Protein aggregation studied by forward light scattering and light transmission analysis
NASA Astrophysics Data System (ADS)
Penzkofer, A.; Shirdel, J.; Zirak, P.; Breitkreuz, H.; Wolf, E.
2007-12-01
The aggregation of the circadian blue-light photo-receptor cryptochrome from Drosophila melanogaster (dCry) is studied by transmission and forward light scattering measurement in the protein transparent wavelength region. The light scattering in forward direction is caused by Rayleigh scattering which is proportional to the degree of aggregation. The light transmission through the samples in the transparent region is reduced by Mie light scattering in all directions. It depends on the degree of aggregation and the monomer volume fill factor of the aggregates (less total scattering with decreasing monomer volume fill factor of protein globule) allowing a distinction between tightly packed protein aggregation (monomer volume fill factor 1) and loosely packed protein aggregation (monomer volume fill factor less than 1). An increase in aggregation with temperature, concentration, and blue-light exposure is observed. At a temperature of 4 °C and a protein concentration of less than 0.135 mM no dCry aggregation was observed, while at 24 °C and 0.327 mM gelation occurred (loosely packed aggregates occupying the whole solution volume).
Selber, Jesse C; Wren, James H; Garvey, Patrick B; Zhang, Hong; Erickson, Cameron; Clemens, Mark W; Butler, Charles E
2015-07-01
Acellular dermal matrix for implant-based breast reconstruction appears to cause higher early complication rates, but long-term outcomes are perceived to be superior. This dichotomy is the subject of considerable debate. The authors hypothesized that patient characteristics and operative variables would have a greater impact on complications than the type of acellular dermal matrix used. A retrospective cohort study was performed of consecutive patients who underwent two-stage, implant-based breast reconstruction with human cadaveric or bovine acellular dermal matrix from 2006 to 2012 at a single institution. Patient characteristics and operative variables were analyzed using logistic regression analyses to identify risk factors for complications. The authors included 564 reconstructions in the study. Radiation therapy and obesity increased the odds of all complications. Every 100-ml increase in preoperative breast volume increased the odds of any complication by 1 percent, the odds of infection by 27 percent, and the risk of explantation by 16 percent. The odds of seroma increased linearly with increasing surface area of acellular dermal matrix. Odds of infection were higher with an intraoperative expander fill volume greater than 50 percent of the total volume. Risk of explantation was twice as high when intraoperative expander fill volume was greater than 300 ml. Radiation therapy, obesity, larger breasts, higher intraoperative fill volumes, and larger acellular dermal matrices are all independent risk factors for early complications. Maximizing the initial mastectomy skin envelope fill must be balanced with the understanding that higher complication rates may result from a larger intraoperative breast mound. Risk, III.
Zhou, Kun; Cheng, Qiang; Song, Jinlin; Lu, Lu; Jia, Zhihao; Li, Junwei
2018-01-01
We numerically investigate the broadband perfect infrared absorption by tuning epsilon-near-zero (ENZ) and epsilon-near-pole (ENP) resonances of multilayer indium tin oxide nanowires (ITO NWs). The monolayer ITO NWs array shows intensive absorption at ENZ and ENP wavelengths for p polarization, while only at the ENP wavelength for s polarization. Moreover, the ENP resonances are almost omnidirectional and the ENZ resonances are angularly dependent. Therefore, the absorption bandwidth is broader for p polarization than that for s polarization when polarized waves are incident obliquely. The ENZ resonances can be tuned by altering the doping concentration and volume filling factor of ITO NWs. However, the ENP resonances only can be tuned by changing the doping concentration of ITO NWs, and volume filling factor impacts little on the ENP resonances. Based on the strong absorption properties of each layer at their own ENP and ENZ resonances, the tuned absorption of the bilayer ITO NWs with the different doping concentrations can be broader and stronger. Furthermore, multilayer ITO NWs can achieve broadband perfect absorption by controlling the doping concentration, volume filling factor, and length of the NWs in each layer. This study has the potential to apply to applications requiring efficient absorption and energy conversion.
De Wachter, Stefan; Wyndaele, Jean-Jacques
2008-04-01
To evaluate whether a compelling desire to void (CDV) is always perceived suddenly, or whether it can result from the gradual build-up of bladder-filling sensations. The pattern of filling sensations was evaluated during standard cystometric bladder filling in 75 patients who complained of urgency and showed detrusor overactivity during cystometry. Cystometric filling ended when a CDV was reported. The 'warning volume' is defined as the difference in volume between the first perception of filling and the volume at CDV. Different patterns of bladder-filling sensations were reported. A CDV occurred suddenly, without a preceding sensation in 13% of the patients, whereas 66% reported at least two normal preceding filling sensations before a CDV. The bladder volume at the CDV was significantly smaller in patients that reported no or just one preceding sensation compared with those that reported the normal pattern of two or three sensations (P < 0.005). The bladder volume at which the first filling perception was reported was not different regardless of whether it was described as a first sensation of filling, a first desire or a CDV (P = 0.42). The warning volumes were not different between patients with one or no standardized filling sensations (P = 0.7), but they were significantly smaller than in patients with two or three filling sensations (P = 0.85). A CDV can occur suddenly if normal filling sensation is disturbed, but also gradually if normal filling sensation is preserved. In cases of disturbed filling sensation, the volume at CDV and the warning volume are significantly lower.
The Shock and Vibration Digest. Volume 18, Number 1
1986-01-01
polyurethanes reduced the loss factor and emphasized the correlation between molecular storage modulus by increasing the length of the structure and...one tempera- static deformations. He gave storage and loss ture/frequency range is difficult with copoly- moduli for a carbon black filled and an...has been described (18). The shear loss author states that the frequency dependence of and storage moduli of a void-filled polyurethane the elastomers
Chan, Edwin; Maa, Yuh-Fun; Overcashier, David; Hsu, Chung C
2011-01-01
This study is to investigate the effect of headspace air pressure in pre-filled syringes on liquid leak (dripping) from the syringe needle upon needle shield removal. Drip tests to measure drip quantity were performed on syringes manually filled with 0.5 or 1.0 mL of various aqueous solutions. Parameters assessed included temperature (filling and test), bulk storage conditions (tank pressure and the type of the pressurized gas), solution composition (pure water, 0.9% sodium chloride, and a monoclonal antibody formulation), and testing procedures. A headspace pressure analyzer was used to verify the drip test method. Results suggested that leakage is indeed caused by headspace pressure increase, and the temperature effect (ideal gas expansion) is a major, but not the only, factor. The dissolved gases in the liquid bulk prior to or during filling may contribute to leakage, as these gases could be released into the headspace due to solubility changes (in response to test temperature and pressure conditions) and cause pressure increase. Needle shield removal procedures were found to cause dripping, but liquid composition played little role. Overall, paying attention to the processing history (pressure and temperature) of the liquid bulk is the key to minimize leakage. The headspace pressure could be reduced by decreasing liquid bulk storage pressure, filling at a higher temperature, or employing lower solubility gas (e.g., helium) for bulk transfer and storage. Leakage could also be mitigated by simply holding the syringe needle pointing upward during needle shield removal. Substantial advances in pre-filled syringe technology development, particularly in syringe filling accuracy, have been made. However, there are factors, as subtle as how the needle shield (or tip cap) is removed, that may affect dosing accuracy. We recently found that upon removal of the tip cap from a syringe held vertically with needle pointed downwards, a small amount of solution, up to 3-4% of the 1 mL filled volume or higher for filled volume of <1 mL, leaked out from the needle. This paper identified the root causes of this problem and offered solutions from the perspectives of the syringe fill process and the end user procedure. The readers will benefit from this paper by understanding how each process step prior to and during syringe filling may affect delivery performance of the pre-filled syringe device.
MODELING DISINFECTANT RESIDUALS IN DRINKING-WATER STORAGE TANKS
The factors leading to the loss of disinfectant residual in well-mixed drinking-water storage tanks are studied. Equations relating disinfectant residual to the disinfectant's reation rate, the tank volume, and the fill and drain rates are presented. An analytical solution for ...
Under Pressure: Intraluminal Filling Pressures of Postpartum Hemorrhage Tamponade Balloons
Antony, Kathleen M.; Racusin, Diana A.; Belfort, Michael A.; Dildy, Gary A.
2017-01-01
Objective Uterine tamponade by fluid-filled balloons is now an accepted method of controlling postpartum hemorrhage. Available tamponade balloons vary in design and material, which affects the filling attributes and volume at which they rupture. We aimed to characterize the filling capacity and pressure-volume relationship of various tamponade balloons. Study Design Balloons were filled with water ex vivo. Intraluminal pressure was measured incrementally (every 10 mL for the Foley balloons and every 50 mL for all other balloons). Balloons were filled until they ruptured or until 5,000 mL was reached. Results The Foley balloons had higher intraluminal pressures than the larger-volume balloons. The intraluminal pressure of the Sengstaken-Blakemore tube (gastric balloon) was initially high, but it decreased until shortly before rupture occurred. The Bakri intraluminal pressure steadily increased until rupture occurred at 2,850 mL. The condom catheter, BT-Cath, and ebb all had low intraluminal pressures. Both the BT-Cath and the ebb remained unruptured at 5,000 mL. Conclusion In the setting of acute hemorrhage, expeditious management is critical. Balloons that have a low intraluminal pressure-volume ratio may fill more rapidly, more easily, and to greater volumes. We found that the BT-Cath, the ebb, and the condom catheter all had low intraluminal pressures throughout filling. PMID:28497006
NASA Astrophysics Data System (ADS)
Fassett, C.; Levy, J.; Head, J.
2013-09-01
Landforms inferred to have formed from glacial processes are abundant on Mars and include features such as concentric crater fill (CCF), lobate debris aprons (LDA), and lineated valley fill (LVF). Here, we present new mapping of the spatial extent of these landforms derived from CTX and THEMIS VIS image data, and new geometric constraints on the volume of glaciogenic fill material present in concentric crater fill deposits.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adatepe, M.H.; Nichols, K.; Powell, O.M.
1984-01-01
The authors determined the first third filling fraction (1/3 FF), the maximum filling rate (1/3 FR) and the mean filling rate (1/3 MFR) for the first third diastolic filling period of the left ventricle in patients with coronary artery disease (CAD), valvular heart disease (VHD), pericardial effusion (PE), cardiomyopathies (CM), chronic obstructive lung disease (COPD) and in 5 normals-all from resting gated equilibrium studies. Parameters are calculated from the third order Fourier fit to the LV volume curve and its derivative. 1/3 FF% = 1/3 diastolic count - end systolic count / 1/3 diastolic count x 100. Patients with CADmore » are divided into two groups: Group I with normal ejection fraction (EF) and wall motion (WM); Group II with abnormal EF and WM. Results are shown in the table. Abnormal filling parameters are found not only in CAD but in VHD, PE and CM. The authors conclude that the first third LV filling parameters are sensitive but non-specific indicators of filling abnormalities caused by diverse etiologic factors. Abnormal first third filling parameters may occur in the presence of a normal resting EF and WM in CAD.« less
Azangwe, Godfrey; Grochowska, Paulina; Georg, Dietmar; Izewska, Joanna; Hopfgartner, Johannes; Lechner, Wolfgang; Andersen, Claus E; Beierholm, Anders R; Helt-Hansen, Jakob; Mizuno, Hideyuki; Fukumura, Akifumi; Yajima, Kaori; Gouldstone, Clare; Sharpe, Peter; Meghzifene, Ahmed; Palmans, Hugo
2014-07-01
The aim of the present study is to provide a comprehensive set of detector specific correction factors for beam output measurements for small beams, for a wide range of real time and passive detectors. The detector specific correction factors determined in this study may be potentially useful as a reference data set for small beam dosimetry measurements. Dose response of passive and real time detectors was investigated for small field sizes shaped with a micromultileaf collimator ranging from 0.6 × 0.6 cm(2) to 4.2 × 4.2 cm(2) and the measurements were extended to larger fields of up to 10 × 10 cm(2). Measurements were performed at 5 cm depth, in a 6 MV photon beam. Detectors used included alanine, thermoluminescent dosimeters (TLDs), stereotactic diode, electron diode, photon diode, radiophotoluminescent dosimeters (RPLDs), radioluminescence detector based on carbon-doped aluminium oxide (Al2O3:C), organic plastic scintillators, diamond detectors, liquid filled ion chamber, and a range of small volume air filled ionization chambers (volumes ranging from 0.002 cm(3) to 0.3 cm(3)). All detector measurements were corrected for volume averaging effect and compared with dose ratios determined from alanine to derive a detector correction factors that account for beam perturbation related to nonwater equivalence of the detector materials. For the detectors used in this study, volume averaging corrections ranged from unity for the smallest detectors such as the diodes, 1.148 for the 0.14 cm(3) air filled ionization chamber and were as high as 1.924 for the 0.3 cm(3) ionization chamber. After applying volume averaging corrections, the detector readings were consistent among themselves and with alanine measurements for several small detectors but they differed for larger detectors, in particular for some small ionization chambers with volumes larger than 0.1 cm(3). The results demonstrate how important it is for the appropriate corrections to be applied to give consistent and accurate measurements for a range of detectors in small beam geometry. The results further demonstrate that depending on the choice of detectors, there is a potential for large errors when effects such as volume averaging, perturbation and differences in material properties of detectors are not taken into account. As the commissioning of small fields for clinical treatment has to rely on accurate dose measurements, the authors recommend the use of detectors that require relatively little correction, such as unshielded diodes, diamond detectors or microchambers, and solid state detectors such as alanine, TLD, Al2O3:C, or scintillators.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gasser, U., E-mail: urs.gasser@psi.ch; Hyatt, J. S.; Lietor-Santos, J.-J.
We study the form factor of thermoresponsive microgels based on poly(N-isopropylacrylamide) at high generalized volume fractions, ζ, where the particles must shrink or interpenetrate to fit into the available space. Small-angle neutron scattering with contrast matching techniques is used to determine the particle form factor. We find that the particle size is constant up to a volume fraction roughly between random close packing and space filling. Beyond this point, the particle size decreases with increasing particle concentration; this decrease is found to occur with little interpenetration. Noteworthily, the suspensions remain liquid-like for ζ larger than 1, emphasizing the importance ofmore » particle softness in determining suspension behavior.« less
NASA Astrophysics Data System (ADS)
Deparis, Olivier; Kazansky, Peter G.; Podlipensky, Alexander; Abdolvand, Amin; Seifert, Gerhard; Graener, Heinrich
2006-08-01
The recently discovered poling-assisted bleaching of glass with embedded silver nanoparticles has renewed the interest in thermal poling as a simple, reliable, and low-cost technique for controlling locally the surface-plasmon-resonant optical properties of metal-doped nanocomposite glasses. In the present study, the emphasis is put on the influence of the volume filling factor of metallic clusters on poling-assisted bleaching. Soda-lime silicate glass samples containing spherical silver nanoparticles with a decreasing filling factor across the depth were subject to thermal poling experiments with various poling temperatures, voltages, and times. Optical extinction spectra were measured from ultraviolet to near-infrared ranges and the surface-plasmon-resonant extinction due to silver nanoparticles (around 410nm) was modeled by the Maxwell Garnett [Philos. Trans. R. Soc. London, Ser. A 203, 385 (1904); 205, 237 (1906)] effective medium theory which was adapted in order to take into account the filling factor depth profile. A method was proposed for the retrieval of the filling factor depth profile from optical extinction spectra recorded in fresh and chemically etched samples. A stretched exponential depth profile turned out to be necessary in order to model samples having a high filling factor near the surface. Based on the fact that the electric-field-assisted dissolution of embedded metallic nanoparticles proceeded progressively from the top surface, a bleaching front was defined that moved forward in depth as time elapsed. The position of the bleaching front was determined after each poling experiment by fitting the measured extinction spectrum to the theoretical one. In samples with higher peak value and steeper gradient of the filling factor, the bleaching front reached more rapidly a steady-state depth as poling time increased. Also it increased less strongly with increasing poling voltage. These results were in agreement with the physics of the dissolution process. Finally, clear evidence of injection of hydrogenated ionic species from the atmosphere into the sample during poling was obtained from the growth of the infrared extinction peak associated with OH radicals.
Lépy, M-C; Altzitzoglou, T; Anagnostakis, M J; Capogni, M; Ceccatelli, A; De Felice, P; Djurasevic, M; Dryak, P; Fazio, A; Ferreux, L; Giampaoli, A; Han, J B; Hurtado, S; Kandic, A; Kanisch, G; Karfopoulos, K L; Klemola, S; Kovar, P; Laubenstein, M; Lee, J H; Lee, J M; Lee, K B; Pierre, S; Carvalhal, G; Sima, O; Tao, Chau Van; Thanh, Tran Thien; Vidmar, T; Vukanac, I; Yang, M J
2012-09-01
The second part of an intercomparison of the coincidence summing correction methods is presented. This exercise concerned three volume sources, filled with liquid radioactive solution. The same experimental spectra, decay scheme and photon emission intensities were used by all the participants. The results were expressed as coincidence summing corrective factors for several energies of (152)Eu and (134)Cs, and different source-to-detector distances. They are presented and discussed. Copyright © 2012 Elsevier Ltd. All rights reserved.
Kim, Sue Youn; Kim, Hyeon-Cheol; Shin, Su-Jung; Kim, Euiseong
2018-04-01
The purpose of this study was to evaluate the gap volume between dentin and root-end filling materials. Four root-end filling materials were compared in the present study: ProRoot MTA (PRM; Dentsply Tulsa Dental, Tulsa, OK), MTA Angelus (MAG; Angelus, Londrina, Brazil), EndoCem MTA (ECM; Maruchi, Wonju, Korea), and RetroMTA (RTM; BioMTA, Seoul, Korea). Forty-eight single-rooted, extracted human teeth were instrumented with nickel-titanium instruments and oburated with gutta-percha. The apical 3 mm of the root tip was resected, and root-end preparation was performed with a diamond bur. The root-end cavity was filled with the experimental filling materials for the 4 designated groups (n = 10). Then, the samples were scanned with micro-computed tomographic (micro-CT) imaging. Three-dimensional images of the samples were reconstructed, and the volume of the gap between the tooth surface (dentinal wall) and the root-end filling materials was measured. The percentage volume of the gap between the tooth structure and the root-end filling material (V G %) was calculated. Data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests at a significance level of 95%. The median V G % values for the PRM, MAG, ECM, and RTM groups were 0.00472, 0.00134, 0.00014, and 0.00071, respectively. The ProRoot MTA group showed the greatest gap volume percentage among the experimental groups with a significant statistical difference (P < .05). From the micro-CT analysis, ProRoot MTA had a greater gap volume percentage than other root-end filling materials. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Ver Elst, K; Vermeiren, S; Schouwers, S; Callebaut, V; Thomson, W; Weekx, S
2013-12-01
CLSI recommends a minimal citrate tube fill volume of 90%. A validation protocol with clinical and analytical components was set up to determine the tube fill threshold for international normalized ratio of prothrombin time (PT-INR), activated partial thromboplastin time (aPTT) and fibrinogen. Citrated coagulation samples from 16 healthy donors and eight patients receiving vitamin K antagonists (VKA) were evaluated. Eighty-nine tubes were filled to varying volumes of >50%. Coagulation tests were performed on ACL TOP 500 CTS(®) . Receiver Operating Characteristic (ROC) plot, with Total error (TE) and critical difference (CD) as possible acceptance criteria, was used to determine the fill threshold. Receiving Operating Characteristic was the most accurate with CD for PT-INR and TE for aPTT resulting in thresholds of 63% for PT and 80% for aPTT. By adapted ROC, based on threshold setting at a point of 100% sensitivity at a maximum specificity, CD was best for PT and TE for aPTT resulting in thresholds of 73% for PT and 90% for aPTT. For fibrinogen, the method was only valid with the TE criterion at a 63% fill volume. In our study, we validated the minimal citrate tube fill volumes of 73%, 90% and 63% for PT-INR, aPTT and fibrinogen, respectively. © 2013 John Wiley & Sons Ltd.
A carbon nanotube filled polydimethylsiloxane hybrid membrane for enhanced butanol recovery
Xue, Chuang; Du, Guang-Qing; Chen, Li-Jie; Ren, Jian-Gang; Sun, Jian-Xin; Bai, Feng-Wu; Yang, Shang-Tian
2014-01-01
The carbon nanotubes (CNTs) filled polydimethylsiloxane (PDMS) hybrid membrane was fabricated to evaluate its potential for butanol recovery from acetone-butanol-ethanol (ABE) fermentation broth. Compared with the homogeneous PDMS membrane, the CNTs filled into the PDMS membrane were beneficial for the improvement of butanol recovery in butanol flux and separation factor. The CNTs acting as sorption-active sites with super hydrophobicity could give an alternative route for mass transport through the inner tubes or along the smooth surface. The maximum total flux and butanol separation factor reached up to 244.3 g/m2·h and 32.9, respectively, when the PDMS membrane filled with 10 wt% CNTs was used to separate butanol from the butanol/water solution at 80°C. In addition, the butanol flux and separation factor increased dramatically as temperature increased from 30°C to 80°C in feed solution since the higher temperature produced more free volumes in polymer chains to facilitate butanol permeation. A similar increase was also observed when butanol titer in solution increased from 10 g/L to 25 g/L. Overall, the CNTs/PDMS hybrid membrane with higher butanol flux and selectivity should have good potential for pervaporation separation of butanol from ABE fermentation broth. PMID:25081019
Vasilev, Nikolay; Schmitz, Christian; Grömping, Ulrike; Fischer, Rainer; Schillberg, Stefan
2014-01-01
A large-scale statistical experimental design was used to determine essential cultivation parameters that affect biomass accumulation and geraniol production in transgenic tobacco (Nicotiana tabacum cv. Samsun NN) cell suspension cultures. The carbohydrate source played a major role in determining the geraniol yield and factors such as filling volume, inoculum size and light were less important. Sucrose, filling volume and inoculum size had a positive effect on geraniol yield by boosting growth of plant cell cultures whereas illumination of the cultures stimulated the geraniol biosynthesis. We also found that the carbohydrates sucrose and mannitol showed polarizing effects on biomass and geraniol accumulation. Factors such as shaking frequency, the presence of conditioned medium and solubilizers had minor influence on both plant cell growth and geraniol content. When cells were cultivated under the screened conditions for all the investigated factors, the cultures produced ∼5.2 mg/l geraniol after 12 days of cultivation in shaking flasks which is comparable to the yield obtained in microbial expression systems. Our data suggest that industrial experimental designs based on orthogonal arrays are suitable for the selection of initial cultivation parameters prior to the essential medium optimization steps. Such designs are particularly beneficial in the early optimization steps when many factors must be screened, increasing the statistical power of the experiments without increasing the demand on time and resources. PMID:25117009
Vasilev, Nikolay; Schmitz, Christian; Grömping, Ulrike; Fischer, Rainer; Schillberg, Stefan
2014-01-01
A large-scale statistical experimental design was used to determine essential cultivation parameters that affect biomass accumulation and geraniol production in transgenic tobacco (Nicotiana tabacum cv. Samsun NN) cell suspension cultures. The carbohydrate source played a major role in determining the geraniol yield and factors such as filling volume, inoculum size and light were less important. Sucrose, filling volume and inoculum size had a positive effect on geraniol yield by boosting growth of plant cell cultures whereas illumination of the cultures stimulated the geraniol biosynthesis. We also found that the carbohydrates sucrose and mannitol showed polarizing effects on biomass and geraniol accumulation. Factors such as shaking frequency, the presence of conditioned medium and solubilizers had minor influence on both plant cell growth and geraniol content. When cells were cultivated under the screened conditions for all the investigated factors, the cultures produced ∼ 5.2 mg/l geraniol after 12 days of cultivation in shaking flasks which is comparable to the yield obtained in microbial expression systems. Our data suggest that industrial experimental designs based on orthogonal arrays are suitable for the selection of initial cultivation parameters prior to the essential medium optimization steps. Such designs are particularly beneficial in the early optimization steps when many factors must be screened, increasing the statistical power of the experiments without increasing the demand on time and resources.
Heiser, Brian; Okrasinski, E B; Murray, Rebecca; McCord, Kelly
The initial negative pressures of evacuated blood collection tubes (EBCT) and their in vitro performance as a rigid closed-suction surgical drain (CSSD) reservoir has not been evaluated in the scientific literature despite being described in both human and veterinary texts and journals. The initial negative pressures of EBCT sized 3, 6, 10, and 15 mL were measured and the stability of the system monitored. The pressure-to-volume curve as either air or water was added and maximal filling volumes were measured. Evacuated blood collection tubes beyond the manufacture's expiration date were evaluated for initial negative pressures and maximal filling volumes. Initial negative pressure ranged from -214 mm Hg to -528 mm Hg for EBCT within the manufacturer's expiration date. Different pressure-to-volume curves were found for air versus water. Optimal negative pressures of CSSD are debated in the literature. Drain purpose and type of exudates are factors that should be considered when deciding which EBCT size to implement. Evacuated blood collection tubes have a range of negative pressures and pressure-to-volume curves similar to previously evaluated CSSD rigid reservoirs. Proper drain management and using EBCT within labeled expiration date are important to ensure that expected negative pressures are generated.
Measuring the fraction of pool volume filled with fine sediment
Sue Hilton; Thomas E. Lisle
1993-01-01
The fraction of pool volume filled with fine sediment (usually fine sand to medium gravel) can be a useful index of the sediment supply and substrate habitat of gravel-bed channels. It can be used to evaluate and monitor channel condition and to detect and evaluate sediment sources. This fraction (V*) is the ratio of fine-sediment volume to pool water volume plus fine-...
Rechenberg, D K; Paqué, F
2013-06-01
To assess the impact of cross-sectional root canal shape (CSRCS) on the canal volume that can be filled and the root filling material that remains following a subsequent retreatment procedure. A total of 15 extracted two-rooted human maxillary premolars and 15 mandibular first molars were used. Both root canals in the premolars (N = 30) and the distal root canal in the molars (N = 15) were prepared using ProFile instruments and filled by lateral compaction using gutta-percha and AH Plus sealer. Canals were later retreated using the last ProFile used for instrumentation followed by two ProFiles of increasing size. Teeth were viewed in a μCT scanner before and after each treatment step. Defined and validated threshold levels were used to differentiate empty root canal volumes, root dentine and root filling materials from each other. CSRCS was defined as the averaged ratio between bucco-lingual and mesio-distal canal diameter (round ≤ 1, oval 1-2, long oval 2-4 and flattened ≥ 4), determined for each 1 mm over the total root length. Data were averaged between the two canals in premolars, only the distal canals were assessed in molars. Parametric and non-parametric tests were used to statistically compare the data, alpha = 0.01. Canals in premolars had a round CSRCS after preparation (1.0 ± 0.0), whereas distal counterparts in molars were oval (1.6 ± 0.5). Significantly (P < 0.01) more canal volume could be filled, and significantly less filling material remained after retreatment in premolars compared with mandibular molar distal canals. There was a high correlation between CSRCS, filled canal volume and remaining filling material. The endodontic procedures under investigation were significantly influenced by the cross-sectional root canal shape. © 2012 International Endodontic Journal. Published by Blackwell Publishing Ltd.
30 CFR 250.514 - Well-control fluids, equipment, and operations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... uppermost BOP; (2) A well-control, fluid-volume measuring device for determining fluid volumes when filling the hole on trips; and (3) A recording mud-pit-level indicator to determine mud-pit-volume gains and... the hole with drill pipe, the annulus shall be filled with well-control fluid before the change in...
Kumar, B; Han, L-F; Wassenaar, L I; Klaus, P M; Kainz, G G; Hillegonds, D; Brummer, D; Ahmad, M; Belachew, D L; Araguás, L; Aggarwal, P
2016-12-01
Tritium ( 3 H) in natural waters is a powerful tracer of hydrological processes, but its low concentrations require electrolytic enrichment before precise measurements can be made with a liquid scintillation counter. Here, we describe a newly developed, compact tritium enrichment unit which can be used to enrich up to 2L of a water sample. This allows a high enrichment factor (>100) for measuring low 3 H contents of <0.05TU. The TEU uses a small cell (250mL) with automated re-filling and a CO 2 bubbling technique to neutralize the high alkalinity of enriched samples. The enriched residual sample is retrieved from the cell under vacuum by cryogenic distillation at -20°C and the tritium enrichment factor for each sample is accurately determined by measuring pre- and post- enrichment 2 H concentrations with laser spectrometry. Copyright © 2016. Published by Elsevier Ltd.
Accurate GM atrophy quantification in MS using lesion-filling with co-registered 2D lesion masks☆
Popescu, V.; Ran, N.C.G.; Barkhof, F.; Chard, D.T.; Wheeler-Kingshott, C.A.; Vrenken, H.
2014-01-01
Background In multiple sclerosis (MS), brain atrophy quantification is affected by white matter lesions. LEAP and FSL-lesion_filling, replace lesion voxels with white matter intensities; however, they require precise lesion identification on 3DT1-images. Aim To determine whether 2DT2 lesion masks co-registered to 3DT1 images, yield grey and white matter volumes comparable to precise lesion masks. Methods 2DT2 lesion masks were linearly co-registered to 20 3DT1-images of MS patients, with nearest-neighbor (NNI), and tri-linear interpolation. As gold-standard, lesion masks were manually outlined on 3DT1-images. LEAP and FSL-lesion_filling were applied with each lesion mask. Grey (GM) and white matter (WM) volumes were quantified with FSL-FAST, and deep gray matter (DGM) volumes using FSL-FIRST. Volumes were compared between lesion mask types using paired Wilcoxon tests. Results Lesion-filling with gold-standard lesion masks compared to native images reduced GM overestimation by 1.93 mL (p < .001) for LEAP, and 1.21 mL (p = .002) for FSL-lesion_filling. Similar effects were achieved with NNI lesion masks from 2DT2. Global WM underestimation was not significantly influenced. GM and WM volumes from NNI, did not differ significantly from gold-standard. GM segmentation differed between lesion masks in the lesion area, and also elsewhere. Using the gold-standard, FSL-FAST quantified as GM on average 0.4% of the lesion area with LEAP and 24.5% with FSL-lesion_filling. Lesion-filling did not influence DGM volumes from FSL-FIRST. Discussion These results demonstrate that for global GM volumetry, precise lesion masks on 3DT1 images can be replaced by co-registered 2DT2 lesion masks. This makes lesion-filling a feasible method for GM atrophy measurements in MS. PMID:24567908
NASA Astrophysics Data System (ADS)
Kim, Jae-Sung; Chung, Jin-Beom; Kim, In-Ah; Eom, Keun-Yong
2013-10-01
We used an endorectal balloon (ERB) for prostate immobilization during intensity-modulated radiotherapy (IMRT) for prostate cancer treatment. To investigate the dosimetric effects of ERB-filling materials, we changed the ERB Hounsfield unit (HU) from 0 to 1000 HU in 200-HU intervals to simulate the various ERB fillings; 0 HU simulated a water-filled ERB, and 1000 HU simulated the densest material-filled ERB. Dosimetric data (coverage, homogeneity, conformity, maximal dose, and typical volume dose) for the tumor and the organs at risk (OARs) were evaluated in prostate IMRT treatment plans with 6-MV and 15-MV beams. The tumor coverage appeared to differ by approximately 1%, except for the clinical target volume (CTV) V100% and the planning target volume (PTV) V100%. The largest difference for the various ERB fillings was observed in the PTV V100%. In spite of increasing HU, the prostate IMRT plans at both energies had relatively low dosimetric effects on the PTV and the CTV. However, the maximal and the typical volume doses (D25%, D30%, and D50%) to the rectal wall and the bladder increased with increasing HU. For an air-filled ERB, the maximal doses to the rectal wall and the monitor units were lower than the corresponding values for the water-filled and the densest material-filled ERBs. An air-filled ERB spared the rectal wall because of its dosimetric effect. Thus, we conclude that the use of an air-filled ERB provides a dosimetric benefit to the rectal wall without a loss of target coverage and is an effective option for prostate IMRT treatment.
21 CFR 100.100 - Misleading containers.
Code of Federal Regulations, 2010 CFR
2010-04-01
... nonfunctional slack-fill. Slack-fill is the difference between the actual capacity of a container and the volume of product contained therein. Nonfunctional slack-fill is the empty space in a package that is filled...
30 CFR 250.514 - Well-control fluids, equipment, and operations.
Code of Federal Regulations, 2012 CFR
2012-07-01
...-control, fluid-volume measuring device for determining fluid volumes when filling the hole on trips; and... shall include both a visual and an audible warning device. (c) When coming out of the hole with drill... collars that may be pulled prior to filling the hole and the equivalent well-control fluid volume shall be...
Determinants of immediate price impacts at the trade level in an emerging order-driven market
NASA Astrophysics Data System (ADS)
Zhou, Wei-Xing
2012-02-01
Common wisdom argues that, in general, large trades cause large price changes, whereas small trades cause small price changes. However, for extremely large price changes, the trade size and news play a minor role, while liquidity (especially price gaps on the limit order book) is a more influential factor. Hence, there might be other factors influencing the immediate price impacts of trades. In this paper, through mechanical analysis of price variations before and after a trade of arbitrary size, we identify that the trade size, the bid-ask spread, the price gaps and the outstanding volumes at the bid and ask sides of the limit order book have an impact on the changes in prices. We propose two regression models to investigate the influence of these microscopic factors on the price impact of buyer-initiated partially filled trades, seller-initiated partially filled trades, buyer-initiated filled trades and seller-initiated filled trades. We find that they have quantitatively similar explanatory powers and these factors can account for up to 44% of the price impacts. Large trade sizes, wide bid-ask spreads, high liquidity at the same side and low liquidity at the opposite side will cause a large price impact. We also find that the liquidity at the opposite side has a more influential impact than the liquidity at the same side. Our results shed new light on the determinants of immediate price impacts.
Impact of gastric filling on radiation dose delivered to gastroesophageal junction tumors.
Bouchard, Myriam; McAleer, Mary Frances; Starkschall, George
2010-05-01
This study examined the impact of gastric filling variation on target coverage of gastroesophageal junction (GEJ) tumors in three-dimensional conformal radiation therapy (3DCRT), intensity-modulated radiation therapy (IMRT), or IMRT with simultaneous integrated boost (IMRT-SIB) plans. Eight patients previously receiving radiation therapy for esophageal cancer had computed tomography (CT) datasets acquired with full stomach (FS) and empty stomach (ES). We generated treatment plans for 3DCRT, IMRT, or IMRT-SIB for each patient on the ES-CT and on the FS-CT datasets. The 3DCRT and IMRT plans were planned to 50.4 Gy to the clinical target volume (CTV), and the same for IMRT-SIB plus 63.0 Gy to the gross tumor volume (GTV). Target coverage was evaluated using dose-volume histogram data for patient treatments simulated with ES-CT sets, assuming treatment on an FS for the entire course, and vice versa. FS volumes were a mean of 3.3 (range, 1.7-7.5) times greater than ES volumes. The volume of the GTV receiving >or=50.4 Gy (V(50.4Gy)) was 100% in all situations. The planning GTV V(63Gy) became suboptimal when gastric filling varied, regardless of whether simulation was done on the ES-CT or the FS-CT set. Stomach filling has a negligible impact on prescribed dose delivered to the GEJ GTV, using either 3DCRT or IMRT planning. Thus, local relapses are not likely to be related to variations in gastric filling. Dose escalation for GEJ tumors with IMRT-SIB may require gastric filling monitoring.
Effect of tank geometry on its average performance
NASA Astrophysics Data System (ADS)
Orlov, Aleksey A.; Tsimbalyuk, Alexandr F.; Malyugin, Roman V.; Leontieva, Daria A.; Kotelnikova, Alexandra A.
2018-03-01
The mathematical model of non-stationary filling of vertical submerged tanks with gaseous uranium hexafluoride is presented in the paper. There are calculations of the average productivity, heat exchange area, and filling time of various volumes tanks with smooth inner walls depending on their "height : radius" ratio as well as the average productivity, degree, and filling time of horizontal ribbing tank with volume 6.10-2 m3 with change central hole diameter of the ribs. It has been shown that the growth of "height / radius" ratio in tanks with smooth inner walls up to the limiting values allows significantly increasing tank average productivity and reducing its filling time. Growth of H/R ratio of tank with volume 1.0 m3 to the limiting values (in comparison with the standard tank having H/R equal 3.49) augments tank productivity by 23.5 % and the heat exchange area by 20%. Besides, we have demonstrated that maximum average productivity and a minimum filling time are reached for the tank with volume 6.10-2 m3 having central hole diameter of horizontal ribs 6.4.10-2 m.
Huang, Jia; Luo, Qingquan; Shentu, Yang; Zhao, Xiaojing
2010-10-01
The aim of this study is to analyze the impact on the cough after radical systematic mediastinal lymphadenectomy and prevention of refractory cough with mediastinal fat to fill the residual cavity after radical systematic mediastinal lymphadenectomy. Sixty patients clinically diagnosed of lung cancer were selected according to the adopt standardization, from January 2008 to December 2008. All of the patients were divided into two groups randomly: the filling-fat group and the non-filling-fat group. The surgical information such as operation duration time bleeding volume during operation, post-operation bleeding volume were recorded. After one month, FACT-L and LCQ were completed. There are no remarkably differences between the operation duration time, bleeding volume in operation and 1st postoperation day's drainage volume of the two groups. There's significant difference in the scores of cough at night after taking off the chest tube, as well as in the scores of LCQ after one month and in the scores of last items of FACT-L. Filling the fat of the mediastinal to cover the residual cavity left by completely systematic mediastinal lymphadenectomy can reduce the refractory cough after surgery, and can also improve the quality of the life. It has no effect on the the operation duration time, bleeding volume in operation and 1st post-operation day's drainage volume of the patients.
Shigemi, Kenji
2016-05-01
To maintain proper cardiac preload is one of the most effective procedures for the systemic circulation remaining stable. In particular, the balance between vascular capacity and total blood volume must be maintained within appropriate range by the administration of fluids, blood and/or vasoactive drugs with mean circulatory filling pressure (Pmcf), central venous pressure (CVP) or stroke volume variation (SVV). End-diastolic left ventricular volume (Ved) is theoretically the best index of cardiac preload; however, without transesophageal echocardbalanceiogram we cannot directly monitor Ved during anesthesia. The infused fluid volume remaining in intravascular space, the vascular capacity controlled by autonomic nervous system and/or vasoactive agents, and the unstressed blood volume properly mobilized to excess blood volume are the crucial factors to maintain cardiac output The knowledge of vascular physiology contribute the decision making to manipulate such factors to control blood circulation during general anesthesia. For example, CVP is usually maintained in the narrow range and seems to be stable; however, it must be changed just after the circulatory disturbances, such as acute bleeding, blood transfusion, and fluid infusion, and followed by gradual returning to initial value, because of the solid mechanism to preserve cardiac output
Restoring sediment to compensate for human-induced erosion of an estuarine shore
NASA Astrophysics Data System (ADS)
Nordstrom, Karl F.; Jackson, Nancy L.; Farrell, Eugene J.; Rafferty, Patricia; Tengwall, Charles
2016-06-01
Shoreline erosion is often exacerbated by reduction of sediment inputs because of interference with sediment transport by human structures. We evaluate use of sediment dredged from a navigation channel to establish a feeder beach adjacent to a bulkhead as a solution for addressing erosion of landforms and habitats on sandy estuarine shores. The objectives are to determine how beach volume, position and shape within and downdrift of the fill area change and whether the volumes supplied by dredging match sediment losses caused by human actions. The fill was placed along a 75 m length of shoreline adjacent to a marina in Great South Bay at Fire Island, New York, USA. Changes in beach shape and volume were determined from topographic surveys conducted before and after fill and at half year intervals for 18 months. The quantity of fill was 1747 m3. Maximum shoreline advance due to fill emplacement was 20.7 m. The maximum volume placed at any transect was 28.6 m3 m- 1 of shoreline length. Erosion of the fill occurred rapidly, with landward migration of a conspicuous scarp. The edge of the upland 18 months after the fill was placed was up to 4.6 m farther landward than prior to the fill. Movement of sediment alongshore downdrift of the fill occurred as wave-like pulses, extending the active foreshore bayward, causing accretion of the inner low tide terrace, burying saltmarsh peat outcrops on the foreshore and creating a higher and wider overwash platform over portions of the saltmarshes. Landforms downdrift of the fill area underwent successive stages including erosion (pre-nourishment), accretion, stability (with throughput of sediment) and then erosion. Beach nourishment compensates for human-induced sediment losses. The volume of sediment added from maintenance dredging can slow the rate of erosion but may not prevent long-term shoreline retreat. Restoration and maintenance of coastal landforms and habitats to specific target states at a given location is difficult, but augmenting longshore sediment inputs can allow those locations to undergo cycles of erosion and accretion, creating a variety of landforms and habitats where only erosional forms existed previously. Alternatively, nourishment could occur more frequently and in smaller volumes to reduce fluctuations in accretion-erosion cycles.
Annotated Bibliography for Lake Erie. Volume IV. Physical,
1974-10-01
Presque Isle Bay, Erie , Pennsylvania - interim report. Environ- mental Sciences Inc. Pittsburg, Pa. 235 P. The factors... Presque Isle Peninsula, Erie , Pennsylvania , indicates apparent correlation of initial high erosion rates of placed beach fill with sand size character...changes since 1854. (CE) 777. U. S. Army Corps of Engineers. 1960. Presque Isle Peninsula, Erie , Pennsylvania , beach erosion con- trol study.
Gating geometry studies of thin-walled 17-4PH investment castings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maguire, M.C.; Zanner, F.J.
1992-11-01
The ability to design gating systems that reliably feed and support investment castings is often the result of ``cut-and-try`` methodology. Factors such as hot tearing, porosity, cold shuts, misruns, and shrink are defects often corrected by several empirical gating design iterations. Sandia National Laboratories is developing rules that aid in removing the uncertainty involved in the design of gating systems for investment castings. In this work, gating geometries used for filling of thin walled investment cast 17-4PH stainless steel flat plates were investigated. A full factorial experiment evaluating the influence of metal pour temperature, mold preheat temperature, and mold channelmore » thickness were conducted for orientations that filled a horizontal flat plate from the edge. A single wedge gate geometry was used for the edge-gated configuration. Thermocouples placed along the top of the mold recorded metal front temperatures, and a real-time x-ray imaging system tracked the fluid flow behavior during filling of the casting. Data from these experiments were used to determine the terminal fill volumes and terminal fill times for each gate design.« less
Gating geometry studies of thin-walled 17-4PH investment castings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maguire, M.C.; Zanner, F.J.
1992-01-01
The ability to design gating systems that reliably feed and support investment castings is often the result of cut-and-try'' methodology. Factors such as hot tearing, porosity, cold shuts, misruns, and shrink are defects often corrected by several empirical gating design iterations. Sandia National Laboratories is developing rules that aid in removing the uncertainty involved in the design of gating systems for investment castings. In this work, gating geometries used for filling of thin walled investment cast 17-4PH stainless steel flat plates were investigated. A full factorial experiment evaluating the influence of metal pour temperature, mold preheat temperature, and mold channelmore » thickness were conducted for orientations that filled a horizontal flat plate from the edge. A single wedge gate geometry was used for the edge-gated configuration. Thermocouples placed along the top of the mold recorded metal front temperatures, and a real-time x-ray imaging system tracked the fluid flow behavior during filling of the casting. Data from these experiments were used to determine the terminal fill volumes and terminal fill times for each gate design.« less
External cardiac compression may be harmful in some scenarios of pulseless electrical activity.
Hogan, T S
2012-10-01
Pulseless electrical activity occurs when organised or semi-organised electrical activity of the heart persists but the product of systemic vascular resistance and the increase in systemic arterial flow generated by the ejection of the left venticular stroke volume is not sufficient to produce a clinically detectable pulse. Pulseless electrical activity encompasses a very heterogeneous variety of severe circulatory shock states ranging in severity from pseudo-cardiac arrest to effective cardiac arrest. Outcomes of cardiopulmonary resuscitation for pulseless electrical activity are generally poor. Impairment of cardiac filling is the limiting factor to cardiac output in many scenarios of pulseless electrical activity, including extreme vasodilatory shock states. There is no evidence that external cardiac compression can increase cardiac output when impaired cardiac filling is the limiting factor to cardiac output. If impaired cardiac filling is the limiting factor to cardiac output and the heart is effectively ejecting all the blood returning to it, then external cardiac compression can only increase cardiac output if it increases venous return and cardiac filling. Repeated cardiac compression asynchronous with the patient's cardiac cycle and raised mean intrathoracic pressure due to chest compression can be expected to reduce rather than to increase cardiac filling and therefore to reduce rather than to increase cardiac output in such circumstances. The hypothesis is proposed that the performance of external cardiac compression will have zero or negative effect on cardiac output in pulseless electrical activity when impaired cardiac filling is the limiting factor to cardiac output. External cardiac compression may be both directly and indirectly harmful to significant sub-groups of patients with pulseless electrical activity. We have neither evidence nor theory to provide comfort that external cardiac compression is not harmful in many scenarios of pulseless electrical activity. Investigation using a variety of animal models of pulseless electrical activity produced by different shock-inducing mechanisms is required to provide an evidence base for resuscitation guidelines. Copyright © 2012 Elsevier Ltd. All rights reserved.
Zhang, Qun; Lin, Shi-Rong; He, Fang; Kang, De-Hua; Chen, Guo-Zhang; Luo, Wei
2011-11-01
Postoperative radiotherapy is a major treatment for patients with maxillary sinus carcinoma. However, the irregular resection cavity poses a technical difficulty for this treatment, causing uneven dose distribution to target volumes. In this study, we evaluated the dose distribution to target volumes and normal tissues in postoperative intensity-modulated radiotherapy (IMRT) after placing a water-filled balloon into the resection cavity. Three postoperative patients with advanced maxillary sinus carcinoma were selected in this trial. Water-filled balloons and supporting dental stents were fabricated according to the size of the maxillary resection cavity. Simulation CT scans were performed with or without water-filled balloons, IMRT treatment plans were established, and dose distribution to target volumes and organs at risk were evaluated. Compared to those in the treatment plan without balloons, the dose (D98) delivered to 98% of the gross tumor volume (GTV) increased by 2.1 Gy (P = 0.009), homogeneity index (HI) improved by 2.3% (P = 0.001), and target volume conformity index (TCI) of 68 Gy increased by 18.5% (P = 0.011) in the plan with balloons. Dosimetry endpoints of normal tissues around target regions in both plans were not significantly different (P > 0.05) except for the optic chiasm. In the plan without balloons, 68 Gy high-dose regions did not entirely cover target volumes in the ethmoid sinus, posteromedial wall of the maxillary sinus, or surgical margin of the hard palate. In contrast, 68 Gy high-dose regions entirely covered the GTV in the plan with balloons. These results suggest that placing a water-filled balloon in the resection cavity for postoperative IMRT of maxillary sinus carcinoma can reduce low-dose regions and markedly and simultaneously increase dose homogeneity and conformity of target volumes.
Particulate and microbial contamination in in-use admixed intravenous infusions.
Yorioka, Katsuhiro; Oie, Shigeharu; Oomaki, Masafumi; Imamura, Akihisa; Kamiya, Akira
2006-11-01
We compared particulate and microbial contamination in residual solutions of peripheral intravenous admixtures after the termination of drip infusion between intravenous fluids admixed with glass ampoule drugs and those admixed with pre-filled syringe drugs. The mean number of particles>or=1.3 microm in diameter per 1 ml of residual solution was 758.4 for fluids (n=60) admixed with potassium chloride in a glass ampoule (20 ml volume), 158.6 for fluids (n=63) admixed with potassium chloride in a pre-filled syringe (20 ml volume), 736.5 for fluids (n=66) admixed with sodium chloride in a glass ampoule (20 ml volume), 179.2 for fluids (n=15) admixed with sodium chloride in a pre-filled syringe (20 ml volume), 1884.5 in fluids (n=30) admixed with dobutamine hydrochloride in 3 glass ampoules (5 ml volume), and 178.9 (n=10) in diluted dobutamine hydrochloride in pre-filled syringes (50 ml volume: For these samples alone, particulate and microbial contamination were evaluated in sealed products.) Thus, for potassium chloride or sodium chloride for injection, the number of particles>or=1.3 microm in diameter in the residual intravenous solution was significantly higher for fluids admixed with glass ampoule drugs than for those admixed with pre-filled syringe drugs (p<0.0001). For dobutamine hydrochloride for injection, the number of particles>or=1.3 microm in diameter in the residual intravenous solution was estimated to be higher for fluids admixed with its glass ampoule drug than for those admixed with its pre-filled syringe drug. Observation of the residual solutions of fluids admixed with potassium chloride, sodium chloride, or dobutamine hydrochloride in glass ampoules using an electron microscope with an X-ray analyzer showed glass fragments in each residual solution. Therefore, for the prevention of glass particle contamination in peripheral intravenous admixtures, the use of pre-filled syringe drugs may a useful method. No microbial contamination was observed in any of the residual solutions of 5 types of admixture.
Dall'Agnol, Cristina; Hartmann, Mateus Silveira Martins; Barletta, Fernando Branco
2008-01-01
This study evaluated the efficiency of different techniques for removal of filling material from root canals, using computed tomography (CT). Sixty mesial roots from extracted human mandibular molars were used. Root canals were filled and, after 6 months, the teeth were randomly assigned to 3 groups, according to the root-filling removal technique: Group A - hand instrumentation with K-type files; Group B - reciprocating instrumentation with engine-driven K-type files; and Group C rotary instrumentation with engine-driven ProTaper system. CT scans were used to assess the volume of filling material inside the root canals before and after the removal procedure. In both moments, the area of filling material was outlined by an experienced radiologist and the volume of filling material was automatically calculated by the CT software program. Based on the volume of initial and residual filling material of each specimen, the percentage of filling material removed from the root canals by the different techniques was calculated. Data were analyzed statistically by ANOVA and chi-square test for linear trend (?=0.05). No statistically significant difference (p=0.36) was found among the groups regarding the percent means of removed filling material. The analysis of the association between the percentage of filling material removal (high or low) and the proposed techniques by chi-square test showed statistically significant difference (p=0.015), as most cases in group B (reciprocating technique) presented less than 50% of filling material removed (low percent removal). In conclusion, none of the techniques evaluated in this study was effective in providing complete removal of filling material from the root canals.
Lord, Rachel; MacLeod, David; George, Keith; Oxborough, David; Shave, Rob; Stembridge, Mike
2018-04-01
What is the central question of this study? A reduction in left ventricular (LV) filling, and concomitant increase in heart rate, augments LV mechanics to maintain stroke volume (SV); however, the impact of reduced LV filling in isolation on SV and LV mechanics is currently unknown. What is the main finding and its importance? An isolated decrease in LV filling did not provoke a compensatory increase in mechanics to maintain SV; in contrast, LV mechanics and SV were reduced. These data indicate that when LV filling is reduced without changes in heart rate, LV mechanics do not compensate to maintain SV. An acute non-invasive reduction in preload has been shown to augment cardiac mechanics to maintain stroke volume and cardiac output. Such interventions induce concomitant changes in heart rate, whereas blood volume extraction reduces preload without changes in heart rate. Therefore, the purpose of this study was to determine whether a preload reduction in isolation resulted in augmented stroke volume achieved via enhanced cardiac mechanics. Nine healthy volunteers (four female, age 29 ± 11 years) underwent echocardiography for the assessment of left ventricular (LV) volumes and mechanics in a supine position at baseline and end extraction after the controlled removal of 25% of total blood volume (1062 ± 342 ml). Arterial blood pressure was monitored continuously by a pressure transducer attached to an indwelling radial artery catheter. Heart rate and total peripheral resistance were unchanged from baseline to end extraction, but systolic blood pressure was reduced (from 148 to 127 mmHg). From baseline to end extraction there were significant reductions in left ventricular end-diastolic volume (from 89 to 71 ml) and stroke volume (from 56 to 37 ml); however, there was no change in LV twist, basal or apical rotation. In contrast, LV longitudinal strain (from -20 to -17%) and basal circumferential strain (from -22 to -19%) were significantly reduced from baseline to end extraction. In conclusion, a reduction in preload during blood volume extraction does not result in compensatory changes in stroke volume or cardiac mechanics. Our data suggest that LV strain is dependent on LV filling and consequent geometry, whereas LV twist could be mediated by heart rate. © 2018 The Authors. Experimental Physiology © 2018 The Physiological Society.
RIGHT AND LEFT VENTRICULAR DIASTOLIC PRESSURE–VOLUME RELATIONS: A COMPREHENSIVE REVIEW
Pasipoularides, Ares
2012-01-01
Ventricular compliance alterations can affect cardiac performance and adaptations. Moreover, diastolic mechanics are important in assessing both diastolic and systolic function, since any filling impairment can compromise systolic function. A sigmoidal passive filling pressure-volume relationship, developed using chronically instrumented, awake-animal disease models, is clinically adaptable to evaluating diastolic dynamics using subject-specific micromanometric and volumetric data from the entire filling period of any heartbeat(s). This innovative relationship is the global, integrated expression of chamber geometry, wall thickness, and passive myocardial wall properties. Chamber and myocardial compliance curves of both ventricles can be computed by the sigmoidal methodology over the entire filling period and plotted over appropriate filling pressure ranges. Important characteristics of the compliance curves can be examined and compared between the right and the left ventricle, and for different physiological and pathological conditions. The sigmoidal paradigm is more accurate and, therefore, a better alternative to the conventional exponential pressure-volume approximation. PMID:23179133
Sun, Jirun; Eidelman, Naomi; Lin-Gibson, Sheng
2009-03-01
The objectives of this study were to (1) demonstrate X-ray micro-computed tomography (microCT) as a viable method for determining the polymerization shrinkage and microleakage on the same sample accurately and non-destructively, and (2) investigate the effect of sample geometry (e.g., C-factor and volume) on polymerization shrinkage and microleakage. Composites placed in a series of model cavities of controlled C-factors and volumes were imaged using microCT to determine their precise location and volume before and after photopolymerization. Shrinkage was calculated by comparing the volume of composites before and after polymerization and leakage was predicted based on gap formation between composites and cavity walls as a function of position. Dye penetration experiments were used to validate microCT results. The degree of conversion (DC) of composites measured using FTIR microspectroscopy in reflectance mode was nearly identical for composites filled in all model cavity geometries. The shrinkage of composites calculated based on microCT results was statistically identical regardless of sample geometry. Microleakage, on the other hand, was highly dependent on the C-factor as well as the composite volume, with higher C-factors and larger volumes leading to a greater probability of microleakage. Spatial distribution of microleakage determined by microCT agreed well with results determined by dye penetration. microCT has proven to be a powerful technique in quantifying polymerization shrinkage and corresponding microleakage for clinically relevant cavity geometries.
NASA Astrophysics Data System (ADS)
Kothe, Stefan; Güttler, Carsten; Blum, Jürgen
2010-12-01
In recent years, a number of new experiments have advanced our knowledge on the early growth phases of protoplanetary dust aggregates. Some of these experiments have shown that collisions between porous and compacted agglomerates at velocities above the fragmentation threshold velocity can lead to growth of the compact body, when the porous collision partner fragments upon impact and transfers mass to the compact agglomerate. To obtain a deeper understanding of this potentially important growth process, we performed laboratory and drop tower experiments to study multiple impacts of small, highly porous dust-aggregate projectiles onto sintered dust targets. The projectile and target consisted of 1.5 μm monodisperse, spherical SiO2 monomers with volume filling factors of 0.15 ± 0.01 and 0.45 ± 0.05, respectively. The fragile projectiles were accelerated by a solenoid magnet and combined with a projectile magazine with which 25 impacts onto the same spot on the target could be performed in vacuum. We measured the mass-accretion efficiency and the volume filling factor for different impact velocities between 1.5 and 6.0 m s^{-1}. The experiments at the lowest impact speeds were performed in the Bremen drop tower under microgravity conditions to allow partial mass transfer also for the lowest adhesion case. Within this velocity range, we found a linear increase of the accretion efficiency with increasing velocity. In the laboratory experiments, the accretion efficiency increases from 0.12 to 0.21 in units of the projectile mass. The recorded images of the impacts showed that the mass transfer from the projectile to the target leads to the growth of a conical structure on the target after less than 100 impacts. From the images, we also measured the volume filling factors of the grown structures, which ranged from 0.15 (uncompacted) to 0.40 (significantly compacted) with increasing impact speed. The velocity dependency of the mass-transfer efficiency and the packing density of the resulting aggregates augment our knowledge of the aggregate growth in protoplanetary disks and should be taken into account for future models of protoplanetary dust growth.
Biologics formulation factors affecting metal leachables from stainless steel.
Zhou, Shuxia; Schöneich, Christian; Singh, Satish K
2011-03-01
An area of increasing concern and scientific scrutiny is the potential contamination of drug products by leachables entering the product during manufacturing and storage. These contaminants may either have a direct safety impact on the patients or act indirectly through the alteration of the physicochemical properties of the product. In the case of biotherapeutics, trace amounts of metal contaminants can arise from various sources, but mainly from contact with stainless steel (ss). The effect of the various factors, buffer species, solution fill volume per unit contact surface area, metal chelators, and pH, on metal leachables from contact with ss over time were investigated individually. Three major metal leachables, iron, chromium, and nickel, were monitored by inductively coupled plasma-mass spectrometry because they are the major components of 316L ss. Iron was primarily used to evaluate the effect of each factor since it is the most abundant. It was observed that each studied factor exhibited its own effect on metal leachables from contact with ss. The effect of buffer species and pH exhibited temperature dependence over the studied temperature range. The metal leachables decreased with the increased fill volume (mL) per unit contact ss surface area (cm(2)) but a plateau was achieved at approximately 3 mL/cm(2). Metal chelators produced the strongest effect in facilitating metal leaching. In order to minimize the metal leachables and optimize biological product stability, each formulation factor must be evaluated for its impact, to balance its risk and benefit in achieving the target drug product shelf life. © 2011 American Association of Pharmaceutical Scientists
Pfützner, Andreas; Schipper, Christina; Ramljak, Sanja; Flacke, Frank; Sieber, Jochen; Forst, Thomas; Musholt, Petra B
2013-11-01
Accuracy of blood glucose readings is (among other things) dependent on the test strip being completely filled with sufficient sample volume. The devices are supposed to display an error message in case of incomplete filling. This laboratory study was performed to test the performance of 31 commercially available devices in case of incomplete strip filling. Samples with two different glucose levels (60-90 and 300-350 mg/dl) were used to generate three different sample volumes: 0.20 µl (too low volume for any device), 0.32 µl (borderline volume), and 1.20 µl (low but supposedly sufficient volume for all devices). After a point-of-care capillary reference measurement (StatStrip, NovaBiomedical), the meter strip was filled (6x) with the respective volume, and the response of the meters (two devices) was documented (72 determinations/meter type). Correct response was defined as either an error message indicating incomplete filling or a correct reading (±20% compared with reference reading). Only five meters showed 100% correct responses [BGStar and iBGStar (both Sanofi), ACCU-CHEK Compact+ and ACCU-CHEK Mobile (both Roche Diagnostics), OneTouch Verio (LifeScan)]. The majority of the meters (17) had up to 10% incorrect reactions [predominantly incorrect readings with sufficient volume; Precision Xceed and Xtra, FreeStyle Lite, and Freedom Lite (all Abbott); GlucoCard+ and GlucoMen GM (both Menarini); Contour, Contour USB, and Breeze2 (all Bayer); OneTouch Ultra Easy, Ultra 2, and Ultra Smart (all LifeScan); Wellion Dialog and Premium (both MedTrust); FineTouch (Terumo); ACCU-CHEK Aviva (Roche); and GlucoTalk (Axis-Shield)]. Ten percent to 20% incorrect reactions were seen with OneTouch Vita (LifeScan), ACCU-CHEK Aviva Nano (Roche), OmniTest+ (BBraun), and AlphaChek+ (Berger Med). More than 20% incorrect reactions were obtained with Pura (Ypsomed), GlucoCard Meter and GlucoMen LX (both Menarini), Elite (Bayer), and MediTouch (Medisana). In summary, partial and incomplete blood filling of glucose meter strips is often associated with inaccurate reading. These findings underline the importance of appropriate patient education on this aspect of blood glucose self-monitoring. © 2013 Diabetes Technology Society.
Liu, Hao; Li, Wei; Liu, Can; Tan, Jie; Wang, Hong; Hai, Bao; Cai, Hong; Leng, Hui-Jie; Liu, Zhong-Jun; Song, Chun-Li
2016-10-27
Three-dimensional porous titanium alloys printed via electron beam melting have low stiffness similar to that of cortical bone and are promising scaffolds for orthopedic applications. However, the bio-inert nature of titanium alloy is poorly compatible with bone ingrowth. We previously observed that simvastatin/poloxamer 407 thermosensitive hydrogel induces endogenous angiogenic/osteogenic growth factors and promotes angiogenesis and osteogenesis, but the mechanical properties of this hydrogel are poor. The purpose of this study was to construct 3D-printed porous titanium scaffolds (pTi scaffolds) filled with simvastatin/hydrogel and evaluate the effects of this composite on osseointegration, bone ingrowth and neovascularization using a tibial defect rabbit model. Four and eight weeks after implantation, the bone volume, bone mineral density, mineral apposition rate, and push-in maximum force of the pTi scaffolds filled with simvastatin/hydrogel were significantly higher than those without simvastatin (p < 0.05). Moreover, filling with simvastatin/hydrogel significantly enhanced vascularization in and around the pTi scaffolds, and a significant correlation was observed between the volume of new bone and neovascularization (p < 0.01). In conclusion, incorporating simvastatin/poloxamer 407 hydrogel into pTi scaffolds significantly improves neovascularization, osseointegration and bone ingrowth.
Hole filling with oriented sticks in ultrasound volume reconstruction
Vaughan, Thomas; Lasso, Andras; Ungi, Tamas; Fichtinger, Gabor
2015-01-01
Abstract. Volumes reconstructed from tracked planar ultrasound images often contain regions where no information was recorded. Existing interpolation methods introduce image artifacts and tend to be slow in filling large missing regions. Our goal was to develop a computationally efficient method that fills missing regions while adequately preserving image features. We use directional sticks to interpolate between pairs of known opposing voxels in nearby images. We tested our method on 30 volumetric ultrasound scans acquired from human subjects, and compared its performance to that of other published hole-filling methods. Reconstruction accuracy, fidelity, and time were improved compared with other methods. PMID:26839907
7 CFR 920.303 - Container marking regulations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... of kiwifruit packed within the container: (1) The quantity shall be indicated in terms of count and... shall conform to the count. (2) The quantity shall be indicated in terms of the size designation and either the net weight for volume-fill containers packed by weight or the count for volume-fill containers...
30 CFR 250.614 - Well-control fluids, equipment, and operations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... workover string, the annulus shall be filled with well-control fluid before the change in such fluid level... equivalent well-control fluid volume shall be calculated and posted near the operator's station. A mechanical... utilized: (1) A fill-up line above the uppermost BOP; (2) A well-control, fluid-volume measuring device for...
Influence of the internal anatomy on the leakage of root canals filled with thermoplastic technique.
Al-Jadaa, Anas; Attin, T; Peltomäki, T; Heumann, C; Schmidlin, P R; Paquè, F
2018-04-01
The aim of this paper is to evaluate the influence of the internal anatomy on the leakage of root canals filled with the thermoplastic technique. The upper central incisors (UCI) and mesial roots of the lower molars (MRLM) (n = 12 each) were tested regarding leakage using the gas-enhanced permeation test (GEPT) after root filling. The quality of the root fillings was assessed using micro-computed tomography (μCT) by superimposing scans before and after treatment to calculate unfilled volume. The calculated void volume was compared between the groups and correlated to the measured leakage values. Data were analyzed using t test and Pearson's correlation tests (p < 0.05). The mean void volume did not differ between UCI and MRLM (13.7 ± 6.2% vs. 14.2 ± 6.8%, respectively). However, significantly more leakage was evident in the MRLM (p < 0.001). While the leakage correlated highly to the void volume in the MRLM group (R 2 = 0.981, p < 0.001), no correlation was found in UCI (R 2 = 0.467, p = 0.126). MRLM showed higher leakage values, which correlated to the void volume in the root canal fillings. Care should always be taken while doing root canal treatments, but attention to teeth with known/expected complex root canal anatomy should be considered.
Wear model simulating clinical abrasion on composite filling materials.
Johnsen, Gaute Floer; Taxt-Lamolle, Sébastien F; Haugen, Håvard J
2011-01-01
The aim of this study was to establish a wear model for testing composite filling materials with abrasion properties closer to a clinical situation. In addition, the model was used to evaluate the effect of filler volume and particle size on surface roughness and wear resistance. Each incisor tooth was prepared with nine identical standardized cavities with respect to depth, diameter, and angle. Generic composite of 3 different filler volumes and 3 different particle sizes held together with the same resin were randomly filled in respective cavities. A multidirectional wet-grinder with molar cusps as antagonist wore the surface of the incisors containing the composite fillings in a bath of human saliva at a constant temperature of 37°C. The present study suggests that the most wear resistant filling materials should consist of medium filling content (75%) and that particles size is not as critical as earlier reported.
Effects of increasing left ventricular filling pressure in patients with acute myocardial infarction
Russell, Richard O.; Rackley, Charles E.; Pombo, Jaoquin; Hunt, David; Potanin, Constantine; Dodge, Harold T.
1970-01-01
Left ventricular performance in 19 patients with acute myocardial infarction has been evaluated by measuring left ventricular response in terms of cardiac output, stroke volume, work, and power to progressive elevation of filling pressure accomplished by progressive expansion of blood volume with rapid infusion of low molecular weight dextran. Such infusion can elevate the cardiac output, stroke volume, work, and power and thus delineate the function of the left ventricle by Frank-Starling function curves. Left ventricular filling pressure in the range of 20-24 mm Hg was associated with the peak of the curves and when the filling pressure exceeded this range, the curves became flattened or decreased. An increase in cardiac output could be maintained for 4 or more hr. Patients with a flattened function curve had a high mortality in the ensuing 8 wk. The function curve showed improvement in myocardial function during the early convalescence. When left ventricular filling pressure is monitored directly or as pulmonary artery end-diastolic pressure, low molecular weight dextran provides a method for assessment of left ventricular function. Images PMID:5431663
Ladouceur, Magalie; Kachenoura, Nadjia; Soulat, Gilles; Bollache, Emilie; Redheuil, Alban; Azizi, Michel; Delclaux, Christophe; Chatellier, Gilles; Boutouyrie, Pierre; Iserin, Laurence; Bonnet, Damien; Mousseaux, Elie
2017-07-01
We aimed (1) determine if systemic right ventricle filling parameters influence systemic right ventricle stroke volume in adult patients with D-transposition of the great arteries (D-TGA) palliated by atrial switch, using cardiac magnetic resonance imaging and echocardiography, and (2) to study relationship of these diastolic parameters with exercise performance and BNP, in patients with preserved systolic systemic right ventricle function. Single-center, cross-sectional, prospective study. In patients with D-TGA palliated by atrial switch, diastolic dysfunction of the systemic right ventricle may precede systolic dysfunction. Forty-five patients with D-TGA and atrial switch and 45 age and sex-matched healthy subjects underwent cardiac magnetic resonance imaging and echocardiography. Filling flow-rates measured by phase-contrast cardiac magnetic resonance imaging were analyzed using customized software to estimate diastolic parameters and compared with exercise performance. In D-TGA, early filling of systemic right ventricle was impaired with a lower peak filling rate normalized by filling volume (Ef/FV measured by cardiac magnetic resonance imaging) and a higher early filling peak velocity normalized by early peak myocardial velocity (E US /Ea measured by echocardiography) compared with controls (P ≤ .04). Stroke volume of systemic right ventricle showed a direct and significant association with pulmonary venous pathway size (respectively r = 0.50, P < .01). Systemic right atrial area and systemic right ventricle mass/volume index measured by cardiac magnetic resonance imaging, as well as Ef/FV were significantly correlated with exercise performances and BNP (P < .01). All correlations were independent of age, gender, body mass index and blood pressure. Systemic right ventricle pre-load and stroke volume depend mainly on intraatrial pathway function. Moreover, systemic right ventricle remodeling and right atrial dysfunction impair systemic right ventricle filling, leading to BNP increase and exercise limitation. Cardiac magnetic resonance imaging should assess systemic right ventricle filling abnormalities in D-TGA patients. © 2017 Wiley Periodicals, Inc.
Kumar, Nitin; Bazerbachi, Fateh; Rustagi, Tarun; McCarty, Thomas R; Thompson, Christopher C; Galvao Neto, Manoel P; Zundel, Natan; Wilson, Erik B; Gostout, Christopher J; Abu Dayyeh, Barham K
2017-09-01
The Orbera intragastric balloon (IGB) has been approved by the US Food and Drug Administration for use in patients with a body mass index (BMI) between 30 and 40 kg/m 2 and is in wide use worldwide as a primary and bridge obesity management tool. The balloon filling volume (BFV) ranges between 400 and 700 mL of saline. Our objective was to determine whether there is an association between BFV and clinically relevant endpoints, namely weight loss outcomes, balloon tolerability, and adverse events. A systematic review of studies investigating the use of the Orbera IGB system for obesity treatment was performed. Data was examined using random effects modelling and meta-regression analyses. Forty-four studies (n = 5549 patients) reported BFV and % total body weight loss (TBWL) at 6 months. Pooled %TBWL at 6 months was 13.2% [95% CI 12.3-14.0]. A funnel plot demonstrated a low risk of publication bias. Meta-regression showed no statistically significant association between filling volume and %TBWL at 6 months (p = 0.268). Higher BFV was associated with lower rates of esophagitis (slope = -0.008, p < 0.001) and prosthesis migration (slope = -0.015, p < 0.001). There was no association between BFV and early removal (p = 0.1), gastroesophageal reflux symptom (p = 0.64), or ulcer rates (p = 0.09). No association was observed between Orbera IGB filling volume and weight loss outcomes. Higher volumes appear to be associated with lower migration and esophagitis rates; thus, a balloon filling volume of 600-650 mL is recommended.
30 CFR 250.1623 - Well-control fluids, equipment, and operations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... measuring device for determining fluid volumes when filling the hole on trips, and (3) A recording mud-pit... and an audible warning device. (c) When coming out of the hole with drill pipe or a workover string... that may be pulled prior to filling the hole and the equivalent well-control fluid volume shall be...
30 CFR 250.1623 - Well-control fluids, equipment, and operations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... measuring device for determining fluid volumes when filling the hole on trips, and (3) A recording mud-pit... and an audible warning device. (c) When coming out of the hole with drill pipe or a workover string... that may be pulled prior to filling the hole and the equivalent well-control fluid volume shall be...
30 CFR 250.1623 - Well-control fluids, equipment, and operations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... measuring device for determining fluid volumes when filling the hole on trips, and (3) A recording mud-pit... and an audible warning device. (c) When coming out of the hole with drill pipe or a workover string... that may be pulled prior to filling the hole and the equivalent well-control fluid volume shall be...
Effects of heart rate on experimentally produced mitral regurgitation in dogs.
Yoran, C; Yellin, E L; Hori, M; Tsujioka, K; Laniado, S; Sonnenblick, E H; Frater, R W
1983-12-01
The effects of increasing heart rate (HR) on the hemodynamics of acute mitral regurgitation (MR) were studied in 8 open-chest dogs. Filling volume, regurgitant volume and stroke volume were calculated from electromagnetic probe measurements of mitral and aortic flows. The left atrial-left ventricular systolic pressure gradient was measured with micromanometers. The calculated effective mitral regurgitant orifice area varied from 10 to 128 mm2, with a consequent regurgitant fraction (regurgitant volume/filling volume) of 24 to 62%. After crushing the sinus node, HR was increased stepwise from 90 to 180 beats/min by atrial pacing while maintaining aortic pressure constant. With increasing HR, filling volume, stroke volume, regurgitant volume and regurgitant time decreased; total cardiac output, forward cardiac output, regurgitant output, systolic pressure gradient, regurgitant fraction and the regurgitant orifice did not change; left ventricular end-diastolic pressure decreased; and left atrial v-wave amplitude increased. These results indicate that in acute experimental MR with a wide spectrum of incompetence, the relative distribution of forward and regurgitant flows did not change with large increases in HR. At rates greater than 150 beats/min the atrial contraction occurs early and increases the amplitude of the left atrial v wave. This may contribute to the severity of pulmonary congestion in patients with MR.
Mathematical modelling of anisotropy of illite-rich shale
Chesnokov, E.M.; Tiwary, D.K.; Bayuk, I.O.; Sparkman, M.A.; Brown, R.L.
2009-01-01
The estimation of illite-rich shale anisotropy to account for the alignment of clays and gas- or brine-filled cracks is presented via mathematical modelling. Such estimation requires analysis to interpret the dominance of one effect over another. This knowledge can help to evaluate the permeability in the unconventional reservoir, stress orientation, and the seal capacity for the conventional reservoir. Effective media modelling is used to predict the elastic properties of the illite-rich shale and to identify the dominant contributions to the shale anisotropy. We consider two principal reasons of the shale anisotropy: orientation of clay platelets and orientation of fluid-filled cracks. In reality, both of these two factors affect the shale anisotropy. The goal of this study is, first, to separately analyse the effect of these two factors to reveal the specific features in P- and S-wave velocity behaviour typical of each of the factors, and, then, consider a combined effect of the factors when the cracks are horizontally or vertically aligned. To do this, we construct four models of shale. The behaviour of P- and S-wave velocities is analysed when gas- and water-filled cracks embedded in a host matrix are randomly oriented, or horizontally or vertically aligned. The host matrix can be either isotropic or anisotropic (of VTI symmetry). In such a modelling, we use published data on mineralogy and clay platelet alignment along with other micromechanical measurements. In the model, where the host matrix is isotropic, the presence of a singularity point (when the difference VS1 - VS2 changes its sign) in shear wave velocities is an indicator of brine-filled aligned cracks. In the model with the VTI host matrix and horizontally aligned cracks filled with gas, an increase in their volume concentration leads to that the azimuth at which the singularity is observed moves toward the symmetry axis. In this case, if the clay content is small (around 20 per cent), the singularity point may even vanish. The Thomsen parameters are helpful in fluid type indication in shale. An indicator of gas-filled aligned cracks is ?? > ??. If aligned cracks in illite-rich shale are brine-filled, ?? < ??. Negative value of ?? indicates brine-filled cracks in illite-rich shale. A shale with brine-filled cracks exhibits higher Vp/Vs ratio in the vertical direction as compared to the gas-filled shale. A disorientation of clay platelets and brine-filled cracks may lead to that the singularity point is absent for brine-saturated shale as well. In this case one can also observe ?? > ?? and decreased values of Vp/Vs in the vertical direction as in the case of gas-filled cracks. In the presence of vertically aligned cracks, shales exhibit distinctly revealed features of orthorhombic symmetry. The results have important applications where seismic measurements are applied to predict the maturity state of the shale. ?? 2009 The Authors Journal compilation ?? 2009 RAS.
Micro-CT and nano-CT analysis of filling quality of three different endodontic sealers.
Huang, Yan; Celikten, Berkan; de Faria Vasconcelos, Karla; Ferreira Pinheiro Nicolielo, Laura; Lippiatt, Nicholas; Buyuksungur, Arda; Jacobs, Reinhilde; Orhan, Kaan
2017-12-01
To investigate voids in different root canal sealers using micro-CT and nano-CT, and to explore the feasibility of using nano-CT for quantitative analysis of sealer filling quality. 30 extracted mandibular central incisors were randomly assigned into three groups according to the applied root canal sealers (Total BC Sealer, Sure Seal Root, AH Plus) by the single cone technique. Subsequently, micro-CT and nano-CT were performed to analyse the incidence rate of voids, void fraction, void volume and their distribution in each sample. Micro-CT evaluation showed no significant difference among sealers for the incidence rate of voids or void fraction in the whole filling materials (p > 0.05), whereas a significant difference was found between AH Plus and the other two sealers using nano-CT (p < 0.05). All three sealers presented less void volume in the apical third; however, higher void volumes were observed in the apical and coronal thirds in AH Plus using micro-CT (p < 0.05), while nano-CT results displayed higher void volume in AH Plus among all the sealers and regions (p < 0.05). Bioactive sealers showed higher root filling rate, lower incidence rate of voids, void fraction and void volume than AH Plus under nano-CT analysis, when round root canals were treated by the single cone technique. The disparate results suggest that the higher resolution of nano-CT have a greater ability of distinguishing internal porosity, and therefore suggesting the potential use of nano-CT in quantitative analysis of filling quality of sealers.
Barreto, Mirela Sangoi; da Rosa, Ricardo Abreu; Santini, Manuela Favarin; Cavenago, Bruno Cavalini; Duarte, Marco Antônio Húngaro; Bier, Carlos Alexandre Souza; Só, Marcos Vinícius Reis
2016-01-01
ABSTRACT Objectives The aim of this study was to evaluate the volume of remaining filling material after passive ultrasonic irrigation (PUI) of sodium hypochlorite (NaOCl) and orange oil in mesial canals of mandibular molars, with and without isthmus. Material and Methods Thirty mesial roots of mandibular molars were divided according to the presence or absence of isthmus. Canals were prepared and filled (Micro-CT #1). Filling was removed using rotary instruments, and specimens were sub-divided into three groups according to the irrigation procedures: Conventional – conventional irrigation with NaOCl, PUI/NaOCl – PUI of NaOCl (three activations, 20 seconds each), and PUI/orange oil – PUI of orange oil (Micro-CT#2). Specimens were enlarged using the X2 and X3 ProTaper Next instruments and submitted to the same irrigation protocols (Micro-CT #3). Results No differences were found between the experimental groups in each stage of assessment (P>0.05). The volume of residual filling material was similar to those in Micro-CT #2 and Micro-CT #3, but lower than those observed in Micro-CT #1 (P<0.05). When groups were pooled according to the presence or absence of an isthmus, volume of residual filling material was higher in specimens presenting isthmus (P<0.05). Conclusions PUI of NaOCl or orange oil did not improve filling removal. Isthmus consists in an anatomical obstacle that impairs the removal of filling material. PMID:26200525
Large-scale tomographic particle image velocimetry using helium-filled soap bubbles
NASA Astrophysics Data System (ADS)
Kühn, Matthias; Ehrenfried, Klaus; Bosbach, Johannes; Wagner, Claus
2011-04-01
To measure large-scale flow structures in air, a tomographic particle image velocimetry (tomographic PIV) system for measurement volumes of the order of one cubic metre is developed, which employs helium-filled soap bubbles (HFSBs) as tracer particles. The technique has several specific characteristics compared to most conventional tomographic PIV systems, which are usually applied to small measurement volumes. One of them is spot lights on the HFSB tracers, which slightly change their position, when the direction of observation is altered. Further issues are the large particle to voxel ratio and the short focal length of the used camera lenses, which result in a noticeable variation of the magnification factor in volume depth direction. Taking the specific characteristics of the HFSBs into account, the feasibility of our large-scale tomographic PIV system is demonstrated by showing that the calibration errors can be reduced down to 0.1 pixels as required. Further, an accurate and fast implementation of the multiplicative algebraic reconstruction technique, which calculates the weighting coefficients when needed instead of storing them, is discussed. The tomographic PIV system is applied to measure forced convection in a convection cell at a Reynolds number of 530 based on the inlet channel height and the mean inlet velocity. The size of the measurement volume and the interrogation volumes amount to 750 mm × 450 mm × 165 mm and 48 mm × 48 mm × 24 mm, respectively. Validation of the tomographic PIV technique employing HFSBs is further provided by comparing profiles of the mean velocity and of the root mean square velocity fluctuations to respective planar PIV data.
Remotely detected high-field MRI of porous samples
NASA Astrophysics Data System (ADS)
Seeley, Juliette A.; Han, Song-I.; Pines, Alexander
2004-04-01
Remote detection of NMR is a novel technique in which an NMR-active sensor surveys an environment of interest and retains memory of that environment to be recovered at a later time in a different location. The NMR or MRI information about the sensor nucleus is encoded and stored as spin polarization at the first location and subsequently moved to a different physical location for optimized detection. A dedicated probe incorporating two separate radio frequency (RF)—circuits was built for this purpose. The encoding solenoid coil was large enough to fit around the bulky sample matrix, while the smaller detection solenoid coil had not only a higher quality factor, but also an enhanced filling factor since the coil volume comprised purely the sensor nuclei. We obtained two-dimensional (2D) void space images of two model porous samples with resolution less than 1.4 mm 2. The remotely reconstructed images demonstrate the ability to determine fine structure with image quality superior to their directly detected counterparts and show the great potential of NMR remote detection for imaging applications that suffer from low sensitivity due to low concentrations and filling factor.
Crystallization of sheared hard spheres at 64.5% volume fraction
NASA Astrophysics Data System (ADS)
Swinney, H. L.; Rietz, F.; Schroeter, M.; Radin, C.
2017-11-01
A classic experiment by G.D. Scott Nature 188, 908, 1960) showed that pouring balls into a rigid container filled the volume to an upper limit of 64% of the container volume, which is well below the 74% volume fraction filled by spheres in a hexagonal close packed (HCP) or face center cubic (FCC) lattice. Subsequent experiments have confirmed a ``random closed packed'' (RCP) fraction of about 64%. However, the physics of the RCP limit has remained a mystery. Our experiment on a cubical box filled with 49400 weakly sheared glass spheres reveals a first order phase transition from a disordered to an ordered state at a volume fraction of 64.5%. The ordered state consists of crystallites of mixed FCC and HCP symmetry that coexist with the amorphous bulk. The transition is initiated by homogeneous nucleation: in the shearing process small crystallites with about ten or fewer spheres dissolve, while larger crystallites grow. A movie illustrates the crystallization process. German Academic Exchange Service (DAAD), German Research Foundation (DFG), NSF DMS, and R.A. Welch Foundation.
Gas permeability measurements for film envelope materials
Ludtka, G.M.; Kollie, T.G.; Watkin, D.C.; Walton, D.G.
1998-05-12
Method and apparatus for measuring the permeability of polymer film materials such as used in super-insulation powder-filled evacuated panels (PEPs) reduce the time required for testing from several years to weeks or months. The method involves substitution of a solid non-outgassing body having a free volume of between 0% and 25% of its total volume for the usual powder in the PEP to control the free volume of the ``body-filled panel.`` Pressure versus time data for the test piece permit extrapolation to obtain long term performance of the candidate materials. 4 figs.
Gas permeability measurements for film envelope materials
Ludtka, Gerard M.; Kollie, Thomas G.; Watkin, David C.; Walton, David G.
1998-01-01
Method and apparatus for measuring the permeability of polymer film materials such as used in super-insulation powder-filled evacuated panels (PEPs) reduce the time required for testing from several years to weeks or months. The method involves substitution of a solid non-outgassing body having a free volume of between 0% and 25% of its total volume for the usual powder in the PEP to control the free volume of the "body-filled panel". Pressure versus time data for the test piece permit extrapolation to obtain long term performance of the candidate materials.
Investigating the Stability of a Bottle Filled with Different Amounts of Fluid
ERIC Educational Resources Information Center
Pahwa, Gantavya; Pingali, Rushil G.; Khubchandani, Aashish K.; Roy, Ekansh; Mudaliyar, Roshni R.; Mudaliyar, Rajesh P.
2017-01-01
The aim of this paper is to investigate the stability of a bottle filled with different volumes of water, and to determine the angle at which it topples over for each volume of water. Data for the angle at which the bottle toppled were gathered experimentally using a cylindrical 1 litre bottle, and two theoretical models were then developed,…
Mid-infrared interferometry of Seyfert galaxies: Challenging the Standard Model
NASA Astrophysics Data System (ADS)
López-Gonzaga, N.; Jaffe, W.
2016-06-01
Aims: We aim to find torus models that explain the observed high-resolution mid-infrared (MIR) measurements of active galactic nuclei (AGN). Our goal is to determine the general properties of the circumnuclear dusty environments. Methods: We used the MIR interferometric data of a sample of AGNs provided by the instrument MIDI/VLTI and followed a statistical approach to compare the observed distribution of the interferometric measurements with the distributions computed from clumpy torus models. We mainly tested whether the diversity of Seyfert galaxies can be described using the Standard Model idea, where differences are solely due to a line-of-sight (LOS) effect. In addition to the LOS effects, we performed different realizations of the same model to include possible variations that are caused by the stochastic nature of the dusty models. Results: We find that our entire sample of AGNs, which contains both Seyfert types, cannot be explained merely by an inclination effect and by including random variations of the clouds. Instead, we find that each subset of Seyfert type can be explained by different models, where the filling factor at the inner radius seems to be the largest difference. For the type 1 objects we find that about two thirds of our objects could also be described using a dusty torus similar to the type 2 objects. For the remaining third, it was not possible to find a good description using models with high filling factors, while we found good fits with models with low filling factors. Conclusions: Within our model assumptions, we did not find one single set of model parameters that could simultaneously explain the MIR data of all 21 AGN with LOS effects and random variations alone. We conclude that at least two distinct cloud configurations are required to model the differences in Seyfert galaxies, with volume-filling factors differing by a factor of about 5-10. A continuous transition between the two types cannot be excluded.
Hammad, Mohammad; Qualtrough, Alison; Silikas, Nick
2008-11-01
The aim of this study was to measure the remaining filling volume of different obturation materials from root-filled extracted teeth by using 2 removal techniques. Eighty single-rooted teeth were collected and decoronated, and the root canal was prepared by using the ProTaper nickel-titanium rotary files. The teeth were randomly allocated into 4 groups, and each group was obturated by using a different material. Group 1 was filled with gutta-percha and TubliSeal sealer, group 2 was filled with EndoRez points and EndoRez sealer, group 3 was filled with RealSeal points and RealSeal sealer, and Group 4 was filled with a gutta-percha point and GuttaFlow sealer. Teeth were scanned with a micro-computed tomography scan, and then root fillings were removed by using ProTaper retreatment files or hand K-files. Teeth were scanned again, and volume measurements were carried out with micro-computed tomography software. Statistical analysis showed significant differences between the 2 removal techniques for gutta-percha and for both techniques between gutta-percha and the other groups. The present study showed that all tested filling materials were not completely removed during retreatment by using hand or rotary files. Gutta-percha was more efficiently removed by using hand K-files.
DeAngelis, Anthony; Kuchel, George A.
2012-01-01
The prevalence of urinary symptoms increases with age and is a significant source of distress, morbidity, and expense in the elderly. Recent evidence suggests that symptoms in the aged may result from sensory dysfunction, rather than abnormalities of detrusor performance. Therefore, we employed a pressure/flow multichannel urethane-anesthetized mouse cystometry model to test the hypothesis that in vivo detrusor performance does not degrade with aging. Secondarily, we sought to evaluate sensory responsiveness to volume using pressure-volume data generated during bladder filling. Cystometric data from 2-, 12-, 22-, and 26-mo-old female C57BL6 mice were compared. All 2- and 12-mo-old mice, 66% of 22-mo-old mice, and 50% of 26-mo-old mice responded to continuous bladder filling with periodic reflex voiding. Abdominal wall contraction with voiding had a minimal contribution to expulsive pressure, whereas compliance pressure was a significant contributor. Maximum bladder pressure, estimated detrusor pressure, detrusor impulse (pressure-time integral), as well as indices of detrusor power and work, did not decrease with aging. Bladder precontraction pressures decreased, compliance increased, and nonvoiding contraction counts did not change with increasing age. Intervoid intervals, per-void volumes, and voiding flow rates increased with age. Calculations approximating wall stress during filling suggested loss of bladder volume sensitivity with increasing age. We conclude that aging is associated with an impaired ability to respond to the challenge of continuous bladder filling with cyclic voiding, yet among responsive animals, voiding detrusor contraction strength does not degrade with aging in this murine model. Furthermore, indirect measures suggest that bladder volume sensitivity is diminished. Thus, changes in homeostatic reserve and peripheral and/or central sensory mechanisms may be important contributors to aging-associated changes in bladder function. PMID:22204955
Ilic, Ivan; Stankovic, Ivan; Vidakovic, Radosav; Jovanovic, Vladimir; Vlahovic Stipac, Alja; Putnikovic, BiIjana; Neskovic, Aleksandar N
2015-04-01
Little is known about the impact of duration of ischemia on left atrial (LA) volumes and function during acute phase of myocardial infarction. We investigated the relationship of ischemic times, echocardiographic indices of diastolic function and LA volumes in patients with ST-segment elevation myocardial infarction (STEMI) treated with primary percutaneous coronary intervention (PCI). A total of 433 consecutive STEMI patients underwent echocardiographic examination within 48 h of primary PCI, including the measurement of LA volumes and the ratio of mitral peak velocity of early filling to early diastolic mitral annular velocity (E/e'). Time intervals from onset of chest pain to hospital admission and reperfusion were collected and magnitude of Troponin I release was used to assess infarct size. Patients with LA volume index (LAVI) ≥28 ml/m(2) had longer total ischemic time (410 ± 347 vs. 303 ± 314 min, p = 0.007) and higher E/e' ratio (15 ± 5 vs. 10 ± 3, p < 0.001) than those with LAVI <28 ml/m(2), while the indices of LA function were similar between the study groups (p > 0.05, for all). Significant correlation was found between E/e' and LA volumes at all stages of LA filling and contraction (r = 0.363-0.434; p < 0.001, for all) while total ischemic time along with E/e' and restrictive filling pattern remained independent predictor of LA enlargement. Increased LA volume is associated with longer ischemic times and may be a sensitive marker of increased left ventricular filling pressures in STEMI patients treated with primary PCI.
Symposium on Engineering With Nuclear Explosives January 14-16, 1970 Las Vegas, Nevada. Volume 2
1970-05-01
stainless steel funnel over an enamel tub. Every attempt was made to slowly wet all the surfaces with no jetting, hydraulic washing, or mechanical...If the signals of shovel tooth wear and bucket filling factors indicate this, then drilling for high-explosive blasting will commence. Benches are...furnace. The whole range of states between undamaged granite and glass is indeed found : 1 - granite may be only whitened . The iron oxydes naturally
Bouncing behavior of microscopic dust aggregates
NASA Astrophysics Data System (ADS)
Seizinger, A.; Kley, W.
2013-03-01
Context. Bouncing collisions of dust aggregates within the protoplanetary disk may have a significant impact on the growth process of planetesimals. Yet, the conditions that result in bouncing are not very well understood. Existing simulations studying the bouncing behavior used aggregates with an artificial, very regular internal structure. Aims: Here, we study the bouncing behavior of sub-mm dust aggregates that are constructed applying different sample preparation methods. We analyze how the internal structure of the aggregate alters the collisional outcome and we determine the influence of aggregate size, porosity, collision velocity, and impact parameter. Methods: We use molecular dynamics simulations where the individual aggregates are treated as spheres that are made up of several hundred thousand individual monomers. The simulations are run on graphic cards (GPUs). Results: Statistical bulk properties and thus bouncing behavior of sub-mm dust aggregates depend heavily on the preparation method. In particular, there is no unique relation between the average volume filling factor and the coordination number of the aggregate. Realistic aggregates bounce only if their volume filling factor exceeds 0.5 and collision velocities are below 0.1 ms-1. Conclusions: For dust particles in the protoplanetary nebula we suggest that the bouncing barrier may not be such a strong handicap in the growth phase of dust agglomerates, at least in the size range of ≈100 μm.
An Ultra-fast X-Ray Disk Wind in the Neutron Star Binary GX 340+0
NASA Astrophysics Data System (ADS)
Miller, J. M.; Raymond, J.; Cackett, E.; Grinberg, V.; Nowak, M.
2016-05-01
We present a spectral analysis of a brief Chandra/HETG observation of the neutron star low-mass X-ray binary GX 340+0. The high-resolution spectrum reveals evidence of ionized absorption in the Fe K band. The strongest feature, an absorption line at approximately 6.9 keV, is required at the 5σ level of confidence via an F-test. Photoionization modeling with XSTAR grids suggests that the line is the most prominent part of a disk wind with an apparent outflow speed of v = 0.04c. This interpretation is preferred at the 4σ level over a scenario in which the line is H-like Fe xxvi at a modest redshift. The wind may achieve this speed owing to its relatively low ionization, enabling driving by radiation pressure on lines; in this sense, the wind in GX 340+0 may be the stellar-mass equivalent of the flows in broad absorption line quasars. If the gas has a unity volume filling factor, the mass ouflow rate in the wind is over 10-5 M ⊙ yr-1, and the kinetic power is nearly 1039 erg s-1 (or, 5-6 times the radiative Eddington limit for a neutron star). However, geometrical considerations—including a small volume filling factor and low covering factor—likely greatly reduce these values.
Falabella, Steven; Meyer, Glenn A; Tang, Vincent; Guethlein, Gary
2014-06-10
A two-phase mixed media insulator having a dielectric fluid filling the interstices between macro-sized dielectric beads packed into a confined volume, so that the packed dielectric beads inhibit electro-hydrodynamically driven current flows of the dielectric liquid and thereby increase the resistivity and breakdown strength of the two-phase insulator over the dielectric liquid alone. In addition, an electrical apparatus incorporates the two-phase mixed media insulator to insulate between electrical components of different electrical potentials. And a method of electrically insulating between electrical components of different electrical potentials fills a confined volume between the electrical components with the two-phase dielectric composite, so that the macro dielectric beads are packed in the confined volume and interstices formed between the macro dielectric beads are filled with the dielectric liquid.
Coorevits, L; Van den Abeele, A-M
2015-07-01
The yield of blood cultures is proportional to the volume of blood cultured. We evaluated an automatic blood volume monitoring system, recently developed by Becton Dickinson within its BACTEC EpiCenter module, that calculates mean volumes of negative aerobic bottles and generates boxplots and histograms. First, we evaluated the filling degree of 339 aerobic glass blood cultures by calculating the weight-based volume for each bottle. A substantial amount of the bottles (48.3%) were inadequately filled. Evaluation of the accuracy of the monitoring system showed a mean bias of -1.4 mL (-15.4%). Additional evaluation, using the amended software on 287 aerobic blood culture bottles, resulted in an acceptable mean deviation of -0.3 mL (-3.3%). The new software version was also tested on 200 of the recently introduced plastic bottles, which will replace the glass bottles in the near future, showing a mean deviation of +2.8 mL (+26.7%). In conclusion, the mean calculated volumes can be used for the training of a single phlebotomist. However, filling problems appear to be masked when using them for phlebotomist groups or on wards. Here, visual interpretation of boxplots and histograms can serve as a useful tool to observe the spread of the filling degrees and to develop a continuous improvement program. Re-adjustment of the software has proven to be necessary for use with plastic bottles. Due to our findings, BD has developed further adjustments to the software for validated use with plastic bottles, which will be released soon.
The role of elastic restoring forces in right-ventricular filling
Pérez Del Villar, Candelas; Bermejo, Javier; Rodríguez-Pérez, Daniel; Martínez-Legazpi, Pablo; Benito, Yolanda; Antoranz, J. Carlos; Desco, M. Mar; Ortuño, Juan E.; Barrio, Alicia; Mombiela, Teresa; Yotti, Raquel; Ledesma-Carbayo, Maria J.; Del Álamo, Juan C.; Fernández-Avilés, Francisco
2015-01-01
Aims The physiological determinants of RV diastolic function remain poorly understood. We aimed to quantify the contribution of elastic recoil to RV filling and determine its sensitivity to interventricular interaction. Methods and results High-fidelity pressure–volume loops and simultaneous 3-dimensional ultrasound sequences were obtained in 13 pigs undergoing inotropic modulation, volume overload, and acute pressure overload induced by endotoxin infusion. Using a validated method, we isolated elastic restoring forces from ongoing relaxation using conventional pressure–volume data. The RV contracted below the equilibrium volume in >75% of the data sets. Consequently, elastic recoil generated strong sub-atmospheric passive pressure at the onset of diastole [−3 (−4 to −2) mmHg at baseline]. Stronger restoring suction pressure was related to a shorter isovolumic relaxation period, a higher rapid filling fraction, and lower atrial pressures (all P < 0.05). Restoring forces were mostly determined by the position of operating volumes around the equilibrium volume. By this mechanism, the negative inotropic effect of beta-blockade reduced and sometimes abolished restoring forces. During acute pressure overload, restoring forces initially decreased, but recovered at advanced stages. This biphasic response was related to alterations of septal curvature induced by changes in the diastolic LV–RV pressure balance. The constant of elastic recoil was closely related to the constant of passive stiffness (R = 0.69). Conclusion The RV works as a suction pump, exploiting contraction energy to facilitate filling by means of strong elastic recoil. Restoring forces are influenced by the inotropic state and RV conformational changes mediated by direct ventricular interdependence. PMID:25691537
Fan, Haitao T; Zhang, Renjie J; Shen, Cailiang L; Dong, Fulong L; Li, Yong; Song, Peiwen W; Gong, Chen; Wang, Yijin J
2016-03-01
The biomechanics of pedicle screw fixation combined with trajectory cement augmentation with various filling volumes were measured by pull-out, periodic antibending, and compression fatigue tests. To investigate the biomechanical properties of the pedicle screw fixation combined with trajectory bone cement (polymethylmethacrylate) augmentation in osteoporotic vertebrae and to explore the optimum filling volume of the bone cement. Pedicle screw fixation is considered to be the most effective posterior fixation method. The decrease of the bone mineral density apparently increases the fixation failure risk caused by screw loosening and displacement. Trajectory bone cement augmentation has been confirmed to be an effective method to increase the bone intensity and could markedly increase the stability of the fixation interface. Sixteen elderly cadaveric 1-5 lumbar vertebral specimens were diagnosed with osteoporosis. The left and right vertebral pedicles were alternatively randomized for treatment in all groups, with the contralateral pedicles as control. The study groups included: group A (pedicle screw fixation with full trajectory bone cement augmentation), group B (75% filling), group C (50% filling), and group D (25% filling). Finally, the bone cement leakage and dispersion were assessed and the mechanical testing was conducted. The bone cement was well dispersed around the pedicle screw. The augmented bone intensity, pull-out strength, periodic loading times, and compression fatigue performance were markedly higher than those of the control groups. With the increase in trajectory bone cement, the leakage was also increased (P<0.05). The pull-out strength of the pedicle screw was increased with an increase in bone mineral density and trajectory bone cement. It peaked at 75% filling, with the largest power consumption. The optimal filling volume of the bone cement was 75% of the trajectory volume (about 1.03 mL). The use of excessive bone cement did not increase the fixation intensity but increased the risk of leakage.
2014-01-01
Background Although increased volume of pericardial fat has been associated with decreased cardiac function, it is unclear whether this association is mediated by systemic overall obesity or direct regional fat interactions. We hypothesized that if local effects dominate, left ventricular (LV) function would be most strongly associated with pericardial fat that surrounds the left rather than the right ventricle (RV). Methods Female obese subjects (n = 60) had cardiovascular magnetic resonance (CMR) scans to obtain measures of LV function and pericardial fat volumes. LV function was obtained using the cine steady state free precession imaging in short axis orientation. The amount of pericardial fat was determined volumetrically by the cardiac gated T1 black blood imaging and normalized to body surface area. Results In this study cohort, LV fat correlated with several LV hemodynamic measurements including cardiac output (r = -0.41, p = 0.001) and stroke volume (r = -0.26, p = 0.05), as well as diastolic functional parameters including peak-early-filling rate (r = -0.38, p = 0.01), early late filling ratio (r = -0.34, p = 0.03), and time to peak-early-filling (r = 0.34, p = 0.03). These correlations remained significant even after adjusting for the body mass index and the blood pressure. However, similar correlations became weakened or even disappeared between RV fat and LV function. LV function was not correlated with systemic plasma factors, such as C-reactive protein (CRP), B-type natriuretic peptide (BNP), Interleukin-6 (IL-6), resistin and adiponectin (all p > 0.05). Conclusions LV hemodynamic and diastolic function was associated more with LV fat as compared to RV or total pericardial fat, but not with systemic inflammatory markers or adipokines. The correlations between LV function and pericardial fat remained significant even after adjusting for systemic factors. These findings suggest a site-specific influence of pericardial fat on LV function, which could imply local secretion of molecules into the underlying tissue or an anatomic effect, both mechanisms meriting future evaluation. PMID:24884541
Design of planar microcoil-based NMR probe ensuring high SNR
NASA Astrophysics Data System (ADS)
Ali, Zishan; Poenar, D. P.; Aditya, Sheel
2017-09-01
A microNMR probe for ex vivo applications may consist of at least one microcoil, which can be used as the oscillating magnetic field (MF) generator as well as receiver coil, and a sample holder, with a volume in the range of nanoliters to micro-liters, placed near the microcoil. The Signal-to-Noise ratio (SNR) of such a probe is, however, dependent not only on its design but also on the measurement setup, and the measured sample. This paper introduces a performance factor P independent of both the proton spin density in the sample and the external DC magnetic field, and which can thus assess the performance of the probe alone. First, two of the components of the P factor (inhomogeneity factor K and filling factor η ) are defined and an approach to calculate their values for different probe variants from electromagnetic simulations is devised. A criterion based on dominant component of the magnetic field is then formulated to help designers optimize the sample volume which also affects the performance of the probe, in order to obtain the best SNR for a given planar microcoil. Finally, the P factor values are compared between different planar microcoils with different number of turns and conductor aspect ratios, and planar microcoils are also compared with conventional solenoids. These comparisons highlight which microcoil geometry-sample volume combination will ensure a high SNR under any external setup.
Improving Crotalidae polyvalent immune Fab reconstitution times.
Quan, Asia N; Quan, Dan; Curry, Steven C
2010-06-01
Crotalidae polyvalent immune Fab (CroFab) is used to treat rattlesnake envenomations in the United States. Time to infusion may be a critical factor in the treatment of these bites. Per manufacturer's instructions, 10 mL of sterile water for injection (SWI) and hand swirling are recommended for reconstitution. We wondered whether completely filling vials with 25 mL of SWI would result in shorter reconstitution times than using 10-mL volumes and how hand mixing compared to mechanical agitation of vials or leaving vials undisturbed. Six sets of 5 vials were filled with either 10 mL or 25 mL. Three mixing techniques were used as follows: undisturbed; agitation with a mechanical agitator; and continuous hand rolling and inverting of vials. Dissolution was determined by observation and time to complete dissolution for each vial. Nonparametric 2-tailed P values were calculated. Filling vials completely with 25 mL resulted in quicker dissolution than using 10-mL volumes, regardless of mixing method (2-tailed P = .024). Mixing by hand was shorter than other methods (P < .001). Reconstitution with 25 mL and hand mixing resulted in the shortest dissolution times (median, 1.1 minutes; range, 0.9-1.3 minutes). This appeared clinically important because dissolution times using 10 mL and mechanical rocking of vials (median, 26.4 minutes) or leaving vials undisturbed (median, 33.6 minutes) was several-fold longer. Hand mixing after filling vials completely with 25 mL results in shorter dissolution times than using 10 mL or other methods of mixing and is recommended, especially when preparing initial doses of CroFab. Copyright (c) 2010 Elsevier Inc. All rights reserved.
Role of atrial natriuretic peptide in systemic responses to acute isotonic volume expansion
NASA Technical Reports Server (NTRS)
Watenpaugh, Donald E.; Yancy, Clyde W.; Buckey, Jay C.; Lane, Lynda D.; Hargens, Alan R.; Blomqvist, C. G.
1992-01-01
A hypothesis is proposed that a temporal relationship exists between increases in cardiac filling pressure and plasma artrial natriuretic peptide (ANP) concentration and also between ANP elevation and vasodilation, fluid movement from plasma to interstitium, and increased urine volume (UV). To test the hypothesis, 30 ml/kg isotonic saline were infused in supine male subjects over 24 min and responses were monitored for 3 h postinfusion. Results show that at end infusion, mean arterial pressure (RAP), heart rate and plasma volume exhibited peak increases of 146, 23, and 27 percent, respectively. Mean plasma ANP and UV peaked (45 and 390 percent, respectively) at 30 min postinfusion. Most cardiovascular variables had returned toward control levels by 1 h postinfusion, and net reabsorption of extravascular fluid ensued. It is concluded that since ANP was not significantly increased until 30 min postinfusion, factors other than ANP initiate responses to intravascular fluid loading. These factors include increased vascular pressures, baroreceptor-mediated vasolidation, and hemodilution of plasma proteins. ANP is suggested to mediate, in part, the renal response to saline infusion.
TU-H-206-02: Novel Linearly-Filled Derenzo PET Phantom Design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Graves, S; Cox, B; Valdovinos, H
Purpose: To design a linearly-filled Derenzo positron emission tomography (PET) phantom, eliminating the extraneous radioisotope volumes in a conventional reservoir-type design. This activity reduction combined with the elimination of bubbles in smaller phantom channels would significantly reduce personnel dose, radioisotope cost, and would improve image quality by reducing out-of-slice activity scatter. Methods: A computer-aided design (CAD) was created of a modular Derenzo phantom consisting of three phantom layers with gaskets between the layers. The central piece contains the active pattern volume and channels connecting adjacent rods in a serpentine pattern. The two end-pieces contained an inlet and an outlet formore » filling purposes. Phantom prototypes were 3D printed on a Viper Si2 stereolithography machine. The two gaskets were fabricated from silicon sheets using a PLS 6.75 laser cutter. Phantoms were held together by pass-through glass-filled nylon bolts and nuts. Phantoms were filled with {sup 52}Mn, {sup 64}Cu, {sup 74}Br, and {sup 124}I for testing, and were imaged on a Siemens Inveon MicroPET scanner. Results: Four phantom prototypes were constructed using male Leur Lock fittings for inlet/outlet ports. 3D printed layers were sanded to ensure proper coupling to the silicon gaskets. The filling volume for each prototype was approximately 2.4 mL. The filling process was found to be rapid, leak-tight, and with minimal back-pressure. PET images were reconstructed by OSEM3D, and axial slices along the phantom pattern length were averaged to provide final images. Image distortion was isotope dependent with {sup 52}Mn and {sup 64}Cu having the least distortion and {sup 124}I having the most distortion. Conclusion: These results indicate that the linearlyfilled Derenzo design improves on conventional reservoir-type designs by eliminating potential bubbles in small channels and by reducing activity level, radioisotope volume, radioisotope cost, personnel dose, filling time, and out-of-slice activity scatter The method described in this abstract has been filed as a patent application to the US Patent and Trade Office by the Wisconsin Alumni Research Foundation (WARF).« less
Diastolic viscous properties of the intact canine left ventricle.
Nikolic, S D; Tamura, K; Tamura, T; Dahm, M; Frater, R W; Yellin, E L
1990-08-01
The viscoelastic model of the ventricle predicts that the rate of change of volume (strain rate) is a determinant of the instantaneous pressure in the ventricle during diastole. Because relaxation is not complete before the onset of filling, one cannot distinguish the individual effects of relaxation and viscosity unless the passive and active components that determine the ventricular pressure are separated. To overcome this problem, we used the method of ventricular volume clamping to compare the pressures in the fully relaxed ventricle at a given volume at zero strain rate (static pressure) and high strain rate (dynamic pressure). Six open-chest, fentanyl-anesthetized dogs were instrumented with micromanometers and an electronically controlled mitral valve occluder in series with the electromagnetic flow probe. We reasoned as follows: If there were significant viscosity, then the dynamic pressure would be higher than the static pressure. The static pressure was measured when the ventricle was completely relaxed following a mitral valve occlusion after an arbitrary filling volume had been achieved. The dynamic pressure was determined by delaying the onset of filling until relaxation was complete and then measuring the pressure at the same volume that was achieved when the static pressure was measured. In 19 different hemodynamic situations, the dynamic and static pressures were identical (mean difference, 0.1 +/- 0.8 mm Hg), indicating that in the passive ventricle viscoelastic effects are insignificant and do not contribute to the left ventricular diastolic pressure under normal filling rates.
Stelljes, Tenzin Sonam; Looe, Hui Khee; Harder, Dietrich; Poppe, Björn
2017-03-01
Two-dimensional detector arrays are routinely used for constancy checks and treatment plan verification in photon-beam radiotherapy. In addition to the spatial resolution of the dose profiles, the "coverage" of the radiation field with respect to the detection of any beam collimation deficiency appears as the second characteristic feature of a detector array. The here proposed "collimator monitoring fill factor" (CM fill factor) has been conceived to serve as a quantitative characteristic of this "coverage". The CM fill factor is defined as the probability of a 2D array to detect any collimator position error. Therefore, it is represented by the ratio of the "sensitive area" of a single detector, in which collimator position errors are detectable, and the geometrical "cell area" associated with this detector within the array. Numerical values of the CM fill factor have been Monte Carlo simulated for 2D detector arrays equipped with air-vented ionization chambers, liquid-filled ionization chambers and diode detectors and were compared with the "FWHM fill factor" defined by Gago-Arias et al. (2012). For arrays with vented ionization chambers, the differences between the CM fill factor and the FWHM fill factor are moderate, but occasionally the latter exceeds unity. For narrower detectors such as liquid-filled ionization chambers and Si diodes and for small sampling distances, large differences between the FWHM fill factor and the CM fill factor have been observed. These differences can be explained by the shapes of the fluence response functions of these narrow detectors. A new parameter "collimator monitoring fill factor" (CM fill factor), applicable to quantitate the collimator position error detection probability of a 2D detector array, has been proposed. It is designed as a help in classifying the clinical performance of two-dimensional detector arrays in photon-beam radiotherapy. © 2017 American Association of Physicists in Medicine.
GPU-accelerated Kernel Regression Reconstruction for Freehand 3D Ultrasound Imaging.
Wen, Tiexiang; Li, Ling; Zhu, Qingsong; Qin, Wenjian; Gu, Jia; Yang, Feng; Xie, Yaoqin
2017-07-01
Volume reconstruction method plays an important role in improving reconstructed volumetric image quality for freehand three-dimensional (3D) ultrasound imaging. By utilizing the capability of programmable graphics processing unit (GPU), we can achieve a real-time incremental volume reconstruction at a speed of 25-50 frames per second (fps). After incremental reconstruction and visualization, hole-filling is performed on GPU to fill remaining empty voxels. However, traditional pixel nearest neighbor-based hole-filling fails to reconstruct volume with high image quality. On the contrary, the kernel regression provides an accurate volume reconstruction method for 3D ultrasound imaging but with the cost of heavy computational complexity. In this paper, a GPU-based fast kernel regression method is proposed for high-quality volume after the incremental reconstruction of freehand ultrasound. The experimental results show that improved image quality for speckle reduction and details preservation can be obtained with the parameter setting of kernel window size of [Formula: see text] and kernel bandwidth of 1.0. The computational performance of the proposed GPU-based method can be over 200 times faster than that on central processing unit (CPU), and the volume with size of 50 million voxels in our experiment can be reconstructed within 10 seconds.
Leinwand, Joshua C; Zhao, Binsheng; Guo, Xiaotao; Krishnamoorthy, Saravanan; Qi, Jing; Graziano, Joseph H; Slavkovic, Vesna N; Bates, Gleneara E; Lewin, Sharyn N; Allendorf, John D; Chabot, John A; Schwartz, Lawrence H; Taub, Robert N
2013-12-01
Intraperitoneal chemotherapy is used to treat peritoneal surface-spreading malignancies. We sought to determine whether volume and surface area of the intraperitoneal chemotherapy compartments are associated with overall survival and posttreatment glomerular filtration rate (GFR) in malignant peritoneal mesothelioma (MPM) patients. Thirty-eight MPM patients underwent X-ray computed tomography peritoneograms during outpatient intraperitoneal chemotherapy. We calculated volume and surface area of contrast-filled compartments by semiautomated computer algorithm. We tested whether these were associated with overall survival and posttreatment GFR. Decreased likelihood of mortality was associated with larger surface areas (p = 0.0201) and smaller contrast-filled compartment volumes (p = 0.0341), controlling for age, sex, histologic subtype, and presence of residual disease >0.5 cm postoperatively. Larger volumes were associated with higher posttreatment GFR, controlling for pretreatment GFR, body surface area, surface area, and the interaction between body surface area and volume (p = 0.0167). Computed tomography peritoneography is an appropriate modality to assess for maldistribution of intraperitoneal chemotherapy. In addition to identifying catheter failure and frank loculation, quantitative analysis of the contrast-filled compartment's surface area and volume may predict overall survival and cisplatin-induced nephrotoxicity. Prospective studies should be undertaken to confirm and extend these findings to other diseases, including advanced ovarian carcinoma.
V̇O2,max: what do we know, and what do we still need to know?
Levine, Benjamin D
2008-01-01
Maximal oxygen uptake is a physiological characteristic bounded by the parametric limits of the Fick equation: (left ventricular (LV) end-diastolic volume − LV end-systolic volume) × heart rate × arterio-venous oxygen difference. ‘Classical’ views of emphasize its critical dependence on convective oxygen transport to working skeletal muscle, and recent data are dispositive, proving convincingly that such limits must and do exist. ‘Contemporary’ investigations into the mechanisms underlying peripheral muscle fatigue due to energetic supply/demand mismatch are clarifying the local mediators of fatigue at the skeletal muscle level, though the afferent signalling pathways that communicate these environmental conditions to the brain and the sites of central integration of cardiovascular and neuromotor control are still being worked out. Elite endurance athletes have a high due primarily to a high cardiac output from a large compliant cardiac chamber (including the myocardium and pericardium) which relaxes quickly and fills to a large end-diastolic volume. This large capacity for LV filling and ejection allows preservation of blood pressure during extraordinary rates of muscle blood flow and oxygen transport which support high rates of sustained oxidative metabolism. The magnitude and mechanisms of cardiac phenotype plasticity remain uncertain and probably involve underlying genetic factors, as well as the length, duration, type, intensity and age of initiation of the training stimulus PMID:18006574
Pawar, Ajinkya M; Thakur, Bhagyashree; Metzger, Zvi; Kfir, Anda; Pawar, Mansing
2016-01-01
Aim: The current ex vivo study compared the efficacy of removing root fillings using ProTaper retreatment files followed by either WaveOne reciprocating file or the Self-Adjusting File (SAF). Materials and Methods: Forty maxillary canines with single oval root canal were selected and sectioned to obtain 18-mm root segments. The root canals were instrumented with WaveOne primary files, followed by obturation using warm lateral compaction, and the sealer was allowed to fully set. The teeth were then divided into two equal groups (N = 20). Initial removal of the bulk of root filling material was performed with ProTaper retreatment files, followed by either WaveOne files (Group 1) or SAF (Group 2). Endosolv R was used as a gutta-percha softener. Preoperative and postoperative high-resolution cone-beam computed tomography (CBCT) was used to measure the volume of the root filling residue that was left after the procedure. Statistical analysis was performed using t-test. Results: The mean volume of root filling residue in Group 1 was 9.4 (±0.5) mm3, whereas in Group 2 the residue volume was 2.6 (±0.4) mm3, (P < 0.001; t-test). Conclusions: When SAF was used after ProTaper retreatment files, significantly less root filling residue was left in the canals compared to when WaveOne was used. PMID:26957798
Correlation effects in nanoparticle composites: Percolation, packing and tunneling
NASA Astrophysics Data System (ADS)
Mukherjee, Rupam
Percolation is one of the most fundamental and far-reaching physical phenomena, with major implications in a vast variety of fields. The work described in this thesis aims to understand the role of percolation effects in various, seemingly unrelated phenomena, such as the dielectric permittivity of metal-insulator composites, tunneling percolation, and the relationship between percolation and filling factors. Specifically, we investigated 1) the very large enhancement of the dielectric permittivity of a composite metal -- insulator system, RuO2 - CaCu3Ti4O12 (CCTO) near the percolation threshold. For RuO2/CCTO composites, an increase in the real part of the dielectric permittivity (initially about 10 3-104 at 10 kHz) by approximately an order of magnitude is observed in the vicinity of the percolation threshold. 2) In the same system, apart from a classical percolation transition associated with the appearance of a continuous conductance path through RuO2 nanoparticles, at least two additional tunneling percolation transitions are detected. Such behavior is consistent with the recently emerged picture of a quantum conductivity staircase, which predicts several percolation tunneling thresholds in a system with a hierarchy of local tunneling conductance, due to various degrees of proximity of adjacent conducting particles distributed in an insulating matrix. 3) The filling factors of the composites of nanoparticles with different shapes have been studied as a function of volume fraction. Interestingly, like percolation, filling factors also obey critical power law behavior as a function of size ratio of constituent particles.
Nagle, Anna S.; Speich, John E.; De Wachter, Stefan G.; Ghamarian, Peter P.; Le, David M.; Colhoun, Andrew F.; Ratz, Paul H.; Barbee, Robert W.; Klausner, Adam P.
2016-01-01
AIMS The purpose of this investigation was to develop a non-invasive, objective, and unprompted method to characterize real-time bladder sensation. METHODS Volunteers with and without overactive bladder (OAB) were prospectively enrolled in a preliminary accelerated hydration study. Participants drank 2L Gatorade-G2® and recorded real-time sensation (0–100% scale) and standardized verbal sensory thresholds using a novel, touch-screen “sensation meter.” 3D bladder ultrasound images were recorded throughout fillings for a subset of participants. Sensation data were recorded for two consecutive complete fill-void cycles. RESULTS Data from 14 normal and 12 OAB participants were obtained (ICIq-OAB-5a = 0 vs. ≥3). Filling duration decreased in fill2 compared to fill1, but volume did not significantly change. In normals, adjacent verbal sensory thresholds (within fill) showed no overlap, and identical thresholds (between fill) were similar, demonstrating effective differentiation between degrees of %bladder capacity. In OAB, within-fill overlaps and between-fill differences were identified. Real-time %capacity-sensation curves left shifted from fill1 to fill2 in normals, consistent with expected viscoelastic behavior, but unexpectedly right shifted in OAB. 3D ultrasound volume data showed that fill rates started slowly and ramped up with variable end points. CONCLUSIONS This study establishes a non-invasive means to evaluate real-time bladder sensation using a two-fill accelerated hydration protocol and a sensation meter. Verbal thresholds were inconsistent in OAB, and the right shift in OAB %capacity–sensation curve suggests potential biomechanical and/or sensitization changes. This methodology could be used to gain valuable information on different forms of OAB in a completely non-invasive way. PMID:27654469
Nagle, Anna S; Speich, John E; De Wachter, Stefan G; Ghamarian, Peter P; Le, David M; Colhoun, Andrew F; Ratz, Paul H; Barbee, Robert W; Klausner, Adam P
2017-06-01
The purpose of this investigation was to develop a non-invasive, objective, and unprompted method to characterize real-time bladder sensation. Volunteers with and without overactive bladder (OAB) were prospectively enrolled in a preliminary accelerated hydration study. Participants drank 2L Gatorade-G2® and recorded real-time sensation (0-100% scale) and standardized verbal sensory thresholds using a novel, touch-screen "sensation meter." 3D bladder ultrasound images were recorded throughout fillings for a subset of participants. Sensation data were recorded for two consecutive complete fill-void cycles. Data from 14 normal and 12 OAB participants were obtained (ICIq-OAB-5a = 0 vs. ≥3). Filling duration decreased in fill2 compared to fill1, but volume did not significantly change. In normals, adjacent verbal sensory thresholds (within fill) showed no overlap, and identical thresholds (between fill) were similar, demonstrating effective differentiation between degrees of %bladder capacity. In OAB, within-fill overlaps and between-fill differences were identified. Real-time %capacity-sensation curves left shifted from fill1 to fill2 in normals, consistent with expected viscoelastic behavior, but unexpectedly right shifted in OAB. 3D ultrasound volume data showed that fill rates started slowly and ramped up with variable end points. This study establishes a non-invasive means to evaluate real-time bladder sensation using a two-fill accelerated hydration protocol and a sensation meter. Verbal thresholds were inconsistent in OAB, and the right shift in OAB %capacity-sensation curve suggests potential biomechanical and/or sensitization changes. This methodology could be used to gain valuable information on different forms of OAB in a completely non-invasive way. © 2016 Wiley Periodicals, Inc.
7 CFR 916.350 - California Nectarine Container and Pack Regulation.
Code of Federal Regulations, 2010 CFR
2010-01-01
... box of loose-filled nectarines shall bear on one outside end, in plain sight and in plain letters, the...: Provided, That nectarines in any such volume-filled container need only be filled to within one-inch of the top of the container. (2) Each package or container of nectarines shall bear, on one outside end in...
7 CFR 916.350 - California Nectarine Container and Pack Regulation.
Code of Federal Regulations, 2011 CFR
2011-01-01
... box of loose-filled nectarines shall bear on one outside end, in plain sight and in plain letters, the...: Provided, That nectarines in any such volume-filled container need only be filled to within one-inch of the top of the container. (2) Each package or container of nectarines shall bear, on one outside end in...
46 CFR 38.15-1 - Filling of tanks-TB/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
... which tank may be loaded. V=volume of tank. d r=density of cargo at the temperature required for a cargo vapor pressure equal to the relief valve setting. d L=density of cargo at the loading temperature and pressure. (b) Nonrefrigerated tanks shall be filled so that their filling densities shall not exceed the...
46 CFR 38.15-1 - Filling of tanks-TB/ALL.
Code of Federal Regulations, 2013 CFR
2013-10-01
... which tank may be loaded. V=volume of tank. d r=density of cargo at the temperature required for a cargo vapor pressure equal to the relief valve setting. d L=density of cargo at the loading temperature and pressure. (b) Nonrefrigerated tanks shall be filled so that their filling densities shall not exceed the...
46 CFR 38.15-1 - Filling of tanks-TB/ALL.
Code of Federal Regulations, 2014 CFR
2014-10-01
... which tank may be loaded. V=volume of tank. d r=density of cargo at the temperature required for a cargo vapor pressure equal to the relief valve setting. d L=density of cargo at the loading temperature and pressure. (b) Nonrefrigerated tanks shall be filled so that their filling densities shall not exceed the...
46 CFR 38.15-1 - Filling of tanks-TB/ALL.
Code of Federal Regulations, 2012 CFR
2012-10-01
... which tank may be loaded. V=volume of tank. d r=density of cargo at the temperature required for a cargo vapor pressure equal to the relief valve setting. d L=density of cargo at the loading temperature and pressure. (b) Nonrefrigerated tanks shall be filled so that their filling densities shall not exceed the...
In situ DMSO hydration measurements of HTS compound libraries.
Ellson, R; Stearns, R; Mutz, M; Brown, C; Browning, B; Harris, D; Qureshi, S; Shieh, J; Wold, D
2005-09-01
Compounds used in high throughput screening (HTS) are typically dissolved in DMSO. These solutions are stored automation-friendly racks of wells or tubes. DMSO is hygroscopic and quickly absorbs water from the atmosphere. When present in DMSO compound solutions, water can accelerate degradation and precipitation. Understanding DMSO hydration in an HTS compound library can improve storage and screening methods by managing the impact of water on compound stability. A non-destructive, acoustic method compatible with HTS has been developed to measure water content in DMSO solutions. Performance of this acoustic method was compared with an optical technique and found to be in good agreement. The accuracy and precision of acoustic measurements was shown to be under 3% over the tested range of DMSO solutions (0% to 35% water by volume) and insensitive to the presence of HTS compounds at typical storage concentrations. Time course studies of hydration for wells in 384-well and 1536-well microplates were performed. Well geometry, fluid volume, well position and atmospheric conditions were all factors in hydration rate. High rates of hydration were seen in lower-volume fills, higher-density multi-well plates and when there was a large differential between the humidity of the lab and the water content of the DMSO. For example, a 1536-well microplate filled with 2microL of 100% DMSO exposed for one hour to a laboratory environment with approximately 40% relative humidity will absorb over 6% water by volume. Understanding DMSO hydration rates as well as the ability to reverse library hydration are important steps towards managing stability and availability of compound libraries.
Niederquell, Andreas; Kuentz, Martin
2011-03-01
These days an alternative to soft capsules is liquid-filled hard capsules. Their filling technology was investigated earlier with highly viscous formulations, while hardly any academic research focused on low-viscosity systems. Accordingly, this work addressed the filling of such oils that are splashing during the dosing process. It was aimed to first study capsule filling, using middle-chain triglycerides as reference oil, in order to then evaluate the concept of a new theoretical splashing degree for different oils. A laboratory-scale filling machine was used that included capsule sealing. Thus, the liquid encapsulation by microspray technology was employed to seal the dosage form. As a result of the study with reference oil, the filling volume and the temperature were found to be significant for the rate of leaking capsules. The filling volume was also important for weight variability of the capsules. However, most critical for this variability was the diameter of the filling nozzle. We proposed a power law for the coefficient of weight variability as a function of the nozzle diameter and the obtained exponent agreed with the proposed theory. Subsequently, a comparison of different oils revealed that the relative splashing degree shared a correlation with the coefficient of the capsule weight variability (Pearson product moment correlation of r=0.990). The novel theoretical concept was therefore found to be predictive for weight variability of the filled capsules. Finally, guidance was provided for the process development of liquid-filled capsules using low-viscosity oils. © 2011 American Association of Pharmaceutical Scientists
Kozomara, Marko; Mehnert, Ulrich; Seifert, Burkhardt; Kessler, Thomas M
2018-01-01
We investigated whether detrusor contraction during rapid bladder filling is provoked by cold or warm water. Patients with neurogenic lower urinary tract dysfunction were included in this randomized, controlled, double-blind trial. At the end of a standard urodynamic investigation patients underwent 2 bladder fillings using a 4C ice water test or a 36C warm water test saline solution at a filling speed of 100 ml per minute. The order was randomly selected, and patients and investigators were blinded to the order. The primary outcome measure was detrusor overactivity, maximum detrusor pressure and maximum bladder filling volume during the ice and warm water tests. Nine women and 31 men were the subject of data analysis. Neurogenic lower urinary tract dysfunction was caused by spinal cord injury in 33 patients and by another neurological disorder in 7. Irrespective of test order detrusor overactivity occurred significantly more often during the ice water test than during the warm water test (30 of 40 patients or 75% vs 25 of 40 or 63%, p = 0.02). When comparing the ice water test to the warm water test, maximum detrusor pressure was significantly higher and maximum bladder filling volume was significantly lower during the ice water test (each p <0.001). The order of performing the tests (ice water first vs warm water first) had no effect on the parameters. Our findings imply that the more frequent detrusor overactivity, higher maximum detrusor pressure and lower bladder filling volume during the ice water test compared to the warm water test were caused by cold water. This underlies the theory of a C-fiber mediated bladder cooling reflex in humans. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
[Comparison of wear resistance and flexural strength of three kinds of bulk-fill composite resins].
Zhang, Huan; Zhang, Meng-Long; Qiu, Li-Hong; Yu, Jing-Tao; Zhan, Fu-Liang
2016-06-01
To compare the abrasion resistance and flexure strength of three bulk-fill resin composites with an universal nano-hybrid composite resins. The specimens were prepared with three kinds of bulk fill composites (SDR , sonicfill, Tetric N-Ceram Bulk Fill) and an universal nano-hybrid composite resins(Herculite Precis). 10 mm in diameter × 2mm in height specimens were prepared for abrasion resistance, while 2 mm in width × 2 mm in depth×25 mm in length specimens were prepared for flexure strength. The specimens were mounted in a bal1-on-disc wear testing machine and abraded with the media artificial saliva(50 N loads, 10000 cycles).Flexural test was performed with an Universal Testing Machine at a cross-head speed of 1mm/min. One-way variance analysis was used to determine the statistical differences of volume loss and flexural strength among groups with SPSS 13.0 software package(P<0.05). The volume loss was as follows: SDR (1.2433±0.11) mm3
Crack propagation and arrest in pressurized containers
NASA Technical Reports Server (NTRS)
Erdogan, F.; Delale, F.; Owczarek, J. A.
1976-01-01
The problem of crack propagation and arrest in a finite volume cylindrical container filled with pressurized gas is considered. It is assumed that the cylinder contains a symmetrically located longitudinal part-through crack with a relatively small net ligament. The net ligament suddenly ruptures initiating the process of fracture propagation and depressurization in the cylinder. Thus the problem is a coupled gas dynamics and solid mechanics problem the exact formulation of which does not seem to be possible. The problem is reduced to a proper initial value problem by introducing a dynamic fracture criterion which relates the crack acceleration to the difference between a load factor and the corresponding strength parameter. The results indicate that generally in gas filled cylinders fracture arrest is not possible unless the material behaves in a ductile manner and the container is relatively long.
Is Doppler tissue velocity during early left ventricular filling preload independent?
NASA Technical Reports Server (NTRS)
Yalcin, F.; Kaftan, A.; Muderrisoglu, H.; Korkmaz, M. E.; Flachskampf, F.; Garcia, M.; Thomas, J. D.
2002-01-01
BACKGROUND: Transmitral Doppler flow indices are used to evaluate diastolic function. Recently, velocities measured by Doppler tissue imaging have been used as an index of left ventricular relaxation. OBJECTIVE: To determine whether Doppler tissue velocities are influenced by alterations in preload. METHODS: Left ventricular preload was altered in 17 patients (all men, mean (SD) age, 49 (8) years) during echocardiographic measurements of left ventricular end diastolic volume, maximum left atrial area, peak early Doppler filling velocity, and left ventricular myocardial velocities during early filling. Preload altering manoeuvres included Trendelenberg (stage 1), reverse Trendelenberg (stage 2), and amyl nitrate (stage 3). Systolic blood pressure was measured at each stage. RESULTS: In comparison with baseline, left ventricular end diastolic volume (p = 0.001), left atrial area (p = 0.003), peak early mitral Doppler filling velocity (p = 0.01), and systolic blood pressures (p = 0.001) were all changed by preload altering manoeuvres. Only left ventricular myocardial velocity during early filling remained unchanged by these manoeuvres. CONCLUSIONS: In contrast to standard transmitral Doppler filling indices, Doppler tissue early diastolic velocities are not significantly affected by physiological manoeuvres that alter preload. Thus Doppler tissue velocities during early left ventricular diastole may provide a better index of diastolic function in cardiac patients by providing a preload independent assessment of left ventricular filling.
Fluid dynamics following flow shut-off in bottle filling
NASA Astrophysics Data System (ADS)
Thete, Sumeet; Appathurai, Santosh; Gao, Haijing; Basaran, Osman
2012-11-01
Bottle filling is ubiquitous in industry. Examples include filling of bottles with shampoos and cleaners, engine oil and pharmaceuticals. In these examples, fluid flows out of a nozzle to fill bottles in an assembly line. Once the required volume of fluid has flowed out of the nozzle, the flow is shut off. However, an evolving fluid thread or string may remain suspended from the nozzle following flow shut-off and persist. This stringing phenomenon can be detrimental to a bottle filling operation because it can adversely affect line speed and filling accuracy by causing uncertainty in fill volume, product loss and undesirable marring of the bottles' exterior surfaces. The dynamics of stringing are studied numerically primarily by using the 1D, slender-jet approximation of the flow equations. A novel feature entails development and use of a new boundary condition downstream of the nozzle exit to expedite the computations. While the emphasis is on stringing of Newtonian fluids and use of 1D approximations, results will also be presented for situations where (a) the fluids are non-Newtonian and (b) the full set of equations are solved without invoking the 1D approximation. Phase diagrams will be presented that identify conditions for which stringing can be problematic.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stewart, Alexandra J.; Cormack, Robert A.; Lee, Hang
2008-11-01
Purpose: To investigate the effect of bladder filling on dosimetry and to determine the best bladder dosimetric parameter for vaginal cuff brachytherapy. Methods and Materials: In this prospective clinical trial, a total of 20 women underwent vaginal cylinder high-dose-rate brachytherapy. The bladder was full for Fraction 2 and empty for Fraction 3. Dose-volume histogram and dose-surface histogram values were generated for the bladder, rectum, and urethra. The midline maximal bladder point (MBP) and the midline maximal rectal point were recorded. Paired t tests, Pearson correlations, and regression analyses were performed. Results: The volume and surface area of the irradiated bladdermore » were significantly smaller when the bladder was empty than when full. Of the several dose-volume histogram and dose-surface histogram parameters evaluated, the bladder maximal dose received by 2 cm{sup 3} of tissue, volume of bladder receiving {>=}50% of the dose, volume of bladder receiving {>=}70% of the dose, and surface area of bladder receiving {>=}50% of the dose significantly predicted for the difference between the empty vs. full filling state. The volume of bladder receiving {>=}70% of the dose and the maximal dose received by 2 cm{sup 3} of tissue correlated significantly with the MBP. Bladder filling did not alter the volume or surface area of the rectum irradiated. However, an empty bladder did result in the nearest point of bowel being significantly closer to the vaginal cylinder than when the bladder was full. Conclusions: Patients undergoing vaginal cuff brachytherapy treated with an empty bladder have a lower bladder dose than those treated with a full bladder. The MBP correlated well with the volumetric assessments of bladder dose and provided a noninvasive method for reporting the MBP dose using three-dimensional imaging. The MBP can therefore be used as a surrogate for complex dosimetry in the clinic.« less
Improved cardiac filling facilitates the postprandial elevation of stroke volume in Python regius.
Enok, Sanne; Leite, Gabriella S P C; Leite, Cléo A C; Gesser, Hans; Hedrick, Michael S; Wang, Tobias
2016-10-01
To accommodate the pronounced metabolic response to digestion, pythons increase heart rate and elevate stroke volume, where the latter has been ascribed to a massive and fast cardiac hypertrophy. However, numerous recent studies show that heart mass rarely increases, even upon ingestion of large meals, and we therefore explored the possibility that a rise in mean circulatory filling pressure (MCFP) serves to elevate venous pressure and cardiac filling during digestion. To this end, we measured blood flows and pressures in anaesthetized Python regius The anaesthetized snakes exhibited the archetypal tachycardia as well as a rise in both venous pressure and MCFP that fully account for the approximate doubling of stroke volume. There was no rise in blood volume and the elevated MCFP must therefore stem from increased vascular tone, possibly by means of increased sympathetic tone on the veins. Furthermore, although both venous pressure and MCFP increased during volume loading, there was no evidence that postprandial hearts were endowed with an additional capacity to elevate stroke volume. In vitro measurements of force development of paced ventricular strips also failed to reveal signs of increased contractility, but the postprandial hearts had higher activities of cytochrome oxidase and pyruvate kinase, which probably serves to sustain the rise in cardiac work during digestion. © 2016. Published by The Company of Biologists Ltd.
The G Protein-Coupled Bile Acid Receptor, TGR5, Stimulates Gallbladder Filling
Li, Tingting; Holmstrom, Sam R.; Kir, Serkan; Umetani, Michihisa; Schmidt, Daniel R.
2011-01-01
TGR5 is a G protein-coupled bile acid receptor present in brown adipose tissue and intestine, where its agonism increases energy expenditure and lowers blood glucose. Thus, it is an attractive drug target for treating human metabolic disease. However, TGR5 is also highly expressed in gallbladder, where its functions are less well characterized. Here, we demonstrate that TGR5 stimulates the filling of the gallbladder with bile. Gallbladder volume was increased in wild-type but not Tgr5−/− mice by administration of either the naturally occurring TGR5 agonist, lithocholic acid, or the synthetic TGR5 agonist, INT-777. These effects were independent of fibroblast growth factor 15, an enteric hormone previously shown to stimulate gallbladder filling. Ex vivo analyses using gallbladder tissue showed that TGR5 activation increased cAMP concentrations and caused smooth muscle relaxation in a TGR5-dependent manner. These data reveal a novel, gallbladder-intrinsic mechanism for regulating gallbladder contractility. They further suggest that TGR5 agonists should be assessed for effects on human gallbladder as they are developed for treating metabolic disease. PMID:21454404
Experimental investigation on no-vent fill process using tetrafluoromethane (CF4)
NASA Astrophysics Data System (ADS)
Kim, Youngcheol; Lee, Cheonkyu; Park, Jiho; Seo, Mansu; Jeong, Sangkwon
2016-03-01
This paper investigates the transfer of liquid cryogens using a no-vent fill (NVF) process experimentally to identify the dominant NVF parameters. The experimental apparatus has been fabricated with extensive instrumentations to precisely study the effects of each NVF parameter. Liquid tetrafluoromethane (CF4) is selected as the working fluid due to its similar molecular structures and similar normal boiling point and triple point with liquid methane which has been considered as an attractive future cryogenic propellant. The experimental results show that the initial receiver tank wall temperature and the incoming liquid temperature are the primary factors that characterize the (non-equilibrium) thermodynamic state at the start of a NVF transfer. The supply pressure is also critical as it indicates the ability to condense vapor in the receiver tank. A non-dimensional map based on energy balance is proposed to find acceptable initial conditions of the filling volume at the desired final tank pressure. The non-dimensional map shows good agreement with the NVF data not only in this paper but also in the previous research.
2012-01-01
Background In this paper a new non-invasive, operator-free, continuous ventricular stroke volume monitoring device (Hemodynamic Cardiac Profiler, HCP) is presented, that measures the average stroke volume (SV) for each period of 20 seconds, as well as ventricular volume-time curves for each cardiac cycle, using a new electric method (Ventricular Field Recognition) with six independent electrode pairs distributed over the frontal thoracic skin. In contrast to existing non-invasive electric methods, our method does not use the algorithms of impedance or bioreactance cardiography. Instead, our method is based on specific 2D spatial patterns on the thoracic skin, representing the distribution, over the thorax, of changes in the applied current field caused by cardiac volume changes during the cardiac cycle. Since total heart volume variation during the cardiac cycle is a poor indicator for ventricular stroke volume, our HCP separates atrial filling effects from ventricular filling effects, and retrieves the volume changes of only the ventricles. Methods ex-vivo experiments on a post-mortem human heart have been performed to measure the effects of increasing the blood volume inside the ventricles in isolation, leaving the atrial volume invariant (which can not be done in-vivo). These effects have been measured as a specific 2D pattern of voltage changes on the thoracic skin. Furthermore, a working prototype of the HCP has been developed that uses these ex-vivo results in an algorithm to decompose voltage changes, that were measured in-vivo by the HCP on the thoracic skin of a human volunteer, into an atrial component and a ventricular component, in almost real-time (with a delay of maximally 39 seconds). The HCP prototype has been tested in-vivo on 7 human volunteers, using G-suit inflation and deflation to provoke stroke volume changes, and LVot Doppler as a reference technique. Results The ex-vivo measurements showed that ventricular filling caused a pattern over the thorax quite distinct from that of atrial filling. The in-vivo tests of the HCP with LVot Doppler resulted in a Pearson’s correlation of R = 0.892, and Bland-Altman plotting of SV yielded a mean bias of -1.6 ml and 2SD =14.8 ml. Conclusions The results indicate that the HCP was able to track the changes in ventricular stroke volume reliably. Furthermore, the HCP produced ventricular volume-time curves that were consistent with the literature, and may be a diagnostic tool as well. PMID:22900831
7 CFR 917.442 - California Peach Container and Pack Regulation.
Code of Federal Regulations, 2011 CFR
2011-01-01
...) Each No. 22E standard lug box of loose-filled peaches shall bear on one outside end, in plain sight and... peaches in any such volume-filled container need only be filled to within one-inch of the top of the container. (2) Each package or container of peaches shall bear, on one outside end in plain sight and in...
7 CFR 917.442 - California Peach Container and Pack Regulation.
Code of Federal Regulations, 2010 CFR
2010-01-01
...) Each No. 22E standard lug box of loose-filled peaches shall bear on one outside end, in plain sight and... peaches in any such volume-filled container need only be filled to within one-inch of the top of the container. (2) Each package or container of peaches shall bear, on one outside end in plain sight and in...
Investigating Diffusion and Entropy with Carbon Dioxide-Filled Balloons
ERIC Educational Resources Information Center
Jadrich, James; Bruxvoort, Crystal
2010-01-01
Fill an ordinary latex balloon with helium gas and you know what to expect. Over the next day or two the volume will decrease noticeably as helium escapes from the balloon. So what happens when a latex balloon is filled with carbon dioxide gas? Surprisingly, carbon dioxide balloons deflate at rates as much as an order of magnitude faster than…
NASA Technical Reports Server (NTRS)
Vandresar, N. T.; Hasan, M. M.; Lin, C.-S.
1991-01-01
Experimental results are presented for the self pressurization and thermal stratification of a 4.89 cu m liquid hydrogen storage tank subjected to low heat flux (2.0 and 3.5 W/sq m) in normal gravity. The test tank was representative of future spacecraft tankage, having a low mass to volume ratio and high performance multilayer thermal insulation. Tests were performed at fill levels of 29 and 49 pcts. (by volume) and complement previous tests at 83 pct. fill. As the heat flux increases, the pressure rise rate at each fill level exceeds the homogeneous rate by an increasing ratio. Herein, this ratio did not exceed a value of 2. The slowest pressure rise rate was observed for the 49 pct. fill level at both heat fluxes. This result is attributed to the oblate spheroidal tank geometry which introduces the variables of wetted wall area, liquid-vapor interfacial area, and ratio of side wall to bottom heating as a function of fill level or liquid depth. Initial tank thermal conditions were found to affect the initial pressure rise rate. Quasi steady pressure rise rates are independent of starting conditions.
Iliev, Peter; Bhalla, Tarun; Tobias, Joseph D
2016-04-01
The Ambu Smart-Infuser Pain Pump and the On-Q Pump with Select-a-Flow Variable Rate Controller are elastomeric devices with a flow regulator that controls the rate of infusion of a local anesthetic agent through a peripheral catheter. As a safety evaluation, we evaluated the infusion characteristics of these two devices when filled with manufacturer recommended standard volumes and when overfilled with a volume 50% in excess of that which is recommended. Nineteen disposable devices from the two manufacturers were used in this study. Nine were filled with 0.9% normal saline according to the respective manufacturers' recommendations (four Ambu pumps were filled with 650 ml and five On-Q pumps were filled with 550 ml) and 10 devices were 150% overfilled (five Ambu pumps were filled with 975 ml and five On-Q pumps were filled with 825 ml). All of the devices were set to infuse at 10 ml · h(-1) at room temperature (21°C) for 12 h. The fluid delivered during each 2-h period was measured using a graduated column. The On-Q pump (in the settings of normal fill and 150% overfill) delivered a significantly higher output per hour than the set rate during the first 8 h, while the Ambu pump delivered a value close to the set rate of 10 ml · h(-1). No significant difference in the hourly delivered output was noted for either device when comparing the normal fill to the 150% overfill groups. This investigation demonstrates that no change in the hourly output occurs with overfilling of these home infusion devices. However, as noted previously, the hourly output from the On-Q device is significantly higher than the set rate during the initial 8 h of infusion which could have potential clinical implications. © 2016 John Wiley & Sons Ltd.
Dexter, F; Macario, A; Lubarsky, D A
2001-05-01
We previously studied hospitals in the United States of America that are losing money despite limiting the hours that operating room (OR) staff are available to care for patients undergoing elective surgery. These hospitals routinely keep utilization relatively high to maximize revenue. We tested, using discrete-event computer simulation, whether increasing patient volume while being reimbursed less for each additional patient can reliably achieve an increase in revenue when initial adjusted OR utilization is 90%. We found that increasing the volume of referred patients by the amount expected to fill the surgical suite (100%/90%) would increase utilization by <1% for a hospital surgical suite (with longer duration cases) and 4% for an ambulatory surgery suite (with short cases). The increase in patient volume would result in longer patient waiting times for surgery and more patients leaving the surgical queue. With a 15% reduction in payment for the new patients, the increase in volume may not increase revenue and can even decrease the contribution margin for the hospital surgical suite. The implication is that for hospitals with a relatively high OR utilization, signing discounted contracts to increase patient volume by the amount expected to "fill" the OR can have the net effect of decreasing the contribution margin (i.e., profitability). Hospitals may try to attract new surgical volume by offering discounted rates. For hospitals with a relatively high operating room utilization (e.g., 90%), computer simulations predict that increasing patient volume by the amount expected to "fill" the operating room can have the net effect of decreasing contribution margin (i.e., profitability).
Air-gas exchange reevaluated: clinically important results of a computer simulation.
Shunmugam, Manoharan; Shunmugam, Sudhakaran; Williamson, Tom H; Laidlaw, D Alistair
2011-10-21
The primary aim of this study was to evaluate the efficiency of air-gas exchange techniques and the factors that influence the final concentration of an intraocular gas tamponade. Parameters were varied to find the optimum method of performing an air-gas exchange in ideal circumstances. A computer model of the eye was designed using 3D software with fluid flow analysis capabilities. Factors such as angular distance between ports, gas infusion gauge, exhaust vent gauge and depth were varied in the model. Flow rate and axial length were also modulated to simulate faster injections and more myopic eyes, respectively. The flush volume of gas required to achieve a 97% intraocular gas fraction concentration were compared. Modulating individual factors did not reveal any clinically significant difference in the angular distance between ports, exhaust vent size, and depth or rate of gas injection. In combination, however, there was a 28% increase in air-gas exchange efficiency comparing the most efficient with the least efficient studied parameters in this model. The gas flush volume required to achieve a 97% gas fill also increased proportionately at a ratio of 5.5 to 6.2 times the volume of the eye. A 35-mL flush is adequate for eyes up to 25 mm in axial length; however, eyes longer than this would require a much greater flush volume, and surgeons should consider using two separate 50-mL gas syringes to ensure optimal gas concentration for eyes greater than 25 mm in axial length.
Akbulut, Makbule Bilge; Akman, Melek; Terlemez, Arslan; Magat, Guldane; Sener, Sevgi; Shetty, Heeresh
2016-01-01
The aim of this study was to evaluate the efficacy of Twisted File (TF) Adaptive, Reciproc, and ProTaper Universal Retreatment (UR) System instruments for removing root-canal-filling. Sixty single rooted teeth were decoronated, instrumented and obturated. Preoperative CBCT scans were taken and the teeth were retreated with TF Adaptive, Reciproc, ProTaper UR, or hand files (n=15). Then, the teeth were rescanned, and the percentage volume of the residual root-canal-filling material was established. The total time for retreatment was recorded, and the data was statistically analyzed. The statistical ranking of the residual filling material volume was as follows: hand file=TF Adaptive>ProTaper UR=Reciproc. The ProTaper UR and Reciproc systems required shorter periods of time for retreatment. Root canal filling was more efficiently removed by using Reciproc and ProTaper UR instruments than TF Adaptive instruments and hand files. The TF Adaptive system was advantageous over hand files with regard to operating time.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stelljes, T.S.; Looe, H.K.; Poppe, B.
Purpose: To present a general definition of the fill factor realistically characterizing the “field coverage”, i.e. the MLC misalignment detection capabilities of a detector array. Methods: According to Gago-Arias et al.{sup 1} the fill factor of a 2D array is defined as the ratio of the area enclosed by the FWHM of the fluence response function KM(x) of a single detector and its cell area defined by the detector spacing. More generally - accounting also for the possible overlap between FWHM’s of neighboured detectors - the fill factor is here defined as that fraction of the sum of the detectormore » cell areas in which a defined MLC misalignment is detectable when the induced percentage signal changes exceed a detection threshold d. Ideally the generalized fill factor may reach 100 %. With user code EGS-chamber and a 2 MeV photon slit beam 0.25 mm wide, both types of the fill factor were calculated for an array with total cell area 100 cm{sup 2} for chamber widths 1–9 mm, using =1mm, d=5%. Results: For single chamber width 5 mm, fill factors were 0.49 (FWHM) and 0.61 (generalized). For chamber width 2 mm the FWHM fill factor was 0.13 whereas the generalized fill factor was 0.32. For chamber widths above 7 mm, the FWHM fill factor exceeds unity, and the general fill factor is exactly 1.00. Conclusions: An updated fill factor definition is introduced which, as a generalization of the FWHM-based definition, more closely estimates the performance of small array chambers and gives a realistic value in the case of overlapping sensitive areas of neighboured chambers. References:{sup 1}A. Gago-Arias, L. Brualla-Gonzalez, D.M. Gonzalez-Castano, F. Gomez, M.S. Garcia, V.L. Vega, J.M. Sueiro, J. Pardo-Montero, “Evaluation of chamber response function influence on IMRT verification using 2D commercial detector arrays,” Phys. Med. Biol. 57, 2005–2020 (2012)« less
High throughput nanoimprint lithography for semiconductor memory applications
NASA Astrophysics Data System (ADS)
Ye, Zhengmao; Zhang, Wei; Khusnatdinov, Niyaz; Stachowiak, Tim; Irving, J. W.; Longsine, Whitney; Traub, Matthew; Fletcher, Brian; Liu, Weijun
2017-03-01
Imprint lithography is a promising technology for replication of nano-scale features. For semiconductor device applications, Canon deposits a low viscosity resist on a field by field basis using jetting technology. A patterned mask is lowered into the resist fluid which then quickly flows into the relief patterns in the mask by capillary action. Following this filling step, the resist is crosslinked under UV radiation, and then the mask is removed, leaving a patterned resist on the substrate. There are two critical components to meeting throughput requirements for imprint lithography. Using a similar approach to what is already done for many deposition and etch processes, imprint stations can be clustered to enhance throughput. The FPA-1200NZ2C is a four station cluster system designed for high volume manufacturing. For a single station, throughput includes overhead, resist dispense, resist fill time (or spread time), exposure and separation. Resist exposure time and mask/wafer separation are well understood processing steps with typical durations on the order of 0.10 to 0.20 seconds. To achieve a total process throughput of 17 wafers per hour (wph) for a single station, it is necessary to complete the fluid fill step in 1.2 seconds. For a throughput of 20 wph, fill time must be reduced to only one 1.1 seconds. There are several parameters that can impact resist filling. Key parameters include resist drop volume (smaller is better), system controls (which address drop spreading after jetting), Design for Imprint or DFI (to accelerate drop spreading) and material engineering (to promote wetting between the resist and underlying adhesion layer). In addition, it is mandatory to maintain fast filling, even for edge field imprinting. In this paper, we address the improvements made in all of these parameters to first enable a 1.20 second filling process for a device like pattern and have demonstrated this capability for both full fields and edge fields. Non-fill defectivity is well under 1.0 defects/cm2 for both field types. Next, by further reducing drop volume and optimizing drop patterns, a fill time of 1.1 seconds was demonstrated.
A multifractal approach to space-filling recovery for PET quantification.
Willaime, Julien M Y; Aboagye, Eric O; Tsoumpas, Charalampos; Turkheimer, Federico E
2014-11-01
A new image-based methodology is developed for estimating the apparent space-filling properties of an object of interest in PET imaging without need for a robust segmentation step and used to recover accurate estimates of total lesion activity (TLA). A multifractal approach and the fractal dimension are proposed to recover the apparent space-filling index of a lesion (tumor volume, TV) embedded in nonzero background. A practical implementation is proposed, and the index is subsequently used with mean standardized uptake value (SUV mean) to correct TLA estimates obtained from approximate lesion contours. The methodology is illustrated on fractal and synthetic objects contaminated by partial volume effects (PVEs), validated on realistic (18)F-fluorodeoxyglucose PET simulations and tested for its robustness using a clinical (18)F-fluorothymidine PET test-retest dataset. TLA estimates were stable for a range of resolutions typical in PET oncology (4-6 mm). By contrast, the space-filling index and intensity estimates were resolution dependent. TLA was generally recovered within 15% of ground truth on postfiltered PET images affected by PVEs. Volumes were recovered within 15% variability in the repeatability study. Results indicated that TLA is a more robust index than other traditional metrics such as SUV mean or TV measurements across imaging protocols. The fractal procedure reported here is proposed as a simple and effective computational alternative to existing methodologies which require the incorporation of image preprocessing steps (i.e., partial volume correction and automatic segmentation) prior to quantification.
Stöhr, Eric J; González-Alonso, José; Pearson, James; Low, David A; Ali, Leena; Barker, Horace; Shave, Rob
2011-09-01
The purpose of this study was to determine whether the reduction in stroke volume (SV), previously shown to occur with dehydration and increases in internal body temperatures during prolonged exercise, is caused by a reduction in left ventricular (LV) function, as indicated by LV volumes, strain, and twist ("LV mechanics"). Eight healthy men [age: 20 ± 2, maximal oxygen uptake (VO₂max): 58 ± 7 ml·kg⁻¹·min⁻¹] completed two, 1-h bouts of cycling in the heat (35°C, 50% peak power) without fluid replacement, resulting in 2% and 3.5% dehydration, respectively. Conventional and two-dimensional speckle-tracking echocardiography was used to determine LV volumes, strain, and twist at rest and during one-legged knee-extensor exercise at baseline, both levels of dehydration, and following rehydration. Progressive dehydration caused a significant reduction in end-diastolic volume (EDV) and SV at rest and during one-legged knee-extensor exercise (rest: Δ-33 ± 14 and Δ-21 ± 14 ml, respectively; exercise: Δ-30 ± 10 and Δ-22 ± 9 ml, respectively, during 3.5% dehydration). In contrast to the marked decline in EDV and SV, systolic and diastolic LV mechanics were either maintained or even enhanced with dehydration at rest and during knee-extensor exercise. We conclude that dehydration-induced reductions in SV at rest and during exercise are the result of reduced LV filling, as reflected by the decline in EDV. The concomitant maintenance of LV mechanics suggests that the decrease in LV filling, and consequently ejection, is likely caused by the reduction in blood volume and/or diminished filling time rather than impaired LV function.
Acoustic fill factors for a 120 inch diameter fairing
NASA Technical Reports Server (NTRS)
Lee, Y. Albert
1992-01-01
Data from the acoustic test of a 120-inch diameter payload fairing were collected and an analysis of acoustic fill factors were performed. Correction factors for obtaining a weighted spatial average of the interior sound pressure level (SPL) were derived based on this database and a normalized 200-inch diameter fairing database. The weighted fill factors were determined and compared with statistical energy analysis (VAPEPS code) derived fill factors. The comparison is found to be reasonable.
Molded underfill (MUF) encapsulation for flip-chip package: A numerical investigation
NASA Astrophysics Data System (ADS)
Azmi, M. A.; Abdullah, M. K.; Abdullah, M. Z.; Ariff, Z. M.; Saad, Abdullah Aziz; Hamid, M. F.; Ismail, M. A.
2017-07-01
This paper presents the numerical simulation of epoxy molding compound (EMC) filling in multi flip-chip packages during encapsulation process. The empty and a group flip chip packages were considered in the mold cavity in order to study the flow profile of the EMC. SOLIDWORKS software was used for three-dimensional modeling and it was incorporated into fluid analysis software namely as ANSYS FLUENT. The volume of fluid (VOF) technique was used for capturing the flow front profiles and Power Law model was applied for its rheology model. The numerical result are compared and discussed with previous experimental and it was shown a good conformity for model validation. The prediction of flow front was observed and analyzed at different filling time. The possibility and visual of void formation in the package is captured and the number of flip-chip is one factor that contributed to the void formation.
Min, Yi; Song, Ying; Gao, Yuan; Dummer, Paul M H
2016-08-01
This study aimed to present a new method based on numeric calculus to provide data on the theoretical volume ratio of voids when using the cold lateral compaction technique in canals with various diameters and tapers. Twenty-one simulated mathematical root canal models were created with different tapers and sizes of apical diameter, and were filled with defined sizes of standardized accessory gutta-percha cones. The areas of each master and accessory gutta-percha cone as well as the depth of their insertion into the canals were determined mathematically in Microsoft Excel. When the first accessory gutta-percha cone had been positioned, the residual area of void was measured. The areas of the residual voids were then measured repeatedly upon insertion of additional accessary cones until no more could be inserted in the canal. The volume ratio of voids was calculated through measurement of the volume of the root canal and mass of gutta-percha cones. The theoretical volume ratio of voids was influenced by the taper of canal, the size of apical preparation and the size of accessory gutta-percha cones. Greater apical preparation size and larger taper together with the use of smaller accessory cones reduced the volume ratio of voids in the apical third. The mathematical model provided a precise method to determine the theoretical volume ratio of voids in root-filled canals when using cold lateral compaction.
Rouse-Bueche Theory and The Calculation of The Monomeric Friction Coefficient in a Filled System
NASA Astrophysics Data System (ADS)
Martinetti, Luca; Macosko, Christopher; Bates, Frank
According to flexible chain theories of viscoelasticity, all relaxation and retardation times of a polymer melt (hence, any dynamic property such as the diffusion coefficient) depend on the monomeric friction coefficient, ζ0, i.e. the average drag force per monomer per unit velocity encountered by a Gaussian submolecule moving through its free-draining surroundings. Direct experimental access to ζ0 relies on the availability of a suitable polymer dynamics model. Thus far, no method has been suggested that is applicable to filled systems, such as filled rubbers or microphase-segregated A-B-A thermoplastic elastomers at temperatures where one of the blocks is glassy. Building upon the procedure proposed by Ferry for entangled and unfilled polymer melts, the Rouse-Bueche theory is applied to an undiluted triblock copolymer to extract ζ0 from the linear viscoelastic behavior in the rubber-glass transition region, and to estimate the size of Gaussian submolecules. At iso-free volume conditions, the so-obtained matrix monomeric friction factor is consistent with the corresponding value for the homopolymer melt. In addition, the characteristic Rouse dimensions are in good agreement with independent estimates based on the Kratky-Porod worm-like chain model. These results seem to validate the proposed approach for estimating ζ0 in a filled system. Although preliminary tested on a thermoplastic elastomer of the A-B-A type, the method may be extended and applied to filled homopolymers as well.
NASA Astrophysics Data System (ADS)
Suntako, R.
2018-01-01
Zinc oxide (ZnO) is widely used in rubber industry as a cure activator for rubber vulcanization. In this work, comparison of cure characteristic, mechanical properties, thermal conductivity and volume swell testing in oil no.1 and oil no.3 between natural rubber (NR) filled synthesized ZnO nanoparticles (sZnO) by precipitation method and NR filled conventional ZnO (cZnO). The particle size of sZnO is 41.50 nm and specific area of 27.92 m2/g, the particle size of cZnO is 312.92 nm and specific surface area of 1.35 m2/g. It has been found that NR filled sZnO not only improves rubber mechanical properties, volume swell testing but also improves thermal conductivity and better than NR filled cZnO. Thermal conductivity of NR filled sZnO increases by 10.34%, 12.90% and 20.00%, respectively when compared with NR filled cZnO in same loading content (various concentrations of ZnO at 5, 8 and 10 parts per hundred parts of rubber). This is due to small particle size and large specific surface area of sZnO which lead to an increase in crosslinking in rubber chain and enhance heat transfer performance.
NASA Astrophysics Data System (ADS)
Wierts, R.; Jentzen, W.; Quick, H. H.; Wisselink, H. J.; Pooters, I. N. A.; Wildberger, J. E.; Herrmann, K.; Kemerink, G. J.; Backes, W. H.; Mottaghy, F. M.
2018-01-01
The aim was to investigate the quantitative performance of 124I PET/MRI for pre-therapy lesion dosimetry in differentiated thyroid cancer (DTC). Phantom measurements were performed on a PET/MRI system (Biograph mMR, Siemens Healthcare) using 124I and 18F. The PET calibration factor and the influence of radiofrequency coil attenuation were determined using a cylindrical phantom homogeneously filled with radioactivity. The calibration factor was 1.00 ± 0.02 for 18F and 0.88 ± 0.02 for 124I. Near the radiofrequency surface coil an underestimation of less than 5% in radioactivity concentration was observed. Soft-tissue sphere recovery coefficients were determined using the NEMA IEC body phantom. Recovery coefficients were systematically higher for 18F than for 124I. In addition, the six spheres of the phantom were segmented using a PET-based iterative segmentation algorithm. For all 124I measurements, the deviations in segmented lesion volume and mean radioactivity concentration relative to the actual values were smaller than 15% and 25%, respectively. The effect of MR-based attenuation correction (three- and four-segment µ-maps) on bone lesion quantification was assessed using radioactive spheres filled with a K2HPO4 solution mimicking bone lesions. The four-segment µ-map resulted in an underestimation of the imaged radioactivity concentration of up to 15%, whereas the three-segment µ-map resulted in an overestimation of up to 10%. For twenty lesions identified in six patients, a comparison of 124I PET/MRI to PET/CT was performed with respect to segmented lesion volume and radioactivity concentration. The interclass correlation coefficients showed excellent agreement in segmented lesion volume and radioactivity concentration (0.999 and 0.95, respectively). In conclusion, it is feasible that accurate quantitative 124I PET/MRI could be used to perform radioiodine pre-therapy lesion dosimetry in DTC.
A multifractal approach to space-filling recovery for PET quantification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Willaime, Julien M. Y., E-mail: julien.willaime@siemens.com; Aboagye, Eric O.; Tsoumpas, Charalampos
2014-11-01
Purpose: A new image-based methodology is developed for estimating the apparent space-filling properties of an object of interest in PET imaging without need for a robust segmentation step and used to recover accurate estimates of total lesion activity (TLA). Methods: A multifractal approach and the fractal dimension are proposed to recover the apparent space-filling index of a lesion (tumor volume, TV) embedded in nonzero background. A practical implementation is proposed, and the index is subsequently used with mean standardized uptake value (SUV {sub mean}) to correct TLA estimates obtained from approximate lesion contours. The methodology is illustrated on fractal andmore » synthetic objects contaminated by partial volume effects (PVEs), validated on realistic {sup 18}F-fluorodeoxyglucose PET simulations and tested for its robustness using a clinical {sup 18}F-fluorothymidine PET test–retest dataset. Results: TLA estimates were stable for a range of resolutions typical in PET oncology (4–6 mm). By contrast, the space-filling index and intensity estimates were resolution dependent. TLA was generally recovered within 15% of ground truth on postfiltered PET images affected by PVEs. Volumes were recovered within 15% variability in the repeatability study. Results indicated that TLA is a more robust index than other traditional metrics such as SUV {sub mean} or TV measurements across imaging protocols. Conclusions: The fractal procedure reported here is proposed as a simple and effective computational alternative to existing methodologies which require the incorporation of image preprocessing steps (i.e., partial volume correction and automatic segmentation) prior to quantification.« less
Estimation of Image Sensor Fill Factor Using a Single Arbitrary Image
Wen, Wei; Khatibi, Siamak
2017-01-01
Achieving a high fill factor is a bottleneck problem for capturing high-quality images. There are hardware and software solutions to overcome this problem. In the solutions, the fill factor is known. However, this is an industrial secrecy by most image sensor manufacturers due to its direct effect on the assessment of the sensor quality. In this paper, we propose a method to estimate the fill factor of a camera sensor from an arbitrary single image. The virtual response function of the imaging process and sensor irradiance are estimated from the generation of virtual images. Then the global intensity values of the virtual images are obtained, which are the result of fusing the virtual images into a single, high dynamic range radiance map. A non-linear function is inferred from the original and global intensity values of the virtual images. The fill factor is estimated by the conditional minimum of the inferred function. The method is verified using images of two datasets. The results show that our method estimates the fill factor correctly with significant stability and accuracy from one single arbitrary image according to the low standard deviation of the estimated fill factors from each of images and for each camera. PMID:28335459
Measurement of absolute regional lung air volumes from near-field x-ray speckles.
Leong, Andrew F T; Paganin, David M; Hooper, Stuart B; Siew, Melissa L; Kitchen, Marcus J
2013-11-18
Propagation-based phase contrast x-ray (PBX) imaging yields high contrast images of the lung where airways that overlap in projection coherently scatter the x-rays, giving rise to a speckled intensity due to interference effects. Our previous works have shown that total and regional changes in lung air volumes can be accurately measured from two-dimensional (2D) absorption or phase contrast images when the subject is immersed in a water-filled container. In this paper we demonstrate how the phase contrast speckle patterns can be used to directly measure absolute regional lung air volumes from 2D PBX images without the need for a water-filled container. We justify this technique analytically and via simulation using the transport-of-intensity equation and calibrate the technique using our existing methods for measuring lung air volume. Finally, we show the full capabilities of this technique for measuring regional differences in lung aeration.
Cavenago, B C; Ordinola-Zapata, R; Duarte, M A H; del Carpio-Perochena, A E; Villas-Bôas, M H; Marciano, M A; Bramante, C M; Moraes, I G
2014-11-01
To evaluate the volume of remaining filling material in the mesial root canals of mandibular molars after root canal retreatment with different procedures performed sequentially. The mesial root canals of 12 human first mandibular molars were instrumented using the BioRace system until a size 25, .06 taper instrument. The mesial roots were filled with gutta-percha and AH-Plus using a vertical compaction technique. The specimens were scanned using microcomputed tomography with a voxel size of 16.8 μm before and after the retreatment procedures. To remove the filling material, the root canals were enlarged until the size 40, .04 taper instrument. The second step was to irrigate the root canals with xylene in the attempt to clean the root canals with paper points. In the third step, the passive ultrasonic irrigation technique (PUI) was performed using 2.5% sodium hypochlorite. The initial and residual filling material volume (mm(3) ) after each step was evaluated from the 0.5 to 6.5 mm level. The obtained data were expressed in terms of percentage of residual filling material. Statistical analysis was performed using the Friedman test (P < 0.05). All specimens had residual filling materials after all retreatment procedures. Passive ultrasonic irrigation enhanced the elimination of residual filling material in comparison with the mechanical stage at the 0.5-2.5 mm and 4.5-6.5 mm levels (P < 0.05). No significant difference was found between xylene and PUI methods. Filling materials were not completely removed by any of the retreatment procedures. The use of xylene and PUI after mechanical instrumentation enhanced removal of materials during endodontic retreatment of anatomically complex teeth. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.
30 CFR 250.456 - What safe practices must the drilling fluid program follow?
Code of Federal Regulations, 2012 CFR
2012-07-01
... circulate a volume of drilling fluid equal to the annular volume with the drill pipe just off-bottom. You... volume needed to fill the hole. Both sets of numbers must be posted near the driller's station. You must... industry-accepted practices and include density, viscosity, and gel strength; hydrogenion concentration...
30 CFR 250.456 - What safe practices must the drilling fluid program follow?
Code of Federal Regulations, 2014 CFR
2014-07-01
... circulate a volume of drilling fluid equal to the annular volume with the drill pipe just off-bottom. You... volume needed to fill the hole. Both sets of numbers must be posted near the driller's station. You must... industry-accepted practices and include density, viscosity, and gel strength; hydrogenion concentration...
30 CFR 250.456 - What safe practices must the drilling fluid program follow?
Code of Federal Regulations, 2013 CFR
2013-07-01
... circulate a volume of drilling fluid equal to the annular volume with the drill pipe just off-bottom. You... volume needed to fill the hole. Both sets of numbers must be posted near the driller's station. You must... industry-accepted practices and include density, viscosity, and gel strength; hydrogenion concentration...
30 CFR 250.1623 - Well-control fluids, equipment, and operations.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., (2) A well-control fluid-volume measuring device for determining fluid volumes when filling the hole on trips, and (3) A recording mud-pit-level indicator to determine mud-pit-volume gains and losses... the change in fluid level decreases the hydrostatic pressure 75 psi or every five stands of drill pipe...
Li, Qiang; Pu, Xiaoyun
2013-07-20
A method for measuring the refractive index (RI) of a small volume of liquid and a capillary wall is presented in this paper. A transparent capillary filled with liquid is used as a cylindrical positive lens; subsequently, the focal length of the lens is derived through the base of paraxial approximation, which is recorded as a function of the RIs of the liquid and capillary wall. With the RI of a capillary wall known, the RI of the liquid can be obtained by measuring the focal length of the lens, which is characterized by a microquantity liquid, spatial resolution, and easy operation. The RI of the capillary wall can be calculated without ruining the capillary if the capillary is filled with a standard liquid (RI is known), the deviation of which is less than 0.003 RIU. The factors affecting accuracy of the measurement, for instance, the depth of a field (DOF) in a reading microscope system and the outer and inner diameters of a capillary are analyzed, while illustrating that the effective DOF plays an essential role in accurate measurement.
Quantitative Characterization of Molecular Similarity Spaces: Tools for Computational Toxicology
2000-01-20
numbers for hydrogen-filled molecular structure, hydrogen-suppressed molecular structure, and van der Waals volume. Van der Waals...relative covalent radii Geometrical Vw van der Waals volume 3DW 3-D Wiener number for the hydrogen-suppressed geometric distance matrix...molecular structure, and van der Waals volume. Van der Waals volume, Vw (Bondi 1964). was calculated using Sybyl 6.1 from Tripos As- sociates. Inc
Bartesaghi, Davide; Pérez, Irene del Carmen; Kniepert, Juliane; Roland, Steffen; Turbiez, Mathieu; Neher, Dieter; Koster, L. Jan Anton
2015-01-01
Among the parameters that characterize a solar cell and define its power-conversion efficiency, the fill factor is the least well understood, making targeted improvements difficult. Here we quantify the competition between charge extraction and recombination by using a single parameter θ, and we demonstrate that this parameter is directly related to the fill factor of many different bulk-heterojunction solar cells. Our finding is supported by experimental measurements on 15 different donor:acceptor combinations, as well as by drift-diffusion simulations of organic solar cells in which charge-carrier mobilities, recombination rate, light intensity, energy levels and active-layer thickness are all varied over wide ranges to reproduce typical experimental conditions. The results unify the fill factors of several very different donor:acceptor combinations and give insight into why fill factors change so much with thickness, light intensity and materials properties. To achieve fill factors larger than 0.8 requires further improvements in charge transport while reducing recombination. PMID:25947637
Kim, Jae-Yup; Kang, Soon Hyung; Kim, Hyun Sik; Sung, Yung-Eun
2010-02-16
Highly ordered mesoporous Al(2)O(3)/TiO(2) was prepared by sol-gel reaction and evaporation-induced self-assembly (EISA) for use in dye-sensitized solar cells. The prepared materials had two-dimensional, hexagonal pore structures with anatase crystalline phases. The average pore size of mesoporous Al(2)O(3)/TiO(2) remained uniform and in the range of 6.33-6.58 nm while the Brunauer-Emmett-Teller (BET) surface area varied from 181 to 212 m(2)/g with increasing the content of Al(2)O(3). The incorporation of Al content retarded crystallite growth, thereby decreasing crystallite size while simultaneously improving the uniformity of pore size and volume. The thin Al(2)O(3) layer was located mostly on the mesopore surface, as confirmed by X-ray photoelectron spectroscopy (XPS). The Al(2)O(3) coating on the mesoporous TiO(2) film contributes to the essential energy barrier which blocks the charge recombination process in dye-sensitized solar cells. Mesoporous Al(2)O(3)/TiO(2) (1 mol % Al(2)O(3)) exhibited enhanced power conversion efficiency (V(oc) = 0.74 V, J(sc) = 15.31 mA/cm(2), fill factor = 57%, efficiency = 6.50%) compared to pure mesoporous TiO(2) (V(oc) = 0.72 V, J(sc) = 16.03 mA/cm(2), fill factor = 51%, efficiency = 5.88%). Therefore, the power conversion efficiency was improved by approximately 10.5%. In particular, the increase in V(oc) and fill factor resulted from the inhibition of charge recombination and the improvement of pore structure.
2017-01-31
AFRL-SA-WP-SR-2017-0004 Correlation Between Endotracheal Tube Cuff Pressure and Tracheal Wall Pressure Using Air- and Saline -Filled...Correlation Between Endotracheal Tube Cuff Pressure and Tracheal Wall Pressure Using Air- and Saline -Filled Cuffs 5a. CONTRACT NUMBER FA8650-14...descending from altitude. When using saline in the ETT cuff, TW pressure differences with the 7.5 high-volume, low-pressure cuff and 8.0 TaperGuard
Wognum, S; Heethuis, S E; Rosario, T; Hoogeman, M S; Bel, A
2014-07-01
The spatial accuracy of deformable image registration (DIR) is important in the implementation of image guided adaptive radiotherapy techniques for cancer in the pelvic region. Validation of algorithms is best performed on phantoms with fiducial markers undergoing controlled large deformations. Excised porcine bladders, exhibiting similar filling and voiding behavior as human bladders, provide such an environment. The aim of this study was to determine the spatial accuracy of different DIR algorithms on CT images of ex vivo porcine bladders with radiopaque fiducial markers applied to the outer surface, for a range of bladder volumes, using various accuracy metrics. Five excised porcine bladders with a grid of 30-40 radiopaque fiducial markers attached to the outer wall were suspended inside a water-filled phantom. The bladder was filled with a controlled amount of water with added contrast medium for a range of filling volumes (100-400 ml in steps of 50 ml) using a luer lock syringe, and CT scans were acquired at each filling volume. DIR was performed for each data set, with the 100 ml bladder as the reference image. Six intensity-based algorithms (optical flow or demons-based) implemented in theMATLAB platform DIRART, a b-spline algorithm implemented in the commercial software package VelocityAI, and a structure-based algorithm (Symmetric Thin Plate Spline Robust Point Matching) were validated, using adequate parameter settings according to values previously published. The resulting deformation vector field from each registration was applied to the contoured bladder structures and to the marker coordinates for spatial error calculation. The quality of the algorithms was assessed by comparing the different error metrics across the different algorithms, and by comparing the effect of deformation magnitude (bladder volume difference) per algorithm, using the Independent Samples Kruskal-Wallis test. The authors found good structure accuracy without dependency on bladder volume difference for all but one algorithm, and with the best result for the structure-based algorithm. Spatial accuracy as assessed from marker errors was disappointing for all algorithms, especially for large volume differences, implying that the deformations described by the registration did not represent anatomically correct deformations. The structure-based algorithm performed the best in terms of marker error for the large volume difference (100-400 ml). In general, for the small volume difference (100-150 ml) the algorithms performed relatively similarly. The structure-based algorithm exhibited the best balance in performance between small and large volume differences, and among the intensity-based algorithms, the algorithm implemented in VelocityAI exhibited the best balance. Validation of multiple DIR algorithms on a novel physiological bladder phantom revealed that the structure accuracy was good for most algorithms, but that the spatial accuracy as assessed from markers was low for all algorithms, especially for large deformations. Hence, many of the available algorithms exhibit sufficient accuracy for contour propagation purposes, but possibly not for accurate dose accumulation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stockstill, R.L.; George, J.F.
1996-09-01
Tests were conducted on two different 1:25-scale models of the New Bonneville Lock located on the Columbia River in Oregon. The lock models were built to study the filling and emptying systems, which consisted of designs utilizing bottom longitudinal floor culverts. The first design studied, defined as the H-H pattern system, consisted of four longitudinal flood culverts in each end of the lock chamber. The second system studied had two longitudinal floor culverts in each end of the lock chamber and was defined as the H pattern system. In the H-H pattern system, the filling culverts, which were located undermore » the lock chamber floor, connected to a crossover culvert with a horizontal splitter wall dividing the flow to upstream and downstream splitter manifolds were equal divisions led into four longitudinal flood culverts in each end of the lock chamber. With the type 6 (recommended) design and a 1-min valve opening time, the lock chamber filled in 8.7 min and emptied in 12.1 min. Due to differences in friction losses, the prototype can be expected to fill and empty about 20 percent faster than the model (7.0 min and 9.7 min, respectively). Modifications involving installing a slope in the lower sill and a v-notch design in the high sill were significant factors that resulted in fast filling and emptying times, low hawser forces, and only minor movement with various tow arrangements for different operating scenarios.« less
30 CFR 250.456 - What safe practices must the drilling fluid program follow?
Code of Federal Regulations, 2011 CFR
2011-07-01
... fluid. You must circulate a volume of drilling fluid equal to the annular volume with the drill pipe... fluid volume needed to fill the hole. Both sets of numbers must be posted near the driller's station... warrant. Your tests must conform to industry-accepted practices and include density, viscosity, and gel...
Bonow, R O; Ostrow, H G; Rosing, D R; Cannon, R O; Lipson, L C; Maron, B J; Kent, K M; Bacharach, S L; Green, M V
1983-11-01
To investigate the effects of verapamil on left ventricular systolic and diastolic function in patients with hypertrophic cardiomyopathy, we studied 14 patients at catheterization with a nonimaging scintillation probe before and after serial intravenous infusions of low-, medium-, and high-dose verapamil (total dose 0.17 to 0.72 mg/kg). Percent change in radionuclide stroke counts after verapamil correlated well with percent change in thermodilution stroke volume (r = .87), and changes in diastolic and systolic counts were used to assess relative changes in left ventricular volumes after verapamil. Verapamil produced dose-related increases in end-diastolic counts (19 +/- 9% increase; p less than .001), end-systolic counts (91 +/- 54% increase; p less than .001), and stroke counts (7 +/- 10% increase; p less than .02). This was associated with a decrease in ejection fraction (83 +/- 8% control, 73 +/- 10% verapamil; p less than .001) and, in the 10 patients with left ventricular outflow tract gradients, a reduction in gradient (62 +/- 27 mm Hg control, 32 +/- 35 mm Hg verapamil; p less than .01). The end-systolic pressure-volume relation was shifted downward and rightward in all patients, suggesting a negative inotropic effect. In 10 patients, left ventricular pressure-volume loops were constructed with simultaneous micromanometer pressure recordings and the radionuclide time-activity curve. In five patients, verapamil shifted the diastolic pressure-volume curve downward and rightward, demonstrating improved pressure-volume relations despite the negative inotropic effect, and also increased the peak rate of rapid diastolic filling. In the other five patients, the diastolic pressure-volume relation was unaltered by verapamil, and increased end-diastolic volumes occurred at higher end-diastolic pressures; in these patients, the peak rate of left ventricular diastolic filling was not changed by verapamil. The negative inotropic effects of intravenous verapamil are potentially beneficial in patients with hypertrophic cardiomyopathy by decreasing left ventricular contractile function and increasing left ventricular volume. Verapamil also enhances left ventricular diastolic filling and improves diastolic pressure-volume relations in some patients despite its negative inotropic effect.
46 CFR 38.15-1 - Filling of tanks-TB/ALL.
Code of Federal Regulations, 2011 CFR
2011-10-01
... that there is an outage of at least 2 percent of the volume of the tank at the temperature..., the maximum volume to which a tank may be loaded is: V L=0.98d r V/d L where: V L=maximum volume to which tank may be loaded. V=volume of tank. d r=density of cargo at the temperature required for a cargo...
Obese subjects show sex-specific differences in right ventricular hypertrophy.
Rider, Oliver J; Lewis, Andrew J M; Lewandowski, Adam J; Ntusi, Ntobeko; Nethononda, Richard; Petersen, Steffen E; Francis, Jane M; Pitcher, Alex; Banerjee, Rajarshi; Leeson, Paul; Neubauer, Stefan
2015-01-01
As right ventricular (RV) remodeling in obesity remains underinvestigated, and the impact of left ventricular (LV) diastolic dysfunction on RV hypertrophy is unknown, we aimed to investigate whether (1) sex-specific patterns of RV remodeling exist in obesity and (2) LV diastolic dysfunction in obesity is related to RV hypertrophy. Seven hundred thirty-nine subjects (women, n=345; men, n=394) without identifiable cardiovascular risk factors (body mass index [BMI], 15.3-59.2 kg/m2) underwent cardiovascular magnetic resonance (1.5 T) to measure RV mass (g), RV end-diastolic volume (mL), RV mass/volume ratio, and LV diastolic peak filling rate (mL/s). All subjects were normotensive (average, 119±11/73±8 mm Hg), normoglycaemic (4.8±0.5 mmol/L), and normocholesterolaemic (4.8±0.9 mmol/L) at the time of scanning. Across both sexes, there was a moderately strong positive correlation between BMI and RV mass (men, +0.8 g per BMI point increase; women, +1.0 g per BMI point increase; both P<0.001). Whereas women exhibited RV cavity dilatation (RV end-diastolic volume, +1.0 mL per BMI point increase; P<0.001), BMI was not correlated with RV end-diastolic volume in men (R=0.04; P=0.51). Concentric RV remodeling was present in both sexes, with RV mass/volume ratio being positively correlated to BMI (men, R=0.41; women, R=0.51; both P<0.001). Irrespective of sex, the LV peak filling rate was negatively correlated with both RV mass (men, R=-0.43; women, R=-0.44; both P<0.001) and RV mass/volume ratio (men, R=-0.37; women, R=-0.35; both P<0.001). A sex difference in RV remodeling exists in obesity. Whereas men exhibit concentric RV remodeling, women exhibit a mixed pattern of eccentric and concentric remodeling. Regardless of sex, reduced LV diastolic function is associated with concentric RV remodeling. © 2014 American Heart Association, Inc.
Baxa MicroMacrocompounder for parenteral nutrition solutions in a pediatric hospital.
Combeau, D; Rey, J B; Fontan, J E; Nouaille-Degorce, B; Brion, F
1999-01-01
The constant increase of parenteral nutrition (PN) manufacturing in our pediatric hospital led us to look for an automatic filling system. The aim of this study was to evaluate the MicroMacrocompounder (MM23) for compounding pediatric PN solutions. MM23 volumetric accuracy was tested with its different inlets (S, D, V) for volumes of sterile water for injection from 0.2 to 2900 mL. The influence of the solution viscosity and the source solution bottle replacements during the filling operation was also investigated. Manufacturing pediatric PN solutions was eventually assessed. Time to set up the system was 30 minutes. Maximum filling speeds with sterile water for injection were 860, 330, 154 mL/min for Vx, V and D inlets, respectively. Inlet S was not tested for MM23 filling speed. Minimal flush volume of 40 mL of sterile water for injection is necessary to clear the tube of residual ions. Average MM23 volumetric accuracy was < 5% for volumes > or = 0.5 mL for S and D inlets, and for volumes > or = 20 mL for V inlet. The volumetric accuracy was equal to 6.25% for 0.2 mL. In all experiments, volumetric accuracy was < 5%. The accuracy of electrolyte measurements performed on bag samples was less than 5% for 150 (74%) samples, between 5 and 10% for 27 (13%) samples and greater than 10% for 27 (13%) samples. Microbiological analysis showed no positive culture. The average manufacturing times were 56.8 +/- 4.5, 188.2 +/- 7.7 and 447.2 +/- 13.8 seconds for 130, 660 and 1800 mL bags, respectively. The MM23 compounder is suitable for compounding pediatric admixtures with source solutions volumes > or = 0.5 mL. This system has been used daily for five months in our department.
29 CFR 1910.111 - Storage and handling of anhydrous ammonia.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 1,200 gallons water capacity. (viii) Filling density. the percent ratio of the weight of the gas in... ammonia. (xi) Capacity. Total volume of the container in standard U.S. gallons. (xii) DOT specifications... allowable water level to which the container may be filled for test purposes. (vii) With the density of the...
29 CFR 1910.111 - Storage and handling of anhydrous ammonia.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 1,200 gallons water capacity. (viii) Filling density. the percent ratio of the weight of the gas in... ammonia. (xi) Capacity. Total volume of the container in standard U.S. gallons. (xii) DOT specifications... allowable water level to which the container may be filled for test purposes. (vii) With the density of the...
29 CFR 1910.111 - Storage and handling of anhydrous ammonia.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 1,200 gallons water capacity. (viii) Filling density. the percent ratio of the weight of the gas in... ammonia. (xi) Capacity. Total volume of the container in standard U.S. gallons. (xii) DOT specifications... allowable water level to which the container may be filled for test purposes. (vii) With the density of the...
DOT National Transportation Integrated Search
1995-04-01
A two year study was conducted as a continuation project for the Florida Department of Transportation (FDOT) to evaluate Municipal Waste Combustor (MWD) ash, Waste Glass, and Waste Tires for use as general highway fill. Initial studies conducted at F...
DOT National Transportation Integrated Search
1995-04-01
A two year study was conducted as a continuation project for the Florida Department of Transportation (FDOT) to evaluate Municipal Waste Combustor (MWC) ash, Waste Glass, and Waste Tires for use as general highway fill. Initial studies conducted at F...
Finite element modelling of creep cavity filling by solute diffusion
NASA Astrophysics Data System (ADS)
Versteylen, C. D.; Szymański, N. K.; Sluiter, M. H. F.; van Dijk, N. H.
2018-04-01
In recently discovered self healing creep steels, open-volume creep cavities are filled by the precipitation of supersaturated solute. These creep cavities form on the grain boundaries oriented perpendicular to the applied stress. The presence of a free surface triggers a flux of solute from the matrix, over the grain boundaries towards the creep cavities. We studied the creep cavity filling by finite element modelling and found that the filling time critically depends on (i) the ratio of diffusivities in the grain boundary and the bulk, and (ii) on the ratio of the intercavity distance and the cavity size. For a relatively large intercavity spacing 3D transport is observed when the grain boundary and volume diffusivities are of a similar order of magnitude, while a 2D behaviour is observed when the grain boundary diffusivity is dominant. Instead when the intercavity distance is small, the transport behaviour tends to a 1D behaviour in all cases, as the amount of solute available in the grain boundary is insufficient. A phase diagram with the transition lines is constructed.
Bladder filling variation during conformal radiotherapy for rectal cancer
NASA Astrophysics Data System (ADS)
Sithamparam, S.; Ahmad, R.; Sabarudin, A.; Othman, Z.; Ismail, M.
2017-05-01
Conformal radiotherapy for rectal cancer is associated with small bowel toxicity mainly diarrhea. Treating patients with a full bladder is one of the practical solutions to reduce small bowel toxicity. Previous studies on prostate and cervix cancer patients revealed that maintaining consistent bladder volume throughout radiotherapy treatment is challenging. The aim of this study was to measure bladder volume variation throughout radiotherapy treatment. This study also measured the association between bladder volume changes and diarrhea. Twenty two rectal cancer patients were recruited prospectively. Patients were planned for treatment with full bladder following departmental bladder filling protocol and the planning bladder volume was measured during CT-simulation. During radiotherapy, the bladder volume was measured weekly using cone-beam computed tomography (CBCT) and compared to planning bladder volume. Incidence and severity of diarrhea were recorded during the weekly patient review. There was a negative time trend for bladder volume throughout five weeks treatment. The mean bladder volume decreased 18 % from 123 mL (SD 54 mL) during CT-simulation to 101 mL (SD 71 mL) on the 5th week of radiotherapy, but the decrease is not statistically significant. However, there was a large variation of bladder volume within each patient during treatment. This study showed an association between changes of bladder volume and diarrhea (P = 0.045). In conclusion bladder volume reduced throughout radiotherapy treatment for conformal radiotherapy for rectal cancer and there was a large variation of bladder volume within patients.
A Model of Thermal Conductivity for Planetary Soils. 2; Theory for Cemented Soils
NASA Technical Reports Server (NTRS)
Piqueux, S.; Christensen, P. R.
2009-01-01
A numerical model of heat conduction through particulate media made of spherical grains cemented by various bonding agents is presented. The pore-filling gas conductivity, volume fraction, and thermal conductivity of the cementing phase are tunable parameters. Cement fractions <0.001-0.01% in volume have small effects on the soil bulk thermal conductivity. A significant conductivity increase (factor 3-8) is observed for bond fractions of 0.01 to 1% in volume. In the 1 to 15% bond fraction domain, the conductivity increases continuously but less intensely (25-100% conductivity increase compared to a 1% bond system). Beyond 15% of cements, the conductivity increases vigorously and the bulk conductivity rapidly approaches that of bedrock. The composition of the cements (i.e. conductivity) has little influence on the bulk thermal inertia of the soil, especially if the volume of bond <10%. These results indicate that temperature measurements are sufficient to detect cemented soils and quantify the amount of cementing phase, but the mineralogical nature of the bonds and the typical grain size are unlikely to be determined from orbit. On Mars, a widespread surface unit characterized by a medium albedo (0.19-0.26) and medium/high thermal inertia (200-600 J s(0.5)/sq m/K) has long been hypothesized to be associated with a duricrust. The fraction of cement required to fit the thermal data is less than approx.1-5% by volume. This small amount of material is consistent with orbital observations, confirming that soil cementation is an important factor controlling the thermal inertia of the Martian surface
A model of thermal conductivity for planetary soils: 2. Theory for cemented soils
NASA Astrophysics Data System (ADS)
Piqueux, S.; Christensen, P. R.
2009-09-01
A numerical model of heat conduction through particulate media made of spherical grains cemented by various bonding agents is presented. The pore-filling gas conductivity, volume fraction, and thermal conductivity of the cementing phase are tunable parameters. Cement fractions <0.001-0.01% in volume have small effects on the soil bulk thermal conductivity. A significant conductivity increase (factor 3-8) is observed for bond fractions of 0.01 to 1% in volume. In the 1 to 15% bond fraction domain, the conductivity increases continuously but less intensely (25-100% conductivity increase compared to a 1% bond system). Beyond 15% of cements, the conductivity increases vigorously and the bulk conductivity rapidly approaches that of bedrock. The composition of the cements (i.e. conductivity) has little influence on the bulk thermal inertia of the soil, especially if the volume of bond <10%. These results indicate that temperature measurements are sufficient to detect cemented soils and quantify the amount of cementing phase, but the mineralogical nature of the bonds and the typical grain size are unlikely to be determined from orbit. On Mars, a widespread surface unit characterized by a medium albedo (0.19-0.26) and medium/high thermal inertia (200-600 J s-0.5 m-2 K-1) has long been hypothesized to be associated with a duricrust. The fraction of cement required to fit the thermal data is less than ˜1-5% by volume. This small amount of material is consistent with orbital observations, confirming that soil cementation is an important factor controlling the thermal inertia of the Martian surface.
NASA Astrophysics Data System (ADS)
Phillips, Carolyn L.; Anderson, Joshua A.; Huber, Greg; Glotzer, Sharon C.
2012-05-01
We present filling as a type of spatial subdivision problem similar to covering and packing. Filling addresses the optimal placement of overlapping objects lying entirely inside an arbitrary shape so as to cover the most interior volume. In n-dimensional space, if the objects are polydisperse n-balls, we show that solutions correspond to sets of maximal n-balls. For polygons, we provide a heuristic for finding solutions of maximal disks. We consider the properties of ideal distributions of N disks as N→∞. We note an analogy with energy landscapes.
Yan, Han; Manion, Joseph G; Yuan, Mingjian; García de Arquer, F Pelayo; McKeown, George R; Beaupré, Serge; Leclerc, Mario; Sargent, Edward H; Seferos, Dwight S
2016-08-01
Intrinsic traps in organic semiconductors can be eliminated by trap-filling with F4-TCNQ. Photovoltaic tests show that devices with F4-TCNQ at parts per thousand concentration outperform control devices due to an improved fill factor. Further studies confirm the trap-filling pathway and demonstrate the general nature of this finding. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Küçükkaya Eren, Selen; Askerbeyli Örs, Sevinc; Yılmaz, Zeliha
2017-07-01
The purpose of this study was to evaluate the obturation quality of root canals filled with different techniques and to determine whether post space preparation had an effect on the quality of apical obturation using micro-computed tomographic (micro-CT) imaging. The root canals of 30 human mandibular premolar teeth were instrumented, and the specimens were divided into 3 groups according to the obturation technique used: cold lateral compaction (CLC), warm vertical compaction (WVC), or single-cone (SC) techniques. The specimens were stored at 37°C and 100% humidity for 1 week. Then, the coronal root filling material was removed in order to create a post space. Micro-CT scans were performed before and after post space preparation for the volumetric analysis of voids and filling materials. Data were analyzed using repeated-measures analysis of variance and Bonferroni tests. The CLC and SC groups showed a significantly greater percentage volume of voids than the WVC group (P < .05), whereas no significant difference was found between the CLC and SC groups before and after post space preparation (P > .05). The post space preparation caused a significant increase in the percentage volume of voids in the CLC and SC groups (P < .05). No significant difference was detected in the percentage volume of voids in the WVC group after post space preparation (P > .05). No root fillings were void free. The WVC group presented the best obturation quality. The post space preparation negatively influenced the apical integrity of the filling materials in the CLC and SC groups, whereas it had no significant effect in the WVC group. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Understanding uncertainty in seagrass injury recovery: an information-theoretic approach.
Uhrin, Amy V; Kenworthy, W Judson; Fonseca, Mark S
2011-06-01
Vessel groundings cause severe, persistent gaps in seagrass beds. Varying degrees of natural recovery have been observed for grounding injuries, limiting recovery prediction capabilities, and therefore, management's ability to focus restoration efforts where natural recovery is unlikely. To improve our capacity for predicting seagrass injury recovery, we used an information-theoretic approach to evaluate the relative contribution of specific injury attributes to the natural recovery of 30 seagrass groundings in Florida Keys National Marine Sanctuary, Florida, USA. Injury recovery was defined by three response variables examined independently: (1) initiation of seagrass colonization, (2) areal contraction, and (3) sediment in-filling. We used a global model and all possible subsets for four predictor variables: (1) injury age, (2) original injury volume, (3) original injury perimeter-to-area ratio, and (4) wave energy. Successional processes were underway for many injuries with fast-growing, opportunistic seagrass species contributing most to colonization. The majority of groundings that exhibited natural seagrass colonization also exhibited areal contraction and sediment in-filling. Injuries demonstrating colonization, contraction, and in-filling were on average older and smaller, and they had larger initial perimeter-to-area ratios. Wave energy was highest for colonizing injuries. The information-theoretic approach was unable to select a single "best" model for any response variable. For colonization and contraction, injury age had the highest relative importance as a predictor variable; wave energy appeared to be associated with second-order effects, such as sediment in-filling, which in turn, facilitated seagrass colonization. For sediment in-filling, volume and perimeter-to-area ratio had similar relative importance as predictor variables with age playing a lesser role than seen for colonization and contraction. Our findings confirm that these injuries naturally initiate seagrass colonization with the potential to recover to pre-injury conditions, but likely on a decadal scale given the slow growth of the climax species (Thalassia testudinum), which is often the most severely injured. Our analysis supports current perceptions that sediment in-filling is critical to the recovery process and indicates that in order to stabilize injuries and facilitate seagrass recovery, managers should consider immediate restorative filling procedures for injuries having an original volume >14-16 m3.
Torrent-Guasp, Francisco; Kocica, Mladen J; Corno, Antonio; Komeda, Masashi; Cox, James; Flotats, A; Ballester-Rodes, Manel; Carreras-Costa, Francesc
2004-03-01
The evidence of the ventricular myocardial band (VMB) has revealed unavoidable coherence and mutual coupling of form and function in the ventricular myocardium, making it possible to understand the principles governing electrical, mechanical and energetical events within the human heart. From the earliest Erasistratus' observations, principal mechanisms responsible for the ventricular filling have still remained obscured. Contemporary experimental and clinical investigations unequivocally support the attitude that only powerful suction force, developed by the normal ventricles, would be able to produce an efficient filling of the ventricular cavities. The true origin and the precise time frame for generating such force are still controversial. Elastic recoil and muscular contraction were the most commonly mentioned, but yet, still not clearly explained mechanisms involved in the ventricular suction. Classical concepts about timing of successive mechanical events during the cardiac cycle, also do not offer understandable insight into the mechanism of the ventricular filling. The net result is the current state of insufficient knowledge of systolic and particularly diastolic function of normal and diseased heart. Here we summarize experimental evidence and theoretical backgrounds, which could be useful in understanding the phenomenon of the ventricular filling. Anatomy of the VMB, and recent proofs for its segmental electrical and mechanical activation, undoubtedly indicates that ventricular filling is the consequence of an active muscular contraction. Contraction of the ascendent segment of the VMB, with simultaneous shortening and rectifying of its fibers, produces the paradoxical increase of the ventricular volume and lengthening of its long axis. Specific spatial arrangement of the ascendent segment fibers, their interaction with adjacent descendent segment fibers, elastic elements and intra-cavitary blood volume (hemoskeleton), explain the physical principles involved in this action. This contraction occurs during the last part of classical systole and the first part of diastole. Therefore, the most important part of ventricular diastole (i.e. the rapid filling phase), in which it receives >70% of the stroke volume, belongs to the active muscular contraction of the ascendent segment. We hope that these facts will give rise to new understanding of the principal mechanisms involved in normal and abnormal diastolic heart function.
Factors affecting volume calculation with single photon emission tomography (SPECT) method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, T.H.; Lee, K.H.; Chen, D.C.P.
1985-05-01
Several factors may influence the calculation of absolute volumes (VL) from SPECT images. The effect of these factors must be established to optimize the technique. The authors investigated the following on the VL calculations: % of background (BG) subtraction, reconstruction filters, sample activity, angular sampling and edge detection methods. Transaxial images of a liver-trunk phantom filled with Tc-99m from 1 to 3 ..mu..Ci/cc were obtained in 64x64 matrix with a Siemens Rota Camera and MDS computer. Different reconstruction filters including Hanning 20,32, 64 and Butterworth 20, 32 were used. Angular samplings were performed in 3 and 6 degree increments. ROI'smore » were drawn manually and with an automatic edge detection program around the image after BG subtraction. VL's were calculated by multiplying the number of pixels within the ROI by the slice thickness and the x- and y- calibrations of each pixel. One or 2 pixel per slice thickness was applied in the calculation. An inverse correlation was found between the calculated VL and the % of BG subtraction (r=0.99 for 1,2,3 ..mu..Ci/cc activity). Based on the authors' linear regression analysis, the correct liver VL was measured with about 53% BG subtraction. The reconstruction filters, slice thickness and angular sampling had only minor effects on the calculated phantom volumes. Detection of the ROI automatically by the computer was not as accurate as the manual method. The authors conclude that the % of BG subtraction appears to be the most important factor affecting the VL calculation. With good quality control and appropriate reconstruction factors, correct VL calculations can be achieved with SPECT.« less
Franzoso, Francesca D; Wohlmuth, Christoph; Greutmann, Matthias; Kellenberger, Christian J; Oxenius, Angela; Voser, Eva M; Valsangiacomo Buechel, Emanuela R
2016-09-01
The atria serve as reservoir, conduit, and active pump for ventricular filling. The performance of the atrial baffles after atrial switch repair for transposition of the great arteries may be abnormal and impact the function of the systemic right ventricle. We sought to assess atrial function in patients after atrial repair in comparison to patients after arterial switch repair (ASO) and to controls. Using magnetic resonance imaging, atrial volumes and functional parameters were measured in 17 patients after atrial switch repair, 9 patients after ASO and 10 healthy subjects. After the atrial switch operation, the maximum volume of the pulmonary venous atrium was significantly enlarged, but not of the systemic venous atrium. In both patients groups, independently from the surgical technique used, the minimum atrial volumes were elevated, which resulted in a decreased total empting fraction compared with controls (P < .01). The passive empting volume was diminished for right atrium, but elevated for left atrium after atrial switch and normal for left atrium after ASO; however, the passive empting fraction was diminished for both right atrium and left atrium after both operations (P < .01). The active empting volume was the most affected parameter in both atria and both groups and active empting fractions were highly significantly reduced compared with controls. Atrial function is abnormal in all patients, after atrial switch and ASO repair. The cyclic volume changes, that is, atrial filling and empting, are reduced when compared with normal subjects. Thus, the atria have lost part of their capacity to convert continuous venous flow into a pulsatile ventricular filling. The function of the pulmonary venous atrium, acting as preload for the systemic right ventricle, after atrial switch is altered the most. © 2015 Wiley Periodicals, Inc.
Evidence that the X-Ray Plasma in Microflares is in a Sequence of Subresolution Magnetic Tubes
NASA Technical Reports Server (NTRS)
Moore, Ronald L.; Falconer, D. A.; Porter, Jason G.
1998-01-01
We analyze the cooling of the X-ray emitting thermal plasma in microflares observed in active regions by the Yohkoh Soft X-ray Telescope. A typical microflare appears to be a transient brightening of an entire small magnetic loop, often having a diameter near the limit of resolution (approximately 2 x 10(exp 8) cm) (Shimizu 1995, PASJ, 47, 251). The X-ray plasma in the loop cools by emission of XUV radiation and by heat conduction to the cooler plasma at the feet of the loop. The cooling rate is determined by the plasma temperature and density and the loop length. The plasma density is determined from the observed X-ray brightness of the loop in combination with the temperature, the loop diameter, and the filling factor. The filling factor is the volume fraction of the loop occupied by the subset of magnetic tubes that is filled by the X-ray plasma and that contains practically all of the X-ray plasma present in the microflare loop. Taking typical values from the hundreds of microflares measured by Shimizu (1995) (X-ray brightness through the thin aluminum filter approximately 4 x 10(exp 3) DN/s/pixel, lifetime approximately 5 min, temperature approximately 6 x 10(exp 6) K, loop length approximately 10(exp 9) cm, loop diameter approximately 3 x 10(exp 8) cm), we find that for filling factors greater than approximately 1% (1) the cooling time is much shorter than the duration of the microflare, and (2) conductive cooling strongly dominates over radiative cooling. Because the cooling time is so short and because the conductive heat flux goes mainly into increasing the plasma density via chromospheric evaporation, we are compelled to conclude that (1) heating to X-ray temperatures continues through nearly the entire life of a microflare, (2) the heating keeps changing to different field lines, so that any one magnetic tube in the sequence of heated tubes emits X-rays only briefly in the life of the microflare, and (3) at any instant during the microflare the tubes filled with X-ray plasma occupy only a small fraction (less than approximately 10%) of the microflare loop. Hence, we expect that coronal X-ray images with spatial resolution 2-3 times better than from Yohkoh will show plenty of rapidly changing filamentary substructure in microflares.
Effect of bladder filling on doses to prostate and organs at risk: a treatment planning study
Liu, Mitchell; Kristensen, Sarah; Gelowitz, Gerald; Berthelet, Eric
2007-01-01
In the present study, we aimed to evaluate effects of bladder filling on dose–volume distributions for bladder, rectum, planning target volume (PTV), and prostate in radiation therapy of prostate cancer. Patients (n=21) were scanned with a full bladder, and after 1 hour, having been allowed to void, with an empty bladder. Radiotherapy plans were generated using a four‐field box technique and dose of 70 Gy in 35 fractions. First, plans obtained for full‐ and empty‐bladder scans were compared. Second, situations in which a patient was planned on full bladder but was treated on empty bladder, and vice versa, were simulated, assuming that patients were aligned to external tattoos. Doses to the prostate [equivalent uniform dose (EUD)], bladder and rectum [effective dose (Deff)], and normal tissue complication probability (NTCP) were compared. Dose to the small bowel was examined. Mean bladder volume was 354.3 cm3 when full and 118.2 cm3 when empty. Median prostate EUD was 70 Gy for plans based on full‐ and empty‐bladder scans alike. The median rectal Deff was 55.6 Gy for full‐bladder anatomy and 56.8 Gy for empty‐bladder anatomy, and the corresponding bladder Deff was 29.0 Gy and 49.3 Gy respectively. In 1 patient, part of the small bowel (7.5 cm3) received more than 50 Gy with full‐bladder anatomy, and in 6 patients, part (2.5 cm3−30 cm3) received more than 50 Gy with empty‐bladder anatomy. Bladder filling had no significant impact on prostate EUD or rectal Deff. A minimal volume of the small bowel received more than 50 Gy in both groups, which is below dose tolerance. The bladder Deff was higher with empty‐bladder anatomy; however, the predicted complication rates were clinically insignificant. When the multileaf collimator pattern was applied in reverse, substantial underdosing of the planning target volume (PTV) was observed, particularly for patients with prostate shifts in excess of 0.5 cm in any one direction. However, the prostate shifts showed no correlation with bladder filling, and therefore the PTV underdosing also cannot be related to bladder filling. For some patients, bladder dose–volume constraints were not fulfilled in the worst‐case scenario—that is, when a patient planned with full bladder consistently arrived for treatment with an empty bladder. PACS numbers: 87.53.‐j, 87.53.Kn, 87.53.Tf PMID:17592448
Mathematical modeling of the process of filling a mold during injection molding of ceramic products
NASA Astrophysics Data System (ADS)
Kulkov, S. N.; Korobenkov, M. V.; Bragin, N. A.
2015-10-01
Using the software package Fluent it have been predicted of the filling of a mold in injection molding of ceramic products is of great importance, because the strength of the final product is directly related to the presence of voids in the molding, making possible early prediction of inaccuracies in the mold prior to manufacturing. The calculations were performed in the formulation of mathematical modeling of hydrodynamic turbulent process of filling a predetermined volume of a viscous liquid. The model used to determine the filling forms evaluated the influence of density and viscosity of the feedstock, and the injection pressure on the mold filling process to predict the formation of voids in the area caused by the shape defect geometry.
ERIC Educational Resources Information Center
Hughes, Stephen W.
2005-01-01
A little-known method of measuring the volume of small objects based on Archimedes' principle is described, which involves suspending an object in a water-filled container placed on electronic scales. The suspension technique is a variation on the hydrostatic weighing technique used for measuring volume. The suspension method was compared with two…
30 CFR 250.614 - Well-control fluids, equipment, and operations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... well is shut in and secured. (b) When coming out of the hole with drill pipe or a workover string, the... string and drill collars that may be pulled prior to filling the hole and the equivalent well-control... fluid volumes when filling the hole on trips; and (3) A recording mud-pit-level indicator to determine...
Alternative Fuels Data Center: Filling CNG Fuel Tanks
, therefore containing less energy by volume when the fuel system reaches the rated pressure. For this reason because when gas molecules are compressed, they create heat. The faster they are compressed, the more they heat up and expand. So when the gas is compressed rapidly through a fast-fill process, the molecules
DOT National Transportation Integrated Search
1995-04-01
A two year study was conducted as a continuation project for the Florida Department of Transportation (FDOT) to evlauate Municipal Waste Combustor (MWC) ash, Waste Glass, and Waste Tires for use as general highway fill. Initial studies conducted at F...
Local and synoptic controls on rapid supraglacial lake drainage in West Greenland
NASA Astrophysics Data System (ADS)
Williamson, Andrew; Banwell, Alison; Arnold, Neil; Willis, Ian
2016-04-01
Many supraglacial lakes within the ablation zone of the Greenland Ice Sheet (GrIS) are known to drain rapidly (in <1 day) in the mid- to late melt season, delivering large meltwater pulses to the subglacial drainage system, thus affecting basal water pressures and ice-sheet dynamics. Although it is now generally recognised that rapid lake drainage is caused by hydrofracture, the precise controls on hydrofracture initiation remain poorly understood: they may be linked to a local critical water-volume threshold, or they may be associated with synoptic-scale factors, such as ice thickness, driving stresses, ice velocities and strain rates. A combination of the local water-volume threshold and one or more synoptic-scale factors may explain the overall patterns of rapid lake drainage, but this requires verification using targeted field- and remotely-based studies that cover large areas of the GrIS and span long timescales. Here, we investigate a range of potential controls on rapid supraglacial lake drainage in the land-terminating Paakitsoq region of the ice sheet, northeast of Jakobshavn Isbræ, for the 2014 melt season. We have analysed daily 250-m Moderate Resolution Imaging Spectroradiometer (MODIS) imagery in order to calculate lake areas, depths and volumes, and have developed an automatic lake-tracking algorithm to determine the dates on which all rapid lake drainage events occur. For each rapidly draining lake, the water volumes immediately prior to drainage are compared with other local factors, notably lake-filling rate and ice thickness, and with a variety of synoptic-scale features, such as slope angles, driving stresses, surface velocities, surface strain rates and the incidence of nearby lake-drainage events. We present the outcomes of our statistical analysis to elicit the statistically significant controls on hydrofracture beneath supraglacial lakes.
Reliability of cystometrically obtained intravesical pressures in patients with neurogenic bladders.
Hess, Marika J; Lim, Lance; Yalla, Subbarao V
2002-01-01
Urodynamic studies in patients with neurogenic bladder detect and categorize neurourodynamic states, identify the risk for urologic sequelae, and determine the necessity for interventions. Because urodynamic studies serves as a prognostic indicator and guides patient management, pressure measurements during the study must accurately represent bladder function under physiologic conditions. Because nonphysiologic bladder filling used during conventional urodynamic studies may alter the bladder's accommodative properties, we studied how closely the intravesical pressures obtained before filling cystometry resembled those obtained during the filling phase of the cystometrogram. Twenty-two patients (21 men, 1 woman) with neurogenic bladders underwent standard urodynamic studies. A 16F triple-lumen catheter was inserted into the bladder, and the intravesical pressures were recorded (physiologic volume-specific pressures, PVSP). After emptying the bladder, an equal volume of normal saline solution was reinfused, and the pressures were recorded again (cystometric volume-specific pressure, CVSP). All patients underwent routine fluoroscopically assisted urodynamic testing. The PVSP and the CVSP were compared using the Wilcoxon signed ranks test. P value of .05 was significant. The mean PVSP was 14.5 cmH2O (range, 4-42 cmH2O) and mean CVSP was 20.6 cmH2O (range, 6-70 cmH2O). The CVSP was significantly higher than the PVSP (P = .01). Filling pressures during cystometry (CVSP) were significantly higher than the pressures measured at rest (PVSP). This study also suggests a strong correlation between PVSP and CVSP.
NASA Astrophysics Data System (ADS)
McHugh, C. M.; Pekar, S. F.; Ryan, W. B.; Carbotte, S.; Bell, R.; Burckle, L.
2002-12-01
Estuaries are widely preserved in the geologic record and the estuarine fill, contained between non-marine sediment, provides an excellent temporal marker for continental margin studies. Estuarine stratigraphic models have provided a framework within which to interpret the estuarine fill. However, estuarine systems differ greatly in the shape of their valleys, the tectonic boundaries they cross, and in sediment supply so that their position in the geologic record may be out of sequence with that predicted by the models. New insights into estuarine systems and models are provided by the Hudson River Estuary (HRE; New York State) based on >150 cores and grab sediment samples and acoustic images documenting in great detail how the HRE filled its earlier excavated valley during the latest Holocene (3ka to present). Radiocarbon and 137-Cs radioisotope ages, borehole, and core data document the sedimentation patterns of the estuary. Diatom assemblages provide estimates of the shallowing-upwards of the estuary as its basin filled with sediments. The three areas of the stratigraphic model present in the HRE, include zones formed within inner fluvial and outer marine areas, (containing coarse-grained, sands and gravels), and a central area (containing fine-grained, silts and clays), that are nearly filled with little room for sediments to accumulate at or near sea-level. This has resulted in sedimentary bypass for almost the entire length the estuary. South of Kingston, fine-grained sediments have ceased accumulating when the bottom approaches wave base. Upstream from Kingston, final filling occurs as sediments fill in the remaining accommodation, forming islands. This should result in the export of sediment to the coastal zone. Instead, localized areas of sediment trapping still exist, which are related to the Hudson Valley Highlands and to the location of the estuarine turbidity maximum that hold large volumes of sediment. As a result minor volumes of Recent sediment are accumulating in coastal bays (Sandy Hook, New Jersey) and on the inner shelf, and sediment export to the Hudson Shelf Valley on the mid-shelf is nearly non-existent, with sediments dated at 14ka from 14-C on the outer shelf. Additionally, anthropogenic activities (construction of bridges and dredging) alter sedimentation patterns in the estuary leading to continued localized erosion and deposition. For example, sediment export onto the shelf is taking place, not by natural processes but by dredging. The variability documented for the HRE indicates that although estuarine and stratigraphic models provide a framework for continental margin studies, the models need to be interpreted, taking into consideration these factors.
Development of High-Fill-Factor Large-Aperture Micromirrors for Agile Optical Phased Arrays
2010-02-28
Final Project Report Contract/Grant Title: Development of High-Fill-Factor Large-Aperture Micromirrors for Agile Optical Phased Arrays...factor (HFF) micromirror array (MMA) has been proposed, fabricated and tested. Optical-phased-array (OPA) beam steering based on the HFF MMA has also...electrically tuned to multiple 2. 1. Background High-fill-factor (HFF) micromirror arrays (MMAs) can form optical phased arrays (OPAs) for laser beam
Marui, Akira; Saji, Yoshiaki; Nishina, Takeshi; Tadamura, Eiji; Kanao, Shotaro; Shimamoto, Takeshi; Sasahashi, Nozomu; Ikeda, Tadashi; Komeda, Masashi
2008-06-01
Left atrial geometry and mechanical functions exert a profound effect on left ventricular filling and overall cardiovascular performance. We sought to investigate the perioperative factors that influence left atrial geometry and mechanical functions after the Maze procedure in patients with refractory atrial fibrillation and left atrial enlargement. Seventy-four patients with atrial fibrillation and left atrial enlargement (diameter > or = 60 mm) underwent the Maze procedure in association with mitral valve surgery. The maximum left atrial volume and left atrial mechanical functions (booster pump, reservoir, and conduit function [%]) were calculated from the left atrial volume-cardiac cycle curves obtained by magnetic resonance imaging. A stepwise multiple regression analysis was performed to determine the independent variables that influenced the postoperative left atrial geometry and function. The multivariate analysis showed that left atrial reduction surgery concomitant with the Maze procedure and the postoperative maintenance of sinus rhythm were predominant independent variables for postoperative left atrial geometry and mechanical functions. Among the 58 patients who recovered sinus rhythm, the postoperative left atrial geometry and function were compared between patients with (VR group) and without (control group) left atrial volume reduction. At a mean follow-up period of 13.8 months, sinus rhythm recovery rate was better (85% vs 68%, P < .05) in the VR group and maximum left atrial volume was less (116 +/- 25 mL vs 287 +/- 73 mL, P < .001) than in the control group. The maximum left atrial volume reduced with time only in the VR group (reverse remodeling). Postoperative booster pump and reservoir function in the VR group were better than in the control group (25% +/- 6% vs 11% +/- 4% and 34% +/- 7% vs 16% +/- 4%, respectively, P < .001), whereas the conduit function in the VR group was lower than in the control group, indicating that the improvement of the booster pump and reservoir function compensated for the conduit function to left ventricular filling. Left atrial reduction concomitant with the Maze procedure helped restore both contraction (booster pump) and compliance (reservoir) of the left atrium and facilitated left atrial reverse remolding. Left atrial volume reduction and postoperative maintenance of sinus rhythm may be desirable in patients with refractory AF and left atrial enlargement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wognum, S., E-mail: s.wognum@gmail.com; Heethuis, S. E.; Bel, A.
2014-07-15
Purpose: The spatial accuracy of deformable image registration (DIR) is important in the implementation of image guided adaptive radiotherapy techniques for cancer in the pelvic region. Validation of algorithms is best performed on phantoms with fiducial markers undergoing controlled large deformations. Excised porcine bladders, exhibiting similar filling and voiding behavior as human bladders, provide such an environment. The aim of this study was to determine the spatial accuracy of different DIR algorithms on CT images ofex vivo porcine bladders with radiopaque fiducial markers applied to the outer surface, for a range of bladder volumes, using various accuracy metrics. Methods: Fivemore » excised porcine bladders with a grid of 30–40 radiopaque fiducial markers attached to the outer wall were suspended inside a water-filled phantom. The bladder was filled with a controlled amount of water with added contrast medium for a range of filling volumes (100–400 ml in steps of 50 ml) using a luer lock syringe, and CT scans were acquired at each filling volume. DIR was performed for each data set, with the 100 ml bladder as the reference image. Six intensity-based algorithms (optical flow or demons-based) implemented in theMATLAB platform DIRART, a b-spline algorithm implemented in the commercial software package VelocityAI, and a structure-based algorithm (Symmetric Thin Plate Spline Robust Point Matching) were validated, using adequate parameter settings according to values previously published. The resulting deformation vector field from each registration was applied to the contoured bladder structures and to the marker coordinates for spatial error calculation. The quality of the algorithms was assessed by comparing the different error metrics across the different algorithms, and by comparing the effect of deformation magnitude (bladder volume difference) per algorithm, using the Independent Samples Kruskal-Wallis test. Results: The authors found good structure accuracy without dependency on bladder volume difference for all but one algorithm, and with the best result for the structure-based algorithm. Spatial accuracy as assessed from marker errors was disappointing for all algorithms, especially for large volume differences, implying that the deformations described by the registration did not represent anatomically correct deformations. The structure-based algorithm performed the best in terms of marker error for the large volume difference (100–400 ml). In general, for the small volume difference (100–150 ml) the algorithms performed relatively similarly. The structure-based algorithm exhibited the best balance in performance between small and large volume differences, and among the intensity-based algorithms, the algorithm implemented in VelocityAI exhibited the best balance. Conclusions: Validation of multiple DIR algorithms on a novel physiological bladder phantom revealed that the structure accuracy was good for most algorithms, but that the spatial accuracy as assessed from markers was low for all algorithms, especially for large deformations. Hence, many of the available algorithms exhibit sufficient accuracy for contour propagation purposes, but possibly not for accurate dose accumulation.« less
A voxel-based technique to estimate the volume of trees from terrestrial laser scanner data
NASA Astrophysics Data System (ADS)
Bienert, A.; Hess, C.; Maas, H.-G.; von Oheimb, G.
2014-06-01
The precise determination of the volume of standing trees is very important for ecological and economical considerations in forestry. If terrestrial laser scanner data are available, a simple approach for volume determination is given by allocating points into a voxel structure and subsequently counting the filled voxels. Generally, this method will overestimate the volume. The paper presents an improved algorithm to estimate the wood volume of trees using a voxel-based method which will correct for the overestimation. After voxel space transformation, each voxel which contains points is reduced to the volume of its surrounding bounding box. In a next step, occluded (inner stem) voxels are identified by a neighbourhood analysis sweeping in the X and Y direction of each filled voxel. Finally, the wood volume of the tree is composed by the sum of the bounding box volumes of the outer voxels and the volume of all occluded inner voxels. Scan data sets from several young Norway maple trees (Acer platanoides) were used to analyse the algorithm. Therefore, the scanned trees as well as their representing point clouds were separated in different components (stem, branches) to make a meaningful comparison. Two reference measurements were performed for validation: A direct wood volume measurement by placing the tree components into a water tank, and a frustum calculation of small trunk segments by measuring the radii along the trunk. Overall, the results show slightly underestimated volumes (-0.3% for a probe of 13 trees) with a RMSE of 11.6% for the individual tree volume calculated with the new approach.
Alexander, Siobhan E; Arlen, Angela M; Storm, Douglas W; Kieran, Kathleen; Cooper, Christopher S
2015-04-01
Improved identification of children with vesicoureteral reflux at risk for recurrent febrile urinary tract infection may impact management decisions. We hypothesized that reflux occurring earlier during bladder filling increases the duration of exposure of the kidneys to bacteria, and, therefore, increases the risk of pyelonephritis. Children with vesicoureteral reflux and detailed voiding cystourethrogram data were identified. Bladder volume at onset of reflux was normalized for age. Demographics, reflux grade, laterality, presence/absence of bladder-bowel dysfunction and breakthrough febrile urinary tract infections were assessed. Median followup was 24 months (IQR 12 to 52). A total of 208 girls and 47 boys were analyzed with a mean ± SD age at diagnosis of 3.1 ± 2.6 years. On univariate analysis history of febrile urinary tract infection (HR 2.17, 95% CI 1.33-2.85, p = 0.01), dilating vesicoureteral reflux (HR 1.6, 95% CI 1.05-2.42, p = 0.03) and bladder-bowel dysfunction (HR 1.66, 95% CI 0.99-2.75, p = 0.05) were associated with an increased risk of breakthrough febrile urinary tract infection. Median bladder volume at onset of reflux in children with breakthrough febrile urinary tract infection was significantly less (33.1%) than in those without infection (49.5%, p = 0.003). Reflux onset at 35% predicted bladder capacity or less was associated with a significantly increased risk of breakthrough febrile urinary tract infection on multivariate analysis (HR 1.58, 95% CI 1.05-2.38, p = 0.03). Children with early filling vesicoureteral reflux are at increased risk for breakthrough febrile urinary tract infection independent of reflux grade. Bladder volume at onset of reflux should be recorded during cystograms since it provides additional prognostic information about the risk of pyelonephritis and resolution, and may assist with counseling and clinical decision making. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Stolle, Achim; Schmidt, Robert; Jacob, Katharina
2014-01-01
The scale-up of the Knoevenagel-condensation between vanillin and barbituric acid carried out in planetary ball mills is investigated from an engineering perspective. Generally, the reaction proceeded in the solid state without intermediate melting and afforded selectively only one product. The reaction has been used as a model to analyze the influence and relationship of different parameters related to operation in planetary ball mills. From the viewpoint of technological parameters the milling ball diameter, dMB, the filling degree with respect to the milling balls' packing, ΦMB,packing, and the filling degree of the substrates with respect to the void volume of the milling balls' packing, ΦGS, have been investigated at different reaction scales. It was found that milling balls with small dMB lead to higher yields within shorter reaction time, treaction, or lower rotation frequency, rpm. Thus, the lower limit is set considering the technology which is available for the separation of the milling balls from the product after the reaction. Regarding ΦMB,packing, results indicate that the optimal value is roughly 50% of the total milling beakers' volume, VB,total, independent of the reaction scale or reaction conditions. Thus, 30% of VB,total are taken by the milling balls. Increase of the initial batch sizes changes ΦGS significantly. However, within the investigated parameter range no negative influence on the yield was observed. Up to 50% of VB,total can be taken over by the substrates in addition to 30% for the total milling ball volume. Scale-up factors of 15 and 11 were realized considering the amount of substrates and the reactor volume, respectively. Beside technological parameters, variables which influence the process itself, treaction and rpm, were investigated also. Variation of those allowed to fine-tune the reaction conditions in order to maximize the yield and minimize the energy intensity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This volume contains the interim change notice for physical testing. Covered are: properties of solutions, slurries, and sludges; rheological measurement with cone/plate viscometer; % solids determination; particle size distribution by laser scanning; penetration resistance of radioactive waste; operation of differential scanning calorimeter, thermogravimetric analyzer, and high temperature DTA and DSC; sodium rod for sodium bonded fuel; filling SP-100 fuel capsules; sodium filling of BEATRIX-II type capsules; removal of alkali metals with ammonia; specific gravity of highly radioactive solutions; bulk density of radioactive granular solids; purification of Li by hot gettering/filtration; and Li filling of MOTA capsules.
NASA Astrophysics Data System (ADS)
Linnenberger, A.
2018-02-01
Wavefront shaping devices such as deformable mirrors, liquid crystal spatial light modulators (SLMs), and active lenses are of considerable interest in microscopy for aberration correction, volumetric imaging, and programmable excitation. Liquid crystal SLMs are high resolution phase modulators capable of creating complex phase profiles to reshape, or redirect light within a three-dimensional (3D) volume. Recent advances in Meadowlark Optics (MLO) SLMs reduce losses by increasing fill factor from 83.4% to 96%, and improving resolution from 512 x 512 pixels to 1920 x 1152 pixels while maintaining a liquid crystal response time of 300 Hz at 1064 nm. This paper summarizes new SLM capabilities, and benefits for microscopy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bissa, Shivangi; Naruka, Preeti; Bishnoi, Nidhi
In the present study the dielectric optical response of various nanostructures of ZnO deposited on silica substrate has been studied using Maxwell-Garnett Effective Medium Theory. Using the volume filling factors for different nanostructures of ZnO the effective dielectric constant has been evaluated. The variation of this effective dielectric constant with the frequency of applied signal has been investigated. Moreover, the reflectance of the film, power absorption and variation of refractive index with frequency has been studied. The results obtained show that the quantum confinement effects in ZnO nano-structural films deposited on silica substrate give rise to distinct optical properties makingmore » it an ideal choice for high power THz generation.« less
30 CFR 780.35 - Disposal of excess spoil.
Code of Federal Regulations, 2011 CFR
2011-07-01
... the operation has been designed to minimize, to the extent possible, the volume of excess spoil that... authority, that the designed maximum cumulative volume of all proposed excess spoil fills within the permit... and related environmental values. You must design the operation to avoid placement of excess spoil in...
30 CFR 784.19 - Disposal of excess spoil.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the operation has been designed to minimize, to the extent possible, the volume of excess spoil that... authority, that the designed maximum cumulative volume of all proposed excess spoil fills within the permit... and related environmental values. You must design the operation to avoid placement of excess spoil in...
30 CFR 780.35 - Disposal of excess spoil.
Code of Federal Regulations, 2014 CFR
2014-07-01
... the operation has been designed to minimize, to the extent possible, the volume of excess spoil that... authority, that the designed maximum cumulative volume of all proposed excess spoil fills within the permit... and related environmental values. You must design the operation to avoid placement of excess spoil in...
30 CFR 780.35 - Disposal of excess spoil.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the operation has been designed to minimize, to the extent possible, the volume of excess spoil that... authority, that the designed maximum cumulative volume of all proposed excess spoil fills within the permit... and related environmental values. You must design the operation to avoid placement of excess spoil in...
30 CFR 784.19 - Disposal of excess spoil.
Code of Federal Regulations, 2011 CFR
2011-07-01
... the operation has been designed to minimize, to the extent possible, the volume of excess spoil that... authority, that the designed maximum cumulative volume of all proposed excess spoil fills within the permit... and related environmental values. You must design the operation to avoid placement of excess spoil in...
30 CFR 784.19 - Disposal of excess spoil.
Code of Federal Regulations, 2014 CFR
2014-07-01
... the operation has been designed to minimize, to the extent possible, the volume of excess spoil that... authority, that the designed maximum cumulative volume of all proposed excess spoil fills within the permit... and related environmental values. You must design the operation to avoid placement of excess spoil in...
30 CFR 784.19 - Disposal of excess spoil.
Code of Federal Regulations, 2013 CFR
2013-07-01
... the operation has been designed to minimize, to the extent possible, the volume of excess spoil that... authority, that the designed maximum cumulative volume of all proposed excess spoil fills within the permit... and related environmental values. You must design the operation to avoid placement of excess spoil in...
30 CFR 780.35 - Disposal of excess spoil.
Code of Federal Regulations, 2012 CFR
2012-07-01
... the operation has been designed to minimize, to the extent possible, the volume of excess spoil that... authority, that the designed maximum cumulative volume of all proposed excess spoil fills within the permit... and related environmental values. You must design the operation to avoid placement of excess spoil in...
30 CFR 780.35 - Disposal of excess spoil.
Code of Federal Regulations, 2013 CFR
2013-07-01
... the operation has been designed to minimize, to the extent possible, the volume of excess spoil that... authority, that the designed maximum cumulative volume of all proposed excess spoil fills within the permit... and related environmental values. You must design the operation to avoid placement of excess spoil in...
30 CFR 784.19 - Disposal of excess spoil.
Code of Federal Regulations, 2012 CFR
2012-07-01
... the operation has been designed to minimize, to the extent possible, the volume of excess spoil that... authority, that the designed maximum cumulative volume of all proposed excess spoil fills within the permit... and related environmental values. You must design the operation to avoid placement of excess spoil in...
NASA Astrophysics Data System (ADS)
Lin, Zhi; Zhang, Qinghai
2017-09-01
We propose high-order finite-volume schemes for numerically solving the steady-state advection-diffusion equation with nonlinear Robin boundary conditions. Although the original motivation comes from a mathematical model of blood clotting, the nonlinear boundary conditions may also apply to other scientific problems. The main contribution of this work is a generic algorithm for generating third-order, fourth-order, and even higher-order explicit ghost-filling formulas to enforce nonlinear Robin boundary conditions in multiple dimensions. Under the framework of finite volume methods, this appears to be the first algorithm of its kind. Numerical experiments on boundary value problems show that the proposed fourth-order formula can be much more accurate and efficient than a simple second-order formula. Furthermore, the proposed ghost-filling formulas may also be useful for solving other partial differential equations.
Gravitational independence of single-breath washout tests in recumbent dogs
NASA Technical Reports Server (NTRS)
Tomioka, Shinichi; Kubo, Susumu; Guy, Harold J. B.; Prisk, G. K.
1988-01-01
The effect of gravitational orientation in the mechanism of lung filling and emptying in dogs was examined by conducting simultaneously Ar-bolus and N2 single-breath washout tests (SBWTs) in 10 anesthetized dogs (prone and supine), with three of the dogs subjected to body rotation. Transpulmonary pressure was measured simultaneously, allowing identification of the lung volume above residual volume at which there was an inflection point in the pressure-volume curve. Combined resident gas and bolus SBWTs in recumbent dogs were found to be different from such tests in humans; in dogs, the regional distribution of ventilation was not primarily determined by gravity. The measurements did not make it possible to discern exact mechanisms of filling and emptying, but both processes appear to be related to lung, thorax, and mediastinum interactions and/or differences in regional mechanical properties of the lungs.
Influence of fundamental mode fill factor on disk laser output power and laser beam quality
NASA Astrophysics Data System (ADS)
Cheng, Zhiyong; Yang, Zhuo; Shao, Xichun; Li, Wei; Zhu, Mengzhen
2017-11-01
An three-dimensional numerical model based on finite element method and Fox-Li method with angular spectrum diffraction theoy is developed to calculate the output power and power density distribution of Yb:YAG disk laser. We invest the influence of fundamental mode fill factor(the ratio of fundamental mode size and pump spot size) on the output power and laser beam quality. Due to aspherical aberration and soft aperture effect in laser disk, high beam quality can be achieve with relative lower efficiency. The highest output power of fundamental laser mode is influenced by the fundamental mode fill factor. Besides we find that optimal mode fill factor increase with pump spot size.
NASA Astrophysics Data System (ADS)
Kaienburg, Pascal; Rau, Uwe; Kirchartz, Thomas
2016-08-01
Understanding the fill factor in organic solar cells remains challenging due to its complex dependence on a multitude of parameters. By means of drift-diffusion simulations, we thoroughly analyze the fill factor of such low-mobility systems and demonstrate its dependence on a collection coefficient defined in this work. We systematically discuss the effect of different recombination mechanisms, space-charge regions, and contact properties. Based on these findings, we are able to interpret the thickness dependence of the fill factor for different experimental studies from the literature. The presented model provides a facile method to extract the photoactive layer's electronic quality which is of particular importance for the fill factor. We illustrate that over the past 15 years, the electronic quality has not been continuously improved, although organic solar-cell efficiencies increased steadily over the same period of time. Only recent reports show the synthesis of polymers for semiconducting films of high electronic quality that are able to produce new efficiency records.
Ragagnin, Marilia Nagata; Gorman, Daniel; McCarthy, Ian Donald; Sant'Anna, Bruno Sampaio; de Castro, Cláudio Campi; Turra, Alexander
2018-01-11
Obtaining accurate and reproducible estimates of internal shell volume is a vital requirement for studies into the ecology of a range of shell-occupying organisms, including hermit crabs. Shell internal volume is usually estimated by filling the shell cavity with water or sand, however, there has been no systematic assessment of the reliability of these methods and moreover no comparison with modern alternatives, e.g., computed tomography (CT). This study undertakes the first assessment of the measurement reproducibility of three contrasting approaches across a spectrum of shell architectures and sizes. While our results suggested a certain level of variability inherent for all methods, we conclude that a single measure using sand/water is likely to be sufficient for the majority of studies. However, care must be taken as precision may decline with increasing shell size and structural complexity. CT provided less variation between repeat measures but volume estimates were consistently lower compared to sand/water and will need methodological improvements before it can be used as an alternative. CT indicated volume may be also underestimated using sand/water due to the presence of air spaces visible in filled shells scanned by CT. Lastly, we encourage authors to clearly describe how volume estimates were obtained.
Zhang, Yulong; Ma, Xiaoxuan; Ran, Yong
2014-02-01
Shale was thermally treated to obtain a series of kerogen with varied maturation. Their chemical, structural and porous properties were related to the sorption and/or desorption behaviors of phenanthrene and benzene. As the treatment temperature increases, aliphatic and carbonyl carbon of the kerogen samples decrease, while their aromaticity and maturation increase. Meanwhile, the isothermal nonlinearity of phenanthrene and benzene increases whereas the sorption capacity and micropore adsorption volumes (Vo,d) initially increase and then decrease. The Vo,d of benzene is significantly correlated with, but higher than that of phenanthrene, suggesting similar micropore filling mechanism and molecular sieve effect. The benzene desorption exhibits hysteresis, which is related to the pore deformation of the kerogen and the entrapment of solute in the kerogen matrix. The Vo,d of phenanthrene and benzene on the kerogen samples accounts for 23-46% and 36-65% of the maximum sorption volumes, respectively, displaying the importance of the micropore filling. Copyright © 2013 Elsevier Ltd. All rights reserved.
Rebound and jet formation of a fluid-filled sphere
NASA Astrophysics Data System (ADS)
Killian, Taylor W.; Klaus, Robert A.; Truscott, Tadd T.
2012-12-01
This study investigates the impact dynamics of hollow elastic spheres partially filled with fluid. Unlike an empty sphere, the internal fluid mitigates some of the rebound through an impulse driven exchange of energy wherein the fluid forms a jet inside the sphere. Surprisingly, this occurs on the second rebound or when the free surface is initially perturbed. Images gathered through experimentation show that the fluid reacts more quickly to the impact than the sphere, which decouples the two masses (fluid and sphere), imparts energy to the fluid, and removes rebound energy from the sphere. The experimental results are analyzed in terms of acceleration, momentum and an energy method suggesting an optimal fill volume in the neighborhood of 30%. While the characteristics of the fluid (i.e., density, viscosity, etc.) affect the fluid motion (i.e., type and size of jet formation), the rebound characteristics remain similar for a given fluid volume independent of fluid type. Implications of this work are a potential use of similar passive damping systems in sports technology and marine engineering.
A comparative analysis of carbon dioxide displacement rates for euthanasia of the ferret.
Fitzhugh, Dawn C; Parmer, Amanda; Shelton, Larry J; Sheets, James T
2008-02-01
Though carbon dioxide asphyxiation is a common method of euthanasia for laboratory animals, species-specific guidelines have not been established for this procedure in the domestic ferret (Mustela putorius furo). The authors investigated the efficacy and stress effects of carbon dioxide euthanasia in 24 ferrets that had participated in previous experimental protocols. They euthanized ferrets by placing them in cages that were either prefilled with carbon dioxide or gradually filled at a displacement rate of 10%, 20% or 50% of the cage volume per min. Blinded observers subjectively evaluated ferret distress. Prefilling the cage or filling it at a rate of 50% volume per min resulted in less time to recumbency and to last breath than did filling the cage at a slower displacement rate. Slower carbon dioxide displacement rates also caused an increase in ferret blood glucose concentrations, which may indicate distress. Overall, observers found that prefilling the euthanasia cage caused the least stress to ferrets.
Brain responses to bladder filling in older women without urgency incontinence.
Tadic, Stasa D; Tannenbaum, Cara; Resnick, Neil M; Griffiths, Derek
2013-06-01
To investigate normal brain responses to bladder filling, especially when there is little or no sensation as in much of daily life. We performed an functional magnetic resonance imaging (fMRI) study of brain responses to bladder filling in normal female subjects, evoked by infusion and withdrawal of fluid in and out of the bladder. Using the contrast (infusion-withdrawal), we imaged brain activity at small bladder volumes with weak filling sensation and also with full bladder and strong desire to void. Eleven women, average age 65 years (range: 60-71 years) were included. With full bladder and strong desire to void, filling provoked a well-known pattern of activation near the right insula and (as a trend) in the dorsal anterior cingulate cortex and supplementary motor area. There was no significant deactivation. With small bladder volume filling provoked widespread apparent deactivation and no significant activation. Apparent deactivation was associated with increased fMRI signal during withdrawal rather than decrease during infusion, suggesting artifact. A correction for global changes in cerebral blood flow eliminated it and revealed significant subcortical activation, although none in frontal or parietal cortex. In older women with normal bladder function, infusion into an already full bladder resulted in strong sensation and brain activation near the insula and in the dorsal anterior cingulate/supplementary motor complex. With near-empty bladder and little sensation, the situation during much of daily life, these cortical areas were not detectably activated, but activation in midbrain and parahippocampal regions presumably indicated unconscious monitoring of ascending bladder signals. Copyright © 2013 Wiley Periodicals, Inc.
Jin, Cheng; Feng, Jianjiang; Wang, Lei; Yu, Heng; Liu, Jiang; Lu, Jiwen; Zhou, Jie
2018-05-01
In this paper, we present an approach for left atrial appendage (LAA) multi-phase fast segmentation and quantitative assisted diagnosis of atrial fibrillation (AF) based on 4D-CT data. We take full advantage of the temporal dimension information to segment the living, flailed LAA based on a parametric max-flow method and graph-cut approach to build 3-D model of each phase. To assist the diagnosis of AF, we calculate the volumes of 3-D models, and then generate a "volume-phase" curve to calculate the important dynamic metrics: ejection fraction, filling flux, and emptying flux of the LAA's blood by volume. This approach demonstrates more precise results than the conventional approaches that calculate metrics by area, and allows for the quick analysis of LAA-volume pattern changes of in a cardiac cycle. It may also provide insight into the individual differences in the lesions of the LAA. Furthermore, we apply support vector machines (SVMs) to achieve a quantitative auto-diagnosis of the AF by exploiting seven features from volume change ratios of the LAA, and perform multivariate logistic regression analysis for the risk of LAA thrombosis. The 100 cases utilized in this research were taken from the Philips 256-iCT. The experimental results demonstrate that our approach can construct the 3-D LAA geometries robustly compared to manual annotations, and reasonably infer that the LAA undergoes filling, emptying and re-filling, re-emptying in a cardiac cycle. This research provides a potential for exploring various physiological functions of the LAA and quantitatively estimating the risk of stroke in patients with AF. Copyright © 2018 Elsevier Ltd. All rights reserved.
Mean circulatory filling pressure: potential problems with measurement.
Gaddis, M L; Rothe, C F; Tunin, R S; Moran, M; MacAnespie, C L
1986-10-01
Three experimental series using 22 acutely splenectomized mongrel dogs were completed to 1) compare fibrillation (Fib) and acetylcholine (ACh) injection as methods to stop the heart for the mean circulatory filling pressure (Pmcf) maneuver, and 2) test whether Pmcf equals portal venous pressure 7 s after heart stoppage (Pportal7s). Blood volume changes of -10, -20, +10, or +20 ml/kg were imposed and Pmcf and Pportal measurements were obtained. Pportal7s and Pmcf were significantly different with volume depletion but were similar under control conditions. Pmcf with ACh and Pmcf with Fib were significantly different only after a volume change of -20 ml/kg. However, severe pulmonary congestion and atelectasis were detected in animals where Ach was used to stop the heart. In some cases (with injection directly into the pulmonary artery) the damage was severe enough to cause irreversible arterial hypoxia. Thus we conclude that the repeated use of ACh may exert a detrimental influence on pulmonary function, changing the physiological status of the experimental animal. Also, the central venous pressure at 7 s of heart stoppage (Pcv7s) is not a fully accurate estimate of the true mean circulatory filling pressure during the Pmcf maneuver, because Pcv7s did not equal the Pportal7s under all experimental conditions.
Silva, E J; Perez, R; Valentim, R M; Belladonna, F G; De-Deus, G A; Lima, I C; Neves, A A
2017-04-01
To evaluate, using a novel micro-CT approach, the solubility and dimensional changes of an MTA-based sealer inside the root canal system after a solubility challenge. The MTA-based material (MTA Fillapex) was compared to a gold standard epoxy-based endodontic sealer (AH Plus). Ten human mandibular premolars with a single canal were divided randomly into two groups (n = 5) according to the sealer used. The canals were instrumented using the Reciproc System (VDW) with a R40 file and filled with R40 gutta-percha cones and one of the sealers. The filled canals were immediately scanned in a micro-CT, and after that, the teeth were immersed in 20 mL phosphate-buffered saline (PBS) at 37 °C for 7 days, when they were removed and rescanned. Final image stacks were registered against the initial stacks and the numerical difference between the initial and final volume of the filling material was obtained. Calculations were performed to identify dimensional changes of the filling material. All image stacks were 3D rendered to disclose areas of dislocation of the filling material inside or outside the root canal. The Shapiro-Wilk's test revealed that data were normally distributed; thus, the Student's t-test was used to detect statistically significant changes, assuming a 5% α-error. No significant changes were seen for the percentage volume of material lost after the solubility challenge for both AH Plus and MTA Fillapex groups (1.44% and 1.16%, respectively). A significant difference was, however, found for the volume of filling material which revealed dimensional changes after the solubility test (6.68% for MTA Fillapex and 1.09% for AH Plus). In fact, observation of 3D models disclosed that MTA Fillapex was associated with material extrusion through the foramen in all but one sample. In AH Plus filled samples, no material extrusion was detected. Although the solubility of both sealers was similar using this novel micro-CT approach, MTA Fillapex was associated with significant dimensional changes related to material extrusion through the apex after PBS storage compared to AH Plus. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.
DOT National Transportation Integrated Search
2012-06-01
Production of Portland Cement for concrete is a major source of CO2 emission. Concrete can be made more sustainable by replacing a large volume of the cement with Supplementary Cementitous Materials (SCMs) such as fly ash and slag. The amount of ceme...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Massie, B.; Kramer, B.L.; Topic, N.
Although the resting hemodynamic effects of captopril in congestive heart failure are known, little information is available about the hemodynamic response to captopril during exercise or about changes in noninvasive measurements of the size and function of both ventricles. In this study, 14 stable New York Heart Association class III patients were given 25 mg of oral captopril. Rest and exercise hemodynamic measurements and blood pool scintigrams were performed simultaneously before and 90 minutes after captopril. The radionuclide studies were analyzed for left and right ventricular end-diastolic volumes, end-systolic volumes, ejection fractions and pulmonary blood volume. The primary beneficial responsesmore » at rest were decreases in left and right ventricular end-diastolic volumes from 388 +/- 81 to 350 +/- 77 ml and from 52 +/- 26 to 43 +/- 20 volume units, respectively, and in their corresponding filling pressures, from 24 +/- 10 to 17 +/- 9 mm Hg and 10 +/- 5 to 6 +/- 5 mm Hg. Although stroke volume did not increase significantly, both left and right ventricular ejection fractions increased slightly, from 19 +/- 6% to 22+/- 5% and from 25 +/- 9% to 29 +/- 11%, respectively. During exercise, similar changes were noted in both hemodynamic and radionuclide indexes. This, in patients with moderate symptomatic limitation from chronic heart failure, captopril predominantly reduces ventricular volume and filling pressure, with a less significant effect on cardiac output. These effects persist during exercise, when systemic vascular resistance is already very low. Radionuclide techniques are valuable in assessing the drug effect in these subjects, particularly when ventricular volumes are also measured.« less
Hydraulic modeling of clay ceramic water filters for point-of-use water treatment.
Schweitzer, Ryan W; Cunningham, Jeffrey A; Mihelcic, James R
2013-01-02
The acceptability of ceramic filters for point-of-use water treatment depends not only on the quality of the filtered water, but also on the quantity of water the filters can produce. This paper presents two mathematical models for the hydraulic performance of ceramic water filters under typical usage. A model is developed for two common filter geometries: paraboloid- and frustum-shaped. Both models are calibrated and evaluated by comparison to experimental data. The hydraulic models are able to predict the following parameters as functions of time: water level in the filter (h), instantaneous volumetric flow rate of filtrate (Q), and cumulative volume of water produced (V). The models' utility is demonstrated by applying them to estimate how the volume of water produced depends on factors such as the filter shape and the frequency of filling. Both models predict that the volume of water produced can be increased by about 45% if users refill the filter three times per day versus only once per day. Also, the models predict that filter geometry affects the volume of water produced: for two filters with equal volume, equal wall thickness, and equal hydraulic conductivity, a filter that is tall and thin will produce as much as 25% more water than one which is shallow and wide. We suggest that the models can be used as tools to help optimize filter performance.
Optical properties study of nano-composite filled D shape photonic crystal fibre
NASA Astrophysics Data System (ADS)
Udaiyakumar, R.; Mohamed Junaid, K. A.; Janani, T.; Maheswar, R.; Yupapin, P.; Amiri, I. S.
2018-06-01
With the nano-composite materials gaining momentum in the optical field, a new nano-composite filled D shape Photonic Crystal Fiber (PCF) is designed and the various optical properties are investigated with help of Finite Element Method. In the proposed structure the D-shape PCF is made up of silica with embedded silver nanoparticles and air holes are distributed along the fibre. The designed fibre shows various optical properties such as dispersion, birefringence, beat length and loss with respect to wavelength and compared with different filling factor like 0.1, 0.3 and 0.5. From our estimation and comparative analysis, it has been proved that the fibre loss has been decreased with increasing filling factor. Further this also showed flat dispersion at maximum filling factor.
Wu, Gang; Liu, Yuelian; Iizuka, Tateyuki; Hunziker, Ernst Bruno
2010-10-01
We investigated the inflammatory response to, and the osteoinductive efficacies of, four polymers (collagen, Ethisorb, PLGA and Polyactive) that bore either an adsorbed (fast-release kinetics) or a calcium-phosphate-coating-incorporated (slow-release kinetics) depot of BMP-2. Titanium-plate-supported discs of each polymer (n = 6 per group) were implanted at an ectopic (subcutaneous) ossification site in rats (n = 48). Five weeks later, they were retrieved for a histomorphometric analysis of the volumes of ectopic bone and foreign-body giant cells (a gauge of inflammatory reactivity), and the degree of polymer degradation. For each polymer, the osteoinductive efficacy of BMP-2 was higher when it was incorporated into a coating than when it was directly adsorbed onto the material. This mode of BMP-2 carriage was consistently associated with an attenuation of the inflammatory response. For coated materials, the volume density of foreign-body giant cells was inversely correlated with the volume density of bone (r(2) = 0.96), and the volume density of bone was directly proportional to the surface-area density of the polymer (r(2) = 0.97). Following coating degradation, other competitive factors, such as the biocompatibility and the biodegradability of the polymer itself, came into play. 2010 Elsevier Ltd. All rights reserved.
The effects of temperature on nitrous oxide and oxygen mixture homogeneity and stability.
Litwin, Patrick D
2010-10-15
For many long standing practices, the rationale for them is often lost as time passes. This is the situation with respect to the storage and handling of equimolar 50% nitrous oxide and 50% oxygen volume/volume (v/v) mixtures. A review was undertaken of existing literature to examine the developmental history of nitrous oxide and oxygen mixtures for anesthesia and analgesia and to ascertain if sufficient bibliographic data was available to support the position that the contents of a cylinder of a 50%/50% volume/volume (v/v) mixture of nitrous oxide and oxygen is in a homogenous single gas phase in a filled cylinder under normal conditions of handling and storage and if justification could be found for the standard instructions given for handling before use. After ranking and removing duplicates, a total of fifteen articles were identified by the various search strategies and formed the basis of this literature review. Several studies were identified that confirmed that 50%/50% v/v mixture of nitrous oxide and oxygen is in a homogenous single gas phase in a filled cylinder under normal conditions of handling and storage. The effect of temperature on the change of phase of the nitrous oxide in this mixture was further examined by several authors. These studies demonstrated that although it is possible to cause condensation and phase separation by cooling the cylinder, by allowing the cylinder to rewarm to room temperature for at least 48 hours, preferably in a horizontal orientation, and inverting it three times before use, the cylinder consistently delivered the proper proportions of the component gases as a homogenous mixture. The contents of a cylinder of a 50%/50% volume/volume (v/v) mixture of nitrous oxide and oxygen is in a homogenous single gas phase in a filled cylinder under normal conditions of handling and storage. The standard instructions given for handling before are justified based on previously conducted studies.
NASA Astrophysics Data System (ADS)
Samui, Saumyadip; Subramanian, Kandaswamy; Srianand, Raghunathan
2018-05-01
We present semi-analytical models of galactic outflows in high-redshift galaxies driven by both hot thermal gas and non-thermal cosmic rays. Thermal pressure alone may not sustain a large-scale outflow in low-mass galaxies (i.e. M ˜ 108 M⊙), in the presence of supernovae feedback with large mass loading. We show that inclusion of cosmic ray pressure allows outflow solutions even in these galaxies. In massive galaxies for the same energy efficiency, cosmic ray-driven winds can propagate to larger distances compared to pure thermally driven winds. On an average gas in the cosmic ray-driven winds has a lower temperature which could aid detecting it through absorption lines in the spectra of background sources. Using our constrained semi-analytical models of galaxy formation (that explains the observed ultraviolet luminosity functions of galaxies), we study the influence of cosmic ray-driven winds on the properties of the intergalactic medium (IGM) at different redshifts. In particular, we study the volume filling factor, average metallicity, cosmic ray and magnetic field energy densities for models invoking atomic cooled and molecular cooled haloes. We show that the cosmic rays in the IGM could have enough energy that can be transferred to the thermal gas in presence of magnetic fields to influence the thermal history of the IGM. The significant volume filling and resulting strength of IGM magnetic fields can also account for recent γ-ray observations of blazars.
NASA Astrophysics Data System (ADS)
Pathak, R. K. P.; Pei, X.; Hallquist, M.; Pagels, J. H.
2017-12-01
Morphological transformation of soot particle by condensation of low volatility materials on it is a dominant atmospheric process with serious implications for its optical and hygroscopic properties, and atmospheric lifetime. In this study, the morphological transformation of soot agglomerate under the influence of condensation of vapours of sulphuric acid, and/or limonene ozonolysis products were investigated systematically using a Differential Mobility Analyser-Aerosol Particle Mass Analyser (DMA-APM) and the Tandem DMA techniques integrated with a laminar flow-tube system. We discovered that the morphology transformation of soot in general was a sequence of two-step process, i.e. (i) filling of void space within soot agglomerate; (ii) growth of particle diameter. These two steps followed and complimented each other. In the very beginning the filling was the dominant process followed by growth until it led to the accumulation of enough material that in turn exerted surface forces that eventually facilitated the further filling. The filling of void space was constrained by the initial morphology of fresh soot and the nature and amount of the material condensed. This process continued in several sequential steps until all void space within the soot agglomerate was filled completely and then growth of a spherical particle continued as long as mass was condensed on it. In this study, we developed a framework to quantify the microphysical transformation of soot upon the condensation of various materials. The framework utilized experimental data and hypothesis of ideal sphere growth and filling of voids to quantify the distribution of condensed materials in these two processes complimenting each other. Using this framework, we have quantified the percentage of material that went into processes of particle growth and void filling at each step. Using the same framework, we further estimated the fraction of internal voids and open voids and used this information to derive the volume equivalent diameter of soot agglomerate containing internal voids and calculated in-situ dynamic shape factor. Our study is the first study that tracks in situ microphysical changes in soot morphology quantitatively, providing the detailed status of both fresh and coated soot particles.
Jhingran, Anuja; Salehpour, Mohammad; Sam, Marianne; Levy, Larry; Eifel, Patricia J
2012-01-01
To evaluate variations in bladder and rectal volume and the position of the vaginal vault during a 5-week course of pelvic intensity-modulated radiation therapy (IMRT) after hysterectomy. Twenty-four patients were instructed how to fill their bladders before simulation and treatment. These patients underwent computed tomography simulations with full and empty bladders and then underwent rescanning twice weekly during IMRT; patients were asked to have full bladder for treatment. Bladder and rectal volumes and the positions of vaginal fiducial markers were determined, and changes in volume and position were calculated. The mean full and empty bladder volumes at simulation were 480 cc (range, 122-1,052) and 155 cc (range, 49-371), respectively. Bladder volumes varied widely during IMRT: the median difference between the maximum and minimum volumes was 247 cc (range, 96-585). Variations in rectal volume during IMRT were less pronounced. For the 16 patients with vaginal fiducial markers in place throughout IMRT, the median maximum movement of the markers during IMRT was 0.59 cm in the right-left direction (range, 0-0.9), 1.46 cm in the anterior-posterior direction (range, 0.8-2.79), and 1.2 cm in the superior-inferior direction (range, 0.6-2.1). Large variations in rectal or bladder volume frequently correlated with significant displacement of the vaginal apex. Although treatment with a full bladder is usually preferred because of greater sparing of small bowel, our data demonstrate that even with detailed instruction, patients are unable to maintain consistent bladder filling. Variations in organ position during IMRT can result in marked changes in the position of the target volume and the volume of small bowel exposed to high doses of radiation. Copyright © 2012 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jhingran, Anuja, E-mail: ajhingra@mdanderson.org; Salehpour, Mohammad; Sam, Marianne
2012-01-01
Purpose: To evaluate variations in bladder and rectal volume and the position of the vaginal vault during a 5-week course of pelvic intensity-modulated radiation therapy (IMRT) after hysterectomy. Methods and Materials: Twenty-four patients were instructed how to fill their bladders before simulation and treatment. These patients underwent computed tomography simulations with full and empty bladders and then underwent rescanning twice weekly during IMRT; patients were asked to have full bladder for treatment. Bladder and rectal volumes and the positions of vaginal fiducial markers were determined, and changes in volume and position were calculated. Results: The mean full and empty bladdermore » volumes at simulation were 480 cc (range, 122-1,052) and 155 cc (range, 49-371), respectively. Bladder volumes varied widely during IMRT: the median difference between the maximum and minimum volumes was 247 cc (range, 96-585). Variations in rectal volume during IMRT were less pronounced. For the 16 patients with vaginal fiducial markers in place throughout IMRT, the median maximum movement of the markers during IMRT was 0.59 cm in the right-left direction (range, 0-0.9), 1.46 cm in the anterior-posterior direction (range, 0.8-2.79), and 1.2 cm in the superior-inferior direction (range, 0.6-2.1). Large variations in rectal or bladder volume frequently correlated with significant displacement of the vaginal apex. Conclusion: Although treatment with a full bladder is usually preferred because of greater sparing of small bowel, our data demonstrate that even with detailed instruction, patients are unable to maintain consistent bladder filling. Variations in organ position during IMRT can result in marked changes in the position of the target volume and the volume of small bowel exposed to high doses of radiation.« less
The plasma filling factor of coronal bright points. II. Combined EIS and TRACE results
NASA Astrophysics Data System (ADS)
Dere, K. P.
2009-04-01
Aims: In a previous paper, the volumetric plasma filling factor of coronal bright points was determined from spectra obtained with the Extreme ultraviolet Imaging Spectrometer (EIS). The analysis of these data showed that the median plasma filling factor was 0.015. One interpretation of this result was that the small filling factor was consistent with a single coronal loop with a width of 1-2´´, somewhat below the apparent width. In this paper, higher spatial resolution observations with the Transition Region and Corona Explorer (TRACE) are used to test this interpretation. Methods: Rastered spectra of regions of the quiet Sun were recorded by the EIS during operations with the Hinode satellite. Many of these regions were simultaneously observed with TRACE. Calibrated intensities of Fe xii lines were obtained and images of the quiet corona were constructed from the EIS measurements. Emission measures were determined from the EIS spectra and geometrical widths of coronal bright points were obtained from the TRACE images. Electron densities were determined from density-sensitive line ratios measured with EIS. A comparison of the emission measure and bright point widths with the electron densities yielded the plasma filling factor. Results: The median electron density of coronal bright points is 3 × 109 cm-3 at a temperature of 1.6 × 106 K. The volumetric plasma filling factor of coronal bright points was found to vary from 3 × 10-3 to 0.3 with a median value of 0.04. Conclusions: The current set of EIS and TRACE coronal bright-point observations indicate the median value of their plasma filling factor is 0.04. This can be interpreted as evidence of a considerable subresolution structure in coronal bright points or as the result of a single completely filled plasma loop with widths on the order of 0.2-1.5´´ that has not been spatially resolved in these measurements.
NASA Astrophysics Data System (ADS)
Abd Kadir, N.; Aminanda, Y.; Ibrahim, M. S.; Mokhtar, H.
2016-10-01
A statistical analysis was performed to evaluate the effect of factor and to obtain the optimum configuration of Kraft paper honeycomb. The factors considered in this study include density of paper, thickness of paper and cell size of honeycomb. Based on three level factorial design, two-factor interaction model (2FI) was developed to correlate the factors with specific energy absorption and specific compression strength. From the analysis of variance (ANOVA), the most influential factor on responses and the optimum configuration was identified. After that, Kraft paper honeycomb with optimum configuration is used to fabricate foam-filled paper honeycomb with five different densities of polyurethane foam as filler (31.8, 32.7, 44.5, 45.7, 52 kg/m3). The foam-filled paper honeycomb is subjected to quasi-static compression loading. Failure mechanism of the foam-filled honeycomb was identified, analyzed and compared with the unfilled paper honeycomb. The peak force and energy absorption capability of foam-filled paper honeycomb are increased up to 32% and 30%, respectively, compared to the summation of individual components.
Thermal Performance Evaluation of Walls with Gas Filled Panel Insulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shrestha, Som S.; Desjarlais, Andre Omer; Atchley, Jerald Allen
Gas filled insulation panels (GFP) are very light weight and compact (when uninflated) advanced insulation products. GFPs consist of multiple layers of thin, low emittance (low-e) metalized aluminum. When expanded, the internal, low-e aluminum layers form a honeycomb structure. These baffled polymer chambers are enveloped by a sealed barrier and filled with either air or a low-conductivity gas. The sealed exterior aluminum foil barrier films provide thermal resistance, flammability protection, and properties to contain air or a low conductivity inert gas. This product was initially developed with a grant from the U.S. Department of Energy. The unexpanded product is nearlymore » flat for easy storage and transport. Therefore, transportation volume and weight of the GFP to fill unit volume of wall cavity is much smaller compared to that of other conventional insulation products. This feature makes this product appealing to use at Army Contingency Basing, when transportation cost is significant compared to the cost of materials. The objective of this study is to evaluate thermal performance of walls, similar to those used at typical Barracks Hut (B-Hut) hard shelters, when GFPs are used in the wall cavities. Oak Ridge National Laboratory (ORNL) tested performance of the wall in the rotatable guarded hotbox (RGHB) according to the ASTM C 1363 standard test method.« less
NASA Astrophysics Data System (ADS)
Aguiar, P.; González-Castaño, D. M.; Gómez, F.; Pardo-Montero, J.
2014-10-01
Liquid-filled ionisation chambers (LICs) are used in radiotherapy for dosimetry and quality assurance. Volume recombination can be quite important in LICs for moderate dose rates, causing non-linearities in the dose rate response of these detectors, and needs to be corrected for. This effect is usually described with Greening and Boag models for continuous and pulsed radiation respectively. Such models assume that the charge is carried by two different species, positive and negative ions, each of those species with a given mobility. However, LICs operating in non-ultrapure mode can contain different types of electronegative impurities with different mobilities, thus increasing the number of different charge carriers. If this is the case, Greening and Boag models can be no longer valid and need to be reformulated. In this work we present a theoretical and numerical study of volume recombination in parallel-plate LICs with multiple charge carrier species, extending Boag and Greening models. Results from a recent publication that reported three different mobilities in an isooctane-filled LIC have been used to study the effect of extra carrier species on recombination. We have found that in pulsed beams the inclusion of extra mobilities does not affect volume recombination much, a behaviour that was expected because Boag formula for charge collection efficiency does not depend on the mobilities of the charge carriers if the Debye relationship between mobilities and recombination constant holds. This is not the case in continuous radiation, where the presence of extra charge carrier species significantly affects the amount of volume recombination.
Development of a 3D Filling Model of Low-Pressure Die-Cast Aluminum Alloy Wheels
NASA Astrophysics Data System (ADS)
Duan, Jianglan; Maijer, Daan; Cockcroft, Steve; Reilly, Carl
2013-12-01
A two-phase computational fluid dynamics model of the low-pressure die-cast process for the production of A356 aluminum alloy wheels has been developed to predict the flow conditions during die filling. The filling model represents a 36-deg section of a production wheel, and was developed within the commercial finite-volume package, ANSYS CFX, assuming isothermal conditions. To fully understand the behavior of the free surface, a novel technique was developed to approximate the vent resistances as they impact on the development of a backpressure within the die cavity. The filling model was first validated against experimental data, and then was used to investigate the effects of venting conditions and pressure curves during die filling. It was found that vent resistance and vent location strongly affected die filling time, free surface topography, and air entrainment for a given pressure fill-curve. With regard to the pressure curve, the model revealed a strong relation between the pressure curve and the flow behavior in the hub, which is an area prone to defect formation.
ERIC Educational Resources Information Center
de Berg, Kevin; Chapman, Ken
1996-01-01
Describes an alternative technique for determining the molar volume of hydrogen from the metal-acid reaction in which the metal sample is encased in a specially prepared cage and a pipette filler is used to fill an inverted burette with water. Eliminates some difficulties encountered with the conventional technique. (JRH)
The Shape of a Sausage: A Challenging Problem in the Calculus of Variations
ERIC Educational Resources Information Center
Deakin, Michael A. B.
2010-01-01
Many familiar household objects (such as sausages) involve the maximization of a volume under geometric constraints. A flexible but inextensible membrane bounds a volume which is to be filled to capacity. In the case of the sausage, a full analytic solution is here provided. Other related but more difficult problems seem to demand approximate…
de Oliveira Correia, Ayla Macyelle; Tribst, João Paulo Mendes; de Souza Matos, Felipe; Platt, Jeffrey A; Caneppele, Taciana Marco Ferraz; Borges, Alexandre Luiz Souto
2018-06-20
This study evaluated the effect of different restorative techniques for non-carious cervical lesions (NCCL) on polymerization shrinkage stress of resins using three-dimensional (3D) finite element analysis (FEA). 3D-models of a maxillary premolar with a NCCL restored with different filling techniques (bulk filling and incremental) were generated to be compared by nonlinear FEA. The bulk filling technique was used for groups B (NCCL restored with Filtek™ Bulk Fill) and C (Filtek™ Z350 XT). The incremental technique was subdivided according to mode of application: P (2 parallel increments of the Filtek™ Z350 XT), OI (2 oblique increments of the Filtek™ Z350 XT, with incisal first), OIV (2 oblique increments of the Filtek™ Z350 XT, with incisal first and increments with the same volume), OG (2 oblique increments of the Filtek™ Z350 XT, with gingival first) and OGV (2 oblique increments of the Filtek™ Z350 XT, with gingival first and increments with the same volume), resulting in 7 models. All materials were considered isotropic, elastic and linear. The results were expressed in maximum principal stress (MPS). The tension stress distribution was influenced by the restorative technique. The lowest stress concentration occurred in group B followed by OG, OGV, OI, OIV, P and C; the incisal interface was more affected than the gingival. The restoration of NCCLs with bulk fill composite resulted in lower shrinkage stress in the gingival and incisal areas, followed by incremental techniques with the initial increment placed on the gingival wall. The non-carious cervical lesions (NCCLs) restored with bulk fill composite have a more favorable biomechanical behavior. Copyright © 2018. Published by Elsevier Ltd.
Khedmat, Sedigheh; Azari, Abbas; Shamshiri, Ahmad Reza; Fadae, Mehdi; Bashizadeh Fakhar, Hoorieh
2016-01-01
Introduction: The aim of this in vitro study was to compare the efficacy of ProTaper retreatment (ProTaper R) and Mtwo retreatment (Mtwo R) files in removing gutta-percha and GuttaFlow from endodontically treated straight root canals. Methods and Materials: The root canals of 60 human mandibular single-rooted premolars were prepared and randomly divided into two groups (n=30). In groups A and B the root canals were obturated using lateral condensation of gutta-percha plus AH 26 and GuttaFlow, respectively. The canal orifices were temporarily sealed and the roots were incubated for 3 months at 37ºC and 100% humidity. Primary cone-beam computed tomography (CBCT) images were taken after incubation period. The specimens in each group were randomly divided into two subgroups (n=15). ProTaper R files (D1, D2, and D3) were used in groups A1 and B1 while Mtwo R files (25/0.05 and 15/0.05) were used in groups A2 and B2. The time required to extirpate the root filling was also recorded. After retreatment, another CBCT scan was taken at the same position. The volume of remaining filling materials inside the canals was calculated before and after retreatment. The data was analyzed using the two-way ANOVA and independent t-test. Results: The remaining filling materials in the canals treated with ProTaper were less than Mtwo. The remaining volume of GuttaFlow was less than gutta-percha regardless of the system applied. Mtwo R files removed root fillings faster than ProTaper R. Conclusion: ProTaper R removed filling material more efficiently compared to Mtwo R which required less time to remove root filling material. PMID:27471528
Ambartsumyan, Lusine; Siddiqui, Anees; Bauer, Stuart; Nurko, Samuel
2016-01-01
Background Children with urinary incontinence (UI) have associated functional constipation (FC) and fecal incontinence (FI). The physiology between lower urinary tract (LUT) and anorectum in children has not been elucidated. Aims Observe the effect of rectal distention (RD) on LUT function, and bladder filling and voiding on anorectal function. Methods Children with voiding dysfunction referred to Boston Children’s Hospital were prospectively enrolled for combined urodynamic (UDS) and anorectal manometry (ARM). Anorectal and urodynamic parameters were simultaneously measured. Patients underwent 2 micturition cycles, 1st with rectal balloon deflated and 2nd with it inflated (RD). LUT and anorectal parameters were compared between cycles. Key Results 10 children (7 UI, 4 recurrent UTIs, 9 FC ± FI) were enrolled. Post void residual (PVR) increased (p=0.02) with RD. No differences were observed in percent of bladder filling to expected bladder capacity, sensation, and bladder compliance with and without RD. Bladder and abdominal pressures increased at voiding with RD (p<0.05). Intra-anal pressures decreased at voiding (p<0.05), at 25% (p=0.03) and 50% (p=0.06) of total volume of bladder filling. Conclusions & Inferences The PVR volume increased with RD. Stool in the rectum does not alter filling cystometric capacity but decreases the bladder’s ability to empty predisposing patients with fecal retention to UI and UTIs. Bladder and abdominal pressures increased during voiding demonstrating a physiological correlate of dysfunctional voiding. Intra-anal pressures decreased during bladder filling and voiding. This is the first time intra-anal relaxation during bladder filling and voiding has been described. PMID:27214097
DOE Office of Scientific and Technical Information (OSTI.GOV)
Majewski, Wojciech, E-mail: wmajewski1@poczta.onet.p; Wesolowska, Iwona; Urbanczyk, Hubert
2009-12-01
Purpose: To estimate bladder movements and changes in dose distribution in the bladder and surrounding tissues associated with changes in bladder filling and to estimate the internal treatment margins. Methods and Materials: A total of 16 patients with bladder cancer underwent planning computed tomography scans with 80- and 150-mL bladder volumes. The bladder displacements associated with the change in volume were measured. Each patient had treatment plans constructed for a 'partially empty' (80 mL) and a 'partially full' (150 mL) bladder. An additional plan was constructed for tumor irradiation alone. A subsequent 9 patients underwent sequential weekly computed tomography scanningmore » during radiotherapy to verify the bladder movements and estimate the internal margins. Results: Bladder movements were mainly observed cranially, and the estimated internal margins were nonuniform and largest (>2 cm) anteriorly and cranially. The dose distribution in the bladder worsened if the bladder increased in volume: 70% of patients (11 of 16) would have had bladder underdosed to <95% of the prescribed dose. The dose distribution in the rectum and intestines was better with a 'partially empty' bladder (volume that received >70%, 80%, and 90% of the prescribed dose was 23%, 20%, and 15% for the rectum and 162, 144, 123 cm{sup 3} for the intestines, respectively) than with a 'partially full' bladder (volume that received >70%, 80%, and 90% of the prescribed dose was 28%, 24%, and 18% for the rectum and 180, 158, 136 cm{sup 3} for the intestines, respectively). The change in bladder filling during RT was significant for the dose distribution in the intestines. Tumor irradiation alone was significantly better than whole bladder irradiation in terms of organ sparing. Conclusion: The displacements of the bladder due to volume changes were mainly related to the upper wall. The internal margins should be nonuniform, with the largest margins cranially and anteriorly. The changes in bladder filling during RT could influence the dose distribution in the bladder and intestines. The dose distribution in the rectum and bowel was slightly better with a 'partially empty' than with a 'full' bladder.« less
Dust near luminous ultraviolet stars
NASA Technical Reports Server (NTRS)
Henry, Richard C.
1992-01-01
More than 700 luminous stars in the infrared astronomical satellite (IRAS) Skyflux plates were examined for the presence of dust heated by a nearby star. This dust may be distinguished from the ubiquitous cool cirrus by its higher temperature and thus enhanced 60 micron emission. More than 120 dust clouds were found around only 106 of the stars with a volume filling factor of 0.006 and an intercloud separation of 46 pc. A region of dust smoothly distributed through the volume of space heated by the star could not be found and hence an upper limit of 0.05 cm(exp -3) is placed on the equivalent gas density in the intercloud regions. The clouds have an average density of 0.22 cm(exp -3) and a radius of 1.9 pc, albeit with wide variations in their properties. Two different scale heights of 140 and 540 pc were found. This was interpreted as evidence for different distributions of dust in and out of the galactic disk.
Willems, Elise; Smismans, Annick; Cartuyvels, Reinoud; Coppens, Guy; Van Vaerenbergh, Kristien; Van den Abeele, Anne-Marie; Frans, Johan
2012-05-01
Bloodstream infections remain a major challenge in medicine. Optimal detection of pathogens is only possible if the quality of preanalytical factors is thoroughly controlled. Since the laboratory is responsible for this preanalytical phase, the quality control of critical factors should be integrated in its quality control program. The numerous recommendations regarding blood culture collection contain controversies. Only an unambiguous guideline permits standardization and interlaboratory quality control. We present an evidence-based concise guideline of critical preanalytical determinants for blood culture collection and summarize key performance indicators with their concomitant target values. In an attempt to benchmark, we compared the true-positive rate, contamination rate, and collected blood volume of blood culture bottles in 5 Belgian hospital laboratories. The true-positive blood culture rate fell within previously defined acceptation criteria by Baron et al. (2005) in all 5 hospitals, whereas the contamination rate exceeded the target value in 4 locations. Most unexpected, in each of the 5 laboratories, more than one third of the blood culture bottles were incorrectly filled, irrespective of the manufacturer of the blood culture vials. As a consequence of this shortcoming, one manufacturer recently developed an automatic blood volume monitoring system. In conclusion, clear recommendations for standardized blood culture collection combined with quality control of critical factors of the preanalytical phase are essential for diagnostic blood culture improvement. Copyright © 2012 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Massie, B.; Kramer, B.L.; Topic, N.
Although the resting hemodynamic effects of captopril in congestive heart failure are known, little information is available about the hemodynamic response to captopril during exercise or about changes in noninvasive measurements of the size and function of both ventricles. In this study, 14 stable New York Heart Association class III patients were given 25 mg of oral captopril. Rest and exercise hemodynamic measurements and blood pool scintigrams were performed simultaneously before and 90 minutes after captopril. The radionuclide studies were analyzed for left and right ventricular end-diastolic volumes, end-systolic volumes, ejection fractions and pulmonary blood volume. The primary beneficial responsesmore » at rest were decreases in left and right ventricular end-diastolic volumes from 388 + 81 to 350 + 77 ml (p < 0.01) and from 52 + 26 to 43 + 20 volume units (p < 0.01), respectively, and in their corresponding filling pressures, from 24 + 10 to 17 + 9 mm Hg and 10 + 5 to and + 5 mm Hg (both p < 0.01). Altough stroke volume did not increase significantly, both left and right ventricular ejection fractions increased slightly, from 19 + 6% to 22 + 5% and from 25 + 9% to 29 + 11%, respectively (both p < 0.01). During exercise, similar changes were noted in both hemodynamic and radionuclide indexes. Thus, in patients with moderate symptomatic limitation from chronic heart failure, captopril predominantly reduces ventricular volume and filling pressure, with a less significant effect on cardiac output. These effects persist during exercise, when systemic vascular resistance is already very low. Radionuclide techniques are valuable in assessing the drug effect in these subjects, particularly when ventricular volumes are also measured.« less
Hazard Analysis of Pollution Abatement Techniques. Volume I
1974-06-01
present hazards during startup/shutdown operations when filling or emptying the diatomaceous earth filters, or when filling or emptying the carbon...columns. Frictional initi- I ation modes can occur in the filter due to movement of diatomaceous earth 1< over a sufficiently dry TN~T layer. nie b...said operation. .,I addition, contaminaited diatomaceous earth should not be handled in a dry condition. Spent carbon, as well as spent earth , should be
1990-08-30
concrete-soil-concrete and other soil-filled elements as well as earth embankments of different shapes. The design of the shielding external walls...to vent entirely through the doors. This was required because the large amount of earth fill on the roofs, required for radiation shielding , precluded...Safety Window Shield to Protect Against External Explosions ...... ............... ................... 783 R. L. Shope, W. A. Keenan Strenghtening
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas, R.C.; Aldering, G.; Antilogus, P.
2006-10-12
We present four spectra of the Type Ia supernova SN Ia 2006Dextending from -7 to +13 days with respect to B-band maximum. The spectrainclude the strongest signature of unburned material at photosphericvelocities observed in a SN Ia to date. The earliest spectrum exhibits CII absorption features below 14,000 km/s, including a distinctive C IIlambda 6580 absorption feature. The carbon signatures dissipate as the SNapproaches peak brightness. In addition to discussing implications ofphotospheric-velocity carbon for white dwarf explosion models, we outlinesome factors that may influence the frequency of its detection before andaround peak brightness. Two effects are explored in this regard,includingmore » depopulation of the C II optical levels by non-LTE effects, andline-of-sight effects resulting from a clumpy distribution of unburnedmaterial with low volume-filling factor.« less
Extending the applicability of the Goldschmidt tolerance factor to arbitrary ionic compounds
Sato, Toyoto; Takagi, Shigeyuki; Deledda, Stefano; Hauback, Bjørn C.; Orimo, Shin-ichi
2016-01-01
Crystal structure determination is essential for characterizing materials and their properties, and can be facilitated by various tools and indicators. For instance, the Goldschmidt tolerance factor (T) for perovskite compounds is acknowledged for evaluating crystal structures in terms of the ionic packing. However, its applicability is limited to perovskite compounds. Here, we report on extending the applicability of T to ionic compounds with arbitrary ionic arrangements and compositions. By focussing on the occupancy of constituent spherical ions in the crystal structure, we define the ionic filling fraction (IFF), which is obtained from the volumes of crystal structure and constituent ions. Ionic compounds, including perovskites, are arranged linearly by the IFF, providing consistent results with T. The linearity guides towards finding suitable unit cell and composition, thus tackling the main obstacle for determining new crystal structures. We demonstrate the utility of the IFF by solving the structure of three hydrides with new crystal structures. PMID:27032978
Extending the applicability of the Goldschmidt tolerance factor to arbitrary ionic compounds.
Sato, Toyoto; Takagi, Shigeyuki; Deledda, Stefano; Hauback, Bjørn C; Orimo, Shin-ichi
2016-04-01
Crystal structure determination is essential for characterizing materials and their properties, and can be facilitated by various tools and indicators. For instance, the Goldschmidt tolerance factor (T) for perovskite compounds is acknowledged for evaluating crystal structures in terms of the ionic packing. However, its applicability is limited to perovskite compounds. Here, we report on extending the applicability of T to ionic compounds with arbitrary ionic arrangements and compositions. By focussing on the occupancy of constituent spherical ions in the crystal structure, we define the ionic filling fraction (IFF), which is obtained from the volumes of crystal structure and constituent ions. Ionic compounds, including perovskites, are arranged linearly by the IFF, providing consistent results with T. The linearity guides towards finding suitable unit cell and composition, thus tackling the main obstacle for determining new crystal structures. We demonstrate the utility of the IFF by solving the structure of three hydrides with new crystal structures.
Water inventory management in condenser pool of boiling water reactor
Gluntz, Douglas M.
1996-01-01
An improved system for managing the water inventory in the condenser pool of a boiling water reactor has means for raising the level of the upper surface of the condenser pool water without adding water to the isolation pool. A tank filled with water is installed in a chamber of the condenser pool. The water-filled tank contains one or more holes or openings at its lowermost periphery and is connected via piping and a passive-type valve (e.g., squib valve) to a high-pressure gas-charged pneumatic tank of appropriate volume. The valve is normally closed, but can be opened at an appropriate time following a loss-of-coolant accident. When the valve opens, high-pressure gas inside the pneumatic tank is released to flow passively through the piping to pressurize the interior of the water-filled tank. In so doing, the initial water contents of the tank are expelled through the openings, causing the water level in the condenser pool to rise. This increases the volume of water available to be boiled off by heat conducted from the passive containment cooling heat exchangers. 4 figs.
Water inventory management in condenser pool of boiling water reactor
Gluntz, D.M.
1996-03-12
An improved system for managing the water inventory in the condenser pool of a boiling water reactor has means for raising the level of the upper surface of the condenser pool water without adding water to the isolation pool. A tank filled with water is installed in a chamber of the condenser pool. The water-filled tank contains one or more holes or openings at its lowermost periphery and is connected via piping and a passive-type valve (e.g., squib valve) to a high-pressure gas-charged pneumatic tank of appropriate volume. The valve is normally closed, but can be opened at an appropriate time following a loss-of-coolant accident. When the valve opens, high-pressure gas inside the pneumatic tank is released to flow passively through the piping to pressurize the interior of the water-filled tank. In so doing, the initial water contents of the tank are expelled through the openings, causing the water level in the condenser pool to rise. This increases the volume of water available to be boiled off by heat conducted from the passive containment cooling heat exchangers. 4 figs.
NASA Astrophysics Data System (ADS)
Li, Yichen; Zhou, Lan; Liu, Guojin; Chai, Liqin; Fan, Qinguo; Shao, Jianzhong
2018-06-01
The Silica/Poly(methylmethacrylate-butylacrylate)[SiO2/P(MMA-BA)] photonic crystals(PCs) with brilliant structural colors were fabricated on fabric substrates by co-sedimentation self-assembly, in which the relatively smaller P(MMA-BA) copolymer particles filled in the interstices among the larger SiO2 microspheres. The fabricated composite PCs were mechanically robust and strongly bonded to the substrate because of the cementing effect caused by the soft P(MMA-BA) copolymer particles filling in the interstices of the SiO2 microspheres like cement filling in the gap and tightly holding stones in a sturdy cement wall. The volume fraction and the size ratios of the two components significantly influenced the structural colors of the composite PCs, and the larger volume fraction could improve the structural stability of the composite PCs, while the smaller size ratios could enhance the brightness of the structural colors of the composite PCs. The composite PCs with both high structural stability and brilliant structural colors have great application prospect for structural coloration of textiles.
Neural mechanisms of volume regulation.
DiBona, G F
1983-05-01
Under steady-state conditions, urinary sodium excretion matches dietary sodium intake. Because extracellular fluid osmolality is tightly regulated, the quantity of sodium in the extracellular fluid determines the volume of this compartment. The left atrial volume receptor mechanism is an example of a neural mechanism of volume regulation. The left atrial mechanoreceptor, which functions as a sensor in the low-pressure vascular system, has a well-defined compliance relating intravascular volume to filling pressure and responds to changes in wall tension by discharging into afferent vagal fibers. These fibers have appropriate central nervous system representation whose related efferent neurohumoral mechanisms regulate thirst, renal excretion of water and sodium, and the redistribution of the extracellular fluid volume.
Space filling minimal surfaces and sphere packings
NASA Astrophysics Data System (ADS)
Elser, Veit
1994-05-01
A space filling minimal surface is defined to be any embedded minimal surface without boundary with the property that the area and genus enclosed by any large spherical region scales in proportion to the volume of the region. The triply periodic minimal surfaces are one realization, but not necessarily the only one. By using the genus per unit volume of the surface, a meaningful comparison of surface areas can be made even in cases where there is no unit cell. Of the known periodic minimal surfaces this measure of the surface area is smallest for Schoen's FRD surface. This surface is one of several that is closely related to packings of spheres. Its low area is largely due to the fact that the corresponding sphere packing (fcc) has the maximal kissing number.
46 CFR 151.45-6 - Maximum amount of cargo.
Code of Federal Regulations, 2010 CFR
2010-10-01
... insulated, or 115 °F if uninsulated. If specific filling densities are designated in Subpart 151.50 of this...=Maximum volume to which tank may be loaded. V =Volume of tank. d r=Density of cargo at the temperature required for a cargo vapor pressure equal to the relief valve setting. d L=Density of cargo at the loading...
46 CFR 151.45-6 - Maximum amount of cargo.
Code of Federal Regulations, 2011 CFR
2011-10-01
... insulated, or 115 °F if uninsulated. If specific filling densities are designated in Subpart 151.50 of this...=Maximum volume to which tank may be loaded. V =Volume of tank. d r=Density of cargo at the temperature required for a cargo vapor pressure equal to the relief valve setting. d L=Density of cargo at the loading...
46 CFR 151.45-6 - Maximum amount of cargo.
Code of Federal Regulations, 2014 CFR
2014-10-01
... insulated, or 115 °F if uninsulated. If specific filling densities are designated in Subpart 151.50 of this...=Maximum volume to which tank may be loaded. V =Volume of tank. d r=Density of cargo at the temperature required for a cargo vapor pressure equal to the relief valve setting. d L=Density of cargo at the loading...
46 CFR 151.45-6 - Maximum amount of cargo.
Code of Federal Regulations, 2013 CFR
2013-10-01
... insulated, or 115 °F if uninsulated. If specific filling densities are designated in Subpart 151.50 of this...=Maximum volume to which tank may be loaded. V =Volume of tank. d r=Density of cargo at the temperature required for a cargo vapor pressure equal to the relief valve setting. d L=Density of cargo at the loading...
NASA Astrophysics Data System (ADS)
Atwood, Shane; Kankelborg, Charles C.
2017-08-01
The coronal volume is filled with magnetic field, yet only part of that volume has sufficient volume to exhibit hot X-ray loops. Using XRT and AIA images, we identify footpoints of hot coronal loops. We then use IRIS rasters to compare the spatial, temporal, and spectral structure of these relatively "heated" and "unheated" regions. We seek a signature of upward-propagating energy that could be associated with hot active region loops.
ECO fill: automated fill modification to support late-stage design changes
NASA Astrophysics Data System (ADS)
Davis, Greg; Wilson, Jeff; Yu, J. J.; Chiu, Anderson; Chuang, Yao-Jen; Yang, Ricky
2014-03-01
One of the most critical factors in achieving a positive return for a design is ensuring the design not only meets performance specifications, but also produces sufficient yield to meet the market demand. The goal of design for manufacturability (DFM) technology is to enable designers to address manufacturing requirements during the design process. While new cell-based, DP-aware, and net-aware fill technologies have emerged to provide the designer with automated fill engines that support these new fill requirements, design changes that arrive late in the tapeout process (as engineering change orders, or ECOs) can have a disproportionate effect on tapeout schedules, due to the complexity of replacing fill. If not handled effectively, the impacts on file size, run time, and timing closure can significantly extend the tapeout process. In this paper, the authors examine changes to design flow methodology, supported by new fill technology, that enable efficient, fast, and accurate adjustments to metal fill late in the design process. We present an ECO fill methodology coupled with the support of advanced fill tools that can quickly locate the portion of the design affected by the change, remove and replace only the fill in that area, while maintaining the fill hierarchy. This new fill approach effectively reduces run time, contains fill file size, minimizes timing impact, and minimizes mask costs due to ECO-driven fill changes, all of which are critical factors to ensuring time-to-market schedules are maintained.
Shekhawat, Nakul S; Shtein, Roni M; Blachley, Taylor S; Stein, Joshua D
2017-08-01
Antibiotics are seldom necessary to treat acute conjunctivitis. We assessed how frequently patients with newly diagnosed acute conjunctivitis fill prescriptions for topical antibiotics and factors associated with antibiotic prescription fills. Retrospective, observational cohort study. A total of 340 372 enrollees in a large nationwide United States managed care network with newly diagnosed acute conjunctivitis, from 2001 through 2014. We identified all enrollees newly diagnosed with acute conjunctivitis, calculating the proportion filling 1 or more topical antibiotic prescription within 14 days of initial diagnosis. Multivariate logistic regression assessed sociodemographic, medical, and other factors associated with antibiotic prescription fills for acute conjunctivitis. Geographic variation in prescription fills also was studied. Odds ratios (ORs) with 95% confidence intervals (CIs) for filling an antibiotic prescription for acute conjunctivitis. Among 340 372 enrollees with acute conjunctivitis, 198 462 (58%) filled ≥1 topical antibiotic prescriptions; 38 774 filled prescriptions for antibiotic-corticosteroid combination products. Compared with whites, blacks (OR, 0.89; 95% CI, 0.86-0.92) and Latinos (OR, 0.83; 95% CI, 0.81-0.86) had lower odds of filling antibiotic prescriptions. More affluent and educated enrollees had higher odds of filling antibiotic prescriptions compared with those with lesser affluence and education (P < 0.01 for all). Compared with persons initially diagnosed with acute conjunctivitis by ophthalmologists, enrollees had considerably higher odds of antibiotic prescription fills if first diagnosed by an optometrist (OR, 1.26; 95% CI, 1.21-1.31), urgent care physician (OR, 3.29; 95% CI, 3.17-3.41), internist (OR, 2.79; 95% CI, 2.69-2.90), pediatrician (OR, 2.27; 95% CI, 2.13-2.43), or family practitioner (OR, 2.46; 95% CI, 2.37-2.55). Antibiotic prescription fills did not differ for persons with versus without risk factors for development of serious infections, such as contact lens wearers (P = 0.21) or patients with human immunodeficiency virus infection or AIDS (P = 0.60). Nearly 60% of enrollees in this managed care network filled antibiotic prescriptions for acute conjunctivitis, and 1 of every 5 antibiotic users filled prescriptions for antibiotic-corticosteroids, which are contraindicated for acute conjunctivitis. These potentially harmful practices may prolong infection duration, may promote antibiotic resistance, and increase costs. Filling antibiotic prescriptions seems to be driven more by sociodemographic factors and type of provider diagnosing the enrollee than by medical indication. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Fukui, Yasuo; Hayakawa, Takahiro; Inoue, Tsuyoshi; Torii, Kazufumi; Okamoto, Ryuji; Tachihara, Kengo; Onishi, Toshikazu; Hayashi, Katsuhiro
2018-06-01
We carried out synthetic observations of interstellar atomic hydrogen at 21 cm wavelength by utilizing the magnetohydrodynamic numerical simulations of the inhomogeneous turbulent interstellar medium. The cold neutral medium (CNM) shows a significantly clumpy distribution with a small volume filling factor of 3.5%, whereas the warm neutral medium (WNM) has a distinctly different and smooth distribution with a large filling factor of 96.5%. In projection on the sky, the CNM exhibits a highly filamentary distribution with a subparsec width, whereas the WNM shows a smooth, extended distribution. In the H I optical depth, the CNM is dominant and the contribution of the WNM is negligibly small. The CNM has an area covering factor of 30% in projection, while the WNM has a covering factor of 70%. This means that the emission–absorption measurements toward radio continuum compact sources tend to sample the WNM with a probability of 70%, yielding a smaller H I optical depth and a smaller H I column density than those of the bulk H I gas. The emission–absorption measurements, which are significantly affected by the small-scale large fluctuations of the CNM properties, are not suitable for characterizing the bulk H I gas. Larger-beam emission measurements that are able to fully sample the H I gas will provide a better tool for that purpose, if a reliable proxy for hydrogen column density, possibly dust optical depth and gamma rays, is available. The present results provide a step toward precise measurements of the interstellar hydrogen with ∼10% accuracy. This will be crucial in interstellar physics, including identification of the proton–proton interaction in gamma-ray supernova remnants.
Shetty, Saurabha; Majumder, Dipanjan; Adurkar, Pranjal; Swamidas, Jamema; Engineer, Reena; Chopra, Supriya; Shrivastava, Shyamkishore
2017-01-01
Purpose The aim of this study is to compare 3D dose volume histogram (DVH) parameters of bladder and other organs at risk with different bladder filling protocol during high-dose-rate intracavitary brachytherapy (HDR-ICBT) in cervical cancer, and to find optimized bladder volume. Material and methods This dosimetric study was completed with 21 patients who underwent HDR-ICBT with computed tomography/magnetic resonance compatible applicator as a routine treatment. Computed tomography planning was done for each patient with bladder emptied (series 1), after 50 ml (series 2), and 100 ml (series 3) bladder filling with a saline infusion through the bladder catheter. Contouring was done on the Eclipse Planning System. 7 Gy to point A was prescribed with the standard loading patterns. Various 3D DVH parameters including 0.1 cc, 1 cc, 2 cc doses and mean doses to the OAR’s were noted. Paired t-test was performed. Results The mean (± SD) bladder volume was 64.5 (± 25) cc, 116.2 (± 28) cc, and 172.9 (± 29) cc, for series 1, 2, and 3, respectively. The 0.1 cm3,1 cm3, 2 cm3 mean bladder doses for series 1, series 2, and series 3 were 9.28 ± 2.27 Gy, 7.38 ± 1.72 Gy, 6.58 ± 1.58 Gy; 9.39 ± 2.28 Gy, 7.85 ± 1.85 Gy, 7.05 ± 1.59 Gy, and 10.09 ± 2.46 Gy, 8.33 ± 1.75 Gy, 7.6 ± 1.55 Gy, respectively. However, there was a trend towards higher bladder doses in series 3. Similarly, for small bowel dose 0.1 cm3, 1 cm3, and 2 cm3 in series 1, 2, and 3 were 5.44 ± 2.2 Gy, 4.41 ± 1.84 Gy, 4 ± 1.69 Gy; 4.57 ± 2.89 Gy, 3.78 ± 2.21 Gy, 3.35 ± 2.02 Gy, and 4.09 ± 2.38 Gy, 3.26 ± 1.8 Gy, 3.05 ± 1.58 Gy. Significant increase in small bowel dose in empty bladder (series 1) compared to full bladder (series 3) (p = 0.03) was noted. However, the rectal and sigmoid doses were not significantly affected with either series. Conclusions Bladder filling protocol with 50 ml and 100 ml was well tolerated and achieved a reasonably reproducible bladder volume during cervical brachytherapy. In our analysis so far, there is no significant impact of bladder filling on DVH parameters, although larger bladders tend to have higher doses. Small bowel doses are lesser with higher bladder volumes. Further evaluation and validation are necessary. PMID:28533798
Music-listening habits with MP3 player in a group of adolescents: a descriptive survey.
Pellegrino, E; Lorini, C; Allodi, G; Buonamici, C; Garofalo, G; Bonaccorsi, G
2013-01-01
Listening to music through portable MP3 players has become a very popular mode among young people and adolescents. The aim of this study is to investigate the behaviors of adolescents engaged in listening to music with MP3 player and the attendance at clubs (pubs, discotheques) where music is played at high volume. Among the 1470 students attending a secondary school in Scandicci (FI) during the school year 2009/2010, 1278 (86.9%) were at school the day of the examination and 1276 completely filled in the questionnaire. Descriptive analysis and univariate and multivariate logistic regression were performed to calculate the degree of association (OR) among the sociodemographic characteristics, listening habits and some factors identified as risky or protective as regards the possibility of developing health disorders. MP3 player users are 88.2% of the sample. Among these, a high proportion engaged behaviours that increase the risk of presenting disorders, including the exposure to high-volume (27.4%). Furthermore, 44.6% use the MP3 while driving. From the regression analysis it emerges that MP3 users showed a sort of addiction: by increasing the time and the occasions of exposure to music, they increased the volume, used maximum or medium-high volume, did not take breaks and did not decrease the volume. The study points out the spread of risky behavior in music listening, so it is necessary to better inform especially the youngsters and achieve specific preventive interventions.
Effect of masking phase-only holograms on the quality of reconstructed images.
Deng, Yuanbo; Chu, Daping
2016-04-20
A phase-only hologram modulates the phase of the incident light and diffracts it efficiently with low energy loss because of the minimum absorption. Much research attention has been focused on how to generate phase-only holograms, and little work has been done to understand the effect and limitation of their partial implementation, possibly due to physical defects and constraints, in particular as in the practical situations where a phase-only hologram is confined or needs to be sliced or tiled. The present study simulates the effect of masking phase-only holograms on the quality of reconstructed images in three different scenarios with different filling factors, filling positions, and illumination intensity profiles. Quantitative analysis confirms that the width of the image point spread function becomes wider and the image quality decreases, as expected, when the filling factor decreases, and the image quality remains the same for different filling positions as well. The width of the image point spread function as derived from different filling factors shows a consistent behavior to that as measured directly from the reconstructed image, especially as the filling factor becomes small. Finally, mask profiles of different shapes and intensity distributions are shown to have more complicated effects on the image point spread function, which in turn affects the quality and textures of the reconstructed image.
Hernández-Pérez, María; Puig, Josep; Blasco, Gerard; Pérez de la Ossa, Natalia; Dorado, Laura; Dávalos, Antoni; Munuera, Josep
2016-02-01
Contrary to usual static vascular imaging techniques, contrast-enhanced dynamic magnetic resonance angiography (dMRA) enables dynamic study of cerebral vessels. We evaluated dMRA ability to assess arterial occlusion, cerebral hemodynamics, and collateral circulation in acute ischemic stroke. Twenty-five acute ischemic stroke patients with proximal anterior circulation occlusion underwent dMRA on a 3T scanner within 12 hours of symptoms onset. Diffusion weighted imaging, Tmax6 s lesion volumes and hypoperfusion intensity ratio as volume of Tmax>6 s/volume of Tmax>10 s were measured. Site and grade of occlusion (Thrombolysis in Myocardial Infarction criteria) were evaluated on time-of-flight MRA and dMRA. Leptomeningeal collaterality (American Society of Interventional and Therapeutic Neuroradiology/Society of Interventional Radiology [ASITN/SIR] Scale) and asymmetries in venous clearance were assessed exclusively on dMRA. Collateral filling was dichotomized into incomplete (ASITN/SIR 0-2) or complete (ASITN/SIR 3-4). On dMRA, site of occlusion was M1 in 21 patients, tandem internal carotid artery/M1 in 2 and tandem internal carotid artery/terminal internal carotid artery in 2 patients. Three tandem occlusions were not detected on time-of-flight-MRA. All patients had Thrombolysis in Myocardial Infarction 0 to 1 on time-of-flight-MRA, but three of them had Thrombolysis in Myocardial Infarction 2 on dMRA. Complete collateral filling (n=12, 48%) was associated with smaller diffusion weighted imaging lesion volume (P=0.039), smaller hypoperfused volume (P=0.018), and lower hypoperfusion intensity ratio (P=0.006). Patients with symmetrical clearance of transverse sinuses (52%) were more likely to have complete collateral filling (P=0.015). As a fast, direct, feasible, noninvasive, and reliable method to assess site of occlusion, collateral circulation and hemodynamic alterations, dMRA provides profound insights in acute stroke. © 2015 American Heart Association, Inc.
Pore-scale supercritical CO 2 dissolution and mass transfer under drainage conditions
Chang, Chun; Zhou, Quanlin; Oostrom, Mart; ...
2016-12-05
Recently, both core- and pore-scale imbibition experiments have shown non-equilibrium dissolution of supercritical CO 2 (scCO 2) and a prolonged depletion of residual scCO 2. In this paper, pore-scale scCO 2 dissolution and mass transfer under drainage conditions were investigated using a two-dimensional heterogeneous micromodel and a novel fluorescent water dye with a sensitive pH range between 3.7 and 6.5. Drainage experiments were conducted at 9 MPa and 40 °C by injecting scCO 2 into the sandstone-analogue pore network initially saturated by water without dissolved CO 2 (dsCO 2). During the experiments, time-lapse images of dye intensity, reflecting water pH,more » were obtained. These images show non-uniform pH in individual pores and pore clusters, with average pH levels gradually decreasing with time. Further analysis on selected pores and pore clusters shows that (1) rate-limited mass transfer prevails with slowly decreasing pH over time when the scCO 2-water interface area is low with respect to the volume of water-filled pores and pore clusters, (2) fast scCO 2 dissolution and phase equilibrium occurs when scCO 2 bubbles invade into water-filled pores, significantly enhancing the area-to-volume ratio, and (3) a transition from rate-limited to diffusion-limited mass transfer occurs in a single pore when a medium area-to-volume ratio is prevalent. The analysis also shows that two fundamental processes – scCO 2 dissolution at phase interfaces and diffusion of dsCO 2 at the pore scale (10–100 µm) observed after scCO 2 bubble invasion into water-filled pores without pore throat constraints – are relatively fast. The overall slow dissolution of scCO 2 in the millimeter-scale micromodel can be attributed to the small area-to-volume ratios that represent pore-throat configurations and characteristics of phase interfaces. Finally, this finding is applicable for the behavior of dissolution at pore, core, and field scales when water-filled pores and pore clusters of varying size are surrounded by scCO 2 at narrow pore throats.« less
Pore-scale supercritical CO 2 dissolution and mass transfer under drainage conditions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, Chun; Zhou, Quanlin; Oostrom, Mart
Recently, both core- and pore-scale imbibition experiments have shown non-equilibrium dissolution of supercritical CO 2 (scCO 2) and a prolonged depletion of residual scCO 2. In this paper, pore-scale scCO 2 dissolution and mass transfer under drainage conditions were investigated using a two-dimensional heterogeneous micromodel and a novel fluorescent water dye with a sensitive pH range between 3.7 and 6.5. Drainage experiments were conducted at 9 MPa and 40 °C by injecting scCO 2 into the sandstone-analogue pore network initially saturated by water without dissolved CO 2 (dsCO 2). During the experiments, time-lapse images of dye intensity, reflecting water pH,more » were obtained. These images show non-uniform pH in individual pores and pore clusters, with average pH levels gradually decreasing with time. Further analysis on selected pores and pore clusters shows that (1) rate-limited mass transfer prevails with slowly decreasing pH over time when the scCO 2-water interface area is low with respect to the volume of water-filled pores and pore clusters, (2) fast scCO 2 dissolution and phase equilibrium occurs when scCO 2 bubbles invade into water-filled pores, significantly enhancing the area-to-volume ratio, and (3) a transition from rate-limited to diffusion-limited mass transfer occurs in a single pore when a medium area-to-volume ratio is prevalent. The analysis also shows that two fundamental processes – scCO 2 dissolution at phase interfaces and diffusion of dsCO 2 at the pore scale (10–100 µm) observed after scCO 2 bubble invasion into water-filled pores without pore throat constraints – are relatively fast. The overall slow dissolution of scCO 2 in the millimeter-scale micromodel can be attributed to the small area-to-volume ratios that represent pore-throat configurations and characteristics of phase interfaces. Finally, this finding is applicable for the behavior of dissolution at pore, core, and field scales when water-filled pores and pore clusters of varying size are surrounded by scCO 2 at narrow pore throats.« less
Pore-scale supercritical CO 2 dissolution and mass transfer under drainage conditions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, Chun; Zhou, Quanlin; Oostrom, Mart
Abstract: Recently, both core- and pore-scale imbibition experiments have shown non-equilibrium dissolution of supercritical CO 2 (scCO 2) and a prolonged depletion of residual scCO 2. In this study, pore-scale scCO 2 dissolution and mass transfer under drainage conditions were investigated using a two-dimensional heterogeneous micromodel and a novel fluorescent water dye with a sensitive pH range between 3.7 and 6.5. Drainage experiments were conducted at 9 MPa and 40 °C by injecting scCO 2 into the sandstone-analogue pore network initially saturated by water without dissolved CO 2 (dsCO 2). During the experiments, time-lapse images of dye intensity, reflecting watermore » pH, were obtained. These images show non-uniform pH in individual pores and pore clusters, with average pH levels gradually decreasing with time. Further analysis on selected pores and pore clusters shows that (1) rate-limited mass transfer prevails with slowly decreasing pH over time when the scCO 2-water interface area is low with respect to the volume of water-filled pores and pore clusters, (2) fast scCO 2 dissolution and phase equilibrium occurs when scCO 2 bubbles invade into water-filled pores, significantly enhancing the area-to-volume ratio, and (3) a transition from rate-limited to diffusion-limited mass transfer occurs in a single pore when a medium area-to-volume ratio is prevalent. The analysis also shows that two fundamental processes – scCO 2 dissolution at phase interfaces and diffusion of dsCO 2 at the pore scale (10-100 µm) observed after scCO 2 bubble invasion into water-filled pores without pore throat constraints – are relatively fast. The overall slow dissolution of scCO 2 in the millimeter-scale micromodel can be attributed to the small area-to-volume ratios that represent pore-throat configurations and characteristics of phase interfaces. This finding is applicable for the behavior of dissolution at pore, core, and field scales when water-filled pores and pore clusters of varying size are surrounded by scCO 2 at narrow pore throats.« less
Peeters, Elisabeth; De Beer, Thomas; Vervaet, Chris; Remon, Jean-Paul
2015-04-01
Tableting is a complex process due to the large number of process parameters that can be varied. Knowledge and understanding of the influence of these parameters on the final product quality is of great importance for the industry, allowing economic efficiency and parametric release. The aim of this study was to investigate the influence of paddle speeds and fill depth at different tableting speeds on the weight and weight variability of tablets. Two excipients possessing different flow behavior, microcrystalline cellulose (MCC) and dibasic calcium phosphate dihydrate (DCP), were selected as model powders. Tablets were manufactured via a high-speed rotary tablet press using design of experiments (DoE). During each experiment also the volume of powder in the forced feeder was measured. Analysis of the DoE revealed that paddle speeds are of minor importance for tablet weight but significantly affect volume of powder inside the feeder in case of powders with excellent flowability (DCP). The opposite effect of paddle speed was observed for fairly flowing powders (MCC). Tableting speed played a role in weight and weight variability, whereas changing fill depth exclusively influenced tablet weight. The DoE approach allowed predicting the optimum combination of process parameters leading to minimum tablet weight variability. Monte Carlo simulations allowed assessing the probability to exceed the acceptable response limits if factor settings were varied around their optimum. This multi-dimensional combination and interaction of input variables leading to response criteria with acceptable probability reflected the design space.
Schneider, Caroline; Forsythe, Lynsey; Somauroo, John; George, Keith; Oxborough, David
2018-01-03
Left ventricular (LV) function is dependent on load, intrinsic contractility and relaxation with a variable impact on specific mechanics. Strain (ε) imaging allows the assessment of cardiac function however the direct relationship between volume and strain is currently unknown. The aim of this study was to establish the impact of preload reduction through head-up tilt (HUT) testing on simultaneous left ventricular (LV) longitudinal and transverse function and their respective contribution to volume change. A focused transthoracic echocardiogram was performed on 10 healthy male participants (23 ± 3 years,) in the supine position and following 1 min and 5 min of HUT testing. Raw temporal longitudinal ε (Ls) and transverse ε (Ts) values were exported and divided into 5% increments across the cardiac cycle and corresponding LV volumes were traced at each 5% increment. This provided simultaneous LV longitudinal and transverse ε and volume-loops (deformation-volume analysis - DVA). There was a leftward- shift of the ε -volume loop from supine to 1 min and 5 min of HUT, p<0.001). Moreover, longitudinal shortening was reduced (p<0.001) with a concomitant increase in transverse thickening from supine to 1min, which was further augmented at 5min (p=0.018). Preload reduction occurs within 1 minute of HUT but does not further reduce at 5 minutes. This decline is associated with a decrease in longitudinal ε and concomitant increase in transverse ε. Consequently, augmented transverse relaxation appears to be an important factor in the maintenance of LV filling in the setting of reduced preload. DVA provides information on the relative contribution of mechanics to a change in LV volume and may have a role in the assessment of clinical populations. © 2018 The authors.
The volume of fine sediment in pools: An index of sediment supply in gravel-bed streams
Thomas E. Lisle; Sue Hilton
1992-01-01
Abstract - During waning flood flows in gravel-bed streams, fine-grained bedload sediment (sand and fine gravel) is commonly winnowed from zones of high shear stress, such as riffles, and deposited in pools, where it mantles an underlying coarse layer. As sediment load increases, more fine sediment becomes availabe to fill pools. The volume of fine sediment in pools...
Using Dalton's Law of Partial Pressures to Determine the Vapor Pressure of a Volatile Liquid
ERIC Educational Resources Information Center
Hilgeman, Fred R.; Bertrand, Gary; Wilson, Brent
2007-01-01
This experiment, designed for a general chemistry laboratory, illustrates the use of Dalton's law of partial pressures to determine the vapor pressure of a volatile liquid. A predetermined volume of air is injected into a calibrated tube filled with a liquid whose vapor pressure is to be measured. The volume of the liquid displaced is greater than…
Nobile, Vincenzo; Buonocore, Daniela; Michelotti, Angela; Marzatico, Fulvio
2014-12-01
Human skin aging is a multifactorial and complex biological process affecting the different skin constituents. Even if the skin aging mechanism is not yet fully unravelled is evident that epidermis loses the principal molecule responsible for binding and retaining water molecules, resulting in loss of skin moisture and accounting for some of the most striking alterations of the aged skin. This Study investigated the cosmetic filling efficacy of Fillerina® in decreasing the skin aging signs and in improving facial volume deficiencies. A placebo-controlled, double-blind, randomized clinical trial was carried out on 40 healthy female subjects showing mild to moderate clinical signs of skin aging. The effect of the treatment on skin surface and on face volumes was assessed both in the short-term (3 h after a single product application) and in the long-term (7, 14, and 30 days after continuative daily use). Three hours after a single application and after 7, 14, and 30 days of treatment the lips volume was increased by 8.5%, 11.3%, 12.8%, and 14.2%. After 7, 14, and 30 days: (1) skin sagging of the face contours was decreased by -0.443 ± 0.286, -1.124 ± 0.511, and -1.326 ± 0.649 mm, respectively; (2) skin sagging of the cheekbones contours was decreased by -0.989 ± 0.585, -2.500 ± 0.929, and -2.517 ± 0.927 mm, respectively; (3) cheekbones volume was increased by 0.875 ± 0.519, 2.186 ± 0.781, and 2.275 ± 0.725 mm, respectively; (4) wrinkle volume was decreased by -11.3%, -18.4%, and -26.3%, respectively; and (5) wrinkle depth was decreased by -8.4%, -14.5%, and -21.8% respectively. This study demonstrated the positive filling effect of Fillerina® in decreasing the clinical signs of skin aging and in improving the face volumes. © 2014 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Tack, Gye Rae; Choi, Hyung Guen; Shin, Kyu-Chul; Lee, Sung J.
2001-06-01
Percutaneous vertebroplasty is a surgical procedure that was introduced for the treatment of compression fracture of the vertebrae. This procedure includes puncturing vertebrae and filling with polymethylmethacrylate (PMMA). Recent studies have shown that the procedure could provide structural reinforcement for the osteoporotic vertebrae while being minimally invasive and safe with immediate pain relief. However, treatment failures due to disproportionate PMMA volume injection have been reported as one of complications in vertebroplasty. It is believed that control of PMMA volume is one of the most critical factors that can reduce the incidence of complications. In this study, appropriate amount of PMMA volume was assessed based on the imaging data of a given patient under the following hypotheses: (1) a relationship can be drawn between the volume of PMMA injection and textural features of the trabecular bone in preoperative CT images and (2) the volume of PMMA injection can be estimated based on 3D reconstruction of postoperative CT images. Gray-level run length analysis was used to determine the textural features of the trabecular bone. The width of trabecular (T-texture) and the width of intertrabecular spaces (I-texture) were calculated. The correlation between PMMA volume and textural features of patient's CT images was also examined to evaluate the appropriate PMMA amount. Results indicated that there was a strong correlation between the actual PMMA injection volume and the area of the intertrabecular space and that of trabecular bone calculated from the CT image (correlation coefficient, requals0.96 and requals-0.95, respectively). T- texture (requals-0.93) did correlate better with the actual PMMA volume more than the I-texture (requals0.57). Therefore, it was demonstrated that appropriate PMMA injection volume could be predicted based on the textural analysis for better clinical management of the osteoporotic spine.
Hartmann, A; Maul, F D; Zimny, M; Klepzig, H; Vallbracht, C; Kneissl, H G; Schräder, R; Hör, G; Kaltenbach, M
1991-09-01
Impairment of left ventricular function during controlled myocardial ischemia induced by coronary angioplasty has been reported from angiographic and echocardiographic studies. Ejection fraction, peak ejection, peak filling rates, and end-systolic and end-diastolic volumes were investigated before, during and after coronary occlusion on-line with a nonimaging scintillation probe. The study consisted of 18 patients (mean age 59 +/- 10 years) with coronary artery stenosis of greater than 70%. During balloon inflation of 60 seconds' duration, coronary occlusion pressure was 31.6 +/- 12 mm Hg. There was no significant change in heart rate. Delay between first and second dilatation was 109 +/- 63 seconds. Ejection fraction decreased from 53 +/- 16 to 40 +/- 12% (first dilatation, p less than 0.01) and to 39 +/- 14% (second dilatation, p less than 0.01) and recovered to 51 +/- 16% 5 minutes after the second dilatation. Peak ejection rate was significantly reduced during the first and second balloon inflations. Peak filling rate decreased from 2.5 +/- 0.8 to 2.0 +/- 0.7 end-diastolic volume.s-1 (first dilatation, p less than 0.01) and to 1.8 +/- 0.7 end-diastolic volume.s-1 (second dilatation, p less than 0.01) and remained reduced at 2.2 +/- 0.7 end-diastolic volume.s-1 (p = not significant) at 5 minutes after the second dilatation. End-systolic and end-diastolic volumes increased significantly during the first and second dilatations and returned to normal after dilatation. It is concluded that short, controlled myocardial ischemia during coronary angioplasty leads to a decrease in systolic and diastolic left ventricular function. Sequential dilatations do not further decrease function if a sufficient interval is kept.
33 CFR 159.103 - Vibration test.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., with liquid retention components, if any, filled with water to one-half of their volume, must be... the resonant frequency of the device (or at 55 cycles per second if there is no resonant frequency...
33 CFR 159.103 - Vibration test.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., with liquid retention components, if any, filled with water to one-half of their volume, must be... the resonant frequency of the device (or at 55 cycles per second if there is no resonant frequency...
33 CFR 159.103 - Vibration test.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., with liquid retention components, if any, filled with water to one-half of their volume, must be... the resonant frequency of the device (or at 55 cycles per second if there is no resonant frequency...
33 CFR 159.103 - Vibration test.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., with liquid retention components, if any, filled with water to one-half of their volume, must be... the resonant frequency of the device (or at 55 cycles per second if there is no resonant frequency...
Code of Federal Regulations, 2010 CFR
2010-07-01
... MARINE SANITATION DEVICES Design, Construction, and Testing § 159.105 Shock test. The device, with liquid retention components, if any, filled with water to half of their volume, must be subjected to 1,000 vertical...
NASA Technical Reports Server (NTRS)
Clayton, J. Louie
2002-01-01
This study provides development and verification of analysis methods used to assess performance of a carbon fiber rope (CFR) thermal barrier system that is currently being qualified for use in Reusable Solid Rocket Motor (RSRM) nozzle joint-2. Modeled geometry for flow calculations considers the joint to be vented with the porous CFR barriers placed in the 'open' assembly gap. Model development is based on a 1-D volume filling approach where flow resistances (assembly gap and CFRs) are defined by serially connected internal flow and the porous media 'Darcy' relationships. Combustion gas flow rates are computed using the volume filling code by assuming a lumped distribution total joint fill volume on a per linear circumferential inch basis. Gas compressibility, friction and heat transfer are included in the modeling. Gas-to-wall heat transfer is simulated by concurrent solution of the compressible flow equations and a large thermal 2-D finite element (FE) conduction grid. The derived numerical technique loosely couples the FE conduction matrix with the compressible gas flow equations. Free constants that appear in the governing equations are calibrated by parametric model comparison to hot fire subscale test results. The calibrated model is then used to make full-scale motor predictions using RSRM aft dome environments. Model results indicate that CFR thermal barrier systems will provide a thermally benign and controlled pressurization environment for the RSRM nozzle joint-2 primary seal activation.
NASA Technical Reports Server (NTRS)
Clayton, J. Louie; Phelps, Lisa (Technical Monitor)
2001-01-01
This study provides for development and verification of analysis methods used to assess performance of a carbon fiber rope (CFR) thermal barrier system that is currently being qualified for use in Reusable Solid Rocket Motor (RSRM) nozzle joint-2. Modeled geometry for flow calculations considers the joint to be vented with the porous CFR barriers placed in the "open' assembly gap. Model development is based on a 1-D volume filling approach where flow resistances (assembly gap and CFRs) are defined by serially connected internal flow and the porous media "Darcy" relationships. Combustion gas flow rates are computed using the volume filling code by assuming a lumped distribution total joint fill volume on a per linear circumferential inch basis. Gas compressibility, friction and heat transfer are included in the modeling. Gas-to-wall heat transfer is simulated by concurrent solution of the compressible flow equations and a large thermal 2-D finite element (FE) conduction grid. The derived numerical technique loosely couples the FE conduction matrix with the compressible gas flow equations, Free constants that appear in the governing equations are calibrated by parametric model comparison to hot fire subscale test results. The calibrated model is then used to make full-scale motor predictions using RSRM aft dome environments. Model results indicate that CFR thermal barrier systems will provide a thermally benign and controlled pressurization environment for the RSRM nozzle joint-2 primary seal activation.
Craggs, Michael D
2005-09-01
Detrusor overactivity is the primary objective focus of most investigations into the diagnosis and management of patients with urgency incontinence. Patients with an overactive bladder are characteristically troubled by subjective sensations of bladder fullness and urinary urgency, and frequently void at low bladder volumes attained before noticeable detrusor overactivity occurs. Bladder sensations are therefore crucial to understanding voiding patterns and symptoms, but little progress has been made in objectively describing the range of these sensations, and adequate information is lacking about their response to neuromodulation. Towards this end, a keypad 'urge score' device was designed to measure sensations during bladder filling. This patient-activated device gathers information about patient perceptions of bladder filling and the successive stages of increasing bladder sensation, without prompting or intervention by the investigator. The accuracy of the 'urge keypad' during filling cystometrography was validated in patients with urgency incontinence, and compared with data abstracted from patient voiding diaries. The device provides reliable and repeatable measures of different bladder sensations, with excellent, statistically significant consistency between bladder volumes and corresponding levels of sensation. Subsequently, it was shown that the sensation of urgency can be suppressed by neuromodulation in most patients tested; this suppression occurs with improvements in bladder capacity and voided volumes. It is therefore suggested that urodynamics with concurrent sensory evaluation may offer a more useful assessment tool for selecting those patients for therapies such as neuromodulation who present predominantly with the symptom of urgency.
2013-06-01
outer bank threatened a Fed- eral levee that protects adjacent homes and farmland. The eroded chute bank approached the toe of the levee causing...design drawing for repairing the levee toe . Approximately 30,000 tons of riprap were placed to re-establish the bank in front of the scour hole...Sediment was needed to fill and stabilize the scour hole between the riprap bank and the toe of the levee. The volume required to fill the scour hole
Bucuta, Stefan; Ilie, Nicoleta
2014-11-01
The aim of this study was to quantify the blue light that passes through different incremental thicknesses of bulk fill in comparison to conventional resin-based composites (RBCs) and to relate it to the induced mechanical properties. Seven bulk fill, five nanohybrid and two flowable RBCs were analysed. Specimens (n = 5) of three incremental thicknesses (2, 4 and 6 mm) were cured from the top for 20 s, while at the bottom, a spectrometer monitored in real time the transmitted irradiance. Micro-mechanical properties (Vickers hardness, HV, and indentation modulus, E) were measured at the top and bottom after 24 h of storage in distilled water at 37 °C. Electron microscope images were taken for assessing the filler distribution and size. Bulk fill RBCs (except SonicFill) were more translucent than conventional RBCs. Low-viscosity bulk fill materials showed the lowest mechanical properties. HV depends highly on the following parameters: material (ηp (2) = 0.952), incremental thickness (0.826), filler volume (0.747), filler weight (0.746) and transmitted irradiance (0.491). The bottom-to-top HV ratio (HVbt) was higher than 80 % in all materials in 2- and 4-mm increments (except for Premise), whereas in 6-mm increments, this is valid only in four bulk fill materials (Venus Bulk Fill, SDR, x-tra fil, Tetric EvoCeram Bulk Fill). The depth of cure is dependent on the RBC's translucency. Low-viscosity bulk fill RBCs have lower mechanical properties than all other types of analysed materials. All bulk fill RBCs (except SonicFill) are more translucent for blue light than conventional RBCs. Although bulk fill RBCs are generally more translucent, the practitioner has to follow the manufacturer's recommendations on curing technique and maximum incremental thickness.
NASA Astrophysics Data System (ADS)
Carpenter, Corinne L.; Delaney, Kris T.; Laachi, Nabil; Fredrickson, Glenn H.
2015-03-01
Directed self-assembly (DSA) of block copolymers has attracted attention for its use as a simple, cost- effective patterning tool for creating vertical interconnect access (VIA) channels in nanoelectronic devices.1, 2 This technique supplements existing lithographic technologies to allow for the creation of high-resolution cylindrical holes whose diameter and placement can be precisely controlled. In this study, we use self-consistent field theory (SCFT) simulations to investigate the equilibrium configurations of under-filled DSA systems with air-polymer interactions. We report on a series of SCFT simulations of our three species (PMMA-b-PS diblock and air) model in cylindrical confinement to explore the role of template diameter, under-fill fraction (i.e. volume fraction of air), air-polymer surface interaction and polymer-side wall/substrate interactions on equilibrium morphologies in an under-filled template with a free top surface. We identify parameters and system configurations where a meniscus appears and explore cases with PMMA-attractive, PS-attractive, and all-neutral walls to understand the effects of wall properties on meniscus geometry and DSA morphology. An important outcome is an understanding of the parameters that control the contact angle of the meniscus with the wall, as it is one of the simplest quantitative measures of the meniscus shape. Ultimately, we seek to identify DSA formulations, templates, and surface treatments with predictable central cylinder diameter and a shallow contact angle, as these factors would facilitate broad process windows and ease of manufacturing.
Mean circulatory filling pressure: its meaning and measurement.
Rothe, C F
1993-02-01
The volume-pressure relationship of the vasculature of the body as a whole, its vascular capacitance, requires a measurement of the mean circulatory filling pressure (Pmcf). A change in vascular capacitance induced by reflexes, hormones, or drugs has physiological consequences similar to a rapid change in blood volume and thus strongly influences cardiac output. The Pmcf is defined as the mean vascular pressure that exists after a stop in cardiac output and redistribution of blood, so that all pressures are the same throughout the system. The Pmcf is thus related to the fullness of the circulatory system. A change in Pmcf provides a uniquely useful index of a change in overall venous smooth muscle tone if the blood volume is not concomitantly changed. The Pmcf also provides an estimate of the distending pressure in the small veins and venules, which contain most of the blood in the body and comprise most of the vascular compliance. Thus the Pmcf, which is normally independent of the magnitude of the cardiac output, provides an estimate of the upstream pressure that determines the rate of flow returning to the heart.
Dissolved solids in basin-fill aquifers and streams in the southwestern United States
Anning, David W.; Bauch, Nancy J.; Gerner, Steven J.; Flynn, Marilyn E.; Hamlin, Scott N.; Moore, Stephanie J.; Schaefer, Donald H.; Anderholm, Scott K.; Spangler, Lawrence E.
2007-01-01
The U.S. Geological Survey National Water-Quality Assessment Program performed a regional study in the Southwestern United States (Southwest) to describe the status and trends of dissolved solids in basin-fill aquifers and streams and to determine the natural and human factors that affect dissolved solids. Basin-fill aquifers, which include the Rio Grande aquifer system, Basin and Range basin-fill aquifers, and California Coastal Basin aquifers, are the most extensively used ground-water supplies in the Southwest. Rivers, such as the Colorado, the Rio Grande, and their tributaries, are also important water supplies, as are several smaller river systems that drain internally within the Southwest, or drain externally to the Pacific Ocean in southern California. The study included four components that characterize (1) the spatial distribution of dissolved-solids concentrations in basin-fill aquifers, and dissolved-solids concentrations, loads, and yields in streams; (2) natural and human factors that affect dissolved-solids concentrations; (3) major sources and areas of accumulation of dissolved solids; and (4) trends in dissolved-solids concentrations over time in basin-fill aquifers and streams, and the relation of trends to natural or human factors.
Water volume and sediment accumulation in Lake Linganore, Frederick County, Maryland, 2009
Sekellick, Andrew J.; Banks, S.L.
2010-01-01
To assist in understanding sediment and phosphorus loadings and the management of water resources, a bathymetric survey was conducted at Lake Linganore in Frederick County, Maryland in June 2009 by the U.S. Geological Survey, in cooperation with the City of Frederick and Frederick County, Maryland. Position data and water-depth data were collected using a survey grade echo sounder and a differentially corrected global positioning system. Data were compiled and edited using geographic information system software. A three-dimensional triangulated irregular network model of the lake bottom was created to calculate the volume of stored water in the reservoir. Large-scale topographic maps of the valley prior to inundation in 1972 were provided by the City of Frederick and digitized. The two surfaces were compared and a sediment volume was calculated. Cartographic representations of both water depth and sediment accumulation were produced along with an area/capacity table. An accuracy assessment was completed on the resulting bathymetric model. Vertical accuracy at the 95-percent confidence level for the collected data, the bathymetric surface model, and the bathymetric contour map was calculated to be 0.95 feet, 1.53 feet, and 3.63 feet, respectively. The water storage volume of Lake Linganore was calculated to be 1,860 acre-feet at full pool elevation. Water volume in the reservoir has decreased by 350 acre-feet (about 16 percent) in the 37 years since the dam was constructed. The total calculated volume of sediment deposited in the lake since 1972 is 313 acre-feet. This represents an average rate of sediment accumulation of 8.5 acre-feet per year since Linganore Creek was impounded. A sectional analysis of sediment distribution indicates that the most upstream third of Lake Linganore contains the largest volume of sediment whereas the section closest to the dam contains the largest amount of water. In comparison to other Maryland Piedmont reservoirs, Lake Linganore was found to have one of the lowest sedimentation rates at 0.26 cubic yards per year per acre of drainage area. Sedimentation rates in other comparable Maryland reservoirs were Prettyboy Reservoir (filling at a rate of 2.26 cubic yards per year per acre), Loch Raven Reservoir (filling at a rate of 0.88 cubic yards per year per acre) and Piney Run Reservoir (filling at a negligible rate).
[Autologous fat grafting in children].
Baptista, C; Bertrand, B; Philandrianos, C; Degardin, N; Casanova, D
2016-10-01
Lipofilling or fat grafting transfer is defined as a technique of filling soft tissue by autologous fat grafting. The basic principle of lipofilling is based on a harvest of adipose tissue, followed by a reinjection after treatment. Lipofilling main objective is a volume defect filling, but also improving cutaneous trophicity. Lipofilling specificities among children is mainly based on these indications. Complications of autologous fat grafting among children are the same as those in adults: we distinguish short-term complications (intraoperative and perioperative) and the medium and long-term complications. The harvesting of fat tissue is the main limiting factor of the technique, due to low percentage of body fat of children. Indications of lipofilling among children may be specific or similar to those in adults. There are two types of indications: cosmetic, in which the aim of lipofilling is correcting a defect density, acquired (iatrogenic, post-traumatic scar) or malformation (otomandibular dysplasia, craniosynostosis, Parry Romberg syndrom, Poland syndrom, pectus excavatum…). The aim of functional indications is correcting a velar insufficiency or lagophthalmos. In the paediatric sector, lipofilling has become an alternative to the conventional techniques, by its reliability, safety, reproducibility, and good results. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Left ventricular pressure and volume data acquisition and analysis using LabVIEW.
Cassidy, S C; Teitel, D F
1997-03-01
To automate analysis of left ventricular pressure-volume data, we used LabVIEW to create applications that digitize and display data recorded from conductance and manometric catheters. Applications separate data into cardiac cycles, calculate parallel conductance, and calculate indices of left ventricular function, including end-systolic elastance, preload-recruitable stroke work, stroke volume, ejection fraction, stroke work, maximum and minimum derivative of ventricular pressure, heart rate, indices of relaxation, peak filling rate, and ventricular chamber stiffness. Pressure-volume loops can be graphically displayed. These analyses are exported to a text-file. These applications have simplified and automated the process of evaluating ventricular function.
Zhang, Wei; Zhong, Xing; Che, Wu
2018-02-01
To investigate nutrient leaching from extensive green roofs, green roof platforms were established to investigate the effluent quantity and quality during artificial rainfall. When the influent volume reached three times the empty bed volume, for which the cumulative rainfall was around 300 mm, the effluent TP and COD concentrations of green roof platforms filled with peat soil did not tend to stabilize. For a long-term operation, the substrate depths had little significant influence on TN, TP and COD concentrations of the green roof effluents. A normalized cumulative emission process method was proposed to discuss the difference in various pollutant leaching processes. Obvious differences in the leaching process of different contaminants for green roof platforms filled with various substrates were observed. For the green roof filled with modified substrates, the nitrogen and phosphorus pollutant leaching rates were relatively high in the initial stage of green roof operation and the phosphorus leaching rate was higher than that of nitrogen. The green roof is a sink for TN, but not for TP and COD in this study. The outcomes are critical for the selection of green roof substrates and also contribute to green roof maintenance.
Cardiopulmonary physiology: why the heart and lungs are inextricably linked.
Verhoeff, Kevin; Mitchell, Jamie R
2017-09-01
Because the heart and lungs are confined within the thoracic cavity, understanding their interactions is integral for studying each system. Such interactions include changes in external constraint to the heart, blood volume redistribution (venous return), direct ventricular interaction (DVI), and left ventricular (LV) afterload. During mechanical ventilation, these interactions can be amplified and result in reduced cardiac output. For example, increased intrathoracic pressure associated with mechanical ventilation can increase external constraint and limit ventricular diastolic filling and, therefore, output. Similarly, high intrathoracic pressures can alter blood volume distribution and limit diastolic filling of both ventricles while concomitantly increasing pulmonary vascular resistance, leading to increased DVI, which may further limit LV filling. While LV afterload is generally considered to decrease with increased intrathoracic pressure, the question arises if the reduced LV afterload is primarily a consequence of a reduced LV preload. A thorough understanding of the interaction between the heart and lungs can be complicated but is essential for clinicians and health science students alike. In this teaching review, we have attempted to highlight the present understanding of certain salient aspects of cardiopulmonary physiology and pathophysiology, as well as provide a resource for multidisciplined health science educators and students. Copyright © 2017 the American Physiological Society.
Lam, Cherry Wing Yu; Ikeda, Shinya
2017-05-01
Texture modifying abilities of whey protein microparticles are expected to be dependent on pH during heat-induced aggregation of whey protein in the microparticulation process. Therefore, whey protein microparticles were prepared at either pH 5.5 or 6.8 and their effects on small and large deformation properties of gellan gels containing whey protein microparticles as fillers were investigated. The majority of whey protein microparticles had diameters around 2 μm. Atomic force microscopy images showed that whey protein microparticles prepared at pH 6.8 partially collapsed and flatted by air-drying, while those prepared at pH 5.5 did not. The Young's modulus of filled gels adjusted to pH 5.5 decreased by the addition of whey protein microparticles, while those of filled gels adjusted to pH 6.8 increased with increasing volume fraction of filler particles. These results suggest that filler particles were weakly bonded to gel matrices at pH 5.5 but strongly at pH 6.8. Whey protein microparticles prepared at pH 5.5 showed more enhanced increases in the Young's modulus than those prepared at pH 6.8 at volume fractions between 0.2 and 0.4, indicating that microparticles prepared at pH 5.5 were mechanically stronger. The fracture stress of filled gels showed trends somewhat similar to those of the Young's modulus, while their fracture strains decreased by the addition of whey protein microparticles in all examined conditions, indicating that the primary effect of these filler particles was to enhance the brittleness of filled gels. © 2017 Institute of Food Technologists®.
Wu, Min-Kai; de Groot, Sjoerd D; van der Sluis, Luc W M; Wesselink, Paul R
2003-09-01
We sought to measure and calculate the percentage of the gutta-percha-filled area in the apical root canal after the use of a standardized or inverted master cone in cold lateral compaction.Study design Two groups of extracted mandibular premolars with a single canal were instrumented with instruments of the same size; furthermore, they were obturated with laterally compacted gutta-percha cones with AH26 used as a sealer. In the first group, a standardized master cone was used with its narrow end in an apical position, whereas in the other group, an inverted master cone was used with its wide end in an apical position. The 2 master cones had the same apical diameter and fit in the apical canal. After lateral compaction, horizontal sections were cut at a level 3 and 5 mm from the apex of each filled tooth. Photographs of the sections were taken by using a microscope equipped with a digital camera; the photos were then scanned as tagged-image file format images. The cross-sectional area of the canal and the gutta-percha were measured by using an image-analysis program. The percentage of gutta-percha-filled area was calculated. At both levels, the inverted master cone produced a significantly higher percentage, statistically, of gutta-percha-filled area than did the standardized master cone (P =.001 at 3 mm; P =.012 at 5 mm). The use of an inverted master cone in cold lateral compaction may facilitate the apical placement of accessory cones, significantly increasing the volume of gutta-percha while reducing the volume of sealer in the apical root canal.
Bombardini, Tonino; Gemignani, Vincenzo; Bianchini, Elisabetta; Venneri, Lucia; Petersen, Christina; Pasanisi, Emilio; Pratali, Lorenza; Alonso-Rodriguez, David; Pianelli, Mascia; Faita, Francesco; Giannoni, Massimo; Arpesella, Giorgio; Picano, Eugenio
2008-01-01
A cutaneous force-frequency relation recording system based on first heart sound amplitude vibrations has been recently validated. Second heart sound can be simultaneously recorded in order to quantify both systole and diastole duration. Aims 1- To assess the feasibility and extra-value of operator-independent, force sensor-based, diastolic time recording during stress. Methods We enrolled 161 patients referred for stress echocardiography (exercise 115, dipyridamole 40, pacing 6 patients). The sensor was fastened in the precordial region by a standard ECG electrode. The acceleration signal was converted into digital and recorded together with ECG signal. Both systolic and diastolic times were acquired continuously during stress and were displayed by plotting times vs. heart rate. Diastolic filling rate was calculated as echo-measured mitral filling volume/sensor-monitored diastolic time. Results Diastolic time decreased during stress more markedly than systolic time. At peak stress 62 of the 161 pts showed reversal of the systolic/diastolic ratio with the duration of systole longer than diastole. In the exercise group, at 100 bpm HR, systolic/diastolic time ratio was lower in the 17 controls (0.74 ± 0.12) than in patients (0.86 ± 0.10, p < 0.05 vs. controls). Diastolic filling rate increased from 101 ± 36 (rest) to 219 ± 92 ml/m2* s-1 at peak stress (p < 0.5 vs. rest). Conclusion Cardiological systolic and diastolic duration can be monitored during stress by using an acceleration force sensor. Simultaneous calculation of stroke volume allows monitoring diastolic filling rate. Stress-induced "systolic-diastolic mismatch" can be easily quantified and is associated to several cardiac diseases, possibly expanding the spectrum of information obtainable during stress. PMID:18426559
Accurate expressions for solar cell fill factors including series and shunt resistances
NASA Astrophysics Data System (ADS)
Green, Martin A.
2016-02-01
Together with open-circuit voltage and short-circuit current, fill factor is a key solar cell parameter. In their classic paper on limiting efficiency, Shockley and Queisser first investigated this factor's analytical properties showing, for ideal cells, it could be expressed implicitly in terms of the maximum power point voltage. Subsequently, fill factors usually have been calculated iteratively from such implicit expressions or from analytical approximations. In the absence of detrimental series and shunt resistances, analytical fill factor expressions have recently been published in terms of the Lambert W function available in most mathematical computing software. Using a recently identified perturbative relationship, exact expressions in terms of this function are derived in technically interesting cases when both series and shunt resistances are present but have limited impact, allowing a better understanding of their effect individually and in combination. Approximate expressions for arbitrary shunt and series resistances are then deduced, which are significantly more accurate than any previously published. A method based on the insights developed is also reported for deducing one-diode fits to experimental data.
Method and apparatus for sampling low-yield wells
Last, George V.; Lanigan, David C.
2003-04-15
An apparatus and method for collecting a sample from a low-yield well or perched aquifer includes a pump and a controller responsive to water level sensors for filling a sample reservoir. The controller activates the pump to fill the reservoir when the water level in the well reaches a high level as indicated by the sensor. The controller deactivates the pump when the water level reaches a lower level as indicated by the sensors. The pump continuously activates and deactivates the pump until the sample reservoir is filled with a desired volume, as indicated by a reservoir sensor. At the beginning of each activation cycle, the controller optionally can select to purge an initial quantity of water prior to filling the sample reservoir. The reservoir can be substantially devoid of air and the pump is a low volumetric flow rate pump. Both the pump and the reservoir can be located either inside or outside the well.
48 CFR 8.405-4 - Price reductions.
Code of Federal Regulations, 2010 CFR
2010-10-01
...)), or in conjunction with the annual BPA review, there may be other reasons to request a price reduction... elsewhere at a lower price, or when establishing a BPA to fill recurring requirements. The potential volume...
46 CFR 154.1844 - Cargo tanks: Filling limits.
Code of Federal Regulations, 2010 CFR
2010-10-01
...; V=volume of the tank; dr=density at the reference temperature specified in paragraph (b) of this section; and dL=density of the cargo at the loading temperature and pressure. (b) The reference...
46 CFR 154.1844 - Cargo tanks: Filling limits.
Code of Federal Regulations, 2011 CFR
2011-10-01
...; V=volume of the tank; dr=density at the reference temperature specified in paragraph (b) of this section; and dL=density of the cargo at the loading temperature and pressure. (b) The reference...
46 CFR 154.1844 - Cargo tanks: Filling limits.
Code of Federal Regulations, 2014 CFR
2014-10-01
...; V=volume of the tank; dr=density at the reference temperature specified in paragraph (b) of this section; and dL=density of the cargo at the loading temperature and pressure. (b) The reference...
46 CFR 154.1844 - Cargo tanks: Filling limits.
Code of Federal Regulations, 2012 CFR
2012-10-01
...; V=volume of the tank; dr=density at the reference temperature specified in paragraph (b) of this section; and dL=density of the cargo at the loading temperature and pressure. (b) The reference...
The Shock and Vibration Digest. Volume 7, Number 5, May 1975.
Contents: Dynamic response of fluid-filled shells; News briefs; Short courses; Abstracts from the current literature -- (Analysis and design, computer programs, environments, phenomenology, experimentation, components, systems); Author index ; Literature review; Book reviews.
Liu, Q; Shao, L Q; Xiang, H F; Zhen, D; Zhao, N; Yang, S G; Zhang, X L; Xu, J
2013-01-01
An ideal material for maxillofacial prostheses has not been found. We created a novel material: silicone elastomer filled with hollow microspheres and characterized its biomechanical properties. Expancel hollow microspheres were mixed with MDX4-4210 silicone elastomer using Q7-9180 silicone fluid as diluent. The volume fractions of microspheres were 0, 5, 15, and 30% v/v (volume ratio to the total volume of MDX4-4210 and microspheres). The microspheres dispersed well in the matrix. The physical properties and biocompatibility of the composites were examined. Shock absorption was the greatest by the 5% v/v composite, and decreased with increasing concentrations of microspheres. The density, thermal conductivity, Shore A hardness, tear and tensile strength decreased with increasing concentrations of microspheres, while elongation at break increased. Importantly, the tear strength of all composites was markedly lower than that of pure silicone elastomer. Cell viability assays indicated that the composite was of good biocompatibility. The composite with a volume fraction of 5% exhibited the optimal properties for use as a maxillofacial prosthesis, though its tear strength was markedly lower than that of silicone elastomer. In conclusion, we developed a novel light and soft material with good flexibility and biocompatibility, which holds a promising prospect for clinical application as maxillofacial prosthesis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Asahina, Yuta; Kawashima, Tomohisa; Furukawa, Naoko
The formation mechanism of CO clouds observed with the NANTEN2 and Mopra telescopes toward the stellar cluster Westerlund 2 is studied by 3D magnetohydrodynamic simulations, taking into account the interstellar cooling. These molecular clouds show a peculiar shape composed of an arc-shaped cloud on one side of the TeV γ -ray source HESS J1023-575 and a linear distribution of clouds (jet clouds) on the other side. We propose that these clouds are formed by the interaction of a jet with clumps of interstellar neutral hydrogen (H i). By studying the dependence of the shape of dense cold clouds formed bymore » shock compression and cooling on the filling factor of H i clumps, we found that the density distribution of H i clumps determines the shape of molecular clouds formed by the jet–cloud interaction: arc clouds are formed when the filling factor is large. On the other hand, when the filling factor is small, molecular clouds align with the jet. The jet propagates faster in models with small filling factors.« less
Aldred, Rachel; Goodman, Anna; Gulliver, John; Woodcock, James
2018-08-01
Cycling injury risk is an important topic, but few studies explore cycling risk in relation to exposure. This is largely because of a lack of exposure data, in other words how much cycling is done at different locations. This paper helps to fill this gap. It reports a case-control study of cycling injuries in London in 2013-2014, using modelled cyclist flow data alongside datasets covering some characteristics of the London route network. A multilevel binary logistic regression model is used to investigate factors associated with injury risk, comparing injury sites with control sites selected using the modelled flow data. Findings provide support for 'safety in numbers': for each increase of a natural logarithmic unit (2.71828) in cycling flows, an 18% decrease in injury odds was found. Conversely, increased motor traffic volume is associated with higher odds of cycling injury, with one logarithmic unit increase associated with a 31% increase in injury odds. Twenty-mile per hour compared with 30mph speed limits were associated with 21% lower injury odds. Residential streets were associated with reduced injury odds, and junctions with substantially higher injury odds. Bus lanes do not affect injury odds once other factors are controlled for. These data suggest that speed limits of 20 mph may reduce cycling injury risk, as may motor traffic reduction. Further, building cycle routes that generate new cycle trips should generate 'safety in numbers' benefits. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
Warger, William C.; Hostens, Jeroen; Namati, Eman; Birngruber, Reginald; Bouma, Brett E.; Tearney, Guillermo J.
2012-01-01
Abstract. Optical coherence tomography (OCT) has been increasingly used for imaging pulmonary alveoli. Only a few studies, however, have quantified individual alveolar areas, and the validity of alveolar volumes represented within OCT images has not been shown. To validate quantitative measurements of alveoli from OCT images, we compared the cross-sectional area, perimeter, volume, and surface area of matched subpleural alveoli from microcomputed tomography (micro-CT) and OCT images of fixed air-filled swine samples. The relative change in size between different alveoli was extremely well correlated (r>0.9, P<0.0001), but OCT images underestimated absolute sizes compared to micro-CT by 27% (area), 7% (perimeter), 46% (volume), and 25% (surface area) on average. We hypothesized that the differences resulted from refraction at the tissue–air interfaces and developed a ray-tracing model that approximates the reconstructed alveolar size within OCT images. Using this model and OCT measurements of the refractive index for lung tissue (1.41 for fresh, 1.53 for fixed), we derived equations to obtain absolute size measurements of superellipse and circular alveoli with the use of predictive correction factors. These methods and results should enable the quantification of alveolar sizes from OCT images in vivo. PMID:23235834
NASA Astrophysics Data System (ADS)
Unglert, Carolin I.; Warger, William C.; Hostens, Jeroen; Namati, Eman; Birngruber, Reginald; Bouma, Brett E.; Tearney, Guillermo J.
2012-12-01
Optical coherence tomography (OCT) has been increasingly used for imaging pulmonary alveoli. Only a few studies, however, have quantified individual alveolar areas, and the validity of alveolar volumes represented within OCT images has not been shown. To validate quantitative measurements of alveoli from OCT images, we compared the cross-sectional area, perimeter, volume, and surface area of matched subpleural alveoli from microcomputed tomography (micro-CT) and OCT images of fixed air-filled swine samples. The relative change in size between different alveoli was extremely well correlated (r>0.9, P<0.0001), but OCT images underestimated absolute sizes compared to micro-CT by 27% (area), 7% (perimeter), 46% (volume), and 25% (surface area) on average. We hypothesized that the differences resulted from refraction at the tissue-air interfaces and developed a ray-tracing model that approximates the reconstructed alveolar size within OCT images. Using this model and OCT measurements of the refractive index for lung tissue (1.41 for fresh, 1.53 for fixed), we derived equations to obtain absolute size measurements of superellipse and circular alveoli with the use of predictive correction factors. These methods and results should enable the quantification of alveolar sizes from OCT images in vivo.
Improving poor fill factors for solar cells via light-induced plating
NASA Astrophysics Data System (ADS)
Zhao, Xing; Rui, Jia; Wuchang, Ding; Yanlong, Meng; Zhi, Jin; Xinyu, Liu
2012-09-01
Silicon solar cells are prepared following the conventional fabrication processes, except for the metallization firing process. The cells are divided into two groups with higher and lower fill factors, respectively. After light-induced plating (LIP), the fill factors of the solar cells in both groups with different initial values reach the same level. Scanning electron microscope (SEM) images are taken under the bulk silver electrodes, which prove that the improvement for cells with a poor factor after LIP should benefit from sufficient exploitation of the high density silver crystals formed during the firing process. Moreover, the application of LIP to cells with poor electrode contact performance, such as nanowire cells and radial junction solar cells, is proposed.
Densities and filling factors of the diffuse ionized gas in the Solar neighbourhood
NASA Astrophysics Data System (ADS)
Berkhuijsen, E. M.; Müller, P.
2008-10-01
Aims: We analyse electron densities and filling factors of the diffuse ionized gas (DIG) in the Solar neighbourhood. Methods: We have combined dispersion measures and emission measures towards 38 pulsars at distances known to better than 50%, from which we derived the mean density in clouds, N_c, and their volume filling factor, F_v, averaged along the line of sight. The emission measures were corrected for absorption by dust and contributions from beyond the pulsar distance. Results: The scale height of the electron layer for our sample is 0.93± 0.13 kpc and the midplane electron density is 0.023± 0.004 cm-3, in agreement with earlier results. The average density along the line of sight is < n_e> = 0.018± 0.002 cm-3 and is nearly constant. Since < n_e> = F_vN_c, an inverse relationship between Fv and Nc is expected. We find F_v(N_c) = (0.011± 0.003) N_c-1.20± 0.13, which holds for the ranges N_c= 0.05-1 cm-3 and F_v= 0.4-0.01. Near the Galactic plane the dependence of Fv on Nc is significantly stronger than away from the plane. Fv does not systematically change along or perpendicular to the Galactic plane, but the spread about the mean value of 0.08± 0.02 is considerable. The total pathlength through the ionized regions increases linearly to about 80 pc towards |z| = 1 kpc. Conclusions: Our study of Fv and Nc of the DIG is the first one based on a sample of pulsars with known distances. We confirm the existence of a tight, nearly inverse correlation between Fv and Nc in the DIG. The exact form of this relation depends on the regions in the Galaxy probed by the pulsar sample. The inverse F_v-Nc relation is consistent with a hierarchical, fractal density distribution in the DIG caused by turbulence. The observed near constancy of < n_e> then is a signature of fractal structure in the ionized medium, which is most pronounced outside the thin disk.
NASA Astrophysics Data System (ADS)
Schrott, Lothar; Hufschmidt, Gabi; Hankammer, Martin; Hoffmann, Thomas; Dikau, Richard
2003-09-01
Spatial patterns of sediment storage types and associated volumes using a novel approach for quantifying valley fill deposits are presented for a small alpine catchment (17 km 2) in the Bavarian Alps. The different sediment storage types were analysed with respect to geomorphic coupling and sediment flux activity. The most landforms in the valley in terms of surface area were found to be talus slopes (sheets and cones) followed by rockfall deposits and alluvial fans and plains. More than two-thirds of the talus slopes are relict landforms, completely decoupled from the geomorphic system. Notable sediment transport is limited to avalanche tracks, debris flows, and along floodplains. Sediment volumes were calculated using a combination of polynomial functions of cross sections, seismic refraction, and GIS modelling. A total of, 66 seismic refraction profiles were carried out throughout the valley for a more precise determination of sediment thicknesses and to check the bedrock data generated from geomorphometric analysis. We calculated the overall sediment volume of the valley fill deposits to be 0.07 km 3. This corresponds to a mean sediment thickness of 23.3 m. The seismic refraction data showed that large floodplains and sedimentation areas, which have been developed through damming effects from large rockfalls, are in general characterised by shallow sediment thicknesses (<20 m). By contrast, the thickness of several talus slopes is more than twice as much. For some locations (e.g., narrow sections of valley), the polynomial-generated cross sections resulted in overestimations of up to one order of magnitude; whereas in sections with a moderate valley shape, the modelled cross sections are in good accordance with the obtained seismic data. For the quantification of valley fill deposits, a combined application of bedrock data derived from polynomials and geophysical prospecting is highly recommended.
Diversity in general surgery: a period of progress.
Andriole, Dorothy A; Klingensmith, Mary E; Schechtman, Kenneth B
2005-01-01
Although 1996 to 2002 was a period of declining interest in general surgery (GS) among U.S. medical students (USS), most categorical general surgery (C-GS) training positions offered in the National Residency Matching Program (NRMP) continued to fill. We measured the impact of the decreasing U.S. student applicant volume on C-GS match outcomes and GS resident workforce composition over this time period. Match outcomes were analyzed for 7 applicant categories. Subsequent GS resident workforce compositions were analyzed for proportions of U.S. allopathic medical school graduates (USG), osteopathic medical graduates (OMG), Canadian MG (CMG), foreign MG (FMG), female physicians, and African-American physicians. Mantel-Haenzel chi-square tests measured trends in match percentages, C-GS positions filled, and GS workforce composition. All p-values are 2-sided. Increasing match percentages for USS applicants (p < 0.0001) and USG (p = 0.001), with a decreasing percentage of C-GS positions filled by these applicants (p < 0.0001), were from declining applicant volumes. Increasing match percentage for non-U.S. allopathic medical applicants reflected increases in both applicant volumes and matched applicants, with an increasing percentage of C-GS positions filled by these applicants (p < 0.0001). The subsequent resident workforce included increasing proportions of FMGs and OMGs (each p < 0.001); proportions of USG MDs and CMGs decreased (p < 0.0001 and p < 0.02, respectively). Concurrently, there were increasing numbers and proportions of female physicians (p < 0.0001) and African-American physicians (p < 0.0001) in the general surgery resident workforce. Declining interest among U.S. students in GS has resulted in a workforce comprised of residents from a broad range of educational backgrounds, but also it has provided an opportunity for progress toward achievement of a GS resident physician workforce more equitably representative of the racial and gender composition of our society at large.
An investigation of microstructural characteristics of contact-lens polymers
NASA Technical Reports Server (NTRS)
Singh, Jag J.; Eftekhari, Abe; Upchurch, Billy T.; Burns, Karen S.
1990-01-01
The free volume and gas permeability in several contact lens specimens were measured as part of a Space Commercialization Program. Free volume was measured using positron lifetime spectroscopy, while permeability for O2, N2, CO2 gases was measured using mass spectrometry and polarography. Permeability for all gases increases with the mean free volume cell size in the test samples. As might be expected, the specimens with the highest free volume fraction also exhibit the lowest Rockwell Hardness Number. An interesting corollary is the finding that the presence of fluorine atoms in the lens chemical structure inhibits filling up of their free volume cells. This is expected to allow the lenses to breathe freely while in actual use.
Understanding Thiel Embalming in Pig Kidneys to Develop a New Circulation Model
Willaert, Wouter; De Vos, Marie; Van Hoof, Tom; Delrue, Louke; Pattyn, Piet; D’Herde, Katharina
2015-01-01
The quality of tissue preservation in Thiel embalmed bodies varies. Research on the administered embalming volume and its vascular distribution may elucidate one of the mechanisms of tissue preservation and allow for new applications of Thiel embalming. Vascular embalming with (group 1, n = 15) or without (group 2, n = 20) contrast agent was initiated in pig kidneys. The distribution of Thiel embalming solution in group 1 was visualized using computed tomography. The kidneys in both groups were then immersed in concentrated salt solutions to reduce their weight and volume. Afterwards, to mimic a lifelike circulation in the vessels, group 2 underwent pump-driven reperfusion for 120 minutes with either paraffinum perliquidum or diluted polyethylene glycol. The circulation was imaged with computed tomography. All of the kidneys were adequately preserved. The embalming solution spread diffusely in the kidney, but fluid accumulation was present. Subsequent immersion in concentrated salt solutions reduced weight (P < 0.01) and volume (P < 0.01). Reperfusion for 120 minutes was established in group 2. Paraffinum perliquidum filled both major vessels and renal tissue, whereas diluted polyethylene glycol spread widely in the kidney. There were no increases in weight (P = 0.26) and volume (P = 0.79); and pressure further decreased (P = 0.032) after more than 60 minutes of reperfusion with paraffinum perliquidum, whereas there were increases in weight (P = 0.005), volume (P = 0.032) and pressure (P < 0.0001) after reperfusion with diluted polyethylene glycol. Arterial embalming of kidneys results in successful preservation due to complete parenchymatous spreading. More research is needed to determine whether other factors affect embalming quality. Dehydration is an effective method to regain the organs’ initial status. Prolonged vascular reperfusion with paraffinum perliquidum can be established in this model without increases in weight, volume and pressure. PMID:25806527
Maximum projection designs for computer experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joseph, V. Roshan; Gul, Evren; Ba, Shan
Space-filling properties are important in designing computer experiments. The traditional maximin and minimax distance designs only consider space-filling in the full dimensional space. This can result in poor projections onto lower dimensional spaces, which is undesirable when only a few factors are active. Restricting maximin distance design to the class of Latin hypercubes can improve one-dimensional projections, but cannot guarantee good space-filling properties in larger subspaces. We propose designs that maximize space-filling properties on projections to all subsets of factors. We call our designs maximum projection designs. As a result, our design criterion can be computed at a cost nomore » more than a design criterion that ignores projection properties.« less
Maximum projection designs for computer experiments
Joseph, V. Roshan; Gul, Evren; Ba, Shan
2015-03-18
Space-filling properties are important in designing computer experiments. The traditional maximin and minimax distance designs only consider space-filling in the full dimensional space. This can result in poor projections onto lower dimensional spaces, which is undesirable when only a few factors are active. Restricting maximin distance design to the class of Latin hypercubes can improve one-dimensional projections, but cannot guarantee good space-filling properties in larger subspaces. We propose designs that maximize space-filling properties on projections to all subsets of factors. We call our designs maximum projection designs. As a result, our design criterion can be computed at a cost nomore » more than a design criterion that ignores projection properties.« less
Transport equations for subdiffusion with nonlinear particle interaction.
Straka, P; Fedotov, S
2015-02-07
We show how the nonlinear interaction effects 'volume filling' and 'adhesion' can be incorporated into the fractional subdiffusive transport of cells and individual organisms. To this end, we use microscopic random walk models with anomalous trapping and systematically derive generic non-Markovian and nonlinear governing equations for the mean concentrations of the subdiffusive cells or organisms. We uncover an interesting interaction between the nonlinearities and the non-Markovian nature of the transport. In the subdiffusive case, this interaction manifests itself in a nontrivial combination of nonlinear terms with fractional derivatives. In the long time limit, however, these equations simplify to a form without fractional operators. This provides an easy method for the study of aggregation phenomena. In particular, this enables us to show that volume filling can prevent "anomalous aggregation," which occurs in subdiffusive systems with a spatially varying anomalous exponent. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Rahimi, Alireza; Sepehr, Mohammad; Lariche, Milad Janghorban; Mesbah, Mohammad; Kasaeipoor, Abbas; Malekshah, Emad Hasani
2018-03-01
The lattice Boltzmann simulation of natural convection in H-shaped cavity filled with nanofluid is performed. The entropy generation analysis and heatline visualization are employed to analyze the considered problem comprehensively. The produced nanofluid is SiO2-TiO2/Water-EG (60:40) hybrid nanofluid, and the thermal conductivity and dynamic viscosity of used nanofluid are measured experimentally. To use the experimental data of thermal conductivity and dynamic viscosity, two sets of correlations based on temperature for six different solid volume fractions of 0.5, 1, 1.5, 2, 2.5 and 3 vol% are derived. The influences of different governing parameters such different aspect ratio, solid volume fractions of nanofluid and Rayleigh numbers on the fluid flow, temperature filed, average/local Nusselt number, total/local entropy generation and heatlines are presented.
NASA Astrophysics Data System (ADS)
Al-Rashed, Abdullah A. A. A.; Kolsi, Lioua; Oztop, Hakan F.; Aydi, Abdelkarim; Malekshah, Emad Hasani; Abu-Hamdeh, Nidal; Borjini, Mohamed Naceur
2018-05-01
A computational study has been performed to investigate the effects of partially active magnetic field on natural convection heat transfer in CNT-nanofluid filled and three-dimensional differentially heated closed space. Two cases are considered to see this effect as magnetic field is applied to upper half (Case I) and lower half (Case II) while remaining walls are insulated. The finite volume method is used to solve governing equations and results are obtained for different governing parameters as Hartmann number (0 ≤ Ha ≤ 100), nanoparticle volume fraction (0 ≤ φ ≤ 0.05) and height of the active zone (0 ≤ LB ≤ 1). It is found that location of magnetic field plays an important role even at the same Hartmann number. Thus, it can be a good parameter to control heat and fluid flow inside the closed space.
Gupta, Deepak K; Giugliano, Robert P; Ruff, Christian T; Claggett, Brian; Murphy, Sabina; Antman, Elliott; Mercuri, Michele F.; Braunwald, Eugene; Solomon, Scott D
2016-01-01
Background Atrial fibrillation (AF) is associated with increased risk for thromboembolism and death; however, the relationships between cardiac structure and function and adverse outcomes among individuals with AF are incompletely understood. Methods The ENGAGE AF –TIMI 48 study tested the once-daily oral factor Xa inhibitor edoxaban in comparison to warfarin for the prevention of stroke (ischemic or hemorrhagic) or systemic embolism in 21,105 subjects with nonvalvular AF and increased risk for thromboembolic events (CHADS2 ≥ 2). In a prospective substudy of 971 subjects who underwent transthoracic echocardiography at baseline, we used Cox proportional hazards models to evaluate the associations between cardiac structure and function and the risks for death and thromboembolism (ischemic stroke, TIA, or systemic embolism). Results Over a median follow up of 2.5 years, 89 (9.2%) deaths and 48 (4.9%) incident thromboembolic events occurred in 971 subjects. In models adjusted for CHADS2 score, aspirin use, and randomized treatment, larger LV end diastolic volume index (HR: 1.49 [95%CI: 1.16,1.91] per 1 SD [12.9 ml/m2]) and higher LV filling pressures measured by E/′e (HR: 1.32 [95%CI: 1.08,1.61] per 1 SD [4.6]) were independently associated with increased risks for death. E/e′ > 13 significantly improved prediction of death beyond clinical factors alone. No features of cardiac structure and function were independently associated with thromboembolism in this population. Findings were similar when adjusted for CHA2DS2-VASc in place of CHADS2. Conclusions In a contemporary population of patients with atrial fibrillation at increased risk for thromboembolic events, larger LV size and higher filling pressures were significantly associated with increased risk for death, but neither left atrial nor left ventricular measures were associated with thromboembolic risk. LV size and filling pressures may help identify AF patients at increased risk of death. PMID:27106009
Ravicz, Michael E; Chien, Wade W; Rosowski, John J
2015-10-01
The effect of small amounts of air on sound-induced umbo velocity in an otherwise saline-filled middle ear (ME) was investigated to examine the efficacy of a novel balloon-like air-filled ME implant suitable for patients with chronically non-aerated MEs. In this study, air bubbles or air-filled implants were introduced into saline-filled human cadaveric MEs. Umbo velocity, a convenient measure of ME response, served as an indicator of hearing sensitivity. Filling the ME with saline reduced umbo velocity by 25-30 dB at low frequencies and more at high frequencies, consistent with earlier work (Ravicz et al., Hear. Res. 195: 103-130 (2004)). Small amounts of air (∼30 μl) in the otherwise saline-filled ME increased umbo velocity substantially, to levels only 10-15 dB lower than in the dry ME, in a frequency- and location-dependent manner: air in contact with the tympanic membrane (TM) increased umbo velocity at all frequencies, while air located away from the TM increased umbo velocity only below about 500 Hz. The air-filled implant also affected umbo velocity in a manner similar to an air bubble of equivalent compliance. Inserting additional implants into the ME had the same effect as increasing air volume. These results suggest these middle-ear implants would significantly reduce conductive hearing loss in patients with chronically fluid-filled MEs. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Treumann, R. A.; Baumjohann, W.
2015-10-01
The present review concerns the relevance of collisionless reconnection in the astrophysical context. Emphasis is put on recent developments in theory obtained from collisionless numerical simulations in two and three dimensions. It is stressed that magnetic reconnection is a universal process of particular importance under collisionless conditions, when both collisional and anomalous dissipation are irrelevant. While collisional (resistive) reconnection is a slow, diffusive process, collisionless reconnection is spontaneous. On any astrophysical time scale, it is explosive. It sets on when electric current widths become comparable to the leptonic inertial length in the so-called lepton (electron/positron) "diffusion region", where leptons de-magnetise. Here, the magnetic field contacts its oppositely directed partner and annihilates. Spontaneous reconnection breaks the original magnetic symmetry, violently releases the stored free energy of the electric current, and causes plasma heating and particle acceleration. Ultimately, the released energy is provided by mechanical motion of either the two colliding magnetised plasmas that generate the current sheet or the internal turbulence cascading down to lepton-scale current filaments. Spontaneous reconnection in such extended current sheets that separate two colliding plasmas results in the generation of many reconnection sites (tearing modes) distributed over the current surface, each consisting of lepton exhausts and jets which are separated by plasmoids. Volume-filling factors of reconnection sites are estimated to be as large as {<}10^{-5} per current sheet. Lepton currents inside exhausts may be strong enough to excite Buneman and, for large thermal pressure anisotropy, also Weibel instabilities. They bifurcate and break off into many small-scale current filaments and magnetic flux ropes exhibiting turbulent magnetic power spectra of very flat power-law shape W_b∝ k^{-α } in wavenumber k with power becoming as low as α ≈ 2. Spontaneous reconnection generates small-scale turbulence. Imposed external turbulence tends to temporarily increase the reconnection rate. Reconnecting ultra-relativistic current sheets decay into large numbers of magnetic flux ropes composed of chains of plasmoids and lepton exhausts. They form highly structured current surfaces, "current carpets". By including synchrotron radiation losses, one favours tearing-mode reconnection over the drift-kink deformation of the current sheet. Lepton acceleration occurs in the reconnection-electric field in multiple encounters with the exhausts and plasmoids. This is a Fermi-like process. It results in power-law tails on the lepton energy distribution. This effect becomes pronounced in ultra-relativistic reconnection where it yields extremely hard lepton power-law energy spectra approaching F(γ )∝ γ ^{-1}, with γ the lepton energy. The synchrotron radiation limit becomes substantially exceeded. Relativistic reconnection is a probable generator of current and magnetic turbulence, and a mechanism that produces high-energy radiation. It is also identified as the ultimate dissipation mechanism of the mechanical energy in collisionless magnetohydrodynamic turbulent cascades via lepton-inertial-scale turbulent current filaments. In this case, the volume-filling factor is large. Magnetic turbulence causes strong plasma heating of the entire turbulent volume and violent acceleration via spontaneous lepton-scale reconnection. This may lead to high-energy particle populations filling the whole volume. In this case, it causes non-thermal radiation spectra that span the entire interval from radio waves to gamma rays.
Speich, John E; Wilson, Cameron W; Almasri, Atheer M; Southern, Jordan B; Klausner, Adam P; Ratz, Paul H
2012-10-01
The length-tension (L-T) relationships in rabbit detrusor smooth muscle (DSM) are similar to those in vascular and airway smooth muscles and exhibit short-term length adaptation characterized by L-T curves that shift along the length axis as a function of activation and strain history. In contrast to skeletal muscle, the length-active tension (L-T(a)) curve for rabbit DSM strips does not have a unique peak tension value with a single ascending and descending limb. Instead, DSM can exhibit multiple ascending and descending limbs, and repeated KCl-induced contractions at a particular muscle length on an ascending or descending limb display increasingly greater tension. In the present study, mouse bladder strips with and without urothelium exhibited KCl-induced and carbachol-induced length adaptation, and the pressure-volume relationship in mouse whole bladder displayed short-term volume adaptation. Finally, prostaglandin-E(2)-induced low-level rhythmic contraction produced length adaptation in rabbit DSM strips. A likely role of length adaptation during bladder filling is to prepare DSM cells to contract efficiently over a broad range of volumes. Mammalian bladders exhibit spontaneous rhythmic contraction (SRC) during the filling phase and SRC is elevated in humans with overactive bladder (OAB). The present data identify a potential physiological role for SRC in bladder adaptation and motivate the investigation of a potential link between short-term volume adaptation and OAB with impaired contractility.
van Zyl, S P; Gulabivala, K; Ng, Y-L
2005-09-01
(i) To compare the prevalence of extrusion of root filling material when placed using different root filling techniques, with or without customization of the master gutta-percha (GP) cone; and (ii) to investigate the effects of some factors influencing root filling extrusion and presence of voids. A total of 180 roots were selected, prepared and randomly allocated to three groups. Five general dental practitioners performed the root fillings; each filled one group of roots (n = 60) using each of three techniques; 'cold lateral compaction' (n = 20), 'warm vertical compaction' (n = 20) and 'continuous-wave' (n = 20) techniques. For each obturation technique, the master GP cone was customized using chloroform in 10 samples. Two groups of the roots were recycled to allow all five operators to fulfill their remit. Two observers, blind to operator and obturation technique, examined the radiographs (master apical file, post-obturation) to determine the presence of root filling extrusion and voids within the apical 5 mm, independently. Root filling extrusion was also confirmed by direct inspection of the root apex after obturation. The data were analysed using logistic regression models. A total of 300 root fillings were performed; nine were excluded from the analysis. Most of the root fillings (80%, n = 233) were placed within 0.5 mm of the working length; only 20% (n = 58) were placed >0.5 mm beyond the working length. The odds of prevalence of extrusion (>0.5 mm) were significantly reduced by about 50% when cold lateral compaction or customization of GP were used. One operator produced 2.5 times more extruded root fillings than others. Curvature & length of root canal, apical size of prepared canal, as well as operator's preferred obturation technique had no significant influence on the prevalence of extrusion. Customization of GP was the sole factor to significantly reduce the prevalence of voids within the apical 5 mm of working length. Root filling extrusion was significantly influenced by 'operator' and was reduced by cold lateral compaction and customization of the master cone. Customization of master cone was the only factor that reduced voids apically.
[Continuous registration of the filling volume of the human urinary bladder].
Preussner, P R
1991-11-01
A sensing system for continuous recording of bladder volume is described. The system is intended for use in particular in patients with paraplegia or bladder plastique. Owing to the very simple measuring procedure employed the implantable components can be designed for very low power consumption. Also, there is no need for an additional data transfer from inside the body to the exterior, because measurement and telemetry are physically the same procedures.
ERIC Educational Resources Information Center
Instituto Nacional para la Educacion de los Adultos, Mexico City (Mexico).
These workbooks are part of a Mexican series of instructional materials designed for Spanish speaking adults who are in the process becoming literate or have recently become literate in their native language. They provide readings and exercises for developing literacy skills. Pictures and fill-in-the blank exercises appear frequently. Volume 1…
Subresolution Fibrillation in X-Ray Microflares Observed by Yohkoh SXT
NASA Technical Reports Server (NTRS)
Moore, Ron; Falconer, David; Porter, Jason
1999-01-01
We analyze the cooling of the X-ray plasma in microflares observed in active regions by the Yohkoh Soft X-ray Telescope (SXT). A typical microflare appears to be a transient brightening of an entire small magnetic loop, often having a diameter near the limit of resolution (approx. 2 x 10(exp 8) cm). The plasma heated to X-ray temperatures in the body of the loop cools by emission of XUV radiation and by heat conduction to the cooler plasma at the feet of the loop. The cooling rate is determined by the plasma temperature and density and the loop length. The plasma density is determined from the observed X-ray brightness of the loop in combination with the temperature, the loop diameter, and the filling factor. The filling factor is the volume fraction of the loop occupied by the subset of magnetic tubes that is fluid by the X-ray plasma and that contains practically all of the X-ray plasma present in the microflare loop. Taking typical values from the hundreds of microflares measured by Shimizu (X-ray brightness through the thin aluminum filter - 4 x 10(exp 3) DN/s/pixeL lifetime approx. 5 min, temperature approx. 6 x 10(exp 6) K, loop length approx. 10(exp 9) cm, loop diameter approx. 3 x 10(exp 8) cm), we find that for filling factors greater than approx. 1%: (1) the cooling time is much shorter than the duration of the microflare, and (2) conductive cooling strongly dominates over radiative cooling. Because the cooling time is so short and because the conductive heat flux goes mainly into increasing the plasma density via chromospheric evaporation, we are compelled to conclude that: (1) heating to X-ray temperatures continues through nearly the entire lifetime of the microflare, (2) die heating keeps changing to different field lines, so that any one magnetic tube in the sequence of heated tubes emits X-rays only briefly in the life of the microflare, and (3) at any instant during the microflare the tubes filled with X-ray plasma occupy only a small fraction (approx. 10%) of the microflare loop. Hence, we expect that coronal X-ray images with spatial resolution 2-3 times better than from the Yohkoh SXT will show plenty of rapidly changing filamentary substructure in microflares. Our results also suggest that the heating in microflares may result from progressive reconnection similar to that inferred in many larger flares.
Passive and active ventricular elastances of the left ventricle
Zhong, Liang; Ghista, Dhanjoo N; Ng, Eddie YK; Lim, Soo T
2005-01-01
Background Description of the heart as a pump has been dominated by models based on elastance and compliance. Here, we are presenting a somewhat new concept of time-varying passive and active elastance. The mathematical basis of time-varying elastance of the ventricle is presented. We have defined elastance in terms of the relationship between ventricular pressure and volume, as: dP = EdV + VdE, where E includes passive (Ep) and active (Ea) elastance. By incorporating this concept in left ventricular (LV) models to simulate filling and systolic phases, we have obtained the time-varying expression for Ea and the LV-volume dependent expression for Ep. Methods and Results Using the patient's catheterization-ventriculogram data, the values of passive and active elastance are computed. Ea is expressed as: ; Epis represented as: . Ea is deemed to represent a measure of LV contractility. Hence, Peak dP/dt and ejection fraction (EF) are computed from the monitored data and used as the traditional measures of LV contractility. When our computed peak active elastance (Ea,max) is compared against these traditional indices by linear regression, a high degree of correlation is obtained. As regards Ep, it constitutes a volume-dependent stiffness property of the LV, and is deemed to represent resistance-to-filling. Conclusions Passive and active ventricular elastance formulae can be evaluated from a single-beat P-V data by means of a simple-to-apply LV model. The active elastance (Ea) can be used to characterize the ventricle's contractile state, while passive elastance (Ep) can represent a measure of resistance-to-filling. PMID:15707494
Premature melt solidification during mold filling and its influence on the as-cast structure
NASA Astrophysics Data System (ADS)
Wu, M.; Ahmadein, M.; Ludwig, A.
2018-03-01
Premature melt solidification is the solidification of a melt during mold filling. In this study, a numerical model is used to analyze the influence of the pouring process on the premature solidification. The numerical model considers three phases, namely, air, melt, and equiaxed crystals. The crystals are assumed to have originated from the heterogeneous nucleation in the undercooled melt resulting from the first contact of the melt with the cold mold during pouring. The transport of the crystals by the melt flow, in accordance with the socalled "big bang" theory, is considered. The crystals are assumed globular in morphology and capable of growing according to the local constitutional undercooling. These crystals can also be remelted by mixing with the superheated melt. As the modeling results, the evolutionary trends of the number density of the crystals and the volume fraction of the solid crystals in the melt during pouring are presented. The calculated number density of the crystals and the volume fraction of the solid crystals in the melt at the end of pouring are used as the initial conditions for the subsequent solidification simulation of the evolution of the as-cast structure. A five-phase volume-average model for mixed columnar-equiaxed solidification is used for the solidification simulation. An improved agreement between the simulation and experimental results is achieved by considering the effect of premature melt solidification during mold filling. Finally, the influences of pouring parameters, namely, pouring temperature, initial mold temperature, and pouring rate, on the premature melt solidification are discussed.
Right Atrial Deformation in Predicting Outcomes in Pediatric Pulmonary Hypertension.
Jone, Pei-Ni; Schäfer, Michal; Li, Ling; Craft, Mary; Ivy, D Dunbar; Kutty, Shelby
2017-12-01
Elevated right atrial (RA) pressure is a risk factor for mortality, and RA size is prognostic of adverse outcomes in pulmonary hypertension (PH). There is limited data on phasic RA function (reservoir, conduit, and pump) in pediatric PH. We sought to evaluate (1) the RA function in pediatric PH patients compared with controls, (2) compare the RA deformation indices with Doppler indices of diastolic dysfunction, functional capacity, biomarkers, invasive hemodynamics, and right ventricular functional indices, and (3) evaluate the potential of RA deformation indices to predict clinical outcomes. Sixty-six PH patients (mean age 7.9±4.7 years) were compared with 36 controls (7.7±4.4 years). RA and right ventricular deformation indices were obtained using 2-dimensional speckle tracking (2DCPA; TomTec, Germany). RA strain, strain rates, emptying fraction, and right ventricular longitudinal strain were measured. RA function was impaired in PH patients versus controls ( P <0.001). There were significant associations between RA function with invasive hemodynamics ( P <0.01). RA reservoir, pump function, the rate of RA filling, and atrial minimum volume predicted adverse clinical outcomes (hazard ratio [HR], 0.15; confidence interval [CI], 0.03-0.73; P <0.01; HR, 0.05; CI, 0.003-0.43; P <0.004; HR, 0.04; CI, 0.006-0.56; P <0.01; and HR, 8.6; CI, 1.6-37.2; P <0.01, respectively). RA deformation properties are significantly altered in pediatric PH patients. Progressive worsening of RA reservoir and conduit functions is related to changes in right ventricular diastolic dysfunction. RA reservoir function, pump function, the rate of atrial filling, and atrial minimum volume emerged as outcome predictors in pediatric PH. © 2017 American Heart Association, Inc.
Guy, Heather M; McCloskey, Laura; Lye, Gary J; Mitrophanous, Kyriacos A; Mukhopadhyay, Tarit K
2013-04-01
ProSavin(®) is a lentiviral vector (LV)-based gene therapy for Parkinson's disease. ProSavin(®) is currently in a Phase I/II clinical trial using material that was generated by transient transfection of adherent human embryonic kidney (HEK)293T cells. For future large-scale productions of ProSavin(®), we have previously reported the development and characterization of two inducible producer cell lines, termed PS5.8 and PS46.2. PS46.2 has been successfully adapted to grow in suspension cultures. The present study describes the creation of a small-scale (<2 ml) microwell-based experimental platform for the parallel investigation of ProSavin(®) production using suspension-adapted PS46.2. This is combined with statistical design of experiments (DoE) techniques to enable rapid characterization of the process conditions that impact cell growth and LV production. The effects of postinduction period, microwell liquid fill volume, and concentration of inducer (doxycycline) on ProSavin(®) titer and the particle:infectivity (P:I) ratio was investigated using three rounds of DoE, in order to identify appropriate factor ranges and optimize production conditions. We identified an optimal "harvest window" between approximately 26-46 hr within which maximal titers of around 6×10(4) transducing units (TU)/ml were obtained (an approximately 30-fold improvement compared to starting microwell conditions), providing that the fill volume was maintained at or below 1 ml and the doxycycline concentration was at least 1.0 μg/ml. Insights from the microwell studies were subsequently used to rapidly establish operating conditions for ProSavin(®) production in a 0.5-L wave bioreactor culture. The information presented herein thus aids the design and evaluation of scalable production processes for LVs.
NASA Technical Reports Server (NTRS)
Yalcin, F.; Aksoy, F. G.; Muderrisoglu, H.; Sabah, I.; Garcia, M. J.; Thomas, J. D.
2000-01-01
BACKGROUND: Hypertension is a major independent risk factor for cardiac deaths, and diastolic dysfunction is a usual finding during the course of this disease. HYPOTHESIS: This study was designed to investigate the effects of chronic therapy with perindopril on left ventricular (LV) mass, left atrial size, diastolic function, and plasma level of atrial natriuretic peptide (ANP) in patients with hypertension. METHODS: Twenty four patients who had not been previously taking any antihypertensive medication and without prior history of angina pectoris, myocardial infarction, congestive heart failure, dysrhythmias, valvular heart disease, or systemic illnesses received 4-8 mg/day of perindopril orally. Echocardiographic studies were acquired at baseline and 6 months after the initiation of therapy. RESULTS: Systolic and diastolic blood pressure decreased from 174 +/- 19.7 and 107.5 +/- 7.8 mmHg to 134 +/- 10.6 and 82 +/- 6.7 mmHg, respectively (p < 0.001). Left ventricular mass decreased from 252.4 +/- 8.3 to 205.7 +/- 7.08 g and left atrial volume from 20.4 +/- 5.1 to 17.6 +/- 5.2 ml, respectively (p < 0.001). Transmitral Doppler early and atrial filling velocity ratio (E/A) increased from 0.69 +/- 0.06 to 0.92 +/- 0.05 m/s and plasma ANP level decreased from 71.9 +/- 11.7 to 35.3 +/- 7.8 pg/ml (p < 0.001). Reduction of LV mass correlated positively with a reduction in ANP levels (r = 0.66, p < 0.0005). CONCLUSIONS: Perindopril caused a significant reduction of LV mass, left atrial volume, and plasma ANP levels, as well as improvement in Doppler parameters of LV filling in this group of patients with hypertension.
NASA Technical Reports Server (NTRS)
Stapleton, Thomas J. (Inventor)
2015-01-01
A concentric split flow filter may be configured to remove odor and/or bacteria from pumped air used to collect urine and fecal waste products. For instance, filter may be designed to effectively fill the volume that was previously considered wasted surrounding the transport tube of a waste management system. The concentric split flow filter may be configured to split the air flow, with substantially half of the air flow to be treated traveling through a first bed of filter media and substantially the other half of the air flow to be treated traveling through the second bed of filter media. This split flow design reduces the air velocity by 50%. In this way, the pressure drop of filter may be reduced by as much as a factor of 4 as compare to the conventional design.
Schneider, Caroline; Forsythe, Lynsey; Somauroo, John; George, Keith
2018-01-01
Background Left ventricular (LV) function is dependent on load, intrinsic contractility and relaxation with a variable impact on specific mechanics. Strain (ε) imaging allows the assessment of cardiac function; however, the direct relationship between volume and strain is currently unknown. The aim of this study was to establish the impact of preload reduction through head-up tilt (HUT) testing on simultaneous left ventricular (LV) longitudinal and transverse function and their respective contribution to volume change. Methods A focused transthoracic echocardiogram was performed on 10 healthy male participants (23 ± 3 years) in the supine position and following 1 min and 5 min of HUT testing. Raw temporal longitudinal ε (Ls) and transverse ε (Ts) values were exported and divided into 5% increments across the cardiac cycle and corresponding LV volumes were traced at each 5% increment. This provided simultaneous LV longitudinal and transverse ε and volume loops (deformation volume analysis – DVA). Results There was a leftward shift of the ε-volume loop from supine to 1 min and 5 min of HUT (P < 0.001). Moreover, longitudinal shortening was reduced (P < 0.001) with a concomitant increase in transverse thickening from supine to 1 min, which was further augmented at 5 min (P = 0.018). Conclusions Preload reduction occurs within 1 min of HUT but does not further reduce at 5 min. This decline is associated with a decrease in longitudinal ε and concomitant increase in transverse ε. Consequently, augmented transverse relaxation appears to be an important factor in the maintenance of LV filling in the setting of reduced preload. DVA provides information on the relative contribution of mechanics to a change in LV volume and may have a role in the assessment of clinical populations. PMID:29339401
Schneider, Caroline; Forsythe, Lynsey; Somauroo, John; George, Keith; Oxborough, David
2018-03-01
Left ventricular (LV) function is dependent on load, intrinsic contractility and relaxation with a variable impact on specific mechanics. Strain (ε) imaging allows the assessment of cardiac function; however, the direct relationship between volume and strain is currently unknown. The aim of this study was to establish the impact of preload reduction through head-up tilt (HUT) testing on simultaneous left ventricular (LV) longitudinal and transverse function and their respective contribution to volume change. A focused transthoracic echocardiogram was performed on 10 healthy male participants (23 ± 3 years) in the supine position and following 1 min and 5 min of HUT testing. Raw temporal longitudinal ε (Ls) and transverse ε (Ts) values were exported and divided into 5% increments across the cardiac cycle and corresponding LV volumes were traced at each 5% increment. This provided simultaneous LV longitudinal and transverse ε and volume loops (deformation volume analysis - DVA). There was a leftward shift of the ε-volume loop from supine to 1 min and 5 min of HUT ( P < 0.001). Moreover, longitudinal shortening was reduced ( P < 0.001) with a concomitant increase in transverse thickening from supine to 1 min, which was further augmented at 5 min ( P = 0.018). Preload reduction occurs within 1 min of HUT but does not further reduce at 5 min. This decline is associated with a decrease in longitudinal ε and concomitant increase in transverse ε. Consequently, augmented transverse relaxation appears to be an important factor in the maintenance of LV filling in the setting of reduced preload. DVA provides information on the relative contribution of mechanics to a change in LV volume and may have a role in the assessment of clinical populations. © 2018 The authors.
NASA Astrophysics Data System (ADS)
Zhong, Xin; Frehner, Marcel; Kunze, Karsten; Zappone, Alba
2014-10-01
A novel electron backscatter diffraction (EBSD) -based finite-element (FE) wave propagation simulation is presented and applied to investigate seismic anisotropy of peridotite samples. The FE model simulates the dynamic propagation of seismic waves along any chosen direction through representative 2D EBSD sections. The numerical model allows separation of the effects of crystallographic preferred orientation (CPO) and shape preferred orientation (SPO). The obtained seismic velocities with respect to specimen orientation are compared with Voigt-Reuss-Hill estimates and with laboratory measurements. The results of these three independent methods testify that CPO is the dominant factor controlling seismic anisotropy. Fracture fillings and minor minerals like hornblende only influence the seismic anisotropy if their volume proportion is sufficiently large (up to 23%). The SPO influence is minor compared to the other factors. The presented FE model is discussed with regard to its potential in simulating seismic wave propagation using EBSD data representing natural rock petrofabrics.
A loop resonator for slice-selective in vivo EPR imaging in rats
Hirata, Hiroshi; He, Guanglong; Deng, Yuanmu; Salikhov, Ildar; Petryakov, Sergey; Zweier, Jay L.
2008-01-01
A loop resonator was developed for 300-MHz continuous-wave electron paramagnetic resonance (CW-EPR) spectroscopy and imaging in live rats. A single-turn loop (55 mm in diameter) was used to provide sufficient space for the rat body. Efficiency for generating a radiofrequency magnetic field of 38 µT/W1/2 was achieved at the center of the loop. For the resonator itself, an unloaded quality factor of 430 was obtained. When a 350 g rat was placed in the resonator at the level of the lower abdomen, the quality factor decreased to 18. The sensitive volume in the loop was visualized with a bottle filled with an aqueous solution of the nitroxide spin probe 3-carbamoyl-2,2,5,5-tetramethyl-3-pyrrolin-1-yloxy (3-CP). The resonator was shown to enable EPR imaging in live rats. Imaging was performed for 3-CP that had been infused intravenously into the rat and its distribution was visualized within the lower abdomen. PMID:18006343
Apparatus and method for electrical insulation in plasma discharge systems
Rhodes, Mark A [Redwood City, CA; Fochs, Scott N [Livermore, CA
2003-08-12
An apparatus and method to contain plasma at optimal fill capacity of a metallic container is disclosed. The invention includes the utilization of anodized layers forming the internal surfaces of the container volume. Bias resistors are calibrated to provide constant current at variable voltage conditions. By choosing the appropriate values of the bias resistors, the voltages of the metallic container relative to the voltage of an anode are adjusted to achieve optimal plasma fill while minimizing the chance of reaching the breakdown voltage of the anodized layer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1994-08-01
This report comprises appendices A--J which support the Y-12 Plant`s remedial action report involving Chestnut Ridge Operable Unit 2 (filled coal ash pond/Upper McCoy Branch). The appendices cover the following: Sampling fish from McCoy Branch; well and piezometer logs; ecological effects of contaminants in McCoy Branch 1989-1990; heavy metal bioaccumulation data; microbes in polluted sediments; and baseline human health risk assessment data.
Combination film/splash fill for overcoming film fouling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phelps, P.M.; Minett, T.O.
1995-02-01
In summary, this large cooling tower user has found the Phelps film/splash Stack-Pack fill design to attain a substantial improvement in capability of their existing crossflow cooling towers, without increasing fan power or tower size. The lack of fouling in the film fill component of this fill design is due to the use of film fill with large (1 inch) spacing between sheets, coupled with effective water treatment as provided by Nalco. This combination of factors provides a proven method for significantly increasing crossflow or counterflow cooling tower capability while minimizing chances of serious fill fouling.
Commander Lousma is surrounded by a week's worth of trash on the middeck
NASA Technical Reports Server (NTRS)
1982-01-01
Commander Lousma, wearing communication kit assembly (ASSY) mini headset (HDST), gathers three freefloating plastic trash bags filled with empty containers, paper towels, straws, etc. Lousma will stow them in a designated stowage volume.
Technology for Space Station Evolution. Volume 5: Structures and Materials/Thermal Control System
NASA Technical Reports Server (NTRS)
1990-01-01
NASA's Office of Aeronautics and Space Technology (OAST) conducted a workshop on technology for space station evolution on 16-19 Jan. 1990. The purpose of this workshop was to collect and clarify Space Station Freedom technology requirements for evolution and to describe technologies that can potentially fill those requirements. These proceedings are organized into an Executive Summary and Overview and five volumes containing the Technology Discipline Presentations. Volume 5 consists of the technology discipline sections for Structures/Materials and the Thermal Control System. For each technology discipline, there is a level 3 subsystem description, along with papers.
Technology for Space Station Evolution. Volume 4: Power Systems/Propulsion/Robotics
NASA Technical Reports Server (NTRS)
1990-01-01
NASA's Office of Aeronautics and Space Technology (OAST) conducted a workshop on technology for space station evolution on 16-19 Jan. 1990. The purpose of this workshop was to collect and clarify Space Station Freedom technology requirements for evolution and to describe technologies that can potentially fill those requirements. These proceedings are organized into an Executive Summary and Overview and five volumes containing the Technology Discipline Presentations. Volume 4 consists of the technology discipline sections for Power, Propulsion, and Robotics. For each technology discipline, there is a Level 3 subsystem description, along with the papers.
NASA Astrophysics Data System (ADS)
Taylor, Stephen B.; Steven Kite, J.
2006-08-01
Factors that control the routing and storage of sediments in the Appalachian region are poorly understood. This study involves a comparative geomorphic analysis of three watersheds underlain by sandstones and shales of the Acadian clastic wedge. These areas include the Fernow Experimental Forest, Tucker County, West Virginia; the North Fork basin, Pocahontas County, West Virginia; and the Little River basin, Augusta County, Virginia. GIS-based analyses of surficial map units allow first-order approximation of sediment-storage volumes in valley bottoms. Estimates of volumes are examined in tandem with morphometric analyses and the distribution of bedrock channels to make inferences regarding controls on sediment-transport efficiency in the central Appalachians. The Fernow and North Fork areas are characterized by V-shaped valleys with mixed reaches of alluvial-bedrock channels distributed throughout the drainage network. In contrast, the Little River valley is notably wider and gravelly alluvial fill is abundant. Comparator watershed parameters for the Fernow, North Fork and Little River areas include, respectively: (1) basin area = 15.2 km 2, 49.3 km 2, 41.5 km 2; (2) basin relief = 0.586 km, 0.533 km, 0.828 km; (3) drainage density = 4.2 km - 1 , 3.3 km - 1 , 4.7 km - 1 ; (4) ruggedness = 2.5, 1.7, 3.9; (5) Shreve magnitude = 139, 287, 380; (6) total valley-bottom area (km 2) = 0.76 km 2, 1.86 km 2, 3.09 km 2; (7) average hillslope gradients = 17.2°, 18.4°, 22.1°; (8) total debris-fan surface area = 0.113 km 2, 0.165 km 2, 0.486 km 2; and (9) debris-fan frequency = 2.0 km - 2 , 1.0 km - 2 , 2.8 km - 2 . The storage volumes in valley bottoms were estimated using map polygon areas and surface heights above channel grade. The Little River contains significantly higher sediment volumes in floodplain, terrace and fan storage compartments; total volumes of the valley bottoms are approximately twice that of the Fernow and North Fork areas combined. Unit storage volumes for the Fernow, North Fork and Little River are 5.2 × 10 4 m 3 km - 2 , 5.5 × 10 4 m 3 km - 2 and 1.6 × 10 5 m 3 km - 2 , respectively. A conceptual model postulates that valley-width morphometry and style of delivery from hillslopes are the primary factors controlling the efficiency of sediment transport. Steep, debris-flow-prone hillslopes at the Little River deliver high volumes of gravelly sediment at magnitudes greater than transport capacity of the channel. Patterns of stream power are complex, as low-order tributaries are under capacity and high-order tributaries over capacity with respect to sediment load. Aggraded alluvial fill insulates valley-floor bedrock from vertical erosion and valley widening dominates. Expansion of the valley width creates a positive response via increased storage capacity and lower unit stream power. Conversely, the Fernow and North Fork are characterized by diffusive mass movement on hillslopes with incremental bedload transport to higher-order tributaries. Rates of hillslope delivery are balanced by the rate of channel export. Mixed alluvial-bedrock reaches provide the optimal channel configuration for active incision of the valley floor. Low expansion of valley width promotes high unit stream power and processes of vertical erosion. The model implies that the Fernow and North Fork have been more effective at sediment transport during the Late Quaternary. Given similar climatic and tectonic settings, variation in bedrock lithofacies is likely the primary factor modulating the efficiency of sediment transport.
Management of Mastectomy Skin Necrosis in Implant Based Breast Reconstruction.
Sue, Gloria R; Long, Chao; Lee, Gordon K
2017-05-01
Mastectomy skin necrosis is a significant problem after breast reconstruction. This complication may lead to poor wound healing and need for implant removal, which may delay subsequent oncologic treatment. We sought to characterize factors associated with mastectomy skin necrosis and propose a management algorithm. A retrospective review was performed on consecutive patients undergoing implant-based breast reconstruction by the senior author from 2006 through 2015. Patient-level factors including age, race, body mass index, history of hypertension, history of diabetes, history of smoking, and history of radiation were collected. Surgical factors including type of mastectomy, location of implant placement, and immediate versus delayed reconstruction were collected. The incidence and treatment of mastectomy skin necrosis were analyzed. A total of 293 patients underwent either unilateral or bilateral implant-based breast reconstructions after mastectomy with a total of 471 reconstructed breasts. Mastectomy skin necrosis was observed in 8.1% of reconstructed breasts. Skin necrosis was not associated with age, hypertension, diabetes, prior radiation, or type of mastectomy. The incidence of skin necrosis was higher among smokers (17.9% vs 5.0%, P < 0.001), among patients with higher body mass index (11.4% vs 6.1%, P = 0.05), patients who underwent immediate reconstruction compared to delayed (9.6% vs 0%, P = 0.004), placement of expander under acellular dermal matrix compared with submuscular placement (12.0% vs 5.2%, P = 0.02), and use of higher initial expander fill volume compared with lower fill volume (11.4% vs 5.4%, P = 0.02).The median necrosis size was 8 cm. The median time to treatment was 15 days postoperatively. In 55% of patients minor necrosis was treated with clinic debridement, whereas 43% had larger areas of necrosis requiring operative debridement. The median size treated with clinic debridement was 5.5 cm, compared to 15 cm for operative debridement. All necrosis was treated in a timely fashion and did not delay adjuvant therapy. Mastectomy skin necrosis occurred in 8.1% of breasts after implant-based reconstruction. Necrosis less than 10 cm can be treated successfully with local debridement in the clinic setting. Timely and appropriate treatment of skin necrosis with debridement and primary closure expedites wound healing and facilitates tissue expander breast reconstruction.
Dynamic Analysis of Gene Expression in Rice Superior and Inferior Grains by RNA-Seq
Sun, Hongzheng; Peng, Ting; Zhao, Yafan; Du, Yanxiu; Zhang, Jing; Li, Junzhou; Xin, Zeyu; Zhao, Quanzhi
2015-01-01
Poor grain filling of inferior grains located on lower secondary panicle branch causes great drop in rice yield and quality. Dynamic gene expression patterns between superior and inferior grains were examined from the view of the whole transcriptome by using RNA-Seq method. In total, 19,442 genes were detected during rice grain development. Genes involved in starch synthesis, grain storage and grain development were interrogated in particular in superior and inferior grains. Of the genes involved in sucrose to starch transformation process, most were expressed at lower level in inferior grains at early filling stage compared to that of superior grains. But at late filling stage, the expression of those genes was higher in inferior grains and lower in superior grains. The same trends were observed in the expression of grain storage protein genes. While, evidence that genes involved in cell cycle showed higher expression in inferior grains during whole period of grain filling indicated that cell proliferation was active till the late filling stage. In conclusion, delayed expression of most starch synthesis genes in inferior grains and low capacity of sink organ might be two important factors causing low filling rate of inferior grain at early filling stage, and shortage of carbohydrate supply was a limiting factor at late filling stage. PMID:26355995
The Surface Brightness Contribution of II Peg: A Comparison of TiO Band Analysis and Doppler Imaging
NASA Astrophysics Data System (ADS)
Senavci, H. V.; O'Neal, D.; Hussain, G. A. J.; Barnes, J. R.
2015-01-01
We investigate the surface brightness contribution of the very well known active SB1 binary II Pegasi , to determine the star spot filling factor and the spot temperature parameters. In this context, we analyze 54 spectra of the system taken over 6 nights in September - October of 1996, using the 2.1m Otto Struve Telescope equipped with SES at the McDonald Observatory. We measure the spot temperatures and spot filling factors by fitting TiO molecular bands in this spectroscopic dataset, with model atmosphere approximation using ATLAS9 and with proxy stars obtained with the same instrument. The same dataset is then used to also produce surface spot maps using the Doppler imaging technique. We compare the spot filling factors obtained with the two independent techniques in order to better characterise the spot properties of the system and to better assess the limitations inherent to both techniques. The results obtained from both techniques show that the variation of spot filling factor as a function of phase agree well with each other, while the amount of TiO and DI spot
NASA Astrophysics Data System (ADS)
Reynolds, Steven; Bucur, Adriana; Port, Michael; Alizadeh, Tooba; Kazan, Samira M.; Tozer, Gillian M.; Paley, Martyn N. J.
2014-02-01
Over recent years hyperpolarization by dissolution dynamic nuclear polarization has become an established technique for studying metabolism in vivo in animal models. Temporal signal plots obtained from the injected metabolite and daughter products, e.g. pyruvate and lactate, can be fitted to compartmental models to estimate kinetic rate constants. Modeling and physiological parameter estimation can be made more robust by consistent and reproducible injections through automation. An injection system previously developed by us was limited in the injectable volume to between 0.6 and 2.4 ml and injection was delayed due to a required syringe filling step. An improved MR-compatible injector system has been developed that measures the pH of injected substrate, uses flow control to reduce dead volume within the injection cannula and can be operated over a larger volume range. The delay time to injection has been minimized by removing the syringe filling step by use of a peristaltic pump. For 100 μl to 10.000 ml, the volume range typically used for mice to rabbits, the average delivered volume was 97.8% of the demand volume. The standard deviation of delivered volumes was 7 μl for 100 μl and 20 μl for 10.000 ml demand volumes (mean S.D. was 9 ul in this range). In three repeat injections through a fixed 0.96 mm O.D. tube the coefficient of variation for the area under the curve was 2%. For in vivo injections of hyperpolarized pyruvate in tumor-bearing rats, signal was first detected in the input femoral vein cannula at 3-4 s post-injection trigger signal and at 9-12 s in tumor tissue. The pH of the injected pyruvate was 7.1 ± 0.3 (mean ± S.D., n = 10). For small injection volumes, e.g. less than 100 μl, the internal diameter of the tubing contained within the peristaltic pump could be reduced to improve accuracy. Larger injection volumes are limited only by the size of the receiving vessel connected to the pump.
Li, Ka; Yan, Jun; Yang, Qiang; Li, Zhenfeng; Li, Jianmin
2015-01-28
For osteoporosis or spinal metastases, percutaneous vertebroplasty is effective in pain relief and improvement of mobility. However, the complication rate (cement extravasation and fat embolisms) is relatively higher in the treatment of spinal metastases. The presence of tumor tissue plays a significant role in intravertebral pressure and cement distribution and thereby affects the occurrence of complications. We investigated the effect of void creation prior to vertebroplasty on intravertebral pressure and cement distribution in spinal metastases. Eighteen vertebrae (T8-L4) from five cadaveric spines were randomly allocated for two groups (group with and without void) of nine vertebrae each. Defect was created by removing a central core of cancellous bone in the vertebral body and then filling it with 30% or 100% fresh muscle paste by volume to simulate void creation or no void creation, respectively. Then, 20% bone cement by volume of the vertebral body was injected into each specimen through a unipedicular approach at a rate of 3 mL/min. The gender of the donor, vertebral body size, bone density, cement volume, and intravertebral pressure were recorded. Then, computed tomography scans and cross sections were taken to evaluate the cement distribution in vertebral bodies. No significant difference was found between the two groups in terms of the gender of the donor, vertebral body size, bone density, or bone cement volume. The average maximum intravertebral pressure in the group with void creation was significantly lower than that in the group without void creation (1.20 versus 5.09 kPa, P = 0.001). Especially during the filling of void, the difference was more pronounced. Void creation prior to vertebroplasty allowed the bone cement to infiltrate into the lytic defect. In vertebroplasty for spinal metastases, void creation produced lower intravertebral pressure and facilitated cement filling. To reduce the occurrence of complication, it may be an alternative to eliminate the tumor tissue to create a void prior to cement injection.
Ruhl, Aki S; Jekel, Martin
2013-10-15
Permeable reactive barriers are successfully applied for the removal of various contaminants. The concomitant reduction of hydrogen ions and the subsequent formation of hydrogen gas by anaerobic corrosion lead to decreased pore volume filled with water and thus residence times, so called gas clogging. Long term column experiments were conducted to elucidate the impact of ubiquitous water constituents on the formation of hydrogen gas and potential passivation due to corrosion products. The collected gas volumes revealed a relation to the hydronium concentration (pH) but were only slightly increased in the presence of chloride and sulfate and not significantly influenced in the presence of phosphate, silicate, humic acid and ammonium compared to deionized water. Significant gas volumes within the reactive filling were verified by gravimetry. The presence of nitrate completely eliminated hydrogen formation by competition for electrons. Solid phase analyses revealed that neither chloride nor sulfate was incorporated in corrosion products in concentrations above 0.1 weight percent, and they did not alter the formation of mainly magnetite in comparison to deionized water. Copyright © 2013 Elsevier Ltd. All rights reserved.
Taylor bubbles at high viscosity ratios: experiments and numerical simulations
NASA Astrophysics Data System (ADS)
Hewakandamby, Buddhika; Hasan, Abbas; Azzopardi, Barry; Xie, Zhihua; Pain, Chris; Matar, Omar
2015-11-01
The Taylor bubble is a single long bubble which nearly fills the entire cross section of a liquid-filled circular tube, often occurring in gas-liquid slug flows in many industrial applications, particularly oil and gas production. The objective of this study is to investigate the fluid dynamics of three-dimensional Taylor bubble rising in highly viscous silicone oil in a vertical pipe. An adaptive unstructured mesh modelling framework is adopted here which can modify and adapt anisotropic unstructured meshes to better represent the underlying physics of bubble rising and reduce computational effort without sacrificing accuracy. The numerical framework consists of a mixed control volume and finite element formulation, a `volume of fluid'-type method for the interface-capturing based on a compressive control volume advection method, and a force-balanced algorithm for the surface tension implementation. Experimental results for the Taylor bubble shape and rise velocity are presented, together with numerical results for the dynamics of the bubbles. A comparison of the simulation predictions with experimental data available in the literature is also presented to demonstrate the capabilities of our numerical method. EPSRC Programme Grant, MEMPHIS, EP/K0039761/1.
Tyagi, Anil K; Randolph, Theodore W; Dong, Aichun; Maloney, Kevin M; Hitscherich, Carl; Carpenter, John F
2009-01-01
This study investigated factors associated with vial filling with a positive displacement piston pump leading to formation of protein particles in a formulation of an IgG. We hypothesized that nanoparticles shed from the pump's solution-contact surfaces nucleated protein aggregation and particle formation. Vials of IgG formulation filled at a clinical manufacturing site contained a few visible particles and about 100,000 particles (1.5-3 microm) per mL. In laboratory studies with the same model (National Instruments FUS-10) of pump, pumping of 20 mg/mL IgG formulation resulted in about 300,000 particles (1.5-3 microm) per mL. Pumping of protein-free formulation resulted in 13,000 particles (1.5-15 microm) per mL. More than 99% of the particles were 0.25-0.95 microm in size. Mixing of protein-free pumped solution with an equal volume of 40 mg/mL IgG resulted in 300,000 particles (1.5-15 microm) per mL. Also, mixing IgG formulation with 30,000/mL stainless steel nanoparticles resulted in formation of 30,000 protein microparticles (1.5-15 microm) per mL. Infrared spectroscopy showed that secondary structure of IgG in microparticles formed by pumping or mixing with steel nanoparticles was minimally perturbed. Our results document that nanoparticles of foreign materials shed by pumps can serve as heterogeneous nuclei for formation of protein microparticles. (c) 2008 Wiley-Liss, Inc. and the American Pharmacists Association
MacLennan, Donald A.; Turner, Brian P.; Gitsevich, Aleksandr; Bass, Gary K.; Dolan, James T.; Kipling, Kent; Kirkpatrick, Douglas A.; Leng, Yongzhang; Levin, Izrail; Roy, Robert J.; Shanks, Bruce; Smith, Malcolm; Trimble, William C.; Tsai, Peter
2001-01-01
A jacketed lamp bulb envelope includes a ceramic cup having an open end and a partially closed end, the partially closed end defining an aperture, a lamp bulb positioned inside the ceramic cup abutting the aperture, and a reflective ceramic material at least partially covering a portion of the bulb not abutting the aperture. The reflective ceramic material may substantially fill an interior volume of the ceramic cup not occupied by the bulb. The ceramic cup may include a structural feature for aiding in alignment of the jacketed lamp bulb envelope in a lamp. The ceramic cup may include an external flange about a periphery thereof. One example of a jacketed lamp bulb envelope includes a ceramic cup having an open end and a closed end, a ceramic washer covering the open end of the ceramic cup, the washer defining an aperture therethrough, a lamp bulb positioned inside the ceramic cup abutting the aperture, and a reflective ceramic material filling an interior volume of the ceramic cup not occupied by the bulb. A method of packing a jacketed lamp bulb envelope of the type comprising a ceramic cup with a lamp bulb disposed therein includes the steps of filling the ceramic cup with a flowable slurry of reflective material, and applying centrifugal force to the cup to pack the reflective material therein.
Feast to famine: Sediment supply control on Laramide basin fill
NASA Astrophysics Data System (ADS)
Carroll, Alan R.; Chetel, Lauren M.; Elliot Smith, M.
2006-03-01
Erosion of Laramide-style uplifts in the western United States exerted an important first-order influence on Paleogene sedimentation by controlling sediment supply rates to adjacent closed basins. During the latest Cretaceous through Paleocene, these uplifts exposed thick intervals of mud-rich Upper Cretaceous foreland basin fill, which was quickly eroded and redeposited. Cretaceous sedimentary lithologies dominate Paleocene conglomerate clast compositions, and the volume of eroded foreland basin strata is approximately twice the volume of preserved Paleocene basin fill. As a result of this sediment oversupply, clastic alluvial and paludal facies dominate Paleocene strata, and are associated with relatively shallow and ephemeral freshwater lake facies. In contrast, large, long-lived, carbonate-producing lakes occupied several of the basins during the Eocene. Basement-derived clasts (granite, quartzite, and other metamorphic rocks) simultaneously became abundant in lower Eocene conglomerate. We propose that Eocene lakes developed primarily due to exposure of erosion-resistant lithologies within cores of Laramide uplifts. The resultant decrease in erosion rate starved adjacent basins of sediment, allowing the widespread and prolonged deposition of organic-rich lacustrine mudstone. These observations suggest that geomorphic evolution of the surrounding landscape should be considered as a potentially important influence on sedimentation in many other interior basins, in addition to more conventionally interpreted tectonic and climatic controls.
Hsiao, Hui-Yi; Yang, Shu-Rui; Brey, Eric M.; Chu, I-Ming
2016-01-01
Background: The application of bone tissue engineering for repairing bone defects has gradually shown some satisfactory progress. One of the concerns raising scientific attention is the poor supply of growth factors. A number of growth factor delivery approaches have been developed for promoting bone formation. However, there is no systematic comparison of those approaches on efficiency of neobone formation. In this study, the approaches using periosteum, direct supply of growth factors, or gene transfection of growth factors were evaluated to determine the osteogenic capacity on the repair of bone defect. Methods: In total, 42 male 21-week-old Sprague-Dawley rats weighing 250 to 400 g were used as the bone defect model to evaluate the bone repair efficiency. Various tissue engineered constructs of poly(ethylene glycol)-poly(l-lactic acid) (PEG-PLLA) copolymer hydrogel with periosteum, with external supply of bone morphogenetic protein-2 (BMP2), or with BMP2-transfected bone marrow–derived mesenchymal stem cells (BMMSCs) were filled in a 7-mm bone defect region. Animals were euthanized at 3 months, and the hydrogel constructs were harvested. The evaluation with histological staining and radiography analysis were performed for the volume of new bone formation. Results: The PEG-PLLA scaffold with BMMSCs promotes bone regeneration with the addition of periosteum. The group with BMP2-transfected BMMSCs demonstrated the largest volume of new bone among all the testing groups. Conclusions: Altogether, the results of this study provide the evidence that the combination of PEG-PLLA hydrogels with BMMSCs and sustained delivery of BMP2 resulted in the maximal bone regeneration. PMID:27622106
A Survey of Fuel and Energy Information Sources: Volume II
... con"",,, alld r~~i~~1' ,rl~'~~~i!~S' than who.ld Tau! ... I'ART of the year, plenoc fill out thio form. ... effect and na'ure of any impor- \\ant ware acale chanl ...
Code of Federal Regulations, 2013 CFR
2013-04-01
... damages consisting primarily of eroded shoulders, filled ditches and culverts, pavement settlement, mud..., not related to the increased traffic volumes, such as mowing, maintaining drainage, pavement signing... limited in ER reimbursement to the cost of a new facility to current design standards of comparable...
Code of Federal Regulations, 2010 CFR
2010-04-01
... damages consisting primarily of eroded shoulders, filled ditches and culverts, pavement settlement, mud..., not related to the increased traffic volumes, such as mowing, maintaining drainage, pavement signing... limited in ER reimbursement to the cost of a new facility to current design standards of comparable...
Code of Federal Regulations, 2014 CFR
2014-04-01
... damages consisting primarily of eroded shoulders, filled ditches and culverts, pavement settlement, mud..., not related to the increased traffic volumes, such as mowing, maintaining drainage, pavement signing... limited in ER reimbursement to the cost of a new facility to current design standards of comparable...
Code of Federal Regulations, 2012 CFR
2012-04-01
... damages consisting primarily of eroded shoulders, filled ditches and culverts, pavement settlement, mud..., not related to the increased traffic volumes, such as mowing, maintaining drainage, pavement signing... limited in ER reimbursement to the cost of a new facility to current design standards of comparable...
Code of Federal Regulations, 2011 CFR
2011-04-01
... damages consisting primarily of eroded shoulders, filled ditches and culverts, pavement settlement, mud..., not related to the increased traffic volumes, such as mowing, maintaining drainage, pavement signing... limited in ER reimbursement to the cost of a new facility to current design standards of comparable...
Brown, J.G.
1989-01-01
The San Carlos Indian Reservation includes about 2,900 sq mi in east- central Arizona. Relatively impermeable pre-Tertiary rocks are exposed in about 23% of the reservation and underlie water-bearing Tertiary and quaternary basin fill and Quaternary stream alluvium in much of the southern part of the reservation. About 9,000 members of the San Carlos Apache Tribe live on the reservation and rely on groundwater to meet public supply, irrigation, and other needs. Basin fill is widespread in the valley of the San Carlos and Gila Rivers and consists of fine sand, silt, limestone, clay, and pyroclastic volcanics that may attain a total maximum thickness of more than 3,200 ft in the reservation. Quaternary stream alluvium overlies the basin fill along many streams and washes. Stream alluvium consists of poorly sorted, unconsolidated, gravelly, muddy, sand; and sandy gravel and reaches a maximum thickness of 100 ft along the San Carlos and Gila Rivers. The volume of recoverable water stored in the basin fill to a depth of 1,200 ft is estimated to be about 20 million acre-ft. The volume of recoverable water stored in the stream alluvium on the reservation is estimated to be more than 100,000 acre-ft. The stream alluvium along the San Carlos River supplies most of the water used for drinking. Water throughout much of the reservation is suitable for most uses except for that in the alluvium along the Gila River, which contains large concentrations of dissolved solids. (USGS)
NASA LeRC's Acoustic Fill Effect Test Program and Results
NASA Technical Reports Server (NTRS)
Hughes, William O.; Mcnelis, Mark E.; Manning, Jerome E.
1994-01-01
NASA Lewis Research Center, in conjunction with General Dynamics Space Systems Division, has performed a test program to investigate the acoustic fill effect for an unblanketed payload fairing for a variety of payload simulators. This paper will discuss this test program and fill factor test data, and make comparisons with theoretical predictions. This paper will also address the NASA acoustic fill effect standard which was verified from the test data analysis.
EVALUATION OF RIGHT AND LEFT VENTRICULAR DIASTOLIC FILLING
Pasipoularides, Ares
2013-01-01
A conceptual fluid-dynamics framework for diastolic filling is developed. The convective deceleration load (CDL) is identified as an important determinant of ventricular inflow during the E-wave (A-wave) upstroke. Convective deceleration occurs as blood moves from the inflow anulus through larger-area cross-sections toward the expanding walls. Chamber dilatation underlies previously unrecognized alterations in intraventricular flow dynamics. The larger the chamber, the larger become the endocardial surface and the CDL. CDL magnitude affects strongly the attainable E-wave (A-wave) peak. This underlies the concept of diastolic ventriculoannular disproportion. Large vortices, whose strength decreases with chamber dilatation, ensue after the E-wave peak and impound inflow kinetic energy, averting an inflow-impeding, convective Bernoulli pressure-rise. This reduces the CDL by a variable extent depending on vortical intensity. Accordingly, the filling vortex facilitates filling to varying degrees, depending on chamber volume. The new framework provides stimulus for functional genomics research, aimed at new insights into ventricular remodeling. PMID:23585308
Concrete filled steel pipe inspection using electro magnetic acoustic transducer (EMAT)
NASA Astrophysics Data System (ADS)
Na, Won-Bae; Kundu, Tribikram; Ryu, Yeon-Sun; Kim, Jeong-Tae
2005-05-01
Concrete-filled steel pipes are usually exposed in hostile environments such as seawater and deicing materials. The outside corrosion of the steel pipe can reduce the wall thickness and the corrosion-induced delamination of internal concrete can increase internal volume or pressure. In addition, the void that can possibly exist in the pipe reduces the bending resistance. To avoid structural failure due to this type of deterioration, appropriate inspection and repair techniques are to be developed. Guided wave techniques have strong potentials for this kind of inspection because of long-distance inspection capability. Among different transducer-coupling mechanism, electro-magnetic acoustic transducers (EMATs) give relatively consistent results in comparison to piezoelectric transducers since they do not need any couplant. In this study EMATs are used for transmitting and receiving cylindrical guided waves through concrete-filled steel pipes. Through time history curves and wavelet transform, it is shown that EMAT-generated cylindrical guided wave techniques have good potential for the interface inspection of concrete-filled steel pipes.
Dynamics of a grain-filled ball on a vibrating plate.
Pacheco-Vázquez, F; Ludewig, F; Dorbolo, S
2014-09-12
We study experimentally how the bouncing dynamics of a hollow ball on a vibrating plate is modified when it is partially filled with liquid or grains. Whereas empty and liquid-filled balls display a dominant chaotic dynamics, a ball with grains exhibits a rich variety of stationary states, determined by the grain size and filling volume. In the collisional regime, i.e., when the energy injected to the system is mainly dissipated by interparticle collisions, an unexpected period-1 orbit appears independently of the vibration conditions, over a wide range. This is a self-regulated state driven by the formation and collapse of a granular gas within the ball during one cycle. In the frictional regime (dissipation dominated by friction), the grains move collectively and generate different patterns and steady modes: oscillons, waves, period doubling, etc. From a phase diagram and a geometrical analysis, we deduce that these modes are the result of a coupling (synchronization) between the vibrating plate frequency and the trajectory followed by the particles inside the cavity.
Dynamics of a Grain-Filled Ball on a Vibrating Plate
NASA Astrophysics Data System (ADS)
Pacheco-Vázquez, F.; Ludewig, F.; Dorbolo, S.
2014-09-01
We study experimentally how the bouncing dynamics of a hollow ball on a vibrating plate is modified when it is partially filled with liquid or grains. Whereas empty and liquid-filled balls display a dominant chaotic dynamics, a ball with grains exhibits a rich variety of stationary states, determined by the grain size and filling volume. In the collisional regime, i.e., when the energy injected to the system is mainly dissipated by interparticle collisions, an unexpected period-1 orbit appears independently of the vibration conditions, over a wide range. This is a self-regulated state driven by the formation and collapse of a granular gas within the ball during one cycle. In the frictional regime (dissipation dominated by friction), the grains move collectively and generate different patterns and steady modes: oscillons, waves, period doubling, etc. From a phase diagram and a geometrical analysis, we deduce that these modes are the result of a coupling (synchronization) between the vibrating plate frequency and the trajectory followed by the particles inside the cavity.
Effect of filling factor on photonic bandgap of chalcogenide photonic crystal
NASA Astrophysics Data System (ADS)
Singh, Rajpal; Suthar, B.; Bhargava, A.
2018-05-01
In the present work, the photonic band structure of 1-D chalcogenide photonic crystal of As2S3/air multilayered structure is calculated using the plane wave expansion method. The study is extended to investigate the effect of filling factor on the photonic bandgap. The increase of bandgap is explained in the study.
General analysis of slab lasers using geometrical optics.
Chung, Te-yuan; Bass, Michael
2007-02-01
A thorough and general geometrical optics analysis of a slab-shaped laser gain medium is presented. The length and thickness ratio is critical if one is to achieve the maximum utilization of absorbed pump power by the laser light in such a medium; e.g., the fill factor inside the slab is to be maximized. We point out that the conditions for a fill factor equal to 1, laser light entering and exiting parallel to the length of the slab, and Brewster angle incidence on the entrance and exit faces cannot all be satisfied at the same time. Deformed slabs are also studied. Deformation along the width direction of the largest surfaces is shown to significantly reduce the fill factor that is possible.
NASA Technical Reports Server (NTRS)
Moran, Matthew E.; Nyland, Ted W.
1992-01-01
A total of 38 hydrogen no-vent fill tests were performed in this test series using various size spray nozzles and a spray bar with different hole sizes in a 5 cubic foot receiver tank. Fill levels of 90 percent by volume or greater were achieved in 26 of the tests while maintaining a receiver tank pressure below 30 psia. Spray nozzles were mounted at the top of the tank, whereas, the spray bar was centered in the tank axially. The spray nozzle no-vent fills demonstrated tank pressure and temperature responses comparable to previous test series. Receiver tank pressure responses for the spray bar configuration were similar to the spray nozzle tests with the pressure initially rising rapidly, then leveling off as vapor condenses onto the discharging liquid streams, and finally ramping up near the end of the test due to ullage compression. Both liquid injection techniques tested were capable of filling the receiver tank to 90 percent under variable test conditions. Comparisons between the spray nozzle and spray bar configurations for well matched test conditions indicate the spray nozzle injection technique is more effective in minimizing the receiving tank pressure throughout a no-vent fill compared to the spray bar under normal gravity conditions.
Wave Overtopping of a Barrier Beach
NASA Astrophysics Data System (ADS)
Thornton, E. B.; Laudier, N.; Macmahan, J. H.
2009-12-01
The rate of wave overtopping of a barrier beach is measured and modeled as a first step in modeling the breaching of a beach impounding an ephemeral river. Unique rate of wave overtopping data are obtained from the measure of the Carmel River, California, lagoon filling during a time when the lagoon is closed-off and there is no river inflow. Volume changes are calculated from measured lagoon height changes owing to wave overtopping by a stage-volume curve, then center differenced and averaged to provide volume rates of change in the lagoon. Wave height and period are obtained from CDIP MOPS directional wave spectra data in 15m fronting the beach. Beach morphology was measured by GPS walking surveys and interpolated for beach slopes and berm heights. Three empirical overtopping models by van der Meer and Janssen (1995), Hedges and Reis (1998) and Pullen et al. (2007) with differing parameterizations on wave height, period and beach slope and calibrated using extensive laboratory data obtained over plane, impermeable beaches are compared with the data. In addition, the run-up model by Stockdon et al. (2006) based on field data is examined. Three wave overtopping storm events are considered when morphology data were available less than 2 weeks prior to the event. The models are tuned to fit the data using a reduction factor to account for beach permeability, berm characteristics, non-normal wave incidence and surface roughness influence. It is concluded that the Stockdon et al. (2006) model underestimates run-up as no overtopping is predicted with this model. The three empirical overtopping models behaved similarly well with regression coefficients ranging 0.72 to 0.86 using a reasonable range of reduction factors 0.66 - 0.81 with an average of 0.74.
Mohamad, N; Zuharah, W F
2014-03-01
Toxorhynchites splendens larvae are a natural predator of dengue vector mosquito larvae, Aedes albopictus. This study was carried out to evaluate the predation rate of Tx. splendens third instar larvae on Ae. albopictus larvae in 24 h. Each predator was offered prey at a density between 10 to 50 individuals. Predation rate of Tx. splendens were also tested with two manipulated factors; various types of container and different water volumes. The experiment was evaluated in man-made containers (tin cans, plastic drinking glasses and rubber tires) and natural container (bamboo stumps) which were filled with different water volumes (full, half full, 1/4 full, and 1/8 full). The prey density and the characteristics of the container were found as significant factors which influence the predation rate of Tx. splendens. The predator consumed significantly more prey at higher prey densities (40 and 50 preys) compared to the lowest density (10 preys) (F=3.935, df=4, p=0.008). The results showed significantly higher consumption in horizontal shaped container of rubber tire than in vertical shape of bamboo stumps (F=3.100, df=3, p=0.029). However, the water volume had no significant effect on predation rate of Tx. splendens (F=1.736, df=3, p=0.162). We generally suggest that Tx. splendens is best to be released in discarded tires or any other containers with horizontal shape design with wide opening since Tx. splendens can become more effective in searching prey in this type of container design. This predator is also a suitable biocontrol candidates to be introduced either in wet and dry seasons in Malaysia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bondar, M.L., E-mail: m.bondar@erasmusmc.nl; Hoogeman, M.S.; Mens, J.W.
2012-08-01
Purpose: To design and evaluate individualized nonadaptive and online-adaptive strategies based on a pretreatment established motion model for the highly deformable target volume in cervical cancer patients. Methods and Materials: For 14 patients, nine to ten variable bladder filling computed tomography (CT) scans were acquired at pretreatment and after 40 Gy. Individualized model-based internal target volumes (mbITVs) accounting for the cervix and uterus motion due to bladder volume changes were generated by using a motion-model constructed from two pretreatment CT scans (full and empty bladder). Two individualized strategies were designed: a nonadaptive strategy, using an mbITV accounting for the full-rangemore » of bladder volume changes throughout the treatment; and an online-adaptive strategy, using mbITVs of bladder volume subranges to construct a library of plans. The latter adapts the treatment online by selecting the plan-of-the-day from the library based on the measured bladder volume. The individualized strategies were evaluated by the seven to eight CT scans not used for mbITVs construction, and compared with a population-based approach. Geometric uniform margins around planning cervix-uterus and mbITVs were determined to ensure adequate coverage. For each strategy, the percentage of the cervix-uterus, bladder, and rectum volumes inside the planning target volume (PTV), and the clinical target volume (CTV)-to-PTV volume (volume difference between PTV and CTV) were calculated. Results: The margin for the population-based approach was 38 mm and for the individualized strategies was 7 to 10 mm. Compared with the population-based approach, the individualized nonadaptive strategy decreased the CTV-to-PTV volume by 48% {+-} 6% and the percentage of bladder and rectum inside the PTV by 5% to 45% and 26% to 74% (p < 0.001), respectively. Replacing the individualized nonadaptive strategy by an online-adaptive, two-plan library further decreased the percentage of bladder and rectum inside the PTV (0% to 10% and -1% to 9%; p < 0.004) and the CTV-to-PTV volume (4-96 ml). Conclusions: Compared with population-based margins, an individualized PTV results in better organ-at-risk sparing. Online-adaptive radiotherapy further improves organ-at-risk sparing.« less
Compact cell-centered discretization stencils at fine-coarse block structured grid interfaces
NASA Astrophysics Data System (ADS)
Pletzer, Alexander; Jamroz, Ben; Crockett, Robert; Sides, Scott
2014-03-01
Different strategies for coupling fine-coarse grid patches are explored in the context of the adaptive mesh refinement (AMR) method. We show that applying linear interpolation to fill in the fine grid ghost values can produce a finite volume stencil of comparable accuracy to quadratic interpolation provided the cell volumes are adjusted. The volume of fine cells expands whereas the volume of neighboring coarse cells contracts. The amount by which the cells contract/expand depends on whether the interface is a face, an edge, or a corner. It is shown that quadratic or better interpolation is required when the conductivity is spatially varying, anisotropic, the refinement ratio is other than two, or when the fine-coarse interface is concave.
Adaptive kernel regression for freehand 3D ultrasound reconstruction
NASA Astrophysics Data System (ADS)
Alshalalfah, Abdel-Latif; Daoud, Mohammad I.; Al-Najar, Mahasen
2017-03-01
Freehand three-dimensional (3D) ultrasound imaging enables low-cost and flexible 3D scanning of arbitrary-shaped organs, where the operator can freely move a two-dimensional (2D) ultrasound probe to acquire a sequence of tracked cross-sectional images of the anatomy. Often, the acquired 2D ultrasound images are irregularly and sparsely distributed in the 3D space. Several 3D reconstruction algorithms have been proposed to synthesize 3D ultrasound volumes based on the acquired 2D images. A challenging task during the reconstruction process is to preserve the texture patterns in the synthesized volume and ensure that all gaps in the volume are correctly filled. This paper presents an adaptive kernel regression algorithm that can effectively reconstruct high-quality freehand 3D ultrasound volumes. The algorithm employs a kernel regression model that enables nonparametric interpolation of the voxel gray-level values. The kernel size of the regression model is adaptively adjusted based on the characteristics of the voxel that is being interpolated. In particular, when the algorithm is employed to interpolate a voxel located in a region with dense ultrasound data samples, the size of the kernel is reduced to preserve the texture patterns. On the other hand, the size of the kernel is increased in areas that include large gaps to enable effective gap filling. The performance of the proposed algorithm was compared with seven previous interpolation approaches by synthesizing freehand 3D ultrasound volumes of a benign breast tumor. The experimental results show that the proposed algorithm outperforms the other interpolation approaches.
Azim, A A; Griggs, J A; Huang, G T-J
2016-01-01
To determine factors that may influence treatment outcome and healing time following root canal treatment. Root filled and restored teeth by pre-doctoral students were included in this study. Teeth/roots were followed-up regularly, and treatment outcome was evaluated at every follow-up appointment (healed, healing, uncertain or unsatisfactory). Host (age, immune condition, pulp/periapical diagnosis, tooth/root type, location and anatomy) and treatment factors (master apical file size, apical extension, voids and density of root filling) were recorded from patient dental records. Univariate, bivariate and multivariate analyses were performed to determine the impact of the factors on treatment outcomes and healing times. A total of 422 roots from 291 teeth met the inclusion criteria with a mean follow-up period of 2 years. The preoperative pulp condition, procedural errors during treatment, apical extension and density of root fillings significantly affected the treatment outcome. The average time required for a periapical lesion to heal was 11.78 months. The healing time increased in patients with compromised healing, patients older than 40 years, roots with Weine type II root canal systems, root canal systems prepared to a master apical file size <35, and roots with overextended fillings (P < 0.1). Multiple host and treatment factors affected the healing time and outcome of root canal treatment. Follow-up protocols should consider these factors before concluding the treatment outcome: patient's age, immune condition, as well as roots with overextended fillings, root canal systems with smaller apical preparations (size <35) or roots with complex canal systems. Intervention may be recommended if the treatment quality was inadequate or if patients became symptomatic. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Koizumi, Koji; Charles, Ted; de Keyser, Hendrik
Phenolic Molding Compounds continue to exhibit well balanced properties such as heat resistance, chemical resistance, dimensional stability, and creep resistance. They are widely applied in electrical, appliance, small engine, commutator, and automotive applications. As the focus of the automotive industry is weight reduction for greater fuel efficiency, phenolic molding compounds become appealing alternatives to metals. Current market volumes and trends, formulation components and its impact on properties, and a review of common manufacturing methods are presented. Molding processes as well as unique advanced techniques such as high temperature molding, live sprue, and injection/compression technique provide additional benefits in improving the performance characterisitics of phenolic molding compounds. Of special interest are descriptions of some of the latest innovations in automotive components, such as the phenolic intake manifold and valve block for dual clutch transmissions. The chapter also characterizes the most recent developments in new materials, including long glass phenolic molding compounds and carbon fiber reinforced phenolic molding compounds exhibiting a 10-20-fold increase in Charpy impact strength when compared to short fiber filled materials. The role of fatigue testing and fatigue fracture behavior presents some insight into long-term reliability and durability of glass-filled phenolic molding compounds. A section on new technology outlines the important factors to consider in modeling phenolic parts by finite element analysis and flow simulation.
NASA Technical Reports Server (NTRS)
West, J. B.; Elliott, A. R.; Guy, H. J.; Prisk, G. K.
1997-01-01
The lung is exquisitely sensitive to gravity, and so it is of interest to know how its function is altered in the weightlessness of space. Studies on National Aeronautics and Space Administration (NASA) Spacelabs during the last 4 years have provided the first comprehensive data on the extensive changes in pulmonary function that occur in sustained microgravity. Measurements of pulmonary function were made on astronauts during space shuttle flights lasting 9 and 14 days and were compared with extensive ground-based measurements before and after the flights. Compared with preflight measurements, cardiac output increased by 18% during space flight, and stroke volume increased by 46%. Paradoxically, the increase in stroke volume occurred in the face of reductions in central venous pressure and circulating blood volume. Diffusing capacity increased by 28%, and the increase in the diffusing capacity of the alveolar membrane was unexpectedly large based on findings in normal gravity. The change in the alveolar membrane may reflect the effects of uniform filling of the pulmonary capillary bed. Distributions of blood flow and ventilation throughout the lung were more uniform in space, but some unevenness remained, indicating the importance of nongravitational factors. A surprising finding was that airway closing volume was approximately the same in microgravity and in normal gravity, emphasizing the importance of mechanical properties of the airways in determining whether they close. Residual volume was unexpectedly reduced by 18% in microgravity, possibly because of uniform alveolar expansion. The findings indicate that pulmonary function is greatly altered in microgravity, but none of the changes observed so far will apparently limit long-term space flight. In addition, the data help to clarify how gravity affects pulmonary function in the normal gravity environment on Earth.
Roth, C; Winter, G; Lee, G
2001-09-01
The use of a novel microbalance (Christ) technique to monitor continuously the weight loss of a vial standing on a shelf of a freeze-dryer has been investigated. The drying rates of the following aqueous solutions were measured during the primary drying phase of a complete freeze-drying cycle: sucrose (75 mg/mL, 2.5-mL fill volume), sucrose and phenylalanine (1:0.2 by weight, 75 mg/mL, 2.5-mL fill volume), and mannitol (75mg/mL, 2.5-mL fill volume). The microbalance yields the cumulative water loss, m(cu) in grams, and the momentary drying rate, Deltam(cu)/Deltat in mg/10 min, of the frozen cake. The momentary drying rate curves were especially useful for examining how Deltam(cu)/Deltat changes with time during primary drying. Initially, Deltam(cu)/Deltat rises to a sharp maximum and then decreases in a fashion depending on shelf temperature, chamber pressure, and the nature of the substance being dried. Different drying behavior was observed for the sucrose and sucrose/phenylalanine systems, which was attributed to the presence of crystalline phenylalanine in the amorphous sucrose. At low shelf-temperature (-24 degrees C) the crystalline mannitol showed lower Deltam(cu)/Deltat than with either sucrose or sucrose/phenylalanine. The balance could also detect differences in Deltam(cu)/Deltat when using different freezing protocols. "Slow" and "moderate" freezing protocols gave similar drying behavior, but "rapid" freezing in liquid nitrogen produced greatly altered drying rate and internal cake morphology. The balance also could be used to detect the endpoint of primary drying. Different endpoint criteria and their influence on final dried cake properties were examined. Copyright 2001 Wiley-Liss, Inc. and the American Pharmaceutical Association
Iwamatsu, Masao
2016-09-20
The free-energy barrier of filling a spherical cavity having an inner wall of various wettabilities is studied. The morphology and free energy of a lens-shaped droplet are determined from the minimum of the free energy. The effect of line tension on the free energy is also studied. Then, the equilibrium contact angle of the droplet is determined from the generalized Young's equation. By increasing the droplet volume within the spherical cavity, the droplet morphology changes from spherical with an equilibrium contact angle of 180° to a lens with a convex meniscus, where the morphological complete drying transition occurs. By further increasing the droplet volume, the meniscus changes from convex to concave. Then, the lens-shaped droplet with concave meniscus spreads over the whole inner wall, resulting in an equilibrium contact angle of 0° to leave a spherical bubble, where the morphological complete wetting transition occurs. Finally, the whole cavity is filled with liquid. The free energy shows a barrier from complete drying to complete wetting as a function of droplet volume, which corresponds to the energy barrier between the Cassie and Wenzel states of the superhydrophobic surface with spherical cavities. The free-energy maximum occurs when the meniscus of the droplet becomes flat, and it is given by an analytic formula. The effect of line tension is expressed by the scaled line tension, and this effect is largest at the free-energy maximum. The positive line tension increases the free-energy maximum, which thus increases the stability of the Cassie superhydrophobic state, whereas the negative line tension destabilizes the superhydrophobic state.
Okwuosa, Tochukwu C; Soares, Cindy; Gollwitzer, Verena; Habashy, Rober; Timmins, Peter; Alhnan, Mohamed A
2018-06-15
A method for the production of liquid capsules with the potential of modifying drug dose and release is presented. For the first time, the co-ordinated use of fused deposition modelling (FDM), 3D printing and liquid dispensing to fabricate individualised dosage form on demand in a fully automated fashion has been demonstrated. Polymethacrylate shells (Eudragit EPO and RL) for immediate and extended release were fabricated using FDM 3D printing and simultaneously filled using a computer-controlled liquid dispenser loaded with model drug solution (theophylline) or suspension (dipyridamole). The impact of printing modes: simultaneous shell printing and filling (single-phase) or sequential 3D printing of shell bottom, filling and shell cap (multi-phase), nozzle size, syringe volume, and shell structure has been reported. The use of shell thickness of 1.6 mm, and concentric architecture allowed successful containment of liquid core whilst maintaining the release properties of the 3D printed liquid capsule. The linear relationship between the theoretical and the actual volumes from the dispenser reflected its potential for accurate dosing (R 2 = 0.9985). Modifying the shell thickness of Eudragit RL capsule allowed a controlled extended drug release without the need for formulation change. Owing to its low cost and versatility, this approach can be adapted to wide spectrum of liquid formulations such as small and large molecule solutions and obviate the need for compatibility with the high temperature of FDM 3D printing process. In a clinical setting, health care staff will be able to instantly manufacture in small volumes liquid capsules with individualised dose contents and release pattern in response to specific patient's needs. Copyright © 2018 Elsevier B.V. All rights reserved.
Azizan, Amizon; Büchs, Jochen
2017-01-01
Biotechnological development in shake flask necessitates vital engineering parameters e.g. volumetric power input, mixing time, gas liquid mass transfer coefficient, hydromechanical stress and effective shear rate. Determination and optimization of these parameters through experiments are labor-intensive and time-consuming. Computational Fluid Dynamics (CFD) provides the ability to predict and validate these parameters in bioprocess engineering. This work provides ample experimental data which are easily accessible for future validations to represent the hydrodynamics of the fluid flow in the shake flask. A non-invasive measuring technique using an optical fluorescence method was developed for shake flasks containing a fluorescent solution with a waterlike viscosity at varying filling volume (V L = 15 to 40 mL) and shaking frequency ( n = 150 to 450 rpm) at a constant shaking diameter (d o = 25 mm). The method detected the leading edge (LB) and tail of the rotating bulk liquid (TB) relative to the direction of the centrifugal acceleration at varying circumferential heights from the base of the shake flask. The determined LB and TB points were translated into three-dimensional (3D) circumferential liquid distribution plots. The maximum liquid height (H max ) of the bulk liquid increased with increasing filling volume and shaking frequency of the shaking flask, as expected. The toroidal shapes of LB and TB are clearly asymmetrical and the measured TB differed by the elongation of the liquid particularly towards the torus part of the shake flask. The 3D liquid distribution data collected at varying filling volume and shaking frequency, comprising of LB and TB values relative to the direction of the centrifugal acceleration are essential for validating future numerical solutions using CFD to predict vital engineering parameters in shake flask.
Verges, Ramona; Giraldo, Alexandra; Seoane, Alejandro; Toral, Elisabet; Ruiz, M Carmen; Pons, Ariadna; Giralt, Jordi
2018-01-01
To find out whether the internal target volume (ITV) vaginal procedure ensures dosimetric coverage during intensity-modulated radiation therapy (IMRT) of post-operative gynaecological tumours without instructions on rectal filling. The ITV vaginal procedure does not necessarily include all movements of the bladder, and does not include changes in the rectal volume. We should know if the vaginal ITV is a useful tool in maintaining CTV coverage during treatment. A retrospective analysis of 24 patients treated between July 2012 and July 2014 with adjuvant IMRT for gynaecological cancer. All patients underwent empty and full bladder CT on simulation (CT-planning) and three weeks later (CT-control). ITV displacement was measured and the 3D vector was calculated. ITV coverage was then evaluated by comparing the volume covered by the prescription isodose on both CT's. Patients were asked to have full bladder but they did not follow recommendations for the rectum. The mean 3D vector was 0.64 ± 0.32 cm (0.09-1.30). The mean ITV coverage loss was 5.8 ± 5.7% (0-20.2). We found a significant positive correlation between the 3D vector and the loss of coverage (Pearson correlation, r = 0.493, 95% CI: 0.111-0.748, p = 0.0144). We did not find any significant correlation between the bladder and rectal parameters with the 3D vector and loss of dosimetric coverage. We found a trend between the maximum rectal diameter in CT-planning and 3D vector ( r = 0.400, 95% CI: -0.004 to 0.692, p = 0.0529). ITV vaginal procedure contributed to ensuring a good dose coverage without instructions on rectal filling.
An investigation of the critical liquid-vapor properties of dilute KCl solutions
Potter, R.W.; Babcock, R.S.; Czamanske, G.K.
1976-01-01
The three parameters that define the critical point, temperature, pressure, and volume have been experimentally determined by means of filling studies in a platinum-lined system for five KCl solutions ranging from 0.006 to 0.568 m. The platinum-lined vessels were used to overcome the problems with corrosion experienced by earlier workers. The critical temperature (tc), pressure (Pc), and volume (Vc) were found to fit the equations {Mathematical expression} from infinite dilution to 1.0 m. ?? 1976 Plenum Publishing Corporation.
Food-web models predict species abundances in response to habitat change.
Gotelli, Nicholas J; Ellison, Aaron M
2006-10-01
Plant and animal population sizes inevitably change following habitat loss, but the mechanisms underlying these changes are poorly understood. We experimentally altered habitat volume and eliminated top trophic levels of the food web of invertebrates that inhabit rain-filled leaves of the carnivorous pitcher plant Sarracenia purpurea. Path models that incorporated food-web structure better predicted population sizes of food-web constituents than did simple keystone species models, models that included only autecological responses to habitat volume, or models including both food-web structure and habitat volume. These results provide the first experimental confirmation that trophic structure can determine species abundances in the face of habitat loss.
NASA Technical Reports Server (NTRS)
1990-01-01
NASA's Office of Aeronautics and Space Technology conducted a workshop on technology for space station evolution 16-19 Jan. 1990. The purpose of the workshop was to collect and clarify Space Station Freedom technology requirements for evolution and to describe technologies that can potentially fill those requirements. These proceedings are organized into an Executive Summary and Overview and five volumes containing the Technology Discipline Presentations. Volume 2 consists of the technology discipline sections for the Data Management System and the Environmental Control and Life Support Systems. For each technology discipline, there is a Level 3 subsystem description, along with the invited papers.
Technology for Space Station Evolution. Volume 3: EVA/Manned Systems/Fluid Management System
NASA Technical Reports Server (NTRS)
1990-01-01
NASA's Office of Aeronautics and Space Technology (OAST) conducted a workshop on technology for space station evolution 16-19 Jan. 1990 in Dallas, Texas. The purpose of this workshop was to collect and clarify Space Station Freedom technology requirements for evolution and to describe technologies that can potentially fill those requirements. These proceedings are organized into an Executive Summary and Overview and five volumes containing the Technology Discipline Presentations. Volume 3 consists of the technology discipline sections for Extravehicular Activity/Manned Systems and the Fluid Management System. For each technology discipline, there is a Level 3 subsystem description, along with the papers.
Strength of laser welded joints of polypropylene composites
NASA Astrophysics Data System (ADS)
Votrubec, V.; Hisem, P.; Vinšová, L.; Lukášová, V.
2017-11-01
This paper deals with experimental tests of laser welded polypropylene composites. Polymers, such as polypropylene, are often filled with fibres in order to increase their mechanical properties. The welding procedure can also influence material properties nearby weld joints. Therefore the strength of weld joints is lower than strength of primary materials. This effect is proved by realized shear tests. Polymer specimens were filled with 20 % and 40 % of glass fibres and all possible combinations of specimens were welded for experiments. There is also discussed influence of volume fraction of glass fibres in polypropylene on the strength of weld joint.
Partially filled electrodes for digital microfluidic devices
NASA Astrophysics Data System (ADS)
Pyne, D. G.; Salman, W. M.; Abdelgawad, M.; Sun, Y.
2013-07-01
As digital microfluidics technology evolves, the need for integrating additional elements (e.g., sensing/detection and heating elements) on the electrode increases. Consequently, electrode area for droplet actuation is reduced to create space for accommodating these additional elements, which undesirably affects force generation. Electrodes cannot simply be scaled larger to compensate for this loss of force, as this would also increase droplet volume and thereby compromise the advantages thought in miniaturization. Here, we present a study evaluating, numerically with preliminary experimental verification, different partially filled electrode designs and suggesting designs that combine high actuation forces with a large reduction in electrode area.
Silicon deposition in nanopores using a liquid precursor.
Masuda, Takashi; Tatsuda, Narihito; Yano, Kazuhisa; Shimoda, Tatsuya
2016-11-22
Techniques for depositing silicon into nanosized spaces are vital for the further scaling down of next-generation devices in the semiconductor industry. In this study, we filled silicon into 3.5-nm-diameter nanopores with an aspect ratio of 70 by exploiting thermodynamic behaviour based on the van der Waals energy of vaporized cyclopentasilane (CPS). We originally synthesized CPS as a liquid precursor for semiconducting silicon. Here we used CPS as a gas source in thermal chemical vapour deposition under atmospheric pressure because vaporized CPS can fill nanopores spontaneously. Our estimation of the free energy of CPS based on Lifshitz van der Waals theory clarified the filling mechanism, where CPS vapour in the nanopores readily undergoes capillary condensation because of its large molar volume compared to those of other vapours such as water, toluene, silane, and disilane. Consequently, a liquid-specific feature was observed during the deposition process; specifically, condensed CPS penetrated into the nanopores spontaneously via capillary force. The CPS that filled the nanopores was then transformed into solid silicon by thermal decomposition at 400 °C. The developed method is expected to be used as a nanoscale silicon filling technology, which is critical for the fabrication of future quantum scale silicon devices.
Silicon deposition in nanopores using a liquid precursor
NASA Astrophysics Data System (ADS)
Masuda, Takashi; Tatsuda, Narihito; Yano, Kazuhisa; Shimoda, Tatsuya
2016-11-01
Techniques for depositing silicon into nanosized spaces are vital for the further scaling down of next-generation devices in the semiconductor industry. In this study, we filled silicon into 3.5-nm-diameter nanopores with an aspect ratio of 70 by exploiting thermodynamic behaviour based on the van der Waals energy of vaporized cyclopentasilane (CPS). We originally synthesized CPS as a liquid precursor for semiconducting silicon. Here we used CPS as a gas source in thermal chemical vapour deposition under atmospheric pressure because vaporized CPS can fill nanopores spontaneously. Our estimation of the free energy of CPS based on Lifshitz van der Waals theory clarified the filling mechanism, where CPS vapour in the nanopores readily undergoes capillary condensation because of its large molar volume compared to those of other vapours such as water, toluene, silane, and disilane. Consequently, a liquid-specific feature was observed during the deposition process; specifically, condensed CPS penetrated into the nanopores spontaneously via capillary force. The CPS that filled the nanopores was then transformed into solid silicon by thermal decomposition at 400 °C. The developed method is expected to be used as a nanoscale silicon filling technology, which is critical for the fabrication of future quantum scale silicon devices.
An energy- and depth-dependent model for x-ray imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gallas, Brandon D.; Boswell, Jonathan S.; Badano, Aldo
In this paper, we model an x-ray imaging system, paying special attention to the energy- and depth-dependent characteristics of the inputs and interactions: x rays are polychromatic, interaction depth and conversion to optical photons is energy-dependent, optical scattering and the collection efficiency depend on the depth of interaction. The model we construct is a random function of the point process that begins with the distribution of x rays incident on the phosphor and ends with optical photons being detected by the active area of detector pixels to form an image. We show how the point-process representation can be used tomore » calculate the characteristic statistics of the model. We then simulate a Gd{sub 2}O{sub 2}S:Tb phosphor, estimate its characteristic statistics, and proceed with a signal-detection experiment to investigate the impact of the pixel fill factor on detecting spherical calcifications (the signal). The two extremes possible from this experiment are that SNR{sup 2} does not change with fill factor or changes in proportion to fill factor. In our results, the impact of fill factor is between these extremes, and depends on the diameter of the signal.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Foroudi, Farshad, E-mail: farshad.foroudi@petermac.org; Pham, Daniel; Bressel, Mathias
2013-05-01
Purpose: The use of image guidance protocols using soft tissue anatomy identification before treatment can reduce interfractional variation. This makes intrafraction clinical target volume (CTV) to planning target volume (PTV) changes more important, including those resulting from intrafraction bladder filling and motion. The purpose of this study was to investigate the required intrafraction margins for soft tissue image guidance from pretreatment and posttreatment volumetric imaging. Methods and Materials: Fifty patients with muscle-invasive bladder cancer (T2-T4) underwent an adaptive radiation therapy protocol using daily pretreatment cone beam computed tomography (CBCT) with weekly posttreatment CBCT. A total of 235 pairs of pretreatmentmore » and posttreatment CBCT images were retrospectively contoured by a single radiation oncologist (CBCT-CTV). The maximum bladder displacement was measured according to the patient's bony pelvis movement during treatment, intrafraction bladder filling, and bladder centroid motion. Results: The mean time between pretreatment and posttreatment CBCT was 13 minutes, 52 seconds (range, 7 min 52 sec to 30 min 56 sec). Taking into account patient motion, bladder centroid motion, and bladder filling, the required margins to cover intrafraction changes from pretreatment to posttreatment in the superior, inferior, right, left, anterior, and posterior were 1.25 cm (range, 1.19-1.50 cm), 0.67 cm (range, 0.58-1.12 cm), 0.74 cm (range, 0.59-0.94 cm), 0.73 cm (range, 0.51-1.00 cm), 1.20 cm (range, 0.85-1.32 cm), and 0.86 cm (range, 0.73-0.99), respectively. Small bladders on pretreatment imaging had relatively the largest increase in pretreatment to posttreatment volume. Conclusion: Intrafraction motion of the bladder based on pretreatment and posttreatment bladder imaging can be significant particularly in the anterior and superior directions. Patient motion, bladder centroid motion, and bladder filling all contribute to changes between pretreatment and posttreatment imaging. Asymmetric expansion of CTV to PTV should be considered. Care is required in using image-guided radiation therapy protocols that reduce CTV to PTV margins based only on daily pretreatment soft tissue position.« less
Dielectric properties of lung tissue as a function of air content.
Nopp, P; Rapp, E; Pfützner, H; Nakesch, H; Ruhsam, C
1993-06-01
Dielectric measurements were made on lung samples with different electrode systems in the frequency range 5 kHz-100 kHz. In the case of plate electrodes and spot electrodes, the effects of electrode polarization were partly corrected. An air filling factor F is defined, which is determined from the mass and volume of the sample. The results indicate that the electrical properties of lung tissue are highly dependent on the condition of the tissue. Furthermore they show that the conductivity sigma as well as the relative permittivity epsilon r decreases with increasing F. This is discussed using histological material. Using a simple theoretical model, the decrease of sigma and epsilon r is explained by the thinning of the alveolar walls as well as by the deformation of the epithelial cells and blood vessels through the expansion of the alveoli.
Fracture behavior of glass fiber reinforced polymer composite
DOE Office of Scientific and Technical Information (OSTI.GOV)
Avci, A.; Arikan, H.; Akdemir, A
2004-03-01
Chopped strand glass fiber reinforced particle-filled polymer composite beams with varying notch-to-depth ratios and different volume fractions of glass fibers were investigated in Mode I fracture using three-point bending tests. Effects of polyester resin content and glass fiber content on fracture behavior was also studied. Polyester resin contents were used 13.00%%, 14.75%, 16.50%, 18.00% and 19.50%, and glass fiber contents were 1% and 1.5% of the total weight of the polymer composite system. Flexural strength of the polymer composite increases with increase in polyester and fiber content. The critical stress intensity factor was determined by using several methods such asmore » initial notch depth method, compliance method and J-integral method. The values of K{sub IC} obtained from these methods were compared.« less
ERIC Educational Resources Information Center
Gardner, John, Ed.
2006-01-01
In most developed countries, the pursuit of reliable and valid means of assessing people's learning generates high volumes of published discourse and, not infrequently, dissent; the documentation on the various assessment policies, practices and theories could conceivably fill whole libraries. Some of the discourse and much of the dissent relate…
Mullins effect in a filled elastomer under uniaxial tension
Maiti, A.; Small, W.; Gee, R. H.; ...
2014-01-16
Modulus softening and permanent set in filled polymeric materials due to cyclic loading and unloading, commonly known as the Mullins effect, can have a significant impact on their use as support cushions. The quantitative analysis of such behavior is essential to ensure the effectiveness of such materials in long-term deployment. In this work we combine existing ideas of filler-induced modulus enhancement, strain amplification, and irreversible deformation within a simple non-Gaussian constitutive model to quantitatively interpret recent measurements on a relevant PDMS-based elastomeric cushion. Also, we find that the experimental stress-strain data is consistent with the picture that during stretching (loading)more » two effects take place simultaneously: (1) the physical constraints (entanglements) initially present in the polymer network get disentangled, thus leading to a gradual decrease in the effective cross-link density, and (2) the effective filler volume fraction gradually decreases with increasing strain due to the irreversible pulling out of an initially occluded volume of the soft polymer domain.« less
Relationship between sampling volume of primary serum tubes and spurious hemolysis.
Lippi, Giuseppe; Musa, Roberta; Battistelli, Luisita; Cervellin, Gianfranco
2012-01-01
We planned a study to establish whether spurious hemolysis may be present in low volume tubes or partially filled tubes. Four serum tubes were collected in sequence from 20 healthy volunteers, i.e., 4.0 mL, 13 x 75 mm (discard tube), 6.0 mL, 13 x 100 mm half-filled, 4.0 mL, 13 x 75 mm full-draw and 6.0 mL, 13 x 100 mm full-draw. Serum was separated and immediately tested for hemolysis index (HI), potassium, aspartate aminotransferase (AST), and lactate dehydrogenase (LDH). The HI always remained below the limit of detection of the method (< 0.5 g/L) in all tubes. No statistically significant differences were recorded in any parameter except potassium, which increased by 0.10 mmol/L in 4 mL full-draw tubes. No clinically significant variation was however recorded in any tube. The results suggest that all types of tubes tested might be used interchangeably in term of risk of spurious hemolysis.
Measurement of Afterburning Effect of Underoxidized Explosives by Underwater Explosion Method
NASA Astrophysics Data System (ADS)
Cao, Wei; He, Zhongqi; Chen, Wanghua
2015-04-01
The afterburning effect of TNT and a desensitized hexogen RDX-Al explosive was studied in a defined gas volume under water. A double-layer container (DLC) filled with different gases (air, oxygen, and nitrogen) was used to control and distinguish the afterburning effect of explosives. After the charges in the DLC were initiated under water, the shock wave signals were collected and analyzed. It is shown that shock wave peak pressures are duly in compliance with explosion similarity law, pressure, and impulse histories for explosions in oxygen and air are greater than those recorded for explosions in nitrogen due to the afterburing reaction. Moreover, the afterburning energy was calculated. Results show that even though there is excess oxygen in the gas volume, the afterburning energy may not reach the theoretically maximum value. This result is different from that in confined explosion, where the presence of excess oxygen in the compressed gas filling a bomb leads to complete combustion of the detonation products.
Biocytin-labelling and its impact on late 20th century studies of cortical circuitry
Thomson, Alex M.; Armstrong, William E.
2010-01-01
In recognition of the impact that a powerful new anatomical tool, such as the Golgi method, can have, this essay highlights the enormous influence that biocytin-filling has had on modern neuroscience. This method has allowed neurones that have been recorded intracellularly, ‘whole-cel’ or juxta-cellularly, to be identified anatomically, forming a vital link between functional and structural studies. It has been applied throughout the nervous system and has become a fundamental component of our technical armoury. A comprehensive survey of the applications to which the biocytin-filling approach has been put, would fill a large volume. This essay therefore focuses on one area, neocortical microcircuitry and the ways in which combining physiology and anatomy have revealed rules that help us the explain its previously indecipherable variability and complexity. PMID:20399808
Left atrial strain: a new parameter for assessment of left ventricular filling pressure.
Cameli, Matteo; Mandoli, Giulia Elena; Loiacono, Ferdinando; Dini, Frank Lloyd; Henein, Michael; Mondillo, Sergio
2016-01-01
In order to obtain accurate diagnosis, treatment and prognostication in many cardiac conditions, there is a need for assessment of left ventricular (LV) filling pressure. While systole depends on ejection function of LV, diastole and its disturbances influence filling function and pressures. The commonest condition that represents the latter is heart failure with preserved ejection fraction in which LV ejection is maintained, but diastole is disturbed and hence filling pressures are raised. Significant diastolic dysfunction results in raised LV end-diastolic pressure, mean left atrial (LA) pressure and pulmonary capillary wedge pressure, all referred to as LV filling pressures. Left and right heart catheterization has traditionally been used as the gold standard investigation for assessing these pressures. More recently, Doppler echocardiography has taken over such application because of its noninvasive nature and for being patient friendly. A number of indices are used to achieve accurate assessment of filling pressures including: LV pulsed-wave filling velocities (E/A ratio, E wave deceleration time), pulmonary venous flow (S wave and D wave), tissue Doppler imaging (E' wave and E/E' ratio) and LA volume index. LA longitudinal strain derived from speckle tracking echocardiography (STE) is also sensitive in estimating intracavitary pressures. It is angle-independent, thus overcomes Doppler limitations and provides highly reproducible measures of LA deformation. This review examines the application of various Doppler echocardiographic techniques in assessing LV filling pressures, in particular the emerging role of STE in assessing LA pressures in various conditions, e.g., HF, arterial hypertension and atrial fibrillation.
NASA Technical Reports Server (NTRS)
Araki, Suguru
1991-01-01
The kinetic theory of planetary rings developed by Araki and Tremaine (1986) and Araki (1988) is extended and refined, with a focus on the implications of finite particle size: (1) nonlocal collisions and (2) finite filling factors. Consideration is given to the derivation of the equations for the local steady state, the low-optical-depth limit, and the steady state at finite filling factors (including the effects of collision inelasticity, spin degrees of freedom, and self-gravity). Numerical results are presented in extensive graphs and characterized in detail. The importance of distinguishing effects (1) and (2) at low optical depths is stressed, and the existence of vertical density profiles with layered structures at high filling factors is demonstrated.
NASA Astrophysics Data System (ADS)
Wang, Lei; Li, Yanzhong; Zhang, Feini; Ma, Yuan
2015-12-01
Two finite difference computer models, aiming at the process predictions of no-vent fill in normal gravity and microgravity environments respectively, are developed to investigate the filling performance in a liquid hydrogen (LH2) tank. In the normal gravity case model, the tank/fluid system is divided into five control volume including ullage, bulk liquid, gas-liquid interface, ullage-adjacent wall, and liquid-adjacent wall. In the microgravity case model, vapor-liquid thermal equilibrium state is maintained throughout the process, and only two nodes representing fluid and wall regions are applied. To capture the liquid-wall heat transfer accurately, a series of heat transfer mechanisms are considered and modeled successively, including film boiling, transition boiling, nucleate boiling and liquid natural convection. The two models are validated by comparing their prediction with experimental data, which shows good agreement. Then the two models are used to investigate the performance of no-vent fill in different conditions and several conclusions are obtained. It shows that in the normal gravity environment the no-vent fill experiences a continuous pressure rise during the whole process and the maximum pressure occurs at the end of the operation, while the maximum pressure of the microgravity case occurs at the beginning stage of the process. Moreover, it seems that increasing inlet mass flux has an apparent influence on the pressure evolution of no-vent fill process in normal gravity but a little influence in microgravity. The larger initial wall temperature brings about more significant liquid evaporation during the filling operation, and then causes higher pressure evolution, no matter the filling process occurs under normal gravity or microgravity conditions. Reducing inlet liquid temperature can improve the filling performance in normal gravity, but cannot significantly reduce the maximum pressure in microgravity. The presented work benefits the understanding of the no-vent fill performance and may guide the design of on-orbit no-vent fill system.
Utilization of tooth filling services by people with disabilities in Taiwan.
Chen, Ming-Chuan; Kung, Pei-Tseng; Su, Hsun-Pi; Yen, Suh-May; Chiu, Li-Ting; Tsai, Wen-Chen
2016-04-05
The oral condition of people with disabilities has considerable influence on their physical and mental health. However, nationwide surveys regarding this group have not been conducted. For this study, we used the National Health Insurance Research Database to explore the tooth filling utilization among people with disabilities. Using the database of the Ministry of the Interior in 2008 which included people with disabilities registered, we merged with the medical claims database in 2008 of the Bureau of National Health Insurance to calculate the tooth filling utilization and to analyze relative factors. We recruited 993,487 people with disabilities as the research sample. The tooth filling utilization was 17.53 %. The multiple logistic regression result showed that the utilization rate of men was lower than that of women (OR = 0.78, 95 % CI = 0.77-0.79) and older people had lower utilization rates (aged over 75, OR = 0.22, 95 % CI = 0.22-0.23) compared to those under the age of 20. Other factors that significantly influenced the low tooth filling utilization included a low education level, living in less urbanized areas, low economic capacity, dementia, and severe disability. We identified the factors that influence and decrease the tooth-filling service utilization rate: male sex, old age, low education level, being married, indigenous ethnicity, residing in a low urbanization area, low income, chronic circulatory system diseases, dementia, and severe disabilities. We suggest establishing proper medical care environments for high-risk groups to maintain their quality of life.
Ainslie, Philip N.; Hughes, Michael G.; Stöhr, Eric J.; Cotter, James D.; Tymko, Michael M.; Day, Trevor A.; Bakker, Akke; Shave, Rob
2015-01-01
Impaired myocardial systolic contraction and diastolic relaxation have been suggested as possible mechanisms contributing to the decreased stroke volume (SV) observed at high altitude (HA). To determine whether intrinsic myocardial performance is a limiting factor in the generation of SV at HA, we assessed left ventricular (LV) systolic and diastolic mechanics and volumes in 10 healthy participants (aged 32 ± 7; mean ± SD) at rest and during exercise at sea level (SL; 344 m) and after 10 days at 5,050 m. In contrast to SL, LV end-diastolic volume was ∼19% lower at rest (P = 0.004) and did not increase during exercise despite a greater untwisting velocity. Furthermore, resting SV was lower at HA (∼17%; 60 ± 10 vs. 70 ± 8 ml) despite higher LV twist (43%), apical rotation (115%), and circumferential strain (17%). With exercise at HA, the increase in SV was limited (12 vs. 22 ml at SL), and LV apical rotation failed to augment. For the first time, we have demonstrated that EDV does not increase upon exercise at high altitude despite enhanced in vivo diastolic relaxation. The increase in LV mechanics at rest may represent a mechanism by which SV is defended in the presence of a reduced EDV. However, likely because of the higher LV mechanics at rest, no further increase was observed up to 50% peak power. Consequently, although hypoxia does not suppress systolic function per se, the capacity to increase SV through greater deformation during submaximal exercise at HA is restricted. PMID:25749445
Radio mode feedback: Does relativity matter?
NASA Astrophysics Data System (ADS)
Perucho, Manel; Martí, José-María; Quilis, Vicent; Borja-Lloret, Marina
2017-10-01
Radio mode feedback, associated with the propagation of powerful outflows in active galaxies, is a crucial ingredient in galaxy evolution. Extragalactic jets are well collimated and relativistic, both in terms of thermodynamics and kinematics. They generate strong shocks in the ambient medium, associated with observed hotspots, and carve cavities that are filled with the shocked jet flow. In this Letter, we compare the pressure evolution in the hotspot and the cavity generated by relativistic and classical jets. Our results show that the classical approach underestimates the cavity pressure by a factor ≥2 for a given shocked volume during the whole active phase. The tension between both approaches can only be alleviated by unrealistic jet flow densities or gigantic jet areas in the classical case. As a consequence, the efficiency of a relativistic jet heating the ambient is typically ∼20 per cent larger compared with a classical jet, and the heated volume is 2 to 10 times larger during the time evolution. This conflict translates into two substantially disparate manners, both spatially and temporal, of heating the ambient medium. These differences are expected to have relevant implications on the star formation rates of the host galaxies and their evolution.
Wave energy devices with compressible volumes.
Kurniawan, Adi; Greaves, Deborah; Chaplin, John
2014-12-08
We present an analysis of wave energy devices with air-filled compressible submerged volumes, where variability of volume is achieved by means of a horizontal surface free to move up and down relative to the body. An analysis of bodies without power take-off (PTO) systems is first presented to demonstrate the positive effects a compressible volume could have on the body response. Subsequently, two compressible device variations are analysed. In the first variation, the compressible volume is connected to a fixed volume via an air turbine for PTO. In the second variation, a water column separates the compressible volume from another volume, which is fitted with an air turbine open to the atmosphere. Both floating and bottom-fixed, axisymmetric, configurations are considered, and linear analysis is employed throughout. Advantages and disadvantages of each device are examined in detail. Some configurations with displaced volumes less than 2000 m 3 and with constant turbine coefficients are shown to be capable of achieving 80% of the theoretical maximum absorbed power over a wave period range of about 4 s.
Wave energy devices with compressible volumes
Kurniawan, Adi; Greaves, Deborah; Chaplin, John
2014-01-01
We present an analysis of wave energy devices with air-filled compressible submerged volumes, where variability of volume is achieved by means of a horizontal surface free to move up and down relative to the body. An analysis of bodies without power take-off (PTO) systems is first presented to demonstrate the positive effects a compressible volume could have on the body response. Subsequently, two compressible device variations are analysed. In the first variation, the compressible volume is connected to a fixed volume via an air turbine for PTO. In the second variation, a water column separates the compressible volume from another volume, which is fitted with an air turbine open to the atmosphere. Both floating and bottom-fixed, axisymmetric, configurations are considered, and linear analysis is employed throughout. Advantages and disadvantages of each device are examined in detail. Some configurations with displaced volumes less than 2000 m3 and with constant turbine coefficients are shown to be capable of achieving 80% of the theoretical maximum absorbed power over a wave period range of about 4 s. PMID:25484609
Paterson, Janis E; Gao, Wanzhen; Sundborn, Gerhard; Cartwright, Susan
2011-02-01
To examine maternal and socio-demographic factors associated with oral health practices and experiences in six-year-old Pacific children. The longitudinal Pacific Islands Families (PIF) study is following a cohort of Pacific children born in Auckland, New Zealand in 2000. At approximately six years postpartum maternal reports (n = 1001) on child oral health practices and experiences of fillings and extractions were gathered. Forty-five per cent of mothers reported that their child had experienced fillings or extractions. After adjusting for confounding factors, we found that Tongan children were almost twice as likely to have their teeth filled or extracted than Samoan children (OR, 1.93; 95%, 1.34-2.77). Differences between Samoan children and children of other ethnic groups were not significant. Children of mothers who had secondary qualifications were significantly less likely to have their teeth filled or extracted compared to children of mothers who had postsecondary qualifications (OR, 0.634; 95%, 0.44-0.90). Prolonged duration of breastfeeding was associated with an increased likelihood of filling or extraction experience. In terms of maternal oral hygiene, maternal tooth brushing frequency of less that once a day was significantly associated with increased odds of fillings and/or extractions in their children (OR, 1.35; 95% CI, 1.02-1.79). Children who were sometimes supervised for tooth brushing were significantly more likely to have fillings or extractions than children who were not provided supervision. These findings highlight the role of cultural factors and maternal hygiene in child oral health outcomes and suggest that health promotion efforts should encompass the whole family and embrace a culturally appropriate approach. © 2010 John Wiley & Sons A/S.
Decrease in coronary vascular volume in systole augments cardiac contraction.
Willemsen, M J; Duncker, D J; Krams, R; Dijkman, M A; Lamberts, R R; Sipkema, P; Westerhof, N
2001-08-01
Coronary arterial inflow is impeded and venous outflow is increased as a result of the decrease in coronary vascular volume due to cardiac contraction. We evaluated whether cardiac contraction is influenced by interfering with the changes of the coronary vascular volume over the heart cycle. Length-tension relationships were determined in Tyrode-perfused rat papillary muscle and when coronary vascular volume changes were partly inhibited by filling it with congealed gelatin or perfusing it with a high viscosity dextran buffer. Also, myocyte thickening during contraction was reduced by placing a silicon tube around the muscle. Increasing perfusion pressure from 8 to 80 cmH2O, increased developed tension by approximately 40%. When compared with the low perfusion state, developed tension of the gelatin-filled vasculature was reduced to 43 +/- 6% at the muscle length where the muscle generates the largest developed tension (n = 5, means +/- SE). Dextran reduced developed tension to 73 +/- 6% (n = 6). The silicon tube, in low perfusion state, reduced the developed tension to 83 +/- 7% (n = 4) of control. Time-control and oxygen-lowering experiments show that the findings are based on mechanical effects. Thus interventions to prevent myocyte thickening reduce developed tension. We hypothesize that when myocyte thickening is prevented, intracellular pressure increases and counteracts the force produced by the contractile apparatus. We conclude that emptying of the coronary vasculature serves a physiological purpose by facilitating cardiomyocyte thickening thereby augmenting force development.
Quantification of the cerebrospinal fluid from a new whole body MRI sequence
NASA Astrophysics Data System (ADS)
Lebret, Alain; Petit, Eric; Durning, Bruno; Hodel, Jérôme; Rahmouni, Alain; Decq, Philippe
2012-03-01
Our work aims to develop a biomechanical model of hydrocephalus both intended to perform clinical research and to assist the neurosurgeon in diagnosis decisions. Recently, we have defined a new MR imaging sequence based on SPACE (Sampling Perfection with Application optimized Contrast using different flip-angle Evolution). On these images, the cerebrospinal fluid (CSF) appears as a homogeneous hypersignal. Therefore such images are suitable for segmentation and for volume assessment of the CSF. In this paper we present a fully automatic 3D segmentation of such SPACE MRI sequences. We choose a topological approach considering that CSF can be modeled as a simply connected object (i.e. a filled sphere). First an initial object which must be strictly included in the CSF and homotopic to a filled sphere, is determined by using a moment-preserving thresholding. Then a priority function based on an Euclidean distance map is computed in order to control the thickening process that adds "simple points" to the initial thresholded object. A point is called simple if its addition or its suppression does not result in change of topology neither for the object, nor for the background. The method is validated by measuring fluid volume of brain phantoms and by comparing our volume assessments on clinical data to those derived from a segmentation controlled by expert physicians. Then we show that a distinction between pathological cases and healthy adult people can be achieved by a linear discriminant analysis on volumes of the ventricular and intracranial subarachnoid spaces.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ke, Weijun; Xiao, Chuanxiao; Wang, Changlei
2016-05-04
Lead thiocyanate in the perovskite precursor can increase the grain size of a perovskite thin film and reduce the conductivity of the grain boundaries, leading to perovskite solar cells with reduced hysteresis and enhanced fill factor. A planar perovskite solar cell with grain boundary and interface passivation achieves a steady-state efficiency of 18.42%.
A pilot study on bladder wall thickness at different filling stages
NASA Astrophysics Data System (ADS)
Zhang, Xi; Liu, Yang; Li, Baojuan; Zhang, Guopeng; Liang, Zhengrong; Lu, Hongbing
2015-03-01
The ever-growing death rate and the high recurrence of bladder cancer make the early detection and appropriate followup procedure of bladder cancer attract more attention. Compare to optical cystoscopy, image-based studies have revealed its potentials in non-invasive observations of the abnormities of bladder recently, in which MR imaging turns out to be a better choice for bladder evaluation due to its non-ionizing and high contrast between urine and wall tissue. Recent studies indicate that bladder wall thickness tends to be a good indicator for detecting bladder wall abnormalities. However, it is difficult to quantitatively compare wall thickness of the same subject at different filling stages or among different subjects. In order to explore thickness variations at different bladder filling stages, in this study, we preliminarily investigate the relationship between bladder wall thickness and bladder volume based on a MRI database composed of 40 datasets acquired from 10 subjects at different filling stages, using a pipeline for thickness measurement and analysis proposed in our previous work. The Student's t-test indicated that there was no significant different on wall thickness between the male group and the female group. The Pearson correlation analysis result indicated that negative correlation with a correlation coefficient of -0.8517 existed between the wall thickness and bladder volume, and the correlation was significant(p <0.01). The corresponding linear regression equation was then estimated by the unary linear regression. Compared to the absolute value of wall thickness, the z-score of wall thickness would be more appropriate to reflect the thickness variations. For possible abnormality detection of a bladder based on wall thickness, the intra-subject and inter-subject thickness variation should be considered.
Marui, Akira; Nishina, Takeshi; Saji, Yoshiaki; Yamazaki, Kazuhiro; Shimamoto, Takeshi; Ikeda, Tadashi; Sakata, Ryuzo
2010-05-01
Surgical ventricular restoration (SVR) has been introduced to restore the dilated left ventricular (LV) chamber and improve LV systolic function; however, SVR has also been reported to detrimentally affect LV diastolic properties. We sought to investigate the impact of preoperative LV diastolic function on outcomes after SVR in patients with heart failure. Sixty-seven patients (60 +/- 14 years) with LV systolic dysfunction (LV ejection fraction, 0.27 +/- 0.10) underwent SVR. They were evaluated by echocardiography preoperatively, and early (
DOT National Transportation Integrated Search
1984-03-01
During construction of Interstate I-10 between Baton Rouge and LaPlace, Louisiana, highly organic swamp deposits were excavated and replaced with hydraulically pumped river sand. Recently, excessive settlement was encountered at numerous cross-drain ...
49 CFR 193.2513 - Transfer procedures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Practice.” (2) Before transfer, verify that each receiving container or tank vehicle does not contain any... volume of each receiving container or tank vehicle to ensure that expansion of the incoming fluid due to... partially filled (excluding cooldown heel) container, determine any differences in temperature or specific...
49 CFR 193.2513 - Transfer procedures.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Practice.” (2) Before transfer, verify that each receiving container or tank vehicle does not contain any... volume of each receiving container or tank vehicle to ensure that expansion of the incoming fluid due to... partially filled (excluding cooldown heel) container, determine any differences in temperature or specific...
49 CFR 193.2513 - Transfer procedures.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Practice.” (2) Before transfer, verify that each receiving container or tank vehicle does not contain any... volume of each receiving container or tank vehicle to ensure that expansion of the incoming fluid due to... partially filled (excluding cooldown heel) container, determine any differences in temperature or specific...
49 CFR 193.2513 - Transfer procedures.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Practice.” (2) Before transfer, verify that each receiving container or tank vehicle does not contain any... volume of each receiving container or tank vehicle to ensure that expansion of the incoming fluid due to... partially filled (excluding cooldown heel) container, determine any differences in temperature or specific...
Diversity Digest. Volume 8, Number 2
ERIC Educational Resources Information Center
Giles, Mark, Ed.
2004-01-01
This issue of "Diversity Digest" contains articles and resources focused on the lasting lessons, legacies, and spirit of the 1954 "Brown v. Board of Education" decision. This year of the fiftieth anniversary, filled with ceremonies, celebrations, and commemorations of that decision has highlighted many well known and lesser…
Nagaveni, N B; Yadav, Sneha; Poornima, P; Reddy, Vv Subba; Roshan, N M
Various obturation techniques have been evaluated for better filling of the root canals in primary teeth using different methods. Spiral Computed Tomography (SCT) is a new revolution in the pediatric endodontics for assessment of quality of the obturation from 3 dimensions. To evaluate the efficiency of 5 different obturation methods in delivering the filling material into the canals of primary teeth using Spiral Computed Tomography scan. A total of 50 canals of primary teeth were prepared, divided into 5 groups with 10 canals in each group and obturated with Zinc Oxide Eugenol cement using 5 different obturation techniques such as Local anesthetic syringe, Tuberculin syringe, Endodontic plugger, hand held Lentulo-spiral, and Lentulo-spiral mounted on slow speed hand piece. The pre and post obturation volume and finally the Percentage of Obturated Volume (POV) were calculated using SCT scan for each group. The data obtained was statistically analyzed using One-way Analysis of Variance (ANOVA) and Tukey's post-hoc test. Lentulo-spiral hand held showed highest POV value followed by Lentulospiral mounted to hand piece, Tuberculin syringe and Endodontic plugger; whereas Anesthetic syringe had least POV (P < 0.05). Lentulo-spiral hand held is the best obturating technique among the 5 groups evaluated as the canals of this group showed maximum percentage of filled material. However, a further study with large sample size is highly essential.
CO2-filled vesicles in mid-ocean basalt
Moore, J.G.; Batchelder, J.N.; Cunningham, C.G.
1977-01-01
Volatile-filled vesicles are present in minor amounts in all samples of mid-ocean basalt yet collected (and presumably erupted) down to depths of 4.8 km. When such vesicles are pierced in liquid under standard conditions, the volume expansion of the gas is 0.2 ?? 0.05 times the eruption pressure in bars or 20 ?? 5 times the eruption depth in km. Such expansion could be used as a measure of eruption depth. A variety of techniques: (1) vacuum crushing and gas chromatographic, freezing separation, and mass spectrographic analyses; (2) measurements of phase changes on a freezing microscope stage; (3) microscopic chemical and solubility observations; and (4) volume change measurements, all indicate that CO2 comprises more than 95% by volume of the vesicle gas in several submarine basalt samples from the Atlantic and Pacific. The CO2 held in vesicles is present in quantities about equal to or greater than that presumed to be dissolved in the glass (melt) and amounts to 400-900 ppm of the rock. The rigid temperature of the glass is 800-1000??C and increases for shallower samples. A sulfur gas was originally present in subordinate amounts in the vesicles, but has largely reacted with iron in the vesicle walls to produce sulfide spherules. ?? 1977.
An improved bathymetric model for the modern and palaeo Lake Eyre
NASA Astrophysics Data System (ADS)
Leon, J. X.; Cohen, T. J.
2012-11-01
Here we demonstrate the applicability of using altimetry data and Landsat imagery to provide the most accurate digital elevation model (DEM) of Australia's largest playa lake — Lake Eyre. We demonstrate through the use of geospatial techniques a robust assessment of lake area and volume of recent lake-filling episodes whilst also providing the most accurate estimates of area and volume for larger lake filling episodes that occurred throughout the last glacial cycle. We highlight that at a depth of 25 m Lake Mega-Eyre would merge with the adjacent Lake Mega-Frome to form an immense waterbody with a combined area of almost 35,000 km2 and a combined volume of ~ 520 km3. This would represent a vast water body in what is now the arid interior of the Australian continent. The improved DEM is more reliable from a geomorphological and hydrological perspective and allows a more accurate assessment of water balance under the modern hydrological regime. The results presented using GLAS/ICESat data suggest that earlier historical soundings were correct and the actual lowest topographic point in Australia is - 15.6 m below sea level. The results also contrast nicely the different basin characteristics of two adjacent lake systems: Lake Eyre and Lake Frome.
Kwiatek, Monika A; Menne, Dieter; Steingoetter, Andreas; Goetze, Oliver; Forras-Kaufman, Zsofia; Kaufman, Elad; Fruehauf, Heiko; Boesiger, Peter; Fried, Michael; Schwizer, Werner; Fox, Mark R
2009-11-01
This study assessed the effects of meal volume (MV) and calorie load (CL) on gastric function. MRI and a minimally invasive fiber-optic recording system (FORS) provided simultaneous measurement of gastric volume and pressure changes during gastric filling and emptying of a liquid nutrient meal in physiological conditions. The gastric response to 12 iso-osmolar MV-CL combinations of a multinutrient drink (MV: 200, 400, 600, 800 ml; CL: 200, 300, 400 kcal) was tested in 16 healthy subjects according to a factorial design. Total gastric volume (TGV) and gastric content volume (GCV = MV + secretion) were measured by MRI during nasogastric meal infusion and gastric emptying over 60 min. Intragastric pressure was assessed at 1 Hz by FORS. The dynamic change in postprandial gastric volumes was described by a validated three-component linear exponential model. The stomach expanded with MV, but the ratio of GCV:MV at t(0) diminished with increasing MV (P < 0.01). Postprandial changes in TGV followed those of GCV. Intragastric pressure increased with MV, and this effect was augmented further by CL (P = 0.02); however, the absolute pressure rise was <4 mmHg. A further postprandial increase of gastric volumes was observed early on before any subsequent volume decrease. This "early" increase in GCV was greater for smaller than larger MV (P < 0.01), indicating faster initial gastric emptying of larger MV. In contrast, volume change during filling and in the early postprandial period were unaffected by CL. In the later postprandial period, gastric emptying rate continued to be more rapid with high MVs (P < 0.001); however, at any given volume, gastric emptying was slowed by higher CL (P < 0.001). GCV half-emptying time decreased with CL at 18 +/- 6 min for each additional 100-kcal load (P < 0.001). These findings indicate that gastric wall stress (passive strain and active tone) provides the driving force for gastric emptying, but distal resistance to gastric outflow regulates further passage of nutrients. The distinct early phase of gastric emptying with relatively rapid, uncontrolled passage of nutrients into the small bowel, modulated by meal volume but not nutrient composition, ensures that the delivery of nutrients in the later postprandial period is related to the overall calorie load of the meal.
Boda-Heggemann, Judit; Haneder, Stefan; Ehmann, Michael; Sihono, Dwi Seno Kuncoro; Wertz, Hansjörg; Mai, Sabine; Kegel, Stefan; Heitmann, Sigrun; von Swietochowski, Sandra; Lohr, Frank; Wenz, Frederik
2015-01-01
Target-volume definition for prostate cancer in patients with bilateral metal total hip replacements (THRs) is a challenge because of metal artifacts in the planning computed tomography (CT) scans. Magnetic resonance imaging (MRI) can be used for matching and prostate delineation; however, at a spatial and temporal distance from the planning CT, identical rectal and vesical filling is difficult to achieve. In addition, MRI may also be impaired by metal artifacts, even resulting in spatial image distortion. Here, we present a method to define prostate target volumes based on ultrasound images acquired during CT simulation and online-matched to the CT data set directly at the planning CT. A 78-year-old patient with cT2cNxM0 prostate cancer with bilateral metal THRs was referred to external beam radiation therapy. T2-weighted MRI was performed on the day of the planning CT with preparation according to a protocol for reproducible bladder and rectal filling. The planning CT was obtained with the immediate acquisition of a 3-dimensional ultrasound data set with a dedicated stereotactic ultrasound system for online intermodality image matching referenced to the isocenter by ceiling-mounted infrared cameras. MRI (offline) and ultrasound images (online) were thus both matched to the CT images for planning. Daily image guided radiation therapy (IGRT) was performed with transabdominal ultrasound and compared with cone beam CT. Because of variations in bladder and rectal filling and metal-induced image distortion in MRI, soft-tissue-based matching of the MRI to CT was not sufficient for unequivocal prostate target definition. Ultrasound-based images could be matched, and prostate, seminal vesicles, and target volumes were reliably defined. Daily IGRT could be successfully completed with transabdominal ultrasound with good accordance between cone beam CT and ultrasound. For prostate cancer patients with bilateral THRs causing artifacts in planning CTs, ultrasound referenced to the isocenter of the CT simulator and acquired with intermodal online coregistration directly at the planning CT is a fast and easy method to reliably delineate the prostate and target volumes and for daily IGRT. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
High-resolution observations of the polar magnetic fields of the sun
NASA Technical Reports Server (NTRS)
Lin, H.; Varsik, J.; Zirin, H.
1994-01-01
High-resolution magnetograms of the solar polar region were used for the study of the polar magnetic field. In contrast to low-resolution magnetograph observations which measure the polar magnetic field averaged over a large area, we focused our efforts on the properties of the small magnetic elements in the polar region. Evolution of the filling factor (the ratio of the area occupied by the magnetic elements to the total area) of these magnetic elements, as well as the average magnetic field strength, were studied during the maximum and declining phase of solar cycle 22, from early 1991 to mid-1993. We found that during the sunspot maximum period, the polar regions were occupied by about equal numbers of positive and negative magnetic elements, with equal average field strength. As the solar cycle progresses toward sunspot minimum, the magnetic field elements in the polar region become predominantly of one polarity. The average magnetic field of the dominant polarity elements also increases with the filling factor. In the meanwhile, both the filling factor and the average field strength of the non-dominant polarity elements decrease. The combined effects of the changing filling factors and average field strength produce the observed evolution of the integrated polar flux over the solar cycle. We compared the evolutionary histories of both filling factor and average field strength, for regions of high (70-80 deg) and low (60-70 deg) latitudes. For the south pole, we found no significant evidence of difference in the time of reversal. However, the low-latitude region of the north pole did reverse polarity much earlier than the high-latitude region. It later showed an oscillatory behavior. We suggest this may be caused by the poleward migration of flux from a large active region in 1989 with highly imbalanced flux.
Minnesota retrofit insulation in situ test program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1978-06-01
The use of cellulose, glass fiber, rock/slag fiber and urea formaldehyde installed as retrofit insulation materials in residential walls and ceilings was studied. Homes were selected for testing according to the type of retrofit insulation, age of retrofit insulation and whether the retrofit was in the wall or ceiling. The total project was comprised of 22 wall and 48 ceiling samples. Samples of retrofit insulation were taken from an area of three to four square feet in the ceiling or wall of the home. The sample volume was measured, the sample removed and double-sealed in polyethylene bags. The samples weremore » shipped to the laboratory for testing. Laboratory measurements were made of density, moisture content, thermal resistance, and relative flammability of each sample. Additionally, the friability and compressive strength of each urea-formaldehyde foam sample was measured. The following results were obtained. Cellulosic loose fill insulation tests indicated that settling and moisture build-up are not serious problems. Flammability is a concern. Age did not affect the properties of the cellulosic loose fill, but fungal growth was evident. Shrinkage, ranging from 2.5 to 9 percent, averaging 4.5 percent, was exhibited. Degradation of the foam samples with time did not occur. Density was the most critical property affecting the other properties. The higher the density, the higher the thermal resistence per inch, the lower the friability and the higher the compressive strength. The accurate prediction of the fiber diameter, amount of unfiberized mineral, and extent of modular clumping thermal resistance of loose fill mineral fiber insulations is related to and is not solely a factor of density. The materials in this sample did not noticeably affect the structure or wiring of the retrofitted homes. (LCL)« less
Spheroidal and conical shapes of ferrofluid-filled capsules in magnetic fields
NASA Astrophysics Data System (ADS)
Wischnewski, Christian; Kierfeld, Jan
2018-04-01
We investigate the deformation of soft spherical elastic capsules filled with a ferrofluid in external uniform magnetic fields at fixed volume by a combination of numerical and analytical approaches. We develop a numerical iterative solution strategy based on nonlinear elastic shape equations to calculate the stretched capsule shape numerically and a coupled finite element and boundary element method to solve the corresponding magnetostatic problem and employ analytical linear response theory, approximative energy minimization, and slender-body theory. The observed deformation behavior is qualitatively similar to the deformation of ferrofluid droplets in uniform magnetic fields. Homogeneous magnetic fields elongate the capsule and a discontinuous shape transition from a spheroidal shape to a conical shape takes place at a critical field strength. We investigate how capsule elasticity modifies this hysteretic shape transition. We show that conical capsule shapes are possible but involve diverging stretch factors at the tips, which gives rise to rupture for real capsule materials. In a slender-body approximation we find that the critical susceptibility above which conical shapes occur for ferrofluid capsules is the same as for droplets. At small fields capsules remain spheroidal and we characterize the deformation of spheroidal capsules both analytically and numerically. Finally, we determine whether wrinkling of a spheroidal capsule occurs during elongation in a magnetic field and how it modifies the stretching behavior. We find the nontrivial dependence between the extent of the wrinkled region and capsule elongation. Our results can be helpful in quantitatively determining capsule or ferrofluid material properties from magnetic deformation experiments. All results also apply to elastic capsules filled with a dielectric liquid in an external uniform electric field.
Stability of selected volatile breath constituents in Tedlar, Kynar and Flexfilm sampling bags
Mochalski, Paweł; King, Julian; Unterkofler, Karl; Amann, Anton
2016-01-01
The stability of 41 selected breath constituents in three types of polymer sampling bags, Tedlar, Kynar, and Flexfilm, was investigated using solid phase microextraction and gas chromatography mass spectrometry. The tested molecular species belong to different chemical classes (hydrocarbons, ketones, aldehydes, aromatics, sulphurs, esters, terpenes, etc.) and exhibit close-to-breath low ppb levels (3–12 ppb) with the exception of isoprene, acetone and acetonitrile (106 ppb, 760 ppb, 42 ppb respectively). Stability tests comprised the background emission of contaminants, recovery from dry samples, recovery from humid samples (RH 80% at 37 °C), influence of the bag’s filling degree, and reusability. Findings yield evidence of the superiority of Tedlar bags over remaining polymers in terms of background emission, species stability (up to 7 days for dry samples), and reusability. Recoveries of species under study suffered from the presence of high amounts of water (losses up to 10%). However, only heavier volatiles, with molecular masses higher than 90, exhibited more pronounced losses (20–40%). The sample size (the degree of bag filling) was found to be one of the most important factors affecting the sample integrity. To sum up, it is recommended to store breath samples in pre-conditioned Tedlar bags up to 6 hours at the maximum possible filling volume. Among the remaining films, Kynar can be considered as an alternative to Tedlar; however, higher losses of compounds should be expected even within the first hours of storage. Due to the high background emission Flexfilm is not suitable for sampling and storage of samples for analyses aiming at volatiles at a low ppb level. PMID:23323261
Effects of selective attention on perceptual filling-in.
De Weerd, P; Smith, E; Greenberg, P
2006-03-01
After few seconds, a figure steadily presented in peripheral vision becomes perceptually filled-in by its background, as if it "disappeared". We report that directing attention to the color, shape, or location of a figure increased the probability of perceiving filling-in compared to unattended figures, without modifying the time required for filling-in. This effect could be augmented by boosting attention. Furthermore, the frequency distribution of filling-in response times for attended figures could be predicted by multiplying the frequencies of response times for unattended figures with a constant. We propose that, after failure of figure-ground segregation, the neural interpolation processes that produce perceptual filling-in are enhanced in attended figure regions. As filling-in processes are involved in surface perception, the present study demonstrates that even very early visual processes are subject to modulation by cognitive factors.
High altitude current-voltage measurement of GaAs/Ge solar cells
NASA Astrophysics Data System (ADS)
Hart, Russell E., Jr.; Brinker, David J.; Emery, Keith A.
Measurements of high-voltage (Voc of 1.2 V) gallium arsenide on germanium tandem junction solar cells at air mass 0.22 showed that the insolation in the red portion of the solar spectrum is insufficient to obtain high fill factor. On the basis of measurements in the LeRC X-25L solar simulator, these cells were believed to be as efficient as 21.68 percent AM0. Solar simulator spectrum errors in the red end allowed the fill factor to be as high as 78.7 percent. When a similar cell's current-voltage characteristic was measured at high altitude in the NASA Lear Jet Facility, a loss of 15 percentage points in fill factor was observed. This decrease was caused by insufficient current in the germanium bottom cell of the tandem stack.
Thiros, Susan A.; Bexfield, Laura M.; Anning, David W.; Huntington, Jena M.
2010-01-01
The National Water-Quality Assessment (NAWQA) Program of the U.S. Geological Survey has been conducting a regional analysis of water quality in the principal aquifer systems in the southwestern United States (hereinafter, “Southwest”) since 2005. Part of the NAWQA Program, the objective of the Southwest Principal Aquifers (SWPA) study is to develop a better understanding of water quality in basin-fill aquifers in the region by synthesizing information from case studies of 15 basins into a common set of important natural and human-related factors found to affect groundwater quality.The synthesis consists of three major components:1. Summary of current knowledge about the groundwater systems, and the status of, changes in, and influential factors affecting quality of groundwater in basin-fill aquifers in 15 basins previously studied by NAWQA (this report).2. Development of a conceptual model of the primary natural and human-related factors commonly affecting groundwater quality, thereby building a regional understanding of the susceptibility and vulnerability of basin-fill aquifers to contaminants.3. Development of statistical models that relate the concentration or occurrence of specific chemical constituents in groundwater to natural and human-related factors linked to the susceptibility and vulnerability of basin-fill aquifers to contamination.Basin-fill aquifers occur in about 200,000 mi2 of the 410,000 mi2 SWPA study area and are the primary source of groundwater supply for cities and agricultural communities. Four of the principal aquifers or aquifer systems of the United States are included in the basin-fill aquifers of the study area: (1) the Basin and Range basin-fill aquifers in California, Nevada, Utah, and Arizona; (2) the Rio Grande aquifer system in New Mexico and Colorado; (3) the California Coastal Basin aquifers; and (4) the Central Valley aquifer system in California. Because of the generally limited availability of surface-water supplies in the arid to semiarid climate, cultural and economic activities in the Southwest are particularly dependent on supplies of good-quality groundwater. Irrigation and public-supply withdrawals from basin-fill aquifers in the study area account for about one quarter of the total withdrawals from all aquifers in the United States.Many factors influence the quality of groundwater in the 15 case-study basins, but some common factors emerge from the basin summaries presented in this report. These factors include the chemical composition of the recharge water, consolidated rock geology and composition of aquifer materials derived from consolidated rock, and land and water use. The major water-quality issues in many of the developed case-study basins are increased concentrations of dissolved solids, nitrate, and VOCs in groundwater as a result of human activities.The information presented and the citations listed in this report serve as a resource for those interested in the groundwater-flow systems in the NAWQA case-study basins. The summaries of water-development history, hydrogeology, conceptual understanding of the groundwater system under both predevelopment and modern conditions, and effects of natural and human-related factors on groundwater quality presented in the sections on each basin also serve as a foundation for the synthesis and modeling phases of the SWPA regional study.
NASA Technical Reports Server (NTRS)
Prisk, G. K.; Guy, Harold J. B.; Elliott, Ann R.; Deutschman, Robert A., III; West, John B.
1993-01-01
We measured pulmonary diffusing capacity (DL), diffusing capacity per unit lung volume, pulmonary capillary blood volume (Vc), membrane diffusing capacity (Dm), pulmonary capillary blood flow or cardiac output (Qc), and cardiac stroke volume (SV) in four subjects exposed to nine days of microgravity. DL in microgravity was elevated compared with preflight standing values and was higher than preflight supine because of the elevation of both Vc and Dm. The elevation in Vc was comparable to that measured supine in 1 G, but the increase in Dm was in sharp contrast to the supine value. We postulate that, in 0 G, pulmonary capillary blood is evenly distributed throughout the lung, providing for uniform capillary filling, leading to an increase in the surface area available for diffusion. By contrast, in the supine 1-G state, the capillaries are less evenly filled, and although a similar increase in blood volume is observed, the corresponding increase in surface area does not occur. DL and its subdivisions showed no adaptive changes from the first measurement 24 h after the start of 0 G to eight days later. Similarly, there were no trends in the postflight data, suggesting that the principal mechanism of these changes was gravitational. The increase in Dm suggests that subclinical pulmonary edema did not result from exposure to 0 G. Qc was modestly increased inflight and decreased postflight compared with preflight standing. Compared with preflight standing, SV was increased 46 percent inflight and decreased 14 percent in the 1st week postflight. There were temporal changes in Qc and SV during 0 G, with the highest values recorded at the first measurement, 24 h into the flight. The lowest values of Qc and SV occurred on the day of return.
Degiovanni, Anna; Boggio, Enrico; Prenna, Eleonora; Sartori, Chiara; De Vecchi, Federica; Marino, Paolo N
2018-04-01
Diastolic dysfunction promotes atrial fibrillation (AF) inducing left atrial (LA) remodeling, with chamber dilation and fibrosis. Predominance of LA phasic conduit (LAC) function should reflect not only chamber alterations but also underlying left ventricular (LV) filling impairment. Thus, LAC was tested as possible predictor of early AF relapse after electrical cardioversion (EC). 96 consecutive patients, who underwent EC for persistent non-valvular AF, were prospectively enrolled. Immediately after successful EC (3 h ± 15 min), an echocardiographic apical four-chamber view was acquired with transmitral velocities, annular tissue Doppler and simultaneous LV and LA three-dimensional full-volume datasets. Then, from LA-LV volumetric curves we computed LAC as: [(LV maximum - LV minimum) - (LA maximum - LA minimum) volume], expressed as % LV stroke volume. LA pump, immediately post-EC, was assumed and verified as being negligible. Sinus rhythm persistence at 1 month was checked with ECG-Holter monitoring. At 1 month 62 patients were in sinus rhythm and 34 in AF. AF patients presented pre-EC higher E/é values (p = 0.012), no major LA volume differences (p = NS), but a stiffer LV cavity (p = 0.012) for a comparable LV capacitance (p = 0.461). Conduit contributed more (p < 0.001) to LV stroke volume in AF subpopulation. Multiple regression revealed LAC as the most significant AF predictor (p = 0.013), even after correction for biometric characteristics and pharmacotherapy (p = 0.008). Our data suggest that LAC larger contribution to LV filling soon after EC reflects LA-LV stiffening, which skews atrioventricular interaction leading to AF perpetuation and makes conduit dominance a powerful predictor of early AF recurrence.
Effects of pore volume-transmissivity correlation on transport phenomena.
Lunati, Ivan; Kinzelbach, Wolfgang; Sørensen, Ivan
2003-12-01
The relevant velocity that describes transport phenomena in a porous medium is the pore velocity. For this reason, one needs not only to describe the variability of transmissivity, which fully determines the Darcy velocity field for given source terms and boundary conditions, but also any variability of the pore volume. We demonstrate that hydraulically equivalent media with exactly the same transmissivity field can produce dramatic differences in the displacement of a solute if they have different pore volume distributions. In particular, we demonstrate that correlation between pore volume and transmissivity leads to a much smoother and more homogeneous solute distribution. This was observed in a laboratory experiment performed in artificial fractures made of two plexiglass plates into which a space-dependent aperture distribution was milled. Using visualization by a light transmission technique, we observe that the solute behaviour is much smoother and more regular after the fractures are filled with glass powder, which plays the role of a homogeneous fault gouge material. This is due to a perfect correlation between pore volume and transmissivity that causes pore velocity to be not directly dependent on the transmissivity, but only indirectly through the hydraulic gradient, which is a much smoother function due to the diffusive behaviour of the flow equation acting as a filter. This smoothing property of the pore volume-transmissivity correlation is also supported by numerical simulations of tracer tests in a dipole flow field. Three different conceptual models are used: an empty fracture, a rough-walled fracture filled with a homogeneous material and a parallel-plate fracture with a heterogeneous fault gouge. All three models are hydraulically equivalent, yet they have a different pore volume distribution. Even if piezometric heads and specific flow rates are exactly the same at any point of the domain, the transport process differs dramatically. These differences make it important to discriminate in situ among different conceptual models in order to simulate correctly the transport phenomena. For this reason, we study the solute breakthrough and recovery curves at the extraction wells. Our numerical case studies show that discrimination on the basis of such data might be impossible except under very favourable conditions, i.e. the integral scale of the transmissivity field has to be known and small compared to the dipole size. If the latter conditions are satisfied, discrimination between the rough-walled fracture filled with a homogeneous material and the other two models becomes possible, whereas the parallel-plate fracture with a heterogeneous fault gouge and the empty fracture still show identifiability problems. The latter may be solved by inspection of aperture and pressure testing.
Aricak, Burak
2015-07-01
Forest roads are essential for transport in managed forests, yet road construction causes environmental disturbance, both in the surface area the road covers and in erosion and downslope deposition of road fill material. The factors affecting the deposition distance of eroded road fill are the slope gradient and the density of plant cover. Thus, it is important to take these factors into consideration during road planning to minimize their disturbance. The aim of this study was to use remote sensing and field surveying to predict the locations that would be affected by downslope deposition of eroding road fill and to compile the data into a geographic information system (GIS) database. The construction of 99,500 m of forest roads is proposed for the Kastamonu Regional Forest Directorate in Turkey. Using GeoEye satellite images and a digital elevation model (DEM) for the region, the location and extent of downslope deposition of road fill were determined for the roads as planned. It was found that if the proposed roads were constructed by excavators, the fill material would cover 910,621 m(2) and the affected surface area would be 1,302,740 m(2). Application of the method used here can minimize the adverse effects of forest roads.
Food-Web Models Predict Species Abundances in Response to Habitat Change
Gotelli, Nicholas J; Ellison, Aaron M
2006-01-01
Plant and animal population sizes inevitably change following habitat loss, but the mechanisms underlying these changes are poorly understood. We experimentally altered habitat volume and eliminated top trophic levels of the food web of invertebrates that inhabit rain-filled leaves of the carnivorous pitcher plant Sarracenia purpurea. Path models that incorporated food-web structure better predicted population sizes of food-web constituents than did simple keystone species models, models that included only autecological responses to habitat volume, or models including both food-web structure and habitat volume. These results provide the first experimental confirmation that trophic structure can determine species abundances in the face of habitat loss. PMID:17002518
Asheibi, Fatma; Qualtrough, Alison J E; Mellor, Anthony; Withers, Philip J; Lowe, Tristan
2014-01-01
This study compares the effectiveness of ProTaper rotary files with ProTaper retreatment and K-files in the removal of Resilon or gutta percha (GP) from canals filled either by cold lateral condensation or thermal obturation using micro-CT. Ninety-six teeth were prepared using ProTaper files and allocated into four groups (n=24): Group-1 was filled with GP/AH-Plus and Group-2 with Resilon/RealSeal using cold lateral condensation. Group-3 was filled with GP/AH-Plus and Group-4 with Resilon/RealSeal using System B and Obtura II. The roots were scanned by micro-CT. Each group was divided into two subgroups (n=12): A, retreated using ProTaper files and B, using ProTaper retreatment and K-files. The roots were scanned to calculate the volume of the remaining material. With thermal obturation, roots filled with Resilon had significantly more remaining material than GP. Obturation using thermal technique resulted in significantly less remaining material than cold condensation except Resilon retreated using ProTaper retreatment and K-files.
System for loading slab-gel holders for electrophoresis separation
Anderson, Norman G.; Anderson, Norman L.
1979-01-01
A slab-gel loading system includes a prismatic chamber for filling a plurality of slab-gel holders simultaneously. Each slab-gel holder comprises a pair of spaced apart plates defining an intermediate volume for gel containment. The holders are vertically positioned in the chamber with their major surfaces parallel to the chamber end walls. A liquid inlet is provided at the corner between the bottom and a side wall of the chamber for distributing a polymerizable monomer solution or a coagulable colloidal solution into each of the holders. The chamber is rotatably supported so that filling can begin with the corner having the liquid inlet directed downwardly such that the solution is gently funneled upwardly, without mixing, along the diverging side and bottom surfaces. As filling proceeds, the chamber is gradually rotated to position the bottom wall in a horizontal mode. The liquid filling means includes a plastic envelope with a septum dividing it into two compartments for intermixing two solutions of different density and thereby providing a liquid flow having a density gradient. The resulting gels have a density gradient between opposite edges for subsequent use in electrophoresis separations.
Brueckner, David; Roesti, David; Zuber, Ulrich; Sacher, Meik; Duncan, Derek; Krähenbühl, Stephan; Braissant, Olivier
2017-05-15
Tunable diode laser absorption spectroscopy (TDLAS) was evaluated on its potential to detect bacterial growth of contaminated media fill vials. The target was a replacement/ automation of the traditional visual media fill inspection. TDLAS was used to determine non-invasively O 2 and/or CO 2 changes in headspaces of such vials being induced by metabolically active microorganisms. Four different vial formats, 34 microorganisms (inoculation volume<10 cells) and two different media (TSB/FTM) were tested. Applying parallel CO 2 and O 2 headspace measurements all format-organism combinations were detected within <11 days reliably with reproducible results. False negatives were exclusively observed for samples that were intentionally breached with syringes of 0.3mm in diameter. Overall it was shown that TDLAS functionality for a replacement of the visual media fill inspection is given and that investing in further validation and implementation studies is valuable. Nevertheless, some small but vincible challenges remain to have this technology in practical use. Copyright © 2017 Elsevier B.V. All rights reserved.
Solute-Filled Syringe For Formulating Intravenous Solution
NASA Technical Reports Server (NTRS)
Owens, Jim; Bindokas, AL; Dudar, Tom; Finley, Mike; Scharf, Mike
1993-01-01
Prefilled syringe contains premeasured amount of solute in powder or concentrate form used to deliver solute to sterile interior of large-volume parenteral (LVP) bag. Predetermined amount of sterile water also added to LVP bag through sterilizing filter, and mixed with contents of syringe, yielding sterile intravenous solution of specified concentration.
Child and Adolescent Development for Educators
ERIC Educational Resources Information Center
Pressley, Michael; McCormick, Christine B.
2006-01-01
Filling a tremendous need, this is the first graduate-level child development text written specifically for future educators. The volume provides a solid understanding of major theories of development, focusing on how each has informed research and practice in educational contexts. Topics include the impact of biology and early experiences on the…
Fluency Instruction. Research-Based Best Practices
ERIC Educational Resources Information Center
Rasinski, Timothy Ed.; Blachowicz, Camille Ed.; Lems, Kristin Ed.
2006-01-01
Because fluency instruction was identified, only recently, as a cornerstone literacy subject--it is still unfamiliar terrain for many teachers. This volume fills a crucial gap by offering a thorough, authoritative examination of what reading fluency is--and how it should be taught. Contributing authors, who include the field's leading authorities,…
Mittal, Neelam; Jain, Jyoti
2014-01-01
The purpose of this study was to evaluate the efficacy of nickel-titanium rotary retreatment systems versus stainless steel hand retreatment system with or without solvent for gutta-percha removal during retreatment. Sixty extracted human mandibular molar teeth with single canal in a distal root was prepared with ProTaper rotary nickel-titanium files and obturated with gutta-percha and sealer. The teeth were randomly divided into six groups of 10 specimens in each groups. The volume of filling material before and after retreatment were evaluated in cm(3) using the computed tomography (CT) scanner proprietary software. Maximum amount of filling material removed during retreatment with ProTaper retreatment system with solvent and minimum with hand retreatment system with solvent. None of the technique was 100% effective in removing the filling materials, but the ProTaper retreatment system with solvent was better.
A hybrid six-dimensional muon cooling channel using gas filled rf cavities
Stratakis, D.
2017-09-25
We describe an alternative cooling approach to prevent rf breakdown in magnetic fields that simultaneously reduces all six phase-space dimensions of a muon beam. In this process, cooling is accomplished by reducing the beam momentum through ionization energy loss in discrete absorbers and replenishing the momentum loss only in the longitudinal direction through gas-filled rf cavities. The advantage of gas filled cavities is that they can run at high gradients in magnetic fields without breakdown. Using this approach, we show that our channel can achieve a decrease of the 6-dimensional phase-space volume by several orders of magnitude. With the aidmore » of numerical simulations, we demonstrate that the transmission of our proposed channel is comparable to that of an equivalent channel with vacuum rf cavities. Finally, we discuss the sensitivity of the channel performance to the choice of gas and operating pressure.« less
A hybrid six-dimensional muon cooling channel using gas filled rf cavities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stratakis, D.
We describe an alternative cooling approach to prevent rf breakdown in magnetic fields that simultaneously reduces all six phase-space dimensions of a muon beam. In this process, cooling is accomplished by reducing the beam momentum through ionization energy loss in discrete absorbers and replenishing the momentum loss only in the longitudinal direction through gas-filled rf cavities. The advantage of gas filled cavities is that they can run at high gradients in magnetic fields without breakdown. Using this approach, we show that our channel can achieve a decrease of the 6-dimensional phase-space volume by several orders of magnitude. With the aidmore » of numerical simulations, we demonstrate that the transmission of our proposed channel is comparable to that of an equivalent channel with vacuum rf cavities. Finally, we discuss the sensitivity of the channel performance to the choice of gas and operating pressure.« less
Analyses of mode filling factor of a laser end-pumped by a LD with high-order transverse modes
NASA Astrophysics Data System (ADS)
Han, Juhong; Wang, You; An, Guofei; Rong, Kepeng; Yu, Hang; Wang, Shunyan; Zhang, Wei; Cai, He; Xue, Liangping; Wang, Hongyuan; Zhou, Jie
2017-05-01
Although the concept of the mode filling factor (also named as "mode-matching efficiency") has been well discussed decades before, the concept of so-called overlap coefficient is often confused by the laser technicians because there are several different formulae for various engineering purposes. Furthermore, the LD-pumped configurations have become the mainstream of solid-state lasers since their compact size, high optical-to-optical efficiency, low heat generation, etc. As the beam quality of LDs are usually very unsatisfactory, it is necessary to investigate how the mode filling factor of a laser system is affected by a high-powered LD pump source. In this paper, theoretical analyses of an end-pumped laser are carried out based on the normalized overlap coefficient formalism. The study provides a convenient tool to describe the intrinsically complex issue of mode interaction corresponding to a laser and an end-pumped source. The mode filling factor has been studied for many cases in which the pump mode and the laser mode have been considered together in the calculation based on analyses of the rate equations. The results should be applied for analyses of any other types of lasers with the similar optical geometry.
Educational Brief: Using Space for a Better Foundation on Earth Mechanics of Granular Materials
NASA Technical Reports Server (NTRS)
Dooling, Dave (Editor)
2002-01-01
Soils are three-phase composite materials that consist of soil, solid particles, and voids filled with water and/or air. Based on the particle-size distribution, they are generally classified as fine-grained (clays and plastic silts) and coarse-grained soils (nonplastic silts, sand, and gravel). Soil's resistance to external loadings is mainly derived from friction between particles and cohesion. Friction resistance is due to particles' surface-to-surface friction, interlocking, crushing, rearrangement, and dilation (or expansion) during shearing. Cohesion can be due to chemical cementation between particles, electrostatic and electromagnetic forces, and soil-water reaction and equilibrium. The basic factor responsible for the strength of coarse-grained soils is friction. Cohesion can be ignored. This educational brief focuses on measuring shear strength of sands (typical example of coarse-grained soils) where, for the same material, packing density is a main factor to be considered when one asks about the shear strength value. As the external load is applied, the soil's resistance is attained through shearing resistance, which causes the soil volume to increase (expand) or decrease (compress) depending on the initial packing density.
The Particle Distribution in Liquid Metal with Ceramic Particles Mould Filling Process
NASA Astrophysics Data System (ADS)
Dong, Qi; Xing, Shu-ming
2017-09-01
Adding ceramic particles in the plate hammer is an effective method to increase the wear resistance of the hammer. The liquid phase method is based on the “with the flow of mixed liquid forging composite preparation of ZTA ceramic particle reinforced high chromium cast iron hammer. Preparation method for this system is using CFD simulation analysis the particles distribution of flow mixing and filling process. Taking the 30% volume fraction of ZTA ceramic composite of high chromium cast iron hammer as example, by changing the speed of liquid metal viscosity to control and make reasonable predictions of particles distribution before solidification.
Mara, Leo M.
1999-01-01
Disclosed are improvments to a rapid road repair vehicle comprising an improved cleaning device arrangement, two dispensing arrays for filling defects more rapidly and efficiently, an array of pre-heaters to heat the road way surface in order to help the repair material better bond to the repaired surface, a means for detecting, measuring, and computing the number, location and volume of each of the detected surface imperfection, and a computer means schema for controlling the operation of the plurality of vehicle subsystems. The improved vehicle is, therefore, better able to perform its intended function of filling surface imperfections while moving over those surfaces at near normal traffic speeds.
A potential nuclear magnetic resonance imaging approach for noncontact temperature measurement
NASA Technical Reports Server (NTRS)
Manatt, Stanley L.
1989-01-01
It is proposed that in a nuclear magnetic resonance (NMR) imaging experiment that it should be possible to measure temperature through an extended volume. The basis for such a measurement would depend upon sensing a temperature dependent on NMR parameter in an inert, volatile molecule (or fluid) filling the volume of interest. Exploratory work suggest that one suitable candidate for such a purpose might be CH3Cl. Possible parameters, other inert gases and feasible measurement schemes that might provide such temperature measurement are discussed.
Blood filling and flow in lungs during change in body position in space
NASA Technical Reports Server (NTRS)
Pogodin, A. S.; Mazhbich, B. I.
1980-01-01
In the horizontal position (supine and lateral), in the upright position (head up and head down) and during change of the cat body position in space, quantitative responses of regional blood volume and blood flow in the lungs (ml/100 cu cm) revealed presence of the gradient in the gravitation direction. Blood volume and blood flow of different lung portions changed qualitatively and quantitatively in different ways. These changes occurred only in the direction producing the equality of regional hydrostatical and hemodynamic loads in the lungs at either horizontal level.
Construction of a test embankment using a sand-tire shred mixture as fill material.
Yoon, Sungmin; Prezzi, Monica; Siddiki, Nayyar Zia; Kim, Bumjoo
2006-01-01
Use of tire shreds in construction projects, such as highway embankments, is becoming an accepted way of beneficially recycling scrap tires. However, in the last decade there was a decline in the use of pure tire shreds as fill materials in embankment construction, as they are susceptible to fire hazards due to the development of exothermic reactions. Tire shred-sand mixtures, on the other hand, were found to be effective in inhibiting exothermic reactions. When compared with pure tire shreds, tire shred-sand mixtures are less compressible and have higher shear strength. However, the literature contains limited information on the use of tire shred-soil mixtures as a fill material. The objectives of this paper are to discuss and evaluate the feasibility of using tire shred-sand mixtures as a fill material in embankment construction. A test embankment constructed using a 50/50 mixture, by volume, of tire shreds and sand was instrumented and monitored to: (a) determine total and differential settlements; (b) evaluate the environmental impact of the embankment construction on the groundwater quality due to leaching of fill material; and (c) study the temperature variation inside the embankment. The findings in this research indicate that mixtures of tire shreds and sand are viable materials for embankment construction.
Improved OCT imaging of lung tissue using a prototype for total liquid ventilation
NASA Astrophysics Data System (ADS)
Schnabel, Christian; Meissner, Sven; Koch, Edmund
2011-06-01
Optical coherence tomography (OCT) is used for imaging subpleural alveoli in animal models to gain information about dynamic and morphological changes of lung tissue during mechanical ventilation. The quality of OCT images can be increased if the refraction index inside the alveoli is matched to the one of tissue via liquid-filling. Thereby, scattering loss can be decreased and higher penetration depth and tissue contrast can be achieved. Until now, images of liquid-filled lungs were acquired in isolated and fixated lungs only, so that an in vivo measurement situation is not present. To use the advantages of liquid-filling for in vivo imaging of small rodent lungs, it was necessary to develop a liquid ventilator. Perfluorodecalin, a perfluorocarbon, was selected as breathing fluid because of its refraction index being similar to the one of water and the high transport capacity for carbon dioxide and oxygen. The setup is characterized by two independent syringe pumps to insert and withdraw the fluid into and from the lung and a custom-made control program for volume- or pressure-controlled ventilation modes. The presented results demonstrate the liquid-filling verified by optical coherence tomography and intravital microscopy (IVM) and the advantages of liquid-filling to OCT imaging of subpleural alveoli.
Jan, Kulsum; Riar, C S; Saxena, D C
2015-12-01
Different agro-industrial wastes were mixed with different plasticizers and extruded to form the pellets to be used further for development of biodegradable molded pots. Bulk density and macro-porosity are the important engineering properties used to determine the functional characteristics of the biodegradable pellets viz., expansion volume, water solubility, product colour, flowability and compactness. Significant differences in the functional properties of pellets with varying bulk densities (loose and tapped) and macro-porosities (loose, tapped) were observed. The observed mean bulk density of biodegradable pellets made from different formulations ranged between 0.213 and 0.560 g/ml for loose fill conditions and 0.248 to 0.604 g/ml for tapped fill conditions. Biodegradable pellets bear a good compaction for both loose and tapped fill methods. The mean macro-porosity of biodegradable pellets ranged between 1.19 and 54.48 % for loose fill condition and 0.29 to 53.35 % for tapped fill condition. Hausner ratio (HR) for biodegradable pellets varied from 1.026 to 1.328, indicating a good flowability of biodegradable pellets. Pearson's correlation between engineering properties and functional properties of biodegradable pellets revealed that from engineering properties functional properties can be predicted.
Shi, Yu; Chen, Mao-xue; Yu, Zhen-wen; Xu, Zhen-zhu
2011-10-01
Taking three wheat cultivars Jimai 20 (strong gluten), Taishan 23 (medium gluten), and Ningmai 9 (weak gluten) as test materials, a field experiment was conducted to examine the effects of shading at different phases of grain-filling on the grain protein components contents and processing quality. Four treatments were installed, i. e., no shading (S0), shading at early grain-filling phase (from 0 day after anthesis (DAA) to 11 DAA; S1), shading at medium grain-filling phase (from 12 DAA to 23 DAA; S2), and shading at late grain-filling phase (from 24 DAA to 35 DAA; S3). No significant differences were observed in the grain albumin+globulin contents of the three cultivars among the four treatments. Shading increased the grain HMW-GS, LMW-GS, gluten, glutenin, and total protein contents of Jimai 20 and Taishan 23 significantly, and the increments were higher in treatment S2 than in other shading treatments. Treatments S2 and S3 increased the grain protein components contents of Ningmai 9 significantly. Comparing with the control, shading decreased the grain yield significantly, but increased the dough development time, dough stability time, and sedimentation volume, especially for treatment S2, which suggested that the wheat grain quality had a close relationship with the light intensity at medium phase of grain-filling. Overall, the regulation effect of shading at grain-filling stage on the wheat grain yield, grain protein components contents, and indices values of grain processing quality for the test cultivars was in the order of Jimai 20 > Taishan 23 > Ningmai 9.
Bulk viscosity of water in acoustic modal analysis and experiment
NASA Astrophysics Data System (ADS)
Kůrečka, Jan; Habán, Vladimír; Himr, Daniel
2018-06-01
Bulk viscosity is an important factor in the damping properties of fluid systems and exhibits frequency dependent behaviour. A comparison between modal analysis in ANSYS Acoustics, custom code and experimental data is presented in this paper. The measured system consists of closed ended water-filled steel pipes of different lengths. The influence of a pipe wall, flanges on both ends and longitudinal waves in the structural part were included in measurement evaluation. Therefore, the obtained values of sound speed and bulk viscosity are parameters of the fluid. A numerical simulation was carried out only using fluid volume in a range of bulk viscosity. Damping characteristics in this range were compared to measured values. The results show a significant influence of sound speed and subsequently, the use of sound speed value regressed from experimental data yields a better fit between the measurement and the computation.
Pillar-structured neutron detector based multiplicity system
Murphy, John W.; Shao, Qinghui; Voss, Lars F.; ...
2017-10-04
This work demonstrates the potential of silicon pillars filled with boron-10 as a sensor technology for a compact and portable neutron multiplicity system. Solid-state, semiconductor based neutron detectors may enable completely new detector form factors, offer an alternate approach to helium-3 based systems, and reduce detector weight and volume requirements. Thirty-two pillar-structured neutron detectors were assembled into a system with an active area of over 20 cm 2 and were used in this work to demonstrate the feasibility of this sensor technology as a potential replacement for helium-3 based gas detectors. Multiplicity measurements were successfully carried out using a californium-252more » neutron source, in which the source mass, system efficiency, and die-away time were determined. As a result, this demonstration shows that these solid-state detectors could allow for a more compact and portable system that could be used for special nuclear material identification in the field.« less
Respiratory factors in the uptake and excretion of anesthetics. 1965.
Epstein, R M; Papper, E M
1998-01-01
We have considered some of the ways in which respiration can affect the gas exchange process. The simplest relationships are purely physical and relate to the speed with which the lung and tissues can be filled or emptied. More complex relationships involve a consideration of the interplay between blood and gas in the lung and the effects of gas exchange on respiratory volumes themselves. Finally, some examples of the importance of physiologic alteration produced by, and producing respiratory shifts during, gas uptake processes were presented briefly. The detailed interpretation of gas exchange phenomena demands more quantitative information of this sort, concerning not only the respiratory but the circulatory and tissue level variations affecting uptake during anesthesia. Nevertheless, understanding of the principles and application of such data as are available can go far toward removing the handicaps of empirical practice from the day-to-day administration of anesthetic agents to human beings.
Development of Water Softening Method of Intake in Magnitogorsk
NASA Astrophysics Data System (ADS)
Meshcherova, E. A.; Novoselova, J. N.; Moreva, J. A.
2017-11-01
This article contains an appraisal of the drinking water quality of Magnitogorsk intake. A water analysis was made which led to the conclusion that the standard for general water hardness was exceeded. As a result, it became necessary to develop a number of measures to reduce water hardness. To solve this problem all the necessary studies of the factors affecting the value of increased water hardness were carried out and the water softening method by using an ion exchange filter was proposed. The calculation of the cation-exchanger filling volume of the proposed filter is given in the article, its overall dimensions are chosen. The obtained calculations were confirmed by the results of laboratory studies by using the test installation. The research and laboratory tests results make the authors conclude that the proposed method should be used to obtain softened water for the requirements of SanPin.
Clarkson, Douglas McG; Manna, Avinish; Hero, Mark
2014-02-01
We describe the use of an analytical weighing balance of measurement accuracy 0.00001g for determination of concentrations of perfluropropane (C3F8) gas used in ophthalmic surgical vitrectomy procedures. A range of test eyes corresponding to an eye volume of 6.1ml were constructed using 27 gauge needle exit ducts and separately 20 gauge (straight) and 23 gauge (angled) entrance ports. This method allowed determination of concentration levels in the sample preparation syringe and also levels in test eyes. It was determined that a key factor influencing gas concentrations accuracy related to the method of gas fill and the value of dead space of the gas preparation/delivery system and with a significant contribution arising from the use of the particle filter. The weighing balance technique was identified as an appropriate technique for estimation of gas concentrations. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.
Multiple impacts of dusty projectiles
NASA Astrophysics Data System (ADS)
Kothe, Stefan; Güttler, Carsten; Blum, Jurgen
In the context of early stages of planetesimal formation we performed laboratory and drop tower experiments to study multiple impacts of small dust-aggregate projectiles into solid sintered dust targets. Both collision partners consisted of 1.5 µm monodisperse spherical SiO2 monomers with volume filling factors of 0.15 (projectiles) and 0.35 (targets), respectively. The fragile projectiles were accelerated by a solenoid accelerator with a linear projectile magazine, which enabled us to perform 25 impacts within 4.5 s of microgravity time in the Bremen drop tower. We measured the mass-accretion efficiency for different impact velocities between 3 and 5 m s-1 , using an analytical balance and imaging methods. Furthermore, we observed random collisions among small dust aggregates with sizes around 1 mm and collision velocities of the order of 0.25 m s-1 and used them to improve the dust-aggregate collision model of Güttler et al. (2010). u
The behavior of delaminations in composite materials - experimental results
NASA Astrophysics Data System (ADS)
Chermoshentseva, A. S.; Pokrovskiy, A. M.; Bokhoeva, L. A.
2016-02-01
Delamination is one of the most common failure modes of composite materials. It may occur as a consequence of imperfections in the production process or the effects of external factors during the operational life of the composite laminates, such as the impact by foreign objects. This paper presents the results of mechanical tests and the optimum degrees of filling the composite materials (CM) with hydrophobic powder (Tarkosil T-20) depending on the latter mass concentration. The results present test samples of the CM with the underlying interlayer defects. The samples were fabricated of twenty-ply pre-preg (fiberglass or carbon fiber). The industrial grade glass is T-25 (VM) specification 6-11-380-76. The composite materials have nanosized additives in structure. The volume concentration of nanopowders is varying from 0.1% to 0.5%. This kind of research has been done for the first time.
Pillar-structured neutron detector based multiplicity system
NASA Astrophysics Data System (ADS)
Murphy, John W.; Shao, Qinghui; Voss, Lars F.; Kerr, Phil L.; Fabris, Lorenzo; Conway, Adam M.; Nikolic, Rebecca J.
2018-01-01
This work demonstrates the potential of silicon pillars filled with boron-10 as a sensor technology for a compact and portable neutron multiplicity system. Solid-state, semiconductor based neutron detectors may enable completely new detector form factors, offer an alternate approach to helium-3 based systems, and reduce detector weight and volume requirements. Thirty-two pillar-structured neutron detectors were assembled into a system with an active area of over 20 cm2 and were used in this work to demonstrate the feasibility of this sensor technology as a potential replacement for helium-3 based gas detectors. Multiplicity measurements were successfully carried out using a californium-252 neutron source, in which the source mass, system efficiency, and die-away time were determined. This demonstration shows that these solid-state detectors could allow for a more compact and portable system that could be used for special nuclear material identification in the field.
Filling defects in the pancreatic duct on endoscopic retrograde pancreatography.
Taylor, A J; Carmody, T J; Schmalz, M J; Wiedmeyer, D A; Stewart, E T
1992-12-01
Filling defects in the pancreatic duct are a frequent finding during endoscopic retrograde pancreatography (ERP) and have a variety of causes. Some filling defects may be artifactual or related to technical factors and, once their origin is recognized, can be disregarded. Others may be due to acute changes of pancreatitis and should prompt more careful injection of contrast material into the duct. Intraluminal masses may represent calculi or a neoplasm, either of which may require surgery or endoscopic intervention. The exact nature of these filling defects may not be apparent on radiographs, and other studies may be needed. This article reviews our approach to the evaluation of filling defects in the pancreatic duct.
Spiegelman, M
1966-06-01
The plan calls for monographs on 16 specific topics and a review volume. The specific topics include a monograph on fertility, another on marriage and divorce, and one on social and economic factors in mortality, all of which are of obvious demographic interest. The core of the development of the monographs dealing with the disease topics, and accidents, homicide, and suicide, is a tabulation program involving specific and age-adjusted death rates based upon the deaths in the United States for the three year period 1959-61 and the 1960 census of population. The program called for a set of standard tabulations common to each monograph and also a set of special tabulations tailored to meet the particular needs for each topic as specified by its authors. This wealth of demographic detail regarding mortality in the United States during 1959-61 fills only one aspect of its health picture. To fill out the health picture, use is being made of the great volume of morbidity data out of the National Health Interview and Examination Surveys and a wide variety of other specialized surveys. In all of these, the findings are invariably described in terms of the demographic characteristics of age and sex, and frequently in terms of such social-economic variables as education, income, work status, and occupational class.A large part of the content of the monograph on social and economic factors in mortality will come out of available results of the 1960 census-death certificate matching study at the University of Chicago. One important feature of this monograph, not contained in the Chicago study, is a regression and correlation analysis of total mortality in 202 Standard Metropolitan Statistical Areas in relation to a large number of social, economic, and climatic factors. Among the features in the monograph on fertility are chapters on the medical and biological characteristics of births, fecundity and family planning, and an analysis of cohort fertility trends. The monograph on marriage and divorce will make use of the detailed tabulations from the 1960 census on marital status in relation to education, race, parentage, earnings and other classifications of individuals and of husband and wife in married couples. It will also contain a matching study of divorce records in certain states for a short period before the census of 1960 with the returns in the census. The project is supported by a grant from the United States Public Health Service (CH 00075; formerly RG 08262). Publication will be by the Harvard University Press.
Himalayan Lake- and River-Impacting Landslides and Ice Avalanches: Some So Deadly, Some No Problem
NASA Astrophysics Data System (ADS)
Kargel, J. S.; Karki, A.; Haritashya, U. K.; Shugar, D. H.; Harrison, S.
2017-12-01
Scientific attention to landslides and ice avalanches in Nepal was heightened by the 2015 Gorkha earthquake. However, landslides and ice avalanches— some deadly— are frequent in this mountainous, glacierized country and across High Mountain Asia. River blocking landslides (RBLs) often create dangerous situations due to upstream impoundments and downstream landslide dammed outburst floods (LDOFs). Factors affecting RBL hazards include: Volumes and masses of ice, rock, and water; shape factors of the valley and landslide; grain size-frequency distribution; river hydrograph; and seasonal and weather factors. These factors affect processes such as slumping and erosion of the RBL by overflow or piping, buoyant lifting of dam material, melting of a landslide ice core, liquefaction, overfill overtopping or tsunami overtopping by subsequent landslides into the impoundment, and the volume and peak discharge of an LDOF. Not all processes aggravate hazards; a high ice:rock ratio, for example, can result in immediate tunneling by the river with no subsequent impoundment. A dam composed of mainly boulders with few fines likewise can prevent effective damming; however, a wide spectrum of the particle-size-distribution can make a long-lasting, benign dam. The most hazardous RBLs include those creating large dams and rapidly-filled impoundments, but which can rapidly and catastrophically break up, especially at sites of repeated terrain collapses. The particle size-frequency of a landslide dam depends substantially on bedrock lithology and structure. Vulnerabilities and warning times also affect whether an upstream impoundment flood or LDOF will exert a large toll. For landslide susceptibility assessments, usual treatments involving mountain slopes, valley shape, and seismic activity should be complemented by quantitative measures of bedrock lithology and weathering state, the potential energy and distribution of unstable masses, and recorded historic or prehistoric RBLs in the same area. Factors for landslide triggering of glacial lake outburst floods (GLOFs) include some of the same factors, but the mass/energy input rate into the lake, the lake's shape and length, and moraine dam properties are also important in GLOF triggering. Himalayan examples will illustrate some hazard factors.
Fujimoto, Naoki; Prasad, Anand; Hastings, Jeffrey L.; Arbab-Zadeh, Armin; Bhella, Paul S.; Shibata, Shigeki; Palmer, Dean; Levine, Benjamin D.
2013-01-01
Background Healthy but sedentary aging leads to cardiovascular stiffening, whereas life-long endurance training preserves left ventricular (LV) compliance. However, it is unknown whether exercise training started later in life can reverse the effects of sedentary behavior on the heart. Methods and Results Twelve sedentary seniors and 12 Masters athletes were thoroughly screened for comorbidities. Subjects underwent invasive hemodynamic measurements with pulmonary artery catheterization to define Starling and LV pressure-volume curves; secondary functional outcomes included Doppler echocardiography, magnetic resonance imaging assessment of cardiac morphology, arterial stiffness (total aortic compliance and arterial elastance), and maximal exercise testing. Nine of 12 sedentary seniors (70.6±3 years; 6 male, 3 female) completed 1 year of endurance training followed by repeat measurements. Pulmonary capillary wedge pressures and LV end-diastolic volumes were measured at baseline, during decreased cardiac filling with lower-body negative pressure, and increased filling with saline infusion. LV compliance was assessed by the slope of the pressure-volume curve. Before training, V̇O2max, LV mass, LV end-diastolic volume, and stroke volume were significantly smaller and the LV was less compliant in sedentary seniors than Masters athletes. One year of exercise training had little effect on cardiac compliance. However, it reduced arterial elastance and improved V̇O2 max by 19% (22.8±3.4 versus 27.2± 4.3 mL/kg/mL; P<0.001). LV mass increased (10%, 64.5±7.9 versus 71.2±12.3 g/m2; P=0.037) with no change in the mass-volume ratio. Conclusions Although 1 year of vigorous exercise training did not appear to favorably reverse cardiac stiffening in sedentary seniors, it nonetheless induced physiological LV remodeling and imparted favorable effects on arterial function and aerobic exercise capacity. PMID:20956204
Using Temporal Fill Factor to Reduce Frame Reconstruction Rates
NASA Technical Reports Server (NTRS)
Larimer, James; Balram, Nikhil; Gille, Jennifer; Luszcz, Jeffery
1997-01-01
The newer active matrix display technologies such as TFT-LCD, DMD, PDP maintain their pixel values through the entire frame time, presenting a 100% temporal fill factor, in contrast to the duty cycle produced by the phosphor impulse response of the CRT. This sample-and-hold characteristic can be exploited to lower the displayed frame rate without affecting visual quality. The lower frame rate results in significantly lower transmission bandwidth, power, and cost.
Rear surface effects in high efficiency silicon solar cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wenham, S.R.; Robinson, S.J.; Dai, X.
1994-12-31
Rear surface effects in PERL solar cells can lead not only to degradation in the short circuit current and open circuit voltage, but also fill factor. Three mechanisms capable of changing the effective rear surface recombination velocity with injection level are identified, two associated with oxidized p-type surfaces, and the third with two dimensional effects associated with a rear floating junction. Each of these will degrade the fill factor if the range of junction biases corresponding to the rear surface transition, coincides with the maximum power point. Despite the identified non idealities, PERL cells with rear floating junctions (PERF cells)more » have achieved record open circuit voltages for silicon solar cells, while simultaneously achieving fill factor improvements relative to standard PERL solar cells. Without optimization, a record efficiency of 22% has been demonstrated for a cell with a rear floating junction. The results of both theoretical and experimental studies are provided.« less
NASA Astrophysics Data System (ADS)
Gasparini, Nicola; Jiao, Xuechen; Heumueller, Thomas; Baran, Derya; Matt, Gebhard J.; Fladischer, Stefanie; Spiecker, Erdmann; Ade, Harald; Brabec, Christoph J.; Ameri, Tayebeh
2016-09-01
In recent years the concept of ternary blend bulk heterojunction (BHJ) solar cells based on organic semiconductors has been widely used to achieve a better match to the solar irradiance spectrum, and power conversion efficiencies beyond 10% have been reported. However, the fill factor of organic solar cells is still limited by the competition between recombination and extraction of free charges. Here, we design advanced material composites leading to a high fill factor of 77% in ternary blends, thus demonstrating how the recombination thresholds can be overcome. Extending beyond the typical sensitization concept, we add a highly ordered polymer that, in addition to enhanced absorption, overcomes limits predicted by classical recombination models. An effective charge transfer from the disordered host system onto the highly ordered sensitizer effectively avoids traps of the host matrix and features an almost ideal recombination behaviour.
New dual-curvature microlens array with a high fill-factor for organic light emitting diode modules
NASA Astrophysics Data System (ADS)
Lin, Tsung-Hung; Yang, Hsiharng; Chao, Ching-Kong; Shui, Hung-Chi
2013-09-01
A new method for fabricating a novel dual-curvature microlens array with a high fill-factor using proximity printing in a lithography process is reported. The lens shapes include dual-curvature, which is a novel shape composed of triangles and hexagons. We utilized UV proximity printing by controlling a printing gap between the mask and substrate. The designed high density microlens array pattern can fabricate a dual-curvature microlens array with a high fill-factor in a photoresist material. It is due to the UV light diffraction which deflects away from the aperture edges and produces a certain exposure in the photoresist material outside the aperture edges. A dual-curvature microlens array with a height ratio of 0.48 can boost axial luminance up to 22%. Therefore, the novel dual-curvature microlens array offers an economical solution for increasing the luminance of organic light emitting diodes.
NASA Technical Reports Server (NTRS)
Brosius, Jeffrey W. (Principal Investigator)
1996-01-01
The plasma properties and magnetic field structure of the solar corona were determined using coordinated observations obtained with NASA/GSFC's Solar EUV Rocket Telescope and Spectrograph (SERTS), the Very Large Array (VLA), and Kitt Peak photospheric longitudinal magnetograms. A problem was identified with the SERTS calibration as determined from laboratory measurements. A revised calibration curve was derived by requiring that the numerous available measured line intensity ratios agreed with their respective theoretical values. Densities were derived from line intensity ratios, and active region densities were found to typically exceed quiet Sun densities by factors of only about 2. The active region density was found to remain constant across the SERTS slit, despite the fact that the emission line intensities vary significantly. This indicates that the product of the path length and the volume filling factor must vary significantly from the active region outskirts to the central core. Filling factors were derived and found to range from much less than one to nearly unity. Wavelength shifts were examined along the SERTS slit in the spatially resolved spectra, but no evidence was found for significant Doppler shifts in active region 7563 or in the quiet Sun. The numerical procedure developed by Monsignori-Fossi and Landini was used to derive the active region and quiet sun differential emission measure (DEM) from the spatially averaged spectra. A DEM was estimated for each spatial pixel in the two dimensional active region images by scaling the averaged active region DEM based upon corresponding pixel intensities of SERTS Mg IX, Fe XV, and Fe XVI images. These results, along with density measurements, were used in an IDL computer code which calculated the temperature dependence of the coronal magnetic field in each spatial pixel by minimizing the difference between the observed and calculated 20 and 6 cm microwave brightness temperatures.
Drainage of the maxillary sinus: a comparative anatomy study in humans and goats.
Ford, Rebecca L; Barsam, Alon; Velusami, Prabhu; Ellis, Harold
2011-02-01
The maxillary sinuses are the most frequently infected paranasal sinuses in humans. It has been suggested that infection occurs relatively commonly in the maxillary sinuses owing to the position of their ostia high on their superomedial walls, which may be suboptimal for natural drainage. This may represent evolutionary lag, whereby the ostia remained in a quadrupedal position as bipedal humans evolved from their primate ancestors. This study examined the hypothesis that drainage of the maxillary sinus is optimal in the quadrupedal position. The drainage of the human maxillary sinus and an analogous quadruped, the goat, was examined and compared in the upright, quadrupedal, and intermediate positions. Department of Anatomy, King's College London. Cadaveric human and goat maxillary sinuses were filled with saline in each position and the volume at which saline overflowed through the ostia was noted. Volume at which spontaneous drainage occurred through ostia. The volume of saline instilled before drainage was maximal in the upright position and reduced with each increase in anterior tilt, with drainage occurring most easily at 90° for both human and goat sinuses. Drainage was significantly better in the quadrupedal head position than upright in both species (p < .01). This study demonstrated that human maxillary sinuses exhibit better passive drainage through their ostia when tilted anteriorly to mimic a quadrupedal head position. This may be an example of an evolutionary lag phenomenon and could be one etiologic factor in the prevalence of maxillary sinusitis in humans.
Atomistic modeling of structure II gas hydrate mechanics: Compressibility and equations of state
NASA Astrophysics Data System (ADS)
Vlasic, Thomas M.; Servio, Phillip; Rey, Alejandro D.
2016-08-01
This work uses density functional theory (DFT) to investigate the poorly characterized structure II gas hydrates, for various guests (empty, propane, butane, ethane-methane, propane-methane), at the atomistic scale to determine key structure and mechanical properties such as equilibrium lattice volume and bulk modulus. Several equations of state (EOS) for solids (Murnaghan, Birch-Murnaghan, Vinet, Liu) were fitted to energy-volume curves resulting from structure optimization simulations. These EOS, which can be used to characterize the compressional behaviour of gas hydrates, were evaluated in terms of their robustness. The three-parameter Vinet EOS was found to perform just as well if not better than the four-parameter Liu EOS, over the pressure range in this study. As expected, the Murnaghan EOS proved to be the least robust. Furthermore, the equilibrium lattice volumes were found to increase with guest size, with double-guest hydrates showing a larger increase than single-guest hydrates, which has significant implications for the widely used van der Waals and Platteeuw thermodynamic model for gas hydrates. Also, hydrogen bonds prove to be the most likely factor contributing to the resistance of gas hydrates to compression; bulk modulus was found to increase linearly with hydrogen bond density, resulting in a relationship that could be used predictively to determine the bulk modulus of various structure II gas hydrates. Taken together, these results fill a long existing gap in the material chemical physics of these important clathrates.
Atomistic modeling of structure II gas hydrate mechanics: Compressibility and equations of state
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vlasic, Thomas M.; Servio, Phillip; Rey, Alejandro D., E-mail: alejandro.rey@mcgill.ca
2016-08-15
This work uses density functional theory (DFT) to investigate the poorly characterized structure II gas hydrates, for various guests (empty, propane, butane, ethane-methane, propane-methane), at the atomistic scale to determine key structure and mechanical properties such as equilibrium lattice volume and bulk modulus. Several equations of state (EOS) for solids (Murnaghan, Birch-Murnaghan, Vinet, Liu) were fitted to energy-volume curves resulting from structure optimization simulations. These EOS, which can be used to characterize the compressional behaviour of gas hydrates, were evaluated in terms of their robustness. The three-parameter Vinet EOS was found to perform just as well if not better thanmore » the four-parameter Liu EOS, over the pressure range in this study. As expected, the Murnaghan EOS proved to be the least robust. Furthermore, the equilibrium lattice volumes were found to increase with guest size, with double-guest hydrates showing a larger increase than single-guest hydrates, which has significant implications for the widely used van der Waals and Platteeuw thermodynamic model for gas hydrates. Also, hydrogen bonds prove to be the most likely factor contributing to the resistance of gas hydrates to compression; bulk modulus was found to increase linearly with hydrogen bond density, resulting in a relationship that could be used predictively to determine the bulk modulus of various structure II gas hydrates. Taken together, these results fill a long existing gap in the material chemical physics of these important clathrates.« less
Cardiovascular adaptations supporting human exercise-heat acclimation.
Périard, Julien D; Travers, Gavin J S; Racinais, Sébastien; Sawka, Michael N
2016-04-01
This review examines the cardiovascular adaptations along with total body water and plasma volume adjustments that occur in parallel with improved heat loss responses during exercise-heat acclimation. The cardiovascular system is well recognized as an important contributor to exercise-heat acclimation that acts to minimize physiological strain, reduce the risk of serious heat illness and better sustain exercise capacity. The upright posture adopted by humans during most physical activities and the large skin surface area contribute to the circulatory and blood pressure regulation challenge of simultaneously supporting skeletal muscle blood flow and dissipating heat via increased skin blood flow and sweat secretion during exercise-heat stress. Although it was traditionally held that cardiac output increased during exercise-heat stress to primarily support elevated skin blood flow requirements, recent evidence suggests that temperature-sensitive mechanisms may also mediate an elevation in skeletal muscle blood flow. The cardiovascular adaptations supporting this challenge include an increase in total body water, plasma volume expansion, better sustainment and/or elevation of stroke volume, reduction in heart rate, improvement in ventricular filling and myocardial efficiency, and enhanced skin blood flow and sweating responses. The magnitude of these adaptations is variable and dependent on several factors such as exercise intensity, duration of exposure, frequency and total number of exposures, as well as the environmental conditions (i.e. dry or humid heat) in which acclimation occurs. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Different types of implants for reconstructive breast surgery.
Rocco, Nicola; Rispoli, Corrado; Moja, Lorenzo; Amato, Bruno; Iannone, Loredana; Testa, Serena; Spano, Andrea; Catanuto, Giuseppe; Accurso, Antonello; Nava, Maurizio B
2016-05-16
Breast cancer is the most common cancer in women worldwide, and is a leading cause of cancer death among women. Prophylactic or curative mastectomy is often followed by breast reconstruction for which there are several surgical approaches that use breast implants with which surgeons can restore the natural feel, size and shape of the breast. To assess the effects of different types of breast implants on capsular contracture, surgical short- and long-term complications, postoperative satisfaction level and quality of life in women who have undergone reconstructive breast surgery after mastectomy. We searched the Cochrane Breast Cancer Group's Specialised Register on 20 July 2015, MEDLINE (1985 to 20 July 2015), EMBASE (1985 to 20 July 2015) and the Cochrane Central Register of Controlled Trials (CENTRAL; Issue 8, 2015). We also searched the World Health Organization's International Clinical Trials Registry Platform (WHO ICTRP) and ClinicalTrials.gov on 16 July 2015. We included randomised controlled trials (RCTs) and quasi-RCTs that compared different types of breast implants for reconstructive surgery. We considered the following types of intervention: implant envelope surfaces - texturised versus smooth; implant filler material - silicone versus saline, PVP-Hydrogel versus saline; implant shape - anatomical versus round; implant volume - variable versus fixed; brands - different implant manufacturing companies and implant generation (fifth versus previous generations). Two review authors independently assessed methodological quality and extracted data. We used standard Cochrane methodological procedures. The quality of the evidence was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system. Five RCTs with 202 participants met the inclusion criteria. The women participants were typically in their 50s, and the majority of them (about 82%) received reconstructive surgery following breast cancer, while the others had reconstructive surgery after prophylactic mastectomy. The studies were heterogenous in terms of implant comparisons, which prevented us from pooling the data.The studies were judged as being at an unclear risk of bias for most risk of bias items owing to poor quality of reporting in the trial publications. Three of the five RCTs were judged to be at high risk of attrition bias, and one at high risk of detection bias.Textured silicone versus smooth silicone implants: textured implants were associated with worse outcomes when compared to smooth implants (capsular contracture: risk ratio (RR) 0.82, 95% CI 0.14 to 4.71; 1 study, 20 participants; very low quality evidence; reintervention: RR 0.82, 95% CI 0.14 to 4.71; 1 study, 20 participants; very low quality evidence). No results in this comparison were statistically significant.Silicone versus saline implants: saline-filled implants performed better than silicone-filled implants for some outcomes; specifically, they produced less severe capsular contracture (RR 3.25, 95% CI 1.24 to 8.51; 1 study, 60 participants; very low quality evidence) and increased patient satisfaction (RR 0.60, 95% CI 0.41 to 0.88; 1 study, 58 participants; very low quality evidence). However reintervention was significantly more frequent in the saline-filled implant group than in the silicone-filled group (OR 0.08, 95% CI 0.01 to 0.43; 1 study, 60 participants; very low quality evidence).Poly(N-vinyl-2-pyrrolidone) hydrogel-filled (PVP-hydrogel) versus saline-filled implants: PVP-hydrogel-filled implants were associated with worse outcomes when compared to saline-filled implants (capsular contracture: RR 3.50, 95% CI 0.83 to 14.83; 1 study, 40 participants; very low quality evidence; short-term complications: RR 2.10, 95% CI 0.21 to 21.39; 1 study, 41 participants; very low quality evidence).Anatomical versus round implants: anatomical implants were associated with worse outcomes than round implants (capsular contracture: RR 2.00, 95% CI 0.20 to 20.15; 1 study, 36 participants; very low quality evidence; short-term complications: RR 2.00, 95% CI 0.42 to 9.58; 1 study, 36 participants; very low quality evidence; reintervention: RR 1.50, 95% CI 0.51 to 4.43; 1 study, 36 participants; very low quality evidence). No results in this comparison were statistically significant.Variable-volume versus fixed-volume implants: data about one-stage reconstruction using variable-volume implants were compared with data about fixed-volume implants positioned during the second surgical procedure of two-stage reconstructions. Fixed-volume implant reconstructions were possibly associated with a greater number of women reporting that their reconstruction corresponded with expected results (RR 0.25, 95% CI 0.10 to 0.62; 1 study, 40 participants; very low quality evidence) and fewer reinterventions (RR 7.00, 95% CI 1.82 to 26.89; 1 study, 40 participants; very low quality evidence) when compared to variable-volume implants. A higher patient satisfaction level (rated from 1 to 6, with 1 being very bad and 6 being very good) was found with the fixed-volume implants for overall aesthetic result (mean difference (MD) -1.10, 95% CI -1.59 to -0.61; 1 study, 40 participants; very low quality evidence).There were no studies that examined the effects of recent (fifth) generation silicone implants versus previous generations or different implant manufacturing companies. Despite the central role of breast reconstruction in women with breast cancer, the best implants to use in reconstructive surgery have been studied rarely in the context of RCTs. Furthermore the quality of these studies and the overall evidence they provide is largely unsatisfactory. Some of our results can be interpreted as early evidence of potentially large differences between different surgical approaches, which should be confirmed in new high-quality RCTs that include a larger number of women. These days - even after a few million women have had breasts reconstructed - surgeons cannot inform women about the risks and complications of different implant-based breast reconstructive options on the basis of results derived from RCTs.
Differential effects of lower body negative pressure and upright tilt on splanchnic blood volume
Taneja, Indu; Moran, Christopher; Medow, Marvin S.; Glover, June L.; Montgomery, Leslie D.; Stewart, Julian M.
2015-01-01
Upright posture and lower body negative pressure (LBNP) both induce reductions in central blood volume. However, regional circulatory responses to postural changes and LBNP may differ. Therefore, we studied regional blood flow and blood volume changes in 10 healthy subjects undergoing graded lower-body negative pressure (−10 to −50 mmHg) and 8 subjects undergoing incremental head-up tilt (HUT; 20°, 40°, and 70°) on separate days. We continuously measured blood pressure (BP), heart rate, and regional blood volumes and blood flows in the thoracic, splanchnic, pelvic, and leg segments by impedance plethysmography and calculated regional arterial resistances. Neither LBNP nor HUT altered systolic BP, whereas pulse pressure decreased significantly. Blood flow decreased in all segments, whereas peripheral resistances uniformly and significantly increased with both HUT and LBNP. Thoracic volume decreased while pelvic and leg volumes increased with HUT and LBNP. However, splanchnic volume changes were directionally opposite with stepwise decreases in splanchnic volume with LBNP and stepwise increases in splanchnic volume during HUT. Splanchnic emptying in LBNP models regional vascular changes during hemorrhage. Splanchnic filling may limit the ability of the splanchnic bed to respond to thoracic hypovolemia during upright posture. PMID:17085534
Gehrich, Alan Paul; Hill, Micah J; McWilliams, Grant D E; Larsen, Wilma; McCartin, Tamarin
2012-01-01
Urodynamic studies, routinely performed in women with lower urinary tract symptoms, have a large impact on clinical decision making. Unfortunately, these studies are insensitive in reproducing idiopathic detrusor overactivity (IDO). We set out to examine whether serial cystometry with different distending fluid temperatures could better reproduce symptoms. Eighty-six women were enrolled in a double-blinded, randomized, crossover study. Two cystometries were performed in series, starting with either body temperature fluid (BTF) or room temperature fluid (RTF) and then repeating cystometry with the other temperature fluid. Primary outcomes included first sensation, first urge, and maximum cystometric capacity. Secondary outcomes included subjective sensation of bladder discomfort and the incidence of IDO. In aggregate, the temperature of the fluid did not affect volumes of bladder sensation. There were no differences in self-reported bladder irritation or IDO between the different temperature fluids. There was a significant carryover effect with BTF. BTF administered first reached sensory thresholds at lower volumes than when it was administered second after RTF. Room temperature fluid cystometry showed no statistical difference in volume between first fill and second fill. Idiopathic detrusor overactivity contractions were seen in 9% of studies and were not affected by period or temperature. These data suggest that BTF and RTF independently do not affect bladder sensory thresholds. The periodicity in combination with varying fluid temperature is of greater impact. This study documents that changes in temperature of the distending fluid from BTF to RTF or vice versa likely do not provoke IDO contractions.
NASA Astrophysics Data System (ADS)
Subasic, E.; Huang, C.; Jakumeit, J.; Hediger, F.
2015-06-01
The ongoing increase in the size and capacity of state-of-the-art wind power plants is highlighting the need to reduce the weight of critical components, such as hubs, main shaft bearing housings, gear box housings and support bases. These components are manufactured as nodular iron castings (spheroid graphite iron, or SGI). A weight reduction of up to 20% is achievable by optimizing the geometry to minimize volume, thus enabling significant downsizing of wind power plants. One method for enhancing quality control in the production of thick-walled SGI castings, and thus reducing tolerances and, consequently, enabling castings of smaller volume is via a casting simulation of mould filling and solidification based on a combination of microscopic model and VoF-multiphase approach. Coupled fluid flow with heat transport and phase transformation kinetics during solidification is described by partial differential equations and solved using the finite volume method. The flow of multiple phases is described using a volume of fluid approach. Mass conservation equations are solved separately for both liquid and solid phases. At the micro-level, the diffusion-controlled growth model for grey iron eutectic grains by Wetterfall et al. is combined with a growth model for white iron eutectic grains. The micro-solidification model is coupled with macro-transport equations via source terms in the energy and continuity equations. As a first step the methodology was applied to a simple geometry to investigate the impact of mould-filling on the grey-to-white transition prediction in nodular cast iron.
Utopia and Hellas basins, Mars: Twins separated at birth
NASA Astrophysics Data System (ADS)
Searls, Mindi L.; Banerdt, W. Bruce; Phillips, Roger J.
2006-08-01
Using topography and gravity data as constraints, we formulate spherical harmonic thin elastic-shell models to determine the subsurface structure of the Hellas and Utopia basins. For Hellas, we show that our model is consistent with the elastic thickness results of McGovern et al. (2002, 2004). The thin elastic lithosphere at the time of formation implies that Hellas is close to isostatic. Since Utopia formed earlier, we argue that an isostatic assumption is justified for the Utopia basin before it was filled. From this supposition, we derive a system of equations that allows us to solve for the amount of fill, the prefill topography, and the amount of flexure due to the fill within the Utopia basin. An analysis of the parameter space shows that the fill density and the amount of fill is strongly dependent on the elastic thickness at the time of infilling. A thinner elastic lithosphere favors a denser fill, while a thicker lithosphere will allow for less dense material. Likewise, larger crustal thickness values lead to smaller fill density values. The presence of quasi-circular depressions, interpreted as impact craters, within the Utopia basin indicates that the majority of the material within Utopia was deposited prior to 4.04-4.11 Ga. The early timing for the deposition combined with the heat imparted by the basin forming event argues for a thinner lithosphere which could, in turn, suggest fill densities that are more consistent with a volcanic load than with pure sediment or ice-rich material. These results are supported using an alternative method of determining the amount of fill and flexure within Utopia. This model assumes that Hellas and Utopia were initially identical and that the only difference in their subsequent evolution was the addition of material in the Utopia basin. The volume of material needed to fill Utopia is immense (on the order of 50 million km3 or more). The high density obtained for the fill requires that it contain a large igneous component, the source of which is problematic. Relaxing the isostatic assumption to a reasonable degree perturbs the density bound only slightly.
An inexpensive and portable microvolumeter for rapid evaluation of biological samples.
Douglass, John K; Wcislo, William T
2010-08-01
We describe an improved microvolumeter (MVM) for rapidly measuring volumes of small biological samples, including live zooplankton, embryos, and small animals and organs. Portability and low cost make this instrument suitable for widespread use, including at remote field sites. Beginning with Archimedes' principle, which states that immersing an arbitrarily shaped sample in a fluid-filled container displaces an equivalent volume, we identified procedures that maximize measurement accuracy and repeatability across a broad range of absolute volumes. Crucial steps include matching the overall configuration to the size of the sample, using reflected light to monitor fluid levels precisely, and accounting for evaporation during measurements. The resulting precision is at least 100 times higher than in previous displacement-based methods. Volumes are obtained much faster than by traditional histological or confocal methods and without shrinkage artifacts due to fixation or dehydration. Calibrations using volume standards confirmed accurate measurements of volumes as small as 0.06 microL. We validated the feasibility of evaluating soft-tissue samples by comparing volumes of freshly dissected ant brains measured with the MVM and by confocal reconstruction.
Effects of nifedipine and captopril on vascular capacitance of ganglion-blocked anesthetized dogs.
Ogilvie, R I; Zborowska-Sluis, D
1990-03-01
The hemodynamic effects of nifedipine and captopril at doses producing similar reductions in arterial pressure were studied in pentobarbital-anesthetized ventilated dogs after splenectomy during ganglion blockade with hexamethonium. Mean circulatory filling pressure (Pmcf) was determined during transient circulatory arrest induced by acetylcholine at baseline circulating blood volumes and after increases of 5 and 10 mL/kg. Central blood volumes (pulmonary artery to aortic root) were determined from transit times, and separately determined cardiac outputs (right atrium to pulmonary artery) were estimated by thermodilution. Nifedipine (n = 5) increased Pmcf at all circulating blood volumes and reduced total vascular capacitance without a change in total vascular compliance. Central blood volume, right atrial pressure, and cardiac output were increased with induced increases in circulating blood volume. In contrast, captopril (n = 5) did not alter total vascular capacitance, central blood volume, right atrial pressure, or cardiac output at baseline or with increased circulating volume. Thus, at doses producing similar reductions in arterial pressure, nifedipine but not captopril increased venous return and cardiac output in ganglion-blocked dogs.
33 CFR 159.107 - Rolling test.
Code of Federal Regulations, 2010 CFR
2010-07-01
... liquid retention components, if any, filled with water to half of their volume, must be subjected to 100 cycles with the axis of rotation 4 feet from the centerline of the device, no more than 6 inches below... rotated 90 degrees on its vertical axis and subjected to another 100 cycles. This testing must be repeated...
33 CFR 159.107 - Rolling test.
Code of Federal Regulations, 2014 CFR
2014-07-01
... liquid retention components, if any, filled with water to half of their volume, must be subjected to 100 cycles with the axis of rotation 4 feet from the centerline of the device, no more than 6 inches below... rotated 90 degrees on its vertical axis and subjected to another 100 cycles. This testing must be repeated...
33 CFR 159.107 - Rolling test.
Code of Federal Regulations, 2012 CFR
2012-07-01
... liquid retention components, if any, filled with water to half of their volume, must be subjected to 100 cycles with the axis of rotation 4 feet from the centerline of the device, no more than 6 inches below... rotated 90 degrees on its vertical axis and subjected to another 100 cycles. This testing must be repeated...
33 CFR 159.107 - Rolling test.
Code of Federal Regulations, 2013 CFR
2013-07-01
... liquid retention components, if any, filled with water to half of their volume, must be subjected to 100 cycles with the axis of rotation 4 feet from the centerline of the device, no more than 6 inches below... rotated 90 degrees on its vertical axis and subjected to another 100 cycles. This testing must be repeated...
Remedial Investigation Report, Presidio Main Installation, Presidio of San Francisco. Volume 1: Text
1997-01-01
located in the southwestern portion of the PSF, was reportedly a low area which was filled and graded to create a flat surface for a soccer field...1991). Calcium is a macronutrient and is considered nontoxic unless present within a receptors diet at extremely high levels (Bodek et al., 1988
Commander Lousma is surrounded by a week's worth of trash on the middeck
1982-03-30
STS003-25-231 (22-30 March 1982) --- Astronaut Jack R. Lousma, STS-3 commander, wearing communication kit assembly mini headset, gathers three freefloating plastic trash bags filled with empty containers, paper towels, straws, etc. Lousma will stow them in a designated stowage volume. Photo credit: NASA
Moliavchikova, O V; Cherevashchenko, L A; Grinzaĭd, Iu M; Aĭvazov, V N; Zhuravlev, M E
2007-01-01
The authors propose combined therapy improving cerebral circulation in patients in an intermediate period of a mild craniocerebral trauma. The combination consists of radon baths and transcranial magnetotherapy which raise blood volume filling, relieve vascular resistance, improve venous outflow.
Investigation of Flow in a Centrifugal Pump
NASA Technical Reports Server (NTRS)
Fischer, Karl
1946-01-01
The investigation of the flow in a centrifugal pump indicated that the flow patterns in frictional fluid are fundamentally different from those in frictionless fluid. In particular, the dead air space adhering to the section side undoubtedly causes a reduction of the theoretically possible delivery head. The velocity distribution over a parallel circle is also subjected to a noticeable change as a result of the incomplete filling of the passages. The relative velocity on the pressure side of the vane, which for passages completely filled with active flow would differ little from zero even at comparatively lower than normal delivery volume, is increased, so that no rapid reverse flow occurs on the pressure side of the vane even for smaller delivery volume. It was established, further, that the flow ceases to be stationary for very small quantities of water. The inflow to the impeller can be regarded as radial for the operating range an question. The velocity triangles at the exit are subjected to a significant alteration in shape ae a result of the increased peripheral velocity, which may be of particular importance in the determination of the guide vane entrance angle.
Gripping characteristics of an electromagnetically activated magnetorheological fluid-based gripper
NASA Astrophysics Data System (ADS)
Choi, Young T.; Hartzell, Christine M.; Leps, Thomas; Wereley, Norman M.
2018-05-01
The design and test of a magnetorheological fluid (MRF)-based universal gripper (MR gripper) are presented in this study. The MR gripper was developed to have a simple design, but with the ability to produce reliable gripping and handling of a wide range of simple objects. The MR gripper design consists of a bladder mounted atop an electromagnet, where the bladder is filled with an MRF, which was formulated to have long-term stable sedimentation stability, that was synthesized using a high viscosity linear polysiloxane (HVLP) carrier fluid with a carbonyl iron particle (CIP) volume fraction of 35%. Two bladders were fabricated: a magnetizable bladder using a magnetorheological elastomer (MRE), and a passive (non-magnetizable) silicone rubber bladder. The holding force and applied (initial compression) force of the MR gripper for a bladder fill volume of 75% were experimentally measured, for both magnetizable and passive bladders, using a servohydraulic material testing machine for a range of objects. The gripping performance of the MR gripper using an MRE bladder was compared to that of the MR gripper using a passive bladder.
2001-10-25
questionnaire was filled out before test which is very important criteria for each subject for investigating are smoking cigarettes, having asthma, chronic...9, 12]. Secondly, observed FVC and FEV1 data plotted are taken under investigation. According to the questionnaire filled out, subjects... questionnaire filled in by each subject on the result of the diagnosing (categorizing FVC graphs) COPD, elimination of erroneous factors affecting
Training the Trainers: Mission Analysis and Support for USAR Training Divisions
1991-03-25
the Department of Defense (DOD),! mobilization expansion is a key factor In Limited Mobilization9 or Graduated Military Responseio theories of...less filled units of their personnel to fill earlier deploying units. After stripping units at random with 19 disastrous morale results it was decided...28 assigned) once all companies In the division are filled. This mission is identified in the unit’s Table of Distribution and Allowance ( TDA ) and
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, JY; Hong, DL
Purpose: To investigate the impact of bladder filling status of the organs at risk (OARs) on dose distribution during intensity modulated radiotherapy (IMRT) for cervical cancer patients. Methods: Twelve cervical cancer patients treated with IMRT were selected for this study. The prescription dose was 45Gy/25 fractions with the 6 MV photon beam. All patients performed two CT scans, one with an empty bladder, the other one with bladder filled. For the registration of two CT scans, the fusion was automatically carried out upon the bony anatomy. The OARs (bladder, rectum, pelvic bone and small intestine) were delineated to planning CTmore » to evaluate the dose distributions. These dose distributions were compared between empty bladder and bladder filling. Results: The bladder volume with empty bladder and bladder filling was 403.2±124.13cc and 101.4±87.5cc, respectively. There were no statistical differences between empty bladder and bladder filling in the mean value of pelvic bone V10Gy, V20Gy, V40Gy; rectum V40Gy and V45Gy. The bladder V40Gy and V45Gy were lower in the bladder filling group than in the empty bladder group (63.7%±5.8% vs 87.5%±7.8%, 45.1%±9.5% vs 62.4%±11.8%, respectively). The V45Gy for small intestine in the bladder filling group was significantly less than the empty bladder group (146.7cc±95.3cc vs 245.7cc±101.8cc). Conclusion: Our study finds that the bladder filling status did not have a significant impact on dose distribution in the rectum and pelvic bone. However, the changes of bladder filling have a large impact on bladder and small intestine doses. A full bladder is strongly recommended during treatment for cervical cancer patients.« less
NASA Astrophysics Data System (ADS)
Sanwani, Edy; Ikhwanto, Muhammad
2017-01-01
The objective of this paper is to investigate the effect of ball filling and ratio of feed to grinding balls on the kinetic of grinding of ferronickel slag in a laboratory scale ball mill. The experiments were started by crushing the ferronickel slag samples using a roll crusher to produce -3 mesh (-6.7 mm) product. This product, after sampling and sample dividing processes, was then used as feed for grinding process. The grinding was performed with variations of ball filling and ratio of feed to grinding balls for 150 minutes. At every certain time interval, particle size analysis was carried out on the grinding product. The results of the experiments were also used to develop linear regression model of the effect of grinding variables on the P80 of the product. Based on this study, it was shown that P80 values of the grinding products declined sharply until 70 minutes of grinding time due to the dominant mechanism of impact breakage and then decreased slowly after 70 minutes until 150 minutes of grinding time due to dominant mechanism of attrition breakage. Kinetics study of the grinding process on variations of grinding ball filling showed that the optimum rate of formation of fine particles for 20%, 30%, 40% and 50% mill volume was achieved at a particle size of 400 µm in which the best initial rate of formation occurred at 50% volume of mill. At the variations of ratio of feed to grinding balls it was shown that the optimum rate of grinding for the ratio of 1:10, 1: 8 and 1: 6 was achieved at a particle size of 400 µm and for the ratio of 1: 4 was at 841 µm in which the best initial rate of formation occurred at a 1:10 ratio. In this study, it was also produced two regression models that can predict the P80 value of the grinding product as a function of the variables of grinding time, ball filling and the ratio of the feed to grinding balls.
Intermittent surface water connectivity: Fill and spill vs. fill and merge dynamics
Leibowitz, Scott G.; Mushet, David M.; Newton, Wesley E.
2016-01-01
Intermittent surface connectivity can influence aquatic systems, since chemical and biotic movements are often associated with water flow. Although often referred to as fill and spill, wetlands also fill and merge. We examined the effects of these connection types on water levels, ion concentrations, and biotic communities of eight prairie pothole wetlands between 1979 and 2015. Fill and spill caused pulsed surface water connections that were limited to periods following spring snow melt. In contrast, two wetlands connected through fill and merge experienced a nearly continuous, 20-year surface water connection and had completely coincident water levels. Fill and spill led to minimal convergence in dissolved ions and macroinvertebrate composition, while these constituents converged under fill and merge. The primary factor determining differences in response was duration of the surface water connection between wetland pairs. Our findings suggest that investigations into the effects of intermittent surface water connections should not consider these connections generically, but need to address the specific types of connections. In particular, fill and spill promotes external water exports while fill and merge favors internal storage. The behaviors of such intermittent connections will likely be accentuated under a future with more frequent and severe climate extremes.
Propionyl-L-carnitine limits chronic ventricular dilation after myocardial infarction in rats.
Micheletti, R; Di Paola, E D; Schiavone, A; English, E; Benatti, P; Capasso, J M; Anversa, P; Bianchi, G
1993-04-01
To determine whether propionyl-L-carnitine (PLC) administration ameliorates ventricular remodeling after myocardial infarction, we performed coronary occlusion in rats and examined the long-term effects of the drug 19-24 wk after surgery. In view of the well-established role of angiotensin-converting enzyme (ACE) inhibitors in the reduction of ventricular dilation after infarction, the therapeutic impact of oral PLC (60 mg/kg) was compared with that of enalapril (1 mg/kg). Infarct size measured planimetrically was found to be comparable in untreated, PLC-treated, and enalapril-treated rats, averaging 40-46% of the left ventricular free wall. Heart weight was increased 14, 16, and 11% with no treatment, with PLC, and with enalapril, respectively. The relationship between left ventricular filling pressure and chamber volume demonstrated that PLC and enalapril significantly prevented the expansion in cavitary size after infarction. These protective influences were observed throughout the range of filling pressures measured, from 0 to 30 mmHg. At a uniform reference point of filling pressure of 4 mmHg, untreated infarcted hearts showed an expansion in ventricular volume of 2.17-fold (P < 0.0001). Corresponding increases in this parameter after PLC and enalapril were 36 and 43%, respectively, both not statistically significant. Moreover, PLC was capable of reducing the alterations in myocardial compliance associated with myocardial infarction. In conclusion, PLC reduces the magnitude of decompensated eccentric hypertrophy produced by myocardial infarction in a manner similar to that found with ACE inhibition.
Dynamic mechanical analysis of waste tyre rubber filled brake friction composite materials
NASA Astrophysics Data System (ADS)
Rathi, Mukesh Kumar; Singh, Tej; Chauhan, Ranchan
2018-05-01
In this research work, the dynamic mechanical properties of waste tyre rubber filled friction composites were studied. Four friction composites with varying amount of waste rubber (0, 4, 8, 12 wt.%) and barium sulphate (38, 42, 46, 50 wt.%) were designed and fabricated as per industrial norms. Dynamic mechanical analysis has been carried out to characterize the storage modulus, loss modulus and damping factor of the fabricated friction composite. Experimental results indicated that storage modulus decreases with increasing waste rubber content up to particular loading (4 wt.%), and after that it increases with further loading. The loss modulus of the composites increases steadily with increasing waste rubber content whereas, damping factor remain maximum for 12 wt.% waste rubber filled friction composites.
Grembowski, D; Fiset, L; Milgrom, P; Forrester, K; Spadafora, A
1997-01-01
An epidemiology analysis was performed to identify patient and dentist factors influencing over- and undertreatment of restorative services in a sample of insured adults. At baseline, 681 Washington State employees and their spouses, aged 20 to 34 years and residing in the Olympia or Pullman areas, were interviewed by telephone. Oral assessments were conducted to measure personal characteristics, oral disease, and restoration quality. Adults were followed for two years to measure use of restorative services from dental insurance claims. Each adult's baseline and claims data were linked with provider and practice variables collected from the dentist who provided treatment. For overtreatment, 39 percent of adults received one or more replacement restorations in nondecayed teeth with satisfactory fillings at baseline, while 18 percent of adults had one or more restorations placed in teeth with no decay and fillings. An adult's probability of overtreatment was higher if the adult had more fillings at baseline, or if an adult's dentist was younger, had a busy practice, advertised, charged higher fees, had less continuing education, or had a solo practice. For undertreatment, about 16 percent of adults either received no replacement restorations in teeth with unsatisfactory fillings at baseline, or had decayed teeth at baseline that were not filled or crowned. An adult's probability of undertreatment was higher if an adult had less decayed or more missing surfaces at baseline, or if an adult's dentist believed in sharing information with patients, had a busy practice, or reported not placing fillings when radiographic evidence of new caries was present. A minority of adults aged 20 to 34 experienced potential over- or undertreatment of restorative services, which are influenced by both patient and dentist factors.
3-D ultrasound volume reconstruction using the direct frame interpolation method.
Scheipers, Ulrich; Koptenko, Sergei; Remlinger, Rachel; Falco, Tony; Lachaine, Martin
2010-11-01
A new method for 3-D ultrasound volume reconstruction using tracked freehand 3-D ultrasound is proposed. The method is based on solving the forward volume reconstruction problem using direct interpolation of high-resolution ultrasound B-mode image frames. A series of ultrasound B-mode image frames (an image series) is acquired using the freehand scanning technique and position sensing via optical tracking equipment. The proposed algorithm creates additional intermediate image frames by directly interpolating between two or more adjacent image frames of the original image series. The target volume is filled using the original frames in combination with the additionally constructed frames. Compared with conventional volume reconstruction methods, no additional filling of empty voxels or holes within the volume is required, because the whole extent of the volume is defined by the arrangement of the original and the additionally constructed B-mode image frames. The proposed direct frame interpolation (DFI) method was tested on two different data sets acquired while scanning the head and neck region of different patients. The first data set consisted of eight B-mode 2-D frame sets acquired under optimal laboratory conditions. The second data set consisted of 73 image series acquired during a clinical study. Sample volumes were reconstructed for all 81 image series using the proposed DFI method with four different interpolation orders, as well as with the pixel nearest-neighbor method using three different interpolation neighborhoods. In addition, volumes based on a reduced number of image frames were reconstructed for comparison of the different methods' accuracy and robustness in reconstructing image data that lies between the original image frames. The DFI method is based on a forward approach making use of a priori information about the position and shape of the B-mode image frames (e.g., masking information) to optimize the reconstruction procedure and to reduce computation times and memory requirements. The method is straightforward, independent of additional input or parameters, and uses the high-resolution B-mode image frames instead of usually lower-resolution voxel information for interpolation. The DFI method can be considered as a valuable alternative to conventional 3-D ultrasound reconstruction methods based on pixel or voxel nearest-neighbor approaches, offering better quality and competitive reconstruction time.
Ke, Weijun; Xiao, Chuanxiao; Wang, Changlei; Saparov, Bayrammurad; Duan, Hsin-Sheng; Zhao, Dewei; Xiao, Zewen; Schulz, Philip; Harvey, Steven P; Liao, Weiqiang; Meng, Weiwei; Yu, Yue; Cimaroli, Alexander J; Jiang, Chun-Sheng; Zhu, Kai; Al-Jassim, Mowafak; Fang, Guojia; Mitzi, David B; Yan, Yanfa
2016-07-01
Lead thiocyanate in the perovskite precursor can increase the grain size of a perovskite thin film and reduce the conductivity of the grain boundaries, leading to perovskite solar cells with reduced hysteresis and enhanced fill factor. A planar perovskite solar cell with grain boundary and interface passivation achieves a steady-state efficiency of 18.42%. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
The catastrophic landfill flowslide at Hongao dumpsite on 20 December 2015 in Shenzhen, China
NASA Astrophysics Data System (ADS)
Xu, Qiang; Peng, Dalei; Li, Weile; Dong, Xiujun; Hu, Wei; Tang, Minggao; Liu, Fangzhou
2017-02-01
A catastrophic flowslide occurred at the Hongao dumpsite on 20 December 2015 in the Guangming New District of Shenzhen, China. The flowslide caused 77 causalities and damaged 33 buildings. In the absence of extreme weather conditions and seismic activity, the causes of the failure were analyzed on the basis of multi-temporal remote-sensing images, site investigation, in situ tests, laboratory tests, and numerical analyses. Site investigations showed that the volume of the displaced material was 2.32 × 106 m3 and the volume of the pre-failure waste filling was 6.27 × 106 m3. The flowslide was characterized by high travel velocity and long runout distance. The displaced material was primarily a mixture of silty soil and construction and demolition waste with water content of 17.3-42.4 %. The primary causes of the failure were concluded to be the following: (1) groundwater flow had stagnated in the dumpsite due to drainage system failure and the underlying impermeable granite stratum; (2) the accumulation rate and total volume of the waste filling was in exceedance of the design capacity. The flowslide may be ascribed to the development of excess pore-water pressure as evidence of liquefaction was observed at several locations, and it is postulated that such phenomena were related to the surcharge loads imposed by the unregulated disposal activities.
1993-03-17
modulator: Number of Elements 16 x 16 Pixel Size 1 mmxl mm Area Fill Factor > 90% Reflectance > 90% Phase Shift 900 Frame Rate > 1 kHz Operational Spectral...electro-optic constants. By using reflected light from the second interface a factor of two increase in phase shift is obtained for an applied voltage vs...wavelengths in general require thinner PLZT wafers. One of the objectives of the SLM design was to maximize pixel area fill factor and thereby the
McKinney, Tim S.; Anning, David W.
2009-01-01
The Southwest Principal Aquifers study area consists of most of California and Nevada and parts of Utah, Arizona, New Mexico, and Colorado; it is about 409,000 square miles. The Basin-fill aquifers extend through about 201,000 square miles of the study area and are the primary source of water for cities and agricultural communities in basins in the arid and semiarid southwestern United States (Southwest). The demand on limited ground-water resources in areas in the southwestern United States has increased significantly. This increased demand underscores the importance of understanding factors that affect the water quality in basin-fill aquifers in the region, which are being studied through the U.S. Geological Survey's National Water-Quality Assessment (NAWQA) program. As a part of this study, spatial datasets of natural and anthropogenic factors that may affect ground-water quality of the basin-fill aquifers in the southwestern United States were developed. These data include physical characteristics of the region, such as geology, elevation, and precipitation, as well as anthropogenic factors, including population, land use, and water use. Spatial statistics for the alluvial basins in the Southwest have been calculated using the datasets. This information provides a foundation for the development of conceptual and statistical models that relate natural and anthropogenic factors to ground-water quality across the Southwest. A geographic information system (GIS) was used to determine and illustrate the spatial distribution of these basin-fill variables across the region. One hundred-meter resolution raster data layers that represent the spatial characteristics of the basins' boundaries, drainage areas, population densities, land use, and water use were developed for the entire Southwest.
Effective g-factors of carriers in inverted InAs/GaSb bilayers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mu, Xiaoyang; Collaborative Innovation Center of Quantum Matter, Beijing 100871; Sullivan, Gerard
2016-01-04
We perform tilt-field transport experiment on inverted InAs/GaSb, which hosts quantum spin Hall insulator. By means of coincidence method, Landau level (LL) spectra of electron and hole carriers are systematically studied at different carrier densities tuned by gate voltages. When Fermi level stays in the conduction band, we observe LL crossing and anti-crossing behaviors at odd and even filling factors, respectively, with a corresponding g-factor of 11.5. It remains nearly constant for varying filling factors and electron densities. On the contrary, for GaSb holes, only a small Zeeman splitting is observed even at large tilt angles, indicating a g-factor ofmore » less than 3.« less
Utilisation des technologies d'impression pour le remplissage industriel des trous d'interconnexion
NASA Astrophysics Data System (ADS)
Blonde, Paul
This master project concerns a feasibility study about the use of inkjet drop-on-demand to fill through silicon vias in MEMS "via last" microfabrication process. The aim of our research was to develop a comprehensive process based on the use of a dispersion of a gold/tin alloy (Au80Sn 20) of nanoparticles in suspension in a carrier fluid. Our work mainly focused on the preparation of stable suspensions of nanoparticles and on the high precision filling of the vias. We first developed a method to form a stable suspension of nanoparticles in a carrier fluid using a surfactant, polyvinylpyrrolidone (PVP). Tests performed on various solvents allowed us to determine that isopropanol was the best carrier fluid to achieve high volume fractions of suspended nanoparticles. The volume fraction of the stable dispersion with the highest content reached 11 %. The conditions to generate stable individual microdroplets from a piezoelectric printing actuator were then analyzed. The generation of monodisperse microdroplets beiing a complex process, partly described by Fromm's theory and the theory of waveguides, we investigated the operating conditions permitting to precisely set the drop volume and ejection velocity. We therefore characterized an "ejectability zone" model universally usable to generate microdrops with desired output parameters based on the amplitude, width, and frequency of the electric pulse applied to the piezoelectric actuator of a print head having a 50 mum diameter aperture. We also developed a theoretical kinematical model describing the trajectories of microdrops during printing in order to understand the influence of their volume and initial velocity on the accuracy, reproducibility and homogeneity of the deposits in the presence of air fluctuations. This model was implemented in MATLAB and validated in real operating conditions. The results showed that a print head with a 50 mum diameter aperture will generate microdroplets with diameters between 30 and 60 microns with a maximum placement error on the substrate of the order of +/- 20 microns. We estimated that filling TSVs with an opening of 70 microns and higher is possible with our inkjet DOD (non defined) process. Finally, we experimentally addressed the vias filling by studying the behavior of nanoparticles in the vias during the evaporation of the carrier fluid and the annealing of the gold/tin alloy nanoparticles of eutectic composition. This last step revealed the incompatibility of non-homogenous AuSn alloy particles with the temperature window requirement used during sintering. To overcome this defect we replaced the Au80Sn20 by tin nanoparticles to complete our analysis of the impact of the use of PVP in the suspension of nanoparticles on the resistivity after annealing in the vias. Most aspects of this project being interrelated, much attention has been paid to the study of the influence of the various parameters on the quality of prints realized. The main conclusion is that we are able to validate the use of inkjet technologies as an alternative to perform the filling of TSVs by metal alloy nanoparticles. This conclusion is subject to the feasibility of the adaptation of our suspension and annealing methods to nanopowders alloys other than gold/tin and tin.
[Application of acupoint massage in postpartum hypogalactia in puerpera].
Zhu, Yunfei; Liu, Yuling; Quan, Xiaoming
2018-01-12
To evaluate the effects of acupoint massage for postpartum hypogalactia in puerpera. A total of 60 puerpera of cesarean section were randomized into an observation group and a control group, 30 cases in each one. In the observation group, 2 cases were dropped out. Finally, there were 28 cases in the observation group and 30 cases in the control group. In the control group, the routine nursing after operation in obstetrics department was given, guiding maternal breastfeeding and postpartum health education. In the observation group, on the basis of the treatment as the control group, the corresponding acupoints were selected from the breast related meridians for massage. Acupoint massage was given since the 3rd day after operation, 8:00 am to 9:00 am, once a day, 1 min at one acupoint, continuously for 5 days. The lactation volume, breast filling, galactostasis and milk viscosity were compared in the parturient of the two groups. The clinical therapeutic effects were compared between the two groups. From the 1st to the 2nd days, the differences were not significant in lactation volume, breast filling and galactostasis score between the two groups (all P >0.05). From the 3rd to 5th days, the lactation volume, breast filling and galactostasis score in the observation group were all lower than those in the control group (all P <0.01). The difference in milk viscosity was not significant in the first 4 days between the two groups (all P >0.05). On the 5th day, the score of milk viscosity in the observation group was lower than that in the control group ( P <0.01). The cured rate was 64.3% (18/28) in the observation group, which was better than 13.3% (4/30) in the control group ( P <0.05). Massage at the acupoints from the breast related meridians effectively promotes the lactation secretion in puerpera of postpartum hypogalactia and alleviates breast distention.
Voeller, Rochus K.; Aziz, Abdulhameed; Maniar, Hersh S.; Ufere, Nneka N.; Taggar, Ajay K.; Bernabe, Noel J.; Cupps, Brian P.
2011-01-01
Increased right atrial (RA) and ventricular (RV) chamber volumes are a late maladaptive response to chronic pulmonary hypertension. The purpose of the current investigation was to characterize the early compensatory changes that occur in the right heart during chronic RV pressure overload before the development of chamber dilation. Magnetic resonance imaging with radiofrequency tissue tagging was performed on dogs at baseline and after 10 wk of pulmonary artery banding to yield either mild RV pressure overload (36% rise in RV pressure; n = 5) or severe overload (250% rise in RV pressure; n = 4). The RV free wall was divided into three segments within a midventricular plane, and circumferential myocardial strain was calculated for each segment, the septum, and the left ventricle. Chamber volumes were calculated from stacked MRI images, and RA mechanics were characterized by calculating the RA reservoir, conduit, and pump contribution to RV filling. With mild RV overload, there were no changes in RV strain or RA function. With severe RV overload, RV circumferential strain diminished by 62% anterior (P = 0.04), 42% inferior (P = 0.03), and 50% in the septum (P = 0.02), with no change in the left ventricle (P = 0.12). RV filling became more dependent on RA conduit function, which increased from 30 ± 9 to 43 ± 13% (P = 0.01), than on RA reservoir function, which decreased from 47 ± 6 to 33 ± 4% (P = 0.04), with no change in RA pump function (P = 0.94). RA and RV volumes and RV ejection fraction were unchanged from baseline during either mild (P > 0.10) or severe RV pressure overload (P > 0.53). In response to severe RV pressure overload, RV myocardial strain is segmentally diminished and RV filling becomes more dependent on RA conduit rather than reservoir function. These compensatory mechanisms of the right heart occur early in chronic RV pressure overload before chamber dilation develops. PMID:21926343
Vitale, Jacopo A; Bassani, Tito; Galbusera, Fabio; Bianchi, Alberto; Martinelli, Nicolò
2017-09-22
Previous studies attempted to identify possible risk factors for acute and overuse injuries in several sports disciplines such as running, gymnastics or team sports. Given the lack of scientific works focused on risk factors for lower limb injuries in martial arts, the present study was aimed to investigate foot anatomy, anthropometric measures, and other background information as possible risk factors of injury in barefoot athletes practicing judo, karate, kung fu, thai boxe, or aikido. In addition, the injury rates were evaluated in relation with the different martial art styles. One group of 130 martial artists was retrospectively evaluated. Data of three foot morphological variables were collected: navicular height (NH), navicular drop (ND) and the rear foot (RF). In addition, each participant filled an interview questionnaire providing the following information: age, sex, body weight, height, BMI, hours of training per week, the kind of injury occurred to the lower limbs in the preceding year. Of 130 subjects, 70 (53.8%) did not sustain injuries, 35 (27.0%) suffered an acute injury and the remaining 25 (19.2%) reported an overuse injury. No significant differences were observed in the injury rates in relation to style and kind of martial art. Age, training volume and BMI were found as significant predictors of injury, while NH, ND and RF were not able to predict acute or overuse injury at lower limbs. The injury rates were similar in karate, judo, kung fu, aikido, and thai boxe. The foot morphology variables were not related with the presence or absence of acute and overuse injuries. Conversely, older and heavier martial artists, performing more hours of barefoot training, are at higher risk of acute and overuse injury. Athletic trainers should strongly take into account the present information in order to develop more accurate and specific injury prevention programs for martial artists.