Sample records for void urine samples

  1. Urine Monitoring System

    NASA Technical Reports Server (NTRS)

    Feedback, Daniel L.; Cibuzar, Branelle R.

    2009-01-01

    The Urine Monitoring System (UMS) is a system designed to collect an individual crewmember's void, gently separate urine from air, accurately measure void volume, allow for void sample acquisition, and discharge remaining urine into the Waste Collector Subsystem (WCS) onboard the International Space Station. The Urine Monitoring System (UMS) is a successor design to the existing Space Shuttle system and will resolve anomalies such as: liquid carry-over, inaccurate void volume measurements, and cross contamination in void samples. The crew will perform an evaluation of airflow at the ISS UMS urinal hose interface, a calibration evaluation, and a full user interface evaluation. o The UMS can be used to facilitate non-invasive methods for monitoring crew health, evaluation of countermeasures, and implementation of a variety of biomedical research protocols on future exploration missions.

  2. Optimizing Urine Processing Protocols for Protein and Metabolite Detection.

    PubMed

    Siddiqui, Nazema Y; DuBois, Laura G; St John-Williams, Lisa; Will, Thompson J; Grenier, Carole; Burke, Emily; Fraser, Matthew O; Amundsen, Cindy L; Murphy, Susan K

    In urine, factors such as timing of voids, and duration at room temperature (RT) may affect the quality of recovered protein and metabolite data. Additives may aid with detection, but can add more complexity in sample collection or analysis. We aimed to identify the optimal urine processing protocol for clinically-obtained urine samples that allows for the highest protein and metabolite yields with minimal degradation. Healthy women provided multiple urine samples during the same day. Women collected their first morning (1 st AM) void and another "random void". Random voids were aliquotted with: 1) no additive; 2) boric acid (BA); 3) protease inhibitor (PI); or 4) both BA + PI. Of these aliquots, some were immediately stored at 4°C, and some were left at RT for 4 hours. Proteins and individual metabolites were quantified, normalized to creatinine concentrations, and compared across processing conditions. Sample pools corresponding to each processing condition were analyzed using mass spectrometry to assess protein degradation. Ten Caucasian women between 35-65 years of age provided paired 1 st morning and random voided urine samples. Normalized protein concentrations were slightly higher in 1 st AM compared to random "spot" voids. The addition of BA did not significantly change proteins, while PI significantly improved normalized protein concentrations, regardless of whether samples were immediately cooled or left at RT for 4 hours. In pooled samples, there were minimal differences in protein degradation under the various conditions we tested. In metabolite analyses, there were significant differences in individual amino acids based on the timing of the void. For comparative translational research using urine, information about void timing should be collected and standardized. For urine samples processed in the same day, BA does not appear to be necessary while the addition of PI enhances protein yields, regardless of 4°C or RT storage temperature.

  3. Development of an Inline Urine Monitoring System for the International Space Station

    NASA Technical Reports Server (NTRS)

    Broyan, James Lee, Jr.; Cibuzar, Banelle R.

    2008-01-01

    Human exposure to microgravity during spaceflight causes bone loss. Calcium and other metabolic byproducts are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is essential to determining crew bone loss and the effectiveness of countermeasures. Previous US Space Shuttle (SS) Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to cross contamination between users and fluid system instabilities. Currently, urine voids must be collected manually in a flexible plastic bag containing a known tracer quantity. The crew member must completely mix the bag then withdraw a representative syringe sample for later ground analysis. The current bag system accuracy is highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures the void volume, and allows for syringe sampling. After operations, the ISS UMS delivers the urine to the WHC for normal processing then flushes its plumbing with a small water volume. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, greatly reduces cross contamination between urine voids (< 0.5 ml urine), and provides accurate volume measurements (< +/- 2% error for 100 to 1000 ml void volumes). The system performance has been validated with extensive ground tests and reduced gravity aircraft flights. The lockersized ISS UMS is currently being modified to interface with the ISS Node 3 WHC Russian ACY hardware. The operation principles, characteristics, and results are outlined in the paper.

  4. Development of an In-line Urine Monitoring System for the International Space Station

    NASA Technical Reports Server (NTRS)

    Broyan, James Lee, Jr.; Cibuzar, Branelle R.

    2009-01-01

    Exposure to microgravity during space flight causes bone loss when calcium and other metabolic by-products are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is thus essential in determining crew bone loss and the effectiveness of the countermeasures that are taken to minimize this loss. Earlier space shuttle Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to the cross-contamination that took place between users, as well as to fluid system instabilities. Crew urine voids are currently collected manually in a flexible plastic bag that contains a known tracer quantity. A crew member must completely mix the contents of this bag before withdrawing a representative syringe sample for later ground analysis. The existing bag system accuracy is therefore highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures void volume, and allows for syringe sampling. After the ISS UMS has been used by a crew member, it delivers urine to the WHC for normal processing. The UMS plumbing is then flushed with a small volume of water. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, consequently greatly reducing cross-contamination among urine voids (less than 0.5 mL urine) while also providing accurate volume measurements (less than 2 percent error for 100 to 1,000 mL void volumes). ISS UMS performance has been validated through extensive ground tests and reduced-gravity aircraft flights. The locker-sized ISS UMS is currently undergoing a design modification that will permit it to interface with the ISS Node 3 WHC Russian toilet (ACY) hardware. The operating principles, characteristics, and results of this design modification are outlined here.

  5. Objective non-intrusive markers of sperm production and sexual activity

    PubMed Central

    Sivananthan, Thilee; Bathur, Franz; Jimenez, Mark; Conway, Ann; Idan, Amanda; Handelsman, David

    2012-01-01

    Objective studies of men's reproductive function are hindered by their reliance on: (i) self-reporting to quantify sexual activity and (ii) masturbation to quantify sperm output rendering both types of estimate vulnerable to unverifiable subjective factors. We therefore examined whether detection of spermatozoa and measurement of prostate-specific antigen (PSA) in urine could provide objective semiquantitative estimates of sperm output and recent ejaculation, respectively, using widely available laboratory techniques. Of 11 healthy volunteers who provided urine samples before and at intervals for 5 days after ejaculation, sperm was present in 2/11 men before, and in all 11/11 samples immediately after ejaculation, but by the second and subsequent void, spermatozoa were present in ∼10%. PSA was detectable at high levels in all urine samples, peaking at the first post-ejaculatory sample but returning to baseline levels by the second post-ejaculatory void. We conclude that urinary spermatozoa and PSA are objective biomarkers for sperm production and sexual activity, but only for a short-time window until the first post-ejaculatory urine void. Hence, for a single urine specimen, the presence of spermatozoa and PSA are valid biomarkers, reflecting sperm production and recent ejaculation only until the next micturition, so their measurement should be restricted to the first morning urine void. PMID:22522506

  6. First-void urine: A potential biomarker source for triage of high-risk human papillomavirus infected women.

    PubMed

    Van Keer, Severien; Pattyn, Jade; Tjalma, Wiebren A A; Van Ostade, Xaveer; Ieven, Margareta; Van Damme, Pierre; Vorsters, Alex

    2017-09-01

    Great interest has been directed towards the use of first-void urine as a liquid biopsy for high-risk human papillomavirus DNA testing. Despite the high correlations established between urinary and cervical infections, human papillomavirus testing is unable to distinguish between productive and transforming high-risk infections that have the tendency to progress to cervical cancer. Thus far, investigations have been primarily confined to the identification of biomarkers for triage of high-risk human papillomavirus-positive women in cervicovaginal specimens and tissue biopsies. This paper reviews urinary biomarkers for cervical cancer and triage of high-risk human papillomavirus infections and elaborates on the opportunities and challenges that have emerged regarding the use of first-void urine as a liquid biopsy for the analysis of both morphological- (conventional cytology and novel immunohistochemical techniques) and molecular-based (HPV16/18 genotyping, host/viral gene methylation, RNA, and proteins) biomarkers. A literature search was performed in PubMed and Web of Science for studies investigating the use of urine as a biomarker source for cervical cancer screening. Five studies were identified reporting on biomarkers that are still in preclinical exploratory or clinical assay development phases and on assessments of non-invasive (urine) samples. Although large-scale validation studies are still needed, we conclude that methylation of both host and viral genes in urine has been proven feasible for use as a molecular cervical cancer triage and screening biomarker in phase two studies. This is especially promising and underscores our hypothesis that human papillomavirus DNA and candidate human and viral biomarkers are washed away with the initial, first-void urine, together with exfoliated cells, debris and impurities that line the urethra opening. Similar to the limitations of self-collected cervicovaginal samples, first-void urine will likely not fulfil the high-quality cellularity standards required for morphological biomarkers. Molecular biomarkers will likely overcome this issue to yield high-throughput, objective, and reproducible results. When using proper sampling, transport, storage, preanalytical biomarker concentration techniques, and clinically validated assays, first-void urine is expected to be a valuable source of molecular biomarkers for cervical cancer screening. Furthermore, as first-void urine can be easily and non-invasively collected, it is a highly preferred technique among women and offers the ability to test both primary high-risk human papillomavirus and biomarkers in the same sample. In addition, the use of first-void urine confers opportunities to reduce loss-to follow-up and non-adherence to screening subjects. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  7. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Rodriguez, Branelle R.; Broyan, James Lee, Jr.

    2008-01-01

    Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.

  8. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Cibuzar, Branelle R.; Broyan, James Lee, Jr.

    2009-01-01

    Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.

  9. 1-Hydroxypyrene concentrations in first morning voids and 24-h composite urine: intra- and inter-individual comparisons.

    PubMed

    Han, In-Kyu; Duan, Xiaoli; Zhang, Lin; Yang, Hongbiao; Rhoads, George G; Wei, Fusheng; Zhang, Junfeng

    2008-09-01

    Urinary 1-hydroxypyrene (1-OHP) has been suggested as an exposure biomarker for polycyclic aromatic hydrocarbons (PAHs). However, it remains unknown whether a first morning urine sample can be used to reflect average exposure. In this paper, we examine intra-individual differences and inter-individual associations between first morning voids and 24-h composite urine samples. The analysis was performed using data collected from 100 adults who had a wide range of PAH exposure due to differences in their occupation, e.g., coke oven workers vs. non-coke oven workers. For each subject, all the urine voids within each of two 24-h measurement periods were collected. Results showed a significant (40% to 62%) intra-individual difference between first morning voids and 24-h urinary 1-OHP concentrations (in ng/ml urine). Creatinine adjustments of 1-OHP concentrations (in micromol/mol urinary creatinine) reduced the intra-individual difference by approximately 10%. Across all the subjects, a high overall correlation (r=0.76) was observed between first morning and 24-h average 1-OHP concentrations. Work environment and sampling season were found to significantly affect the relationship between first morning and 24-h 1-OHP concentrations. An increase of 1 ng/ml of first morning urinary 1-OHP predicted an increase of 0.5 and 0.25 ng/ml of 24-h urinary 1-OHP for coke oven workers and non-coke oven workers, respectively. Data collected in a winter season showed a higher correlation between first morning and 24-h concentrations than data collected in a fall season. Creatinine adjustments did not significantly improve overall correlations between first morning void and 24-h measurements, but increased total variances for 24-h urines explained by first morning urines in coke workers.

  10. Adequacy in voided urine cytology specimens: The role of volume and a repeat void upon predictive values for high-grade urothelial carcinoma.

    PubMed

    VandenBussche, Christopher J; Rosenthal, Dorothy L; Olson, Matthew T

    2016-03-01

    Adequacy assessment is one of the most controversial and overlooked components in the daily practice of cytopathology, because it is generally determined from limited samples. Because voided urine varies widely in terms of its volume and cellularity, there is little consensus about the proper role for these variables in assessing specimen adequacy. In this study, the authors explored the role of volume in voided urine specimens to determine whether it plays a role in determining adequacy for the detection of high-grade urothelial carcinoma. Voided urine specimens received at the authors' laboratory over the 9.5 years since the introduction of the Johns Hopkins Template for Reporting Urinary Cytopathology were analyzed for correlations between volume, specimen adequacy, and the diagnosis of high-grade malignancy. The same data set also was queried to determine whether a patient who provided a voided low-volume specimen could yield a higher volume specimen and thereby increase adequacy. In total, 15,731 voided urine specimens with a cumulative volume of 891 liters originating from 8594 individual patients were analyzed. Specimen adequacy increased linearly for each increment of volume submitted to the laboratory up to 30 mL, after which the correlation was nonlinear. Low-volume specimens below this cutoff also had lower fractions of specimens that were diagnosed as malignant or suspicious. Volume is an important component in the evaluation of adequacy for voided urine cytology specimens. © 2015 American Cancer Society.

  11. Stability and reproducibility of a single-sample urinary C-peptide/creatinine ratio and its correlation with 24-h urinary C-peptide.

    PubMed

    McDonald, Tim J; Knight, Bridget A; Shields, Beverley M; Bowman, Pamela; Salzmann, Maurice B; Hattersley, Andrew T

    2009-11-01

    C-peptide measurement in blood or 24-h urine samples provides useful information regarding endogenous insulin secretion, but problems related to the rapid degradation of C-peptide in blood and difficulty of 24-h urine collection have limited widespread routine clinical use of this test. We assessed the feasibility of measuring urinary C-peptide (UCP) with correction for creatinine concentration in single urine samples. We analyzed UCP using a routine electrochemiluminescence immunoassay in samples from 21 healthy volunteers. We investigated the stability of UCP with different preservatives and storage conditions and compared the reproducibility of urinary C-peptide/creatinine ratio (UCPCR) in first- and second-void fasting urines, then assessed correlations with 24-h collections. UCPCR was unchanged at room temperature for 24 h and at 4 degrees C for 72 h even in the absence of preservative. UCPCR collected in boric acid was stable at room temperature for 72 h. UCPCR remained stable after 7 freeze-thaw cycles but decreased with freezer storage time and dropped to 82%-84% of baseline by 90 days at -20 degrees C. Second-void fasting UCPCRs were lower than first-void (median 0.78 vs 1.31, P = 0.0003) and showed less variation (CV 33% vs 52%), as second-void UCPCRs were not influenced by evening food-related insulin secretion. Second-void fasting UCPCR was highly correlated with 24-h UCP (r = 0.8, P = 0.00006). Second-void fasting UCPCR is a reproducible measure that correlates well with 24-h UCP in normal samples. The 3-day stability of UCPCR at room temperature greatly increases its potential clinical utility.

  12. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Urine data set contains analytical results for measurements of up to 7 metals in 86 urine samples over 86 households. Each sample was collected from the primary respondent within each household. The sample consists of the first morning void following the 24-hour d...

  13. Optimization of HPV DNA detection in urine by improving collection, storage, and extraction.

    PubMed

    Vorsters, A; Van den Bergh, J; Micalessi, I; Biesmans, S; Bogers, J; Hens, A; De Coster, I; Ieven, M; Van Damme, P

    2014-11-01

    The benefits of using urine for the detection of human papillomavirus (HPV) DNA have been evaluated in disease surveillance, epidemiological studies, and screening for cervical cancers in specific subgroups. HPV DNA testing in urine is being considered for important purposes, notably the monitoring of HPV vaccination in adolescent girls and young women who do not wish to have a vaginal examination. The need to optimize and standardize sampling, storage, and processing has been reported.In this paper, we examined the impact of a DNA-conservation buffer, the extraction method, and urine sampling on the detection of HPV DNA and human DNA in urine provided by 44 women with a cytologically normal but HPV DNA-positive cervical sample. Ten women provided first-void and midstream urine samples. DNA analysis was performed using real-time PCR to allow quantification of HPV and human DNA.The results showed that an optimized method for HPV DNA detection in urine should (a) prevent DNA degradation during extraction and storage, (b) recover cell-free HPV DNA in addition to cell-associated DNA, (c) process a sufficient volume of urine, and (d) use a first-void sample.In addition, we found that detectable human DNA in urine may not be a good internal control for sample validity. HPV prevalence data that are based on urine samples collected, stored, and/or processed under suboptimal conditions may underestimate infection rates.

  14. NHEXAS PHASE I MARYLAND STUDY--METALS IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Urine data set contains analytical results for measurements of up to 3 metals in 376 urine samples over 80 households. Each sample was collected from the primary respondent within each household during the study and represented the first morning void of either Day ...

  15. Variability of collagen crosslinks: impact of sample collection period

    NASA Technical Reports Server (NTRS)

    Smith, S. M.; Dillon, E. L.; DeKerlegand, D. E.; Davis-Street, J. E.

    2004-01-01

    Because of the variability of collagen crosslinks, their use as markers for bone resorption is often criticized. We hypothesized that the variability could be reduced by collecting urine for 24 hours (or longer) instead of using single voids, and by not normalizing to creatinine. Urine samples were collected from 22 healthy subjects during two or more 24-hour periods. Each 24-hour pool and each 2nd void of the day were analyzed for N-telopeptide (NTX), pyridinium (PYD), and deoxypyridinoline (DPD) crosslinks. Data were analyzed by using linear regression. For NTX, R2 for the two, 2nd-void samples (n = 38) was 0.55, whereas R2 for the two 24-hour pools was 0.51 or 0.52, expressed per day or per creatinine. For PYD and DPD, R2 for the 2nd-void samples was 0.26 and 0.18, R2 for the 24-hour pools expressed per day was 0.58 and 0.74, and R2 for the 24-hour pools expressed per creatinine was 0.65 and 0.76, respectively. Regression of the 2nd void and the corresponding 24-hour pool, expressed per day, yielded R2 = 0.19, 0.19, and 0.08, for NTX, PYD, and DPD, respectively (n = 76 each). For the 2nd-void sample and its corresponding 24-hour pool, expressed per creatinine, R2 = 0.24, 0.33, and 0.08, respectively. In a separate study, the coefficient of variation for NTX was reduced (P < 0.05) when data from more than one 24-hour collection were combined. Thus, the variability inherent in crosslink determinations can be reduced by collecting urine for longer periods. In research studies, the high variability of single-void collections, compounded by creatinine normalization, may alter or obscure findings.

  16. Pre-analytical Factors Influence Accuracy of Urine Spot Iodine Assessment in Epidemiological Surveys.

    PubMed

    Doggui, Radhouene; El Ati-Hellal, Myriam; Traissac, Pierre; El Ati, Jalila

    2018-03-26

    Urinary iodine concentration (UIC) is commonly used to assess iodine status of subjects in epidemiological surveys. As pre-analytical factors are an important source of measurement error and studies about this phase are scarce, our objective was to assess the influence of urine sampling conditions on UIC, i.e., whether the child ate breakfast or not, urine void rank of the day, and time span between last meal and urine collection. A nationwide, two-stage, stratified, cross-sectional study including 1560 children (6-12 years) was performed in 2012. UIC was determined by the Sandell-Kolthoff method. Pre-analytical factors were assessed from children's mothers by using a questionnaire. Association between iodine status and pre-analytical factors were adjusted for one another and socio-economic characteristics by multivariate linear and multinomial regression models (RPR: relative prevalence ratios). Skipping breakfast prior to morning urine sampling decreased UIC by 40 to 50 μg/L and the proportion of UIC < 100 μg/L was higher among children having those skipped breakfast (RPR = 3.2[1.0-10.4]). In unadjusted analyses, UIC was less among children sampled more than 5 h from their last meal. UIC decreased with rank of urine void (e.g., first vs. second, P < 0.001); also, the proportion of UIC < 100 μg/L was greater among 4th rank samples (vs. second RPR = 2.1[1.1-4.0]). Subjects' breakfast status and urine void rank should be accounted for when assessing iodine status. Providing recommendations to standardize pre-analytical factors is a key step toward improving accuracy and comparability of survey results for assessing iodine status from spot urine samples. These recommendations have to be evaluated by future research.

  17. Primary health care providers surveyed commonly misinterpret 'first void urine' for chlamydia screening.

    PubMed

    Lusk, M Josephine; Uddin, Ruby; Ferson, Mark; Rawlinson, William; Konecny, Pam

    2009-03-01

    An open question survey of general practitioners (GP) and hospital emergency department (ED) doctors revealed that the term 'FVU' (first void urine) used for urine chlamydia testing, is ambiguous, potentially leading to incorrect urine sample collection and barriers to effective screening. The results of this survey indicate that only 4.3% (95% confidence interval [CI] 0.5-14.5%) of GP and 6.9% (95% CI 0.9-22.8%) of ED doctors respectively, correctly interpreted the meaning of FVU. The majority of clinicians surveyed misunderstood 'FVU' to require the first urine void of the day, accounting for 68.1% (95% CI 52.9-80.9%) of GP responses and 37.9% (95% CI 20.7-57.7%) of ED doctors responses. This highlights the need for clarification and standardisation of terminology used in urine chlamydia screening for health care providers, in order to optimise strategies for diagnosis and control of the ongoing chlamydia epidemic.

  18. Spectrophotometric photodynamic detection involving extracorporeal treatment with hexaminolevulinate for bladder cancer cells in voided urine.

    PubMed

    Nakai, Yasushi; Ozawa, Toshiyuki; Mizuno, Fumiko; Onishi, Sayuri; Owari, Takuya; Hori, Syunta; Morizawa, Yosuke; Tatsumi, Yosihiro; Miyake, Makito; Tanaka, Nobumichi; Tsuruta, Daisuke; Fujimoto, Kiyohide

    2017-11-01

    To evaluate the feasibility of hexaminolevulinate (HAL) for the photodynamic detection of cancer cells in voided urine. This study included 50 patients with bladder cancer that was confirmed histologically after transurethral resection (bladder cancer group) and 50 outpatients without a history of urothelial carcinoma or cancer-related findings (no malignancy group). One third of the voided urine samples were incubated with aminolevulinic acid (ALA-treated samples), one third were incubated with HAL (HAL-treated samples), and the remaining samples were incubated without treatment (untreated samples). For detecting cellular protoporphyrin IX levels, the intensity of the samples at the excitation wavelength of 405 nm was measured using a spectrophotometer. The difference between the intensity of the ALA-treated or HAL-treated samples and the untreated samples at 635 nm was calculated. HAL-induced fluorescence cytology (HFC) showed that the difference was significantly higher in patients with high-grade tumors than in those with low-grade tumors (p = 0.0003) and the difference was significantly higher in patients with low-grade tumors than in those without a history of urothelial carcinoma or cancer-related findings (p = 0.021). The areas under the receiver operating characteristic curves of ALA-induced fluorescence cytology (AFC) and HFC were 0.77 and 0.81, respectively. The AUC of HFC was significantly higher than that of AFC (p < 0.0001). The overall sensitivity values for conventional cytology, AFC, and HFC were 49, 74, and 74%, respectively. The overall specificity values for AFC and HFC were 70 and 94%, respectively. Spectrophotometric photodynamic detection involving extracorporeal treatment with HAL for bladder cancer cells in voided urine showed high accuracy. This bladder cancer detection method is easy and cost-effective, and has the potential for clinical use.

  19. Accuracy of urinary human papillomavirus testing for presence of cervical HPV: systematic review and meta-analysis

    PubMed Central

    Pathak, Neha; Dodds, Julie; Khan, Khalid

    2014-01-01

    Objective To determine the accuracy of testing for human papillomavirus (HPV) DNA in urine in detecting cervical HPV in sexually active women. Design Systematic review and meta-analysis. Data sources Searches of electronic databases from inception until December 2013, checks of reference lists, manual searches of recent issues of relevant journals, and contact with experts. Eligibility criteria Test accuracy studies in sexually active women that compared detection of urine HPV DNA with detection of cervical HPV DNA. Data extraction and synthesis Data relating to patient characteristics, study context, risk of bias, and test accuracy. 2×2 tables were constructed and synthesised by bivariate mixed effects meta-analysis. Results 16 articles reporting on 14 studies (1443 women) were eligible for meta-analysis. Most used commercial polymerase chain reaction methods on first void urine samples. Urine detection of any HPV had a pooled sensitivity of 87% (95% confidence interval 78% to 92%) and specificity of 94% (95% confidence interval 82% to 98%). Urine detection of high risk HPV had a pooled sensitivity of 77% (68% to 84%) and specificity of 88% (58% to 97%). Urine detection of HPV 16 and 18 had a pooled sensitivity of 73% (56% to 86%) and specificity of 98% (91% to 100%). Metaregression revealed an increase in sensitivity when urine samples were collected as first void compared with random or midstream (P=0.004). Limitations The major limitations of this review are the lack of a strictly uniform method for the detection of HPV in urine and the variation in accuracy between individual studies. Conclusions Testing urine for HPV seems to have good accuracy for the detection of cervical HPV, and testing first void urine samples is more accurate than random or midstream sampling. When cervical HPV detection is considered difficult in particular subgroups, urine testing should be regarded as an acceptable alternative. PMID:25232064

  20. Estimating the population distribution of usual 24-hour sodium excretion from timed urine void specimens using a statistical approach accounting for correlated measurement errors.

    PubMed

    Wang, Chia-Yih; Carriquiry, Alicia L; Chen, Te-Ching; Loria, Catherine M; Pfeiffer, Christine M; Liu, Kiang; Sempos, Christopher T; Perrine, Cria G; Cogswell, Mary E

    2015-05-01

    High US sodium intake and national reduction efforts necessitate developing a feasible and valid monitoring method across the distribution of low-to-high sodium intake. We examined a statistical approach using timed urine voids to estimate the population distribution of usual 24-h sodium excretion. A sample of 407 adults, aged 18-39 y (54% female, 48% black), collected each void in a separate container for 24 h; 133 repeated the procedure 4-11 d later. Four timed voids (morning, afternoon, evening, overnight) were selected from each 24-h collection. We developed gender-specific equations to calibrate total sodium excreted in each of the one-void (e.g., morning) and combined two-void (e.g., morning + afternoon) urines to 24-h sodium excretion. The calibrated sodium excretions were used to estimate the population distribution of usual 24-h sodium excretion. Participants were then randomly assigned to modeling (n = 160) or validation (n = 247) groups to examine the bias in estimated population percentiles. Median bias in predicting selected percentiles (5th, 25th, 50th, 75th, 95th) of usual 24-h sodium excretion with one-void urines ranged from -367 to 284 mg (-7.7 to 12.2% of the observed usual excretions) for men and -604 to 486 mg (-14.6 to 23.7%) for women, and with two-void urines from -338 to 263 mg (-6.9 to 10.4%) and -166 to 153 mg (-4.1 to 8.1%), respectively. Four of the 6 two-void urine combinations produced no significant bias in predicting selected percentiles. Our approach to estimate the population usual 24-h sodium excretion, which uses calibrated timed-void sodium to account for day-to-day variation and covariance between measurement errors, produced percentile estimates with relatively low biases across low-to-high sodium excretions. This may provide a low-burden, low-cost alternative to 24-h collections in monitoring population sodium intake among healthy young adults and merits further investigation in other population subgroups. © 2015 American Society for Nutrition.

  1. Comparison between Urine and Cervical Samples for HPV DNA Detection and Typing in Young Women in Colombia.

    PubMed

    Cómbita, Alba Lucía; Gheit, Tarik; González, Paula; Puerto, Devi; Murillo, Raúl Hernando; Montoya, Luisa; Vorsters, Alex; Van Keer, Severien; Van Damme, Pierre; Tommasino, Massimo; Hernández-Suárez, Gustavo; Sánchez, Laura; Herrero, Rolando; Wiesner, Carolina

    2016-09-01

    Urine sampling for HPV DNA detection has been proposed as an effective method for monitoring the impact of HPV vaccination programs; however, conflicting results have been reported. The goal of this study was to evaluate the performance of optimized urine HPV DNA testing in women aged 19 to 25 years. Optimization process included the use of first void urine, immediate mixing of urine with DNA preservative, and the concentration of all HPV DNA, including cell-free DNA fragments. Urine and cervical samples were collected from 535 young women attending cervical screening at health centers from two Colombian cities. HPV DNA detection and genotyping was performed using an HPV type-specific multiplex genotyping assay, which combines multiplex polymerase chain reaction with bead-based Luminex technology. Concordance between HPV DNA detection in urine and cervical samples was determined using kappa statistics and McNemar tests. The accuracy of HPV DNA testing in urine samples was evaluated measuring sensitivity and specificity using as reference the results obtained from cervical samples. Statistical analysis was performed using STATA11.2 software. The findings revealed an overall HPV prevalence of 60.00% in cervical samples and 64.72% in urine samples, HPV-16 being the most frequent HPV type detected in both specimens. Moreover, our results indicate that detection of HPV DNA in first void urine provides similar results to those obtained with cervical samples and can be used to monitor HPV vaccination trials and programs as evidenced by the substantial concordance found for the detection of the four vaccine types. Cancer Prev Res; 9(9); 766-71. ©2016 AACR. ©2016 American Association for Cancer Research.

  2. Gene expression signature in urine for diagnosing and assessing aggressiveness of bladder urothelial carcinoma.

    PubMed

    Mengual, Lourdes; Burset, Moisès; Ribal, María José; Ars, Elisabet; Marín-Aguilera, Mercedes; Fernández, Manuel; Ingelmo-Torres, Mercedes; Villavicencio, Humberto; Alcaraz, Antonio

    2010-05-01

    To develop an accurate and noninvasive method for bladder cancer diagnosis and prediction of disease aggressiveness based on the gene expression patterns of urine samples. Gene expression patterns of 341 urine samples from bladder urothelial cell carcinoma (UCC) patients and 235 controls were analyzed via TaqMan Arrays. In a first phase of the study, three consecutive gene selection steps were done to identify a gene set expression signature to detect and stratify UCC in urine. Subsequently, those genes more informative for UCC diagnosis and prediction of tumor aggressiveness were combined to obtain a classification system of bladder cancer samples. In a second phase, the obtained gene set signature was evaluated in a routine clinical scenario analyzing only voided urine samples. We have identified a 12+2 gene expression signature for UCC diagnosis and prediction of tumor aggressiveness on urine samples. Overall, this gene set panel had 98% sensitivity (SN) and 99% specificity (SP) in discriminating between UCC and control samples and 79% SN and 92% SP in predicting tumor aggressiveness. The translation of the model to the clinically applicable format corroborates that the 12+2 gene set panel described maintains a high accuracy for UCC diagnosis (SN = 89% and SP = 95%) and tumor aggressiveness prediction (SN = 79% and SP = 91%) in voided urine samples. The 12+2 gene expression signature described in urine is able to identify patients suffering from UCC and predict tumor aggressiveness. We show that a panel of molecular markers may improve the schedule for diagnosis and follow-up in UCC patients. Copyright 2010 AACR.

  3. Temporal variability of urinary cadmium in spot urine samples and first morning voids.

    PubMed

    Vacchi-Suzzi, Caterina; Porucznik, Christina A; Cox, Kyley J; Zhao, Yuan; Ahn, Hongshik; Harrington, James M; Levine, Keith E; Demple, Bruce; Marsit, Carmen J; Gonzalez, Adam; Luft, Benjamin; Meliker, Jaymie R

    2017-05-01

    Cadmium is a carcinogenic heavy metal. Urinary levels of cadmium are considered to be an indicator of long-term body burden, as cadmium accumulates in the kidneys and has a half-life of at least 10 years. However, the temporal stability of the biomarker in urine samples from a non-occupationally exposed population has not been rigorously established. We used repeated measurements of urinary cadmium (U-Cd) in spot urine samples and first morning voids from two separate cohorts, to assess the temporal stability of the samples. Urine samples from two cohorts including individuals of both sexes were measured for cadmium and creatinine. The first cohort (Home Observation of Perinatal Exposure (HOPE)) consisted of 21 never-smokers, who provided four first morning urine samples 2-5 days apart, and one additional sample roughly 1 month later. The second cohort (World Trade Center-Health Program (WTC-HP)) consisted of 78 individuals, including 52 never-smokers, 22 former smokers and 4 current smokers, who provided 2 spot urine samples 6 months apart, on average. Intra-class correlation was computed for groups of replicates from each individual to assess temporal variability. The median creatinine-adjusted U-Cd level (0.19 and 0.21 μg/g in the HOPE and WTC-HP, respectively) was similar to levels recorded in the United States by the National Health and Nutrition Examination Survey. The intra-class correlation (ICC) was high (0.76 and 0.78 for HOPE and WTC-HP, respectively) and similar between cohorts, irrespective of whether samples were collected days or months apart. Both single spot or first morning urine cadmium samples show good to excellent reproducibility in low-exposure populations.

  4. Atypical cells in a voided urine cytology specimen in a renal transplant recipient.

    PubMed

    Lu, Miao; Ho, Julie; Azordegan, Nazila; Perry, Anamarija M; Gibson, Ian W; Baker, Patricia

    2017-01-01

    Voided urine is routinely collected from renal transplant patients to screen for polyomavirus. In rare cases, atypical lymphoid cells can be detected in voided urine and raise the suspicion of post-transplant lymphoproliferative disorder (PTLD). However, further immunohistochemistry of the cell block and flow cytometry is frequently limited by the low cellularity and poor preservation of voided urine. Therefore, PTLD of the renal allograft is usually diagnosed from tissue biopsy or nephrectomy specimens. Herein, we report a rare case of atypical cells in a voided urine cytology specimen from a kidney transplant recipient. Needle core biopsy of the renal allograft showed monomorphic PTLD. Diagn. Cytopathol. 2017;45:69-72. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  5. Extraintestinal Complications: Kidney Disorders

    MedlinePlus

    ... the ureters, bladder, and urethra for the passage, storage, and voiding of urine. Serious kidney complications associated with IBD are rare, ... Proteinuria, an elevated level of protein in the urine, is one sign of amyloidosis. A biopsy (tissue sample) of the kidney can confirm the diagnosis. Various ...

  6. Comparison of urine specimen collection times and testing fractions for the detection of high-risk human papillomavirus and high-grade cervical precancer.

    PubMed

    Senkomago, V; Des Marais, A C; Rahangdale, L; Vibat, C R T; Erlander, M G; Smith, J S

    2016-01-01

    Urine testing for high-risk human papillomavirus (HR-HPV) detection could provide a non-invasive, simple method for cervical cancer screening. We examined whether HR-HPV detection is affected by urine collection time, portion of urine stream, or urine fraction tested, and assessed the performance of HR-HPV testing in urine for detection of cervical intraepithelial neoplasia grade II or worse (CIN2+). A total of 37 female colposcopy clinic attendees, ≥ 30 years, provided three urine samples: "first void" urine collected at home, and "initial stream" and "mid-stream" urine samples collected at the clinic later in the day. Self- and physician-collected brush specimens were obtained at the same clinic visit. Colposcopy was performed and directed biopsies obtained if clinically indicated. For each urine sample, HR-HPV DNA testing was conducted for unfractionated, pellet, and supernatant fractions using the Trovagene test. HR-HPV mRNA testing was performed on brush specimens using the Aptima HPV assay. HR-HPV prevalence was similar in unfractionated and pellet fractions of all urine samples. For supernatant urine fractions, HR-HPV prevalence appeared lower in mid-stream urine (56.8%[40.8-72.7%]) than in initial stream urine (75.7%[61.9-89.5%]). Sensitivity of CIN2+ detection was identical for initial stream urine and physician-collected cervical specimen (89.9%[95%CI=62.7-99.6%]), and similar to self-collected vaginal specimen (79.1%[48.1-96.6%]). This is among the first studies to compare methodologies for collection and processing of urine for HR-HPV detection. HR-HPV prevalence was similar in first void and initial stream urine, and was highly sensitive for CIN2+ detection. Additional research in a larger and general screening population is needed. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. The International Space Station Urine Monitoring System (UMS)

    NASA Technical Reports Server (NTRS)

    Feeback, Daniel L.; Cibuzar, Branelle R.; Milstead, Jeffery R.; Pietrzyk,, Robert A.; Clark, Mark S.F.

    2009-01-01

    A device capable of making in-flight volume measurements of single void urine samples, the Urine Monitoring System (UMS), was developed and flown on seven U.S. Space Shuttle missions. This device provided volume data for each urine void from multiple crewmembers and allowed samples of each to be taken and returned to Earth for post-flight analysis. There were a number of design flaws in the original instrument including the presence of liquid carry-over producing invalid "actual" micturition volumes and cross-contamination between successive users from residual urine in "dead" spots". Additionally, high or low volume voids could not be accurately measured, the on-orbit calibration and nominal use sequence was time intensive, and the unit had to be returned and disassembled to retrieve the volume data. These problems have been resolved in a new version, the International Space Station (ISS) UMS, that has been designed to provide real-time in-flight volume data with accuracy and precision equivalent to measurements made on Earth and the ability to provide urine samples that are unadulterated by the device. Originally conceived to be interfaced with a U.S.-built Waste Collection System (WCS), the unit now has been modified to interface with the Russian-supplied Sanitary Hygiene Device (ASY). The ISS UMS provides significant advantages over the current method of collecting urine samples into Urine Collection Devices (UCDs), from which samples are removed and returned to Earth for analyses. A significant future advantage of the UMS is that it can provide an interface to analytical instrumentation that will allow real-time measurement of urine bioanalytes allowing monitoring of crewmember health status during flight and the ability to provide medical interventions based on the results of these measurements. Currently, the ISS UMS is scheduled to launch along with Node-3 on STS-130 (20A) in December 2009. UMS will be installed and scientific/functional verification completed prior to placing the instrument into operation. Samples collected during the verification sequence will be returned for analyses on STS-131 (19A) currently scheduled for launch in March 2010. The presence of a UMS on ISS will provide the capability to conduct additional collaborative human life science investigations among the ISS International Partners.

  8. Simultaneous immunostaining with anti-S100P and anti-SV40 antibodies revealed the origin of BK virus-infected decoy cells in voided urine samples.

    PubMed

    Ariyasu, S; Yanai, H; Sato, M; Shinno, Y; Taniguchi, K; Yamadori, I; Miki, Y; Sato, Y; Yoshino, T; Takahashi, K

    2015-08-01

    Methods for determining the origin of BK virus (BKV)-infected cells (decoy cells) in clinical urine samples have not been established although they could enhance the diagnosis of BKV infection in immunocompromised patients. We performed simultaneous immunostaining with anti-S100P (a urothelial marker) and anti-SV40 antibodies in 66 clinical urine samples exhibiting SV40 positivity and a decoy-cell appearance on Papanicolaou staining. The clinical voided urine samples included seven cases of renal transplantation, 47 cases of cancer therapy and 12 cases of non-neoplastic disease. SurePath(™) liquid-based cytology was used for the urine samples. BKV-infected cells were categorized as SV40(+)/S100P(+) and SV40 (+)/S100p(-). SV40(+)/S100P(-) cells were found in 55 cases (83.4%); nine cases (13.6%) carried both SV40(+)/S100P(-) and SV40(+)/S100P(+) cells. The former were identified as BKV infection in renal tubules and the latter in both the renal tubules and urothelial epithelia. The remaining two cases (3.0%) had only SV40(+)/S100P(+) cells of urothelial origin. Simultaneous immunostaining with anti-S100P and anti-SV40 is a useful method for determining the origin of BKV-infected cells in clinical urine samples from immunocompromised patients such as renal transplantation recipients. © 2014 John Wiley & Sons Ltd.

  9. Chemical Method of Urine Volume Measurement

    NASA Technical Reports Server (NTRS)

    Petrack, P.

    1967-01-01

    A system has been developed and qualified as flight hardware for the measurement of micturition volumes voided by crewmen during Gemini missions. This Chemical Urine Volume Measurement System (CUVMS) is used for obtaining samples of each micturition for post-flight volume determination and laboratory analysis for chemical constituents of physiological interest. The system is versatile with respect to volumes measured, with a capacity beyond the largest micturition expected to be encountered, and with respect to mission duration of inherently indefinite length. The urine sample is used for the measurement of total micturition volume by a tracer dilution technique, in which a fixed, predetermined amount of tritiated water is introduced and mixed into the voided urine, and the resulting concentration of the tracer in the sample is determined with a liquid scintillation spectrometer. The tracer employed does not interfere with the analysis for the chemical constituents of the urine. The CUVMS hardware consists of a four-way selector valve in which an automatically operated tracer metering pump is incorporated, a collection/mixing bag, and tracer storage accumulators. The assembled system interfaces with a urine receiver at the selector valve inlet, sample bags which connect to the side of the selector valve, and a flexible hose which carries the excess urine to the overboard drain connection. Results of testing have demonstrated system volume measurement accuracy within the specification limits of +/-5%, and operating reliability suitable for system use aboard the GT-7 mission, in which it was first used.

  10. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Rodriquez, Branelle R.; Broyan, James Lee, Jr.

    2011-01-01

    Exposure to microgravity during human spaceflight needs to be better understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Measuring the calcium and other metabolic byproducts in a crew member s urine can evaluate the effectiveness of bone loss countermeasures. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross-contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross-contamination (<0.7 mL urine) and has volume accuracy of 2% between 100 to 1000 mL urine voids. Designed to provide a non-invasive means to collect urine samples from crew members, the ISS UMS operates in-line with the Node 3 Waste and Hygiene Compartment (WHC). The ISS UMS has undergone modifications required to interface with the WHC, including material changes, science algorithm improvements, and software platform revisions. Integrated functional testing was performed to determine the pressure drop, air flow rate, and the maximum amount of fluid capable of being discharged from the UMS to the WHC. This paper will detail the results of the science and the functional integration tests.

  11. Chemical differences between voided and bladder urine in the aye-aye (Daubentonia madagascariensis): implications for olfactory communication studies.

    PubMed

    Delbarco-Trillo, Javier; Harelimana, Innocent H; Goodwin, Thomas E; Drea, Christine M

    2013-07-01

    Urine serves a communicative function in many mammalian species. In some species, the signaling function of urine can be enhanced by the addition of chemical compounds from glands along the distal portion of the urogenital tract. Although urine marking is the main mode of chemical communication in many primate species, there has been no study of the contribution of urogenital secretions to the chemical complexity of primate urine. Here, we compared the chemical composition of bladder urine versus voided urine in the aye-aye, Daubentonia madagascariensis, a strepsirrhine primate that relies on urine in intraspecific communication. Both types of urine, collected from each of 11 aye-ayes representing both sexes of varying adult ages, underwent headspace analysis via gas chromatography and mass spectrometry. Although the average number of compounds was similar in bladder and voided urine, 17% of the compounds detected occurred exclusively in voided urine (but only in a subset of individuals). An overall measure of chemical complexity (using a nonmetric multidimensional scaling analysis) showed that both types of urine were chemically different at the individual level. There was no apparent sex or age differences in the chemical components found in aye-aye urine. Nonetheless, the individual dissimilarities between bladder urine and voided urine indicate chemical contributions from structures along the urogenital tract and offer further support for the relevance of urinary communication in the aye-aye. © 2012 Wiley Periodicals, Inc.

  12. Requirement for specific gravity and creatinine adjustments for urinary steroids and luteinizing hormone concentrations in adolescents.

    PubMed

    Singh, Gurmeet K S; Balzer, Ben W R; Desai, Reena; Jimenez, Mark; Steinbeck, Katharine S; Handelsman, David J

    2015-11-01

    Urinary hormone concentrations are often adjusted to correct for hydration status. We aimed to determine whether first morning void urine hormones in growing adolescents require adjustments and, if so, whether urinary creatinine or specific gravity are better adjustments. The study population was adolescents aged 10.1 to 14.3 years initially who provided fasting morning blood samples at 0 and 12 months (n = 343) and first morning urine every three months (n = 644). Unadjusted, creatinine and specific gravity-adjusted hormonal concentrations were compared by Deming regression and Bland-Altman analysis and grouped according to self-rated Tanner stage or chronological age. F-ratios for self-rated Tanner stages and age groups were used to compare unadjusted and adjusted hormonal changes in growing young adolescents. Correlations of paired serum and urinary hormonal concentration of unadjusted and creatinine and specific gravity-adjusted were also compared. Fasting first morning void hormone concentrations correlated well and were unbiased between unadjusted or adjusted by either creatinine or specific gravity. Urine creatinine concentration increases with Tanner stages, age and male gender whereas urine specific gravity was not influenced by Tanner stage, age or gender. Adjustment by creatinine or specific gravity of urinary luteinizing hormone, estradiol, testosterone, dihydrotestosterone and dehydroepiandrosterone concentrations did not improve correlation with paired serum concentrations. Urine steroid and luteinizing hormone concentrations in first morning void samples of adolescents are not significantly influenced by hydration status and may not require adjustments; however, if desired, both creatinine and specific gravity adjustments are equally suitable. © The Author(s) 2015.

  13. Protoporphyrin IX induced by 5-aminolevulinic acid in bladder cancer cells in voided urine can be extracorporeally quantified using a spectrophotometer.

    PubMed

    Nakai, Yasushi; Anai, Satoshi; Onishi, Sayuri; Masaomi, Kuwada; Tatsumi, Yoshihiro; Miyake, Makito; Chihara, Yoshitomo; Tanaka, Nobumichi; Hirao, Yoshihiko; Fujimoto, Kiyohide

    2015-06-01

    We evaluated the feasibility of photodynamic diagnosis of bladder cancer by spectrophotometric analysis of voided urine samples after extracorporeal treatment with 5-aminolevulinic acid (ALA). Sixty-one patients with bladder cancer, confirmed histologically after the transurethral resection of a bladder tumor, were recruited as the bladder cancer group, and 50 outpatients without history of urothelial carcinoma or cancer-related findings were recruited as the control group. Half of the voided urine sample was incubated with ALA (ALA-treated sample), and the rest was incubated without treatment (ALA-untreated sample). For detecting cellular protoporphyrin IX levels, intensity of the samples at the excitation wavelength of 405 nm was measured using a spectrophotometer. The difference between the intensity of the ALA-treated and ALA-untreated samples at 635 nm was calculated. The differences in the bladder cancer group were significantly greater than those in the control group (p < 0.001). These differences were also significantly greater in patients with high-grade tumors than in those with low-grade tumors (p = 0.004), and also in patients with invasive bladder cancer than in those with noninvasive bladder cancer (p = 0.007). The area under the curve was 0.84. Sensitivity and specificity of the method were 82% and 80%, respectively. We demonstrated that protoporphyrin IX levels in urinary cells treated with ALA could be quantitatively detected by spectrophotometer in patients with bladder cancer. Therefore, this cancer detection system has a potential for clinical use. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Urinary ATP May Be a Dynamic Biomarker of Detrusor Overactivity in Women with Overactive Bladder Syndrome

    PubMed Central

    Oliveira, Olga; Ferreira, Sónia; Reis, Maria Júlia; Oliveira, José Carlos; Correia-de-Sá, Paulo

    2013-01-01

    Background Nowadays, there is a considerable bulk of evidence showing that ATP has a prominent role in the regulation of human urinary bladder function and in the pathophysiology of detrusor overactivity. ATP mediates nonadrenergic-noncholinergic detrusor contractions in overactive bladders. In vitro studies have demonstrated that uroepithelial cells and cholinergic nerves from overactive human bladder samples (OAB) release more ATP than controls. Here, we compared the urinary ATP concentration in samples collected non-invasively from OAB women with detrusor overactivity and age-matched controls. Methods Patients with neurologic diseases, history of malignancy, urinary tract infections or renal impairment (creatinine clearance <70 ml/min) were excluded. All patients completed a 3-day voiding diary, a 24 h urine collection and blood sampling to evaluate creatinine clearance. Urine samples collected during voluntary voids were immediately freeze-preserved for ATP determination by the luciferin-luciferase bioluminescence assay; for comparison purposes, samples were also tested for urinary nerve growth factor (NGF) by ELISA. Results The urinary content of ATP, but not of NGF, normalized to patients’ urine creatinine levels (ATP/Cr) or urinary volume (ATP.Vol) were significantly (P<0.05) higher in OAB women with detrusor overactivity (n = 34) than in healthy controls (n = 30). Significant differences between the two groups were still observed by boosting urinary ATP/Cr content after water intake, but these were not detected for NGF/Cr. In OAB patients, urinary ATP/Cr levels correlated inversely with mean voided volumes determined in a 3-day voiding diary. Conclusion A high area under the receiver operator characteristics (ROC) curve (0.741; 95% CI 0.62–0.86; P<0.001) is consistent with urinary ATP/Cr being a highly sensitive dynamic biomarker for assessing detrusor overactivity in women with OAB syndrome. PMID:23741373

  15. Collection fluid helps preservation in voided urine cytology.

    PubMed

    Raistrick, J; Shambayati, B; Dunsmuir, W

    2008-04-01

    Degenerative change caused by delay in processing contributes to false-negative and false-positive diagnosis of urothelial carcinoma in cytology. The aim of the study was to see if the use of a collection fluid for urine samples made a significant difference to urine cytology diagnosis, and if one was better suited for routine use in the hospital laboratory. Three cell collection fluids were evaluated by analysing the preservation and degeneration of cells in urine samples, as was the routine preparation which did not use a collection fluid. In the design study 50 voided urine specimens were taken at random from the hospital haematuria clinic. Three commercially available collection fluids cytolyt, cytospin and cytoRich Blue and the hospital's routine conventional preparation of urine were compared. The degree of degeneration, and so preservation, was assessed by a table of chosen criteria; then ranked and analysed by Friedman's nonparametric test, at P = 0.05. A second table showing the cell content of each slide was also made. These showed no significant diagnostic difference between the collection fluids, but there was a significant difference between the collection fluids and the routine preparation. Minor differences that do not affect diagnosis, such as crystals and ghost red blood cells, were noted in cytospin and cytoRich Blue. It is recommended that a collection fluid is used. This choice should be made after health and safety issues and cost are considered.

  16. Video Voiding Device for Diagnosing Lower Urinary Tract Dysfunction in Men.

    PubMed

    Shokoueinejad, Mehdi; Alkashgari, Rayan; Mosli, Hisham A; Alothmany, Nazeeh; Levin, Jacob M; Webster, John G

    2017-01-01

    We introduce a novel diagnostic Visual Voiding Device (VVD), which has the ability to visually document urinary voiding events and calculate key voiding parameters such as instantaneous flow rate. The observation of the urinary voiding process along with the instantaneous flow rate can be used to diagnose symptoms of Lower Urinary Tract Dysfunction (LUTD) and improve evaluation of LUTD treatments by providing subsequent follow-up documentations of voiding events after treatments. The VVD enables a patient to have a urinary voiding event in privacy while a urologist monitors, processes, and documents the event from a distance. The VVD consists of two orthogonal cameras which are used to visualize urine leakage from the urethral meatus, urine stream trajectory, and its break-up into droplets. A third, lower back camera monitors a funnel topped cylinder where urine accumulates that contains a floater for accurate readings regardless of the urine color. Software then processes the change in level of accumulating urine in the cylinder and the visual flow properties to calculate urological parameters. Video playback allows for reexamination of the voiding process. The proposed device was tested by integrating a mass flowmeter into the setup and simultaneously measuring the instantaneous flow rate of a predetermined voided volume in order to verify the accuracy of VVD compared to the mass flowmeter. The VVD and mass flowmeter were found to have an accuracy of ±2 and ±3% relative to full scale, respectively. A VVD clinical trial was conducted on 16 healthy male volunteers ages 23-65.

  17. MEASUREMENT OF CHILDREN'S EXPOSURE TO PESTICIDES: ANALYSIS OF URINARY METABOLITE LEVELS IN A PROBABILITY-BASED SAMPLE

    EPA Science Inventory

    The Minnesota Children's Pesticide Exposure Study is a probability-based sample of 102 children 3-13 years old who were monitored for commonly used pesticides. During the summer of 1997, first-morning-void urine samples (1-3 per child) were obtained for 88% of study children a...

  18. Variation in urinary spot sample, 24 h samples, and longer-term average urinary concentrations of short-lived environmental chemicals: implications for exposure assessment and reverse dosimetry

    PubMed Central

    Aylward, Lesa L; Hays, Sean M; Zidek, Angelika

    2017-01-01

    Population biomonitoring data sets such as the Canadian Health Measures Survey (CHMS) and the United States National Health and Nutrition Examination Survey (NHANES) collect and analyze spot urine samples for analysis for biomarkers of exposure to non-persistent chemicals. Estimation of population intakes using such data sets in a risk-assessment context requires consideration of intra- and inter-individual variability to understand the relationship between variation in the biomarker concentrations and variation in the underlying daily and longer-term intakes. Two intensive data sets with a total of 16 individuals with collection and measurement of serial urine voids over multiple days were used to examine these relationships using methyl paraben, triclosan, bisphenol A (BPA), monoethyl phthalate (MEP), and mono-2-ethylhexyl hydroxyl phthalate (MEHHP) as example compounds. Composited 24 h voids were constructed mathematically from the individual collected voids, and concentrations for each 24 h period and average multiday concentrations were calculated for each individual in the data sets. Geometric mean and 95th percentiles were compared to assess the relationship between distributions in spot sample concentrations and the 24 h and multiday collection averages. In these data sets, spot sample concentrations at the 95th percentile were similar to or slightly higher than the 95th percentile of the distribution of all 24 h composite void concentrations, but tended to overestimate the maximum of the multiday concentration averages for most analytes (usually by less than a factor of 2). These observations can assist in the interpretation of population distributions of spot samples for frequently detected analytes with relatively short elimination half-lives. PMID:27703149

  19. Factors affecting urine EIA sensitivity in the detection of Chlamydia trachomatis in men.

    PubMed Central

    Talbot, H; Romanowski, B

    1994-01-01

    OBJECTIVE--This study examined the effects of four variables on the detection of Chlamydia trachomatis in urine from men by enzyme immunoassay (EIA). These variables were: symptoms and signs of urethritis, urine polymorphonuclear leucocytes (PMN), inclusion counts from urethral chlamydia cell cultures and the time between testing and last voiding. METHODS--Included were patients with and without symptoms and/or signs of urethritis attending the Edmonton Sexually Transmitted Disease Clinic. Men were asked to submit a 20 ml volume urine sample. Urethral swabs were collected for gram stain, chlamydia and gonorrhea culture. RESULTS--A total of 318 men were evaluated of whom 47 had chlamydia. Excluding six men who were coinfected with gonorrhoea, sensitivities and specificities of the Microtrak, Chlamydiazyme and IDEIA systems were 78.1% and 99.6%, 75.6% and 100%, and 80.5% and 97.8% respectively. Last void time did not affect the sensitivity. However, sensitivity was best when applied to men with severe evidence of urethritis. CONCLUSION--There is evidence that urine EIA could be used to detect chlamydia in men with acute urethritis but not in those without signs of urethritis. PMID:8206466

  20. Convenient radioimmunoassay for urinary human choriogonadotropin without interference by urinary human lutropin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wehmann, R.E.; Harman, S.M.; Birken, S.

    1981-12-01

    We have devised a radioimmunoassay (RIA) for human choriogonadotropin (hCG) in first morning-voided urine specimens. Concanavalin A, a lectin, is used to extract and concentrate the hCG from urine. A high-affinity antiserum is used, directed to the hCG..beta.. carboxy-terminal peptide, a unique immunological determinant not shared by the beta subunit of human lutropin. This ensures that urinary human lutropin-related molecules, which interfere with RIAs involving antisera to the intact hCG..beta.. subunit, will not cross react in this assay. A concentration of hCG as low as 0.4 ..mu..g/L can be detected in the first morning-voided urine. The effective sensitivity of thismore » assay for the unequivocal detection of hCG production is somewhat better than that achieved with the serum hCG RIA involving antisera to the hCG..beta.. subunit. The improved specificity and sensitivity of this assay, and the greater convenience of collecting samples of urine rather than blood, are clinically useful advantages of this approach to assessing hCG production in humans.« less

  1. Increased risk of malignancy for non-atypical urothelial cell groups compared to negative cytology in voided urine. Morphological changes with LBC.

    PubMed

    Granados, Rosario; Butrón, Mercedes; Santonja, Carlos; Rodríguez, José-María; Martín, Ana; Duarte, Joanny; Camarmo, Encarnación; Corrales, Teresa; Aramburu, José-Antonio

    2016-07-01

    Liquid-based cytology (LBC) has recently become the preferred method for urine cytology analysis, but differences with conventional cytology (CC) have been observed. The purpose of this study is to analyze these differences and the clinical relevance of non-atypical urothelial cell groups (UCG) in voided urine specimens. Reporting terminology is discussed. Initially, diagnostic categories from 619 LBC and 474 CC samples, reviewed by five different pathologists, were compared (phase 1). Five years after LBC was implemented and applying strict cytologic criteria for UCG diagnosis, 760 samples were analyzed (phase 2) and compared to previous LBC specimens. Diagnostic differences, interobserver variability and clinicopathological correlation with a 6-month follow-up, were analyzed. UCG increased from 6.5% with CC to 20.7% (218%, 3.2 fold, P < 0.0001) with LBC. This difference was not related to interobserver variability. Five years later, the rate of UCG had decreased to 13 2%. While 6% of cases with a negative cytology had urothelial carcinoma (UC) within 6 months of diagnosis, this percentage increased to 15.7% with UCG. The sensitivity of the UCG category for UC was low (30.4%), but the specificity and the negative predictive value (NPV) were high (87.1% and 94%, respectively). LBC increases UCG when compared to CC. This can be corrected with observeŕs experience and using set cytological criteria. Due to its association with carcinoma, the presence of UCG in voided urine should be framed in a diagnostic category other than "negative for malignancy." Diagn. Cytopathol. 2016;44:582-590. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  2. Diversity of the midstream urine microbiome in adults with chronic kidney disease.

    PubMed

    Kramer, Holly; Kuffel, Gina; Thomas-White, Krystal; Wolfe, Alan J; Vellanki, Kavitha; Leehey, David J; Bansal, Vinod K; Brubaker, Linda; Flanigan, Robert; Koval, Julia; Wadhwa, Anuradha; Zilliox, Michael J

    2018-06-01

    To examine the characteristics of the midstream urine microbiome in adults with stage 3-5 non-dialysis-dependent chronic kidney disease (CKD). Patients with non-dialysis-dependent CKD (estimated glomerular filtration rate [eGFR] < 60 ml/min/1.73 m 2 ) and diuretic use were recruited from outpatient nephrology clinics. Midstream voided urine specimens were collected using the clean-catch method. The bacterial composition was determined by sequencing the hypervariable (V4) region of the bacterial 16S ribosomal RNA gene. Extraction negative controls (no urine) were included to assess the contribution of extraneous DNA from possible sources of contamination. Midstream urine microbiome diversity was assessed with the inverse Simpson, Chao and Shannon indices. The diversity measures were further examined by demographic characteristics and by comorbidities. The cohort of 41 women and 36 men with detectable bacterial DNA in their urine samples had a mean age of 71.5 years (standard deviation [SD] 7.9) years (range 60-91 years). The majority were white (68.0%) and a substantial minority were African-American (29.3%) The mean eGFR was 27.2 (SD 13.6) ml/min/1.73 m 2 . Most men (72.2%) were circumcised and 16.6% reported a remote history of prostate cancer. Many midstream voided urine specimens were dominated (> 50% reads) by the genera Corynebacterium (n = 11), Staphylococcus (n = 9), Streptococcus (n = 7), Lactobacillus (n = 7), Gardnerella (n = 7), Prevotella (n = 4), Escherichia_Shigella (n = 3), and Enterobacteriaceae (n = 2); the rest lacked a dominant genus. The samples had high levels of diversity, as measured by the inverse Simpson [7.24 (95% CI 6.76, 7.81)], Chao [558.24 (95% CI 381.70, 879.35)], and Shannon indices [2.60 (95% CI 2.51, 2.69)]. Diversity measures were generally higher in participants with urgency urinary incontinence and higher estimated glomerular filtration rate (eGFR). After controlling for demographics and diabetes status, microbiome diversity was significantly associated with estimated eGFR (P < 0.05). The midstream voided urine microbiome of older adults with stage 3-5 non-dialysis-dependent CKD is diverse. Greater microbiome diversity is associated with higher eGFR.

  3. Telomerase activity in solid transitional cell carcinoma, bladder washings, and voided urine.

    PubMed

    Lance, R S; Aldous, W K; Blaser, J; Thrasher, J B

    1998-03-04

    Telomerase activity has been detected in a wide variety of human malignancies. It appears to be one of the fundamental ingredients necessary for cellular immortality. We sought to determine the incidence of telomerase activity in solid transitional cell carcinoma (TCC) specimens, benign urothelium, bladder washings, and voided urine from patients with TCC identified cystoscopically compared with controls. Telomerase activity was measured in 26 solid bladder cancers and 13 benign urothelial specimens using the telomere repeat amplification protocol (TRAP), a polymerase chain reaction (PCR) based assay. Telomerase activity was further measured in the centrifuged cellular material obtained from the bladder washings of 26 patients with TCC and 40 with benign urologic disease found to have a normal cystoscopy. All patients with hematuria were additionally evaluated with an upper tract radiographic examination and found to be free of malignancy. Voided urine was likewise evaluated in 11 patients with TCC, 12 with benign urologic diseases, and 56 asymptomatic control subjects. Telomerase activity was detected in 25 of 26 (96%) solid specimens, 21 of 26 (81%) bladder washings, and 6 of 11 (54%) voided urine specimens from patients with histologically confirmed TCC. In the control group, 2 of 13 (15%) benign urothelial specimens and 2 of 56 (4%) voided urine specimens from the asymptomatic volunteer group demonstrated telomerase activity. Of those with benign urologic disease, 16 of 40 (40%) bladder barbotage specimens and 6 of 12 (50%) voided urine specimens demonstrated telomerase activity. Sensitivity and specificity of telomerase as a marker for TCC were 81% and 60%, respectively, in the bladder washings group and 54% and 50%, respectively, in voided urine. These data indicate that activation of telomerase is frequent in solid TCC and appears to be a sensitive marker in bladder washings of patients with TCC. We noted an unexpectedly high false positive detection rate in patients with benign urologic diseases, especially those with symptomatic benign prostatic hyperplasia. An additional study of a larger number of both bladder cancer patients and those at risk is necessary to determine if telomerase activity could play a role as a diagnostic and/or surveillance marker of TCC. Published by Elsevier Science Inc.

  4. Predictors of Urinary 3-Phenoxybenzoic Acid Levels in 50 North Carolina Adults

    PubMed Central

    Morgan, Marsha; Jones, Paul; Sobus, Jon; Boyd Barr, Dana

    2016-01-01

    Limited data are available on the non-chemical stressors that impact adult exposures to pyrethroid insecticides based on urinary biomonitoring. The urinary metabolite, 3-phenoxybenzoic acid (3-PBA), is commonly used to assess human exposure to a number of pyrethroids. In a further analysis of published study data, we quantified urinary 3-PBA levels of 50 adults over a single, 24-h sampling period and examined the associations between the biomarker measurements and selected non-chemical stressors (demographic, lifestyle, and dietary factors). A convenience sample of 50 adults was recruited in North Carolina in 2009–2011. Participants collected individual urine voids (up to 11) and filled out activity, food, and pesticide use diaries over a 24-h sampling period. Urine voids (n = 326) were analyzed for 3-PBA concentrations using high-performance liquid chromatography-tandem mass spectrometry. 3-PBA was detected in 98% of the 24-h composited urine samples. The geometric mean urinary 3-PBA level was 1.68 ng/mL in adults. Time spent outside (p = 0.0006) was a highly significant predictor of natural log-transformed (ln) urinary 3-PBA levels, while consumption of coffee (p = 0.007) and breads (p = 0.019) and ln creatinine levels (p = 0.037) were significant predictors of urinary 3-PBA levels. In conclusion, we identified specific factors that substantially increased adult exposures to pyrethroids in their everyday environments. PMID:27886113

  5. Evaluation of the performance of Human Papillomavirus testing in paired urine and clinician-collected cervical samples among women aged over 30 years in Bhutan.

    PubMed

    Tshomo, Ugyen; Franceschi, Silvia; Tshokey, Tshokey; Tobgay, Tashi; Baussano, Iacopo; Tenet, Vanessa; Snijders, Peter J F; Gheit, Tarik; Tommasino, Massimo; Vorsters, Alex; Clifford, Gary M

    2017-04-08

    Urine sampling may offer a less invasive solution than cervical sampling to test for human papillomavirus (HPV) for HPV vaccine impact monitoring. Paired samples of urine and exfoliated cervical cells were obtained for 89 women with history of high-risk (HR) HPV-positive normal cytology in Bhutan. Urine sampling protocol included self-collection of first-void urine immediately into a conservation medium and procedures to optimize DNA yield. Colposcopical abnormalities were biopsied. Two HPV assays were used: a multiplex type-specific PCR (E7-MPG) and a less analytically sensitive GP5+/6+ PCR followed by reverse line blot. HPV positivity for 21 types common to both assays was similar in urine and cells by E7-MPG (62.9% and 57.3%, respectively, p = 0.32) but lower in urine by GP5+/6+ (30.3% and 40.4%, p = 0.05). HPV6/11/16/18 positivity did not significantly differ between urine and cells by either assay. Sensitivity of urine (using cells as gold standard) to detect 21 HPV types was 80% and 58% for E7-MPG and GP5+/6+, respectively, with specificity 61% and 89%. HPV type distribution in urine and cells was similar, regardless of assay. The 5 detected CIN3+ were HR-HPV positive in cells by both assays, compared to 4 and 3 by E7-MPG and GP5+/6+, respectively, in urine samples. For the monitoring of vaccine impact, we demonstrate validity of a urine sampling protocol to obtain HPV prevalence data that are broadly comparable to that from cervical cells. However, detection of HPV in urine varies according to assay sensitivity, presumably because low level infections are frequent.

  6. The void in using urine concentration to assess population fluid intake adequacy or hydration status.

    PubMed

    Cheuvront, Samuel N; Muñoz, Colleen X; Kenefick, Robert W

    2016-09-01

    Urine concentration can be used to assess fluid intake adequacy or to diagnose dehydration. However, too often urine concentration is used inappropriately to draw dubious conclusions that could have harmful health and economic consequences. Inappropriate uses of urine concentration relate primarily to convenience sampling (timing) and problems related to convenience sampling (misapplication of thresholds), but a conceptual problem also exists with using urine concentration in isolation. The purpose of this Perspective article is to briefly explain the problematic nature of current practices and to offer a possible solution to improve practice with minimal added complication. When urine is used exclusively to assess fluid intake adequacy and hydration status in adults, we propose that only when urine concentration is high (>850 mmol/kg) and urine excretion rate is low (<850 mL/24 h) should suspicion of inadequate drinking or impending dehydration be considered. Prospective tests of the 850 × 850 thresholds will provide supporting evidence and/or help refine the best thresholds for men and women, young and old. © 2016 American Society for Nutrition.

  7. Misclassification of iodine intake level from morning spot urine samples with high iodine excretion among Inuit and non-Inuit in Greenland.

    PubMed

    Andersen, Stig; Waagepetersen, Rasmus; Laurberg, Peter

    2015-05-14

    Iodine nutrition is commonly assessed from iodine excretion in urine. A 24 h urine sample is ideal, but it is cumbersome and inconvenient. Hence, spot urine samples with creatinine to adjust for differences in void volume are widely used. Still, the importance of ethnicity and the timing of spot urine samples need to be settled. We, thus, collected 104 early morning spot urine samples and 24 h urine samples from Inuit and non-Inuit living in Greenland. Diet was assessed by a FFQ. Demographic data were collected from the national registry and by questionnaires. Iodine was measured using the Sandell-Kolthoff reaction, creatinine using the Jaffe method and para-amino benzoic acid by the HPLC method for the estimation of completeness of urine sampling and compensation of incomplete urine samples to 24 h excretion. A population-based recruitment was done from the capital city, a major town and a settlement (n 36/48/20). Participants were seventy-eight Inuit and twenty-six non-Inuit. The median 24 h iodine excretion was 138 (25th-75th percentile 89-225) μg/97 (25th-75th percentile 72-124) μg in Inuit/non-Inuit (P= 0.030), and 153 (25th-75th percentile 97-251) μg/102 (25th-75th percentile 73-138) μg (P= 0.026) when including compensated iodine excretion. Iodine excretion in 24 h urine samples increased with a rising intake of traditional Inuit foods (P= 0.005). Iodine excretion was lower in morning spot urine samples than in 24 h urine samples (P< 0.001). This difference was associated with iodine intake levels (P< 0.001), and was statistically significant when the iodine excretion level was above 150 μg/24 h. In conclusion, the iodine intake level was underestimated from morning spot urine samples if iodine excretion was above the recommended level.

  8. Evaluation of upper urinary tract tumors by FISH in Chinese patients.

    PubMed

    Shan, Zhengfei; Wu, Peng; Zheng, Shaobin; Tan, Wanlong; Zhou, Haikuan; Zuo, Yi; Qi, Huan; Zhang, Peng; Peng, Hongmei; Wang, Yanfen

    2010-12-01

    Upper urinary tract tumor (UUTT) usually presents a high grade and stage, and recurs frequently. The aim of this study was to evaluate the utility of a fluorescence in situ hybridization (FISH) assay on chromosomes 3, 7, 9, and 17 as a reliable and noninvasive method for the diagnosis of Chinese patients with UUTT. Urine specimens from 50 patients with UUTT and 25 donors without evidence of urothelial tumors were analyzed by cytology and FISH. Voided urine samples from 20 normal individuals were used to establish the cut-off values for FISH assay. The McNemar test was applied for sensitivity and specificity. The overall sensitivity of FISH was statistically significantly greater than that of cytology (84.0 vs. 40.0%, P = 0.000). The overall specificities of FISH and urine cytology were all 96.0% (P = 1.000). Polysomy in chromosomes 3, 7, and 17 were 38, 42, and 30%, respectively. Heterozygous and homozygous loss of the p16 locus was found in 36 and 32%, respectively. FISH analysis performed on cells collected from voided urine is feasible, and FISH could prove to be a reliable and less invasive ancillary test and improve the sensitivity of urine cytology in the diagnosis of UUTT. Copyright © 2010 Elsevier Inc. All rights reserved.

  9. Analysis of nocturia with 24-h urine volume, nocturnal urine volume, nocturnal bladder capacity and length of sleep duration: concept for effective treatment modality.

    PubMed

    Udo, Yukihiro; Nakao, Masahiro; Honjo, Hisashi; Ukimura, Osamu; Kawauchi, Akihiro; Kitakoji, Hiroshi; Miki, Tsuneharu

    2011-03-01

    • To determine the relationship between the number of nocturia and 24-h urine volume, nocturnal urine volume, nocturnal bladder capacity and length of sleep duration as well as to assess the significance of these factors with respect to eliminating nocturnal voidings in individual patients with nocturia. • Among 532 participants who completed a 3-day bladder diary between April 2005 and December 2006, the diaries of 450 participants without 24-h polyuria were analyzed. • Clinical variables such as the number of daytime and night-time voids, 24-h urine volume, nocturnal polyuria index, daytime and night-time maximum voided volumes (MVV), night/day MVV ratio, sleep duration and proportion of night/day urine production rates were obtained from each diary. • Participants were classified into eight groups according to values of three factors: nocturnal MVV, proportion of night/day urine production rates and length of sleep duration. • Each group was divided into three subgroups: non-nocturics (number of nocturnal voidings is zero), mild nocturics (number of nocturnal voidings is one) and severe nocturics (number of nocturnal voidings is two or more). • The data from non-nocturics with three normal factors were regarded as the normal control and compared with the variables of the other subgroups using Dunnett's method. • Variables that form the basis of classifying participants into eight groups and corresponding to abnormal factors of each group were statistically significant in all the subgroups of each group. • Furthermore, a significantly increased 24-h urine volume was found in severe nocturics of the group with three normal factors. • A significantly decreased 24-h urine volume was found in non-nocturics of groups with nocturnal polyuria, decreased bladder capacity and both long sleep duration and nocturnal polyuria. • A significantly increased nocturnal MVV and night/day MVV ratio were shown in non-nocturics and mild nocturics of the groups with nocturnal polyuria and both long sleep duration and nocturnal polyuria. • Because nocturia is a multifactorial disorder and closely related to four factors (i.e. 24-h urine volume, nocturnal urine volume, nocturnal bladder capacity and length of sleep duration), the evaluation of all these factors appears to be clinically useful for determining the main contributing factor in patients with nocturia as well as the suitable treatment modality on an individual basis. • Physicians should take all these factors into consideration in the evaluation and treatment of nocturia. © 2010 THE AUTHORS. JOURNAL COMPILATION © 2010 BJU INTERNATIONAL.

  10. Enlarged prostate

    MedlinePlus

    ... gland. Other tests may include: Urine flow rate Post-void residual urine test to see how much urine is left in your bladder after you urinate Pressure-flow studies to measure the pressure in the bladder as ...

  11. Effect of injected rotenone on the production and composition of urine from the rainbow trout (Salmo gairdneri)

    USGS Publications Warehouse

    Erickson, D.A.; Gingerich, W.H.

    1986-01-01

    Renal function was evaluated in adult rainbow trout (Salmo gairdneri) dosed i.a. with rotenone at 225 and 275 μg/kg. The chemical composition of urine samples and urine flow rates collected over a 5-h pretreatment period were compared with hourly urine samples collected over a 5-h posttreatment period. Significant increases in osmolality and in concentrations of sodium, potassium, chloride, glucose, and total protein were observed in the urine of treated fish. Urine solute concentrations reached maximum values within 1 to 3 h after treatment and decreased thereafter, indicating that the effects were reversible. Concentrations of sodium and chloride were highly correlated in 2-h posttreatment urine samples at the low (r = 0.922) and high (r = 0.981) rotenone treatments. Urine flow rates were reduced in trout at each dose of rotenone but the decrease in volume of urine voided was not dose-dependent. In a separate study, [14C]polyethylene glycol was used as a filtration marker to determine the effect of rotenone treatment (225 &mu:g/kg) on urine flow rate, glomerular filtration rate, and renal water reabsorption. We showed that posttreatment urine flow rates were reduced partly by reduced glomerular filtration and partly by increased water reabsorption. Transient increases in plasma osmolality and hematocrit also were observed 0.5 h after rotenone treatment.

  12. A clinical investigation of the mechanism of loxoprofen, a non-steroidal anti-inflammatory drug, for patients with nocturia.

    PubMed

    Araki, Tohru; Yokoyama, Teruhiko; Araki, Motoo; Furuya, Seiji

    2008-12-01

    We previously reported the effectiveness of loxoprofen sodium (loxoprofen), a non-steroidal anti-inflammatory drug, for patients with lower urinary tract symptoms (LUTS) complaining of nocturia. In this study, we explored the mechanism of loxoprofen in the treatment of nocturia. Fifty-six patients complaining of nocturia were enrolled. They took a single 60-mg tablet of loxoprofen at bedtime for 14 days. The effects of this treatment were assessed by bladder diaries. Nocturia improved (nocturia decreased >or=1 void/night) in 40 patients (71.4%). Nocturnal urine volume was reduced in 31 of 40 (77.5%) without nocturnal single-void volume increase. Nocturnal single-void volume increased in 4 of 40 (10.0%) without nocturnal urine volume reduction. Two of 40 (5.0%) demonstrated both nocturnal urine volume reduction and nocturnal single-void volume increase. Three (7.5%) were exceptions to the above. In conclusion, the main mechanism of loxoprofen is the reduction of nocturnal urine volume for the treatment of nocturia and the second mechanism is the increased bladder capacity.

  13. Modulation of male mouse genital sniff, attack, and mount behaviors by urogenital substances from estrous females.

    PubMed

    Weinhold, L L; Ingersoll, D W

    1988-09-01

    The modulation of attacks, genital sniffs, and mounts in male SJL/J mice by ovarian-dependent urogenital substances in the urine voided by estrous females was examined. Urogenital substances were applied onto the external urogenital areas of ovariectomized mice. When compared with urine voided by estrous females, which stimulated genital sniffing, mounting, and reduced aggression, bladder urine was ineffective. Genital sniffing and mounting was stimulated by estradiol-17 beta, vaginal fluids, and preputial extract. Aggression was reduced by estradiol-17 beta, urethral catheterized urine, and vaginal fluids. Preputialectomy reduced, but did not eliminate, urinary stimulation of genital sniffing and mounting. Preputial extract stimulated aggression. Urogenital substances from ovariectomized females were ineffective in reducing attacks and stimulating genital sniffs and mounts. It was concluded that the ovarian-dependent chemosignals in the urine voided by estrous females are contributed by the urethra, vagina, and preputial gland, perhaps in part through the excretion of unconjugated estrogens.

  14. Flushing of the vagina and the prepuce-a cause for contaminated urine cultures in children.

    PubMed

    Tullus, Kjell; Hooman, Nakysa; Easty, Marina

    2017-01-01

    An uncontaminated urine culture is a prerequisite for the diagnosis of a urinary tract infection. However, this may be difficult to obtain in small children. We have studied the frequency of ballooning of the prepuce in non-circumcised boys and vaginal reflux in girls during voiding as a possible cause of contaminated urine cultures. All micturating cystourethrograms (MCUG) performed in our institution over the last 5 years in children aged 0-15 years were reviewed retrospectively for ballooning of the foreskin or vaginal reflux as a potential source of bacterial contamination. The voiding pictures were routinely done with the catheter present for the first voiding cycle and then removed on the second void. A total of 526 children (77.4 % boys, 22.6 % girls) were eligible for the study. Ballooning of the foreskin was identified on the micturition pictures of 115 (38 %) boys, with the frequency significantly higher in boys aged <12 months [odds ratio (OR) 4.1; 95 % confidence interval (CI) 2.1-7.3)] and boys with vesicoureteral reflux (OR 1.6; 95 % CI 1.06-2.4). Seventeen girls (14.3 %) showed vaginal reflux. No correlation with age or vesicoureteral reflux was found in the girls. Ballooning of the prepuce or vaginal reflux was seen on a fluoroscopic MCUG in a large proportion of children during their voiding. This normal phenomenon might cause contaminated urine cultures when the urine is obtained by bag or clean catch.

  15. A pilot study of urinary microRNA as a biomarker for urothelial cancer

    PubMed Central

    Snowdon, Jaime; Boag, Sandy; Feilotter, Harriet; Izard, Jason; Siemens, D. Robert

    2013-01-01

    Objective: MicroRNAs (miRNAs) are part of a class of small ribonucleic acid (RNAs). They are important regulatory molecules, involved in several cell processes, such as developmental timing, stem cell division and apoptosis. Dysregulated miRNAs have been identified in several human malignancies, including bladder cancer tissue samples, and may confer a “tumour signature” that can be exploited for diagnostic purposes. We report on a prospective pilot study investigating the diagnostic capability of miRNAs in the urine of patients with urothelial cancer. Methods: Voided urine samples were collected from patients with urothelial carcinoma just prior to bladder tumour resection, as well as age-matched healthy control patients. Pathology demonstrated both low- and high-grade cancer. Total RNA was isolated and quantitative reverse transcriptase-polymerase chain reaction was performed on the RNA extracts using primers for 4 miRNAs shown previously to be dysregulated in solid urothelial carcinomas with RNU6B as the endogenous control. Standard urine cytology was performed on all samples in a blinded fashion. Results: Two miRNAs of interest were dysregulated in the urine from cancer patients with miR-125b showing an average 10.42-fold decrease (p < 0.01) and miR-126 showing an average 2.70-fold increase (p = 0.30) in the cancer samples compared to the normal controls. The sensitivity and specificity of the cytology on the same urine samples were 50% and 80%, respectively. Using these 2 miRNAs only, a decision-tree prediction model was generated for a validation cohort of patients yielding a specificity of 100% and a sensitivity of 80%. Discussion: This preliminary study of candidate urinary miRNA in patients with low- and high-grade urothelial cancer demonstrated a significantly improved diagnostic accuracy over cytology. These results provide rationale for further studies on discovery and validation of candidate miRNAs in voided urine and may potentially lead to the development of a non-invasive and sensitive test for bladder cancer diagnosis and prognosis. PMID:22630336

  16. Proximal tubule proteins are significantly elevated in bladder urine of patients with ureteropelvic junction obstruction and may represent novel biomarkers: A pilot study.

    PubMed

    Gerber, Claire; Harel, Miriam; Lynch, Miranda L; Herbst, Katherine W; Ferrer, Fernando A; Shapiro, Linda H

    2016-04-01

    Ureteropelvic junction obstruction (UPJO) is the major cause of hydronephrosis in children and may lead to renal injury and early renal dysfunction. However, diagnosis of the degree of obstruction and severity of renal injury relies on invasive and often inconclusive renal scans. Biomarkers from voided urine that detect early renal injury are highly desirable because of their noninvasive collection and their potential to assist in earlier and more reliable diagnosis of the severity of obstruction. Early in response to UPJO, increased intrarenal pressure directly impacts the proximal tubule brush border. We hypothesize that single-pass, apically expressed proximal tubule brush border proteins will be shed into the urine early and rapidly and will be reliable noninvasive urinary biomarkers, providing the tools for a more reliable stratification of UPJO patients. We performed a prospective cohort study at Connecticut Children's Medical Center. Bladder urine samples from 12 UPJO patients were obtained prior to surgical intervention. Control urine samples were collected from healthy pediatric patients presenting with primary nocturnal enuresis. We determined levels of NGAL, KIM-1 (previously identified biomarkers), CD10, CD13, and CD26 (potentially novel biomarkers) by ELISA in control and experimental urine samples. Urinary creatinine levels were used to normalize the urinary protein levels measured by ELISA. Each of the proximal tubule proteins outperformed the previously published biomarkers. No differences in urinary NGAL and KIM-1 levels were observed between control and obstructed patients (p = 0.932 and p = 0.799, respectively). However, levels of CD10, CD13, and CD26 were significantly higher in the voided urine of obstructed individuals when compared with controls (p = 0.002, p = 0.024, and p = 0.007, respectively) (Figure). Targeted identification of reliable, noninvasive biomarkers of renal injury is critical to aid in diagnosing patients at risk, guiding therapeutic decisions and monitoring treatment efficacy. Proximal tubule brush border proteins are reliably detected in the urine of obstructed patients and may be more effective at predicting UPJO. Copyright © 2015 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  17. Comparison of Human Papillomavirus Detections in Urine, Vulvar, and Cervical Samples from Women Attending a Colposcopy Clinic

    PubMed Central

    Gravitt, Patti E.; Dunn, S. Terence; Brown, David; Allen, Richard A.; Eby, Yolanda J.; Smith, Katie; Zuna, Rosemary E.; Zhang, Roy R.; Gold, Michael A.; Schiffman, Mark; Walker, Joan L.; Castle, Philip E.; Wentzensen, Nicolas

    2014-01-01

    While urine-based sampling for human papillomavirus (HPV) is being explored as a simple and noninvasive approach for cervical cancer screening, data comparing HPV genotyping in urine and those in cellular sampling of the cervix and vulva, and their correlation with rigorously confirmed cervical disease status, are sparse. We performed HPV genotyping on voided-urine and clinician-collected vulvar and cervical samples from 72 women undergoing colposcopy. Although urine-based HPV carcinogenic HPV detection was lower (58.3%) than cervical (73.6%) and vulvar (72.1%) detection (P = 0.05 and 0.07, respectively), the agreement of urine HPV with cervical and vulvar HPV was moderate (kappa = 0.55) and substantial (kappa = 0.62), respectively. Urine-based carcinogenic HPV detection had a clinical sensitivity of 80.8% (95% confidence interval [CI] = 60.7 to 93.5) and a specificity of 53.3% (95% CI = 37.9 to 68.3) for diagnosing cervical intraepithelial neoplasia grades 2/3 (CIN2/3) on histology; 90.0% of CIN3 was positive for urine HPV. The corresponding sensitivity and specificity values for vulvar sampling were 92% (95% CI = 74 to 99) and 40.5% (95% CI = 25.6 to 56.7), and those for cervical sampling were 96.2% (95% CI = 80.4 to 99.9) and 40% (95% CI = 25.7 to 55.7), respectively. HPV16 was the most common carcinogenic genotype detectable in 25% of urine, 33.8% of vulvar, and 31.9% of cervical samples overall, with prevalence increasing with cervical disease grade, regardless of the sampling method. Stronger cervical HPV PCR signal strengths were associated with increased frequency of urine HPV detection. In summary, the relatively lower detection rates but comparable clinical performance of urine-based HPV sampling underscore the need for larger studies to evaluate urine-based sampling for cervical cancer screening, epidemiologic studies, and postvaccination HPV disease surveillance. PMID:24197879

  18. Dose Reconstruction of Di-2-Ethylhexyl Phthalate Using a Simple Pharmacokinetic Model [Manuscript

    EPA Science Inventory

    Background In 2005, eight adults provided full volumes and times of urine voids during one normal work week. These samples were analyzed for four di-2-ethylhexyl phthalate (DEHP) metabolites. Participants also provided diary information on their diet, driving, and out¬door a...

  19. Use of a holder-vacuum tube device to save on-site hands in preparing urine samples for head-space gas-chromatography, and its application to determine the time allowance for sample sealing.

    PubMed

    Kawai, Toshio; Sumino, Kimiaki; Ohashi, Fumiko; Ikeda, Masayuki

    2011-01-01

    To facilitate urine sample preparation prior to head-space gas-chromatographic (HS-GC) analysis. Urine samples containing one of the five solvents (acetone, methanol, methyl ethyl ketone, methyl isobutyl ketone and toluene) at the levels of biological exposure limits were aspirated into a vacuum tube via holder, a device commercially available for venous blood collection (the vacuum tube method). The urine sample, 5 ml, was quantitatively transferred to a 20-ml head-space vial prior to HS-GC analysis. The loaded tubes were stored at +4 ℃ in dark for up to 3 d. The vacuum tube method facilitated on-site procedures of urine sample preparation for HS-GC with no significant loss of solvents in the sample and no need of skilled hands, whereas on-site sample preparation time was significantly reduced. Furthermore, no loss of solvents was detected during the 3-d storage, irrespective of hydrophilic (acetone) or lipophilic solvent (toluene). In a pilot application, high performance of the vacuum tube method in sealing a sample in an air-tight space succeeded to confirm that no solvent will be lost when sealing is completed within 5 min after urine voiding, and that the allowance time is as long as 30 min in case of toluene in urine. The use of the holder-vacuum tube device not only saves hands for transfer of the sample to air-tight space, but facilitates sample storage prior to HS-GC analysis.

  20. The Effects of Instrumentation on Urine Cytology and CK-20 Analysis for the Detection of Bladder Cancer.

    PubMed

    Wegelin, Olivier; Bartels, Diny W M; Tromp, Ellen; Kuypers, Karel C; van Melick, Harm H E

    2015-10-01

    To evaluate the effects of cystoscopy on urine cytology and additional cytokeratin-20 (CK-20) staining in patients presenting with gross hematuria. For 83 patients presenting with gross hematuria, spontaneous and instrumented paired urine samples were analyzed. Three patients were excluded. Spontaneous samples were collected within 1 hour before cystoscopy, and the instrumented samples were tapped through the cystoscope. Subsequently, patients underwent cystoscopic evaluation and imaging of the urinary tract. If tumor suspicious lesions were found on cystoscopy or imaging, subjects underwent transurethral resection or ureterorenoscopy. Two blinded uropathological reviewers (DB, KK) evaluated 160 urine samples. Reference standards were results of cystoscopy, imaging, or histopathology. Thirty-seven patients (46.3%) underwent transurethral resection or ureterorenoscopy procedures. In 30 patients (37.5%) tumor presence was confirmed by histopathology. The specificity of urine analysis was significantly higher for spontaneous samples than instrumented samples for both cytology alone (94% vs 72%, P = .01) and for cytology combined with CK-20 analysis (98% vs 84%, P = .02). The difference in sensitivity between spontaneous and instrumented samples was not significant for both cytology alone (40% vs 53%) and combined with CK-20 analysis (67% vs 67%). The addition of CK-20 analysis to cytology significantly increases test sensitivity in spontaneous urine cytology (67% vs 40%, P = .03). Instrumentation significantly decreases specificity of urine cytology. This may lead to unnecessary diagnostic procedures. Additional CK-20 staining in spontaneous urine cytology significantly increases sensitivity but did not improve the already high specificity. We suggest performing urine cytology and CK-20 analysis on spontaneously voided urine. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Rapid differentiation of cocci/mixed bacteria from rods in voided urine culture of women with uncomplicated urinary tract infections.

    PubMed

    Yang, Chun-Chun; Yang, Stephen Shei-Dei; Hung, Hui-Ching; Chiang, I-Ni; Peng, Chiung-Hui; Chang, Shang-Jen

    2017-09-01

    To evaluate the ability of laser flow cytometry to predict cocci/mixed growth in the pre-analytical phase of urine specimens. We retrospectively reviewed urine samples from women with uncomplicated urinary tract infections from urologic clinics for study. Urine analyses were performed with laser flow cytometry (UF1000i, Sysmex, Kobe, Japan) and then diagrams were generated (forward scatter vs. fluorescent light scatter). Each specimen (bacteria count >357 BACT/μL) was classified as either cocci bacteria or rods/mixed growth according to the diagrams. Standard urine cultures were performed, and the agreement between cultures and the UF1000i interpretations was analyzed with kappa statistics. Finally, 491 specimens met the criteria for analysis. Among the 376 specimens with single bacteria growth, there were 26 gram-positive cocci (13 Streptococci spp., 7 Staphylococci spp., 6 Enterococci spp.), 1 gram-positive rods (Corynebacterium spp.), and 349 gram-negative rods (273 Escherichia coli, 33 Klebsiella spp., 29 Proteus spp., 6 Citrobacter spp., 4 Enterobacter spp., 3 Pseudomonas spp., and 1 Providencia spp.). There were 115 specimens with two bacteria species or more that were regarded as mixed growth. Agreement of rods or cocci/mixed growth between the laser flow cytometry and urine cultures yielded a kappa value of 0.58. The positive and negative predictive rate of the UF1000i for cocci/mixed growth in voided urine culture was 81.8% and 84.7%, respectively. Through laser flow cytometry, we can predict growth of cocci/mixed growth in the pre-analytical phase of urine culture, thus avoiding unnecessary urine culture and waiting time. © 2016 Wiley Periodicals, Inc.

  2. Voided urine versus bladder washing cytology for detection of urothelial carcinoma: which is better?

    PubMed

    Keller, Anna Krarup; Jensen, Jørgen Bjerggaard

    2017-08-01

    Cytology is recommended as part of the follow-up of high-grade non-muscle-invasive bladder cancer (NMIBC). However, currently there are no solid guideline recommendations regarding the use of voided urine versus bladder washing for cytology as part of the diagnosis or follow-up of NMIBC. The aim of this study was to investigate whether the cytological outcome was equal regarding the two techniques. The authors reviewed all outpatient flexible cystoscopies carried out in their department in 2013. Patient records in the registry of pathology were examined and those with simultaneous urine and bladder washing cytology were included. Previous urothelial disease and positive histology within 3 months after the cystoscopy were registered. A total of 1458 patients had both voided urine and bladder washing cytology and were included in the study, of whom 643 (44%) had a history of urothelial disease. An equal outcome of urine and bladder washing cytology was found in 1447 patients (99.2%). For the remaining 11 patients, only four patients underwent further examinations based on cytology findings in addition to what had already been planned after cystoscopy. Of the included patients, 100 (6.9%) had a positive histological outcome within 3 months. In most patients, no relevant difference between voided urine and bladder washing cytology was observed. Therefore, if cytology is indicated, it is recommended to use the test that is most readily available locally. The additional gain in using both urine and bladder wash is minimal, and can therefore be discarded.

  3. Urinalysis in children and adolescents.

    PubMed

    Utsch, Boris; Klaus, Günter

    2014-09-12

    Urinalysis is the most commonly performed biochemical test in infancy and early childhood. The urine sample should be correctly obtained, age-specific aspects should be considered, and age-dependent reference values should be used. This review is based on a selective literature search in electronic databases, textbooks, and guidelines from Germany and abroad on the acquisition of urine samples and the performance of urinalysis in infancy and early childhood. The timing and mode of acquisition of the urine sample affect the assessment of hematuria, proteinuria, leukocyturia, nitrituria, and the uropathogenic bacterial colony count in the urine culture. Dipstick tests can be used for targeted screening for these features. The test results should be interpreted together with the findings of urine microscopy, the medical history, and the physical examination. Proteinuria should be quantified and differentiated; both of these things can be done either from collected urine or (especially in infants and young children) from a spontaneously voided urine sample, by determination of the protein/creatinine quotient. Orthostatic proteinuria in an adolescent requires no further evaluation or treatment. Hematuria should be characterized as either glomerular or non-glomerular erythrocyturia. Asymptomatic, isolated microhematuria in childhood is not uncommon and often transient; in the absence of a family history, it usually does not require an extensive work-up. Proteinuria combined with hematuria should arouse the suspicion of glomerulonephritis. Urinalysis in infancy and early childhood is a simple and informative diagnostic test as long as the urine sample has been obtained properly and the results are interpreted appropriately for this age group.

  4. The consequence of delayed fixation on subsequent preservation of urine cells.

    PubMed

    Ahmed, Hussain G; Tom, Murtada Am

    2011-01-01

    Degenerative changes caused by delays in urine preservation contribute to false-negative and false-positive interpretation of urothelial disease in cytology. The aim of this study is to assess whether the delay of fixation of urine samples makes any significant difference to urine cytology and morphology, and the limit of acceptability of delay for routine use in the hospital laboratory. Three cell collection fluids were evaluated by analyzing the preservation and degeneration of cells in urine samples. In this study, 50 voided urine specimens were taken at random from females complaining of vaginal discharge. Each specimen was divided into three sterile containers. The first was immediately centrifugated and the deposit was smeared onto a cleaned micro slide and immediately fixed into 95% ethyl alcohol for 15 minutes. The remaining two were prepared in the same manner, however, the second after two hours of collection and the third after four hours of collection. The degree of degeneration and thus the preservation were assessed by a table of chosen criteria, then ranked and analyzed using Friedman's nonparametric test, at p=0.05. The results showed a significant difference between the preservation and the delay in urine fixation, p<0.0001. Any delay in fixation of urine specimen for cytology affects the preservation of cells, which may result in miss diagnosis. It is recommended that urine samples for cytology should be fixed immediately after collection.

  5. Urine collection in the emergency department: what really happens in there?

    PubMed

    Frazee, Bradley W; Frausto, Kenneth; Cisse, Bitou; White, Douglas E A; Alter, Harrison

    2012-11-01

    In women with suspected urinary tract infection (UTI), a non-contaminated voided specimen is considered important for valid urinalysis and culture results. We assess whether midstream parted-labia catch (MSPC) instructions were provided by nurses, understood, and performed correctly, according to the patient. We conducted a cross-sectional survey of English- and Spanish-speaking female patients submitting voided urine samples for urinalysis for suspected UTI. The survey was conducted in a public teaching hospital emergency department (ED) from June to December 2010, beginning 2 months after development and dissemination of a nursing MSPC instructions protocol. Research assistants administered the survey within 2 hours of urine collection. Nurses were unaware of the study purpose. Of 129 patients approached, 74 (57%) consented and were included in the analysis. Median age was 35; 44% were Latino. Regarding instructions from nurses, patients reported the following: 45 (61%; 95% CI 50-72%) received any instructions; of whom 37 (82%; 95% CI 71-93%) understood them completely. Sixteen (36%; 95% CI 22-51%) were instructed to collect midstream; and 7 (16%; 95% CI 6-29%) to part the labia. Regardless of receiving or understanding instructions, 33 (45%; 95% CI 33-57%) reported actually collecting midstream, and 11 (15%, 95% CI 8-25%) parting the labia. In this ED, instructions for MSPC urine collection frequently were not given, despite a nursing protocol, and patients rarely performed the essential steps. An evidence-based approach to urine testing in the ED that considers urine collection technique, is needed.

  6. Unnoticed Post-Void Residual Urine Volume in People with Moderate to Severe Intellectual Disabilities: Prevalence and Risk Factors

    ERIC Educational Resources Information Center

    de Waal, K. H.; Tinselboer, B. M.; Evenhuis, H. M.; Penning, C.

    2009-01-01

    Background: Increased post-void residual urine volume (PVR) is often seen in geriatric populations. People with intellectual disabilities (ID) have risk factors in common with these populations. Aims: To investigate in adults with ID: (1) Feasibility of portable ultrasound bladder scanning; (2) Prevalence of PVR; and (3) Relations with proposed…

  7. The resident microflora of voided midstream urine of healthy controls: standard versus expanded urine culture protocols.

    PubMed

    Coorevits, L; Heytens, S; Boelens, J; Claeys, G

    2017-04-01

    The workup and interpretation of urine cultures is not always clear-cut, especially for midstream samples contaminated with commensals. Standard urine culture (SUC) protocols are designed in favor of growth of uropathogens at the expense of commensals. In selected clinical situations, however, it is essential to trace fastidious or new uropathogens by expanding the urine culture conditions (EUC). The aim of our study was to map the microflora in midstream urine specimens from healthy controls by means of EUC, in view of the interpretation of bacterial culture results in symptomatic patients. Midstream urine specimens from 101 healthy controls (86 females and 15 males) were examined using both SUC and EUC. Whilst 73 % of samples examined by SUC showed no growth at 10 3  colony-forming units (CFU)/mL, 91 % of samples examined by EUC grew bacterial species in large numbers (≥10 4  CFU/mL). Asymptomatic bacteriuria, as defined by the European guidelines for urinalysis, was detected in six samples with both protocols. EUC revealed 98 different species, mostly Lactobacillus, Staphylococcus, Streptococcus, and Corynebacterium. None of the samples grew Staphylococcus saprophyticus, Corynebacterium urealyticum, or Aerococcus urinae. Samples from females contained higher bacterial loads and showed higher bacterial diversity compared to males. Midstream urine of healthy controls contains large communities of living bacteria that comprise a resident microflora, only revealed by EUC. Hence, the use of EUC instead of SUC in a routine setting would result in more sensitive but less specific results, requiring critical interpretation. In our view, EUC should be reserved for limited indications.

  8. Variability of Organophosphorous Pesticide Metabolite Levels in Spot and 24-hr Urine Samples Collected from Young Children during 1 Week

    PubMed Central

    Kogut, Katherine; Eisen, Ellen A.; Jewell, Nicholas P.; Quirós-Alcalá, Lesliam; Castorina, Rosemary; Chevrier, Jonathan; Holland, Nina T.; Barr, Dana Boyd; Kavanagh-Baird, Geri; Eskenazi, Brenda

    2012-01-01

    Background: Dialkyl phosphate (DAP) metabolites in spot urine samples are frequently used to characterize children’s exposures to organophosphorous (OP) pesticides. However, variable exposure and short biological half-lives of OP pesticides could result in highly variable measurements, leading to exposure misclassification. Objective: We examined within- and between-child variability in DAP metabolites in urine samples collected during 1 week. Methods: We collected spot urine samples over 7 consecutive days from 25 children (3–6 years of age). On two of the days, we collected 24-hr voids. We assessed the reproducibility of urinary DAP metabolite concentrations and evaluated the sensitivity and specificity of spot urine samples as predictors of high (top 20%) or elevated (top 40%) weekly average DAP metabolite concentrations. Results: Within-child variance exceeded between-child variance by a factor of two to eight, depending on metabolite grouping. Although total DAP concentrations in single spot urine samples were moderately to strongly associated with concentrations in same-day 24-hr samples (r ≈ 0.6–0.8, p < 0.01), concentrations in spot samples collected > 1 day apart and in 24-hr samples collected 3 days apart were weakly correlated (r ≈ –0.21 to 0.38). Single spot samples predicted high (top 20%) and elevated (top 40%) full-week average total DAP excretion with only moderate sensitivity (≈ 0.52 and ≈ 0.67, respectively) but relatively high specificity (≈ 0.88 and ≈ 0.78, respectively). Conclusions: The high variability we observed in children’s DAP metabolite concentrations suggests that single-day urine samples provide only a brief snapshot of exposure. Sensitivity analyses suggest that classification of cumulative OP exposure based on spot samples is prone to type 2 classification errors. PMID:23052012

  9. Urine colorimetry to detect Low rifampin exposure during tuberculosis therapy: a proof-of-concept study.

    PubMed

    Zentner, Isaac; Schlecht, Hans P; Khensouvann, Lorna; Tamuhla, Neo; Kutzler, Michele; Ivaturi, Vijay; Pasipanodya, Jotam G; Gumbo, Tawanda; Peloquin, Charles A; Bisson, Gregory P; Vinnard, Christopher

    2016-06-01

    The cost and complexity of current approaches to therapeutic drug monitoring during tuberculosis (TB) therapy limits widespread use in areas of greatest need. We sought to determine whether urine colorimetry could have a novel application as a form of therapeutic drug monitoring during anti-TB therapy. Among healthy volunteers, we evaluated 3 dose sizes of rifampin (150 mg, 300 mg, and 600 mg), performed intensive pharmacokinetic sampling, and collected a timed urine void at 4 h post-dosing. The absorbance peak at 475 nm was measured after rifamycin extraction. The optimal cutoff was evaluated in a study of 39 HIV/TB patients undergoing TB treatment in Botswana. In the derivation study, a urine colorimetric assay value of 4.0 × 10(-2) Abs, using a timed void 4 h after dosing, demonstrated a sensitivity of 92 % and specificity of 60 % to detect a peak rifampin concentration (Cmax) under 8 mg/L, with an area under the ROC curve of 0.92. In the validation study, this cutoff was specific (100 %) but insensitive (28 %). We observed similar test characteristics for a target Cmax target of 6.6 mg/L, and a target area under the drug concentration-versus-time curve (AUC0-8) target of 24.1 mg•hour/L. The urine colorimetric assay was specific but insensitive to detect low rifampin serum concentrations among HIV/TB patients. In future work we will attempt to optimize sampling times and assay performance, with the goal of delivering a method that can translate into a point-of-care assessment of rifampin exposure during anti-TB therapy.

  10. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration

    PubMed Central

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    Background The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. Methods During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Results Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. Conclusions The UPCR in samples with low or high specific gravity is more likely to overestimate or underestimate actual daily urine protein amount, respectively, especially in a dilute urine sample with its creatinine below 38.8 mg/dL or a concentrated sample with its creatinine above 61.5 mg/dL. In particular, UPCR results should be interpreted with caution in cases that involve dilute urine samples because its overestimation may lead to an erroneous diagnosis of proteinuric renal disease or an incorrect staging of chronic kidney disease. PMID:26353117

  11. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration.

    PubMed

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. The UPCR in samples with low or high specific gravity is more likely to overestimate or underestimate actual daily urine protein amount, respectively, especially in a dilute urine sample with its creatinine below 38.8 mg/dL or a concentrated sample with its creatinine above 61.5 mg/dL. In particular, UPCR results should be interpreted with caution in cases that involve dilute urine samples because its overestimation may lead to an erroneous diagnosis of proteinuric renal disease or an incorrect staging of chronic kidney disease.

  12. Does increased urination frequency protect against bladder cancer?

    PubMed

    Silverman, Debra T; Alguacil, Juan; Rothman, Nathaniel; Real, Francisco X; Garcia-Closas, Montserrat; Cantor, Kenneth P; Malats, Nuria; Tardon, Adonina; Serra, Consol; Garcia-Closas, Reina; Carrato, Alfredo; Lloreta, Josep; Samanic, Claudine; Dosemeci, Mustafa; Kogevinas, Manolis

    2008-10-01

    Experimental studies suggest that increased urination frequency may reduce bladder cancer risk if carcinogens are present in the urine. Only 2 small studies of the effect of increased urination frequency on bladder cancer risk in humans have been conducted with conflicting results. Our purpose was to evaluate the effect of urination frequency on risk of bladder cancer in a large, multicenter case-control study. We analyzed data based on interviews conducted with 884 patients with newly diagnosed, bladder cancer and 996 controls from 1998 to 2001 in Spain. We observed a consistent, inverse trend in risk with increasing nighttime voiding frequency in both men (p = 0.0003) and women (p = 0.07); voiding at least 2 times per night was associated with a significant, 40-50% risk reduction. The protective effect of nocturia was apparent among study participants with low, moderate and high water consumption. The risk associated with cigarette smoking was reduced by nocturia. Compared with nonsmokers who did not urinate at night, current smokers who did not urinate at night had an OR of 7.0 (95% CI = 4.7-10.2), whereas those who voided at least twice per night had an OR of 3.3 (95% CI = 1.9-5.8) (p value for trend = 0.0005). Our findings suggest a strong protective effect of nocturia on bladder cancer risk, providing evidence in humans that bladder cancer risk is related to the contact time of the urothelium with carcinogens in urine. Increased urination frequency, coupled with possible dilution of the urine from increased water intake, may diminish the effect of urinary carcinogens on bladder cancer risk.

  13. Urge incontinence

    MedlinePlus

    ... much urine you lost. Pelvic or abdominal ultrasound . Post void residual to measure the amount of urine left in your bladder after you urinate. Urinalysis to check for infection . Urinary stress test (you stand with a full bladder and cough). ...

  14. The Clock mutant mouse is a novel experimental model for nocturia and nocturnal polyuria.

    PubMed

    Ihara, Tatsuya; Mitsui, Takahiko; Nakamura, Yuki; Kira, Satoru; Miyamoto, Tatsuya; Nakagomi, Hiroshi; Sawada, Norifumi; Hirayama, Yuri; Shibata, Keisuke; Shigetomi, Eiji; Shinozaki, Yoichi; Yoshiyama, Mitsuharu; Andersson, Karl-Erik; Nakao, Atsuhito; Takeda, Masayuki; Koizumi, Schuichi

    2017-04-01

    The pathophysiologies of nocturia (NOC) and nocturnal polyuria (NP) are multifactorial and their etiologies remain unclear in a large number of patients. Clock genes exist in most cells and organs, and the products of Clock regulate circadian rhythms as representative clock genes. Clock genes regulate lower urinary tract function, and a newly suggested concept is that abnormalities in clock genes cause lower urinary tract symptoms. In the present study, we investigated the voiding behavior of Clock mutant (Clock Δ19/Δ19 ) mice in order to determine the effects of clock genes on NOC/NP. Male C57BL/6 mice aged 8-12 weeks (WT) and male C57BL/6 Clock Δ19/Δ19 mice aged 8 weeks were used. They were bred under 12 hr light/dark conditions for 2 weeks and voiding behavior was investigated by measuring water intake volume, urine volume, urine volume/void, and voiding frequency in metabolic cages in the dark and light periods. No significant differences were observed in behavior patterns between Clock Δ19/Δ19 and WT mice. Clock Δ19/Δ19 mice showed greater voiding frequencies and urine volumes during the sleep phase than WT mice. The diurnal change in urine volume/void between the dark and light periods in WT mice was absent in Clock Δ19/Δ19 mice. Additionally, functional bladder capacity was significantly lower in Clock Δ19/Δ19 mice than in WT mice. We demonstrated that Clock Δ19/Δ19 mice showed the phenotype of NOC/NP. The Clock Δ19/Δ19 mouse may be used as an animal model of NOC and NP. Neurourol. Urodynam. 36:1034-1038, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  15. Mechanical characterization of benign and malignant urothelial cells from voided urine

    NASA Astrophysics Data System (ADS)

    Shojaei-Baghini, Ehsan; Zheng, Yi; Jewett, Michael A. S.; Geddie, William B.; Sun, Yu

    2013-03-01

    This study investigates whether mechanical differences exist between benign and malignant urothelial cells in voided urine. The Young's modulus of individual cells was measured using the micropipette aspiration technique. Malignant urothelial cells showed significantly lower Young's modulus values compared to benign urothelial cells. The results indicate that Young's modulus as a biomechanical marker could possibly provide additional information to conventional urinary cytology. We hope that these preliminary results could evoke attention to mechanical characterization of urine cells and spark interest in the development of biomechanical approaches to enhance non-invasive urothelial carcinoma detection.

  16. Can a Simplified 12-Hour Nighttime Urine Collection Predict Urinary Stone Risk?

    PubMed

    Hinck, Bryan D; Ganesan, Vishnuvardhan; Tarplin, Sarah; Asplin, John; Granja, Ignacio; Calle, Juan; Sivalingam, Sri; Monga, Manoj

    2017-10-01

    To determine if there is correlation between nighttime 12-hour and traditional 24-hour urine collection in regard to chemistry values and the supersaturations of calcium oxalate, calcium phosphate, and uric acid for the metabolic evaluation of nephrolithiasis. Ninety-five patients were prospectively enrolled from 2013 to 2015. Patients >18 years of age who presented to a tertiary stone clinic and who would normally be counseled for 24-hour urine collection were eligible for the study. Participants completed 24-hour urine collections twice, with each divided into 2 separate 12-hour collections. Day-time collection began after the first morning void and continued for 12 hours. The night collection proceeded for the next 12 hours through the first morning void. Forty-nine 24-hour samples from 35 patients met inclusion criteria and were included in the analysis. Overall, there was strong correlation between the night 12-hour and the 24-hour urine collections with R 2 ranging from 0.76 for pH to 0.96 for Citrate. In our analysis of variability, the nighttime 12-hour collection differed from the 24-hour collection by 30% in 1-9 patients (2.0%-18.4%) based on individual chemistry value. Diagnosis of underlying metabolic abnormalities was concordant in 92% of patients. A 12-hour nighttime collection has strong correlation with 24-hour urine collection. As such, simplifying the metabolic evaluation to a 12-hour overnight collection may be feasible-improving compliance and decreasing patient burden. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Bacterial loads of Ureaplasma parvum contribute to the development of inflammatory responses in the male urethra.

    PubMed

    Deguchi, Takashi; Shimada, Yasushi; Horie, Kengo; Mizutani, Kohsuke; Seike, Kensaku; Tsuchiya, Tomohiro; Yokoi, Shigeaki; Yasuda, Mitsuru; Ito, Shin

    2015-12-01

    Ureaplasma parvum, which has been recognised as a coloniser in the male urethra, is detected in some men with non-gonococcal urethritis. In this study, we quantified the 16 S rRNA genes of U. parvum by a real-time polymerase chain reaction-based assay in first-voided urine from 15 symptomatic and 38 asymptomatic men who were positive only for U. parvum. We also determined the leukocyte counts by automated quantitative urine particle analysis in their first-voided urine. Positive correlations were observed between copies of the 16 S rRNA genes of U. parvum/ml and the leukocyte counts/µl in first-voided urine (p = 0.0019). The loads of ≥10(4) copies of the 16 S rRNA gene/ml, corresponding to ≥5 × 10(3) cells of U. parvum/ml, were significantly associated with the presence of ≥12.5 leukocytes/µl in first-voided urine that might document the presence of inflammatory responses in the urethra. However, a large portion of the subjects (83.0%) had bacterial loads of <5 × 10(3) cells of U. parvum/ml, and 79.5% of them showed <12.5 leukocytes/µl. The ambiguity of the pathogenic role of U. parvum in non-gonococcal urethritis could, in part, be due to its low bacterial loads, which might not give rise to inflammatory responses in the male urethra. © The Author(s) 2015.

  18. UroMark-a urinary biomarker assay for the detection of bladder cancer.

    PubMed

    Feber, Andrew; Dhami, Pawan; Dong, Liqin; de Winter, Patricia; Tan, Wei Shen; Martínez-Fernández, Mónica; Paul, Dirk S; Hynes-Allen, Antony; Rezaee, Sheida; Gurung, Pratik; Rodney, Simon; Mehmood, Ahmed; Villacampa, Felipe; de la Rosa, Federico; Jameson, Charles; Cheng, Kar Keung; Zeegers, Maurice P; Bryan, Richard T; James, Nicholas D; Paramio, Jesus M; Freeman, Alex; Beck, Stephan; Kelly, John D

    2017-01-01

    Bladder cancer (BC) is one of the most common cancers in the western world and ranks as the most expensive to manage, due to the need for cystoscopic examination. BC shows frequent changes in DNA methylation, and several studies have shown the potential utility of urinary biomarkers by detecting epigenetic alterations in voided urine. The aim of this study is to develop a targeted bisulfite next-generation sequencing assay to diagnose BC from urine with high sensitivity and specificity. We defined a 150 CpG loci biomarker panel from a cohort of 86 muscle-invasive bladder cancers and 30 normal urothelium. Based on this panel, we developed the UroMark assay, a next-generation bisulphite sequencing assay and analysis pipeline for the detection of bladder cancer from urinary sediment DNA. The 150 loci UroMark assay was validated in an independent cohort ( n  = 274, non-cancer ( n  = 167) and bladder cancer ( n  = 107)) voided urine samples with an AUC of 97%. The UroMark classifier sensitivity of 98%, specificity of 97% and NPV of 97% for the detection of primary BC was compared to non-BC urine. Epigenetic urinary biomarkers for detection of BC have the potential to revolutionise the management of this disease. In this proof of concept study, we show the development and utility of a novel high-throughput, next-generation sequencing-based biomarker for the detection of BC-specific epigenetic alterations in urine.

  19. Voided Midstream Urine Culture and Acute Cystitis in Premenopausal Women

    PubMed Central

    Hooton, Thomas M; Roberts, Pacita L.; Cox, Marsha E.; Stapleton, Ann E.

    2014-01-01

    BACKGROUND The cause of acute uncomplicated cystitis is determined on the basis of cultures of voided midstream urine, but few data guide the interpretation of such results, especially when gram-positive bacteria grow. METHODS Women from 18 to 49 years of age with symptoms of cystitis provided specimens of midstream urine, after which we collected urine by means of a urethral catheter for culture (catheter urine). We compared microbial species and colony counts in the paired specimens. The primary outcome was a comparison of positive predictive values and negative predictive values of organisms grown in midstream urine, with the presence or absence of the organism in catheter urine used as the reference. RESULTS The analysis of 236 episodes of cystitis in 226 women yielded 202 paired specimens of midstream urine and catheter urine that could be evaluated. Cultures were positive for uropathogens in 142 catheter specimens (70%), 4 of which had more than one uropathogen, and in 157 midstream specimens (78%). The presence of Escherichia coli in midstream urine was highly predictive of bladder bacteriuria even at very low counts, with a positive predictive value of 102 colony-forming units (CFU) per milliliter of 93% (Spearman’s r = 0.944). In contrast, in midstream urine, enterococci (in 10% of cultures) and group B streptococci (in 12% of cultures) were not predictive of bladder bacteriuria at any colony count (Spearman’s r = 0.322 for enterococci and 0.272 for group B streptococci). Among 41 episodes in which enterococcus, group B streptococci, or both were found in midstream urine, E. coli grew from catheter urine cultures in 61%. CONCLUSIONS Cultures of voided midstream urine in healthy premenopausal women with acute uncomplicated cystitis accurately showed evidence of bladder E. coli but not of enterococci or group B streptococci, which are often isolated with E. coli but appear to rarely cause cystitis by themselves. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases.) PMID:24224622

  20. Is Urinary Cadmium a Biomarker of Long-term Exposure in Humans? A Review

    PubMed Central

    Kruse, Danielle; Harrington, James; Levine, Keith; Meliker, Jaymie R.

    2017-01-01

    Cadmium is a naturally-occurring element, and humans are exposed from cigarettes, food, and industrial sources. Following exposure, cadmium accumulates in the kidney and is slowly released into the urine, usually proportionally to the levels found in the kidneys. Cadmium levels in a single spot urine sample have been considered indicative of long-term exposure to cadmium; however, such a potentially exceptional biomarker requires careful scrutiny. In this review, we report good to excellent temporal stability of urinary cadmium (intraclass correlation coefficient 0.66–0.81) regardless of spot urine or first morning void sampling. Factors such as changes in smoking habits and diseases characterized by increased excretion of proteins may produce short-term changes in urinary cadmium levels. We recommend that epidemiologists use this powerful biomarker in prospective studies stratified by smoking status, along with thoughtful consideration of additional factors that can influence renal physiology and cadmium excretion. PMID:27696280

  1. A single measurement of biochemical markers of bone turnover has limited utility in the individual person.

    PubMed

    Beck-Jensen, J E; Kollerup, G; Sørensen, H A; Pors Nielsen, S; Sørensen, O H

    1997-07-01

    Biochemical markers of bone turnover are used to estimate the rate of bone loss in the individual osteoporotic patient. During recent years it has become increasingly clear that the biological variability of biochemical bone markers has to be taken into consideration in the evaluation of their usefulness in the clinical setting. Eleven premenopausal, 8 perimenopausal and 11 postmenopausal healthy women were included. We assessed the analytical and the biological components of variation for a number of resorptive and formative bone markers: u-hydroxyproline, u-pyridinoline, and u-deoxypyridinoline together with u-calcium and u-creatinine, s-total alkaline phosphatases and s-osteocalcin. Blood and urine samples were collected five times with 7-day intervals. Urinary parameters were expressed as outputs and corrected for creatinine in fasting night urines and second void fasting morning urines. The absolute values differed with a tendency towards increasing values in the postmenopausal women, but the biological variations in relation to menopausal status were not different. The biological variability was much higher for the urinary resorptive markers than for the formative markers in the blood. The critical difference expressing the difference needed between two serial results from the same person to be significant at a 5% level was 15% for s-alkaline phosphatases, 18% for s-osteocalcin, and lowest in the second void fasting morning urines with values of 28% and 34% for u-pyridinoline/creatinine and u-deoxypyridinoline/creatinine, and 50% and 112% for u-hydroxyproline/creatinine and u-calcium/creatinine, respectively. The index of individuality, denoting the individual variation divided by the variation between subjects, was in the range from 0.19 for s-alkaline phosphatases to 1.23 for u-hydroxyproline/minute in second void fasting morning urine making the use of conventional reference intervals difficult. Low indices, however, indicate high test performance and offer the possibility of stratification of persons within a range. The number of samples required to determine the true individual mean value +/- 5% for the single person, ranged from 5 for s-total alkaline phosphatases, 6 for s-osteocalcin, 23 for u-deoxypyridinoline/creatinine in the fasting morning urine to over two hundred for u-calcium analytes. It is concluded that, due to high biological variation, a single measurement of biochemical markers of bone turnover is of limited utility in the individual person. We recommend that routine clinical use of biochemical markers should be restricted until further evidence justifies it.

  2. Long-term therapeutic efficacy of photo-selective vaporization of prostate

    NASA Astrophysics Data System (ADS)

    Arum, Carl-Jørgen; Muller, Camilla; Romundstad, Pal; Stokkan, Inger; Mjønes, Jan

    2010-02-01

    OBJECTIVES: We evaluated the long term therapeutic efficacy of 80 watt photo-selective vaporization of the prostate (PVP) in patients suffering from lower urinary tract symptoms (LUTS) secondary to prostatic obstruction. MATERIAL & METHODS: 150 unselected patients at the average age 73 (range 51-92) and a mean American Society of Anesthesiologists score of 2.4 (median 2.0), of whom 33% were medicated with acetylsalicylic acid and 5% were anticoagulated with warfarin. Inclusion/exclusion criteria were the same as for TUR-P at our institution. First patient was operated March 2004 and yearly follow-up of all patients has been attempted for 5 years. Follow-up variables have included yearly creatinine, PSA, IPSS, ØOL, post-void residual urin and maximum/average urine flow rate. RESULTS: At 12 and 24 months postoperatively, the following parameters were significantly (p<0.001) improved: trans-rectal ultrasound, international prostate symptom score, quality of life score, post-void residual urine volume, flow max/average, opening pressure, pressure @ flow-max, and micturition resistance. At 48 and 60 months creatinine, PSA, IPSS, ØOL, post-void residual urin and maximum/average urine flow rates were still significantly (p<0.001) improved compared to pre-operative values. CONCLUSION: Up to 5 year follow-up reveals that 80 watt PVP provides significant and stable symptom relief as well as objective improvement in residual urine and flowmetric outcomes.

  3. Evaluation of a new amplified enzyme immunoassay (EIA) for the detection of Chlamydia trachomatis in male urine, female endocervical swab, and patient obtained vaginal swab specimens

    PubMed Central

    Tanaka, M.; Nakayama, H.; Sagiyama, K.; Haraoka, M.; Yoshida, H.; Hagiwara, T.; Akazawa, K.; Naito, S.

    2000-01-01

    Aims—To compare the performance of a new generation dual amplified enzyme immunoassay (EIA) with a molecular method for the diagnosis of Chlamydia trachomatis, using a range of urogenital samples, and to assess the reliability of testing self collected vaginal specimens compared with clinician collected vaginal specimens. Methods—Two population groups were tested. For the first population group, first void urine samples were collected from 193 male patients with urethritis, and endocervical swabs were collected from 187 high risk commercial sex workers. All urine and endocervical specimens were tested by a conventional assay (IDEIA chlamydia), a new generation amplified immunoassay (IDEIA PCE chlamydia), and the Amplicor polymerase chain reaction (PCR). Discrepant results obtained among the three sample types were confirmed using a nested PCR test with a different plasmid target region. For the second population group, four swab specimens, including one patient obtained vaginal swab, two clinician obtained endocervical swabs, and one clinician obtained vaginal swab, were collected from 91 high risk sex workers. Self collected and clinician collected vaginal swabs were tested by IDEIA PCE chlamydia. Clinician obtained endocervical swabs were assayed by IDEIA PCE chlamydia and Amplicor PCR. Results—The performance of the IDEIA PCE chlamydia test was comparable to that of the Amplicor PCR test when male urine and female endocervical swab specimens were analysed. The relative sensitivities of IDEIA, IDEIA PCE, and Amplicor PCR on male first void urine specimens were 79.3%, 91.4%, and 100%, respectively. The relative sensitivities of the three tests on female endocervical specimens were 85.0%, 95.0%, and 100%, respectively. The positivity rates for patient collected vaginal specimens and clinician collected vaginal specimens by IDEIA PCE were 25.2% and 23.1%, respectively, whereas those for clinician collected endocervical swabs by PCR and IDEIA PCE were both 27.5%. Conclusions—IDEIA PCE chlamydia is a lower cost but sensitive alternative test to PCR for testing male urine samples and female endocervical swabs. In addition, self collected or clinician collected vaginal specimens tested by IDEIA PCE chlamydia are a reliable alternative to analysing endocervical specimens. Key Words: Chlamydia trachomatis • enzyme immunoassay • clinical specimens PMID:10889816

  4. Matrix Metalloproteinases as a Therapeutic Target to Improve Neurologic Recovery after Spinal Cord Injury

    DTIC Science & Technology

    2012-10-01

    pressure (maximal vesical pressure in an animal without voluntary voiding, prior to urine overflow), voiding duration, and voiding interval (the frequency...until euthanasia . Neurological status was evaluated at 1 and 3 days post injury and weekly thereafter for 3 weeks. At 4 weeks post-injury, awake

  5. Clinical Guideline for Female Lower Urinary Tract Symptoms.

    PubMed

    Takahashi, Satoru; Takei, Mineo; Nishizawa, Osamu; Yamaguchi, Osamu; Kato, Kumiko; Gotoh, Momokazu; Yoshimura, Yasukuni; Takeyama, Masami; Ozawa, Hideo; Shimada, Makoto; Yamanishi, Tomonori; Yoshida, Masaki; Tomoe, Hikaru; Yokoyama, Osamu; Koyama, Masayasu

    2016-01-01

    The "Japanese Clinical Guideline for Female Lower Urinary Tract Symptoms," published in Japan in November 2013, contains two algorithms (a primary and a specialized treatment algorithm) that are novel worldwide as they cover female lower urinary tract symptoms other than urinary incontinence. For primary treatment, necessary types of evaluation include querying the patient regarding symptoms and medical history, examining physical findings, and performing urinalysis. The types of evaluations that should be performed for select cases include evaluation with symptom/quality of life (QOL) questionnaires, urination records, residual urine measurement, urine cytology, urine culture, serum creatinine measurement, and ultrasonography. If the main symptoms are voiding/post-voiding, specialized treatment should be considered because multiple conditions may be involved. When storage difficulties are the main symptoms, the patient should be assessed using the primary algorithm. When conditions such as overactive bladder or stress incontinence are diagnosed and treatment is administered, but sufficient improvement is not achieved, the specialized algorithm should be considered. In case of specialized treatment, physiological re-evaluation, urinary tract/pelvic imaging evaluation, and urodynamic testing are conducted for conditions such as refractory overactive bladder and stress incontinence. There are two causes of voiding/post-voiding symptoms: lower urinary tract obstruction and detrusor underactivity. Lower urinary tract obstruction caused by pelvic organ prolapse may be improved by surgery. © 2015 Wiley Publishing Asia Pty Ltd.

  6. Urine Flow Dynamics Through Prostatic Urethra With Tubular Organ Modeling Using Endoscopic Imagery

    PubMed Central

    Kambara, Yoichi; Yamanishi, Tomonori; Naya, Yukio; Igarashi, Tatsuo

    2014-01-01

    Voiding dysfunction is common in the aged male population. However, the obstruction mechanism in the lower urinary tract and critical points for obstruction remains uncertain. The aim of this paper was to develop a system to investigate the relationship between voiding dysfunction and alteration of the shape of the prostatic urethra by processing endoscopic video images of the urethra and analyzing the fluid dynamics of the urine stream. A panoramic image of the prostatic urethra was generated from cystourethroscopic video images. A virtual 3-D model of the urethra was constructed using the luminance values in the image. Fluid dynamics using the constructed model was then calculated assuming a static urethra and maximum urine flow rate. Cystourethroscopic videos from 11 patients with benign prostatic hyperplasia were recorded around administration of an alpha-1 adrenoceptor antagonist. The calculated pressure loss through the prostatic urethra in each model corresponded to the prostatic volume, and the improvements of the pressure loss after treatment correlated to the conventional clinical indices. As shown by the proposed method, the shape of the prostatic urethra affects the transporting urine fluid energy, and this paper implies a possible method for detecting critical lesions responsible for voiding dysfunction. The proposed method provides critical information about deformation of the prostatic urethra on voiding function. Detailed differences in the various types of relaxants for the lower urinary tract could be estimated. PMID:27170869

  7. Patterns of human papillomavirus types in multiple infections: an analysis in women and men of the high throughput human papillomavirus monitoring study.

    PubMed

    Vaccarella, Salvatore; Söderlund-Strand, Anna; Franceschi, Silvia; Plummer, Martyn; Dillner, Joakim

    2013-01-01

    To evaluate the pattern of co-infection of human papillomavirus (HPV) types in both sexes in Sweden. Cell samples from genital swabs, first-void urine, and genital swabs immersed in first-void urine were collected in the present cross-sectional High Throughput HPV Monitoring study. Overall, 31,717 samples from women and 9,949 from men (mean age 25) were tested for 16 HPV types using mass spectrometry. Multilevel logistic regression was used to estimate the expected number of multiple infections with specific HPV types, adjusted for age, type of sample, and accounting for correlations between HPV types due to unobserved risk factors using sample-level random effects. Bonferroni correction was used to allow for multiple comparisons (120). Observed-to-expected ratio for any multiple infections was slightly above unity in both sexes, but, for most 2-type combinations, there was no evidence of significant departure from expected numbers. HPV6/18 was found more often and HPV51/68 and 6/68 less often than expected. However, HPV68 tended to be generally underrepresented in co-infections, suggesting a sub-optimal performance of our testing method for this HPV type. We found no evidence for positive or negative clustering between HPV types included in the current prophylactic vaccines and other untargeted oncogenic types, in either sex.

  8. Urine Albumin-Creatinine Ratio Versus Albumin Excretion for Albuminuria Staging: A Prospective Longitudinal Cohort Study.

    PubMed

    Vart, Priya; Scheven, Lieneke; Lambers Heerspink, Hiddo J; de Jong, Paul E; de Zeeuw, Dick; Gansevoort, Ron T

    2016-01-01

    New guidelines advocate the use of albumin-creatinine ratio (ACR) in a urine sample instead of 24-hour urinary albumin excretion (UAE) for staging albuminuria. Concern has been expressed that this may result in misclassification for reasons including interindividual differences in urinary creatinine excretion. Prospective longitudinal cohort study. We examined 7,623 participants of the PREVEND and RENAAL studies for reclassified when using ACR instead of 24-hour UAE, the characteristics of reclassified participants, and their outcomes. Albuminuria was categorized into 3 ACR and UAE categories: <30, 30 to 300, and >300mg/g or mg/24 h, respectively. Baseline ACR and 24-hour UAE. Cardiovascular (CV) morbidity and mortality and all-cause mortality. When using ACR in the early morning void instead of 24-hour UAE, 88% of participants were classified in corresponding albuminuria categories. 307 (4.0%) participants were reclassified to a higher, and 603 (7.9%), to a lower category. Participants who were reclassified to a higher ACR category in general had a worse CV risk profile compared with nonreclassified participants, whereas the reverse was true for participants reclassified to a lower ACR category. Similarly, Cox proportional hazards regression analyses showed that reclassification to a higher ACR category was associated with a tendency for increased risk for CV morbidity and mortality and all-cause mortality, whereas reclassification to a lower ACR category was associated with a tendency for lower risk. Net reclassification improvement, adjusted for age, sex, and duration of follow-up, was 0.107 (P=0.002) for CV events and 0.089 (P<0.001) for all-cause mortality. Early morning void urine collection instead of spot urine collection. Our results indicate that there is high agreement between early morning void ACR and 24-hour UAE categories. Reclassification is therefore limited, but when present, is generally indicative of the presence of CV risk factors and prognosis. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  9. High performance of a new PCR-based urine assay for HPV-DNA detection and genotyping.

    PubMed

    Tanzi, Elisabetta; Bianchi, Silvia; Fasolo, Maria Michela; Frati, Elena R; Mazza, Francesca; Martinelli, Marianna; Colzani, Daniela; Beretta, Rosangela; Zappa, Alessandra; Orlando, Giovanna

    2013-01-01

    Human papillomavirus (HPV) testing has been proposed as a means of replacing or supporting conventional cervical screening (Pap test). However, both methods require the collection of cervical samples. Urine sample is easier and more acceptable to collect and could be helpful in facilitating cervical cancer screening. The aim of this study was to evaluate the sensitivity and specificity of urine testing compared to conventional cervical smear testing using a PCR-based method with a new, designed specifically primer set. Paired cervical and first voided urine samples collected from 107 women infected with HIV were subjected to HPV-DNA detection and genotyping using a PCR-based assay and a restriction fragment length polymorphism method. Sensitivity, specificity, Positive Predictive Value (PPV), and Negative Predictive Value (NPV) were calculated using the McNemar's test for differences. Concordance between tests was assessed using the Cohen's unweighted Kappa (k). HPV DNA was detected in 64.5% (95% CI: 55.1-73.1%) of both cytobrush and urine samples. High concordance rates of HPV-DNA detection (k = 0.96; 95% CI: 0.90-1.0) and of high risk-clade and low-risk genotyping in paired samples (k = 0.80; 95% CI: 0.67-0.92 and k = 0.74; 95% CI: 0.60-0.88, respectively) were observed. HPV-DNA detection in urine versus cervix testing revealed a sensitivity of 98.6% (95% CI: 93.1-99.9%) and a specificity of 97.4% (95% CI: 87.7-99.9%), with a very high NPV (97.4%; 95% CI: 87.7-99.9%). The PCR-based assay utilized in this study proved highly sensitive and specific for HPV-DNA detection and genotyping in urine samples. These data suggest that a urine-based assay would be a suitable and effective tool for epidemiological surveillance and, most of all, screening programs. Copyright © 2012 Wiley Periodicals, Inc.

  10. Stress urinary incontinence

    MedlinePlus

    ... leakage and fluid intake. Pelvic or abdominal ultrasound . Post-void residual (PVR) to measure the amount of urine left after you urinate. Urinalysis to check for urinary tract infection. Urinary stress test: You stand with a full bladder and then ...

  11. Defining the "normal" postejaculate urinalysis.

    PubMed

    Mehta, Akanksha; Jarow, Jonathan P; Maples, Pat; Sigman, Mark

    2012-01-01

    Although sperm have been shown to be present in the postejaculate urinalysis (PEU) of both fertile and infertile men, the number of sperm present in the PEU of the general population has never been well defined. The objective of this study was to describe the semen and PEU findings in both the general and infertile population, in order to develop a better appreciation for "normal." Infertile men (n = 77) and control subjects (n = 71) were prospectively recruited. Exclusion criteria included azoospermia and medications known to affect ejaculation. All men underwent a history, physical examination, semen analysis, and PEU. The urine was split into 2 containers: PEU1, the initial voided urine, and PEU2, the remaining voided urine. Parametric statistical methods were applied for data analysis to compare sperm concentrations in each sample of semen and urine between the 2 groups of men. Controls had higher average semen volume (3.3 ± 1.6 vs 2.0 ± 1.4 mL, P < .001) and sperm concentrations (112 million vs 56.2 million, P = .011), compared with infertile men. The presence of sperm in urine was common in both groups, but more prevalent among infertile men (98.7% vs 88.7%, P = .012), in whom it comprised a greater proportion of the total sperm count (46% vs 24%, P = .022). The majority of sperm present in PEU were seen in PEU1 of both controls (69%) and infertile men (88%). An association was noted between severe oligospermia (<5 million/mL) with low semen volume (<0.5 mL), and significant sperm counts in PEU (<5 million). Although infertile men tend to have a higher proportion of their total sperm in the urine compared with control, there is a large degree of overlap between the 2 populations, making it difficult to identify a specific threshold to define a positive test. Interpretation of a PEU should be directed by whether the number of sperm in the urine could affect subsequent management.

  12. A disposable adhesive patch for stress urinary incontinence.

    PubMed

    North, B B

    1998-04-01

    Stress urinary incontinence (SUI) affects 5 million women in the United States. Current surgical and pharmacological management options are often unsuccessful, forcing many sufferers to rely on bulky and uncomfortable sanitary protection. This study evaluated the safety, efficacy, and acceptability of a small, disposable adhesive patch designed to seal the urethral opening and prevent urine leakage. Thirty-seven women with mild-to-moderate SUI were recruited from a suburban community. Each volunteer participated in a 21-week protocol that included a 1-week qualifying period, 4-week (pretest) control period, 12-week patch-use period, and 4-week (posttest) control period. Patch efficacy was evaluated with quantitative (leakage into sanitary napkin) and qualitative (voiding diary) measures of urine leakage. Symptom questionnaires were also completed. Overall leakage was reduced by 60%, from 1.1 +/- .3 standard error of the mean (SEM) to .44 +/- .11 (SEM) grams of urine per hour. Perception of dryness, measured by voiding diaries, improved 67%, from 13.3 +/- 1.9 (SEM) to 4.3 +/- 0.9 (SEM) leakage episodes per week. Safety evaluation included peri-urethral cytology, urinalysis and urine culture, and vaginal cultures. All measures were unaffected by 3 months of patch use. Acceptability was assessed with questionnaires that measured the impact of patch use on activities of daily living and overall quality of life. Women reported a significant improvement in both measures. All but one volunteer found that the patch was comfortable and were able to place it correctly between the inner labia with written instructions only. The disposable patch significantly reduced urine leakage resulting from SUI in community-based women. Dryness improved significantly, both by measurement of actual leakage and by the subject's perception of dryness. The maturation index of the vestibular tissues showed an increase in the number of superficial cells during patch use. Otherwise, there were no significant changes in vulvar tissues, urine composition, or microbial flora (in vaginal and urine samples). Volunteers reported that the patch improved their overall quality of life.

  13. Urine podocyte mRNAs mark disease activity in IgA nephropathy

    PubMed Central

    Fukuda, Akihiro; Sato, Yuji; Iwakiri, Takashi; Komatsu, Hiroyuki; Kikuchi, Masao; Kitamura, Kazuo; Wiggins, Roger C.; Fujimoto, Shouichi

    2015-01-01

    Background Podocyte depletion is a major mechanism driving glomerulosclerosis. We and others have previously projected from model systems that podocyte-specific mRNAs in the urine pellet might serve as glomerular disease markers. We evaluated IgA nephropathy (IgAN) to test this concept. Methods From 2009 to 2013, early morning voided urine samples and kidney biopsies from IgAN patients (n = 67) were evaluated in comparison with urine samples from healthy age-matched volunteers (n = 28). Urine podocyte (podocin) mRNA expressed in relation to either urine creatinine concentration or a kidney tubular marker (aquaporin 2) was tested as markers. Results Urine podocyte mRNAs were correlated with the severity of active glomerular lesions (segmental glomerulosclerosis and acute extracapillary proliferation), but not with non-glomerular lesions (tubular atrophy/interstitial fibrosis) or with clinical parameters of kidney injury (serum creatinine and estimated glomerular filtration rate), or with degree of accumulated podocyte loss at the time of biopsy. In contrast, proteinuria correlated with all histological and clinical markers. Glomerular tuft podocyte nuclear density (a measure of cumulative podocyte loss) correlated with tubular atrophy/interstitial fibrosis, estimated-glomerular filtration rate and proteinuria, but not with urine podocyte markers. In a subset of the IgA cohort (n = 19, median follow-up period = 37 months), urine podocyte mRNAs were significantly decreased after treatment, in contrast to proteinuria which was not significantly changed. Conclusions Urine podocyte mRNAs reflect active glomerular injury at a given point in time, and therefore provide both different and additional clinical information that can complement proteinuria in the IgAN decision-making paradigm. PMID:25956757

  14. Distribution, variability, and predictors of urinary bisphenol A levels in 50 North Carolina adults over a six-week monitoring period.

    PubMed

    Morgan, Marsha K; Nash, Maliha; Barr, Dana Boyd; Starr, James M; Scott Clifton, M; Sobus, Jon R

    2018-03-01

    Bisphenol A (BPA) is commonly manufactured to make polycarbonate plastics and epoxy resins for use in consumer products and packaged goods. BPA has been found in several different types of environmental media (e.g., food, dust, and air). Many cross-sectional studies have frequently detected BPA concentrations in adult urine samples. However, limited data are available on the temporal variability and important predictors of urinary BPA concentrations in adults. In this work, the major objectives were to: 1) quantify BPA levels in duplicate-diet solid food, drinking water, hard floor surface wipe, and urine samples (first-morning void [FMV], bedtime, and 24-h) collected from adults over a six-week monitoring period; 2) determine the temporal variability of urinary BPA levels using concentration, specific gravity (SG) adjusted, creatinine (CR) adjusted, and excretion rate values, and; 3) examine associations between available study factors and urinary BPA concentrations. In 2009-2011, a convenience sample of 50 adults was recruited from residential settings in North Carolina. The participants completed diaries and collected samples during weeks 1, 2, and/or 6 of a six-week monitoring period. BPA was detected in 38%, 4%, and 99% of the solid food (n=775), drinking water (n=50), and surface wipe samples (n=138), respectively. Total BPA (free plus conjugated) was detected in 98% of the 2477 urine samples. Median urinary BPA levels were 2.07ng/mL, 2.20ng/mL-SG, 2.29ng/mg, and 2.31ng/min for concentration, SG-adjusted, CR-adjusted, and excretion rate values, respectively. The intraclass correlation coefficient (ICC) estimates for BPA showed poor reproducibility (≤0.35) for all urine sample types and methods over a day, week, and six weeks. CR-adjusted bedtime voids collected over six-weeks required the fewest, realistic number of samples (n=11) to obtain a reliable biomarker estimate (ICC=0.80). Results of linear mixed-effects models showed that sex, race, season, and CR-level were all significant predictors (p<0.05) of the adults' urinary BPA concentrations. BPA levels in the solid food and surface wipe samples did not contribute significantly to the participants' urinary BPA concentrations. However, a significant positive relationship was observed between solid food intake and urine-based estimates of BPA dose, when aggregated over 24-h periods. Ingestion of BPA via solid food explained only about 20% of the total dose (at the median of the dose distribution), suggesting that these adults were likely exposed to other major unknown (non-dietary) sources of BPA in their everyday environments. Published by Elsevier Ltd.

  15. Relationship between blood and urine alcohol concentrations in apprehended drivers who claimed consumption of alcohol after driving with and without supporting evidence.

    PubMed

    Jones, Alan Wayne; Kugelberg, Fredrik C

    2010-01-30

    For various reasons, many people suspected of driving under the influence of alcohol (DUIA) are not apprehended sitting behind the wheel, but some time after the driving. This gives them the opportunity to claim they drank alcohol after the time of driving or after they were involved in a road-traffic crash. Alleged post-offence drinking is not easy for the prosecution to disprove, which often means that the DUIA charge is dropped or the person is acquitted if the case goes to trial. The routine practice of sampling and measuring the concentration of alcohol in blood (BAC) and urine (UAC) and calculating urine/blood ratios (UAC/BAC) and the changes in UAC between two successive voids furnishes useful information to support or challenge alleged drinking after driving. We present here a retrospective case series of DUIA offenders (N=40) in half of which there was supporting evidence of an after-drink (eye witness or police reports) and in the other half no such evidence existed apart from the suspect's admission. When there was supporting evidence of an after-drink, the UAC/BAC ratio for the first void was close to or less than unity (mean 1.04, median 1.08, range 0.54-1.21) and the UAC increased by 0.21 g/L (range 0.02-0.57) between the two voids. Without any supporting evidence of post-offence drinking the mean UAC/BAC ratio was 1.46 (range 1.35-1.93) for the first void, verifying that absorption and distribution of alcohol in all body fluids and tissues was complete. In these cases, the UAC between successive voids decreased by 0.25 g/L on average (range 0.10-0.49), indicating the post-absorptive phase of the BAC curve. Long experience from investigating claims of post-offence drinking leads us to conclude that in the vast majority of cases this lacks any substance and is simply a last resort by DUIA offenders to evade justice. Unless supporting evidence exists (eye witness, police reports, etc.) of post-offence drinking the courts are encouraged to ignore this defence argument. 2009 Elsevier Ireland Ltd. All rights reserved.

  16. 49 CFR 40.65 - What does the collector check for when the employee presents a specimen?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.65.... You must check to ensure that the specimen contains at least 45 mL of urine. (1) If it does not, you... of tampering) also exists. (3) You are never permitted to combine urine collected from separate voids...

  17. 49 CFR 40.65 - What does the collector check for when the employee presents a specimen?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.65.... You must check to ensure that the specimen contains at least 45 mL of urine. (1) If it does not, you... of tampering) also exists. (3) You are never permitted to combine urine collected from separate voids...

  18. 49 CFR 40.65 - What does the collector check for when the employee presents a specimen?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.65.... You must check to ensure that the specimen contains at least 45 mL of urine. (1) If it does not, you... of tampering) also exists. (3) You are never permitted to combine urine collected from separate voids...

  19. 49 CFR 40.65 - What does the collector check for when the employee presents a specimen?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.65.... You must check to ensure that the specimen contains at least 45 mL of urine. (1) If it does not, you... of tampering) also exists. (3) You are never permitted to combine urine collected from separate voids...

  20. 49 CFR 40.65 - What does the collector check for when the employee presents a specimen?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Urine Specimen Collections § 40.65.... You must check to ensure that the specimen contains at least 45 mL of urine. (1) If it does not, you... of tampering) also exists. (3) You are never permitted to combine urine collected from separate voids...

  1. Recovery of storage and emptying functions of the urinary bladder after spinal anesthesia with lidocaine and with bupivacaine in men.

    PubMed

    Kamphuis, E T; Ionescu, T I; Kuipers, P W; de Gier, J; van Venrooij, G E; Boon, T A

    1998-02-01

    The aim of this study was to evaluate and compare the effects of spinal anesthesia with lidocaine and with bupivacaine on urinary bladder function in healthy men who were scheduled for minor orthopaedic surgical procedures. Twenty men were randomly allocated to receive either bupivacaine or lidocaine. Before spinal anesthesia, filling cystometry was performed with the patient in the supine position and a pressure flow study was done with the patient in the standing position. After operation, cystometric measurements were continued until the patient could void urine spontaneously. The levels of analgesia and of motor blockade were recorded. The urge to void disappeared immediately after injection of the local anesthetics. There was no difference in the duration of lower extremity motor blockade between bupivacaine and lidocaine. Detrusor blockade lasted significantly longer in the bupivacaine group (means +/- SD, 460 +/- 60 min) than in the lidocaine group (235 +/- 30 min). Total fluid intake and urine volume accumulated during the detrusor blockade were significantly higher in the bupivacaine group than in the lidocaine group. In the bupivacaine group, the total volume of accumulated urine (875 +/- 385 ml) was also significantly higher than cystometric bladder capacity (505 +/- 120 ml) with the risk of over distension of the bladder. Spontaneous voiding of urine did not occur until segmental sensory analgesia had regressed to the third sacral segment. Spinal anesthesia with lidocaine and with bupivacaine causes a clinically significant disturbance of bladder function due to interruption of the micturition reflex. The urge to void disappears quickly and bladder function remains impaired until the block has regressed to the third sacral segment in all patients. With long-acting local anesthetics, the volume of accumulated urine may exceed the cystometric bladder capacity. With respect to recovery of urinary bladder function, the use of short-acting local anesthetics for spinal anesthesia seems to be preferable.

  2. Comparative Study of Seven Commercial Kits for Human DNA Extraction from Urine Samples Suitable for DNA Biomarker-Based Public Health Studies

    PubMed Central

    El Bali, Latifa; Diman, Aurélie; Bernard, Alfred; Roosens, Nancy H. C.; De Keersmaecker, Sigrid C. J.

    2014-01-01

    Human genomic DNA extracted from urine could be an interesting tool for large-scale public health studies involving characterization of genetic variations or DNA biomarkers as a result of the simple and noninvasive collection method. These studies, involving many samples, require a rapid, easy, and standardized extraction protocol. Moreover, for practicability, there is a necessity to collect urine at a moment different from the first void and to store it appropriately until analysis. The present study compared seven commercial kits to select the most appropriate urinary human DNA extraction procedure for epidemiological studies. DNA yield has been determined using different quantification methods: two classical, i.e., NanoDrop and PicoGreen, and two species-specific real-time quantitative (q)PCR assays, as DNA extracted from urine contains, besides human, microbial DNA also, which largely contributes to the total DNA yield. In addition, the kits giving a good yield were also tested for the presence of PCR inhibitors. Further comparisons were performed regarding the sampling time and the storage conditions. Finally, as a proof-of-concept, an important gene related to smoking has been genotyped using the developed tools. We could select one well-performing kit for the human DNA extraction from urine suitable for molecular diagnostic real-time qPCR-based assays targeting genetic variations, applicable to large-scale studies. In addition, successful genotyping was possible using DNA extracted from urine stored at −20°C for several months, and an acceptable yield could also be obtained from urine collected at different moments during the day, which is particularly important for public health studies. PMID:25365790

  3. Abnormal urinalysis results are common, regardless of specimen collection technique, in women without urinary tract infections.

    PubMed

    Frazee, Bradley W; Enriquez, Kayla; Ng, Valerie; Alter, Harrison

    2015-06-01

    Voided urinalysis to test for urinary tract infection (UTI) is prone to false-positive results for a number of reasons. Specimens are often collected at triage from women with any abdominal complaint, creating a low UTI prevalence population. Improper collection technique by the patient may affect the result. At least four indices, if positive, can indicate UTI. We examine the impact of voided specimen collection technique on urinalysis indicators of UTI and on urine culture contamination in disease-free women. In this crossover design, 40 menstrual-age female emergency department staff without UTI symptoms collected urine two ways: directly in a cup ("non-clean") and midstream clean catch ("ideal"). Samples underwent standard automated urinalysis and culture. Urinalysis indices and culture contamination were compared. The proportion of abnormal results from samples collected by "non-clean" vs. "ideal" technique, respectively, were: leukocyte esterase (>trace) 50%, 35% (95% confidence interval for difference -6% to 36%); nitrites (any) 2.5%, 2.5% (difference -2.5 to 2.5%); white blood cells (>5/high-powered field [HPF]) 50%, 27.5% (difference 4 to 41%); bacteria (any/HPF) 77.5%, 62.5%, (difference -7 to 37%); epithelial cells (>few) 65%, 30% (difference 13 to 56%); culture contamination (>1000 colony-forming units of commensal or >2 species) 77%, 63% (difference -5 to 35%). No urinalysis index was positively correlated with culture contamination. Contemporary automated urinalysis indices were often abnormal in a disease-free population of women, even using ideal collection technique. In clinical practice, such false-positive results could lead to false-positive UTI diagnosis. Only urine nitrite showed a high specificity. Culture contamination was common regardless of collection technique and was not predicted by urinalysis results. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. The effectiveness of dried cranberries ( Vaccinium macrocarpon) in men with lower urinary tract symptoms.

    PubMed

    Vidlar, Ales; Vostalova, Jitka; Ulrichova, Jitka; Student, Vladimir; Stejskal, David; Reichenbach, Richard; Vrbkova, Jana; Ruzicka, Filip; Simanek, Vilim

    2010-10-01

    Lower urinary tract symptoms (LUTS) are a common condition in older men. The objective of the present study was to evaluate the efficacy and tolerability of cranberry (Vaccinium macrocarpon) powder in men at risk of prostate disease with LUTS, elevated prostate-specific antigen (PSA), negative prostate biopsy and clinically confirmed chronic non-bacterial prostatitis. Forty-two participants received either 1500 mg of the dried powdered cranberries per d for 6 months (cranberry group; n 21) or no cranberry treatment (control group; n 21). Physical examination, International Prostate Symptom Score, quality of life (QoL), five-item version of the International Index of Erectile Function (IIEF-5), basic clinical chemistry parameters, haematology, Se, testosterone, PSA (free and total), C-reactive protein (CRP), antioxidant status, transrectal ultrasound prostate volume, urinary flow rate, ultrasound-estimated post-void residual urine volume at baseline, and at 3 and 6 months, and urine ex vivo anti-adherence activity were determined in all subjects. In contrast to the control group, patients in the cranberry group had statistically significant improvement in International Prostate Symptom Score, QoL, urination parameters including voiding parameters (rate of urine flow, average flow, total volume and post-void residual urine volume), and lower total PSA level on day 180 of the study. There was no influence on blood testosterone or serum CRP levels. There was no statistically significant improvement in the control group. The results of the present trial are the first firm evidence that cranberries may ameliorate LUTS, independent of benign prostatic hyperplasia or C-reactive protein level.

  5. A urine volume measurement system

    NASA Technical Reports Server (NTRS)

    Poppendiek, H. F.; Mouritzen, G.; Sabin, C. M.

    1972-01-01

    An improved urine volume measurement system for use in the unusual environment of manned space flight is reported. The system utilizes a low time-constant thermal flowmeter. The time integral of the transient response of the flowmeter gives the urine volume during a void as it occurs. In addition, the two phase flows through the flowmeter present no problem. Developments of the thermal flowmeter and a verification of the predicted performance characteristics are summarized.

  6. Human and methodological sources of variability in the measurement of urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine.

    PubMed

    Barregard, Lars; Møller, Peter; Henriksen, Trine; Mistry, Vilas; Koppen, Gudrun; Rossner, Pavel; Sram, Radim J; Weimann, Allan; Poulsen, Henrik E; Nataf, Robert; Andreoli, Roberta; Manini, Paola; Marczylo, Tim; Lam, Patricia; Evans, Mark D; Kasai, Hiroshi; Kawai, Kazuaki; Li, Yun-Shan; Sakai, Kazuo; Singh, Rajinder; Teichert, Friederike; Farmer, Peter B; Rozalski, Rafal; Gackowski, Daniel; Siomek, Agnieszka; Saez, Guillermo T; Cerda, Concha; Broberg, Karin; Lindh, Christian; Hossain, Mohammad Bakhtiar; Haghdoost, Siamak; Hu, Chiung-Wen; Chao, Mu-Rong; Wu, Kuen-Yuh; Orhan, Hilmi; Senduran, Nilufer; Smith, Raymond J; Santella, Regina M; Su, Yali; Cortez, Czarina; Yeh, Susan; Olinski, Ryszard; Loft, Steffen; Cooke, Marcus S

    2013-06-20

    Urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG) is a widely used biomarker of oxidative stress. However, variability between chromatographic and ELISA methods hampers interpretation of data, and this variability may increase should urine composition differ between individuals, leading to assay interference. Furthermore, optimal urine sampling conditions are not well defined. We performed inter-laboratory comparisons of 8-oxodG measurement between mass spectrometric-, electrochemical- and ELISA-based methods, using common within-technique calibrants to analyze 8-oxodG-spiked phosphate-buffered saline and urine samples. We also investigated human subject- and sample collection-related variables, as potential sources of variability. Chromatographic assays showed high agreement across urines from different subjects, whereas ELISAs showed far more inter-laboratory variation and generally overestimated levels, compared to the chromatographic assays. Excretion rates in timed 'spot' samples showed strong correlations with 24 h excretion (the 'gold' standard) of urinary 8-oxodG (rp 0.67-0.90), although the associations were weaker for 8-oxodG adjusted for creatinine or specific gravity (SG). The within-individual excretion of 8-oxodG varied only moderately between days (CV 17% for 24 h excretion and 20% for first void, creatinine-corrected samples). This is the first comprehensive study of both human and methodological factors influencing 8-oxodG measurement, providing key information for future studies with this important biomarker. ELISA variability is greater than chromatographic assay variability, and cannot determine absolute levels of 8-oxodG. Use of standardized calibrants greatly improves intra-technique agreement and, for the chromatographic assays, importantly allows integration of results for pooled analyses. If 24 h samples are not feasible, creatinine- or SG-adjusted first morning samples are recommended.

  7. Development of a prototype fluid volume measurement system. [for urine volume measurement on space missions

    NASA Technical Reports Server (NTRS)

    Poppendiek, H. F.; Sabin, C. M.; Meckel, P. T.

    1974-01-01

    The research is reported in applying the axial fluid temperature differential flowmeter to a urine volume measurement system for space missions. The fluid volume measurement system is described along with the prototype equipment package. Flowmeter calibration, electronic signal processing, and typical void volume measurements are also described.

  8. Urinary analysis reveals high deoxynivalenol exposure in pregnant women from Croatia.

    PubMed

    Sarkanj, Bojan; Warth, Benedikt; Uhlig, Silvio; Abia, Wilfred A; Sulyok, Michael; Klapec, Tomislav; Krska, Rudolf; Banjari, Ines

    2013-12-01

    In this pilot survey the levels of various mycotoxin biomarkers were determined in third trimester pregnant women from eastern Croatia. First void urine samples were collected and analysed using a "dilute and shoot" LC-ESI-MS/MS multi biomarker method. Deoxynivalenol (DON) and its metabolites: deoxynivalenol-15-glucuronide and deoxynivalenol-3-glucuronide were detected in 97.5% of the studied samples, partly at exceptionally high levels, while ochratoxin A was found in 10% of the samples. DON exposure was primarily reflected by the presence of deoxynivalenol-15-glucuronide with a mean concentration of 120 μg L(-1), while free DON was detected with a mean concentration of 18.3 μg L(-1). Several highly contaminated urine samples contained a third DON conjugate, tentatively identified as deoxynivalenol-7-glucuronide by MS/MS scans. The levels of urinary DON and its metabolites measured in this study are the highest ever reported, and 48% of subjects were estimated to exceed the provisional maximum tolerable daily intake (1 μg kg(-1) b.w.). Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Urethroscopy and urethral cytology in men with external genital condyloma.

    PubMed

    Fralick, R A; Malek, R S; Goellner, J R; Hyland, K M

    1994-03-01

    To develop guidelines as to which asymptomatic male patients with genital human papillomavirus (HPV) infection need further evaluation of the urethra, we studied two screening methods: urethroscopy and voided urethral cytology. In a four-year period, 135 asymptomatic men underwent complete screening for HPV infection. They were evaluated because of HPV-related genital disease in their female sex partners or visible genital lesions, or both. Of the 135 patients, 21 (16%) had no clinical, subclinical, cytologic, or urethroscopic evidence of disease, and 114 (84%) had biopsy-proven HPV infection. Of these 114 patients, only 14 (12.3%) had intraurethral condyloma. All of these 14 patients had current or historical evidence of meatal or perimeatal "sentinel" lesions. They constituted 29.8 percent of 47 such patients with sentinel lesions. In 5 patients (4%), results of voided urine cytology were positive for condyloma cells, but only 1 of these had visible intraurethral disease. Of the 14 patients with urethral disease, only 1 (7%) had positive results of urine cytology. These observations suggest that any asymptomatic male patient undergoing screening for condyloma acuminatum who has a history of or demonstrable subclinical or grossly visible perimeatal or meatal HPV infection should undergo urethroscopy and that voided urine cytology is not a reliable or cost-effective test for the detection of visible intraurethral disease.

  10. Micturition patterns of an unrestrained chimpanzee under entrained and free running conditions.

    NASA Technical Reports Server (NTRS)

    Hoshizaki, T.; Mcnew, J. J.; Sabbot, I.; Adey, W. R.

    1972-01-01

    A young male chimpanzee was subjected to 30 days of isolation. Urine volumes and voiding times were recorded every hour beginning 14 days prior to isolation, ending 6 days after isolation, and approximately 2 months later for 10 days as a control. Observed during most periods of the experiment were (1) clear circadian micturition rhythms with the voiding peak occurring immediately after the subject awoke and (2) urine flow rhythms with the maximum volume voided in the morning hours. A 24-hour rhythm was seen when the subject was entrained to 12L:12D treatments and 24.8-hour rhythm when he was exposed to continuous light. A possible underlying 24-hour micturition rhythm was also seen during the continuous light period. Distorted rhythm curves indicating possible stress were obtained for the pre-isolation adaptation period and the initial period of isolation. As time passed, the curves were more like the controls, perhaps indicating a decrease in stress.

  11. Comparison of population iodine estimates from 24-hour urine and timed-spot urine samples.

    PubMed

    Perrine, Cria G; Cogswell, Mary E; Swanson, Christine A; Sullivan, Kevin M; Chen, Te-Ching; Carriquiry, Alicia L; Dodd, Kevin W; Caldwell, Kathleen L; Wang, Chia-Yih

    2014-04-01

    Median urine iodine concentration (UIC; μg/L) in spot urine samples is recommended for monitoring population iodine status. Other common measures are iodine:creatinine ratio (I/Cr; μg/g) and estimated 24-hour urine iodine excretion (UIE; I/Cr × predicted 24-hour Cr; μg/day). Despite different units, these measures are often used interchangeably, and it is unclear how they compare with the reference standard 24-hour UIE. Volunteers aged 18-39 years collected all their urine samples for 24 hours (n=400). Voids from morning, afternoon, evening, overnight, and a composite 24-hour sample were analyzed for iodine. We calculated median observed 24-hour UIE and 24-hour UIC, and spot UIC, I/Cr, and two measures of estimated UIE calculated using predicted 24-hour Cr from published estimates by Kesteloot and Joosens (varies by age and sex) and published equations by Mage et al. (varies by age, sex, race, and anthropometric measures). We examined mean differences and relative difference across iodine excretion levels using Bland-Altman plots. Median 24-hour UIE was 173.6 μg/day and 24-hour UIC was 144.8 μg/L. From timed-spot urine samples, estimates were: UIC 147.3-156.2 μg/L; I/Cr 103.6-114.3 μg/g, estimated 24-hour UIE (Kesteloot and Joosens) 145.7-163.3 μg/day; and estimated 24-hour UIE (Mage) 176.5-187.7 μg/day. Iodine measures did not vary consistently by timing of spot urine collection. Compared with observed 24-hour UIE, on average, estimated (Mage) 24-hour UIE was not significantly different, while estimated 24-hour UIE (Kesteloot and Joosens) was significantly different for some ethnicity/sex groups. Compared with 24-hour UIC, on average, spot UIC did not differ. Estimates of UIC, I/Cr, and estimated 24-hour UIE (I/Cr × predicted 24-hour Cr) from spot urine samples should not be used interchangeably. Estimated 24-hour UIE, where predicted 24-hour Cr varies by age, sex, ethnicity, and anthropometric measures and was calculated with prediction equations using data from the sample, was more comparable to observed 24-hour UIE than when predicted 24-hour Cr was from published estimates from a different population. However, currently no cutoffs exist to interpret population estimated 24-hour UIE values.

  12. The human urinary microbiome; bacterial DNA in voided urine of asymptomatic adults

    PubMed Central

    Lewis, Debbie A.; Brown, Richard; Williams, Jon; White, Paul; Jacobson, S. Kim; Marchesi, Julian R.; Drake, Marcus J.

    2013-01-01

    The urinary microbiome of healthy individuals and the way it alters with ageing have not been characterized and may influence disease processes. Conventional microbiological methods have limited scope to capture the full spectrum of urinary bacterial species. We studied the urinary microbiota from a population of healthy individuals, ranging from 26 to 90 years of age, by amplification of the 16S rRNA gene, with resulting amplicons analyzed by 454 pyrosequencing. Mid-stream urine (MSU) was collected by the “clean-catch” method. Quantitative PCR of 16S rRNA genes in urine samples, allowed relative enumeration of the bacterial loads. Analysis of the samples indicates that females had a more heterogeneous mix of bacterial genera compared to the male samples and generally had representative members of the phyla Actinobacteria and Bacteroidetes. Analysis of the data leads us to conclude that a “core” urinary microbiome could potentially exist, when samples are grouped by age with fluctuation in abundance between age groups. The study also revealed age-specific genera Jonquetella, Parvimonas, Proteiniphilum, and Saccharofermentans. In conclusion, conventional microbiological methods are inadequate to fully identify around two-thirds of the bacteria identified in this study. Whilst this proof-of-principle study has limitations due to the sample size, the discoveries evident in this sample data are strongly suggestive that a larger study on the urinary microbiome should be encouraged and that the identification of specific genera at particular ages may be relevant to pathogenesis of clinical conditions. PMID:23967406

  13. The human urinary microbiome; bacterial DNA in voided urine of asymptomatic adults.

    PubMed

    Lewis, Debbie A; Brown, Richard; Williams, Jon; White, Paul; Jacobson, S Kim; Marchesi, Julian R; Drake, Marcus J

    2013-01-01

    The urinary microbiome of healthy individuals and the way it alters with ageing have not been characterized and may influence disease processes. Conventional microbiological methods have limited scope to capture the full spectrum of urinary bacterial species. We studied the urinary microbiota from a population of healthy individuals, ranging from 26 to 90 years of age, by amplification of the 16S rRNA gene, with resulting amplicons analyzed by 454 pyrosequencing. Mid-stream urine (MSU) was collected by the "clean-catch" method. Quantitative PCR of 16S rRNA genes in urine samples, allowed relative enumeration of the bacterial loads. Analysis of the samples indicates that females had a more heterogeneous mix of bacterial genera compared to the male samples and generally had representative members of the phyla Actinobacteria and Bacteroidetes. Analysis of the data leads us to conclude that a "core" urinary microbiome could potentially exist, when samples are grouped by age with fluctuation in abundance between age groups. The study also revealed age-specific genera Jonquetella, Parvimonas, Proteiniphilum, and Saccharofermentans. In conclusion, conventional microbiological methods are inadequate to fully identify around two-thirds of the bacteria identified in this study. Whilst this proof-of-principle study has limitations due to the sample size, the discoveries evident in this sample data are strongly suggestive that a larger study on the urinary microbiome should be encouraged and that the identification of specific genera at particular ages may be relevant to pathogenesis of clinical conditions.

  14. Careful assessment key in managing prostatitis.

    PubMed

    Gujadhur, Rahul; Aning, Jonathan

    2015-04-01

    Prostatitis is a common condition estimated to affect up to 30% of men in their lifetime, it is most prevalent in men aged between 35 and 50. Prostatitis is subclassified into: acute bacterial prostatitis, chronic bacterial prostatitis, chronic pelvic pain and asymptomatic inflammatory prostatitis. Acute bacterial prostatitis presents with acute onset pelvic pain which may or may not be related to voiding, lower urinary tract symptoms, sometimes haematuria or haematospermia and systemic symptoms such as fever and rigors. A documented history of recurrent urinary tract infections is the key feature of chronic bacterial prostatitis. Duration of symptoms > 3 months defines chronicity. The key symptom of chronic pelvic pain syndrome is pain. Patients may describe pain during or after ejaculation as their predominant symptom. Clinical assessment includes a thorough history and examination. A digital rectal examination should be performed after a midstream urine (MSU) sample has been collected for urine dipstick, microscopy and culture. The prostate should be checked for nodules. In acute bacterial prostatitis the MSU is the only laboratory investigation required. Chronic pelvic pain syndrome may be multifactorial and part of a more generalised pain disorder. Pelvic floor muscle abnormalities, altered neuroendocrine pathways, chemically induced inflammation, bacterial infection, autoimmune processes, dysfunctional voiding as well intraprostatic ductal reflux mechanisms have all been identified in men with chronic pelvic pain syndrome.

  15. 5C.07: A METHOD TO ESTIMATE 24-HOUR SODIUM EXCRETION THROUGH SPOT URINE SAMPLES AND ITS APPLICATION VALUE FOR TARGET-ORGAN DAMAGE ASSESSMENT.

    PubMed

    Wang, H; Zhao, L; Xi, Y; Sun, N

    2015-06-01

    24-h urine sodium excretion is considered the most reliable method to evaluate the salt intakes. However, this method is cumbersome. So we want to develop formulas to estimate 24-h urinary sodium excretion using spot urinary samples in Chinese hypertensive population and explore the application value of this method in salt intake assessment and target organ damage. 1. We enrolled 510 cases of hospitalized patients with hypertension, 2/3 of them were arranged randomly to formula group to develop a new formula and the remainings were used to test the performance of the formula. All participants were instructed to collect a 24-h urine sample, a second morning voiding urine sample (SMU), and a post-meridiem urine sample in the late afternoon or early evening, prior to the evening meal (PMU). All samples were sent to measure sodium and creatinine concentration.2. We compared the differences of office blood pressure, 24-hour ambulatory blood pressure and left ventricular hypertrophy, vascular stiffness and urine protein among groups of different sodium intake. 24hour sodium excretion formulas was obtained using SMU and PMU respectively, which have good cosistency. The difference between the estimated and measured values in sodium excretion is 12.66mmol/day (SMU) and 9.41mmol/day (PM), to be equal to 0.7 g (SMU) and 0.6 g (PM) salt intake. Comparing with Kawasaki and Tanaka method, the new formula shows the lower degree of deviation, and higher accuracy and precision. Blood pressure of high urinary sodium group is higher than that in low urinary sodium group (P < 0.05). Left ventricular hypertrophy and urinary albumin/creatinine aggravated with the salt intake increase, this has eliminated the influence of other factors. All of morphologies of the relationship between ambulatory arterial stiffness index, pulse wave velocity and carotid intima-media thickness with quartiles of sodium intake resembled a J-shaped curve. In Chinese hypertensive population, the formulas to estimate 24-h urinary sodium using spot urinary samples spot urine are considered useful for estimating the mean level of population salt intake, and have a role in evaluating target organ damage.

  16. Urinary tract infections in infants and children: Diagnosis and management

    PubMed Central

    Robinson, Joan L; Finlay, Jane C; Lang, Mia Eileen; Bortolussi, Robert

    2014-01-01

    Recent studies have resulted in major changes in the management of urinary tract infections (UTIs) in children. The present statement focuses on the diagnosis and management of infants and children >2 months of age with an acute UTI and no known underlying urinary tract pathology or risk factors for a neurogenic bladder. UTI should be ruled out in preverbal children with unexplained fever and in older children with symptoms suggestive of UTI (dysuria, urinary frequency, hematuria, abdominal pain, back pain or new daytime incontinence). A midstream urine sample should be collected for urinalysis and culture in toilet-trained children; others should have urine collected by catheter or by suprapubic aspirate. UTI is unlikely if the urinalysis is completely normal. A bagged urine sample may be used for urinalysis but should not be used for urine culture. Antibiotic treatment for seven to 10 days is recommended for febrile UTI. Oral antibiotics may be offered as initial treatment when the child is not seriously ill and is likely to receive and tolerate every dose. Children <2 years of age should be investigated after their first febrile UTI with a renal/bladder ultrasound to identify any significant renal abnormalities. A voiding cystourethrogram is not required for children with a first UTI unless the renal/bladder ultrasound reveals findings suggestive of vesicoureteral reflux, selected renal anomalies or obstructive uropathy. PMID:25332662

  17. Urinary tract infections in infants and children: Diagnosis and management.

    PubMed

    Robinson, Joan L; Finlay, Jane C; Lang, Mia Eileen; Bortolussi, Robert

    2014-06-01

    Recent studies have resulted in major changes in the management of urinary tract infections (UTIs) in children. The present statement focuses on the diagnosis and management of infants and children >2 months of age with an acute UTI and no known underlying urinary tract pathology or risk factors for a neurogenic bladder. UTI should be ruled out in preverbal children with unexplained fever and in older children with symptoms suggestive of UTI (dysuria, urinary frequency, hematuria, abdominal pain, back pain or new daytime incontinence). A midstream urine sample should be collected for urinalysis and culture in toilet-trained children; others should have urine collected by catheter or by suprapubic aspirate. UTI is unlikely if the urinalysis is completely normal. A bagged urine sample may be used for urinalysis but should not be used for urine culture. Antibiotic treatment for seven to 10 days is recommended for febrile UTI. Oral antibiotics may be offered as initial treatment when the child is not seriously ill and is likely to receive and tolerate every dose. Children <2 years of age should be investigated after their first febrile UTI with a renal/bladder ultrasound to identify any significant renal abnormalities. A voiding cystourethrogram is not required for children with a first UTI unless the renal/bladder ultrasound reveals findings suggestive of vesicoureteral reflux, selected renal anomalies or obstructive uropathy.

  18. Temporal variability of pyrethroid metabolite levels in bedtime, morning, and 24-h urine samples for 50 adults in North Carolina.

    PubMed

    Morgan, Marsha K; Sobus, Jon R; Barr, Dana Boyd; Croghan, Carry W; Chen, Fu-Lin; Walker, Richard; Alston, Lillian; Andersen, Erik; Clifton, Matthew S

    2016-01-01

    Pyrethroid insecticides are widely used to control insects in both agricultural and residential settings worldwide. Few data are available on the temporal variability of pyrethroid metabolites in the urine of non-occupationally exposed adults. In this work, we describe the study design and sampling methodology for the Pilot Study to Estimate Human Exposures to Pyrethroids using an Exposure Reconstruction Approach (Ex-R study). Two major objectives were to quantify the concentrations of several pyrethroid metabolites in bedtime, first morning void (FMV), and 24-h urine samples as concentration (wet weight), specific-gravity (SG) corrected, creatinine (CR) corrected, and excretion rate values for 50 Ex-R adults over a six-week monitoring period and to determine if these correction approaches for urine dilution reduced the variability of the biomarker levels. The Ex-R study was conducted at the United States Environmental Protection Agency's Human Studies Facility in Chapel Hill, North Carolina USA and at participants' homes within a 40-mile radius of this facility. Recruitment of participants and field activities occurred between October 2009 and May 2011. Participants, ages 19-50 years old, provided daily food, activity, and pesticide-use diaries and collected their own urine samples (bedtime, FMV, and 24-h) during weeks 1, 2, and 6 of a six-week monitoring period. A total of 2503 urine samples were collected from the study participants. These samples were analyzed for the pyrethroid metabolites 3-phenoxybenzoic acid (3-PBA), cis/trans-3-(2,2-dichlorovinyl)-2,2-dimethyl-cyclopropane carboxylic acid (cis/trans-DCCA), and 2-methyl-3-phenylbenzoic acid (MPA) using high performance liquid chromatography/tandem mass spectrometry. Only 3-PBA was frequently detected (>50%) in the adult urine samples. Median urinary 3-PBA levels were 0.88 ng/mL, 0.96 ng/mL-SG, 1.04 ng/mg, and 1.04 ng/min for concentration, SG-corrected, CR-corrected, and excretion rate values, respectively, across all urine samples. The results showed that median urinary 3-PBA concentrations were consistently the lowest in FMV samples (0.77 ng/mL, 0.68 ng/mL-SG, 0.68 ng/mg, and 0.58 ng/min) and the highest in 24-h samples (0.92 ng/mL, 1.06 ng/mL-SG, 1.18 ng/mg, and 1.19 ng/min) across all four methods. Intraclass correlation coefficient (ICC) estimates for 3-PBA indicated poor reproducibility (<0.22) for all urine sample types and methods over a day, week, and six weeks. Correcting for urine sample dilution, based on either SG, CR or urine output, introduced additional measurement variability both between- and within-individuals. These results indicate that a single measure of urinary 3-PBA was not sufficient to characterize average exposure regardless of sample type, correction method, and time frame of collection. In addition, the study results can be used to inform the design of exposure characterization strategies in relevant environmental epidemiology studies in the future. Published by Elsevier Inc.

  19. Hormonal changes during 17 days of head-down bed-rest

    NASA Technical Reports Server (NTRS)

    Custaud, Marc-Antoine; Arnaud, Sara B.; Monk, Timothy H.; Claustrat, Bruno; Gharib, Claude; Gauquelin-Koch, Guillemette

    2003-01-01

    We investigated in six men the impact of 17 days of head-down bed rest (HDBR) on the daily rhythms of the hormones involved in hydroelectrolytic regulation. This HDBR study was designed to mimic a real space flight. Urine samples were collected at each voiding before, during and after HDBR. Urinary excretion of Growth Hormone (GH), Cortisol, 6 Sulfatoxymelatonin, Normetadrenaline (NMN) and Metadrenaline (NM) was determined. A decrease in urinary cortisol excretion during the night of HDBR was noted. For GH, a rhythm was found before and during HDBR. The rhythm of melatonin, evaluated with the urine excretion of 6 Sulfatoxymelatonin (aMT6S), the main hepatic metabolite, persisted throughout the experiment without any modification to the level of phase. A decrease during the night was noted for normetadrenaline urinary derivates, but only during the HDBR.

  20. 49 CFR Appendix C to Part 219 - Post-Accident Testing Specimen Collection

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... employee: two 10 ml grey-stoppered blood tubes and the Control Form. b. Ask the donor to complete STEP 1 on... the urine collection area. To the extent practical, all sources of water in the collection area should... standing water. c. The employee will be provided a private place in which to void. Urination will not be...

  1. Development of urine standard reference materials for metabolites of organic chemicals including polycyclic aromatic hydrocarbons, phthalates, phenols, parabens, and volatile organic compounds.

    PubMed

    Schantz, Michele M; Benner, Bruce A; Heckert, N Alan; Sander, Lane C; Sharpless, Katherine E; Vander Pol, Stacy S; Vasquez, Y; Villegas, M; Wise, Stephen A; Alwis, K Udeni; Blount, Benjamin C; Calafat, Antonia M; Li, Zheng; Silva, Manori J; Ye, Xiaoyun; Gaudreau, Éric; Patterson, Donald G; Sjödin, Andreas

    2015-04-01

    Two new Standard Reference Materials (SRMs), SRM 3672 Organic Contaminants in Smokers' Urine (Frozen) and SRM 3673 Organic Contaminants in Non-Smokers' Urine (Frozen), have been developed in support of studies for assessment of human exposure to select organic environmental contaminants. Collaborations among three organizations resulted in certified values for 11 hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and reference values for 11 phthalate metabolites, 8 environmental phenols and parabens, and 24 volatile organic compound (VOC) metabolites. Reference values are also available for creatinine and the free forms of caffeine, theobromine, ibuprofen, nicotine, cotinine, and 3-hydroxycotinine. These are the first urine Certified Reference Materials characterized for metabolites of organic environmental contaminants. Noteworthy, the mass fractions of the environmental organic contaminants in the two SRMs are within the ranges reported in population survey studies such as the National Health and Nutrition Examination Survey (NHANES) and the Canadian Health Measures Survey (CHMS). These SRMs will be useful as quality control samples for ensuring compatibility of results among population survey studies and will fill a void to assess the accuracy of analytical methods used in studies monitoring human exposure to these organic environmental contaminants.

  2. Development of urine standard reference materials for metabolites of organic chemicals including polycyclic aromatic hydrocarbons, phthalates, phenols, parabens, and volatile organic compounds

    PubMed Central

    Schantz, Michele M.; Benner, Bruce A.; Heckert, N. Alan; Sander, Lane C.; Sharpless, Katherine E.; Vander Pol, Stacy S.; Vasquez, Y.; Villegas, M.; Wise, Stephen A.; Alwis, K. Udeni; Blount, Benjamin C.; Calafat, Antonia M.; Li, Zheng; Silva, Manori J.; Ye, Xiaoyun; Gaudreau, Éric; Patterson, Donald G.; Sjödin, Andreas

    2016-01-01

    Two new Standard Reference Materials (SRMs), SRM 3672 Organic Contaminants in Smokers’ Urine (Frozen) and SRM 3673 Organic Contaminants in Non-Smokers’ Urine (Frozen), have been developed in support of studies for assessment of human exposure to select organic environmental contaminants. Collaborations among three organizations resulted in certified values for 11 hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and reference values for 11 phthalate metabolites, 8 environmental phenols and parabens, and 24 volatile organic compound (VOC) metabolites. Reference values are also available for creatinine and the free forms of caffeine, theobromine, ibuprofen, nicotine, cotinine, and 3-hydroxycotinine. These are the first urine Certified Reference Materials characterized for metabolites of organic environmental contaminants. Noteworthy, the mass fractions of the environmental organic contaminants in the two SRMs are within the ranges reported in population survey studies such as the National Health and Nutrition Examination Survey (NHANES) and the Canadian Health Measures Survey (CHMS). These SRMs will be useful as quality control samples for ensuring compatibility of results among population survey studies and will fill a void to assess the accuracy of analytical methods used in studies monitoring human exposure to these organic environmental contaminants. PMID:25651899

  3. Free uroflowmetry versus "Do-It-Yourself" uroflowmetry in the assessment of patients with lower urinary tract symptoms.

    PubMed

    Mombelli, Gabriella; Picozzi, Stefano; Messina, Giovanni; Truffelli, Dario; Marenghi, Carlo; Maffi, Gabriele; Carmignani, Luca

    2014-10-01

    We investigated the possibility that patients could carry out a urine flow assessment at home by themselves, in comfort, without expense and without the use of equipment. We compared this strategy of "Do-It-Yourself" (DIY) uroflowmetry with traditional, hospital uroflowmetry. One hundred and twenty patients were enrolled. The patients underwent conventional, free uroflowmetry in hospital. Subsequently, the patients were asked to carry out the following procedure at home: urinate into a graduated container to quantify the total voided volume and determine the flow time by measuring the duration of miction with a stopwatch or simply with the second hand of a clock. This procedure had to be performed three times without preparation. Hundred patients completed the study. The mean age of the patients analysed was 64.12 years. Their free uroflowmetry values were as follows: the mean voiding time was 44.28 s, the mean voided volume was 290.92 ml, the mean Qmax was 15.17 ml/s, the mean Qmean was 7.87 ml/s, and the mean post-void residual volume was 78.44 ml. The mean Qmean measured by the "DIY-uroflowmetry" was 8.33 ml/s, which was not statistically significantly different (P = 0.12). Assuming that pathological hospital uroflowmetry values are equivalent to a DIY-Qmean ≤10 ml/s and that normal hospital values are equivalent to a DIY-Qmean >10 ml/s, the concordance was 100 %. Our proposed DIY evaluation of urine flow, together with the International Prostatic Symptom Score (IPSS), provides a good estimate of the results of free uroflowmetry, enabling unnecessary hospital investigations to be avoided.

  4. Effectiveness of an anti-inflammatory drug, loxoprofen, for patients with nocturia.

    PubMed

    Saito, Motoaki; Kawatani, Masahito; Kinoshita, Yukako; Satoh, Keisuke; Miyagawa, Ikuo

    2005-08-01

    There is increasing evidence that non-steroidal anti-inflammatory drugs are effective for the treatment of nocturia. In this study, we attempted to investigate the role of loxoprofen sodium (loxoprofen) in the therapeutic management of patients with nocturia. Fifteen benign protastatic hyperplasia and/or overactive bladder patients (13 males and 2 females, 71.1 +/- 1.5 years old) with three or more voids per night were involved. These patients had received standard drug therapy. Although these patients had received standard drug therapy for more than half a year, they had still three or more episodes of nocturia. The patients took a single dose of 60 mg of loxoprofen at night prior to sleep. Before and 1 week after the initiation of this therapy, the effects of this treatment were assessed by frequency volume chart and a questionnaire. In the questionnaire, seven patients answered as excellent, six patients demonstrated improvement of their symptoms, two patients did not show a significant change in their symptoms and no patients demonstrated a deterioration in the symptoms. In frequency volume chart, total void per day, total void per night, total urine volume per day, total night urine volume per day and single voided volume in the night before and after this treatment were 9.97 +/- 0.81 and 8.99 +/- 0.74 per day, 3.82 +/- 0.25 and 1.82 +/- 0.27 per night, 1349 +/- 81 and 1258 +/- 91 mL per day, 567 +/- 46 and 325 +/- 51 mL per night, and 143 +/- 13 and 149 +/- 10 mL, respectively. Loxoprofen can be effective and useful for patients with nocturia. Our data suggest that the main mechanism of this effect is to decrease urine production during a night's sleep.

  5. Exposure to organophosphate flame retardants of hotel room attendants in Wuhan City, China.

    PubMed

    Tao, Yun; Shang, Yinzhu; Li, Jing; Feng, Jingwen; He, Zhenyu; Covaci, Adrian; Wang, Peng; Luo, Jing; Mao, Xiang; Shi, Bin; Hu, Liqin; Luo, Dan; Mei, Surong

    2018-05-01

    Indoor environments provide sources of exposure to organophosphate flame retardants (PFRs), which are artificially synthesized fire-protecting agents used as additives in interior products. As public spaces, hotels are required to meet stricter fire-precaution criteria. As such, room attendants may be exposed to higher levels of PFRs. Our goal was to characterize the exposure of hotel room attendants to PFRs by measuring metabolites in their urine and the corresponding parent PFRs in dust and hand-wipes collected from 27 hotels located in Wuhan City, China. The exposure of the attendants was found to be omnipresent: urinary metabolites of PFRs, such as DPHP (diphenyl phosphate), BDCIPP (bis(1,3-dichloro-2-propyl) phosphate), and DoCP (di-o-cresyl phosphate) & DpCP (di-p-cresyl phosphate) were detected with high frequency (87%, 79% and 87%, respectively). We observed that metabolites in post-shift urine were consistently present at higher levels than those in the first morning voids (p < 0.05 for BDCIPP and DPHP). Regarding external exposure, 10 PFRs were determined in both dust samples and hand-wipes, with TCIPP (tris(2-chloroisopropyl) phosphate) being the most abundant compound in both matrices. The levels of PFRs in hand-wipes and dust samples were not correlated. PFRs in dust and their corresponding urinary metabolites were not significantly correlated, while a moderate significant correlation of TDCIPP (tris(1,3-dichloro-2-propyl) phosphate) in hand-wipes and its urinary metabolite, BDCIPP, was observed in both morning void samples (p = 0.01) and post-shift urine (p = 0.002). Moreover, we found that participants from high-rise buildings (defined as > 7 stories) had significantly higher BDCIPP and DPHP concentrations than those from low-rise buildings. A possible reason is that high-rise buildings may use high-grade fireproof building materials to meet stricter fire restrictions. Overall, these results indicate that PFRs exposure in hotels is a contributor to the personal exposure of hotel room attendants. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Low dose oral desmopressin for nocturnal polyuria in patients with benign prostatic hyperplasia: a double-blind, placebo controlled, randomized study.

    PubMed

    Wang, Chung-Jing; Lin, Yu-Nan; Huang, Shi-Wei; Chang, Chien-Hsing

    2011-01-01

    We evaluated the long-term efficacy and safety of low dose oral desmopressin in elderly patients with benign prostatic hyperplasia with more than nocturnal voids and nocturnal polyuria more than 30% of total daily urine volume. Eligible patients with benign prostatic hyperplasia older than 65 years with nocturia, nocturnal polyuria and International Prostate Symptom Score 14 or greater were included in the study. All patients received placebo or 0.1 mg desmopressin orally at bedtime. Patients were required to visit the outpatient clinic from the first visit, and after 1, 3, 6 and 12 months of treatment. Patients maintained flow volume charts and used diaries to record voiding data throughout the study. During followup urinalysis, urine sodium, urine osmolality, serum electrolytes, prostate specific antigen, International Prostate Symptom Score, quality of life, transrectal ultrasonography of prostate, uroflowmetry and post-void residual urine volume were performed at each visit. A total of 115 patients were enrolled in the study and randomized as 58 in the placebo group and 57 in the desmopressin group. Desmopressin significantly decreased nocturnal urine output and the number of nocturia episodes, and prolonged the first sleep period (p < 0.01). Compared to before treatment desmopressin gradually decreased serum sodium and induced statistically but not clinically significant hyponatremia after 12 months of treatment. No serious systemic complications were found during medication. Low dose oral desmopressin is an effective and well tolerated treatment for nocturnal polyuria in the lower urinary tract symptoms of patients with benign prostatic hyperplasia. Long-term desmopressin therapy gradually decreases serum sodium and it might induce hyponatremia even in patients without initial hyponatremia. For long-term desmopressin administration serum sodium should be assessed carefully, at least at 1 week after treatment. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  7. Effectiveness of Preanalytic Practices on Contamination and Diagnostic Accuracy of Urine Cultures: a Laboratory Medicine Best Practices Systematic Review and Meta-analysis

    PubMed Central

    Franek, Jacob; Leibach, Elizabeth K.; Weissfeld, Alice S.; Kraft, Colleen S.; Sautter, Robert L.; Baselski, Vickie; Rodahl, Debra; Peterson, Edward J.; Cornish, Nancy E.

    2015-01-01

    SUMMARY Background. Urinary tract infection (UTI) in the United States is the most common bacterial infection, and urine cultures often make up the largest portion of workload for a hospital-based microbiology laboratory. Appropriately managing the factors affecting the preanalytic phase of urine culture contributes significantly to the generation of meaningful culture results that ultimately affect patient diagnosis and management. Urine culture contamination can be reduced with proper techniques for urine collection, preservation, storage, and transport, the major factors affecting the preanalytic phase of urine culture. Objectives. The purposes of this review were to identify and evaluate preanalytic practices associated with urine specimens and to assess their impact on the accuracy of urine culture microbiology. Specific practices included collection methods for men, women, and children; preservation of urine samples in boric acid solutions; and the effect of refrigeration on stored urine. Practice efficacy and effectiveness were measured by two parameters: reduction of urine culture contamination and increased accuracy of patient diagnosis. The CDC Laboratory Medicine Best Practices (LMBP) initiative's systematic review method for assessment of quality improvement (QI) practices was employed. Results were then translated into evidence-based practice guidelines. Search strategy. A search of three electronic bibliographic databases (PubMed, SCOPUS, and CINAHL), as well as hand searching of bibliographies from relevant information sources, for English-language articles published between 1965 and 2014 was conducted. Selection criteria. The search contained the following medical subject headings and key text words: urinary tract infections, UTI, urine/analysis, urine/microbiology, urinalysis, specimen handling, preservation, biological, preservation, boric acid, boric acid/borate, refrigeration, storage, time factors, transportation, transport time, time delay, time factor, timing, urine specimen collection, catheters, indwelling, urinary reservoirs, continent, urinary catheterization, intermittent urethral catheterization, clean voided, midstream, Foley, suprapubic, bacteriological techniques, and microbiological techniques. Main results. Both boric acid and refrigeration adequately preserved urine specimens prior to their processing for up to 24 h. Urine held at room temperature for more than 4 h showed overgrowth of both clinically significant and contaminating microorganisms. The overall strength of this body of evidence, however, was rated as low. For urine specimens collected from women, there was no difference in rates of contamination for midstream urine specimens collected with or without cleansing. The overall strength of this evidence was rated as high. The levels of diagnostic accuracy of midstream urine collection with or without cleansing were similar, although the overall strength of this evidence was rated as low. For urine specimens collected from men, there was a reduction in contamination in favor of midstream clean-catch over first-void specimen collection. The strength of this evidence was rated as high. Only one study compared midstream collection with cleansing to midstream collection without cleansing. Results showed no difference in contamination between the two methods of collection. However, imprecision was due largely to the small event size. The diagnostic accuracy of midstream urine collection from men compared to straight catheterization or suprapubic aspiration was high. However, the overall strength of this body of evidence was rated as low. For urine specimens collected from children and infants, the evidence comparing contamination rates for midstream urine collection with cleansing, midstream collection without cleansing, sterile urine bag collection, and diaper collection pointed to larger reductions in the odds of contamination in favor of midstream collection with cleansing over the other methods of collection. This body of evidence was rated as high. The accuracy of diagnosis of urinary tract infection from midstream clean-catch urine specimens, sterile urine bag specimens, or diaper specimens compared to straight catheterization or suprapubic aspiration was varied. Authors' conclusions. No recommendation for or against is made for delayed processing of urine stored at room temperature, refrigerated, or preserved in boric acid. This does not preclude the use of refrigeration or chemical preservatives in clinical practice. It does indicate, however, that more systematic studies evaluating the utility of these measures are needed. If noninvasive collection is being considered for women, midstream collection with cleansing is recommended, but no recommendation for or against is made for midstream collection without cleansing. If noninvasive collection is being considered for men, midstream collection with cleansing is recommended and collection of first-void urine is not recommended. No recommendation for or against is made for collection of midstream urine without cleansing. If noninvasive collection is being considered for children, midstream collection with cleansing is recommended and collection in sterile urine bags, from diapers, or midstream without cleansing is not recommended. Whether midstream collection with cleansing can be routinely used in place of catheterization or suprapubic aspiration is unclear. The data suggest that midstream collection with cleansing is accurate for the diagnosis of urinary tract infections in infants and children and has higher average accuracy than sterile urine bag collection (data for diaper collection were lacking); however, the overall strength of evidence was low, as multivariate modeling could not be performed, and thus no recommendation for or against can be made. PMID:26598386

  8. α1-Blockers for the treatment of recurrent urinary tract infections in women with dysfunctional voiding: a prospective randomized study.

    PubMed

    Minardi, Daniele; Pellegrinelli, Francesco; Conti, Alessandro; Fontana, Donatella; Mattia, Michela; Milanese, Giulio; Muzzonigro, Giovanni

    2015-01-01

    To evaluate the therapeutic effects of tamsulosin on recurrent urinary tract infections in women with dysfunctional voiding. A total of 155 women with recurrent urinary tract infections and dysfunctional voiding were included and randomly assigned to the following groups: uroflowmetry biofeedback (group 1), α1-adrenoceptor antagonists (group 2), uroflowmetry biofeedback combined with α1-adrenoceptor antagonists (group 3) and no treatment (group 4). Patients were evaluated by the American Urological Association Symptom Index at 3, 6 and 12 months. Urodynamics was carried out in patients of groups 1, 2, and 3 at 3, 6 and 12 months, whereas urodynamics was only carried out at 12 months in group 4. All patients were followed up for 1 year with monthly urine cultures. The incidence of storage and emptying symptoms decreased significantly at 3, 6 and 12 months. Mean flow rate, flow time and voiding volume increased significantly (with a better outcome in patients of group 3), whereas post-void residual urine decreased. Mean opening detrusor pressure and detrusor pressure at maximum flow decreased significantly (with a better outcome in patients of group 3). Mean urethral closure pressure and maximum urethral closure pressure decreased significantly with a more significant decrease for patients in group 3. The prevalence of urinary tract infection decreased significantly in all groups after treatment, and this decrease remained stable during the follow up. In women with dysfunctional voiding and recurrent urinary tract infection, tamsulosin associated with uroflowmetry biofeedback might be an effective and safe treatment option for improving urinary symptoms and quality of life. © 2014 The Japanese Urological Association.

  9. Isolation, cloning and expression mapping of a gene encoding an anti-diuretic hormone and other CAPA-related peptides in the disease vector, Rhodnius prolixus

    USDA-ARS?s Scientific Manuscript database

    Following a blood meal, Rhodnius prolixus undergoes a rapid diuresis in order to eliminate excess water and salts. During the voiding of this primary urine, R. prolixus acts as a vector of Chagas’ disease, with the causative agent, Trypanosoma cruzi, infecting the human host via the urine. Diuresi...

  10. Development of a Voided Urine Assay for Detecting Prostate Cancer Noninvasively: A Pilot Study

    PubMed Central

    Trabulsi, Edouard J.; Tripathi, Sushil K.; Gomella, Leonard; Solomides, Charalambos; Wickstrom, Eric; Thakur, Mathew L.

    2017-01-01

    Objective To validate a hypothesis that prostate cancer (PCa) can be detected noninvasively by a simple and reliable assay by targeting genomic VPAC receptors expressed on malignant PCa cells shed in voided urine. Materials and Methods VPAC receptors were targeted with a specific biomolecule, TP4303, developed in our laboratory. With an IRB “exempt” approval of use of de-identified discarded samples, an aliquot of urine collected as a standard of care, from patients presenting to the urology clinic, (N=207, M= 176, F= 31, 21 years or older) was cytospun. The cells were fixed and treated with TP4303 and 4, 6 Dimidino-2-phenylindole, Dihydrochloride (DAPI). The cells were then observed under a microscope and cells with TP4303 orange fluorescence around the blue (DAPI) nucleus were considered malignant and those only with blue nucleus were regarded as normal. VPAC presence was validated using receptor blocking assay and cell malignancy was confirmed by PCa gene profile examination. Results The urine specimens were labeled only with gender and presenting diagnosis, with no personal health identifiers or other clinical data. The assay detected VPAC positive cells in 98.6% of the patients having a PCa diagnosis, (N=141), and none (0%) of the males with benign prostatic hyperplasia (BPH) (N=10). Of the 56 “normal” patients, 62.5% (N=35, M=10, F=25) were negative for VPAC cells; 19.6% (N=11, M=11, F=0) had VPAC positive cells; and 17.8% (N=10, M=4, F=6) were uninterpretable due to excessive crystals in the urine. Although data are limited, the sensitivity of the assay was 99.3% with confidence interval of 96.1%–100% and the specificity was 100% with confidence interval of 69.2%–100%. Receptor blocking assay and FACS analyses demonstrated the presence of VPAC receptors and gene profiling examinations confirmed that the cells expressing VPAC receptors were malignant PCa cells. Conclusion These preliminary data are highly encouraging and warrant further evaluation of the assay to serve as a simple and reliable tool to detect PCa noninvasively. PMID:28075510

  11. Bone Markers

    MedlinePlus

    ... Time and International Normalized Ratio (PT/INR) PSEN1 Quantitative Immunoglobulins Red Blood Cell (RBC) Antibody Identification Red ... void of urine. See More See Less Accordion Title Common Questions How is it used? One or ...

  12. Human and Methodological Sources of Variability in the Measurement of Urinary 8-Oxo-7,8-dihydro-2′-deoxyguanosine

    PubMed Central

    Møller, Peter; Henriksen, Trine; Mistry, Vilas; Koppen, Gudrun; Rossner, Pavel; Sram, Radim J.; Weimann, Allan; Poulsen, Henrik E.; Nataf, Robert; Andreoli, Roberta; Manini, Paola; Marczylo, Tim; Lam, Patricia; Evans, Mark D.; Kasai, Hiroshi; Kawai, Kazuaki; Li, Yun-Shan; Sakai, Kazuo; Singh, Rajinder; Teichert, Friederike; Farmer, Peter B.; Rozalski, Rafal; Gackowski, Daniel; Siomek, Agnieszka; Saez, Guillermo T.; Cerda, Concha; Broberg, Karin; Lindh, Christian; Hossain, Mohammad Bakhtiar; Haghdoost, Siamak; Hu, Chiung-Wen; Chao, Mu-Rong; Wu, Kuen-Yuh; Orhan, Hilmi; Senduran, Nilufer; Smith, Raymond J.; Santella, Regina M.; Su, Yali; Cortez, Czarina; Yeh, Susan; Olinski, Ryszard; Loft, Steffen

    2013-01-01

    Abstract Aims: Urinary 8-oxo-7,8-dihydro-2′-deoxyguanosine (8-oxodG) is a widely used biomarker of oxidative stress. However, variability between chromatographic and ELISA methods hampers interpretation of data, and this variability may increase should urine composition differ between individuals, leading to assay interference. Furthermore, optimal urine sampling conditions are not well defined. We performed inter-laboratory comparisons of 8-oxodG measurement between mass spectrometric-, electrochemical- and ELISA-based methods, using common within-technique calibrants to analyze 8-oxodG-spiked phosphate-buffered saline and urine samples. We also investigated human subject- and sample collection-related variables, as potential sources of variability. Results: Chromatographic assays showed high agreement across urines from different subjects, whereas ELISAs showed far more inter-laboratory variation and generally overestimated levels, compared to the chromatographic assays. Excretion rates in timed ‘spot’ samples showed strong correlations with 24 h excretion (the ‘gold’ standard) of urinary 8-oxodG (rp 0.67–0.90), although the associations were weaker for 8-oxodG adjusted for creatinine or specific gravity (SG). The within-individual excretion of 8-oxodG varied only moderately between days (CV 17% for 24 h excretion and 20% for first void, creatinine-corrected samples). Innovation: This is the first comprehensive study of both human and methodological factors influencing 8-oxodG measurement, providing key information for future studies with this important biomarker. Conclusion: ELISA variability is greater than chromatographic assay variability, and cannot determine absolute levels of 8-oxodG. Use of standardized calibrants greatly improves intra-technique agreement and, for the chromatographic assays, importantly allows integration of results for pooled analyses. If 24 h samples are not feasible, creatinine- or SG-adjusted first morning samples are recommended. Antioxid. Redox Signal. 18, 2377–2391. PMID:23198723

  13. PCR for diagnosis of male Trichomonas vaginalis infection with chronic prostatitis and urethritis.

    PubMed

    Lee, Jong Jin; Moon, Hong Sang; Lee, Tchun Yong; Hwang, Hwan Sik; Ahn, Myoung-Hee; Ryu, Jae-Sook

    2012-06-01

    The aim of this study was to assess the usefulness of PCR for diagnosis of Trichomonas vaginalis infection among male patients with chronic recurrent prostatitis and urethritis. Between June 2001 and December 2003, a total of 33 patients visited the Department of Urology, Hanyang University Guri Hospital and were examined for T. vaginalis infection by PCR and culture in TYM medium. For the PCR, we used primers based on a repetitive sequence cloned from T. vaginalis (TV-E650). Voided bladder urine (VB1 and VB3) was sampled from 33 men with symptoms of lower urinary tract infection (urethral charge, residual urine sensation, and frequency). Culture failed to detect any T. vaginalis infection whereas PCR identified 7 cases of trichomoniasis (21.2%). Five of the 7 cases had been diagnosed with prostatitis and 2 with urethritis. PCR for the 5 prostatitis cases yielded a positive 330 bp band from bothVB1 and VB3, whereas positive results were only obtained from VB1 for the 2 urethritis patients. We showed that the PCR method could detect T. vaginalis when there was only 1 T. vaginalis cell per PCR mixture. Our results strongly support the usefulness of PCR on urine samples for detecting T. vaginalis in chronic prostatitis and urethritis patients.

  14. Urinary retention and post-void residual urine in men: separating truth from tradition.

    PubMed

    Kaplan, Steven A; Wein, Alan J; Staskin, David R; Roehrborn, Claus G; Steers, William D

    2008-07-01

    The definitions of acute and chronic urinary retention remain empirical and subject to wide interpretation. Standardized criteria have not been established and many questions remain unanswered. Moreover, the definition of significant post-void residual urine is unclear. We reviewed several aspects of urinary retention that require clarification with the objective of stimulating discussion among urologists to establish an accurate and coherent definition of urinary retention and significant post-void residual urine, and clarify risk factors. A MEDLINE search for articles written in English and published before April 2007 was done using a list of terms related to urinary retention. Articles not directly relevant to urinary retention or post-void residual urine were excluded. The term urinary retention lacks precise clinical or urodynamic meaning. Use of this term to describe a symptom, a sign, and a condition further complicates the issue. Many factors can contribute to the development of retention, including bladder outlet obstruction, detrusor underactivity, and neurogenic bladder conditions. Community based studies and clinical trials in patients with benign prostatic enlargement and/or lower urinary tract symptoms yield different estimates of the incidence of retention and only provide information on the epidemiology of acute urinary retention. However, age, previous retention episodes, lower urinary tract symptoms, chronic inflammation, serum prostate specific antigen level, prostate size, and urodynamic variables appear to be predictors of acute urinary retention. Alpha-receptor antagonists and 5alpha-reductase inhibitors may be useful in preventing urinary retention episodes and progressive benign prostatic enlargement. Clinical trials on the short-term use of antimuscarinics have not provided evidence that these agents increase the risk of retention; data on longer term administration are needed. Clinicians are adopting less invasive approaches (eg pharmacology or catheterization) to treating patients who present with the symptoms, sign, and condition of urinary retention. Faced with an abundance of new data on acute urinary retention, urologists need to reach a consensus about the risks of urinary retention; this may promote movement toward patient centered prevention strategies with tailored treatment options.

  15. Can Physical Exercise or Food Deprivation Cause Release of Fat-Stored Cannabinoids?

    PubMed Central

    Westin, Andreas Austgulen; Mjønes, George; Burchardt, Ola; Fuskevåg, Ole Martin; Slørdal, Lars

    2014-01-01

    The aim of this study was to evaluate whether physical exercise or food deprivation may increase cannabinoid levels in serum or urine in abstinent chronic cannabis users. The study took place in a drug detoxification ward parallel to study participants receiving treatment. Six chronic, daily cannabis users (one female, five males, average age 30.0 years; BMI 20.8) were exposed to a 45-min. moderate-intensity workout and a 24-hr period of food deprivation. Serum samples were drawn prior to and after interventions and analysed for Δ9-tetrahydrocannabinol (THC) and 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THCCOOH) by liquid chromatography–tandem mass spectrometry (LCMSMS), and all voided urine was tested for THCCOOH by LCMSMS and normalized to the creatinine levels, yielding ng/mg ratios. There were no major differences in the measured cannabinoid levels in serum or urine before and after physical exercise or food deprivation. We conclude that exercise and/or food deprivation are unlikely to cause sufficient cannabinoid concentration changes to hamper correct interpretations in drug testing programmes. PMID:24674455

  16. Cytologic Features of Renal Carcinoma Associated with Xp11.2 Translocations/ TFE3 Gene Fusions: A Case Report with Voided and Catheterized Urine Cytology and a Literature Review.

    PubMed

    Kuwamoto, Satoshi; Murai, Yuki; Endo, Yukari; Masago, Toshihiko; Kuroda, Naoto; Horie, Yasushi

    2014-01-01

    Renal carcinomas associated with Xp11.2 translocations/TFE3 gene fusions are rare subtypes of renal neoplasm that predominantly occur in younger individuals. There are very few reports describing the cytologic features of these tumors. A 27-year-old man presented with hematuria and was found to have a mass in the lower part of the right kidney. Cytology of catheterized urine obtained from the right renal pelvis showed clusters of cells with abundant clear or eosinophilic granular cytoplasm, large round nuclei and prominent nucleoli. Papillary clusters containing thin fibrous stroma were occasionally seen. Voided urine cytology showed similar cell clusters but degeneration made the features obscure. Nephroureterectomy revealed a renal tumor showing a mixed papillary and nested architecture. The diagnosis was confirmed by immunohistochemistry and fluorescence in situ hybridization. The present case indicates that the characteristic features of these tumor subtypes can be retained in urine cytology. Cytology may be enough to suspect these tumors as part of the differential diagnosis when the patient's age and imaging findings are taken into account and may facilitate further studies for a definitive diagnosis. © 2014 S. Karger AG, Basel.

  17. Clinical presentation of urinary tract infection (UTI) differs with aging in women.

    PubMed

    Arinzon, Zeev; Shabat, Shay; Peisakh, Alexander; Berner, Yitshal

    2012-01-01

    Uncomplicated UTI is among the most common health problems seen in general practice and typically affects immunocompetent, anatomically normal women. The aim of this study was to explore the difference in clinical presentation in acute, uncomplicated UTI in otherwise healthy community dwelling, premenopausal (Pre-M) and postmenopausal (Post-M) women. A UTI was defined as uropathogen of more than 10(3)cfu/ml in midstream urine culture. Symptoms of UTI were divided to three: during voiding, local symptoms, and generalized symptoms. A total of 196 women aged a minimum of 45 years with diagnosis of UTI were studied. The patients were divided into two groups: Pre-M (n=102, mean age 48.14 years) and Post-M (n=94, mean age 69.21 years). The predominant complaints in Pre-M women were local symptoms. The clinical presentations showed more severity in the Post-M group than in Pre-M women, predominantly generalized unspecific symptoms and storage symptoms. Advanced age positively correlated with urgency of urination, painful voiding, urinary incontinence, sexual activity, low-back pain, lower abdominal pain and negatively correlated with frequency, painful and burning of urination and bladder pain. Our study showed that clinical presentation of UTI in Pre-M and Post-M women is different. The differences are presented not only by the voiding itself and by local symptoms but also by unspecified generalized symptoms that is especially important in elderly patients. Copyright © 2011. Published by Elsevier Ireland Ltd.

  18. Comparison between uroflowmetry and sonouroflowmetry in recording of urinary flow in healthy men.

    PubMed

    Krhut, Jan; Gärtner, Marcel; Sýkora, Radek; Hurtík, Petr; Burda, Michal; Luňáček, Libor; Zvarová, Katarína; Zvara, Peter

    2015-08-01

    To evaluate the accuracy of sonouroflowmetry in recording urinary flow parameters and voided volume. A total of 25 healthy male volunteers (age 18-63 years) were included in the study. All participants were asked to carry out uroflowmetry synchronous with recording of the sound generated by the urine stream hitting the water level in the urine collection receptacle, using a dedicated cell phone. From 188 recordings, 34 were excluded, because of voided volume <150 mL or technical problems during recording. Sonouroflowmetry recording was visualized in a form of a trace, representing sound intensity over time. Subsequently, the matching datasets of uroflowmetry and sonouroflowmetry were compared with respect to flow time, voided volume, maximum flow rate and average flow rate. Pearson's correlation coefficient was used to compare parameters recorded by uroflowmetry with those calculated based on sonouroflowmetry recordings. The flow pattern recorded by sonouroflowmetry showed a good correlation with the uroflowmetry trace. A strong correlation (Pearson's correlation coefficient 0.87) was documented between uroflowmetry-recorded flow time and duration of the sound signal recorded with sonouroflowmetry. A moderate correlation was observed in voided volume (Pearson's correlation coefficient 0.68) and average flow rate (Pearson's correlation coefficient 0.57). A weak correlation (Pearson's correlation coefficient 0.38) between maximum flow rate recorded using uroflowmetry and sonouroflowmetry-recorded peak sound intensity was documented. The present study shows that the basic concept utilizing sound analysis for estimation of urinary flow parameters and voided volume is valid. However, further development of this technology and standardization of recording algorithm are required. © 2015 The Japanese Urological Association.

  19. Pharmacodynamic evaluation of Lys5, MeLeu9, Nle10-NKA(4–10) prokinetic effects on bladder and colon activity in acute spinal cord transected and spinally intact rats

    PubMed Central

    Kullmann, F. Aura; Katofiasc, M.; Thor, K.B.; Marson, L.

    2017-01-01

    Purpose To determine feasibility of a novel therapeutic approach to drug-induced voiding after spinal cord injury (SCI) using a well-characterized, peptide, neurokinin 2 receptor (NK2 receptor) agonist, Lys5, MeLeu9, Nle10-NKA(4–10) (LMN-NKA). Methods Cystometry and colorectal pressure measurements were performed in urethane anesthetized, intact and acutely spinalized, female rats. Bladder pressure and voiding were monitored in response to intravenous LMN-NKA given with the bladder filled to 70% capacity. Results LMN-NKA (0.1–300 µg/kg) produced dose dependent, rapid (< 60 s), short duration (< 15 min) increases in bladder pressure. In intact rats, doses above 0.3–1 µg/kg induced urine release (voiding efficiency of ~ 70% at ≥ 1 µg/kg). In spinalized rats, urine release required higher doses (≥ 10 µg/kg) and was less efficient (30–50%). LMN-NKA (0.1–100 µg/kg) also produced dose dependent increases in colorectal pressure. No tachyphylaxis was observed, and the responses were blocked by an NK2 receptor antagonist (GR159897, 1 mg/kg i.v.). No obvious cardiorespiratory effects were noted. Conclusions These results suggest that rapid-onset, short duration, drug-induced voiding is possible in acute spinal and intact rats with intravenous administration of an NK2 receptor agonist. Future challenges remain in regards to finding alternative routes of administration that produce clinically significant voiding, multiple times per day, in animal models of chronic SCI. PMID:27889808

  20. Prevalence and characteristics of voiding difficulties in women: are subjective symptoms substantiated by objective urodynamic data?

    PubMed

    Groutz, A; Gordon, D; Lessing, J B; Wolman, I; Jaffa, A; David, M P

    1999-08-01

    To examine the prevalence and characteristics of voiding difficulties in women. Two hundred six consecutive female patients who attended a urogynecology clinic were recruited. Patients were interviewed regarding the presence and severity of symptoms that would suggest voiding difficulties (ie, hesitancy, straining to void, weak or prolonged stream, intermittent stream, double voiding, incomplete emptying, reduction, and positional changes to start or complete voiding). Urodynamic evidence of voiding difficulty was considered as a peak flow rate less than 12 mL/s (voided volume greater than 100 mL), or residual urine volume greater than 150 mL, on two or more readings. Residual urinary volume, flow patterns, and pressure-flow parameters were analyzed and compared between symptomatic and asymptomatic patients who had urodynamic parameters of voiding difficulties. One hundred twenty-seven (61.7%) women reported having voiding difficulty symptoms; 79 others (38.3%) were free of such symptoms. Urodynamic diagnosis of voiding difficulty was made in 40 women (19.4% of the study population): 27 in the symptomatic group and 13 in the asymptomatic group (21.2% and 16.5%, respectively). Only 1 patient had voiding difficulty due to bladder outlet obstruction. All other cases of low flow rate were due to impaired detrusor contractility. Objective evidence of voiding difficulty may be found in both symptomatic and asymptomatic patients and is usually due to impaired detrusor contractility. The clinical significance of the abnormal flow parameters in asymptomatic patients is unclear.

  1. Perturbations in the Urinary Exosome in Transplant Rejection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sigdel, Tara K.; NG, Yolanda; Lee, Sangho

    Background: Urine exosomes, vesicles exocytosed into urine by all renal epithelial cell types, occur under normal physiologic and disease states. Exosome contents may mirror disease-specific proteome perturbations in kidney injury. Analysis methodologies for the exosomal fraction of the urinary proteome were developed and for comparing the urinary exosomal fraction versus unfractionated proteome for biomarker discovery. Methods: Urine exosomes were isolated by centrifugal filtration from mid-stream, second morning void, urine samples collected from kidney transplant recipients with and without biopsy matched acute rejection. The proteomes of unfractionated whole urine (Uw) and urine exosomes (Uexo) underwent mass spectrometry-based quantitative proteomics analysis. Themore » proteome data were analyzed for significant differential protein abundances in acute rejection (AR). Results: Identifications of 1018 and 349 proteins, Uw and Uexo fractions, respectively, demonstrated a 279 protein overlap between the two urinary compartments with 25%(70) of overlapping proteins unique to Uexoand represented membrane bound proteins (p=9.31e-7). Of 349 urine exosomal proteins identified in transplant patients 220 were not previously identified in the normal urine exosomal fraction. Uexo proteins (11), functioning in the inflammatory / stress response, were more abundant in patients with biopsy-confirmed acute rejection, 3 of which were exclusive to Uexo. Uexo AR-specific biomarkers (8) were also detected in Uw, but since they were observed at significantly lower abundances in Uw, they were not significant for AR in Uw. Conclusions: A rapid urinary exosome isolation method and quantitative measurement of enriched Uexo proteins was applied. Urine proteins specific to the exosomal fraction were detected either in unfractionated urine (at low abundances) or by Uexo fraction analysis. Perturbed proteins in the exosomal compartment of urine collected from kidney transplant patients were specific to inflammatory responses, and were not observed in the Uexo fraction from normal healthy subjects. Uexo specific protein alterations in renal disease provide potential mechanistic insights and offer a unique panel of sensitive biomarkers for monitoring for acute transplant rejection.« less

  2. Glyphosate in Irish adults - A pilot study in 2017.

    PubMed

    Connolly, Alison; Leahy, Michelle; Jones, Kate; Kenny, Laura; Coggins, Marie A

    2018-08-01

    Glyphosate is the highest volume herbicide used globally and has recently been classified as a 2 A 'probably carcinogenic to humans' by the International Agency for Research on Cancer (IARC). There is limited data to evaluate the public health impacts from glyphosate exposure. The objective of this study is to conduct an exploratory glyphosate exposure assessment study among Irish adults, who were non-occupational users of glyphosate. A convenient sampling method was used, collecting one first morning void spot urine sample from each participant. A biomonitoring survey involving the collection and analysis of 20 ml spot urine samples from 50 Irish adults was conducted in June 2017. Participants completed a short questionnaire to collect information on demographics, dietary habits and lifestyle. Glyphosate was extracted using solid phase extraction (SPE) and analysed by liquid chromatography tandem mass spectrometry (LC-MC/MS). Of the 50 urine samples analysed, 10 (20%) contained detectable levels of glyphosate (0.80-1.35 µg L -1 ). Exposure concentrations are higher than those reported in comparable studies of European and American adults. Glyphosate was detectable in 20% of the samples collected from Irish adults. The low proportion of detectable glyphosate levels could be due to lower localised use of pesticides, having a small sample size or the higher analytical detection limit used in this study (0.5 µg L -1 ), which could underestimate the true exposure and warrants further investigation. Given the widespread use of glyphosate, further information on population exposure is required to advance our understanding of the relationship between chronic low dose exposure to glyphosate and human health risk. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Urine cell-based DNA methylation classifier for monitoring bladder cancer.

    PubMed

    van der Heijden, Antoine G; Mengual, Lourdes; Ingelmo-Torres, Mercedes; Lozano, Juan J; van Rijt-van de Westerlo, Cindy C M; Baixauli, Montserrat; Geavlete, Bogdan; Moldoveanud, Cristian; Ene, Cosmin; Dinney, Colin P; Czerniak, Bogdan; Schalken, Jack A; Kiemeney, Lambertus A L M; Ribal, Maria J; Witjes, J Alfred; Alcaraz, Antonio

    2018-01-01

    Current standard methods used to detect and monitor bladder cancer (BC) are invasive or have low sensitivity. This study aimed to develop a urine methylation biomarker classifier for BC monitoring and validate this classifier in patients in follow-up for bladder cancer (PFBC). Voided urine samples ( N  = 725) from BC patients, controls, and PFBC were prospectively collected in four centers. Finally, 626 urine samples were available for analysis. DNA was extracted from the urinary cells and bisulfite modificated, and methylation status was analyzed using pyrosequencing. Cytology was available from a subset of patients ( N  = 399). In the discovery phase, seven selected genes from the literature ( CDH13 , CFTR , NID2 , SALL3 , TMEFF2 , TWIST1 , and VIM2 ) were studied in 111 BC and 57 control samples. This training set was used to develop a gene classifier by logistic regression and was validated in 458 PFBC samples (173 with recurrence). A three-gene methylation classifier containing CFTR , SALL3 , and TWIST1 was developed in the training set (AUC 0.874). The classifier achieved an AUC of 0.741 in the validation series. Cytology results were available for 308 samples from the validation set. Cytology achieved AUC 0.696 whereas the classifier in this subset of patients reached an AUC 0.768. Combining the methylation classifier with cytology results achieved an AUC 0.86 in the validation set, with a sensitivity of 96%, a specificity of 40%, and a positive and negative predictive value of 56 and 92%, respectively. The combination of the three-gene methylation classifier and cytology results has high sensitivity and high negative predictive value in a real clinical scenario (PFBC). The proposed classifier is a useful test for predicting BC recurrence and decrease the number of cystoscopies in the follow-up of BC patients. If only patients with a positive combined classifier result would be cystoscopied, 36% of all cystoscopies can be prevented.

  4. Voiding and sexual dysfunctions after pelvic fracture urethral injuries treated with either initial cystostomy and delayed urethroplasty or immediate primary urethral realignment.

    PubMed

    Aşci, R; Sarikaya, S; Büyükalpelli, R; Saylik, A; Yilmaz, A F; Yildiz, S

    1999-08-01

    The aim of this study is to evaluate the effects of the different immediate treatment modalities on the sexual and voiding functions in pelvic fracture urethral injuries. The records of 38 male patients with traumatic posterior urethral injuries were reviewed, 18 of whom were treated by initial suprapubic cystostomy and delayed repair (Group 1), and 20 by primary urethral realignment (Group 2). Types of pelvic fractures and urethral injuries were classified according to surgical and radiological findings. Long-term voiding functions were determined by the patient questionnaire, residual urine and uroflow. Sexual functions were also determined by the patient questionnaire and a penile duplex ultrasound study. Mean follow-ups of Groups 1 and 2 were 37 and 39 months, respectively. Membranous urethral disruption extending to the urogenital diaphragm was the most frequent urethral injury (type 3), with incidences of 66.7% and 77.7%, respectively. There were no statistically significant differences in mean age, incidence of pelvic fracture types and urethral injury types between groups (p > 0.05). After the immediate treatments, 16.7% and 55% of the patients regained normal urination, and stricture developed in 83.3% and 45% of the patients, respectively. In 44.4% of the patients in Group 1 and 10% in Group 2, urethral strictures required open urethroplasty (p < 0.05). Erectile impotence before urethroplasty in 17.6% and 20%, anejaculation after urethroplasty in 17.6% and 15% and incontinence in 5.6% and 10% of the patients were found in Groups 1 and 2, respectively (p > 0.05). However, 88.8% and 90% of patients eventually achieved normal urination with complete continence. Sexual and voiding dysfunction after pelvic fracture posterior urethral injury seem to be the result of the injury itself, not of the immediate treatment modalities. In urethral disruption injuries, primary urethral realignment seems more favourable than suprapubic cystostomy and delayed repair.

  5. A metabolomics approach to the identification of biomarkers of sugar-sweetened beverage intake.

    PubMed

    Gibbons, Helena; McNulty, Breige A; Nugent, Anne P; Walton, Janette; Flynn, Albert; Gibney, Michael J; Brennan, Lorraine

    2015-03-01

    The association between sugar-sweetened beverages (SSBs) and health risks remains controversial. To clarify proposed links, reliable and accurate dietary assessment methods of food intakes are essential. The aim of this present work was to use a metabolomics approach to identify a panel of urinary biomarkers indicative of SSB consumption from a national food consumption survey and subsequently validate this panel in an acute intervention study. Heat map analysis was performed to identify correlations between ¹H nuclear magnetic resonance (NMR) spectral regions and SSB intakes in participants of the National Adult Nutrition Survey (n = 565). Metabolites were identified and receiver operating characteristic (ROC) analysis was performed to assess sensitivity and specificity of biomarkers. The panel of biomarkers was validated in an acute study (n = 10). A fasting first-void urine sample and postprandial samples (2, 4, 6 h) were collected after SSB consumption. After NMR spectroscopic profiling of the urine samples, multivariate data analysis was applied. A panel of 4 biomarkers-formate, citrulline, taurine, and isocitrate-were identified as markers of SSB intake. This panel of biomarkers had an area under the curve of 0.8 for ROC analysis and a sensitivity and specificity of 0.7 and 0.8, respectively. All 4 biomarkers were identified in the SSB sample. After acute consumption of an SSB drink, all 4 metabolites increased in the urine. The present metabolomics-based strategy proved to be successful in the identification of SSB biomarkers. Future work will ascertain how to translate this panel of markers for use in nutrition epidemiology. © 2015 American Society for Nutrition.

  6. Towards nonionizing photoacoustic cystography

    NASA Astrophysics Data System (ADS)

    Kim, Chulhong; Jeon, Mansik; Wang, Lihong V.

    2012-02-01

    Normally, urine flows down from kidneys to bladders. Vesicoureteral reflux (VUR) is the abnormal flow of urine from bladders back to kidneys. VUR commonly follows urinary tract infection and leads to renal infection. Fluoroscopic voiding cystourethrography and direct radionuclide voiding cystography have been clinical gold standards for VUR imaging, but these methods are ionizing. Here, we demonstrate the feasibility of a novel and nonionizing process for VUR mapping in vivo, called photoacoustic cystography (PAC). Using a photoacoustic (PA) imaging system, we have successfully imaged a rat bladder filled with clinically being used methylene blue dye. An image contrast of ~8 was achieved. Further, spectroscopic PAC confirmed the accumulation of methylene blue in the bladder. Using a laser pulse energy of less than 1 mJ/cm2, bladder was clearly visible in the PA image. Our results suggest that this technology would be a useful clinical tool, allowing clinicians to identify bladder noninvasively in vivo.

  7. Risk factors of urinary tract infection in pregnancy.

    PubMed

    Haider, Gulfareen; Zehra, Nishat; Munir, Aftab Afroze; Haider, Ambreen

    2010-03-01

    To determine the frequency, risk factors and pattern of urinary complaints during pregnancy. A descriptive study was conducted in the Obstetric and Gynaecology Department of Isra University Hospital, Hyderabad from 1st January to 30th August 2008. Total 232 women were selected to ascertain the frequency and pattern of urinary symptoms as well as the risk factors of urinary tract infection (UTI) such as age, parity, education, past history of UTI and haemoglobin among women attending an antenatal clinic. All pregnant women irrespective of age, parity and gestational age were included, while women with known underlying renal pathology, chronic renal disease, renal transplant, diabetes or taking immunosuppressant therapy were excluded. Informed consent was taken and data collected on a self designed proforma. All the women underwent complete examination of urine. Dipstick test was performed on midstream urine and urine was cultured incase of positive dipstick test and women with urinary symptoms. Data was analyzed on SPSS version 11. Odds ratio and 95% confidence interval were calculated among the categorical parameters by applying the Fisher's exact test. Out of 232 women, 108(46.5%) reported urinary symptoms which were due to pregnancy induced changes on urinary system as no growth was obtained on urine culture, while 10 (4.3%) were due to underlying UTI. Most common urinary symptom in these women was abnormal voiding pattern 85 (40.3%) followed by irritative symptoms and voiding difficulties. Illiteracy, history of sexual activity, low socioeconomic (monthly income < Rs. 10,000 / month) group, past history of UTI and multiparity were found to be risk factors for UTI in these women. On complete urine examination, 222 (95.6%) patients either did not reveal any pus cells or had less than 5 WBC/HPF. Out of 108 cultures, only 10 (4.3%) specimens showed growth. E-coli was the most commonly detected organism 7 (3%) followed by S-aureus in 3 (1.3%). The common urinary symptoms encountered in the studied women were abnormal voiding pattern followed by irritative symptoms. Majority of urinary symptoms were due to pregnancy related changes in the urinary system. Past history of UTI, sexual activity, lower socioeconomic group and multi parity were significant risk factors for UTI.

  8. Changes in voiding behavior in a mouse model of Alzheimer’s disease

    PubMed Central

    Biallosterski, B. T.; Prickaerts, J.; Rahnama’i, M. S.; de Wachter, S.; van Koeveringe, G. A.; Meriaux, C.

    2015-01-01

    Besides cognitive decline and behavioral alteration, urinary incontinence often occurs in patients suffering from Alzheimer’s disease (AD). To determine whether the transgenic mouse model of AD, APP/PS1 (APPSL/PS1M146L) mouse, shows alteration of the urinary bladder function and anxiety, as for patients with AD, we examined the urinary marking behavior in relation to affective behavior. At 18 months of age voiding behavior of APP/PS1 and wild type (WT) mice was assessed by using a modified filter paper assay in combination with video tracing, with the cage divided into a center and corner zones. Anxiety-related behavior and locomotion were respectively tested in an elevated zero maze (EZM) and an open field (OF). The APP/PS1 mice urinated more in the center zone than the WT mice. The total volume of markings was significantly lower in the APP/PS1 mice. In both groups, the average volume of a marking in the corner zone was larger than in the center zone. In the EZM, the APP/PS1 mice spent less time in the open arms of the arena, considered as anxiogenic zones, than the WT mice. During the OF task, the APP/PS1 mice covered a longer distance than the WT mice. These findings show that the APP/PS1 mice have a different voiding behavior compared to the WT mice, i.e., urinating with small volumes and voiding in the center of the cage, and suggest that increased locomotor activity and anxiety-related behaviors are factors in the change in voiding pattern in the APP/PS1 mouse. PMID:26379542

  9. [Advances in clinical study of nocturia].

    PubMed

    Guan, Zhi-chen

    2010-08-18

    Nocturia is one of the most common reasons for interrupted sleep in general adult population. The condition affects both men and women, with an incidence that increases dramatically with age. Nocturia has a negative impact on quality of life, affecting both morbidity and mortality. International Continence Society (ICS) issued a report of terminology standardization in 2002, in which nocturia is defined as waking during the night at least once to urinate. Nocturia is a common complaint in elderly population. Although most cases of nocturia are assumed to be caused by urologic problems, the interacting effects of aging and sleep on renal and urinary function, in fact, cause nocturia in the elderly. Effective diagnosis of the condition is dependent on a clear understanding of its underlying etiology. Multiple factors may cause nocturia, such as behavioral or environmental factors and pathologic conditions. In general, the causes of nocturia fall into three categories: diurnal polyuria, nocturnal polyuria, and low bladder capacity. Careful evaluation of medications and underlying medical conditions is essential for the proper management of nocturia. A voiding diary is necessary to diagnose the syndrome of nocturnal polyuria, which is a common cause of nocturia. Addressing any underlying conditions that contribute to nocturia is the first step in treating the condition. Lifestyle and behavioral changes may provide benefit in some individuals, but for many cases, pharmacotherapy is the best option. Antimuscarinic agents are first-line therapies for overactive bladder and are often used in the management of nocturia. Current treatment options also include desmopressin, a synthetic analog of arginine vasopressin, which can increase urinary osmolality and decrease total urinary volume. The desmopressin therefore increases the length of time until the first nocturnal void and decreases the number of nocturnal voids, the NUV voided, and the percentage of urine voided at night.

  10. Applying the Paris System for Reporting Urine Cytology Increases the Rate of Atypical Urothelial Cells in Benign Cases: A Need for Patient Management Recommendations.

    PubMed

    Granados, Rosario; Duarte, Joanny A; Corrales, Teresa; Camarmo, Encarnación; Bajo, Paloma

    2017-01-01

    The Paris System (TPS) for reporting urinary cytology attempts to unify the terminology in this field. To analyze the impact of adopting TPS by measuring nomenclature agreement and cytohistological correlation. Voided urine liquid-based cytology samples corresponding to 149 biopsy-proven cases (76 high-grade carcinomas, 40 low-grade carcinomas, and 33 benign lesions), were reclassified by the same pathologist using TPS. Diagnostic agreement and sensitivity for both nomenclature systems was measured. When using TPS, the rate of atypical samples increased 8 times (from 3 to 24.2%) in benign cases, 10 times (from 2.5 to 25%) in low-grade carcinomas, and 2.4 times (from 6.6 to 15.8%) in high-grade carcinomas. The false-positive rate (abnormal cytology in negative or low-grade carcinoma cases) increased from 11 to 34.2%. Sensitivity was higher (63 vs. 49%) with TPS at the expense of a lower specificity (73 vs. 91%). The agreement between both nomenclatures was moderate for negative and high-grade carcinoma cases (k = 0.42 and 0.56, respectively) and weak for low-grade tumors (k = 0.35). Adopting TPS for reporting urine cytology results in a considerable increase in atypical diagnoses, improving sensitivity but lowering specificity. Appropriate management recommendations for patients with an atypical cytological diagnosis are required. © 2016 S. Karger AG, Basel.

  11. Changes in urination according to the sound of running water using a mobile phone application.

    PubMed

    Kwon, Whi-An; Kim, Sung Han; Kim, Sohee; Joung, Jae Young; Chung, Jinsoo; Lee, Kang Hyun; Lee, Sang-Jin; Seo, Ho Kyung

    2015-01-01

    The sound of running water (SRW) has been effectively used for toilet training during toddlerhood. However, the effect of SRW on voiding functions in adult males with lower urinary tract symptoms (LUTS) has not been evaluated. To determine the effect of SRW on urination in male patients with LUTS, multiple voiding parameters of uroflowmetry with postvoid residual urine (PVR) were assessed according to the presence of SRW played by a mobile application. Eighteen consecutive male patients with LUTS were prospectively enrolled between March and April 2014. Uroflowmetry with PVR measured by a bladder scan was randomly performed once weekly for two consecutive weeks with and without SRW in a completely sealed room after pre-checked bladder volume was scanned to be more than 150 cc. SRW was played with river water sounds amongst relaxed melodies from a smartphone mobile application. The mean age of enrolled patients and their mean International Prostate Symptom Score (IPSS) were 58.9 ± 7.7 years (range: 46-70) and 13.1 ± 5.9, respectively. All patients had not been prescribed any medications, including alpha-blockers or anti-muscarinic agents, in the last 3 months. There was a significant increase in mean peak flow rate (PFR) with SRW in comparison to without SRW (15.7 mL/s vs. 12.3 mL/s, respectively, p = 0.0125). However, there were no differences in other uroflowmetric parameters, including PVR. The study showed that SRW from a mobile phone application may be helpful in facilitating voiding functions by increasing PFR in male LUTS patients.

  12. Women's toileting behaviour related to urinary elimination: concept analysis.

    PubMed

    Wang, Kefang; Palmer, Mary H

    2010-08-01

    This paper is a report of analysis of the concept of women's toileting behaviour related to urinary elimination. Behaviours related to emptying urine from the bladder can contribute to bladder health problems. Evidence exists that clinical interventions focusing on specific behaviours that promote urine storage and controlled emptying are effective in reducing lower urinary tract symptoms. The concept of women's toileting behaviour related to urinary elimination has not been well-developed to guide nursing research and intervention. The CINAHL, Medline, PsycInfo and ISI Citation databases were searched for publications between January, 1960 and May, 2009, using combinations of keywords related to women's toileting behaviour. Additional publications were identified by examining the reference lists in the papers identified. Johnson's behavioural system model provided the conceptual framework to identify the concept. Walker and Avant's method was used for this concept analysis. Women's toileting behaviour related to urinary elimination can be defined as voluntary actions related to the physiological event of emptying the bladder, which is comprised of specific attributes including voiding place, voiding time, voiding position and voiding style. This behaviour is also influenced by the physical and social environments. An explicit definition of women's toileting behaviour can offer a basis for nurses to understand the factors involved in women's toileting behaviour. It also facilitates the development of an instrument to assess women's toileting behaviour better, and to facilitate development of behavioural interventions designed to prevent, eliminate, reduce and manage female lower urinary tract symptoms.

  13. Urinary and breast milk biomarkers to assess exposure to naphthalene in pregnant women: an investigation of personal and indoor air sources

    PubMed Central

    2014-01-01

    Background Naphthalene exposures for most non-occupationally exposed individuals occur primarily indoors at home. Residential indoor sources include pest control products (specifically moth balls), incomplete combustion such as cigarette smoke, woodstoves and cooking, some consumer and building products, and emissions from gasoline sources found in attached garages. The study aim was to assess naphthalene exposure in pregnant women from Canada, using air measurements and biomarkers of exposure. Methods Pregnant women residing in Ottawa, Ontario completed personal and indoor air sampling, and questionnaires. During pregnancy, pooled urine voids were collected over two 24-hour periods on a weekday and a weekend day. At 2–3 months post-birth, they provided a spot urine sample and a breast milk sample following the 24-hour air monitoring. Urines were analyzed for 1-naphthol and 2-naphthol and breast milk for naphthalene. Simple linear regression models examined associations between known naphthalene sources, air and biomarker samples. Results Study recruitment rate was 11.2% resulting in 80 eligible women being included. Weekday and weekend samples were highly correlated for both personal (r = 0.83, p < 0.0001) and indoor air naphthalene (r = 0.91, p < 0.0001). Urine specific gravity (SG)-adjusted 2-naphthol concentrations collected on weekdays and weekends (r = 0.78, p < 0.001), and between pregnancy and postpartum samples (r = 0.54, p < 0.001) were correlated. Indoor and personal air naphthalene concentrations were significantly higher post-birth than during pregnancy (p < 0.0001 for signed rank tests); concurrent urine samples were not significantly different. Naphthalene in breast milk was associated with urinary 1-naphthol: a 10% increase in 1-naphthol was associated with a 1.6% increase in breast milk naphthalene (95% CI: 0.2%-3.1%). No significant associations were observed between naphthalene sources reported in self-administered questionnaires and the air or biomarker concentrations. Conclusions Median urinary concentrations of naphthalene metabolites tended to be similar to (1-naphthol) or lower (2-naphthol) than those reported in a Canadian survey of women of reproductive age. Only urinary 1-naphthol and naphthalene in breast milk were associated. Potential reasons for the lack of other associations include a lack of sources, varying biotransformation rates and behavioural differences over time. PMID:24767676

  14. Cluster analysis identifies three urodynamic patterns in patients with orthotopic neobladder reconstruction.

    PubMed

    Kim, Kwang Hyun; Yoon, Hyun Suk; Song, Wan; Choo, Hee Jung; Yoon, Hana; Chung, Woo Sik; Sim, Bong Suk; Lee, Dong Hyeon

    2017-01-01

    To classify patients with orthotopic neobladder based on urodynamic parameters using cluster analysis and to characterize the voiding function of each group. From January 2012 to November 2015, 142 patients with bladder cancer underwent radical cystectomy and Studer neobladder reconstruction at our institute. Of the 142 patients, 103 with complete urodynamic data and information on urinary functional outcomes were included in this study. K-means clustering was performed with urodynamic parameters which included maximal cystometric capacity, residual volume, maximal flow rate, compliance, and detrusor pressure at maximum flow rate. Three groups emerged by cluster analysis. Urodynamic parameters and urinary function outcomes were compared between three groups. Group 1 (n = 44) had ideal urodynamic parameters with a mean maximal bladder capacity of 513.3 ml and mean residual urine volume of 33.1 ml. Group 2 (n = 42) was characterized by small bladder capacity with low compliance. Patients in group 2 had higher rates of daytime incontinence and nighttime incontinence than patients in group 1. Group 3 (n = 17) was characterized by large residual urine volume with high compliance. When we examined gender differences in urodynamics and functional outcomes, residual urine volume and the rate of daytime incontinence were only marginally significant. However, females were significantly more likely to belong to group 2 or 3 (P = 0.003). In multivariate analysis to identify factors associated with group 1 which has the most ideal urodynamic pattern, age (OR 0.95, P = 0.017) and male gender (OR 7.57, P = 0.003) were identified as significant factors. While patients with ileal neobladder present with various voiding symptoms, three urodynamic patterns were identified by cluster analysis. Approximately half of patients had ideal urodynamic parameters. The other two groups were characterized by large residual urine and small capacity bladder with low compliance. Young age and male gender appear to have a favorable impact on urodynamic and voiding outcomes in patients undergoing orthotopic neobladder reconstruction.

  15. Integrated next-generation sequencing of 16S rDNA and metaproteomics differentiate the healthy urine microbiome from asymptomatic bacteriuria in neuropathic bladder associated with spinal cord injury

    PubMed Central

    2012-01-01

    Background Clinical dogma is that healthy urine is sterile and the presence of bacteria with an inflammatory response is indicative of urinary tract infection (UTI). Asymptomatic bacteriuria (ABU) represents the state in which bacteria are present but the inflammatory response is negligible. Differentiating ABU from UTI is diagnostically challenging, but critical because overtreatment of ABU can perpetuate antimicrobial resistance while undertreatment of UTI can result in increased morbidity and mortality. In this study, we describe key characteristics of the healthy and ABU urine microbiomes utilizing 16S rRNA gene (16S rDNA) sequencing and metaproteomics, with the future goal of utilizing this information to personalize the treatment of UTI based on key individual characteristics. Methods A cross-sectional study of 26 healthy controls and 27 healthy subjects at risk for ABU due to spinal cord injury-related neuropathic bladder (NB) was conducted. Of the 27 subjects with NB, 8 voided normally, 8 utilized intermittent catheterization, and 11 utilized indwelling Foley urethral catheterization for bladder drainage. Urine was obtained by clean catch in voiders, or directly from the catheter in subjects utilizing catheters. Urinalysis, urine culture and 16S rDNA sequencing were performed on all samples, with metaproteomic analysis performed on a subsample. Results A total of 589454 quality-filtered 16S rDNA sequence reads were processed through a NextGen 16S rDNA analysis pipeline. Urine microbiomes differ by normal bladder function vs. NB, gender, type of bladder catheter utilized, and duration of NB. The top ten bacterial taxa showing the most relative abundance and change among samples were Lactobacillales, Enterobacteriales, Actinomycetales, Bacillales, Clostridiales, Bacteroidales, Burkholderiales, Pseudomonadales, Bifidobacteriales and Coriobacteriales. Metaproteomics confirmed the 16S rDNA results, and functional human protein-pathogen interactions were noted in subjects where host defenses were initiated. Conclusions Counter to clinical belief, healthy urine is not sterile. The healthy urine microbiome is characterized by a preponderance of Lactobacillales in women and Corynebacterium in men. The presence and duration of NB and method of urinary catheterization alter the healthy urine microbiome. An integrated approach of 16S rDNA sequencing with metaproteomics improves our understanding of healthy urine and facilitates a more personalized approach to prevention and treatment of infection. PMID:22929533

  16. Atypical squamous cells in the urine revealing endometrioid adenocarcinoma of the endometrium with squamous cell differentiation: a case report.

    PubMed

    Wang, Yinong; Otis, Christopher N; Florence, Roxanne R

    2015-01-01

    Urine cytology is mainly used to detect urothelial carcinoma (UC), especially for high-grade lesions including urothelial carcinoma in situ. Benign squamous cells are often seen in the urine specimens of women, they are either exfoliated from the trigone area of the bladder, the urethra, or the cervicovaginal region. However, abnormal squamous cells in the urine raise concerns of abnormalities of the urinary tract and cervicovaginal area which range from squamous metaplasia of the urothelium, a cervicovaginal squamous intraepithelial lesion, condyloma acuminatum of the bladder, UC with squamous differentiation, and squamous cell carcinoma. We present here a unique case of atypical squamous cells (ASCs) in the urine subsequently leading to the diagnosis of endometrioid adenocarcinoma of the endometrium with squamous differentiation. The presence of ASCs in voided urine is a rare finding that may indicate an underlying malignancy. Careful evaluation of squamous cells in the urine is an important part of our daily cytopathology practice. © 2014 Wiley Periodicals, Inc.

  17. Monitoring of chromium and nickel in biological fluids of grinders grinding stainless steel.

    PubMed

    Stridsklev, Inger Cecilie; Schaller, Karl-Heinz; Langård, Sverre

    2007-04-01

    Stainless steel (SS) welders usually spend some of their working time grinding, to finish and smoothen the welding groove. The aim of this study was to investigate possible relations between the concentrations of nickel (Ni) and chromium (Cr) in the work atmosphere generated by grinders grinding SS, and to compare the air levels to the levels of Cr and Ni in their biological fluids. Hereby, it might be possible to identify the contribution of grinding to the levels of Cr and Ni in biological fluids in SS welders. Also the airborne levels of Cr and Ni in SS grinders were compared to corresponding levels in SS welders. The subjects examined in this study were selected among SS grinders not performing welding. Nine grinders were monitored for 1 workweek, measuring Cr and Ni in air, blood and urine. They were questioned about their exposure to Cr and Ni during their working careers. Air levels of total Cr up to 95 microg/m(3) and Ni levels up to 25 microg/m(3) were measured. Chromium(VI) (Cr(VI)) was detectable only in five air samples; the levels in the remaining samples were below the detection limit. The levels of Cr in blood and urine were also low. The levels of Ni in urine were close to those for MMA and MIG/MAG SS welders. In spite of high levels of total Cr and Ni observed in air, the levels found in biological fluids were low. The Cr levels in more than 50% of the whole blood and red cell samples and about 1/3 of the Cr-plasma levels were below the detection limits. The mean blood levels for Cr were 0.43, 0.60 and 0.35 microg/l, in whole blood, plasma and red cells, respectively. The mean levels for Cr in the urine was 1.6, 1.4 and 1.4 microg/g creatinine for the first void, just before and just after work. For Ni the mean blood levels were 0.87 microg/l in whole blood and 0.68 microg/l in plasma. The mean levels and ranges of Ni from the first void, just before and after work in urine were 3.79 microg/g creatinine, 3.39 and 4.56, respectively. The Cr concentrations found in whole blood, plasma and red cells were approximately the same as those found in the unexposed controls and among TIG SS welders, while the urinary levels were somewhat higher, but still lower than in the welders applying other welding techniques. The mean levels of Ni in the urine of grinders were higher than those of welders, except for SS welders welding the MIG/MAG-method. SS Grinding seems not to contribute significantly to the uptake of Cr, which may be explained by the fact that most of Cr in the air is present in the metallic (0-valent) or trivalent form, and hardly any as Cr(VI), and therefore hardly being taken up in the airways. The grinders' uptake of Ni seems to take place to the same extent as in SS welders.

  18. Validity of predictive equations for 24-h urinary sodium excretion in adults aged 18–39 y12345

    PubMed Central

    Wang, Chia-Yih; Chen, Te-Ching; Pfeiffer, Christine M; Elliott, Paul; Gillespie, Cathleen D; Carriquiry, Alicia L; Sempos, Christopher T; Liu, Kiang; Perrine, Cria G; Swanson, Christine A; Caldwell, Kathleen L; Loria, Catherine M

    2013-01-01

    Background: Collecting a 24-h urine sample is recommended for monitoring the mean population sodium intake, but implementation can be difficult. Objective: The objective was to assess the validity of published equations by using spot urinary sodium concentrations to predict 24-h sodium excretion. Design: This was a cross-sectional study, conducted from June to August 2011 in metropolitan Washington, DC, of 407 adults aged 18–39 y, 48% black, who collected each urine void in a separate container for 24 h. Four timed voids (morning, afternoon, evening, and overnight) were selected from each 24-h collection. Published equations were used to predict 24-h sodium excretion with spot urine by specimen timing and race-sex subgroups. We examined mean differences with measured 24-h sodium excretion (bias) and individual differences with the use of Bland-Altman plots. Results: Across equations and specimens, mean bias in predicting 24-h sodium excretion for all participants ranged from −267 to 1300 mg (Kawasaki equation). Bias was least with International Cooperative Study on Salt, Other Factors, and Blood Pressure (INTERSALT) equations with morning (−165 mg; 95% CI: −295, 36 mg), afternoon (−90 mg; −208, 28 mg), and evening (−120 mg; −230, −11 mg) specimens. With overnight specimens, mean bias was least when the Tanaka (−23 mg; 95% CI: −141, 95 mg) or Mage (−145 mg; −314, 25 mg) equations were used but was statistically significant when using the Tanaka equations among females (216 to 243 mg) and the Mage equations among races other than black (−554 to −372 mg). Significant over- and underprediction occurred across individual sodium excretion concentrations. Conclusions: Using a single spot urine, INTERSALT equations may provide the least biased information about population mean sodium intakes among young US adults. None of the equations evaluated provided unbiased estimates of individual 24-h sodium excretion. This trial was registered at clinicaltrials.gov as NCT01631240. PMID:24047921

  19. The urine metabolome differs between lean and overweight Labrador Retriever dogs during a feed-challenge.

    PubMed

    Söder, Josefin; Hagman, Ragnvi; Dicksved, Johan; Lindåse, Sanna; Malmlöf, Kjell; Agback, Peter; Moazzami, Ali; Höglund, Katja; Wernersson, Sara

    2017-01-01

    Obesity in dogs is an increasing problem and better knowledge of the metabolism of overweight dogs is needed. Identification of molecular changes related to overweight may lead to new methods to improve obesity prevention and treatment. The aim of the study was firstly to investigate whether Nuclear Magnetic Resonance (NMR) based metabolomics could be used to differentiate postprandial from fasting urine in dogs, and secondly to investigate whether metabolite profiles differ between lean and overweight dogs in fasting and postprandial urine, respectively. Twenty-eight healthy intact male Labrador Retrievers were included, 12 of which were classified as lean (body condition score (BCS) 4-5 on a 9-point scale) and 16 as overweight (BCS 6-8). After overnight fasting, a voided morning urine sample was collected. Dogs were then fed a high-fat mixed meal and postprandial urine was collected after 3 hours. Metabolic profiles were generated using NMR and 45 metabolites identified from the spectral data were evaluated using multivariate data analysis. The results revealed that fasting and postprandial urine differed in relative metabolite concentration (partial least-squares discriminant analysis (PLS-DA) 1 comp: R2Y = 0.4, Q2Y = 0.32; cross-validated ANOVA: P = 0.00006). Univariate analyses of discriminant metabolites showed that taurine and citrate concentrations were elevated in postprandial urine, while allantoin concentration had decreased. Interestingly, lean and overweight dogs differed in terms of relative metabolite concentrations in postprandial urine (PLS-DA 1 comp: R2Y = 0.5, Q2Y = 0.36, cross-validated ANOVA: P = 0.005) but not in fasting urine. Overweight dogs had lower postprandial taurine and a trend of higher allantoin concentrations compared with lean dogs. These findings demonstrate that metabolomics can differentiate 3-hour postprandial urine from fasting urine in dogs, and that postprandial urine metabolites may be more useful than fasting metabolites for identification of metabolic alterations linked to overweight. The lowered urinary taurine concentration in overweight dogs could indicate alterations in lipid metabolism and merits further investigation.

  20. The urine metabolome differs between lean and overweight Labrador Retriever dogs during a feed-challenge

    PubMed Central

    Söder, Josefin; Hagman, Ragnvi; Dicksved, Johan; Lindåse, Sanna; Malmlöf, Kjell; Agback, Peter; Moazzami, Ali; Höglund, Katja; Wernersson, Sara

    2017-01-01

    Obesity in dogs is an increasing problem and better knowledge of the metabolism of overweight dogs is needed. Identification of molecular changes related to overweight may lead to new methods to improve obesity prevention and treatment. The aim of the study was firstly to investigate whether Nuclear Magnetic Resonance (NMR) based metabolomics could be used to differentiate postprandial from fasting urine in dogs, and secondly to investigate whether metabolite profiles differ between lean and overweight dogs in fasting and postprandial urine, respectively. Twenty-eight healthy intact male Labrador Retrievers were included, 12 of which were classified as lean (body condition score (BCS) 4–5 on a 9-point scale) and 16 as overweight (BCS 6–8). After overnight fasting, a voided morning urine sample was collected. Dogs were then fed a high-fat mixed meal and postprandial urine was collected after 3 hours. Metabolic profiles were generated using NMR and 45 metabolites identified from the spectral data were evaluated using multivariate data analysis. The results revealed that fasting and postprandial urine differed in relative metabolite concentration (partial least-squares discriminant analysis (PLS-DA) 1 comp: R2Y = 0.4, Q2Y = 0.32; cross-validated ANOVA: P = 0.00006). Univariate analyses of discriminant metabolites showed that taurine and citrate concentrations were elevated in postprandial urine, while allantoin concentration had decreased. Interestingly, lean and overweight dogs differed in terms of relative metabolite concentrations in postprandial urine (PLS-DA 1 comp: R2Y = 0.5, Q2Y = 0.36, cross-validated ANOVA: P = 0.005) but not in fasting urine. Overweight dogs had lower postprandial taurine and a trend of higher allantoin concentrations compared with lean dogs. These findings demonstrate that metabolomics can differentiate 3-hour postprandial urine from fasting urine in dogs, and that postprandial urine metabolites may be more useful than fasting metabolites for identification of metabolic alterations linked to overweight. The lowered urinary taurine concentration in overweight dogs could indicate alterations in lipid metabolism and merits further investigation. PMID:28662207

  1. Urine colorimetry for therapeutic drug monitoring of pyrazinamide during tuberculosis treatment.

    PubMed

    Zentner, Isaac; Modongo, Chawangwa; Zetola, Nicola M; Pasipanodya, Jotam G; Srivastava, Shashikant; Heysell, Scott K; Mpagama, Stellah; Schlect, Hans P; Gumbo, Tawanda; Bisson, Gregory P; Vinnard, Christopher

    2018-03-01

    Pyrazinamide is a key drug in the first-line treatment regimen for tuberculosis, with a potent sterilizing effect. Although low pyrazinamide peak serum concentrations (C max ) are associated with poor treatment outcomes, many resource-constrained settings do not have sufficient laboratory capacity to support therapeutic drug monitoring (TDM). The objective of this study was to determine whether a colorimetric test of urine can identify tuberculosis patients with adequate pyrazinamide exposures, as defined by serum C max above a target threshold. In the derivation study of healthy volunteers, three dose sizes of pyrazinamide were evaluated, and intensive pharmacokinetic blood sampling was performed over an 8-h period, with a timed urine void at 4h post-dosing. Pyrazinamide in urine was isolated by spin column centrifugation with an exchange resin, followed by colorimetric analysis; the absorbance peak at 495nm was measured. The urine assay was then evaluated in a study of 39 HIV/tuberculosis patients in Botswana enrolled in an intensive pharmacokinetic study. Receiver operating characteristics (ROC) curves were used to measure diagnostic accuracy. The guideline-recommended pyrazinamide serum C max target of 35mg/l was evaluated in the primary analysis; this target was found to be predictive of favorable outcomes in a clinical study. Following this, a higher serum C max target of 58mg/l was evaluated in the secondary analysis. At the optimal cut-off identified in the derivation sample, the urine colorimetric assay was 97% sensitive and 50% specific to identify 35 of 39 HIV/tuberculosis patients with pharmacokinetic target attainment, with an area under the ROC curve of 0.81 (95% confidence interval 0.60-0.97). Diagnostic accuracy was lower at the 58mg/l serum C max target, with an area under the ROC curve of 0.68 (95% confidence interval 0.48-0.84). Men were less likely than women to attain either serum pharmacokinetic target. The urine colorimetric assay was sensitive but not specific for the detection of adequate pyrazinamide pharmacokinetic exposures among HIV/tuberculosis patients in a high-burden setting. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Dose Reconstruction of Di(2-ethylhexyl) Phthalate Using a Simple Pharmacokinetic Model

    PubMed Central

    Calafat, Antonia M.

    2012-01-01

    Background: Di(2-ethylhexyl) phthalate (DEHP), used primarily as a plasticizer for polyvinyl chloride, is found in a variety of products. Previous studies have quantified human exposure by back calculating intakes based on DEHP metabolite concentrations in urine and by determining concentrations of DEHP in exposure media (e.g., air, food, dust). Objectives: To better understand the timing and extent of DEHP exposure, we used a simple pharmacokinetic model to “reconstruct” the DEHP dose responsible for the presence of DEHP metabolites in urine. Methods: We analyzed urine samples from eight adults for four DEHP metabolites [mono(2-ethylhexyl) phthalate, mono(2-ethyl-5-hydroxyhexyl) phthalate, mono(2-ethyl-5-oxohexyl) phthalate, and mono(2-ethyl-5-carboxypentyl) phthalate]. Participants provided full volumes of all voids over 1 week and recorded the time of each void and information on diet, driving, and outdoor activities. Using a model previously calibrated on a single person self-dosed with DEHP in conjunction with the eight participants’ data, we used a simple trial-and-error method to determine times and doses of DEHP that resulted in a best fit of predicted and observed urinary concentrations of the metabolites. Results: The average daily mean and median reconstructed DEHP doses were 10.9 and 5.0 µg/kg-day, respectively. The highest single modeled dose of 60 µg/kg occurred when one study participant reported consuming coffee and a bagel with egg and sausage that was purchased at a gas station. About two-thirds of all modeled intake events occurred near the time of reported food or beverage consumption. Twenty percent of the modeled DEHP exposure occurred between 2200 hours and 0500 hours. Conclusions: Dose reconstruction using pharmacokinetic models—in conjunction with biomonitoring data, diary information, and other related data—can provide a powerful means to define timing, magnitude, and possible sources of exposure to a given contaminant. PMID:23010619

  3. Diagnostic yield of lumbosacral magnetic resonance imaging requested by paediatric urology consultations.

    PubMed

    Fernández-Ibieta, M; Rojas Ticona, J; Villamil, V; Guirao Piñera, M J; López García, A; Zambudio Carmona, G

    2017-11-01

    In the historical series, the diagnostic yield of lumbosacral magnetic resonance imaging to rule out occult spinal dysraphism (or occult myelodysplasia), requested by paediatric urology, ranged from 2% to 15%. The aim of this study was to define our cost-effectiveness in children with urinary symptoms and to define endpoints that increase the possibility of finding occult spinal dysraphism. A screening was conducted on patients with urinary dysfunction for whom an magnetic resonance imaging was requested by the paediatric urology clinic, for persistent symptoms after treatment, voiding dysfunction or other clinical or urodynamic findings. We analysed clinical (UTI, daytime leaks, enuresis, voiding dysfunction, urgency, renal ultrasonography, lumbosacral radiography, history of acute urine retention, skin stigma and myalgia) and urodynamic endpoints (hyperactivity or areflexia, voiding dysfunction, interrupted pattern, accommodation value and maximum flow). A univariate analysis was conducted with SPSS 20.0. We analysed 21 patients during the period 2011-2015. The median age was 6 years (3-10). Three patients (14.3%) had occult spinal dysraphism: one spinal lipoma, one filum lipomatosus and one caudal regression syndrome with channel stenosis. The endpoints with statistically significant differences were the myalgias and the history of acute urine retention (66.7% vs. 5.6%, P=.04; OR= 34; 95%CI: 1.5-781 for both endpoints). The diagnostic yield of magnetic resonance imaging requested for children with urinary dysfunctions without skin stigma or neuro-orthopaedic abnormalities is low, although nonnegligible. In this group, the patients with a history of acute urine retention and muscle pain (pain, «cramps») can experience a greater diagnostic yield or positive predictive value. Copyright © 2017 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Biodegradable braided poly(lactic-co-glycolic acid) urethral stent combined with dutasteride in the treatment of acute urinary retention due to benign prostatic enlargement: a pilot study.

    PubMed

    Kotsar, Andres; Isotalo, Taina; Juuti, Hanne; Mikkonen, Joonas; Leppiniemi, Jenni; Hänninen, Venla; Kellomäki, Minna; Talja, Martti; Tammela, Teuvo L J

    2009-03-01

    To evaluate, in a pilot study, the efficacy and safety of combining a braided poly(lactic-co-glycolic acid) (PLGA, a copolymer of l-lactide and glycolide) urethral stent and dutasteride in the treatment of acute urinary retention (AUR) due to benign prostatic enlargement (BPE). Ten men with AUR due to BPE were treated as outpatients. A biodegradable braided PLGA urethral stent was inserted into the prostatic urethra, using a specially designed insertion device under visual control. Dutasteride treatment was started and the patients were followed up for 3 months after insertion of the stents. In all patients the stents were placed successfully with the new insertion device. All men were able to void after inserting the stent. At 1 month five patients voided freely with a low residual urine volume (<150 mL), two voided but had a high residual urine volume and a suprapubic catheter was placed, and three needed a suprapubic or an indwelling catheter before 1 month, due to AUR or comorbidities. At 3 months five patients were voiding with no problems. We have developed a new and effective insertion device for biodegradable braided prostatic stents. The new braided-pattern stent overcomes the earlier problems of migration and sudden breakage into large particles associated with biodegradable spiral stents. However, the mechanical properties of the new stent need to be improved and tested in a longer follow-up. We consider that this new biodegradable braided-pattern urethral stent could provide a new option in the future treatment of AUR.

  5. Evaluation of a colorimetric reagent strip assay for urine specific gravity.

    PubMed

    Kirschbaum, B B

    1983-06-01

    N-Multistix SG provides a convenient colorimetric assay for the determination of the specific gravity (sp. gr.) of freshly voided urine. When compared with results obtained by standard hydrometry, the colorimetric assay sp. gr. was observed to decrease by as much as 0.010 units as urine pH increased from 5 to 7. Moderate levels of proteinuria that did not alter hydrometer readings effectively raised the colorimetric sp. gr. by 0.005-0.010 units. The colorimetric assay was almost completely insensitive to clinically encountered concentrations of glucose and urea but responded appropriately to monovalent salts. The magnitude of these observed discrepancies places serious limitations on the value of the colorimetric sp. gr. measurement.

  6. European genome-wide association study identifies SLC14A1 as a new urinary bladder cancer susceptibility gene

    PubMed Central

    Rafnar, Thorunn; Vermeulen, Sita H.; Sulem, Patrick; Thorleifsson, Gudmar; Aben, Katja K.; Witjes, J. Alfred; Grotenhuis, Anne J.; Verhaegh, Gerald W.; Hulsbergen-van de Kaa, Christina A.; Besenbacher, Soren; Gudbjartsson, Daniel; Stacey, Simon N.; Gudmundsson, Julius; Johannsdottir, Hrefna; Bjarnason, Hjordis; Zanon, Carlo; Helgadottir, Hafdis; Jonasson, Jon Gunnlaugur; Tryggvadottir, Laufey; Jonsson, Eirikur; Geirsson, Gudmundur; Nikulasson, Sigfus; Petursdottir, Vigdis; Bishop, D. Timothy; Chung-Sak, Sei; Choudhury, Ananya; Elliott, Faye; Barrett, Jennifer H.; Knowles, Margaret A.; de Verdier, Petra J.; Ryk, Charlotta; Lindblom, Annika; Rudnai, Peter; Gurzau, Eugene; Koppova, Kvetoslava; Vineis, Paolo; Polidoro, Silvia; Guarrera, Simonetta; Sacerdote, Carlotta; Panadero, Angeles; Sanz-Velez, José I.; Sanchez, Manuel; Valdivia, Gabriel; Garcia-Prats, Maria D.; Hengstler, Jan G.; Selinski, Silvia; Gerullis, Holger; Ovsiannikov, Daniel; Khezri, Abdolaziz; Aminsharifi, Alireza; Malekzadeh, Mahyar; van den Berg, Leonard H.; Ophoff, Roel A.; Veldink, Jan H.; Zeegers, Maurice P.; Kellen, Eliane; Fostinelli, Jacopo; Andreoli, Daniele; Arici, Cecilia; Porru, Stefano; Buntinx, Frank; Ghaderi, Abbas; Golka, Klaus; Mayordomo, José I.; Matullo, Giuseppe; Kumar, Rajiv; Steineck, Gunnar; Kiltie, Anne E.; Kong, Augustine; Thorsteinsdottir, Unnur; Stefansson, Kari; Kiemeney, Lambertus A.

    2011-01-01

    Three genome-wide association studies in Europe and the USA have reported eight urinary bladder cancer (UBC) susceptibility loci. Using extended case and control series and 1000 Genomes imputations of 5 340 737 single-nucleotide polymorphisms (SNPs), we searched for additional loci in the European GWAS. The discovery sample set consisted of 1631 cases and 3822 controls from the Netherlands and 603 cases and 37 781 controls from Iceland. For follow-up, we used 3790 cases and 7507 controls from 13 sample sets of European and Iranian ancestry. Based on the discovery analysis, we followed up signals in the urea transporter (UT) gene SLC14A. The strongest signal at this locus was represented by a SNP in intron 3, rs17674580, that reached genome-wide significance in the overall analysis of the discovery and follow-up groups: odds ratio = 1.17, P = 7.6 × 10−11. SLC14A1 codes for UTs that define the Kidd blood group and are crucial for the maintenance of a constant urea concentration gradient in the renal medulla and, through this, the kidney's ability to concentrate urine. It is speculated that rs17674580, or other sequence variants in LD with it, indirectly modifies UBC risk by affecting urine production. If confirmed, this would support the ‘urogenous contact hypothesis’ that urine production and voiding frequency modify the risk of UBC. PMID:21750109

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hinwood, A.L., E-mail: a.hinwood@ecu.edu.au; Callan, A.C.; Ramalingam, M.

    Recent literature suggests that exposure to low concentrations of heavy metals may affect both maternal and child health. This study aimed to determine the biological heavy metals concentrations of pregnant women as well as environmental and dietary factors that may influence exposure concentrations. One hundred and seventy three pregnant women were recruited from Western Australia, each providing a sample of blood, first morning void urine, residential soil, dust and drinking water samples. Participants also completed a questionnaire which included a food frequency component. All biological and environmental samples were analysed for heavy metals using ICP-MS. Biological and environmental concentrations ofmore » lead and mercury were generally low (Median Pb Drinking Water (DW) 0.04 µg/L; Pb soil <3.0 µg/g; Pb dust 16.5 µg/g; Pb blood 3.67 µg/L; Pb urine 0.55; µg/L Hg DW <0.03; Hg soil <1.0 µg/g; Hg dust <1.0 µg/g; Hg blood 0.46 µg/L; Hg urine <0.40 µg/L). Cadmium concentrations were low in environmental samples (Median CdDW 0.02 µg/L; Cdsoil <0.30 ug/g; Cddust <0.30) but elevated in urine samples (Median 0.55 µg/L, creatinine corrected 0.70 µg/g (range <0.2–7.06 µg/g creatinine) compared with other studies of pregnant women. Predictors of increased biological metals concentrations in regression models for blood cadmium were residing in the Great Southern region of Western Australia and not using iron/folic acid supplements and for urinary cadmium was having lower household annual income. However, these factors explained little of the variation in respective biological metals concentrations. The importance of establishing factors that influence low human exposure concentrations is becoming critical in efforts to reduce exposures and hence the potential for adverse health effects. -- Highlights: • Biological heavy metals concentrations in women in their 3rd trimester of pregnancy. • Exposure assessment including environmental, lifestyle and activity data. • Urinary cadmium concentrations were elevated in this group of pregnant women. • Blood lead and mercury concentrations were below recommended biological guideline values.« less

  8. Quantification of Sulforaphane Mercapturic Acid Pathway Conjugates in Human Urine by High-Performance Liquid Chromatography and Isotope-Dilution Tandem Mass Spectrometry

    PubMed Central

    Egner, Patricia A.; Kensler, Thomas W.; Chen, Jian-Guo; Gange, Stephen J.; Groopman, John D.; Friesen, Marlin D.

    2011-01-01

    We report validation of the first high-pressure liquid chromatography isotope-dilution mass spectrometry method to measure sulforaphane (SFN) and its glutathione-derived conjugates in human urine. As epidemiological evidence continues to mount that the consumption of a diet rich in cruciferous vegetables may reduce the risk of certain cancers, the development of analytical methodologies to accurately measure isothiocyanates (ITCs) and their subsequent metabolic products becomes paramount. SFN, the principal ITC produced by broccoli, is an effective chemopreventive agent with multiple modes of action. SFN and SFN conjugates have often been measured collectively utilizing a cyclocondensation assay with 1,2-benzenedithiol. More recently, some of the major SFN conjugates have been determined using mass spectrometry. Here, triple-quadrupole mass spectrometry has been coupled with the use of stable isotope-labeled internal standards of D8-SFN and all four D8-SFN mercapturic acid pathway conjugates to provide an accurate, precise, sensitive, and specific method for analysis of these compounds. Using urine samples collected during an earlier intervention with broccoli sprouts, the concentrations of SFN, SFN-cysteine, and the mercapturic acid SFN-N-acetylcysteine were sufficiently high such that as little as 50 nL of urine was required for analysis. Although each study participant received an equivalent dose of broccoli sprout preparation, the interindividual conversion of the precursor glucosinolate to SFN varied over 100-fold. These 98 urines provided an ideal sample set for examining the robustness of the assay. The mean urinary concentrations ± standard deviations in overnight voids following ingestion of the first dose were 4.7 ± 5.1, 0.03 ± 0.05, 0.06 ± 0.06, 18 ± 15, and 42 ± 23 nmol/mg creatinine for SFN, SFN-glutathione, SFN-cysteine-glycine, SFN-cysteine, and SFN-N-acetylcysteine, respectively. This method determines SFN and all four SFN glutathione-derived metabolites with minimal sample preparation and will be extremely useful in understanding the role of SFN-rich foods in preventing cancer and other chronic diseases. PMID:18729326

  9. Impact of a bladder scan protocol on discharge efficiency within a care pathway for ambulatory inguinal herniorraphy.

    PubMed

    Antonescu, I; Baldini, G; Watson, D; Kaneva, P; Fried, G M; Khwaja, K; Vassiliou, M C; Carli, F; Feldman, L S

    2013-12-01

    Postoperative urinary retention (POUR) is a common complication of ambulatory inguinal herniorraphy, with an incidence reaching 38%, and many surgeons require patients to void before discharge. This study aimed to assess whether the implementation of a bladder scan-based voiding protocol reduces the time until discharge after ambulatory inguinal herniorraphy without increasing the rate of POUR. As part of a perioperative care pathway, a protocol was implemented to standardize decision making after elective inguinal hernia repair (February 2012). Patients were assessed with a bladder scan, and those with <600 mL of urine were discharged home, whereas those with more than 600 mL of urine had an in-and-out catheterization before discharge. The patients received written information about urinary symptoms and instructions to present to the emergency department if they were unable to void at home. An audit of scheduled outpatient inguinal hernia repairs between October 2011 and July 2012 was performed. Comparisons were made using the t test, Fisher's exact test, and Wilcoxon rank sum test where appropriate. Statistical significance was defined a priori as a p value lower than 0.05. During the study period, 124 patients underwent hernia repair: 60 before and 64 after implementation of the protocol. The findings showed no significant differences in patient characteristics, laparoscopic approach (35 vs. 33%; p = 0.80), proportion receiving general anesthesia (70 vs. 73%; p = 0.67), or amount of intravenous fluids given (793 vs. 663 mL; p = 0.07). The proportion of patients voiding before discharge was higher after protocol implementation (73 vs. 89%; p = 0.02). The protocol had no impact on median time to discharge (190 vs. 205 min; p = 0.60). Only one patient in each group presented to the emergency department with POUR (2%). After ambulatory inguinal herniorraphy, implementation of a bladder scan-based voiding protocol did not result in earlier discharge. The incidence of POUR was lower than reported in the literature.

  10. [Effect of the night shift work on micturition patterns of nurses].

    PubMed

    Wang, Q; Hu, H; Liang, C; Wang, J; Xu, K X

    2016-02-18

    To compare the effects of rotational night shifts on the micturition patterns of female nurses. A total of 58 nurses without lower urinary tract symptoms were recruited, who worked in the Peking University People's Hospital during January and June in 2014. The nurses aged 20-43 years were divided into two groups, the night-shift group (n=28) and the non-shift group (n=30). The alcohol or coffee intaking were forbidden. In the night-shift group, nurses had worked on rotational shifts for at least 6 months. Their average age was (26.75±4.11) years. In the non-shift group, nurses took regular day-time work, whose average age was (27.80±5.60) years. A voiding diary was kept for 7 consecutive days at the end of 6 months, starting 2 days before their night duties until 4 days after completion of their night duties. For comparison, the non-shift group with regular shifts completed a 7-day voiding diary. In the 7-day recording voiding diary, the nurses were required to have the normal intake of liquid about 1 500-2 000 mL/d. The frequency volume charts of nocturia, the 8-hour interval urine production and frequency were compared between the two groups. Nocturia frequency was increased in the night-shift group [0.5 (0-2.4)] compared with the non-shift group [0 (0-2), P=0.02]. The volume of nocturia was increased in the night-shift group [125 mL (0-660 mL)] compared with the non-shift group [0 mL (0-340 mL), P<0.01]. The 8-hour interval indices showed that urine production changed with shift (P<0.01). In the consecutive 7 days, the nocturnal volume of the night-shift group increased on the day after night shift. When the night-shift nurses returned to daytime duty, the volume of urine decreased but nocturnal urine production remained high, and the frequency of nocturia also increased significantly (P<0.05). Compared with the 8-hour interval indices, the night-shift group's voiding volume [(542.35±204.66) mL] and voiding frequency (2.24±0.69) were more than those of the non-shift group at the afternoon time (from 2 pm to 10 pm). During the 8 h interval night time (from 10 pm to 6 am), the volume of nocturia in the night-shift group [(309.74±162.74) mL] was more than that in the non-shift group [(199.38±153.98) mL, P=0.01]; the frequency of nocturia in the night-shift group (1.31±0.52) was increased than that in the non-shift group (0.82±0.55, P<0.01). The rotational shifts affect the micturition patterns of nurses who go through the night shift work, which increases the volume and frequency of the nocturia.

  11. [Effect of the night shift work on micturition patterns of nurses].

    PubMed

    Wang, Q; Hu, H; Liang, C; Wang, J; Xu, K X

    2016-08-18

    To compare the effects of rotational night shifts on the micturition patterns of female nurses. A total of 58 nurses without lower urinary tract symptoms were recruited, who worked in the Peking University People's Hospital during January and June in 2014. The nurses aged 20-43 years were divided into two groups, the night-shift group (n=28) and the non-shift group (n=30). The alcohol or coffee intaking were forbidden. In the night-shift group, nurses had worked on rotational shifts for at least 6 months. Their average age was (26.75±4.11) years. In the non-shift group, nurses took regular day-time work, whose average age was (27.80±5.60) years. A voiding diary was kept for 7 consecutive days at the end of 6 months, starting 2 days before their night duties until 4 days after completion of their night duties. For comparison, the non-shift group with regular shifts completed a 7-day voiding diary. In the 7-day recording voiding diary, the nurses were required to have the normal intake of liquid about 1 500-2 000 mL/d. The frequency volume charts of nocturia, the 8-hour interval urine production and frequency were compared between the two groups. Nocturia frequency was increased in the night-shift group [0.5 (0-2.4)] compared with the non-shift group [0 (0-2), P=0.02]. The volume of nocturia was increased in the night-shift group [125 mL (0-660 mL)] compared with the non-shift group [0 mL (0-340 mL), P<0.01]. The 8-hour interval indices showed that urine production changed with shift (P<0.01). In the consecutive 7 days, the nocturnal volume of the night-shift group increased on the day after night shift. When the night-shift nurses returned to daytime duty, the volume of urine decreased but nocturnal urine production remained high, and the frequency of nocturia also increased significantly (P<0.05). Compared with the 8-hour interval indices, the night-shift group's voiding volume [(542.35±204.66) mL] and voiding frequency (2.24±0.69) were more than those of the non-shift group at the afternoon time (from 2 pm to 10 pm). During the 8 h interval night time (from 10 pm to 6 am), the volume of nocturia in the night-shift group [(309.74±162.74) mL] was more than that in the non-shift group [(199.38±153.98) mL, P=0.01]; the frequency of nocturia in the night-shift group (1.31±0.52) was increased than that in the non-shift group (0.82±0.55, P<0.01). The rotational shifts affect the micturition patterns of nurses who go through the night shift work, which increases the volume and frequency of the nocturia.

  12. Does adenosine triphosphate released into voided urodynamic fluid contribute to urgency signaling in women with bladder dysfunction?

    PubMed

    Cheng, Ying; Mansfield, Kylie J; Allen, Wendy; Walsh, Colin A; Burcher, Elizabeth; Moore, Kate H

    2010-03-01

    Adenosine triphosphate released from urothelium during stretch stimulates afferent nerves and conveys information on bladder fullness. We measured adenosine triphosphate released during cystometric bladder filling in women with idiopathic detrusor overactivity and stress incontinence (controls), and assessed whether the level of released adenosine triphosphate is related to cystometric parameters. Routine cystometry was done in 51 controls and 48 women with detrusor overactivity who were 28 to 87 years old. Voided urodynamic fluid was collected and stored at -30 C. Adenosine triphosphate was measured by a bioluminescence assay. Adenosine triphosphate levels were similar in voided urodynamic fluid of controls and patients with detrusor overactivity (p = 0.79). A significant inverse correlation was seen between adenosine triphosphate and maximal cystometric capacity in controls (p = 0.013), and between voided volume and adenosine triphosphate in controls (p = 0.015) and detrusor overactivity cases (p = 0.019). A significant correlation between first desire to void and adenosine triphosphate was also noted in detrusor overactivity cases (p = 0.033) but not in controls (p = 0.58). No correlation was seen between adenosine triphosphate and detrusor pressure during filling or voiding. Adenosine triphosphate measurement in voided urodynamic fluid is a novel approach to understanding signals that may contribute to the urgency sensation (a sudden compelling desire to pass urine). The inverse correlation between adenosine triphosphate in voided urodynamic fluid and first desire to void suggests that adenosine triphosphate has a role in modulating the early filling sensation in patients with detrusor overactivity. 2010 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  13. Serotonin (5-HT)2A/2C receptor agonist (2,5-dimethoxy-4-idophenyl)-2-aminopropane hydrochloride (DOI) improves voiding efficiency in the diabetic rat.

    PubMed

    Tu, Hongjian; Cao, Nailong; Gu, Baojun; Si, Jiemin; Chen, Zhong; Andersson, Karl-Erik

    2015-07-01

    To examine the effects of the serotonin (5-HT)2A/2C receptor agonist (2,5-dimethoxy-4-idophenyl)-2-aminopropane hydrochloride (DOI) on micturition in rats with diabetes mellitus (DM). Female Sprague-Dawley rats (n = 16) were divided into two groups: rats with Type 1 DM and age-matched control rats. DM was induced by i.p. injection of streptozotocin (65 mg/kg) and detailed cystometrogram (CMG) studies were performed 8 weeks post-injection in all rats under urethane anaesthesia. The selective 5-HT2A antagonist ketanserin was administered after each DOI dose-response curve was plotted. All drugs were administered i.v. Compared with controls, comprehensive urodynamic studies showed that DM rats had a higher bladder capacity and post-void residual urine volume (PVR), and a markedly lower voiding efficiency. In DM rats, DOI (0.01-0.3 mg/kg) induced significant dose-dependent increases in micturition volume and reductions in PVR, resulting in greater voiding efficiency. CMG measurements showed a dose-dependent increase in high-frequency oscillation (HFO) activity, evidenced by an increased duration of HFOs per voiding. This correlated with the improved voiding efficiency. Ketanserin (0.1 mg/kg) partially or completely reversed the DOI-induced changes. The HFOs observed in the present study seem to correlate with external urethral sphincter bursting activity during voiding. Bladder voiding efficiency was reduced in DM rats. The 5-HT2A receptor agonist can enhance HFO activity and improves voiding efficiency, and so may represent a new strategy to improve voiding efficiency after DM in experimental studies. © 2014 The Authors BJU International © 2014 BJU International Published by John Wiley & Sons Ltd.

  14. Characterization of silodosin and naftopidil in the treatment of bladder dysfunction in the spontaneously hypertensive rat.

    PubMed

    Saito, Motoaki; Shimizu, Shogo; Ohmasa, Fumiya; Oikawa, Ryo; Tsounapi, Panagiota; Dimitriadis, Fotios; Kinoshita, Yukako; Satoh, Keisuke

    2013-04-01

    As increasing evidence suggest that α(1)-blockers prevent benign prostatic hyperplasia related overactive bladder and nocturia in the human, we investigated the effects of silodosin and naftopidil on hypertension-related bladder dysfunction in the spontaneously hypertensive rat (SHR) model. Twelve-week-old male SHRs received no treatment or treatment with silodosin (100 µg/kg, p.o.) or naftopidil (10 or 30 mg/kg, p.o.) once daily for 6 weeks. Wistar rats were used as normotensive controls. After 6-week treatment, voiding functions were estimated by metabolic cages (dark- and light-cycle separately) and cystometric studies. Furthermore, the bladder blood flow (BBF) was measured employing the hydrogen clearance method. SHRs showed significant increases in micturition frequency, and decreases in BBF and single voided volume in both metabolic cages and cystometrograms compared to the Wistar group. Treatment with silodosin normalized the decreased BBF, and treatment with naftopidil increased the BBF in a dose-dependent manner in the SHR group. Although treatment with silodosin and the high dose of naftopidil significantly inhibited micturition frequency in one day, only treatment with the high dose of naftopidil significantly inhibited micturition frequency and urine production in the light-cycle compared to the non-treated SHRs. Although treatment with silodosin and the high dose of naftopidil significantly increased single voided volume, only treatment with silodosin significantly inhibited non-voiding contractions in the cystometrgrams. Our data suggest that both silodosin and naftopidil improve hypertension-related bladder dysfunction in the SHR, and naftopidil but not silodosin improves urinary frequency in the light-cycle due to inhibition of urine production. Copyright © 2012 Wiley Periodicals, Inc.

  15. [The diagnostic value of microsatellite LOH analysis and the prognostic relevance of angiogenic gene expression in urinary bladder cancer].

    PubMed

    Szarvas, Tibor

    2009-12-01

    Bladder cancer is the second most common malignancy affecting the urinary system. Currently, histology is the only tool that determines therapy and patients' prognosis. As the treatment of non-invasive (Ta/T1) and muscle invasive (T2-T4) bladder tumors are completely different, correct staging is important, although it is often hampered by disturbing factors. Molecular methods offer new prospects for early disease detection, confirmation of unclear histological findings and prognostication. Applying molecular biological methods, the present study is searching for answers to current diagnostic and prognostic problems in bladder carcinoma. We analyzed tumor, blood and/or urine samples of 334 bladder cancer patients and 117 control individuals. Genetic alterations were analyzed in urine samples of patients and controls, both by PCR-based microsatellite loss of heterozigosity (LOH) analysis using 12 fluorescently labeled primers and by DNA hybridization based UroVysion FISH technique using 4 probes, to assess the diagnostic values of these methods. Whole genome microsatellite analysis (with 400 markers) was performed in tumor and blood specimens of bladder cancer patients to find chromosomal regions, the loss of which may be associated with tumor stage. Furthermore, we assessed the prognostic value of Tie2, VEGF, Angiopoietin-1 and -2. We concluded that DNA analysis of voided urine samples by microsatellite analysis and FISH are sensitive and non-invasive methods to detect bladder cancer. Furthermore, we established a panel of microsatellite markers that could differentiate between non-invasive and invasive bladder cancer. However, further analyses in a larger cohort of patients are needed to assess their specificity and sensitivity. Finally, we identified high Ang-2 and low Tie2 gene expression as significant and independent risk factors of tumor recurrence and cancer related survival.

  16. Increased Urine Production Due to Leg Fluid Displacement Reduces Hours of Undisturbed Sleep.

    PubMed

    Kiba, Keisuke; Hirayama, Akihide; Yoshikawa, Motokiyo; Yamamoto, Yutaka; Torimoto, Kazumasa; Shimizu, Nobutaka; Tanaka, Nobumichi; Fujimoto, Kiyohide; Uemura, Hirotsugu

    2017-07-03

    To investigate whether or not the leg fluid displacement observed when moving from the standing to recumbent position at bedtime reduces the hours of undisturbed sleep (HUS). Men aged 50 years or older who were hospitalized for urological diseases were investigated. Body water evaluation was performed three times with a bioelectric impedance method: (i) 17:00, (ii) 30 min after (short-term), and (iii) waking up (long-term). A frequency volume chart was used to evaluate the status of nocturnal urine production, and the factors affecting HUS were investigated. A total of 50 patients (mean age: 68 years) were enrolled. Short-term changes in extracellular fluid (ECF in the legs showed a significant positive correlation with urine production per unit of time at the first nocturnal voiding (UFN/HUS) (r = 0.45, P = 0.01). In the comparison between patients who had <3 HUS vs. those who had ≥3 HUS, the <3 HUS group showed significantly greater short-term changes in leg fluid volume, night-time water intake (17:00-06:00), and UFN/HUS. Multivariate analysis to assess the risk factors for <3 HUS indicated UFN/HUS as a risk factor in the overall model, and short-term changes in leg ECF and night-time water intake as risk factors in the model that only considered factors before sleep. Nocturnal leg fluid displacement may increase urine production leading up to first voiding after going to bed, and consequently, induce early awakening after falling asleep. © 2017 John Wiley & Sons Australia, Ltd.

  17. Loxoprofen sodium treatment for elderly men with refractory nocturia: effect on night-time urine production.

    PubMed

    Okada, Shinsuke; Watanabe, Hideki; Kojima, Yoshiyuki; Yanai, Yoshimasa; Sasaki, Shoichi; Kohri, Kenjiro

    2008-05-01

    We evaluated the efficacy of loxoprofen sodium for refractory nocturia. Twelve men (mean age, 75.1 +/- 5.7) with nocturia were enrolled in this study. All patients received 60 mg loxoprofen sodium prior to sleeping at night for 14 days. Nine of 12 patients (75%) felt more satisfaction than previous treatments. Patients were grouped into a loxoprofen sodium-effective (n = 7) and ineffective groups (n = 5) based on the results of the frequency-volume chart. In the effective group, interestingly, night-time urine volume showed significant reduction (P < 0.05). On the other hand, the average single voided volume at night and 24-h urine volume showed no significant change. There was a statistically significant difference in the night-time urine volume after treatment between groups (P < 0.01). Loxoprofen sodium is an effective treatment for some patients with refractory nocturia. The main effect mechanism of loxoprofen sodium may involve the reduction of night-time urine production.

  18. The dark matter of galaxy voids

    NASA Astrophysics Data System (ADS)

    Sutter, P. M.; Lavaux, Guilhem; Wandelt, Benjamin D.; Weinberg, David H.; Warren, Michael S.

    2014-03-01

    How do observed voids relate to the underlying dark matter distribution? To examine the spatial distribution of dark matter contained within voids identified in galaxy surveys, we apply Halo Occupation Distribution models representing sparsely and densely sampled galaxy surveys to a high-resolution N-body simulation. We compare these galaxy voids to voids found in the halo distribution, low-resolution dark matter and high-resolution dark matter. We find that voids at all scales in densely sampled surveys - and medium- to large-scale voids in sparse surveys - trace the same underdensities as dark matter, but they are larger in radius by ˜20 per cent, they have somewhat shallower density profiles and they have centres offset by ˜ 0.4Rv rms. However, in void-to-void comparison we find that shape estimators are less robust to sampling, and the largest voids in sparsely sampled surveys suffer fragmentation at their edges. We find that voids in galaxy surveys always correspond to underdensities in the dark matter, though the centres may be offset. When this offset is taken into account, we recover almost identical radial density profiles between galaxies and dark matter. All mock catalogues used in this work are available at http://www.cosmicvoids.net.

  19. Natural Ca Isotope Composition of Urine as a Rapid Measure of Bone Mineral Balance

    NASA Astrophysics Data System (ADS)

    Skulan, J.; Gordon, G. W.; Morgan, J.; Romaniello, S. J.; Smith, S. M.; Anbar, A. D.

    2011-12-01

    Naturally occurring stable Ca isotope variations in urine are emerging as a powerful tool to detect changes in bone mineral balance. Bone formation depletes soft tissue of light Ca isotopes while bone resorption releases isotopically light Ca into soft tissue. Previously published work found that variations in Ca isotope composition could be detected at 4 weeks of bed rest in a 90-day bed rest study (data collected at 4, 8 and 12 weeks). A new 30-day bed rest study involved 12 patients on a controlled diet, monitored for 7 days prior to bed rest and 7 days post bed rest. Samples of urine, blood and food were collected throughout the study. Four times daily blood samples and per void urine samples were collected to monitor diurnal or high frequency variations. An improved chemical purification protocol, followed by measurement using multiple collector inductively coupled plasma mass spectrometry (MC-ICP-MS) allowed accurate and precise determinations of mass-dependent Ca isotope variations in these biological samples to better than ±0.2% (δ44/42Ca) on <25 μg of Ca. Results from this new study show that Ca isotope ratios shift in a direction consistent with net bone loss after just 7 days, long before detectible changes in bone density by X-ray measurements occur. Consistent with this interpretation, the Ca isotope variations track changes observed in N-teleopeptide, a bone resorption biomarker. Bone-specific alkaline phosphatase, a bone formation biomarker, is unchanged over this period. Ca isotopes can in principle be used to quantify net changes in bone mass. Using a mass-balance model, our results indicate an average loss of 0.62 ± 0.16 % in bone mass over the course of this 30-day study. This is consistent with the rate of bone loss in longer-term studies as seen by X-ray measurements. This Ca isotope technique should accelerate the pace of discovery of new treatments for bone disease and provide novel insights into the dynamics of bone metabolism.

  20. Increased Urinary Adenosine Triphosphate in Patients With Bladder Outlet Obstruction Due to Benign Prostate Hyperplasia.

    PubMed

    Silva-Ramos, Miguel; Silva, Isabel; Oliveira, José Carlos; Correia-de-Sá, Paulo

    2016-11-01

    Diagnosis of bladder outflow obstruction (BOO) in patients with lower urinary tract (LUT) symptoms is challenging without using invasive urodynamic tests. Recently, we showed in vitro that urothelial strips from patients with benign prostatic hyperplasia (BPH) release more ATP than controls. Here, we tested whether urinary ATP can be used as a wall tension transducer non-invasive biomarker to detect BOO in patients with BPH. 79 male patients with BOO and 22 asymptomatic controls were recruited prospectively. Patients were asked to complete the International Prostate Symptom Score (IPSS) questionnaire and to void at normal desire into a urinary flowmeter; the postvoid residual volume was determined by suprapubic ultrasonography. Urine samples from all individuals were examined for ATP, creatinine, and lactate dehydrogenase. BOO patients had significantly higher (P < 0.001) urinary ATP normalized by the voided volume (456 ± 36 nmol) than age-matched controls (209 ± 35 nmol). Urinary ATP amounts increased with the voided volume, but the slope of this rise was higher in BOO patients than in controls. A negative correlation was detected between urinary ATP and flow rate parameters, namely maximal flow rate (r = -0.310, P = 0.005), Siroky flow-volume normalization (r = -0.324, P = 0.004), and volume-normalized flow rate index (r = -0.320, P = 0.012). We found no correlation with LUT symptoms IPSS score. Areas under the receiver operator characteristics (ROC) curves were 0.91 (95%CI 0.86-0.96, P < 0.001) for ATP alone and 0.88 (95%CI 0.81-0.94, P < 0,001) when adjusted to urinary creatinine. Patients with BOO release higher amounts of ATP into the urine than the control group. The high area under the ROC curve suggests that urinary ATP can be a high-sensitive non-invasive biomarker of BOO, which may have a discriminative value of detrusor competence when comparing BPH patients with low urinary flow rates. Prostate 76:1353-1363, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  1. Lung deposition and systemic bioavailability of different aerosol devices with and without humidification in mechanically ventilated patients.

    PubMed

    Moustafa, Islam O F; Ali, Mohammed R A-A; Al Hallag, Moataz; Rabea, Hoda; Fink, James B; Dailey, Patricia; Abdelrahim, Mohamed E A

    During mechanical ventilation medical aerosol delivery has been reported to be upto two fold greater with dry inhaled gas than with heated humidity. Urine levels at 0.5 h post dose (URSAL0.5%) has been confirmed as an index of lung deposition and 24 h (URSAL24%) as index of systemic absorption. Our aim was to determine the effect of humidification and aerosol device type on drug delivery to ventilated patients using urine levels. In a randomized crossover design, 36 (18female) mechanically ventilated patients were assigned to one of three groups. Groups 1 and 2 received 5000 μg salbutamol using vibrating mesh (VM) and jet nebulizers (JN), respectively, while group 3 received 1600 μg (16 puffs) of salbutamol via metered dose inhaler with AeroChamber Vent (MDI-AV). All devices were placed in the inspiratory limb of ventilator downstream from the humidifier. Each subject received aerosol with and without humidity at >24 h intervals with >12 h washout periods between salbutamol doses. Patients voided urine 15 min before each study dose and urine samples were collected at 0.5 h post dosing and pooled for the next 24 h. The MDI-AV and VM resulted in a higher percentage of urinary salbutamol levels compared to the JN (p < 0.05). Urine levels were similar between humidity and dry conditions. Our findings suggest that in-vitro reports overestimate the impact of dry vs. heated humidified conditions on the delivery of aerosol during invasive mechanical ventilation. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Urinary incontinence in women

    PubMed Central

    Aoki, Yoshitaka; Brown, Heidi W.; Brubaker, Linda; Cornu, Jean Nicolas; Daly, J. Oliver; Cartwright, Rufus

    2018-01-01

    Urinary incontinence symptoms are highly prevalent among women, have a substantial effect on health-related quality of life and are associated with considerable personal and societal expenditure. Two main types are described: stress urinary incontinence, in which urine leaks in association with physical exertion, and urgency urinary incontinence, in which urine leaks in association with a sudden compelling desire to void. Women who experience both symptoms are considered as having mixed urinary incontinence. Research has revealed overlapping potential causes of incontinence, including dysfunction of the detrusor muscle or muscles of the pelvic floor, dysfunction of the neural controls of storage and voiding, and perturbation of the local environment within the bladder. A full diagnostic evaluation of urinary incontinence requires a medical history, physical examination, urinalysis, assessment of quality of life and, when initial treatments fail, invasive urodynamics. Interventions can include non-surgical options (such as lifestyle modifications, pelvic floor muscle training and drugs) and surgical options to support the urethra or increase bladder capacity. Future directions in research may increasingly target primary prevention through understanding of environmental and genetic risks for incontinence. PMID:28681849

  3. Expression of ferrochelatase has a strong correlation in protoporphyrin IX accumulation with photodynamic detection of bladder cancer.

    PubMed

    Nakai, Yasushi; Tatsumi, Yoshihiro; Miyake, Makito; Anai, Satoshi; Kuwada, Masaomi; Onishi, Sayuri; Chihara, Yoshitomo; Tanaka, Nobumichi; Hirao, Yoshihiko; Fujimoto, Kiyohide

    2016-03-01

    The mechanism underlying the increased levels of protoporphyrin IX in bladder cancer remains unclear. Here, we focus on proteins associated with protoporphyrin IX accumulation in bladder cancer cells and investigate the protein that plays a key role in increased protoporphyrin IX accumulation in bladder cancer cells. Western blotting was used to determine the expression of peptide transporter 1, hydroxymethylbilane synthase, ferrochelatase, ATP-binding cassette 2, and heme oxygenase-1 in bladder cancer cell line cells. We evaluated the correlation between the expression of each protein and accumulated protoporphyrin IX in these cells using Pearson's correlation analysis. Immunohistochemistry was used to estimate the expression of the same five proteins in samples from 75 patients who underwent transurethral resection of bladder tumors. The correlation between the expression of each protein in cells from resected bladder specimens and accumulated protoporphyrin IX in bladder cancer cells in voided urine was evaluated using Pearson's correlation analysis. The expression of ferrochelatase showed a significant negative correlation with protoporphyrin IX accumulation in vitro (p=0.04). The expression of peptide transporter 1 (p<0.01, R=0.39), heme oxygenase-1 (p<0.01, R=0.33), and ferrochelatase (p<0.01, R=0.75) in resected bladder specimens by immunohistochemistry was correlated with protoporphyrin IX accumulation in bladder cancer cells in voided urine. On multivariate analysis, the expression of ferrochelatase (p=0.03) was significant factors to predict positive 5-aminolevulinic acid-induced fluorescent cytology. The expression of ferrochelatase has a strong correlation in protoporphyrin IX accumulation with photodynamic detection of bladder cancer. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Transcutaneous Electrical Nerve Stimulation in Children with Monosymptomatic Nocturnal Enuresis: A Randomized, Double-Blind, Placebo Controlled Study.

    PubMed

    Jørgensen, Cecilie Siggaard; Kamperis, Konstantinos; Borch, Luise; Borg, Britt; Rittig, Søren

    2017-09-01

    In a third of all children with monosymptomatic nocturnal enuresis their condition is refractory to first line treatments. Transcutaneous electrical nerve stimulation has been documented to be efficacious in children with daytime incontinence. We investigated the effect of transcutaneous electrical nerve stimulation in children with monosymptomatic nocturnal enuresis without nocturnal polyuria. Children with monosymptomatic nocturnal enuresis (3 or more wet nights per week) and no nocturnal polyuria were randomized to treatment with active or sham transcutaneous electrical nerve stimulation involving 1-hour sessions twice daily for 10 weeks in a double-blind design. Of the 52 children with monosymptomatic nocturnal enuresis included in the study 47 completed treatment (mean age 9.5 ± 2.1 years, 38 males). None of the children experienced a full response with complete remission of enuresis. Treatment with transcutaneous electrical nerve stimulation did not lead to significant changes in number of wet nights, nocturnal urine production on wet or dry nights, maximum voided volume with and without first morning voided volume, or voiding frequency when comparing parameters before and after treatment. The present study demonstrates no anti-enuretic effect of transcutaneous electrical nerve stimulation in children with monosymptomatic nocturnal enuresis without nocturnal polyuria. Nocturnal urine production and bladder capacity remained unchanged during and after treatment with transcutaneous electrical nerve stimulation. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  5. Bladder control, urgency, and urge incontinence: evidence from functional brain imaging.

    PubMed

    Griffiths, Derek; Tadic, Stasa D

    2008-01-01

    To review brain imaging studies of bladder control in subjects with normal control and urge incontinence; to define a simple model of supraspinal bladder control; and to propose a neural correlate of urgency and possible origins of urge incontinence. Review of published reports of brain imaging relevant to urine storage, and secondary analyses of our own recent observations. In a simple model of normal urine storage, bladder and urethral afferents received in the periaqueductal gray (PAG) are mapped in the insula, forming the basis of sensation; the anterior cingulate gyrus (ACG) provides monitoring and control; the prefrontal cortex makes voiding decisions. The net result, as the bladder fills, is inhibition of the pontine micturition center (PMC) and of voiding, together with gradual increase in insular response, corresponding to increasing desire to void. In urge-incontinent subjects, brain responses differ. At large bladder volumes and strong sensation, but without detrusor overactivity (DO), most cortical responses become exaggerated, especially in ACG. This may be both a learned reaction to previous incontinence episodes and the neural correlate of urgency. The neural signature of DO itself seems to be prefrontal deactivation. Possible causes of urge incontinence include dysfunction of prefrontal cortex or limbic system, suggested by weak responses and/or deactivation, as well as abnormal afferent signals or re-emergence of infantile reflexes. Bladder control depends on an extensive network of brain regions. Dysfunction in various parts may contribute to urge incontinence, suggesting that there are different phenotypes requiring different treatments. (c) 2007 Wiley-Liss, Inc.

  6. Age-Related Sleep Disruption and Reduction in the Circadian Rhythm of Urine Output: Contribution to Nocturia?

    PubMed Central

    Duffy, Jeanne F.; Scheuermaier, Karine; Loughlin, Kevin R.

    2015-01-01

    Aging is associated with a marked increase in sleep complaints, and one factor causing sleep disruption is waking to void (nocturia). Urological surveys have found that few young adults report nocturia symptoms, but about half of those in their 60’s and nearly 80% of older age groups are affected. Sleep surveys have found nocturia is a major cause of sleep disruption, with a majority of older adults with sleep disruption citing the need to void as the cause of their awakening. While much of the urological literature implies that nocturia causes sleep disruption, age-related changes in sleep depth and continuity may make it more likely that an older adult will wake in response to a filling bladder, or that an older adult will wake for another reason and then decide to void. There is also evidence that age-related changes in the amplitude of circadian rhythms contribute to nocturia. There is a well-described circadian rhythm in urine output, and evidence of circadian rhythmicity in some diuretic and anti-diuretic hormones. In this article we describe how age-related changes in sleep depth and continuity and age-related changes in circadian rhythm amplitude may contribute to nocturia, and how nocturia in turn leads to sleep disruption. Better understanding of how changes in sleep and circadian rhythmicity impact nocturia may lead to improved treatments and better quality of life for older adults. PMID:26632430

  7. Pathophysiology of nocturnal lower urinary tract symptoms in older patients with urinary incontinence.

    PubMed

    Denys, Marie-Astrid; Decalf, Veerle; Kumps, Candy; Petrovic, Mirko; Goessaert, An-Sofie; Everaert, Karel

    2017-11-01

    To explore the mismatch between functional bladder capacity and nocturnal urine production, and to study the pathophysiology of an increased nocturnal urine production in older patients with urinary incontinence. The present prospective observational study included adults aged ≥65 years with urinary incontinence. Participants completed questionnaires, frequency volume charts and renal function profiles. The nocturnal lower urinary tract symptom index was defined as nocturnal urine output/maximum voided volume; the nocturnal polyuria index as nocturnal/24 h urine output. The median age (n = 95) was 74 years (69-79), 87% were women and 73% had nocturnal lower urinary tract symptoms (nocturnal urinary incontinence or nocturia ≥2). Participants with nocturnal lower urinary tract symptoms had a significantly higher nocturnal urine output (809 mL vs 650 mL; P = 0.001) and no significant difference in maximum voided volume (350 mL vs 437 mL; P = 0.079) compared with participants without nocturnal lower urinary tract symptoms. Participants (nocturnal polyuria index >33% [n = 56], nocturnal polyuria index >40% [n = 42], nocturnal lower urinary tract symptom index >1.87 [n = 51]) showed higher night-time diuresis rates, free water and sodium clearance compared with during the daytime. Controls (nocturnal polyuria index ≤33% [n = 26], nocturnal polyuria index ≤40% [n = 40], nocturnal lower urinary tract symptom index ≤1.87 [n = 44]) had no circadian rhythm in their diuresis rate or sodium clearance, but more nocturnal free water clearance compared with during the daytime. The majority of older adults with urinary incontinence present nocturnal lower urinary tract symptoms. An increased nocturnal sodium diuresis seems to be the only mechanism differentiating patients with nocturnal lower urinary tract symptoms from controls. © 2017 The Japanese Urological Association.

  8. A pilot study on Trichomonas vaginalis in women with recurrent urinary tract infections.

    PubMed

    Chang, Po-Chih; Hsu, Yu-Chao; Hsieh, Ming-Li; Huang, Shih-Tsung; Huang, Hsin-Chieh; Chen, Yu

    2016-08-01

    Trichomoniasis and recurrent urinary tract infections (UTIs) shared similar risk factors, age distribution and overlapping symptoms. The aim of this study was to determine the prevalence of Trichomonas vaginalis (TV) in women with recurrent UTIs, attending a urology clinic in a medical center, in order to inform screening and treatment policies. Women with recurrent UTIs, defined as the presence of lower urinary tract symptoms (dysuria, frequency and urgency) and three positive urine cultures on voided urine specimens in the previous year, were enrolled prospectively from January 2013 to April 2014. Urine samples were collected for culture and tested for TV using immunochromatographic strip. Outpatient follow-up was arranged to diagnose any symptomatic UTI recurrence. Sixty-five women were recruited. Mean age was 57.4 ± 14.3 year-old and follow-up duration was 9.5 ± 4.0 months. The prevalence of TV was 16.9% (11/65). Eight women had UTI recurrence in the follow-up period. Recurrence rate did not differ in patients with and without concomitant TV infection. Given the high prevalence of TV, we suggest that testing for TV should be considered in women with recurrent UTIs. Further larger studies are needed to evaluate the potential benefit of treating TV in this group of patients. Copyright © 2016 Chang Gung University. Published by Elsevier B.V. All rights reserved.

  9. Risk factors for urinary tract infection in children with urinary urgency.

    PubMed

    Gondim, Rhaiana; Azevedo, Roberta; Braga, Ana Aparecida Nascimento Martinelli; Veiga, Maria Luiza; Barroso, Ubirajara

    2018-01-01

    To identify which independent variable would be strong predictor of febrile urinary tract infection (UTI) in children and adolescents with overactive bladder. A search was made of the institute's database for all patients diagnosed with overactive bladder over the preceding four years. Children and adolescents under 18 years of age with overactive bladder and no neurological or anatomical alterations of the lower urinary tract were included in the study. The independent variables were: sex, age, ethnicity (Brazilians of African descendence/others), the presence of urinary urgency, daytime incontinence, enuresis, frequent urination, infrequent voiding (≤3 voids/day), nocturia, holding maneuvers, straining to void, intermittent urinary flow, constipation and encopresis. An analysis was conducted to identify patients with febrile UTI and subsequently determine predictors of this condition. Univariate and multivariate analyses were performed. Overall, 326 patients (214 girls/112 boys) were evaluated. The mean age of the patients was 7.7±3.19 years (± standard deviation). The incidence of febrile UTI was 39.2%. Being female and infrequent voiding were factors significantly associated with febrile UTI, both in the univariate and multivariate analyses. These results show that being female and infrequent voiding constituted significant risk factors for a diagnosis of febrile UTI in these children. Copyright® by the International Brazilian Journal of Urology.

  10. Dysfunctional Elimination Behaviors and Associated Complications in School-Age Children

    ERIC Educational Resources Information Center

    Kistner, Mary

    2009-01-01

    Lack of privacy, risk of bullying, limited access, lack of essential products for good hygiene, and dirty bathrooms can all contribute to encouraging a child to withhold urine and stool while in school. Withholding behaviors over time can create a condition known as dysfunctional elimination syndrome (DES). DES is any pattern of voiding or…

  11. The sparkling Universe: clustering of voids and void clumps

    NASA Astrophysics Data System (ADS)

    Lares, Marcelo; Ruiz, Andrés N.; Luparello, Heliana E.; Ceccarelli, Laura; Garcia Lambas, Diego; Paz, Dante J.

    2017-07-01

    We analyse the clustering of cosmic voids using a numerical simulation and the main galaxy sample from the Sloan Digital Sky Survey. We take into account the classification of voids into two types that resemble different evolutionary modes: those with a rising integrated density profile (void-in-void mode or R-type) and voids with shells (void-in-cloud mode or S-type). The results show that voids of the same type have stronger clustering than the full sample. We use the correlation analysis to define void clumps, associations with at least two voids separated by a distance of at most the mean void separation. In order to study the spatial configuration of void clumps, we compute the minimal spanning tree and analyse their multiplicity, maximum length and elongation parameter. We further study the dynamics of the smaller sphere that enclose all the voids in each clump. Although the global densities of void clumps are different according to their member-void types, the bulk motions of these spheres are remarkably lower than those of randomly placed spheres with the same radius distribution. In addition, the coherence of pairwise void motions does not strongly depend on whether voids belong to the same clump. Void clumps are useful to analyse the large-scale flows around voids, since voids embedded in large underdense regions are mostly in the void-in-void regime, where the expansion of the larger region produces the separation of voids. Similarly, voids around overdense regions form clumps that are in collapse, as reflected in the relative velocities of voids that are mostly approaching.

  12. Health Risk Assessment and Urinary Excretion of Children Exposed to Arsenic through Drinking Water and Soils in Sonora, Mexico.

    PubMed

    García-Rico, Leticia; Meza-Figueroa, Diana; Jay Gandolfi, A; Del Rivero, Carlos Ibañez; Martínez-Cinco, Marco A; Meza-Montenegro, Maria M

    2018-05-02

    Environmental arsenic exposure is associated with increased risk of non-cancerous chronic diseases and a variety of cancers in humans. The aims of this study were to carry out for the first time a health risk assessment for two common arsenic exposure routes (drinking water and soil ingestion) in children living in the most important agricultural areas in the Yaqui and Mayo valleys in Sonora, Mexico. Drinking water sampling was conducted in the wells of 57 towns. A cross-sectional study was done in 306 children from 13 villages in the valleys. First morning void urine samples were analyzed for inorganic arsenic (InAs) and monomethyl and dimethyl arsenic (MMA and DMA) by HPLC/ICP-MS. The results showed a wide range of arsenic levels in drinking water between 2.7 and 98.7 μg As/L. Arsenic levels in agricultural and backyard soils were in the range of < 10-27 mg As/kg. The hazard index (HI) = ∑hazard quotient (HQ) for drinking water, agricultural soil, and backyard soil showed values > 1 in 100% of the study towns, and the carcinogenic risk (CR) was greater than 1E-04 in 85%. The average of arsenic excreted in urine was 31.7 μg As/L, and DMA had the highest proportion in urine, with averages of 77.8%, followed by InAs and MMA with 11.4 and 10.9%, respectively, percentages similar to those reported in the literature. Additionally, positive correlations between urinary arsenic levels and HI values were found (r = 0.59, P = 0.000). These results indicated that this population is at high risk of developing chronic diseases including cancer.

  13. Urinary polycyclic aromatic hydrocarbons as a biomarker of exposure to PAHs in air: a pilot study among pregnant women.

    PubMed

    Nethery, Elizabeth; Wheeler, Amanda J; Fisher, Mandy; Sjödin, Andreas; Li, Zheng; Romanoff, Lovisa C; Foster, Warren; Arbuckle, Tye E

    2012-01-01

    Recent studies have linked increased polycyclic aromatic hydrocarbons (PAHs) in air and adverse fetal health outcomes. Urinary PAH metabolites are of interest for exposure assessment if they can predict PAHs in air. We investigated exposure to PAHs by collecting air and urine samples among pregnant women pre-selected as living in "high" (downtown and close to steel mills, n=9) and "low" (suburban, n=10) exposure areas. We analyzed first-morning urine voids from all 3 trimesters of pregnancy for urinary PAH metabolites and compared these to personal air PAH/PM(2.5)/NO(2)/NO(X) samples collected in the 3rd trimester. We also evaluated activities and home characteristics, geographic indicators and outdoor central site PM(2.5)/NO(2)/NO(X) (all trimesters). Personal air exposures to the lighter molecular weight (MW) PAHs were linked to indoor sources (candles and incense), whereas the heavier PAHs were related to outdoor sources. Geometric means of all personal air measurements were higher in the "high" exposure group. We suggest that centrally monitored heavier MW PAHs could be used to predict personal exposures for heavier PAHs only. Urine metabolites were only directly correlated with their parent air PAHs for phenanthrene (Pearson's r=0.31-0.45) and fluorene (r=0.37-0.58). Predictive models suggest that specific metabolites (3-hydroyxyfluorene and 3-hydroxyphenanthrene) may be related to their parent air PAH exposures. The metabolite 2-hydroxynaphthalene was linked to smoking and the metabolite 1-hydroxypyrene was linked to dietary exposures. For researchers interested in predicting exposure to airborne lighter MW PAHs using urinary PAH metabolites, we propose that hydroxyfluorene and hydroxyphenanthrene metabolites be considered.

  14. Measuring Personal Exposure to Organophosphate Flame Retardants using Silicone Wristbands and Hand Wipes

    PubMed Central

    Hammel, Stephanie C.; Hoffman, Kate; Webster, Thomas F.; Anderson, Kim A.; Stapleton, Heather M.

    2016-01-01

    Organophosphate flame retardants (PFRs) are widely used as replacements for polybrominated diphenyl ethers in consumer products. With high detection in indoor environments and increasing toxicological evidence suggesting a potential for adverse health effects, there is a growing need for reliable exposure metrics to examine individual exposures to PFRs. Silicone wristbands have been used as passive air samplers for quantifying exposure in the general population and occupational exposure to polycyclic aromatic hydrocarbons. Here we investigated the utility of silicone wristbands in measuring exposure and internal dose of PFRs through measurement of urinary metabolite concentrations. Wristbands were also compared to hand wipes as metrics of exposure. Participants wore wristbands for five consecutive days and collected first morning void urine samples on three alternating days. Urine samples were pooled across the three days and analyzed for metabolites of the following PFRs: tris(1,3-dichloroisopropyl) phosphate (TDCIPP), tris(1-chloro-2-isopropyl) phosphate (TCIPP), triphenyl phosphate (TPHP), and mono-substituted isopropylated triaryl phosphate (mono-ITP). All four PFRs and their urinary metabolites were ubiquitously detected. Correlations between TDCIPP and TCIPP and their corresponding urinary metabolites were highly significant on the wristbands (rs= 0.5-0.65, p<0.001), which suggest that wristbands can serve as strong predictors of cumulative, five-day exposure and may be an improved metric compared to hand wipes. PMID:26975559

  15. Resistant starch alters gut microbiota and reduces uremic retention solutes in rats with adenine-induced chronic kidney disease

    USDA-ARS?s Scientific Manuscript database

    Chronic kidney disease (CKD) is characterized by the reduced ability to void urine, leading to accumulation of waste products in the body. Recently, it has been observed that patients with CKD have an altered gut microbiome. This may in part be due to reduced fiber intake. Patients with CKD are ofte...

  16. Extravasation of the contrast media during voiding cystourethrography in a long-term spinal cord injury patient.

    PubMed

    Kovindha, A; Sivasomboon, C; Ovatakanont, P

    2005-07-01

    To present complications and pitfalls in voiding cystourethrography (VCUG) and introduce a guideline for performing VCUG in a long-term spinal cord injury (SCI) patient with neurogenic bladder dysfunction (NBD) and contracted bladder. A case report. Maharaj Nakorn Chiang Mai Hospital, Chiang Mai, Thailand. We describe a chronic C(5) tetraplegic man with NBD and contracted bladder, who developed autonomic dysreflexia (AD), gross hematuria and extravasation of contrast median during VCUG. A foley catheter was retained after VCUG. AD was resolved and urine cleared after a week of continuous bladder irrigation. VCUG should be performed with caution in a long-term SCI patient with NBD and contracted bladder. Forceful pushing of the contrast media by the hand-injection method caused abrupt distention of the contracted bladder, damaged bladder mucosa and aggrevated AD. We suggest a guideline as follows: report bladder capacity and AD, if present, in an X-ray requisition form; use the gravity-drip method, stop the drip and drain the contrast media if a sudden headache and rising of blood pressure (BP) develop; observe urine colour, and report if bleeding or AD occurs.

  17. [Recommendations for the urodynamic examination in the investigation of non-neurological female urinary incontinence].

    PubMed

    Hermieu, Jean François

    2007-11-01

    INDICATIONS FOR URODYNAMIC ASSESSMENT IN WOMEN: Urodynamic assessment is not useful for the diagnosis of female urinary incontinence which remains a clinical diagnosis. Before any form of surgery for pure stress urinary incontinence, evaluation of bladder emptying by determination of maximum flow rate and residual urine is recommended. In the presence of pure stress urinary incontinence with no other associated clinical symptoms, a complete urodynamic assessment is not mandatory, but can be helpful to define the prognosis and inform the patient about her vesicosphincteric function. On the other hand, a complete urodynamic assessment is recommended to investigate complex or complicated urinary incontinence, mainly in the case of: history of surgery for urinary incontinence. urgency with or without urine leakage, severe urinary incontinence, voiding abnormalities, negative cough test, decreased bladder capacity, suspected obstruction or decreased bladder contractility, failure of first-line treatment. PATIENT PREPARATION: The patient should be thoroughly informed about the examination procedure and its possible consequences. The patient should be advised to attend the examination with a normal desire to urinate. Urodynamic assessment must not be performed in the presence of untreated urinary tract infection. Antibiotic prophylaxis is not recommended. UROFLOWMETRY: The flowmeter must be regularly calibrated and must be installed in a quiet room. Whenever possible, uroflowmetry should be performed before cystometry with a normal desire to urinate. The patient should be advised to urinate normally without straining and by staying as relaxed as possible. During voiding, all of the stream must enter the flowmeter. The main parameters recorded are Qmax (expressed in ml/s), the voided volume (expressed in ml), and the appearance of the curve. The examination must be interpreted manually without taking into account the automated interpretation. GUIDELINES CONCERNING CYSTOMETRY EQUIPMENT: A three pressure line configuration is recommended. Bladder filling must be performed with a sterile liquid; filling with gas is no longer recommended. Bladder filling is ideally performed by a pump ensuring a sufficiently slow flow rate to avoid modifying bladder behaviour (< 50 ml/min). It is essential to determine and check the volume infused into the bladder. When a peristaltic pump is used, the bladder filling catheter must be adapted to the pump. Water or electronic transducers can be used to measure bladder pressure. Balloon catheters filled with air appear to be sufficiently precise to perform pressure measurements in a manometric chamber (during cystometry) but not in a virtual cavity such as the urethra (during the urethral pressure profile). Measurement of abdominal pressure is recommended, either via the infusion catheter or preferably by a rectal balloon catheter. GUIDELINES ON THE PRACTICAL CONDITIONS OF CYSTOMETRY: The equipment must be regularly calibrated. Make sure that the bladder is empty before starting cystometry. Transducers are zeroed at the superior extremity of the pubic symphysis for infused transducers and at atmospheric pressure for electronic and air transducers. Tubings must be correctly connected without kinks, bubbles or leaks. The catheter must be selected according to its technical characteristics, particularly its pressure loss. After filling for one or two minutes, the patient is asked to cough to ensure a similar increase in both abdominal pressure and bladder pressure. The following parameters are recorded: baseline detrusor pressure, first desire to void, detrusor activity, bladder capacity and bladder compliance. Measurement of bladder pressure during voiding is used to confirm whether or not the bladder is contractile, assess obstruction in the case of low urine flow rate with high bladder pressure, and detect abdominal straining. Good test conditions must be ensured in order to obtain good quality voiding. In the case of incoherent results, the bladder should be re-filled after checking the equipment. MEASUREMENT AND INTERPRETATION OF URETHRAL PRESSURE: To obtain a reliable measurement of urethral pressure, it is recommended to: Define the normal values used. Use a catheter smaller than 12 F. Perform a circumferential measurement. Use a catheter with an infusion rate of 2 ml/min. Remove the catheter at a rate of 1 mm/s. Perform the examination in the seating or supine position with a half-full bladder after reducing any prolapse. Repeat the measurements. THE FOLLOWING ELEMENTS MUST BE TAKEN INTO ACCOUNT WHEN INTERPRETING AN URETHRAL PRESSURE PROFILE: The functional urethral length is neither a diagnostic criterion nor a prognostic criterion of urinary incontinence. The urethral pressure profile cannot be considered to be a useful test for the diagnosis of female urinary incontinence. However, in combination with clinical criteria, it is predictive of the results of female stress urinary incontinence surgical repair techniques. The pressure transmission ratio is neither a diagnostic criterion nor a prognostic criterion of urinary incontinence.

  18. Low frequency acoustic microscope

    DOEpatents

    Khuri-Yakub, Butrus T.

    1986-11-04

    A scanning acoustic microscope is disclosed for the detection and location of near surface flaws, inclusions or voids in a solid sample material. A focused beam of acoustic energy is directed at the sample with its focal plane at the subsurface flaw, inclusion or void location. The sample is scanned with the beam. Detected acoustic energy specularly reflected and mode converted at the surface of the sample and acoustic energy reflected by subsurface flaws, inclusions or voids at the focal plane are used for generating an interference signal which is processed and forms a signal indicative of the subsurface flaws, inclusions or voids.

  19. Morphological Segregation in the Surroundings of Cosmic Voids

    NASA Astrophysics Data System (ADS)

    Ricciardelli, Elena; Cava, Antonio; Varela, Jesus; Tamone, Amelie

    2017-09-01

    We explore the morphology of galaxies living in the proximity of cosmic voids, using a sample of voids identified in the Sloan Digital Sky Survey Data Release 7. At all stellar masses, void galaxies exhibit morphologies of a later type than galaxies in a control sample, which represent galaxies in an average density environment. We interpret this trend as a pure environmental effect, independent of the mass bias, due to a slower galaxy build-up in the rarefied regions of voids. We confirm previous findings about a clear segregation in galaxy morphology, with galaxies of a later type being found at smaller void-centric distances with respect to the early-type galaxies. We also show, for the first time, that the radius of the void has an impact on the evolutionary history of the galaxies that live within it or in its surroundings. In fact, an enhanced fraction of late-type galaxies is found in the proximity of voids larger than the median void radius. Likewise, an excess of early-type galaxies is observed within or around voids of a smaller size. A significant difference in galaxy properties in voids of different sizes is observed up to 2 R void, which we define as the region of influence of voids. The significance of this difference is greater than 3σ for all the volume-complete samples considered here. The fraction of star-forming galaxies shows the same behavior as the late-type galaxies, but no significant difference in stellar mass is observed in the proximity of voids of different sizes.

  20. Hem-o-lok clip: a neglected cause of severe bladder neck contracture and consequent urinary incontinence after robot-assisted laparoscopic radical prostatectomy.

    PubMed

    Cormio, Luigi; Massenio, Paolo; Lucarelli, Giuseppe; Di Fino, Giuseppe; Selvaggio, Oscar; Micali, Salvatore; Carrieri, Giuseppe

    2014-02-20

    Hem-o-lok clips are widely used during robot-assisted and laparoscopic radical prostatectomy to control the lateral pedicles. There are a few reports of hem-o-lok clip migration into the bladder or vesico-urethral anastomosis and only four cases of hem-o-lok clip migration resulting into bladder neck contracture. Herein, we describe the first case, to our knowledge, of hem-o-lok clip migration leading to severe bladder neck contracture and subsequent stress urinary incontinence. A 62-year-old Caucasian man underwent robot-assisted laparoscopic radical prostatectomy for a T1c Gleason 8 prostate cancer. One month after surgery the patient was fully continent; however, three months later, he presented with acute urinary retention requiring suprapubic drainage. Urethroscopy showed a hem-o-lok clip strongly attached to the area between the vesico-urethral anastomosis and the urethral sphincter and a severe bladder neck contracture behind it. Following cold-knife urethral incision and clip removal, the bladder neck contracture was widely resected. At 3-month follow-up, the patient voided spontaneously with a peak flow rate of 9.5 ml/sec and absence of post-void residual urine, but leaked 240 ml urine at the 24-hour pad test. To date, at 1-year follow-up, his voiding situation remains unchanged. The present report provides further evidence for the risk of hem-o-lok clip migration causing bladder neck contracture, and is the first to demonstrate the potential of such complication to result into stress urinary incontinence.

  1. Using urinary leucocyte esterase tests as an indicator of infection with gonorrhoea or chlamydia in asymptomatic males in a primary health care setting.

    PubMed

    Rahman, Md Saifur; Beever, Warwick; Skov, Steven; Boffa, John

    2014-02-01

    To evaluate a leucocyte esterase test as a predictor of gonorrhoea or chlamydia in asymptomatic Aboriginal males at the Central Australian Aboriginal Congress Male Clinic (Ingkintja), first-void urine samples and clinical information were collected from consecutive asymptomatic males presenting to the Ingkintja in Alice Springs between March 2008 and December 2009. Urine was tested immediately with a leucocyte esterase test dipstick and then by polymerase chain reaction for gonorrhoea and chlamydia. Among the 292 specimens from asymptomatic males, 15.4% were positive for gonorrhoea or chlamydia. In this group, compared with polymerase chain reaction result for gonorrhoea or chlamydia, leucocyte esterase test alone and in combination with age ≤35 years showed sensitivities of 66.7% and 60%, specificities of 90.7% and 94.7%, positive predictive values of 56.6% and 67.5%, negative predictive values of 93.7% and 92.8% and the area under receiver operating characteristics curve values of 0.79 and 0.85, respectively. Leucocyte esterase tests can reasonably be used as a basis for immediate empirical treatment for gonorrhoea or chlamydia in asymptomatic central Australian Aboriginal men under 35 years of age.

  2. Laboratory and exterior decay of wood plastic composite boards: voids analysis and computed tomography

    Treesearch

    Grace Sun; Rebecca E. Ibach; Meghan Faillace; Marek Gnatowski; Jessie A. Glaeser; John Haight

    2016-01-01

    After exposure in the field and laboratory soil block culture testing, the void content of wood–plastic composite (WPC) decking boards was compared to unexposed samples. A void volume analysis was conducted based on calculations of sample density and from micro-computed tomography (microCT) data. It was found that reference WPC contains voids of different sizes from...

  3. [Midline Cyst of the Prostate with Increased Urinary Frequency and Urgency : A Case Report].

    PubMed

    Nakano, Kosuke; Kiuchi, Hiroshi; Miyagawa, Yasushi; Tsujimura, Akira; Nonomura, Norio

    2018-02-01

    A 40-year-old man presented to our institution with a few-month history of increased urinary frequency, urgency and voiding difficulty. He had severe lower urinary tract symptoms with an International Prostate Symptom Score of 28 and quality of life score of 6. The mean urinary frequency and voided volume was 20 times per day and 150 ml, respectively. Abdominal ultrasonography and pelvic magnetic resonance imaging revealed the prostate measuring 15 cm3 with a 3 cm midline cyst which compressed the posterior of the bladder wall. A subsequent examination indicated that his lower urinary tract symptoms could be attributed to the cystic mass which mainly affected his storage symptoms. The patient underwent transurethral unroofing of the prostate cyst. Immediately after the surgery, his storage symptoms were improved greatly. The voiding volume was increased to 250 ml, and the frequency of urination was decreased to 8 times. No recurrent symptoms were found for seven months after the surgery.

  4. Herpes zoster-associated acute urinary retention: a case report.

    PubMed

    Julia, Jimmy J; Cholhan, Hilary J

    2007-01-01

    An 87-year-old woman presents with a 4-week history of urinary incontinence during which she had been treated for disseminated herpes zoster virus (HZV). On physical exam painful vesicles involving the entire vulvar region with mainly right sacral distribution were found. A catheterized volume exceeded 600 ml of retained urine after the patient failed to void spontaneously. Multichannel voiding-pressure urodynamic studies revealed an acontractile neurogenic bladder with overflow incontinence. The patient was discharged on a conservative regimen with arrangement for visiting nurse services to perform intermittent self-catheterization twice daily. Urodynamic testing was repeated 10 weeks after initial symptoms. During voiding cystometry a biphasic increase in detrusor pressure of 15 cm H2O was observed with no increase in abdominal pressure. The patient emptied 400 ml with a postvoid residual of 300 ml. Recovery from HZV-associated bladder emptying dysfunction can be achieved usually through conservative management, including intermittent self-catheterization. Complete recovery time ranges from 4 to 10 weeks.

  5. The "3 in 1" Study: Pooling Self-Taken Pharyngeal, Urethral, and Rectal Samples into a Single Sample for Analysis for Detection of Neisseria gonorrhoeae and Chlamydia trachomatis in Men Who Have Sex with Men.

    PubMed

    Sultan, B; White, J A; Fish, R; Carrick, G; Brima, N; Copas, A; Robinson, A; Gilson, R; Mercey, D; Benn, P

    2016-03-01

    Triple-site testing (using pharyngeal, rectal, and urethral/first-void urine samples) for Neisseria gonorrhoeae and Chlamydia trachomatis using nucleic acid amplification tests detects greater numbers of infections among men who have sex with men (MSM). However, triple-site testing represents a cost pressure for services. MSM over 18 years of age were eligible if they requested testing for sexually transmitted infections (STIs), reported recent sexual contact with either C. trachomatis or N. gonorrhoeae, or had symptoms of an STI. Each patient underwent standard-of-care (SOC) triple-site testing, and swabs were taken to form a pooled sample (PS) (pharyngeal, rectal, and urine specimens). The PS was created using two methods during different periods at one clinic, but we analyzed the data in combination because the sensitivity of the two methods did not differ significantly for C. trachomatis (P = 0.774) or N. gonorrhoeae (P = 0.163). The sensitivity of PS testing (92%) was slightly lower than that of SOC testing (96%) for detecting C. trachomatis (P = 0.167). For N. gonorrhoeae, the sensitivity of PS testing (90%) was significantly lower than that of SOC testing (99%) (P < 0.001). When pharynx-only infections were excluded, the sensitivity of PS testing to detect N. gonorrhoeae infections increased to 94%. Our findings show that pooling of self-taken samples could be an effective and cost-saving method, with high negative predictive values. (Interim results of this study were presented at the BASHH 2013 summer meeting.). Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  6. Performance evaluation of automated urine microscopy as a rapid, non-invasive approach for the diagnosis of non-gonococcal urethritis.

    PubMed

    Pond, Marcus J; Nori, Achyuta V; Patel, Sheel; Laing, Ken; Ajayi, Margarita; Copas, Andrew J; Butcher, Philip D; Hay, Phillip; Sadiq, Syed Tariq

    2015-05-01

    Gram-stained urethral smear (GSUS), the standard point-of-care test for non-gonococcal urethritis (NGU) is operator dependent and poorly specific. The performance of rapid automated urine flow cytometry (AUFC) of first void urine (FVU) white cell counts (UWCC) for predicting Mycoplasma genitalium and Chlamydia trachomatis urethral infections was assessed and its application to asymptomatic infection was evaluated. Receiver operating characteristic curve analysis, determining FVU-UWCC threshold for predicting M. genitalium or C. trachomatis infection was performed on 208 'training' samples from symptomatic patients and subsequently validated using 228 additional FVUs obtained from prospective unselected patients. An optimal diagnostic threshold of >29 UWC/µL gave sensitivities and specificities for either infection of 81.5% (95% CI 65.1% to 91.6%) and 85.8% (79.5% to 90.4%), respectively, compared with 86.8% (71.1% to 95%) and 64.7% (56.9% to 71.7%), respectively, for GSUS, using the training set samples. FVU-UWCC demonstrated sensitivities and specificities of 69.2% (95% CI 48.1% to 84.9%) and 92% (87.2% to 95.2%), respectively, when using validation samples. In asymptomatic patients where GSUS was not used, AUFC would have enabled more infections to be detected compared with clinical considerations only (71.4% vs 28.6%; p=0.03). The correlation between UWCC and bacterial load was stronger for M. genitalium compared with C. trachomatis (τ=0.426, p≤0.001 vs τ=0.295, p=0.022, respectively). AUFC offers improved specificity over microscopy for predicting C. trachomatis or M. genitalium infection. Universal AUFC may enable non-invasive diagnosis of asymptomatic NGU at the PoC. The degree of urethral inflammation exhibits a stronger association with pathogen load for M. genitalium compared with C. trachomatis. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  7. Efficiency control of dietary pesticide intake reduction by human biomonitoring.

    PubMed

    Göen, Thomas; Schmidt, Lukas; Lichtensteiger, Walter; Schlumpf, Margret

    2017-03-01

    In spite of food safety controls for pesticide residues, a conventional diet still leads to a noticeable exposure of the general population to several pesticides. In a pilot study the response of exposure reduction by organic diet intervention on the urinary levels of pesticide metabolites was investigated. In the study two adult individuals were kept on a conventional diet for 11days and morning urine voids were collected at the last four days of the period. Afterwards, the participants switched to exclusively organic food intake for 18days and likewise morning urine samples were collected at the last four days of this period. In the urine samples six pyrethroid metabolites, six dialkylphosphates, four phenolic parameter for organophosphate pesticides and carbamates, 6-chloronicotinic acid (ClNA) as parameter for neonicotinoid insecticides, seven phenoxy herbicides, glyphosate and its metabolite AMPA were quantified using gas chromatographic mass spectrometric methods. Generally, the comparative analyses revealed greater shares as well as higher levels of the parameters in the samples taken during the common diet period compared to the organic diet period. Considerable decrease of the levels was found for almost all pyrethroid metabolites, dialkyphosphates and phenoxy herbicids, as well as for the phenolic metabolites 4-nitrophenol and 3,5,6-trichloropyridinol. In contrast, higher values were found for the organic diet period for ClNA and the metabolite of coumaphos in one of the volunteers. The present study confirms the results of former studies which indicated that an organic diet intervention results in considerable lower exposure to organophosphate pesticides and pyrethroids. It also verifies the former experience that monitoring of urinary parameters for non-persistent pesticides permits a reliable efficiency control of short-time effects by dietary interventions. Additionally to former studies, the results of the present study highlight the need of an extension of the parameter spectrum to all prominent pesticide groups. Copyright © 2016 Elsevier GmbH. All rights reserved.

  8. Novel round cells in urine sediment and their clinical implications.

    PubMed

    Shukuya, Kenichi; Ogura, Sayoko; Tokuhara, Yasunori; Okubo, Shigeo; Yatomi, Yutaka; Tozuka, Minoru; Shimosawa, Tatsuo

    2016-06-01

    Voided urine contains a variety of cells from the kidney and urinary tract and urinalysis provides us various information by investigating cellular components. We investigated urine sediment from renal impaired patients. We found 'round cell' to be distinct from known cells in sediment and is close to proximal convoluted tubule-derived cells based on morphology and molecular marker expression (GGT1 but not podocalyxin). Also it was positive for undifferentiated cell markers, including PAX2, WT1, OSR1, and SIX2. They were observed in end-stage renal failure patients and the number of cells was correlated with the severity of chronic kidney disease. A prospective analysis revealed that patients who had more round cells were more likely to require hemodialysis within a year. Round cells are a novel marker that can be used to predict the need for hemodialysis. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ricciardelli, Elena; Tamone, Amelie; Cava, Antonio

    We explore the morphology of galaxies living in the proximity of cosmic voids, using a sample of voids identified in the Sloan Digital Sky Survey Data Release 7. At all stellar masses, void galaxies exhibit morphologies of a later type than galaxies in a control sample, which represent galaxies in an average density environment. We interpret this trend as a pure environmental effect, independent of the mass bias, due to a slower galaxy build-up in the rarefied regions of voids. We confirm previous findings about a clear segregation in galaxy morphology, with galaxies of a later type being found atmore » smaller void-centric distances with respect to the early-type galaxies. We also show, for the first time, that the radius of the void has an impact on the evolutionary history of the galaxies that live within it or in its surroundings. In fact, an enhanced fraction of late-type galaxies is found in the proximity of voids larger than the median void radius. Likewise, an excess of early-type galaxies is observed within or around voids of a smaller size. A significant difference in galaxy properties in voids of different sizes is observed up to 2 R {sub void}, which we define as the region of influence of voids. The significance of this difference is greater than 3 σ for all the volume-complete samples considered here. The fraction of star-forming galaxies shows the same behavior as the late-type galaxies, but no significant difference in stellar mass is observed in the proximity of voids of different sizes.« less

  10. Comparative Effectiveness of Anticholinergic Therapy for Overactive Bladder in Women: A Systematic Review and Meta-analysis.

    PubMed

    Reynolds, W Stuart; McPheeters, Melissa; Blume, Jeffery; Surawicz, Tanya; Worley, Katherine; Wang, Li; Hartmann, Katherine

    2015-06-01

    To summarize evidence about reduction in voiding and resolution of urine loss in overactive bladder comparing data from the active drug arms with the placebo arms of randomized trials. We searched MEDLINE, EMBASE, Cumulative Index to Nursing and Allied Health Literature, and ClinicalTrials.gov in March 2014. Multiple reviewers screened original research published in English on community-dwelling women with nonneurogenic overactive bladder undergoing pharmacotherapy with medications available in the United States. Studies in which women comprised less than 75% of the population or those with a sample size less than 50 were excluded. Study designs included randomized controlled trials for meta-analysis and cohorts, case-control, and case series for harms data. Our search identified 50 randomized controlled trials from among 144 candidate publications (one was of good quality, 38 fair, and 11 poor). Multiple team members performed data extraction independently with secondary review of data entry to ensure quality and validity. Studies were assessed for risk of bias. Meta-analysis was performed using fixed-effects regression models. The primary outcomes and measurements were the numbers of daily voids and urge incontinence episodes. Medications delivered as a daily dose reduced urge incontinence by 1.73 episodes per day (95% confidence interval [CI] 1.37-2.09) and voids by 2.06 per day (95% CI 1.66-2.46) from 2.79 (95% CI 0.70-4.88) and 11.28 (95% CI 7.77-14.80) at baseline, respectively. Placebo reduced urge incontinence episodes by 1.06 (95% CI 0.7-1.42) and voids by 1.2 (95% CI 0.72-1.67) per day. No individual agent demonstrated superiority over another. The majority (98%) of studies reporting funding were sponsored by industry. Evidence from more than 27,000 women participating in randomized controlled trials suggests that improvement in symptoms with anticholinergic management of overactive bladder is modest and rarely fully resolves symptoms.

  11. Urine testing to monitor the impact of HPV vaccination in Bhutan and Rwanda.

    PubMed

    Franceschi, Silvia; Chantal Umulisa, M; Tshomo, Ugyen; Gheit, Tarik; Baussano, Iacopo; Tenet, Vanessa; Tshokey, Tshokey; Gatera, Maurice; Ngabo, Fidele; Van Damme, Pierre; Snijders, Peter J F; Tommasino, Massimo; Vorsters, Alex; Clifford, Gary M

    2016-08-01

    Bhutan (2010) and Rwanda (2011) were the first countries in Asia and Africa to introduce national, primarily school-based, human papillomavirus (HPV) vaccination programmes. These target 12 year-old girls and initially included catch-up campaigns (13-18 year-olds in Bhutan and ninth school grade in Rwanda). In 2013, to obtain the earliest indicators of vaccine effectiveness, we performed two school-based HPV urine surveys; 973 female students (median age: 19 years, 5th-95th percentile: 18-22) were recruited in Bhutan and 912 (19 years, 17-20) in Rwanda. Participants self-collected a first-void urine sample using a validated protocol. HPV prevalence was obtained using two PCR assays that differ in sensitivity and type spectrum, namely GP5+/GP6+ and E7-MPG. 92% students in Bhutan and 43% in Rwanda reported to have been vaccinated (median vaccination age = 16, 5th-95th: 14-18). HPV positivity in urine was significantly associated with sexual activity measures. In Rwanda, HPV6/11/16/18 prevalence was lower in vaccinated than in unvaccinated students (prevalence ratio, PR = 0.12, 95% confidence interval, CI: 0.03-0.51 by GP5+/GP6+, and 0.45, CI: 0.23-0.90 by E7-MPG). For E7-MPG, cross-protection against 10 high-risk types phylogenetically related to HPV16 or 18 was of borderline significance (PR = 0.68; 95% CI: 0.45-1.01). In Bhutan, HPV6/11/16/18 prevalence by GP5+/GP6+ was lower in vaccinated than in unvaccinated students but CIs were broad. In conclusion, our study supports the feasibility of urine surveys to monitor HPV vaccination and quantifies the effectiveness of the quadrivalent vaccine in women vaccinated after pre-adolescence. Future similar surveys should detect increases in vaccine effectiveness if vaccination of 12 year-olds continues. © 2016 UICC.

  12. The optimal duration of frequency-volume charts related to compliance and reliability.

    PubMed

    van Haarst, Ernst P; Bosch, J L H Ruud

    2014-03-01

    To assess Frequency-volume charts (FVCs) for the yield of additional recorded days and the ideal duration of recording related to compliance and reliability. Of 500 consecutive urologic outpatients willing to complete a 7-day FVC, 378 FVCs were evaluable. During seven consecutive days every voiding time and volume were recorded. Missed entries were indicated with a coded letter, thereby assessing the true frequency and compliance. Reliability is the agreement of the day-to-day FVC parameters with the 7-day FVC pattern. Single-day reliability was assessed and used in the Spearman-Brown formula. FVCs of 228 male and 150 females were evaluated. Mean age was 55.2 years (standard deviation [SD]: 16.2 years), and mean 24-hr urine production was 1,856 ml (SD: 828 ml). The percentage of patients with complete FVCs decreased from 78% on day 2 to 58% on day 7, and dropped below 70% after 4 days. Single-day reliability was r = 0.63 for nocturnal urine production, r = 0.72 for 24-hr urine production, and r = 0.80 for mean voided volume. At 5 days, reliability of 90% was achieved for all parameters. With each additional day, FVCs showed a decrease in compliance and an increase in reliability. At day 3, reliability of 80% was achieved for all FVC parameters, but compliance dropped to 73%. Beyond 5 days, the yield of additional recorded days was limited. We advocate an FVC duration of 3 days, but the duration may be shortened or extended depending on the goal of the FVC. © 2013 Wiley Periodicals, Inc.

  13. Urodynamic characterization of lower urinary tract symptoms in men less than 40 years of age.

    PubMed

    Jamzadeh, Asha E; Xie, Donghua; Laudano, Melissa; Seklehner, Stephan; Elterman, Dean S; Shtromvaser, Lucien; Lee, Richard; Kaplan, Steven A; Te, Alexis E; Chughtai, Bilal

    2014-04-01

    Lower urinary tract symptoms (LUTS) in young men are becoming a more recognized urologic issue that can arise from many causes, each with their own management strategy. The purpose of this study was to determine the rates and types of voiding dysfunction causing LUTS in men under 40 years. Videourodynamic studies (VUDS) of 87 men 40 years of age or less with LUTS for greater than 6 months, performed between July 2004 and June 2012 at Weill Cornell Medical College, were retrospectively analyzed. Patients with culture-proven bacterial prostatitis, symptoms for less than 6 months, a history of neurologic disease, or previous urological surgery affecting voiding function were excluded from the analysis. The mean age of the patients was 31.84 ± 5.78. There were 37 patients that presented with more than one urinary symptom (42.5 %). The most frequent complaints included: urinary frequency (N = 42, 48.28 %), difficulty with urination (N = 41, 47.13 %), and urinary urgency (N = 21, 24.14 %). The most common urodynamic abnormality was bladder outlet obstruction (BOO) (N = 37, 42.53 %), dysfunctional voiding (N = 25, 28.74 %), detrusor underactivity (N = 10, 11.49 %), and detrusor overactivity (N = 7, 8.05 %). There were no differences seen in AUA symptom and quality of life scores across diagnosis groups. Lower urinary tract symptoms can present in younger men with a variety of types of voiding dysfunction. This study uses VUDS to show that the most common types of voiding dysfunction in this population with chronic LUTS are BOO followed by dysfunctional voiding.

  14. Management of non-neuropathic underactive bladder in children with voiding dysfunction by animated biofeedback: a randomized clinical trial.

    PubMed

    Ladi-Seyedian, Sanam; Kajbafzadeh, Abdol-Mohammad; Sharifi-Rad, Lida; Shadgan, Babak; Fan, Eileen

    2015-01-01

    To assess the efficacy of animated biofeedback and pelvic floor muscle (PFM) exercise in managing children with non-neuropathic underactive bladder (UB). A total of 50 children with UB without underlying neuropathic disease, aged 5-16 years, were included in this study. They were randomly divided into 2 equal treatment groups comprising standard urotherapy (hydration, scheduled voiding, toilet training, and diet) with (group A) or without (group B) animated biofeedback and PFM exercise. The follow-up period for each participant was 1 year. A complete voiding and bowel habit diary was recorded by participants' parents before and after 2 evaluations. In addition, uroflowmetry with electromyography and bladder ultrasound were performed before, 6 months, and 1 year after treatment. Results were compared between the 2 cohorts. Mean number of voiding episodes was significantly increased in group A after biofeedback therapy compared with group B with only standard urotherapy (6.6 ± 1.6 vs 4.5 ± 1 times a day; P <.000). Urinary tract infection did not relapse in 9 of 11 (81%) and 8 of 15 (38%) patients in groups A and B, respectively (P <.02). Postvoid residual volume and voiding time decreased considerably, whereas maximum urine flow increased significantly in group A compared with group B (17.2 ± 4.7 vs 12.9 ± 4.6 mL/s; P <.01). Combination of animated biofeedback and PFM exercise effectively improves sensation of bladder fullness and contractility in children with UB due to voiding dysfunction. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Pesticide risk perception and biomarkers of exposure in Florida female farmworkers.

    PubMed

    Runkle, Jennifer D; Tovar-Aguilar, J Antonio; Economos, Eugenia; Flocks, Joan; Williams, Bryan; Muniz, Juan F; Semple, Marie; McCauley, Linda

    2013-11-01

    To compare workplace characteristics, workplace behaviors, and the health beliefs of female farmworkers of childbearing age with actual biomarkers of exposure to organophosphate pesticides and to the fungicide mancozeb. Hispanic and Haitian farmworkers between the ages of 18 and 40 years working in nursery or fernery operations were recruited to participate in a cross-sectional survey, examining demographics, work practices, work-related hygiene, and pesticide exposure beliefs. Single-void (spot) urine samples were analyzed for organophosphate and ethylenethiourea metabolites. Women in nurseries worried less frequently about the effects of pesticides on their health than those in fernery operations. In summary, organophosphate and ethylenethiourea levels in nursery workers were significantly higher than levels in fernery workers and the control group. Results showed that perceived pesticide exposure did not correspond to actual metabolite levels within differing agricultural subpopulations.

  16. [Comparison of new portable home electronic uroflowmeter with Laborie uroflowmeter].

    PubMed

    Guan, Zhi-chen; Deng, Xiao-lin; Zhang, Qian

    2011-08-18

    To design a new portable home electronic uroflowmeter and compare it with traditional methods. The system consists of collectors, urine conducting apparatus, intelligent cell phone, wireless network communication technology, computer analysis and drawing, and data storage technology, etc., and can automatically collect voiding information from patients with lower urinary tract symptoms(LUTS) Through Bluetooth, the voiding information was sent to the patient's intelligent cell phone from the collector, then stored directly by intelligent cell phone and wirelessly transmitted to the workstation in hospital. The system was primarily tested with regard to accuracy of measurement of the voided volume. Multiple doses with known volume were introduced in the system and Laborie uroflowmeter. Furthermore, 38 outpatients who had LUTS were tested simultaneously with the system and Laborie uroflowmeter. The statistical method for assessing agreement between the two methods of clinical measurement was Bland-Altman analysis. Among the subjects, there were 22 male patients and 16 female patients, ranging from 21 to 37 years old, with an average age of 25.5 years, of whom, 19 were tested once and 19 patients twice, equaling to 57 tests. The system could accurately collect and analyze voiding time, uroflowmetry, voided volume, and automatically provide uroflowmetry parameters. The measurement error of 100, 200, 300, 500 and 800 mL is less than 5%. 12.28%, 5.26% and 3.51% of the Qmax, Qave and voided volume points were beyond the 95% limits of agreement. The maximum absolute values of the Qmax, Qave and voided volume difference were 0.38 mL/s, 0.70 mL/s and 2.90 mL, respectively.They agreed with the recommendation of Standardization International Continence Society. The new portable home electronic uroflowmeter has good agreement with Laborie uroflowmeter,and is a new LUTS monitoring system integrated with correct, reliable, real-time, convenient and easy-managing advantages. It is as noninvasive and reliable as traditional methods, and its portable feature facilitates application out of hospitals. It can also record voiding diaries.

  17. Neurostimulation and neuromodulation: a guide to selecting the right urologic patient.

    PubMed

    Schmidt, R A; Doggweiler, R

    1998-01-01

    Sensory input has an important influence on the integrity of neural circuitry. Central nervous system circuitry is programmed and reinforced by everyday experience. Even the simplest of behaviors participate in this process. A balance between inhibition and facilitation must be maintained for the CNS to function normally. For example, the bladder stores urine because of the inhibition from a closed sphincter, and relaxation of the sphincter disinhibits the bladder to permit voiding. This synergistic 'seesaw' in reflex neural activity preserves the functional and anatomical integrity of the lower urinary tract. Dysfunction and anatomical change results when an unnatural bias develops between inhibitory and facilitatory neural activity. Neurostimulation has an inherent conditioning effect on neural excitability and can restore the neural equilibrium. Voiding diaries are very useful in documenting these changes.

  18. ON THE STAR FORMATION PROPERTIES OF VOID GALAXIES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moorman, Crystal M.; Moreno, Jackeline; White, Amanda

    2016-11-10

    We measure the star formation properties of two large samples of galaxies from the SDSS in large-scale cosmic voids on timescales of 10 and 100 Myr, using H α emission line strengths and GALEX FUV fluxes, respectively. The first sample consists of 109,818 optically selected galaxies. We find that void galaxies in this sample have higher specific star formation rates (SSFRs; star formation rates per unit stellar mass) than similar stellar mass galaxies in denser regions. The second sample is a subset of the optically selected sample containing 8070 galaxies with reliable H i detections from ALFALFA. For the fullmore » H i detected sample, SSFRs do not vary systematically with large-scale environment. However, investigating only the H i detected dwarf galaxies reveals a trend toward higher SSFRs in voids. Furthermore, we estimate the star formation rate per unit H i mass (known as the star formation efficiency; SFE) of a galaxy, as a function of environment. For the overall H i detected population, we notice no environmental dependence. Limiting the sample to dwarf galaxies still does not reveal a statistically significant difference between SFEs in voids versus walls. These results suggest that void environments, on average, provide a nurturing environment for dwarf galaxy evolution allowing for higher specific star formation rates while forming stars with similar efficiencies to those in walls.« less

  19. Mutations in HPSE2 cause urofacial syndrome.

    PubMed

    Daly, Sarah B; Urquhart, Jill E; Hilton, Emma; McKenzie, Edward A; Kammerer, Richard A; Lewis, Malcolm; Kerr, Bronwyn; Stuart, Helen; Donnai, Dian; Long, David A; Burgu, Berk; Aydogdu, Ozgu; Derbent, Murat; Garcia-Minaur, Sixto; Reardon, Willie; Gener, Blanca; Shalev, Stavit; Smith, Rupert; Woolf, Adrian S; Black, Graeme C; Newman, William G

    2010-06-11

    Urinary voiding dysfunction in childhood, manifesting as incontinence, dysuria, and urinary frequency, is a common condition. Urofacial syndrome (UFS) is a rare autosomal recessive disease characterized by facial grimacing when attempting to smile and failure of the urinary bladder to void completely despite a lack of anatomical bladder outflow obstruction or overt neurological damage. UFS individuals often have reflux of infected urine from the bladder to the upper renal tract, with a risk of kidney damage and renal failure. Whole-genome SNP mapping in one affected individual defined an autozygous region of 16 Mb on chromosome 10q23-q24, within which a 10 kb deletion encompassing exons 8 and 9 of HPSE2 was identified. Homozygous exonic deletions, nonsense mutations, and frameshift mutations in five further unrelated families confirmed HPSE2 as the causative gene for UFS. Mutations were not identified in four additional UFS patients, indicating genetic heterogeneity. We show that HPSE2 is expressed in the fetal and adult central nervous system, where it might be implicated in controlling facial expression and urinary voiding, and also in bladder smooth muscle, consistent with a role in renal tract morphology and function. Our findings have broader implications for understanding the genetic basis of lower renal tract malformations and voiding dysfunction.

  20. Mutations in HPSE2 Cause Urofacial Syndrome

    PubMed Central

    Daly, Sarah B.; Urquhart, Jill E.; Hilton, Emma; McKenzie, Edward A.; Kammerer, Richard A.; Lewis, Malcolm; Kerr, Bronwyn; Stuart, Helen; Donnai, Dian; Long, David A.; Burgu, Berk; Aydogdu, Ozgu; Derbent, Murat; Garcia-Minaur, Sixto; Reardon, Willie; Gener, Blanca; Shalev, Stavit; Smith, Rupert; Woolf, Adrian S.; Black, Graeme C.; Newman, William G.

    2010-01-01

    Urinary voiding dysfunction in childhood, manifesting as incontinence, dysuria, and urinary frequency, is a common condition. Urofacial syndrome (UFS) is a rare autosomal recessive disease characterized by facial grimacing when attempting to smile and failure of the urinary bladder to void completely despite a lack of anatomical bladder outflow obstruction or overt neurological damage. UFS individuals often have reflux of infected urine from the bladder to the upper renal tract, with a risk of kidney damage and renal failure. Whole-genome SNP mapping in one affected individual defined an autozygous region of 16 Mb on chromosome 10q23-q24, within which a 10 kb deletion encompassing exons 8 and 9 of HPSE2 was identified. Homozygous exonic deletions, nonsense mutations, and frameshift mutations in five further unrelated families confirmed HPSE2 as the causative gene for UFS. Mutations were not identified in four additional UFS patients, indicating genetic heterogeneity. We show that HPSE2 is expressed in the fetal and adult central nervous system, where it might be implicated in controlling facial expression and urinary voiding, and also in bladder smooth muscle, consistent with a role in renal tract morphology and function. Our findings have broader implications for understanding the genetic basis of lower renal tract malformations and voiding dysfunction. PMID:20560210

  1. Voids and constraints on nonlinear clustering of galaxies

    NASA Technical Reports Server (NTRS)

    Vogeley, Michael S.; Geller, Margaret J.; Park, Changbom; Huchra, John P.

    1994-01-01

    Void statistics of the galaxy distribution in the Center for Astrophysics Redshift Survey provide strong constraints on galaxy clustering in the nonlinear regime, i.e., on scales R equal to or less than 10/h Mpc. Computation of high-order moments of the galaxy distribution requires a sample that (1) densely traces the large-scale structure and (2) covers sufficient volume to obtain good statistics. The CfA redshift survey densely samples structure on scales equal to or less than 10/h Mpc and has sufficient depth and angular coverage to approach a fair sample on these scales. In the nonlinear regime, the void probability function (VPF) for CfA samples exhibits apparent agreement with hierarchical scaling (such scaling implies that the N-point correlation functions for N greater than 2 depend only on pairwise products of the two-point function xi(r)) However, simulations of cosmological models show that this scaling in redshift space does not necessarily imply such scaling in real space, even in the nonlinear regime; peculiar velocities cause distortions which can yield erroneous agreement with hierarchical scaling. The underdensity probability measures the frequency of 'voids' with density rho less than 0.2 -/rho. This statistic reveals a paucity of very bright galaxies (L greater than L asterisk) in the 'voids.' Underdensities are equal to or greater than 2 sigma more frequent in bright galaxy samples than in samples that include fainter galaxies. Comparison of void statistics of CfA samples with simulations of a range of cosmological models favors models with Gaussian primordial fluctuations and Cold Dark Matter (CDM)-like initial power spectra. Biased models tend to produce voids that are too empty. We also compare these data with three specific models of the Cold Dark Matter cosmogony: an unbiased, open universe CDM model (omega = 0.4, h = 0.5) provides a good match to the VPF of the CfA samples. Biasing of the galaxy distribution in the 'standard' CDM model (omega = 1, b = 1.5; see below for definitions) and nonzero cosmological constant CDM model (omega = 0.4, h = 0.6 lambda(sub 0) = 0.6, b = 1.3) produce voids that are too empty. All three simulations match the observed VPF and underdensity probability for samples of very bright (M less than M asterisk = -19.2) galaxies, but produce voids that are too empty when compared with samples that include fainter galaxies.

  2. Neural Mechanisms Underlying Lower Urinary Tract Dysfunction

    PubMed Central

    Ogawa, Teruyuki; Miyazato, Minoru; Kitta, Takeya; Furuta, Akira; Chancellor, Michael B.; Tyagi, Pradeep

    2014-01-01

    This article summarizes anatomical, neurophysiological, and pharmacological studies in humans and animals to provide insights into the neural circuitry and neurotransmitter mechanisms controlling the lower urinary tract and alterations in these mechanisms in lower urinary tract dysfunction. The functions of the lower urinary tract, to store and periodically release urine, are dependent on the activity of smooth and striated muscles in the bladder, urethra, and external urethral sphincter. During urine storage, the outlet is closed and the bladder smooth muscle is quiescent. When bladder volume reaches the micturition threshold, activation of a micturition center in the dorsolateral pons (the pontine micturition center) induces a bladder contraction and a reciprocal relaxation of the urethra, leading to bladder emptying. During voiding, sacral parasympathetic (pelvic) nerves provide an excitatory input (cholinergic and purinergic) to the bladder and inhibitory input (nitrergic) to the urethra. These peripheral systems are integrated by excitatory and inhibitory regulation at the levels of the spinal cord and the brain. Therefore, injury or diseases of the nervous system, as well as disorders of the peripheral organs, can produce lower urinary tract dysfunction, leading to lower urinary tract symptoms, including both storage and voiding symptoms, and pelvic pain. Neuroplasticity underlying pathological changes in lower urinary tract function is discussed. PMID:24578802

  3. Content validity of the Benign Prostatic Hyperplasia Impact Index (BII); a measure of how urinary trouble and problems associated with BPH may impact the patient.

    PubMed

    Kingery, L; Martin, M L; Naegeli, A N; Khan, S; Viktrup, L

    2012-09-01

    The objective of this qualitative interview study was to assess the content validity of the Benign Prostatic Hyperplasia Impact Index (BII) in a sample of men with signs and symptoms of Benign Prostatic Obstruction believed to be caused by benign prostatic hyperplasia (BPH lower urinary tract symptoms/BPH-LUTS) using concept elicitation (CE) and cognitive interviewing (CI) methods. Fifty men with BPH-LUTS participated in the study; 27 completed CE interviews and 23 completed cognitive interviews. Patient's average age was 69 years with a mean duration of BPH-LUTS of 6.5 years. IPSS scores ranged from 8 to 33 (higher scores indicating greater symptom severity). Overall, the most frequent symptoms (prevalence of ≥ 75%) reported spontaneously or after further explanation were awakening from sleep, increased daytime voiding (frequency), urgent desire to void (urgency), slow stream, and feeling of incomplete bladder emptying. Symptoms primarily recognized in response to follow up probe questions with a prevalence of ≥ 40% included terminal dribble, splitting of urinary stream, intermittent stream, straining and post-micturition dribble. Especially bothersome [> 5 on the numerical rating scale (NRS) of 0-10] and frequent symptoms included urgency and awakening at night to void. Discomfort or pain while urinating and post-micturition dribble were equally bothersome though less frequent. Five BPH symptom-related impact themes were identified: coping, daily responsibilities, emotion, lifestyle and relationships, and sleep. The BII was found to be easily understood, does capture clinically relevant BPH impacts related to urinary trouble and problems, and does capture most of the important symptom-related impacts as described by participants in this study. © 2012 Blackwell Publishing Ltd.

  4. Real-time measurement of oxyhemoglobin concentration changes in the frontal micturition area: an fNIRS study.

    PubMed

    Sakakibara, Ryuji; Tsunoyama, Kuniko; Takahashi, Osamu; Sugiyama, Megumi; Kishi, Masahiko; Ogawa, Emina; Uchiyama, Tomoyuki; Yamamoto, Tatsuya; Yamanishi, Tomonori; Awa, Yusuke; Yamaguchi, Chiharu

    2010-06-01

    To explore brain activity in the frontal micturition area during natural bladder behavior. Five control subjects (one man and four women; mean age 61 years [38-70]) and four subjects with detrusor overactivity (all men; mean age 55 years [33-65]) were enrolled in the study. We performed real-time measurements of oxyhemoglobin concentration (oxy-Hb) changes in the frontal micturition area using functional near-infrared spectroscopy (fNIRS) in response to quasi-natural, continuous bladder filling, and voiding in a sitting position. In the control group the following results were obtained: (1) a slight increase of oxy-Hb before first sensation occurred, (2) there was a continuous increase of oxy-Hb during bladder filling to the point just after voiding began, (3) there was a continuous decrease of oxy-Hb after voiding, (4) in subjects who were unable to urinate, oxy-Hb also decreased after attempting to void, and (5) the area activated was the bilateral lateral prefrontal area, particularly Brodmann's areas 8, 10, and 46. In the detrusor overactivity group, (6) an increase of oxy-Hb before first sensation was rare and frontal cortical activation was weak, (7) at the moment detrusor overactivity appeared, fNIRS brain activity in the frontal cortex did not change significantly; and otherwise the results were almost the same as those in the control group. This study shows that the frontal micturition area is activated during natural bladder filling and voiding using fNIRS. (c) 2010 Wiley-Liss, Inc.

  5. Indirect-response modeling of desmopressin at different levels of hydration.

    PubMed

    Callréus, T; Odeberg, J; Lundin, S; Höglund, P

    1999-10-01

    The objective of the present study was to investigate the pharmacokinetics (PK) and pharmacodynamics (PD) of desmopressin in healthy male subjects at different levels of overhydration. Also, we examined if an indirect-response model could be related to renal physiology and the pharmacological action of desmopressin. Eight healthy male subjects participated in this open, randomized crossover study with three periods. Each subject was orally water loaded (0 to 20 ml.kg-1 body weight) on 3 study days in order to achieve three different levels of hydration. After the initial water load, urine was voided every 15 min and the volumes were measured. To ensure continuous overhydration the subjects replaced their fluid loss with drinking-water. When a steady-state diuresis was achieved after approximately 2 hr, 0.396 microgram of desmopressin was administered intravenously as a bolus injection. Blood was sampled and urine was collected at intervals throughout the study day (10 hr). An indirect-response model, where desmopressin was assumed to inhibit the elimination of response, was fit to the urine osmolarity data. There were no statistically significant effects of different levels of hydration, as expressed by urine flow rate at baseline, on the estimates of the PK and PD model parameters. The calculated terminal half-lives of elimination (t1/2 beta) ranged between 2.76 and 8.37 hr with an overall mean of 4.36 hr. The overall means of plasma clearance and the volumes of distribution of the central compartment (Vc) and at steady state (Vss) were estimated to be 1.34 (SD 0.35) ml.min-1.kg-1, 151 (SD28) ml.kg-1, and 386 (SD 63) ml.kg-1, respectively. High urine flow rate, indicating overhydration, produced a diluted urine and thus a low osmolarity at baseline (R0). The effect of the urine flow rate on the urine osmolarity at baseline was highly significant (p < 0.0001). The mean values for IC50 and the sigmodicity factor (gamma) were 3.7 (SD 1.2) pg ml-1 and 13.0 (SD 3.5), respectively. In most cases when there was a high urine flow rate at baseline, the model and the estimated PD parameters could be related to the pharmacological action of desmopressin and renal physiology. Thus, the indirect-response model used in this study offers a mechanistic approach of modeling the effect of desmopressin in overhydrated subjects.

  6. The urodynamic evaluation of neuromodulation in patients with voiding dysfunction.

    PubMed

    Everaert, K; Plancke, H; Lefevere, F; Oosterlinck, W

    1997-05-01

    To determine which patients with voiding dysfunction might be suitable for treatment with neuromodulation, using urodynamics to obtain an objective measure of improvement and to illustrate the effect of neuromodulation on voiding dysfunction. Patients were selected for implantation of a neuroprosthesis using a urodynamic evaluation before and during subchronic stimulation; 27 such patients (four men and 23 women, mean age 33 years, SD 15) were evaluated. Of the 27 patients, the 17 who responded well to neuromodulation all had hypocontractile detrusors and sphincter hypertonicity; sphincter relaxation during micturition was impaired. The urodynamic evaluation showed that these patients were not obstructed. Of 10 patients with spastic pelvic floor syndrome, nine responded well to the treatment. Those not responding to neuromodulation had mainly acontractile detrusors. The ideal candidates for neuromodulation are those patients with a spastic pelvic floor syndrome or with a hypocontractile detrusor, in combination with sphincter instability, and impaired sphincter relaxation. An increase of bladder contractility, enhancement of sphincter relaxation and decrease in bladder capacity and residual urine are the most important features of the response.

  7. Development of Personalized Urination Recognition Technology Using Smart Bands.

    PubMed

    Eun, Sung-Jong; Whangbo, Taeg-Keun; Park, Dong Kyun; Kim, Khae-Hawn

    2017-04-01

    This study collected and analyzed activity data sensed through smart bands worn by patients in order to resolve the clinical issues posed by using voiding charts. By developing a smart band-based algorithm for recognizing urination activity in patients, this study aimed to explore the feasibility of urination monitoring systems. This study aimed to develop an algorithm that recognizes urination based on a patient's posture and changes in posture. Motion data was obtained from a smart band on the arm. An algorithm that recognizes the 3 stages of urination (forward movement, urination, backward movement) was developed based on data collected from a 3-axis accelerometer and from tilt angle data. Real-time data were acquired from the smart band, and for data corresponding to a certain duration, the absolute value of the signals was calculated and then compared with the set threshold value to determine the occurrence of vibration signals. In feature extraction, the most essential information describing each pattern was identified after analyzing the characteristics of the data. The results of the feature extraction process were sorted using a classifier to detect urination. An experiment was carried out to assess the performance of the recognition technology proposed in this study. The final accuracy of the algorithm was calculated based on clinical guidelines for urologists. The experiment showed a high average accuracy of 90.4%, proving the robustness of the proposed algorithm. The proposed urination recognition technology draws on acceleration data and tilt angle data collected via a smart band; these data were then analyzed using a classifier after comparative analyses with standardized feature patterns.

  8. Smoking and prevalence of nocturia in Japanese patients with type 2 diabetes mellitus: a post-hoc analysis of The Dogo Study.

    PubMed

    Furukawa, Shinya; Sakai, Takenori; Niiya, Tetsuji; Miyaoka, Hiroaki; Miyake, Teruki; Yamamoto, Shin; Kanzaki, Sayaka; Maruyama, Koutatsu; Tanaka, Keiko; Ueda, Teruhisa; Senba, Hidenori; Torisu, Masamoto; Minami, Hisaka; Onji, Morikazu; Tanigawa, Takeshi; Matsuura, Bunzo; Hiasa, Yoichi; Miyake, Yoshihiro

    2017-06-01

    No evidence exists regarding the association between smoking status and nocturia among patients with type 2 diabetes mellitus. We evaluated this association among Japanese patients with type 2 diabetes mellitus by post-hoc analysis. Study subjects were 817 Japanese patients with type 2 diabetes mellitus. Study subjects were considered to have nocturia if they answered "once or more" to the question: "Within one week, how many times do you typically wake up to urinate from sleeping at night until waking in the morning?" We used the following three outcomes: (1) nocturia was ≥1 voids per night; (2) moderate nocturia was ≥2 voids per night; and (3) severe nocturia was ≥3 voids per night. Adjustments were made for age, sex, body mass index, hypertension, dyslipidemia, stroke, glycated hemoglobin, current drinking, use of anti-hypertensive agent, use of insulin, use of oral anti-hyperglycemic agent, and diabetic retinopathy. The prevalence values of one void per night, two voids per night, and three or more voids per night were 39.5%, 27.1%, and 14.8%, respectively. Current smoking was independently inversely associated with severe nocturia compared with never or former smoking; the adjusted PR was 0.47 (95%CI: 0.25-0.89). Among the 443 patients who had ever smoked, compared with former smoking, current smoking was independently inversely related to severe nocturia; the adjusted PR was 0.44 (95%CI: 0.24-0.82). In Japanese patients with type 2 diabetes mellitus, current smoking may be independently inversely associated with severe nocturia. © 2016 Wiley Periodicals, Inc.

  9. Work Capacity of the Bladder During Voiding: A Novel Method to Evaluate Bladder Contractile Function and Bladder Outlet Obstruction

    PubMed Central

    Liu, Ning; Man, Li-Bo; He, Feng; Huang, Guang-Lin; Zhou, Ning; Zhu, Xiao-Fei

    2015-01-01

    Background: Work in voiding (WIV) of the bladder may be used to evaluate bladder status throughout urination rather than at a single time point. Few studies, however, have assessed WIV owing to the complexity of its calculations. We have developed a method of calculating work capacity of the bladder while voiding and analyzed the associations of bladder work parameters with bladder contractile function and bladder outlet obstruction (BOO). Methods: The study retrospectively evaluated 160 men and 23 women, aged >40 years and with a detrusor pressure at maximal flow rate (Pdet Qmax) of ≥40 cmH2O in men, who underwent urodynamic testing. The bladder power integration method was used to calculate WIV; WIV per second (WIV/t) and WIV per liter of urine voided (WIV/v) were also calculated. In men, the relationships between these work capacity parameters and Pdet Qmax and Abrams-Griffiths (AG) number were determined using linear-by-linear association tests, and relationships between work capacity parameters and BOO grade were investigated using Spearman's association test. Results: The mean WIV was 1.15 ± 0.78 J and 1.30 ± 0.88 J, mean WIV/t was 22.95 ± 14.45 mW and 23.78 ± 17.02 mW, and mean WIV/v was 5.59 ± 2.32 J/L and 2.83 ± 1.87 J/L in men and women, respectively. In men, WIV/v showed significant positive associations with Pdet Qmax (r = 0.845, P = 0.000), AG number (r = 0.814, P = 0.000), and Schafer class (r = 0.726, P = 0.000). Conversely, WIV and WIV/t showed no associations with Pdet Qmax or AG number. In patients with BOO (Schafer class > II), WIV/v correlated positively with increasing BOO grade. Conclusions: WIV can be calculated from simple urodynamic parameters using the bladder power integration method. WIV/v may be a marker of BOO grade, and the bladder contractile function can be evaluated by WIV and WIV/t. PMID:26668148

  10. The Shape of the Urine Stream — From Biophysics to Diagnostics

    PubMed Central

    Wheeler, Andrew P. S.; Morad, Samir; Buchholz, Noor; Knight, Martin M.

    2012-01-01

    We develop a new computational model of capillary-waves in free-jet flows, and apply this to the problem of urological diagnosis in this first ever study of the biophysics behind the characteristic shape of the urine stream as it exits the urethral meatus. The computational fluid dynamics model is used to determine the shape of a liquid jet issuing from a non-axisymmetric orifice as it deforms under the action of surface tension. The computational results are verified with experimental modelling of the urine stream. We find that the shape of the stream can be used as an indicator of both the flow rate and orifice geometry. We performed volunteer trials which showed these fundamental correlations are also observed in vivo for male healthy volunteers and patients undergoing treatment for low flow rate. For healthy volunteers, self estimation of the flow shape provided an accurate estimation of peak flow rate (). However for the patients, the relationship between shape and flow rate suggested poor meatal opening during voiding. The results show that self measurement of the shape of the urine stream can be a useful diagnostic tool for medical practitioners since it provides a non-invasive method of measuring urine flow rate and urethral dilation. PMID:23091609

  11. [Evaluation and clinical management of urination disorders in 1,025 patients in a geriatric department].

    PubMed

    Abrahamik, A; Leblond, J B; Perilliat, I; Henry, O; Loison, M; De Madet, M; Cotteret, R

    1993-01-01

    Evaluation of voluntary urination and measurement of the post-voiding residue enabled the identification of 6 groups among 1,025 patients 83 +/- 7 years old: 400 normal patients (N); 97 with retention but without incontinence (R); 133 incontinent without retention (I); 50 incontinent with retention (IR); 236 who failed to urinate voluntarily (MO); 109 with indwelling catheters (SAD). Incontinence and indwelling catheters were more common in women; men more frequently failed to urinate voluntarily (p < 0.01). The IR and SAD groups had more urinary infections (p < 0.01) and included more invalids (p < 0.001). The MO and SAD groups had more demented members (p < 0.001) and a higher death rate (p < 0.001). Management consisted of a 48-hour diary of urinations (R and IR groups), scheduled micturitions (I and MO groups) and treatment of urinary infections. Evaluation of bladder sphincter function (n = 291) showed that bladder hypoesthesia was prevalent in groups R and IR and that bladder hyperactivity was predominant in groups I, MO and SAD. Among the 314 patients discharged from the hospital, 181 were reevaluated: good results were obtained for 43% of the initially incontinent and for 53% of those with retention. The indwelling catheters were removed from 82% of the SAD group.

  12. The Metallicity of Void Dwarf Galaxies

    NASA Astrophysics Data System (ADS)

    Kreckel, K.; Croxall, K.; Groves, B.; van de Weygaert, R.; Pogge, R. W.

    2015-01-01

    The current ΛCDM cosmological model predicts that galaxy evolution proceeds more slowly in lower density environments, suggesting that voids are a prime location to search for relatively pristine galaxies that are representative of the building blocks of early massive galaxies. To test the assumption that void galaxies are more pristine, we compare the evolutionary properties of a sample of dwarf galaxies selected specifically to lie in voids with a sample of similar isolated dwarf galaxies in average density environments. We measure gas-phase oxygen abundances and gas fractions for eight dwarf galaxies (Mr > -16.2), carefully selected to reside within the lowest density environments of seven voids, and apply the same calibrations to existing samples of isolated dwarf galaxies. We find no significant difference between these void dwarf galaxies and the isolated dwarf galaxies, suggesting that dwarf galaxy chemical evolution proceeds independent of the large-scale environment. While this sample is too small to draw strong conclusions, it suggests that external gas accretion is playing a limited role in the chemical evolution of these systems, and that this evolution is instead dominated mainly by the internal secular processes that are linking the simultaneous growth and enrichment of these galaxies.

  13. 6-sulfatoxymelatonin levels in pregnant women during workplace and nonworkplace stresses: a potential biologic marker of sympathetic activity.

    PubMed

    Katz, V L; Ekstrom, R D; Mason, G A; Golden, R N

    1995-07-01

    Melatonin production is regulated by both catecholamines and sympathetic activity. Urine levels of the major metabolite of melatonin, 6-sulfatoxymelatonin, correlate well with serum melatonin levels and have been used to evaluate sympathetic output. We tested the hypothesis that urinary levels of 6-sulfatoxymelatonin would reflect the change in adrenergic activity on working days compared with nonworking days during pregnancy. Twenty-three healthy pregnant women, employed in a variety of occupations, including physicians, nurses, secretaries, salespeople, and laboratory workers were recruited from the clinics of the University of North Carolina School of Medicine. We measured 6-sulfatoxymelatonin levels in first morning voids and for the subsequent 10 hours at 24, 28, 32, and 36 weeks' gestation. Urine was collected in sets during working days and during nonworking days. 6-Sulfatoxymelatonin was measured by radioimmunoassay. In 11 women we also measured urine catecholamines by high-performance liquid chromatography. Levels of 6-sulfatoxymelatonin output did not change across gestation, although they tended to drift down as pregnancy progressed. Median levels at first morning void were 6.3 micrograms on workdays and 4.6 micrograms on nonworkdays. Although all values were skewed toward work being greater than nonwork, there were large interindividual variations. We therefore compared subjects against themselves and compared work levels for each subject to the corresponding gestational age-matched nonwork value. Among the 23 women, median 6-sulfatoxymelatonin levels were 81% greater during work than nonwork (p < 0.0002) when first morning collections were compared. Daytime urinary excretion of 6-sulfatoxymelatonin on workdays was 38% (p < 0.005) greater than during nonworkdays.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Nocturia: current status and future perspectives.

    PubMed

    Van Kerrebroeck, Philip

    2011-10-01

    Nocturia is a bothersome and highly prevalent condition characterized by the need to wake to void at night. Nocturia is equally common in men and women, and although its prevalence increases with age, a significant proportion of younger people are also affected. Nocturia leads to fragmentation of sleep and consequently to a serious decline in daytime functioning and in quality of life and health. Its impact should not be underestimated by clinicians and therefore a review on nocturia is timely and relevant. Traditionally, nocturia is regarded as a symptom of benign prostatic enlargement and/or overactive bladder syndrome, with treatment therefore directed toward increasing the capacity of the bladder to hold urine. Such treatments have proven ineffective in many patients because nocturnal polyuria, an overproduction of urine at night, has been found to be present in the majority of patients. Nocturia can be attributed to some underlying pathological factors but it can also be a distinct clinical entity with specific pathogenesis. Frequency-volume charts are recommended for routine use in clinical practice, to determine whether nocturia is a result of excessive urine production at night, or of small voided volumes due to bladder problems, or a combination of these factors. Desmopressin, a synthetic analogue of the antidiuretic hormone, should be considered in patients with nocturia where nocturnal polyuria is present. Contrary to popular and medical misconception nocturia is an important condition leading to general morbidity and with serious impact on overall quality of life and health. We advise clinicians to pay attention to nocturia and diagnostics should be offered. Treatment modalities are available and have to be discussed with the patient. (C) 2011 Lippincott Williams & Wilkins, Inc.

  15. Evaluation of the urinary microbiota of women with uncomplicated stress urinary incontinence.

    PubMed

    Thomas-White, Krystal J; Kliethermes, Stephanie; Rickey, Leslie; Lukacz, Emily S; Richter, Holly E; Moalli, Pamela; Zimmern, Philippe; Norton, Peggy; Kusek, John W; Wolfe, Alan J; Brubaker, Linda

    2017-01-01

    Female urinary microbiota are associated with urgency urinary incontinence and response to medication. The urinary microbiota of women with stress urinary incontinence has not been described. We sought to study the cross-sectional relationships between urinary microbiota features and demographic and clinical characteristics of women undergoing stress urinary incontinence surgery. Preoperative urine specimens were collected from women without urinary tract infection and were available from 197 women (174 voided, 23 catheterized) enrolled in a multicenter prospective randomized trial, the Value of Urodynamic Evaluation study. Demographic and clinical variables were obtained including stress and urgency urinary incontinence symptoms, menopausal status, and hormone use. The bacterial composition of the urine was qualitatively assessed by sequencing the bacterial 16S ribosomal RNA gene. Phylogenetic relatedness and microbial alpha diversity were compared to demographics and symptoms using generalized estimating equation models. The majority of 197 urine samples (86%) had detectable bacterial DNA. Bacterial diversity was significantly associated with higher body mass index (P = .02); increased Medical, Epidemiologic, and Social Aspects of Aging urge index score (P = .04); and hormonal status (P < .001). No associations were detected with stress urinary incontinence symptoms. Increased diversity was also associated with a concomitant lower frequency of Lactobacillus in hormone-negative women. Women undergoing stress urinary incontinence surgery have detectable urinary microbiota. This cross-sectional analysis revealed that increased diversity of the microbiota was associated with urgency urinary incontinence symptoms, hormonal status, and body mass index. In contrast, the female urinary microbiota were not associated with stress urinary incontinence symptoms. Published by Elsevier Inc.

  16. Age, gender, and voided volume dependency of peak urinary flow rate and uroflowmetry nomogram in the Indian population

    PubMed Central

    Kumar, Vikash; Dhabalia, Jayesh V.; Nelivigi, Girish G.; Punia, Mahendra S.; Suryavanshi, Manav

    2009-01-01

    Objectives: The objective of this study was measurement of urine flow parameters by a non invasive urodynamic test. Variation of flow rates based on voided volume, age, and gender are described. Different nomograms are available for different populations and racial differences of urethral physiology are described. Currently, there has been no study from the Indian population on uroflow parameters. So the purpose of this study was to establish normal reference ranges of maximum and average flow rates, to see the influence of age, gender, and voided volume on flow rates, and to chart these values in the form of a nomogram. Methods: We evaluated 1,011 uroflowmetry tests in different age groups in a healthy population (healthy relatives of our patients) 16-50 year old males, >50 year old males, 5-15 year old children, and >15 year pre-menopausal and post-menopausal females. The uroflowmetry was done using the gravitimetric method. Flow chart parameters were analyzed and statistical calculations were used for drawing uroflow nomograms. Results: Qmax values in adult males were significantly higher than in the elderly and Qmax values in young females were significantly higher than in young males. Qmax values in males increased with age until 15 years old; followed by a slow decline until reaching 50 years old followed by a rapid decline after 50 years old even after correcting voided volume. Qmax values in females increased with age until they reached age 15 followed by decline in flow rate until a pre-menopausal age followed by no significant decline in post-menopausal females. Qmax values increased with voided volume until 700 cc followed by a plateau and decline. Conclusions: Qmax values more significantly correlated with age and voided volume than Qavg. Nomograms were drawn in centile form to provide normal reference ranges. Qmax values in our population were lower than described in literature. Patients with voided volume up to 50 ml could be evaluated with a nomogram. PMID:19955668

  17. Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing

    PubMed Central

    Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre

    2016-01-01

    The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated. PMID:27196899

  18. Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing.

    PubMed

    Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre

    2016-05-17

    The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated.

  19. NEW COLUMN SEPARATION METHOD FOR EMERGENCY URINE SAMPLES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, S; Brian Culligan, B

    2007-08-28

    The Savannah River Site Environmental Bioassay Lab participated in the 2007 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2007. A new rapid column separation method was applied directly to the NRIP 2007 emergency urine samples, with only minimal sample preparation to reduce preparation time. Calcium phosphate precipitation, previously used to pre-concentrate actinides and Sr-90 in NRIP 2006 urine and water samples, was not used for the NRIP 2007 urine samples. Instead, the raw urine was acidified and passed directly through the stacked resin columns (TEVA+TRU+SR Resins) to separate the actinides andmore » strontium from the NRIP urine samples more quickly. This improvement reduced sample preparation time for the NRIP 2007 emergency urine analyses significantly. This approach works well for small volume urine samples expected during an emergency response event. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and strontium-90 analyses for NRIP 2007 urine samples.« less

  20. Log-Normal Distribution of Cosmic Voids in Simulations and Mocks

    NASA Astrophysics Data System (ADS)

    Russell, E.; Pycke, J.-R.

    2017-01-01

    Following up on previous studies, we complete here a full analysis of the void size distributions of the Cosmic Void Catalog based on three different simulation and mock catalogs: dark matter (DM), haloes, and galaxies. Based on this analysis, we attempt to answer two questions: Is a three-parameter log-normal distribution a good candidate to satisfy the void size distributions obtained from different types of environments? Is there a direct relation between the shape parameters of the void size distribution and the environmental effects? In an attempt to answer these questions, we find here that all void size distributions of these data samples satisfy the three-parameter log-normal distribution whether the environment is dominated by DM, haloes, or galaxies. In addition, the shape parameters of the three-parameter log-normal void size distribution seem highly affected by environment, particularly existing substructures. Therefore, we show two quantitative relations given by linear equations between the skewness and the maximum tree depth, and between the variance of the void size distribution and the maximum tree depth, directly from the simulated data. In addition to this, we find that the percentage of voids with nonzero central density in the data sets has a critical importance. If the number of voids with nonzero central density reaches ≥3.84% in a simulation/mock sample, then a second population is observed in the void size distributions. This second population emerges as a second peak in the log-normal void size distribution at larger radius.

  1. Fuzzy Reasoning to More Accurately Determine Void Areas on Optical Micrographs of Composite Structures

    NASA Technical Reports Server (NTRS)

    Dominquez, Jesus A.; Tate, Lanetra C.; Wright, M. Clara; Caraccio, Anne

    2013-01-01

    Accomplishing the best-performing composite matrix (resin) requires that not only the processing method but also the cure cycle generate low-void-content structures. If voids are present, the performance of the composite matrix will be significantly reduced. This is usually noticed by significant reductions in matrix-dominated properties, such as compression and shear strength. Voids in composite materials are areas that are absent of the composite components: matrix and fibers. The characteristics of the voids and their accurate estimation are critical to determine for high performance composite structures. One widely used method of performing void analysis on a composite structure sample is acquiring optical micrographs or Scanning Electron Microscope (SEM) images of lateral sides of the sample and retrieving the void areas within the micrographs/images using an image analysis technique. Segmentation for the retrieval and subsequent computation of void areas within the micrographs/images is challenging as the gray-scaled values of the void areas are close to the gray-scaled values of the matrix leading to the need of manually performing the segmentation based on the histogram of the micrographs/images to retrieve the void areas. The use of an algorithm developed by NASA and based on Fuzzy Reasoning (FR) proved to overcome the difficulty of suitably differentiate void and matrix image areas with similar gray-scaled values leading not only to a more accurate estimation of void areas on composite matrix micrographs but also to a faster void analysis process as the algorithm is fully autonomous.

  2. Urinary tract infections in children: EAU/ESPU guidelines.

    PubMed

    Stein, Raimund; Dogan, Hasan S; Hoebeke, Piet; Kočvara, Radim; Nijman, Rien J M; Radmayr, Christian; Tekgül, Serdar

    2015-03-01

    In 30% of children with urinary tract anomalies, urinary tract infection (UTI) can be the first sign. Failure to identify patients at risk can result in damage to the upper urinary tract. To provide recommendations for the diagnosis, treatment, and imaging of children presenting with UTI. The recommendations were developed after a review of the literature and a search of PubMed and Embase. A consensus decision was adopted when evidence was low. UTIs are classified according to site, episode, symptoms, and complicating factors. For acute treatment, site and severity are the most important. Urine sampling by suprapubic aspiration or catheterisation has a low contamination rate and confirms UTI. Using a plastic bag to collect urine, a UTI can only be excluded if the dipstick is negative for both leukocyte esterase and nitrite or microscopic analysis is negative for both pyuria and bacteriuria. A clean voided midstream urine sample after cleaning the external genitalia has good diagnostic accuracy in toilet-trained children. In children with febrile UTI, antibiotic treatment should be initiated as soon as possible to eradicate infection, prevent bacteraemia, improve outcome, and reduce the likelihood of renal involvement. Ultrasound of the urinary tract is advised to exclude obstructive uropathy. Depending on sex, age, and clinical presentation, vesicoureteral reflux should be excluded. Antibacterial prophylaxis is beneficial. In toilet-trained children, bladder and bowel dysfunction needs to be excluded. The level of evidence is high for the diagnosis of UTI and treatment in children but not for imaging to identify patients at risk for upper urinary tract damage. In these guidelines, we looked at the diagnosis, treatment, and imaging of children with urinary tract infection. There are strong recommendations on diagnosis and treatment; we also advise exclusion of obstructive uropathy within 24h and later vesicoureteral reflux, if indicated. Copyright © 2014 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  3. Effect of Sacral Neuromodulation on Outcome Measures and Urine Chemokines in Interstitial Cystitis/Painful Bladder Syndrome Patients.

    PubMed

    Peters, Kenneth M; Jayabalan, Nirmal; Bui, Don; Killinger, Kim; Chancellor, Michael; Tyagi, Pradeep

    2015-05-01

    Sacral neuromodulation (SNM) may improve interstitial cystitis/painful bladder syndrome (IC/BPS) symptoms of urinary frequency, urgency and perhaps even pain, but objective measures of improvement are lacking. We evaluated the potential for urinary chemokines to serve as measures of treatment response over time to SNM. Women with IC/BPS undergoing SNM consented for this study. Three-day bladder/pain diaries were collected at baseline and validated Interstitial Cystitis Symptom Problem Index (ICSPI) scores and mid-stream urine specimens were collected at baseline and at 24 weeks after successful implant. Collected urine was screened for infection by dipstick and analyzed for chemokines by luminex xMAP analysis. At baseline (n = 16), urine levels of CXCL-1 positively correlated with pain score (r = 0.63, P = 0.009), urgency (r = 0.61, P = 0.01), ICSPI (r = 0.43, P = 0.09) and daily voids (r = 0.44, P = 0.08). ICSPI and pain scores also positively correlated with sIL-1ra (r = 0.50, P = 0.04) and monocyte chemotactic protein-1 (MCP-1) or CCL2 positively correlated with daily voids (r = 0.45, P = 0.07) only. At 24 weeks, the median ICSPI index fell from 28 to 15 (n = 7, P = 0.008). Urine levels of sIL-1ra (633.8 ± 188.2 vs. 149.9 ± 41.62 pg/mL) and MCP-1 (448.3 ± 11.6 vs. 176.9 ± 46.16 pg/mL) and CCL5 (20.78 ± 4.09 vs. 11.21 ± 4.12 pg/mL) were also significantly reduced at the follow-up relative to baseline values (P = 0.04). Multivariable analysis of data revealed that sIL-1ra and MCP-1 together explained the majority of variance in data. Levels of CXCL-1, CXCL-10, interleukin (IL)-8, vascular endothelial growth factor (VEGF), platelet-derived growth factor (PDGF) were also reduced at 24 weeks, but differences were not significant. Concomitant decrease in urine levels of chemokines especially MCP-1 was associated with treatment response of SNM. These results support the role of chemokines as downstream effectors of neuromodulation response and could serve as potential non-invasive measures of treatment response. NCT01739946. © 2014 Wiley Publishing Asia Pty Ltd.

  4. Is sensory urgency part of the same spectrum of bladder dysfunction as detrusor overactivity?

    PubMed

    Haylen, Bernard T; Chetty, Naven; Logan, Vanessa; Schulz, Serena; Verity, Louise; Law, Matthew; Zhou, Jialun

    2007-02-01

    It has been suggested that the urogynecological diagnosis of sensory urgency is an early form of detrusor overactivity and may be just earlier in the spectrum of disease. The former term is generally defined as increased perceived bladder sensation during filling, a low first desire to void and low bladder capacity in the absence of recorded urinary tract infection (UTI) or detrusor overactivity. The aims of this study are to determine the prevalence and associations of sensory urgency in comparison with detrusor overactivity, and whether sensory urgency is shown to be in the same spectrum of bladder dysfunction as detrusor overactivity. Five hundred and ninety-two women attending for an initial urogynecological/urodynamic assessment took part in this prospective study. In addition to a full clinical assessment, all women underwent free uroflowmetry, residual urine volume measurement (by vaginal ultrasound) and multichannel filling and voiding cystometry. Data were separated into those having (1) sensory urgency or (2) detrusor overactivity. Apart from prevalence figures, comparative associations were sought for (3) age; (4) parity; (5) presenting symptoms; (6) presence of at least one (medically) documented UTI in the previous 12 months; (7) two or more (recurrent) documented UTIs in the previous 12 months; (8) prior hysterectomy; (9) prior continence surgery; (10) menopause; (11) menopause and HRT use; (12) sign of clinical stress leakage; (13) retroverted uterus; (14) anterior vaginal wall prolapse; (15) uterine prolapse; (16) posterior vaginal wall prolapse; (17) apical vaginal prolapse; (18, 19) maximum, average urine flow rate (MUFR, AUFR) centiles, Liverpool Nomograms; (20) median residual urine volume (RUV) in milliliters; (21, 22) voiding difficulty: VD1,VD2 (MUFR, AUFR under 10th centile Liverpool Nomogram and/or RUV >30 ml); (23) diagnosis of urodynamic stress incontinence and (24) diagnosis of uterine and/or vaginal prolapse (grade >0). The prevalence of sensory urgency was 13%. The only differences in the clinical and urodynamic profiles of it and detrusor overactivity were (1) significantly increased prevalence of the symptom of urge incontinence and (2) (by definition) abnormal detrusor contractions during filling cystometry in women with detrusor overactivity. Overall, sensory urgency and detrusor overactivity appear to be part of the same spectrum of bladder dysfunction.

  5. Holmium laser enucleation of the prostate combined with electrocautery resection: the mushroom technique.

    PubMed

    Hochreiter, Werner W; Thalmann, George N; Burkhard, Fiona C; Studer, Urs E

    2002-10-01

    The holmium laser allows bloodless enucleation of the prostate. A problem is how to remove a whole enucleated, free floating, large prostatic lobe from the bladder. A mechanical morcellator has been used to achieve tissue fragmentation but aspiration of and damage to the bladder wall are risks. Using the mushroom technique holmium laser enucleation and electrocautery resection can be combined without compromising the bloodless advantages of the laser procedure. We treated 156 patients with benign prostatic hyperplasia using a holmium laser with the mushroom technique. Preoperatively all patients were assessed using the International Prostate Symptom Score, maximum urine flow, ultrasound estimation of prostate volume and post-void residual urine, and pressure flow study. Laser enucleation of the prostatic lobes was performed at 66 W. Instead of releasing the lobes into the bladder they were left attached at the bladder neck by a narrow mushroom-like pedicle. At that point the vascular supply was almost completely interrupted and the lobes could easily be electroresected into small pieces without bleeding. Patients were followed 6, 12 and 24 months after the procedure. No patient had significant blood loss or signs of the transurethral resection syndrome. A total of 19 patients were treated while under oral anticoagulation without major bleeding problems. Complete followup was available on 125 patients. Median baseline International Prostate Symptom Score decreased from 20 to 3 at 6 months (p <0.05) and remained stable at 12 and 24 months. Median maximum urine flow increased from 8 to 20 ml. per second at 6, 12 and 24 months (p <0.05). Median baseline post-void residual urine decreased from 190 to 30 ml. at 6 months (p <0.05) and remained low at 20 and 30 ml. at 12 and 24 months, respectively. Urodynamic evaluation preoperatively and 6 months postoperatively was available in 83 cases. Relief of obstruction was documented with a statistically significant decrease in median detrusor pressure at maximum urine flow from 87 to 48 cm. water (p <0.05). Combining holmium laser enucleation and prostate electroresection with the mushroom technique is safe, efficient and bloodless surgical treatment for benign prostatic hyperplasia with sustained relief of obstruction. With this technique there is no need for additional devices, such as a mechanical tissue morcellator.

  6. Optimization of urinary dipstick pH: Are multiple dipstick pH readings reliably comparable to commercial 24-hour urinary pH?

    PubMed

    Abbott, Joel E; Miller, Daniel L; Shi, William; Wenzler, David; Elkhoury, Fuad F; Patel, Nishant D; Sur, Roger L

    2017-09-01

    Accurate measurement of pH is necessary to guide medical management of nephrolithiasis. Urinary dipsticks offer a convenient method to measure pH, but prior studies have only assessed the accuracy of a single, spot dipstick. Given the known diurnal variation in pH, a single dipstick pH is unlikely to reflect the average daily urinary pH. Our goal was to determine whether multiple dipstick pH readings would be reliably comparable to pH from a 24-hour urine analysis. Kidney stone patients undergoing a 24-hour urine collection were enrolled and took images of dipsticks from their first 3 voids concurrently with the 24-hour collection. Images were sent to and read by a study investigator. The individual and mean pH from the dipsticks were compared to the 24-hour urine pH and considered to be accurate if the dipstick readings were within 0.5 of the 24-hour urine pH. The Bland-Altman test of agreement was used to further compare dipstick pH relative to 24-hour urine pH. Fifty-nine percent of patients had mean urinary pH values within 0.5 pH units of their 24-hour urine pH. Bland-Altman analysis showed a mean difference between dipstick pH and 24-hour urine pH of -0.22, with an upper limit of agreement of 1.02 (95% confidence interval [CI], 0.45-1.59) and a lower limit of agreement of -1.47 (95% CI, -2.04 to -0.90). We concluded that urinary dipstick based pH measurement lacks the precision required to guide medical management of nephrolithiasis and physicians should use 24-hour urine analysis to base their metabolic therapy.

  7. Urine chemokines indicate pathogenic association of obesity with BPH/LUTS.

    PubMed

    Tyagi, Pradeep; Motley, Saundra S; Kashyap, Mahendra; Pore, Subrata; Gingrich, Jeffrey; Wang, Zhou; Yoshimura, Naoki; Fowke, Jay H

    2015-07-01

    High prevalence of lower urinary tract symptoms (LUTS) consistent with benign prostate hyperplasia (BPH) is associated with obesity and prostatic inflammation. Here, we investigated whether chemokines associated with obesity and prostatic inflammation can be measured in normally voided urine of BPH/LUTS patients to demonstrate the mechanistic association between obesity and BPH/LUTS. Frozen urine specimens of BPH/LUTS patients enrolled in the Nashville Men's Health Study were sent for blinded analysis to University of Pittsburgh. Thirty patients were blocked by their AUA-SI (>7 or ≤7) and prostatic enlargement (<40, 40-60, >60 cc). Clinical parameters including age, prostate size, and medications were derived from chart review. CXC chemokines (CXCL-1, CXCL-8, and CXCL-10), CC chemokines (CCL2 and CCL3), and sIL-1ra were measured in thawed urine using Luminex™ xMAP(®) technology and ELISA for NGF. Urinary CCL2 levels were several fold higher compared with the other six proteins, of which CCL3 was detectable in less than one-fourth of patients. Urine levels of sIL-1ra and CXCL-8 were significantly associated with increasing BMI and waist circumference in BPH patients. CXCL-8 showed a marginal association with overall AUA-SI scores, as well as obstructive (p = 0.08) symptom subscores. Prostate volume was inversely and marginally associated with urinary CXCL-10 (p = 0.09). Urine levels of CXCL-8, CXCL-10, and sIL-1ra were associated with varying degrees with LUTS severity, prostate size, and obesity, respectively. These findings in urine are consistent with past studies of chemokine levels from expressed prostatic secretions and demonstrate the potential of noninvasively measured chemokine in urine to objectively classify BPH/LUTS patients.

  8. Cosmic voids and void lensing in the Dark Energy Survey science verification data

    DOE PAGES

    Sánchez, C.; Clampitt, J.; Kovacs, A.; ...

    2016-10-26

    Galaxies and their dark matter halos populate a complicated filamentary network around large, nearly empty regions known as cosmic voids. Cosmic voids are usually identified in spectroscopic galaxy surveys, where 3D information about the large-scale structure of the Universe is available. Although an increasing amount of photometric data is being produced, its potential for void studies is limited since photometric redshifts induce line-of-sight position errors of ~50 Mpc/h or more that can render many voids undetectable. In this paper we present a new void finder designed for photometric surveys, validate it using simulations, and apply it to the high-quality photo-zmore » redMaGiC galaxy sample of the Dark Energy Survey Science Verification (DES-SV) data. The algorithm works by projecting galaxies into 2D slices and finding voids in the smoothed 2D galaxy density field of the slice. Fixing the line-of-sight size of the slices to be at least twice the photo- z scatter, the number of voids found in these projected slices of simulated spectroscopic and photometric galaxy catalogs is within 20% for all transverse void sizes, and indistinguishable for the largest voids of radius ~70 Mpc/h and larger. The positions, radii, and projected galaxy profiles of photometric voids also accurately match the spectroscopic void sample. Applying the algorithm to the DES-SV data in the redshift range 0.2 < z < 0.8 , we identify 87 voids with comoving radii spanning the range 18-120 Mpc/h, and carry out a stacked weak lensing measurement. With a significance of 4.4σ, the lensing measurement confirms the voids are truly underdense in the matter field and hence not a product of Poisson noise, tracer density effects or systematics in the data. In conclusion, it also demonstrates, for the first time in real data, the viability of void lensing studies in photometric surveys.« less

  9. A population-based study of the prevalence of HPV in three districts of Tamil Nadu, India.

    PubMed

    Sureshkumar, Belli T; Shanmughapriya, Santhanam; Das, Bhudev C; Natarajaseenivasan, Kalimuthusamy

    2015-04-01

    To evaluate the prevalence of HPV infection among women from three districts of Tamil Nadu (Erode, Salem, and Namakkal). Between January 27, 2007, and December 15, 2009, 1800 women aged 20-70years who had normal cervical cytology were enrolled into a cross-sectional study. Participants completed interviews and provided first void urine samples for assessment of HPV infection. Among 1699 eligible samples, 179 (10.5%) were HPV positive. HPV16 was the most common type (affecting 68 [4.0%] women), followed by HPV6 (58 [3.4%]). Among the 179 HPV-positive women, 71 (39.7%) were aged 36-45years. An annual income of less than 25 000 INR was significantly associated with HPV infection in all three districts (P<0.05). Regular intercourse was also associated with HPV in Erode and Salem (P<0.05). Screening and prophylactic vaccines containing HPV16 and HPV6 should be promoted in western Tamil Nadu. Copyright © 2014 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  10. The Cost of Surveillance After Urethroplasty

    PubMed Central

    Zaid, Uwais B.; Hawkins, Mitchel; Wilson, Leslie; Ting, Jie; Harris, Catherine; Alwaal, Amjad; Zhao, Lee C.; Morey, Allen F.; Breyer, Benjamin N.

    2015-01-01

    Objectives To determine variability in urethral stricture surveillance. Urethral strictures impact quality of life and exact a large economic burden. Although urethroplasty is the gold standard for durable treatment, strictures recur in 8–18%. There are no universally accepted guidelines for post-urethroplasty surveillance. We performed a literature search to evaluate variability in surveillance protocols, analyzed costs, and reviewed performance of each commonly employed modality. Methods Medline search was performed using the keywords: “urethroplasty,” “urethral stricture,” “stricture recurrence” to ascertain commonly used surveillance strategies for stricture recurrence. We included English language manuscripts from the past 10 years with at least 10 patients, and age greater than 18. Cost data was calculated based on standard 2013 Centers for Medicare and Medicaid Services physician’s fees. Results Surveillance methods included retrograde urethrogram/voiding cystourethrogram (RUG/VCUG), cystourethroscopy, urethral ultrasound, AUA-Symptom Score, and post void residual (PVR) and urine flowmetry (UF) measurement. Most protocols call for a RUG/VCUG at time of catheter removal. Following this, UF/PVR, cystoscopy, urine culture, or a combination of UF and AUA-SS were performed at variable intervals. The first year follow-up cost of anterior urethral surgery ranged from $205 to $1,784. For posterior urethral surgery, follow-up cost for the first year ranged from $404 to $961. Conclusions Practice variability for surveillance of urethral stricture recurrence after urethroplasty leads to significant differences in cost. PMID:25819624

  11. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF URINE SAMPLES (SOP-2.14)

    EPA Science Inventory

    This SOP describes the method for collecting urine samples from the study participants (children and their primary caregivers). Urine samples will be approximate 48-hr collections, collected as spot urine samples accumulated over the 48-hr sampling period. If the household or da...

  12. Porphyrins - urine test

    MedlinePlus

    Urine uroporphyrin; Urine coproporphyrin; Porphyria - uroporphyrin ... After you provide a urine sample, it is tested in the lab. This is called a random urine sample. If needed, your health care provider ...

  13. LOG-NORMAL DISTRIBUTION OF COSMIC VOIDS IN SIMULATIONS AND MOCKS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Russell, E.; Pycke, J.-R., E-mail: er111@nyu.edu, E-mail: jrp15@nyu.edu

    2017-01-20

    Following up on previous studies, we complete here a full analysis of the void size distributions of the Cosmic Void Catalog based on three different simulation and mock catalogs: dark matter (DM), haloes, and galaxies. Based on this analysis, we attempt to answer two questions: Is a three-parameter log-normal distribution a good candidate to satisfy the void size distributions obtained from different types of environments? Is there a direct relation between the shape parameters of the void size distribution and the environmental effects? In an attempt to answer these questions, we find here that all void size distributions of thesemore » data samples satisfy the three-parameter log-normal distribution whether the environment is dominated by DM, haloes, or galaxies. In addition, the shape parameters of the three-parameter log-normal void size distribution seem highly affected by environment, particularly existing substructures. Therefore, we show two quantitative relations given by linear equations between the skewness and the maximum tree depth, and between the variance of the void size distribution and the maximum tree depth, directly from the simulated data. In addition to this, we find that the percentage of voids with nonzero central density in the data sets has a critical importance. If the number of voids with nonzero central density reaches ≥3.84% in a simulation/mock sample, then a second population is observed in the void size distributions. This second population emerges as a second peak in the log-normal void size distribution at larger radius.« less

  14. The method of urine sampling is not a valid predictor for vesicoureteral reflux in children after febrile urinary tract infections.

    PubMed

    Haid, Bernhard; Roesch, Judith; Strasser, Christa; Oswald, Josef

    2017-10-01

    The likelihood of detecting vesicoureteral reflux (VUR) after febrile urinary tract infections (UTI) in children logically should correlate with the correct diagnosis of the UTI. Beneath the unspecific symptoms of fever urine analysis is the main diagnostic criterion for the exact diagnosis of febrile UTIs in children. Use of inadequate urine sampling techniques during diagnosis may lead to impaired accuracy in UTI diagnosis. This could lead to the assumption that children, having diagnosed their UTI by the use of possibly inadequate urine sampling techniques should not be evaluated as consequently compared to those, where the diagnosis relied on sterile urine sampling techniques. We hypothesized that children with possibly contaminated urine samples during the initial diagnosis may show a lower rate of VUR in subsequent VCUGs because of a wrong diagnosis initially compared to children, where accurate urine sampling techniques were used. Between 2009 and 2014, a total of 555 patients underwent a primary VCUG at our department indicated because of febrile UTIs. Patients with urine collection methods other than bag urine and catheter/suprapubic aspiration (SPA) were excluded from this study (mid-stream urine, potty urine, n = 149). We evaluated 402 patients (male/female 131/271, mean age 1.91 years), VUR rates and grades were compared between patients where urine was sampled by the use of a urine bag only at the time of diagnosis (n = 296, 73.6%) and those where sterile urine sampling (catheter, suprapubic puncture) was performed (n = 106, 26.3%). 4 patients were excluded due to equivocal data on urine sampling. VUR rate in children after sterile urine sampling using a catheter or SPA accounted to 31.1%. In those where urine samples acquired by the use of urine bags were used, 33.7% showed VUR on subsequent VCUG (p = 0.718). There were no significant differences as to VUR grades or gender, although VUR was much more commonly diagnosed in female patients (37.0% vs 28.2%, p = 0.227) (Figure). Children diagnosed with their UTI by use of bag urine in our experience carried the same risk of showing a VUR in a subsequent VCUG compared to those, where the initial diagnosis relied - beneath clinical criteria - on urine samples acquired by suprapubic puncture or catheterization. Consequently urine-sampling technique during initial UTI diagnosis alone should not be used as predictor for the reliability of UTI diagnosis and should not influence the further management after UTI. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  15. Hydration Status in US Military Officer Students.

    PubMed

    Rogers, Reva; Cole, Renee

    2016-01-01

    Relocation from a cool to a hot climate is a frequent occurrence in military service. Acclimatization requires time and exposure to heat. Nonacclimatized individuals frequently consume inadequate fluid leading to hypohydration, which can quickly result in dehydration with increased risk of heat illness/injury. This descriptive cross-sectional study assessed the hydration status of 196 officers attending the US Army Medical Department's Officer Basic Course (67%) or Captain's Career Course (33%) in San Antonio, Texas, prior to taking the Army Physical Fitness Test (APFT). Consenting Soldiers provided a first morning void urine sample and demographic survey (age, rank, sex, previous geographic location, etc) prior to the APFT. Height, weight, and APFT event scores were collected from a subject-coded, APFT scorecard without personal information data. Binary logistic regression was performed to identify variables that contribute to predicting hypohydration status. The sample population was 54% male, a mean age of 30 years, 5.2 years of military service, and a mean body mass index of 25 kg/m². Nearly one-third met the criteria for hypohydration (≥1.02 urine specific gravity). Soldiers who relocated from a cool environment within 9 days of taking the APFT had 2.1 higher odds of being hypohydrated compared with individuals who had resided in a hot environment for more than 9 days. Women had a 0.5 lower odds of being hypohydrated as compared to males. Significantly more Soldiers were hypohydrated on Monday compared to those tested on Tuesday (33% vs 16%, P=.004). Given these findings, the authors provided 5 recommendations to reduce the number of Soldiers exercising in a hypohydrated state.

  16. Oral fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure

    PubMed Central

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2018-01-01

    Background Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. Objective To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Methods Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multiplied-immunoassay-technique and in oral fluid by liquid chromatography tandem mass spectrometry (LC-MSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Results Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). Conclusion/Discussion These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. PMID:29173162

  17. Oral Fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure.

    PubMed

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2017-01-01

    Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multipliedimmunoassay- technique and in oral fluid by liquid chromatography tandem mass spectrometry (LCMSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  18. Urine sample (image)

    MedlinePlus

    A "clean-catch" urine sample is performed by collecting the sample of urine in midstream. Men or boys should wipe clean the head ... water and rinse well. A small amount of urine should initially fall into the toilet bowl before ...

  19. [Urinary tract infections--pediatric urologist point of view].

    PubMed

    Baka-Ostrowska, Małgorzata

    2008-01-01

    Urinary tract infections (UTI) could present with different clinical forms dependent on intensity and localization of infection and child's age. The symptoms could be non specific in children. Condition that provoke to urinary stasis, especially voiding dysfunction is the favourable factor for UTI appearance. Gram-negative enteric bacteria is the most common pathogen. Urine culture is the basic investigation that allow to identify pathogen and its drug sensitiveness but simultaneous urinalysis is necessary to recognize the inflammation of urinary organs. In addition, the number of leukocytes gives an idea about inflammation intensity. Ultrasonographic (USG) scan is necessary to examine urostasis. DMSA study performed during febrile UTI allow to identify children with acute pyelonephritis and when repeated 6 months later - those with renal scars. A normal USG and DMSA scan during infection makes voiding cystourethrography (VCU) unnecessary in the primary examination. The presence of vesicoureteric reflux (VUR) not always predispose children to renal lesions. Early and appropriate treatment of UTI, especially during the first 24 hours, diminishes the likelihood of renal involvement during the acute phase of infection but does not prevent scar formation. The proper hygiene of the urethral meatus, voiding and drinking habits and preventing of constipation are crucial in UTI prophylaxis.

  20. Comparison of routine urinalysis and urine Gram stain for detection of bacteriuria in dogs.

    PubMed

    Way, Leilani Ireland; Sullivan, Lauren A; Johnson, Valerie; Morley, Paul S

    2013-01-01

    To determine the utility of performing urine Gram stain for detection of bacteriuria compared to routine urine sediment examination and bacterial aerobic urine culture. Prospective, observational study. University teaching hospital. Urine samples acquired via cystocentesis through convenience sampling from 103 dogs presenting to a tertiary referral institution. All samples underwent routine urinalysis, including sediment examination, as well as urine Gram stain and quantitative bacterial aerobic urine culture. The urine Gram stain demonstrated improved sensitivity (96% versus 76%), specificity (100% versus 77%), positive predictive value (100% versus 83%), and negative predictive value (93% versus 69%) when identifying bacteriuria, compared to routine urine sediment examination. The urine Gram stain is highly sensitive and specific when detecting the presence of bacteria in canine urine samples. Gram staining should be considered when bacteriuria is highly suspected and requires rapid identification while bacterial culture is pending. © Veterinary Emergency and Critical Care Society 2013.

  1. Collapse of elongated voids in porous energetic materials: Effects of void orientation and aspect ratio on initiation

    NASA Astrophysics Data System (ADS)

    Rai, Nirmal Kumar; Schmidt, Martin J.; Udaykumar, H. S.

    2017-04-01

    The sensitivity of porous energetic materials depends on mesostructural heterogeneities such as voids, defects, cracks, and grain boundaries. The mesostructure of pressed explosives contains voids of arbitrary shapes including elongated voids of various orientations and aspect ratios. Mesoscale simulations to date have analyzed the effect of void morphology on the sensitivity of energetic materials for idealized shapes such as cylindrical, conical, and elliptical. This work analyzes the sensitivity behavior of elongated voids in an HMX matrix subject to shock loading. Simulations show that sensitivity of elongated voids depends strongly on orientation as well as aspect ratio. Ranges of orientations and aspects ratios are identified that enhance or inhibit initiation. Insights obtained from single elongated void analyses are used to identify sensitive locations in an imaged mesostructure of a pressed explosive sample.

  2. Advantage of multiple spot urine collections for estimating daily sodium excretion: comparison with two 24-h urine collections as reference.

    PubMed

    Uechi, Ken; Asakura, Keiko; Ri, Yui; Masayasu, Shizuko; Sasaki, Satoshi

    2016-02-01

    Several estimation methods for 24-h sodium excretion using spot urine sample have been reported, but accurate estimation at the individual level remains difficult. We aimed to clarify the most accurate method of estimating 24-h sodium excretion with different numbers of available spot urine samples. A total of 370 participants from throughout Japan collected multiple 24-h urine and spot urine samples independently. Participants were allocated randomly into a development and a validation dataset. Two estimation methods were established in the development dataset using the two 24-h sodium excretion samples as reference: the 'simple mean method' estimated by multiplying the sodium-creatinine ratio by predicted 24-h creatinine excretion, whereas the 'regression method' employed linear regression analysis. The accuracy of the two methods was examined by comparing the estimated means and concordance correlation coefficients (CCC) in the validation dataset. Mean sodium excretion by the simple mean method with three spot urine samples was closest to that by 24-h collection (difference: -1.62  mmol/day). CCC with the simple mean method increased with an increased number of spot urine samples at 0.20, 0.31, and 0.42 using one, two, and three samples, respectively. This method with three spot urine samples yielded higher CCC than the regression method (0.40). When only one spot urine sample was available for each study participant, CCC was higher with the regression method (0.36). The simple mean method with three spot urine samples yielded the most accurate estimates of sodium excretion. When only one spot urine sample was available, the regression method was preferable.

  3. Stability of cannabinoids in urine in three storage temperatures.

    PubMed

    Golding Fraga, S; Díaz-Flores Estévez, J; Díaz Romero, C

    1998-01-01

    Stability of cannabinoid compounds in urine samples were evaluated using several storage temperatures. Appreciable losses (> 22.4 percent) were observed in some urine samples, after being stored at room temperature for 10 days. Lower losses (8.1 percent) were observed when the urine samples were refrigerated for 4 weeks. The behavior of urine samples depended on the analyzed urine. This could be due to the different stability of the cannabinoids present in each urine sample. Important losses of 8.0 +/- 10.6, 15.8 +/- 4.2, and 19.6 +/- 6.7 percent were found when the urine samples were frozen during 40 days, 1 year, and 3 years, respectively. Average losses (> > 5 percent) can be observed after one day which could mainly be due to the decrease of the solubility of 11-nor-U9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) or adsorption process of cannabinoid molecules to the plastic storage containers.

  4. Substitution of human for horse urine disproves an accusation of doping*.

    PubMed

    Díaz, Silvina; Kienast, Mariana E; Villegas-Castagnasso, Egle E; Pena, Natalia L; Manganare, Marcos M; Posik, Diego; Peral-García, Pilar; Giovambattista, Guillermo

    2008-09-01

    In order to detect switching and/or manipulation of samples, the owner of a stallion asked our lab to perform a DNA test on a positive doping urine sample. The objective was to compare the urine DNA profile versus blood and hair DNA profiles from the same stallion. At first, 10 microsatellite markers were investigated to determine the horse identity. No results were obtained when horse specific markers were typed in the urine sample. In order to confirm the species origin of this sample we analyzed the mitochondrial cytochrome b gene. This analysis from blood and hair samples produced reproducible and clear PCR-RFLP patterns and DNA sequence match with those expected for horse, while the urine sample results were coincident with human. These results allowed us to exclude the urine sample from the questioned stallion and determine its human species origin, confirming the manipulation of urine sample.

  5. Gold nanoparticle incorporated inverse opal photonic crystal capillaries for optofluidic surface enhanced Raman spectroscopy.

    PubMed

    Zhao, Xiangwei; Xue, Jiangyang; Mu, Zhongde; Huang, Yin; Lu, Meng; Gu, Zhongze

    2015-10-15

    Novel transducers are needed for point of care testing (POCT) devices which aim at facile, sensitive and quick acquisition of health related information. Recent advances in optofluidics offer tremendous opportunities for biological/chemical analysis using extremely small sample volumes. This paper demonstrates nanostructured capillary tubes for surface enhanced Raman spectroscopy (SERS) analysis in a flow-through fashion. The capillary tube integrates the SERS sensor and the nanofluidic structure to synergistically offer sample delivery and analysis functions. Inside the capillary tube, inverse opal photonic crystal (IO PhC) was fabricated using the co-assembly approach to form nanoscale liquid pathways. In the nano-voids of the IO PhC, gold nanoparticles were in situ synthesized and functioned as the SERS hotspots. The advantages of the flow-through SERS sensor are multifold. The capillary effect facilities the sample delivery process, the nanofluidic channels boosts the interaction of analyte and gold nanoparticles, and the PhC structure strengthens the optical field near the SERS hotspots and results in enhanced SERS signals from analytes. As an exemplary demonstration, the sensor was used to measure creatinein spiked in artificial urine samples with detection limit of 0.9 mg/dL. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Urine melanin test

    MedlinePlus

    Thormahlen's test; Melanin - urine ... A clean-catch urine sample is needed. ... this substance that it shows up in the urine. ... Normally, melanin is not present in urine. Normal value ranges may ... measurements or test different samples. Talk to your health ...

  7. Is Childhood Abuse or Neglect Associated with Symptom Reports and Physiological Measures in Women with Irritable Bowel Syndrome?

    PubMed Central

    Heitkemper, Margaret M.; Cain, Kevin C.; Burr, Robert L.; Jun, Sang-Eun; Jarrett, Monica E.

    2013-01-01

    Purpose Early childhood traumatic experiences (e.g., abuse or neglect) may contribute to sleep disturbances as well as other indicators of arousal found in patients with irritable bowel syndrome (IBS). This study compared women with IBS positive for a history of childhood abuse and/or neglect to IBS women without this history, on daily gastrointestinal (GI), sleep, somatic, and psychological symptom distress, polysomnographic sleep, urine catecholamines and cortisol, and nocturnal heart rate variability (HRV). Methods Adult women with IBS recruited from the community were divided into 21 IBS with abuse/neglect and 19 IBS without abuse/neglect based on responses to the Childhood Trauma Questionnaire (physical, emotional, sexual abuse or neglect). Women were interviewed, maintained a 30-day symptom diary, and slept in a sleep laboratory. Polysomnographic and nocturnal heart rate variability data were obtained. First voided urine samples were assayed for cortisol and catecholamine levels. Results Women with IBS positive for abuse/neglect history were older than women without this history. Among GI symptoms, only heartburn and nausea were significantly higher in women with IBS with abuse/neglect. Sleep, somatic and psychological symptoms were significantly higher in women in the IBS with abuse/neglect group. With the exception of percent time in REM sleep, there were few differences in sleep stage variables and urine hormone levels. Mean heart rate interval and the Ln SDNN values were lower in those who experienced childhood abuse/neglect. Conclusion Women with IBS who self report childhood abuse/neglect are more likely to report disturbed sleep, somatic symptoms, and psychological distress. Women with IBS should be screened for adverse childhood events including abuse/neglect. PMID:21196423

  8. Urinary albumin and interleukin-8 levels are not good indicators of ongoing vesicoureteral reflux in children who have no active urinary tract infection.

    PubMed

    Badeli, Hamidreza; khoshnevis, Termeh; Hassanzadeh Rad, Afagh; Sadeghi, Mehrdad

    2013-01-01

    Vesicoureteral reflux (VUR) is a risk factor for kidney scarring, hypertension and declining renal function. Standard diagnostic methods are invasive and can cause exposure to radiation and urinary tract infections (UTIs). We aimed to investigate urine albumin and interleukin-8 levels as markers of ongoing VUR and renal damage in children without UTIs. Random urine samples were collected from 51 children, including 16 children with VUR (group A), 17 children with resolved VUR (group B) and 18 normal children (group C). The diagnosis of VUR or resolved VUR was confirmed by voiding cystourethrogram (VCUG) or direct radionuclide cystography (DRNC). All children had normal kidney function and had no evidence of UTI in the preceding three months. Random urine specimens were assayed for albumin (Alb), creatinine (Cr) and interleukin-8 (IL-8) and mean values were compared by one way ANOVA. In groups A and B, the mean age at first UTI was 31.7 ± 2.4 and 27 ± 2.0 months respectively. In group A, the mean duration between VUR diagnosis and study entrance was 30 ± 9.1 months. In group B, the mean duration between VUR diagnosis and recovery was 19.9 ± 1.3 months. Overall, 76.4% of affected children had bilateral VUR and 41.2% had severe VUR. There were no significant differences in urinary Alb, IL-8, Alb/Cr and IL-8/Cr between the three groups. The current study does not support the hypothesis that microalbuminuria or urinary IL-8 are good indicators of ongoing VUR and renal injury in children.

  9. Rapamycin attenuates bladder hypertrophy during long-term outlet obstruction in vivo: tissue, matrix and mechanistic insights.

    PubMed

    Schröder, Annette; Kirwan, Tyler P; Jiang, Jia-Xin; Aitken, Karen J; Bägli, Darius J

    2013-06-01

    Previous molecular studies showed that the mTOR inhibitor rapamycin prevents bladder smooth muscle hypertrophy in vitro. We investigated the effect of rapamycin treatment in vivo on bladder smooth muscle hypertrophy in a rat model of partial bladder outlet obstruction. A total of 48 female Sprague-Dawley® rats underwent partial bladder outlet obstruction and received daily subcutaneous injections of rapamycin (1 mg/kg) or vehicle commencing 2 weeks postoperatively. A total of 36 rats underwent sham surgery and received rapamycin or vehicle. Rats were sacrificed 3, 6 and 12 weeks after surgery. Before sacrifice, voiding was observed in a metabolic cage for 24 hours. Bladder-to-body weight in gm bladder weight per kg body weight and post-void residual urine were assessed. We evaluated Col1a1, Col3a1, Eln and Mmp7 mRNA expression and histology. Two-factor ANOVA and the post hoc t test were applied. Bladder outlet obstruction caused a significant increase in bladder weight in all obstructed groups. Three weeks postoperatively (1 week of treatment) there was no difference in the bladder-to-body weight ratio in the obstructed group. However, at 6 and 12 weeks (4 and 10 weeks of treatment, respectively) the bladder-to-body weight ratio of rats with obstruction plus rapamycin was significantly lower than that of rats with obstruction plus vehicle. Post-void residual urine volume after 6 and 12 weeks of obstruction was lower in obstructed rats with rapamycin compared to that in obstructed rats with vehicle. Rapamycin decreased the obstruction induced expression of Col1a1, Col3a1, Eln and Mmp7. Rapamycin prevents mechanically induced hypertrophy in cardiovascular smooth muscle. In vivo mTOR inhibition may attenuate obstruction induced detrusor hypertrophy and help preserve bladder function. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  10. Study of Psychological (and Associated Physiological) Effects on a Tank Crew Resulting from Being Buttoned Up

    DTIC Science & Technology

    1976-10-01

    should he made for either ixiternal storage or a means of voiding the urinal in a storage container in the compartment’. Development of-Adequate...upper temperature ranges fu- critical components of the M60 tank under desert storage and operational conditions. He found that the Wet Bulb Globe...five-gallon cans on the outside turret bustle racks. If buttoned-up operations for extended periods of time are envisioned, a built-in water storage

  11. Diagnostic value of JC/BK virus antibody immunohistochemistry staining in urine samples from posttransplant immunosuppressed patients in relation to polyomavirus reactivation.

    PubMed

    Yuste, Rosario Sanchez; Frías, Carolina; López, Ana; Vallejo, Carlos; Martín, Paloma; Bellas, Carmen

    2008-01-01

    To compare the diagnostic value of cytology and immunohistochemistry staining (IHS) of urine samples for polyomavirus reactivation diagnosis. Sixty-eight urine samples collected from 18 immunosuppressed patients were analyzed by Papanicolaou and IHS with a JC/BK virus-specific monoclonal antibody. Overall, polyomavirus BK (BKV) was positive in 11 of 18 patients (61.1%) (3 of whom developed hemorrhagic cystitis) and in 23 of 68 urine samples (28%). Of 23 samples, 4 (17%) were positive by 1 of the 2 techniques, only. Of 23 samples, 19 (83%) were positive by both methods. In matching urine samples from the same patient, the number of BKV-infected positive cells detected by IHS in urine slides was higher than those detected by Papanicolaou staining (71.3%). The main advantage of LHS is that it allowed confirmation of BKV infection diagnosis in urine samples. IHS detected more BKV-infected cells in samples with few positive urothelial cells, which would have gone undetected if only Papanicolaou staining had been used as the BKV screening method. Urine samples testing for BKV by both techniques will improve diagnosis in asymptomatic patients, allowing early therapeutic intervention and a better clinical outcome.

  12. Urinary retinoic acid receptor-β2 gene promoter methylation and hyaluronidase activity as noninvasive tests for diagnosis of bladder cancer.

    PubMed

    Eissa, Sanaa; Zohny, Samir F; Shehata, Hanan Hussien; Hegazy, Marwa G A; Salem, Ahmed M; Esmat, Mohamed

    2012-04-01

    We evaluated the significance of urinary retinoic acid receptor-β2 (RAR-β2) gene promoter methylation and hyaluronidase activity in comparison with voided urine cytology (VUC) in diagnosis of bladder cancer. This study included 100 patients diagnosed with bladder cancer, 65 patients with benign urological disorders and 51 healthy volunteers. Urine supernatant was used for determining hyaluronidase activity by zymography while urine sediment was used for cytology and detection of methylated RAR-β2 gene promoter by methylation specific nested PCR. The sensitivity and specificity were 53% and 90.5% for VUC, 65% and 89.7% for percent methylation fraction of RAR-β2 gene promoter, and 89% and 90.5% for hyaluronidase activity; combination of the three parameters increased sensitivity to 95%. A significant association was observed between investigated markers and advanced grade tumor. Combined use of RAR-β2 gene promoter methylation, hyaluronidase activity and VUC is promising non-invasive tool for bladder cancer detection. Copyright © 2012. Published by Elsevier Inc.

  13. Early effect of American Academy of Pediatrics Urinary Tract Infection Guidelines on radiographic imaging and diagnosis of vesicoureteral reflux in the emergency room setting.

    PubMed

    Arlen, Angela M; Merriman, Laura S; Kirsch, Jared M; Leong, Traci; Scherz, Hal C; Smith, Edwin A; Broecker, Bruce H; Kirsch, Andrew J

    2015-05-01

    In 2011 the AAP revised practice parameters on febrile urinary tract infection in infants and children 2 to 24 months old. New imaging recommendations invigorated the ongoing debate regarding the diagnosis and management of vesicoureteral reflux. We compared evaluations in these patients with febrile urinary tract infection before and after guideline publication. During 2 separate 6-month periods 350 patients 2 to 24 months old were evaluated in the emergency room setting. Demographics, urine culture, renal-bladder ultrasound, voiding cystourethrogram and admission status were assessed. A total of 172 patients presented with initial febrile urinary tract infection in 2011, of whom 47 (27.3%) required hospitalization, while 42 of 178 (23.6%) were admitted in 2012. Admission by year did not significantly differ (p = 0.423). After guideline revision 41.2% fewer voiding cystourethrograms were done (72.1% of cases in 2011 vs 30.9% in 2012, p <0.001). A 17.2% decrease in renal-bladder ultrasound was noted (75.6% in 2011 vs 58.4% in 2012, p <0.001). Of 55 voiding cystourethrograms 21 (38.2%) were positive in 2012 compared to 36.3% in 2011 (p = 0.809). Mean ± SD maximum vesicoureteral reflux grade was unchanged in 2011 and 2012 (2.9 ± 1.2 and 2.5 ± 0.93, respectively, p = 0.109). There was no association between abnormal renal-bladder ultrasound and voiding cystourethrogram positivity (p = 0.116). AAP guidelines impacted the treatment of infants and young children with febrile urinary tract infection. We found no relationship between renal-bladder ultrasound and abnormal voiding cystourethrogram, consistent with previous findings that call ultrasound into question as the determinant for additional imaging. Whether forgoing routine voiding cystourethrogram results in increased morbidity is the subject of ongoing study. Copyright © 2015. Published by Elsevier Inc.

  14. Basic or extended urine sampling to analyse urine production?

    PubMed

    Denys, Marie-Astrid; Kapila, Vansh; Weiss, Jeffrey; Goessaert, An-Sofie; Everaert, Karel

    2017-09-01

    Frequency volume charts are valuable tools to objectify urine production in patients with nocturia, enuresis or nocturnal incontinence. Analyses of daytime and nighttime urine (=basic collection) or analyses of urine samples collected every 3 h (=extended collection) extend this evaluation by describing circadian patterns of water and solute diuresis (=renal function profiles). To assess intra-individual correlation and agreement between renal function profiles provided using basic and extended urine collections, and using two extended urine collections. To create a short-form of the extended collection. This prospective observational study was executed at Ghent University Hospital, Belgium. Study participation was open for anyone visiting the hospital. Participants collected one basic and two extended 24-h urine collections. Urinary levels of osmolality, sodium and creatinine were determined. There was a moderate to strong correlation between results of basic and extended urinalyses. Comparing both extended urinalyses showed a moderate correlation between the eight individual samples and a weak to strong correlation between the mean daytime and nighttime values of renal functions. Different samples could be considered as most representative for mean daytime values, while all samples collected between 03 and 05am showed the highest agreement with mean nighttime values of renal function. Since there is a good correlation and agreement between basic and extended urine collections to study the mechanisms underlying urine production, the choice of urine sampling method to evaluate urine production depends on the purpose. A nighttime-only urine sample collected between 03 and 05am may be the most practical approach. © 2017 Wiley Periodicals, Inc.

  15. High performance liquid chromatographic method for the determination of cetirizine and ambroxol in human plasma and urine--a boxcar approach.

    PubMed

    Dharuman, J; Vasudhevan, M; Ajithlal, T

    2011-09-01

    A column switching high performance liquid chromatographic method with estimable sensitivity and accuracy was developed for the determination of cetirizine and ambroxol in human plasma using nebivolol as the internal standard. Plasma samples were prepared by liquid-liquid extraction in methylene chloride and a mixture of diethylether (80:20, v/v). The extracted samples were injected into a multifunctional clean-up column Supelcosil LCABZ (50 mm × 4.6 mm, 5 μm particle size) using mobile phase 1 comprising acetonitrile-phosphate buffer (pH 3.5; 20 mM) (20:80, v/v). The eluate of cetirizine and ambroxol were separated to an analytical Kromasil C(8) micro bore column (50 mm × 0.3 mm, 5 μm particle size) via a column switching device. A Kromasil C(18) analytical column (250 mm × 2.1 mm, 5 μm particle size) was used as a separation column. Mobile phase 2 consisting acetonitrile-triethylamine (0.5%) in phosphate buffer (pH 3.5; 20mM) (55:45, v/v) was used for the compound elution. The eluents were detected at 230 nm with photodiode array detector. An aliquot of 150 μl of plasma sample was introduced into the pretreatment column via the auto sampler using mobile phase 1 at a flow rate of 0.5 ml/min, column switching valve being positioned at A. The pretreatment column retained cetirizine, ambroxol and nebivolol (IS) in the column leaving the residual proteins of plasma eluted in void volume and drained out. The switching valve was shifted to position B at 7.5 min. Cetirizine, ambroxol and IS were eluted from the pretreatment column between 7. 5 and 11.5 min and introduced to the concentration column. Finally, cetirizine, ambroxol and IS were introduced to the separation column by switching valve using mobile phase 2 at a flow rate of 0.4 ml/min. During the analysis the pretreatment column was washed for the next analysis and resume to the position A. The total run time was 25 min for a sample. The procedure was repeated for urine analysis also. The method was linear from 2 to 450 ng/ml and 7-300 ng/ml for cetirizine and ambroxol respectively in plasma and 1-500 ng/ml and 5-400 ng/ml, respectively for cetirizine and ambroxol in urine. Intra-day and inter-day precision of cetirizine and ambroxol was below 15% in terms of coefficient of variation and accuracy of cetirizine and ambroxol was ranged from 94 to 101.6% and 91.1 to 100.2%, respectively. The method demonstrated high sensitivity and selectivity and therefore, applied to evaluate pharmacokinetics of cetirizine and ambroxol in healthy human volunteer after a single oral administration. Urine samples obtained from healthy human volunteers and clinical subjects with renal impairment have also been analyzed by the method to compare the elimination pattern. The method was precise and accurate for the estimation of cetirizine and ambroxol both in blood and in urine. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Role of pelvic floor in lower urinary tract function.

    PubMed

    Chermansky, Christopher J; Moalli, Pamela A

    2016-10-01

    The pelvic floor plays an integral part in lower urinary tract storage and evacuation. Normal urine storage necessitates that continence be maintained with normal urethral closure and urethral support. The endopelvic fascia of the anterior vaginal wall, its connections to the arcus tendineous fascia pelvis (ATFP), and the medial portion of the levator ani muscles must remain intact to provide normal urethral support. Thus, normal pelvic floor function is required for urine storage. Normal urine evacuation involves a series of coordinated events, the first of which involves complete relaxation of the external urethral sphincter and levator ani muscles. Acquired dysfunction of these muscles will initially result in sensory urgency and detrusor overactivity; however, with time the acquired voiding dysfunction can result in intermittent urine flow and incomplete bladder emptying, progressing to urinary retention in severe cases. This review will start with a discussion of normal pelvic floor anatomy and function. Next various injuries to the pelvic floor will be reviewed. The dysfunctional pelvic floor will be covered subsequently, with a focus on levator ani spasticity and stress urinary incontinence (SUI). Finally, future research directions of the interaction between the pelvic floor and lower urinary tract function will be discussed. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Scaling laws and deformation mechanisms of nanoporous copper under adiabatic uniaxial strain compression

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuan, Fuping, E-mail: fpyuan@lnm.imech.ac.cn; Wu, Xiaolei, E-mail: xlwu@imech.ac.cn

    2014-12-15

    A series of large-scale molecular dynamics simulations were conducted to investigate the scaling laws and the related atomistic deformation mechanisms of Cu monocrystal samples containing randomly placed nanovoids under adiabatic uniaxial strain compression. At onset of yielding, plastic deformation is accommodated by dislocations emitted from void surfaces as shear loops. The collapse of voids are observed by continuous emissions of dislocations from void surfaces and their interactions with further plastic deformation. The simulation results also suggest that the effect modulus, the yield stress and the energy aborption density of samples under uniaxial strain are linearly proportional to the relative densitymore » ρ. Moreover, the yield stress, the average flow stress and the energy aborption density of samples with the same relative density show a strong dependence on the void diameter d, expressed by exponential relations with decay coefficients much higher than -1/2. The corresponding atomistic mechanisms for scaling laws of the relative density and the void diameter were also presented. The present results should provide insights for understanding deformation mechanisms of nanoporous metals under extreme conditions.« less

  18. Neurotrophin/receptor expression in urinary bladder of mice with overexpression of NGF in urothelium.

    PubMed

    Girard, Beatrice M; Malley, Susan E; Vizzard, Margaret A

    2011-02-01

    Urothelium-specific overexpression of nerve growth factor (NGF) in the urinary bladder of transgenic mice stimulates neuronal sprouting in the urinary bladder, produces increased voiding frequency, and results in increased referred somatic hypersensitivity. Additional NGF-mediated pleiotropic changes might contribute to the increased voiding frequency and pelvic hypersensitivity observed in these transgenic mice, such as modulation of other growth factor/receptor systems. Chronic overexpression of NGF in the urothelium was achieved through the use of a highly urothelium-specific uroplakin II promoter. In the present study, we examined NGF, brain-derived neurotrophic factor (BDNF), and associated receptor [p75(NTR), tyrosine kinase (Trk)A, TrkB] transcript and protein expression in urothelium and detrusor smooth muscle of NGF-overexpressing (OE) and littermate wild-type mice, using real-time quantitative reverse transcription-polymerase chain reaction, ELISAs, and semiquantitation of immunohistochemistry. We focused on these growth factor/receptors given the established roles of NGF/TrkA, NGF/p75(NTR), and BDNF/TrkB systems in bladder function. Increased voiding frequency in NGF-OE mice was confirmed by examining urination patterns. BDNF, TrkA, and TrkB protein expression was significantly (P ≤ 0.01) reduced and p75(NTR) protein expression was significantly (P ≤ 0.01) increased in urinary bladder of NGF-OE mice. The NGF-OE-induced changes in neurotrophic factor/receptor expression in urinary bladder may represent compensatory changes to reduce voiding frequency in the NGF-OE mouse.

  19. Sacral root neuromodulation in idiopathic nonobstructive chronic urinary retention.

    PubMed

    Shaker, H S; Hassouna, M

    1998-05-01

    Sacral root neuromodulation is becoming a superior alternative to the standard treatment of idiopathic nonobstructive urinary retention. We report results in 20 successive patients who underwent sacral foramen implantation to restore bladder function. After an initial, thorough baseline assessment 20 patients 19.43 to 55.66 years old with idiopathic nonobstructive urinary retention underwent percutaneous nerve evaluation. Response was assessed by a detailed voiding diary. Responders underwent implantation with an S3 foramen implant, and were followed 1, 3 and 6 months postoperatively, and every 6 months thereafter. Sacral root neuromodulation restored voiding capability in these patients. Bladders were emptied with minimal post-void residual urine, which decreased from 78.3 to 5.5 to 10.2% of the total voided volume from baseline to postoperative followup. These results were reflected in uroflowmetry and pressure-flow studies, which were almost normal after implantation. Furthermore, the urinary tract infection rate decreased significantly and associated pelvic pain improved substantially. The Beck depression inventory and SF-36 quality of life questionnaire indicated some improvement but reached significance in only 1 item. In addition, cystometrography showed no significant difference after 6 months of implantation compared with baseline values. Complications were minimal and within expectations. Sacral root neuromodulation is an appealing, successful modality for nonobstructive urinary retention. Only patients who have a good response to percutaneous nerve evaluation are candidates for implantation. The high efficacy in patients who undergo implantation, relative simplicity of the procedure and low complication rate make this a treatment breakthrough in this difficult group.

  20. The effect of alpha blockers on uroflowmetric parameters in different voiding positions

    PubMed Central

    Koc, Gokhan; Yilmaz, Yuksel; Un, Sitki; Akbay, Kaan; Akdeniz, Firat

    2013-01-01

    Introduction: We assessed the effect of different voiding positions on uroflowmetric parameters and post-void residual (PVR) urine volume in symptomatic benign prostatic hyperplasia (BPH) patients. We also evaluated the effect of alpha blockers on PVR in different voiding positions. Methods: The study was performed with 110 BPH patients over 50 years old. In total, 4 uroflowmetries were performed in all patients: 2 patients in the sitting position and 2 in the standing position. PVR was measured with transabdominal ultrasonography. Also, patients were divided into two groups according to the alpha adrenergic blocker treatment; the effect of this treatment on their uroflowmetric parameters in different positions was evaluated. Results: Maximum flow rate (Qmax) and average flow rate (Qave) were significantly higher in patients in the sitting position, but there were no differences in other uroflowmetric parameters and PVR volume (Qmax: 15.5±5.9 mL/s vs. 13.7±5.2 mL/s, Qave: 11.4±4.6 mL/s vs. 10.7± 3.9 mL/s, respectively; p < 0.05). The Qmax and Qave were significantly higher in sitting position, compared to the standing position, in both alpha adrenergic treatment and non-treated groups; again, there were no differences in other uroflowmetric parameters and PVR volume. Conclusion: Qmax and Qave values were significantly higher in the sitting position. Alpha blockers did not affect any change. PMID:23766834

  1. Effects of diet composition on mutagenic activity in urine.

    PubMed

    Ohara, Akihiro; Matsuhisa, Tsugio

    2004-01-01

    The effects of dietary habits on mutagenic activity in urine were investigated using the umu test based on the use of the genetically engineered bacteria Salmonella typhimurium TA 1535 pSK1002. Genotoxic effects in sample urine were detected by measuring the activation of the SOS response in the bacteria and recording the beta- galactosidase activity. Human subjects consisted of smokers and non-smokers. Urine from subjects who consumed fish showed the highest mutagenic activity, followed by the urine samples from subjects who ate pork or beef. Chicken induced a low level of mutagenic activity. When the subjects ate fried or roasted animal foods, the urine samples gave higher mutagenicity than the urine samples from the subject who consumed non-fried or non-roasted animal foods. When the subject ate vegetables along with a diet rich in animal foods, the activity in urine decreased. Herbs and spices gave the same tendency toward decline as vegetables. Non-smoker urine shower mutagenic activity than samples from smokers.

  2. Comparison of initial stream urine samples and cervical samples for detection of human papillomavirus.

    PubMed

    Hagihara, Mao; Yamagishi, Yuka; Izumi, Koji; Miyazaki, Narimi; Suzuki, Takayoshi; Kato, Hideo; Nishiyama, Naoya; Koizumi, Yusuke; Suematsu, Hiroyuki; Mikamo, Hiroshige

    2016-08-01

    Uterine cervical cancer is a treatable and preventable cancer. Medical efforts to reduce rates of cervical cancer focus on the promotion of human papillomavirus (HPV) vaccination and the promotion of routine cervical cancer screening done by cervical cytology and cervical HPV testing. Urine-based HPV testing would be simple and noninvasive approach to screen for cervical cancer. Two biospecimens (clinician-taken sample from cervix and initial stream urine sample) were provided from a total of 240 healthy women attending for cancer screening provided for HPV testing. We have assessed the HPV detection rates among cervical samples and pellet fraction of urine samples using HPV test (Anyplex™ II HPV28 Detection kit, Seegene, Korea). Among 240 samples screened, HPV prevalence was 42.9% in pellet fractions of urine samples. The agreement between the two kinds of samples was 98.4%, k = 0.792. Discordant results were observed in 27 cases; 5 were positive only by urine samples and 22 were positive only by smear samples. Sensitivity and specificity for all HPV DNA in pellet fractions of urine using cervical samples as reference was 68.4% and 99.9%. Comparing methodologies of collection of samples for HPV detection, they showed the higher agreements for almost genotypes between cervical samples and pellet fractions of urine samples. These results suggest that urine could be a good noninvasive tool to monitor HPV infection in women. Additional research in a larger and general screening population would be needed. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  3. ONLY THE LONELY: H I IMAGING OF VOID GALAXIES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kreckel, K.; Van Gorkom, J. H.; Platen, E.

    2011-01-15

    Void galaxies, residing within the deepest underdensities of the Cosmic Web, present an ideal population for the study of galaxy formation and evolution in an environment undisturbed by the complex processes modifying galaxies in clusters and groups, as well as provide an observational test for theories of cosmological structure formation. We have completed a pilot survey for the H I imaging aspects of a new Void Galaxy Survey (VGS), imaging 15 void galaxies in H I in local (d < 100 Mpc) voids. H I masses range from 3.5 x 10{sup 8} to 3.8 x 10{sup 9} M{sub sun}, withmore » one nondetection with an upper limit of 2.1 x 10{sup 8} M{sub sun}. Our galaxies were selected using a structural and geometric technique to produce a sample that is purely environmentally selected and uniformly represents the void galaxy population. In addition, we use a powerful new backend of the Westerbork Synthesis Radio Telescope that allows us to probe a large volume around each targeted galaxy, simultaneously providing an environmentally constrained sample of fore- and background control samples of galaxies while still resolving individual galaxy kinematics and detecting faint companions in H I. This small sample makes up a surprisingly interesting collection of perturbed and interacting galaxies, all with small stellar disks. Four galaxies have significantly perturbed H I disks, five have previously unidentified companions at distances ranging from 50 to 200 kpc, two are in interacting systems, and one was found to have a polar H I disk. Our initial findings suggest void galaxies are a gas-rich, dynamic population which present evidence of ongoing gas accretion, major and minor interactions, and filamentary alignment despite the surrounding underdense environment.« less

  4. Antibiotic Screening of Urine Culture for Internal Quality Audit at Amrita Hospital, Kochi.

    PubMed

    Suresh, Aswathy; Gopinathan, Anusha; Dinesh, Kavitha R; Kumar, Anil

    2017-07-01

    Urine antimicrobial activity is a seldom analysed laboratory test which greatly impacts the quantification of urine specimens. Presence of antimicrobial activity in the urine reduces the bacterial load in these specimens. Hence, the chances of erroneously reporting insignificant bacteriuria can be reduced on analysis of the antimicrobial activity in urine. The aim of the study was to measure the antimicrobial activity of urine samples obtained from patients in a tertiary care hospital. A total of 100 urine specimens were collected from the study group. Tests like wet mount, Gram staining and culture were performed. Antimicrobial susceptibility testing was done on the bacteria isolated from each specimen. The urine specimens were reported as significant bacteriuria (>105 Colony Forming Unit (CFU)/ml) and insignificant bacteriuria (<105 CFU/ml - clean catch midstream urine; <102 CFU/ml - catheterized urine sample) according to the CFU/ml. Staphylococcus aureus ATCC ® 25923 ™ and Escherichia coli ATCC ® 25922 ™ were used to identify the presence of antimicrobial activity in the urine sample by Urine Anti-Bacterial substance Assay (UABA). McNemar test was used for statistical analysis using Statistical Package for the Social Sciences (SPSS) version 21.0. On analysis of the antimicrobial activity of urine sample with the prior antibiotic history of the patients, 17 were true positives and 43 were true negatives. Twenty six of samples with UABA positivity were culture negative and 28 samples with UABA positivity were culture positive. Sensitivity and specificity of the test was 85% and 53.8% respectively. Accuracy of the test was 60%. The p-value of UABA was <0.001. Enterobacteriaceae was the most common bacterial family isolated from the urine specimens. A total of 85% patients responded to treatment. Presence of antimicrobial activity in urine has a great impact on the interpretation of urine culture reports. Identification of urine antimicrobial activity helps in evaluating the quantification of bacterial growth reported in urine culture. It facilitates speedy recovery of patients by early administration of antibiotics.

  5. Mean population salt intake estimated from 24-h urine samples and spot urine samples: a systematic review and meta-analysis.

    PubMed

    Huang, Liping; Crino, Michelle; Wu, Jason H Y; Woodward, Mark; Barzi, Federica; Land, Mary-Anne; McLean, Rachael; Webster, Jacqui; Enkhtungalag, Batsaikhan; Neal, Bruce

    2016-02-01

    Estimating equations based on spot urine samples have been identified as a possible alternative approach to 24-h urine collections for determining mean population salt intake. This review compares estimates of mean population salt intake based upon spot and 24-h urine samples. We systematically searched for all studies that reported estimates of daily salt intake based upon both spot and 24-h urine samples for the same population. The associations between the two were quantified and compared overall and in subsets of studies. A total of 538 records were identified, 108 were assessed as full text and 29 were included. The included studies involved 10,414 participants from 34 countries and made 71 comparisons available for the primary analysis. Overall average population salt intake estimated from 24-h urine samples was 9.3 g/day compared with 9.0 g/day estimated from the spot urine samples. Estimates based upon spot urine samples had excellent sensitivity (97%) and specificity (100%) at classifying mean population salt intake as above or below the World Health Organization maximum target of 5 g/day. Compared with the 24-h samples, estimates based upon spot urine overestimated intake at lower levels of consumption and underestimated intake at higher levels of consumption. Estimates of mean population salt intake based upon spot urine samples can provide countries with a good indication of mean population salt intake and whether action on salt consumption is required. Published by Oxford University Press on behalf of the International Epidemiological Association 2015. This work is written by US Government employees and is in the public domain in the US.

  6. Estimating mean change in population salt intake using spot urine samples.

    PubMed

    Petersen, Kristina S; Wu, Jason H Y; Webster, Jacqui; Grimes, Carley; Woodward, Mark; Nowson, Caryl A; Neal, Bruce

    2017-10-01

    Spot urine samples are easier to collect than 24-h urine samples and have been used with estimating equations to derive the mean daily salt intake of a population. Whether equations using data from spot urine samples can also be used to estimate change in mean daily population salt intake over time is unknown. We compared estimates of change in mean daily population salt intake based upon 24-h urine collections with estimates derived using equations based on spot urine samples. Paired and unpaired 24-h urine samples and spot urine samples were collected from individuals in two Australian populations, in 2011 and 2014. Estimates of change in daily mean population salt intake between 2011 and 2014 were obtained directly from the 24-h urine samples and by applying established estimating equations (Kawasaki, Tanaka, Mage, Toft, INTERSALT) to the data from spot urine samples. Differences between 2011 and 2014 were calculated using mixed models. A total of 1000 participants provided a 24-h urine sample and a spot urine sample in 2011, and 1012 did so in 2014 (paired samples n = 870; unpaired samples n = 1142). The participants were community-dwelling individuals living in the State of Victoria or the town of Lithgow in the State of New South Wales, Australia, with a mean age of 55 years in 2011. The mean (95% confidence interval) difference in population salt intake between 2011 and 2014 determined from the 24-h urine samples was -0.48g/day (-0.74 to -0.21; P < 0.001). The corresponding result estimated from the spot urine samples was -0.24 g/day (-0.42 to -0.06; P = 0.01) using the Tanaka equation, -0.42 g/day (-0.70 to -0.13; p = 0.004) using the Kawasaki equation, -0.51 g/day (-1.00 to -0.01; P = 0.046) using the Mage equation, -0.26 g/day (-0.42 to -0.10; P = 0.001) using the Toft equation, -0.20 g/day (-0.32 to -0.09; P = 0.001) using the INTERSALT equation and -0.27 g/day (-0.39 to -0.15; P < 0.001) using the INTERSALT equation with potassium. There was no evidence that the changes detected by the 24-h collections and estimating equations were different (all P > 0.058). Separate analysis of the unpaired and paired data showed that detection of change by the estimating equations was observed only in the paired data. All the estimating equations based upon spot urine samples identified a similar change in daily salt intake to that detected by the 24-h urine samples. Methods based upon spot urine samples may provide an approach to measuring change in mean population salt intake, although further investigation in larger and more diverse population groups is required. © The Author 2016; all rights reserved. Published by Oxford University Press on behalf of the International Epidemiological Association

  7. Void Management in MEPHISTO and Other Space Experiments

    NASA Technical Reports Server (NTRS)

    deGroh, Henry C., III; Johnston, J. Christopher; Wei, Bingbo

    1998-01-01

    The second flight of NASA's Shuttle Flight experiment program known as MEPHISTO suffered from a void in the liquid portion of the sample, even though a piston arrangement was in place to keep the ampoule filled. In preparations for the next flight of the MEPHISTO furnace an animated computer program, called MEPHISTO Volume Visualizer (MVV), was written to help avoid the formation of unwanted voids. A piston system on MEPHISTO has the ability to move approximately 5 mm in compression, to accommodate expansion of the solid during heating; then from the completely compressed position, the piston can move up to 25 mm in towards the sample, effectively making the ampoule smaller and hopefully eliminating any voids. Due to the nature of the piston design and ampoule and sample arrangement, the piston has gotten stuck during normal directional solidification; this creates the risk of a void. To eliminate such a void, the liquid in the hot zones of the furnace can be heated, thereby expanding the liquid and consuming any void. The problem with this approach is that if the liquid is heated too much an overpressure could result, breaking the ampoule and ending the experiment catastrophically. The MVV has been found to be a useful tool in the assessment of the risks associated with the formation of a void and the additional heating of the liquid in the hot zone of this Bridgman type furnace. The MVV software will be discussed and copies available; it is written in the Delphi 2 programming language and runs under Windows 95 and NT. The strategies used in other flight experiments, such as the Isothermal Dendritic Growth Experiment, will also be presented.

  8. Monitoring of occupational exposure to methylene chloride: sampling protocol and stability of urine samples.

    PubMed

    Hoffer, Erica; Tabak, Arek; Shcherb, Inna; Wiener, Avi; Bentur, Yedidia

    2005-01-01

    A sampling protocol for biomonitoring of the volatile solvent methylene chloride (MeCl(2)) by analysis of urine from exposed workers was established. Storage temperature, sample volume in headspace vial (HSV), and time to sealing HSV on determination of MeCl(2) in urine were evaluated. MeCl(2) was analyzed by a solid-phase microextraction technique combined with gas chromatography. Volume of urine in HSV has no effect on MeCl(2) analysis. Delays of 30 and 60 min from collection of urine until sealing the HSV caused 14.47 +/- 6.98% and 26.17 +/- 9.57% decreases from baseline concentration, respectively. MeCl(2) concentration in spiked urine samples stored in sealed HSVs decreased on day 2 and then remained stable for 2 weeks. Refrigeration did not improve recovery although it seems to be associated with less variability. MeCl(2) in urine samples of seven exposed workers was in the range of 0.02-0.06 mg/L. Sampling of MeCl(2)-containing urine should include collection of urine in closed plastic bottles, transfer to HSV within 15 min, sealing and clamping of HSV within 15 s, and storage of HSV in refrigeration until analysis, but no longer than 2 weeks. Standard samples should be prepared on the day of test sample collection and handled under the same conditions.

  9. Gas-containing renal stones: findings from five consecutive patients.

    PubMed

    Manny, Ted B; Mufarrij, Patrick W; Lange, Jessica N; Mirzazadeh, Majid; Hemal, Ashok K; Assimos, Dean G

    2012-12-01

    To describe the clinical course, microbiology, and metabolic findings of 5 patients presenting to our institution with gas-containing renal stones. During a 20-month period beginning in 2009, 5 patients were identified by computed tomography scanning to harbor gas-containing renal calculi. Despite similar imaging and referral practice patterns, no such cases had been seen at our institution in the preceding 20 years. The records of these patients were reviewed to better characterize this unique condition. All 5 subjects were premenopausal women. One patient presented with urosepsis and 4 presented with flank pain. All had urinary tract infections, and Escherichia coli was isolated from a voided urine specimen in 3. Stone culture was positive in 2 and was concordant with the voided specimen in 1. The stones were solitary in 4 and multiple in 1 patient. All the stones were composed of calcium phosphate. Of the 5 patients, 3 had pure calcium phosphate stones and 2 had stones with calcium oxalate monohydrate components. Also, 3 subjects had diabetes mellitus, 3 had hypertension, and 1 had a history of gout. Two subjects underwent 24-hour urine metabolic testing, and abnormalities were identified in both. All patients were rendered stone free: 4 with percutaneous nephrostolithotomy and 1 using robotic pyelolithotomy. Gas-containing renal stones are rare but might be increasing in prevalence. The pathophysiology is unknown but is most likely influenced by a combination of metabolic and infectious factors. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. [Acute urinary retention secondary to giant prolapsed ureterocele in a young adult woman. Case report].

    PubMed

    Villagómez-Camargo, Roberto; Chopin-Gazga, Marco; Saucedo-Bravo, Jonathan; García-Cano, Eugenio; Montiel-Jarquín, Álvaro

    2016-01-01

    Ureterocele is a cystic dilation of the distal ureteral segment. The incidence in women ranges from 1/5,000 to 1/12,000. In adults, they are poorly diagnosed and are asymptomatic. Prolapse through the urethra is uncommon, and involves acute urine retention and a reducible vulvar tumour. Woman of 24 years old, two previous caesarean and two abortions. She had incomplete bladder emptying, intermittent voiding, bladder straining and tenesmus, three months before admission. After the voiding effort she presented with acute urine retention with sudden onset of tumour in the vulva. The tumour was manually reduced under regional anaesthesia. A cystoscopy was performed, finding an ischaemic de-roofing of the anterior wall of the ureterocele, causing vesicoureteral reflux grade IV. Surgical correction was performed with Cohen re-implantation and insertion of a double-J catheter. The catheter was removed 30 days later, with a successful post-operative course. Its aetiology is unclear, and most are diagnosed by ultrasound in the prenatal period. The clinical presentation is variable, from urinary tract infection to prolapse. Despite its size, it may cause complications such as ischaemic de-roofing, which if diagnosed soon may be resolved successfully, as with this patient. The results and treatment may be favourable when no renal impact or concomitant anatomical changes are present, as is the case of this patient. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  11. [First urinary tract infection in healthy infants: epidemiology, diagnosis and treatment].

    PubMed

    Capdevila Cogul, E; Martín Ibáñez, I; Mainou Cid, C; Toral Rodríguez, E; Cols Roig Mf; Agut Quijano, T; Caritg Bosch, J; Camarasa Piqué, F

    2001-10-01

    Urinary tract infection (UTI) is one of the most common infections in infants. It presents certain peculiarities compared with other pediatric age groups in terms of symptomatology, diagnosis and the therapeutic approach employed to prevent sequels. To analyze the epidemiology, clinical and laboratory findings, etiology, diagnosis and treatment of first-time UTI in healthy infants. Between January and December 1999, we performed a retrospective study of 131 previously healthy infants admitted to our hospital with a diagnosis of first-time UTI. Demographic data, clinical characteristics, urine dipstick, urinalysis and urine culture (vesical catheterization), blood cell count and PCR, kidney ultrasonography, voiding cystourethrogram and DMSA scintigraphy were reviewed. We studied 131 patients (median age: 90 days). In infants younger than 30 days, UTI was more prevalent in males. The most frequent symptom was fever (73.3 %). Seventy-one patients fulfilled the criteria for acute pyelonephritis. The presence of nitrituria was low. Escherichia coli was isolated in 90.1 % of the patients. Voiding cystourethrogram detected vesicoureteric reflux in 18.4 % of the patients. Scintigraphy revealed renal scarring in 15.1 %. No significant correlations were found between renal scarring in late scintigraphy and a diagnosis of acute pyelonephritis and/or alterations in the cystourethrogram. Fever was the main symptom. E. coli was the most commonly isolated microorganism. Nitrituria had low sensitivity in infants. Ultrasonography had low specificity. Scintigraphy showed the highest sensitivity and specificity in the detection of renal scarring. Predictability improved when scintigraphy was performed a few months after acute infection.

  12. Comparison of the Abbott RealTime High Risk HPV test and the Roche cobas 4800 HPV test using urine samples.

    PubMed

    Lim, Myong Cheol; Lee, Do-Hoon; Hwang, Sang-Hyun; Hwang, Na Rae; Lee, Bomyee; Shin, Hye Young; Jun, Jae Kwan; Yoo, Chong Woo; Lee, Dong Ock; Seo, Sang-Soo; Park, Sang-Yoon; Joo, Jungnam

    2017-05-01

    Human papillomavirus (HPV) testing based on cervical samples is important for use in cervical cancer screening. However, cervical sampling is invasive. Therefore, non-invasive methods for detecting HPV, such as urine samples, are needed. For HPV detection in urine samples, two real-time PCR (RQ-PCR) tests, Roche cobas 4800 test (Roche_HPV; Roche Molecular Diagnostics) and Abbott RealTime High Risk HPV test (Abbott_HPV; Abbott Laboratories) were compared to standard cervical samples. The performance of Roche_HPV and Abbott_HPV for HPV detection was evaluated at the National Cancer Center using 100 paired cervical and urine samples. The tests were also compared using urine samples stored at various temperatures and for a range of durations. The overall agreement between the Roche_HPV and Abbott_HPV tests using urine samples for any hrHPV type was substantial (86.0% with a kappa value of 0.7173), and that for HPV 16/18 was nearly perfect (99.0% with a kappa value of 0.9668). The relative sensitivities (based on cervical samples) for HPV 16/18 detection using Roche_HPV and Abbott_HPV with urine samples were 79.2% (95% CI; 57.9-92.9%) and 81.8% (95% CI; 59.7-94.8%), respectively. When the cut-off C T value for Abbott_HPV was extended to 40 for urine samples, the relative sensitivity of Abbott_HPV increased to 91.7% from 81.8% for HPV16/18 detection and to 87.0% from 68.5% for other hrHPV detection. The specificity was not affected by the change in the C T threshold. Roche_HPV and Abbott_HPV showed high concordance. However, HPV DNA detection using urine samples was inferior to HPV DNA detection using cervical samples. Interestingly, when the cut-off C T value was set to 40, Abbott_HPV using urine samples showed high sensitivity and specificity, comparable to those obtained using cervical samples. Fully automated DNA extraction and detection systems, such as Roche_HPV and Abbott_HPV, could reduce the variability in HPV detection and accelerate the standardization of HPV detection in urine. Thus, urine samples may be an effective alternative for HPV detection in women who hesitate to participate in cervical cancer screening programs. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Increased nocturnal blood pressure in enuretic children with polyuria.

    PubMed

    Kruse, Anne; Mahler, Birgitte; Rittig, Soren; Djurhuus, Jens Christian

    2009-10-01

    We investigated the association between nocturnal blood pressure and urine production in children with enuresis. A total of 39 consecutive children with a mean age of 9.8 years (range 6.2 to 14.9) with monosymptomatic nocturnal enuresis completed a bladder diary, including 2 weeks of basic documentation and 2 with desmopressin titration from 120 to 240 microg sublingually. Arterial blood pressure was measured every 30 minutes during 24 hours and during 4 additional nights using an ambulatory blood pressure monitor. Furthermore, 10 healthy children were recruited into the study who completed a bladder diary for 5 days while measuring arterial blood pressures with documentation of all intake and voided volumes. Patients with nocturnal polyuria had significantly higher nocturnal mean arterial pressure than patients without polyuria and controls (p <0.05). Furthermore, a positive correlation was seen between nocturnal urine output and nocturnal mean arterial pressure (r = 0.32, p <0.001). Nocturnal urine output was significantly higher during wet nights than dry nights (p <0.001). However, no significant difference was found in mean arterial pressure between wet and dry nights. Nocturnal mean arterial pressure was significantly higher in children with enuresis with polyuria than in children without polyuria. There was a significant positive correlation between average nocturnal mean arterial pressure and nocturnal urine volume in the whole study. The association between nocturnal blood pressure and urine volume, and the role of blood pressure should be investigated in a larger group of children with enuresis who have nocturnal polyuria.

  14. On the observability of coupled dark energy with cosmic voids

    NASA Astrophysics Data System (ADS)

    Sutter, P. M.; Carlesi, Edoardo; Wandelt, Benjamin D.; Knebe, Alexander

    2015-01-01

    Taking N-body simulations with volumes and particle densities tuned to match the sloan digital sky survey DR7 spectroscopic main sample, we assess the ability of current void catalogues to distinguish a model of coupled dark matter-dark energy from Λ cold dark matter cosmology using properties of cosmic voids. Identifying voids with the VIDE toolkit, we find no statistically significant differences in the ellipticities, but find that coupling produces a population of significantly larger voids, possibly explaining the recent result of Tavasoli et al. In addition, we use the universal density profile of Hamaus et al. to quantify the relationship between coupling and density profile shape, finding that the coupling produces broader, shallower, undercompensated profiles for large voids by thinning the walls between adjacent medium-scale voids. We find that these differences are potentially measurable with existing void catalogues once effects from survey geometries and peculiar velocities are taken into account.

  15. Design and use of mouse control DNA for DNA biomarker extraction and PCR detection from urine: application for transrenal Mycobacterium tuberculosis DNA detection

    PubMed Central

    Bordelon, Hali; Ricks, Keersten M.; Pask, Megan E.; Russ, Patricia K.; Solinas, Francesca; Baglia, Mark L.; Short, Philip A.; Nel, Andrew; Blackburn, Jonathan; Dheda, Keertan; Zamudio, Carlos; Cáceres, Tatiana; Wright, David W.; Haselton, Frederick R.; Pettit, April C.

    2017-01-01

    Urine samples are increasingly used for diagnosing infections including Escherichia coli, Ebola virus, and Zika virus. However, extraction and concentration of nucleic acid biomarkers from urine is necessary for many molecular detection strategies such as polymerase chain reaction (PCR). Since urine samples typically have large volumes with dilute biomarker concentrations making them prone to false negatives, another impediment for urine-based diagnostics is the establishment of appropriate controls particularly to rule out false negatives. In this study, a mouse glyceraldehyde 3-phosphate dehydrogenase (GAPDH) DNA target was added to retrospectively collected urine samples from tuberculosis (TB)-infected and TB-uninfected patients to indicate extraction of intact DNA and removal of PCR inhibitors from urine samples. We tested this design on surrogate urine samples, retrospective 1 milliliter (mL) urine samples from patients in Lima, Peru and retrospective 5 mL urine samples from patients in Cape Town, South Africa. Extraction/PCR control DNA was detectable in 97% of clinical samples with no statistically significant differences among groups. Despite the inclusion of this control, there was no difference in the amount of TB IS6110 Tr-DNA detected between TB-infected and TB-uninfected groups except for samples from known HIV-infected patients. We found a increase in TB IS6110 Tr-DNA between TB/HIV co-infected patients compared to TB-uninfected/HIV-infected patients (N=18, p=0.037). The inclusion of an extraction/PCR control DNA to indicate successful DNA extraction and removal of PCR inhibitors should be easily adaptable as a sample preparation control for other acellular sample types. PMID:28285168

  16. Design and use of mouse control DNA for DNA biomarker extraction and PCR detection from urine: Application for transrenal Mycobacterium tuberculosis DNA detection.

    PubMed

    Bordelon, Hali; Ricks, Keersten M; Pask, Megan E; Russ, Patricia K; Solinas, Francesca; Baglia, Mark L; Short, Philip A; Nel, Andrew; Blackburn, Jonathan; Dheda, Keertan; Zamudio, Carlos; Cáceres, Tatiana; Wright, David W; Haselton, Frederick R; Pettit, April C

    2017-05-01

    Urine samples are increasingly used for diagnosing infections including Escherichia coli, Ebola virus, and Zika virus. However, extraction and concentration of nucleic acid biomarkers from urine is necessary for many molecular detection strategies such as polymerase chain reaction (PCR). Since urine samples typically have large volumes with dilute biomarker concentrations making them prone to false negatives, another impediment for urine-based diagnostics is the establishment of appropriate controls particularly to rule out false negatives. In this study, a mouse glyceraldehyde 3-phosphate dehydrogenase (GAPDH) DNA target was added to retrospectively collected urine samples from tuberculosis (TB)-infected and TB-uninfected patients to indicate extraction of intact DNA and removal of PCR inhibitors from urine samples. We tested this design on surrogate urine samples, retrospective 1milliliter (mL) urine samples from patients in Lima, Peru and retrospective 5mL urine samples from patients in Cape Town, South Africa. Extraction/PCR control DNA was detectable in 97% of clinical samples with no statistically significant differences among groups. Despite the inclusion of this control, there was no difference in the amount of TB IS6110 Tr-DNA detected between TB-infected and TB-uninfected groups except for samples from known HIV-infected patients. We found an increase in TB IS6110 Tr-DNA between TB/HIV co-infected patients compared to TB-uninfected/HIV-infected patients (N=18, p=0.037). The inclusion of an extraction/PCR control DNA to indicate successful DNA extraction and removal of PCR inhibitors should be easily adaptable as a sample preparation control for other acellular sample types. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Role of positive urethrovesical feedback in vesical evacuation. The concept of a second micturition reflex: the urethrovesical reflex.

    PubMed

    Shafik, Ahmed; Shafik, Ali A; El-Sibai, Olfat; Ahmed, Ismail

    2003-08-01

    Upon feeling the urge to urinate, the urinary bladder contracts, the urethral sphincters relax and urine flows through the urethra. These actions are mediated by the micturition reflex. We investigated the hypothesis that vesical contraction is maintained by positive feedback through continuous flow of urine through the urethra, and that the cessation of urine flow aborts detrusor contraction. Normal saline was infused into the urinary bladders of 17 healthy volunteers (age 35.2 years+/-4.2(SD); ten women and seven men) at a rate of 100 ml/min. On urge, which occurred at a mean volume of 408.6 ml+/-28.7 of saline, the subject micturated while the vesical and urethral pressures during voiding were being recorded; residual urine was measured. The test was repeated after anesthetizing the urethra with xylocaine gel or, on another occasion, after applying a bland gel. On micturition, the urine was evacuated as a continuous stream without straining; no residual fluid was collected. After urethral anesthetization, the fluid came out of the urethra in multiple intermittent spurts and only with excessive straining. There was a large amount of residual fluid (184.6 ml+/-28.4). The results of bland gel application showed no significant difference ( P>0.05) from those without gel. Detrusor contraction during micturition is suggested to be maintained by positive urethrovesical feedback elicited by the continued passage of urine through the urethra. This feedback seems to be effected through the urethrovesical reflex, which produces vesical contraction on stimulation of the urethral stretch receptors. Abortion of this reflex by urethral anesthetization resulted in failure of detrusor contraction and excessive straining was needed to achieve bladder evacuation in multiple spurts. The urethrovesical reflex is thus assumed to constitute a second micturition reflex responsible for the continuation of detrusor contraction and urination. The role of this reflex in the pathogenesis of micturition disorders needs to be studied.

  18. Prevalence of Chlamydia trachomatis, Neisseria gonorrhoeae and Mycoplasma genitalium in asymptomatic patients under 30 years of age screened in a French sexually transmitted infections clinic.

    PubMed

    Clarivet, Béatrice; Picot, Eric; Marchandin, Hélène; Tribout, Vincent; Rachedi, Nadia; Schwartzentruber, Eric; Ledésert, Bernard; Dereure, Olivier; Guillot, Bernard; Picot, Marie-Christine

    2014-01-01

    An increasing prevalence of sexually transmitted infections (STI) has been noted in France over the past decade. Asymptomatic carriage may be high in patients infected with Chlamydia trachomatis attending free and anonymous screening centres (CDAG) and information, diagnosis and screening centres for STI (CIDDIST). In these centres, systematic C. trachomatis detection is recommended in women ≤25 years and in men ≤30 years. This study aimed at estimating the prevalence of C. trachomatis, Neisseria gonorrhoeae and Mycoplasma genitalium in asymptomatic patients younger than 30 years attending a CDAG-CIDDIST. A free systematic screening for C. trachomatis, N. gonorrhoeae and M. genitalium was offered to asymptomatic subjects under 30 years attending the Montpellier CDAG-CIDDIST from April to August 2009. Pathogens were identified by PCR in first void urine samples. Of the 1381 subjects included (53.8% women and 46.2% men), 105 (42.9% men and 57.1% women) tested positive for C. trachomatis (7.6%, 95% CI [6.3;9.13]); eight (seven men and one woman) tested positive for M. genitalium (0.58% [0.2;1]) of whom two were infected with C. trachomatis ; five (two men and three women) tested positive for N. gonorrhoeae (0.36% [0.1;0.8]) of whom three were infected with C. trachomatis. This study confirmed the need for C. trachomatis screening in all patients under 30 years. Our results did not support a systematic screening for N. gonorrhoeae and M. genitalium in urine samples in this kind of facility.

  19. Void growth and coalescence in irradiated copper under deformation

    NASA Astrophysics Data System (ADS)

    Barrioz, P. O.; Hure, J.; Tanguy, B.

    2018-04-01

    A decrease of fracture toughness of irradiated materials is usually observed, as reported for austenitic stainless steels in Light Water Reactors (LWRs) or copper alloys for fusion applications. For a wide range of applications (e.g. structural steels irradiated at low homologous temperature), void growth and coalescence fracture mechanism has been shown to be still predominant. As a consequence, a comprehensive study of the effects of irradiation-induced hardening mechanisms on void growth and coalescence in irradiated materials is required. The effects of irradiation on ductile fracture mechanisms - void growth to coalescence - are assessed in this study based on model experiments. Pure copper thin tensile samples have been irradiated with protons up to 0.01 dpa. Micron-scale holes drilled through the thickness of these samples subjected to uniaxial loading conditions allow a detailed description of void growth and coalescence. In this study, experimental data show that physical mechanisms of micron-scale void growth and coalescence are similar between the unirradiated and irradiated copper. However, an acceleration of void growth is observed in the later case, resulting in earlier coalescence, which is consistent with the decrease of fracture toughness reported in irradiated materials. These results are qualitatively reproduced with numerical simulations accounting for irradiation macroscopic hardening and decrease of strain-hardening capability.

  20. Gravitational Effects on Closed-Cellular-Foam Microstructure

    NASA Technical Reports Server (NTRS)

    Noever, David A.; Cronise, Raymond J.; Wessling, Francis C.; McMannus, Samuel P.; Mathews, John; Patel, Darayas

    1996-01-01

    Polyurethane foam has been produced in low gravity for the first time. The cause and distribution of different void or pore sizes are elucidated from direct comparison of unit-gravity and low-gravity samples. Low gravity is found to increase the pore roundness by 17% and reduce the void size by 50%. The standard deviation for pores becomes narrower (a more homogeneous foam is produced) in low gravity. Both a Gaussian and a Weibull model fail to describe the statistical distribution of void areas, and hence the governing dynamics do not combine small voids in either a uniform or a dependent fashion to make larger voids. Instead, the void areas follow an exponential law, which effectively randomizes the production of void sizes in a nondependent fashion consistent more with single nucleation than with multiple or combining events.

  1. Should acidification of urine be performed before the analysis of calcium, phosphate and magnesium in the presence of crystals?

    PubMed

    Pratumvinit, Busadee; Reesukumal, Kanit; Wongkrajang, Preechaya; Khejonnit, Varanya; Klinbua, Cherdsak; Dangneawnoi, Weerapol

    2013-11-15

    Acidification of urine has been recommended before testing for calcium, phosphate, and magnesium. We investigated the necessity of pre-analytical acidification in both crystallized and non-crystallized urine samples. From 130 urine samples obtained via routine urine analysis, 65 (50%) samples were classified as non-crystallized. All samples were divided into three groups: untreated samples, acidified samples with HCl, and acidified samples after 1h room-temperature incubation. Urine samples were measured for calcium, phosphate, magnesium, and creatinine using Modular P800 and were examined for crystals using light microscopy. In crystallized samples, acidified samples with 1h incubation had significantly higher Ca/Cr, P/Cr, and Mg/Cr than did untreated samples with mean differences of 0.04, 0.03, and 0.01 mg/mg, respectively (P<0.001). In acidified samples that were analyzed immediately, crystallized samples had lower calcium concentrations than those of acidified samples with 1h incubation and a mean difference of 0.21 mg/dl (P = 0.025). None of the sample differences which exceeded the critical difference of urinary Ca, P and Mg was observed. Acidification of urine should be performed before the measurement of Ca, P, and Mg in the presence of urinary crystals. However, the lack of an acidification process does not result in a clinically significant change. © 2013.

  2. Urine osmolality in the US population: Implications for environmental biomonitoring

    PubMed Central

    Yeh, Hung-Chieh; Lin, Yu-Sheng; Kuo, Chin-Chi; Weidemann, Darcy; Weaver, Virginia; Fadrowski, Jeffrey; Neu, Alicia; Navas-Acien, Ana

    2018-01-01

    Background For many environmental chemicals, concentrations in spot urine samples are considered valid surrogates of exposure and internal dose. To correct for urine dilution, spot urine concentrations are commonly adjusted for urinary creatinine. There are, however, several concerns about the use of urine creatinine. While urine osmolality is an attractive alternative; its characteristics and determinants in the general population remain unknown. Our objective was to describe the determinants of urine osmolality and to contrast the difference between osmolality and creatinine in urine. Methods From the National Health and Nutrition Examination Survey (NHANES) 2009–2012, 10,769 participants aged 16 years or older with measured urine osmolality and creatinine were used in the analysis. Very dilute and very concentrated urine was defined as urine creatinine lower than 0.3 g/l and higher than 3 g/l, respectively. Linear and logistic regression analyses were performed to investigate the associations of interest. Results Urine osmolality and creatinine were highly correlated (Pearson correlation coefficient = 0.75) and their respective median values were 648 mOsm/kg and 1.07 g/l. The prevalence of very dilute and very concentrated urine samples was 8.1% and 3.1%, respectively. Factors associated in the same direction with both urine osmolality and urine creatinine included age, sex, race, body mass index (BMI), hypertension, water intake, and blood osmolality. The magnitude of associations expressed as percent change was significantly stronger with creatinine than osmolality. Compared to urine creatinine, urine osmolality did not vary by diabetes status but was affected by daily total protein intake. Participants with chronic kidney disease (CKD) had significantly higher urine creatinine concentrations but lower urine osmolality. Both very dilute and concentrated urine were associated with a diverse array of sociodemographic, medical conditions, and dietary factors. For instance, females were approximately 3.3 times more likely to have urine over-dilution than male [the adjusted odds ratios (95% CI) = 3.27 (2.10–5.10)]. Conclusion Although the determinants of urine osmolality were generally similar to those of urine creatinine, the relative influence of socio-demographic and medical conditions was less on urine osmolality than on urine creatinine. Protocols for spot urine sample collection could recommend avoiding excessive and insufficient water intake before urine sampling to improve urine adequacy. The feasibility of adopting urine osmolality adjustment and water intake recommendations before providing spot urine samples for environmental biomonitoring merits further investigation. PMID:25460670

  3. Reliable Quantification of the Potential for Equations Based on Spot Urine Samples to Estimate Population Salt Intake: Protocol for a Systematic Review and Meta-Analysis.

    PubMed

    Huang, Liping; Crino, Michelle; Wu, Jason Hy; Woodward, Mark; Land, Mary-Anne; McLean, Rachael; Webster, Jacqui; Enkhtungalag, Batsaikhan; Nowson, Caryl A; Elliott, Paul; Cogswell, Mary; Toft, Ulla; Mill, Jose G; Furlanetto, Tania W; Ilich, Jasminka Z; Hong, Yet Hoi; Cohall, Damian; Luzardo, Leonella; Noboa, Oscar; Holm, Ellen; Gerbes, Alexander L; Senousy, Bahaa; Pinar Kara, Sonat; Brewster, Lizzy M; Ueshima, Hirotsugu; Subramanian, Srinivas; Teo, Boon Wee; Allen, Norrina; Choudhury, Sohel Reza; Polonia, Jorge; Yasuda, Yoshinari; Campbell, Norm Rc; Neal, Bruce; Petersen, Kristina S

    2016-09-21

    Methods based on spot urine samples (a single sample at one time-point) have been identified as a possible alternative approach to 24-hour urine samples for determining mean population salt intake. The aim of this study is to identify a reliable method for estimating mean population salt intake from spot urine samples. This will be done by comparing the performance of existing equations against one other and against estimates derived from 24-hour urine samples. The effects of factors such as ethnicity, sex, age, body mass index, antihypertensive drug use, health status, and timing of spot urine collection will be explored. The capacity of spot urine samples to measure change in salt intake over time will also be determined. Finally, we aim to develop a novel equation (or equations) that performs better than existing equations to estimate mean population salt intake. A systematic review and meta-analysis of individual participant data will be conducted. A search has been conducted to identify human studies that report salt (or sodium) excretion based upon 24-hour urine samples and spot urine samples. There were no restrictions on language, study sample size, or characteristics of the study population. MEDLINE via OvidSP (1946-present), Premedline via OvidSP, EMBASE, Global Health via OvidSP (1910-present), and the Cochrane Library were searched, and two reviewers identified eligible studies. The authors of these studies will be invited to contribute data according to a standard format. Individual participant records will be compiled and a series of analyses will be completed to: (1) compare existing equations for estimating 24-hour salt intake from spot urine samples with 24-hour urine samples, and assess the degree of bias according to key demographic and clinical characteristics; (2) assess the reliability of using spot urine samples to measure population changes in salt intake overtime; and (3) develop a novel equation that performs better than existing equations to estimate mean population salt intake. The search strategy identified 538 records; 100 records were obtained for review in full text and 73 have been confirmed as eligible. In addition, 68 abstracts were identified, some of which may contain data eligible for inclusion. Individual participant data will be requested from the authors of eligible studies. Many equations for estimating salt intake from spot urine samples have been developed and validated, although most have been studied in very specific settings. This meta-analysis of individual participant data will enable a much broader understanding of the capacity for spot urine samples to estimate population salt intake.

  4. Pathogens and pharmaceuticals in source-separated urine in eThekwini, South Africa.

    PubMed

    Bischel, Heather N; Özel Duygan, Birge D; Strande, Linda; McArdell, Christa S; Udert, Kai M; Kohn, Tamar

    2015-11-15

    In eThekwini, South Africa, the production of agricultural fertilizers from human urine collected from urine-diverting dry toilets is being evaluated at a municipality scale as a way to help finance a decentralized, dry sanitation system. The present study aimed to assess a range of human and environmental health hazards in source-separated urine, which was presumed to be contaminated with feces, by evaluating the presence of human pathogens, pharmaceuticals, and an antibiotic resistance gene. Composite urine samples from households enrolled in a urine collection trial were obtained from urine storage tanks installed in three regions of eThekwini. Polymerase chain reaction (PCR) assays targeted 9 viral and 10 bacterial human pathogens transmitted by the fecal-oral route. The most frequently detected viral pathogens were JC polyomavirus, rotavirus, and human adenovirus in 100%, 34% and 31% of samples, respectively. Aeromonas spp. and Shigella spp. were frequently detected gram negative bacteria, in 94% and 61% of samples, respectively. The gram positive bacterium, Clostridium perfringens, which is known to survive for extended times in urine, was found in 72% of samples. A screening of 41 trace organic compounds in the urine facilitated selection of 12 priority pharmaceuticals for further evaluation. The antibiotics sulfamethoxazole and trimethoprim, which are frequently prescribed as prophylaxis for HIV-positive patients, were detected in 95% and 85% of samples, reaching maximum concentrations of 6800 μg/L and 1280 μg/L, respectively. The antiretroviral drug emtricitabine was also detected in 40% of urine samples. A sulfonamide antibiotic resistance gene (sul1) was detected in 100% of urine samples. By coupling analysis of pathogens and pharmaceuticals in geographically dispersed samples in eThekwini, this study reveals a range of human and environmental health hazards in urine intended for fertilizer production. Collection of urine offers the benefit of sequestering contaminants from environmental release and allows for targeted treatment of potential health hazards prior to agricultural application. The efficacy of pathogen and pharmaceutical inactivation, transformation or removal during urine nutrient recovery processes is thus briefly reviewed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Comparison between Indirect Immunofluorescence Assay and Shell Vial Culture for Detection of Mumps Virus from Clinical Samples

    PubMed Central

    Reina, Jordi; Ballesteros, Francisca; Ruiz de Gopegui, Enrique; Munar, Maria; Mari, Margarita

    2003-01-01

    We report a prospective comparison of the efficacies of an indirect immunofluorescence assay (IFA) and shell vial culture (SVC) of throat swab and urine samples from patients with mumps. Throat swab samples were used for the IFA; the urine samples and throat swabs were inoculated into vials of Vero cells. We studied 62 patients by using 62 throat swabs and 50 urine samples (50 patients with both samples). Sixty (96.7%) throat samples were positive in the SVC, and 61 (98.3%) were positive in the IFA. For the 50 patients from whom both samples were available, the IFA was positive in 50 (100%) cases, the urine sample was positive in 49 (98%) cases, and the throat swab was positive in 48 (96%) cases (P > 0.05). This comparison of throat swabs and urine samples has shown that the two clinical samples are similar in efficacy. PMID:14605158

  6. A method for estimating radioactive cesium concentrations in cattle blood using urine samples.

    PubMed

    Sato, Itaru; Yamagishi, Ryoma; Sasaki, Jun; Satoh, Hiroshi; Miura, Kiyoshi; Kikuchi, Kaoru; Otani, Kumiko; Okada, Keiji

    2017-12-01

    In the region contaminated by the Fukushima nuclear accident, radioactive contamination of live cattle should be checked before slaughter. In this study, we establish a precise method for estimating radioactive cesium concentrations in cattle blood using urine samples. Blood and urine samples were collected from a total of 71 cattle on two farms in the 'difficult-to-return zone'. Urine 137 Cs, specific gravity, electrical conductivity, pH, sodium, potassium, calcium, and creatinine were measured and various estimation methods for blood 137 Cs were tested. The average error rate of the estimation was 54.2% without correction. Correcting for urine creatinine, specific gravity, electrical conductivity, or potassium improved the precision of the estimation. Correcting for specific gravity using the following formula gave the most precise estimate (average error rate = 16.9%): [blood 137 Cs] = [urinary 137 Cs]/([specific gravity] - 1)/329. Urine samples are faster to measure than blood samples because urine can be obtained in larger quantities and has a higher 137 Cs concentration than blood. These advantages of urine and the estimation precision demonstrated in our study, indicate that estimation of blood 137 Cs using urine samples is a practical means of monitoring radioactive contamination in live cattle. © 2017 Japanese Society of Animal Science.

  7. Long-term frozen storage of urine samples: a trouble to get PCR results in Schistosoma spp. DNA detection?

    PubMed

    Fernández-Soto, Pedro; Velasco Tirado, Virginia; Carranza Rodríguez, Cristina; Pérez-Arellano, José Luis; Muro, Antonio

    2013-01-01

    Human schistosomiasis remains a serious worldwide public health problem. At present, a sensitive and specific assay for routine diagnosis of schistosome infection is not yet available. The potential for detecting schistosome-derived DNA by PCR-based methods in human clinical samples is currently being investigated as a diagnostic tool with potential application in routine schistosomiasis diagnosis. Collection of diagnostic samples such as stool or blood is usually difficult in some populations. However, urine is a biological sample that can be collected in a non-invasive method, easy to get from people of all ages and easy in management, but as a sample for PCR diagnosis is still not widely used. This could be due to the high variability in the reported efficiency of detection as a result of the high variation in urine samples' storage or conditions for handling and DNA preservation and extraction methods. We evaluate different commercial DNA extraction methods from a series of long-term frozen storage human urine samples from patients with parasitological confirmed schistosomiasis in order to assess the PCR effectiveness for Schistosoma spp. detection. Patients urine samples were frozen for 18 months up to 7 years until use. Results were compared with those obtained in PCR assays using fresh healthy human urine artificially contaminated with Schistosoma mansoni DNA and urine samples from mice experimentally infected with S. mansoni cercariae stored frozen for at least 12 months before use. PCR results in fresh human artificial urine samples using different DNA based extraction methods were much more effective than those obtained when long-term frozen human urine samples were used as the source of DNA template. Long-term frozen human urine samples are probably not a good source for DNA extraction for use as a template in PCR detection of Schistosoma spp., regardless of the DNA method of extraction used.

  8. Assessment of lower urinary tract function in children with Down syndrome.

    PubMed

    Kitamura, Atsuko; Kondoh, Tatsuro; Noguchi, Mitsuru; Hatada, Teppei; Tohbu, Shohei; Mori, Ken-Ichi; Matsuo, Manabu; Kunitsugu, Ichiro; Kanetake, Hiroshi; Moriuchi, Hiroyuki

    2014-12-01

    Despite the fact that functional lower urinary tract symptoms are common among people with Down syndrome (DS), their voiding function has not been studied precisely. Our goal was to assess the lower urinary tract functions in DS. Fifty-five DS children aged 5-15 years old and 35 age-matched control children were evaluated by ultrasonography and uroflowmetry. Eleven (20%) DS children had no uresiesthesia, 21 (38%) were urinated under guidance, nine (16%) urinated fewer than three times a day, two (4%) urinated more than 10 times a day, three (5%) used diapers, and 26 (47%) had urinary incontinence. Seven (13%), 15 (27%), and 10 (18%) DS children had weak, prolonged and intermittent urination, respectively, and seven (13%) had urination with straining. In contrast, none of the control subjects had urinary problems. In the uroflowmetrical analysis, 10 (18%), 20 (37%), 11 (20%) and five (9%) DS children showed "bell-shaped," "plateau," "staccato" and "interrupted" patterns, respectively; the remaining nine (16%) could not be analyzed. In contrast, 21 (60%), one (3%), four (11%), three (9%) and two (6%) control subjects showed bell-shaped, tower-shaped, plateau, staccato and interrupted patterns, respectively; the remaining four (11%) could not be analyzed. Residual urine was demonstrated in four (7%) DS children and one (3%) control child. Lower urinary tract symptoms and abnormal uroflowmetry findings, which can lead to further progressive renal and urinary disorders, are common in DS children. Therefore, lower urinary tract functions should be assessed at the life-long regular medical check-ups for subjects with DS. © 2014 The Authors. Pediatrics International published by Wiley Publishing Asia Pty Ltd on behalf of Japan Pediatric Society.

  9. Arsenic drinking water exposure and urinary excretion among adults in the Yaqui Valley, Sonora, Mexico.

    PubMed

    Meza, Maria Mercedes; Kopplin, Michael J; Burgess, Jefferey L; Gandolfi, A Jay

    2004-10-01

    The objective of this study was to determine arsenic exposure via drinking water and to characterize urinary arsenic excretion among adults in the Yaqui Valley, Sonora, Mexico. A cross-sectional study was conducted from July 2001 to May 2002. Study subjects were from the Yaqui Valley, Sonora, Mexico, residents of four towns with different arsenic concentrations in their drinking water. Arsenic exposure was estimated through water intake over 24 h. Arsenic excretion was assessed in the first morning void urine. Total arsenic concentrations and their species arsenate (As V), arsenite (As III), monomethyl arsenic (MMA), and dimethyl arsenic (DMA) were determined by HPLC/ICP-MS. The town of Esperanza with the highest arsenic concentration in water had the highest daily mean intake of arsenic through drinking water, the mean value was 65.5 microg/day. Positive correlation between total arsenic intake by drinking water/day and the total arsenic concentration in urine (r = 0.50, P < 0.001) was found. Arsenic excreted in urine ranged from 18.9 to 93.8 microg/L. The people from Esperanza had the highest geometric mean value of arsenic in urine, 65.1 microg/L, and it was statistically significantly different from those of the other towns (P < 0.005). DMA was the major arsenic species in urine (47.7-67.1%), followed by inorganic arsenic (16.4-25.4%), and MMA (7.5-15%). In comparison with other reports the DMA and MMA distribution was low, 47.7-55.6% and 7.5-9.7%, respectively, in the urine from the Yaqui Valley population (except the town of Cocorit). The difference in the proportion of urinary arsenic metabolites in those towns may be due to genetic polymorphisms in the As methylating enzymes of these populations.

  10. Urinary Sodium-to-Potassium Ratio Tracks the Changes in Salt Intake during an Experimental Feeding Study Using Standardized Low-Salt and High-Salt Meals among Healthy Japanese Volunteers

    PubMed Central

    Yatabe, Midori Sasaki; Watanabe, Ami; Takano, Kozue; Sanada, Hironobu; Ichihara, Atsuhiro; Felder, Robin A.; Miura, Katsuyuki; Ueshima, Hirotsugu; Kimura, Junko; Yatabe, Junichi

    2017-01-01

    The Na/K ratio is considered to be a useful index, the monitoring of which allows an effective Na reduction and K increase, because practical methods (self-monitoring devices and reliable individual estimates from spot urine) are available for assessing these levels in individuals. An intervention trial for lowering the Na/K ratio has demonstrated that a reduction of the Na/K ratio mainly involved Na reduction, with only a small change in K. The present study aimed to clarify the relationship between dietary Na intake and the urinary Na/K molar ratio, using standardized low- and high-salt diets, with an equal dietary K intake, to determine the corresponding Na/K ratio. Fourteen healthy young adult volunteers ingested low-salt (3 g salt per day) and high-salt (20 g salt per day) meals for seven days each. Using a portable urinary Na/K meter, participants measured their spot urine at each voiding, and 24-h urine was collected on the last day of each diet period. On the last day of the unrestricted, low-salt, and high-salt diet periods, the group averages of the 24-h urine Na/K ratio were 4.2, 1.0, and 6.9, while the group averages of the daily mean spot urine Na/K ratio were 4.2, 1.1, and 6.6, respectively. The urinary Na/K ratio tracked changes in dietary salt intake, and reached a plateau approximately three days after each change in diet. Frequent monitoring of the spot urine Na/K ratio may help individuals adhere to an appropriate dietary Na intake. PMID:28850062

  11. Urinary Sodium-to-Potassium Ratio Tracks the Changes in Salt Intake during an Experimental Feeding Study Using Standardized Low-Salt and High-Salt Meals among Healthy Japanese Volunteers.

    PubMed

    Yatabe, Midori Sasaki; Iwahori, Toshiyuki; Watanabe, Ami; Takano, Kozue; Sanada, Hironobu; Watanabe, Tsuyoshi; Ichihara, Atsuhiro; Felder, Robin A; Miura, Katsuyuki; Ueshima, Hirotsugu; Kimura, Junko; Yatabe, Junichi

    2017-08-29

    The Na/K ratio is considered to be a useful index, the monitoring of which allows an effective Na reduction and K increase, because practical methods (self-monitoring devices and reliable individual estimates from spot urine) are available for assessing these levels in individuals. An intervention trial for lowering the Na/K ratio has demonstrated that a reduction of the Na/K ratio mainly involved Na reduction, with only a small change in K. The present study aimed to clarify the relationship between dietary Na intake and the urinary Na/K molar ratio, using standardized low- and high-salt diets, with an equal dietary K intake, to determine the corresponding Na/K ratio. Fourteen healthy young adult volunteers ingested low-salt (3 g salt per day) and high-salt (20 g salt per day) meals for seven days each. Using a portable urinary Na/K meter, participants measured their spot urine at each voiding, and 24-h urine was collected on the last day of each diet period. On the last day of the unrestricted, low-salt, and high-salt diet periods, the group averages of the 24-h urine Na/K ratio were 4.2, 1.0, and 6.9, while the group averages of the daily mean spot urine Na/K ratio were 4.2, 1.1, and 6.6, respectively. The urinary Na/K ratio tracked changes in dietary salt intake, and reached a plateau approximately three days after each change in diet. Frequent monitoring of the spot urine Na/K ratio may help individuals adhere to an appropriate dietary Na intake.

  12. Tamsulosin reduces nighttime urine production in benign prostatic hyperplasia patients with nocturnal polyuria: a prospective open-label long-term study using frequency-volume chart.

    PubMed

    Kojima, Yoshiyuki; Sasaki, Shoichi; Imura, Makoto; Kubota, Yasue; Hayashi, Yutaro; Kohri, Kenjiro

    2012-01-01

    The effects of tamsulosin treatment on changes in frequency-volume chart (FVC) data, especially nighttime urine production, over time were assessed, and the mechanisms underlying the improvement of nocturia in benign prostatic hyperplasia (BPH) patients with nocturnal polyuria (NP) are discussed. A total of 104 patients with lower urinary tract symptoms secondary to BPH were enrolled. After enrollment in the study, the patients were treated with tamsulosin (0.2 mg) once daily. Visits were scheduled every 4 weeks until week 12 (month 3) after study entry, and then every 12 weeks subsequently. All patients completed the International Prostate Symptom Score (IPSS), quality of life (QOL) index, and 3-day FVC, and underwent uroflowmetry at enrollment and on each visit. Eighty-two patients (mean age: 70.9 ± 7.1 years) were analyzed for 24 months after treatment. Patients were divided into two groups, NP and nonNP, based on FVC outcome. The IPSS, QOL index, and maximum flow rate improved during the 24-month period after treatment in both groups. Mean daytime urine volume significantly increased in the NP group, but no changes were detected in the nonNP group. Mean nighttime urine frequency significantly decreased in the NP group over a 24-month period, and was associated with a significant decrease in nighttime urine volume that was not found in the nonNP group. Maximum voided volume increased most months after treatment in both groups. The present long-term prospective study using FVC demonstrated that tamsulosin reduced nighttime urine production in BPH patients with NP. Copyright © 2011 Wiley Periodicals, Inc.

  13. Increasing fruits and vegetables in midlife women: a feasibility study.

    PubMed

    Gunn, Caroline A; Weber, Janet L; Coad, Jane; Kruger, Marlena C

    2013-07-01

    The positive link between bone health and fruit/vegetable consumption has been attributed to the lower renal acid load of a diet high in alkaline-forming fruit/vegetables. Other important dietary determinants of bone health include micronutrients and bioactives found in fruit/vegetables. We hypothesized that increased intake of fruit/vegetables to 9 or more servings a day would lower net endogenous acid production (NEAP) significantly (~20 mEq/d) and increase urine pH (0.5 pH units). This 8-week feasibility study investigated if 21 midlife women (age, 40-65 years) currently consuming 5 or less servings a day of fruit/vegetables could increase their intake to 9 or more servings a day to substantially lower NEAP and include specific vegetables daily. Three-day diet diaries were completed at baseline and the end of the study and assessed for NEAP (estimated) and number of servings from all food groups. Urine pH dipsticks were provided for the participants to assess and record their fasting urine pH daily (second void). Seventy-six percent of women achieved the study aim, which was to increase to 9 or more servings of fruit/vegetables for at least 5 d/wk. There was a reduction in the number of bread/cereal servings. Net endogenous acid production (estimated) was reduced significantly, with a mean urine pH increase of 0.68 pH units (95% confidence interval, 0.46-1.14); however, daily urine pH measures showed high variability. This study demonstrated that a group of midlife women can change their diet for 8 weeks by significantly increasing fruit/vegetable servings and include specific "bone friendly" vegetables daily, resulting in a significant decrease in estimated dietary NEAP and an increase in urine pH. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Evaluation of the BD Vacutainer Plus Urine C&S Preservative Tubes compared with nonpreservative urine samples stored at 4°C and room temperature.

    PubMed

    Eisinger, Stephen W; Schwartz, Matthew; Dam, Lisa; Riedel, Stefan

    2013-09-01

    The stability of urine specimens submitted for culture remains a challenge for many laboratories because of delays in specimen transport. We evaluated the usefulness of BD Vacutainer Plus Urine C&S Preservative Tube in ensuring specimen stability. Clinical urine specimens collected in sterile collection cups (n = 110) were plated onto sheep blood and MacConkey agar following standard laboratory procedures guidelines. Thereafter, specimens were divided into 3 storage conditions: nonpreservative, refrigerated; nonpreservative, room temperature (RT); BD Vacutainer Plus Urine C&S Preservative Tube, RT. For each sample type, additional cultures were set up at 2, 4, 24, and 48 hours. Initially, 18 specimens had no growth, 32 showed mixed skin flora, and 60 yielded at least 1 uropathogen. Increased colony counts of uropathogens were observed for nonpreserved urine samples stored at RT; these changes were statistically significant. Minor differences between refrigerated urine samples and BD Vacutainer Plus Urine C&S Preservative Tube samples were seen but were not statistically significant. The use of preservative-containing collection tubes is desirable to ensure specimen stability when prompt processing or refrigeration is not feasible.

  15. Partial bladder outlet obstruction induces urethral smooth muscle hypertrophy and decreased force generation.

    PubMed

    Hypolite, Joseph A; Chang, Shaohua; Zheng, Yongmu; DiSanto, Michael E; Zderic, Stephen A; Wein, Alan J; Chacko, Samuel

    2006-02-01

    PBOO leads to increased urinary frequency, decreased void volume, hypertrophy of the detrusor SM, and alterations in contractile and regulatory proteins. This study was done to determine whether PBOO induced increases in urinary frequency and detrusor SM hypertrophy are associated with an alteration in the contractility and expression of myosin isoforms in urethral SM. PBOO was surgically induced in male New Zealand White rabbits, and sham operated rabbits served as controls. After surgery, rabbits were kept 12 days, and prior to sacrifice, urine output and voiding frequency were monitored by keeping the animals in metabolic cages for 24 hours. Animals with increased urinary frequency (mean +/- SEM 43 +/- 12 voids per 24 hours) and sham operated rabbits (6 +/- 3 voids per 24 hours) were used for this study. Morphology of the urethra was studied using light and immunofluorescence microscopy. The expression of myosin isoforms was analyzed at the mRNA and protein levels by RT-PCR and Western blotting. The urethral wall and SM of PBOO rabbits showed hypertrophy. The force produced by the longitudinal muscle strips of PBOO animals in response to phenylephrine, KCl, or electrical field stimulation was decreased 50%, 37% and 40%, respectively. Immunofluorescence microscopy revealed a decrease in nerve density. RT-PCR and Western blotting showed a decrease in the expression of myosin isoform SM-B with a concomitant increase in SM-A at the mRNA and protein levels. Our data show hypertrophy of the urethral wall and SM, and alterations in contraction, innervation, and myosin isoforms in PBOO induced detrusor hypertrophy.

  16. Automated air-void system characterization of hardened concrete: Helping computers to count air-voids like people count air-voids---Methods for flatbed scanner calibration

    NASA Astrophysics Data System (ADS)

    Peterson, Karl

    Since the discovery in the late 1930s that air entrainment can improve the durability of concrete, it has been important for people to know the quantity, spacial distribution, and size distribution of the air-voids in their concrete mixes in order to ensure a durable final product. The task of air-void system characterization has fallen on the microscopist, who, according to a standard test method laid forth by the American Society of Testing and Materials, must meticulously count or measure about a thousand air-voids per sample as exposed on a cut and polished cross-section of concrete. The equipment used to perform this task has traditionally included a stereomicroscope, a mechanical stage, and a tally counter. Over the past 30 years, with the availability of computers and digital imaging, automated methods have been introduced to perform the same task, but using the same basic equipment. The method described here replaces the microscope and mechanical stage with an ordinary flatbed desktop scanner, and replaces the microscopist and tally counter with a personal computer; two pieces of equipment much more readily available than a microscope with a mechanical stage, and certainly easier to find than a person willing to sit for extended periods of time counting air-voids. Most laboratories that perform air-void system characterization typically have cabinets full of prepared samples with corresponding results from manual operators. Proponents of automated methods often take advantage of this fact by analyzing the same samples and comparing the results. A similar iterative approach is described here where scanned images collected from a significant number of samples are analyzed, the results compared to those of the manual operator, and the settings optimized to best approximate the results of the manual operator. The results of this calibration procedure are compared to an alternative calibration procedure based on the more rigorous digital image accuracy assessment methods employed primarily by the remote sensing/satellite imaging community.

  17. Effect of urine creatinine level during pregnancy on dipstick test.

    PubMed

    Baba, Yosuke; Furuta, Itsuko; Zhai, Tianyue; Ohkuchi, Akihide; Yamada, Takahiro; Takahashi, Kayo; Matsubara, Shigeki; Minakami, Hisanori

    2017-06-01

    Dipstick results for proteinuria are affected by urine concentration, and thus urine creatinine concentration ([Cr]). This study was performed to determine whether spot urine [Cr] changes significantly during pregnancy, leading to a significantly different false-negative rate (FNR) on dipstick test between trimester. The [Cr] and protein concentrations ([P]) were analyzed in 631 spot urine samples with negative/equivocal dipstick from 425 pregnant women. False-negative dipstick was defined as [P] : [Cr] ratio (P/Cr) > 0.27 mg/mg. Median [Cr] was 117 mg/dL (range, 6.5-326 mg/dL), 72 mg/dL (range, 4.3-477 mg/dL), and 73 mg/dL (range, 8.4-396 mg/dL) in the first (n = 96), second (n = 344), and third (n = 191) trimester urine samples, respectively (P = 0.000, Kruskal-Wallis). Both [P] and P/Cr increased significantly with advancing gestation. FNR 9.4% (18/191) in the third trimester was significantly higher than that of 0.0% (0/96) in the second trimester and that of 0.5% (2/344) in the third trimester. In the 20 urine samples with false-negative dipstick, median [Cr] was 47.0 mg/dL (range, 11.0-358 mg/dL) and the proportion of samples with dilute urine, that is, [Cr] <47 mg/dL, was significantly higher than in the remaining 611 urine samples (50%, 10/20 vs 28%, 174/611, respectively, P = 0.046). Urine samples in the second and third trimesters were more likely to be diluted compared with the first trimester. This was associated with high FNR in third trimester urine samples. © 2017 Japan Society of Obstetrics and Gynecology.

  18. A Spanner in the works: the use of a new temporary urethral stent to relieve bladder outflow obstruction after prostate brachytherapy.

    PubMed

    Henderson, Alastair; Laing, Robert W; Langley, Stephen E M

    2002-01-01

    Assessment of the Spanner, a new temporary urethral stent to relieve bladder outflow obstruction and urinary symptoms after brachytherapy. Five patients with unusually severe urinary morbidity after (125)I brachytherapy were recruited. The mean time after implant was 40 days (range 25-90). Spanner intraprostatic stents were introduced using topical anesthetic without complication. All patients were able to void spontaneously with no post-void residual volume of urine. The flow rates increased in all cases (p=0.03) and the International Prostate Symptom Scores were significantly improved after stent insertion in all patients (p=0.03). All patients experienced some degree of pain or dysuria during stent use. Bladder outflow obstruction was effectively treated with the Spanner intraprostatic stent, however pain limited the use of the device in the early post-brachytherapy patient group. Pharmacotherapy, stent design modification, or smaller stent diameter may increase the utility of stents after brachytherapy.

  19. Vesicoureteral Reflux in Kidney Transplantation.

    PubMed

    Molenaar, Nina M; Minnee, Robert C; Bemelman, Frederike J; Idu, Mirza M

    2017-06-01

    Vesicoureteral reflux (VUR) is frequently found after transplantation, but its impact on graft function, urine tract infection, and graft loss remains uncertain. Therefore our objective was to evaluate the effects of VUR on the outcome of renal transplantation. We included 1008 adult renal transplant recipients of whom a 1-week posttransplant voiding cystourethrogram was available. Study end points included occurrence of bacteriuria, renal function, and graft survival. In total, 106 (10.5%) of 1008 graft recipients had a diagnosis of VUR on voiding cystography. The incidence of bacteriuria was comparable in the reflux and nonreflux group (17% vs 17.4%, P = .91). There was no significant difference in renal function at 3 months and 1 year in patients with and without VUR. One- and 5-year graft survival in patients with VUR was 85.8% and 82.1% compared to 87.3% and 83.0% in patients without VUR ( P = .68 and P = .80). Posttransplant VUR has no correlations with early bacteriuria, renal function, and graft survival.

  20. Prevalence of urinary tract infection (UTI) in sequential acutely unwell children presenting in primary care: exploratory study.

    PubMed

    O'Brien, Kathryn; Stanton, Naomi; Edwards, Adrian; Hood, Kerenza; Butler, Christopher C

    2011-03-01

    Due to the non-specific nature of symptoms of UTI in children and low levels of urine sampling, the prevalence of UTI amongst acutely ill children in primary care is unknown. To undertake an exploratory study of acutely ill children consulting in primary care, determine the feasibility of obtaining urine samples, and describe presenting symptoms and signs, and the proportion with UTI. Exploratory, observational study. Four general practices in South Wales. A total of 99 sequential attendees with acute illness aged less than five years. UTI defined by >10(5) organisms/ml on laboratory culture of urine. Urine samples were obtained in 75 (76%) children. Three (4%) met microbiological criteria for UTI. GPs indicated they would not normally have obtained urine samples in any of these three children. However, all had received antibiotics for suspected alternative infections. Urine sample collection is feasible from the majority of acutely ill children in primary care, including infants. Some cases of UTI may be missed if children thought to have an alternative site of infection are excluded from urine sampling. A larger study is needed to more accurately determine the prevalence of UTI in children consulting with acute illness in primary care, and to explore which symptoms and signs might help clinicians effectively target urine sampling.

  1. Critical study of common conditions of storage of glucocorticoids and catecholamines in 24-h urine collected during resting and exercising conditions.

    PubMed

    Gouarne, C; Foury, A; Duclos, M

    2004-10-01

    Except immediate freezing of the samples, no practical method has been validated for preservation of glucocorticoids and catecholamines in 24-h urine collection. Furthermore, the influence of urine storage at bladder temperature during periods of different lengths and the effect of prior exercise on preservation of these hormones in the bladder have not been investigated until now. Ten healthy volunteers collected their urine both after a resting and after an exercise session. Urine was aliquoted into tubes which were stored during 24 h in the presence or in the absence of preservatives and at different temperatures. Two samples were stored either 3 or 9 h at 37 degrees C (bladder temperature) without additive. When collecting 24-h urine samples for glucocorticoids determination, sample can be stored at room temperature during the 24-h collection period without compromising glucocorticoids preservation. When collecting 24-h urine samples for catecholamines determination, samples have to be chilled without preservative during the whole of the collection period. If the samples have to be stored at room temperature, HCl should be used. Moreover, we report for the first time that catecholamines can be degraded in the bladder and therefore that subjects should urinate every 3 h during either a resting or an exercising day.

  2. Long-Term Frozen Storage of Urine Samples: A Trouble to Get PCR Results in Schistosoma spp. DNA Detection?

    PubMed Central

    Fernández-Soto, Pedro; Velasco Tirado, Virginia; Carranza Rodríguez, Cristina; Pérez-Arellano, José Luis; Muro, Antonio

    2013-01-01

    Background Human schistosomiasis remains a serious worldwide public health problem. At present, a sensitive and specific assay for routine diagnosis of schistosome infection is not yet available. The potential for detecting schistosome-derived DNA by PCR-based methods in human clinical samples is currently being investigated as a diagnostic tool with potential application in routine schistosomiasis diagnosis. Collection of diagnostic samples such as stool or blood is usually difficult in some populations. However, urine is a biological sample that can be collected in a non-invasive method, easy to get from people of all ages and easy in management, but as a sample for PCR diagnosis is still not widely used. This could be due to the high variability in the reported efficiency of detection as a result of the high variation in urine samples’ storage or conditions for handling and DNA preservation and extraction methods. Methodology/Principal Findings We evaluate different commercial DNA extraction methods from a series of long-term frozen storage human urine samples from patients with parasitological confirmed schistosomiasis in order to assess the PCR effectiveness for Schistosoma spp. detection. Patientś urine samples were frozen for 18 months up to 7 years until use. Results were compared with those obtained in PCR assays using fresh healthy human urine artificially contaminated with Schistosoma mansoni DNA and urine samples from mice experimentally infected with S. mansoni cercariae stored frozen for at least 12 months before use. PCR results in fresh human artificial urine samples using different DNA based extraction methods were much more effective than those obtained when long-term frozen human urine samples were used as the source of DNA template. Conclusions/Significance Long-term frozen human urine samples are probably not a good source for DNA extraction for use as a template in PCR detection of Schistosoma spp., regardless of the DNA method of extraction used. PMID:23613907

  3. Biological characteristics of human-urine-derived stem cells: potential for cell-based therapy in neurology.

    PubMed

    Guan, Jun-Jie; Niu, Xin; Gong, Fei-Xiang; Hu, Bin; Guo, Shang-Chun; Lou, Yuan-Lei; Zhang, Chang-Qing; Deng, Zhi-Feng; Wang, Yang

    2014-07-01

    Stem cells in human urine have gained attention in recent years; however, urine-derived stem cells (USCs) are far from being well elucidated. In this study, we compared the biological characteristics of USCs with adipose-derived stem cells (ASCs) and investigated whether USCs could serve as a potential cell source for neural tissue engineering. USCs were isolated from voided urine with a modified culture medium. Through a series of experiments, we examined the growth rate, surface antigens, and differentiation potential of USCs, and compared them with ASCs. USCs showed robust proliferation ability. After serial propagation, USCs retained normal karyotypes. Cell surface antigen expression of USCs was similar to ASCs. With lineage-specific induction factors, USCs could differentiate toward the osteogenic, chondrogenic, adipogenic, and neurogenic lineages. To assess the ability of USCs to survive, differentiate, and migrate, they were seeded onto hydrogel scaffold and transplanted into rat brain. The results showed that USCs were able to survive in the lesion site, migrate to other areas, and express proteins that were associated with neural phenotypes. The results of our study demonstrate that USCs possess similar biological characteristics with ASCs and have multilineage differentiation potential. Moreover USCs can differentiate to neuron-like cells in rat brain. The present study shows that USCs are a promising cell source for tissue engineering and regenerative medicine.

  4. Comparison of vacuum and non-vacuum urine tubes for urinary sediment analysis.

    PubMed

    Topcuoglu, Canan; Sezer, Sevilay; Kosem, Arzu; Ercan, Mujgan; Turhan, Turan

    2017-12-01

    Urine collection systems with aspiration system for vacuum tubes are becoming increasingly common for urinalysis, especially for microscopic examination of the urine. In this study, we aimed to examine whether vacuum aspiration of the urine sample has any adverse effect on sediment analysis by comparing results from vacuum and non-vacuum urine tubes. The study included totally 213 urine samples obtained from inpatients and outpatients in our hospital. Urine samples were collected to containers with aspiration system for vacuum tubes. Each sample was aliquoted to both vacuum and non-vacuum urine tubes. Urinary sediment analysis was performed using manual microscope. Results were evaluated using chi-square test. Comparison of the sediment analysis results from vacuum and non-vacuum urine tubes showed that results were highly concordant for erythrocyte, leukocyte and epithelial cells (gamma values 1, 0.997, and 0.994, respectively; p < .001). Results were also concordant for urinary casts, crystals and yeast (kappa values 0.815, 0.945 and 1, respectively; p < .001). The results show that in urinary sediment analysis, vacuum aspiration has no adverse effect on the cellular components except on casts.

  5. Clinical Significance of Prostatic Calculi: A Review

    PubMed Central

    2018-01-01

    Prostatic calculi often occur in middle-aged and old men. Prostatic calculi are usually classified as primary/endogenous stones or secondary/extrinsic stones. Endogenous stones are commonly caused by obstruction of the prostatic ducts around the enlarged prostate by benign prostatic hyperplasia (BPH) or by chronic inflammation. Extrinsic stones occur mainly around the urethra, because they are caused by urine reflux. The exact prevalence of prostatic calculi is not known, and it has been reported to vary widely, from 7% to 70%. Most cases of prostatic calculi are not accompanied by symptoms. Therefore, most cases are found incidentally during the diagnosis of BPH using transrectal ultrasonography (TRUS). However, prostatic calculi associated with chronic prostatitis may be accompanied by chronic pelvic pain. Rare cases have been reported in which extrinsic prostatic calculi caused by urine reflux have led to voiding difficulty due to their size. More than 80% of prostatic calculi are composed of calcium phosphate. Prostatic calculi can be easily diagnosed using TRUS or computed tomography. Treatment is often unnecessary, but if an individual experiences difficulty in urination or chronic pain, prostatic calculi can be easily removed using a transurethral electroresection loop or holmium laser. PMID:29076299

  6. Urine phenobarbital drug screening: potential use for compliance assessment in neonates.

    PubMed

    Guillet, Ronnie; Kwon, Jennifer M; Chen, Sixaio; McDermott, Michael P

    2012-02-01

    This study was done to determine if urine phenobarbital measurements provide a reliable indicator of presence of the drug in neonates. Urine was collected from neonates treated with phenobarbital for clinical indications within 4 to 6 hours of clinically indicated collection of serum phenobarbital levels. Urine samples were also collected from control neonates not treated with phenobarbital. One aliquot was assayed fresh, another frozen at -30°C and assayed 1 to 3 months later. Phenobarbital was assayed using the ONLINE TDM Roche/Hitachi automated clinical chemistry analyzer. Serum and urine concentrations were compared as were fresh and frozen urine measurements. Serum phenobarbital ranged from 5.6 to 52.7 μg/mL. Matched urine samples were 56.6 ± 12.5% of the serum level. Frozen samples were 98.3 ± 8.0% of the fresh samples. Urine phenobarbital concentrations, either fresh or frozen, can be used in neonates as a noninvasive estimate of drug levels.

  7. The effect of substrate composition and storage time on urine specific gravity in dogs.

    PubMed

    Steinberg, E; Drobatz, K; Aronson, L

    2009-10-01

    The purpose of this study is to evaluate the effects of substrate composition and storage time on urine specific gravity in dogs. A descriptive cohort study of 15 dogs. The urine specific gravity of free catch urine samples was analysed during a 5-hour time period using three separate storage methods; a closed syringe, a diaper pad and non-absorbable cat litter. The urine specific gravity increased over time in all three substrates. The syringe sample had the least change from baseline and the diaper sample had the greatest change from baseline. The urine specific gravity for the litter and diaper samples had a statistically significant increase from the 1-hour to the 5-hour time point. The urine specific gravity from canine urine stored either on a diaper or in a non-absorbable litter increased over time. Although the change was found to be statistically significant over the 5-hour study period it is unlikely to be clinically significant.

  8. Immunoelectrophoresis - urine

    MedlinePlus

    Immunoglobulin electrophoresis - urine; Gamma globulin electrophoresis - urine; Urine immunoglobulin electrophoresis; IEP - urine ... A clean-catch urine sample is needed. The clean-catch method is used to prevent germs from the penis or vagina from getting ...

  9. Disposition of acetaminophen in milk, saliva, and plasma of lactating women.

    PubMed

    Berlin, C M; Yaffe, S J; Ragni, M

    1980-01-01

    Acetaminophen (APAP) is a widely used analgesic and antipyretic, but its disposition in human milk has not yet been reported. Twelve nursing mothers (nursing two to 22 months) were given a single 650-mg peroral dose of APAP. Simultaneous saliva and milk samples were collected at zero, 1/4, 1/2, 3/4, 1, 2, 3, 5, 8, 12, and 24 hours after maternal dosing. In two mothers, plasma samples were also obtained at several points during the first six hours. Single voided urine samples were collected from the infants three to five hours after maternal dosing (two hours after nursing at peak maternal milk levels). All samples were assayed for APAP by high pressure liquid chromatography (HPCL) using a mobile phase of 0.05 M Na acetate pH 4.0-acetonitrile (93:10) with n-butyryl-p-aminophenol as the internal standard. APAP appeared in saliva and milk in the 1/4-hour samples; peak level (10-15 micrograms/ml) were achieved by one to two hours. Saliva/milk ratios during the elimination phase ranged from 0.7 to 1.1, with most values between 0.8 and 0.9. In two patients studied, saliva/plasma ratios were 0.9 to 1.0. Elimination phase t 1/2 (calculated from beta) ranged from 1.35 to 3.50 (x = 2.28 +/- SD 0.69) hours for milk, and from 1.72 to 3.30 (x = 2.48 +/- 0.56) hours for saliva. There was close agreement between saliva t 1/2 and milk t 1/2 for each patient. Assuming each infant ingested 90 ml milk at 3, 6, and 9 hours after maternal ingestion of APAP, the amount of APAP available for ingestion ranged from 0.28 to 1.51 mg (x = 0.88 +/- 0.31) or from 0.04% to 0.23% (x = 0.14 +/- 0.04) of maternal dose. Neither APAP nor metabolite was detected in nursing infants' urine. Maternal APAP ingestion in usual analgesic doses does not appear to present a risk to the nursing infant.

  10. Effect of condensed tannins in rations of lactating dairy cows on production variables and nitrogen use efficiency.

    PubMed

    Gerlach, K; Pries, M; Tholen, E; Schmithausen, A J; Büscher, W; Südekum, K-H

    2018-01-08

    The objective of this study was to evaluate the effect of supplemented condensed tannins (CT) from the bark of the Black Wattle tree (Acacia mearnsii) on production variables and N use efficiency in high yielding dairy cows. A feeding trial with 96 lactating German Holstein cows was conducted for a total of 169 days, divided into four periods. The animals were allotted to two groups (control (CON) and experimental (EXP) group) according to milk yield in previous lactation, days in milk (98), number of lactations and BW. The trial started and finished with a period (period 1 and 4) where both groups received the same ration (total-mixed ration based on grass and maize silage, ensiled sugar beet pulp, lucerne hay, mineral premix and concentrate, calculated for 37 kg energy-corrected milk). In between, the ration of EXP cows was supplemented with 1% (CT1, period 2) and 3% of dry matter (DM) (CT3, period 3) of a commercial A. mearnsii extract (containing 0.203 g CT/g DM) which was mixed into the concentrate. In period 3, samples of urine and faeces were collected from 10 cows of each group and analyzed to estimate N excretion. Except for a tendency for a reduced milk urea concentration with CT1, there was no difference between groups in period 2 (CON v. CT1; P>0.05). The CT3 significantly reduced (P<0.05) milk protein yield, the apparent N efficiency (kg milk N/k feed N) and milk urea concentration; but total milk yield and energy-corrected milk yield were not affected by treatment. Furthermore, as estimated from 10 cows per group and using urinary K as a marker to estimate the daily amount of urine voided, CT3 caused a minor shift of N compounds from urine to faeces, as urea-N in urine was reduced, whereas the N concentration in faeces increased. As an improvement in productivity was not achieved and N use efficiency was decreased by adding the CT product it can be concluded that under current circumstances the use in high yielding dairy cows is not advantageous.

  11. Consideration of the degree of increase in urine metadrenalines provides superior specificity in the diagnosis of phaeochromocytoma than additional urine catecholamine measurement.

    PubMed

    Scargill, J J; Reed, P; Kane, J

    2013-01-01

    Measurement of fractionated plasma or urine metadrenalines is the recommended screening test in the diagnosis of phaeochromocytoma, with clinical cut-offs geared towards diagnostic sensitivity. Current practice at Salford Royal Hospital is to add urine catecholamines onto samples with raised urine metadrenalines, with the aim of adding specificity to a diagnosis of phaeochromocytoma. This practice was reviewed by identifying a series of patients with raised urine metadrenalines who had catecholamines reflectively added. A total of 358 samples were identified from 242 patients, of which 228 had urine catecholamines measured. A diagnosis of 'phaeochromocytoma' (n = 41) or 'no phaeochromocytoma' (n = 90) was obtained in 131 of 228 patients, giving raised urine metadrenalines a positive predictive value for phaeochromocytoma of 31%. The finding of increased urine catecholamines in samples with raised urine metadrenalines increased specificity for phaeochromocytoma to 70%. However, 95% diagnostic specificity for phaeochromocytoma could be achieved by the introduction of a second cut-off for urine metadrenalines geared towards maximizing specificity. Consideration of the degree of increase in urine metadrenalines is a superior method of determining the likelihood of phaeochromocytoma than measurement of urine catecholamines.

  12. Importance of sample preparation for molecular diagnosis of lyme borreliosis from urine.

    PubMed

    Bergmann, A R; Schmidt, B L; Derler, A-M; Aberer, E

    2002-12-01

    Urine PCR has been used for the diagnosis of Borrelia burgdorferi infection in recent years but has been abandoned because of its low sensitivity and the irreproducibility of the results. Our study aimed to analyze technical details related to sample preparation and detection methods. Crucial for a successful urine PCR were (i) avoidance of the first morning urine sample; (ii) centrifugation at 36,000 x g; and (iii) the extraction method, with only DNAzol of the seven different extraction methods used yielding positive results with patient urine specimens. Furthermore, storage of frozen urine samples at -80 degrees C reduced the sensitivity of a positive urine PCR result obtained with samples from 72 untreated erythema migrans (EM) patients from 85% in the first 3 months to <30% after more than 3 months. Bands were detected at 276 bp on ethidium bromide-stained agarose gels after amplification by a nested PCR. The specificity of bands for 32 of 33 samples was proven by hybridization with a GEN-ETI-K-DEIA kit and for a 10 further positive amplicons by sequencing. By using all of these steps to optimize the urine PCR technique, B. burgdorferi infection could be diagnosed by using urine samples from EM patients with a sensitivity (85%) substantially better than that of serological methods (50%). This improved method could be of future importance as an additional laboratory technique for the diagnosis of unclear, unrecognized borrelia infections and diseases possibly related to Lyme borreliosis.

  13. Immunodetection and molecular determination of visceral and cutaneous Leishmania infection using patients' urine.

    PubMed

    Mirzaei, Asad; Ahmadipour, Fereshteh; Cannet, Arnaud; Marty, Pierre; Delaunay, Pascal; Perrin, Pascale; Dorkeld, Franck; Sereno, Denis; Akhoundi, Mohammad

    2018-05-27

    The diagnosis of leishmaniasis relies mainly on the use of invasive processes, to collect the biological material for detecting Leishmania parasites. Body fluids, which can be collected by non-invasive process, would greatly facilitate the leishmaniasis diagnosis. In the present study, we investigated the potency of urine immunoblotting to diagnose cutaneous and visceral leishmaniasis and we compared with routine molecular methods. A total of 80 samples, including 40 sera and their 40 corresponding urine samples were collected from 37 suspected patients with cutaneous and visceral leishmaniasis, and 3 healthy individuals (as control), in Ilam and Ardabil provinces of Iran. All sera and urine samples were analyzed, using immunoblotting. The confirmation of leishmaniasis infection was performed, using conventional and quantitative PCRs as well as by sequencing the amplicons. Among 37 suspected patients, 23 patients presented cutaneous lesions (CL) and 14 exhibited clinical symptoms reminiscent of visceral leishmaniasis (L. infantum). Among cutaneous patients, 15 were positive for zoonotic cutaneous leishmaniasis (L. major), and eight for anthroponotic cutaneous leishmaniasis (L. tropica). Molecular quantification of Leishmania parasites was performed on sera, urines and cutaneous biopsies of CL and VL patients, demonstrating that parasite load is lower in urines, compared to sera or biopsy. DNA can be detected in 20 out of 23 (86.9%) CL urine samples and in 13 out of 14 (92.8%) VL urine samples. Immunodetection analysis demonstrates that 22 out of 23 (95.6%) sera from CL patients and all patients suspected with VL are positive. For urine samples, 18 out of 23 (78.2%) urine of CL patients and 13 out of 14 (92.8%) urine of VL patients were positive, using Western blot. Therefore, immunodetection and molecular analysis using urine samples can be used as a diagnostic tool for surveying cutaneous and visceral leishmaniasis. Copyright © 2017. Published by Elsevier B.V.

  14. HCG in urine

    MedlinePlus

    Beta-HCG - urine; Human chorionic gonadotropin - urine; Pregnancy test - hCG in urine ... To collect a urine sample, you urinate into a special (sterile) cup. Home pregnancy tests require the test strip to be dipped into ...

  15. DNA methylation profiling of genomic DNA isolated from urine in diabetic chronic kidney disease: A pilot study

    PubMed Central

    Sexton-Oates, Alexandra; Carmody, Jake; Ekinci, Elif I.; Dwyer, Karen M.; Saffery, Richard

    2018-01-01

    Aim To characterise the genomic DNA (gDNA) yield from urine and quality of derived methylation data generated from the widely used Illuminia Infinium MethylationEPIC (HM850K) platform and compare this with buffy coat samples. Background DNA methylation is the most widely studied epigenetic mark and variations in DNA methylation profile have been implicated in diabetes which affects approximately 415 million people worldwide. Methods QIAamp Viral RNA Mini Kit and QIAamp DNA micro kit were used to extract DNA from frozen and fresh urine samples as well as increasing volumes of fresh urine. Matched buffy coats to the frozen urine were also obtained and DNA was extracted from the buffy coats using the QIAamp DNA Mini Kit. Genomic DNA of greater concentration than 20μg/ml were used for methylation analysis using the HM850K array. Results Irrespective of extraction technique or the use of fresh versus frozen urine samples, limited genomic DNA was obtained using a starting sample volume of 5ml (0–0.86μg/mL). In order to optimize the yield, we increased starting volumes to 50ml fresh urine, which yielded only 0–9.66μg/mL A different kit, QIAamp DNA Micro Kit, was trialled in six fresh urine samples and ten frozen urine samples with inadequate DNA yields from 0–17.7μg/mL and 0–1.6μg/mL respectively. Sufficient genomic DNA was obtained from only 4 of the initial 41 frozen urine samples (10%) for DNA methylation profiling. In comparison, all four buffy coat samples (100%) provided sufficient genomic DNA. Conclusion High quality data can be obtained provided a sufficient yield of genomic DNA is isolated. Despite optimizing various extraction methodologies, the modest amount of genomic DNA derived from urine, may limit the generalisability of this approach for the identification of DNA methylation biomarkers of chronic diabetic kidney disease. PMID:29462136

  16. DNA methylation profiling of genomic DNA isolated from urine in diabetic chronic kidney disease: A pilot study.

    PubMed

    Lecamwasam, Ashani; Sexton-Oates, Alexandra; Carmody, Jake; Ekinci, Elif I; Dwyer, Karen M; Saffery, Richard

    2018-01-01

    To characterise the genomic DNA (gDNA) yield from urine and quality of derived methylation data generated from the widely used Illuminia Infinium MethylationEPIC (HM850K) platform and compare this with buffy coat samples. DNA methylation is the most widely studied epigenetic mark and variations in DNA methylation profile have been implicated in diabetes which affects approximately 415 million people worldwide. QIAamp Viral RNA Mini Kit and QIAamp DNA micro kit were used to extract DNA from frozen and fresh urine samples as well as increasing volumes of fresh urine. Matched buffy coats to the frozen urine were also obtained and DNA was extracted from the buffy coats using the QIAamp DNA Mini Kit. Genomic DNA of greater concentration than 20μg/ml were used for methylation analysis using the HM850K array. Irrespective of extraction technique or the use of fresh versus frozen urine samples, limited genomic DNA was obtained using a starting sample volume of 5ml (0-0.86μg/mL). In order to optimize the yield, we increased starting volumes to 50ml fresh urine, which yielded only 0-9.66μg/mL A different kit, QIAamp DNA Micro Kit, was trialled in six fresh urine samples and ten frozen urine samples with inadequate DNA yields from 0-17.7μg/mL and 0-1.6μg/mL respectively. Sufficient genomic DNA was obtained from only 4 of the initial 41 frozen urine samples (10%) for DNA methylation profiling. In comparison, all four buffy coat samples (100%) provided sufficient genomic DNA. High quality data can be obtained provided a sufficient yield of genomic DNA is isolated. Despite optimizing various extraction methodologies, the modest amount of genomic DNA derived from urine, may limit the generalisability of this approach for the identification of DNA methylation biomarkers of chronic diabetic kidney disease.

  17. Trace Chemical Analysis Methodology

    DTIC Science & Technology

    1980-04-01

    oxidation of nitrite-containing species. Calibration studies were then made in preparation for the analysis of unknown samples of nitrate in urine and...the procedure for nitrate determination was made on two types of samples : human urine , and drinking water from a city water supply. Five samples of...AND URINE Concentration Standard Sample type of NO3, ppm deviation Drinking water 1.29 ±0 04 1.20 ±0.09 1.29 ±0.14 1.15 ±0.08 0.88 ±0.07 Human urine

  18. Effects of processing delay, temperature, and transport tube type on results of quantitative bacterial culture of canine urine.

    PubMed

    Patterson, Carly A; Bishop, Micah A; Pack, Julie D; Cook, Audrey K; Lawhon, Sara D

    2016-01-15

    To determine the impact of processing delay, temperature, and transport tube type on results of quantitative bacterial culture (QBC) of canine urine. Diagnostic test evaluation. 60 mL of pooled urine from 4 dogs, divided into six 10-mL aliquots. Urine aliquots were spiked with bacteria from 1 of 6 independent Escherichia coli cultures to achieve a target bacterial concentration of 10(5) CFUs/mL. One milliliter from each aliquot was transferred into 5 silicone-coated clot tubes (SCTs) and 5 urine transport tubes (UTTs). Samples were stored at 4°C (39°F) and 25°C (77°F) for 0, 8, and 24 hours, and then standard QBCs were performed. Median bacterial concentration for urine samples stored in a UTT for 24 hours at 4°C was lower than that for samples stored in an SCT under the same conditions. Conversely, a substantial decrease in median bacterial concentration was identified for samples stored for 24 hours in an SCT at 25°C, compared with the median concentration for samples stored in a UTT under the same conditions. Median bacterial concentration in samples stored in an SCT at 25°C for 24 hours (275 CFUs/mL) was less than the cutoff typically used to define clinically important bacteriuria by use of urine samples obtained via cystocentesis (ie, > 1,000 CFUs/mL). Canine urine samples submitted for immediate QBC should be transported in plain sterile tubes such as SCTs. When prolonged (24-hour) storage at room temperature is anticipated, urine samples should be transported in UTTs.

  19. Relationship between conventional culture and flow cytometry for the diagnosis of urinary tract infection.

    PubMed

    García-Coca, Marta; Gadea, Ignacio; Esteban, Jaime

    2017-06-01

    Urine culture is the gold standard for the diagnosis of urinary tract infections (UTI). The use of flow cytometry analyzers (FCA) prior to culture allows for the quantification and recognition of cell components in urine to be automated and makes it possible to relate these data to the urine pathogens subsequently identified in cultures. Urine samples were assessed with the Sysmex UF-1000i analyzer. Those that met the criteria for culture (> 25 leukocytes/μL or > 385 bacteria/μL) were subjected to quantitative urine culture on chromogenic agar. Counts of red blood cells (RBC), white blood cells (WBC), epithelial cells (EC), and the kind of microorganisms identified in cultures were evaluated. A total of 17,483 samples were processed by FCA. Of these, 9057 met the criteria for culture. Urine cultures were reduced by 48.2%. The most common urine pathogen was Escherichia coli (60.3%). Negative urine cultures were significantly (p < 0.001) associated with a lower WBC count than urine with E. coli, Klebsiella spp. and Proteus spp., but urine with Enterococcus spp. had a lower WBC than negative urine. Contaminated urine had a significantly (p < 0.001) lower WBC than urine with E. coli, Klebsiella spp. and Proteus spp., but no differences were found for Enterococcus spp. (p = 0.729). Negative urine cultures had significantly (p < 0.05) higher EC than all positive urine samples. Contaminated urine was associated (p < 0.001) with higher EC than cultures with E. coli and Klebsiella spp., in comparison with cultures with Enterococcus spp. (p = 0.091) and Proteus spp. (p = 0.251). The use of the Sysmex UF-1000i flow cytometer for screening urine samples allows for a reduction in the number of urine cultures. WBC values correlate well with the main urine pathogens related to UTI. The results observed for Enterococcus spp. suggest a low impact of these pathogens as a cause of UTI.

  20. Effects of Timing, Sex, and Age on Site-Specific Gastrointestinal Permeability Testing in Children and Adults

    PubMed Central

    McOmber, Mark E.; Ou, Ching-Nan; Shulman, Robert J.

    2010-01-01

    Summary Objectives Measurement of gastrointestinal (GI) permeability is used commonly in research and often clinically. Despite its utility, little is known about sugar excretion timeframes or the potential effects of age and gender in GI permeability testing. We sought to determine the timeframes of sugar excretion and the potential effects of age and gender on urinary recovery of the sugars. Methods Healthy adults (n=17) and children (n=15) fasted four hours after the evening meal and then ingested a solution of sucrose, lactulose, mannitol, and sucralose. Urine was collected at 30, 60, and 90 minutes after ingestion and then each time the subjects voided over the next 24 hr. Each urine void was collected separately. Results Median age for the adults was 47.5 yr. (range 21-57 yr.) and for children 10 yr. (5-17). There were no differences between children and adults in mean percent dose of sugar recovered. The time of peak urinary recovery of the sugars was generally similar between children and adults. Sucrose urinary recovery declined with age (P = 0.008; r2 = 0.19) unrelated to gender. Lactulose and sucralose urinary recovery declined with age in females (P = 0.05, r2 = 0.24 and P = 0.011, r2 = 0.41, respectively) but not in males. Conclusions Overall, sugar urinary recovery is comparable in children and adults. Specific sugar urinary recovery may change as a function of age and/or gender. These results need to be taken into account when planning and interpreting GI permeability studies. PMID:20081547

  1. Uroflowmetric assessment of acute effects of sildenafil on the voiding of men with erectile dysfunction and symptomatic benign prostatic hyperplasia.

    PubMed

    Guven, Esref O; Balbay, Mevlana D; Mete, Kilciler; Serefoglu, Ege C

    2009-01-01

    To evaluate the acute effects of sildenafil (50 mg) on the micturation of men with erectile dysfunction (ED) and concomitant benign prostatic hyperplasia (BPH) with lower urinary tract symptoms (LUTS) using uroflowmetric parameters. A total of 68 male patients randomized into two groups (36 treatment, 32 control groups) with International Prostate Symptom Score (IPSS) greater than 7 and International Index of Erectile Dysfunction-erectile function domain score lower than 26 were enrolled in the study. Patients in the treatment group received a single dose of 50 mg of oral sildenafil. Patients in the control group received no treatment. Prevoiding urine volumes determined ultrasonographically and voided urine volumes were also recorded. Statistical comparisons were made with the use of analysis of variance (ANOVA). Mean ages were similar between treatment and control groups (60.4 +/- 9.8 and 58.6 +/- 8.3 years, respectively, P = 0.430). In the treatment group the maximum and average flow rates increased significantly (Q (max) from 15.6 +/- 6.8 cc/s to 19.3 +/- 7.2 cc/s, P < 0.0001; Q (avg) from 7.3 +/- 3.0 cc/s to 9.1 +/- 3.0 cc/s, P < 0.0001) with sildenafil administration, while other parameters studied remained unchanged. Despite the limitations of variations of uroflowmetry, this study showed that sildenafil improves Q (max) and Q (avg) in patients suffering from ED with concomitant BPH-LUTS. Long-term studies are needed to evaluate the effects on IPSS, side effects, and drug interactions.

  2. Expanding our understanding of lower urinary tract symptoms and incontinence in adults with pompe disease.

    PubMed

    McNamara, Erin R; Austin, Stephanie; Case, Laura; Wiener, John S; Peterson, Andrew C; Kishnani, Priya S

    2015-01-01

    To study the prevalence of lower urinary tract symptoms (LUTS) and incontinence in late-onset Pompe disease (LOPD) Methods: Adult LOPD patients seen at the Duke Pompe Clinic were prospectively recruited and asked to complete validated questionnaires on LUTS and incontinence as part of an IRB-approved study. Patient demographics as well as previous urologic history were reviewed. 35 patients with LOPD were included in the study (17 males and 18 females). The median age was 51.8 (range 18-72 years of age). Of these patients, 27/35 were receiving enzyme replacement therapy (ERT) with median duration of 54 months (range 5-88 months). In the male patients, 9/17 (53%) described their stream as dribbling, weak, or intermittent, and 9/17 (53%) complained of post-void dribbling. In addition 38% of the men were unable to stop their urination midstream. In the female patients, the most common complaint was urinary incontinence, reported in 14/18 (78%). In addition, 7/18 (39%) complained of post-void dribbling, and 47% were unable to stop their urination midstream. Bowel incontinence was reported in 45% of patients. There was a significant association between urinary symptoms and lower extremity function scores and duration of ERT (p = 0.005 and p = 0.04, respectively) This is the first study in a large cohort of LOPD patients that demonstrates LUTS and incontinence occur at a high rate. This study emphasizes the spectrum of LOPD is beyond isolated gross motor and pulmonary involvement and has a significant effect on the lower urinary tract.

  3. Optimization of analytical and pre-analytical conditions for MALDI-TOF-MS human urine protein profiles.

    PubMed

    Calvano, C D; Aresta, A; Iacovone, M; De Benedetto, G E; Zambonin, C G; Battaglia, M; Ditonno, P; Rutigliano, M; Bettocchi, C

    2010-03-11

    Protein analysis in biological fluids, such as urine, by means of mass spectrometry (MS) still suffers for insufficient standardization in protocols for sample collection, storage and preparation. In this work, the influence of these variables on healthy donors human urine protein profiling performed by matrix assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was studied. A screening of various urine sample pre-treatment procedures and different sample deposition approaches on the MALDI target was performed. The influence of urine samples storage time and temperature on spectral profiles was evaluated by means of principal component analysis (PCA). The whole optimized procedure was eventually applied to the MALDI-TOF-MS analysis of human urine samples taken from prostate cancer patients. The best results in terms of detected ions number and abundance in the MS spectra were obtained by using home-made microcolumns packed with hydrophilic-lipophilic balance (HLB) resin as sample pre-treatment method; this procedure was also less expensive and suitable for high throughput analyses. Afterwards, the spin coating approach for sample deposition on the MALDI target plate was optimized, obtaining homogenous and reproducible spots. Then, PCA indicated that low storage temperatures of acidified and centrifuged samples, together with short handling time, allowed to obtain reproducible profiles without artifacts contribution due to experimental conditions. Finally, interesting differences were found by comparing the MALDI-TOF-MS protein profiles of pooled urine samples of healthy donors and prostate cancer patients. The results showed that analytical and pre-analytical variables are crucial for the success of urine analysis, to obtain meaningful and reproducible data, even if the intra-patient variability is very difficult to avoid. It has been proven how pooled urine samples can be an interesting way to make easier the comparison between healthy and pathological samples and to individuate possible differences in the protein expression between the two sets of samples. Copyright 2009 Elsevier B.V. All rights reserved.

  4. Long-term safety, tolerability, and efficacy of α1-adrenergic blocker in young men with primary bladder neck obstruction: results from a single centre in China.

    PubMed

    Li, Bing; Gao, Wansheng; Dong, Chuanjiang; Han, Xiaomin; Li, Shuqiang; Jia, Renfeng; Xiao, Chuanguo

    2012-06-01

    Primary bladder neck obstruction (PBNO) is a nonneurogenic voiding disorder and frequently overlooked in young men. Prior studies have reported the efficacy of α-blockers only in the short-term for male patients with PBNO. We hereby report our long-term results using α1-blocker therapy in young men with PBNO. Between January 2005 and December 2009, PBNO was diagnosed in 30 young men (mean age 27.3 years, range 18-35) at our institution. Doxazosin 4 mg once daily was administered for at least 12 months. Safety and tolerability were assessed, and efficacy was evaluated from International Prostate Symptom Score (I-PSS), Quality of Life (QOL), uroflowmetry, and post-void residual following 3- and 12-month treatment. Successful treatment was defined as at least 3 ml per second increase in the maximum flow rate and more than a 40% decrease in I-PSS. In all 30 patients, Mean symptom duration was 26.4 (3-65) months. The most common symptoms were hesitancy (93.3%), weak stream (76.7%), and frequency (66.7%). A total of 24 patients (80%, 24/30) successfully completed the 12 month of treatment. The medication period was 15.2 months, and follow-up duration was 16.3 months. Doxazosin was safe and well tolerated. The efficacy of doxazosin was maintained over the 12-month treatment period. Relative to baseline, there were reductions in the number of mean I-PSS (from 17.7 ± 4.2 to 10.4 ± 4.8), mean QOL (from 4.2 ± 1.1 to 2.4 ± 1.3), and mean post-void residual urine (from 79.3 ± 33.4 to 47.1 ± 21.3), and an increase in mean maximum flow rate (from 11.4 ± 2.9 to 15.1 ± 3.2 ml) after 12-month treatment. Treatment was successful in 16 patients (66.7%, 16/24) according to the improvement in both symptoms and maximum urine flow. α1-blocker therapy displayed a favorable safety, tolerability, and efficacy profile during 12-month treatment in young male patients with PBNO.

  5. Absence of bacterial DNA in culture-negative urine from cats with and without lower urinary tract disease.

    PubMed

    Lund, Heidi Sjetne; Skogtun, Gaute; Sørum, Henning; Eggertsdóttir, Anna Vigdís

    2015-10-01

    A diagnosis of bacterial cystitis commonly relies on a positive microbiological culture demonstrating the presence of a significant number of colony-forming units/ml urine, as urine within the upper urinary tract, bladder and proximal urethra generally is considered sterile. Recent studies from human and veterinary medicine indicate the presence of non-culturable bacteria in culture-negative urine samples. The aim of the present study was to determine the occurrence of bacterial DNA in culture-negative urine samples from cats with signs of feline lower urinary tract disease (FLUTD) and healthy control cats by 16S ribosomal DNA PCR and subsequent sequencing. The study sample included 38 culture-negative urine samples from cats with FLUTD and 43 culture-negative samples from control cats. Eight culture-positive urine samples from cats with FLUTD were included as external positive controls in addition to negative reaction controls. Of possible methodological limitations, degradation of DNA due to storage, the use of non-sedimented urine for DNA isolation and lack of internal positive reaction controls should be mentioned. The positive controls were recognised, but occurrence of bacterial DNA in culture-negative urine from cats with or without signs of lower urinary tract disease was not demonstrated. However, considering the possible methodological limitations, the presence of bacterial DNA in the urine of culture-negative FLUTD cats cannot be excluded based on the present results alone. Therefore, a prospective study reducing the possibility of degradation of DNA due to storage, in combination with modifications enhancing the chance of detecting even lower levels of bacterial DNA in culture-negative samples, seems warranted. © ISFM and AAFP 2014.

  6. Ex vivo spontaneous generation of 19-norandrostenedione and nandrolone detected in equine plasma and urine.

    PubMed

    Guan, Fuyu; Uboh, Cornelius E; Soma, Lawrence R; You, Youwen; Li, Xiaoqing; McDonnell, Sue

    2012-01-01

    19-Norandrostenedione (NAED) and nandrolone are anabolic-androgenic steroids (AASs). Nandrolone was regarded solely as a synthetic AAS until the 1980s when trace concentrations of apparently endogenous nandrolone were detected in urine samples obtained from intact male horses (stallions). Since then, its endogenous origin has been reported in boars and bulls; endogenous NAED and nandrolone have been identified in plasma and urine samples collected from stallions. More recently, however, it was suggested that NAED and nandrolone detected in urine samples from stallions are primarily artifacts due to the analytical procedure. The present study was undertaken to determine whether NAED and nandrolone detected in plasma and urine samples collected from stallions are truly endogenous or artifacts from sample processing. To answer this question, fresh plasma and urine samples from ≥8 stallions were analyzed for the two AASs, soon after collection, by liquid chromatography hyphenated to tandem mass spectrometry (LC-MS/MS). NAED and nandrolone were not detected in fresh plasma samples but detected in the same samples post storage. Concentrations of both AASs increased with storage time, and the increases were greater at a higher storage temperature (37°C versus 4°C, and ambient temperature versus 4°C). Although NAED was detected in some fresh stallion urine samples, its concentration (<407 pg/mL) was far lower (<0.4%) than that in the same samples post storage (at ambient temperature for 15 days). Nandrolone was not detected in most of fresh urine samples but detected in the same samples post storage. Based on these results, it is concluded that all NAED and nandrolone detected in stored plasma samples of stallions and most of them in the stored urine samples are not from endogenous origins but spontaneously generated during sample storage, most likely from spontaneous decarboxylation of androstenedione-19-oic acid and testosterone-19-oic acid. To our knowledge, it is the first time that all NAED and nandrolone detected in plasma of stallions and most of them detected in the urine have been shown to be spontaneously generated in vitro during sample storage. This finding would have significant implications with regard to the regulation of the two steroids in horse racing. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. The effectiveness of transcutaneous electrical neural stimulation therapy in patients with urinary incontinence resistant to initial medical treatment or biofeedback.

    PubMed

    Tugtepe, H; Thomas, D T; Ergun, R; Kalyoncu, A; Kaynak, A; Kastarli, C; Dagli, T E

    2015-06-01

    While there are many options for children with treatment refractory urinary incontinence, there is no single accepted method. This study's aim was to prospectively evaluate the effect of transcutaneous electrical nerve stimulation in children with urinary incontinence resistant to standard medical, urological therapy and/or biofeedback. This study was performed at a university hospital. For inclusion, patients >5 years of age first underwent evaluation with urinary ultrasonography, uroflow-electromyogram and voiding diaries. Treatment with biofeedback, alpha adrenergic blockers, anticholinergics and/or urotherapy was commenced according to uroflow-EMG and voiding diary findings. Patients with partial or no response to this standard therapy were then included in this study, performed between April 2012 and February 2014. Patients with anatomical or neurological causes for urinary incontinence were excluded. TENS was performed on S3 dermatome, every day for 3 months. Each session lasted 20 min with a frequency of 10 Hz and generated pulse of 350 μs. Intensity was determined by the child's sensitivity threshold. Medical treatment and urological therapy was continued during TENS. Uroflow parameters (voiding volume as percentage of expected bladder capacity, Qmax, Qave, flow and voiding time, postvoiding residual urine) and urinary system symptoms (presence of urinary tract infection, frequency, urge incontinence, fractionated voiding and constipation) were compared immediately before commencement and immediately after the completion of 3 months of TENS. Twenty-seven patients were included in this study (4 males, 23 females). Patients' average age was 7.2 years, 11 had overactive bladder and 16 had dysfunctional voiding. Comparison of urinary system symptoms and uroflow parameters before and after TENS are shown in Table. After 3 months of TENS; a statistically significant decrease was observed in the number of patients with frequency, urge incontinence, urinary tract infections and constipation. There was a decrease in the number of patients with fractionated voiding, although this change was not statistically significant. Similarly, for uroflow-EMG parameters; bladder capacity, Qmax, Qave and flow time increased while voiding time and PVR decreased. Changes seen in bladder capacity, Qmax and PVR were statically significant, while other changes were not. Patients' response rates after 3 months of TENS were; complete response in 70.4%, partial response in 22.2% and no response in 7.4%. This study has shown that transcutaneous electrical nerve stimulation is a promising treatment option for standard-treatment refractory children with urinary incontinence. Copyright © 2015 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  8. Calcium - urine

    MedlinePlus

    Urinary Ca+2; Kidney stones - calcium in urine; Renal calculi - calcium in your urine; Parathyroid - calcium in urine ... A 24-hour urine sample is most often needed: On day 1, urinate into the toilet when you wake up in the morning. ...

  9. Evaluation of Equations for Predicting 24-Hour Urinary Sodium Excretion from Casual Urine Samples in Asian Adults.

    PubMed

    Whitton, Clare; Gay, Gibson Ming Wei; Lim, Raymond Boon Tar; Tan, Linda Wei Lin; Lim, Wei-Yen; van Dam, Rob M

    2016-08-01

    The collection of 24-h urine samples for the estimation of sodium intake is burdensome, and the utility of spot urine samples in Southeast Asian populations is unclear. We aimed to assess the validity of prediction equations with the use of spot urine concentrations. A sample of 144 Singapore residents of Chinese, Malay, and Indian ethnicity aged 18-79 y were recruited from the Singapore Health 2 Study conducted in 2014. Participants collected urine for 24 h in multiple small bottles on a single day. To determine the optimal collection time for a spot urine sample, a 1-mL sample was taken from a random bottle collected in the morning, afternoon, and evening. Published equations and a newly derived equation were used to predict 24-h sodium excretion from spot urine samples. The mean ± SD concentration of sodium from the 24-h urine sample was 125 ± 53.4 mmol/d, which is equivalent to 7.2 ± 3.1 g salt. Bland-Altman plots showed good agreement at the group level between estimated and actual 24-h sodium excretion, with biases for the morning period of -3.5 mmol (95% CI: -14.8, 7.8 mmol; new equation) and 1.46 mmol (95% CI: -10.0, 13.0 mmol; Intersalt equation). A larger bias of 25.7 mmol (95% CI: 12.2, 39.3 mmol) was observed for the Tanaka equation in the morning period. The prediction accuracy did not differ significantly for spot urine samples collected at different times of the day or at a random time of day (P = 0.11-0.76). This study suggests that the application of both our own newly derived equation and the Intersalt equation to spot urine concentrations may be useful in predicting group means for 24-h sodium excretion in urban Asian populations. © 2016 American Society for Nutrition.

  10. Study of galaxies in the Lynx-Cancer void - VII. New oxygen abundances

    NASA Astrophysics Data System (ADS)

    Pustilnik, S. A.; Perepelitsyna, Y. A.; Kniazev, A. Y.

    2016-11-01

    We present new or improved oxygen abundances (O/H) for the nearby Lynx-Cancer void updated galaxy sample. They are obtained via the SAO 6-m telescope spectroscopy (25 objects), or derived from the Sloan Digital Sky Survey spectra (14 galaxies, of which for seven objects O/H values were unknown). For eight galaxies with detected [O III] λ4363 line, O/H values are derived via the direct (Te) method. For the remaining objects, O/H was estimated via semi-empirical and empirical methods. For all accumulated O/H data for 81 galaxies of this void (with 40 of them derived via Te method), their relation `O/H versus MB' is compared with that for similar late-type galaxies from denser environments (the Local Volume `reference sample'). We confirm our previous conclusion derived for a subsample of 48 objects: void galaxies show systematically reduced O/H for the same luminosity with respect to the reference sample, in average by 0.2 dex, or by a factor of ˜1.6. Moreover, we confirm the fraction of ˜20 per cent of strong outliers, with O/H of two to four times lower than the typical values for the `reference' sample. The new data are consistent with the conclusion on the slower evolution of the main void galaxy population. We obtained Hα velocity for the faint optical counterpart of the most gas-rich (M(H I)/LB = 25) void object J0723+3624, confirming its connection with the respective H I blob. For similar extremely gas-rich dwarf J0706+3020, we give a tentative O/H ˜(O/H)⊙/45. In Appendix A, we present the results of calibration of semi-empirical method by Izotov & Thuan and of empirical calibrators by Pilyugin & Thuan and Yin et al. on the sample of ˜150 galaxies from the literature with O/H measured by Te method.

  11. Urinary casts

    MedlinePlus

    ... tubular epithelial casts; Waxy casts; Casts in the urine; Fatty casts; Red blood cell casts; White blood ... The urine sample you provide may need to be from your first morning urine. The sample needs to be ...

  12. Urine Cytology

    MedlinePlus

    ... types of cells were found in your urine sample. You may need to repeat the test. Negative. This means no cancer cells were identified in your urine sample. Atypical. This indicates that some abnormalities were found ...

  13. Effect of Processing Delay and Storage Conditions on Urine Albumin-to-Creatinine Ratio.

    PubMed

    Herrington, William; Illingworth, Nicola; Staplin, Natalie; Kumar, Aishwarya; Storey, Ben; Hrusecka, Renata; Judge, Parminder; Mahmood, Maria; Parish, Sarah; Landray, Martin; Haynes, Richard; Baigent, Colin; Hill, Michael; Clark, Sarah

    2016-10-07

    Because there is substantial biologic intraindividual variation in albumin excretion, randomized trials of albuminuria-reducing therapies may need multiple urine samples to estimate daily urinary albumin excretion. Mailing spot urine samples could offer a convenient and cost-effective method to collect multiple samples, but urine albumin-to-creatinine ratio stability in samples stored at ambient temperatures for several days is unknown. Patients with kidney disease provided fresh urine samples in two tubes (with and without boric acid preservative). Reference aliquots from each participant were analyzed immediately, whereas remaining aliquots were subject to different handling/storage conditions before analysis, including delayed processing for up to 7 days at three different storage temperatures (4°C, 18°C, and 30°C), multiple freeze-thaw cycles, and long-term frozen storage at -80°C, -40°C, and -20°C. We calculated the mean percentage change in urine albumin-to-creatinine ratio for each condition, and we considered samples stable if the 95% confidence interval was within a ±5% threshold. Ninety-three patients provided samples with detectable albuminuria in the reference aliquot. Median (interquartile range) urine albumin-to-creatinine ratio was 87 (20-499) mg/g. The inclusion of preservative had minimal effect on fresh urine albumin-to-creatinine ratio measurements but reduced the changes in albumin and creatinine in samples subject to processing delay and storage conditions. The urine albumin-to-creatinine ratio was stable for 7 days in samples containing preservative at 4°C and 18°C and 2 days when stored at 30°C. It was also stable in samples with preservative after three freeze-thaw cycles and in frozen storage for 6 months at -80°C or -40°C but not at -20°C. Mailed urine samples collected with preservative and received within 7 days if ambient temperature is ≤18°C, or within 2 days if the temperature is higher but does not exceed 30°C, are suitable for the measurement of urine albumin-to-creatinine ratio in randomized trials. Preserved samples frozen to -40°C or -80°C for 6 months before analysis also seem suitable. Copyright © 2016 by the American Society of Nephrology.

  14. Effect of Processing Delay and Storage Conditions on Urine Albumin-to-Creatinine Ratio

    PubMed Central

    Illingworth, Nicola; Staplin, Natalie; Kumar, Aishwarya; Storey, Ben; Hrusecka, Renata; Judge, Parminder; Mahmood, Maria; Parish, Sarah; Landray, Martin; Haynes, Richard; Baigent, Colin; Hill, Michael; Clark, Sarah

    2016-01-01

    Background and objectives Because there is substantial biologic intraindividual variation in albumin excretion, randomized trials of albuminuria-reducing therapies may need multiple urine samples to estimate daily urinary albumin excretion. Mailing spot urine samples could offer a convenient and cost-effective method to collect multiple samples, but urine albumin-to-creatinine ratio stability in samples stored at ambient temperatures for several days is unknown. Design, setting, participants, & measurements Patients with kidney disease provided fresh urine samples in two tubes (with and without boric acid preservative). Reference aliquots from each participant were analyzed immediately, whereas remaining aliquots were subject to different handling/storage conditions before analysis, including delayed processing for up to 7 days at three different storage temperatures (4°C, 18°C, and 30°C), multiple freeze-thaw cycles, and long–term frozen storage at −80°C, −40°C, and −20°C. We calculated the mean percentage change in urine albumin-to-creatinine ratio for each condition, and we considered samples stable if the 95% confidence interval was within a ±5% threshold. Results Ninety-three patients provided samples with detectable albuminuria in the reference aliquot. Median (interquartile range) urine albumin-to-creatinine ratio was 87 (20–499) mg/g. The inclusion of preservative had minimal effect on fresh urine albumin-to-creatinine ratio measurements but reduced the changes in albumin and creatinine in samples subject to processing delay and storage conditions. The urine albumin-to-creatinine ratio was stable for 7 days in samples containing preservative at 4°C and 18°C and 2 days when stored at 30°C. It was also stable in samples with preservative after three freeze-thaw cycles and in frozen storage for 6 months at −80°C or −40°C but not at −20°C. Conclusions Mailed urine samples collected with preservative and received within 7 days if ambient temperature is ≤18°C, or within 2 days if the temperature is higher but does not exceed 30°C, are suitable for the measurement of urine albumin-to-creatinine ratio in randomized trials. Preserved samples frozen to −40°C or −80°C for 6 months before analysis also seem suitable. PMID:27654930

  15. The Urine Preservative Acetic Acid Degrades Urine Protein: Implications for Urine Biorepositories and the AASK Cohort Study

    PubMed Central

    Almaani, Salem; Hebert, Lee A.; Rovin, Brad H.

    2017-01-01

    Patients enrolled in the African American Study of Kidney Disease and Hypertension (AASK) Cohort Study who exhibited overt proteinuria have been reported to show high nonalbumin proteinuria (NAP), which is characteristic of a tubulopathy. To determine whether African American Study of Kidney Disease and Hypertension nephropathy (AASK-N) is a tubulopathy, we obtained urine samples of 37 patients with AASK-N, with 24-hour protein-to-creatinine ratios (milligrams per milligram) ranging from 0.2 to 1.0, from the National Institute of Diabetes and Digestive Kidney Diseases repository and tested for seven markers of tubular proteinuria. By protocol, each sample had been collected in acetic acid (0.5%; mean final concentration). Compared with samples from patients with lupus nephritis or healthy black controls, AASK-N samples had lower amounts of six markers. Four markers (albumin, β-2-microglobulin, cystatin C, and osteopontin) were undetectable in most AASK-N samples. Examination by SDS-PAGE followed by protein staining revealed protein profiles indicative of severe protein degradation in 34 of 37 AASK-N urine samples. Treatment of lupus nephritis urine samples with 0.5% acetic acid produced the same protein degradation profile as that of AASK-N urine. We conclude that the increased NAP in AASK-N is an artifact of acetic acid–mediated degradation of albumin. The AASK-N repository urine samples have been compromised by the acetic acid preservative. PMID:28104821

  16. The Urine Preservative Acetic Acid Degrades Urine Protein: Implications for Urine Biorepositories and the AASK Cohort Study.

    PubMed

    Almaani, Salem; Hebert, Lee A; Rovin, Brad H; Birmingham, Daniel J

    2017-05-01

    Patients enrolled in the African American Study of Kidney Disease and Hypertension (AASK) Cohort Study who exhibited overt proteinuria have been reported to show high nonalbumin proteinuria (NAP), which is characteristic of a tubulopathy. To determine whether African American Study of Kidney Disease and Hypertension nephropathy (AASK-N) is a tubulopathy, we obtained urine samples of 37 patients with AASK-N, with 24-hour protein-to-creatinine ratios (milligrams per milligram) ranging from 0.2 to 1.0, from the National Institute of Diabetes and Digestive Kidney Diseases repository and tested for seven markers of tubular proteinuria. By protocol, each sample had been collected in acetic acid (0.5%; mean final concentration). Compared with samples from patients with lupus nephritis or healthy black controls, AASK-N samples had lower amounts of six markers. Four markers (albumin, β -2-microglobulin, cystatin C, and osteopontin) were undetectable in most AASK-N samples. Examination by SDS-PAGE followed by protein staining revealed protein profiles indicative of severe protein degradation in 34 of 37 AASK-N urine samples. Treatment of lupus nephritis urine samples with 0.5% acetic acid produced the same protein degradation profile as that of AASK-N urine. We conclude that the increased NAP in AASK-N is an artifact of acetic acid-mediated degradation of albumin. The AASK-N repository urine samples have been compromised by the acetic acid preservative. Copyright © 2017 by the American Society of Nephrology.

  17. Spectra of galaxies in the Case Low-Dispersion Sky Survey in the direction of the Bootes void

    NASA Technical Reports Server (NTRS)

    Weistrop, Donna; Downes, Ronald A.

    1988-01-01

    A sample of 34 galaxies selected from the Case Low-Dispersion Northern Sky Survey in the direction of the Bootes void. Emission-line redshifts were obtained for 33 objects; the spectrum of the thirty-fourth galaxy contains no obvious features. Three of the emission-line galaxies are lcoated within the boundaries of the Bootes void, including one not previously reported. To date, all the galaxies discovered in the void have emission-line spectra. Although more than half the galaxies in the sample are fainter than M(B) = -21.0 mag, all five of the galaxies that were detected by IRAS are brighter than M(B) = 21.5 mag. The relative strengths of the emission lines in most of the galaxies, including those in the void, indicate the lines are excited by photoionization due to young, hot O and B stars. Possible causes for the star formation occurring in these galaxies include interaction with nearby galaxies, star formation induced by nuclear activity, and/or recent development of physical conditions required for star formation.

  18. Length of time domestic dogs (Canis familiaris) spend smelling urine of gonadectomised and intact conspecifics.

    PubMed

    Riach, Anna C; Asquith, Rachel; Fallon, Melissa L D

    2017-09-01

    Domestic dogs (Canis familiaris) use urine to communicate among themselves, however, it is unknown whether the gonadectomy (neutering or spaying) of a dog affects this communication in anyway. Urine samples from 10 intact and 10 gonadectomised, unfamiliar dogs were presented to 12 tester dogs to sniff under controlled conditions in a pilot study. The amount of time the tester dogs spent sniffing each sample was recorded. Overall, tester dogs were recorded smelling the urine of gonadectomised individuals for a longer time. In addition to the type of urine sample, the result is likely to have been influenced by the sex and status (gonadectomised or intact) of the tester dogs. The observed increase in the length of time spent sniffing urine from gonadectomised individuals could be explained by the tester dogs experiencing more difficulty in gaining information from the urine or facing more confusion while analysing the urine compared to the intact urine they have evolved to smell. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. The Impact of Using Different Methods to Assess Completeness of 24-Hour Urine Collection on Estimating Dietary Sodium.

    PubMed

    Wielgosz, Andreas; Robinson, Christopher; Mao, Yang; Jiang, Ying; Campbell, Norm R C; Muthuri, Stella; Morrison, Howard

    2016-06-01

    The standard for population-based surveillance of dietary sodium intake is 24-hour urine testing; however, this may be affected by incomplete urine collection. The impact of different indirect methods of assessing completeness of collection on estimated sodium ingestion has not been established. The authors enlisted 507 participants from an existing community study in 2009 to collect 24-hour urine samples. Several methods of assessing completeness of urine collection were tested. Mean sodium intake varied between 3648 mg/24 h and 7210 mg/24 h depending on the method used. Excluding urine samples collected for longer or shorter than 24 hours increased the estimated urine sodium excretion, even when corrections for the variation in timed collections were applied. Until an accurate method of indirectly assessing completeness of urine collection is identified, the gold standard of administering para-aminobenzoic acid is recommended. Efforts to ensure participants collect complete urine samples are also warranted. ©2015 Wiley Periodicals, Inc.

  20. Protein urine test

    MedlinePlus

    Urine protein; Albumin - urine; Urine albumin; Proteinuria; Albuminuria ... After you provide a urine sample, it is tested. The health care provider uses a dipstick made with a color-sensitive pad. The color change ...

  1. Detection of Circulating Paracoccidioides brasiliensis Antigen in Urine of Paracoccidioidomycosis Patients before and during Treatment

    PubMed Central

    Salina, Margarete Aparecida; Shikanai-Yasuda, Maria Aparecida; Mendes, Rinaldo Poncio; Barraviera, Benedito; Mendes Giannini, Maria José Soares

    1998-01-01

    For the diagnosis and follow-up of paracoccidioidomycosis patients undergoing therapy, we evaluated two methods (immunoblotting and competition enzyme immunoassay) for the detection of circulating antigen in urine samples. A complex pattern of reactivity was observed in the immunoblot test. Bands of 70 and 43 kDa were detected more often in urine samples from patients before treatment. The immunoblot method detected gp43 and gp70 separately or concurrently in 11 (91.7%) of 12 patients, whereas the competition enzyme immunoassay detected antigenuria in 9 (75%) of 12 patients. Both tests appeared to be highly specific (100%), considering that neither fraction detectable by immunoblotting was present in urine samples from the control group. gp43 remained present in the urine samples collected during the treatment period, with a significant decrease in reactivity in samples collected during clinical recovery and increased reactivity in samples collected during relapses. Reactivity of some bands was also detected in urine specimens from patients with “apparent cure.” The detection of Paracoccidioides brasiliensis antigens in urine appears to be a promising method for diagnosing infection, for evaluating the efficacy of treatment, and for detecting relapse. PMID:9620407

  2. Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode.

    PubMed

    Omar, Mohamed; Sarkissian, Carl; Jianbo, Li; Calle, Juan; Monga, Manoj

    2016-01-01

    To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode. We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the most recente pH result measured by dipstick from a spot urine sample that preceded the result of a 24-hour urine pH measured by the use of a pH electrode. Patients were excluded if there was a change in medications or dietary recommendations or if the two samples were more than 4 months apart. A difference of more than 0.5 pH was considered na inaccurate result. A total 600 patients were retrospectively reviewed for the pH results. The mean difference in pH between spot urine value and the 24 hours collection values was 0.52±0.45 pH. Higher pH was associated with lower accuracy (p<0.001). The accuracy of spot urine samples to predict 24-hour pH values of <5.5 was 68.9%, 68.2% for 5.5 to 6.5 and 35% for >6.5. Samples taken more than 75 days apart had only 49% the accuracy of more recent samples (p<0.002). The overall accuracy is lower than 80% (p<0.001). Influence of diurnal variation was not significant (p=0.588). Spot urine pH by dipstick is not an accurate method for evaluation of the patients with urolithiasis. Patients with alkaline urine are more prone to error with reliance on spot urine pH.

  3. Collection and storage of urine specimens for measurement of urolithiasis risk factors.

    PubMed

    Wu, Wenqi; Yang, Dong; Tiselius, Hans-Goran; Ou, Lili; Mai, Zanlin; Chen, Kang; Zhu, Hanliang; Xu, Shaohong; Zhao, Zhijian; Zeng, Guohua

    2015-02-01

    To evaluate how different methods for storage and preservation of urine samples affected the outcome of analysis of risk factors for stone formation. Spot urine samples were collected from 21 healthy volunteers. Each fresh urine sample was divided into ten 10-mL aliquots: 2 without preservative, 2 with thymol, 2 with toluene, 2 with hydrochloric acid (HCl), and 2 with sodium azide. One sample of each pair was stored at 4 °C and the other at room temperature. The concentrations of calcium, magnesium, sodium, phosphate, urate, oxalate, citrate, and pH in each urine sample were analyzed immediately after collection (0 hour) and after 24 and 48 hours. There were no significant differences in calcium, oxalate, magnesium, phosphate, sodium, urate or pH (without acidification) between samples with different preservation methods (P >.05). Urinary citrate, however, was significantly lower in the urine collected with HCl than when other preservatives were used, both at room temperature and at 4 °C. Urine pH was significantly higher after 48 hours than after 24 hours, whether the samples were stored at room temperature or at 4 °C. Antibacterial preservatives (eg, thymol or toluene) can be recommended as preservatives for 24-hour urine collections. Ideally, the samples should be stored at 4 °C. When HCl is used as a preservative, it seems essential to neutralize the samples before analysis. This is particularly obvious with the chromatographic method used for analysis of citrate that was used in this study. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Detection and genotyping of HPV in urine samples from Chilean women attending primary health care centers.

    PubMed

    Vergara, Nicolás; Balanda, Monserrat; Hidalgo, Wilma; Martín, Héctor San; Aceituno, Alexis; Roldán, Francisco; Villalón, Tania; Hott, Melissa; Espinoza, Gloria; Quiero, Andrea; Valenzuela, María T; Ramírez, Eugenio

    2018-04-01

    Cervical cancer is the second most common malignant neoplasm in women worldwide representing approximately 10% of all types of cancers. Triage of women through cervical cytology has been an important strategy for the surveillance and control of new cases of cervical cancer. However, in many regions around the world cervical cytology has a low coverage compared to developed countries. The molecular detection of HPV is the most effective method to increase the screening sensitivity of women at risk of developing cervical cancer. There are very few studies about the efficacy of urine testing for detection of HPV in women followed up in primary health care centers. Consequently, the efficacy of using urine HPV screening in these populations has not been addressed yet. Here, we compared the detection of HPV in simultaneous urine and cervical samples of women followed up in primary health care centers. Urine and cervical samples were analyzed in 543 women attending at primary health care centers. HPV was detected by real time PCR, and HPV typing performed by PCR-RLB. A general HPV concordance of 86.2% (κ = 0.72) was determined between urine and cervical samples. The concordance for HPV-16 and 18 was almost perfect (κ = 0.82) and strong (κ = 0.77), respectively. The sensitivity and specificity for all HPV genotypes in urine using cervical samples as reference were 82.1 and 93.7%, respectively. The results showed that urine is a good alternative as clinical sample for HPV screening in women attending primary health care centers. Therefore, urine should be used as an alternative sample for increasing triage coverage either in refractory women participating in Pap surveillance programs or when cervical samples are not available.

  5. Effect of a commercial anion dietary supplement on acid-base balance, urine volume, and urinary ion excretion in male goats fed oat or grass hay diets.

    PubMed

    Stratton-Phelps, Meri; House, John K

    2004-10-01

    To determine whether feeding a commercial anionic dietary supplement as a urinary acidifier to male goats may be useful for management of urolithiasis. 8 adult sexually intact male Toggenburg, Saanen, and Nubian goats. Goats were randomly assigned by age-, breed-, and weight-matched pairs to an oat or grass hay diet that was fed for 12 days. On days 13 to 14 (early sample collection time before supplementation), measurements were made of blood and urine sodium, potassium, calcium, magnesium, chloride, phosphorus, and sulfur concentrations; blood and urine pH; urine production; and water consumption. During the next 28 days, the anionic dietary supplement was added to the oat and grass hay diets to achieve a dietary cation-anion difference of 0 mEq/100g of dry matter. Blood and urine samples were analyzed during dietary supplementation on days 12 to 13 (middle sample collection time) and 27 to 28 (late sample collection time). Blood bicarbonate, pH, and urine pH of goats fed grass hay and goats fed oat hay were significantly decreased during the middle and late sample collection times, compared with the early sample collection time. Water consumption and urine production in all goats increased significantly during the late sample collection time, compared with the early sample collection time. The anionic dietary supplement used in our study increases urine volume, alters urine ion concentrations, and is an efficacious urinary acidifier in goats. Goats treated with prolonged anionic dietary supplementation should be monitored for secondary osteoporosis from chronic urinary calcium loss.

  6. Sample preparation and storage can change arsenic speciation in human urine.

    PubMed

    Feldmann, J; Lai, V W; Cullen, W R; Ma, M; Lu, X; Le, X C

    1999-11-01

    Stability of chemical speciation during sample handling and storage is a prerequisite to obtaining reliable results of trace element speciation analysis. There is no comprehensive information on the stability of common arsenic species, such as inorganic arsenite [As(III)], arsenate [As(V)], monomethylarsonic acid, dimethylarsinic acid, and arsenobetaine, in human urine. We compared the effects of the following storage conditions on the stability of these arsenic species: temperature (25, 4, and -20 degrees C), storage time (1, 2, 4, and 8 months), and the use of additives (HCl, sodium azide, benzoic acid, benzyltrimethylammonium chloride, and cetylpyridinium chloride). HPLC with both inductively coupled plasma mass spectrometry and hydride generation atomic fluorescence detection techniques were used for the speciation of arsenic. We found that all five of the arsenic species were stable for up to 2 months when urine samples were stored at 4 and -20 degrees C without any additives. For longer period of storage (4 and 8 months), the stability of arsenic species was dependent on urine matrices. Whereas the arsenic speciation in some urine samples was stable for the entire 8 months at both 4 and -20 degrees C, other urine samples stored under identical conditions showed substantial changes in the concentration of As(III), As(V), monomethylarsonic acid, and dimethylarsinic acid. The use of additives did not improve the stability of arsenic speciation in urine. The addition of 0.1 mol/L HCl (final concentration) to urine samples produced relative changes in inorganic As(III) and As(V) concentrations. Low temperature (4 and -20 degrees C) conditions are suitable for the storage of urine samples for up to 2 months. Untreated samples maintain their concentration of arsenic species, and additives have no particular benefit. Strong acidification is not appropriate for speciation analysis.

  7. NHEXAS PHASE I ARIZONA STUDY--METALS IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Urine data set contains analytical results for measurements of up to 6 metals in 176 urine samples over 176 households. Each sample was collected from the primary respondent within each household during Stage III of the NHEXAS study. The sample consists of the fir...

  8. Urine sampling and collection system

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Mangialardi, J. K.; Reinhardt, C. G.

    1971-01-01

    This specification defines the performance and design requirements for the urine sampling and collection system engineering model and establishes requirements for its design, development, and test. The model shall provide conceptual verification of a system applicable to manned space flight which will automatically provide for collection, volume sensing, and sampling of urine.

  9. Filter paper saturated by urine sample in metabolic disorders detection by proton magnetic resonance spectroscopy.

    PubMed

    Blasco, Hélène; Garrigue, Marie-Ange; De Vos, Aymeric; Antar, Catherine; Labarthe, François; Maillot, François; Andres, Christian R; Nadal-Desbarats, Lydie

    2010-02-01

    NMR spectroscopy of urine samples is able to diagnose many inborn errors of metabolism (IEM). However, urinary metabolites have a poor stability, requiring special care for routine analysis (storage of urine at -20 or -80 degrees C, fast transport). The aim of our study was to investigate the reliability of dried urine filter paper for urine storage and transport and to evaluate the ability of NMR to detect several IEM using this method. Urine samples from five healthy subjects were analyzed by (1)H NMR following different storage conditions (-20 vs 4 degrees C vs dried on filter paper) and at different time points (24 h, 48 h, 96 h, and 7 days). Urine pattern of fresh urine was considered as a reference. We analyzed the conservation of some amino acids and organic acids using Bland and Altman plot with intraclass correlation coefficient determination. Then, we evaluated the use of filter paper to detect four different IEM (methylmalonic and isovaleric acidurias, ornithine transcarbamylase deficiency, and cystinuria). Analysis of urine samples from healthy subjects revealed a high stability of studied molecules (ICC > 0.8) even after 7 days of storage on filter paper. Moreover, an excellent preservation of metabolites specifically accumulated in IEM was observed when analysis of dried urine filter paper was compared to fresh urine (coefficient of variation < 15%). This preliminary study demonstrates that storage of dried urine on filter paper is reliable for (1)H NMR spectroscopy analysis. Preservation of urine molecules over time using that method is convenient for routine clinical practice.

  10. Measurements of C-reactive protein (CRP) and nerve-growth-factor (NGF) concentrations in serum and urine samples of dogs with neurologic disorders.

    PubMed

    Kordass, Ulrike; Carlson, Regina; Stein, Veronika Maria; Tipold, Andrea

    2016-01-08

    The purpose of this study was to prove the hypothesis that C-reactive protein (CRP) and nerve growth factor (NGF) may be potential biomarkers for lower urinary tract disorders and may be able to distinguish between micturition dysfunctions of different origin in dogs with spinal cord diseases. NGF- and CRP- concentrations were measured in serum and urine samples using specific ELISA-Kits. Results in urine were standardized by urine-creatinine levels. CRP in serum was detectable in 32/76 and in urine samples in 40/76 patients. NGF could be measured in all serum and in 70/76 urine samples. Urinary CRP concentrations were significantly higher in dogs with micturition dysfunction (p = 0.0009) and in dogs with different neurological diseases (p = 0.0020) compared to the control group. However, comparing dogs with spinal cord disorders with and without associated micturition dysfunction no significant difference could be detected for NGF and CRP values in urine or serum samples. Additionally, levels did not decrease significantly, when measured at the time when the dogs regained the ability to urinate properly (urinary NGF p = 0.7962; urinary CRP p = 0.078). Urine samples with bacteria and/or leukocytes had no significant increase in urinary NGF (p = 0.1112) or CRP (p = 0.0534) concentrations, but higher CRP-levels in urine from dogs with cystitis were found compared to dogs without signs of cystitis. From these data we conclude that neither CRP nor NGF in urine or serum can be considered as reliable biomarkers for micturition disorders in dogs with spinal cord disorders in a clinical setting, but their production might be part of the pathogenesis of such disorders. Significantly higher levels of CRP could be found in the urine of dogs with micturition dysfunctions compared to control dogs. This phenomenon could potentially be explained by unspecific extrahepatic CRP production by smooth muscle cells in the dilated bladder.

  11. Prevalence of caffeine use in elite athletes following its removal from the World Anti-Doping Agency list of banned substances.

    PubMed

    Del Coso, Juan; Muñoz, Gloria; Muñoz-Guerra, Jesús

    2011-08-01

    The aim of this investigation was to determine the use of caffeine by athletes after its removal from the World Anti-Doping Agency list. For this purpose, we measured the caffeine concentration in 20 686 urine samples obtained for doping control from 2004 to 2008. We utilized only urine samples obtained after official national and international competitions. Urine caffeine concentration was determined using alkaline extraction followed by gas chromatography-mass spectrometry. The limit of detection (LOD) was set at 0.1 µg·mL(-1). The percentage of urine samples below the LOD was 26.2%; the remaining 73.8% of the urine samples contained caffeine. Most urine samples (67.3%) had urinary caffeine concentrations below 5 µg·mL(-1). Only 0.6% of urine samples exceeded the former threshold for caffeine doping (12 µg·mL(-1)). Triathlon (3.3 ± 2.2 µg·mL(-1)), cycling (2.6 ± 2.0 µg·mL(-1)), and rowing (1.9 ± 1.4 µg·mL(-1)) were the sports with the highest levels of urine caffeine concentration; gymnastics was the sport with the lowest urine caffeine concentration (0.5 ± 0.4 µg·mL(-1)). Older competitors (>30 y) had higher levels of caffeine in their urine than younger competitors (<20 y; p < 0.05); there were no differences between males and females. In conclusion, 3 out of 4 athletes had consumed caffeine before or during sports competition. Nevertheless, only a small proportion of these competitors (0.6%) had a urine caffeine concentration higher than 12 µg·mL(-1). Endurance sports were the disciplines showing the highest urine caffeine excretion after competition.

  12. Galaxy evolution in extreme environments: Molecular gas content star formation and AGN in isolated void galaxies

    NASA Astrophysics Data System (ADS)

    Das, Mousumi; Iono, Daisuke; Saito, Toshiki; Subramanian, Smitha

    Since the early redshift surveys of the large scale structure of our universe, it has become clear that galaxies cluster along walls, sheet and filaments leaving large, empty regions called voids between them. Although voids represent the most under dense parts of our universe, they do contain a sparse but significant population of isolated galaxies that are generally low luminosity, late type disk galaxies. Recent studies show that most void galaxies have ongoing star formation and are in an early stage of evolution. We present radio, optical studies of the molecular gas content and star formation in a sample of void galaxies. Using SDSS data, we find that AGN are rare in these systems and are found only in the Bootes void; their black hole masses and radio properties are similar to bright spirals galaxies. Our studies suggest that close galaxy interactions and gas accretion are the main drivers of galaxy evolution in these systems despite their location in the underdense environment of the voids.

  13. Quantifying voids effecting delamination in carbon/epoxy composites: static and fatigue fracture behavior

    NASA Astrophysics Data System (ADS)

    Hakim, I.; May, D.; Abo Ras, M.; Meyendorf, N.; Donaldson, S.

    2016-04-01

    On the present work, samples of carbon fiber/epoxy composites with different void levels were fabricated using hand layup vacuum bagging process by varying the pressure. Thermal nondestructive methods: thermal conductivity measurement, pulse thermography, pulse phase thermography and lock-in-thermography, and mechanical testing: modes I and II interlaminar fracture toughness were conducted. Comparing the parameters resulted from the thermal nondestructive testing revealed that voids lead to reductions in thermal properties in all directions of composites. The results of mode I and mode II interlaminar fracture toughness showed that voids lead to reductions in interlaminar fracture toughness. The parameters resulted from thermal nondestructive testing were correlated to the results of mode I and mode II interlaminar fracture toughness and voids were quantified.

  14. Trajectories of urinary incontinence in childhood and bladder and bowel symptoms in adolescence: prospective cohort study

    PubMed Central

    Heron, Jon; Grzeda, Mariusz T; von Gontard, Alexander; Wright, Anne; Joinson, Carol

    2017-01-01

    Objectives To identify different patterns (trajectories) of childhood urinary incontinence and examine which patterns are associated with bladder and bowel symptoms in adolescence. Design Prospective cohort study. Setting General community. Participants The starting sample included 8751 children (4507 men and 4244 women) with parent-reported data on frequency of bedwetting and daytime wetting for at least three of five time points (4½, 5½, 6½, 7½ and 9½ years—hereafter referred to as 4–9 years). Study children provided data on a range of bladder and bowel symptoms at age 14 (data available for 5899 participants). Outcome measures Self-reported bladder and bowel symptoms at 14 years including daytime wetting, bedwetting, nocturia, urgency, frequent urination, low voided volume, voiding postponement, passing hard stools and low stool frequency. Results We extracted 5 trajectories of urinary incontinence from 4 to 9 years using longitudinal latent class analysis: (1) normative development of daytime and night-time bladder control (63.0% of the sample), (2) delayed attainment of bladder control (8.6%), (3) bedwetting alone (no daytime wetting) (15.6%), (4) daytime wetting alone (no bedwetting) (5.8%) and (5) persistent wetting (bedwetting with daytime wetting to age 9) (7.0%). The persistent wetting class generally showed the strongest associations with the adolescent bladder and bowel symptoms: OR for bedwetting at 14 years=23.5, 95% CI (15.1 to 36.5), daytime wetting (6.98 (4.50 to 10.8)), nocturia (2.39 (1.79 to 3.20)), urgency (2.10 (1.44 to 3.07)) and passing hard stools (2.64 (1.63 to 4.27)) (reference category=normative development). The association with adolescent bedwetting was weaker for children with bedwetting alone (3.69 (2.21 to 6.17)). Conclusions Trajectories of childhood urinary incontinence are differentially associated with adolescent bladder and bowel symptoms. Children exhibiting persistent bedwetting with daytime wetting had the poorest outcomes in adolescence. PMID:28292756

  15. VizieR Online Data Catalog: A cosmic void catalog of SDSS DR12 BOSS galaxies (Mao+, 2017)

    NASA Astrophysics Data System (ADS)

    Mao, Q.; Berlind, A. A.; Scherrer, R. J.; Neyrinck, M. C.; Scoccimarro, R.; Tinker, J. L.; McBride, C. K.; Schneider, D. P.; Pan, K.; Bizyaev, D.; Malanushenko, E.; Malanushenko, V.

    2017-08-01

    We present a cosmic void catalog using the large-scale structure galaxy catalog from the Baryon Oscillation Spectroscopic Survey (BOSS). This galaxy catalog is part of the Sloan Digital Sky Survey (SDSS) Data Release 12 and is the final catalog of SDSS-III. We take into account the survey boundaries, masks, and angular and radial selection functions, and apply the ZOBOV (Neyrinck 2008MNRAS.386.2101N) void finding algorithm to the Galaxy catalog. We identify a total of 10643 voids. After making quality cuts to ensure that the voids represent real underdense regions, we obtain 1228 voids with effective radii spanning the range 20-100h-1Mpc and with central densities that are, on average, 30% of the mean sample density. We release versions of the catalogs both with and without quality cuts. We discuss the basic statistics of voids, such as their size and redshift distributions, and measure the radial density profile of the voids via a stacking technique. In addition, we construct mock void catalogs from 1000 mock galaxy catalogs, and find that the properties of BOSS voids are in good agreement with those in the mock catalogs. We compare the stellar mass distribution of galaxies living inside and outside of the voids, and find no large difference. These BOSS and mock void catalogs are useful for a number of cosmological and galaxy environment studies. (1 data file).

  16. Cosmic voids detection without density measurements

    NASA Astrophysics Data System (ADS)

    Elyiv, Andrii; Marulli, Federico; Pollina, Giorgia; Baldi, Marco; Branchini, Enzo; Cimatti, Andrea; Moscardini, Lauro

    2015-03-01

    Cosmic voids are effective cosmological probes to discriminate among competing world models. Their identification is generally based on density or geometry criteria that, because of their very nature, are prone to shot noise. We propose two void finders that are based on dynamical criterion to select voids in Lagrangian coordinates and minimize the impact of sparse sampling. The first approach exploits the Zel'dovich approximation to trace back in time the orbits of galaxies located in voids and their surroundings; the second uses the observed galaxy-galaxy correlation function to relax the objects' spatial distribution to homogeneity and isotropy. In both cases voids are defined as regions of the negative velocity divergence, which can be regarded as sinks of the back-in-time streamlines of the mass tracers. To assess the performance of our methods we used a dark matter halo mock catalogue CODECS, and compared the results with those obtained with the ZOBOV void finder. We find that the void divergence profiles are less scattered than the density ones and, therefore, their stacking constitutes a more accurate cosmological probe. The significance of the divergence signal in the central part of voids obtained from both our finders is 60 per cent higher than for overdensity profiles in the ZOBOV case. The ellipticity of the stacked void measured in the divergence field is closer to unity, as expected, than what is found when using halo positions. Therefore, our void finders are complementary to the existing methods, which should contribute to improve the accuracy of void-based cosmological tests.

  17. Ionic Liquid Dispersive Liquid-Liquid Microextraction Method for the Determination of Irinotecan, an Anticancer Drug, in Water and Urine Samples Using UV-Vis Spectrophotometry.

    PubMed

    Uysal, Deniz; Karadaş, Cennet; Kara, Derya

    2017-05-01

    A new, simple, efficient, and environmentally friendly ionic liquid dispersive liquid-liquid microextraction method was developed for the determination of irinotecan, an anticancer drug, in water and urine samples using UV-Vis spectrophotometry. The ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate was used as the extraction solvent, and ethanol was used as the disperser solvent. The main parameters affecting the extraction efficiency, including sample pH, volume of the ionic liquid, choice of the dispersive solvent and its volume, concentration of NaCl, and extraction and centrifugation times, were investigated and optimized. The effect of interfering species on the recovery of irinotecan was also examined. Under optimal conditions, the LOD (3σ) was 48.7 μg/L without any preconcentration. Because the urine sample was diluted 10-fold, the LOD for urine would be 487 μg/L. However, this could be improved 16-fold if preconcentration using a 40 mL aliquot of the sample is used. The proposed method was successfully applied to the determination of irinotecan in tap water, river water, and urine samples spiked with 10.20 mg/L for the water samples and 8.32 mg/L for the urine sample. The average recovery values of irinotecan determined were 99.1% for tap water, 109.4% for river water, and 96.1% for urine.

  18. Is a pre-analytical process for urinalysis required?

    PubMed

    Petit, Morgane; Beaudeux, Jean-Louis; Majoux, Sandrine; Hennequin, Carole

    2017-10-01

    For the reliable urinary measurement of calcium, phosphate and uric acid, a pre-analytical process by adding acid or base to urine samples at laboratory is recommended in order to dissolve precipitated solutes. Several studies on different kind of samples and analysers have previously shown that a such pre-analytical treatment is useless. The objective was to study the necessity of pre-analytical treatment of urine on samples collected using the V-Monovette ® (Sarstedt) system and measured on the analyser Architect C16000 (Abbott Diagnostics). Sixty urinary samples of hospitalized patients were selected (n=30 for calcium and phosphate, and n=30 for uric acid). After acidification of urine samples for measurement of calcium and phosphate, and alkalinisation for measurement of uric acid respectively, differences between results before and after the pre-analytical treatment were compared to acceptable limits recommended by the French society of clinical biology (SFBC). No difference in concentration between before and after pre-analytical treatment of urine samples exceeded acceptable limits from SFBC for measurement of calcium and uric acid. For phosphate, only one sample exceeded these acceptable limits, showing a result paradoxically lower after acidification. In conclusion, in agreement with previous study, our results show that acidification or alkalinisation of urine samples from 24 h urines or from urination is not a pre-analytical necessity for measurement of calcium, phosphate and uric acid.

  19. Effect of Marangoni Convection Generated by Voids on Segregation During Low-G and 1-G Solidification

    NASA Technical Reports Server (NTRS)

    Kassemi, M.; Fripp, A.; Rashidnia, N.; deGroh, H.

    2001-01-01

    Solidification experiments, especially microgravity solidification experiments, are often compromised by the evolution of unwanted voids or bubbles in the melt. Although these voids and/or bubbles are highly undesirable, there is currently no effective means of preventing their formation or of eliminating their adverse effects, particularly during microgravity experiments. Marangoni convection caused by these voids can drastically change the transport processes in the melt. Recent microgravity experiments by Matthiesen (1) Andrews (2) and Fripp (3) are perfect examples of how voids and bubbles can affect the outcome of costly space experiments and significantly increase the level of difficulty in interpreting their results. Formation of bubbles have caused problems in microgravity experiments for a long time. Even in the early Skylab mission an unexpectedly large number of bubbles were detected in the four materials processing experiments reported by Papazian and Wilcox (4). They demonstrated that while during ground-based tests bubbles were seen to detach from the interface easily and float to the top of the melt, in low-gravity tests no detachment from the interface occurred and large voids were grown in the crystal. More recently, the lead-tin-telluride crystal growth experiment of Fripp et al.(3) flown aboard the USMP-3 mission has provided very interesting results. The purpose of the study was to investigate the effect of natural convection on the solidification process by growing the samples at different orientations with respect to the gravitational field. Large pores and voids were found in the three solid crystal samples processed in space. Post-growth characterization of the compositional profiles of the cells indicated considerable levels of mixing even in the sample grown in the hot-on-top stable configuration. The mixing was attributed to thermocapillary convection caused by the voids and bubbles which evolved during growth. Since the thermocapillary convection is orientation-independent, diffusion-controlled growth was not possible in any of the samples, even the top-heated one. These results are consistent with recent studies of thermocapillary convection generated by a bubble on a heated surface undertaken by Kassemi and Rashidnia (5-7) where it is numerically and experimentally shown that the thermocapillary flow generated by a bubble in a model fluid (silicone oil) can drastically modify the temperature field through vigorous mixing of the fluid around it, especially under microgravity conditions.

  20. Effect of Selective Prostaglandin E2 EP2 Receptor Agonist CP-533,536 on Voiding Efficiency in Rats with Midodrine-Induced Functional Urethral Obstruction.

    PubMed

    Kurihara, Ryoko; Imazumi, Katsunori; Takamatsu, Hajime; Ishizu, Kenichiro; Yoshino, Taiji; Masuda, Noriyuki

    2016-05-01

    We investigated the effect of the selective prostaglandin E2 EP2 receptor agonist CP-533,536 on voiding efficiency in rats with midodrine-induced functional urethral obstruction. The effect of CP-533,536 (0.03-0.3 mg/kg, intravenous [i.v.]) on urethral perfusion pressure (UPP) was investigated in anesthetized rats pre-treated with midodrine (1 mg/kg, i.v.), which forms an active metabolite that acts as an α1 -adrenoceptor agonist. The effect of CP-533,536 (0.03-0.3 mg/kg, i.v.) on cystometric parameters was also investigated in anesthetized rats. In addition, the effect of CP-533,536 (0.03-0.3 mg/kg, i.v.) on residual urine volume (RV) and voiding efficiency (VE) was investigated in conscious rats treated with midodrine (1 mg/kg, i.v.). CP-533,536 dose-dependently decreased UPP elevated by midodrine in anesthetized rats. In contrast, CP-533,536 did not affect maximum voiding pressure, intercontraction interval, or intravesical threshold pressure. In conscious rats, midodrine (1 mg/kg, i.v.) markedly increased RV and reduced VE. CP-533,536 dose-dependently ameliorated increases in RV and decreases in VE induced by midodrine. These results suggest that a selective EP2 receptor agonist could ameliorate the elevation of RV and improve the reduction of VE in rats with functional urethral obstruction caused by stimulation of α1 -adrenoceptors. The mechanism of action might be not potentiation of bladder contraction but rather preferential relief of urethral constriction. © 2014 Wiley Publishing Asia Pty Ltd.

  1. Commuting behaviors and exposure to air pollution in Montreal, Canada.

    PubMed

    Miao, Qun; Bouchard, Michèle; Chen, Dongmei; Rosenberg, Mark W; Aronson, Kristan J

    2015-03-01

    Vehicular traffic is a major source of outdoor air pollution in urban areas, and studies have shown that air pollution is worse during hours of commuting to and from work and school. However, it is unclear to what extent different commuting behaviors are a source of air pollution compared to non-commuters, and if air pollution exposure actually differs by the mode of commuting. This study aimed to examine the relationships between commuting behaviors and air pollution exposure levels measured by urinary 1-OHP (1-hydroxypyrene), a biomarker of exposure to polycyclic aromatic hydrocarbons (PAHs). A cross-sectional study of 174 volunteers living in Montreal, 92 females and 82 males, aged 20 to 53 years was conducted in 2011. Each participant completed a questionnaire regarding demographic factors, commuting behaviors, home and workplace addresses, and potential sources of PAH exposure, and provided a complete first morning void urine sample for 1-OHP analysis. Multivariable general linear regression models were used to examine the relationships between different types of commuting and urinary 1-OHP levels. Compared to non-commuters, commuters traveling by foot or bicycle and by car or truck had a significantly higher urinary 1-OHP concentration in urine (p=0.01 for foot or bicycle vs. non-commuters; p=0.02 for car or truck vs. non-commuters); those traveling with public transportation and combinations of two or more types of modes tended to have an increased 1-OHP level in urine (p=0.06 for public transportation vs. non-commuters; p=0.05 for commuters with combinations of two or more types of modes vs. non-commuters). No significant difference in urinary 1-OHP variation was found by mode of commuting. This preliminary study suggests that despite the mode of commuting, all types of commuting during rush hours increase exposure to air pollution as measured by a sensitive PAH metabolite biomarker, and mode of commuting did not explain exposure variation. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. A C-terminal Aldehyde Analog of the Insect Kinins Inhibits Diuresis in the Housefly

    DTIC Science & Technology

    2006-09-21

    p e p t i d e s 2 8 ( 2 0 0 7 ) 1 4 6 – 1 5 2A C-terminal aldehyde analog of the insect kinins inhibits diuresis in the housefly Ronald J. Nachman a...secretion in crickets, but shows inhibition of both in vitro and in vivo diuresis in the housefly . R-LK-CHO reduced the total amount of urine voided over 3 h...from flies injected with 1 mL of distilled water by almost 50%. The analog not only inhibits stimulation of housefly fluid secretion by the native

  3. Urine sampling techniques in symptomatic primary-care patients: a diagnostic accuracy review.

    PubMed

    Holm, Anne; Aabenhus, Rune

    2016-06-08

    Choice of urine sampling technique in urinary tract infection may impact diagnostic accuracy and thus lead to possible over- or undertreatment. Currently no evidencebased consensus exists regarding correct sampling technique of urine from women with symptoms of urinary tract infection in primary care. The aim of this study was to determine the accuracy of urine culture from different sampling-techniques in symptomatic non-pregnant women in primary care. A systematic review was conducted by searching Medline and Embase for clinical studies conducted in primary care using a randomized or paired design to compare the result of urine culture obtained with two or more collection techniques in adult, female, non-pregnant patients with symptoms of urinary tract infection. We evaluated quality of the studies and compared accuracy based on dichotomized outcomes. We included seven studies investigating urine sampling technique in 1062 symptomatic patients in primary care. Mid-stream-clean-catch had a positive predictive value of 0.79 to 0.95 and a negative predictive value close to 1 compared to sterile techniques. Two randomized controlled trials found no difference in infection rate between mid-stream-clean-catch, mid-stream-urine and random samples. At present, no evidence suggests that sampling technique affects the accuracy of the microbiological diagnosis in non-pregnant women with symptoms of urinary tract infection in primary care. However, the evidence presented is in-direct and the difference between mid-stream-clean-catch, mid-stream-urine and random samples remains to be investigated in a paired design to verify the present findings.

  4. [Comparison of the Conventional Centrifuged and Filtrated Preparations in Urine Cytology].

    PubMed

    Sekita, Nobuyuki; Shimosakai, Hirofumi; Nishikawa, Rika; Sato, Hiroaki; Kouno, Hiroyoshi; Fujimura, Masaaki; Mikami, Kazuo

    2016-03-01

    The urine cytology test is one of the most important tools for the diagnosis of malignant urinary tract tumors. This test is also of great value for predicting malignancy. However, the sensitivity of this test is not high enough to screen for malignant cells. In our laboratory, we were able to attain a high sensitivity of urine cytology tests after changing the preparation method of urine samples. The differences in the cytodiagnosis between the two methods are discussed here. From January 2012 to June 2013, 2,031 urine samples were prepared using the conventional centrifuge method (C method) ; and from September 2013 to March 2015, 2,453 urine samples were prepared using the filtration method (F method) for the cytology test. When the samples included in category 4 or 5, were defined as cytological positive, the sensitivities of this test with samples prepared using the F method were significantly high compared with samples prepared using the C method (72% vs 28%, p<0.001). The number of cells on the glass slides prepared by the F method was significantly higher than that of the samples prepared by the C method (p<0.001). After introduction of the F method, the number of f alse negative cases was decreased in the urine cytology test because a larger number of cells was seen and easily detected as atypical or malignant epithelial cells. Therefore, this method has a higher sensitivity than the conventional C method as the sensitivity of urine cytology tests relies partially on the number of cells visualized in the prepared samples.

  5. An initial study of void formation during solidification of aluminum in normal and reduced-gravity

    NASA Technical Reports Server (NTRS)

    Chiaramonte, Francis P.; Foerster, George; Gotti, Daniel J.; Neumann, Eric S.; Johnston, J. C.; De Witt, Kenneth J.

    1992-01-01

    Void formation due to volumetric shrinkage during aluminum solidification was observed in real time using a radiographic viewing system in normal and reduced gravity. An end chill directional solidification furnace with water quench was developed to solidify aluminum samples during the approximately 16 seconds of reduced gravity (+/- 0.02g) achieved by flying an aircraft through a parabolic trajectory. Void formation was recorded for two cases: first a nonwetting system; and second, a wetting system where wetting occurs between the aluminum and crucible lid. The void formation in the nonwetting case is similar in normal and reduced gravity, with a single vapor cavity forming at the top of the crucible. In the wetting case in reduced gravity, surface tension causes two voids to form in the top corners of the crucible, but in normal gravity only one large voids forms across the top.

  6. Comparison of urine and bladder or urethral mucosal biopsy culture obtained by transurethral cystoscopy in dogs with chronic lower urinary tract disease: 41 cases (2002 to 2011).

    PubMed

    Sycamore, K F; Poorbaugh, V R; Pullin, S S; Ward, C R

    2014-07-01

    To compare aerobic bacterial culture of urine to cystoscopically obtained mucosal biopsies of the lower urinary tract in dogs. Retrospective review of case records from dogs that had transurethral cystoscopy at a veterinary teaching hospital between 2002 and 2011. Dogs that had culture results from cystocentesis obtained urine and transurethral cystoscopically obtained mucosal samples were included in the study. Pathogens identified were compared between sampling methods. Forty dogs underwent transurethral cystoscopy for lower urinary tract disease on 41 occasions. There was significant (P = 0 · 0003) agreement between urine and mucosal biopsy cultures. Both cultures were negative in 66% and positive in 17% of dogs. There was a 17% disagreement between the sampling methods. Although not statistically significant, more mucosal samples than urine cultures were positive for Escherichia coli. There was a good agreement between pathogen identification from urine and lower urinary tract mucosal cultures. These results do not support the utilisation of transurethral cystoscopy to obtain biopsy samples for culture in dogs with urinary tract infection and positive urine culture. Individual cases with possible chronic urinary tract infection and negative urine culture may benefit from transurethral cystoscopy to obtain biopsies for culture. © 2014 British Small Animal Veterinary Association.

  7. [Delayed testing for the diagnosis of fungi in the urines. Evaluation of the BD Vacutainer C&S tubes for the storage of urine samples at room temperature].

    PubMed

    Baixench, M T; Al-Sheikh, M; Paugam, A

    2005-01-01

    The study included 37 urine samples which have been artificially infected with low levels (10(3) CFU/mL) of various fungi strains. We compared the effects of sample storage, up to 48 hours, at room temperature, in a urine evacuated tube containing specific additives with storage at + 4 degrees C, for the same length of time, in a urine evacuated tube without any additives. There have been no differences of results (speed of growth and colony size) between the 2 modes of storage. However, the experience has shown that samples needed a careful mixing before seeding to avoid underdetection of the strains. Based on the study results, the BD Vacutainer C&S tubes are suitable for delayed testing for the diagnosis of urine fungal infection.

  8. Detection of human papillomavirus DNA in urine. A review of the literature.

    PubMed

    Vorsters, A; Micalessi, I; Bilcke, J; Ieven, M; Bogers, J; Van Damme, P

    2012-05-01

    The detection of human papillomavirus (HPV) DNA in urine, a specimen easily obtained by a non-invasive self-sampling method, has been the subject of a considerable number of studies. This review provides an overview of 41 published studies; assesses how different methods and settings may contribute to the sometimes contradictory outcomes; and discusses the potential relevance of using urine samples in vaccine trials, disease surveillance, epidemiological studies, and specific settings of cervical cancer screening. Urine sampling, storage conditions, sample preparation, DNA extraction, and DNA amplification may all have an important impact on HPV DNA detection and the form of viral DNA that is detected. Possible trends in HPV DNA prevalence in urine could be inferred from the presence of risk factors or the diagnosis of cervical lesions. HPV DNA detection in urine is feasible and may become a useful tool but necessitates further improvement and standardization.

  9. Urine Galactomannan-to-Creatinine Ratio for Detection of Invasive Aspergillosis in Patients with Hematological Malignancies.

    PubMed

    Reischies, Frederike M J; Raggam, Reinhard B; Prattes, Juergen; Krause, Robert; Eigl, Susanne; List, Agnes; Quehenberger, Franz; Strenger, Volker; Wölfler, Albert; Hoenigl, Martin

    2016-03-01

    Galactomannan (GM) testing of urine specimens may provide important advantages, compared to serum testing, such as easy noninvasive sample collection. We evaluated a total of 632 serial urine samples from 71 patients with underlying hematological malignancies and found that the urine GM/creatinine ratio, i.e., (urine GM level × 100)/urine creatinine level, which takes urine dilution into account, reliably detected invasive aspergillosis and may be a promising diagnostic tool for patients with hematological malignancies. (This study has been registered at ClinicalTrials.gov under registration no. NCT01576653.). Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  10. Effects of storage time and temperature on pH, specific gravity, and crystal formation in urine samples from dogs and cats.

    PubMed

    Albasan, Hasan; Lulich, Jody P; Osborne, Carl A; Lekcharoensuk, Chalermpol; Ulrich, Lisa K; Carpenter, Kathleen A

    2003-01-15

    To determine effects of storage temperature and time on pH and specific gravity of and number and size of crystals in urine samples from dogs and cats. Randomized complete block design. 31 dogs and 8 cats. Aliquots of each urine sample were analyzed within 60 minutes of collection or after storage at room or refrigeration temperatures (20 vs 6 degrees C [68 vs 43 degrees F]) for 6 or 24 hours. Crystals formed in samples from 11 of 39 (28%) animals. Calcium oxalate (CaOx) crystals formed in vitro in samples from 1 cat and 8 dogs. Magnesium ammonium phosphate (MAP) crystals formed in vitro in samples from 2 dogs. Compared with aliquots stored at room temperature, refrigeration increased the number and size of crystals that formed in vitro; however, the increase in number and size of MAP crystals in stored urine samples was not significant. Increased storage time and decreased storage temperature were associated with a significant increase in number of CaOx crystals formed. Greater numbers of crystals formed in urine aliquots stored for 24 hours than in aliquots stored for 6 hours. Storage time and temperature did not have a significant effect on pH or specific gravity. Urine samples should be analyzed within 60 minutes of collection to minimize temperature- and time-dependent effects on in vitro crystal formation. Presence of crystals observed in stored samples should be validated by reevaluation of fresh urine.

  11. Multiplexed Microsphere Suspension-Array Assay for Urine Mitochondrial DNA Typing by C-Stretch Length in Hypervariable Regions.

    PubMed

    Aoki, Kimiko; Tanaka, Hiroyuki; Kawahara, Takashi

    2018-07-01

    The standard method for personal identification and verification of urine samples in doping control is short tandem repeat (STR) analysis using nuclear DNA (nDNA). The DNA concentration of urine is very low and decreases under most conditions used for sample storage; therefore, the amount of DNA from cryopreserved urine samples may be insufficient for STR analysis. We aimed to establish a multiplexed assay for urine mitochondrial DNA typing containing only trace amounts of DNA, particularly for Japanese populations. A multiplexed suspension-array assay using oligo-tagged microspheres (Luminex MagPlex-TAG) was developed to measure C-stretch length in hypervariable region 1 (HV1) and 2 (HV2), five single nucleotide polymorphisms (SNPs), and one polymorphic indel. Based on these SNPs and the indel, the Japanese population can be classified into five major haplogroups (D4, B, M7a, A, D5). The assay was applied to DNA samples from urine cryopreserved for 1 - 1.5 years (n = 63) and fresh blood (n = 150). The assay with blood DNA enabled Japanese subjects to be categorized into 62 types, exhibiting a discriminatory power of 0.960. The detection limit for cryopreserved urine was 0.005 ng of nDNA. Profiling of blood and urine pairs revealed that 5 of 63 pairs showed different C-stretch patterns in HV1 or HV2. The assay described here yields valuable information in terms of the verification of urine sample sources employing only trace amounts of recovered DNA. However, blood cannot be used as a reference sample.

  12. Stability studies of amphetamine and ephedrine derivatives in urine.

    PubMed

    Jiménez, C; de la Torre, R; Ventura, M; Segura, J; Ventura, R

    2006-10-20

    Knowledge of the stability of drugs in biological specimens is a critical consideration for the interpretation of analytical results. Identification of proper storage conditions has been a matter of concern for most toxicology laboratories (both clinical and forensic), and the stability of drugs of abuse has been extensively studied. This concern should be extended to other areas of analytical chemistry like antidoping control. In this work, the stability of ephedrine derivatives (ephedrine, norephedrine, methylephedrine, pseudoephedrine, and norpseudoephedrine), and amphetamine derivatives (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), and 3,4-methylenedioxymethamphetamine (MDMA)) in urine has been studied. Spiked urine samples were prepared for stability testing. Urine samples were quantified by GC/NPD or GC/MS. The homogeneity of each batch of sample was verified before starting the stability study. The stability of analytes was evaluated in sterilized and non-sterilized urine samples at different storage conditions. For long-term stability testing, analyte concentration in urine stored at 4 degrees C and -20 degrees C was determined at different time intervals for 24 months for sterile urine samples, and for 6 months for non-sterile samples. For short-term stability testing, analyte concentration was evaluated in liquid urine stored at 37 degrees C for 7 days. The effect of repeated freezing (at -20 degrees C) and thawing (at room temperature) was also studied in sterile urine for up to three cycles. No significant loss of the analytes under study was observed at any of the investigated conditions. These results show the feasibility of preparing reference materials containing ephedrine and amphetamine derivatives to be used for quality control purposes.

  13. Albumin adsorption onto surfaces of urine collection and analysis containers☆

    PubMed Central

    Robinson, Mary K.; Caudill, Samuel P.; Koch, David D.; Ritchie, James; Hortin, Glen; Eckfeldt, John H.; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W. Greg

    2017-01-01

    Background Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. Methods We added 125I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Results Adsorption of urine albumin (UA) at 5–6 mg/l was <0.9%; and at 90 mg/l was <0.4%. Adsorption was generally less at pH 8 than pH 5 but only 3 cases had p <0.05. Adsorption from 11 unaltered urine samples with albumin 5–333 mg/l was <0.8%. Albumin adsorption for the material with greatest binding was extrapolated to the surface areas of 100 ml and 2 l collection containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2–28%) was larger than that from urine. Conclusions Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. PMID:24513540

  14. Albumin adsorption onto surfaces of urine collection and analysis containers.

    PubMed

    Robinson, Mary K; Caudill, Samuel P; Koch, David D; Ritchie, James; Hortin, Glen; Eckfeldt, John H; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W Greg

    2014-04-20

    Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. We added (125)I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Adsorption of urine albumin (UA) at 5-6 mg/l was <0.9%; and at 90 mg/l was <0.4%. Adsorption was generally less at pH8 than pH5 but only 3 cases had p<0.05. Adsorption from 11 unaltered urine samples with albumin 5-333 mg/l was <0.8%. Albumin adsorption for the material with greatest binding was extrapolated to the surface areas of 100 ml and 2l collection containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2-28%) was larger than that from urine. Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. A Compton scattering technique to determine wood density and locating defects in it

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tondon, Akash, E-mail: akashtondonnsl@gmail.com; Sandhu, B. S.; Singh, Bhajan

    A Compton scattering technique is presented to determine density and void location in the given wooden samples. The technique uses a well collimated gamma ray beam from {sup 137}Cs along with the NaI(Tl) scintillation detector. First, a linear relationship is established between Compton scattered intensity and known density of chemical compounds, and then density of the wood is determined from this linear relation. In another experiment, the ability of penetration of gamma rays is explored to detect voids in wooden (low Z) sample. The sudden reduction in the Compton scattered intensities agrees well with the position and size of voidsmore » in the wooden sample. It is concluded that wood density and the voids of size ∼ 4 mm and more can be detected easily by this method.« less

  16. Urinary concentrations of pyrethroid metabolites in the convenience sample of an urban population of Northern Poland.

    PubMed

    Wielgomas, Bartosz; Nahorski, Wacław; Czarnowski, Wojciech

    2013-06-01

    Urinary concentrations of pyrethroid metabolites were measured in the first void urine samples collected from 132 healthy people living in the Gdańsk region of Northern Poland in 2010 and 2011. Four metabolites of synthetic pyrethroids: cis- and trans-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane-1-carboxylic acids (cis-, trans-Cl2CA), cis-3-(2,2-dibromovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (Br2CA) and 3-phenoxybenzoic acid (3-PBA) were simultaneously liquid-liquid extracted, derivatized with hexafluoroisopropanol and analyzed by a gas chromatography ion-trap mass spectrometry. All the analytes were detected and quantified in the samples with various frequency, 3-phenoxybenzoic being the most often (80%) and the others less frequently (7-11%). Distribution of 3-PBA concentrations followed log-normal model, the mean concentration of 3-phenoxybenzoic acid: 0.393 μg/L (0.327 μg/g creatinine) is similar to those of the other general populations in various regions of the world. Neither sex nor age were predictors of urinary 3-PBA. Our findings suggest wide exposure to pyrethroid insecticides in the Polish general population. There is a continuous need to further study the exposure to synthetic pyrethroids among the general population since there is a strong, increasing trend in their usage. Copyright © 2012 Elsevier GmbH. All rights reserved.

  17. Solid phase extraction of 2,4-D from human urine.

    PubMed

    Thompson, T S; Treble, R G

    1996-10-01

    A method for determining urinary concentrations of 2,4-D in samples collected from non-occupationally, environmentally exposed individuals was developed. The 2,4-D was extracted from fortified human urine samples using octadecylsilane solid phase extraction cartridges. The average percent recovery for urine samples spiked at 2 and 20 ng/mL was 100% and 93%, respectively. The method detection limit was estimated to be 0.75 ng of 2,4-D per mL of urine based on a 10 mL sample size. The potential use of 2,4-dichlorophenylacetic acid as a surrogate standard was also investigated.

  18. Quantitative determination of BAF312, a S1P-R modulator, in human urine by LC-MS/MS: prevention and recovery of lost analyte due to container surface adsorption.

    PubMed

    Li, Wenkui; Luo, Suyi; Smith, Harold T; Tse, Francis L S

    2010-02-15

    Analyte loss due to non-specific binding, especially container surface adsorption, is not uncommon in the quantitative analysis of urine samples. In developing a sensitive LC-MS/MS method for the determination of a drug candidate, BAF312, in human urine, a simple procedure was outlined for identification, confirmation and prevention of analyte non-specific binding to a container surface and to recover the 'non-specific loss' of an analyte, if no transfer has occurred to the original urine samples. Non-specific binding or container surface adsorption can be quickly identified by using freshly spiked urine calibration standards and pre-pooled QC samples during a LC-MS/MS feasibility run. The resulting low recovery of an analyte in urine samples can be prevented through the use of additives, such as the non-ionic surfactant Tween-80, CHAPS and others, to the container prior to urine sample collection. If the urine samples have not been transferred from the bulk container, the 'non-specific binding' of an analyte to the container surface can be reversed by the addition of a specified amount of CHAPS, Tween-80 or bovine serum albumin, followed by appropriate mixing. Among the above agents, Tween-80 is the most cost-effective. beta-cyclodextrin may be suitable in stabilizing the analyte of interest in urine via pre-treating the matrix with the agent. However, post-addition of beta-cyclodextrin to untreated urine samples does not recover the 'lost' analyte due to non-specific binding or container surface adsorption. In the case of BAF312, a dynamic range of 0.0200-20.0 ng/ml in human urine was validated with an overall accuracy and precision for QC sample results ranging from -3.2 to 5.1% (bias) and 3.9 to 10.2% (CV), respectively. Pre- and post-addition of 0.5% (v/v) Tween-80 to the container provided excellent overall analyte recovery and minimal MS signal suppression when a liquid-liquid extraction in combination with an isocratic LC separation was employed. The compound was stable in 0.5% Tween-80 treated human urine QC samples for at least 24 h at room temperature, after three freeze/thaw cycles with storage at < or =-60 degrees C and for at least 3 months when stored at < or =-60 degrees C. The current work could serve as a simple example in trouble shooting non-specific binding or container surface adsorption in quantitative analysis of urine samples. Copyright 2010. Published by Elsevier B.V.

  19. A needle extraction utilizing a molecularly imprinted-sol-gel xerogel for on-line microextraction of the lung cancer biomarker bilirubin from plasma and urine samples.

    PubMed

    Moein, Mohammad Mahdi; Jabbar, Dunia; Colmsjö, Anders; Abdel-Rehim, Mohamed

    2014-10-31

    In the present work, a needle trap utilizing a molecularly imprinted sol-gel xerogel was prepared for the on-line microextraction of bilirubin from plasma and urine samples. Each prepared needle could be used for approximately one hundred extractions before it was discarded. Imprinted and non-imprinted sol-gel xerogel were applied for the extraction of bilirubin from plasma and urine samples. The produced molecularly imprinted sol-gel xerogel polymer showed high binding capacity and fast adsorption/desorption kinetics for bilirubin in plasma and urine samples. The adsorption capacity of molecularly imprinted sol-gel xerogel polymer was approximately 60% higher than that of non-imprinted polymer. The effect of the conditioning, washing and elution solvents, pH, extraction time, adsorption capacity and imprinting factor were investigated. The limit of detection and the lower limit of quantification were set to 1.6 and 5nmolL(-1), respectively using plasma or urine samples. The standard calibration curves were obtained within the concentration range of 5-1000nmolL(-1) in both plasma and urine samples. The coefficients of determination values (R(2)) were ≥0.998 for all runs. The extraction recovery was approximately 80% for BR in the human plasma and urine samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Testing for nandrolone metabolites in urine samples of professional athletes and sedentary subjects by GC/MS/MS analysis.

    PubMed

    Gambelunghe, Cristiana; Sommavilla, Marco; Rossi, Ruggero

    2002-12-01

    The concentrations of nandrolone metabolites, 19-norandrosterone (19-NA) and 19-noretiocholanolone (19-NE) were analysed in urine samples of professional athletes doing intense physical activity and sedentary subjects to verify if there was endogenous production of nandrolone and if there was any link between physical effort and the urinary metabolites of the steroid. We collected 18 urine samples from professional footballers age range 20-30 years, all from the same team, and 18 urine samples from males not doing any physical activity, age range 20-30 years. Neither group used nandrolone. Qualitative and quantitative analyses of urinary nandrolone metabolites were carried out by GC/MS followed by GC/MS/MS to confirm positive samples. This technique has been demonstrated to be an excellent analytical approach for the determination of anabolic steroids at very low detection limits in complex matrices such as urine. In five urine samples from professional footballers traces of 19-NA were detected. No trace of 19-NA was found in the group of sedentary subjects and no trace of 19-NE was found in any urine sample. The absence of nandrolone metabolites in sedentary subjects supports the hypothesis that the presence of 19-NA and 19-NE could be linked to physical effort even though the origin is not yet clear. Copyright 2002 John Wiley & Sons, Ltd.

  1. Performing a urine dipstick test with a clean-catch urine sample is an accurate screening method for urinary tract infections in young infants.

    PubMed

    Herreros, María Luisa; Tagarro, Alfredo; García-Pose, Araceli; Sánchez, Aida; Cañete, Alfonso; Gili, Pablo

    2018-01-01

    This study evaluated using urine dipstick tests with the clean-catch method to screen for urinary tract infection (UTI) in febrile infants under 90 days of age. We carried out a comparative diagnostic accuracy study of infants under 90 days old, who were studied for unexplained fever without any source, in the emergency room of a hospital in Madrid from January 2011 to January 2013. We obtained matched samples of urine using two different methods: a clean-catch, standardised stimulation technique and catheterisation collection. The results of the leucocyte esterase test and nitrite test were compared with their urine cultures. We obtained 60 pairs of matched samples. A combined analysis of leukocyte esterase and, or, nitrites yielded a sensitivity of 86% and a specificity of 80% for the diagnosis of UTIs in clean-catch samples. The sensitivity of leukocyte esterase and, or, nitrites in samples obtained by catheterisation were not statistically different to the clean-catch samples (p = 0.592). Performing urine dipstick tests using urine samples obtained by the clean-catch method was an accurate screening test for diagnosing UTIs in febrile infants of less than 90 days old. This provided a good alternative to bladder catheterisation when screening for UTIs. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  2. 51Cr-EDTA absorption blood test: an easy method for assessing small intestinal permeability in dogs.

    PubMed

    Frias, Rafael; Sankari, Satu; Westermarck, Elias

    2004-01-01

    The 51Cr-EDTA test is a valuable clinical tool for screening intestinal diseases in dogs. The test is performed by calculating the percentage of recovery from urine of a PO-ingested dose of 51Cr-EDTA after 6 or 24 hours. Careful urine collection is a practical limitation of this test in dogs, and our goal was to develop a simpler test that measures 51Cr-EDTA in blood. A 51Cr-EDTA absorption test was simultaneously performed on urine and serum 43 times in healthy Beagle Dogs. Timed blood samples were withdrawn, and urine was collected during a 6-hour period. Percentages of the ingested dose were then calculated in urine and serum. The mean +/- standard deviation (range) percentage in urine after 6 hours was 14.07 +/- 8.72% (3.81-34.18%), whereas results in serum from samples taken at 2, 3, 4, 5, and 6 hours were 0.49 +/- 0.45% (0.02-2.13%), 0.75 +/- 0.52% (0.03-1.89%), 0.82 +/- 0.57% (0.13-2.21%), 0.70 +/- 0.53% (0.12-1.99%), and 0.47 +/- 0.44% (0.11-1.79%), respectively. The results for blood specimens showed good concordance with those for urine, especially for the samples taken at 4 hours (r = 0.89). Moreover, the correlation between urine and blood was better when the sum of the percentages of the recovered analyte from various blood samples was compared with urine. The correlation coefficient when summing 4 blood samples was excellent (r = 0.97) and remained excellent when summing only 2 blood samples taken at 3 and 5 hours (r = 0.95) or at 3 and 4 hours (r = 0.94). We conclude that a serum 51Cr-EDTA test determined by summing successive blood samples provides an easier means of estimating small intestinal permeability in dogs and gives results comparable to those of the 6-hour urine test.

  3. The effect of diet enriched with rapeseed meal on endogenous thiouracil contents in urine and milk of cattle.

    PubMed

    Wozniak, Barbara; Matraszek-Zuchowska, Iwona; Witek, Sebastian; Zmudzki, Jan; Posyniak, Andrzej

    2018-01-15

    Thyreostatic compounds, such as thiouracil, are orally active drugs that can be used to increase the weight of cattle before slaughter. Due to potentially teratogenic and carcinogenic effects of their residues on public health, the use of thyreostats in animal production has been banned in the European Union since 1981. Systematic detection of low concentrations of thiouracil in the urine of livestock in many countries is believed to be of endogenous origin due to the use of Brassicaceae plants in the animal diet. Therefore, the purpose of the study was to determine the effects of diets rich in rapeseed meal on formation of thiouracil in urine and milk of dairy cows. For two weeks three cows were subjected to a diet supplemented with rapeseed at 30%, compared to the control cattle diet which contained up to 11% rapeseed. During the experiment, samples of urine and milk were collected and analysed by LC-MS/MS. The increase and decrease of thiouracil concentration in urine samples in different animals was individual and cyclic. The highest concentration of natural thiouracil determined in urine was 3.61 μg l -1 . It has been found that endogenous thiouracil exists in two tautomeric forms. A few days of storage of frozen urine samples affected the stability of natural thiouracil, whereas an acidic medium improved the stability of the compound and its isomer, which remained stable even after two months of storage at temperatures below -18°C. Due to the instability of thiouracil, urine samples upon sampling should be delivered to the laboratory as soon as possible or properly preserved. In milk samples, thiouracil was not found above the decision limit of the applied method of 0.63 μg l -1 . Preliminary studies have shown that faecal examination for banned thiouracil can be a complementary test for urine samples, and may be helpful in determining the origin of the compound present in urine.

  4. Evaluation of commercial boric acid containing vials for urine culture: low risk of contamination and cost effectiveness considerations.

    PubMed

    Appannanavar, Suma B; Biswal, Manisha; Rajkumari, Nonika; Mohan, Balvinder; Taneja, Neelam

    2013-01-01

    Urine culture is a gold standard in the diagnosis of urinary tract infection. Clean catch midstream urine collection and prompt transportation is essential for appropriate diagnosis. Improper collection and delay in transportation leads to diagnostic dilemma. In developing countries, higher ambient temperatures further complicate the scenario. Here, we have evaluated the role of boric acid as a preservative for urine samples prior to culture in female patients attending outpatient department at our center. Consecutive 104 urine samples were cultured simultaneously in plain uricol (Control-C) and boric acid containing tubes from Becton Dickinson urine culture kit (Boric acid group-BA). In the real-time evaluation, we found that in almost 57% (59/104) of the urine samples tested, it was more effective in maintaining the number of the organisms as compared to samples in the container without any preservative. Our in vitro study of simulated urine cultures revealed that urine samples could be kept up to 12 h before culture in the preservative without any inhibitory effect of boric acid. Though the use of boric acid kit may marginally increase the initial cost but has indirect effects like preventing delays in treatment and avoidance of false prescription of antibiotics. If the man-hours spent on repeat investigations are also taken into consideration, then the economic cost borne by the laboratory would also decrease manifold with the use of these containers.

  5. Screening for urinary tract infection with the Sysmex UF-1000i urine flow cytometer.

    PubMed

    Broeren, Maarten A C; Bahçeci, Semiha; Vader, Huib L; Arents, Niek L A

    2011-03-01

    The diagnosis of urinary tract infection (UTI) by urine culture is time-consuming and can produce up to 60 to 80% negative results. Fast screening methods that can reduce the necessity for urine cultures will have a large impact on overall turnaround time and laboratory economics. We have evaluated the detection of bacteria and leukocytes by a new urine analyzer, the UF-1000i, to identify negative urine samples that can be excluded from urine culture. In total, 1,577 urine samples were analyzed and compared to urine culture. Urine culture showed growth of ≥10(3) CFU/ml in 939 samples (60%). Receiver operating characteristics (ROC) curves and ROC decision plots were been prepared at three different gold standard definitions of a negative urine culture: no growth, growth of bacteria at <10(4) CFU/ml, and growth of bacteria at <10(5) CFU/ml. Also, the reduction in urine cultures and the percentage of false negatives were calculated. At the most stringent gold standard definition of no growth, a chosen sensitivity of 95% resulted in a cutoff value of 26 bacteria/μl, a specificity of 43% and a reduction in urine cultures of only 20%, of which 14% were false negatives. However, at a gold standard definition of <10(5) CFU/ml and a sensitivity of 95%, the UF-1000i cutoff value was 230 bacteria/μl, the specificity was 80%, and the reduction in urine cultures was 52%, of which 0.3% were false negatives. The applicability of the UF-1000i to screen for negative urine samples strongly depends on population characteristics and the definition of a negative urine culture. In our setting, however, the low workload savings and the high percentage of false-negative results do not warrant the UF-1000i to be used as a screening analyzer.

  6. Methamphetamine and Amphetamine Isomer Concentrations in Human Urine Following Controlled Vicks VapoInhaler Administration

    PubMed Central

    Smith, Michael L.; Nichols, Daniel C.; Underwood, Paula; Fuller, Zachary; Moser, Matthew A.; Flegel, Ron; Gorelick, David A.; Newmeyer, Matthew N.; Concheiro, Marta; Huestis, Marilyn A.

    2014-01-01

    Legitimate use of legal intranasal decongestants containing l-methamphetamine may complicate interpretation of urine drug tests positive for amphetamines. Our study hypotheses were that commonly used immunoassays would produce no false-positive results and a recently developed enantiomer-specific gas chromatography–mass spectrometry (GC–MS) procedure would find no d-amphetamine or d-methamphetamine in urine following controlled Vicks VapoInhaler administration at manufacturer's recommended doses. To evaluate these hypotheses, 22 healthy adults were each administered one dose (two inhalations in each nostril) of a Vicks VapoInhaler every 2 h for 10 h on Day 1 (six doses), followed by a single dose on Day 2. Every urine specimen was collected as an individual void for 32 h after the first dose and assayed for d- and l-amphetamines specific isomers with a GC–MS method with >99% purity of R-(−)-α-methoxy-α-(trifluoromethyl)phenylacetyl derivatives and 10 µg/L lower limits of quantification. No d-methamphetamine or d-amphetamine was detected in any urine specimen by GC–MS. The median l-methamphetamine maximum concentration was 62.8 µg/L (range: 11.0–1,440). Only two subjects had detectable l-amphetamine, with maximum concentrations coinciding with l-methamphetamine peak levels, and always ≤4% of the parent's maximum. Three commercial immunoassays for amphetamines EMIT® II Plus, KIMS® II and DRI® had sensitivities, specificities and efficiencies of 100, 97.8, 97.8; 100, 99.6, 99.6 and 100, 100, 100%, respectively. The immunoassays had high efficiencies, but our first hypothesis was not affirmed. The EMIT® II Plus assay produced 2.2% false-positive results, requiring an enantiomer-specific confirmation. PMID:25217541

  7. ARISTOLOCHIC ACID I METABOLISM IN THE ISOLATED PERFUSED RAT KIDNEY

    PubMed Central

    Priestap, Horacio A.; Torres, M. Cecilia; Rieger, Robert A.; Dickman, Kathleen G.; Freshwater, Tomoko; Taft, David R.; Barbieri, Manuel A.; Iden, Charles R.

    2012-01-01

    Aristolochic acids are natural nitro-compounds found globally in the plant genus Aristolochia that have been implicated in the severe illness in humans termed aristolochic acid nephropathy (AAN). Aristolochic acids undergo nitroreduction, among other metabolic reactions, and active intermediates arise that are carcinogenic. Previous experiments with rats showed that aristolochic acid I (AA-I), after oral administration or injection, is subjected to detoxication reactions to give aristolochic acid Ia, aristolactam Ia, aristolactam I and their glucuronide and sulfate conjugates that can be found in urine and faeces. Results obtained with whole rats do not clearly define the role of liver and kidney in such metabolic transformation. In this study, in order to determine the specific role of the kidney on the renal disposition of AA-I and to study the biotransformations suffered by AA-I in this organ, isolated kidneys of rats were perfused with AA-I. AA-I and metabolite concentrations were determined in perfusates and urines using HPLC procedures. The isolated perfused rat kidney model showed that AA-I distributes rapidly and extensively in kidney tissues by uptake from the peritubular capillaries and the tubules. It was also established that the kidney is able to metabolize AA-I into aristolochic acid Ia, aristolochic acid Ia O-sulfate, aristolactam Ia, aristolactam I and aristolactam Ia O-glucuronide. Rapid demethylation and sulfation of AA-I in the kidney generate aristolochic acid Ia and its sulfate conjugate that are voided to the urine. Reduction reactions to give the aristolactam metabolites occur to a slower rate. Renal clearances showed that filtered AA-I is reabsorbed at the tubules whereas the metabolites are secreted. The unconjugated metabolites produced in the renal tissues are transported to both urine and perfusate whereas the conjugated metabolites are almost exclusively secreted to the urine. PMID:22118289

  8. Patterns of care received by Medicaid recipients with urinary tract infections.

    PubMed

    Fargason, C A; Bronstein, J M; Johnson, V A

    1995-10-01

    Urinary tract infections (UTIs) occur commonly in children and may lead to substantial morbidity. Most experts recommend urine cultures for diagnosing UTIs in children. In addition, most experts recommend imaging studies in a portion of children diagnosed with UTIs. The purpose of this study was to assess how rates of performance of urine cultures and imaging studies for children in the Alabama Medicaid program diagnosed with a UTI vary by patient demographics, provider characteristics, and service locations. The study design was a retrospective review of Alabama Medicaid claims data. Children were included as UTI cases if they had a Medicaid claim for urinary tract infections during 1991, were continuously enrolled in Medicaid for that year, and were younger than 8 years of age. Claims were grouped into episodes of care, and episodes were assigned to a diagnosing physician. Physician locations were classified as rural, suburban, or urban using demographic data. Specific laboratory and imaging procedures were identified using CPT codes (Physician's Current Procedural Technology Codes, 4th Edition). We identified 404 episodes of UTI occurring in 380 children. Only 47% of episodes were associated with claims for urine cultures. Claims for urine cultures were more frequently filed by pediatricians in urban locations. In the subset of 114 patients with multiple UTI episodes, only 68% had imaging studies specific for the urinary tract. Only 44% received both a voiding cystourethrogram and renal ultrasound. Claims data suggest that physicians underuse urine cultures in diagnosing UTIs in Alabama pediatric Medicaid recipients. Urban-based pediatricians perform better than other types of physicians. Imaging studies are also used less frequently than is commonly recommended.

  9. MSA Bladder Reference Set Application: Charles Rosser-Hawaii (2014) — EDRN Public Portal

    Cancer.gov

    The goal of this proposal is straightforward. We wish to assay in a discovery set, reference set from EDRN, both PAI-1 and ANG promoters and genes for mutations. Then the results will be confirmed in a test cohort comprised of DNA extracted from fresh frozen tissue (n = 80 BCa patients). DNA from matching buffy coat from these 80 patients will serve as control. Extracted RNA can be assessed for difference in transcription. Furthermore, matched voided urine samples from these 80 patients are available to assess protein levels of PAI-1 and ANG by ELISA in addition to assessing activity of PAI-1 and ANG. At the end, we will link any genetic alteration with changes in RNA, protein and protein activity level as well as clinical features (e.g., age, race, tobacco history, grade, stage and outcomes). This comprehensive study will allow us with certainty to state if there are mutations in the promoters and genes of PAI-1 and ANG that are functional and thus may lead to the growth advantage that we previously demonstrated in our experiments.

  10. The effects of the distribution pattern of multiple voids within LDPE on partial discharge characteristics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shin, D.S.; Han, M.K.; Lee, J.H.

    1996-12-31

    In this paper, the authors have investigated effects of the arrangement of the voids in LDPE samples on PD characteristics, such as phase-related magnitude of PD, number of discharges. The differences of the PD patterns may be attributed to the arrangements of the voids. They have also employed available statistical operators, such as discharge factor and cross correlation factor in order to analyze the PD characteristics. The authors could conclude that partial discharge characteristics show quite different patterns due to the arrangements of voids in spite of the same size. The experimental results suggest that it is important to knowmore » the arrangements of the multiple voids as well as to obtain the information about the number of defects in the insulators.« less

  11. Diary Data Subjected to Cluster Analysis of Intake/Output/Void Habits with Resulting Clusters Compared by Continence Status, Age, Race

    PubMed Central

    Miller, Janis M; Guo, Ying; Rodseth, Sarah Becker

    2011-01-01

    Background Data that incorporate the full complexity of healthy beverage intake and voiding frequency do not exist; therefore, clinicians reviewing bladder habits or voiding diaries for continence care must rely on expert opinion recommendations. Objective To use data-driven cluster analyses to reduce complex voiding diary variables into discrete patterns or data cluster profiles, descriptively name the clusters, and perform validity testing. Method Participants were 352 community women who filled out a 3-day voiding diary. Six variables (void frequency during daytime hours, void frequency during nighttime hours, modal output, total output, total intake, and body mass index) were entered into cluster analyses. The clusters were analyzed for differences by continence status, age, race (Black women, n = 196 White women, n = 156), and for those who were incontinent, by leakage episode severity. Results Three clusters emerged, labeled descriptively as Conventional, Benchmark, and Superplus. The Conventional cluster (68% of the sample) demonstrated mean daily intake of 45 ±13 ounces; mean daily output of 37 ± 15 ounces, mean daily voids 5 ± 2 times, mean modal daytime output 10±0.5 ounces, and mean nighttime voids 1±1 times. The Superplus cluster (7% of the sample) showed double or triple these values across the 5 variables, and the Benchmark cluster (25%) showed values consistent with current popular recommendations on intake and output (e.g., meeting or exceeding the 8 × 8 fluid intake rule of thumb). The clusters differed significantly (p < .05) by age, race, amount of irritating beverages consumed, and incontinence status. Discussion Identification of three discrete clusters provides for a potential parsimonious but data-driven means of classifying individuals for additional epidemiological or clinical study. The clinical utility rests with potential for intervening to move an individual from a high risk to low risk cluster with regards to incontinence. PMID:21317828

  12. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure for young children wearing diapers, a method for collecting urine samples for analysis of pesticide metabolites is needed. To find a practical method, two possibilities were investigated: (1) analysis of expressed urine from cotton diaper inserts ...

  13. Development and evaluation of an enzyme-linked immunosorbent assay (ELISA) method for the measurement of 2,4-dichlorophenoxyacetic acid in human urine.

    PubMed

    Chuang, Jane C; Emon, Jeanette M Van; Durnford, Joyce; Thomas, Kent

    2005-09-15

    An enzyme-linked immunosorbent assay (ELISA) method was developed to quantitatively measure 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine. Samples were diluted (1:5) with phosphate-buffered saline containing 0.05% Tween and 0.02% sodium azide, with analysis by a 96-microwell plate immunoassay format. No clean up was required as dilution step minimized sample interferences. Fifty urine samples were received without identifiers from a subset of pesticide applicators and their spouses in an EPA pesticide exposure study (PES) and analyzed by the ELISA method and a conventional gas chromatography/mass spectrometry (GC/MS) procedure. For the GC/MS analysis, urine samples were extracted with acidic dichloromethane (DCM); methylated by diazomethane and fractionated by a Florisil solid phase extraction (SPE) column prior to GC/MS detection. The percent relative standard deviation (%R.S.D.) of the 96-microwell plate triplicate assays ranged from 1.2 to 22% for the urine samples. Day-to-day variation of the assay results was within +/-20%. Quantitative recoveries (>70%) of 2,4-D were obtained for the spiked urine samples by the ELISA method. Quantitative recoveries (>80%) of 2,4-D were also obtained for these samples by the GC/MS procedure. The overall method precision of these samples was within +/-20% for both the ELISA and GC/MS methods. The estimated quantification limit for 2,4-D in urine was 30ng/mL by ELISA and 0.2ng/mL by GC/MS. A higher quantification limit for the ELISA method is partly due to the requirement of a 1:5 dilution to remove the urine sample matrix effect. The GC/MS method can accommodate a 10:1 concentration factor (10mL of urine converted into 1mL organic solvent for analysis) but requires extraction, methylation and clean up on a solid phase column. The immunoassay and GC/MS data were highly correlated, with a correlation coefficient of 0.94 and a slope of 1.00. Favorable results between the two methods were achieved despite the vast differences in sample preparation. Results indicated that the ELISA method could be used as a high throughput, quantitative monitoring tool for human urine samples to identify individuals with exposure to 2,4-D above the typical background levels.

  14. Quantitative determination of metformin, glyburide and its metabolites in plasma and urine of pregnant patients by LC-MS/MS.

    PubMed

    Zhang, Xing; Wang, Xiaoming; Vernikovskaya, Daria I; Fokina, Valentina M; Nanovskaya, Tatiana N; Hankins, Gary D V; Ahmed, Mahmoud S

    2015-04-01

    This report describes the development and validation of an LC-MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3 and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples was 87-99%, and that from urine samples was 85-95%. The differences in retention times among the analytes and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100-0.113 ng/mL; and MET, 4.95 ng/mL. The LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984-1.02 ng/mL for its five metabolites and 30.0 µg/mL for MET. The relative deviation of this method was <14% for intra-day and inter-day assays in plasma and urine samples, and the accuracy was 86-114% in plasma, and 94-105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. Copyright © 2014 John Wiley & Sons, Ltd.

  15. Quantitative determination of metformin, glyburide and its metabolites in plasma and urine of pregnant patients by LC-MS/MS

    PubMed Central

    Zhang, Xing; Wang, Xiaoming; Vernikovskaya, Daria I.; Fokina, Valentina M.; Nanovskaya, Tatiana N.; Hankins, Gary D.V.; Ahmed, Mahmoud S.

    2014-01-01

    This report describes the development and validation of an LC-MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3, and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples ranged between 87% and 99%, and 85%–95% for urine samples. The differences in retention times among the analytes, and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100–0.113 ng/mL and 4.95 ng/mL for MET. LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984–1.02 ng/mL for its five metabolites and 30.0 μg/mL for MET. The relative deviation of this method was < 14% for intra-day and inter-day assays in plasma and urine samples, and the accuracy ranged between 86% and 114% in plasma, and 94% to 105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. PMID:25164921

  16. A novel way to monitor urine concentration: fluorescent concentration matrices.

    PubMed

    Dubayova, Katarina; Luckova, Iveta; Sabo, Jan; Karabinos, Anton

    2015-01-01

    The amount of water found in urine is important diagnostic information; nevertheless it is not yet directly determined. Indirectly, the water content in urine is expressed by its density (specific gravity). However, without the diuresis value it is not possible to determine whether the increase in density of urine is due to a decrease in water secretion or an increase in the concentration of secreted substances. This problem can be solved by the use of fluorescent concentration 3D-matrices which characterise urine concentration through the pφ (or -logφ) value of the first fluorescence centre. The urine fluorescent concentration 3D-matrix was created by the alignment of the synchronous spectra of the dilution series of urine starting from undiluted (pφ = 0) to 1000-fold diluted urine (pφ = 3). Using the fluorescence concentration 3D-matrix analysis of the urine samples from healthy individuals, a reference range was established for the value pφ, determining the normal, concentrated or diluted type of urine. The diagnostic potential of this approach was tested on urine samples from two patients with a chronic glomerulonephritis. The pφ value of the urine fluorescence concentration 3D-matrix analysis determines whether the urine sample falls within the normal, concentrated or diluted type of urine. This parameter can be directly utilised in sportsmen's hydration state monitoring, as well as in the diagnosis and treatment of serious diseases. An important advantage of this novel diagnostic approach is that a 12/24 h urine collection is not required, which predetermines it for use especially within paediatrics.

  17. Micro-CT and nano-CT analysis of filling quality of three different endodontic sealers.

    PubMed

    Huang, Yan; Celikten, Berkan; de Faria Vasconcelos, Karla; Ferreira Pinheiro Nicolielo, Laura; Lippiatt, Nicholas; Buyuksungur, Arda; Jacobs, Reinhilde; Orhan, Kaan

    2017-12-01

    To investigate voids in different root canal sealers using micro-CT and nano-CT, and to explore the feasibility of using nano-CT for quantitative analysis of sealer filling quality. 30 extracted mandibular central incisors were randomly assigned into three groups according to the applied root canal sealers (Total BC Sealer, Sure Seal Root, AH Plus) by the single cone technique. Subsequently, micro-CT and nano-CT were performed to analyse the incidence rate of voids, void fraction, void volume and their distribution in each sample. Micro-CT evaluation showed no significant difference among sealers for the incidence rate of voids or void fraction in the whole filling materials (p > 0.05), whereas a significant difference was found between AH Plus and the other two sealers using nano-CT (p < 0.05). All three sealers presented less void volume in the apical third; however, higher void volumes were observed in the apical and coronal thirds in AH Plus using micro-CT (p < 0.05), while nano-CT results displayed higher void volume in AH Plus among all the sealers and regions (p < 0.05). Bioactive sealers showed higher root filling rate, lower incidence rate of voids, void fraction and void volume than AH Plus under nano-CT analysis, when round root canals were treated by the single cone technique. The disparate results suggest that the higher resolution of nano-CT have a greater ability of distinguishing internal porosity, and therefore suggesting the potential use of nano-CT in quantitative analysis of filling quality of sealers.

  18. Urinary Concentrations of Insecticide and Herbicide Metabolites among Pregnant Women in Rural Ghana: A Pilot Study.

    PubMed

    Wylie, Blair J; Ae-Ngibise, Kenneth A; Boamah, Ellen A; Mujtaba, Mohammed; Messerlian, Carmen; Hauser, Russ; Coull, Brent; Calafat, Antonia M; Jack, Darby; Kinney, Patrick L; Whyatt, Robin; Owusu-Agyei, Seth; Asante, Kwaku P

    2017-03-29

    Use of pesticides by households in rural Ghana is common for residential pest control, agricultural use, and for the reduction of vectors carrying disease. However, few data are available about exposure to pesticides among this population. Our objective was to quantify urinary concentrations of metabolites of organophosphate (OP), pyrethroid, and select herbicides during pregnancy, and to explore exposure determinants. In 2014, 17 pregnant women from rural Ghana were surveyed about household pesticide use and provided weekly first morning urine voids during three visits ( n = 51 samples). A total of 90.1% (46/51) of samples had detectable OP metabolites [geometric mean, GM (95% CI): 3,5,6-trichloro-2-pyridinol 0.54 µg/L (0.36-0.81), para-nitrophenol 0.71 µg/L (0.51-1.00)], 75.5% (37/49) had detectable pyrethroid metabolites [GM: 3-phenoxybenzoic acid 0.23 µg/L (0.17, 0.32)], and 70.5% (36/51) had detectable 2,4-dichlorophenoxyacetic acid levels, a herbicide [GM: 0.46 µg/L (0.29-0.73)]. Concentrations of para-nitrophenol and 2,4-dichlorophenoxyacetic acid in Ghanaian pregnant women appear higher when compared to nonpregnant reproductive-aged women in a reference U.S. Larger studies are necessary to more fully explore predictors of exposure in this population.

  19. Exposure to phthalates in house dust and associated allergies in children aged 6-12years.

    PubMed

    Ait Bamai, Yu; Araki, Atsuko; Kawai, Toshio; Tsuboi, Tazuru; Saito, Ikue; Yoshioka, Eiji; Cong, Shi; Kishi, Reiko

    2016-11-01

    Phthalates are widely used as plasticizers in household products. Several studies have reported an association between phthalate exposure and an increased risk of allergies. The present study estimated phthalate exposure in children aged 6-12years and assessed potential correlations with allergies. House dust samples were collected from floors and multi-surface objects >35cm above the floor. Urine samples were collected from the first morning void of the day. Daily phthalate intake (DI dust and DI) was estimated using both house dust and urinary metabolite concentrations. Exposure to di-2-ethylhexyl phthalate (DEHP) in floor dust was associated with parental-reported rhino-conjunctivitis. After stratification by gender, this trend was found to only occur in boys. Furthermore, urinary mono-isobutyl phthalate was inversely associated with parental-reported wheeze in boys. DI dust of benzyl butyl phthalate (BBzP) and DEHP were significantly correlated with DI_BBzP and DI_DEHP, respectively. These correlations were stronger with floor than with multi-surface dust. Our results suggest that, among Japanese children, house dust from low surfaces, such as living room floors, might play a meaningful role in the indoor environmental exposure pathway for BBzP and DEHP. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Improved sensitivity of the urine CAA lateral-flow assay for diagnosing active Schistosoma infections by using larger sample volumes.

    PubMed

    Corstjens, Paul L A M; Nyakundi, Ruth K; de Dood, Claudia J; Kariuki, Thomas M; Ochola, Elizabeth A; Karanja, Diana M S; Mwinzi, Pauline N M; van Dam, Govert J

    2015-04-22

    Accurate determination of Schistosoma infection rates in low endemic regions to examine progress towards interruption of transmission and elimination requires highly sensitive diagnostic tools. An existing lateral flow (LF) based test demonstrating ongoing infections through detection of worm circulating anodic antigen (CAA), was improved for sensitivity through implementation of a protocol allowing increased sample input. Urine is the preferred sample as collection is non-invasive and sample volume is generally not a restriction. Centrifugal filtration devices provided a method to concentrate supernatant of urine samples extracted with trichloroacetic acid (TCA). For field trials a practical sample volume of 2 mL urine allowed detection of CAA down to 0.3 pg/mL. The method was evaluated on a set of urine samples (n = 113) from an S. mansoni endemic region (Kisumu, Kenya) and compared to stool microscopy (Kato Katz, KK). In this analysis true positivity was defined as a sample with either a positive KK or UCAA test. Implementation of the concentration method increased clinical sensitivity (Sn) from 44 to 98% when moving from the standard 10 μL (UCAA10 assay) to 2000 μL (UCAA2000 assay) urine sample input. Sn for KK varied between 23 and 35% for a duplicate KK (single stool, two slides) to 52% for a six-fold KK (three consecutive day stools, two slides). The UCAA2000 assay indicated 47 positive samples with CAA concentration above 0.3 pg/mL. The six-fold KK detected 25 egg positives; 1 sample with 2 eggs detected in the 6-fold KK was not identified with the UCAA2000 assay. Larger sample input increased Sn of the UCAA assay to a level indicating 'true' infection. Only a single 2 mL urine sample is needed, but analysing larger sample volumes could still increase test accuracy. The UCAA2000 test is an appropriate candidate for accurate identification of all infected individuals in low-endemic regions. Assay materials do not require refrigeration and collected urine samples may be stored and transported to central test laboratories without the need to be frozen.

  1. The Rapid-Heat LAMPellet Method: A Potential Diagnostic Method for Human Urogenital Schistosomiasis

    PubMed Central

    Carranza-Rodríguez, Cristina; Pérez-Arellano, José Luis; Vicente, Belén; López-Abán, Julio; Muro, Antonio

    2015-01-01

    Background Urogenital schistosomiasis due to Schistosoma haematobium is a serious underestimated public health problem affecting 112 million people - particularly in sub-Saharan Africa. Microscopic examination of urine samples to detect parasite eggs still remains as definitive diagnosis. This work was focussed on developing a novel loop-mediated isothermal amplification (LAMP) assay for detection of S. haematobium DNA in human urine samples as a high-throughput, simple, accurate and affordable diagnostic tool to use in diagnosis of urogenital schistosomiasis. Methodology/Principal Findings A LAMP assay targeting a species specific sequence of S. haematobium ribosomal intergenic spacer was designed. The effectiveness of our LAMP was assessed in a number of patients´ urine samples with microscopy confirmed S. haematobium infection. For potentially large-scale application in field conditions, different DNA extraction methods, including a commercial kit, a modified NaOH extraction method and a rapid heating method were tested using small volumes of urine fractions (whole urine, supernatants and pellets). The heating of pellets from clinical samples was the most efficient method to obtain good-quality DNA detectable by LAMP. The detection limit of our LAMP was 1 fg/µL of S. haematobium DNA in urine samples. When testing all patients´ urine samples included in our study, diagnostic parameters for sensitivity and specificity were calculated for LAMP assay, 100% sensitivity (95% CI: 81.32%-100%) and 86.67% specificity (95% CI: 75.40%-94.05%), and also for microscopy detection of eggs in urine samples, 69.23% sensitivity (95% CI: 48.21% -85.63%) and 100% specificity (95% CI: 93.08%-100%). Conclusions/Significance We have developed and evaluated, for the first time, a LAMP assay for detection of S. haematobium DNA in heated pellets from patients´ urine samples using no complicated requirement procedure for DNA extraction. The procedure has been named the Rapid-Heat LAMPellet method and has the potential to be developed further as a field diagnostic tool for use in urogenital schistosomiasis-endemic areas. PMID:26230990

  2. Daily sodium and potassium excretion can be estimated by scheduled spot urine collections.

    PubMed

    Doenyas-Barak, Keren; Beberashvili, Ilia; Bar-Chaim, Adina; Averbukh, Zhan; Vogel, Ofir; Efrati, Shai

    2015-01-01

    The evaluation of sodium and potassium intake is part of the optimal management of hypertension, metabolic syndrome, renal stones, and other conditions. To date, no convenient method for its evaluation exists, as the gold standard method of 24-hour urine collection is cumbersome and often incorrectly performed, and methods that use spot or shorter collections are not accurate enough to replace the gold standard. The aim of this study was to evaluate the correlation and agreement between a new method that uses multiple-scheduled spot urine collection and the gold standard method of 24-hour urine collection. The urine sodium or potassium to creatinine ratios were determined for four scheduled spot urine samples. The mean ratios of the four spot samples and the ratios of each of the single spot samples were corrected for estimated creatinine excretion and compared to the gold standard. A significant linear correlation was demonstrated between the 24-hour urinary solute excretions and estimated excretion evaluated by any of the scheduled spot urine samples. The correlation of the mean of the four spots was better than for any of the single spots. Bland-Altman plots showed that the differences between these measurements were within the limits of agreement. Four scheduled spot urine samples can be used as a convenient method for estimation of 24-hour sodium or potassium excretion. © 2015 S. Karger AG, Basel.

  3. Estimating population salt intake in India using spot urine samples.

    PubMed

    Petersen, Kristina S; Johnson, Claire; Mohan, Sailesh; Rogers, Kris; Shivashankar, Roopa; Thout, Sudhir Raj; Gupta, Priti; He, Feng J; MacGregor, Graham A; Webster, Jacqui; Santos, Joseph Alvin; Krishnan, Anand; Maulik, Pallab K; Reddy, K Srinath; Gupta, Ruby; Prabhakaran, Dorairaj; Neal, Bruce

    2017-11-01

    To compare estimates of mean population salt intake in North and South India derived from spot urine samples versus 24-h urine collections. In a cross-sectional survey, participants were sampled from slum, urban and rural communities in North and in South India. Participants provided 24-h urine collections, and random morning spot urine samples. Salt intake was estimated from the spot urine samples using a series of established estimating equations. Salt intake data from the 24-h urine collections and spot urine equations were weighted to provide estimates of salt intake for Delhi and Haryana, and Andhra Pradesh. A total of 957 individuals provided a complete 24-h urine collection and a spot urine sample. Weighted mean salt intake based on the 24-h urine collection, was 8.59 (95% confidence interval 7.73-9.45) and 9.46 g/day (8.95-9.96) in Delhi and Haryana, and Andhra Pradesh, respectively. Corresponding estimates based on the Tanaka equation [9.04 (8.63-9.45) and 9.79 g/day (9.62-9.96) for Delhi and Haryana, and Andhra Pradesh, respectively], the Mage equation [8.80 (7.67-9.94) and 10.19 g/day (95% CI 9.59-10.79)], the INTERSALT equation [7.99 (7.61-8.37) and 8.64 g/day (8.04-9.23)] and the INTERSALT equation with potassium [8.13 (7.74-8.52) and 8.81 g/day (8.16-9.46)] were all within 1 g/day of the estimate based upon 24-h collections. For the Toft equation, estimates were 1-2 g/day higher [9.94 (9.24-10.64) and 10.69 g/day (9.44-11.93)] and for the Kawasaki equation they were 3-4 g/day higher [12.14 (11.30-12.97) and 13.64 g/day (13.15-14.12)]. In urban and rural areas in North and South India, most spot urine-based equations provided reasonable estimates of mean population salt intake. Equations that did not provide good estimates may have failed because specimen collection was not aligned with the original method.

  4. Conversion to Silodosin in Men on Conventional α1 -Blockers for Symptomatic Benign Prostatic Hyperplasia.

    PubMed

    Tanaka, Masahiko; Niimi, Aya; Tomita, Kyoichi; Homma, Yukio

    2010-04-01

    α1 -blockers have commonly been used as first-line medical therapy for symptomatic benign prostatic hyperplasia (BPH). Recently, a highly selective α1A -adrenoceptor antagonist, silodosin, was developed in Japan. We examined the efficacy and safety of conversion from conventional α1 -blockers to silodosin in men with BPH. Conversion to silodosin was proposed to consecutive patients on conventional α1 -blockers for symptomatic BPH for at least 6 months. The effects of conversion were examined by the International Prostate Symptom Score, quality of life index, overactive bladder symptom score, peak flow rate, residual urine volume, and adverse events at 12 weeks. The efficacy of silodosin was also evaluated by patients' impression. Eighty-one men underwent conversion, for the most part because of dissatisfaction with the efficacy of their current treatment in improving nocturia or weak stream. The International Prostate Symptom Score total score significantly improved from 12.7 ± 5.9 at baseline to 10.6 ± 5.4 at 4 weeks (P < 0.001) and 10.9 ± 5.8 at 12 weeks (P < 0.01). The progress was mostly due to improvement in voiding symptoms, although reduction of storage symptoms was also significant. The quality of life index also significantly decreased with conversion to silodosin. Efficacy as judged by patients' impression was 76% (37/49) at 12 weeks of treatment. None of the overactive bladder symptom score, peak flow rate, and residual urine volume exhibited significant change. No serious adverse events were observed during the study period. Conversion to silodosin may be beneficial in men who are dissatisfied with conventional α1 -blockers for BPH, and be particularly useful in improving voiding symptoms. © 2010 Blackwell Publishing Asia Pty Ltd.

  5. A novel murine model of chronic prostatitis/chronic pelvic pain syndrome (CP/CPPS) induced by immunization with a spermine binding protein (p25) peptide

    PubMed Central

    Altuntas, Cengiz Z.; Veizi, Elias; Izgi, Kenan; Bicer, Fuat; Ozer, Ahmet; Grimberg, Kerry O.; Bakhautdin, Bakytzhan; Sakalar, Cagri; Tasdemir, Cemal; Tuohy, Vincent K.

    2013-01-01

    The pathophysiology of chronic prostatitis/chronic pelvic pain syndrome (CP/CPPS) is poorly understood. Inflammatory and autoimmune mechanisms may play a role. We developed a murine model of experimental autoimmune prostatitis (EAP) that mimics the human phenotype of CP/CPPS. Eight-week-old mice were immunized subcutaneously with prostate-specific peptides in an emulsion of complete Freund's adjuvant. Mice were euthanized 10 days after immunization, and lymph node cells were isolated and assessed for recall proliferation to each peptide. P25 99–118 was the most immunogenic peptide. T-cell and B-cell immunity and serum levels of C-reactive protein and nitrate/nitrite levels were evaluated over a 9-wk period. Morphometric studies of prostate, 24-h micturition frequencies, and urine volume per void were evaluated. Tactile referred hyperalgesia was measured using von Frey filaments to the pelvic region. The unpaired Student's t-test was used to analyze differences between EAP and control groups. Prostates from p25 99–118-immunized mice demonstrated elevated gene expression levels of TNF-α, IL-17A, IFN-γ, and IL-1β, not observed in control mice. Compared with controls, p25 99–118-immunized mice had significantly higher micturition frequency and decreased urine output per void, and they demonstrated elevated pelvic pain response. p25 99–118 immunization of male SWXJ mice induced prostate-specific autoimmunity characterized by prostate-confined inflammation, increased micturition frequency, and pelvic pain. This autoimmune prostatitis model provides a useful tool for exploring the pathophysiology and new treatments. PMID:23344231

  6. Saw palmetto (Serenoa repens) in men with lower urinary tract symptoms: effects on urodynamic parameters and voiding symptoms.

    PubMed

    Gerber, G S; Zagaja, G P; Bales, G T; Chodak, G W; Contreras, B A

    1998-06-01

    To assess the effects of saw palmetto on voiding symptoms and urodynamic parameters in men with lower urinary tract symptoms (LUTS) presumed secondary to benign prostatic hyperplasia (BPH). Fifty men with previously untreated LUTS and a minimum International Prostate Symptom Score (IPSS) of 10 or greater were treated with a commercially available form of saw palmetto (160 mg twice per day) for 6 months. The initial evaluation included measurement of peak urinary flow rate, postvoid residual urine volume, pressure-flow study, and serum prostate-specific antigen (PSA) level. Patients completed an IPSS, serum PSA was determined, and flow rate was measured every 2 months during the course of the study. A urodynamic evaluation was repeated at the completion of the 6-month trial. The mean IPSS (+/-SD) improved from 19.5+/-5.5 to 12.5+/-7.0 (P <0.001) among the 46 men who completed the study. Significant improvement in the symptom score was noted after treatment with saw palmetto for 2 months. An improvement in symptom score of 50% or greater after treatment with saw palmetto for 2, 4, and 6 months was noted in 21% (10 of 48), 30% (14 of 47), and 46% (21 of 46) of patients, respectively. There was no significant change in peak urinary flow rate, postvoid residual urine volume, or detrusor pressure at peak flow among patients completing the study. No significant change in mean serum PSA level was noted. Saw palmetto is a well-tolerated agent that may significantly improve lower urinary tract symptoms in men with BPH. However, we were unable to demonstrate any significant improvement in objective measures of bladder outlet obstruction. Placebo-controlled trials of saw palmetto are needed to evaluate the true effectiveness of this compound.

  7. Simple DNA extraction of urine samples: Effects of storage temperature and storage time.

    PubMed

    Ng, Huey Hian; Ang, Hwee Chen; Hoe, See Ying; Lim, Mae-Lynn; Tai, Hua Eng; Soh, Richard Choon Hock; Syn, Christopher Kiu-Choong

    2018-06-01

    Urine samples are commonly analysed in cases with suspected illicit drug consumption. In events of alleged sample mishandling, urine sample source identification may be necessary. A simple DNA extraction procedure suitable for STR typing of urine samples was established on the Promega Maxwell ® 16 paramagnetic silica bead platform. A small sample volume of 1.7mL was used. Samples were stored at room temperature, 4°C and -20°C for 100days to investigate the influence of storage temperature and time on extracted DNA quantity and success rate of STR typing. Samples stored at room temperature exhibited a faster decline in DNA yield with time and lower typing success rates as compared to those at 4°C and -20°C. This trend can likely be attributed to DNA degradation. In conclusion, this study presents a quick and effective DNA extraction protocol from a small urine volume stored for up to 100days at 4°C and -20°C. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Exploring the concurrent presence of hepatitis A virus genome in serum, stool, saliva, and urine samples of hepatitis A patients.

    PubMed

    Joshi, Madhuri S; Bhalla, Shilpa; Kalrao, Vijay R; Dhongade, Ramchandra K; Chitambar, Shobha D

    2014-04-01

    The use of saliva and urine as an alternative to serum samples for detection of anti-hepatitis A virus (HAV) IgM antibodies has been documented. However, these samples remain underreported or unexplored for shedding of HAV. To address this issue, paired serum, stool, saliva, and urine samples collected from hepatitis A patients were screened by reverse transcription polymerase chain reaction for detection of HAV RNA. HAV RNA was detected in 67.6% (44/65), 52.3% (34/65), 8.7% (5/57), and 12.3% (8/65) of the serum, stool, saliva, and urine samples, respectively. Phylogenetic analysis of nucleotide sequences obtained for partial RNA polymerase region grouped HAV strains from all of the clinical samples of the study in subgenotype IIIA. Low frequency of HAV nucleic acid in saliva and urine samples indicates limited utility of these samples in genomic studies on HAV but suggests its potential for transmission and infection of hepatitis A. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. ATP release from bladder urothelium and serosa in a rat model of partial bladder outlet obstruction.

    PubMed

    Shiina, Kazuhiro; Hayashida, Ken-Ichiro; Ishikawa, Kazuo; Kawatani, Masahito

    2016-01-01

    Overactive bladder is one of the major health problem especially in elderly people. Adenosine triphosphate (ATP) is released from urinary bladder cells and acts as a smooth muscle contraction and sensory signal in micturition but little is known about the role of ATP release in the pathophysiology of overactive bladder. To assess the relationship between ATP and overactive bladder, we used a partial bladder outlet obstruction (pBOO) model in rats. The bladder caused several changes by pBOO: An increase in bladder weight, hypertrophy of sub-urothelium and sub-serosal area, and frequent non-voiding bladder contraction during urine storage. Basal ATP release from urothelium and serosa of pBOO rats was significantly higher than that of normal rats. Distentioninduced ATP release from urothelium of normal and pBOO rats had no significant change. However, distention-induced ATP release from serosa of pBOO rats was higher than that of normal. These findings may identify ATP especially released from serosa as one of causes of non-voiding contractions and overactive bladder symptoms.

  10. Relation Between Bitumen Content and Percentage Air Voids in Semi Dense Bituminous Concrete

    NASA Astrophysics Data System (ADS)

    Panda, R. P.; Das, Sudhanshu Sekhar; Sahoo, P. K.

    2018-02-01

    Hot mix asphalt (HMA) is a heterogeneous mix of aggregate, mineral filler, bitumen, additives and air voids. Researchers have indicated that the durability of the HMA is sensitive on the actual bitumen content and percentage air void. This paper aims at establishing the relationship between the bitumen content and the percentage air voids in Semi Dense Bituminous Concrete (SDBC) using Viscosity Grade-30 (VG-30) bitumen. Total 54 samples have been collected, for formulation and validation of relationship and observed that the percentage air voids increases with decrease in actual bitumen content and vice versa. A minor increase in percentage air voids beyond practice of designed air voids in Marshall Method of design is required for better performance, indicating a need for reducing the codal provision of minimum bitumen content for SDBC as specified in Specification for Road & Bridges (Fourth Revision) published by Indian Road Congress, 2001. The study shows a possibility of reducing designed minimum bitumen content from codal provision for SDBC by 0.2% of weight with VG-30 grade of Bitumen.

  11. Relation Between Bitumen Content and Percentage Air Voids in Semi Dense Bituminous Concrete

    NASA Astrophysics Data System (ADS)

    Panda, R. P.; Das, Sudhanshu Sekhar; Sahoo, P. K.

    2018-06-01

    Hot mix asphalt (HMA) is a heterogeneous mix of aggregate, mineral filler, bitumen, additives and air voids. Researchers have indicated that the durability of the HMA is sensitive on the actual bitumen content and percentage air void. This paper aims at establishing the relationship between the bitumen content and the percentage air voids in Semi Dense Bituminous Concrete (SDBC) using Viscosity Grade-30 (VG-30) bitumen. Total 54 samples have been collected, for formulation and validation of relationship and observed that the percentage air voids increases with decrease in actual bitumen content and vice versa. A minor increase in percentage air voids beyond practice of designed air voids in Marshall Method of design is required for better performance, indicating a need for reducing the codal provision of minimum bitumen content for SDBC as specified in Specification for Road & Bridges (Fourth Revision) published by Indian Road Congress, 2001. The study shows a possibility of reducing designed minimum bitumen content from codal provision for SDBC by 0.2% of weight with VG-30 grade of Bitumen.

  12. Rapid tests and urine sampling techniques for the diagnosis of urinary tract infection (UTI) in children under five years: a systematic review.

    PubMed

    Whiting, Penny; Westwood, Marie; Watt, Ian; Cooper, Julie; Kleijnen, Jos

    2005-04-05

    Urinary tract infection (UTI) is one of the most common sources of infection in children under five. Prompt diagnosis and treatment is important to reduce the risk of renal scarring. Rapid, cost-effective, methods of UTI diagnosis are required as an alternative to culture. We conducted a systematic review to determine the diagnostic accuracy of rapid tests for detecting UTI in children under five years of age. The evidence supports the use of dipstick positive for both leukocyte esterase and nitrite (pooled LR+ = 28.2, 95% CI: 17.3, 46.0) or microscopy positive for both pyuria and bacteriuria (pooled LR+ = 37.0, 95% CI: 11.0, 125.9) to rule in UTI. Similarly dipstick negative for both LE and nitrite (Pooled LR- = 0.20, 95% CI: 0.16, 0.26) or microscopy negative for both pyuria and bacteriuria (Pooled LR- = 0.11, 95% CI: 0.05, 0.23) can be used to rule out UTI. A test for glucose showed promise in potty-trained children. However, all studies were over 30 years old. Further evaluation of this test may be useful. Dipstick negative for both LE and nitrite or microscopic analysis negative for both pyuria and bacteriuria of a clean voided urine, bag, or nappy/pad specimen may reasonably be used to rule out UTI. These patients can then reasonably be excluded from further investigation, without the need for confirmatory culture. Similarly, combinations of positive tests could be used to rule in UTI, and trigger further investigation.

  13. Rapid tests and urine sampling techniques for the diagnosis of urinary tract infection (UTI) in children under five years: a systematic review

    PubMed Central

    Whiting, Penny; Westwood, Marie; Watt, Ian; Cooper, Julie; Kleijnen, Jos

    2005-01-01

    Background Urinary tract infection (UTI) is one of the most common sources of infection in children under five. Prompt diagnosis and treatment is important to reduce the risk of renal scarring. Rapid, cost-effective, methods of UTI diagnosis are required as an alternative to culture. Methods We conducted a systematic review to determine the diagnostic accuracy of rapid tests for detecting UTI in children under five years of age. Results The evidence supports the use of dipstick positive for both leukocyte esterase and nitrite (pooled LR+ = 28.2, 95% CI: 17.3, 46.0) or microscopy positive for both pyuria and bacteriuria (pooled LR+ = 37.0, 95% CI: 11.0, 125.9) to rule in UTI. Similarly dipstick negative for both LE and nitrite (Pooled LR- = 0.20, 95% CI: 0.16, 0.26) or microscopy negative for both pyuria and bacteriuria (Pooled LR- = 0.11, 95% CI: 0.05, 0.23) can be used to rule out UTI. A test for glucose showed promise in potty-trained children. However, all studies were over 30 years old. Further evaluation of this test may be useful. Conclusion Dipstick negative for both LE and nitrite or microscopic analysis negative for both pyuria and bacteriuria of a clean voided urine, bag, or nappy/pad specimen may reasonably be used to rule out UTI. These patients can then reasonably be excluded from further investigation, without the need for confirmatory culture. Similarly, combinations of positive tests could be used to rule in UTI, and trigger further investigation. PMID:15811182

  14. Seasonal perspective of dietary arsenic consumption and urine arsenic in an endemic population.

    PubMed

    Biswas, Anirban; Deb, Debasree; Ghose, Aloke; Santra, Subhas Chandra; Guha Mazumder, Debendra Nath

    2014-07-01

    Exposure to arsenic in arsenic endemic areas is most remarkable environmental health challenges. Although effects of arsenic contamination are well established, reports are unavailable on probable seasonal variation due to changes of food habit depending on winter and summer seasons, especially for endemic regions of Nadia district, West Bengal. Complete 24-h diets, drinking-cooking water, first morning voided urine samples, and diet history were analyzed on 25 volunteers in arsenic endemic Chakdah block of Nadia district, once in summer followed by once in winter from the same participants. Results depicted no seasonal variation of body weight and body mass index. Arsenic concentration of source drinking and cooking water decreased (p = 0.04) from 26 μg L(-1) in summer to 6 μg L(-1) in winter season. We recorded a seasonal decrease of water intake in male (3.8 and 2.5 L day (-1)) and female (2.6 and 1.2 L day(-1)) participants from summer to winter. Arsenic intake through drinking water decreased (p = 0.04) in winter (29 μg day(-1)) than in summer (100 μg day(-1)), and urinary arsenic concentration decreased (p = 0.018) in winter (41 μg L(-1)) than in summer (69 μg L(-1)). Dietary arsenic intake remained unchanged (p = 0.24) over the seasons. Hence, we can infer that human health risk assessment from arsenic needs an insight over temporal scale.

  15. A magnetic bead-based method for concentrating DNA from human urine for downstream detection.

    PubMed

    Bordelon, Hali; Russ, Patricia K; Wright, David W; Haselton, Frederick R

    2013-01-01

    Due to the presence of PCR inhibitors, PCR cannot be used directly on most clinical samples, including human urine, without pre-treatment. A magnetic bead-based strategy is one potential method to collect biomarkers from urine samples and separate the biomarkers from PCR inhibitors. In this report, a 1 mL urine sample was mixed within the bulb of a transfer pipette containing lyophilized nucleic acid-silica adsorption buffer and silica-coated magnetic beads. After mixing, the sample was transferred from the pipette bulb to a small diameter tube, and captured biomarkers were concentrated using magnetic entrainment of beads through pre-arrayed wash solutions separated by small air gaps. Feasibility was tested using synthetic segments of the 140 bp tuberculosis IS6110 DNA sequence spiked into pooled human urine samples. DNA recovery was evaluated by qPCR. Despite the presence of spiked DNA, no DNA was detectable in unextracted urine samples, presumably due to the presence of PCR inhibitors. However, following extraction with the magnetic bead-based method, we found that ∼50% of spiked TB DNA was recovered from human urine containing roughly 5×10(3) to 5×10(8) copies of IS6110 DNA. In addition, the DNA was concentrated approximately ten-fold into water. The final concentration of DNA in the eluate was 5×10(6), 14×10(6), and 8×10(6) copies/µL for 1, 3, and 5 mL urine samples, respectively. Lyophilized and freshly prepared reagents within the transfer pipette produced similar results, suggesting that long-term storage without refrigeration is possible. DNA recovery increased with the length of the spiked DNA segments from 10±0.9% for a 75 bp DNA sequence to 42±4% for a 100 bp segment and 58±9% for a 140 bp segment. The estimated LOD was 77 copies of DNA/µL of urine. The strategy presented here provides a simple means to achieve high nucleic acid recovery from easily obtained urine samples, which does not contain inhibitors of PCR.

  16. A Magnetic Bead-Based Method for Concentrating DNA from Human Urine for Downstream Detection

    PubMed Central

    Bordelon, Hali; Russ, Patricia K.; Wright, David W.; Haselton, Frederick R.

    2013-01-01

    Due to the presence of PCR inhibitors, PCR cannot be used directly on most clinical samples, including human urine, without pre-treatment. A magnetic bead-based strategy is one potential method to collect biomarkers from urine samples and separate the biomarkers from PCR inhibitors. In this report, a 1 mL urine sample was mixed within the bulb of a transfer pipette containing lyophilized nucleic acid-silica adsorption buffer and silica-coated magnetic beads. After mixing, the sample was transferred from the pipette bulb to a small diameter tube, and captured biomarkers were concentrated using magnetic entrainment of beads through pre-arrayed wash solutions separated by small air gaps. Feasibility was tested using synthetic segments of the 140 bp tuberculosis IS6110 DNA sequence spiked into pooled human urine samples. DNA recovery was evaluated by qPCR. Despite the presence of spiked DNA, no DNA was detectable in unextracted urine samples, presumably due to the presence of PCR inhibitors. However, following extraction with the magnetic bead-based method, we found that ∼50% of spiked TB DNA was recovered from human urine containing roughly 5×103 to 5×108 copies of IS6110 DNA. In addition, the DNA was concentrated approximately ten-fold into water. The final concentration of DNA in the eluate was 5×106, 14×106, and 8×106 copies/µL for 1, 3, and 5 mL urine samples, respectively. Lyophilized and freshly prepared reagents within the transfer pipette produced similar results, suggesting that long-term storage without refrigeration is possible. DNA recovery increased with the length of the spiked DNA segments from 10±0.9% for a 75 bp DNA sequence to 42±4% for a 100 bp segment and 58±9% for a 140 bp segment. The estimated LOD was 77 copies of DNA/µL of urine. The strategy presented here provides a simple means to achieve high nucleic acid recovery from easily obtained urine samples, which does not contain inhibitors of PCR. PMID:23861895

  17. Impact of the International Continence Society (ICS) report on the standardisation of terminology in nocturia on the quality of reports on nocturia and nocturnal polyuria: a systematic review.

    PubMed

    Hofmeester, Ilse; Kollen, Boudewijn J; Steffens, Martijn G; Bosch, J L H Ruud; Drake, Marcus J; Weiss, Jeffrey P; Blanker, Marco H

    2015-04-01

    To systematically review and evaluate the impact of the International Continence Society (ICS)-2002 report on standardisation of terminology in nocturia, on publications reporting on nocturia and nocturnal polyuria (NP). In 2002, the ICS defined NP as a Nocturnal Polyuria Index (nocturnal urine volume/total 24-h urine volume) of >0.2-0.33, depending on age. In April 2013 the PubMed and Embase databases were searched for studies (in English, German, French or Dutch) based on original data and adult participants, investigating the relationship between nocturia and NP. A methodological quality assessment was performed, including scores on external validity, internal validity and informativeness. Quality scores of items were compared between studies published before and after the ICS-2002 report. The search yielded 78 publications based on 66 studies. Quality scores of studies were generally high for internal validity (median 5, interquartile range [IQR] 4-6) but low for external validity. After publication of the ICS-2002 report, external validity showed a significant change from 1 (IQR 1-2) to 2 (IQR 1-2.5; P = 0.019). Nocturia remained undefined in 12 studies. In all, 19 different definitions were used for NP, most often being the ICS (or similar) definition: this covered 52% (n = 11) of studies before and 66% (n = 27) after the ICS-2002 report. Clear definitions of both nocturia and NP were identified in 67% and 76% before, and in 88% and 88% of the studies after the ICS-2002 report, respectively. The ICS-2002 report on standardisation of terminology in nocturia appears to have had a beneficial impact on reporting definitions of nocturia and NP, enabling better interpretation of results and comparisons between research projects. Because the external validity of most of the 66 studies is considered a problem, the results of these studies may not be validly extrapolated to other populations. The ICS definition of NP is used most often. However, its discriminative value seems limited due to the estimated difference of 0.6 nocturnal voids between individuals with and without NP. Refinement of current definitions based on robust research is required. Based on pathophysiological reasoning, we argue that it may be more appropriate to define NP based on nocturnal urine production or nocturnal voided volumes, rather than on a diurnal urine production pattern. © 2014 The Authors. BJU International © 2014 BJU International.

  18. Jet Fuel Exposure and Neurological Health in Military Personnel

    DTIC Science & Technology

    2011-07-01

    and dermal samples E Absorbed Dose measure: Exhaled breath, urine , blood F Lifestyle factors (smoking), use of protective equipment (gloves...toluene, ethylbenzene, xylene, and naphthalene. To assess personal absorbed dose levels to JP8 components, exhaled breath and urine samples were...the following primary analytes of interest were measured: benzene, toluene, ethylbenzene, xylene, and naphthalene. Pre- and post- shift urine samples

  19. The examination of urine samples for pathogenic microbes by the luciferase assay for ATP. 1: The effect of the presence of fungi, fungal like bacteria and kidney cells in urine samples

    NASA Technical Reports Server (NTRS)

    Bush, V. N.

    1973-01-01

    A method for accurately determining urinary tract infections in man is introduced. The method is based on adenosine triphosphate (ATP) concentration in urine samples after removing nonbacterial ATP. Adenosine triphosphate concentration is measured from the bioluminescent reaction of luciferase when mixed with ATP. An examination was also made of the effectiveness of rupturing agents on monkey kidney cells Candia albicans, a Rhodotorula species, and a Streptomyces species in determining whether these cells could contribute ATP to the bacterial ATP value of a urine sample.

  20. Development of an immunochromatographic assay for the β-adrenergic agonist feed additive zilpaterol.

    PubMed

    Shelver, Weilin L; Smith, David J

    2018-06-06

    Zilpaterol is a β-adrenergic agonist feed additive approved in the United States to increase weight gain and improve feed efficiency of cattle. A zilpaterol immunochromatographic assay was developed as an economical and user-friendly rapid detection method for zilpaterol and validated using urine and tissue samples derived from animal studies. The assay sensitivity was 1.7-23.2 ng g -1 or mL -1 across a variety of feed and animal matrices and did not cross-react with clenbuterol or ractopamine. No sample pre-treatment of cattle and sheep urine was needed, but horse urine and feed required dilution; skeletal muscle required solvent extraction prior to testing. Of 32 incurred sheep urine samples tested, zilpaterol content was correctly identified in all but 2 samples. Horse urine containing >10 ng mL -1 of incurred zilpaterol residue (n = 48) was correctly identified as zilpaterol positive. The assay correctly identified 0-day withdrawal sheep muscle samples as zilpaterol positive and the control and longer withdrawal day sheep muscle samples as negative. Zilpaterol was demonstrated to be stable in horse urine when stored at -20°C for 7 years.

  1. Quantification of sulfatides in dried blood and urine spots from metachromatic leukodystrophy patients by liquid chromatography/electrospray tandem mass spectrometry.

    PubMed

    Barcenas, Mariana; Suhr, Teryn R; Scott, C Ronald; Turecek, Frantisek; Gelb, Michael H

    2014-06-10

    Treatments are being developed for metachromatic leukodystrophy (MLD), suggesting the need for eventual newborn screening. Previous studies have shown that sulfatide molecular species are increased in the urine of MLD patients compared to samples from non-MLD individuals, but there is no data using dried blood spots (DBS), the most common sample available for newborn screening laboratories. We used ultra-high performance liquid chromatography/tandem mass spectrometry (UHPLC/MS/MS) to quantify sulfatides in DBS and dried urine spots from 14 MLD patients and 50 non-MLD individuals. Several sulfatide molecular species were increased in dried urine samples from all MLD samples compared to non-MLD samples. Sulfatides, especially low molecular species, were increased in DBS from MLD patients, but the sulfatide levels were relatively low. There was good separation in sulfatide levels between MLD and non-MLD samples when dried urine spots were used, but not with DBS, because DBS from non-MLD individuals have measurable levels of sulfatides. Sulfatide accumulation studies in urine, but not in DBS, emerges as the method of choice if newborn screening is to be proposed for MLD. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. USE OF DISPOSABLE DIAPERS TO COLLECT URINE IN EXPOSURE STUDIES

    EPA Science Inventory

    Large studies of children's health as it relates to exposures to chemicals in the environment often require measurements of biomarkers of chemical exposures or effects in urine samples. But collection of urine samples from infants and toddlers is difficult. For large exposure s...

  3. The Use of Chlorhexidine/n-Propyl Gallate (CPG) as an Ambient-Temperature Urine Preservative

    NASA Technical Reports Server (NTRS)

    Nillen, Jeannie L.; Smith, Scott M.

    2003-01-01

    A safe, effective ambient temperature urine preservative, chlorhexidine/n-propyl gallate (CPG), has been formulated for use during spacefli ght that reduces the effects of oxidation and bacterial contamination on sample integrity while maintaining urine pH. The ability of this preservative to maintain stability of nine key analytes was evaluated for a period of one year. CPG effectively maintained stability of a mmonia, total nitrogen, 3-methylhistidine, chloride, sodium, potassiu m, and urea; however, creatinine and osmolality were not preserved by CPG. These data indicate that CPG offers prolonged room-temperature storage for multiple urine analytes, reducing the requirements for f rozen urine storage on future spaceflights. Iii medical applications on Earth, this technology can allow urine samples to be collected in remote settings and eliminate the need to ship frozen samples.

  4. Glucose urine test

    MedlinePlus

    Urine sugar test; Urine glucose test; Glucosuria test; Glycosuria test ... After you provide a urine sample, it is tested right away. The health care provider uses a dipstick made with a color-sensitive pad. The ...

  5. 24-hour urinary aldosterone excretion test

    MedlinePlus

    Aldosterone - urine; Addison disease - urine aldosterone; Cirrhosis - serum aldosterone ... A 24-hour urine sample is needed. You will need to collect your urine over 24 hours . Your health care provider will tell ...

  6. Development of a new protocol for rapid bacterial identification and susceptibility testing directly from urine samples.

    PubMed

    Zboromyrska, Y; Rubio, E; Alejo, I; Vergara, A; Mons, A; Campo, I; Bosch, J; Marco, F; Vila, J

    2016-06-01

    The current gold standard method for the diagnosis of urinary tract infections (UTI) is urine culture that requires 18-48 h for the identification of the causative microorganisms and an additional 24 h until the results of antimicrobial susceptibility testing (AST) are available. The aim of this study was to shorten the time of urine sample processing by a combination of flow cytometry for screening and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for bacterial identification followed by AST directly from urine. The study was divided into two parts. During the first part, 675 urine samples were processed by a flow cytometry device and a cut-off value of bacterial count was determined to select samples for direct identification by MALDI-TOF-MS at ≥5 × 10(6) bacteria/mL. During the second part, 163 of 1029 processed samples reached the cut-off value. The sample preparation protocol for direct identification included two centrifugation and two washing steps. Direct AST was performed by the disc diffusion method if a reliable direct identification was obtained. Direct MALDI-TOF-MS identification was performed in 140 urine samples; 125 of the samples were positive by urine culture, 12 were contaminated and 3 were negative. Reliable direct identification was obtained in 108 (86.4%) of the 125 positive samples. AST was performed in 102 identified samples, and the results were fully concordant with the routine method among 83 monomicrobial infections. In conclusion, the turnaround time of the protocol described to diagnose UTI was about 1 h for microbial identification and 18-24 h for AST. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  7. Lead Quantification in Urine Samples of Athletes by Coupling DLLME with UV-Vis Spectrophotometry.

    PubMed

    Faraji, Hakim; Helalizadeh, Masoumeh

    2017-04-01

    Urine lead level is one of the most employed measures of lead exposure and risk. The urine samples used in this study were obtained from ten healthy male cyclists. Dispersive liquid-liquid microextraction combined with ultraviolet and visible spectrophotometry was utilized for preconcentration, extraction, and determination of lead in urine samples. Optimization of the independent variables was carried out based on chemometric methods in three steps. According to the screening and optimization study, 133 μL of CCl 4 (extracting solvent), 1.34 mL ethanol (dispersing solvent), pH 2.0, 0.00 % of salt, and 0.1 % O,O-diethyl dithiophosphoric (chelating agent) were used as the optimum independent variables for microextraction and determination of lead. Under the optimized conditions, R 2 was 0.9991, and linearity range was 0.01-100 μg L -1 . Precision was evaluated in terms of repeatability and intermediate precision, with relative standard deviations being <9.1 and <15.3 %, respectively. The accuracy was estimated using urine samples of cyclists as real samples and it was confirmed. The relative error of ≤5 % was considered significant in the method specificity study. The lead concentration mean for the cyclists was 3.79 μg L -1 in urine samples. As a result, the proposed method is a robust technique to quantify lead concentrations higher than 11.6 ng L -1 in urine samples.

  8. Rapid Diagnosis of Tuberculosis from Analysis of Urine Volatile Organic Compounds

    PubMed Central

    Lim, Sung H.; Martino, Raymond; Anikst, Victoria; Xu, Zeyu; Mix, Samantha; Benjamin, Robert; Schub, Herbert; Eiden, Michael; Rhodes, Paul A.; Banaei, Niaz

    2017-01-01

    The World Health Organization has called for simple, sensitive, and non-sputum diagnostics for tuberculosis. We report development of a urine tuberculosis test using a colorimetric sensor array (CSA). The sensor comprised of 73 different indicators captures high-dimensional, spatiotemporal signatures of volatile chemicals emitted by human urine samples. The sensor responses to 63 urine samples collected from 22 tuberculosis cases and 41 symptomatic controls were measured under five different urine test conditions. Basified testing condition yielded the best accuracy with 85.5% sensitivity and 79.5% specificity. The CSA urine assay offers desired features needed for tuberculosis diagnosis in endemic settings. PMID:29057329

  9. Can nail, hair and urine be used for biomonitoring of human exposure to perfluorooctane sulfonate and perfluorooctanoic acid?

    PubMed

    Li, Jingguang; Guo, Feifei; Wang, Yuxin; Zhang, Jialing; Zhong, Yuxin; Zhao, Yunfeng; Wu, Yongning

    2013-03-01

    Because of the disadvantages of invasive sampling, it is desirable to explore non-invasive matrices for human biomonitoring of perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA). The aim of this study was to evaluate the application of nail, hair and urine for human biomonitoring of PFOS and PFOA. The concentrations of PFOS and PFOA in matched nail, hair, urine and serum samples collected from 64 donors were measured. The chemicals of interest were detected with high detection frequency in these matrices (90%-100%) except for PFOA in urine samples (56%). Generally, the gender influences on the levels of PFOS and PFOA in these non-invasive matrices were in agreement with that in serum. For PFOS, the coefficients of Spearman correlation between serum samples and nail, hair and urine samples were 0.786 (p<0.001), 0.545 (p<0.001) and 0.302 (p<0.05), respectively. For PFOA, the correlation was only observed between nail samples and serum samples with a correlation coefficient of 0.299 (p<0.05). The results suggested that nail has more potential than hair and urine to be applied in human biomonitoring for PFOS and PFOA in general populations. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Lower urinary tract symptoms that predict microscopic pyuria.

    PubMed

    Khasriya, Rajvinder; Barcella, William; De Iorio, Maria; Swamy, Sheela; Gill, Kiren; Kupelian, Anthony; Malone-Lee, James

    2017-10-02

    Urinary dipsticks and culture analyses of a mid-stream urine specimen (MSU) at 10 5  cfu ml -1 of a known urinary pathogen are considered the gold standard investigations for diagnosing urinary tract infection (UTI). However, the reliability of these tests has been much criticised and they may mislead. It is now widely accepted that pyuria (≥1 WBC μl -1 ) detected by microscopy of a fresh unspun, unstained specimen of urine is the best biological indicator of UTI available. We aimed to scrutinise the greater potential of symptoms analysis in detecting pyuria and UTI. Lower urinary tract symptom (LUTS) descriptions were collected from patients with chronic lower urinary tract symptoms referred to a tertiary referral unit. The symptoms informed a 39-question inventory, grouped into storage, voiding, stress incontinence and pain symptoms. All questions sought a binary yes or no response. A bespoke software package was developed to collect the data. The study was powered to a sample of at least 1,990 patients, with sufficient power to analyse 39 symptoms in a linear model with an effect size of Cohen's f 2  = 0.02, type 1 error probability = 0.05; and power (1-β); 95% where β is the probability of type 2 error). The inventory was administered to 2,050 female patients between August 2004 and November 2011. The data were collated and the following properties assessed: internal consistency, test-retest reliability, inter-observer reliability, internal responsiveness, external responsiveness, construct validity analysis and a comparison with the International Consultation on Incontinence Modular Questionnaire for female lower urinary tract symptoms (ICIQ-FLUTS). The dependent variable used as a surrogate marker of UTI was microscopic pyuria. An MSU sample was sent for routine culture. The symptoms proved reliable predictors of microscopic pyuria. In particular, voiding symptoms correlated well with microscopic pyuria (χ 2  = 88, df = 1, p < 0.001). The symptom inventory has significant psychometric characteristics as below: test-retest reliability: Cronbach's alpha was 0.981; inter-observer reliability, Cronbach's alpha was 0.995, internal responsiveness F = 221, p < 0.001, external responsiveness F = 359, df = 5, p < 0.001. The correlation coefficients for the domains of the ICIQ-FLUTS were around R = 0.5, p < 0.001. This symptoms score performed well on the standard, psychometric validation. The score changed in response to treatment and in a direction appropriate to the changes in microscopic pyuria. It correlated with measures of quality of life. It would seem to make a good candidate for monitoring treatment progress in ordinary clinical practice.

  11. Critical velocities for deflagration and detonation triggered by voids in a REBO high explosive

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herring, Stuart Davis; Germann, Timothy C; Jensen, Niels G

    2010-01-01

    The effects of circular voids on the shock sensitivity of a two-dimensional model high explosive crystal are considered. We simulate a piston impact using molecular dynamics simulations with a Reactive Empirical Bond Order (REBO) model potential for a sub-micron, sub-ns exothermic reaction in a diatomic molecular solid. The probability of initiating chemical reactions is found to rise more suddenly with increasing piston velocity for larger voids that collapse more deterministically. A void with radius as small as 10 nm reduces the minimum initiating velocity by a factor of 4. The transition at larger velocities to detonation is studied in amore » micron-long sample with a single void (and its periodic images). The reaction yield during the shock traversal increases rapidly with velocity, then becomes a prompt, reliable detonation. A void of radius 2.5 nm reduces the critical velocity by 10% from the perfect crystal. A Pop plot of the time-to-detonation at higher velocities shows a characteristic pressure dependence.« less

  12. Void Formation/Elimination and Viscoelastic Response of Polyphenylsilsesquioxane Monolith.

    PubMed

    Daiko, Yusuke; Oda, Yuki; Honda, Sawao; Iwamoto, Yuji

    2018-05-19

    Polyphenylsilsesquioxane (PhSiO 3/2 ) particles as an organic-inorganic hybrid were prepared using sol-gel method, and monolithic samples were obtained via a warm-pressing. The reaction mechanism of particles' polymerization and transformation to the monolith under the warm-press were investigated using solid state 29 Si nuclear magnetic resonance (NMR) spectrometer, thermal gravimetric-differential thermal analyzer (TG-DTA), mass spectrometer (MS) and scanning electron microscope (SEM). Transparent and void-free monoliths are successfully obtained by warm-pressing above 180 °C. Both the terminal ⁻OH groups on particles' surface and warm-pressing are necessary for preparation of void-free PhSiO 3/2 monolith. From the load-displacement measurement at various temperatures, a viscoelastic deformation is seen for PhSiO 3/2 monolith with voids. On the other hand, an elastic deformation is seen for void-free PhSiO 3/2 monolith, and the void-free monolith shows much higher breakdown voltage.

  13. NHEXAS PHASE I MARYLAND STUDY--PESTICIDE METABOLITES IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Pesticide Metabolites in Urine data set contains analytical results for measurements of up to 9 pesticides in 345 urine samples over 79 households. Each sample was collected from the primary respondent within each household during the study and represented the first morning ...

  14. NHEXAS PHASE I ARIZONA STUDY--PESTICIDE METABOLITES IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Pesticide Metabolites in Urine data set contains analytical results for measurements of up to 4 pesticide metabolites in 176 urine samples over 176 households. Each sample was collected from the primary respondent within each household during Stage III of the NHEXAS study. ...

  15. Influence of storage conditions on aluminum concentrations in serum, dialysis fluid, urine, and tap water.

    PubMed

    Wilhelm, M; Ohnesorge, F K

    1990-01-01

    The influence of storage temperature, vessel type, and treatment on alterations of aluminum (Al) concentrations in serum, urine, and dialysis fluid samples was studied at three different concentrations for each sample over an 18-month period. Furthermore, the influence of acidification on Al levels in tap water, urine, and dialysis fluid samples was studied over a four-month period. Al was measured by atomic absorption spectrometry. Sample storage in glass vessels was unsuitable, whereas only minor alterations of Al levels were observed with storage in polypropylene tubes, polystyrene tubes, and Monovettes. By using appropriate plastic containers, acid washing of the vessels showed no improvement. Frozen storage was superior compared with 4 degrees C, whereas storage at -80 degrees C offered no advantage compared with storage at -20 degrees C. Acidification of tap water samples was necessary to stabilize Al levels during storage. No striking effect of acidification on Al levels in urine and dialysis fluid samples was found. It is concluded that longterm storage of serum, urine, tap water, and dialysis fluid samples is possible if appropriate conditions are used.

  16. Detection of novel visible-light region absorbance peaks in the urine after alkalization in patients with alkaptonuria.

    PubMed

    Tokuhara, Yasunori; Shukuya, Kenichi; Tanaka, Masami; Mouri, Mariko; Ohkawa, Ryunosuke; Fujishiro, Midori; Takahashi, Tomoo; Okubo, Shigeo; Yokota, Hiromitsu; Kurano, Makoto; Ikeda, Hitoshi; Yamaguchi, Seiji; Inagaki, Shinobu; Ishige-Wada, Mika; Usui, Hiromi; Yatomi, Yutaka; Shimosawa, Tatsuo

    2014-01-01

    Alkaptonuria, caused by a deficiency of homogentisate 1,2-dioxygenase, results in the accumulation of homogentisic acid (2,5-dihydroxyphenylacetic acid, HGA) in the urine. Alkaptonuria is suspected when the urine changes color after it is left to stand at room temperature for several hours to days; oxidation of homogentisic acid to benzoquinone acetic acid underlies this color change, which is accelerated by the addition of alkali. In an attempt to develop a facile screening test for alkaptonuria, we added alkali to urine samples obtained from patients with alkaptonuria and measured the absorbance spectra in the visible light region. We evaluated the characteristics of the absorption spectra of urine samples obtained from patients with alkaptonuria (n = 2) and compared them with those of urine specimens obtained from healthy volunteers (n = 5) and patients with phenylketonuria (n = 3), and also of synthetic homogentisic acid solution after alkalization. Alkalization of the urine samples and HGA solution was carried out by the addition of NaOH, KOH or NH4OH. The sample solutions were incubated at room temperature for 1 min, followed by measurement of the absorption spectra. Addition of alkali to alkaptonuric urine yielded characteristic absorption peaks at 406 nm and 430 nm; an identical result was obtained from HGA solution after alkalization. The absorbance values at both 406 nm and 430 nm increased in a time-dependent manner. In addition, the absorbance values at these peaks were greater in strongly alkaline samples (NaOH- KOH-added) as compared with those in weakly alkaline samples (NH4OH-added). In addition, the peaks disappeared following the addition of ascorbic acid to the samples. We found two characteristic peaks at 406 nm and 430 nm in both alkaptonuric urine and HGA solution after alkalization. This new quick and easy method may pave the way for the development of an easy method for the diagnosis of alkaptonuria.

  17. Detection of Novel Visible-Light Region Absorbance Peaks in the Urine after Alkalization in Patients with Alkaptonuria

    PubMed Central

    Tokuhara, Yasunori; Shukuya, Kenichi; Tanaka, Masami; Mouri, Mariko; Ohkawa, Ryunosuke; Fujishiro, Midori; Takahashi, Tomoo; Okubo, Shigeo; Yokota, Hiromitsu; Kurano, Makoto; Ikeda, Hitoshi; Yamaguchi, Seiji; Inagaki, Shinobu; Ishige-Wada, Mika; Usui, Hiromi; Yatomi, Yutaka; Shimosawa, Tatsuo

    2014-01-01

    Background Alkaptonuria, caused by a deficiency of homogentisate 1,2-dioxygenase, results in the accumulation of homogentisic acid (2,5-dihydroxyphenylacetic acid, HGA) in the urine. Alkaptonuria is suspected when the urine changes color after it is left to stand at room temperature for several hours to days; oxidation of homogentisic acid to benzoquinone acetic acid underlies this color change, which is accelerated by the addition of alkali. In an attempt to develop a facile screening test for alkaptonuria, we added alkali to urine samples obtained from patients with alkaptonuria and measured the absorbance spectra in the visible light region. Methods We evaluated the characteristics of the absorption spectra of urine samples obtained from patients with alkaptonuria (n = 2) and compared them with those of urine specimens obtained from healthy volunteers (n = 5) and patients with phenylketonuria (n = 3), and also of synthetic homogentisic acid solution after alkalization. Alkalization of the urine samples and HGA solution was carried out by the addition of NaOH, KOH or NH4OH. The sample solutions were incubated at room temperature for 1 min, followed by measurement of the absorption spectra. Results Addition of alkali to alkaptonuric urine yielded characteristic absorption peaks at 406 nm and 430 nm; an identical result was obtained from HGA solution after alkalization. The absorbance values at both 406 nm and 430 nm increased in a time-dependent manner. In addition, the absorbance values at these peaks were greater in strongly alkaline samples (NaOH- KOH-added) as compared with those in weakly alkaline samples (NH4OH-added). In addition, the peaks disappeared following the addition of ascorbic acid to the samples. Conclusions We found two characteristic peaks at 406 nm and 430 nm in both alkaptonuric urine and HGA solution after alkalization. This new quick and easy method may pave the way for the development of an easy method for the diagnosis of alkaptonuria. PMID:24466168

  18. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    NASA Technical Reports Server (NTRS)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  19. Diagnostic utility and cost-effectiveness of reflex bacterial culture for the detection of urinary tract infection in dogs with low urine specific gravity.

    PubMed

    Tivapasi, Musavenga T; Hodges, Joanne; Byrne, Barbara A; Christopher, Mary M

    2009-09-01

    Urinary tract infections (UTIs) may be subclinical or difficult to detect in dilute urine as sediment abnormalities may not be observed. In our laboratory, bacterial culture is automatically performed (reflex culture) on samples with urine specific gravity (USG)< or =1.013 to increase the likelihood of detecting infection. The value of routine culture of dilute urine, however, has not been fully assessed. The purpose of this retrospective study was to evaluate the frequency of positive bacterial cultures and analyze the diagnostic utility and cost-effectiveness of culture compared with routine sediment examination for detecting UTI in dilute urine specimens from dogs. Urinalysis and concurrent aerobic bacterial culture results were obtained from the electronic medical record system at the University of California-Davis Veterinary Medical Teaching Hospital for samples with USG< or =1.013 analyzed from July 1998 through January 2005. Urine collection method, presence of leukocytes and bacteria, bacterial culture results, and clinical diagnosis were recorded. Cost-effectiveness of reflex culture, based on low USG as the sole criterion, was evaluated. Of 1264 urine specimens, 106 (8.4%) had positive bacterial cultures. Using culture as the gold standard, sediment evaluation had a diagnostic sensitivity of 58.5% and specificity of 98.3% (diagnostic accuracy 94.9%). An additional cost of $60 per patient was incurred, leading to average annual costs of $11,668 for reflex bacterial cultures of all samples with low USG, regardless of collection method. Within our study population, 10 urine samples needed to be cultured for each true positive result. The sensitivity of urine sediment evaluation is low for UTI in dilute urine samples; however, reflex bacterial culture does not appear to be cost-effective in dogs with USG< or =1.013 in the absence of active urine sediment or high clinical suspicion for UTI.

  20. Comparison of osmolality and refractometric readings of Hispaniolan Amazon parrot (Amazona ventralis) urine.

    PubMed

    Brock, A Paige; Grunkemeyer, Vanessa L; Fry, Michael M; Hall, James S; Bartges, Joseph W

    2013-12-01

    To evaluate the relationship between osmolality and specific gravity of urine samples from clinically normal adult parrots and to determine a formula to convert urine specific gravity (USG) measured on a reference scale to a more accurate USG value for an avian species, urine samples were collected opportunistically from a colony of Hispaniolan Amazon parrots (Amazona ventralis). Samples were analyzed by using a veterinary refractometer, and specific gravity was measured on both canine and feline scales. Osmolality was measured by vapor pressure osmometry. Specific gravity and osmolality measurements were highly correlated (r = 0.96). The linear relationship between refractivity measurements on a reference scale and osmolality was determined. An equation was calculated to allow specific gravity results from a medical refractometer to be converted to specific gravity values of Hispaniolan Amazon parrots: USGHAp = 0.201 +0.798(USGref). Use of the reference-canine scale to approximate the osmolality of parrot urine leads to an overestimation of the true osmolality of the sample. In addition, this error increases as the concentration of urine increases. Compared with the human-canine scale, the feline scale provides a closer approximation to urine osmolality of Hispaniolan Amazon parrots but still results in overestimation of osmolality.

  1. Pyrazine Analogues Are Active Components of Wolf Urine That Induce Avoidance and Freezing Behaviours in Mice

    PubMed Central

    Osada, Kazumi; Kurihara, Kenzo; Izumi, Hiroshi; Kashiwayanagi, Makoto

    2013-01-01

    Background The common grey wolf (Canis lupus) is found throughout the entire Northern hemisphere and preys on many kinds of mammals. The urine of the wolf contains a number of volatile constituents that can potentially be used for predator–prey chemosignalling. Although wolf urine is put to practical use to keep rabbits, rodents, deer and so on at bay, we are unaware of any prior behavioural studies or chemical analyses regarding the fear-inducing impact of wolf urine on laboratory mice. Methodology/Principal Findings Three wolf urine samples harvested at different times were used in this study. All of them induced stereotypical fear-associated behaviors (i.e., avoidance and freezing) in female mice. The levels of certain urinary volatiles varied widely among the samples. To identify the volatiles that provoked avoidance and freezing, behavioural, chemical, and immunohistochemical analyses were performed. One of the urine samples (sample C) had higher levels of 2,6-dimethylpyrazine (DMP), trimethylpyrazine (TMP), and 3-ethyl-2,5-dimethyl pyrazine (EDMP) compared with the other two urine samples (samples A and B). In addition, sample C induced avoidance and freezing behaviours more effectively than samples A and B. Moreover, only sample C led to pronounced expression of Fos-immunoreactive cells in the accessory olfactory bulb (AOB) of female mice. Freezing behaviour and Fos immunoreactivity were markedly enhanced when the mice were confronted with a mixture of purified DMP, TMP, and EDMP vs. any one pyrazine alone. Conclusions/Significance The current results suggest that wolf urinary volatiles can engender aversive and fear-related responses in mice. Pyrazine analogues were identified as the predominant active components among these volatiles to induce avoidance and freezing behaviours via stimulation of the murine AOB. PMID:23637901

  2. Evidence for false-positive results for boldenone testing of veal urine due to faecal cross-contamination during sampling.

    PubMed

    Sgoifo Rossi, C A; Arioli, F; Bassini, A; Chiesa, L M; Dell'Orto, V; Montana, M; Pompa, G

    2004-08-01

    European Directive 96/22/EC, which controls veterinary residues in animals, does not permit the presence of synthetic growth promoters in products of animal origin or in livestock. Boldenone is categorized in class A3 (growth promoters -- steroids) and is thus a banned substance. Testing of veal urine for banned substances is part of the European Union statutory programme for animals going into the food chain. In relation to this monitoring, three studies were conducted to investigate the apparent presence of the banned growth promoter boldenone in veal urine, which was suspected as being caused by interference from faecal contamination of the sample. In the first study, urine samples were collected at different times (time 0 and after 30 min) using (1) a conventional zoonotechnical apron and (2) a technique designed specifically to avoid faecal contamination ('kettle'). This resulted in samples that were, respectively, positive and negative for the presence of alpha-boldenone (alpha-BOL). In a second study, urine samples negative to alpha-BOL were collected from eight veal calves, but became positive after deliberate faecal contamination. In a third study, data obtained from the Italian RNP (Residual National Program) indicated that 18.1% of 3295 urine samples collected using the zootechnical apron were positive for alpha-BOL and 2.1% for beta-boldenone (beta-BOL), whilst of 902 samples collected using the kettle, beta-BOL was not detected in any samples and only 0.2% were positive to alpha-BOL, in concentrations lower than 2 ng ml(-1). These results further support the supposition that faecal contamination of the urine during sample collection can lead to false-positive results during boldenone analysis.

  3. Contrast-enhanced voiding urosonography: in vitro evaluation of a second-generation ultrasound contrast agent for in vivo optimization.

    PubMed

    Back, Susan J; Edgar, J Christopher; Canning, Douglas A; Darge, Kassa

    2015-09-01

    Pediatric contrast-enhanced ultrasound (CEUS) is primarily performed outside the United States where a track record for safety in intravenous and intravesical applications has been established. Contrast-enhanced voiding urosonography (ceVUS) has also been shown to have a much higher rate of vesicoureteral reflux detection compared to voiding cystourethrography. US contrast agents available in the United States differ from those abroad. Optison® (GE Healthcare, Princeton, NJ) is such an US contrast agent. While Optison® has similar characteristics to other second-generation agents, it has never been used for ceVUS. In vitro optimization of dose and imaging parameters as well as assessment of contrast visualization when delivered in conditions similar to ceVUS are necessary starting points prior to in vivo applications. To optimize the intravesical use of Optison® in vitro for ceVUS before its use in pediatric studies. The experimental design simulated intravesical use. Using 9- and 12-MHz linear transducers, we scanned 20-mL syringes varying mechanical index, US contrast agent concentration (0.25%, 0.5%, 1.0%), solvent (saline, urine, radiographic contrast agent) and time out of refrigeration. We evaluated mechanical index settings and contrast duration, optimized the contrast dose, measured the effect of urine and radiographic contrast agent, and the impact of length of time of contrast outside of the refrigerator on US contrast appearance. We scanned 50-ml saline bags to assess the appearance and duration of US contrast with different delivery systems (injection vs. infusion). Consistent contrast visualization was achieved at a mechanical index of 0.06-0.17 and 0.11-0.48 for the L9 and L12 MHz transducers (P < 0.01), respectively. Thus, it was necessary to increase the mechanical index for better contrast visualization of the microbubbles with a higher transducer frequency. The lowest mechanical index for earliest visible microbubble destruction was 0.21 for the 9 MHz and 0.39 for the 12 MHz (P < 0.01) transducers. The 0.5% US contrast agent volume to bladder filling was the most optimal. At this concentration, the mean time to visualize homogenous contrast was 2 min and destruction of approximately half of the microbubbles in the field of view occurred in 7.8 min using the 9-MHz transducer. During contrast infusion, the contrast dose needed to be reduced to 0.12% for maintenance of optimal visualization of microbubbles. There was no deleterious effect on the visualization of contrast in the presence of urine or radiographic contrast agent. Infusion of the US contrast agent speeded visualization of homogeneous enhancement compared with injection. Time outside refrigeration did not affect contrast performance. Transducer mechanical index settings need to be optimized. A very low dose of the US contrast agent Optison® will suffice for intravesical application, i.e. 0.12% to 0.50% of the bladder filling volume. The presence of urine or radiographic contrast agent did not compromise contrast visualization. The best mode of administration is the infusion method due to fast homogenous distribution at the lowest dose of 0.12%. Leaving the US contrast agent outside the refrigerator for an hour does not affect the microbubbles.

  4. Reducing urinary tract infections among female clean room workers.

    PubMed

    Su, Shih-Bin; Wang, Jiang-Nan; Lu, Chih-Wei; Guo, How-Ran

    2006-09-01

    A higher prevalence of urinary tract infection (UTI) was observed among clean room workers than among others in our previous study in 2001. We implemented intervention programs for reducing UTI and evaluated their effects 2 years later. We conducted an intervention study in four factories in the industrial park where the previous study was conducted and recruited participants from women workers who received annual health examinations at the clinic of the park. The intervention included health education programs during the new employee orientation and seasonal on-the-job training. We also implemented other measures, including placing posters in the workplace and disseminating knowledge of UTI prevention through e-mail and oral communications. One-on-one education was provided to workers who were found to have UTI in the previous study. All the 1666 qualified workers, including 1414 clean room workers and 252 nonclean room workers, agreed to participate. We found a similar prevalence (both 0.8%) of symptomatic UTIs (patients with clinical symptoms, such as voiding frequency, urgency, and burning sensation during voiding) in clean room and nonclean room workers. In the 366 participants who also participated in the previous study, we found a significant decrease in the prevalence of UTI (from 9.8% to 1.6%) and significant increases in the prevalence of water intake and urine voiding, three times or more during a shift (p < 0.001 for all McNemar tests). The interventions had achieved behavior modification and decreases in the prevalence of UTI.

  5. Neural Control of the Lower Urinary Tract

    PubMed Central

    de Groat, William C.; Griffiths, Derek; Yoshimura, Naoki

    2015-01-01

    This article summarizes anatomical, neurophysiological, pharmacological, and brain imaging studies in humans and animals that have provided insights into the neural circuitry and neurotransmitter mechanisms controlling the lower urinary tract. The functions of the lower urinary tract to store and periodically eliminate urine are regulated by a complex neural control system in the brain, spinal cord, and peripheral autonomic ganglia that coordinates the activity of smooth and striated muscles of the bladder and urethral outlet. The neural control of micturition is organized as a hierarchical system in which spinal storage mechanisms are in turn regulated by circuitry in the rostral brain stem that initiates reflex voiding. Input from the forebrain triggers voluntary voiding by modulating the brain stem circuitry. Many neural circuits controlling the lower urinary tract exhibit switch-like patterns of activity that turn on and off in an all-or-none manner. The major component of the micturition switching circuit is a spinobulbospinal parasympathetic reflex pathway that has essential connections in the periaqueductal gray and pontine micturition center. A computer model of this circuit that mimics the switching functions of the bladder and urethra at the onset of micturition is described. Micturition occurs involuntarily in infants and young children until the age of 3 to 5 years, after which it is regulated voluntarily. Diseases or injuries of the nervous system in adults can cause the re-emergence of involuntary micturition, leading to urinary incontinence. Neuroplasticity underlying these developmental and pathological changes in voiding function is discussed. PMID:25589273

  6. Diagnosis of neonatal group B Streptococcus sepsis by nested-PCR of residual urine samples

    PubMed Central

    Cezarino, Bruno Nicolino; Yamamoto, Lidia; Del Negro, Gilda Maria Barbaro; Rocha, Daisy; Okay, Thelma Suely

    2008-01-01

    Group B streptococcus (GBS) remains the most common cause of early-onset sepsis in newborns. Laboratory gold-standard, broth culture methods are highly specific, but lack sensitivity. The aim of this study was to validate a nested-PCR and to determine whether residue volumes of urine samples obtained by non invasive, non sterile methods could be used to confirm neonatal GBS sepsis. The nested-PCR was performed with primers of the major GBS surface antigen. Unavailability of biological samples to perform life supporting exams, as well as others to elucidate the etiology of infections is a frequent problem concerning newborn patients. Nevertheless, we decided to include cases according to strict criteria: newborns had to present with signs and symptoms compatible with GBS infection; at least one of the following biological samples had to be sent for culture: blood, urine, or cerebrospinal fluid; availability of residue volumes of the samples sent for cultures, or of others collected on the day of hospitalization, prior to antibiotic therapy prescription, to be analyzed by PCR; favorable outcome after GBS empiric treatment. In only one newborn GBS infection was confirmed by cultures, while infection was only presumptive in the other three patients (they fulfilled inclusion criteria but were GBS-culture negative). From a total of 12 biological samples (5 blood, 3 CSF and 4 urine specimen), eight were tested by culture methods (2/8 were positive), and 8 were tested by PCR (7/8 were positive), and only 4 samples were simultaneously tested by both methods (1 positive by culture and 3 by PCR). In conclusion, although based on a restricted number of neonates and samples, our results suggest that the proposed nested-PCR might be used to diagnose GBS sepsis as it has successfully amplified the three types of biological samples analyzed (blood, urine and cerebrospinal fluid), and was more sensitive than culture methods as PCR in urine confirmed diagnosis in all four patients. Moreover, PCR has enabled us to use residue volumes of urine samples collected by non invasive, non sterile methods, what is technically adequate as GBS is not part of the normal urine flora, thus avoiding invasive procedures such as suprapubic bladder punction or transurethral catheterization. At the same time, the use of urine instead of blood samples could help preventing newborns blood spoliation. PMID:24031170

  7. Documenting the kinetic time course of lambda-cyhalothrin metabolites in orally exposed volunteers for the interpretation of biomonitoring data.

    PubMed

    Khemiri, Rania; Côté, Jonathan; Fetoui, Hamadi; Bouchard, Michèle

    2017-07-05

    Lambda-cyhalothrin is a pyrethroid pesticide largely used in agriculture. Exposure assessment can be performed by measuring key urinary metabolites. For a proper use of biomonitoring data, it is however important to gain information on the toxicokinetics of these key biomarkers of exposure. A human volunteer study was performed to document the plasma and urinary time courses of major lambda-cyhalothrin metabolites. Seven volunteers ingested 0.025mgkg -1 body weight of lambda-cyhalothrin. Blood samples were withdrawn prior to dosing and at fixed time periods over the 72 h-period following ingestion and complete urine voids were collected pre-exposure and at pre-established intervals over 84h post-dosing. The cis-3-(2-chloro-3,3,3-trifluoroprop-1-en-1-yl)-2,2-dimethylcyclopropanecarboxylic acid (CFMP) and 3-phenoxybenzoic acid (3-PBA) metabolites were quantified in these samples. Plasma concentrations of CFMP and 3-PBA increased rapidly after ingestion, with average peak values at 3.1 and 4.0h post-dosing, respectively; subsequent elimination phase showed a rapid decay with a mean half-life (t ½ ) of ≈5.3 and 6.4h for CFMP and 3-PBA, respectively. Urinary rate time courses displayed a profile similar to the plasma concentration-time curves with corresponding mean t ½ of ≈4.2 and 5.9h. In the 84-h period post-treatment, on average 21% of lambda-cyhalothrin dose were excreted in urine as CFMP as compared to 30% as 3-PBA. Overall, CFMP and 3-PBA metabolites were confirmed to be major metabolites of lambda-cyhalothrin and exhibited similar kinetics with short half-lives; they thus both appear as useful biomarkers of exposure to lambda-cyhalothrin in humans. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Elevated plasma and urinary concentrations of green tea catechins associated with improved plasma lipid profile in healthy Japanese women.

    PubMed

    Takechi, Ryusuke; Alfonso, Helman; Hiramatsu, Naoko; Ishisaka, Akari; Tanaka, Akira; Tan, La'Belle; Lee, Andy H

    2016-03-01

    This study investigated green tea catechins in plasma and urine and chronic disease biomarkers. We hypothesized that plasma and urinary concentration of green tea catechins are associated with cardiovascular disease and diabetes biomarkers. First void urine and fasting plasma samples were collected from 57 generally healthy females aged 38 to 73 years (mean, 52 ± 8 years) recruited in Himeji, Japan. The concentrations of plasma and urinary green tea catechins were determined by liquid chromatography coupled with mass tandem spectrometer. Low-density lipoprotein (LDL) cholesterol, high-density lipoprotein (HDL) cholesterol, triglyceride, glucose, insulin, glycated hemoglobin, and C-reactive protein in plasma/serum samples were analyzed by a commercial diagnostic laboratory. Statistical associations were assessed using Spearman correlation coefficients. The results showed weak associations between plasma total catechin and triglyceride (r = -0.30) and LDL cholesterol (r = -0.28), whereas plasma (-)-epigallocatechin-3-gallate, (-)-epigallocatechin, (-)-epicatechin-3-gallate, and (-)-epicatechin exhibited weak to moderate associations with triglyceride or LDL cholesterol, but little associations with HDL cholesterol, body fat, and body mass index were evident. Urinary total catechin was weakly associated with triglyceride (r = -0.19) and LDL cholesterol (r = -0.15), whereas urinary (-)-epigallocatechin-3-gallate (r = -0.33), (-)-epigallocatechin (r = -0.23), and (-)-epicatechin-3-gallate (r = -0.33) had weak to moderate correlations with triglyceride and similarly with body fat and body mass index. Both plasma (r = -0.24) and urinary (r = -0.24) total catechin, as well as individual catechins, were weakly associated with glycated hemoglobin. Plasma total and individual catechins were weakly to moderately associated with C-reactive protein, but not the case for urinary catechins. In conclusion, we found weak to moderate associations between plasma and urinary green tea catechin concentrations and plasma biomarkers of cardiovascular disease and diabetes. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Urinary nandrolone metabolite detection after ingestion of a nandrolone precursor.

    PubMed

    Watson, Phillip; Judkins, Catherine; Houghton, Ed; Russell, Caroline; Maughan, Ronald J

    2009-04-01

    Quantities of various anabolic/androgenic steroids have been found in dietary supplements without their presence being disclosed on the label. The aim of this study was to quantify the excretion patterns of the diagnostic metabolites, 19-norandrosterone (19-NA), and 19-noretiocholanolone (19-NE) after ingestion of small doses of 19-nor-4-androstene-3,17-dione (19-norandrostenedione). Eleven males and nine females entered the laboratory in the morning after an overnight fast. An initial urine sample was collected, and volunteers then ingested 500 mL of water containing 5 g of creatine monohydrate and 1.0, 2.5, or 5.0 microg of 19-norandrostenedione. The volume of each urine void was measured, and an aliquot was taken. Samples were analyzed for the metabolites 19-NA and 19-NE by GCMS. Baseline urinary 19-NA concentrations were 0.19 +/- 0.14 ng x mL. Ingestion of the supplement resulted in peak mean urinary 19-NA concentrations of 0.68 +/- 0.36, 1.56 +/- 0.86, and 3.89 +/- 3.11 ng.mL in the 1.0-, 2.5-, or 5.0-microg trials, respectively. Under current WADA regulations, ingestion of the 1.0-microg dose produced 0 positive doping tests, 5 subjects (20%) tested positive in the 2.5-microg trial, and 15 subjects (75%) had urinary 19-NA concentrations exceeding 2 ng x mL after ingesting creatine containing 5.0 microg of the steroid. The recovery of the ingested dose was highly variable between individuals, with values ranging from 11% to 84% (mean +/- SD = 47% +/- 18%). Ingestion of trace amounts of 19-norandrostenedione can result in transient elevations of urinary 19-NA and 19-NE concentrations. The addition of as little as 2.5 microg of 19-norandrostenedione to a supplement (0.00005% contamination) appears sufficient to result in a doping violation in some individuals.

  10. Development of a robust field technique to quantify the air-void distribution in fresh concrete.

    DOT National Transportation Integrated Search

    2013-07-01

    In order to make concrete frost durable it is common to provide a small and well distributed air void system. Current measuring techniques require weeks to complete on hardened and polished samples of concrete. This report presents the results of a n...

  11. Does the Exposure of Urine Samples to Air Affect Diagnostic Tests for Urine Acidification?

    PubMed Central

    Yi, Joo-Hark; Shin, Hyun-Jong; Kim, Sun-Moon; Han, Sang-Woong; Oh, Man-Seok

    2012-01-01

    Summary Background and objectives For accurate measurement of pH, urine collection under oil to limit the escape of CO2 on air exposure is recommended. This study aims to test the hypothesis that urine collection under oil is not necessary in acidic urine in which bicarbonate and CO2 are minor buffers, because loss of CO2 would have little effect on its pH. Design, setting, participants, & measurements One hundred consecutive random urine samples were collected under oil and analyzed for pH, pCO2, and HCO3− immediately and after 5 minutes of vigorous shaking in uncovered flasks to allow CO2 escape. Results The pH values in 97 unshaken samples ranged from 5.03 to 6.83. With shaking, urine pCO2 decreased by 76%, whereas urine HCO3− decreased by 60%. Meanwhile, urine baseline median pH (interquartile range) of 5.84 (5.44–6.25) increased to 5.93 (5.50–6.54) after shaking (ΔpH=0.12 [0.07–0.29], P<0.001). ΔpH with pH≤6.0 was significantly lower than the ΔpH with pH>6.0 (0.08 [0.05–0.12] versus 0.36 [0.23–0.51], P<0.001). Overall, the lower the baseline pH, the smaller the ΔpH. Conclusions The calculation of buffer reactions in a hypothetical acidic urine predicted a negligible effect on urine pH on loss of CO2 by air exposure, which was empirically proven by the experimental study. Therefore, exposure of urine to air does not substantially alter the results of diagnostic tests for urine acidification, and urine collection under oil is not necessary. PMID:22700881

  12. The Diagnostic Accuracy of Urine-Based Xpert MTB/RIF in HIV-Infected Hospitalized Patients Who Are Smear-Negative or Sputum Scarce

    PubMed Central

    Peter, Jonathan G.; Theron, Grant; Muchinga, Tapuwa E.; Govender, Ureshnie; Dheda, Keertan

    2012-01-01

    Background Hospitals in sub-Saharan Africa are inundated with HIV-infected patients and tuberculosis (TB) is the commonest opportunistic infection in this sub-group. Up to one third of TB-HIV co-infected patients fail to produce a sputum sample (sputum scarce) and diagnosis is thus often delayed or missed. We investigated the sensitivity of urine-based methods (Xpert MTB/RIF, LAM strip test and LAM ELISA) in such patients. Methodology/Principal Findings 281 HIV-infected hospitalised patients with clinically suspected TB provided a spot urine sample. The reference standard was culture positivity for Mycobacterium tuberculosis on ≥1 sputum or extra-pulmonary sample. MTB/RIF was performed using 1 ml of both unprocessed and, when possible, concentrated urine. Each unconcentrated urine sample was also tested using the Clearview LAM ELISA and Alere LAM strip test. 42% (116/242) of patients had culture-proven TB. 18% (20/54) were sputum scarce. In sputum-scarce patients, the sensitivity of urine MTB/RIF and LAM ELISA was 40% (95%CI: 22–61) and 60% (95%CI: 39–78), respectively. Urine MTB/RIF specificity was 98% (95%CI: 95–100). Combined sensitivity of urine LAM ELISA and MTB/RIF was better than MTB/RIF alone [MTB/RIF and LAM: 70% (95%CI: 48–85) vs. MTB/RIF: 40% (95%CI: 22–61), p = 0.03]. Significant predictors of urine MTB/RIF positivity were CD4<50 cells/ml (p = 0.001), elevated protein-to-creatinine ratio (p<0.001) and LAM ELISA positivity (p<0.001). Urine centrifugation and pelleting significantly increased the sensitivity of MTB/RIF over unprocessed urine in paired samples [42% (95%CI: 26–58) vs. 8% (95%CI: 0–16), p<0.001]. Urine MTB/RIF-generated CT values correlated poorly with markers of bacillary burden (smear grade and time-to-positivity). Conclusions/Significance This preliminary study indicates that urine-based MTB/RIF, alone or in combination with LAM antigen detection, may potentially aid the diagnosis of TB in HIV-infected patients with advanced immunosuppression when sputum-based diagnosis is not possible. Concentration of urine prior to MTB/RIF-testing significantly improves sensitivity. PMID:22815718

  13. [Usefulness of urethral endoprosthesis in the management of urinary retention after brachytherapy for localized prostate cancer].

    PubMed

    Kerkeni, W; Chahwan, C; Lenormand, C; Dubray, B; Benyoucef, A; Pfister, C

    2014-03-01

    Brachytherapy is a possible treatment for localized low risk prostate cancer. Although this option is minimally invasive, some side effects may occur. Acute retention of urine (ARU) has been observed in 5% to 22% of cases and can be prevented in most cases by alpha-blocker treatment. Several alternatives have been reported in the literature for the management of ARU following brachytherapy: prolonged suprapubic catheterization, transurethral resection of the prostate and also intermittent self-catheterization. The authors report an original endoscopic approach, using urethral endoprosthesis, with a satisfactory voiding status. Copyright © 2013. Published by Elsevier Masson SAS.

  14. Y-type urethral duplication: an unusual variant of a rare anomaly.

    PubMed

    Kumaravel, S; Senthilnathan, R; Sankkarabarathi, C; Bagdi, R K; Soundararajan, S; Prasad, N

    2004-12-01

    Urethral duplications are rare anomalies. We present a 3-year-old continent boy passing urine since birth per anus while voiding from penis. Micturating cystourethrogram, retrograde urethrogram and cystoscopy revealed a Y connection between the posterior urethra and anal canal. The accessory channel was excised by a perineal approach. Histopathology revealed that the tract was lined by transitional epithelium, proving that it was indeed a case of urethral duplication; hence, we suggest that all urethroanal fistulas are not variants of anorectal malformations. Certain of these fistulas should be considered as variants of Y-type urethral duplication even if the orthotopic urethra is normal.

  15. Determination of γ-hydroxybutyrate in human urine samples by ion exclusion and ion exchange two-dimensional chromatography system.

    PubMed

    Liu, Junwei; Deng, Zhifen; Zhu, Zuoyi; Wang, Yong; Wang, Guoqing; Sun, Yu-An; Zhu, Yan

    2017-12-15

    A two-dimensional ion chromatography system was developed for the determination of γ-hydroxybutyrate (GHB) in human urine samples. Ion exclusion chromatography was used in the first dimensional separation for elimination of urine matrices and detection of GHB above 10mgL -1 , ion exchange chromatography was used in the second dimensional separation via column-switching technique for detection of GHB above 0.08mgL -1 . Under the optimized chromatographic conditions, the ion exclusion and ion exchange chromatography separation system exhibited satisfactory repeatability (RSD<3.1%, n=6) and good linearity in the range of 50-1000mgL -1 and 0.5-100mgL -1 , respectively. By this method, concentrations of GHB in the selected human urine samples were detected in the range of 0-1.57mgL -1 . The urine sample containing 0.89mgL -1 GHB was selected to evaluate the accuracy; the spiked recoveries of GHB were 95.9-102.8%. The results showed that the two-dimensional ion chromatography system was convenient and practical for the determination of GHB in human urine samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Real-Time Polymerase Chain Reaction for Detection of Schistosoma DNA in Small-Volume Urine Samples Reflects Focal Distribution of Urogenital Schistosomiasis in Primary School Girls in KwaZulu Natal, South Africa

    PubMed Central

    Pillay, Pavitra; Taylor, Myra; Zulu, Siphosenkosi G.; Gundersen, Svein G.; Verweij, Jaco J.; Hoekstra, Pytsje; Brienen, Eric A. T.; Kleppa, Elisabeth; Kjetland, Eyrun F.; van Lieshout, Lisette

    2014-01-01

    Schistosoma haematobium eggs and Schistosoma DNA levels were measured in urine samples from 708 girls recruited from 18 randomly sampled primary schools in South Africa. Microscopic analysis of two 10-mL urine subsamples collected on three consecutive days confirmed high day-to-day variation; 103 (14.5%) girls had positive results at all six examinations, and at least one positive sample was seen in 225 (31.8%) girls. Schistosoma-specific DNA, which was measured in a 200-μL urine subsample by using real-time polymerase chain reaction, was detected in 180 (25.4%) cases, and levels of DNA corresponded significantly with average urine egg excretion. In concordance with microscopic results, polymerase chain reaction results were significantly associated with history of gynecologic symptoms and confirmed highly focal distribution of urogenital schistosomiasis. Parasite-specific DNA detection has a sensitivity comparable to single urine microscopy and could be used as a standardized high-throughput procedure to assess distribution of urogenital schistosomiasis in relatively large study populations by using small sample volumes. PMID:24470560

  17. Development of Technologies for Early Detection and Stratification of Breast Cancer

    DTIC Science & Technology

    2014-10-01

    cancer. Similar screening has been done in urine samples with CYR61 and LCN2 (Figure 2a-b). The Moses lab provided breast cancer urine samples and two ...diseased samples, while CYR61 appears to have two different populations whereas diseased urine samples have lower levels of the protein present. More... system for eDAR so that each isolated cell can be deposited into a well of a 96-well plate for high-throughput downstream single-cell digital

  18. DNA typing for personal identification of urine after long-term preservation for testing in doping control.

    PubMed

    Aoki, Kimiko; Tanaka, Hiroyuki; Ueki, Makoto

    2017-08-01

    When the tampering of a urine sample is suspected in doping control, personal identification of the sample needs to be determined by short tandem repeat (STR) analysis using DNA. We established a method for extracting DNA from urine samples stored at -20 °C without using any additives or procedures, which is consistent with how samples are required to be managed for doping control. The method, using the Puregene® Blood Core kit followed by NucleoSpin® gDNA Clean-up or NucleoSpin® gDNA Clean-up XS kit, does not need any special instrument and can provide a purified extract with high-quality DNA from up to 40 mL of urine suitable for STR analysis using an AmpFlSTR® Identifiler® PCR amplification kit. Storing urine at -20 °C is detrimental to the stability of DNA. The DNA concentration of preserved urine could not be predicted by specific gravity or creatinine level at the time of urine collection. The DNA concentration of a purified extract (10 μL) was required to be >0.06 ng/μL to ensure a successful STR analysis. Thus, the required extraction volumes of urine preserved for 3-7 years at -20 °C were estimated to be 30 mL and 20 mL to succeed in at least 86% of men and 91% of women, respectively. Considering the long half-life of DNA during long-term preservation, our extraction method is applicable to urine samples stored even for 10 years, which is currently the storage duration allowed (increased from 8 years) before re-examination in doping control. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  19. Immunoreactive LH in long-term frozen human urine samples.

    PubMed

    Singh, Gurmeet Kaur Surindar; Jimenez, Mark; Newman, Ron; Handelsman, David J

    2014-04-01

    Urine provides a convenient non-invasive alternative to blood sampling for measurement of certain hormones. Urinary luteinizing hormone (LH) measurements have been used for endocrinology research and anti-doping testing. However, the commercially available LH immunoassays are developed and validated for human blood samples but not urine so that LH assays intended for use with urine samples need thorough validation. Therefore, the present study evaluated the measurement of urinary LH immunoreactivity using previously validated immunofluorometric (IF) and immunochemiluminometric (ICL) LH assays after prolonged frozen storage. LH was measured in serial urine samples following administration of a single injection of one of two doses of recombinant human chorionic hormone (rhCG) with assays run at the end of study (2008) and again after four years of frozen (-20 °C) storage where samples were stored without adding preservatives. The ICL assay showed quantitatively reproducible LH measurements after prolonged -20 °C storage. However, the IF immunoassay gave consistently lower LH levels relative to ICL (2008) with a further proportionate reduction after four years of sample storage (2012). Yet, both the assays displayed similar patterns of the time-course of urine LH measurement both before and after four years of frozen storage. In conclusion, we found that both immunoassays are suitable for urinary LH measurements with ICL assay being more robust for quantitative urinary LH measurement such as for anti-doping purposes, whereas the IF could be applicable for research studies where urine LH levels are compared within-study but not in absolute terms. Copyright © 2013 John Wiley & Sons, Ltd.

  20. Preparation of magnetic ODS-PAN thin-films for microextraction of quetiapine and clozapine in plasma and urine samples followed by HPLC-UV detection.

    PubMed

    Li, Dan; Zou, Juan; Cai, Pei-Shan; Xiong, Chao-Mei; Ruan, Jin-Lan

    2016-06-05

    In this study, conventional thin-film microextraction (TFME) was endowed with magnetic by introducing superparamagnetic SiO2@Fe3O4 nanoparticles in thin-films. Novel magnetic octadecylsilane (ODS)-polyacrylonitrile (PAN) thin-films were prepared by spraying, and used for the microextraction of quetiapine and clozapine in plasma and urine samples, followed by the detection of HPLC-UV. The influencing factors on the extraction efficiency of magnetic ODS-PAN TFME, including pH, extraction time, desorption solvent, desorption time, and ion strength were investigated systematically. Under the optimal conditions, both analytes showed good linearity over ranges of 0.070-9.000μgmL(-1) and 0.012-9.000μgmL(-1) in plasma and urine samples, respectively, with correlation coefficients (R(2)) above 0.9990. Limits of detection (LODs) for quetiapine in plasma and urine samples were 0.013 and 0.003μgmL(-1), respectively. LODs for clozapine in plasma and urine samples were 0.015 and 0.003μgmL(-1), respectively. The relative standard deviations (RSDs) for quetiapine and clozapine were less than 9.23%. After the validation, the protocol was successfully applied for the determination of quetiapine and clozapine in patients' plasma and urine samples with satisfactory recoveries between 99-110%. The proposed magnetic ODS-PAN TFME was very simple, fast and easy to handle. It showed high potential as a powerful pretreatment technology for routine therapeutic drug monitoring (TDM) in plasma and urine samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Urine benzodiazepines screening of involuntarily drugged and robbed or raped patients.

    PubMed

    Boussairi, A; Dupeyron, J P; Hernandez, B; Delaitre, D; Beugnet, L; Espinoza, P; Diamant-Berger, O

    1996-01-01

    This study involved 35 patients who claimed to have been drugged before being robbed or raped, despite urine negative toxicologic screening by immunoenzymatic methods. The urines were frozen for further investigations, including enzymatic hydrolysis of urinary conjugates, liquid-solid extraction and, finally, immunoenzymatic screening of concentrated urine extract. Urine benzodiazepines were analyzed by immunoenzymatic assay before and after enzymatic hydrolysis combined with extraction. On direct immunoenzymatic screening, 17 of the 35 urine samples were benzodiazepine positive. Enrichment of preserved specimens improved the detection threshold from 200 ng/mL to 50 ng/mL and 10 of the 18 negative urines became positive. This method allowed us to demonstrate the benzodiazepines in half of previously negative urine samples. Benzodiazepine screening is particularly problematic because of low dosage, rapid elimination, failure to detect conjugated metabolites by immunoenzymatic reagents and high threshold of sensitivity for certain substances.

  2. Microanalyzer for Biomonitoring of Lead (Pb) in Blood and Urine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yantasee, Wassana; Timchalk, Chuck; Lin, Yuehe

    2007-01-01

    Biomonitoring of lead (Pb) in blood and urine enables quantitative evaluation of human occupational and environmental exposures to Pb. The state-of-the-art ICP-MS instruments analyze metals in laboratories, resulting in lengthy turn around time, and are expensive. In response to the growing need for metal analyzer for on-site, real-time monitoring of trace metals in individuals, we developed a portable microanalyzer based on flow-injection/adsorptive stripping voltammetry and used it to analyze Pb in rat blood and urine. Fouling of electrodes by proteins often prevents the effective use of electrochemical sensors in biological matrices. Minimization of such fouling was accomplished with the suitablemore » sample pretreatment and the turbulent flowing of Pb contained blood and urine onto the glassy electrode inside the microanalyzer, which resulted in no apparent electrode fouling even when the samples contained 50% urine or 10% blood by volume. There was no matrix effect on the voltammetric Pb signals even when the samples contained 10% blood or 10% urine. The microanalyzer offered linear concentration range relevant to Pb exposure levels in human (0-20 ppb in 10%-blood samples, 0-50 ppb in 50%-urine samples). The device had excellent sensitivity and reproducibility; Pb detection limits were 0.54 ppb and 0.42 ppb, and % RSDs were 4.9 and 2.4 in 50%-urine and 10%-blood samples, respectively. It offered a high throughput (3 min per sample) and had economical use of samples (60 ?L per measurement), making the collection of blood being less invasive especially to children, and had low reagent consumption (1 ?g of Hg per measurement), thus minimizing the health concerns of mercury use. Being miniaturized in size, the microanalyzer is portable and field-deployable. Thus, it has a great potential to be the next-generation analyzer for biomonitoring of toxic metals.« less

  3. Integrated preservation and sample clean up procedures for studying water ingestion by recreational swimmers via urinary biomarker determination.

    PubMed

    Cantú, Ricardo; Shoemaker, Jody A; Kelty, Catherine A; Wymer, Larry J; Behymer, Thomas D; Dufour, Alfred P; Magnuson, Matthew L

    2017-08-22

    The use of cyanuric acid as a biomarker for ingestion of swimming pool water may lead to quantitative knowledge of the volume of water ingested during swimming, contributing to a better understanding of disease resulting from ingestion of environmental contaminants. When swimming pool water containing chlorinated cyanurates is inadvertently ingested, cyanuric acid is excreted quantitatively within 24 h as a urinary biomarker of ingestion. Because the volume of water ingested can be quantitatively estimated by calculation from the concentration of cyanuric acid in 24 h urine samples, a procedure for preservation, cleanup, and analysis of cyanuric acid was developed to meet the logistical demands of large scale studies. From a practical stand point, urine collected from swimmers cannot be analyzed immediately, given requirements of sample collection, shipping, handling, etc. Thus, to maintain quality control to allow confidence in the results, it is necessary to preserve the samples in a manner that ensures as quantitative analysis as possible. The preservation and clean-up of cyanuric acid in urine is complicated because typical approaches often are incompatible with the keto-enol tautomerization of cyanuric acid, interfering with cyanuric acid sample preparation, chromatography, and detection. Therefore, this paper presents a novel integration of sample preservation, clean-up, chromatography, and detection to determine cyanuric acid in 24 h urine samples. Fortification of urine with cyanuric acid (0.3-3.0 mg/L) demonstrated accuracy (86-93% recovery) and high reproducibility (RSD < 7%). Holding time studies in unpreserved urine suggested sufficient cyanuric acid stability for sample collection procedures, while longer holding times suggested instability of the unpreserved urine. Preserved urine exhibited a loss of around 0.5% after 22 days at refrigerated storage conditions of 4 °C. Published by Elsevier B.V.

  4. Urinary incontinence in working women: a comparison study.

    PubMed

    Palmer, Mary H; Fitzgerald, Sheila

    2002-12-01

    To compare the findings of two surveys concerning the nature of urinary incontinence and management strategies used by full-time employed working women. The first study was conducted in an urban academic setting with a survey distributed to 2000 women. The second study was conducted with 500 women in a rural pottery manufacturing facility. Twenty-one percent of the women working in an academic setting (group A) and 29% (p = 0.002) of the women working in a manufacturing setting (group B) reported being incontinent of urine at least monthly. More women in group B reported antecedents mixed incontinence (i.e., antecedent to both stress and urge incontinence). More women in group B also used panty liners to manage urine loss (p = 0.003), whereas more women in group A used voiding schedules (p = 0.008) and pelvic muscle exercises (p = 0.04). More women in group A reported that they did not know if their incontinence could improve (40% vs. 1%, p = 0.00). The majority in both groups said that getting treatment was of no or little importance, yet, overwhelmingly, most women (group A 81%; group B 86%) wanted more information about incontinence. Incontinence is a prevalent condition in working women. Discrepancies exist in the nature of the urine loss and strategies used to manage incontinence. Treatment also differs for those women who report urine loss to healthcare providers. Most women want to learn more about incontinence. Secondary prevention strategies need to be tailored and tested to meet symptoms and concerns for women in different work settings.

  5. Diagnosis and effects of urine contamination in cooled-extended stallion semen.

    PubMed

    Ellerbrock, R; Canisso, I; Feijo, L; Lima, F; Shipley, C; Kline, K

    2016-04-15

    Urospermia is known to affect semen quality in many mammals, including stallions. Determinations of semen pH and creatinine and urea concentrations have been used to diagnose urine contamination in raw stallion semen. Unfortunately, practitioners suspecting urine contamination in cooled-shipped samples have no proven means to confirm the presence of urine. Therefore, the objectives of this study were (1) to assess the effects of urine contamination on sperm motility of extended fresh and cooled-stored stallion semen, (2) to evaluate the usefulness of semen color, odor, pH, and creatinine and urea concentrations for urospermia diagnosis, and (3) to evaluate the accuracy of a commercial blood urea nitrogen test strip in diagnosing urine contamination in extended-cooled stallion semen. Thirty-seven ejaculates were obtained from 11 stallions with no history of urospermia before division into 5 mL aliquots, and contamination with stallion urine. Each resulting sample was assessed for sperm motility, color, odor, pH, creatinine, and urea nitrogen concentration using both a semiquantitative test strip (Azostix), and a quantitative automated analyzer before and after cooling for 24 hour. Sperm motility parameters, pH, and creatinine and urea concentrations were analyzed using mixed models. Urine contamination decreased total and progressive motility in all samples before and after cooling (P < 0.05). Mean control total motility was 80% at 0 hour and 67% at 24 hours, whereas urine-contaminated samples ranged from 30% to 71% at 0 hour and 27% to 61% at 24 hours. Control mean urea (29 mg/dL) and creatinine (0.6 mg/dL) concentrations were significantly different (P < 0.05) from all urine-contaminated samples (158 mg/dL and 11.6 mg/dL, respectively) at 0 hour. Similarly, control mean urea (8 mg/dL) and creatinine (0.9 mg/dL) concentrations were significantly different than all urine-contaminated samples at 24 hours. Odor assessment presented moderate sensitivity (65%) and high specificity (100%), while color assessment presented low sensitivity (47%) and moderate specificity (79%) for urine in extended semen. Azostix strips were highly sensitive (95%) and specific (97%). Assessment of color, odor, and pH are not reliable methods to diagnose urine in experimentally contaminated cooled-stored stallion semen. Sperm motility parameters (in raw and cooled semen) are significantly reduced by the presence of urine in a concentration dependent. The results of the present study indicated that determination of urea and creatinine concentrations can be used to diagnose urospermia and that Azostix can be used as a point care method for diagnosing urine contamination in extended cooled stallion semen. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. [Examination about utility of a Streptococcus pneumoniae capsular antigen swiftness search kit urine in a pneumonia patient].

    PubMed

    Hashikita, Giichi; Yamaguti, Toshiyuki; Tachi, Yoshimi; Kishi, Etsuko; Kawamura, Toru; Takahashi, Shun; Arai, Yukie; Koyama, Sachie; Huruhata, Toshihumi; Itabashi, Akira; Oka, Yoko; Yamazaki, Tsutomu; Maesaki, Sigefumi

    2005-01-01

    We investigated the usefullness of Binax NOW urine antigen test, an immunochromatographic assay that binds any soluble Streptococcus pneumoniae antigen (C polysaccharide) for the diagnosis of penumoniae form September 2003 to March 2005. We used 372 samples form the patinets with pneumoniae diagnosed for blood or sputum cultuter or gram-stained sputum smear. Out of 24 culture positive specimens, Binax NOW urine antigen test, showed positive in 18 (75%) specimens. The sensitivity of sputum and blood culture was 71.7% and 83.3%, respectively. Binax NOW urine antigen test was seemed false positives in 55 samples, false negatives in 6 samples. The specificity of Binax NOW urine antigen test was evaluated 84.1%. Overall agreement among tests was 83.6%. When compared to culture, false negative urine antigen may be the result of colonizing S. pneumoniae in sputum or pneumonia caused by an agent other than S. pneumoniae. CRP values for cases were both urine antigen and culture were positive ranged from 40 mg/dl to 10 mg/dl while urine antigen and culture negative cases were predominantly less than 10 mg/dl. Positive blood and pleural fluid culture cases were consistently associated with strongly positive urine antigen tests. Non-agreement between urine antigen, culture, and microscopy may be the result of specimen quality, labile nature of S. pneumoniae and antimicrobial therapy.

  7. Union operation image processing of data cubes separately processed by different objective filters and its application to void analysis in an all-solid-state lithium-ion battery.

    PubMed

    Yamamoto, Yuta; Iriyama, Yasutoshi; Muto, Shunsuke

    2016-04-01

    In this article, we propose a smart image-analysis method suitable for extracting target features with hierarchical dimension from original data. The method was applied to three-dimensional volume data of an all-solid lithium-ion battery obtained by the automated sequential sample milling and imaging process using a focused ion beam/scanning electron microscope to investigate the spatial configuration of voids inside the battery. To automatically fully extract the shape and location of the voids, three types of filters were consecutively applied: a median blur filter to extract relatively larger voids, a morphological opening operation filter for small dot-shaped voids and a morphological closing operation filter for small voids with concave contrasts. Three data cubes separately processed by the above-mentioned filters were integrated by a union operation to the final unified volume data, which confirmed the correct extraction of the voids over the entire dimension contained in the original data. © The Author 2015. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Fully automated methods for the determination of hydrochlorothiazide in human plasma and urine.

    PubMed

    Hsieh, J Y; Lin, C; Matuszewski, B K; Dobrinska, M R

    1994-12-01

    LC assays utilizing fully automated sample preparation procedures on Zymark PyTechnology Robot and BenchMate Workstation for the quantification of hydrochlorothiazide (HCTZ) in human plasma and urine have been developed. After aliquoting plasma and urine samples, and adding internal standard (IS) manually, the robot executed buffer and organic solvent addition, liquid-liquid extraction, solvent evaporation and on-line LC injection steps for plasma samples, whereas, BenchMate performed buffer and organic solvent addition, liquid-liquid and solid-phase extractions, and on-line LC injection steps for urine samples. Chromatographic separations were carried out on Beckman Octyl Ultrasphere column using the mobile phase composed of 12% (v/v) acetonitrile and 88% of either an ion-pairing reagent (plasma) or 0.1% trifluoroacetic acid (urine). The eluent from the column was monitored with UV detector (271 nm). Peak heights for HCTZ and IS were automatically processed using a PE-Nelson ACCESS*CHROM laboratory automation system. The assays have been validated in the concentration range of 2-100 ng ml-1 in plasma and 0.1-20 micrograms ml-1 in urine. Both plasma and urine assays have the sensitivity and specificity necessary to determine plasma and urine concentrations of HCTZ from low dose (6.25/12.5 mg) administration of HCTZ to human subjects in the presence or absence of losartan.

  9. Combined quantification of paclitaxel, docetaxel and ritonavir in human feces and urine using LC-MS/MS.

    PubMed

    Hendrikx, Jeroen J M A; Rosing, Hilde; Schinkel, Alfred H; Schellens, Jan H M; Beijnen, Jos H

    2014-02-01

    A combined assay for the determination of paclitaxel, docetaxel and ritonavir in human feces and urine is described. The drugs were extracted from 200 μL urine or 50 mg feces followed by high-performance liquid chromatography analysis coupled with positive ionization electrospray tandem mass spectrometry. The validation program included calibration model, accuracy and precision, carry-over, dilution test, specificity and selectivity, matrix effect, recovery and stability. Acceptance criteria were according to US Food and Drug Administration guidelines on bioanalytical method validation. The validated range was 0.5-500 ng/mL for paclitaxel and docetaxel, 2-2000 ng/mL for ritonavir in urine, 2-2000 ng/mg for paclitaxel and docetaxel, and 8-8000 ng/mg for ritonavir in feces. Inter-assay accuracy and precision were tested for all analytes at four concentration levels and were within 8.5% and <10.2%, respectively, in both matrices. Recovery at three concentration levels was between 77 and 94% in feces samples and between 69 and 85% in urine samples. Method development, including feces homogenization and spiking blank urine samples, are discussed. We demonstrated that each of the applied drugs could be quantified successfully in urine and feces using the described assay. The method was successfully applied for quantification of the analytes in feces and urine samples of patients. Copyright © 2013 John Wiley & Sons, Ltd.

  10. Comparison of Depletion Strategies for the Enrichment of Low-Abundance Proteins in Urine.

    PubMed

    Filip, Szymon; Vougas, Konstantinos; Zoidakis, Jerome; Latosinska, Agnieszka; Mullen, William; Spasovski, Goce; Mischak, Harald; Vlahou, Antonia; Jankowski, Joachim

    2015-01-01

    Proteome analysis of complex biological samples for biomarker identification remains challenging, among others due to the extended range of protein concentrations. High-abundance proteins like albumin or IgG of plasma and urine, may interfere with the detection of potential disease biomarkers. Currently, several options are available for the depletion of abundant proteins in plasma. However, the applicability of these methods in urine has not been thoroughly investigated. In this study, we compared different, commercially available immunodepletion and ion-exchange based approaches on urine samples from both healthy subjects and CKD patients, for their reproducibility and efficiency in protein depletion. A starting urine volume of 500 μL was used to simulate conditions of a multi-institutional biomarker discovery study. All depletion approaches showed satisfactory reproducibility (n=5) in protein identification as well as protein abundance. Comparison of the depletion efficiency between the unfractionated and fractionated samples and the different depletion strategies, showed efficient depletion in all cases, with the exception of the ion-exchange kit. The depletion efficiency was found slightly higher in normal than in CKD samples and normal samples yielded more protein identifications than CKD samples when using both initial as well as corresponding depleted fractions. Along these lines, decrease in the amount of albumin and other targets as applicable, following depletion, was observed. Nevertheless, these depletion strategies did not yield a higher number of identifications in neither the urine from normal nor CKD patients. Collectively, when analyzing urine in the context of CKD biomarker identification, no added value of depletion strategies can be observed and analysis of unfractionated starting urine appears to be preferable.

  11. Comparison of Depletion Strategies for the Enrichment of Low-Abundance Proteins in Urine

    PubMed Central

    Filip, Szymon; Vougas, Konstantinos; Zoidakis, Jerome; Latosinska, Agnieszka; Mullen, William; Spasovski, Goce; Mischak, Harald; Vlahou, Antonia; Jankowski, Joachim

    2015-01-01

    Proteome analysis of complex biological samples for biomarker identification remains challenging, among others due to the extended range of protein concentrations. High-abundance proteins like albumin or IgG of plasma and urine, may interfere with the detection of potential disease biomarkers. Currently, several options are available for the depletion of abundant proteins in plasma. However, the applicability of these methods in urine has not been thoroughly investigated. In this study, we compared different, commercially available immunodepletion and ion-exchange based approaches on urine samples from both healthy subjects and CKD patients, for their reproducibility and efficiency in protein depletion. A starting urine volume of 500 μL was used to simulate conditions of a multi-institutional biomarker discovery study. All depletion approaches showed satisfactory reproducibility (n=5) in protein identification as well as protein abundance. Comparison of the depletion efficiency between the unfractionated and fractionated samples and the different depletion strategies, showed efficient depletion in all cases, with the exception of the ion-exchange kit. The depletion efficiency was found slightly higher in normal than in CKD samples and normal samples yielded more protein identifications than CKD samples when using both initial as well as corresponding depleted fractions. Along these lines, decrease in the amount of albumin and other targets as applicable, following depletion, was observed. Nevertheless, these depletion strategies did not yield a higher number of identifications in neither the urine from normal nor CKD patients. Collectively, when analyzing urine in the context of CKD biomarker identification, no added value of depletion strategies can be observed and analysis of unfractionated starting urine appears to be preferable. PMID:26208298

  12. Improved bacterial identification directly from urine samples with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

    PubMed

    Kitagawa, Koichi; Shigemura, Katsumi; Onuma, Ken-Ichiro; Nishida, Masako; Fujiwara, Mayu; Kobayashi, Saori; Yamasaki, Mika; Nakamura, Tatsuya; Yamamichi, Fukashi; Shirakawa, Toshiro; Tokimatsu, Issei; Fujisawa, Masato

    2018-03-01

    Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) contributes to rapid identification of pathogens in the clinic but has not yet performed especially well for Gram-positive cocci (GPC) causing complicated urinary tract infection (UTI). The goal of this study was to investigate the possible clinical use of MALDI-TOF MS as a rapid method for bacterial identification directly from urine in complicated UTI. MALDI-TOF MS was applied to urine samples gathered from 142 suspected complicated UTI patients in 2015-2017. We modified the standard procedure (Method 1) for sample preparation by adding an initial 10 minutes of ultrasonication followed by centrifugation at 500 g for 1 minutes to remove debris such as epithelial cells and leukocytes from the urine (Method 2). In 133 urine culture-positive bacteria, the rate of corresponded with urine culture in GPC by MALDI-TOF MS in urine with standard sample preparation (Method 1) was 16.7%, but the modified sample preparation (Method 2) significantly improved that rate to 52.2% (P=.045). Method 2 also improved the identification accuracy for Gram-negative rods (GNR) from 77.1% to 94.2% (P=.022). The modified Method 2 significantly improved the average MALDI score from 1.408±0.153 to 2.166±0.045 (P=.000) for GPC and slightly improved the score from 2.107±0.061 to 2.164±0.037 for GNR. The modified sample preparation for MALDI-TOF MS can improve identification accuracy for complicated UTI causative bacteria. This simple modification offers a rapid and accurate routine diagnosis for UTI, and may possibly be a substitute for urine cultures. © 2017 Wiley Periodicals, Inc.

  13. Interlaboratory trial for the measurement of total cobalt in equine urine and plasma by ICP-MS.

    PubMed

    Popot, Marie-Agnes; Ho, Emmie N M; Stojiljkovic, Natali; Bagilet, Florian; Remy, Pierre; Maciejewski, Pascal; Loup, Benoit; Chan, George H M; Hargrave, Sabine; Arthur, Rick M; Russo, Charlie; White, James; Hincks, Pamela; Pearce, Clive; Ganio, George; Zahra, Paul; Batty, David; Jarrett, Mark; Brooks, Lydia; Prescott, Lise-Anne; Bailly-Chouriberry, Ludovic; Bonnaire, Yves; Wan, Terence S M

    2017-09-01

    Cobalt is an essential mineral micronutrient and is regularly present in equine nutritional and feed supplements. Therefore, cobalt is naturally present at low concentrations in biological samples. The administration of cobalt chloride is considered to be blood doping and is thus prohibited. To control the misuse of cobalt, it was mandatory to establish an international threshold for cobalt in plasma and/or in urine. To achieve this goal, an international collaboration, consisting of an interlaboratory comparison between 5 laboratories for the urine study and 8 laboratories for the plasma study, has been undertaken. Quantification of cobalt in the biological samples was performed by inductively coupled plasma-mass spectrometry (ICP-MS). Ring tests were based on the analysis of 5 urine samples supplemented at concentrations ranging from 5 up to 500 ng/mL and 5 plasma samples spiked at concentrations ranging from 0.5 up to 25 ng/mL. The results obtained from the different laboratories were collected, compiled, and compared to assess the reproducibility and robustness of cobalt quantification measurements. The statistical approach for the ring test for total cobalt in urine was based on the determination of percentage deviations from the calculated means, while robust statistics based on the calculated median were applied to the ring test for total cobalt in plasma. The inter-laboratory comparisons in urine and in plasma were successful so that 97.6% of the urine samples and 97.5% of the plasma samples gave satisfactory results. Threshold values for cobalt in plasma and urine were established from data only obtained by laboratories involved in the ring test. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Automated biowaste sampling system urine subsystem operating model, part 1

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Mangialardi, J. K.; Rosen, F.

    1973-01-01

    The urine subsystem automatically provides for the collection, volume sensing, and sampling of urine from six subjects during space flight. Verification of the subsystem design was a primary objective of the current effort which was accomplished thru the detail design, fabrication, and verification testing of an operating model of the subsystem.

  15. Rapid screening of selective serotonin re-uptake inhibitors in urine samples using solid-phase microextraction gas chromatography-mass spectrometry.

    PubMed

    Salgado-Petinal, Carmen; Lamas, J Pablo; Garcia-Jares, Carmen; Llompart, Maria; Cela, Rafael

    2005-07-01

    In this paper a solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) method is proposed for a rapid analysis of some frequently prescribed selective serotonin re-uptake inhibitors (SSRI)-venlafaxine, fluvoxamine, mirtazapine, fluoxetine, citalopram, and sertraline-in urine samples. The SPME-based method enables simultaneous determination of the target SSRI after simple in-situ derivatization of some of the target compounds. Calibration curves in water and in urine were validated and statistically compared. This revealed the absence of matrix effect and, in consequence, the possibility of quantifying SSRI in urine samples by external water calibration. Intra-day and inter-day precision was satisfactory for all the target compounds (relative standard deviation, RSD, <14%) and the detection limits achieved were <0.4 ng mL(-1) urine. The time required for the SPME step and for GC analysis (30 min each) enables high throughput. The method was applied to real urine samples from different patients being treated with some of these pharmaceuticals. Some SSRI metabolites were also detected and tentatively identified.

  16. Surveying Mercury Levels in Hair, Blood and Urine of under 7-Year Old Children from a Coastal City in China

    PubMed Central

    Chen, Guixia; Chen, Xiaoxin; Yan, Chonghuai; Wu, Xingdong; Zeng, Guozhang

    2014-01-01

    Aim: The average mercury load in children under 7-years old was determined in a populated but not overly industrial coastal area in China. Methods: 395 blood samples, 1072 urine samples, and 581 hair samples were collected from 1076 children, aged 0 to 6 years, from eight representative communities of Xiamen, China. Mercury levels in the samples were surveyed. Results: The 95% upper limits of mercury in blood, urine, and hair for the children were 2.30, 1.50 and 2100.00 μg/kg, respectively. Levels tended to increase with age. Correlation analyses showed that mercury levels in blood and urine correlated with those in hair (n = 132), r = 0.49, p < 0.0001 and r = 0.20, p = 0.0008; however, blood mercury levels did not correlate with urine levels (n = 284), r = 0.07, p = 0.35. Conclusions: Surveying the average mercury load in children 0 to 6 years, and the 95% upper limit value of mercury in their blood, urine, and hair should help guide risk assessment and health management for children. PMID:25419876

  17. Major Odorants Released as Urinary Volatiles by Urinary Incontinent Patients

    PubMed Central

    Pandey, Sudhir Kumar; Kim, Ki-Hyun; Choi, Si On; Sa, In Young; Oh, Soo Yeon

    2013-01-01

    In this study, volatile urinary components were collected using three different types of samples from patients suffering from urinary incontinence (UI): (1) urine (A); (2) urine + non-used pad (B); and (3) urine + used pad (C). In addition, urine + non-used pad (D) samples from non-patients were also collected as a reference. The collection of urinary volatiles was conducted with the aid of a glass impinger-based mini-chamber method. Each of the four sample types (A through D) was placed in a glass impinger and incubated for 4 hours at 37 °C. Ultra pure air was then passed through the chamber, and volatile urine gas components were collected into Tedlar bags at the other end. These bag samples were then analyzed for a wide range of VOCs and major offensive odorants (e.g., reduced sulfur compounds (RSCs), carbonyls, trimethylamine (TMA), ammonia, etc.). Among the various odorants, sulfur compounds (methanethiol and hydrogen sulfide) and aldehydes (acetaldehyde, butylaldehyde, and isovaleraldehyde) were detected above odor threshold and predicted to contribute most effectively to odor intensity of urine incontinence. PMID:23823973

  18. [Sampling, storage and transport of biological materials collected from living and deceased subjects for determination of concentration levels of ethyl alcohol and similarly acting substances. A proposal of updating the blood and urine sampling protocol].

    PubMed

    Wiergowski, Marek; Reguła, Krystyna; Pieśniak, Dorota; Galer-Tatarowicz, Katarzyna; Szpiech, Beata; Jankowski, Zbigniew

    2007-01-01

    The present paper emphasizes the most common mistakes committed at the beginning of an analytical procedure. To shorten the time and decrease the cost of determinations of substances with similar to alcohol activity, it is postulated to introduce mass-scale screening analysis of saliva collected from a living subject at the site of the event, with all positive results confirmed in blood or urine samples. If no saliva sample is collected for toxicology, a urine sample, allowing for a stat fast screening analysis, and a blood sample, to confirm the result, should be ensured. Inappropriate storage of a blood sample in the tube without a preservative can cause sample spilling and its irretrievable loss. The authors propose updating the "Blood/urine sampling protocol", with the updated version to be introduced into practice following consultations and revisions.

  19. ECLSS Sustaining Compatibility Testing on Urine Processor Assembly Nonmetallic Materials for Reformulation of Pretreated Urine Solution

    NASA Technical Reports Server (NTRS)

    Wingard, C. D.

    2015-01-01

    On International Space Station (ISS), the Urine Processor Assembly (UPA) converts human urine and flush water into potable water. The urine is acid-pretreated primarily to control microbial growth. In recent years, the sulfuric acid (H2SO4) pretreatment was believed to be largely responsible for producing salt crystals capable of plugging filters in UPA components and significantly reducing the percentage of water recovery from urine. In 2012, ISS management decided to change the acid pretreatment for urine from sulfuric to phosphoric with the goal of eliminating or minimizing formation of salt crystals. In 2013-2014, as part of the qualification of the phosphoric acid (H3PO4) formulation, samples of 12 nonmetallic materials used in UPA components were immersed for up to one year in pretreated urine and brine solutions made with the new H3PO4 formulation. Dynamic mechanical analysis (DMA) was used to measure modulus (stiffness) of the immersed samples compared to virgin control samples. Such compatibility data obtained by DMA for the H3PO4-based solutions were compared to DMA data obtained for the H2SO4-based solutions in 2002-2003.

  20. Flow meter urine testing: a practical proposition in patients attending for urodynamics?

    PubMed

    Hashim, Hashim; Abrams, Paul

    2006-05-01

    To find a practical way of detecting urinary tract infection (UTI) before invasive urodynamic testing, as UTIs after urodynamics are well documented, but there are no standard guidelines about when urine should be analysed before urodynamics. Before urodynamics all patients are asked to provide a free urine flow; the patient is then catheterized to obtain a catheter-specimen of urine that is tested for infection by a urine dipstick. If the dipstick is found positive for nitrites and/or leukocytes, the test is abandoned and the sample sent for microscopy, culture and sensitivity. In the present study, patients were asked to provide a free urine flow into the flowmeter as usual. Between patients, the flowmeter was washed with soap and water and dried, so that there would be no cross-contamination between patients' urine results. Urine was collected as usual and tested using a dipstick, the patient was then catheterized and another dipstick test done on the catheter specimen of urine (CSU), to compare results. Pairs of urine samples, when positive for nitrite were 100% consistent, and 89% of pairs positive for leukocytes were the same before and after catheterization. The remaining 11% (all women) of the positive leukocyte group had leukocytosis on testing the flowmeter urine but not on the CSU, possibly due to contamination from the vagina. Testing urine by dipstick in the sample from the flowmeter is a feasible option, thus saving the patient an inappropriate catheterization, with the risk of bacteraemia during urodynamics, and allowing the flowrate to be measured.

Top