Partial volume correction and image analysis methods for intersubject comparison of FDG-PET studies
NASA Astrophysics Data System (ADS)
Yang, Jun
2000-12-01
Partial volume effect is an artifact mainly due to the limited imaging sensor resolution. It creates bias in the measured activity in small structures and around tissue boundaries. In brain FDG-PET studies, especially for Alzheimer's disease study where there is serious gray matter atrophy, accurate estimate of cerebral metabolic rate of glucose is even more problematic due to large amount of partial volume effect. In this dissertation, we developed a framework enabling inter-subject comparison of partial volume corrected brain FDG-PET studies. The framework is composed of the following image processing steps: (1)MRI segmentation, (2)MR-PET registration, (3)MR based PVE correction, (4)MR 3D inter-subject elastic mapping. Through simulation studies, we showed that the newly developed partial volume correction methods, either pixel based or ROI based, performed better than previous methods. By applying this framework to a real Alzheimer's disease study, we demonstrated that the partial volume corrected glucose rates vary significantly among the control, at risk and disease patient groups and this framework is a promising tool useful for assisting early identification of Alzheimer's patients.
Park, Kyungnam; Lee, Jangyoung; Kim, Soo-Young; Kim, Jinwoo; Kim, Insoo; Choi, Seung Pill; Jeong, Sikyung; Hong, Sungyoup
2013-06-01
This study assessed the method of fluid infusion control using an IntraVenous Infusion Controller (IVIC). Four methods of infusion control (dial flow controller, IV set without correction, IV set with correction and IVIC correction) were used to measure the volume of each technique at two infusion rates. The infused fluid volume with a dial flow controller was significantly larger than other methods. The infused fluid volume was significantly smaller with an IV set without correction over time. Regarding the concordance correlation coefficient (CCC) of infused fluid volume in relation to a target volume, IVIC correction was shown to have the highest level of agreement. The flow rate measured in check mode showed a good agreement with the volume of collected fluid after passing through the IV system. Thus, an IVIC could assist in providing an accurate infusion control. © 2013 Wiley Publishing Asia Pty Ltd.
The Accuracy and Precision of Flow Measurements Using Phase Contrast Techniques
NASA Astrophysics Data System (ADS)
Tang, Chao
Quantitative volume flow rate measurements using the magnetic resonance imaging technique are studied in this dissertation because the volume flow rates have a special interest in the blood supply of the human body. The method of quantitative volume flow rate measurements is based on the phase contrast technique, which assumes a linear relationship between the phase and flow velocity of spins. By measuring the phase shift of nuclear spins and integrating velocity across the lumen of the vessel, we can determine the volume flow rate. The accuracy and precision of volume flow rate measurements obtained using the phase contrast technique are studied by computer simulations and experiments. The various factors studied include (1) the partial volume effect due to voxel dimensions and slice thickness relative to the vessel dimensions; (2) vessel angulation relative to the imaging plane; (3) intravoxel phase dispersion; (4) flow velocity relative to the magnitude of the flow encoding gradient. The partial volume effect is demonstrated to be the major obstacle to obtaining accurate flow measurements for both laminar and plug flow. Laminar flow can be measured more accurately than plug flow in the same condition. Both the experiment and simulation results for laminar flow show that, to obtain the accuracy of volume flow rate measurements to within 10%, at least 16 voxels are needed to cover the vessel lumen. The accuracy of flow measurements depends strongly on the relative intensity of signal from stationary tissues. A correction method is proposed to compensate for the partial volume effect. The correction method is based on a small phase shift approximation. After the correction, the errors due to the partial volume effect are compensated, allowing more accurate results to be obtained. An automatic program based on the correction method is developed and implemented on a Sun workstation. The correction method is applied to the simulation and experiment results. The results show that the correction significantly reduces the errors due to the partial volume effect. We apply the correction method to the data of in vivo studies. Because the blood flow is not known, the results of correction are tested according to the common knowledge (such as cardiac output) and conservation of flow. For example, the volume of blood flowing to the brain should be equal to the volume of blood flowing from the brain. Our measurement results are very convincing.
Influence of signal intensity non-uniformity on brain volumetry using an atlas-based method.
Goto, Masami; Abe, Osamu; Miyati, Tosiaki; Kabasawa, Hiroyuki; Takao, Hidemasa; Hayashi, Naoto; Kurosu, Tomomi; Iwatsubo, Takeshi; Yamashita, Fumio; Matsuda, Hiroshi; Mori, Harushi; Kunimatsu, Akira; Aoki, Shigeki; Ino, Kenji; Yano, Keiichi; Ohtomo, Kuni
2012-01-01
Many studies have reported pre-processing effects for brain volumetry; however, no study has investigated whether non-parametric non-uniform intensity normalization (N3) correction processing results in reduced system dependency when using an atlas-based method. To address this shortcoming, the present study assessed whether N3 correction processing provides reduced system dependency in atlas-based volumetry. Contiguous sagittal T1-weighted images of the brain were obtained from 21 healthy participants, by using five magnetic resonance protocols. After image preprocessing using the Statistical Parametric Mapping 5 software, we measured the structural volume of the segmented images with the WFU-PickAtlas software. We applied six different bias-correction levels (Regularization 10, Regularization 0.0001, Regularization 0, Regularization 10 with N3, Regularization 0.0001 with N3, and Regularization 0 with N3) to each set of images. The structural volume change ratio (%) was defined as the change ratio (%) = (100 × [measured volume - mean volume of five magnetic resonance protocols] / mean volume of five magnetic resonance protocols) for each bias-correction level. A low change ratio was synonymous with lower system dependency. The results showed that the images with the N3 correction had a lower change ratio compared with those without the N3 correction. The present study is the first atlas-based volumetry study to show that the precision of atlas-based volumetry improves when using N3-corrected images. Therefore, correction for signal intensity non-uniformity is strongly advised for multi-scanner or multi-site imaging trials.
Influence of Signal Intensity Non-Uniformity on Brain Volumetry Using an Atlas-Based Method
Abe, Osamu; Miyati, Tosiaki; Kabasawa, Hiroyuki; Takao, Hidemasa; Hayashi, Naoto; Kurosu, Tomomi; Iwatsubo, Takeshi; Yamashita, Fumio; Matsuda, Hiroshi; Mori, Harushi; Kunimatsu, Akira; Aoki, Shigeki; Ino, Kenji; Yano, Keiichi; Ohtomo, Kuni
2012-01-01
Objective Many studies have reported pre-processing effects for brain volumetry; however, no study has investigated whether non-parametric non-uniform intensity normalization (N3) correction processing results in reduced system dependency when using an atlas-based method. To address this shortcoming, the present study assessed whether N3 correction processing provides reduced system dependency in atlas-based volumetry. Materials and Methods Contiguous sagittal T1-weighted images of the brain were obtained from 21 healthy participants, by using five magnetic resonance protocols. After image preprocessing using the Statistical Parametric Mapping 5 software, we measured the structural volume of the segmented images with the WFU-PickAtlas software. We applied six different bias-correction levels (Regularization 10, Regularization 0.0001, Regularization 0, Regularization 10 with N3, Regularization 0.0001 with N3, and Regularization 0 with N3) to each set of images. The structural volume change ratio (%) was defined as the change ratio (%) = (100 × [measured volume - mean volume of five magnetic resonance protocols] / mean volume of five magnetic resonance protocols) for each bias-correction level. Results A low change ratio was synonymous with lower system dependency. The results showed that the images with the N3 correction had a lower change ratio compared with those without the N3 correction. Conclusion The present study is the first atlas-based volumetry study to show that the precision of atlas-based volumetry improves when using N3-corrected images. Therefore, correction for signal intensity non-uniformity is strongly advised for multi-scanner or multi-site imaging trials. PMID:22778560
Effects of Regularisation Priors and Anatomical Partial Volume Correction on Dynamic PET Data
NASA Astrophysics Data System (ADS)
Caldeira, Liliana L.; Silva, Nuno da; Scheins, Jürgen J.; Gaens, Michaela E.; Shah, N. Jon
2015-08-01
Dynamic PET provides temporal information about the tracer uptake. However, each PET frame has usually low statistics, resulting in noisy images. Furthermore, PET images suffer from partial volume effects. The goal of this study is to understand the effects of prior regularisation on dynamic PET data and subsequent anatomical partial volume correction. The Median Root Prior (MRP) regularisation method was used in this work during reconstruction. The quantification and noise in image-domain and time-domain (time-activity curves) as well as the impact on parametric images is assessed and compared with Ordinary Poisson Ordered Subset Expectation Maximisation (OP-OSEM) reconstruction with and without Gaussian filter. This study shows the improvement in PET images and time-activity curves (TAC) in terms of noise as well as in the parametric images when using prior regularisation in dynamic PET data. Anatomical partial volume correction improves the TAC and consequently, parametric images. Therefore, the use of MRP with anatomical partial volume correction is of interest for dynamic PET studies.
Optimization-based mesh correction with volume and convexity constraints
D'Elia, Marta; Ridzal, Denis; Peterson, Kara J.; ...
2016-02-24
In this study, we consider the problem of finding a mesh such that 1) it is the closest, with respect to a suitable metric, to a given source mesh having the same connectivity, and 2) the volumes of its cells match a set of prescribed positive values that are not necessarily equal to the cell volumes in the source mesh. This volume correction problem arises in important simulation contexts, such as satisfying a discrete geometric conservation law and solving transport equations by incremental remapping or similar semi-Lagrangian transport schemes. In this paper we formulate volume correction as a constrained optimizationmore » problem in which the distance to the source mesh defines an optimization objective, while the prescribed cell volumes, mesh validity and/or cell convexity specify the constraints. We solve this problem numerically using a sequential quadratic programming (SQP) method whose performance scales with the mesh size. To achieve scalable performance we develop a specialized multigrid-based preconditioner for optimality systems that arise in the application of the SQP method to the volume correction problem. Numerical examples illustrate the importance of volume correction, and showcase the accuracy, robustness and scalability of our approach.« less
Jensen, Jonas; Olesen, Jacob Bjerring; Stuart, Matthias Bo; Hansen, Peter Møller; Nielsen, Michael Bachmann; Jensen, Jørgen Arendt
2016-08-01
A method for vector velocity volume flow estimation is presented, along with an investigation of its sources of error and correction of actual volume flow measurements. Volume flow errors are quantified theoretically by numerical modeling, through flow phantom measurements, and studied in vivo. This paper investigates errors from estimating volumetric flow using a commercial ultrasound scanner and the common assumptions made in the literature. The theoretical model shows, e.g. that volume flow is underestimated by 15%, when the scan plane is off-axis with the vessel center by 28% of the vessel radius. The error sources were also studied in vivo under realistic clinical conditions, and the theoretical results were applied for correcting the volume flow errors. Twenty dialysis patients with arteriovenous fistulas were scanned to obtain vector flow maps of fistulas. When fitting an ellipsis to cross-sectional scans of the fistulas, the major axis was on average 10.2mm, which is 8.6% larger than the minor axis. The ultrasound beam was on average 1.5mm from the vessel center, corresponding to 28% of the semi-major axis in an average fistula. Estimating volume flow with an elliptical, rather than circular, vessel area and correcting the ultrasound beam for being off-axis, gave a significant (p=0.008) reduction in error from 31.2% to 24.3%. The error is relative to the Ultrasound Dilution Technique, which is considered the gold standard for volume flow estimation for dialysis patients. The study shows the importance of correcting for volume flow errors, which are often made in clinical practice. Copyright © 2016 Elsevier B.V. All rights reserved.
Gambarota, Giulio; Hitti, Eric; Leporq, Benjamin; Saint-Jalmes, Hervé; Beuf, Olivier
2017-01-01
Tissue perfusion measurements using intravoxel incoherent motion (IVIM) diffusion-MRI are of interest for investigations of liver pathologies. A confounding factor in the perfusion quantification is the partial volume between liver tissue and large blood vessels. The aim of this study was to assess and correct for this partial volume effect in the estimation of the perfusion fraction. MRI experiments were performed at 3 Tesla with a diffusion-MRI sequence at 12 b-values. Diffusion signal decays in liver were analyzed using the non-negative least square (NNLS) method and the biexponential fitting approach. In some voxels, the NNLS analysis yielded a very fast-decaying component that was assigned to partial volume with the blood flowing in large vessels. Partial volume correction was performed by biexponential curve fitting, where the first data point (b = 0 s/mm 2 ) was eliminated in voxels with a very fast-decaying component. Biexponential fitting with partial volume correction yielded parametric maps with perfusion fraction values smaller than biexponential fitting without partial volume correction. The results of the current study indicate that the NNLS analysis in combination with biexponential curve fitting allows to correct for partial volume effects originating from blood flow in IVIM perfusion fraction measurements. Magn Reson Med 77:310-317, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
The influence of kyphosis correction surgery on pulmonary function and thoracic volume.
Zeng, Yan; Chen, Zhongqiang; Ma, Desi; Guo, Zhaoqing; Qi, Qiang; Li, Weishi; Sun, Chuiguo; Liu, Ning; White, Andrew P
2014-10-01
A clinical study. To measure the changes in pulmonary function and thoracic volume associated with surgical correction of kyphotic deformities. No prior study has focused on the pulmonary function and thoracic cavity volume before and after corrective surgery for kyphosis. Thirty-four patients with kyphosis underwent posterior deformity correction with instrumented fusion. Preoperative and postoperative pulmonary function was measured, and pulmonary function grade was evaluated as mild, significant, or severe. The change in preoperative to postoperative pulmonary function was analyzed, using 6 comparative subgroupings of patients on the basis of age, severity of kyphosis, location of kyphosis apex, length of follow-up time after surgery, degree of kyphosis correction, and number of segments fused. A second group of 19 patients also underwent posterior surgical correction of kyphosis, which had thoracic volume measured preoperatively and postoperatively with computed tomographic scanning. All of the pulmonary impairments were found to be restrictive. After surgery, most of the patients had improvement of the pulmonary function. Before surgery, the pulmonary function differences were found to be significant based on both severity of preoperative kyphosis (<60° vs. >60°) and location of the kyphosis apex (above T10 vs. below T10). Younger patients (younger than 35 yr) were more likely to exhibit statistically significant improvements in pulmonary function after surgery. However, thoracic volume was not significantly related to pulmonary function parameters. After surgery, average thoracic volume had no significant change. The major pulmonary impairment caused by kyphosis was found to be restrictive. Patients with kyphosis angle of 60° or greater or with kyphosis apex above T10 had more severe pulmonary dysfunction. Patients' age was significantly related to change in pulmonary function after surgery. However, the average thoracic volume had no significant change after surgery. 3.
Mikkelsen, Mark; Singh, Krish D; Brealy, Jennifer A; Linden, David E J; Evans, C John
2016-11-01
The quantification of γ-aminobutyric acid (GABA) concentration using localised MRS suffers from partial volume effects related to differences in the intrinsic concentration of GABA in grey (GM) and white (WM) matter. These differences can be represented as a ratio between intrinsic GABA in GM and WM: r M . Individual differences in GM tissue volume can therefore potentially drive apparent concentration differences. Here, a quantification method that corrects for these effects is formulated and empirically validated. Quantification using tissue water as an internal concentration reference has been described previously. Partial volume effects attributed to r M can be accounted for by incorporating into this established method an additional multiplicative correction factor based on measured or literature values of r M weighted by the proportion of GM and WM within tissue-segmented MRS volumes. Simulations were performed to test the sensitivity of this correction using different assumptions of r M taken from previous studies. The tissue correction method was then validated by applying it to an independent dataset of in vivo GABA measurements using an empirically measured value of r M . It was shown that incorrect assumptions of r M can lead to overcorrection and inflation of GABA concentration measurements quantified in volumes composed predominantly of WM. For the independent dataset, GABA concentration was linearly related to GM tissue volume when only the water signal was corrected for partial volume effects. Performing a full correction that additionally accounts for partial volume effects ascribed to r M successfully removed this dependence. With an appropriate assumption of the ratio of intrinsic GABA concentration in GM and WM, GABA measurements can be corrected for partial volume effects, potentially leading to a reduction in between-participant variance, increased power in statistical tests and better discriminability of true effects. Copyright © 2016 John Wiley & Sons, Ltd.
Alzheimer's disease detection using 11C-PiB with improved partial volume effect correction
NASA Astrophysics Data System (ADS)
Raniga, Parnesh; Bourgeat, Pierrick; Fripp, Jurgen; Acosta, Oscar; Ourselin, Sebastien; Rowe, Christopher; Villemagne, Victor L.; Salvado, Olivier
2009-02-01
Despite the increasing use of 11C-PiB in research into Alzheimer's disease (AD), there are few standardized analysis procedures that have been reported or published. This is especially true with regards to partial volume effects (PVE) and partial volume correction. Due to the nature of PET physics and acquisition, PET images exhibit relatively low spatial resolution compared to other modalities, resulting in bias of quantitative results. Although previous studies have applied PVE correction techniques on 11C-PiB data, the results have not been quantitatively evaluated and compared against uncorrected data. The aim of this study is threefold. Firstly, a realistic synthetic phantom was created to quantify PVE. Secondly, MRI partial volume estimate segmentations were used to improve voxel-based PVE correction instead of using hard segmentations. Thirdly, quantification of PVE correction was evaluated on 34 subjects (AD=10, Normal Controls (NC)=24), including 12 PiB positive NC. Regional analysis was performed using the Anatomical Automatic Labeling (AAL) template, which was registered to each patient. Regions of interest were restricted to the gray matter (GM) defined by the MR segmentation. Average normalized intensity of the neocortex and selected regions were used to evaluate the discrimination power between AD and NC both with and without PVE correction. Receiver Operating Characteristic (ROC) curves were computed for the binary discrimination task. The phantom study revealed signal losses due to PVE between 10 to 40 % which were mostly recovered to within 5% after correction. Better classification was achieved after PVE correction, resulting in higher areas under ROC curves.
Optimization of yttrium-90 PET for simultaneous PET/MR imaging: A phantom study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eldib, Mootaz
2016-08-15
Purpose: Positron emission tomography (PET) imaging of yttrium-90 in the liver post radioembolization has been shown useful for personalized dosimetry calculations and evaluation of extrahepatic deposition. The purpose of this study was to quantify the benefits of several MR-based data correction approaches offered by using a combined PET/MR system to improve Y-90 PET imaging. In particular, the feasibility of motion and partial volume corrections were investigated in a controlled phantom study. Methods: The ACR phantom was filled with an initial concentration of 8 GBq of Y-90 solution resulting in a contrast of 10:1 between the hot cylinders and the background.more » Y-90 PET motion correction through motion estimates from MR navigators was evaluated by using a custom-built motion stage that simulated realistic amplitudes of respiration-induced liver motion. Finally, the feasibility of an MR-based partial volume correction method was evaluated using a wavelet decomposition approach. Results: Motion resulted in a large (∼40%) loss of contrast recovery for the 8 mm cylinder in the phantom, but was corrected for after MR-based motion correction was applied. Partial volume correction improved contrast recovery by 13% for the 8 mm cylinder. Conclusions: MR-based data correction improves Y-90 PET imaging on simultaneous PET/MR systems. Assessment of these methods must be studied further in the clinical setting.« less
Azangwe, Godfrey; Grochowska, Paulina; Georg, Dietmar; Izewska, Joanna; Hopfgartner, Johannes; Lechner, Wolfgang; Andersen, Claus E; Beierholm, Anders R; Helt-Hansen, Jakob; Mizuno, Hideyuki; Fukumura, Akifumi; Yajima, Kaori; Gouldstone, Clare; Sharpe, Peter; Meghzifene, Ahmed; Palmans, Hugo
2014-07-01
The aim of the present study is to provide a comprehensive set of detector specific correction factors for beam output measurements for small beams, for a wide range of real time and passive detectors. The detector specific correction factors determined in this study may be potentially useful as a reference data set for small beam dosimetry measurements. Dose response of passive and real time detectors was investigated for small field sizes shaped with a micromultileaf collimator ranging from 0.6 × 0.6 cm(2) to 4.2 × 4.2 cm(2) and the measurements were extended to larger fields of up to 10 × 10 cm(2). Measurements were performed at 5 cm depth, in a 6 MV photon beam. Detectors used included alanine, thermoluminescent dosimeters (TLDs), stereotactic diode, electron diode, photon diode, radiophotoluminescent dosimeters (RPLDs), radioluminescence detector based on carbon-doped aluminium oxide (Al2O3:C), organic plastic scintillators, diamond detectors, liquid filled ion chamber, and a range of small volume air filled ionization chambers (volumes ranging from 0.002 cm(3) to 0.3 cm(3)). All detector measurements were corrected for volume averaging effect and compared with dose ratios determined from alanine to derive a detector correction factors that account for beam perturbation related to nonwater equivalence of the detector materials. For the detectors used in this study, volume averaging corrections ranged from unity for the smallest detectors such as the diodes, 1.148 for the 0.14 cm(3) air filled ionization chamber and were as high as 1.924 for the 0.3 cm(3) ionization chamber. After applying volume averaging corrections, the detector readings were consistent among themselves and with alanine measurements for several small detectors but they differed for larger detectors, in particular for some small ionization chambers with volumes larger than 0.1 cm(3). The results demonstrate how important it is for the appropriate corrections to be applied to give consistent and accurate measurements for a range of detectors in small beam geometry. The results further demonstrate that depending on the choice of detectors, there is a potential for large errors when effects such as volume averaging, perturbation and differences in material properties of detectors are not taken into account. As the commissioning of small fields for clinical treatment has to rely on accurate dose measurements, the authors recommend the use of detectors that require relatively little correction, such as unshielded diodes, diamond detectors or microchambers, and solid state detectors such as alanine, TLD, Al2O3:C, or scintillators.
Marcos, Raül; Llasat, Ma Carmen; Quintana-Seguí, Pere; Turco, Marco
2018-01-01
In this paper, we have compared different bias correction methodologies to assess whether they could be advantageous for improving the performance of a seasonal prediction model for volume anomalies in the Boadella reservoir (northwestern Mediterranean). The bias correction adjustments have been applied on precipitation and temperature from the European Centre for Middle-range Weather Forecasting System 4 (S4). We have used three bias correction strategies: two linear (mean bias correction, BC, and linear regression, LR) and one non-linear (Model Output Statistics analogs, MOS-analog). The results have been compared with climatology and persistence. The volume-anomaly model is a previously computed Multiple Linear Regression that ingests precipitation, temperature and in-flow anomaly data to simulate monthly volume anomalies. The potential utility for end-users has been assessed using economic value curve areas. We have studied the S4 hindcast period 1981-2010 for each month of the year and up to seven months ahead considering an ensemble of 15 members. We have shown that the MOS-analog and LR bias corrections can improve the original S4. The application to volume anomalies points towards the possibility to introduce bias correction methods as a tool to improve water resource seasonal forecasts in an end-user context of climate services. Particularly, the MOS-analog approach gives generally better results than the other approaches in late autumn and early winter. Copyright © 2017 Elsevier B.V. All rights reserved.
SU-E-T-762: Toward Volume-Based Independent Dose Verification as Secondary Check
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tachibana, H; Tachibana, R
2015-06-15
Purpose: Lung SBRT plan has been shifted to volume prescription technique. However, point dose agreement is still verified using independent dose verification at the secondary check. The volume dose verification is more affected by inhomogeneous correction rather than point dose verification currently used as the check. A feasibility study for volume dose verification was conducted in lung SBRT plan. Methods: Six SBRT plans were collected in our institute. Two dose distributions with / without inhomogeneous correction were generated using Adaptive Convolve (AC) in Pinnacle3. Simple MU Analysis (SMU, Triangle Product, Ishikawa, JP) was used as the independent dose verification softwaremore » program, in which a modified Clarkson-based algorithm was implemented and radiological path length was computed using CT images independently to the treatment planning system. The agreement in point dose and mean dose between the AC with / without the correction and the SMU were assessed. Results: In the point dose evaluation for the center of the GTV, the difference shows the systematic shift (4.5% ± 1.9 %) in comparison of the AC with the inhomogeneous correction, on the other hands, there was good agreement of 0.2 ± 0.9% between the SMU and the AC without the correction. In the volume evaluation, there were significant differences in mean dose for not only PTV (14.2 ± 5.1 %) but also GTV (8.0 ± 5.1 %) compared to the AC with the correction. Without the correction, the SMU showed good agreement for GTV (1.5 ± 0.9%) as well as PTV (0.9% ± 1.0%). Conclusion: The volume evaluation for secondary check may be possible in homogenous region. However, the volume including the inhomogeneous media would make larger discrepancy. Dose calculation algorithm for independent verification needs to be modified to take into account the inhomogeneous correction.« less
Terlier, T; Lee, J; Lee, K; Lee, Y
2018-02-06
Technological progress has spurred the development of increasingly sophisticated analytical devices. The full characterization of structures in terms of sample volume and composition is now highly complex. Here, a highly improved solution for 3D characterization of samples, based on an advanced method for 3D data correction, is proposed. Traditionally, secondary ion mass spectrometry (SIMS) provides the chemical distribution of sample surfaces. Combining successive sputtering with 2D surface projections enables a 3D volume rendering to be generated. However, surface topography can distort the volume rendering by necessitating the projection of a nonflat surface onto a planar image. Moreover, the sputtering is highly dependent on the probed material. Local variation of composition affects the sputter yield and the beam-induced roughness, which in turn alters the 3D render. To circumvent these drawbacks, the correlation of atomic force microscopy (AFM) with SIMS has been proposed in previous studies as a solution for the 3D chemical characterization. To extend the applicability of this approach, we have developed a methodology using AFM-time-of-flight (ToF)-SIMS combined with an empirical sputter model, "dynamic-model-based volume correction", to universally correct 3D structures. First, the simulation of 3D structures highlighted the great advantages of this new approach compared with classical methods. Then, we explored the applicability of this new correction to two types of samples, a patterned metallic multilayer and a diblock copolymer film presenting surface asperities. In both cases, the dynamic-model-based volume correction produced an accurate 3D reconstruction of the sample volume and composition. The combination of AFM-SIMS with the dynamic-model-based volume correction improves the understanding of the surface characteristics. Beyond the useful 3D chemical information provided by dynamic-model-based volume correction, the approach permits us to enhance the correlation of chemical information from spectroscopic techniques with the physical properties obtained by AFM.
The power-proportion method for intracranial volume correction in volumetric imaging analysis.
Liu, Dawei; Johnson, Hans J; Long, Jeffrey D; Magnotta, Vincent A; Paulsen, Jane S
2014-01-01
In volumetric brain imaging analysis, volumes of brain structures are typically assumed to be proportional or linearly related to intracranial volume (ICV). However, evidence abounds that many brain structures have power law relationships with ICV. To take this relationship into account in volumetric imaging analysis, we propose a power law based method-the power-proportion method-for ICV correction. The performance of the new method is demonstrated using data from the PREDICT-HD study.
Zhang, You; Ma, Jianhua; Iyengar, Puneeth; Zhong, Yuncheng; Wang, Jing
2017-01-01
Purpose Sequential same-patient CT images may involve deformation-induced and non-deformation-induced voxel intensity changes. An adaptive deformation recovery and intensity correction (ADRIC) technique was developed to improve the CT reconstruction accuracy, and to separate deformation from non-deformation-induced voxel intensity changes between sequential CT images. Materials and Methods ADRIC views the new CT volume as a deformation of a prior high-quality CT volume, but with additional non-deformation-induced voxel intensity changes. ADRIC first applies the 2D-3D deformation technique to recover the deformation field between the prior CT volume and the new, to-be-reconstructed CT volume. Using the deformation-recovered new CT volume, ADRIC further corrects the non-deformation-induced voxel intensity changes with an updated algebraic reconstruction technique (‘ART-dTV’). The resulting intensity-corrected new CT volume is subsequently fed back into the 2D-3D deformation process to further correct the residual deformation errors, which forms an iterative loop. By ADRIC, the deformation field and the non-deformation voxel intensity corrections are optimized separately and alternately to reconstruct the final CT. CT myocardial perfusion imaging scenarios were employed to evaluate the efficacy of ADRIC, using both simulated data of the extended-cardiac-torso (XCAT) digital phantom and experimentally acquired porcine data. The reconstruction accuracy of the ADRIC technique was compared to the technique using ART-dTV alone, and to the technique using 2D-3D deformation alone. The relative error metric and the universal quality index metric are calculated between the images for quantitative analysis. The relative error is defined as the square root of the sum of squared voxel intensity differences between the reconstructed volume and the ‘ground-truth’ volume, normalized by the square root of the sum of squared ‘ground-truth’ voxel intensities. In addition to the XCAT and porcine studies, a physical lung phantom measurement study was also conducted. Water-filled balloons with various shapes/volumes and concentrations of iodinated contrasts were put inside the phantom to simulate both deformations and non-deformation-induced intensity changes for ADRIC reconstruction. The ADRIC-solved deformations and intensity changes from limited-view projections were compared to those of the ‘gold-standard’ volumes reconstructed from fully-sampled projections. Results For the XCAT simulation study, the relative errors of the reconstructed CT volume by the 2D-3D deformation technique, the ART-dTV technique and the ADRIC technique were 14.64%, 19.21% and 11.90% respectively, by using 20 projections for reconstruction. Using 60 projections for reconstruction reduced the relative errors to 12.33%, 11.04% and 7.92% for the three techniques, respectively. For the porcine study, the corresponding results were 13.61%, 8.78%, 6.80% by using 20 projections; and 12.14%, 6.91% and 5.29% by using 60 projections. The ADRIC technique also demonstrated robustness to varying projection exposure levels. For the physical phantom study, the average DICE coefficient between the initial prior balloon volume and the new ‘gold-standard’ balloon volumes was 0.460. ADRIC reconstruction by 21 projections increased the average DICE coefficient to 0.954. Conclusion The ADRIC technique outperformed both the 2D-3D deformation technique and the ART-dTV technique in reconstruction accuracy. The alternately solved deformation field and non-deformation voxel intensity corrections can benefit multiple clinical applications, including tumor tracking, radiotherapy dose accumulation and treatment outcome analysis. PMID:28380247
ERIC Educational Resources Information Center
Vogel, Ronald J.
A study was conducted in 1976 of applicants who submitted corrections or amendments to their Student Eligibility Reports (SERs) for the Basic Educational Opportunity Grant (BEOG) Program. The objective was to review the applications corrections process and to determine factors linked to applicants' use of correction procedures. Attention was…
Monitoring of intracranial compliance: correction for a change in body position.
Raabe, A; Czosnyka, M; Piper, I; Seifert, V
1999-01-01
The objectives of our study were 1. to investigate whether the intracranial compliance changes with body position; 2. to test if the pressure-volume index (PVI) calculation is affected by different body positions; 3. to define the optimal parameter to correct PVI for changes in body position and 4. to investigate the physiological meaning of the constant term (P0) in the model of the intracranial volume-pressure relationship. Thirteen patients were included in this study. All patients were subjected to 2 to 3 different body positions. In each position, either classic bolus injection was performed for measurement of intracranial compliance and calculation of PVI or the new Spiegelberg compliance monitor was used to calculate PVI continuously. Four different models were used for calculating the constant pressure term P0 and the P0 corrected PVI values. Pressure volume index not corrected for the constant term P0 significantly decreased with elevating the patients head (r = 0.70, p < 0.0001). In contrast, volume-pressure response and ICP pulse amplitude did not change with position. Using the constant term P0 to correct the PVI we found no changes between the different body positions. Our results suggest that during the variation in body position there is no change in intracranial compliance but a change in hydrostatic offset pressure which causes a shifting of the volume-pressure curve along the pressure axis without its shape being affected. PVI measurements should either be performed only with the patient in the 0 degree recumbent position or that the PVI calculation should be corrected for the hydrostatic difference between the level of the ICP transducer and the hydrostatic indifference point of the craniospinal system close to the third thoracic vertebra.
Hautvast, Gilion L T F; Salton, Carol J; Chuang, Michael L; Breeuwer, Marcel; O'Donnell, Christopher J; Manning, Warren J
2012-05-01
Quantitative analysis of short-axis functional cardiac magnetic resonance images can be performed using automatic contour detection methods. The resulting myocardial contours must be reviewed and possibly corrected, which can be time-consuming, particularly when performed across all cardiac phases. We quantified the impact of manual contour corrections on both analysis time and quantitative measurements obtained from left ventricular short-axis cine images acquired from 1555 participants of the Framingham Heart Study Offspring cohort using computer-aided contour detection methods. The total analysis time for a single case was 7.6 ± 1.7 min for an average of 221 ± 36 myocardial contours per participant. This included 4.8 ± 1.6 min for manual contour correction of 2% of all automatically detected endocardial contours and 8% of all automatically detected epicardial contours. However, the impact of these corrections on global left ventricular parameters was limited, introducing differences of 0.4 ± 4.1 mL for end-diastolic volume, -0.3 ± 2.9 mL for end-systolic volume, 0.7 ± 3.1 mL for stroke volume, and 0.3 ± 1.8% for ejection fraction. We conclude that left ventricular functional parameters can be obtained under 5 min from short-axis functional cardiac magnetic resonance images using automatic contour detection methods. Manual correction more than doubles analysis time, with minimal impact on left ventricular volumes and ejection fraction. Copyright © 2011 Wiley Periodicals, Inc.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-26
... Testing of Certain High Production Volume Chemicals; Second Group of Chemicals; Technical Correction... production volume (HPV) chemical substances to obtain screening level data for health and environmental effects and chemical fate. This document is being issued to correct a typographical error concerning the...
NASA Astrophysics Data System (ADS)
Tang, Jing; Wang, Xinhui; Gao, Xiangzhen; Segars, W. Paul; Lodge, Martin A.; Rahmim, Arman
2017-06-01
ECG gated cardiac PET imaging measures functional parameters such as left ventricle (LV) ejection fraction (EF), providing diagnostic and prognostic information for management of patients with coronary artery disease (CAD). Respiratory motion degrades spatial resolution and affects the accuracy in measuring the LV volumes for EF calculation. The goal of this study is to systematically investigate the effect of respiratory motion correction on the estimation of end-diastolic volume (EDV), end-systolic volume (ESV), and EF, especially on the separation of normal and abnormal EFs. We developed a respiratory motion incorporated 4D PET image reconstruction technique which uses all gated-frame data to acquire a motion-suppressed image. Using the standard XCAT phantom and two individual-specific volunteer XCAT phantoms, we simulated dual-gated myocardial perfusion imaging data for normally and abnormally beating hearts. With and without respiratory motion correction, we measured the EDV, ESV, and EF from the cardiac-gated reconstructed images. For all the phantoms, the estimated volumes increased and the biases significantly reduced with motion correction compared with those without. Furthermore, the improvement of ESV measurement in the abnormally beating heart led to better separation of normal and abnormal EFs. The simulation study demonstrated the significant effect of respiratory motion correction on cardiac imaging data with motion amplitude as small as 0.7 cm. The larger the motion amplitude the more improvement respiratory motion correction brought about on the EF measurement. Using data-driven respiratory gating, we also demonstrated the effect of respiratory motion correction on estimating the above functional parameters from list mode patient data. Respiratory motion correction has been shown to improve the accuracy of EF measurement in clinical cardiac PET imaging.
NASA Astrophysics Data System (ADS)
Oh, Jungsu S.; Kim, Jae Seung; Chae, Sun Young; Oh, Minyoung; Oh, Seung Jun; Cha, Seung Nam; Chang, Ho-Jong; Lee, Chong Sik; Lee, Jae Hong
2017-03-01
We present an optimized voxelwise statistical parametric mapping (SPM) of partial-volume (PV)-corrected positron emission tomography (PET) of 11C Pittsburgh Compound B (PiB), incorporating the anatomical precision of magnetic resonance image (MRI) and amyloid β (A β) burden-specificity of PiB PET. First, we applied region-based partial-volume correction (PVC), termed the geometric transfer matrix (GTM) method, to PiB PET, creating MRI-based lobar parcels filled with mean PiB uptakes. Then, we conducted a voxelwise PVC by multiplying the original PET by the ratio of a GTM-based PV-corrected PET to a 6-mm-smoothed PV-corrected PET. Finally, we conducted spatial normalizations of the PV-corrected PETs onto the study-specific template. As such, we increased the accuracy of the SPM normalization and the tissue specificity of SPM results. Moreover, lobar smoothing (instead of whole-brain smoothing) was applied to increase the signal-to-noise ratio in the image without degrading the tissue specificity. Thereby, we could optimize a voxelwise group comparison between subjects with high and normal A β burdens (from 10 patients with Alzheimer's disease, 30 patients with Lewy body dementia, and 9 normal controls). Our SPM framework outperformed than the conventional one in terms of the accuracy of the spatial normalization (85% of maximum likelihood tissue classification volume) and the tissue specificity (larger gray matter, and smaller cerebrospinal fluid volume fraction from the SPM results). Our SPM framework optimized the SPM of a PV-corrected A β PET in terms of anatomical precision, normalization accuracy, and tissue specificity, resulting in better detection and localization of A β burdens in patients with Alzheimer's disease and Lewy body dementia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Du, Kaifang; Reinhardt, Joseph M.; Christensen, Gary E.
2013-12-15
Purpose: Four-dimensional computed tomography (4DCT) can be used to make measurements of pulmonary function longitudinally. The sensitivity of such measurements to identify change depends on measurement uncertainty. Previously, intrasubject reproducibility of Jacobian-based measures of lung tissue expansion was studied in two repeat prior-RT 4DCT human acquisitions. Difference in respiratory effort such as breathing amplitude and frequency may affect longitudinal function assessment. In this study, the authors present normalization schemes that correct ventilation images for variations in respiratory effort and assess the reproducibility improvement after effort correction.Methods: Repeat 4DCT image data acquired within a short time interval from 24 patients priormore » to radiation therapy (RT) were used for this analysis. Using a tissue volume preserving deformable image registration algorithm, Jacobian ventilation maps in two scanning sessions were computed and compared on the same coordinate for reproducibility analysis. In addition to computing the ventilation maps from end expiration to end inspiration, the authors investigated the effort normalization strategies using other intermediated inspiration phases upon the principles of equivalent tidal volume (ETV) and equivalent lung volume (ELV). Scatter plots and mean square error of the repeat ventilation maps and the Jacobian ratio map were generated for four conditions: no effort correction, global normalization, ETV, and ELV. In addition, gamma pass rate was calculated from a modified gamma index evaluation between two ventilation maps, using acceptance criterions of 2 mm distance-to-agreement and 5% ventilation difference.Results: The pattern of regional pulmonary ventilation changes as lung volume changes. All effort correction strategies improved reproducibility when changes in respiratory effort were greater than 150 cc (p < 0.005 with regard to the gamma pass rate). Improvement of reproducibility was correlated with respiratory effort difference (R = 0.744 for ELV in the cohort with tidal volume difference greater than 100 cc). In general for all subjects, global normalization, ETV and ELV significantly improved reproducibility compared to no effort correction (p = 0.009, 0.002, 0.005 respectively). When tidal volume difference was small (less than 100 cc), none of the three effort correction strategies improved reproducibility significantly (p = 0.52, 0.46, 0.46 respectively). For the cohort (N = 13) with tidal volume difference greater than 100 cc, the average gamma pass rate improves from 57.3% before correction to 66.3% after global normalization, and 76.3% after ELV. ELV was found to be significantly better than global normalization (p = 0.04 for all subjects, and p = 0.003 for the cohort with tidal volume difference greater than 100 cc).Conclusions: All effort correction strategies improve the reproducibility of the authors' pulmonary ventilation measures, and the improvement of reproducibility is highly correlated with the changes in respiratory effort. ELV gives better results as effort difference increase, followed by ETV, then global. However, based on the spatial and temporal heterogeneity in the lung expansion rate, a single scaling factor (e.g., global normalization) appears to be less accurate to correct the ventilation map when changes in respiratory effort are large.« less
A mass-balanced definition of corrected retention volume in gas chromatography.
Kurganov, A
2007-05-25
The mass balance equation of a chromatographic system using a compressible moving phase has been compiled for mass flow of the mobile phase instead of traditional volumetric flow allowing solution of the equation in an analytical form. The relation obtained correlates retention volume measured under ambient conditions with the partition coefficient of the solute. Compared to the relation in the ideal chromatographic system the equation derived contains an additional correction term accounting for the compressibility of the moving phase. When the retention volume is measured under the mean column pressure and column temperature the correction term is reduced to unit and the relation is simplified to those known for the ideal system. This volume according to International Union of Pure and Applied Chemistry (IUPAC) is called the corrected retention volume.
NASA Astrophysics Data System (ADS)
Thomas, Philipp; Straube, Arthur V.; Grima, Ramon
2010-11-01
Chemical reactions inside cells occur in compartment volumes in the range of atto- to femtoliters. Physiological concentrations realized in such small volumes imply low copy numbers of interacting molecules with the consequence of considerable fluctuations in the concentrations. In contrast, rate equation models are based on the implicit assumption of infinitely large numbers of interacting molecules, or equivalently, that reactions occur in infinite volumes at constant macroscopic concentrations. In this article we compute the finite-volume corrections (or equivalently the finite copy number corrections) to the solutions of the rate equations for chemical reaction networks composed of arbitrarily large numbers of enzyme-catalyzed reactions which are confined inside a small subcellular compartment. This is achieved by applying a mesoscopic version of the quasisteady-state assumption to the exact Fokker-Planck equation associated with the Poisson representation of the chemical master equation. The procedure yields impressively simple and compact expressions for the finite-volume corrections. We prove that the predictions of the rate equations will always underestimate the actual steady-state substrate concentrations for an enzyme-reaction network confined in a small volume. In particular we show that the finite-volume corrections increase with decreasing subcellular volume, decreasing Michaelis-Menten constants, and increasing enzyme saturation. The magnitude of the corrections depends sensitively on the topology of the network. The predictions of the theory are shown to be in excellent agreement with stochastic simulations for two types of networks typically associated with protein methylation and metabolism.
Zhurova, A A; Ekstrem, A V; Popov, A S
2010-01-01
The method of long-term continuous low-volume infusion of hydroxyethyl starch (low-flow low volume correction HES) is administrated for correction of fluid balance disorders. The method is aimed to improve the outcomes in preeclamsia patients with multiple organ dysfunction and failure, as the most severe manifestation of system inflammatory response syndrome. After 4 days of the intensive care with application of the developed method in patients with preeclamsia the total body water level is decreased to the normal physiological level, the oedemas are significantly reduced or ceased, the haemodynamics stabilizes, which leads to the reduce of neurologic symptoms. The suggested method of low-flow low volume correction HES, in dose of 15 ml/kg/day is a significant addition to the existing methods of homeostasis and preeclampsia correction.
Swift, Andrew J; Rajaram, Smitha; Campbell, Michael J; Hurdman, Judith; Thomas, Steve; Capener, Dave; Elliot, Charlie; Condliffe, Robin; Wild, Jim M; Kiely, David G
2014-01-01
There are limited data on the prognostic value of cardiovascular magnetic resonance measurements in idiopathic pulmonary arterial hypertension, with no studies investigating the impact of correction of cardiovascular magnetic resonance indices for age and sex on prognostic value. Consecutive patients with idiopathic pulmonary arterial hypertension underwent cardiovascular magnetic resonance imaging at 1.5T. Steady-state free precession cardiac volumes and mass measurements were corrected for age, sex, and body surface area according to reference data and prognostic significance assessed. A total of 80 patients with idiopathic pulmonary arterial hypertension were identified, and 23 patients died during the mean follow-up of 32±14 months. Corrected for age, sex, and body surface area, right ventricular end-systolic volume (P=0.004) strongly predicted mortality, independent of World Health Organization functional class, mean right atrial pressure, cardiac index, and mixed venous oxygen saturations. Consideration should be given to correcting cardiovascular magnetic resonance measures for age, sex, and body surface area, particularly given the changing demographics of patients with idiopathic pulmonary arterial hypertension. Corrected right ventricular end-systolic volume is a strong prognostic marker in idiopathic pulmonary arterial hypertension, independent of invasively derived measurements, mean right atrial pressure cardiac index, and mixed venous oxygen saturations.
Does early tetralogy of Fallot total correction give better final lung volumes?
Sadeghi, Hasan Allah; Miri, Seyed Reza; Bakhshandeh, Hooman; Mirmesdagh, Yalda; Paziraee, Nazita
2013-06-01
Pulmonary blood flow may affect lung development in adulthood. Early total correction of tetralogy of Fallot may affect development of final lung volumes. We evaluated the effect of age at total correction on lung volumes years after the operation. In a retrospective cohort study on patients with totally corrected tetralogy of Fallot (mean age, 13.40 years at the time of follow-up), forced vital capacity, slow vital capacity, forced expiratory volume in 1 s, and other parameters were measured 154.8 ± 46.25 months after the operation. Comparison were made of 3 groups: ≤2-, 2-8-, and >8-years old at the time of total correction surgery. Among 322 enrolled patients, the mean values of the follow-up spirometry results in ≤2-, 2-8-, >8-year-olds and the percentage of predicted values were respectively: vital capacity: 4.46 ± 0.57 L (107% ± 10.96%), 3.89 ± 0.58 L (91.10% ± 12.25%), 3.25 ± 0.48 L (82.35% ± 10.62%), p < 0.001; forced vital capacity: 4.28 ± 0.63 L (95.90% ± 18.77%), 3.76 ± 0.58 L (90.83% ± 12.52%), 3.14 ± 0.49 L (83.26% ± 11.71%), p < 0.001; forced expiratory volume in 1 s: 4.22 ± 0.63 L (104.84% ± 13.64%), 3.66 ± 0.58 L (90.61% ± 12.59%), 3.02 ± 0.48 L (84.31% ± 12%), p < 0.001. Early correction of defects or reestablishments of perfusion of tetralogy of Fallot before completion of lung development might improve final adulthood lung volumes and capacities. It is better to consider total correction for all tetralogy of Fallot patients below 2-years old, or at least below 8-years old, if it is technically possible.
Schiavo, Luigi; Pilone, Vincenzo; Rossetti, Gianluca; Barbarisi, Alfonso; Cesaretti, Manuela; Iannelli, Antonio
2018-03-03
Before bariatric surgery (BS), moderate weight loss, left hepatic lobe volume reduction, and micronutrient deficiency (MD) identification and correction are desirable. The objective of this study was to assess the safety and the effectiveness of a 4-week preoperative ketogenic micronutrient-enriched diet (KMED) in reducing body weight (BW), left hepatic lobe volume, and correcting MD in patients scheduled for BS. In this prospective pilot study, a cohort of morbidly obese patients (n = 27, 17 females, 10 males) with a mean body mass index (BMI) of 45.2 kg/m 2 scheduled for BS underwent a 4-week preoperative KMED. Their BW, BMI, fat mass (FM), fat-free mass (FFM), resting metabolic rate (RMR), left hepatic lobe volume, micronutrient status, and biochemical and metabolic patterns were measured before and after the 4-week KMED. Patient compliance was assessed by validated questionnaires (3-day estimated food records and 72-h recall). Qualitative methods (5-point Likert questionnaire) were used to measure diet acceptability and side effects. All patients completed the study. We observed highly significant decreases in BW (- 10.3%, p < 0.001, in males; - 8.2%, p < 0.001, in females), left hepatic lobe volume (- 19.8%, p < 0.001), and an amelioration of patient micronutrient status. All patients showed a high frequency of acceptability and compliance in following the diet. No adverse side effect was reported. This study demonstrates that a 4-week preoperative KMED is safe and effective in reducing BW, left hepatic lobe volume, and correcting MD in obese patients scheduled for BS.
Coello, Christopher; Willoch, Frode; Selnes, Per; Gjerstad, Leif; Fladby, Tormod; Skretting, Arne
2013-05-15
A voxel-based algorithm to correct for partial volume effect in PET brain volumes is presented. This method (named LoReAn) is based on MRI based segmentation of anatomical regions and accurate measurements of the effective point spread function of the PET imaging process. The objective is to correct for the spill-out of activity from high-uptake anatomical structures (e.g. grey matter) into low-uptake anatomical structures (e.g. white matter) in order to quantify physiological uptake in the white matter. The new algorithm is presented and validated against the state of the art region-based geometric transfer matrix (GTM) method with synthetic and clinical data. Using synthetic data, both bias and coefficient of variation were improved in the white matter region using LoReAn compared to GTM. An increased number of anatomical regions doesn't affect the bias (<5%) and misregistration affects equally LoReAn and GTM algorithms. The LoReAn algorithm appears to be a simple and promising voxel-based algorithm for studying metabolism in white matter regions. Copyright © 2013 Elsevier Inc. All rights reserved.
Spectral-Based Volume Sensor Prototype, Post-VS4 Test Series Algorithm Development
2009-04-30
Computer Pcorr Probabilty / Percentage of Correct Classification (# Correct / # Total) PD PhotoDiode Pd Probabilty / Percentage of Detection (# Correct...Detections / Total of Sources) Pfa Probabilty / Percentage of False Alarm (# FAs / Total # of Sources) SBVS Spectral-Based Volume Sensor SFA Smoke and
Lind, Annika; Parkkola, Riitta; Lehtonen, Liisa; Munck, Petriina; Maunu, Jonna; Lapinleimu, Helena; Haataja, Leena
2011-08-01
Altered brain volumes and associations between volumes and developmental outcomes have been reported in prematurely born children. To assess which regional brain volumes are different in very low birth weight (VLBW) children without neurodevelopmental impairments ([NDI] cerebral palsy, hearing loss, blindness and significantly delayed cognitive performance) compared with VLBW children with NDI, and to evaluate the association between regional brain volumes at term-equivalent age and cognitive development and neurological performance at a corrected age of 2 years. The study group consisted of a regional cohort of 164 VLBW children, divided into one group of children without NDI (n = 148) and one group of children with NDI (n = 16). Brain (MRI) was performed at term-equivalent age, from which brain volumes were manually analysed. Cognitive development was assessed with the Bayley Scales of Infant Development II (BSID-II), and neurological performance with the Hammersmith Infant Neurological Examination at the corrected age of 2 years. The volumes of total brain tissue, cerebrum, frontal lobes, basal ganglia and thalami, and cerebellum were significantly smaller, and the volume of the ventricles significantly larger, in the children with NDI than in those without NDI. Even in children without NDI, a smaller cerebellar volume was significantly correlated with poor neurological performance at 2 years of corrected age. Volumetric analysis at brain MRI can provide an additional parameter for early prediction of outcome in VLBW children.
Andersson, Jesper L R; Graham, Mark S; Drobnjak, Ivana; Zhang, Hui; Filippini, Nicola; Bastiani, Matteo
2017-05-15
Most motion correction methods work by aligning a set of volumes together, or to a volume that represents a reference location. These are based on an implicit assumption that the subject remains motionless during the several seconds it takes to acquire all slices in a volume, and that any movement occurs in the brief moment between acquiring the last slice of one volume and the first slice of the next. This is clearly an approximation that can be more or less good depending on how long it takes to acquire one volume and in how rapidly the subject moves. In this paper we present a method that increases the temporal resolution of the motion correction by modelling movement as a piecewise continous function over time. This intra-volume movement correction is implemented within a previously presented framework that simultaneously estimates distortions, movement and movement-induced signal dropout. We validate the method on highly realistic simulated data containing all of these effects. It is demonstrated that we can estimate the true movement with high accuracy, and that scalar parameters derived from the data, such as fractional anisotropy, are estimated with greater fidelity when data has been corrected for intra-volume movement. Importantly, we also show that the difference in fidelity between data affected by different amounts of movement is much reduced when taking intra-volume movement into account. Additional validation was performed on data from a healthy volunteer scanned when lying still and when performing deliberate movements. We show an increased correspondence between the "still" and the "movement" data when the latter is corrected for intra-volume movement. Finally we demonstrate a big reduction in the telltale signs of intra-volume movement in data acquired on elderly subjects. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Phase aberration simulation study of MRgFUS breast treatments
Farrer, Alexis I.; Almquist, Scott; Dillon, Christopher R.; Neumayer, Leigh A.; Parker, Dennis L.; Christensen, Douglas A.; Payne, Allison
2016-01-01
Purpose: This simulation study evaluates the effects of phase aberration in breast MR-guided focused ultrasound (MRgFUS) ablation treatments performed with a phased-array transducer positioned laterally to the breast. A quantification of these effects in terms of thermal dose delivery and the potential benefits of phase correction is demonstrated in four heterogeneous breast numerical models. Methods: To evaluate the effects of varying breast tissue properties on the quality of the focus, four female volunteers with confirmed benign fibroadenomas were imaged using 3T MRI. These images were segmented into numerical models with six tissue types, with each tissue type assigned standard acoustic properties from the literature. Simulations for a single-plane 16-point raster-scan treatment trajectory centered in a fibroadenoma in each modeled breast were performed for a breast-specific MRgFUS system. At each of the 16 points, pressure patterns both with and without applying a phase correction technique were determined with the hybrid-angular spectrum method. Corrected phase patterns were obtained using a simulation-based phase aberration correction technique to adjust each element’s transmit phase to obtain maximized constructive interference at the desired focus. Thermal simulations were performed for both the corrected and uncorrected pressure patterns using a finite-difference implementation of the Pennes bioheat equation. The effect of phase correction was evaluated through comparison of thermal dose accumulation both within and outside a defined treatment volume. Treatment results using corrected and uncorrected phase aberration simulations were compared by evaluating the power required to achieve a 20 °C temperature rise at the first treatment location. The extent of the volumes that received a minimum thermal dose of 240 CEM at 43 °C inside the intended treatment volume as well as the volume in the remaining breast tissues was also evaluated in the form of a dose volume ratio (DVR), a DVR percent change between corrected and uncorrected phases, and an additional metric that measured phase spread. Results: With phase aberration correction applied, there was an improvement in the focus for all breast anatomies as quantified by a reduction in power required (13%–102%) to reach 20 °C when compared to uncorrected simulations. Also, the DVR percent change increased by 5%–77% in seven out of eight cases, indicating an improvement to the treatment as measured by a reduction in thermal dose deposited to the nontreatment tissues. Breast compositions with a higher degree of heterogeneity along the ultrasound beam path showed greater reductions in thermal dose delivered outside of the treatment volume with correction applied than beam trajectories that propagated through more homogeneous breast compositions. An increasing linear trend was observed between the DVR percent change and the phase-spread metric (R2 = 0.68). Conclusions: These results indicate that performing phase aberration correction for breast MRgFUS treatments is beneficial for the small-aperture transducer (14.4 × 9.8 cm) evaluated in this work. While all breast anatomies could benefit from phase aberration correction, greater benefits are observed in more heterogeneous anatomies. PMID:26936722
Shidahara, Miho; Thomas, Benjamin A; Okamura, Nobuyuki; Ibaraki, Masanobu; Matsubara, Keisuke; Oyama, Senri; Ishikawa, Yoichi; Watanuki, Shoichi; Iwata, Ren; Furumoto, Shozo; Tashiro, Manabu; Yanai, Kazuhiko; Gonda, Kohsuke; Watabe, Hiroshi
2017-08-01
To suppress partial volume effect (PVE) in brain PET, there have been many algorithms proposed. However, each methodology has different property due to its assumption and algorithms. Our aim of this study was to investigate the difference among partial volume correction (PVC) method for tau and amyloid PET study. We investigated two of the most commonly used PVC methods, Müller-Gärtner (MG) and geometric transfer matrix (GTM) and also other three methods for clinical tau and amyloid PET imaging. One healthy control (HC) and one Alzheimer's disease (AD) PET studies of both [ 18 F]THK5351 and [ 11 C]PIB were performed using a Eminence STARGATE scanner (Shimadzu Inc., Kyoto, Japan). All PET images were corrected for PVE by MG, GTM, Labbé (LABBE), Regional voxel-based (RBV), and Iterative Yang (IY) methods, with segmented or parcellated anatomical information processed by FreeSurfer, derived from individual MR images. PVC results of 5 algorithms were compared with the uncorrected data. In regions of high uptake of [ 18 F]THK5351 and [ 11 C]PIB, different PVCs demonstrated different SUVRs. The degree of difference between PVE uncorrected and corrected depends on not only PVC algorithm but also type of tracer and subject condition. Presented PVC methods are straight-forward to implement but the corrected images require careful interpretation as different methods result in different levels of recovery.
It Is Chloride Depletion Alkalosis, Not Contraction Alkalosis
Galla, John H.
2012-01-01
Maintenance of metabolic alkalosis generated by chloride depletion is often attributed to volume contraction. In balance and clearance studies in rats and humans, we showed that chloride repletion in the face of persisting alkali loading, volume contraction, and potassium and sodium depletion completely corrects alkalosis by a renal mechanism. Nephron segment studies strongly suggest the corrective response is orchestrated in the collecting duct, which has several transporters integral to acid-base regulation, the most important of which is pendrin, a luminal Cl/HCO3− exchanger. Chloride depletion alkalosis should replace the notion of contraction alkalosis. PMID:22223876
NASA Astrophysics Data System (ADS)
Sumitomo, Yoske; Tye, S.-H. Henry; Wong, Sam S. C.
2013-07-01
We study a racetrack model in the presence of the leading α'-correction in flux compactification in Type IIB string theory, for the purpose of getting conceivable de-Sitter vacua in the large compactified volume approximation. Unlike the Kähler Uplift model studied previously, the α'-correction is more controllable for the meta-stable de-Sitter vacua in the racetrack case since the constraint on the compactified volume size is very much relaxed. We find that the vacuum energy density Λ for de-Sitter vacua approaches zero exponentially as the volume grows. We also analyze properties of the probability distribution of Λ in this class of models. As in other cases studied earlier, the probability distribution again peaks sharply at Λ = 0. We also study the Racetrack Kähler Uplift model in the Swiss-Cheese type model.
Anatomical-based partial volume correction for low-dose dedicated cardiac SPECT/CT
NASA Astrophysics Data System (ADS)
Liu, Hui; Chan, Chung; Grobshtein, Yariv; Ma, Tianyu; Liu, Yaqiang; Wang, Shi; Stacy, Mitchel R.; Sinusas, Albert J.; Liu, Chi
2015-09-01
Due to the limited spatial resolution, partial volume effect has been a major degrading factor on quantitative accuracy in emission tomography systems. This study aims to investigate the performance of several anatomical-based partial volume correction (PVC) methods for a dedicated cardiac SPECT/CT system (GE Discovery NM/CT 570c) with focused field-of-view over a clinically relevant range of high and low count levels for two different radiotracer distributions. These PVC methods include perturbation geometry transfer matrix (pGTM), pGTM followed by multi-target correction (MTC), pGTM with known concentration in blood pool, the former followed by MTC and our newly proposed methods, which perform the MTC method iteratively, where the mean values in all regions are estimated and updated by the MTC-corrected images each time in the iterative process. The NCAT phantom was simulated for cardiovascular imaging with 99mTc-tetrofosmin, a myocardial perfusion agent, and 99mTc-red blood cell (RBC), a pure intravascular imaging agent. Images were acquired at six different count levels to investigate the performance of PVC methods in both high and low count levels for low-dose applications. We performed two large animal in vivo cardiac imaging experiments following injection of 99mTc-RBC for evaluation of intramyocardial blood volume (IMBV). The simulation results showed our proposed iterative methods provide superior performance than other existing PVC methods in terms of image quality, quantitative accuracy, and reproducibility (standard deviation), particularly for low-count data. The iterative approaches are robust for both 99mTc-tetrofosmin perfusion imaging and 99mTc-RBC imaging of IMBV and blood pool activity even at low count levels. The animal study results indicated the effectiveness of PVC to correct the overestimation of IMBV due to blood pool contamination. In conclusion, the iterative PVC methods can achieve more accurate quantification, particularly for low count cardiac SPECT studies, typically obtained from low-dose protocols, gated studies, and dynamic applications.
ERIC Educational Resources Information Center
Rice, Eric; And Others
To identify the issues, characteristics, barriers, and needs related to vocational education provisions in Southeastern correctional institutions, a project was developed. Survey data was collected through a 100% sample of adult and juvenile correctional facilities in seven states. Study procedures utilized a combination of state level interviews,…
40 CFR 60.54a - Standard for municipal waste combustor acid gases.
Code of Federal Regulations, 2010 CFR
2010-07-01
... for Municipal Waste Combustors for Which Construction is Commenced After December 20, 1989 and on or... weight or volume) or 30 parts per million by volume, corrected to 7 percent oxygen (dry basis), whichever... by volume, corrected to 7 percent oxygen (dry basis), whichever is less stringent. ...
Tropical forest tree stands characterization with L-band polarimetric radar
NASA Technical Reports Server (NTRS)
Wu, Shih-Tseng
1990-01-01
The effectiveness of using L-band polarimetric data to determine tropical tree-stand parameters is discussed with specific attention given to the correction of the radar data. Tree-parameter data from ground studies is compared to L-band polarimetric data (in both uncorrected and topographically corrected forms) for two test areas. The test sites are at two different elevations but both include 81 test plots with topographic data and tree-characteristic data given. Synthetic-aperture radar (SAR) data are found to be related to bole volume and tree volume, and the topographically corrected data show results similar to the uncorrected data. Similar r-values are given for both data sets because the data with incidence-angle values below 35 and above 55 are removed. Topographical correction is important when local incidence angles exceed the limits.
Su, Yi; Blazey, Tyler M; Owen, Christopher J; Christensen, Jon J; Friedrichsen, Karl; Joseph-Mathurin, Nelly; Wang, Qing; Hornbeck, Russ C; Ances, Beau M; Snyder, Abraham Z; Cash, Lisa A; Koeppe, Robert A; Klunk, William E; Galasko, Douglas; Brickman, Adam M; McDade, Eric; Ringman, John M; Thompson, Paul M; Saykin, Andrew J; Ghetti, Bernardino; Sperling, Reisa A; Johnson, Keith A; Salloway, Stephen P; Schofield, Peter R; Masters, Colin L; Villemagne, Victor L; Fox, Nick C; Förster, Stefan; Chen, Kewei; Reiman, Eric M; Xiong, Chengjie; Marcus, Daniel S; Weiner, Michael W; Morris, John C; Bateman, Randall J; Benzinger, Tammie L S
2016-01-01
Amyloid imaging plays an important role in the research and diagnosis of dementing disorders. Substantial variation in quantitative methods to measure brain amyloid burden exists in the field. The aim of this work is to investigate the impact of methodological variations to the quantification of amyloid burden using data from the Dominantly Inherited Alzheimer's Network (DIAN), an autosomal dominant Alzheimer's disease population. Cross-sectional and longitudinal [11C]-Pittsburgh Compound B (PiB) PET imaging data from the DIAN study were analyzed. Four candidate reference regions were investigated for estimation of brain amyloid burden. A regional spread function based technique was also investigated for the correction of partial volume effects. Cerebellar cortex, brain-stem, and white matter regions all had stable tracer retention during the course of disease. Partial volume correction consistently improves sensitivity to group differences and longitudinal changes over time. White matter referencing improved statistical power in the detecting longitudinal changes in relative tracer retention; however, the reason for this improvement is unclear and requires further investigation. Full dynamic acquisition and kinetic modeling improved statistical power although it may add cost and time. Several technical variations to amyloid burden quantification were examined in this study. Partial volume correction emerged as the strategy that most consistently improved statistical power for the detection of both longitudinal changes and across-group differences. For the autosomal dominant Alzheimer's disease population with PiB imaging, utilizing brainstem as a reference region with partial volume correction may be optimal for current interventional trials. Further investigation of technical issues in quantitative amyloid imaging in different study populations using different amyloid imaging tracers is warranted.
Su, Yi; Blazey, Tyler M.; Owen, Christopher J.; Christensen, Jon J.; Friedrichsen, Karl; Joseph-Mathurin, Nelly; Wang, Qing; Hornbeck, Russ C.; Ances, Beau M.; Snyder, Abraham Z.; Cash, Lisa A.; Koeppe, Robert A.; Klunk, William E.; Galasko, Douglas; Brickman, Adam M.; McDade, Eric; Ringman, John M.; Thompson, Paul M.; Saykin, Andrew J.; Ghetti, Bernardino; Sperling, Reisa A.; Johnson, Keith A.; Salloway, Stephen P.; Schofield, Peter R.; Masters, Colin L.; Villemagne, Victor L.; Fox, Nick C.; Förster, Stefan; Chen, Kewei; Reiman, Eric M.; Xiong, Chengjie; Marcus, Daniel S.; Weiner, Michael W.; Morris, John C.; Bateman, Randall J.; Benzinger, Tammie L. S.
2016-01-01
Amyloid imaging plays an important role in the research and diagnosis of dementing disorders. Substantial variation in quantitative methods to measure brain amyloid burden exists in the field. The aim of this work is to investigate the impact of methodological variations to the quantification of amyloid burden using data from the Dominantly Inherited Alzheimer’s Network (DIAN), an autosomal dominant Alzheimer’s disease population. Cross-sectional and longitudinal [11C]-Pittsburgh Compound B (PiB) PET imaging data from the DIAN study were analyzed. Four candidate reference regions were investigated for estimation of brain amyloid burden. A regional spread function based technique was also investigated for the correction of partial volume effects. Cerebellar cortex, brain-stem, and white matter regions all had stable tracer retention during the course of disease. Partial volume correction consistently improves sensitivity to group differences and longitudinal changes over time. White matter referencing improved statistical power in the detecting longitudinal changes in relative tracer retention; however, the reason for this improvement is unclear and requires further investigation. Full dynamic acquisition and kinetic modeling improved statistical power although it may add cost and time. Several technical variations to amyloid burden quantification were examined in this study. Partial volume correction emerged as the strategy that most consistently improved statistical power for the detection of both longitudinal changes and across-group differences. For the autosomal dominant Alzheimer’s disease population with PiB imaging, utilizing brainstem as a reference region with partial volume correction may be optimal for current interventional trials. Further investigation of technical issues in quantitative amyloid imaging in different study populations using different amyloid imaging tracers is warranted. PMID:27010959
Wennberg, Berit M; Baumann, Pia; Gagliardi, Giovanna; Nyman, Jan; Drugge, Ninni; Hoyer, Morten; Traberg, Anders; Nilsson, Kristina; Morhed, Elisabeth; Ekberg, Lars; Wittgren, Lena; Lund, Jo-Åsmund; Levin, Nina; Sederholm, Christer; Lewensohn, Rolf; Lax, Ingmar
2011-05-01
In SBRT of lung tumours no established relationship between dose-volume parameters and the incidence of lung toxicity is found. The aim of this study is to compare the LQ model and the universal survival curve (USC) to calculate biologically equivalent doses in SBRT to see if this will improve knowledge on this relationship. Toxicity data on radiation pneumonitis grade 2 or more (RP2+) from 57 patients were used, 10.5% were diagnosed with RP2+. The lung DVHs were corrected for fractionation (LQ and USC) and analysed with the Lyman- Kutcher-Burman (LKB) model. In the LQ-correction α/β = 3 Gy was used and the USC parameters used were: α/β = 3 Gy, D(0) = 1.0 Gy, [Formula: see text] = 10, α = 0.206 Gy(-1) and d(T) = 5.8 Gy. In order to understand the relative contribution of different dose levels to the calculated NTCP the concept of fractional NTCP was used. This might give an insight to the questions of whether "high doses to small volumes" or "low doses to large volumes" are most important for lung toxicity. NTCP analysis with the LKB-model using parameters m = 0.4, D(50) = 30 Gy resulted for the volume dependence parameter (n) with LQ correction n = 0.87 and with USC correction n = 0.71. Using parameters m = 0.3, D(50) = 20 Gy n = 0.93 with LQ correction and n = 0.83 with USC correction. In SBRT of lung tumours, NTCP modelling of lung toxicity comparing models (LQ,USC) for fractionation correction, shows that low dose contribute less and high dose more to the NTCP when using the USC-model. Comparing NTCP modelling of SBRT data and data from breast cancer, lung cancer and whole lung irradiation implies that the response of the lung is treatment specific. More data are however needed in order to have a more reliable modelling.
Analytical-Based Partial Volume Recovery in Mouse Heart Imaging
NASA Astrophysics Data System (ADS)
Dumouchel, Tyler; deKemp, Robert A.
2011-02-01
Positron emission tomography (PET) is a powerful imaging modality that has the ability to yield quantitative images of tracer activity. Physical phenomena such as photon scatter, photon attenuation, random coincidences and spatial resolution limit quantification potential and must be corrected to preserve the accuracy of reconstructed images. This study focuses on correcting the partial volume effects that arise in mouse heart imaging when resolution is insufficient to resolve the true tracer distribution in the myocardium. The correction algorithm is based on fitting 1D profiles through the myocardium in gated PET images to derive myocardial contours along with blood, background and myocardial activity. This information is interpolated onto a 2D grid and convolved with the tomograph's point spread function to derive regional recovery coefficients enabling partial volume correction. The point spread function was measured by placing a line source inside a small animal PET scanner. PET simulations were created based on noise properties measured from a reconstructed PET image and on the digital MOBY phantom. The algorithm can estimate the myocardial activity to within 5% of the truth when different wall thicknesses, backgrounds and noise properties are encountered that are typical of healthy FDG mouse scans. The method also significantly improves partial volume recovery in simulated infarcted tissue. The algorithm offers a practical solution to the partial volume problem without the need for co-registered anatomic images and offers a basis for improved quantitative 3D heart imaging.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boer, Johan de; Wolf, Anne Lisa; Szeto, Yenny Z.
2015-04-01
Purpose: Rotations of the prostate gland induce considerable geometric uncertainties in prostate cancer radiation therapy. Collimator and gantry angle adjustments can correct these rotations in intensity modulated radiation therapy. Modern volumetric modulated arc therapy (VMAT) treatments, however, include a wide range of beam orientations that differ in modulation, and corrections require dynamic collimator rotations. The aim of this study was to implement a rotation correction strategy for VMAT dose delivery and validate it for left-right prostate rotations. Methods and Materials: Clinical VMAT treatment plans of 5 prostate cancer patients were used. Simulated left-right prostate rotations between +15° and −15° weremore » corrected by collimator rotations. We compared corrected and uncorrected plans by dose volume histograms, minimum dose (D{sub min}) to the prostate, bladder surface receiving ≥78 Gy (S78) and rectum equivalent uniform dose (EUD; n=0.13). Each corrected plan was delivered to a phantom, and its deliverability was evaluated by γ-evaluation between planned and delivered dose, which was reconstructed from portal images acquired during delivery. Results: On average, clinical target volume minimum dose (D{sub min}) decreased up to 10% without corrections. Negative left-right rotations were corrected almost perfectly, whereas D{sub min} remained within 4% for positive rotations. Bladder S78 and rectum EUD of the corrected plans matched those of the original plans. The average pass rate for the corrected plans delivered to the phantom was 98.9% at 3% per 3 mm gamma criteria. The measured dose in the planning target volume approximated the original dose, rotated around the simulated left-right angle, well. Conclusions: It is feasible to dynamically adjust the collimator angle during VMAT treatment delivery to correct for prostate rotations. This technique can safely correct for left-right prostate rotations up to 15°.« less
Partial volume correction of magnetic resonance spectroscopic imaging
NASA Astrophysics Data System (ADS)
Lu, Yao; Wu, Dee; Magnotta, Vincent A.
2007-03-01
The ability to study the biochemical composition of the brain is becoming important to better understand neurodegenerative and neurodevelopmental disorders. Magnetic Resonance Spectroscopy (MRS) can non-invasively provide quantification of brain metabolites in localized regions. The reliability of MRS is limited in part due to partial volume artifacts. This results from the relatively large voxels that are required to acquire sufficient signal-to-noise ratios for the studies. Partial volume artifacts result when a MRS voxel contains a mixture of tissue types. Concentrations of metabolites vary from tissue to tissue. When a voxel contains a heterogeneous tissue composition, the spectroscopic signal acquired from this voxel will consist of the signal from different tissues making reliable measurements difficult. We have developed a novel tool for the estimation of partial volume tissue composition within MRS voxels thus allowing for the correction of partial volume artifacts. In addition, the tool can localize MR spectra to anatomical regions of interest. The tool uses tissue classification information acquired as part of a structural MR scan for the same subject. The tissue classification information is co-registered with the spectroscopic data. The user can quantify the partial volume composition of each voxel and use this information as covariates for metabolite concentrations.
Effect of Malmquist bias on correlation studies with IRAS data base
NASA Technical Reports Server (NTRS)
Verter, Frances
1993-01-01
The relationships between galaxy properties in the sample of Trinchieri et al. (1989) are reexamined with corrections for Malmquist bias. The linear correlations are tested and linear regressions are fit for log-log plots of L(FIR), L(H-alpha), and L(B) as well as ratios of these quantities. The linear correlations for Malmquist bias are corrected using the method of Verter (1988), in which each galaxy observation is weighted by the inverse of its sampling volume. The linear regressions are corrected for Malmquist bias by a new method invented here in which each galaxy observation is weighted by its sampling volume. The results of correlation and regressions among the sample are significantly changed in the anticipated sense that the corrected correlation confidences are lower and the corrected slopes of the linear regressions are lower. The elimination of Malmquist bias eliminates the nonlinear rise in luminosity that has caused some authors to hypothesize additional components of FIR emission.
Partial volume correction using cortical surfaces
NASA Astrophysics Data System (ADS)
Blaasvær, Kamille R.; Haubro, Camilla D.; Eskildsen, Simon F.; Borghammer, Per; Otzen, Daniel; Ostergaard, Lasse R.
2010-03-01
Partial volume effect (PVE) in positron emission tomography (PET) leads to inaccurate estimation of regional metabolic activities among neighbouring tissues with different tracer concentration. This may be one of the main limiting factors in the utilization of PET in clinical practice. Partial volume correction (PVC) methods have been widely studied to address this issue. MRI based PVC methods are well-established.1 Their performance depend on the quality of the co-registration of the MR and PET dataset, on the correctness of the estimated point-spread function (PSF) of the PET scanner and largely on the performance of the segmentation method that divide the brain into brain tissue compartments.1, 2 In the present study a method for PVC is suggested, that utilizes cortical surfaces, to obtain detailed anatomical information. The objectives are to improve the performance of PVC, facilitate a study of the relationship between metabolic activity in the cerebral cortex and cortical thicknesses, and to obtain an improved visualization of PET data. The gray matter metabolic activity after performing PVC was recovered by 99.7 - 99.8 % , in relation to the true activity when testing on simple simulated data with different PSFs and by 97.9 - 100 % when testing on simulated brain PET data at different cortical thicknesses. When studying the relationship between metabolic activities and anatomical structures it was shown on simulated brain PET data, that it is important to correct for PVE in order to get the true relationship.
Hurwitz, Barry E; Coryell, Virginia T; Parker, Meela; Martin, Pedro; Laperriere, Arthur; Klimas, Nancy G; Sfakianakis, George N; Bilsker, Martin S
2009-10-19
The study examined whether deficits in cardiac output and blood volume in a CFS (chronic fatigue syndrome) cohort were present and linked to illness severity and sedentary lifestyle. Follow-up analyses assessed whether differences in cardiac output levels between CFS and control groups were corrected by controlling for cardiac contractility and TBV (total blood volume). The 146 participants were subdivided into two CFS groups based on symptom severity data, severe (n=30) and non-severe (n=26), and two healthy non-CFS control groups based on physical activity, sedentary (n=58) and non-sedentary (n=32). Controls were matched to CFS participants using age, gender, ethnicity and body mass. Echocardiographic measures indicated that the severe CFS participants had 10.2% lower cardiac volume (i.e. stroke index and end-diastolic volume) and 25.1% lower contractility (velocity of circumferential shortening corrected by heart rate) than the control groups. Dual tag blood volume assessments indicated that the CFS groups had lower TBV, PV (plasma volume) and RBCV (red blood cell volume) than control groups. Of the CFS subjects with a TBV deficit (i.e. > or = 8% below ideal levels), the mean+/-S.D. percentage deficit in TBV, PV and RBCV were -15.4+/-4.0, -13.2+/-5.0 and -19.1+/-6.3% respectively. Lower cardiac volume levels in CFS were substantially corrected by controlling for prevailing TBV deficits, but were not affected by controlling for cardiac contractility levels. Analyses indicated that the TBV deficit explained 91-94% of the group differences in cardiac volume indices. Group differences in cardiac structure were offsetting and, hence, no differences emerged for left ventricular mass index. Therefore the findings indicate that lower cardiac volume levels, displayed primarily by subjects with severe CFS, were not linked to diminished cardiac contractility levels, but were probably a consequence of a co-morbid hypovolaemic condition. Further study is needed to address the extent to which the cardiac and blood volume alterations in CFS have physiological and clinical significance.
[Determination of ventricular volumes by a non-geometric method using gamma-cineangiography].
Faivre, R; Cardot, J C; Baud, M; Verdenet, J; Berthout, P; Bidet, A C; Bassand, J P; Maurat, J P
1985-08-01
The authors suggest a new way of determining ventricular volume by a non-geometric method using gamma-cineangiography. The results obtained by this method were compared with those obtained by a geometric methods and contrast ventriculography in 94 patients. The new non-geometric method supposes that the radioactive tracer is evenly distributed in the cardiovascular system so that blood radioactivity levels can be measured. The ventricular volume is then equal to the ratio of radioactivity in the LV zone to that of 1 ml of blood. Comparison of the radionuclide and angiographic data in the first 60 patients showed systematic values--despite a satisfactory statistical correlation (r = 0.87, y = 0.30 X + 6.3). This underestimation is due to the phenomenon of attenuation related to the depth of the heart in the thoracic cage and to autoabsorption at source, the degree of which depends on the ventricular volume. An empirical method of calculation allows correction for these factors by taking into account absorption in the tissues by relating to body surface area and autoabsorption at source by correcting for the surface of isotopic ventricular projection expressed in pixels. Using the data of this empirical method, the correction formula for radionuclide ventricular volume is obtained by a multiple linear regression: corrected radionuclide volume = K X measured radionuclide volume (Formula: see text). This formula was applied in the following 34 patients. The correlation between the uncorrected and corrected radionuclide volumes and the angiographic volumes was improved (r = 0.65 vs r = 0.94) and the values were more accurate (y = 0.18 X + 26 vs y = 0.96 X + 1.5).(ABSTRACT TRUNCATED AT 250 WORDS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kawaguchi, K.; Sone, T.; Tsuboi, H.
1991-05-01
To test the hypothesis that simultaneous dual energy single photon emission computed tomography (SPECT) with technetium-99m (99mTc) pyrophosphate and thallium-201 (201TI) can provide an accurate estimate of the size of myocardial infarction and to assess the correlation between infarct size and peak serum creatine kinase activity, 165 patients with acute myocardial infarction underwent SPECT 3.2 +/- 1.3 (SD) days after the onset of acute myocardial infarction. In the present study, the difference in the intensity of 99mTc-pyrophosphate accumulation was assumed to be attributable to difference in the volume of infarcted myocardium, and the infarct volume was corrected by the ratiomore » of the myocardial activity to the osseous activity to quantify the intensity of 99mTc-pyrophosphate accumulation. The correlation of measured infarct volume with peak serum creatine kinase activity was significant (r = 0.60, p less than 0.01). There was also a significant linear correlation between the corrected infarct volume and peak serum creatine kinase activity (r = 0.71, p less than 0.01). Subgroup analysis showed a high correlation between corrected volume and peak creatine kinase activity in patients with anterior infarctions (r = 0.75, p less than 0.01) but a poor correlation in patients with inferior or posterior infarctions (r = 0.50, p less than 0.01). In both the early reperfusion and the no reperfusion groups, a good correlation was found between corrected infarct volume and peak serum creatine kinase activity (r = 0.76 and r = 0.76, respectively; p less than 0.01).« less
Ahlgren, André; Wirestam, Ronnie; Petersen, Esben Thade; Ståhlberg, Freddy; Knutsson, Linda
2014-09-01
Quantitative perfusion MRI based on arterial spin labeling (ASL) is hampered by partial volume effects (PVEs), arising due to voxel signal cross-contamination between different compartments. To address this issue, several partial volume correction (PVC) methods have been presented. Most previous methods rely on segmentation of a high-resolution T1 -weighted morphological image volume that is coregistered to the low-resolution ASL data, making the result sensitive to errors in the segmentation and coregistration. In this work, we present a methodology for partial volume estimation and correction, using only low-resolution ASL data acquired with the QUASAR sequence. The methodology consists of a T1 -based segmentation method, with no spatial priors, and a modified PVC method based on linear regression. The presented approach thus avoids prior assumptions about the spatial distribution of brain compartments, while also avoiding coregistration between different image volumes. Simulations based on a digital phantom as well as in vivo measurements in 10 volunteers were used to assess the performance of the proposed segmentation approach. The simulation results indicated that QUASAR data can be used for robust partial volume estimation, and this was confirmed by the in vivo experiments. The proposed PVC method yielded probable perfusion maps, comparable to a reference method based on segmentation of a high-resolution morphological scan. Corrected gray matter (GM) perfusion was 47% higher than uncorrected values, suggesting a significant amount of PVEs in the data. Whereas the reference method failed to completely eliminate the dependence of perfusion estimates on the volume fraction, the novel approach produced GM perfusion values independent of GM volume fraction. The intra-subject coefficient of variation of corrected perfusion values was lowest for the proposed PVC method. As shown in this work, low-resolution partial volume estimation in connection with ASL perfusion estimation is feasible, and provides a promising tool for decoupling perfusion and tissue volume. Copyright © 2014 John Wiley & Sons, Ltd.
Lee, Yoonjung; Chun, Youn-Sic; Kang, Nara; Kim, Minji
2012-12-01
Postsurgical changes of the airway have become a great point of interest and often have been reported to be a predisposing factor for obstructive sleep apnea after mandibular setback surgery. The purpose of this study was to evaluate the 3-dimensional volumetric changes in the upper airway space of patients who underwent bimaxillary surgery to correct Class III malocclusions. This study was performed retrospectively in a group of patients who underwent bimaxillary surgery for Class III malocclusion and had full cone-beam computed tomographic (CBCT) images taken before surgery and 1 day, 3 months, and 6 months after surgery. The upper and lower parts of the airway volume and the diameters of the airway were measured from 2 different levels. Presurgical measurements and the amount of surgical correction were evaluated for their effect on airway volume. Data analyses were performed by analysis of variance and multiple stepwise regression analysis. The subjects included 21 patients (6 men and 15 women; mean age, 22.7 yrs). The surgeries were Le Fort I impaction (5.27 ± 2.58 mm impaction from the posterior nasal spine) and mandibular setback surgery (9.20 ± 4.60 mm set back from the pogonion). No statistically significant differences were found in the total airway volume for all time points. In contrast, the volume of the upper part showed an increase (12.35%) and the lower part showed a decrease (14.07%), with a statistically significant difference 6 months after surgery (P < .05). Predictor variables affecting the upper and lower parts of the airway volume were presurgical A point to Nasion-perpendicular (A to N-perp) and vertical surgical correction of the pogonion and the posterior nasal spine (P < .05). Bimaxillary surgery for the correction of Class III malocclusion affected the morphology by increasing the upper part and decreasing the lower part of the airway, but not the total volume. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Better Assessment of Operational Suitability. Volume 2. Case Studies
1992-01-01
August to 25 October 1988. Although declared operationally effective and suitable by OTEA, a Corrective Action Plan (CAP) was instituted on 5 December 1988...to correct performance deficiencies encountered in FOT&E. The option year 3 procureiaent was exercised on 8 December 1988. An OTEA assessment of the...Hughes developed and tested airframe design modifications to correct deficiencies noted in DT POT I, to improve flight handling characteristics, and to
Palmen, Saskia J M C; Hulshoff Pol, Hilleke E; Kemner, Chantal; Schnack, Hugo G; Durston, Sarah; Lahuis, Bertine E; Kahn, René S; Van Engeland, Herman
2005-04-01
To establish whether high-functioning children with autism spectrum disorder (ASD) have enlarged brains in later childhood, and if so, whether this enlargement is confined to the gray and/or to the white matter and whether it is global or more prominent in specific brain regions. Brain MRI scans were acquired from 21 medication-naive, high-functioning children with ASD between 7 and 15 years of age and 21 comparison subjects matched for gender, age, IQ, height, weight, handedness, and parental education, but not pubertal status. Patients showed a significant increase of 6% in intracranium, total brain, cerebral gray matter, cerebellum, and of more than 40% in lateral and third ventricles compared to controls. The cortical gray-matter volume was evenly affected in all lobes. After correction for brain volume, ventricular volumes remained significantly larger in patients. High-functioning children with ASD showed a global increase in gray-matter, but not white-matter and cerebellar volume, proportional to the increase in brain volume, and a disproportional increase in ventricular volumes, still present after correction for brain volume. Advanced pubertal development in the patients compared to the age-matched controls may have contributed to the findings reported in the present study.
Xu, Lingyu; Xu, Yuancheng; Coulden, Richard; Sonnex, Emer; Hrybouski, Stanislau; Paterson, Ian; Butler, Craig
2018-05-11
Epicardial adipose tissue (EAT) volume derived from contrast enhanced (CE) computed tomography (CT) scans is not well validated. We aim to establish a reliable threshold to accurately quantify EAT volume from CE datasets. We analyzed EAT volume on paired non-contrast (NC) and CE datasets from 25 patients to derive appropriate Hounsfield (HU) cutpoints to equalize two EAT volume estimates. The gold standard threshold (-190HU, -30HU) was used to assess EAT volume on NC datasets. For CE datasets, EAT volumes were estimated using three previously reported thresholds: (-190HU, -30HU), (-190HU, -15HU), (-175HU, -15HU) and were analyzed by a semi-automated 3D Fat analysis software. Subsequently, we applied a threshold correction to (-190HU, -30HU) based on mean differences in radiodensity between NC and CE images (ΔEATrd = CE radiodensity - NC radiodensity). We then validated our findings on EAT threshold in 21 additional patients with paired CT datasets. EAT volume from CE datasets using previously published thresholds consistently underestimated EAT volume from NC dataset standard by a magnitude of 8.2%-19.1%. Using our corrected threshold (-190HU, -3HU) in CE datasets yielded statistically identical EAT volume to NC EAT volume in the validation cohort (186.1 ± 80.3 vs. 185.5 ± 80.1 cm 3 , Δ = 0.6 cm 3 , 0.3%, p = 0.374). Estimating EAT volume from contrast enhanced CT scans using a corrected threshold of -190HU, -3HU provided excellent agreement with EAT volume from non-contrast CT scans using a standard threshold of -190HU, -30HU. Copyright © 2018. Published by Elsevier B.V.
Delay time correction of the gas analyzer in the calculation of anatomical dead space of the lung.
Okubo, T; Shibata, H; Takishima, T
1983-07-01
By means of a mathematical model, we have studied a way to correct the delay time of the gas analyzer in order to calculate the anatomical dead space using Fowler's graphical method. The mathematical model was constructed of ten tubes of equal diameter but unequal length, so that the amount of dead space varied from tube to tube; the tubes were emptied sequentially. The gas analyzer responds with a time lag from the input of the gas signal to the beginning of the response, followed by an exponential response output. The single breath expired volume-concentration relationship was examined with three types of expired flow patterns of which were constant, exponential and sinusoidal. The results indicate that the time correction by the lag time plus time constant of the exponential response of the gas analyzer gives an accurate estimation of anatomical dead space. Time correction less inclusive than this, e.g. lag time only or lag time plus 50% response time, gives an overestimation, and a correction larger than this results in underestimation. The magnitude of error is dependent on the flow pattern and flow rate. The time correction in this study is only for the calculation of dead space, as the corrected volume-concentration curves does not coincide with the true curve. Such correction of the output of the gas analyzer is extremely important when one needs to compare the dead spaces of different gas species at a rather faster flow rate.
[Palliative surgical correction of respiratory insufficiency in diffusive pulmonary emphysema].
Gorbunkov, S D; Varlamov, V V; Cherny, S M; Lukina, O V; Kiryukhina, L D; Romanikhin, A I; Zinchenko, A V; Akopov, A L
To analyze early postoperative period in patients with diffuse pulmonary emphysema after palliative surgical correction of respiratory failure. The study included 196 patients who underwent bullectomy (n=111) and surgical reduction of pulmonary volume (n=85). Overall morbidity and mortality were 40.8% and 12.2% respectively. Among patients older than 60 years these values were significantly higher (58.0% and 22.6% respectively). It was shown that age over 60 years is associated with high risk of complications and mortality after excision of large and giant bulls. In patients <60 years morbidity is comparable after bullectomy and surgical reduction of pulmonary volume. Selection of patients for palliative surgical correction of respiratory failure is generally corresponded to that for lung transplantation. However, these methods should be considered complementary rather competing.
Doctors' confusion over ratios and percentages in drug solutions: the case for standard labelling
Wheeler, Daniel Wren; Remoundos, Dionysios Dennis; Whittlestone, Kim David; Palmer, Michael Ian; Wheeler, Sarah Jane; Ringrose, Timothy Richard; Menon, David Krishna
2004-01-01
The different ways of expressing concentrations of drugs in solution, as ratios or percentages or mass per unit volume, are a potential cause of confusion that may contribute to dose errors. To assess doctors' understanding of what they signify, all active subscribers to doctors.net.uk, an online community exclusively for UK doctors, were invited to complete a brief web-based multiple-choice questionnaire that explored their familiarity with solutions of adrenaline (expressed as a ratio), lidocaine (expressed as a percentage) and atropine (expressed in mg per mL), and their ability to calculate the correct volume to administer in clinical scenarios relevant to all specialties. 2974 (24.6%) replied. The mean score achieved was 4.80 out of 6 (SD 1.38). Only 85.2% and 65.8% correctly identified the mass of drug in the adrenaline and lidocaine solutions, respectively, whilst 93.1% identified the correct concentration of atropine. More would have administered the correct volume of adrenaline and lidocaine in clinical scenarios (89.4% and 81.0%, respectively) but only 65.5% identified the correct volume of atropine. The labelling of drug solutions as ratios or percentages is antiquated and confusing. Labelling should be standardized to mass per unit volume. PMID:15286190
Investigation of brain structure in the 1-month infant.
Dean, Douglas C; Planalp, E M; Wooten, W; Schmidt, C K; Kecskemeti, S R; Frye, C; Schmidt, N L; Goldsmith, H H; Alexander, A L; Davidson, R J
2018-05-01
The developing brain undergoes systematic changes that occur at successive stages of maturation. Deviations from the typical neurodevelopmental trajectory are hypothesized to underlie many early childhood disorders; thus, characterizing the earliest patterns of normative brain development is essential. Recent neuroimaging research provides insight into brain structure during late childhood and adolescence; however, few studies have examined the infant brain, particularly in infants under 3 months of age. Using high-resolution structural MRI, we measured subcortical gray and white matter brain volumes in a cohort (N = 143) of 1-month infants and examined characteristics of these volumetric measures throughout this early period of neurodevelopment. We show that brain volumes undergo age-related changes during the first month of life, with the corresponding patterns of regional asymmetry and sexual dimorphism. Specifically, males have larger total brain volume and volumes differ by sex in regionally specific brain regions, after correcting for total brain volume. Consistent with findings from studies of later childhood and adolescence, subcortical regions appear more rightward asymmetric. Neither sex differences nor regional asymmetries changed with gestation-corrected age. Our results complement a growing body of work investigating the earliest neurobiological changes associated with development and suggest that asymmetry and sexual dimorphism are present at birth.
Measurement of gastric meal and secretion volumes using magnetic resonance imaging
Hoad, C.L.; Parker, H.; Hudders, N.; Costigan, C.; Cox, E.F.; Perkins, A.C.; Blackshaw, P.E.; Marciani, L.; Spiller, R.C.; Fox, M.R.; Gowland, P.A.
2015-01-01
MRI can assess multiple gastric functions without ionizing radiation. However, time consuming image acquisition and analysis of gastric volume data, plus confounding of gastric emptying measurements by gastric secretions mixed with the test meal have limited its use to research centres. This study presents an MRI acquisition protocol and analysis algorithm suitable for the clinical measurement of gastric volume and secretion volume. Reproducibility of gastric volume measurements was assessed using data from 10 healthy volunteers following a liquid test meal with rapid MRI acquisition within one breath-hold and semi-automated analysis. Dilution of the ingested meal with gastric secretion was estimated using a respiratory-triggered T1 mapping protocol. Accuracy of the secretion volume measurements was assessed using data from 24 healthy volunteers following a mixed (liquid/solid) test meal with MRI meal volumes compared to data acquired using gamma scintigraphy (GS) on the same subjects studied on a separate study day. The mean (SD) coefficient of variance between 3 observers for both total gastric contents (including meal, secretions and air) and just the gastric contents (meal and secretion only) was 3 (2) % at large gastric volumes (> 200 ml). Mean (SD) secretion volumes post meal ingestion were 64 (51) ml and 110 (40) ml at 15 and 75 minutes respectively. Comparison with GS meal volumes, showed that MRI meal only volume (after correction for secretion volume) were similar to GS, with a linear regression gradient (std err) of 1.06 (0.10) and intercept −11 (24) ml. In conclusion, (i) rapid acquisition removed the requirement to image during prolonged breath-hold (ii) semi-automatic analysis greatly reduced time required to derive measurements and (iii) correction for secretion volumes provides accurate assessment of gastric meal volumes and emptying. Together these features provide the scientific basis of a protocol which would be suitable in clinical practice. PMID:25592405
Kan, Monica W K; Leung, Lucullus H T; Yu, Peter K N
2013-11-04
A new version of progressive resolution optimizer (PRO) with an option of air cavity correction has been implemented for RapidArc volumetric-modulated arc therapy (RA). The purpose of this study was to compare the performance of this new PRO with the use of air cavity correction option (PRO10_air) against the one without the use of the air cavity correction option (PRO10_no-air) for RapidArc planning in targets with low-density media of different sizes and complexities. The performance of PRO10_no-air and PRO10_air was initially compared using single-arc plans created for four different simple heterogeneous phantoms with virtual targets and organs at risk. Multiple-arc planning of 12 real patients having nasopharyngeal carcinomas (NPC) and ten patients having non-small cell lung cancer (NSCLC) were then performed using the above two options for further comparison. Dose calculations were performed using both the Acuros XB (AXB) algorithm with the dose to medium option and the analytical anisotropic algorithm (AAA). The effect of using intermediate dose option after the first optimization cycle in PRO10_air and PRO10_no-air was also investigated and compared. Plans were evaluated and compared using target dose coverage, critical organ sparing, conformity index, and dose homogeneity index. For NSCLC cases or cases for which large volumes of low-density media were present in or adjacent to the target volume, the use of the air cavity correction option in PRO10 was shown to be beneficial. For NPC cases or cases for which small volumes of both low- and high-density media existed in the target volume, the use of air cavity correction in PRO10 did not improve the plan quality. Based on the AXB dose calculation results, the use of PRO10_air could produce up to 18% less coverage to the bony structures of the planning target volumes for NPC cases. When the intermediate dose option in PRO10 was used, there was negligible difference observed in plan quality between optimizations with and without using the air cavity correction option.
Application and assessment of a robust elastic motion correction algorithm to dynamic MRI.
Herrmann, K-H; Wurdinger, S; Fischer, D R; Krumbein, I; Schmitt, M; Hermosillo, G; Chaudhuri, K; Krishnan, A; Salganicoff, M; Kaiser, W A; Reichenbach, J R
2007-01-01
The purpose of this study was to assess the performance of a new motion correction algorithm. Twenty-five dynamic MR mammography (MRM) data sets and 25 contrast-enhanced three-dimensional peripheral MR angiographic (MRA) data sets which were affected by patient motion of varying severeness were selected retrospectively from routine examinations. Anonymized data were registered by a new experimental elastic motion correction algorithm. The algorithm works by computing a similarity measure for the two volumes that takes into account expected signal changes due to the presence of a contrast agent while penalizing other signal changes caused by patient motion. A conjugate gradient method is used to find the best possible set of motion parameters that maximizes the similarity measures across the entire volume. Images before and after correction were visually evaluated and scored by experienced radiologists with respect to reduction of motion, improvement of image quality, disappearance of existing lesions or creation of artifactual lesions. It was found that the correction improves image quality (76% for MRM and 96% for MRA) and diagnosability (60% for MRM and 96% for MRA).
Accurate Measurement of Small Airways on Low-Dose Thoracic CT Scans in Smokers
Conradi, Susan H.; Atkinson, Jeffrey J.; Zheng, Jie; Schechtman, Kenneth B.; Senior, Robert M.; Gierada, David S.
2013-01-01
Background: Partial volume averaging and tilt relative to the scan plane on transverse images limit the accuracy of airway wall thickness measurements on CT scan, confounding assessment of the relationship between airway remodeling and clinical status in COPD. The purpose of this study was to assess the effect of partial volume averaging and tilt corrections on airway wall thickness measurement accuracy and on relationships between airway wall thickening and clinical status in COPD. Methods: Airway wall thickness measurements in 80 heavy smokers were obtained on transverse images from low-dose CT scan using the open-source program Airway Inspector. Measurements were corrected for partial volume averaging and tilt effects using an attenuation- and geometry-based algorithm and compared with functional status. Results: The algorithm reduced wall thickness measurements of smaller airways to a greater degree than larger airways, increasing the overall range. When restricted to analyses of airways with an inner diameter < 3.0 mm, for a theoretical airway of 2.0 mm inner diameter, the wall thickness decreased from 1.07 ± 0.07 to 0.29 ± 0.10 mm, and the square root of the wall area decreased from 3.34 ± 0.15 to 1.58 ± 0.29 mm, comparable to histologic measurement studies. Corrected measurements had higher correlation with FEV1, differed more between BMI, airflow obstruction, dyspnea, and exercise capacity (BODE) index scores, and explained a greater proportion of FEV1 variability in multivariate models. Conclusions: Correcting for partial volume averaging improves accuracy of airway wall thickness estimation, allowing direct measurement of the small airways to better define their role in COPD. PMID:23172175
2014-01-01
Several morphometric studies have revealed smaller than normal neurons in the neocortex of autistic subjects. To test the hypothesis that abnormal neuronal growth is a marker of an autism-associated global encephalopathy, neuronal volumes were estimated in 16 brain regions, including various subcortical structures, Ammon’s horn, archicortex, cerebellum, and brainstem in 14 brains from individuals with autism 4 to 60 years of age and 14 age-matched control brains. This stereological study showed a significantly smaller volume of neuronal soma in 14 of 16 regions in the 4- to 8-year-old autistic brains than in the controls. Arbitrary classification revealed a very severe neuronal volume deficit in 14.3% of significantly altered structures, severe in 50%, moderate in 21.4%, and mild in 14.3% structures. This pattern suggests desynchronized neuronal growth in the interacting neuronal networks involved in the autistic phenotype. The comparative study of the autistic and control subject brains revealed that the number of structures with a significant volume deficit decreased from 14 in the 4- to 8-year-old autistic subjects to 4 in the 36- to 60-year-old. Neuronal volumes in 75% of the structures examined in the older adults with autism are comparable to neuronal volume in age-matched controls. This pattern suggests defects of neuronal growth in early childhood and delayed up-regulation of neuronal growth during adolescence and adulthood reducing neuron soma volume deficit in majority of examined regions. However, significant correction of neuron size but limited clinical improvements suggests that delayed correction does not restore functional deficits. PMID:24612906
Fallah, Faezeh; Machann, Jürgen; Martirosian, Petros; Bamberg, Fabian; Schick, Fritz; Yang, Bin
2017-04-01
To evaluate and compare conventional T1-weighted 2D turbo spin echo (TSE), T1-weighted 3D volumetric interpolated breath-hold examination (VIBE), and two-point 3D Dixon-VIBE sequences for automatic segmentation of visceral adipose tissue (VAT) volume at 3 Tesla by measuring and compensating for errors arising from intensity nonuniformity (INU) and partial volume effects (PVE). The body trunks of 28 volunteers with body mass index values ranging from 18 to 41.2 kg/m 2 (30.02 ± 6.63 kg/m 2 ) were scanned at 3 Tesla using three imaging techniques. Automatic methods were applied to reduce INU and PVE and to segment VAT. The automatically segmented VAT volumes obtained from all acquisitions were then statistically and objectively evaluated against the manually segmented (reference) VAT volumes. Comparing the reference volumes with the VAT volumes automatically segmented over the uncorrected images showed that INU led to an average relative volume difference of -59.22 ± 11.59, 2.21 ± 47.04, and -43.05 ± 5.01 % for the TSE, VIBE, and Dixon images, respectively, while PVE led to average differences of -34.85 ± 19.85, -15.13 ± 11.04, and -33.79 ± 20.38 %. After signal correction, differences of -2.72 ± 6.60, 34.02 ± 36.99, and -2.23 ± 7.58 % were obtained between the reference and the automatically segmented volumes. A paired-sample two-tailed t test revealed no significant difference between the reference and automatically segmented VAT volumes of the corrected TSE (p = 0.614) and Dixon (p = 0.969) images, but showed a significant VAT overestimation using the corrected VIBE images. Under similar imaging conditions and spatial resolution, automatically segmented VAT volumes obtained from the corrected TSE and Dixon images agreed with each other and with the reference volumes. These results demonstrate the efficacy of the signal correction methods and the similar accuracy of TSE and Dixon imaging for automatic volumetry of VAT at 3 Tesla.
Volume dependence of N-body bound states
NASA Astrophysics Data System (ADS)
König, Sebastian; Lee, Dean
2018-04-01
We derive the finite-volume correction to the binding energy of an N-particle quantum bound state in a cubic periodic volume. Our results are applicable to bound states with arbitrary composition and total angular momentum, and in any number of spatial dimensions. The only assumptions are that the interactions have finite range. The finite-volume correction is a sum of contributions from all possible breakup channels. In the case where the separation is into two bound clusters, our result gives the leading volume dependence up to exponentially small corrections. If the separation is into three or more clusters, there is a power-law factor that is beyond the scope of this work, however our result again determines the leading exponential dependence. We also present two independent methods that use finite-volume data to determine asymptotic normalization coefficients. The coefficients are useful to determine low-energy capture reactions into weakly bound states relevant for nuclear astrophysics. Using the techniques introduced here, one can even extract the infinite-volume energy limit using data from a single-volume calculation. The derived relations are tested using several exactly solvable systems and numerical examples. We anticipate immediate applications to lattice calculations of hadronic, nuclear, and cold atomic systems.
An analysis of the nucleon spectrum from lattice partially-quenched QCD
DOE Office of Scientific and Technical Information (OSTI.GOV)
W. Armour; Allton, C. R.; Leinweber, Derek B.
2010-09-01
The chiral extrapolation of the nucleon mass, Mn, is investigated using data coming from 2-flavour partially-quenched lattice simulations. The leading one-loop corrections to the nucleon mass are derived for partially-quenched QCD. A large sample of lattice results from the CP-PACS Collaboration is analysed, with explicit corrections for finite lattice spacing artifacts. The extrapolation is studied using finite range regularised chiral perturbation theory. The analysis also provides a quantitative estimate of the leading finite volume corrections. It is found that the discretisation, finite-volume and partial quenching effects can all be very well described in this framework, producing an extrapolated value ofmore » Mn in agreement with experiment. This procedure is also compared with extrapolations based on polynomial forms, where the results are less encouraging.« less
Validation of Test Weighing Protocol to Estimate Enteral Feeding Volumes in Preterm Infants.
Rankin, Michael W; Jimenez, Elizabeth Yakes; Caraco, Marina; Collinson, Marie; Lostetter, Lisa; DuPont, Tara L
2016-11-01
To evaluate the accuracy of pre- and postfeeding weights to estimate enteral feeding volumes in preterm infants. Single-center prospective cohort study of infants 28-36 weeks' corrected age receiving gavage feedings. For each test weight, 3 pre- and 3 postgavage feeding weights were obtained by study personnel, blinded to feeding volume, via a specific protocol. The correlation between test weight difference and actual volume ingested was assessed by the use of summary statistics, Spearman rho, and graphical analyses. The relationship between categorical predictive variables and a predefined acceptable difference (±5 mL) was assessed with the χ 2 or Fisher exact test. A total of 101 test weights were performed in 68 infants. Estimated and actual feeding volumes were highly correlated (r = 0.94, P < .001), with a mean absolute difference of 2.95 mL (SD: 2.70; range: 0, 12.3 mL; 5th, 95th percentile: 0, 9.3); 85% of test weights were within ±5 mL of actual feeding volume and did not vary significantly by corrected age, feeding tube or respiratory support type, feeding duration or volume, formula vs breast milk, or caloric density. With adherence to study protocol, 89% of test weights (66/74) were within ±5 mL of actual volume, compared with 71% (19/27, P = .04) when concerns about protocol adherence were noted (eg, difficulty securing oxygen tubing). Via the use of a standard protocol, feeding volumes can be estimated accurately by pre- and postfeeding weights. Test weighing could be a valuable tool to support direct breastfeeding in the neonatal intensive care unit. Copyright © 2016 Elsevier Inc. All rights reserved.
Engelberger, Rolf P; Blazek, Claudia; Amsler, Felix; Keo, Hong H; Baumann, Frédéric; Blättler, Werner; Baumgartner, Iris; Willenberg, Torsten
2011-10-05
Leg edema is a common manifestation of various underlying pathologies. Reliable measurement tools are required to quantify edema and monitor therapeutic interventions. Aim of the present work was to investigate the reproducibility of optoelectronic leg volumetry over 3 weeks' time period and to eliminate daytime related within-individual variability. Optoelectronic leg volumetry was performed in 63 hairdressers (mean age 45 ± 16 years, 85.7% female) in standing position twice within a minute for each leg and repeated after 3 weeks. Both lower leg (legBD) and whole limb (limbBF) volumetry were analysed. Reproducibility was expressed as analytical and within-individual coefficients of variance (CVA, CVW), and as intra-class correlation coefficients (ICC). A total of 492 leg volume measurements were analysed. Both legBD and limbBF volumetry were highly reproducible with CVA of 0.5% and 0.7%, respectively. Within-individual reproducibility of legBD and limbBF volumetry over a three weeks' period was high (CVW 1.3% for both; ICC 0.99 for both). At both visits, the second measurement revealed a significantly higher volume compared to the first measurement with a mean increase of 7.3 ml ± 14.1 (0.33% ± 0.58%) for legBD and 30.1 ml ± 48.5 ml (0.52% ± 0.79%) for limbBF volume. A significant linear correlation between absolute and relative leg volume differences and the difference of exact day time of measurement between the two study visits was found (P < .001). A therefore determined time-correction formula permitted further improvement of CVW. Leg volume changes can be reliably assessed by optoelectronic leg volumetry at a single time point and over a 3 weeks' time period. However, volumetry results are biased by orthostatic and daytime-related volume changes. The bias for day-time related volume changes can be minimized by a time-correction formula.
Nilsson, Markus; Szczepankiewicz, Filip; van Westen, Danielle; Hansson, Oskar
2015-01-01
Conventional motion and eddy-current correction, where each diffusion-weighted volume is registered to a non diffusion-weighted reference, suffers from poor accuracy for high b-value data. An alternative approach is to extrapolate reference volumes from low b-value data. We aim to compare the performance of conventional and extrapolation-based correction of diffusional kurtosis imaging (DKI) data, and to demonstrate the impact of the correction approach on group comparison studies. DKI was performed in patients with Parkinson's disease dementia (PDD), and healthy age-matched controls, using b-values of up to 2750 s/mm2. The accuracy of conventional and extrapolation-based correction methods was investigated. Parameters from DTI and DKI were compared between patients and controls in the cingulum and the anterior thalamic projection tract. Conventional correction resulted in systematic registration errors for high b-value data. The extrapolation-based methods did not exhibit such errors, yielding more accurate tractography and up to 50% lower standard deviation in DKI metrics. Statistically significant differences were found between patients and controls when using the extrapolation-based motion correction that were not detected when using the conventional method. We recommend that conventional motion and eddy-current correction should be abandoned for high b-value data in favour of more accurate methods using extrapolation-based references.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shirley, C.; Pohlmann, K.; Andricevic, R.
1996-09-01
Geological and geophysical data are used with the sequential indicator simulation algorithm of Gomez-Hernandez and Srivastava to produce multiple, equiprobable, three-dimensional maps of informal hydrostratigraphic units at the Frenchman Flat Corrective Action Unit, Nevada Test Site. The upper 50 percent of the Tertiary volcanic lithostratigraphic column comprises the study volume. Semivariograms are modeled from indicator-transformed geophysical tool signals. Each equiprobable study volume is subdivided into discrete classes using the ISIM3D implementation of the sequential indicator simulation algorithm. Hydraulic conductivity is assigned within each class using the sequential Gaussian simulation method of Deutsch and Journel. The resulting maps show the contiguitymore » of high and low hydraulic conductivity regions.« less
Revisiting the Logan plot to account for non-negligible blood volume in brain tissue.
Schain, Martin; Fazio, Patrik; Mrzljak, Ladislav; Amini, Nahid; Al-Tawil, Nabil; Fitzer-Attas, Cheryl; Bronzova, Juliana; Landwehrmeyer, Bernhard; Sampaio, Christina; Halldin, Christer; Varrone, Andrea
2017-08-18
Reference tissue-based quantification of brain PET data does not typically include correction for signal originating from blood vessels, which is known to result in biased outcome measures. The bias extent depends on the amount of radioactivity in the blood vessels. In this study, we seek to revisit the well-established Logan plot and derive alternative formulations that provide estimation of distribution volume ratios (DVRs) that are corrected for the signal originating from the vasculature. New expressions for the Logan plot based on arterial input function and reference tissue were derived, which included explicit terms for whole blood radioactivity. The new methods were evaluated using PET data acquired using [ 11 C]raclopride and [ 18 F]MNI-659. The two-tissue compartment model (2TCM), with which signal originating from blood can be explicitly modeled, was used as a gold standard. DVR values obtained for [ 11 C]raclopride using the either blood-based or reference tissue-based Logan plot were systematically underestimated compared to 2TCM, and for [ 18 F]MNI-659, a proportionality bias was observed, i.e., the bias varied across regions. The biases disappeared when optimal blood-signal correction was used for respective tracer, although for the case of [ 18 F]MNI-659 a small but systematic overestimation of DVR was still observed. The new method appears to remove the bias introduced due to absence of correction for blood volume in regular graphical analysis and can be considered in clinical studies. Further studies are however required to derive a generic mapping between plasma and whole-blood radioactivity levels.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qi, P; Zhuang, T; Magnelli, A
2015-06-15
Purpose It was recommended to use the prescription of 54 Gy/3 with heterogeneity corrections for previously established dose scheme of 60 Gy/3 with homogeneity calculation. This study is to investigate dose coverage for the internal target volume (ITV) with and without heterogeneity correction. Methods Thirty patients who received stereotactic body radiotherapy (SBRT) to a dose of 60 Gy in 3 fractions with homogeneous planning for early stage non-small-cell lung cancer (NSCLC) were selected. ITV was created either from 4DCT scans or a fusion of multi-phase respiratory scans. Planning target volume (PTV) was a 5 mm expansion of the ITV. Formore » this study, we recalculated homogeneous clinical plans using heterogeneity corrections with monitor units set as clinically delivered. All plans were calculated with 3 mm dose grids and collapsed cone convolution algorithm. To account for uncertainties from tumor delineation and image-guided radiotherapy, a structure ITV2mm was created by expanding ITV with 2 mm margins. Dose coverage to the PTV, ITV and ITV2mm were compared with a student paired t-test. Results With heterogeneity corrections, the PTV V60Gy decreased by 10.1% ± 18.4% (p<0.01) while the maximum dose to the PTV increased by 3.7 ± 4.3% (p<0.01). With and without corrections, D99% was 65.8 ± 4.0 Gy and 66.7 ± 4.8 Gy (p=0.15) for the ITV, and 63.9 ± 3.4 Gy and 62.9 ± 4.6 Gy for the ITV2mm (p=0.22), respectively. The mean dose to the ITV and ITV2mm increased 3.6% ± 4.7% (p<0.01) and 2.3% ± 5.2% (p=0.01) with heterogeneity corrections. Conclusion After heterogeneity correction, the peripheral coverage of the PTV decreased to approximately 54 Gy, but D99% of the ITV and ITV2mm was unchanged and the mean dose to the ITV and ITV2mm was increased. Clinical implication of these results requires more investigation.« less
Stefano, A; Gallivanone, F; Messa, C; Gilardi, M C; Gastiglioni, I
2014-12-01
The aim of this work is to evaluate the metabolic impact of Partial Volume Correction (PVC) on the measurement of the Standard Uptake Value (SUV) from [18F]FDG PET-CT oncological studies for treatment monitoring purpose. Twenty-nine breast cancer patients with bone lesions (42 lesions in total) underwent [18F]FDG PET-CT studies after surgical resection of breast cancer primitives, and before (PET-II) chemotherapy and hormone treatment. PVC of bone lesion uptake was performed on the two [18F]FDG PET-CT studies, using a method based on Recovery Coefficients (RC) and on an automatic measurement of lesion metabolic volume. Body-weight average SUV was calculated for each lesion, with and without PVC. The accuracy, reproducibility, clinical feasibility and the metabolic impact on treatment response of the considered PVC method was evaluated. The PVC method was found clinically feasible in bone lesions, with an accuracy of 93% for lesion sphere-equivalent diameter >1 cm. Applying PVC, average SUV values increased, from 7% up to 154% considering both PET-I and PET-II studies, proving the need of the correction. As main finding, PVC modified the therapy response classification in 6 cases according to EORTC 1999 classification and in 5 cases according to PERCIST 1.0 classification. PVC has an important metabolic impact on the assessment of tumor response to treatment by [18F]FDG PET-CT oncological studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Young, Amy V.; Department of Radiation Oncology, St. Luke's-Roosevelt Hospital, New York, NY; Wortham, Angela
2011-03-01
Purpose: Accurate target delineation of the nodal volumes is essential for three-dimensional conformal and intensity-modulated radiotherapy planning for endometrial cancer adjuvant therapy. We hypothesized that atlas-based segmentation ('autocontouring') would lead to time savings and more consistent contours among physicians. Methods and Materials: A reference anatomy atlas was constructed using the data from 15 postoperative endometrial cancer patients by contouring the pelvic nodal clinical target volume on the simulation computed tomography scan according to the Radiation Therapy Oncology Group 0418 trial using commercially available software. On the simulation computed tomography scans from 10 additional endometrial cancer patients, the nodal clinical targetmore » volume autocontours were generated. Three radiation oncologists corrected the autocontours and delineated the manual nodal contours under timed conditions while unaware of the other contours. The time difference was determined, and the overlap of the contours was calculated using Dice's coefficient. Results: For all physicians, manual contouring of the pelvic nodal target volumes and editing the autocontours required a mean {+-} standard deviation of 32 {+-} 9 vs. 23 {+-} 7 minutes, respectively (p = .000001), a 26% time savings. For each physician, the time required to delineate the manual contours vs. correcting the autocontours was 30 {+-} 3 vs. 21 {+-} 5 min (p = .003), 39 {+-} 12 vs. 30 {+-} 5 min (p = .055), and 29 {+-} 5 vs. 20 {+-} 5 min (p = .0002). The mean overlap increased from manual contouring (0.77) to correcting the autocontours (0.79; p = .038). Conclusion: The results of our study have shown that autocontouring leads to increased consistency and time savings when contouring the nodal target volumes for adjuvant treatment of endometrial cancer, although the autocontours still required careful editing to ensure that the lymph nodes at risk of recurrence are properly included in the target volume.« less
NASA Astrophysics Data System (ADS)
Mohammadi, S. M.; Tavakoli-Anbaran, H.; Zeinali, H. Z.
2017-02-01
The parallel-plate free-air ionization chamber termed FAC-IR-300 was designed at the Atomic Energy Organization of Iran, AEOI. This chamber is used for low and medium X-ray dosimetry on the primary standard level. In order to evaluate the air-kerma, some correction factors such as electron-loss correction factor (ke) and photon scattering correction factor (ksc) are needed. ke factor corrects the charge loss from the collecting volume and ksc factor corrects the scattering of photons into collecting volume. In this work ke and ksc were estimated by Monte Carlo simulation. These correction factors are calculated for mono-energy photon. As a result of the simulation data, the ke and ksc values for FAC-IR-300 ionization chamber are 1.0704 and 0.9982, respectively.
Observational constraints on loop quantum cosmology.
Bojowald, Martin; Calcagni, Gianluca; Tsujikawa, Shinji
2011-11-18
In the inflationary scenario of loop quantum cosmology in the presence of inverse-volume corrections, we give analytic formulas for the power spectra of scalar and tensor perturbations convenient to compare with observations. Since inverse-volume corrections can provide strong contributions to the running spectral indices, inclusion of terms higher than the second-order runnings in the power spectra is crucially important. Using the recent data of cosmic microwave background and other cosmological experiments, we place bounds on the quantum corrections.
Torigian, Drew A; Lopez, Rosa Fernandez; Alapati, Sridevi; Bodapati, Geetha; Hofheinz, Frank; van den Hoff, Joerg; Saboury, Babak; Alavi, Abass
2011-01-01
Our aim was to assess feasibility and performance of novel semi-automated image analysis software called ROVER to quantify metabolically active volume (MAV), maximum standardized uptake value-maximum (SUV(max)), 3D partial volume corrected mean SUV (cSUV(mean)), and 3D partial volume corrected mean MVP (cMVP(mean)) of spinal bone marrow metastases on fluorine-18 fluorodeoxyglucose-positron emission tomography/computerized tomography ((18)F-FDG-PET/CT). We retrospectively studied 16 subjects with 31 spinal metastases on FDG-PET/CT and MRI. Manual and ROVER determinations of lesional MAV and SUV(max), and repeated ROVER measurements of MAV, SUV(max), cSUV(mean) and cMVP(mean) were made. Bland-Altman and correlation analyses were performed to assess reproducibility and agreement. Our results showed that analyses of repeated ROVER measurements revealed MAV mean difference (D)=-0.03±0.53cc (95% CI(-0.22, 0.16)), lower limit of agreement (LLOA)=-1.07cc, and upper limit of agreement (ULOA)=1.01cc; SUV(max) D=0.00±0.00 with LOAs=0.00; cSUV(mean) D=-0.01±0.39 (95% CI(-0.15, 0.13)), LLOA=-0.76, and ULOA=0.75; cMVP(mean) D=-0.52±4.78cc (95% CI(-2.23, 1.23)), LLOA=-9.89cc, and ULOA=8.86cc. Comparisons between ROVER and manual measurements revealed volume D= -0.39±1.37cc (95% CI (-0.89, 0.11)), LLOA=-3.08cc, and ULOA=2.30cc; SUV(max) D=0.00±0.00 with LOAs=0.00. Mean percent increase in lesional SUV(mean) and MVP(mean) following partial volume correction using ROVER was 84.25±36.00% and 84.45±35.94% , respectively. In conclusion, it is feasible to estimate MAV, SUV(max), cSUV(mean), and cMVP(mean) of spinal bone marrow metastases from (18)F-FDG-PET/CT quickly and easily with good reproducibility via ROVER software. Partial volume correction is imperative, as uncorrected SUV(mean) and MVP(mean) are significantly underestimated, even for large lesions. This novel approach has great potential for practical, accurate, and precise combined structural-functional PET quantification of disease before and after therapeutic intervention.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Endres, Michael G.; Shindler, Andrea; Tiburzi, Brian C.
The commonly adopted approach for including electromagnetic interactions in lattice QCD simulations relies on using finite volume as the infrared regularization for QED. The long-range nature of the electromagnetic interaction, however, implies that physical quantities are susceptible to power-law finite volume corrections, which must be removed by performing costly simulations at multiple lattice volumes, followed by an extrapolation to the infinite volume limit. In this work, we introduce a photon mass as an alternative means for gaining control over infrared effects associated with electromagnetic interactions. We present findings for hadron mass shifts due to electromagnetic interactions (i.e., for the proton,more » neutron, charged and neutral kaon) and corresponding mass splittings, and compare the results with those obtained from conventional QCD+QED calculations. Results are reported for numerical studies of three flavor electroquenched QCD using ensembles corresponding to 800 MeV pions, ensuring that the only appreciable volume corrections arise from QED effects. The calculations are performed with three lattice volumes with spatial extents ranging from 3.4 - 6.7 fm. As a result, we find that for equal computing time (not including the generation of the lattice configurations), the electromagnetic mass shifts can be extracted from computations on a single (our smallest) lattice volume with comparable or better precision than the conventional approach.« less
Massive photons: An infrared regularization scheme for lattice QCD + QED
Endres, Michael G.; Shindler, Andrea; Tiburzi, Brian C.; ...
2016-08-10
The commonly adopted approach for including electromagnetic interactions in lattice QCD simulations relies on using finite volume as the infrared regularization for QED. The long-range nature of the electromagnetic interaction, however, implies that physical quantities are susceptible to power-law finite volume corrections, which must be removed by performing costly simulations at multiple lattice volumes, followed by an extrapolation to the infinite volume limit. In this work, we introduce a photon mass as an alternative means for gaining control over infrared effects associated with electromagnetic interactions. We present findings for hadron mass shifts due to electromagnetic interactions (i.e., for the proton,more » neutron, charged and neutral kaon) and corresponding mass splittings, and compare the results with those obtained from conventional QCD+QED calculations. Results are reported for numerical studies of three flavor electroquenched QCD using ensembles corresponding to 800 MeV pions, ensuring that the only appreciable volume corrections arise from QED effects. The calculations are performed with three lattice volumes with spatial extents ranging from 3.4 - 6.7 fm. As a result, we find that for equal computing time (not including the generation of the lattice configurations), the electromagnetic mass shifts can be extracted from computations on a single (our smallest) lattice volume with comparable or better precision than the conventional approach.« less
Compulsive sexual behavior: Prefrontal and limbic volume and interactions.
Schmidt, Casper; Morris, Laurel S; Kvamme, Timo L; Hall, Paula; Birchard, Thaddeus; Voon, Valerie
2017-03-01
Compulsive sexual behaviors (CSB) are relatively common and associated with significant personal and social dysfunction. The underlying neurobiology is still poorly understood. The present study examines brain volumes and resting state functional connectivity in CSB compared with matched healthy volunteers (HV). Structural MRI (MPRAGE) data were collected in 92 subjects (23 CSB males and 69 age-matched male HV) and analyzed using voxel-based morphometry. Resting state functional MRI data using multi-echo planar sequence and independent components analysis (ME-ICA) were collected in 68 subjects (23 CSB subjects and 45 age-matched HV). CSB subjects showed greater left amygdala gray matter volumes (small volume corrected, Bonferroni adjusted P < 0.01) and reduced resting state functional connectivity between the left amygdala seed and bilateral dorsolateral prefrontal cortex (whole brain, cluster corrected FWE P < 0.05) compared with HV. CSB is associated with elevated volumes in limbic regions relevant to motivational salience and emotion processing, and impaired functional connectivity between prefrontal control regulatory and limbic regions. Future studies should aim to assess longitudinal measures to investigate whether these findings are risk factors that predate the onset of the behaviors or are consequences of the behaviors. Hum Brain Mapp 38:1182-1190, 2017. © 2016 Wiley Periodicals, Inc. © 2016 The Authors Human Brain Mapping Published by Wiley Periodicals, Inc.
Menger, Richard P; Kalakoti, Piyush; Pugely, Andrew J; Nanda, Anil; Sin, Anthony
2017-10-01
OBJECTIVE Adolescent idiopathic scoliosis (AIS) is the most common form of scoliosis. Limited literature exists defining risk factors associated with outcomes during initial hospitalization in these patients. In this study, the authors investigated patient demographics, clinical and hospital characteristics impacting short-term outcomes, and costs in adolescent patients undergoing surgical deformity correction for idiopathic scoliosis. Additionally, the authors elucidate the impact of hospital surgical volume on outcomes for these patients. METHODS Using the National Inpatient Sample database and appropriate International Classification of Diseases, 9th Revision codes, the authors identified adolescent patients (10-19 years of age) undergoing surgical deformity correction for idiopathic scoliosis during 2001-2014. For national estimates, appropriate weights provided by the Agency of Healthcare Research and Quality were used. Multivariable regression techniques were employed to assess the association of risk factors with discharge disposition, postsurgical neurological complications, length of hospital stay, and hospitalization costs. RESULTS Overall, 75,106 adolescent patients underwent surgical deformity correction. The rates of postsurgical complications were estimated at 0.9% for neurological issues, 2.8% for respiratory complications, 0.8% for cardiac complications, 0.4% for infections, 2.7% for gastrointestinal complications, 0.1% for venous thromboembolic events, and 0.1% for acute renal failure. Overall, patients stayed at the hospital for an average of 5.72 days (median 5 days) and on average incurred hospitalization costs estimated at $54,997 (median $47,909). As compared with patients at low-volume centers (≤ 50 operations/year), those undergoing surgical deformity correction at high-volume centers (> 50/year) had a significantly lower likelihood of an unfavorable discharge (discharge to rehabilitation) (OR 1.16, 95% CI 1.03-1.30, p = 0.016) and incurred lower costs (mean $33,462 vs $56,436, p < 0.001) but had a longer duration of stay (mean 6 vs 5.65 days, p = 0.002). In terms of neurological complications, no significant differences in the odds ratios were noted between high- and low-volume centers (OR 1.23, 95% CI 0.97-1.55, p = 0.091). CONCLUSIONS This study provides insight into the clinical characteristics of AIS patients and their postoperative outcomes following deformity correction as they relate to hospital volume. It provides information regarding independent risk factors for unfavorable discharge and neurological complications following surgery for AIS. The proposed estimates could be used as an adjunct to clinical judgment in presurgical planning, risk stratification, and cost containment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, JY; Hong, DL
Purpose: The purpose of this study is to investigate the patient set-up error and interfraction target coverage in cervical cancer using image-guided adaptive radiotherapy (IGART) with cone-beam computed tomography (CBCT). Methods: Twenty cervical cancer patients undergoing intensity modulated radiotherapy (IMRT) were randomly selected. All patients were matched to the isocenter using laser with the skin markers. Three dimensional CBCT projections were acquired by the Varian Truebeam treatment system. Set-up errors were evaluated by radiation oncologists, after CBCT correction. The clinical target volume (CTV) was delineated on each CBCT, and the planning target volume (PTV) coverage of each CBCT-CTVs was analyzed.more » Results: A total of 152 CBCT scans were acquired from twenty cervical cancer patients, the mean set-up errors in the longitudinal, vertical, and lateral direction were 3.57, 2.74 and 2.5mm respectively, without CBCT corrections. After corrections, these were decreased to 1.83, 1.44 and 0.97mm. For the target coverage, CBCT-CTV coverage without CBCT correction was 94% (143/152), and 98% (149/152) with correction. Conclusion: Use of CBCT verfication to measure patient setup errors could be applied to improve the treatment accuracy. In addition, the set-up error corrections significantly improve the CTV coverage for cervical cancer patients.« less
Lépy, M-C; Altzitzoglou, T; Anagnostakis, M J; Capogni, M; Ceccatelli, A; De Felice, P; Djurasevic, M; Dryak, P; Fazio, A; Ferreux, L; Giampaoli, A; Han, J B; Hurtado, S; Kandic, A; Kanisch, G; Karfopoulos, K L; Klemola, S; Kovar, P; Laubenstein, M; Lee, J H; Lee, J M; Lee, K B; Pierre, S; Carvalhal, G; Sima, O; Tao, Chau Van; Thanh, Tran Thien; Vidmar, T; Vukanac, I; Yang, M J
2012-09-01
The second part of an intercomparison of the coincidence summing correction methods is presented. This exercise concerned three volume sources, filled with liquid radioactive solution. The same experimental spectra, decay scheme and photon emission intensities were used by all the participants. The results were expressed as coincidence summing corrective factors for several energies of (152)Eu and (134)Cs, and different source-to-detector distances. They are presented and discussed. Copyright © 2012 Elsevier Ltd. All rights reserved.
Measurement of gastric meal and secretion volumes using magnetic resonance imaging
NASA Astrophysics Data System (ADS)
Hoad, C. L.; Parker, H.; Hudders, N.; Costigan, C.; Cox, E. F.; Perkins, A. C.; Blackshaw, P. E.; Marciani, L.; Spiller, R. C.; Fox, M. R.; Gowland, P. A.
2015-02-01
MRI can assess multiple gastric functions without ionizing radiation. However, time consuming image acquisition and analysis of gastric volume data, plus confounding of gastric emptying measurements by gastric secretions mixed with the test meal have limited its use to research centres. This study presents an MRI acquisition protocol and analysis algorithm suitable for the clinical measurement of gastric volume and secretion volume. Reproducibility of gastric volume measurements was assessed using data from 10 healthy volunteers following a liquid test meal with rapid MRI acquisition within one breath-hold and semi-automated analysis. Dilution of the ingested meal with gastric secretion was estimated using a respiratory-triggered T1 mapping protocol. Accuracy of the secretion volume measurements was assessed using data from 24 healthy volunteers following a mixed (liquid/solid) test meal with MRI meal volumes compared to data acquired using gamma scintigraphy (GS) on the same subjects studied on a separate study day. The mean ± SD coefficient of variance between 3 observers for both total gastric contents (including meal, secretions and air) and just the gastric contents (meal and secretion only) was 3 ± 2% at large gastric volumes (>200 ml). Mean ± SD secretion volumes post meal ingestion were 64 ± 51 ml and 110 ± 40 ml at 15 and 75 min, respectively. Comparison with GS meal volumes, showed that MRI meal only volume (after correction for secretion volume) were similar to GS, with a linear regression gradient ± std err of 1.06 ± 0.10 and intercept -11 ± 24 ml. In conclusion, (i) rapid volume acquisition and respiratory triggered T1 mapping removed the requirement to image during prolonged breath-holds (ii) semi-automatic analysis greatly reduced the time required to derive measurements and (iii) correction for secretion volumes provided accurate assessment of gastric meal volumes and emptying. Together these features provide the scientific basis of a protocol which would be suitable in clinical practice.
Sergiievskyi, Volodymyr P; Jeanmairet, Guillaume; Levesque, Maximilien; Borgis, Daniel
2014-06-05
Molecular density functional theory (MDFT) offers an efficient implicit-solvent method to estimate molecule solvation free-energies, whereas conserving a fully molecular representation of the solvent. Even within a second-order approximation for the free-energy functional, the so-called homogeneous reference fluid approximation, we show that the hydration free-energies computed for a data set of 500 organic compounds are of similar quality as those obtained from molecular dynamics free-energy perturbation simulations, with a computer cost reduced by 2-3 orders of magnitude. This requires to introduce the proper partial volume correction to transform the results from the grand canonical to the isobaric-isotherm ensemble that is pertinent to experiments. We show that this correction can be extended to 3D-RISM calculations, giving a sound theoretical justification to empirical partial molar volume corrections that have been proposed recently.
Automated measurements for individualized heart rate correction of the QT interval.
Mason, Jay W; Moon, Thomas E
2015-04-01
Subject-specific electrocardiographic QT interval correction for heart rate is often used in clinical trials with frequent electrocardiographic recordings. However, in these studies relatively few 10-s, 12-lead electrocardiograms may be available for calculating the individual correction. Highly automated QT and RR measurement tools have made it practical to measure electrocardiographic intervals on large volumes of continuous electrocardiogram data. The purpose of this study was to determine whether an automated method can be used in lieu of a manual method. In 49 subjects who completed all treatments in a four-armed crossover study we compared two methods for derivation of individualized rate-correction coefficients: manual measurement on 10-s electrocardiograms and automated measurement of QT and RR during continuous 24-h electrocardiogram recordings. The four treatments, received by each subject in a latin-square randomization sequence were placebo, moxifloxacin, and two doses of an investigational drug. Analysis of continuous electrocardiogram data yielded a lower standard deviation of QT:RR regression values than the manual method, though the differences were not statistically significant. The within-subject and within-treatment coefficients of variation between the manual and automated methods were not significantly different. Corrected QT values from the two methods had similar rates of true and false positive identification of moxifloxacin's QT prolonging effect. An automated method for individualized rate correction applied to continuous electrocardiogram data could be advantageous in clinical trials, as the automated method is simpler, is based upon a much larger volume of data, yields similar results, and requires no human over-reading of the measurements. © The Author(s) 2015.
TH-A-9A-03: Dosimetric Effect of Rotational Errors for Lung Stereotactic Body Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, J; Kim, H; Park, J
2014-06-15
Purpose: To evaluate the dosimetric effects on target volume and organs at risk (OARs) due to roll rotational errors in treatment setup of stereotactic body radiation therapy (SBRT) for lung cancer. Methods: There were a total of 23 volumetric modulated arc therapy (VMAT) plans for lung SBRT examined in this retrospective study. Each CT image of VMAT plans was intentionally rotated by ±1°, ±2°, and ±3° to simulate roll rotational setup errors. The axis of rotation was set at the center of T-spine. The target volume and OARs in the rotated CT images were re-defined by deformable registration of originalmore » contours. The dose distributions on each set of rotated images were re-calculated to cover the planning target volume (PTV) with the prescription dose before and after the couch translational correction. The dose-volumetric changes of PTVs and spinal cords were analyzed. Results: The differences in D95% of PTVs by −3°, −2°, −1°, 1°, 2°, and 3° roll rotations before the couch translational correction were on average −11.3±11.4%, −5.46±7.24%, −1.11±1.38% −3.34±3.97%, −9.64±10.3%, and −16.3±14.7%, respectively. After the couch translational correction, those values were −0.195±0.544%, −0.159±0.391%, −0.188±0.262%, −0.310±0.270%, −0.407±0.331%, and −0.433±0.401%, respectively. The maximum dose difference of spinal cord among the 23 plans even after the couch translational correction was 25.9% at −3° rotation. Conclusions: Roll rotational setup errors in lung SBRT significantly influenced the coverage of target volume using VMAT technique. This could be in part compensated by the translational couch correction. However, in spite of the translational correction, the delivered doses to the spinal cord could be more than the calculated doses. Therefore if rotational setup errors exist during lung SBRT using VMAT technique, the rotational correction would rather be considered to prevent over-irradiation of normal tissues than the translational correction.« less
Cross, Russell; Olivieri, Laura; O'Brien, Kendall; Kellman, Peter; Xue, Hui; Hansen, Michael
2016-02-25
Traditional cine imaging for cardiac functional assessment requires breath-holding, which can be problematic in some situations. Free-breathing techniques have relied on multiple averages or real-time imaging, producing images that can be spatially and/or temporally blurred. To overcome this, methods have been developed to acquire real-time images over multiple cardiac cycles, which are subsequently motion corrected and reformatted to yield a single image series displaying one cardiac cycle with high temporal and spatial resolution. Application of these algorithms has required significant additional reconstruction time. The use of distributed computing was recently proposed as a way to improve clinical workflow with such algorithms. In this study, we have deployed a distributed computing version of motion corrected re-binning reconstruction for free-breathing evaluation of cardiac function. Twenty five patients and 25 volunteers underwent cardiovascular magnetic resonance (CMR) for evaluation of left ventricular end-systolic volume (ESV), end-diastolic volume (EDV), and end-diastolic mass. Measurements using motion corrected re-binning were compared to those using breath-held SSFP and to free-breathing SSFP with multiple averages, and were performed by two independent observers. Pearson correlation coefficients and Bland-Altman plots tested agreement across techniques. Concordance correlation coefficient and Bland-Altman analysis tested inter-observer variability. Total scan plus reconstruction times were tested for significant differences using paired t-test. Measured volumes and mass obtained by motion corrected re-binning and by averaged free-breathing SSFP compared favorably to those obtained by breath-held SSFP (r = 0.9863/0.9813 for EDV, 0.9550/0.9685 for ESV, 0.9952/0.9771 for mass). Inter-observer variability was good with concordance correlation coefficients between observers across all acquisition types suggesting substantial agreement. Both motion corrected re-binning and averaged free-breathing SSFP acquisition and reconstruction times were shorter than breath-held SSFP techniques (p < 0.0001). On average, motion corrected re-binning required 3 min less than breath-held SSFP imaging, a 37% reduction in acquisition and reconstruction time. The motion corrected re-binning image reconstruction technique provides robust cardiac imaging that can be used for quantification that compares favorably to breath-held SSFP as well as multiple average free-breathing SSFP, but can be obtained in a fraction of the time when using cloud-based distributed computing reconstruction.
40 CFR 1065.695 - Data requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... restriction. (v) Charge air cooler volume. (vi) Charge air cooler outlet temperature, specified engine... following: (i) Drift correction. (ii) Noise correction. (iii) “Dry-to-wet” correction. (iv) NMHC, CH4, and...
40 CFR 1065.695 - Data requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... restriction. (v) Charge air cooler volume. (vi) Charge air cooler outlet temperature, specified engine... following: (i) Drift correction. (ii) Noise correction. (iii) “Dry-to-wet” correction. (iv) NMHC, CH4, and...
40 CFR 1065.695 - Data requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... restriction. (v) Charge air cooler volume. (vi) Charge air cooler outlet temperature, specified engine... following: (i) Drift correction. (ii) Noise correction. (iii) “Dry-to-wet” correction. (iv) NMHC, CH4, and...
Arnold, J B; Liow, J S; Schaper, K A; Stern, J J; Sled, J G; Shattuck, D W; Worth, A J; Cohen, M S; Leahy, R M; Mazziotta, J C; Rottenberg, D A
2001-05-01
The desire to correct intensity nonuniformity in magnetic resonance images has led to the proliferation of nonuniformity-correction (NUC) algorithms with different theoretical underpinnings. In order to provide end users with a rational basis for selecting a given algorithm for a specific neuroscientific application, we evaluated the performance of six NUC algorithms. We used simulated and real MRI data volumes, including six repeat scans of the same subject, in order to rank the accuracy, precision, and stability of the nonuniformity corrections. We also compared algorithms using data volumes from different subjects and different (1.5T and 3.0T) MRI scanners in order to relate differences in algorithmic performance to intersubject variability and/or differences in scanner performance. In phantom studies, the correlation of the extracted with the applied nonuniformity was highest in the transaxial (left-to-right) direction and lowest in the axial (top-to-bottom) direction. Two of the six algorithms demonstrated a high degree of stability, as measured by the iterative application of the algorithm to its corrected output. While none of the algorithms performed ideally under all circumstances, locally adaptive methods generally outperformed nonadaptive methods. Copyright 2001 Academic Press.
Barbee, David L; Flynn, Ryan T; Holden, James E; Nickles, Robert J; Jeraj, Robert
2010-01-01
Tumor heterogeneities observed in positron emission tomography (PET) imaging are frequently compromised of partial volume effects which may affect treatment prognosis, assessment, or future implementations such as biologically optimized treatment planning (dose painting). This paper presents a method for partial volume correction of PET-imaged heterogeneous tumors. A point source was scanned on a GE Discover LS at positions of increasing radii from the scanner’s center to obtain the spatially varying point spread function (PSF). PSF images were fit in three dimensions to Gaussian distributions using least squares optimization. Continuous expressions were devised for each Gaussian width as a function of radial distance, allowing for generation of the system PSF at any position in space. A spatially varying partial volume correction (SV-PVC) technique was developed using expectation maximization (EM) and a stopping criterion based on the method’s correction matrix generated for each iteration. The SV-PVC was validated using a standard tumor phantom and a tumor heterogeneity phantom, and was applied to a heterogeneous patient tumor. SV-PVC results were compared to results obtained from spatially invariant partial volume correction (SINV-PVC), which used directionally uniform three dimensional kernels. SV-PVC of the standard tumor phantom increased the maximum observed sphere activity by 55 and 40% for 10 and 13 mm diameter spheres, respectively. Tumor heterogeneity phantom results demonstrated that as net changes in the EM correction matrix decreased below 35%, further iterations improved overall quantitative accuracy by less than 1%. SV-PVC of clinically observed tumors frequently exhibited changes of ±30% in regions of heterogeneity. The SV-PVC method implemented spatially varying kernel widths and automatically determined the number of iterations for optimal restoration, parameters which are arbitrarily chosen in SINV-PVC. Comparing SV-PVC to SINV-PVC demonstrated that similar results could be reached using both methods, but large differences result for the arbitrary selection of SINV-PVC parameters. The presented SV-PVC method was performed without user intervention, requiring only a tumor mask as input. Research involving PET-imaged tumor heterogeneity should include correcting for partial volume effects to improve the quantitative accuracy of results. PMID:20009194
Numerical investigation of finite-volume effects for the HVP
NASA Astrophysics Data System (ADS)
Boyle, Peter; Gülpers, Vera; Harrison, James; Jüttner, Andreas; Portelli, Antonin; Sachrajda, Christopher
2018-03-01
It is important to correct for finite-volume (FV) effects in the presence of QED, since these effects are typically large due to the long range of the electromagnetic interaction. We recently made the first lattice calculation of electromagnetic corrections to the hadronic vacuum polarisation (HVP). For the HVP, an analytical derivation of FV corrections involves a two-loop calculation which has not yet been carried out. We instead calculate the universal FV corrections numerically, using lattice scalar QED as an effective theory. We show that this method gives agreement with known analytical results for scalar mass FV effects, before applying it to calculate FV corrections for the HVP. This method for numerical calculation of FV effects is also widely applicable to quantities beyond the HVP.
Loop quantum corrected Einstein Yang-Mills black holes
NASA Astrophysics Data System (ADS)
Protter, Mason; DeBenedictis, Andrew
2018-05-01
In this paper, we study the homogeneous interiors of black holes possessing SU(2) Yang-Mills fields subject to corrections inspired by loop quantum gravity. The systems studied possess both magnetic and induced electric Yang-Mills fields. We consider the system of equations both with and without Wilson loop corrections to the Yang-Mills potential. The structure of the Yang-Mills Hamiltonian, along with the restriction to homogeneity, allows for an anomaly-free effective quantization. In particular, we study the bounce which replaces the classical singularity and the behavior of the Yang-Mills fields in the quantum corrected interior, which possesses topology R ×S2 . Beyond the bounce, the magnitude of the Yang-Mills electric field asymptotically grows monotonically. This results in an ever-expanding R sector even though the two-sphere volume is asymptotically constant. The results are similar with and without Wilson loop corrections on the Yang-Mills potential.
Leung, Lucullus H.T.; Yu, Peter K.N.
2013-01-01
A new version of progressive resolution optimizer (PRO) with an option of air cavity correction has been implemented for RapidArc volumetric‐modulated arc therapy (RA). The purpose of this study was to compare the performance of this new PRO with the use of air cavity correction option (PRO10_air) against the one without the use of the air cavity correction option (PRO10_no‐air) for RapidArc planning in targets with low‐density media of different sizes and complexities. The performance of PRO10_no‐air and PRO10_air was initially compared using single‐arc plans created for four different simple heterogeneous phantoms with virtual targets and organs at risk. Multiple‐arc planning of 12 real patients having nasopharyngeal carcinomas (NPC) and ten patients having non‐small cell lung cancer (NSCLC) were then performed using the above two options for further comparison. Dose calculations were performed using both the Acuros XB (AXB) algorithm with the dose to medium option and the analytical anisotropic algorithm (AAA). The effect of using intermediate dose option after the first optimization cycle in PRO10_air and PRO10_no‐air was also investigated and compared. Plans were evaluated and compared using target dose coverage, critical organ sparing, conformity index, and dose homogeneity index. For NSCLC cases or cases for which large volumes of low‐density media were present in or adjacent to the target volume, the use of the air cavity correction option in PROIO was shown to be beneficial. For NPC cases or cases for which small volumes of both low‐ and high‐density media existed in the target volume, the use of air cavity correction in PRO10 did not improve the plan quality. Based on the AXB dose calculation results, the use of PRO10_air could produce up to 18% less coverage to the bony structures of the planning target volumes for NPC cases. When the intermediate dose option in PRO10 was used, there was negligible difference observed in plan quality between optimizations with and without using the air cavity correction option. PACS number: 87.55.D‐, 87.55.de, 87.56.N‐
Pulmonary function tests correlated with thoracic volumes in adolescent idiopathic scoliosis.
Ledonio, Charles Gerald T; Rosenstein, Benjamin E; Johnston, Charles E; Regelmann, Warren E; Nuckley, David J; Polly, David W
2017-01-01
Scoliosis deformity has been linked with deleterious changes in the thoracic cavity that affect pulmonary function. The causal relationship between spinal deformity and pulmonary function has yet to be fully defined. It has been hypothesized that deformity correction improves pulmonary function by restoring both respiratory muscle efficiency and increasing the space available to the lungs. This research aims to correlate pulmonary function and thoracic volume before and after scoliosis correction. Retrospective correlational analysis between thoracic volume modeling from plain x-rays and pulmonary function tests was conducted. Adolescent idiopathic scoliosis patients enrolled in a multicenter database were sorted by pre-operative Total Lung Capacities (TLC) % predicted values from their Pulmonary Function Tests (PFT). Ten patients with the best and ten patients with the worst TLC values were included. Modeled thoracic volume and TLC values were compared before and 2 years after surgery. Scoliosis correction resulted in an increase in the thoracic volume for patients with the worst initial TLCs (11.7%) and those with the best initial TLCs (12.5%). The adolescents with the most severe pulmonary restriction prior to surgery strongly correlated with post-operative change in total lung capacity and thoracic volume (r 2 = 0.839; p < 0.001). The mean increase in thoracic volume in this group was 373.1 cm 3 (11.7%) which correlated with a 21.2% improvement in TLC. Scoliosis correction in adolescents was found to increase thoracic volume and is strongly correlated with improved TLC in cases with severe restrictive pulmonary function, but no correlation was found in cases with normal pulmonary function. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:175-182, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Impact of reconstruction parameters on quantitative I-131 SPECT
NASA Astrophysics Data System (ADS)
van Gils, C. A. J.; Beijst, C.; van Rooij, R.; de Jong, H. W. A. M.
2016-07-01
Radioiodine therapy using I-131 is widely used for treatment of thyroid disease or neuroendocrine tumors. Monitoring treatment by accurate dosimetry requires quantitative imaging. The high energy photons however render quantitative SPECT reconstruction challenging, potentially requiring accurate correction for scatter and collimator effects. The goal of this work is to assess the effectiveness of various correction methods on these effects using phantom studies. A SPECT/CT acquisition of the NEMA IEC body phantom was performed. Images were reconstructed using the following parameters: (1) without scatter correction, (2) with triple energy window (TEW) scatter correction and (3) with Monte Carlo-based scatter correction. For modelling the collimator-detector response (CDR), both (a) geometric Gaussian CDRs as well as (b) Monte Carlo simulated CDRs were compared. Quantitative accuracy, contrast to noise ratios and recovery coefficients were calculated, as well as the background variability and the residual count error in the lung insert. The Monte Carlo scatter corrected reconstruction method was shown to be intrinsically quantitative, requiring no experimentally acquired calibration factor. It resulted in a more accurate quantification of the background compartment activity density compared with TEW or no scatter correction. The quantification error relative to a dose calibrator derived measurement was found to be <1%,-26% and 33%, respectively. The adverse effects of partial volume were significantly smaller with the Monte Carlo simulated CDR correction compared with geometric Gaussian or no CDR modelling. Scatter correction showed a small effect on quantification of small volumes. When using a weighting factor, TEW correction was comparable to Monte Carlo reconstruction in all measured parameters, although this approach is clinically impractical since this factor may be patient dependent. Monte Carlo based scatter correction including accurately simulated CDR modelling is the most robust and reliable method to reconstruct accurate quantitative iodine-131 SPECT images.
Greve, Douglas N; Salat, David H; Bowen, Spencer L; Izquierdo-Garcia, David; Schultz, Aaron P; Catana, Ciprian; Becker, J Alex; Svarer, Claus; Knudsen, Gitte M; Sperling, Reisa A; Johnson, Keith A
2016-05-15
A cross-sectional group study of the effects of aging on brain metabolism as measured with (18)F-FDG-PET was performed using several different partial volume correction (PVC) methods: no correction (NoPVC), Meltzer (MZ), Müller-Gärtner (MG), and the symmetric geometric transfer matrix (SGTM) using 99 subjects aged 65-87years from the Harvard Aging Brain study. Sensitivity to parameter selection was tested for MZ and MG. The various methods and parameter settings resulted in an extremely wide range of conclusions as to the effects of age on metabolism, from almost no changes to virtually all of cortical regions showing a decrease with age. Simulations showed that NoPVC had significant bias that made the age effect on metabolism appear to be much larger and more significant than it is. MZ was found to be the same as NoPVC for liberal brain masks; for conservative brain masks, MZ showed few areas correlated with age. MG and SGTM were found to be similar; however, MG was sensitive to a thresholding parameter that can result in data loss. CSF uptake was surprisingly high at about 15% of that in gray matter. The exclusion of CSF from SGTM and MG models, which is almost universally done, caused a substantial loss in the power to detect age-related changes. This diversity of results reflects the literature on the metabolism of aging and suggests that extreme care should be taken when applying PVC or interpreting results that have been corrected for partial volume effects. Using the SGTM, significant age-related changes of about 7% per decade were found in frontal and cingulate cortices as well as primary visual and insular cortices. Copyright © 2016 Elsevier Inc. All rights reserved.
Greve, Douglas N.; Salat, David H.; Bowen, Spencer L.; Izquierdo-Garcia, David; Schultz, Aaron P.; Catana, Ciprian; Becker, J. Alex; Svarer, Claus; Knudsen, Gitte; Sperling, Reisa A.; Johnson, Keith A.
2016-01-01
A cross-sectional group study of the effects of aging on brain metabolism as measured with 18F-FDG PET was performed using several different partial volume correction (PVC) methods: no correction (NoPVC), Meltzer (MZ), Müller-Gärtner (MG), and the symmetric geometric transfer matrix (SGTM) using 99 subjects aged 65-87 from the Harvard Aging Brain study. Sensitivity to parameter selection was tested for MZ and MG. The various methods and parameter settings resulted in an extremely wide range of conclusions as to the effects of age on metabolism, from almost no changes to virtually all of cortical regions showing a decrease with age. Simulations showed that NoPVC had significant bias that made the age effect on metabolism appear to be much larger and more significant than it is. MZ was found to be the same as NoPVC for liberal brain masks; for conservative brain masks, MZ showed few areas correlated with age. MG and SGTM were found to be similar; however, MG was sensitive to a thresholding parameter that can result in data loss. CSF uptake was surprisingly high at about 15% of that in gray matter. Exclusion of CSF from SGTM and MG models, which is almost universally done, caused a substantial loss in the power to detect age-related changes. This diversity of results reflects the literature on the metabolism of aging and suggests that extreme care should be taken when applying PVC or interpreting results that have been corrected for partial volume effects. Using the SGTM, significant age-related changes of about 7% per decade were found in frontal and cingulate cortices as well as primary visual and insular cortices. PMID:26915497
Lei, Yu; Wu, Qiuwen
2010-04-21
Offline adaptive radiotherapy (ART) has been used to effectively correct and compensate for prostate motion and reduce the required margin. The efficacy depends on the characteristics of the patient setup error and interfraction motion through the whole treatment; specifically, systematic errors are corrected and random errors are compensated for through the margins. In online image-guided radiation therapy (IGRT) of prostate cancer, the translational setup error and inter-fractional prostate motion are corrected through pre-treatment imaging and couch correction at each fraction. However, the rotation and deformation of the target are not corrected and only accounted for with margins in treatment planning. The purpose of this study was to investigate whether the offline ART strategy is necessary for an online IGRT protocol and to evaluate the benefit of the hybrid strategy. First, to investigate the rationale of the hybrid strategy, 592 cone-beam-computed tomography (CBCT) images taken before and after each fraction for an online IGRT protocol from 16 patients were analyzed. Specifically, the characteristics of prostate rotation were analyzed. It was found that there exist systematic inter-fractional prostate rotations, and they are patient specific. These rotations, if not corrected, are persistent through the treatment fraction, and rotations detected in early fractions are representative of those in later fractions. These findings suggest that the offline adaptive replanning strategy is beneficial to the online IGRT protocol with further margin reductions. Second, to quantitatively evaluate the benefit of the hybrid strategy, 412 repeated helical CT scans from 25 patients during the course of treatment were included in the replanning study. Both low-risk patients (LRP, clinical target volume, CTV = prostate) and intermediate-risk patients (IRP, CTV = prostate + seminal vesicles) were included in the simulation. The contours of prostate and seminal vesicles were delineated on each CT. The benefit of margin reduction to compensate for both rotation and deformation in the hybrid strategy was evaluated geometrically. With the hybrid strategy, the planning margins can be reduced by 1.4 mm for LRP, and 2.0 mm for IRP, compared with the standard online IGRT only, to maintain the same 99% target volume coverage. The average relative reduction in planning target volume (PTV) based on the internal target volume (ITV) from PTV based on CTV is 19% for LRP, and 27% for IRP.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kazakia,G.; Burghardt, A.; Cheung, S.
2008-01-01
Assessment of bone tissue mineral density (TMD) may provide information critical to the understanding of mineralization processes and bone biomechanics. High-resolution three-dimensional assessment of TMD has recently been demonstrated using synchrotron radiation microcomputed tomography (SR{mu}CT); however, this imaging modality is relatively inaccessible due to the scarcity of SR facilities. Conventional desktop {mu}CT systems are widely available and have been used extensively to assess bone microarchitecture. However, the polychromatic source and cone-shaped beam geometry complicate assessment of TMD by conventional {mu}CT. The goal of this study was to evaluate {mu}CT-based measurement of degree and distribution of tissue mineralization in a quantitative,more » spatially resolved manner. Specifically, {mu}CT measures of bone mineral content (BMC) and TMD were compared to those obtained by SR{mu}CT and gravimetric methods. Cylinders of trabecular bone were machined from human femoral heads (n=5), vertebrae (n=5), and proximal tibiae (n=4). Cylinders were imaged in saline on a polychromatic {mu}CT system at an isotropic voxel size of 8 {mu}m. Volumes were reconstructed using beam hardening correction algorithms based on hydroxyapatite (HA)-resin wedge phantoms of 200 and 1200 mgHA/cm3. SR{mu}CT imaging was performed at an isotropic voxel size of 7.50 {mu}m at the National Synchrotron Light Source. Attenuation values were converted to HA concentration using a linear regression derived by imaging a calibration phantom. Architecture and mineralization parameters were calculated from the image data. Specimens were processed using gravimetric methods to determine ash mass and density. {mu}CT-based BMC values were not affected by altering the beam hardening correction. Volume-averaged TMD values calculated by the two corrections were significantly different (p=0.008) in high volume fraction specimens only, with the 1200 mgHA/cm3 correction resulting in a 4.7% higher TMD value. {mu}CT and SR{mu}CT provided significantly different measurements of both BMC and TMD (p<0.05). In high volume fraction specimens, {mu}CT with 1200 mgHA/cm3 correction resulted in BMC and TMD values 16.7% and 15.0% lower, respectively, than SR{mu}CT values. In low volume fraction specimens, {mu}CT with 1200 mgHA/cm3 correction resulted in BMC and TMD values 12.8% and 12.9% lower, respectively, than SR{mu}CT values. {mu}CT and SR{mu}CT values were well-correlated when volume fraction groups were considered individually (BMC R2=0.97-1.00; TMD R2=0.78-0.99). Ash mass and density were higher than the SR{mu}CT equivalents by 8.6% in high volume fraction specimens and 10.9% in low volume fraction specimens (p<0.05). BMC values calculated by tomography were highly correlated with ash mass (ash versus {mu}CT R2=0.96-1.00; ash versus SR{mu}CT R2=0.99-1.00). TMD values calculated by tomography were moderately correlated with ash density (ash versus {mu}CT R2=0.64-0.72; ash versus SR{mu}CT R2=0.64). Spatially resolved comparisons highlighted substantial geometric nonuniformity in the {mu}CT data, which were reduced (but not eliminated) using the 1200 mg HA/cm3 beam hardening correction, and did not exist in the SR{mu}CT data. This study represents the first quantitative comparison of {mu}CT mineralization evaluation against SR{mu}CT and gravimetry. Our results indicate that {mu}CT mineralization measures are underestimated but well-correlated with SR{mu}CT and gravimetric data, particularly when volume fraction groups are considered individually.« less
Kazakia, G. J.; Burghardt, A. J.; Cheung, S.; Majumdar, S.
2008-01-01
Assessment of bone tissue mineral density (TMD) may provide information critical to the understanding of mineralization processes and bone biomechanics. High-resolution three-dimensional assessment of TMD has recently been demonstrated using synchrotron radiation microcomputed tomography (SRμCT); however, this imaging modality is relatively inaccessible due to the scarcity of SR facilities. Conventional desktop μCT systems are widely available and have been used extensively to assess bone microarchitecture. However, the polychromatic source and cone-shaped beam geometry complicate assessment of TMD by conventional μCT. The goal of this study was to evaluate μCT-based measurement of degree and distribution of tissue mineralization in a quantitative, spatially resolved manner. Specifically, μCT measures of bone mineral content (BMC) and TMD were compared to those obtained by SRμCT and gravimetric methods. Cylinders of trabecular bone were machined from human femoral heads (n=5), vertebrae (n=5), and proximal tibiae (n=4). Cylinders were imaged in saline on a polychromatic μCT system at an isotropic voxel size of 8 μm. Volumes were reconstructed using beam hardening correction algorithms based on hydroxyapatite (HA)-resin wedge phantoms of 200 and 1200 mg HA∕cm3. SRμCT imaging was performed at an isotropic voxel size of 7.50 μm at the National Synchrotron Light Source. Attenuation values were converted to HA concentration using a linear regression derived by imaging a calibration phantom. Architecture and mineralization parameters were calculated from the image data. Specimens were processed using gravimetric methods to determine ash mass and density. μCT-based BMC values were not affected by altering the beam hardening correction. Volume-averaged TMD values calculated by the two corrections were significantly different (p=0.008) in high volume fraction specimens only, with the 1200 mg HA∕cm3 correction resulting in a 4.7% higher TMD value. μCT and SRμCT provided significantly different measurements of both BMC and TMD (p<0.05). In high volume fraction specimens, μCT with 1200 mg HA∕cm3 correction resulted in BMC and TMD values 16.7% and 15.0% lower, respectively, than SRμCT values. In low volume fraction specimens, μCT with 1200 mg HA∕cm3 correction resulted in BMC and TMD values 12.8% and 12.9% lower, respectively, than SRμCT values. μCT and SRμCT values were well-correlated when volume fraction groups were considered individually (BMC R2=0.97−1.00; TMD R2=0.78−0.99). Ash mass and density were higher than the SRμCT equivalents by 8.6% in high volume fraction specimens and 10.9% in low volume fraction specimens (p<0.05). BMC values calculated by tomography were highly correlated with ash mass (ash versus μCT R2=0.96−1.00; ash versus SRμCT R2=0.99−1.00). TMD values calculated by tomography were moderately correlated with ash density (ash versus μCT R2=0.64−0.72; ash versus SRμCT R2=0.64). Spatially resolved comparisons highlighted substantial geometric nonuniformity in the μCT data, which were reduced (but not eliminated) using the 1200 mg HA∕cm3 beam hardening correction, and did not exist in the SRμCT data. This study represents the first quantitative comparison of μCT mineralization evaluation against SRμCT and gravimetry. Our results indicate that μCT mineralization measures are underestimated but well-correlated with SRμCT and gravimetric data, particularly when volume fraction groups are considered individually. PMID:18697542
Nugent, Scott; Castellano, Christian-Alexandre; Goffaux, Philippe; Whittingstall, Kevin; Lepage, Martin; Paquet, Nancy; Bocti, Christian; Fulop, Tamas; Cunnane, Stephen C
2014-06-01
Several studies have suggested that glucose hypometabolism may be present in specific brain regions in cognitively normal older adults and could contribute to the risk of subsequent cognitive decline. However, certain methodological shortcomings, including a lack of partial volume effect (PVE) correction or insufficient cognitive testing, confound the interpretation of most studies on this topic. We combined [(18)F]fluorodeoxyglucose ([(18)F]FDG) positron emission tomography (PET) and magnetic resonance (MR) imaging to quantify cerebral metabolic rate of glucose (CMRg) as well as cortical volume and thickness in 43 anatomically defined brain regions from a group of cognitively normal younger (25 ± 3 yr old; n = 25) and older adults (71 ± 9 yr old; n = 31). After correcting for PVE, we observed 11-17% lower CMRg in three specific brain regions of the older group: the superior frontal cortex, the caudal middle frontal cortex, and the caudate (P ≤ 0.01 false discovery rate-corrected). In the older group, cortical volumes and cortical thickness were 13-33 and 7-18% lower, respectively, in multiple brain regions (P ≤ 0.01 FDR correction). There were no differences in CMRg between individuals who were or were not prescribed antihypertensive medication. There were no significant correlations between CMRg and cognitive performance or metabolic parameters measured in fasting plasma. We conclude that highly localized glucose hypometabolism and widespread cortical thinning and atrophy can be present in older adults who are cognitively normal, as assessed using age-normed neuropsychological testing measures. Copyright © 2014 the American Physiological Society.
NASA Astrophysics Data System (ADS)
Rotenberg, David J.
Artifacts caused by head motion are a substantial source of error in fMRI that limits its use in neuroscience research and clinical settings. Real-time scan-plane correction by optical tracking has been shown to correct slice misalignment and non-linear spin-history artifacts, however residual artifacts due to dynamic magnetic field non-uniformity may remain in the data. A recently developed correction technique, PLACE, can correct for absolute geometric distortion using the complex image data from two EPI images, with slightly shifted k-space trajectories. We present a correction approach that integrates PLACE into a real-time scan-plane update system by optical tracking, applied to a tissue-equivalent phantom undergoing complex motion and an fMRI finger tapping experiment with overt head motion to induce dynamic field non-uniformity. Experiments suggest that including volume by volume geometric distortion correction by PLACE can suppress dynamic geometric distortion artifacts in a phantom and in vivo and provide more robust activation maps.
White Matter Volume Predicts Language Development in Congenital Heart Disease
Rollins, Caitlin K.; Asaro, Lisa A.; Akhondi-Asl, Alireza; Kussman, Barry D.; Rivkin, Michael J.; Bellinger, David C.; Warfield, Simon K.; Wypij, David; Newburger, Jane W.; Soul, Janet S.
2016-01-01
Objective To determine whether brain volume is reduced at one year and whether these volumes are associated with neurodevelopment in biventricular congenital heart disease (CHD) repaired in infancy. Study design Infants with biventricular CHD (n = 48) underwent brain magnetic resonance imaging (MRI) and neurodevelopmental testing with the Bayley Scales of Infant Development-II (BSID-II) and the MacArthur-Bates Communicative Development Inventories (CDI) at one year. A multi-template based probabilistic segmentation algorithm was applied to volumetric MRI data. We compared volumes with those of 13 healthy control infants of comparable ages. In the CHD group, we measured Spearman correlations between neurodevelopmental outcomes and the residuals from linear regression of the volumes on corrected chronological age at MRI and sex. Results Compared with controls, CHD infant had reductions of 54 mL in total brain (P = 0.009), 40 mL in cerebral white matter (P < 0.001), and 1.2 mL in brainstem (P = 0.003) volumes. Within the CHD group, brain volumes were not correlated with BSID-II scores but did correlate positively with CDI language development. Conclusion Infants with biventricular CHD show total brain volume reductions at one year of age, driven by differences in cerebral white matter. White matter volume correlates with language development, but not broader developmental indices. These findings suggest that abnormalities in white matter development detected months after corrective heart surgery may contribute to language impairment. Trial registration ClinicalTrials.gov: NCT00006183 PMID:27837950
Eddy current correction in volume-localized MR spectroscopy
NASA Technical Reports Server (NTRS)
Lin, C.; Wendt, R. E. 3rd; Evans, H. J.; Rowe, R. M.; Hedrick, T. D.; LeBlanc, A. D.
1994-01-01
The quality of volume-localized magnetic resonance spectroscopy is affected by eddy currents caused by gradient switching. Eddy currents can be reduced with improved gradient systems; however, it has been suggested that the distortion due to eddy currents can be compensated for during postprocessing with a single-frequency reference signal. The authors propose modifying current techniques for acquiring the single-frequency reference signal by using relaxation weighting to reduce interference from components that cannot be eliminated by digital filtering alone. Additional sequences with T1 or T2 weighting for reference signal acquisition are shown to have the same eddy current characteristics as the original signal without relaxation weighting. The authors also studied a new eddy current correction method that does not require a single-frequency reference signal. This method uses two free induction decays (FIDs) collected from the same volume with two sequences with opposite gradients. Phase errors caused by eddy currents are opposite in these two FIDs and can be canceled completely by combining the FIDs. These methods were tested in a phantom. Eddy current distortions were corrected, allowing quantitative measurement of structures such as the -CH = CH- component, which is otherwise undetectable.
The human hippocampus is not sexually-dimorphic: Meta-analysis of structural MRI volumes.
Tan, Anh; Ma, Wenli; Vira, Amit; Marwha, Dhruv; Eliot, Lise
2016-01-01
Hippocampal atrophy is found in many psychiatric disorders that are more prevalent in women. Sex differences in memory and spatial skills further suggest that males and females differ in hippocampal structure and function. We conducted the first meta-analysis of male-female difference in hippocampal volume (HCV) based on published MRI studies of healthy participants of all ages, to test whether the structure is reliably sexually dimorphic. Using four search strategies, we collected 68 matched samples of males' and females' uncorrected HCVs (in 4418 total participants), and 36 samples of male and female HCVs (2183 participants) that were corrected for individual differences in total brain volume (TBV) or intracranial volume (ICV). Pooled effect sizes were calculated using a random-effects model for left, right, and bilateral uncorrected HCVs and for left and right HCVs corrected for TBV or ICV. We found that uncorrected HCV was reliably larger in males, with Hedges' g values of 0.545 for left hippocampus, 0.526 for right hippocampus, and 0.557 for bilateral hippocampus. Meta-regression revealed no effect of age on the sex difference in left, right, or bilateral HCV. In the subset of studies that reported it, both TBV (g=1.085) and ICV (g=1.272) were considerably larger in males. Accordingly, studies reporting HCVs corrected for individual differences in TBV or ICV revealed no significant sex differences in left and right HCVs (Hedges' g ranging from +0.011 to -0.206). In summary, we found that human males of all ages exhibit a larger HCV than females, but adjusting for individual differences in TBV or ICV results in no reliable sex difference. The frequent claim that women have a disproportionately larger hippocampus than men was not supported. Copyright © 2015 Elsevier Inc. All rights reserved.
Lang, Xu; Li, Huabing; Qin, Wen; Yu, Chunshui
2014-01-01
Investigations on hippocampal and amygdalar volume have revealed inconsistent results in patients with posttraumatic stress disorder (PTSD). Little is known about the structural covariance alterations between the hippocampus and amygdala in PTSD. In this study, we evaluated the alteration in the hippocampal and amygdalar volume and their structural covariance in the coal mine gas explosion related PTSD. High resolution T1-weighted magnetic resonance imaging (MRI) was performed on coal mine gas explosion related PTSD male patients (n = 14) and non-traumatized coalminers without PTSD (n = 25). The voxel-based morphometry (VBM) method was used to test the inter-group differences in hippocampal and amygdalar volume as well as the inter-group differences in structural covariance between the ipsilateral hippocampus and amygdala. PTSD patients exhibited decreased gray matter volume (GMV) in the bilateral hippocampi compared to controls (p<0.05, FDR corrected). GMV covariances between the ipsilateral hippocampus and amygdala were significantly reduced in PTSD patients compared with controls (p<0.05, FDR corrected). The coalminers with gas explosion related PTSD had decreased hippocampal volume and structural covariance with the ipsilateral amygdala, suggesting that the structural impairment of the hippocampus may implicate in the pathophysiology of PTSD. PMID:25000505
2014-01-01
Background Many pathologies seen in the preterm population are associated with abnormal blood supply, yet robust evaluation of preterm cardiac function is scarce and consequently normative ranges in this population are limited. The aim of this study was to quantify and validate left ventricular dimension and function in preterm infants using cardiovascular magnetic resonance (CMR). An initial investigation of the impact of the common congenital defect patent ductus arteriosus (PDA) was then carried out. Methods Steady State Free Procession short axis stacks were acquired. Normative ranges of left ventricular end diastolic volume (EDV), stroke volume (SV), left ventricular output (LVO), ejection fraction (EF), left ventricular (LV) mass, wall thickness and fractional thickening were determined in “healthy” (control) neonates. Left ventricular parameters were then investigated in PDA infants. Unpaired student t-tests compared the 2 groups. Multiple linear regression analysis assessed impact of shunt volume in PDA infants, p-value ≤ 0.05 being significant. Results 29 control infants median (range) corrected gestational age at scan 34+6(31+1-39+3) weeks were scanned. EDV, SV, LVO, LV mass normalized by weight and EF were shown to decrease with increasing corrected gestational age (cGA) in controls. In 16 PDA infants (cGA 30+3(27+3-36+1) weeks) left ventricular dimension and output were significantly increased, yet there was no significant difference in ejection fraction and fractional thickening between the two groups. A significant association between shunt volume and increased left ventricular mass correcting for postnatal age and corrected gestational age existed. Conclusion CMR assessment of left ventricular function has been validated in neonates, providing more robust normative ranges of left ventricular dimension and function in this population. Initial investigation of PDA infants would suggest that function is relatively maintained. PMID:25160730
Two-compartment modeling of tissue microcirculation revisited.
Brix, Gunnar; Salehi Ravesh, Mona; Griebel, Jürgen
2017-05-01
Conventional two-compartment modeling of tissue microcirculation is used for tracer kinetic analysis of dynamic contrast-enhanced (DCE) computed tomography or magnetic resonance imaging studies although it is well-known that the underlying assumption of an instantaneous mixing of the administered contrast agent (CA) in capillaries is far from being realistic. It was thus the aim of the present study to provide theoretical and computational evidence in favor of a conceptually alternative modeling approach that makes it possible to characterize the bias inherent to compartment modeling and, moreover, to approximately correct for it. Starting from a two-region distributed-parameter model that accounts for spatial gradients in CA concentrations within blood-tissue exchange units, a modified lumped two-compartment exchange model was derived. It has the same analytical structure as the conventional two-compartment model, but indicates that the apparent blood flow identifiable from measured DCE data is substantially overestimated, whereas the three other model parameters (i.e., the permeability-surface area product as well as the volume fractions of the plasma and interstitial distribution space) are unbiased. Furthermore, a simple formula was derived to approximately compute a bias-corrected flow from the estimates of the apparent flow and permeability-surface area product obtained by model fitting. To evaluate the accuracy of the proposed modeling and bias correction method, representative noise-free DCE curves were analyzed. They were simulated for 36 microcirculation and four input scenarios by an axially distributed reference model. As analytically proven, the considered two-compartment exchange model is structurally identifiable from tissue residue data. The apparent flow values estimated for the 144 simulated tissue/input scenarios were considerably biased. After bias-correction, the deviations between estimated and actual parameter values were (11.2 ± 6.4) % (vs. (105 ± 21) % without correction) for the flow, (3.6 ± 6.1) % for the permeability-surface area product, (5.8 ± 4.9) % for the vascular volume and (2.5 ± 4.1) % for the interstitial volume; with individual deviations of more than 20% being the exception and just marginal. Increasing the duration of CA administration only had a statistically significant but opposite effect on the accuracy of the estimated flow (declined) and intravascular volume (improved). Physiologically well-defined tissue parameters are structurally identifiable and accurately estimable from DCE data by the conceptually modified two-compartment model in combination with the bias correction. The accuracy of the bias-corrected flow is nearly comparable to that of the three other (theoretically unbiased) model parameters. As compared to conventional two-compartment modeling, this feature constitutes a major advantage for tracer kinetic analysis of both preclinical and clinical DCE imaging studies. © 2017 American Association of Physicists in Medicine.
Finite-volume effects and the electromagnetic contributions to kaon and pion masses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Basak, Subhasish; Bazavov, Alexei; Bernard, Claude
2014-09-25
We report on the MILC Collaboration calculation of electromagnetic effects on light pseudoscalar mesons. The simulations employ asqtad staggered dynamical quarks in QCD plus quenched photons, with lattice spacings varying from 0.12 to 0.06 fm. Finite volume corrections for the MILC realization of lattice electrodynamics have been calculated in chiral perturbation theory and applied to the lattice data. These corrections differ from those calculated by Hayakawa and Uno because our treatment of zero modes differs from theirs. Updated results for the corrections to "Dashen's theorem" are presented.
No, Yeon A; Ahn, Byeong Heon; Kim, Beom Joon; Kim, Myeung Nam; Hong, Chang Kwon
2016-01-01
For correction of this asymmetrical hypertrophy, botulinum toxin type A (BTxA) injection is one of convenient treatment modalities. Unfortunately, physical examination of masseter muscle is not enough to estimate the exact volume of muscle hypertrophy difference. Two Koreans, male and female, of bilateral masseter hypertrophy with asymmetricity were evaluated. BTxA (NABOTA(®), Daewoong, Co. Ltd., Seoul, Korea) was injected at master muscle site with total 50 U (25 U at each side) and volume change was evaluated with three-dimensional (3D) CT image analysis. Maximum reduction of masseter hypertrophy was recognized at 2-month follow-up and reduced muscle size started to restore after 3 months. Mean reduction of masseter muscle volume was 36% compared with baseline. More hypertrophied side of masseter muscle presented 42% of volume reduction at 2-month follow-up but less hypertrophied side of masseter muscle showed 30% of volume shrinkage. In conclusion, 3D CT image analysis might be the exact evaluation tool for correction of asymmetrical masseter hypertrophy by botulinum toxin injection.
Spatiotemporal alignment of in utero BOLD-MRI series.
Turk, Esra Abaci; Luo, Jie; Gagoski, Borjan; Pascau, Javier; Bibbo, Carolina; Robinson, Julian N; Grant, P Ellen; Adalsteinsson, Elfar; Golland, Polina; Malpica, Norberto
2017-08-01
To present a method for spatiotemporal alignment of in-utero magnetic resonance imaging (MRI) time series acquired during maternal hyperoxia for enabling improved quantitative tracking of blood oxygen level-dependent (BOLD) signal changes that characterize oxygen transport through the placenta to fetal organs. The proposed pipeline for spatiotemporal alignment of images acquired with a single-shot gradient echo echo-planar imaging includes 1) signal nonuniformity correction, 2) intravolume motion correction based on nonrigid registration, 3) correction of motion and nonrigid deformations across volumes, and 4) detection of the outlier volumes to be discarded from subsequent analysis. BOLD MRI time series collected from 10 pregnant women during 3T scans were analyzed using this pipeline. To assess pipeline performance, signal fluctuations between consecutive timepoints were examined. In addition, volume overlap and distance between manual region of interest (ROI) delineations in a subset of frames and the delineations obtained through propagation of the ROIs from the reference frame were used to quantify alignment accuracy. A previously demonstrated rigid registration approach was used for comparison. The proposed pipeline improved anatomical alignment of placenta and fetal organs over the state-of-the-art rigid motion correction methods. In particular, unexpected temporal signal fluctuations during the first normoxia period were significantly decreased (P < 0.01) and volume overlap and distance between region boundaries measures were significantly improved (P < 0.01). The proposed approach to align MRI time series enables more accurate quantitative studies of placental function by improving spatiotemporal alignment across placenta and fetal organs. 1 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:403-412. © 2017 International Society for Magnetic Resonance in Medicine.
Beyer, Thomas; Lassen, Martin L; Boellaard, Ronald; Delso, Gaspar; Yaqub, Maqsood; Sattler, Bernhard; Quick, Harald H
2016-02-01
We assess inter- and intra-subject variability of magnetic resonance (MR)-based attenuation maps (MRμMaps) of human subjects for state-of-the-art positron emission tomography (PET)/MR imaging systems. Four healthy male subjects underwent repeated MR imaging with a Siemens Biograph mMR, Philips Ingenuity TF and GE SIGNA PET/MR system using product-specific MR sequences and image processing algorithms for generating MRμMaps. Total lung volumes and mean attenuation values in nine thoracic reference regions were calculated. Linear regression was used for comparing lung volumes on MRμMaps. Intra- and inter-system variability was investigated using a mixed effects model. Intra-system variability was seen for the lung volume of some subjects, (p = 0.29). Mean attenuation values across subjects were significantly different (p < 0.001) due to different segmentations of the trachea. Differences in the attenuation values caused noticeable intra-individual and inter-system differences that translated into a subsequent bias of the corrected PET activity values, as verified by independent simulations. Significant differences of MRμMaps generated for the same subjects but different PET/MR systems resulted in differences in attenuation correction factors, particularly in the thorax. These differences currently limit the quantitative use of PET/MR in multi-center imaging studies.
Cosmological perturbations in teleparallel Loop Quantum Cosmology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haro, Jaime, E-mail: jaime.haro@upc.edu
2013-11-01
Cosmological perturbations in Loop Quantum Cosmology (LQC) are usually studied incorporating either holonomy corrections, where the Ashtekar connection is replaced by a suitable sinus function in order to have a well-defined quantum analogue, or inverse-volume corrections coming from the eigenvalues of the inverse-volume operator. In this paper we will develop an alternative approach to calculate cosmological perturbations in LQC based on the fact that, holonomy corrected LQC in the flat Friedmann-Lemaître-Robertson-Walker (FLRW) geometry could be also obtained as a particular case of teleparallel F(T) gravity (teleparallel LQC). The main idea of our approach is to mix the simple bounce providedmore » by holonomy corrections in LQC with the non-singular perturbation equations given by F(T) gravity, in order to obtain a matter bounce scenario as a viable alternative to slow-roll inflation. In our study, we have obtained an scale invariant power spectrum of cosmological perturbations. However, the ratio of tensor to scalar perturbations is of order 1, which does not agree with the current observations. For this reason, we suggest a model where a transition from the matter domination to a quasi de Sitter phase is produced in order to enhance the scalar power spectrum.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, S; Robinson, A; Kiess, A
2015-06-15
Purpose: The purpose of this study is to develop an accurate and effective technique to predict and monitor volume changes of the tumor and organs at risk (OARs) from daily cone-beam CTs (CBCTs). Methods: While CBCT is typically used to minimize the patient setup error, its poor image quality impedes accurate monitoring of daily anatomical changes in radiotherapy. Reconstruction artifacts in CBCT often cause undesirable errors in registration-based contour propagation from the planning CT, a conventional way to estimate anatomical changes. To improve the registration and segmentation accuracy, we developed a new deformable image registration (DIR) that iteratively corrects CBCTmore » intensities using slice-based histogram matching during the registration process. Three popular DIR algorithms (hierarchical B-spline, demons, optical flow) augmented by the intensity correction were implemented on a graphics processing unit for efficient computation, and their performances were evaluated on six head and neck (HN) cancer cases. Four trained scientists manually contoured nodal gross tumor volume (GTV) on the planning CT and every other fraction CBCTs for each case, to which the propagated GTV contours by DIR were compared. The performance was also compared with commercial software, VelocityAI (Varian Medical Systems Inc.). Results: Manual contouring showed significant variations, [-76, +141]% from the mean of all four sets of contours. The volume differences (mean±std in cc) between the average manual segmentation and four automatic segmentations are 3.70±2.30(B-spline), 1.25±1.78(demons), 0.93±1.14(optical flow), and 4.39±3.86 (VelocityAI). In comparison to the average volume of the manual segmentations, the proposed approach significantly reduced the estimation error by 9%(B-spline), 38%(demons), and 51%(optical flow) over the conventional mutual information based method (VelocityAI). Conclusion: The proposed CT-CBCT registration with local CBCT intensity correction can accurately predict the tumor volume change with reduced errors. Although demonstrated only on HN nodal GTVs, the results imply improved accuracy for other critical structures. This work was supported by NIH/NCI under grant R42CA137886.« less
Effect of provider volume on the accuracy of hospital report cards: a Monte Carlo study.
Austin, Peter C; Reeves, Mathew J
2014-03-01
Hospital report cards, in which outcomes after the provision of medical or surgical care are compared across healthcare providers, are being published with increasing frequency. However, the accuracy of such comparisons is controversial, especially when case volumes are small. The objective was to determine the relationship between hospital case volume and the accuracy of hospital report cards. Monte Carlo simulations were used to examine the influence of hospital case volume on the accuracy of hospital report cards in a setting in which true hospital performance was known with certainty, and perfect risk-adjustment was feasible. The parameters used to generate the simulated data sets were obtained from empirical analyses of data on patients hospitalized with acute myocardial infarction in Ontario, Canada, in which the overall 30-day mortality rate was 11.1%. We found that provider volume had a strong effect on the accuracy of hospital report cards. However, provider volume had to be >300 before ≥70% of hospitals were correctly classified. Furthermore, hospital volume had to be >1000 before ≥80% of hospitals were correctly classified. Producers and users of hospital report cards need to be aware that, even when perfect risk adjustment is possible, the accuracy of hospital report cards is, at best, modest for small to medium-sized case loads (i.e., 100-300). Hospital report cards displayed high degrees of accuracy only when provider volumes exceeded the typical annual hospital case load for many cardiovascular conditions and procedures.
Evaluation of simulation-based scatter correction for 3-D PET cardiac imaging
NASA Astrophysics Data System (ADS)
Watson, C. C.; Newport, D.; Casey, M. E.; deKemp, R. A.; Beanlands, R. S.; Schmand, M.
1997-02-01
Quantitative imaging of the human thorax poses one of the most difficult challenges for three-dimensional (3-D) (septaless) positron emission tomography (PET), due to the strong attenuation of the annihilation radiation and the large contribution of scattered photons to the data. In [/sup 18/F] fluorodeoxyglucose (FDG) studies of the heart with the patient's arms in the field of view, the contribution of scattered events can exceed 50% of the total detected coincidences. Accurate correction for this scatter component is necessary for meaningful quantitative image analysis and tracer kinetic modeling. For this reason, the authors have implemented a single-scatter simulation technique for scatter correction in positron volume imaging. Here, they describe this algorithm and present scatter correction results from human and chest phantom studies.
NASA Astrophysics Data System (ADS)
Jentzen, Walter
2010-04-01
The use of recovery coefficients (RCs) in 124I PET lesion imaging is a simple method to correct the imaged activity concentration (AC) primarily for the partial-volume effect and, to a minor extent, for the prompt gamma coincidence effect. The aim of this phantom study was to experimentally investigate a number of various factors affecting the 124I RCs. Three RC-based correction approaches were considered. These approaches differ with respect to the volume of interest (VOI) drawn, which determines the imaged AC and the RCs: a single voxel VOI containing the maximum value (maximum RC), a spherical VOI with a diameter of the scanner resolution (resolution RC) and a VOI equaling the physical object volume (isovolume RC). Measurements were performed using mainly a stand-alone PET scanner (EXACT HR+) and a latest-generation PET/CT scanner (BIOGRAPH mCT). The RCs were determined using a cylindrical phantom containing spheres or rotational ellipsoids and were derived from images acquired with a reference acquisition protocol. For each type of RC, the influence of the following factors on the RC was assessed: object shape, background activity spill in and iterative image reconstruction parameters. To evaluate the robustness of the RC-based correction approaches, the percentage deviation between RC-corrected and true ACs was determined from images acquired with a clinical acquisition protocol of different AC regimes. The observed results of the shape and spill-in effects were compared with simulation data derived from a convolution-based model. The study demonstrated that the shape effect was negligible and, therefore, was in agreement with theoretical expectations. In contradiction to the simulation results, the observed spill-in effect was unexpectedly small. To avoid variations in the determination of RCs due to reconstruction parameter changes, image reconstruction with a pixel length of about one-third or less of the scanner resolution and an OSEM 1 × 32 algorithm or one with somewhat higher number of effective iterations are recommended. Using the clinical acquisition protocol, the phantom study indicated that the resolution- or isovolume-based recovery-correction approaches appeared to be more appropriate to recover the ACs from patient data; however, the application of the three RC-based correction approaches to small lesions containing low ACs was, in particular, associated with large underestimations. The phantom study had several limitations, which were discussed in detail.
Nketiah, Gabriel; Selnaes, Kirsten M; Sandsmark, Elise; Teruel, Jose R; Krüger-Stokke, Brage; Bertilsson, Helena; Bathen, Tone F; Elschot, Mattijs
2018-05-01
To evaluate the effect of correction for B 0 inhomogeneity-induced geometric distortion in echo-planar diffusion-weighted imaging on quantitative apparent diffusion coefficient (ADC) analysis in multiparametric prostate MRI. Geometric distortion correction was performed in echo-planar diffusion-weighted images (b = 0, 50, 400, 800 s/mm 2 ) of 28 patients, using two b 0 scans with opposing phase-encoding polarities. Histology-matched tumor and healthy tissue volumes of interest delineated on T 2 -weighted images were mapped to the nondistortion-corrected and distortion-corrected data sets by resampling with and without spatial coregistration. The ADC values were calculated on the volume and voxel level. The effect of distortion correction on ADC quantification and tissue classification was evaluated using linear-mixed models and logistic regression, respectively. Without coregistration, the absolute differences in tumor ADC (range: 0.0002-0.189 mm 2 /s×10 -3 (volume level); 0.014-0.493 mm 2 /s×10 -3 (voxel level)) between the nondistortion-corrected and distortion-corrected were significantly associated (P < 0.05) with distortion distance (mean: 1.4 ± 1.3 mm; range: 0.3-5.3 mm). No significant associations were found upon coregistration; however, in patients with high rectal gas residue, distortion correction resulted in improved spatial representation and significantly better classification of healthy versus tumor voxels (P < 0.05). Geometric distortion correction in DWI could improve quantitative ADC analysis in multiparametric prostate MRI. Magn Reson Med 79:2524-2532, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Dorin, Thomas; Donnadieu, Patricia; Chaix, Jean-Marc; Lefebvre, Williams; Geuser, Frédéric De; Deschamps, Alexis
2015-11-01
Transmission Electron Microscopy (TEM) can be used to measure the size distribution and volume fraction of fine scale precipitates in metallic systems. However, such measurements suffer from a number of artefacts that need to be accounted for, related to the finite thickness of the TEM foil and to the projected observation in two dimensions of the microstructure. We present a correction procedure to describe the 3D distribution of disc-like particles and apply this method to the plate-like T1 precipitates in an Al-Li-Cu alloy in two ageing conditions showing different particle morphologies. The precipitates were imaged in a High-Angular Annular Dark Field Microscope (HAADF-STEM). The corrected size distribution is further used to determine the precipitate volume fraction. Atom probe tomography (APT) is finally utilised as an alternative way to measure the precipitate volume fraction and test the validity of the electron microscopy results. Copyright © 2015 Elsevier Ltd. All rights reserved.
Measurement of lung volumes from supine portable chest radiographs.
Ries, A L; Clausen, J L; Friedman, P J
1979-12-01
Lung volumes in supine nonambulatory patients are physiological parameters often difficult to measure with current techniques (plethysmograph, gas dilution). Existing radiographic methods for measuring lung volumes require standard upright chest radiographs. Accordingly, in 31 normal supine adults, we determined helium-dilution functional residual and total lung capacities and measured planimetric lung field areas (LFA) from corresponding portable anteroposterior and lateral radiographs. Low radiation dose methods, which delivered less than 10% of that from standard portable X-ray technique, were utilized. Correlation between lung volume and radiographic LFA was highly significant (r = 0.96, SEE = 10.6%). Multiple-step regressions using height and chest diameter correction factors reduced variance, but weight and radiographic magnification factors did not. In 17 additional subjects studied for validation, the regression equations accurately predicted radiographic lung volume. Thus, this technique can provide accurate and rapid measurement of lung volume in studies involving supine patients.
Ruscher-Hill, Brandi; Kirkham, Amy L.; Burns, Jennifer M.
2018-01-01
Body mass dynamics of animals can indicate critical associations between extrinsic factors and population vital rates. Photogrammetry can be used to estimate mass of individuals in species whose life histories make it logistically difficult to obtain direct body mass measurements. Such studies typically use equations to relate volume estimates from photogrammetry to mass; however, most fail to identify the sources of error between the estimated and actual mass. Our objective was to identify the sources of error that prevent photogrammetric mass estimation from directly predicting actual mass, and develop a methodology to correct this issue. To do this, we obtained mass, body measurements, and scaled photos for 56 sedated Weddell seals (Leptonychotes weddellii). After creating a three-dimensional silhouette in the image processing program PhotoModeler Pro, we used horizontal scale bars to define the ground plane, then removed the below-ground portion of the animal’s estimated silhouette. We then re-calculated body volume and applied an expected density to estimate animal mass. We compared the body mass estimates derived from this silhouette slice method with estimates derived from two other published methodologies: body mass calculated using photogrammetry coupled with a species-specific correction factor, and estimates using elliptical cones and measured tissue densities. The estimated mass values (mean ± standard deviation 345±71 kg for correction equation, 346±75 kg for silhouette slice, 343±76 kg for cones) were not statistically distinguishable from each other or from actual mass (346±73 kg) (ANOVA with Tukey HSD post-hoc, p>0.05 for all pairwise comparisons). We conclude that volume overestimates from photogrammetry are likely due to the inability of photo modeling software to properly render the ventral surface of the animal where it contacts the ground. Due to logistical differences between the “correction equation”, “silhouette slicing”, and “cones” approaches, researchers may find one technique more useful for certain study programs. In combination or exclusively, these three-dimensional mass estimation techniques have great utility in field studies with repeated measures sampling designs or where logistic constraints preclude weighing animals. PMID:29320573
Late-Onset Alzheimer's Disease Polygenic Risk Profile Score Predicts Hippocampal Function.
Xiao, Ena; Chen, Qiang; Goldman, Aaron L; Tan, Hao Yang; Healy, Kaitlin; Zoltick, Brad; Das, Saumitra; Kolachana, Bhaskar; Callicott, Joseph H; Dickinson, Dwight; Berman, Karen F; Weinberger, Daniel R; Mattay, Venkata S
2017-11-01
We explored the cumulative effect of several late-onset Alzheimer's disease (LOAD) risk loci using a polygenic risk profile score (RPS) approach on measures of hippocampal function, cognition, and brain morphometry. In a sample of 231 healthy control subjects (19-55 years of age), we used an RPS to study the effect of several LOAD risk loci reported in a recent meta-analysis on hippocampal function (determined by its engagement with blood oxygen level-dependent functional magnetic resonance imaging during episodic memory) and several cognitive metrics. We also studied effects on brain morphometry in an overlapping sample of 280 subjects. There was almost no significant association of LOAD-RPS with cognitive or morphometric measures. However, there was a significant negative relationship between LOAD-RPS and hippocampal function (familywise error [small volume correction-hippocampal region of interest] p < .05). There were also similar associations for risk score based on APOE haplotype, and for a combined LOAD-RPS + APOE haplotype risk profile score (p < .05 familywise error [small volume correction-hippocampal region of interest]). Of the 29 individual single nucleotide polymorphisms used in calculating LOAD-RPS, variants in CLU, PICALM, BCL3, PVRL2, and RELB showed strong effects (p < .05 familywise error [small volume correction-hippocampal region of interest]) on hippocampal function, though none survived further correction for the number of single nucleotide polymorphisms tested. There is a cumulative deleterious effect of LOAD risk genes on hippocampal function even in healthy volunteers. The effect of LOAD-RPS on hippocampal function in the relative absence of any effect on cognitive and morphometric measures is consistent with the reported temporal characteristics of LOAD biomarkers with the earlier manifestation of synaptic dysfunction before morphometric and cognitive changes. Copyright © 2017 Society of Biological Psychiatry. All rights reserved.
SU-E-T-623: Polarity Effects for Small Volume Ionization Chambers in Cobalt-60 Beams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Y; Bhatnagar, J; Huq, M Saiful
2015-06-15
Purpose: To investigate the polarity effects for small volume ionization chambers in {sup 60}Co gamma-ray beams using the Leksell Gamma Knife Perfexion. Methods: Measurements were made for 7 small volume ionization chambers (a PTW 31016, an Exradin A14, 2 Capintec PR0-5P, and 3 Exradin A16) using a PTW UNIDOSwebline Universal Dosemeter and an ELEKTA solid water phantom with proper inserts. For each ion chamber, the temperature/pressure corrected electric charge readings were obtained for 16 voltage values (±50V, ±100V, ±200V, ±300V, ±400V, ±500V, ±600V, ±700V). For each voltage, a five-minute leakage charge reading and a series of 2-minute readings were continuouslymore » taken during irradiation until 5 stable signals (less than 0.05% variation) were obtained. The average of the 5 reading was then used for the calculation of the polarity corrections at the voltage and for generating the saturation curves. Results: The polarity effects are more pronounced at high or low voltages than at the medium voltages for all chambers studied. The voltage dependence of the 3 Exradin A16 chambers is similar in shape. The polarity corrections for the Exradin A16 chambers changes rapidly from about 1 at 500V to about 0.98 at 700V. The polarity corrections for the 7 ion chambers at 300V are in the range from 0.9925 (for the PTW31016) to 1.0035 (for an Exradin A16). Conclusion: The polarity corrections for certain micro-chambers are large even at normal operating voltage.« less
Use of an acoustic helium analyzer for measuring lung volumes.
Krumpe, P E; MacDannald, H J; Finley, T N; Schear, H E; Hall, J; Cribbs, D
1981-01-01
We have evaluated the use of an acoustic gas analyzer (AGA) for the measurement of total lung capacity (TLC) by single-breath helium dilution. The AGA has a rapid response time (0-90% response = 160 ms for 10% He), is linear for helium concentration of 0.1-10%, is stable over a wide range of ambient temperatures, and is small and portable. We plotted the output of the AGA vs. expired lung volume after a vital capacity breath of 10% He. However, since the AGA is sensitive to changes in speed of sound relative to air, the AGA output signal also reports an artifact due to alveolar gases. We corrected for this artifact by replotting a single-breath expiration after a vital capacity breath of room air. Mean alveolar helium concentration (HeA) was then measured by planimetry, using this alveolar gas curve as the base line. TLC was calculated using the HeA from the corrected AGA output and compared with TLC calculated from HeA simultaneously measured using a mass spectrometer (MS). In 12 normal subjects and 9 patients with chronic obstructive pulmonary disease (COPD) TLC-AGA and TLC-MS were compared by linear regression analysis; correlation coefficient (r) was 0.973 for normals and 0.968 for COPD patients (P less than 0.001). This single-breath; estimation of TLC using the corrected signal of the AGA vs. Expired volume seems ideally suited for the measurement of subdivisions of lung volume in field studies.
What approach to brain partial volume correction is best for PET/MRI?
NASA Astrophysics Data System (ADS)
Hutton, B. F.; Thomas, B. A.; Erlandsson, K.; Bousse, A.; Reilhac-Laborde, A.; Kazantsev, D.; Pedemonte, S.; Vunckx, K.; Arridge, S. R.; Ourselin, S.
2013-02-01
Many partial volume correction approaches make use of anatomical information, readily available in PET/MRI systems but it is not clear what approach is best. Seven novel approaches to partial volume correction were evaluated, including several post-reconstruction methods and several reconstruction methods that incorporate anatomical information. These were compared with an MRI-independent approach (reblurred van Cittert ) and uncorrected data. Monte Carlo PET data were generated for activity distributions representing both 18F FDG and amyloid tracer uptake. Post-reconstruction methods provided the best recovery with ideal segmentation but were particularly sensitive to mis-registration. Alternative approaches performed better in maintaining lesion contrast (unseen in MRI) with good noise control. These were also relatively insensitive to mis-registration errors. The choice of method will depend on the specific application and reliability of segmentation and registration algorithms.
Tsai, Wei-Chung; Lee, Kun-Tai; Wu, Ming-Tsang; Chu, Chih-Sheng; Lin, Tsung-Hsien; Hsu, Po-Chao; Su, Ho-Ming; Voon, Wen-Chol; Lai, Wen-Ter; Sheu, Sheng-Hsiung
2013-07-01
The 12-lead electrocardiogram (ECG) is a commonly used tool to access left atrial enlargement, which is a marker of left ventricular diastolic dysfunction (LVDD). The aim of this study was to evaluate any association of the P-wave measurements in ECG with left atrial volume (LAV) index and LVDD. This study enrolled 270 patients. In this study, 4 ECG P-wave parameters corrected by heart rate, that is, corrected P-wave maximum duration (PWdurMaxC), corrected P-wave dispersion (PWdisperC), corrected P-wave area (PWareaC) and corrected mean P-wave duration (meanPWdurC), were measured. LAV and left ventricular diastolic parameters were measured from echocardiography. LVDD was defined as a pseudonormal or restrictive mitral inflow pattern. The 4 P-wave parameters were significantly correlated with the LAV index after adjusting for age, sex, diabetes, hypertension, coronary artery disease, body mass index and diastolic blood pressure in multivariate analysis. The standardized β coefficients of PWdurMaxC, PWdisperC, meanPWdurC and PWareaC were 0.338, 0.298, 0.215 and 0.296, respectively. The 4 P-wave parameters were also significantly correlated with LVDD after multivariate logistic regression analysis. The odds ratios (95% confidence intervals) of PWdurMaxC, PWdisperC, meanPWdurC and PWareaC were 1.03 (1.01-1.04), 1.02 (1.04-1.04), 1.04 (1.02-1.07) and 1.01 (1.00-1.02), respectively. This study demonstrated that PWdurMaxC, PWdisperC, meanPWdurC and PWareaC were important determinants of the LAV index and LVDD. Therefore, screening patients by means of the 12-lead ECG may be helpful in identifying a high-risk group of increased LAV index and LVDD.
Molecular Volumes and the Stokes-Einstein Equation
ERIC Educational Resources Information Center
Edward, John T.
1970-01-01
Examines the limitations of the Stokes-Einstein equation as it applies to small solute molecules. Discusses molecular volume determinations by atomic increments, molecular models, molar volumes of solids and liquids, and molal volumes. Presents an empirical correction factor for the equation which applies to molecular radii as small as 2 angstrom…
Buccal Fat Pad: An Effective Option for Facial Reconstruction and Aesthetic Augmentation.
Kim, Jeong Tae; Sasidaran, Ramesh
2017-12-01
Autogenous grafting with lipoaspirate and dermo-fat grafting are popular techniques employed by plastic surgeons for correcting small volume facial defects and contour deformities. These techniques however present certain disadvantages. In this article, we present the use of the buccal fat pad graft as an alternative method of correcting such facial deformities. Free buccal fat pad grafting was carried out in 15 patients in our institution. All were harvested using an intraoral approach. The buccal fat pad graft was used to correct periorbital contour depressions, nasal tip deformities, as a camouflage graft over exposed silicon nasal implants and as a filler in the depression deformity after mass excision. All 15 patients demonstrated good contour deformity correction without a significant graft resorption up to 3 years of follow-up. There were no donor site complications. The amount used ranged from 1 to 5 cc in volume as a spacer or barrier for the moderate-sized volume defect or depression, even though more than 5 cc of fat graft could be harvested if required. In conclusion, the buccal fat pad graft represents an easy, expedient and exceptional tool for the correction of contour deformities, volume replacement or for aesthetic augmentation. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
DOE Office of Scientific and Technical Information (OSTI.GOV)
Michels-Clark, Tara M.; Savici, Andrei T.; Lynch, Vickie E.
Evidence is mounting that potentially exploitable properties of technologically and chemically interesting crystalline materials are often attributable to local structure effects, which can be observed as modulated diffuse scattering (mDS) next to Bragg diffraction (BD). BD forms a regular sparse grid of intense discrete points in reciprocal space. Traditionally, the intensity of each Bragg peak is extracted by integration of each individual reflection first, followed by application of the required corrections. In contrast, mDS is weak and covers expansive volumes of reciprocal space close to, or between, Bragg reflections. For a representative measurement of the diffuse scattering, multiple sample orientationsmore » are generally required, where many points in reciprocal space are measured multiple times and the resulting data are combined. The common post-integration data reduction method is not optimal with regard to counting statistics. A general and inclusive data processing method is needed. In this contribution, a comprehensive data analysis approach is introduced to correct and merge the full volume of scattering data in a single step, while correctly accounting for the statistical weight of the individual measurements. Lastly, development of this new approach required the exploration of a data treatment and correction protocol that includes the entire collected reciprocal space volume, using neutron time-of-flight or wavelength-resolved data collected at TOPAZ at the Spallation Neutron Source at Oak Ridge National Laboratory.« less
Michels-Clark, Tara M.; Savici, Andrei T.; Lynch, Vickie E.; ...
2016-03-01
Evidence is mounting that potentially exploitable properties of technologically and chemically interesting crystalline materials are often attributable to local structure effects, which can be observed as modulated diffuse scattering (mDS) next to Bragg diffraction (BD). BD forms a regular sparse grid of intense discrete points in reciprocal space. Traditionally, the intensity of each Bragg peak is extracted by integration of each individual reflection first, followed by application of the required corrections. In contrast, mDS is weak and covers expansive volumes of reciprocal space close to, or between, Bragg reflections. For a representative measurement of the diffuse scattering, multiple sample orientationsmore » are generally required, where many points in reciprocal space are measured multiple times and the resulting data are combined. The common post-integration data reduction method is not optimal with regard to counting statistics. A general and inclusive data processing method is needed. In this contribution, a comprehensive data analysis approach is introduced to correct and merge the full volume of scattering data in a single step, while correctly accounting for the statistical weight of the individual measurements. Lastly, development of this new approach required the exploration of a data treatment and correction protocol that includes the entire collected reciprocal space volume, using neutron time-of-flight or wavelength-resolved data collected at TOPAZ at the Spallation Neutron Source at Oak Ridge National Laboratory.« less
Benfatti, Ricardo Ádala; Carli, Amanda Ferreira; Silva, Guilherme Viotto Rodrigues da; Dias, Amaury Edgardo Mont'serrat Ávila Souza; Goldiano, José Anderson; Pontes, José Carlos Dorsa Vieira
2010-01-01
The epsilon aminocaproic acid is an antifibrinolytic used in cardiovascular surgery to inhibit the fibrinolysis and to reduce the bleeding after CPB. [corrected] To analyze the influence of the using of epsilon aminocaproic acid in the bleeding and in red-cell transfusion requirement in the first twenty-four hours postoperative of mitral valve surgery. Prospective studying, forty-two patients, randomized and divided in two equal groups: group #1 control and group #2--epsilon aminocaproic acid. In Group II were infused five grams of EACA in the induction of anesthesia, after full heparinization, CPB perfusate after reversal of heparin and one hour after the surgery, totaling 25 grams. In group I, saline solution was infused only in those moments. Group #1 showed average bleeding volume of 633.57 ± 305,7 ml, and Group #2, an average of 308.81 ± 210.1 ml, with significant statistic difference (P = 0.0003). Average volume of red-cell transfusion requirement in Groups 1 and 2 was, respectively, 942.86 ± 345.79 ml and 214.29 ± 330.58 ml, with significant difference (P < 0.0001). The epsilon aminocaproic acid was able to reduce the bleeding volume and the red-cell transfusion requirement in the immediate postoperative of patients submitted to mitral valve surgery.
Ghosh, Payel; Chandler, Adam G; Altinmakas, Emre; Rong, John; Ng, Chaan S
2016-01-01
The aim of this study was to investigate the feasibility of shuttle-mode computed tomography (CT) technology for body perfusion applications by quantitatively assessing and correcting motion artifacts. Noncontrast shuttle-mode CT scans (10 phases, 2 nonoverlapping bed locations) were acquired from 4 patients on a GE 750HD CT scanner. Shuttling effects were quantified using Euclidean distances (between-phase and between-bed locations) of corresponding fiducial points on the shuttle and reference phase scans (prior to shuttle mode). Motion correction with nonrigid registration was evaluated using sum-of-squares differences and distances between centers of segmented volumes of interest on shuttle and references images. Fiducial point analysis showed an average shuttling motion of 0.85 ± 1.05 mm (between-bed) and 1.18 ± 1.46 mm (between-phase), respectively. The volume-of-interest analysis of the nonrigid registration results showed improved sum-of-squares differences from 2950 to 597, between-bed distance from 1.64 to 1.20 mm, and between-phase distance from 2.64 to 1.33 mm, respectively, averaged over all cases. Shuttling effects introduced during shuttle-mode CT acquisitions can be computationally corrected for body perfusion applications.
2000-02-01
1-4 1.2 .2 .3 S oil ... oil ...................................................................................................... 5-2 5.2.3 Surface W ater...S oil ............................................................................................................. 6-2 6.2.2 G roundw ater
Lavretsky, Helen; Roybal, Donna J; Ballmaier, Martina; Toga, Arthur W; Kumar, Anand
2005-08-01
Depressed elderly patients with and without antidepressant exposure were compared to normal controls to examine the effects of prior antidepressant exposure on regional brain gray matter volumes using magnetic resonance imaging (MRI). The study was conducted from October 1999 to January 2003. Patients and controls were closely matched by age and education. They underwent comprehensive neuropsychiatric and physical examinations. Measures of the total frontal lobe and the frontal gray and white matter volumes corrected by the intracranial volume were obtained using MRI, together with clinical measures of medical burden. Historical information about prior exposure to antidepressant drugs was collected using multiple information sources. The groups were compared using multivariate analyses of covariance, controlling for age, sex, and medical burden. The study sample comprised 41 patients who met the DSM-IV criteria for major depressive disorder (32 women; 11 antidepressant exposure and 30 drug-naive; mean age 70.5 years) and 41 controls (20 women; mean age 72.2 years). In the multivariate analysis, the depressed group had smaller corrected orbitofrontal cortex (OFC) total and gray matter volumes compared to the controls (p < .01). However, depressed patients with prior antidepressant exposure had larger OFC gray matter volumes compared to drug-naive depressed patients, but smaller than those in normal controls (p = .005). This effect was not explained by the group differences in sex ratio, age at onset of depression, or the number or duration of depressive episodes. We observed larger OFC regional volumes in depressed patients exposed to antidepressants compared to the drug-naive depressed subjects, but smaller than those in age-matched controls. Antidepressant exposure may protect against gray matter loss in geriatric depression.
Effects of finite volume on the K L – K S mass difference
Christ, N. H.; Feng, X.; Martinelli, G.; ...
2015-06-24
Phenomena that involve two or more on-shell particles are particularly sensitive to the effects of finite volume and require special treatment when computed using lattice QCD. In this paper we generalize the results of Lüscher and Lellouch and Lüscher, which determine the leading-order effects of finite volume on the two-particle spectrum and two-particle decay amplitudes to determine the finite-volume effects in the second-order mixing of the K⁰ and K⁰⁻ states. We extend the methods of Kim, Sachrajda, and Sharpe to provide a direct, uniform treatment of these three, related, finite-volume corrections. In particular, the leading, finite-volume corrections to the Kmore » L – K S mass difference ΔM K and the CP-violating parameter εK are determined, including the potentially large effects which can arise from the near degeneracy of the kaon mass and the energy of a finite-volume, two-pion state.« less
Wu, Naijun; Bradley, Ashley C; Welch, Christopher J; Zhang, Li
2012-08-01
Effects of extra-column volume on apparent separation parameters were studied in ultra-high pressure liquid chromatography with columns and inlet connection tubings of various internal diameters (id) using 50-mm long columns packed with 1.8-μm particles under isocratic conditions. The results showed that apparent retention factors were on average 5, 11, 18, and 41% lower than those corrected with extra-column volumes for 4.6-, 3.0-, 2.1-, and 1.0-mm id columns, respectively, when the extra-column volume (11.3 μL) was kept constant. Also, apparent pressures were 31, 16, 12, and 10% higher than those corrected with pressures from extra-column volumes for 4.6-, 3.0-, 2.1-, and 1.0-mm id columns at the respective optimum flow rate for a typical ultra-high pressure liquid chromatography system. The loss in apparent efficiency increased dramatically from 4.6- to 3.0- to 2.1- to 1.0-mm id columns, less significantly as retention factors increased. The column efficiency was significantly improved as the inlet tubing id was decreased for a given column. The results suggest that maximum ratio of extra-column volume to column void volume should be approximately 1:10 for column porosity more than 0.6 and a retention factor more than 5, where 80% or higher of theoretically predicted efficiency could be achieved. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Real-time fMRI processing with physiological noise correction - Comparison with off-line analysis.
Misaki, Masaya; Barzigar, Nafise; Zotev, Vadim; Phillips, Raquel; Cheng, Samuel; Bodurka, Jerzy
2015-12-30
While applications of real-time functional magnetic resonance imaging (rtfMRI) are growing rapidly, there are still limitations in real-time data processing compared to off-line analysis. We developed a proof-of-concept real-time fMRI processing (rtfMRIp) system utilizing a personal computer (PC) with a dedicated graphic processing unit (GPU) to demonstrate that it is now possible to perform intensive whole-brain fMRI data processing in real-time. The rtfMRIp performs slice-timing correction, motion correction, spatial smoothing, signal scaling, and general linear model (GLM) analysis with multiple noise regressors including physiological noise modeled with cardiac (RETROICOR) and respiration volume per time (RVT). The whole-brain data analysis with more than 100,000voxels and more than 250volumes is completed in less than 300ms, much faster than the time required to acquire the fMRI volume. Real-time processing implementation cannot be identical to off-line analysis when time-course information is used, such as in slice-timing correction, signal scaling, and GLM. We verified that reduced slice-timing correction for real-time analysis had comparable output with off-line analysis. The real-time GLM analysis, however, showed over-fitting when the number of sampled volumes was small. Our system implemented real-time RETROICOR and RVT physiological noise corrections for the first time and it is capable of processing these steps on all available data at a given time, without need for recursive algorithms. Comprehensive data processing in rtfMRI is possible with a PC, while the number of samples should be considered in real-time GLM. Copyright © 2015 Elsevier B.V. All rights reserved.
Pfützner, Andreas; Schipper, Christina; Ramljak, Sanja; Flacke, Frank; Sieber, Jochen; Forst, Thomas; Musholt, Petra B
2013-11-01
Accuracy of blood glucose readings is (among other things) dependent on the test strip being completely filled with sufficient sample volume. The devices are supposed to display an error message in case of incomplete filling. This laboratory study was performed to test the performance of 31 commercially available devices in case of incomplete strip filling. Samples with two different glucose levels (60-90 and 300-350 mg/dl) were used to generate three different sample volumes: 0.20 µl (too low volume for any device), 0.32 µl (borderline volume), and 1.20 µl (low but supposedly sufficient volume for all devices). After a point-of-care capillary reference measurement (StatStrip, NovaBiomedical), the meter strip was filled (6x) with the respective volume, and the response of the meters (two devices) was documented (72 determinations/meter type). Correct response was defined as either an error message indicating incomplete filling or a correct reading (±20% compared with reference reading). Only five meters showed 100% correct responses [BGStar and iBGStar (both Sanofi), ACCU-CHEK Compact+ and ACCU-CHEK Mobile (both Roche Diagnostics), OneTouch Verio (LifeScan)]. The majority of the meters (17) had up to 10% incorrect reactions [predominantly incorrect readings with sufficient volume; Precision Xceed and Xtra, FreeStyle Lite, and Freedom Lite (all Abbott); GlucoCard+ and GlucoMen GM (both Menarini); Contour, Contour USB, and Breeze2 (all Bayer); OneTouch Ultra Easy, Ultra 2, and Ultra Smart (all LifeScan); Wellion Dialog and Premium (both MedTrust); FineTouch (Terumo); ACCU-CHEK Aviva (Roche); and GlucoTalk (Axis-Shield)]. Ten percent to 20% incorrect reactions were seen with OneTouch Vita (LifeScan), ACCU-CHEK Aviva Nano (Roche), OmniTest+ (BBraun), and AlphaChek+ (Berger Med). More than 20% incorrect reactions were obtained with Pura (Ypsomed), GlucoCard Meter and GlucoMen LX (both Menarini), Elite (Bayer), and MediTouch (Medisana). In summary, partial and incomplete blood filling of glucose meter strips is often associated with inaccurate reading. These findings underline the importance of appropriate patient education on this aspect of blood glucose self-monitoring. © 2013 Diabetes Technology Society.
Effects of posture on exercise performance - Measurement by systolic time intervals.
NASA Technical Reports Server (NTRS)
Spodick, D. H.; Quarry-Pigott, V. M.
1973-01-01
Because posture significantly influences cardiac performance, the effects of moderate supine and upright ergometer exercise were compared on the basis of proportional (+37%) rate increments over resting control. Supine exercise produced significant decreases in left ventricular ejection time (LVET), pre-ejection period (PEP), and isovolumic contraction time (IVCT). Ejection time index (ETI) and corrected ejection time (LVETc) did not change significantly. Upright exercise produced greater decreases in PEP and LVET, but despite the rate increase there was no change in LVET, which resulted in sharp increases in ETI and LVETc. The discordant directional effects on LVET and its rate-correcting indices between the two postures were consistent with hemodynamic studies demonstrating lack of stroke volume change during supine exercise and increased stroke volume over control during light to moderate upright exercise.
NASA Astrophysics Data System (ADS)
Wassenaar, R. W.; Beanlands, R. S. B.; deKemp, R. A.
2004-02-01
Limited scanner resolution and cardiac motion contribute to partial volume (PV) averaging of cardiac PET images. An extravascular (EV) density image, created from the subtraction of a blood pool scan from a transmission image, has been used to correct for PV averaging in H/sub 2//sup 15/O studies using 2-D imaging but not with 3-D imaging of other tracers such as /sup 18/FDG. A cardiac phantom emulating the left ventricle was used to characterize the method for use in 3-D PET studies. Measurement of the average myocardial activity showed PV losses of 32% below the true activity (p<0.001). Initial application of the EV density correction still yielded a myocardial activity 13% below the true value (p<0.001). This failure of the EV density image was due to the 1.66 mm thick plastic barrier separating the myocardial and ventricular chambers within the phantom. Upon removal of this artifact by morphological dilation of the blood pool, the corrected myocardial value was within 2% of the true value (p=ns). Spherical ROIs (diameter of 2 to 10 mm), evenly distributed about the myocardium, were also used to calculate the average activity. The EV density image was able to account for PV averaging throughout the range of diameters to within a 5% accuracy, however, a small bias was seen as the size of the ROIs increased. This indicated a slight mismatch between the emission and transmission image resolutions, a result of the difference in data acquisitions (i.e., span and ring difference) and default smoothing. These results show that the use of EV density image to correct for PV averaging is possible with 3-D PET. A method of correcting barrier effects in phantoms has been presented, as well as a process for evaluating resolution mismatch.
Segmentation-free empirical beam hardening correction for CT.
Schüller, Sören; Sawall, Stefan; Stannigel, Kai; Hülsbusch, Markus; Ulrici, Johannes; Hell, Erich; Kachelrieß, Marc
2015-02-01
The polychromatic nature of the x-ray beams and their effects on the reconstructed image are often disregarded during standard image reconstruction. This leads to cupping and beam hardening artifacts inside the reconstructed volume. To correct for a general cupping, methods like water precorrection exist. They correct the hardening of the spectrum during the penetration of the measured object only for the major tissue class. In contrast, more complex artifacts like streaks between dense objects need other techniques of correction. If using only the information of one single energy scan, there are two types of corrections. The first one is a physical approach. Thereby, artifacts can be reproduced and corrected within the original reconstruction by using assumptions in a polychromatic forward projector. These assumptions could be the used spectrum, the detector response, the physical attenuation and scatter properties of the intersected materials. A second method is an empirical approach, which does not rely on much prior knowledge. This so-called empirical beam hardening correction (EBHC) and the previously mentioned physical-based technique are both relying on a segmentation of the present tissues inside the patient. The difficulty thereby is that beam hardening by itself, scatter, and other effects, which diminish the image quality also disturb the correct tissue classification and thereby reduce the accuracy of the two known classes of correction techniques. The herein proposed method works similar to the empirical beam hardening correction but does not require a tissue segmentation and therefore shows improvements on image data, which are highly degraded by noise and artifacts. Furthermore, the new algorithm is designed in a way that no additional calibration or parameter fitting is needed. To overcome the segmentation of tissues, the authors propose a histogram deformation of their primary reconstructed CT image. This step is essential for the proposed algorithm to be segmentation-free (sf). This deformation leads to a nonlinear accentuation of higher CT-values. The original volume and the gray value deformed volume are monochromatically forward projected. The two projection sets are then monomially combined and reconstructed to generate sets of basis volumes which are used for correction. This is done by maximization of the image flatness due to adding additionally a weighted sum of these basis images. sfEBHC is evaluated on polychromatic simulations, phantom measurements, and patient data. The raw data sets were acquired by a dual source spiral CT scanner, a digital volume tomograph, and a dual source micro CT. Different phantom and patient data were used to illustrate the performance and wide range of usability of sfEBHC across different scanning scenarios. The artifact correction capabilities are compared to EBHC. All investigated cases show equal or improved image quality compared to the standard EBHC approach. The artifact correction is capable of correcting beam hardening artifacts for different scan parameters and scan scenarios. sfEBHC generates beam hardening-reduced images and is furthermore capable of dealing with images which are affected by high noise and strong artifacts. The algorithm can be used to recover structures which are hardly visible inside the beam hardening-affected regions.
Segmentation-free empirical beam hardening correction for CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schüller, Sören; Sawall, Stefan; Stannigel, Kai
2015-02-15
Purpose: The polychromatic nature of the x-ray beams and their effects on the reconstructed image are often disregarded during standard image reconstruction. This leads to cupping and beam hardening artifacts inside the reconstructed volume. To correct for a general cupping, methods like water precorrection exist. They correct the hardening of the spectrum during the penetration of the measured object only for the major tissue class. In contrast, more complex artifacts like streaks between dense objects need other techniques of correction. If using only the information of one single energy scan, there are two types of corrections. The first one ismore » a physical approach. Thereby, artifacts can be reproduced and corrected within the original reconstruction by using assumptions in a polychromatic forward projector. These assumptions could be the used spectrum, the detector response, the physical attenuation and scatter properties of the intersected materials. A second method is an empirical approach, which does not rely on much prior knowledge. This so-called empirical beam hardening correction (EBHC) and the previously mentioned physical-based technique are both relying on a segmentation of the present tissues inside the patient. The difficulty thereby is that beam hardening by itself, scatter, and other effects, which diminish the image quality also disturb the correct tissue classification and thereby reduce the accuracy of the two known classes of correction techniques. The herein proposed method works similar to the empirical beam hardening correction but does not require a tissue segmentation and therefore shows improvements on image data, which are highly degraded by noise and artifacts. Furthermore, the new algorithm is designed in a way that no additional calibration or parameter fitting is needed. Methods: To overcome the segmentation of tissues, the authors propose a histogram deformation of their primary reconstructed CT image. This step is essential for the proposed algorithm to be segmentation-free (sf). This deformation leads to a nonlinear accentuation of higher CT-values. The original volume and the gray value deformed volume are monochromatically forward projected. The two projection sets are then monomially combined and reconstructed to generate sets of basis volumes which are used for correction. This is done by maximization of the image flatness due to adding additionally a weighted sum of these basis images. sfEBHC is evaluated on polychromatic simulations, phantom measurements, and patient data. The raw data sets were acquired by a dual source spiral CT scanner, a digital volume tomograph, and a dual source micro CT. Different phantom and patient data were used to illustrate the performance and wide range of usability of sfEBHC across different scanning scenarios. The artifact correction capabilities are compared to EBHC. Results: All investigated cases show equal or improved image quality compared to the standard EBHC approach. The artifact correction is capable of correcting beam hardening artifacts for different scan parameters and scan scenarios. Conclusions: sfEBHC generates beam hardening-reduced images and is furthermore capable of dealing with images which are affected by high noise and strong artifacts. The algorithm can be used to recover structures which are hardly visible inside the beam hardening-affected regions.« less
Prell, Daniel; Kyriakou, Yiannis; Beister, Marcel; Kalender, Willi A
2009-11-07
Metallic implants generate streak-like artifacts in flat-detector computed tomography (FD-CT) reconstructed volumetric images. This study presents a novel method for reducing these disturbing artifacts by inserting discarded information into the original rawdata using a three-step correction procedure and working directly with each detector element. Computation times are minimized by completely implementing the correction process on graphics processing units (GPUs). First, the original volume is corrected using a three-dimensional interpolation scheme in the rawdata domain, followed by a second reconstruction. This metal artifact-reduced volume is then segmented into three materials, i.e. air, soft-tissue and bone, using a threshold-based algorithm. Subsequently, a forward projection of the obtained tissue-class model substitutes the missing or corrupted attenuation values directly for each flat detector element that contains attenuation values corresponding to metal parts, followed by a final reconstruction. Experiments using tissue-equivalent phantoms showed a significant reduction of metal artifacts (deviations of CT values after correction compared to measurements without metallic inserts reduced typically to below 20 HU, differences in image noise to below 5 HU) caused by the implants and no significant resolution losses even in areas close to the inserts. To cover a variety of different cases, cadaver measurements and clinical images in the knee, head and spine region were used to investigate the effectiveness and applicability of our method. A comparison to a three-dimensional interpolation correction showed that the new approach outperformed interpolation schemes. Correction times are minimized, and initial and corrected images are made available at almost the same time (12.7 s for the initial reconstruction, 46.2 s for the final corrected image compared to 114.1 s and 355.1 s on central processing units (CPUs)).
Ladefoged, Claes N; Hansen, Adam E; Keller, Sune H; Fischer, Barbara M; Rasmussen, Jacob H; Law, Ian; Kjær, Andreas; Højgaard, Liselotte; Lauze, Francois; Beyer, Thomas; Andersen, Flemming L
2015-12-01
In the absence of CT or traditional transmission sources in combined clinical positron emission tomography/magnetic resonance (PET/MR) systems, MR images are used for MR-based attenuation correction (MR-AC). The susceptibility effects due to metal implants challenge MR-AC in the neck region of patients with dental implants. The purpose of this study was to assess the frequency and magnitude of subsequent PET image distortions following MR-AC. A total of 148 PET/MR patients with clear visual signal voids on the attenuation map in the dental region were included in this study. Patients were injected with [(18)F]-FDG, [(11)C]-PiB, [(18)F]-FET, or [(64)Cu]-DOTATATE. The PET/MR data were acquired over a single-bed position of 25.8 cm covering the head and neck. MR-AC was based on either standard MR-ACDIXON or MR-ACINPAINTED where the susceptibility-induced signal voids were substituted with soft tissue information. Our inpainting algorithm delineates the outer contour of signal voids breaching the anatomical volume using the non-attenuation-corrected PET image and classifies the inner air regions based on an aligned template of likely dental artifact areas. The reconstructed PET images were evaluated visually and quantitatively using regions of interests in reference regions. The volume of the artifacts and the computed relative differences in mean and max standardized uptake value (SUV) between the two PET images are reported. The MR-based volume of the susceptibility-induced signal voids on the MR-AC attenuation maps was between 1.6 and 520.8 mL. The corresponding/resulting bias of the reconstructed tracer distribution was localized mainly in the area of the signal void. The mean and maximum SUVs averaged across all patients increased after inpainting by 52% (± 11%) and 28% (± 11%), respectively, in the corrected region. SUV underestimation decreased with the distance to the signal void and correlated with the volume of the susceptibility artifact on the MR-AC attenuation map. Metallic dental work may cause severe MR signal voids. The resulting PET/MR artifacts may exceed the actual volume of the dental fillings. The subsequent bias in PET is severe in regions in and near the signal voids and may affect the conspicuity of lesions in the mandibular region.
40 CFR 1065.695 - Data requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... restriction. (v) Charge air cooler volume. (vi) Charge air cooler outlet temperature, specified engine.... (iii) “Dry-to-wet” correction. (iv) NMHC, CH4, and contamination correction. (v) NOX humidity...
Levchenko, I; Xu, S; Teel, G; Mariotti, D; Walker, M L R; Keidar, M
2018-04-10
The original PDF version of this Article had an incorrect volume number of '8'; it should have been '9'. This has been corrected in the PDF version of the Article. The HTML version was correct from the time of publication.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mashouf, Shahram; Department of Radiation Oncology, Sunnybrook Odette Cancer Centre, Toronto, Ontario; Fleury, Emmanuelle
Purpose: The inhomogeneity correction factor (ICF) method provides heterogeneity correction for the fast calculation TG43 formalism in seed brachytherapy. This study compared ICF-corrected plans to their standard TG43 counterparts, looking at their capacity to assess inadequate coverage and/or risk of any skin toxicities for patients who received permanent breast seed implant (PBSI). Methods and Materials: Two-month postimplant computed tomography scans and plans of 140 PBSI patients were used to calculate dose distributions by using the TG43 and the ICF methods. Multiple dose-volume histogram (DVH) parameters of clinical target volume (CTV) and skin were extracted and compared for both ICF and TG43more » dose distributions. Short-term (desquamation and erythema) and long-term (telangiectasia) skin toxicity data were available on 125 and 110 of the patients, respectively, at the time of the study. The predictive value of each DVH parameter of skin was evaluated using the area under the receiver operating characteristic (ROC) curve for each toxicity endpoint. Results: Dose-volume histogram parameters of CTV, calculated using the ICF method, showed an overall decrease compared to TG43, whereas those of skin showed an increase, confirming previously reported findings of the impact of heterogeneity with low-energy sources. The ICF methodology enabled us to distinguish patients for whom the CTV V{sub 100} and V{sub 90} are up to 19% lower compared to TG43, which could present a risk of recurrence not detected when heterogeneity are not accounted for. The ICF method also led to an increase in the prediction of desquamation, erythema, and telangiectasia for 91% of skin DVH parameters studied. Conclusions: The ICF methodology has the advantage of distinguishing any inadequate dose coverage of CTV due to breast heterogeneity, which can be missed by TG43. Use of ICF correction also led to an increase in prediction accuracy of skin toxicities in most cases.« less
Mashouf, Shahram; Fleury, Emmanuelle; Lai, Priscilla; Merino, Tomas; Lechtman, Eli; Kiss, Alex; McCann, Claire; Pignol, Jean-Philippe
2016-03-15
The inhomogeneity correction factor (ICF) method provides heterogeneity correction for the fast calculation TG43 formalism in seed brachytherapy. This study compared ICF-corrected plans to their standard TG43 counterparts, looking at their capacity to assess inadequate coverage and/or risk of any skin toxicities for patients who received permanent breast seed implant (PBSI). Two-month postimplant computed tomography scans and plans of 140 PBSI patients were used to calculate dose distributions by using the TG43 and the ICF methods. Multiple dose-volume histogram (DVH) parameters of clinical target volume (CTV) and skin were extracted and compared for both ICF and TG43 dose distributions. Short-term (desquamation and erythema) and long-term (telangiectasia) skin toxicity data were available on 125 and 110 of the patients, respectively, at the time of the study. The predictive value of each DVH parameter of skin was evaluated using the area under the receiver operating characteristic (ROC) curve for each toxicity endpoint. Dose-volume histogram parameters of CTV, calculated using the ICF method, showed an overall decrease compared to TG43, whereas those of skin showed an increase, confirming previously reported findings of the impact of heterogeneity with low-energy sources. The ICF methodology enabled us to distinguish patients for whom the CTV V100 and V90 are up to 19% lower compared to TG43, which could present a risk of recurrence not detected when heterogeneity are not accounted for. The ICF method also led to an increase in the prediction of desquamation, erythema, and telangiectasia for 91% of skin DVH parameters studied. The ICF methodology has the advantage of distinguishing any inadequate dose coverage of CTV due to breast heterogeneity, which can be missed by TG43. Use of ICF correction also led to an increase in prediction accuracy of skin toxicities in most cases. Copyright © 2016 Elsevier Inc. All rights reserved.
Issues in quantification of registered respiratory gated PET/CT in the lung.
Cuplov, Vesna; Holman, Beverley F; McClelland, Jamie; Modat, Marc; Hutton, Brian F; Thielemans, Kris
2017-12-14
PET/CT quantification of lung tissue is limited by several difficulties: the lung density and local volume changes during respiration, the anatomical mismatch between PET and CT and the relative contributions of tissue, air and blood to the PET signal (the tissue fraction effect). Air fraction correction (AFC) has been shown to improve PET image quantification in the lungs. Methods to correct for the movement and anatomical mismatch involve respiratory gating and image registration techniques. While conventional registration methods only account for spatial mismatch, the Jacobian determinant of the deformable registration transformation field can be used to estimate local volume changes and could therefore potentially be used to correct (i.e. Jacobian Correction, JC) the PET signal for changes in concentration due to local volume changes. This work aims to investigate the relationship between variations in the lung due to respiration, specifically density, tracer concentration and local volume changes. In particular, we study the effect of AFC and JC on PET quantitation after registration of respiratory gated PET/CT patient data. Six patients suffering from lung cancer with solitary pulmonary nodules underwent [Formula: see text]F-FDG PET/cine-CT. The PET data were gated into six respiratory gates using displacement gating based on a real-time position management (RPM) signal and reconstructed with matched gated CT. The PET tracer concentration and tissue density were extracted from registered gated PET and CT images before and after corrections (AFC or JC) and compared to the values from the reference images. Before correction, we observed a linear correlation between the PET tracer concentration values and density. Across all gates and patients, the maximum relative change in PET tracer concentration before (after) AFC was found to be 16.2% (4.1%) and the maximum relative change in tissue density and PET tracer concentration before (after) JC was found to be 17.1% (5.5%) and 16.2% (6.8%) respectively. Overall our results show that both AFC or JC largely explain the observed changes in PET tracer activity over the respiratory cycle. We also speculate that a second order effect is related to change in fluid content but this needs further investigation. Consequently, either AFC or JC is recommended when combining lung PET images from different gates to reduce noise.
Issues in quantification of registered respiratory gated PET/CT in the lung
NASA Astrophysics Data System (ADS)
Cuplov, Vesna; Holman, Beverley F.; McClelland, Jamie; Modat, Marc; Hutton, Brian F.; Thielemans, Kris
2018-01-01
PET/CT quantification of lung tissue is limited by several difficulties: the lung density and local volume changes during respiration, the anatomical mismatch between PET and CT and the relative contributions of tissue, air and blood to the PET signal (the tissue fraction effect). Air fraction correction (AFC) has been shown to improve PET image quantification in the lungs. Methods to correct for the movement and anatomical mismatch involve respiratory gating and image registration techniques. While conventional registration methods only account for spatial mismatch, the Jacobian determinant of the deformable registration transformation field can be used to estimate local volume changes and could therefore potentially be used to correct (i.e. Jacobian Correction, JC) the PET signal for changes in concentration due to local volume changes. This work aims to investigate the relationship between variations in the lung due to respiration, specifically density, tracer concentration and local volume changes. In particular, we study the effect of AFC and JC on PET quantitation after registration of respiratory gated PET/CT patient data. Six patients suffering from lung cancer with solitary pulmonary nodules underwent 18 F-FDG PET/cine-CT. The PET data were gated into six respiratory gates using displacement gating based on a real-time position management (RPM) signal and reconstructed with matched gated CT. The PET tracer concentration and tissue density were extracted from registered gated PET and CT images before and after corrections (AFC or JC) and compared to the values from the reference images. Before correction, we observed a linear correlation between the PET tracer concentration values and density. Across all gates and patients, the maximum relative change in PET tracer concentration before (after) AFC was found to be 16.2% (4.1%) and the maximum relative change in tissue density and PET tracer concentration before (after) JC was found to be 17.1% (5.5%) and 16.2% (6.8%) respectively. Overall our results show that both AFC or JC largely explain the observed changes in PET tracer activity over the respiratory cycle. We also speculate that a second order effect is related to change in fluid content but this needs further investigation. Consequently, either AFC or JC is recommended when combining lung PET images from different gates to reduce noise.
Two-particle multichannel systems in a finite volume with arbitrary spin
Briceno, Raul A.
2014-04-08
The quantization condition for two-particle systems with arbitrary number of two-body open coupled channels, spin and masses in a finite cubic volume with either periodic or twisted boundary conditions is presented. The condition presented is in agreement with all previous studies of two-body systems in a finite volume. The result is relativistic, holds for all momenta below the three- and four-particle thresholds, and is exact up to exponential volume corrections that are governed by L/r, where L is the spatial extent of the volume and r is the range of the interactions between the particles. With hadronic systems the rangemore » of the interaction is set by the inverse of the pion mass, m π, and as a result the formalism presented is suitable for m πL>>1. Implications of the formalism for the studies of multichannel baryon-baryon systems are discussed.« less
NASA Astrophysics Data System (ADS)
Nguyen, Huong Giang T.; Horn, Jarod C.; Thommes, Matthias; van Zee, Roger D.; Espinal, Laura
2017-12-01
Addressing reproducibility issues in adsorption measurements is critical to accelerating the path to discovery of new industrial adsorbents and to understanding adsorption processes. A National Institute of Standards and Technology Reference Material, RM 8852 (ammonium ZSM-5 zeolite), and two gravimetric instruments with asymmetric two-beam balances were used to measure high-pressure adsorption isotherms. This work demonstrates how common approaches to buoyancy correction, a key factor in obtaining the mass change due to surface excess gas uptake from the apparent mass change, can impact the adsorption isotherm data. Three different approaches to buoyancy correction were investigated and applied to the subcritical CO2 and supercritical N2 adsorption isotherms at 293 K. It was observed that measuring a collective volume for all balance components for the buoyancy correction (helium method) introduces an inherent bias in temperature partition when there is a temperature gradient (i.e. analysis temperature is not equal to instrument air bath temperature). We demonstrate that a blank subtraction is effective in mitigating the biases associated with temperature partitioning, instrument calibration, and the determined volumes of the balance components. In general, the manual and subtraction methods allow for better treatment of the temperature gradient during buoyancy correction. From the study, best practices specific to asymmetric two-beam balances and more general recommendations for measuring isotherms far from critical temperatures using gravimetric instruments are offered.
Nguyen, Huong Giang T; Horn, Jarod C; Thommes, Matthias; van Zee, Roger D; Espinal, Laura
2017-12-01
Addressing reproducibility issues in adsorption measurements is critical to accelerating the path to discovery of new industrial adsorbents and to understanding adsorption processes. A National Institute of Standards and Technology Reference Material, RM 8852 (ammonium ZSM-5 zeolite), and two gravimetric instruments with asymmetric two-beam balances were used to measure high-pressure adsorption isotherms. This work demonstrates how common approaches to buoyancy correction, a key factor in obtaining the mass change due to surface excess gas uptake from the apparent mass change, can impact the adsorption isotherm data. Three different approaches to buoyancy correction were investigated and applied to the subcritical CO 2 and supercritical N 2 adsorption isotherms at 293 K. It was observed that measuring a collective volume for all balance components for the buoyancy correction (helium method) introduces an inherent bias in temperature partition when there is a temperature gradient (i.e. analysis temperature is not equal to instrument air bath temperature). We demonstrate that a blank subtraction is effective in mitigating the biases associated with temperature partitioning, instrument calibration, and the determined volumes of the balance components. In general, the manual and subtraction methods allow for better treatment of the temperature gradient during buoyancy correction. From the study, best practices specific to asymmetric two-beam balances and more general recommendations for measuring isotherms far from critical temperatures using gravimetric instruments are offered.
Van Raemdonck, Veerle; Monsieurs, Koenraad G; Aerenhouts, Dirk; De Martelaer, Kristine
2014-08-01
Cardiopulmonary resuscitation (CPR) training at school is recommended. Limited school resources prevent implementation. The learning efficacy of low-cost training strategies is unknown. To evaluate the efficacy of different CPR learning strategies using low-cost didactic tools. Children (n=593, 15-16 years) were randomized to four training conditions: (1) manikin+teacher instruction (control group), (2) manikin+video instruction, (3) foam dice+plastic bag+peer training+teacher instruction, and (4) foam dice+plastic bag+peer training+video instruction. After a 50 min training, a 3 min CPR test on a manikin was performed using SkillReporting Software (Laerdal, Norway), and repeated after 6 months. The data of children without previous CPR training were analysed. Analysis of variance and the χ-test assessed differences between groups. Complete data sets were available for 165 pupils. Initially, group 3 scored lower on the mean ventilation volume (P<0.05). The control group scored better than the alternative groups (P<0.05) on the mean compression rate. After 6 months, the differences disappeared. All groups scored equally on ventilation volume (P=0.12), compression depth (P=0.11), compression rate (P=0.10), correct hand position (P=0.46) and number of correct compressions (P=0.76). Ventilation volume was sufficient in 32% of the pupils, 18% had a correct compression depth and 59% had a correct compression rate. Training efficacy with low-cost equipment was not different from training with a manikin. The outcome for all training strategies was suboptimal. The basics of CPR can be taught with alternative equipment if manikins are not available.
Valente, João; Vieira, Pedro M; Couto, Carlos; Lima, Carlos S
2018-02-01
Poor brain extraction in Magnetic Resonance Imaging (MRI) has negative consequences in several types of brain post-extraction such as tissue segmentation and related statistical measures or pattern recognition algorithms. Current state of the art algorithms for brain extraction work on weighted T1 and T2, being not adequate for non-whole brain images such as the case of T2*FLASH@7T partial volumes. This paper proposes two new methods that work directly in T2*FLASH@7T partial volumes. The first is an improvement of the semi-automatic threshold-with-morphology approach adapted to incomplete volumes. The second method uses an improved version of a current implementation of the fuzzy c-means algorithm with bias correction for brain segmentation. Under high inhomogeneity conditions the performance of the first method degrades, requiring user intervention which is unacceptable. The second method performed well for all volumes, being entirely automatic. State of the art algorithms for brain extraction are mainly semi-automatic, requiring a correct initialization by the user and knowledge of the software. These methods can't deal with partial volumes and/or need information from atlas which is not available in T2*FLASH@7T. Also, combined volumes suffer from manipulations such as re-sampling which deteriorates significantly voxel intensity structures making segmentation tasks difficult. The proposed method can overcome all these difficulties, reaching good results for brain extraction using only T2*FLASH@7T volumes. The development of this work will lead to an improvement of automatic brain lesions segmentation in T2*FLASH@7T volumes, becoming more important when lesions such as cortical Multiple-Sclerosis need to be detected. Copyright © 2017 Elsevier B.V. All rights reserved.
Novel hyaluronic acid dermal filler: dermal gel extra physical properties and clinical outcomes.
Monheit, Gary D; Baumann, Leslie S; Gold, Michael H; Goldberg, David J; Goldman, Mitchel P; Narins, Rhoda S; Bachtell, Nathan; Garcia, Emily; Kablik, Jeffrey; Gershkovich, Julia; Burkholder, David
2010-11-01
Dermal gel extra (DGE) is a new, tightly cross-linked hyaluronic acid (HA)-based dermal filler containing lidocaine engineered to resist gel deformation and degradation. To develop a firmer gel product (DGE) and compare the efficacy and safety of DGE with nonanimal stabilized HA (NASHA) for correction of nasolabial folds (NLFs). DGE physical properties were characterized, and 140 subjects with moderate to deep NLFs were treated with DGE and NASHA in a randomized, multicenter, split-face design study. Efficacy, pain, and satisfaction were measured using appropriate standard instruments. Adverse events were monitored throughout the study. DGE has a higher modulus and a higher gel:fluid ratio than other HA fillers. Similar optimal correction was observed with DGE and NASHA through 36 weeks (9 months). Study subjects required less volume (p<.001) and fewer touch-ups (p=.005) and reported less injection pain (p<.001) with DGE treatment. Most adverse events were mild to moderate skin reactions. DGE is a firm HA gel that required significantly less volume and fewer touch-ups to provide equivalent efficacy to NASHA for NLF correction; both dermal gels were well tolerated. DGE will provide a comfortable and cost-effective dermal filler option for clinicians and patients. © 2010 by the American Society for Dermatologic Surgery, Inc.
Starr, Vanessa; Olivecrona, H; Noz, M E; Maguire, G Q; Zeleznik, M P; Jannsson, Karl-åke
2009-01-01
In this study we explore the possibility of accurately and cost-effectively monitoring tibial deformation induced by Taylor Spatial Frames (TSFs), using time-separated computed tomography (CT) scans and a volume fusion technique to determine tibial rotation and translation. Serial CT examinations (designated CT-A and CT-B, separated by a time interval of several months) of two patients were investigated using a previously described and validated volume fusion technique, in which user-defined landmarks drive the 3D registration of the two CT volumes. Both patients had undergone dual osteotomies to correct for tibial length and rotational deformity. For each registration, 10 or more landmarks were selected, and the quality of the fused volume was assessed both quantitatively and via 2D and 3D visualization tools. First, the proximal frame segment and tibia in CT-A and CT-B were brought into alignment (registered) by selecting landmarks on the frame and/or tibia. In the resulting "fused" volume, the proximal frame segment and tibia from CT-A and CT-B were aligned, while the distal frame segment and tibia from CT-A and CT-B were likely not aligned as a result of tibial deformation or frame adjustment having occurred between the CT scans. Using the proximal fused volume, the distal frame segment and tibia were then registered by selecting landmarks on the frame and/or tibia. The difference between the centroids of the final distal landmarks was used to evaluate the lengthening of the tibia, and the Euler angles from the registration were used to evaluate the rotation. Both the frame and bone could be effectively registered (based on visual interpretation). Movement between the proximal frame and proximal bone could be visualized in both cases. The spatial effect on the tibia could be both visually assessed and measured: 34 mm, 10 degrees in one case; 5 mm, 1 degrees in the other. This retrospective analysis of spatial correction of the tibia using Taylor Spatial Frames shows that CT offers an interesting potential means of quantitatively monitoring the patient's treatment. Compared with traditional techniques, modern CT scans in conjunction with image processing provide a high-resolution, spatially correct, and three-dimensional measurement system which can be used to quickly and easily assess the patient's treatment at low cost to the patient and hospital.
NASA Astrophysics Data System (ADS)
Haldar, Amritendu; Biswas, Ritabrata
2018-06-01
We investigate the effect of thermal fluctuations on the thermodynamics of a Lovelock-AdS black hole. Taking the first order logarithmic correction term in entropy we analyze the thermodynamic potentials like Helmholtz free energy, enthalpy and Gibbs free energy. We find that all the thermodynamic potentials are decreasing functions of correction coefficient α . We also examined this correction coefficient must be positive by analysing P{-}V diagram. Further we study the P{-}V criticality and stability and find that presence of logarithmic correction in it is necessary to have critical points and stable phases. When P{-}V criticality appears, we calculate the critical volume V_c, critical pressure P_c and critical temperature T_c using different equations and show that there is no critical point for this black hole without thermal fluctuations. We also study the geometrothermodynamics of this kind of black holes. The Ricci scalar of the Ruppeiner metric is graphically analysed.
Combining MRI With PET for Partial Volume Correction Improves Image-Derived Input Functions in Mice
NASA Astrophysics Data System (ADS)
Evans, Eleanor; Buonincontri, Guido; Izquierdo, David; Methner, Carmen; Hawkes, Rob C.; Ansorge, Richard E.; Krieg, Thomas; Carpenter, T. Adrian; Sawiak, Stephen J.
2015-06-01
Accurate kinetic modelling using dynamic PET requires knowledge of the tracer concentration in plasma, known as the arterial input function (AIF). AIFs are usually determined by invasive blood sampling, but this is prohibitive in murine studies due to low total blood volumes. As a result of the low spatial resolution of PET, image-derived input functions (IDIFs) must be extracted from left ventricular blood pool (LVBP) ROIs of the mouse heart. This is challenging because of partial volume and spillover effects between the LVBP and myocardium, contaminating IDIFs with tissue signal. We have applied the geometric transfer matrix (GTM) method of partial volume correction (PVC) to 12 mice injected with 18F - FDG affected by a Myocardial Infarction (MI), of which 6 were treated with a drug which reduced infarction size [1]. We utilised high resolution MRI to assist in segmenting mouse hearts into 5 classes: LVBP, infarcted myocardium, healthy myocardium, lungs/body and background. The signal contribution from these 5 classes was convolved with the point spread function (PSF) of the Cambridge split magnet PET scanner and a non-linear fit was performed on the 5 measured signal components. The corrected IDIF was taken as the fitted LVBP component. It was found that the GTM PVC method could recover an IDIF with less contamination from spillover than an IDIF extracted from PET data alone. More realistic values of Ki were achieved using GTM IDIFs, which were shown to be significantly different (p <; 0.05) between the treated and untreated groups.
Lattice study of finite volume effect in HVP for muon g-2
NASA Astrophysics Data System (ADS)
Izubuchi, Taku; Kuramashi, Yoshinobu; Lehner, Christoph; Shintani, Eigo
2018-03-01
We study the finite volume effect of the hadronic vacuum polarization contribution to muon g-2, aμhvp, in lattice QCD by comparison with two different volumes, L4 = (5.4)4 and (8.1)4 fm4, at physical pion. We perform the lattice computation of highly precise vector-vector current correlator with optimized AMA technique on Nf = 2 + 1 PACS gauge configurations in Wilson-clover fermion and stout smeared gluon action at one lattice cut-off, a-1 = 2.33 GeV. We compare two integrals of aμhvp, momentum integral and time-slice summation, on the lattice and numerically show that the different size of finite volume effect appears between two methods. We also discuss the effect of backward-state propagation into the result of aμhvp with the different boundary condition. Our model-independent study suggest that the lattice computation at physical pion is important for correct estimate of finite volume and other lattice systematics in aμhvp.
Association between brain structure and phenotypic characteristics in pedophilia.
Poeppl, Timm B; Nitschke, Joachim; Santtila, Pekka; Schecklmann, Martin; Langguth, Berthold; Greenlee, Mark W; Osterheider, Michael; Mokros, Andreas
2013-05-01
Studies applying structural neuroimaging to pedophiles are scarce and have shown conflicting results. Although first findings suggested reduced volume of the amygdala, pronounced gray matter decreases in frontal regions were observed in another group of pedophilic offenders. When compared to non-sexual offenders instead of community controls, pedophiles revealed deficiencies in white matter only. The present study sought to test the hypotheses of structurally compromised prefrontal and limbic networks and whether structural brain abnormalities are related to phenotypic characteristics in pedophiles. We compared gray matter volume of male pedophilic offenders and non-sexual offenders from high-security forensic hospitals using voxel-based morphometry in cross-sectional and correlational whole-brain analyses. The significance threshold was set to p < .05, corrected for multiple comparisons. Compared to controls, pedophiles exhibited a volume reduction of the right amygdala (small volume corrected). Within the pedophilic group, pedosexual interest and sexual recidivism were correlated with gray matter decrease in the left dorsolateral prefrontal cortex (r = -.64) and insular cortex (r = -.45). Lower age of victims was strongly associated with gray matter reductions in the orbitofrontal cortex (r = .98) and angular gyri bilaterally (r = .70 and r = .93). Our findings of specifically impaired neural networks being related to certain phenotypic characteristics might account for the heterogeneous results in previous neuroimaging studies of pedophilia. The neuroanatomical abnormalities in pedophilia seem to be of a dimensional rather than a categorical nature, supporting the notion of a multifaceted disorder. Copyright © 2013 Elsevier Ltd. All rights reserved.
Thermodynamic studies of different black holes with modifications of entropy
NASA Astrophysics Data System (ADS)
Haldar, Amritendu; Biswas, Ritabrata
2018-02-01
In recent years, the thermodynamic properties of black holes are topics of interests. We investigate the thermodynamic properties like surface gravity and Hawking temperature on event horizon of regular black holes viz. Hayward Class and asymptotically AdS (Anti-de Sitter) black holes. We also analyze the thermodynamic volume and naive geometric volume of asymptotically AdS black holes and show that the entropy of these black holes is simply the ratio of the naive geometric volume to thermodynamic volume. We plot the different graphs and interpret them physically. We derive the `cosmic-Censorship-Inequality' for both type of black holes. Moreover, we calculate the thermal heat capacity of aforesaid black holes and study their stabilities in different regimes. Finally, we compute the logarithmic correction to the entropy for both the black holes considering the quantum fluctuations around the thermal equilibrium and study the corresponding thermodynamics.
Finasteride for chronic central serous chorioretinopathy.
Forooghian, Farzin; Meleth, Annal D; Cukras, Catherine; Chew, Emily Y; Wong, Wai T; Meyerle, Catherine B
2011-04-01
To evaluate the safety and efficacy of finasteride, an inhibitor of dihydrotestosterone synthesis, in the treatment of chronic central serous chorioretinopathy. Five patients with chronic central serous chorioretinopathy were prospectively enrolled in this pilot study. Patients were administered finasteride (5 mg) daily for 3 months, after which study medication was withheld and patients were observed for 3 months. Main outcome measures included best-corrected visual acuity, central subfield macular thickness, and subretinal fluid volume as assessed by optical coherence tomography. Serum dihydrotestosterone, serum testosterone, and urinary cortisol were also measured. There was no change in mean best-corrected visual acuity. Mean center-subfield macular thickness and subretinal fluid volume reached a nadir at 3 months and rose to levels that were below baseline by 6 months. The changes in both optical coherence tomography parameters paralleled those in serum dihydrotestosterone level. In four patients, center-subfield macular thickness and/or subretinal fluid volume increased after discontinuation of finasteride. In the remaining patient, both optical coherence tomography parameters normalized with finasteride and remained stable when the study medication was discontinued. Finasteride may represent a novel medical treatment for chronic central serous chorioretinopathy. Larger controlled clinical trials are needed to further assess the efficacy of finasteride for the treatment of central serous chorioretinopathy.
NASA Technical Reports Server (NTRS)
1981-01-01
An approach to remote sensing that meets future mission requirements was investigated. The deterministic acquisition of data and the rapid correction of data for radiometric effects and image distortions are the most critical limitations of remote sensing. The following topics are discussed: onboard image correction systems, GCP navigation system simulation, GCP analysis, and image correction analysis measurement.
Ji, Ming-Liang; Qian, Bang-Ping; Qiu, Yong; Wang, Bin; Mao, Sai-Hu; Zhu, Ze-Zhang; Yu, Yang
2015-12-01
A computed tomographic study. To investigate the change in abdominal morphology in surgically treated patients with ankylosing spondylitis (AS) and thoracolumbar kyphosis. Severe thoracolumbar kyphosis in patients with AS exerts pressure on the abdominal cavity and subsequently causes intra-abdominal complications. Several spinal osteotomy techniques have been widely used to correct AS-related thoracolumbar kyphosis. To date, the changed abdominal morphology in patients with AS undergoing surgical correction of thoracolumbar kyphosis has not been addressed. A total of 29 patients with AS undergoing lumbar pedicle subtraction osteotomy for correction of thoracolumbar kyphosis were retrospectively reviewed. Computed tomographic scans of the spine were used to measure the longitudinal, transverse, and anterior-posterior diameters of the abdominal cavity. Furthermore, the abdominal cavity was considered as an ellipsoid structure, thereby allowing calculation of its volume. Radiographical evaluations included global kyphosis (GK), thoracic kyphosis, lumbar lordosis (LL), and angle of fusion levels (AFL). The longitudinal diameter of abdominal cavity significantly increased (P < 0.01), whereas the transverse and anterior-posterior diameters of the abdominal cavity did not change, postoperatively (P > 0.05). Significant changes in GK, LL, and AFL were observed (P < 0.01). The abdominal cavity volume (ACV) increased by an average of 652 mL. The change in ACV was significantly correlated with the changes in GK (r = 0.453, P = 0.014), LL (r = 0.42, P = 0.023), and AFL (r = 0.388, P = 0.037). The increased ACV after correction of thoracolumbar kyphosis was quantitatively confirmed by this study. Thus, the improvement in digestive function after correction of thoracolumbar kyphosis secondary to AS, which has been previously documented, may be because of an increase in ACV. Moreover, spine surgeons should be aware of the potential risk for the development of abdominal complications caused by the lengthening of longitudinal diameter of the abdominal cavity. 3.
Vincenti, Gabriella; Masci, Pier Giorgio; Rutz, Tobias; De Blois, Jonathan; Prša, Milan; Jeanrenaud, Xavier; Schwitter, Juerg; Monney, Pierre
2017-07-27
To quantify mitral regurgitation (MR) with CMR, the regurgitant volume can be calculated as the difference between the left ventricular (LV) stroke volume (SV) measured with the Simpson's method and the reference SV, i.e. the right ventricular SV (RVSV) in patients without tricuspid regurgitation. However, for patients with prominent mitral valve prolapse (MVP), the Simpson's method may underestimate the LV end-systolic volume (LVESV) as it only considers the volume located between the apex and the mitral annulus, and neglects the ventricular volume that is displaced into the left atrium but contained within the prolapsed mitral leaflets at end systole. This may lead to an underestimation of LVESV, and resulting an over-estimation of LVSV, and an over-estimation of mitral regurgitation. The aim of the present study was to assess the impact of prominent MVP on MR quantification by CMR. In patients with MVP (and no more than trace tricuspid regurgitation) MR was quantified by calculating the regurgitant volume as the difference between LVSV and RVSV. LVSV uncorr was calculated conventionally as LV end-diastolic (LVEDV) minus LVESV. A corrected LVESV corr was calculated as the LVESV plus the prolapsed volume, i.e. the volume between the mitral annulus and the prolapsing mitral leaflets. The 2 methods were compared with respect to the MR grading. MR grades were defined as absent or trace, mild (5-29% regurgitant fraction (RF)), moderate (30-49% RF), or severe (≥50% RF). In 35 patients (44.0 ± 23.0y, 14 males, 20 patients with MR) the prolapsed volume was 16.5 ± 8.7 ml. The 2 methods were concordant in only 12 (34%) patients, as the uncorrected method indicated a 1-grade higher MR severity in 23 (66%) patients. For the uncorrected/corrected method, the distribution of the MR grades as absent-trace (0 vs 11, respectively), mild (20 vs 18, respectively), moderate (11 vs 5, respectively), and severe (4 vs 1, respectively) was significantly different (p < 0.001). In the subgroup without MR, LVSV corr was not significantly different from RVSV (difference: 2.5 ± 4.7 ml, p = 0.11 vs 0) while a systematic overestimation was observed with LVSV uncorr (difference: 16.9 ± 9.1 ml, p = 0.0007 vs 0). Also, RVSV was highly correlated with aortic forward flow (n = 24, R 2 = 0.97, p < 0.001). For patients with severe bileaflet prolapse, the correction of the LVSV for the prolapse volume is suggested as it modified the assessment of MR severity by one grade in a large portion of patients.
Elkattan, Amal; Mahdy, Amal; Eltomey, Mohamed; Ismail, Radwa
2017-03-01
Knowledge of the effects of healthy aging on brain structures is necessary to identify abnormal changes due to diseases. Many studies have demonstrated age-related volume changes in the brain using MRI. 60 healthy individuals who had normal MRI aged from 20 years to 80 years were examined and classified into three groups: Group I: 21 persons; nine males and 12 females aging between 20-39 years old. Group II: 22 persons; 11 males and 11 females aging between 40-59 years old. Group III: 17 persons; eight males and nine females aging between 60-80 years old. Volumetric analysis was done to evaluate the effect of age, gender and hemispheric difference in the caudate and putamen by the slicer 4.3.3.1 software using 3D T1-weighted images. Data were analyzed by student's unpaired t test, ANOVA and regression analysis. The volumes of the measured and corrected caudate nuclei and putamen significantly decreased with aging in males. There was a statistically insignificant relation between the age and the volume of the measured caudate nuclei and putamen in females but there was a statistically significant relation between the age and the corrected caudate nuclei and putamen. There was no significant difference on the caudate and putamen volumes between males and females. There was no significant difference between the right and left caudate nuclei volumes. There was a leftward asymmetry in the putamen volumes. The results can be considered as a base to track individual changes with time (aging and CNS diseases). Clin. Anat. 30:175-182, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Upgraded Analytical Model of the Cylinder Test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Souers, P. Clark; Lauderbach, Lisa; Garza, Raul
2013-03-15
A Gurney-type equation was previously corrected for wall thinning and angle of tilt, and now we have added shock wave attenuation in the copper wall and air gap energy loss. Extensive calculations were undertaken to calibrate the two new energy loss mechanisms across all explosives. The corrected Gurney equation is recommended for cylinder use over the original 1943 form. The effect of these corrections is to add more energy to the adiabat values from a relative volume of 2 to 7, with low energy explosives having the largest correction. The data was pushed up to a relative volume of aboutmore » 15 and the JWL parameter ω was obtained directly. The total detonation energy density was locked to the v=7 adiabat energy density, so that the Cylinder test gives all necessary values needed to make a JWL.« less
Upgraded Analytical Model of the Cylinder Test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Souers, P. Clark; Lauderbach, Lisa; Garza, Raul
2013-03-15
A Gurney-type equation was previously corrected for wall thinning and angle of tilt, and now we have added shock wave attenuation in the copper wall and air gap energy loss. Extensive calculations were undertaken to calibrate the two new energy loss mechanisms across all explosives. The corrected Gurney equation is recommended for cylinder use over the original 1943 form. The effect of these corrections is to add more energy to the adiabat values from a relative volume of 2 to 7, with low energy explosives having the largest correction. The data was pushed up to a relative volume of aboutmore » 15 and the JWL parameter ω was obtained directly. Finally, the total detonation energy density was locked to the v = 7 adiabat energy density, so that the Cylinder test gives all necessary values needed to make a JWL.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Tao; Wang, Anzhong; Wu, Qiang
We first derive the primordial power spectra, spectral indices and runnings of both scalar and tensor perturbations of a flat inflationary universe to the second-order approximations of the slow-roll parameters, in the framework of loop quantum cosmology with the inverse-volume quantum corrections. This represents an extension of our previous work in which the parameter σ was assumed to be an integer, where σ characterizes the quantum corrections and in general can take any of values from the range σ element of (0, 6]. Restricting to the first-order approximations of the slow-roll parameters, we find corrections to the results obtained previously inmore » the literature, and point out the causes for such errors. To our best knowledge, these represent the most accurate calculations of scalar and tensor perturbations given so far in the literature. Then, fitting the perturbations to the recently released data by Planck (2015), we obtain the most severe constraints for various values of σ. Using these constraints as our referring point, we discuss whether these quantum gravitational corrections can lead to measurable signatures in the future cosmological observations. We show that, depending on the value of σ, the scale-dependent contributions to the relativistic inflationary spectra due to the inverse-volume corrections could be well within the range of the detectability of the forthcoming generations of experiments, such as the Stage IV experiments.« less
Meta-analysis reveals a lack of sexual dimorphism in human amygdala volume.
Marwha, Dhruv; Halari, Meha; Eliot, Lise
2017-02-15
The amygdala plays a key role in many affective behaviors and psychiatric disorders that differ between men and women. To test whether human amygdala volume (AV) differs reliably between the sexes, we performed a systematic review and meta-analysis of AVs reported in MRI studies of age-matched healthy male and female groups. Using four search strategies, we identified 46 total studies (58 matched samples) from which we extracted effect sizes for the sex difference in AV. All data were converted to Hedges g values and pooled effect sizes were calculated using a random-effects model. Each dataset was further meta-regressed against study year and average participant age. We found that uncorrected amygdala volume is about 10% larger in males, with pooled sex difference effect sizes of g=0.581 for right amygdala (κ=28, n=2022), 0.666 for left amygdala (κ=28, n=2006), and 0.876 for bilateral amygdala (κ=16, n=1585) volumes (all p values < 0.001). However, this difference is comparable to the sex differences in intracranial volume (ICV; g=1.186, p<.001, 11.9% larger in males, κ=11) and total brain volume (TBV; g=1.278, p<0.001, 11.5% larger in males, κ=15) reported in subsets of the same studies, suggesting the sex difference in AV is a product of larger brain size in males. Among studies reporting AVs normalized for ICV or TBV, sex difference effect sizes were small and not statistically significant: g=0.171 for the right amygdala (p=0.206, κ=13, n=1560); 0.233 for the left amygdala (p=0.092, κ=12, n=1512); and 0.257 for bilateral volume (p=0.131, κ=5, n=1629). These values correspond to less than 0.1% larger corrected right AV and 2.5% larger corrected left AV in males compared to females. In summary, AV is not selectively enhanced in human males, as often claimed. Although we cannot rule out subtle male-female group differences, it is not accurate to refer to the human amygdala as "sexually dimorphic." Copyright © 2016 Elsevier Inc. All rights reserved.
Teuho, Jarmo; Saunavaara, Virva; Tolvanen, Tuula; Tuokkola, Terhi; Karlsson, Antti; Tuisku, Jouni; Teräs, Mika
2017-10-01
In PET, corrections for photon scatter and attenuation are essential for visual and quantitative consistency. MR attenuation correction (MRAC) is generally conducted by image segmentation and assignment of discrete attenuation coefficients, which offer limited accuracy compared with CT attenuation correction. Potential inaccuracies in MRAC may affect scatter correction, because the attenuation image (μ-map) is used in single scatter simulation (SSS) to calculate the scatter estimate. We assessed the impact of MRAC to scatter correction using 2 scatter-correction techniques and 3 μ-maps for MRAC. Methods: The tail-fitted SSS (TF-SSS) and a Monte Carlo-based single scatter simulation (MC-SSS) algorithm implementations on the Philips Ingenuity TF PET/MR were used with 1 CT-based and 2 MR-based μ-maps. Data from 7 subjects were used in the clinical evaluation, and a phantom study using an anatomic brain phantom was conducted. Scatter-correction sinograms were evaluated for each scatter correction method and μ-map. Absolute image quantification was investigated with the phantom data. Quantitative assessment of PET images was performed by volume-of-interest and ratio image analysis. Results: MRAC did not result in large differences in scatter algorithm performance, especially with TF-SSS. Scatter sinograms and scatter fractions did not reveal large differences regardless of the μ-map used. TF-SSS showed slightly higher absolute quantification. The differences in volume-of-interest analysis between TF-SSS and MC-SSS were 3% at maximum in the phantom and 4% in the patient study. Both algorithms showed excellent correlation with each other with no visual differences between PET images. MC-SSS showed a slight dependency on the μ-map used, with a difference of 2% on average and 4% at maximum when a μ-map without bone was used. Conclusion: The effect of different MR-based μ-maps on the performance of scatter correction was minimal in non-time-of-flight 18 F-FDG PET/MR brain imaging. The SSS algorithm was not affected significantly by MRAC. The performance of the MC-SSS algorithm is comparable but not superior to TF-SSS, warranting further investigations of algorithm optimization and performance with different radiotracers and time-of-flight imaging. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
Ponomarev, Artem L; Costes, Sylvain V; Cucinotta, Francis A
2008-11-01
We computed probabilities to have multiple double-strand breaks (DSB), which are produced in DNA on a regional scale, and not in close vicinity, in volumes matching the size of DNA damage foci, of a large chromatin loop, and in the physical volume of DNA containing the HPRT (human hypoxanthine phosphoribosyltransferase) locus. The model is based on a Monte Carlo description of DSB formation by heavy ions in the spatial context of the entire human genome contained within the cell nucleus, as well as at the gene sequence level. We showed that a finite physical volume corresponding to a visible DNA repair focus, believed to be associated with one DSB, can contain multiple DSB due to heavy ion track structure and the DNA supercoiled topography. A corrective distribution was introduced, which was a conditional probability to have excess DSB in a focus volume, given that there was already one present. The corrective distribution was calculated for 19.5 MeV/amu N ions, 3.77 MeV/amu alpha-particles, 1000 MeV/amu Fe ions, and X-rays. The corrected initial DSB yield from the experimental data on DNA repair foci was calculated. The DSB yield based on the corrective function converts the focus yield into the DSB yield, which is comparable with the DSB yield based on the earlier PFGE experiments. The distribution of DSB within the physical limits of the HPRT gene was analyzed by a similar method as well. This corrective procedure shows the applicability of the model and empowers the researcher with a tool to better analyze focus statistics. The model enables researchers to analyze the DSB yield based on focus statistics in real experimental situations that lack one-to-one focus-to-DSB correspondance.
Heterogeneity of anatomic regions by MR volumetry in juvenile myoclonic epilepsy.
Swartz, B E; Spitz, J; Vu, A L; Mandelkern, M; Su, M L
2016-10-01
To investigate brain volumes in patients with well-characterized juvenile myoclonic epilepsy (JME). We studied the MRI images of seventeen subjects with EEG and clinically defined JME and seventeen age- and sex-matched controls using voxel-based morphometry (VBM) and automated and manual volumetry. We found no significant group differences in the cortical volumes by automated techniques for all regions or for the whole brain. However, we found a larger pulvinar nucleus in JME using VBM with small volume correction and a larger thalamus with manual volumetry (P = 0.001; corrected two-tailed t-test). By analysing the individual subjects, we determined that considerable heterogeneity exists even in this highly selected group. Histograms of all JME and matched control regions' volumes showed more subjects with JME had smaller hippocampi and larger thalami (P < 0.05; chi-square). Subjects in whom the first seizure was absence were more likely to have smaller hippocampi than their matched control, while those without absences showed no differences (P < 0.05, chi-square). There is ample evidence for frontal cortical thalamic network changes in JME, but subcortical structural differences were more distinct in this group. Given the heterogeneity of brain volumes in the clinical population, further advancement in the field will require the examination of stringent genetically controlled populations. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Improving the accuracy of CT dimensional metrology by a novel beam hardening correction method
NASA Astrophysics Data System (ADS)
Zhang, Xiang; Li, Lei; Zhang, Feng; Xi, Xiaoqi; Deng, Lin; Yan, Bin
2015-01-01
Its powerful nondestructive characteristics are attracting more and more research into the study of computed tomography (CT) for dimensional metrology, which offers a practical alternative to the common measurement methods. However, the inaccuracy and uncertainty severely limit the further utilization of CT for dimensional metrology due to many factors, among which the beam hardening (BH) effect plays a vital role. This paper mainly focuses on eliminating the influence of the BH effect in the accuracy of CT dimensional metrology. To correct the BH effect, a novel exponential correction model is proposed. The parameters of the model are determined by minimizing the gray entropy of the reconstructed volume. In order to maintain the consistency and contrast of the corrected volume, a punishment term is added to the cost function, enabling more accurate measurement results to be obtained by the simple global threshold method. The proposed method is efficient, and especially suited to the case where there is a large difference in gray value between material and background. Different spheres with known diameters are used to verify the accuracy of dimensional measurement. Both simulation and real experimental results demonstrate the improvement in measurement precision. Moreover, a more complex workpiece is also tested to show that the proposed method is of general feasibility.
77 FR 22788 - Advisory Committee on Breast Cancer in Young Women (ACBCYW); Correction
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-17
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Advisory Committee on Breast Cancer in Young Women (ACBCYW); Correction Correction: This notice was published in the Federal Register on March 20, 2012, Volume 77, Number 54, Page 16232. The meeting time and date listed...
Recent experience with design and manufacture of cine lenses
NASA Astrophysics Data System (ADS)
Thorpe, Michael D.; Dalzell, Kristen E.
2015-09-01
Modern cine lenses require a high degree of aberration correction over a large and ever expanding image size. At low to medium volume production levels, these highly corrected designs also require a workable tolerance set and compensation scheme for successful manufacture. In this paper we discuss the design and manufacture of cine lenses with reference to current designs both internal and in the patent literature and some experience in design, tolerancing and manufacturing these lenses in medium volume production.
CREPT-MCNP code for efficiency calibration of HPGe detectors with the representative point method.
Saegusa, Jun
2008-01-01
The representative point method for the efficiency calibration of volume samples has been previously proposed. For smoothly implementing the method, a calculation code named CREPT-MCNP has been developed. The code estimates the position of a representative point which is intrinsic to each shape of volume sample. The self-absorption correction factors are also given to make correction on the efficiencies measured at the representative point with a standard point source. Features of the CREPT-MCNP code are presented.
SU-E-T-223: Computed Radiography Dose Measurements of External Radiotherapy Beams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aberle, C; Kapsch, R
2015-06-15
Purpose: To obtain quantitative, two-dimensional dose measurements of external radiotherapy beams with a computed radiography (CR) system and to derive volume correction factors for ionization chambers in small fields. Methods: A commercial Kodak ACR2000i CR system with Kodak Flexible Phosphor Screen HR storage foils was used. Suitable measurement conditions and procedures were established. Several corrections were derived, including image fading, length-scale corrections and long-term stability corrections. Dose calibration curves were obtained for cobalt, 4 MV, 8 MV and 25 MV photons, and for 10 MeV, 15 MeV and 18 MeV electrons in a water phantom. Inherent measurement inhomogeneities were studiedmore » as well as directional dependence of the response. Finally, 2D scans with ionization chambers were directly compared to CR measurements, and volume correction factors were derived. Results: Dose calibration curves (0.01 Gy to 7 Gy) were obtained for multiple photon and electron beam qualities. For each beam quality, the calibration curves can be described by a single fit equation over the whole dose range. The energy dependence of the dose response was determined. The length scale on the images was adjusted scan-by-scan, typically by 2 percent horizontally and by 3 percent vertically. The remaining inhomogeneities after the system’s standard calibration procedure were corrected for. After correction, the homogeneity is on the order of a few percent. The storage foils can be rotated by up to 30 degrees without a significant effect on the measured signal. First results on the determination of volume correction factors were obtained. Conclusion: With CR, quantitative, two-dimensional dose measurements with a high spatial resolution (sub-mm) can be obtained over a large dose range. In order to make use of these advantages, several calibrations, corrections and supporting measurements are needed. This work was funded by the European Metrology Research Programme (EMRP) project HLT09 MetrExtRT Metrology for Radiotherapy using Complex Radiation Fields.« less
Finite volume effects on the electric polarizability of neutral hadrons in lattice QCD
NASA Astrophysics Data System (ADS)
Lujan, M.; Alexandru, A.; Freeman, W.; Lee, F. X.
2016-10-01
We study the finite volume effects on the electric polarizability for the neutron, neutral pion, and neutral kaon using eight dynamically generated two-flavor nHYP-clover ensembles at two different pion masses: 306(1) and 227(2) MeV. An infinite volume extrapolation is performed for each hadron at both pion masses. For the neutral kaon, finite volume effects are relatively mild. The dependence on the quark mass is also mild, and a reliable chiral extrapolation can be performed along with the infinite volume extrapolation. Our result is αK0 phys=0.356 (74 )(46 )×10-4 fm3 . In contrast, for neutron, the electric polarizability depends strongly on the volume. After removing the finite volume corrections, our neutron polarizability results are in good agreement with chiral perturbation theory. For the connected part of the neutral pion polarizability, the negative trend persists, and it is not due to finite volume effects but likely sea quark charging effects.
Ryan, Joanne; Artero, Sylvaine; Carrière, Isabelle; Maller, Jerome J; Meslin, Chantal; Ritchie, Karen; Ancelin, Marie-Laure
2016-01-01
A number of genome-wide association studies (GWAS) have investigated risk factors for major depressive disorder (MDD), however there has been little attempt to replicate these findings in population-based studies of depressive symptoms. Variants within three genes, BICC1, PCLO and GRM7 were selected for replication in our study based on the following criteria: they were identified in a prior MDD GWAS study; a subsequent study found evidence that they influenced depression risk; and there is a solid biological basis for a role in depression. We firstly investigated whether these variants were associated with depressive symptoms in our population-based cohort of 929 elderly (238 with clinical depressive symptoms and 691 controls), and secondly to investigate associations with structural brain alterations. A number of nominally significant associations were identified, but none reached Bonferroni-corrected significance levels. Common SNPs in BICC1 and PCLO were associated with a 50% and 30% decreased risk of depression, respectively. PCLO rs2522833 was also associated with the volume of grey matter (p=1.6×10(-3)), and to a lesser extent with hippocampal volume and white matter lesions. Among depressed individuals rs9870680 (GRM7) was associated with the volume of grey and white matter (p=10(-4) and 8.3×10(-3), respectively). Our results provide some support for the involvement of BICC1 and PCLO in late-life depressive disorders and preliminary evidence that these genetic variants may also influence brain structural volumes. However effect sizes remain modest and associations did not reach corrected significance levels. Further large imaging studies are needed to confirm our findings. Copyright © 2015 Elsevier B.V. and ECNP. All rights reserved.
Ding, Huanjun; Johnson, Travis; Lin, Muqing; Le, Huy Q.; Ducote, Justin L.; Su, Min-Ying; Molloi, Sabee
2013-01-01
Purpose: Quantification of breast density based on three-dimensional breast MRI may provide useful information for the early detection of breast cancer. However, the field inhomogeneity can severely challenge the computerized image segmentation process. In this work, the effect of the bias field in breast density quantification has been investigated with a postmortem study. Methods: T1-weighted images of 20 pairs of postmortem breasts were acquired on a 1.5 T breast MRI scanner. Two computer-assisted algorithms were used to quantify the volumetric breast density. First, standard fuzzy c-means (FCM) clustering was used on raw images with the bias field present. Then, the coherent local intensity clustering (CLIC) method estimated and corrected the bias field during the iterative tissue segmentation process. Finally, FCM clustering was performed on the bias-field-corrected images produced by CLIC method. The left–right correlation for breasts in the same pair was studied for both segmentation algorithms to evaluate the precision of the tissue classification. Finally, the breast densities measured with the three methods were compared to the gold standard tissue compositions obtained from chemical analysis. The linear correlation coefficient, Pearson's r, was used to evaluate the two image segmentation algorithms and the effect of bias field. Results: The CLIC method successfully corrected the intensity inhomogeneity induced by the bias field. In left–right comparisons, the CLIC method significantly improved the slope and the correlation coefficient of the linear fitting for the glandular volume estimation. The left–right breast density correlation was also increased from 0.93 to 0.98. When compared with the percent fibroglandular volume (%FGV) from chemical analysis, results after bias field correction from both the CLIC the FCM algorithms showed improved linear correlation. As a result, the Pearson's r increased from 0.86 to 0.92 with the bias field correction. Conclusions: The investigated CLIC method significantly increased the precision and accuracy of breast density quantification using breast MRI images by effectively correcting the bias field. It is expected that a fully automated computerized algorithm for breast density quantification may have great potential in clinical MRI applications. PMID:24320536
Ding, Huanjun; Johnson, Travis; Lin, Muqing; Le, Huy Q; Ducote, Justin L; Su, Min-Ying; Molloi, Sabee
2013-12-01
Quantification of breast density based on three-dimensional breast MRI may provide useful information for the early detection of breast cancer. However, the field inhomogeneity can severely challenge the computerized image segmentation process. In this work, the effect of the bias field in breast density quantification has been investigated with a postmortem study. T1-weighted images of 20 pairs of postmortem breasts were acquired on a 1.5 T breast MRI scanner. Two computer-assisted algorithms were used to quantify the volumetric breast density. First, standard fuzzy c-means (FCM) clustering was used on raw images with the bias field present. Then, the coherent local intensity clustering (CLIC) method estimated and corrected the bias field during the iterative tissue segmentation process. Finally, FCM clustering was performed on the bias-field-corrected images produced by CLIC method. The left-right correlation for breasts in the same pair was studied for both segmentation algorithms to evaluate the precision of the tissue classification. Finally, the breast densities measured with the three methods were compared to the gold standard tissue compositions obtained from chemical analysis. The linear correlation coefficient, Pearson's r, was used to evaluate the two image segmentation algorithms and the effect of bias field. The CLIC method successfully corrected the intensity inhomogeneity induced by the bias field. In left-right comparisons, the CLIC method significantly improved the slope and the correlation coefficient of the linear fitting for the glandular volume estimation. The left-right breast density correlation was also increased from 0.93 to 0.98. When compared with the percent fibroglandular volume (%FGV) from chemical analysis, results after bias field correction from both the CLIC the FCM algorithms showed improved linear correlation. As a result, the Pearson's r increased from 0.86 to 0.92 with the bias field correction. The investigated CLIC method significantly increased the precision and accuracy of breast density quantification using breast MRI images by effectively correcting the bias field. It is expected that a fully automated computerized algorithm for breast density quantification may have great potential in clinical MRI applications.
La Macchia, Mariangela; Fellin, Francesco; Amichetti, Maurizio; Cianchetti, Marco; Gianolini, Stefano; Paola, Vitali; Lomax, Antony J; Widesott, Lamberto
2012-09-18
To validate, in the context of adaptive radiotherapy, three commercial software solutions for atlas-based segmentation. Fifteen patients, five for each group, with cancer of the Head&Neck, pleura, and prostate were enrolled in the study. In addition to the treatment planning CT (pCT) images, one replanning CT (rCT) image set was acquired for each patient during the RT course. Three experienced physicians outlined on the pCT and rCT all the volumes of interest (VOIs). We used three software solutions (VelocityAI 2.6.2 (V), MIM 5.1.1 (M) by MIMVista and ABAS 2.0 (A) by CMS-Elekta) to generate the automatic contouring on the repeated CT. All the VOIs obtained with automatic contouring (AC) were successively corrected manually. We recorded the time needed for: 1) ex novo ROIs definition on rCT; 2) generation of AC by the three software solutions; 3) manual correction of AC.To compare the quality of the volumes obtained automatically by the software and manually corrected with those drawn from scratch on rCT, we used the following indexes: overlap coefficient (DICE), sensitivity, inclusiveness index, difference in volume, and displacement differences on three axes (x, y, z) from the isocenter. The time saved by the three software solutions for all the sites, compared to the manual contouring from scratch, is statistically significant and similar for all the three software solutions. The time saved for each site are as follows: about an hour for Head&Neck, about 40 minutes for prostate, and about 20 minutes for mesothelioma. The best DICE similarity coefficient index was obtained with the manual correction for: A (contours for prostate), A and M (contours for H&N), and M (contours for mesothelioma). From a clinical point of view, the automated contouring workflow was shown to be significantly shorter than the manual contouring process, even though manual correction of the VOIs is always needed.
Anatomical substrates of cognitive and clinical dimensions in first episode schizophrenia.
Rigucci, S; Rossi-Espagnet, C; Ferracuti, S; De Carolis, A; Corigliano, V; Carducci, F; Mancinelli, I; Cicone, F; Tatarelli, R; Bozzao, A; Girardi, P; Comparelli, A
2013-10-01
To explore gray (GM) and white matter (WM) abnormalities and the relationships with neuropsychopathology in first-episode schizophrenia (FES). Nineteen patients with first episode of non-affective psychosis and 18 controls underwent a magnetic resonance voxel-based morphometry. Additionally, WM fractional anisotropy (FA) was calculated. For correlative analysis, symptoms and neuropsychological performances were scored by PANSS and by a comprehensive neuropsychological assessment respectively. Patients showed significantly decreased volume of left temporal lobe and disarray of all major WM tracts. Disorganized PANSS factor was inversely related to left cerebellar GM volume (corrected P = 0.03) and to WM FA of the left cerebellum, inferior fronto-occipital fasciculi (IFOF), and inferior longitudinal fasciculi (corrected P < 0.05). PANSS negative factor was inversely related to FA in the IFOF and superior longitudinal fasciculi (corrected P < 0.05). Impairment in facial emotion identification showed associations with temporo-occipital GM volume decrease (corrected P = 0.003) and WM disarray of superior and middle temporal gyri, anterior thalamic radiation, and superior longitudinal fasciculi (corrected P < 0.05). Speed of processing and visual memory correlated with WM abnormalities in fronto-temporal tracts. These results confirm how the structural development of key brain regions is related to neuropsychopathological dysfunction in FES, consistently with a neurodevelopmentally derived misconnection syndrome. © 2012 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Treating a 20 mm Hg gradient alleviates myocardial hypertrophy in experimental aortic coarctation.
Wendell, David C; Friehs, Ingeborg; Samyn, Margaret M; Harmann, Leanne M; LaDisa, John F
2017-10-01
Children with coarctation of the aorta (CoA) can have a hyperdynamic and remodeled left ventricle (LV) from increased afterload. Literature from an experimental model suggests the putative 20 mm Hg blood pressure gradient (BPG) treatment guideline frequently implemented in CoA studies may permit irreversible vascular changes. LV remodeling from pressure overload has been studied, but data are limited following correction and using a clinically representative BPG. Rabbits underwent CoA at 10 weeks to induce a 20 mm Hg BPG using permanent or dissolvable suture thereby replicating untreated and corrected CoA, respectively. Cardiac function was evaluated at 32 weeks by magnetic resonance imaging using a spoiled cine GRE sequence (TR/TE/FA 8/2.9/20), 14 × 14-cm FOV, and 3-mm slice thickness. Images (20 frames/cycle) were acquired in 6-8 short axis views from the apex to the mitral valve annulus. LV volume, ejection fraction (EF), and mass were quantified. LV mass was elevated for CoA (5.2 ± 0.55 g) versus control (3.6 ± 0.16 g) and corrected (4.0 ± 0.44 g) rabbits, resulting in increased LV mass/volume ratio for CoA rabbits. A trend toward increased EF and stroke volume was observed but did not reach significance. Elevated EF by volumetric analysis in CoA rabbits was supported by concomitant increases in total aortic flow by phase-contrast magnetic resonance imaging. The indices quantified trended toward a persistent hyperdynamic LV despite correction, but differences were not statistically significant versus control rabbits. These findings suggest the current putative 20 mm Hg BPG for treatment may be reasonable from the LV's perspective. Copyright © 2017 Elsevier Inc. All rights reserved.
Bhaskaran, Abhishek; Barry, M A; Pouliopoulos, Jim; Nalliah, Chrishan; Qian, Pierre; Chik, William; Thavapalachandran, Sujitha; Davis, Lloyd; McEwan, Alistair; Thomas, Stuart; Kovoor, Pramesh; Thiagalingam, Aravinda
2016-03-01
Circuit impedance could affect the safety and efficacy of radiofrequency (RF) ablation. To perform irrigated RF ablations with graded impedance to compare (1) lesion dimensions and overheated dimensions in fixed power ablations (2) and in power corrected ablations. Ablations were performed with irrigated Navistar Thermocool catheter and Stockert EP shuttle generator at settings of 40 W power for 60 seconds, in a previously validated myocardial phantom. The impedance of the circuit was set at 60 Ω, 80 Ω, 100 Ω, 120 Ω, 140 Ω, and 160 Ω. The lesion and overheated dimensions were measured at 53 °C and 80 °C isotherms, respectively. In the second set of ablations, power was corrected according to circuit impedance. In total, 70 ablations were performed. The lesion volume was 72.0 ± 4.8% and 44.7 ± 4.6% higher at 80 Ω and 100 Ω, respectively, compared to that at 120 Ω and it was 15.4 ± 1.2%, 28.1 ± 2.0%, and 38.0 ± 1.8% lower at 140 Ω, 160 Ω, and 180 Ω, respectively. The overheated volume was four times larger when impedance was reduced to 80 Ω from 100 Ω. It was absent at 120 Ω and above. In the power corrected ablations, the lesion volumes were similar to that of 40 W/120 Ω ablations and there was no evidence of overheating. The lesion and overheated dimensions were significantly larger with lower circuit impedance during irrigated RF ablation and the lesion size was smaller in high impedance ablations. Power delivery adjusted to impedance using a simple equation improved the consistency of lesion formation and prevented overheating. © 2015 Wiley Periodicals, Inc.
Kurzhunov, Dmitry; Borowiak, Robert; Reisert, Marco; Özen, Ali Caglar; Bock, Michael
2018-05-16
To provide a data post-processing method that corrects for partial volume effects (PVE) and fast T2* decay in dynamic 17 O MRI for the mapping of cerebral metabolic rates of oxygen consumption (CMRO 2 ). CMRO 2 is altered in neurodegenerative diseases and tumors and can be measured after 17 O gas inhalation using dynamic 17 O MRI. CMRO 2 quantification is difficult because of PVE. To correct for PVE, a direct estimation of the MR images (DIESIS) method is proposed and used in 4 dynamic 17 O MRI data sets of a healthy volunteer acquired on a 3T MRI system. With DIESIS, 17 O MR signal time curves in selected regions were directly estimated based on parcellation of a coregistered 1 H MPRAGE image. Profile likelihood analysis of the DIESIS method showed identifiability of CMRO 2 . In white matter (WM), DIESES reduced CMRO 2 from 0.97 ± 0.25 µmol/g tissue /min with Kaiser-Bessel gridding reconstruction to 0.85 ± 0.21 µmol/g tissue /min, whereas in gray matter (GM) it increases from 1.3 ± 0.31 µmol/g tissue /min to 1.86 ± 0.36 µmol/g tissue /min; both values are closer to the literature values from the 15 O-PET studies. DIESIS provided an increased separation of CMRO 2 values in GM and WM brain regions and corrected for partial volume effects in 17 O-MRI inhalation experiments. DIESIS could also be applied to more heterogeneous tissues such as glioblastomas if subregions of the tumor can be represented as additional parcels. © 2018 International Society for Magnetic Resonance in Medicine.
Vibrational and thermodynamic properties of β-HMX: a first-principles investigation.
Wu, Zhongqing; Kalia, Rajiv K; Nakano, Aiichiro; Vashishta, Priya
2011-05-28
Thermodynamic properties of β-HMX crystal are investigated using the quasi-harmonic approximation and density functional theory within the local density approximation (LDA), generalized gradient approximation (GGA), and GGA + empirical van der Waals (vdW) correction. It is found that GGA well describes the thermal expansion coefficient and heat capacity but fails to produce correct bulk modulus and equilibrium volume. The vdW correction improves the bulk modulus and volume, but worsens the thermal expansion coefficient and heat capacity. In contrast, LDA describes all thermodynamic properties with reasonable accuracy, and overall is a good exchange-correlation functional for β-HMX molecular crystal. The results also demonstrate significant contributions of phonons to the equation of state. The static calculation of equilibrium volume for β-HMX differs from the room-temperature value incorporating lattice vibrations by over 5%. Therefore, for molecular crystals, it is essential to include phonon contributions when calculated equation of state is compared with experimental data at ambient condition. © 2011 American Institute of Physics
Refractive errors and corrections for OCT images in an inflated lung phantom
Golabchi, Ali; Faust, J.; Golabchi, F. N.; Brooks, D. H.; Gouldstone, A.; DiMarzio, C. A.
2012-01-01
Visualization and correct assessment of alveolar volume via intact lung imaging is important to study and assess respiratory mechanics. Optical Coherence Tomography (OCT), a real-time imaging technique based on near-infrared interferometry, can image several layers of distal alveoli in intact, ex vivo lung tissue. However optical effects associated with heterogeneity of lung tissue, including the refraction caused by air-tissue interfaces along alveoli and duct walls, and changes in speed of light as it travels through the tissue, result in inaccurate measurement of alveolar volume. Experimentally such errors have been difficult to analyze because of lack of ’ground truth,’ as the lung has a unique microstructure of liquid-coated thin walls surrounding relatively large airspaces, which is difficult to model with cellular foams. In addition, both lung and foams contain airspaces of highly irregular shape, further complicating quantitative measurement of optical artifacts and correction. To address this we have adapted the Bragg-Nye bubble raft, a crystalline two-dimensional arrangement of elements similar in geometry to alveoli (up to several hundred μm in diameter with thin walls) as an inflated lung phantom in order to understand, analyze and correct these errors. By applying exact optical ray tracing on OCT images of the bubble raft, the errors are predicted and corrected. The results are validated by imaging the bubble raft with OCT from one edge and with a charged coupled device (CCD) camera in transillumination from top, providing ground truth for the OCT. PMID:22567599
A new Doppler-echo method to quantify regurgitant volume.
Wang, S S; Rubenstein, J J; Goldman, M; Sidd, J J
1992-01-01
An in vitro technique using color flow imaging and continuous wave Doppler was developed to measure the initial regurgitant flow jet diameter and velocity integral to yield the parameters for a volume calculation. Jets were produced by volume-controlled injection through tubes of various diameters (1.3, 1.9, 2.8, and 3.5 mm) to deliver volumes from 1 to 7 ml over 100 to 300 msec at pressures from 40 to 200 mm Hg. One hundred forty-five samples were obtained. Flow jet diameter consistently overestimated tube diameter by 2 mm when injected volume was 1.5 to 7 ml and by 1.5 mm when injected volume was less than 1.5 ml. This offset was stable with various transducers (2.5, 3.5, 5.0 MHz) at normal gain setting (just under noise). Therefore, corrected flow jet diameter (FJD) = FJD - 2 mm, and Doppler volume = corrected flow jet area x velocity integral. A range of injectates from 1.1 to 7 ml generated Doppler volume of 1.0 to 8.2 ml. The relation between Doppler volume (DV) and injected volume (IV) was DV = 1.079 IV - 0.22, r2 = 0.945, p less than 0.01. This relation was not altered by tube diameter. Thus a method combining color flow imaging and continuous wave Doppler provides a reliable and accurate measure of in vitro flow volume.
Tarnoki, Adam Domonkos; Tarnoki, David Laszlo; Speer, Gabor; Littvay, Levente; Bata, Pal; Garami, Zsolt; Berczi, Viktor; Karlinger, Kinga
2015-12-01
Decreased thyroid volume has been related to increased prevalence of thyroid cancer. One hundred and fourteen Hungarian adult twin pairs (69 monozygotic, 45 dizygotic) with or without known thyroid disorders underwent thyroid ultrasound. Thickness of the thyroid isthmus was measured at the thickest portion of the gland in the midline using electronic calipers at the time of scanning. Volume of the thyroid lobe was computed according to the following formula: thyroid height*width*depth*correction factor (0.63). Age-, sex-, body mass index- and smoking-adjusted heritability of the thickness of thyroid isthmus was 50% (95% confidence interval [CI], 35 to 66%). Neither left nor right thyroid volume showed additive genetic effects, but shared environments were 68% (95% CI, 48 to 80%) and 79% (95% CI, 72 to 87%), respectively. Magnitudes of monozygotic and dizygotic co-twin correlations were not substantially impacted by the correction of covariates of body mass index and smoking. Unshared environmental effects showed a moderate influence on dependent parameters (24-50%). Our analysis support that familial factors are important for thyroid measures in a general twin population. A larger sample size is needed to show whether this is because of common environmental (e.g. intrauterine effects, regional nutrition habits, iodine supply) or genetic effects.
Fetal brain volumetry through MRI volumetric reconstruction and segmentation
Estroff, Judy A.; Barnewolt, Carol E.; Connolly, Susan A.; Warfield, Simon K.
2013-01-01
Purpose Fetal MRI volumetry is a useful technique but it is limited by a dependency upon motion-free scans, tedious manual segmentation, and spatial inaccuracy due to thick-slice scans. An image processing pipeline that addresses these limitations was developed and tested. Materials and methods The principal sequences acquired in fetal MRI clinical practice are multiple orthogonal single-shot fast spin echo scans. State-of-the-art image processing techniques were used for inter-slice motion correction and super-resolution reconstruction of high-resolution volumetric images from these scans. The reconstructed volume images were processed with intensity non-uniformity correction and the fetal brain extracted by using supervised automated segmentation. Results Reconstruction, segmentation and volumetry of the fetal brains for a cohort of twenty-five clinically acquired fetal MRI scans was done. Performance metrics for volume reconstruction, segmentation and volumetry were determined by comparing to manual tracings in five randomly chosen cases. Finally, analysis of the fetal brain and parenchymal volumes was performed based on the gestational age of the fetuses. Conclusion The image processing pipeline developed in this study enables volume rendering and accurate fetal brain volumetry by addressing the limitations of current volumetry techniques, which include dependency on motion-free scans, manual segmentation, and inaccurate thick-slice interpolation. PMID:20625848
DOE Office of Scientific and Technical Information (OSTI.GOV)
Czarnecki, D; Voigts-Rhetz, P von; Zink, K
2016-06-15
Purpose: The impact of removing the flattening filter on absolute dosimetry based on IAEA’s TPR-398 and AAPM’s TG-51 was investigated in this study using Monte Carlo simulations. Methods: The EGSnrc software package was used for all Monte Carlo simulations performed in this work. Five different ionization chambers and nine linear accelerator heads have been modeled according to technical drawings. To generate a flattening filter free radiation field the flattening filter was replaced by a 2 mm thick aluminum layer. Dose calculation in a water phantom were performed to calculate the beam quality correction factor k{sub Q} as a function ofmore » the beam quality specifiers %dd(10){sub x}, TPR{sub 20,10} and mean photon and electron energies at the point of measurement in photon fields with (WFF) and without flattening filter (FFF). Results: The beam quality correction factor as a function of %dd(10){sub x} differs systematically between FFF and WFF beams for all investigated ionization chambers. The largest difference of 1.8% was observed for the largest investigated Farmer-type ionization chamber with a sensitive volume of 0.69 cm{sup 3}. For ionization chambers with a smaller nominal sensitive volume (0.015 – 0.3 cm{sup 3}) the deviation was less than 0.4% between WFF and FFF beams for %dd(10){sub x} > 62%. The specifier TPR{sub 20,10} revealed only a good correlation between WFF and FFF beams (< 0.3%) for low energies. Conclusion: The results confirm that %dd(10){sub x} is a suitable beam quality specifier for FFF beams with an acceptable bias. The deviation depends on the volume of the ionization chamber. Using %dd(10){sub x} to predict k{sub Q} for a large volume chamber in a FFF photon field may lead to not acceptable errors according to the results of this study. This bias may be caused by the volume effect due to the inhomogeneous photon fields of FFF linear accelerators.« less
Electromagnetic corrections to the hadronic vacuum polarization of the photon within QEDL and QEDM
NASA Astrophysics Data System (ADS)
Bussone, Andrea; Della Morte, Michele; Janowski, Tadeusz
2018-03-01
We compute the leading QED corrections to the hadronic vacuum polarization (HVP) of the photon, relevant for the determination of leptonic anomalous magnetic moments, al. We work in the electroquenched approximation and use dynamical QCD configurations generated by the CLS initiative with two degenerate flavors of nonperturbatively O(a)-improved Wilson fermions. We consider QEDL and QEDM to deal with the finite-volume zero modes. We compare results for the Wilson loops with exact analytical determinations. In addition we make sure that the volumes and photon masses used in QEDM are such that the correct dispersion relation is reproduced by the energy levels extracted from the charged pions two-point functions. Finally we compare results for pion masses and the HVP between QEDL and QEDM. For the vacuum polarization, corrections with respect to the pure QCD case, at fixed pion masses, turn out to be at the percent level.
Zhang, Ying; Alonzo, Todd A
2016-11-01
In diagnostic medicine, the volume under the receiver operating characteristic (ROC) surface (VUS) is a commonly used index to quantify the ability of a continuous diagnostic test to discriminate between three disease states. In practice, verification of the true disease status may be performed only for a subset of subjects under study since the verification procedure is invasive, risky, or expensive. The selection for disease examination might depend on the results of the diagnostic test and other clinical characteristics of the patients, which in turn can cause bias in estimates of the VUS. This bias is referred to as verification bias. Existing verification bias correction in three-way ROC analysis focuses on ordinal tests. We propose verification bias-correction methods to construct ROC surface and estimate the VUS for a continuous diagnostic test, based on inverse probability weighting. By applying U-statistics theory, we develop asymptotic properties for the estimator. A Jackknife estimator of variance is also derived. Extensive simulation studies are performed to evaluate the performance of the new estimators in terms of bias correction and variance. The proposed methods are used to assess the ability of a biomarker to accurately identify stages of Alzheimer's disease. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Abu Anas, Emran Mohammad; Kim, Jae Gon; Lee, Soo Yeol; Kamrul Hasan, Md
2011-10-01
The use of an x-ray flat panel detector is increasingly becoming popular in 3D cone beam volume CT machines. Due to the deficient semiconductor array manufacturing process, the cone beam projection data are often corrupted by different types of abnormalities, which cause severe ring and radiant artifacts in a cone beam reconstruction image, and as a result, the diagnostic image quality is degraded. In this paper, a novel technique is presented for the correction of error in the 2D cone beam projections due to abnormalities often observed in 2D x-ray flat panel detectors. Template images are derived from the responses of the detector pixels using their statistical properties and then an effective non-causal derivative-based detection algorithm in 2D space is presented for the detection of defective and mis-calibrated detector elements separately. An image inpainting-based 3D correction scheme is proposed for the estimation of responses of defective detector elements, and the responses of the mis-calibrated detector elements are corrected using the normalization technique. For real-time implementation, a simplification of the proposed off-line method is also suggested. Finally, the proposed algorithms are tested using different real cone beam volume CT images and the experimental results demonstrate that the proposed methods can effectively remove ring and radiant artifacts from cone beam volume CT images compared to other reported techniques in the literature.
Accurately determining log and bark volumes of saw logs using high-resolution laser scan data
R. Edward Thomas; Neal D. Bennett
2014-01-01
Accurately determining the volume of logs and bark is crucial to estimating the total expected value recovery from a log. Knowing the correct size and volume of a log helps to determine which processing method, if any, should be used on a given log. However, applying volume estimation methods consistently can be difficult. Errors in log measurement and oddly shaped...
Ding, Kan; Gong, Yunhua; Modur, Pradeep N; Diaz-Arrastia, Ramon; Agostini, Mark; Gupta, Puneet; McColl, Roderick; Hays, Ryan; Van Ness, Paul
2016-02-01
The Wada test is widely used in the presurgical evaluation of potential temporal lobectomy patients to predict postoperative memory function. Expected asymmetry (EA), defined as Wada memory lateralized to the nonsurgical hemisphere, or a higher score after injection of the surgical hemisphere would be considered favorable in terms of postoperative memory outcome. However, in some cases, nonlateralized memory (NM) results, with no appreciable asymmetry, may occur because of impaired scores after both injections, often leading to denial of surgery. The reason for such nonlateralized Wada memory in patients with intractable temporal lobe epilepsy (TLE) remains unclear. Given that quantitative morphometric magnetic resonance imaging studies in TLE patients have shown bilateral regional atrophy in temporal and extratemporal structures, we hypothesized that the volume loss in contralateral temporal structures could contribute to nonlateralized Wada memory performance. To investigate this, we examined the relationship between the volume changes of temporal structures and Wada memory scores in patients with intractable TLE with mesial temporal sclerosis (MTS) using an age- and gender-matched control group. Memory was considered nonlateralized if the absolute difference in the total correct recall scores between ipsilateral and contralateral injections was <11%. Among 21 patients, Wada memory was lateralized in 15 and nonlateralized in 6 patients, with all the nonlateralized scores being observed in left TLE. The recall scores after ipsilateral injection were significantly lower in patients with an NM profile than an EA profile (23 ± 14% vs. 59 ± 18% correct recall, p ≤ 0.001). However, the recall scores after contralateral injection were low but similar between the two groups (25 ± 17% vs. 25 ± 15% correct recall, p=0.97). Compared to controls, all the patients showed greater volume loss in the temporal regions. However, patients with a NM profile showed significantly more volume loss than those with a lateralized memory profile in both contralateral and ipsilateral temporal regions (p<0.05). Left hemispheric Wada memory performance correlated positively with the size of the left mesial and neocortical temporal structures (r=0.49-0.63, p=0.005-0.04). Our study suggests that volume loss in the nonsurgical temporal structures is associated with nonlateralized Wada memory results in patients with intractable TLE. Copyright © 2015 Elsevier B.V. All rights reserved.
Dahlgren, Björn; Reif, Maria M; Hünenberger, Philippe H; Hansen, Niels
2012-10-09
The raw ionic solvation free energies calculated on the basis of atomistic (explicit-solvent) simulations are extremely sensitive to the boundary conditions and treatment of electrostatic interactions used during these simulations. However, as shown recently [Kastenholz, M. A.; Hünenberger, P. H. J. Chem. Phys.2006, 124, 224501 and Reif, M. M.; Hünenberger, P. H. J. Chem. Phys.2011, 134, 144104], the application of an appropriate correction scheme allows for a conversion of the methodology-dependent raw data into methodology-independent results. In this work, methodology-independent derivative thermodynamic hydration and aqueous partial molar properties are calculated for the Na(+) and Cl(-) ions at P° = 1 bar and T(-) = 298.15 K, based on the SPC water model and on ion-solvent Lennard-Jones interaction coefficients previously reoptimized against experimental hydration free energies. The hydration parameters considered are the hydration free energy and enthalpy. The aqueous partial molar parameters considered are the partial molar entropy, volume, heat capacity, volume-compressibility, and volume-expansivity. Two alternative calculation methods are employed to access these properties. Method I relies on the difference in average volume and energy between two aqueous systems involving the same number of water molecules, either in the absence or in the presence of the ion, along with variations of these differences corresponding to finite pressure or/and temperature changes. Method II relies on the calculation of the hydration free energy of the ion, along with variations of this free energy corresponding to finite pressure or/and temperature changes. Both methods are used considering two distinct variants in the application of the correction scheme. In variant A, the raw values from the simulations are corrected after the application of finite difference in pressure or/and temperature, based on correction terms specifically designed for derivative parameters at P° and T(-). In variant B, these raw values are corrected prior to differentiation, based on corresponding correction terms appropriate for the different simulation pressures P and temperatures T. The results corresponding to the different calculation schemes show that, except for the hydration free energy itself, accurate methodological independence and quantitative agreement with even the most reliable experimental parameters (ion-pair properties) are not yet reached. Nevertheless, approximate internal consistency and qualitative agreement with experimental results can be achieved, but only when an appropriate correction scheme is applied, along with a careful consideration of standard-state issues. In this sense, the main merit of the present study is to set a clear framework for these types of calculations and to point toward directions for future improvements, with the ultimate goal of reaching a consistent and quantitative description of single-ion hydration thermodynamics in molecular dynamics simulations.
Murphy, Clodagh M; Deeley, Q; Daly, E M; Ecker, C; O'Brien, F M; Hallahan, B; Loth, E; Toal, F; Reed, S; Hales, S; Robertson, D M; Craig, M C; Mullins, D; Barker, G J; Lavender, T; Johnston, P; Murphy, K C; Murphy, D G
2012-02-01
It has been proposed that people with autism spectrum disorder (ASD) have abnormal morphometry and development of the amygdala and hippocampus (AH). However, previous reports are inconsistent, perhaps because they included people of different ASD diagnoses, ages, and health. We compared, using magnetic resonance imaging, the in vivo anatomy of the AH in 32 healthy individuals with Asperger syndrome (12-47 years) and 32 healthy controls who did not differ significantly in age or IQ. We measured bulk (gray + white matter) volume of the AH using manual tracing (MEASURE). We first compared the volume of AH between individuals with Asperger syndrome and controls and then investigated age-related differences. We compared differences in anatomy before, and after, correcting for whole brain size. There was no significant between group differences in whole brain volume. However, individuals with Asperger syndrome had a significantly larger raw bulk volume of total (P<0.01), right (P<0.01), and left amygdala (P<0.05); and when corrected for overall brain size, total (P<0.05), and right amygdala (P<0.01). There was a significant group difference in aging of left amygdala; controls, but not individuals with Asperger syndrome, had a significant age-related increase in volume (r = 0.486, P<0.01, and r = 0.007, P = 0.97, z = 1.995). There were no significant group differences in volume or age-related effects in hippocampus. Individuals with Asperger syndrome have significant differences from controls in bulk volume and aging of the amygdala. Copyright © 2011, International Society for Autism Research, Wiley-Liss, Inc.
Goldman, Mitchel P; Moradi, Amir; Gold, Michael H; Friedmann, Daniel P; Alizadeh, Kaveh; Adelglass, Jeffrey M; Katz, Bruce E
2018-01-01
Calcium hydroxylapatite (CaHA) microspheres suspended in a carrier gel is an opaque dermal filler that has been used to provide immediate volume correction in the dorsal hands. To assess the safety and effectiveness of CaHA for the correction of volume loss in the hands up to 12 months. This multicenter, controlled, single-blind study (NCT01832090) included 114 subjects randomized 3:1 to CaHA treatment and untreated control groups. Effectiveness was assessed by blinded investigators using the validated Merz Hand Grading Scale (MHGS). Subject-reported improvement was assessed using the Global Aesthetic Improvement Scale. Effects of treatment on hand function were also assessed. A total of 75% of subjects achieved ≥1-point improvement on the MHGS (p < .0001) at 3 months (primary end point); this response was generally maintained through 12 months. Proportions of subjects reporting improvement ranged from 98% (3 months) to 86% (12 months). There were no clinically significant differences between control and CaHA-treated subjects in any hand function measure. Adverse events were generally expected, minor, short-lived, injection-related, and similar to those observed in previous CaHA clinical studies. Treatment with CaHA results in significant improvement in the appearance of the dorsal hand and is well tolerated.
Bernardini, Francesco P; Gennai, Alessandro; Izzo, Luigi; Zambelli, Alessandra; Repaci, Erica; Baldelli, Ilaria; Fraternali-Orcioni, G; Hartstein, Morris E; Santi, Pier Luigi; Quarto, Rodolfo
2015-07-01
Although recent research on micro fat has shown the potential advantages of superficial implantation and high stem cell content, clinical applications thus far have been limited. The authors report their experience with superficial enhanced fluid fat injection (SEFFI) for the correction of volume loss and skin aging of the face in general and in the periocular region. The finer SEFFI preparation (0.5 mL) was injected into the orbicularis in the periorbital and perioral areas, and the 0.8-mL preparation was injected subdermally elsewhere in the face. The records of 98 consecutive patients were reviewed. Average follow-up time was 6 months, and average volume of implanted fat was 20 mL and 51.4 mL for the 0.5-mL and 0.8-mL preparations, respectively. Good or excellent results were achieved for volume restoration and skin improvement in all patients. Complications were minor and included an oil cyst in 3 patients. The smaller SEFFI quantity (0.5 mL) was well suited to correct volume loss in the eyelids, especially the deep upper sulcus and tear trough, whereas the larger SEFFI content was effective for larger volume deficits in other areas of the face, including the brow, temporal fossa, zygomatic-malar region, nasolabial folds, marionette lines, chin, and lips. The fat administered by SEFFI is easily harvested via small side-port cannulae, yielding micro fat that is rich in viable adipocytes and stem cells. Both volumes of fat (0.5 mL and 0.8 mL) were effective for treating age-related lipoatrophy, reducing facial rhytids, and improving skin quality. 4 Therapeutic. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.
Use, misuse and abuse of diuretics.
Bartoli, Ettore; Rossi, Luca; Sola, Daniele; Castello, Luigi; Sainaghi, Pier Paolo; Smirne, Carlo
2017-04-01
Resolution of edema requires a correct interpretation of body fluids-related renal function, to excrete the excess volume while restoring systemic hemodynamics and avoiding renal failure. In heart failure, the intensive diuresis should be matched by continuous fluids refeeding from interstitium to plasma, avoiding central volume depletion. The slowly reabsorbed ascites cannot refeed this contracted volume in cirrhosis: the ensuing activation of intrathoracic receptors, attended by increased adrenergic and Renin release, causes more avid sodium retention, producing a positive fluid and Na balance in the face of continuous treatment. High-dose-furosemide creates a defect in tubular Na causing diuresis adequate to excrete the daily water and electrolyte load in Chronic Renal Failure. Diuretic treatment requires care, caution and bedside "tricks" aimed at minimizing volume contraction by correctly assessing the homeostatic system of body fluids and related renal hemodynamics. Copyright © 2017 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.
Contracting for Correctional Services in the Community. Volume I: Summary.
ERIC Educational Resources Information Center
Kassebaum, Gene; And Others
To describe and analyze the use of private organizations for supervision, training, or assistance of persons referred from criminal justice agencies was the purpose of this study. Procedures were divided into three parts: a review of relevant existing published data and, to the extent possible, ongoing studies; a survey of a national sample of…
Shimizu, Kazuhiro; Kosaka, Nobuyuki; Fujiwara, Yasuhiro; Matsuda, Tsuyoshi; Yamamoto, Tatsuya; Tsuchida, Tatsuro; Tsuchiyama, Katsuki; Oyama, Nobuyuki; Kimura, Hirohiko
2017-01-10
The importance of arterial transit time (ATT) correction for arterial spin labeling MRI has been well debated in neuroimaging, but it has not been well evaluated in renal imaging. The purpose of this study was to evaluate the feasibility of pulsed continuous arterial spin labeling (pcASL) MRI with multiple post-labeling delay (PLD) acquisition for measuring ATT-corrected renal blood flow (ATC-RBF). A total of 14 volunteers were categorized into younger (n = 8; mean age, 27.0 years) and older groups (n = 6; 64.8 years). Images of pcASL were obtained at three different PLDs (0.5, 1.0, and 1.5 s), and ATC-RBF and ATT were calculated using a single-compartment model. To validate ATC-RBF, a comparative study of effective renal plasma flow (ERPF) measured by 99m Tc-MAG3 scintigraphy was performed. ATC-RBF was corrected by kidney volume (ATC-cRBF) for comparison with ERPF. The younger group showed significantly higher ATC-RBF (157.68 ± 38.37 mL/min/100 g) and shorter ATT (961.33 ± 260.87 ms) than the older group (117.42 ± 24.03 mL/min/100 g and 1227.94 ± 226.51 ms, respectively; P < 0.05). A significant correlation was evident between ATC-cRBF and ERPF (P < 0.05, r = 0.47). With suboptimal single PLD (1.5 s) settings, there was no significant correlation between ERPF and kidney volume-corrected RBF calculated from single PLD data. Calculation of ATT and ATC-RBF by pcASL with multiple PLD was feasible in healthy volunteers, and differences in ATT and ATC-RBF were seen between the younger and older groups. Although ATT correction by multiple PLD acquisitions may not always be necessary for RBF quantification in the healthy subjects, the effect of ATT should be taken into account in renal ASL-MRI as debated in brain imaging.
LANDSAT-D data format control book. Volume 6: (Products)
NASA Technical Reports Server (NTRS)
Kabat, F.
1981-01-01
Four basic product types are generated from the raw thematic mapper (TM) and multispectral scanner (MSS) payload data by the NASA GSFC LANDSAT 4 data management system: (1) unprocessed data (raw sensor data); (2) partially processed data, which consists of radiometrically corrected sensor data with geometric correction information appended; (3) fully processed data, which consists of radiometrically and geometrically corrected sensor data; and (4) inventory data which consists of summary information about product types 2 and 3. High density digital recorder formatting and the radiometric correction process are described. Geometric correction information is included.
Theories on Criminality and Mental Retardation Project CAMIO, Volume 2.
ERIC Educational Resources Information Center
Haskins, Jimmy R.; Friel, Charles M.
This historical review of theories on criminality and mental retardation is part of Project CAMIO (Correctional Administration and the Mentally Incompetent Offender), a Texas study to determine the incidence of criminal incarceration of the mentally retarded (MR) and to identify laws, procedures, and practices which affect the prosecution and…
Middle School Students' Reasoning in Nonlinear Proportional Problems in Geometry
ERIC Educational Resources Information Center
Ayan, Rukiye; Isiksal Bostan, Mine
2018-01-01
In this study, we investigate sixth, seventh, and eighth grade students' achievement in nonlinear (quadratic or cubic) proportional problems regarding length, area, and volume of enlarged figures. In addition, we examine students' solution strategies for the problems and obstacles that prevent students from answering the problems correctly by…
American Indian Literature. A Selected Bibliography for Iowa Schools.
ERIC Educational Resources Information Center
Bataille, Gretchen Mueller
Avoidance of stereotypes and realistic portrayal of American Indian life are among the criteria used for the references included in this annotated bibliography. The volume is intended to assist Iowa teachers, particularly of language arts and social studies, in correcting misconceptions about American Indians by identifying materials and resources…
Inoue, Kentaro; Ito, Hiroshi; Goto, Ryoi; Nakagawa, Manabu; Kinomura, Shigeo; Sato, Tachio; Sato, Kazunori; Fukuda, Hiroshi
2005-06-01
Several studies using single photon emission tomography (SPECT) have shown changes in cerebral blood flow (CBF) with age, which were associated with partial volume effects by some authors. Some studies have also demonstrated gender-related differences in CBF. The present study aimed to examine age and gender effects on CBF SPECT images obtained using the 99mTc-ethyl cysteinate dimer and a SPECT scanner, before and after partial volume correction (PVC) using magnetic resonance (MR) imaging. Forty-four healthy subjects (29 males and 15 females; age range, 27-64 y; mean age, 50.0 +/- 9.8 y) participated. Each MR image was segmented to yield grey and white matter images and coregistered to a corresponding SPECT image, followed by convolution to approximate the SPECT spatial resolution. PVC-SPECT images were produced using the convoluted grey matter MR (GM-MR) and white matter MR images. The age and gender effects were assessed using SPM99. Decreases with age were detected in the anterolateral prefrontal cortex and in areas along the lateral sulcus and the lateral ventricle, bilaterally, in the GM-MR images and the SPECT images. In the PVC-SPECT images, decreases in CBF in the lateral prefrontal cortex lost their statistical significance. Decreases in CBF with age found along the lateral sulcus and the lateral ventricle, on the other hand, remained statistically significant, but observation of the spatially normalized MR images suggests that these findings are associated with the dilatation of the lateral sulcus and lateral ventricle, which was not completely compensated for by the spatial normalization procedure. Our present study demonstrated that age effects on CBF in healthy subjects could reflect morphological differences with age in grey matter.
Brunet-Benkhoucha, M; Verhaegen, F; Lassalle, S; Béliveau-Nadeau, D; Reniers, B; Donath, D; Taussky, D; Carrier, J-F
2008-07-01
To develop a tomosynthesis-based dose assessment procedure that can be performed after an I-125 prostate seed implantation, while the patient is still under anaesthesia on the treatment table. Our seed detection procedure involves the reconstruction of a volume of interest based on the backprojection of 7 seed-only binary images acquired over an angle of 60° with an isocentric imaging system. A binary seed-only volume is generated by a simple thresholding of the volume of interest. Seeds positions are extracted from this volume with a 3D connected component analysis and a statistical classifier that determines the number of seeds in each cluster of connected voxels. A graphical user interface (GUI) allows to visualize the result and to introduce corrections, if needed. A phantom and a clinical study (24 patients) were carried out to validate the technique. A phantom study demonstrated a very good localization accuracy of (0.4+/-0.4) mm when compared to CT-based reconstruction. This leads to dosimetric error on D90 and V100 of respectively 0.5% and 0.1%. In a patient study with an average of 56 seeds per implant, the automatic tomosynthesis-based reconstruction yields a detection rate of 96% of the seeds and less than 1.5% of false-positives. With the help of the GUI, the user can achieve a 100% detection rate in an average of 3 minutes. This technique would allow to identify possible underdosage and to correct it by potentially reimplanting additional seeds. A more uniform dose coverage could then be achieved in LDR prostate brachytherapy. © 2008 American Association of Physicists in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Water, Steven van de, E-mail: s.vandewater@erasmusmc.nl; Valli, Lorella; Alma Mater Studiorum, Department of Physics and Astronomy, Bologna University, Bologna
Purpose: To investigate the dosimetric impact of intrafraction prostate motion and the effect of robot correction strategies for hypofractionated CyberKnife treatments with a simultaneously integrated boost. Methods and Materials: A total of 548 real-time prostate motion tracks from 17 patients were available for dosimetric simulations of CyberKnife treatments, in which various correction strategies were included. Fixed time intervals between imaging/correction (15, 60, 180, and 360 seconds) were simulated, as well as adaptive timing (ie, the time interval reduced from 60 to 15 seconds in case prostate motion exceeded 3 mm or 2° in consecutive images). The simulated extent of robot corrections was alsomore » varied: no corrections, translational corrections only, and translational corrections combined with rotational corrections up to 5°, 10°, and perfect rotational correction. The correction strategies were evaluated for treatment plans with a 0-mm or 3-mm margin around the clinical target volume (CTV). We recorded CTV coverage (V{sub 100%}) and dose-volume parameters of the peripheral zone (boost), rectum, bladder, and urethra. Results: Planned dose parameters were increasingly preserved with larger extents of robot corrections. A time interval between corrections of 60 to 180 seconds provided optimal preservation of CTV coverage. To achieve 98% CTV coverage in 98% of the treatments, translational and rotational corrections up to 10° were required for the 0-mm margin plans, whereas translational and rotational corrections up to 5° were required for the 3-mm margin plans. Rectum and bladder were spared considerably better in the 0-mm margin plans. Adaptive timing did not improve delivered dose. Conclusions: Intrafraction prostate motion substantially affected the delivered dose but was compensated for effectively by robot corrections using a time interval of 60 to 180 seconds. A 0-mm margin required larger extents of additional rotational corrections than a 3-mm margin but resulted in lower doses to rectum and bladder.« less
Yang, Mingyuan; Li, Chao; Li, Yanming; Zhao, Yingchuan; Wei, Xianzhao; Zhang, Guoyou; Fan, Jianping; Ni, Haijian; Chen, Ziqiang; Bai, Yushu; Li, Ming
2015-01-01
Abstract A retrospective study to evaluate the effectiveness of 3-dimensional rapid prototyping (3DRP) technology in corrective surgery for Lenke 1 adolescent idiopathic scoliosis (AIS) patients. 3DRP technology has been widely used in medical field; however, no study has been performed on the effectiveness of 3DRP technology in corrective surgery for Lenke 1 AIS patients. Lenke 1 AIS patients who were preparing to undergo posterior corrective surgery from a single center between January 2010 and January 2012 were included in this analysis. Patients were divided into 2 groups. In group A, 3-dimensional (3D) printing technology was used to create subject-specific spine models in the preoperative planning process. Group B underwent posterior corrective surgery as usual (by free hand without image guidance). Perioperative and postoperative clinical outcomes were compared between 2 groups, including operation time, perioperative blood loss, transfusion volume, postoperative hemoglobin (Hb), postoperative complications, and length of hospital stay. Radiological outcomes were also compared, including the assessment of screw placement, postoperative Cobb angle, coronal balance, sagittal vertical axis, thoracic kyphosis, and lumbar lordosis. Subgroup was also performed according to the preoperative Cobb angle: mean Cobb angle <50° and mean Cobb angle >50°. Besides, economic evaluation was also compared between 2 groups. A total of 126 patients were included in this study (group A, 50 and group B, 76). Group A had significantly shorter operation time, significantly less blood loss and transfusion volume, and higher postoperative Hb (all, P < 0.001). However, no significant differences were observed in complication rate, length of hospital stay, and postoperative radiological outcomes between 2 groups (all, P>0.05). There was also no significant difference in misplacement of screws in total populations (16.90% vs 18.82%, P = 0.305), whereas a low misplacement rate of pedicle screws was observed in patients whose mean Cobb angle was >50° (9.15% vs 13.03%, P = 0.02). Besides, using 3DRP increased the economic burden of patients (157,000 ± 9948.85 Ren Min Bi (RMB) vs 152,500 ± 11,445.52 RMB, P = 0.03). Using the 3D printing technology before posterior corrective surgery might reduce the operation time, perioperative blood loss, and transfusion volume. There did not appear to be a benefit to using this technology with respect to complication rate and postoperative radiological outcomes; however, 3D technology could reduce the misplacement rate in patients whose preoperative mean Cobb angle was >50°. Besides, it also increased the patients’ hospital cost. Therefore, future prospective studies are needed to elucidate the efficacy of this emerging technology. PMID:25715261
Alcohol consumption during adolescence is associated with reduced grey matter volumes.
Heikkinen, Noora; Niskanen, Eini; Könönen, Mervi; Tolmunen, Tommi; Kekkonen, Virve; Kivimäki, Petri; Tanila, Heikki; Laukkanen, Eila; Vanninen, Ritva
2017-04-01
Cognitive impairment has been associated with excessive alcohol use, but its neural basis is poorly understood. Chronic excessive alcohol use in adolescence may lead to neuronal loss and volumetric changes in the brain. Our objective was to compare the grey matter volumes of heavy- and light-drinking adolescents. This was a longitudinal study: heavy-drinking adolescents without an alcohol use disorder and their light-drinking controls were followed-up for 10 years using questionnaires at three time-points. Magnetic resonance imaging was conducted at the last time-point. The area near Kuopio University Hospital, Finland. The 62 participants were aged 22-28 years and included 35 alcohol users and 27 controls who had been followed-up for approximately 10 years. Alcohol use was measured by the Alcohol Use Disorders Identification Test (AUDIT)-C at three time-points during 10 years. Participants were selected based on their AUDIT-C score. Magnetic resonance imaging was conducted at the last time-point. Grey matter volume was determined and compared between heavy- and light-drinking groups using voxel-based morphometry on three-dimensional T1-weighted magnetic resonance images using predefined regions of interest and a threshold of P < 0.05, with small volume correction applied on cluster level. Grey matter volumes were significantly smaller among heavy-drinking participants in the bilateral anterior cingulate cortex, right orbitofrontal and frontopolar cortex, right superior temporal gyrus and right insular cortex compared to the control group (P < 0.05, family-wise error-corrected cluster level). Excessive alcohol use during adolescence appears to be associated with an abnormal development of the brain grey matter. Moreover, the structural changes detected in the insula of alcohol users may reflect a reduced sensitivity to alcohol's negative subjective effects. © 2016 Society for the Study of Addiction.
Rowe, William J
2010-01-01
Since pharmaceuticals cannot be used in space until liver and kidney dysfunctions are corrected, and with invariable malabsorption, it appears there is no alternative other than to use subcutaneous magnesium (Mg) replacements in the presence of deficiencies and use of gene therapy. I suggest beginning with the correction of as many as four gene deficiencies: atrial natriuretic peptide (ANP), nitric oxide (NO), vascular endothelial growth factor (VEGF), and erythropoietin (EPO), all as well as Mg related to perfusion and angiogenesis. There is no evidence of significant lunar radiation levels in the absence of a solar storm. It could then be determined whether this has resulted in correction of liver and kidney dysfunction. If this persists, serial additions of gene therapy will be required determining the effect of each individual gene trial on organ function. Microgravity and endothelial gaps with leaks trigger reduced plasma volume. Partial correction by use of a plasma volume substitute and development of a delivery device may reduce complexity of gene therapy. Research would be conducted both on Earth and in microgravity, with the development of subcutaneous pharmaceuticals and Mg, and a space walk-reliable subcutaneous silicon device, given that no replenishable subcutaneous device is presently available. A three-pronged approach provides a plan for the next 50 years: A. complete correction of a Mg deficit; B. partial replacement with plasma volume substitutes, and C. multiple gene factor strategy. PMID:21694938
Rowe, William J
2010-01-01
Since pharmaceuticals cannot be used in space until liver and kidney dysfunctions are corrected, and with invariable malabsorption, it appears there is no alternative other than to use subcutaneous magnesium (Mg) replacements in the presence of deficiencies and use of gene therapy. I suggest beginning with the correction of as many as four gene deficiencies: atrial natriuretic peptide (ANP), nitric oxide (NO), vascular endothelial growth factor (VEGF), and erythropoietin (EPO), all as well as Mg related to perfusion and angiogenesis. There is no evidence of significant lunar radiation levels in the absence of a solar storm. It could then be determined whether this has resulted in correction of liver and kidney dysfunction. If this persists, serial additions of gene therapy will be required determining the effect of each individual gene trial on organ function. Microgravity and endothelial gaps with leaks trigger reduced plasma volume. Partial correction by use of a plasma volume substitute and development of a delivery device may reduce complexity of gene therapy. Research would be conducted both on Earth and in microgravity, with the development of subcutaneous pharmaceuticals and Mg, and a space walk-reliable subcutaneous silicon device, given that no replenishable subcutaneous device is presently available. A three-pronged approach provides a plan for the next 50 years: A. complete correction of a Mg deficit; B. partial replacement with plasma volume substitutes, and C. multiple gene factor strategy. 2010 Halvorson et al, publisher and licensee Dove Medical Press Ltd.
NASA Technical Reports Server (NTRS)
Leibfried, T. F., Jr.; Davari, Sadegh; Natarajan, Swami; Zhao, Wei
1992-01-01
Two categories were chosen for study: the issue of using a preprocessor on Ada code of Application Programs which would interface with the Run-Time Object Data Base Standard Services (RODB STSV), the intent was to catch and correct any mis-registration errors of the program coder between the user declared Objects, their types, their addresses, and the corresponding RODB definitions; and RODB STSV Performance Issues and Identification of Problems with the planned methods for accessing Primitive Object Attributes, this included the study of an alternate storage scheme to the 'store objects by attribute' scheme in the current design of the RODB. The study resulted in essentially three separate documents, an interpretation of the system requirements, an assessment of the preliminary design, and a detailing of the components of a detailed design.
Palazzuoli, Alberto; Silverberg, Donald S; Calabrò, Anna; Spinelli, Tommaso; Quatrini, Ilaria; Campagna, Maria S; Franci, Beatrice; Nuti, Ranuccio
2009-06-01
Anemia in heart failure is related to advanced New York Heart Association classes, severe systolic dysfunction, and reduced exercise tolerance. Although anemia is frequently found in congestive heart failure (CHF), little is known about the effect of its' correction with erythropoietin (EPO) on cardiac structure and function. The present study examines, in patients with advanced CHF and anemia, the effects of beta-EPO on left ventricular volumes, left ventricular ejection fraction (LVEF), left and right longitudinal function mitral anular plane systolic excursion (MAPSE), tricuspid anular plane excursion (TAPSE), and pulmonary artery pressures in 58 patients during 1-year follow-up in a double-blind controlled study of correction of anemia with subcutaneous beta-EPO. Echocardiographic evaluation, B-Type natriuretic peptide (BNP) levels, and hematological parameters are reported at 4 and 12 months. The patients in group A after 4 months of follow-up period demonstrated an increase in LVEF and MAPSE (P < 0.05 and P < 0.01, respectively) with left ventricular systolic volume reduction (P < 0.02) with respect to baseline and controls. After 12 months, results regarding left ventricular systolic volume LVEF and MAPSE persisted (P < 0.001). In addition, TAPSE increased and pulmonary artery pressures fell significantly in group A (P < 0.01). All these changes occurred together with a significant BNP reduction and significant hemoglobin increase in the treated group. Therefore, we revealed a reduced hospitalization rate in treated patients with respect to the controls (25% in treated vs. 54% in controls). In patients with anemia and CHF, correction of anemia with beta-EPO and oral iron over 1 year leads to an improvement in left and right ventricular systolic function by reducing cardiac remodeling, BNP levels, and hospitalization rate.
Automatic detection of cardiovascular risk in CT attenuation correction maps in Rb-82 PET/CTs
NASA Astrophysics Data System (ADS)
Išgum, Ivana; de Vos, Bob D.; Wolterink, Jelmer M.; Dey, Damini; Berman, Daniel S.; Rubeaux, Mathieu; Leiner, Tim; Slomka, Piotr J.
2016-03-01
CT attenuation correction (CTAC) images acquired with PET/CT visualize coronary artery calcium (CAC) and enable CAC quantification. CAC scores acquired with CTAC have been suggested as a marker of cardiovascular disease (CVD). In this work, an algorithm previously developed for automatic CAC scoring in dedicated cardiac CT was applied to automatic CAC detection in CTAC. The study included 134 consecutive patients undergoing 82-Rb PET/CT. Low-dose rest CTAC scans were acquired (100 kV, 11 mAs, 1.4mm×1.4mm×3mm voxel size). An experienced observer defined the reference standard with the clinically used intensity level threshold for calcium identification (130 HU). Five scans were removed from analysis due to artifacts. The algorithm extracted potential CAC by intensity-based thresholding and 3D connected component labeling. Each candidate was described by location, size, shape and intensity features. An ensemble of extremely randomized decision trees was used to identify CAC. The data set was randomly divided into training and test sets. Automatically identified CAC was quantified using volume and Agatston scores. In 33 test scans, the system detected on average 469mm3/730mm3 (64%) of CAC with 36mm3 false positive volume per scan. The intraclass correlation coefficient for volume scores was 0.84. Each patient was assigned to one of four CVD risk categories based on the Agatston score (0-10, 11-100, 101-400, <400). The correct CVD category was assigned to 85% of patients (Cohen's linearly weighted κ0.82). Automatic detection of CVD risk based on CAC scoring in rest CTAC images is feasible. This may enable large scale studies evaluating clinical value of CAC scoring in CTAC data.
Improved correction for the tissue fraction effect in lung PET/CT imaging
NASA Astrophysics Data System (ADS)
Holman, Beverley F.; Cuplov, Vesna; Millner, Lynn; Hutton, Brian F.; Maher, Toby M.; Groves, Ashley M.; Thielemans, Kris
2015-09-01
Recently, there has been an increased interest in imaging different pulmonary disorders using PET techniques. Previous work has shown, for static PET/CT, that air content in the lung influences reconstructed image values and that it is vital to correct for this ‘tissue fraction effect’ (TFE). In this paper, we extend this work to include the blood component and also investigate the TFE in dynamic imaging. CT imaging and PET kinetic modelling are used to determine fractional air and blood voxel volumes in six patients with idiopathic pulmonary fibrosis. These values are used to illustrate best and worst case scenarios when interpreting images without correcting for the TFE. In addition, the fractional volumes were used to determine correction factors for the SUV and the kinetic parameters. These were then applied to the patient images. The kinetic parameters K1 and Ki along with the static parameter SUV were all found to be affected by the TFE with both air and blood providing a significant contribution to the errors. Without corrections, errors range from 34-80% in the best case and 29-96% in the worst case. In the patient data, without correcting for the TFE, regions of high density (fibrosis) appeared to have a higher uptake than lower density (normal appearing tissue), however this was reversed after air and blood correction. The proposed correction methods are vital for quantitative and relative accuracy. Without these corrections, images may be misinterpreted.
Determination of fractional flow reserve (FFR) based on scaling laws: a simulation study
NASA Astrophysics Data System (ADS)
Wong, Jerry T.; Molloi, Sabee
2008-07-01
Fractional flow reserve (FFR) provides an objective physiological evaluation of stenosis severity. A technique that can measure FFR using only angiographic images would be a valuable tool in the cardiac catheterization laboratory. To perform this, the diseased blood flow can be measured with a first pass distribution analysis and the theoretical normal blood flow can be estimated from the total coronary arterial volume based on scaling laws. A computer simulation of the coronary arterial network was used to gain a better understanding of how hemodynamic conditions and coronary artery disease can affect blood flow, arterial volume and FFR estimation. Changes in coronary arterial flow and volume due to coronary stenosis, aortic pressure and venous pressure were examined to evaluate the potential use of flow and volume for FFR determination. This study showed that FFR can be estimated using arterial volume and a scaling coefficient corrected for aortic pressure. However, variations in venous pressure were found to introduce some error in FFR estimation. A relative form of FFR was introduced and was found to cancel out the influence of pressure on coronary flow, arterial volume and FFR estimation. The use of coronary flow and arterial volume for FFR determination appears promising.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christiansen, E; Belec, J; Vandervoort, E
2015-06-15
Purpose: To calculate using Monte-Carlo the intermediate and total correction factors (CFs) for two microchambers and a plastic scintillator for composite fields delivered by the CyberKnife system. Methods: A linac model was created in BEAMnrc by matching percentage depth dose (PDD) curves and output factors (OFs) measured using an A16 microchamber with Monte Carlo calculations performed in egs-chamber to explicitly model detector response. Intermediate CFs were determined for the A16 and A26 microchambers and the W1 plastic scintillator in fourteen different composite fields inside a solid water phantom. Seven of these fields used a 5 mm diameter collimator; the remainingmore » fields employed a 7.5 mm collimator but were otherwise identical to the first seven. Intermediate CFs are reported relative to the respective CF for a 60 mm collimator (800 mm source to detector distance and 100 mm depth in water). Results: For microchambers in composite fields, the intermediate CFs that account for detector density and volume were the largest contributors to total CFs. The total CFs for the A26 were larger than those for the A16, especially for the 5 mm cone (1.227±0.003 to 1.144±0.004 versus 1.142±0.003 to 1.099±0.004), due to the A26’s larger active volume (0.015 cc) relative to the A16 (0.007 cc), despite the A26 using similar wall and electrode material. The W1 total and intermediate CFs are closer to unity, due to its smaller active volume and near water-equivalent composition, however, 3–4% detector volume corrections are required for 5 mm collimator fields. In fields using the 7.5 mm collimator, the correction is nearly eliminated for the W1 except for a non-isocentric field. Conclusion: Large and variable CFs are required for microchambers in small composite fields primarily due to density and volume effects. Corrections are reduced but not eliminated for a plastic scintillator in the same fields.« less
Finite-volume and partial quenching effects in the magnetic polarizability of the neutron
NASA Astrophysics Data System (ADS)
Hall, J. M. M.; Leinweber, D. B.; Young, R. D.
2014-03-01
There has been much progress in the experimental measurement of the electric and magnetic polarizabilities of the nucleon. Similarly, lattice QCD simulations have recently produced dynamical QCD results for the magnetic polarizability of the neutron approaching the chiral regime. In order to compare the lattice simulations with experiment, calculation of partial quenching and finite-volume effects is required prior to an extrapolation in quark mass to the physical point. These dependencies are described using chiral effective field theory. Corrections to the partial quenching effects associated with the sea-quark-loop electric charges are estimated by modeling corrections to the pion cloud. These are compared to the uncorrected lattice results. In addition, the behavior of the finite-volume corrections as a function of pion mass is explored. Box sizes of approximately 7 fm are required to achieve a result within 5% of the infinite-volume result at the physical pion mass. A variety of extrapolations are shown at different box sizes, providing a benchmark to guide future lattice QCD calculations of the magnetic polarizabilities. A relatively precise value for the physical magnetic polarizability of the neutron is presented, βn=1.93(11)stat(11)sys×10-4 fm3, which is in agreement with current experimental results.
Further applications of Archimedes' principle in the correction of asymmetrical breasts.
Schultz, R C; Dolezal, R F; Nolan, J
1986-02-01
Archimedes' law of buoyancy has been extended to the preoperative bedside assessment of volume differences between breasts, whatever their cause. The simple method described has proved to be a helpful aid in surgical procedures for the correction of breast asymmetry.
MR-assisted PET Motion Correction for eurological Studies in an Integrated MR-PET Scanner
Catana, Ciprian; Benner, Thomas; van der Kouwe, Andre; Byars, Larry; Hamm, Michael; Chonde, Daniel B.; Michel, Christian J.; El Fakhri, Georges; Schmand, Matthias; Sorensen, A. Gregory
2011-01-01
Head motion is difficult to avoid in long PET studies, degrading the image quality and offsetting the benefit of using a high-resolution scanner. As a potential solution in an integrated MR-PET scanner, the simultaneously acquired MR data can be used for motion tracking. In this work, a novel data processing and rigid-body motion correction (MC) algorithm for the MR-compatible BrainPET prototype scanner is described and proof-of-principle phantom and human studies are presented. Methods To account for motion, the PET prompts and randoms coincidences as well as the sensitivity data are processed in the line or response (LOR) space according to the MR-derived motion estimates. After sinogram space rebinning, the corrected data are summed and the motion corrected PET volume is reconstructed from these sinograms and the attenuation and scatter sinograms in the reference position. The accuracy of the MC algorithm was first tested using a Hoffman phantom. Next, human volunteer studies were performed and motion estimates were obtained using two high temporal resolution MR-based motion tracking techniques. Results After accounting for the physical mismatch between the two scanners, perfectly co-registered MR and PET volumes are reproducibly obtained. The MR output gates inserted in to the PET list-mode allow the temporal correlation of the two data sets within 0.2 s. The Hoffman phantom volume reconstructed processing the PET data in the LOR space was similar to the one obtained processing the data using the standard methods and applying the MC in the image space, demonstrating the quantitative accuracy of the novel MC algorithm. In human volunteer studies, motion estimates were obtained from echo planar imaging and cloverleaf navigator sequences every 3 seconds and 20 ms, respectively. Substantially improved PET images with excellent delineation of specific brain structures were obtained after applying the MC using these MR-based estimates. Conclusion A novel MR-based MC algorithm was developed for the integrated MR-PET scanner. High temporal resolution MR-derived motion estimates (obtained while simultaneously acquiring anatomical or functional MR data) can be used for PET MC. An MR-based MC has the potential to improve PET as a quantitative method, increasing its reliability and reproducibility which could benefit a large number of neurological applications. PMID:21189415
Calf restoration with asymmetric fat injection in polio sequelae.
Yazar, Memet; Kurt Yazar, Sevgi; Kozanoğlu, Erol
2016-09-01
Many things cause leg asymmetry and sequelae seen after poliomyelitis infections are still a cause of leg deformities. In this study, lipofilling and liposuction combinations are performed on patients with poliomyelitis sequelae. Volume deficiency is not the only leg problem with polio sequelae, leg length is also a problem. For this reason, the length deficiency must be addressed in order to achieve the desired symmetry. The aim of this study is correcting limb asymmetry by a method addressing both limb length deficiency by heel raise and volume deficiency by injection of fat based on corrected limb length. From 2011 through 2013, 10 female patients who had unilateral leg atrophy as a result of paediatric polio infections were included in our study. All of the patients were treated with liposuction and lipofilling combinations. During planning, a ridge was placed under the affected leg in order to equalize the lengths of both legs. The fat injection sites on the affected leg were marked to mimic the unaffected leg. All the patients stated that they were satisfied with the results. Transient hypoesthesia was seen in only one patient, but this was spontaneously resolved six months later. The study results indicate that the asymmetric fat injection procedure can be a good technique to use with patients who have polio sequelae, both with short legs and volume deformities. 4. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Intrauterine growth restriction affects the preterm infant's hippocampus.
Lodygensky, Gregory A; Seghier, Mohammed L; Warfield, Simon K; Tolsa, Cristina Borradori; Sizonenko, Stephane; Lazeyras, François; Hüppi, Petra S
2008-04-01
The hippocampus is known to be vulnerable to hypoxia, stress, and undernutrition, all likely to be present in fetal intrauterine growth restriction (IUGR). The effect of IUGR in preterm infants on the hippocampus was studied using 3D magnetic resonance imaging at term-equivalent age Thirteen preterm infants born with IUGR after placental insufficiency were compared with 13 infants with normal intrauterine growth age matched for gestational age. The hippocampal structural differences were defined using voxel-based morphometry and manual segmentation. The specific neurobehavioral function was evaluated by the Assessment of Preterm Infants' Behavior at term and at 24 mo of corrected age by a Bayley Scales of Infant and Toddler Development. Voxel-based morphometry detected significant gray matter volume differences in the hippocampus between the two groups. This finding was confirmed by manual segmentation of the hippocampus with a reduction of hippocampal volume after IUGR. The hippocampal volume reduction was further associated with functional behavioral differences at term-equivalent age in all six subdomains of the Assessment of Preterm Infants' Behavior but not at 24 mo of corrected age. We conclude that hippocampal development in IUGR is altered and might result from a combination of maternal corticosteroid hormone exposure, hypoxemia, and micronutrient deficiency.
Palmer, David S; Frolov, Andrey I; Ratkova, Ekaterina L; Fedorov, Maxim V
2010-12-15
We report a simple universal method to systematically improve the accuracy of hydration free energies calculated using an integral equation theory of molecular liquids, the 3D reference interaction site model. A strong linear correlation is observed between the difference of the experimental and (uncorrected) calculated hydration free energies and the calculated partial molar volume for a data set of 185 neutral organic molecules from different chemical classes. By using the partial molar volume as a linear empirical correction to the calculated hydration free energy, we obtain predictions of hydration free energies in excellent agreement with experiment (R = 0.94, σ = 0.99 kcal mol (- 1) for a test set of 120 organic molecules).
Berman, Steven M.; London, Edythe D.; Morgan, Melinda; Rapkin, Andrea J.
2012-01-01
OBJECTIVE Premenstrual dysphoric disorder (PMDD) is characterized by severe, negative mood symptoms during the luteal phase of each menstrual cycle. We recently reported that women with PMDD show a greater increase in relative glucose metabolism in the posterior cerebellum from the follicular to the luteal phase, as compared with healthy women, and that the phase-related increase is proportional to PMDD symptom severity. We extended this work with a study of brain structure in PMDD. METHODS High-resolution magnetic resonance imaging (MRI) scans were obtained from 12 women with PMDD and 13 healthy control subjects (whole-brain volume-corrected p<.05). Voxel-based morphometry was used to assess group differences in cerebral grey-matter volume (GMV), using a statistical criterion of p<.05, correcting for multiple comparisons in the whole-brain volume. RESULTS PMDD subjects had greater GMV than controls in the posterior cerebellum but not in any other brain area. Age was negatively correlated with GMV within this region in healthy women, but not in women with PMDD. The group difference in GMV was significant for women over age 30 (p=.0002) but not younger participants (p>.1). CONCLUSIONS PMDD appears to be associated with reduced age-related loss in posterior cerebellar GMV. Although the mechanism underlying this finding is unclear, cumulative effects of symptom-related cerebellar activity may be involved. PMID:22868063
Automated 3D Ultrasound Image Segmentation to Aid Breast Cancer Image Interpretation
Gu, Peng; Lee, Won-Mean; Roubidoux, Marilyn A.; Yuan, Jie; Wang, Xueding; Carson, Paul L.
2015-01-01
Segmentation of an ultrasound image into functional tissues is of great importance to clinical diagnosis of breast cancer. However, many studies are found to segment only the mass of interest and not all major tissues. Differences and inconsistencies in ultrasound interpretation call for an automated segmentation method to make results operator-independent. Furthermore, manual segmentation of entire three-dimensional (3D) ultrasound volumes is time-consuming, resource-intensive, and clinically impractical. Here, we propose an automated algorithm to segment 3D ultrasound volumes into three major tissue types: cyst/mass, fatty tissue, and fibro-glandular tissue. To test its efficacy and consistency, the proposed automated method was employed on a database of 21 cases of whole breast ultrasound. Experimental results show that our proposed method not only distinguishes fat and non-fat tissues correctly, but performs well in classifying cyst/mass. Comparison of density assessment between the automated method and manual segmentation demonstrates good consistency with an accuracy of 85.7%. Quantitative comparison of corresponding tissue volumes, which uses overlap ratio, gives an average similarity of 74.54%, consistent with values seen in MRI brain segmentations. Thus, our proposed method exhibits great potential as an automated approach to segment 3D whole breast ultrasound volumes into functionally distinct tissues that may help to correct ultrasound speed of sound aberrations and assist in density based prognosis of breast cancer. PMID:26547117
Automated 3D ultrasound image segmentation for assistant diagnosis of breast cancer
NASA Astrophysics Data System (ADS)
Wang, Yuxin; Gu, Peng; Lee, Won-Mean; Roubidoux, Marilyn A.; Du, Sidan; Yuan, Jie; Wang, Xueding; Carson, Paul L.
2016-04-01
Segmentation of an ultrasound image into functional tissues is of great importance to clinical diagnosis of breast cancer. However, many studies are found to segment only the mass of interest and not all major tissues. Differences and inconsistencies in ultrasound interpretation call for an automated segmentation method to make results operator-independent. Furthermore, manual segmentation of entire three-dimensional (3D) ultrasound volumes is time-consuming, resource-intensive, and clinically impractical. Here, we propose an automated algorithm to segment 3D ultrasound volumes into three major tissue types: cyst/mass, fatty tissue, and fibro-glandular tissue. To test its efficacy and consistency, the proposed automated method was employed on a database of 21 cases of whole breast ultrasound. Experimental results show that our proposed method not only distinguishes fat and non-fat tissues correctly, but performs well in classifying cyst/mass. Comparison of density assessment between the automated method and manual segmentation demonstrates good consistency with an accuracy of 85.7%. Quantitative comparison of corresponding tissue volumes, which uses overlap ratio, gives an average similarity of 74.54%, consistent with values seen in MRI brain segmentations. Thus, our proposed method exhibits great potential as an automated approach to segment 3D whole breast ultrasound volumes into functionally distinct tissues that may help to correct ultrasound speed of sound aberrations and assist in density based prognosis of breast cancer.
DETERMINATION OF THE SPEED OF SOUND ALONG THE HUGONIOT IN A SHOCKED MATERIAL
2017-04-25
correctly predict higher speeds of sound for the higher energy shocked states. The approximations of higher shock pressures diverge progressively...List 11 FIGURES 1 Copper Hugoniot pressure-specific volume plane 4 2 Copper Hugoniot energy -specific volume plane 4 3 Comparison between rate of...volume and energy are being used. = (, ) Then by the chain rule: = | + | Dividing by dv
Krishna P. Poudel; Temesgen Hailemariam
2016-01-01
Using data from destructively sampled Douglas-fir and lodgepole pine trees, we evaluated the performance of regional volume and component biomass equations in terms of bias and RMSE. The volume and component biomass equations were calibrated using three different adjustment methods that used: (a) a correction factor based on ordinary least square regression through...
Peripheral telomere length and hippocampal volume in adolescents with major depressive disorder.
Henje Blom, E; Han, L K M; Connolly, C G; Ho, T C; Lin, J; LeWinn, K Z; Simmons, A N; Sacchet, M D; Mobayed, N; Luna, M E; Paulus, M; Epel, E S; Blackburn, E H; Wolkowitz, O M; Yang, T T
2015-11-10
Several studies have reported that adults with major depressive disorder have shorter telomere length and reduced hippocampal volumes. Moreover, studies of adult populations without major depressive disorder suggest a relationship between peripheral telomere length and hippocampal volume. However, the relationship of these findings in adolescents with major depressive disorder has yet to be explored. We examined whether adolescent major depressive disorder is associated with altered peripheral telomere length and hippocampal volume, and whether these measures relate to one another. In 54 unmedicated adolescents (13-18 years) with major depressive disorder and 63 well-matched healthy controls, telomere length was assessed from saliva using quantitative polymerase chain reaction methods, and bilateral hippocampal volumes were measured with magnetic resonance imaging. After adjusting for age and sex (and total brain volume in the hippocampal analysis), adolescents with major depressive disorder exhibited significantly shorter telomere length and significantly smaller right, but not left hippocampal volume. When corrected for age, sex, diagnostic group and total brain volume, telomere length was not significantly associated with left or right hippocampal volume, suggesting that these cellular and neural processes may be mechanistically distinct during adolescence. Our findings suggest that shortening of telomere length and reduction of hippocampal volume are already present in early-onset major depressive disorder and thus unlikely to be only a result of accumulated years of exposure to major depressive disorder.
Chang, Guoping; Chang, Tingting; Pan, Tinsu; Clark, John W; Mawlawi, Osama R
2010-12-01
Respiratory motion artifacts and partial volume effects (PVEs) are two degrading factors that affect the accuracy of image quantification in PET/CT imaging. In this article, the authors propose a joint motion and PVE correction approach (JMPC) to improve PET quantification by simultaneously correcting for respiratory motion artifacts and PVE in patients with lung/thoracic cancer. The objective of this article is to describe this approach and evaluate its performance using phantom and patient studies. The proposed joint correction approach incorporates a model of motion blurring, PVE, and object size/shape. A motion blurring kernel (MBK) is then estimated from the deconvolution of the joint model, while the activity concentration (AC) of the tumor is estimated from the normalization of the derived MBK. To evaluate the performance of this approach, two phantom studies and eight patient studies were performed. In the phantom studies, two motion waveforms-a linear sinusoidal and a circular motion-were used to control the motion of a sphere, while in the patient studies, all participants were instructed to breathe regularly. For the phantom studies, the resultant MBK was compared to the true MBK by measuring a correlation coefficient between the two kernels. The measured sphere AC derived from the proposed method was compared to the true AC as well as the ACs in images exhibiting PVE only and images exhibiting both PVE and motion blurring. For the patient studies, the resultant MBK was compared to the motion extent derived from a 4D-CT study, while the measured tumor AC was compared to the AC in images exhibiting both PVE and motion blurring. For the phantom studies, the estimated MBK approximated the true MBK with an average correlation coefficient of 0.91. The tumor ACs following the joint correction technique were similar to the true AC with an average difference of 2%. Furthermore, the tumor ACs on the PVE only images and images with both motion blur and PVE effects were, on average, 75% and 47.5% (10%) of the true AC, respectively, for the linear (circular) motion phantom study. For the patient studies, the maximum and mean AC/SUV on the PET images following the joint correction are, on average, increased by 125.9% and 371.6%, respectively, when compared to the PET images with both PVE and motion. The motion extents measured from the derived MBK and 4D-CT exhibited an average difference of 1.9 mm. The proposed joint correction approach can improve the accuracy of PET quantification by simultaneously compensating for the respiratory motion artifacts and PVE in lung/thoracic PET/CT imaging.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daily, Michael D.; Olsen, Brett N.; Schlesinger, Paul H.
In mammalian cells cholesterol is essential for membrane function, but in excess can be cytototoxic. The cellular response to acute cholesterol loading involves biophysical-based mechanisms that regulate cholesterol levels, through modulation of the “activity” or accessibility of cholesterol to extra-membrane acceptors. Experiments and united atom (UA) simulations show that at high concentrations of cholesterol, lipid bilayers thin significantly and cholesterol availability to external acceptors increases substantially. Such cholesterol activation is critical to its trafficking within cells. Here we aim to reduce the computational cost to enable simulation of large and complex systems involved in cholesterol regulation, such as those includingmore » oxysterols and cholesterol-sensing proteins. To accomplish this, we have modified the published MARTINI coarse-grained force field to improve its predictions of cholesterol-induced changes in both macroscopic and microscopic properties of membranes. Most notably, MARTINI fails to capture both the (macroscopic) area condensation and membrane thickening seen at less than 30% cholesterol and the thinning seen above 40% cholesterol. The thinning at high concentration is critical to cholesterol activation. Microscopic properties of interest include cholesterol-cholesterol radial distribution functions (RDFs), tilt angle, and accessible surface area. First, we develop an “angle-corrected” model wherein we modify the coarse-grained bond angle potentials based on atomistic simulations. This modification significantly improves prediction of macroscopic properties, most notably the thickening/thinning behavior, and also slightly improves microscopic property prediction relative to MARTINI. Second, we add to the angle correction a “volume correction” by also adjusting phospholipid bond lengths to achieve a more accurate volume per molecule. The angle + volume correction substantially further improves the quantitative agreement of the macroscopic properties (area per molecule and thickness) with united atom simulations. However, this improvement also reduces the accuracy of microscopic predictions like radial distribution functions and cholesterol tilt below that of either MARTINI or the angle-corrected model. Thus, while both of our forcefield corrections improve MARTINI, the combined angle and volume correction should be used for problems involving sterol effects on the overall structure of the membrane, while our angle-corrected model should be used in cases where the properties of individual lipid and sterol models are critically important.« less
Dias, Jorge; Malheiro, Jorge; Almeida, Manuela; Dias, Leonídio; Silva-Ramos, Miguel; Martins, La Salete; Xambre, Luís; Castro-Henriques, António
2015-05-01
Donated kidney volume influences post-transplant outcomes and graft survival. We evaluated the relationship between living-donor kidney volume and recipient graft function at 12 months post-transplantation, exploring a volume threshold for a suboptimal graft function, and compared two different formulas of volume estimation. A retrospective analysis of 82 pairs of living-donor kidney transplants was conducted. Donor renal volumes were estimated from computerized tomography scans using the ellipsoid formula and the voxel counting technique. Linear and restricted cubic regression spline was used to analyze the association of volume with graft function. Additionally, we determined the correlation between the two volume estimation formulas and established a correction factor for the ellipsoid formula. Renal volume (adjusted to recipient BSA) had the strongest independent effect (B = 1.65 per 10 ml/m(2) increase, p value <0.001) on graft function at 12 months. The eGFR at 12 months was 52.5, 63.6 and 67.6 ml/min/1.73 m(2) for the low, medium and high volume ratio terciles, respectively (p value <0.001). The odds of a GFR <50 ml/min became significantly reduced with volumes above 145 cc/1.73 m(2). A strong positive correlation between the two formulas was identified (R(2) = 0.705), but the optimal correction factor for our cohort was 0.566. In a Caucasian population, higher donor kidney volumes estimated from preoperative CT scans are associated with higher recipient eGFRs at 12 months after live-donor transplantation. Using this criterion, transplant teams can potentially improve selection of living donors if multiple donors are available. However, the need for precise estimation of donor kidney volumes should not be overlooked.
Cerebral gray matter volume in patients with chronic migraine: correlations with clinical features.
Coppola, Gianluca; Petolicchio, Barbara; Di Renzo, Antonio; Tinelli, Emanuele; Di Lorenzo, Cherubino; Parisi, Vincenzo; Serrao, Mariano; Calistri, Valentina; Tardioli, Stefano; Cartocci, Gaia; Ambrosini, Anna; Caramia, Francesca; Di Piero, Vittorio; Pierelli, Francesco
2017-12-08
To date, few MRI studies have been performed in patients affected by chronic migraine (CM), especially in those without medication overuse. Here, we performed magnetic resonance imaging (MRI) voxel-based morphometry (VBM) analyses to investigate the gray matter (GM) volume of the whole brain in patients affected by CM. Our aim was to investigate whether fluctuations in the GM volumes were related to the clinical features of CM. Twenty untreated patients with CM without a past medical history of medication overuse underwent 3-Tesla MRI scans and were compared to a group of 20 healthy controls (HCs). We used SPM12 and the CAT12 toolbox to process the MRI data and to perform VBM analyses of the structural T1-weighted MRI scans. The GM volume of patients was compared to that of HCs with various corrected and uncorrected thresholds. To check for possible correlations, patients' clinical features and GM maps were regressed. Initially, we did not find significant differences in the GM volume between patients with CM and HCs (p < 0.05 corrected for multiple comparisons). However, using more-liberal uncorrected statistical thresholds, we noted that compared to HCs, patients with CM exhibited clusters of regions with lower GM volumes including the cerebellum, left middle temporal gyrus, left temporal pole/amygdala/hippocampus/pallidum/orbitofrontal cortex, and left occipital areas (Brodmann areas 17/18). The GM volume of the cerebellar hemispheres was negatively correlated with the disease duration and positively correlated with the number of tablets taken per month. No gross morphometric changes were observed in patients with CM when compared with HCs. However, using more-liberal uncorrected statistical thresholds, we observed that CM is associated with subtle GM volume changes in several brain areas known to be involved in nociception/antinociception, multisensory integration, and analgesic dependence. We speculate that these slight morphometric impairments could lead, at least in a subgroup of patients, to the development and continuation of maladaptive acute medication usage.
SU-E-I-79: Source Geometry Dependence of Gamma Well-Counter Measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, M; Belanger, A; Kijewski, M
Purpose: To determine the effect of liquid sample volume and geometry on counting efficiency in a gamma well-counter, and to assess the relative contributions of sample geometry and self-attenuation. Gamma wellcounters are standard equipment in clinical and preclinical studies, for measuring patient blood radioactivity and quantifying animal tissue uptake for tracer development and other purposes. Accurate measurements are crucial. Methods: Count rates were measured for aqueous solutions of 99m- Tc at four liquid volume values in a 1-cm-diam tube and at six volume values in a 2.2-cm-diam vial. Total activity was constant for all volumes, and data were corrected formore » decay. Count rates from a point source in air, supported by a filter paper, were measured at seven heights between 1.3 and 5.7 cm from the bottom of a tube. Results: Sample volume effects were larger for the tube than for the vial. For the tube, count efficiency relative to a 1-cc volume ranged from 1.05 at 0.05 cc to 0.84 at 3 cc. For the vial, relative count efficiency ranged from 1.02 at 0.05 cc to 0.87 at 15 cc. For the point source, count efficiency relative to 1.3 cm from the tube bottom ranged from 0.98 at 1.8 cm to 0.34 at 5.7 cm. The relative efficiency of a 3-cc liquid sample in a tube compared to a 1-cc sample is 0.84; the average relative efficiency for the solid sample in air between heights in the tube corresponding to the surfaces of those volumes (1.3 and 4.8 cm) is 0.81, implying that the major contribution to efficiency loss is geometry, rather than attenuation. Conclusion: Volume-dependent correction factors should be used for accurate quantitation radioactive of liquid samples. Solid samples should be positioned at the bottom of the tube for maximum count efficiency.« less
Association of IQ Changes and Progressive Brain Changes in Patients With Schizophrenia.
Kubota, Manabu; van Haren, Neeltje E M; Haijma, Sander V; Schnack, Hugo G; Cahn, Wiepke; Hulshoff Pol, Hilleke E; Kahn, René S
2015-08-01
Although schizophrenia is characterized by impairments in intelligence and the loss of brain volume, the relationship between changes in IQ and brain measures is not clear. To investigate the association between IQ and brain measures in patients with schizophrenia across time. Case-control longitudinal study at the Department of Psychiatry at the University Medical Center Utrecht, Utrecht, the Netherlands, comparing patients with schizophrenia and healthy control participants between September 22, 2004, and April 17, 2008. Magnetic resonance imaging of the brain and IQ scores were obtained at baseline and the 3-year follow-up. Participants included 84 patients with schizophrenia (mean illness duration, 4.35 years) and 116 age-matched healthy control participants. Associations between changes in IQ and the total brain, cerebral gray matter, cerebral white matter, lateral ventricular, third ventricles, cortical, and subcortical volumes; cortical thickness; and cortical surface area. Cerebral gray matter volume (P = .006) and cortical volume (P = .03) and thickness (P = .02) decreased more in patients with schizophrenia across time compared with control participants. Patients showed additional loss in cortical volume and thickness of the right supramarginal, posterior superior temporal, left supramarginal, left postcentral, and occipital regions (P values were between <.001 and .03 after clusterwise correction). Although IQ increased similarly in patients with schizophrenia and control participants, changes in IQ were negatively correlated with changes in lateral ventricular volume (P = .05) and positively correlated with changes in cortical volume (P = .007) and thickness (P = .004) only in patients with schizophrenia. Positive correlations between changes in IQ and cortical volume and thickness were found globally and in widespread regions across frontal, temporal, and parietal cortices (P values were between <.001 and .03 after clusterwise correction). These findings were independent of symptom severity at follow-up, cannabis use, and the use of cumulative antipsychotic medications during the 3 years of follow-up. Progressive brain tissue loss in schizophrenia is related to relative cognitive decline during the early course of illness.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Algan, Ozer, E-mail: oalgan@ouhsc.edu; Jamgade, Ambarish; Ali, Imad
2012-01-01
The purpose of this study was to evaluate the impact of daily setup error and interfraction organ motion on the overall dosimetric radiation treatment plans. Twelve patients undergoing definitive intensity-modulated radiation therapy (IMRT) treatments for prostate cancer were evaluated in this institutional review board-approved study. Each patient had fiducial markers placed into the prostate gland before treatment planning computed tomography scan. IMRT plans were generated using the Eclipse treatment planning system. Each patient was treated to a dose of 8100 cGy given in 45 fractions. In this study, we retrospectively created a plan for each treatment day that had amore » shift available. To calculate the dose, the patient would have received under this plan, we mathematically 'negated' the shift by moving the isocenter in the exact opposite direction of the shift. The individualized daily plans were combined to generate an overall plan sum. The dose distributions from these plans were compared with the treatment plans that were used to treat the patients. Three-hundred ninety daily shifts were negated and their corresponding plans evaluated. The mean isocenter shift based on the location of the fiducial markers was 3.3 {+-} 6.5 mm to the right, 1.6 {+-} 5.1 mm posteriorly, and 1.0 {+-} 5.0 mm along the caudal direction. The mean D95 doses for the prostate gland when setup error was corrected and uncorrected were 8228 and 7844 cGy (p < 0.002), respectively, and for the planning target volume (PTV8100) was 8089 and 7303 cGy (p < 0.001), respectively. The mean V95 values when patient setup was corrected and uncorrected were 99.9% and 87.3%, respectively, for the PTV8100 volume (p < 0.0001). At an individual patient level, the difference in the D95 value for the prostate volume could be >1200 cGy and for the PTV8100 could approach almost 2000 cGy when comparing corrected against uncorrected plans. There was no statistically significant difference in the D35 parameter for the surrounding normal tissue except for the dose received by the penile bulb and the right hip. Our dosimetric evaluation suggests significant underdosing with inaccurate target localization and emphasizes the importance of accurate patient setup and target localization. Further studies are needed to evaluate the impact of intrafraction organ motion, rotation, and deformation on doses delivered to target volumes.« less
Tan, Y M; Flynn, M R
2000-10-01
The transfer efficiency of a spray-painting gun is defined as the amount of coating applied to the workpiece divided by the amount sprayed. Characterizing this transfer process allows for accurate estimation of the overspray generation rate, which is important for determining a spray painter's exposure to airborne contaminants. This study presents an experimental evaluation of a mathematical model for predicting the transfer efficiency of a high volume-low pressure spray gun. The effects of gun-to-surface distance and nozzle pressure on the agreement between the transfer efficiency measurement and prediction were examined. Wind tunnel studies and non-volatile vacuum pump oil in place of commercial paint were used to determine transfer efficiency at nine gun-to-surface distances and four nozzle pressure levels. The mathematical model successfully predicts transfer efficiency within the uncertainty limits. The least squares regression between measured and predicted transfer efficiency has a slope of 0.83 and an intercept of 0.12 (R2 = 0.98). Two correction factors were determined to improve the mathematical model. At higher nozzle pressure settings, 6.5 psig and 5.5 psig, the correction factor is a function of both gun-to-surface distance and nozzle pressure level. At lower nozzle pressures, 4 psig and 2.75 psig, gun-to-surface distance slightly influences the correction factor, while nozzle pressure has no discernible effect.
The influence of CT based attenuation correction on PET/CT registration: an evaluation study
NASA Astrophysics Data System (ADS)
Yaniv, Ziv; Wong, Kenneth H.; Banovac, Filip; Levy, Elliot; Cleary, Kevin
2007-03-01
We are currently developing a PET/CT based navigation system for guidance of biopsies and radiofrequency ablation (RFA) of early stage hepatic tumors. For these procedures, combined PET/CT data can potentially improve current interventions. The diagnostic efficacy of biopsies can potentially be improved by accurately targeting the region within the tumor that exhibits the highest metabolic activity. For RFA procedures the system can potentially enable treatment of early stage tumors, targeting tumors before structural abnormalities are clearly visible on CT. In both cases target definition is based on the metabolic data (PET), and navigation is based on the spatial data (CT), making the system highly dependent upon accurate spatial alignment between these data sets. In our institute all clinical data sets include three image volumes: one CT, and two PET volumes, with and without CT-based attenuation correction. This paper studies the effect of the CT-based attenuation correction on the registration process. From comparing the pairs of registrations from five data sets we observe that the point motion magnitude difference between registrations is on the same scale as the point motion magnitude in each one of the registrations, and that visual inspection cannot identify this discrepancy. We conclude that using non-rigid registration to align the PET and CT data sets is too variable, and most likely does not provide sufficient accuracy for interventional procedures.
Wu, S; He, Z; Guo, J; Li, F; Lin, Q; Guan, X
2014-01-01
To assess the heart and lung dosimetry results associated with accelerated partial breast irradiation intensity-modulated radiotherapy (APBI-IMRT) and whole breast field-in-field intensity-modulated radiotherapy (WBI-FIF-IMRT). A total of 29 patients with early-stage breast cancer after lumpectomy were included in this study. APBI-IMRT and WBI-FIF-IMRT plans were generated for each patient. The dosimetric parameters of ipsilateral lung and heart in both plans were then compared with and without radiobiological correction. With and without radiobiological correction, the volume of ipsilateral lung showed a substantially lower radiation exposure in APBI-IMRT with moderate to high doses (P < 0.05) but non-significant increases in volume of ipsilateral lung in 2.5 Gy than WBI-FIF-IMRT (P > 0.905).There was no significant difference in volume of ipsilateral lung receiving 1, 2.5, and 5 Gy between APBI-IMRT and WBI (P > 0.05) in patients with medial tumor location, although APBI-IMRT exposed more lung to 2.5 and 5 Gy. APBI-IMRT significantly decreases the volume of heart receiving low to high doses in left-sided breast cancer (P < 0.05). APBI-IMRT can significantly spare the volume of heart and ipsilateral lung receiving moderate and high dose. Non-significant increases in volume of the ipsilateral lung exposed to low doses of radiation were observed for APBI-IMRT in comparison to WBI-FIF-IMRT, particularly in patients with medial tumor location. With the increasing interest in APBI-IMRT, our data may help clinicians individualize patient treatment decisions.
Event-by-Event Continuous Respiratory Motion Correction for Dynamic PET Imaging.
Yu, Yunhan; Chan, Chung; Ma, Tianyu; Liu, Yaqiang; Gallezot, Jean-Dominique; Naganawa, Mika; Kelada, Olivia J; Germino, Mary; Sinusas, Albert J; Carson, Richard E; Liu, Chi
2016-07-01
Existing respiratory motion-correction methods are applied only to static PET imaging. We have previously developed an event-by-event respiratory motion-correction method with correlations between internal organ motion and external respiratory signals (INTEX). This method is uniquely appropriate for dynamic imaging because it corrects motion for each time point. In this study, we applied INTEX to human dynamic PET studies with various tracers and investigated the impact on kinetic parameter estimation. The use of 3 tracers-a myocardial perfusion tracer, (82)Rb (n = 7); a pancreatic β-cell tracer, (18)F-FP(+)DTBZ (n = 4); and a tumor hypoxia tracer, (18)F-fluoromisonidazole ((18)F-FMISO) (n = 1)-was investigated in a study of 12 human subjects. Both rest and stress studies were performed for (82)Rb. The Anzai belt system was used to record respiratory motion. Three-dimensional internal organ motion in high temporal resolution was calculated by INTEX to guide event-by-event respiratory motion correction of target organs in each dynamic frame. Time-activity curves of regions of interest drawn based on end-expiration PET images were obtained. For (82)Rb studies, K1 was obtained with a 1-tissue model using a left-ventricle input function. Rest-stress myocardial blood flow (MBF) and coronary flow reserve (CFR) were determined. For (18)F-FP(+)DTBZ studies, the total volume of distribution was estimated with arterial input functions using the multilinear analysis 1 method. For the (18)F-FMISO study, the net uptake rate Ki was obtained with a 2-tissue irreversible model using a left-ventricle input function. All parameters were compared with the values derived without motion correction. With INTEX, K1 and MBF increased by 10% ± 12% and 15% ± 19%, respectively, for (82)Rb stress studies. CFR increased by 19% ± 21%. For studies with motion amplitudes greater than 8 mm (n = 3), K1, MBF, and CFR increased by 20% ± 12%, 30% ± 20%, and 34% ± 23%, respectively. For (82)Rb rest studies, INTEX had minimal effect on parameter estimation. The total volume of distribution of (18)F-FP(+)DTBZ and Ki of (18)F-FMISO increased by 17% ± 6% and 20%, respectively. Respiratory motion can have a substantial impact on dynamic PET in the thorax and abdomen. The INTEX method using continuous external motion data substantially changed parameters in kinetic modeling. More accurate estimation is expected with INTEX. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Local respiratory motion correction for PET/CT imaging: Application to lung cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lamare, F., E-mail: frederic.lamare@chu-bordeaux.fr; Fernandez, P.; Fayad, H.
Purpose: Despite multiple methodologies already proposed to correct respiratory motion in the whole PET imaging field of view (FOV), such approaches have not found wide acceptance in clinical routine. An alternative can be the local respiratory motion correction (LRMC) of data corresponding to a given volume of interest (VOI: organ or tumor). Advantages of LRMC include the use of a simple motion model, faster execution times, and organ specific motion correction. The purpose of this study was to evaluate the performance of LMRC using various motion models for oncology (lung lesion) applications. Methods: Both simulated (NURBS based 4D cardiac-torso phantom)more » and clinical studies (six patients) were used in the evaluation of the proposed LRMC approach. PET data were acquired in list-mode and synchronized with respiration. The implemented approach consists first in defining a VOI on the reconstructed motion average image. Gated PET images of the VOI are subsequently reconstructed using only lines of response passing through the selected VOI and are used in combination with a center of gravity or an affine/elastic registration algorithm to derive the transformation maps corresponding to the respiration effects. Those are finally integrated in the reconstruction process to produce a motion free image over the lesion regions. Results: Although the center of gravity or affine algorithm achieved similar performance for individual lesion motion correction, the elastic model, applied either locally or to the whole FOV, led to an overall superior performance. The spatial tumor location was altered by 89% and 81% for the elastic model applied locally or to the whole FOV, respectively (compared to 44% and 39% for the center of gravity and affine models, respectively). This resulted in similar associated overall tumor volume changes of 84% and 80%, respectively (compared to 75% and 71% for the center of gravity and affine models, respectively). The application of the nonrigid deformation model in LRMC led to over an order of magnitude gain in computational efficiency of the correction relative to the application of the deformable model to the whole FOV. Conclusions: The results of this study support the use of LMRC as a flexible and efficient correction approach for respiratory motion effects for single lesions in the thoracic area.« less
Subcortical grey matter changes in untreated, early stage Parkinson's disease without dementia.
Lee, Hye Mi; Kwon, Kyum-Yil; Kim, Min-Jik; Jang, Ji-Wan; Suh, Sang-Il; Koh, Seong-Beom; Kim, Ji Hyun
2014-06-01
Previous MRI studies have investigated cortical or subcortical grey matter changes in patients with Parkinson's disease (PD), yielding inconsistent findings between the studies. We therefore sought to determine whether focal cortical or subcortical grey matter changes may be present from the early disease stage. We recruited 49 untreated, early stage PD patients without dementia and 53 control subjects. Voxel-based morphometry was used to evaluate cortical grey matter changes, and automated volumetry and shape analysis were used to assess volume changes and shape deformation of the subcortical grey matter structures, respectively. Voxel-based morphometry showed neither reductions nor increases in grey matter volume in patients compared to controls. Compared to controls, PD patients had significant reductions in adjusted volumes of putamen, nucleus accumbens, and hippocampus (corrected p < 0.05). Vertex-based shape analysis showed regionally contracted area on the posterolateral and ventromedial putamen bilaterally in PD patients (corrected p < 0.05). No correlations were found between cortical and subcortical grey matter and clinical variables representing disease duration and severity. Our results suggest that untreated, early stage PD without dementia is associated with volume reduction and shape deformation of subcortical grey matter, but not with cortical grey matter reduction. Our findings of structural changes in the posterolateral putamen and ventromedial putamen/nucleus accumbens could provide neuroanatomical basis for the involvement of motor and limbic striatum, further implicating motor and non-motor symptoms in PD, respectively. Early hippocampal involvement might be related to the risk for developing dementia in PD patients. Copyright © 2014 Elsevier Ltd. All rights reserved.
The relationship between renal volume and histology in obese and nonobese kidney donors.
Tatar, Erhan; Sen, Sait; Harman, Mustafa; Kircelli, Fatih; Gungor, Ozkan; Sarsik, Banu; Asci, Gulay; Hoscoskun, Cuneyt; Basci, Ali; Toz, Huseyin
2015-06-01
Obesity and related kidney diseases have become a global epidemic problem. However, the underlying pathogenesis of obesity-related renal diseases has not been clearly understood. In this study, we explored the link between renal volume (RV) determined by computed tomography (CT) and renal histology together with functional parameters in an obese population. Eighty-two kidney donors who underwent CT for the measurement of kidney volume and zero-hour renal biopsy for renal histology were included in this cross-sectional study. Protein creatinine clearance and eGFR were evaluated in 24-h urine specimens as indicators of renal function. Mean body mass index (BMI) was 28 ± 4.2 kg/m(2); 32.9% (n = 27) were obese. Mean RV was 196 ± 36 cm(3). RV was positively correlated with BMI, body surface area and creatinine clearance and negatively with HDL-cholesterol in the whole population. Renal function parameters of obese subjects were better, and their renal volumes were higher compared with the nonobese subjects. In obese subjects, corrected RV was positively correlated with glomerular filtration rate (r = 0.46, P = 0.01) and negatively with sclerotic glomeruli (r = -0.38, P = 0.04) and chronicity index (r = -0.43, P = 0.02). In adjusted ordinal logistic regression analysis, corrected RV was significantly associated with chronicity index (OR: 0.96; P = 0.01). In obese cases, decreased RV determined by CT is associated with worse renal histology. In this population, kidney imaging techniques may provide important clues about renal survival. © 2015 Stichting European Society for Clinical Investigation Journal Foundation.
Measurement of beta-plus emitters by gamma-ray spectrometry.
Lépy, Marie-Christine; Cassette, Philippe; Ferreux, Laurent
2010-01-01
The activity measurement of beta-plus emitters by gamma-ray spectrometry is studied. Experimental measurements are performed with (22)Na, (65)Zn and (64)Cu with sources included in a lead container. For these nuclides, the activity can be derived both from one photon emission peak and from the 511 keV annihilation peak, including annihilation in-flight correction and geometry correction computed by Monte Carlo simulation. The activity values obtained using the two types of peaks show satisfying agreement. The extension of the method to volume sources is discussed. Copyright 2009 Elsevier Ltd. All rights reserved.
Noise suppressed partial volume correction for cardiac SPECT/CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chan, Chung; Liu, Chi, E-mail: chi.liu@yale.edu
Purpose: Partial volume correction (PVC) methods typically improve quantification at the expense of increased image noise and reduced reproducibility. In this study, the authors developed a novel voxel-based PVC method that incorporates anatomical knowledge to improve quantification while suppressing noise for cardiac SPECT/CT imaging. Methods: In the proposed method, the SPECT images were first reconstructed using anatomical-based maximum a posteriori (AMAP) with Bowsher’s prior to penalize noise while preserving boundaries. A sequential voxel-by-voxel PVC approach (Yang’s method) was then applied on the AMAP reconstruction using a template response. This template response was obtained by forward projecting a template derived frommore » a contrast-enhanced CT image, and then reconstructed using AMAP to model the partial volume effects (PVEs) introduced by both the system resolution and the smoothing applied during reconstruction. To evaluate the proposed noise suppressed PVC (NS-PVC), the authors first simulated two types of cardiac SPECT studies: a {sup 99m}Tc-tetrofosmin myocardial perfusion scan and a {sup 99m}Tc-labeled red blood cell (RBC) scan on a dedicated cardiac multiple pinhole SPECT/CT at both high and low count levels. The authors then applied the proposed method on a canine equilibrium blood pool study following injection with {sup 99m}Tc-RBCs at different count levels by rebinning the list-mode data into shorter acquisitions. The proposed method was compared to MLEM reconstruction without PVC, two conventional PVC methods, including Yang’s method and multitarget correction (MTC) applied on the MLEM reconstruction, and AMAP reconstruction without PVC. Results: The results showed that the Yang’s method improved quantification, however, yielded increased noise and reduced reproducibility in the regions with higher activity. MTC corrected for PVE on high count data with amplified noise, although yielded the worst performance among all the methods tested on low-count data. AMAP effectively suppressed noise and reduced the spill-in effect in the low activity regions. However it was unable to reduce the spill-out effect in high activity regions. NS-PVC yielded superior performance in terms of both quantitative assessment and visual image quality while improving reproducibility. Conclusions: The results suggest that NS-PVC may be a promising PVC algorithm for application in low-dose protocols, and in gated and dynamic cardiac studies with low counts.« less
Grey matter volume loss is associated with specific clinical motor signs in Huntington's disease.
Coppen, Emma M; Jacobs, Milou; van den Berg-Huysmans, Annette A; van der Grond, Jeroen; Roos, Raymund A C
2018-01-01
Motor disturbances are clinical hallmarks of Huntington's disease (HD) and involve chorea, dystonia, hypokinesia and visuomotor dysfunction. Investigating the association between specific motor signs and different regional volumes is important to understand the heterogeneity of HD. To investigate the motor phenotype of HD and associations with subcortical and cortical grey matter volume loss. Structural T1-weighted MRI scans of 79 HD patients and 30 healthy controls were used to calculate volumes of seven subcortical structures including the nucleus accumbens, hippocampus, thalamus, caudate nucleus, putamen, pallidum and amygdala. Multiple linear regression analyses, corrected for age, gender, CAG, MRI scan protocol and normalized brain volume, were performed to assess the relationship between subcortical volumes and different motor subdomains (i.e. eye movements, chorea, dystonia, hypokinesia/rigidity and gait/balance). Voxel-based morphometry analysis was used to investigate the relationship between cortical volume changes and motor signs. Subcortical volume loss of the accumbens nucleus, caudate nucleus, putamen, and pallidum were associated with higher chorea scores. No other subcortical region was significantly associated with motor symptoms after correction for multiple comparisons. Voxel-based cortical grey matter volume reductions in occipital regions were related with an increase in eye movement scores. In HD, chorea is mainly associated with subcortical volume loss, while eye movements are more related to cortical volume loss. Both subcortical and cortical degeneration has an impact on motor impairment in HD. This implies that there is a widespread contribution of different brain regions resulting in the clinical motor presentation seen in HD patients. Copyright © 2017 Elsevier Ltd. All rights reserved.
Motion Artifact Reduction in Pediatric Diffusion Tensor Imaging Using Fast Prospective Correction
Alhamud, A.; Taylor, Paul A.; Laughton, Barbara; van der Kouwe, André J.W.; Meintjes, Ernesta M.
2014-01-01
Purpose To evaluate the patterns of head motion in scans of young children and to examine the influence of corrective techniques, both qualitatively and quantitatively. We investigate changes that both retrospective (with and without diffusion table reorientation) and prospective (implemented with a short navigator sequence) motion correction induce in the resulting diffusion tensor measures. Materials and Methods Eighteen pediatric subjects (aged 5–6 years) were scanned using 1) a twice-refocused, 2D diffusion pulse sequence, 2) a prospectively motion-corrected, navigated diffusion sequence with reacquisition of a maximum of five corrupted diffusion volumes, and 3) a T1-weighted structural image. Mean fractional anisotropy (FA) values in white and gray matter regions, as well as tractography in the brainstem and projection fibers, were evaluated to assess differences arising from retrospective (via FLIRT in FSL) and prospective motion correction. In addition to human scans, a stationary phantom was also used for further evaluation. Results In several white and gray matter regions retrospective correction led to significantly (P < 0.05) reduced FA means and altered distributions compared to the navigated sequence. Spurious tractographic changes in the retrospectively corrected data were also observed in subject data, as well as in phantom and simulated data. Conclusion Due to the heterogeneity of brain structures and the comparatively low resolution (~2 mm) of diffusion data using 2D single shot sequencing, retrospective motion correction is susceptible to distortion from partial voluming. These changes often negatively bias diffusion tensor imaging parameters. Prospective motion correction was shown to produce smaller changes. PMID:24935904
Motion artifact reduction in pediatric diffusion tensor imaging using fast prospective correction.
Alhamud, A; Taylor, Paul A; Laughton, Barbara; van der Kouwe, André J W; Meintjes, Ernesta M
2015-05-01
To evaluate the patterns of head motion in scans of young children and to examine the influence of corrective techniques, both qualitatively and quantitatively. We investigate changes that both retrospective (with and without diffusion table reorientation) and prospective (implemented with a short navigator sequence) motion correction induce in the resulting diffusion tensor measures. Eighteen pediatric subjects (aged 5-6 years) were scanned using 1) a twice-refocused, 2D diffusion pulse sequence, 2) a prospectively motion-corrected, navigated diffusion sequence with reacquisition of a maximum of five corrupted diffusion volumes, and 3) a T1 -weighted structural image. Mean fractional anisotropy (FA) values in white and gray matter regions, as well as tractography in the brainstem and projection fibers, were evaluated to assess differences arising from retrospective (via FLIRT in FSL) and prospective motion correction. In addition to human scans, a stationary phantom was also used for further evaluation. In several white and gray matter regions retrospective correction led to significantly (P < 0.05) reduced FA means and altered distributions compared to the navigated sequence. Spurious tractographic changes in the retrospectively corrected data were also observed in subject data, as well as in phantom and simulated data. Due to the heterogeneity of brain structures and the comparatively low resolution (∼2 mm) of diffusion data using 2D single shot sequencing, retrospective motion correction is susceptible to distortion from partial voluming. These changes often negatively bias diffusion tensor imaging parameters. Prospective motion correction was shown to produce smaller changes. © 2014 Wiley Periodicals, Inc.
Correction of Age-Related Midface Volume Loss With Low-Volume Hyaluronic Acid Filler.
Wilson, Monique Vanaman; Fabi, Sabrina Guillen; Greene, Ryan
2017-03-01
The pivotal approval trial for a smooth, highly cohesive, viscous, 20-mg/mL hyaluronic acid filler demonstrated sustained aesthetic improvement, with a mean injection volume of 6.65 mL. In daily practice, however, it is not often practical or necessary to use large injection volumes to achieve the desired cosmetic outcome. To assess the efficacy, longevity, and patient satisfaction associated with correction of age-related midface volume loss using the low volumes of hyaluronic acid filler more commonly used in day-to-day practice. A 2-center, retrospective cohort study examined medical records of 61 healthy patients who underwent treatment for facial volume loss with hyaluronic acid filler from November 1, 2013, through April 31, 2014. Follow-up visits were conducted at 1, 3, 6, and 12 months after the procedure. Data were pooled from a private facial plastic surgery practice in Weston, Florida, and a private cosmetic dermatology practice in San Diego, California. Patients were treated with hyaluronic acid filler according to the investigator's usual practices. The main outcome measure was patient-graded Global Aesthetic Improvement Scale scores at 1, 3, 6, and 12 months after treatment. Scores range from 1 to 5; 1 indicates very much improved and 5, worse. A total of 61 consecutive, healthy adult patients (mean [SD] age, 57.4 [12.8] years) with mild to severe facial volume loss were enrolled in the study. A total of 46 patients (75%) were white, 3 (5%) were black/African American, 9 (15%) were Hispanic/Latino, 1 (2%) was Asian/Pacific Islander, and 2 (3%) were other. Three patients (5%) were male, and 58 (95%) were female. Mean initial treatment volume was 1.6 mL. At follow-up, 29 patients (48%) elected to have a touch-up treatment; mean total touch-up volume was 1.4 mL. The patient-graded Global Aesthetic Improvement Scale scores at 1, 3, 6, and 12 months after treatment demonstrated that 73% (41 of 56) to 89% (24 of 27) of the study patients reported being very much or moderately improved. Most patients were rated by investigators on the Global Aesthetic Improvement Scale as very much or moderately improved at the 12-month follow-up. At 12 months after the procedure, 43 of 51 patients (84%) reported satisfaction with their outcome. At all time points, most patients would elect to undergo the procedure again (range, 17 [68%] to 61 [100%]). Adverse events were mild, and all resolved spontaneously within 14 days. At the 2-year follow-up, there were no reports of delayed adverse events. Midface volumization using the low volumes of hyaluronic acid filler more commonly used in daily clinical practice is effective and well tolerated. 3.
Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques.
Hofmann, Matthias; Pichler, Bernd; Schölkopf, Bernhard; Beyer, Thomas
2009-03-01
Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, or morphology templates generated from transmission images. We review and discuss these algorithms and point out challenges for using MR-AC in clinical routine. MR-AC is work-in-progress with potentially promising results from a template-based approach applicable to both brain and torso imaging. While efforts are ongoing in making clinically viable MR-AC fully automatic, further studies are required to realize the potential benefits of MR-based motion compensation and partial volume correction of the PET data.
Modeling of stress distributions on the microstructural level in Alloy 600
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kozaczek, K.J.; Petrovic, B.G.; Ruud, C.O.
1995-04-01
Stress distribution in a random polycrystalline material (Alloy 600) was studied using a topologically correct microstructural model. Distributions of von Mises and hydrostatic stresses at the grain vertices, which could be important in intergranular stress corrosion cracking, were analyzed as functions of microstructure, grain orientations and loading conditions. Grain size, shape, and orientation had a more pronounced effect on stress distribution than loading conditions. At grain vertices the stress concentration factor was higher for hydrostatic stress (1.7) than for von Mises stress (1.5). The stress/strain distribution in the volume (grain interiors) is a normal distribution and does not depend onmore » the location of the studied material volume i.e., surface vs/bulk. The analysis of stress distribution in the volume showed the von Mises stress concentration of 1.75 and stress concentration of 2.2 for the hydrostatic pressure. The observed stress concentration is high enough to cause localized plastic microdeformation, even when the polycrystalline aggregate is in the macroscopic elastic regime. Modeling of stresses and strains in polycrystalline materials can identify the microstructures (grain size distributions, texture) intrinsically susceptible to stress/strain concentrations and justify the correctness of applied stress state during the stress corrosion cracking tests. Also, it supplies the information necessary to formulate the local failure criteria and interpret of nondestructive stress measurements.« less
[Virtual endoscopy with a volumetric reconstruction technic: the technical aspects].
Pavone, P; Laghi, A; Panebianco, V; Catalano, C; Giura, R; Passariello, R
1998-06-01
We analyze the peculiar technical features of virtual endoscopy obtained with volume rendering. Our preliminary experience is based on virtual endoscopy images from volumetric data acquired with spiral CT (Siemens, Somatom Plus 4) using acquisition protocols standardized for different anatomic areas. Images are reformatted at the CT console, to obtain 1 mm thick contiguous slices, and transferred in DICOM format to an O2 workstation (Silicon Graphics, Mountain View CA, USA) with processor speed of 180 Mhz, 256 Mbyte RAM memory and 4.1 Gbyte hard disk. The software is Vitrea 1.0 (Vital Images, Fairfield, Iowa), running on a Unix platform. Image output is obtained through the Ethernet network to a Macintosh computer and a thermic printer (Kodak 8600 XLS). Diagnostic quality images were obtained in all the cases. Fly-through in the airways allowed correct evaluation of the main bronchi and of the origin of segmentary bronchi. In the vascular district, both carotid strictures and abdominal aortic aneurysms were depicted, with the same accuracy as with conventional reconstruction techniques. In the colon studies, polypoid lesions were correctly depicted in all the cases, with good correlation with endoscopic and double-contrast barium enema findings. In a case of lipoma of the ascending colon, virtual endoscopy allowed to study the colon both cranially and caudally to the lesion. The simultaneous evaluation of axial CT images permitted to characterize the lesion correctly on the basis of its density values. The peculiar feature of volume rendering is the use of the whole information inside the imaging volume to reconstruct three-dimensional images; no threshold values are used and no data are lost as opposite to conventional image reconstruction techniques. The different anatomic structures are visualized modifying the reciprocal opacities, showing the structures of no interest as translucent. The modulation of different opacities is obtained modifying the shape of the opacity curve, either using pre-set curves or in a completely independent way. Other technical features of volume rendering are the perspective evaluation of the objects, color and lighting. In conclusion, volume rendering is a promising technique to elaborate three-dimensional images, offering very realistic endoscopic views. At present, the main limitation is represented by the need of powerful and high-cost workstations.
Investigation of thermal and temporal responses of ionization chambers in radiation dosimetry.
AlMasri, Hussein; Funyu, Akira; Kakinohana, Yasumasa; Murayama, Sadayuki
2012-07-01
The ionization chamber is a primary dosimeter that is used in radiation dosimetry. Generally, the ion chamber response requires temperature/pressure correction according to the ideal gas law. However, this correction does not consider the thermal volume effect of chambers. The temporal and thermal volume effects of various chambers (CC01, CC13, NACP parallel-plate, PTW) with different wall and electrode materials have been studied in a water phantom. Measurements were done after heating the water with a suitable heating system, and chambers were submerged for a sufficient time to allow for temperature equilibrium. Temporal results show that all chambers equilibrate quickly in water. The equilibration time was between 3 and 5 min for all chambers. Thermal results show that all chambers expanded in response to heating except for the PTW, which contracted. This might be explained by the differences in the volumes of all chambers and also by the difference in wall material composition of PTW from the other chambers. It was found that the smallest chamber, CC01, showed the greatest expansion. The magnitude of the expansion was ~1, 0.8, and 0.9% for CC01, CC13, and parallel-plate chambers, respectively, in the temperature range of 295-320 K. The magnitude of the detected contraction was <0.3% for PTW in the same temperature range. For absolute dosimetry, it is necessary to make corrections for the ion chamber response, especially for small ion chambers like the CC01. Otherwise, room and water phantom temperatures should remain within a close range.
40 CFR 63.6620 - What performance tests and other procedures must I use?
Code of Federal Regulations, 2011 CFR
2011-07-01
... based on the ratio of oxygen volume to the ultimate CO2 volume produced by the fuel at zero percent... volume of CO2 produced to the gross calorific value of the fuel from Method 19, dsm3/J (dscf/106 Btu... equivalent percent carbon dioxide (CO2). If pollutant concentrations are to be corrected to 15 percent oxygen...
40 CFR 63.6620 - What performance tests and other procedures must I use?
Code of Federal Regulations, 2012 CFR
2012-07-01
... based on the ratio of oxygen volume to the ultimate CO2 volume produced by the fuel at zero percent... volume of CO2 produced to the gross calorific value of the fuel from Method 19, dsm3/J (dscf/106 Btu... equivalent percent carbon dioxide (CO2). If pollutant concentrations are to be corrected to 15 percent oxygen...
Effect of attenuation correction on image quality in emission tomography
NASA Astrophysics Data System (ADS)
Denisova, N. V.; Ondar, M. M.
2017-10-01
In this paper, mathematical modeling and computer simulations of myocardial perfusion SPECT imaging are performed. The main factors affecting the quality of reconstructed images in SPECT are anatomical structures, the diastolic volume of a myocardium and attenuation of gamma rays. The purpose of the present work is to study the effect of attenuation correction on image quality in emission tomography. The basic 2D model describing a Tc-99m distribution in a transaxial slice of the thoracic part of a patient body was designed. This model was used to construct four phantoms simulated various anatomical shapes: 2 male and 2 female patients with normal, obese and subtle physique were included in the study. Data acquisition model which includes the effect of non-uniform attenuation, collimator-detector response and Poisson statistics was developed. The projection data were calculated for 60 views in accordance with the standard myocardial perfusion SPECT imaging protocol. Reconstructions of images were performed using the OSEM algorithm which is widely used in modern SPECT systems. Two types of patient's examination procedures were simulated: SPECT without attenuation correction and SPECT/CT with attenuation correction. The obtained results indicate a significant effect of the attenuation correction on the SPECT images quality.
Yamamoto, Nana; Yamamoto, Takumi; Hayashi, Nobuko; Hayashi, Akitatsu; Iida, Takuya; Koshima, Isao
2016-06-01
Volumetry, measurement of extremity volume, is a commonly used method for upper extremity lymphedema (UEL) evaluation. However, comparison between different patients with different physiques is difficult with volumetry, because body-type difference greatly affects arm volume. Seventy arms of 35 participants who had no history of arm edema or breast cancer were evaluated. Arm volume was calculated using a summed truncated cone model, and UEL index was calculated using circumferences and body mass index (BMI). Examinees' BMI was classified into 3 groups, namely, low BMI (BMI, <20 kg/m), middle BMI (BMI, 20-25 kg/m), and high BMI (BMI, >25 kg/m). Arm volume and UEL index were compared with corresponding BMI groups. Mean (SD) arm volume was 1090.9 (205.5) mL, and UEL index 96.9 (5.6). There were significant differences in arm volume between BMI groups [low BMI vs middle BMI vs high BMI, 945.2 (107.4) vs 1045.2 (87.5) vs 1443.1 (244.4) mL, P < 0.001]. There was no significant difference in UEL index between BMI groups [low BMI vs middle BMI vs high BMI, 97.2 (4.2) vs 96.6 (4.6) vs 96.7 (9.9), P > 0.5]. Arm volume significantly increased with increase of BMI, whereas UEL index stayed constant regardless of BMI. Upper extremity lymphedema index would allow better body-type corrected arm volume evaluation compared with arm volumetry.
Diaphragm correction factors for the FAC-IR-300 free-air ionization chamber.
Mohammadi, Seyed Mostafa; Tavakoli-Anbaran, Hossein
2018-02-01
A free-air ionization chamber FAC-IR-300, designed by the Atomic Energy Organization of Iran, is used as the primary Iranian national standard for the photon air kerma. For accurate air kerma measurements, the contribution from the scattered photons to the total energy released in the collecting volume must be eliminated. One of the sources of scattered photons is the chamber's diaphragm. In this paper, the diaphragm scattering correction factor, k dia , and the diaphragm transmission correction factor, k tr , were introduced. These factors represent corrections to the measured charge (or current) for the photons scattered from the diaphragm surface and the photons penetrated through the diaphragm volume, respectively. The k dia and k tr values were estimated by Monte Carlo simulations. The simulations were performed for the mono-energetic photons in the energy range of 20 - 300keV. According to the simulation results, in this energy range, the k dia values vary between 0.9997 and 0.9948, and k tr values decrease from 1.0000 to 0.9965. The corrections grow in significance with increasing energy of the primary photons. Copyright © 2017 Elsevier Ltd. All rights reserved.
Zhao, Yan-feng; Lu, Ping; Zhou, Xiao-nan; Qu, Chang-feng
2010-03-01
To study the surgical management of enophthalmos after severe malar maxillary complex fracture. The X-ray and CT examination were performed before operation to diagnose the orbital fracture and intraorbital tissue displacement. The fractured orbital rim was repositioned intraoperatively, followed by implantation of shaped titanium mesh to rebuild the orbital floor. The Medpor was inserted above the titanium mesh to correct the enophthalmos. From Sept. 2007 to Jan. 2009, 6 cases of enophthalmos after severe malar-maxillary complex fracture were treated. The enophthalmos was corrected or improved obviously in all the patients. The enophthalmos after severe malar-maxillary complex fracture can be corrected or obviously improved. Shaped titanium mesh can be used to rebuild the orbital floor with the Medpor to reconstruct the intraorbital tissue volume.
Simultaneous multi-slice combined with PROPELLER.
Norbeck, Ola; Avventi, Enrico; Engström, Mathias; Rydén, Henric; Skare, Stefan
2018-08-01
Simultaneous multi-slice (SMS) imaging is an advantageous method for accelerating MRI scans, allowing reduced scan time, increased slice coverage, or high temporal resolution with limited image quality penalties. In this work we combine the advantages of SMS acceleration with the motion correction and artifact reduction capabilities of the PROPELLER technique. A PROPELLER sequence was developed with support for CAIPIRINHA and phase optimized multiband radio frequency pulses. To minimize the time spent on acquiring calibration data, both in-plane-generalized autocalibrating partial parallel acquisition (GRAPPA) and slice-GRAPPA weights for all PROPELLER blade angles were calibrated on a single fully sampled PROPELLER blade volume. Therefore, the proposed acquisition included a single fully sampled blade volume, with the remaining blades accelerated in both the phase and slice encoding directions without additional auto calibrating signal lines. Comparison to 3D RARE was performed as well as demonstration of 3D motion correction performance on the SMS PROPELLER data. We show that PROPELLER acquisitions can be efficiently accelerated with SMS using a short embedded calibration. The potential in combining these two techniques was demonstrated with a high quality 1.0 × 1.0 × 1.0 mm 3 resolution T 2 -weighted volume, free from banding artifacts, and capable of 3D retrospective motion correction, with higher effective resolution compared to 3D RARE. With the combination of SMS acceleration and PROPELLER imaging, thin-sliced reformattable T 2 -weighted image volumes with 3D retrospective motion correction capabilities can be rapidly acquired with low sensitivity to flow and head motion. Magn Reson Med 80:496-506, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Lobigs, Louisa M; Sottas, Pierre-Edouard; Bourdon, Pitre C; Nikolovski, Zoran; El-Gingo, Mohamed; Varamenti, Evdokia; Peeling, Peter; Dawson, Brian; Schumacher, Yorck O
2018-02-01
The haematological module of the Athlete's Biological Passport (ABP) has significantly impacted the prevalence of blood manipulations in elite sports. However, the ABP relies on a number of concentration-based markers of erythropoiesis, such as haemoglobin concentration ([Hb]), which are influenced by shifts in plasma volume (PV). Fluctuations in PV contribute to the majority of biological variance associated with volumetric ABP markers. Our laboratory recently identified a panel of common chemistry markers (from a simple blood test) capable of describing ca 67% of PV variance, presenting an applicable method to account for volume shifts within anti-doping practices. Here, this novel PV marker was included into the ABP adaptive model. Over a six-month period (one test per month), 33 healthy, active males provided blood samples and performed the CO-rebreathing method to record PV (control). In the final month participants performed a single maximal exercise effort to promote a PV shift (mean PV decrease -17%, 95% CI -9.75 to -18.13%). Applying the ABP adaptive model, individualized reference limits for [Hb] and the OFF-score were created, with and without the PV correction. With the PV correction, an average of 66% of [Hb] within-subject variance is explained, narrowing the predicted reference limits, and reducing the number of atypical ABP findings post-exercise. Despite an increase in sensitivity there was no observed loss of specificity with the addition of the PV correction. The novel PV marker presented here has the potential to improve the ABP's rate of correct doping detection by removing the confounding effects of PV variance. Copyright © 2017 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Kubis, Michael; Wise, Rich; Reijnen, Liesbeth; Viatkina, Katja; Jaenen, Patrick; Luca, Melisa; Mernier, Guillaume; Chahine, Charlotte; Hellin, David; Kam, Benjamin; Sobieski, Daniel; Vertommen, Johan; Mulkens, Jan; Dusa, Mircea; Dixit, Girish; Shamma, Nader; Leray, Philippe
2016-03-01
With shrinking design rules, the overall patterning requirements are getting aggressively tighter. For the 7-nm node and below, allowable CD uniformity variations are entering the Angstrom region (ref [1]). Optimizing inter- and intra-field CD uniformity of the final pattern requires a holistic tuning of all process steps. In previous work, CD control with either litho cluster or etch tool corrections has been discussed. Today, we present a holistic CD control approach, combining the correction capability of the etch tool with the correction capability of the exposure tool. The study is done on 10-nm logic node wafers, processed with a test vehicle stack patterning sequence. We include wafer-to-wafer and lot-to-lot variation and apply optical scatterometry to characterize the fingerprints. Making use of all available correction capabilities (lithography and etch), we investigated single application of exposure tool corrections and of etch tool corrections as well as combinations of both to reach the lowest CD uniformity. Results of the final pattern uniformity based on single and combined corrections are shown. We conclude on the application of this holistic lithography and etch optimization to 7nm High-Volume manufacturing, paving the way to ultimate within-wafer CD uniformity control.
1987-09-01
capillaries (4), blood volumes calculated from plasma volume measures must correct for label that has left the system between the time of the injected dose...Splenic sequestration and contraction are mediated by the autonomic nervous system and blood-borne agents (10). Sympathetic nerve fibers from the truncus...sympathlcus and parasympathetic neurons of the nervus vagus (cranial nerve X) innervate the celiac plexus (8, 11). A subdivision of the celiac plexus
Measurement of Crystalline Lens Volume During Accommodation in a Lens Stretcher.
Marussich, Lauren; Manns, Fabrice; Nankivil, Derek; Maceo Heilman, Bianca; Yao, Yue; Arrieta-Quintero, Esdras; Ho, Arthur; Augusteyn, Robert; Parel, Jean-Marie
2015-07-01
To determine if the lens volume changes during accommodation. The study used data acquired on 36 cynomolgus monkey lenses that were stretched in a stepwise fashion to simulate disaccommodation. At each step, stretching force and dioptric power were measured and a cross-sectional image of the lens was acquired using an optical coherence tomography system. Images were corrected for refractive distortions and lens volume was calculated assuming rotational symmetry. The average change in lens volume was calculated and the relation between volume change and power change, and between volume change and stretching force, were quantified. Linear regressions of volume-power and volume-force plots were calculated. The mean (± SD) volume in the unstretched (accommodated) state was 97 ± 8 mm3. On average, there was a small but statistically significant (P = 0.002) increase in measured lens volume with stretching. The mean change in lens volume was +0.8 ± 1.3 mm3. The mean volume-power and volume-load slopes were -0.018 ± 0.058 mm3/D and +0.16 ± 0.40 mm3/g. Lens volume remains effectively constant during accommodation, with changes that are less than 1% on average. This result supports a hypothesis that the change in lens shape with accommodation is accompanied by a redistribution of tissue within the capsular bag without significant compression of the lens contents or fluid exchange through the capsule.
Set-up uncertainties: online correction with X-ray volume imaging.
Kataria, Tejinder; Abhishek, Ashu; Chadha, Pranav; Nandigam, Janardhan
2011-01-01
To determine interfractional three-dimensional set-up errors using X-ray volumetric imaging (XVI). Between December 2007 and August 2009, 125 patients were taken up for image-guided radiotherapy using online XVI. After matching of reference and acquired volume view images, set-up errors in three translation directions were recorded and corrected online before treatment each day. Mean displacements, population systematic (Σ), and random (σ) errors were calculated and analyzed using SPSS (v16) software. Optimum clinical target volume (CTV) to planning target volume (PTV) margin was calculated using Van Herk's (2.5Σ + 0.7 σ) and Stroom's (2Σ + 0.7 σ) formula. Patients were grouped in 4 cohorts, namely brain, head and neck, thorax, and abdomen-pelvis. The mean vector displacement recorded were 0.18 cm, 0.15 cm, 0.36 cm, and 0.35 cm for brain, head and neck, thorax, and abdomen-pelvis, respectively. Analysis of individual mean set-up errors revealed good agreement with the proposed 0.3 cm isotropic margins for brain and 0.5 cm isotropic margins for head-neck. Similarly, 0.5 cm circumferential and 1 cm craniocaudal proposed margins were in agreement with thorax and abdomen-pelvic cases. The calculated mean displacements were well within CTV-PTV margin estimates of Van Herk (90% population coverage to minimum 95% prescribed dose) and Stroom (99% target volume coverage by 95% prescribed dose). Employing these individualized margins in a particular cohort ensure comparable target coverage as described in literature, which is further improved if XVI-aided set-up error detection and correction is used before treatment.
Numerical simulation of bubble deformation in magnetic fluids by finite volume method
NASA Astrophysics Data System (ADS)
Yamasaki, Haruhiko; Yamaguchi, Hiroshi
2017-06-01
Bubble deformation in magnetic fluids under magnetic field is investigated numerically by an interface capturing method. The numerical method consists of a coupled level-set and VOF (Volume of Fluid) method, combined with conservation CIP (Constrained Interpolation Profile) method with the self-correcting procedure. In the present study considering actual physical properties of magnetic fluid, bubble deformation under given uniform magnetic field is analyzed for internal magnetic field passing through a magnetic gaseous and liquid phase interface. The numerical results explain the mechanism of bubble deformation under presence of given magnetic field.
Berninger, Virginia W.; Gebregziabher, Mulugeta; Tsu, Loretta
2016-01-01
Abstract Meta-analysis of voxel-based morphometry dyslexia studies and direct analysis of 293 reading disability and control cases from six different research sites were performed to characterize defining gray matter features of reading disability. These analyses demonstrated consistently lower gray matter volume in left posterior superior temporal sulcus/middle temporal gyrus regions and left orbitofrontal gyrus/pars orbitalis regions. Gray matter volume within both of these regions significantly predicted individual variation in reading comprehension after correcting for multiple comparisons. These regional gray matter differences were observed across published studies and in the multisite dataset after controlling for potential age and gender effects, and despite increased anatomical variance in the reading disability group, but were not significant after controlling for total gray matter volume. Thus, the orbitofrontal and posterior superior temporal sulcus gray matter findings are relatively reliable effects that appear to be dependent on cases with low total gray matter volume. The results are considered in the context of genetics studies linking orbitofrontal and superior temporal sulcus regions to alleles that confer risk for reading disability. PMID:26835509
Mocz, G.
1995-01-01
Fuzzy cluster analysis has been applied to the 20 amino acids by using 65 physicochemical properties as a basis for classification. The clustering products, the fuzzy sets (i.e., classical sets with associated membership functions), have provided a new measure of amino acid similarities for use in protein folding studies. This work demonstrates that fuzzy sets of simple molecular attributes, when assigned to amino acid residues in a protein's sequence, can predict the secondary structure of the sequence with reasonable accuracy. An approach is presented for discriminating standard folding states, using near-optimum information splitting in half-overlapping segments of the sequence of assigned membership functions. The method is applied to a nonredundant set of 252 proteins and yields approximately 73% matching for correctly predicted and correctly rejected residues with approximately 60% overall success rate for the correctly recognized ones in three folding states: alpha-helix, beta-strand, and coil. The most useful attributes for discriminating these states appear to be related to size, polarity, and thermodynamic factors. Van der Waals volume, apparent average thickness of surrounding molecular free volume, and a measure of dimensionless surface electron density can explain approximately 95% of prediction results. hydrogen bonding and hydrophobicity induces do not yet enable clear clustering and prediction. PMID:7549882
Helical tomotherapy setup variations in canine nasal tumor patients immobilized with a bite block.
Kubicek, Lyndsay N; Seo, Songwon; Chappell, Richard J; Jeraj, Robert; Forrest, Lisa J
2012-01-01
The purpose of our study was to compare setup variation in four degrees of freedom (vertical, longitudinal, lateral, and roll) between canine nasal tumor patients immobilized with a mattress and bite block, versus a mattress alone. Our secondary aim was to define a clinical target volume (CTV) to planning target volume (PTV) expansion margin based on our mean systematic error values associated with nasal tumor patients immobilized by a mattress and bite block. We evaluated six parameters for setup corrections: systematic error, random error, patient-patient variation in systematic errors, the magnitude of patient-specific random errors (root mean square [RMS]), distance error, and the variation of setup corrections from zero shift. The variations in all parameters were statistically smaller in the group immobilized by a mattress and bite block. The mean setup corrections in the mattress and bite block group ranged from 0.91 mm to 1.59 mm for the translational errors and 0.5°. Although most veterinary radiation facilities do not have access to Image-guided radiotherapy (IGRT), we identified a need for more rigid fixation, established the value of adding IGRT to veterinary radiation therapy, and define the CTV-PTV setup error margin for canine nasal tumor patients immobilized in a mattress and bite block. © 2012 Veterinary Radiology & Ultrasound.
Shih, Y C; Tseng, C E; Lin, F-H; Liou, H H; Tseng, W Y I
2017-03-01
Unilateral mesial temporal lobe epilepsy and hippocampal sclerosis have structural and functional abnormalities in the mesial temporal regions. To gain insight into the pathophysiology of the epileptic network in mesial temporal lobe epilepsy with hippocampal sclerosis, we aimed to clarify the relationships between hippocampal atrophy and the altered connection between the hippocampus and the posterior cingulate cortex in patients with mesial temporal lobe epilepsy with hippocampal sclerosis. Fifteen patients with left mesial temporal lobe epilepsy with hippocampal sclerosis and 15 healthy controls were included in the study. Multicontrast MR imaging, including high-resolution T1WI, diffusion spectrum imaging, and resting-state fMRI, was performed to measure the hippocampal volume, structural connectivity of the inferior cingulum bundle, and intrinsic functional connectivity between the hippocampus and the posterior cingulate cortex, respectively. Compared with controls, patients had decreased left hippocampal volume (volume ratio of the hippocampus and controls, 0.366% ± 0.029%; patients, 0.277% ± 0.063%, corrected P = .002), structural connectivity of the bilateral inferior cingulum bundle (generalized fractional anisotropy, left: controls, 0.234 ± 0.020; patients, 0.193 ± 0.022, corrected P = .0001, right: controls, 0.226 ± 0.022; patients, 0.208 ± 0.017, corrected P = .047), and intrinsic functional connectivity between the left hippocampus and the left posterior cingulate cortex (averaged z-value: controls, 0.314 ± 0.152; patients, 0.166 ± 0.062). The left hippocampal volume correlated with structural connectivity positively (standardized β = 0.864, P = .001), but it had little correlation with intrinsic functional connectivity (standardized β = -0.329, P = .113). On the contralesional side, the hippocampal volume did not show any significant correlation with structural connectivity or intrinsic functional connectivity ( F 2,12 = 0.284, P = .757, R 2 = 0.045). In left mesial temporal lobe epilepsy with hippocampal sclerosis, the left inferior cingulum bundle undergoes degeneration in tandem with the left hippocampal volume, whereas intrinsic functional connectivity seems to react by compensating the loss of connectivity. Such insight might be helpful in understanding the development of the epileptic network in left mesial temporal lobe epilepsy with hippocampal sclerosis. © 2017 by American Journal of Neuroradiology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Merlin, Thibaut, E-mail: thibaut.merlin@telecom-bretagne.eu; Visvikis, Dimitris; Fernandez, Philippe
2015-02-15
Purpose: Partial volume effect (PVE) plays an important role in both qualitative and quantitative PET image accuracy, especially for small structures. A previously proposed voxelwise PVE correction method applied on PET reconstructed images involves the use of Lucy–Richardson deconvolution incorporating wavelet-based denoising to limit the associated propagation of noise. The aim of this study is to incorporate the deconvolution, coupled with the denoising step, directly inside the iterative reconstruction process to further improve PVE correction. Methods: The list-mode ordered subset expectation maximization (OSEM) algorithm has been modified accordingly with the application of the Lucy–Richardson deconvolution algorithm to the current estimationmore » of the image, at each reconstruction iteration. Acquisitions of the NEMA NU2-2001 IQ phantom were performed on a GE DRX PET/CT system to study the impact of incorporating the deconvolution inside the reconstruction [with and without the point spread function (PSF) model] in comparison to its application postreconstruction and to standard iterative reconstruction incorporating the PSF model. The impact of the denoising step was also evaluated. Images were semiquantitatively assessed by studying the trade-off between the intensity recovery and the noise level in the background estimated as relative standard deviation. Qualitative assessments of the developed methods were additionally performed on clinical cases. Results: Incorporating the deconvolution without denoising within the reconstruction achieved superior intensity recovery in comparison to both standard OSEM reconstruction integrating a PSF model and application of the deconvolution algorithm in a postreconstruction process. The addition of the denoising step permitted to limit the SNR degradation while preserving the intensity recovery. Conclusions: This study demonstrates the feasibility of incorporating the Lucy–Richardson deconvolution associated with a wavelet-based denoising in the reconstruction process to better correct for PVE. Future work includes further evaluations of the proposed method on clinical datasets and the use of improved PSF models.« less
MR-CBCT image-guided system for radiotherapy of orthotopic rat prostate tumors.
Chiu, Tsuicheng D; Arai, Tatsuya J; Campbell Iii, James; Jiang, Steve B; Mason, Ralph P; Stojadinovic, Strahinja
2018-01-01
Multi-modality image-guided radiotherapy is the standard of care in contemporary cancer management; however, it is not common in preclinical settings due to both hardware and software limitations. Soft tissue lesions, such as orthotopic prostate tumors, are difficult to identify using cone beam computed tomography (CBCT) imaging alone. In this study, we characterized a research magnetic resonance (MR) scanner for preclinical studies and created a protocol for combined MR-CBCT image-guided small animal radiotherapy. Two in-house dual-modality, MR and CBCT compatible, phantoms were designed and manufactured using 3D printing technology. The phantoms were used for quality assurance tests and to facilitate end-to-end testing for combined preclinical MR and CBCT based treatment planning. MR and CBCT images of the phantoms were acquired utilizing a Varian 4.7 T scanner and XRad-225Cx irradiator, respectively. The geometry distortion was assessed by comparing MR images to phantom blueprints and CBCT. The corrected MR scans were co-registered with CBCT and subsequently used for treatment planning. The fidelity of 3D printed phantoms compared to the blueprint design yielded favorable agreement as verified with the CBCT measurements. The geometric distortion, which varied between -5% and 11% throughout the scanning volume, was substantially reduced to within 0.4% after correction. The distortion free MR images were co-registered with the corresponding CBCT images and imported into a commercial treatment planning software SmART Plan. The planning target volume (PTV) was on average 19% smaller when contoured on the corrected MR-CBCT images relative to raw images without distortion correction. An MR-CBCT based preclinical workflow was successfully designed and implemented for small animal radiotherapy. Combined MR-CBCT image-guided radiotherapy for preclinical research potentially delivers enhanced relevance to human radiotherapy for various disease sites. This novel protocol is wide-ranging and not limited to the orthotopic prostate tumor study presented in the study.
Study of the Economic and Rehabilitative Aspects of Prison Industry. Technical Tasks and Results.
ERIC Educational Resources Information Center
National Inst. of Law Enforcement and Criminal Justice (Dept. of Justice/LEAA), Washington, DC.
This volume analyzes existing and proposed correctional industries in Connecticut. First, the results of a survey made to determine the potential inmate work force for prison industry are presented as inmate profiles, descriptions of inmate and supervisor attitudes, and analyses of parolees' employment and recidivism rates. In part 2, four…
Impact of Non-Gaussian Error Volumes on Conjunction Assessment Risk Analysis
NASA Technical Reports Server (NTRS)
Ghrist, Richard W.; Plakalovic, Dragan
2012-01-01
An understanding of how an initially Gaussian error volume becomes non-Gaussian over time is an important consideration for space-vehicle conjunction assessment. Traditional assumptions applied to the error volume artificially suppress the true non-Gaussian nature of the space-vehicle position uncertainties. For typical conjunction assessment objects, representation of the error volume by a state error covariance matrix in a Cartesian reference frame is a more significant limitation than is the assumption of linearized dynamics for propagating the error volume. In this study, the impact of each assumption is examined and isolated for each point in the volume. Limitations arising from representing the error volume in a Cartesian reference frame is corrected by employing a Monte Carlo approach to probability of collision (Pc), using equinoctial samples from the Cartesian position covariance at the time of closest approach (TCA) between the pair of space objects. A set of actual, higher risk (Pc >= 10 (exp -4)+) conjunction events in various low-Earth orbits using Monte Carlo methods are analyzed. The impact of non-Gaussian error volumes on Pc for these cases is minimal, even when the deviation from a Gaussian distribution is significant.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahmed, Faisal; Loma Linda University Medical Center, Department of Radiation Oncology, Loma Linda, CA; Sarkar, Vikren
Purpose: To evaluate radiation dose delivered to pelvic lymph nodes, if daily Image Guided Radiation Therapy (IGRT) was implemented with treatment shifts based on the primary site (primary clinical target volume [CTV]). Our secondary goal was to compare dosimetric coverage with patient outcomes. Materials and methods: A total of 10 female patients with gynecologic malignancies were evaluated retrospectively after completion of definitive intensity-modulated radiation therapy (IMRT) to their pelvic lymph nodes and primary tumor site. IGRT consisted of daily kilovoltage computed tomography (CT)-on-rails imaging fused with initial planning scans for position verification. The initial plan was created using Varian's Eclipsemore » treatment planning software. Patients were treated with a median radiation dose of 45 Gy (range: 37.5 to 50 Gy) to the primary volume and 45 Gy (range: 45 to 64.8 Gy) to nodal structures. One IGRT scan per week was randomly selected from each patient's treatment course and re-planned on the Eclipse treatment planning station. CTVs were recreated by fusion on the IGRT image series, and the patient's treatment plan was applied to the new image set to calculate delivered dose. We evaluated the minimum, maximum, and 95% dose coverage for primary and nodal structures. Reconstructed primary tumor volumes were recreated within 4.7% of initial planning volume (0.9% to 8.6%), and reconstructed nodal volumes were recreated to within 2.9% of initial planning volume (0.01% to 5.5%). Results: Dosimetric parameters averaged less than 10% (range: 1% to 9%) of the original planned dose (45 Gy) for primary and nodal volumes on all patients (n = 10). For all patients, ≥99.3% of the primary tumor volume received ≥ 95% the prescribed dose (V95%) and the average minimum dose was 96.1% of the prescribed dose. In evaluating nodal CTV coverage, ≥ 99.8% of the volume received ≥ 95% the prescribed dose and the average minimum dose was 93%. In evaluating individual IGRT sessions, we found that 6 patients had an estimated minimal nodal CTV dose less than 90% (range: 78 to 99%) of that planned. With a median follow-up of 42.5 months, 2 patients experienced systemic disease progression at an average of 19.6 months. One patient was found to have a local or regional failure with an average follow-up of 42 months. Conclusion: Using only 3 dimensional IGRT corrections in gynecological radiation allows excellent coverage of the primary target volume and good average nodal CTV coverage. If IGRT corrections are based on alignment to the primary tumor volume, and is only able to be corrected in 3 degrees, this can create situations in which nodal volumes may be under dosed. Utilizing multiple IGRT sessions appears to average out dose discrepancies over the course of treatment. The implication of underdosing in a single IGRT session needs further evaluation in future studies. Based on the concern of minimum dose to a nodal target volume, these findings may signal caution when using IGRT and IMRT in gynecological radiation patients. Possible techniques to overcome this situation may include averaging shifts between tumor and nodal volume, use of a treatment couch with 6° of freedom, deformable registration, or adaptive planning.« less
Barker, Charles E.; Dallegge, Todd A.
2005-01-01
Coal desorption techniques typically use the U.S. Bureau of Mines (USBM) canister-desorption method as described by Diamond and Levine (1981), Close and Erwin (1989), Ryan and Dawson (1993), McLennan and others (1994), Mavor and Nelson (1997) and Diamond and Schatzel (1998). However, the coal desorption canister designs historically used with this method have an inherent flaw that allows a significant gas-filled headspace bubble to remain in the canister that later has to be compensated for by correcting the measured desorbed gas volume with a mathematical headspace volume correction (McLennan and others, 1994; Mavor and Nelson, 1997).
Safety Education Handbook. Volume 2.
ERIC Educational Resources Information Center
Kansas State Dept. of Education, Topeka.
This is the second of three volumes of a safety guide developed to assist Kansas administrators and teachers in organizing, evaluating, and maintaining safety programs. It provides information to help them identify, assess, and correct unsafe conditions relating to equipment and facilities and ensure a safe and healthy environment for themselves…
Equipment for the Disabled. Volumes 1 - 4.
ERIC Educational Resources Information Center
Wilshere, E. Rosamond, Comp.
Four volumes of equipment for the disabled which can simplify their lives and those who live with them are presented. The authors have not included surgical, medical, therapeutic, corrective or gymnastic equipment in the publication. Voume one includes house adaptations and planning, beds and bed accessories, chairs, and wheelchairs and…
Safety Education Handbook. Volume 3.
ERIC Educational Resources Information Center
Kansas State Dept. of Education, Topeka.
This is the third of three volumes of a safety guide developed to assist Kansas administrators and teachers in organizing, evaluating, and maintaining safety programs. It provides information to help them identify, assess, and correct unsafe conditions relating to equipment and facilities and ensure a safe and healthy environment for themselves…
Depping, Malte S; Wolf, Nadine D; Vasic, Nenad; Sambataro, Fabio; Thomann, Philipp A; Christian Wolf, R
2015-03-15
Abnormal brain volume has been frequently demonstrated in major depressive disorder (MDD). It is unclear if these findings are specific for MDD since aberrant brain structure is also present in disorders with depressive comorbidity and affective dysregulation, such as borderline personality disorder (BPD). In this transdiagnostic study, we aimed to investigate if regional brain volume loss differentiates between MDD and BPD. Further, we tested for associations between brain volume and clinical variables within and between diagnostic groups. 22 Females with a DSM-IV diagnosis of MDD, 17 females with a DSM-IV diagnosis of BPD and without comorbid posttraumatic stress disorder, and 22 age-matched female healthy controls (HC) were investigated using magnetic resonance imaging. High-resolution structural data were analyzed using voxel-based morphometry. A significant (p<0.05, cluster-corrected) volume decrease of the anterior cingulate cortex (ACC) was found in MDD compared to HC, as opposed to volume decreases of the amygdala in BPD compared to both HC and MDD. Sensitivity and specificity of regional gray matter volume for a diagnosis of MDD were modest to fair. Amygdala volume was related to depressive symptoms across the entire patient sample. Potential limitations of this study include the modest sample size and the heterogeneous psychotropic drug treatment. ACC volume reduction is more pronounced in MDD with an intermediate degree of volume loss in BPD compared to HC. In contrast, amygdala volume loss is more pronounced in BPD compared to MDD, yet amygdala volume is associated with affective symptom expression in both disorders. Copyright © 2014 Elsevier B.V. All rights reserved.
A multifractal approach to space-filling recovery for PET quantification.
Willaime, Julien M Y; Aboagye, Eric O; Tsoumpas, Charalampos; Turkheimer, Federico E
2014-11-01
A new image-based methodology is developed for estimating the apparent space-filling properties of an object of interest in PET imaging without need for a robust segmentation step and used to recover accurate estimates of total lesion activity (TLA). A multifractal approach and the fractal dimension are proposed to recover the apparent space-filling index of a lesion (tumor volume, TV) embedded in nonzero background. A practical implementation is proposed, and the index is subsequently used with mean standardized uptake value (SUV mean) to correct TLA estimates obtained from approximate lesion contours. The methodology is illustrated on fractal and synthetic objects contaminated by partial volume effects (PVEs), validated on realistic (18)F-fluorodeoxyglucose PET simulations and tested for its robustness using a clinical (18)F-fluorothymidine PET test-retest dataset. TLA estimates were stable for a range of resolutions typical in PET oncology (4-6 mm). By contrast, the space-filling index and intensity estimates were resolution dependent. TLA was generally recovered within 15% of ground truth on postfiltered PET images affected by PVEs. Volumes were recovered within 15% variability in the repeatability study. Results indicated that TLA is a more robust index than other traditional metrics such as SUV mean or TV measurements across imaging protocols. The fractal procedure reported here is proposed as a simple and effective computational alternative to existing methodologies which require the incorporation of image preprocessing steps (i.e., partial volume correction and automatic segmentation) prior to quantification.
Yu, Tsung-Hsien; Tung, Yu-Chi; Chung, Kuo-Piao
2015-01-01
Background Volume-infection relationships have been examined for high-risk surgical procedures, but the conclusions remain controversial. The inconsistency might be due to inaccurate identification of cases of infection and different methods of categorizing service volumes. This study takes coronary artery bypass graft (CABG) surgical site infections (SSIs) as an example to examine whether a relationship exists between operation volumes and SSIs, when different SSIs case identification, definitions and categorization methods of operation volumes were implemented. Methods A population-based cross-sectional multilevel study was conducted. A total of 7,007 patients who received CABG surgery between 2006 and 2008 from19 medical centers in Taiwan were recruited. SSIs associated with CABG surgery were identified using International Classification of Diseases, 9th Revision, Clinical Modification (ICD-9 CM) codes and a Classification and Regression Trees (CART) model. Two definitions of surgeon and hospital operation volumes were used: (1) the cumulative CABG operation volumes within the study period; and (2) the cumulative CABG operation volumes in the previous one year before each CABG surgery. Operation volumes were further treated in three different ways: (1) a continuous variable; (2) a categorical variable based on the quartile; and (3) a data-driven categorical variable based on k-means clustering algorithm. Furthermore, subgroup analysis for comorbidities was also conducted. Results This study showed that hospital volumes were not significantly associated with SSIs, no matter which definitions or categorization methods of operation volume, or SSIs case identification approaches were used. On the contrary, the relationships between surgeon’s volumes varied. Most of the models demonstrated that the low-volume surgeons had higher risk than high-volume surgeons. Conclusion Surgeon volumes were more important than hospital volumes in exploring the relationship between CABG operation volumes and SSIs in Taiwan. However, the relationships were not robust. Definitions and categorization methods of operation volume and correct identification of SSIs are important issues for future research. PMID:26053035
NASA Technical Reports Server (NTRS)
Ahmed, H.
1981-01-01
The format of computer compatible tapes which contain LANDSAT 4 and D Prime thematic mapper data is defined. A complete specification of the CCT-AT (radiometric corrections applied and geometric matrices appended) and the CCT-PT (radiometric and geometric corrections) data formats is provided.
OPC care-area feedforwarding to MPC
NASA Astrophysics Data System (ADS)
Dillon, Brian; Peng, Yi-Hsing; Hamaji, Masakazu; Tsunoda, Dai; Muramatsu, Tomoyuki; Ohara, Shuichiro; Zou, Yi; Arnoux, Vincent; Baron, Stanislas; Zhang, Xiaolong
2016-10-01
Demand for mask process correction (MPC) is growing for leading-edge process nodes. MPC was originally intended to correct CD linearity for narrow assist features difficult to resolve on a photomask without any correction, but it has been extended to main features as process nodes have been shrinking. As past papers have observed, MPC shows improvements in photomask fidelity. Using advanced shape and dose corrections could give more improvements, especially at line-ends and corners. However, there is a dilemma on using such advanced corrections on full mask level because it increases data volume and run time. In addition, write time on variable shaped beam (VSB) writers also increases as the number of shots increases. Optical proximity correction (OPC) care-area defines circuit design locations that require high mask fidelity under mask writing process variations such as energy fluctuation. It is useful for MPC to switch its correction strategy and permit the use of advanced mask correction techniques in those local care-areas where they provide maximum wafer benefits. The use of mask correction techniques tailored to localized post-OPC design can result in similar desired level of data volume, run time, and write time. ASML Brion and NCS have jointly developed a method to feedforward the care-area information from Tachyon LMC to NDE-MPC to provide real benefit for improving both mask writing and wafer printing quality. This paper explains the detail of OPC care-area feedforwarding to MPC between ASML Brion and NCS, and shows the results. In addition, improvements on mask and wafer simulations are also shown. The results indicate that the worst process variation (PV) bands are reduced up to 37% for a 10nm tech node metal case.
The plasticity of extracellular fluid homeostasis in insects.
Beyenbach, Klaus W
2016-09-01
In chemistry, the ratio of all dissolved solutes to the solution's volume yields the osmotic concentration. The present Review uses this chemical perspective to examine how insects deal with challenges to extracellular fluid (ECF) volume, solute content and osmotic concentration (pressure). Solute/volume plots of the ECF (hemolymph) reveal that insects tolerate large changes in all three of these ECF variables. Challenges beyond those tolerances may be 'corrected' or 'compensated'. While a correction simply reverses the challenge, compensation accommodates the challenge with changes in the other two variables. Most insects osmoregulate by keeping ECF volume and osmotic concentration within a wide range of tolerance. Other insects osmoconform, allowing the ECF osmotic concentration to match the ambient osmotic concentration. Aphids are unique in handling solute and volume loads largely outside the ECF, in the lumen of the gut. This strategy may be related to the apparent absence of Malpighian tubules in aphids. Other insects can suspend ECF homeostasis altogether in order to survive extreme temperatures. Thus, ECF homeostasis in insects is highly dynamic and plastic, which may partly explain why insects remain the most successful class of animals in terms of both species number and biomass. © 2016. Published by The Company of Biologists Ltd.
Gay-Lussac Did Better Than He Knew
NASA Astrophysics Data System (ADS)
Holbrow, Charles H.; Amato, Joseph C.
2011-04-01
In his 1802 paper Joseph Louis Gay-Lussac reported the first definitive experimental evidence that many different gases exhibit the same fractional expansion of volume when heated. This property is known as Charles Law, Amontons Law, Dalton's Law, or the law of volumes. Gay-Lussac concluded from his experiments that many gases expand by 37.5% when heated from 0 ,oC to 100,oC. Although his result is within 2.5% of the modern value of 36.6% = 100/273.15, the discrepancy is surprising because his direct and simple experimental method allowed him to measure changes in volume with a precision of a few tenths of a percent. An examination of his original paper suggests, however, that he did not take into account that his measurements of the initial and final volumes of gas were made at slightly different pressures. With reasonable assumptions about the diagrams in his paper, one can use Pascal's law and the ideal gas law to correct the measured volumes so that they correspond to the same initial and final pressure. With this correction the results imply δV/V = .366. Gay-Lussac did better than he knew.
Sex differences in the correlation of emotional control and amygdala volumes in adolescents.
Blanton, Rebecca E; Chaplin, Tara M; Sinha, Rajita
2010-10-06
We examined male and female adolescents (8-18 years of age) that were scanned with structural brain MRI and looked for a correlation between volume of the right or the left amygdala and parent-reported ability of emotional control. A sex difference was found in the correlation between emotional control and the corrected volume of the left amygdala (that is the amygdala volume adjusted for total cranial volume). In girls, smaller left amygdala volumes were associated with better emotional control. In boys, larger left amygdala volumes were associated with better emotional control. These findings suggest that healthy girls and boys show a difference in the correlation between parental reports of emotional control and the left amygdala volume.
ERIC Educational Resources Information Center
Ferris, Dana R.
2004-01-01
The efficacy of teacher error/grammar correction in second language writing classes has been the subject of much controversy, including a published debate in an earlier volume of this journal [J. Second Language Writing 8 (1999) 1; J. Second Language Writing 8 (1999) 111]. In this paper, the state-of-the-art in error correction research in L2…
Costagli, Mauro; Waggoner, R Allen; Ueno, Kenichi; Tanaka, Keiji; Cheng, Kang
2009-04-15
In functional magnetic resonance imaging (fMRI), even subvoxel motion dramatically corrupts the blood oxygenation level-dependent (BOLD) signal, invalidating the assumption that intensity variation in time is primarily due to neuronal activity. Thus, correction of the subject's head movements is a fundamental step to be performed prior to data analysis. Most motion correction techniques register a series of volumes assuming that rigid body motion, characterized by rotational and translational parameters, occurs. Unlike the most widely used applications for fMRI data processing, which correct motion in the image domain by numerically estimating rotational and translational components simultaneously, the algorithm presented here operates in a three-dimensional k-space, to decouple and correct rotations and translations independently, offering new ways and more flexible procedures to estimate the parameters of interest. We developed an implementation of this method in MATLAB, and tested it on both simulated and experimental data. Its performance was quantified in terms of square differences and center of mass stability across time. Our data show that the algorithm proposed here successfully corrects for rigid-body motion, and its employment in future fMRI studies is feasible and promising.
Report on the FY 1986 Activities of the Defense Science Study Group. Volume 1.
1987-05-01
Reactors Improved Techniques for Wavefront Sensing and Correction in Adaptive Optics Hypervelocity Launchers Underground Facilities 0 Automated...oceanography and sound propagation in partially coherent media such as the turbulent ocean. There are large fixed arrays such as the Sound Surveillance System...Aircraft Continuous Patrol Aircraft Miscellaneous Studies Review of the Plutonium Special Isotope Separation Program of the DOE 4r Fusion Fission Hybrid
Towards an explicit model of large field inflation
NASA Astrophysics Data System (ADS)
Dorronsoro, Juan Diaz; Schillo, Marjorie
2018-05-01
The unwinding inflation mechanism is studied in a type IIB flux compactification where all moduli are stabilized using flux, non-perturbative effects, and the leading α' corrections of the large volume scenario. We consider the backreaction on the geometry due to the presence of anti-D3 branes as well as the backreaction of inflation on the Kähler moduli, and compute the resulting corrections to the slow-roll potential. By taking large flux numbers, we are able to find inflationary epochs where backreaction effects are under control, the inflaton traverses a super-Planckian field range, and the resulting amplitude of scalar perturbations is consistent with observation.
Zhao, Zhihui; Liu, Zhen; Hu, Zongshan; Tseng, Changchun; Li, Jie; Pan, Wei; Qiu, Yong; Zhu, Zezhang
2018-03-16
The purpose of this study was to analyze the occurrence of PE after intra-operative O-arm navigation-assisted surgery and determine whether the post-operative PE incidence could be decreased by using O-arm navigation as compared to conventional free-hand technique. A cohort of 27 patients with spinal deformity who were operated upon with an O-arm navigated system (group A) between 2013 and 2016 were enrolled in the study. A total of 27 curve-matched patients treated by conventional free-hand technique were included as the control group (group B). Whole spine posterior-anterior and lateral radiographs, and CT scans were taken pre and post-operation. Radiologic parameters and volume of PE were measured and compared between the two groups. There were no significant differences in age, Cobb angle, and sagittal contour between the two groups pre-operatively. The mean total volume of post-operative PE was significantly larger in the free-hand group (p < 0.001). In the O-arm group, 59 malpositioned screws were identified in 22 patients. In the free-hand group, 88 malpositioned screws were found among 26 patients. The screw perforation rate was higher in the free-hand group than in the O-arm group (p = 0.007). In the O-arm group, the mean volume of PE was significantly larger among patients with malpositioned screws than those without malpositioned screws (p < 0.001), as well as in the free-hand group. The volume of PE after correction surgery can be significantly decreased by application of O-arm navigation system as compared to conventional free-hand technique. We ascribed the improvement to the accuracy of screw implantation navigated by O-arm.
Olfactocentric paralimbic cortex morphology in adolescents with bipolar disorder
Wang, Fei; Kalmar, Jessica H.; Womer, Fay Y.; Edmiston, Erin E.; Chepenik, Lara G.; Chen, Rachel; Spencer, Linda
2011-01-01
The olfactocentric paralimbic cortex plays a critical role in the regulation of emotional and neurovegetative functions that are disrupted in core features of bipolar disorder. Adolescence is thought to be a critical period in both the maturation of the olfactocentric paralimbic cortex and in the emergence of bipolar disorder pathology. Together, these factors implicate a central role for the olfactocentric paralimbic cortex in the development of bipolar disorder and suggest that abnormalities in this cortex may be expressed by adolescence in the disorder. We tested the hypothesis that differences in olfactocentric paralimbic cortex structure are a morphological feature in adolescents with bipolar disorder. Subjects included 118 adolescents (41 with bipolar disorder and 77 healthy controls). Cortical grey matter volume differences between adolescents with and without bipolar disorder were assessed with voxel-based morphometry analyses of high-resolution structural magnetic resonance imaging scans. Compared with healthy comparison adolescents, adolescents with bipolar disorder demonstrated significant volume decreases in olfactocentric paralimbic regions, including orbitofrontal, insular and temporopolar cortices. Findings in these regions survived small volume correction (P < 0.05, corrected). Volume decreases in adolescents with bipolar disorder were also noted in inferior prefrontal and superior temporal gyri and cerebellum. The findings suggest that abnormalities in the morphology of the olfactocentric paralimbic cortex may contribute to the bipolar disorder phenotype that emerges in adolescence. The morphological development of the olfactocentric paralimbic cortex has received little study. The importance of these cortices in emotional and social development, and support for a central role for these cortices in the development of bipolar disorder, suggest that study of the development of these cortices in health and in bipolar disorder is critically needed. PMID:21666263
Olfactocentric paralimbic cortex morphology in adolescents with bipolar disorder.
Wang, Fei; Kalmar, Jessica H; Womer, Fay Y; Edmiston, Erin E; Chepenik, Lara G; Chen, Rachel; Spencer, Linda; Blumberg, Hilary P
2011-07-01
The olfactocentric paralimbic cortex plays a critical role in the regulation of emotional and neurovegetative functions that are disrupted in core features of bipolar disorder. Adolescence is thought to be a critical period in both the maturation of the olfactocentric paralimbic cortex and in the emergence of bipolar disorder pathology. Together, these factors implicate a central role for the olfactocentric paralimbic cortex in the development of bipolar disorder and suggest that abnormalities in this cortex may be expressed by adolescence in the disorder. We tested the hypothesis that differences in olfactocentric paralimbic cortex structure are a morphological feature in adolescents with bipolar disorder. Subjects included 118 adolescents (41 with bipolar disorder and 77 healthy controls). Cortical grey matter volume differences between adolescents with and without bipolar disorder were assessed with voxel-based morphometry analyses of high-resolution structural magnetic resonance imaging scans. Compared with healthy comparison adolescents, adolescents with bipolar disorder demonstrated significant volume decreases in olfactocentric paralimbic regions, including orbitofrontal, insular and temporopolar cortices. Findings in these regions survived small volume correction (P < 0.05, corrected). Volume decreases in adolescents with bipolar disorder were also noted in inferior prefrontal and superior temporal gyri and cerebellum. The findings suggest that abnormalities in the morphology of the olfactocentric paralimbic cortex may contribute to the bipolar disorder phenotype that emerges in adolescence. The morphological development of the olfactocentric paralimbic cortex has received little study. The importance of these cortices in emotional and social development, and support for a central role for these cortices in the development of bipolar disorder, suggest that study of the development of these cortices in health and in bipolar disorder is critically needed.
White Matter Volume Predicts Language Development in Congenital Heart Disease.
Rollins, Caitlin K; Asaro, Lisa A; Akhondi-Asl, Alireza; Kussman, Barry D; Rivkin, Michael J; Bellinger, David C; Warfield, Simon K; Wypij, David; Newburger, Jane W; Soul, Janet S
2017-02-01
To determine whether brain volume is reduced at 1 year of age and whether these volumes are associated with neurodevelopment in biventricular congenital heart disease (CHD) repaired in infancy. Infants with biventricular CHD (n = 48) underwent brain magnetic resonance imaging (MRI) and neurodevelopmental testing with the Bayley Scales of Infant Development-II and the MacArthur-Bates Communicative Development Inventories at 1 year of age. A multitemplate based probabilistic segmentation algorithm was applied to volumetric MRI data. We compared volumes with those of 13 healthy control infants of comparable ages. In the group with CHD, we measured Spearman correlations between neurodevelopmental outcomes and the residuals from linear regression of the volumes on corrected chronological age at MRI and sex. Compared with controls, infants with CHD had reductions of 54 mL in total brain (P = .009), 40 mL in cerebral white matter (P <.001), and 1.2 mL in brainstem (P = .003) volumes. Within the group with CHD, brain volumes were not correlated with Bayley Scales of Infant Development-II scores but did correlate positively with MacArthur-Bates Communicative Development Inventory language development. Infants with biventricular CHD show total brain volume reductions at 1 year of age, driven by differences in cerebral white matter. White matter volume correlates with language development, but not broader developmental indices. These findings suggest that abnormalities in white matter development detected months after corrective heart surgery may contribute to language impairment. ClinicalTrials.gov: NCT00006183. Copyright © 2016 Elsevier Inc. All rights reserved.
What Gay-Lussac didn't tell us
NASA Astrophysics Data System (ADS)
Holbrow, C. H.; Amato, J. C.
2011-01-01
Gay-Lussac's 1801 experiments establishing the law of volumes for gases are brilliantly simple, and he described them with a level of detail that was new to physics writing. But he did not present his actual measurements or tell us how he analyzed them to conclude that between 0 to 100 °C, a volume of any gas will expand by about 37.5%. We review his experiments and conclude that he measured initial and final volumes at slightly different pressures. By using the gas laws and his apparatus diagrams, we corrected his data so that they correspond to constant pressure. His corrected results give ΔV/V=36.6%, the currently accepted value for nearly ideal gases. Aside from their intrinsic interest, our analyses can provide students intriguing applications of the gas laws and Pascal's law and motivate them to consider Pascal's paradox. We also note the influence of ballooning and of the French Revolution on Gay-Lussac.
Analysis of Prostate Patient Setup and Tracking Data: Potential Intervention Strategies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Su Zhong, E-mail: zsu@floridaproton.org; Zhang Lisha; Murphy, Martin
Purpose: To evaluate the setup, interfraction, and intrafraction organ motion error distributions and simulate intrafraction intervention strategies for prostate radiotherapy. Methods and Materials: A total of 17 patients underwent treatment setup and were monitored using the Calypso system during radiotherapy. On average, the prostate tracking measurements were performed for 8 min/fraction for 28 fractions for each patient. For both patient couch shift data and intrafraction organ motion data, the systematic and random errors were obtained from the patient population. The planning target volume margins were calculated using the van Herk formula. Two intervention strategies were simulated using the tracking data:more » the deviation threshold and period. The related planning target volume margins, time costs, and prostate position 'fluctuation' were presented. Results: The required treatment margin for the left-right, superoinferior, and anteroposterior axes was 8.4, 10.8, and 14.7 mm for skin mark-only setup and 1.3, 2.3, and 2.8 mm using the on-line setup correction, respectively. Prostate motion significantly correlated among the superoinferior and anteroposterior directions. Of the 17 patients, 14 had prostate motion within 5 mm of the initial setup position for {>=}91.6% of the total tracking time. The treatment margin decreased to 1.1, 1.8, and 2.3 mm with a 3-mm threshold correction and to 0.5, 1.0, and 1.5 mm with an every-2-min correction in the left-right, superoinferior, and anteroposterior directions, respectively. The periodic corrections significantly increase the treatment time and increased the number of instances when the setup correction was made during transient excursions. Conclusions: The residual systematic and random error due to intrafraction prostate motion is small after on-line setup correction. Threshold-based and time-based intervention strategies both reduced the planning target volume margins. The time-based strategies increased the treatment time and the in-fraction position fluctuation.« less
Scaling Theory of Entanglement at the Many-Body Localization Transition.
Dumitrescu, Philipp T; Vasseur, Romain; Potter, Andrew C
2017-09-15
We study the universal properties of eigenstate entanglement entropy across the transition between many-body localized (MBL) and thermal phases. We develop an improved real space renormalization group approach that enables numerical simulation of large system sizes and systematic extrapolation to the infinite system size limit. For systems smaller than the correlation length, the average entanglement follows a subthermal volume law, whose coefficient is a universal scaling function. The full distribution of entanglement follows a universal scaling form, and exhibits a bimodal structure that produces universal subleading power-law corrections to the leading volume law. For systems larger than the correlation length, the short interval entanglement exhibits a discontinuous jump at the transition from fully thermal volume law on the thermal side, to pure area law on the MBL side.
Quantifying Rigid and Nonrigid Motion of Liver Tumors During Stereotactic Body Radiation Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Qianyi, E-mail: xuqianyi@gmail.com; Hanna, George; Grimm, Jimm
2014-09-01
Purpose: To quantify rigid and nonrigid motion of liver tumors using reconstructed 3-dimensional (3D) fiducials from stereo imaging during CyberKnife-based stereotactic body radiation therapy (SBRT). Methods and Materials: Twenty-three liver patients treated with 3 fractions of SBRT were used in this study. After 2 orthogonal kilovoltage images were taken during treatment, the 3D locations of the fiducials were generated by the CyberKnife system and validated using geometric derivations. A total of 4824 pairs of kilovoltage images from start to end of treatment were analyzed. For rigid motion, the rotational angles and translational shifts were reported by aligning 3D fiducial groupsmore » from different image pairs, using least-squares fitting. For nonrigid motion, we quantified interfractional tumor volume variations by using the proportional volume derived from the fiducials, which correlates to the sum of interfiducial distances. The individual fiducial displacements were also reported (1) after rigid corrections and (2) without angle corrections. Results: The proportional volume derived by the fiducials demonstrated a volume-increasing trend in the second (101.9% ± 3.6%) and third (101.0 ± 5.9%) fractions among most patients, possibly due to radiation-induced edema. For all patients, the translational shifts in left-right, anteroposterior, and superoinferior directions were 2.1 ± 2.3 mm, 2.9 ± 2.8 mm, and 6.4 ± 5.5 mm, respectively. The greatest translational shifts occurred in the superoinferior direction, likely due to respiratory motion from the diaphragm. The rotational angles in roll, pitch, and yaw were 1.2° ± 1.8°, 1.8° ± 2.4°, and 1.7° ± 2.1°, respectively. The 3D individual fiducial displacements with rigid corrections were 0.2 ± 0.2 mm and increased to 0.5 ± 0.4 mm without rotational corrections. Conclusions: Accurate 3D locations of internal fiducials can be reconstructed from stereo imaging during treatment. As an effective surrogate to tumor motion, fiducials provide a close estimation of both rigid and nonrigid motion of liver tumors. The reported displacements could be further utilized for tumor margin definition and motion management in conventional linear accelerator–based liver SBRT.« less
Baun, Christina; Falch, Kirsten; Gerke, Oke; Hansen, Jeanette; Nguyen, Tram; Alavi, Abass; Høilund-Carlsen, Poul-Flemming; Hildebrandt, Malene G
2018-05-09
Several studies have shown the advantage of delayed-time-point imaging with 18F-FDG-PET/CT to distinguish malignant from benign uptake. This may be relevant in cancer diseases with low metabolism, such as breast cancer. We aimed at examining the change in SUV from 1 h (1h) to 3 h (3h) time-point imaging in local and distant lesions in patients with recurrent breast cancer. Furthermore, we investigated the effect of partial volume correction in the different types of metastases, using semi-automatic quantitative software (ROVER™). One-hundred and two patients with suspected breast cancer recurrence underwent whole-body PET/CT scans 1h and 3h after FDG injection. Semi-quantitative standardised uptake values (SUVmax, SUVmean) and partial volume corrected SUVmean (cSUVmean), were estimated in malignant lesions, and as reference in healthy liver tissue. The change in quantitative measures from 1h to 3h was calculated, and SUVmean was compared to cSUVmean. Metastases were verified by biopsy. Of the 102 included patients, 41 had verified recurrent disease with in median 15 lesions (range 1-70) amounting to a total of 337 malignant lesions included in the analysis. SUVmax of malignant lesions increased from 6.4 ± 3.4 [0.9-19.7] (mean ± SD, min and max) at 1h to 8.1 ± 4.4 [0.7-29.7] at 3h. SUVmax in breast, lung, lymph node and bone lesions increased significantly (p < 0.0001) between 1h and 3h by on average 25, 40, 33, and 27%, respectively. A similar pattern was observed with (uncorrected) SUVmean. Partial volume correction increased SUVmean significantly, by 63 and 71% at 1h and 3h imaging, respectively. The highest impact was in breast lesions at 3h, where cSUVmean increased by 87% compared to SUVmean. SUVs increased from 1h to 3h in malignant lesions, SUVs of distant recurrence were in general about twice as high as those of local recurrence. Partial volume correction caused significant increases in these values. However, it is questionable, if these relatively modest quantitative advances of 3h imaging are sufficient to warrant delayed imaging in this patient group. ClinicalTrails.gov NCT01552655 . Registered 28 February 2012, partly retrospectively registered.
Irradiation of the prostate and pelvic lymph nodes with an adaptive algorithm
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hwang, A. B.; Chen, J.; Nguyen, T. B.
2012-02-15
Purpose: The simultaneous treatment of pelvic lymph nodes and the prostate in radiotherapy for prostate cancer is complicated by the independent motion of these two target volumes. In this work, the authors study a method to adapt intensity modulated radiation therapy (IMRT) treatment plans so as to compensate for this motion by adaptively morphing the multileaf collimator apertures and adjusting the segment weights. Methods: The study used CT images, tumor volumes, and normal tissue contours from patients treated in our institution. An IMRT treatment plan was then created using direct aperture optimization to deliver 45 Gy to the pelvic lymphmore » nodes and 50 Gy to the prostate and seminal vesicles. The prostate target volume was then shifted in either the anterior-posterior direction or in the superior-inferior direction. The treatment plan was adapted by adjusting the aperture shapes with or without re-optimizing the segment weighting. The dose to the target volumes was then determined for the adapted plan. Results: Without compensation for prostate motion, 1 cm shifts of the prostate resulted in an average decrease of 14% in D-95%. If the isocenter is simply shifted to match the prostate motion, the prostate receives the correct dose but the pelvic lymph nodes are underdosed by 14% {+-} 6%. The use of adaptive morphing (with or without segment weight optimization) reduces the average change in D-95% to less than 5% for both the pelvic lymph nodes and the prostate. Conclusions: Adaptive morphing with and without segment weight optimization can be used to compensate for the independent motion of the prostate and lymph nodes when combined with daily imaging or other methods to track the prostate motion. This method allows the delivery of the correct dose to both the prostate and lymph nodes with only small changes to the dose delivered to the target volumes.« less
NASA Astrophysics Data System (ADS)
Dumouchel, Tyler; Thorn, Stephanie; Kordos, Myra; DaSilva, Jean; Beanlands, Rob S. B.; deKemp, Robert A.
2012-07-01
Quantification in cardiac mouse positron emission tomography (PET) imaging is limited by the imaging spatial resolution. Spillover of left ventricle (LV) myocardial activity into adjacent organs results in partial volume (PV) losses leading to underestimation of myocardial activity. A PV correction method was developed to restore accuracy of the activity distribution for FDG mouse imaging. The PV correction model was based on convolving an LV image estimate with a 3D point spread function. The LV model was described regionally by a five-parameter profile including myocardial, background and blood activities which were separated into three compartments by the endocardial radius and myocardium wall thickness. The PV correction was tested with digital simulations and a physical 3D mouse LV phantom. In vivo cardiac FDG mouse PET imaging was also performed. Following imaging, the mice were sacrificed and the tracer biodistribution in the LV and liver tissue was measured using a gamma-counter. The PV correction algorithm improved recovery from 50% to within 5% of the truth for the simulated and measured phantom data and image uniformity by 5-13%. The PV correction algorithm improved the mean myocardial LV recovery from 0.56 (0.54) to 1.13 (1.10) without (with) scatter and attenuation corrections. The mean image uniformity was improved from 26% (26%) to 17% (16%) without (with) scatter and attenuation corrections applied. Scatter and attenuation corrections were not observed to significantly impact PV-corrected myocardial recovery or image uniformity. Image-based PV correction algorithm can increase the accuracy of PET image activity and improve the uniformity of the activity distribution in normal mice. The algorithm may be applied using different tracers, in transgenic models that affect myocardial uptake, or in different species provided there is sufficient image quality and similar contrast between the myocardium and surrounding structures.
Zhou, Lihong; Yuan, Liming; Thomas, Rick; Iannacchione, Anthony
2017-12-01
When there are installations of air velocity sensors in the mining industry for real-time airflow monitoring, a problem exists with how the monitored air velocity at a fixed location corresponds to the average air velocity, which is used to determine the volume flow rate of air in an entry with the cross-sectional area. Correction factors have been practically employed to convert a measured centerline air velocity to the average air velocity. However, studies on the recommended correction factors of the sensor-measured air velocity to the average air velocity at cross sections are still lacking. A comprehensive airflow measurement was made at the Safety Research Coal Mine, Bruceton, PA, using three measuring methods including single-point reading, moving traverse, and fixed-point traverse. The air velocity distribution at each measuring station was analyzed using an air velocity contour map generated with Surfer ® . The correction factors at each measuring station for both the centerline and the sensor location were calculated and are discussed.
Yuan, Liming; Thomas, Rick; Iannacchione, Anthony
2017-01-01
When there are installations of air velocity sensors in the mining industry for real-time airflow monitoring, a problem exists with how the monitored air velocity at a fixed location corresponds to the average air velocity, which is used to determine the volume flow rate of air in an entry with the cross-sectional area. Correction factors have been practically employed to convert a measured centerline air velocity to the average air velocity. However, studies on the recommended correction factors of the sensor-measured air velocity to the average air velocity at cross sections are still lacking. A comprehensive airflow measurement was made at the Safety Research Coal Mine, Bruceton, PA, using three measuring methods including single-point reading, moving traverse, and fixed-point traverse. The air velocity distribution at each measuring station was analyzed using an air velocity contour map generated with Surfer®. The correction factors at each measuring station for both the centerline and the sensor location were calculated and are discussed. PMID:29201495
Cerqua, Sandro; Angelucci, Francesco
2013-08-01
In a minority of patients undergoing liposuction, superficial irregularities (or skin depression) in the operated area may occur. Macrolane is a gel composed of hyaluronic acid (HA), used for volume restoration of soft tissues. In this study, the authors investigated the effectiveness, maintenance, and safety of Macrolane as a "non-surgical" treatment to correct skin depression after liposuction. Twelve female patients were included. Macrolane was injected at a subdermal superficial plane using an intramuscular or spinal needle. In all patients, Macrolane was successful in correcting skin depression. No relevant side effects were observed. At 8 months post-injection, a persistence of correction of 60-70% was still present in 90% of the patients. In conclusion, Macrolane filler injections are a predictable, safe, and long-lasting non-surgical procedure to fill contour defects that arise after liposuction, and represent a good option for patients who refuse to undergo an additional surgery to fill the arisen skin depressions.
Nonergodicity of microfine binary systems
NASA Astrophysics Data System (ADS)
Son, L. D.; Sidorov, V. E.; Popel', P. S.; Shul'gin, D. B.
2016-02-01
The correction to the equation of state that is related to the nonergodicity of diffusion dynamics is discussed for a binary solid solution with a limited solubility. It is asserted that, apart from standard thermodynamic variables (temperature, volume, concentration), this correction should be taken into account in the form of the average local chemical potential fluctuations associated with microheterogeneity in order to plot a phase diagram. It is shown that a low value of this correction lowers the miscibility gap and that this gap splits when this correction increases. This situation is discussed for eutectic systems and Ga-Pb, Fe-Cu, and Cu-Zr alloys.
An Allometric Analysis of Sex and Sex Chromosome Dosage Effects on Subcortical Anatomy in Humans.
Reardon, Paul Kirkpatrick; Clasen, Liv; Giedd, Jay N; Blumenthal, Jonathan; Lerch, Jason P; Chakravarty, M Mallar; Raznahan, Armin
2016-02-24
Structural neuroimaging of humans with typical and atypical sex-chromosome complements has established the marked influence of both Yand X-/Y-chromosome dosage on total brain volume (TBV) and identified potential cortical substrates for the psychiatric phenotypes associated with sex-chromosome aneuploidy (SCA). Here, in a cohort of 354 humans with varying karyotypes (XX, XY, XXX, XXY, XYY, XXYY, XXXXY), we investigate sex and SCA effects on subcortical size and shape; focusing on the striatum, pallidum and thalamus. We find large effect-size differences in the volume and shape of all three structures as a function of sex and SCA. We correct for TBV effects with a novel allometric method harnessing normative scaling rules for subcortical size and shape in humans, which we derive here for the first time. We show that all three subcortical volumes scale sublinearly with TBV among healthy humans, mirroring known relationships between subcortical volume and TBV among species. Traditional TBV correction methods assume linear scaling and can therefore invert or exaggerate sex and SCA effects on subcortical anatomy. Allometric analysis restricts sex-differences to: (1) greater pallidal volume (PV) in males, and (2) relative caudate head expansion and ventral striatum contraction in females. Allometric analysis of SCA reveals that supernumerary X- and Y-chromosomes both cause disproportionate reductions in PV, and coordinated deformations of striatopallidal shape. Our study provides a novel understanding of sex and sex-chromosome dosage effects on subcortical organization, using an allometric approach that can be generalized to other basic and clinical structural neuroimaging settings. Copyright © 2016 the authors 0270-6474/16/362438-11$15.00/0.
Decreased cerebral perfusion in Duchenne muscular dystrophy patients.
Doorenweerd, Nathalie; Dumas, Eve M; Ghariq, Eidrees; Schmid, Sophie; Straathof, Chiara S M; Roest, Arno A W; Wokke, Beatrijs H; van Zwet, Erik W; Webb, Andrew G; Hendriksen, Jos G M; van Buchem, Mark A; Verschuuren, Jan J G M; Asllani, Iris; Niks, Erik H; van Osch, Matthias J P; Kan, Hermien E
2017-01-01
Duchenne muscular dystrophy is caused by dystrophin gene mutations which lead to the absence of the protein dystrophin. A significant proportion of patients suffer from learning and behavioural disabilities, in addition to muscle weakness. We have previously shown that these patients have a smaller total brain and grey matter volume, and altered white matter microstructure compared to healthy controls. Patients with more distal gene mutations, predicted to affect dystrophin isoforms Dp140 and Dp427, showed greater grey matter reduction. Now, we studied if cerebral blood flow in Duchenne muscular dystrophy patients is altered, since cerebral expression of dystrophin also occurs in vascular endothelial cells and astrocytes associated with cerebral vasculature. T1-weighted anatomical and pseudo-continuous arterial spin labeling cerebral blood flow images were obtained from 26 patients and 19 age-matched controls (ages 8-18 years) on a 3 tesla MRI scanner. Group comparisons of cerebral blood flow were made with and without correcting for grey matter volume using partial volume correction. Results showed that patients had a lower cerebral blood flow than controls (40.0 ± 6.4 and 47.8 ± 6.3 mL/100 g/min respectively, p = 0.0002). This reduction was independent of grey matter volume, suggesting that they are two different aspects of the pathophysiology. Cerebral blood flow was lowest in patients lacking Dp140. There was no difference in CBF between ambulant and non-ambulant patients. Only three patients showed a reduced left ventricular ejection fraction. No correlation between cerebral blood flow and age was found. Our results indicate that cerebral perfusion is reduced in Duchenne muscular dystrophy patients independent of the reduced grey matter volume. Copyright © 2016 Elsevier B.V. All rights reserved.
Lázaro, L; Ortiz, A G; Calvo, A; Ortiz, A E; Moreno, E; Morer, A; Calvo, R; Bargallo, N
2014-10-03
The aims of this study were to identify gray matter (GM) and white matter (WM) volume abnormalities in pediatric obsessive-compulsive patients, to examine their relationship between these abnormalities and the severity of disorder, and to explore whether they could be explained by the different symptom dimensions. 62 child and adolescent OCD patients (11-18years old) and 46 healthy subjects of the same gender and similar age and estimated intellectual quotient were assessed by means of psychopathological scales and magnetic resonance imaging (MRI). Axial three-dimensional T1-weighted images were obtained in a 3T scanner and analyzed using optimized voxel-based morphometry (VBM). Compared with healthy controls, OCD patients showed lower white matter (WM) volume in the left dorsolateral and cingulate regions involving the superior and middle frontal gyri and anterior cingulate gyrus (t=4.35, p=0.049 FWE (family wise error)-corrected). There was no significant correlation between WM and the severity of obsessive-compulsive symptomatology. There were no regions with lower gray matter (GM) volume in OCD patients than in controls. Compared with healthy controls, only the "harm/checking" OCD dimension showed a cluster with a near significant decrease in WM volume in the right superior temporal gyrus extending into the insula (t=5.61, p=.056 FWE-corrected). The evidence suggests that abnormalities in the dorsolateral prefrontal cortex, anterior cingulate cortex, temporal and limbic regions play a central role in the pathophysiology of OCD. Moreover, regional brain volumes in OCD may vary depending on specific OCD symptom dimensions, indicating the clinical heterogeneity of the condition. Copyright © 2014 Elsevier Inc. All rights reserved.
Quantitative study of FORC diagrams in thermally corrected Stoner- Wohlfarth nanoparticles systems
NASA Astrophysics Data System (ADS)
De Biasi, E.; Curiale, J.; Zysler, R. D.
2016-12-01
The use of FORC diagrams is becoming increasingly popular among researchers devoted to magnetism and magnetic materials. However, a thorough interpretation of this kind of diagrams, in order to achieve quantitative information, requires an appropriate model of the studied system. For that reason most of the FORC studies are used for a qualitative analysis. In magnetic systems thermal fluctuations "blur" the signatures of the anisotropy, volume and particle interactions distributions, therefore thermal effects in nanoparticles systems conspire against a proper interpretation and analysis of these diagrams. Motivated by this fact, we have quantitatively studied the degree of accuracy of the information extracted from FORC diagrams for the special case of single-domain thermal corrected Stoner- Wohlfarth (easy axes along the external field orientation) nanoparticles systems. In this work, the starting point is an analytical model that describes the behavior of a magnetic nanoparticles system as a function of field, anisotropy, temperature and measurement time. In order to study the quantitative degree of accuracy of our model, we built FORC diagrams for different archetypical cases of magnetic nanoparticles. Our results show that from the quantitative information obtained from the diagrams, under the hypotheses of the proposed model, is possible to recover the features of the original system with accuracy above 95%. This accuracy is improved at low temperatures and also it is possible to access to the anisotropy distribution directly from the FORC coercive field profile. Indeed, our simulations predict that the volume distribution plays a secondary role being the mean value and its deviation the only important parameters. Therefore it is possible to obtain an accurate result for the inversion and interaction fields despite the features of the volume distribution.
Real-Time Microfluidic Blood-Counting System for PET and SPECT Preclinical Pharmacokinetic Studies.
Convert, Laurence; Lebel, Réjean; Gascon, Suzanne; Fontaine, Réjean; Pratte, Jean-François; Charette, Paul; Aimez, Vincent; Lecomte, Roger
2016-09-01
Small-animal nuclear imaging modalities have become essential tools in the development process of new drugs, diagnostic procedures, and therapies. Quantification of metabolic or physiologic parameters is based on pharmacokinetic modeling of radiotracer biodistribution, which requires the blood input function in addition to tissue images. Such measurements are challenging in small animals because of their small blood volume. In this work, we propose a microfluidic counting system to monitor rodent blood radioactivity in real time, with high efficiency and small detection volume (∼1 μL). A microfluidic channel is built directly above unpackaged p-i-n photodiodes to detect β-particles with maximum efficiency. The device is embedded in a compact system comprising dedicated electronics, shielding, and pumping unit controlled by custom firmware to enable measurements next to small-animal scanners. Data corrections required to use the input function in pharmacokinetic models were established using calibrated solutions of the most common PET and SPECT radiotracers. Sensitivity, dead time, propagation delay, dispersion, background sensitivity, and the effect of sample temperature were characterized. The system was tested for pharmacokinetic studies in mice by quantifying myocardial perfusion and oxygen consumption with (11)C-acetate (PET) and by measuring the arterial input function using (99m)TcO4 (-) (SPECT). Sensitivity for PET isotopes reached 20%-47%, a 2- to 10-fold improvement relative to conventional catheter-based geometries. Furthermore, the system detected (99m)Tc-based SPECT tracers with an efficiency of 4%, an outcome not possible through a catheter. Correction for dead time was found to be unnecessary for small-animal experiments, whereas propagation delay and dispersion within the microfluidic channel were accurately corrected. Background activity and sample temperature were shown to have no influence on measurements. Finally, the system was successfully used in animal studies. A fully operational microfluidic blood-counting system for preclinical pharmacokinetic studies was developed. Microfluidics enabled reliable and high-efficiency measurement of the blood concentration of most common PET and SPECT radiotracers with high temporal resolution in small blood volume. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Scalar and tensor perturbations in loop quantum cosmology: high-order corrections
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Tao; Wang, Anzhong; Wu, Qiang
2015-10-01
Loop quantum cosmology (LQC) provides promising resolutions to the trans-Planckian issue and initial singularity arising in the inflationary models of general relativity. In general, due to different quantization approaches, LQC involves two types of quantum corrections, the holonomy and inverse-volume, to both of the cosmological background evolution and perturbations. In this paper, using the third-order uniform asymptotic approximations, we derive explicitly the observational quantities of the slow-roll inflation in the framework of LQC with these quantum corrections. We calculate the power spectra, spectral indices, and running of the spectral indices for both scalar and tensor perturbations, whereby the tensor-to-scalar ratiomore » is obtained. We expand all the observables at the time when the inflationary mode crosses the Hubble horizon. As the upper error bounds for the uniform asymptotic approximation at the third-order are ∼< 0.15%, these results represent the most accurate results obtained so far in the literature. It is also shown that with the inverse-volume corrections, both scalar and tensor spectra exhibit a deviation from the usual shape at large scales. Then, using the Planck, BAO and SN data we obtain new constraints on quantum gravitational effects from LQC corrections, and find that such effects could be within the detection of the forthcoming experiments.« less
Target coverage in image-guided stereotactic body radiotherapy of liver tumors.
Wunderink, Wouter; Méndez Romero, Alejandra; Vásquez Osorio, Eliana M; de Boer, Hans C J; Brandwijk, René P; Levendag, Peter C; Heijmen, Ben J M
2007-05-01
To determine the effect of image-guided procedures (with computed tomography [CT] and electronic portal images before each treatment fraction) on target coverage in stereotactic body radiotherapy for liver patients using a stereotactic body frame (SBF) and abdominal compression. CT guidance was used to correct for day-to-day variations in the tumor's mean position in the SBF. By retrospectively evaluating 57 treatment sessions, tumor coverage, as obtained with the clinically applied CT-guided protocol, was compared with that of alternative procedures. The internal target volume-plus (ITV(+)) was introduced to explicitly include uncertainties in tumor delineations resulting from CT-imaging artifacts caused by residual respiratory motion. Tumor coverage was defined as the volume overlap of the ITV(+), derived from a tumor delineated in a treatment CT scan, and the planning target volume. Patient stability in the SBF, after acquisition of the treatment CT scan, was evaluated by measuring the displacement of the bony anatomy in the electronic portal images relative to CT. Application of our clinical protocol (with setup corrections following from manual measurements of the distances between the contours of the planning target volume and the daily clinical target volume in three orthogonal planes, multiple two-dimensional) increased the frequency of nearly full (> or = 99%) ITV(+) coverage to 77% compared with 63% without setup correction. An automated three-dimensional method further improved the frequency to 96%. Patient displacements in the SBF were generally small (< or = 2 mm, 1 standard deviation), but large craniocaudal displacements (maximal 7.2 mm) were occasionally observed. Daily, CT-assisted patient setup may substantially improve tumor coverage, especially with the automated three-dimensional procedure. In the present treatment design, patient stability in the SBF should be verified with portal imaging.
Gritti, Fabrice; McDonald, Thomas; Gilar, Martin
2015-11-13
The impact of the column hardware volume (≃ 1.7 μL) on the optimum reduced plate heights of a series of short 2.1 mm × 50 mm columns (hold-up volume ≃ 80-90 μL) packed with 1.8 μm HSS-T3, 1.7 μm BEH-C18, 1.7 μm CSH-C18, 1.6 μm CORTECS-C18+, and 1.7 μm BEH-C4 particles was investigated. A rapid and non-invasive method based on the reduction of the system dispersion (to only 0.15 μL(2)) of an I-class Acquity system and on the corrected plate heights (for system dispersion) of five weakly retained n-alkanophenones in RPLC was proposed. Evidence for sample dispersion through the column hardware volume was also revealed from the experimental plot of the peak capacities for smooth linear gradients versus the corrected efficiency of a weakly retained alkanophenone (isocratic runs). The plot is built for a constant gradient steepness irrespective of the applied flow rates (0.01-0.30 mL/min) and column lengths (2, 3, 5, and 10 cm). The volume variance caused by column endfittings and frits was estimated in between 0.1 and 0.7 μL(2) depending on the applied flow rate. After correction for system and hardware dispersion, the minimum reduced plate heights of short (5 cm) and narrow-bore (2.1mm i.d.) beds packed with sub-2 μm fully and superficially porous particles were found close to 1.5 and 0.7, respectively, instead of the classical h values of 2.0 and 1.4 for the whole column assembly. Copyright © 2015 Elsevier B.V. All rights reserved.
40 CFR 80.1622 - Approval for small refiner and small volume refinery status.
Code of Federal Regulations, 2014 CFR
2014-07-01
... appropriate data to correct the record when the company submits its application. (ii) Foreign small refiners... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Approval for small refiner and small... Approval for small refiner and small volume refinery status. (a) Applications for small refiner or small...
Measurement of Crystalline Lens Volume During Accommodation in a Lens Stretcher
Marussich, Lauren; Manns, Fabrice; Nankivil, Derek; Maceo Heilman, Bianca; Yao, Yue; Arrieta-Quintero, Esdras; Ho, Arthur; Augusteyn, Robert; Parel, Jean-Marie
2015-01-01
Purpose To determine if the lens volume changes during accommodation. Methods The study used data acquired on 36 cynomolgus monkey lenses that were stretched in a stepwise fashion to simulate disaccommodation. At each step, stretching force and dioptric power were measured and a cross-sectional image of the lens was acquired using an optical coherence tomography system. Images were corrected for refractive distortions and lens volume was calculated assuming rotational symmetry. The average change in lens volume was calculated and the relation between volume change and power change, and between volume change and stretching force, were quantified. Linear regressions of volume-power and volume-force plots were calculated. Results The mean (±SD) volume in the unstretched (accommodated) state was 97 ± 8 mm3. On average, there was a small but statistically significant (P = 0.002) increase in measured lens volume with stretching. The mean change in lens volume was +0.8 ± 1.3 mm3. The mean volume-power and volume-load slopes were −0.018 ± 0.058 mm3/D and +0.16 ± 0.40 mm3/g. Conclusions Lens volume remains effectively constant during accommodation, with changes that are less than 1% on average. This result supports a hypothesis that the change in lens shape with accommodation is accompanied by a redistribution of tissue within the capsular bag without significant compression of the lens contents or fluid exchange through the capsule. PMID:26161985
ERIC Educational Resources Information Center
Correctional Education Association.
Authors and titles of the 15 papers in this volume are as follows: "A Follow-up Study of Vocational Education Graduates from the Ohio Central School System during Fiscal Year 1979" (Earl R. Schaeffer, Theodore P. Shannon); "Legal and Policy Dimensions of Functional Illiteracy among Post-Secondary Inmate Students" (Paul Moke, Jarrell Holloway);…
Thalamic Atrophy Contributes to Low Slow Wave Sleep in Neuromyelitis Optica Spectrum Disorder.
Su, Lei; Han, Yujuan; Xue, Rong; Wood, Kristofer; Shi, Fu-Dong; Liu, Yaou; Fu, Ying
2016-12-01
Slow wave sleep abnormality has been reported in neuromyelitis optica spectrum disorder (NMOSD), but mechanism for such abnormality is unknown. To determine the structural defects in the brain that account for the decrease of slow wave sleep in NMOSD patients. Thirty-three NMOSD patients and 18 matched healthy controls (HC) were enrolled. Polysomnography was used to monitor slow wave sleep and three-dimensional T1-weighted MRIs were obtained to assess the alterations of grey matter volume. The percentage of deep slow wave sleep decreased in 93% NMOSD patients. Compared to HC, a reduction of grey matter volume was found in the bilateral thalamus of patients with a lower percentage of slow wave sleep (FWE corrected at cluster-level, p < 0.05, cluster size > 400 voxels). Furthermore, the right thalamic fraction was positively correlated with the decrease in the percentage of slow wave sleep in NMOSD patients (p < 0.05, FDR corrected, cluster size > 200 voxels). Our study identified that thalamic atrophy is associated with the decrease of slow wave sleep in NMOSD patients. Further studies should evaluate whether neurotransmitters or hormones which stem from thalamus are involved in the decrease of slow wave sleep.
Serum vitamin D and hippocampal gray matter volume in schizophrenia.
Shivakumar, Venkataram; Kalmady, Sunil V; Amaresha, Anekal C; Jose, Dania; Narayanaswamy, Janardhanan C; Agarwal, Sri Mahavir; Joseph, Boban; Venkatasubramanian, Ganesan; Ravi, Vasanthapuram; Keshavan, Matcheri S; Gangadhar, Bangalore N
2015-08-30
Disparate lines of evidence including epidemiological and case-control studies have increasingly implicated vitamin D in the pathogenesis of schizophrenia. Vitamin D deficiency can lead to dysfunction of the hippocampus--a brain region hypothesized to be critically involved in schizophrenia. In this study, we examined for potential association between serum vitamin D level and hippocampal gray matter volume in antipsychotic-naïve or antipsychotic-free schizophrenia patients (n = 35). Serum vitamin D level was estimated using 25-OH vitamin D immunoassay. Optimized voxel-based morphometry was used to analyze 3-Tesla magnetic resonance imaging (MRI) (1-mm slice thickness). Ninety-seven percent of the schizophrenia patients (n = 34) had sub-optimal levels of serum vitamin D (83%, deficiency; 14%, insufficiency). A significant positive correlation was seen between vitamin D and regional gray matter volume in the right hippocampus after controlling for age, years of education and total intracranial volume (Montreal Neurological Institute (MNI) coordinates: x = 35, y = -18, z = -8; t = 4.34 pFWE(Corrected) = 0.018). These observations support a potential role of vitamin D deficiency in mediating hippocampal volume deficits, possibly through neurotrophic, neuroimmunomodulatory and glutamatergic effects. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Jongkreangkrai, C.; Vichianin, Y.; Tocharoenchai, C.; Arimura, H.; Alzheimer's Disease Neuroimaging Initiative
2016-03-01
Several studies have differentiated Alzheimer's disease (AD) using cerebral image features derived from MR brain images. In this study, we were interested in combining hippocampus and amygdala volumes and entorhinal cortex thickness to improve the performance of AD differentiation. Thus, our objective was to investigate the useful features obtained from MRI for classification of AD patients using support vector machine (SVM). T1-weighted MR brain images of 100 AD patients and 100 normal subjects were processed using FreeSurfer software to measure hippocampus and amygdala volumes and entorhinal cortex thicknesses in both brain hemispheres. Relative volumes of hippocampus and amygdala were calculated to correct variation in individual head size. SVM was employed with five combinations of features (H: hippocampus relative volumes, A: amygdala relative volumes, E: entorhinal cortex thicknesses, HA: hippocampus and amygdala relative volumes and ALL: all features). Receiver operating characteristic (ROC) analysis was used to evaluate the method. AUC values of five combinations were 0.8575 (H), 0.8374 (A), 0.8422 (E), 0.8631 (HA) and 0.8906 (ALL). Although “ALL” provided the highest AUC, there were no statistically significant differences among them except for “A” feature. Our results showed that all suggested features may be feasible for computer-aided classification of AD patients.
LANDSAT-D program. Volume 2: Ground segment
NASA Technical Reports Server (NTRS)
1984-01-01
Raw digital data, as received from the LANDSAT spacecraft, cannot generate images that meet specifications. Radiometric corrections must be made to compensate for aging and for differences in sensitivity among the instrument sensors. Geometric corrections must be made to compensate for off-nadir look angle, and to calculate spacecraft drift from its prescribed path. Corrections must also be made for look-angle jitter caused by vibrations induced by spacecraft equipment. The major components of the LANDSAT ground segment and their functions are discussed.
NASA Technical Reports Server (NTRS)
Zwally, H. Jay; Brenner, Anita C.; Major, Judith A.; Martin, Thomas V.; Bindschadler, Robert A.
1990-01-01
The data-processing methods and ice data products derived from Seasat radar altimeter measurements over the Greenland ice sheet and surrounding sea ice are documented. The corrections derived and applied to the Seasat radar altimeter data over ice are described in detail, including the editing and retracking algorithm to correct for height errors caused by lags in the automatic range tracking circuit. The methods for radial adjustment of the orbits and estimation of the slope-induced errors are given.
Code of Federal Regulations, 2013 CFR
2013-07-01
... as propane; (6) Hydrochloric acid and chlorine gas in excess of 77 parts per million by volume, combined emissions, expressed as hydrochloric acid equivalents, dry basis and corrected to 7 percent oxygen... basis, corrected to 7 percent oxygen, and reported as propane; (6) Hydrochloric acid and chlorine gas in...
Code of Federal Regulations, 2014 CFR
2014-07-01
... as propane; (6) Hydrochloric acid and chlorine gas in excess of 77 parts per million by volume, combined emissions, expressed as hydrochloric acid equivalents, dry basis and corrected to 7 percent oxygen... basis, corrected to 7 percent oxygen, and reported as propane; (6) Hydrochloric acid and chlorine gas in...
Methods for the correction of vascular artifacts in PET O-15 water brain-mapping studies
NASA Astrophysics Data System (ADS)
Chen, Kewei; Reiman, E. M.; Lawson, M.; Yun, Lang-sheng; Bandy, D.; Palant, A.
1996-12-01
While positron emission tomographic (PET) measurements of regional cerebral blood flow (rCBF) can be used to map brain regions that are involved in normal and pathological human behaviors, measurements in the anteromedial temporal lobe can be confounded by the combined effects of radiotracer activity in neighboring arteries and partial-volume averaging. The authors now describe two simple methods to address this vascular artifact. One method utilizes the early frames of a dynamic PET study, while the other method utilizes a coregistered magnetic resonance image (MRI) to characterize the vascular region of interest (VROI). Both methods subsequently assign a common value to each pixel in the VROI for the control (baseline) scan and the activation scan. To study the vascular artifact and to demonstrate the ability of the proposed methods correcting the vascular artifact, four dynamic PET scans were performed in a single subject during the same behavioral state. For each of the four scans, a vascular scan containing vascular activity was computed as the summation of the images acquired 0-60 s after radiotracer administration, and a control scan containing minimal vascular activity was computed as the summation of the images acquired 20-80 s after radiotracer administration. t-score maps calculated from the four pairs of vascular and control scans were used to characterize regional blood flow differences related to vascular activity before and after the application of each vascular artifact correction method. Both methods eliminated the observed differences in vascular activity, as well as the vascular artifact observed in the anteromedial temporal lobes. Using PET data from a study of normal human emotion, these methods permitted the authors to identify rCBF increases in the anteromedial temporal lobe free from the potentially confounding, combined effects of vascular activity and partial-volume averaging.
Hsu, Shu-Hui; Cao, Yue; Lawrence, Theodore S.; Tsien, Christina; Feng, Mary; Grodzki, David M.; Balter, James M.
2015-01-01
Accurate separation of air and bone is critical for creating synthetic CT from MRI to support Radiation Oncology workflow. This study compares two different ultrashort echo-time sequences in the separation of air from bone, and evaluates post-processing methods that correct intensity nonuniformity of images and account for intensity gradients at tissue boundaries to improve this discriminatory power. CT and MRI scans were acquired on 12 patients under an institution review board-approved prospective protocol. The two MRI sequences tested were ultra-short TE imaging using 3D radial acquisition (UTE), and using pointwise encoding time reduction with radial acquisition (PETRA). Gradient nonlinearity correction was applied to both MR image volumes after acquisition. MRI intensity nonuniformity was corrected by vendor-provided normalization methods, and then further corrected using the N4itk algorithm. To overcome the intensity-gradient at air-tissue boundaries, spatial dilations, from 0 to 4 mm, were applied to threshold-defined air regions from MR images. Receiver operating characteristic (ROC) analyses, by comparing predicted (defined by MR images) versus “true” regions of air and bone (defined by CT images), were performed with and without residual bias field correction and local spatial expansion. The post-processing corrections increased the areas under the ROC curves (AUC) from 0.944 ± 0.012 to 0.976 ± 0.003 for UTE images, and from 0.850 ± 0.022 to 0.887 ± 0.012 for PETRA images, compared to without corrections. When expanding the threshold-defined air volumes, as expected, sensitivity of air identification decreased with an increase in specificity of bone discrimination, but in a non-linear fashion. A 1-mm air mask expansion yielded AUC increases of 1% and 4% for UTE and PETRA images, respectively. UTE images had significantly greater discriminatory power in separating air from bone than PETRA images. Post-processing strategies improved the discriminatory power of air from bone for both UTE and PETRA images, and reduced the difference between the two imaging sequences. Both postprocessed UTE and PETRA images demonstrated sufficient power to discriminate air from bone to support synthetic CT generation from MRI data. PMID:25776205
Association of Alzheimer's disease GWAS loci with MRI markers of brain aging.
Chauhan, Ganesh; Adams, Hieab H H; Bis, Joshua C; Weinstein, Galit; Yu, Lei; Töglhofer, Anna Maria; Smith, Albert Vernon; van der Lee, Sven J; Gottesman, Rebecca F; Thomson, Russell; Wang, Jing; Yang, Qiong; Niessen, Wiro J; Lopez, Oscar L; Becker, James T; Phan, Thanh G; Beare, Richard J; Arfanakis, Konstantinos; Fleischman, Debra; Vernooij, Meike W; Mazoyer, Bernard; Schmidt, Helena; Srikanth, Velandai; Knopman, David S; Jack, Clifford R; Amouyel, Philippe; Hofman, Albert; DeCarli, Charles; Tzourio, Christophe; van Duijn, Cornelia M; Bennett, David A; Schmidt, Reinhold; Longstreth, William T; Mosley, Thomas H; Fornage, Myriam; Launer, Lenore J; Seshadri, Sudha; Ikram, M Arfan; Debette, Stephanie
2015-04-01
Whether novel risk variants of Alzheimer's disease (AD) identified through genome-wide association studies also influence magnetic resonance imaging-based intermediate phenotypes of AD in the general population is unclear. We studied association of 24 AD risk loci with intracranial volume, total brain volume, hippocampal volume (HV), white matter hyperintensity burden, and brain infarcts in a meta-analysis of genetic association studies from large population-based samples (N = 8175-11,550). In single-SNP based tests, AD risk allele of APOE (rs2075650) was associated with smaller HV (p = 0.0054) and CD33 (rs3865444) with smaller intracranial volume (p = 0.0058). In gene-based tests, there was associations of HLA-DRB1 with total brain volume (p = 0.0006) and BIN1 with HV (p = 0.00089). A weighted AD genetic risk score was associated with smaller HV (beta ± SE = -0.047 ± 0.013, p = 0.00041), even after excluding the APOE locus (p = 0.029). However, only association of AD genetic risk score with HV, including APOE, was significant after multiple testing correction (including number of independent phenotypes tested). These results suggest that novel AD genetic risk variants may contribute to structural brain aging in nondemented older community persons. Copyright © 2015 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murthy, Vedang, E-mail: vmurthy@actrec.gov.in; Shukla, Pragya; Adurkar, Pranjal
2012-09-01
Purpose: To evaluate whether information from the initial fractions can determine which patients are likely to consistently exceed their planning dose-volume constraints during the course of radiotherapy for prostate cancer. Methods and Materials: Ten patients with high-risk prostate cancer were treated with helical tomotherapy to a dose of 60 Gy in 20 fractions. The prostate, rectum, and bladder were recontoured on their daily megavoltage computed tomography scans and the dose was recalculated. The bladder and rectal volumes (in mL) receiving {>=}100% and {>=}70% of the prescribed dose in each fraction and in the original plans were recorded. A fraction formore » which the difference between planned and delivered was more than 2 mL was considered a volume failure. Similarly if the difference in the planned and delivered maximum dose (D{sub max}) was {>=}1% for the rectum and bladder, the fraction was considered a dose failure. Each patient's first 3 to 5 fractions were analyzed to determine if they correctly identified those patients who would consistently fail (i.e., {>=}20% of fractions) during the course of their radiotherapy. Results: Six parameters were studied; the rectal volume (RV) and bladder volumes (BV) (in mL) received {>=}100% and {>=}70% of the prescribed dose and maximum dose to 2 mL of the rectum and bladder. This was given by RV{sub 100}, RV{sub 70}, BV{sub 100}, BV{sub 70}, RD{sub max}, and BD{sub max}, respectively. When more than 1 of the first 3 fractions exceed the planning constraint as defined, it accurately predicts consistent failures through the course of the treatment. This method is able to correctly identify the consistent failures about 80% (RV{sub 70}, BV{sub 100}, and RV{sub 100}), 90% (BV{sub 70}), and 100% (RD{sub max} and BD{sub max}) of the times. Conclusions: This study demonstrates the feasibility of a method accurately identifying patients who are likely to consistently exceed the planning constraints during the course of their treatment, using information from the first 3 to 5 fractions.« less
Mitral regurgitation: anatomy is destiny.
Athanasuleas, Constantine L; Stanley, Alfred W H; Buckberg, Gerald D
2018-04-26
Mitral regurgitation (MR) occurs when any of the valve and ventricular mitral apparatus components are disturbed. As MR progresses, left ventricular remodelling occurs, ultimately causing heart failure when the enlarging left ventricle (LV) loses its conical shape and becomes globular. Heart failure and lethal ventricular arrhythmias may develop if the left ventricular end-systolic volume index exceeds 55 ml/m2. These adverse changes persist despite satisfactory correction of the annular component of MR. Our goal was to describe this process and summarize evolving interventions that reduce the volume of the left ventricle and rebuild its elliptical shape. This 'valve/ventricle' approach addresses the spherical ventricular culprit and offsets the limits of treating MR by correcting only its annular component.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stoiber, Eva Maria, E-mail: eva.stoiber@med.uni-heidelberg.de; Department of Medical Physics, German Cancer Research Center, Heidelberg; Giske, Kristina
Purpose: To evaluate local positioning errors of the lumbar spine during fractionated intensity-modulated radiotherapy of patients treated with craniospinal irradiation and to assess the impact of rotational error correction on these uncertainties for one patient setup correction strategy. Methods and Materials: 8 patients (6 adults, 2 children) treated with helical tomotherapy for craniospinal irradiation were retrospectively chosen for this analysis. Patients were immobilized with a deep-drawn Aquaplast head mask. Additionally to daily megavoltage control computed tomography scans of the skull, once-a-week positioning of the lumbar spine was assessed. Therefore, patient setup was corrected by a target point correction, derived frommore » a registration of the patient's skull. The residual positioning variations of the lumbar spine were evaluated applying a rigid-registration algorithm. The impact of different rotational error corrections was simulated. Results: After target point correction, residual local positioning errors of the lumbar spine varied considerably. Craniocaudal axis rotational error correction did not improve or deteriorate these translational errors, whereas simulation of a rotational error correction of the right-left and anterior-posterior axis increased these errors by a factor of 2 to 3. Conclusion: The patient fixation used allows for deformations between the patient's skull and spine. Therefore, for the setup correction strategy evaluated in this study, generous margins for the lumbar spinal target volume are needed to prevent a local geographic miss. With any applied correction strategy, it needs to be evaluated whether or not a rotational error correction is beneficial.« less
Carotid Flow Time Test Performance for the Detection of Dehydration in Children With Diarrhea.
Mackenzie, David C; Nasrin, Sabiha; Atika, Bita; Modi, Payal; Alam, Nur H; Levine, Adam C
2018-06-01
Unstructured clinical assessments of dehydration in children are inaccurate. Point-of-care ultrasound is a noninvasive diagnostic tool that can help evaluate the volume status; the corrected carotid artery flow time has been shown to predict volume depletion in adults. We sought to determine the ability of the corrected carotid artery flow time to identify dehydration in a population of children presenting with acute diarrhea in Dhaka, Bangladesh. Children presenting with acute diarrhea were recruited and rehydrated according to hospital protocols. The corrected carotid artery flow time was measured at the time of presentation. The percentage of weight change with rehydration was used to categorize each child's dehydration as severe (>9%), some (3%-9%), or none (<3%). A receiver operating characteristic curve was constructed to test the performance of the corrected carotid artery flow time for detecting severe dehydration. Linear regression was used to model the relationship between the corrected carotid artery flow time and percentage of dehydration. A total of 350 children (0-60 months) were enrolled. The mean corrected carotid artery flow time was 326 milliseconds (interquartile range, 295-351 milliseconds). The area under the receiver operating characteristic curve for the detection of severe dehydration was 0.51 (95% confidence interval, 0.42, 0.61). Linear regression modeling showed a weak association between the flow time and dehydration. The corrected carotid artery flow time was a poor predictor of severe dehydration in this population of children with diarrhea. © 2017 by the American Institute of Ultrasound in Medicine.
LLCEDATA and LLCECALC for Windows version 1.0, Volume 3: Software verification and validation
DOE Office of Scientific and Technical Information (OSTI.GOV)
McFadden, J.G.
1998-09-04
LLCEDATA and LLCECALC for Windows are user-friendly computer software programs that work together to determine the proper waste designation, handling, and disposition requirements for Long Length Contaminated Equipment (LLCE). LLCEDATA reads from a variety of data bases to produce an equipment data file(EDF) that represents a snapshot of both the LLCE and the tank from which it originates. LLCECALC reads the EDF and the gamma assay file (AV2) that is produced by the flexible Receiver Gamma Energy Analysis System. LLCECALC performs corrections to the AV2 file as it is being read and characterizes the LLCE. Both programs produce a varietymore » of reports, including a characterization report and a status report. The status report documents each action taken by the user, LLCEDATA, and LLCECALC. Documentation for LLCEDATA and LLCECALC for Windows is available in three volumes. Volume 1 is a user`s manual, which is intended as a quick reference for both LLCEDATA and LLCECALC. Volume 2 is a technical manual, which discusses system limitations and provides recommendations to the LLCE process. Volume 3 documents LLCEDATA and LLCECALC`s verification and validation. Two of the three installation test cases, from Volume 1, are independently confirmed. Data bases used in LLCEDATA are verified and referenced. Both phases of LLCECALC process gamma and characterization, are extensively tested to verify that the methodology and algorithms used are correct.« less
Gilbert, Andrew R.; Keshavan, Matcheri S.; Diwadkar, Vaibhav; Nutche, Jeffrey; MacMaster, Frank; Easter, Phillip C.; Buhagiar, Christian J.; Rosenberg, David R.
2008-01-01
Neuroimaging studies have identified alterations in frontostriatal circuitry in OCD. Voxel-based morphometry (VBM) allows for the assessment of differences in gray matter density across the whole brain. VBM has not previously been used to examine regional gray matter density in pediatric OCD patients and the siblings of pediatric OCD patients. Volumetric magnetic resonance imaging (MRI) studies were conducted in 10 psychotropic-naïve pediatric patients with OCD, 10 unaffected siblings of pediatric patients with OCD, and 10 healthy controls. VBM analysis was conducted using SPM2. Statistical comparisons were performed with the general linear model, implementing small volume random field corrections for a priori regions of interest (anterior cingulate cortex or ACC, striatum and thalamus). VBM analysis revealed significantly lower gray matter density in OCD patients compared to healthy in the left ACC and bilateral medial superior frontal gyrus (SFG). Furthermore, a small volume correction was used to identify a significantly greater gray matter density in the right putamen in OCD patients as compared to unaffected siblings of OCD patients. These findings in patients, siblings, and healthy controls, although preliminary, suggest the presence of gray matter structural differences between affected subjects and healthy controls as well as between affected subjects and individuals at risk for OCD. PMID:18314272
DOE Office of Scientific and Technical Information (OSTI.GOV)
Staring, M., E-mail: m.staring@lumc.nl; Bakker, M. E.; Shamonin, D. P.
Purpose: Whole lung densitometry on chest CT images is an accepted method for measuring tissue destruction in patients with pulmonary emphysema in clinical trials. Progression measurement is required for evaluation of change in health condition and the effect of drug treatment. Information about the location of emphysema progression within the lung may be important for the correct interpretation of drug efficacy, or for determining a treatment plan. The purpose of this study is therefore to develop and validate methods that enable the local measurement of lung density changes, which requires proper modeling of the effect of respiration on density. Methods:more » Four methods, all based on registration of baseline and follow-up chest CT scans, are compared. The first naïve method subtracts registered images. The second employs the so-called dry sponge model, where volume correction is performed using the determinant of the Jacobian of the transformation. The third and the fourth introduce a novel adaptation of the dry sponge model that circumvents its constant-mass assumption, which is shown to be invalid. The latter two methods require a third CT scan at a different inspiration level to estimate the patient-specific density-volume slope, where one method employs a global and the other a local slope. The methods were validated on CT scans of a phantom mimicking the lung, where mass and volume could be controlled. In addition, validation was performed on data of 21 patients with pulmonary emphysema. Results: The image registration method was optimized leaving a registration error below half the slice increment (median 1.0 mm). The phantom study showed that the locally adapted slope model most accurately measured local progression. The systematic error in estimating progression, as measured on the phantom data, was below 2 gr/l for a 70 ml (6%) volume difference, and 5 gr/l for a 210 ml (19%) difference, if volume correction was applied. On the patient data an underlying linearity assumption relating lung volume change with density change was shown to hold (fitR{sup 2} = 0.94), and globalized versions of the local models are consistent with global results (R{sup 2} of 0.865 and 0.882 for the two adapted slope models, respectively). Conclusions: In conclusion, image matching and subsequent analysis of differences according to the proposed lung models (i) has good local registration accuracy on patient data, (ii) effectively eliminates a dependency on inspiration level at acquisition time, (iii) accurately predicts progression in phantom data, and (iv) is reasonably consistent with global results in patient data. It is therefore a potential future tool for assessing local emphysema progression in drug evaluation trials and in clinical practice.« less
Towards local progression estimation of pulmonary emphysema using CT.
Staring, M; Bakker, M E; Stolk, J; Shamonin, D P; Reiber, J H C; Stoel, B C
2014-02-01
Whole lung densitometry on chest CT images is an accepted method for measuring tissue destruction in patients with pulmonary emphysema in clinical trials. Progression measurement is required for evaluation of change in health condition and the effect of drug treatment. Information about the location of emphysema progression within the lung may be important for the correct interpretation of drug efficacy, or for determining a treatment plan. The purpose of this study is therefore to develop and validate methods that enable the local measurement of lung density changes, which requires proper modeling of the effect of respiration on density. Four methods, all based on registration of baseline and follow-up chest CT scans, are compared. The first naïve method subtracts registered images. The second employs the so-called dry sponge model, where volume correction is performed using the determinant of the Jacobian of the transformation. The third and the fourth introduce a novel adaptation of the dry sponge model that circumvents its constant-mass assumption, which is shown to be invalid. The latter two methods require a third CT scan at a different inspiration level to estimate the patient-specific density-volume slope, where one method employs a global and the other a local slope. The methods were validated on CT scans of a phantom mimicking the lung, where mass and volume could be controlled. In addition, validation was performed on data of 21 patients with pulmonary emphysema. The image registration method was optimized leaving a registration error below half the slice increment (median 1.0 mm). The phantom study showed that the locally adapted slope model most accurately measured local progression. The systematic error in estimating progression, as measured on the phantom data, was below 2 gr/l for a 70 ml (6%) volume difference, and 5 gr/l for a 210 ml (19%) difference, if volume correction was applied. On the patient data an underlying linearity assumption relating lung volume change with density change was shown to hold (fitR(2) = 0.94), and globalized versions of the local models are consistent with global results (R(2) of 0.865 and 0.882 for the two adapted slope models, respectively). In conclusion, image matching and subsequent analysis of differences according to the proposed lung models (i) has good local registration accuracy on patient data, (ii) effectively eliminates a dependency on inspiration level at acquisition time, (iii) accurately predicts progression in phantom data, and (iv) is reasonably consistent with global results in patient data. It is therefore a potential future tool for assessing local emphysema progression in drug evaluation trials and in clinical practice.
NASA Technical Reports Server (NTRS)
Hooker, Stanford B. (Editor); Firestone, Elaine R. (Editor); Mcclain, Charles R.; Comiso, Josefino C.; Fraser, Robert S.; Firestone, James K.; Schieber, Brian D.; Yeh, Eueng-Nan; Arrigo, Kevin R.; Sullivan, Cornelius W.
1994-01-01
Although the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Calibration and Validation Program relies on the scientific community for the collection of bio-optical and atmospheric correction data as well as for algorithm development, it does have the responsibility for evaluating and comparing the algorithms and for ensuring that the algorithms are properly implemented within the SeaWiFS Data Processing System. This report consists of a series of sensitivity and algorithm (bio-optical, atmospheric correction, and quality control) studies based on Coastal Zone Color Scanner (CZCS) and historical ancillary data undertaken to assist in the development of SeaWiFS specific applications needed for the proper execution of that responsibility. The topics presented are as follows: (1) CZCS bio-optical algorithm comparison, (2) SeaWiFS ozone data analysis study, (3) SeaWiFS pressure and oxygen absorption study, (4) pixel-by-pixel pressure and ozone correction study for ocean color imagery, (5) CZCS overlapping scenes study, (6) a comparison of CZCS and in situ pigment concentrations in the Southern Ocean, (7) the generation of ancillary data climatologies, (8) CZCS sensor ringing mask comparison, and (9) sun glint flag sensitivity study.
Seok, Ji-Woo; Sohn, Jin-Hun
2018-01-01
Neuroimaging studies on the characteristics of individuals with Internet gaming disorder (IGD) have been accumulating due to growing concerns regarding the psychological and social problems associated with Internet use. However, relatively little is known about the brain characteristics underlying IGD, such as the associated functional connectivity and structure. The aim of this study was to investigate alterations in gray matter (GM) volume and functional connectivity during resting state in individuals with IGD using voxel-based morphometry and a resting-state connectivity analysis. The participants included 20 individuals with IGD and 20 age- and sex-matched healthy controls. Resting-state functional and structural images were acquired for all participants using 3 T magnetic resonance imaging. We also measured the severity of IGD and impulsivity using psychological scales. The results show that IGD severity was positively correlated with GM volume in the left caudate (p < 0.05, corrected for multiple comparisons), and negatively associated with functional connectivity between the left caudate and the right middle frontal gyrus (p < 0.05, corrected for multiple comparisons). This study demonstrates that IGD is associated with neuroanatomical changes in the right middle frontal cortex and the left caudate. These are important brain regions for reward and cognitive control processes, and structural and functional abnormalities in these regions have been reported for other addictions, such as substance abuse and pathological gambling. The findings suggest that structural deficits and resting-state functional impairments in the frontostriatal network may be associated with IGD and provide new insights into the underlying neural mechanisms of IGD. PMID:29636704
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kicker, Dwayne Curtis; Herrick, Courtney G; Zeitler, Todd
2015-11-01
The numerical code DRSPALL (from direct release spallings) is written to calculate the volume of Waste Isolation Pilot Plant solid waste subject to material failure and transport to the surface (i.e., spallings) as a result of a hypothetical future inadvertent drilling intrusion into the repository. An error in the implementation of the DRSPALL finite difference equations was discovered and documented in a software problem report in accordance with the quality assurance procedure for software requirements. This paper describes the corrections to DRSPALL and documents the impact of the new spallings data from the modified DRSPALL on previous performance assessment calculations.more » Updated performance assessments result in more simulations with spallings, which generally translates to an increase in spallings releases to the accessible environment. Total normalized radionuclide releases using the modified DRSPALL data were determined by forming the summation of releases across each potential release pathway, namely borehole cuttings and cavings releases, spallings releases, direct brine releases, and transport releases. Because spallings releases are not a major contributor to the total releases, the updated performance assessment calculations of overall mean complementary cumulative distribution functions for total releases are virtually unchanged. Therefore, the corrections to the spallings volume calculation did not impact Waste Isolation Pilot Plant performance assessment calculation results.« less
[Bellows or bag? Testing 10 ventilators and some medical history comments].
Kötter, K P; Maleck, W H; Altmannsberger, S; Herchet, J; Petroianu, G A
1998-01-01
We compared a new bellows ventilator (Kendall Cardiovent) with two other bellows (Dräger Resutator 63, Tagg Breathsaver) and seven bag or ball ventilators (Aerodyne Hope, Ambu Mark 3, Ambu Silicon, Dräger Resutator 2000, Laerdal Resu, Mercury CPR, Weinmann Combibag). Tidal volumes were measured with two Laerdal Recording Resusci Annies, one lying on the floor, one in a bed. Twelve participants performed mask ventilation with all ten devices on both manikins for two minutes, trying to achieve tidal volumes of between 0.8 and 1.21 as recommended by the AHA. The last ten ventilations each on the graphic strips were analysed for volume. The participants scored handling of the devices on a 6-point scale (1 = very good, 6 = insufficient). The results of the Cardiovent were compared to those of the other devices by rank sum test (percentage of correct ventilations) and sign test (subjective handling). The Cardiovent provided exact ventilation with 95% of ventilations) on the floor and 78% of ventilations in bed in the recommended range. However, the percentage of correct ventilations with the Cardiovent was not significantly different to the other devices except for a lower percentage of correct ventilations with the Combibag in the in bed setting. Concerning subjective handling, the Cardiovent was significantly superior to several ball ventilators.
Chen, Hua-Hsuan; Rosenberg, David R; MacMaster, Frank P; Easter, Philip C; Caetano, Sheila C; Nicoletti, Mark; Hatch, John P; Nery, Fabiano G; Soares, Jair C
2008-12-01
Adults with major depressive disorder (MDD) are reported to have reduced orbitofrontal cortex (OFC) volumes, which could be related to decreased neuronal density. We conducted a study on medication naïve children with MDD to determine whether abnormalities of OFC are present early in the illness course. Twenty seven medication naïve pediatric Diagnostic and Statistical Manual of Mental Disorders, 4(th) edition (DSM-IV) MDD patients (mean age +/- SD = 14.4 +/- 2.2 years; 10 males) and 26 healthy controls (mean age +/- SD = 14.4 +/- 2.4 years; 12 males) underwent a 1.5T magnetic resonance imaging (MRI) with 3D spoiled gradient recalled acquisition. The OFC volumes were compared using analysis of covariance with age, gender, and total brain volume as covariates. There was no significant difference in either total OFC volume or total gray matter OFC volume between MDD patients and healthy controls. Exploratory analysis revealed that patients had unexpectedly larger total right lateral (F = 4.2, df = 1, 48, p = 0.05) and right lateral gray matter (F = 4.6, df = 1, 48, p = 0.04) OFC volumes compared to healthy controls, but this finding was not significant following statistical correction for multiple comparisons. No other OFC subregions showed a significant difference. The lack of OFC volume abnormalities in pediatric MDD patients suggests the abnormalities previously reported for adults may develop later in life as a result of neural cell loss.
Leu, Kevin; Boxerman, Jerrold L; Lai, Albert; Nghiemphu, Phioanh L; Pope, Whitney B; Cloughesy, Timothy F; Ellingson, Benjamin M
2016-11-01
To evaluate a leakage correction algorithm for T 1 and T2* artifacts arising from contrast agent extravasation in dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) that accounts for bidirectional contrast agent flux and compare relative cerebral blood volume (CBV) estimates and overall survival (OS) stratification from this model to those made with the unidirectional and uncorrected models in patients with recurrent glioblastoma (GBM). We determined median rCBV within contrast-enhancing tumor before and after bevacizumab treatment in patients (75 scans on 1.5T, 19 scans on 3.0T) with recurrent GBM without leakage correction and with application of the unidirectional and bidirectional leakage correction algorithms to determine whether rCBV stratifies OS. Decreased post-bevacizumab rCBV from baseline using the bidirectional leakage correction algorithm significantly correlated with longer OS (Cox, P = 0.01), whereas rCBV change using the unidirectional model (P = 0.43) or the uncorrected rCBV values (P = 0.28) did not. Estimates of rCBV computed with the two leakage correction algorithms differed on average by 14.9%. Accounting for T 1 and T2* leakage contamination in DSC-MRI using a two-compartment, bidirectional rather than unidirectional exchange model might improve post-bevacizumab survival stratification in patients with recurrent GBM. J. Magn. Reson. Imaging 2016;44:1229-1237. © 2016 International Society for Magnetic Resonance in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bialas, A.; Czyz, W.; Zalewski, K.
The relation between Renyi entropies and moments of the Wigner function, representing the quantum mechanical description of the M-particle semi-inclusive distribution at freeze-out, is investigated. It is shown that in the limit of infinite volume of the system, the classical and quantum descriptions are equivalent. Finite volume corrections are derived and shown to be small for systems encountered in relativistic heavy ion collisions.
ERIC Educational Resources Information Center
Adamec, Ludwig W., Ed.
Combining the most important geographical data with historical, political, and cultural information, this work, one of six volumes designed as a tool of research and a general reference source, updates and includes a previous publication compiled in 1914 with corrections and additions of maps and considerable new material to take into account…
Code of Federal Regulations, 2013 CFR
2013-07-01
... as propane; (6) Hydrochloric acid and chlorine gas in excess of 600 parts per million by volume, combined emissions, expressed as hydrochloric acid equivalents, dry basis and corrected to 7 percent oxygen...) Hydrochloric acid and chlorine gas in excess of 600 parts per million by volume, combined emissions, expressed...
Code of Federal Regulations, 2014 CFR
2014-07-01
... as propane; (6) Hydrochloric acid and chlorine gas in excess of 600 parts per million by volume, combined emissions, expressed as hydrochloric acid equivalents, dry basis and corrected to 7 percent oxygen...) Hydrochloric acid and chlorine gas in excess of 600 parts per million by volume, combined emissions, expressed...
30 CFR 250.198 - Documents incorporated by reference.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Conditions, May 2007; incorporated by reference at § 250.901; (3) API Bulletin 2INT-EX, Interim Guidance for...; incorporated by reference at § 250.1202; (34) API MPMS, Chapter 11.1—Volume Correction Factors, Volume 1, Table...; (35) API MPMS, Chapter 11.2.2—Compressibility Factors for Hydrocarbons: 0.350-0.637 Relative Density...
30 CFR 250.198 - Documents incorporated by reference.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Conditions, May 2007; incorporated by reference at § 250.901; (3) API Bulletin 2INT-EX, Interim Guidance for...; incorporated by reference at § 250.1202; (34) API MPMS, Chapter 11.1—Volume Correction Factors, Volume 1, Table...; (35) API MPMS, Chapter 11.2.2—Compressibility Factors for Hydrocarbons: 0.350-0.637 Relative Density...
Clinically significant change in stroke volume in pulmonary hypertension.
van Wolferen, Serge A; van de Veerdonk, Marielle C; Mauritz, Gert-Jan; Jacobs, Wouter; Marcus, J Tim; Marques, Koen M J; Bronzwaer, Jean G F; Heymans, Martijn W; Boonstra, Anco; Postmus, Pieter E; Westerhof, Nico; Vonk Noordegraaf, Anton
2011-05-01
Stroke volume is probably the best hemodynamic parameter because it reflects therapeutic changes and contains prognostic information in pulmonary hypertension (PH). Stroke volume directly reflects right ventricular function in response to its load, without the correction of compensatory increased heart rate as is the case for cardiac output. For this reason, stroke volume, which can be measured noninvasively, is an important hemodynamic parameter to monitor during treatment. However, the extent of change in stroke volume that constitutes a clinically significant change is unknown. The aim of this study was to determine the minimal important difference (MID) in stroke volume in PH. One hundred eleven patients were evaluated at baseline and after 1 year of follow-up with a 6-min walk test (6MWT) and cardiac MRI. Using the anchor-based method with 6MWT as the anchor, and the distribution-based method, the MID of stroke volume change could be determined. After 1 year of treatment, there was, on average, a significant increase in stroke volume and 6MWT. The change in stroke volume was related to the change in 6MWT. Using the anchor-based method, an MID of 10 mL in stroke volume was calculated. The distribution-based method resulted in an MID of 8 to 12 mL. Both methods showed that a 10-mL change in stroke volume during follow-up should be considered as clinically relevant. This value can be used to interpret changes in stroke volume during clinical follow-up in PH.
Järvelä, K; Koskinen, M; Kaukinen, S; Kööbi, T
2001-04-01
To compare the effects of hypertonic (7.5%) saline (HS), normal (0.9%) saline (NS), and 6% hydroxyethyl starch (HES) on extracellular fluid volumes in the early postoperative period after cardiopulmonary bypass. A prospective, randomized, double-blind study. University teaching hospital. Forty-eight patients scheduled for elective coronary artery bypass graft surgery. Patients were randomly allocated to receive 4 mL/kg of HS, NS, or HES during 30 minutes when volume loading was needed during the postoperative rewarming period in the intensive care unit. Plasma volume was measured using a dilution of iodine-125-labeled human serum albumin. Extracellular water and cardiac output were measured by whole-body impedance cardiography. Plasma volume had increased by 19 +/- 7% in the HS group and by 10 +/- 3% in the NS group (p = 0.001) at the end of the study fluid infusion. After 1-hour follow-up time, the plasma volume increase was greatest (23 +/- 8%) in the group receiving HES (p < 0.001). The increase of extracellular water was greater than the infused volume in the HS and HES groups at the end of the infusion. One-hour diuresis after the study infusion was greater in the HS group (536 +/- 280 mL) than in the NS (267 +/- 154 mL, p = 0.006) and HES groups (311 +/- 238 mL, p = 0.025). The effect of HS on plasma volume was short-lasting, but it stimulated excretion of excess body fluid accumulated during cardiopulmonary bypass and cardiac surgery. HS may be used in situations in which excess free water administration is to be avoided but the intravascular volume needs correction. Copyright 2001 by W.B. Saunders Company
Analysis of excimer laser radiant exposure effect toward corneal ablation volume at LASIK procedure
NASA Astrophysics Data System (ADS)
Adiati, Rima Fitria; Rini Rizki, Artha Bona; Kusumawardhani, Apriani; Setijono, Heru; Rahmadiansah, Andi
2016-11-01
LASIK (Laser Asissted In Situ Interlamelar Keratomilieusis) is a technique for correcting refractive disorders of the eye such as myopia and astigmatism using an excimer laser. This procedure use photoablation technique to decompose corneal tissues. Although preferred due to its efficiency, permanency, and accuracy, the inappropriate amount radiant exposure often cause side effects like under-over correction, irregular astigmatism and problems on surrounding tissues. In this study, the radiant exposure effect toward corneal ablation volume has been modelled through several processes. Data collecting results is laser data specifications with 193 nm wavelength, beam diameter of 0.065 - 0.65 cm, and fluence of 160 mJ/cm2. For the medical data, the myopia-astigmatism value, cornea size, corneal ablation thickness, and flap data are taken. The first modelling step is determining the laser diameter between 0.065 - 0.65 cm with 0.45 cm increment. The energy, power, and intensity of laser determined from laser beam area. Number of pulse and total energy is calculated before the radiant exposure of laser is obtained. Next is to determine the parameters influence the ablation volume. Regression method used to create the equation, and then the spot size is substituted to the model. The validation used is statistic correlation method to both experimental data and theory. By the model created, it is expected that any potential complications can be prevented during LASIK procedures. The recommendations can give the users clearer picture to determine the appropriate amount of radiant exposure with the corneal ablation volume necessary.
Piper, Rory J; Yoong, Michael M; Pujar, Suresh; Chin, Richard F
2014-01-01
Background Correcting volumetric measurements of brain structures for intracranial volume (ICV) is important in comparing volumes across subjects with different ICV. The aim of this study was to investigate whether intracranial area (ICA) reliably predicts actual ICV in a healthy pediatric cohort and in children with convulsive status epilepticus (CSE). Methods T1-weighted volumetric MRI was performed on 20 healthy children (control group), 10 with CSE with structurally normal MRI (CSE/MR-), and 12 with CSE with structurally abnormal MRI (CSE/MR+). ICA, using a mid-sagittal slice, and the actual ICV were measured. Results A high Spearman correlation was found between the ICA and ICV measurements in the control (r = 0.96; P < 0.0001), CSE/MR− (r = 0.93; P = 0.0003), and CSE/MR+ (r = 0.94; P < 0.0001) groups. On comparison of predicted and actual ICV, there was no significant difference in the CSE/MR− group (P = 0.77). However, the comparison between predicted and actual ICV was significantly different in the CSE/MR+ (P = 0.001) group. Our Bland–Altman plot showed that the ICA method consistently overestimated ICV in children in the CSE/MR+ group, especially in those with small ICV or widespread structural abnormalities. Conclusions After further validation, ICA measurement may be a reliable alternative to measuring actual ICV when correcting volume measurements for ICV, even in children with localized MRI abnormalities. Caution should be applied when the method is used in children with small ICV and those with multilobar brain pathology. PMID:25365798
A multifractal approach to space-filling recovery for PET quantification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Willaime, Julien M. Y., E-mail: julien.willaime@siemens.com; Aboagye, Eric O.; Tsoumpas, Charalampos
2014-11-01
Purpose: A new image-based methodology is developed for estimating the apparent space-filling properties of an object of interest in PET imaging without need for a robust segmentation step and used to recover accurate estimates of total lesion activity (TLA). Methods: A multifractal approach and the fractal dimension are proposed to recover the apparent space-filling index of a lesion (tumor volume, TV) embedded in nonzero background. A practical implementation is proposed, and the index is subsequently used with mean standardized uptake value (SUV {sub mean}) to correct TLA estimates obtained from approximate lesion contours. The methodology is illustrated on fractal andmore » synthetic objects contaminated by partial volume effects (PVEs), validated on realistic {sup 18}F-fluorodeoxyglucose PET simulations and tested for its robustness using a clinical {sup 18}F-fluorothymidine PET test–retest dataset. Results: TLA estimates were stable for a range of resolutions typical in PET oncology (4–6 mm). By contrast, the space-filling index and intensity estimates were resolution dependent. TLA was generally recovered within 15% of ground truth on postfiltered PET images affected by PVEs. Volumes were recovered within 15% variability in the repeatability study. Results indicated that TLA is a more robust index than other traditional metrics such as SUV {sub mean} or TV measurements across imaging protocols. Conclusions: The fractal procedure reported here is proposed as a simple and effective computational alternative to existing methodologies which require the incorporation of image preprocessing steps (i.e., partial volume correction and automatic segmentation) prior to quantification.« less
NASA Technical Reports Server (NTRS)
Pueschel, R. F.; Overbeck, V. R.; Snetsinger, K. G.; Russell, P. B.; Ferry, G. V.
1990-01-01
The use of the active scattering spectrometer probe (ASAS-X) to measure sulfuric acid aerosols on U-2 and ER-2 research aircraft has yielded results that are at times ambiguous due to the dependence of particles' optical signatures on refractive index as well as physical dimensions. The calibration correction of the ASAS-X optical spectrometer probe for stratospheric aerosol studies is validated through an independent and simultaneous sampling of the particles with impactors; sizing and counting of particles on SEM images yields total particle areas and volumes. Upon correction of calibration in light of these data, spectrometer results averaged over four size distributions are found to agree with similarly averaged impactor results to within a few percent: indicating that the optical properties or chemical composition of the sample aerosol must be known in order to achieve accurate optical aerosol spectrometer size analysis.
1985-09-01
steadily developed along with the better understanding of human relations, moti- vation and worklife sciences. That this is so, is clear from a review of...accomplish its goals effectively and efficiently if it is not staffed with the correct number of people with the correct balance of education, training and
ERIC Educational Resources Information Center
Stenhjem, Pam
2006-01-01
This brief describes two exceptional model programs for adjudicated youth with disabilities: Woodland Hills Residential Facility in Duluth, Minnesota and the Minnesota Correctional Facility-Walter McGinnis High School in Red Wing, Minnesota. The brief shares best practices from research about these programs as well as insight, commentary, and…
Clinical evaluation of respiration-induced attenuation uncertainties in pulmonary 3D PET/CT.
Kruis, Matthijs F; van de Kamer, Jeroen B; Vogel, Wouter V; Belderbos, José Sa; Sonke, Jan-Jakob; van Herk, Marcel
2015-12-01
In contemporary positron emission tomography (PET)/computed tomography (CT) scanners, PET attenuation correction is performed by means of a CT-based attenuation map. Respiratory motion can however induce offsets between the PET and CT data. Studies have demonstrated that these offsets can cause errors in quantitative PET measures. The purpose of this study is to quantify the effects of respiration-induced CT differences on the attenuation correction of pulmonary 18-fluordeoxyglucose (FDG) 3D PET/CT in a patient population and to investigate contributing factors. For 32 lung cancer patients, 3D-CT, 4D-PET and 4D-CT data were acquired. The 4D FDG PET data were attenuation corrected (AC) using a free-breathing 3D-CT (3D-AC), the end-inspiration CT (EI-AC), the end-expiration CT (EE-AC) or phase-by-phase (P-AC). After reconstruction and AC, the 4D-PET data were averaged. In the 4Davg data, we measured maximum tumour standardised uptake value (SUV)max in the tumour, SUVmean in a lung volume of interest (VOI) and average SUV (SUVmean) in a muscle VOI. On the 4D-CT, we measured the lung volume differences and CT number changes between inhale and exhale in the lung VOI. Compared to P-AC, we found -2.3% (range -9.7% to 1.2%) lower tumour SUVmax in EI-AC and 2.0% (range -0.9% to 9.5%) higher SUVmax in EE-AC. No differences in the muscle SUV were found. The use of 3D-AC led to respiration-induced SUVmax differences up to 20% compared to the use of P-AC. SUVmean differences in the lung VOI between EI-AC and EE-AC correlated to average CT differences in this region (ρ = 0.83). SUVmax differences in the tumour correlated to the volume changes of the lungs (ρ = -0.55) and the motion amplitude of the tumour (ρ = 0.53), both as measured on the 4D-CT. Respiration-induced CT variations in clinical data can in extreme cases lead to SUV effects larger than 10% on PET attenuation correction. These differences were case specific and correlated to differences in CT number in the lungs.
Wegener, Sonja; Sauer, Otto A
2018-02-01
Different detector properties will heavily affect the results of off-axis measurements outside of radiation fields, where a different energy spectrum is encountered. While a diode detector would show a high spatial resolution, it contains high atomic number elements, which lead to perturbations and energy-dependent response. An ionization chamber, on the other hand, has a much smaller energy dependence, but shows dose averaging over its larger active volume. We suggest a way to obtain spatial energy response corrections of a detector independent of its volume effect for profiles of arbitrary fields by using a combination of two detectors. Measurements were performed at an Elekta Versa HD accelerator equipped with an Agility MLC. Dose profiles of fields between 10 × 4 cm² and 0.6 × 0.6 cm² were recorded several times, first with different small-field detectors (unshielded diode 60012 and stereotactic field detector SFD, microDiamond, EDGE, and PinPoint 31006) and then with a larger volume ionization chamber Semiflex 31010 for different photon beam qualities of 6, 10, and 18 MV. Correction factors for the small-field detectors were obtained from the readings of the respective detector and the ionization chamber using a convolution method. Selected profiles were also recorded on film to enable a comparison. After applying the correction factors to the profiles measured with different detectors, agreement between the detectors and with profiles measured on EBT3 film was improved considerably. Differences in the full width half maximum obtained with the detectors and the film typically decreased by a factor of two. Off-axis correction factors outside of a 10 × 1 cm² field ranged from about 1.3 for the EDGE diode about 10 mm from the field edge to 0.7 for the PinPoint 31006 25 mm from the field edge. The microDiamond required corrections comparable in size to the Si-diodes and even exceeded the values in the tail region of the field. The SFD was found to require the smallest correction. The corrections typically became larger for higher energies and for smaller field sizes. With a combination of two detectors, experimentally derived correction factors can be obtained. Application of those factors leads to improved agreement between the measured profiles and those recorded on EBT3 film. The results also complement so far only Monte Carlo-simulated values for the off-axis response of different detectors. © 2017 American Association of Physicists in Medicine.
Kuijpers, Laura Maria Francisca; Maltha, Jessica; Guiraud, Issa; Kaboré, Bérenger; Lompo, Palpouguini; Devlieger, Hugo; Van Geet, Chris; Tinto, Halidou; Jacobs, Jan
2016-06-02
Plasmodium falciparum infection may cause severe anaemia, particularly in children. When planning a diagnostic study on children suspected of severe malaria in sub-Saharan Africa, it was questioned how much blood could be safely sampled; intended blood volumes (blood cultures and EDTA blood) were 6 mL (children aged <6 years) and 10 mL (6-12 years). A previous review [Bull World Health Organ. 89: 46-53. 2011] recommended not to exceed 3.8 % of total blood volume (TBV). In a simulation exercise using data of children previously enrolled in a study about severe malaria and bacteraemia in Burkina Faso, the impact of this 3.8 % safety guideline was evaluated. For a total of 666 children aged >2 months to <12 years, data of age, weight and haemoglobin value (Hb) were available. For each child, the estimated TBV (TBVe) (mL) was calculated by multiplying the body weight (kg) by the factor 80 (ml/kg). Next, TBVe was corrected for the degree of anaemia to obtain the functional TBV (TBVf). The correction factor consisted of the rate 'Hb of the child divided by the reference Hb'; both the lowest ('best case') and highest ('worst case') reference Hb values were used. Next, the exact volume that a 3.8 % proportion of this TBVf would present was calculated and this volume was compared to the blood volumes that were intended to be sampled. When applied to the Burkina Faso cohort, the simulation exercise pointed out that in 5.3 % (best case) and 11.4 % (worst case) of children the blood volume intended to be sampled would exceed the volume as defined by the 3.8 % safety guideline. Highest proportions would be in the age groups 2-6 months (19.0 %; worst scenario) and 6 months-2 years (15.7 %; worst case scenario). A positive rapid diagnostic test for P. falciparum was associated with an increased risk of violating the safety guideline in the worst case scenario (p = 0.016). Blood sampling in children for research in P. falciparum endemic settings may easily violate the proposed safety guideline when applied to TBVf. Ethical committees and researchers should be wary of this and take appropriate precautions.
Riedel, Andreas; Maier, Simon; Ulbrich, Melanie; Biscaldi, Monica; Ebert, Dieter; Fangmeier, Thomas; Perlov, Evgeniy; Tebartz van Elst, Ludger
2014-08-30
Autism spectrum disorder (ASD) is increasingly being recognized as an important issue in adult psychiatry and psychotherapy. High intelligence indicates overall good brain functioning and might thus present a particularly good opportunity to study possible cerebral correlates of core autistic features in terms of impaired social cognition, communication skills, the need for routines, and circumscribed interests. Anatomical MRI data sets for 30 highly intelligent patients with high-functioning autism and 30 pairwise-matched control subjects were acquired and analyzed with voxel-based morphometry. The gray matter volume of the pairwise-matched patients and the controls did not differ significantly. When correcting for total brain volume influences, the patients with ASD exhibited smaller left superior frontal volumes on a trend level. Heterogeneous volumetric findings in earlier studies might partly be explained by study samples biased by a high inclusion rate of secondary forms of ASD, which often go along with neuronal abnormalities. Including only patients with high IQ scores might have decreased the influence of secondary forms of ASD and might explain the absence of significant volumetric differences between the patients and the controls in this study. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Monte Carlo calculated correction factors for diodes and ion chambers in small photon fields.
Czarnecki, D; Zink, K
2013-04-21
The application of small photon fields in modern radiotherapy requires the determination of total scatter factors Scp or field factors Ω(f(clin), f(msr))(Q(clin), Q(msr)) with high precision. Both quantities require the knowledge of the field-size-dependent and detector-dependent correction factor k(f(clin), f(msr))(Q(clin), Q(msr)). The aim of this study is the determination of the correction factor k(f(clin), f(msr))(Q(clin), Q(msr)) for different types of detectors in a clinical 6 MV photon beam of a Siemens KD linear accelerator. The EGSnrc Monte Carlo code was used to calculate the dose to water and the dose to different detectors to determine the field factor as well as the mentioned correction factor for different small square field sizes. Besides this, the mean water to air stopping power ratio as well as the ratio of the mean energy absorption coefficients for the relevant materials was calculated for different small field sizes. As the beam source, a Monte Carlo based model of a Siemens KD linear accelerator was used. The results show that in the case of ionization chambers the detector volume has the largest impact on the correction factor k(f(clin), f(msr))(Q(clin), Q(msr)); this perturbation may contribute up to 50% to the correction factor. Field-dependent changes in stopping-power ratios are negligible. The magnitude of k(f(clin), f(msr))(Q(clin), Q(msr)) is of the order of 1.2 at a field size of 1 × 1 cm(2) for the large volume ion chamber PTW31010 and is still in the range of 1.05-1.07 for the PinPoint chambers PTW31014 and PTW31016. For the diode detectors included in this study (PTW60016, PTW 60017), the correction factor deviates no more than 2% from unity in field sizes between 10 × 10 and 1 × 1 cm(2), but below this field size there is a steep decrease of k(f(clin), f(msr))(Q(clin), Q(msr)) below unity, i.e. a strong overestimation of dose. Besides the field size and detector dependence, the results reveal a clear dependence of the correction factor on the accelerator geometry for field sizes below 1 × 1 cm(2), i.e. on the beam spot size of the primary electrons hitting the target. This effect is especially pronounced for the ionization chambers. In conclusion, comparing all detectors, the unshielded diode PTW60017 is highly recommended for small field dosimetry, since its correction factor k(f(clin), f(msr))(Q(clin), Q(msr)) is closest to unity in small fields and mainly independent of the electron beam spot size.
Correction for slope in point and transect relascope sampling of downed coarse woody debris
Goran Stahl; Anna Ringvall; Jeffrey H. Gove; Mark J. Ducey
2002-01-01
In this article, the effect of sloping terrain on estimates in point and transect relascope sampling (PRS and TRS, respectively) is studied. With these inventory methods, a wide angle relascope is used either from sample points (PRS) or along survey lines (TRS). Characteristics associated with line-shaped objects on the ground are assessed, e.g., the length or volume...
Brain Volume Estimation Enhancement by Morphological Image Processing Tools.
Zeinali, R; Keshtkar, A; Zamani, A; Gharehaghaji, N
2017-12-01
Volume estimation of brain is important for many neurological applications. It is necessary in measuring brain growth and changes in brain in normal/abnormal patients. Thus, accurate brain volume measurement is very important. Magnetic resonance imaging (MRI) is the method of choice for volume quantification due to excellent levels of image resolution and between-tissue contrast. Stereology method is a good method for estimating volume but it requires to segment enough MRI slices and have a good resolution. In this study, it is desired to enhance stereology method for volume estimation of brain using less MRI slices with less resolution. In this study, a program for calculating volume using stereology method has been introduced. After morphologic method, dilation was applied and the stereology method enhanced. For the evaluation of this method, we used T1-wighted MR images from digital phantom in BrainWeb which had ground truth. The volume of 20 normal brain extracted from BrainWeb, was calculated. The volumes of white matter, gray matter and cerebrospinal fluid with given dimension were estimated correctly. Volume calculation from Stereology method in different cases was made. In three cases, Root Mean Square Error (RMSE) was measured. Case I with T=5, d=5, Case II with T=10, D=10 and Case III with T=20, d=20 (T=slice thickness, d=resolution as stereology parameters). By comparing these results of two methods, it is obvious that RMSE values for our proposed method are smaller than Stereology method. Using morphological operation, dilation allows to enhance the estimation volume method, Stereology. In the case with less MRI slices and less test points, this method works much better compared to Stereology method.
Ito, Hiroshi; Shinotoh, Hitoshi; Shimada, Hitoshi; Miyoshi, Michie; Yanai, Kazuhiko; Okamura, Nobuyuki; Takano, Harumasa; Takahashi, Hidehiko; Arakawa, Ryosuke; Kodaka, Fumitoshi; Ono, Maiko; Eguchi, Yoko; Higuchi, Makoto; Fukumura, Toshimitsu; Suhara, Tetsuya
2014-04-01
The characteristic neuropathological changes in Alzheimer's disease (AD) are deposition of amyloid senile plaques and neurofibrillary tangles. The (18)F-labeled amyloid tracer, [(18)F]2-[(2-{(E)-2-[2-(dimethylamino)-1,3-thiazol-5-yl]vinyl}-1,3-benzoxazol-6-yl)oxy]-3-fluoropropan-1-ol (FACT), one of the benzoxazole derivatives, was recently developed. In the present study, deposition of amyloid senile plaques was measured by positron emission tomography (PET) with both [(11)C]Pittsburgh compound B (PIB) and [(18)F]FACT in the same subjects, and the regional uptakes of both radiotracers were directly compared. Two PET scans, one of each with [(11)C]PIB and [(18)F]FACT, were performed sequentially on six normal control subjects, two mild cognitive impairment (MCI) patients, and six AD patients. The standardized uptake value ratio of brain regions to the cerebellum was calculated with partial volume correction using magnetic resonance (MR) images to remove the effects of white matter accumulation. No significant differences in the cerebral cortical uptake were observed between normal control subjects and AD patients in [(18)F]FACT studies without partial volume correction, while significant differences were observed in [(11)C]PIB. After partial volume correction, the cerebral cortical uptake was significantly larger in AD patients than in normal control subjects for [(18)F]FACT studies as well as [(11)C]PIB. Relatively lower uptakes of [(11)C]PIB in distribution were observed in the medial side of the temporal cortex and in the occipital cortex as compared with [(18)F]FACT. Relatively higher uptake of [(11)C]PIB in distribution was observed in the frontal and parietal cortices. Since [(18)F]FACT might bind more preferentially to dense-cored amyloid deposition, regional differences in cerebral cortical uptake between [(11)C]PIB and [(18)F]FACT might be due to differences in regional distribution between diffuse and dense-cored amyloid plaque shown in the autoradiographic and histochemical assays of postmortem AD brain sections.
Education, occupation, leisure activities, and brain reserve: a population-based study.
Foubert-Samier, Alexandra; Catheline, Gwenaelle; Amieva, Hélène; Dilharreguy, Bixente; Helmer, Catherine; Allard, Michèle; Dartigues, Jean-François
2012-02-01
The influence of education, occupation, and leisure activities on the passive and active components of reserve capacity remains unclear. We used the voxel-based morphometry (VBM) technique in a population-based sample of 331 nondemented people in order to investigate the relationship between these factors and the cerebral volume (a marker of brain reserve). The results showed a positive and significant association between education, occupation, and leisure activities and the cognitive performances on Isaac's set test. Among these factors, only education was significantly associated with a cerebral volume including gray and white matter (p = 0.01). In voxel-based morphometry analyses, the difference in gray matter volume was located in the temporoparietal lobes and in the orbitofrontal lobes bilaterally (a p-value corrected <0.05 by false discovery rate [FDR]). Although smaller, the education-related difference in white matter volume appeared in areas connected to the education-related difference in gray matter volume. Education, occupation attainment, and leisure activities were found to contribute differently to reserve capacity. Education could play a role in the constitution of cerebral reserve capacity. Copyright © 2012 Elsevier Inc. All rights reserved.
Component extraction on CT volumes of assembled products using geometric template matching
NASA Astrophysics Data System (ADS)
Muramatsu, Katsutoshi; Ohtake, Yutaka; Suzuki, Hiromasa; Nagai, Yukie
2017-03-01
As a method of non-destructive internal inspection, X-ray computed tomography (CT) is used not only in medical applications but also for product inspection. Some assembled products can be divided into separate components based on density, which is known to be approximately proportional to CT values. However, components whose densities are similar cannot be distinguished using the CT value driven approach. In this study, we proposed a new component extraction algorithm from the CT volume, using a set of voxels with an assigned CT value with the surface mesh as the template rather than the density. The method has two main stages: rough matching and fine matching. At the rough matching stage, the position of candidate targets is identified roughly from the CT volume, using the template of the target component. At the fine matching stage, these candidates are precisely matched with the templates, allowing the correct position of the components to be detected from the CT volume. The results of two computational experiments showed that the proposed algorithm is able to extract components with similar density within the assembled products on CT volumes.
Comparison of ring artifact removal methods using flat panel detector based CT images
2011-01-01
Background Ring artifacts are the concentric rings superimposed on the tomographic images often caused by the defective and insufficient calibrated detector elements as well as by the damaged scintillator crystals of the flat panel detector. It may be also generated by objects attenuating X-rays very differently in different projection direction. Ring artifact reduction techniques so far reported in the literature can be broadly classified into two groups. One category of the approaches is based on the sinogram processing also known as the pre-processing techniques and the other category of techniques perform processing on the 2-D reconstructed images, recognized as the post-processing techniques in the literature. The strength and weakness of these categories of approaches are yet to be explored from a common platform. Method In this paper, a comparative study of the two categories of ring artifact reduction techniques basically designed for the multi-slice CT instruments is presented from a common platform. For comparison, two representative algorithms from each of the two categories are selected from the published literature. A very recently reported state-of-the-art sinogram domain ring artifact correction method that classifies the ring artifacts according to their strength and then corrects the artifacts using class adaptive correction schemes is also included in this comparative study. The first sinogram domain correction method uses a wavelet based technique to detect the corrupted pixels and then using a simple linear interpolation technique estimates the responses of the bad pixels. The second sinogram based correction method performs all the filtering operations in the transform domain, i.e., in the wavelet and Fourier domain. On the other hand, the two post-processing based correction techniques actually operate on the polar transform domain of the reconstructed CT images. The first method extracts the ring artifact template vector using a homogeneity test and then corrects the CT images by subtracting the artifact template vector from the uncorrected images. The second post-processing based correction technique performs median and mean filtering on the reconstructed images to produce the corrected images. Results The performances of the comparing algorithms have been tested by using both quantitative and perceptual measures. For quantitative analysis, two different numerical performance indices are chosen. On the other hand, different types of artifact patterns, e.g., single/band ring, artifacts from defective and mis-calibrated detector elements, rings in highly structural object and also in hard object, rings from different flat-panel detectors are analyzed to perceptually investigate the strength and weakness of the five methods. An investigation has been also carried out to compare the efficacy of these algorithms in correcting the volume images from a cone beam CT with the parameters determined from one particular slice. Finally, the capability of each correction technique in retaining the image information (e.g., small object at the iso-center) accurately in the corrected CT image has been also tested. Conclusions The results show that the performances of the algorithms are limited and none is fully suitable for correcting different types of ring artifacts without introducing processing distortion to the image structure. To achieve the diagnostic quality of the corrected slices a combination of the two approaches (sinogram- and post-processing) can be used. Also the comparing methods are not suitable for correcting the volume images from a cone beam flat-panel detector based CT. PMID:21846411
Kim, Eun-Ju; Kim, Dae-Hong; Lee, Sang Hoon; Huh, Yong-Min; Song, Ho-Taek; Suh, Jin-Suck
2004-04-01
This study compared two methods, corrected (separation of T(1) and T(2)* effects) and uncorrected, in order to determine the suitability of the perfusion and permeability measures through Delta R(2)* and Delta R(1) analyses. A dynamic susceptibility contrast dual gradient echo (DSC-DGE) was used to image the fixed phantoms and flow phantoms (Sephadex perfusion phantoms and dialyzer phantom for the permeability measurements). The results confirmed that the corrected relaxation rate was linearly proportional to gadolinium-diethyltriamine pentaacetic acid (Gd-DTPA) concentration, whereas the uncorrected relaxation rate did not in the fixed phantom and simulation experiments. For the perfusion measurements, it was found that the correction process was necessary not only for the Delta R(1) time curve but also for the Delta R(2)* time curve analyses. Perfusion could not be measured without correcting the Delta R(2)* time curve. The water volume, which was expressed as the perfusion amount, was found to be closer to the theoretical value when using the corrected Delta R(1) curve in the calculations. However, this may occur in the low concentration of Gd-DTPA in tissue used in this study. For the permeability measurements based on the two-compartment model, the permeability factor (k(ev); e = extravascular, v = vascular) from the outside to the inside of the hollow fibers was greater in the corrected Delta R(1) method than in the uncorrected Delta R(1) method. The differences between the corrected and the uncorrected Delta R(1) values were confirmed by the simulation experiments. In conclusion, this study proposes that the correction for the relaxation rates, Delta R(2)* and Delta R(1), is indispensable in making accurate perfusion and permeability measurements, and that DSC-DGE is a useful method for obtaining information on perfusion and permeability, simultaneously.
NASA Astrophysics Data System (ADS)
Bijnens, Johan; Rössler, Thomas
2015-11-01
We present a calculation of the finite volume corrections to meson masses and decay constants in three flavour Partially Quenched Chiral Perturbation Theory (PQChPT) through two-loop order in the chiral expansion for the flavour-charged (or off-diagonal) pseudoscalar mesons. The analytical results are obtained for three sea quark flavours with one, two or three different masses. We reproduce the known infinite volume results and the finite volume results in the unquenched case. The calculation has been performed using the supersymmetric formulation of PQChPT as well as with a quark flow technique.
NASA Technical Reports Server (NTRS)
1972-01-01
This document is Volume 2 of three volumes of the Final Report for the four band Multispectral Scanner System (MSS). The results are contained of an analysis of pictures of actual outdoor scenes imaged by the engineering model MSS for spectral response, resolution, noise, and video correction. Also included are the results of engineering tests on the MSS for reflectance and saturation from clouds. Finally, two panoramic pictures of Yosemite National Park are provided.
Suppa, Per; Hampel, Harald; Spies, Lothar; Fiebach, Jochen B; Dubois, Bruno; Buchert, Ralph
2015-01-01
Hippocampus volumetry based on magnetic resonance imaging (MRI) has not yet been translated into everyday clinical diagnostic patient care, at least in part due to limited availability of appropriate software tools. In the present study, we evaluate a fully-automated and computationally efficient processing pipeline for atlas based hippocampal volumetry using freely available Statistical Parametric Mapping (SPM) software in 198 amnestic mild cognitive impairment (MCI) subjects from the Alzheimer's Disease Neuroimaging Initiative (ADNI1). Subjects were grouped into MCI stable and MCI to probable Alzheimer's disease (AD) converters according to follow-up diagnoses at 12, 24, and 36 months. Hippocampal grey matter volume (HGMV) was obtained from baseline T1-weighted MRI and then corrected for total intracranial volume and age. Average processing time per subject was less than 4 minutes on a standard PC. The area under the receiver operator characteristic curve of the corrected HGMV for identification of MCI to probable AD converters within 12, 24, and 36 months was 0.78, 0.72, and 0.71, respectively. Thus, hippocampal volume computed with the fully-automated processing pipeline provides similar power for prediction of MCI to probable AD conversion as computationally more expensive methods. The whole processing pipeline has been made freely available as an SPM8 toolbox. It is easily set up and integrated into everyday clinical patient care.
A Study on Micropipetting Detection Technology of Automatic Enzyme Immunoassay Analyzer.
Shang, Zhiwu; Zhou, Xiangping; Li, Cheng; Tsai, Sang-Bing
2018-04-10
In order to improve the accuracy and reliability of micropipetting, a method of micro-pipette detection and calibration combining the dynamic pressure monitoring in pipetting process and quantitative identification of pipette volume in image processing was proposed. Firstly, the normalized pressure model for the pipetting process was established with the kinematic model of the pipetting operation, and the pressure model is corrected by the experimental method. Through the pipetting process pressure and pressure of the first derivative of real-time monitoring, the use of segmentation of the double threshold method as pipetting fault evaluation criteria, and the pressure sensor data are processed by Kalman filtering, the accuracy of fault diagnosis is improved. When there is a fault, the pipette tip image is collected through the camera, extract the boundary of the liquid region by the background contrast method, and obtain the liquid volume in the tip according to the geometric characteristics of the pipette tip. The pipette deviation feedback to the automatic pipetting module and deviation correction is carried out. The titration test results show that the combination of the segmented pipetting kinematic model of the double threshold method of pressure monitoring, can effectively real-time judgment and classification of the pipette fault. The method of closed-loop adjustment of pipetting volume can effectively improve the accuracy and reliability of the pipetting system.
Relative Evaluation of the Independent Volume Measures of Caverns
DOE Office of Scientific and Technical Information (OSTI.GOV)
MUNSON,DARRELL E.
2000-08-01
Throughout the construction and operation of the caverns of the Strategic Petroleum Reserve (SPR), three types of cavern volume measurements have been maintained. These are: (1) the calculated solution volume determined during initial construction by solution mining and any subsequent solutioning during oil transfers, (2) the calculated sonar volume determined through sonar surveys of the cavern dimensions, and (3) the direct metering of oil to determine the volume of the cavern occupied by the oil. The objective of this study is to compare these measurements to each other and determine, if possible, the uncertainties associated with a given type ofmore » measurement. Over time, each type of measurement has acquired a customary, or an industry accepted, stated uncertainty. This uncertainty is not necessarily the result of a technical analysis. Ultimately there is one definitive quantity, the oil volume measure by the oil custody transfer meters, taken by all parties to the transfer as the correct ledger amount and for which the SPR Project is accountable. However, subsequent transfers within a site may not be with meters of the same accuracy. In this study, a very simple theory of the perfect relationship is used to evaluate the correlation (deviation) of the various measures. This theory permits separation of uncertainty and bias. Each of the four SPR sites are examined, first with comparisons between the calculated solution volumes and the sonar volumes determined during construction, then with comparisons of the oil inventories and the sonar volumes obtained either by surveying through brine prior to oil filling or through the oil directly.« less
Morphological phenotyping of mouse hearts using optical coherence tomography
NASA Astrophysics Data System (ADS)
Cua, Michelle; Lin, Eric; Lee, Ling; Sheng, Xiaoye; Wong, Kevin S. K.; Tibbits, Glen F.; Beg, Mirza Faisal; Sarunic, Marinko V.
2014-11-01
Transgenic mouse models have been instrumental in the elucidation of the molecular mechanisms behind many genetically based cardiovascular diseases such as Marfan syndrome (MFS). However, the characterization of their cardiac morphology has been hampered by the small size of the mouse heart. In this report, we adapted optical coherence tomography (OCT) for imaging fixed adult mouse hearts, and applied tools from computational anatomy to perform morphometric analyses. The hearts were first optically cleared and imaged from multiple perspectives. The acquired volumes were then corrected for refractive distortions, and registered and stitched together to form a single, high-resolution OCT volume of the whole heart. From this volume, various structures such as the valves and myofibril bundles were visualized. The volumetric nature of our dataset also allowed parameters such as wall thickness, ventricular wall masses, and luminal volumes to be extracted. Finally, we applied the entire acquisition and processing pipeline in a preliminary study comparing the cardiac morphology of wild-type mice and a transgenic mouse model of MFS.
Parsons, Teresa L.; Marzinke, Mark A.; Hoang, Thuy; Bliven-Sizemore, Erin; Weiner, Marc; Mac Kenzie, William R.; Dorman, Susan E.
2014-01-01
The quantification of antituberculosis drug concentrations in multinational trials currently requires the collection of modest blood volumes, centrifugation, aliquoting of plasma, freezing, and keeping samples frozen during shipping. We prospectively enrolled healthy individuals into the Tuberculosis Trials Consortium Study 29B, a phase I dose escalation study of rifapentine, a rifamycin under evaluation in tuberculosis treatment trials. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying rifapentine in whole blood on dried blood spots (DBS) to facilitate pharmacokinetic/pharmacodynamic analyses in clinical trials. Paired plasma and whole-blood samples were collected by venipuncture, and whole blood was spotted on Whatman protein saver 903 cards. The methods were optimized for plasma and then validated for DBS. The analytical measuring range for quantification of rifapentine and its metabolite was 50 to 80,000 ng/ml in whole-blood DBS. The analyte was stable on the cards for 11 weeks with a desiccant at room temperature and protected from light. The method concordance for paired plasma and whole-blood DBS samples was determined after correcting for participant hematocrit or population-based estimates of bias from Bland-Altman plots. The application of either correction factor resulted in acceptable correlation between plasma and whole-blood DBS (Passing-Bablok regression corrected for hematocrit; y = 0.98x + 356). Concentrations of rifapentine may be determined from whole-blood DBS collected via venipuncture after normalization in order to account for the dilutional effects of red blood cells. Additional studies are focused on the application of this methodology to capillary blood collected by finger stick. The simplicity of processing, storage, shipping, and low blood volume makes whole-blood DBS attractive for rifapentine pharmacokinetic evaluations, especially in international and pediatric trials. PMID:25182637
Lin, Longting; Bivard, Andrew; Kleinig, Timothy; Spratt, Neil J; Levi, Christopher R; Yang, Qing; Parsons, Mark W
2018-04-01
This study aimed to assess how the ischemic core measured by perfusion computed tomography (CTP) was affected by the delay and dispersion effect. Ischemic stroke patients having CTP performed within 6 hours of onset were included. The CTP data were processed twice, generating standard cerebral blood flow (sCBF) and delay- and dispersion-corrected CBF (ddCBF), respectively. Ischemic core measured by the sCBF and ddCBF was then compared at the relative threshold <30% of normal tissue. Two references for ischemic core were used: acute diffusion-weighted imaging or 24-hour diffusion-weighted imaging in patients with complete recanalization. Difference of core volume between CTP and diffusion-weighted imaging was estimated by Mann-Whitney U test and limits of agreement. Patients were also classified into favorable and unfavorable CTP patterns. The imaging pattern classification by sCBF and ddCBF was compared by the χ 2 test; their respective ability to predict good clinical outcome (3-month modified Rankin Scale score) was tested in logistic regression. Fifty-five patients were included in this study. Median sCBF ischemic core volume was 38.5 mL (12.4-61.9 mL), much larger than the median core volume of 17.2 mL measured by ddCBF (interquartile range, 5.5-38.8; P <0.001). Moreover, compared with sCBF <30%, ddCBF <30% measured the ischemic core much closer to diffusion-weighted imaging core references, with the mean volume difference of -0.1 mL (95% limits of agreement, -25.4 to 25.2; P =0.97) and 16.7 mL (95% limits of agreement, -21.7 to 55.2; P <0.001), respectively. Imaging patterns defined by sCBF showed a difference to that defined by ddCBF ( P <0.001), with 12 patients classified as favorable imaging patterns by ddCBF but as unfavorable by sCBF. The favorable imaging pattern classified by ddCBF, compared with sCBF classification, had higher predictive power for good clinical outcome (odds ratio, 7.8 [2-30.5] and 3.1 [0.9-11], respectively). Delay and dispersion correction increases the accuracy of ischemic core measurement on CTP. © 2018 American Heart Association, Inc.
Verification of ECMWF System 4 for seasonal hydrological forecasting in a northern climate
NASA Astrophysics Data System (ADS)
Bazile, Rachel; Boucher, Marie-Amélie; Perreault, Luc; Leconte, Robert
2017-11-01
Hydropower production requires optimal dam and reservoir management to prevent flooding damage and avoid operation losses. In a northern climate, where spring freshet constitutes the main inflow volume, seasonal forecasts can help to establish a yearly strategy. Long-term hydrological forecasts often rely on past observations of streamflow or meteorological data. Another alternative is to use ensemble meteorological forecasts produced by climate models. In this paper, those produced by the ECMWF (European Centre for Medium-Range Forecast) System 4 are examined and bias is characterized. Bias correction, through the linear scaling method, improves the performance of the raw ensemble meteorological forecasts in terms of continuous ranked probability score (CRPS). Then, three seasonal ensemble hydrological forecasting systems are compared: (1) the climatology of simulated streamflow, (2) the ensemble hydrological forecasts based on climatology (ESP) and (3) the hydrological forecasts based on bias-corrected ensemble meteorological forecasts from System 4 (corr-DSP). Simulated streamflow computed using observed meteorological data is used as benchmark. Accounting for initial conditions is valuable even for long-term forecasts. ESP and corr-DSP both outperform the climatology of simulated streamflow for lead times from 1 to 5 months depending on the season and watershed. Integrating information about future meteorological conditions also improves monthly volume forecasts. For the 1-month lead time, a gain exists for almost all watersheds during winter, summer and fall. However, volume forecasts performance for spring varies from one watershed to another. For most of them, the performance is close to the performance of ESP. For longer lead times, the CRPS skill score is mostly in favour of ESP, even if for many watersheds, ESP and corr-DSP have comparable skill. Corr-DSP appears quite reliable but, in some cases, under-dispersion or bias is observed. A more complex bias-correction method should be further investigated to remedy this weakness and take more advantage of the ensemble forecasts produced by the climate model. Overall, in this study, bias-corrected ensemble meteorological forecasts appear to be an interesting source of information for hydrological forecasting for lead times up to 1 month. They could also complement ESP for longer lead times.
NASA Astrophysics Data System (ADS)
Wang, Kunpeng; Tan, Handong; Zhang, Zhiyong; Li, Zhiqiang; Cao, Meng
2017-05-01
Resistivity anisotropy and full-tensor controlled-source audio-frequency magnetotellurics (CSAMT) have gradually become hot research topics. However, much of the current anisotropy research for tensor CSAMT only focuses on the one-dimensional (1D) solution. As the subsurface is rarely 1D, it is necessary to study three-dimensional (3D) model response. The staggered-grid finite difference method is an effective simulation method for 3D electromagnetic forward modelling. Previous studies have suggested using the divergence correction to constrain the iterative process when using a staggered-grid finite difference model so as to accelerate the 3D forward speed and enhance the computational accuracy. However, the traditional divergence correction method was developed assuming an isotropic medium. This paper improves the traditional isotropic divergence correction method and derivation process to meet the tensor CSAMT requirements for anisotropy using the volume integral of the divergence equation. This method is more intuitive, enabling a simple derivation of a discrete equation and then calculation of coefficients related to the anisotropic divergence correction equation. We validate the result of our 3D computational results by comparing them to the results computed using an anisotropic, controlled-source 2.5D program. The 3D resistivity anisotropy model allows us to evaluate the consequences of using the divergence correction at different frequencies and for two orthogonal finite length sources. Our results show that the divergence correction plays an important role in 3D tensor CSAMT resistivity anisotropy research and offers a solid foundation for inversion of CSAMT data collected over an anisotropic body.
Arhan, Ebru; Gücüyener, Kıvılcım; Soysal, Şebnem; Şalvarlı, Şafak; Gürses, M Ali; Serdaroğlu, Ayşe; Demir, Ercan; Ergenekon, Ebru; Türkyılmaz, Canan; Önal, Esra; Koç, Esin; Atalay, Yıldız
2017-08-01
More information is needed on "low-risk" preterm infants' neurological outcome so that they can be included in follow-up programs. A prospective study was performed to examine the regional brain volume changes compared to term children and to assess the relationship between the regional brain volumes to cognitive outcome of the low-risk preterm children at 9 years of age. Subjects comprised 22 preterm children who were determined to be at low risk for neurodevelopmental deficits with a gestational age between 28 and 33 weeks without a major neonatal morbidity in the neonatal period and 24 age-matched term control children term and matched for age, sex, and parental educational and occupational status. Regional volumetric analysis was performed for cerebellum, hippocampus, and corpus callosum area. Cognitive outcomes of both preterm and control subjects were assessed by Weschler Intelligence Scale for Children Revised (Turkish version), and attention and executive functions were assessed by Wisconsin Card Sorting Test and Stroop Test TBAG version. Low-risk preterm children showed regional brain volume reduction in cerebellum, hippocampus, and corpus callosum area and achieved statistical significance when compared with term control. When the groups were compared for all WISC-R subscale scores, preterm children at low risk had significantly lower scores on information, vocabulary, similarities, arithmetics, picture completion, block design, object assembly, and coding compared to children born at term. Preterm and term groups were compared on the Stroop Test for mistakes and corrections made on each card, the time spent for completing each card, and total mistakes and corrections. In the preterm group, we found a positive correlation between regional volumes with IQ, attention, and executive function scores. Additionally, a significant correlation was found between cerebellar volume and attention and executive function scores in the preterm group. Low-risk preterm children achieve lower scores in neurophysiological tests than children born at term. Preterm birth itself has a significant impact on regional brain volumes and cognitive outcome of children at 9 years of age. It is a risk factor for regional brain volume reductions in preterm children with low risk for neurodevelopmental deficits. The significant interaction between cerebellar volume reduction and executive function and attention may suggest that even in preterm children at low risk can have different trajectories in the growth and development of overall brain structure.
NASA Astrophysics Data System (ADS)
Lüdemann, L.; Sreenivasa, G.; Michel, R.; Rosner, C.; Plotkin, M.; Felix, R.; Wust, P.; Amthauer, H.
2006-06-01
Assessment of perfusion with 15O-labelled water (H215O) requires measurement of the arterial input function (AIF). The arterial time activity curve (TAC) measured using the peripheral sampling scheme requires corrections for delay and dispersion. In this study, parametrizations with and without arterial spillover correction for fitting of the tissue curve are evaluated. Additionally, a completely noninvasive method for generation of the AIF from a dynamic positron emission tomography (PET) acquisition is applied to assess perfusion of pelvic tumours. This method uses a volume of interest (VOI) to extract the TAC from the femoral artery. The VOI TAC is corrected for spillover using a separate tissue TAC and for recovery by determining the recovery coefficient on a coregistered CT data set. The techniques were applied in five patients with pelvic tumours who underwent a total of 11 examinations. Delay and dispersion correction of the blood TAC without arterial spillover correction yielded in seven examinations solutions inconsistent with physiology. Correction of arterial spillover increased the fitting accuracy and yielded consistent results in all patients. Generation of an AIF from PET image data was investigated as an alternative to arterial blood sampling and was shown to have an intrinsic potential to determine the AIF noninvasively and reproducibly. The AIF extracted from a VOI in a dynamic PET scan was similar in shape to the blood AIF but yielded significantly higher tissue perfusion values (mean of 104.0 ± 52.0%) and lower partition coefficients (-31.6 ± 24.2%). The perfusion values and partition coefficients determined with the VOI technique have to be corrected in order to compare the results with those of studies using a blood AIF.
On-orbit checkout of satellites, volume 2. Part 3 of on-orbit checkout study. [space maintenance
NASA Technical Reports Server (NTRS)
Pritchard, E. I.
1978-01-01
Early satellite failures significantly degrading satellite operations are reviewed with emphasis on LANDSAT D, the Technology Demonstration Satellite, the ATREX/AEM spacecraft, STORMSAT 2, and the synchronous meteorological satellite. Candidates for correction with on-orbit checkout and appropriate actions are analyzed. On-orbit checkout subsystem level studies are summarized for electrical power, attitude control, thermal control, reaction control and propulsion, instruments, and angular rate matching for alignment of satellite IRU.
Charged hadrons in local finite-volume QED+QCD with C⋆ boundary conditions
NASA Astrophysics Data System (ADS)
Lucini, B.; Patella, A.; Ramos, A.; Tantalo, N.
2016-02-01
In order to calculate QED corrections to hadronic physical quantities by means of lattice simulations, a coherent description of electrically-charged states in finite volume is needed. In the usual periodic setup, Gauss's law and large gauge transformations forbid the propagation of electrically-charged states. A possible solution to this problem, which does not violate the axioms of local quantum field theory, has been proposed by Wiese and Polley, and is based on the use of C⋆ boundary conditions. We present a thorough analysis of the properties and symmetries of QED in isolation and QED coupled to QCD, with C⋆ boundary conditions. In particular we learn that a certain class of electrically-charged states can be constructed in a fully consistent fashion without relying on gauge fixing and without peculiar complications. This class includes single particle states of most stable hadrons. We also calculate finite-volume corrections to the mass of stable charged particles and show that these are much smaller than in non-local formulations of QED.
NASA Astrophysics Data System (ADS)
Bauer, A.; Horstwood, M. S.
2016-12-01
Crust-mantle evolution studies are greatly informed by zircon U-Pb and Lu-Hf isotopic datasets and the ease with which these data can now be acquired has seen their application become commonplace. In order to deconvolute geochemical change and interpret geologic variation in complexly zoned zircons, this information is most ideally obtained on the smallest volume of zircon by successive SIMS U-Pb and LA-MC-ICP-MS Lu-Hf isotopic analyses. However, due to variations in zircon growth zone geometry at depth, the Lu-Hf analysis may not relate to the lower volume U-Pb analysis, potentially causing inaccuracy of the resultant age-corrected Hf isotope signature. Laser ablation split-stream methods are applied to be certain that U-Pb and Lu-Hf data represent the same volume of zircon, however, the sampling volume remains relatively large at 40x30µm1. Coupled ID-TIMS U-Pb and solution MC-ICP-MS Lu-Hf work traditionally utilize whole-zircon dissolution ( 10-50ng Hf), which has the potential to homogenize different zones of geologic significance within an analysis. Conversely, modern ID-TIMS U-Pb methods utilize microsampling of zircon grains, often providing < 5ng Hf, thereby challenging conventional Lu-Hf acquisition protocols to achieve the required precision. In order to obtain usable precision on minimal zircon volumes, we developed laser ablation methods using successive 25um spot U-Pb and Lu-Hf ablation pits with a combined depth of 18um, and low-volume solution introduction methods without Hf-REE separation utilizing Hf amounts as low as 0.4ng, while retaining an uncertainty level of ca. 1 ɛHf for both methods. We investigated methods of Yb interference correction and the potential for matrix effects, with a particular focus on the accurate quantification of 176Lu/177Hf. These improvements reduce the minimum amount of material required for U-Pb and Hf isotopic analysis of zircon by about an order of magnitude. 1Ibanez-Mejia et al (2015). PreRes, 267, 285-310.
NASA Astrophysics Data System (ADS)
Delhaye, Robert; Rath, Volker; Jones, Alan G.; Muller, Mark R.; Reay, Derek
2017-05-01
Galvanic distortions of magnetotelluric (MT) data, such as the static-shift effect, are a known problem that can lead to incorrect estimation of resistivities and erroneous modelling of geometries with resulting misinterpretation of subsurface electrical resistivity structure. A wide variety of approaches have been proposed to account for these galvanic distortions, some depending on the target area, with varying degrees of success. The natural laboratory for our study is a hydraulically permeable volume of conductive sediment at depth, the internal resistivity structure of which can be used to estimate reservoir viability for geothermal purposes; however, static-shift correction is required in order to ensure robust and precise modelling accuracy.We present here a possible method to employ frequency-domain electromagnetic data in order to correct static-shift effects, illustrated by a case study from Northern Ireland. In our survey area, airborne frequency domain electromagnetic (FDEM) data are regionally available with high spatial density. The spatial distributions of the derived static-shift corrections are analysed and applied to the uncorrected MT data prior to inversion. Two comparative inversion models are derived, one with and one without static-shift corrections, with instructive results. As expected from the one-dimensional analogy of static-shift correction, at shallow model depths, where the structure is controlled by a single local MT site, the correction of static-shift effects leads to vertical scaling of resistivity-thickness products in the model, with the corrected model showing improved correlation to existing borehole wireline resistivity data. In turn, as these vertical scalings are effectively independent of adjacent sites, lateral resistivity distributions are also affected, with up to half a decade of resistivity variation between the models estimated at depths down to 2000 m. Simple estimation of differences in bulk porosity, derived using Archie's Law, between the two models reinforces our conclusion that the suborder of magnitude resistivity contrasts induced by the correction of static shifts correspond to similar contrasts in estimated porosities, and hence, for purposes of reservoir investigation or similar cases requiring accurate absolute resistivity estimates, galvanic distortion correction, especially static-shift correction, is essential.
The influence of RBE variations in a clinical proton treatment plan for a hypopharynx cancer
NASA Astrophysics Data System (ADS)
Tilly, N.; Johansson, J.; Isacsson, U.; Medin, J.; Blomquist, E.; Grusell, E.; Glimelius, B.
2005-06-01
Currently, most clinical range-modulated proton beams are assumed to have a fixed overall relative biological effectiveness (RBE) of 1.1. However, it is well known that the RBE increases with depth in the spread-out Bragg peak (SOBP) and becomes about 10% higher than mid-SOBP RBE at 2 mm from the distal edge (Paganetti 2003 Technol. Cancer Res. Treat. 2 413-26) and can reach values of 1.3-1.4 in vitro at the distal edge (Robertson et al 1975 Cancer 35 1664-77, Courdi et al 1994 Br. J. Radiol. 67 800-4). We present a fast method for applying a variable RBE correction with linear energy transfer (LET) dependent tissue-specific parameters based on the αref/βref ratios suitable for implementation in a treatment planning system. The influence of applying this variable RBE correction on a clinical multiple beam proton dose plan is presented here. The treatment plan is evaluated by RBE weighted dose volume histograms (DVHs) and the calculation of tumour control probability (TCP) and normal tissue complication probability (NTCP) values. The variable RBE correction yields DVHs for the clinical target volumes (CTVs), a primary advanced hypopharynx cancer and subclinical disease in the lymph nodes, that are slightly higher than those achieved by multiplying the absorbed dose with RBE = 1.1. Although, more importantly, the RBE weighted DVH for an organ at risk, the spinal cord is considerably increased for the variable RBE. As the spinal cord in this particular case is located 8 mm behind the planning target volume (PTV) and hence receives only low total doses, the NTCP values are zero in spite of the significant increase in the RBE weighted DVHs for the variable RBE. However, high NTCP values for the non-target normal tissue were obtained when applying the variable RBE correction. As RBE variations tend to be smaller for in vivo systems, this study—based on in vitro data since human tissue RBE values are scarce and have large uncertainties—can be interpreted as showing the upper limits of the possible effects of utilizing a variable RBE correction. In conclusion, the results obtained here still indicate a significant difference in introducing a variable RBE compared to applying a generic RBE of 1.1, suggesting it is worth considering such a correction in clinical proton therapy planning, especially when risk organs are located immediately behind the target volume.
NASA Astrophysics Data System (ADS)
Marchant, T. E.; Joshi, K. D.; Moore, C. J.
2018-03-01
Radiotherapy dose calculations based on cone-beam CT (CBCT) images can be inaccurate due to unreliable Hounsfield units (HU) in the CBCT. Deformable image registration of planning CT images to CBCT, and direct correction of CBCT image values are two methods proposed to allow heterogeneity corrected dose calculations based on CBCT. In this paper we compare the accuracy and robustness of these two approaches. CBCT images for 44 patients were used including pelvis, lung and head & neck sites. CBCT HU were corrected using a ‘shading correction’ algorithm and via deformable registration of planning CT to CBCT using either Elastix or Niftyreg. Radiotherapy dose distributions were re-calculated with heterogeneity correction based on the corrected CBCT and several relevant dose metrics for target and OAR volumes were calculated. Accuracy of CBCT based dose metrics was determined using an ‘override ratio’ method where the ratio of the dose metric to that calculated on a bulk-density assigned version of the same image is assumed to be constant for each patient, allowing comparison to the patient’s planning CT as a gold standard. Similar performance is achieved by shading corrected CBCT and both deformable registration algorithms, with mean and standard deviation of dose metric error less than 1% for all sites studied. For lung images, use of deformed CT leads to slightly larger standard deviation of dose metric error than shading corrected CBCT with more dose metric errors greater than 2% observed (7% versus 1%).
1993-07-01
LPLPW3t TIME XXXX\\ LISI ADDRESSES AND DISIRIBUTION FOR XX XXXXXXXXXXXXXXXXXX\\ LSER ID XXX P %G[ ZZ.zz9 AA MLG MAILING ADDRESS ZIP CODE PI C x XNXX XX...4100.39-M Volume Is APPENDIX C AMLS INFORMATIONAL MESSAGES Corrective Action: Press the F6 ( COM MIT) function key to add the Distribution information
NASA Astrophysics Data System (ADS)
Jonasson, L. S.; Axelsson, J.; Riklund, K.; Boraxbekk, C. J.
2017-07-01
In longitudinal positron emission tomography (PET), the presence of volumetric changes over time can lead to an overestimation or underestimation of the true changes in the quantified PET signal due to the partial volume effect (PVE) introduced by the limited spatial resolution of existing PET cameras and reconstruction algorithms. Here, a 3D-printed anthropomorphic brain phantom with attachable striata in three sizes was designed to enable controlled volumetric changes. Using a method to eliminate the non-radioactive plastic wall, and manipulating BP levels by adding different number of events from list-mode acquisitions, we investigated the artificial volume dependence of BP due to PVE, and potential bias arising from varying BP. Comparing multiple reconstruction algorithms we found that a high-resolution ordered-subsets maximization algorithm with spatially variant point-spread function resolution modeling provided the most accurate data. For striatum, the BP changed by 0.08% for every 1% volume change, but for smaller volumes such as the posterior caudate the artificial change in BP was as high as 0.7% per 1% volume change. A simple gross correction for striatal volume is unsatisfactory, as the amplitude of the PVE on the BP differs depending on where in the striatum the change occurred. Therefore, to correctly interpret age-related longitudinal changes in the BP, we must account for volumetric changes also within a structure, rather than across the whole volume. The present 3D-printing technology, combined with the wall removal method, can be implemented to gain knowledge about the predictable bias introduced by the PVE differences in uptake regions of varying shape.
Erickson, Kirk I.; Suever, Barbara L.; Shaurya Prakash, Ruchika; Colcombe, Stanley J.; McAuley, Edward; Kramer, Arthur F.
2008-01-01
Previous studies have reported that high concentrations of homocysteine and lower concentrations of vitamin B6, B12, and folate increase the risk for cognitive decline and pathology in aging populations. In this cross-sectional study, high-resolution magnetic resonance imaging (MRI) scans and a 3-day food diary were collected on 32 community-dwelling adults between the ages of 59 and 79. We examined the relation between vitamin B6, B12, and folate intake on cortical volume using an optimized voxel-based morphometry (VBM) method and global gray and white matter volume after correcting for age, sex, body mass index, calorie intake, and education. All participants met or surpassed the recommended daily intake for these vitamins. In the VBM analysis, we found that adults with greater vitamin B6 intake had greater gray matter volume along the medial wall, anterior cingulate cortex, medial parietal cortex, middle temporal gyrus, and superior frontal gyrus, whereas people with greater B12 intake had greater volume in the left and right superior parietal sulcus. These effects were driven by vitamin supplementation and were negated when only examining vitamin intake from diet. Folate had no effect on brain volume. Furthermore, there was no relationship between vitamin B6, B12, or folate intake on global brain volume measures, indicating that VBM methods are more sensitive for detecting localized differences in gray matter volume than global measures. These results are discussed in relation to a growing literature on vitamin intake on age-related neurocognitive deterioration. PMID:18281020
Sexual dimorphism of canine volume: a pilot study.
De Angelis, Danilo; Gibelli, Daniele; Gaudio, Daniel; Cipriani Noce, Filippo; Guercini, Nicola; Varvara, Giuseppe; Sguazza, Emanuela; Sforza, Chiarella; Cattaneo, Cristina
2015-05-01
Sex assessment is a crucial part of the biological profile in forensic and archaeological context, but it can be hardly performed in cases of commingled and charred human remains where DNA tests often are not applicable. With time literature have analyzed the sexual dimorphism of teeth (and especially canines), but very few articles take into consideration the teeth volume, although with time several technologies have been introduced in order to assess 3D volume (CT-scan, laser scanner, etc.). This study aims at assessing the sexual dimorphism of dental and pulp chamber volumes of a sample of canines. Cone beam computed tomography analyses were performed by 87 patients (41 males and 46 females, aged between 15 and 83 years) for clinical purposes, and were acquired in order to measure canine volumes. Results show that the dental volume amounted to 0.745 cm(3) (SD 0.126 cm(3)) in males, 0.551 cm(3) (SD 0.130 cm(3)) with a statistically significant difference (p<0.01). A diagnostic threshold of 0.619 cm(3) was stated, which provides a percentage of correct answer of 80.5% in the chosen sample. The novel method was then applied with success to 7 archaeological: where in all the cases the results were concordant with those provided by the assessment of the cranium and pelvis. The study adds a contribution to the wide analysis of dental sexual dimorphism confirming the statistically significant differences of volume between males and females and providing a method for the diagnosis of sex applicable to forensic cases. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yin, L; Lin, A; Ahn, P
Purpose: To utilize online CBCT scans to develop models for predicting DVH metrics in proton therapy of head and neck tumors. Methods: Nine patients with locally advanced oropharyngeal cancer were retrospectively selected in this study. Deformable image registration was applied to the simulation CT, target volumes, and organs at risk (OARs) contours onto each weekly CBCT scan. Intensity modulated proton therapy (IMPT) treatment plans were created on the simulation CT and forward calculated onto each corrected CBCT scan. Thirty six potentially predictive metrics were extracted from each corrected CBCT. These features include minimum/maximum/mean over and under-ranges at the proximal andmore » distal surface of PTV volumes, and geometrical and water equivalent distance between PTV and each OARs. Principal component analysis (PCA) was used to reduce the dimension of the extracted features. Three principal components were found to account for over 90% of variances in those features. Datasets from eight patients were used to train a machine learning model to fit these principal components with DVH metrics (dose to 95% and 5% of PTV, mean dose or max dose to OARs) from the forward calculated dose on each corrected CBCT. The accuracy of this model was verified on the datasets from the 9th patient. Results: The predicted changes of DVH metrics from the model were in good agreement with actual values calculated on corrected CBCT images. Median differences were within 1 Gy for most DVH metrics except for larynx and constrictor mean dose. However, a large spread of the differences was observed, indicating additional training datasets and predictive features are needed to improve the model. Conclusion: Intensity corrected CBCT scans hold the potential to be used for online verification of proton therapy and prediction of delivered dose distributions.« less
Development of a 3D remote dosimetry protocol compatible with MRgIMRT.
Mein, Stewart; Rankine, Leith; Adamovics, John; Li, Harold; Oldham, Mark
2017-11-01
To develop a novel remote 3D dosimetry protocol to verify Magnetic Resonance-guided Radiation Therapy (MRgRT) treatments. The protocol was applied to investigate the accuracy of TG-119 IMRT irradiations delivered by the MRIdian ® system (ViewRay ® , Oakwood Village, OH, USA) allowing for a 48-hour delay between irradiation at a field institution and subsequent readout at a base institution. The 3D dosimetry protocol utilizes a novel formulation of PRESAGE ® radiochromic dosimeters developed for high postirradiation stability and compatibility with optical-CT readout. Optical-CT readout was performed with an in-house system utilizing telecentric lenses affording high-resolution scanning. The protocol was developed from preparatory experiments to characterize PRESAGE ® response in relevant conditions. First, linearity and sensitivity of PRESAGE ® dose-response in the presence of a magnetic field was evaluated in a small volume study (4 ml cuvettes) conducted under MRgRT conditions and irradiated with doses 0-15 Gy. Temporal and spatial stability of the dose-response were investigated in large volume studies utilizing large field-of-view (FOV) 2 kg cylindrical PRESAGE ® dosimeters. Dosimeters were imaged at t = 1 hr and t = 48 hrs enabling the development of correction terms to model any observed spatial and temporal changes postirradiation. Polynomial correction factors for temporal and spatial changes in PRESAGE ® dosimeters (C T and C R respectively) were obtained by numerical fitting to time-point data acquired in six irradiated dosimeters. A remote dosimetry protocol was developed where PRESAGE ® change in optical-density (ΔOD) readings at time t = X (the irradiation to return shipment time interval) were corrected back to a convenient standard time t = 1 hr using the C T and C R corrections. This refined protocol was then applied to TG-119 (American Association of Physicists in Medicine, Task Group 119) plan deliveries on the MRIdian ® system to evaluate the accuracy of MRgRT in these conditions. In the small volume study, in the presence of a 0.35 T magnetic field, PRESAGE ® was observed to respond linearly (R 2 = 0.9996) to Co-60 irradiation at t = 48 hrs postirradiation, within the dose ranges of 0 to 15 Gy, with a sensitivity of 0.0305(±0.003) ΔOD cm -1 Gy -1 . In the large volume studies, at t = 1 hr postirradiation, consistent linear response was observed, with average sensitivity of 0.0930 ± 0.002 ΔOD cm -1 Gy -1 . However, dosimeters gradually darkened with time (OD< 5% per day). A small radial dependence to the dosimeter sensitivity was measured (< 3% of maximum dose), which is attributed to a spherically symmetric dosimeter artifact arising from exothermic heating legacy in the PRESAGE ® polyurethane substrate during curing. When applied to the TG-119 IMRT irradiations, the remote dosimetry protocol (including correction terms) yielded excellent line-profile and 3D gamma agreement for 3%/3 mm, 10% threshold (mean passing rate = 96.6% ± 4.0%). A novel 3D remote dosimetry protocol is introduced for validating off-site dosimetrically complex radiotherapy systems, including MRgRT. The protocol involves correcting for temporal and spatially dependent changes in PRESAGE ® radiochromic dosimeters readout by optical-CT. Application of the protocol to TG-119 irradiations enabled verification of MRgRT dose distributions with high resolution. © 2017 American Association of Physicists in Medicine.
Kurbatov, Dmitry; Russo, Giorgio Ivan; Galstyan, G R; Rozhivanov, Roman; Lepetukhin, Alexander; Dubsky, Sergey; Shwartz, Y G; Cimino, Sebastiano; Morgia, Giuseppe; Sansalone, Salvatore
2015-11-01
Diabetic neuropathy secondary to diabetes mellitus type 1 (DM1) is responsible for retrograde ejaculation (RE) in 5-18% of cases. Medical treatment of RE is based either on increasing the sympathetic tone of the bladder or on decreasing the parasympathetic activity. However, the onset of side effects and the lack of response should be considered. The aim of this study was to analyze long-term outcome of endourethral injection of volume-forming material (VFM) of collagen type 2 into bladder neck submucosa in patients with RE secondary to DM1. Twenty-four patients with complete RE refractory to imipramine and DM1 were included in the study. Patients were single-blinded randomized according to a computer-generated random sequence with a 1:1 ratio in two treatment groups, namely group A (endourethral collage type 2 injection) and group B (endourethral saline water injection). New technique includes an endoscopic injection of VFM such as collagen (Correcting MIT®, Ltd. minimally invasive technologies, Moscow, Russia) into bladder neck submucosa. Primary endpoint of the study was the reduction of semen antegrade volume (mL). Secondary endpoints were considered as the changes of antegrade count (millions/mL), antegrade total motility (%), antegrade progressive motility (%), State-Trait Anxiety Inventory, Beck Depression Questionnaire and International Index of Erectile Function (IIEF-5). Pregnancy rate was calculated in each group. Twenty-three patients completed the study. In group A, significant differences from baseline to 12 months were observed relative to antegrade volume (mL) (mean difference: 0.71, P < 0.05), antegrade count (millions/mL) (mean difference: 45.6, P < 0.05), antegrade total motility (%) (mean difference: 15.4, P < 0.05) and antegrade progressive motility (%) (mean difference: 8.4, P < 0.05). In group A, we observed significant differences in terms State-Trait Anxiety Inventory (mean difference: -20.5, P < 0.05) and Beck Depression Inventory (mean difference: -8.4, P < 0.05) with significant differences compared with group B. We observed significant improvements in group A vs. group B when considering primary and secondary endpoints of the study, but not for the IIEF-5. Correction of RE in DM1 patients could be achieved with endourethral injection of collagen type 2. © 2015 International Society for Sexual Medicine.
MRI-assisted PET motion correction for neurologic studies in an integrated MR-PET scanner.
Catana, Ciprian; Benner, Thomas; van der Kouwe, Andre; Byars, Larry; Hamm, Michael; Chonde, Daniel B; Michel, Christian J; El Fakhri, Georges; Schmand, Matthias; Sorensen, A Gregory
2011-01-01
Head motion is difficult to avoid in long PET studies, degrading the image quality and offsetting the benefit of using a high-resolution scanner. As a potential solution in an integrated MR-PET scanner, the simultaneously acquired MRI data can be used for motion tracking. In this work, a novel algorithm for data processing and rigid-body motion correction (MC) for the MRI-compatible BrainPET prototype scanner is described, and proof-of-principle phantom and human studies are presented. To account for motion, the PET prompt and random coincidences and sensitivity data for postnormalization were processed in the line-of-response (LOR) space according to the MRI-derived motion estimates. The processing time on the standard BrainPET workstation is approximately 16 s for each motion estimate. After rebinning in the sinogram space, the motion corrected data were summed, and the PET volume was reconstructed using the attenuation and scatter sinograms in the reference position. The accuracy of the MC algorithm was first tested using a Hoffman phantom. Next, human volunteer studies were performed, and motion estimates were obtained using 2 high-temporal-resolution MRI-based motion-tracking techniques. After accounting for the misalignment between the 2 scanners, perfectly coregistered MRI and PET volumes were reproducibly obtained. The MRI output gates inserted into the PET list-mode allow the temporal correlation of the 2 datasets within 0.2 ms. The Hoffman phantom volume reconstructed by processing the PET data in the LOR space was similar to the one obtained by processing the data using the standard methods and applying the MC in the image space, demonstrating the quantitative accuracy of the procedure. In human volunteer studies, motion estimates were obtained from echo planar imaging and cloverleaf navigator sequences every 3 s and 20 ms, respectively. Motion-deblurred PET images, with excellent delineation of specific brain structures, were obtained using these 2 MRI-based estimates. An MRI-based MC algorithm was implemented for an integrated MR-PET scanner. High-temporal-resolution MRI-derived motion estimates (obtained while simultaneously acquiring anatomic or functional MRI data) can be used for PET MC. An MRI-based MC method has the potential to improve PET image quality, increasing its reliability, reproducibility, and quantitative accuracy, and to benefit many neurologic applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hurwitz, R.A.; Treves, S.; Freed, M.
The ability to quantitate aortic (AR) or mitral regurgitation (MR), or both, by radionuclide angiocardiography was evaluated in children and young adults at rest and during isometric exercise. Regurgitation was estimated by determining the ratio of left ventricular stroke volume to right ventricular stroke volume obtained during equilibrium ventriculography. The radionuclide measurement was compared with results of cineangiography, with good correlation between both studies in 47 of 48 patients. Radionuclide stroke volume ratio was used to classify severity: the group with equivocal regurgitation differed from the group with mild regurgitation (p less than 0.02); patients with mild regurgitation differed frommore » those with moderate regurgitation (p less than 0.001); and those with moderate regurgitation differed from those with severe regurgitation (p less than 0.01). The stroke volume ratio was responsive to isometric exercise, remaining constant or increasing in 16 of 18 patients. After surgery to correct regurgitation, the stroke volume ratio significantly decreased from preoperative measurements in all 7 patients evaluated. Results from the present study demonstrate that a stroke volume ratio greater than 2.0 is compatible with moderately severe regurgitation and that a ratio greater than 3.0 suggests the presence of severe regurgitation. Thus, radionuclide angiocardiography should be useful for noninvasive quantitation of AR or MR, or both, helping define the course of young patients with left-side valvular regurgitation.« less
Supine posture changes lung volumes and increases ventilation heterogeneity in cystic fibrosis.
Smith, Laurie J; Macleod, Kenneth A; Collier, Guilhem J; Horn, Felix C; Sheridan, Helen; Aldag, Ina; Taylor, Chris J; Cunningham, Steve; Wild, Jim M; Horsley, Alex
2017-01-01
Lung Clearance Index (LCI) is recognised as an early marker of cystic fibrosis (CF) lung disease. The effect of posture on LCI however is important when considering longitudinal measurements from infancy and when comparing LCI to imaging studies. 35 children with CF and 28 healthy controls (HC) were assessed. Multiple breath washout (MBW) was performed both sitting and supine in triplicate and analysed for LCI, Scond, Sacin, and lung volumes. These values were also corrected for the Fowler dead-space to create 'alveolar' indices. From sitting to supine there was a significant increase in LCI and a significant decrease in FRC for both CF and HC (p<0.01). LCI, when adjusted to estimate 'alveolar' LCI (LCIalv), increased the magnitude of change with posture for both LCIalv and FRCalv in both groups, with a greater effect of change in lung volume in HC compared with children with CF. The % change in LCIalv for all subjects correlated significantly with lung volume % changes, most notably tidal volume/functional residual capacity (Vtalv/FRCalv (r = 0.54,p<0.001)). There is a significant increase in LCI from sitting to supine, which we believe to be in part due to changes in lung volume and also increasing ventilation heterogeneity related to posture. This may have implications in longitudinal measurements from infancy to older childhood and for studies comparing supine imaging methods to LCI.
Assessment of volume and leak measurements during CPAP using a neonatal lung model.
Fischer, H S; Roehr, C C; Proquitté, H; Wauer, R R; Schmalisch, G
2008-01-01
Although several commercial devices are available which allow tidal volume and air leak monitoring during continuous positive airway pressure (CPAP) in neonates, little is known about their measurement accuracy and about the influence of air leaks on volume measurement. The aim of this in vitro study was the validation of volume and leak measurement under CPAP using a commercial ventilatory device, taking into consideration the clinical conditions in neonatology. The measurement accuracy of the Leoni ventilator (Heinen & Löwenstein, Germany) was investigated both in a leak-free system and with leaks simulated using calibration syringes (2-10 ml, 20-100 ml) and a mechanical lung model. Open tubes of variable lengths were connected for leak simulation. Leak flow was measured with the flow-through technique. In a leak-free system the mean relative volume error +/-SD was 3.5 +/- 2.6% (2-10 ml) and 5.9 +/- 0.7% (20-60 ml), respectively. The influence of CPAP level, driving flow, respiratory rate and humidification of the breathing gas on the volume error was negligible. However, an increasing F(i)O(2) caused the measured tidal volume to increase by up to 25% (F(i)O(2) = 1.0). The relative error +/- SD of the leak measurements was -0.2 +/- 11.9%. For leaks > 19%, measured tidal volume was underestimated by more than 10%. In conclusion, the present in vitro study showed that the Leoni allowed accurate volume monitoring under CPAP conditions similar to neonates. Air leaks of up to 90% of patient flow were reliably detected. For an F(i)O(2) > 0.4 and for leaks > 19%, a numerical correction of the displayed volume should be performed.
Venturelli, Massimo; Jeong, Eun-Kee; Richardson, Russell S.
2014-01-01
The assessment of muscle volume, and changes over time, have significant clinical and research-related implications. Methods to assess muscle volume vary from simple and inexpensive to complex and expensive. Therefore this study sought to examine the validity of muscle volume estimated simply by anthropometry compared with the more complex proton magnetic resonance imaging (1H-MRI) across a wide spectrum of individuals including those with a spinal cord injury (SCI), a group recognized to exhibit significant muscle atrophy. Accordingly, muscle volume of the thigh and lower leg of eight subjects with a SCI and eight able-bodied subjects (controls) was determined by anthropometry and 1H-MRI. With either method, muscle volumes were significantly lower in the SCI compared with the controls (P < 0.05) and, using pooled data from both groups, anthropometric measurements of muscle volume were strongly correlated to the values assessed by 1H-MRI in both the thigh (r2 = 0.89; P < 0.05) and lower leg (r2 = 0.98; P < 0.05). However, the anthropometric approach systematically overestimated muscle volume compared with 1H-MRI in both the thigh (mean bias = 2407cm3) and the lower (mean bias = 170 cm3) leg. Thus with an appropriate correction for this systemic overestimation, muscle volume estimated from anthropometric measurements is a valid approach and provides acceptable accuracy across a spectrum of adults with normal muscle mass to a SCI and severe muscle atrophy. In practical terms this study provides the formulas that add validity to the already simple and inexpensive anthropometric approach to assess muscle volume in clinical and research settings. PMID:24458749
WE-G-18A-03: Cone Artifacts Correction in Iterative Cone Beam CT Reconstruction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yan, H; Folkerts, M; Jiang, S
Purpose: For iterative reconstruction (IR) in cone-beam CT (CBCT) imaging, data truncation along the superior-inferior (SI) direction causes severe cone artifacts in the reconstructed CBCT volume images. Not only does it reduce the effective SI coverage of the reconstructed volume, it also hinders the IR algorithm convergence. This is particular a problem for regularization based IR, where smoothing type regularization operations tend to propagate the artifacts to a large area. It is our purpose to develop a practical cone artifacts correction solution. Methods: We found it is the missing data residing in the truncated cone area that leads to inconsistencymore » between the calculated forward projections and measured projections. We overcome this problem by using FDK type reconstruction to estimate the missing data and design weighting factors to compensate the inconsistency caused by the missing data. We validate the proposed methods in our multi-GPU low-dose CBCT reconstruction system on multiple patients' datasets. Results: Compared to the FDK reconstruction with full datasets, while IR is able to reconstruct CBCT images using a subset of projection data, the severe cone artifacts degrade overall image quality. For head-neck case under a full-fan mode, 13 out of 80 slices are contaminated. It is even more severe in pelvis case under half-fan mode, where 36 out of 80 slices are affected, leading to inferior soft-tissue delineation. By applying the proposed method, the cone artifacts are effectively corrected, with a mean intensity difference decreased from ∼497 HU to ∼39HU for those contaminated slices. Conclusion: A practical and effective solution for cone artifacts correction is proposed and validated in CBCT IR algorithm. This study is supported in part by NIH (1R01CA154747-01)« less
Dosimetric verification of IMRT treatment planning using Monte Carlo simulations for prostate cancer
NASA Astrophysics Data System (ADS)
Yang, J.; Li, J.; Chen, L.; Price, R.; McNeeley, S.; Qin, L.; Wang, L.; Xiong, W.; Ma, C.-M.
2005-03-01
The purpose of this work is to investigate the accuracy of dose calculation of a commercial treatment planning system (Corvus, Normos Corp., Sewickley, PA). In this study, 30 prostate intensity-modulated radiotherapy (IMRT) treatment plans from the commercial treatment planning system were recalculated using the Monte Carlo method. Dose-volume histograms and isodose distributions were compared. Other quantities such as minimum dose to the target (Dmin), the dose received by 98% of the target volume (D98), dose at the isocentre (Diso), mean target dose (Dmean) and the maximum critical structure dose (Dmax) were also evaluated based on our clinical criteria. For coplanar plans, the dose differences between Monte Carlo and the commercial treatment planning system with and without heterogeneity correction were not significant. The differences in the isocentre dose between the commercial treatment planning system and Monte Carlo simulations were less than 3% for all coplanar cases. The differences on D98 were less than 2% on average. The differences in the mean dose to the target between the commercial system and Monte Carlo results were within 3%. The differences in the maximum bladder dose were within 3% for most cases. The maximum dose differences for the rectum were less than 4% for all the cases. For non-coplanar plans, the difference in the minimum target dose between the treatment planning system and Monte Carlo calculations was up to 9% if the heterogeneity correction was not applied in Corvus. This was caused by the excessive attenuation of the non-coplanar beams by the femurs. When the heterogeneity correction was applied in Corvus, the differences were reduced significantly. These results suggest that heterogeneity correction should be used in dose calculation for prostate cancer with non-coplanar beam arrangements.
ERIC Educational Resources Information Center
Walker, Janet S., Ed.
2006-01-01
This issue of "Focal Point" describes the need for, and provides examples of, new strategies for meeting the mental health needs of children and adolescents involved with the juvenile justice system. Articles in this issue discuss the particular need for correction in the way that the juvenile justice system interacts with youth who have mental…
Thomas B. Lynch; Jeffrey H. Gove
2014-01-01
The typical "double counting" application of the mirage method of boundary correction cannot be applied to sampling systems such as critical height sampling (CHS) that are based on a Monte Carlo sample of a tree (or debris) attribute because the critical height (or other random attribute) sampled from a mirage point is generally not equal to the critical...
Real Time System for Practical Acoustic Monitoring of Global Ocean Temperature. Volume 3
1994-06-30
signal processing software to the SSAR. This software performs Doppler correction , circulating sums, matched filtering and pulse compression, estimation...Doppler correction , circulating sums, matched filtering and pulse compression, estimation of multipath arrival angle, and peak- picking. At the... geometrica , sound speed, and focuing region sAles to the acoustic wavelengths Our work on this problem is based on an oceanographic application. To
Dosimetry for Small and Nonstandard Fields
NASA Astrophysics Data System (ADS)
Junell, Stephanie L.
The proposed small and non-standard field dosimetry protocol from the joint International Atomic Energy Agency (IAEA) and American Association of Physicist in Medicine working group introduces new reference field conditions for ionization chamber based reference dosimetry. Absorbed dose beam quality conversion factors (kQ factors) corresponding to this formalism were determined for three different models of ionization chambers: a Farmer-type ionization chamber, a thimble ionization chamber, and a small volume ionization chamber. Beam quality correction factor measurements were made in a specially developed cylindrical polymethyl methacrylate (PMMA) phantom and a water phantom using thermoluminescent dosimeters (TLDs) and alanine dosimeters to determine dose to water. The TLD system for absorbed dose to water determination in high energy photon and electron beams was fully characterized as part of this dissertation. The behavior of the beam quality correction factor was observed as it transfers the calibration coefficient from the University of Wisconsin Accredited Dosimetry Calibration Laboratory (UWADCL) 60Co reference beam to the small field calibration conditions of the small field formalism. TLD-determined beam quality correction factors for the calibration conditions investigated ranged from 0.97 to 1.30 and had associated standard deviations from 1% to 3%. The alanine-determined beam quality correction factors ranged from 0.996 to 1.293. Volume averaging effects were observed with the Farmer-type ionization chamber in the small static field conditions. The proposed small and non-standard field dosimetry protocols new composite-field reference condition demonstrated its potential to reduce or remove ionization chamber volume dependancies, but the measured beam quality correction factors were not equal to the standard CoP's kQ, indicating a change in beam quality in the small and non-standard field dosimetry protocols new composite-field reference condition relative to the standard broad beam reference conditions. The TLD- and alanine-determined beam quality correction factors in the composite-field reference conditions were approximately 3% greater and differed by more than one standard deviation from the published TG-51 kQ values for all three chambers.
Experimental determination of the PTW 60019 microDiamond dosimeter active area and volume
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marinelli, Marco, E-mail: marco.marinelli@uniroma2
Purpose: Small field output correction factors have been studied by several research groups for the PTW 60019 microDiamond (MD) dosimeter, by comparing the response of such a device with both reference dosimeters and Monte Carlo simulations. A general good agreement is observed for field sizes down to about 1 cm. However, evident inconsistencies can be noticed when comparing some experimental results and Monte Carlo simulations obtained for smaller irradiation fields. This issue was tentatively attributed by some authors to unintentional large variations of the MD active surface area. The aim of the present study is a nondestructive experimental determination ofmore » the MD active surface area and active volume. Methods: Ten MD dosimeters, one MD prototype, and three synthetic diamond samples were investigated in the present work. 2D maps of the MD response were recorded under scanned soft x-ray microbeam irradiation, leading to an experimental determination of the device active surface area. Profiles of the device responses were measured as well. In order to evaluate the MD active volume, the thickness of the diamond sensing layer was independently evaluated by capacitance measurements and alpha particle detection experiments. The MD sensitivity, measured at the PTW calibration laboratory, was also used to calculate the device active volume thickness. Results: An average active surface area diameter of (2.19 ± 0.02) mm was evaluated by 2D maps and response profiles of all the MDs. Average active volume thicknesses of (1.01 ± 0.13) μm and (0.97 ± 0.14) μm were derived by capacitance and sensitivity measurements, respectively. The obtained results are well in agreement with the nominal values reported in the manufacturer dosimeter specifications. A homogeneous response was observed over the whole device active area. Besides the one from the device active volume, no contributions from other components of the housing nor from encapsulation materials were observed in the 2D response maps. Conclusions: The obtained results demonstrate the high reproducibility of the MD fabrication process. The observed discrepancies among the output correction factors reported by several authors for MD response in very small fields are very unlikely to be ascribed to unintentional variations of the device active surface area and volume. It is the opinion of the authors that the role of the volume averaging as well as of other perturbation effects should be separately investigated instead, both experimentally and by Monte Carlo simulations, in order to better clarify the behaviour of the MD response in very small fields.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vlad, Roxana M.; Kolios, Michael C.; Moseley, Joanne L.
Purpose: High frequency ultrasound imaging, 10-30 MHz, has the capability to assess tumor response to radiotherapy in mouse tumors as early as 24 h after treatment administration. The advantage of this technique is that the image contrast is generated by changes in the physical properties of dying cells. Therefore, a subject can be imaged before and multiple times during the treatment without the requirement of injecting specialized contrast agents. This study is motivated by a need to provide metrics of comparison between the volume and localization of cell death, assessed from histology, with the volume and localization of cell deathmore » surrogate, assessed as regions with increased echogeneity from ultrasound images. Methods: The mice were exposed to radiation doses of 2, 4, and 8 Gy. Ultrasound images were collected from each tumor before and 24 h after exposure to radiation using a broadband 25 MHz center frequency transducer. After radiotherapy, tumors exhibited hyperechoic regions in ultrasound images that corresponded to areas of cell death in histology. The ultrasound and histological images were rigidly registered. The tumors and regions of cell death were manually outlined on histological images. Similarly, the tumors and hyperechoic regions were outlined on the ultrasound images. Each set of contours was converted to a volumetric mesh in order to compare the volumes and the localization of cell death in histological and ultrasound images. Results: A shrinkage factor of 17{+-}2% was calculated from the difference in the tumor volumes evaluated from histological and ultrasound images. This was used to correct the tumor and cell death volumes assessed from histology. After this correction, the average absolute difference between the volume of cell death assessed from ultrasound and histological images was 11{+-}14% and the volume overlap was 70{+-}12%. Conclusions: The method provided metrics of comparison between the volume of cell death assessed from histology and that assessed from ultrasound images. It was applied here to evaluate the capability of ultrasound imaging to assess early tumor response to radiotherapy in mouse tumors. Similarly, it can be applied in the future to evaluate the capability of ultrasound imaging to assess early tumor response to other modalities of cancer treatment. The study contributes to an understanding of the capabilities and limitation of ultrasound imaging at noninvasively detecting cell death. This provides a foundation for future developments regarding the use of ultrasound in preclinical and clinical applications to adapt treatments based on tumor response to cancer therapy.« less
Recurrent major depression and right hippocampal volume: A bivariate linkage and association study.
Mathias, Samuel R; Knowles, Emma E M; Kent, Jack W; McKay, D Reese; Curran, Joanne E; de Almeida, Marcio A A; Dyer, Thomas D; Göring, Harald H H; Olvera, Rene L; Duggirala, Ravi; Fox, Peter T; Almasy, Laura; Blangero, John; Glahn, David C
2016-01-01
Previous work has shown that the hippocampus is smaller in the brains of individuals suffering from major depressive disorder (MDD) than those of healthy controls. Moreover, right hippocampal volume specifically has been found to predict the probability of subsequent depressive episodes. This study explored the utility of right hippocampal volume as an endophenotype of recurrent MDD (rMDD). We observed a significant genetic correlation between the two traits in a large sample of Mexican American individuals from extended pedigrees (ρg = -0.34, p = 0.013). A bivariate linkage scan revealed a significant pleiotropic quantitative trait locus on chromosome 18p11.31-32 (LOD = 3.61). Bivariate association analysis conducted under the linkage peak revealed a variant (rs574972) within an intron of the gene SMCHD1 meeting the corrected significance level (χ(2) = 19.0, p = 7.4 × 10(-5)). Univariate association analyses of each phenotype separately revealed that the same variant was significant for right hippocampal volume alone, and also revealed a suggestively significant variant (rs12455524) within the gene DLGAP1 for rMDD alone. The results implicate right-hemisphere hippocampal volume as a possible endophenotype of rMDD, and in so doing highlight a potential gene of interest for rMDD risk. © 2015 Wiley Periodicals, Inc.
Wang, Chunrong; Ding, Yanhui; Shen, Bixian; Gao, Dehong; An, Jie; Peng, Kewen; Hou, Gangqiang; Zou, Liqiu; Jiang, Mei; Qiu, Shijun
2017-05-01
Gray matter volume deficits have been identified in cognitively impaired patients with chronic obstructive pulmonary disease (COPD). However, it remains unknown whether the gray matter volume is altered in COPD patients with subclinical cognitive impairment. To determine whether any gray matter abnormalities are present in these patients, neuropsychological tests and structural MRI data were analyzed from 60 patients with COPD and 60 age-, gender-, education-, and handedness-matched normal controls (NCs). The COPD patients had similar Mini-Mental State Examination (MMSE) scores compared with the NCs. However, they had reduced Montreal Cognitive Assessment (MoCA) scores for visuospatial and executive and naming and memory functions (P < 0.001). Voxel-based morphometry (VBM) analysis revealed that the COPD patients had significantly lowered gray matter volumes in several brain regions, including the left precuneus (PrCU), bilateral calcarine (CAL), right superior temporal gyrus/middle temporal gyrus (STG/MTG), bilateral fusiform gyrus (FG), and right inferior parietal lobule (IPL) (P < 0.01, corrected). Importantly, the forced vital capacity (FVC) was found to be associated with the gray matter volume in the calcarine. The present study confirmed that brain structural changes were present in stable COPD patients with subclinical cognitive impairment. These findings may provide new insights into the pathogenesis of COPD.
Brain-derived Neurotrophic Factor (BDNF) and gray matter volume in bipolar disorder.
Poletti, S; Aggio, V; Hoogenboezem, T A; Ambrée, O; de Wit, H; Wijkhuijs, A J M; Locatelli, C; Colombo, C; Arolt, V; Drexhage, H A; Benedetti, F
2017-02-01
Bipolar Disorder (BD) is a severe psychiatric condition characterized by grey matter (GM) volumes reduction. Neurotrophic factors have been suggested to play a role in the neuroprogressive changes during the illness course. In particular peripheral brain-derived neurotrophic factor (BDNF) has been proposed as a potential biomarker related to disease activity and neuroprogression in BD. The aim of our study was to investigate if serum levels of BDNF are associated with GM volumes in BD patients and healthy controls (HC). We studied 36 inpatients affected by a major depressive episode in course of BD type I and 17 HC. Analysis of variance was performed to investigate the effect of diagnosis on GM volumes in the whole brain. Threshold for significance was P<0.05, Family Wise Error (FWE) corrected for multiple comparisons. All the analyses were controlled for the effect of nuisance covariates known to influence GM volumes, such as age, gender and lithium treatment. BD patients showed significantly higher serum BDNF levels compared with HC. Reduced GM volumes in BD patients compared to HC were observed in several brain areas, encompassing the caudate head, superior temporal gyrus, insula, fusiform gyrus, parahippocampal gyrus, and anterior cingulate cortex. The interaction analysis between BDNF levels and diagnosis showed a significant effect in the middle frontal gyrus. HC reported higher BDNF levels associated with higher GM volumes, whereas no association between BDNF and GM volumes was observed in BD. Our study seems to suggest that although the production of BDNF is increased in BD possibly to prevent and repair neural damage, its effects could be hampered by underlying neuroinflammatory processes interfering with the neurodevelopmental role of BDNF. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Fuin, Niccolo; Catalano, Onofrio Antonio; Scipioni, Michele; Canjels, Lisanne P W; Izquierdo, David; Pedemonte, Stefano; Catana, Ciprian
2018-01-25
Purpose: We present an approach for concurrent reconstruction of respiratory motion compensated abdominal DCE-MRI and PET data in an integrated PET/MR scanner. The MR and PET reconstructions share the same motion vector fields (MVFs) derived from radial MR data; the approach is robust to changes in respiratory pattern and do not increase the total acquisition time. Methods: PET and DCE-MRI data of 12 oncological patients were simultaneously acquired for 6 minutes on an integrated PET/MR system after administration of 18 F-FDG and gadoterate meglumine. Golden-angle radial MR data were continuously acquired simultaneously with PET data and sorted into multiple motion phases based on a respiratory signal derived directly from the radial MR data. The resulting multidimensional dataset was reconstructed using a compressed sensing approach that exploits sparsity among respiratory phases. MVFs obtained using the full 6-minute (MC_6-min) and only the last 1 minute (MC_1-min) of data were incorporated into the PET reconstruction to obtain motion-corrected PET images and in an MR iterative reconstruction algorithm to produce a series of motion-corrected DCE-MRI images (moco_GRASP). The motion-correction methods (MC_6-min and MC_1-min) were evaluated by qualitative analysis of the MR images and quantitative analysis of maximum and mean standardized uptake values (SUV max , SUVmean), contrast, signal-to-noise ratio (SNR) and lesion volume in the PET images. Results: Motion corrected MC_6-min PET images demonstrated 30%, 23%, 34% and 18% increases in average SUV max , SUVmean, contrast and SNR, and an average 40% reduction in lesion volume with respect to the non-motion-corrected PET images. The changes in these figures of merit were smaller but still substantial for the MC_1-min protocol: 19%, 10%, 15% and 9% increases in average SUV max , SUVmean, contrast and SNR; and a 28% reduction in lesion volume. Moco_GRASP images were deemed of acceptable or better diagnostic image quality with respect to conventional breath hold cartesian VIBE acquisitions. Conclusion: We presented a method that allows the simultaneous acquisition of respiratory motion-corrected diagnostic quality DCE-MRI and quantitatively accurate PET data in an integrated PET/MR scanner with negligible prolongation in acquisition time compared to routine PET/DCE-MRI protocols. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Hanlon, Colleen A.; Owens, Max M.; Joseph, Jane E.; Zhu, Xun; George, Mark S.; Brady, Kathleen T.; Hartwell, Karen J.
2014-01-01
Although established adult smokers with long histories of nicotine dependence have lower neural tissue volume than non-smokers, it is not clear if lower regional brain volume is also observed in younger, less established smokers. The primary goal of this study was to investigate neural tissue volume in a large group of smokers and non-smokers, with a secondary goal of measuring the impact of age on these effects. We used voxel-based morphometry to compare regional gray matter volume in 118 individuals (59 smokers, 59 age- and gender-matched non-smokers). Younger smokers had significantly lower gray matter volume in the left thalamus and the left amygdala than their non-smoking peers (family-wise error-corrected clusters, P < 0.05). There was no correlation between smoking use variables and tissue volume among younger smokers. Established smokers had significantly lower gray matter volume than age-matched non-smokers in the insula, parahippocampal gyrus and pallidum. Medial prefrontal cortex gray matter volume was negatively correlated with pack-years of smoking among the established smokers, but not the younger smokers. These data reveal that regional tissue volume differences are not limited exclusively to established smokers. Deficits in young adults indicate that cigarette smoking may either be deleterious to the thalamus and amygdala at an earlier age than previously reported, or that pre-existing differences in these areas may predispose individuals to the development of nicotine dependence. PMID:25125263
Freudlsperger, Christian; Steinmacher, Sahra; Bächli, Heidi; Somlo, Elek; Hoffmann, Jürgen; Engel, Michael
2015-06-01
There is still disagreement regarding the intracranial volumes of patients with metopic synostosis compared with healthy patients. This study aimed to compare the intracranial volume of children with metopic synostosis before and after surgery to an age- and sex-matched control cohort using three-dimensional (3D) photogrammetry. Eighteen boys with metopic synostosis were operated on using standardized fronto-orbital advancement. Frontal, posterior and total intracranial volumes were measured exactly 1 day pre-operatively and 10 days post-operatively, using 3D photogrammetry. To establish an age- and sex-matched control group, the 3D photogrammetric data of 634 healthy boys between the ages of 3 and 13 months were analyzed. Mean age at surgery was 9 months (SD 1.7). Prior to surgery, boys with metopic synostosis showed significantly reduced frontal and total intracranial volumes compared with the reference group, but similar posterior volumes. After surgery, frontal and total intracranial volumes did not differ statistically from the control group. As children with metopic synostosis showed significantly smaller frontal and total intracranial volumes compared with an age- and sex-matched control group, corrective surgery should aim to achieve volume expansion. Furthermore, 3D photogrammetry provides a valuable alternative to CT scans in the measurement of intracranial volume in children with metopic synostosis, which significantly reduces the amount of radiation exposure to the growing brain. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Re-evaluation of the correction factors for the GROVEX
NASA Astrophysics Data System (ADS)
Ketelhut, Steffen; Meier, Markus
2018-04-01
The GROVEX (GROssVolumige EXtrapolationskammer, large-volume extrapolation chamber) is the primary standard for the dosimetry of low-dose-rate interstitial brachytherapy at the Physikalisch-Technische Bundesanstalt (PTB). In the course of setup modifications and re-measuring of several dimensions, the correction factors have been re-evaluated in this work. The correction factors for scatter and attenuation have been recalculated using the Monte Carlo software package EGSnrc, and a new expression has been found for the divergence correction. The obtained results decrease the measured reference air kerma rate by approximately 0.9% for the representative example of a seed of type Bebig I25.S16C. This lies within the expanded uncertainty (k = 2).
Examination of simplified travel demand model. [Internal volume forecasting model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, R.L. Jr.; McFarlane, W.J.
1978-01-01
A simplified travel demand model, the Internal Volume Forecasting (IVF) model, proposed by Low in 1972 is evaluated as an alternative to the conventional urban travel demand modeling process. The calibration of the IVF model for a county-level study area in Central Wisconsin results in what appears to be a reasonable model; however, analysis of the structure of the model reveals two primary mis-specifications. Correction of the mis-specifications leads to a simplified gravity model version of the conventional urban travel demand models. Application of the original IVF model to ''forecast'' 1960 traffic volumes based on the model calibrated for 1970more » produces accurate estimates. Shortcut and ad hoc models may appear to provide reasonable results in both the base and horizon years; however, as shown by the IVF mode, such models will not always provide a reliable basis for transportation planning and investment decisions.« less
Ansell, Emily B; Rando, Kenneth; Tuit, Keri; Guarnaccia, Joseph; Sinha, Rajita
2012-07-01
Cumulative adversity and stress are associated with risk of psychiatric disorders. While basic science studies show repeated and chronic stress effects on prefrontal and limbic neurons, human studies examining cumulative stress and effects on brain morphology are rare. Thus, we assessed whether cumulative adversity is associated with differences in gray matter volume, particularly in regions regulating emotion, self-control, and top-down processing in a community sample. One hundred three healthy community participants, aged 18 to 48 and 68% male, completed interview assessment of cumulative adversity and a structural magnetic resonance imaging protocol. Whole-brain voxel-based-morphometry analysis was performed adjusting for age, gender, and total intracranial volume. Cumulative adversity was associated with smaller volume in medial prefrontal cortex (PFC), insular cortex, and subgenual anterior cingulate regions (familywise error corrected, p < .001). Recent stressful life events were associated with smaller volume in two clusters: the medial PFC and the right insula. Life trauma was associated with smaller volume in the medial PFC, anterior cingulate, and subgenual regions. The interaction of greater subjective chronic stress and greater cumulative life events was associated with smaller volume in the orbitofrontal cortex, insula, and anterior and subgenual cingulate regions. Current results demonstrate that increasing cumulative exposure to adverse life events is associated with smaller gray matter volume in key prefrontal and limbic regions involved in stress, emotion and reward regulation, and impulse control. These differences found in community participants may serve to mediate vulnerability to depression, addiction, and other stress-related psychopathology. Copyright © 2012 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.
Ansell, Emily B.; Rando, Kenneth; Tuit, Keri; Guarnaccia, Joseph; Sinha, Rajita
2012-01-01
Background Cumulative adversity and stress are associated with risk of psychiatric disorders. While basic science studies show repeated and chronic stress effects on prefrontal and limbic neurons, human studies examining cumulative stress and effects on brain morphology are rare. Thus, we assessed whether cumulative adversity is associated with differences in gray matter volume, particularly in regions regulating emotion, self-control, and top-down processing in a community sample. Methods One hundred three healthy community participants, aged 18 to 48 and 68% male, completed interview assessment of cumulative adversity and a structural magnetic resonance imaging protocol. Whole-brain voxel-based-morphometry analysis was performed adjusting for age, gender, and total intracranial volume. Results Cumulative adversity was associated with smaller volume in medial prefrontal cortex (PFC), insular cortex, and subgenual anterior cingulate regions (familywise error corrected, p <.001). Recent stressful life events were associated with smaller volume in two clusters: the medial PFC and the right insula. Life trauma was associated with smaller volume in the medial PFC, anterior cingulate, and subgenual regions. The interaction of greater subjective chronic stress and greater cumulative life events was associated with smaller volume in the orbitofrontal cortex, insula, and anterior and subgenual cingulate regions. Conclusions Current results demonstrate that increasing cumulative exposure to adverse life events is associated with smaller gray matter volume in key prefrontal and limbic regions involved in stress, emotion and reward regulation, and impulse control. These differences found in community participants may serve to mediate vulnerability to depression, addiction, and other stress-related psychopathology. PMID:22218286
Echocardiographic chamber quantification in a healthy Dutch population.
van Grootel, R W J; Menting, M E; McGhie, J; Roos-Hesselink, J W; van den Bosch, A E
2017-12-01
For accurate interpretation of echocardiographic measurements normative data are required, which are provided by guidelines. For this article, the hypothesis was that these cannot be extrapolated to the Dutch population, since in Dutch clinical practice often higher values are found, which may not be pathological but physiological. Therefore this study aimed to 1) obtain and propose normative values for cardiac chamber quantification in a healthy Dutch population and 2) determine influences of baseline characteristics on these measurements. Prospectively recruited healthy subjects, aged 20-72 years (at least 28 subjects per age decade, equally distributed for gender) underwent physical examination and 2D and 3D echocardiography. Both ventricles and atria were assessed and volumes were calculated. 147 subjects were included (age 44 ± 14 years, 50% female). Overall, feasibility was good for both linear and volumetric measurements. Linear and volumetric parameters were consistently higher than current guidelines recommend, while functional parameters were in line with the guidelines. This was more so in the older population. 3D volumes were higher than 2D volumes. Gender dependency was seen in all body surface area (BSA) corrected volumes and with increasing age, ejection fractions decreased. This study provides 2D and 3D echocardiographic reference ranges for both ventricles and atria derived from a healthy Dutch population. BSA indexed volumes are gender-dependent, age did not influence ventricular volumes and a rise in blood pressure was independently associated with increased right ventricular volumes. The higher volumes found may be indicative for the Dutch population being the tallest in the world.
Atypical nucleus accumbens morphology in psychopathy: another limbic piece in the puzzle.
Boccardi, Marina; Bocchetta, Martina; Aronen, Hannu J; Repo-Tiihonen, Eila; Vaurio, Olli; Thompson, Paul M; Tiihonen, Jari; Frisoni, Giovanni B
2013-01-01
Psychopathy has been associated with increased putamen and striatum volumes. The nucleus accumbens - a key structure in reversal learning, less effective in psychopathy - has not yet received specific attention. Moreover, basal ganglia morphology has never been explored. We examined the morphology of the caudate, putamen and accumbens, manually segmented from magnetic resonance images of 26 offenders (age: 32.5 ± 8.4) with medium-high psychopathy (mean PCL-R=30 ± 5) and 25 healthy controls (age: 34.6 ± 10.8). Local differences were statistically modeled using a surface-based radial distance mapping method (p<0.05; multiple comparisons correction through permutation tests). In psychopathy, the caudate and putamen had normal global volume, but different morphology, significant after correction for multiple comparisons, for the right dorsal putamen (permutation test: p=0.02). The volume of the nucleus accumbens was 13% smaller in psychopathy (p corrected for multiple comparisons <0.006). The atypical morphology consisted of predominant anterior hypotrophy bilaterally (10-30%). Caudate and putamen local morphology displayed negative correlation with the lifestyle factor of the PCL-R (permutation test: p=0.05 and 0.03). From these data, psychopathy appears to be associated with an atypical striatal morphology, with highly significant global and local differences of the accumbens. This is consistent with the clinical syndrome and with theories of limbic involvement. Copyright © 2013 Elsevier Ltd. All rights reserved.
Daisne, Jean-François; Blumhofer, Andreas
2013-06-26
Intensity modulated radiotherapy for head and neck cancer necessitates accurate definition of organs at risk (OAR) and clinical target volumes (CTV). This crucial step is time consuming and prone to inter- and intra-observer variations. Automatic segmentation by atlas deformable registration may help to reduce time and variations. We aim to test a new commercial atlas algorithm for automatic segmentation of OAR and CTV in both ideal and clinical conditions. The updated Brainlab automatic head and neck atlas segmentation was tested on 20 patients: 10 cN0-stages (ideal population) and 10 unselected N-stages (clinical population). Following manual delineation of OAR and CTV, automatic segmentation of the same set of structures was performed and afterwards manually corrected. Dice Similarity Coefficient (DSC), Average Surface Distance (ASD) and Maximal Surface Distance (MSD) were calculated for "manual to automatic" and "manual to corrected" volumes comparisons. In both groups, automatic segmentation saved about 40% of the corresponding manual segmentation time. This effect was more pronounced for OAR than for CTV. The edition of the automatically obtained contours significantly improved DSC, ASD and MSD. Large distortions of normal anatomy or lack of iodine contrast were the limiting factors. The updated Brainlab atlas-based automatic segmentation tool for head and neck Cancer patients is timesaving but still necessitates review and corrections by an expert.
Possin, Katherine L; Chester, Serana K; Laluz, Victor; Bostrom, Alan; Rosen, Howard J; Miller, Bruce L; Kramer, Joel H
2012-09-01
On tests of design fluency, an examinee draws as many different designs as possible in a specified time limit while avoiding repetition. The neuroanatomical substrates and diagnostic group differences of design fluency repetition errors and total correct scores were examined in 110 individuals diagnosed with dementia, 53 with mild cognitive impairment (MCI), and 37 neurologically healthy controls. The errors correlated significantly with volumes in the right and left orbitofrontal cortex (OFC), the right and left superior frontal gyrus, the right inferior frontal gyrus, and the right striatum, but did not correlate with volumes in any parietal or temporal lobe regions. Regression analyses indicated that the lateral OFC may be particularly crucial for preventing these errors, even after excluding patients with behavioral variant frontotemporal dementia (bvFTD) from the analysis. Total correct correlated more diffusely with volumes in the right and left frontal and parietal cortex, the right temporal cortex, and the right striatum and thalamus. Patients diagnosed with bvFTD made significantly more repetition errors than patients diagnosed with MCI, Alzheimer's disease, semantic dementia, progressive supranuclear palsy, or corticobasal syndrome. In contrast, total correct design scores did not differentiate the dementia patients. These results highlight the frontal-anatomic specificity of design fluency repetitions. In addition, the results indicate that the propensity to make these errors supports the diagnosis of bvFTD. (JINS, 2012, 18, 1-11).
Inferior Pedicle Autoaugmentation Mastopexy After Breast Implant Removal
Frey, Hans Peter; Hasse, Frank Michael; Hasselberg, Jens
2010-01-01
Background A new method of autoaugmentation mammaplasty is presented to correct ptosis and to increase the projection and volume of the breast in patients who would like a reposition augmentation mammaplasty after breast implant removal but do not want a new implant. Methods Between 1999 and 2007, a total of 27 patients (age = 54 ± 7.3 years) underwent mammaplasty using an inferior-based flap of deepithelialized subcutaneous and breast tissue modularized to its pedicle which was inserted beneath a superior pedicle used for correction of ptosis and to increase the projection and apparent volume of the breast. Results The results confirmed that autoaugmentation mammaplasty of the breast following removal of the implant yields longstanding results. It corrects ptosis and increases the projection and apparent volume of the breast when mastopexy is planned without use of a new implant. Twelve months after surgery the degree of descent of the inframammary fold generally parallels that of the nipple. The mean level of the inframammary fold was below the mean level of the nipple. Postoperatively, the optimum distance had been largely achieved. Conclusion The advantages of the technique presented here are that it minimizes the skin scar in cases using vertical mammaplasty techniques and optimizes the breast shape after breast implant removal in patients who do not want a new implant. PMID:20174800
Partial Molar Volumes of Aqua Ions from First Principles.
Wiktor, Julia; Bruneval, Fabien; Pasquarello, Alfredo
2017-08-08
Partial molar volumes of ions in water solution are calculated through pressures obtained from ab initio molecular dynamics simulations. The correct definition of pressure in charged systems subject to periodic boundary conditions requires access to the variation of the electrostatic potential upon a change of volume. We develop a scheme for calculating such a variation in liquid systems by setting up an interface between regions of different density. This also allows us to determine the absolute deformation potentials for the band edges of liquid water. With the properly defined pressures, we obtain partial molar volumes of a series of aqua ions in very good agreement with experimental values.
Medrano-Gracia, Pau; Cowan, Brett R; Bluemke, David A; Finn, J Paul; Kadish, Alan H; Lee, Daniel C; Lima, Joao A C; Suinesiaputra, Avan; Young, Alistair A
2013-09-13
Cardiovascular imaging studies generate a wealth of data which is typically used only for individual study endpoints. By pooling data from multiple sources, quantitative comparisons can be made of regional wall motion abnormalities between different cohorts, enabling reuse of valuable data. Atlas-based analysis provides precise quantification of shape and motion differences between disease groups and normal subjects. However, subtle shape differences may arise due to differences in imaging protocol between studies. A mathematical model describing regional wall motion and shape was used to establish a coordinate system registered to the cardiac anatomy. The atlas was applied to data contributed to the Cardiac Atlas Project from two independent studies which used different imaging protocols: steady state free precession (SSFP) and gradient recalled echo (GRE) cardiovascular magnetic resonance (CMR). Shape bias due to imaging protocol was corrected using an atlas-based transformation which was generated from a set of 46 volunteers who were imaged with both protocols. Shape bias between GRE and SSFP was regionally variable, and was effectively removed using the atlas-based transformation. Global mass and volume bias was also corrected by this method. Regional shape differences between cohorts were more statistically significant after removing regional artifacts due to imaging protocol bias. Bias arising from imaging protocol can be both global and regional in nature, and is effectively corrected using an atlas-based transformation, enabling direct comparison of regional wall motion abnormalities between cohorts acquired in separate studies.
The Coast Artillery Journal. Volume 72, Number 3, March 1930
1930-03-01
computation of the score. A careful study of these instructions is necessary in order that the score be correctly computed. The quantities substituted...components: A , B, C, D; the score for a practice is A +B+C- D. D, the penalty co.mpo.nent,is always subtracted. Band C alsoma:r, in extreme cases ,be... studying the subject, and ’Ourown Navy will have a receiving set in every airplane and a two-wayset in each commandplane. In addition to ather
Left Atrium Size in Elite Athletes.
Iskandar, Aline; Mujtaba, Mohammad Tokir; Thompson, Paul D
2015-07-01
The goal of this study was to perform a meta-analysis of the published literature to investigate the relationship of high levels of exercise training to left atrial (LA) size. The "athlete's heart" is a series of cardiac adaptations to systematic exercise training and may include LA enlargement. We conducted a systematic review of English-language studies in MEDLINE and Scopus from inception through April 29, 2014, that reported LA size in elite athletes. A total of 54 studies comprising 7,189 elite athletes and 1,375 controls were included. Forty-eight of the 54 studies reported absolute LA diameter in 7,018 athletes and 1,044 controls. Nine of the 54 studies (including 992 athletes and 426 controls) presented LA volume corrected for body surface area. The adjusted weighted mean LA diameter was 4.1 mm greater in athletes overall compared with sedentary controls (p < 0.0001), and LA volume index was 7.0 ml/m(2) greater in athletes than controls (p < 0.01). Compared with controls, LA diameter was 4.6 mm greater in endurance-trained athletes (p < 0.0001), 2.9 mm greater in strength-trained athletes (p < 0.03), 3.5 mm greater in combined strength- and endurance-trained athletes (p < 0.0001), and 4.2 mm greater in athletes with unspecified training (p < 0.02). To our knowledge, this is the largest compilation of studies documenting that elite athletes have larger LA dimensions compared with controls when evaluated by either LA diameter or LA volume corrected for body surface area. The largest average LA diameters were reported in endurance athletes. Physicians evaluating athletes should be aware that the LA is increased in both strength- and endurance-trained elite athletes. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Erratum: Erratum to Central European Journal of Engineering, Volume 4, Issue 1
NASA Astrophysics Data System (ADS)
Kumar, M. Ajay; Srikanth, N. V.
2014-06-01
Paper by M. Ajay Kumar, N. V. Srikanth, et al. "An adaptive neuro fuzzy inference system controlled space cector pulse width modulation based HVDC light transmission system under AC fault conditions" in Volume 4, Issue 1, 27-38/March 2014 doi: 10.2478/s13531-013-0143-4 contains an error in the title. The correct title is presented below
NASA Technical Reports Server (NTRS)
Hooker, Stanford B. (Editor); Acker, James G. (Editor); Firestone, Elaine R. (Editor); Mcclain, Charles R.; Fraser, Robert S.; Mclean, James T.; Darzi, Michael; Firestone, James K.; Patt, Frederick S.; Schieber, Brian D.
1994-01-01
This document provides brief reports, or case studies, on a number of investigations and data set development activities sponsored by the Calibration and Validation Team (CVT) within the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Project. Chapter 1 is a comparison with the atmospheric correction of Coastal Zone Color Scanner (CZCS) data using two independent radiative transfer formulations. Chapter 2 is a study on lunar reflectance at the SeaWiFS wavelengths which was useful in establishing the SeaWiFS lunar gain. Chapter 3 reports the results of the first ground-based solar calibration of the SeaWiFS instrument. The experiment was repeated in the fall of 1993 after the instrument was modified to reduce stray light; the results from the second experiment will be provided in the next case studies volume. Chapter 4 is a laboratory experiment using trap detectors which may be useful tools in the calibration round-robin program. Chapter 5 is the original data format evaluation study conducted in 1992 which outlines the technical criteria used in considering three candidate formats, the hierarchical data format (HDF), the common data format (CDF), and the network CDF (netCDF). Chapter 6 summarizes the meteorological data sets accumulated during the first three years of CZCS operation which are being used for initial testing of the operational SeaWiFS algorithms and systems and would be used during a second global processing of the CZCS data set. Chapter 7 describes how near-real time surface meteorological and total ozone data required for the atmospheric correction algorithm will be retrieved and processed. Finally, Chapter 8 is a comparison of surface wind products from various operational meteorological centers and field observations. Surface winds are used in the atmospheric correction scheme to estimate glint and foam radiances.
van Veelen, Marie-Lise C; Jippes, Marielle; Carolina, Julius-Carl A; de Rooi, Johan; Dirven, Clemens M F; van Adrichem, Leon N A; Mathijssen, Irene M
2016-10-01
Surgery for sagittal synostosis aims at correction of skull shape and restoration of growth potential. Small cranial volume is associated with raised intracranial pressure (ICP). Although many techniques have been described, information on postoperative volume related to early and late remodeling is lacking. Between 2004 and 2008, a total of 95 patients were collected who underwent either early extended strip craniectomy or late total cranial remodeling according to age of presentation. Volume was measured on three-dimensional (3D) photogrammetry. Volume measurements were related to cranial index (CI), head circumference (HCsd), and signs of raised ICP. In a small subset of patients, volume measurements on 3D photogrammetry were assessed for inter- and intrarater reliability and compared to 3D computed tomography (CT). Volume was increased in all patients before and after surgery compared to normative values. Postoperatively, late total cranial remodeling resulted in a slightly larger volume than early extended strip craniectomy. Volume measurements showed a good correlation with HCsd (0.67) and a poor relationship with CI (0.13). Headache occurred more frequently in patients with a lower cranial volume. Although papilledema and reoperation showed the same trend, the numbers were too small for statistical analysis. Reproducibility of volume measurements on 3D photogrammetry was high, as was the correlation with measurements on CT. Late total cranial remodeling results in a larger postoperative volume, as measured on 3D photogrammetry, than extended strip craniectomy. Clinical signs of raised ICP occur more frequently in patients with a smaller volume. To measure volume, 3D photogrammetry is a good alternative to CT. Copyright © 2016. Published by Elsevier Ltd.
von Marchtaler, Philipp V; Weller, Julia M; Kruse, Friedrich E; Tourtas, Theofilos
2018-01-01
To perform a fellow eye comparison of outcomes and complications when using air or sulfur hexafluoride (SF6) gas as a tamponade in Descemet membrane endothelial keratoplasty (DMEK). One hundred thirty-six eyes of 68 consecutive patients who underwent uneventful DMEK in both eyes for Fuchs endothelial corneal dystrophy were included in this retrospective study. Inclusion criteria were air tamponade (80% of the anterior chamber volume) in the first eye and 20% SF6 gas tamponade (80% of the anterior chamber volume) in the second eye; and same donor tissue culture condition in both eyes. All eyes received laser iridotomy on the day before DMEK. Main outcome measures included preoperative and postoperative best-corrected visual acuity, endothelial cell density, corneal volume, rebubbling rate, and rate of postoperative pupillary block caused by the air/gas bubble. Thirteen of 68 eyes (19.1%) with an air tamponade needed rebubbling compared with 4 of 68 eyes (5.9%) with an SF6 gas tamponade (P = 0.036). Postoperative pupillary block necessitating partial release of air/gas occurred in 1 eye (1.5%) with an air tamponade and 3 eyes (4.4%) with an SF6 gas tamponade (P = 0.301). There were no significant differences in preoperative and postoperative best-corrected visual acuity, endothelial cell density, and corneal volume within 3-month follow-up. Our results confirm the previously reported better graft adhesion when using an SF6 gas tamponade in DMEK without increased endothelial cell toxicity. The rate of pupillary block in eyes with an SF6 gas tamponade was comparable to that with an air tamponade. As a consequence, we recommend using SF6 gas as the tamponade in DMEK.
Refractive Lenticule Implantation for Correction of Ametropia: Case Reports and Literature Review.
Lazaridis, A; Messerschmidt-Roth, A; Sekundo, W; Schulze, S
2017-01-01
The ReLEx® technique allows correction of refractive errors through the creation and extraction of refractive stromal lenticules. Contrary to excimer laser corneal refractive procedures, where the stromal tissue is photoablated, the extracted lenticules obtained with ReLEx® can be preserved. Recent studies and case reports have described autologous re-implantation and allogeneic implantation of refractive lenticules into femtosecond-laser created stromal pockets in order to reverse the refractive outcome of a myopic corneal refractive procedure, correct hyperopia, aphakia, presbyopia and treat keratoconus. The use of stromal lenticules has also been described for therapeutic purposes, with an allogenic lenticule being transplanted under a LASIK flap in order to restore corneal volume and reduce the refractive error in a case of excessive stromal tissue removal after LASIK. This review summarises the results of the latest case reports and studies that describe the implantation of cryopreserved or fresh refractive stromal lenticules and discusses the feasibility, safety and refractive outcomes of the procedure, on the basis of published literature as well as our own experience. Georg Thieme Verlag KG Stuttgart · New York.
Hippeläinen, Eero; Mäkelä, Teemu; Kaasalainen, Touko; Kaleva, Erna
2017-12-01
Developments in single photon emission tomography instrumentation and reconstruction methods present a potential for decreasing acquisition times. One of such recent options for myocardial perfusion imaging (MPI) is IQ-SPECT. This study was motivated by the inconsistency in the reported ejection fraction (EF) and left ventricular (LV) volume results between IQ-SPECT and more conventional low-energy high-resolution (LEHR) collimation protocols. IQ-SPECT and LEHR quantitative results were compared while the equivalent number of iterations (EI) was varied. The end-diastolic (EDV) and end-systolic volumes (ESV) and the derived EF values were investigated. A dynamic heart phantom was used to produce repeatable ESVs, EDVs and EFs. Phantom performance was verified by comparing the set EF values to those measured from a gated multi-slice X-ray computed tomography (CT) scan (EF True ). The phantom with an EF setting of 45, 55, 65 and 70% was imaged with both IQ-SPECT and LEHR protocols. The data were reconstructed with different EI, and two commonly used clinical myocardium delineation software were used to evaluate the LV volumes. The CT verification showed that the phantom EF settings were repeatable and accurate with the EF True being within 1% point from the manufacture's nominal value. Depending on EI both MPI protocols can be made to produce correct EF estimates, but IQ-SPECT protocol produced on average 41 and 42% smaller EDV and ESV when compared to the phantom's volumes, while LEHR protocol underestimated volumes by 24 and 21%, respectively. The volume results were largely similar between the delineation methods used. The reconstruction parameters can greatly affect the volume estimates obtained from perfusion studies. IQ-SPECT produces systematically smaller LV volumes than the conventional LEHR MPI protocol. The volume estimates are also software dependent.
Alpha Air Sample Counting Efficiency Versus Dust Loading: Evaluation of a Large Data Set
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hogue, M. G.; Gause-Lott, S. M.; Owensby, B. N.
Dust loading on air sample filters is known to cause a loss of efficiency for direct counting of alpha activity on the filters, but the amount of dust loading and the correction factor needed to account for attenuated alpha particles is difficult to assess. In this paper, correction factors are developed by statistical analysis of a large database of air sample results for a uranium and plutonium processing facility at the Savannah River Site. As is typically the case, dust-loading data is not directly available, but sample volume is found to be a reasonable proxy measure; the amount of dustmore » loading is inferred by a combination of the derived correction factors and a Monte Carlo model. The technique compares the distribution of activity ratios [beta/(beta + alpha)] by volume and applies a range of correction factors on the raw alpha count rate. The best-fit results with this method are compared with MCNP modeling of activity uniformly deposited in the dust and analytical laboratory results of digested filters. Finally, a linear fit is proposed to evenly-deposited alpha activity collected on filters with dust loading over a range of about 2 mg cm -2 to 1,000 mg cm -2.« less
Alpha Air Sample Counting Efficiency Versus Dust Loading: Evaluation of a Large Data Set
Hogue, M. G.; Gause-Lott, S. M.; Owensby, B. N.; ...
2018-03-03
Dust loading on air sample filters is known to cause a loss of efficiency for direct counting of alpha activity on the filters, but the amount of dust loading and the correction factor needed to account for attenuated alpha particles is difficult to assess. In this paper, correction factors are developed by statistical analysis of a large database of air sample results for a uranium and plutonium processing facility at the Savannah River Site. As is typically the case, dust-loading data is not directly available, but sample volume is found to be a reasonable proxy measure; the amount of dustmore » loading is inferred by a combination of the derived correction factors and a Monte Carlo model. The technique compares the distribution of activity ratios [beta/(beta + alpha)] by volume and applies a range of correction factors on the raw alpha count rate. The best-fit results with this method are compared with MCNP modeling of activity uniformly deposited in the dust and analytical laboratory results of digested filters. Finally, a linear fit is proposed to evenly-deposited alpha activity collected on filters with dust loading over a range of about 2 mg cm -2 to 1,000 mg cm -2.« less
NASA Technical Reports Server (NTRS)
Radakovich, Jon; Bosilovich, M.; Chern, Jiun-dar; daSilva, Arlindo
2004-01-01
The NASA/NCAR Finite Volume GCM (fvGCM) with the NCAR CLM (Community Land Model) version 2.0 was integrated into the NASA/GMAO Finite Volume Data Assimilation System (fvDAS). A new method was developed for coupled skin temperature assimilation and bias correction where the analysis increment and bias correction term is passed into the CLM2 and considered a forcing term in the solution to the energy balance. For our purposes, the fvDAS CLM2 was run at 1 deg. x 1.25 deg. horizontal resolution with 55 vertical levels. We assimilate the ISCCP-DX (30 km resolution) surface temperature product. The atmospheric analysis was performed 6-hourly, while the skin temperature analysis was performed 3-hourly. The bias correction term, which was updated at the analysis times, was added to the skin temperature tendency equation at every timestep. In this presentation, we focus on the validation of the surface energy budget at the in situ reference sites for the Coordinated Enhanced Observation Period (CEOP). We will concentrate on sites that include independent skin temperature measurements and complete energy budget observations for the month of July 2001. In addition, MODIS skin temperature will be used for validation. Several assimilations were conducted and preliminary results will be presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cox, E.F.
1949-03-28
An orifice-manifold systems were used for baro-switch pressure measurements during a bomb drop. The purpose of this report was to show that definite relations exist between manifold volume and correct orifice diameter.
NASA Astrophysics Data System (ADS)
Park, Seyoun; Robinson, Adam; Quon, Harry; Kiess, Ana P.; Shen, Colette; Wong, John; Plishker, William; Shekhar, Raj; Lee, Junghoon
2016-03-01
In this paper, we propose a CT-CBCT registration method to accurately predict the tumor volume change based on daily cone-beam CTs (CBCTs) during radiotherapy. CBCT is commonly used to reduce patient setup error during radiotherapy, but its poor image quality impedes accurate monitoring of anatomical changes. Although physician's contours drawn on the planning CT can be automatically propagated to daily CBCTs by deformable image registration (DIR), artifacts in CBCT often cause undesirable errors. To improve the accuracy of the registration-based segmentation, we developed a DIR method that iteratively corrects CBCT intensities by local histogram matching. Three popular DIR algorithms (B-spline, demons, and optical flow) with the intensity correction were implemented on a graphics processing unit for efficient computation. We evaluated their performances on six head and neck (HN) cancer cases. For each case, four trained scientists manually contoured the nodal gross tumor volume (GTV) on the planning CT and every other fraction CBCTs to which the propagated GTV contours by DIR were compared. The performance was also compared with commercial image registration software based on conventional mutual information (MI), VelocityAI (Varian Medical Systems Inc.). The volume differences (mean±std in cc) between the average of the manual segmentations and automatic segmentations are 3.70+/-2.30 (B-spline), 1.25+/-1.78 (demons), 0.93+/-1.14 (optical flow), and 4.39+/-3.86 (VelocityAI). The proposed method significantly reduced the estimation error by 9% (B-spline), 38% (demons), and 51% (optical flow) over the results using VelocityAI. Although demonstrated only on HN nodal GTVs, the results imply that the proposed method can produce improved segmentation of other critical structures over conventional methods.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oehmigen, Mark, E-mail: mark.oehmigen@uni-due.de
Purpose: This study aims to develop, implement, and evaluate a 16-channel radiofrequency (RF) coil for integrated positron emission tomography/magnetic resonance (PET/MR) imaging of breast cancer. The RF coil is designed for optimized MR imaging performance and PET transparency and attenuation correction (AC) is applied for accurate PET quantification. Methods: A 16-channel breast array RF coil was designed for integrated PET/MR hybrid imaging of breast cancer lesions. The RF coil features a lightweight rigid design and is positioned with a spacer at a defined position on the patient table of an integrated PET/MR system. Attenuation correction is performed by generating andmore » applying a dedicated 3D CT-based template attenuation map. Reposition accuracy of the RF coil on the system patient table while using the positioning frame was tested in repeated measurements using MR-visible markers. The MR, PET, and PET/MR imaging performances were systematically evaluated using modular breast phantoms. Attenuation correction of the RF coil was evaluated with difference measurements of the active breast phantoms filled with radiotracer in the PET detector with and without the RF coil in place, serving as a standard of reference measurement. The overall PET/MR imaging performance and PET quantification accuracy of the new 16-channel RF coil and its AC were then evaluated in first clinical examinations on ten patients with local breast cancer. Results: The RF breast array coil provides excellent signal-to-noise ratio and signal homogeneity across the volume of the breast phantoms in MR imaging and visualizes small structures in the phantoms down to 0.4 mm in plane. Difference measurements with PET revealed a global loss and thus attenuation of counts by 13% (mean value across the whole phantom volume) when the RF coil is placed in the PET detector. Local attenuation ranging from 0% in the middle of the phantoms up to 24% was detected in the peripheral regions of the phantoms at positions closer to attenuating hardware structures of the RF coil. The position accuracy of the RF coil on the patient table when using the positioning frame was determined well below 1 mm for all three spatial dimensions. This ensures perfect position match between the RF coil and its three-dimensional attenuation template during the PET data reconstruction process. When applying the CT-based AC of the RF coil, the global attenuation bias was mostly compensated to ±0.5% across the entire breast imaging volume. The patient study revealed high quality MR, PET, and combined PET/MR imaging of breast cancer. Quantitative activity measurements in all 11 breast cancer lesions of the ten patients resulted in increased mean difference values of SUV{sub max} 11.8% (minimum 3.2%; maximum 23.2%) between nonAC images and images when AC of the RF breast coil was applied. This supports the quantitative results of the phantom study as well as successful attenuation correction of the RF coil. Conclusions: A 16-channel breast RF coil was designed for optimized MR imaging performance and PET transparency and was successfully integrated with its dedicated attenuation correction template into a whole-body PET/MR system. Systematic PET/MR imaging evaluation with phantoms and an initial study on patients with breast cancer provided excellent MR and PET image quality and accurate PET quantification.« less
Mato Abad, Virginia; Quirós, Alicia; García-Álvarez, Roberto; Loureiro, Javier Pereira; Alvarez-Linera, Juan; Frank, Ana; Hernández-Tamames, Juan Antonio
2014-01-01
1H-MRS variability increases due to normal aging and also as a result of atrophy in grey and white matter caused by neurodegeneration. In this work, an automatic process was developed to integrate data from spectra and high-resolution anatomical images to quantify metabolites, taking into account tissue partial volumes within the voxel of interest avoiding additional spectra acquisitions required for partial volume correction. To evaluate this method, we use a cohort of 135 subjects (47 male and 88 female, aged between 57 and 99 years) classified into 4 groups: 38 healthy participants, 20 amnesic mild cognitive impairment patients, 22 multi-domain mild cognitive impairment patients, and 55 Alzheimer's disease patients. Our findings suggest that knowing the voxel composition of white and grey matter and cerebrospinal fluid is necessary to avoid partial volume variations in a single-voxel study and to decrease part of the variability found in metabolites quantification, particularly in those studies involving elder patients and neurodegenerative diseases. The proposed method facilitates the use of 1H-MRS techniques in statistical studies in Alzheimer's disease, because it provides more accurate quantitative measurements, reduces the inter-subject variability, and improves statistical results when performing group comparisons.
Strauss, Rupert W; Muñoz, Beatriz; Wolfson, Yulia; Sophie, Raafay; Fletcher, Emily; Bittencourt, Millena G; Scholl, Hendrik P N
2016-01-01
Aims To estimate disease progression based on analysis of macular volume measured by spectral-domain optical coherence tomography (SD-OCT) in patients affected by Stargardt macular dystrophy (STGD1) and to evaluate the influence of software errors on these measurements. Methods 58 eyes of 29 STGD1 patients were included. Numbers and types of algorithm errors were recorded and manually corrected. In a subgroup of 36 eyes of 18 patients with at least two examinations over time, total macular volume (TMV) and volumes of all nine Early Treatment of Diabetic Retinopathy Study (ETDRS) subfields were obtained. Random effects models were used to estimate the rate of change per year for the population, and empirical Bayes slopes were used to estimate yearly decline in TMV for individual eyes. Results 6958 single B-scans from 190 macular cube scans were analysed. 2360 (33.9%) showed algorithm errors. Mean observation period for follow-up data was 15 months (range 3–40). The median (IQR) change in TMV using the empirical Bayes estimates for the individual eyes was −0.103 (−0.145, −0.059) mm3 per year. The mean (±SD) TMV was 6.321±1.000 mm3 at baseline, and rate of decline was −0.118 mm3 per year (p=0.003). Yearly mean volume change was −0.004 mm3 in the central subfield (mean baseline=0.128 mm3), −0.032 mm3 in the inner (mean baseline=1.484 mm3) and −0.079 mm3 in the outer ETDRS subfields (mean baseline=5.206 mm3). Conclusions SD-OCT measurements allow monitoring the decline in retinal volume in STGD1; however, they require significant manual correction of software errors. PMID:26568636
Keihaninejad, Shiva; Heckemann, Rolf A.; Gousias, Ioannis S.; Hajnal, Joseph V.; Duncan, John S.; Aljabar, Paul; Rueckert, Daniel; Hammers, Alexander
2012-01-01
Brain images contain information suitable for automatically sorting subjects into categories such as healthy controls and patients. We sought to identify morphometric criteria for distinguishing controls (n = 28) from patients with unilateral temporal lobe epilepsy (TLE), 60 with and 20 without hippocampal atrophy (TLE-HA and TLE-N, respectively), and for determining the presumed side of seizure onset. The framework employs multi-atlas segmentation to estimate the volumes of 83 brain structures. A kernel-based separability criterion was then used to identify structures whose volumes discriminate between the groups. Next, we applied support vector machines (SVM) to the selected set for classification on the basis of volumes. We also computed pairwise similarities between all subjects and used spectral analysis to convert these into per-subject features. SVM was again applied to these feature data. After training on a subgroup, all TLE-HA patients were correctly distinguished from controls, achieving an accuracy of 96 ± 2% in both classification schemes. For TLE-N patients, the accuracy was 86 ± 2% based on structural volumes and 91 ± 3% using spectral analysis. Structures discriminating between patients and controls were mainly localized ipsilaterally to the presumed seizure focus. For the TLE-HA group, they were mainly in the temporal lobe; for the TLE-N group they included orbitofrontal regions, as well as the ipsilateral substantia nigra. Correct lateralization of the presumed seizure onset zone was achieved using hippocampi and parahippocampal gyri in all TLE-HA patients using either classification scheme; in the TLE-N patients, lateralization was accurate based on structural volumes in 86 ± 4%, and in 94 ± 4% with the spectral analysis approach. Unilateral TLE has imaging features that can be identified automatically, even when they are invisible to human experts. Such morphometric image features may serve as classification and lateralization criteria. The technique also detects unsuspected distinguishing features like the substantia nigra, warranting further study. PMID:22523539
NASA Astrophysics Data System (ADS)
Hink, R.
2015-09-01
The choice of materials for rocket chamber walls is limited by its thermal resistance. The thermal loads can be reduced substantially by the blowing out of gases through a porous surface. The k- ω-based turbulence models for computational fluid dynamic simulations are designed for smooth, non-permeable walls and have to be adjusted to account for the influence of injected fluids. Wilcox proposed therefore an extension for the k- ω turbulence model for the correct prediction of turbulent boundary layer velocity profiles. In this study, this extension is validated against experimental thermal boundary layer data from the Thermosciences Division of the Department of Mechanical Engineering from the Stanford University. All simulations are performed with a finite volume-based in-house code of the German Aerospace Center. Several simulations with different blowing settings were conducted and discussed in comparison to the results of the original model and in comparison to an additional roughness implementation. This study has permitted to understand that velocity profile corrections are necessary in contrast to additional roughness corrections to predict the correct thermal boundary layer profile of effusive cooled walls. Finally, this approach is applied to a two-dimensional simulation of an effusive cooled rocket chamber wall.
Demirakca, Traute; Sartorius, Alexander; Ende, Gabriele; Meyer, Nadja; Welzel, Helga; Skopp, Gisela; Mann, Karl; Hermann, Derik
2011-04-01
Chronic cannabis use has been associated with memory deficits and a volume reduction of the hippocampus, but none of the studies accounted for different effects of tetrahydrocannabinol (THC) and cannabidiol (CBD). Using a voxel based morphometry approach optimized for small subcortical structures (DARTEL) gray matter (GM) concentration and volume of the hippocampus were measured in 11 chronic recreational cannabis users and 13 healthy controls, and correlated with THC and CBD from hair analyses. GM volume was calculated by modulating VBM using Jacobian determinants derived from the spatial normalization. Cannabis users showed lower GM volume located in a cluster of the right anterior hippocampus (P(uncorr)=0.002; effect size Cohen's d=1.34). In a regression analysis an inverse correlation of the ratio THC/CBD with the volume of the right hippocampus (P(uncorr) p<0.001, Cohen's d=3.43) was observed. Furthermore Cannabidiol correlated positively with GM concentration (unmodulated VBM data), but not with GM volume (modulated VBM) in the bilateral hippocampus (P=0.03 after correction for hippocampal volume; left hippocampus Cohen's d=4.37 and right hippocampus 4.65). Lower volume in the right hippocampus in chronic cannabis users was corroborated. Higher THC and lower CBD was associated with this volume reduction indicating neurotoxic effects of THC and neuroprotective effects of CBD. This confirms existing preclinical and clinical results. As a possible mechanism the influence of cannabinoids on hippocampal neurogenesis is suggested. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Intravascular volume in cirrhosis. Reassessment using improved methodology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rector, W.G. Jr.; Ibarra, F.
1988-04-01
Previous studies of blood volume (BV) in cirrhosis have either not adjusted BV properly for body size; determined plasma volume from the dilution of labeled albumin 10-20 min postinjection, when some extravascular redistribution has already occurred; and/or not used the correct whole body-peripheral hematocrit ratio (0.82) in calculating whole BV from plasma volume and the peripheral hematocrit. We measured BV with attention to these considerations in 19 patients with cirrhosis and reexamined the determinants of vascular volume and the relationship between vascular volume and sodium retention. BV was calculated as plasma volume (determined from extrapolated plasma activity of intravenously injectedmore » (/sup 131/I)+albumin at time 0) divided by (peripheral hematocrit X 0.82). The result was expressed per kilogram dry body weight, determined by subtracting the mass of ascites (measured by isotope dilution; 1 liter = 1 kg) from the actual body weight of nonedematous patients. Measured and expressed in this way, BV correlated strongly with esophageal variceal size (r = 0.87, P less than 0.05), although not with net portal, right atrial, inferior vena caval, or arterial pressure, and was significantly greater in patients with sodium retention as compared to patients without sodium retention. The principal modifier of vascular volume in cirrhosis is vascular capacity, which is probably mainly determined by the extent of the portasystemic collateral circulation. Increased vascular volume in patients with sodium retention as compared to patients without sodium retention supports the overflow theory of ascites formation.« less
Gray-matter volume, midbrain dopamine D2/D3 receptors and drug craving in methamphetamine users.
Morales, A M; Kohno, M; Robertson, C L; Dean, A C; Mandelkern, M A; London, E D
2015-06-01
Dysfunction of the mesocorticolimbic system has a critical role in clinical features of addiction. Despite evidence suggesting that midbrain dopamine receptors influence amphetamine-induced dopamine release and that dopamine is involved in methamphetamine-induced neurotoxicity, associations between dopamine receptors and gray-matter volume have been unexplored in methamphetamine users. Here we used magnetic resonance imaging and [(18)F]fallypride positron emission tomography, respectively, to measure gray-matter volume (in 58 methamphetamine users) and dopamine D2/D3 receptor availability (binding potential relative to nondisplaceable uptake of the radiotracer, BPnd) (in 31 methamphetamine users and 37 control participants). Relationships between these measures and self-reported drug craving were examined. Although no difference in midbrain D2/D3 BPnd was detected between methamphetamine and control groups, midbrain D2/D3 BPnd was positively correlated with gray-matter volume in the striatum, prefrontal cortex, insula, hippocampus and temporal cortex in methamphetamine users, but not in control participants (group-by-midbrain D2/D3 BPnd interaction, P<0.05 corrected for multiple comparisons). Craving for methamphetamine was negatively associated with gray-matter volume in the insula, prefrontal cortex, amygdala, temporal cortex, occipital cortex, cerebellum and thalamus (P<0.05 corrected for multiple comparisons). A relationship between midbrain D2/D3 BPnd and methamphetamine craving was not detected. Lower midbrain D2/D3 BPnd may increase vulnerability to deficits in gray-matter volume in mesocorticolimbic circuitry in methamphetamine users, possibly reflecting greater dopamine-induced toxicity. Identifying factors that influence prefrontal and limbic volume, such as midbrain BPnd, may be important for understanding the basis of drug craving, a key factor in the maintenance of substance-use disorders.
Gray-Matter Volume, Midbrain Dopamine D2/D3 Receptors and Drug Craving in Methamphetamine Users
Morales, Angelica A.; Kohno, Milky; Robertson, Chelsea L.; Dean, Andy C.; Mandelkern, Mark A.; London, Edythe D.
2015-01-01
Dysfunction of the mesocorticolimbic system plays a critical role in clinical features of addiction. Despite evidence suggesting that midbrain dopamine receptors influence amphetamine-induced dopamine release and that dopamine is involved in methamphetamine-induced neurotoxicity, associations between dopamine receptors and gray-matter volume have been unexplored in methamphetamine users. Here we used magnetic resonance imaging and [18F]fallypride positron emission tomography, respectively, to measure gray-matter volume (in 58 methamphetamine users) and dopamine D2/D3 receptor availability (binding potential relative to nondisplaceable uptake of the radiotracer, BPnd) (in 31 methamphetamine users and 37 control participants). Relationships between these measures and self-reported drug craving were examined. Although no difference in midbrain D2/D3 BPnd was detected between methamphetamine and control groups, midbrain D2/D3 BPnd was positively correlated with gray-matter volume in the striatum, prefrontal cortex, insula, hippocampus and temporal cortex in methamphetamine users, but not in control participants (group-by-midbrain D2/D3 BPnd interaction, p<0.05 corrected for multiple comparisons). Craving for methamphetamine was negatively associated with gray-matter volume in the insula, prefrontal cortex, amygdala, temporal cortex, occipital cortex, cerebellum, and thalamus (p<0.05 corrected for multiple comparisons). A relationship between midbrain D2/D3 BPnd and methamphetamine craving was not detected. Lower midbrain D2/D3 BPnd may increase vulnerability to deficits in gray-matter volume in mesocorticolimbic circuitry in methamphetamine users, possibly reflecting greater dopamine-induced toxicity. Identifying factors that influence prefrontal and limbic volume, such as midbrain BPnd, may be important for understanding the basis of drug craving, a key factor in the maintenance of substance use disorders. PMID:25896164
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pasquier, David; Lacornerie, Thomas; Vermandel, Maximilien
Purpose: Target-volume and organ-at-risk delineation is a time-consuming task in radiotherapy planning. The development of automated segmentation tools remains problematic, because of pelvic organ shape variability. We evaluate a three-dimensional (3D), deformable-model approach and a seeded region-growing algorithm for automatic delineation of the prostate and organs-at-risk on magnetic resonance images. Methods and Materials: Manual and automatic delineation were compared in 24 patients using a sagittal T2-weighted (T2-w) turbo spin echo (TSE) sequence and an axial T1-weighted (T1-w) 3D fast-field echo (FFE) or TSE sequence. For automatic prostate delineation, an organ model-based method was used. Prostates without seminal vesicles were delineatedmore » as the clinical target volume (CTV). For automatic bladder and rectum delineation, a seeded region-growing method was used. Manual contouring was considered the reference method. The following parameters were measured: volume ratio (Vr) (automatic/manual), volume overlap (Vo) (ratio of the volume of intersection to the volume of union; optimal value = 1), and correctly delineated volume (Vc) (percent ratio of the volume of intersection to the manually defined volume; optimal value 100). Results: For the CTV, the Vr, Vo, and Vc were 1.13 ({+-}0.1 SD), 0.78 ({+-}0.05 SD), and 94.75 ({+-}3.3 SD), respectively. For the rectum, the Vr, Vo, and Vc were 0.97 ({+-}0.1 SD), 0.78 ({+-}0.06 SD), and 86.52 ({+-}5 SD), respectively. For the bladder, the Vr, Vo, and Vc were 0.95 ({+-}0.03 SD), 0.88 ({+-}0.03 SD), and 91.29 ({+-}3.1 SD), respectively. Conclusions: Our results show that the organ-model method is robust, and results in reproducible prostate segmentation with minor interactive corrections. For automatic bladder and rectum delineation, magnetic resonance imaging soft-tissue contrast enables the use of region-growing methods.« less
The density of apical cells of dark-grown protonemata of the moss Ceratodon purpureus
NASA Technical Reports Server (NTRS)
Schwuchow, J. M.; Kern, V. D.; Wagner, T.; Sack, F. D.
2000-01-01
Determinations of plant or algal cell density (cell mass divided by volume) have rarely accounted for the extracellular matrix or shrinkage during isolation. Three techniques were used to indirectly estimate the density of intact apical cells from protonemata of the moss Ceratodon purpureus. First, the volume fraction of each cell component was determined by stereology, and published values for component density were used to extrapolate to the entire cell. Second, protonemal tips were immersed in bovine serum albumin solutions of different densities, and then the equilibrium density was corrected for the mass of the cell wall. Third, apical cell protoplasts were centrifuged in low-osmolarity gradients, and values were corrected for shrinkage during protoplast isolation. Values from centrifugation (1.004 to 1.015 g/cm3) were considerably lower than from other methods (1.046 to 1.085 g/cm3). This work appears to provide the first corrected estimates of the density of any plant cell. It also documents a method for the isolation of protoplasts specifically from apical cells of protonemal filaments.
Appalakondaiah, S; Vaitheeswaran, G; Lebègue, S
2015-06-18
We have performed ab initio calculations for a series of energetic solids to explore their structural and electronic properties. To evaluate the ground state volume of these molecular solids, different dispersion correction methods were accounted in DFT, namely the Tkatchenko-Scheffler method (with and without self-consistent screening), Grimme's methods (D2, D3(BJ)), and the vdW-DF method. Our results reveal that dispersion correction methods are essential in understanding these complex structures with van der Waals interactions and hydrogen bonding. The calculated ground state volumes and bulk moduli show that the performance of each method is not unique, and therefore a careful examination is mandatory for interpreting theoretical predictions. This work also emphasizes the importance of quasiparticle calculations in predicting the band gap, which is obtained here with the GW approximation. We find that the obtained band gaps are ranging from 4 to 7 eV for the different compounds, indicating their insulating nature. In addition, we show the essential role of quasiparticle band structure calculations to correlate the gap with the energetic properties.
Rezaeetalab, Fariba; Kazemian, Mozhgan; Vaezi, Touraj; Shaban, Barratollah
2015-12-01
Bimaxillary orthognathic surgery can cause changes to respiration and the airways. We used body plethysmography to evaluate its effect on airway resistance and lung volumes in 20 patients with class III malocclusions (8 men and 12 women, aged 17 - 32 years). Lung volumes (forced vital capacity; forced inspiratory volume/one second; forced expiratory volume/one second: forced vital capacity; peak expiratory flow; maximum expiratory flow 25-75; maximum inspiratory flow; total lung capacity; residual volume; residual volume:total lung capacity), and airway resistance were evaluated one week before, and six months after, operation. Bimaxillary operations to correct class III malocclusions significantly increased airway resistance, residual volume, total lung capacity, and residual volume:total lung capacity. Other variables also changed after operation but not significantly so. Orthognathic operations should be done with caution in patients who have pre-existing respiratory diseases. Copyright © 2015 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Saxena, Udit; Allan, Chris; Allen, Prudence
2017-06-01
Previous studies have suggested elevated reflex thresholds in children with auditory processing disorders (APDs). However, some aspects of the child's ear such as ear canal volume and static compliance of the middle ear could possibly affect the measurements of reflex thresholds and thus impact its interpretation. Sound levels used to elicit reflexes in a child's ear may be higher than predicted by calibration in a standard 2-cc coupler, and lower static compliance could make visualization of very small changes in impedance at threshold difficult. For this purpose, it is important to evaluate threshold data with consideration of differences between children and adults. A set of studies were conducted. The first compared reflex thresholds obtained using standard clinical procedures in children with suspected APD to that of typically developing children and adults to test the replicability of previous studies. The second study examined the impact of ear canal volume on estimates of reflex thresholds by applying real-ear corrections. Lastly, the relationship between static compliance and reflex threshold estimates was explored. The research is a set of case-control studies with a repeated measures design. The first study included data from 20 normal-hearing adults, 28 typically developing children, and 66 children suspected of having an APD. The second study included 28 normal-hearing adults and 30 typically developing children. In the first study, crossed and uncrossed reflex thresholds were measured in 5-dB step size. Reflex thresholds were analyzed using repeated measures analysis of variance (RM-ANOVA). In the second study, uncrossed reflex thresholds, real-ear correction, ear canal volume, and static compliance were measured. Reflex thresholds were measured using a 1-dB step size. The effect of real-ear correction and static compliance on reflex threshold was examined using RM-ANOVA and Pearson correlation coefficient, respectively. Study 1 replicated previous studies showing elevated reflex thresholds in many children with suspected APD when compared to data from adults using standard clinical procedures, especially in the crossed condition. The thresholds measured in children with suspected APD tended to be higher than those measured in the typically developing children. There were no significant differences between the typically developing children and adults. However, when real-ear calibrated stimulus levels were used, it was found that children's thresholds were elicited at higher levels than in the adults. A significant relationship between reflex thresholds and static compliance was found in the adult data, showing a trend for higher thresholds in ears with lower static compliance, but no such relationship was found in the data from the children. This study suggests that reflex measures in children should be adjusted for real-ear-to-coupler differences before interpretation. The data in children with suspected APD support previous studies suggesting abnormalities in reflex thresholds. The lack of correlation between threshold and static compliance estimates in children as was observed in the adults may suggest a nonmechanical explanation for age and clinically related effects. American Academy of Audiology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakayama, Masao, E-mail: naka2008@med.kobe-u.ac.jp; Yoshida, Kenji; Nishimura, Hideki
2014-04-01
The present study aimed to investigate the effect of heterogeneity correction (HC) on dosimetric parameters in 3-dimensional conformal radiotherapy planning for patients with thoracic esophageal cancer. We retrospectively analyzed 20 patients. Two treatment plans were generated for each patient using a superposition algorithm on the Xio radiotherapy planning system. The first plan was calculated without HC. The second was a new plan calculated with HC, using identical beam geometries and maintaining the same number of monitor units as the first. With regard to the planning target volume (PTV), the overall mean differences in the prescription dose, maximum dose, mean dose,more » and dose that covers 95% of the PTV between the first and second plans were 1.10 Gy (1.8%), 1.35 Gy (2.2%), 1.10 Gy (1.9%), and 0.56 Gy (1.0%), respectively. With regard to parameters related to the organs at risk (OARs), the mean differences in the absolute percentages of lung volume receiving greater than 5, 10, 20, and 30 Gy (lung V{sub 5}, V{sub 10}, V{sub 20}, and V{sub 30}) between the first and second plans were 7.1%, 2.7%, 0.4%, and 0.5%, respectively. These results suggest that HC might have a more pronounced effect on the percentages of lung volume receiving lower doses (e.g., V{sub 5} and V{sub 10}) than on the dosimetric parameters related to the PTV and other OARs.« less
[Development of a Striatal and Skull Phantom for Quantitative 123I-FP-CIT SPECT].
Ishiguro, Masanobu; Uno, Masaki; Miyazaki, Takuma; Kataoka, Yumi; Toyama, Hiroshi; Ichihara, Takashi
123 Iodine-labelled N-(3-fluoropropyl) -2β-carbomethoxy-3β-(4-iodophenyl) nortropane ( 123 I-FP-CIT) single photon emission computerized tomography (SPECT) images are used for differential diagnosis such as Parkinson's disease (PD). Specific binding ratio (SBR) is affected by scattering and attenuation in SPECT imaging, because gender and age lead to changes in skull density. It is necessary to clarify and correct the influence of the phantom simulating the the skull. The purpose of this study was to develop phantoms that can evaluate scattering and attenuation correction. Skull phantoms were prepared based on the measuring the results of the average computed tomography (CT) value, average skull thickness of 12 males and 16 females. 123 I-FP-CIT SPECT imaging of striatal phantom was performed with these skull phantoms, which reproduced normal and PD. SPECT images, were reconstructed with scattering and attenuation correction. SBR with partial volume effect corrected (SBR act ) and conventional SBR (SBR Bolt ) were measured and compared. The striatum and the skull phantoms along with 123 I-FP-CIT were able to reproduce the normal accumulation and disease state of PD and further those reproduced the influence of skull density on SPECT imaging. The error rate with the true SBR, SBR act was much smaller than SBR Bolt . The effect on SBR could be corrected by scattering and attenuation correction even if the skull density changes with 123 I-FP-CIT on SPECT imaging. The combination of triple energy window method and CT-attenuation correction method would be the best correction method for SBR act .
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berger, Edmond L.; Gao, Jun; Zhu, Hua Xing
We present a detailed phenomenological study of the next-to-next-to-leading order (NNLO) QCD corrections for t-channel single top (anti-)quark production and its semi-leptonic decay at the CERN Large Hadron Collider (LHC). We find the NNLO corrections for the total inclusive rates at the LHC with different center of mass energies are generally smaller than the NLO corrections, indicative of improved convergence. However, they can be large for differential distributions, reaching a level of 10% or more in certain regions of the transverse momentum distributions of the top (anti-)quark and the pseudo-rapidity distributions of the leading jet in the event. In allmore » cases the perturbative hard-scale uncertainties are greatly reduced after the NNLO corrections are included. We also show a comparison of the normalized parton-level distributions to recent data from the 8 TeV measurement of the ATLAS collaboration. The NNLO corrections tend to shift the theoretical predictions closer to the measured transverse momentum distribution of the top (anti)-quark. Importantly, for the LHC at 13 TeV, we present NNLO cross sections in a fiducial volume with decays of the top quark included.« less
Study of CCT varying by volume scattering diffuser with moving and rotating white light LED
NASA Astrophysics Data System (ADS)
Ma, Shih-Hsin; Chen, Liang-Shiun; Huang, Wen-Chao
2014-09-01
In this study, the corrected color temperature (CCT) of white light, which originates from a white light LED (WLLED) and passes through a volume-scattering diffuser (VSD), is investigated. The VSD with thickness of 2mm is fabricated by mixing the 2um-sized PMMA scattering particles and the epoxy glue with different concentration values. Moreover, in order to understand the influences of the illuminated area and the scattering path of VSD on CCT values, the bulletheaded and lambertian-type WLLEDs are assembled for different positions and distinct orientations along the optical axis in a black cavity. A detailed comparison between results regarding the white light with and without passing through the VSD is offered. The results of this research will help to improve the colorful consistency of the LED lamps which use diffusers.
SU-F-T-488: Comparison of the TG-51 and TG-51 Addendum Calibration Protocols
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCaw, T; Hwang, M; Jang, S
Purpose: To quantify differences between the TG51 and TG51 addendum calibration protocols. Methods: Beam energies of 6X, 6XSRS, 10X, 15X, 23X, 6XFFF, and 10XFFF were calibrated following both the TG51 and TG51 addendum protocols using both a Farmer and a scanning ionization chamber with traceable absorbed dose-to-water calibrations. For the TG51 addendum procedure, the collimating jaws were positioned to define a 10×10cm{sup 2} radiation field, a lead foil was only used for kQ measurements of FFF energies, and a volume-averaging correction was applied based on crossline and inline dose profiles. For the TG51 procedure, the collimating jaws were set tomore » 10×10cm{sup 2} according to the digital readout, and a lead foil was used for kQ measurements of energies greater than 10MV. Results: For beam energies with a flattening filter, absorbed dose-to-water determined by the two protocols differed by 0.1%–0.3%. For FFF beam energies, differences between the protocols were up to 0.2% and 0.8% for the scanning and Farmer ionization chambers, respectively. Differences between the protocols were due to kQ determination, volume-averaging correction, and measurement of raw ionization. Differences in kQ values between the two protocols were up to 0.4% and 0.2% for the scanning and Farmer ionization chambers, respectively. Volume-averaging corrections were less than 0.1% for the scanning ionization chamber, and up to 0.4% and 0.6% for the Farmer ionization chamber in beams with a flattening filter and FFF beams, respectively. Raw ionization measurements differed up to 0.3%±0.07% due to differences in jaw settings. Conclusion: The TG51 and TG51 addendum calibration protocols differed less than 0.3% for the scanning ionization chamber. For the Farmer chamber in FFF energies, volume-averaging corrections of up to 0.6% contributed to calibration differences of up to 0.8%. Failure to verify the radiation field size can produce calibration differences of up to 0.3%.« less
Konishi, Jun; Asami, Takeshi; Hayano, Fumi; Yoshimi, Asuka; Hayasaka, Shunsuke; Fukushima, Hiroshi; Whitford, Thomas J.; Inoue, Tomio; Hirayasu, Yoshio
2014-01-01
Numerous brain regions are believed to be involved in the neuropathology of panic disorder (PD) including fronto-limbic regions, thalamus, brain stem, and cerebellum. However, while several previous studies have demonstrated volumetric gray matter reductions in these brain regions, there have been no studies evaluating volumetric white matter changes in the fiber bundles connecting these regions. In addition, although patients with PD typically exhibit social, interpersonal and occupational dysfunction, the neuropathologies underlying these dysfunctions remain unclear. A voxel-based morphometry study was conducted to evaluate differences in regional white matter volume between 40 patients with PD and 40 healthy control subjects (HC). Correlation analyses were performed between the regional white matter volumes and patients' scores on the Panic Disorder Severity Scale (PDSS) and the Global Assessment of Functioning (GAF). Patients with PD demonstrated significant volumetric reductions in widespread white matter regions including fronto-limbic, thalamo-cortical and cerebellar pathways (p<0.05, FDR corrected). Furthermore, there was a significant negative relationship between right orbitofrontal gyrus (OFG) white matter volume and the severity of patients' clinical symptoms, as assessed with the PDSS. A significant positive relationship was also observed between patients' right OFG volumes and their scores on the GAF. Our results suggest that volumetric reductions in widespread white matter regions may play an important role in the pathology of PD. In particular, our results suggest that structural white matter abnormalities in the right OFG may contribute to the social, personal and occupational dysfunction typically experienced by patients with PD. PMID:24663245
NASA Astrophysics Data System (ADS)
Pasten-Zapata, Ernesto; Jones, Julie; Moggridge, Helen
2015-04-01
As climate change is expected to generate variations on the Earth's precipitation and temperature, the water cycle will also experience changes. Consequently, water users will have to be prepared for possible changes in future water availability. The main objective of this research is to evaluate the impacts of climate change on river regimes and the implications to the operation and feasibility of run of the river hydropower schemes by analyzing four UK study sites. Run of the river schemes are selected for analysis due to their higher dependence to the available river flow volumes when compared to storage hydropower schemes that can rely on previously accumulated water volumes (linked to poster in session HS5.3). Global Climate Models (GCMs) represent the main tool to assess future climate change. In this research, Regional Climate Models (RCMs), which dynamically downscale GCM outputs providing higher resolutions, are used as starting point to evaluate climate change within the study catchments. RCM daily temperature and precipitation will be downscaled to an appropriate scale for impact studies and bias corrected using different statistical methods: linear scaling, local intensity scaling, power transformation, variance scaling and delta change correction. The downscaled variables will then be coupled to hydrological models that have been previously calibrated and validated against observed daily river flow data. The coupled hydrological and climate models will then be used to simulate historic river flows that are compared to daily observed values in order to evaluate the model accuracy. As this research will employ several different RCMs (from the EURO-CORDEX simulations), downscaling and bias correction methodologies, greenhouse emission scenarios and hydrological models, the uncertainty of each element will be estimated. According to their uncertainty magnitude, a prediction of the best downscaling approach (or approaches) is expected to be obtained. The current progress of the project will be presented along with the steps to be followed in the future.
ERIC Educational Resources Information Center
van Kooij, Britt J. M.; Benders, Manon J. N. L.; Anbeek, Petronella; van Haastert, Ingrid C.; de Vries, Linda S.; Groenendaal, Floris
2012-01-01
Aim: To assess the relation between cerebellar volume and spectroscopy at term equivalent age, and neurodevelopment at 24 months corrected age in preterm infants. Methods: Magnetic resonance imaging of the brain was performed around term equivalent age in 112 preterm infants (mean gestational age 28wks 3d [SD 1wk 5d]; birthweight 1129g [SD 324g]).…
Moments of the Wigner function and Renyi entropies at freeze-out
NASA Astrophysics Data System (ADS)
Bialas, A.; Czyz, W.; Zalewski, K.
2006-03-01
The relation between Renyi entropies and moments of the Wigner function, representing the quantum mechanical description of the M-particle semi-inclusive distribution at freeze-out, is investigated. It is shown that in the limit of infinite volume of the system, the classical and quantum descriptions are equivalent. Finite volume corrections are derived and shown to be small for systems encountered in relativistic heavy ion collisions.
1998-02-13
National Practitioner Data Bank; Change in User Fee and Elimination of Diskette Queries notice, document 98-2637, pages 5811-5812, Volume 63, Number 23, in the issue of Wednesday, February 4, 1998, was published in error and is withdrawn from publication. The correct version of the notice was published on Thursday, January 29, 1998, Document No. 98-2116, Volume 63, Number 19, page 4460.
Denaturation process of laccase in various media by refractive index measurements.
Saoudi, O; Ghaouar, N; Ben Salah, S; Othman, T
2017-09-01
In this work, we are interested in the denaturation process of a laccase from Tramates versicolor via the determination of the refractive index, the refractive index increment and the specific volume in various media. The measurements were carried out using an Abbe refractometer. We have shown that the refractive index increment values obtained from the slope of the variation of the refractive index vs. Concentration are outside the range refractive index increments of proteins. To correct the results, we have followed the theoretical predictions based on the knowledge of the protein refractive index from its amino acids composition. The denaturation process was studied by calculating the specific volume variation where its determination was related to the Gladstone-Dale and the Lorentz-Lorentz models.
Registration of in vivo MR to histology of rodent brains using blockface imaging
NASA Astrophysics Data System (ADS)
Uberti, Mariano; Liu, Yutong; Dou, Huanyu; Mosley, R. Lee; Gendelman, Howard E.; Boska, Michael
2009-02-01
Registration of MRI to histopathological sections can enhance bioimaging validation for use in pathobiologic, diagnostic, and therapeutic evaluations. However, commonly used registration methods fall short of this goal due to tissue shrinkage and tearing after brain extraction and preparation. In attempts to overcome these limitations we developed a software toolbox using 3D blockface imaging as the common space of reference. This toolbox includes a semi-automatic brain extraction technique using constraint level sets (CLS), 3D reconstruction methods for the blockface and MR volume, and a 2D warping technique using thin-plate splines with landmark optimization. Using this toolbox, the rodent brain volume is first extracted from the whole head MRI using CLS. The blockface volume is reconstructed followed by 3D brain MRI registration to the blockface volume to correct the global deformations due to brain extraction and fixation. Finally, registered MRI and histological slices are warped to corresponding blockface images to correct slice specific deformations. The CLS brain extraction technique was validated by comparing manual results showing 94% overlap. The image warping technique was validated by calculating target registration error (TRE). Results showed a registration accuracy of a TRE < 1 pixel. Lastly, the registration method and the software tools developed were used to validate cell migration in murine human immunodeficiency virus type one encephalitis.
Joustra, Sjoerd D; van der Plas, Evelyn M; Goede, Joery; Oostdijk, Wilma; Delemarre-van de Waal, Henriette A; Hack, Wilfried W M; van Buuren, Stef; Wit, Jan M
2015-06-01
Accurate calculations of testicular volume standard deviation (SD) scores are not currently available. We constructed LMS-smoothed age-reference charts for testicular volume in healthy boys. The LMS method was used to calculate reference data, based on testicular volumes from ultrasonography and Prader orchidometer of 769 healthy Dutch boys aged 6 months to 19 years. We also explored the association between testicular growth and pubic hair development, and data were compared to orchidometric testicular volumes from the 1997 Dutch nationwide growth study. The LMS-smoothed reference charts showed that no revision of the definition of normal onset of male puberty - from nine to 14 years of age - was warranted. In healthy boys, the pubic hair stage SD scores corresponded with testicular volume SD scores (r = 0.394). However, testes were relatively small for pubic hair stage in Klinefelter's syndrome and relatively large in immunoglobulin superfamily member 1 deficiency syndrome. The age-corrected SD scores for testicular volume will aid in the diagnosis and follow-up of abnormalities in the timing and progression of male puberty and in research evaluations. The SD scores can be compared with pubic hair SD scores to identify discrepancies between cell functions that result in relative microorchidism or macroorchidism. ©2015 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
Validity of Three-Dimensional Photonic Scanning Technique for Estimating Percent Body Fat.
Shitara, K; Kanehisa, H; Fukunaga, T; Yanai, T; Kawakami, Y
2013-01-01
Three-dimensional photonic scanning (3DPS) was recently developed to measure dimensions of a human body surface. The purpose of this study was to explore the validity of body volume measured by 3DPS for estimating the percent body fat (%fat). Design, setting, participants, and measurement: The body volumes were determined by 3DPS in 52 women. The body volume was corrected for residual lung volume. The %fat was estimated from body density and compared with the corresponding reference value determined by the dual-energy x-ray absorptiometry (DXA). No significant difference was found for the mean values of %fat obtained by 3DPS (22.2 ± 7.6%) and DXA (23.5 ± 4.9%). The root mean square error of %fat between 3DPS and reference technique was 6.0%. For each body segment, there was a significant positive correlation between 3DPS- and DXA-values, although the corresponding value for the head was slightly larger in 3DPS than in DXA. Residual lung volume was negatively correlated with the estimated error in %fat. The body volume determined with 3DPS is potentially useful for estimating %fat. A possible strategy for enhancing the measurement accuracy of %fat might be to refine the protocol for preparing the subject's hair prior to scanning and to improve the accuracy in the measurement of residual lung volume.
Testing of Error-Correcting Sparse Permutation Channel Codes
NASA Technical Reports Server (NTRS)
Shcheglov, Kirill, V.; Orlov, Sergei S.
2008-01-01
A computer program performs Monte Carlo direct numerical simulations for testing sparse permutation channel codes, which offer strong error-correction capabilities at high code rates and are considered especially suitable for storage of digital data in holographic and volume memories. A word in a code of this type is characterized by, among other things, a sparseness parameter (M) and a fixed number (K) of 1 or "on" bits in a channel block length of N.
The Coast Artillery Journal. Volume 66, Number 5, May 1927
1927-05-01
We are losing our sense of propor- tion and computing to ounces from measurements accurate only to pounds. Pursuing this subject further, it is...assumed. 2. The wind effect is supposedly corrected for through the use of the wind computer . Actually the present wind computer does not fur- nish...unsuited for the application of the correction (the Model 1917 Data Computer ) by operators too busy with principal deflections to occupy themselves
Fazio, Patrik; Schain, Martin; Mrzljak, Ladislav; Amini, Nahid; Nag, Sangram; Al-Tawil, Nabil; Fitzer-Attas, Cheryl J; Bronzova, Juliana; Landwehrmeyer, Bernhard; Sampaio, Cristina; Halldin, Christer; Varrone, Andrea
2017-05-15
Phosphodiesterase 10A enzyme (PDE10A) is an important striatal target that has been shown to be affected in patients with neurodegenerative disorders, particularly Huntington´s disease (HD). PDE10A is expressed on striatal neurones in basal ganglia where other known molecular targets are enriched such as dopamine D 2/3 receptors (D 2/3 R). The aim of this study was to examine the availability of PDE10A enzyme in relation with age and gender and to compare those changes with those related to D 2/3 R and volumes in different regions of the basal ganglia. As a secondary objective we examined the relative distribution of D 2/3 R and PDE10A enzyme in the striatum and globus pallidus. Forty control subjects (20F/20M; age: 44±11y, age range 27-69) from an ongoing positron emission tomography (PET) study in HD gene expansion carriers were included. Subjects were examined with PET using the high-resolution research tomograph (HRRT) and with 3T magnetic resonance imaging (MRI). The PDE10A radioligand 18 F-MNI-659 and D 2/3 R radioligand 11 C-raclopride were used. The outcome measure was the binding potential (BP ND ) estimated with the two-tissue compartment model ( 18 F-MNI-659) and the simplified reference tissue model ( 11 C-raclopride) using the cerebellum as reference region. The PET data were corrected for partial volume effects. In the striatum, PDE10A availability showed a significant age-related decline that was larger compared to the age-related decline of D 2/3 R availability and to the age-related decline of volumes measured with MRI. In the globus pallidus, a less pronounced decline of PDE10A availability was observed, whereas D 2/3 R availability and volumes seemed to be rather stable with aging. The distribution of the PDE10A enzyme was different from the distribution of D 2/3 R, with higher availability in the globus pallidus. These results indicate that aging is associated with a considerable physiological reduction of the availability of PDE10A enzyme in the striatum. Moreover as result of the analysis, in the striatum for both the molecular targets, we observed a gender effect with higher BP ND the female group. Copyright © 2017 Elsevier Inc. All rights reserved.
Toh, Cheng Hong; Wei, Kuo-Chen; Chang, Chen-Nen; Ng, Shu-Hang; Wong, Ho-Fai; Lin, Ching-Po
2014-01-01
To compare the diagnostic performance of dynamic susceptibility contrast-enhanced perfusion MRI before and after mathematic contrast leakage correction in differentiating pyogenic brain abscesses from glioblastomas and/or metastatic brain tumors. Cerebral blood volume (CBV), leakage-corrected CBV and leakage coefficient K2 were measured in enhancing rims, perifocal edema and contralateral normal appearing white matter (NAWM) of 17 abscesses, 19 glioblastomas and 20 metastases, respectively. The CBV and corrected CBV were normalized by dividing the values in the enhancing rims or edema to those of contralateral NAWM. For each study group, a paired t test was used to compare the K2 of the enhancing rims or edema with those of NAWM, as well as between CBV and corrected CBV of the enhancing rims or edema. ANOVA was used to compare CBV, corrected CBV and K2 among three lesion types. The diagnostic performance of CBV and corrected CBV was assessed with receiver operating characteristic (ROC) curve analysis. The CBV and correction CBV of enhancing rim were 1.45±1.17 and 1.97±1.01 for abscesses, 3.85±2.19 and 4.39±2.33 for glioblastomas, and 2.39±0.90 and 2.97±0.78 for metastases, respectively. The CBV and corrected CBV in the enhancing rim of abscesses were significantly lower than those of glioblastomas and metastases (P = 0.001 and P = 0.007, respectively). In differentiating abscesses from glioblastomas and metastases, the AUC values of corrected CBV (0.822) were slightly higher than those of CBV (0.792). Mathematic leakage correction slightly increases the diagnostic performance of CBV in differentiating pyogenic abscesses from necrotic glioblastomas and cystic metastases. Clinically, DSC perfusion MRI may not need mathematic leakage correction in differentiating abscesses from glioblastomas and/or metastases.
Lorenz, Kevin S.; Salama, Paul; Dunn, Kenneth W.; Delp, Edward J.
2013-01-01
Digital image analysis is a fundamental component of quantitative microscopy. However, intravital microscopy presents many challenges for digital image analysis. In general, microscopy volumes are inherently anisotropic, suffer from decreasing contrast with tissue depth, lack object edge detail, and characteristically have low signal levels. Intravital microscopy introduces the additional problem of motion artifacts, resulting from respiratory motion and heartbeat from specimens imaged in vivo. This paper describes an image registration technique for use with sequences of intravital microscopy images collected in time-series or in 3D volumes. Our registration method involves both rigid and non-rigid components. The rigid registration component corrects global image translations, while the non-rigid component manipulates a uniform grid of control points defined by B-splines. Each control point is optimized by minimizing a cost function consisting of two parts: a term to define image similarity, and a term to ensure deformation grid smoothness. Experimental results indicate that this approach is promising based on the analysis of several image volumes collected from the kidney, lung, and salivary gland of living rodents. PMID:22092443
Finite size effects in the thermodynamics of a free neutral scalar field
NASA Astrophysics Data System (ADS)
Parvan, A. S.
2018-04-01
The exact analytical lattice results for the partition function of the free neutral scalar field in one spatial dimension in both the configuration and the momentum space were obtained in the framework of the path integral method. The symmetric square matrices of the bilinear forms on the vector space of fields in both configuration space and momentum space were found explicitly. The exact lattice results for the partition function were generalized to the three-dimensional spatial momentum space and the main thermodynamic quantities were derived both on the lattice and in the continuum limit. The thermodynamic properties and the finite volume corrections to the thermodynamic quantities of the free real scalar field were studied. We found that on the finite lattice the exact lattice results for the free massive neutral scalar field agree with the continuum limit only in the region of small values of temperature and volume. However, at these temperatures and volumes the continuum physical quantities for both massive and massless scalar field deviate essentially from their thermodynamic limit values and recover them only at high temperatures or/and large volumes in the thermodynamic limit.
Intra-fraction motion of larynx radiotherapy
NASA Astrophysics Data System (ADS)
Durmus, Ismail Faruk; Tas, Bora
2018-02-01
In early stage laryngeal radiotherapy, movement is an important factor. Thyroid cartilage can move from swallowing, breathing, sound and reflexes. The effects of this motion on the target volume (PTV) during treatment were examined. In our study, the target volume movement during the treatment for this purpose was examined. Thus, setup margins are re-evaluated and patient-based PTV margins are determined. Intrafraction CBCT was scanned in 246 fractions for 14 patients. During the treatment, the amount of deviation which could be lateral, vertical and longitudinal axis was determined. ≤ ± 0.1cm deviation; 237 fractions in the lateral direction, 202 fractions in the longitudinal direction, 185 fractions in the vertical direction. The maximum deviation values were found in the longitudinal direction. Intrafraction guide in laryngeal radiotherapy; we are sure of the correctness of the treatment, the target volume is to adjust the margin and dose more precisely, we control the maximum deviation of the target volume for each fraction. Although the image quality of intrafraction-CBCT scans was lower than the image quality of planning CT, they showed sufficient contrast for this work.
Numerical Analysis of Plasma Transport in Tandem Volume Magnetic Multicusp Ion Sources
1992-03-01
the results of the model are qualitatively correct. Boltzmann Equation, Ion Sources, Plasma Simulation, Electron Temperature, Plasma Density, Ion Temperature, Hydrogen Ions, Magnetic Filters, Hydrogen Plasma Chemistry .
Red cell volume with changes in plasma osmolarity during maximal exercise.
NASA Technical Reports Server (NTRS)
Van Beaumont, W.
1973-01-01
The volume of the red cell in vivo was measured during acute changes in plasma osmolarity evoked through short (6 to 8 min) maximal exercise in six male volunteer subjects. Simultaneous measurements of mean corpuscular red cell volume (MCV), hematocrit, blood hemoglobin, mean corpuscular hemoglobin concentration (MCHC), and plasma osmolarity showed that there was no change in the MCV or MCHC with a concomitant rise of nearly 6% in plasma osmolarity. Apparently, in vivo, the volume of the red cell in exercising healthy human subjects does not change measurably, in spite of significant changes in osmotic pressure of the surrounding medium. Consequently, it is not justified to correct postexercise hematocrit measurements for changes in plasma osmolarity.
MRI-guided brain PET image filtering and partial volume correction
NASA Astrophysics Data System (ADS)
Yan, Jianhua; Chu-Shern Lim, Jason; Townsend, David W.
2015-02-01
Positron emission tomography (PET) image quantification is a challenging problem due to limited spatial resolution of acquired data and the resulting partial volume effects (PVE), which depend on the size of the structure studied in relation to the spatial resolution and which may lead to over or underestimation of the true tissue tracer concentration. In addition, it is usually necessary to perform image smoothing either during image reconstruction or afterwards to achieve a reasonable signal-to-noise ratio. Typically, an isotropic Gaussian filtering (GF) is used for this purpose. However, the noise suppression is at the cost of deteriorating spatial resolution. As hybrid imaging devices such as PET/MRI have become available, the complementary information derived from high definition morphologic images could be used to improve the quality of PET images. In this study, first of all, we propose an MRI-guided PET filtering method by adapting a recently proposed local linear model and then incorporate PVE into the model to get a new partial volume correction (PVC) method without parcellation of MRI. In addition, both the new filtering and PVC are voxel-wise non-iterative methods. The performance of the proposed methods were investigated with simulated dynamic FDG brain dataset and 18F-FDG brain data of a cervical cancer patient acquired with a simultaneous hybrid PET/MR scanner. The initial simulation results demonstrated that MRI-guided PET image filtering can produce less noisy images than traditional GF and bias and coefficient of variation can be further reduced by MRI-guided PET PVC. Moreover, structures can be much better delineated in MRI-guided PET PVC for real brain data.
Inter- and Intrafraction Uncertainty in Prostate Bed Image-Guided Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Kitty; Palma, David A.; Department of Oncology, University of Western Ontario, London
2012-10-01
Purpose: The goals of this study were to measure inter- and intrafraction setup error and prostate bed motion (PBM) in patients undergoing post-prostatectomy image-guided radiotherapy (IGRT) and to propose appropriate population-based three-dimensional clinical target volume to planning target volume (CTV-PTV) margins in both non-IGRT and IGRT scenarios. Methods and Materials: In this prospective study, 14 patients underwent adjuvant or salvage radiotherapy to the prostate bed under image guidance using linac-based kilovoltage cone-beam CT (kV-CBCT). Inter- and intrafraction uncertainty/motion was assessed by offline analysis of three consecutive daily kV-CBCT images of each patient: (1) after initial setup to skin marks, (2)more » after correction for positional error/immediately before radiation treatment, and (3) immediately after treatment. Results: The magnitude of interfraction PBM was 2.1 mm, and intrafraction PBM was 0.4 mm. The maximum inter- and intrafraction prostate bed motion was primarily in the anterior-posterior direction. Margins of at least 3-5 mm with IGRT and 4-7 mm without IGRT (aligning to skin marks) will ensure 95% of the prescribed dose to the clinical target volume in 90% of patients. Conclusions: PBM is a predominant source of intrafraction error compared with setup error and has implications for appropriate PTV margins. Based on inter- and estimated intrafraction motion of the prostate bed using pre- and post-kV-CBCT images, CBCT IGRT to correct for day-to-day variances can potentially reduce CTV-PTV margins by 1-2 mm. CTV-PTV margins for prostate bed treatment in the IGRT and non-IGRT scenarios are proposed; however, in cases with more uncertainty of target delineation and image guidance accuracy, larger margins are recommended.« less
Quantification of adipose tissue in a rodent model of obesity
NASA Astrophysics Data System (ADS)
Johnson, David H.; Flask, Chris; Wan, Dinah; Ernsberger, Paul; Wilson, David L.
2006-03-01
Obesity is a global epidemic and a comorbidity for many diseases. We are using MRI to characterize obesity in rodents, especially with regard to visceral fat. Rats were scanned on a 1.5T clinical scanner, and a T1W, water-spoiled image (fat only) was divided by a matched T1W image (fat + water) to yield a ratio image related to the lipid content in each voxel. The ratio eliminated coil sensitivity inhomogeneity and gave flat values across a fat pad, except for outlier voxels (> 1.0) due to motion. Following sacrifice, fat pad volumes were dissected and measured by displacement in canola oil. In our study of 6 lean (SHR), 6 dietary obese (SHR-DO), and 9 genetically obese rats (SHROB), significant differences in visceral fat volume was observed with an average of 29+/-16 ml increase due to diet and 84+/-44 ml increase due to genetics relative to lean control with a volume of 11+/-4 ml. Subcutaneous fat increased 14+/-8 ml due to diet and 198+/-105 ml due to genetics relative to the lean control with 7+/-3 ml. Visceral fat strongly correlated between MRI and dissection (R2 = 0.94), but MRI detected over five times the subcutaneous fat found with error-prone dissection. Using a semi-automated images segmentation method on the ratio images, intra-subject variation was very low. Fat pad composition as estimated from ratio images consistently differentiated the strains with SHROB having a greater lipid concentration in adipose tissues. Future work will include in vivo studies of diet versus genetics, identification of new phenotypes, and corrective measures for obesity; technical efforts will focus on correction for motion and automation in quantification.
Corrections of clinical chemistry test results in a laboratory information system.
Wang, Sihe; Ho, Virginia
2004-08-01
The recently released reports by the Institute of Medicine, To Err Is Human and Patient Safety, have received national attention because of their focus on the problem of medical errors. Although a small number of studies have reported on errors in general clinical laboratories, there are, to our knowledge, no reported studies that focus on errors in pediatric clinical laboratory testing. To characterize the errors that have caused corrections to have to be made in pediatric clinical chemistry results in the laboratory information system, Misys. To provide initial data on the errors detected in pediatric clinical chemistry laboratories in order to improve patient safety in pediatric health care. All clinical chemistry staff members were informed of the study and were requested to report in writing when a correction was made in the laboratory information system, Misys. Errors were detected either by the clinicians (the results did not fit the patients' clinical conditions) or by the laboratory technologists (the results were double-checked, and the worksheets were carefully examined twice a day). No incident that was discovered before or during the final validation was included. On each Monday of the study, we generated a report from Misys that listed all of the corrections made during the previous week. We then categorized the corrections according to the types and stages of the incidents that led to the corrections. A total of 187 incidents were detected during the 10-month study, representing a 0.26% error detection rate per requisition. The distribution of the detected incidents included 31 (17%) preanalytic incidents, 46 (25%) analytic incidents, and 110 (59%) postanalytic incidents. The errors related to noninterfaced tests accounted for 50% of the total incidents and for 37% of the affected tests and orderable panels, while the noninterfaced tests and panels accounted for 17% of the total test volume in our laboratory. This pilot study provided the rate and categories of errors detected in a pediatric clinical chemistry laboratory based on the corrections of results in the laboratory information system. A direct interface of the instruments to the laboratory information system showed that it had favorable effects on reducing laboratory errors.
Dalwani, Manish S; McMahon, Mary Agnes; Mikulich-Gilbertson, Susan K; Young, Susan E; Regner, Michael F; Raymond, Kristen M; McWilliams, Shannon K; Banich, Marie T; Tanabe, Jody L; Crowley, Thomas J; Sakai, Joseph T
2015-01-01
Structural neuroimaging studies have demonstrated lower regional gray matter volume in adolescents with severe substance and conduct problems. These research studies, including ours, have generally focused on male-only or mixed-sex samples of adolescents with conduct and/or substance problems. Here we compare gray matter volume between female adolescents with severe substance and conduct problems and female healthy controls of similar ages. Female adolescents with severe substance and conduct problems will show significantly less gray matter volume in frontal regions critical to inhibition (i.e. dorsolateral prefrontal cortex and ventrolateral prefrontal cortex), conflict processing (i.e., anterior cingulate), valuation of expected outcomes (i.e., medial orbitofrontal cortex) and the dopamine reward system (i.e. striatum). We conducted whole-brain voxel-based morphometric comparison of structural MR images of 22 patients (14-18 years) with severe substance and conduct problems and 21 controls of similar age using statistical parametric mapping (SPM) and voxel-based morphometric (VBM8) toolbox. We tested group differences in regional gray matter volume with analyses of covariance, adjusting for age and IQ at p<0.05, corrected for multiple comparisons at whole-brain cluster-level threshold. Female adolescents with severe substance and conduct problems compared to controls showed significantly less gray matter volume in right dorsolateral prefrontal cortex, left ventrolateral prefrontal cortex, medial orbitofrontal cortex, anterior cingulate, bilateral somatosensory cortex, left supramarginal gyrus, and bilateral angular gyrus. Considering the entire brain, patients had 9.5% less overall gray matter volume compared to controls. Female adolescents with severe substance and conduct problems in comparison to similarly aged female healthy controls showed substantially lower gray matter volume in brain regions involved in inhibition, conflict processing, valuation of outcomes, decision-making, reward, risk-taking, and rule-breaking antisocial behavior.
Henderson, Lauren A; Loring, Stephen H; Gill, Ritu R; Liao, Katherine P; Ishizawar, Rumey; Kim, Susan; Perlmutter-Goldenson, Robin; Rothman, Deborah; Son, Mary Beth F; Stoll, Matthew L; Zemel, Lawrence S; Sandborg, Christy; Dellaripa, Paul F; Nigrovic, Peter A
2013-03-01
The pathophysiology of shrinking lung syndrome (SLS) is poorly understood. We sought to define the structural basis for this condition through the study of pulmonary mechanics in affected patients. Since 2007, most patients evaluated for SLS at our institutions have undergone standardized respiratory testing including esophageal manometry. We analyzed these studies to define the physiological abnormalities driving respiratory restriction. Chest computed tomography data were post-processed to quantify lung volume and parenchymal density. Six cases met criteria for SLS. All presented with dyspnea as well as pleurisy and/or transient pleural effusions. Chest imaging results were free of parenchymal disease and corrected diffusing capacities were normal. Total lung capacities were 39%-50% of predicted. Maximal inspiratory pressures were impaired at high lung volumes, but not low lung volumes, in 5 patients. Lung compliance was strikingly reduced in all patients, accompanied by increased parenchymal density. Patients with SLS exhibited symptomatic and/or radiographic pleuritis associated with 2 characteristic physiological abnormalities: (1) impaired respiratory force at high but not low lung volumes; and (2) markedly decreased pulmonary compliance in the absence of identifiable interstitial lung disease. These findings suggest a model in which pleural inflammation chronically impairs deep inspiration, for example through neural reflexes, leading to parenchymal reorganization that impairs lung compliance, a known complication of persistently low lung volumes. Together these processes could account for the association of SLS with pleuritis as well as the gradual symptomatic and functional progression that is a hallmark of this syndrome.
NASA Astrophysics Data System (ADS)
Zhou, Qianqian; Leng, Guoyong; Huang, Maoyi
2018-01-01
As China becomes increasingly urbanised, flooding has become a regular occurrence in its major cities. Assessing the effects of future climate change on urban flood volumes is crucial to informing better management of such disasters given the severity of the devastating impacts of flooding (e.g. the 2016 flooding events across China). Although recent studies have investigated the impacts of future climate change on urban flooding, the effects of both climate change mitigation and adaptation have rarely been accounted for together in a consistent framework. In this study, we assess the benefits of mitigating climate change by reducing greenhouse gas (GHG) emissions and locally adapting to climate change by modifying drainage systems to reduce urban flooding under various climate change scenarios through a case study conducted in northern China. The urban drainage model - Storm Water Management Model - was used to simulate urban flood volumes using current and two adapted drainage systems (i.e. pipe enlargement and low-impact development, LID), driven by bias-corrected meteorological forcing from five general circulation models in the Coupled Model Intercomparison Project Phase 5 archive. Results indicate that urban flood volume is projected to increase by 52 % over 2020-2040 compared to the volume in 1971-2000 under the business-as-usual scenario (i.e. Representative Concentration Pathway (RCP) 8.5). The magnitudes of urban flood volumes are found to increase nonlinearly with changes in precipitation intensity. On average, the projected flood volume under RCP 2.6 is 13 % less than that under RCP 8.5, demonstrating the benefits of global-scale climate change mitigation efforts in reducing local urban flood volumes. Comparison of reduced flood volumes between climate change mitigation and local adaptation (by improving drainage systems) scenarios suggests that local adaptation is more effective than climate change mitigation in reducing future flood volumes. This has broad implications for the research community relative to drainage system design and modelling in a changing environment. This study highlights the importance of accounting for local adaptation when coping with future urban floods.
Zhou, Qianqian; Leng, Guoyong; Huang, Maoyi
2018-01-15
As China becomes increasingly urbanised, flooding has become a regular occurrence in its major cities. Assessing the effects of future climate change on urban flood volumes is crucial to informing better management of such disasters given the severity of the devastating impacts of flooding (e.g. the 2016 flooding events across China). Although recent studies have investigated the impacts of future climate change on urban flooding, the effects of both climate change mitigation and adaptation have rarely been accounted for together in a consistent framework. In this study, we assess the benefits of mitigating climate change by reducing greenhouse gas (GHG)more » emissions and locally adapting to climate change by modifying drainage systems to reduce urban flooding under various climate change scenarios through a case study conducted in northern China. The urban drainage model – Storm Water Management Model – was used to simulate urban flood volumes using current and two adapted drainage systems (i.e. pipe enlargement and low-impact development, LID), driven by bias-corrected meteorological forcing from five general circulation models in the Coupled Model Intercomparison Project Phase 5 archive. Results indicate that urban flood volume is projected to increase by 52 % over 2020–2040 compared to the volume in 1971–2000 under the business-as-usual scenario (i.e. Representative Concentration Pathway (RCP) 8.5). The magnitudes of urban flood volumes are found to increase nonlinearly with changes in precipitation intensity. On average, the projected flood volume under RCP 2.6 is 13 % less than that under RCP 8.5, demonstrating the benefits of global-scale climate change mitigation efforts in reducing local urban flood volumes. Comparison of reduced flood volumes between climate change mitigation and local adaptation (by improving drainage systems) scenarios suggests that local adaptation is more effective than climate change mitigation in reducing future flood volumes. This has broad implications for the research community relative to drainage system design and modelling in a changing environment. Furthermore, this study highlights the importance of accounting for local adaptation when coping with future urban floods.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Qianqian; Leng, Guoyong; Huang, Maoyi
As China becomes increasingly urbanised, flooding has become a regular occurrence in its major cities. Assessing the effects of future climate change on urban flood volumes is crucial to informing better management of such disasters given the severity of the devastating impacts of flooding (e.g. the 2016 flooding events across China). Although recent studies have investigated the impacts of future climate change on urban flooding, the effects of both climate change mitigation and adaptation have rarely been accounted for together in a consistent framework. In this study, we assess the benefits of mitigating climate change by reducing greenhouse gas (GHG)more » emissions and locally adapting to climate change by modifying drainage systems to reduce urban flooding under various climate change scenarios through a case study conducted in northern China. The urban drainage model – Storm Water Management Model – was used to simulate urban flood volumes using current and two adapted drainage systems (i.e. pipe enlargement and low-impact development, LID), driven by bias-corrected meteorological forcing from five general circulation models in the Coupled Model Intercomparison Project Phase 5 archive. Results indicate that urban flood volume is projected to increase by 52 % over 2020–2040 compared to the volume in 1971–2000 under the business-as-usual scenario (i.e. Representative Concentration Pathway (RCP) 8.5). The magnitudes of urban flood volumes are found to increase nonlinearly with changes in precipitation intensity. On average, the projected flood volume under RCP 2.6 is 13 % less than that under RCP 8.5, demonstrating the benefits of global-scale climate change mitigation efforts in reducing local urban flood volumes. Comparison of reduced flood volumes between climate change mitigation and local adaptation (by improving drainage systems) scenarios suggests that local adaptation is more effective than climate change mitigation in reducing future flood volumes. This has broad implications for the research community relative to drainage system design and modelling in a changing environment. Furthermore, this study highlights the importance of accounting for local adaptation when coping with future urban floods.« less
Frie, Jakob; Padilla, Nelly; Ådén, Ulrika; Lagercrantz, Hugo; Bartocci, Marco
2016-05-01
To compare cortical hemodynamic responses to known and unknown facial stimuli between infants born extremely preterm and term-born infants, and to correlate the responses of the extremely preterm-born infants to regional cortical volumes at term-equivalent age. We compared 27 infants born extremely preterm (<28 gestational weeks) with 26 term-born infants. Corrected age and chronological age at testing were between 6 and 10 months, respectively. Both groups were exposed to a gray background, their mother's face, and an unknown face. Cerebral regional concentrations of oxygenated and deoxygenated hemoglobin were measured with near-infrared spectroscopy. In the preterm group, we also performed structural brain magnetic resonance imaging and correlated regional cortical volumes to hemodynamic responses. The preterm-born infants demonstrated different cortical face recognition processes than the term-born infants. They had a significantly smaller hemodynamic response in the right frontotemporal areas while watching their mother's face (0.13 μmol/L vs 0.63 μmol/L; P < .001). We also found a negative correlation between the magnitude of the oxygenated hemoglobin increase in the right frontotemporal cortex and regional gray matter volume in the left fusiform gyrus and amygdala (voxels, 25; r = 0.86; P < .005). At 6-10 months corrected age, the preterm-born infants demonstrated a different pattern in the maturation of their cortical face recognition process compared with term-born infants. Copyright © 2016 Elsevier Inc. All rights reserved.
Design, simulation, and optimization of an RGB polarization independent transmission volume hologram
NASA Astrophysics Data System (ADS)
Mahamat, Adoum Hassan
Volume phase holographic (VPH) gratings have been designed for use in many areas of science and technology such as optical communication, medical imaging, spectroscopy and astronomy. The goal of this dissertation is to design a volume phase holographic grating that provides diffraction efficiencies of at least 70% for the entire visible wavelengths and higher than 90% for red, green, and blue light when the incident light is unpolarized. First, the complete design, simulation and optimization of the volume hologram are presented. The optimization is done using a Monte Carlo analysis to solve for the index modulation needed to provide higher diffraction efficiencies. The solutions are determined by solving the diffraction efficiency equations determined by Kogelnik's two wave coupled-wave theory. The hologram is further optimized using the rigorous coupled-wave analysis to correct for effects of absorption omitted by Kogelnik's method. Second, the fabrication or recording process of the volume hologram is described in detail. The active region of the volume hologram is created by interference of two coherent beams within the thin film. Third, the experimental set up and measurement of some properties including the diffraction efficiencies of the volume hologram, and the thickness of the active region are conducted. Fourth, the polarimetric response of the volume hologram is investigated. The polarization study is developed to provide insight into the effect of the refractive index modulation onto the polarization state and diffraction efficiency of incident light.
MR-assisted PET motion correction in simultaneous PET/MRI studies of dementia subjects.
Chen, Kevin T; Salcedo, Stephanie; Chonde, Daniel B; Izquierdo-Garcia, David; Levine, Michael A; Price, Julie C; Dickerson, Bradford C; Catana, Ciprian
2018-03-08
Subject motion in positron emission tomography (PET) studies leads to image blurring and artifacts; simultaneously acquired magnetic resonance imaging (MRI) data provides a means for motion correction (MC) in integrated PET/MRI scanners. To assess the effect of realistic head motion and MR-based MC on static [ 18 F]-fluorodeoxyglucose (FDG) PET images in dementia patients. Observational study. Thirty dementia subjects were recruited. 3T hybrid PET/MR scanner where EPI-based and T 1 -weighted sequences were acquired simultaneously with the PET data. Head motion parameters estimated from high temporal resolution MR volumes were used for PET MC. The MR-based MC method was compared to PET frame-based MC methods in which motion parameters were estimated by coregistering 5-minute frames before and after accounting for the attenuation-emission mismatch. The relative changes in standardized uptake value ratios (SUVRs) between the PET volumes processed with the various MC methods, without MC, and the PET volumes with simulated motion were compared in relevant brain regions. The absolute value of the regional SUVR relative change was assessed with pairwise paired t-tests testing at the P = 0.05 level, comparing the values obtained through different MR-based MC processing methods as well as across different motion groups. The intraregion voxelwise variability of regional SUVRs obtained through different MR-based MC processing methods was also assessed with pairwise paired t-tests testing at the P = 0.05 level. MC had a greater impact on PET data quantification in subjects with larger amplitude motion (higher than 18% in the medial orbitofrontal cortex) and greater changes were generally observed for the MR-based MC method compared to the frame-based methods. Furthermore, a mean relative change of ∼4% was observed after MC even at the group level, suggesting the importance of routinely applying this correction. The intraregion voxelwise variability of regional SUVRs was also decreased using MR-based MC. All comparisons were significant at the P = 0.05 level. Incorporating temporally correlated MR data to account for intraframe motion has a positive impact on the FDG PET image quality and data quantification in dementia patients. 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hueso-Gonzalez, F; Vijande, J; Ballester, F
Purpose: Tissue heterogeneities and calcifications have significant impact on the dosimetry of low energy brachytherapy (BT). RayStretch is an analytical algorithm developed in our institution to incorporate heterogeneity corrections in LDR prostate brachytherapy. The aim of this work is to study its application in clinical cases by comparing its predictions with the results obtained with TG-43 and Monte Carlo (MC) simulations. Methods: A clinical implant (71 I-125 seeds, 15 needles) from a real patient was considered. On this patient, different volumes with calcifications were considered. Its properties were evaluated in three ways by i) the Treatment planning system (TPS) (TG-43),more » ii) a MC study using the Penelope2009 code, and iii) RayStretch. To analyse the performance of RayStretch, calcifications located in the prostate lobules covering 11% of the total prostate volume and larger calcifications located in the lobules and underneath the urethra for a total occupied volume of 30% were considered. Three mass densities (1.05, 1.20, and 1.35 g/cm3) were explored for the calcifications. Therefore, 6 different scenarios ranging from small low density calcifications to large high density ones have been discussed. Results: DVH and D90 results given by RayStretch agree within 1% with the full MC simulations. Although no effort has been done to improve RayStretch numerical performance, its present implementation is able to evaluate a clinical implant in a few seconds to the same level of accuracy as a detailed MC calculation. Conclusion: RayStretch is a robust method for heterogeneity corrections in prostate BT supported on TG-43 data. Its compatibility with commercial TPSs and its high calculation speed makes it feasible for use in clinical settings for improving treatment quality. It will allow in a second phase of this project, its use during intraoperative ultrasound planning. This study was partly supported by a fellowship grant from the Spanish Ministry of Education, by the Generalitat Valenciana under Project PROMETEOII/2013/010, by the Spanish Government under Project No. FIS2013-42156 and by the European Commission within the SeventhFramework Program through ENTERVISION (grant agreement number 264552).« less