases. These three resistance exercise trials were performed for three sets in a circuit pattern with four exercises, and the participants performed each set until exhaustion. Oxygen consumption was monitored continuously during exercise and for 180 min after exercise. Average VO(2) throughout the exercise session was significantly higher with high- and low-intensity resistance exercise with normal movement than with low-intensity resistance exercise with slow movement (P < 0.05); however, total VO(2) was significantly greater in low-intensity resistance exercise with slow movement than in the other trials. In contrast, there were no significant differences in the total excess post-exercise oxygen consumption among the three exercise trials. The results of this study suggest that low-intensity resistance exercise with slow movement induces much greater energy expenditure than resistance exercise with normal movement of high or low intensity, and is followed by the same total excess post-exercise oxygen consumption for 180 min after exercise.

  8. Gap-Junctional communication between developing Drosophila muscles is essential for their normal development.

    PubMed

    Todman, M G; Baines, R A; Stebbings, L A; Davies, J A; Bacon, J P

    1999-01-01

    Recent experiments have demonstrated that a family of proteins, known as the innexins, are structural components of invertebrate gap junctions. The shaking-B (shak-B) locus of Drosophila encodes two members of this emerging family, Shak-B(lethal) and Shak-B(neural). This study focuses on the role of Shak-B gap junctions in the development of embryonic and larval muscle. During embryogenesis, shak-B transcripts are expressed in a subset of the somatic muscles; expression is strong in ventral oblique muscles (VO4-6) but only weak in ventral longitudinals (VL3 and 4). Carboxyfluorescein injected into VO4 of wild-type early stage 16 embryos spreads, via gap junctions, to label adjacent muscles, including VL3 and 4. In shak-B2 embryos (in which the shak-B(neural) function is disrupted), dye injected into VO4 fails to spread into other muscles. In the first instar larva, when dye coupling between muscles is no longer present, another effect of the shak-B2 mutation is revealed by whole-cell voltage clamp. In a calcium-free saline, only two voltage-activated potassium currents are present in wild-type muscles; a fast IA and a slow IK current. In shak-B2 larvae, these two currents are significantly reduced in magnitude in VO4 and 5, but remain normal in VL3. Expression of shak-B(neural) in a shak-B2 background fully rescues both dye coupling in embryonic muscle and whole-cell currents in first instar VO4 and 5. Our observations show that Shak-B(neural) is one of a set of embryonic gap-junction proteins, and that it is required for the normal temporal development of potassium currents in some larval muscles.

  9. Effect of music-movement synchrony on exercise oxygen consumption.

    PubMed

    Bacon, C J; Myers, T R; Karageorghis, C I

    2012-08-01

    Past research indicates that endurance is improved when exercise movements are synchronised with a musical beat, however it is unclear whether such benefits are associated with reduced metabolic cost. We compared oxygen consumption (.VO2) and related physiological effects of exercise conducted synchronously and asynchronously with music. Three music tracks, each recorded at three different tempi (123, 130, and 137 beats.min-1), accompanied cycle ergometry at 65 pedal revolutions.min-1. Thus three randomly-assigned experimental conditions were administered: slow tempo asynchronous, synchronous, and fast tempo asynchronous. Exercise response of .VO2, HR, and ratings of perceived exertion (RPE), to each condition was monitored in 10 untrained male participants aged 21.7±0.8 years (mean±SD) who cycled for 12 min at 70% maximal heart rate (HR). Mean .VO2 differed among conditions (P=0.008), being lower in the synchronous (1.80±0.22 L.min-1) compared to the slow tempo asynchronous condition (1.94±0.21 L.min-1; P<0.05). There was no difference in HR or RPE among conditions, although HR showed a similar trend to .VO2. The present results indicate that exercise is more efficient when performed synchronously with music than when musical tempo is slightly slower than the rate of cyclical movement.

  10. Muscle mechanics: adaptations with exercise-training.

    PubMed

    Fitts, R H; Widrick, J J

    1996-01-01

    Based on the MHC isoform pattern, adult mammalian limb skeletal muscles contain two and, in some species, three types of fast fibers (Type IIa, IIx, and IIb), and one slow fiber (Type I). Slow muscles, such as the soleus, contain primarily the slow Type I fiber, whereas fast-twitch muscles are composed primarily of a mixture of the fast myosin isozymes. Force generation involves cross-bridge interaction and transition from a weakly bound, low-force state (AM-ADP-P(i)) to the strongly bound, high-force state (AM-ADP). This transition is thought to be rate limiting in terms of dP/dt, and the high-force state is the dominant cross-bridge form during a peak isometric contraction. Intact fast and slow skeletal muscles generate approximately the same amount of peak force (Po) of between 200 and 250 kN.m-2. However, the rate of transition from the low- to high-force state shows Ca2+ sensitivity and is 7-fold higher in fast-twitch, as compared to slow-twitch, skeletal muscle fibers. Fiber Vo or the maximal cross-bridge cycle rate is highly correlated with and thought to be dependent on the specific activity of the myosin or myofibrillar ATPase. The hierarchy for Vo is the Type IIb > IIx > IIa > I. This functional difference for the fast fiber types explains the higher Vo observed in the predominantly Type IIb SVL vs. the mixed fast Type IIa and IIb EDL muscle. A plot of Vo vs. species size demonstrates that an inverse relationship exists between Vo and body mass. From the standpoint of work capacity, the important property is power output. An analysis of individual muscles indicates that peak power is obtained at loads considerably below 50% of Po. Individuals with a high percentage of fast-twitch fibers generate a greater torque and higher power at a given velocity than those with predominantly slow-twitch fibers. In humans, mean peak power occurred in a ratio of 10:5:1 for the Type IIb, IIa, and I fibers. The in vivo measurement of the torque-velocity relationship and Vmax in human muscle is difficult because of limitations inherent in the equipment used and the inability to study the large limb muscles independently. Nevertheless, the in vivo torque-velocity relationships are similar to those measured in vitro in animals. This observation suggests that little central nervous system inhibition exists and that healthy subjects are able to achieve maximal activation of their muscles. Although peak isometric tension is not dependent on fiber type distribution, a positive correlation exists between the percentage of fast fibers and peak torque output at moderate-to-high angular isokinetic velocities. Consequently, peak power output is substantially greater in subjects possessing a predominance of fast fibers. The mechanical properties of slow and fast muscles do adapt to programs of regular exercise. Endurance exercise training has been shown to increase the Vo of the slow soleus by 20%. This increase could have been caused by either a small increase in all, or most, of the fibers, or to a conversion of a few fibers from slow to fast. Recently, the increase was shown to be caused by the former, as the individual slow Type I fibers of the soleus showed a 20% increase in Vo, but there was little or no change in the percentage of fast fibers. The increased Vo was correlated with, and likely caused by, an increased fiber ATPase. We hypothesize that the increased ATPase and cross-bridge cycling speed might be attributable to an increased expression of fast MLCs in the slow Type I fibers (Fig. 14.10). This hypothesis is based on the fact that light chains have been shown to be involved in the power stroke, and removal of light chains depresses force and velocity. Regular endurance exercise training had no effect on fiber size, but with prolonged durations of daily training it depressed Po and peak power. When the training is maintained over prolonged periods, it may even induce atrophy of the slow Type I and fast Type IIa fibers. (ABSTRACT TRUNCATED)

  11. Optimizing the "priming" effect: influence of prior exercise intensity and recovery duration on O2 uptake kinetics and severe-intensity exercise tolerance.

    PubMed

    Bailey, Stephen J; Vanhatalo, Anni; Wilkerson, Daryl P; Dimenna, Fred J; Jones, Andrew M

    2009-12-01

    It has been suggested that a prior bout of high-intensity exercise has the potential to enhance performance during subsequent high-intensity exercise by accelerating the O(2) uptake (Vo(2)) on-response. However, the optimal combination of prior exercise intensity and subsequent recovery duration required to elicit this effect is presently unclear. Eight male participants, aged 18-24 yr, completed step cycle ergometer exercise tests to 80% of the difference between the preestablished gas exchange threshold and maximal Vo(2) (i.e., 80%Delta) after no prior exercise (control) and after six different combinations of prior exercise intensity and recovery duration: 40%Delta with 3 min (40-3-80), 9 min (40-9-80), and 20 min (40-20-80) of recovery and 70%Delta with 3 min (70-3-80), 9 min (70-9-80), and 20 min (70-20-80) of recovery. Overall Vo(2) kinetics were accelerated relative to control in all conditions except for 40-9-80 and 40-20-80 conditions as a consequence of a reduction in the Vo(2) slow component amplitude; the phase II time constant was not significantly altered with any prior exercise/recovery combination. Exercise tolerance at 80%Delta was improved by 15% and 30% above control in the 70-9-80 and 70-20-80 conditions, respectively, but was impaired by 16% in the 70-3-80 condition. Prior exercise at 40%Delta did not significantly influence exercise tolerance regardless of the recovery duration. These data demonstrate that prior high-intensity exercise ( approximately 70%Delta) can enhance the tolerance to subsequent high-intensity exercise provided that it is coupled with adequate recovery duration (>or=9 min). This combination presumably optimizes the balance between preserving the effects of prior exercise on Vo(2) kinetics and providing sufficient time for muscle homeostasis (e.g., muscle phosphocreatine and H(+) concentrations) to be restored.

  12. Effects of negative air ions on oxygen uptake kinetics, recovery and performance in exercise: a randomized, double-blinded study.

    PubMed

    Nimmerichter, Alfred; Holdhaus, Johann; Mehnen, Lars; Vidotto, Claudia; Loidl, Markus; Barker, Alan R

    2014-09-01

    Limited research has suggested that acute exposure to negatively charged ions may enhance cardio-respiratory function, aerobic metabolism and recovery following exercise. To test the physiological effects of negatively charged air ions, 14 trained males (age: 32 ± 7 years; VO2max: 57 ± 7 mL min(-1) kg(-1)) were exposed for 20 min to either a high-concentration of air ions (ION: 220 ± 30 × 10(3) ions cm(-3)) or normal room conditions (PLA: 0.1 ± 0.06 × 10(3) ions cm(-3)) in an ionization chamber in a double-blinded, randomized order, prior to performing: (1) a bout of severe-intensity cycling exercise for determining the time constant of the phase II VO2 response (τ) and the magnitude of the VO2 slow component (SC); and (2) a 30-s Wingate test that was preceded by three 30-s Wingate tests to measure plasma [adrenaline] (ADR), [nor-adrenaline] (N-ADR) and blood [lactate] (B(Lac)) over 20 min during recovery in the ionization chamber. There was no difference between ION and PLA for the phase II VO2 τ (32 ± 14 s vs. 32 ± 14 s; P = 0.7) or VO2 SC (404 ± 214 mL vs 482 ± 217 mL; P = 0.17). No differences between ION and PLA were observed at any time-point for ADR, N-ADR and B(Lac) as well as on peak and mean power output during the Wingate tests (all P > 0.05). A high-concentration of negatively charged air ions had no effect on aerobic metabolism during severe-intensity exercise or on performance or the recovery of the adrenergic and metabolic responses after repeated-sprint exercise in trained athletes.

  13. Instrument development in the measurement of unsupported arm exercise endurance in normal adult subjects.

    PubMed

    Breslin, E H; Adams, E; Lutz, A; Roy, C

    1993-06-01

    Many daily activities, from basic grooming to employment tasks, require adequate unsupported arm endurance (UAE). We developed an electromechanical device to measure UAE endurance. The purpose of this study was to standardize the instrument for two rates of arm motion, moderate and slow, in 18 normal adult subjects (FEVI = 3.7L +/- .78, FVC = 4.2L +/- .74, FEV1/FVC = 1.1 +/- .08). Exercise endurance limits, and the following metabolic, ventilatory, and sensation responses were determined at rest prior to exercise and at end-exercise limits for both rates of UAE:minute ventilation (Ve), tidal volume (VT), respiratory rate (RR), duty cycle (Ti/Ttot), oxygen uptake (VO2), carbon dioxide production (VCO2), inspiratory flow (VT/Ti), heart rate (HR), and visual analog scale measurements (VAS) of dyspnea (D), respiratory effort (RE), and arm fatigue (AF). Significance increases from baseline rest were shown at the endurance limits for both rates of UAE in: VO2, VCO2, Ve, VT, RR, VT/Ti, HR, VAS-D, VAS-RE, and VAS-AF. There were no changes in Ti/Ttot and SaO2 with UAE. Peak VO2, RR, Ve, VT/Ti, and VAS-D with moderate exercise were significantly greater than slow UAE; and there was a trend increase in peak HR for moderate as opposed to slow rate UAE. Despite these differences, the endurance time between the two rates of UAE were similar. These data provide standards against which UAE in COPD can be evaluated.

  14. Oxygen uptake kinetics of constant-load work - Upright vs. supine exercise

    NASA Technical Reports Server (NTRS)

    Convertino, V. A.; Goldwater, D. J.; Sandler, H.

    1984-01-01

    Supine and upright positions were used in a comparitive study of the effects of constant load exercise on oxygen uptake (VO2), O2 deficit, steady-state VO2 and VO2 following recovery from constant load work. Ten male subjects (36-40 yr.) performed one submaximal exercise test in the supine and one test in the upright position consisting of 5 min rest and 5 min cycle ergometer exercise at 700 kg/min followed by ten minutes of recovery. It is found that the significant difference in VO2 kinetics during exercise in the upright compared to supine position resulted from changes in oxygen transport and utilization mechanisms rather than changes in mechanical efficiency. To the extent that data measured in the supine position can be used to estimate physiological responses to zero gravity, it is suggested that limitation of systemic O2 consumption may be the result of slow rates of oxygen uptake during transient periods of muscular work. Significant reductions in the rate of steady-state VO2 attainment at submaximal work intensities may produce an onset of muscle fatigue and exhaustion.

  15. Patterns of Senescence in Human Cardiovascular Fitness: VO2max in Subsistence and Industrialized Populations

    PubMed Central

    Pisor, Anne C.; Gurven, Michael; Blackwell, Aaron D.; Kaplan, Hillard; Yetish, Gandhi

    2014-01-01

    Objectives This study explores whether cardiovascular fitness levels and senescent decline are similar in the Tsimane of Bolivia and Canadians, as well as other subsistence and industrialized populations. Among Tsimane, we examine whether morbidity predicts lower levels and faster decline of cardiovascular fitness, or whether their lifestyle (e.g., high physical activity) promotes high levels and slow decline. Alternatively, high activity levels and morbidity might counterbalance such that Tsimane fitness levels and decline are similar to those in industrialized populations. Methods Maximal oxygen uptake (VO2max) was estimated using a step test heart rate method for 701 participants. We compared these estimates to the Canadian Health Measures Survey and previous studies in industrialized and subsistence populations. We evaluated whether health indicators and proxies for market integration were associated with VO2max levels and rate of decline for the Tsimane. Results The Tsimane have significantly higher levels of VO2max and slower rates of decline than Canadians; initial evidence suggests differences in VO2max levels between other subsistence and industrialized populations. Low hemoglobin predicts low VO2max for Tsimane women while helminth infection predicts high VO2max for Tsimane men, though results might be specific to the VO2max scaling parameter used. No variables tested interact with age to moderate decline. Conclusions The Tsimane demonstrate higher levels of cardiovascular fitness than industrialized populations, but levels similar to other subsistence populations. The high VO2max of Tsimane is consistent with their high physical activity and few indicators of cardiovascular disease, measured in previous studies. PMID:24022886

  16. Neuromuscular blockade of slow twitch muscle fibres elevates muscle oxygen uptake and energy turnover during submaximal exercise in humans.

    PubMed

    Krustrup, Peter; Secher, Niels H; Relu, Mihai U; Hellsten, Ylva; Söderlund, Karin; Bangsbo, Jens

    2008-12-15

    We tested the hypothesis that a greater activation of fast-twitch (FT) fibres during dynamic exercise leads to a higher muscle oxygen uptake (VO2 ) and energy turnover as well as a slower muscle on-kinetics. Subjects performed one-legged knee-extensor exercise for 10 min at an intensity of 30 W without (CON) and with (CUR) arterial injections of the non-depolarizing neuromuscular blocking agent cisatracurium. In CUR, creatine phosphate (CP) was unaltered in slow twitch (ST) fibres and decreased (P < 0.05) by 28% in FT fibres, whereas in CON, CP decreased (P < 0.05) by 33% and 23% in ST and FT fibres, respectively. From 127 s of exercise, muscle VO2 was higher (P < 0.05) in CUR compared to CON (425 +/- 25 (+/- S.E.M.) versus 332 +/- 30 ml min(-1)) and remained higher (P < 0.05) throughout exercise. Using monoexponential fitting, the time constant of the exercise-induced muscle VO2 response was slower (P < 0.05) in CUR than in CON (55 +/- 6 versus 33 +/- 5 s). During CUR and CON, muscle homogenate CP was lowered (P < 0.05) by 32 and 35%, respectively, and also muscle lactate production was similar in CUR and CON (37.8 +/- 4.1 versus 35.2 +/- 6.2 mmol). Estimated total muscle ATP turnover was 19% higher (P < 0.05) in CUR than in CON (1196 +/- 90 versus 1011 +/- 59 mmol) and true mechanical efficiency was lower (P < 0.05) in CUR than in CON (26.2 +/- 2.0 versus 30.9 +/- 1.5%). In conclusion, the present findings provide evidence that FT fibres are less efficient than ST fibres in vivo at a contraction frequency of 1 Hz, and that the muscle VO2 kinetics is slowed by FT fibre activation.

  17. Velocity, force, power, and Ca2+ sensitivity of fast and slow monkey skeletal muscle fibers

    NASA Technical Reports Server (NTRS)

    Fitts, R. H.; Bodine, S. C.; Romatowski, J. G.; Widrick, J. J.

    1998-01-01

    In this study, we determined the contractile properties of single chemically skinned fibers prepared from the medial gastrocnemius (MG) and soleus (Sol) muscles of adult male rhesus monkeys and assessed the effects of the spaceflight living facility known as the experiment support primate facility (ESOP). Muscle biopsies were obtained 4 wk before and immediately after an 18-day ESOP sit, and fiber type was determined by immunohistochemical techniques. The MG slow type I fiber was significantly smaller than the MG type II, Sol type I, and Sol type II fibers. The ESOP sit caused a significant reduction in the diameter of type I and type I/II (hybrid) fibers of Sol and MG type II and hybrid fibers but no shift in fiber type distribution. Single-fiber peak force (mN and kN/m2) was similar between fiber types and was not significantly different from values previously reported for other species. The ESOP sit significantly reduced the force (mN) of Sol type I and MG type II fibers. This decline was entirely explained by the atrophy of these fiber types because the force per cross-sectional area (kN/m2) was not altered. Peak power of Sol and MG fast type II fiber was 5 and 8.5 times that of slow type I fiber, respectively. The ESOP sit reduced peak power by 25 and 18% in Sol type I and MG type II fibers, respectively, and, for the former fiber type, shifted the force-pCa relationship to the right, increasing the Ca2+ activation threshold and the free Ca2+ concentration, eliciting half-maximal activation. The ESOP sit had no effect on the maximal shortening velocity (Vo) of any fiber type. Vo of the hybrid fibers was only slightly higher than that of slow type I fibers. This result supports the hypothesis that in hybrid fibers the slow myosin heavy chain would be expected to have a disproportionately greater influence on Vo.

  18. Persistent reduced oxygen requirement following blood transfusion during recovery from hemorrhagic shock.

    PubMed

    Haouzi, Philippe; Van de Louw, Andry

    2015-08-15

    Our study intended to determine the effects on oxygen uptake (VO2) of restoring a normal rate of O2 delivery following blood transfusion (BT) after a severe hemorrhage (H). Spontaneously breathing urethane anesthetized rats were bled by removing 20 ml/kg of blood over 30 min. Rats were then infused with their own shed blood 15 min after the end of H. At mid-perfusion, half of the rats received a unique infusion of the decoupling agent 2,4-dinitrophenol (DNP, 6 mg/kg). VO2 and arterial blood pressure (ABP) were continuously measured throughout the study, along with serial determination of blood lactate concentration [La]. Animals were euthanized 45 min after the end of reperfusion; liver and lungs were further analyzed for early expression of oxidative stress gene using RT-PCR. Our bleeding protocol induced a significant decrease in ABP and increase in [La], while VO2 dropped by half. The O2 deficit progressively accumulated during the period of bleeding reached -114 ± 53 ml/kg, just before blood transfusion. Despite the transfusion of blood, a significant O2 deficit persisted (-82 ± 59 ml/kg) 45 min after reperfusion. This slow recovery of VO2 was sped up by DNP injection, leading to a fast recovery of O2 deficit after reperfusion, becoming positive (+460 ± 132 ml/kg) by the end of the protocol, supporting the view that O2 supply is not the main controller of VO2 dynamics after BT. Of note is that DNP also enhanced oxidative stress gene expression (up-regulation of NADPH oxidase 4 in the lung for instance). The mechanism of slow recovery of O2 requirement/demand following BT and the resulting effects on tissues exposed to relatively high O2 partial pressure are discussed. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Physiological responses at five estimates of critical velocity.

    PubMed

    Bull, Anthony J; Housh, Terry J; Johnson, Glen O; Rana, Sharon R

    2008-04-01

    The purpose of this study was to compare critical velocity (CV) estimates from five mathematical models, and to examine the oxygen uptake (VO(2)) and heart rate (HR) responses during treadmill runs at the five estimates of CV. Ten subjects (six males and four females) performed one incremental test to determine maximal oxygen consumption (VO(2max)) and four or five randomly ordered constant-velocity trials on a treadmill for the estimation of CV. Five mathematical models were used to estimate CV for each subject including two linear, two nonlinear, and an exponential model. Up to five randomly ordered runs to exhaustion were performed by each subject at treadmill velocities that corresponded to the five CV estimates, and VO(2) and HR responses were monitored throughout each trial. The 3-parameter, nonlinear (Non-3) model produced CV estimates that were significantly (P < 0.05) less than the other four models. During runs at CV estimates, five subjects did not complete 60 min at the their estimate from the Non-3 model, nine did not complete 60 min at their estimate from the Non-2 model, and no subjects completed 60 min at any estimate from the other three models. The mean HR value (179 +/- 18 beats min(-1), HR(peak)) at the end of runs at CV using the Non-3 model was significantly less than the maximal HR (195 +/- 7 beats min(-1), HR(max)) achieved during the incremental trial to exhaustion. However, mean HR(peak) values from runs at all other CV estimates were not significantly different from HR(max). Furthermore, data indicated that mean HR(peak) values increased during runs at CV estimates from the third minute to the end of exercise for all models, and that these increases in VO(2) (range = 367-458 ml min(-1)) were significantly greater than that typically associated with O(2) drift ( approximately 200 ml min(-1)) for all but the exponential model, indicating a VO(2) slow component associated with CV estimates from four of the five models. However, the mean VO(2) values at the end of exercise during the runs at CV estimates for all five mathematical models were significantly less than the mean VO(2max) value. These results suggest that, in most cases, CV estimated from the five models does not represent a fatigueless task. In addition, the mean CV estimates from the five models varied by 18%, and four of the five mean CV estimates were within the heavy exercise domain. Therefore, CV would not represent the demarcation point between heavy and severe exercise domains.

  20. Cross-validation of oxygen uptake prediction during walking in ambulatory persons with multiple sclerosis.

    PubMed

    Agiovlasitis, Stamatis; Motl, Robert W

    2016-01-01

    An equation for predicting the gross oxygen uptake (gross-VO2) during walking for persons with multiple sclerosis (MS) has been developed. Predictors included walking speed and total score from the 12-Item Multiple Sclerosis Walking Scale (MSWS-12). This study examined the validity of this prediction equation in another sample of persons with MS. Participants were 18 persons with MS with limited mobility problems (42 ± 13 years; 14 women). Participants completed the MSWS-12. Gross-VO2 was measured with open-circuit spirometry during treadmill walking at 2.0, 3.0, and 4.0 mph (0.89, 1.34, and 1.79 m·s(-1)). Absolute percent error was small: 8.3 ± 6.1% , 8.0 ± 5.6% , and 12.2 ± 9.0% at 2.0, 3.0, and 4.0 mph, respectively. Actual gross-VO2 did not differ significantly from predicted gross-VO2 at 2.0 and 3.0 mph, but was significantly higher than predicted gross-VO2 at 4.0 mph (p <  0.001). Bland-Altman plots indicated nearly zero mean difference between actual and predicted gross-VO2 with modest 95% confidence intervals at 2.0 and 3.0 mph, but there was some underestimation at 4.0 mph. Speed and MSWS-12 score provide valid prediction of gross-VO2 during treadmill walking at slow and moderate speeds in ambulatory persons with MS. However, there is a possibility of small underestimation for walking at 4.0 mph.

  1. Influence of angular velocity on vastus lateralis and rectus femoris oxygenation dynamics during knee extension exercises.

    PubMed

    Denis, Romain; Wilkinson, Jennifer; De Vito, Giuseppe

    2011-09-01

    The purpose of this study was to investigate whether changes in angular velocity would alter vastus lateralis (VL) and rectus femoris (RF) oxygenation status during maximal isokinetic knee extension exercises. Eleven recreationally active male participants randomly performed ten maximal knee extensions at 30, 60, 120 and 240° s(-1). Tissue oxygenation index (TOI) and total haemoglobin concentration ([tHb]) were acquired from the VL and RF muscles by means of near-infrared spectroscopy (NIRS). Breath-by-breath pulmonary oxygen consumption (VO(2p)) was recorded throughout the tests. Peak torque and VO(2p) significantly decreased as a function of velocity (P<0·05). Interestingly, RF and VL TOI significantly increased as a function of velocity (P<0·05), whereas [tHb] significantly decreased as a function of velocity (P<0·05). A greater number of muscle fibre recruited at slow velocity, where the torque and VO(2p) were the highest, might explain the lower VL and RF TOI observed herein. Furthermore, the increase in local blood flow (suggested by [tHb] changes) during isokinetic knee extension exercises performed at slow angular velocity might have been induced by a higher intramuscular pressure during the contraction phases as well as a greater microcirculatory vasodilatation during relaxation phases. Implementing slow-velocity isokinetic exercises in rehabilitation or other training programmes could delay the short-term anoxia generated by such exercises and result in muscle metabolism enhancement. © 2011 The Authors. Clinical Physiology and Functional Imaging © 2011 Scandinavian Society of Clinical Physiology and Nuclear Medicine.

  2. Polyoxometalate coordination induced controllable release of quinolone in hybrid film

    NASA Astrophysics Data System (ADS)

    Yang, Fan; Li, Yang; Lv, Yu-Guang; Zhou, Shu-Jing; Li, Si; Gao, Guang-Gang; Liu, Hong

    2018-05-01

    Due to some side effects of quinolones in vivo, it is an urgent issue to extend their new applications in vitro. In this paper, structure-determined vanadium-quinolone functionalized polymolybdates of (NH4)2 [(γ-Mo8O26){VO(CF)2}2] (1) and (NH4)2 [(γ-Mo8O26){VO(NF)2}2] (2) (CF = ciprofloxacin; NF = norfloxacin) have been designed and synthesized. Complex 1 or 2 features a γ-type [Mo8O26]4- polyanion functionalized by two monocapped vanadium-quinolone complexes. Different H-bonds and π···π interactions allow 1 or 2 to form a 2D layered structure at solid state. When complex 1 or 2 is transferred into polyvinyl alcohol (PVA) film, its release rate in solution is lower than that of CF- or NF-PVA film and thus forming a novel quinolone delivery system. This is the first time that slow release effect of quinolone is achieved by polyoxometalate coordination effect. The slow release of 1 or 2 in PVA film is mainly ascribed to the coordination of quinolone with polyoxometalate anions.

  3. Plasma lactate accumulation and distance running performance. 1979.

    PubMed

    Farrell, P A; Wilmore, J H; Coyle, E F; Billing, J E; Costill, D L

    1993-10-01

    Laboratory and field assessments were made on eighteen male distance runners. Performance data were obtained for distances of 3.2, 9.7, 15, 19.3 km (n = 18) and the marathon (n = 13). Muscle fiber composition expressed as percent of slow twitch fibers (%ST), maximal oxygen consumption (VO2max), running economy (VO2 for a treadmill velocity of 268 m/min), and the VO2 and treadmill velocity corresponding to the onset of plasma lactate accumulation (OPLA) were determined for each subject. %ST (R > or equal to .47), VO2max (r > or equal to .83), running economy (r > or equal to .49), VO2 in ml/kg min corresponding to the OPLA (r > or equal to .91) and the treadmill velocity corresponding to OPLA (r > or equal to .91) were significantly (p < .05) related to performance at all distances. Multiple regression analysis showed that the treadmill velocity corresponding to the OPLA was most closely related to performance and the addition of other factors did not significantly raise the multiple R values suggesting that these other variables may interact with the purpose of keeping plasma lactates low during distance races. The slowest and fastest marathoners ran their marathons 7 and 3 m/min faster than their treadmill velocities corresponding to their OPLA which indicates that this relationship is independent of the competitive level of the runner. Runners appear to set a race pace which allows the utilization of the largest possible VO2 which just avoids the exponential rise in plasma lactate.

  4. Tunable VO{sub 2}/Au hyperbolic metamaterial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prayakarao, S.; Noginov, M. A., E-mail: mnoginov@nsu.edu; Mendoza, B.

    2016-08-08

    Vanadium dioxide (VO{sub 2}) is known to have a semiconductor-to-metal phase transition at ∼68 °C. Therefore, it can be used as a tunable component of an active metamaterial. The lamellar metamaterial studied in this work is composed of subwavelength VO{sub 2} and Au layers and is designed to undergo a temperature controlled transition from the optical hyperbolic phase to the metallic phase. VO{sub 2} films and VO{sub 2}/Au lamellar metamaterial stacks have been fabricated and studied in electrical conductivity and optical (transmission and reflection) experiments. The observed temperature-dependent changes in the reflection and transmission spectra of the metamaterials and VO{sub 2}more » thin films are in a good qualitative agreement with theoretical predictions. The demonstrated optical hyperbolic-to-metallic phase transition is a unique physical phenomenon with the potential to enable advanced control of light-matter interactions.« less

  5. Ultrafast photo-induced dynamics across the metal-insulator transition of VO2

    NASA Astrophysics Data System (ADS)

    Wang, Siming; Ramírez, Juan Gabriel; Jeffet, Jonathan; Bar-Ad, Shimshon; Huppert, Dan; Schuller, Ivan K.

    2017-04-01

    The transient reflectivity of VO2 films across the metal-insulator transition clearly shows that with low-fluence excitation, when insulating domains are dominant, energy transfer from the optically excited electrons to the lattice is not instantaneous, but precedes the superheating-driven expansion of the metallic domains. This implies that the phase transition in the coexistence regime is lattice-, not electronically-driven, at weak laser excitation. The superheated phonons provide the latent heat required for the propagation of the optically-induced phase transition. For VO2 this transition path is significantly different from what has been reported in the strong-excitation regime. We also observe a slow-down of the superheating-driven expansion of the metallic domains around the metal-insulator transition, which is possibly due to the competition among several co-existing phases, or an emergent critical-like behavior.

  6. Using broadband spatially resolved NIRS to assess muscle oxygenation during altered running protocols

    NASA Astrophysics Data System (ADS)

    Koukourakis, Georg; Vafiadou, Maria; Steimers, André; Geraskin, Dmitri; Neary, Patrick; Kohl-Bareis, Matthias

    2009-07-01

    We used spatially resolved near-infrared spectroscopy (SRS-NIRS) to assess calf and thigh muscle oxygenation during running on a motor-driven treadmill. Two protocols were used: An incremental speed protocol (velocity = 6 - 12 km/h, ▵v = 2 km/h) was performed in 3 minute stages, while a pacing paradigm modulated step frequency alternatively (2.3 Hz [SLow]; 3.3 Hz [SHigh]) during a constant velocity for 2 minutes each. A SRS-NIRS broadband system (600 - 1000 nm) was used to measure total haemoglobin concentration and oxygen saturation (SO2). An accelerometer was placed on the hip joints to measure limb acceleration through the experiment. The data showed that the calf (SO2 58 to 42%) desaturated to a significantly lower level than the thigh (61 to 54%). During the pacing protocol, SO2 was significantly different between the SLow vs. SHigh trials. Additionally, physiological data as measured by spirometry were different between the SLow vs. SHigh pacing trials (VO2 (2563+/- 586 vs. 2503 +/- 605 mL/min). Significant differences in VO2 at the same workload (speed) indicate alterations in mechanical efficiency. These data suggest that SRS broadband NIRS can be used to discern small changes in muscle oxygenation, making this device useful for metabolic exercise studies in addition to spirometry and movement monitoring by accelerometers.

  7. Carbon quantum dots coated BiVO{sub 4} inverse opals for enhanced photoelectrochemical hydrogen generation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nan, Feng; Shen, Mingrong; Fang, Liang, E-mail: zhkang@suda.edu.cn, E-mail: lfang@suda.edu.cn

    Carbon quantum dots (CQDs) coated BiVO{sub 4} inverse opal (io-BiVO{sub 4}) structure that shows dramatic improvement of photoelectrochemical hydrogen generation has been fabricated using electrodeposition with a template. The io-BiVO{sub 4} maximizes photon trapping through slow light effect, while maintaining adequate surface area for effective redox reactions. CQDs are then incorporated to the io-BiVO{sub 4} to further improve the photoconversion efficiency. Due to the strong visible light absorption property of CQDs and enhanced separation of the photoexcited electrons, the CQDs coated io-BiVO{sub 4} exhibit a maximum photo-to-hydrogen conversion efficiency of 0.35%, which is 6 times higher than that of themore » pure BiVO{sub 4} thin films. This work is a good example of designing composite photoelectrode by combining quantum dots and photonic crystal.« less

  8. SnO2@C@VO2 Composite Hollow Nanospheres as an Anode Material for Lithium-Ion Batteries.

    PubMed

    Guo, Wenbin; Wang, Yong; Li, Qingyuan; Wang, Dongxia; Zhang, Fanchao; Yang, Yiqing; Yu, Yang

    2018-05-02

    Porous SnO 2 @C@VO 2 composite hollow nanospheres were ingeniously constructed through the combination of layer-by-layer deposition and redox reaction. Moreover, to optimize the electrochemical properties, SnO 2 @C@VO 2 composite hollow nanospheres with different contents of the external VO 2 were also studied. On the one hand, the elastic and conductive carbon as interlayer in the SnO 2 @C@VO 2 composite can not only buffer the huge volume variation during repetitive cycling but also effectively improve electronic conductivity and enhance the utilizing rate of SnO 2 and VO 2 with high theoretical capacity. On the other hand, hollow nanostructures of the composite can be consolidated by the multilayered nanocomponents, resulting in outstanding cyclic stability. In virtue of the above synergetic contribution from individual components, SnO 2 @C@VO 2 composite hollow nanospheres exhibit a large initial discharge capacity (1305.6 mAhg -1 ) and outstanding cyclic stability (765.1 mAhg -1 after 100 cycles). This design of composite hollow nanospheres may be extended to the synthesis of other nanomaterials for electrochemical energy storage.

  9. Prime Contract Awards Over $25,000 by Major System, Contractor and State, FY83.

    DTIC Science & Technology

    1983-01-01

    SERVICES 3,074 VO R513 STUDIES/FEASIBILITY - NON- CONSTRUCTION 125 VO T013 TECHNICAL WRITING 1,347 VO 1560 AIRFRAME STRUCTURAL COMPONENTS 6,825 VO 1620...INC NCAR 1670 PARACHUTES RECOVERY SYS AND TIE DOWN EQ 49 ROCKWELL INTERNATIONAL CORP CALIF Y19 CONSTR: CONSTRUCTION /OTHER AIRFIELD STRUCTURES 28,480...INC NEW Y 1560 AIRFRAME STRUCTURAL COMPONENTS 36 GANAR INDUSTRIES I NC CALIF 1680 MISCL AIRCRAFT ACCESSORIES COMPONENTS 180 GARRETT CONSTRUCTION CO

  10. Familial aggregation of VO(2max) response to exercise training: results from the HERITAGE Family Study.

    PubMed

    Bouchard, C; An, P; Rice, T; Skinner, J S; Wilmore, J H; Gagnon, J; Pérusse, L; Leon, A S; Rao, D C

    1999-09-01

    The aim of this study was to test the hypothesis that individual differences in the response of maximal O(2) uptake (VO(2max)) to a standardized training program are characterized by familial aggregation. A total of 481 sedentary adult Caucasians from 98 two-generation families was exercise trained for 20 wk and was tested for VO(2max) on a cycle ergometer twice before and twice after the training program. The mean increase in VO(2max) reached approximately 400 ml/min, but there was considerable heterogeneity in responsiveness, with some individuals experiencing little or no gain, whereas others gained >1.0 l/min. An ANOVA revealed that there was 2.5 times more variance between families than within families in the VO(2max) response variance. With the use of a model-fitting procedure, the most parsimonious models yielded a maximal heritability estimate of 47% for the VO(2max) response, which was adjusted for age and sex with a maternal transmission of 28% in one of the models. We conclude that the trainability of VO(2max) is highly familial and includes a significant genetic component.

  11. Effects of training on muscle O2 transport at VO2max

    NASA Technical Reports Server (NTRS)

    Roca, J.; Agusti, A. G.; Alonso, A.; Poole, D. C.; Viegas, C.; Barbera, J. A.; Rodriguez-Roisin, R.; Ferrer, A.; Wagner, P. D.

    1992-01-01

    To quantify the relative contributions of convective and peripheral diffusive components of O2 transport to the increase in leg O2 uptake (VO2leg) at maximum O2 uptake (VO2max) after 9 wk of endurance training, 12 sedentary subjects (age 21.8 +/- 3.4 yr, VO2max 36.9 +/- 5.9 ml.min-1.kg-1) were studied. VO2max, leg blood flow (Qleg), and arterial and femoral venous PO2, and thus VO2leg, were measured while the subjects breathed room air, 15% O2, and 12% O2. The sequence of the three inspirates was balanced. After training, VO2max and VO2leg increased at each inspired O2 concentration [FIO2; mean over the 3 FIO2 values 25.2 +/- 17.8 and 36.5 +/- 33% (SD), respectively]. Before training, VO2leg and mean capillary PO2 were linearly related through the origin during hypoxia but not during room air breathing, suggesting that, at 21% O2, VO2max was not limited by O2 supply. After training, VO2leg and mean capillary PO2 at each FIO2 fell along a straight line with zero intercept, just as in athletes (Roca et al. J. Appl. Physiol. 67: 291-299, 1989). Calculated muscle O2 diffusing capacity (DO2) rose 34% while Qleg increased 19%. The relatively greater rise in DO2 increased the DO2/Qleg, which led to 9.9% greater O2 extraction. By numerical analysis, the increase in Qleg alone (constant DO2) would have raised VO2leg by 35 ml/min (mean), but that of DO2 (constant Qleg) would have increased VO2leg by 85 ml/min, more than twice as much. The sum of these individual effects (120 ml/min) was less (P = 0.013) than the observed rise of 164 ml/min (mean). This synergism (explained by the increase in DO2/Qleg) seems to be an important contribution to increases in VO2max with training.

  12. A Thermal Diode Based on Nanoscale Thermal Radiation.

    PubMed

    Fiorino, Anthony; Thompson, Dakotah; Zhu, Linxiao; Mittapally, Rohith; Biehs, Svend-Age; Bezencenet, Odile; El-Bondry, Nadia; Bansropun, Shailendra; Ben-Abdallah, Philippe; Meyhofer, Edgar; Reddy, Pramod

    2018-05-23

    In this work we demonstrate thermal rectification at the nanoscale between doped Si and VO 2 surfaces. Specifically, we show that the metal-insulator transition of VO 2 makes it possible to achieve large differences in the heat flow between Si and VO 2 when the direction of the temperature gradient is reversed. We further show that this rectification increases at nanoscale separations, with a maximum rectification coefficient exceeding 50% at ∼140 nm gaps and a temperature difference of 70 K. Our modeling indicates that this high rectification coefficient arises due to broadband enhancement of heat transfer between metallic VO 2 and doped Si surfaces, as compared to narrower-band exchange that occurs when VO 2 is in its insulating state. This work demonstrates the feasibility of accomplishing near-field-based rectification of heat, which is a key component for creating nanoscale radiation-based information processing devices and thermal management approaches.

  13. Relation of systemic and local muscle exercise capacity to skeletal muscle characteristics in men with congestive heart failure

    NASA Technical Reports Server (NTRS)

    Massie, B. M.; Simonini, A.; Sahgal, P.; Wells, L.; Dudley, G. A.

    1996-01-01

    OBJECTIVES. The present study was undertaken to further characterize changes in skeletal muscle morphology and histochemistry in congestive heart failure and to determine the relation of these changes to abnormalities of systemic and local muscle exercise capacity. BACKGROUND. Abnormalities of skeletal muscle appear to play a role in the limitation of exercise capacity in congestive heart failure, but information on the changes in muscle morphology and biochemistry and their relation to alterations in muscle function is limited. METHODS. Eighteen men with predominantly mild to moderate congestive heart failure (mean +/- SEM New York Heart Association functional class 2.6 +/- 0.2, ejection fraction 24 +/- 2%) and eight age- and gender-matched sedentary control subjects underwent measurements of peak systemic oxygen consumption (VO2) during cycle ergometry, resistance to fatigue of the quadriceps femoris muscle group and biopsy of the vastus lateralis muscle. RESULTS. Peak VO2 and resistance to fatigue were lower in the patients with heart failure than in control subjects (15.7 +/- 1.2 vs. 25.1 +/- 1.5 ml/min-kg and 63 +/- 2% vs. 85 +/- 3%, respectively, both p < 0.001). Patients had a lower proportion of slow twitch, type I fibers than did control subjects (36 +/- 3% vs. 46 +/- 5%, p = 0.048) and a higher proportion of fast twitch, type IIab fibers (18 +/- 3% vs. 7 +/- 2%, p = 0.004). Fiber cross-sectional area was smaller, and single-fiber succinate dehydrogenase activity, a mitochondrial oxidative marker, was lower in patients (both p < or = 0.034). Likewise, the ratio of average fast twitch to slow twitch fiber cross-sectional area was lower in patients (0.780 +/- 0.06 vs. 1.05 +/- 0.08, p = 0.019). Peak VO2 was strongly related to integrated succinate dehydrogenase activity in patients (r = 0.896, p = 0.001). Peak VO2, resistance to fatigue and strength also correlated significantly with several measures of fiber size, especially of fast twitch fibers, in patients. None of the skeletal muscle characteristics examined correlated with exercise capacity in control subjects. CONCLUSIONS. These results indicate that congestive heart failure is associated with changes in the characteristics of skeletal muscle and local as well as systemic exercise performance. There are fewer slow twitch fibers, smaller fast twitch fibers and lower succinate dehydrogenase activity. The latter finding suggests that mitochondrial content of muscle is reduced in heart failure and that impaired aerobic-oxidative capacity may play a role in the limitation of systemic exercise capacity.

  14. Open porous BiVO{sub 4} nanomaterials: Electronspinning fabrication and enhanced visible light photocatalytic activity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Mengyan; Xi, Xin; Gong, Cairong, E-mail: gcr@tju.edu.cn

    2016-02-15

    Highlights: • BiVO{sub 4} nanofibers were successfully fabricated by electrospinning method. • PVP was used to adjust the viscosity and increase spinnability of the electrospinning sol. • BiVO{sub 4} nanofibers were used for the degradation of MB. • Compared to the submicron sized BiVO4, BiVO{sub 4} nanofibers show superior photocatalytic activity. - Abstract: Witnessed by X-ray powder diffraction (XRD), Raman, scanning electron microscopy (SEM) and transmission electron microscopy (TEM) studies, BiVO{sub 4} nanofibers and porous nanostructures were successfully fabricated by electrospinning method using NH{sub 4}VO{sub 3} and Bi(NO{sub 3}){sub 3} as starting materials. Polyvinylpyrrolidinone (PVP) was used to tune themore » viscosity and spinnability of the electrospinning sol. The slow decomposition and combustion of PVP matrix prevented rapid crystal growth of BiVO{sub 4} nanostructures leading to considerably small crystallite size (approximately 19.1–28.3 nm) with less surface defects after two hours calcination at varying temperatures. This paid great tributes to the superior visible light photocatalytic activity when compared to the submicron sized BiVO{sub 4} prepared in the absence of PVP.« less

  15. VO(2max) and Microgravity Exposure: Convective versus Diffusive O(2) Transport.

    PubMed

    Ade, Carl J; Broxterman, Ryan M; Barstow, Thomas J

    2015-07-01

    Exposure to a microgravity environment decreases the maximal rate of O2 uptake (VO(2max)) in healthy individuals returning to a gravitational environment. The magnitude of this decrease in VO(2max) is, in part, dependent on the duration of microgravity exposure, such that long exposure may result in up to a 38% decrease in VO(2max). This review identifies the components within the O(2) transport pathway that determine the decrease in postmicrogravity VO(2max) and highlights the potential contributing physiological mechanisms. A retrospective analysis revealed that the decline in VO(2max) is initially mediated by a decrease in convective and diffusive O(2) transport that occurs as the duration of microgravity exposure is extended. Mechanistically, the attenuation of O(2) transport is the combined result of a deconditioning across multiple organ systems including decreases in total blood volume, red blood cell mass, cardiac function and mass, vascular function, skeletal muscle mass, and, potentially, capillary hemodynamics, which become evident during exercise upon re-exposure to the head-to-foot gravitational forces of upright posture on Earth. In summary, VO(2max) is determined by the integration of central and peripheral O(2) transport mechanisms, which, if not maintained during microgravity, will have a substantial long-term detrimental impact on space mission performance and astronaut health.

  16. Infrared spectra of the ammonium ion in ammonium metavanadate NH 4VO 3

    NASA Astrophysics Data System (ADS)

    de Waal, D.; Heyns, A. M.; Range, K.-J.; Eglmeier, C.

    The ND stretching modes of isotopically dilute NH 3D + ions in NH 4VO 3 are in agreement with the predicted splitting into C s, C s and C1(2) components under C s site symmetry for the NH +4 ion. The three bands observed represent the three NH bonding distances in the crystal, and the position, shape and low temperature behaviour of each band confirms the existence of two types of hydrogen bonding in NH 4VO 3. The low temperature infrared modes of NH +4 and ND +4 in NH 4VO 3 and ND 4VO 3, respectively, can be assigned under space group Pbcm. Temperature dependence of these modes also reflects the presence of both normal and bifurcated hydrogen bonds in NH 4VO 3.

  17. Enhanced photoelectrochemical and photocatalytic activity in visible-light-driven Ag/BiVO{sub 4} inverse opals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fang, Liang, E-mail: lfang@suda.edu.cn, E-mail: dawei.cao@tu-ilmenau.de; Nan, Feng; Yang, Ying

    2016-02-29

    BiVO{sub 4} photonic crystal inverse opals (io-BiVO{sub 4}) with highly dispersed Ag nanoparticles (NPs) were prepared by the nanosphere lithography method combining the pulsed current deposition method. The incorporation of the Ag NPs can significantly improve the photoelectrochemical and photocatalytic activity of BiVO{sub 4} inverse opals in the visible light region. The photocurrent density of the Ag/io-BiVO{sub 4} sample is 4.7 times higher than that of the disordered sample without the Ag NPs, while the enhancement factor of the corresponding kinetic constant in photocatalytic experiment is approximately 3. The improved photoelectrochemical and photocatalytic activity is benefited from two reasons: onemore » is the enhanced light harvesting owing to the coupling between the slow light and localized surface plasmon resonance effect; the other is the efficient separation of charge carriers due to the Schottky barriers.« less

  18. Influence of VO2+ ions on structural and optical properties of potassium succinate-succinic acid single crystal for non-linear optical applications

    NASA Astrophysics Data System (ADS)

    Juliet sheela, K.; Subramanian, P.

    2018-04-01

    A transparent and good optical quality semi organic single crystal of vanadium doped potassium succinate-succinic acid (KSSA) was synthesized by slow evaporation technique at room temperature. The structural perfection was supported by the powder XRD of the KSSA-VO2+ single crystal. Optical behavior of the material was discovered from the absorption and transmission spectra of UV-vis-NIR characterization. Functional group and presence of metal ion in the specimen are depicted from FTIR traces. From the photoluminescence studies, emission of wavelength in the violet region (418 nm) at the excitation of 243 nm could be ascertained. EDAX, SEM measurements identify presence of elements and pictures the step-line growth and the imperfection presents in the grown crystal. EPR analysis extracts the information about the local site symmetry around the impurity ion, molecular orbital coefficients, admixture coefficients and ground state wave function of VO2+ doped KSSA single crystal. Second harmonic generation (SHG) efficiency of the grown crystal was investigated to explore the NLO characteristic of the material.

  19. Probing interfacial energetics and charge transfer kinetics in semiconductor nanocomposites: New insights into heterostructured TiO 2/BiVO 4 photoanodes

    DOE PAGES

    Hess, Lucas H.; Cooper, Jason K.; Loiudice, Anna; ...

    2017-02-28

    Heterostructured nanocomposites offer promise for creating systems exhibiting functional properties that exceed those of the isolated components. For solar energy conversion, such combinations of semiconducting nanomaterials can be used to direct charge transfer along pathways that reduce recombination and promote efficient charge extraction. However, interfacial energetics and associated kinetic pathways often differ significantly from predictions derived from the characteristics of pure component materials, particularly at the nanoscale. Here, the emergent properties of TiO 2/BiVO 4 nanocomposite photoanodes are explored using a combination of X-ray and optical spectroscopies, together with photoelectrochemical (PEC) characterization. Application of these methods to both the puremore » components and the fully assembled nanocomposites reveals unpredicted interfacial energetic alignment, which promotes ultrafast injection of electrons from BiVO 4 into TiO 2. Physical charge separation yields extremely long-lived photoexcited states and correspondingly enhanced photoelectrochemical functionality. This work highlights the importance of probing emergent interfacial energetic alignment and kinetic processes for understanding mechanisms of solar energy conversion in complex nanocomposites.« less

  20. Microwave assisted growth of nanorods vanadium dioxide VO2 (R): structural and electrical properties

    NASA Astrophysics Data System (ADS)

    Derkaoui, I.; Khenfouch, M.; Mothudi, B. M.; Moloi, S. J.; Zorkani, I.; Jorio, A.; Maaza, M.

    2018-03-01

    Nanostructured metal oxides have attracted a lot of attention recently owning to their unique structural advantages and demonstrated promising chemical and physical properties for various applications. In this study, we report the structural and electrical properties of vanadium dioxide VO2 (R) prepared via a single reaction microwave (SRC) synthesis. Our results are revealing that the components of VO2 (R) films have a rod-like shape with a uniform size distribution. The nanorods with very smooth and flat surfaces have a typical length of up to 2μm and a width of about several nanometers. The structural investigations reveal the high crystallinity of VO2 (R) ensuring good electrical contact and showing a high conductivity as a function of temperature. This synthesis method provides a new simple route to fabricate one-dimensional nanostructured metal oxides which is suitable for a large field of applications especially for smart windows.

  1. Preparation and modification of VO2 thin film on R-sapphire substrate by rapid thermal process

    NASA Astrophysics Data System (ADS)

    Zhu, Nai-Wei; Hu, Ming; Xia, Xiao-Xu; Wei, Xiao-Ying; Liang, Ji-Ran

    2014-04-01

    The VO2 thin film with high performance of metal-insulator transition (MIT) is prepared on R-sapphire substrate for the first time by magnetron sputtering with rapid thermal process (RTP). The electrical characteristic and THz transmittance of MIT in VO2 film are studied by four-point probe method and THz time domain spectrum (THz-TDS). X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and search engine marketing (SEM) are employed to analyze the crystalline structure, valence state, surface morphology of the film. Results indicate that the properties of VO2 film which is oxidized from the metal vanadium film in oxygen atmosphere are improved with a follow-up RTP modification in nitrogen atmosphere. The crystallization and components of VO2 film are improved and the film becomes compact and uniform. A better phase transition performance is shown that the resistance changes nearly 3 orders of magnitude with a 2-°C hysteresis width and the THz transmittances are reduced by 64% and 60% in thermal and optical excitation respectively.

  2. The S factor--a new derived hemodynamic oxygenation parameter--a useful tool for simplified mathematical modeling of global problems of oxygen transport.

    PubMed

    Farrell, K; Wasser, T

    1997-01-01

    We describe a new derived hemodynamic oxygenation parameter, the S factor (S). The factor is based on oxygen delivery and oxygen consumption and can range from -3 to 1. It allows simplified mathematical modeling of clinical problems of oxygen transport and can be applied to many clinical situations. A new hemodynamic oxygenation parameter, the S factor (S), is introduced as an aid to mathematical modeling. It is defined as follows: [formula: see text] (DO2 = oxygen delivery, VO2 = oxygen consumption) S can theoretically vary from -3 (DO2 = VO2) to +1 (VO2 = 0). When DO2/VO2 = 4 (ie. OER = 0.25), S = 0. An S < 0 implies utilization of reserve oxygen transport capacity. An S > 0 implies increased oxygen delivery in relation to oxygen consumption (ie. "shunted oxygen delivery"). By algebraic manipulation and substitution of the components of DO2 into Equation 1: DO2 = Q x Ca x 10 DO2 = Q [(Hb)(Sat)(1.36) + PaO2(.0031)] 10 (2) the following equations can be derived: [formula: see text] [formula: see text] Ca - Cv (Ca = arterial content, Cv = venous content) can be determined by substituting components of oxygen consumption: VO2 = Q (Ca - Cv) x 10 (5) into equation 1 and solving for Ca - Cv. [formula: see text] Equation 6 can be simplified to: [formula: see text] A previously defined relationship between mixed venous PO2 (PvO2) and DO2/VO2 (where calculated P50 is 26.6 +/- 1.0) can be used to modify S in a clinically relevant manner. PvO2 = 5.44D O2/VO2 + 18.16 (8) The relationship between S and PvO2 can be defined by substituting Equation 4 into Equation 1 and solving for PvO2 PvO2 = [21.76/(1-S)] + 18.16 (9) As an example, at a PvO2 of 28 torr (anaerobic threshold), S = -1.2. The relationship between PvO2 and S is shown in Figure 1. S, which can also be defined as 1-4(VO2/DO2) or 1-4(OER), is a useful tool for mathematical modeling of global problems of oxygen transport because the previously derived equations with the S value allow the components of oxygen transport to be interrelated in a clinically relevant manner. Additional advantages of using S in mathematical modeling are: 1. Conceptually it 'fits' in that in regards to the sign (+ or -), as a -S implies utilization of reserve oxygen transport capacity and a +S implies wasted or excess oxygen delivery (shunted). 2. These concepts are easily quantified using the S factor. 3. It 'spreads out' the difference between values for parameters (OER or S) integrating components of oxygen transport, ie. in the 'normal state' regarding oxygen transport, OER = 0.25 and S = 0. At the anaerobic threshold (PvO2 = 28 torr), OER = 0.55 and S = -1.2. Thus, the change in OER from 'normal state' to anaerobic threshold is 0.3 (0.55-0.25) and the change in S is 1.2. This represents a four-fold increase. Four examples of mathematical modeling of global problems of oxygen transport using the S factor are described below.

  3. Pulsed laser-deposited VO2 thin films on Pt layers

    NASA Astrophysics Data System (ADS)

    Sakai, Joe; Zaghrioui, Mustapha; Ta Phuoc, Vinh; Roger, Sylvain; Autret-Lambert, Cécile; Okimura, Kunio

    2013-03-01

    VO2 films were deposited on Pt (111)/TiO2/SiO2/Si (001) substrates by means of a pulsed laser deposition technique. An x-ray diffraction peak at 2θ = 39.9° was deconvoluted into two pseudo-Voigt profiles of Pt (111) and VOx-originated components. The VOx diffraction peak was more obvious in a VOx/Pt (111)/Al2O3 (0001) sample, having a narrower width compared with a VO2/Al2O3 (0001) sample. Temperature-controlled Raman spectroscopy for the VOx/Pt/TiO2/SiO2/Si sample has revealed the monoclinic VO2 phase at low temperature and the structural phase transition at about 72 °C in a heating process. The electronic conductive nature at the high temperature phase was confirmed by near normal incidence infrared reflectivity measurements. Out-of-plane current-voltage characteristics showed an electric field-induced resistance switching at a voltage as low as 0.2 V for a 50 nm-thick film. A survey of present and previous results suggests an experimental law that the transition voltage of VO2 is proportional to the square root of the electrodes distance.

  4. Cardiorespiratory fitness and components of the metabolic syndrome in sedentary men.

    PubMed

    Riou, Marie-Eve; Pigeon, Etienne; St-Onge, Josée; Tremblay, Angelo; Marette, André; Weisnagel, John; Joanisse, Denis R

    2009-01-01

    To investigate the relationships between fitness and components of the metabolic syndrome in sedentary men. 39 subjects (34-53 years) were evaluated for fitness (VO(2max)) and anthropometric, metabolic, and skeletal muscle phenotypes. VO(2max) was assessed on a bicycle ergometer whereas other variables were obtained from an oral glucose tolerance test (OGTT), hydrostatic weighing, and a muscle biopsy. Pearson and partial correlations adjusted for fat mass (FM), waist circumference (WC), muscle enzyme activities (citrate synthase (CS), cytochrome c oxidase (COX)), and capillary density were used to investigate the independent relationships be tween variables. Negative correlations between VO(2max) and WC as well as blood pressure and OGTT test were observed. When adjusted for FM, correlations remained between VO(2max) and WC (r = -0.46, p < 0.01) and systolic blood pressure (r = -0.35, p < 0.05). When adjusted for WC and CS activity, all correlations were lost except for high-sensitivity C-reactive protein (hs-CRP) (r = -0.34, p < 0.05) which remained when adjusted for CS activity. Adjustment for COX activity failed to remove correlations with hs-CRP (r = -0.36, p < 0.05), age (r = 0.34, p < 0.05), WC (r = -0.35, p < 0.05), and blood pressure. Negative correlations persisted when fitness was adjusted for the mean number of capillaries. The effects of fitness on components of the metabolic syndrome in sedentary men are explained by abdominal obesity and muscle phenotypes.

  5. 31P Magnetic Resonance Spectroscopy Assessment of Muscle Bioenergetics as a Predictor of Gait Speed in the Baltimore Longitudinal Study of Aging.

    PubMed

    Choi, Seongjin; Reiter, David A; Shardell, Michelle; Simonsick, Eleanor M; Studenski, Stephanie; Spencer, Richard G; Fishbein, Kenneth W; Ferrucci, Luigi

    2016-12-01

    Aerobic fitness and muscle bioenergetic capacity decline with age; whether such declines explain age-related slowing of walking speed is unclear. We hypothesized that muscle energetics and aerobic capacity are independent correlates of walking speed in simple and challenging performance tests and that they account for the observed age-related decline in walking speed in these same tests. Muscle bioenergetics was assessed as postexercise recovery rate of phosphocreatine (PCr), k PCr , using phosphorus magnetic resonance spectroscopy ( 31 P-MRS) in 126 participants (53 men) of the Baltimore Longitudinal Study of Aging aged 26-91 years (mean = 72 years). Four walking tasks were administered-usual pace over 6 m and 150 seconds and fast pace over 6 m and 400 m. Separately, aerobic fitness was assessed as peak oxygen consumption (peak VO 2 ) using a graded treadmill test. All gait speeds, k PCr , and peak VO 2 were lower with older age. Independent of age, sex, height, and weight, both k PCr and peak VO 2 were positively and significantly associated with fast pace and long distance walking but only peak VO 2 and not k PCr was significantly associated with usual gait speed over 6 m. Both k PCr and peak VO 2 substantially attenuated the association between age and gait speed for all but the least stressful walking task of 6 m at usual pace. Muscle bioenergetics assessed using 31 P-MRS is highly correlated with walking speed and partially explains age-related poorer performance in fast and long walking tasks. Published by Oxford University Press on behalf of The Gerontological Society of America 2016. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  6. Modular VO oriented Java EE service deployer

    NASA Astrophysics Data System (ADS)

    Molinaro, Marco; Cepparo, Francesco; De Marco, Marco; Knapic, Cristina; Apollo, Pietro; Smareglia, Riccardo

    2014-07-01

    The International Virtual Observatory Alliance (IVOA) has produced many standards and recommendations whose aim is to generate an architecture that starts from astrophysical resources, in a general sense, and ends up in deployed consumable services (that are themselves astrophysical resources). Focusing on the Data Access Layer (DAL) system architecture, that these standards define, in the last years a web based application has been developed and maintained at INAF-OATs IA2 (Italian National institute for Astrophysics - Astronomical Observatory of Trieste, Italian center of Astronomical Archives) to try to deploy and manage multiple VO (Virtual Observatory) services in a uniform way: VO-Dance. However a set of criticalities have arisen since when the VO-Dance idea has been produced, plus some major changes underwent and are undergoing at the IVOA DAL layer (and related standards): this urged IA2 to identify a new solution for its own service layer. Keeping on the basic ideas from VO-Dance (simple service configuration, service instantiation at call time and modularity) while switching to different software technologies (e.g. dismissing Java Reflection in favour of Enterprise Java Bean, EJB, based solution), the new solution has been sketched out and tested for feasibility. Here we present the results originating from this test study. The main constraints for this new project come from various fields. A better homogenized solution rising from IVOA DAL standards: for example the new DALI (Data Access Layer Interface) specification that acts as a common interface system for previous and oncoming access protocols. The need for a modular system where each component is based upon a single VO specification allowing services to rely on common capabilities instead of homogenizing them inside service components directly. The search for a scalable system that takes advantage from distributed systems. The constraints find answer in the adopted solutions hereafter sketched. The development of the new system using Java Enterprise technologies can better benefit from existing libraries to build up the single tokens implementing the IVOA standards. Each component can be built from single standards and each deployed service (i.e. service components instantiations) can consume the other components' exposed methods and services without the need of homogenizing them in dedicated libraries. Scalability can be achieved in an easier way by deploying components or sets of services on a distributed environment and using JNDI (Java Naming and Directory Interface) and RMI (Remote Method Invocation) technologies. Single service configuration will not be significantly different from the VO-Dance solution given that Java class instantiation that benefited from Java Reflection will only be moved to Java EJB pooling (and not, e.g. embedded in bundles for subsequent deployment).

  7. VO2 Kinetics in All-out Arm Stroke, Leg Kick and Whole Stroke Front Crawl 100-m Swimming.

    PubMed

    Rodríguez, F A; Lätt, E; Jürimäe, J; Maestu, J; Purge, P; Rämson, R; Haljaste, K; Keskinen, K L; Jürimäe, T

    2016-03-01

    The VO2 response to extreme-intensity exercise and its relationship with sports performance are largely unexplored. This study investigated the pulmonary VO2 kinetics during all-out 100-m front crawl whole stroke swimming (S), arm stroke (A) and leg kick (L). 26 male and 10 female competitive swimmers performed an all-out S trial followed by A and L of equal duration in random order. Breath-by-breath VO2 was measured using a snorkel attached to a portable gas analyzer. Mean (±SD) primary component parameters and peak blood lactate (Lapeak) during S, A, and L were, respectively: time delay (s), 14.2 ± 4.7, 14.3 ± 4.5, 15.6 ± 5.1; amplitude (ml·kg(-1)·min(-1)), 46.8 ± 6.1, 37.3 ± 6.9, 41.0 ± 4.7; time constant (τ, s): 9.2 ± 3.2, 12.4 ± 4.7, 10.1 ± 3.2; Lapeak (mmol·l(-1)), 6.8 ± 3.1, 6.3 ± 2.5, 7.9 ± 2.8. During A and L respectively, 80% and 87% of amplitude in S was reached, whereas A+L were 68% greater than in S. 100-m performance was associated to shorter cardiodynamic phase and greater VO2 amplitude and Lapeak (accounting up to 61% of performance variance), but not to τ. We conclude that (i) VO2 gain was proportional to exercise intensity and muscle mass involved, (ii) kicking is metabolically less efficient, and (iii) the main limiting factor of peak VO2 appears to be O2 delivery and not muscle extraction. © Georg Thieme Verlag KG Stuttgart · New York.

  8. The effect of Iron Supplying on VO2 MAX and Haematology Parameter on Menstrual Woman

    NASA Astrophysics Data System (ADS)

    Nailuvar Sinaga, Rika; Sari Harahap, Novita; Mediyana Sari, Rima

    2018-03-01

    One of the supporting factors to have good aerobic endurance requires high VO2 max levels supported by good quality and quantity level of Haematology parameter especially such as erythrocytes, hematocrit and hemoglobin. One of the components in hemoglobin is iron which functions as theoxygen transport to parts of all body required in the process of metabolism. The objective of this research was to find out the difference between VO2 Max and Haematology parameter between iron supplying and no iron supplyingonmenstrual woman. The type of this research is quasi experimental research with non-randomized control group Pretest-Postest Design. The subjectsarethe studentsat faculty of Sports Sciences, Medan State University with the criteria of female gender, monthly regular menstrual cycle, having the level of health and the level of training, willing to be a sample by filling out informed consent. The total number of research subjectsis twenty students, divided into two groups namely the treatment group and the control group. The hematology parameter was measuredby Haemotology analyzer and VO2 Max was measured by multi-stage run. The result showed that there was a significant effect of iron supplyingon the increase of erythrocyte level on menstrual women, hemotocrit, haemoglobin and an increase in VO2 Max. Iron supplying on menstrual woman has the effect on the increase of erythrocyte, hematocrit, hemoglobin level and VO2 Max

  9. Type 2 diabetes mellitus and exercise impairment.

    PubMed

    Reusch, Jane E B; Bridenstine, Mark; Regensteiner, Judith G

    2013-03-01

    Limitations in physical fitness, a consistent finding in individuals with both type I and type 2 diabetes mellitus, correlate strongly with cardiovascular and all-cause mortality. These limitations may significantly contribute to the persistent excess cardiovascular mortality affecting this group. Exercise impairments in VO2 peak and VO2 kinetics manifest early on in diabetes, even with good glycemic control and in the absence of clinically apparent complications. Subclinical cardiac dysfunction is often present but does not fully explain the observed defect in exercise capacity in persons with diabetes. In part, the cardiac limitations are secondary to decreased perfusion with exercise challenge. This is a reversible defect. Similarly, in the skeletal muscle, impairments in nutritive blood flow correlate with slowed (or inefficient) exercise kinetics and decreased exercise capacity. Several correlations highlight the likelihood of endothelial-specific impairments as mediators of exercise dysfunction in diabetes, including insulin resistance, endothelial dysfunction, decreased myocardial perfusion, slowed tissue hemoglobin oxygen saturation, and impairment in mitochondrial function. Both exercise training and therapies targeted at improving insulin sensitivity and endothelial function improve physical fitness in subjects with type 2 diabetes. Optimization of exercise functions in people with diabetes has implications for diabetes prevention and reductions in mortality risk. Understanding the molecular details of endothelial dysfunction in diabetes may provide specific therapeutic targets for the remediation of this defect. Rat models to test this hypothesis are under study.

  10. Coding of Velocity Storage in the Vestibular Nuclei.

    PubMed

    Yakushin, Sergei B; Raphan, Theodore; Cohen, Bernard

    2017-01-01

    Semicircular canal afferents sense angular acceleration and output angular velocity with a short time constant of ≈4.5 s. This output is prolonged by a central integrative network, velocity storage that lengthens the time constants of eye velocity. This mechanism utilizes canal, otolith, and visual (optokinetic) information to align the axis of eye velocity toward the spatial vertical when head orientation is off-vertical axis. Previous studies indicated that vestibular-only (VO) and vestibular-pause-saccade (VPS) neurons located in the medial and superior vestibular nucleus could code all aspects of velocity storage. A recently developed technique enabled prolonged recording while animals were rotated and received optokinetic stimulation about a spatial vertical axis while upright, side-down, prone, and supine. Firing rates of 33 VO and 8 VPS neurons were studied in alert cynomolgus monkeys. Majority VO neurons were closely correlated with the horizontal component of velocity storage in head coordinates, regardless of head orientation in space. Approximately, half of all tested neurons (46%) code horizontal component of velocity in head coordinates, while the other half (54%) changed their firing rates as the head was oriented relative to the spatial vertical, coding the horizontal component of eye velocity in spatial coordinates. Some VO neurons only coded the cross-coupled pitch or roll components that move the axis of eye rotation toward the spatial vertical. Sixty-five percent of these VO and VPS neurons were more sensitive to rotation in one direction (predominantly contralateral), providing directional orientation for the subset of VO neurons on either side of the brainstem. This indicates that the three-dimensional velocity storage integrator is composed of directional subsets of neurons that are likely to be the bases for the spatial characteristics of velocity storage. Most VPS neurons ceased firing during drowsiness, but the firing rates of VO neurons were unaffected by states of alertness and declined with the time constant of velocity storage. Thus, the VO neurons are the prime components of the mechanism of coding for velocity storage, whereas the VPS neurons are likely to provide the path from the vestibular to the oculomotor system for the VO neurons.

  11. Coding of Velocity Storage in the Vestibular Nuclei

    PubMed Central

    Yakushin, Sergei B.; Raphan, Theodore; Cohen, Bernard

    2017-01-01

    Semicircular canal afferents sense angular acceleration and output angular velocity with a short time constant of ≈4.5 s. This output is prolonged by a central integrative network, velocity storage that lengthens the time constants of eye velocity. This mechanism utilizes canal, otolith, and visual (optokinetic) information to align the axis of eye velocity toward the spatial vertical when head orientation is off-vertical axis. Previous studies indicated that vestibular-only (VO) and vestibular-pause-saccade (VPS) neurons located in the medial and superior vestibular nucleus could code all aspects of velocity storage. A recently developed technique enabled prolonged recording while animals were rotated and received optokinetic stimulation about a spatial vertical axis while upright, side-down, prone, and supine. Firing rates of 33 VO and 8 VPS neurons were studied in alert cynomolgus monkeys. Majority VO neurons were closely correlated with the horizontal component of velocity storage in head coordinates, regardless of head orientation in space. Approximately, half of all tested neurons (46%) code horizontal component of velocity in head coordinates, while the other half (54%) changed their firing rates as the head was oriented relative to the spatial vertical, coding the horizontal component of eye velocity in spatial coordinates. Some VO neurons only coded the cross-coupled pitch or roll components that move the axis of eye rotation toward the spatial vertical. Sixty-five percent of these VO and VPS neurons were more sensitive to rotation in one direction (predominantly contralateral), providing directional orientation for the subset of VO neurons on either side of the brainstem. This indicates that the three-dimensional velocity storage integrator is composed of directional subsets of neurons that are likely to be the bases for the spatial characteristics of velocity storage. Most VPS neurons ceased firing during drowsiness, but the firing rates of VO neurons were unaffected by states of alertness and declined with the time constant of velocity storage. Thus, the VO neurons are the prime components of the mechanism of coding for velocity storage, whereas the VPS neurons are likely to provide the path from the vestibular to the oculomotor system for the VO neurons. PMID:28861030

  12. Facile fabrication of novel BiVO4/Bi2S3/MoS2 n-p heterojunction with enhanced photocatalytic activities towards pollutant degradation under natural sunlight.

    PubMed

    Wang, Jingzhen; Jin, Jia; Wang, Xiangguo; Yang, Shengnan; Zhao, Yinlan; Wu, Yawen; Dong, Shuying; Sun, Jingyu; Sun, Jianhui

    2017-11-01

    The novel three-component BiVO 4 /Bi 2 S 3 /MoS 2 heterojunction was successfully fabricated through a facile in-situ hydrothermal method based on the formation of the intermediate Bi 2 S 3 by coupling BiVO 4 and MoS 2 precursor. The Bi 2 S 3 was easily formed attributing to the strong interaction between Bi 3+ and S 2- ions with the aid of the hydrothermal reaction. The photocatalytic performances of samples were systematically investigated via the photocatalytic degradation of Rhodamine B (RhB), methylene blue (MB) and malachite green (MG) under solar light irradiation. As a result, the photocatalytic degradation rate of BM-10 for RhB, MB and MG are 97%, 93% and 94%, respectively. The enhanced photocatalytic activities could be due to the suppression of charge recombination and the enhanced the visible light absorption of BiVO 4 /Bi 2 S 3 /MoS 2 heterojunction. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Pulmonary O2 uptake on-kinetics in endurance- and sprint-trained master athletes.

    PubMed

    Berger, N J A; Rittweger, J; Kwiet, A; Michaelis, I; Williams, A G; Tolfrey, K; Jones, A M

    2006-12-01

    The purpose of this study was to characterise the VO2 kinetic response to moderate intensity cycle exercise in endurance-trained (END) and sprint or power-trained (SPR) track and field master athletes ranging in age from 45 to 85 years. We hypothesised that the time constant (tau) describing the Phase II VO2 on-response would be smaller in the END compared to the SPR athletes, and that the tau would become greater with increasing age in both groups. Eighty-four master athletes who were competing at either the British or European Veteran Athletics Championships acted as subjects, and were classified as either END (800 m - marathon; n = 41), or SPR (100 - 400 m and field events; n = 43) specialists. Subjects completed two 6 minute "step" transitions to a work rate of moderate intensity on a cycle ergometer and pulmonary gas exchange was measured breath-by-breath. Analysis of variance revealed that SPR athletes had slower VO2 on-kinetics (i.e., greater tau) compared to END athletes at each of the age groups studied: 46 - 55 yrs (END: 25 +/- 6 vs. SPR: 36 +/- 9 s; p < 0.10), 56 - 65 yrs (END: 25 +/- 5 vs. SPR: 35 +/- 10 s; p < 0.05), 66 - 75 yrs (END: 29 +/- 10 vs. SPR: 40 +/- 13 s; p < 0.05), and 76 - 85 yrs (END: 31 +/- 10 vs. SPR: 51 +/- 18 s; p < 0.05). The VO2 on-kinetics became slower with advancing age in the SPR athletes (p < 0.05 between 56 - 65 and 76 - 85 yrs) but were not significantly changed in the END athletes. The slower VO2 on-kinetics in SPR compared to END master athletes is consistent both with differences in physiology (e.g., muscle fibre type, oxidative/glycolytic capacity) and training between these specialist athletes. Master END athletes have similar tau values to their younger counterparts (approximately 25 s) suggesting that participation in endurance exercise training limits the slowing of VO2 on-kinetics with age in this population.

  14. Skeletal Muscle Mitochondrial Energetics Are Associated With Maximal Aerobic Capacity and Walking Speed in Older Adults

    PubMed Central

    2013-01-01

    Background. Lower ambulatory performance with aging may be related to a reduced oxidative capacity within skeletal muscle. This study examined the associations between skeletal muscle mitochondrial capacity and efficiency with walking performance in a group of older adults. Methods. Thirty-seven older adults (mean age 78 years; 21 men and 16 women) completed an aerobic capacity (VO2 peak) test and measurement of preferred walking speed over 400 m. Maximal coupled (State 3; St3) mitochondrial respiration was determined by high-resolution respirometry in saponin-permeabilized myofibers obtained from percutanous biopsies of vastus lateralis (n = 22). Maximal phosphorylation capacity (ATPmax) of vastus lateralis was determined in vivo by 31P magnetic resonance spectroscopy (n = 30). Quadriceps contractile volume was determined by magnetic resonance imaging. Mitochondrial efficiency (max ATP production/max O2 consumption) was characterized using ATPmax per St3 respiration (ATPmax/St3). Results. In vitro St3 respiration was significantly correlated with in vivo ATPmax (r 2 = .47, p = .004). Total oxidative capacity of the quadriceps (St3*quadriceps contractile volume) was a determinant of VO2 peak (r 2 = .33, p = .006). ATPmax (r 2 = .158, p = .03) and VO2 peak (r 2 = .475, p < .0001) were correlated with preferred walking speed. Inclusion of both ATPmax/St3 and VO2 peak in a multiple linear regression model improved the prediction of preferred walking speed (r 2 = .647, p < .0001), suggesting that mitochondrial efficiency is an important determinant for preferred walking speed. Conclusions. Lower mitochondrial capacity and efficiency were both associated with slower walking speed within a group of older participants with a wide range of function. In addition to aerobic capacity, lower mitochondrial capacity and efficiency likely play roles in slowing gait speed with age. PMID:23051977

  15. Skeletal muscle mitochondrial energetics are associated with maximal aerobic capacity and walking speed in older adults.

    PubMed

    Coen, Paul M; Jubrias, Sharon A; Distefano, Giovanna; Amati, Francesca; Mackey, Dawn C; Glynn, Nancy W; Manini, Todd M; Wohlgemuth, Stephanie E; Leeuwenburgh, Christiaan; Cummings, Steven R; Newman, Anne B; Ferrucci, Luigi; Toledo, Frederico G S; Shankland, Eric; Conley, Kevin E; Goodpaster, Bret H

    2013-04-01

    Lower ambulatory performance with aging may be related to a reduced oxidative capacity within skeletal muscle. This study examined the associations between skeletal muscle mitochondrial capacity and efficiency with walking performance in a group of older adults. Thirty-seven older adults (mean age 78 years; 21 men and 16 women) completed an aerobic capacity (VO2 peak) test and measurement of preferred walking speed over 400 m. Maximal coupled (State 3; St3) mitochondrial respiration was determined by high-resolution respirometry in saponin-permeabilized myofibers obtained from percutanous biopsies of vastus lateralis (n = 22). Maximal phosphorylation capacity (ATPmax) of vastus lateralis was determined in vivo by (31)P magnetic resonance spectroscopy (n = 30). Quadriceps contractile volume was determined by magnetic resonance imaging. Mitochondrial efficiency (max ATP production/max O2 consumption) was characterized using ATPmax per St3 respiration (ATPmax/St3). In vitro St3 respiration was significantly correlated with in vivo ATPmax (r (2) = .47, p = .004). Total oxidative capacity of the quadriceps (St3*quadriceps contractile volume) was a determinant of VO2 peak (r (2) = .33, p = .006). ATPmax (r (2) = .158, p = .03) and VO2 peak (r (2) = .475, p < .0001) were correlated with preferred walking speed. Inclusion of both ATPmax/St3 and VO2 peak in a multiple linear regression model improved the prediction of preferred walking speed (r (2) = .647, p < .0001), suggesting that mitochondrial efficiency is an important determinant for preferred walking speed. Lower mitochondrial capacity and efficiency were both associated with slower walking speed within a group of older participants with a wide range of function. In addition to aerobic capacity, lower mitochondrial capacity and efficiency likely play roles in slowing gait speed with age.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ivanov, Alexander S.; Bryantsev, Vyacheslav S.

    Uranium is used as the basic fuel for nuclear power plants, which generate significant amounts of electricity and have life cycle carbon emissions that are as low as renewable energy sources. However, the extraction of this valuable energy commodity from the ground remains controversial, mainly because of environmental and health impacts. Alternatively, seawater offers an enormous uranium resource that may be tapped at minimal environmental cost. Nowadays, amidoxime polymers are the most widely utilized sorbent materials for large-scale extraction of uranium from seawater, but they are not perfectly selective for uranyl, UO 2 2+. In particular, the competition between UOmore » 2 2+ and VO 2+/VO2+ cations poses a significant challenge to the effi-cient mining of UO 2 2+. Thus, screening and rational design of more selective ligands must be accomplished. One of the key components in achieving this goal is the establishment of computational techniques capable of assessing ligand selec-tivity trends. Here, we report an approach based on quantum chemical calculations that achieves high accuracy in repro-ducing experimental aqueous stability constants for VO 2+/VO 2+ complexes with ten different oxygen donor lig-ands. The predictive power of the developed computational protocol was demonstrated for amidoxime-type ligands, providing greater insights into new design strategies for the development of the next generation of adsorbents with high selectivity toward UO 2 2+over VO 2+/VO 2+ ions. Furthermore, the results of calculations suggest that alkylation of amidox-ime moieties present in poly(acrylamidoxime) sorbents can be a potential route to better discrimination between the uranyl and competing vanadium ions within seawater.« less

  17. Cardiovascular fitness and executive control during task-switching: an ERP study.

    PubMed

    Scisco, Jenna L; Leynes, P Andrew; Kang, Jie

    2008-07-01

    Cardiovascular fitness recently has been linked to executive control function in older adults. The present study examined the relationship between cardiovascular fitness and executive control in young adults using event-related potentials (ERPs). Participants completed a two-part experiment. In part one, a graded exercise test (GXT) was administered using a cycle ergometer to obtain VO(2)max, a measure of maximal oxygen uptake. High-fit participants had VO(2)max measures at or above the 70th percentile based on age and sex, and low-fit participants had VO(2)max measures at or below the 30th percentile. In part two, a task-switching paradigm was used to investigate executive control. Task-switching trials produced slower response times and greater amplitude for both the P3a and P3b components of the ERP relative to a non-switch trial block. No ERP components varied as a function of fitness group. These findings, combined with results from previous research, suggest that the relationship between greater cardiovascular fitness and better cognitive function emerges after early adulthood.

  18. Validation of Cut-Points for Evaluating the Intensity of Physical Activity with Accelerometry-Based Mean Amplitude Deviation (MAD).

    PubMed

    Vähä-Ypyä, Henri; Vasankari, Tommi; Husu, Pauliina; Mänttäri, Ari; Vuorimaa, Timo; Suni, Jaana; Sievänen, Harri

    2015-01-01

    Our recent study of three accelerometer brands in various ambulatory activities showed that the mean amplitude deviation (MAD) of the resultant acceleration signal performed best in separating different intensity levels and provided excellent agreement between the three devices. The objective of this study was to derive a regression model that estimates oxygen consumption (VO2) from MAD values and validate the MAD-based cut-points for light, moderate and vigorous locomotion against VO2 within a wide range of speeds. 29 participants performed a pace-conducted non-stop test on a 200 m long indoor track. The initial speed was 0.6 m/s and it was increased by 0.4 m/s every 2.5 minutes until volitional exhaustion. The participants could freely decide whether they preferred to walk or run. During the test they carried a hip-mounted tri-axial accelerometer and mobile metabolic analyzer. The MAD was calculated from the raw acceleration data and compared to directly measured incident VO2. Cut-point between light and moderate activity was set to 3.0 metabolic equivalent (MET, 1 MET = 3.5 ml · kg-1 · min-1) and between moderate and vigorous activity to 6.0 MET as per standard use. The MAD and VO2 showed a very strong association. Within individuals, the range of r values was from 0.927 to 0.991 providing the mean r = 0.969. The optimal MAD cut-point for 3.0 MET was 91 mg (milligravity) and 414 mg for 6.0 MET. The present study showed that the MAD is a valid method in terms of the VO2 within a wide range of ambulatory activities from slow walking to fast running. Being a device-independent trait, the MAD facilitates directly comparable, accurate results on the intensity of physical activity with all accelerometers providing tri-axial raw data.

  19. Usefulness of peak exercise oxygen consumption and the heart failure survival score to predict survival in patients >65 years of age with heart failure.

    PubMed

    Parikh, Mona N; Lund, Lars H; Goda, Ayumi; Mancini, Donna

    2009-04-01

    Peak exercise oxygen consumption (Vo(2)) and the Heart Failure (HF) Survival Score (HFSS) were developed in middle-aged patient cohorts referred for heart transplantation with HF. The prognostic value of Vo(2) in patients >65 years has not been well studied. Accordingly, the prognostic value of peak Vo(2) was evaluated in these patients with HF. A retrospective analysis of 396 patients with HF >65 years with cardiopulmonary exercise testing was performed. Peak Vo(2) and components of the HFSS (presence of coronary artery disease, left ventricular ejection fraction, heart rate, mean arterial blood pressure, presence of intraventricular conduction defects, and serum sodium) were collected. Follow-up averaged 1,038 +/- 983 days. Outcome events were defined as death, implantation of a left ventricular assist device, or urgent transplantation. Patients were divided into risk strata for peak Vo(2) and HFSS based on previous cut-off points. Survival curves were derived using Kaplan-Meier analysis and compared using log-rank analysis. Survival differed markedly by Vo(2) stratum (p <0.0001), with significantly better survival rates for the low- (>14 ml/kg/min) versus medium- (10 to 14 ml/kg/min), low- versus high- (<10 ml/kg/min), and medium- versus high-risk strata (all p <0.05). Survival also differed markedly by HFSS stratum (p <0.0001), with significantly better survival rates for the low- (> or =8.10) versus medium- (7.20 to 8.09), low- versus high- (< or =7.19), and medium- versus high-risk strata (all p <0.0001). In conclusion, peak Vo(2) and the HFSS were both excellent parameters to predict survival in patients >65 years with HF.

  20. VO2 kinetics determined by PRBS techniques differentiate elite endurance runners from elite sprinters.

    PubMed

    Edwards, A M; Challis, N V; Chapman, J H; Claxton, D B; Fysh, M L

    1999-01-01

    The aim of the study was to examine whether a measure of oxygen uptake (VO2) kinetics could differentiate between 12 elite male endurance (3000-10,000 m) runners and 12 elite male sprint (100-400 m) runners using a pseudo random binary sequence (PRBS) exercise protocol. All exercise tests were performed on an electrically braked cycle ergometer at a constant pedal frequency of 1 Hz. The PRBS exercise intensities alternated between 25 W and 85 W for three consecutive PRBS cycles of 300 s. VO2 was measured breath-by-breath and results were analysed by Fourier techniques in the frequency domain. Blood lactate concentrations taken pre and post testing were below 2 mM. Significantly greater amplitude components were observed in the endurance runners than sprinters at frequencies 6.7 mHz (6.71 +/- 1.09 and 5.47 +/- 0.95 ml x min(-1) x W(-1), respectively) P<0.05 and 10 mHz (4.97 +/- 0.98 and 3.56 +/- 0.69 ml x min(-1) x W(-1) respectively) P<0.01. Phase shift components were significantly shorter in the endurance runners compared to the sprinters at frequency 3.3 mHz (-35.45 +/- 4.31 and -41.26 +/- 5.82 degrees respectively) P<0.05. The results of this study show that VO2 kinetics are differentially faster in elite endurance runners than in elite sprinters. This supports the development of the PRBS technique as a test of sports performance.

  1. Study of the relationship between the aerobic capacity (VO2 max) and the rating of perceived exertion based on the measurement of heart beat in the metal industries Esfahan

    PubMed Central

    Habibi, Ehsanollah; Dehghan, Habibollah; Moghiseh, Mohammad; Hasanzadeh, Akbar

    2014-01-01

    Background and Objective: To establish a balance between work (physical exercise) and human beings, the aerobic capacity (VO2 max) could be used as a measure. Additionally, the subjective and physiological assessment could be applied as one of the methods for assessing physical exercise. The most commonly used tools for the assessment of fatigue during physical exercise include the Borg scale Rating of perceived Exertion (RPE) in relation to subjective symptoms and heart rate (HR) in relation to physiological symptoms. The study is aimed to investigate the relationship between the aerobic capacity and the RPE based on the measurement of heat rate (HR) of workers from the Metal Industries of Isfahan. Materials and Methods: The subjects were 200 male workers from metal components manufacturers in Isfahan selected by using random sampling based on statistic method. The subjects were examined by using ergometer in accordance with A strand 6 minutes cycle test protocol. Furthermore, the subjects were asked to rate their status based on the Borg rating scale at the end of each minute. Additionally, their heat rates were monitored and recorded automatically at the end of each minutes. Results: Statistical analysis showed that there was a significant relationship between the RPE and the aerobic capacity (VO2 max) (r = –0.904, P < 0.05). The results illustrated that there was a stronger correlation between HR and VO2 max (r = 0.991, P < 0.001). The regression analysis of the quadratic equation also indicated that there was also a significant relationship between the VO2 max and HR. Conclusions: The results indicated that there was a strong relationship between the RPE and VO2 max, as well as a greater correlation between HR and VO2 max. Therefore, the HR could be used as a Prediction measure to estimate VO2 max. PMID:25077148

  2. Investigation of a Structural Phase Transition and Magnetic Structure of Na 2BaFe(VO 4) 2: A Triangular Magnetic Lattice with a Ferromagnetic Ground State

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanjeewa, Liurukara D.; Garlea, Vasile O.; McGuire, Michael A.

    The structural and magnetic properties of a glaserite-type Na 2BaFe(VO 4) 2 compound, featuring a triangular magnetic lattice of Fe 2+ (S = 2), are reported. Temperature dependent X-ray single crystal studies indicate that at room temperature the system adopts a trigonal Pmore » $$\\bar{3}$$ m1 structure and undergoes a structural phase transition to a C2/c monoclinic phase slightly below room temperature (T s = 288 K). This structural transition involves a tilting of Fe–O–V bond angles and strongly influences the magnetic correlation within the Fe triangular lattice. The magnetic susceptibility measurements reveal a ferromagnetic transition near 7 K. Single crystal neutron diffraction confirms the structural distortion and the ferromagnetic spin ordering in Na 2BaFe(VO 4) 2. The magnetic structure of the ordered state is modeled in the magnetic space group C2'/c' that implies a ferromagnetic order of the a and c moment components and antiferromagnetic arrangement for the b components. Altogether, the Fe magnetic moments form ferromagnetic layers that are stacked along the c-axis, where the spins point along one of the (111) facets of the FeO 6 octahedron.« less

  3. Investigation of a Structural Phase Transition and Magnetic Structure of Na 2BaFe(VO 4) 2: A Triangular Magnetic Lattice with a Ferromagnetic Ground State

    DOE PAGES

    Sanjeewa, Liurukara D.; Garlea, Vasile O.; McGuire, Michael A.; ...

    2017-12-07

    The structural and magnetic properties of a glaserite-type Na 2BaFe(VO 4) 2 compound, featuring a triangular magnetic lattice of Fe 2+ (S = 2), are reported. Temperature dependent X-ray single crystal studies indicate that at room temperature the system adopts a trigonal Pmore » $$\\bar{3}$$ m1 structure and undergoes a structural phase transition to a C2/c monoclinic phase slightly below room temperature (T s = 288 K). This structural transition involves a tilting of Fe–O–V bond angles and strongly influences the magnetic correlation within the Fe triangular lattice. The magnetic susceptibility measurements reveal a ferromagnetic transition near 7 K. Single crystal neutron diffraction confirms the structural distortion and the ferromagnetic spin ordering in Na 2BaFe(VO 4) 2. The magnetic structure of the ordered state is modeled in the magnetic space group C2'/c' that implies a ferromagnetic order of the a and c moment components and antiferromagnetic arrangement for the b components. Altogether, the Fe magnetic moments form ferromagnetic layers that are stacked along the c-axis, where the spins point along one of the (111) facets of the FeO 6 octahedron.« less

  4. Assessing ligand selectivity for uranium over vanadium ions to aid in the discovery of superior adsorbents for extraction of UO 2 2+ from seawater

    DOE PAGES

    Ivanov, Alexander S.; Bryantsev, Vyacheslav S.

    2016-06-06

    Uranium is used as the basic fuel for nuclear power plants, which generate significant amounts of electricity and have life cycle carbon emissions that are as low as renewable energy sources. However, the extraction of this valuable energy commodity from the ground remains controversial, mainly because of environmental and health impacts. Alternatively, seawater offers an enormous uranium resource that may be tapped at minimal environmental cost. Nowadays, amidoxime polymers are the most widely utilized sorbent materials for large-scale extraction of uranium from seawater, but they are not perfectly selective for uranyl, UO 2 2+. In particular, the competition between UOmore » 2 2+ and VO 2+/VO2+ cations poses a significant challenge to the effi-cient mining of UO 2 2+. Thus, screening and rational design of more selective ligands must be accomplished. One of the key components in achieving this goal is the establishment of computational techniques capable of assessing ligand selec-tivity trends. Here, we report an approach based on quantum chemical calculations that achieves high accuracy in repro-ducing experimental aqueous stability constants for VO 2+/VO 2+ complexes with ten different oxygen donor lig-ands. The predictive power of the developed computational protocol was demonstrated for amidoxime-type ligands, providing greater insights into new design strategies for the development of the next generation of adsorbents with high selectivity toward UO 2 2+over VO 2+/VO 2+ ions. Furthermore, the results of calculations suggest that alkylation of amidox-ime moieties present in poly(acrylamidoxime) sorbents can be a potential route to better discrimination between the uranyl and competing vanadium ions within seawater.« less

  5. The Positive Effects of Priming Exercise on Oxygen Uptake Kinetics and High-Intensity Exercise Performance Are Not Magnified by a Fast-Start Pacing Strategy in Trained Cyclists

    PubMed Central

    Caritá, Renato Aparecido Corrêa; Greco, Camila Coelho; Denadai, Benedito Sérgio

    2014-01-01

    The purpose of this study was to determine both the independent and additive effects of prior heavy-intensity exercise and pacing strategies on the VO2 kinetics and performance during high-intensity exercise. Fourteen endurance cyclists (VO2max  = 62.8±8.5 mL.kg−1.min−1) volunteered to participate in the present study with the following protocols: 1) incremental test to determine lactate threshold and VO2max; 2) four maximal constant-load tests to estimate critical power; 3) six bouts of exercise, using a fast-start (FS), even-start (ES) or slow-start (SS) pacing strategy, with and without a preceding heavy-intensity exercise session (i.e., 90% critical power). In all conditions, the subjects completed an all-out sprint during the final 60 s of the test as a measure of the performance. For the control condition, the mean response time was significantly shorter (p<0.001) for FS (27±4 s) than for ES (32±5 s) and SS (32±6 s). After the prior exercise, the mean response time was not significantly different among the paced conditions (FS = 24±5 s; ES = 25±5 s; SS = 26±5 s). The end-sprint performance (i.e., mean power output) was only improved (∼3.2%, p<0.01) by prior exercise. Thus, in trained endurance cyclists, an FS pacing strategy does not magnify the positive effects of priming exercise on the overall VO2 kinetics and short-term high-intensity performance. PMID:24740278

  6. Functional properties of slow and fast gastrocnemius muscle fibers after a 17-day spaceflight

    NASA Technical Reports Server (NTRS)

    Widrick, J. J.; Romatowski, J. G.; Norenberg, K. M.; Knuth, S. T.; Bain, J. L.; Riley, D. A.; Trappe, S. W.; Trappe, T. A.; Costill, D. L.; Fitts, R. H.

    2001-01-01

    The purpose of this investigation was to study the effects of a 17-day spaceflight on the contractile properties of individual fast- and slow-twitch fibers isolated from biopsies of the fast-twitch gastrocnemius muscle of four male astronauts. Single chemically skinned fibers were studied during maximal Ca2+-activated contractions with fiber myosin heavy chain (MHC) isoform expression subsequently determined by SDS gel electrophoresis. Spaceflight had no significant effect on the mean diameter or specific force of single fibers expressing type I, IIa, or IIa/IIx MHC, although a small reduction in average absolute force (P(o)) was observed for the type I fibers (0.68 +/- 0.02 vs. 0.64 +/- 0.02 mN, P < 0.05). Subject-by-flight interactions indicated significant intersubject variation in response to the flight, as postflight fiber diameter and P(o) where significantly reduced for the type I and IIa fibers obtained from one astronaut and for the type IIa fibers from another astronaut. Average unloaded shortening velocity [V(o), in fiber lengths (FL)/s] was greater after the flight for both type I (0.60 +/- 0.03 vs. 0.76 +/- 0.02 FL/s) and IIa fibers (2.33 +/- 0.25 vs. 3.10 +/- 0.16 FL/s). Postflight peak power of the type I and IIa fibers was significantly reduced only for the astronaut experiencing the greatest fiber atrophy and loss of P(o). These results demonstrate that 1) slow and fast gastrocnemius fibers show little atrophy and loss of P(o) but increased V(o) after a typical 17-day spaceflight, 2) there is, however, considerable intersubject variation in these responses, possibly due to intersubject differences in in-flight physical activity, and 3) in these four astronauts, fiber atrophy and reductions in P(o) were less for slow and fast fibers obtained from the phasic fast-twitch gastrocnemius muscle compared with slow and fast fibers obtained from the slow antigravity soleus [J. J. Widrick, S. K. Knuth, K. M. Norenberg, J. G. Romatowski, J. L. W. Bain, D. A. Riley, M. Karhanek, S. W. Trappe, T. A. Trappe, D. L. Costill, and R. H. Fitts. J Physiol (Lond) 516: 915-930, 1999].

  7. The application of soccer performance testing protocols to the non-elite player.

    PubMed

    Siegler, J; Robergs, R; Weingart, H

    2006-03-01

    The application of performance testing for the evaluation of non-elite soccer players has received little attention. The purpose of this investigation was to use tests developed for elite soccer players to evaluate performance in non-elite soccer players and compare performance test results between elite (literature) and non-elite (data) players. Thirteen male soccer players volunteered to participate. The tests included a treadmill VO2max test, 20 m sprint, vertical jump (VJ), 30 s Wingate cycle ergometer test, the Loughborough Intermittent Shuttle Test (LIST), and 2 20-m multi-stage shuttle runs to exhaustion (fatigue test). Actual VO2max (absolute and relative) scores were correlated with the estimated VO2max scores (fatigue test), 20 m sprint, VJ, and 30 s Wingate using a Pearson's product-moment correlation. A paired t-test was conducted on the fatigue test trials. Non-significant relationships were observed between actual VO2max scores and estimated VO2max from the fatigue test (absolute and relative terms). Non-significant relationships were also observed between peak and average power output (Wingate), 20 m sprint, and VJ. Mean heart rates (HRs) throughout the LIST was 165+/-7 bpm, which represented 88% of HRmax. The results of this study demonstrate that to elicit physiological differences between elite and non-elite players, assessment must include both an aerobic and anaerobic component.

  8. Sarcopenia Is Associated With Lower Skeletal Muscle Capillarization and Exercise Capacity in Older Adults.

    PubMed

    Prior, Steven J; Ryan, Alice S; Blumenthal, Jacob B; Watson, Jonathan M; Katzel, Leslie I; Goldberg, Andrew P

    2016-08-01

    Skeletal muscle capillary rarefaction limits the transcapillary transport of nutrients and oxygen to muscle and may contribute to sarcopenia and functional impairment in older adults. We tested the hypothesis that skeletal muscle capillarization and exercise capacity (VO2max) are lower in sarcopenic than in nonsarcopenic older adults and that the degree of sarcopenia is related to lower skeletal muscle capillarization. Body composition, VO2max, and vastus lateralis capillarization were determined in 76 middle-aged and older men and women (age = 61±1 years, body mass index [BMI] = 30.7±0.5kg/m(2) [mean ± SEM]). Participants were classified as sarcopenic if appendicular lean mass divided by BMI (ALMBMI) was less than 0.789 for men or less than 0.512 for women. Sarcopenic subjects (ALMBMI = 0.65±0.04, n = 16) had 20% lower capillary-to-fiber ratio, as well as 13% and 15% lower VO2max expressed as mL/kg/min or L/min, respectively, compared with sex-, race-, and age-matched participants without sarcopenia (ALMBMI = 0.81±0.05, n = 16; p < .05). In all 76 subjects, ALMBMI, thigh muscle cross-sectional area, and VO2max correlated directly with capillarization (r = .30-.37, p ≤ .05), after accounting for age, sex, and race. These findings suggest that low skeletal muscle capillarization is one factor that may contribute to sarcopenia and reduced exercise capacity in older adults by limiting diffusion of substrates, oxygen, hormones, and nutrients. Strategies to prevent the aging-related decline in skeletal muscle capillarization may help to prevent or slow the progression of sarcopenia and its associated functional declines in generally healthy older adults. Published by Oxford University Press on behalf of the Gerontological Society of America 2016.

  9. Validation and application of single breath cardiac output determinations in man

    NASA Technical Reports Server (NTRS)

    Loeppky, J. A.; Fletcher, E. R.; Myhre, L. G.; Luft, U. C.

    1986-01-01

    The results of a procedure for estimating cardiac output by a single-breath technique (Qsb), obtained in healthy males during supine rest and during exercise on a bicycle ergometer, were compared with the results on cardiac output obtained by the direct Fick method (QF). The single breath maneuver consisted of a slow exhalation to near residual volume following an inspiration somewhat deeper than normal. The Qsb calculations incorporated an equation of the CO2 dissociation curve and a 'moving spline' sequential curve-fitting technique to calculate the instantaneous R from points on the original expirogram. The resulting linear regression equation indicated a 24-percent underestimation of QF by the Qsb technique. After applying a correction, the Qsb-QF relationship was improved. A subsequent study during upright rest and exercise to 80 percent of VO2(max) in 6 subjects indicated a close linear relationship between Qsb and VO2 for all 95 values obtained, with slope and intercept close to those in published studies in which invasive cardiac output measurements were used.

  10. Economy and rate of carbohydrate oxidation during running with rearfoot and forefoot strike patterns.

    PubMed

    Gruber, Allison H; Umberger, Brian R; Braun, Barry; Hamill, Joseph

    2013-07-15

    It continues to be argued that a forefoot (FF) strike pattern during running is more economical than a rearfoot (RF) pattern; however, previous studies using one habitual footstrike group have found no difference in running economy between footstrike patterns. We aimed to conduct a more extensive study by including both habitual RF and FF runners. The purposes of this study were to determine whether there were differences in running economy between these groups and whether running economy would change when they ran with the alternative footstrike pattern. Nineteen habitual RF and 18 habitual FF runners performed the RF and FF patterns on a treadmill at 3.0, 3.5, and 4.0 m/s. Steady-state rates of oxygen consumption (Vo2, ml·kg(-1)·min(-1)) and carbohydrate contribution to total energy expenditure (%CHO) were determined by indirect calorimetry for each footstrike pattern and speed condition. A mixed-model ANOVA was used to assess the differences in each variable between groups and footstrike patterns (α = 0.05). No differences in Vo2 or %CHO were detected between groups when running with their habitual footstrike pattern. The RF pattern resulted in lower Vo2 and %CHO compared with the FF pattern at the slow and medium speeds in the RF group (P < 0.05) but not in the FF group (P > 0.05). At the fast speed, a significant footstrike pattern main effect indicated that Vo2 was greater with the FF pattern than with the RF pattern (P < 0.05), but %CHO was not different (P > 0.05). The results suggest that the FF pattern is not more economical than the RF pattern.

  11. Active Terahertz Chiral Metamaterials Based on Phase Transition of Vanadium Dioxide (VO2).

    PubMed

    Wang, Shengxiang; Kang, Lei; Werner, Douglas H

    2018-01-09

    Compared with natural materials, chiral metamaterials have been demonstrated with orders of magnitude stronger chiroptical response, which provides the basis for applications such as ultracompact polarization components and plasmonic-enhanced biosensing. Terahertz chiral metamaterials that allow dynamic polarization control of terahertz waves are of great practical interest, but remain extremely rare. Here, we show that hybrid metamaterials integrated with vanadium dioxide (VO 2 ) exhibiting phase transition can enable dynamically tunable chiroptical responses at terahertz frequencies. In particular, a circular dichroism of ~40° and a maximum polarization rotation of ~200°/λ are observed around 0.7 THz. Furthermore, our study also reveals that the chiroptical response from the proposed metamaterials is strongly dependent on the phase transition of VO 2 , leading to actively controllable polarization states of the transmitted terahertz waves. This work paves the way for the development of terahertz metadevices capable of enabling active polarization manipulation.

  12. Integrating a Semitransparent, Fullerene-Free Organic Solar Cell in Tandem with a BiVO4 Photoanode for Unassisted Solar Water Splitting.

    PubMed

    Peng, Yuelin; Govindaraju, Gokul V; Lee, Dong Ki; Choi, Kyoung-Shin; Andrew, Trisha L

    2017-07-12

    We report an unassisted solar water splitting system powered by a diketopyrrolopyrrole (DPP)-containing semitransparent organic solar cell. Two major merits of this fullerene-free solar cell enable its integration with a BiVO 4 photoanode. First is the high open circuit voltage and high fill factor displayed by this single junction solar cell, which yields sufficient power to effect water splitting when serially connected to an appropriate electrode/catalyst. Second, the wavelength-resolved photoaction spectrum of the DPP-based solar cell has minimal overlap with that of the BiVO 4 photoanode, thus ensuring that light collection across these two components can be optimized. The latter feature enables a new water splitting device configuration wherein the solar cell is placed first in the path of incident light, before the BiVO 4 photoanode, although BiVO 4 has a wider bandgap. This configuration is accessed by replacing the reflective top electrode of the standard DPP-based solar cell with a thin metal film and an antireflection layer, thus rendering the solar cell semitransparent. In this configuration, incident light does not travel through the aqueous electrolyte to reach the solar cell or photoanode, and therefore, photon losses due to the scattering of water are reduced. Moreover, this new configuration allows the BiVO 4 photoanode to be back-illuminated, i.e., through the BiVO 4 /back contact interface, which leads to higher photocurrents compared to front illumination. The combination of a semitransparent single-junction solar cell and a BiVO 4 photoanode coated with oxygen evolution catalysts in a new device configuration yielded an unassisted solar water splitting system with a solar-to-hydrogen conversion efficiency of 2.2% in water.

  13. Nondestructive evaluation of fatigue damage on low alloy steel by magnetomechanical acoustic emission technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hiraasawa, T.; Saito, K.; Komura, I.

    1995-08-01

    A modified magnetomechanical acoustic emission (MAE) technique, denoted Pulse-MAE, in which the magnetization by current pulse was adopted, was newly developed and its applicability was assessed for the nondestructive detection and evaluation of fatigue damage in reactor pressure vessel steel SFVV2 and SA508 class2. MAE signals were measured with both conventional MAE and Pulse-MAE technique for fatigue damaged specimens having several damage fractions, and peak voltage ratio Vp/Vo, where Vp and Vo were the peak voltage for damaged and undamaged specimen respectively, was chosen as a measure. Vp/Vo was found to increase monotonously at the early stage of fatigue processmore » and the rate of increase in Vp/Vo during the fatigue process was larger in Pulse-MAE than conventional MAE. Therefore, Pulse-MAE technique proved to have higher sensitivity for the detection of fatigue damage compared with the conventional MAE and to have the potential of a practical technique for nondestructive detection and evaluation of fatigue damage in actual components.« less

  14. Hyperventilation-induced hypocapnic alkalosis slows the adaptation of pulmonary O2 uptake during the transition to moderate-intensity exercise.

    PubMed

    Chin, Lisa M K; Leigh, Ryan J; Heigenhauser, George J F; Rossiter, Harry B; Paterson, Donald H; Kowalchuk, John M

    2007-08-15

    The effect of voluntary hyperventilation-induced hypocapnic alkalosis (RALK) on pulmonary O2 uptake (VO2) kinetics and muscle deoxygenation was examined in young male adults (n=8) during moderate-intensity exercise. Subjects performed five repetitions of a step-transition in work rate from 20 W cycling to a work rate corresponding to 90% of the estimated lactate threshold during control (CON; PET,CO2, approximately 40 mmHg) and during hyperventilation (RALK; PET,CO2, approximately 20 mmHg). was measured breath-by-breath and relative concentration changes in muscle deoxy- (DeltaHHb), oxy- (DeltaO2Hb) and total (DeltaHbtot) haemoglobin were measured continuously using near-infrared (NIR) spectroscopy (Hamamatsu, NIRO 300). The time constant for the fundamental, phase 2, VO2 response (tau VO2) was greater (P<0.05) in RALK (48+/-11 s) than CON (31+/-9 s), while tauHHb was similar between conditions (RALK, 12+/-4 s; CON, 11+/-4 s). The DeltaHb(tot) was lower (P<0.05) in RALK than CON, prior to (RALK, -3+/-5 micromol l(-1); CON, -1+/-4 micromol l(-1)) and at the end (RALK, 1+/-6 micromol l(-1); CON, 5+/-5 micromol l(-1)) of moderate-intensity exercise. Although slower adaptation of during RALK may be related to an attenuated activation of PDH (and other enzymes) and provision of oxidizable substrate to the mitochondria (i.e. metabolic inertia), the present findings also suggest a role for a reduction in local muscle perfusion and O2 delivery.

  15. Microvascular oxygen pressures in muscles comprised of different fiber types: Impact of dietary nitrate supplementation.

    PubMed

    Ferguson, Scott K; Holdsworth, Clark T; Wright, Jennifer L; Fees, Alex J; Allen, Jason D; Jones, Andrew M; Musch, Timothy I; Poole, David C

    2015-08-01

    Nitrate (NO3(-)) supplementation via beetroot juice (BR) preferentially improves vascular conductance and O2 delivery to contracting skeletal muscles comprised predominantly of type IIb + d/x (i.e. highly glycolytic) fibers following its reduction to nitrite and nitric oxide (NO). To address the mechanistic basis for NO3(-) to improve metabolic control we tested the hypothesis that BR supplementation would elevate microvascular PO2 (PO2mv) in fast twitch but not slow twitch muscle. Twelve young adult male Sprague-Dawley rats were administered BR ([NO3(-)] 1 mmol/kg/day, n = 6) or water (control, n = 6) for 5 days. PO2mv (phosphorescence quenching) was measured at rest and during 180 s of electrically-induced 1-Hz twitch contractions (6-8 V) of the soleus (9% type IIb +d/x) and mixed portion of the gastrocnemius (MG, 91% type IIb + d/x) muscles. In the MG, but not the soleus, BR elevated contracting steady state PO2mv by ~43% (control: 14 ± 1, BR: 19 ± 2 mmHg (P < 0.05)). This higher PO2mv represents a greater blood-myocyte O2 driving force during muscle contractions thus providing a potential mechanism by which NO3(-) supplementation via BR improves metabolic control in fast twitch muscle. Recruitment of higher order type II muscle fibers is thought to play a role in the development of the VO2 slow component which is inextricably linked to the fatigue process. These data therefore provide a putative mechanism for the BR-induced improvements in high-intensity exercise performance seen in humans. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Comparison between Slow Components of HR and V[Combining Dot Above]O2 Kinetics: Functional Significance.

    PubMed

    Zuccarelli, Lucrezia; Porcelli, Simone; Rasica, Letizia; Marzorati, Mauro; Grassi, Bruno

    2018-03-22

    Aerobic exercise prescription is often based on a linear relationship between pulmonary oxygen consumption (V[Combining Dot Above]O2) and heart rate (HR). The aim of the present study was to test the hypothesis that during constant work rate (CWR) exercises at different intensities the slow component of HR kinetics occurs at lower work rate and is more pronounced that the slow component of V[Combining Dot Above]O2 kinetics. Seventeen male (age, 27±4yr) subjects performed on a cycle ergometer an incremental exercise to voluntary exhaustion and several CWR exercises: 1) moderate CWR exercises (MODERATE), below gas exchange threshold (GET); 2) heavy CWR exercise (HEAVY), at 45% of the difference between GET and V[Combining Dot Above]O2 peak (□); 3) severe CWR exercise (SEVERE), at 95% of Δ; 4) "HRCLAMPED" exercise in which work rate was continuously adjusted to maintain a constant HR, slightly higher than that determined at GET. Breath-by-breath V[Combining Dot Above]O2, HR and other variables were determined. In MODERATE, no slow component of V[Combining Dot Above]O2 kinetics was observed, whereas a slow component with a relative amplitude (with respect to the total response) of 24.8±11.0% was observed for HR kinetics. During HEAVY, the relative amplitude of the HR slow component was more pronounced than that for V[Combining Dot Above]O2 (31.6±11.2 and 23.3±9.0%, respectively). During HRCLAMPED the decrease in work rate (~14%) needed in order to maintain a constant HR was associated with a decreased V[Combining Dot Above]O2 (~10%). The HR slow component occurred at a lower work rate and was more pronounced than the V[Combining Dot Above]O2 slow component. Exercise prescriptions at specific HR values, when carried out for periods longer than a few minutes, could lead to premature fatigue.

  17. Microvascular oxygen pressures in muscles comprised of different fiber types: Impact of dietary nitrate supplementation

    PubMed Central

    Ferguson, Scott K.; Holdsworth, Clark T.; Wright, Jennifer L.; Fees, Alex J.; Allen, Jason D.; Jones, Andrew M.; Musch, Timothy I.; Poole, David C.

    2014-01-01

    Nitrate (NO3−) supplementation via beetroot juice (BR) preferentially improves vascular conductance and O2 delivery to contracting skeletal muscles comprised predominantly of type IIb + d/x (i.e. highly glycolytic) fibers following its reduction to nitrite and nitric oxide (NO). To address the mechanistic basis for NO3− to improve metabolic control we tested the hypothesis that increased NO bioavailability via BR supplementation would elevate microvascular PO2 (PO2mv) in fast twitch but not slow twitch muscle. Twelve young adult male Sprague-Dawley rats were administered BR ([NO3−] 1 mmol/kg/day, n=6) or water (control, n=6) for 5 days. PO2mv (phosphorescence quenching) was measured at rest and during 180s of electrically induced 1-Hz twitch contractions (6–8 V) of the soleus (9% type IIb +d/x) and mixed portion of the gastrocnemius (MG, 91% type IIb + d/x) muscles. In the MG, but not the soleus, BR elevated contracting steady state PO2mv by ~43% (control: 13.7 ± 0.5, BR: 19 ± 1.6 mmHg, (P<0.05). This higher PO2mv represents a greater blood-myocyte O2 driving force during muscle contractions thus providing a potential mechanism by which NO3− supplementation via BR improves metabolic control in fast twitch muscle. Recruitment of higher order type II muscle fibers is thought to play a role in the development of the V.O2 slow component which is inextricably linked to the fatigue process. These data therefore provide a putative mechanism for the BR-induced improvements in high-intensity exercise performance seen in humans. PMID:25280991

  18. Cardiorespiratory fitness is positively associated with a healthy dietary pattern in New Zealand adolescents.

    PubMed

    Howe, Anna S; Skidmore, Paula M L; Parnell, Winsome R; Wong, Jyh Eiin; Lubransky, Alexandra C; Black, Katherine E

    2016-05-01

    To examine the association between cardiorespiratory fitness and dietary patterns in adolescents. Food choice was assessed using the validated New Zealand Adolescent FFQ. Principal components analysis was used to determine dietary patterns. Trained research assistants measured participants' height and body mass. Cardiorespiratory fitness was assessed in a subset of participants using the multistage 20 m shuttle run. The level and stage were recorded, and the corresponding VO2max was calculated. Differences in mean VO2max according to sex and BMI were assessed using t tests, while associations between cardiorespiratory fitness and dietary patterns were examined using linear regression analyses adjusted for age, sex, school attended, socio-economic deprivation and BMI. Secondary schools in Otago, New Zealand. Students (n 279) aged 14-18 years who completed an online lifestyle survey during a class period. Principal components analysis produced three dietary patterns: 'Treat Foods', 'Fruits and Vegetables' and 'Basic Foods'. The 279 participants who provided questionnaire data and completed cardiorespiratory fitness testing had a mean age of 15·7 (sd 0·9) years. Mean VO2max was 45·8 (sd 6·9) ml/kg per min. The 'Fruits and Vegetables' pattern was positively associated with VO2max in the total sample (β=0·04; 95%CI 0·02, 0·07), girls (β=0·06; 95% CI 0·03, 0·10) and boys (β=0·03; 95% CI 0·01, 0·05). These results indicate that increase in cardiorespiratory fitness was associated with a healthier dietary pattern, suggesting both should be targeted as part of a global lifestyle approach. Longitudinal studies are needed to confirm this association in relation to health outcomes in New Zealand adolescents.

  19. Adsorption and Photodesorption of CO from Charged Point Defects on TiO 2 (110)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mu, Rentao; Dahal, Arjun; Wang, Zhi-Tao

    Adsorption and photodesorption of weakly-bound carbon monoxide, CO, from reduced and hydroxylated rutile TiO2(110) (r- and h- TiO2(110)) at sub-monolayer coverages is studied with atomically-resolved scanning tunneling microscopy (STM) along with ensemble-averaged temperature-programmed desorption (TPD) and angle-resolved photon-stimulated desorption (PSD) at low temperatures ( 50 K). STM data weighted by the concentration of each kind of adsorption sites on r-TiO2(110) give an adsorption probability which is the highest for the bridging oxygen vacancies (VO) and very low for the Ti5c sites closest to VO. Occupancy of the remaining Ti5c sites with CO is significant, but smaller than for VO. Themore » probability distribution for the different adsorption sites corresponds to a very small difference in CO adsorption energies: < 0.02 eV. We also find that UV irradiation stimulates both diffusion and desorption of CO at low temperature. CO photodesorbs primarily from the vacancies with a bi-modal angular distribution. In addition to a major, normal to the surface component, there is a broader cosine component indicating scattering from the surface which likely also leads to photo-stimulated diffusion. Hydroxylation of VO’s does not significantly change the CO PSD yield and angular distribution, indicating that not atomic but rather electronic surface defects are involved in the site-specific PSD process. We suggest that photodesorption can be initiated by recombination of photo-generated holes with excess unpaired electrons localized near the surface point-defect (either VO or bridging hydroxyl), leading to the surface atoms rearrangement and ejection of the weakly-bound CO molecules.« less

  20. Influence of acute moderate hypoxia on time to exhaustion at vVO2max in unacclimatized runners.

    PubMed

    Billat, V L; Lepretre, P M; Heubert, R P; Koralsztein, J P; Gazeau, F P

    2003-01-01

    Eight unacclimatized long-distance runners performed, on a level treadmill, an incremental test to determine the maximal oxygen uptake (VO2max) and the minimal velocity eliciting VO2max (vVO2max) in normoxia (N) and acute moderate hypoxia (H) corresponding to an altitude of 2,400 m (PIO 2 of 109 mmHg). Afterwards, on separate days, they performed two all-out constant velocity runs at vO2 max in a random order (one in N and the other in H). The decrease in VO2max between N and H showed a great degree of variability amongst subjects as VO2max decreased by 8.9 +/- 4 ml x min(-1) x kg)(-1) in H vs. N conditions (-15.3 +/- 6.3 % with a range from -7.9 % to -23.8 %). This decrease in VO2max was proportional to the value of VO2max (VO2max vs. delta VO2max N-H, r = 0.75, p = 0.03). The time run at vVO2max was not affected by hypoxia (483 +/- 122 vs. 506 +/- 148 s, in N and H, respectively, p = 0.37). However, the greater the decrease in vVO2max during hypoxia, the greater the runners increased their time to exhaustion at vVO2max (vVO2max N-H vs. tlim @vVO2max N-H, r = -0.75, p = 0.03). In conclusion, this study showed that there was a positive association between the extent of decrease in vVO2max, and the increase in run time at vVO2max in hypoxia.

  1. Comparison of the 1.5 Mile Run Times at 7,200 Feet and Simulated 850 Feet in a Hyperoxic Room

    DTIC Science & Technology

    2012-03-01

    Maximal Oxygen Update ( VO2 max) Test ......................................... 7 Figure 3 - VO2 Max results for Male, Female and All Subjects. * p...0.001 between Male and Female VO2 ’s. ............................................................. 11 Figure 4 - VO2 Max vs Predicted VO2 Max at 850...and 7,200 Feet ................. 12 Figure 5 - Actual VO2 Max vs Predicted VO2 Max at ALT (7,200 Feet) ....... 13 Figure 6 - VO2 Max vs Predicted

  2. Formation kinetics and mechanism of metastable vacancy-dioxygen complex in neutron irradiated Czochralski silicon

    NASA Astrophysics Data System (ADS)

    Dong, Peng; Wang, Rong; Yu, Xuegong; Chen, Lin; Ma, Xiangyang; Yang, Deren

    2017-07-01

    We have quantitatively investigated the formation kinetics of metastable vacancy-dioxygen (VO2) complex in a structure of [VO + Oi], where a VO complex is trapped in a next-neighbor position to an interstitial oxygen atom (Oi). It is found that the VO annihilation is accompanied by the generation of metastable [VO + Oi] complex during annealing in the temperature range of 220-250 °C. The activation energy for [VO + Oi] generation appears at around 0.48 eV, which is much lower than the counterpart of stable VO2 complex. This indicates that the formation of [VO + Oi] complex originates from the reaction between VO and Oi. The ab initio calculations show that the formation energy of [VO + Oi] complex is larger than that of VO2 complex, which means that [VO + Oi] complex is thermodynamically unfavorable as compared to VO2 complex. However, the binding energy of [VO + Oi] complex is positive, indicating that [VO + Oi] complex is stable against decomposition of VO and Oi in silicon. It is believed that [VO + Oi] complex serves as the intermediate for VO to VO2 conversion.

  3. Vanadium dioxide thin films prepared on silicon by low temperature MBE growth and ex-situ annealing

    NASA Astrophysics Data System (ADS)

    Homm, Pia; van Bilzen, Bart; Menghini, Mariela; Locquet, Jean-Pierre; Ivanova, Todora; Sanchez, Luis; Sanchis, Pablo

    Vanadium dioxide (VO2) is a material that shows an insulator to metal transition (IMT) near room temperature. This property can be exploited for applications in field effect devices, electro-optical switches and nonlinear circuit components. We have prepared VO2 thin films on silicon wafers by combining a low temperature MBE growth with an ex-situ annealing at high temperature. We investigated the structural, electrical and optical characteristics of films with thicknesses ranging from 10 to 100 nm. We have also studied the influence of the substrate cleaning. The films grown with our method are polycrystalline with a preferred orientation in the (011) direction of the monoclinic phase. For the films produced on silicon with a native oxide, an IMT at around 75 °C is observed. The magnitude of the resistance change across the IMT decreases with thickness while the refractive index at room temperature corresponds with values reported in the literature for thin films. The successful growth of VO2 films on silicon with good electrical and optical properties is an important step towards the integration of VO2 in novel devices. The authors acknowledge financial support from the FWO project G052010N10 and EU-FP7 SITOGA project. PH acknowledges support from Becas Chile - CONICYT.

  4. A Role of Erythrocytes in Adenosine Monophosphate Initiation of Hypometabolism in Mammals*

    PubMed Central

    Daniels, Isadora Susan; Zhang, Jianfa; O'Brien, William G.; Tao, Zhenyin; Miki, Tomoko; Zhao, Zhaoyang; Blackburn, Michael R.; Lee, Cheng Chi

    2010-01-01

    Biochemical and mechanistic aspects into how various hypometabolic states are initiated in mammals are poorly understood. Here, we show how a state of hypometabolism is initiated by 5′-AMP uptake by erythrocytes. Wild type, ecto-5′-nucleotidase-deficient, and adenosine receptor-deficient mice undergo 5′-AMP-induced hypometabolism in a similar fashion. Injection of 5′-AMP leads to two distinct declining phases of oxygen consumption (VO2). The phase I response displays a rapid and steep decline in VO2 that is independent of body temperature (Tb) and ambient temperature (Ta). It is followed by a phase II decline that is linked to Tb and moderated by Ta. Altering the dosages of 5′-AMP from 0.25- to 2-fold does not change the phase I response. For mice, a Ta of 15 °C is effective for induction of DH with the appropriate dose of 5′-AMP. Erythrocyte uptake of 5′-AMP leads to utilization of ATP to synthesize ADP. This is accompanied by increased glucose but decreased lactate levels, suggesting that glycolysis has slowed. Reduction in glycolysis is known to stimulate erythrocytes to increase intracellular levels of 2,3-bisphosphoglycerate, a potent allosteric inhibitor of hemoglobin's affinity for oxygen. Our studies showed that both 2,3-bisphosphoglycerate and deoxyhemoglobin levels rose following 5′-AMP administration and is in parallel with the phase I decline in VO2. In summary, our investigations reveal that 5′-AMP mediated hypometabolism is probably triggered by reduced oxygen transport by erythrocytes initiated by uptake of 5′-AMP. PMID:20430891

  5. A role of erythrocytes in adenosine monophosphate initiation of hypometabolism in mammals.

    PubMed

    Daniels, Isadora Susan; Zhang, Jianfa; O'Brien, William G; Tao, Zhenyin; Miki, Tomoko; Zhao, Zhaoyang; Blackburn, Michael R; Lee, Cheng Chi

    2010-07-02

    Biochemical and mechanistic aspects into how various hypometabolic states are initiated in mammals are poorly understood. Here, we show how a state of hypometabolism is initiated by 5'-AMP uptake by erythrocytes. Wild type, ecto-5'-nucleotidase-deficient, and adenosine receptor-deficient mice undergo 5'-AMP-induced hypometabolism in a similar fashion. Injection of 5'-AMP leads to two distinct declining phases of oxygen consumption (VO(2)). The phase I response displays a rapid and steep decline in VO(2) that is independent of body temperature (T(b)) and ambient temperature (T(a)). It is followed by a phase II decline that is linked to T(b) and moderated by T(a). Altering the dosages of 5'-AMP from 0.25- to 2-fold does not change the phase I response. For mice, a T(a) of 15 degrees C is effective for induction of DH with the appropriate dose of 5'-AMP. Erythrocyte uptake of 5'-AMP leads to utilization of ATP to synthesize ADP. This is accompanied by increased glucose but decreased lactate levels, suggesting that glycolysis has slowed. Reduction in glycolysis is known to stimulate erythrocytes to increase intracellular levels of 2,3-bisphosphoglycerate, a potent allosteric inhibitor of hemoglobin's affinity for oxygen. Our studies showed that both 2,3-bisphosphoglycerate and deoxyhemoglobin levels rose following 5'-AMP administration and is in parallel with the phase I decline in VO(2). In summary, our investigations reveal that 5'-AMP mediated hypometabolism is probably triggered by reduced oxygen transport by erythrocytes initiated by uptake of 5'-AMP.

  6. Relation of oxygen uptake to work rate in prepubertal healthy children - reference for VO2/W-slope and effect on cardiorespiratory fitness assessment.

    PubMed

    Tompuri, Tuomo; Lintu, Niina; Laitinen, Tomi; Lakka, Timo A

    2017-08-09

    Exercise testing by cycle ergometer allows to observe the interaction between oxygen uptake (VO 2 ) and workload (W), and VO 2 /W-slope can be used as a diagnostic tool. Respectively, peak oxygen uptake (VO 2 PEAK ) can be estimated by maximal workload. We aim to determine reference for VO 2 /W-slope among prepubertal children and define agreement between estimated and measured VO 2 PEAK . A total of 38 prepubertal children (20 girls) performed a maximal cycle ergometer test with respiratory gas analysis. VO 2 /W-slopes were computed using linear regression. Agreement analysis by Bland and Altman for estimated and measured VO 2 PEAK was carried out including limits of agreement (LA). Determinants for VO 2 /W-slopes and estimation bias were defined. VO2/W-slope was in both girls and boys ≥9·4 and did not change with exercise level, but the oxygen cost of exercise was higher among physically more active children. Estimated VO 2 PEAK had 6·4% coefficient of variation, and LA varied from 13% underestimation to 13% overestimation. Bias had a trend towards underestimation along lean mass proportional VO 2 PEAK . The primary determinant for estimation bias was VO2/W-slope (β = -0·65; P<0·001). The reference values for VO 2 /W-slope among healthy prepubertal children were similar to those published for adults and among adolescents. Estimated and measured VO 2 PEAK should not be considered to be interchangeable because of the variation in the relationship between VO 2 and W. On other hand, variation in the relationship between VO 2 and W enables that VO 2 /W-slope can be used as a diagnostic tool. © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  7. Masticatory myosin unveiled: first determination of contractile parameters of muscle fibers from carnivore jaw muscles.

    PubMed

    Toniolo, Luana; Cancellara, Pasqua; Maccatrozzo, Lisa; Patruno, Marco; Mascarello, Francesco; Reggiani, Carlo

    2008-12-01

    Masticatory myosin heavy chain (M MyHC) is a myosin subunit isoform with expression restricted to muscles derived from the first branchial arch, such as jaw-closer muscles, with pronounced interspecies variability. Only sparse information is available on the contractile properties of muscle fibers expressing M MyHC (M fibers). In this study, we characterized M fibers isolated from the jaw-closer muscles (temporalis and masseter) of two species of domestic carnivores, the cat and the dog, compared with fibers expressing slow or fast (2A, 2X, and 2B) isoforms. In each fiber, during maximally calcium-activated contractions at 12 degrees C, we determined isometric-specific tension (P(o)), unloaded shortening velocity (v(o)) with the slack test protocol, and the rate constant of tension redevelopment (K(TR)) after a fast shortening-relengthening cycle. At the end of the mechanical experiment, we identified MyHC isoform composition of each fiber with gel electrophoresis. Electrophoretic migration rate of M MyHC was similar in both species. We found that in both species the kinetic parameters v(o) and K(TR) of M fibers were similar to those of 2A fibers, whereas P(o) values were significantly greater than in any other fiber types. The similarity between 2A and M fibers and the greater tension development of M fibers were confirmed also in mechanical experiments performed at 24 degrees C. Myosin concentration was determined in single fibers and found not different in M fibers compared with slow and fast fibers, suggesting that the higher tension developed by M fibers does not find an explanation in a greater number of force generators. The specific mechanical characteristics of M fibers might be attributed to a diversity in cross-bridge kinetics.

  8. Preparation, characterization, and stereochemistry of binuclear vanadyl(IV) monomethyl- and dimethyltartrate(4-) complexes and the crystal structure of tetrasodium (. mu. -(+)-dimethyltartrato(4-))-(. mu. -(-)-dimethyltartrato(4-))-bis(oxovanadate(IV)) dodecahydrate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hahs, S.K.; Ortega, R.B.; Tapscott, R.E.

    1982-02-01

    The syntheses and characterizations (by ESR, IR, and electronic spectroscopies) of the sodium salts of the DL and DD (or LL) binuclear complexes of vanadyl(IV) with dimethyltartrate(4-), dmt, and with monomethyltartrate(4-), mmt, are described. Na/sub 4/((VO)/sub 22/((+)-dmt)((-)-dmt)) exists in two crystal forms - a blue dodecahydrate and a pink hexahydrate. An x-ray diffraction study of the former shows that the V-V distance (3.429 (3) A) of the binuclear anion is decreased relative to that of the unsubstituted tartrate(4-), tart, complex, as predicted from earlier ESR studies, and that this decrease is due in part to a dropping of the vanadiummore » atom into the plane of the four coordinating equatorial oxygen atoms. A sixth oxygen atom is weakly coordinated (2.377 (3) A) trans to the vanadyl oxygen atom. A purple tetradecahydrate also obtained with racenic dmt contains a mixture of ((VO)/sub 2/ ((+)-dmt)/sub 2/)/sup 4 -/ and ((VO)/sub 2/((-)-dmt)/sub 2/)/sup 4 -/). The aqueous solution ligand-exchange reaction between the DD and LL complexes of this salt to give the more stable DL isomer is remarkably slow (several hours at room temperature). Stereoselective effects allow the production of mixed-ligand species containing two of the three ligands tart, dmt, and mmt, and potentiometric titrations indicate a decreasing stability of the DL isomer (relative to the DD and LL isomers) as methyl substitution increases.« less

  9. Physiological and anthropometric determinants of rhythmic gymnastics performance.

    PubMed

    Douda, Helen T; Toubekis, Argyris G; Avloniti, Alexandra A; Tokmakidis, Savvas P

    2008-03-01

    To identify the physiological and anthropometric predictors of rhythmic gymnastics performance, which was defined from the total ranking score of each athlete in a national competition. Thirty-four rhythmic gymnasts were divided into 2 groups, elite (n = 15) and nonelite (n = 19), and they underwent a battery of anthropometric, physical fitness, and physiological measurements. The principal-components analysis extracted 6 components: anthropometric, flexibility, explosive strength, aerobic capacity, body dimensions, and anaerobic metabolism. These were used in a simultaneous multiple-regression procedure to determine which best explain the variance in rhythmic gymnastics performance. Based on the principal-component analysis, the anthropometric component explained 45% of the total variance, flexibility 12.1%, explosive strength 9.2%, aerobic capacity 7.4%, body dimensions 6.8%, and anaerobic metabolism 4.6%. Components of anthropometric (r = .50) and aerobic capacity (r = .49) were significantly correlated with performance (P < .01). When the multiple-regression model-y = 10.708 + (0.0005121 x VO2max) + (0.157 x arm span) + (0.814 x midthigh circumference) - (0.293 x body mass)-was applied to elite gymnasts, 92.5% of the variation was explained by VO2max (58.9%), arm span (12%), midthigh circumference (13.1%), and body mass (8.5%). Selected anthropometric characteristics, aerobic power, flexibility, and explosive strength are important determinants of successful performance. These findings might have practical implications for both training and talent identification in rhythmic gymnastics.

  10. Aqueous citrato-oxovanadate(IV) precursor solutions for VO2: synthesis, spectroscopic investigation and thermal analysis.

    PubMed

    Peys, Nick; Adriaensens, Peter; Van Doorslaer, Sabine; Gielis, Sven; Peeters, Ellen; De Dobbelaere, Christopher; De Gendt, Stefan; Hardy, An; Van Bael, Marlies K

    2014-09-07

    An aqueous precursor solution, containing citrato-VO(2+) complexes, is synthesized for the formation of monoclinic VO2. With regard to the decomposition of the VO(2+) complexes towards vanadium oxide formation, it is important to gain insights into the chemical structure and transformations of the precursor during synthesis and thermal treatment. Hence, the conversion of the cyclic [V4O12](4-) ion to the VO(2+) ion in aqueous solution, using oxalic acid as an acidifier and a reducing agent, is studied by (51)Vanadium nuclear magnetic resonance spectroscopy. The citrate complexation of this VO(2+) ion and the differentiation between a solution containing citrato-oxalato-VO(2+) and citrato-VO(2+) complexes are studied by electron paramagnetic resonance and Fourier transform infra-red spectroscopy. In both solutions, the VO(2+) containing complex is mononuclear and has a distorted octahedral geometry with a fourfold R-CO2(-) ligation at the equatorial positions and likely a fifth R-CO2(-) ligation at the axial position. Small differences in the thermal decomposition pathway between the gel containing citrato-oxalato-VO(2+) complexes and the oxalate-free gel containing citrato-VO(2+) complexes are observed between 150 and 200 °C in air and are assigned to the presence of (NH4)2C2O4 in the citrato-oxalato-VO(2+) solution. Both precursor solutions are successfully used for the formation of crystalline vanadium oxide nanostructures on SiO2, after thermal annealing at 500 °C in a 0.1% O2 atmosphere. However, the citrato-oxalato-VO(2+) and the oxalate-free citrato-VO(2+) solution result in the formation of monoclinic V6O13 and monoclinic VO2, respectively.

  11. Vanadyl (IV) and vanadate (V) binding to selected endogenous phosphate, carboxyl, and amino ligands; calculations of cellular vanadium species distribution.

    PubMed

    Nechay, B R; Nanninga, L B; Nechay, P S

    1986-11-15

    Vanadium enters cells as vanadate (V) where it is reduced to vanadyl (IV), VO2+. Vanadate species at plasma pH, H2VO4-, and HVO4(2-) are referred to as VO3-. To gain an insight into the subcellular vanadium distribution we measured the binding of VO3- and VO2+ to extra- and intracellular ligands, and calculated free and bound fractions of these ions for expected in vivo conditions. The association constants (K) were determined by the pH shift caused by an addition of VOSO4 or NaVO3 to individual ligand solutions at 20 degrees C and a pH equal to the pK of the reactive groups. The pk's for binding of VO2+ were ATP, 5.9; ADP, 5.5; AMP, 5.1; Pi 4.3; creatine phosphate (CP), 3.6; glutamic acid, 3.4; aspartic acid, 3.1; human serum albumin, 3.1; glutathione, 2.7; ascorbic acid, 3.3; citric acid, 4.0. The pk of VO3- and human serum albumin was 3.3 and of that VO3- and glutathione was 4.2. VO3- did not bind to ATP, even via Mg2+ or Ca2+ bridges. We calculated that in cells approximately 1% of total VO2+ is unbound, which is 10(-10)-10(-9) M since published values for total vanadium (mainly VO2+) concentrations in tissues are on the order of 10(-8)-10(-7) M. Free VO2+ may be even less because of binding to additional ligands not considered and due to spontaneous hydrolysis to VOOH+ and VO(OH)2(2+) at intracellular pH. The binding of VO2+ to each ligand was corrected for presence of multiple ligands and competition by H+, K+, and Mg2+. In cells with no CP, up to 70% of VO2+ is bound to phosphates and up to 29% to proteins; in cells with 30 mM CP (as in muscle), approximately 95% is bound to phosphates (CP binds up to 61% of total VO2+) and approximately 4% to proteins; in cells with 2 mM ascorbic acid (as in brain), the vitamin binds approximately 3% of total VO2+. These binding values apply for the total VO2+ concentration range of 10(-8)-10(-5) M. The intracellular binding and a reducing environment protect the freshly reduced VO2+ from oxidation to VO3- that would otherwise occur at neutral pH. This strong affinity of VO2+ primarily for phosphates also explains the mechanism for the intracellular accumulation of vanadium which is a factor in previously observed transport of VO3- into cells.(ABSTRACT TRUNCATED AT 400 WORDS)

  12. Enhancement Strategies for Frame-To Uas Stereo Visual Odometry

    NASA Astrophysics Data System (ADS)

    Kersten, J.; Rodehorst, V.

    2016-06-01

    Autonomous navigation of indoor unmanned aircraft systems (UAS) requires accurate pose estimations usually obtained from indirect measurements. Navigation based on inertial measurement units (IMU) is known to be affected by high drift rates. The incorporation of cameras provides complementary information due to the different underlying measurement principle. The scale ambiguity problem for monocular cameras is avoided when a light-weight stereo camera setup is used. However, also frame-to-frame stereo visual odometry (VO) approaches are known to accumulate pose estimation errors over time. Several valuable real-time capable techniques for outlier detection and drift reduction in frame-to-frame VO, for example robust relative orientation estimation using random sample consensus (RANSAC) and bundle adjustment, are available. This study addresses the problem of choosing appropriate VO components. We propose a frame-to-frame stereo VO method based on carefully selected components and parameters. This method is evaluated regarding the impact and value of different outlier detection and drift-reduction strategies, for example keyframe selection and sparse bundle adjustment (SBA), using reference benchmark data as well as own real stereo data. The experimental results demonstrate that our VO method is able to estimate quite accurate trajectories. Feature bucketing and keyframe selection are simple but effective strategies which further improve the VO results. Furthermore, introducing the stereo baseline constraint in pose graph optimization (PGO) leads to significant improvements.

  13. Epitaxial stabilization and phase instability of VO2 polymorphs

    NASA Astrophysics Data System (ADS)

    Lee, Shinbuhm; Ivanov, Ilia N.; Keum, Jong K.; Lee, Ho Nyung

    2016-01-01

    The VO2 polymorphs, i.e., VO2(A), VO2(B), VO2(M1) and VO2(R), have a wide spectrum of functionalities useful for many potential applications in information and energy technologies. However, synthesis of phase pure materials, especially in thin film forms, has been a challenging task due to the fact that the VO2 polymorphs are closely related to each other in a thermodynamic framework. Here, we report epitaxial stabilization of the VO2 polymorphs to synthesize high quality single crystalline thin films and study the phase stability of these metastable materials. We selectively deposit all the phases on various perovskite substrates with different crystallographic orientations. By investigating the phase instability, phonon modes and transport behaviours, not only do we find distinctively contrasting physical properties of the VO2 polymorphs, but that the polymorphs can be on the verge of phase transitions when heated as low as ~400 °C. Our successful epitaxy of both VO2(A) and VO2(B) phases, which are rarely studied due to the lack of phase pure materials, will open the door to the fundamental studies of VO2 polymorphs for potential applications in advanced electronic and energy devices.

  14. Epitaxial stabilization and phase instability of VO2 polymorphs.

    PubMed

    Lee, Shinbuhm; Ivanov, Ilia N; Keum, Jong K; Lee, Ho Nyung

    2016-01-20

    The VO2 polymorphs, i.e., VO2(A), VO2(B), VO2(M1) and VO2(R), have a wide spectrum of functionalities useful for many potential applications in information and energy technologies. However, synthesis of phase pure materials, especially in thin film forms, has been a challenging task due to the fact that the VO2 polymorphs are closely related to each other in a thermodynamic framework. Here, we report epitaxial stabilization of the VO2 polymorphs to synthesize high quality single crystalline thin films and study the phase stability of these metastable materials. We selectively deposit all the phases on various perovskite substrates with different crystallographic orientations. By investigating the phase instability, phonon modes and transport behaviours, not only do we find distinctively contrasting physical properties of the VO2 polymorphs, but that the polymorphs can be on the verge of phase transitions when heated as low as ~400 °C. Our successful epitaxy of both VO2(A) and VO2(B) phases, which are rarely studied due to the lack of phase pure materials, will open the door to the fundamental studies of VO2 polymorphs for potential applications in advanced electronic and energy devices.

  15. Epitaxial stabilization and phase instability of VO2 polymorphs

    PubMed Central

    Lee, Shinbuhm; Ivanov, Ilia N.; Keum, Jong K.; Lee, Ho Nyung

    2016-01-01

    The VO2 polymorphs, i.e., VO2(A), VO2(B), VO2(M1) and VO2(R), have a wide spectrum of functionalities useful for many potential applications in information and energy technologies. However, synthesis of phase pure materials, especially in thin film forms, has been a challenging task due to the fact that the VO2 polymorphs are closely related to each other in a thermodynamic framework. Here, we report epitaxial stabilization of the VO2 polymorphs to synthesize high quality single crystalline thin films and study the phase stability of these metastable materials. We selectively deposit all the phases on various perovskite substrates with different crystallographic orientations. By investigating the phase instability, phonon modes and transport behaviours, not only do we find distinctively contrasting physical properties of the VO2 polymorphs, but that the polymorphs can be on the verge of phase transitions when heated as low as ~400 °C. Our successful epitaxy of both VO2(A) and VO2(B) phases, which are rarely studied due to the lack of phase pure materials, will open the door to the fundamental studies of VO2 polymorphs for potential applications in advanced electronic and energy devices. PMID:26787259

  16. Prevention of Hippocampal Neuronal Damage and Cognitive Function Deficits in Vascular Dementia by Dextromethorphan.

    PubMed

    Xu, Xiaofeng; Zhang, Bin; Lu, Kaili; Deng, Jiangshan; Zhao, Fei; Zhao, Bing-Qiao; Zhao, Yuwu

    2016-07-01

    Dextromethorphan (DM) is a non-competitive antagonist of NMDA receptors and a widely used component of cough medicine. Recently, its indication has been extended experimentally to a wide range of disorders including inflammation-mediated central nervous system disorders such as Parkinson disease (PD) and multiple sclerosis (MS). In this study, we investigate whether DM treatment has protective effects on the hippocampal neuron damage induced by bilateral occlusion of the common carotid arteries (two-vessel occlusion [2VO]), an animal model of vascular dementia (VaD). Sprague-Dawley (SD) (10 weeks of age) rats were subjected to the 2VO, and DM was injected intraperitoneally once per day for 37 days. Neuron death, glial activation, and cognitive function were assessed at 37 days after 2VO (0.2 mg/kg, i.p., "DM-0.2" and 2 mg/kg, i.p., "DM-2"). DM-2 treatment provided protection against neuronal death and glial activation in the hippocampal CA1 subfield and reduced cognitive impairment induced by 2VO in rats. The study also demonstrates that activation of the Nrf2-HO-1 pathway and upregulation of superoxide dismutase (SOD) play important roles in these effects. These results suggest that DM is effective in treating VaD and protecting against oxidative stress, which is strongly implicated in the pathogenesis of VaD. Therefore, the present study suggests that DM treatment may represent a new and promising protective strategy for treating VaD.

  17. Association between aerobic fitness and indices of autonomic regulation: cardiovascular risk implications.

    PubMed

    Sala, Roberto; Malacarne, Mara; Pagani, Massimo; Lucini, Daniela

    2016-06-01

    In the general population higher levels of exercise capacity seem to protect the cardiovascular system with effects well beyond traditional risk factors. We hypothesize that this phenomenon, called "risk factor gap", could be ascribed to functional components, such as autonomic adaptation to aerobic training. In 257 subjects (age 36.2±0.8 years) we measured VO2peak (incremental cycling exercise), together with arterial pressure and autonomic proxies (baroreflex gain, R-R variance and standing induced increase in marker of excitatory oscillatory regulation of the SA node, ∆LFRRnu). Autonomic proxies appeared significantly correlated with indicators of aerobic fitness (age and gender corrected correlation between VO2peak, baroreflex gain: r=0.277, P<0.001, and DAP r=-0.228, P<0.001). Subsequently, subjects were subdivided in three age and gender adjusted categories of VO2peak (poor, medium and good). Autonomic indices and arterial pressure appeared significantly ordered with categories of VO2peak (P<0.006). In addition, within these categories the proportion of subjects with a desirable autonomic and pressure profile becomes significantly greater with better fitness levels. The strong ordered relationship between categories of aerobic fitness and autonomic proxies speaks in favor of a complementary role of the autonomic nervous system in the management of cardiovascular risk factor gap at a population level.

  18. Is Recreational Soccer Effective for Improving VO2max A Systematic Review and Meta-Analysis.

    PubMed

    Milanović, Zoran; Pantelić, Saša; Čović, Nedim; Sporiš, Goran; Krustrup, Peter

    2015-09-01

    Soccer is the most popular sport worldwide, with a long history and currently more than 500 million active participants, of whom 300 million are registered football club members. On the basis of scientific findings showing positive fitness and health effects of recreational soccer, FIFA (Fédération Internationale de Football Association) introduced the slogan "Playing football for 45 min twice a week-best prevention of non-communicable diseases" in 2010. The objective of this paper was to perform a systematic review and meta-analysis of the literature to determine the effects of recreational soccer on maximal oxygen uptake (VO2max). Six electronic databases (MEDLINE, PubMed, SPORTDiscus, Web of Science, CINAHL and Google Scholar) were searched for original research articles. A manual search was performed to cover the areas of recreational soccer, recreational physical activity, recreational small-sided games and VO2max using the following key terms, either singly or in combination: recreational small-sided games, recreational football, recreational soccer, street football, street soccer, effect, maximal oxygen uptake, peak oxygen uptake, cardiorespiratory fitness, VO2max. The inclusion criteria were divided into four sections: type of study, type of participants, type of interventions and type of outcome measures. Probabilistic magnitude-based inferences for meta-analysed effects were based on standardised thresholds for small, moderate and large changes (0.2, 0.6 and 1.2, respectively) derived from between-subject standard deviations for baseline fitness. Seventeen studies met the inclusion criteria and were included in the systematic review and meta-analysis. Mean differences showed that VO2max increased by 3.51 mL/kg/min (95 % CI 3.07-4.15) over a recreational soccer training programme in comparison with other training models. The meta-analysed effects of recreational soccer on VO2max compared with the controls of no exercise, continuous running and strength training were most likely largely beneficial [effect size (ES) = 1.46; 95 % confidence interval (CI) 0.91, 2.01; I (2) = 88.35 %], most likely moderately beneficial (ES = 0.68; 95 % CI 0.06, 1.29; I (2) = 69.13 %) and most likely moderately beneficial (ES = 1.08; 95 % CI -0.25, 2.42; I (2) = 71.06 %), respectively. In men and women, the meta-analysed effect was most likely largely beneficial for men (ES = 1.22) and most likely moderately beneficial for women (ES = 0.96) compared with the controls. After 12 weeks of recreational soccer with an intensity of 78-84 % maximal heart rate (HRmax), healthy untrained men improved their VO2max by 8-13 %, while untrained elderly participants improved their VO2max by 15-18 %. Soccer training for 12-70 weeks in healthy women resulted in an improvement in VO2max of 5-16 %. Significant improvements in VO2max have been observed in patients with diabetes mellitus, hypertension and prostate cancer. Recreational soccer produces large improvements in VO2max compared to strength training and no exercise, regardless of the age, sex and health status of the participants. Furthermore, recreational soccer is better than continuous endurance running, albeit the additional effect is moderate. This kind of physical activity has great potential for enhancing aerobic fitness, and for preventing and treating non-communicable diseases, and is ideal for addressing lack of motivation, a key component in physical (in)activity.

  19. Dynamical heat transport amplification in a far-field thermal transistor of VO{sub 2} excited with a laser of modulated intensity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ordonez-Miranda, Jose, E-mail: jose.ordonez@cnrs.pprime.fr; Ezzahri, Younès; Drevillon, Jérémie

    2016-05-28

    Far-field radiative heat transport in a thermal transistor made up of a vanadium dioxide base excited with a laser of modulated intensity is analytically studied and optimized. This is done by solving the equation of energy conservation for the steady-state and modulated components of the temperature and heat fluxes that the base exchanges with the collector and emitter. The thermal bistability of VO{sub 2} is used to find an explicit condition on the laser intensity required to maximize these heat fluxes to values higher than the incident flux. For a 1 μm-thick base heated with a modulation frequency of 0.5 Hz, itmore » is shown that both the DC and AC components of the heat fluxes are about 4 times the laser intensity, while the AC temperature remains an order of magnitude smaller than the DC one at around 343 K. Higher AC heat fluxes are obtained for thinner bases and/or lower frequencies. Furthermore, we find that out of the bistability temperatures associated with the dielectric-to-metal and metal-to-dielectric transitions of VO{sub 2}, the amplification of the collector-to-base and base-to-emitter heat fluxes is still possible, but at modulation frequencies lower than 0.1 Hz.« less

  20. Integration of the physiological factors determining endurance performance ability.

    PubMed

    Coyle, E F

    1995-01-01

    This model is used to understand the interrelationships of the physiological factors determining endurance performance ability during prolonged exercise. Early studies found that marathon runners maintain a velocity in competition that corresponds to the intensity at which lactate begins to accumulate in blood and muscle [7, 8, 19]. From this observation, the concept developed that this blood lactate threshold (LT Vo2) reflects the degree of muscular stress, glycogenolysis and fatigue. However, it was not clear whether the lactate accumulation was a result of cardiovascular limitations linked to oxygen delivery, as reflected by Vo2max [54], as opposed to metabolic factors in the exercising muscle related to the extent to which mitochondrial respiration is disturbed to maintain a given rate of O2 consumption [29, 30]. Two studies were performed to determine whether LT Vo2 was tightly coupled to Vo2max. In one study, endurance-trained ischemic heart disease patients were observed to possess a Vo2max that was 18% below that of normal master athletes who followed the patient's training program and who displayed the same performance ability as the patients. Both the patients and the normal men displayed an identical LT Vo2 (i.e., 37 ml/kg/min) (Fig. 2.5). Therefore, performance was determined primarily by LT Vo2 instead of Vo2max in this situation, albeit with abnormal subjects. In a second study we assembled two groups of competitive cyclists who were identical in Vo2max but differed by having a high or low LT Vo2 (82% vs. 66% Vo2max) [13]. When cycling at 80-88% Vo2max, the low LT group displayed more than a 2-fold higher rate of muscle glycogen use and blood lactate concentration, and as a result were able to exercise only one-half as long as the high LT group. Performance time for a given Vo2 was clearly related to LT Vo2 instead of Vo2max (Fig. 2.6). This is not to say that Vo2max plays no role in determining LT Vo2, because as in heart disease patients, it clearly sets the upper limit. Indeed, we have seen that much of the variance (i.e., 31-72%) in LT Vo2 is related to Vo2max. (Fig. 2.11.) However, improvements in performance after the first 2-3 yr of intense training are associated with improvements in LT Vo2, whereas Vo2max generally increases very little thereafter (Table 2.3). The next question concerns the factors responsible for further increases in LT Vo2 and Performance. Another major factor determining LT Vo2 is the muscle's Aerobic Enzyme Activity or mitochondrial respiratory capacity, as discussed in previous reviews [29, 30].(ABSTRACT TRUNCATED AT 400 WORDS)

  1. Genetic Obesity Risk and Attenuation Effect of Physical Fitness in Mexican-Mestizo Population: a Case-Control Study.

    PubMed

    Costa-Urrutia, Paula; Abud, Carolina; Franco-Trecu, Valentina; Colistro, Valentina; Rodríguez-Arellano, Martha Eunice; Vázquez-Pérez, Joel; Granados, Julio; Seelaender, Marilia

    2017-05-01

    We analyzed commonly reported European and Asian obesity-related gene variants in a Mexican-Mestizo population through each single nucleotide polymorphism (SNP) and a genetic risk score (GRS) based on 23 selected SNPs. Study subjects were physically active Mexican-Mestizo adults (n  =  608) with body mass index (BMI) values from 18 to 55 kg/m 2 . For each SNP and for the GRS, logistic models were performed to test for simple SNP associations with BMI, fat mass percentage (FMP), waist circumference (WC), and the interaction with VO 2max and muscular endurance (ME). To further understand the SNP or GRS*physical fitness components, generalized linear models were performed. Obesity risk was significantly associated to 6 SNPs (ADRB2 rs1042713, APOB rs512535, PPARA rs1800206, TNFA rs361525, TRHR rs7832552 and rs16892496) after adjustment by gender, age, ancestry, VO 2max , and ME. ME attenuated the influence of APOB rs512535 and TNFA rs361525 on obesity risk in FMP. WC was significantly associated to GRS. Both ME and VO 2max attenuated GRS effect on WC. We report associations for 6 out of 23 SNPs and for the GRS, which confer obesity risk, a novel finding for Mexican-Mestizo physically active population. Also, the importance of including physical fitness components variables in obesity genetic risk studies is highlighted, with special regard to intervention purposes. © 2017 John Wiley & Sons Ltd/University College London.

  2. Impact of High-intensity Intermittent and Moderate-intensity Continuous Exercise on Autonomic Modulation in Young Men.

    PubMed

    Cabral-Santos, C; Giacon, T R; Campos, E Z; Gerosa-Neto, J; Rodrigues, B; Vanderlei, L C M; Lira, F S

    2016-06-01

    The aim of this study was to compare heart rate variability (HRV) recovery after two iso-volume (5 km) exercises performed at different intensities. 14 subjects volunteered (25.17±5.08 years; 74.7±6.28 kg; 175±0.05 cm; 59.56±5.15 mL·kg(-1)·min(-1)) and after determination of peak oxygen uptake (VO2Peak) and the speed associated with VO2Peak (sVO2Peak), the subjects completed 2 random experimental trials: high-intensity exercise (HIE - 1:1 at 100% sVO2Peak), and moderate-intensity continuous exercise (MIE - 70% sVO2Peak). HRV and RR intervals were monitored before, during and after the exercise sessions together with, the HRV analysis in the frequency domains (high-frequency - HF: 0.15 to 0.4 Hz and low-frequency - LF: 0.04 to 0.15 Hz components) and the ratio between them (LF/HF). Statistical analysis comparisons between moments and between HIE and MIE were performed using a mixed model. Both exercise sessions modified LFlog, HFlog, and LF/HF (F=16.54, F=19.32 and F=5.17, p<0.05, respectively). A group effect was also found for LFlog (F=23.91, p<0.05), and HFlog (F=57.55, p< 0.05). LF/HF returned to resting value 15 min after MIE exercise and 20 min after HIE exercise. This means that the heavy domain (aerobic and anaerobic threshold) induces dissimilar autonomic modification in physically active subjects. Both HIE and MIE modify HRV, and generally HIE delays parasympathetic autonomic modulation recovery after iso-volume exercise. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Gross efficiency and energy expenditure in kayak ergometer exercise.

    PubMed

    Gomes, B B; Mourão, L; Massart, A; Figueiredo, P; Vilas-Boas, J P; Santos, A M C; Fernandes, R J

    2012-08-01

    We purposed to study energy expenditure, power output and gross efficiency during kayak ergometer exercise in 12 elite sprint kayakers. 6 males (age 24.2±4.8 years, height 180.4±4.8 cm, body mass 79.7±8.5 kg) and 6 females (age 24.3±4.5 years, height 164.5±3.9 cm, body mass 65.4±3.5 kg), performed an incremental intermittent protocol on kayak ergometer with VO2 and blood lactate concentration assessment, a non-linear increase between power output and energy expenditure being observed. Paddling power output, energy expenditure and gross efficiency corresponding to VO2max averaged 199.92±50.41 W, 75.27±6.30 ml.kg - 1.min - 1, and 10.10±1.08%. Male kayakers presented higher VO2max, power output and gross efficiency at the VO2max, and lower heart rate and maximal lactate concentration than females, but no differences were found between genders regarding energy expenditure at VO2max. Aerobic and anaerobic components of energy expenditure evidenced a significant contribution of anaerobic energy sources in sprint kayak performance. Results also suggested the dependence of the gross efficiency on the changes in the amount of the aerobic and anaerobic contributions, at heavy and severe intensities. The inter-individual variance of the relationship between energy expenditure and the corresponding paddling power output revealed a relevant tracking for females (FDγ=0.73±0.06), conversely to the male group (FDγ=0.27±0.08), supporting that some male kayakers are more skilled in some paddling intensities than others. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Effect of limb cooling on peripheral and global oxygen consumption in neonates

    PubMed Central

    Hassan, I; Wickramasinghe, Y; Spencer, S

    2003-01-01

    Aim: To evaluate peripheral oxygen consumption (VO2) measurements using near infrared spectroscopy (NIRS) with arterial occlusion in healthy term neonates by studying the effect of limb cooling on peripheral and global VO2. Subjects and methods: Twenty two healthy term neonates were studied. Peripheral VO2 was measured by NIRS using arterial occlusion and measurement of the oxyhaemoglobin (HbO2) decrement slope. Global VO2 was measured by open circuit calorimetry. Global and peripheral VO2 was measured in each neonate before and after limb cooling. Results: In 10 neonates, a fall in forearm temperature of 2.2°C (mild cooling) decreased forearm VO2 by 19.6% (p < 0.01). Global VO2 did not change. In 12 neonates, a fall in forearm temperature of 4°C (moderate cooling) decreased forearm VO2 by 34.7% (p < 0.01). Global VO2 increased by 17.6% (p < 0.05). Conclusions: The NIRS arterial occlusion method is able to measure changes in peripheral VO2 induced by limb cooling. The changes are more pronounced with moderate limb cooling when a concomitant rise in global VO2 is observed. Change in peripheral temperature must be taken into consideration in the interpretation of peripheral VO2 measurements in neonates. PMID:12598504

  5. Effect of limb cooling on peripheral and global oxygen consumption in neonates.

    PubMed

    Hassan, I A-A; Wickramasinghe, Y A; Spencer, S A

    2003-03-01

    To evaluate peripheral oxygen consumption (VO(2)) measurements using near infrared spectroscopy (NIRS) with arterial occlusion in healthy term neonates by studying the effect of limb cooling on peripheral and global VO(2). Twenty two healthy term neonates were studied. Peripheral VO(2) was measured by NIRS using arterial occlusion and measurement of the oxyhaemoglobin (HbO(2)) decrement slope. Global VO(2) was measured by open circuit calorimetry. Global and peripheral VO(2) was measured in each neonate before and after limb cooling. In 10 neonates, a fall in forearm temperature of 2.2 degrees C (mild cooling) decreased forearm VO(2) by 19.6% (p < 0.01). Global VO(2) did not change. In 12 neonates, a fall in forearm temperature of 4 degrees C (moderate cooling) decreased forearm VO(2) by 34.7% (p < 0.01). Global VO(2) increased by 17.6% (p < 0.05). The NIRS arterial occlusion method is able to measure changes in peripheral VO(2) induced by limb cooling. The changes are more pronounced with moderate limb cooling when a concomitant rise in global VO(2) is observed. Change in peripheral temperature must be taken into consideration in the interpretation of peripheral VO(2) measurements in neonates.

  6. Study on Thermochromic VO2 Films Grown on ZnO-Coated Glass Substrates for “Smart Windows”

    NASA Astrophysics Data System (ADS)

    Kato, Kazuhiro; Song, Pung Keun; Odaka, Hidehumi; Shigesato, Yuzo

    2003-10-01

    Vanadium dioxide (VO2) is one of the most attractive thermochromic materials, which show large changes in optical and electrical properties at the transition temperature (Tt) close to the atmospheric temperature (approximately 340 K). We already reported for VO2 deposition by rf magnetron sputtering using V2O3 or V2O5 targets that VO2 films thicker than 400 nm showed high thermochromic performance, whereas the VO2 films thinner than 200 nm did not show such performance because of their poor crystallinity and off-stoichiometry. In this study, very thin thermochromic VO2 films with thicknesses of about 50 nm were successfully deposited using highly < 001>-preferred oriented ZnO polycrystalline films as a buffer layer between the VO2 film and glass substrate (VO2/ZnO/glass) because of the heteroepitaxial growth of VO2 polycrystalline films. W-doped VO2 films were also deposited on the ZnO-coated glass substrates (ZnO/glass) by cosputtering. It was confirmed that W doping for thin VO2 films deposited on the ZnO/glass can decrease Tt systematically. Such very thin VO2 films should have high potential for application in “smart windows”.

  7. IR studies of the impact of Ge doping on the successive conversion of VOn defects in Czochralski-Si containing carbon

    NASA Astrophysics Data System (ADS)

    Londos, C. A.; Andrianakis, A.; Sgourou, E. N.; Emtsev, V. V.; Ohyama, H.

    2011-02-01

    We report infrared absorption studies of oxygen-related defects in electron-irradiated Ge-doped Czochralski-Si. Our investigation was mainly focused on the reaction channel leading to the formation of VOn (1≤n≤6) defects. The VOn defects form mainly upon annealing, as a result of the successive aggregation of oxygen atoms in the initial VO defect produced by the irradiation: (VO+Oi→VO2+Oi→VO3+Oi→VO4,…). It was found that the ratio of the conversion of VOn to VOn+1 defects is sensitive to the Ge content of the material. In particular, the ratio of the conversion of the VO to the VO2 defects was found to decrease with the increase in Ge concentration of the samples, although the opposite trend was observed for the VO3 to VO4 conversion. However, the VO2 to VO3 conversion changes only slightly with Ge content, being practically unaffected for Ge concentrations up to 2×1020 cm-3. In the case of VO2 formation, the phenomenon was attributed to the elastic strains induced in the lattice due to the Ge presence which affects the balance between the reactions VO+Oi→VO2, VO+SiI→Oi, mainly involved in the decay of the VO and the growth of the VO2 defects. In the case of VO4 formation, the phenomenon was discussed by taking into account the enhancement of the diffusivity of the Oi atoms in the Ge-doped Si, which could lead to an enhancement of the rate of the reaction VO3+Oi→VO4. For the VO3 formation this effect is practically negligible due to the fact that at the temperatures of VO2 to VO3 conversion oxygen diffusivity is quite small. The exhibited behavior in the conversion of the VOn to VOn+1 defects (n=1,2,3) was similar in Ge-doped samples with low carbon content ([Cs]<2×1016 cm-3) and in Ge-doped samples with high carbon content ([Cs]≥1×1017 cm-3). The impact of C as well as its role in the conversion efficiency of VO to VO2 was studied by comparing the spectra in low carbon and high carbon Ge free Si material. Furthermore, a pair of bands at (1037,1051 cm-1) was attributed to the VO5 defect. The origin of another pair of bands (967,1005 cm-1) was discussed and tentatively correlated with a VOnCs structure. The role of Ge and C in the formation of the latter two pairs of bands was discussed.

  8. Rapid hydrothermal synthesis of VO2 (B) and its conversion to thermochromic VO2 (M1).

    PubMed

    Popuri, Srinivasa Rao; Miclau, Marinela; Artemenko, Alla; Labrugere, Christine; Villesuzanne, Antoine; Pollet, Michaël

    2013-05-06

    The present study provides a rapid way to obtain VO2 (B) under economical and environmentally friendly conditions. VO2 (B) is one of the well-known polymorphs of vanadium dioxide and is a promising cathode material for aqueous lithium ion batteries. VO2 (B) was successfully synthesized by rapid single-step hydrothermal process using V2O5 and citric acid as precursors. The present study shows that phase-pure VO2 (B) polytype can be easily obtained at 180 °C for 2 h and 220 °C for 1 h, that is, the lowest combination of temperature and duration reported so far. The obtained VO2 (B) is characterized by X-ray powder diffraction, high-resolution scanning electron microscopy, and Fourier transform infrared spectroscopy. In addition, we present an indirect way to obtain VO2 (M1) by annealing VO2 (B) under vacuum for 1 h.

  9. Epitaxial stabilization and phase instability of VO 2 polymorphs

    DOE PAGES

    Lee, Shinbuhm; Ivanov, Ilia N.; Keum, Jong K.; ...

    2016-01-20

    The VO 2 polymorphs, i.e., VO 2(A), VO 2(B), VO 2(M1) and VO 2(R), have a wide spectrum of functionalities useful for many potential applications in information and energy technologies. However, synthesis of phase pure materials, especially in thin film forms, has been a challenging task due to the fact that the VO 2 polymorphs are closely related to each other in a thermodynamic framework. Here, we report epitaxial stabilization of the VO 2 polymorphs to synthesize high quality single crystalline thin films and study the phase stability of these metastable materials. We selectively deposit all the phases on variousmore » perovskite substrates with different crystallographic orientations. By investigating the phase instability, phonon modes and transport behaviours, not only do we find distinctively contrasting physical properties of the VO 2 polymorphs, but that the polymorphs can be on the verge of phase transitions when heated as low as ~400 °C. In conclusion, our successful epitaxy of both VO 2(A) and VO 2(B) phases, which are rarely studied due to the lack of phase pure materials, will open the door to the fundamental studies of VO 2 polymorphs for potential applications in advanced electronic and energy devices.« less

  10. A novel inorganic precipitation-peptization method for VO2 sol and VO2 nanoparticles preparation: Synthesis, characterization and mechanism.

    PubMed

    Li, Yao; Jiang, Peng; Xiang, Wei; Ran, Fanyong; Cao, Wenbin

    2016-01-15

    In this paper, a simple, safe and cost-saving precipitation-peptization method was proposed to prepare VO2 sol by using inorganic VOSO4-NH3⋅H2O-H2O2 reactants system in air under room temperature. In this process, VOSO4 was firstly precipitated to form VO(OH)2, then monometallic species of VO(O2)(OH)(-) were formed through the coordination between VO(OH)2 and H2O2. The rearrangement of VO(O2)(OH)(-) in a nonplanar pattern and intermolecular condensation reactions result in multinuclear species. Finally, VO2 sol is prepared through the condensation reactions between the multinuclear species. After drying the obtained sol at 40°C, VO2 xerogel exhibiting monoclinic crystal structure with the space group of C2/m was prepared. The crystal structure of VO2 nanoparticles was transferred to monoclinic crystal structure with the space group of P21/c (VO2(M)) by annealing the xerogel at 550°C. Both XRD and TEM analysis indicated that the nanoparticles possess good crystallinity with crystallite size of 34.5nm as estimated by Scherrer's method. These results suggest that the VO2 sol has been prepared successfully through the proposed simple method. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Effect of speed endurance training and reduced training volume on running economy and single muscle fiber adaptations in trained runners.

    PubMed

    Skovgaard, Casper; Christiansen, Danny; Christensen, Peter M; Almquist, Nicki W; Thomassen, Martin; Bangsbo, Jens

    2018-02-01

    The aim of the present study was to examine whether improved running economy with a period of speed endurance training and reduced training volume could be related to adaptations in specific muscle fibers. Twenty trained male (n = 14) and female (n = 6) runners (maximum oxygen consumption (VO 2 -max): 56.4 ± 4.6 mL/min/kg) completed a 40-day intervention with 10 sessions of speed endurance training (5-10 × 30-sec maximal running) and a reduced (36%) volume of training. Before and after the intervention, a muscle biopsy was obtained at rest, and an incremental running test to exhaustion was performed. In addition, running at 60% vVO 2 -max, and a 10-km run was performed in a normal and a muscle slow twitch (ST) glycogen-depleted condition. After compared to before the intervention, expression of mitochondrial uncoupling protein 3 (UCP3) was lower (P < 0.05) and dystrophin was higher (P < 0.05) in ST muscle fibers, and sarcoplasmic reticulum calcium ATPase 1 (SERCA1) was lower (P < 0.05) in fast twitch muscle fibers. Running economy at 60% vVO 2 -max (11.6 ± 0.2 km/h) and at v10-km (13.7 ± 0.3 km/h) was ~2% better (P < 0.05) after the intervention in the normal condition, but unchanged in the ST glycogen-depleted condition. Ten kilometer performance was improved (P < 0.01) by 3.2% (43.7 ± 1.0 vs. 45.2 ± 1.2 min) and 3.9% (45.8 ± 1.2 vs. 47.7 ± 1.3 min) in the normal and the ST glycogen-depleted condition, respectively. VO 2 -max was the same, but vVO 2 -max was 2.0% higher (P < 0.05; 19.3 ± 0.3 vs. 18.9 ± 0.3 km/h) after than before the intervention. Thus, improved running economy with intense training may be related to changes in expression of proteins linked to energy consuming processes in primarily ST muscle fibers. © 2018 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  12. A Forty-Year Follow-Up of the Dallas Bed Rest and Training Study: The Effect of Age on the Cardiovascular Response to Exercise in Men

    PubMed Central

    McGavock, Jonathan M.; Hastings, Jeffrey L.; Snell, Peter G.; McGuire, Darren K.; Pacini, Eric L.; Mitchell, Jere H.

    2009-01-01

    Background In 1966, five 20-year-old men underwent a comprehensive physiological evaluation of the capacity for adaptation of the cardiovascular system in response to 3 weeks of bed rest and 8 weeks of heavy endurance training; these same participants were reevaluated before and after training at the age of 50. The aim of the present study was to reexamine these same men 40 years following the original assessments. Methods and Results In all three studies, minute ventilation and expired gases were analyzed during exercise testing with Douglas bag collection. Cardiac output (CO) was determined using the acetylene rebreathing technique. Compared with the original 30-year interval, the decline in maximal oxygen uptake (VO2max) (−11% vs −25%), maximal CO (+6% vs −11%), and maximal stroke volume (+10% vs −10%) were greater between 50 and 60 years of age. The annualized decline in VO2max (55 mL/min/y) between ages 50 and 60 was approximately fourfold higher than the decline between 20 and 50 years (12 mL/min/y). Conclusions In the original five participants of the Dallas Bed Rest and Training Study, VO2max declined after 40 years of living due to a balanced decrease in central and peripheral determinants of oxygen uptake. The rate of decline in VO2max and its components accelerated after the age of 50 years secondary to age and clinical comorbidities. The net proportional decline in VO2max for a period of 40 years of life was comparable with that experienced after 3 weeks of strict bed rest at the age of 20 (27% vs 26%, respectively). PMID:19196908

  13. Ventilatory threshold may be a more specific measure of aerobic capacity than peak oxygen consumption rate in persons with stroke.

    PubMed

    Boyne, Pierce; Reisman, Darcy; Brian, Michael; Barney, Brian; Franke, Ava; Carl, Daniel; Khoury, Jane; Dunning, Kari

    2017-03-01

    After stroke, aerobic deconditioning can have a profound impact on daily activities. This is usually measured by the peak oxygen consumption rate achieved during exercise testing (VO2-peak). However, VO2-peak may be distorted by motor function. The oxygen uptake efficiency slope (OUES) and VO2 at the ventilatory threshold (VO2-VT) could more specifically assess aerobic capacity after stroke, but this has not been tested. To assess the differential influence of motor function on three measures of aerobic capacity (VO2-peak, OUES, and VO2-VT) and to evaluate the inter-rater reliability of VO2-VT determination post-stroke. Among 59 persons with chronic stroke, cross-sectional correlations with motor function (comfortable gait speed [CGS] and lower extremity Fugl-Meyer [LEFM]) were compared between the different aerobic capacity measures, after adjustment for covariates, in order to isolate any distorting effect of motor function. Reliability of VO2-VT determination between three raters was assessed with intra-class correlation (ICC). CGS was moderately correlated with VO2-peak (r = 0.52, p < 0.0001) and weakly correlated with OUES (r = 0.41, p = 0.002) and VO2-VT (r = 0.37, p = 0.01). LEFM was weakly correlated with VO2-peak (r = 0.26, p = 0.055) and very weakly correlated with OUES (r = 0.19, p = 0.17) and VO2-VT (r = 0.14, p = 0.31). Compared to VO2-peak, VO2-VT was significantly less correlated with CGS (r difference = -0.16, p = 0.02). Inter-rater reliability of VO2-VT determination was high (ICC: 0.93, 95% CI: 0.89-0.96). Motor dysfunction appears to artificially lower measured aerobic capacity. VO2-VT seemed to be less distorted than VO2-peak and had good inter-rater reliability, so it may provide more specific assessment of aerobic capacity post-stroke.

  14. Modeling and analysis of the effect of training on V O2 kinetics and anaerobic capacity.

    PubMed

    Stirling, J R; Zakynthinaki, M S; Billat, V

    2008-07-01

    In this paper, we present an application of a number of tools and concepts for modeling and analyzing raw, unaveraged, and unedited breath-by-breath oxygen uptake data. A method for calculating anaerobic capacity is used together with a model, in the form of a set of coupled nonlinear ordinary differential equations to make predictions of the VO(2) kinetics, the time to achieve a percentage of a certain constant oxygen demand, and the time limit to exhaustion at intensities other than those in which we have data. Speeded oxygen kinetics and increased time limit to exhaustion are also investigated using the eigenvalues of the fixed points of our model. We also use a way of analyzing the oxygen uptake kinetics using a plot of V O(2)(t) vs V O(2)(t) which allows one to observe both the fixed point solutions and also the presence of speeded oxygen kinetics following training. A method of plotting the eigenvalue versus oxygen demand is also used which allows one to observe where the maximum amplitude of the so-called slow component will be and also how training has changed the oxygen uptake kinetics by changing the strength of the attracting fixed point for a particular demand.

  15. Strain effect in epitaxial VO2 thin films grown on sapphire substrates using SnO2 buffer layers

    NASA Astrophysics Data System (ADS)

    Kim, Heungsoo; Bingham, Nicholas S.; Charipar, Nicholas A.; Piqué, Alberto

    2017-10-01

    Epitaxial VO2/SnO2 thin film heterostructures were deposited on m-cut sapphire substrates via pulsed laser deposition. By adjusting SnO2 (150 nm) growth conditions, we are able to control the interfacial strain between the VO2 film and SnO2 buffer layer such that the semiconductor-to-metal transition temperature (TC) of VO2 films can be tuned without diminishing the magnitude of the transition. It is shown that in-plane tensile strain and out-of-plane compressive strain of the VO2 film leads to a decrease of Tc. Interestingly, VO2 films on SnO2 buffer layers exhibit a structural phase transition from tetragonal-like VO2 to tetragonal-VO2 during the semiconductor-to-metal transition. These results suggest that the strain generated by SnO2 buffer provides an effective way for tuning the TC of VO2 films.

  16. Influence of V2O5 Content on the Gas-Based Direct Reduction of Hongge Vanadium Titanomagnetite Pellets with Simulated Shaft Furnace Gases

    NASA Astrophysics Data System (ADS)

    Li, Wei; Fu, Guiqin; Chu, Mansheng; Zhu, Miaoyong

    2018-01-01

    The influence of V2O5 content on the gas-based direct reduction of Hongge vanadium titanomagnetite pellets (HVTMP) was investigated with simulated shaft furnace gases, and the content levels were selected as 0 wt.%, 2 wt.%, 4 wt.%, and 6 wt.%, respectively. The results indicated that, with the increase of V2O5 content, the reduction was accelerated at an early stage due to the increase of the original porosity of the HVTMP. However, as the reduction proceeded, a slowing down in the reduction rate was observed, which was attributed to the formation of hardly reducible Fe2VO4. Major phases of reduced HVTMP were Fe2VO4, FeTiO3, and metallic iron. The morphology showed that the size of metallic iron particles of reduced HVTMP decreased with the increase of V2O5 content, V-bearing oxides embedded into the Ti-rich phases, and further reduction was restricted. This study not only established a relationship between the V2O5 content of HVTMP and its reduction behavior but could also contribute greatly to the effective utilization of Hongge vanadium titanomagnetite in shaft furnace.

  17. The single nucleotide polymorphism Gly482Ser in the PGC-1α gene impairs exercise-induced slow-twitch muscle fibre transformation in humans.

    PubMed

    Steinbacher, Peter; Feichtinger, René G; Kedenko, Lyudmyla; Kedenko, Igor; Reinhardt, Sandra; Schönauer, Anna-Lena; Leitner, Isabella; Sänger, Alexandra M; Stoiber, Walter; Kofler, Barbara; Förster, Holger; Paulweber, Bernhard; Ring-Dimitriou, Susanne

    2015-01-01

    PGC-1α (peroxisome proliferator-activated receptor γ co-activator 1α) is an important regulator of mitochondrial biogenesis and a master regulator of enzymes involved in oxidative phosphorylation. Recent evidence demonstrated that the Gly482Ser single nucleotide polymorphism (SNP) in the PGC-1α gene affects insulin sensitivity, blood lipid metabolism and binding to myocyte enhancer factor 2 (MEF2). Individuals carrying this SNP were shown to have a reduced cardiorespiratory fitness and a higher risk to develop type 2 diabetes. Here, we investigated the responses of untrained men with the Gly482Ser SNP to a 10 week programme of endurance training (cycling, 3 x 60 min/week, heart rate at 70-90% VO2peak). Quantitative data from analysis of biopsies from vastus lateralis muscle revealed that the SNP group, in contrast to the control group, lacked a training-induced increase in content of slow contracting oxidative fibres. Capillary supply, mitochondrial density, mitochondrial enzyme activities and intramyocellular lipid content increased similarly in both groups. These results indicate that the impaired binding of MEF2 to PGC-1α in humans with this SNP impedes exercise-induced fast-to-slow muscle fibre transformation.

  18. The Single Nucleotide Polymorphism Gly482Ser in the PGC-1α Gene Impairs Exercise-Induced Slow-Twitch Muscle Fibre Transformation in Humans

    PubMed Central

    Steinbacher, Peter; Feichtinger, René G.; Kedenko, Lyudmyla; Kedenko, Igor; Reinhardt, Sandra; Schönauer, Anna-Lena; Leitner, Isabella; Sänger, Alexandra M.; Stoiber, Walter; Kofler, Barbara; Förster, Holger; Paulweber, Bernhard; Ring-Dimitriou, Susanne

    2015-01-01

    PGC-1α (peroxisome proliferator-activated receptor γ co-activator 1α) is an important regulator of mitochondrial biogenesis and a master regulator of enzymes involved in oxidative phosphorylation. Recent evidence demonstrated that the Gly482Ser single nucleotide polymorphism (SNP) in the PGC-1α gene affects insulin sensitivity, blood lipid metabolism and binding to myocyte enhancer factor 2 (MEF2). Individuals carrying this SNP were shown to have a reduced cardiorespiratory fitness and a higher risk to develop type 2 diabetes. Here, we investigated the responses of untrained men with the Gly482Ser SNP to a 10 week programme of endurance training (cycling, 3 x 60 min/week, heart rate at 70-90% VO2peak). Quantitative data from analysis of biopsies from vastus lateralis muscle revealed that the SNP group, in contrast to the control group, lacked a training-induced increase in content of slow contracting oxidative fibres. Capillary supply, mitochondrial density, mitochondrial enzyme activities and intramyocellular lipid content increased similarly in both groups. These results indicate that the impaired binding of MEF2 to PGC-1α in humans with this SNP impedes exercise-induced fast-to-slow muscle fibre transformation. PMID:25886402

  19. Matching characteristics of different buffer layers with VO2 thin films

    NASA Astrophysics Data System (ADS)

    Yang, Kai; Zhang, Dongping; Liu, Yi; Guan, Tianrui; Qin, Xiaonan; Zhong, Aihua; Cai, Xingmin; Fan, Ping; Lv, Weizhong

    2016-10-01

    VO2 thin films were fabricated by reactive DC magnetron sputtering on different buffer layers of MgF2, Al2O3 and TiO2, respectively. The crystallinity and orientation relationship, thickness of VO2 thin films, atoms vibrational modes, optical and electrical property, surface morphology of films were characterized by X-ray diffraction, Raman scattering microscopy, step profiler, spectrophotometer, four-probe technique, and scanning electron microscopy, respectively. XRD results investigated that the films have preferential crystalline planes VO2 (011). The crystallinity of VO2 films grown on TiO2 buffer layers are superior to VO2 directly deposited on soda-lime glass. The Raman bands of the VO2 films correspond to an Ag symmetry mode of VO2 (M). The sample prepared on 100nm TiO2 buffer layer appears nanorods structure, and exhibits remarkable solar energy modulation ability as high as 5.82% in full spectrum and 23% in near infrared spectrum. Cross-sectional SEM image of the thin films samples indicate that MgF2 buffer layer has clear interface with VO2 layer. But there are serious interdiffusion phenomenons between Al2O3, TiO2 buffer layer with VO2 layer.

  20. Building a VO-compliant Radio Astronomical DAta Model for Single-dish radio telescopes (RADAMS)

    NASA Astrophysics Data System (ADS)

    Santander-Vela, Juan de Dios; García, Emilio; Leon, Stephane; Espigares, Victor; Ruiz, José Enrique; Verdes-Montenegro, Lourdes; Solano, Enrique

    2012-11-01

    The Virtual Observatory (VO) is becoming the de-facto standard for astronomical data publication. However, the number of radio astronomical archives is still low in general, and even lower is the number of radio astronomical data available through the VO. In order to facilitate the building of new radio astronomical archives, easing at the same time their interoperability with VO framework, we have developed a VO-compliant data model which provides interoperable data semantics for radio data. That model, which we call the Radio Astronomical DAta Model for Single-dish (RADAMS) has been built using standards of (and recommendations from) the International Virtual Observatory Alliance (IVOA). This article describes the RADAMS and its components, including archived entities and their relationships to VO metadata. We show that by using IVOA principles and concepts, the effort needed for both the development of the archives and their VO compatibility has been lowered, and the joint development of two radio astronomical archives have been possible. We plan to adapt RADAMS to be able to deal with interferometry data in the future.

  1. Significance of the velocity at VO2max and time to exhaustion at this velocity.

    PubMed

    Billat, L V; Koralsztein, J P

    1996-08-01

    In 1923, Hill and Lupton pointed out that for Hill himself, 'the rate of oxygen intake due to exercise increases as speed increases, reaching a maximum for the speeds beyond about 256 m/min. At this particular speed, for which no further increases in O2 intake can occur, the heart, lungs, circulation, and the diffusion of oxygen to the active muscle-fibres have attained their maximum activity. At higher speeds the requirement of the body for oxygen is far higher but cannot be satisfied, and the oxygen debt continuously increases'. In 1975, this minimal velocity which elicits maximal oxygen uptake (VO2max) was called 'critical speed' and was used to measure the maximal aerobic capacity (max Eox), i.e. the total oxygen consumed at VO2max. This should not be confused with the term 'critical power' which is closes to the power output at the 'lactate threshold'. In 1984, the term 'velocity at VO2max' and the abbreviation 'vVO2max' was introduced. It was reported that vVO2max is a useful variable that combines VO2max and economy into a single factor which can identify aerobic differences between various runners or categories of runners. vVO2max explained individual differences in performance that VO2max or running economy alone did not. Following that, the concept of a maximal aerobic running velocity (Vamax in m/sec) was formulated. This was a running velocity at which VO2max occurred and was calculated as the ratio between VO2max (ml/kg/min) minus oxygen consumption at rest, and the energy cost of running (ml/kg/sec). There are many ways to determine the velocity associated with VO2max making it difficult to compare maintenance times. In fact, the time to exhaustion (tlim) at vVO2max is reproducible in an individual, however, there is a great variability among individuals with a low coefficient of variation for vVO2max. For an average value of about 6 minutes, the coefficient of variation is about 25%. It seems that the lactate threshold which is correlated with the tlim at vVO2max can explain this difference among individuals, the role of the anaerobic contribution being significant. An inverse relationship has been found between tlim at vVO2max and VO2max, and a positive one between vVO2max and the velocity at the lactate threshold expressed as a fraction of vVO2max. These results are similar for different sports (e.g. running, cycling, kayaking, swimming). It seems that the real time spent at VO2max is significantly different from an exhaustive run at a velocity close to vVO2max (105% vVO2max). However, the minimal velocity which elicits VO2max, and the tlim at this velocity appear to convey valuable information when analysing a runner's performance over 1500m to a marathon.

  2. Thermal hysteresis measurement of the VO2 emissivity and its application in thermal rectification.

    PubMed

    Gomez-Heredia, C L; Ramirez-Rincon, J A; Ordonez-Miranda, J; Ares, O; Alvarado-Gil, J J; Champeaux, C; Dumas-Bouchiat, F; Ezzahri, Y; Joulain, K

    2018-05-31

    Hysteresis loops in the emissivity of VO 2 thin films grown on sapphire and silicon substrates by a pulsed laser deposition process are experimentally measured through the thermal-wave resonant cavity technique. Remarkable variations of about 43% are observed in the emissivity of both VO 2 films, within their insulator-to-metal and metal-to-insulator transitions. It is shown that: i) The principal hysteresis width (maximum slope) in the VO 2 emissivity of the VO 2  + silicon sample is around 3 times higher (lower) than the corresponding one of the VO 2  + sapphire sample. VO 2 synthesized on silicon thus exhibits a wider principal hysteresis loop with slower MIT than VO 2 on sapphire, as a result of the significant differences on the VO 2 film microstructures induced by the silicon or sapphire substrates. ii) The hysteresis width along with the rate of change of the VO 2 emissivity in a VO 2  + substrate sample can be tuned with its secondary hysteresis loop. iii) VO 2 samples can be used to build a radiative thermal diode able to operate with a rectification factor as high as 87%, when the temperature difference of its two terminals is around 17 °C. This record-breaking rectification constitutes the highest one reported in literature, for a relatively small temperature change of diode terminals.

  3. Validation of cardiac output using real-time measurement of oxygen consumption during cardiac catheterization in children under 3 years of age.

    PubMed

    Seckeler, Michael D; Hirsch, Russel; Beekman, Robert H; Goldstein, Bryan H

    2014-01-01

    To validate a method for determination of cardiac index (CI) using real-time measurement of oxygen consumption (VO2 ) in young children undergoing cardiac catheterization. Retrospective review comparing thermodilution cardiac index (TDCI) to CI calculated by the Fick equation using real-time measured VO2 (RT-VO2 ) and VO2 derived from 2 published predictive equations. Paired t-test and Bland-Altman analysis were used to compare TDCI to Fick CI. A survey to ascertain pediatric cardiac catheterization practices regarding VO2 determination was also conducted. Quaternary care children's hospital cardiac catheterization laboratory. Children <3 years old with structurally normal hearts undergoing cardiac catheterization under general anesthesia with at least one set of contemporaneous TDCI and RT-VO2 measurements. Thirty-six paired measurements of TDCI and RT-VO2 were made in 27 patients over a 2-year period. Indications for catheterization included congenital diaphragmatic hernia postrepair (n = 13), heart disease post-orthotopic heart transplant (n = 13), and suspected cardiomyopathy (n = 1). Mean age was 21.5 ± 8 months; median weight was 9.9 kg (IQR 8.57, 12.2). RT-VO2 was higher than VO2 predicted by the LaFarge equation (190 ± 31 vs. 173.8 ± 12.8 mL/min/m(2), P < .001), but there was no difference between TDCI and Fick CI calculated using VO2 from any method. Bland-Altman analysis showed excellent agreement between TDCI and Fick CI using RT-VO2 and VO2 predicted by the Lundell equation; Fick CI using VO2 predicted by the LaFarge equation showed fair agreement with TDCI. In children <3 years with a structurally normal heart, RT-VO2 generates highly accurate determinations of Fick CI as compared with TDCI. Additionally, in this population, VO2 derived from the LaFarge and Lundell equations generates accurate Fick CI compared with TDCI. Future studies are needed to identify factors associated with inaccurate VO2 generated from these predictive equations. © 2013 Wiley Periodicals, Inc.

  4. Enhanced Electrochemical Performance of Ultracentrifugation-Derived nc-Li3VO4/MWCNT Composites for Hybrid Supercapacitors.

    PubMed

    Iwama, Etsuro; Kawabata, Nozomi; Nishio, Nagare; Kisu, Kazuaki; Miyamoto, Junichi; Naoi, Wako; Rozier, Patrick; Simon, Patrice; Naoi, Katsuhiko

    2016-05-24

    Nanocrystalline Li3VO4 dispersed within multiwalled carbon nanotubes (MWCNTs) was prepared using an ultracentrifugation (uc) process and electrochemically characterized in Li-containing electrolyte. When charged and discharged down to 0.1 V vs Li, the material reached 330 mAh g(-1) (per composite) at an average voltage of about 1.0 V vs Li, with more than 50% capacity retention at a high current density of 20 A g(-1). This current corresponds to a nearly 500C rate (7.2 s) for a porous carbon electrode normally used in electric double-layer capacitor devices (1C = 40 mA g(-1) per activated carbon). The irreversible structure transformation during the first lithiation, assimilated as an activation process, was elucidated by careful investigation of in operando X-ray diffraction and X-ray absorption fine structure measurements. The activation process switches the reaction mechanism from a slow "two-phase" to a fast "solid-solution" in a limited voltage range (2.5-0.76 V vs Li), still keeping the capacity as high as 115 mAh g(-1) (per composite). The uc-Li3VO4 composite operated in this potential range after the activation process allows fast Li(+) intercalation/deintercalation with a small voltage hysteresis, leading to higher energy efficiency. It offers a promising alternative to replace high-rate Li4Ti5O12 electrodes in hybrid supercapacitor applications.

  5. Highly infrared sensitive VO2 nanowires for a nano-optical device.

    PubMed

    Bhuyan, Prabal Dev; Gupta, Sanjeev K; Kumar, Ashok; Sonvane, Yogesh; Gajjar, P N

    2018-04-25

    Recent studies on the electronic, magnetic and optical properties of VO2 (vanadium dioxide) materials have motivated the exploration of one dimensional VO2 nanowires. First principles calculations were performed to investigate the structural, electronic, magnetic and optical properties of the monoclinic (M) and rutile (R) phases of VO2 nanowires. The monoclinic phase shows semiconducting behaviour with a band gap of 1.17 eV, whereas the rutile phase of VO2 nanowires behaves as a spin gapless semiconducting material, as band lines cross the Fermi level due only to up spin contribution. The monoclinic structure of VO2 nanowires is found to be paramagnetic and the rutile structure shows ferromagnetic half metal behavior. The conductivity calculation for VO2 nanowires shows the metal-insulator transition (MIT) temperature to be 250 K. The possible mechanism of VO2 nanowires to be used as smart windows has been discussed, as the nanowires are highly sensitive in the infrared (IR) region. Interestingly, at low temperature, the VO2 monoclinic structure allows infrared light to be transmitted, while VO2 with the rutile phase blocks light in the IR region. Furthermore, we adsorbed CO2, N2 and SO2 gas molecules on 1D VO2 monoclinic nanowire to investigate their interaction behaviour. It was observed that the absorption and transmission properties of VO2 dramatically change upon the adsorption of CO2 and SO2 gas molecules, which is likely to open up its application as an optical gas sensor.

  6. Estimating cardiorespiratory fitness in well-functioning older adults: treadmill validation of the long distance corridor walk.

    PubMed

    Simonsick, Eleanor M; Fan, Ellen; Fleg, Jerome L

    2006-01-01

    To determine criterion validity of the 400-m walk component of the Long Distance Corridor Walk (LDCW) and develop equations for estimating peak oxygen consumption (VO2) from 400-m time and factors intrinsic to test performance (e.g., heart rate (HR) and systolic blood pressure (SBP) response) in older adults. Cross-sectional validation study. Gerontology Research Center, National Institute on Aging, Baltimore, Maryland. Healthy volunteers (56 men and 46 women) aged 60 to 91 participating in the Baltimore Longitudinal Study of Aging between August 1999 and July 2000. The LDCW, consisting of a 2-minute walk followed immediately by a 400-m walk "done as quickly as possible" over a 20-m course was administered the day after maximal treadmill testing. HR and SBP were measured before testing and at the end of the 400-m walk. Weight, height, activity level, perceived effort, and stride length were also acquired. Peak VO2 ranged from 12.2 to 31.1 mL oxygen/kg per minute, and 400-m time ranged from 2 minutes 52 seconds to 6 minutes 18 seconds. Correlation between 400-m time and peak VO2 was -0.79. The estimating equation from linear regression included 400-m time (partial coefficient of determination (R2)=0.625), long versus short stride (partial R2=0.090), ending SBP (partial R2=0.019), and a correction factor for fast 400-m time (<240 seconds; partial R2=0.020) and explained 75.5% of the variance in peak VO2 (correlation coefficient=0.87). A 400-m walk performed as part of the LDCW provides a valid estimate of peak VO2 in older adults. Incorporating low-cost, safe assessments of fitness in clinical and research settings can identify early evidence of physical decline and individuals who may benefit from therapeutic interventions.

  7. VO2 attained during treadmill running: the influence of a specialist (400-m or 800-m) event.

    PubMed

    James, David V B; Sandals, Leigh E; Draper, Stephen B; Maldonado-Martin, Sara; Wood, Dan M

    2007-06-01

    Previously it has been observed that, in well-trained 800-m athletes, VO2max is not attained during middle-distance running events on a treadmill, even when a race-type pacing strategy is adopted. Therefore, the authors investigated whether specialization in a particular running distance (400-m or 800-m) influences the VO2 attained during running on a treadmill. Six 400-m and six 800-m running specialists participated in the study.A 400-m trial and a progressive test to determine VO2max were completed in a counterbalanced order. Oxygen uptakes attained during the 400-m trial were compared to examine the influence of specialist event. A VO2 plateau was observed in all participants for the progressive test, demonstrating the attainment of VO2max. The VO2max values were 56.2 +/- 4.7 and 69.3 +/- 4.5 mL x kg-1 x min-1 for the 400-m- and 800-m-event specialists, respectively (P = .0003). Durations for the 400-m trial were 55.1 +/- 4.2 s and 55.8 +/- 2.3 s for the 400-m- and 800-m-event specialists, respectively. The VO2 responses achieved were 93.1% +/- 2.0% and 85.7% +/- 3.0% VO2max for the 400-m- and 800-m-event specialists, respectively (P = .001). These results demonstrate that specialist running events do appear to influence the percentage of VO2max achieved in the 400-m trial, with the 800-m specialists attaining a lower percentage of VO2max than the 400-m specialists. The 400-m specialists appear to compensate for a lower VO2max by attaining a higher percentage VO2max during a 400-m trial.

  8. Applied physiology of marathon running.

    PubMed

    Sjödin, B; Svedenhag, J

    1985-01-01

    Performance in marathon running is influenced by a variety of factors, most of which are of a physiological nature. Accordingly, the marathon runner must rely to a large extent on a high aerobic capacity. But great variations in maximal oxygen uptake (VO2 max) have been observed among runners with a similar performance capacity, indicating complementary factors are of importance for performance. The oxygen cost of running or the running economy (expressed, e.g. as VO2 15 at 15 km/h) as well as the fractional utilisation of VO2 max at marathon race pace (%VO2 Ma X VO2 max-1) [where Ma = mean marathon velocity] are additional factors which are known to affect the performance capacity. Together VO2 max, VO2 15 and %VO2 Ma X VO2 max-1 can almost entirely explain the variation in marathon performance. To a similar degree, these variables have also been found to explain the variations in the 'anaerobic threshold'. This factor, which is closely related to the metabolic response to increasing exercise intensities, is the single variable that has the highest predictive power for marathon performance. But a major limiting factor to marathon performance is probably the choice of fuels for the exercising muscles, which factor is related to the %VO2 Ma X VO2 max-1. Present indications are that marathon runners, compared with normal individuals, have a higher turnover rate in fat metabolism at given high exercise intensities expressed both in absolute (m/sec) and relative (%VO2 max) terms. The selection of fat for oxidation by the muscles is important since the stores of the most efficient fuel, the carbohydrates, are limited. The large amount of endurance training done by marathon runners is probably responsible for similar metabolic adaptations, which contribute to a delayed onset of fatigue and raise the VO2 Ma X VO2max-1. There is probably an upper limit in training kilometrage above which there are no improvements in the fractional utilisation of VO2 max at the marathon race pace. The influence of training on VO2 max and, to some extent, on the running economy appears, however, to be limited by genetic factors.

  9. The Role of Peroxisome Proliferator-Activated Receptors and Their Transcriptional Coactivators Gene Variations in Human Trainability: A Systematic Review

    PubMed Central

    Petr, Miroslav; Zajac, Adam; Maciejewska-Skrendo, Agnieszka

    2018-01-01

    Background: The peroxisome proliferator-activated receptors (PPARA, PPARG, PPARD) and their transcriptional coactivators’ (PPARGC1A, PPARGC1B) gene polymorphisms have been associated with muscle morphology, oxygen uptake, power output and endurance performance. The purpose of this review is to determine whether the PPARs and/or their coactivators’ polymorphisms can predict the training response to specific training stimuli. Methods: In accordance with the Preferred Reporting Items for Systematic Reviews and Meta Analyses, a literature review has been run for a combination of PPARs and physical activity key words. Results: All ten of the included studies were performed using aerobic training in general, sedentary or elderly populations from 21 to 75 years of age. The non-responders for aerobic training (VO2peak increase, slow muscle fiber increase and low-density lipoprotein decrease) are the carriers of PPARGC1A rs8192678 Ser/Ser. The negative responders for aerobic training (decrease in VO2peak) are carriers of the PPARD rs2267668 G allele. The negative responders for aerobic training (decreased glucose tolerance and insulin response) are subjects with the PPARG rs1801282 Pro/Pro genotype. The best responders to aerobic training are PPARGC1A rs8192678 Gly/Gly, PPARD rs1053049 TT, PPARD rs2267668 AA and PPARG rs1801282 Ala carriers. Conclusions: The human response for aerobic training is significantly influenced by PPARs’ gene polymorphism and their coactivators, where aerobic training can negatively influence glucose metabolism and VO2peak in some genetically-predisposed individuals. PMID:29762540

  10. Metamaterials based on the phase transition of VO2

    NASA Astrophysics Data System (ADS)

    Liu, Hongwei; Lu, Junpeng; Renshaw Wang, Xiao

    2018-01-01

    In this article, we present a comprehensive review on recent research progress in design and fabrication of active tunable metamaterials and devices based on phase transition of VO2. Firstly, we introduce mechanisms of the metal-to-insulator phase transition (MIPT) in VO2 investigated by ultrafast THz spectroscopies. By analyzing the THz spectra, the evolutions of MIPT in VO2 induced by different external excitations are described. The superiorities of using VO2 as building blocks to construct highly tunable metamaterials are discussed. Subsequently, the recently demonstrated metamaterial devices based on VO2 are reviewed. These metamaterials devices are summarized and described in the categories of working frequency. In each working frequency range, representative metamaterials based on VO2 with different architectures and functionalities are reviewed and the contributions of the MIPT of VO2 are emphasized. Finally, we conclude the recent reports and provide a prospect on the strategies of developing future tunable metamaterials based on VO2.

  11. Voltage-induced switching dynamics based on an AZO/VO2/AZO sandwiched structure

    NASA Astrophysics Data System (ADS)

    Xiao, Han; Li, Yi; Fang, Baoying; Wang, Xiaohua; Liu, Zhimin; Zhang, Jiao; Li, Zhengpeng; Huang, Yaqin; Pei, Jiangheng

    2017-11-01

    A vanadium dioxide (VO2) thin film was prepared on an Al-doped ZnO (AZO) conductive glass substrate by DC magnetron sputtering and a post-annealing process. The AZO/VO2/AZO sandwiched structure was fabricated on the VO2/AZO composite film using photolithography and a chemical etching process. The composition, microstructure and optical properties of the VO2/AZO composite film were tested. The results showed that the VO2/AZO composite film was poly-crystalline and the AZO layer did not change the preferred growth orientation of VO2. When the voltage was applied on both of the transparent conductive layers of the AZO/VO2/AZO sandwiched structure, an abrupt change in the current was observed at different temperatures. The temperature dependence of I-V characteristic curves for the AZO/VO2/AZO sandwiched structure was analyzed. The phase transition voltage value is 7.5 V at 20 °C and decreases with increasing temperature.

  12. Flexible thermochromic window based on hybridized VO2/graphene.

    PubMed

    Kim, Hyeongkeun; Kim, Yena; Kim, Keun Soo; Jeong, Hu Young; Jang, A-Rang; Han, Seung Ho; Yoon, Dae Ho; Suh, Kwang S; Shin, Hyeon Suk; Kim, TaeYoung; Yang, Woo Seok

    2013-07-23

    Large-scale integration of vanadium dioxide (VO2) on mechanically flexible substrates is critical to the realization of flexible smart window films that can respond to environmental temperatures to modulate light transmittance. Until now, the formation of highly crystalline and stoichiometric VO2 on flexible substrate has not been demonstrated due to the high-temperature condition for VO2 growth. Here, we demonstrate a VO2-based thermochromic film with unprecedented mechanical flexibility by employing graphene as a versatile platform for VO2. The graphene effectively functions as an atomically thin, flexible, yet robust support which enables the formation of stoichiometric VO2 crystals with temperature-driven phase transition characteristics. The graphene-supported VO2 was capable of being transferred to a plastic substrate, forming a new type of flexible thermochromic film. The flexible VO2 films were then integrated into the mock-up house, exhibiting its efficient operation to reduce the in-house temperature under infrared irradiation. These results provide important progress for the fabrication of flexible thermochromic films for energy-saving windows.

  13. Vanadium and cancer treatment: antitumoral mechanisms of three oxidovanadium(IV) complexes on a human osteosarcoma cell line.

    PubMed

    León, I E; Butenko, N; Di Virgilio, A L; Muglia, C I; Baran, E J; Cavaco, I; Etcheverry, S B

    2014-05-01

    We report herein the antitumor actions of three oxidovanadium(IV) complexes on MG-63 human osteosarcoma cell line. The three complexes: VO(oda), VO(oda)bipy and VO(oda)phen (oda=oxodiacetate), caused a concentration dependent inhibition of cell viability. The antiproliferative action of VO(oda)phen could be observed in the whole range of concentrations (at 2.5 μM), while VO(oda)bipy and VO(oda) showed a decrease of cell viability only at higher concentrations (at 50 and 75 μM, respectively) (p<0.01). Moreover, VO(oda)phen caused a decrease of lysosomal and mitochondrial activities at 2.5 μM, while VO(oda) and VO(oda)bipy affected neutral red uptake and mitochondrial metabolism at 50 μM (p<0.01). On the other hand, no DNA damage studied by the Comet assay could be observed in MG-63 cells treated with VO(oda) at 2.5-10 μM. Nevertheless, VO(oda)phen and VO(oda)bipy induced DNA damage at 2.5 and 10 μM, respectively (p<0.01). The generation of reactive oxygen species increased at 10 μM of VO(oda)phen and only at 100 μM of VO(oda) and VO(oda)bipy (p<0.01). Besides, VO(oda)phen and VO(oda)bipy triggered apoptosis as determined by externalization of the phosphatidylserine. The determination of DNA cleavage by agarose gel electrophoresis showed that the ability of VO(oda)(bipy) is similar to that of VO(oda), while VO(oda)(phen) showed the highest nuclease activity in this series. Overall, our results showed a good relationship between the bioactivity of the complexes and their structures since VO(oda)phen presented the most potent antitumor action in human osteosarcoma cells followed by VO(oda)bipy and then by VO(oda) according to the number of intercalating heterocyclic moieties. © 2013.

  14. Business Technology Curriculum Guide. Vo. Ed. 270. Revised 2/94.

    ERIC Educational Resources Information Center

    Idaho State Div. of Vocational Education, Boise.

    This guide, which combines business and marketing concepts with microcomputer applications, is intended to be used in designing a 2-semester course in business technology and to serve as the main component for articulation activities in the event that students completing the course decide to pursue additional training or education. The course…

  15. Anisotropic vanadium dioxide sculptured thin films with superior thermochromic properties.

    PubMed

    Sun, Yaoming; Xiao, Xiudi; Xu, Gang; Dong, Guoping; Chai, Guanqi; Zhang, Hua; Liu, Pengyi; Zhu, Hanmin; Zhan, Yongjun

    2013-09-25

    VO2 (M) STF through reduction of V2O5 STF was prepared. The results illustrate that V2O5 STF can be successfully obtained by oblique angle thermal evaporation technique. After annealing at 550 °C/3 min, the V2O5 STF deposited at 85° can be easily transformed into VO2 STF with slanted columnar structure and superior thermochromic properties. After deposition SiO2 antireflective layer, Tlum of VO2 STF is enhanced 26% and ΔTsol increases 60% compared with that of normal VO2 thin films. Due to the anisotropic microstructure of VO2 STF, angular selectivity transmission of VO2 STF is observed and the solar modulation ability is further improved from 7.2% to 8.7% when light is along columnar direction. Moreover, the phase transition temperature of VO2 STF can be depressed into 54.5 °C without doping. Considering the oblique incidence of sunlight on windows, VO2 STF is more beneficial for practical application as smart windows compared with normal homogenous VO2 thin films.

  16. Anisotropic vanadium dioxide sculptured thin films with superior thermochromic properties

    PubMed Central

    Sun, Yaoming; Xiao, Xiudi; Xu, Gang; Dong, Guoping; Chai, Guanqi; Zhang, Hua; Liu, Pengyi; Zhu, Hanmin; Zhan, Yongjun

    2013-01-01

    VO2 (M) STF through reduction of V2O5 STF was prepared. The results illustrate that V2O5 STF can be successfully obtained by oblique angle thermal evaporation technique. After annealing at 550°C/3 min, the V2O5 STF deposited at 85° can be easily transformed into VO2 STF with slanted columnar structure and superior thermochromic properties. After deposition SiO2 antireflective layer, Tlum of VO2 STF is enhanced 26% and ΔTsol increases 60% compared with that of normal VO2 thin films. Due to the anisotropic microstructure of VO2 STF, angular selectivity transmission of VO2 STF is observed and the solar modulation ability is further improved from 7.2% to 8.7% when light is along columnar direction. Moreover, the phase transition temperature of VO2 STF can be depressed into 54.5°C without doping. Considering the oblique incidence of sunlight on windows, VO2 STF is more beneficial for practical application as smart windows compared with normal homogenous VO2 thin films. PMID:24067743

  17. Characterization of nanostructured VO2 thin films grown by magnetron controlled sputtering deposition and post annealing method.

    PubMed

    Chen, Sihai; Lai, Jianjun; Dai, Jun; Ma, Hong; Wang, Hongchen; Yi, Xinjian

    2009-12-21

    By magnetron controlled sputtering system, a new nanostructured metastable monoclinic phase VO2 (B) thin film has been fabricated. The testing result shows that this nanostructured VO2 (B) thin film has high temperature coefficient of resistance (TCR) of -7%/K. Scanning electron microscopy measurement shows that the average grain diameter of the VO2 (B) crystallite is between 100 and 250 nm. After post annealed, VO2 (B) crystallite is changed into monoclinic (M) phase VO2 (M) crystallite with the average grain diameter between 20 and 50 nm. A set up of testing the thin film switching time is established. The test result shows the switching time is about 50 ms. With the nanostructured VO2 (B) and VO2 (M) thin films, optical switches and high sensitivity detectors will be presented.

  18. Multiple variables explain the variability in the decrement in VO2max during acute hypobaric hypoxia.

    PubMed

    Robergs, R A; Quintana, R; Parker, D L; Frankel, C C

    1998-06-01

    We used multiple regression analyses to determine the relationships between the decrement in sea level (SL, 760 Torr) VO2max during hypobaric hypoxia (HH) and variables that could alter or be related to the decrement in VO2max. HH conditions consisted of 682 Torr, 632 Torr, and 566 Torr, and the measured independent variables were SL-VO2max, SL lactate threshold (SL-LT), the change in hemoglobin saturation at VO2max between 760 and 566 Torr (delta SaO2max), lean body mass (LBM), and gender. Male (N = 14) and female (N = 14) subjects of varied fitness, training status, and residential altitude (1,640-2,460 m) completed cycle ergometry tests of VO2max at each HH condition under randomized and single-blinded conditions. VO2max decreased significantly from 760 Torr after 682 Torr (approximately 915 m) (3.5 +/- 0.9 to 3.4 +/- 0.8 L.min-1, P = 0.0003). Across all HH conditions, the slope of the relative decrement in VO2max (%VO2max) during HH was -9.2%/100 mm Hg (-8.1%/1000 m) with an initial decrease from 100% estimated to occur below 705 Torr (610 m). Step-wise multiple regression revealed that SL-VO2max, SL-LT, delta SaO2max, LBM, and gender each significantly combined to account for 89.03% of the variance in the decrement in VO2max (760-566 Torr) (P < 0.001). Individuals who have a combination of a large SL-VO2max, a small SL-LT (VO2, L.min-1), greater reductions in delta SaO2max, a large LBM, and are male have the greatest decrement in VO2max during HH. The unique variance explanation afforded by SL-LT, LBM, and gender suggests that issues pertaining to oxygen diffusion within skeletal muscle may add to the explanation of between subjects variability in the decrement in VO2max during HH.

  19. Cardiovascular responses to a high-volume continuous circuit resistance training protocol.

    PubMed

    Gotshalk, Lincoln A; Berger, Richard A; Kraemer, William J

    2004-11-01

    The purpose of this investigation was to determine the level of cardiovascular stress elicited by continuous and prolonged circuit resistance training (CRT). Each of the 11 men who volunteered as a subject were tested to determine oxygen consumption and heart rate responses to a submaximal and maximal treadmill protocol and a CRT session consisting of 10 exercises and 10 repetitions at 40% of 1 repetition maximum (1RM) for each station with 4.6 circuits performed. The physiological stress of the CRT in this study was evident by the sustained heart rate of more than 70% of maximum for 16.6 minutes, with the last 12 minutes at more than 80%. Despite the large anaerobic component in CRT, Vo(2) was sustained at 50% or more of maximum for the final 12 minutes. Treadmill running, involving large muscle groups, increased Vo(2) more rapidly than CRT, where alternating larger and smaller muscle groups were used. In addition, at the same Vo(2) heart rate differed significantly between the 2 modes of activity. Heart rate in CRT was higher (at 165) than the heart rate of 150 found during treadmill running at the same 50% Vo(2). Such workouts may be used in a training cycle in classical linear periodization or in a nonlinear program day targeting local muscular endurance under intense cardiorespiratory conditions, which may help individuals develop enhanced toleration of physiological environments where high cardiovascular demands and higher lactate concentrations are present.

  20. Investigation of electron beam lithography effects on metal-insulator transition behavior of vanadium dioxide

    NASA Astrophysics Data System (ADS)

    Yuce, H.; Alaboz, H.; Demirhan, Y.; Ozdemir, M.; Ozyuzer, L.; Aygun, G.

    2017-11-01

    Vanadium dioxide (VO2) shows metal-insulator phase transition at nearly 68 °C. This metal-insulator transition (MIT) in VO2 leads to a significant change in near-infrared transmittance and an abrupt change in the resistivity of VO2. Due to these characteristics, VO2 plays an important role on optic and electronic devices, such as thermochromic windows, meta-materials with tunable frequency, uncooled bolometers and switching devices. In this work, VO2 thin films were fabricated by reactive direct current magnetron sputtering in O2/Ar atmosphere on sapphire substrates without any further post annealing processes. The effect of sputtering parameters on optical characteristics and structural properties of grown thin films was investigated by SEM, XRD, Raman and UV/VIS spectrophotometer measurements. Patterning process of VO2 thin films was realized by e-beam lithography technique to monitor the temperature dependent electrical characterization. Electrical properties of VO2 samples were characterized using microprobe station in a vacuum system. MIT with hysteresis behavior was observed for the unpatterned square samples at around 68 °C. By four orders of magnitude of resistivity change was measured for the deposited VO2 thin films at transition temperature. After e-beam lithography process, substantial results in patterned VO2 thin films were observed. In this stage, for patterned VO2 thin films as stripes, the change in resistivity of VO2 was reduced by a factor of 10. As a consequence of electrical resistivity measurements, MIT temperature was shifted from 68 °C to 50 °C. The influence of e-beam process on the properties of VO2 thin films and the mechanism of the effects are discussed. The presented results contribute to the achievement of VO2 based thermochromic windows and bolometer applications.

  1. High-intensity Interval Training in Different Exercise Modes: Lessons from Time to Exhaustion.

    PubMed

    Sousa, Ana Catarina; Fernandes, Ricardo J; Boas, Joao Paulo Vilas; Figueiredo, Pedro

    2018-06-20

    To provide information for high-intensity interval training (HIIT) load, we compared the temporal variables of VO 2 response at, and after, a time sustained at the exercise intensity corresponding to VO 2max (Tlim) in different exercise modes. Forty-five trained male swimmers (11), rowers (13), runners (10) and cyclists (11) completed an incremental protocol to determine the velocity (vVO 2max ) or power (wVO 2max ) at VO 2max and a square wave exercise from rest to 100% of vVO 2max /wVO 2max . The temporal variables of VO 2 response were examined using a breath-by-breath gas analyzer. VO 2 responses were not different between exercise modes, except for the percentage of VO 2max at 50% of Tlim, which was ~6% higher in rowing compared to cycling (97.70±2.90 vs 92.40±5.69%, p =0.013). During the recovery period, both swimmers and rowers evidenced higher percentages of VO 2max compared to cyclists at 30 s (65.1±10.4 and 65.7±5.6 vs 52.7±5.6%) and 60 s (41.7±10.8 and 38.4±5.4 vs 30.4±1.8%) time periods, all for p< 0.01. Furthermore, swimmers presented higher time values to reach 50% VO 2max compared to runners and cyclists (51.1±15.6 vs 38.1±6.7 and 33.8±4.7%; p <0.001). When training at 100% of VO 2max intensity, fixed intervals for HIIT could be set freely. However, recovery periods based on time or intensity are exercise-mode dependent. © Georg Thieme Verlag KG Stuttgart · New York.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guo, Peijun; Weimer, Matthew S.; Emery, Jonathan D.

    Actively tunable optical transmission through artificial metamaterials holds great promise for next-generation nanophotonic devices and metasurfaces. Plasmonic nanostructures and phase change materials have been extensively studied to this end due to their respective strong interactions with light and tunable dielectric constants under external stimuli. Seamlessly integrating plasmonic components with phase change materials, as demonstrated in the present work, can facilitate phase change by plasmonically enabled light confinement and meanwhile make use of the high sensitivity of plasmon resonances to the variation of dielectric constant associated with the phase change. The hybrid platform here is composed of plasmonic indium tin-oxide nanorodmore » arrays (ITO-NRAs) conformally coated with an ultrathin layer of a prototypical phase change material, vanadium dioxide (VO2), which enables all-optical modulation of the infrared as well as the visible spectral ranges. The interplay between the intrinsic plasmonic nonlinearity of ITO-NRAs and the phase transition induced permittivity change of VO2 gives rise to spectral and temporal responses that cannot be achieved with individual material components alone.« less

  3. Improving the electrocatalytic performance of carbon nanotubes for VO2+/VO2+ redox reaction by KOH activation

    NASA Astrophysics Data System (ADS)

    Dai, Lei; Jiang, Yingqiao; Meng, Wei; Zhou, Huizhu; Wang, Ling; He, Zhangxing

    2017-04-01

    In this paper, carbon nanotubes (CNTs) was activated by KOH treatment at high temperature and investigated as catalyst for VO2+/VO2+ redox reaction for vanadium redox flow battery (VRFB). X-ray photoelectron spectroscopy results suggest that the oxygen-containing groups can be introduced on CNTs by KOH activation. The mass transfer of vanadium ions can be accelerated by chemical etching by KOH activation and improved wettability due to the introduction of hydrophilic groups. The electrochemical properties of VO2+/VO2+ redox reaction can be enhanced by introduced oxygen-containing groups as active sites. The sample treated at 900 °C with KOH/CNTs mass ratio of 3:1 (CNTs-3) exhibits the highest electrocatalytic activity for VO2+/VO2+ redox reaction. The cell using CNTs-3 as positive catalyst demonstrates the smallest electrochemical polarization, the highest capacity and efficiency among the samples. Using KOH-activated CNTs-3 can increase the average energy efficiency of the cell by 4.4%. This work suggests that KOH-activated CNTs is a low-cost, efficient and promising catalyst for VO2+/VO2+ redox reaction for VRFB system.

  4. Electrochemical Synthesis of Amorphous VO2 Colloids and Their Rapid Thermal Transforming to VO2 (M) Nanoparticles with Good Thermochromic Performance.

    PubMed

    Wu, Hao; Li, Ming; Zhong, Li; Luo, Yuan Yuan; Li, Guang Hai

    2016-12-05

    Amorphous VO 2 (a-VO 2 ) colloids were synthesized by electrochemical anodic oxidation of metallic vanadium. It was found that the a-VO 2 colloids have a cotton-like morphology composed of very small clusters, and that the crystallization temperature of the a-VO 2 colloids can be adjusted either by the electrolyte of the anodic oxidation or/and the dispersion agent of the colloids. VO 2 (M) nanoparticles (NPs) (and a NP film) with an average size of about 50 nm can be obtained by a rapid thermal annealing of the a-VO 2 colloids at 310 °C under air, which is beneficial for practical applications. The VO 2 (M) NP film shows an obvious metal-semiconductor transition with a resistance less than 10 Ω in the metallic state. An integral visible transmittance of 40.7 %, a solar transmittance modulation of 9.4 %, and a resistance modulation in the order of 5×10 4 were realized in the VO 2 (M) NP film. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Normalization for peak oxygen uptake increases the prognostic power of the ventilatory response to exercise in patients with chronic heart failure.

    PubMed

    Guazzi, Marco; De Vita, Stefano; Cardano, Paola; Barlera, Simona; Guazzi, Maurizio D

    2003-09-01

    Peak exercise oxygen uptake (peak VO2) and ventilation to CO2 production (VE/VCO2) slope are established prognostic indicators in patients with chronic heart failure (CHF). A high VE/VCO2 slope, however, does not take into account the level of physical performance as expressed by peak VO2. We hypothesized that the prognostic value of a high VE/VCO2 slope may be improved by normalization for peak VO2 (VE/VCO2/VO2). One hundred patients with CHF underwent pulmonary function tests at rest (spirometry and lung diffusion capacity) and maximal cardiopulmonary exercise testing. The prognostic value of VE/VCO2 slope, peak VO2 and VE/VCO2/VO2 was probed prospectively. Twenty-one patients died from cardiac reasons during a mean follow-up of 26 +/- 19 months. Nonsurvivors, compared to survivors, showed a lower peak VO2 (13.6 +/- 4.0 vs 17.5 +/- 4.1 mL x min(-1) x kg(-1), P <.01) and a steeper VE/VCO2 slope (43 +/- 11 vs 31.6 +/- 5.0, P <.01). Nonetheless, in patients whose VE/VCO2 slope exceeded 34 (upper normal limit), there was no correlation with peak VO2 (r = -35, P = not significant). Interestingly 35% of them showed a normal exercise performance (peak VO2 > or =18 mL x min(-1) x kg(-1)). At multivariate analysis, the VE/VCO2 slope showed a prognostic power stronger than that of peak VO2; however, the VE/VCO2/VO2 index retained a prognostic power greater than that of both VE/VCO2 slope and peak VO2. A VE/VCO2/VO2 > or =2.4 signaled cases at higher risk. Discrepancies between VE/VCO2 slope and peak VO2 may generate uncertainty. Normalization of the former by the latter improves outcome prediction and may be considered a simple and effective way for maximizing the clinical applicability of these 2 indicators.

  6. Li2.97Mg0.03VO4: High rate capability and cyclability performances anode material for rechargeable Li-ion batteries

    NASA Astrophysics Data System (ADS)

    Dong, Youzhong; Zhao, Yanming; Duan, He; Singh, Preetam; Kuang, Quan; Peng, Hongjian

    2016-07-01

    Mg-doped composite, Li2.97Mg0.03VO4, with an orthorhombic structure was prepared by a sol-gel method. The effects of the Mg doping on the structure and electrochemical performance of Li3VO4 were investigated. The X-ray diffraction pattern shows that the Mg doping does not change the crystal structure of Li3VO4. The EDS mappings indicated the fairly uniform distribution of Mg throughout the grains of Li2.97Mg0.03VO4. Electronic conductivity of Mg-doped Li3VO4 increased by two orders of magnitude compared to that of pure Li3VO4. CV and EIS measurement confirms that the Li2.97Mg0.03VO4 sample exhibits a smaller polarization and transfer resistance and a higher lithium diffusion coefficient compared with the pure Li3VO4. Due to the better electrochemical kinetics properties, Mg-doped Li3VO4 showed a significant improved performance compared to the pure Li3VO4, especially for the high rate capability. At the higher discharge/charge rate (2C), the discharge and charge capacities of 415.5 and 406.1 mAh/g have been obtained for the Li2.97Mg0.03VO4 which is more than three times higher the discharge/charge capacities of Li3VO4. The discharge and charge capacities of pure Li3VO4 are only 126.4 and 125.8 mAh/g respectively. The excellent electrochemical performance of Li2.97Mg0.03VO4 enables it as a promising anode material for rechargeable lithium-ion batteries.

  7. Reactions of vanadium dioxide molecules with acetylene: infrared spectra of VO2(η(2)-C2H2)(x) (x = 1, 2) and OV(OH)CCH in solid neon.

    PubMed

    Zhou, Xiaojie; Chen, Mohua; Zhou, Mingfei

    2013-07-03

    Reactions of vanadium dioxide molecules with acetylene have been studied by matrix isolation infrared spectroscopy. Reaction intermediates and products are identified on the basis of isotopic substitutions as well as density functional frequency calculations. Ground state vanadium dioxide molecule reacts with acetylene in forming the side-on-bonded VO2(η(2)-C2H2) and VO2(η(2)-C2H2)2 complexes spontaneously on annealing in solid neon. The VO2(η(2)-C2H2) complex is characterized to have a (2)B2 ground state with C2v symmetry, whereas the VO2(η(2)-C2H2)2 complex has a (2)A ground state with C2 symmetry. The VO2(η(2)-C2H2) and VO2(η(2)-C2H2)2 complexes are photosensitive. The VO2(η(2)-C2H2) complex rearranges to the OV(OH)CCH molecule upon UV-vis light excitation.

  8. F-doped VO2 nanoparticles for thermochromic energy-saving foils with modified color and enhanced solar-heat shielding ability.

    PubMed

    Dai, Lei; Chen, Shi; Liu, Jianjun; Gao, Yanfeng; Zhou, Jiadong; Chen, Zhang; Cao, Chuanxiang; Luo, Hongjie; Kanehira, Minoru

    2013-07-28

    F-doped VO2 (M1) nanoparticles were prepared via one-pot hydrothermal synthesis. The F-doping can minimise the size of the VO2 (M1) nanoparticles, induce a homogeneous size distribution and effectively decrease the phase transition temperature to 35 °C at 2.93% F in VO2. VO2 smart glass foils obtained by casting these nanoparticles exhibit excellent thermochromism in the near-infrared region, which suggests that these foils can be used for energy-efficient glass. Compared to a pure VO2 foil, the 2.93% F-doped VO2 foil exhibits an increased solar-heat shielding ability (35.1%) and a modified comfortable colour, while still retaining an excellent solar modulation ability (10.7%) and an appropriate visible transmittance (48.7%). The F-doped VO2 foils are the first to simultaneously meet the requirements of a reduced phase transition temperature, diluted colour and excellent thermochromic properties, and these properties make the further improved F-doped VO2 foils suitable for commercial applications in energy efficient glass.

  9. Effects of V2O3 buffer layers on sputtered VO2 smart windows: Improved thermochromic properties, tunable width of hysteresis loops and enhanced durability

    NASA Astrophysics Data System (ADS)

    Long, Shiwei; Cao, Xun; Sun, Guangyao; Li, Ning; Chang, Tianci; Shao, Zewei; Jin, Ping

    2018-05-01

    Vanadium dioxide (VO2) is one of the most well-known thermochromic materials, which exhibits a notable optical change from transparent to reflecting in the infrared region upon a metal-insulator phase transition. For practical applications, VO2 thin films should be in high crystalline quality to obtain a strong solar modulation ability (ΔTsol). Meanwhile, narrow hysteresis loops and robust ambient durability are also indispensable for sensitivity and long-lived utilization, respectively. In this work, a series of high-quality V2O3/VO2 bilayer structures were grown on quartz glass substrates by reactive magnetron sputtering. Basically, the bottom V2O3 acts as the buffer layer to improve the crystallinity of the top VO2, while the VO2 serves as the thermochromic layer to guarantee the solar modulation ability for energy-saving. We observed an obvious increase in ΔTsol of 76% (from 7.5% to 13.2%) for VO2 films after introducing V2O3 buffer layers. Simultaneously, a remarkable reduction by 79% (from 21.9 °C to 4.7 °C) in width of hysteresis loop was obtained when embedding 60 nm V2O3 buffer for 60 nm VO2. In addition, VO2 with non-stoichiometry of V2O3±x buffer demonstrates a broadening hysteresis loops width, which is derived from the lattice distortion caused by lattice imperfection. Finally, durability of VO2 has been significantly improved due to positive effects of V2O3 buffer layer. Our results lead to a comprehensive enhancement in crystallinity of VO2 and shed new light on the promotion of thermochromic property by homologous oxides for VO2.

  10. High levels of vegetable oils in plant protein-rich diets fed to gilthead sea bream ( Sparus aurata L.): growth performance, muscle fatty acid profiles and histological alterations of target tissues.

    PubMed

    Benedito-Palos, Laura; Navarro, Juan C; Sitjà-Bobadilla, Ariadna; Bell, J Gordon; Kaushik, Sadasivam; Pérez-Sánchez, Jaume

    2008-11-01

    The feasibility of fish oil (FO) replacement by vegetable oils (VO) was investigated in gilthead sea bream (Sparus aurata L.) in a growth trial conducted for the duration of 8 months. Four isolipidic and isoproteic diets rich in plant proteins were supplemented with L-lysine (0.55 %) and soya lecithin (1 %). Added oil was either FO (control) or a blend of VO, replacing 33 % (33VO diet), 66 % (66VO diet) and 100 % (VO diet) of FO. No detrimental effects on growth performance were found with the partial FO replacement, but feed intake and growth rates were reduced by about 10 % in fish fed the VO diet. The replacement strategy did not damage the intestinal epithelium, and massive accumulation of lipid droplets was not found within enterocytes. All fish showed fatty livers, but signs of lipoid liver disease were only found in fish fed the VO diet. Muscle fatty acid profiles of total lipids reflected the diet composition with a selective incorporation of unsaturated fatty acids in polar lipids. The robustness of the phospholipid fatty acid profile when essential fatty acid requirements were theoretically covered by the diet was evidenced by multivariate principal components analysis in fish fed control, 33VO and 66VO diets.

  11. VOClient: Application Integration in the Virtual Observatory

    NASA Astrophysics Data System (ADS)

    Fitzpatrick, Michael J.; Tody, D.

    2007-12-01

    We present VOClient, a new software package that provides a high-level, easy-to-use, programmable interface between desktop applications and the distributed VO framework, providing access to remote VO data and services, reference implementations for VO data-providers and end-user applications. Applications have traditionally been written to deal directly with local images, catalogs or spectra; VOClient allows these applications to use remote VO data and services without requiring a developer to know the details of the underlying and evolving VO technologies. The programmable interface provides equivalent functionality for a wide variety of both legacy and modern development languages and environments and can be easily extended to add new functionality. The server component of the project provides a reference implementation and toolkit which can be used to build VO data services, and the commandline tools provide ready-to-use applications to access VO data and services from the desktop or scripting environment. The use of VOClient to integrate VO technologies with legacy systems such as IRAF is examined as a case-study, and the use of these techniques in other environments, especially their applicability to legacy code and systems, is also discussed. VOClient is meant both for the astronomer wishing to revive an old and trusted task with new VO capabiities, as well as the institutional project providing data or services to the Virtual Observatory.

  12. Exploring the work function variability and structural stability of VO2(1 1 0) surface upon noble metal (Ag, Au, Pt) adsorption and incorporation

    NASA Astrophysics Data System (ADS)

    Chen, Lanli; Cui, Yuanyuan; Shi, Siqi; Luo, Hongjie; Gao, Yanfeng

    2018-08-01

    Vanadium dioxide (VO2) has attracted great attention, with scientific and technological advances over the past few decades due to its reversible metal-insulator transition at 340 K. However, the high phase transition temperature (Tc) of VO2 limits its practical applications. Our first-principles calculations show that VO2(1 1 0) surfaces with adsorbed noble metals (Ag, Au, Pt) exhibit a lower work function compared with the clean surface and further induces a lower Tc due to charge transfer from the noble metals to the VO2(1 1 0) surface. However, the work functions of the VO2(1 1 0) surfaces after the incorporation of noble metals are higher than that of the clean surface. In addition, the results of formation energies of various configurations show that the VO2(1 1 0) surface with the adsorption and incorporation of Ag is energetically more favorable than those with Au and Pt. Therefore, it may be concluded that the adsorption and incorporation of noble metals can not only tailor the work function of VO2, in turn realizing the rational tuning of Tc of VO2, but also stabilize the structures of VO2 thin films. These results provide guidance for further exploration of VO2-based optical switching devices and smart windows.

  13. Oxidizing annealing effects on VO2 films with different microstructures

    NASA Astrophysics Data System (ADS)

    Dou, Yan-Kun; Li, Jing-Bo; Cao, Mao-Sheng; Su, De-Zhi; Rehman, Fida; Zhang, Jia-Song; Jin, Hai-Bo

    2015-08-01

    Vanadium dioxide (VO2) films have been prepared by direct-current magnetron sputter deposition on m-, a-, and r-plane sapphire substrates. The obtained VO2 films display different microstructures depending on the orientation of sapphire substrates, i.e. mixed microstructure of striped grains and equiaxed grains on m-sapphire, big equiaxed grains on a-sapphire and fine-grained microstructure on r-sapphire. The VO2 films were treated by the processes of oxidation in air. The electric resistance and infrared transmittance of the oxidized films were characterized to examine performance characteristics of VO2 films with different microstructures in oxidation environment. The oxidized VO2 films on m-sapphire exhibit better electrical performance than the other two films. After air oxidization for 600 s at 450 °C, the VO2 films on m-sapphire show a resistance change of 4 orders of magnitude over the semiconductor-to-metal transition. The oxidized VO2 films on a-sapphire have the highest optical modulation efficiency in infrared region compared to other samples. The different performance characteristics of VO2 films are understood in terms of microstructures, i.e. grain size, grain shape, and oxygen vacancies. The findings reveal the correlation of microstructures and performances of VO2 films, and provide useful knowledge for the design of VO2 materials to different applications.

  14. Insulating phases of vanadium dioxide are Mott-Hubbard insulators

    DOE PAGES

    Huffman, T. J.; Hendriks, C.; Walter, E. J.; ...

    2017-02-15

    Here, we present comprehensive broadband optical spectroscopy data on two insulating phases of vanadium dioxide (VO 2): monoclinic M 2 and triclinic. The main result of our work is that the energy gap and the electronic structure are essentially unaltered by the first-order structural phase transition between the M 2 and triclinic phases. Moreover, the optical interband features in the M 2 and triclinic phases are remarkably similar to those observed in the well-studied monoclinic M 1 insulating phase of VO 2. As the energy gap is insensitive to the different lattice structures of the three insulating phases, we rulemore » out vanadium-vanadium pairing (the Peierls component) as the dominant contributor to the opening of the gap. Rather, the energy gap arises primarily from intra-atomic Coulomb correlations.« less

  15. Improving the Accuracy of Predicting Maximal Oxygen Consumption (VO2pk)

    NASA Technical Reports Server (NTRS)

    Downs, Meghan E.; Lee, Stuart M. C.; Ploutz-Snyder, Lori; Feiveson, Alan

    2016-01-01

    Maximal oxygen (VO2pk) is the maximum amount of oxygen that the body can use during intense exercise and is used for benchmarking endurance exercise capacity. The most accurate method to determineVO2pk requires continuous measurements of ventilation and gas exchange during an exercise test to maximal effort, which necessitates expensive equipment, a trained staff, and time to set-up the equipment. For astronauts, accurate VO2pk measures are important to assess mission critical task performance capabilities and to prescribe exercise intensities to optimize performance. Currently, astronauts perform submaximal exercise tests during flight to predict VO2pk; however, while submaximal VO2pk prediction equations provide reliable estimates of mean VO2pk for populations, they can be unacceptably inaccurate for a given individual. The error in current predictions and logistical limitations of measuring VO2pk, particularly during spaceflight, highlights the need for improved estimation methods.

  16. Influence of Nb doping on the phase transition properties of VO2 thin films prepared by ion beam co-sputtering deposition

    NASA Astrophysics Data System (ADS)

    Zhu, Huiqun; Li, Pengfei; Zhao, Lite; Liu, Jiahuan

    2016-03-01

    The Nb-doped VO2 thin films were successfully prepared on the glass substrates by ion beam co-sputtering at room temperature and post annealing under the air condition. The effects of the preparation processing and Nb doping on the thermal hysteresis loop and phase transition temperature of the VO2 thin films were analyzed by resistancetemperature measurement. The results show that Nb doping significantly changes the surface morphologies of VO2 thin films, and Nb-doped VO2 thin films exhibit VO2(002) preferred orientation growth with greatly improved crystallinity and orientation. Compared with pure VO2, the phase transition temperature of Nb-doped VO2 thin films drops to 40 ºC, and the width of thermal hysteresis loop narrows to 8 ºC. It is demonstrated that Nb-doped VO2 thin films prepared by ion beam co-sputtered at room temperature have an obvious thermal sensitive effect, and keep a good characteristic from metal to semiconductor phase transition.

  17. n-VO2/p-GaN based nitride-oxide heterostructure with various thickness of VO2 layer grown by MBE

    NASA Astrophysics Data System (ADS)

    Wang, Minhuan; Bian, Jiming; Sun, Hongjun; Liu, Weifeng; Zhang, Yuzhi; Luo, Yingmin

    2016-12-01

    High quality VO2 films with precisely controlled thickness were grown on p-GaN/sapphire substrates by oxide molecular beam epitaxy (O-MBE). Results indicated that a distinct reversible semiconductor-to-metal (SMT) phase transition was observed for all the samples in the temperature dependent electrical resistance measurement, and the influence of VO2 layer thickness on the SMT properties of the as-grown n-VO2/p-GaN based nitride-oxide heterostructure was investigated. Meanwhile, the clear rectifying transport characteristics originated from the n-VO2/p-GaN interface were demonstrated before and after SMT of the VO2 over layer, which were attributed to the p-n junction behavior and Schottky contact character, respectively. Moreover, the X-ray photoelectron spectroscopy (XPS) analyses confirmed the valence state of vanadium (V) in VO2 films was principally composed of V4+ with trace amount of V5+. The design and modulation of the n-VO2/p-GaN based heterostructure devices will benefit significantly from these achievements.

  18. Spectroscopic analysis of phase constitution of high quality VO2 thin film prepared by facile sol-gel method

    NASA Astrophysics Data System (ADS)

    Wu, Y. F.; Fan, L. L.; Chen, S. M.; Chen, S.; Zou, C. W.; Wu, Z. Y.

    2013-04-01

    VO2 thin films with large-area were prepared on Al2O3 substrates by a simple sol-gel method. After an annealing treatment under low vacuum condition, all the VO2 films showed a preferred growth direction and exhibited excellent semiconductor-metal transition (SMT) characteristics. The structure and electrical properties of the obtained VO2 films were investigated systematically. Raman spectra, X-ray diffraction and X-ray absorption spectra measurements pointed out that the VO2 film on Al_2 O_3 ( {10overline 1 0}) substrate showed a M1 phase instead of M2 phase as reported in previous studies. Based on the experiment results, it was suggested that the strained structure of oriented VO2 films could be a mechanism for the formation of the intermediate M2 phase, whereas it is difficult to access the pure M2 phase of undoped VO2 films. VO2 film on Al_2 O_3 ( {10overline 1 0} ) substrate showed a lower SMT temperature compared to VO2 film on Al2O3 (0001), which can be mostly attributed to the differences of both lattice mismatch and thermal stress. The present results confirm and make clear the relevance of the substrate orientation in the growth of VO2 film and their different contributions to the SMT characteristics in vanadate systems.

  19. Slowed Relaxation in Fatigued Skeletal Muscle Fibers of Xenopus and Mouse

    PubMed Central

    Westerblad, Håkan; Lännergren, Jan; Allen, David G.

    1997-01-01

    Slowing of relaxation is an important characteristic of skeletal muscle fatigue. The aim of the present study was to quantify the relative contribution of altered Ca2+ handling (calcium component) and factors down-stream to Ca2+ (cross-bridge component) to the slowing of relaxation in fatigued fibers of Xenopus and mouse. Two types of Xenopus fibers were used: easily fatigued, type 1 fibers and fatigue resistant, type 2 fibers. In these Xenopus fibers the free myoplasmic [Ca2+] ([Ca2+]i) was measured with indo-1, and the relaxation of Ca2+-derived force, constructed from tetanic [Ca2+]i records and in vivo [Ca2+]i-force curves, was analyzed. An alternative method was used in both Xenopus and mouse fibers: fibers were rapidly shortened during the initial phase of relaxation, and the time to the peak of force redevelopment was measured. These two methods gave similar results and showed proportional slowing of the calcium and cross-bridge components of relaxation in both fatigued type 1 and type 2 Xenopus fibers, whereas only the cross-bridge component was slowed in fatigued mouse fibers. Ca2+ removal from the myoplasm during relaxation was markedly less effective in Xenopus fibers as compared to mouse fibers. Fatigued Xenopus fibers displayed a reduced rate of sarcoplasmic reticulum Ca2+ uptake and increased sarcoplasmic reticulum Ca2+ leak. Some fibers were stretched at various times during relaxation. The resistance to these stretches was increased during fatigue, especially in Xenopus fibers, which indicates that longitudinal movements during relaxation had become less pronounced and this might contribute to the increased cross-bridge component of relaxation in fatigue. In conclusion, slowing of relaxation in fatigued Xenopus fibers is caused by impaired Ca2+ handling and altered cross-bridge kinetics, whereas the slowing in mouse fibers is only due to altered cross-bridge kinetics. PMID:9089444

  20. [Dynamics of oxygen uptake during a 100 m front crawl event, performed during competition ].

    PubMed

    Jalab, Chadi; Enea, Carina; Delpech, Nathalie; Bernard, Olivier

    2011-04-01

    The main purpose of this study is to estimate the dynamics of oxygen uptake (VO2) during a 100 m front crawl event, performed in competition conditions. Eleven trained swimmers participated in 2 separate sessions, in a 25 m swimming pool. Maximal oxygen uptake (VO2max) was determined during a 400 m maximal event. Swimmers also performed a 100 m front crawl in competition conditions, and then, 3 tests (25, 50, and 75 m) following the pacing strategy of the 100 m event. To be free of technical constraints, VO2 was not measured during the tests, but before and just at the end of each test with a 1 min breath-by-breath method. Each post-test VO2 measurement (after 25, 50, 75, and 100 m) allows us to reconstruct the VO2 kinetics of the 100 m performance. Our results differ from previous studies in that VO2 increases faster in the first half of the race (at 50 m, VO2 ≈ 94% VO2max), reaches VO2max at the 75 m mark; then a decrease in VO2 corresponding to 7% of VO2max appears during the last 25 m. These differences are supposed to be mainly the consequences of the adoption of technical elements and a pacing strategy similar to competition conditions. In the future, these observations may lead to different considerations of the bioenergetic contributions.

  1. A simple and low-cost combustion method to prepare monoclinic VO2 with superior thermochromic properties

    PubMed Central

    Cao, Ziyi; Xiao, Xiudi; Lu, Xuanming; Zhan, Yongjun; Cheng, Haoliang; Xu, Gang

    2016-01-01

    In this approach, the VO2 nanoparticles have been successfully fabricated via combusting the low-cost precursor solution consisted of NH4VO3, C2H6O2 and C2H5OH. By the XRD, TEM and XPS analysis, it can be found that the synthetic monoclinic VO2 is single crystal and no impurity is defined. After dispersing the VO2 nanoparticles into the polymer, the solar modulation of VO2-based composite film is up to 12.5% with luminous transmission and haze around 62.2% and 0.5%, respectively. In other words, the composite films show high performance of thermochromic properties. This could open an efficient way to fabricate low-cost and large-scale VO2 (M) nanoparticles and thermochromic films. PMID:27976748

  2. Prediction of maximal oxygen uptake by bioelectrical impedance analysis in overweight adolescents.

    PubMed

    Roberts, M D; Drinkard, B; Ranzenhofer, L M; Salaita, C G; Sebring, N G; Brady, S M; Pinchbeck, C; Hoehl, J; Yanoff, L B; Savastano, D M; Han, J C; Yanovski, J A

    2009-09-01

    Maximal oxygen uptake (VO(2max)), the gold standard for measurement of cardiorespiratory fitness, is frequently difficult to assess in overweight individuals due to physical limitations. Reactance and resistance measures obtained from bioelectrical impedance analysis (BIA) have been suggested as easily obtainable predictors of cardiorespiratory fitness, but the accuracy with which ht(2)/Z can predict VO(2max) has not previously been examined in overweight adolescents. The impedance index was used as a predictor of VO(2max) in 87 overweight girls and 47 overweight boys ages 12 to 17 with mean BMI of 38.6 + or - 7.3 and 42.5 + or - 8.2 in girls and boys respectively. The Bland Altman procedure assessed agreement between predicted and actual VO(2max). Predicted VO(2max) was significantly correlated with measured VO(2max) (r(2)=0.48, P<0.0001). Using the Bland Altman procedure, there was significant magnitude bias (r(2)=0.10; P<0.002). The limits of agreement for predicted relative to actual VO(2max) were -589 to 574 mL O(2)/min. The impedance index was highly correlated with VO(2max) in overweight adolescents. However, using BIA data to predict maximal oxygen uptake over-predicted VO(2max) at low levels of oxygen consumption and under-predicted VO(2max) at high levels of oxygen consumption. This magnitude bias, along with the large limits of agreement of BIA-derived predicted VO(2max), limit its usefulness in the clinical setting for overweight adolescents.

  3. Interval training at 95% and 100% of the velocity at VO2 max: effects on aerobic physiological indexes and running performance.

    PubMed

    Denadai, Benedito S; Ortiz, Marcelo J; Greco, Camila C; de Mello, Marco T

    2006-12-01

    The objective of this study was to analyze the effect of two different high-intensity interval training (HIT) programs on selected aerobic physiological indices and 1500 and 5000 m running performance in well-trained runners. The following tests were completed (n=17): (i) incremental treadmill test to determine maximal oxygen uptake (VO2 max), running velocity associated with VO2 max (vVO2 max), and the velocity corresponding to 3.5 mmol/L of blood lactate concentration (vOBLA); (ii) submaximal constant-intensity test to determine running economy (RE); and (iii) 1500 and 5000 m time trials on a 400 m track. Runners were then randomized into 95% vVO2 max or 100% vVO2 max groups, and undertook a 4 week training program consisting of 2 HIT sessions (performed at 95% or 100% vVO2 max, respectively) and 4 submaximal run sessions per week. Runners were retested on all parameters at the completion of the training program. The VO2 max values were not different after training for both groups. There was a significant increase in post-training vVO2 max, RE, and 1500 m running performance in the 100% vVO2 max group. The vOBLA and 5000 m running performance were significantly higher after the training period for both groups. We conclude that vOBLA and 5000 m running performance can be significantly improved in well-trained runners using a 4 week training program consisting of 2 HIT sessions (performed at 95% or 100% vVO2 max) and 4 submaximal run sessions per week. However, the improvement in vVO2 max, RE, and 1500 m running performance seems to be dependent on the HIT program at 100% vVO2 max.

  4. A comparison of practical assessment methods to determine treadmill, cycle and elliptical ergometer VO2peak

    PubMed Central

    Mays, Ryan J.; Boér, Nicholas F.; Mealey, Lisa M.; Kim, Kevin H.; Goss, Fredric L.

    2015-01-01

    This investigation compared estimated and predicted peak oxygen consumption (VO2peak) and maximal heart rate (HRmax) among the treadmill, cycle ergometer and elliptical ergometer. Seventeen women (mean ± SE: 21.9 ± .3 yrs) exercised to exhaustion on all modalities. ACSM metabolic equations were used to estimate VO2peak. Digital displays on the elliptical ergometer were used to estimate VO2peak. Two individual linear regression methods were used to predict VO2peak: 1) two steady state heart rate (HR) responses up to 85% of age-predicted HRmax, and 2) multiple steady state/non-steady state HR responses up to 85% of age-predicted HRmax. Estimated VO2peak for the treadmill (46.3 ± 1.3 ml · kg−1 · min−1) and the elliptical ergometer (44.4 ± 1.0 ml · kg−1 · min−1) did not differ. The cycle ergometer estimated VO2peak (36.5 ± 1.0 ml · kg−1 · min−1) was lower (p < .001) than the estimated VO2peak values for the treadmill and elliptical ergometer. Elliptical ergometer VO2peak predicted from steady state (51.4 ± .8 ml · kg−1 · min−1) and steady state/non-steady state (50.3 ± 2.0 ml · kg−1 · min−1) models were higher than estimated elliptical ergometer VO2peak, p < .01. HRmax and estimates of VO2peak were similar between the treadmill and elliptical ergometer, thus cross-modal exercise prescriptions may be generated. The use of digital display estimates of submaximal oxygen uptake for the elliptical ergometer may not be an accurate method for predicting VO2peak. Health-fitness professionals should use caution when utilizing submaximal elliptical ergometer digital display estimates to predict VO2peak. PMID:20393357

  5. VO2 responses to intermittent swimming sets at velocity associated with VO2max.

    PubMed

    Libicz, Sebastien; Roels, Belle; Millet, Gregoire P

    2005-10-01

    While the physiological adaptations following endurance training are relatively well understood, in swimming there is a dearth of knowledge regarding the metabolic responses to interval training (IT). The hypothesis tested predicted that two different endurance swimming IT sets would induce differences in the total time the subjects swam at a high percentage of maximal oxygen consumption (VO(2)max). Ten trained triathletes underwent an incremental test to exhaustion in swimming so that the swimming velocity associated with VO(2)max (vVO(2)max) could be determined. This was followed by a maximal 400-m test and two intermittent sets at vVO(2)max: (a) 16 x 50 m with 15-s rest (IT(50)); (b) 8 x 100 m with 30-s rest (IT(100)). The times sustained above 95% VO(2)max (68.50 +/- 62.69 vs. 145.01 +/- 165.91 sec) and 95% HRmax (146.67 +/- 131.99 vs. 169.78 +/- 203.45 sec, p = 0.54) did not differ between IT(50) and IT(100)(values are mean +/- SD). In conclusion, swimming IT sets of equal time duration at vVO(2)max but of differing work-interval durations led to slightly different VO(2)and HR responses. The time spent above 95% of VO(2)max was twice as long in IT(100) as in IT (50), and a large variability between mean VO(2)and HR values was also observed.

  6. Evolution of Structural and Electrical Properties of Oxygen-Deficient VO2 under Low Temperature Heating Process.

    PubMed

    Zhang, Jiasong; Zhao, Zhengjing; Li, Jingbo; Jin, Haibo; Rehman, Fida; Chen, Pengwan; Jiang, Yijie; Chen, Chunxu; Cao, Maosheng; Zhao, Yongjie

    2017-08-16

    Structural stability and functional performances of vanadium dioxide (VO 2 ) are strongly influenced by oxygen vacancies. However, the mechanism of metal-insulator transition (MIT) influenced by defects is still under debate. Here, we study the evolution of structure and electrical property of oxygen-deficient VO 2 by a low temperature annealing process (LTP) based on a truss-structured VO 2 nanonet. The oxygenation process of the oxygen-deficient VO 2 is greatly prolonged, which enables us to probe the gradual change of properties of the oxygen-deficient VO 2 . A continuous lattice reduction is observed during LTP. No recrystallization and structural collapse of the VO 2 nanonet can be found after LTP. The valence-band X-ray photoelectron spectroscopy (XPS) measurements indicate that the oxygen deficiency strongly affects the energy level of the valence band edge. Correspondingly, the resistance changes of the VO 2 films from 1 to 4.5 orders of magnitude are achieved by LTP. The effect of oxygen vacancy on the electric field driven MIT is investigated. The threshold value of voltage triggering the MIT decreases with increasing the oxygen vacancy concentration. This work demonstrates a novel and effective way to control the content of oxygen vacancies in VO 2 and the obvious impact of oxygen vacancy on MIT, facilitating further research on the role of oxygen vacancy in structure and MIT of VO 2 , which is important for the deep understanding of MIT and exploiting innovative functional application of VO 2 .

  7. Preparation and enhanced infrared response properties of ordered W-doped VO2 nanowire array

    NASA Astrophysics Data System (ADS)

    Xie, Bing He; Fu, Wen Biao; Fei, Guang Tao; Xu, Shao Hui; Gao, Xu Dong; Zhang, Li De

    2018-04-01

    In this article, pure and tungsten-doped (W-doped) highly ordered two-dimensional (2D) vanadium dioxide (VO2) nanowire arrays were successfully prepared by a hydrothermal treatment, followed by a self-assembly progress and the in-situ high temperature treatment. The infrared photodetector devices based on monoclinic VO2 (VO2(M)) and W-doped VO2(M) nanowires were comparatively studied . It was found that the device based on W-doped VO2(M) nanowires exhibits a rapid infrared response and an enhanced photoelectric responsivity of 21.4 mA/W under the incident infrared light intensity of 280 mW/cm2, which is nearly two orders of magnitude superior to pure VO2(M) nanowire array. Our experimental results provided a direct and convenient path for design of future high-performance photodetector devices.

  8. Correlation between surface morphology and electrical properties of VO2 films grown by direct thermal oxidation method

    NASA Astrophysics Data System (ADS)

    Yoon, Joonseok; Park, Changwoo; Park, Sungkyun; Mun, Bongjin Simon; Ju, Honglyoul

    2015-10-01

    We investigate surface morphology and electrical properties of VO2 films fabricated by direct thermal oxidation method. The VO2 film prepared with oxidation temperature at 580 °C exhibits excellent qualities of VO2 characteristics, e.g. a metal-insulator transition (MIT) near 67 °C, a resistivity ratio of ∼2.3 × 104, and a bandgap of 0.7 eV. The analysis of surface morphology with electrical resistivity of VO2 films reveals that the transport properties of VO2 films are closely related to the grain size and surface roughness that vary with oxidation annealing temperatures.

  9. Pain threshold is achieved at intensity above anaerobic threshold in patients with intermittent claudication.

    PubMed

    Ritti-Dias, Raphael Mendes; de Moraes Forjaz, Cláudia Lúcia; Cucato, Gabriel Grizzo; Costa, Luis Augusto Riani; Wolosker, Nelson; de Fátima Nunes Marucci, Maria

    2009-01-01

    Walking training is considered as the first treatment option for patients with peripheral arterial disease and intermittent claudication (IC). Walking exercise has been prescribed for these patients by relative intensity of peak oxygen uptake (VO2peak), ranging from 40% to 70% VO2peak, or pain threshold (PT). However, the relationship between these methods and anaerobic threshold (AT), which is considered one of the best metabolic markers for establishing training intensity, has not been analyzed. Thus, the aim of this study was to compare, in IC patients, the physiological responses at exercise intensities usually prescribed for training (% VO2peak or % PT) with the ones observed at AT. Thirty-three IC patients performed maximal graded cardiopulmonary treadmill test to assess exercise tolerance. During the test, heart rate (HR), VO2, and systolic blood pressure were measured and responses were analyzed at the following: 40% of VO2peak; 70% of VO2peak; AT; and PT. Heart rate and VO2 at 40% and 70% of VO2peak were lower than those at AT (HR: -13 +/- 9% and -3 +/- 8%, P < .01, respectively; VO2: -52 +/- 12% and -13 +/- 15%, P < .01, respectively). Conversely, HR and VO2 at PT were slightly higher than those at AT (HR: +3 +/- 8%, P < .01; VO2: +6 +/- 15%, P = .04). None of the patients achieved the respiratory compensation point. Prescribing exercise for IC patients between 40% and 70% of VO2peak will induce a lower stimulus than that at AT, whereas prescribing exercise at PT will result in a stimulus above AT. Thus, prescribing exercise training for IC patients on the basis of PT will probably produce a greater metabolic stimulus, promoting better cardiovascular benefits.

  10. Oxygen Costs of the Incremental Shuttle Walk Test in Cardiac Rehabilitation Participants: An Historical and Contemporary Analysis.

    PubMed

    Buckley, John P; Cardoso, Fernando M F; Birkett, Stefan T; Sandercock, Gavin R H

    2016-12-01

    The incremental shuttle walk test (ISWT) is a standardised assessment for cardiac rehabilitation. Three studies have reported oxygen costs (VO 2 )/metabolic equivalents (METs) of the ISWT. In spite of classic representations from these studies graphically showing curvilinear VO 2 responses to incremented walking speeds, linear regression techniques (also used by the American College of Sports Medicine [ACSM]) have been used to estimate VO 2 . The two main aims of this study were to (i) resolve currently reported discrepancies in the ISWT VO 2 -walking speed relationship, and (ii) derive an appropriate VO 2 versus walking speed regression equation. VO 2 was measured continuously during an ISWT in 32 coronary heart disease [cardiac] rehabilitation (CHD-CR) participants and 30 age-matched controls. Both CHD-CR and control group VO 2 responses were curvilinear in nature. For CHD-CR VO 2  = 4.4e 0.23 × walkingspeed (km/h) . The integrated area under the curve (iAUC) VO 2 across nine ISWT stages was greater in the CHD-CR group versus the control group (p < 0.001): CHD-CR = 423 (±86) ml·kg -1 ·min -1 ·km·h -1 ; control = 316 (±52) ml·kg -1 ·min -1 ·km·h -1 . CHD-CR group vs. control VO 2 was up to 30 % greater at higher ISWT stages. The curvilinear nature of VO 2 responses during the ISWT concur with classic studies reported over 100 years. VO 2 estimates for walking using linear regression models (including the ACSM) clearly underestimate values in healthy and CHD-CR participants, and this study provides a resolution to this when the ISWT is used for CHD-CR populations.

  11. Impact of isovalent doping on radiation defects in silicon

    NASA Astrophysics Data System (ADS)

    Londos, C. A.; Sgourou, E. N.; Timerkaeva, D.; Chroneos, A.; Pochet, P.; Emtsev, V. V.

    2013-09-01

    Isovalent doping is an important process for the control of point defects in Si. Here, by means of infrared spectroscopy, we investigated the properties of the two main radiation-induced defects in Czochralski-Si (Cz-Si) the oxygen-vacancy (VO) and the carbon-oxygen (CiOi) centres. In particular, we investigated the effect of isovalent doping on the production, the thermal evolution, and the thermal stability of the VO and the CiOi defects. Additionally, we studied the reactions that participate upon annealing and the defects formed as a result of these reactions. Upon annealing VO is converted to VO2 defect although part of the CiOi is converted to CsO2i complexes. Thus, we studied the conversion ratios [VO2]/[VO] and [CsO2i]/[CiOi] with respect to the isovalent dopant. Additionally, the role of carbon in the above processes was discussed. A delay between the temperature characterizing the onset of the VO decay and the temperature characterizing the VO2 growth as well the further growth of VO2 after the complete disappearance of VO indicate that the VO to VO2 conversion is a complex phenomenon with many reaction processes involved. Differences exhibited between the effects of the various dopants on the properties of the two defects were highlighted. The results are discussed in view of density functional theory calculations involving the interaction of isovalent dopants with intrinsic defects, the oxygen and carbon impurities in Si.

  12. Cell-surface properties of Vibrio ordalii strains isolated from Atlantic salmon Salmo salar in Chilean farms.

    PubMed

    Ruiz, P; Poblete, M; Yáñez, A J; Irgang, R; Toranzo, A E; Avendaño-Herrera, R

    2015-02-10

    Vibrio ordalii is the causative agent of atypical vibriosis and has the potential to cause severe losses in salmonid aquaculture, but the factors determining its virulence have not yet been elucidated. In this work, cell-surface-related properties of the isolates responsible for outbreaks in Atlantic salmon were investigated. We also briefly examined whether pathogenicity against fish varied for V. ordalii strains with differing cell-surface properties. Hydrocarbon adhesions indicated the hydrophobic character of V. ordalii, although only 4 of 18 isolates induced haemagglutination in Atlantic salmon erythrocytes. A minority of the studied isolates (6 of 18) and the type strain ATCC 33509T produced low-grade biofilm formation on polyethylene surface after 2 h post-inoculation (hpi), but no strains were slime producers. Interestingly, V. ordalii isolates showed wide differences in hydrophobicity. Therefore, we chose 3 V. ordalii isolates (Vo-LM-03, Vo-LM-18 and Vo-LM-16) as representative of each hydrophobicity group (strongly hydrophobic, relatively hydrophobic and quasi-hydrophilic, respectively) and ATCC 33509T was used in the pathogenicity studies. All tested V. ordalii strains except the type strain resisted the killing activity of Atlantic salmon mucus and serum, and could proliferate in these components. Moreover, all V. ordalii isolates adhered to SHK-1 cells, causing damage to fish cell membrane permeability after 16 hpi. Virulence testing using rainbow trout revealed that isolate Vo-LM-18 was more virulent than isolates Vo-LM-03 and Vo-LM-16, indicating some relationship between haemagglutination and virulence, but not with hydrophobicity.

  13. Electronic structure of HxVO2 probed with in-situ spectroscopic ellipsometry

    NASA Astrophysics Data System (ADS)

    Kim, So Yeun; Sandilands, Luke J.; Kang, Taedong; Son, Jaeseok; Sohn, C. H.; Yoon, Hyojin; Son, Junwoo; Moon, S. J.; Noh, T. W.

    Vanadium dioxide (VO2) undergoes a metal-to-insulator transition (MIT) near 340K. Despite extensive studies on this material, the role of electron-electron correlation and electron-lattice interactions in driving this MIT is still under debate. Recently, it was demonstrated that hydrogen can be reversibly absorbed into VO2 thin film without destroying the lattice framework. This H-doping allows systematic control of the electron density and lattice structure which in turn leads to a insulator (VO2) - metal (HxVO2) - insulator (HVO2) phase modulation. To better understand the phase modulation of HxVO2, we used in-situ spectroscopic ellipsometry to monitor the electronic structure during the hydrogenization process, i.e. we measured the optical conductivity of HxVO2 while varying x. Starting in the high temperature rutile metallic phase of VO2, we observed a large change in the electronic structure upon annealing in H gas at 370K: the low energy conductivity is continuously suppressed, consistent with reported DC resistivity data, while the conductivity peaks at high energy show strong changes in energy and spectral weight. The implications of our results for the MIT in HxVO2 will be discussed.

  14. Influence of work-interval intensity and duration on time spent at a high percentage of VO2max during intermittent supramaximal exercise.

    PubMed

    Wakefield, Benjamin R; Glaister, Mark

    2009-12-01

    The purpose of this study was to examine the effect of work-interval duration (WID) and intensity on the time spent at, or above, 95% VO2max (T95 VO2max) during intermittent bouts of supramaximal exercise. Over a 5-week period, 7 physically active men with a mean (+/-SD) age, height, body mass, and VO2max of 22 +/- 5 years, 181.5 +/- 5.6 cm, 86.4 +/- 11.4 kg, and 51.5 +/- 1.5 ml.kg-1.min-1, respectively, attended 7 testing sessions. After completing a submaximal incremental test on a treadmill to identify individual oxygen uptake/running velocity relationships, subjects completed a maximal incremental test to exhaustion to VO2max and subsequently (from the aforementioned relationship) the minimum velocity required to elicit VO2max (vVO2max). In a random order, subjects then carried out 3 intermittent runs to exhaustion at both 105% and 115% vVO2max. Each test used a different WID (20 s, 25 s, or 30 s) interspersed with 20-second passive recovery periods. Results revealed no significant difference in T95 vVO2max for intermittent runs at 105% versus 115% vVO2max (p = 0.142). There was, however, a significant effect (p < 0.001) of WID on T95 VO2max, with WIDs of 30 seconds enabling more time relative to WIDs of 20 seconds (p = 0.018) and 25 seconds (p = 0.009). Moreover, there was an interaction between intensity and duration such that the effect of WID was magnified at the lower exercise intensity (p = 0.046). In conclusion, despite a number of limitations, the results of this investigation suggest that exercise intensities of approximately 105% vVO2max combined with WIDs greater than 25 seconds provide the best way of optimizing T95 VO2max when using fixed 20-second stationary rest periods.

  15. Compare the phase transition properties of VO2 films from infrared to terahertz range

    NASA Astrophysics Data System (ADS)

    Liang, Shan; Shi, Qiwu; Huang, Wanxia; Peng, Bo; Mao, Zhenya; Zhu, Hongfu

    2018-06-01

    VO2 with reversible semiconductor-metal phase transition properties is particularly available for the application in smart opto-electrical devices. However, there are rare reports on comparing its phase transition properties at different ranges. In this study, the VO2 films are designed with the similar crystalline structure and stoichiometry, but different morphologies by inorganic and organic sol-gel methods, and their phase transition characteristics are compared both at infrared and terahertz range. The results indicate that the VO2 film prepared by inorganic sol-gel method shows more compact nanostructure. It results in larger resistivity change, infrared and terahertz switching ratio in the VO2 film. Moreover, it presents that the phase transition intensity of VO2 film in terahertz range is more sensitive to its microstructure. This work is helpful for understanding the susceptibility of terahertz switching properties of VO2 to its microstructure. And it can provide insights for the applications of VO2 in terahertz smart devices.

  16. Determinants of a simulated cross-country skiing sprint competition using V2 skating technique on roller skis.

    PubMed

    Mikkola, Jussi; Laaksonen, Marko; Holmberg, Hans-Christer; Vesterinen, Ville; Nummela, Ari

    2010-04-01

    The present study investigated the performance-predicting factors of a simulated cross-country (XC) skiing sprint competition on roller skis, on a slow surface. Sixteen elite male XC skiers performed a simulated sprint competition (4 x 850 m heat with a 20-minute recovery) using V2 skating technique on an indoor tartan track. Heat velocities, oxygen consumption, and peak lactate were measured during or after the heats. Maximal skiing velocity was measured by performing a 30-m speed test. Explosive and maximal force production in the upper body was determined by bench press (BP). Subjects also performed maximal anaerobic skiing test (MAST) and the 2 x 2-km double poling (DP) test. The maximal velocity of MAST (VMAST) and velocities at 3 (V3), 5 (V5), 7 (V7) mmol.L lactate levels in MAST were determined. In the 2 x 2-km test, DP economy (VO2SUBDP) and maximal 2-km DP velocity (VDP2KM) were determined. The best single performance-predicting factors for the sprint performance were VDP2KM (r = 0.73, p < 0.01), V7 (r = 0.70, p < 0.01), and VO2SUBDP (r = -0.70, p < 0.01). Faster skiers in sprint simulation had a higher absolute VO2 (L.min) (p < 0.05-0.01) during sprint heats, and higher anaerobic skiing power (VMAST, p < 0.05) and better anaerobic skiing economy (V3, V5, V7, p < 0.05-0.001) than slower skiers. Faster skiers were also stronger in BP, with regard to both absolute (p < 0.01) and relative (p < 0.05) values. In addition, anaerobic characteristics seem to be of importance at the beginning of the XC skiing sprint competition, whereas the aerobic characteristics become more important as the XC skiing sprint competition progressed. This study indicates that sprint skiers should emphasize sport-specific upper body training, and training skiing economy at high speeds.

  17. Infrastructure and the Virtual Observatory

    NASA Astrophysics Data System (ADS)

    Dowler, P.; Gaudet, S.; Schade, D.

    2011-07-01

    The modern data center is faced with architectural and software engineering challenges that grow along with the challenges facing observatories: massive data flow, distributed computing environments, and distributed teams collaborating on large and small projects. By using VO standards as key components of the infrastructure, projects can take advantage of a decade of intellectual investment by the IVOA community. By their nature, these standards are proven and tested designs that already exist. Adopting VO standards saves considerable design effort, allows projects to take advantage of open-source software and test suites to speed development, and enables the use of third party tools that understand the VO protocols. The evolving CADC architecture now makes heavy use of VO standards. We show examples of how these standards may be used directly, coupled with non-VO standards, or extended with custom capabilities to solve real problems and provide value to our users. In the end, we use VO services as major parts of the core infrastructure to reduce cost rather than as an extra layer with additional cost and we can deliver more general purpose and robust services to our user community.

  18. Preparation and characterization of self-supporting thermochromic films composed of VO2(M)@SiO2 Nanofibers.

    PubMed

    Li, Shaotang; Li, Yamei; Jiang, Meng; Ji, Shidong; Luo, Hongjie; Gao, Yanfeng; Jin, Ping

    2013-07-24

    Nanofibers of VO2(A) with the diameter and length averagely at 100 nm and 10-20 μm were prepared via a facile one-step hydrothermal method by reducing NH4VO3 with 1,3-propylene glycol in an acidic solution. The obtained VO2(A) was coated by SiO2 to form VO2(A)@SiO2 core-shell nanocomposites, which were then transformed into VO2(M)@SiO2 by annealing under nitrogen atmosphere. The resulted composites maintained the original fibrous morphology, particularly with a large amount of pores emerging inside the fiber due to the volume shrinkage during the phase transition, which may improve its thermal insulation ability in real applications. The VO2(M)@SiO2 nanofibers were arranged into a self-supporting film by filtration, which shows excellent thermochromic properties.

  19. Oxygen consumption of the chicken embryo: interaction between temperature and oxygenation.

    PubMed

    Mortola, Jacopo P; Labbè, Katherine

    2005-03-01

    We measured the effects of hypoxia and changes in ambient temperature (T) on the oxygen consumption (VO2) of chicken embryos at embryonic days 11, 16 and 20 (E11, E16 and E20, respectively), and post-hatching day 1 (H1). Between 30 and 39 degrees C, at E11 and E16, VO2 changed linearly with T, as in ectothermic animals, with a Q10 of about 2.1. At E20, VO2 did not significantly change with T, indicating the onset of endothermy. At H1, a drop in T increased VO2, a clear thermogenic response. Hypoxia (11% O2 for 30 min) decreased VO2, by an amount that varied with T and age. At H1, hypoxia lowered VO2 especially at low T. At E20, hypoxic hypometabolism was similar at all T. At E11 and E16, hypoxia lowered VO2 only at the higher T. In fact, at E11, with T=39 degrees C even a modest hypoxia (15-18% O2) decreased VO2. Upon return to normoxia after 40 min of 11% O2, VO2 did not rise above the pre-hypoxic level, indicating that the hypometabolism during hypoxia did not generate an O2 debt. At E11, during modest hypoxia (16% O2) at 36 degrees C, the drop in VO2 was lifted by raising the T to 39 degrees C, suggesting that the hypoxic hypometabolism at 36 degrees C was not due to O2-supply limitation. In conclusion, the hypometabolic effects of hypoxia on the chicken embryo's VO2 depend on the development of the thermogenic ability, occurring predominantly at high T during the early (ectothermic phase) and at low T during the late (endothermic) phase. At E11, both low T and low oxygen force VO2 to drop. However, at a near-normal T, modest hypoxia promotes a hypometabolic response with the characteristics of regulated O2 conformism.

  20. Complexes of oxovanadium(IV), dioxovanadium(V) and dioxouranium(VI) with aminoacids in aqueous solution

    NASA Astrophysics Data System (ADS)

    Lagrange, P.; Schneider, M.; Lagrange, J.

    1998-11-01

    The equilibria between three oxocations (VO2+, VO2+ and UO22+) and several ?- aminoacids (glycine, serine, asparagine, lysine, aspartic acid and glutamic acid) are studied in aqueous solution. Stoichiometry and stability of the complexes formed are determined from a combination of potentiometric and spectroscopic measurements. Solution structures of the different complexes are proposed based on the thermodynamic results. The oxovanadium(IV) complexes appear less stable than the corresponding dioxouranium(VI) and dioxovanadium(V) complexes. VO2+ can be bound to only one ligand to form monodentate or chelate complexes. UO22+ and VO2+ cations may be chelated by one or two ligands. Les équilibres entre trois oxocations, VO2+, VO2+ et UO22+ et plusieurs α-aminoacides, glycine, sérine, asparagine, lysine et acides aspartique et glutamique, sont étudiés en solution aqueuse par potentiométrie couplée à la spectrophotométrie. Les complexes de VO2+ sont moins stables que les complexes de VO2+ et UO22+ de même stoechiométrie. VO2+ ne peut se lier qu'à un seul ligand pour former soit des complexes monodentés, soit des chélates. UO22+ et VO2+ peuvent être chélatés par un ou deux ligands. Des structures hypothétiques en solution sont proposées.

  1. Comparison of distribution and toxicity following repeated oral dosing of different vanadium oxide nanoparticles in mice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Eun-Jung, E-mail: pejtoxic@hanmail.net

    Vanadium is an important ultra-trace element derived from fuel product combustion. With the development of nanotechnology, vanadium oxide nanoparticles (VO NPs) have been considered for application in various fields, thus the possibility of release into the environment and human exposure is also increasing. Considering that verification of bioaccumulation and relevant biological responses are essential for safe application of products, in this study, we aimed to identify the physicochemical properties that determine their health effects by comparing the biological effects and tissue distribution of different types of VO NPs in mice. For this, we prepared five types of VO NPs, commercialmore » (C)-VO{sub 2} and -V{sub 2}O{sub 5} NPs and synthetic (S)-VO{sub 2}, -V{sub 2}O{sub 3,} and -V{sub 2}O{sub 5} NPs. While the hydrodynamic diameter of the two types of C-VO NPs was irregular and impossible to measure, those of the three types of S-VO NPs was in the range of 125–170 nm. The S- and C-V{sub 2}O{sub 5} NPs showed higher dissolution rates compared to other VO NPs. We orally dosed the five types of VO NPs (70 and 210 μg/mouse, approximately 2 and 6 mg/kg) to mice for 28 days and compared their biodistribution and toxic effects. We found that S-V{sub 2}O{sub 5} and S-V{sub 2}O{sub 3} NPs more accumulated in tissues compared to other three types of VO NPs, and the accumulated level was in order of heart>liver>kidney>spleen. Additionally, tissue levels of redox reaction-related elements and electrolytes (Na{sup +}, K{sup +}, and Ca{sup 2+}) were most clearly altered in the heart of treated mice. Notably, all S- and C-VO NPs decreased the number of WBCs at the higher dose, while total protein and albumin levels were reduced at the higher dose of S-V{sub 2}O{sub 5} and S-V{sub 2}O{sub 3} NPs. Taken together, we conclude that the biodistribution and toxic effects of VO NPs depend on their dissolution rates and size (surface area). Additionally, we suggest that further studies are needed to clarify effects of VO NPs on functions of the heart and the immune system. - Highlights: • We used commercial (C)-VO{sub 2} and -V{sub 2}O{sub 5} and synthetic (S)-VO{sub 2}, -V{sub 2}O{sub 3,} and -V{sub 2}O{sub 5} NPs. • The S- and C-V{sub 2}O{sub 5} NPs showed higher dissolution rates compared to other VO NPs. • S-V{sub 2}O{sub 5} and S-V{sub 2}O{sub 3} NPs more accumulated in tissues compared to other types of VO NPs. • Redox reaction-related elements and electrolytes were clearly altered in the heart. • With decreased body weight, immune and blood-related factors influence by all VO NPs. • Biodistribution and toxicity of VO NPs depend on their dissolution rates and size.« less

  2. Research progress of VO2 thin film as laser protecting material

    NASA Astrophysics Data System (ADS)

    Liu, Zhiwei; Lu, Yuan; Hou, Dianxin

    2018-03-01

    With the development of laser technology, the battlefield threat of directional laser weapons is becoming more and more serious. The blinding and destruction caused by laser weapons on the photoelectric equipment is an important part of the current photo-electronic warfare. The research on the defense technology of directional laser weapons based on the phase transition characteristics of VO2 thin films is an important subject. The researches of VO2 thin films are summarized based on review these points: the preparation methods of VO2 thin films, phase transition mechanism, phase transition temperature regulating, interaction between VO2 thin films and laser, and the application prospect of vo2 thin film as laser protecting material. This paper has some guiding significance for further research on the VO2 thin films in the field of defense directional laser weapons.

  3. The annealing mechanism of the radiation-induced vacancy-oxygen defect in silicon

    NASA Astrophysics Data System (ADS)

    Voronkov, V. V.; Falster, R.; Londos, C. A.

    2012-06-01

    Annealing experiments on the VO defect (the A-centre) produced by radiation in silicon—reported long ago—have been re-examined in order to deduce the two most important properties of VO: its diffusivity and the equilibrium constant for VO dissociation into V + O. The loss rate of VO is accounted for by two major reactions. One is the conventional reaction of the trapping of mobile VO by oxygen, thus producing VO2. The other is an annihilation of vacancies, which coexist in an equilibrium ratio with VO, by radiation-produced interstitial point defects. In some cases, a minor reaction, VO + V, should also be taken into account. The emerging minor defects V2O are also highly mobile. They partially dissociate back and partially get trapped by oxygen producing stable V2O2 defects.

  4. Vanadium(V) Complexes with Substituted 1,5-bis(2-hydroxybenzaldehyde)carbohydrazones and Their Use As Catalyst Precursors in Oxidation of Cyclohexane.

    PubMed

    Dragancea, Diana; Talmaci, Natalia; Shova, Sergiu; Novitchi, Ghenadie; Darvasiová, Denisa; Rapta, Peter; Breza, Martin; Galanski, Markus; Kožı́šek, Jozef; Martins, Nuno M R; Martins, Luísa M D R S; Pombeiro, Armando J L; Arion, Vladimir B

    2016-09-19

    Six dinuclear vanadium(V) complexes have been synthesized: NH4[(VO2)2((H)LH)] (NH4[1]), NH4[(VO2)2((t-Bu)LH)] (NH4[2]), NH4[(VO2)2((Cl)LH)] (NH4[3]), [(VO2)(VO)((H)LH)(CH3O)] (4), [(VO2)(VO)((t-Bu)LH)(C2H5O)] (5), and [(VO2)(VO)((Cl)LH)(CH3O)(CH3OH/H2O)] (6) (where (H)LH4 = 1,5-bis(2-hydroxybenzaldehyde)carbohydrazone, (t-Bu)LH4 = 1,5-bis(3,5-di-tert-butyl-2-hydroxybenzaldehyde)carbohydrazone, and (Cl)LH4 = 1,5-bis(3,5-dichloro-2-hydroxybenzaldehyde)carbohydrazone). The structures of NH4[1] and 4-6 have been determined by X-ray diffraction (XRD) analysis. In all complexes, the triply deprotonated ligand accommodates two V ions, using two different binding sites ONN and ONO separated by a diazine unit -N-N-. In two pockets of NH4[1], two identical VO2(+) entities are present, whereas, in those of 4-6, two different VO2(+) and VO(3+) are bound. The highest oxidation state of V ions was corroborated by X-ray data, indicating the presence of alkoxido ligand bound to VO(3+) in 4-6, charge density measurements on 4, magnetic susceptibility, NMR spectroscopy, spectroelectrochemistry, and density functional theory (DFT) calculations. All four complexes characterized by XRD form dimeric associates in the solid state, which, however, do not remain intact in solution. Compounds NH4[1], NH4[2], and 4-6 were applied as alternative selective homogeneous catalysts for the industrially significant oxidation of cyclohexane to cyclohexanol and cyclohexanone. The peroxidative (with tert-butyl hydroperoxide, TBHP) oxidation of cyclohexane was performed under solvent-free and additive-free conditions and under low-power microwave (MW) irradiation. Cyclohexanol and cyclohexanone were the only products obtained (high selectivity), after 1.5 h of MW irradiation. Theoretical calculations suggest a key mechanistic role played by the carbohydrazone ligand, which can undergo reduction, instead of the metal itself, to form an active reduced form of the catalyst.

  5. Comparison of upright LBPP and supine LBNP in terms of cardiovascular and biomechanical parameters to simulate 1/6-G (lunar gravity) and 3/8-G (Martian gravity) activities

    NASA Astrophysics Data System (ADS)

    Schlabs, Thomas; Rosales-Velderrain, Armando; Ruckstuhl, Heidi; Richardson, Sara E.; Hargens, Alan

    Background: Missions of astronauts to Moon and Mars may be planned in the future. From over 40 years of manned spaceflight it is known that the human body experiences cardiovascular and musculoskeletal losses and a decrease in aerobic fitness while exposed to reduced gravity. Because future missions will be much longer than before, further research is needed to improve Earth-based simulations of reduced gravity. Among others, two methods are capable of simu-lating fractional gravity on Earth: upright Lower Body Positive Pressure (LBPP) and supine Lower Body Negative Pressure (LBNP). No previous study has directly compared these two methods to determine which method is better suited to simulate both the biomechanical and cardiovascular responses of performing activity in lunar (1/6-G) and Martian (3/8-G) gravities. Taken previous studies into account and considering the fact that supine posture is closer to the established 10 head-up-tilt lunar simulation, we hypothesized that exercise performed in supine LBNP better simulates the cardiovascular conditions that occur in lunar and Martian gravities. Methods: 12 healthy normal subjects underwent a protocol consisting of resting and walking (0.25 Froude) with LBNP and LBPP. Each protocol was performed in simulated 1/6-G and 3/8-G. Heart-rate (HR), blood pressure, oxygen consumption (VO2), vertical component of the ground reaction force, comfort of the subject and perceived exertion of the subject (Borg Scale) were assessed. The obtained parameters were compared to predicted values for lunar and Martian gravity conditions in order to determine the method that shows the best level of agreement. Results: There was no difference in gait parameters between LBPP and LBNP simulation of lunar and Martian gravity (cadence: P=0.427, normalized stride length: P=0.373, duty fac-tor: P=0.302, and normalized vertical peak force (P=0.064). Mean blood pressure (P=0.398), comfort (P=0.832) and BORG rating (P=0.186) did not differ between the two methods. How-ever, we found that the heart rate (P=0.022) and VO2 (P=0.038) were significantly higher during LBPP (HRM oon =74±3 bpm, HRM ars =80±3 bpm, VO2M oon =4.6±0.22 l*kg-1 *min-1 , VO2M ars =6.17±0.38 l*kg-1 *min-1 ) than in LBNP (HRM oon =72±3 bpm, HRM ars =77±3 bpm, VO2M oon =4.66±0.43 l*kg-1 *min-1 , VO2M ars =5.66±0.42 l*kg-1 *min-1 ). A further analysis of deviation from the predicted parameters (HRM oon =77 bpm, HRM ars =84 bpm, VO2M oon =5.40 l*kg-1 *min-1 , VO2M ars =7.14 l*kg-1 *min-1 ) revealed a smaller deviation for LBPP (∆HR=4 bpm, ∆VO2=0.89 l*kg-1 *min-1 ) as compared to LBNP (∆HR=6 bpm, ∆VO2=1.11 l*kg-1 *min-1 ). Discussion: We conclude that biomechanical characteristics of gait are not different between supine LBNP and upright LBPP. In terms of cardiovascular parameters there are only differ-ences in heart rate and VO2. The higher heart rate during upright LBPP is probably due to a lower preload of the heart; as venous return is attenuated when the subject is positioned upright instead of supine. The higher VO2 during upright LBPP reflects the increased activity of anti-gravity muscles working to keep the upper body in balance without body suspension. Most skeletal muscles are not used when lying at rest in supine LBNP. Considering that values for heart rate and VO2 produced with the LBPP simulation had a smaller deviation from the predicted values than with the LBNP simulation, we conclude that upright LBPP is obviously better suited to simulate both lunar and Martian activities.

  6. Experimental and theoretical study of the reactions between neutral vanadium oxide clusters and ethane, ethylene, and acetylene.

    PubMed

    Dong, Feng; Heinbuch, Scott; Xie, Yan; Rocca, Jorge J; Bernstein, Elliot R; Wang, Zhe-Chen; Deng, Ke; He, Sheng-Gui

    2008-02-13

    Reactions of neutral vanadium oxide clusters with small hydrocarbons, namely C2H6, C2H4, and C2H2, are investigated by experiment and density functional theory (DFT) calculations. Single photon ionization through extreme ultraviolet (EUV, 46.9 nm, 26.5 eV) and vacuum ultraviolet (VUV, 118 nm, 10.5 eV) lasers is used to detect neutral cluster distributions and reaction products. The most stable vanadium oxide clusters VO2, V2O5, V3O7, V4O10, etc. tend to associate with C2H4 generating products V(m)O(n)C2H4. Oxygen-rich clusters VO3(V2O5)(n=0,1,2...), (e.g., VO3, V3O8, and V5O13) react with C2H4 molecules to cause a cleavage of the C=C bond of C2H4 to produce (V2O5)(n)VO2CH2 clusters. For the reactions of vanadium oxide clusters (V(m)O(n)) with C2H2 molecules, V(m)O(n)C2H2 are assigned as the major products of the association reactions. Additionally, a dehydration reaction for VO3 + C2H2 to produce VO2C2 is also identified. C2H6 molecules are quite stable toward reaction with neutral vanadium oxide clusters. Density functional theory calculations are employed to investigate association reactions for V2O5 + C2H(x). The observed relative reactivity of C2 hydrocarbons toward neutral vanadium oxide clusters is well interpreted by using the DFT calculated binding energies. DFT calculations of the pathways for VO3+C2H4 and VO3+C2H2 reaction systems indicate that the reactions VO3+C2H4 --> VO2CH2 + H2CO and VO3+C2H2 --> VO2C2 + H2O are thermodynamically favorable and overall barrierless at room temperature, in good agreement with the experimental observations.

  7. Abnormal end-tidal PO(2) and PCO(2) at the anaerobic threshold correlate well with impaired exercise gas exchange in patients with left ventricular dysfunction.

    PubMed

    Kano, Hiroto; Koike, Akira; Hoshimoto-Iwamoto, Masayo; Nagayama, Osamu; Sakurada, Koji; Suzuki, Takeya; Tsuneoka, Hidekazu; Sawada, Hitoshi; Aizawa, Tadanori; Wasserman, Karlman

    2012-01-01

    The aim of the present study was to compare the end-tidal O(2) pressure (PETO(2)) to end-tidal CO(2) pressure (PETCO(2)) in cardiac patients during rest and during 2 states of exercise: at anaerobic threshold (AT) and at peak. The purpose was to see which metabolic state, PETO(2) or PETCO(2), best correlated with exercise limitation. Thirty-eight patients with left ventricular (LV) ejection fraction <40% underwent cardiopulmonary exercise testing (CPX). PETO(2) and PETCO(2) were measured during CPX, along with peak O(2) uptake (VO(2)), AT, slope of the increase in ventilation (VE) relative to the increase in CO(2) output (VCO(2)) (VE vs. VCO(2) slope), and the ratio of the increase in VO(2) to the increase in work rate (ΔVO(2)/ΔWR). Both PETO(2) and PETCO(2) measured at AT were best correlated with peakVO(2), AT, ΔVO(2)/ΔWR and VE vs. VCO(2) slope. PETO(2) at AT correlated with reduced peak VO(2) (r=-0.60), reduced AT (r=-0.52), reduced ΔVO(2)/ΔWR (r=-0.55) and increased VE vs. VCO(2) slope (r=0.74). PETCO(2) at AT correlated with reduced peak VO(2) (r=0.67), reduced AT (r=0.61), reduced ΔVO(2)/ΔWR (r=0.58) and increased VE vs. VCO(2) slope (r=-0.80). PETCO(2) and PETO(2) at AT correlated with peak VO(2), AT and ΔVO(2)/ΔWR, but best correlated with increased VE vs. VCO(2) slope. PETO(2) and PETCO(2) at AT can be used as a prime index of impaired cardiopulmonary function during exercise in patients with LV failure.

  8. Virtual Observatory Interfaces to the Chandra Data Archive

    NASA Astrophysics Data System (ADS)

    Tibbetts, M.; Harbo, P.; Van Stone, D.; Zografou, P.

    2014-05-01

    The Chandra Data Archive (CDA) plays a central role in the operation of the Chandra X-ray Center (CXC) by providing access to Chandra data. Proprietary interfaces have been the backbone of the CDA throughout the Chandra mission. While these interfaces continue to provide the depth and breadth of mission specific access Chandra users expect, the CXC has been adding Virtual Observatory (VO) interfaces to the Chandra proposal catalog and observation catalog. VO interfaces provide standards-based access to Chandra data through simple positional queries or more complex queries using the Astronomical Data Query Language. Recent development at the CDA has generalized our existing VO services to create a suite of services that can be configured to provide VO interfaces to any dataset. This approach uses a thin web service layer for the individual VO interfaces, a middle-tier query component which is shared among the VO interfaces for parsing, scheduling, and executing queries, and existing web services for file and data access. The CXC VO services provide Simple Cone Search (SCS), Simple Image Access (SIA), and Table Access Protocol (TAP) implementations for both the Chandra proposal and observation catalogs within the existing archive architecture. Our work with the Chandra proposal and observation catalogs, as well as additional datasets beyond the CDA, illustrates how we can provide configurable VO services to extend core archive functionality.

  9. Electronic structure and insulating gap in epitaxial VO 2 polymorphs

    DOE PAGES

    Lee, Shinbuhm; Meyer, Tricia L.; Sohn, Changhee; ...

    2015-12-24

    Here, determining the origin of the insulating gap in the monoclinic VO 2(M1) is a long-standing issue. The difficulty of this study arises from the simultaneous occurrence of structural and electronic transitions upon thermal cycling. Here, we compare the electronic structure of the M1 phase with that of single crystalline insulating VO 2(A) and VO 2(B) thin films to better understand the insulating phase of VO 2. As these A and B phases do not undergo a structural transition upon thermal cycling, we comparatively study the origin of the gap opening in the insulating VO 2 phases. By x-ray absorptionmore » and optical spectroscopy, we find that the shift of unoccupied t 2g orbitals away from the Fermi level is a common feature, which plays an important role for the insulating behavior in VO 2 polymorphs. The distinct splitting of the half-filled t 2g orbital is observed only in the M1 phase, widening the bandgap up to ~0.6 eV. Our approach of comparing all three insulating VO 2 phases provides insight into a better understanding of the electronic structure and the origin of the insulating gap in VO 2.« less

  10. Vacancy-oxygen defects in p-type Si1-xGex

    NASA Astrophysics Data System (ADS)

    Sgourou, E. N.; Londos, C. A.; Chroneos, A.

    2014-10-01

    Oxygen-vacancy defects and, in particular, the VO pairs (known as A-centers) are common defects in silicon (Si) with a deleterious impact upon its properties. Although oxygen-vacancy defects have been extensively studied in Si there is far less information about their properties in p-type doped silicon germanium (Si1-xGex). Here, we use Fourier transform infrared spectroscopy to determine the production and evolution of oxygen-vacancy defects in p-type Si1-xGex. It was determined that the increase of Ge content affects the production and the annealing behavior of the VO defect as well as its conversion to the VO2 defect. In particular, both the VO production and the VO annealing temperature are reduced with the increase of Ge. The conversion ratio [VO2]/[VO] also decreases with the increase of x, although the ratios [VO3]/[VO2] and [VO4]/[VO3] show a tendency to increase for larger Ge contents. The results are discussed in view of recent experimental and theoretical studies in Si and Si1-xGex.

  11. Oxygen uptake and blood metabolic responses to a 400-m run.

    PubMed

    Hanon, Christine; Lepretre, Pierre-Marie; Bishop, David; Thomas, Claire

    2010-05-01

    This study aimed to investigate the oxygen uptake and metabolic responses during a 400-m run reproducing the pacing strategy used in competition. A portable gas analyser was used to measure the oxygen uptake (VO2) of ten specifically trained runners racing on an outdoor track. The tests included (1) an incremental test to determine maximal VO2 (VO2max) and the velocity associated with VO2(max) (v - VO2max), (2) a maximal 400-m (400T) and 3) a 300-m running test (300T) reproducing the exact pacing pattern of the 400T. Blood lactate, bicarbonate concentrations [HCO3(-)], pH and arterial oxygen saturation were analysed at rest and 1, 4, 7, 10 min after the end of the 400 and 300T. The peak VO2 recorded during the 400T corresponded to 93.9 +/- 3.9% of VO2max and was reached at 24.4 +/- 3.2 s (192 +/- 22 m). A significant decrease in VO2 (P < 0.05) was observed in all subjects during the last 100 m, although the velocity did not decrease below v - VO2max. The VO2 in the last 5 s was correlated with the pH (r = 0.86, P < 0.0005) and [HCO3(-)] (r = 0.70, P < 0.05) measured at the end of 300T. Additionally, the velocity decrease observed in the last 100 m was inversely correlated with [HCO3(-)] and pH at 300T (r = -0.83, P < 0.001, r = -0.69, P < 0.05, respectively). These track running data demonstrate that acidosis at 300 m was related to both the VO2 response and the velocity decrease during the final 100 m of a 400-m run.

  12. Estimation of the rate of oxygen consumption of the common eider duck (Somateria mollissima), with some measurements of heart rate during voluntary dives.

    PubMed

    Hawkins, P A; Butler, P J; Woakes, A J; Speakman, J R

    2000-09-01

    The relationship between heart rate (f(H)) and rate of oxygen consumption (V(O2)) was established for a marine diving bird, the common eider duck (Somateria mollissima), during steady-state swimming and running exercise. Both variables increased exponentially with speed during swimming and in a linear fashion during running. Eleven linear regressions of V(O2) (ml kg(-1 )min(-1)) on f(H) (beats min(-1)) were obtained: five by swimming and six by running the birds. The common regression was described by V(O2)=10.1 + 0.15f(H) (r(2)=0.46, N=272, P<0.0001). The accuracy of this relationship for predicting mean V(O2) was determined for a group of six birds by recording f(H) continuously over a 2-day period and comparing estimated V(O2) obtained using the common regression with (i) V(O2) estimated using the doubly labelled water technique (DLW) and (ii) V(O2) measured using respirometry. A two-pool model produced the most accurate estimated V(O2) using DLW. Because of individual variability within mean values of V(O2) estimated using both techniques, there was no significant difference between mean V(O2) estimated using f(H) or DLW and measured V(O2) values (P>0.2), although individual errors were substantially less when f(H) was used rather than DLW to estimate V(O2). Both techniques are, however, only suitable for estimating mean V(O2) for a group of animals, not for individuals. Heart rate and behaviour were monitored during a bout of 63 voluntary dives by one female bird in an indoor tank 1.7 m deep. Tachycardia occurred both in anticipation of and following each dive. Heart rate decreased before submersion but was above resting values for the whole of the dive cycle. Mean f(H) at mean dive duration was significantly greater than f(H) while swimming at maximum sustainable surface speeds. Heart rate was used to estimate mean V(O2) during the dive cycle and to predict aerobic dive limit (ADL) for shallow dives.

  13. Core-shell VO2@TiO2 nanorods that combine thermochromic and photocatalytic properties for application as energy-saving smart coatings

    PubMed Central

    Li, Yamei; Ji, Shidong; Gao, Yanfeng; Luo, Hongjie; Kanehira, Minoru

    2013-01-01

    Vanadium dioxide (VO2) is a Mott phase transition compound that can be applied as a thermochromic smart material for energy saving and comfort, and titanium dioxide (TiO2) is a well-known photocatalyst for self-cleaning coatings. In this paper, we report a VO2@TiO2 core-shell structure, in which the VO2 nanorod core exhibits a remarkable modulation ability for solar infrared light, and the TiO2 anatase shell exhibits significant photocatalytic degradation of organic dye. In addition, the TiO2 overcoating not only increased the luminous transmittance of VO2 based on an antireflection effect, but also modified the intrinsic colour of VO2 films from yellow to light blue. The TiO2 also enhanced the chemical stability of VO2 against oxidation. This is the first report of such a single nanoparticle structure with both thermochromic and photocatalytic properties that offer significant potential for creating a multifunctional smart coating. PMID:23546301

  14. Core-shell VO2@TiO2 nanorods that combine thermochromic and photocatalytic properties for application as energy-saving smart coatings.

    PubMed

    Li, Yamei; Ji, Shidong; Gao, Yanfeng; Luo, Hongjie; Kanehira, Minoru

    2013-01-01

    Vanadium dioxide (VO2) is a Mott phase transition compound that can be applied as a thermochromic smart material for energy saving and comfort, and titanium dioxide (TiO2) is a well-known photocatalyst for self-cleaning coatings. In this paper, we report a VO2@TiO2 core-shell structure, in which the VO2 nanorod core exhibits a remarkable modulation ability for solar infrared light, and the TiO2 anatase shell exhibits significant photocatalytic degradation of organic dye. In addition, the TiO2 overcoating not only increased the luminous transmittance of VO2 based on an antireflection effect, but also modified the intrinsic colour of VO2 films from yellow to light blue. The TiO2 also enhanced the chemical stability of VO2 against oxidation. This is the first report of such a single nanoparticle structure with both thermochromic and photocatalytic properties that offer significant potential for creating a multifunctional smart coating.

  15. Characteristics of exercise training interventions to improve cardiorespiratory fitness after stroke: a systematic review with meta-analysis.

    PubMed

    Marsden, Dianne L; Dunn, Ashlee; Callister, Robin; Levi, Christopher R; Spratt, Neil J

    2013-01-01

    Cardiorespiratory fitness is low after stroke. Improving fitness has the potential to improve function and reduce secondary cardiovascular events. . This review with meta-analysis aims to identify characteristics and determine the effectiveness of interventions to improve cardiorespiratory fitness after stroke. A systematic search and review with meta-analysis was undertaken. Key inclusion criteria were the following: peer-reviewed articles published in English, adult stroke survivors, an intervention with the potential to improve cardiorespiratory fitness, and peak oxygen consumption (VO2peak) assessed preintervention and postintervention via a progressive aerobic exercise test. From 3209 citations identified, 28 studies were included, reporting results for 920 participants. Studies typically included chronic, ambulant participants with mild to moderate deficits; used an aerobic or mixed (with an aerobic component) intervention; and prescribed 3 sessions per week for 30 to 60 minutes per session at a given intensity. Baseline VO2peak values were low (8-23 mL/kg/min). Meta-analysis of the 12 randomized controlled trials demonstrated overall improvements in VO2peak of 2.27 (95% confidence interval = 1.58, 2.95) mL/kg/min postintervention. A similar 10% to 15% improvement occurred with both aerobic and mixed interventions and in shorter (≤ 3 months) and longer (>3 months) length programs. Only 1 study calculated total dose received and only 1 included long-term follow-up. The results demonstrate that interventions with an aerobic component can improve cardiorespiratory fitness poststroke. Further investigation is required to determine effectiveness in those with greater impairment and comorbidities, optimal timing and dose of intervention, whether improvements can be maintained in the longer term, and whether improved fitness results in better function and reduced risk of subsequent cardiovascular events.

  16. Electric field induced metal-insulator transition in VO2 thin film based on FTO/VO2/FTO structure

    NASA Astrophysics Data System (ADS)

    Hao, Rulong; Li, Yi; Liu, Fei; Sun, Yao; Tang, Jiayin; Chen, Peizu; Jiang, Wei; Wu, Zhengyi; Xu, Tingting; Fang, Baoying

    2016-03-01

    A VO2 thin film has been prepared using a DC magnetron sputtering method and annealing on an F-doped SnO2 (FTO) conductive glass substrate. The FTO/VO2/FTO structure was fabricated using photolithography and a chemical etching process. The temperature dependence of the I-V hysteresis loop for the FTO/VO2/FTO structure has been analyzed. The threshold voltage decreases with increasing temperature, with a value of 9.2 V at 20 °C. The maximum transmission modulation value of the FTO/VO2/FTO structure is 31.4% under various temperatures and voltages. Optical modulation can be realized in the structure by applying an electric field.

  17. Simulated swimming: a useful tool for evaluation the VO2 max of swimmers in the laboratory.

    PubMed Central

    Kimura, Y; Yeater, R A; Martin, R B

    1990-01-01

    This study was designed to develop a simulated swimming exercise (SS) so that peak VO2 would be assessed on swimmers in a laboratory setting. The subjects assumed a prone position on an incline bench and performed arm cranking on a Monark Rehab Trainer while performing a flutter kick against tension supplied by elastic cords. The SS test was compared to four peak VO2 tests: treadmill running (RN), tethered swimming (TW), bicycle ergometry (B), and arm cranking (AC). Eleven male varsity swimmers underwent each of the five VO2 max tests, and maximal cardiorespiratory indicators (HR, VE, VO2, O2 pulse, and RQ) were measured. The percentage of peak VO2 obtained during SS was compared to RN, TW, B, and AC. The SS test achieved 78 percent of RN, 91 percent of TW, 81 percent of B, and 124 percent of AC. There were no significant differences in VO2 in ml/kg.min between SS and TW. As expected, RN and B were significantly higher, while AC was lower. Ten subjects performed the SS test twice on two separate days within one week. The reliability of VO2 max in ml/kg.min was 0.95. the validity of VO2 max in ml/kg.min in the SS test vs. RN was 0.68. The SS test is reliable and can be used as effectively as TW to assess the VO2 max of swimmers in a laboratory setting. PMID:2078808

  18. Decoding and reconstructing color from responses in human visual cortex.

    PubMed

    Brouwer, Gijs Joost; Heeger, David J

    2009-11-04

    How is color represented by spatially distributed patterns of activity in visual cortex? Functional magnetic resonance imaging responses to several stimulus colors were analyzed with multivariate techniques: conventional pattern classification, a forward model of idealized color tuning, and principal component analysis (PCA). Stimulus color was accurately decoded from activity in V1, V2, V3, V4, and VO1 but not LO1, LO2, V3A/B, or MT+. The conventional classifier and forward model yielded similar accuracies, but the forward model (unlike the classifier) also reliably reconstructed novel stimulus colors not used to train (specify parameters of) the model. The mean responses, averaged across voxels in each visual area, were not reliably distinguishable for the different stimulus colors. Hence, each stimulus color was associated with a unique spatially distributed pattern of activity, presumably reflecting the color selectivity of cortical neurons. Using PCA, a color space was derived from the covariation, across voxels, in the responses to different colors. In V4 and VO1, the first two principal component scores (main source of variation) of the responses revealed a progression through perceptual color space, with perceptually similar colors evoking the most similar responses. This was not the case for any of the other visual cortical areas, including V1, although decoding was most accurate in V1. This dissociation implies a transformation from the color representation in V1 to reflect perceptual color space in V4 and VO1.

  19. Localized surface plasmon resonance modulation of totally encapsulated VO2/Au/VO2 composite structure

    NASA Astrophysics Data System (ADS)

    Liang, Jiran; Guo, Jinbang; Zhao, Yirui; Zhang, Ying; Su, Tianyu

    2018-07-01

    We design and fabricate a totally encapsulated VO2/Au/VO2 composite structure which is aimed to improve the tunability of the localized surface plasmon resonance (LSPR) peak. In this work, the structure will ensure all the Au NPs’ resonant electric field area is filled with VO2. The modulation range of the totally encapsulated structure is larger than that of the semi-coated structure. To further improve the modulation range, we also explore the VO2 thickness dependence of the structure’s LSPR modulation. With the increase of the top layer VO2 thin film thickness, the modulation range becomes larger. When the thickness is about 80 nm, the absorption peak achieves a largest shift of 112 nm. FDTD solution and equivalent model of series capacitor are used to explain the phenomenon. These results will contribute to the area of metamaterial electromagnetic wave absorber and other fields.

  20. Enhanced electrochemical performance of orientated VO2(B) raft-like nanobelt arrays through direct lithiation for lithium ion batteries.

    PubMed

    Liu, Liang; Liu, Qiang; Zhao, Wen; Li, Guochun; Wang, Limei; Shi, Weidong; Chen, Long

    2017-02-10

    Lithiation modification of VO 2 (B) has been carried out by a facile hydrothermal process, and the compact and locally ordered VO 2 (B) raft-like nanobelt arrays have been prepared. The synthesis route provides a new approach to elaborate a VO 2 (B) nanostructure under a mild environment condition. It is found that the growth mechanism of VO 2 (B) raft-like nanobelt arrays is different from the traditional nucleation-growth process. A novel chemical lithiating-exfoliating-splitting model is proposed. Compared with the bulk counterpart, the lithiated VO 2 (B) raft-like nanobelt arrays as cathodes exhibit a higher discharge capacity and an enhanced high-rate performance owing to their increased structural anisotropy and decreased polarization. This work indicates that VO 2 (B) raft-like nanobelt arrays have great potential applications as cathode materials for lithium ion batteries.

  1. Enhanced electrochemical performance of orientated VO2(B) raft-like nanobelt arrays through direct lithiation for lithium ion batteries

    NASA Astrophysics Data System (ADS)

    Liu, Liang; Liu, Qiang; Zhao, Wen; Li, Guochun; Wang, Limei; Shi, Weidong; Chen, Long

    2017-02-01

    Lithiation modification of VO2(B) has been carried out by a facile hydrothermal process, and the compact and locally ordered VO2(B) raft-like nanobelt arrays have been prepared. The synthesis route provides a new approach to elaborate a VO2(B) nanostructure under a mild environment condition. It is found that the growth mechanism of VO2(B) raft-like nanobelt arrays is different from the traditional nucleation-growth process. A novel chemical lithiating-exfoliating-splitting model is proposed. Compared with the bulk counterpart, the lithiated VO2(B) raft-like nanobelt arrays as cathodes exhibit a higher discharge capacity and an enhanced high-rate performance owing to their increased structural anisotropy and decreased polarization. This work indicates that VO2(B) raft-like nanobelt arrays have great potential applications as cathode materials for lithium ion batteries.

  2. Localized surface plasmon resonance modulation of totally encapsulated VO2/Au/VO2 composite structure.

    PubMed

    Liang, Jiran; Guo, Jinbang; Zhao, Yirui; Zhang, Ying; Su, Tianyu

    2018-07-06

    We design and fabricate a totally encapsulated VO 2 /Au/VO 2 composite structure which is aimed to improve the tunability of the localized surface plasmon resonance (LSPR) peak. In this work, the structure will ensure all the Au NPs' resonant electric field area is filled with VO 2 . The modulation range of the totally encapsulated structure is larger than that of the semi-coated structure. To further improve the modulation range, we also explore the VO 2 thickness dependence of the structure's LSPR modulation. With the increase of the top layer VO 2 thin film thickness, the modulation range becomes larger. When the thickness is about 80 nm, the absorption peak achieves a largest shift of 112 nm. FDTD solution and equivalent model of series capacitor are used to explain the phenomenon. These results will contribute to the area of metamaterial electromagnetic wave absorber and other fields.

  3. Transparent optically vanadium dioxide thermochromic smart film fabricated via electrospinning technique

    NASA Astrophysics Data System (ADS)

    Lu, Yuan; Xiao, Xiudi; Cao, Ziyi; Zhan, Yongjun; Cheng, Haoliang; Xu, Gang

    2017-12-01

    The monoclinic phase vanadium dioxide VO2 (M) based transparent thermochromic smart films were firstly fabricated through heat treatment of opaque VO2-based composite nanofibrous mats, which were deposited on the glass substrate via electrospinning technique. Noteworthily, the anti-oxidation property of VO2 smart film was improved due to inner distribution of VO2 in the polymethylmethacrylate (PMMA) nanofibers, and the composite mats having water contact angle of 165° determined itself good superhydrophobic property. Besides, PMMA nanofibrous mats with different polymer concentrations demonstrated changeable morphology and fiber diameter. The VO2 nanoparticles having diameter of 30-50 nm gathered and exhibited ellipse-like or belt-like structure. Additionally, the solar modulation ability of PMMA-VO2 composite smart film was 6.88% according to UV-Vis-NIR spectra. The research offered a new notion for fabricating transparent VO2 thermochromic material.

  4. Effect of W addition on the electrical switching of VO{sub 2} thin films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rajeswaran, Bharathi, E-mail: rajeswaran.bharathi@gmail.com, E-mail: rbharathi@mrc.iisc.ernet.in; Umarji, Arun M.

    2016-03-15

    Vanadium Oxide has been a frontrunner in the field of oxide electronics because of its metal-insulator transition (MIT). The interplay of different structures of VO{sub 2} has played a crucial role in deciding the magnitude of the first order MIT. Substitution doping has been found to introduce different polymorphs of VO{sub 2}. Hence the role of substitution doping in stabilizing the competing phases of VO{sub 2} in the thin film form remains underexplored. Consequently there have been reports both discounting and approving such a stabilization of competing phases in VO{sub 2}. It is reported in the literature that the bandwidthmore » of the hysteresis and transition temperature of VO{sub 2} can be tuned by substitutional doping of VO{sub 2} with W. In this work, we have adopted a novel technique called, Ultrasonic Nebulized Spray Pyrolysis of Aqueous Combustion Mixture (UNSPACM) to deposit VO{sub 2} and W- doped VO{sub 2} as thin films. XRD and Raman spectroscopy were used to investigate the role of tungsten on the structure of VO{sub 2} thin films. Morphology of the thin films was found to be consisting of globular and porous nanoparticles of size ∼ 20 nm. Transition temperature decreased with the addition of W. We found that for 2.0 at % W doping in VO{sub 2}, the transition temperature has reduced from 68 {sup o} C to 25 {sup o} C. It is noted that W-doping in the process of reducing the transition temperature, alters the local structure and also increases room temperature carrier concentration.« less

  5. Aerobic Fitness Level Typical of Elite Athletes is not Associated With Even Faster VO2 Kinetics During Cycling Exercise

    PubMed Central

    Figueira, Tiago R.; Caputo, Fabrizio; Machado, Carlos E.P.; Denadai, Benedito S.

    2008-01-01

    The aim of this study was to address the question if the VO2 kinetics is further improved as the aerobic training status increases from trained to elite level athletes. Maximal oxygen uptake (VO2max), work-rate associated to VO2max (IVO2max) and VO2 kinetics of moderate (Mod) and maximal exercise (Max) were determined in fifty- five subjects. Then, they were assigned into three groups: low (LF), intermediate (IF) and high (HF) aerobic fitness level. In average, the VO2max of LF, IF and HF groups were, respectively, 36.0 ± 3.1, 51.1 ± 4.5 and 68.1 ± 3.9 ml·kg·min-1 (p ≤ 0.05 among each other). VO2 kinetics mean response time of both exercise intensities were significantly faster (p ≤ 0.05) in HF (Mod, 27.5 ± 5.5 s; Max, 32.6 ± 8.3 s) and IF (Mod, 25.0 ± 3.1 s; Max, 42.6 ± 10.4 s) when compared to LF (Mod, 35.7 ± 7.9 s; Max: 57.8 ± 17.8 s). We can conclude that VO2 kinetics is improved as the fitness level is increased from low to intermediate but not further improved as the aerobic fitness level increases from intermediate to high. Key points Currently, it is reasonable to believe that the rate-limiting step of VO2 kinetics depends on exercise intensity. The well known physiological adaptations induced by endurance training are likely the most extreme means to overcome rate-limiting steps determining VO2 kinetics across exercise intensities. However, exercise adaptation leading individuals to the high-end of aerobic fitness level range (VO2max > 65 ml.kg.min-1) is not able to further improve VO2 kinetics during both, moderate and maximal intensity exercise. PMID:24150145

  6. Physiologic responses during indoor cycling.

    PubMed

    Battista, Rebecca A; Foster, Carl; Andrew, Jessica; Wright, Glenn; Lucia, Alejandro; Porcari, John P

    2008-07-01

    During the last decade, there has been active interest in indoor cycling (e.g., spinning) as a method of choreographed group exercise. Recent studies have suggested that exercise intensity during indoor cycling may be quite high and may transiently exceed Vo2max. This study sought to confirm these findings, as the apparent high intensity of indoor cycling has implications for both the efficacy and the risk of indoor cycling as an exercise method. Twenty healthy female students performed an incremental exercise test to define Vo2max and performed 2 videotaped indoor exercise classes lasting 45 minutes and 35 minutes. Vo2, heart rate (HR), and rating of perceived exertion (RPE) were measured during the indoor cycling classes, with Vo2 data integrated in 30-second intervals. The mean %Vo2max during the indoor cycling classes was modest (74 +/- 14% Vo2max and 66 +/- 14%Vo2max, respectively). However, 52% and 35% of the time during the 45- and 35-minute classes was spent at intensities greater than the ventilatory threshold (VT). The HR response indicated that 35% and 38% of the session time was above the HR associated with VT. In 10 of the 40 exercise sessions, there were segments in which the momentary Vo2 exceeded Vo2max observed during incremental testing, and the cumulative time with exercise intensity greater than Vo2max ranged from 0.5 to 14.0 minutes. It can be concluded that although the intensity of indoor cycling in healthy, physically active women is moderate, there are frequent observations of transient values of Vo2 exceeding Vo2max, and a substantial portion of the exercise bouts at intensities greater than VT. As such, the data suggest that indoor cycling must be considered a high-intensity exercise mode of exercise training, which has implications for both efficacy and risk.

  7. Prognostic impact of peakVO2-changes in stable CHF on chronic beta-blocker treatment.

    PubMed

    Frankenstein, L; Nelles, M; Hallerbach, M; Dukic, D; Fluegel, A; Schellberg, D; Katus, H A; Remppis, A; Zugck, C

    2007-11-15

    Peak oxygen uptake (pVO2) is used for risk stratification in chronic heart failure (CHF), but little is known about the prognostic impact of pVO2-changes in patients on chronic beta-blocker (BBL) therapy. We therefore prospectively evaluated individual pVO2-changes at a 6-month interval in patients all receiving BBL. 194 patients with stable CHF on stable medication were included (V1) and underwent clinical evaluation and exercise testing. Testing was repeated (V2) at 5.7+/-1.5 months after V1 and patients were followed >12 months after V2. Death or hospitalisation due to cardiac reasons was the predefined EP (EPP, end-point positive; n=62; EPN, end-point negative; n=113). Initial characteristics did not differ between EPP and EPN. Multivariate cox regression analysis revealed that change of pVO2 (EPP: -0.6+/-2.6 ml/kg min; EPN: +2.5+/-3.3 ml/kg min; p<0.001) was independent to pVO2, LVEF, NTproBNP and NYHA at V2 for prediction of the combined end-point during follow-up. An increase of pVO2 by 10% was identified as an adequate cut-off value for risk stratification and ROC-analysis showed the significant incremental prognostic value of the determination of pVO2 changes in combination with pVO2. Serial measurements of pVO2 yield additional information for risk stratification in clinically homogenous CHF patients receiving BBL. This is the first study demonstrating this fact within a narrow predefined interval with all patients on BBL.

  8. Switchable vanadium dioxide (VO2) metamaterials fabricated from tungsten doped vanadia-based colloidal nanocrystals

    NASA Astrophysics Data System (ADS)

    Paik, Taejong; Hong, Sung-Hoon; Gordon, Thomas; Gaulding, Ashley; Kagan, Cherie; Murray, Christopher

    2013-03-01

    We report the fabrication of thermochromic VO2-based metamaterials using solution-processable colloidal nanocrystals. Vanadium-based nanoparticles are prepared through a non-hydrolytic reaction, resulting in stable colloidal dispersions in solution. Thermochromic nanocrystalline VO2 thin-films are prepared via rapid thermal annealing of colloidal nanoparticles coated on a variety of substrates. Nanostructured VO2 can be patterned over large areas by nanoimprint lithography. Precise control of tungsten (W) doping concentration in colloidal nanoparticles enables tuning of the phase transition temperature of the nanocrystalline VO2 thin-films. W-doped VO2 films display a sharp temperature dependent phase transition, similar to the undoped VO2 film, but at lower temperatures tunable with the doping level. By sequential coating of doped VO2 with different doping concentrations, we fabricate ?smart? multi-layered VO2 films displaying multiple phase transition temperatures within a single structure, allowing for dynamic modulation of the metal-dielectric layered structure. The optical properties programmed into the layered structure are switchable with temperature, which provides additional degrees of freedom to design tunable optical metamaterials. This work is supported by the US Office of Naval Research Multidisciplinary University Research Initiative (MURI) program grant number ONR-N00014-10-1-0942.

  9. Separation of β-amyloid binding and white matter uptake of 18F-flutemetamol using spectral analysis

    PubMed Central

    Heurling, Kerstin; Buckley, Christopher; Vandenberghe, Rik; Laere, Koen Van; Lubberink, Mark

    2015-01-01

    The kinetic components of the β-amyloid ligand 18F-flutemetamol binding in grey and white matter were investigated through spectral analysis, and a method developed for creation of parametric images separating grey and white matter uptake. Tracer uptake in grey and white matter and cerebellar cortex was analyzed through spectral analysis in six subjects, with (n=4) or without (n=2) apparent β-amyloid deposition, having undergone dynamic 18F-flutemetamol scanning with arterial blood sampling. The spectra were divided into three components: slow, intermediate and fast basis function rates. The contribution of each of the components to total volume of distribution (VT) was assessed for different tissue types. The slow component dominated in white matter (average 90%), had a higher contribution to grey matter VT in subjects with β-amyloid deposition (average 44%) than without (average 6%) and was absent in cerebellar cortex, attributing the slow component of 18F-flutemetamol uptake in grey matter to β-amyloid binding. Parametric images of voxel-based spectral analysis were created for VT, the slow component and images segmented based on the slow component contribution; confirming that grey matter and white matter uptake can be discriminated on voxel-level using a threshold for the contribution from the slow component to VT. PMID:26550542

  10. Structures, physicochemical and cytoprotective properties of new oxidovanadium(IV) complexes -[VO(mIDA)(dmbipy)]·1.5H2O and [VO(IDA)(dmbipy)]·2H2O

    NASA Astrophysics Data System (ADS)

    Drzeżdżon, Joanna; Jacewicz, Dagmara; Wyrzykowski, Dariusz; Inkielewicz-Stępniak, Iwona; Sikorski, Artur; Tesmar, Aleksandra; Chmurzyński, Lech

    2017-09-01

    New oxidovanadium(IV) complexes with a modification of the ligand in the VO2+ coordination sphere were synthesized. [VO(mIDA)(dmbipy)]•1.5H2O and [VO(IDA)(dmbipy)]•2H2O were obtained as dark green crystals and grey-green powder, respectively (mIDA = N-methyliminodiacetic anion, IDA = iminodiacetic anion, dmbipy = 4,4‧-dimethoxy-2,2‧-dipyridyl). The crystal structure of [VO(mIDA)(dmbipy)]·1.5H2O has been determined by the X-ray diffraction method. The studies of structure of [VO(mIDA)(dmbipy)]•1.5H2O have shown that this compound occurs in the crystal as two rotational conformers. Furthermore, the stability constants of [VO(mIDA)(dmbipy)]•1.5H2O and [VO(IDA)(dmbipy)]•2H2O complexes in aqueous solutions were studied by using the potentiometric titration method and, consequently, determined using the Hyperquad2008 program. Moreover, the title complexes were investigated as antioxidant substances. The impact of the structure modification in the VO2+ complexes on the radical scavenging activity has been studied. The ability to scavenge the superoxide radical by two complexes - [VO(mIDA)(dmbipy)]·1.5H2O and [VO(IDA)(dmbipy)]·2H2O was studied by cyclic voltammetry (CV) and nitrobluetetrazolium (NBT) methods. The title complexes were also examined by the spectrophotometric method as scavengers of neutral organic radical - 1,1-diphenyl-2-picrylhydrazyl (DPPH•) and radical cation - 2,2'-azinobis-(3-ethylbenzothiazoline)-6-sulfonic acid (ABTS•+). Furthermore, the biological properties of two oxidovanadium(IV) complexes were investigated in relation to its cytoprotective properties by the MTT and LDH tests based on the hippocampal HT22 neuronal cell line during the oxidative damage induced by hydrogen peroxide. Finally, the results presented in this paper have shown that the both new oxidovanadium(IV) complexes with the 4,4‧-dimethoxy-2,2‧-dipyridyl ligand can be treated as the cytoprotective substances.

  11. Facile synthesis, phase transition, optical switching and oxidation resistance properties of belt-like VO{sub 2}(A) and VO{sub 2}(M) with a rectangular cross section

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Yifu; Huang, Yanfen; Zhang, Juecheng

    2012-08-15

    Highlights: ► Belt-like VO{sub 2}(A) with a rectangular cross section was synthesized. ► The formation mechanism of belt-like VO{sub 2}(A) was proposed. ► Belt-like VO{sub 2}(M) was prepared by the irreversible transformation of VO{sub 2}(A). ► VO{sub 2}(A) and VO{sub 2}(M) can be used as the optical switching materials. ► VO{sub 2}(A) and VO{sub 2}(M) have good oxidation resistance below 400 °C in air. -- Abstract: Belt-like VO{sub 2}(A) with a rectangular cross section (VA-RCS) was successfully synthesized using V{sub 2}O{sub 5}, H{sub 2}C{sub 2}O{sub 4}·2H{sub 2}O and H{sub 2}O as the starting materials by a facile hydrothermal approach. Somemore » synthetic parameters, such as, the reaction time, reaction temperature and concentration of H{sub 2}C{sub 2}O{sub 4}·2H{sub 2}O, were systematically investigated to control the fabrication of belt-like VA-RCS. The formation mechanism of belt-like VA-RCS was proposed. Subsequently, belt-like VO{sub 2}(M) with a rectangular cross section (VM-RCS) was prepared by the irreversible transformation of VA-RCS at 700 °C for 2 h under the inert atmosphere. The phase transition temperature (T{sub c}) of VA-RCS and VM-RCS was evaluated by DSC test. The optical switching properties of VA-RCS and VM-RCS were studied by the variable-temperature infrared spectra, and it was found that the as-obtained VA-RCS and VM-RCS could be used as the optical switching materials. Furthermore, the oxidation resistance properties of VA-RCS and VM-RCS were investigated by TGA, indicating that they have good thermal stability and oxidation resistance below 400 °C in air.« less

  12. Chemical bond parameters and photoluminescence of a natural-white-light Ca{sub 9}La(VO{sub 4}){sub 7}:Tm{sup 3+},Eu{sup 3+} with one O{sup 2−}→V{sup 5+} charge transfer and dual f-f transition emission centers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Ling; Liu, Xiao Guang; Department of Physics, Pukyong National University, Busan 608-737

    2015-01-15

    The relationship between the photoluminescence properties and the crystal structure of undoped, Eu{sup 3+} or/ and Tm{sup 3+} singly or codoped Ca{sub 9}La(VO{sub 4}){sub 7} (CLaVO) samples was discussed. Under the excitation of UV light, CLaVO:Tm{sup 3+}, CLaVO, and CLaVO:Eu{sup 3+} exhibit the characteristic emissions of Tm{sup 3+} ({sup 1}G{sub 4}→{sup 3}H{sub 6}, blue), O{sup 2−}→V{sup 5+} charge transfer (CT), and Eu{sup 3+} ({sup 5}D{sub 0}→{sup 7}F{sub 2}, red), respectively. By adjusting the doping concentration of Tm{sup 3+} and Eu{sup 3+} ions in CLaVO, a natural white emission in a single composition with the color temperature at 6181 K wasmore » obtained. Based on the dielectric theory of complex crystal, the chemical bond parameters of La-O and V-O bonds were quantitatively calculated. The standard deviation of environmental factor of every bond (EFSD), which can be expressed as σ(h{sub e{sub i}})=√((1/N)∑{sub i=1}{sup N}(h{sub e{sub i}}−μ){sup 2}) (h{sub e{sub i}}=(f{sub c{sub i}}α{sub b{sub i}}){sup 1/2}Q{sub B{sub i}} and μ=(1/N)∑{sub i=1}{sup N}h{sub e{sub i}}), was proposed to quantitatively express the distortion degree of VO{sub 4}{sup 3−} from that of an ideal tetrahedron. The maximum change of EFSD comes from the [VO{sub 4}]{sup −} tetrahedra in CLaVO sample by comparison with that of EFSD of isostructural Ca{sub 9}Gd(VO{sub 4}){sub 7}. This is possible the key reason that the undoped CLaVO sample has self-activated emission while the self-activated emission of its isostructural Ca{sub 9}Gd(VO{sub 4}){sub 7} sample cannot be found. The quantitative calculation also demonstrated that the broad excitation bands at 319 nm in CLaVO:Tm and at 335 nm in CLaVO:Eu were due to the O-V2 and O-V3 (overlap with O-V2) CT, not the CT energy of O{sup 2−}-Eu1{sup 3+} (O{sup 2−}-Tm1{sup 3+}), O{sup 2−}-Eu2{sup 3+} (O{sup 2−}-Tm2{sup 3+}), and O{sup 2−}-Eu3{sup 3+} (O{sup 2−}-Tm3{sup 3+}). The environmental factors surrounding the atoms V1, V2 and V3 were calculated to be 1.577, 1.6379 and 1.7554, respectively. It can be demonstrated that the excitation spectra at 319 nm for CLaVO:Tm and 335 nm for CLaVO:Eu came from the O-V2 and O-V3 CT, respectively. - Graphical abstracts: The relationship between the photoluminescence properties and the crystal structure of undoped, Eu{sup 3+} or/ and Tm{sup 3+} singly or codoped Ca{sub 9}La(VO{sub 4}){sub 7} (CLaVO) samples was discussed experimentally and theoretically. - Highlights: ●The photoluminescence properties of Ca{sub 9}La(VO{sub 4}){sub 7}:Eu, Tm were measured. ●The tunable color including white emission can be obtained. ●The important chemical bond parameters of O-V were calculated quantitatively. ●The standard deviation of environmental factor of every bond was proposed. ●The theoretical analysis of the self-activated emission for Ca{sub 9}La(VO{sub 4}){sub 7} was given.« less

  13. Orientation of Vanadium Dioxide Grains on Various Substrates

    NASA Astrophysics Data System (ADS)

    Rivera, Felipe; Davis, Robert; Vanfleet, Richard

    2010-10-01

    Crystalline vanadium dioxide VO2 experiences a fast and reversible semiconductor-to-metal structural phase transition near 68^oC. The changes exhibited during this phase transition comprise a well known change in resistivity of several orders of magnitude, as well as a significant drop in optical transmittance in the infrared. Due to the changes in these optical and electronic properties, vanadium dioxide shows promise as a material to be used in many applications ranging from thermochromic window coatings to optoelectronic devices. However, since there is a structural component to the phase transition of VO2, it is of interest to study the orientation of the crystalline grains deposited. Substrates such as glass, SiO2, Sapphire, and TiO2 have been used for the deposition of this material. We used orientation imaging microscopy to study and characterize the orientation of the grains deposited on several of these substrates. Here we present results on this study.

  14. Readout concepts for the suppression of the slow component of BaF2 for the upgrade of the TAPS spectrometer at ELSA

    NASA Astrophysics Data System (ADS)

    Diehl, Stefan; Novotny, Rainer W.; Wohlfahrt, Benjamin; Beck, Reinhard

    2015-02-01

    For the measurement at extremely high interaction rates with fast scintillators, pile-up of consecutive events is a limiting factor. With a decay time of 600 ps of the fast crossluminescence component, Barium Fluoride (BaF2) is one of the fastest inorganic scintillators known today. However, the dominating slow component with a 3 orders of magnitude longer decay time of 630 ns limits the rate capability. To circumvent this limit, different approaches have been made in the past. The slow component can be suppressed for example by doping the crystals with rare earth ions like La3+. The paper will give an overview over the various concepts investigated in the past and present the suppression via optical band pass filters. This method has been chosen for the upgrade of the BaF2 crystals in the most forward region of the TAPS-spectrometer at ELSA in Bonn. It allows to reuse the existing crystals and to achieve a high degree of suppression of the slow component. The focus of the paper will be on the selection of the filters, the achievable rate capability and the energy resolution of the fast component.

  15. Appropriateness of the metabolic equivalent (MET) as an estimate of exercise intensity for post-myocardial infarction patients.

    PubMed

    Woolf-May, Kate; Meadows, Steve

    2016-01-01

    To explore: (1) whether during exercise metabolic equivalents (METs) appropriately indicate the intensity and/or metabolic cost for post-myocardial infarction (MI) males and (2) whether post-exercise VO 2 parameters provide insight into the intensity and/or metabolic cost of the prior exercise. 15 male phase-IV post-MIs (64.4±6.5 years) and 16 apparently healthy males (63.0±6.4 years) participated. Participants performed a graded cycle ergometer test (CET) of 50, 75 and 100 W, followed by 10 min active recovery (at 50 W) and 22 min seated recovery. Participants' heart rate (HR, bpm), expired air parameters and ratings of perceived exertion (exercise only) were measured. General linear model analysis showed throughout significantly lower HR values in post-MI participants that were related to β-blocker medication ( F (2,5) =18.47, p<0.01), with significantly higher VCO 2 /VO 2 ( F (2,5) =11.25, p<0.001) and gross kcals/LO 2 /min ( F (2,5) =11.25, p<0.001). Analysis comparing lines of regression showed, during the CET: post-MI participants worked at higher percentage of their anaerobic threshold (%AT)/MET than controls ( F (2,90) =18.98, p<0.001), as well as during active recovery (100-50 W) ( F (2,56) =20.81, p<0.001); during seated recovery: GLM analysis showed significantly higher values of VCO 2 /VO 2 for post-MI participants compared with controls ( F (2,3) =21.48, p=0.001) as well as gross kcals/LO 2 /min ( F (2,3) =21.48, p=0.001). Since METs take no consideration of any anaerobic component, they failed to reflect the significantly greater anaerobic contribution during exercise per MET for phase-IV post-MI patients. Given the anaerobic component will be greater for those with more severe forms of cardiac disease, current METs should be used with caution when determining exercise intensity in any patient with cardiac disease.

  16. VO2max and ventilatory threshold of trained cyclists are not affected by 28-day L-arginine supplementation.

    PubMed

    Sunderland, Kyle L; Greer, Felicia; Morales, Jacobo

    2011-03-01

    The ergogenic effect of L-arginine on an endurance-trained population is not well studied. The few studies that have investigated L-arginine on this population have not been conducted in a laboratory setting or measured aerobic variables. The purpose of the current study is to determine if 28 days of L-arginine supplementation in trained male cyclists affects VO2max and ventilatory threshold (VT). Eighteen (18) endurance-trained male cyclists (mean ± SD, age: 36.3 ± 7.9 years; height: 182.4 ± 4.6 cm; and body mass: 79.5 ± 4.7 kg) performed a graded exercise test (GXT; 50 W + 25 W·min) before and after 28 days of supplementation with L-arginine (ARG; 2 × 6 g·d) or placebo (PLA; cornstarch). The GXT was conducted on the subject's own bicycle using the RacerMate CompuTrainer (Seattle, WA, USA). VO2 was continuously recorded using the ParvoMedics TrueOne 2400 metabolic cart (Salt Lake City, UT, USA) and VT was established by plotting the ventilatory equivalent for O2 (VE/VO2) and the ventilatory equivalent for CO2 (VE/VCO2) and identifying the point at which VE/VO2 increases with no substantial changes in VE/VCO2. L-arginine supplementation had no effect from initial VO2max (PL, 58.7 ± 7.1 ml·kg·min; ARG, 63.5 ± 7.3 ml·kg·min) to postsupplement VO2max (PL, 58.9 ± 6.0 ml·kg·min; ARG, 63.2 ± 7.2 ml·kg·min). Also, no effect was seen from initial VT (PL, 75.7 ± 4.6% VO2max; ARG, 76.0 ± 5.3% VO2max) to postsupplement VT (PL, 74.3 ± 8.1% VO2max; ARG, 74.2 ± 6.4% VO2max). These results indicate that L-arginine does not impact VO2max or VT in trained male cyclists.

  17. VO2 /TiN Plasmonic Thermochromic Smart Coatings for Room-Temperature Applications.

    PubMed

    Hao, Qi; Li, Wan; Xu, Huiyan; Wang, Jiawei; Yin, Yin; Wang, Huaiyu; Ma, Libo; Ma, Fei; Jiang, Xuchuan; Schmidt, Oliver G; Chu, Paul K

    2018-03-01

    Vanadium dioxide/titanium nitride (VO 2 /TiN) smart coatings are prepared by hybridizing thermochromic VO 2 with plasmonic TiN nanoparticles. The VO 2 /TiN coatings can control infrared (IR) radiation dynamically in accordance with the ambient temperature and illumination intensity. It blocks IR light under strong illumination at 28 °C but is IR transparent under weak irradiation conditions or at a low temperature of 20 °C. The VO 2 /TiN coatings exhibit a good integral visible transmittance of up to 51% and excellent IR switching efficiency of 48% at 2000 nm. These unique advantages make VO 2 /TiN promising as smart energy-saving windows. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. End-exercise ΔHHb/ΔVO2 and post-exercise local oxygen availability in relation to exercise intensity.

    PubMed

    Stöcker, F; Von Oldershausen, C; Paternoster, F K; Schulz, T; Oberhoffer, R

    2017-07-01

    Increased local blood supply is thought to be one of the mechanisms underlying oxidative adaptations to interval training regimes. The relationship of exercise intensity with local blood supply and oxygen availability has not been sufficiently evaluated yet. The aim of this study was to examine the effect of six different intensities (40-90% peak oxygen uptake, VO 2peak ) on relative changes in oxygenated, deoxygenated and total haemoglobin (ΔO 2 Hb, ΔHHb, ΔTHb) concentration after exercise as well as end-exercise ΔHHb/ΔVO 2 as a marker for microvascular O 2 distribution. Seventeen male subjects performed an experimental protocol consisting of 3 min cycling bouts at each exercise intensity in randomized order, separated by 5 min rests. ΔO 2 Hb and ΔHHb were monitored with near-infrared spectroscopy of the vastus lateralis muscle, and VO 2 was assessed. ΔHHb/ΔVO 2 increased significantly from 40% to 60% VO 2 peak and decreased from 60% to 90% VO 2 peak. Post-exercise ΔTHb and ΔO 2 Hb showed an overshoot in relation to pre-exercise values, which was equal after 40-60% VO 2peak and rose significantly thereafter. A plateau was reached following exercise at ≥80% VO 2peak . The results suggest that there is an increasing mismatch of local O 2 delivery and utilization during exercise up to 60% VO 2peak . This insufficient local O 2 distribution is progressively improved above that intensity. Further, exercise intensities of ≥80% VO 2peak induce highest local post-exercise O 2 availability. These effects are likely due to improved microvascular perfusion by enhanced vasodilation, which could be mediated by higher lactate production and the accompanying acidosis. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  19. Conformal Coating of a Phase Change Material on Ordered Plasmonic Nanorod Arrays for Broadband All-Optical Switching.

    PubMed

    Guo, Peijun; Weimer, Matthew S; Emery, Jonathan D; Diroll, Benjamin T; Chen, Xinqi; Hock, Adam S; Chang, Robert P H; Martinson, Alex B F; Schaller, Richard D

    2017-01-24

    Actively tunable optical transmission through artificial metamaterials holds great promise for next-generation nanophotonic devices and metasurfaces. Plasmonic nanostructures and phase change materials have been extensively studied to this end due to their respective strong interactions with light and tunable dielectric constants under external stimuli. Seamlessly integrating plasmonic components with phase change materials, as demonstrated in the present work, can facilitate phase change by plasmonically enabled light confinement and meanwhile make use of the high sensitivity of plasmon resonances to the variation of dielectric constant associated with the phase change. The hybrid platform here is composed of plasmonic indium-tin-oxide nanorod arrays (ITO-NRAs) conformally coated with an ultrathin layer of a prototypical phase change material, vanadium dioxide (VO 2 ), which enables all-optical modulation of the infrared as well as the visible spectral ranges. The interplay between the intrinsic plasmonic nonlinearity of ITO-NRAs and the phase transition induced permittivity change of VO 2 gives rise to spectral and temporal responses that cannot be achieved with individual material components alone.

  20. Chemical composition of an aqueous oxalato-/citrato-VO(2+) solution as determinant for vanadium oxide phase formation.

    PubMed

    Peys, Nick; Maurelli, Sara; Reekmans, Gunter; Adriaensens, Peter; De Gendt, Stefan; Hardy, An; Van Doorslaer, Sabine; Van Bael, Marlies K

    2015-01-05

    Aqueous solutions of oxalato- and citrato-VO(2+) complexes are prepared, and their ligand exchange reaction is investigated as a function of the amount of citrate present in the aqueous solution via continuous-wave electron paramagnetic resonance (CW EPR) and hyperfine sublevel correlation (HYSCORE) spectroscopy. With a low amount of citrate, monomeric cis-oxalato-VO(2+) complexes occur with a distorted square-pyramidal geometry. As the amount of citrate increases, oxalate is gradually exchanged for citrate. This leads to (i) an intermediate situation of monomeric VO(2+) complexes with a mix of oxalate/citrate ligands and (ii) a final situation of both monomeric and dimeric complexes with exclusively citrato ligands. The monomeric citrato-VO(2+) complexes dominate (abundance > 80%) and are characterized by a 6-fold chelation of the vanadium(IV) ion by 4 RCO2(-) ligands at the equatorial positions and a H2O/R-OH ligand at the axial position. The different redox stabilities of these complexes, relative to that of dissolved O2 in the aqueous solution, is analyzed via (51)V NMR. It is shown that the oxidation rate is the highest for the oxalato-VO(2+) complexes. In addition, the stability of the VO(2+) complexes can be drastically improved by evacuation of the dissolved O2 from the solution and subsequent storage in a N2 ambient atmosphere. The vanadium oxide phase formation process, starting with the chemical solution deposition of the aqueous solutions and continuing with subsequent processing in an ambient 0.1% O2 atmosphere, differs for the two complexes. The oxalato-VO(2+) complexes turn into the oxygen-deficient crystalline VO2 B at 400 °C, which then turns into crystalline V6O13 at 500 °C. In contrast, the citrato-VO(2+) complexes form an amorphous film at 400 °C that crystallizes into VO2 M1 and V6O13 at 500 °C.

  1. Spanish genetic admixture is associated with larger V(O2) max decrement from sea level to 4338 m in Peruvian Quechua.

    PubMed

    Brutsaert, Tom D; Parra, Esteban J; Shriver, Mark D; Gamboa, Alfredo; Palacios, Jose-Antonio; Rivera, Maria; Rodriguez, Ivette; León-Velarde, Fabiola

    2003-08-01

    Quechua in the Andes may be genetically adapted to altitude and able to resist decrements in maximal O2 consumption in hypoxia (DeltaVo2 max). This hypothesis was tested via repeated measures of Vo2 max (sea level vs. 4338 m) in 30 men of mixed Spanish and Quechua origins. Individual genetic admixture level (%Spanish ancestry) was estimated by using ancestry-informative DNA markers. Genetic admixture explained a significant proportion of the variability in DeltaVo2 max after control for covariate effects, including sea level Vo2 max and the decrement in arterial O2 saturation measured at Vo2 max (DeltaSpO2 max) (R2 for admixture and covariate effects approximately 0.80). The genetic effect reflected a main effect of admixture on DeltaVo2 max (P = 0.041) and an interaction between admixture and DeltaSpO2 max (P = 0.018). Admixture predicted DeltaVo2 max only in subjects with a large DeltaSpO2 max (P = 0.031). In such subjects, DeltaVo2 max was 12-18% larger in a subgroup of subjects with high vs. low Spanish ancestry, with least squares mean values (+/-SE) of 739 +/- 71 vs. 606 +/- 68 ml/min, respectively. A trend for interaction (P = 0.095) was also noted between admixture and the decrease in ventilatory threshold at 4338 m. As previously, admixture predicted DeltaVo2 max only in subjects with a large decrease in ventilatory threshold. These findings suggest that the genetic effect on DeltaVo2 max depends on a subject's aerobic fitness. Genetic effects may be more important (or easier to detect) in athletic subjects who are more likely to show gas-exchange impairment during exercise. The results of this study are consistent with the evolutionary hypothesis and point to a better gas-exchange system in Quechua.

  2. Prediction of Maximal Oxygen Uptake by Six-Minute Walk Test and Body Mass Index in Healthy Boys.

    PubMed

    Jalili, Majid; Nazem, Farzad; Sazvar, Akbar; Ranjbar, Kamal

    2018-05-14

    To develop an equation to predict maximal oxygen uptake (VO2max) based on the 6-minute walk test (6MWT) and body composition in healthy boys. Direct VO2max, 6-minute walk distance, and anthropometric characteristics were measured in 349 healthy boys (12.49 ± 2.72 years). Multiple regression analysis was used to generate VO2max prediction equations. Cross-validation of the VO2max prediction equations was assessed with predicted residual sum of squares statistics. Pearson correlation was used to assess the correlation between measured and predicted VO2max. Objectively measured VO2max had a significant correlation with demographic and 6MWT characteristics (R = 0.11-0.723, P < .01). Multiple regression analysis revealed the following VO2max prediction equation: VO2max (mL/kg/min) = 12.701 + (0.06 × 6-minute walk distance m ) - (0.732 × body mass index kg/m2 ) (R 2 = 0.79, standard error of the estimate [SEE] = 2.91 mL/kg/min, %SEE = 6.9%). There was strong correlation between measured and predicted VO2max (r = 0.875, P < .001). Cross-validation revealed minimal shrinkage (R 2 p = 0.78 and predicted residual sum of squares SEE = 2.99 mL/kg/min). This study provides a relatively accurate and convenient VO2max prediction equation based on the 6MWT and body mass index in healthy boys. This model can be used for evaluation of cardiorespiratory fitness of boys in different settings. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Construction of plasmonic Ag modified phosphorous-doped ultrathin g-C3N4 nanosheets/BiVO4 photocatalyst with enhanced visible-near-infrared response ability for ciprofloxacin degradation.

    PubMed

    Deng, Yaocheng; Tang, Lin; Feng, Chengyang; Zeng, Guangming; Wang, Jiajia; Zhou, Yaoyu; Liu, Yani; Peng, Bo; Feng, Haopeng

    2018-02-15

    To realize the full utilization of solar energy, the design of highly efficient photocatalyst with improved visible-near-infrared photocatalysis performance has attracted great attentions for environment pollutant removal. In this work, we rationally employed the surface plasmon resonance effect of metallic Ag in the phosphorus doped ultrathin g-C 3 N 4 nanosheets (PCNS) and BiVO 4 composites to construct a ternary Ag@PCNS/BiVO 4 photocatalyst. It was applied for the photodegradation of ciprofloxacin (CIP), exhibiting 92.6% removal efficiency under visible light irradiation (λ>420nm) for 10mg/L CIP, and presenting enhanced photocatalytic ability than that of single component or binary nanocomposites under near-infrared light irradiation (λ>760nm). The improved photocatalytic activity of the prepared Ag@PCNS/BiVO 4 nanocomposite can be attributed to the synergistic effect among the PCNS, BiVO 4 and Ag, which not only improves the visible light response ability and hinders the recombination efficiency of the photogenerated electrons and holes, but also retains the strong the redox ability of the photogenerated charges. According to the trapping experiment and ESR measurements results, OH, h + and O 2 - all participated in the photocatalytic degradation process. Considering the SPR effect of metallic Ag and the established local electric field around the interfaces, a dual Z-scheme electrons transfer mechanism was proposed. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Shape-controlled synthesis and influence of W doping and oxygen nonstoichiometry on the phase transition of VO2

    PubMed Central

    Chen, Ru; Miao, Lei; Liu, Chengyan; Zhou, Jianhua; Cheng, Haoliang; Asaka, Toru; Iwamoto, Yuji; Tanemura, Sakae

    2015-01-01

    Monoclinic VO2(M) in nanostructure is a prototype material for interpreting correlation effects in solids with fully reversible phase transition and for the advanced applications to smart devices. Here, we report a facile one-step hydrothermal method for the controlled growth of single crystalline VO2(M/R) nanorods. Through tuning the hydrothermal temperature, duration of the hydrothermal time and W-doped level, single crystalline VO2(M/R) nanorods with controlled aspect ratio can be synthesized in large quantities, and the crucial parameter for the shape-controlled synthesis is the W-doped content. The dopant greatly promotes the preferential growth of (110) to form pure phase VO2(R) nanorods with high aspect ratio for the W-doped level = 2.0 at% sample. The shape-controlled process of VO2(M/R) nanorods upon W-doping are systematically studied. Moreover, the phase transition temperature (Tc) of VO2 depending on oxygen nonstoichiometry is investigated in detail. PMID:26373612

  5. F-region enhancements induced by solar flares

    NASA Technical Reports Server (NTRS)

    Donnelly, R. F.; Davies, K.; Grubb, R. N.; Fritz, R. B.

    1976-01-01

    ATS-6 total electron content (NT) observations during solar flares exhibit four types of response: (1) a sudden increase in NT (SITEC) for about 2 min with several maxima in growth rate, then a maximum or a distinct slowing in growth, followed by a slow smooth increase to a flat peak, and finally a slow decay in NT; (2) a SITEC that occurs during ionospheric storms, where NT decays abruptly after the first maximum; (3) slow enhancements devoid of distinct impulsive structure in growth rate; and (4) no distinct response in NT, even for relatively large soft X-ray flares. Flare-induced increases in NT are dominated by low-loss F2 ionization produced by 90-911-A emission. The impulsive flare component is relatively intense in the 90-911-A range, but is short lived and weak for flares near the edge of the visible solar disk and for certain slow flares. The impulsive flare component produces the rapid rise, the sharp maxima in growth rate, and the first maximum in SITECs. The slow flare components are strong in the 1-90-A range but relatively weak in the 90-911-A range and accumulatively contribute to the second maximum in type 1 and 3 events, except during storms when F2 loss rates are abnormally high in type 2 events.

  6. The alveolar to arterial oxygen partial pressure difference is associated with pulmonary diffusing capacity in heart failure patients.

    PubMed

    Morosin, Marco; Vignati, Carlo; Novi, Angela; Salvioni, Elisabetta; Veglia, Fabrizio; Alimento, Marina; Merli, Guido; Sciomer, Susanna; Sinagra, Gianfranco; Agostoni, Piergiuseppe

    2016-11-01

    In chronic heart failure (HF), the alveolar-capillary membrane undergoes a remodeling process that negatively affects gas exchange. In case of alveolar-capillary gas diffusion impairment, arterial desaturation (SaO 2 ) is rarely observed in HF patients. At play are 3 factors: overall pulmonary diffusing capacity (assessed as lung diffusion for CO, DLCO), global O 2 consumption (VO 2 ) and alveolar (A) to arterial (a) pO 2 gradient (AaDO 2 ). In 100 consecutive stable HF patients, DLCO, resting respiratory gases and arterial blood gases were measured to determine VO 2, paO 2 , pAO 2 and AaDO 2 . DLCO was poorly but significantly related to AaDO 2 . The correlation improved after correcting AaDO 2 for VO 2 (p<0.001, r=0.49). Both VO 2 and AaDO 2 were independently associated with DLCO (p<0.001). Patients with reduced DLCO showed no differences as regards paO 2 and pAO 2 . AaDO 2 /VO 2 showed a higher gradient in patients with lower DLCO. AaDO 2 increase and VO 2 reduction allow preventing low SaO 2 in HF patients with reduced DLCO. Accordingly, we suggest considering AaDO 2 and VO 2 combined and reporting AaDO 2 /VO 2 . Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Relationship between inflammatory markers of cardiovascular disease and VO2peak in asymptomatic females.

    PubMed

    Omran Simin, F; Narges, Z; Sajad, A; Parisa, Y; Omrani Vahid, F

    2013-04-01

    The objective of this study was to investigate the relationship between inflammatory markers of cardiovascular disease (IL-6 and acute-phase reactants) and VO2peak in asymptomatic females. Study subjects were females not affected by coronary heart diseases. Forty healthy female subjects (age, 45±4.2 years; height, 161±3.5 cm; weight, 65±3.1 kg; history of regular physical activity, 5.2±0.45 years) participated in this study Analysis of data was carried out by Pearson's correlation. Statistical analysis of data indicated a negative significant relationship between IL-6 and VO2peak (r=-0.48, r2=0.23, P<0.048), CRP and VO2peak (r=-0.40, r2= 0.16, P<0.002), fibrinogen and VO2peak (r=-0.42, r2=0.17, P<0.001), and WBC and VO2peak (r=-0.22, r2=0.04, P<0.044). In conclusion higher circulating levels of IL-6, CRP and fibrinogen are associated with lower VO2peak in females.

  8. Control of electromagnetically induced transparency via a hybrid semiconductor quantum dot-vanadium dioxide nanoparticle system

    NASA Astrophysics Data System (ADS)

    Zamani, Naser; Hatef, Ali; Nadgaran, Hamid; Keshavarz, Alireza

    2017-07-01

    We numerically investigate the electromagnetically induced transparency (EIT) of a hybrid system consisting of a three-level quantum dot (QD) in the vicinity of vanadium dioxide nanoparticle (VO2NP). VO2NP has semiconductor and metallic phases where the transition between the two phases occurs around a critical temperature. When the QD-VO2NP hybrid system interacts with continuous wave laser fields in an infrared regime, it supports a coherent coupling of exciton-polariton and exciton-plasmon polariton in semiconductor and metal phases of VO2NP, respectively. In our calculations a filling fraction factor controls the VO2NP phase transition. A probe and control laser field configuration is studied for the hybrid system to measure the absorption of QD through the filling fraction factor manipulations. We show that for the VO2NP semiconductor phase and proper geometrical configuration, the absorption spectrum profile of the QD represents an EIT with two peaks and a clear minimum. These two peaks merge to one through the VO2NP phase transition to metal. We also show that the absorption spectrum profile is modified by different orientations of the laser fields with the axis of the QD-VO2NP hybrid system. The innovation in comparison to other research in the field is that robust variation in the absorption profile through EIT is due to the phase transition in VO2NP without any structural change in the QD-VO2NP hybrid system. Our results can be employed to design nanothermal sensors, optical nanoswitches, and energy transfer devices.

  9. Physiological response to the 6-minute walk test in chronic heart failure patients versus healthy control subjects.

    PubMed

    Deboeck, Gaël; Van Muylem, Alain; Vachiéry, Jean Luc; Naeije, Robert

    2014-08-01

    The distance walked in 6 minutes (6MWD) has been reported to be linearly related to peak oxygen uptake (VO2) in cardiac diseases and in lung diseases. In these patients, the VO2 during a 6-min walk test (walkVO2) has been found to be nearly equivalent to peakVO2, but with a lower respiratory exchange ratio (RER). Whether these observations translate to the less functionally impaired patients or healthy control subjects is not exactly known. Thirty-two healthy control subjects and 15 chronic heart failure (CHF) patients performed a 6-min walk test and a maximal cardiopulmonary exercise test (CPET) both with measurements of gas exchange. The 6MWD and peakVO2 were linearly correlated, but with an increased slope appearing above 532 m. In CHF patients, walkVO2 was similar to peakVO2, but with lower heart rate and ventilation than measured at peak exercise. In healthy control subjects, VO2, ventilation and heart rate were lower during the 6-min walk than at maximal exercise but higher than at the anaerobic threshold. The RER during the 6-min walk remained <1 in both groups. Above 500 m, 6MWD becomes less sensitive to any increase in peakVO2. Furthermore, CHF patients and healthy control subjects exercise respectively at maximal and high VO2, but below the anaerobic threshold (as assessed by a CPET) during the 6-min walk test. © The European Society of Cardiology 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  10. Structural and magnetic characterization of the one-dimensional S = 5/2 antiferromagnetic chain system SrMn(VO 4)(OH)

    DOE PAGES

    Sanjeewa, Liurukara D.; Garlea, Vasile O.; McGuire, Michael A.; ...

    2016-06-06

    The descloizite-type compound, SrMn(VO 4)(OH), was synthesized as large single crystals (1-2mm) using a high-temperature high-pressure hydrothermal technique. X-ray single crystal structure analysis reveals that the material crystallizes in the acentric orthorhombic space group of P2 12 12 1 (no. 19), Z = 4. The structure exhibits a one-dimensional feature, with [MnO 4] chains propagating along the a-axis which are interconnected by VO 4 tetrahedra. Raman and infrared spectra were obtained to identify the fundamental vanadate and hydroxide vibrational modes. Magnetization data reveal a broad maximum at approximately 80 K, arising from one-dimensional magnetic correlations with intrachain exchange constant ofmore » J/k B = 9.97(3) K between nearest Mn neighbors and a canted antiferromagnetic behavior below T N = 30 K. Single crystal neutron diffraction at 4 K yielded a magnetic structure solution in the lower symmetry of the magnetic space group P2 1 with two unique chains displaying antiferromagnetically ordered Mn moments oriented nearly perpendicular to the chain axis. Lastly, the presence of the Dzyaloshinskii Moriya antisymmetric exchange interaction leads to a slight canting of the spins and gives rise to a weak ferromagnetic component along the chain direction.« less

  11. Lung function parameters improve prediction of VO2peak in an elderly population: The Generation 100 study.

    PubMed

    Hassel, Erlend; Stensvold, Dorthe; Halvorsen, Thomas; Wisløff, Ulrik; Langhammer, Arnulf; Steinshamn, Sigurd

    2017-01-01

    Peak oxygen uptake (VO2peak) is an indicator of cardiovascular health and a useful tool for risk stratification. Direct measurement of VO2peak is resource-demanding and may be contraindicated. There exist several non-exercise models to estimate VO2peak that utilize easily obtainable health parameters, but none of them includes lung function measures or hemoglobin concentrations. We aimed to test whether addition of these parameters could improve prediction of VO2peak compared to an established model that includes age, waist circumference, self-reported physical activity and resting heart rate. We included 1431 subjects aged 69-77 years that completed a laboratory test of VO2peak, spirometry, and a gas diffusion test. Prediction models for VO2peak were developed with multiple linear regression, and goodness of fit was evaluated. Forced expiratory volume in one second (FEV1), diffusing capacity of the lung for carbon monoxide and blood hemoglobin concentration significantly improved the ability of the established model to predict VO2peak. The explained variance of the model increased from 31% to 48% for men and from 32% to 38% for women (p<0.001). FEV1, diffusing capacity of the lungs for carbon monoxide and hemoglobin concentration substantially improved the accuracy of VO2peak prediction when added to an established model in an elderly population.

  12. Optical switching and photoluminescence in erbium-implanted vanadium dioxide thin films

    NASA Astrophysics Data System (ADS)

    Lim, Herianto; Stavrias, Nikolas; Johnson, Brett C.; Marvel, Robert E.; Haglund, Richard F.; McCallum, Jeffrey C.

    2014-03-01

    Vanadium dioxide (VO2) is under intensive consideration for optical switching due to its reversible phase transition, which features a drastic and rapid shift in infrared reflectivity. Classified as an insulator-to-metal transition, the phase transition in VO2 can be induced thermally, electrically, and optically. When induced optically, the transition can occur on sub-picosecond time scales. It is interesting to dope VO2 with erbium ions (Er3+) and observe their combined properties. The first excited-state luminescence of Er3+ lies within the wavelength window of minimal transmission-loss in silicon and has been widely utilized for signal amplification and generation in silicon photonics. The incorporation of Er3+ into VO2 could therefore result in a novel photonic material capable of simultaneous optical switching and amplification. In this work, we investigate the optical switching and photoluminescence in Er-implanted VO2 thin films. Thermally driven optical switching is demonstrated in the Er-implanted VO2 by infrared reflectometry. Photoluminescence is observed in the thin films annealed at ˜800 °C or above. In addition, Raman spectroscopy and a statistical analysis of switching hysteresis are carried out to assess the effects of the ion implantation on the VO2 thin films. We conclude that Er-implanted VO2 can function as an optical switch and amplifier, but with reduced switching quality compared to pure VO2.

  13. Hydrothermal Synthesis of VO2 Polymorphs: Advantages, Challenges and Prospects for the Application of Energy Efficient Smart Windows.

    PubMed

    Li, Ming; Magdassi, Shlomo; Gao, Yanfeng; Long, Yi

    2017-09-01

    Vanadium dioxide (VO 2 ) is a widely studied inorganic phase change material, which has a reversible phase transition from semiconducting monoclinic to metallic rutile phase at a critical temperature of τ c ≈ 68 °C. The abrupt decrease of infrared transmittance in the metallic phase makes VO 2 a potential candidate for thermochromic energy efficient windows to cut down building energy consumption. However, there are three long-standing issues that hindered its application in energy efficient windows: high τ c , low luminous transmittance (T lum ), and undesirable solar modulation ability (ΔT sol ). Many approaches, including nano-thermochromism, porous films, biomimetic surface reconstruction, gridded structures, antireflective overcoatings, etc, have been proposed to tackle these issues. The first approach-nano-thermochromism-which is to integrate VO 2 nanoparticles in a transparent matrix, outperforms the rest; while the thermochromic performance is determined by particle size, stoichiometry, and crystallinity. A hydrothermal method is the most common method to fabricate high-quality VO 2 nanoparticles, and has its own advantages of large-scale synthesis and precise phase control of VO 2 . This Review focuses on hydrothermal synthesis, physical properties of VO 2 polymorphs, and their transformation to thermochromic VO 2 (M), and discusses the advantages, challenges, and prospects of VO 2 (M) in energy-efficient smart windows application. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Facile Approach to Preparing a Vanadium Oxide Hydrate Layer as a Hole-Transport Layer for High-Performance Polymer Solar Cells.

    PubMed

    Cong, Hailin; Han, Dongwei; Sun, Bingbing; Zhou, Dongying; Wang, Chen; Liu, Ping; Feng, Lai

    2017-05-31

    We demonstrate a facile and green approach to preparing a vanadium oxide hydrate (VO x ·nH 2 O) layer to serve as the hole-transport layer (HTL) in high-performance polymer solar cells (PSCs). The VO x ·nH 2 O layer was in situ prepared by a combined H 2 O 2 and ultraviolet-ozone (UVO) processing on a VO x layer. The as-prepared VO x ·nH 2 O layer featured a work function of 5.0 ± 0.1 eV, high transmittance, and better interface properties compared to those of the generally prepared VO x (UVO or thermal annealing) layers. PSCs based on poly[(ethylhexyl-thiophenyl)-benzodithiophene-(ethylhexyl)-thienothiophene]/[6,6]-phenyl-C 71 -butyric acid methyl ester using the VO x ·nH 2 O layer as the HTL yielded high power conversion efficiencies (PCEs) up to 8.11%, outperforming the devices with VO x layers (PCE of 6.79% for the UVO-processed VO x layer and 6.10% for the thermally annealed VO x layer) and conventional polyethylenedioxythiophene-polystyrenesulfonate (PEDOT:PSS) layers (PCE of 7.67%). The improved PCE was attributed to the enhanced J SC and/or fill factor, which mainly correlate to the improved interfacial contact between the photoactive layer and the indium tin oxide/HTL or cathode when using the VO x ·nH 2 O layer as the HTL. A similar improvement in the PCE was also observed for the PSCs based on poly(3-hexylthiophene)/[6,6]-phenyl-C 61 -butyric acid methyl ester. In addition, PSCs with a VO x ·nH 2 O layer as the HTL showed a higher stability than that of those with a PEDOT:PSS layer. Hence, it would be possible to use this simply and in situ prepared VO x ·nH 2 O layer as an inexpensive HTL for high-performance PSCs.

  15. Min-By-Min Respiratory Exchange and Oxygen Uptake Kinetics During Steady-State Exercise in Subjects of High and Low Max VO2

    ERIC Educational Resources Information Center

    Weltman, Arthur; Katch, Victor

    1976-01-01

    No statistically meaningful differences in steady-state vo2 uptake for high and low max vo2 groups was indicated in this study, but a clear tendency was observed for the high max vo2 group to reach the steady-state at a faster rate. (MB)

  16. The fabrication and visible-near-infrared optical modulation of vanadium dioxide/silicon dioxide composite photonic crystal structure

    NASA Astrophysics Data System (ADS)

    Liang, Jiran; Li, Peng; Song, Xiaolong; Zhou, Liwei

    2017-12-01

    We demonstrated a visible and near-infrared light tunable photonic nanostructure, which is composed of vanadium dioxide (VO2) thin film and silicon dioxide (SiO2) ordered nanosphere arrays. The vanadium films were sputtered on two-dimensional (2D) SiO2 sphere arrays. VO2 thin films were prepared by rapid thermal annealing (RTA) method with different oxygen flow rates. The close-packed VO2 shell formed a continuous surface, the composition of VO2 films in the structure changed when the oxygen flow rates increased. The 2D VO2/SiO2 composite photonic crystal structure exhibited transmittance trough tunability and near-infrared (NIR) transmittance modulation. When the oxygen flow rate increased from 3 slpm to 4 slpm, the largest transmittance trough can be regulated from 904 to 929 nm at low temperature, the transmittance troughs also appear blue shift when the VO2 phase changes from insulator to metal. The composite nanostructure based on VO2 films showed visible transmittance tunability, which would provide insights into the glass color changing in smart windows.

  17. Atomic layer deposition of VO2 films with Tetrakis-dimethyl-amino vanadium (IV) as vanadium precursor

    NASA Astrophysics Data System (ADS)

    Lv, Xinrui; Cao, Yunzhen; Yan, Lu; Li, Ying; Song, Lixin

    2017-02-01

    VO2 thin films have been grown on Si(100) (VO2/Si) and fused silica substrates (VO2/SiO2) by atomic layer deposition (ALD) using tetrakis-dimethyl-amino vanadium (IV) (TDMAV) as a novel vanadium precursor and water as reactant gas. The quartz crystal microbalance (QCM) measurement was performed to study the ALD process of VO2 thin film deposition, and a constant growth rate of about 0.95 Å/cycle was obtained at the temperature range of 150-200 °C. XRD measurement was performed to study the influence of deposition temperature and post-annealing condition on the crystallization of VO2 films, which indicated that the films deposited between 150 and 200 °C showed well crystallinity after annealing at 475 °C for 100 min in Ar atmosphere. XPS measurement verified that the vanadium oxidation state was 4+ for both as-deposited film and post-annealed VO2/Si film. AFM was applied to study the surface morphology of VO2/Si films, which showed a dense polycrystalline film with roughness of about 1 nm. The resistance of VO2/Si films deposited between 150 °C and 200 °C as a function of temperature showed similar semiconductor-to-metal transition (SMT) characters with the transition temperature for heating branch (Tc,h) of about 72 °C, a hysteresis width of about 10 °C and the resistance change of two orders of magnitude. The increase of Tc,h compared with the bulk VO2 (68 °C) may be attributed to the tensile stress along the c-axis in the film. Transmittance measurement of VO2/SiO2 films showed typical thermochromic property with a NIR switching efficiency of above 50% at 2 μm across the transition.

  18. Determinants of Exercise Intolerance in Elderly Heart Failure Patients with Preserved Ejection Fraction

    PubMed Central

    Haykowsky, Mark J.; Brubaker, Peter H.; John, Jerry M.; Stewart, Kathryn P.; Morgan, Timothy M.; Kitzman, Dalane W.

    2011-01-01

    Objectives To determine the mechanisms responsible for reduced aerobic capacity (peak VO2) in heart failure patients with preserved ejection fraction (HFPEF). Background HFPEF is the predominant form of HF in older persons. Exercise intolerance is the primary symptom among patients with HFPEF and a major determinant of reduced quality of life. In contrast to patients with HF and reduced EF, the mechanism of exercise intolerance in HFPEF is less well understood. Methods Left ventricular volumes (2D echocardiography), cardiac output (CO), VO2 and calculated arterial-venous oxygen content difference (A-VO2 Diff) were measured at rest and during incremental, exhaustive upright cycle exercise in 48 HFPEF patients (age 69±6 years) and 25 healthy age-matched controls (HC). Results In HFPEF compared to HC, VO2 was reduced at peak exercise (mean±SE: 14.3±0.5 vs. 20.4±0.6 mL·kg min−1; p<0.0001) and was associated with a reduced peak CO (6.3±0.2 vs. 7.6±0.2 L·min−1, p<0.0001) and A-VO2 Diff (17±0.4 vs. 19±0.4 ml·dl−1, p<0.0007). The strongest independent predictor of peak VO2 was the change in A-VO2 Diff from rest to peak exercise (A-VO2 Diff reserve) for both HFPEF (partial correlant 0.58, standardized β coefficient 0.66; p=0.0002) and HC (partial correlant 0.61, standardized β coefficient 0.41; p=0.005) Conclusions Both reduced CO and A-VO2 Diff contribute significantly to the severe exercise intolerance in elderly HFPEF patients. The finding that A-VO2 Diff reserve is an independent predictor of peak exercise VO2 suggests that peripheral, ‘non-cardiac’ factors are important contributors to exercise intolerance in these patients. PMID:21737017

  19. Changes in ventilatory threshold with exercise training in a sedentary population: the HERITAGE Family Study.

    PubMed

    Gaskill, S E; Walker, A J; Serfass, R A; Bouchard, C; Gagnon, J; Rao, D C; Skinner, J S; Wilmore, J H; Leon, A S

    2001-11-01

    The purpose of this study was to evaluate the effect of exercise training intensity relative to the ventilatory threshold (VT) on changes in work (watts) and VO2 at the ventilatory threshold and at maximal exercise in previously sedentary participants in the HERITAGE Family Study. We hypothesized that those who exercised below their VT would improve less in VO2 at the ventilatory threshold (VO2vt) and VO2max than those who trained at an intensity greater than their VT. Supervised cycle ergometer training was performed at the 4 participating clinical centers, 3 times a week for 20 weeks. Exercise training progressed from the HR corresponding to 55% VO2max for 30 minutes to the HR associated with 75% VO2max for 50 minutes for the final 6 weeks. VT was determined at baseline and after exercise training using standardized methods. 432 sedentary white and black men (n = 224) and women (n = 208), aged 17 to 65 years, were retrospectively divided into groups based on whether exercise training was initiated below, at, or above VT. 1) Training intensity (relative to VT) accounting for about 26% of the improvement in VO2vt (R2 = 0.26, p < 0.0001). 2) The absolute intensity of training in watts (W) accounted for approximately 56% of the training effect at VT (R2 = 0.56, p < 0.0001) with post-training watts at VT (VT(watts)) being not significantly different than W during training (p > 0.70). 3) Training intensity (relative to VT) had no effect on DeltaVO2max. These data clearly show that as a result of aerobic training both the VO2 and W associated with VT respond and become similar to the absolute intensity of sustained (3 x /week for 50 min) aerobic exercise training. Higher intensities of exercise, relative to VT, result in larger gains in VO2vt but not in VO2max.

  20. Defect engineering of the oxygen-vacancy clusters formation in electron irradiated silicon by isovalent doping: An infrared perspective

    NASA Astrophysics Data System (ADS)

    Londos, C. A.; Sgourou, E. N.; Chroneos, A.

    2012-12-01

    Infrared spectroscopy was used to study the production and evolution of oxygen-vacancy (VOn for n = 1, 2, 3 and VmO for m = 1, 2, 3) clusters, in electron-irradiated Czochralski silicon (Cz-Si) samples, doped with isovalent dopants. It was determined that the production of the VO pair is enhanced in Ge-doped Si but is suppressed in Sn and Pb-doped Si. The phenomenon is discussed in terms of the competition between isovalent dopants and oxygen atoms in capturing vacancies in the course of irradiation. In the case of Ge, only transient GeV pairs form, leading finally to an increase of the VO production. Conversely, for Sn and Pb the corresponding pairs with vacancies are stable, having an opposite impact on the formation of VO pairs. Regarding V2O and V3O clusters, our measurements indicate that Ge doping enhances their formation, although Sn and Pb dopants suppress it. Similar arguments as those for the VO pair could be put forward, based on the effect of isovalent impurities on the availability of vacancies. Additionally, it was found that the conversion ratio of VO to VO2 decreases as the covalent radius of the isovalent dopant increases. These results are discussed in terms of the local strains introduced by the isovalent dopants in the Si lattice. These local strains affect the balance of the intrinsic defects created as a result of irradiation, as well as the balance between the two main reactions (VO + Oi → VO2 and VO + SiI → Oi) participating in the VO annealing, leading finally to a decrease of the VO2 production. The larger the covalent radius of the isovalent dopant (rGe < rSn < rPb), the larger the introduced strains in the lattice and then the less the VO2 formation in accordance with our experimental results. Interestingly, an opposite trend was observed for the conversion ratio of VO2 to VO3. The phenomenon is attributed to the enhanced diffusivity of oxygen impurity as a result of the presence of isovalent dopants, leading to an enhanced formation of the VO3 cluster. The results indicate that isovalent doping of Si is an effective way to control the formation of the deleterious oxygen-vacancy clustering that can affect Si-based devices.

  1. Contribution of central and peripheral factors at peak exercise in heart failure patients with progressive severity of exercise limitation.

    PubMed

    Del Torto, Alberico; Corrieri, Nicoletta; Vignati, Carlo; Gentile, Piero; Cattadori, Gaia; Paolillo, Stefania; Agostoni, Piergiuseppe

    2017-12-01

    A reduced cardiac output (CO) response during exercise is a major limiting factor in heart failure (HF). Oxygen consumption (VO 2 ) is directly proportional to CO. Peripheral mechanisms via arteriovenous oxygen difference (Δ(a-v)O 2 ) play a pivotal role in chronic HF. We hypothesized a weak correlation between peak VO 2 and peak CO with a greater Δ(a-v)O 2 variability in most severe HF. We analyzed 278 HF patients (NYHA II-III) who performed maximal cardiopulmonary exercise test with non-invasive CO measurement by inert gas rebreathing. Median peakVO 2 , CO and Δ(a-v)O 2 were 0.96 (0.78-1.28) L/min, 6.3 (5.1-8.0) L/min and 16.0 (14.2-18.0) mL/100mL respectively, with a linear relationship between VO 2 and CO: CO=5.3×VO 2 +1.13 (r 2 =0.705, p<0.001). Patients were grouped according to exercise limitation. Group 1 (101 patients) peakVO 2 <50% pred: peakVO 2 0.80 (0.67-0.94) L/min, peakCO 5.6 (4.7-6.5) L/min, peakΔ(a-v)O 2 14.8 (12.9-17.1) mL/100mL. Group 2 (89 patients) peakVO 2 ≥50-<65% pred: peakVO 2 1.02 (0.84-1.29) L/min, peakCO 6.4 (5.1-8.0) L/min, peakΔ(a-v)O 2 16.7 (15.0-18.5) mL/100mL. Group 3 (88 patients) peakVO 2 ≥65% pred: peakVO 2 1.28 (0.93-1.66) L/min, peakCO 8.0 (6.2-9.7) L/min, peakΔ(a-v)O 2 16.8 (14.6-18.3) mL/100mL. A peakVO 2 and peakCO linear relationship was observed in Group 1 (r 2 =0.381, p<0.001), Group 2 (r 2 =0.756, p<0.001) and Group 3 (r 2 =0.744, p<0.001). With worsening HF we observed a progressive reduction of peak CO and peak VO 2 . However in most compromised patients also peripheral mechanisms play a role as indicated by reduced Δ(a-v)O 2 . Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Heart rate during basketball game play and volleyball drills accurately predicts oxygen uptake and energy expenditure.

    PubMed

    Scribbans, T D; Berg, K; Narazaki, K; Janssen, I; Gurd, B J

    2015-09-01

    There is currently little information regarding the ability of metabolic prediction equations to accurately predict oxygen uptake and exercise intensity from heart rate (HR) during intermittent sport. The purpose of the present study was to develop and, cross-validate equations appropriate for accurately predicting oxygen cost (VO2) and energy expenditure from HR during intermittent sport participation. Eleven healthy adult males (19.9±1.1yrs) were recruited to establish the relationship between %VO2peak and %HRmax during low-intensity steady state endurance (END), moderate-intensity interval (MOD) and high intensity-interval exercise (HI), as performed on a cycle ergometer. Three equations (END, MOD, and HI) for predicting %VO2peak based on %HRmax were developed. HR and VO2 were directly measured during basketball games (6 male, 20.8±1.0 yrs; 6 female, 20.0±1.3yrs) and volleyball drills (12 female; 20.8±1.0yrs). Comparisons were made between measured and predicted VO2 and energy expenditure using the 3 equations developed and 2 previously published equations. The END and MOD equations accurately predicted VO2 and energy expenditure, while the HI equation underestimated, and the previously published equations systematically overestimated VO2 and energy expenditure. Intermittent sport VO2 and energy expenditure can be accurately predicted from heart rate data using either the END (%VO2peak=%HRmax x 1.008-17.17) or MOD (%VO2peak=%HRmax x 1.2-32) equations. These 2 simple equations provide an accessible and cost-effective method for accurate estimation of exercise intensity and energy expenditure during intermittent sport.

  3. The preparation of a plasmonically resonant VO2 thermochromic pigment.

    PubMed

    Bai, Huaping; Cortie, Michael B; Maaroof, Abbas I; Dowd, Annette; Kealley, Catherine; Smith, Geoffrey B

    2009-02-25

    Vanadium dioxide (VO(2)) undergoes a reversible metal-insulator transition, normally at approximately 68 degrees C. While the properties of continuous semi-transparent coatings of VO(2) are well known, there is far less information available concerning the potential use of discrete VO(2) nanoparticles as a thermochromic pigment in opaque coatings. Individual VO(2) nanoparticles undergo a localized plasmon resonance with near-infrared light at about 1100 nm and this resonance can be switched on and off by simply varying the temperature of the system. Therefore, incorporation of VO(2) nanoparticles into a coating system imbues the coating with the ability to self-adaptively modulate its own absorptive efficiency in the near-infrared. Here we examine the magnitude and control of this phenomenon. Prototype coatings are described, made using VO(2) powder produced by an improved process. The materials are characterized using calorimetry, x-ray diffraction, high-resolution scanning electron microscopy, transmission electron microscopy, and by measurement of optical properties.

  4. Tailoring of the thermomechanical performance of VO2 nanowire bimorph actuators by ion implantation

    NASA Astrophysics Data System (ADS)

    Karl, H.; Peyinghaus, S. C.

    2015-12-01

    Vanadium dioxide VO2 nanowire bimorph actuators work on the basis of the large abrupt length change at the metal-insulator phase transition (MIT). A key parameter for the bimorph performance and efficiency is the bending curvature and the width of the temperature hysteresis of the MIT which is inherently large for single domain VO2 metal side coated nanowires. In this work we present single-clamped Ir side coated VO2 bimorphs which show unprecedented high bending curvatures of up to 105 m-1 and new type of side ion-implanted VO2 nanowire bimorph actuators with a nearly completely suppressed temperature hysteresis. It is assumed that ion-beam induced radiation defects in the VO2 crystal structure act as nucleation sites for the MIT. Moreover it will be shown that mechanical strain intentionally built-in during VO2 nanowire bimorph fabrication allows to direct phase transformation via a strain stabilized metastable phase and thus allows to control bending response on temperature change.

  5. VO2/TiO2 Nanosponges as Binder-Free Electrodes for High-Performance Supercapacitors

    NASA Astrophysics Data System (ADS)

    Hu, Chenchen; Xu, Henghui; Liu, Xiaoxiao; Zou, Feng; Qie, Long; Huang, Yunhui; Hu, Xianluo

    2015-11-01

    VO2/TiO2 nanosponges with easily tailored nanoarchitectures and composition were synthesized by electrostatic spray deposition as binder-free electrodes for supercapacitors. Benefiting from the unique interconnected pore network of the VO2/TiO2 electrodes and the synergistic effect of high-capacity VO2 and stable TiO2, the as-formed binder-free VO2/TiO2 electrode exhibits a high capacity of 86.2 mF cm-2 (~548 F g-1) and satisfactory cyclability with 84.3% retention after 1000 cycles. This work offers an effective and facile strategy for fabricating additive-free composites as high-performance electrodes for supercapacitors.

  6. VO2/TiO2 Nanosponges as Binder-Free Electrodes for High-Performance Supercapacitors

    PubMed Central

    Hu, Chenchen; Xu, Henghui; Liu, Xiaoxiao; Zou, Feng; Qie, Long; Huang, Yunhui; Hu, Xianluo

    2015-01-01

    VO2/TiO2 nanosponges with easily tailored nanoarchitectures and composition were synthesized by electrostatic spray deposition as binder-free electrodes for supercapacitors. Benefiting from the unique interconnected pore network of the VO2/TiO2 electrodes and the synergistic effect of high-capacity VO2 and stable TiO2, the as-formed binder-free VO2/TiO2 electrode exhibits a high capacity of 86.2 mF cm−2 (~548 F g−1) and satisfactory cyclability with 84.3% retention after 1000 cycles. This work offers an effective and facile strategy for fabricating additive-free composites as high-performance electrodes for supercapacitors. PMID:26531072

  7. VO2/TiO2 Nanosponges as Binder-Free Electrodes for High-Performance Supercapacitors.

    PubMed

    Hu, Chenchen; Xu, Henghui; Liu, Xiaoxiao; Zou, Feng; Qie, Long; Huang, Yunhui; Hu, Xianluo

    2015-11-04

    VO2/TiO2 nanosponges with easily tailored nanoarchitectures and composition were synthesized by electrostatic spray deposition as binder-free electrodes for supercapacitors. Benefiting from the unique interconnected pore network of the VO2/TiO2 electrodes and the synergistic effect of high-capacity VO2 and stable TiO2, the as-formed binder-free VO2/TiO2 electrode exhibits a high capacity of 86.2 mF cm(-2) (~548 F g(-1)) and satisfactory cyclability with 84.3% retention after 1000 cycles. This work offers an effective and facile strategy for fabricating additive-free composites as high-performance electrodes for supercapacitors.

  8. Influence of VO2 Nanoparticle Morphology on the Colorimetric Assay of H2O2 and Glucose

    PubMed Central

    Tian, Rui; Sun, Jiaheng; Qi, Yanfei; Zhang, Boyu; Guo, Shuanli; Zhao, Mingming

    2017-01-01

    Nanozyme-based colorimetric sensors have received considerable attention due to their unique properties. The size, shape, and surface chemistry of these nanozymes could dramatically influence their sensing behaviors. Herein, a comparative study of VO2 nanoparticles with different morphologies (nanofibers, nanosheets, and nanorods) was conducted and applied to the sensitive colorimetric detection of H2O2 and glucose. The peroxidase-like activities and mechanisms of VO2 nanoparticles were analyzed. Among the VO2 nanoparticles, VO2 nanofibers exhibited the best peroxidase-like activity. Finally, a comparative quantitative detections of H2O2 and glucose were done on fiber, sheet, and rod nanoparticles. Under the optimal reaction conditions, the lower limit of detection (LOD) of the VO2 nanofibers, nanosheets, and nanorods for H2O2 are found to be 0.018, 0.266, and 0.41 mM, respectively. The VO2 nanofibers, nanosheets, and nanorods show the linear response for H2O2 from 0.025–10, 0.488–62.5, and 0.488–15.625 mM, respectively. The lower limit of detection (LOD) of the VO2 nanofibers, nanosheets, and nanorods for glucose are found to be 0.009, 0.348, and 0.437 mM, respectively. The VO2 nanofibers, nanosheets, and nanorods show the linear response for glucose from 0.01–10, 0.625–15, and 0.625–10 mM, respectively. The proposed work will contribute to the nanozyme-based colorimetric assay. PMID:29068412

  9. The effect of intermittent standing or walking during head down tilt bedrest on peak O2 consumption

    NASA Technical Reports Server (NTRS)

    Ertl, A. C.; Dearborn, A. S.; Vernikos, J.

    1992-01-01

    The cardiovascular aspect of bedrest deconditioning is manifested by decreases in peak O2 uptake (VO(sub 2 peak)) during minimal exercise. The effect of intermittent standing (+G(z)) or walking (+G(z)W) during 4 days of 7 degree Head Down Tilt bedrest (HDT) on VO(sub 2 peak) was evaluated. Methods: Five protocols were performed by eight male subjects; control (C) consisting of complete bedrest, and 15 minute periods to total 2 or 4 hours daily of standing (+G(z)(exp 2) and +G(z)(exp 4) respectively) or walking at 3.0 MPH (+G(z)W2 and +G(z)W4 respectively). Subjects performed VO(sub 2 peak) tests prior to and on the final day of HDT. VO(sub 2 peak) was determined using open circuit indirect calorimetry during supine leg cycling ergometry. After a 5 minute warmup, three 2 minute incremental loads of 33 W previously determined to elicit VO(sub 2 peak) were given and the subject cycled to volitional fatigue. Results: The C protocol VO(sub 2 peak) decreased by 16 percent (2.71 plus or minus 0.16 to 2.27 plus or minus 0.14 L/min) and 11 percent in +G(z)(exp 4) (2.72 plus or minus 0.15 to 2.43 plus or minus 0.14 L/min). With +G(z)W2 VO(sub 2 peak) decreased by 9 percent (2.71 plus or minus 0.17 to 2.46 plus or minus 0.14 L/min) and with +G(z)W4, VO(sub 2 peak) decreased by 10 percent (2.71 plus or minus 0.14 to 2.43 plus or minus 0.14 L/min). VO(sub 2 peak) in all protocols decreased with HDT (P less than 0.05). The decrease in C VO(sub 2 peak) was significantly greater (P less than 0.05) than the decreases in either +G(z) or +G(z)W protocols. Conclusion: The deconditioning that occurs after only 4 days of HDT was demonstrated by decreases in VO(sub 2 peak). Intermittent +G(z) or +G(z)W attenuated, but did not prevent, the decrease in VO(sub 2 peak) with HDT.

  10. Influence of catalyst synthesis method on selective catalytic reduction (SCR) of NO by NH 3 with V 2O 5-WO 3/TiO 2 catalysts

    DOE PAGES

    He, Yuanyuan; Ford, Michael E.; Zhu, Minghui; ...

    2016-04-14

    We compared the molecular structures, surface acidity and catalytic activity for NO/NH 3/O 2 SCR of V 2O 5-WO 3/TiO 2 catalysts for two different synthesis methods: co-precipitation of aqueous vanadium and tungsten oxide precursors with TiO(OH) 2 and by incipient wetness impregnation of the aqueous precursors on a reference crystalline TiO 2 support (P25; primarily anatase phase). Bulk analysis by XRD showed that co-precipitation results in small and/or poorly ordered TiO 2(anatase) particles and that VO x and WO x do not form solid solutions with the bulk titania lattice. Surface analysis of the co-precipitated catalyst by High Sensitivity-Lowmore » Energy Ion Scattering (HS-LEIS) confirms that the VO x and WO x are surface segregated for the co-precipitated catalysts. In situ Raman and IR spectroscopy revealed that the vanadium and tungsten oxide components are present as surface mono-oxo O = VO 3 and O = WO 4 sites on the TiO 2 supports. Co-precipitation was shown for the first time to also form new mono-oxo surface VO 4 and WO 4 sites that appear to be anchored at surface defects of the TiO 2 support. IR analysis of chemisorbed ammonia showed the presence of both surface NH 3 * on Lewis acid sites and surface NH 4 +* on Brønsted acid sites. TPSR spectroscopy demonstrated that the specific SCR kinetics was controlled by the redox surface VO 4 species and that the surface kinetics was independent of TiO 2 synthesis method or presence of surface WO 5 sites. SCR reaction studies revealed that the surface WO5 sites possess minimal activity below ~325 °C and their primary function is to increase the adsorption capacity of ammonia. A relationship between the SCR activity and surface acidity was not found. The SCR reaction is controlled by the surface VO 4 sites that initiate the reaction at ~200 °C. The co-precipitated catalysts were always more active than the corresponding impregnated catalysts. Finally, we ascribe the higher activity of the co-precipitated catalysts to the presence of the new surface WO x sites associated surface defects on the TiO 2 support that increase the ammonia adsorption capacity.« less

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Yong; Pan, Xuan; Bernussi, Ayrton A.

    We demonstrate that catalyst-assisted hydrogen spillover doping of VO{sub 2} thin films significantly alters the metal-insulator transition characteristics and stabilizes the metallic rutile phase at room temperature. With hydrogen inserted into the VO{sub 2} lattice, high resolution X-ray diffraction reveals expansion of the V-V chain separation when compared to the VO{sub 2}(R) phase. The donated free electrons, possibly from O-H bond formation, stabilize the VO{sub 2}(R) to low temperatures. By controlling the amount of dopants to obtain mixed insulating and metallic phases, VO{sub 2} resistivity can be continuously tuned until a critical condition is achieved that suppresses Fabry-Perot resonances. Ourmore » results demonstrate that hydrogen spillover is an effective technique to tune the electrical and optical properties of VO{sub 2} thin films.« less

  12. Voltage switching of a VO{sub 2} memory metasurface using ionic gel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldflam, M. D.; Liu, M. K.; Chapler, B. C.

    2014-07-28

    We demonstrate an electrolyte-based voltage tunable vanadium dioxide (VO{sub 2}) memory metasurface. Large spatial scale, low voltage, non-volatile switching of terahertz (THz) metasurface resonances is achieved through voltage application using an ionic gel to drive the insulator-to-metal transition in an underlying VO{sub 2} layer. Positive and negative voltage application can selectively tune the metasurface resonance into the “off” or “on” state by pushing the VO{sub 2} into a more conductive or insulating regime respectively. Compared to graphene based control devices, the relatively long saturation time of resonance modification in VO{sub 2} based devices suggests that this voltage-induced switching originates primarilymore » from electrochemical effects related to oxygen migration across the electrolyte–VO{sub 2} interface.« less

  13. A comparative analysis of physiological responses at submaximal workloads during different laboratory simulations of field cycling.

    PubMed

    Kenny, G P; Reardon, F D; Marion, A; Thoden, J S

    1995-01-01

    The purpose of this study was to evaluate the relationships between heart rate (fc), oxygen consumption (VO2), peak force and average force developed at the crank in response to submaximal exercise employing a racing bicycle which was attached to an ergometer (RE), ridden on a treadmill (TC) and ridden on a 400-m track (FC). Eight male trained competitive cyclists rode at three pre-determined work intensities set at a proportion of their maximal oxygen consumption (VO2max): (1) below lactate threshold [work load that produces a VO2 which is 10% less than the lactate threshold VO2 (sub-LT)], (2) lactate threshold VO2 (LT), and (3) above lactate threshold [workload that produces a VO2 which is 10% greater than lactate threshold VO2 (supra-LT)], and equated across exercise modes on the basis of fc. Voltage signals from the crank arm were recorded as FM signals for subsequent representation of peak and average force. Open circuit VO2 measurements were done in the field by Douglas bag gas collection and in the laboratory by automated gas collection and analysis. fc was recorded with a telemeter (Polar Electro Sport Tester, PE3000). Significant differences (P < 0.05) were observed: (1) in VO2 between FC and both laboratory conditions at sub-LT intensity and LT intensities, (2) in peak force between FC and TC at sub-LT intensity, (3) in average force between FC and RE at sub-LT. No significant differences were demonstrated at supra-LT intensity for VO2. Similarly no significant differences were observed in peak and average force for either LT or supra-LT intensities. These data indicate that equating work intensities on the basis of fc measured in laboratory conditions would overestimate the VO2 which would be generated in the field and conversely, that using fc measured in the laboratory to establish field work intensity would underestimate mechanical workload experienced in the field.

  14. Synthesis of Bi2S3/BiVO4 Heterojunction with a One-Step Hydrothermal Method Based on pH Control and the Evaluation of Visible-Light Photocatalytic Performance

    PubMed Central

    Zhao, Deqiang; Wang, Wenwen; Zong, Wenjuan; Xiong, Shimin; Zhang, Qian; Ji, Fangying; Xu, Xuan

    2017-01-01

    The band gaps of bismuth vanadate (BiVO4) and bismuth sulfide (Bi2S3) are about 2.40 eV and 1.30 eV, respectively. Although both BiVO4 and Bi2S3 are capable of strong visible light absorption, electron–hole recombination occurs easily. To solve this problem, we designed a one-step hydrothermal method for synthesizing a Bismuth sulfide (Bi2S3)/Bismuth vanadate (BiVO4) heterojunction using polyvinylpyrrolidone K-30 (PVP) as a structure-directing agent, and 2-Amino-3-mercaptopropanoic acid (l-cysteine) as a sulfur source. The pH of the reaction solution was regulated to yield different products: when the pH was 7.5, only monoclinic BiVO4 was produced (sample 7.5); when the pH was 8.0 or 8.5, both Bi2S3 and BiVO4 were produced (samples 8.0 and 8.5); and when the pH was 9.0, only Bi2S3 was produced (sample 9.0). In sample 8.0, Bi2S3 and BiVO4 were closely integrated with each other, with Bi2S3 particles formed on the surface of concentric BiVO4 layers, but the two compounds grew separately in a pH solution of 8.5. Visible-light photocatalytic degradation experiments demonstrated that the degradation efficiency of the Bi2S3/BiVO4 heterojunction was highest when prepared under a pH of 8.0. The initial rhodamine B in the solution (5 mg/L) was completely degraded within three hours. Recycling experiments verified the high stability of Bi2S3/BiVO4. The synthesis method proposed in this paper is expected to enable large-scale and practical use of Bi2S3/BiVO4. PMID:28767085

  15. Naturally formed ultrathin V2O5 heteroepitaxial layer on VO2/sapphire(001) film

    NASA Astrophysics Data System (ADS)

    Littlejohn, Aaron J.; Yang, Yunbo; Lu, Zonghuan; Shin, Eunsung; Pan, KuanChang; Subramanyam, Guru; Vasilyev, Vladimir; Leedy, Kevin; Quach, Tony; Lu, Toh-Ming; Wang, Gwo-Ching

    2017-10-01

    Vanadium dioxide (VO2) and vanadium pentoxide (V2O5) thin films change their properties in response to external stimuli such as photons, temperature, electric field and magnetic field and have applications in electronics, optical devices, and sensors. Due to the multiple valence states of V and non-stoichiometry in thin films, it is challenging to grow epitaxial, single-phase V-oxide on a substrate, or a heterostructure of two epitaxial V-oxides. We report the formation of a heterostructure consisting of a few nm thick ultrathin V2O5 epitaxial layer on pulsed laser deposited tens of nm thick epitaxial VO2 thin films grown on single crystal Al2O3(001) substrates without post annealing of the VO2 film. The simultaneous observation of the ultrathin epitaxial V2O5 layer and VO2 epitaxial film is only possible by our unique reflection high energy electron diffraction pole figure analysis. The out-of-plane and in-plane epitaxial relationships are V2O5[100]||VO2[010]||Al2O3[001] and V2O5[03 2 bar ]||VO2[100]||Al2O3[1 1 bar 0], respectively. The existence of the V2O5 layer on the surface of the VO2 film is also supported by X-ray photoelectron spectroscopy and Raman spectroscopy.

  16. Energy system contributions in middle-distance running events.

    PubMed

    Hill, D W

    1999-06-01

    The aim of this study was to estimate the energy contributions in middle-distance running events for male and female university athletes. The oxygen uptake (VO2) response during high-speed running was measured directly during exhaustive treadmill tests. Muscle mass was estimated using anthropometry. Each athlete completed an average of three races over 400 m, 800 m or 1500 m. Five minutes after each race, they provided a blood sample for determination of blood lactate concentration. For each race, energy cost, which was expressed as oxygen equivalents, was calculated as the sum of the aerobic and anaerobic components. The aerobic contribution was calculated as the sum of oxygen stores (2.3 ml O2.kg body mass-1) and total VO2 (based on the VO2 response to treadmill running). The anaerobic contribution was calculated as the sum of the energy available from phosphocreatine stores (37 ml O2.kg muscle mass-1) and the energy from glycolysis (3.0 ml O2.kg body mass-1 per mmol.l-1 increase in blood lactate concentration). For the women, the anaerobic energy contributions for the 400 m, 800 m and 1500 m averaged 62%, 33% and 17%, respectively. For the men, the anaerobic contributions averaged 63%, 39% and 20%, respectively. This information will help coaches and sport scientists to design and implement individualized training programmes.

  17. Temperature-dependent changes in the viscoelasticity of intact resting mammalian (rat) fast- and slow-twitch muscle fibres.

    PubMed

    Mutungi, G; Ranatunga, K W

    1998-04-01

    1. The tension and sarcomere length responses induced by ramp stretches (at amplitudes of 1-3 % fibre length (Lo) and speeds of 0.01-12 Lo s-1) were examined at different temperatures (range, 10-35 degrees C) in resting intact muscle fibre bundles isolated from the soleus (a slow-twitch muscle) and extensor digitorum longus (a fast-twitch muscle) of the rat. Some observations are also presented on the effects of chemical skinning on passive viscoelasticity at 10 degrees C. 2. As previously reported, the tension response to a ramp stretch, in different preparations and under various conditions, could be resolved into a viscous (P1), a viscoelastic (P2) and an elastic (P3) component and showed characteristic differences between slow and fast muscle fibres. 3. Chemical skinning of the muscle fibres led to a decrease in the amplitude of all three tension components. However, the fast-slow fibre differences remained after skinning. For example, the viscosity coefficient derived from P1 tension data decreased from 0.84 +/- 0.06 before skinning to 0.44 +/- 0.06 kN s m-2 after skinning in fast fibres; the corresponding values in slow fibres were 2.1 +/- 0.08 and 0.87 +/- 0.09 kN s m-2, respectively. 4. Increasing the experimental temperature from 10 to 35 degrees C led to a decrease in all the tension components in both fast and slow muscle fibre bundles. The decrease of P1 (viscous) tension was such that the viscosity coefficient calculated using P1 data was reduced from 0.84 +/- 0.1 to 0.43 +/- 0.05 kN s m-2 in fast fibres and from 2.0 +/- 0.1 to 1.0 +/- 0.1 kN s m-2 in slow fibres (Q10 of approximately 1.3 in both). 5. In both fast and slow muscle fibre preparations, the plateau tension of the viscoelastic component (P2) decreased by 60-80 % as the temperature was increased from 10 to 35 degrees C giving P2 tension a Q10 of approximately 1.4 in slow fibres and approximately 1.7 in the fast fibres. Additionally, the relaxation time of the viscoelasticity decreased from 11.9 +/- 1 ms (fast) and 43.1 +/- 1 ms (slow) at 10 degrees C to 3 +/- 0.5 ms (fast) at 25 C degrees and 8. 7 +/- 0.6 ms (slow) at 35 degrees C (Q10 of approximately 2.0 in slow and approximately 2.5 in fast fibres). 6. The fast-slow fibre differences in passive viscoelasticity remained at the high physiological temperatures. The physiological significance of such fibre-type differences and their possible underlying mechanisms are discussed.

  18. Overspeed HIIT in Lower-Body Positive Pressure Treadmill Improves Running Performance.

    PubMed

    Gojanovic, Boris; Shultz, Rebecca; Feihl, Francois; Matheson, Gordon

    2015-12-01

    Optimal high-intensity interval training (HIIT) regimens for running performance are unknown, although most protocols result in some benefit to key performance factors (running economy (RE), anaerobic threshold (AT), or maximal oxygen uptake (VO2max)). Lower-body positive pressure (LBPP) treadmills offer the unique possibility to partially unload runners and reach supramaximal speeds. We studied the use of LBPP to test an overspeed HIIT protocol in trained runners. Eleven trained runners (35 ± 8 yr, VO2max, 55.7 ± 6.4 mL·kg⁻¹·min⁻¹) were randomized to an LBPP (n = 6) or a regular treadmill (CON, n = 5), eight sessions over 4 wk of HIIT program. Four to five intervals were run at 100% of velocity at VO2max (vVO2max) during 60% of time to exhaustion at vVO2max (Tlim) with a 1:1 work:recovery ratio. Performance outcomes were 2-mile track time trial, VO2max, vVO2max, vAT, Tlim, and RE. LBPP sessions were carried out at 90% body weight. Group-time effects were present for vVO2max (CON, 17.5 vs. 18.3, P = 0.03; LBPP, 19.7 vs. 22.3 km·h⁻¹; P < 0.001) and Tlim (CON, 307.0 vs. 404.4 s, P = 0.28; LBPP, 444.5 vs. 855.5, P < 0.001). Simple main effects for time were present for field performance (CON, -18; LBPP, -25 s; P = 0.002), VO2max (CON, 57.6 vs. 59.6; LBPP, 54.1 vs. 55.1 mL·kg⁻¹·min⁻¹; P = 0.04) and submaximal HR (157.7 vs. 154.3 and 151.4 vs. 148.5 bpm; P = 0.002). RE was unchanged. A 4-wk HIIT protocol at 100% vVO2max improves field performance, vVO2max, VO2max and submaximal HR in trained runners. Improvements are similar if intervals are run on a regular treadmill or at higher speeds on a LPBB treadmill with 10% body weight reduction. LBPP could provide an alternative for taxing HIIT sessions.

  19. A comparison of the shuttle and 6 minute walking tests with measured peak oxygen consumption in patients with heart failure.

    PubMed

    Green, D J; Watts, K; Rankin, S; Wong, P; O'Driscoll, J G

    2001-09-01

    This study investigated the use of an incremental, externally-paced 10 m shuttle walk test (SWT) as an objective, reliable and predictive test of functional capacity in patients with heart failure (CHF). The SWT was compared to a 6 minute walk test (6WT) and a maximal symptom-limited treadmill peak oxygen consumption (VO2peak) test. Experiment 1 examined the reproducibility of the SWT. Two SWF trials were performed and distance ambulated (DA), heart rate (HR) and rate of perceived exertion (RPE) results compared. In experiment 2, SWT, 6WT, and VO2 peak tests were performed and HR. RPE and ambulatory VO2 compared. The SWT demonstrated strong test/retest reliability for DA (r = 0.98). HR (r = 0.96) and RPE (r = 0.89). Treadmill VO2 peak was significantly correlated with DA during the SWT (r = 0.83, P < 0.05), but not the 6WT. SWT peak VO2 (18.5 +/- 1.8 ml.kg(-1) x min(-1)) and treadmill VO2 peak (18.3 +/-2.0 ml.kg(-1) x min(-1)) were also highly correlated (r = 0.78, P < 0.05). Conversely, 6WT peak VO2 and treadmill VO2 peak were not significantly correlated. This study suggests the SWT is a reliable, objective test, highly predictive of VO2 peak which may be a more optimal field exercise test than the self paced 6WT.

  20. C=C bond cleavage on neutral VO3(V2O5)n clusters.

    PubMed

    Dong, Feng; Heinbuch, Scott; Xie, Yan; Bernstein, Elliot R; Rocca, Jorge J; Wang, Zhe-Chen; Ding, Xun-Lei; He, Sheng-Gui

    2009-01-28

    The reactions of neutral vanadium oxide clusters with alkenes (ethylene, propylene, 1-butene, and 1,3-butadiene) are investigated by experiments and density function theory (DFT) calculations. Single photon ionization through extreme ultraviolet radiation (EUV, 46.9 nm, 26.5 eV) is used to detect neutral cluster distributions and reaction products. In the experiments, we observe products (V(2)O(5))(n)VO(2)CH(2), (V(2)O(5))(n)VO(2)C(2)H(4), (V(2)O(5))(n)VO(2)C(3)H(4), and (V(2)O(5))(n)VO(2)C(3)H(6), for neural V(m)O(n) clusters in reactions with C(2)H(4), C(3)H(6), C(4)H(6), and C(4)H(8), respectively. The observation of these products indicates that the C=C bonds of alkenes can be broken on neutral oxygen rich vanadium oxide clusters with the general structure VO(3)(V(2)O(5))(n=0,1,2...). DFT calculations demonstrate that the reaction VO(3) + C(3)H(6) --> VO(2)C(2)H(4) + H(2)CO is thermodynamically favorable and overall barrierless at room temperature. They also provide a mechanistic explanation for the general reaction in which the C=C double bond of alkenes is broken on VO(3)(V(2)O(5))(n=0,1,2...) clusters. A catalytic cycle for alkene oxidation on vanadium oxide is suggested based on our experimental and theoretical investigations. The reactions of V(m)O(n) with C(6)H(6) and C(2)F(4) are also investigated by experiments. The products VO(2)(V(2)O(5))(n)C(6)H(4) are observed for dehydration reactions between V(m)O(n) clusters and C(6)H(6). No product is detected for V(m)O(n) clusters reacting with C(2)F(4). The mechanisms of the reactions between VO(3) and C(2)F(4)/C(6)H(6) are also investigated by calculations at the B3LYP/TZVP level.

  1. Effect of BMI, Body Fat Percentage and Fat Free Mass on Maximal Oxygen Consumption in Healthy Young Adults.

    PubMed

    Mondal, Himel; Mishra, Snigdha Prava

    2017-06-01

    Maximal oxygen consumption (VO 2max ) is an important measure of cardiorespiratory capacity of an individual at a given degree of fitness and oxygen availability. Risk of cardiovascular diseases increases with increasing degree of obesity and a low level of VO 2max has been established as an independent risk factor for cardiovascular mortality. To determine VO 2max in young adults and to find its correlation with Body Mass Index (BMI), Body Fat% and Fat Free Mass (FFM). Fifty four (male=30, female=24) healthy young adults of age group18-25 years after screening by Physical Activity Readiness Questionnaire (PAR-Q) participated in the study. Height was measured by stadiometer. Weight was measured by digital weighing scale with 0.1 kg sensitivity. Body fat% was measured by Bioelectrical Impedance Analysis (BIA) method. FFM was calculated by subtracting fat mass from the body weight. VO 2max (mL.kg -1 .min -1 ) was obtained by Submaximal Exercise Test (SET) by first two stages of Bruce Protocol with the basis of linear relationship between Heart Rate (HR) and oxygen consumption (VO 2 ). Data were analysed statistically in GraphPad Prism software version 6.01 for windows. VO 2max (mL.kg -1 .min -1 ) of male (43.25±7.25) was significantly (p<0.001) higher than female (31.65±2.10). BMI showed weak negative correlation (r= -0.3232, p=0.0171) with VO 2max but Body Fat% showed strong negative correlation (r= -0.7505, p<0.001) with VO 2max . FFM positively correlated (r=0.3727, p=0.0055) with VO 2max . Increased body fat is associated with decreased level of VO 2max in young adults. Obesity in terms of Fat% is a better parameter than BMI for prediction of low VO 2max .

  2. VO{sub 2} (A): Reinvestigation of crystal structure, phase transition and crystal growth mechanisms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rao Popuri, Srinivasa; University of Bordeaux, ICMCB, UPR 9048, F-33608 Pessac; National Institute for Research and Development in Electrochemistry and Condensed Matter, Timisoara, Plautius Andronescu Str. No. 1, 300224 Timisoara

    2014-05-01

    Well crystallized VO{sub 2} (A) microrods were grown via a single step hydrothermal reaction in the presence of V{sub 2}O{sub 5} and oxalic acid. With the advantage of high crystalline samples, we propose P4/ncc as an appropriate space group at room temperature. From morphological studies, we found that the oriented attachment and layer by layer growth mechanisms are responsible for the formation of VO{sub 2} (A) micro rods. The structural and electronic transitions in VO{sub 2} (A) are strongly first order in nature, and a marked difference between the structural transition temperatures and electronic transitions temperature was evidenced. The reversiblemore » intra- (LTP-A to HTP-A) and irreversible inter- (HTP-A to VO{sub 2} (M1)) structural phase transformations were studied by in-situ powder X-ray diffraction. Attempts to increase the size of the VO{sub 2} (A) microrods are presented and the possible formation steps for the flower-like morphologies of VO{sub 2} (M1) are described. - Graphical abstract: Using a single step and template free hydrothermal synthesis, well crystallized VO{sub 2} (A) microrods were prepared and the P4/ncc space group was assigned to the room temperature crystal structure. Reversible and irreversible phase transitions among different VO{sub 2} polymorphs were identified and their progressive nature was highlighted. Attempts to increase the microrods size, involving layer by layer formation mechanisms, are presented. - Highlights: • Highly crystallized VO{sub 2} (A) microrods were grown via a single step hydrothermal process. • The P4/ncc space group was determined for VO{sub 2} (A) at room temperature. • The electronic structure and progressive nature of the structural phase transition were investigated. • A weak coupling between structural and electronic phase transitions was identified. • Different crystallite morphologies were discussed in relation with growth mechanisms.« less

  3. Verification testing to confirm VO2max attainment in persons with spinal cord injury.

    PubMed

    Astorino, Todd A; Bediamol, Noelle; Cotoia, Sarah; Ines, Kenneth; Koeu, Nicolas; Menard, Natasha; Nyugen, Brianna; Olivo, Cassandra; Phillips, Gabrielle; Tirados, Ardreen; Cruz, Gabriela Velasco

    2018-01-22

    Maximal oxygen uptake (VO 2 max) is a widely used measure of cardiorespiratory fitness, aerobic function, and overall health risk. Although VO 2 max has been measured for almost 100 yr, no standardized criteria exist to verify VO 2 max attainment. Studies document that incidence of 'true' VO 2 max obtained from incremental exercise (INC) can be confirmed using a subsequent verification test (VER). In this study, we examined efficacy of VER in persons with spinal cord injury (SCI). Repeated measures, within-subjects study. University laboratory in San Diego, CA. Ten individuals (age and injury duration = 33.3 ± 10.5 yr and 6.8 ± 6.2 yr) with SCI and 10 able-bodied (AB) individuals (age = 24.1 ± 7.4 yr). Peak oxygen uptake (VO 2 peak) was determined during INC on an arm ergometer followed by VER at 105 percent of peak power output (% PPO). Gas exchange data, heart rate (HR), and blood lactate concentration (BLa) were measured during exercise. Across all participants, VO 2 peak was highly related between protocols (ICC = 0.98) and the mean difference was equal to 0.08 ± 0.11 L/min. Compared to INC, VO 2 peak from VER was not different in SCI (1.30 ± 0.45 L/min vs. 1.31 ± 0.43 L/min) but higher in AB (1.63 ± 0.40 L/min vs. 1.76 ± 0.40 L/min). Data show similar VO 2 peak between incremental and verification tests in SCI, suggesting that VER confirms VO 2 max attainment. However, in AB participants completing arm ergometry, VER is essential to validate appearance of 'true' VO 2 peak.

  4. Nanostructured Electrocatalysts for All-Vanadium Redox Flow Batteries.

    PubMed

    Park, Minjoon; Ryu, Jaechan; Cho, Jaephil

    2015-10-01

    Vanadium redox reactions have been considered as a key factor affecting the energy efficiency of the all-vanadium redox flow batteries (VRFBs). This redox reaction determines the reaction kinetics of whole cells. However, poor kinetic reversibility and catalytic activity towards the V(2+)/V(3+) and VO(2+)/VO2(+) redox couples on the commonly used carbon substrate limit broader applications of VRFBs. Consequently, modified carbon substrates have been extensively investigated to improve vanadium redox reactions. In this Focus Review, recent progress on metal- and carbon-based nanomaterials as an electrocatalyst for VRFBs is discussed in detail, without the intention to provide a comprehensive review on the whole components of the system. Instead, the focus is mainly placed on the redox chemistry of vanadium ions at a surface of various metals, different dimensional carbons, nitrogen-doped carbon nanostructures, and metal-carbon composites. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Thermal Instability Induced Oriented 2D Pores for Enhanced Sodium Storage.

    PubMed

    Kong, Lingjun; Xie, Chen-Chao; Gu, Haichen; Wang, Chao-Peng; Zhou, Xianlong; Liu, Jian; Zhou, Zhen; Li, Zhao-Yang; Zhu, Jian; Bu, Xian-He

    2018-04-19

    Hierarchical porous structures are highly desired for various applications. However, it is still challenging to obtain such materials with tunable architectures. Here, this paper reports hierarchical nanomaterials with oriented 2D pores by taking advantages of thermally instable bonds in vanadium-based metal-organic frameworks (MOFs). High-temperature calcination of these MOFs accompanied by the loss of coordinated water molecules and other components enables the formation of orderly slit-like 2D pores in vanadium oxide/porous carbon nanorods (VO x /PCs). This unique combination leads to an increase of the reactive surface area. In addition, optimized VO x /PCs demonstrate high-rate capability and ultralong cycling life for sodium storage. The assembled full cells also show high capacity and cycling stability. This report provides an effective strategy for producing MOFs-derived composites with hierarchical porous architectures for energy storage. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Hydrothermal growth of VO2 nanoplate thermochromic films on glass with high visible transmittance

    PubMed Central

    Zhang, Jiasong; Li, Jingbo; Chen, Pengwan; Rehman, Fida; Jiang, Yijie; Cao, Maosheng; Zhao, Yongjie; Jin, Haibo

    2016-01-01

    The preparation of thermochromic vanadium dioxide (VO2) films in an economical way is of interest to realizing the application of smart windows. Here, we reported a successful preparation of self-assembly VO2 nanoplate films on TiO2-buffered glass by a facile hydrothermal process. The VO2 films composed of triangle-shaped plates standing on substrates exhibit a self-generated porous structure, which favors the transmission of solar light. The porosity of films is easily controlled by changing the concentration of precursor solutions. Excellent thermochromic properties are observed with visible light transmittance as high as 70.3% and solar modulating efficiency up to 9.3% in a VO2 film with porosity of ~35.9%. This work demonstrates a promising technique to promote the commercial utilization of VO2 in smart windows. PMID:27296772

  7. Factors affecting oxygen consumption in wild-caught yellow-bellied marmots (Marmota flaviventris).

    PubMed

    Armitage, K B; Salsbury, C M

    1992-12-01

    1. All age groups gained mass during the active season, but mass-gain of adult females was delayed during lactation. 2. The relationship of body mass to metabolic rate varied widely; when the relationship was significant, R2 varied from 10.3 to 72.6%. Body mass affects VO2 more during lactation than at any other period. 3. Mean VO2 of adult males was higher in June than that of adult, non-lactating females. 4. VO2 of reproductive females was significantly higher during lactation than during gestation or postlactation because specific VO2 varied. Specific VO2 of non-reproductive females declined over the active season. 5. Specific VO2 of all age groups declined between the premolt and postmolt periods. The reduced maintenance costs can contribute 20-46% to daily growth. 6. Observed VO2 was lower than the value predicted from intraspecific or interspecific Bm:M regressions. 7. VO2 of wild-caught marmots was lower than that of marmots maintained in the laboratory, probably because of dietary differences. 8. Because basal metabolism is a stage on a food-deprivation curve, we suggest that basal metabolic rate is not an appropriate measure of the metabolic activity of free-ranging animals.

  8. Oxygen uptake kinetics and exercise capacity in children with cystic fibrosis.

    PubMed

    Fielding, Jeremy; Brantley, Lucy; Seigler, Nichole; McKie, Katie T; Davison, Gareth W; Harris, Ryan A

    2015-07-01

    Exercise capacity, an objective measure of exercise intolerance, is known to predict quality of life and mortality in cystic fibrosis (CF). The mechanisms for exercise intolerance in patients with cystic fibrosis (CF), however, have yet to be fully elucidated. Accordingly, this study sought to investigate oxygen uptake kinetics and the impact of fat-free mass (FFM) on exercise capacity in young patients with CF. 16 young patients with CF (age 13 ± 4 years; 10 female) and 15 matched controls (age 14 ± 3 years; nine female) participated. Pulmonary function and a maximal exercise test on a cycle ergometer using the Godfrey protocol were performed. Exercise capacity (VO2 peak), VO2 response time (VO2 RT), and functional VO2 gain (ΔVO2 /ΔWR) were all determined. Lung function was the only demographic parameter significantly lower (P < 0.05) in CF compared to controls. Exercise capacity was lower in CF (P < 0.014) only when VO2 peak was normalized for FFM (43.5 ± 7.7 vs. 50.6 ± 7.4 ml/kg-FFM/min) or expressed as % predicted (70.1 ± 14.3 vs. 85.4 ± 16.0%). The VO2 RT was slower (36.1 ± 15.1 vs. 25.0 ± 12.4 sec; P = 0.03) and the ΔVO2 /ΔWR slope was lower (8.4 ± 3 ml/min/watt vs. 10.1 ± 1.4 ml/min/watt; P = 0.02) in patients compared to controls, respectively. In conclusion, a delayed VO2 response time coupled with the lower functional VO2 gain (ΔVO2 /ΔWR) suggest that young patients with CF have impairment in oxygen transport and oxygen utilization by the muscles. These data in addition to differences in VO2 peak normalized for FFM provide some insight that muscle mass and muscle metabolism contribute to exercise intolerance in CF. © 2015 Wiley Periodicals, Inc.

  9. Voltage-Controlled Switching and Thermal Effects in VO2 Nano-Gap Junctions

    DTIC Science & Technology

    2014-06-09

    Voltage-controlled switching and thermal effects in VO2 nano-gap junctions Arash Joushaghani,1 Junho Jeong,1 Suzanne Paradis,2 David Alain,2 J...2014) Voltage-controlled switching in lateral VO2 nano-gap junctions with different gap lengths and thermal properties was investigated. The effect of...indicate that the VO2 phase transition was likely initiated electroni- cally, which was sometimes followed by a secondary thermally-induced transition

  10. Structure, hydrolysis, and diffusion of aqueous vanadium ions from Car-Parrinello molecular dynamics

    NASA Astrophysics Data System (ADS)

    Jiang, Zhen; Klyukin, Konstantin; Alexandrov, Vitaly

    2016-09-01

    A molecular level understanding of the properties of electroactive vanadium species in aqueous solution is crucial for enhancing the performance of vanadium redox flow batteries. Here, we employ Car-Parrinello molecular dynamics simulations based on density functional theory to investigate the hydration structures, first hydrolysis reaction, and diffusion of aqueous V2+, V3+, VO2+, and VO 2+ ions at 300 K. The results indicate that the first hydration shell of both V2+ and V3+ contains six water molecules, while VO2+ is coordinated to five and VO 2+ to three water ligands. The first acidity constants (pKa) estimated using metadynamics simulations are 2.47, 3.06, and 5.38 for aqueous V3+, VO 2+ , and VO2+, respectively, while V2+ is predicted to be a fairly weak acid in aqueous solution with a pKa value of 6.22. We also show that the presence of chloride ions in the first coordination sphere of the aqueous VO 2+ ion has a significant impact on water hydrolysis leading to a much higher pKa value of 4.8. This should result in a lower propensity of aqueous VO 2+ for oxide precipitation reaction in agreement with experimental observations for chloride-based electrolyte solutions. The computed diffusion coefficients of vanadium species in water at room temperature are found to increase as V 3 + < VO 2 + < V O 2 + < V 2 + and thus correlate with the simulated hydrolysis constants, namely, the higher the pKa value, the greater the diffusion coefficient.

  11. Facile Phase Control of Multivalent Vanadium Oxide Thin Films (V2O5 and VO2) by Atomic Layer Deposition and Postdeposition Annealing.

    PubMed

    Song, Gwang Yeom; Oh, Chadol; Sinha, Soumyadeep; Son, Junwoo; Heo, Jaeyeong

    2017-07-19

    Atomic layer deposition was adopted to deposit VO x thin films using vanadyl tri-isopropoxide {VO[O(C 3 H 7 )] 3 , VTIP} and water (H 2 O) at 135 °C. The self-limiting and purge-time-dependent growth behaviors were studied by ex situ ellipsometry to determine the saturated growth conditions for atomic-layer-deposited VO x . The as-deposited films were found to be amorphous. The structural, chemical, and optical properties of the crystalline thin films with controlled phase formation were investigated after postdeposition annealing at various atmospheres and temperatures. Reducing and oxidizing atmospheres enabled the formation of pure VO 2 and V 2 O 5 phases, respectively. The possible band structures of the crystalline VO 2 and V 2 O 5 thin films were established. Furthermore, an electrochemical response and a voltage-induced insulator-to-metal transition in the vertical metal-vanadium oxide-metal device structure were observed for V 2 O 5 and VO 2 films, respectively.

  12. Peak oxygen consumption measured during the stair-climbing test in lung resection candidates.

    PubMed

    Brunelli, Alessandro; Xiumé, Francesco; Refai, Majed; Salati, Michele; Di Nunzio, Luca; Pompili, Cecilia; Sabbatini, Armando

    2010-01-01

    The stair-climbing test is commonly used in the preoperative evaluation of lung resection candidates, but it is difficult to standardize and provides little physiologic information on the performance. To verify the association between the altitude and the V(O2peak) measured during the stair-climbing test. 109 consecutive candidates for lung resection performed a symptom-limited stair-climbing test with direct breath-by-breath measurement of V(O2peak) by a portable gas analyzer. Stepwise logistic regression and bootstrap analyses were used to verify the association of several perioperative variables with a V(O2peak) <15 ml/kg/min. Subsequently, multiple regression analysis was also performed to develop an equation to estimate V(O2peak) from stair-climbing parameters and other patient-related variables. 56% of patients climbing <14 m had a V(O2peak) <15 ml/kg/min, whereas 98% of those climbing >22 m had a V(O2peak) >15 ml/kg/min. The altitude reached at stair-climbing test resulted in the only significant predictor of a V(O2peak) <15 ml/kg/min after logistic regression analysis. Multiple regression analysis yielded an equation to estimate V(O2peak) factoring altitude (p < 0.0001), speed of ascent (p = 0.005) and body mass index (p = 0.0008). There was an association between altitude and V(O2peak) measured during the stair-climbing test. Most of the patients climbing more than 22 m are able to generate high values of V(O2peak) and can proceed to surgery without any additional tests. All others need to be referred for a formal cardiopulmonary exercise test. In addition, we were able to generate an equation to estimate V(O2peak), which could assist in streamlining the preoperative workup and could be used across different settings to standardize this test. Copyright (c) 2010 S. Karger AG, Basel.

  13. The Effect of Habitual Smoking on VO2max

    NASA Technical Reports Server (NTRS)

    Wier, Larry T.; Suminski, Richard R.; Poston, Walker S.; Randles, Anthony M.; Arenare, Brian; Jackson, Andrew S.

    2008-01-01

    VO2max is associated with many factors, including age, gender, physical activity, and body composition. It is popularly believed that habitual smoking lowers aerobic fitness. PURPOSE: to determine the effect of habitual smoking on VO2max after controlling for age, gender, activity and BMI. METHODS: 2374 men and 375 women employed at the NASA/Johnson Space Center were measured for VO2max by indirect calorimetry (RER>=1.1), activity by the 11 point (0-10) NASA Physical Activity Status Scale (PASS), BMI and smoking pack-yrs (packs day*y of smoking). Age was recorded in years and gender was coded as M=1, W=0. Pack.y was made a categorical variable consisting of four levels as follows: Never Smoked (0), Light (1-10), Regular (11-20), Heavy (>20). Group differences were verified by ANOVA. A General Linear Models (GLM) was used to develop two models to examine the relationship of smoking behavior on VO2max. GLM #1(without smoking) determined the combined effects of age, gender, PASS and BMI on VO2max. GLM #2 (with smoking) determined the added effects of smoking (pack.y groupings) on VO2max after controlling for age, gender, PASS and BMI. Constant errors (CE) were calculated to compare the accuracy of the two models for estimating the VO2max of the smoking subgroups. RESULTS: ANOVA affirmed the mean VO2max of each pack.y grouping decreased significantly (p<0.01) as the level of smoking exposure increased. GLM #1 showed that age, gender, PASS and BMI were independently related with VO2max (R2 = 0.642, SEE = 4.90, p<0.001). The added pack.y variables in GLM #2 were statistically significant (R2 change = 0.7%, p<0.01). Post hoc analysis showed that compared to Never Smoked, the effects on VO2max from Light and Regular smoking habits were -0.83 and -0.85 ml.kg- 1.min-1 respectively (p<0.05). The effect of Heavy smoking on VO2max was -2.56 ml.kg- 1.min-1 (p<0.001). The CE s of each smoking group in GLM #2 was smaller than the CE s of the smoking group counterparts in GLM #1. CONCLUSIONS: After accounting for the effects of gender, age, PASS and BMI the effect of habitual smoking on reducing VO2max is minimal, about 0.85 ml/kg/min, until the habit exceeds 20 pack.y at which point an additional decrease of 1.71 ml/kg/min is noted. Adding pack.y data improves the accuracy of predicting the VO2max of smokers.

  14. Comparison of distribution and toxicity following repeated oral dosing of different vanadium oxide nanoparticles in mice.

    PubMed

    Park, Eun-Jung; Lee, Gwang-Hee; Yoon, Cheolho; Kim, Dong-Wan

    2016-10-01

    Vanadium is an important ultra-trace element derived from fuel product combustion. With the development of nanotechnology, vanadium oxide nanoparticles (VO NPs) have been considered for application in various fields, thus the possibility of release into the environment and human exposure is also increasing. Considering that verification of bioaccumulation and relevant biological responses are essential for safe application of products, in this study, we aimed to identify the physicochemical properties that determine their health effects by comparing the biological effects and tissue distribution of different types of VO NPs in mice. For this, we prepared five types of VO NPs, commercial (C)-VO2 and -V2O5 NPs and synthetic (S)-VO2, -V2O3, and -V2O5 NPs. While the hydrodynamic diameter of the two types of C-VO NPs was irregular and impossible to measure, those of the three types of S-VO NPs was in the range of 125-170nm. The S- and C-V2O5 NPs showed higher dissolution rates compared to other VO NPs. We orally dosed the five types of VO NPs (70 and 210μg/mouse, approximately 2 and 6mg/kg) to mice for 28 days and compared their biodistribution and toxic effects. We found that S-V2O5 and S-V2O3 NPs more accumulated in tissues compared to other three types of VO NPs, and the accumulated level was in order of heart>liver>kidney>spleen. Additionally, tissue levels of redox reaction-related elements and electrolytes (Na(+), K(+), and Ca(2+)) were most clearly altered in the heart of treated mice. Notably, all S- and C-VO NPs decreased the number of WBCs at the higher dose, while total protein and albumin levels were reduced at the higher dose of S-V2O5 and S-V2O3 NPs. Taken together, we conclude that the biodistribution and toxic effects of VO NPs depend on their dissolution rates and size (surface area). Additionally, we suggest that further studies are needed to clarify effects of VO NPs on functions of the heart and the immune system. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Resistance modulation in VO2 nanowires induced by an electric field via air-gap gates

    NASA Astrophysics Data System (ADS)

    Kanki, Teruo; Chikanari, Masashi; Wei, Tingting; Tanaka, Hidekazu; The Institute of Scientific; Industrial Research Team

    Vanadium dioxide (VO2) shows huge resistance change with metal-insulator transition (MIT) at around room temperature. Controlling of the MIT by applying an electric field is a topical ongoing research toward the realization of Mott transistor. In this study, we have successfully switched channel resistance of VO2 nano-wire channels by a pure electrostatic field effect using a side-gate-type field-effect transistor (SG-FET) viaair gap and found that single crystalline VO2 nanowires and the channels with narrower width enhance transport modulation rate. The rate of change in resistance ((R0-R)/R, where R0 and R is the resistance of VO2 channel with off state and on state gate voltage (VG) , respectively) was 0.42 % at VG = 30 V in in-plane poly-crystalline VO2 channels on Al2O3(0001) substrates, while the rate in single crystalline channels on TiO2 (001) substrates was 3.84 %, which was 9 times higher than that using the poly-crystalline channels. With reducing wire width from 3000 nm to 400 nm of VO2 on TiO2 (001) substrate, furthermore, resistance modulation ratio enhanced from 0.67 % to 3.84 %. This change can not be explained by a simple free-electron model. In this presentation, we will compare the electronic properties between in-plane polycrystalline VO2 on Al2O3 (0001) and single crystalline VO2 on TiO2 (001) substrates, and show experimental data in detail..

  16. Relationship between percentages of heart rate reserve and oxygen uptake reserve during cycling and running: a validation study.

    PubMed

    Guimarães, Giovanna C; Farinatti, Paulo T V; Midgley, Adrian W; Vasconcellos, Fabrício; Vigário, Patrícia; Cunha, Felipe A

    2017-06-22

    The present study investigated the relationship between percentages of heart rate reserve (%HRR) and oxygen uptake reserve (%VO2R) during a cardiopulmonary exercise test (CPET) and discrete bouts of isocaloric cycling and treadmill running. Thirty men visited the laboratory three times for anthropometrical and resting VO2 assessments, and perform cycling and running CPETs. Ten men visited the laboratory twice more to investigate the validity of the %HRR-%VO2R relationships during isocaloric bouts of cycling and running at 75% VO2R with energy expenditures of 400 kcals. The %HRR was significantly higher than the %VO2R during both CPETs at all exercise intensities (P < 0.001). During isocaloric exercise bouts, mean %HRR-%VO2R differences of 6.5% and 7.0% were observed for cycling and running, respectively (P = 0.007 to P < 0.001). The %HRR and %VO2R increased over time (P < 0.001), the rate of which was influenced by exercise modality (P < 0.001). On average, heart rate was 5 (P = 0.007) and 8 (P < 0.001) beats·min higher than predicted from the second energy expenditure quartile for cycling and running, respectively; however, observed VO2 was lower than predicted during all quartiles for cycling, and the first quartile for running. Consequently, time to achieve the target energy expenditure was greater than predicted (P < 0.01). In conclusion, the %HRR-%VO2R relationship observed during CPET data did not accurately transpose to prolonged isocaloric bouts of cycling and running. Additionally, power outputs and speeds defined by the ACSM equations for cycling and running, respectively, overestimated VO2 and energy expenditure.

  17. Peak Oxygen Uptake during and after Long-duration Space Flight

    NASA Technical Reports Server (NTRS)

    Moore, Alan D., Jr.; Downs, Meghan E.; Lee, Stuart M. C.; Feiveson, Alan H.; Knudsen, Poul; Evetts, Simon N.; Ploutz-Snyder, Lori

    2014-01-01

    Aerobic capacity (VO2peak) previously has not been measured during or after long-duration spaceflight. PURPOSE: To measure VO2peak and submaximal exercise responses during and after International Space Station (ISS) missions. METHODS: Astronauts (9 M, 5 F: 49 +/- 5 yr, 175 +/- 7 cm, 77.2 +/- 15.1 kg, 40.6 +/- 6.4 mL/kg/min [mean +/-SD]) performed graded peak cycle tests 90 days before spaceflight, 15 d (FD15) after launch and every 30 d thereafter during flight, and 1 (R+1), 10 (R+10), and 30 d (R+30) after landing. Oxygen consumption (VO2) and heart rate (HR) were measured from rest to peak exercise, while cardiac output (Q), stroke volume (SV), and arterial-venous oxygen difference (a-vO2diff) were measured only during rest and submaximal exercise. Data were analyzed using mixed-model linear regression. Body mass contributed significantly to statistical models, and thus results are reported as modeled estimates for an average subject. RESULTS: Early inflight (FD15) VO2peak was 17% lower (95% CI = - 22%, -13%) than preflight. VO2peak increased during spaceflight (0.001 L/min/d, P = 0.02) but did not return to preflight levels. On R+1 VO2peak was 15% (95% CI = -19%, -10%) lower than preflight but recovered to within 2% of preflight by R+30 (95% CI = -6%, +3%). Peak HR was not significantly different from preflight at any time. Inflight submaximal VO2 and a-vO2diff were generally lower than preflight, but the Q vs. VO2 slope was unchanged. In contrast, the SV vs. VO2 slope was lower (P < 0.001), primarily due to elevated SV at rest, and the HR vs. VO2 slope was greater (P < 0.001), largely due to elevated HR during more intense exercise. On R+1 although the relationships between VO2 and Q, SV, and HR were not statistically different than preflight, resting and submaximal exercise SV was lower (P < 0.001), resting and submaximal exercise HR was higher (P < 0.002), and a-vO2diff was unchanged. HR and SV returned to preflight levels by R+30. CONCLUSION: In the average astronaut VO2peak was reduced during spaceflight and immediately after landing but factors contributing to lower VO2peak may be different during spaceflight and recovery. Maintaining Q while VO2 is reduced inflight may be suggestive of an elevated blood flow to vascular beds other than exercising muscles, but decreased SV after flight likely reduces Q at peak exertion.

  18. 6-Gingerol Inhibits Growth of Colon Cancer Cell LoVo via Induction of G2/M Arrest

    PubMed Central

    Lin, Ching-Bin; Lin, Chun-Che; Tsay, Gregory J.

    2012-01-01

    6-Gingerol, a natural component of ginger, has been widely reported to possess antiinflammatory and antitumorigenic activities. Despite its potential efficacy against cancer, the anti-tumor mechanisms of 6-gingerol are complicated and remain sketchy. In the present study, we aimed to investigate the anti-tumor effects of 6-gingerol on colon cancer cells. Our results revealed that 6-gingerol treatment significantly reduced the cell viability of human colon cancer cell, LoVo, in a dose-dependent manner. Further flow cytometric analysis showed that 6-gingerol induced significant G2/M phase arrest and had slight influence on sub-G1 phase in LoVo cells. Therefore, levels of cyclins, cyclin-dependent kinases (CDKs), and their regulatory proteins involved in S-G2/M transition were investigated. Our findings revealed that levels of cyclin A, cyclin B1, and CDK1 were diminished; in contrast, levels of the negative cell cycle regulators p27Kip1 and p21Cip1 were increased in response to 6-gingerol treatment. In addition, 6-gingerol treatment elevated intracellular reactive oxygen species (ROS) and phosphorylation level of p53. These findings indicate that exposure of 6-gingerol may induce intracellular ROS and upregulate p53, p27Kip1, and p21Cip1 levels leading to consequent decrease of CDK1, cyclin A, and cyclin B1 as result of cell cycle arrest in LoVo cells. It would be suggested that 6-gingerol should be beneficial to treatment of colon cancer. PMID:22719783

  19. 6-Gingerol Inhibits Growth of Colon Cancer Cell LoVo via Induction of G2/M Arrest.

    PubMed

    Lin, Ching-Bin; Lin, Chun-Che; Tsay, Gregory J

    2012-01-01

    6-Gingerol, a natural component of ginger, has been widely reported to possess antiinflammatory and antitumorigenic activities. Despite its potential efficacy against cancer, the anti-tumor mechanisms of 6-gingerol are complicated and remain sketchy. In the present study, we aimed to investigate the anti-tumor effects of 6-gingerol on colon cancer cells. Our results revealed that 6-gingerol treatment significantly reduced the cell viability of human colon cancer cell, LoVo, in a dose-dependent manner. Further flow cytometric analysis showed that 6-gingerol induced significant G2/M phase arrest and had slight influence on sub-G1 phase in LoVo cells. Therefore, levels of cyclins, cyclin-dependent kinases (CDKs), and their regulatory proteins involved in S-G2/M transition were investigated. Our findings revealed that levels of cyclin A, cyclin B1, and CDK1 were diminished; in contrast, levels of the negative cell cycle regulators p27(Kip1) and p21(Cip1) were increased in response to 6-gingerol treatment. In addition, 6-gingerol treatment elevated intracellular reactive oxygen species (ROS) and phosphorylation level of p53. These findings indicate that exposure of 6-gingerol may induce intracellular ROS and upregulate p53, p27(Kip1), and p21(Cip1) levels leading to consequent decrease of CDK1, cyclin A, and cyclin B1 as result of cell cycle arrest in LoVo cells. It would be suggested that 6-gingerol should be beneficial to treatment of colon cancer.

  20. Microstructures and thermochromic characteristics of VO2/AZO composite films

    NASA Astrophysics Data System (ADS)

    Xiao, Han; Li, Yi; Yuan, Wenrui; Fang, Baoying; Wang, Xiaohua; Hao, Rulong; Wu, Zhengyi; Xu, Tingting; Jiang, Wei; Chen, Peizu

    2016-05-01

    A vanadium dioxide (VO2) thin film was fabricated on a ZnO doped with Al (AZO) conductive glass by magnetron sputtering at room temperature followed by annealing under air atmosphere. The microstructures and optical properties of the thin film were studied. The results showed that the VO2/AZO composite film was poly-crystalline and the AZO layer did not change the preferred growth orientation of VO2. Compared to the VO2 film fabricated on soda-lime glass substrate through the same process and condition, the phase transition temperature of the VO2/AZO composite film was decreased by about 25 °C, thermal hysteresis width narrowed to 6 °C, the visible light transmittance was over 50%, the infrared transmittances before and after phase transition were 21% and 55%, respectively at 1500 nm.

  1. Pacing strategy and VO2 kinetics during a 1500-m race.

    PubMed

    Hanon, C; Leveque, J-M; Thomas, C; Vivier, L

    2008-03-01

    We investigated the oxygen uptake response (V.O (2)) to a 1500-m test conducted using a competition race strategy. On an outdoor track, eleven middle-distance runners performed a test to determine V.O (2max), velocity associated with V.O (2max) (v-V.O (2max)) and a supramaximal 1500-m running test (each test at least two days apart). V.O (2max) response was measured with the use of a miniaturised telemetric gas exchange system (Cosmed, K4, Roma, Italy). The 1500-m running test was performed at a mean velocity of 107. 6 + 2 % v-V.O (2max). The maximal value of oxygen uptake recorded during the 1500-m test (V.O (2peak)) was reached by subjects at 75.9 + 7.5 s (mean + SD) (i.e., 459 +/- 59 m). The time to reach V.O (2max) (TV.O (2peak)) and the start velocity (200- to 400-m after the onset of the 1500 m) expressed in % v-V.O (2max) were negatively and significantly correlated (p < 0.05), but our results indicate that a fast start does not necessarily induce a good performance. These results suggest that V.O (2max) is reached by all the subjects at the onset of a simulated 1500-m running event and are therefore in contrast with previous results obtained during treadmill running.

  2. Luminescence Properties of Self-Activated Mm(VO4)2 (M = Mg, Ca, Sr, and Ba) Phosphors Synthesized by Solid-State Reaction Method.

    PubMed

    Min, Xin; Huang, Zhaohui; Fang, Minghao; Liu, Yan'gai; Tang, Chao; Wu, Xiaowen

    2016-04-01

    In this paper, M3(VO4)2 (M = Mg, Ca, Sr, and Ba) self-activated phosphors were prepared by a solid-state reaction method at 1,000 °C for 5 h. The phase formation and micrographs were analyzed by X-ray diffraction and scanning electron microscopy. The Ca3(VO4)2 phosphor does not show any emission peaks under excitation with ultraviolet (UV) light. However, the M3(VO4)2 (M = Mg, Sr, and Ba) samples are effectively excited by UV light chips ranging from 200 nm to 400 nm and exhibit broad emission bands due to the charge transfer from the oxygen 2p orbital to the vacant 3d orbital of the vanadium in the VO4. The color of these phosphors changes from yellow to light blue via blue-green with increasing ionic radius from Mg to Sr to Ba. The luminescence lifetimes and quantum yield decrease with the increasing unit cell volume and V-V distance, in the order of Mg3(VO4)2 to Sr3(VO4)2 to Ba3(VO4)2. The emission intensity decreases with the increase of temperatures, but presents no color shift. This confirms that these self-activated M3(VO4)2 phosphors can be suggested as candidates of the single-phase phosphors for light using UV light emitting diodes (LEDs).

  3. Preparation and characterization of VO₂(M)-SnO₂ thermochromic films for application as energy-saving smart coatings.

    PubMed

    Li, Wenjing; Ji, Shidong; Qian, Kun; Jin, Ping

    2015-10-15

    Novel VO2(M)/SnO2 heterostructured nanorods are prepared by combining the conventional hydrothermal synthesis method and post annealing process. The results reveal that the nanosized SnO2 particles are not only successfully grown on the surface of the VO2 nanorods but also uniformly distribute on VO2 without aggregation. The existence of the SnO2 nanoparticles inhibits the aggregation during the annealing process and widens the band gap of the VO2 crystals from 0.75 to 1.7 eV. The two aspects can both improve the optical properties of the VO2(M)/SnO2 composite film. The visible transmittance is up to 35.7% and the IR modulation at 2500 nm is more than 56%, which were much higher than the pure VO2(M) film. In addition, the SnO2 layer could reduce the width of the hysteresis from 17.8 to 10.7°C caused by Sn-doping and enhance the sensitivity. We believe that the VO2(M)/SnO2 heterostructured coating is a good candidate for smart windows. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Preparation, Characterization and Thermo-Chromic Properties of EVA/VO2 Laminate Films for Smart Window Applications and Energy Efficiency in Building

    PubMed Central

    Srirodpai, Onruthai; Wootthikanokkhan, Jatuphorn; Nawalertpanya, Saiwan; Yuwawech, Kitti; Meeyoo, Vissanu

    2017-01-01

    Thermochromic films based on vanadium dioxide (VO2)/ethylene vinyl acetate copolymer (EVA) composite were developed. The monoclinic VO2 particles was firstly prepared via hydrothermal and calcination processes. The effects of hydrothermal time and tungsten doping agent on crystal structure and morphology of the calcined metal oxides were reported. After that, 1 wt % of the prepared VO2 powder was mixed with EVA compound, using two different mixing processes. It was found that mechanical properties of the EVA/VO2 films prepared by the melt process were superior to those of which prepared by the solution process. On the other hand, percentage visible light transmittance of the solution casted EVA/VO2 film was greater than that of the melt processed composite film. This was related to the different gel content of EVA rubber and state of dispersion and distribution of VO2 within the polymer matrix phase. Thermochromic behaviors and heat reflectance of the EVA/VO2 film were also verified. In overall, this study demonstrated that it was possible to develop a thermochromic film using the polymer composite approach. In this regard, the mixing condition was found to be one of the most important factors affecting morphology and thermo-mechanical properties of the films. PMID:28772413

  5. Infrared characteristics of VO2 thin films for smart window and laser protection applications

    NASA Astrophysics Data System (ADS)

    Huang, Zhangli; Chen, Sihai; Lv, Chaohong; Huang, Ying; Lai, Jianjun

    2012-11-01

    Vanadium dioxide (VO2) films with a low semiconductor-to-metal transition temperature of 45 °C were fabricated through direct current magnetron sputtering followed by a post-annealing. Atomic force microscopy measurements show that the VO2 grain size is about one hundred of nanometers. Infrared (IR) characteristic is well investigated by applying a He-Ne laser power intensity measurement, and the result reveals that the VO2 film exhibits excellent IR switching property. Furthermore, solar smart window and laser protection experiments demonstrate that the obtained VO2 thin film is a promising material for the application in related fields.

  6. Investigation of properties of the Ca2+ influx and of the Ca2+-activated K+ efflux (Gárdos effect) in vanadate-treated and ATP-depleted human red blood cells.

    PubMed

    Kaiserová, K; Lakatos, B; Peterajová, E; Orlický, J; Varecka, L'

    2002-12-01

    In this study the properties of the 45Ca2+ influx in human red blood cells (RBC) induced by NaVO3 or ATP-depletion were compared. Both NaVO3-induced and ATP-depletion-induced 45Ca2+ influxes were in the range 10(-6)-10(-5) mol Ca2+ x l(-1)cells x h(-1). The saturatability of ATP-depletion-induced 45Ca2+ influx with Ca2+ was much less pronounced than that of NaVO3-induced 45Ca2+ influx. The NaVO3-induced Ca2+ influx was sensitive to nifedipine (IC50 = 50 micromol/l) and Cu2+ (IC50 = 9 micromol/l) but these inhibitors had only a marginal effect when ATP-depletion was used as the Ca2+ influx inducer. On the other hand, polymyxin B (PXB) (1-5 mg/ml) strongly stimulated the ATP-depletion-induced 45Ca2+ influx whereas its effect on the NaVO3-induced Ca2+ influx was biphasic, with about 10% stimulation at lower PXB concentrations and an inhibition of 40% at higher concentrations. SDS-PAGE revealed that both NaVO3 and PXB induced changes in the protein phosphorylation pattern in the presence of Ca2+. NaVO3 stimulated the phosphorylation of several proteins and this effect was counteracted by PXB. The comparison of the kinetics and temperature dependencies of the Gárdos effect induced by NaVO3 and the ATP-depletion showed marked differences. The ability of NaVO3 to induce the Gárdos effect dramatically increased in ATP-depleted cells. These findings indicate that the 45Ca2+ influxes preceding the activation of the Ca2+-activated K+ efflux (Gárdos effect) stimulated by NaVO3 and by ATP-depletion, are mediated by different transport pathways. In addition, obtained results demonstrate that ATP-depletion and NaVO3-treatment exert additive action in triggering the Gárdos effect.

  7. Cardiorespiratory responses to Yo-yo Intermittent Endurance Test in nonelite youth soccer players.

    PubMed

    Castagna, Carlo; Impellizzeri, Franco M; Belardinelli, Romualdo; Abt, Grant; Coutts, Aaron; Chamari, Karim; D'Ottavio, Stefano

    2006-05-01

    This study examined the validity of the Yo-yo Intermittent Endurance Test (Level 1; YYIET) as indicator of aerobic power in youth soccer players. Cardiorespiratory responses were determined in 18 moderately trained nonelite youth soccer players (age, 16.6 +/- 0.8 years; height, 178.7 +/- 6.2 cm; body mass, 69.8 +/- 6.0 kg; VO2peak, 52.8 +/- 7.4 ml x kg(-1) x min(-1)) while performing the YYIET and an incremental treadmill test. Maximal heart rate (HRmax), respiratory exchange ratio (RER), O2 pulse, VO2peak, and maximal ventilation (VEmax) were measured. Group YYIET VO2peak, HRmax, RER, and O2 pulse were not significantly different from treadmill responses (p > 0.05). VEmax was significantly lower (p < 0.05) during the YYIET compared to the treadmill condition. No significant correlation was found between treadmill VO2peak and YYIET performance (p > 0.05). This study showed that the YYIET elicits peak VO2 and HR responses. However, YYIET performance results were not related to VO2peak measured in laboratory. Furthermore, the individual VO2peak reached during the TM did not reflect the VO2peak obtained during the YYIET, as shown by the large limits of agreement. As a consequence, compared to other shuttle run field tests, YYIET seems to be a weak indicator of aerobic power in youth moderately trained youth soccer player.

  8. Stabilization of oxidovanadium(IV) by organic radicals.

    PubMed

    Kundu, Suman; Maity, Suvendu; Maity, Amarendra Nath; Ke, Shyue-Chu; Ghosh, Prasanta

    2013-04-07

    o-Imino-p-R'-benzosemiquinone anion radical (L(R')(IS)(˙-)) complexes of oxidovanadium(IV) of type [(L(1)(R-))(VO(2+))(L(R')(IS)(˙-))] (R = H, R' = H, 1; R = H, R' = -CMe(3), 2; R = -CMe(3), R' = H, 3 and R = -CMe(3), R' = -CMe(3), 4) incorporating the redox-innocent tridentate NNO-donor L(1)(R-) ligands (L(1)(R)H = 2,4-di-R-6-{(2-(pyridin-2-yl)hydrazono)methyl}phenol) were isolated and substantiated by elemental analyses, IR, mass, NMR and UV-vis spectra including the single crystal X-ray structure determinations. The V-O(phenolato) (cis to the V=O) lengths spanning 1.905(3)-1.9355(15) Å in 1-4 are consistent with the coordination to the [VO](2+) state. The V-O(IS) (trans to the V=O) lengths, 2.1505(17)-2.1869(15) Å, in 1-4 are longer due to the trans influence of the V=O bond. The V-N(IS) lengths, 1.906(3)-1.924(2) Å, in 1-4 are comparatively shorter due to the higher affinity of the paramagnetic [VO](2+) ion towards the L(R')(IS)(˙-) anion radicals. Density functional theory (DFT) calculations using B3LYP, B3PW91 and PBE1PBE functionals on 1 and 2 authenticated that the closed shell singlet (CSS) solutions (dianionic o-amido-p-R'-phenolates (L(R')(AP)(2-)) coordinated to VO(3+), Type I) of 1-4 are unstable with respect to the open shell singlet (OSS) perturbations. Broken symmetry, BS (1,1) M(s) = 0 (L(R')(IS)(˙-) coordinated to the VO(2+) ion, Type III) solutions of 1-4 are stable and reproduce the experimental bond parameters. Frozen glasses EPR spectra of [1-4](+) ions (e.g. g(||) = 1.948, g(⊥) = 1.978, A(||) = 184 (22 G), A(⊥) = 62(15 G) for [2](+)) and unrestricted DFT calculations on [1](+), [2](+), [1](-) and [2](-) ions using doublet spin state elucidated that the reversible anodic waves at [0.15-0.31] V of 1-4 complexes are due to the oxidation of L(R')(IS)(˙-) generating [(L(1)(R-))(VO(2+))(L(R')(IQ))]+ complexes (L(R')(IQ) = o-imino-p-R'-benzoquinone) coordinated to the [VO](2+) ion (Type V) while the irreversible cathodic waves at -[1.08-1.49] V are due to the formation of unstable [(L(1)(R-))(VO(2+))(L(R')(AP)(2-))](-) complexes (Type II). The second anodic waves at [0.76-0.89] V are assigned to a [VO](3+)-[VO](2+) couple affording diamagnetic [(L(1)(R-))(VO(3+))(L(R')(IQ))](2+), [1-4](2+) complexes (Type VI) which are identified by UV-vis spectra, DFT and time dependent (TD) DFT calculations. Spectro-electrochemical measurements and TD DFT calculations on 1 and 2 disclosed that lower energy electronic absorption bands of 1-4 are due to the LMCT and CSS-OSS perturbation which disappear in [1-4](+) ions. [1-4](+) absorb at 600-650 nm due to d-d transitions and MLCT which are absent in VO(3+) complexes, [1-4](2+).

  9. Growth and characterization of ultra thin vanadium oxide films

    NASA Astrophysics Data System (ADS)

    Song, Fangfang

    This dissertation focuses on the growth and characterization of ultra thin VO2 films on technologically relevant Si/SiO2 substrate. The samples were prepared by magnetron sputtering with varying deposition and post annealing conditions. VO2(M1) films prepared under optimal condition with thickness around 42nm shows a continuous micro-structure and a metal insulator transition with resistivity change of two orders of magnitude. The transition temperature is determined to be 345K with a hysteresis width of approximately 8°C. The activation energy of the low temperature semiconducting VO2 monoclinic phase is determined to be 0.16+/-0.03ev. These properties are found to be fairly stable over time under ambient atmosphere. Temperature dependent hall measurements suggest that the decrease of the resistivity with increasing temperature is mainly caused by the increase of the number density of charge carriers, the energy gap of VO2 film in the semiconducting phase is 0.4ev and phonon scattering is the dominant scattering mechanism in the temperature range from 195K to 340K. Analysis based on composite model suggested that the sample has some untransitional phases with a length that is 1/4 of the grain size. Stress measurements using X-ray diffraction indicate that the ultra thin VO2 film has a large tensile stress of 2.0+/-0.2GPa. This value agrees well with that calculated thermal stress assuming the stress is due to differential thermal expansion between VO2 film and substrate. The stress is expected to lead to a shift of the transition temperature in the film, as observed. Using magnetron sputtering, VO2(B) film was able to obtained on Si substrate. The temperature dependent current voltage measurement on VO2(B) film did not show any abrupt change in the electrical resistivity. W - VO2(B) thin film - W metal semiconductor-metal I-V properties were found to be determined by reverse biased Schottky barrier at the W/VO 2(b) interface. And the Schottky height between VO2(B) and W was determined to be about 0.15ev, which indicate the electron affinity of the VO2(B) is about 4.35ev.

  10. Ventilatory and Physiological Responses in Swimmers Below and Above Their Maximal Lactate Steady State.

    PubMed

    Espada, Mario C; Reis, Joana F; Almeida, Tiago F; Bruno, Paula M; Vleck, Veronica E; Alves, Francisco B

    2015-10-01

    The purpose of this study was to understand the ventilatory and physiological responses immediately below and above the maximal lactate steady-state (MLSS) velocity and to determine the relationship of oxygen uptake (VO2) kinetics parameters with performance, in swimmers. Competitive athletes (N = 12) completed in random order and on different days a 400-m all-out test, an incremental step test comprising 5 × 250- and 1 × 200-m stages and 30 minutes at a constant swimming velocity (SV) at 87.5, 90, and 92.5% of the maximal aerobic velocity for MLSS velocity (MLSSv) determination. Two square-wave transitions of 500 m, 2.5% above and below the MLSSv were completed to determine VO2 on-kinetics. End-exercise VO2 at 97.5 and 102.5% of MLSSv represented, respectively, 81 and 97% of VO2max; the latter was not significantly different from maximal VO2 (VO2max). The VO2 at MLSSv (49.3 ± 9.2 ml·kg(-1)·min(-1)) was not significantly different from the second ventilatory threshold (VT2) (51.3 ± 7.6 ml·kg(-1)·min(-1)). The velocity associated with MLSS seems to be accurately estimated by the SV at VT2 (vVT2), and vVO2max also seems to be estimated with accuracy from the central 300-m mean velocity of a 400-m trial, indicators that represent a helpful tool for coaches. The 400-m swimming performance (T400) was correlated with the time constant of the primary phase VO2 kinetics (τp) at 97.5% MLSSv, and T800 was correlated with τp in both 97.5 and 102.5% of MLSSv. The assessment of the VO2 kinetics in swimming can help coaches to build training sets according to a swimmer's individual physiological response.

  11. Variables Measured during Cardiopulmonary Exercise Testing as Predictors of Mortality in Chronic Systolic Heart Failure

    PubMed Central

    Keteyian, Steven J.; Patel, Mahesh; Kraus, William E.; Brawner, Clinton A.; McConnell, Timothy R.; Piña, Ileana L.; Leifer, Eric S.; Fleg, Jerome L.; Blackburn, Gordon; Fonarow, Gregg C.; Chase, Paul J.; Piner, Lucy; Vest, Marianne; O’Connor, Christopher M.; Ehrman, Jonathan K.; Walsh, Mary N.; Ewald, Gregory; Bensimhon, Dan; Russell, Stuart D.

    2015-01-01

    BACKGROUND Data from a cardiopulmonary exercise (CPX) test are used to determine prognosis in patients with chronic heart failure (HF). However, few published studies have simultaneously compared the relative prognostic strength of multiple CPX variables. OBJECTIVES We sought to describe the strength of the association among variables measured during a CPX test and all-cause mortality in patients with HF with reduced ejection fraction (HFrEF), including the influence of sex and patient effort, as measured by respiratory exchange ratio (RER). METHODS Among patients (n = 2,100, 29% women) enrolled in the HF-ACTION (HF-A Controlled Trial Investigating Outcomes of exercise traiNing) trial, 10 CPX test variables measured at baseline (e.g., peak oxygen uptake [VO2], exercise duration, percent predicted peak VO2 [%ppVO2], ventilatory efficiency) were examined. RESULTS Over a median follow-up of 32 months, there were 357 deaths. All CPX variables, except RER, were related to all-cause mortality (all p < 0.0001). Both %ppVO2 and exercise duration were equally able to predict (Wald χ2: ~141) and discriminate (c-index: 0.69) mortality. Peak VO2 (mL·kg−1·min−1) was the strongest predictor of mortality among men (Wald χ2: 129) and exercise duration among women (Wald χ2: 41). Multivariable analyses showed that %ppVO2, exercise duration, and peak VO2 (mL·kg−1·min−1) were similarly able to predict and discriminate mortality. In men, a 10% 1-year mortality rate corresponded to a peak VO2 of 10.9 mL·kg−1·min−1 versus 5.3 mlkg−1/min−1 in women. CONCLUSIONS Peak VO2, exercise duration, and % ppVO2 carried the strongest ability to predict and discriminate the likelihood of death in patients with HFrEF. The prognosis associated with a given peak V2 differed by sex. PMID:26892413

  12. Structure and enhanced thermochromic performance of low-temperature fabricated VO2/V2O3 thin film

    NASA Astrophysics Data System (ADS)

    Sun, Guangyao; Cao, Xun; Gao, Xiang; Long, Shiwei; Liang, Mengshi; Jin, Ping

    2016-10-01

    For VO2-based smart window manufacture, it is a long-standing demand for high-quality thin films deposited at low temperature. Here, the thermochromic films of VO2 were deposited by a magnetron sputtering method at a fairly low temperature of 250 °C without subsequent annealing by embedding a V2O3 interlayer. V2O3 acts as a seed layer to lower the depositing temperature and buffer layer to epitaxial grow VO2 film. The VO2/V2O3 films display high solar modulating ability and narrow hysteresis loop. Our data can serve as a promising point for industrial production with high degree of crystallinity at a low temperature.

  13. Hybrid Ag 2VO 2PO 4/CF x as a High Capacity and Energy Cathode for Primary Batteries

    DOE PAGES

    Li, Yue Ru; Bruck, Andrea M.; Brady, Alexander B.; ...

    2017-08-18

    In this report, we describe the electrochemistry of hybrid dual silver vanadium phosphorus oxide/carbon fluoride (Ag 2VO 2PO 4/CF x) cathodes with various weight ratios. Through modification of the Ag 2VO 2PO 4/CF x ratio, we can control the gravimetric and volumetric capacity, as well as mitigate the voltage drop during high current pulses. The increase in impedance caused by irreversible LiF formation in CFx was reduced by the silver reduction-displacement during electrochemical discharge of the Ag 2VO 2PO 4. Moreover, the addition of graphite was shown to reduce initial voltage delay. When Ag 2VO 2PO 4 dominates the electrodemore » mass (i.e. 75/25 Ag 2VO 2PO 4/CF x) in the hybrid cathode, pulse testing shows less voltage drop and delay, but at the expense of capacity and energy density. As the amount of CFx in the composite increases (i.e. Ag 2VO 2PO 4/CF x ratio of to 50/50 or 25/75), charge capacity and energy density increases, but at the expense of larger voltage drops and delays early in the discharge process. Thus, controlling the Ag 2VO 2PO 4/CF x ratio can be used to tune the electrochemical properties of the dual cathode, allowing for optimization of capacity and power depending on the application.« less

  14. Hybrid Ag 2VO 2PO 4/CF x as a High Capacity and Energy Cathode for Primary Batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Yue Ru; Bruck, Andrea M.; Brady, Alexander B.

    In this report, we describe the electrochemistry of hybrid dual silver vanadium phosphorus oxide/carbon fluoride (Ag 2VO 2PO 4/CF x) cathodes with various weight ratios. Through modification of the Ag 2VO 2PO 4/CF x ratio, we can control the gravimetric and volumetric capacity, as well as mitigate the voltage drop during high current pulses. The increase in impedance caused by irreversible LiF formation in CFx was reduced by the silver reduction-displacement during electrochemical discharge of the Ag 2VO 2PO 4. Moreover, the addition of graphite was shown to reduce initial voltage delay. When Ag 2VO 2PO 4 dominates the electrodemore » mass (i.e. 75/25 Ag 2VO 2PO 4/CF x) in the hybrid cathode, pulse testing shows less voltage drop and delay, but at the expense of capacity and energy density. As the amount of CFx in the composite increases (i.e. Ag 2VO 2PO 4/CF x ratio of to 50/50 or 25/75), charge capacity and energy density increases, but at the expense of larger voltage drops and delays early in the discharge process. Thus, controlling the Ag 2VO 2PO 4/CF x ratio can be used to tune the electrochemical properties of the dual cathode, allowing for optimization of capacity and power depending on the application.« less

  15. Metabolic and cardiac responses to robotic-assisted locomotion in motor-complete tetraplegia: a case report.

    PubMed

    Nash, Mark S; Jacobs, Patrick L; Johnson, Brad M; Field-Fote', Edelle

    2004-01-01

    To examine acute metabolic responses to treadmill locomotion in a participant with motor-complete tetraplegia. The participant--a woman with a chronic ASIA B C3-C4 spinal cord injury--walked on a treadmill with 40% body weight support (BWS) and robotic assistance. Oxygen consumption (VO2), minute ventilation (VE), and heart rate (HR) were measured during seated resting, supported standing, and 40 minutes of walking with stepping assistance from a Lokomat-driven gait orthosis. A resting VO2 equal to 50 milliliters per minute was predictably low, and did not change after the participant assumed an upright posture. Both VO2 and VE increased immediately upon onset of locomotion, suggesting a neurogenic rather than a humoral regulatory response to movement. VO2 averaged 2.4 metabolic units (METS) during locomotion at an average expenditure of 2.98 kilocalories per minute. HR was unaltered by standing, but during locomotion averaged 1 7 beats higher than during resting. Increases in VE but not VO2 upon standing, and decreases in VO2 but not VE immediately after walking, rule out changes in VE alone as the source for increased VO2 during walking. The data collected on this single participant show that treadmill locomotion with BWS and robotic assistance elicits a metabolic response to treadmill gaiting characterized by increased VO2, VE, HR, and caloric expenditure.

  16. A cost-effective process to prepare VO{sub 2} (M) powder and films with superior thermochromic properties

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xiao, Xiudi; Zhang, Hua; Chai, Guanqi

    2014-03-01

    Graphical abstract: Combining codeposition and short time post annealing, VO{sub 2} (M) with high quality and excellent phase transition performance is obtained. After mixing the VO{sub 2} powder with acrylic resin, the composite films deposited on glass show superior visible transmission and solar modulation, which can be used as an excellent candidate of low cost smart window in energy saving field. - Highlights: • The VO{sub 2} powder obtained by short time thermolysis method is high purity and crystallinity with superior phase transition performance. • The maximum decreasing efficiency of phase transition temperature is about −30 K/at% with w =more » 0.4 at%. • After mixing VO{sub 2} powder with acrylic resin, the maximal visible transmission of the composite films is 48% and the transmission modulation at 2000 nm is 37.3% with phase transition temperature of 66.2 °C. • Though the phase transition performance is weakened by tungsten doping, the film prepared by 1.3 at% tungsten doped VO{sub 2} still show superior transmission modulation about 26.4%, which means that it is a potential candidate as smart windows. - Abstract: VO{sub 2} powder with superior phase transition performance was prepared by convenient thermolysis method. The results illustrated that VO{sub 2} powder show high purity and crystallinity. VO{sub 2} particles are transformed from cluster to quasi-sphere with the increase of annealing temperature. The DSC analysis proves that VO{sub 2} show superior phase transition performance around 68 °C. The phase transition temperature can be reduced to 33.5 °C by 1.8 at% tungsten doping. The maximum decreasing efficiency of phase transition temperature is about −30 K/at% with w = 0.4 at%. After mixing VO{sub 2} powder with acrylic resin, the maximal visible transmission of the composite thin films on glass is 48% and the transmission modulation at 2000 nm is 37.3% with phase transition temperature of 66.2 °C. Though the phase transition performance is weakened by tungsten doping, the film prepared by 1.3 at% tungsten doped VO{sub 2} still show superior transmission modulation about 26.4% at 2000 nm, which means that it is a potential candidate as smart windows.« less

  17. Energy expenditure during bicycling.

    PubMed

    McCole, S D; Claney, K; Conte, J C; Anderson, R; Hagberg, J M

    1990-02-01

    This study was designed to measure the O2 uptake (VO2) of cyclists while they rode outdoors at speeds from 32 to 40 km/h. Regression analyses of data from 92 trials using the same wheels, tires, and tire pressure with the cyclists riding in their preferred gear and in an aerodynamic position indicated the best equation (r = 0.84) to estimate VO2 in liters per minute VO2 = -4.50 + 0.17 rider speed + 0.052 wind speed + 0.022 rider weight where rider and wind speed are expressed in kilometers per hour and rider weight in kilograms. Following another rider closely, i.e., drafting, at 32 km/h reduced VO2 by 18 +/- 11%; the benefit of drafting a single rider at 37 and 40 km/h was greater (27 +/- 8%) than that at 32 km/h. Drafting one, two, or four riders in a line at 40 km/h resulted in the same reduction in VO2 (27 +/- 7%). Riding at 40 km/h at the back of a group of eight riders reduced VO2 by significantly more (39 +/- 6%) than drafting one, two, or four riders in a line; drafting a vehicle at 40 km/h resulted in the greatest decrease in VO2 (62 +/- 6%). VO2 was also 7 +/- 4% lower when the cyclists were riding an aerodynamic bicycle. An aerodynamic set of wheels with a reduced number of spokes and one set of disk wheels were the only wheels to reduce VO2 significantly while the cyclists were riding a conventional racing bicycle at 40 km/h.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Fundamental Studies on Confinement Effects in Ionic Conduction and Inversion Layers in 2-D Single Crystal Free Standing Oxide Membranes

    DTIC Science & Technology

    2014-02-14

    properties of VO2 films and membranes and compare the results with annealing VO2 films and membranes in hydrogen to provide insight into the doping...2-dimensional free standing membrane with correlated oxides may also lead to new insights into mesoscopic electronic phenomena. Vanadium oxide ( VO2 ...well as for potential applications in switching devices. While studies have been conducted on thin films, hybrid layers of VO2 supported on other

  19. Measurement of systemic oxygen consumption in patients during extracorporeal membrane oxygenation--description of a new method and the first clinical observations.

    PubMed

    Cheypesh, A; Yu, X; Li, J

    2014-01-01

    Extracorporeal membrane oxygenation (ECMO) provides temporary life-saving support for patients with severe cardiac failure, but is associated with significant morbidity and mortality. While ECMO enables oxygen delivery (DO2), little is known about oxygen consumption (VO2), largely due to technical difficulties. We aimed to introduce the adaptation of respiratory mass spectrometry to measure VO2 in patients during ECMO and to use this unique model to determine the pathological dependency of VO2 on DO2 in humans. Respiratory mass spectrometry remains the 'state-of-the-art' method, allowing the highly sensitive and rapid measurement of VO2 in critically ill patients. The principle and design of the respiratory mass spectrometer are described, together with the setting up of this machine with the ECMO oxygenator and the native lungs of the patients. In two patients with severe dilated cardiomyopathy and little cardiac contraction, the decrease in pump flow and, hence, DO2 by 20% was associated with a decrease in VO2 by 5% and 8%, respectively, whereas the increase in pump flow was not associated with any significant change in VO2. The direct measurement of VO2 by respiratory mass spectrometry in ECMO patients provides a unique technique for clinical research on the metabolism and VO2-DO2 relationship in this special group of critically ill patients. Our pilot study is the first to demonstrate a pathological dependency of VO2 on DO2 in humans. Further studies are warranted with this technique to examine the changes and the factors affecting systemic oxygen transport in patients during ECMO.

  20. Mg-doped VO2 nanoparticles: hydrothermal synthesis, enhanced visible transmittance and decreased metal-insulator transition temperature.

    PubMed

    Zhou, Jiadong; Gao, Yanfeng; Liu, Xinling; Chen, Zhang; Dai, Lei; Cao, Chuanxiang; Luo, Hongjie; Kanahira, Minoru; Sun, Chao; Yan, Liuming

    2013-05-28

    This paper reports the successful preparation of Mg-doped VO2 nanoparticles via hydrothermal synthesis. The metal-insulator transition temperature (T(c)) decreased by approximately 2 K per at% Mg. The Tc decreased to 54 °C with 7.0 at% dopant. The composite foils made from Mg-doped VO2 particles displayed excellent visible transmittance (up to 54.2%) and solar modulation ability (up to 10.6%). In addition, the absorption edge blue-shifted from 490 nm to 440 nm at a Mg content of 3.8 at%, representing a widened optical band gap from 2.0 eV for pure VO2 to 2.4 eV at 3.8 at% doping. As a result, the colour of the Mg-doped films was modified to increase their brightness and lighten the yellow colour over that of the undoped-VO2 film. A first principle calculation was conducted to understand how dopants affect the optical, Mott phase transition and structural properties of VO2.

  1. Two-Dimensional SiO2/VO2 Photonic Crystals with Statically Visible and Dynamically Infrared Modulated for Smart Window Deployment.

    PubMed

    Ke, Yujie; Balin, Igal; Wang, Ning; Lu, Qi; Tok, Alfred Iing Yoong; White, Timothy J; Magdassi, Shlomo; Abdulhalim, Ibrahim; Long, Yi

    2016-12-07

    Two-dimensional (2D) photonic structures, widely used for generating photonic band gaps (PBG) in a variety of materials, are for the first time integrated with the temperature-dependent phase change of vanadium dioxide (VO 2 ). VO 2 possesses thermochromic properties, whose potential remains unrealized due to an undesirable yellow-brown color. Here, a SiO 2 /VO 2 core/shell 2D photonic crystal is demonstrated to exhibit static visible light tunability and dynamic near-infrared (NIR) modulation. Three-dimensional (3D) finite difference time domain (FDTD) simulations predict that the transmittance can be tuned across the visible spectrum, while maintaining good solar regulation efficiency (ΔT sol = 11.0%) and high solar transmittance (T lum = 49.6%). Experiments show that the color changes of VO 2 films are accompanied by NIR modulation. This work presents a novel way to manipulate VO 2 photonic structures to modulate light transmission as a function of wavelength at different temperatures.

  2. Aerobic oxidations catalyzed by chromium corroles.

    PubMed

    Mahammed, Atif; Gray, Harry B; Meier-Callahan, Alexandre E; Gross, Zeev

    2003-02-05

    Oxochromium(V) complexes of 5,10,15-tris(pentafluorophenyl)corrole and brominated derivatives oxygenate substrates (triphenylphosphine and norbornene) with concomitant production of chromium(III). Regeneration of CrVO by reaction of dioxygen with CrIII completes an aerobic catalytic cycle, with very large solvent effects; in acetonitrile, rapid initial turnovers observed initially are shut down by formation of CrIVO, while in toluene, THF, and methanol, relatively slow reactions are further inhibited by product formation.

  3. Cardiopulmonary fitness in a sample of Malaysian population.

    PubMed

    Singh, R; Singh, H J; Sirisinghe, R G

    1989-01-01

    Lung capacity and maximum oxygen uptake (VO2max) were measured directly in 167 healthy males, from all the main races in Malaysia. Their ages ranged from 13 to 59 years. They were divided into five age groups (A to E), ranging from the second to the sixth decade. Lung capacities were determined using a dry spirometer and VO2max was taken as the maximum rate of oxygen consumption during exhaustive exercise on a cycle ergometer. Mean forced vital capacity (FVC) was 3.3 +/- 0.5 l and it correlated negatively with age. Mean VO2max was 3.2 +/- 0.2 l.min-1 (56.8 +/- 3.5 ml.kg-1.min-1) in Group A (13-19 years) compared to 1.7 +/- 0.2 l.min-1 (28.9 +/- 2.9 ml.kg-1.min-1) in Group E (50-59 years). Regression analysis revealed an age-related decline in VO2max of 0.77 ml.kg-1.min-1.year-1. Multiple regression of the data gave the following equations for the prediction of an individual's VO2max: VO2max (l.min-1) = 1.99 + 0.035 (weight)-0.04 (age), VO2max (ml.kg-1.min-1) = 67.7-0.77 (age), where age is in years, weight in kg. In terms of VO2max as an index of cardiopulmonary performance. Malaysians have a relatively lower capacity when related to the Swedish norms or even to those of some Chilean workers. Malaysians were, however, within the average norms of the American Heart Association's recommendations. Age-related decline in VO2max was also somewhat higher in the Malaysians.

  4. A Real-time Spectrum Handoff Algorithm for VoIP based Cognitive Radio Networks: Design and Performance Analysis

    NASA Astrophysics Data System (ADS)

    Chakraborty, Tamal; Saha Misra, Iti

    2016-03-01

    Secondary Users (SUs) in a Cognitive Radio Network (CRN) face unpredictable interruptions in transmission due to the random arrival of Primary Users (PUs), leading to spectrum handoff or dropping instances. An efficient spectrum handoff algorithm, thus, becomes one of the indispensable components in CRN, especially for real-time communication like Voice over IP (VoIP). In this regard, this paper investigates the effects of spectrum handoff on the Quality of Service (QoS) for VoIP traffic in CRN, and proposes a real-time spectrum handoff algorithm in two phases. The first phase (VAST-VoIP based Adaptive Sensing and Transmission) adaptively varies the channel sensing and transmission durations to perform intelligent dropping decisions. The second phase (ProReact-Proactive and Reactive Handoff) deploys efficient channel selection mechanisms during spectrum handoff for resuming communication. Extensive performance analysis in analytical and simulation models confirms a decrease in spectrum handoff delay for VoIP SUs by more than 40% and 60%, compared to existing proactive and reactive algorithms, respectively and ensures a minimum 10% reduction in call-dropping probability with respect to the previous works in this domain. The effective SU transmission duration is also maximized under the proposed algorithm, thereby making it suitable for successful VoIP communication.

  5. o-Iminobenzosemiquinonate and o-imino-p-methylbenzosemiquinonate anion radicals coupled VO2+ stabilization.

    PubMed

    Roy, Amit Saha; Saha, Pinaki; Adhikary, Nirmal Das; Ghosh, Prasanta

    2011-03-21

    The diamagnetic VO(2+)-iminobenzosemiquinonate anion radical (L(R)(IS)(•-), R = H, Me) complexes, (L(-))(VO(2+))(L(R)(IS)(•-)): (L(1)(-))(VO(2+))(L(H)(IS)(•-))•3/2MeOH (1•3/2MeOH), (L(2)(-))(VO(2+))(L(H)(IS)(•-)) (2), and (L(2)(-))(VO(2+))(L(Me)(IS)(•-))•1/2 L(Me)(AP) (3•1/2 L(Me)(AP)), incorporating tridentate monoanionic NNO-donor ligands {L = L(1)(-) or L(2)(-), L(1)H = (2-[(phenylpyridin-2-yl-methylene)amino]phenol; L(2)H = 1-(2-pyridylazo)-2-naphthol; L(H)(IS)(•-) = o-iminobenzosemiquinonate anion radical; L(Me)(IS)(•-) = o-imino-p-methylbenzosemiquinonate anion radical; and L(Me)(AP) = o-amino-p-methylphenol} have been isolated and characterized by elemental analyses, IR, mass, NMR, and UV-vis spectra, including the single-crystal X-ray structure determinations of 1•3/2MeOH and 3•1/2 L(Me)(AP). Complexes 1•3/2MeOH, 2, and 3•1/2 L(Me)(AP) absorb strongly in the visible region because of intraligand (IL) and ligand-to-metal charge transfers (LMCT). 1•3/2MeOH is luminescent (λ(ext), 333 nm; λ(em), 522, 553 nm) in frozen dichloromethane-toluene glass at 77 K due to π(diimine→)π(diimine)* transition. The V-O(phenolato) (cis to the V═O) lengths, 1.940(2) and 1.984(2) Å, respectively, in 1•3/2MeOH and 3•1/2 L(Me)(AP) are consistent with the VO(2+) description. The V-O(iminosemiquinonate) (trans to the V═O) lengths, 2.1324(19) in 1•3/2MeOH and 2.083(2) Å in 3•1/2 L(Me)(AP), are expectedly ∼0.20 Å longer due to the trans influence of the V═O bond. Because of the stronger affinity of the paramagnetic VO(2+) ion to the L(H)(IS)(•-) or L(Me)(IS)(•-), the V-N(iminosemiquinonate) lengths, 1.908(2) and 1.921(2) Å, respectively, in 1•3/2MeOH and 3•1/2 L(Me)(AP), are unexpectedly shorter. Density functional theory (DFT) calculations using B3LYP, B3PW91, and PBE1PBE functionals on 1 and 2 have established that the closed shell singlet (CSS) solutions (VO(3+)-amidophenolato (L(R)(AP)(2-)) coordination) of these complexes are unstable with respect to triplet perturbations. But BS (1,1) M(s) = 0 (VO(2+)-iminobenzosemiquinonate anion radical (L(R)(IS)(•-)) coordination) solutions of these species are stable and reproduce the experimental bond parameters well. Spin density distributions of one electron oxidized cations are consistent with the [(L(-))(VO(2+))(L(R)(IQ))](+) descriptions [VO(2+)-o-iminobenzoquinone (L(R)(IQ)) coordination], and one electron reduced anions are consistent with the [(L(•2-))(VO(3+))(L(R)(AP)(2-))](-) descriptions [VO(3+)-amidophenolato (L(R)(AP)(2-)) coordination], incorporating the diimine anion radical (L(1)(•2-)) or azo anion radical (L(2)(3-)). Although, cations and anions are not isolable, but electro-and spectro-electrochemical experiments have shown that 3(+) and 3(-) ions are more stable than 1(+), 2(+) and 1(-), 2(-) ions. In all cases, the reductions occur with simultaneous two electron transfer, may be due to formation of coupled diimine/azo anion radical-VO(2+) species as in [(L(•2-))(VO(2+))(L(R)(AP)(2-))](2-).

  6. Infrared spectra of the ammonium ion in ammonium hexavanadate (NH 4) 2V 6O 16

    NASA Astrophysics Data System (ADS)

    de Waal, D.; Heyns, A. M.; Range, K.-J.; Eglmeier, C.

    The infrared bands of the NH +4 and ND +4 groups in (NH 4) 2V 6O 16 and its deuterated analogue can be assigned with a fair amount of certainty at 90 K under the space group P2 1/ m( C22 h). The ND stretching modes of isotopically dilute NH 3D + ions in the crystal are in agreement with the predicted splitting into Cs, Cs and C1(2) components. The frequencies, shapes and temperature dependence of these modes suggest that both normal and bifurcated hydrogen bonds are formed. The latter closely resembles corresponding bonds in NH 4VO 3, but the normal hydrogen bonds are not as strong as the similar bonds in NH 4VO 3. This can be expected as NH +4 ions are dynamic in character in (NH 4) 2V 6O 16 and remain so down to temperatures of 90 K.

  7. Physical activity enhances metabolic fitness independently of cardiorespiratory fitness in marathon runners.

    PubMed

    Laye, M J; Nielsen, M B; Hansen, L S; Knudsen, T; Pedersen, B K

    2015-01-01

    High levels of cardiovascular fitness (CRF) and physical activity (PA) are associated with decreased mortality and risk to develop metabolic diseases. The independent contributions of CRF and PA to metabolic disease risk factors are unknown. We tested the hypothesis that runners who run consistently >50 km/wk and/or >2 marathons/yr for the last 5 years have superior metabolic fitness compared to matched sedentary subjects (CRF, age, gender, and BMI). Case-control recruitment of 31 pairs of runner-sedentary subjects identified 10 matched pairs with similar VO2max (mL/min/kg) (similar-VO2max). The similar-VO2max group was compared with a group of age, gender, and BMI matched pairs who had the largest difference in VO2max (different-VO2max). Primary outcomes that defined metabolic fitness including insulin response to an oral glucose tolerance test, fasting lipids, and fasting insulin were superior in runners versus sedentary controls despite similar VO2max. Furthermore, performance (velocity at VO2max, running economy), improved exercise metabolism (lactate threshold), and skeletal muscle levels of mitochondrial proteins were superior in runners versus sedentary controls with similar VO2max. In conclusion subjects with a high amount of PA have more positive metabolic health parameters independent of CRF. PA is thus a good marker against metabolic diseases.

  8. Physical Activity Enhances Metabolic Fitness Independently of Cardiorespiratory Fitness in Marathon Runners

    PubMed Central

    Laye, M. J.; Nielsen, M. B.; Hansen, L. S.; Knudsen, T.; Pedersen, B. K.

    2015-01-01

    High levels of cardiovascular fitness (CRF) and physical activity (PA) are associated with decreased mortality and risk to develop metabolic diseases. The independent contributions of CRF and PA to metabolic disease risk factors are unknown. We tested the hypothesis that runners who run consistently >50 km/wk and/or >2 marathons/yr for the last 5 years have superior metabolic fitness compared to matched sedentary subjects (CRF, age, gender, and BMI). Case-control recruitment of 31 pairs of runner-sedentary subjects identified 10 matched pairs with similar VO2max (mL/min/kg) (similar-VO2max). The similar-VO2max group was compared with a group of age, gender, and BMI matched pairs who had the largest difference in VO2max (different-VO2max). Primary outcomes that defined metabolic fitness including insulin response to an oral glucose tolerance test, fasting lipids, and fasting insulin were superior in runners versus sedentary controls despite similar VO2max. Furthermore, performance (velocity at VO2max, running economy), improved exercise metabolism (lactate threshold), and skeletal muscle levels of mitochondrial proteins were superior in runners versus sedentary controls with similar VO2max. In conclusion subjects with a high amount of PA have more positive metabolic health parameters independent of CRF. PA is thus a good marker against metabolic diseases. PMID:25821340

  9. Systemic oxygen transport derived by using continuous measured oxygen consumption after the Norwood procedure-an interim review.

    PubMed

    Li, Jia

    2012-07-01

    The balance between systemic O(2)consumption (VO(2)) and O(2)delivery (DO(2)) is impaired in children after cardiopulmonary bypass surgery, with decreased DO(2)and increased VO(2). The major goal, and the major challenge, of postoperative management has been to match DO(2)to VO(2)in order to sustain cellular metabolism, particularly in neonates after the Norwood procedure. While much effort has been put into augmenting cardiac output and DO(2), VO(2)remains largely ignored. Respiratory mass spectrometry allows the precise and continuous measurement of VO(2). Measured VO(2), using the direct Fick principle, allows for the calculation of each element of systemic O(2)transport in the complex Norwood circulation. The actual measurements of O(2)transport have allowed us, in the past five years or so, to extensively investigate the Norwood physiology in terms of the VO(2)-DO(2)relationship and the factors affecting it in clinical treatments. Therefore, the first objective of this article is to introduce the technique of respiratory mass spectrometry and its adaption to measure VO(2)across paediatric ventilators with continuous flow. The second objective is to give an interim review of the main findings in our studies on systemic O(2)transport in 17 neonates in the first 72 h after the Norwood procedure. These findings include the profiles of systemic O(2)transport, the important contribution of VO(2)to the impaired balance of O(2)transport and the complex effects of some routine clinical treatments on the VO(2)-DO(2)relationship (including catecholamines, PaCO(2), Mg(2+)and hyperglycaemia, as well as patient-specific anatomical variations). The influence of systemic O(2)transport on cerebral oxygenation is also introduced. This information may help us to refine postoperative management in neonates after the Norwood procedure. Our initial studies mark the end of the beginning, but much is yet explored. Ultimately, the resultant improved systemic and regional O(2)transport in the early postoperative period may have an important impact on long-term outcomes, thereby improving the quality of life for these vulnerable children.

  10. Left atrial mechanics strongly predict functional capacity assessed by cardiopulmonary exercise testing in subjects without structural heart disease.

    PubMed

    Leite, Luís; Mendes, Sofia Lázaro; Baptista, Rui; Teixeira, Rogério; Oliveira-Santos, Manuel; Ribeiro, Nelson; Coutinho, Rosa; Monteiro, Victor; Martins, Rui; Castro, Graça; Ferreira, Maria João; Pego, Mariano

    2017-05-01

    Left atrium function is essential for cardiovascular performance and is evaluable by two-dimensional speckle-tracking echocardiography (2D-STE). Our aim was to determine how echocardiographic parameters interrelate with exercise capacity and ventilatory efficiency in subjects with no structural heart disease. Asymptomatic volunteers, in sinus rhythm and with normal biventricular size and function, were recruited from a community-based population. Individuals with moderate-to-severe valvular disease, pulmonary hypertension, and history of cardiac disease were excluded. We performed a transthoracic echocardiogram and assessed left atrial (LA) and left ventricular (LV) mechanics via 2D-STE. Cardiopulmonary exercise testing by treadmill took place immediately thereafter. Peak oxygen uptake (VO 2 ) served as measure of functional capacity and ventilation/carbon dioxide output (VE/VCO 2 ) slope as surrogate of ventilation/perfusion mismatch. 20 subjects were included (age 51 ± 14 years, male gender 65%). Peak VO 2 strongly correlated with age (r = -0.83; P < 0.01), with E/e' ratio (r = -0.72; P < 0.01), and with LA reservoir- and conduit-phase mechanics, particularly with LA conduit strain rate (SR) (r = -0.82; P < 0.01), but showed no correlation with LA volume index or LV mechanics. A similar pattern of associations was identified for VE/VCO 2 slope. In multivariate analysis, LA conduit SR (β = -0.69; P = 0.02) emerged as sole independent correlate of peak VO 2 , adjusted for age and for E/e' ratio (adjusted r 2  = 0.76; P < 0.01). Conduit and reservoir components of LA mechanics displayed strong associations with peak VO 2 and VE/VCO 2 slope. LA conduit-phase SR seems best suited as echocardiographic marker of functional capacity in subjects with no structural heart disease.

  11. Effect of wearing clothes on oxygen uptake and ratings of perceived exertion while swimming.

    PubMed

    Choi, S W; Kurokawa, T; Ebisu, Y; Kikkawa, K; Shiokawa, M; Yamasaki, M

    2000-07-01

    For a comparative study between swimming in swimwear (control-sw) and swimming in clothes (clothes-sw), oxygen uptake (VO2) and ratings of perceived exertion (RPE) were measured. The subjects were six male members of a university swimming team. Three swimming strokes--the breaststroke, the front crawl stroke and the elementary backstroke--were applied. With regards to clothes-sw, swimmers wore T-shirts, sportswear (shirt and pants) over swimwear and running shoes. In both cases of control-sw and clothes-sw, the VO2 was increased exponentially with increased swimming speed. The VO2 of the subjects during the clothed tests did not exceed 1.4 times of that in the case of control-sw at swimming speeds below 0.3 m/s. As swimming speeds increased, VO2 difference in both cases increased. Consequently, VO2 in the clothed tests was equal to 1.5-1.6 times and 1.5-1.8 times of that in the swimwear tests at speeds of 0.5 and 0.7 m/s, respectively. At speeds below 0.6 m/s in clothes-sw, the breaststroke showed lower VO2 than the front crawl stroke, and the elementary backstroke showed higher VO2 than the other two swimming strokes. RPE increased linearly with %peak VO2. In addition, any RPE differences among the three swimming strokes were not shown in the control-sw tests. At an exercise intensity above 60 %peak VO2, clothed swimmers showed slightly higher RPE in the front crawl stroke compared to that in the two other swimming strokes.

  12. Atomic Layer Deposition of Vanadium Dioxide and a Temperature-dependent Optical Model.

    PubMed

    Currie, Marc; Mastro, Michael A; Wheeler, Virginia D

    2018-05-23

    Vanadium dioxide is a material that has a reversible metal-insulator phase change near 68 °C. To grow VO2 on a wide variety of substrates, with wafer-scale uniformity and angstrom level control of thickness, the method of atomic-layer deposition was chosen. This ALD process enables high-quality, low-temperature (≤150 °C) growth of ultrathin films (100-1000 Å) of VO2. For this demonstration, the VO2 films were grown on sapphire substrates. This low temperature growth technique produces mostly amorphous VO2 films. A subsequent anneal in an ultra-high vacuum chamber with a pressure of 7x10 -4 Pa of ultra-high purity (99.999%) oxygen produced oriented, polycrystalline VO2 films. The crystallinity, phase, and strain of the VO2 were determined by Raman spectroscopy and X-ray diffraction, while the stoichiometry and impurity levels were determined by X-ray photoelectron spectroscopy, and finally the morphology was determined by atomic force microscopy. These data demonstrate the high-quality of the films grown by this technique. A model was created to fit to the data for VO2 in its metallic and insulating phases in the near infrared spectral region. The permittivity and refractive index of the ALD VO2 agreed well with the other fabrication methods in its insulating phase, but showed a difference in its metallic state. Finally, the analysis of the films' optical properties enabled the creation of a wavelength- and temperature-dependent model of the complex optical refractive index for developing VO2 as a tunable refractive index material.

  13. Human mitochondrial haplogroup H: the highest VO2max consumer--is it a paradox?

    PubMed

    Martínez-Redondo, Diana; Marcuello, Ana; Casajús, José A; Ara, Ignacio; Dahmani, Yahya; Montoya, Julio; Ruiz-Pesini, Eduardo; López-Pérez, Manuel J; Díez-Sánchez, Carmen

    2010-03-01

    Mitochondrial background has been demonstrated to influence maximal oxygen uptake (VO(2max), in mLkg(-1)min(-1)), but this genetic influence can be compensated for by regular exercise. A positive correlation among electron transport chain (ETC) coupling, ATP and reactive oxygen species (ROS) production has been established, and mitochondrial variants have been reported to show differences in their ETC performance. In this study, we examined in detail the VO(2max) differences found among mitochondrial haplogroups. We recruited 81 healthy male Spanish Caucasian individuals and determined their mitochondrial haplogroup. Their VO(2max) was determined using incremental cycling exercise (ICE). VO(2max) was lower in J than in non-J haplogroup individuals (P=0.04). The H haplogroup was responsible for this difference (VO(2max); J vs. H; P=0.008) and this group also had significantly higher mitochondrial oxidative damage (mtOD) than the J haplogroup (P=0.04). In agreement with these results, VO(2max) and mtOD were positively correlated (P=0.01). Given that ROS production is the major contributor to mtOD and consumes four times more oxygen per electron than the ETC, our results strongly suggest that ROS production is responsible for the higher VO(2max) found in the H variant. These findings not only contribute to a better understanding of the mechanisms underneath VO(2max), but also help to explain some reported associations between mitochondrial haplogroups and mtOD with longevity, sperm motility, premature aging and susceptibility to different pathologies.

  14. Application of laser therapy in the treatment of brain ischemia

    NASA Astrophysics Data System (ADS)

    Zalesskaya, G. A.; Nechipurenko, N. I.; Musienko, J. I.; Kuchinsky, A. V.

    2007-06-01

    Intravenous laser irradiation of blood (ILIB) by helium-neon laser (HNL) with λ=632.8 nm, 2.5-4.5 mW at the light guide outlet was employed to investigate ILIB influence on blood oxygen transport (BOT), hydro-ion balance for normal rabbits and after modeling of local ischemia of brain (LIB). Marked improvement of disturbances typical for ischemia was revealed for both hydro-ion balance characteristics and BOT parameters such as oxygen tension (p vO II), oxygen hemoglobin saturation (s vO II), p vO II of blood under its 50% saturation by O II (p50) and tendency was found to their normalization. To identify the molecular photoacceptors and the mechanisms of primary photoreactions the spectral data were used both in visible and infrared regions. On the basis of spectral analysis hemoglobin was discussed as a possible photoacceptor when blood is irradiated with HNL radiation. Variations in the redox properties of respiratory chain components were considered as primary mechanisms of light action on photoacceptor molecules that initiated a cascade of secondary reactions controlling cellular homeostasis parameters.

  15. Effects of dominant somatotype on aerobic capacity trainability.

    PubMed

    Chaouachi, M; Chaouachi, A; Chamari, K; Chtara, M; Feki, Y; Amri, M; Trudeau, F

    2005-12-01

    This study examined the association between dominant somatotype and the effect on aerobic capacity variables of individualised aerobic interval training. Forty one white North African subjects (age 21.4+/-1.3 years; Vo2max = 52.8+/-5.7 ml kg(-1) min(-1)) performed three exercise tests 1 week apart (i) an incremental test on a cycle ergometer to determine Vo2max and Vo2 at the second ventilatory threshold (VT2); (ii) a VAM-EVAL track test to determine maximal aerobic speed (vVo2max); and (iii) an exhaustive constant velocity test to determine time limit performed at 100% vVo2max (tlim100). Subjects were divided into four somatometric groups: endomorphs-mesomorphs (Endo-meso; n = 9), mesomorphs (Meso; n = 11), mesomorphs-ectomorphs (Meso-ecto; n = 12), and ectomorphs (Ecto; n = 9). Subjects followed a 12 week training program (two sessions/week). Each endurance training session consisted of the maximal number of successive fractions for each subject. Each fraction consisted of one period of exercise at 100% of vVo2max and one of active recovery at 60% of vVo2max. The duration of each period was equal to half the individual tlim100 duration (153.6+/-39.7 s). After the training program, all subjects were re-evaluated for comparison with pre-test results. Pre- and post-training data were grouped by dominant somatotype. Two way ANOVA revealed significant somatotype-aerobic training interaction effects (p<0.001) for improvements in vVo2max, Vo2max expressed classically and according to allometric scaling, and Vo2 at VT2. There were significant differences among groups post-training: the Meso-ecto and the Meso groups showed the greatest improvements in aerobic capacity. The significant somatotype-aerobic training interaction suggests different trainability with intermittent and individualised aerobic training according to somatotype.

  16. Influence of respiratory muscle work on VO(2) and leg blood flow during submaximal exercise.

    PubMed

    Wetter, T J; Harms, C A; Nelson, W B; Pegelow, D F; Dempsey, J A

    1999-08-01

    The work of breathing (W(b)) normally incurred during maximal exercise not only requires substantial cardiac output and O(2) consumption (VO(2)) but also causes vasoconstriction in locomotor muscles and compromises leg blood flow (Q(leg)). We wondered whether the W(b) normally incurred during submaximal exercise would also reduce Q(leg). Therefore, we investigated the effects of changing the W(b) on Q(leg) via thermodilution in 10 healthy trained male cyclists [maximal VO(2) (VO(2 max)) = 59 +/- 9 ml. kg(-1). min(-1)] during repeated bouts of cycle exercise at work rates corresponding to 50 and 75% of VO(2 max). Inspiratory muscle work was 1) reduced 40 +/- 6% via a proportional-assist ventilator, 2) not manipulated (control), or 3) increased 61 +/- 8% by addition of inspiratory resistive loads. Increasing the W(b) during submaximal exercise caused VO(2) to increase; decreasing the W(b) was associated with lower VO(2) (DeltaVO(2) = 0.12 and 0.21 l/min at 50 and 75% of VO(2 max), respectively, for approximately 100% change in W(b)). There were no significant changes in leg vascular resistance (LVR), norepinephrine spillover, arterial pressure, or Q(leg) when W(b) was reduced or increased. Why are LVR, norepinephrine spillover, and Q(leg) influenced by the W(b) at maximal but not submaximal exercise? We postulate that at submaximal work rates and ventilation rates the normal W(b) required makes insufficient demands for VO(2) and cardiac output to require any cardiovascular adjustment and is too small to activate sympathetic vasoconstrictor efferent output. Furthermore, even a 50-70% increase in W(b) during submaximal exercise, as might be encountered in conditions where ventilation rates and/or inspiratory flow resistive forces are higher than normal, also does not elicit changes in LVR or Q(leg).

  17. Model for the Formation and Evolution of Sand Ridges on the Continental Shelf

    DTIC Science & Technology

    1992-10-01

    difficulties of conducting laboratory experiments involving liquid/sediment media (such as leveling the sediment bed after each trial, extracting gas...reflected component, the 54 55 bottom velocities to lowest order are Uob = uo+ 32’.uoxr = E’= 1 Cja(X, y)e(•k’x-W’t) + c.c. (3.3) Vob = VO + 02 2 h(3 Vb2 To

  18. Morphological analysis of the pancreas and liver in diabetic KK-A(y) mice treated with zinc and oxovanadium complexes.

    PubMed

    Moroki, Takayasu; Yoshikawa, Yutaka; Yoshizawa, Katsuhiko; Tsubura, Airo; Yasui, Hiroyuki

    2014-09-01

    The relationship between biometals, such as zinc (Zn(2+)), vanadium, copper, cobalt, and magnesium ions, and diabetes therapy has been recognized for several years. In particular, the antidiabetic activities of Zn(2+) and oxovanadium (VO(2+)) complexes have been measured using biochemical approaches. In the present study, diabetic KK-A(y) mice were treated with bis(1-oxy-2-pyridine-thiolato)Zn(2+) (Zn(opt)2) and bis(1-oxy-2-pyridine-thiolato)VO(2+) (VO(opt)2) for 4 weeks, and the antidiabetic activities of these metal complexes were evaluated using biochemical and morphological methods. Additionally, zinc gluconate (Zn(glc)2) and bis(ethylmaltolato)VO(2+) (VO(emal)2) were used as reference compounds. Pancreatic islet cells were smaller, and there was a tendency towards a lower islet cell area ratio in Zn(opt)2-treated mice compared with nontreated KK-A(y) mice. Furthermore, plasma insulin concentrations were significantly reduced to 27.2% of insulin concentrations in nontreated KK-A(y) mice. These results suggest that Zn(opt)2 administration provides morphological and biochemical improvements in hyperinsulinaemia. In contrast, in mice that received Zn(glc)2 and VO(2+) complexes, the islet cell size and islet cell area ratio did not differ from those in nontreated controls. Zn(opt)2- and VO(opt)2-treated mice exhibited significantly lower fat deposition and fat deposition area ratio in the liver (63.6% and 65.8% of nontreated KK-A(y) mice, respectively) compared to those observed in nontreated KK-A(y) mice. The differences in morphological improvements of the pancreas and liver owing to Zn(opt)2 or VO(opt)2 treatment may be explained by differences in the sites of actions of Zn(2+) and VO(2+) complexes in different organs in KK-A(y) mice. In conclusion, Zn(opt)2 exhibited superior antidiabetic effects over those of VO(opt)2, and this was owing to greater amelioration of the morphological parameters of the liver and pancreas.

  19. Oxygen uptake and body composition after aquatic physical training in women with fibromyalgia: a randomized controlled trial.

    PubMed

    Andrade, Carolina P; Zamunér, Antonio R; Forti, Meire; França, Thalita F; Tamburús, Nayara Y; Silva, Ester

    2017-10-01

    Aquatic physical training (APT) has been strongly recommended to improve symptoms in fibromyalgia syndrome (FMS). However, its effects on body composition and whether lean body mass (LBM) directly influences the aerobic functional capacity of this population are still not clear. To investigate whether APT can help improve body composition and increase the aerobic functional capacity in women with FMS, and whether oxygen uptake (VO2) related to LBM can better quantify the functional capacity of this population. Randomized controlled trial. The Federal University of São Carlos, São Paulo, Brazil. Fifty-four women with FMS were randomly assigned to trained group (TG, N.=27) or control group (CG, N.=27). All women underwent cardiopulmonary exercise test (CPET) to assess oxygen consumption at ventilatory anaerobic threshold (VAT) and at peak exercise, and also to assess body composition. The TG was submitted to APT program, held twice a week for 16 weeks. The exercise intensity was adapted throughout the sessions in order to keep heart rate and ratings of perceived exertion achieved at VAT. After APT, body composition was not significantly different between groups (TG and CG). In VAT only TG showed increased VO2 related to LBM, since in peak CPET, VO2 in absolute units, VO2 related to total body mass (TBM), VO2 related to LBM and power showed significant differences. Significant difference between VO2 related to TBM and VO2 related to baseline LBM and after 16 weeks of follow-up, both in VAT as in peak CPET in both groups. Significant difference between VO2 related to TBM and VO2 related to LBM at VAT and at peak CPET in both groups at baseline and after 16 weeks of follow-up was observed. APT with standardized intensities did not cause significant changes in body composition, but was effective in promoting increased VO2 at peak CPET in women with FMS. However, VO2 related to LBM more accurately reflected changes in aerobic functional capacity at VAT level after to APT. APT with standardized intensities at VAT level is of great interest, since VAT reflects better aerobic functional capacity of patients with FMS than maximum VO2.

  20. Submaximal exercise VO2 and Qc during 30-day 6 degrees head-down bed rest with isotonic and isokinetic exercise training

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Ertl, A. C.; Bernauer, E. M.

    1996-01-01

    BACKGROUND: Maintaining intermediary metabolism is necessary for the health and well-being of astronauts on long-duration spaceflights. While peak oxygen uptake (VO2) is consistently decreased during prolonged bed rest, submaximal VO2 is either unchanged or decreased. METHODS: Submaximal exercise metabolism (61 +/- 3% peak VO2) was measured during ambulation (AMB day-2) and on bed rest days 4, 11, and 25 in 19 healthy men (32-42 yr) allocated into no exercise (NOE, N = 5) control, and isotonic exercise (ITE, N = 7) and isokinetic exercise (IKE, N = 7) training groups. Exercise training was conducted supine for two 30-min periods per day for 6 d per week: ITE training was intermittent at 60-90% peak VO2; IKE training was 10 sets of 5 repetitions of peak knee flexion-extension force at a velocity of 100 degrees s-1. Cardiac output was measured with the indirect Fick CO2 method, and plasma volume with Evans blue dye dilution. RESULTS: Supine submaximal exercise VO2 decreased significantly (*p < 0.05) by 10.3%* with ITE and by 7.3%* with IKE; similar to the submaximal cardiac output decrease of 14.5%* (ITE) and 20.3%* (IKE), but different from change in peak VO2 (+1.4% with ITE and -10.2%* with IKE) and decrease in plasma volume of -3.7% (ITE) and -18.0%* (IKE). Reduction of submaximal VO2 during bed rest correlated 0.79 (p < 0.01) with submaximal Qc, but was not related to change in peak VO2 or plasma volume. CONCLUSION: Reduction in submaximal oxygen uptake during prolonged bed rest is related to decrease in exercise but not resting cardiac output; perturbations in active skeletal muscle metabolism may be involved.

  1. Maximum Oxygen Uptake During and After Long-Duration Space Flight

    NASA Technical Reports Server (NTRS)

    Moore, Alan D., Jr.; Evetts, Simon N.; Feiveson, Alan H.; Lee, Stuart M. C.; McCleary. Frank A.; Platts, Steven H.

    2010-01-01

    Decreased maximum oxygen consumption (VO2max) during and after space flight may impair a crewmember s ability to perform mission-critical work that is high intensity and/or long duration in nature (Human Research Program Integrated Research Plan Risk 2.1.2: Risk of Reduced Physical Performance Capabilities Due to Reduced Aerobic Capacity). When VO2max was measured in Space Shuttle experiments, investigators reported that it did not change during short-duration space flight but decreased immediately after flight. Similar conclusions, based on the heart rate (HR) response of Skylab crewmembers, were made previously concerning long-duration space flight. Specifically, no change in the in-flight exercise HR response in 8 of 9 Skylab crewmembers indicated that VO2max was maintained during flight, but the elevated exercise HR after flight indicated that VO2max was decreased after landing. More recently, a different pattern of in-flight exercise HR response, and assumed changes in VO2max, emerged from routine testing of International Space Station (ISS) crewmembers. Most ISS crewmembers experience an elevated in-flight exercise HR response early in their mission, with a gradual return toward preflight levels as the mission progresses. Similar to previous reports, exercise HR is elevated after ISS missions and returns to preflight levels by 30 days after landing. VO2max has not been measured either during or after long-duration space flight. The purposes of the ISS VO2max experiment are (1) to measure VO2max during and after long-duration spaceflight, and (2) to determine if submaximal exercise test results can be used to accurately estimate VO 2max.

  2. Improved photoelectrochemical performance of BiVO4/MoO3 heterostructure thin films

    NASA Astrophysics Data System (ADS)

    Kodan, Nisha; Mehta, B. R.

    2018-05-01

    Bismuth vanadate (BiVO4) and Molybdenum trioxide (MoO3) thin films have been prepared by RF sputtering technique. BiVO4 thin films were deposited on indium doped tin oxide (In: SnO2; ITO) substrates at room temperature and 80W applied rf power. The prepared BiVO4 thin films were further annealed at 450°C for 2 hours in air to obtain crystalline monoclinic phase and successively coated with MoO3 thin films deposited at 150W rf power and 400°C for 30 minutes. The effect of coupling BiVO4 and MoO3 on the structural, optical and photoelectrochemical (PEC) properties have been studied. Optical studies reveal that coupling of BiVO4 and MoO3 results in improvement of optical absorption in visible region of solar spectrum. PEC study shows approximate 3-fold and 38-fold increment in photocurrent values of BiVO4/MoO3 (0.38 mA/cm2) heterostructure thin film as compared to MoO3 (0.15 mA/cm2) and BiVO4 (10 µA/cm2) thin films at applied bias of 1 V vs Ag/AgCl in 0.5 M Na2SO4 (pH=7) electrolyte.

  3. Sapphire substrate-induced effects in VO2 thin films grown by oxygen plasma-assisted pulsed laser deposition

    NASA Astrophysics Data System (ADS)

    Skuza, J. R.; Scott, D. W.; Pradhan, A. K.

    2015-11-01

    We investigate the structural and electronic properties of VO2 thin films on c-plane sapphire substrates with three different surface morphologies to control the strain at the substrate-film interface. Only non-annealed substrates with no discernible surface features (terraces) provided a suitable template for VO2 film growth with a semiconductor-metal transition (SMT), which was much lower than the bulk transition temperature. In addition to strain, oxygen vacancy concentration also affects the properties of VO2, which can be controlled through deposition conditions. Oxygen plasma-assisted pulsed laser deposition allows favorable conditions for VO2 film growth with SMTs that can be easily tailored for device applications.

  4. Supercritical temperature synthesis of fluorine-doped VO2(M) nanoparticle with improved thermochromic property

    NASA Astrophysics Data System (ADS)

    Riapanitra, Anung; Asakura, Yusuke; Cao, Wenbin; Noda, Yasuto; Yin, Shu

    2018-06-01

    Fluorine-doped VO2(M) nanoparticles have been successfully synthesized using the hydrothermal method at a supercritical temperature of 490 °C. The pristine VO2(M) has the critical phase transformation temperature of 64 °C. The morphology and homogeneity of the monoclinic structure VO2(M) were adopted by the fluorine-doped system. The obtained particle size of the samples is smaller at the higher concentration of anion doping. The best reduction of critical temperature was achieved by fluorine doping of 0.13% up to 48 °C. The thin films of the fluorine-doped VO2(M) showed pronounced thermochromic property and therefore are suitable for smart window applications.

  5. [Is physical activity an elixir?].

    PubMed

    Lacza, Gyöngyvér; Radák, Zsolt

    2013-05-19

    Physical exercise has systemic effects, and it can regulate all the organs. The relative maximal aerobic oxygen uptake (VO2max) could have been important in the evolution of humans, since higher VO2max meant better hunting abilities for the Stone Age man. However, it appears that high level of VO2max is also important today, in the 21st century to prevent cardiovascular diseases, cancer and neurodegenerative diseases. High level of VO2max is not just preventive against a wide spectrum of diseases, but it associated with better function of many organs. Relevant data suggest that high level of VO2max is a key factor in prevention of diseases and survival even at the modern civilized world.

  6. Coherently coupled ZnO and VO2 interface studied by photoluminescence and electrical transport across a phase transition

    NASA Astrophysics Data System (ADS)

    Srivastava, Amar; Herng, T. S.; Saha, Surajit; Nina, Bao; Annadi, A.; Naomi, N.; Liu, Z. Q.; Dhar, S.; Ariando; Ding, J.; Venkatesan, T.

    2012-06-01

    We have investigated the photoluminescence and electrical properties of a coherently coupled interface consisting of a ZnO layer grown on top of an oriented VO2 layer on sapphire across the phase transition of VO2. The band edge and defect luminescence of the ZnO overlayer exhibit hysteresis in opposite directions induced by the phase transition of VO2. Concomitantly the phase transition of VO2 was seen to induce defects in the ZnO layer. Such coherently coupled interfaces could be of use in characterizing the stability of a variety of interfaces in situ and also for novel device application.

  7. Flexible 3D Fe@VO2 core-shell mesh: A highly efficient and easy-recycling catalyst for the removal of organic dyes.

    PubMed

    Li, Jing; Wang, Ruoqi; Su, Zhen; Zhang, Dandan; Li, Heping; Yan, Youwei

    2018-10-01

    Nowadays, it is extremely urgent to search for efficient and effective catalysts for water purification due to the severe worldwide water-contamination crises. Here, 3D Fe@VO 2 core-shell mesh, a highly efficient catalyst toward removal of organic dyes with excellent recycling ability in the dark is designed and developed for the first time. This novel core-shell structure is actually 304 stainless steel mesh coated by VO 2 , fabricated by an electrophoretic deposition method. In such a core-shell structure, Fe as the core allows much easier separation from the water, endowing the catalyst with a flexible property for easy recycling, while VO 2 as the shell is highly efficient in degradation of organic dyes with the addition of H 2 O 2 . More intriguingly, the 3D Fe@VO 2 core-shell mesh exhibits favorable performance across a wide pH range. The 3D Fe@VO 2 core-shell mesh can decompose organic dyes both in a light-free condition and under visible irradiation. The possible catalytic oxidation mechanism of Fe@VO 2 /H 2 O 2 system is also proposed in this work. Considering its facile fabrication, remarkable catalytic efficiency across a wide pH range, and easy recycling characteristic, the 3D Fe@VO 2 core-shell mesh is a newly developed high-performance catalyst for addressing the universal water crises. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Electro-thermal control of aluminum-doped zinc oxide/vanadium dioxide multilayered thin films for smart-device applications

    PubMed Central

    Skuza, J. R.; Scott, D. W.; Mundle, R. M.; Pradhan, A. K.

    2016-01-01

    We demonstrate the electro-thermal control of aluminum-doped zinc oxide (Al:ZnO) /vanadium dioxide (VO2) multilayered thin films, where the application of a small electric field enables precise control of the applied heat to the VO2 thin film to induce its semiconductor-metal transition (SMT). The transparent conducting oxide nature of the top Al:ZnO film can be tuned to facilitate the fine control of the SMT of the VO2 thin film and its associated properties. In addition, the Al:ZnO film provides a capping layer to the VO2 thin film, which inhibits oxidation to a more energetically favorable and stable V2O5 phase. It also decreases the SMT of the VO2 thin film by approximately 5–10 °C because of an additional stress induced on the VO2 thin film and/or an alteration of the oxygen vacancy concentration in the VO2 thin film. These results have significant impacts on technological applications for both passive and active devices by exploiting this near-room-temperature SMT. PMID:26884225

  9. Effect of oxygen partial pressure and VO2 content on hexagonal WO3 thin films synthesized by pulsed laser deposition technique

    NASA Astrophysics Data System (ADS)

    Kaushal, Ajay; Kaur, Davinder

    2011-06-01

    We report on the effect of oxygen partial pressure and vacuum annealing on structural and optical properties of pulsed laser-deposited nanocrystalline WO3 thin films. XRD results show the hexagonal phase of deposited WO3 thin films. The crystallite size was observed to increase with increase in oxygen partial pressure. Vacuum annealing changed the transparent as-deposited WO3 thin film to deep shade of blue color which increases the optical absorption of the film. The origin of this blue color could be due to the presence of oxygen vacancies associated with tungsten ions in lower oxidation states. In addition, the effects of VO2 content on structural, electrochemical, and optical properties of (WO3)1- x (VO2) x nanocomposite thin films have also been systematically investigated. Cyclic voltammogram exhibits a modification with the appearance of an extra cathodic peak for VO2-WO3 thin film electrode with higher VO2 content ( x ≥ 0.2). Increase of VO2 content in (WO3)1- x (VO2) x films leads to red shift in optical band gap.

  10. Synthesis of β-AgVO3 nanowires decorated with Ag2CrO4, with improved visible light photocatalytic performance

    NASA Astrophysics Data System (ADS)

    Ouyang, Qi; Li, Zhonghua; Liu, Jiawen

    2018-05-01

    Silver chromate‑silver vanadate (Ag2CrO4/β-AgVO3) heterojunction composites are synthesized through a facile precipitation process. The Ag2CrO4/β-AgVO3 hybrids obtained exhibit better photocatalytic activity in degradation of RhB than both pure Ag2CrO4 and β-AgVO3 under visible light irradiation. The 20 wt% Ag2CrO4/β-AgVO3 heterojunction possesses the best photocatalytic ability for degrading RhB: 24.4 times that of pristine β-AgVO3 nanowires and 3.2 times that of individual Ag2CrO4 particles. The phase of the nanocomposites was analyzed using x-ray diffraction as well as x-ray photoelectron spectroscopy. Their morphology was observed via scanning electron microscopy and transmission electron microscopy. The improvement in photocatalytic performance is chiefly ascribed to the synergies between Ag2CrO4/β-AgVO3 heterostructure, which can enhance the light absorbance ability and also accelerate the separation and transfer of photoinduced electrons and holes under visible light irradiation; this is also confirmed by UV–vis diffuse reflection spectrometry and fluorescence emission spectra.

  11. Single muscle fiber adaptations with marathon training.

    PubMed

    Trappe, Scott; Harber, Matthew; Creer, Andrew; Gallagher, Philip; Slivka, Dustin; Minchev, Kiril; Whitsett, David

    2006-09-01

    The purpose of this investigation was to characterize the effects of marathon training on single muscle fiber contractile function in a group of recreational runners. Muscle biopsies were obtained from the gastrocnemius muscle of seven individuals (22 +/- 1 yr, 177 +/- 3 cm, and 68 +/- 2 kg) before, after 13 wk of run training, and after 3 wk of taper. Slow-twitch myosin heavy chain [(MHC) I] and fast-twitch (MHC IIa) muscle fibers were analyzed for size, strength (P(o)), speed (V(o)), and power. The run training program led to the successful completion of a marathon (range 3 h 56 min to 5 h 35 min). Oxygen uptake during submaximal running and citrate synthase activity were improved (P < 0.05) with the training program. Muscle fiber size declined (P < 0.05) by approximately 20% in both fiber types after training. P(o) was maintained in both fiber types with training and increased (P < 0.05) by 18% in the MHC IIa fibers after taper. This resulted in >60% increase (P < 0.05) in force per cross-sectional area in both fiber types. Fiber V(o) increased (P < 0.05) by 28% in MHC I fibers with training and was unchanged in MHC IIa fibers. Peak power increased (P < 0.05) in MHC I and IIa fibers after training with a further increase (P < 0.05) in MHC IIa fiber power after taper. These data show that marathon training decreased slow-twitch and fast-twitch muscle fiber size but that it maintained or improved the functional profile of these fibers. A taper period before the marathon further improved the functional profile of the muscle, which was targeted to the fast-twitch muscle fibers.

  12. Coherent control of optical absorption and the energy transfer pathway of an infrared quantum dot hybridized with a VO2 nanoparticle

    NASA Astrophysics Data System (ADS)

    Hatef, Ali; Zamani, Naser; Johnston, William

    2017-04-01

    We systematically investigate the optical response of a semiconductor quantum dot (QD) hybridized with a vanadium dioxide nanoparticle (VO2NP) in the infrared (IR) region. The VO2NP features a semiconductor to metal phase change characteristic below and above a critical temperature that leads to an abrupt change in the particle’s optical properties. This feature means that the QD-VO2NP hybrid system can support the coherent coupling of exciton-polaritons and exciton-plasmon polaritons in the semiconductor and metal phases of the VO2NP, respectively. In our calculations, the VO2NP phase transition is modelled with a filling fraction (f), representing the fraction of the VO2NP in the metallic phase. The phase transition is driven by the hybrid system’s interaction with a continuous wave (CW) IR laser field. In this paper, we show how control over the filling fraction results in the enhancement or suppression of the QD’s linear absorption. These variations in the QD absorption is due to dramatic changes in the effective local field experienced by the QD and the non-radiative energy transfer from the QD to the VO2NP. The presented results have the potential to be applied to the design of thermal sensors at the nanoscale.

  13. Growth temperature-dependent metal–insulator transition of vanadium dioxide epitaxial films on perovskite strontium titanate (111) single crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Liangxin; Zhao, Jiangtao; Hong, Bin

    2016-04-14

    Vanadium dioxide (VO{sub 2}) epitaxial films were grown on perovskite single-crystal strontium titanate (SrTiO{sub 3}) substrates by reactive radio-frequency magnetron sputtering. The growth temperature-dependent metal–insulator transition (MIT) behavior of the VO{sub 2} epitaxial films was then investigated. We found that the order of magnitude of resistance change across the MIT increased from 10{sup 2} to 10{sup 4} with increasing growth temperature. In contrast, the temperature of the MIT does not strongly depend on the growth temperature and is fairly stable at about 345 K. On one hand, the increasing magnitude of the MIT is attributed to the better crystallinity and thusmore » larger grain size in the (010)-VO{sub 2}/(111)-SrTiO{sub 3} epitaxial films at elevated temperature. On the other hand, the strain states do not change in the VO{sub 2} films deposited at various temperatures, resulting in stable V-V chains and V-O bonds in the VO{sub 2} epitaxial films. The accompanied orbital occupancy near the Fermi level is also constant and thus the MIT temperatures of VO{sub 2} films deposited at various temperatures are nearly the same. This work demonstrates that high-quality VO{sub 2} can be grown on perovskite substrates, showing potential for integration into oxide heterostructures and superlattices.« less

  14. Synthesis of novel CeO2-BiVO4/FAC composites with enhanced visible-light photocatalytic properties.

    PubMed

    Zhang, Jin; Wang, Bing; Li, Chuang; Cui, Hao; Zhai, Jianping; Li, Qin

    2014-09-01

    To utilize visible light more effectively in photocatalytic reactions, a fly ash cenosphere (FAC)-supported CeO2-BiVO4 (CeO2-BiVO4/FAC) composite photocatalyst was prepared by modified metalorganic decomposition and impregnation methods. The physical and photophysical properties of the composite have been characterized by X-ray diffraction (XRD), scanning electron microscope (SEM) and energy dispersive X-ray spectroscopy (EDX), X-ray photoelectron spectroscopy (XPS), and UV-Visible diffuse reflectance spectra. The XRD patterns exhibited characteristic diffraction peaks of both BiVO4 and CeO2 crystalline phases. The XPS results showed that Ce was present as both Ce(4+) and Ce(3+) oxidation states in CeO2 and dispersed on the surface of BiVO4 to constitute a p-n heterojunction composite. The absorption threshold of the CeO2-BiVO4/FAC composite shifted to a longer wavelength in the UV-Vis absorption spectrum compared to the pure CeO2 and pure BiVO4. The composites exhibited enhanced photocatalytic activity for Methylene Blue (MB) degradation under visible light irradiation. It was found that the 7.5wt.% CeO2-BiVO4/FAC composite showed the highest photocatalytic activity for MB dye wastewater treatment. Copyright © 2014. Published by Elsevier B.V.

  15. Structure and enhanced thermochromic performance of low-temperature fabricated VO 2/V 2O 3 thin film

    DOE PAGES

    Sun, Guangyao; Cao, Xun; Gao, Xiang; ...

    2016-10-06

    For VO 2-based smart window manufacture, it is a long-standing demand for high-quality thin films deposited at low temperature. In this paper, the thermochromic films of VO 2 were deposited by a magnetron sputtering method at a fairly low temperature of 250 °C without subsequent annealing by embedding a V 2O 3 interlayer. V 2O 3 acts as a seed layer to lower the depositing temperature and buffer layer to epitaxial grow VO 2 film. The VO 2/V 2O 3 films display high solar modulating ability and narrow hysteresis loop. Finally, our data can serve as a promising point formore » industrial production with high degree of crystallinity at a low temperature.« less

  16. Epitaxial VO2 thin-film-based radio-frequency switches with electrical activation

    NASA Astrophysics Data System (ADS)

    Lee, Jaeseong; Lee, Daesu; Cho, Sang June; Seo, Jung-Hun; Liu, Dong; Eom, Chang-Beom; Ma, Zhenqiang

    2017-09-01

    Vanadium dioxide (VO2) is a correlated material exhibiting a sharp insulator-to-metal phase transition (IMT) caused by temperature change and/or bias voltage. We report on the demonstration of electrically triggered radio-frequency (RF) switches based on epitaxial VO2 thin films. The highly epitaxial VO2 and SnO2 template layer was grown on a (001) TiO2 substrate by pulsed laser deposition (PLD). A resistance change of the VO2 thin films of four orders of magnitude was achieved with a relatively low threshold voltage, as low as 13 V, for an IMT phase transition. VO2 RF switches also showed high-frequency responses of insertion losses of -3 dB at the on-state and return losses of -4.3 dB at the off-state over 27 GHz. Furthermore, an intrinsic cutoff frequency of 17.4 THz was estimated for the RF switches. The study on electrical IMT dynamics revealed a phase transition time of 840 ns.

  17. High-intensity Interval Training Dosage for Heart Failure and Coronary Artery Disease Cardiac Rehabilitation. A Systematic Review and Meta-analysis.

    PubMed

    Ballesta García, Ismael; Rubio Arias, Jacobo Ángel; Ramos Campo, Domingo Jesús; Martínez González-Moro, Ignacio; Carrasco Poyatos, María

    2018-04-09

    High-interval intensity training (HIT) has been suggested to improve peak VO 2 in cardiac rehabilitation programs. However, the optimal HIT protocol is unknown. The objective of this study was to identify the most effective doses of HIT to optimize peak VO 2 in coronary artery disease (CAD) and heart failure (HF) patients. A search was conducted in 6 databases (MEDLINE, Web of Science, LILACS, CINAHL, Academic Search Complete, and SportDiscus). Studies using a HIT protocol in CAD or HF patients and measuring peak VO 2 were included. The PEDro Scale and Cochrane Collaboration tools were used. Analyses reported significant improvements in peak VO 2 after HIT in both diseases (P = .000001), with a higher increase in HF patients (P = .03). Nevertheless, in HF patients, there were no improvements when the intensity recovery was ≤ 40% of peak VO 2 (P = .19) and the frequency of training was ≤ 2 d/wk (P = .07). There were significant differences regarding duration in CAD patients, with greater improvements in peak VO 2 when the duration was < 12 weeks (P = .05). In HF, programs lasting < 12 weeks did not significantly improve peak VO 2 (P = .1). The HIT is an effective method for improving peak VO 2 in HF and CAD, with a significantly greater increase in HF patients. The recovery intervals should be active and be between 40% and 60% of peak VO 2 in HF patients. Training frequency should be ≥ 2 d/wk for CAD patients and ≥ 3 d/wk for HF patients. Copyright © 2018 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  18. Inverse relationship between VO2max and economy/efficiency in world-class cyclists.

    PubMed

    Lucía, Alejandro; Hoyos, Jesus; Pérez, Margarita; Santalla, Alfredo; Chicharro, José L

    2002-12-01

    To determine the relationship that exists between VO2max and cycling economy/efficiency during intense, submaximal exercise in world-class road professional cyclists. METHODS Each of 11 male cyclists (26+/-1 yr (mean +/- SEM); VO2max: 72.0 +/- 1.8 mL x kg(-1) x min(-1)) performed: 1) a ramp test for O2max determination and 2) a constant-load test of 20-min duration at the power output eliciting 80% of subjects' VO2max during the previous ramp test (mean power output of 385 +/- 7 W). Cycling economy (CE) and gross mechanical efficiency (GE) were calculated during the constant-load tests. CE and GE averaged 85.2 +/- 2.3 W x L(-1) x min(-1) and 24.5 +/- 0.7%, respectively. An inverse, significant correlation was found between 1) VO2max (mL x kg(-0.32) x min(-1)) and both CE (r = -0.71; P = 0.01) and GE (-0.72; P = 0.01), and 2) VO2max (mL x kg(-1) x min(-1)) and both CE (r = -0.65; P = 0.03) and GE (-0.64; P = 0.03). A high CE/GE seems to compensate for a relatively low VO2max in professional cyclists.

  19. The aerobic demand of backstroke swimming, and its relation to body size, stroke technique, and performance.

    PubMed

    Smith, H K; Montpetit, R R; Perrault, H

    1988-01-01

    Few studies have examined the aerobic demand of backstroke swimming, and its relation to body morphology, technique, or performance. The aims of this study were thus to: i) describe the aerobic demand of backstroke swimming in proficient swimmers at high velocities; ii) assess the effects of body size and stroke technique on submaximal and maximal O2 costs, and; iii) test for a relationship between submaximal O2 costs and maximal performance. Sixteen male competitive swimmers were tested during backstroke swimming at velocities from 1.0 to 1.4 m.s-1. Results showed that VO2 increased linearly with velocity (m.s-1) following the equation VO2 = 6.28v - 3.81 (r = 0.77, SEE/Y = 14.9%). VO2 was also related to the subjects' body mass, height, and armspan. Longer distances per stroke were associated with lower O2 costs, and better maximal performances. A significant relation was found between VO2 at 1.1 m.s-1, adjusted for body mass, and 400 m performance (r = -0.78). Submaximal VO2 was also related to reported times for 100 m and 200 m races. Multiple correlation analyses indicated that VO2 at 1.1 m.s-1 and VO2max accounted for up to 78% of the variance in maximal performances. These results suggest that the assessment of submaximal and maximal VO2 during backstroke swimming may be of value in the training and testing programs of competitive swimmers.

  20. Thermally tunable VO2-SiO2 nanocomposite thin-film capacitors

    NASA Astrophysics Data System (ADS)

    Sun, Yifei; Narayanachari, K. V. L. V.; Wan, Chenghao; Sun, Xing; Wang, Haiyan; Cooley, Kayla A.; Mohney, Suzanne E.; White, Doug; Duwel, Amy; Kats, Mikhail A.; Ramanathan, Shriram

    2018-03-01

    We present a study of co-sputtered VO2-SiO2 nanocomposite dielectric thin-film media possessing continuous temperature tunability of the dielectric constant. The smooth thermal tunability is a result of the insulator-metal transition in the VO2 inclusions dispersed within an insulating matrix. We present a detailed comparison of the dielectric characteristics of this nanocomposite with those of a VO2 control layer and of VO2/SiO2 laminate multilayers of comparable overall thickness. We demonstrated a nanocomposite capacitor that has a thermal capacitance tunability of ˜60% between 25 °C and 100 °C at 1 MHz, with low leakage current. Such thermally tunable capacitors could find potential use in applications such as sensing, thermal cloaks, and phase-change energy storage devices.

  1. Thermochromic VO2 Films Deposited by RF Magnetron Sputtering Using V2O3 or V2O5 Targets

    NASA Astrophysics Data System (ADS)

    Shigesato, Yuzo; Enomoto, Mikiko; Odaka, Hidehumi

    2000-10-01

    Thermochromic monoclinic-tetragonal VO2 films were successfully deposited on glass substrates with high reproducibility by rf magnetron sputtering using V2O3 or V2O5 targets. In the case of reactive sputtering using a V-metal target, the VO2 films could be obtained only under the very narrow deposition conditions of the “transition region” where the deposition rate decreases drastically with increasing oxygen gas flow rate. In the case of a V2O3 target, polycrystalline VO2 films with a thickness of 400 to 500 nm were obtained by the introduction of oxygen gas [O2/(Ar+O2)=1--1.5%], whereas hydrogen gas [H2/(Ar+H2)=2.5--10%] was introduced in the case of a V2O5 target. Furthermore, the VO2 films were successfully grown heteroepitaxially on a single-crystal sapphire [α-Al2O3(001)] substrate, where the epitaxial relationship was confirmed to be VO2(010)[100]\\parallelAl2O3(001)[100], [010], [\\bar{1}\\bar{1}0] by an X-ray diffraction pole figure measurement. The resistivity ratio between semiconductor and metal phases for the heteroepitaxial VO2 films was much larger than the ratio of the polycrystalline films on glass substrates under the same deposition conditions.

  2. Controllable one-pot synthesis of a nest-like Bi2WO6/BiVO4 composite with enhanced photocatalytic antifouling performance under visible light irradiation.

    PubMed

    Ju, Peng; Wang, Yi; Sun, Yan; Zhang, Dun

    2016-03-21

    In this study, a novel visible-light-sensitive Bi2WO6/BiVO4 composite photocatalyst was controllably synthesized through a facile one-pot hydrothermal method. The Bi2WO6/BiVO4 composite exhibited a perfect nest-like hierarchical microsphere structure, which was constructed by the self-assembly of nanoplates with the assistance of polyvinylpyrrolidone (PVP). The growth mechanism of the Bi2WO6/BiVO4 composite and the effect of its structure on its photocatalytic performance was investigated and proposed. Experimental results showed that the Bi2WO6/BiVO4 composites displayed enhanced photocatalytic antifouling activities under visible light irradiation compared to pure Bi2WO6 and BiVO4. Bi2WO6/BiVO4-1 exhibited the best photocatalytic antifouling performance, and almost all (99.99%) Pseudomonas aeruginosa (P. aeruginosa), Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus) bacteria were killed within 30 min. Moreover, the Bi2WO6/BiVO4-1 composite exhibited excellent stability and reusability in the cycled experiments. The photocatalytic antifouling mechanism was proposed based on the active species trapping experiments, revealing that the photo-induced holes (h(+)) and hydroxyl radicals (˙OH) could attack the cell wall and cytoplasmic membrane directly and lead to the death of bacteria. The obviously enhanced photocatalytic activity of the Bi2WO6/BiVO4-1 composite could be mainly attributed to the formation of heterojunctions, accelerating the separation of photo-induced electrons and holes. Furthermore, the large BET surface area combined with the wide photoabsorption region further improved the photocatalytic performance of the Bi2WO6/BiVO4-1 composite. This study provides a new strategy to develop novel composite photocatalysts with enhanced photocatalytic performance for marine antifouling and water purification.

  3. Dose-response relationship of cardiorespiratory fitness adaptation to controlled endurance training in sedentary older adults.

    PubMed

    Huang, Guoyuan; Wang, Ru; Chen, Peijie; Huang, Sunny C; Donnelly, Joseph E; Mehlferber, Jon P

    2016-03-01

    The purpose of this investigation was to identify a quantitative dose-response relationship for enhancing maximal oxygen consumption (VO2max) in healthy sedentary older adults after controlled endurance training. This meta-analysis of controlled clinical trials included 1257 exercisers and 845 controls with a mean age of 67.45 ± 5.25 years. Effect sizes were calculated for training-induced VO2max changes. Different training regimens were analyzed and compared. The weighted net change of the mean VO2max values showed a significant increase of 3.78 ml/kg per min (95% confidence interval = 3.29 to 4.27; p < 0.0001) in response to aerobic training. Interstudy differences in VO2max changes were significantly related to exercise intensity, and explained approximately 11% of the variance of the VO2max responses. VO2max improved significantly at 35%-50% heart rate reserve (HRR) and continued improving at a greater rate with increasing "dose". The largest VO2max-improvement adaptation was achieved with a mean intensity of 66%-73% HRR. The magnitudes of the VO2max adaptation are identical to exercise at 57%-65% HRR and at 75%-80% HRR. Higher intensity doses more than 75-80% HRR did not lead to greater enhancement of VO2max improvements but, conversely, resulted in large declines. Our data provide quantitative insight into the magnitude of VO2max alterations as affected by exercise intensity, duration, frequency, and program length. The shapes of the dose-response curves are not simply linear, but with many similar trends and noteworthy characteristics. Aerobic training at a mean intensity of 66%-73% HRR with 40-50 min per session for 3-4 day/week for 30-40 weeks appears to be effective and optimal for maximum cardiorespiratory benefits in healthy sedentary older adults. © The European Society of Cardiology 2015.

  4. Hemodynamic exercise testing. A valuable tool in the selection of cardiac transplantation candidates.

    PubMed

    Chomsky, D B; Lang, C C; Rayos, G H; Shyr, Y; Yeoh, T K; Pierson, R N; Davis, S F; Wilson, J R

    1996-12-15

    Peak exercise oxygen consumption (Vo2), a noninvasive index of peak exercise cardiac output (CO), is widely used to select candidates for heart transplantation. However, peak exercise Vo2 can be influenced by noncardiac factors such as deconditioning, motivation, or body composition and may yield misleading prognostic information. Direct measurement of the CO response to exercise may avoid this problem and more accurately predict prognosis. Hemodynamic and ventilatory responses to maximal treadmill exercise were measured in 185 ambulatory patients with chronic heart failure who had been referred for cardiac transplantation (mean left ventricular ejection fraction, 22 +/- 7%; mean peak Vo2, 12.9 +/- 3.0 mL. min-1.kg-1). CO response to exercise was normal in 83 patients and reduced in 102. By univariate analysis, patients with normal CO responses had a better 1-year survival rate (95%) than did those with reduced CO responses (72%) (P < .0001). Survival in patients with peak Vo2 of > 14 mL.min-1.kg-1 (88%) was not different from that of patients with peak Vo2 of < or = 14 mL.min-1.kg-1 (79%) (P = NS). However, survival was worse in patients with peak Vo2 of < or = 10 mL.min-1.kg-1 (52%) versus those with peak Vo2 of > 10 mL.min-1.kg-1 (89%) (P < .0001). By Cox regression analysis, exercise CO response was the strongest independent predictor of survival (risk ratio, 4.3), with peak Vo2 dichotomized at 10 mL. min-1.kg-1 (risk ratio, 3.3) as the only other independent predictor. Patients with reduced CO responses and peak Vo2 of < or = 10 mL.min-1.kg-1 had an extremely poor 1-year survival rate (38%). Both CO response to exercise and peak exercise Vo2 provide valuable independent prognostic information in ambulatory patients with heart failure. These variables should be used in combination to select potential heart transplantation candidates.

  5. The development of rating of perceived exertion-based tests of physical working capacity.

    PubMed

    Mielke, Michelle; Housh, Terry J; Malek, Moh H; Beck, Travis W; Schmidt, Richard J; Johnson, Glen O

    2008-01-01

    The purpose of the present study was to use ratings of perceived exertion (RPE) from the Borg (6-20) and OMNI-Leg (0-10) scales to determine the Physical Working Capacity at the Borg and OMNI thresholds (PWC(BORG) and PWC(OMNI)). PWC(BORG) and PWC(OMNI) were compared with other fatigue thresholds determined from the measurement of heart rate (the Physical Working Capacity at the Heart Rate Threshold: PWC(HRT)), and oxygen consumption (the Physical Working Capacity at the Oxygen Consumption Threshold, PWC(VO2)), as well as the ventilatory threshold (VT). Fifteen men and women volunteers (mean age +/- SD = 22 +/- 1 years) performed an incremental test to exhaustion on an electronically braked ergometer for the determination of VO2 peak and VT. The subjects also performed 4 randomly ordered workbouts to exhaustion at different power outputs (ranging from 60 to 206W) for the determination of PWC(BORG), PWC(OMNI), PWC(HRT), and PWC(VO2). The results indicated that there were no significant mean differences among the fatigue thresholds: PWC(BORG) (mean +/- SD = 133 +/- 37W; 67 +/- 8% of VO2 peak), PWC(OMNI) (137 +/- 44W; 68 +/- 9% of VO2 peak), PWC(HRT) (135 +/- 36W; 68 +/- 8% of VO2 peak), PWC(VO2) (145 +/- 41W; 72 +/- 7% of VO2 peak) and VT (131 +/- 45W; 66 +/- 8% of VO2 peak). The results of this study indicated that the mathematical model used to estimate PWC(HRT) and PWC(VO2) can be applied to ratings of perceived exertion to determine PWC(BORG) and PWC(OMNI) during cycle ergometry. Salient features of the PWC(BORG) and PWC(OMNI) tests are that they are simple to administer and require the use of only an RPE scale, a stopwatch, and a cycle ergometer. Furthermore, the power outputs at the PWC(BORG) and PWC(OMNI) may be useful to estimate the VT noninvasively and without the need for expired gas analysis.

  6. Prediction of Cardiorespiratory Fitness by the Six-Minute Step Test and Its Association with Muscle Strength and Power in Sedentary Obese and Lean Young Women: A Cross-Sectional Study

    PubMed Central

    Bonjorno Junior, José Carlos; de Oliveira, Cláudio Ricardo; Luporini, Rafael Luís; Mendes, Renata Gonçalves; Zangrando, Katiany Thais Lopes; Trimer, Renata; Arena, Ross

    2015-01-01

    Impaired cardiorespiratory fitness (CRF) is a hallmark characteristic in obese and lean sedentary young women. Peak oxygen consumption (VO2peak) prediction from the six-minute step test (6MST) has not been established for sedentary females. It is recognized that lower-limb muscle strength and power play a key role during functional activities. The aim of this study was to investigate cardiorespiratory responses during the 6MST and CPX and to develop a predictive equation to estimate VO2peak in both lean and obese subjects. Additionally we aim to investigate how muscle function impacts functional performance. Lean (LN = 13) and obese (OB = 18) women, aged 20–45, underwent a CPX, two 6MSTs, and isokinetic and isometric knee extensor strength and power evaluations. Regression analysis assessed the ability to predict VO2peak from the 6MST, age and body mass index (BMI). CPX and 6MST main outcomes were compared between LN and OB and correlated with strength and power variables. CRF, functional capacity, and muscle strength and power were lower in the OB compared to LN (<0.05). During the 6MST, LN and OB reached ~90% of predicted maximal heart rate and ~80% of the VO2peak obtained during CPX. BMI, age and number of step cycles (NSC) explained 83% of the total variance in VO2peak. Moderate to strong correlations between VO2peak at CPX and VO2peak at 6MST (r = 0.86), VO2peak at CPX and NSC (r = 0.80), as well as between VO2peak, NSC and muscle strength and power variables were found (p<0.05). These findings indicate the 6MST, BMI and age accurately predict VO2peak in both lean and obese young sedentary women. Muscle strength and power were related to measures of aerobic and functional performance. PMID:26717568

  7. Change in VO2max and time trial performance in response to high-intensity interval training prescribed using ventilatory threshold.

    PubMed

    Astorino, Todd A; deRevere, Jamie; Anderson, Theodore; Kellogg, Erin; Holstrom, Patrick; Ring, Sebastian; Ghaseb, Nicholas

    2018-06-19

    Completion of high-intensity interval training (HIIT) leads to significant increases in maximal oxygen uptake (VO 2max ) and oxidative capacity. However, individual responses to HIIT have been identified as approximately 20-40% of individuals show no change in VO 2max , which may be due to the relatively homogeneous approach to implementing HIIT. This study tested the effects of HIIT prescribed using ventilatory threshold (VT) on changes in VO 2max and cycling performance. Fourteen active men and women (age and VO 2max  = 27 ± 8 year and 38 ± 4 mL/kg/min) underwent nine sessions of HIIT, and 14 additional men and women (age and VO 2max  = 22 ± 3 year and 40 ± 5 mL/kg/min) served as controls. Training was performed on a cycle ergometer at a work rate equal to 130%VT and consisted of eight to ten 1 min bouts interspersed with 75 s of recovery. At baseline and post-testing, they completed progressive cycling to exhaustion to determine VO 2max , and on a separate day, a 5 mile cycling time trial. Compared to the control group, HIIT led to significant increases in VO 2max (6%, p = 0.007), cycling performance (2.5%, p = 0.003), and absolute VT (9 W, p = 0.005). However, only 57% of participants revealed meaningful increases in VO 2max and cycling performance in response to training, and two showed no change in either outcome. A greater volume of HIIT may be needed to maximize the training response for all individuals.

  8. VO2 microcrystals as an advanced smart window material at semiconductor to metal transition

    NASA Astrophysics Data System (ADS)

    Basu, Raktima; Magudapathy, P.; Sardar, Manas; Pandian, Ramanathaswamy; Dhara, Sandip

    2017-11-01

    Textured VO2(0 1 1) microcrystals are grown in the monoclinic, M1 phase which undergoes a reversible first order semiconductor to metal transition (SMT) accompanied by a structural phase transition to rutile tetragonal, R phase. Around the phase transition, VO2 also experiences noticeable change in its optical and electrical properties. A change in color of the VO2 micro crystals from white to cyan around the transition temperature is observed, which is further understood by absorption of red light using temperature dependent ultraviolet-visible spectroscopic analysis and photoluminescence studies. The absorption of light in the red region is explained by the optical transition between Hubbard states, confirming the electronic correlation as the driving force for SMT in VO2. The thermochromism in VO2 has been studied for smart window applications so far in the IR region, which supports the opening of the band gap in semiconducting phase; whereas there is hardly any report in the management of visible light. The filtering of blue light along with reflection of infrared above the semiconductor to metal transition temperature make VO2 applicable as advanced smart windows for overall heat management of a closure.

  9. The impact of firefighter personal protective equipment and treadmill protocol on maximal oxygen uptake.

    PubMed

    Lee, Joo-Young; Bakri, Ilham; Kim, Jung-Hyun; Son, Su-Young; Tochihara, Yutaka

    2013-01-01

    This study investigated the effects of firefighter personal protective equipment (PPE) on the determination of maximal oxygen uptake (VO(2max)) while using two different treadmill protocols: a progressive incline protocol (PIP) and a progressive speed protocol (PSP), with three clothing conditions (Light-light clothing; Boots-PPE with rubber boots; Shoes-PPE with running shoes). Bruce protocol with Light was performed for a reference test. Results showed there was no difference in VO(2max) between Bruce Light, PIP Light, and PSP Light. However, VO(2max) was reduced in Boots and Shoes with shortened maximal performance time (7 and 6 min reduced for PIP Boots and Shoes, respectively; 11 and 9 min reduced for PSP Boots and Shoes, respectively), whereas the increasing rate of VO(2) in Boots and Shoes during submaximal exercise was greater compared with Light. Wearing firefighter boots compared with wearing running shoes also significantly affected submaximal VO(2) but not VO(2max). These results suggest that firefighters' maximal performance determined from a typical VO(2max) test without wearing PPE may overestimate the actual performance capability of firefighters wearing PPE.

  10. The Impact of Firefighter Personal Protective Equipment and Treadmill Protocol on Maximal Oxygen Uptake

    PubMed Central

    Lee, Joo-Young; Bakri, Ilham; Kim, Jung-Hyun; Son, Su-Young; Tochihara, Yutaka

    2015-01-01

    This study investigated the effects of firefighter personal protective equipment (PPE) on the determination of maximal oxygen uptake (VO2max) while using two different treadmill protocols: a progressive incline protocol (PIP) and a progressive speed protocol (PSP), with three clothing conditions (Light-light clothing; Boots-PPE with rubber boots; Shoes-PPE with running shoes). Bruce protocol with Light was performed for a reference test. Results showed there was no difference in VO2max between Bruce Light, PIP Light, and PSP Light. However, VO2max was reduced in Boots and Shoes with shortened maximal performance time (7 and 6 min reduced for PIP Boots and Shoes, respectively; 11 and 9 min reduced for PSP Boots and Shoes, respectively), whereas the increasing rate of VO2 in Boots and Shoes during submaximal exercise was greater compared with Light. Wearing firefighter boots compared with wearing running shoes also significantly affected submaximal VO2 but not VO2max. These results suggest that firefighters’ maximal performance determined from a typical VO2max test without wearing PPE may overestimate the actual performance capability of firefighters wearing PPE. PMID:23668854

  11. Investigation of the physical, optical, and photocatalytic properties of CeO2/Fe-doped InVO4 composite

    NASA Astrophysics Data System (ADS)

    Chaison, Jindaporn; Wetchakun, Khatcharin; Wetchakun, Natda

    2017-12-01

    The CeO2/Fe-doped InVO4 composites with various Fe concentrations (0.5, 1.0, 2.0, 5.0 and 6.0 mol%) was synthesized by homogeneous precipitation and hydrothermal methods. The as-synthesized samples were characterized by powder X-ray diffraction (XRD), Brunauer Emmett and Teller (BET)-specific surface area, field emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), and UV-visible diffuse reflectance spectroscopy (DRS). Fe-doping into InVO4 crystal induces the distortion of the crystalline structure, the transformation of InVO4 morphology, and the new energy subband level generation of Fe between the CB and VB edge of InVO4. The electron excitation from the VB to Fe orbitals results in the decreased band gap and the extended absorption of visible-light, and thus enhances its photocatalytic performance. Visible-light-driven photocatalytic degradation of Rhodamine B (RhB) dye in water was used to evaluate the photocatalytic performance of CeO2/Fe-doped InVO4 composites. The results revealed that there is an optimum Fe (5.0 mol %) doping level. The composite with the optimum doping level obtains high photocatalytic activity of CeO2/Fe-doped InVO4 composite compared to pure CeO2 and pure InVO4 host. The increase of photocatalytic activity of CeO2/Fe-doped InVO4 composite was ascribed to the surface area, crystal defect, and band gap energy. Moreover, the photocatalytic enhancement is also because iron ions act as a trapping site, which results in the higher separation efficiency of photogenerated electrons and holes pairs in the CeO2/InVO4 composite. The evaluation of radical scavengers confirmed that hydroxyl radical was the main active species during the photodegradation of RhB. These synergistic effects are responsible for the enhanced photocatalytic activity of CeO2/Fe-doped InVO4 composite. Furthermore, the possible enhanced photocatalytic mechanism of the CeO2/Fe-doped InVO4 composite was also proposed based on the calculation of band position.

  12. Experimental Identification of the Active Site in the Heteronuclear Redox Couples [AlVOx ]+. /CO/N2 O (x=3, 4) by Gas-Phase IR Spectroscopy.

    PubMed

    Debnath, Sreekanta; Knorke, Harald; Schöllkopf, Wieland; Zhou, Shaodong; Asmis, Knut R; Schwarz, Helmut

    2018-06-18

    Cryogenic ion vibrational spectroscopy was used in combination with electronic structure calculations to identify the active site in the oxygen atom transfer reaction [AlVO 4 ] +. +CO→[AlVO 3 ] +. +CO 2 . Infrared photodissociation spectra of messenger-tagged heteronuclear clusters demonstrate that in contrast to [AlVO 4 ] +. , [AlVO 3 ] +. is devoid of a terminal Al-O t unit while the terminal V=O t group remains intact. Thus it is the Al-O t moiety that forms the active site in the [AlVO x ] +. /CO/N 2 O (x=3, 4) redox couples, which is in line with theoretical predictions. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. High-intensity Interval Training Frequency: Cardiometabolic Effects and Quality of Life.

    PubMed

    Stavrinou, Pinelopi S; Bogdanis, Gregory C; Giannaki, Christoforos D; Terzis, Gerasimos; Hadjicharalambous, Marios

    2018-02-01

    The effects of high intensity interval training (HIIT) frequency on cardiometabolic health and quality of life were examined in 35 healthy inactive adults (age: 31.7±2.6 yrs, VO 2 peak: 32.7±7.4 ml·: kg -1 ·: min -1 ). Participants were randomly assigned to a control (CON) and two training groups, which performed 10×60-s cycling at ~83% of peak power, two (HIIT-2) or three times per week (HIIT-3) for eight weeks. Compared with CON, both training regimes resulted in similar improvements in VO 2 peak (HIIT-2: 10.8%, p=0.048, HIIT-3: 13.6%, p=0.017), waist circumference (HIIT-2: -1.4 cm, p=0.048, HIIT-3: -2.4 cm, p=0.028), thigh cross-sectional area (HIIT-2: 11.4 cm 2 , p=0.001, HIIT-3: 9.3 cm 2 , p=0.001) and the physical health component of quality of life (HIIT-2: 8.4, p=0.001, HIIT-3: 12.2, p=0.001). However, HIIT-3 conferred additional health-related benefits by reducing total body and trunk fat percentage (p<0.05, compared with CON), total cholesterol and low-density lipoprotein-cholesterol (p<0.02, compared with CON) and by improving the mental component of quality of life (p=0.045, compared with CON). In conclusion, performing HIIT only twice per week is effective in promoting cardiometabolic health-related adaptations and quality of life in inactive adults. However, higher HIIT frequency is required for an effect on fat deposits, cholesterol and mental component of well-being. © Georg Thieme Verlag KG Stuttgart · New York.

  14. The effects of breathing a helium-oxygen gas mixture on maximal pulmonary ventilation and maximal oxygen consumption during exercise in acute moderate hypobaric hypoxia.

    PubMed

    Ogawa, Takeshi; Calbet, Jose A L; Honda, Yasushi; Fujii, Naoto; Nishiyasu, Takeshi

    2010-11-01

    To test the hypothesis that maximal exercise pulmonary ventilation (VE max) is a limiting factor affecting maximal oxygen uptake (VO2 max) in moderate hypobaric hypoxia (H), we examined the effect of breathing a helium-oxygen gas mixture (He-O(2); 20.9% O(2)), which would reduce air density and would be expected to increase VE max. Fourteen healthy young male subjects performed incremental treadmill running tests to exhaustion in normobaric normoxia (N; sea level) and in H (atmospheric pressure equivalent to 2,500 m above sea level). These exercise tests were carried out under three conditions [H with He-O(2), H with normal air and N] in random order. VO2 max and arterial oxy-hemoglobin saturation (SaO(2)) were, respectively, 15.2, 7.5 and 4.0% higher (all p < 0.05) with He-O(2) than with normal air (VE max, 171.9 ± 16.1 vs. 150.1 ± 16.9 L/min; VO2 max, 52.50 ± 9.13 vs. 48.72 ± 5.35 mL/kg/min; arterial oxyhemoglobin saturation (SaO(2)), 79 ± 3 vs. 76 ± 3%). There was a linear relationship between the increment in VE max and the increment in VO2 max in H (r = 0.77; p < 0.05). When subjects were divided into two groups based on their VO2 max, both groups showed increased VE max and SaO(2) in H with He-O(2), but VO2 max was increased only in the high VO2 max group. These findings suggest that in acute moderate hypobaric hypoxia, air-flow resistance can be a limiting factor affecting VE max; consequently, VO2 max is limited in part by VE max especially in subjects with high VO2 max.

  15. Effects of postdeposition annealing on the metal-insulator transition of VO2-x thin films prepared by RF magnetron sputtering

    NASA Astrophysics Data System (ADS)

    Liu, Shiu-Jen; Su, Yu-Tai; Hsieh, Juang-Hsin

    2014-03-01

    We report the fabrication of textured VO2-x films on c-cut sapphire substrates by postdeposition annealing of V2O3 films prepared by RF magnetron sputtering using V2O3 as the target. Although the prepared VO2-x films are expected to be oxygen-deficient, overoxidation on the film surface was revealed by X-ray photoelectron spectroscopy. The metal-insulator transition (MIT) characteristics of the VO2-x films were investigated. MIT parameters including the transition temperature, transition sharpness, and hysteresis width of the VO2-x films were manipulated by varying the oxygen pressure during postdeposition annealing. The suppression of optical transmittance in the near-infrared region was observed by increasing the temperature through the MIT.

  16. Detection of the change point in oxygen uptake during an incremental exercise test using recursive residuals: relationship to the plasma lactate accumulation and blood acid base balance.

    PubMed

    Zoladz, J A; Szkutnik, Z; Majerczak, J; Duda, K

    1998-09-01

    The purpose of this study was to develop a method to determine the power output at which oxygen uptake (VO2) during an incremental exercise test begins to rise non-linearly. A group of 26 healthy non-smoking men [mean age 22.1 (SD 1.4) years, body mass 73.6 (SD 7.4) kg, height 179.4 (SD 7.5) cm, maximal oxygen uptake (VO2max) 3.726 (SD 0.363) l x min(-1)], experienced in laboratory tests, were the subjects in this study. They performed an incremental exercise test on a cycle ergometer at a pedalling rate of 70 rev x min(-1). The test started at a power output of 30 W, followed by increases amounting to 30 W every 3 min. At 5 min prior to the first exercise intensity, at the end of each stage of exercise protocol, blood samples (1 ml each) were taken from an antecubital vein. The samples were analysed for plasma lactate concentration [La]pl, partial pressure of O2 and CO2 and hydrogen ion concentration [H+]b. The lactate threshold (LT) in this study was defined as the highest power output above which [La-]pl showed a sustained increase of more than 0.5 mmol x l(-1) x step(-1). The VO2 was measured breath-by-breath. In the analysis of the change point (CP) of VO2 during the incremental exercise test, a two-phase model was assumed for the 3rd-min-data of each step of the test: Xi = at(i) + b + epsilon(i) for i = 1,2, ..., T, and E(Xi) > at(i) + b for i = T + 1, ..., n, where X1, ..., Xn are independent and epsilon(i) approximately N(0, sigma2). In the first phase, a linear relationship between VO2 and power output was assumed, whereas in the second phase an additional increase in VO2 above the values expected from the linear model was allowed. The power output at which the first phase ended was called the change point in oxygen uptake (CP-VO2). The identification of the model consisted of two steps: testing for the existence of CP and estimating its location. Both procedures were based on suitably normalised recursive residuals. We showed that in 25 out of 26 subjects it was possible to determine the CP-VO2 as described in our model. The power output at CP-VO2 amounted to 136.8 (SD 31.3) W. It was only 11 W -- non significantly -- higher than the power output corresponding to LT. The VO2 at CP-VO2 amounted to 1.828 (SD 0.356) l x min(-1) was [48.9 (SD 7.9)% VO2max]. The [La-]pl at CP-VO2, amounting to 2.57 (SD 0.69) mmol x l(-1) was significantly elevated (P < 0.01) above the resting level [1.85 (SD 0.46) mmol x l(-1)], however the [H+]b at CP-VO2 amounting to 45.1 (SD 3.0) nmol x l(-1), was not significantly different from the values at rest which amounted to 44.14 (SD 2.79) nmol x l(-1). An increase of power output of 30 W above CP-VO2 was accompanied by a significant increase in [H+]b above the resting level (P = 0.03).

  17. Magnetism mediated by a majority of [Fe³⁺ + VO²⁻] complexes in Fe-doped CeO₂ nanoparticles.

    PubMed

    Paidi, V K; Ferreira, N S; Goltz, D; van Lierop, J

    2015-08-26

    We examine the role of Fe(3+) and vacancies (V(O)) on the magnetism of Fe-doped CeO2 nanoparticles. Magnetic nanoparticles of Ce(100-x)Fe(x)O2 (x  =  0, 0.26, 1.82, 2.64, 5.26, 6.91, and 7.22) were prepared by a co-precipitation method, and their structural, compositional and magnetic properties were investigated. The CeO2 nanoparticles had a mixed valance of Ce(4+) and Ce(3+) ions, and doping introduced Fe(3+) ions. The decrease in Ce(3+) and increase in Fe(3+) concentrations indicated the presence of more [Fe(3+) + V(O)(2-)] complexes with Fe loading in the particles. Charge neutralization, Fe(3+) + V(O)(2-) + 2Ce(4+) ↔ 2Ce(3+) + Fe(3+), identified the impact of V(O) on the magnetism, where our results suggest that the Fe-doped CeO2 nanoparticle magnetism is mediated by a majority of [Fe(3+) + V(O)(2-)]-Ce(3+) -[Fe(3+) + V(O)(2-)] complexes.

  18. Preliminary observations in systemic oxygen consumption during targeted temperature management after cardiac arrest.

    PubMed

    Uber, Amy; Grossestreuer, Anne V; Ross, Catherine E; Patel, Parth V; Trehan, Ambica; Donnino, Michael W; Berg, Katherine M

    2018-06-01

    Limited data suggests low oxygen consumption (VO 2 ), driven by mitochondrial injury, is associated with mortality after cardiac arrest. Due to the challenges of measurement in the critically ill, post-arrest metabolism remains poorly characterized. We monitored VO 2 , carbon dioxide production (VCO 2 ) and the respiratory quotient (RQ) in post-arrest patients and explored associations with outcome. Using a gas exchange monitor, we measured continuous VO 2 and VCO 2 in post- arrest patients treated with targeted temperature management. We used area under the curve and medians over time to evaluate the association between VO 2 , VCO 2 , RQ and the VO 2 :lactate ratio with survival. In 17 patients, VO 2 in the first 12 h after return of spontaneous circulation (ROSC) was associated with survival (median in survivors 3.35 mL/kg/min [2.98,3.88] vs. non-survivors 2.61 mL/kg/min [2.21,2.94], p = .039). This did not persist over 24 h. The VO 2 :lactate ratio was associated with survival (median in survivors 1.4 [IQR: 1.1,1.7] vs. non-survivors 0.8 [IQR: 0.6,1.2] p < 0.001). Median RQ was 0.66 (IQR 0.63,0.70) and 71% of RQ measurements were <0.7. Patients with initial RQ < 0.7 had 17% survival versus 64% with initial RQ > 0.7 (p = .131). VCO 2 was not associated with survival. There was a significant association between VO 2 and mortality in the first 12 h after ROSC, but not over 24 h. Lower VO 2: lactate ratio was associated with mortality. A large percentage of patients had RQs below physiologic norms. Further research is needed to explore whether these parameters could have true prognostic value or be a potential treatment target. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. The Effects of Vanadium Pentoxide to Oxalic Acid Ratio and Different Atmospheres on the Formation of VO2 Nanopowders Synthesized via Sol-Gel Method

    NASA Astrophysics Data System (ADS)

    Vostakola, Mohsen Fallah; Yekta, Bijan Eftekhari; Mirkazemi, Seyed Mohammad

    2017-11-01

    Thermochromic VO2 nanopowders were synthesized via the sol-gel method through mixing oxalic acid and vanadium pentoxide in ethanol. We investigated the effect of oxalic acid to vanadium pentoxide ratio on the formation of final product and found that excessive oxalic acid reduced the final product from VO2 to V2O3. Because decreasing the oxalic acid to vanadium pentoxide ratio is a time-consuming process, oxygen was introduced by using a low-porosity alumina tube. The heat treatment was performed inside an electrical tube furnace and in a variety of atmospheres, including pure nitrogen (99.999% purity) and nitrogen containing 5 vol.%, 10 vol.%, and 15 vol.% hydrogen. According to x-ray diffraction (XRD) results, the appropriate atmosphere for synthesizing VO2 nanopowder was the one which contained 10 vol.% hydrogen. In order to decrease the transition temperature in VO2 from 63.5°C to room temperature, W6+ doping was done by adding different amounts of tungstic acid sol to vanadium sol precursor. Differential scanning calorimetry (DSC) results showed that W6+ reduced the transition temperature of VO2 approximately 23°C/wt.%. Lattice straining estimated from XRD results confirmed that VO2 was doped. XRD results at 25°C and 100°C along with DSC results indicated that VO2 was transformed from a low-temperature monoclinic phase to a high-temperature rutile one along this temperature interval.

  20. Sputtering Deposition of Sandwich-Structured V2O5/Metal (V, W)/V2O5 Multilayers for the Preparation of High-Performance Thermally Sensitive VO2 Thin Films with Selectivity of VO2 (B) and VO2 (M) Polymorph.

    PubMed

    Liu, Hengwu; Wan, Dongyun; Ishaq, Ahmad; Chen, Lanli; Guo, Beibei; Shi, Siqi; Luo, Hongjie; Gao, Yanfeng

    2016-03-01

    For specific application to an uncooled infrared detector, VO2 thin films should have a series of characteristics including purposefully chosen polymorphs, accurate stoichiometry, phase stabilization, a high temperature-coefficient of resistance (TCR), and suitable square-resistance. This work reports controllable preparation of high-performance VO2 films via post annealing of a sandwich-structured V2O5/metal (V, W)/V2O5 multilayer precursor, which was deposited by RF magnetron sputtering. This sandwich structure can dynamically regulate oxygen contents and doping element levels in the films, enabling us to achieve accurate regulation of stoichiometry and polymorphs. The precursor films undergo a B to M phase transition depending on the quantity of the metal layers. At the thickness of the metal layer below a limitation, the resulting film after heat treatment was VO2 (B), and above the limitation, the product was VO2 (M). The optical modulation of the VO2 (M) in the near-infrared region can be tuned from 1.2 to 39.8% (ΔT2000 nm). TCR values can range from -1.89 to -4.29%/K and the square-resistances at room temperature (R0) from 69.68 to 12.63 kΩ. The simplicity in phase regulation of the present method and the superior optical and electrical properties of the films may allow its wide applications in thermo-opto-electro sensing devices.

  1. Hydrothermal synthesis of BiVO4/TiO2 composites and their application for degradation of gaseous benzene under visible light irradiation

    NASA Astrophysics Data System (ADS)

    Hu, Yin; Chen, Wei; Fu, Jianping; Ba, Mingwei; Sun, Fuqian; Zhang, Peng; Zou, Jiyong

    2018-04-01

    Benzene is currently recognized as one of the most toxic contaminants. Our previously published study revealed that BiVO4/TiO2 is an excellent photocatalyst toward the degradation of benzene. Herein, BiVO4/TiO2 has been synthesized via a sol-gel method and a facile hydrothermal route by adjusting the precursor hydrolysis rate with the use of different acids (CH3COOH, HNO3 and H2SO4). The influence of these acids on the physicochemical characteristics and photocatalytic performance is discussed in detail. X-ray diffraction and N2 sorption analyses confirm that acid has an important effect on the crystalline composition and BET specific surface area. BiVO4/TiO2 synthesized in CH3COOH has better photocatalytic activity for the degradation of gaseous benzene than that in HNO3 and H2SO4 under visible light irradiation. Results of XPS measurement demonstrate that the hydroxyl group in BiVO4/TiO2-CH3COOH is more abundant than that in BiVO4/TiO2-HNO3 and BiVO4/TiO2-H2SO4. The photocurrent signal is investigated by electrochemical measurement, which indicates that more effective separation of photogenerated carriers occurs in the BiVO4/TiO2/CH3COOH system. It is hoped that our work can offer valuable information on the design of TiO2 composites with enhanced properties.

  2. Formation and evolution of oxygen-vacancy clusters in lead and tin doped silicon

    NASA Astrophysics Data System (ADS)

    Londos, C. A.; Aliprantis, D.; Sgourou, E. N.; Chroneos, A.; Pochet, P.

    2012-06-01

    Infrared spectroscopy (IR) measurements were used to investigate the effect of lead (Pb), tin (Sn), and (Pb, Sn) codoping on electron radiation-induced defects in silicon (Si). The study was mainly focused on oxygen-vacancy (VOn) clusters and in particular their formation and evolution upon annealing. It was determined that Pb causes a larger reduction in the production of the VO defect than Sn. In (Pb, Sn) co-doped Si isochronal anneals revealed that the evolution of VO increases substantially at ˜170 °C. This is attributed to the release of V from the SnV pair. Interestingly, in the corresponding evolution curves of VO in the Sn- and the Pb-doped samples, this inverse annealing stage is also present for the former while it is not present for the latter. This is attributed to the formation of PbV pairs that do not dissociate below 280 °C. The partial capture of V by Sn in co-doped samples is rationalized through the higher compressive local strain around Pb atoms that leads to a retardation of vacancy diffusion. The conversion of VO to the VO2 defect is substantially reduced in the Pb-doped sample. The evolution curves of VO and VO2 clusters in the isovalent doped Si samples hint the production of VO2 from other mechanisms (i.e., besides VO + Oi → VO2). For larger VOn clusters (n = 3,4), the signals are very weak in the Pb-doped sample, whereas for n ≥ 5, they are not present in the spectra. Conversely, bands related with the VO5 and VOnCs defects are present in the spectra of the Sn-doped and (Pb, Sn) codoped Si.

  3. Carbon, oxygen and intrinsic defect interactions in germanium-doped silicon

    NASA Astrophysics Data System (ADS)

    Londos, C. A.; Sgourou, E. N.; Chroneos, A.; Emtsev, V. V.

    2011-10-01

    Production and annealing of oxygen-vacancy (VO) and oxygen-carbon (CiOi, CiOiI) defects in germanium-doped Czochralski-grown silicon (Cz-Si) containing carbon are investigated. All the samples were irradiated with 2 MeV fast electrons. Radiation-produced defects are studied using infrared spectroscopy by monitoring the relevant bands in optical spectra. For the VO defects, it is established that the doping with Ge affects the thermal stability of VO (830 cm-1) defects as well as their fraction converted to VO2 (888 cm-1) defects. In Ge-free samples containing carbon, it was found that carbon impurity atoms do not affect the thermal stability of VO defects, although they affect the fraction of VO defects that is converted to VO2 complexes. Considering the oxygen-carbon complexes, it is established that the annealing of the 862 cm-1 band associated with the CiOi defects is accompanied with the emergence of the 1048 cm-1 band, which has earlier been assigned to the CsO2i center. The evolution of the CiOiI bands is also traced. Ge doping does not seem to affect the thermal stability of the CiOi and CiOiI defects. Density functional theory (DFT) calculations provide insights into the stability of the defect clusters (VO, CiOi, CiOiI) at an atomic level. Both experimental and theoretical results are consistent with the viewpoint that Ge affects the stability of the VO but does not influence the stability of the oxygen-carbon clusters. DFT calculations demonstrate that C attracts both Oi and VO pairs predominately forming next nearest neighbor clusters in contrast to Ge where the interactions with Oi and VO are more energetically favorable at nearest neighbor configurations.

  4. Facile and Low-Temperature Fabrication of Thermochromic Cr2O3/VO2 Smart Coatings: Enhanced Solar Modulation Ability, High Luminous Transmittance and UV-Shielding Function.

    PubMed

    Chang, Tianci; Cao, Xun; Li, Ning; Long, Shiwei; Gao, Xiang; Dedon, Liv R; Sun, Guangyao; Luo, Hongjie; Jin, Ping

    2017-08-09

    In the pursuit of energy efficient materials, vanadium dioxide (VO 2 ) based smart coatings have gained much attention in recent years. For smart window applications, VO 2 thin films should be fabricated at low temperature to reduce the cost in commercial fabrication and solve compatibility problems. Meanwhile, thermochromic performance with high luminous transmittance and solar modulation ability, as well as effective UV shielding function has become the most important developing strategy for ideal smart windows. In this work, facile Cr 2 O 3 /VO 2 bilayer coatings on quartz glasses were designed and fabricated by magnetron sputtering at low temperatures ranging from 250 to 350 °C as compared with typical high growth temperatures (>450 °C). The bottom Cr 2 O 3 layer not only provides a structural template for the growth of VO 2 (R), but also serves as an antireflection layer for improving the luminous transmittance. It was found that the deposition of Cr 2 O 3 layer resulted in a dramatic enhancement of the solar modulation ability (56.4%) and improvement of luminous transmittance (26.4%) when compared to single-layer VO 2 coating. According to optical measurements, the Cr 2 O 3 /VO 2 bilayer structure exhibits excellent optical performances with an enhanced solar modulation ability (ΔT sol = 12.2%) and a high luminous transmittance (T lum,lt = 46.0%), which makes a good balance between ΔT sol and T lum for smart windows applications. As for UV-shielding properties, more than 95.8% UV radiation (250-400 nm) can be blocked out by the Cr 2 O 3 /VO 2 structure. In addition, the visualized energy-efficient effect was modeled by heating a beaker of water using infrared imaging method with/without a Cr 2 O 3 /VO 2 coating glass.

  5. Interactive effects of temperature and hypoxia on heart rate and oxygen consumption of the 3-day old chicken embryo.

    PubMed

    Mortola, Jacopo P; Wills, Kathryn; Trippenbach, Teresa; Al Awam, Khalid

    2010-03-01

    In the chick embryo at day 3, gas exchange occurs by diffusion and oxygen consumption (V(O(2))) does not depend on the cardiovascular convection of O(2). Whether or not this is the case in hypoxia is not known and represents the aim of the study. The heart of chicken embryos at 72 h (stage HH18) was filmed through a window of the eggshell by a camera attached to a microscope. Stroke volume was estimated from the changes in heart silhouette between systole and diastole. V(O(2))was measured by a closed system methodology. In normoxia, a decrease in temperature (T) from 39 to 31 degrees C had parallel depressant effects on V(O(2))and HR. At 39 degrees C, a progressive decrease in O(2) lowered V(O(2)); HR was maintained until the O(2) threshold of approximately 15%. In severe hypoxia (4% O(2)) V(O(2))and HR were, respectively, approximately 12% and approximately 62% of normoxia. At 32 degrees C the hypoxic threshold for HR was significantly lower. During constant hypoxia (7% O(2)) V(O(2))did not respond to T, while the HR response was preserved. Stroke volume changed little with changes in T or O(2), except at 6 and 4% O(2), when it decreased by approximately 20 and 30%. In embryos growth-retarded because of incubation in chronic hypoxia, V(O(2))and HR responses to T and hypoxia were similar to those of normal embryos. We conclude that in the early embryo during hypoxia cardiovascular O(2) convection is not responsible for the drop in V(O(2)). The generalised hypometabolic response, in combination with the extremely small cardiac V(O(2)), probably explains the minor effects of hypoxia on cardiac activity. Copyright 2009 Elsevier Inc. All rights reserved.

  6. Coordination chemistry and insulin-enhancing behavior of vanadium complexes with maltol C6H6O3 structural isomers.

    PubMed

    Saatchi, Katayoun; Thompson, Katherine H; Patrick, Brian O; Pink, Maren; Yuen, Violet G; McNeill, John H; Orvig, Chris

    2005-04-18

    Syntheses of vanadium complexes using the naturally occurring ligands isomaltol (Hima) and allomaltol (Hama), as well as a newly synthesized, potentially tetradentate diaminodipyrone [H(2)(en(ama)(2)], are reported. Complete characterization of the resulting compounds [trans-VO(ima)(2)(H(2)O), VO(ama)(2), V(ima)(3), V(ama)(3) and VO(en(ama)(2))], including X-ray crystallography analyses for trans-VO(ima)(2)(H(2)O) and V(ima)(3), are presented herein. Potentiometric titrations (25 degrees C, I = 0.16 M NaCl) were used to measure stability constants in the V(IV)-Hima system; these data were compared to previous data collected on the V(IV)-L (L = Hma, Hama) systems. The in vivo efficacy of these compounds to lower the blood glucose levels of STZ-diabetic rats was tested; all but VO(en(ama)(2)) produced significant decreases in plasma glucose levels. The results were compared to those of the benchmark compound BMOV [VO(ma)(2), bis(maltolato)oxovanadium(IV)], a known insulin-enhancing agent.

  7. Estimation of oxygen consumption during cycling and rowing.

    PubMed

    Baig, Dur-e-Zehra; Savkin, Andrey V; Celler, Branko G

    2012-01-01

    The aim of this paper is to develop estimator that can predict oxygen consumption (V(O2)) during cycling and rowing exercises, by using non-invasive and easily measurable quantities such as heart rate (HR), respiratory rate (RespR) and frequency of exercising activity. The frequency of exercise is quantified as a universal measure of exercise intensity and is known as Exercise Rate (ER). This ER is responsible for deviation in V(O2) (ΔV(O2)), HR (ΔHR), and RespR (ΔRespR) from their respective baseline measurements during exercise. Therefore, ΔV(O2) can be estimated from Δ, ΔRespR and ER. The resting measured of V(O2) is referred as V(O(2rest)); this is computed from the physical fitness of an individual. The Hammerstein model is adopted for the estimation of ΔV(O2). Results in this study demonstrate that the developed estimators for each type of exercise are capable of estimating V(O2) by adding up V(O(2rest)) and ΔV(O2) at various intensities during cycling and rowing.

  8. Unraveling Metal-insulator Transition Mechanism of VO2 Triggered by Tungsten Doping

    PubMed Central

    Tan, Xiaogang; Yao, Tao; Long, Ran; Sun, Zhihu; Feng, Yajuan; Cheng, Hao; Yuan, Xun; Zhang, Wenqing; Liu, Qinghua; Wu, Changzheng; Xie, Yi; Wei, Shiqiang

    2012-01-01

    Understanding the mechanism of W-doping induced reduction of critical temperature (TC) for VO2 metal-insulator transition (MIT) is crucial for both fundamental study and technological application. Here, using synchrotron radiation X-ray absorption spectroscopy combined with first-principles calculations, we unveil the atomic structure evolutions of W dopant and its role in tailoring the TC of VO2 MIT. We find that the local structure around W atom is intrinsically symmetric with a tetragonal-like structure, exhibiting a concentration-dependent evolution involving the initial distortion, further repulsion, and final stabilization due to the strong interaction between doped W atoms and VO2 lattices across the MIT. These results directly give the experimental evidence that the symmetric W core drives the detwisting of the nearby asymmetric monoclinic VO2 lattice to form rutile-like VO2 nuclei, and the propagations of these W-encampassed nuclei through the matrix lower the thermal energy barrier for phase transition. PMID:22737402

  9. Solution-processed phase-change VO(2) metamaterials from colloidal vanadium oxide (VO(x)) nanocrystals.

    PubMed

    Paik, Taejong; Hong, Sung-Hoon; Gaulding, E Ashley; Caglayan, Humeyra; Gordon, Thomas R; Engheta, Nader; Kagan, Cherie R; Murray, Christopher B

    2014-01-28

    We demonstrate thermally switchable VO2 metamaterials fabricated using solution-processable colloidal nanocrystals (NCs). Vanadium oxide (VOx) NCs are synthesized through a nonhydrolytic reaction and deposited from stable colloidal dispersions to form NC thin films. Rapid thermal annealing transforms the VOx NC thin films into monoclinic, nanocrystalline VO2 thin films that show a sharp, reversible metal-insulator phase transition. Introduction of precise concentrations of tungsten dopings into the colloidal VOx NCs enables the still sharp phase transition of the VO2 thin films to be tuned to lower temperatures as the doping level increases. We fabricate "smart", differentially doped, multilayered VO2 films to program the phase and therefore the metal-insulator behavior of constituent vertically structured layers with temperature. With increasing temperature, we tailored the optical response of multilayered films in the near-IR and IR regions from that of a strong light absorber, in a metal-insulator structure, to that of a Drude-like reflector, characteristic of a pure metallic structure. We demonstrate that nanocrystal-based nanoimprinting can be employed to pattern multilayered subwavelength nanostructures, such as three-dimensional VO2 nanopillar arrays, that exhibit plasmonic dipolar responses tunable with a temperature change.

  10. Mineral transformations during the dissolution of uranium ore minerals by dissimilatory metal-reducing bacteria

    NASA Astrophysics Data System (ADS)

    Glasauer, S.; Weidler, P.; Fakra, S.; Tyliszczak, T.; Shuh, D.

    2011-12-01

    Carnotite minerals [X2(UO2)2(VO4)2]; X = K, Ca, Ba, Mn, Na, Cu or Pb] form the major ore of uranium in the Colorado Plateau. These deposits are highly oxidized and contain U(VI) and V(IV). The biotransformation of U(VI) bound in carnotite by bacteria during dissimilatory metal reduction presents a complex puzzle in mineral chemistry. Both U(VI) and V(V) can be respired by metal reducing bacteria, and the mineral structure can change depending on the associated counterion. We incubated anaerobic cultures of S. putrefaciens CN32 with natural carnotite minerals from southeastern Utah in a nutrient-limited defined medium. Strain CN32 is a gram negative bacterium and a terrestrial isolate from New Mexico. The mineral and metal transformations were compared to a system that contained similar concentrations of soluble U(VI) and V(V). Electron (SEM, TEM) microscopies and x-ray spectromicroscopy (STXM) were used in conjunction with XRD to track mineral changes, and bacterial survival was monitored throughout the incubations. Slow rates of metal reduction over 10 months for the treatment with carnotite minerals revealed distinct biotic and abiotic processes, providing insight on mineral transformation and bacteria-metal interactions. The bacteria existed as small flocs or individual cells attached to the mineral phase, but did not adsorb soluble U or V, and accumulated very little of the biominerals. Reduction of mineral V(V) necessarily led to a dismantling of the carnotite structure. Bioreduction of V(V) by CN32 contributed small but profound changes to the mineral system, resulting in new minerals. Abiotic cation exchange within the carnotite group minerals induced the rearrangement of the mineral structures, leading to further mineral transformation. In contrast, bacteria survival was poor for treatments with soluble U(VI) and V(V), although both metals were reduced completely and formed solid UO2 and VO2; we also detected V(III). For these treatments, the bacteria formed extensive biofilms or flocs that contained U and V in the exopolymer, but excluded these metals from the bacteria. This suggests a specific mechanism to inhibit metal sorption to cell wall components. The example illustrates the interplay between bacteria and minerals under conditions that model oligotrophic survival, and provides insight on U mobilization from common uranium ore minerals.

  11. Pulmonary Oxygen Uptake Kinetics During Exercise in Subclinical Hypothyroidism

    PubMed Central

    Coelho, Emerson Filipino; de Lima, Jorge Roberto Perrout; Laterza, Mateus Camaroti; Barral, Marselha Marques; Teixeira, Patrícia de Fátima dos Santos; Vaisman, Mário

    2014-01-01

    Background: Patients with subclinical hypothyroidism (SCH) have lower exercise tolerance, but the impact on oxygen uptake (VO2) kinetics is unknown. This study evaluated VO2 kinetics during and after a constant load submaximal exercise in SCH. Methods: The study included 19 women with SCH (thyrotropin (TSH)=6.87±2.88 μIU/mL, free thyroxine (fT4)=0.97±0.15 ng/dL) and 19 controls (TSH=2.29±0.86 μIU/mL, T4=0.99±0.11 ng/dL) aged between 20 and 55 years. Ergospirometry exercise testing was performed for six minutes with a constant load of 50 W, followed by six minutes of passive recovery. The VO2 kinetics was quantified by the mean response time (MRT), which is the exponential time constant and approximates the time needed to reach 63% of change in VO2 (ΔVO2). The O2 deficit—energy supplied by anaerobic metabolism at the onset of exercise—and O2 debit—extra energy demand during the recovery period—were calculated by the formula MRT×ΔVO2. Values are mean±standard deviation. Results: In the rest-exercise transition, patients with SCH showed slower VO2 kinetics (MRT=47±8 sec vs. 40±6 sec, p=0.004) and a higher oxygen deficit (580±102 mL vs. 477±95 mL, p=0.003) than controls respectively. In the exercise-recovery transition, patients with SCH also showed slower VO2 kinetics (MRT=54±6 sec vs. 44±6 sec, p=0.001) and a higher oxygen debit (679±105 mL vs. 572±104 mL, p=0.003). The VO2 kinetics showed a significant correlation with TSH (p<0.05). Conclusions: This study demonstrates that women with SCH have the slowest VO2 kinetics in the onset and recovery of a constant-load submaximal exercise and highlights that this impairment is already manifest in the early stage of the disease. PMID:24512502

  12. Pulmonary oxygen uptake kinetics during exercise in subclinical hypothyroidism.

    PubMed

    Werneck, Francisco Zacaron; Coelho, Emerson Filipino; de Lima, Jorge Roberto Perrout; Laterza, Mateus Camaroti; Barral, Marselha Marques; Teixeira, Patrícia de Fátima Dos Santos; Vaisman, Mário

    2014-06-01

    Patients with subclinical hypothyroidism (SCH) have lower exercise tolerance, but the impact on oxygen uptake (VO2) kinetics is unknown. This study evaluated VO2 kinetics during and after a constant load submaximal exercise in SCH. The study included 19 women with SCH (thyrotropin (TSH)=6.87±2.88 μIU/mL, free thyroxine (fT4)=0.97±0.15 ng/dL) and 19 controls (TSH=2.29±0.86 μIU/mL, T4=0.99±0.11 ng/dL) aged between 20 and 55 years. Ergospirometry exercise testing was performed for six minutes with a constant load of 50 W, followed by six minutes of passive recovery. The VO2 kinetics was quantified by the mean response time (MRT), which is the exponential time constant and approximates the time needed to reach 63% of change in VO2 (ΔVO2). The O2 deficit-energy supplied by anaerobic metabolism at the onset of exercise-and O2 debit-extra energy demand during the recovery period-were calculated by the formula MRT×ΔVO2. Values are mean±standard deviation. In the rest-exercise transition, patients with SCH showed slower VO2 kinetics (MRT=47±8 sec vs. 40±6 sec, p=0.004) and a higher oxygen deficit (580±102 mL vs. 477±95 mL, p=0.003) than controls respectively. In the exercise-recovery transition, patients with SCH also showed slower VO2 kinetics (MRT=54±6 sec vs. 44±6 sec, p=0.001) and a higher oxygen debit (679±105 mL vs. 572±104 mL, p=0.003). The VO2 kinetics showed a significant correlation with TSH (p<0.05). This study demonstrates that women with SCH have the slowest VO2 kinetics in the onset and recovery of a constant-load submaximal exercise and highlights that this impairment is already manifest in the early stage of the disease.

  13. Tuning of thermally induced first-order semiconductor-to-metal transition in pulsed laser deposited VO2 epitaxial thin films

    NASA Astrophysics Data System (ADS)

    Behera, Makhes K.; Pradhan, Dhiren K.; Pradhan, Sangram K.; Pradhan, Aswini K.

    2017-12-01

    Vanadium oxide (VO2) thin films have drawn significant research and development interest in recent years because of their intriguing physical origin and wide range of functionalities useful for many potential applications, including infrared imaging, smart windows, and energy and information technologies. However, the growth of highly epitaxial films of VO2, with a sharp and distinct controllable transition, has remained a challenge. Here, we report the structural and electronic properties of high quality and reproducible epitaxial thin films of VO2, grown on c-axis oriented sapphire substrates using pulsed laser deposition at different deposition pressures and temperatures, followed by various annealing schedules. Our results demonstrate that the annealing of epitaxial VO2 films significantly enhances the Semiconductor to Metal Transition (SMT) to that of bulk VO2 transition. The effect of oxygen partial pressure during the growth of VO2 films creates a significant modulation of the SMT from around room temperature to as high as the theoretical value of 68 °C. We obtained a bulk order transition ≥104 while reducing the transition temperature close to 60 °C, which is comparatively less than the theoretical value of 68 °C, demonstrating a clear and drastic improvement in the SMT switching characteristics. The results reported here will open the door to fundamental studies of VO2, along with tuning of the transition temperatures for potential applications for multifunctional devices.

  14. Protective effect of treatment with black cumin oil on spatial cognitive functions of rats that suffered global cerebrovascular hypoperfusion.

    PubMed

    Azzubaidi, Marwan Saad; Saxena, Anil Kumar; Talib, Norlelawati Abi; Ahmed, Qamar Uddin; Dogarai, Bashar Bello

    2012-01-01

    The fixed oil of black cumin seeds, Nigella sativa L. (NSO), has shown considerable antioxidant and anti-inflammatory activities. Chronic cerebral hypoperfusion has been linked to neurodegenerative disorders including Alzheimer's disease (AD) and its subsequent cognitive impairment in which oxidative stress and neuroinflammation are the principal culprits. Cerebrovascular hypoperfusion was experimentally achieved by bilateral common carotid arteries occlusion (2VO) in rats. Morris water maze (MWM) test was employed to assess the effects of NSO on spatial cognitive function before and after 2VO intervention. Rats were divided into long-term memory (LTM) and short-term memory (STM) groups, each was further subdivided into 3 subgroups: sham control, untreated 2VO and NSO treated 2VO group. All subgroups were tested with MWM at the tenth postoperative week. Working memory test results for both sham control and NSO treated groups showed significantly lower escape latency time and total distance travelled than untreated 2VO group. Similarly, LTM and STM MWM tests for sham control and NSO treated groups revealed significantly better maze test performance as compared to untreated 2VO group. Sham control and NSO treated 2VO groups demonstrated superior probe memory test performance as compared to untreated 2VO group. The fixed oil of Nigella sativa seeds has demonstrated noticeable spatial cognitive preservation in rats challenged with chronic cerebral hypoperfusion which indicates a promising prospective neuroprotective effect.

  15. Isolating Component Processes of Posterror Slowing with the Psychological Refractory Period Paradigm

    ERIC Educational Resources Information Center

    Steinhauser, Marco; Ernst, Benjamin; Ibald, Kevin W.

    2017-01-01

    Posterror slowing (PES) refers to an increased response time following errors. While PES has traditionally been attributed to control adjustments, recent evidence suggested that PES reflects interference. The present study investigated the hypothesis that control and interference represent 2 components of PES that differ with respect to their time…

  16. Effect of Pharmacologically-Induced Hypovolemia on Aerobic Capacity

    NASA Technical Reports Server (NTRS)

    Everett, Meghan E.; Lee, S. M. C.; Platts, S. H.

    2009-01-01

    Decreased peak oxygen consumption (VO2pk) and an elevated exercise heart rate (HR) response are associated with a reduction in plasma volume (PV) after space flight and bed rest, a space flight analog. Reduced VO2pk and submaximal exercise tolerance would negatively impact an astronaut s ability to perform near maximal work that would be required in the event of an emergency. We previously have administered IV furosemide followed by a low salt diet to model PV loss and orthostatic intolerance observed after spaceflight. Purpose: To determine whether a pharmacologically-induced reduction in PV results in decreased VO2pk and elevated exercise HR response. Methods: Six subjects (5M, 1F) performed two graded peak cycle tests (work rate increased by 35 or 50 W every 3 min), once while normovolemic and once while hypovolemic. HR and expired respiratory gases were continuously measured. To induce hypovolemia, subjects were administered a single dose of IV furosemide (0.5 mg.kg-1) 30 hr before exercise testing and then consumed a low-salt diet (10 mEq.d(sup -1)). PV was measured using carbon monoxide rebreathing. Exercise HR and VO2 responses were quantified as the area under the curve (AUC) calculated over each quartile of the peak test, based on test time in the hypovolemia condition. Paired t-tests were used to test for differences in PV, VO2pk, and peak HR between conditions. Repeated-measures ANOVAs were used to test for differences in AUC between conditions. Results: PV (3.32+/-0.12 vs. 2.77+/-0.16 L, p<0.05) and VO2pk (3.30+/-0.67 vs. 2.90+/-0.57 L.min(sup -1), p<0.05) were lower during hypovolemia than during normovolemia, but peak HR was not different (187+/-5 vs. 187+/-5 bpm). The AUC for VO2 and HR was different (p<0.05) between conditions only in the highest quartile: HR was 4% higher and VO2 was 5% lower during the hypovolemia condition. Conclusion: The mean difference in VO2pk (-12%) between normovolemia and hypovolemia was similar to the mean difference in PV (-17%). Similar decreases in PV and VO2pk have been observed following short duration space flight, suggesting that pharmacologically-induced PV loss can be used to model microgravity-induced reductions in VO2pk.

  17. Brain potentials predict substance abuse treatment completion in a prison sample.

    PubMed

    Fink, Brandi C; Steele, Vaughn R; Maurer, Michael J; Fede, Samantha J; Calhoun, Vince D; Kiehl, Kent A

    2016-08-01

    National estimates suggest that up to 80% of prison inmates meet diagnostic criteria for a substance use disorder. Because more substance abuse treatment while incarcerated is associated with better post-release outcomes, including a reduced risk of accidental overdose death, the stakes are high in developing novel predictors of substance abuse treatment completion in inmate populations. Using electroencephalography (EEG), this study investigated stimulus-locked ERP components elicited by distractor stimuli in three tasks (VO-Distinct, VO-Repeated, Go/NoGo) as a predictor of treatment discontinuation in a sample of male and female prison inmates. We predicted that those who discontinued treatment early would exhibit a less positive P3a amplitude elicited by distractor stimuli. Our predictions regarding ERP components were partially supported. Those who discontinued treatment early exhibited a less positive P3a amplitude and a less positive PC4 in the VO-D task. In the VO-R task, however, those who discontinued treatment early exhibited a more negative N200 amplitude rather than the hypothesized less positive P3a amplitude. The discontinuation group also displayed less positive PC4 amplitude. Surprisingly, there were no time-domain or principle component differences among the groups in the Go/NoGo task. Support Vector Machine (SVM) models of the three tasks accurately classified individuals who discontinued treatment with the best model accurately classifying 75% of inmates. PCA techniques were more sensitive in differentiating groups than the classic time-domain windowed approach. Our pattern of findings are consistent with the context-updating theory of P300 and may help identify subtypes of ultrahigh-risk substance abusers who need specialized treatment programs.

  18. Effect of simulated weightlessness on exercise-induced anaerobic threshold

    NASA Technical Reports Server (NTRS)

    Convertino, V. A.; Karst, G. M.; Kirby, C. R.; Goldwater, D. J.

    1986-01-01

    The effect of simulated weightlessness, induced by ten days of continuous bedrest (BR) in the -6 deg head-down position, on the exercise-induced anaerobic threshold (AT) was determined by comparing specific ventilatory and gas-exchange measurements during an incremental ergometer test performed before and after BR. The primary index for determining the exercise-induced AT values of each subject was visual identification of the workrate or oxygen uptake (VO2) at which the ratio of the expired minute ventilation volume (VE) to VO2 exhibited a systematic increase without a concomitant increase in the VE/VCO2 value. Following BR, the mean VO2max of the subjects decreased by 7.0 percent, and the AT decreased from a mean of 1.26 L/min VO2 before BR to 0.95 L/min VO2 after BR. The decrease in AT was manifested by a decrease in both absolute and relative workrates. The change in AT correlated significantly with the change in plasma volume but not with the change in VO2max. The results suggest that the reduction in AT cannot be completely explained by the reduction in VO2, and that the AT decrease is associated with the reduction in intravascular fluid volume.

  19. Thermal aging effect of vanadyl acetylacetonate precursor for deposition of VO{sub 2} thin films with thermochromic properties

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Jung-Hoon; Nam, Sang-Hun; Kim, Donguk

    Highlights: • 7 day aged VO(acac){sub 2} sol shows enhanced adhesivity on the SiO{sub 2} compared with non-aged sol. • The aging process has significantly affected the morphologies of VO{sub 2} films. • From the FT-IR spectra, thermal aging process provides the deformation of precursor. • The metal insulator transition (MIT) efficiency (ΔT{sub at2000} {sub nm}) reached a maximum value of 51% at 7 day aging. • Thermal aging process could shorten the aging time of sol solution. - Abstract: Thermochromic properties of vanadium dioxide (VO{sub 2}) have been studied extensively due to their IR reflection applications in energy smartmore » windows. In this paper, we studied the optical switching property of VO{sub 2} thin film, depending on the thermal aging time of the vanadyl acetylacetonate (VO(acac){sub 2}) precursor. We found the alteration of the IR spectra of the precursor by tuning the aging time as well as heat treatments of the precursor. An aging effect of vanadium precursor directly affects the morphologies, optical switching property and crystallinity of VO{sub 2} films. The optimum condition was achieved at the 7 day aging time with metal insulator transition (MIT) efficiency of 50%.« less

  20. Prediction of Maximal Aerobic Capacity in Severely Burned Children

    PubMed Central

    Porro, Laura; Rivero, Haidy G.; Gonzalez, Dante; Tan, Alai; Herndon, David N.; Suman, Oscar E.

    2011-01-01

    Introduction Maximal oxygen uptake (VO2 peak) is an indicator of cardiorespiratory fitness, but requires expensive equipment and a relatively high technical skill level. Purpose The aim of this study is to provide a formula for estimating VO2 peak in burned children, using information obtained without expensive equipment. Methods Children, with ≥40% total surface area burned (TBSA), underwent a modified Bruce treadmill test to asses VO2 peak at 6 months after injury. We recorded gender, age, %TBSA, %3rd degree burn, height, weight, treadmill time, maximal speed, maximal grade, and peak heart rate, and applied McHenry’s select algorithm to extract important independent variables and Robust multiple regression to establish prediction equations. Results 42 children; 7 to 17 years old were tested. Robust multiple regression model provided the equation: VO2=10.33 – 0.62 *Age (years) + 1.88 * Treadmill Time (min) + 2.3 (gender; Females = 0, Males = 1). The correlation between measured and estimated VO2 peak was R=0.80. We then validated the equation with a group of 33 burned children, which yielded a correlation between measured and estimated VO2 peak of R=0.79. Conclusions Using only a treadmill and easily gathered information, VO2 peak can be estimated in children with burns. PMID:21316155

  1. Effect of Toe Clips During Bicycle Ergometry on VO2 max.

    ERIC Educational Resources Information Center

    Moffat, Roger S.; Sparling, Phillip B.

    1985-01-01

    Eight men participated in three randomized maximal oxygen uptake tests to investigate the hypothesis that the use of toe clips on bicycle ergometers produced a higher VO2 max. No significant difference in mean VO2 max or performance time was observed. (Author/MT)

  2. Individual Variability in Aerobic Fitness Adaptations to 70-d of Bed Rest and Exercise Training

    NASA Technical Reports Server (NTRS)

    Downs, Meghan; Buxton, Roxanne; Goetchius, Elizabeth; DeWitt, John; Ploutz-Snyder, Lori

    2016-01-01

    Change in maximal aerobic capacity (VO2pk) in response to exercise training and disuse is highly variable among individuals. Factors that could contribute to the observed variability (lean mass, daily activity, diet, sleep, stress) are not routinely controlled in studies. The NASA bed rest (BR) studies use a highly controlled hospital based model as an analog of spaceflight. In this study, diet, hydration, physical activity and light/dark cycles were precisely controlled and provided the opportunity to investigate individual variability. PURPOSE. Evaluate the contribution of exercise intensity and lean mass on change in VO2pk during 70-d of BR or BR + exercise. METHODS. Subjects completed 70-d of BR alone (CON, N=9) or BR + exercise (EX, N=17). The exercise prescription included 6 d/wk of aerobic exercise at 70 - 100% of max and 3 d/wk of lower body resistance exercise. Subjects were monitored 24 hr/d. VO2pk and lean mass (iDXA) were measured pre and post BR. ANOVA was used to evaluate changes in VO2pk pre to post BR. Subjects were retrospectively divided into high and low responders based on change in VO2pk (CON > 20% loss, n=5; EX >10% loss, n=4, or 5% gain, n=4) to further understand individual variability. RESULTS. VO2pk decreased from pre to post BR in CON (P<0.05) and was maintained in EX; however, significant individual variability was observed (CON: -22%, range: -39% to -.5%; EX: -1.8%, range: -16% to 12.6%). The overlap in ranges between groups included 3 CON who experienced smaller reduction in VO2pk (<16%) than the worst responding EX subjects. Individual variability was maintained when VO2pk was normalized to lean mass (range, CON: -33.7% to -5.7%; EX: -15.8% to 11%), and the overlap included 5 CON with smaller reductions in VO2pk than the worst responding EX subjects. High responders to disuse also lost the most lean mass; however, this relationship was not maintained in EX (i.e. the largest gains/losses in lean mass were observed in both high and low responders). Change in VO2pk was not related to exercise intensity. CONCLUSION. Change in VO2pk in response to disuse and exercise was highly variable among individuals, even in this tightly controlled study. Loss in lean mass accounts for a significant degree of variability in the CON; however, training induced gains in VO2pk appear unrelated to lean mass or exercise intensity.

  3. Strain Effects in Epitaxial VO2 Thin Films on Columnar Buffer-Layer TiO2/Al2O3 Virtual Substrates.

    PubMed

    Breckenfeld, Eric; Kim, Heungsoo; Burgess, Katherine; Charipar, Nicholas; Cheng, Shu-Fan; Stroud, Rhonda; Piqué, Alberto

    2017-01-18

    Epitaxial VO 2 /TiO 2 thin film heterostructures were grown on (100) (m-cut) Al 2 O 3 substrates via pulsed laser deposition. We have demonstrated the ability to reduce the semiconductor-metal transition (SMT) temperature of VO 2 to ∼44 °C while retaining a 4 order of magnitude SMT using the TiO 2 buffer layer. A combination of electrical transport and X-ray diffraction reciprocal space mapping studies help examine the specific strain states of VO 2 /TiO 2 /Al 2 O 3 heterostructures as a function of TiO 2 film growth temperatures. Atomic force microscopy and transmission electron microscopy analyses show that the columnar microstructure present in TiO 2 buffer films is responsible for the partially strained VO 2 film behavior and subsequently favorable transport characteristics with a lower SMT temperature. Such findings are of crucial importance for both the technological implementation of the VO 2 system, where reduction of its SMT temperature is widely sought, as well as the broader complex oxide community, where greater understanding of the evolution of microstructure, strain, and functional properties is a high priority.

  4. Peak oxygen uptake in Paralympic sitting sports: A systematic literature review, meta- and pooled-data analysis.

    PubMed

    Baumgart, Julia Kathrin; Brurok, Berit; Sandbakk, Øyvind

    2018-01-01

    Peak oxygen uptake (VO2peak) in Paralympic sitting sports athletes represents their maximal ability to deliver energy aerobically in an upper-body mode, with values being influenced by sex, disability-related physiological limitations, sport-specific demands, training status and how they are tested. To identify VO2peak values in Paralympic sitting sports, examine between-sports differences and within-sports variations in VO2peak and determine the influence of sex, age, body-mass, disability and test-mode on VO2peak. Systematic literature review and meta-analysis. PubMed, CINAHL, SPORTDiscusTM and EMBASE were systematically searched in October 2016 using relevant medical subject headings, keywords and a Boolean. Studies that assessed VO2peak values in sitting sports athletes with a disability in a laboratory setting were included. Data was extracted and pooled in the different sports disciplines, weighted by the Dersimonian and Laird random effects approach. Quality of the included studies was assessed with a modified version of the Downs and Black checklist by two independent reviewers. Meta-regression and pooled-data multiple regression analyses were performed to assess the influence of sex, age, body-mass, disability, test mode and study quality on VO2peak. Of 6542 retrieved articles, 57 studies reporting VO2peak values in 14 different sitting sports were included in this review. VO2peak values from 771 athletes were used in the data analysis, of which 30% participated in wheelchair basketball, 27% in wheelchair racing, 15% in wheelchair rugby and the remaining 28% in the 11 other disciplines. Fifty-six percent of the athletes had a spinal cord injury and 87% were men. Sports-discipline-averaged VO2peak values ranged from 2.9 L∙min-1 and 45.6 mL∙kg-1∙min-1 in Nordic sit skiing to 1.4 L∙min-1 and 17.3 mL∙kg-1∙min-1 in shooting and 1.3 L∙min-1 and 18.9 mL∙kg-1∙min-1 in wheelchair rugby. Large within-sports variation was found in sports with few included studies and corresponding low sample sizes. The meta-regression and pooled-data multiple regression analyses showed that being a man, having an amputation, not being tetraplegic, testing in a wheelchair ergometer and treadmill mode, were found to be favorable for high absolute and body-mass normalized VO2peak values. Furthermore, high body mass was favourable for high absolute VO2peak values and low body mass for high body-mass normalized VO2peak values. The highest VO2peak values were found in Nordic sit skiing, an endurance sport with continuously high physical efforts, and the lowest values in shooting, a sport with low levels of displacement, and in wheelchair rugby where mainly athletes with tetraplegia compete. However, VO2peak values need to be interpreted carefully in sports-disciplines with few included studies and large within-sports variation. Future studies should include detailed information on training status, sex, age, test mode, as well as the type and extent of disability in order to more precisely evaluate the effect of these factors on VO2peak.

  5. Peak oxygen uptake in Paralympic sitting sports: A systematic literature review, meta- and pooled-data analysis

    PubMed Central

    Brurok, Berit; Sandbakk, Øyvind

    2018-01-01

    Background Peak oxygen uptake (VO2peak) in Paralympic sitting sports athletes represents their maximal ability to deliver energy aerobically in an upper-body mode, with values being influenced by sex, disability-related physiological limitations, sport-specific demands, training status and how they are tested. Objectives To identify VO2peak values in Paralympic sitting sports, examine between-sports differences and within-sports variations in VO2peak and determine the influence of sex, age, body-mass, disability and test-mode on VO2peak. Design Systematic literature review and meta-analysis. Data sources PubMed, CINAHL, SPORTDiscusTM and EMBASE were systematically searched in October 2016 using relevant medical subject headings, keywords and a Boolean. Eligibility criteria Studies that assessed VO2peak values in sitting sports athletes with a disability in a laboratory setting were included. Data synthesis Data was extracted and pooled in the different sports disciplines, weighted by the Dersimonian and Laird random effects approach. Quality of the included studies was assessed with a modified version of the Downs and Black checklist by two independent reviewers. Meta-regression and pooled-data multiple regression analyses were performed to assess the influence of sex, age, body-mass, disability, test mode and study quality on VO2peak. Results Of 6542 retrieved articles, 57 studies reporting VO2peak values in 14 different sitting sports were included in this review. VO2peak values from 771 athletes were used in the data analysis, of which 30% participated in wheelchair basketball, 27% in wheelchair racing, 15% in wheelchair rugby and the remaining 28% in the 11 other disciplines. Fifty-six percent of the athletes had a spinal cord injury and 87% were men. Sports-discipline-averaged VO2peak values ranged from 2.9 L∙min-1 and 45.6 mL∙kg-1∙min-1 in Nordic sit skiing to 1.4 L∙min-1 and 17.3 mL∙kg-1∙min-1 in shooting and 1.3 L∙min-1 and 18.9 mL∙kg-1∙min-1 in wheelchair rugby. Large within-sports variation was found in sports with few included studies and corresponding low sample sizes. The meta-regression and pooled-data multiple regression analyses showed that being a man, having an amputation, not being tetraplegic, testing in a wheelchair ergometer and treadmill mode, were found to be favorable for high absolute and body-mass normalized VO2peak values. Furthermore, high body mass was favourable for high absolute VO2peak values and low body mass for high body-mass normalized VO2peak values. Conclusion The highest VO2peak values were found in Nordic sit skiing, an endurance sport with continuously high physical efforts, and the lowest values in shooting, a sport with low levels of displacement, and in wheelchair rugby where mainly athletes with tetraplegia compete. However, VO2peak values need to be interpreted carefully in sports-disciplines with few included studies and large within-sports variation. Future studies should include detailed information on training status, sex, age, test mode, as well as the type and extent of disability in order to more precisely evaluate the effect of these factors on VO2peak. PMID:29474386

  6. Concentration Dependence of VO2+ Crossover of Nafion for Vanadium Redox Flow Batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lawton, Jamie; Jones, Amanda; Zawodzinski, Thomas A

    2013-01-01

    The VO2+ crossover, or permeability, through Nafion in a vanadium redox flow battery (VRFB) was monitored as a function of sulfuric acid concentration and VO2+ concentration. A vanadium rich solution was flowed on one side of the membrane through a flow field while symmetrically on the other side a blank or vanadium deficit solution was flowed. The blank solution was flowed through an electron paramagnetic resonance (EPR) cavity and the VO2+ concentration was determined from the intensity of the EPR signal. Concentration values were fit using a solution of Fick s law that allows for the effect of concentration changemore » on the vanadium rich side. The fits resulted in permeability values of VO2+ ions across the membrane. Viscosity measurements of many VO2+ and H2SO4 solutions were made at 30 60 C. These viscosity values were then used to determine the effect of the viscosity of the flowing solution on the permeability of the ion. 2013 The Electrochemical Society. [DOI: 10.1149/2.004306jes] All rights reserved.« less

  7. Synthesis, crystal structure and optical properties of BiMgVO 5

    NASA Astrophysics Data System (ADS)

    Benmokhtar, S.; El Jazouli, A.; Chaminade, J. P.; Gravereau, P.; Guillen, F.; de Waal, D.

    2004-11-01

    The new vanadate BiMgVO 5 has been prepared and its structure has been determined by single crystal X-ray diffraction: space group P21/n, a=7.542(6) Å, b=11.615(5) Å, c=5.305(3) Å, β=107.38(5)°, wR2=0.0447, R=0.0255. The structure consists of [Mg 2O 10] and [Bi 2O 10] dimers sharing their corners with [VO 4] tetrahedra. The ranges of bond lengths are 2.129-2.814 Å for Bi-O; 2.035-2.167 Å for Mg-O and 1.684-1.745 Å for V-O. V-O bond lengths determined from Raman band wavenumbers are between 1.679 and 1.747 Å. An emission band overlapping the entire visible region with a maximum around 650 nm is observed.

  8. Selective scanning tunneling microscope light emission from rutile phase of VO2.

    PubMed

    Sakai, Joe; Kuwahara, Masashi; Hotsuki, Masaki; Katano, Satoshi; Uehara, Yoichi

    2016-09-28

    We observed scanning tunneling microscope light emission (STM-LE) induced by a tunneling current at the gap between an Ag tip and a VO2 thin film, in parallel to scanning tunneling spectroscopy (STS) profiles. The 34 nm thick VO2 film grown on a rutile TiO2 (0 0 1) substrate consisted of both rutile (R)- and monoclinic (M)-structure phases of a few 10 nm-sized domains at room temperature. We found that STM-LE with a certain photon energy of 2.0 eV occurs selectively from R-phase domains of VO2, while no STM-LE was observed from M-phase. The mechanism of STM-LE from R-phase VO2 was determined to be an interband transition process rather than inverse photoemission or inelastic tunneling processes.

  9. Effects of electrical stimulation on VO2 kinetics and delta efficiency in healthy young men

    PubMed Central

    Perez, M; Lucia, A; Santalla, A; Chicharro, J

    2003-01-01

    Objective: To determine the effects of electrical stimulation (ES) on oxygen uptake (VO2) kinetics and delta efficiency (DE) during gradual exercise. The hypothesis was that ES would attenuate the VO2-workload relation and improve DE. Methods: Fifteen healthy, untrained men (mean (SD) age 22 (5) years) were selected. Ten were electrostimulated on both quadriceps muscles with a frequency of 45–60 Hz, with 12 seconds of stimulation followed by eight seconds recovery for a total of 30 minutes a day, three days a week for six weeks. The remaining five subjects were assigned to a control group. A standardised exercise test on a cycle ergometer (ramp protocol, workload increases of 20 W/min) was performed by each subject before and after the experimental period. The slope of the VO2-power output (W) relation (ΔVO2/ΔW) and DE were calculated in each subject at moderate to high intensities (above the ventilatory threshold—that is, from 50–60% to 100% VO2max). Results: The mean (SEM) values for ΔVO2/ΔW and DE had significantly decreased and increased respectively after the six week ES programme (p<0.05; 9.8 (0.2) v 8.6 (0.5) ml O2/W/min respectively and 27.7 (0.9) v 31.5 (1.4)% respectively). Conclusions: ES could be used as a supplementary tool to improve two of the main determinants of endurance capacity, namely VO2 kinetics and work efficiency. PMID:12663356

  10. Contribution of central and peripheral adaptations to changes in VO2max following four weeks of sprint interval training.

    PubMed

    Raleigh, James P; Giles, Matthew D; Islam, Hashim; Nelms, Matthew William; Bentley, Robert F; Jones, Joshua H; Neder, J Alberto; Boonstra, Kristen; Quadrilatero, Joe; Simpson, Craig A; Tschakovsky, Michael E; Gurd, Brendon J

    2018-05-07

    The current study examined the contribution of central and peripheral adaptations to changes in maximal oxygen uptake (VO2max) following sprint interval training (SIT). Twenty-three males completed four weekly SIT sessions (8 x 20 second cycling bouts at ~170% of work rate at VO2max, 10 second recovery) for four weeks. Following completion of training, the relationship between changes in VO2max and changes in central (cardiac output) and peripheral (a-vO2diff, muscle capillary density, oxidative capacity, fibre-type distribution) adaptations was determined in all participants using correlation analysis. Participants were then divided in to tertiles based on the magnitude of their individual VO2max responses and differences in central/peripheral adaptations were examined in the top (HI; ~10 mL/kg/min increase in VO2max, p<0.05) and bottom (LO; no change in VO2max, p>0.05) tertiles (n=8 each). Training had no impact on Qmax and no differences were observed between the LO and HI groups (p>0.05). A-vO2diff increased in the HI group only (p<0.05) and correlated significantly (r=0.71, p<0.01) with changes in VO2max across all participants. Muscle capillary density (p<0.02) and ß-hydroxyacyl-CoA dehydrogenase maximal activity (p<0.05) increased in both groups, with no between-group differences (p>0.05). Citrate synthase maximal activity (p<0.01) and type IIA fibre composition (p<0.05) increased in the LO group only. Collectively, while the heterogeneity in the observed VO2max response following four weeks of SIT appears to be attributable to individual differences in systemic vascular and/or muscular adaptations, the markers examined in the current study were unable to explain the divergent VO2max responses in the LO and HI groups.

  11. Assumed oxygen consumption based on calculation from dye dilution cardiac output: an improved formula.

    PubMed

    Bergstra, A; van Dijk, R B; Hillege, H L; Lie, K I; Mook, G A

    1995-05-01

    This study was performed because of observed differences between dye dilution cardiac output and the Fick cardiac output, calculated from estimated oxygen consumption according to LaFarge and Miettinen, and to find a better formula for assumed oxygen consumption. In 250 patients who underwent left and right heart catheterization, the oxygen consumption VO2 (ml.min-1) was calculated using Fick's principle. Either pulmonary or systemic flow, as measured by dye dilution, was used in combination with the concordant arteriovenous oxygen concentration difference. In 130 patients, who matched the age of the LaFarge and Miettinen population, the obtained values of oxygen consumption VO2(dd) were compared with the estimated oxygen consumption values VO2(lfm), found using the LaFarge and Miettinen formulae. The VO2(lfm) was significantly lower than VO2(dd); -21.8 +/- 29.3 ml.min-1 (mean +/- SD), P < 0.001, 95% confidence interval (95% CI) -26.9 to -16.7, limits of agreement (LA) -80.4 to 36.9. A new regression formula for the assumed oxygen consumption VO2(ass) was derived in 250 patients by stepwise multiple regression analysis. The VO2(dd) was used as a dependent variable, and body surface area BSA (m2). Sex (0 for female, 1 for male), Age (years), Heart rate (min-1) and the presence of a left to right shunt as independent variables. The best fitting formula is expressed as: VO2(ass) = (157.3 x BSA + 10.0 x Sex - 10.5 x In Age + 4.8) ml.min-1, where ln Age = the natural logarithm of the age. This formula was validated prospectively in 60 patients. A non-significant difference between VO2(ass) and VO2(dd) was found; mean 2.0 +/- 23.4 ml.min-1, P = 0.771, 95% Cl = -4.0 to +8.0, LA -44.7 to +48.7. In conclusion, assumed oxygen consumption values, using our new formula, are in better agreement with the actual values than those found according to LaFarge and Miettinen's formulae.

  12. Physiological and biological factors associated with a 24 h treadmill ultra-marathon performance.

    PubMed

    Millet, G Y; Banfi, J C; Kerherve, H; Morin, J B; Vincent, L; Estrade, C; Geyssant, A; Feasson, L

    2011-02-01

    The purpose of this study was to examine the physiological and biological factors associated with ultra-endurance performance. Fourteen male runners volunteered to run on a treadmill as many kilometers as possible over a 24-h period (24TR). Maximal oxygen uptake (VO(2max)), velocity associated with VO(2max)(VO(2max)) and running economy (RE) at 8 km/h were measured. A muscle biopsy was also performed in the vastus lateralis muscle. The subjects ran 149.2 ± 15.7 km in 18 h 39 ± 41 min of effective attendance on the treadmill, corresponding to 39.4 ± 4.2% of . Standard multiple-regression analysis showed that performance was significantly (R(2) = 0.82; P = 0.005) related to VO(2max) and specific endurance, i.e. the average speed sustained over the 24TR expressed in . VO(2max) was associated with a high capillary tortuosity (R(2) = 0.66; P = 0.01). Specific endurance was significantly related to RE and citrate synthase activity. It is concluded that a high VO(2max) and an associated developed capillary network are essential for ultra-endurance running performance. The ability to maintain a high %VO(2max) over a 24TR is another factor associated with performance and is mainly related to RE and high mitochondrial oxidative capacity in the vastus lateralis. © 2009 John Wiley & Sons A/S.

  13. Electronic and Thermal Effects in the Insulator-Metal Phase Transition in VO2 Nano-Gap Junctions

    DTIC Science & Technology

    2014-11-27

    VO2 , air, or SiO2, the 2 -0.50 -0.25 0.00 0.25 0.50 0 2 4 6 V Gap V App V o lt ag e (V ) time (ms) t p V I→M V M→I 100 400 700 1000 0.0 2.5 5.0 7.5...Electronic and thermal effects in the insulator-metal phase transition in VO2 nano-gap junctions Arash Joushaghani,1 Junho Jeong,1 Suzanne Paradis,2...Canada (Dated: 27 November 2014) By controlling the thermal transport of VO2 nano-gap junctions using device geometry, contact material, and applied

  14. Effects of three warm-up regimens of equal distance on VO2 kinetics during supramaximal exercise in Thoroughbred horses.

    PubMed

    Mukai, K; Hiraga, A; Takahashi, T; Ohmura, H; Jones, J H

    2010-11-01

    Several studies have indicated that even low-intensity warm-up increases O(2) transport kinetics and that high-intensity warm-up may not be needed in horses. However, conventional warm-up exercise for Thoroughbred races is more intense than those utilised in previous studies of equine warm-up responses. To test the hypothesis that warm-up exercise at different intensities alters the kinetics and total contribution of aerobic power to total metabolic power in subsequent supramaximal (sprint) exercise in Thoroughbred horses. Nine well-trained Thoroughbreds ran until fatigue at 115% of maximal oxygen consumption (VO2max) 10 min after warming-up under each of 3 protocols of equal running distance: 400 s at 30% VO2max (LoWU), 200 s at 60% VO2max (MoWU) and 120 s at 100% VO2max (HiWU). Variables measured during exercise were rates of O(2) and CO(2) consumption/production (VO2,VO2), respiratory exchange ratio (RER), heart rate, blood lactate concentration and accumulation rate and blood gas variables. VO2 was significantly higher in HiWU than in LoWU at the onset of the sprint exercise and HR was significantly higher in HiWU than in LoWU throughout the sprint. Accumulation of blood lactate, RER, P(a)CO(2) and PvCO2 in the first 60 s were significantly lower in HiWU than in LoWU and MoWU. There were no significant differences in stroke volume, run time or arterial-mixed venous O(2) concentration. These results suggest HiWU accelerates kinetics and reduces reliance on net anaerobic power compared with LoWU at the onset of the subsequent sprint. © 2010 EVJ Ltd.

  15. Obesity/Overweight in Persons with Early and Chronic SCI: A Randomized Multi-Center Controlled Lifestyle Intervention

    DTIC Science & Technology

    2012-10-01

    Oxygen   Consumption  (VO2  -­‐  L/min)   f.VO2 Total...form):   Data  Entry  Date   f.DATE Volume  of   Oxygen   Consumption  (VO2  -­‐  L/min)   f.VO2 Total  Energy  Expenditure...957–68. Quiz 969–71. 83 Emon ST, Irban AG, Bozkurt SU, Akakin D, Konya D, Ozgen S. Effects of parenteral nutritional support with fish -oil emulsion

  16. Obesity/Overweight in Persons with Early and Chronic SCI: A Randomized Multi-Center Controlled Lifestyle Intervention

    DTIC Science & Technology

    2013-10-01

    consumption of fish , seafood, and poultry over red meats and beef  All dairy products...Date   f.DATE   Volume  of   Oxygen   Consumption  (VO2  -­‐  L/min)   f.VO2   Total  Energy  Expenditure  (TEE  -­‐  kCal...form):   Data  Entry  Date   f.DATE   Volume  of   Oxygen   Consumption  (VO2  -­‐  L/min)   f.VO2   Total

  17. Evaluation of Maximal Oxygen Uptake and Submaximal Estimates of VO2max Before, During, and After Long Duration International Space Station Missions

    NASA Technical Reports Server (NTRS)

    2008-01-01

    Evaluation of Maximal Oxygen Uptake and Submaximal Estimates of VO2max Before, During, and After Long Duration International Space Station Missions (VO2max) will document changes in maximum oxygen uptake for crewmembers onboard the International Space Station (ISS) on long-duration missions, greater than 90 days. This investigation will establish the characteristics of VO2max during flight and assess the validity of the current methods of tracking aerobic capacity change during and following the ISS missions.

  18. Near-Field Nanoscopy of Metal-Insulator Phase Transitions Towards Synthesis of Novel Correlated Transition Metal Oxides and Their Interaction with Plasmon Resonances

    DTIC Science & Technology

    2016-01-05

    and to utilize the phase transtion states of VO2 to control and manipulate local plasmon resonaces. First, we imaged the charge dynamics in (MIT) of...Then we studied the interaction of VO2 with plasmons . Both the film VO2 and the crystal VO2 were 1. REPORT DATE (DD-MM-YYYY) 4. TITLE AND SUBTITLE 13...Novel Correlated Transition Metal Oxides and Their Interaction with Plasmon Resonances The views, opinions and/or findings contained in this report are

  19. Localized phase change of VO2 films grown by atomic-layer deposition on InAlN/AlN/GaN heterostructures

    NASA Astrophysics Data System (ADS)

    Downey, Brian P.; Wheeler, Virginia D.; Meyer, David J.

    2017-06-01

    We demonstrate the thermally actuated phase change of VO2 films formed by atomic layer deposition and subsequent thermal annealing on InAlN/AlN/GaN heterostructures. To locally raise the device temperature above the VO2 semiconductor-metal transition temperature, a two-dimensional electron gas formed within the InAlN/AlN/GaN heterostructure was used as an integrated resistive heater. An ON/OFF resistance ratio of nearly 103 was achieved for 50 nm VO2 films over a temperature range of 25 to 105 °C. The time required to switch the VO2 film from high- to low-resistance states was shown to depend on the applied heater power, with sub-microsecond transition times achieved.

  20. Sapphire substrate-induced effects in VO{sub 2} thin films grown by oxygen plasma-assisted pulsed laser deposition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Skuza, J. R., E-mail: jrskuza@nsu.edu, E-mail: apradhan@nsu.edu; Scott, D. W.; Pradhan, A. K., E-mail: jrskuza@nsu.edu, E-mail: apradhan@nsu.edu

    2015-11-21

    We investigate the structural and electronic properties of VO{sub 2} thin films on c-plane sapphire substrates with three different surface morphologies to control the strain at the substrate-film interface. Only non-annealed substrates with no discernible surface features (terraces) provided a suitable template for VO{sub 2} film growth with a semiconductor-metal transition (SMT), which was much lower than the bulk transition temperature. In addition to strain, oxygen vacancy concentration also affects the properties of VO{sub 2}, which can be controlled through deposition conditions. Oxygen plasma-assisted pulsed laser deposition allows favorable conditions for VO{sub 2} film growth with SMTs that can bemore » easily tailored for device applications.« less

  1. Predictors of VO2Peak in children age 6- to 7-years-old.

    PubMed

    Dencker, Magnus; Hermansen, Bianca; Bugge, Anna; Froberg, Karsten; Andersen, Lars B

    2011-02-01

    This study investigated the predictors of aerobic fitness (VO2PEAK) in young children on a population-base. Participants were 436 children (229 boys and 207 girls) aged 6.7 ± 0.4 yrs. VO2PEAK was measured during a maximal treadmill exercise test. Physical activity was assessed by accelerometers. Total body fat and total fat free mass were estimated from skinfold measurements. Regression analyses indicated that significant predictors for VO2PEAK per kilogram body mass were total body fat, maximal heart rate, sex, and age. Physical activity explained an additional 4-7%. Further analyses showed the main contributing factors for absolute values of VO2PEAK were fat free mass, maximal heart rate, sex, and age. Physical activity explained an additional 3-6%.

  2. Fabrication of bristlegrass-like VO2 (B)-ZnO heteroarchitectures as anode materials for lithium-ion batteries

    NASA Astrophysics Data System (ADS)

    Ma, Yining; Li, Wenjing; Ji, Shidong; Zhou, Huaijuan; Li, Rong; Li, Ning; Yao, Heliang; Cao, Xun; Jin, Ping

    2017-08-01

    Three-dimensional bristlegrass-like hierarchical VO2 (B)-ZnO heteroarchitectures with ZnO nanorods grown radially on VO2 (B) nanorods were successfully fabricated via a simple two-step synthesized method. When applied as an anode material for lithium-ion batteries, the VO2 (B)-ZnO hybrid electrode exhibited high reversible capacity and excellent recyclability, which could be originated from the unique hierarchical structure of the bristlegrass. After 80 cycles, the nanocomposite still maintained a higher reversible capacity of 329.4 mA h g-1 at a current density of 50 mA g-1. Therefore, the particular architecture of VO2 (B)-ZnO nanocomposite can be a promising candidate as the anode material in lithium-ion batteries.

  3. Thermochromic properties of W-doped VO2 thin films deposited by aqueous sol-gel method for adaptive infrared stealth application

    NASA Astrophysics Data System (ADS)

    Liu, Dongqing; Cheng, Haifeng; Xing, Xin; Zhang, Chaoyang; Zheng, Wenwei

    2016-07-01

    The W doped VO2 thin films with various W contents were successfully deposited by aqueous sol-gel method followed by a post annealing process. The derived thin films were characterized by X-ray diffraction, Raman spectra, scanning electron microscopy and atomic force microscopy. Besides, the resistance-temperature relationship and infrared emissivity in the waveband 7.5-14 μm were analyzed, and the effects of W doping on the thermochromic properties of VO2 thin films were studied. The results show that W atoms enter the crystal lattice of VO2 and the transition temperature decreases gradually with increasing doping amount of W. The emissivity of VO2-W-4% thin films has dropped to 0.4 when its real temperature is above 30 °C. The thermal infrared images were also examined under different temperature by thermal imager. The results indicate that the temperature under which W doped VO2 thin films begin to have lower emissivity decreases gradually with increasing doping amount of W. W doped VO2 thin films can control its infrared radiation intensity actively at a lower temperature level of 30 °C, which has great application prospects in the adaptive infrared stealth technology.

  4. Enhanced photoelectrochemical response of plasmonic Au embedded BiVO4/Fe2O3 heterojunction.

    PubMed

    Verma, Anuradha; Srivastav, Anupam; Khan, Saif A; Rani Satsangi, Vibha; Shrivastav, Rohit; Kumar Avasthi, Devesh; Dass, Sahab

    2017-06-14

    The effect of embedding Au nanoparticles (NPs) in a BiVO 4 /Fe 2 O 3 heterojunction for photoelectrochemical water splitting is studied here for the first time. The present nanostructured heterojunction offers three major advantages over pristine BiVO 4 and Fe 2 O 3 : (i) the formation of a heterojunction between BiVO 4 and Fe 2 O 3 enhances the charge carrier separation and transfer, (ii) the layer of Fe 2 O 3 provides protection to BiVO 4 from photocorrosion and, (iii) the Au NPs possessing surface plasmon resonance (SPR) enhance the photoelectrochemical response by transferring energy to metal oxides by hot electron transfer (HET) and plasmon resonant energy transfer (PRET). The present study reveals that the heterojunction ITO/BiVO 4 /Fe 2 O 3 (with 32% v/v Au solution in both layers) gives the best performance and mitigates the limitations of both pristine Fe 2 O 3 and BiVO 4 . A thirteen-fold increment in applied bias photon-to-current conversion efficiency (ABPE) was observed at 1.24 V vs. RHE under the condition of 1 Sun illumination. Monochromatic incident photon-to-current conversion efficiency (IPCE) measurements indicated that an Au embedded heterojunction is more effective in harvesting visible light in comparison to a heterojunction without Au NPs.

  5. Metabolic alterations due to caloric restriction and every other day feeding in normal and growth hormone receptor knockout mice.

    PubMed

    Westbrook, Reyhan; Bonkowski, Michael S; Arum, Oge; Strader, April D; Bartke, Andrzej

    2014-01-01

    Mutations causing decreased somatotrophic signaling are known to increase insulin sensitivity and extend life span in mammals. Caloric restriction and every other day (EOD) dietary regimens are associated with similar improvements to insulin signaling and longevity in normal mice; however, these interventions fail to increase insulin sensitivity or life span in growth hormone receptor knockout (GHRKO) mice. To investigate the interactions of the GHRKO mutation with caloric restriction and EOD dietary interventions, we measured changes in the metabolic parameters oxygen consumption (VO2) and respiratory quotient produced by either long-term caloric restriction or EOD in male GHRKO and normal mice. GHRKO mice had increased VO2, which was unaltered by diet. In normal mice, EOD diet caused a significant reduction in VO2 compared with ad libitum (AL) mice during fed and fasted conditions. In normal mice, caloric restriction increased both the range of VO2 and the difference in minimum VO2 between fed and fasted states, whereas EOD diet caused a relatively static VO2 pattern under fed and fasted states. No diet significantly altered the range of VO2 of GHRKO mice under fed conditions. This provides further evidence that longevity-conferring diets cause major metabolic changes in normal mice, but not in GHRKO mice.

  6. Relationships between body fat accumulation, aerobic capacity and insulin resistance in Japanese participants.

    PubMed

    Yoshimura, Eiichi; Kumahara, Hideaki; Tobina, Takuro; Ayabe, Makoto; Matono, Sakiko; Anzai, Keizo; Higaki, Yasuki; Kiyonaga, Akira; Tanaka, Hiroaki

    2011-01-01

    This study evaluated the relationships between body fat accumulation, aerobic capacity and insulin resistance (HOMA-IR) in 61 Japanese participants. The participants were middle-aged to elderly (age: 33-73; BMI: 21.6-38.5). Body fat mass (FM) was evaluated by hydrostatic weighing. Computed tomography was used to evaluate visceral and subcutaneous fat areas (VFA and SFA), liver to spleen ratio (L/S), and low-density muscle area (LDMA). To assess aerobic capacity, VO2 at the lactate threshold (VO2@LT) and VO2 peak were measured using a bicycle ergometer. FM, VFA, SFA, LDMA and L/S significantly correlated with HOMA-IR, but VO2@LT and VO2 peak did not. Analysis of covariance after adjustment for VFA or other body fat distribution and aerobic capacity showed that HOMA-IR had a significant linear trend across the tertile groups of L/S. However, for FM, VFA, SFA, LDMA and VO2@LT or VO2 peak, no significant trend was observed between the tertiles and insulin resistance. Ectopic fat deposition in the liver may influence insulin resistance independently of other body fat accumulation and aerobic capacity in Japanese participants. © 2011 Asian Oceanian Association for the Study of Obesity . Published by Elsevier Ltd. All rights reserved.

  7. Reduction in peak oxygen uptake after prolonged bed rest

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Kozlowski, S.

    1982-01-01

    The hypothesis that the magnitude of the reduction in peak oxygen uptake (VO2) after bed rest is directly proportional to the level of pre-bed rest peak VO2 is tested. Complete pre and post-bed rest working capacity and body weight data were obtained from studies involving 24 men (19-24 years old) and 8 women (23-34 years old) who underwent bed rest for 14-20 days with no remedial treatments. Results of regression analyses of the present change in post-bed rest peak VO2 on pre-bed rest peak VO2 with 32 subjects show correlation coefficients of -0.03 (NS) for data expressed in 1/min and -0.17 for data expressed in ml/min-kg. In addition, significant correlations are found that support the hypothesis only when peak VO2 data are analyzed separately from studies that utilized the cycle ergometer, particularly with subjects in the supine position, as opposed to data obtained from treadmill peak VO2 tests. It is concluded that orthostatic factors, associated with the upright body position and relatively high levels of physical fitness from endurance training, appear to increase the variability of pre and particularly post-bed rest peak VO2 data, which would lead to rejection of the hypothesis.

  8. Aerobic Capacity Following Long Duration International Spaces Station (ISS) Missions: Preliminary Results

    NASA Technical Reports Server (NTRS)

    Moore, Alan D.; Lee, S.M.C.; Everett, M.E.; Guined, J.R.; Knudsen, P.

    2010-01-01

    Maximum oxygen uptake (VO2max) is reduced immediately following space flights lasting <15 d, but has not been measured following long-duration missions. The purpose of this study is to measure VO2max and maximum work rate (WRmax) data from astronauts following ISS flights (91 to 188 d). Methods: Five astronauts [3 M, 2 F: 47+/-6 yr, 174+/-6 cm, 71.9+/-10.9 kg (mean +/- SD)] have participated in the study. Subjects performed upright cycle exercise tests to symptom-limited maximum. An initial test was done approx.270 d before flight to establish work rates for subsequent tests. Subsequent tests, conducted approx.45 d before flight and repeated on the first or second day (R+1/2) and at approx.10 d (R+10) following landing, consisted of 3 5 min stages designed to elicit 25%, 50%, and 75% of preflight VO2max, followed by 25 W(dot)/min increases. VO2, WR, and heart rate (HR) were measured using the ISS Portable Pulmonary Function System [Damec, Odense, DK]. Descriptive statistics are reported. Results: On R+1/2 mean VO2max decreased compared to preflight (Pre: 2.98+/-0.99, R+1/2: 2.63+/-0.56 L(dot)/min); 4 of 5 subjects demonstrated a loss of > 6%. WRmax also decreased on R+1/2 compared to preflight (Pre: 245+/-69, R+1/2: 210+/-45 W). On R+10, VO2max was 2.86+/-0.62 L(dot)/min, with 2 subjects still demonstrating a loss of > 6% from preflight. WRmax on R+10 was 240+/-49 W. HRmax did not change from pre to post-flight. Conclusions: These preliminary results, from the first 5 of 12 planned subjects of an ongoing ISS study, suggest that the majority of astronauts will experience a decrease in VO2max after long-duration space-flight. Interestingly, the two astronauts with the highest preflight VO2max had the greatest loss on R+1/2, and the astronaut with the lowest preflight VO2max increased by 13%. Thus, maintenance of VO2max may be more difficult in astronauts who have a high aerobic capacity, perhaps requiring more intense in-flight exercise countermeasure prescriptions.

  9. How Is Pulmonary Function and Exercise Tolerance Affected in Patients With AIS Who Have Undergone Spinal Fusion?

    PubMed

    Jeans, Kelly A; Lovejoy, John F; Karol, Lori A; McClung, Anna M

    2017-11-01

    Prospectively enrolled AIS patients who underwent spinal fusion, with 2 year follow-up. To evaluate the cardiovascular fitness and activity level in patients with AIS pre- and post-spinal fusion and to determine if initial curve magnitude or pulmonary function is predictive of exercise capacity. Researchers have tried to link pulmonary function testing (PFT) to exercise capacity; the results are mixed. Some report no improvement in PFTs or aerobic activity after surgical correction, and PFT measures were not predictive of exercise capacity. Conflicting results have shown Vo 2max results to fall within normal range in AIS patients while PFTs show minimal impairment. AIS patients underwent PFT and oxygen consumption (VO 2 ) testing during a submaximal graded exercise test (GXT) pre- and post-spinal fusion. Vo 2max was predicted in those patients who completed the test to 85% of maximal heart rate. Pre- to postoperative changes were assessed and then compared to age-matched control subjects. Correlations between Vo 2max and curve severity, pulmonary function, and activity level were assessed. Thirty-seven patients participated. Vo 2max was predicted in 23 patients pre- and postoperation. There was a significant reduction in Vo 2max postfusion (39.5 ± 6.5 mL/kg/min vs 42.1 ± 8.1 mL/kg/min, p = .033); however, compared with controls (40.5 ± 6.5 mL/kg/min), all data were within the normal range (p > .05). AIS patients reporting high activity had significantly greater Vo 2max than those reporting low activity both pre and postoperatively, but this difference only met statistical significance preop (p < .05). Curve magnitude and PFT measures were not found to correlate with Vo 2max (p > .05). Vo 2max in patients with AIS is within normal range both pre- and postfusion. Pulmonary limitations are accommodated for with a slightly increased breathing rate and a slightly reduced overall workload. Activity level rather than curve severity affects Vo 2max outcomes following fusion in AIS. Copyright © 2017 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

  10. The role of postural control in the association between aerobic capacity and walking capacity in chronic stroke: a cross-sectional analysis.

    PubMed

    Outermans, Jacqueline C; van de Port, Ingrid; Kwakkel, Gert; Visser-Meily, Johanna M; Wittink, Harriet

    2018-03-12

    Reports on the association between aerobic capacity and walking capacity in people after stroke show disparate results. To determine (1) if the predictive validity of peak oxygen uptake (VO2peak) for walking capacity post stroke is different from that of maximal oxygen uptake (VO2max) and (2) if postural control, hemiplegic lower extremity muscle strength, age and gender distort the association between aerobic capacity and walking capacity. Cross-sectional study. General community in Utrecht, the Netherlands. Community-dwelling people more than three months after stroke. Measurement of aerobic capacity were performed with cardiopulmonary exercise testing (CPET) and differentiated between the achievement of VO2peak or VO2max. Measurement of walking capacity with the Six Minute Walk Test (6MWT), postural control with the Performance Oriented Mobility Assessment (POMA) and hemiplegic lower extremity muscle strength with the Motricity Index (MI-LE). Fifty-one out of 62 eligible participants, aged 64.7 (±12.5) years were included. Analysis of covariance (ANCOVA) showed a nonsignificant difference between the predictive validities of VO2max (N = 22, β = 0.56; 95%CI 0.12 - 0.97) and VO2peak (N = 29, β = 0.72; 95%CI 0.38 - 0.92). Multiple regression analysis of the pooled sample showed a significant decrease in the β value of VO2peak (21.6%) for the 6MWT when adding the POMA as a covariate in the association model. VO2peak remained significantly related to 6MWT after correcting for the POMA (β = 0.56 (95%CI 0.39 - 0.75)) CONCLUSIONS: The results suggest similar predictive validity of aerobic capacity for walking capacity in participants achieving VO2max compared to those only achieving VO2peak. Postural control confounds the association between aerobic capacity and walking capacity. Aerobic capacity remains a valid predictor of walking capacity. Aerobic capacity is an important factor associated with walking capacity after stroke. However, to understand this relationship, postural control needs to be measured. Both aerobic capacity and postural control may need to be addressed during interventions aiming to improve walking capacity after stroke.

  11. BiVO{sub 4} photoanodes for water splitting with high injection efficiency, deposited by reactive magnetron co-sputtering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gong, Haibo; Institute for Solar Fuels, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Hahn-Meitner-Platz 1, 14109 Berlin; Freudenberg, Norman

    2016-04-15

    Photoactive bismuth vanadate (BiVO{sub 4}) thin films were deposited by reactive co-magnetron sputtering from metallic Bi and V targets. The effects of the V-to-Bi ratio, molybdenum doping and post-annealing on the crystallographic and photoelectrochemical (PEC) properties of the BiVO{sub 4} films were investigated. Phase-pure monoclinic BiVO{sub 4} films, which are more photoactive than the tetragonal BiVO{sub 4} phase, were obtained under slightly vanadium-rich conditions. After annealing of the Mo-doped BiVO{sub 4} films, the photocurrent increased 2.6 times compared to undoped films. After optimization of the BiVO{sub 4} film thickness, the photocurrent densities (without a catalyst or a blocking layer ormore » a hole scavenger) exceeded 1.2 mA/cm{sup 2} at a potential of 1.23 V{sub RHE} under solar AM1.5 irradiation. The surprisingly high injection efficiency of holes into the electrolyte is attributed to the highly porous film morphology. This co-magnetron sputtering preparation route for photoactive BiVO{sub 4} films opens new possibilities for the fabrication of large-scale devices for water splitting.« less

  12. Facile fabrication of an efficient BiVO4 thin film electrode for water splitting under visible light irradiation.

    PubMed

    Jia, Qingxin; Iwashina, Katsuya; Kudo, Akihiko

    2012-07-17

    An efficient BiVO(4) thin film electrode for overall water splitting was prepared by dipping an F-doped SnO(2) (FTO) substrate electrode in an aqueous nitric acid solution of Bi(NO(3))(3) and NH(4)VO(3), and subsequently calcining it. X-ray diffraction of the BiVO(4) thin film revealed that a photocatalytically active phase of scheelite-monoclinic BiVO(4) was obtained. Scanning electron microscopy images showed that the surface of an FTO substrate was uniformly coated with the BiVO(4) film with 300-400 nm of the thickness. The BiVO(4) thin film electrode gave an excellent anodic photocurrent with 73% of an IPCE at 420 nm at 1.0 V vs. Ag/AgCl. Modification with CoO on the BiVO(4) electrode improved the photoelectrochemical property. A photoelectrochemical cell consisting of the BiVO(4) thin film electrode with and without CoO, and a Pt counter electrode was constructed for water splitting under visible light irradiation and simulated sunlight irradiation. Photocurrent due to water splitting to form H(2) and O(2) was confirmed with applying an external bias smaller than 1.23 V that is a theoretical voltage for electrolysis of water. Water splitting without applying external bias under visible light irradiation was demonstrated using a SrTiO(3)Rh photocathode and the BiVO(4) photoanode.

  13. Enhanced Visible Transmittance of Thermochromic VO2 Thin Films by SiO2 Passivation Layer and Their Optical Characterization

    PubMed Central

    Yu, Jung-Hoon; Nam, Sang-Hun; Lee, Ji Won; Boo, Jin-Hyo

    2016-01-01

    This paper presents the preparation of high-quality vanadium dioxide (VO2) thermochromic thin films with enhanced visible transmittance (Tvis) via radio frequency (RF) sputtering and plasma enhanced chemical vapor deposition (PECVD). VO2 thin films with high Tvis and excellent optical switching efficiency (Eos) were successfully prepared by employing SiO2 as a passivation layer. After SiO2 deposition, the roughness of the films was decreased 2-fold and a denser structure was formed. These morphological changes corresponded to the results of optical characterization including the haze, reflectance and absorption spectra. In spite of SiO2 coating, the phase transition temperature (Tc) of the prepared films was not affected. Compared with pristine VO2, the total layer thickness after SiO2 coating was 160 nm, which is an increase of 80 nm. Despite the thickness change, the VO2 thin films showed a higher Tvis value (λ 650 nm, 58%) compared with the pristine samples (λ 650 nm, 43%). This enhancement of Tvis while maintaining high Eos is meaningful for VO2-based smart window applications. PMID:28773679

  14. Effects of long-term multicomponent exercise on health-related quality of life in older adults with type 2 diabetes: evidence from a cohort study.

    PubMed

    Baptista, Liliana C; Dias, Gonçalo; Souza, Nelba R; Veríssimo, Manuel T; Martins, Raul A

    2017-08-01

    To establish the effect of a long-term multicomponent exercise (LTMEX) intervention (24 months) on health-related quality of life (HRQoL), in older adults with type 2 diabetes (T2D). This longitudinal retrospective cohort study analyzes the effects of a supervised LTMEX program on HRQoL in older adults with T2D (n = 279). Participants underwent one of two conditions: LTMEX (n = 241) trained three times per week; and unchanged lifestyle-the control group (CO; n = 38). Participants completed baseline, and 2-year follow-up evaluations including the Short Form Health Survey 36 (SF-36), anthropometric, hemodynamic components, and cardiorespiratory fitness (VO 2 peak). LTMEX improves HRQoL, specifically physical functioning (P < 0.001), general health (P < 0.05), vitality (P < 0.001), mental health (MH; P < 0.05), physical component score (P < 0.001), mental component score (P < 0.001), and total SF-36 (P < 0.001). LTMEX group also decreased body weight (BW; P < 0.005), waist circumference (WC; P < 0.001), waist-to-hip ratio (WHR; P < 0.001), and systolic blood pressure (SBP; P < 0.001), and increased VO 2 peak (P < 0.001). CO group increased WC (P = 0.012), BMI (P = 0.024), waist-to-hip ratio (WHR; P = 0.003) and SBP (P < 0.001), and decreased vitality (P < 0.001) and MH (P < 0.05). A LTMEX intervention improves physical and mental HRQoL in older adults with T2D, and also anthropometric, hemodynamic profile, and cardiorespiratory fitness.

  15. Microwave-assisted in situ synthesis of reduced graphene oxide-BiVO4 composite photocatalysts and their enhanced photocatalytic performance for the degradation of ciprofloxacin.

    PubMed

    Yan, Yan; Sun, Shaofang; Song, Yang; Yan, Xu; Guan, Weisheng; Liu, Xinlin; Shi, Weidong

    2013-04-15

    To improve the photodegradation efficiency for ciprofloxacin (CIP), a new-type microwave-assisted in situ growth method is developed for the preparation of reduced graphene oxide (RGO) -BiVO4 composite photocatalysts. The as-produced RGO-BiVO4 composite photocatalysts show extremely high enhancement of CIP degradation ratio over the pure BiVO4 photocatalyst under visible light. Specially, the 2 wt% RGO-BiVO4 composite photocatalyst exhibits the highest CIP degradation ratio (68.2%) in 60 min, which is over 3 times than that (22.7%) of the pure BiVO4 particles. The enhancement of photocatalytic activities of RGO-BiVO4 photocatalysts can be attributed to the effective separation of electron-hole pairs rather than the improvement of light absorption. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Intraoperative baseline oxygen consumption as a prognostic factor in emergency open abdominal surgery.

    PubMed

    Masuda, Toshiro; Kuramoto, Masafumi; Tanimoto, Hironari; Yamamoto, Kenichiro; Ikeshima, Satoshi; Kitano, Yuuki; Kuroda, Daisuke; Shimada, Shinya; Baba, Hideo

    2016-04-01

    A new anesthesia system, the E-CAIOVX (GE Healthcare) enables the continuous monitoring of oxygen consumption (VO2) and carbon dioxide elimination (VCO2) during the surgical operation. The aim of this study was to evaluate the prognostic role of intraoperative baseline VO2 and VCO2 in an emergency open abdominal operation. A total of 103 patients who had an emergency open abdominal operation were enrolled in the study. VO2 and VCO2 were continuously measured from the induction of anesthesia to the end of the operation. There were significant correlations between intraoperative baseline VO2 and body surface area (BSA; P < .001, r = 0.68), VO2 and tidal volume (P < .001, r = 0.59), and VO2 and baseline body temperature (P < .0001, r = 0.49). Also, there were significant correlations between intraoperative baseline VCO2 and BSA (P < .001, r = 0.70), VCO2 and tidal volume (P < .001, r = 0.70), and VCO2 and body temperature (P < .001, r = 0.41). Fifteen (14.6%) of the 103 patients died within 4 months after the operation without having been discharged from hospital. Baseline VO2/BSA was higher in surviving patients (123.7 ± 23.6 mL/min ∙ m(2)) than the deceased (103.8 ± 15.6 mL/min ∙ m(2); P = .002). There was no significant difference in baseline VCO2/BSA levels between surviving (106.2 ± 20.1 mL/min ∙ m(2)) and deceased patients (99.4 ± 21.4 mL/min ∙ m(2)). In multivariate analysis, baseline body temperature lower than 36.2°C (P = .02), serum albumin less than 3.0 g/dL (P = .002), and baseline VO2/BSA less than 111.9 mL/min ∙ m(2) (P = .03) were independent factors. Baseline low VO2/BSA less than 111.9 mL/min ∙ m(2) was one of the poor predictors for the prognosis of an emergency open abdominal surgery. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Energetic Profile of the Basketball Exercise Simulation Test in Junior Elite Players.

    PubMed

    Latzel, Richard; Hoos, Olaf; Stier, Sebastian; Kaufmann, Sebastian; Fresz, Volker; Reim, Dominik; Beneke, Ralph

    2017-11-28

    To analyze the energetic profile of the basketball exercise simulation test (BEST). 10 male elite junior basketball players (age: 15.5±0.6yrs, height: 180±9cm, body mass: 66.1±11.2kg) performed a modified BEST (20 circuits consisting of jumping, sprinting, jogging, shuffling, and short breaks) simulating professional basketball game play. Circuit time, sprint time, sprint decrement, oxygen uptake (VO2), heart rate (HR), and blood lactate concentration (BLC) were obtained. Metabolic energy and metabolic power above rest (W tot , P tot ) as well as energy share in terms of aerobic (W aer ), glycolytic (W blc ), and high energy phosphates (W PCr ) were calculated from VO2 during exercise, net lactate production, and the fast component of post-exercise VO2 kinetics, respectively. W aer , W blc , and W PCr reflect 89±2%, 5±1%, and 6±1% of total energy needed, respectively. Assuming an aerobic replenishment of PCr energy stores during short breaks, the adjusted energy share yielded W aer : 66±4%, W blc : 5±1%, and W PCr : 29±1%. W aer and W PCr were negatively correlated (-0.72, -0.59) with sprint time, which was not the case for W blc . Consistent with general findings on energy system interaction during repeated high intensity exercise bouts, the intermittent profile of the BEST relies primarily on aerobic energy combined with repetitive supplementation by anaerobic utilization of high energy phosphates.

  18. Spectroscopic, structural and in vitro cytotoxicity evaluation of luminescent, lanthanide doped core@shell nanomaterials GdVO4:Eu(3+)5%@SiO2@NH2.

    PubMed

    Szczeszak, Agata; Ekner-Grzyb, Anna; Runowski, Marcin; Szutkowski, Kosma; Mrówczyńska, Lucyna; Kaźmierczak, Zuzanna; Grzyb, Tomasz; Dąbrowska, Krystyna; Giersig, Michael; Lis, Stefan

    2016-11-01

    The luminescent GdVO4:Eu(3+)5%@SiO2@NH2 core@shell nanomaterials were obtained via co-precipitation method, followed by hydrolysis and co-condensation of silane derivatives: tetraethyl orthosilicate and 3-aminopropyltriethoxysilane. Their effect on human erythrocytes sedimentation and on proliferation of human lung microvascular endothelial cells was examined and discussed. The luminescent nanoparticles were synthesized in the presence of polyacrylic acid or glycerin in order to minimalize the agglomeration and excessive growth of nanostructures. Surface coating with amine functionalized silica shell improved their biocompatibility, facilitated further organic conjugation and protected the internal core. Magnetic measurements revealed an enhanced T1-relaxivity for the synthesized GdVO4:Eu(3+)5% nanostructures. Structure, morphology and average grain size of the obtained nanomaterials were determined by X-ray diffraction, transmission electron microscopy and dynamic light scattering analysis. The qualitative elemental composition of the nanomaterials was established using energy-dispersive X-ray spectroscopy. The spectroscopic characteristic of red emitting core@shell nanophosphors was completed by measuring luminescence spectra and decays. The emission spectra revealed characteristic bands of Eu(3+) ions related to the transitions (5)D0-(7)F0,1,2,3,4 and (5)D1-(7)F1. The luminescence lifetimes consisted of two components, associated with the presence of Eu(3+) ions located at the surface of the crystallites and in the bulk. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Determination of Aerobic Power Through a Specific Test for Taekwondo - A Predictive Equation Model

    PubMed Central

    Louro, Hugo; Matias, Ricardo; Brito, João; Costa, Aldo M.

    2016-01-01

    Abstract Our aim was to verify the concurrent validity of a maximal taekwondo specific test (TST) to predict VO2max through an explanatory model. Seventeen elite male taekwondo athletes (age: 17.59 ± 4.34 years; body height: 1.72 ± 6.5 m; body mass: 61.3 ± 8.7 kg) performed two graded maximal exercise tests on different days: a 20 m multistage shuttle run test (SRT) and an incremental TST. We recorded test time, VO2max, ventilation, a heart rate and time to exhaustion. Significant differences were found between observed and estimated VO2max values [F (2, 16) = 5.77, p < 0.01]; post-hoc subgroup analysis revealed the existence of significant differences (p = 0.04) between the estimated VO2max value in the SRT and the observed value recorded in the TST (58.4 ± 6.4 ml/kg/min and 52.6 ± 5.2 ml/kg/min, respectively). Our analysis also revealed a moderate correlation between both testing protocols regarding VO2max (r = 0.70; p = 0.005), test time (r = 0.77; p = 0.02) and ventilation (r = 0.69; p = 0.03). There was no proportional bias in the mean difference (t = -1.04; p = 0.313), and there was a level of agreement between both tests. An equation/model was used to estimate VO2max during the TST based on the mean heart rate, test time, body height and mass, which explained 74.3% of the observed VO2max variability. A moderate correlation was found between the observed and predicted VO2max values in the taekwondo TST (r = 0.74, p = 0.001). Our results suggest that an incremental specific test estimates VO2max of elite taekwondo athletes with acceptable concurrent validity. PMID:28149417

  20. Statins are related to impaired exercise capacity in males but not females.

    PubMed

    Bahls, Martin; Groß, Stefan; Ittermann, Till; Busch, Raila; Gläser, Sven; Ewert, Ralf; Völzke, Henry; Felix, Stephan B; Dörr, Marcus

    2017-01-01

    Exercise and statins reduce cardiovascular disease (CVD). Exercise capacity may be assessed using cardiopulmonary exercise testing (CPET). Whether statin medication is associated with CPET parameters is unclear. We investigated if statins are related with exercise capacity during CPET in the general population. Cross-sectional data of two independent cohorts of the Study of Health in Pomerania (SHIP) were merged (n = 3,500; 50% males). Oxygen consumption (VO2) at peak exercise (VO2peak) and anaerobic threshold (VO2@AT) was assessed during symptom-limited CPET. Two linear regression models related VO2peak with statin usage were calculated. Model 1 adjusted for age, sex, previous myocardial infarction, and physical inactivity and model 2 additionally for body mass index, smoking, hypertension, diabetes and estimated glomerular filtration rate. Propensity score matching was used for validation. Statin usage was associated with lower VO2peak (no statin: 2336; 95%-confidence interval [CI]: 2287-2,385 vs. statin 2090; 95%-CI: 2,031-2149 ml/min; P < .0001) and VO2@AT (no statin: 1,172; 95%-CI: 1,142-1,202 vs. statin: 1,111; 95%-CI: 1,075-1,147 ml/min; P = .0061) in males but not females (VO2peak: no statin: 1,467; 95%-CI: 1,417-1,517 vs. statin: 1,503; 95%-CI: 1,426-1,579 ml/min; P = 1.00 and VO2@AT: no statin: 854; 95%-CI: 824-885 vs. statin 864; 95%-CI: 817-911 ml/min; P = 1.00). Model 2 revealed similar results. Propensity scores analysis confirmed the results. In the general population present statin medication was related with impaired exercise capacity in males but not females. Sex specific effects of statins on cardiopulmonary exercise capacity deserve further research.

  1. Improvement of diabetes, obesity and hypertension in type 2 diabetic KKA{sup y} mice by bis(allixinato)oxovanadium(IV) complex

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adachi, Yusuke; Yoshikawa, Yutaka; Yoshida, Jiro

    Previously, we found that bis(allixinato)oxovanadium(IV) (VO(alx){sub 2}) exhibits a potent hypoglycemic activity in type 1-like diabetic mice. Since the enhancement of insulin sensitivity is involved in one of the mechanisms by which vanadium exerts its anti-diabetic effects, VO(alx){sub 2} was further tested in type 2 diabetes with low insulin sensitivity. The effect of oral administration of VO(alx){sub 2} was examined in obesity-linked type 2 diabetic KKA{sup y} mice. Treatment of VO(alx){sub 2} for 4 weeks normalized hyperglycemia, glucose intolerance, hyperinsulinemia, hypercholesterolemia and hypertension in KKA{sup y} mice; however, it had no effect on hypoadiponectinemia. VO(alx){sub 2} also improved hyperleptinemia, followingmore » attenuation of obesity in KKA{sup y} mice. This is the first example in which a vanadium compound improved leptin resistance in type 2 diabetes by oral administration. On the basis of these results, VO(alx){sub 2} is proposed to enhance not only insulin sensitivity but also leptin sensitivity, which in turn improves diabetes, obesity and hypertension in an obesity-linked type 2 diabetic animal.« less

  2. Effect of a 17 day spaceflight on contractile properties of human soleus muscle fibres

    NASA Technical Reports Server (NTRS)

    Widrick, J. J.; Knuth, S. T.; Norenberg, K. M.; Romatowski, J. G.; Bain, J. L.; Riley, D. A.; Karhanek, M.; Trappe, S. W.; Trappe, T. A.; Costill, D. L.; hide

    1999-01-01

    1. Soleus biopsies were obtained from four male astronauts 45 days before and within 2 h after a 17 day spaceflight. 2. For all astronauts, single chemically skinned post-flight fibres expressing only type I myosin heavy chain (MHC) developed less average peak Ca2+ activated force (Po) during fixed-end contractions (0.78 +/- 0. 02 vs. 0.99 +/- 0.03 mN) and shortened at a greater mean velocity during unloaded contractions (Vo) (0.83 +/- 0.02 vs. 0.64 +/- 0.02 fibre lengths s-1) than pre-flight type I fibres. 3. The flight-induced decline in absolute Po was attributed to reductions in fibre diameter and/or Po per fibre cross-sectional area. Fibres from the astronaut who experienced the greatest relative loss of peak force also displayed a reduction in Ca2+ sensitivity. 4. The elevated Vo of the post-flight slow type I fibres could not be explained by alterations in myosin heavy or light chain composition. One alternative possibility is that the elevated Vo resulted from an increased myofilament lattice spacing. This hypothesis was supported by electron micrographic analysis demonstrating a reduction in thin filament density post-flight. 5. Post-flight fibres shortened at 30 % higher velocities than pre-flight fibres at external loads associated with peak power output. This increase in shortening velocity either reduced (2 astronauts) or prevented (2 astronauts) a post-flight loss in fibre absolute peak power (microN (fibre length) s-1). 6. The changes in soleus fibre diameter and function following spaceflight were similar to those observed after 17 days of bed rest. Although in-flight exercise countermeasures probably reduced the effects of microgravity, the results support the idea that ground-based bed rest can serve as a model of human spaceflight. 7. In conclusion, 17 days of spaceflight decreased force and increased shortening velocity of single Ca2+-activated muscle cells expressing type I MHC. The increase in shortening velocity greatly reduced the impact that impaired force production had on absolute peak power.

  3. Effect of 400 ml blood loss on adaptation of certain functions of the organism to exercise.

    PubMed

    Markiewicz, K; Cholewa, M; Górski, L; Jaszczuk, J; Chmura, J; Bartniczak, Z

    1981-01-01

    Eighteen men aged 19-23 years, volunteer blood donors, donated 400 ml of blood. Twenty-four hours before donation, one hour and 24 hours after it they performed a 10-minute exercise on Monark cycle ergometer at workloads raising the heart rate to 170/min. During the exercise the oxygen uptake (VO2), carbon dioxide elimination (VCO2), respiratory quotient (RQ), oxygen uptake to maximal oxygen uptake ratio (VO2/VO2 max), heart rate (HR) and systolic and diastolic arterial blood pressure (Ps and Pd) were determined. The obtained results were compared with the values of haemoglobin concentration and erythrocyte count. One hour after blood donation raised values of HR and Pd were obtained (p less than 0.05) with decreased Ps (p less than 0.05) and VO2 (p less than 0.05). Twenty-four hours after blood loss these parameters were not different from the initial ones (p less than 0.05). Submaximal exercise performed 1 hour after blood loss produced a significantly greater increase of the heart rate than this exercise performed before blood loss. The values of VO2, VCO2, and VO2/VO2 max were slightly lower and those of RQ and HRXPs slightly higher than during control exercise (p less than 0.05). Exercise performed 24 hours after blood loss caused identical changes in these parameters as during control tests.

  4. Validation of a single-stage fixed-rate step test for the prediction of maximal oxygen uptake in healthy adults.

    PubMed

    Hansen, Dominique; Jacobs, Nele; Thijs, Herbert; Dendale, Paul; Claes, Neree

    2016-09-01

    Healthcare professionals with limited access to ergospirometry remain in need of valid and simple submaximal exercise tests to predict maximal oxygen uptake (VO2max ). Despite previous validation studies concerning fixed-rate step tests, accurate equations for the estimation of VO2max remain to be formulated from a large sample of healthy adults between age 18-75 years (n > 100). The aim of this study was to develop a valid equation to estimate VO2max from a fixed-rate step test in a larger sample of healthy adults. A maximal ergospirometry test, with assessment of cardiopulmonary parameters and VO2max , and a 5-min fixed-rate single-stage step test were executed in 112 healthy adults (age 18-75 years). During the step test and subsequent recovery, heart rate was monitored continuously. By linear regression analysis, an equation to predict VO2max from the step test was formulated. This equation was assessed for level of agreement by displaying Bland-Altman plots and calculation of intraclass correlations with measured VO2max . Validity further was assessed by employing a Jackknife procedure. The linear regression analysis generated the following equation to predict VO2max (l min(-1) ) from the step test: 0·054(BMI)+0·612(gender)+3·359(body height in m)+0·019(fitness index)-0·012(HRmax)-0·011(age)-3·475. This equation explained 78% of the variance in measured VO2max (F = 66·15, P<0·001). The level of agreement and intraclass correlation was high (ICC = 0·94, P<0·001) between measured and predicted VO2max . From this study, a valid fixed-rate single-stage step test equation has been developed to estimate VO2max in healthy adults. This tool could be employed by healthcare professionals with limited access to ergospirometry. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  5. Evaluation of Maximal O[subscript 2] Uptake with Undergraduate Students at the University of La Reunion

    ERIC Educational Resources Information Center

    Tarnus, Evelyne; Catan, Aurelie; Verkindt, Chantal; Bourdon, Emmanuel

    2011-01-01

    The maximal rate of O[subscript 2] consumption (VO[subscript 2max]) constitutes one of the oldest fitness indexes established for the measure of cardiorespiratory fitness and aerobic performance. Procedures have been developed in which VO[subscript 2max]is estimated from physiological responses during submaximal exercise. Generally, VO[subscript…

  6. Antibacterial activity of crude extracts of prasaprohyai formula and its components against pathogenic bacteria.

    PubMed

    Sattaponpan, Chisanucha; Kondo, Sumalee

    2011-12-01

    Prasaprohyai formula is a Thai Traditional Medicine which has been used for reducing feverish in child. Fever is a symptom resulting from various infections and diseases. The major cause of fever is bacterial and viral infections. The Prasaprohyai formula and its components potentially have biological activities including antipyretic and antimicrobial activities. It is in a hope to develop the formula and its components for an alternative medicine of infectious diseases. To study antibacterial activity of Prasaprohyai formula and its components against pathogenic bacteria. Prasaprohyai formula and its components were extracted by different methods, A: maceration with 95% ethanol followed by evaporation (ET), B: ET followed by freeze drying (EF) and C: water distillation (VO). All extracts were tested against clinical isolates from Thammasat University Hospital, Staphylococcus aureus ATCC 25923 and Escherichia coli ATCC 25922. Disk diffusion and broth dilution methods were performed. Crude extracts of ET had higher yield of extraction than other methods. The results showed that the crude extract from different methods of Syzygium aromaticum (Linn) Merr & Perry (Flower) was effective against all bacterial strains with the inhibition zone ranging from 9 to 19 mm. The VO extract of Prasaprohyai formula showed antibacterial activity against most of the pathogenic bacteria in the present study. The activity against Streptococcus pyogenes was found in the VO extract of some components. The ET extracts of Lepidium sativum Linn, Myristica fragrans Houtt (seed) and Myristica fragrans Houtt (aril) had no antibacterial activity against all microorganism. However the EF extracts of this formula and some components were able to mostly inhibit Gram positive bacteria. The results indicated that Prasaprohyai formula and its components were able to inhibit the growth of both Gram positive and Gram negative bacteria including multiresistant strains. The volatile oil extracts seemed to play an important role in antimicrobial activities. The development of Prasaprohyai formula for alternative medicine will be approached in future.

  7. Physiological characteristics of America's Cup sailors.

    PubMed

    Bernardi, Marco; Quattrini, Filippo M; Rodio, Angelo; Fontana, Giuseppe; Madaffari, Andrea; Brugnoli, Marco; Marchetti, Marco

    2007-08-01

    The aim of this study was to assess the physiological profile of America's Cup grinders and mastmen, by measuring energy expenditure during sailing and assessing their aerobic and anaerobic fitness. The study focused on estimating the energy used during grinding activity, by measuring oxygen uptake (VO(2)) during sail setting in real sailing conditions. In the laboratory, using an arm-cranking ergometer, we measured VO(2peak) during an incremental maximal exercise test and total energy expended during the effort and recovery phases of an all-out test that simulated grinding activity, in six grinders and mastmen and ten sailors of the same crew. Total energy used during grinding corresponded to 45% (s = 9) and 51% (s = 5) of that used in the all-out test (234 kJ, s = 21.7) for tacks and gybes, respectively. In both grinding activity and the all-out test, VO(2) increased during and after the effort. The "VO(2) top value" was 53% (s = 8.6), 68% (s = 5.5), and 78% (s = 3.1) of VO(2peak) (4.7 l . min(-1), s = 0.43) in tacks, gybes, and the all-out test, respectively. During fast sequences of grinding activity, the "VO(2) top value" reached 65% (s = 7.1) VO(2peak) in tacks and 91% (s = 3.3) VO(2peak) in gybes. Our results suggest that grinders and mastmen are characterized by a high anaerobic capacity but their performance can be improved by powering aerobic fitness, to increase this energy contribution to all-out efforts and to guarantee fast recovery when grinding activity is repeated with short rest intervals.

  8. Plasmonic enhancement of the vanadium dioxide phase transition induced by low-power laser irradiation

    NASA Astrophysics Data System (ADS)

    Ferrara, Davon W.; MacQuarrie, Evan R.; Diez-Blanco, Victor; Nag, Joyeeta; Kaye, Anthony B.; Haglund, Richard F.

    2012-08-01

    Nanocomposites consisting of gold nanoparticle (NP) arrays and vanadium dioxide (VO2) thin films are noteworthy for the tunability of both their thermal and optical properties. The localized surface plasmon resonance (LSPR) of the Au can be tuned when its dielectric environment is modulated by the semiconducting-to-metal phase transition (SMT) of the VO2; the LSPR itself can be altered by changing the shape of the NPs and the pitch of the NP array. In principle, then it should be possible to choose a combination of VO2 film and Au LSPR properties that maximizes the overall optical response of the nanocomposite. To demonstrate this effect, transient transmission measurements were conducted on lithographically fabricated arrays of Au NPs of diameter 140 nm, array spacing 350 nm, and covered with a 60 nm thick films of VO2 via pulsed laser deposition. Both Au::VO2 nanocomposites and bare VO2 film were irradiated with a shuttered 785 nm pump laser, and their optical response was probed at 1550 nm by a fixed-frequency diode laser. The Au::VO2 nanocomposite exhibited an increased effective absorption coefficient 1.5 times that of the plain film and required 37 % less laser power to induce the SMT. The time-dependent temperature rise in the film as a function of laser intensity was calculated from these measurements and compared with both analytic and finite-element models. Our results suggest that Au::VO2 nanocomposites may be useful in applications such as thermal-management coatings for energy efficient "smart" windows.

  9. How do cardiorespiratory fitness improvements vary with physical training modality in heart failure patients? A quantitative guide

    PubMed Central

    Smart, Neil A

    2013-01-01

    BACKGROUND: Peak oxygen consumption (VO2) is the gold standard measure of cardiorespiratory fitness and a reliable predictor of survival in chronic heart failure patients. Furthermore, any form of physical training usually improves cardiorespiratory fitness, although the magnitude of improvement in peak VO2 may vary across different training prescriptions. OBJECTIVE: To quantify, and subsequently rank, the magnitude of improvement in peak VO2 for different physical training prescriptions using data from published meta-analyses and randomized controlled trials. METHODS: Prospective randomized controlled parallel trials and meta-analyses of exercise training in chronic heart failure patients that provided data on change in peak VO2 for nine a priori comparative analyses were examined. RESULTS: All forms of physical training were beneficial, although the improvement in peak VO2 varied with modality. High-intensity interval exercise yielded the largest increase in peak VO2, followed in descending order by moderate-intensity aerobic exercise, functional electrical stimulation, inspiratory muscle training, combined aerobic and resistance training, and isolated resistance training. With regard to setting, the present study was unable to determine whether outpatient or unsupervised home exercise provided greater benefits in terms of peak VO2 improvment. CONCLUSIONS: Interval exercise is not suitable for all patients, especially the high-intensity variety; however, when indicated, this form of exercise should be adopted to optimize peak VO2 adaptations. Other forms of activity, such as functional electrical stimulation, may be more appropriate for patients who are not capable of high-intensity interval training, especially for severely deconditioned patients who are initially unable to exercise. PMID:24294043

  10. Comparison of normalized maximum aerobic capacity and body composition of sumo wrestlers to athletes in combat and other sports.

    PubMed

    Beekley, Matthew D; Abe, Takashi; Kondo, Masakatsu; Midorikawa, Taishi; Yamauchi, Taro

    2006-01-01

    Sumo wrestling is unique in combat sport, and in all of sport. We examined the maximum aerobic capacity and body composition of sumo wrestlers and compared them to untrained controls. We also compared "aerobic muscle quality", meaning VO2max normalized to predicted skeletal muscle mass (SMM) (VO2max /SMM), between sumo wrestlers and controls and among previously published data for male athletes from combat, aerobic, and power sports. Sumo wrestlers, compared to untrained controls, had greater (p < 0.05) body mass (mean ± SD; 117.0 ± 4.9 vs. 56.1 ± 9.8 kg), percent fat (24.0 ± 1.4 vs. 13.3 ± 4.5), fat-free mass (88.9 ± 4.2 vs. 48.4 ± 6.8 kg), predicted SMM (48.2 ± 2.9 vs. 20.6 ± 4.7 kg) and absolute VO2max (3.6 ± 1.3 vs. 2.5 ± 0.7 L·min(-1)). Mean VO2max /SMM (ml·kg SMM(-1)·min(-1)) was significantly different (p < 0.05) among aerobic athletes (164.8 ± 18.3), combat athletes (which was not different from untrained controls; 131.4 ± 9.3 and 128.6 ± 13.6, respectively), power athletes (96.5 ± 5.3), and sumo wrestlers (71.4 ± 5.3). There was a strong negative correlation (r = - 0.75) between percent body fat and VO2max /SMM (p < 0.05). We conclude that sumo wrestlers have some of the largest percent body fat and fat-free mass and the lowest "aerobic muscle quality "(VO2max /SMM), both in combat sport and compared to aerobic and power sport athletes. Additionally, it appears from analysis of the relationship between SMM and absolute VO2max for all sports that there is a "ceiling "at which increases in SMM do not result in additional increases in absolute VO2max. Key PointsSumo wrestlers have a high absolute VO2max compared to untrained controls.However, sumo wrestlers have a low VO2max /kg of skeletal muscle mass compared to other combat sports, other strength/power sports, and untrained controls.The reason for this is unknown, but is probably related to alterations in sumo skeletal muscle compared to other sports.Based on the present and previous data, there appears to be a "ceiling "at which increases in skeletal muscle mass do not result in additional increases in absolute VO2max.

  11. Direct Conversion of Wheat Straw into Electricity with a Biomass Flow Fuel Cell Mediated by Two Redox Ion Pairs.

    PubMed

    Gong, Jian; Liu, Wei; Du, Xu; Liu, Congmin; Zhang, Zhe; Sun, Feifei; Yang, Le; Xu, Dong; Guo, Hua; Deng, Yulin

    2017-02-08

    In this paper, a biomass flow fuel cell to directly convert wheat straw to electricity at low temperature (80-90 °C) and atmospheric pressure is presented. Two redox ion pairs, Fe 3+ /Fe 2+ and VO 2 + /VO 2+ , acting as redox catalysts and charge carriers, were used in the anode and cathode flow tanks, respectively. The wheat straw was first oxidized by Fe 3+ in the anode tank at approximately 100 °C. The reduced Fe 2+ in the anode was used to construct a fuel cell with VO 2 + in the cathode. The VO 2 + ions were reduced to VO 2+ and regenerated to VO 2 + by oxygen oxidation. The wheat straw flow fuel cell showed a power output of 100 mW cm -2 . Mediated with liquid Fe 3+ carriers, the solid powder of wheat straw could be gradually degraded into low-molecular-weight organic molecules and even oxidized to CO 2 at the anode without using noble-metal catalysts. The overpotential for the electrodes of the flow fuel cell was examined and the energy cost was estimated. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Metabolism and evaporative heat loss in the dik-dik antelope (Rhynchotragus kirki).

    PubMed

    Kamau, J M

    1988-01-01

    1. Under controlled conditions, the rate of oxygen consumption (VO2) respiratory frequency, evaporative water loss, heat balance, rectal (Trec) and surface temperatures were determined in the dik-dik antelopes at ambient temperatures (Ta) ranging from 1 to 44 degrees C. 2. The thermal neutral zone was found to be between 24 and 35 degrees C. 3. Respiratory frequency ranged between 27 and 630 breaths/min. 4. At a Ta of 44 degrees C, 95% of the heat produced by the dik-dik was lost via respiratory evaporation. Despite an increase in Trec, cutaneous evaporation did not increase. 5. During panting, VO2 increased in accordance with the expected Q10 effect, contrary to earlier findings. 6. Measurements of circadian rhythm [LD 12:12 (7-19) CT26 degrees C] in VO2 showed that the minimum VO2 (0.42 ml O2/g/hr) occurred at midnight while the maximum (0.78 ml O2/g/hr) occurred at midday. The 24 hr mean VO2 was 0.61 ml O2/g/hr. 7. These measurements suggest that in nature, determinants other than light may be responsible for triggering the variations observed in VO2.

  13. PREDICTION OF VO2PEAK USING OMNI RATINGS OF PERCEIVED EXERTION FROM A SUBMAXIMAL CYCLE EXERCISE TEST

    PubMed Central

    Mays, Ryan J.; Goss, Fredric L.; Nagle-Stilley, Elizabeth F.; Gallagher, Michael; Schafer, Mark A.; Kim, Kevin H.; Robertson, Robert J.

    2015-01-01

    Summary The primary aim of this study was to develop statistical models to predict peak oxygen consumption (VO2peak) using OMNI Ratings of Perceived Exertion measured during submaximal cycle ergometry. Men (mean ± standard error: 20.90 ± 0.42 yrs) and women (21.59 ± 0.49 yrs) participants (n = 81) completed a load-incremented maximal cycle ergometer exercise test. Simultaneous multiple linear regression was used to develop separate VO2peak statistical models using submaximal ratings of perceived exertion for the overall body, legs, and chest/breathing as predictor variables. VO2peak (L·min−1) predicted for men and women from ratings of perceived exertion for the overall body (3.02 ± 0.06; 2.03 ± 0.04), legs (3.02 ± 0.06; 2.04 ± 0.04) and chest/breathing (3.02 ± 0.05; 2.03 ± 0.03) were similar with measured VO2peak (3.02 ± 0.10; 2.03 ± 0.06, ps > .05). Statistical models based on submaximal OMNI Ratings of Perceived Exertion provide an easily administered and accurate method to predict VO2peak. PMID:25068750

  14. Second-generation antipsychotics cause a rapid switch to fat oxidation that is required for survival in C57BL/6J mice.

    PubMed

    Klingerman, Candice M; Stipanovic, Michelle E; Bader, Mohammad; Lynch, Christopher J

    2014-03-01

    Some second-generation antipsychotics (SGAs) increase insulin resistance and fat oxidation, but counter intuitively they do not activate lipolysis. This seems unsustainable for meeting energy demands. Here, we measured dose-dependent effects of SGAs on rates of oxygen consumption (VO2), respiratory exchange ratio (RER), and physical activity in C57BL/6J mice. The role of H1-histamine receptors and consequences of blocking fat oxidation were also examined. Olanzapine, risperidone, and clozapine (2.5-10mg/kg) elicited rapid drops in dark-cycle RER (~0.7) within minutes, whereas aripiprazole exerted only modest changes. Higher doses of olanzapine decreased VO2, and this was associated with accumulation of glucose in plasma. Clozapine and risperidone also lowered VO2, in contrast to aripiprazole, whereas all decreased physical activity. Astemizole and terfenadine had no significant effects on RER, VO2, or physical activity. The VO2 and RER effects appear independent of sedation/physical activity or H1-receptors. CPT-1 inhibitors can enhance muscle glucose utilization and prevent fat oxidation. However, after etomoxir (2 × 30 mg/kg), a low dose of olanzapine that did not significantly affect VO2 by itself caused precipitous drops in VO2 and body temperature, leading to death within hours or a moribund state requiring euthanasia. One 30 mg/kg dose of either etomoxir or 2-tetradecylglycidate followed by olanzapine, risperidone, or clozapine, but not aripiprazole, dramatically lowered VO2 and body temperature. Thus, mice treated with some SGAs shift their fuel utilization to mostly fat but are unable to either switch back to glucose or meet their energy demands when either higher doses are used or when fat oxidation is blocked.

  15. Second-Generation Antipsychotics Cause a Rapid Switch to Fat Oxidation That Is Required for Survival in C57BL/6J Mice

    PubMed Central

    Lynch, Christopher J.

    2014-01-01

    Some second-generation antipsychotics (SGAs) increase insulin resistance and fat oxidation, but counter intuitively they do not activate lipolysis. This seems unsustainable for meeting energy demands. Here, we measured dose-dependent effects of SGAs on rates of oxygen consumption (VO2), respiratory exchange ratio (RER), and physical activity in C57BL/6J mice. The role of H1-histamine receptors and consequences of blocking fat oxidation were also examined. Olanzapine, risperidone, and clozapine (2.5–10mg/kg) elicited rapid drops in dark-cycle RER (~0.7) within minutes, whereas aripiprazole exerted only modest changes. Higher doses of olanzapine decreased VO2, and this was associated with accumulation of glucose in plasma. Clozapine and risperidone also lowered VO2, in contrast to aripiprazole, whereas all decreased physical activity. Astemizole and terfenadine had no significant effects on RER, VO2, or physical activity. The VO2 and RER effects appear independent of sedation/physical activity or H1-receptors. CPT-1 inhibitors can enhance muscle glucose utilization and prevent fat oxidation. However, after etomoxir (2 × 30mg/kg), a low dose of olanzapine that did not significantly affect VO2 by itself caused precipitous drops in VO2 and body temperature, leading to death within hours or a moribund state requiring euthanasia. One 30mg/kg dose of either etomoxir or 2-tetradecylglycidate followed by olanzapine, risperidone, or clozapine, but not aripiprazole, dramatically lowered VO2 and body temperature. Thus, mice treated with some SGAs shift their fuel utilization to mostly fat but are unable to either switch back to glucose or meet their energy demands when either higher doses are used or when fat oxidation is blocked. PMID:23328157

  16. Peak Exercise Oxygen Uptake Predicts Recurrent Admissions in Heart Failure With Preserved Ejection Fraction.

    PubMed

    Palau, Patricia; Domínguez, Eloy; Núñez, Eduardo; Ramón, José María; López, Laura; Melero, Joana; Sanchis, Juan; Bellver, Alejandro; Santas, Enrique; Bayes-Genis, Antoni; Chorro, Francisco J; Núñez, Julio

    2018-04-01

    Heart failure with preserved ejection fraction (HFpEF) is a highly prevalent syndrome with an elevated risk of morbidity and mortality. To date, there is scarce evidence on the role of peak exercise oxygen uptake (peak VO 2 ) for predicting the morbidity burden in HFpEF. We sought to evaluate the association between peak VO 2 and the risk of recurrent hospitalizations in patients with HFpEF. A total of 74 stable symptomatic patients with HFpEF underwent a cardiopulmonary exercise test between June 2012 and May 2016. A negative binomial regression method was used to determine the association between the percentage of predicted peak VO 2 (pp-peak VO 2 ) and recurrent hospitalizations. Risk estimates are reported as incidence rate ratios. The mean age was 72.5 ± 9.1 years, 53% were women, and all patients were in New York Heart Association functional class II to III. Mean peak VO 2 and median pp-peak VO 2 were 10 ± 2.8mL/min/kg and 60% (range, 47-67), respectively. During a median follow-up of 276 days [interquartile range, 153-1231], 84 all-cause hospitalizations in 31 patients (41.9%) were registered. A total of 15 (20.3%) deaths were also recorded. On multivariate analysis, accounting for mortality as a terminal event, pp-peak VO 2 was independently and linearly associated with the risk of recurrent admission. Thus, and modeled as continuous, a 10% decrease of pp-peak VO 2 increased the risk of recurrent hospitalizations by 32% (IRR, 1.32; 95%CI, 1.03-1.68; P = .028). In symptomatic elderly patients with HFpEF, pp-peak VO 2 predicts all-cause recurrent admission. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  17. Visual Impairment does not Limit Training Effects in Development of Aerobic and Anaerobic Capacity in Tandem Cyclists

    PubMed Central

    Malwina, Kamelska Anna; Krzysztof, Mazurek; Piotr, Zmijewski

    2015-01-01

    The study aimed to investigate the differences in the effects of 7-month training on aerobic and anaerobic capacity in tandem cycling athletes with and without visual impairment. In this study, Polish elite (n=13) and sub-elite (n=13) visually impaired (VI) (n=13; 40.8 ±12.8 years) and properly sighted (PS) (n=13; 36.7 ±12.2 years) tandem-cycling athletes participated voluntarily in 7-month routine training. The following pre-/post-training measurements were conducted on separate days: maximal oxygen uptake (VO2max) was estimated with age correction using the Physical Working Capacity test on a bicycle ergometer according to the Astrand-Ryhming method. Maximal power output (Pmax) was evaluated using the Quebec test on a bicycle ergometer. At baseline, VO2max (47.8 ±14.1 vs 42.0 ±8.3 ml/kg/min, respectively) and Pmax (11.5 ±1.5 vs 11.5 ±1.0 W/kg) did not differ significantly between PS and VI cyclists. However, differences in aerobic capacity were considered as clinically significant. Two-way ANOVA revealed that after 7 month training, there were statistically significant increases in VO2max (p=0.003) and Pmax (p=0.009) among VI (VO2max, +9.1%; Pmax, +6.3%) and PS (VO2max, +9.1%; Pmax, +11.7%) cyclists, however, no time × visual impairment interaction effect was found (VO2max, p=0.467; Pmax, p=0.364). After training, VO2max (p=0.03), but not Pmax (p=0.13), was significantly greater in elite compared to sub-elite tandem cyclists. VI and PS tandem cyclists showed similar rates of improvement in VO2max and Pmax after 7-month training. VO2max was a significant determinant of success in tandem cycling. This is one of the first studies providing reference values for aerobic and anaerobic capacity in visually impaired cyclists. PMID:26834877

  18. Validation of the firefighter WFI treadmill protocol for predicting VO2 max.

    PubMed

    Dolezal, B A; Barr, D; Boland, D M; Smith, D L; Cooper, C B

    2015-03-01

    The Wellness-Fitness Initiative submaximal treadmill exercise test (WFI-TM) is recommended by the US National Fire Protection Agency to assess aerobic capacity (VO2 max) in firefighters. However, predicting VO2 max from submaximal tests can result in errors leading to erroneous conclusions about fitness. To investigate the level of agreement between VO2 max predicted from the WFI-TM against its direct measurement using exhaled gas analysis. The WFI-TM was performed to volitional fatigue. Differences between estimated VO2 max (derived from the WFI-TM equation) and direct measurement (exhaled gas analysis) were compared by paired t-test and agreement was determined using Pearson Product-Moment correlation and Bland-Altman analysis. Statistical significance was set at P < 0.05. Fifty-nine men performed the WFI-TM. Mean (standard deviation) values for estimated and measured VO2 max were 44.6 (3.4) and 43.6 (7.9) ml/kg/min, respectively (P < 0.01). The mean bias by which WFI-TM overestimated VO2 max was 0.9ml/kg/min with a 95% prediction interval of ±13.1. Prediction errors for 22% of subjects were within ±5%; 36% had errors greater than or equal to ±15% and 7% had greater than ±30% errors. The correlation between predicted and measured VO2 max was r = 0.55 (standard error of the estimate = 2.8ml/kg/min). WFI-TM predicts VO2 max with 11% error. There is a tendency to overestimate aerobic capacity in less fit individuals and to underestimate it in more fit individuals leading to a clustering of values around 42ml/kg/min, a criterion used by some fire departments to assess fitness for duty. © The Author 2015. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Fourier transform infrared study of the phase transitions in (NH4)3VO2FO4

    NASA Astrophysics Data System (ADS)

    de Waal, D.; Heyns, A. M.

    1994-01-01

    Ammonium oxofluorovanadate compounds are known to show some potential as ferroelectric materials. The whole series of ammonium and sodium oxofluorovanadate compounds including Na3VO2F4 have already been prepared and investigated by means of various techniques including x-ray diffraction, EPR, and vibrational spectroscopy. It was established that the pure ammonium compound shows the two above mentioned transitions from phase A (below 200 K) to phase B (between 200 and 400 K) and phase C (above 400 K) while Na(NH4)2VO2F4 has only one transition from phase A to phase B around 400 K4. In the present study various aspects regarding the nature of the structures of (NH4)3VO2F3 and Na(NH4)2VO2F4 and its influence on the phase transitions have been investigated.

  20. In situ probing of doping- and stress-mediated phase transitions in a single-crystalline VO2 nanobeam by spatially resolved Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Chang, Sung-Jin; Park, Jong Bae; Lee, Gaehang; Kim, Hae Jin; Lee, Jin-Bae; Bae, Tae-Sung; Han, Young-Kyu; Park, Tae Jung; Huh, Yun Suk; Hong, Woong-Ki

    2014-06-01

    We demonstrate an experimental in situ observation of the temperature-dependent evolution of doping- and stress-mediated structural phase transitions in an individual single-crystalline VO2 nanobeam on a Au-coated substrate under exposure to hydrogen gas using spatially resolved Raman spectroscopy. The nucleation temperature of the rutile R structural phase in the VO2 nanobeam upon heating under hydrogen gas was lower than that under air. The spatial structural phase evolution behavior along the length of the VO2 nanobeam under hydrogen gas upon heating was much more inhomogeneous than that along the length of the same nanobeam under air. The triclinic T phase of the VO2 nanobeam upon heating under hydrogen gas transformed to the R phase and this R phase was stabilized even at room temperature in air after sample cooling. In particular, after the VO2 nanobeam with the R phase was annealed at approximately 250 °C in air, it exhibited the monoclinic M1 phase (not the T phase) at room temperature during heating and cooling cycles. These results were attributed to the interplay between hydrogen doping and stress associated with nanobeam-substrate interactions. Our study has important implications for engineering metal-insulator transition properties and developing functional devices based on VO2 nanostructures through doping and stress.We demonstrate an experimental in situ observation of the temperature-dependent evolution of doping- and stress-mediated structural phase transitions in an individual single-crystalline VO2 nanobeam on a Au-coated substrate under exposure to hydrogen gas using spatially resolved Raman spectroscopy. The nucleation temperature of the rutile R structural phase in the VO2 nanobeam upon heating under hydrogen gas was lower than that under air. The spatial structural phase evolution behavior along the length of the VO2 nanobeam under hydrogen gas upon heating was much more inhomogeneous than that along the length of the same nanobeam under air. The triclinic T phase of the VO2 nanobeam upon heating under hydrogen gas transformed to the R phase and this R phase was stabilized even at room temperature in air after sample cooling. In particular, after the VO2 nanobeam with the R phase was annealed at approximately 250 °C in air, it exhibited the monoclinic M1 phase (not the T phase) at room temperature during heating and cooling cycles. These results were attributed to the interplay between hydrogen doping and stress associated with nanobeam-substrate interactions. Our study has important implications for engineering metal-insulator transition properties and developing functional devices based on VO2 nanostructures through doping and stress. Electronic supplementary information (ESI) available: Illustration, photograph, Raman data, and EDX spectra. See DOI: 10.1039/c4nr01118j

  1. Controlled synthesis of Ag{sub 3}PO{sub 4}/BiVO{sub 4} composites with enhanced visible-light photocatalytic performance for the degradation of RhB and 2, 4-DCP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qi, Xuemei; School of Environmental and Chemical Engineering, Shanghai University of Electric Power, Shanghai 200090; Gu, Miaoli

    Highlights: • Ag{sub 3}PO{sub 4}/BiVO{sub 4} composites were synthesized by in-situ precipitation method. • Ag{sub 3}PO{sub 4}/BiVO{sub 4} is more efficient than pure Ag{sub 3}PO{sub 4} and BiVO{sub 4} for RhB and 2, 4-DCP degradation. • Ag{sub 3}PO{sub 4}/BiVO{sub 4} can act as a high performance and low cost photocatalyst. - Abstract: Ag{sub 3}PO{sub 4}/BiVO{sub 4} composites were fabricated by in-situ precipitation method. Results showed that Ag{sub 3}PO{sub 4}/BiVO{sub 4} composites exhibited higher photocatalytic activity than that of pure BiVO{sub 4} and Ag{sub 3}PO{sub 4} sample under visible light irradiation. The effect of Ag{sub 3}PO{sub 4}:BiVO{sub 4} ratio on themore » photocatalytic activity was systemically studied and the optimum molar ratio of Ag{sub 3}PO{sub 4}:BiVO{sub 4} was 1:5. The Ag{sub 3}PO{sub 4}/BiVO{sub 4}-5 exhibited excellent photocatalytic activity for the degradation of Rhodamine B (ca. 92% in 30 min) and 2, 4-dichlorophenol (ca. 84% in 180 min) under visible light irradiation. The enhanced photocatalytic activity could be mainly ascribed to the suitable Ag{sub 3}PO{sub 4}/BiVO{sub 4} heterojunction interface and the smaller particles of Ag{sub 3}PO{sub 4} compared to pure Ag{sub 3}PO{sub 4} particles which could promote the separation of photoinduced electron-hole pairs. The Ag{sub 3}PO{sub 4}/BiVO{sub 4} composite can significantly reduce the silver consumption compared to the pure Ag{sub 3}PO{sub 4}. It is worth noting that Ag{sub 3}PO{sub 4}/BiVO{sub 4} composite can act as a high performance and low cost visible-light-driven photocatalyst for environmental remediation.« less

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Eryong, E-mail: ley401@163.com; State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000; Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201

    Silver vanadate (AgVO{sub 3}) nanowires were synthesized by hydrothermal method and self-lubricating NiAl/Mo-AgVO{sub 3} composites were fabricated by powder metallurgy technique. The composition and microstructure of NiAl/Mo-based composites were characterized and the tribological properties were investigated from room temperature to 900 °C. The results showed that NiAl/Mo-based composites were consisted of nanocrystalline B2 ordered NiAl matrix, Al{sub 2}O{sub 3}, Mo{sub 2}C, metallic Ag and vanadium oxide phase. The appearance of metallic Ag and vanadium oxide phase can be attributed to the decomposition of AgVO{sub 3} during sintering. Wear testing results confirmed that NiAl/Mo-based composites have excellent tribological properties over amore » wide temperature range. For example, the friction coefficient and wear rate of NiAl/Mo-based composites containing AgVO{sub 3} were significantly lower than the composites containing only metallic Mo or AgVO{sub 3} lubricant when the temperature is above 300 °C, which can be attributed to the synergistic lubricating action of metallic Mo and AgVO{sub 3} lubricants. Furthermore, Raman results indicated that the composition on the worn surface of NiAl-based composites was self-adjusted after wear testing at different temperatures. For example, Ag{sub 3}VO{sub 4} and Fe{sub 3}O{sub 4} lubricants were responsible for the improvement of tribological properties at 500 °C, AgVO{sub 3}, Ag{sub 3}VO{sub 4} and molybdate for 700 °C, and AgVO{sub 3} and molybdate for 900 °C of NiAl-based composites with the addition of metallic Mo and AgVO{sub 3}. - Highlights: • NiAl/Mo-AgVO{sub 3} nanocomposites were prepared by mechanical alloying and sintering. • AgVO{sub 3} decomposed to metallic Ag and vanadium oxide during the sintering process. • NiAl/Mo-AgVO{sub 3} exhibited superior tribological properties at a board temperature range. • Phase composition on the worn surface was varied with temperatures. • Self-adjusted action was responsible for the improvement of tribological properties.« less

  3. Tunable Picosecond Laser Pulses via the Contrast of Two Reverse Saturable Absorption Phases in a Waveguide Platform

    PubMed Central

    Tan, Yang; Chen, Lianwei; Wang, Dong; Chen, Yanxue; Akhmadaliev, Shavkat; Zhou, Shengqiang; Hong, Minghui; Chen, Feng

    2016-01-01

    How to enhance the optical nonlinearity of saturable absorption materials is an important question to improve the functionality of various applications ranging from the high power laser to photonic computational devices. We demonstrate the saturable absorption (SA) of VO2 film attributed to the large difference of optical nonlinearities between the two states of the phase-transition materials (VO2). Such VO2 film demonstrated significantly improved performance with saturation intensity higher than other existing ultrathin saturable absorbers by 3 orders due to its unique nonlinear optical mechanisms in the ultrafast phase change process. Owing to this feature, a Q-switched pulsed laser was fabricated in a waveguide platform, which is the first time to achieve picosecond pulse duration and maintain high peak power. Furthermore, the emission of this VO2 waveguide laser can be flexibly switched between the continuous-wave (CW) and pulsed operation regimes by tuning the temperature of the VO2 film, which enables VO2-based miniature laser devices with unique and versatile functions. PMID:27188594

  4. Metal-insulator transition of valence-controlled VO2 thin film prepared by RF magnetron sputtering using oxygen radical

    NASA Astrophysics Data System (ADS)

    Suetsugu, Takaaki; Shimazu, Yuichi; Tsuchiya, Takashi; Kobayashi, Masaki; Minohara, Makoto; Sakai, Enju; Horiba, Koji; Kumigashira, Hiroshi; Higuchi, Tohru

    2016-06-01

    We have prepared b-axis-oriented VO2 thin films by RF magnetron sputtering using oxygen radicals as the reactive gas. The VO2 thin films consist of a mixed-valence V3+/V4+ state formed by oxygen vacancies. The V3+ ratio strongly depends on the film thickness and the oxygen partial pressure of the radical gun during deposition. The lattice constant of the b-axis increases and the metal-insulator transition (MIT) temperature decreases with decreasing V3+ ratio, although the VO2 thin films with a high V3+ ratio of 42% do not exhibit MIT. The bandwidths and spectral weights of V 3d a1g and \\text{e}\\text{g}σ bands at around the Fermi level, which correspond to the insulating phase at 300 K, are smaller in the VO2 thin films with a low V3+ ratio. These results indicate that the control of the mixed-valence V3+/V4+ state is important for the MIT of b-axis-oriented VO2 thin films.

  5. Investigations on structural and giant magneto impedance properties of Zn3(VO4)2 nanorods

    NASA Astrophysics Data System (ADS)

    Malaidurai, M.; Bulusu, Venkat; De, Sourodeep; Thangavel, R.

    2018-05-01

    In this paper, we successfully synthesized Zn3(VO4)2 novel nanorods by hydrothermal method. As mixed phase of Zn3(VO4)2 structural and phase transformations were monitored in crystal lattice with different ionic strength by X-ray diffraction(XRD). The Zn3(VO4)2 thin film formation validated through qualitative and quantitative analysis by FESEM and it is clearly depicted the formation of the Zn3(VO4)2 nanorods varied from ˜100nm in lengths and ˜30 nm in widths. The Zn precursor's anions directly influence the composition and shape of the resultant hydrated Zn3(VO4)2. Impedance analysis were closely studied with Impedance-Frequency characterization, which was then followed by a dielectric measurement. The analysis of GMI effect was carried out with the help of the model equivalent circuit at low frequencies, constant phase element (CPE). GMI effect and the sensitivity are calculated for the sample by appling magnetic field and driving frequency in order to analyze the giant magnetoimpedance resistance of grain boundaries for spintronics applications.

  6. Variability of prediction of maximal oxygen concumption on the cycle ergometer using standard equations

    NASA Technical Reports Server (NTRS)

    Greenisen, Michael C.; Fortney, Suzanne M.; Lee, Stuart M. C.; Moore, Alan D.; Barrows, Linda H.

    1993-01-01

    Several investigations within the Exercise Countermeasures Project at the NASA Johnson Space Center focused on the assessment of maximum oxygen consumption (VO2(sub max)) within the Astronaut Corps pre- and postspace flight. Investigations during the Apollo era suggested that there was a significant decrease in postflight VO2(sub max) when compared to preflight values, and current studies have documented that this trend continues in the Space Shuttle era. It is generally accepted and was confirmed in our laboratory that VO2(sub max) can be predicted from submaximal measures taken during graded exercise tests on the cycle ergometer with respect to populations. However, previous work had not examined the effect of day-to-day variations in the physiologic responses that might alter these predictions for individuals. Stability of individual submaximal data over serial tests is important so that predicted changes in VO2(sub max) are reflective of actual VO2(sub max) changes. Therefore, the purpose of this investigation was to determine which of the accepted equations to predict VO2(sub max) would be less affected by normal daily physiologic changes.

  7. Changes in blood lactate and respiratory gas exchange measures in sports with discontinuous load profiles.

    PubMed

    Smekal, Gerhard; von Duvillard, Serge P; Pokan, Rochus; Tschan, Harald; Baron, Ramon; Hofmann, Peter; Wonisch, Manfred; Bachl, Norbert

    2003-06-01

    This study compares two different sport events (orienteering = OTC; tennis = TEC) with discontinuous load profiles and different activity/recovery patterns by means of blood lactate (LA), heart rate (HR), and respiratory gas exchange measures (RGME) determined via a portable respiratory system. During the TEC, 20 tennis-ranked male subjects [age: 26.0 (3.7) years; height: 181.0 (5.7) cm; weight: 73.2 (6.8) kg; maximal oxygen consumption (VO(2)max): 57.3 (5.1) ml.kg(-1).min(-1)] played ten matches of 50 min. During the OTC, 11 male members of the Austrian National Team [age: 23.5 (3.9) years; height: 183.6 (6.8) cm; weight: 72.4 (3.9) kg; VO(2)max: 67.9 (3.8) ml.kg(-1).min(-1)] performed a simulated OTC (six sections; average length: 10.090 m). In both studies data from the maximal treadmill tests (TT) were used as reference values for the comparison of energy expenditure of OTC and TEC. During TEC, the average VO(2) was considerably lower [29.1 (5.6) ml(.)kg(-1.)min(-1)] or 51.1 (10.9)% of VO(2)max and 64.8.0 (13.3)% of VO(2) determined at the individual anaerobic threshold (IAT) on the TT. The short high-intensity periods (activity/recovery = 1/6) did not result in higher LA levels [average LA of games: 2.07 (0.9) mmol.l(-1)]. The highest average VO(2 )value for a whole game was 47.8 ml.kg(-1.)min(-1) and may provide a reference for energy demands required to sustain high-intensity periods of tennis predominantly via aerobic mechanism of energy delivery. During OTC, we found an average VO(2) of 56.4 (4.5) ml.kg(-1).min(-1) or 83.0 (3.8)% of VO(2)max and 94.6 (5.2)% of VO(2) at IAT. In contrast to TEC, LA were relatively high [5.16 (1.5) mmol.l(-1)) although the average VO(2) was significantly lower than VO(2) at IAT. Our data suggest that portable RGEM provides valuable information concerning the energy expenditure in sports that cannot be interpreted from LA or HR measures alone. Portable RGEM systems provide valuable assessment of under- or over-estimation of requirements of sports and assist in the optimization and interpretation of training in athletes.

  8. Validation of one-mile walk equations for the estimation of aerobic fitness in British military personnel under the age of 40 years.

    PubMed

    Lunt, Heather; Roiz De Sa, Daniel; Roiz De Sa, Julia; Allsopp, Adrian

    2013-07-01

    To provide an accurate estimate of peak oxygen uptake (VO2 peak) for British Royal Navy Personnel aged between 18 and 39, comparing a gold standard treadmill based maximal exercise test with a submaximal one-mile walk test. Two hundred military personnel consented to perform a treadmill-based VO2 peak test and two one-mile walk tests round an athletics track. The estimated VO2 peak values from three different one-mile walk equations were compared to directly measured VO2 peak values from the treadmill-based test. One hundred participants formed a validation group from which a new equation was derived and the other 100 participants formed the cross-validation group. Existing equations underestimated the VO2 peak values of the fittest personnel and overestimated the VO2 peak of the least aerobically fit by between 2% and 18%. The new equation derived from the validation group has less bias, the highest correlation with the measured values (r = 0.83), and classified the most people correctly according to the Royal Navy's Fitness Test standards, producing the fewest false positives and false negatives combined (9%). The new equation will provide a more accurate estimate of VO2 peak for a British military population aged 18 to 39. Reprint & Copyright © 2013 Association of Military Surgeons of the U.S.

  9. Decoupling the Lattice Distortion and Charge Doping Effects on the Phase Transition Behavior of VO2 by Titanium (Ti4+) Doping

    PubMed Central

    Wu, Yanfei; Fan, Lele; Liu, Qinghua; Chen, Shi; Huang, Weifeng; Chen, Feihu; Liao, Guangming; Zou, Chongwen; Wu, Ziyu

    2015-01-01

    The mechanism for regulating the critical temperature (TC) of metal-insulator transition (MIT) in ions-doped VO2 systems is still a matter of debate, in particular, the unclear roles of lattice distortion and charge doping effects. To rule out the charge doping effect on the regulation of TC, we investigated Ti4+-doped VO2 (TixV1-xO2) system. It was observed that the TC of TixV1-xO2 samples first slightly decreased and then increased with increasing Ti concentration. X-ray absorption fine structure (XAFS) spectroscopy was used to explore the electronic states and local lattice structures around both Ti and V atoms in TixV1-xO2 samples. Our results revealed the local structure evolution from the initial anatase to the rutile-like structure around the Ti dopants. Furthermore, the host monoclinic VO2 lattice, specifically, the VO6 octahedra would be subtly distorted by Ti doping. The distortion of VO6 octahedra and the variation of TC showed almost the similar trend, confirming the direct effect of local structural perturbations on the phase transition behavior. By comparing other ion-doping systems, we point out that the charge doping is more effective than the lattice distortion in modulating the MIT behavior of VO2 materials. PMID:25950809

  10. Oxygen consumption is depressed in patients with lactic acidosis due to biguanide intoxication.

    PubMed

    Protti, Alessandro; Russo, Riccarda; Tagliabue, Paola; Vecchio, Sarah; Singer, Mervyn; Rudiger, Alain; Foti, Giuseppe; Rossi, Anna; Mistraletti, Giovanni; Gattinoni, Luciano

    2010-01-01

    Lactic acidosis can develop during biguanide (metformin and phenformin) intoxication, possibly as a consequence of mitochondrial dysfunction. To verify this hypothesis, we investigated whether body oxygen consumption (VO2), that primarily depends on mitochondrial respiration, is depressed in patients with biguanide intoxication. Multicentre retrospective analysis of data collected from 24 patients with lactic acidosis (pH 6.93 +/- 0.20; lactate 18 +/- 6 mM at hospital admission) due to metformin (n = 23) or phenformin (n = 1) intoxication. In 11 patients, VO2 was computed as the product of simultaneously recorded arterio-venous difference in O2 content [C(a-v)O2] and cardiac index (CI). In 13 additional cases, C(a-v)O2, but not CI, was available. On day 1, VO2 was markedly depressed (67 +/- 28 ml/min/m2) despite a normal CI (3.4 +/- 1.2 L/min/m2). C(a-v)O2 was abnormally low in both patients either with (2.0 +/- 1.0 ml O2/100 ml) or without (2.5 +/- 1.1 ml O2/100 ml) CI (and VO2) monitoring. Clearance of the accumulated drug was associated with the resolution of lactic acidosis and a parallel increase in VO2 (P < 0.001) and C(a-v)O2 (P < 0.05). Plasma lactate and VO2 were inversely correlated (R2 0.43; P < 0.001, n = 32). VO2 is abnormally low in patients with lactic acidosis due to biguanide intoxication. This finding is in line with the hypothesis of inhibited mitochondrial respiration and consequent hyperlactatemia.

  11. Understanding bactericidal performance on ambient light activated TiO2-InVO4 nanostructured films.

    PubMed

    He, Ziming; Xu, Qingchi; Tan, Timothy Thatt Yang

    2011-12-01

    TiO(2)-InVO(4) nanostructured films were coated onto glass substrates and systematically investigated for their bactericidal activities using Escherichia coli (E. coli) as the model bacterium under ambient light illumination. The uniform TiO(2)-InVO(4) nanostructured films were prepared using titanium isopropoxide (TTIP) as the precursor via a simple sol-gel approach. Polyethylenimine (PEI) was used as a surfactant to ensure uniform dispersion of InVO(4) and a sacrificial pore-inducing agent, generating nanostructured films. Compared to unmodified TiO(2) film, the current TiO(2)-InVO(4) films exhibited enhanced bactericidal activities under ambient light illumination. Bacterial cell "photo-fixation" was demonstrated to be crucial in enhancing the bactericidal activity. A bacterial-nanostructured surface interaction mechanism was proposed for the current ambient-light activated nanostructured film.

  12. Frequency tunable near-infrared metamaterials based on VO2 phase transition.

    PubMed

    Dicken, Matthew J; Aydin, Koray; Pryce, Imogen M; Sweatlock, Luke A; Boyd, Elizabeth M; Walavalkar, Sameer; Ma, James; Atwater, Harry A

    2009-09-28

    Engineering metamaterials with tunable resonances from mid-infrared to near-infrared wavelengths could have far-reaching consequences for chip based optical devices, active filters, modulators, and sensors. Utilizing the metal-insulator phase transition in vanadium oxide (VO(2)), we demonstrate frequency-tunable metamaterials in the near-IR range, from 1.5 - 5 microns. Arrays of Ag split ring resonators (SRRs) are patterned with e-beam lithography onto planar VO(2) and etched via reactive ion etching to yield Ag/VO(2) hybrid SRRs. FTIR reflection data and FDTD simulation results show the resonant peak position red shifts upon heating above the phase transition temperature. We also show that, by including coupling elements in the design of these hybrid Ag/VO(2) bi-layer structures, we can achieve resonant peak position tuning of up to 110 nm.

  13. Allometric modelling of peak oxygen uptake in male soccer players of 8-18 years of age.

    PubMed

    Valente-Dos-Santos, João; Coelho-E-Silva, Manuel J; Tavares, Óscar M; Brito, João; Seabra, André; Rebelo, António; Sherar, Lauren B; Elferink-Gemser, Marije T; Malina, Robert M

    2015-03-01

    Peak oxygen uptake (VO2peak) is routinely scaled as mL O2 per kilogram body mass despite theoretical and statistical limitations of using ratios. To examine the contribution of maturity status and body size descriptors to age-associated inter-individual variability in VO2peak and to present static allometric models to normalize VO2peak in male youth soccer players. Total body and estimates of total and regional lean mass were measured with dual energy X-ray absorptiometry in a cross-sectional sample of Portuguese male soccer players. The sample was divided into three age groups for analysis: 8-12 years, 13-15 years and 16-18 years. VO2peak was estimated using an incremental maximal exercise test on a motorized treadmill. Static allometric models were used to normalize VO2peak. The independent variables with the best statistical fit explained 72% in the younger group (lean body mass: k = 1.07), 52% in mid-adolescent players (lean body mass: k = 0.93) and 31% in the older group (body mass: k = 0.51) of variance in VO2peak. The inclusion of the exponential term pubertal status marginally increased the explained variance in VO2peak (adjusted R(2 )= 36-75%) and provided statistical adjustments to the size descriptors coefficients. The allometric coefficients and exponents evidenced the varying inter-relationship among size descriptors and maturity status with aerobic fitness from early to late-adolescence. Lean body mass, lean lower limbs mass and body mass combined with pubertal status explain most of the inter-individual variability in VO2peak among youth soccer players.

  14. Theoretical studies of the low-lying states of ScO, ScS, VO, and VS

    NASA Technical Reports Server (NTRS)

    Bauschlicher, Charles W., Jr.; Langhoff, Stephen R.

    1986-01-01

    Bonding in the low-lying states of ScO, ScS, VO, and VS is theoretically studied. Excellent agreement is obtained with experimental spectroscopic constants for the low-lying states of ScO and VO. The results for VS and ScS show that the bonding in the oxides and sulfides is similar, but that the smaller electronegativity in S leads to a smaller ionic component in the bonding. The computed D0 of the sulfides are about 86 percent of the corresponding oxides, and the low-lying excited states are lower in the sulfides than in the corresponding oxides. The CPF method is shown to be an accurate and cost-effective method for obtaining reliable spectroscopic constants for these systems.

  15. Multilayer Ni/Fe thin films as oxygen evolution catalysts for solar fuel production

    NASA Astrophysics Data System (ADS)

    Biset-Peiró, M.; Murcia-López, S.; Fàbrega, C.; Morante, J. R.; Andreu, T.

    2017-03-01

    The slow kinetics and high overpotential of the oxygen evolution reaction is one of the main limiting factors to achieve the minimum required performances of the so-called photoelectrochemical water splitting systems. An oxygen evolution catalyst (OEC) becomes essential in order to perform this process with higher efficiency. Herein, we report the physical, optical and electrochemical characterization of multilayer Ni/Fe thin films as earth-abundant OEC, to avoid the use of platinum group metals (PGM). Uniform films of thicknesses ranging from 1 to 10 nm were fabricated by sequential and alternate thermal evaporation of Ni and Fe. It was found that the successive deposition allows the fabrication of a Ni terminated surface that does not need activation due to the Fe underlayer. The lowest overpotential achieved for NiFe was 370 mV at 10 mA cm-2 and a Tafel slope of 37 mV dec-1 with 1 nm thickness and 95% transmittance. Finally, NiFe OEC was implemented on top of Mo:BiVO4 photoanodes which resulted in a reduction of the open circuit potential of 0.2 V and up to five fold increase of the oxidation efficiency at 0.7 VRHE. The results presented facilitate the practical implementation of BiVO4 photoanodes in tandem configuration for bias free photoassisted water splitting.

  16. BiVO4 thin film photoanodes grown by chemical vapor deposition.

    PubMed

    Alarcón-Lladó, Esther; Chen, Le; Hettick, Mark; Mashouf, Neeka; Lin, Yongjing; Javey, Ali; Ager, Joel W

    2014-01-28

    BiVO4 thin film photoanodes were grown by vapor transport chemical deposition on FTO/glass substrates. By controlling the flow rate, the temperatures of the Bi and V sources (Bi metal and V2O5 powder, respectively), and the temperature of the deposition zone in a two-zone furnace, single-phase monoclinic BiVO4 thin films can be obtained. The CVD-grown films produce global AM1.5 photocurrent densities up to 1 mA cm(-2) in aqueous conditions in the presence of a sacrificial reagent. Front illuminated photocatalytic performance can be improved by inserting either a SnO2 hole blocking layer and/or a thin, extrinsically Mo doped BiVO4 layer between the FTO and the CVD-grown layer. The incident photon to current efficiency (IPCE), measured under front illumination, for BiVO4 grown directly on FTO/glass is about 10% for wavelengths below 450 nm at a bias of +0.6 V vs. Ag/AgCl. For BiVO4 grown on a 40 nm SnO2/20 nm Mo-doped BiVO4 back contact, the IPCE is increased to over 40% at wavelengths below 420 nm.

  17. Production and evolution of A-centers in n-type Si1-xGex

    NASA Astrophysics Data System (ADS)

    Sgourou, E. N.; Andrianakis, A.; Londos, C. A.; Chroneos, A.

    2013-03-01

    The vacancy-oxygen pair (VO or A-center) in n-type Si1-xGex crystals (x = 0, 0.025, 0.055) has been studied using infrared (IR) spectroscopy. It is determined that the VO production is suppressed in the case of n-type Si1-xGex as compared to Si. It is observed that the annealing temperature of the VO defect in Si1-xGex is substantially lower as compared to Si. The decay of the VO (830 cm-1) band, in the course of 20 min isochronal anneals, shows two stages: The onset of the first stage is at ˜180 °C and the decrease of the VO signal is accompanied in the spectra by the increase of the intensity of two bands at ˜834 and 839 cm-1. These bands appear in the spectra immediately after irradiation and were previously correlated with (VO-Ge) structures. The onset of the second stage occurs at ˜250 °C were the 830 cm-1 band of VO and the above two bands of (VO-Ge) decrease together in the spectra accompanied by the simultaneous growth of the 885 cm-1 band of the VO2 defect. Interestingly, the percentage of the VO pairs that are converted to VO2 defects is larger in the Si1-xGex samples with intermediate Ge content (x = 0.025) as compared with Si (x = 0) and with the high Ge content samples (x = 0.055). The results are discussed in view of the association of VO pairs with Ge.

  18. Cardiovascular consequences of bed rest: effect on maximal oxygen uptake

    NASA Technical Reports Server (NTRS)

    Convertino, V. A.

    1997-01-01

    Maximal oxygen uptake (VO2max) is reduced in healthy individuals confined to bed rest, suggesting it is independent of any disease state. The magnitude of reduction in VO2max is dependent on duration of bed rest and the initial level of aerobic fitness (VO2max), but it appears to be independent of age or gender. Bed rest induces an elevated maximal heart rate which, in turn, is associated with decreased cardiac vagal tone, increased sympathetic catecholamine secretion, and greater cardiac beta-receptor sensitivity. Despite the elevation in heart rate, VO2max is reduced primarily from decreased maximal stroke volume and cardiac output. An elevated ejection fraction during exercise following bed rest suggests that the lower stroke volume is not caused by ventricular dysfunction but is primarily the result of decreased venous return associated with lower circulating blood volume, reduced central venous pressure, and higher venous compliance in the lower extremities. VO2max, stroke volume, and cardiac output are further compromised by exercise in the upright posture. The contribution of hypovolemia to reduced cardiac output during exercise following bed rest is supported by the close relationship between the relative magnitude (% delta) and time course of change in blood volume and VO2max during bed rest, and also by the fact that retention of plasma volume is associated with maintenance of VO2max after bed rest. Arteriovenous oxygen difference during maximal exercise is not altered by bed rest, suggesting that peripheral mechanisms may not contribute significantly to the decreased VO2max. However reduction in baseline and maximal muscle blood flow, red blood cell volume, and capillarization in working muscles represent peripheral mechanisms that may contribute to limited oxygen delivery and, subsequently, lowered VO2max. Thus, alterations in cardiac and vascular functions induced by prolonged confinement to bed rest contribute to diminution of maximal oxygen uptake and reserve capacity to perform physical work.

  19. Motor competence and cardiorespiratory fitness have greater influence on body fatness than physical activity across time.

    PubMed

    Lima, R A; Pfeiffer, K A; Bugge, A; Møller, N C; Andersen, L B; Stodden, D F

    2017-12-01

    We investigated the longitudinal associations among physical activity (PA), motor competence (MC), cardiorespiratory fitness (VO 2peak ), and body fatness across 7 years, and also analyzed the possible mediation effects of PA, MC, and VO 2peak on the relationships with body fatness. This was a seven-year longitudinal study with three measuring points (mean ages [in years] and respective sample size: 6.75±0.37, n=696; 9.59±1.07, n=617; 13.35±0.34, n=513). PA (moderate-to-vigorous PA-MVPA and vigorous PA-VPA) was monitored using accelerometers. MC was assessed by the "Körperkoordinationstest für Kinder-KTK" test battery. VO 2peak was evaluated using a continuous running protocol until exhaustion. Body fatness was determined by the sum of four skinfolds. Structural equation modeling was performed to evaluate the longitudinal associations among PA, MC, VO 2peak, and body fatness and the potential mediation effects of PA, MC, and VO 2peak . All coefficients presented were standardized (z-scores). MC and VO 2peak directly influenced the development of body fatness, and VO 2peak mediated the associations between MVPA, VPA, MC, and body fatness. MC also mediated the associations between MVPA, VPA, and body fatness. In addition, VO 2peak had the largest total association with body fatness (β=-0.431; P<.05), followed by MC (β=-0.369; P<.05) and VPA (β=-0.112; P<.05). As PA, MC, and VO 2peak exhibited longitudinal association with body fatness, it seems logical that interventions should strive to promote the development of fitness and MC through developmentally appropriate physical activities, as the synergistic interactions of all three variables impacted body fatness. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. CeVO4 nanofibers hybridized with g-C3N4 nanosheets with enhanced visible-light-driven photocatalytic activity

    NASA Astrophysics Data System (ADS)

    Li, Li; Wang, Haoran; Wang, Xiong

    2018-01-01

    The g-C3N4/CeVO4 composites were successfully synthesized by hybridizing CeVO4 nanofibers with g-C3N4 nanosheets. The photocatalytic activity of g-C3N4/CeVO4 composites was evaluated for the photodegradation of methylene blue under visible light irradiation. Among them, the 50 wt% g-C3N4/CeVO4 composites presented the highest photocatalytic activity, about 2 and 3.2 times higher than those of CeVO4 and g-C3N4, respectively. The improved catalytic activity was owed to the hybridization, which facilitated the rapid separation of photoinduced carriers and enhanced the visible light harvesting. A possible photocatalytic mechanism was proposed.

  1. High-performance porous spherical or octapod-like single-crystalline BiVO4 photocatalysts for the removal of phenol and methylene blue under visible-light illumination.

    PubMed

    Jiang, Haiyan; Meng, Xue; Dai, Hongxing; Deng, Jiguang; Liu, Yuxi; Zhang, Lei; Zhao, Zhenxuan; Zhang, Ruzhen

    2012-05-30

    Monoclinic BiVO(4) single-crystallites with a polyhedral, spherical or porous octapod-like morphology were selectively prepared using the triblock copolymer P123 (HO(CH(2)CH(2)O)(20)(CH(2)CH(CH(3))O)(70)(CH(2)CH(2)O)(20)H)-assisted hydrothermal method with bismuth nitrate and ammonium metavanadate as metal source and various bases as pH adjustor. The BiVO(4) materials were well characterized and their photocatalytic activities were evaluated for the removal of methylene blue (MB) and phenol in the presence of a small amount of H(2)O(2) under visible-light illumination. It is shown that the pH value of the precursor solution, surfactant, and hydrothermal temperature had an important impact on particle architecture of the BiVO(4) product. The introduction of P123 favored the generation of BiVO(4) with porous structures. The BiVO(4) derived hydrothermally with P123 at pH 3 or 6 possessed good optical absorption performance both in UV- and visible-light regions and hence showed excellent photocatalytic activities for the degradation of MB and phenol. It is concluded that the high visible-light-driven catalytic performance of the porous octapod-like BiVO(4) single-crystallites is associated with the higher surface area, porous structure, lower band gap energy, and unique particle morphology. Such porous BiVO(4) materials are useful in the solar-light-driven photocatalytic treatment of organic-containing wastewater. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Near-zero IR transmission of VO2 thin films deposited on Si substrate

    NASA Astrophysics Data System (ADS)

    Zhang, Chunzi; Koughia, Cyril; Li, Yuanshi; Cui, Xiaoyu; Ye, Fan; Shiri, Sheida; Sanayei, Mohsen; Wen, Shi-Jie; Yang, Qiaoqin; Kasap, Safa

    2018-05-01

    Vanadium dioxide (VO2) thin films of different thickness have been deposited on Si substrates by using DC magnetron sputtering. The effects of substrate pre-treatment by means of seeding (spin coating and ultrasonic bathing) and biasing on the structure and optical properties were investigated. Seeding results in a smaller grain size in the oxide film, whereas biasing results in square-textured crystals. VO2 thin films of 150 nm thick show a near-zero IR transmission in switched state. Especially, the 150 nm thick VO2 thin film with seeding treatment shows an enhanced switching efficiency.

  3. Effect of a 17 day spaceflight on contractile properties of human soleus muscle fibres

    PubMed Central

    Widrick, J J; Knuth, S T; Norenberg, K M; Romatowski, J G; Bain, J L W; Riley, D A; Karhanek, M; Trappe, S W; Trappe, T A; Costill, D L; Fitts, R H

    1999-01-01

    Soleus biopsies were obtained from four male astronauts 45 days before and within 2 h after a 17 day spaceflight. For all astronauts, single chemically skinned post-flight fibres expressing only type I myosin heavy chain (MHC) developed less average peak Ca2+ activated force (Po) during fixed-end contractions (0.78 ± 0.02 vs. 0.99 ± 0.03 mN) and shortened at a greater mean velocity during unloaded contractions (Vo) (0.83 ± 0.02 vs. 0.64 ± 0.02 fibre lengths s−1) than pre-flight type I fibres. The flight-induced decline in absolute Po was attributed to reductions in fibre diameter and/or Po per fibre cross-sectional area. Fibres from the astronaut who experienced the greatest relative loss of peak force also displayed a reduction in Ca2+ sensitivity. The elevated Vo of the post-flight slow type I fibres could not be explained by alterations in myosin heavy or light chain composition. One alternative possibility is that the elevated Vo resulted from an increased myofilament lattice spacing. This hypothesis was supported by electron micrographic analysis demonstrating a reduction in thin filament density post-flight. Post-flight fibres shortened at 30 % higher velocities than pre-flight fibres at external loads associated with peak power output. This increase in shortening velocity either reduced (2 astronauts) or prevented (2 astronauts) a post-flight loss in fibre absolute peak power (μN (fibre length) s−1). The changes in soleus fibre diameter and function following spaceflight were similar to those observed after 17 days of bed rest. Although in-flight exercise countermeasures probably reduced the effects of microgravity, the results support the idea that ground-based bed rest can serve as a model of human spaceflight. In conclusion, 17 days of spaceflight decreased force and increased shortening velocity of single Ca2+-activated muscle cells expressing type I MHC. The increase in shortening velocity greatly reduced the impact that impaired force production had on absolute peak power. PMID:10200437

  4. Analysis of swimming performance from physical, physiological, and biomechanical parameters in young swimmers.

    PubMed

    Jürimäe, Jaak; Haljaste, Kaja; Cicchella, Antonio; Lätt, Evelin; Purge, Priit; Leppik, Aire; Jürimäe, Toivo

    2007-02-01

    The purpose of this study was to examine the influence of the energy cost of swimming, body composition, and technical parameters on swimming performance in young swimmers. Twenty-nine swimmers, 15 prepubertal (11.9 +/- 0.3 years; Tanner Stages 1-2) and 14 pubertal (14.3 +/- 1.4 years; Tanner Stages 3-4) boys participated in the study. The energy cost of swimming (Cs) and stroking parameters were assessed over maximal 400-m front-crawl swimming in a 25-m swimming pool. The backward extrapolation technique was used to evaluate peak oxygen consumption (VO2peak). A stroke index (SI; m2 . s(-1) . cycles(-1)) was calculated by multiplying the swimming speed by the stroke length. VO2peak results were compared with VO2peak test in the laboratory (bicycle, 2.86 +/- 0.74 L/min, vs. in water, 2.53 +/- 0.50 L/min; R2 = .713; p = .0001). Stepwise-regression analyses revealed that SI (R2 = .898), in-water VO2peak (R2 = .358), and arm span (R2 = .454) were the best predictors of swimming performance. The backward-extrapolation method could be used to assess VO2peak in young swimmers. SI, arm span, and VO2peak appear to be the major determinants of front-crawl swimming performance in young swimmers.

  5. Metabolism and ventilation in hypoxic rats: effect of body mass.

    PubMed

    Mortola, J P; Matsuoka, T; Saiki, C; Naso, L

    1994-07-01

    Oxygen consumption (VO2) and carbon dioxide production (VCO2) were measured by the flow-through method, and ventilation (VE) by the barometric technique in post-weaning age rats of 50, 100, 250 and 400 g, (5 males and 5 females in each group), at ambient temperature congruent to 24 degrees C. In normoxia, VO2, VCO2 and VE decreased with the increase in body weight (BW), whether normalization was by BW or by BW minus the weights of fat and skeleton; VE/VO2 and rectal temperature remained constant. In hypoxia (10% inspired O2), VE VO2 increased in all groups, to 2-2.5 times the normoxic values, because of a significant increase in VE (hyperpnea) and decrease in VO2 (hypometabolism); arterial PCO2, measured in some 100 g and 400 g rats, dropped similarly. However, the hyperpnea was about twice as large, and metabolism and body temperature decreased significantly less, in the 400 g than in the 50 g rats. The cost (ml O2) of breathing, computed in the paralysed animal artificially ventilated, averaged approximately 0.7% (normoxia) and 2% of VO2 (hypoxia), with no systematic differences with BW. The results agree with the concept that the metabolic response to hypoxia can be an important determinant of the magnitude of the hyperpnea.

  6. Ferromagnetism induced by oxygen-vacancy complex in (Mn, in) codoped ZnO

    NASA Astrophysics Data System (ADS)

    Wu, Kongping; Gu, Shulin; Tang, Kun; Zhu, Shunming; Zhou, Mengran; Huang, Yourui; Xu, Mingxiang; Zhang, Rong; Zheng, Youdou

    2012-07-01

    Mn doped Zinc oxide (ZnO) thin films were prepared by metal organic chemical vapor deposition (MOCVD) technique. Structural characterizations by X-ray diffraction technique (XRD) and photoluminescence (PL) indicate the crystal quality of ZnO films. PL and Raman show a large fraction of oxygen vacancies (VO2+) are generated by vacuum annealed the film. The enhancement of ferromagnetism in post-annealed (Mn, In) codoped ZnO could result from VO2+ incorporation. The effect of VO2+ on the magnetic properties of (Mn, In) codoped ZnO has been studied by first-principles calculations. It is found that only In donor cannot induce ferromagnetism (FM) in Mn-doped ZnO. Besides, the presence of VO2+ makes the Mn empty 3d-t2g minority state broadened, and a t2g-VO2+ hybrid level at the conduction band minimum forms. The presence of VO2+ can lead to strong ferromagnetic coupling with the nearest neighboring Mn cation by BMP model based on defects reveal that the ferromagnetic exchange is mediated by the donor impurity state, which mainly consists of Mn 3d electrons trapped in oxygen vacancies.

  7. Evidence of cardiac functional reserve upon exhaustion during incremental exercise to determine VO2max.

    PubMed

    Elliott, Adrian D; Skowno, Justin; Prabhu, Mahesh; Noakes, Timothy David; Ansley, Les

    2015-01-01

    There remains considerable debate regarding the limiting factor(s) for maximal oxygen uptake (VO2max). Previous studies have shown that the central circulation may be the primary limiting factor for VO2max and that cardiac work increases beyond VO2max. We sought to evaluate whether the work of the heart limits VO2max during upright incremental cycle exercise to exhaustion. Eight trained men completed two incremental exercise trials, each terminating with exercise at two different rates of work eliciting VO2max (MAX and SUPRAMAX). During each exercise trial we continuously recorded cardiac output using pulse-contour analysis calibrated with a lithium dilution method. Intra-arterial pressure was recorded from the radial artery while pulmonary gas exchange was measured continuously for an assessment of oxygen uptake. The workload during SUPRAMAX (mean±SD: 346.5±43.2 W) was 10% greater than that achieved during MAX (315±39.3 W). There was no significant difference between MAX and SUPRAMAX for Q (28.7 vs 29.4 L/min) or VO2 (4.3 vs 4.3 L/min). Mean arterial pressure was significantly higher during SUPRAMAX, corresponding to a higher cardiac power output (8.1 vs 8.5 W; p<0.06). Despite similar VO2 and Q, the greater cardiac work during SUPRAMAX supports the view that the heart is working submaximally at exhaustion during an incremental exercise test (MAX). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  8. Angle-independent VO2 Thin Film on Glass Fiber Cloth as a Soft-Smart-Mirror (SSM)

    PubMed Central

    Cai, Nianjin; Zhang, Wang; Wang, Wanlin; Zhu, Yuchen; Zada, Imran; Gu, Jiajun; Liu, Qinglei; Su, Huilan; Guo, Cuiping; Zhang, Zhijian; Zhang, Jianzhong; Wu, Liping; Zhang, Di

    2016-01-01

    Designing materials with a negative feedback function is beneficial for achieving temperature regulation inside a greenhouse. VO2 has been studied extensively because of its low insulator-to-metal transition temperature (IMT). In this study, reflection changes during a VO2 phase transition were investigated. Glass fiber cloth was used as a substrate, as it is stable and soft. A VO2 thin film on a glass fiber cloth whose surface contained 96% V4+ and 4% V5+ was prepared using an inorganic sol-gels method. The insulator-to-metal transition temperature was decreased by 38 °C, which was observed from the reflection curve detected using an angle-resolved spectrometer. This decrease in IMT occurred mainly because of the presence of V5+, which causes destabilization of the monoclinic phase of VO2. When the greenhouse temperature was increased from 30 °C to 40 °C, the reflected intensity of VO2 on glass fiber cloth decreased by 22% for the wavelength range of 400 nm to 800 nm. In addition, the angle-independent property of the VO2 thin film was observed using an angle-resolved spectrometer. Owing to its thermo-reflective properties, the thin film can serve as a soft-smart-mirror (SSM) inside a greenhouse to stabilize the temperature, playing a negative feedback role. PMID:27849051

  9. Angle-independent VO2 Thin Film on Glass Fiber Cloth as a Soft-Smart-Mirror (SSM)

    NASA Astrophysics Data System (ADS)

    Cai, Nianjin; Zhang, Wang; Wang, Wanlin; Zhu, Yuchen; Zada, Imran; Gu, Jiajun; Liu, Qinglei; Su, Huilan; Guo, Cuiping; Zhang, Zhijian; Zhang, Jianzhong; Wu, Liping; Zhang, Di

    2016-11-01

    Designing materials with a negative feedback function is beneficial for achieving temperature regulation inside a greenhouse. VO2 has been studied extensively because of its low insulator-to-metal transition temperature (IMT). In this study, reflection changes during a VO2 phase transition were investigated. Glass fiber cloth was used as a substrate, as it is stable and soft. A VO2 thin film on a glass fiber cloth whose surface contained 96% V4+ and 4% V5+ was prepared using an inorganic sol-gels method. The insulator-to-metal transition temperature was decreased by 38 °C, which was observed from the reflection curve detected using an angle-resolved spectrometer. This decrease in IMT occurred mainly because of the presence of V5+, which causes destabilization of the monoclinic phase of VO2. When the greenhouse temperature was increased from 30 °C to 40 °C, the reflected intensity of VO2 on glass fiber cloth decreased by 22% for the wavelength range of 400 nm to 800 nm. In addition, the angle-independent property of the VO2 thin film was observed using an angle-resolved spectrometer. Owing to its thermo-reflective properties, the thin film can serve as a soft-smart-mirror (SSM) inside a greenhouse to stabilize the temperature, playing a negative feedback role.

  10. Angle-independent VO2 Thin Film on Glass Fiber Cloth as a Soft-Smart-Mirror (SSM).

    PubMed

    Cai, Nianjin; Zhang, Wang; Wang, Wanlin; Zhu, Yuchen; Zada, Imran; Gu, Jiajun; Liu, Qinglei; Su, Huilan; Guo, Cuiping; Zhang, Zhijian; Zhang, Jianzhong; Wu, Liping; Zhang, Di

    2016-11-16

    Designing materials with a negative feedback function is beneficial for achieving temperature regulation inside a greenhouse. VO 2 has been studied extensively because of its low insulator-to-metal transition temperature (IMT). In this study, reflection changes during a VO 2 phase transition were investigated. Glass fiber cloth was used as a substrate, as it is stable and soft. A VO 2 thin film on a glass fiber cloth whose surface contained 96% V 4+ and 4% V 5+ was prepared using an inorganic sol-gels method. The insulator-to-metal transition temperature was decreased by 38 °C, which was observed from the reflection curve detected using an angle-resolved spectrometer. This decrease in IMT occurred mainly because of the presence of V 5+ , which causes destabilization of the monoclinic phase of VO 2 . When the greenhouse temperature was increased from 30 °C to 40 °C, the reflected intensity of VO 2 on glass fiber cloth decreased by 22% for the wavelength range of 400 nm to 800 nm. In addition, the angle-independent property of the VO 2 thin film was observed using an angle-resolved spectrometer. Owing to its thermo-reflective properties, the thin film can serve as a soft-smart-mirror (SSM) inside a greenhouse to stabilize the temperature, playing a negative feedback role.

  11. Relationship between aerobic capacity and pelvic floor muscles function: a cross-sectional study

    PubMed Central

    Jürgensen, S.P.; Borghi-Silva, A.; Bastos, A.M.F.G.; Correia, G.N.; Pereira-Baldon, V.S.; Cabiddu, R.; Catai, A.M.; Driusso, P.

    2017-01-01

    The objective of this study was to evaluate the relationship between aerobic capacity and pelvic floor muscles (PFM) function in adult women. Women aged 18 or over and without urinary dysfunction or other chronic diseases were eligible to participate. They completed the habitual physical activity (HPA) questionnaire, underwent a PFM functional evaluation by palpation and perineometry, and performed a submaximal (between 75 and 85% of maximum heart rate) cardiopulmonary exercise (CPX) test to determine the ventilatory anaerobic threshold (VAT). Forty-one women were included (35±16 years, 75% physically active, 17% very active, and 8% sedentary and 17% presented grade 1 PFM contraction, 31.8% grade 2, 26.8% grade 3, and 24.4% grade 4, according to the modified Oxford Scale). The average PFM contraction pressure obtained by perineometer was 53±26 cmH2O and the average oxygen consumption at VAT (VO2VAT) obtained from CPX was 14±2 mL·kg-1·min-1. Significant correlations were found between PFM contraction pressure and VO2VAT (r=0.55; P<0.001); between PFM contraction pressure and HPA score (r=0.38; P=0.02); between age and VO2VAT (r=-0.25; P=0.049); and between VO2VAT and HPA score (r=0.36; P=0.02). An age-adjusted multiple linear regression equation (R2=0.32) was derived to estimate VO2VAT from the contraction value obtained by perineometer, so that the PFM contraction pressure was able to predict VO2VAT. The equation was validated using data from another group of 20 healthy women (33±12 years; PFM contraction: 49±23 cmH2O) and no significant difference was found between actual VO2VAT and predicted VO2VAT (13.1±1.9 vs 13.8±2.0 mL·kg-1·min-1). In conclusion, PFM function is associated with aerobic capacity in healthy women and PFM contraction pressure may be used to estimate VO2VAT in this population. PMID:28953985

  12. Oscillation in O2 uptake in impulse exercise.

    PubMed

    Yano, T; Afroundeh, R; Yamanaka, R; Arimitsu, T; Lian, C S; Shirakawa, K; Yunoki, T

    2014-06-01

    The purpose of the present study was to examine 1) whether O(2) uptake (VO(2)) oscillates during light exercise and 2) whether the oscillation is enhanced after impulse exercise. After resting for 1 min on a bicycle seat, subjects performed 5-min pre-exercise with 25 watts work load, 10-s impulse exercise with 200 watts work load and 15-min post exercise with 25 watts work load at 80 rpm. VO(2) during pre-exercise significantly increased during impulse exercise and suddenly decreased and re-increased until 23 s after impulse exercise. In the cross correlation between heart rate (HR) and VO(2) after impulse exercise, VO(2) strongly correlated to HR with a time delay of -4 s. Peak of power spectral density (PSD) in HR appeared at 0.0039 Hz and peak of PSD in VO(2) appeared at 0.019 Hz. The peak of the cross power spectrum between VO(2) and HR appeared at 0.0078 Hz. The results suggested that there is an oscillation in O(2) uptake during light exercise that is associated with the oscillation in O(2) consumption in active muscle. The oscillation is enhanced not only by change in O(2) consumption but also by O(2) content transported from active muscle to the lungs.

  13. The VO-Dance web application at the IA2 data center

    NASA Astrophysics Data System (ADS)

    Molinaro, Marco; Knapic, Cristina; Smareglia, Riccardo

    2012-09-01

    Italian center for Astronomical Archives (IA2, http://ia2.oats.inaf.it) is a national infrastructure project of the Italian National Institute for Astrophysics (Istituto Nazionale di AstroFisica, INAF) that provides services for the astronomical community. Besides data hosting for the Large Binocular Telescope (LBT) Corporation, the Galileo National Telescope (Telescopio Nazionale Galileo, TNG) Consortium and other telescopes and instruments, IA2 offers proprietary and public data access through user portals (both developed and mirrored) and deploys resources complying the Virtual Observatory (VO) standards. Archiving systems and web interfaces are developed to be extremely flexible about adding new instruments from other telescopes. VO resources publishing, along with data access portals, implements the International Virtual Observatory Alliance (IVOA) protocols providing astronomers with new ways of analyzing data. Given the large variety of data flavours and IVOA standards, the need for tools to easily accomplish data ingestion and data publishing arises. This paper describes the VO-Dance tool, that IA2 started developing to address VO resources publishing in a dynamical way from already existent database tables or views. The tool consists in a Java web application, potentially DBMS and platform independent, that stores internally the services' metadata and information, exposes restful endpoints to accept VO queries for these services and dynamically translates calls to these endpoints to SQL queries coherent with the published table or view. In response to the call VO-Dance translates back the database answer in a VO compliant way.

  14. Oxygen-saving effect of a new cardiotonic agent, MCI-154, in diseased human hearts.

    PubMed

    Mori, M; Takeuchi, M; Takaoka, H; Hata, K; Hayashi, Y; Yamakawa, H; Yokoyama, M

    1997-03-01

    The aim of this study was to examine the left ventricular mechanoenergetic effects of a novel Ca2+ sensitizing agent, MCI-154, on diseased human hearts compared with dobutamine. Unlike conventional cardiotonic agents, a Ca2+ sensitizer that could produce a positive inotropic action by altering the responsiveness of myofilament to Ca2+ could generate force with smaller amounts of Ca2+; thus, it may potentially save energy expenditure. The left ventricular pressure-volume relation and myocardial oxygen consumption per beat (Vo2) were measured by a conductance (volume) catheter and a Webster catheter. Left ventricular contractility (Emax), systolic pressure-volume area (PVA [index of left ventricular total mechanical energy]) and Vo2 were assessed before and after infusion of MCI-154 or dobut-amine. The PVA-independent Vo2 (Vo2 mainly for excitation-contraction coupling) was assessed as the Vo2 at zero PVA. Both agents increased Emax comparably (dobutamine: from 3.55 +/- 1.10 [mean +/- SD] to 5.04 +/- 1.16 mm Hg/ml per m2, p < 0.0001; MCI-154: from 3.36 +/- 1.26 to 5.37 +/- 2.14 mm Hg/ml per m2, p < 0.0001); dobutamine increased total Vo2 (from 0.22 +/- 0.08 to 0.27 +/- 0.09 ml O2, p < 0.05) and PVA-independent Vo2 (from 0.019 +/- 0.019 to 0.091 +/- 0.051 ml O2, p < 0.005); but MCI-154 did not change these variables significantly. Consequently, the oxygen cost of contractility (delta PVA-independent Vo2/delta Emax) was less with MCI-154 than with dobutamine (0.14 +/- 0.18 vs. 1.10 +/- 0.80 J/mm Hg per ml per m2, p < 0.05). These results suggest that the cardiotonic action mediated by MCI-154 could provide an energetic advantage over the conventional cardiotonic action with currently used inotropic agents.

  15. Efficient solar-driven water splitting by nanocone BiVO4-perovskite tandem cells

    PubMed Central

    Qiu, Yongcai; Liu, Wei; Chen, Wei; Chen, Wei; Zhou, Guangmin; Hsu, Po-Chun; Zhang, Rufan; Liang, Zheng; Fan, Shoushan; Zhang, Yuegang; Cui, Yi

    2016-01-01

    Bismuth vanadate (BiVO4) has been widely regarded as a promising photoanode material for photoelectrochemical (PEC) water splitting because of its low cost, its high stability against photocorrosion, and its relatively narrow band gap of 2.4 eV. However, the achieved performance of the BiVO4 photoanode remains unsatisfactory to date because its short carrier diffusion length restricts the total thickness of the BiVO4 film required for sufficient light absorption. We addressed the issue by deposition of nanoporous Mo-doped BiVO4 (Mo:BiVO4) on an engineered cone-shaped nanostructure, in which the Mo:BiVO4 layer with a larger effective thickness maintains highly efficient charge separation and high light absorption capability, which can be further enhanced by multiple light scattering in the nanocone structure. As a result, the nanocone/Mo:BiVO4/Fe(Ni)OOH photoanode exhibits a high water-splitting photocurrent of 5.82 ± 0.36 mA cm−2 at 1.23 V versus the reversible hydrogen electrode under 1-sun illumination. We also demonstrate that the PEC cell in tandem with a single perovskite solar cell exhibits unassisted water splitting with a solar-to-hydrogen conversion efficiency of up to 6.2%. PMID:27386565

  16. Does Citrulline Malate Enhance Physical Performance

    DTIC Science & Technology

    2010-10-01

    Jakeman, P.M. (2010). Citrulline malate enhances athletic anaerobic performance and relieves muscle soreness. Journal of Strength and Conditioning...returned for their third and final VO2 max test. VO2max, lactate threshold , maximum watts reached, ratings of perceived exertion and pre- and post...7 Figure 7. Lactate threshold (as % of VO2max) for all three conditions

  17. Measurement of gas exchange in intensive care: laboratory and clinical validation of a new device.

    PubMed

    Takala, J; Keinänen, O; Väisänen, P; Kari, A

    1989-10-01

    The performance of a new gas exchange monitor was assessed both in laboratory simulation and in ICU patients. Laboratory simulation using N2 and CO2 injections resulted in a mean error of 2 +/- 2% in CO2 production (VCO2) and 4 +/- 4% in oxygen consumption (VO2) in respirator measurements (n = 55) and in a mean error of 3 +/- 2% in VCO2 and 4 +/- 2% in VO2 in canopy measurements (n = 25). The mean error in RQ during ethanol burning was 2 +/- 2% in respirator measurements (n = 45) and 1 +/- 1% in canopy measurements. FIO2 had little effect on the accuracy of VCO2, whereas the accuracy on high rates of VO2 (VO2 = 400 ml/min) was reduced, when FIO2 increased: the error ranged from 1 +/- 1% to 6 +/- 1%, except at VO2 400 ml/min during FIO2 0.8, where the error was 16 +/- 3%. Neither peak airway pressure (+13 to +63 cm H2O) nor PEEP (0 to +20 cm H2O) had an effect on the accuracy. The highest level of minute ventilation studied (22.5 L/min) reduced the accuracy slightly (mean error of VCO2 4 +/- 1% and VO2 7 +/- 2%). In patients during controlled mechanical ventilation, increasing FIO2 from 0.4 to 0.6 had no effect on the results. VO2 was consistently higher by gas exchange than by the Fick principle: 16 +/- 9% during controlled ventilation (n = 20), 21 +/- 8% on synchronized intermittent mandatory ventilation (n = 10) and 25 +/- 8% during spontaneous breathing. We conclude that the device proved to be accurate for gas exchange measurements in the ICU.

  18. Respiratory response of grass carp Ctenopharyngodon idellus to dissolved oxygen changes at three acclimation temperatures.

    PubMed

    Zhao, Zhigang; Dong, Shuanglin; Xu, Qiyou

    2018-02-01

    Respiratory parameters of grass carp were studied during dissolved oxygen (DO) changes from normal DO to hypoxia, then return to normal DO at 15, 25, and 30 °C acclimation, respectively. The results showed that with increases of acclimation temperature at normoxia the respiratory frequency (f R ), oxygen consumption rate (VO 2 ), respiratory stroke volume (V S.R ), gill ventilation (V G ), and V G /VO 2 of grass carp increased significantly, but the oxygen extraction efficiency (EO 2 ) of fish decreased significantly (P < 0.05). With declines of DO levels, the f R , V S.R , V G , and V G /VO 2 of fish increased significantly at different acclimation temperatures (P < 0.05). A slight increase was found in VO 2 , and the EO 2 of fish remained almost constant above DO levels of 3.09, 2.91, and 2.54 mg l -1 at 15, 25, and 30 °C, while the VO 2 and EO 2 began to decrease significantly with further reductions in DO levels (P < 0.05). After 0.5 h of recovery to normoxia from hypoxia at three acclimation, the f R , V S.R , V G , and V G /VO 2 of the fish decreased sharply; meanwhile, the VO 2 and EO 2 increased sharply (P < 0.05). The respiratory parameters of fish gradually approached initial values with prolonged recovery time to normoxia, and reached their initial values in 2.5 h at 25 and 30 °C acclimation. The critical oxygen concentrations (C c ) of fish for VO 2 were 2.42 mg l -1 at 15 °C, 2.02 mg l -1 at 25 °C, and 1.84 mg l -1 at 30 °C, respectively. The results suggest that grass carp are highly adapted to varied DO and short-term hypoxia environments.

  19. Temperature and electric field induced metal-insulator transition in atomic layer deposited VO2 thin films

    NASA Astrophysics Data System (ADS)

    Tadjer, Marko J.; Wheeler, Virginia D.; Downey, Brian P.; Robinson, Zachary R.; Meyer, David J.; Eddy, Charles R.; Kub, Fritz J.

    2017-10-01

    Amorphous vanadium oxide (VO2) films deposited by atomic layer deposition (ALD) were crystallized with an ex situ anneal at 660-670 °C for 1-2 h under a low oxygen pressure (10-4 to 10-5 Torr). Under these conditions the crystalline VO2 phase was maintained, while formation of the V2O5 phase was suppressed. Electrical transition from the insulator to the metallic phase was observed in the 37-60 °C range, with an ROFF/RON ratio of up to about 750 and ΔTC ≅ 7-10 °C. Lateral electric field applied across two-terminal device structures induced a reversible phase change, with a room temperature transition field of about 25 kV/cm in the VO2 sample processed with the 2 h long O2 anneal. Both the width and slope of the field induced MIT I-V hysteresis were dependent upon the VO2 crystalline quality.

  20. Synthesis and structural characterization of the hexagonal anti-perovskite Na{sub 2}CaVO{sub 4}F

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, Robert L., E-mail: rgreen@flpoly.org; Avdeev, Maxim; School of Chemistry, The University of Sydney, Sydney, NSW 2006

    The structural details of the ordered hexagonal oxyfluoride Na{sub 2}CaVO{sub 4}F prepared by solid-state synthesis using stoichiometric amounts of V{sub 2}O{sub 5}, CaCO{sub 3}, Na{sub 2}CO{sub 3} and NaF were characterized using high-resolution neutron powder diffraction. The structural changes between 25 °C and 750 °C revealed that the two structural subunits in this material behave different when heated: there is an expansion of the face-shared FNa{sub 4}Ca{sub 2} octahedra while the VO{sub 4} tetrahedra due to increased thermal disorder reveal marginal bond contractions. Bond valences and the global instability index point to significant structural disorder at 750 °C. - Graphicalmore » abstract: The structure of the novel oxyfluoride Na{sub 2}CaVO{sub 4}F is studied at room temperature and high-temperatures. The structure can be viewed as layers of compression and elongation of polyhedral subunits, which change as a function of temperature. - Highlights: • The novel oxyfluoride, Na{sub 2}CaVO{sub 4}F, is synthesized via solid-state method. • High-resolution neutron diffraction data is used to analyze the structure of Na{sub 2}CaVO{sub 4}F. • Structural subunits exhibit expansion and contraction with increasing temperature. • Higher temperatures increase instability within the structure of Na{sub 2}CaVO{sub 4}F.« less

Top