40 CFR 91.421 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Pump—Constant Volume Sampler (PDP-CVS) system with a heat exchanger, or a Critical Flow Venturi—Constant Volume Sampler (CFV-CVS) system with CVS sample probes and/or a heat exchanger or electronic flow... sampling point. (ii) For the CFV-CVS, either a heat exchanger or electronic flow compensation is required...
40 CFR 91.421 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Pump—Constant Volume Sampler (PDP-CVS) system with a heat exchanger, or a Critical Flow Venturi—Constant Volume Sampler (CFV-CVS) system with CVS sample probes and/or a heat exchanger or electronic flow... sampling point. (ii) For the CFV-CVS, either a heat exchanger or electronic flow compensation is required...
40 CFR 91.421 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Pump—Constant Volume Sampler (PDP-CVS) system with a heat exchanger, or a Critical Flow Venturi—Constant Volume Sampler (CFV-CVS) system with CVS sample probes and/or a heat exchanger or electronic flow... sampling point. (ii) For the CFV-CVS, either a heat exchanger or electronic flow compensation is required...
40 CFR 90.421 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Volume Sampler (PDP-CVS) system with a heat exchanger, or a Critical Flow Venturi—Constant Volume Sampler (CFV-CVS) system with CFV sample probes and/or a heat exchanger or electronic flow compensation. Figure... sampling point. (ii) For the CFV-CVS, either a heat exchanger or electronic flow compensation is required...
40 CFR 90.421 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Volume Sampler (PDP-CVS) system with a heat exchanger, or a Critical Flow Venturi—Constant Volume Sampler (CFV-CVS) system with CFV sample probes and/or a heat exchanger or electronic flow compensation. Figure... sampling point. (ii) For the CFV-CVS, either a heat exchanger or electronic flow compensation is required...
40 CFR 90.421 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Volume Sampler (PDP-CVS) system with a heat exchanger, or a Critical Flow Venturi—Constant Volume Sampler (CFV-CVS) system with CFV sample probes and/or a heat exchanger or electronic flow compensation. Figure... sampling point. (ii) For the CFV-CVS, either a heat exchanger or electronic flow compensation is required...
Dilution effects on ultrafine particle emissions from Euro 5 and Euro 6 diesel and gasoline vehicles
NASA Astrophysics Data System (ADS)
Louis, Cédric; Liu, Yao; Martinet, Simon; D'Anna, Barbara; Valiente, Alvaro Martinez; Boreave, Antoinette; R'Mili, Badr; Tassel, Patrick; Perret, Pascal; André, Michel
2017-11-01
Dilution and temperature used during sampling of vehicle exhaust can modify particle number concentration and size distribution. Two experiments were performed on a chassis dynamometer to assess exhaust dilution and temperature on particle number and particle size distribution for Euro 5 and Euro 6 vehicles. In the first experiment, the effects of dilution (ratio from 8 to 4 000) and temperature (ranging from 50 °C to 150 °C) on particle quantification were investigated directly from tailpipe for a diesel and a gasoline Euro 5 vehicles. In the second experiment, particle emissions from Euro 6 diesel and gasoline vehicles directly sampled from the tailpipe were compared to the constant volume sampling (CVS) measurements under similar sampling conditions. Low primary dilutions (3-5) induced an increase in particle number concentration by a factor of 2 compared to high primary dilutions (12-20). Low dilution temperatures (50 °C) induced 1.4-3 times higher particle number concentration than high dilution temperatures (150 °C). For the Euro 6 gasoline vehicle with direct injection, constant volume sampling (CVS) particle number concentrations were higher than after the tailpipe by a factor of 6, 80 and 22 for Artemis urban, road and motorway, respectively. For the same vehicle, particle size distribution measured after the tailpipe was centred on 10 nm, and particles were smaller than the ones measured after CVS that was centred between 50 nm and 70 nm. The high particle concentration (≈106 #/cm3) and the growth of diameter, measured in the CVS, highlighted aerosol transformations, such as nucleation, condensation and coagulation occurring in the sampling system and this might have biased the particle measurements.
Computer vision system for egg volume prediction using backpropagation neural network
NASA Astrophysics Data System (ADS)
Siswantoro, J.; Hilman, M. Y.; Widiasri, M.
2017-11-01
Volume is one of considered aspects in egg sorting process. A rapid and accurate volume measurement method is needed to develop an egg sorting system. Computer vision system (CVS) provides a promising solution for volume measurement problem. Artificial neural network (ANN) has been used to predict the volume of egg in several CVSs. However, volume prediction from ANN could have less accuracy due to inappropriate input features or inappropriate ANN structure. This paper proposes a CVS for predicting the volume of egg using ANN. The CVS acquired an image of egg from top view and then processed the image to extract its 1D and 2 D size features. The features were used as input for ANN in predicting the volume of egg. The experiment results show that the proposed CSV can predict the volume of egg with a good accuracy and less computation time.
Code of Federal Regulations, 2013 CFR
2013-07-01
... use of a PDP-CVS, CFV-CVS (or a CFV-EFC-CVS), sample system with heat exchanger connected to a dilution tunnel. The heat exchanger is not required for the CFV-CVS or EFC-CFV-CVS if electronic flow... the mixture, but below 250 °F (121 °C) prior to the test and during breaks in testing (insulation may...
Code of Federal Regulations, 2014 CFR
2014-07-01
... use of a PDP-CVS, CFV-CVS (or a CFV-EFC-CVS), sample system with heat exchanger connected to a dilution tunnel. The heat exchanger is not required for the CFV-CVS or EFC-CFV-CVS if electronic flow... the mixture, but below 250 °F (121 °C) prior to the test and during breaks in testing (insulation may...
Code of Federal Regulations, 2012 CFR
2012-07-01
... use of a PDP-CVS, CFV-CVS (or a CFV-EFC-CVS), sample system with heat exchanger connected to a dilution tunnel. The heat exchanger is not required for the CFV-CVS or EFC-CFV-CVS if electronic flow... the mixture, but below 250 °F (121 °C) prior to the test and during breaks in testing (insulation may...
Code of Federal Regulations, 2010 CFR
2010-07-01
... use of a PDP-CVS, CFV-CVS (or a CFV-EFC-CVS), sample system with heat exchanger connected to a dilution tunnel. The heat exchanger is not required for the CFV-CVS or EFC-CFV-CVS if electronic flow... the mixture, but below 250 °F (121 °C) prior to the test and during breaks in testing (insulation may...
An Hα-selected sample of cataclysmic variables - I. Observations of newly discovered systems
NASA Astrophysics Data System (ADS)
Pretorius, Magaretha L.; Knigge, Christian
2008-04-01
Strong selection effects are present in observational samples of cataclysmic variables (CVs), complicating comparisons to theoretical predictions. The selection criteria used to define most CV samples discriminate heavily against the discovery of short-period, intrinsically faint systems. The situation can be improved by selecting CVs for the presence of emission lines. For this reason, we have constructed a homogeneous sample of CVs selected on the basis of Hα emission. We present discovery observations of the 14 CVs and two additional CV candidates found in this search. The orbital periods of 11 of the new CVs were measured; all are above 3 h. There are two eclipsing systems in the sample, and one in which we observed a quasi-periodic modulation on a ~1000s time-scale. We also detect the secondary star in the spectrum of one system, and measure its spectral type. Several of the new CVs have the spectroscopic appearance of nova-like variables, and a few display what may be SW Sex star behaviour. In a companion paper, we discuss the implications of this new sample for CV evolution.
The role of abnormal fetal heart rate in scheduling chorionic villus sampling.
Yagel, S; Anteby, E; Ron, M; Hochner-Celnikier, D; Achiron, R
1992-09-01
To assess the value of fetal heart rate (FHR) measurements in predicting spontaneous fetal loss in pregnancies scheduled for chorionic villus sampling (CVS). A prospective descriptive study. Two hospital departments of obstetrics and gynaecology in Israel. 114 women between 9 and 11 weeks gestation scheduled for chorionic villus sampling (CVS). Fetal heart rate was measured by transvaginal Doppler ultrasound and compared with a monogram established from 75 fetuses. Whenever a normal FHR was recorded, CVS was performed immediately. 106 women had a normal FHR and underwent CVS; two of these pregnancies ended in miscarriage. In five pregnancies no fetal heart beats could be identified and fetal death was diagnosed. In three pregnancies an abnormal FHR was recorded and CVS was postponed; all three pregnancies ended in miscarriage within 2 weeks. Determination of FHR correlated with crown-rump length could be useful in predicting spontaneous miscarriage before performing any invasive procedure late in the first trimester.
Charting molecular free-energy landscapes with an atlas of collective variables
NASA Astrophysics Data System (ADS)
Hashemian, Behrooz; Millán, Daniel; Arroyo, Marino
2016-11-01
Collective variables (CVs) are a fundamental tool to understand molecular flexibility, to compute free energy landscapes, and to enhance sampling in molecular dynamics simulations. However, identifying suitable CVs is challenging, and is increasingly addressed with systematic data-driven manifold learning techniques. Here, we provide a flexible framework to model molecular systems in terms of a collection of locally valid and partially overlapping CVs: an atlas of CVs. The specific motivation for such a framework is to enhance the applicability and robustness of CVs based on manifold learning methods, which fail in the presence of periodicities in the underlying conformational manifold. More generally, using an atlas of CVs rather than a single chart may help us better describe different regions of conformational space. We develop the statistical mechanics foundation for our multi-chart description and propose an algorithmic implementation. The resulting atlas of data-based CVs are then used to enhance sampling and compute free energy surfaces in two model systems, alanine dipeptide and β-D-glucopyranose, whose conformational manifolds have toroidal and spherical topologies.
Burton, Carmen A.
2008-01-01
Biotic communities and environmental conditions can be highly variable between natural ecosystems. The variability of natural assemblages should be considered in the interpretation of any ecological study when samples are either spatially or temporally distributed. Little is known about biotic variability in the Santa Ana River Basin. In this report, the lotic community and habitat assessment data from ecological studies done as part of the U.S. Geological Survey's National Water-Quality Assessment (NAWQA) program are used for a preliminary assessment of variability in the Santa Ana Basin. Habitat was assessed, and benthic algae, benthic macroinvertebrate, and fish samples were collected at four sites during 1999-2001. Three of these sites were sampled all three years. One of these sites is located in the San Bernardino Mountains, and the other two sites are located in the alluvial basin. Analysis of variance determined that the three sites with multiyear data were significantly different for 41 benthic algae metrics and 65 macroinvertebrate metrics and fish communities. Coefficients of variation (CVs) were calculated for the habitat measurements, metrics of benthic algae, and macroinvertebrate data as measures of variability. Annual variability of habitat data was generally greater at the mountain site than at the basin sites. The mountain site had higher CVs for water temperature, depth, velocity, canopy angle, streambed substrate, and most water-quality variables. In general, CVs of most benthic algae metrics calculated from the richest-targeted habitat (RTH) samples were greater at the mountain site. In contrast, CVs of most benthic algae metrics calculated from depositional-targeted habitat (DTH) samples were lower at the mountain site. In general, CVs of macroinvertebrate metrics calculated from qualitative multihabitat (QMH) samples were lower at the mountain site. In contrast, CVs of many metrics calculated from RTH samples were greater at the mountain site than at one of the basin sites. Fish communities were more variable at the basin sites because more species were present at these sites. Annual variability of benthic algae metrics was related to annual variability in habitat variables. The CVs of benthic algae metrics related to the most CVs of habitat variables included QMH taxon richness, the RTH percentage richness, RTH abundance of tolerant taxa, RTH percentage richness of halophilic diatoms, RTH percentage abundance of sestonic diatoms, DTH percentage richness of nitrogen heterotrophic diatoms, and DTH pollution tolerance index. The CVs of macroinvertebrate metrics related to the most CVs of habitat variables included the RTH trichoptera, RTH EPT, RTH scraper richness, RTH nonchironomid dipteran abundance (in percent), and RTH EPA (U.S. Environmental Protection Agency) tolerance, which is based on abundance. Many of the CVs of habitat variables related to CVs of macroinvertebrate metrics were the same habitat variables that were related to the CVs of benthic algae metrics. On the basis of these results, annual variability may have a role in the relationship of benthic algae and macroinvertebrates assemblages with habitat and water quality in the Santa Ana Basin. This report provides valuable baseline data on the variability of biological communities in the Santa Ana Basin.
Estimating traffic volumes for signalized intersections using connected vehicle data
Zheng, Jianfeng; Liu, Henry X.
2017-04-17
Recently connected vehicle (CV) technology has received significant attention thanks to active pilot deployments supported by the US Department of Transportation (USDOT). At signalized intersections, CVs may serve as mobile sensors, providing opportunities of reducing dependencies on conventional vehicle detectors for signal operation. However, most of the existing studies mainly focus on scenarios that penetration rates of CVs reach certain level, e.g., 25%, which may not be feasible in the near future. How to utilize data from a small number of CVs to improve traffic signal operation remains an open question. In this work, we develop an approach to estimatemore » traffic volume, a key input to many signal optimization algorithms, using GPS trajectory data from CV or navigation devices under low market penetration rates. To estimate traffic volumes, we model in this paper vehicle arrivals at signalized intersections as a time-dependent Poisson process, which can account for signal coordination. The estimation problem is formulated as a maximum likelihood problem given multiple observed trajectories from CVs approaching to the intersection. An expectation maximization (EM) procedure is derived to solve the estimation problem. Two case studies were conducted to validate our estimation algorithm. One uses the CV data from the Safety Pilot Model Deployment (SPMD) project, in which around 2800 CVs were deployed in the City of Ann Arbor, MI. The other uses vehicle trajectory data from users of a commercial navigation service in China. Mean absolute percentage error (MAPE) of the estimation is found to be 9–12%, based on benchmark data manually collected and data from loop detectors. Finally, considering the existing scale of CV deployments, the proposed approach could be of significant help to traffic management agencies for evaluating and operating traffic signals, paving the way of using CVs for detector-free signal operation in the future.« less
Estimating traffic volumes for signalized intersections using connected vehicle data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zheng, Jianfeng; Liu, Henry X.
Recently connected vehicle (CV) technology has received significant attention thanks to active pilot deployments supported by the US Department of Transportation (USDOT). At signalized intersections, CVs may serve as mobile sensors, providing opportunities of reducing dependencies on conventional vehicle detectors for signal operation. However, most of the existing studies mainly focus on scenarios that penetration rates of CVs reach certain level, e.g., 25%, which may not be feasible in the near future. How to utilize data from a small number of CVs to improve traffic signal operation remains an open question. In this work, we develop an approach to estimatemore » traffic volume, a key input to many signal optimization algorithms, using GPS trajectory data from CV or navigation devices under low market penetration rates. To estimate traffic volumes, we model in this paper vehicle arrivals at signalized intersections as a time-dependent Poisson process, which can account for signal coordination. The estimation problem is formulated as a maximum likelihood problem given multiple observed trajectories from CVs approaching to the intersection. An expectation maximization (EM) procedure is derived to solve the estimation problem. Two case studies were conducted to validate our estimation algorithm. One uses the CV data from the Safety Pilot Model Deployment (SPMD) project, in which around 2800 CVs were deployed in the City of Ann Arbor, MI. The other uses vehicle trajectory data from users of a commercial navigation service in China. Mean absolute percentage error (MAPE) of the estimation is found to be 9–12%, based on benchmark data manually collected and data from loop detectors. Finally, considering the existing scale of CV deployments, the proposed approach could be of significant help to traffic management agencies for evaluating and operating traffic signals, paving the way of using CVs for detector-free signal operation in the future.« less
Holmén, Britt A; Ayala, Alberto
2002-12-01
This paper addresses how current technologies effective for reducing PM emissions of heavy-duty engines may affect the physical characteristics of the particles emitted. Three in-use transit bus configurations were compared in terms of submicron particle size distributions using simultaneous SMPS measurements under two dilution conditions, a minidiluter and the legislated constant volume sampler (CVS). The compressed natural gas (CNG)-fueled and diesel particulate filter (DPF)-equipped diesel configurations are two "green" alternatives to conventional diesel engines. The CNG bus in this study did not have an oxidation catalyst whereas the diesel configurations (with and without particulate filter) employed catalysts. The DPF was a continuously regenerating trap (CRT). Particle size distributions were collected between 6 and 237 nm using 2-minute SMPS scans during idle and 55 mph steady-state cruise operation. Average particle size distributions collected during idle operation of the diesel baseline bus operating on ultralow sulfur fuel showed evidence for nanoparticle growth under CVS dilution conditions relative to the minidiluter. The CRT effectively reduced both accumulation and nuclei mode concentrations by factors of 10-100 except under CVS dilution conditions where nuclei mode concentrations were measured during 55 mph steady-state cruise that exceeded baseline diesel concentrations. The CVS data suggest some variability in trap performance. The CNG bus had accumulation mode concentrations 10-100x lower than the diesel baseline but often displayed large nuclei modes, especially under CVS dilution conditions. Partly this may be explained by the lack of an oxidation catalyst on the CNG, but differences between the minidiluter and CVS size distributions suggest that dilution ratio, temperature-related wall interactions, and differences in tunnel background between the diluters contributed to creating nanoparticle concentrations that sometimes exceeded diesel baseline concentrations when driving under load. The results do not support use of CVS dilution methodology for ultrafine particle sampling, and, despite attention to collection of tunnel blanks in this study, results indicate that a protocol needs to be determined and prescribed for taking into account tunnel blank "emissions" to obtain meaningful comparisons between different technologies. Of critical importance is determining how temperature differences between tunnel blank and test cycle sampling compare in terms of background particle numbers. Total particle number concentrations for the minidiluter sampling point were not significantly different for the two alternative technologies when considering all the steady-cycle data collected. Concentrations ranged from 0.8 to 3 x 10(6) for the baseline bus operating on ultralow sulfur fuel, from 0.5 to 9 x 10(4) for the diesel bus equipped with the CRT filter, and from 1 to 8 x 10(4) particles/cc for the CNG bus.
Ranasinghe, P; Wathurapatha, W S; Perera, Y S; Lamabadusuriya, D A; Kulatunga, S; Jayawardana, N; Katulanda, P
2016-03-09
Computer vision syndrome (CVS) is a group of visual symptoms experienced in relation to the use of computers. Nearly 60 million people suffer from CVS globally, resulting in reduced productivity at work and reduced quality of life of the computer worker. The present study aims to describe the prevalence of CVS and its associated factors among a nationally-representative sample of Sri Lankan computer workers. Two thousand five hundred computer office workers were invited for the study from all nine provinces of Sri Lanka between May and December 2009. A self-administered questionnaire was used to collect socio-demographic data, symptoms of CVS and its associated factors. A binary logistic regression analysis was performed in all patients with 'presence of CVS' as the dichotomous dependent variable and age, gender, duration of occupation, daily computer usage, pre-existing eye disease, not using a visual display terminal (VDT) filter, adjusting brightness of screen, use of contact lenses, angle of gaze and ergonomic practices knowledge as the continuous/dichotomous independent variables. A similar binary logistic regression analysis was performed in all patients with 'severity of CVS' as the dichotomous dependent variable and other continuous/dichotomous independent variables. Sample size was 2210 (response rate-88.4%). Mean age was 30.8 ± 8.1 years and 50.8% of the sample were males. The 1-year prevalence of CVS in the study population was 67.4%. Female gender (OR: 1.28), duration of occupation (OR: 1.07), daily computer usage (1.10), pre-existing eye disease (OR: 4.49), not using a VDT filter (OR: 1.02), use of contact lenses (OR: 3.21) and ergonomics practices knowledge (OR: 1.24) all were associated with significantly presence of CVS. The duration of occupation (OR: 1.04) and presence of pre-existing eye disease (OR: 1.54) were significantly associated with the presence of 'severe CVS'. Sri Lankan computer workers had a high prevalence of CVS. Female gender, longer duration of occupation, higher daily computer usage, pre-existing eye disease, not using a VDT filter, use of contact lenses and higher ergonomics practices knowledge all were associated with significantly with the presence of CVS. The factors associated with the severity of CVS were the duration of occupation and presence of pre-existing eye disease.
Detection and Molecular Characterization of Gemycircularvirus from Environmental Samples in Brazil.
da Silva Assis, Matheus Ribeiro; Vieira, Carmen Baur; Fioretti, Julia Monassa; Rocha, Mônica Simões; de Almeida, Pedro Ivo Neves; Miagostovich, Marize Pereira; Fumian, Tulio Machado
2016-12-01
Gemycircularvirus (GemyCV) is a group of viruses which has been recently proposed as a new viral genus detected in fecal and environmental samples around the world. GemyCVs have been detected in human blood, brain tissue, cerebrospinal fluid, and stool sample. In the present study, we demonstrate for the first time, through molecular detection and characterization, the presence of GemyCVs in environmental samples from Brazil. Our results show a percentage of positivity ranging from 69 (25/36) to 97 % (35/36) in river water samples collected in Manaus, Amazon region, and wastewater from a wastewater treatment plant located in Rio de Janeiro, respectively, revealing GemyCVs as an important environmental contaminant.
40 CFR 86.1309-90 - Exhaust gas sampling system; Otto-cycle and non-petroleum-fueled engines.
Code of Federal Regulations, 2011 CFR
2011-07-01
... gasoline-fueled, natural gas-fueled, liquefied petroleum gas-fueled or methanol-fueled engines. In the CVS... test period. (2) Engine exhaust to CVS duct. For methanol-fueled engines, reactions of the exhaust... samples for the bag sample, the methanol sample (Figure N90-2), and the formaldehyde sample (Figure N90-3...
The cataclysmic variables from the Palomar-Green survey
NASA Astrophysics Data System (ADS)
Ringwald, F. A.
1993-09-01
This thesis explores the cataclysmic variables (CVs) found by the Palomar-Green (PG) survey. This is the first compilation of a statistically complete sample of CVs found by ultraviolet color excess, and not outburst behavior. Blue and red follow-up spectrophotometry suggests that 22 of 68 objects classified originally as CVs are hot subdwarfs. Cool companions may be mimicking CVs' flat energy distributions, although the possibility remains that some are face-on CVs. Spectra taken with the International Ultraviolet Explorer satellite prove useful for distinguishing difficult cases. With the CV sample defined, the orbital periods for eleven systems are investigated with radial velocity studies. At 16th magnitude, CV number counts increase by 2.3 mag-1, although this may level off. The luminosity function is examined for the first time, and a trend toward higher space density at low luminosity is suspected. Outburst properties are compiled, and low-luminosity dwarf novae inflate the total space density to 6 x 10-6 pc-3. I describe all the PG CVs and candidate objects, and show spectra for most. This sample should be useful for population studies, such as measuring the space density with trigonometric parallaxes, or finding the fraction of eclipsing CVs. A new class of nova-likes, the SW Sextantis stars, is characterized by absorption events of the emission lines at spectroscopic phase 0.5, accompanied by large phase lags between the lightcurves and the radial velocity curves and strong high-excitation emission. There are at least six such CVs in this sample of 33, so this mysterious behavior must be common and not peculiar, as previously thought. Five of these six objects eclipse. Serendipitous results for individual CVs include finding low-frequency quasi-periodic variations in the radial velocity curve of the dwarf nova BZ Ursae Majoris. While erratic from epoch to epoch, these are too coherent to be pure noise. Another dwarf nova, HX Pegasi, is caught with time-resolved spectrophotometry on the rise to outburst. This is the second-ever such observation, and the first with red spectra. HX Pegasi is also confirmed as having a novel subdwarf-K red star.
Marshall, Nicole E; Fraley, Gwen; Feist, Cori; Burns, Michael J; Pereira, Leonardo
2012-08-01
To determine the prevalence of abnormal karyotype results in women undergoing chorionic villus sampling (CVS) for abnormal first trimester screening compared to CVS for historical indications (advanced maternal age (AMA) or prior aneuploidy). Retrospective cohort of all patients undergoing CVS at Oregon Health & Science University from January 2006 to June 2010. Patients were separated based on CVS indication: (1) positive ultrasound (U/S) or serum screening; or (2) AMA or prior aneuploidy with normal or no screening. Prevalence of abnormal karyotype results were compared between groups. Fetal karyotyping was successful in 500 of 506 CVS procedures performed. 203 CVS were performed for positive screening with 69 abnormal karyotypes (34.0%). 264 CVS were performed for historical indications with 11 abnormal karyotypes (4.2%). This difference was statistically significant (χ(2) 71.9, p < 0.001; OR 11.8 [95% CI 5.8, 24.6]). There were two age-related aneuplodies in AMA women without positive screening. 42 out of 44 AMA women diagnosed with aneuploidy (95.5%) had abnormal U/S and/or serum screening (35 U/S, 4 serum, 3 U/S and serum). Combined ultrasound and serum screening should be recommended to all women, including AMA women, prior to undergoing invasive testing to improve risk-based counseling and minimize morbidity.
Dar, Hanna; Zuck, Chedva; Friedman, Svetlana; Merkshamer, Ruth; Gonen, Ron
2006-08-01
The decision to undergo prenatal testing may be influenced by ethnic or religious factors. To evaluate factors that might influence the decision of pregnant women to choose chorionic villous sampling for prenatal testing. The study group comprised 239 women referred for prenatal diagnosis who elected to undergo CVS. The data were analyzed according to indication, ethnic group and religion. Among women undergoing CVS because of advanced maternal age and anxiety, we noted a significantly high proportion of unbalanced families, i.e., with three or more children of the same gender and deviated gender ratio. We found a significant excess of males among the Jewish families and a significant excess of females among the non-Jewish families. Jews were over-represented in the monogenic group while Christian Arabs were over-represented in the maternal age/anxiety group. The proportion of women who chose CVS for prenatal diagnosis varied according to indication, ethnic group and religion. The data in this study indicate that CVS may have been utilized for balancing families with > or = 3 or more children of the same sex. Christian Arabs chose CVS more often than the other groups. Jewish women may have utilized CVS for family balancing of both sexes, while non-Jews may have utilized CVS for balancing families with > or = 3 daughters.
40 CFR 86.519-90 - Constant volume sampler calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 19 2013-07-01 2013-07-01 false Constant volume sampler calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.519-90 Constant volume sampler calibration. (a) The CVS (Constant Volume Sampler) is calibrated using an accurate flowmeter and restrictor...
40 CFR 86.519-90 - Constant volume sampler calibration.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Constant volume sampler calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.519-90 Constant volume sampler calibration. (a) The CVS (Constant Volume Sampler) is calibrated using an accurate flowmeter and restrictor...
40 CFR 86.519-90 - Constant volume sampler calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Constant volume sampler calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.519-90 Constant volume sampler calibration. (a) The CVS (Constant Volume Sampler) is calibrated using an accurate flowmeter and restrictor...
40 CFR 86.519-90 - Constant volume sampler calibration.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Constant volume sampler calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.519-90 Constant volume sampler calibration. (a) The CVS (Constant Volume Sampler) is calibrated using an accurate flowmeter and restrictor...
40 CFR 86.519-90 - Constant volume sampler calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Constant volume sampler calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.519-90 Constant volume sampler calibration. (a) The CVS (Constant Volume Sampler) is calibrated using an accurate flowmeter and restrictor...
40 CFR 89.422 - Dilute sampling procedures-CVS calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Pressure depression at CVS pump inlet PPI kPa ±.055 kPa Pressure head at CVS pump outlet PPO kPa ±.055 kPa... restricted condition in an increment of pump inlet depression that will yield a minimum of six data points... depression, (kPa). (iii) The correlation function at each test point is then calculated from the calibration...
40 CFR 89.422 - Dilute sampling procedures-CVS calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Pressure depression at CVS pump inlet PPI kPa ±.055 kPa Pressure head at CVS pump outlet PPO kPa ±.055 kPa... restricted condition in an increment of pump inlet depression that will yield a minimum of six data points... depression, (kPa). (iii) The correlation function at each test point is then calculated from the calibration...
40 CFR 90.424 - Dilute sampling procedures-CVS calibration.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Air temperature at CVS pump inlet PTI °C ±1.11 °C. Pressure depression at CVS pump inlet PPI kPa ±0... pump inlet depression that will yield a minimum of six data points for the total calibration. Allow the...: PB = barometric pressure, kPa PPI = Pump inlet depression, kPa. (iii) The correlation function at...
40 CFR 90.424 - Dilute sampling procedures-CVS calibration.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... Air temperature at CVS pump inlet PTI °C ±1.11 °C. Pressure depression at CVS pump inlet PPI kPa ±0... pump inlet depression that will yield a minimum of six data points for the total calibration. Allow the...: PB = barometric pressure, kPa PPI = Pump inlet depression, kPa. (iii) The correlation function at...
40 CFR 90.424 - Dilute sampling procedures-CVS calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... Air temperature at CVS pump inlet PTI °C ±1.11 °C. Pressure depression at CVS pump inlet PPI kPa ±0... pump inlet depression that will yield a minimum of six data points for the total calibration. Allow the...: PB = barometric pressure, kPa PPI = Pump inlet depression, kPa. (iii) The correlation function at...
40 CFR 90.424 - Dilute sampling procedures-CVS calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... Air temperature at CVS pump inlet PTI °C ±1.11 °C. Pressure depression at CVS pump inlet PPI kPa ±0... pump inlet depression that will yield a minimum of six data points for the total calibration. Allow the...: PB = barometric pressure, kPa PPI = Pump inlet depression, kPa. (iii) The correlation function at...
40 CFR 90.424 - Dilute sampling procedures-CVS calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... Air temperature at CVS pump inlet PTI °C ±1.11 °C. Pressure depression at CVS pump inlet PPI kPa ±0... pump inlet depression that will yield a minimum of six data points for the total calibration. Allow the...: PB = barometric pressure, kPa PPI = Pump inlet depression, kPa. (iii) The correlation function at...
40 CFR 89.422 - Dilute sampling procedures-CVS calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Pressure depression at CVS pump inlet PPI kPa ±.055 kPa Pressure head at CVS pump outlet PPO kPa ±.055 kPa... restricted condition in an increment of pump inlet depression that will yield a minimum of six data points... depression, (kPa). (iii) The correlation function at each test point is then calculated from the calibration...
40 CFR 89.422 - Dilute sampling procedures-CVS calibration.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Pressure depression at CVS pump inlet PPI kPa ±.055 kPa Pressure head at CVS pump outlet PPO kPa ±.055 kPa... restricted condition in an increment of pump inlet depression that will yield a minimum of six data points... depression, (kPa). (iii) The correlation function at each test point is then calculated from the calibration...
40 CFR 89.422 - Dilute sampling procedures-CVS calibration.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Pressure depression at CVS pump inlet PPI kPa ±.055 kPa Pressure head at CVS pump outlet PPO kPa ±.055 kPa... restricted condition in an increment of pump inlet depression that will yield a minimum of six data points... depression, (kPa). (iii) The correlation function at each test point is then calculated from the calibration...
40 CFR 1066.125 - Data updating, recording, and control.
Code of Federal Regulations, 2014 CFR
2014-07-01
... minimum recording frequency, such as for sample flow rates from a CVS that does not have a heat exchanger... exhaust flow rate from a CVS with a heat exchanger upstream of the flow measurement 1 Hz. 40 CFR 1065.545§ 1066.425 Diluted exhaust flow rate from a CVS without a heat exchanger upstream of the flow measurement...
[Advantages and limitations of chorionic villous sampling].
Carles, Dominique; Pelluard, Fanny; Mangione, Raphalle; Liquier, Alain; Horovitz, Jacques; Saura, Robert
2009-03-01
Chorionic villous sampling (CVS) has been available for more than twenty years. Together with amniocentesis, it helps the cytogenetician to determine the fetal karyotype for prenatal diagnosis. The choice between these two methods depends on the team and the indication. CVS can now provide sufficient material for both histopathologic and cytogenetic analyses. We evaluated the accuracy of microscopic examination of CVS for detecting primary ovular, uteroplacental vascular (preeclampsia) and inflammatory disorders. Four hundred CVS were examined in the pathology laboratory of Pellegrin Hospital, Bordeaux, France, from January 1995 to February 2008. The results were analyzed according to the indication, the karyotype, the results of placental examination, pregnancy outcome and, when available (following spontaneous or medical termination), fetoplacental findings. The sample was representative of patients requiring CVS for prenatal diagnosis, with respect to maternal age, the stage of pregnancy, and the indications. When used to screen for preeclamsia (prevalence 29.6% in the sample), the sensitivity and specificity of placental biopsy were respectively 56.8% and 87.2% (76.9% in case of intra-uterine growth retardation). When used to screen for chromosomal aberrations (prevalence 7.4%), the specificity was 14.3% and the sensitivity 93.2%. The prevalence of other disorders, and particularly chronic intervillitis, was too low for meaningful analysis. This study shows that histopathologic analysis of chorionic villous samples is useful for detecting the utero-placental vascular origin of intrauterine growth retardation in the absence of other clinical, biological or ultrasound signs, and that it is complementary to cytogenetic analysis. Being a simple and inexpensive examination, histopathologic analysis of CVS could be performed systematically in this indication. Its value and diagnostic signs in other settings need to be determined in larger series.
Measurement of meat color using a computer vision system.
Girolami, Antonio; Napolitano, Fabio; Faraone, Daniela; Braghieri, Ada
2013-01-01
The limits of the colorimeter and a technique of image analysis in evaluating the color of beef, pork, and chicken were investigated. The Minolta CR-400 colorimeter and a computer vision system (CVS) were employed to measure colorimetric characteristics. To evaluate the chromatic fidelity of the image of the sample displayed on the monitor, a similarity test was carried out using a trained panel. The panelists found the digital images of the samples visualized on the monitor very similar to the actual ones (P<0.001). During the first similarity test the panelists observed at the same time both the actual meat sample and the sample image on the monitor in order to evaluate the similarity between them (test A). Moreover, the panelists were asked to evaluate the similarity between two colors, both generated by the software Adobe Photoshop CS3 one using the L, a and b values read by the colorimeter and the other obtained using the CVS (test B); which of the two colors was more similar to the sample visualized on the monitor was also assessed (test C). The panelists found the digital images very similar to the actual samples (P<0.001). As to the similarity (test B) between the CVS- and colorimeter-based colors the panelists found significant differences between them (P<0.001). Test C showed that the color of the sample on the monitor was more similar to the CVS generated color than to the colorimeter generated color. The differences between the values of the L, a, b, hue angle and chroma obtained with the CVS and the colorimeter were statistically significant (P<0.05-0.001). These results showed that the colorimeter did not generate coordinates corresponding to the true color of meat. Instead, the CVS method seemed to give valid measurements that reproduced a color very similar to the real one. Copyright © 2012 Elsevier Ltd. All rights reserved.
40 CFR 91.424 - Dilute sampling procedure-CVS calibration.
Code of Federal Regulations, 2014 CFR
2014-07-01
... temperature at CVS pump inlet PTI °C ±1.11 °C Pressure depression at CVS pump inlet PPI kPa ±0.055 kPa...) Reset the restrictor valve to a more restricted condition in an increment of pump inlet depression that...=Absolute pump inlet pressure, kPa. =PP−PPI Where: PP=barometric pressure, kPa. PPI=Pump inlet depression, k...
40 CFR 91.424 - Dilute sampling procedure-CVS calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
... temperature at CVS pump inlet PTI °C ±1.11 °C Pressure depression at CVS pump inlet PPI kPa ±0.055 kPa...) Reset the restrictor valve to a more restricted condition in an increment of pump inlet depression that...=Absolute pump inlet pressure, kPa. =PP−PPI Where: PP=barometric pressure, kPa. PPI=Pump inlet depression, k...
40 CFR 91.424 - Dilute sampling procedure-CVS calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... temperature at CVS pump inlet PTI °C ±1.11 °C Pressure depression at CVS pump inlet PPI kPa ±0.055 kPa...) Reset the restrictor valve to a more restricted condition in an increment of pump inlet depression that...=Absolute pump inlet pressure, kPa. =PP−PPI Where: PP=barometric pressure, kPa. PPI=Pump inlet depression, k...
40 CFR 91.424 - Dilute sampling procedure-CVS calibration.
Code of Federal Regulations, 2012 CFR
2012-07-01
... temperature at CVS pump inlet PTI °C ±1.11 °C Pressure depression at CVS pump inlet PPI kPa ±0.055 kPa...) Reset the restrictor valve to a more restricted condition in an increment of pump inlet depression that...=Absolute pump inlet pressure, kPa. =PP−PPI Where: PP=barometric pressure, kPa. PPI=Pump inlet depression, k...
40 CFR 91.424 - Dilute sampling procedure-CVS calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
... temperature at CVS pump inlet PTI °C ±1.11 °C Pressure depression at CVS pump inlet PPI kPa ±0.055 kPa...) Reset the restrictor valve to a more restricted condition in an increment of pump inlet depression that...=Absolute pump inlet pressure, kPa. =PP−PPI Where: PP=barometric pressure, kPa. PPI=Pump inlet depression, k...
40 CFR 90.421 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2011 CFR
2011-07-01
... filter and HFID. Determine these gas temperatures by a temperature sensor located immediately upstream of... analytical system description. (a) General. The exhaust gas sampling system described in this section is...-CVS must conform to all of the requirements listed for the exhaust gas PDP-CVS in § 90.420 of this...
40 CFR 90.421 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2010 CFR
2010-07-01
... filter and HFID. Determine these gas temperatures by a temperature sensor located immediately upstream of... analytical system description. (a) General. The exhaust gas sampling system described in this section is...-CVS must conform to all of the requirements listed for the exhaust gas PDP-CVS in § 90.420 of this...
40 CFR Appendix III to Part 86 - Constant Volume Sampler Flow Calibration
Code of Federal Regulations, 2014 CFR
2014-07-01
... ETI °F ±.1°F. Pressure depression upstream of LFE EPI “H20 ±.1“H20. Pressure drop across the LFE matrix EDP “H20 ±.005“H20. Air temperature at CVS pump inlet PTI °F ±.5°F. Pressure depression at CVS... condition in an increment of pump inlet depression (about 4″ H2O) that will yield a minimum of six data...
40 CFR Appendix III to Part 86 - Constant Volume Sampler Flow Calibration
Code of Federal Regulations, 2010 CFR
2010-07-01
... ETI °F ±.1 °F. Pressure depression upstream of LFE EPI “H20 ±.1“H20. Pressure drop across the LFE matrix EDP “H20 ±.005“H20. Air temperature at CVS pump inlet PTI °F ±.5 °F. Pressure depression at CVS... condition in an increment of pump inlet depression (about 4″ H2O) that will yield a minimum of six data...
40 CFR Appendix III to Part 86 - Constant Volume Sampler Flow Calibration
Code of Federal Regulations, 2013 CFR
2013-07-01
... ETI °F ±.1 °F. Pressure depression upstream of LFE EPI “H20 ±.1“H20. Pressure drop across the LFE matrix EDP “H20 ±.005“H20. Air temperature at CVS pump inlet PTI °F ±.5 °F. Pressure depression at CVS... condition in an increment of pump inlet depression (about 4″ H2O) that will yield a minimum of six data...
40 CFR Appendix III to Part 86 - Constant Volume Sampler Flow Calibration
Code of Federal Regulations, 2011 CFR
2011-07-01
... ETI °F ±.1 °F. Pressure depression upstream of LFE EPI “H20 ±.1“H20. Pressure drop across the LFE matrix EDP “H20 ±.005“H20. Air temperature at CVS pump inlet PTI °F ±.5 °F. Pressure depression at CVS... condition in an increment of pump inlet depression (about 4″ H2O) that will yield a minimum of six data...
40 CFR Appendix III to Part 86 - Constant Volume Sampler Flow Calibration
Code of Federal Regulations, 2012 CFR
2012-07-01
... ETI °F ±.1 °F. Pressure depression upstream of LFE EPI “H20 ±.1“H20. Pressure drop across the LFE matrix EDP “H20 ±.005“H20. Air temperature at CVS pump inlet PTI °F ±.5 °F. Pressure depression at CVS... condition in an increment of pump inlet depression (about 4″ H2O) that will yield a minimum of six data...
40 CFR 91.421 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2010 CFR
2010-07-01
... filter and HFID. Determine these gas temperatures by a temperature sensor located immediately upstream of.... (a) General. The exhaust gas sampling system described in this section is designed to measure the...-CVS must conform to all of the requirements listed for the exhaust gas PDP-CVS in § 91.420 of this...
40 CFR 91.421 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2011 CFR
2011-07-01
... filter and HFID. Determine these gas temperatures by a temperature sensor located immediately upstream of.... (a) General. The exhaust gas sampling system described in this section is designed to measure the...-CVS must conform to all of the requirements listed for the exhaust gas PDP-CVS in § 91.420 of this...
Pisarska, Margareta D; Akhlaghpour, Marzieh; Lee, Bora; Barlow, Gillian M; Xu, Ning; Wang, Erica T; Mackey, Aaron J; Farber, Charles R; Rich, Stephen S; Rotter, Jerome I; Chen, Yii-der I; Goodarzi, Mark O; Guller, Seth; Williams, John
2016-11-01
Multiple testing to understand global changes in gene expression based on genetic and epigenetic modifications is evolving. Chorionic villi, obtained for prenatal testing, is limited, but can be used to understand ongoing human pregnancies. However, optimal storage, processing and utilization of CVS for multiple platform testing have not been established. Leftover CVS samples were flash-frozen or preserved in RNAlater. Modifications to standard isolation kits were performed to isolate quality DNA and RNA from samples as small as 2-5 mg. RNAlater samples had significantly higher RNA yields and quality and were successfully used in microarray and RNA-sequencing (RNA-seq). RNA-seq libraries generated using 200 versus 800-ng RNA showed similar biological coefficients of variation. RNAlater samples had lower DNA yields and quality, which improved by heating the elution buffer to 70 °C. Purification of DNA was not necessary for bisulfite-conversion and genome-wide methylation profiling. CVS cells were propagated and continue to express genes found in freshly isolated chorionic villi. CVS samples preserved in RNAlater are superior. Our optimized techniques provide specimens for genetic, epigenetic and gene expression studies from a single small sample which can be used to develop diagnostics and treatments using a systems biology approach in the prenatal period. © 2016 John Wiley & Sons, Ltd. © 2016 John Wiley & Sons, Ltd.
40 CFR 89.419 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2014 CFR
2014-07-01
... requirements are as follows: (1) This sampling system requires the use of a PDP-CVS and a heat exchanger or a CFV-CVS with either a heat exchanger or electronic flow compensation. Figure 2 in appendix A to this..., either a heat exchanger or electronic flow compensation is required (see Figure 3 in appendix A to this...
40 CFR 89.419 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2012 CFR
2012-07-01
... requirements are as follows: (1) This sampling system requires the use of a PDP-CVS and a heat exchanger or a CFV-CVS with either a heat exchanger or electronic flow compensation. Figure 2 in appendix A to this..., either a heat exchanger or electronic flow compensation is required (see Figure 3 in appendix A to this...
40 CFR 89.419 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2013 CFR
2013-07-01
... requirements are as follows: (1) This sampling system requires the use of a PDP-CVS and a heat exchanger or a CFV-CVS with either a heat exchanger or electronic flow compensation. Figure 2 in appendix A to this..., either a heat exchanger or electronic flow compensation is required (see Figure 3 in appendix A to this...
40 CFR 89.419 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2011 CFR
2011-07-01
... requirements are as follows: (1) This sampling system requires the use of a PDP-CVS and a heat exchanger or a CFV-CVS with either a heat exchanger or electronic flow compensation. Figure 2 in appendix A to this..., either a heat exchanger or electronic flow compensation is required (see Figure 3 in appendix A to this...
Spectral gap optimization of order parameters for sampling complex molecular systems
Tiwary, Pratyush; Berne, B. J.
2016-01-01
In modern-day simulations of many-body systems, much of the computational complexity is shifted to the identification of slowly changing molecular order parameters called collective variables (CVs) or reaction coordinates. A vast array of enhanced-sampling methods are based on the identification and biasing of these low-dimensional order parameters, whose fluctuations are important in driving rare events of interest. Here, we describe a new algorithm for finding optimal low-dimensional CVs for use in enhanced-sampling biasing methods like umbrella sampling, metadynamics, and related methods, when limited prior static and dynamic information is known about the system, and a much larger set of candidate CVs is specified. The algorithm involves estimating the best combination of these candidate CVs, as quantified by a maximum path entropy estimate of the spectral gap for dynamics viewed as a function of that CV. The algorithm is called spectral gap optimization of order parameters (SGOOP). Through multiple practical examples, we show how this postprocessing procedure can lead to optimization of CV and several orders of magnitude improvement in the convergence of the free energy calculated through metadynamics, essentially giving the ability to extract useful information even from unsuccessful metadynamics runs. PMID:26929365
NASA Technical Reports Server (NTRS)
Wang, Z. J.; Liu, Yen; Kwak, Dochan (Technical Monitor)
2002-01-01
The framework for constructing a high-order, conservative Spectral (Finite) Volume (SV) method is presented for two-dimensional scalar hyperbolic conservation laws on unstructured triangular grids. Each triangular grid cell forms a spectral volume (SV), and the SV is further subdivided into polygonal control volumes (CVs) to supported high-order data reconstructions. Cell-averaged solutions from these CVs are used to reconstruct a high order polynomial approximation in the SV. Each CV is then updated independently with a Godunov-type finite volume method and a high-order Runge-Kutta time integration scheme. A universal reconstruction is obtained by partitioning all SVs in a geometrically similar manner. The convergence of the SV method is shown to depend on how a SV is partitioned. A criterion based on the Lebesgue constant has been developed and used successfully to determine the quality of various partitions. Symmetric, stable, and convergent linear, quadratic, and cubic SVs have been obtained, and many different types of partitions have been evaluated. The SV method is tested for both linear and non-linear model problems with and without discontinuities.
Maslin, Jérôme; Nicand, Elisabeth; Ambert-Balay, Katia; Fouet, Christine; Kaplon, Jérôme; Haus, Rachel; Pothier, Pierre; Kohli, Evelyne
2008-03-01
Recent advances in molecular diagnostics have allowed us to recognize Human caliciviruses (HuCVs) as important agents of acute diarrhea in industrialized countries. Their prevalence and genetic diversity in developing countries remains unknown. We report on the characterization of HuCVs among adults presenting acute diarrheas in Djibouti; 108 stool samples collected were screened by EIA, RTPCR, or cell cultures for the group A Rotaviruses, Adenoviruses, Astroviruses, and HuCVs, which were further characterized by genotyping. Among stool samples screened for HuCVs, 25.3% were positive. The other enteric viruses were less prevalent. The 11 HuCV strains sequenced revealed a large diversity (3 sapoviruses and 8 noroviruses). GII strains noroviruses were predominant, five were newly described genotypes, and two were recombinant with a pol gene related to GGIIb strains with the particularity to associate a unique pol gene to different capsid genes. These results could help to the knowledge of HuCV infections in Tropical Africa.
Akolekar, R; Beta, J; Picciarelli, G; Ogilvie, C; D'Antonio, F
2015-01-01
To estimate procedure-related risks of miscarriage following amniocentesis and chorionic villus sampling (CVS) based on a systematic review of the literature and a meta-analysis. A search of MEDLINE, EMBASE, CINHAL and The Cochrane Library (2000-2014) was performed to review relevant citations reporting procedure-related complications of amniocentesis and CVS. Only studies reporting data on more than 1000 procedures were included in this review to minimize the effect of bias from smaller studies. Heterogeneity between studies was estimated using Cochran's Q, the I(2) statistic and Egger bias. Meta-analysis of proportions was used to derive weighted pooled estimates for the risk of miscarriage before 24 weeks' gestation. Incidence-rate difference meta-analysis was used to estimate pooled procedure-related risks. The weighted pooled risks of miscarriage following invasive procedures were estimated from analysis of controlled studies including 324 losses in 42 716 women who underwent amniocentesis and 207 losses in 8899 women who underwent CVS. The risk of miscarriage prior to 24 weeks in women who underwent amniocentesis and CVS was 0.81% (95% CI, 0.58-1.08%) and 2.18% (95% CI, 1.61-2.82%), respectively. The background rates of miscarriage in women from the control group that did not undergo any procedures were 0.67% (95% CI, 0.46-0.91%) for amniocentesis and 1.79% (95% CI, 0.61-3.58%) for CVS. The weighted pooled procedure-related risks of miscarriage for amniocentesis and CVS were 0.11% (95% CI, -0.04 to 0.26%) and 0.22% (95% CI, -0.71 to 1.16%), respectively. The procedure-related risks of miscarriage following amniocentesis and CVS are much lower than are currently quoted. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.
Shin, You Jung; Kim, Do Jin; Ryu, Hyun Mee; Kim, Moon Young; Han, Jung Yeol; Choi, June Seek
2016-01-01
Objective To validate quantitative fluorescent polymerase chain reaction (QF-PCR) via chorionic villus sampling (CVS) for the diagnosis of fetal aneuploidies. Methods We retrospectively reviewed the medical records of consecutive pregnant women who had undergone CVS at Cheil General Hospital between December 2009 and June 2014. Only cases with reported QF-PCR before long-term culture (LTC) for conventional cytogenetic analysis were included, and the results of these two methods were compared. Results A total of 383 pregnant women underwent QF-PCR and LTC via CVS during the study period and 403 CVS specimens were collected. The indications of CVS were as follows: abnormal first-trimester ultrasonographic findings, including increased fetal nuchal translucency (85.1%), advanced maternal age (6.8%), previous history of fetal anomalies (4.2%), and positive dual test results for trisomy 21 (3.9%). The results of QF-PCR via CVS were as follows: 76 (18.9%) cases were identified as trisomy 21 (36 cases), 18 (33 cases), or 13 (seven cases), and 4 (1.0%) cases were suspected to be mosaicism. All results of common autosomal trisomies by QF-PCR were consistent with those of LTC and there were no false-positive findings. Four cases suspected as mosaicism in QF-PCR were confirmed as non-mosaic trisomies of trisomy 21 (one case) or trisomy 18 (three cases) in LTC. Conclusion QF-PCR via CVS has the advantage of rapid prenatal screening at an earlier stage of pregnancy for common chromosomal trisomies and thus can reduce the anxiety of parents. In particular, it can be helpful for pregnant women with increased fetal nuchal translucency or abnormal first-trimester ultrasonographic findings. PMID:27896246
tICA-Metadynamics: Accelerating Metadynamics by Using Kinetically Selected Collective Variables.
M Sultan, Mohammad; Pande, Vijay S
2017-06-13
Metadynamics is a powerful enhanced molecular dynamics sampling method that accelerates simulations by adding history-dependent multidimensional Gaussians along selective collective variables (CVs). In practice, choosing a small number of slow CVs remains challenging due to the inherent high dimensionality of biophysical systems. Here we show that time-structure based independent component analysis (tICA), a recent advance in Markov state model literature, can be used to identify a set of variationally optimal slow coordinates for use as CVs for Metadynamics. We show that linear and nonlinear tICA-Metadynamics can complement existing MD studies by explicitly sampling the system's slowest modes and can even drive transitions along the slowest modes even when no such transitions are observed in unbiased simulations.
Tarbell, Sally E.; Millar, Amanda; Laudenslager, Mark; Palmer, Claire; Fortunato, John E.
2016-01-01
This study compared anxiety and physiological responses during the Trier Social Stress Test for Children (TSST-C) in adolescents. 38 subjects (26 females) were enrolled: 11 cyclic vomiting syndrome (CVS), 11 anxiety, and 16 controls. Salivary cortisol, α-amylase and heart rate variability (HRV) were assessed during the TSST-C. Anxiety was measured by the Screen for Childhood Anxiety and Related Emotional Disorders (SCARED), Anxiety Disorders Interview Schedule, and State-Trait Anxiety Inventory for Children (STAI-C). 11 anxiety and 7 CVS subjects had ≥1 anxiety disorder. 82% in the anxiety and CVS groups met criteria for an anxiety disorder on the SCARED. Combining groups, cortisol increased from baseline to recovery during the TSST-C (p = 0.0004) and the stressor to recovery (p = 0.005). α-amylase did not differ during the TSST-C for the total sample, but increased for anxiety compared to controls from baseline to recovery (p = 0.01). HRV decreased during the stressor (p = 0.0001) and increased at recovery (p = 0.004). No associations were found between biomarkers and trait anxiety. Associations were found between baseline HRV and pre-test state anxiety (r = −.406, p = .012) and between recovery HRV and post-test state anxiety (r = −.501, p = .002) for the total sample. Anxiety is prevalent in CVS warranting screening. HRV may serve as a biomarker for evaluating stress as a potential trigger for CVS episodes. State but not trait anxiety was associated with changes in HRV, suggesting acute anxiety may be more relevant in linking stress and CVS episodes. PMID:27554769
40 CFR 86.509-90 - Exhaust gas sampling system.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (insulation may remain in place and/or heating may occur during testing provided maximum temperature is not... equivalent results, and if approved in advance by the Administrator (e.g., a heat exchanger with the CFV-CVS or an electronic flow integrator without a heat exchanger, with the PDP-CVS). (b) Component...
40 CFR 86.509-90 - Exhaust gas sampling system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (insulation may remain in place and/or heating may occur during testing provided maximum temperature is not... equivalent results, and if approved in advance by the Administrator (e.g., a heat exchanger with the CFV-CVS or an electronic flow integrator without a heat exchanger, with the PDP-CVS). (b) Component...
40 CFR 86.509-90 - Exhaust gas sampling system.
Code of Federal Regulations, 2012 CFR
2012-07-01
... (insulation may remain in place and/or heating may occur during testing provided maximum temperature is not... equivalent results, and if approved in advance by the Administrator (e.g., a heat exchanger with the CFV-CVS or an electronic flow integrator without a heat exchanger, with the PDP-CVS). (b) Component...
40 CFR 86.206-94 - Equipment required; overview.
Code of Federal Regulations, 2010 CFR
2010-07-01
... tests. Exhaust from gasoline-fueled vehicles is tested for gaseous emissions using the Constant Volume Sampler (CVS) concept (§ 86.209). Equipment necessary and specifications appear in §§ 86.208 through 86...
Chorionic villus sampling for beta-thalassemia: the first report of experience in Iran.
Akhlaghpoor, Shahram
2006-12-01
Beta-thalassemia is one of the most common hereditary disorders in Iran. The prenatal diagnosis of beta-thalassemia is part of a control program in our country and it began 13 years ago. During the past 8 years the number of procedures has increased significantly as also the legal abortions. This is the first report made on the CVS program in Iran. One thousand six hundred and sixty-one cases of transabdominal Chorionic Villus Sampling (CVS) have been retrospectively evaluated. Among them 1381 cases had inclusion criteria. CVS results, complications and fetal loss rate were evaluated. The distributions of the population at risk were divided between eight regions that have been proposed for beta-thalassemia mapping previously. The mean age of the patients was 26.2 +/- 5.2 years with mean gestational age of 11.4 +/- 1.4 weeks. CVS was successful in all the patients (100%) although 1% required a second procedure. Post CVS fetal loss was 1.45%. Other minor complications were bleeding or spotting (1.81%), amniotic fluid leak (0.5%), small sub-chorionic hematoma (0.58%), severe abdominal pain (0.6%) and severe vasovagal reaction (0.14%). Late complications were seen in 0.21% (oligohydraminos). Approximately 2/3 of the patients were referred from three regions of the country, North (26.8%), South West (22.4%), Central (19.5%) and the remainder (31.3%) were from the other five regions. CVS is a safe and effective method for prenatal diagnosis of beta-thalassemia in countries with a high prevalence as in Iran. The overall complication rate is quite low and acceptable. Fortunately the recent acceptance of legal abortion with respect to Muslim rules has increased the effectiveness of the procedure and made great advances in its application in Iran. Correspondingly, social knowledge has also improved but still there is a gap between the population at risk and the required prenatal diagnosis laboratories and sampling centers. 2006 John Wiley & Sons, Ltd.
How often do surgeons obtain the critical view of safety during laparoscopic cholecystectomy?
Stefanidis, Dimitrios; Chintalapudi, Nikita; Anderson-Montoya, Brittany; Oommen, Bindhu; Tobben, Daniel; Pimentel, Manuel
2017-01-01
The reported incidence (0.16-1.5 %) of bile duct injury (BDI) during laparoscopic cholecystectomy (LC) is higher than during open cholecystectomy and has not decreased over time despite increasing experience with the procedure. The "critical view of safety" (CVS) technique may help to prevent BDI when certain criteria are met prior to division of any structures. This study aimed to evaluate the adherence of practicing surgeons to the CVS criteria during LC and the impact of a training intervention on CVS identification. LC procedures of general surgeons were video-recorded. De-identified recordings were reviewed by a blinded observer and rated on a 6-point scale using the previously published CVS criteria. A coaching program was conducted, and participating surgeons were re-assessed in the same manner. The observer assessed ten LC videos, each involving a different surgeon. The CVS was adequately achieved by two surgeons (20 %). The remaining eight surgeons (80 %) did not obtain adequate CVS prior to division of any structures, despite two surgeons dictating that they did; the mean score of this group was 1.75. After training, five participating surgeons (50 %) scored > 4, and the mean increased from 1.75 (baseline) to 3.75 (p < 0.05). The CVS criteria were not routinely used by the majority of participating surgeons. Further, one-fourth of those who claimed to obtain the CVS did so inadequately. All surgeons who participated in training showed improvement during their post-assessment. Our findings suggest that education of practicing surgeons in the application of the CVS during LC can result in increased implementation and quality of the CVS. Pending studies with larger samples, our findings may partly explain the sustained BDI incidence despite increased experience with LC. Our study also supports the value of direct observation of surgical practices and subsequent training for quality improvement.
NASA Astrophysics Data System (ADS)
Nishida, M.; Okunishi, E.; Nishiura, T.; Kawano, H.; Inamura, T.; S., Ii; Hara, T.
2012-06-01
Four characteristic interface microstructures between habit plane variants (HPVs) in the self-accommodation morphologies of B19‧ martensite in Ti-Ni alloys have been investigated by scanning transmission electron microscopy (STEM). The straight interface of a ? B19‧ type I twin is present at interface I. The relaxation of the transformation strain at interface II is achieved by a volume reduction of the minor correspondence variants (CVs) in the relevant habit plane variants (HPVs). The relaxation of the transformation strain at interface III is mainly due to the formation of a ? B19‧ type I twin between the two major CVs. Subsequently, local strain around the tips of the minor CVs perpendicular to the interface is released by the formation of micro-twins with the ⟨011⟩B19‧ type II and/or ? B19‧ type I relation. The major and minor CVs in each HPV are alternately connected through fine variants with the ? B19‧ type I twin relation parallel to interface IV. The results are compared with macroscopic observations and the predictions of PTMC analysis.
Tarbell, Sally E; Millar, Amanda; Laudenslager, Mark; Palmer, Claire; Fortunato, John E
2017-01-01
This study compared anxiety and physiological responses during the Trier Social Stress Test for Children (TSST-C) in adolescents. 38 subjects (26 females) were enrolled: 11 cyclic vomiting syndrome (CVS), 11 anxiety, and 16 controls. Salivary cortisol, α-amylase and heart rate variability (HRV) were assessed during the TSST-C. Anxiety was measured by the Screen for Childhood Anxiety Related Emotional Disorders (SCARED), Anxiety Disorders Interview Schedule, and State-Trait Anxiety Inventory for Children (STAI-C). 11 anxiety and 7 CVS subjects had ≥1 anxiety disorder. 82% in the anxiety and CVS groups met criteria for an anxiety disorder on the SCARED. Combining groups, cortisol increased from baseline to recovery during the TSST-C (p=0.0004) and the stressor to recovery (p=0.005). α-amylase did not differ during the TSST-C for the total sample, but increased for anxiety compared to controls from baseline to recovery (p=0.01). HRV decreased during the stressor (p=0.0001) and increased at recovery (p=0.004). No associations were found between biomarkers and trait anxiety. Associations were found between baseline HRV and pre-test state anxiety (r=-0.406, p=0.012) and between recovery HRV and post-test state anxiety (r=-0.501, p=0.002) for the total sample. Anxiety is prevalent in CVS warranting screening. HRV may serve as a biomarker for evaluating stress as a potential trigger for CVS episodes. State but not trait anxiety was associated with changes in HRV, suggesting acute anxiety may be more relevant in linking stress and CVS episodes. Copyright © 2016 Elsevier B.V. All rights reserved.
2011-01-01
Background Valve dysfunction is a common cardiovascular pathology. Despite significant clinical research, there is little formal study of how valve dysfunction affects overall circulatory dynamics. Validated models would offer the ability to better understand these dynamics and thus optimize diagnosis, as well as surgical and other interventions. Methods A cardiovascular and circulatory system (CVS) model has already been validated in silico, and in several animal model studies. It accounts for valve dynamics using Heaviside functions to simulate a physiologically accurate "open on pressure, close on flow" law. However, it does not consider real-time valve opening dynamics and therefore does not fully capture valve dysfunction, particularly where the dysfunction involves partial closure. This research describes an updated version of this previous closed-loop CVS model that includes the progressive opening of the mitral valve, and is defined over the full cardiac cycle. Results Simulations of the cardiovascular system with healthy mitral valve are performed, and, the global hemodynamic behaviour is studied compared with previously validated results. The error between resulting pressure-volume (PV) loops of already validated CVS model and the new CVS model that includes the progressive opening of the mitral valve is assessed and remains within typical measurement error and variability. Simulations of ischemic mitral insufficiency are also performed. Pressure-Volume loops, transmitral flow evolution and mitral valve aperture area evolution follow reported measurements in shape, amplitude and trends. Conclusions The resulting cardiovascular system model including mitral valve dynamics provides a foundation for clinical validation and the study of valvular dysfunction in vivo. The overall models and results could readily be generalised to other cardiac valves. PMID:21942971
Three-Dimensional High-Order Spectral Finite Volume Method for Unstructured Grids
NASA Technical Reports Server (NTRS)
Liu, Yen; Vinokur, Marcel; Wang, Z. J.; Kwak, Dochan (Technical Monitor)
2002-01-01
Many areas require a very high-order accurate numerical solution of conservation laws for complex shapes. This paper deals with the extension to three dimensions of the Spectral Finite Volume (SV) method for unstructured grids, which was developed to solve such problems. We first summarize the limitations of traditional methods such as finite-difference, and finite-volume for both structured and unstructured grids. We then describe the basic formulation of the spectral finite volume method. What distinguishes the SV method from conventional high-order finite-volume methods for unstructured triangular or tetrahedral grids is the data reconstruction. Instead of using a large stencil of neighboring cells to perform a high-order reconstruction, the stencil is constructed by partitioning each grid cell, called a spectral volume (SV), into 'structured' sub-cells, called control volumes (CVs). One can show that if all the SV cells are partitioned into polygonal or polyhedral CV sub-cells in a geometrically similar manner, the reconstructions for all the SVs become universal, irrespective of their shapes, sizes, orientations, or locations. It follows that the reconstruction is reduced to a weighted sum of unknowns involving just a few simple adds and multiplies, and those weights are universal and can be pre-determined once for all. The method is thus very efficient, accurate, and yet geometrically flexible. The most critical part of the SV method is the partitioning of the SV into CVs. In this paper we present the partitioning of a tetrahedral SV into polyhedral CVs with one free parameter for polynomial reconstructions up to degree of precision five. (Note that the order of accuracy of the method is one order higher than the reconstruction degree of precision.) The free parameter will be determined by minimizing the Lebesgue constant of the reconstruction matrix or similar criteria to obtain optimized partitions. The details of an efficient, parallelizable code to solve three-dimensional problems for any order of accuracy are then presented. Important aspects of the data structure are discussed. Comparisons with the Discontinuous Galerkin (DG) method are made. Numerical examples for wave propagation problems are presented.
An Observational Study of Cataclysmic Variable Evolution
NASA Astrophysics Data System (ADS)
Araujo-Betancor, Sofia
2004-03-01
In this thesis I present an observational study of the evolution of Cataclysmic Variables (CVs). Disrupted magnetic braking has been the standard paradigm of CV evolution for the past twenty years. Unfortunately, some of its predictions are in strong disagreement with the observations. In recent years, a number of additions/alternatives to the standard model have been proposed. Yet, none have been able to explain all of the features observed in the currently known CV population. The work presented in this thesis is based mainly on a large-scale search for CVs. The primary aim of this project is to resolve the disagreement between theory and observations by eliminating the observational biases of the present CV sample. Here, I use two complementary approaches to search for CVs: (1) from the spectroscopic appearance in the Hamburg Quasar Survey (HQS), and (2) by using a combination of ROSAT and 2MASS archival data. So far, we have discovered 52 new CVs in the HQS and 11 new CVs (the majority of them magnetic) and 1 pre-CV in the ROSAT/2MASS. Follow-up observations of two newly discovered HQS CVs, 1RXS J062518.2+733433 and HS 2331+3905, resulted in the classification of the first as an Intermediate Polar, with P_orb = 283.0 min and P_spin = 19.8 min, and the second as a short orbital period system, P_orb = 81.0 min, harbouring a white dwarf pulsator. In addition, we found that the dominant ~3.5 h radial velocity variation of HS 2331+3905 does not correspond to the orbital period of the system, contrary to all other CVs. Despite its novel selection criterion, the HQS does not provide many short-period CVs -- even though tests with the known CVs included in the survey have shown that it is very sensitive to those objects. The biggest surprise in the new HQS sample is the discovery of many new SW Sex stars. The clustering of SW Sex stars in the 3-4 h period range is probably an important feature in the evolution of CVs that we currently do not understand at all. To improve our chances of understanding what is going on in that period range, we need accurate system parameters for these stars, which is difficult mainly because of their defining characteristics. I have used HST data of one of the sporadic low states of the SW Sex star DW UMa to derive its system parameters. The success of this study is the first step towards the otherwise impossible task of compiling reliable system parameters for the SW Sex stars.
New cataclysmic variables and other exotic binaries in the globular cluster 47 Tucanae*
NASA Astrophysics Data System (ADS)
Rivera Sandoval, L. E.; van den Berg, M.; Heinke, C. O.; Cohn, H. N.; Lugger, P. M.; Anderson, J.; Cool, A. M.; Edmonds, P. D.; Wijnands, R.; Ivanova, N.; Grindlay, J. E.
2018-04-01
We present 22 new (+3 confirmed) cataclysmic variables (CVs) in the non-core-collapsed globular cluster 47 Tucanae (47 Tuc). The total number of CVs in the cluster is now 43, the largest sample in any globular cluster so far. For the identifications we used near-ultraviolet (NUV) and optical images from the Hubble Space Telescope, in combination with X-ray results from the Chandra X-ray Observatory. This allowed us to build the deepest NUV CV luminosity function of the cluster to date. We found that the CVs in 47 Tuc are more concentrated towards the cluster centre than the main-sequence turn-off stars. We compared our results to the CV populations of the core-collapsed globular clusters NGC 6397 and NGC 6752. We found that 47 Tuc has fewer bright CVs per unit mass than those two other clusters. That suggests that dynamical interactions in core-collapsed clusters play a major role creating new CVs. In 47 Tuc, the CV population is probably dominated by primordial and old dynamically formed systems. We estimated that the CVs in 47 Tuc have total masses of ˜1.4 M⊙. We also found that the X-ray luminosity function of the CVs in the three clusters is bimodal. Additionally, we discuss a possible double degenerate system and an intriguing/unclassified object. Finally, we present four systems that could be millisecond pulsar companions given their X-ray and NUV/optical colours. For one of them we present very strong evidence for being an ablated companion. The other three could be CO or He white dwarfs.
Results from SMAP Validation Experiments 2015 and 2016
NASA Astrophysics Data System (ADS)
Colliander, A.; Jackson, T. J.; Cosh, M. H.; Misra, S.; Crow, W.; Powers, J.; Wood, E. F.; Mohanty, B.; Judge, J.; Drewry, D.; McNairn, H.; Bullock, P.; Berg, A. A.; Magagi, R.; O'Neill, P. E.; Yueh, S. H.
2017-12-01
NASA's Soil Moisture Active Passive (SMAP) mission was launched in January 2015. The objective of the mission is global mapping of soil moisture and freeze/thaw state. Well-characterized sites with calibrated in situ soil moisture measurements are used to determine the quality of the soil moisture data products; these sites are designated as core validation sites (CVS). To support the CVS-based validation, airborne field experiments are used to provide high-fidelity validation data and to improve the SMAP retrieval algorithms. The SMAP project and NASA coordinated airborne field experiments at three CVS locations in 2015 and 2016. SMAP Validation Experiment 2015 (SMAPVEX15) was conducted around the Walnut Gulch CVS in Arizona in August, 2015. SMAPVEX16 was conducted at the South Fork CVS in Iowa and Carman CVS in Manitoba, Canada from May to August 2016. The airborne PALS (Passive Active L-band Sensor) instrument mapped all experiment areas several times resulting in 30 coincidental measurements with SMAP. The experiments included intensive ground sampling regime consisting of manual sampling and augmentation of the CVS soil moisture measurements with temporary networks of soil moisture sensors. Analyses using the data from these experiments have produced various results regarding the SMAP validation and related science questions. The SMAPVEX15 data set has been used for calibration of a hyper-resolution model for soil moisture product validation; development of a multi-scale parameterization approach for surface roughness, and validation of disaggregation of SMAP soil moisture with optical thermal signal. The SMAPVEX16 data set has been already used for studying the spatial upscaling within a pixel with highly heterogeneous soil texture distribution; for understanding the process of radiative transfer at plot scale in relation to field scale and SMAP footprint scale over highly heterogeneous vegetation distribution; for testing a data fusion based soil moisture downscaling approach; and for investigating soil moisture impact on estimation of vegetation fluorescence from airborne measurements. The presentation will describe the collected data and showcase some of the most important results achieved so far.
NASA Astrophysics Data System (ADS)
Edmonds, Peter D.; Gilliland, Ronald L.; Heinke, Craig O.; Grindlay, Jonathan E.
2003-10-01
We report time series and variability information for the optical identifications of X-ray sources in 47 Tucanae reported in Paper I (at least 22 cataclysmic variables [CVs] and 29 active binaries). The radial distribution of the CVs is indistinguishable from that of the millisecond pulsars (MSPs) detected by Freire et al. A study of the eight CVs with secure orbital periods (two obtained from the Chandra study of Grindlay et al.) shows that the 47 Tuc CVs have fainter accretion disks, in the V band, than field CVs with similar periods. These faint disks and the faint absolute magnitudes (MV) of the 47 Tuc CVs suggests they have low accretion rates. One possible explanation is that the 47 Tuc objects may be a more representative sample of CVs, down to our detection threshold, than the CVs found in the field (where many low accretion rate systems are believed to be undiscovered), showing the advantages of deep globular cluster observations. The median FX/Fopt value for the 47 Tuc CVs is higher than that of all known classes of field CV, partly because of the faint MV values and partly because of the relatively high X-ray luminosities (LX). The latter are only seen in DQ Her systems in the field, but the 47 Tuc CVs are much fainter optically than most field DQ Her's. Previous work by Edmonds et al. has shown that the four brightest CVs in NGC 6397 have optical spectra and broadband colors that are consistent with DQ Her's having lower than average accretion rates. Some combination of magnetic behavior and low accretion rates may be able to explain our observations, but the results at present are ambiguous, since no class of field CV has distributions of both LX and MV that are consistent with those of the 47 Tuc CVs. The radial distribution of the X-ray detected active binaries is indistinguishable from that of the much larger sample of optical variables (eclipsing and contact binaries and BY Dra variables) detected in previous Wide Field Planetary Camera 2 (WFPC2) studies by Albrow et al. The X-ray properties of these objects (luminosity, hardness ratios, and variability) are consistent with those of active binaries found in field studies, and the FX/Fopt distribution is significantly different from those of the CVs and the MSPs that are detected (or possibly detected) in the optical. Despite these results, we examine the possibility that a few of the active binaries are MSPs with main-sequence companions resulting from double exchanges in the crowded core of 47 Tuc. No solid evidence is found for a significant population of such objects, and therefore, using the methods of Grindlay et al., we estimate that the number of MSPs in 47 Tuc with luminosities above 1030 ergs s-1 is ~30-40, near the previous lower limit. We present the results of a new, deeper search for faint low-mass X-ray binaries (LMXBs) in quiescence. One reasonable and one marginal candidate for optical identification of a quiescent LMXB was found (one is already known). Finally, it is shown that the periods of the blue variables showing little or no evidence for X-ray emission are too long for Roche lobe filling (if the variations are ellipsoidal). These blue variables also show no evidence for the large flickering levels seen in comparably bright CVs. At present we have no satisfactory explanation for these objects, although some may be detached white dwarf-main-sequence star binaries. Based on observations with the NASA/ESA Hubble Space Telescope obtained at STScI, which is operated by AURA, Inc. under NASA contract NAS 5-26555.
Beta, Jaroslaw; Lesmes-Heredia, Cristina; Bedetti, Chiara; Akolekar, Ranjit
2018-04-01
The aim of this paper was to estimate the risk of miscarriage after amniocentesis or chorionic villus sampling (CVS) based on a systematic review of the literature. A search of Medline, Embase, and The Cochrane Library (2000-2017) was carried out to identify studies reporting complications following CVS or amniocentesis. The inclusion criteria for the systematic review were studies reporting results from large controlled studies (N.≥1000 invasive procedures) and those reporting data for pregnancy loss prior to 24 weeks' gestation. Data for cases that had invasive procedure and controls were inputted in contingency tables and risk of miscarriage was estimated for each study. Summary statistics were calculated after taking into account the weighting for each study included in the systematic review. Procedure-related risk of miscarriage was estimated as a weighted risk difference from the summary statistics for cases and controls. The electronic search from the databases yielded 2465 potential citations of which 2431 were excluded, leaving 34 studies for full-text review. The final review included 10 studies for amniocentesis and 6 studies for CVS, which were used to estimate risk of miscarriage in pregnancies that had an invasive procedure and the control pregnancies that did not. The procedure-related risk of miscarriage following amniocentesis was 0.35% (95% confidence interval [CI]: 0.07 to 0.63) and that following CVS was 0.35% (95% CI: -0.31 to 1.00). The procedure-related risks of miscarriage following amniocentesis and CVS are lower than currently quoted to women.
Sanhal, Cem Yasar; Mendilcioglu, Inanc; Ozekinci, Murat; Simsek, Mehmet; Bozkurt, Selen
2015-01-01
To compare the pre-procedural anxiety and depression levels of patients undergoing chorion villus sampling (CVS) and amniocentesis (AC). Patients referred to our department for fetal karyotype analysis with a positive first or second trimester screening test for aneuploidy between January 2013 to June 2015 were included. CVS and AC procedures were performed in patients with gestation periods of between 11-14 and 16-20 weeks, respectively. Anxiety was evaluated using the Spielberger State-Trait Anxiety Inventory (STAI), and depression was assessed using the Beck Depression Inventory II (BDI-II). A total of 1,400 patients were included. Compared to first trimester controls, patients undergoing CVS had significantly higher STAI-state and BDI-II results. Likewise, patients undergoing AC had higher STAI-state and BDI-II scores than controls in the second trimester. In terms of STAI-trait results, no difference was found between the groups. Our results also showed that, compared to AC group, patients undergoing CVS had similar STAI-state, STAI-trait and but higher BDI-II scores. We conclude that evaluating the stress and depression levels of these patients should be one of the routine procedures in pregnancy follow-up.
Sun, Xin; Young, Jennifer; Liu, Jeng-Hung; Newman, David
2018-06-01
The objective of this project was to develop a computer vision system (CVS) for objective measurement of pork loin under industry speed requirement. Color images of pork loin samples were acquired using a CVS. Subjective color and marbling scores were determined according to the National Pork Board standards by a trained evaluator. Instrument color measurement and crude fat percentage were used as control measurements. Image features (18 color features; 1 marbling feature; 88 texture features) were extracted from whole pork loin color images. Artificial intelligence prediction model (support vector machine) was established for pork color and marbling quality grades. The results showed that CVS with support vector machine modeling reached the highest prediction accuracy of 92.5% for measured pork color score and 75.0% for measured pork marbling score. This research shows that the proposed artificial intelligence prediction model with CVS can provide an effective tool for predicting color and marbling in the pork industry at online speeds. Copyright © 2018 Elsevier Ltd. All rights reserved.
Rabies virus quasispecies: Implications for pathogenesis
Morimoto, Kinjiro; Hooper, D. Craig; Carbaugh, Heather; Fu, Zhen Fang; Koprowski, Hilary; Dietzschold, Bernhard
1998-01-01
Passage of the mouse-adapted rabies virus strain CVS-24 (where CVS is challenge virus standard) in BHK cells results in the rapid selection of a dominant variant designated CVS-B2c that differs genotypically and phenotypically from the dominant variant CVS-N2c present in mouse-brain- or neuroblastoma-cell-passaged CVS-24. The glycoprotein of CVS-B2c has 10 amino acid substitutions compared with that of CVS-N2c. Because CVS-B2c can be reproducibly selected in BHK cells, it is likely to be a conserved minor subpopulation of CVS-24. CVS-N2c is more neurotropic in vitro and in vivo than CVS-B2c, which replicates more readily in nonneuronal cells in vitro and in vivo. These characteristics appear to be relevant to the pathogenicity of the two variants. CVS-N2c is more pathogenic for adult mice than CVS-B2c. In contrast, CVS-B2c is more pathogenic for neonatal mice. These differences in pathogenicity are reflected in the selection pattern when mixtures of CVS-N2c and CVS-B2c were used to infect neonatal and adult mice. Although CVS-N2c was highly selected in adult mice, no selection for either variant was seen in neonates, suggesting that certain aspects of development, such as maturation of the nervous and immune systems, may contribute to the selection process. We speculate that the existence of different variants within a rabies virus strain may facilitate the virus in overcoming barriers to its spread, both within the host and between species. PMID:9501231
Rabies virus quasispecies: implications for pathogenesis.
Morimoto, K; Hooper, D C; Carbaugh, H; Fu, Z F; Koprowski, H; Dietzschold, B
1998-03-17
Passage of the mouse-adapted rabies virus strain CVS-24 (where CVS is challenge virus standard) in BHK cells results in the rapid selection of a dominant variant designated CVS-B2c that differs genotypically and phenotypically from the dominant variant CVS-N2c present in mouse-brain- or neuroblastoma-cell-passaged CVS-24. The glycoprotein of CVS-B2c has 10 amino acid substitutions compared with that of CVS-N2c. Because CVS-B2c can be reproducibly selected in BHK cells, it is likely to be a conserved minor subpopulation of CVS-24. CVS-N2c is more neurotropic in vitro and in vivo than CVS-B2c, which replicates more readily in nonneuronal cells in vitro and in vivo. These characteristics appear to be relevant to the pathogenicity of the two variants. CVS-N2c is more pathogenic for adult mice than CVS-B2c. In contrast, CVS-B2c is more pathogenic for neonatal mice. These differences in pathogenicity are reflected in the selection pattern when mixtures of CVS-N2c and CVS-B2c were used to infect neonatal and adult mice. Although CVS-N2c was highly selected in adult mice, no selection for either variant was seen in neonates, suggesting that certain aspects of development, such as maturation of the nervous and immune systems, may contribute to the selection process. We speculate that the existence of different variants within a rabies virus strain may facilitate the virus in overcoming barriers to its spread, both within the host and between species.
ERIC Educational Resources Information Center
Exceptional Parent, 2006
2006-01-01
This article briefly describes CVS All Kids Can, a program launched by CVS/Pharmacy Charitable Trust and CVS/Pharmacy designed to make life easier for children with special needs. CVS is America's largest retail pharmacy, operating more than 5,400 retail and specialty pharmacy stores in 36 states and the District of Columbia. Through this…
NASA Astrophysics Data System (ADS)
Aungwerojwit, A.; Gänsicke, B. T.; Rodríguez-Gil, P.; Hagen, H.-J.; Harlaftis, E. T.; Papadimitriou, C.; Lehto, H.; Araujo-Betancor, S.; Heber, U.; Fried, R. E.; Engels, D.; Katajainen, S.
2005-12-01
We present time-resolved optical spectroscopy and photometry of four relatively bright (V˜14.0-15.5) long-period cataclysmic variables (CVs) discovered in the Hamburg Quasar Survey: HS 0139+0559, HS 0229+8016, HS 0506+7725, and HS 0642+5049. Their respective orbital periods, 243.69±0.49 min, 232.550±0.049 min, 212.7±0.2 min, and 225.90±0.23 min are determined from radial velocity and photometric variability studies. HS 0506+7725 is characterised by strong Balmer and He emission lines, short-period (~10-20 min) flickering, and weak X-ray emission in the ROSAT All Sky Survey. The detection of a deep low state (B≃18.5) identifies HS 0506+7725 as a member of the VY Scl stars. HS 0139+0559, HS 0229+8016, and HS 0642+5049 display thick-disc like spectra and no or only weak flickering activity. HS 0139+0559 and HS 0229+8016 exhibit clean quasi-sinusoidal radial velocity variations of their emission lines but no or very little orbital photometric variability. In contrast, we detect no radial velocity variation in HS 0642+5049 but a noticeable orbital brightness variation. We identify all three systems either as UX UMa-type novalike variables or as Z Cam-type dwarf novae. Our identification of these four new systems underlines that the currently known sample of CVs is rather incomplete even for bright objects. The four new systems add to the clustering of orbital periods in the 3-4 h range found in the sample of HQS selected CVs, and we discuss the large incidence of magnetic CVs and VY Scl/SW Sex stars found in this period range among the known population of CVs.
A study of computer-related upper limb discomfort and computer vision syndrome.
Sen, A; Richardson, Stanley
2007-12-01
Personal computers are one of the commonest office tools in Malaysia today. Their usage, even for three hours per day, leads to a health risk of developing Occupational Overuse Syndrome (OOS), Computer Vision Syndrome (CVS), low back pain, tension headaches and psychosocial stress. The study was conducted to investigate how a multiethnic society in Malaysia is coping with these problems that are increasing at a phenomenal rate in the west. This study investigated computer usage, awareness of ergonomic modifications of computer furniture and peripherals, symptoms of CVS and risk of developing OOS. A cross-sectional questionnaire study of 136 computer users was conducted on a sample population of university students and office staff. A 'Modified Rapid Upper Limb Assessment (RULA) for office work' technique was used for evaluation of OOS. The prevalence of CVS was surveyed incorporating a 10-point scoring system for each of its various symptoms. It was found that many were using standard keyboard and mouse without any ergonomic modifications. Around 50% of those with some low back pain did not have an adjustable backrest. Many users had higher RULA scores of the wrist and neck suggesting increased risk of developing OOS, which needed further intervention. Many (64%) were using refractive corrections and still had high scores of CVS commonly including eye fatigue, headache and burning sensation. The increase of CVS scores (suggesting more subjective symptoms) correlated with increase in computer usage spells. It was concluded that further onsite studies are needed, to follow up this survey to decrease the risks of developing CVS and OOS amongst young computer users.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wong, O; Lo, G; Yuan, J
Purpose: There is growing interests in applying MR-simulator(MR-sim) in radiotherapy but MR images subject to hardware, patient and pulse sequence dependent geometric distortion that may potentially influence target definition. This study aimed to evaluate the influence on head-and-neck tissue delineation, in terms of positional and volumetric variability, of two T1-weighted(T1w) MR sequences on a 1.5T MR-sim Methods: Four healthy volunteers were scanned (4 scans for each on different days) using both spin-echo (3DCUBE, TR/TE=500/14ms, TA=183s) and gradient-echo sequences (3DFSPGR, TE/TR=7/4ms, TA=173s) with identical coverage, voxel-size(0.8×0.8×1.0mm3), receiver-bandwidth(62.5kHz/pix) and geometric correction on a 1.5T MR-sim immobilized with personalized thermoplastic cast and head-rest.more » Under this setting, similar T1w contrast and signal-to-noise ratio were obtained, and factors other than sequence that might bias image distortion and tissue delineation were minimized. VOIs of parotid gland(PGR, PGL), pituitary gland(PIT) and eyeballs(EyeL, EyeR) were carefully drawn, and inter-scan coefficient-of-variation(CV) of VOI centroid position and volume were calculated for each subject. Mean and standard deviation(SD) of the CVs for four subjects were compared between sequences using Wilcoxon ranksum test. Results: The mean positional(<4%) and volumetric(<7%) CVs varied between tissues, majorly dependent on tissue inherent properties like volume, location, mobility and deformability. Smaller mean volumetric CV was found in 3DCUBE, probably due to its less proneness to tissue susceptibility, but only PGL showed significant difference(P<0.05). Positional CVs had no significant differences for all VOIs(P>0.05) between sequences, suggesting volumetric variation might be more sensitive to sequence-dependent delineation difference. Conclusion: Although 3DCUBE is considered less prone to tissue susceptibility-induced artifact and distortion, our preliminary data showed that both sequences had insignificant differences on positional and volumetric CV in most head-and-neck tissues except for PGL. This study is majorly limited in its small sample size. Influences of image contrasts(T1w v.s. T2w) and inter-observer difference have to be further investigated.« less
NASA Astrophysics Data System (ADS)
Schwichow, Martin; Christoph, Simon; Boone, William J.; Härtig, Hendrik
2016-01-01
The so-called control-of-variables strategy (CVS) incorporates the important scientific reasoning skills of designing controlled experiments and interpreting experimental outcomes. As CVS is a prominent component of science standards appropriate assessment instruments are required to measure these scientific reasoning skills and to evaluate the impact of instruction on CVS development. A detailed review of existing CVS instruments suggests that they utilize different, and only a few of the four, critical CVS sub-skills in the item development. This study presents a new CVS assessment instrument (CVS Inventory, CVSI) and investigates the validity of student measures derived from this instrument utilizing Rasch analyses. The results indicate that the CVSI produces reliable and valid student measures with regard to CVS. Furthermore, the results show that the item difficulty depends on the CVS sub-skills utilized in item development, but not on the item content. Accordingly, previous instruments that are restricted to a few CVS sub-skills tend to over- or underestimate students' CVS skills. In addition, these results indicate that students are able to use CVS as a domain general strategy in multiple content areas. Consequences for science instruction and assessment are discussed.
Neural Network and Nearest Neighbor Algorithms for Enhancing Sampling of Molecular Dynamics.
Galvelis, Raimondas; Sugita, Yuji
2017-06-13
The free energy calculations of complex chemical and biological systems with molecular dynamics (MD) are inefficient due to multiple local minima separated by high-energy barriers. The minima can be escaped using an enhanced sampling method such as metadynamics, which apply bias (i.e., importance sampling) along a set of collective variables (CV), but the maximum number of CVs (or dimensions) is severely limited. We propose a high-dimensional bias potential method (NN2B) based on two machine learning algorithms: the nearest neighbor density estimator (NNDE) and the artificial neural network (ANN) for the bias potential approximation. The bias potential is constructed iteratively from short biased MD simulations accounting for correlation among CVs. Our method is capable of achieving ergodic sampling and calculating free energy of polypeptides with up to 8-dimensional bias potential.
40 CFR 1066.135 - Linearity verification.
Code of Federal Regulations, 2014 CFR
2014-07-01
... CVS, double-dilution, and partial-flow systems. (3) PM sample. (4) Chiller sample, for gaseous sampling systems that use thermal chillers to dry samples, and that use chiller temperature to calculate dewpoint at the chiller outlet. For testing, if you choose to use the high alarm temperature setpoint for...
Aziz, Imran; Palsson, Olafur S; Whitehead, William E; Sperber, Ami D; Simrén, Magnus; Törnblom, Hans
2018-05-29
Functional nausea and vomiting disorders (FNVDs) are classified as chronic nausea and vomiting syndrome (CNVS) or cyclic vomiting syndrome (CVS) - CVS includes cannabinoid hyperemesis syndrome. We investigated the population prevalence of FNVDs, their characteristics, and associated factors. In the year 2015, an Internet cross-sectional health survey was completed by 5931 adults in the general populations of 3 English-speaking countries; 2100 participants were in the United States, Canada, or the United Kingdom. Quota-based sampling was used to generate demographically balanced and population-representative samples. The survey collected data on demographics, healthcare visits, medications, somatic symptom severity, quality of life, and symptom-based diagnostic criteria for Rome IV FNVDs as well as for irritable bowel syndrome and functional dyspepsia. Subsequent comparisons were made between Rome IV FNVD subjects and individuals without FNVDs (controls). Overall, 2.2% of the population (n=131) fulfilled symptom-based diagnostic criteria for Rome IV FNVDs - the United States (3%) had a greater prevalence than Canada (1.9%) or the United Kingdom (1.8%) (P=.02). The prevalence of CNVS was similar among the countries, ranging from 0.8% to 1.2%. However, the prevalence of CVS was higher in the United States (2%) than in Canada (0.7%) or the United Kingdom (1%) (P=.03). The proportion of subjects with CVS taking cannabis did not differ significantly among countries (P=.31), although the 7 cases of cannabinoid hyperemesis syndrome were in the United States. A significantly higher proportion of subjects with CVS reported a compulsive need for hot water bathing to alleviate emetic symptoms than subjects with CNVS (44% vs. 19%, P=.03); this behaviour was independent of cannabis but augmented by its use. Subjects with FNVDs had significantly greater health impairment and health care utilization than controls. On multivariate analysis, independent factors associated with FNVDs were younger age, increasing somatic symptom severity, lower quality of life, presence of irritable bowel syndrome, and functional dyspepsia. However, on subgroup analysis, somatic symptom severity was associated with CVS but not CNVS, whereas poor quality of life was associated with CNVS but not CVS. Based on a cross-sectional health survey of adults in the general populations of 3 English-speaking countries, approximately 2% of subjects meet symptom-based criteria for Rome IV FNVDs and have considerable health impairments. Hot water bathing to alleviate emetic symptoms is reported for all FNVDs, and is perpetuated by cannabis use. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.
40 CFR 86.1509 - Exhaust gas sampling system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Exhaust gas sampling system. 86.1509... Procedures § 86.1509 Exhaust gas sampling system. (a) The exhaust gas sampling system shall transport the... sample (i.e., water removed) to the analysis system. (c) A CVS sampling system with bag or continuous...
40 CFR 91.420 - CVS concept of exhaust gas sampling system.
Code of Federal Regulations, 2013 CFR
2013-07-01
... that complete mixing of the engine exhaust and background air is assured prior to the sampling probe.... The background probe must draw a representative sample of the background air during each sampling mode...) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe, this system...
40 CFR 90.420 - CVS concept of exhaust gas sampling system.
Code of Federal Regulations, 2013 CFR
2013-07-01
... sampling probe. (2) Exhaust flow metering system. A dilute exhaust flow metering system must be used to... exhaust. The background probe must draw a representative sample of the background air during each sampling... (bag) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe...
40 CFR 91.420 - CVS concept of exhaust gas sampling system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... that complete mixing of the engine exhaust and background air is assured prior to the sampling probe.... The background probe must draw a representative sample of the background air during each sampling mode...) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe, this system...
40 CFR 90.420 - CVS concept of exhaust gas sampling system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... sampling probe. (2) Exhaust flow metering system. A dilute exhaust flow metering system must be used to... exhaust. The background probe must draw a representative sample of the background air during each sampling... (bag) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe...
40 CFR 90.420 - CVS concept of exhaust gas sampling system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... sampling probe. (2) Exhaust flow metering system. A dilute exhaust flow metering system must be used to... exhaust. The background probe must draw a representative sample of the background air during each sampling... (bag) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe...
40 CFR 90.420 - CVS concept of exhaust gas sampling system.
Code of Federal Regulations, 2012 CFR
2012-07-01
... sampling probe. (2) Exhaust flow metering system. A dilute exhaust flow metering system must be used to... exhaust. The background probe must draw a representative sample of the background air during each sampling... (bag) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe...
40 CFR 90.420 - CVS concept of exhaust gas sampling system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... sampling probe. (2) Exhaust flow metering system. A dilute exhaust flow metering system must be used to... exhaust. The background probe must draw a representative sample of the background air during each sampling... (bag) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe...
40 CFR 91.420 - CVS concept of exhaust gas sampling system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... that complete mixing of the engine exhaust and background air is assured prior to the sampling probe.... The background probe must draw a representative sample of the background air during each sampling mode...) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe, this system...
40 CFR 91.420 - CVS concept of exhaust gas sampling system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... that complete mixing of the engine exhaust and background air is assured prior to the sampling probe.... The background probe must draw a representative sample of the background air during each sampling mode...) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe, this system...
40 CFR 91.420 - CVS concept of exhaust gas sampling system.
Code of Federal Regulations, 2012 CFR
2012-07-01
... that complete mixing of the engine exhaust and background air is assured prior to the sampling probe.... The background probe must draw a representative sample of the background air during each sampling mode...) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe, this system...
NASA Astrophysics Data System (ADS)
Lai, Xiaoming; Zhu, Qing; Zhou, Zhiwen; Liao, Kaihua
2017-12-01
In this study, seven random combination sampling strategies were applied to investigate the uncertainties in estimating the hillslope mean soil water content (SWC) and correlation coefficients between the SWC and soil/terrain properties on a tea + bamboo hillslope. One of the sampling strategies is the global random sampling and the other six are the stratified random sampling on the top, middle, toe, top + mid, top + toe and mid + toe slope positions. When each sampling strategy was applied, sample sizes were gradually reduced and each sampling size contained 3000 replicates. Under each sampling size of each sampling strategy, the relative errors (REs) and coefficients of variation (CVs) of the estimated hillslope mean SWC and correlation coefficients between the SWC and soil/terrain properties were calculated to quantify the accuracy and uncertainty. The results showed that the uncertainty of the estimations decreased as the sampling size increasing. However, larger sample sizes were required to reduce the uncertainty in correlation coefficient estimation than in hillslope mean SWC estimation. Under global random sampling, 12 randomly sampled sites on this hillslope were adequate to estimate the hillslope mean SWC with RE and CV ≤10%. However, at least 72 randomly sampled sites were needed to ensure the estimated correlation coefficients with REs and CVs ≤10%. Comparing with all sampling strategies, reducing sampling sites on the middle slope had the least influence on the estimation of hillslope mean SWC and correlation coefficients. Under this strategy, 60 sites (10 on the middle slope and 50 on the top and toe slopes) were enough to ensure the estimated correlation coefficients with REs and CVs ≤10%. This suggested that when designing the SWC sampling, the proportion of sites on the middle slope can be reduced to 16.7% of the total number of sites. Findings of this study will be useful for the optimal SWC sampling design.
Central Venous Occlusion in the Hemodialysis Patient.
Krishna, Vinay Narasimha; Eason, Joseph B; Allon, Michael
2016-11-01
Central venous stenosis (CVS) is encountered frequently among hemodialysis patients. Prior ipsilateral central venous catheterization and cardiac rhythm device insertions are common risk factors, but CVS can also occur in the absence of this history. Chronic CVS can cause thrombosis with partial or complete occlusion of the central vein at the site of stenosis. CVS is frequently asymptomatic and identified as an incidental finding during imaging studies. Symptomatic CVS presents most commonly as an upper- or lower-extremity edema ipsilateral to the CVS. Previously unsuspected CVS may become symptomatic after placement of an ipsilateral vascular access. The likelihood of symptomatic CVS may be affected by the central venous catheter (CVC) location; CVC side; duration of CVC dependence; type, location, and blood flow of the ipsilateral access; and extent of collateral veins. Venous angiography is the gold standard for diagnosis. Percutaneous transluminal angioplasty and stent placement can improve the stenosis and alleviate symptoms, but CVS typically recurs frequently, requiring repeated interventions. Refractory symptomatic CVS may require ligation of the ipsilateral vascular access. Because no available treatment option is curative, the goal should be to prevent CVS by minimizing catheters and central vein instrumentation in patients with chronic kidney disease and dialysis patients. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
The space density of post-period minimum Cataclysmic Variables
NASA Astrophysics Data System (ADS)
Hernández Santisteban, J. V.; Knigge, C.; Pretorius, M. L.; Sullivan, M.; Warner, B.
2018-01-01
Binary evolution theory predicts that accreting white dwarfs with substellar companions dominate the Galactic population of cataclysmic variables (CVs). In order to test these predictions, it is necessary to identify these systems, which may be difficult if the signatures of accretion become too weak to be detected. The only chance to identify such 'dead' CVs is by exploiting their close binary nature. We have therefore searched the Sloan Digital Sky Survey (SDSS) Stripe 82 area for apparently isolated white dwarfs that undergo eclipses by a dark companion. We found no such eclipses in either the SDSS or Palomar Transient Factory data sets among our sample of 2264 photometrically selected white dwarf candidates within Stripe 82. This null result allows us to set a firm upper limit on the space density, ρ0, of dead CVs. In order to determine this limit, we have used Monte Carlo simulations to fold our selection criteria through a simple model of the Galactic CV distribution. Assuming a TWD = 7500 K, the resulting 2σ limit on the space density of dead CVs is ρ0 ≲ 2 × 10-5 pc-3, where TWD is the typical effective temperature of the white dwarf in such systems.
ASSOCIATION BETWEEN DENTAL AND SKELETAL MATURATION STAGES IN CROATIAN SUBJECTS.
Srkoc, Tamara; Mestrović, Senka; Anić-Milosević, Sandra; Slaj, Mladen
2015-12-01
This study investigated the relationships between the stages of calcification of teeth and cervical vertebral maturation. The sample consisted of 295 subjects (129 male and 166 female), mean age 13.36 ± 2.65 (range 7-18) years. Dental age was evaluated from panoramic radiographs according to the method of Demirjian. Cervical vertebral maturation was determined on lateral cephalometric radiographs using cervical vertebrae maturation stages (CVS). For assessing the relationship between cervical vertebral and dental maturation, percentage distributions of the stages of calcification for each studied tooth were calculated. Only in the first CVS stage, boys and girls were of the same age. In all other stages (CVS 2-CVS 6) girls were by 0.98 (range 0.23-1.86) younger than boys. Gender differences in the mineralization pattern were also observed. It was found that dental maturation was finished earlier in female subjects. The highest correlation coefficient between dental and skeletal maturity was found for second premolars. Mineralization pattern of second premolars could be considered as a guideline for prediction of the pubertal growth spurt. Dental maturation stages might be clinically useful as a reliable indicator of facial growth.
NASA Astrophysics Data System (ADS)
Giorgino, Toni
2018-07-01
The proper choice of collective variables (CVs) is central to biased-sampling free energy reconstruction methods in molecular dynamics simulations. The PLUMED 2 library, for instance, provides several sophisticated CV choices, implemented in a C++ framework; however, developing new CVs is still time consuming due to the need to provide code for the analytical derivatives of all functions with respect to atomic coordinates. We present two solutions to this problem, namely (a) symbolic differentiation and code generation, and (b) automatic code differentiation, in both cases leveraging open-source libraries (SymPy and Stan Math, respectively). The two approaches are demonstrated and discussed in detail implementing a realistic example CV, the local radius of curvature of a polymer. Users may use the code as a template to streamline the implementation of their own CVs using high-level constructs and automatic gradient computation.
Grati, Francesca R; Malvestiti, Francesca; Grimi, Beatrice; Gaetani, Elisa; Di Meco, Anna Maria; Trotta, Anna; Liuti, Rosaria; Chinetti, Sara; Dulcetti, Francesca; Ruggeri, Anna Maria; Agrati, Cristina; Frascoli, Giuditta; Milani, Silvia; De Toffol, Simona; Martinoni, Lorenza; Paganini, Silvia; Marcato, Livia; Maggi, Federico; Simoni, Giuseppe
2013-05-01
Karyotyping on chorionic villous samples (CVS) includes the analysis of both cytotrophoblast (STC) and mesenchyme (LTC). This approach requires complex laboratory organization and trained technicians. The introduction of quantitative fluorescent polymerase chain reaction (QF-PCR) instead of conventional karyotyping in low-risk pregnancies opened its application in CVS analysis. Discordant QF-PCR and CVS cytogenetic results were reported, and strategies for CVS analysis were introduced to minimize this risk. The possibility to substitute the STC with QF-PCR was reported. The aim of this study is to evaluate benefits and limitations of the approach QF-PCR + LTC compared with the traditional method STC + LTC and to quantify the associated risks of false results. This study is based on a retrospective cytogenetic audit of CVS results (n = 44 727) generated by the STC + LTC analytic approach. False-negative risks related to true fetal mosaicism type IV, imprinting syndromes and maternal contamination in LTC were calculated. Compared with STC + LTC, QF-PCR + LTC approach is associated with a cumulative false-negative risk of ~1/3100-1/4400. Costs and reporting time of STC in a high-throughput cytogenetic lab are similar to a CE-IVD marked QF-PCR analysis. These results should be clearly highlighted in the pre-test counseling and extensively discussed with the couple prior to testing for informed consent. © 2013 John Wiley & Sons, Ltd.
Impact of CVS Pharmacy's Discontinuance of Tobacco Sales on Cigarette Purchasing (2012-2014).
Polinski, Jennifer M; Howell, Benjamin; Gagnon, Michael A; Kymes, Steven M; Brennan, Troyen A; Shrank, William H
2017-04-01
To assess the impact of CVS Health's discontinuation of tobacco sales on cigarette purchasing. We used households' purchasing data to assess rates at which households stopped cigarette purchasing for at least 6 months during September 2014 to August 2015 among 3 baseline groups: CVS-exclusive cigarette purchasers, CVS+ (CVS and other retailers), and other-exclusive (only non-CVS retailers). In state-level analyses using retailers' point-of-sale purchase data, an interrupted time series compared cigarette purchasing before (January 2012 to August 2014) and after (September 2014 to April 2015) tobacco removal in 13 intervention states with CVS market share of at least 15% versus 3 control states with no CVS stores. Compared with other-exclusive purchasers, CVS-exclusive purchasers were 38% likelier (95% confidence interval = 1.06, 1.81) to stop cigarette purchasing after tobacco removal. Compared with control states, intervention states had a significant mean decrease of 0.14 (95% confidence interval = 0.06, 0.22) in packs per smoker per month. After CVS's tobacco removal, household- and population-level cigarette purchasing declined significantly. Private retailers can play a meaningful role in restricting access to tobacco. This highlights one approach to reducing tobacco use and improving public health.
Morimoto, Kinjiro; Hooper, D. Craig; Spitsin, Sergei; Koprowski, Hilary; Dietzschold, Bernhard
1999-01-01
The mouse-adapted rabies virus strain CVS-24 has stable variants, CVS-B2c and CVS-N2c, which differ greatly in their pathogenicity for normal adult mice and in their ability to infect nonneuronal cells. The glycoprotein (G protein), which has previously been implicated in rabies virus pathogenicity, shows substantial structural differences between these variants. Although prior studies have identified antigenic site III of the G protein as the major pathogenicity determinant, CVS-B2c and CVS-N2c do not vary at this site. The possibility that pathogenicity is inversely related to G protein expression levels is suggested by the finding that CVS-B2c, the less pathogenic variant, expresses at least fourfold-higher levels of G protein than CVS-N2c in infected neurons. Although there is some difference between CVS-B2c- and CVS-N2c-infected neurons in G protein mRNA expression levels, the differential expression of G protein appears to be largely determined by posttranslational mechanisms that affect G protein stability. Pulse-chase experiments indicated that the G protein of CVS-B2c is degraded more slowly than that of CVS-N2c. The accumulation of G protein correlated with the induction of programmed cell death in CVS-B2c-infected neurons. The extent of apoptosis was considerably lower in CVS-N2c-infected neurons, where G protein expression was minimal. While nucleoprotein (N protein) expression levels were similar in neurons infected with either variant, the transport of N protein into neuronal processes was strongly inhibited in CVS-B2c-infected cells. Thus, downregulation of G protein expression in neuronal cells evidently contributes to rabies virus pathogenesis by preventing apoptosis and the apparently associated failure of the axonal transport of N protein. PMID:9847357
Central vein stenosis: current concepts.
Agarwal, Anil K
2009-09-01
Central vein stenosis (CVS) is a common complication of the central venous catheter (CVC) placement. The prevalence of CVS has mostly been studied in those who present with symptoms such as swelling of the extremity, neck and breast. CVS compromises arteriovenous access and can be resistant to treatment. A previous history of CVC placement is the most important risk factor for the development of CVS later. Pacemaker and defibrillator wires are associated with a high incidence of CVS. Increasingly liberal use of peripherally inserted central catheters (PICC) is likely to increase the incidence of CVS. The trauma and inflammation related to the catheter placement is thought to result in microthrombi formation, intimal hyperplasia and fibrotic response, with development of CVS. Treatment of CVS by endovascular procedures involves angioplasty of the stenosis. An elastic or recurrent stenosis may require a stent placement. The long-term benefits of the endovascular procedures, although improved with newer technology, remain modest. Surgical options are usually limited. Future studies to explore the pathogenesis and the use of novel therapies to prevent and treat CVS are needed. The key to reducing the prevalence of CVS is in reducing CVC placement and placement of arteriovenous accesses prior to initiating dialysis. Early referral of the patients to the nephrologists by the primary care physicians is important. Timely vein mapping and referral to the surgeon for fistula creation can obviate the need for a CVC and decrease incidence of CVS.
Koren, Lee; Ng, Ella S M; Soma, Kiran K; Wynne-Edwards, Katherine E
2012-01-01
Blood samples from wild mammals and birds are often limited in volume, allowing researchers to quantify only one or two steroids from a single sample by immunoassays. In addition, wildlife serum or plasma samples are often lipemic, necessitating stringent sample preparation. Here, we validated sample preparation for simultaneous liquid chromatography--tandem mass spectrometry (LC-MS/MS) quantitation of cortisol, corticosterone, 11-deoxycortisol, dehydroepiandrosterone (DHEA), 17β-estradiol, progesterone, 17α-hydroxyprogesterone and testosterone from diverse mammalian (7 species) and avian (5 species) samples. Using 100 µL of serum or plasma, we quantified (signal-to-noise (S/N) ratio ≥ 10) 4-7 steroids depending on the species and sample, without derivatization. Steroids were extracted from serum or plasma using automated solid-phase extraction where samples were loaded onto C18 columns, washed with water and hexane, and then eluted with ethyl acetate. Quantitation by LC-MS/MS was done in positive ion, multiple reaction-monitoring (MRM) mode with an atmospheric pressure chemical ionization (APCI) source and heated nebulizer (500°C). Deuterated steroids served as internal standards and run time was 15 minutes. Extraction recoveries were 87-101% for the 8 analytes, and all intra- and inter-run CVs were ≤ 8.25%. This quantitation method yields good recoveries with variable lipid-content samples, avoids antibody cross-reactivity issues, and delivers results for multiple steroids. Thus, this method can enrich datasets by providing simultaneous quantitation of multiple steroids, and allow researchers to reimagine the hypotheses that could be tested with their volume-limited, lipemic, wildlife samples.
Milestone-compatible neurology resident assessments: A role for observable practice activities.
Jones, Lyell K; Dimberg, Elliot L; Boes, Christopher J; Eggers, Scott D Z; Dodick, David W; Cutsforth-Gregory, Jeremy K; Leep Hunderfund, Andrea N; Capobianco, David J
2015-06-02
Beginning in 2014, US neurology residency programs were required to report each trainee's educational progression within 29 neurology Milestone competency domains. Trainee assessment systems will need to be adapted to inform these requirements. The primary aims of this study were to validate neurology resident assessment content using observable practice activities (OPAs) and to develop assessment formats easily translated to the Neurology Milestones. A modified Delphi technique was used to establish consensus perceptions of importance of 73 neurology OPAs among neurology educators and trainees at 3 neurology residency programs. A content validity score (CVS) was derived for each neurology OPA, with scores ≥4.0 determined in advance to indicate sufficient content validity. The mean CVS for all OPAs was 4.4 (range 3.5-5.0). Fifty-seven (78%) OPAs had a CVS ≥4.0, leaving 16 (22%) below the pre-established threshold for content validity. Trainees assigned a higher importance to individual OPAs (mean CVS 4.6) compared to faculty (mean 4.4, p = 0.016), but the effect size was small (η(2) = 0.10). There was no demonstrated effect of length of education experience on perceived importance of neurology OPAs (p = 0.23). Two sample resident assessment formats were developed, one using neurology OPAs alone and another using a combination of neurology OPAs and the Neurology Milestones. This study provides neurology training programs with content validity evidence for items to include in resident assessments, and sample assessment formats that directly translate to the Neurology Milestones. Length of education experience has little effect on perceptions of neurology OPA importance. © 2015 American Academy of Neurology.
Exploratory Spectroscopy of Magnetic Cataclysmic Variables Candidates and Other Variable Objects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oliveira, A. S.; Palhares, M. S.; Rodrigues, C. V.
2017-04-01
The increasing number of synoptic surveys made by small robotic telescopes, such as the photometric Catalina Real-Time Transient Survey (CRTS), provides a unique opportunity to discover variable sources and improves the statistical samples of such classes of objects. Our goal is the discovery of magnetic Cataclysmic Variables (mCVs). These are rare objects that probe interesting accretion scenarios controlled by the white-dwarf magnetic field. In particular, improved statistics of mCVs would help to address open questions on their formation and evolution. We performed an optical spectroscopy survey to search for signatures of magnetic accretion in 45 variable objects selected mostly from themore » CRTS. In this sample, we found 32 CVs, 22 being mCV candidates, 13 of which were previously unreported as such. If the proposed classifications are confirmed, it would represent an increase of 4% in the number of known polars and 12% in the number of known IPs. A fraction of our initial sample was classified as extragalactic sources or other types of variable stars by the inspection of the identification spectra. Despite the inherent complexity in identifying a source as an mCV, variability-based selection, followed by spectroscopic snapshot observations, has proved to be an efficient strategy for their discoveries, being a relatively inexpensive approach in terms of telescope time.« less
Unconstrained Enhanced Sampling for Free Energy Calculations of Biomolecules: A Review
Miao, Yinglong; McCammon, J. Andrew
2016-01-01
Free energy calculations are central to understanding the structure, dynamics and function of biomolecules. Yet insufficient sampling of biomolecular configurations is often regarded as one of the main sources of error. Many enhanced sampling techniques have been developed to address this issue. Notably, enhanced sampling methods based on biasing collective variables (CVs), including the widely used umbrella sampling, adaptive biasing force and metadynamics, have been discussed in a recent excellent review (Abrams and Bussi, Entropy, 2014). Here, we aim to review enhanced sampling methods that do not require predefined system-dependent CVs for biomolecular simulations and as such do not suffer from the hidden energy barrier problem as encountered in the CV-biasing methods. These methods include, but are not limited to, replica exchange/parallel tempering, self-guided molecular/Langevin dynamics, essential energy space random walk and accelerated molecular dynamics. While it is overwhelming to describe all details of each method, we provide a summary of the methods along with the applications and offer our perspectives. We conclude with challenges and prospects of the unconstrained enhanced sampling methods for accurate biomolecular free energy calculations. PMID:27453631
Unconstrained Enhanced Sampling for Free Energy Calculations of Biomolecules: A Review.
Miao, Yinglong; McCammon, J Andrew
Free energy calculations are central to understanding the structure, dynamics and function of biomolecules. Yet insufficient sampling of biomolecular configurations is often regarded as one of the main sources of error. Many enhanced sampling techniques have been developed to address this issue. Notably, enhanced sampling methods based on biasing collective variables (CVs), including the widely used umbrella sampling, adaptive biasing force and metadynamics, have been discussed in a recent excellent review (Abrams and Bussi, Entropy, 2014). Here, we aim to review enhanced sampling methods that do not require predefined system-dependent CVs for biomolecular simulations and as such do not suffer from the hidden energy barrier problem as encountered in the CV-biasing methods. These methods include, but are not limited to, replica exchange/parallel tempering, self-guided molecular/Langevin dynamics, essential energy space random walk and accelerated molecular dynamics. While it is overwhelming to describe all details of each method, we provide a summary of the methods along with the applications and offer our perspectives. We conclude with challenges and prospects of the unconstrained enhanced sampling methods for accurate biomolecular free energy calculations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... concentration and total flow over the test period. (2) Vehicle tailpipe to CVS Duct. For methanol-fueled... proportional samples for the bag sample, and for methanol-fueled vehicles, the methanol sample (Figure B94-2... methanol-fueled vehicles, the sample lines for the methanol and formaldehyde samples are heated to prevent...
Do third-party plans really pay for CVS care?
Soden, Richard
2002-04-01
Until specific CPT and ICD-9 codes are created and approved for CVS, and until there is uniform agreement that CVS is a true medical anomaly (or not), each practitioner will have to decide on how to bill for the signs and symptoms of Computer Vision Syndrome. If the practitioner chooses to view CVS as a medical problem, then the same guidelines and rules for all other patients should be followed with appropriate documentation using CPT and ICD-9 coding. If the practitioner chooses to consider CVS solely as an optical problem, this is a "noncovered" service and the patient or any applicable optical plan will be responsible for payment. One final note: each practitioner who tests for CVS will also have to determine if there is a separate fee for CVS testing. If the practitioner considers CVS to be a medical problem, it may be applicable to include testing for Computer Vision Syndrome as an incidental test to the medical office visit. If the practitioner chooses to consider CVS to be purely an optical problem, it may be appropriate to add an appropriate charge to the noncovered examination. Whatever the decision is, there must be consistency from patient to patient.
Attitudes about abortion of women who undergo prenatal diagnosis.
Kolker, A; Burke, B M; Phillips, J U
1991-01-01
Data on 120 women who had experienced either amniocentesis or chorionic villus sampling (CVS) and were attending clinics serving women in the Washington, D.C. area or in the San Diego, California area were analyzed to examine their attitudes toward abortion. In-depth, open-ended interviews were also conducted with 24 currently or recently pregnant women who had also undergone a prenatal diagnostic procedure. All the women wanted the pregnancy in question, and all were more wealthy and better educated than the average woman in the US. Yet women who underwent CVS were better educated (completed college, 89.1% vs. 57.2%) and were more affluent (mean household income, $56,000 vs. $46,000) than those who underwent amniocentesis. Women who had CVS encountered difficulties with obtaining access to CVS and, if it were not for their own initiative, they would have not been able to undergo CVS. This emphasized that, due to more economic, educational, or informational resources, they had greater access to prenatal care. It also verified earlier studies identifying a correlation between adoption of innovations and individual resources. 39.5% of CVS users had earlier elected to terminate a previous pregnancy compared with 22.4% of amniocentesis users. Most respondents supported women's freedom of choice to abort a pregnancy for reasons of endangerment to a mother's health (100% for general population, 98.1% for self), rape or incest (98.2% vs. 97.2%), fetal abnormality (99.1% vs. 100%), low income (86.7% vs. 61.2%), and desire to have no more children (81.3%-88.5% vs. 52.5%-74.5%). Yet few women (19.2% vs. 5.3%) approved of abortion based on sex of the fetus. Even though the respondents were committed to abortion rights, they tended to find it personally hard, if not impossible, to terminate a pregnancy now. They spent considerable emotional and financial resources toward the wanted pregnancy, but, by choosing to undergo prenatal diagnosis, were willing to face the possibility of losing the pregnancy.
Gil, M M; Giunta, G; Macalli, E A; Poon, L C; Nicolaides, K H
2015-01-01
This study reports on the clinical implementation of cell-free DNA (cfDNA) testing, contingent on the results of the combined test, in screening for fetal trisomies 21, 18 and 13 in two UK National Health Service hospitals. Women with a combined-test risk of ≥ 1:100 (high risk) were offered the options of chorionic villus sampling (CVS), cfDNA testing or no further testing and those with a risk of 1:101 to 1:2500 (intermediate risk) were offered cfDNA or no further testing. The objective of the study was to examine the factors affecting patient decisions concerning their options. Combined screening was performed in 6651 singleton pregnancies in which the risk for trisomies was high in 260 (3.9%), intermediate in 2017 (30.3%) and low in 4374 (65.8%). Logistic regression analysis was used to determine which factors among maternal characteristics, fetal nuchal translucency thickness (NT) and risk for trisomies were significant predictors of opting for CVS in the high-risk group and opting for cfDNA testing in the intermediate-risk group. In the high-risk group, 104 (40.0%) women opted for CVS; predictors for CVS were increasing fetal NT and increasing risk for trisomies, while the predictor against CVS was being of Afro-Caribbean racial origin (r = 0.366). In the intermediate-risk group, 1850 (91.7%) women opted for cfDNA testing; predictors for cfDNA testing were increasing maternal age, increasing risk for trisomies and university education, while predictors against cfDNA testing were being of Afro-Caribbean racial origin, smoking and being parous (r = 0.105). This study has identified factors that can influence the decision of women undergoing combined screening in favor of or against CVS and in favor of or against cfDNA testing. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Geoffroy, Olivier; Boust, Nicolas; Chazal, Hervé; Flury, Sébastien; Roudet, James
2018-04-01
This article focuses on the modeling of the hysteresis loop featured by Fe-Cu-Nb-Si-B nanocrystalline alloys with transverse induced anisotropy. The magnetization reversal process of a magnetic correlated volume (CV), characterized by the induced anisotropy Ku, and a deviation of the local easy magnetization direction featuring the effect of a local incoherent anisotropy Ki, is analyzed, taking account of magnetostatic interactions. Solving the equations shows that considering a unique typical kind of CV does not enable accounting for both the domain pattern and the coercivity. Actually, the classical majority CVs obeying the random anisotropy model explains well the domain pattern but considering another kind of CVs, minority, mingled with classical ones, featuring a magnitude of Ki comparable to Ku, is necessary to account for coercivity. The model has been successfully compared with experimental data.
[Cervical vertebrae: Mandibular growth dynamism indicators?].
Raberin, Monique; Cozor, Ilinca; Gobert-Jacquart, Stéphanie
2012-03-01
A study of mandibular growth maturation was performed on a population of 103 patients during orthodontic treatment (69 girls and 34 boys) from 11 to 16 years, having initially a Class II skeletal discrepancy. The relationship between wrist maturation indices and the cervical vertebrae maturation was studied by Lamparski classification. Significant correlations were found between Björk stages, MP3=, MP3 cap and MP3 U and respectively Lamparski stages as CVS 2, CVS 3-4 and CVS 5-6. This retrospective longitudinal study identified three mandibular variables at three different maturation stages according to Björk classification and to the six stages of Lamparski classification. The relationships between these different maturation stages and a quantitative mandibular response permit to estimate optimal time for our orthodontic therapy. The results indicate a significant increase in mandibular length between CVS 4 and CVS 5, suggesting the persistence of a condylar response to a stimulation therapy after CVS3 or CVS 4 stages (MP3 cap). Mandibular growth seems to continue after MP3 U stage or CVS 5 stage. © EDP Sciences, SFODF, 2012.
Başaran, Ahmet; Başaran, Mustafa; Topatan, Betül; Martin, James N
2016-01-01
To perform a meta-analysis for an assessment of the risk of preeclampsia or gestational hypertension following chorionic villus sampling (CVS). PubMed was systematically searched from its inception through January 2016. Nine reports were identified. A pre-specified scale was used to assess their quality. We performed pooling into three subgroups with respect to the control group: A) Patients with no invasive prenatal diagnostic procedure served as a control group for comparison. The odds ratios for gestational hypertension (0.76, 95% CI 0.46-1.26), preeclampsia (0.83, 95% CI 0.42-1.67), and severe preeclampsia (0.49, 95% CI 0.04-5.78) or when hypertension categories were pooled (0.80, 95% CI 0.46-1.41) were not significantly different. B) Patients with midtrimester diagnostic amniocentesis and patients with no invasive prenatal diagnostic procedure were combined as a control group for comparison. The odds ratios for preeclampsia (1, 95% CI 0.46-2.18), severe preeclampsia (0.83, 95% CI 0.14-4.85), and pooled hypertension categories (1.07, 95% CI 0.63-1.84) were not significantly different. C) Patients with midtrimester diagnostic amniocentesis served as a control group. There was a significant difference in the odds ratio for preeclampsia between the CVS and amniocentesis groups (2.47, 95% CI 1.14-5.33). There was a marginal difference in the odds ratio for combined pregnancy-induced hypertension categories between the CVS and amniocentesis groups (1.61, 95% CI 1.02-2.53). The available data do not indicate an increased risk of preeclampsia or gestational hypertension following first trimester CVS. The heterogeneity and retrospective design of existing studies are limiting factors for our analysis and findings.
Effect of contact lens use on Computer Vision Syndrome.
Tauste, Ana; Ronda, Elena; Molina, María-José; Seguí, Mar
2016-03-01
To analyse the relationship between Computer Vision Syndrome (CVS) in computer workers and contact lens use, according to lens materials. Cross-sectional study. The study included 426 civil-service office workers, of whom 22% were contact lens wearers. Workers completed the Computer Vision Syndrome Questionnaire (CVS-Q) and provided information on their contact lenses and exposure to video display terminals (VDT) at work. CVS was defined as a CVS-Q score of 6 or more. The covariates were age and sex. Logistic regression was used to calculate the association (crude and adjusted for age and sex) between CVS and individual and work-related factors, and between CVS and contact lens type. Contact lens wearers are more likely to suffer CVS than non-lens wearers, with a prevalence of 65% vs 50%. Workers who wear contact lenses and are exposed to the computer for more than 6 h day(-1) are more likely to suffer CVS than non-lens wearers working at the computer for the same amount of time (aOR = 4.85; 95% CI, 1.25-18.80; p = 0.02). Regular contact lens use increases CVS after 6 h of computer work. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.
Cyclic Vomiting Syndrome in 41 adults: the illness, the patients, and problems of management
Fleisher, David R; Gornowicz, Blake; Adams, Kathleen; Burch, Richard; Feldman, Edward J
2005-01-01
Background Cyclic Vomiting Syndrome (CVS) is a disorder characterized by recurrent, stereotypic episodes of incapacitating nausea, vomiting and other symptoms, separated by intervals of comparative wellness. This report describes the clinical features, co-morbidities and problems encountered in management of 41 adult patients who met the diagnostic criteria for CVS. Methods This is a retrospective study of adults with CVS seen between 1994 and 2003. Follow-up data were obtained by mailed questionnaires. Results Age of onset ranged from 2 to 49 years. The duration of CVS at the time of consultation ranged from less than 1 year to 49 years. CVS episodes were stereotypic in respect of their hours of onset, symptomatology and length. Ninety-three percent of patients had recognizable prodromes. Half of the patients experienced a constellation of symptoms consisting of CVS episodes, migraine diathesis, inter-episodic dyspeptic nausea and a history of panic attacks. Deterioration in the course of CVS is indicated by coalescence of episodes in time. The prognosis of CVS is favorable in the majority of patients. Conclusion CVS is a disabling disorder affecting adults as well as children. Because its occurrence in adults is little known, patients experience delayed or mis-diagnosis and ineffectual, sometimes inappropriately invasive management. PMID:16368014
Hill, Benjamin David; Womble, Melissa N; Rohling, Martin L
2015-01-01
This study utilized logistic regression to determine whether performance patterns on Concussion Vital Signs (CVS) could differentiate known groups with either genuine or feigned performance. For the embedded measure development group (n = 174), clinical patients and undergraduate students categorized as feigning obtained significantly lower scores on the overall test battery mean for the CVS, Shipley-2 composite score, and California Verbal Learning Test-Second Edition subtests than did genuinely performing individuals. The final full model of 3 predictor variables (Verbal Memory immediate hits, Verbal Memory immediate correct passes, and Stroop Test complex reaction time correct) was significant and correctly classified individuals in their known group 83% of the time (sensitivity = .65; specificity = .97) in a mixed sample of young-adult clinical cases and simulators. The CVS logistic regression function was applied to a separate undergraduate college group (n = 378) that was asked to perform genuinely and identified 5% as having possibly feigned performance indicating a low false-positive rate. The failure rate was 11% and 16% at baseline cognitive testing in samples of high school and college athletes, respectively. These findings have particular relevance given the increasing use of computerized test batteries for baseline cognitive testing and return-to-play decisions after concussion.
Chorionic Villus Sampling (CVS)
... Careers Archives Health Topics Pregnancy Before or between pregnancies Nutrition, weight & fitness Prenatal care Is it safe? Labor & ... Report Cards Careers Archives Pregnancy Before or between pregnancies Nutrition, weight & fitness Prenatal care Is it safe? Labor & ...
De Jong, TR; Harris, BN; Perea-Rodriguez, JP; Saltzman, W
2013-01-01
Social environment and parental state affect stress responses in mammals, but their impact may depend on the social and reproductive strategy of the species. The influences of cohabitation with a male or female conspecific, and the birth of offspring, on the physiological and endocrine responses to chronic variable stress were studied in the monogamous and biparental California mouse (Peromyscus californicus). Adult male California mice were housed either with a male cage mate (virgin males, VM), a female cage mate (pair-bonded males, PBM), or a female cage mate and their first newborn litter (new fathers, NF). VM, PBM and NF underwent a 7-day chronic variable stress paradigm (CVS, three stressors per day at semi-random times, n=7-8 per housing condition). Compared to control males (CON, n=6-7 per housing condition), CVS caused loss of body mass, increased basal plasma corticosterone concentrations, and increased basal expression of arginine vasopressin (AVP) mRNA in the paraventricular nucleus of the hypothalamus (PVN). These effects were independent of housing condition. Neither CVS nor housing condition altered novel-stressor-induced corticosterone release, spleen or testis mass, or basal expression of corticotropin-releasing hormone (CRH) mRNA in the PVN. Although CVS appeared to increase adrenal mass and reduce thymus mass specifically in NF, these effects were explained by the lower adrenal mass and higher thymus mass of NF compared to PBM and VM under control conditions. These results suggest that neither engaging in a pair bond nor becoming a father attenuates typical responses to CVS, but that fatherhood may provide a buffer against transient mild stressors (i.e., weighing and blood sampling in the control groups) in this monogamous and biparental rodent. PMID:23582312
Talukder, Shamim; Farhana, Dina; Vitta, Bineti; Greiner, Ted
2017-01-01
In rural Bangladesh, most births take place at home. There is little evidence regarding the influence of traditional birth attendants (TBAs) or community volunteers (CVs) on early infant feeding practices. We conducted a pragmatic cluster randomized controlled trial in Panchagarh District to examine the effects of training and post-training supervision of TBAs/CVs on early breastfeeding practices. Nine unions were randomized into three groups of three unions. We compared outcomes between mothers in a control group (CG), those living in unions where TBAs/CVs had received a 5-day training in early feeding practices (TG) and those living in unions where TBAs/CVs were both trained and supervised (SG). A total of 1182 mothers of infants aged 0-6 months were interviewed at baseline. After 6 months of intervention, an endline survey was conducted on a different sample of 1148 mothers of infants aged 0-6 months in the same areas. In both intervention areas, TBAs/CVs made regular home visits and attended births whenever possible. Rates of early initiation of breastfeeding, avoidance of prelacteal feeds and exclusive breastfeeding were compared between groups using cluster-controlled mixed model logistic regression. At endline, both intervention groups had significantly higher proportions of mothers who reported early initiation of breastfeeding (CG: 88%, TG: 96%, SG: 96%) and avoidance of prelacteal feeds (CG: 48%, TG: 80%, SG: 88%) compared with the control group; there were no significant differences between the two intervention groups. The endline rates of reported exclusive breastfeeding were not significantly different among groups (CG: 67%, TG: 76%, SG: 83%). © 2016 John Wiley & Sons Ltd.
Simas, Bruna B; Nunes, Everson A; Crestani, Carlos C; Speretta, Guilherme F
2018-05-01
Obesity and chronic stress are considered independent risk factors for the development of cardiovascular diseases and changes in autonomic system activity. However, the cardiovascular consequences induced by the association between high-fat diet (HFD) and chronic stress are not fully understood. We hypothesized that the association between HFD and exposure to a chronic variable stress (CVS) protocol for four weeks might exacerbate the cardiovascular and metabolic disturbances in rats when compared to these factors singly. To test this hypothesis, male Wistar rats were divided into four groups: control-standard chow diet (SD; n = 8); control-HFD (n = 8); CVS-SD (n = 8); and CVS-HFD (n = 8). The CVS consisted of repeated exposure of the rats to different inescapable and unpredictable stressors (restraint tress; damp sawdust, cold, swim stress and light cycle inversion). We evaluated cardiovascular function, autonomic activity, dietary intake, adiposity and metabolism. The HFD increased body weight, adiposity and blood glucose concentration (∼15%) in both control and CVS rats. The CVS-HFD rats showed decreased insulin sensitivity (25%) compared to CVS-SD rats. The control-HFD and CVS-HFD rats presented increased intrinsic heart rate (HR) values (∼8%). CVS increased cardiac sympathetic activity (∼65%) in both SD- and HFD-fed rats. The HFD increased basal HR (∼10%). Blood pressure and baroreflex analyzes showed no differences among the experimental groups. In conclusion, the present data indicate absence of interaction on autonomic imbalance evoked by either CVS or HFD. Additionally, HFD increased HR and evoked metabolic disruptions which are independent of stress exposure.
Computer vision syndrome: A review.
Gowrisankaran, Sowjanya; Sheedy, James E
2015-01-01
Computer vision syndrome (CVS) is a collection of symptoms related to prolonged work at a computer display. This article reviews the current knowledge about the symptoms, related factors and treatment modalities for CVS. Relevant literature on CVS published during the past 65 years was analyzed. Symptoms reported by computer users are classified into internal ocular symptoms (strain and ache), external ocular symptoms (dryness, irritation, burning), visual symptoms (blur, double vision) and musculoskeletal symptoms (neck and shoulder pain). The major factors associated with CVS are either environmental (improper lighting, display position and viewing distance) and/or dependent on the user's visual abilities (uncorrected refractive error, oculomotor disorders and tear film abnormalities). Although the factors associated with CVS have been identified the physiological mechanisms that underlie CVS are not completely understood. Additionally, advances in technology have led to the increased use of hand-held devices, which might impose somewhat different visual challenges compared to desktop displays. Further research is required to better understand the physiological mechanisms underlying CVS and symptoms associated with the use of hand-held and stereoscopic displays.
Purchase decision-making is modulated by vestibular stimulation.
Preuss, Nora; Mast, Fred W; Hasler, Gregor
2014-01-01
Purchases are driven by consumers' product preferences and price considerations. Using caloric vestibular stimulation (CVS), we investigated the role of vestibular-affective circuits in purchase decision-making. CVS is an effective noninvasive brain stimulation method, which activates vestibular and overlapping emotional circuits (e.g., the insular cortex and the anterior cingulate cortex (ACC)). Subjects were exposed to CVS and sham stimulation while they performed two purchase decision-making tasks. In Experiment 1 subjects had to decide whether to purchase or not. CVS significantly reduced probability of buying a product. In Experiment 2 subjects had to rate desirability of the products and willingness to pay (WTP) while they were exposed to CVS and sham stimulation. CVS modulated desirability of the products but not WTP. The results suggest that CVS interfered with emotional circuits and thus attenuated the pleasant and rewarding effect of acquisition, which in turn reduced purchase probability. The present findings contribute to the rapidly growing literature on the neural basis of purchase decision-making.
Purchase decision-making is modulated by vestibular stimulation
Preuss, Nora; Mast, Fred W.; Hasler, Gregor
2014-01-01
Purchases are driven by consumers’ product preferences and price considerations. Using caloric vestibular stimulation (CVS), we investigated the role of vestibular-affective circuits in purchase decision-making. CVS is an effective noninvasive brain stimulation method, which activates vestibular and overlapping emotional circuits (e.g., the insular cortex and the anterior cingulate cortex (ACC)). Subjects were exposed to CVS and sham stimulation while they performed two purchase decision-making tasks. In Experiment 1 subjects had to decide whether to purchase or not. CVS significantly reduced probability of buying a product. In Experiment 2 subjects had to rate desirability of the products and willingness to pay (WTP) while they were exposed to CVS and sham stimulation. CVS modulated desirability of the products but not WTP. The results suggest that CVS interfered with emotional circuits and thus attenuated the pleasant and rewarding effect of acquisition, which in turn reduced purchase probability. The present findings contribute to the rapidly growing literature on the neural basis of purchase decision-making. PMID:24600365
40 CFR 91.425 - CVS calibration frequency.
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.425 CVS calibration frequency. Calibrate the CVS positive displacement pump or critical flow venturi...
40 CFR 91.425 - CVS calibration frequency.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.425 CVS calibration frequency. Calibrate the CVS positive displacement pump or critical flow venturi...
40 CFR 91.425 - CVS calibration frequency.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.425 CVS calibration frequency. Calibrate the CVS positive displacement pump or critical flow venturi...
40 CFR 91.425 - CVS calibration frequency.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.425 CVS calibration frequency. Calibrate the CVS positive displacement pump or critical flow venturi...
40 CFR 91.425 - CVS calibration frequency.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Gaseous Exhaust Test Procedures § 91.425 CVS calibration frequency. Calibrate the CVS positive displacement pump or critical flow venturi...
Examing nursing students' understanding of the cardiovascular system in a BSN program
NASA Astrophysics Data System (ADS)
Stuart, Parker Emerson
This study investigated the alignment of important cardiovascular system (CVS) concepts identified by expert nurses with nursing student's knowledge. Specifically, it focused on the prevalence of nursing students' alternative conceptions for these important concepts as a potential reason for a theory-practice gap in nursing (Corlett, 2000; Jordan, 1994). This is the first study to target nursing student alternative conceptions exclusively whereas other studies focused on diverse groups of undergraduates' CVS knowledge (Michael et al., 2002). The study was divided into two phases and used a case study approach with each phase of the study representing a single case. The first phase of the study sought to understand what CVS concepts expert nurses deemed relevant to their daily practice and how these experts used these concepts. The second phase identified nursing student alternative conceptions through the use of open-ended scenarios based on the results of phase I. For the first phase of the study involved four CVS expert nurses practicing in emergency rooms and cardiac intensive care units at two local hospitals. Interviews were used to elicit important CVS concepts. The expert nurses identified five broad concepts as important to their practice. These concepts were a) cardiovascular anatomical concepts; b) cardiovascular physiological concepts; c) homeostasis and diseases of the CVS; d) the interdependence and interaction of the CVS with other organ systems and e) the intersection of the CVS and technology in patient diagnosis and treatment. These finding reinforce concepts already being taught to nursing students but also suggest that instruction should focus more on how the CVS interacts with other organ systems and how technology and the CVS interact. The presence of alternative conceptions in the nursing students was examined through the use of open-ended questions. A total of 17 students fully completed the scenario questions. Results indicate that this group of nursing students hold some CVS alternative conceptions. Overall, the alternative conceptions can be grouped into four categories: a) CVS anatomy, b) blood flow and pressure, c) anthropomorphic views and d) miscellaneous alternative conceptions. These findings suggest there is indeed a misalignment between expert nurses' and nursing students' knowledge of the CVS with this misalignment potentially contributing to the theory-practice gap.
40 CFR 90.425 - CVS calibration frequency.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust Test Procedures § 90.425 CVS calibration frequency. Calibrate the CVS positive displacement pump or...
40 CFR 90.425 - CVS calibration frequency.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust Test Procedures § 90.425 CVS calibration frequency. Calibrate the CVS positive displacement pump or...
40 CFR 90.425 - CVS calibration frequency.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust Test Procedures § 90.425 CVS calibration frequency. Calibrate the CVS positive displacement pump or...
40 CFR 90.425 - CVS calibration frequency.
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust Test Procedures § 90.425 CVS calibration frequency. Calibrate the CVS positive displacement pump or...
40 CFR 90.425 - CVS calibration frequency.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust Test Procedures § 90.425 CVS calibration frequency. Calibrate the CVS positive displacement pump or...
Kumar, Nilay; Bashar, Qumseya; Reddy, Naveen; Sengupta, Jyotirmoy; Ananthakrishnan, Ashwin; Schroeder, Abigail; Hogan, Walter J; Venkatesan, Thangam
2012-05-28
Cyclic Vomiting Syndrome (CVS) is a well-recognized functional gastrointestinal disorder in children but its presentation is poorly understood in adults. Genetic differences in pediatric-onset (presentation before age 18) and adult-onset CVS have been reported recently but their clinical features and possible differences in response to therapy have not been well studied. This was a retrospective review of 101 CVS patients seen at the Medical College of Wisconsin between 2006 and 2008. Rome III criteria were utilized to make the diagnosis of CVS. Our study population comprised of 29(29%) pediatric-onset and 72 (71%) adult-onset CVS patients. Pediatric-onset CVS patients were more likely to be female (86% vs. 57%, p = 0.005) and had a higher prevalence of CVS plus (CVS + neurocognitive disorders) as compared to adult-onset CVS patients (14% vs. 3%, p = 0.05). There was a longer delay in diagnosis (10 ± 7 years) in the pediatric-onset group when compared to (5 ± 7 years) adult-onset CVS group (p = 0.001). Chronic opiate use was less frequent in the pediatric-onset group compared to adult-onset patients (0% vs. 23%, p = 0.004). Aside from these differences, the two groups were similar with regards to their clinical features and the time of onset of symptoms did not predict response to standard treatment. The majority of patients (86%) responded to treatment with tricyclic antidepressants, anticonvulsants (topiramate), coenzyme Q-10, and L-carnitine. Non-response to therapy was associated with coalescence of symptoms, chronic opiate use and more severe disease as characterized by longer episodes, greater number of emergency department visits in the year prior to presentation, presence of disability and non-compliance on univariate analysis. On multivariate analysis, only compliance to therapy was associated with a response. (88% vs. 38%, Odds Ratio, OR 9.6; 95% Confidence Interval [CI], 1.18-77.05). Despite reported genetic differences, the clinical features and response to standard therapy in pediatric- and adult-onset CVS were mostly similar. Most patients (86%) responded to therapy and compliance was the only factor associated with a response.
Moral, Juan; Xaviér, Carlos J; Viruega, José R; Roca, Luis F; Caballero, Juan; Trapero, Antonio
2017-01-01
Anthracnose of olive ( Olea europaea ssp. europaea L.), caused by Colletotrichum species, is a serious disease causing fruit rot and branch dieback, whose epidemics are highly dependent on cultivar susceptibility and environmental conditions. Over a period of 10 years, there have been three severe epidemics in Andalusia (southern Spain) that allowed us to complete the assessment of the World Olive Germplasm Bank of Córdoba, one of the most important cultivar collections worldwide.A total of 308 cultivars from 21 countries were evaluated, mainly Spain (174 cvs.), Syria (29 cvs.), Italy (20 cvs.), Turkey (15 cvs.), and Greece (16 cvs.). Disease assessments were performed using a 0-10 rating scale, specifically developed to estimate the incidence of symptomatic fruit in the tree canopy. Also, the susceptibility of five reference cultivars was confirmed by artificial inoculation. Because of the direct relationship between the maturity of the fruit and their susceptibility to the pathogen, evaluations were performed at the end of fruit ripening, which forced coupling assessments according to the maturity state of the trees. By applying the cluster analysis to the 308 cultivars, these were classified as follows: 66 cvs. highly susceptible (21.4%), 83 cvs. susceptible (26.9%), 66 cvs. moderately susceptible (21.4%), 61 cvs. resistant (19.8%), and 32 cvs. highly resistant (10.4%). Representative cultivars of these five categories are "Ocal," "Lechín de Sevilla," "Arbequina," "Picual," and "Frantoio," respectively. With some exceptions, such as cvs. Arbosana, Empeltre and Picual, most of the Spanish cultivars, such as "Arbequina," "Cornicabra," "Hojiblanca," "Manzanilla de Sevilla," "Morisca," "Picudo," "Farga," and "Verdial de Huévar" are included in the categories of moderately susceptible, susceptible or highly susceptible. The phenotypic evaluation of anthracnose reaction is a limiting factor for the selection of olive cultivars by farmers, technicians, and breeders.
Moral, Juan; Xaviér, Carlos J.; Viruega, José R.; Roca, Luis F.; Caballero, Juan; Trapero, Antonio
2017-01-01
Anthracnose of olive (Olea europaea ssp. europaea L.), caused by Colletotrichum species, is a serious disease causing fruit rot and branch dieback, whose epidemics are highly dependent on cultivar susceptibility and environmental conditions. Over a period of 10 years, there have been three severe epidemics in Andalusia (southern Spain) that allowed us to complete the assessment of the World Olive Germplasm Bank of Córdoba, one of the most important cultivar collections worldwide.A total of 308 cultivars from 21 countries were evaluated, mainly Spain (174 cvs.), Syria (29 cvs.), Italy (20 cvs.), Turkey (15 cvs.), and Greece (16 cvs.). Disease assessments were performed using a 0–10 rating scale, specifically developed to estimate the incidence of symptomatic fruit in the tree canopy. Also, the susceptibility of five reference cultivars was confirmed by artificial inoculation. Because of the direct relationship between the maturity of the fruit and their susceptibility to the pathogen, evaluations were performed at the end of fruit ripening, which forced coupling assessments according to the maturity state of the trees. By applying the cluster analysis to the 308 cultivars, these were classified as follows: 66 cvs. highly susceptible (21.4%), 83 cvs. susceptible (26.9%), 66 cvs. moderately susceptible (21.4%), 61 cvs. resistant (19.8%), and 32 cvs. highly resistant (10.4%). Representative cultivars of these five categories are “Ocal,” “Lechín de Sevilla,” “Arbequina,” “Picual,” and “Frantoio,” respectively. With some exceptions, such as cvs. Arbosana, Empeltre and Picual, most of the Spanish cultivars, such as “Arbequina,” “Cornicabra,” “Hojiblanca,” “Manzanilla de Sevilla,” “Morisca,” “Picudo,” “Farga,” and “Verdial de Huévar” are included in the categories of moderately susceptible, susceptible or highly susceptible. The phenotypic evaluation of anthracnose reaction is a limiting factor for the selection of olive cultivars by farmers, technicians, and breeders. PMID:29163612
OnabotulinumtoxinA Injections for the Treatment of Cyclic Vomiting Syndrome.
Hayes, William J; Weisensee, Laurie A; Kappes, John A; Dalton, Shawn M; Lemon, Michael D
2015-05-01
Cyclic vomiting syndrome (CVS) is a disorder characterized by episodes of nausea and vomiting lasting 1 to 5 days, followed by asymptomatic periods. The etiology and pathophysiology of CVS are unknown, but CVS shares similar characteristics to those of migraine headaches. Tricyclic antidepressants have the most evidence and are generally effective for prophylaxis of further episodes in patients with CVS. Second-line pharmacotherapies typically target specific comorbid symptoms or conditions and may include antiepileptic or antimigraine drugs, benzodiazepines, antispasmodics, proton pump inhibitors, antiemetics, and analgesics. OnabotulinumtoxinA (ONABoNT-A) injections have not been studied in the population with CVS but are regarded as a pharmacotherapeutic option for migraine headaches. We describe a 45-year-old woman with a 5-year history of CVS who had failed previous typical prophylactic migraine and CVS pharmacotherapies and was referred to the neurology clinic for management of both of these conditions. On review, the neurologist noted a correlation of the patient's headaches with her CVS symptoms. ONABoNT-A injections were started at 155 units intramuscularly every 12 weeks for her migraine headaches, which also dramatically improved her CVS. The main adverse effect reported by the patient was numbness and weakness in her left shoulder after the injections, which are symptoms consistent with ONABoNT-A injection use; however, these symptoms typically resolved a few days later. Regarded as a pharmacotherapeutic option for migraine headache prophylaxis, ONABoNT-A injections have demonstrated modest efficacy in preventing migraine headaches. Clinicians should be aware that ONABoNT-A injections may also have a role in the prophylaxis of CVS. © 2015 Pharmacotherapy Publications, Inc.
PLUMED 2: New feathers for an old bird
NASA Astrophysics Data System (ADS)
Tribello, Gareth A.; Bonomi, Massimiliano; Branduardi, Davide; Camilloni, Carlo; Bussi, Giovanni
2014-02-01
Enhancing sampling and analyzing simulations are central issues in molecular simulation. Recently, we introduced PLUMED, an open-source plug-in that provides some of the most popular molecular dynamics (MD) codes with implementations of a variety of different enhanced sampling algorithms and collective variables (CVs). The rapid changes in this field, in particular new directions in enhanced sampling and dimensionality reduction together with new hardware, require a code that is more flexible and more efficient. We therefore present PLUMED 2 here—a complete rewrite of the code in an object-oriented programming language (C++). This new version introduces greater flexibility and greater modularity, which both extends its core capabilities and makes it far easier to add new methods and CVs. It also has a simpler interface with the MD engines and provides a single software library containing both tools and core facilities. Ultimately, the new code better serves the ever-growing community of users and contributors in coping with the new challenges arising in the field.
NASA Astrophysics Data System (ADS)
Hashemian, Behrooz; Millán, Daniel; Arroyo, Marino
2013-12-01
Collective variables (CVs) are low-dimensional representations of the state of a complex system, which help us rationalize molecular conformations and sample free energy landscapes with molecular dynamics simulations. Given their importance, there is need for systematic methods that effectively identify CVs for complex systems. In recent years, nonlinear manifold learning has shown its ability to automatically characterize molecular collective behavior. Unfortunately, these methods fail to provide a differentiable function mapping high-dimensional configurations to their low-dimensional representation, as required in enhanced sampling methods. We introduce a methodology that, starting from an ensemble representative of molecular flexibility, builds smooth and nonlinear data-driven collective variables (SandCV) from the output of nonlinear manifold learning algorithms. We demonstrate the method with a standard benchmark molecule, alanine dipeptide, and show how it can be non-intrusively combined with off-the-shelf enhanced sampling methods, here the adaptive biasing force method. We illustrate how enhanced sampling simulations with SandCV can explore regions that were poorly sampled in the original molecular ensemble. We further explore the transferability of SandCV from a simpler system, alanine dipeptide in vacuum, to a more complex system, alanine dipeptide in explicit water.
Hashemian, Behrooz; Millán, Daniel; Arroyo, Marino
2013-12-07
Collective variables (CVs) are low-dimensional representations of the state of a complex system, which help us rationalize molecular conformations and sample free energy landscapes with molecular dynamics simulations. Given their importance, there is need for systematic methods that effectively identify CVs for complex systems. In recent years, nonlinear manifold learning has shown its ability to automatically characterize molecular collective behavior. Unfortunately, these methods fail to provide a differentiable function mapping high-dimensional configurations to their low-dimensional representation, as required in enhanced sampling methods. We introduce a methodology that, starting from an ensemble representative of molecular flexibility, builds smooth and nonlinear data-driven collective variables (SandCV) from the output of nonlinear manifold learning algorithms. We demonstrate the method with a standard benchmark molecule, alanine dipeptide, and show how it can be non-intrusively combined with off-the-shelf enhanced sampling methods, here the adaptive biasing force method. We illustrate how enhanced sampling simulations with SandCV can explore regions that were poorly sampled in the original molecular ensemble. We further explore the transferability of SandCV from a simpler system, alanine dipeptide in vacuum, to a more complex system, alanine dipeptide in explicit water.
Adult cyclical vomiting syndrome: a disorder of allostatic regulation?
Levinthal, D J; Bielefeldt, K
2014-08-01
Cyclic vomiting syndrome (CVS) is an idiopathic illness characterized by stereotypic and sudden-onset episodes of intense retching and repetitive vomiting that are often accompanied by severe abdominal pain. Many associated factors that predict CVS attacks, such as prolonged periods of fasting, sleep deprivation, physical and emotional stress, or acute anxiety, implicate sympathetic nervous system activation as a mechanism that may contribute to CVS pathogenesis. Furthermore, adult patients with CVS tend to have a history of early adverse life events, mood disorders, chronic stress, and drug abuse-all associations that may potentiate sympathetic neural activity. In this review, we set forth a conceptual model in which CVS is viewed as a brain disorder involving maladaptive plasticity within central neural circuits important for allostatic regulation of the sympathetic nervous system. This model not only can account for the varied clinical observations that are linked with CVS, but also has implications for potential therapeutic interventions. Thus, it is likely that cognitive behavioral therapy, stress management ("mind-body") interventions, regular exercise, improved sleep, and avoidance of cannabis and opiate use could have positive influences on the clinical course for patients with CVS.
Hidden benefits of electric vehicles for addressing climate change.
Li, Canbing; Cao, Yijia; Zhang, Mi; Wang, Jianhui; Liu, Jianguo; Shi, Haiqing; Geng, Yinghui
2015-03-19
There is an increasingly hot debate on whether the replacement of conventional vehicles (CVs) by electric vehicles (EVs) should be delayed or accelerated since EVs require higher cost and cause more pollution than CVs in the manufacturing process. Here we reveal two hidden benefits of EVs for addressing climate change to support the imperative acceleration of replacing CVs with EVs. As EVs emit much less heat than CVs within the same mileage, the replacement can mitigate urban heat island effect (UHIE) to reduce the energy consumption of air conditioners, benefitting local and global climates. To demonstrate these effects brought by the replacement of CVs by EVs, we take Beijing, China, as an example. EVs emit only 19.8% of the total heat emitted by CVs per mile. The replacement of CVs by EVs in 2012 could have mitigated the summer heat island intensity (HII) by about 0.94°C, reduced the amount of electricity consumed daily by air conditioners in buildings by 14.44 million kilowatt-hours (kWh), and reduced daily CO2 emissions by 10,686 tonnes.
Hidden benefits of electric vehicles for addressing climate change
Li, Canbing; Cao, Yijia; Zhang, Mi; ...
2015-03-19
There is an increasingly hot debate on whether the replacement of conventional vehicles (CVs) by electric vehicles (EVs) should be delayed or accelerated since EVs require higher cost and cause more pollution than CVs in the manufacturing process. Here we reveal two hidden benefits of EVs for addressing climate change to support the imperative acceleration of replacing CVs with EVs. As EVs emit much less heat than CVs within the same mileage, the replacement can mitigate urban heat island effect (UHIE) to reduce the energy consumption of air conditioners, benefitting local and global climates. To demonstrate these effects brought bymore » the replacement of CVs by EVs, we take Beijing, China, as an example. EVs emit only 19.8% of the total heat emitted by CVs per mile. The replacement of CVs by EVs in 2012 could have mitigated the summer heat island intensity (HII) by about 0.94°C, reduced the amount of electricity consumed daily by air conditioners in buildings by 14.44 million kilowatt-hours (kWh), and reduced daily CO₂ emissions by 10,686 tonnes.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Canbing; Cao, Yijia; Zhang, Mi
There is an increasingly hot debate on whether the replacement of conventional vehicles (CVs) by electric vehicles (EVs) should be delayed or accelerated since EVs require higher cost and cause more pollution than CVs in the manufacturing process. Here we reveal two hidden benefits of EVs for addressing climate change to support the imperative acceleration of replacing CVs with EVs. As EVs emit much less heat than CVs within the same mileage, the replacement can mitigate urban heat island effect (UHIE) to reduce the energy consumption of air conditioners, benefitting local and global climates. To demonstrate these effects brought bymore » the replacement of CVs by EVs, we take Beijing, China, as an example. EVs emit only 19.8% of the total heat emitted by CVs per mile. The replacement of CVs by EVs in 2012 could have mitigated the summer heat island intensity (HII) by about 0.94°C, reduced the amount of electricity consumed daily by air conditioners in buildings by 14.44 million kilowatt-hours (kWh), and reduced daily CO₂ emissions by 10,686 tonnes.« less
40 CFR 86.1540 - Idle exhaust sample analysis.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission... the CVS sampling system is used, the analysis procedures for dilute CO and CO2 specified in 40 CFR part 1065 apply. Follow the raw CO2 analysis procedure specified in 40 CFR part 1065, subpart F, for...
40 CFR 86.1540 - Idle exhaust sample analysis.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for... CVS sampling system is used, the analysis procedures for dilute CO and CO2 specified in 40 CFR part 1065 apply. Follow the raw CO2 analysis procedure specified in 40 CFR part 1065, subpart F, for the raw...
40 CFR 86.1540 - Idle exhaust sample analysis.
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission... the CVS sampling system is used, the analysis procedures for dilute CO and CO2 specified in 40 CFR part 1065 apply. Follow the raw CO2 analysis procedure specified in 40 CFR part 1065, subpart F, for...
CSF biomarker variability in the Alzheimer’s Association quality control program
Mattsson, Niklas; Andreasson, Ulf; Persson, Staffan; Carrillo, Maria C.; Collins, Steven; Chalbot, Sonia; Cutler, Neal; Dufour-Rainfray, Diane; Fagan, Anne M.; Heegaard, Niels H. H.; Hsiung, Ging-Yuek Robin; Hyman, Bradley; Iqbal, Khalid; Lachno, D. Richard; Lleó, Alberto; Lewczuk, Piotr; Molinuevo, José L.; Parchi, Piero; Regeniter, Axel; Rissman, Robert; Rosenmann, Hanna; Sancesario, Giuseppe; Schröder, Johannes; Shaw, Leslie M.; Teunissen, Charlotte E.; Trojanowski, John Q.; Vanderstichele, Hugo; Vandijck, Manu; Verbeek, Marcel M.; Zetterberg, Henrik; Blennow, Kaj; Käser, Stephan A.
2013-01-01
Background The cerebrospinal fluid (CSF) biomarkers amyloid beta 1–42, total tau, and phosphorylated tau are used increasingly for Alzheimer’s disease (AD) research and patient management. However, there are large variations in biomarker measurements among and within laboratories. Methods Data from the first nine rounds of the Alzheimer’s Association quality control program was used to define the extent and sources of analytical variability. In each round, three CSF samples prepared at the Clinical Neurochemistry Laboratory (Mölndal, Sweden) were analyzed by single-analyte enzyme-linked immunosorbent assay (ELISA), a multiplexing xMAP assay, or an immunoassay with electrochemoluminescence detection. Results A total of 84 laboratories participated. Coefficients of variation (CVs) between laboratories were around 20% to 30%; within-run CVs, less than 5% to 10%; and longitudinal within-laboratory CVs, 5% to 19%. Interestingly, longitudinal within-laboratory CV differed between biomarkers at individual laboratories, suggesting that a component of it was assay dependent. Variability between kit lots and between laboratories both had a major influence on amyloid beta 1–42 measurements, but for total tau and phosphorylated tau, between-kit lot effects were much less than between-laboratory effects. Despite the measurement variability, the between-laboratory consistency in classification of samples (using prehoc-derived cutoffs for AD) was high (>90% in 15 of 18 samples for ELISA and in 12 of 18 samples for xMAP). Conclusions The overall variability remains too high to allow assignment of universal biomarker cutoff values for a specific intended use. Each laboratory must ensure longitudinal stability in its measurements and use internally qualified cutoff levels. Further standardization of laboratory procedures and improvement of kit performance will likely increase the usefulness of CSF AD biomarkers for researchers and clinicians. PMID:23622690
Good performance of an immunoassay based method for nevirapine measurements in human breast milk.
Salado-Rasmussen, Kirsten; Theilgaard, Zahra Persson; Chiduo, Mercy; Pedersen, Court; Gerstoft, Jan; Katzenstein, Terese Lea
2011-07-01
Understanding the distribution of antiretro-virals in breastfeeding HIV-positive mothers is essential, both for prevention of mother-to-child HIV transmission and for research on the development of drug resistance. The ARK nevirapine (NVP)-test is an immunoassay method for nevirapine measurements, developed and validated for plasma use. In this study, the ARK NVP-test was evaluated for measurement of nevirapine concentrations in breast milk. High performance liquid chromatography (HPLC) is the method currently used to determine nevirapine in breast milk. This method, however, requires complicated extraction techniques. The ARK method employs an immunoassay technology and requires a small sample volume (40 μL) and no pre-treatment of the samples. Commercial enzyme and antibody were used and calibration standards and quality controls were prepared from pooled breast milk from HIV-uninfected women. Clinical samples from HIV-infected women receiving a single-dose of nevirapine were analyzed. Precision and accuracy were evaluated with two concentrations of quality control materials analyzed in three replicates on four different days and was <4%, and between 96.5% and 104.6%, respectively. Clinical samples were analyzed and CVs ranged from 0.0% to 11.1%. The median nevirapine concentration in breast milk 1 week post-partum was 0.29 μg/mL (range 0.11-0.90 μg/mL) in women treated with a single-dose of nevirapine. The ease of use and small sample volume makes the ARK assay an attractive alternative to HPLC analyses for determinations of nevirapine concentrations in breast milk.
Sweet food improves chronic stress-induced irritable bowel syndrome-like symptoms in rats.
Rho, Sang-Gyun; Kim, Yong Sung; Choi, Suck Chei; Lee, Moon Young
2014-03-07
To investigate whether palatable sweet foods have a beneficial effect on chronic stress-induced colonic motility and inflammatory cytokines. Adult male rats were divided into 3 groups: control (CON, n = 5), chronic variable stress with chow (CVS-A, n = 6), and chronic variable stress with chow and sweet food (CVS-B, n = 6). The rats were fed standard rodent chow as the chow food and/or AIN-76A as the sweet food. A food preference test for AIN-76A was performed in another group of normal rats (n = 10) for twelve days. Fecal pellet output (FPO) was measured for 6 wk during water bedding stress in the CVS groups. The weight of the adrenal glands, adrenocorticotropic hormone (ACTH) and corticosterone levels in plasma were measured. The expression levels of transforming growth factor-β, interleukin (IL)-2, and interferon-gamma (IFN-γ) were measured in the distal part of colonic tissues and plasma using Western blot analysis. In sweet preference test, all rats initially preferred sweet food to chow food. However, the consumption rate of sweet food gradually decreased and reduced to below 50% of total intake eight days after sweet food feeding. Accumulated FPO was higher in the CVS-A group compared with the CVS-B group over time. All stress groups showed significant increases in the adrenal to body weight ratio (CVS-A, 0.14 ± 0.01; CVS-B, 0.14 ± 0.01) compared with the control group (0.12 ± 0.01, P < 0.05). The plasma corticosterone and ACTH levels were significantly higher in the CVS-A (537.42 ± 32.95, 44.44 ± 6.54 pg/mL) and CVS-B (655.07 ± 30.82, 65.46 ± 4.44 pg/mL) groups than in the control group (46.96 ± 13.29, 8.51 ± 1.35 pg/mL, P < 0.05). Notably, the ratio of corticosterone to ACTH was significantly increased in the CVS-A group only. Rats exposed to CVS displayed significantly increased expression of IL-2 and IFN-γ in the plasma and distal colon compared to the control group, whereas this effect was significantly attenuated in the CVS-B group. These results suggest that concurrent sweet food ingestion during CVS might have an effect on the reduction of stress-induced colonic hyper-motility and pro-inflammatory cytokine production in rats.
Cyclic vomiting syndrome: diagnostic approach and current management strategies.
Hayes, William J; VanGilder, Deidra; Berendse, Joseph; Lemon, Michael D; Kappes, John A
2018-01-01
Cyclic vomiting syndrome (CVS) is a disorder characterized by episodes of nausea and vomiting lasting for 1-5 days followed by asymptomatic periods. The etiology of CVS is unknown, but it shares similar characteristics to migraine headaches. CVS is generally classified as having four phases: prodromal, acute/vomiting/hyperemesis, recovery, and remission/interepisodic. Current management strategies include trigger avoidance, abortive and prophylactic medication therapies, and supportive care. The goal of therapy for the remission phase is prophylaxis of further episodes. Antidepressant, antiepileptic, and antimigraine medications show an overall reduction or remission of CVS symptoms in more than 70% of patients. This article provides a summary of diagnostic strategies and reviews current management strategies for CVS.
Cyclic vomiting syndrome: diagnostic approach and current management strategies
Hayes, William J; VanGilder, Deidra; Berendse, Joseph; Lemon, Michael D; Kappes, John A
2018-01-01
Cyclic vomiting syndrome (CVS) is a disorder characterized by episodes of nausea and vomiting lasting for 1–5 days followed by asymptomatic periods. The etiology of CVS is unknown, but it shares similar characteristics to migraine headaches. CVS is generally classified as having four phases: prodromal, acute/vomiting/hyperemesis, recovery, and remission/interepisodic. Current management strategies include trigger avoidance, abortive and prophylactic medication therapies, and supportive care. The goal of therapy for the remission phase is prophylaxis of further episodes. Antidepressant, antiepileptic, and antimigraine medications show an overall reduction or remission of CVS symptoms in more than 70% of patients. This article provides a summary of diagnostic strategies and reviews current management strategies for CVS. PMID:29520160
Control of fluid flow during Bridgman crystal growth using low-frequency vibrational stirring
NASA Astrophysics Data System (ADS)
Zawilski, Kevin Thomas
The goal of this research program was to develop an in depth understanding of a promising new method for stirring crystal growth melts called coupled vibrational stirring (CVS). CVS is a mixing technique that can be used in sealed systems and produces rapid mixing through vortex flows. Under normal operating conditions, CVS uses low-frequency vibrations to move the growth crucible along a circular path, producing a surface wave and convection in the melt. This research focused on the application of CVS to the vertical Bridgman technique. CVS generated flows were directly studied using a physical modeling system containing water/glycerin solutions. Sodium nitrate was chosen as a model growth system because the growth process could be directly observed using a transparent furnace. Lead magnesium niobate-lead titanate (PMNT) was chosen as the third system because of its potential application for high performance solid state transducers and actuators. In this study, the critical parameters for controlling CVS flows in cylindrical Bridgman systems were established. One of the most important results obtained was the dependence of an axial velocity gradient on the vibrational frequency. By changing the frequency, the intensity of fluid flow at a given depth can be easily manipulated. The intensity of CVS flows near the crystal-melt interface was found to be important. When flow intensity near the interface increased during growth, large growth rate fluctuations and significant changes in interface shape were observed. To eliminate such fluctuations, a constant flow rate near the crystal-melt interface was maintained by decreasing the vibrational frequency. A continuous frequency ramp was found to be essential to grow crystals of good quality under strong CVS flows. CVS generated flows were also useful in controlling the shape of the growth interface. In the sodium nitrate system without stirring, high growth rates produced a very concave interface. By adjusting the flow intensity near the interface, CVS flows were able to flatten the growth interface under these extreme growth conditions.
Kotoda, Atsushi; Akimoto, Tetsu; Sugase, Taro; Yamamoto, Hisashi; Kusano, Eiji
2013-01-01
Central venous stenosis (CVS) is a serious complication for chronic hemodialysis (HD) patients. Previous reports of CVS have focused on prior central venous catheterization, because of the higher prevalence and potential for prevention of such an event. However, recent studies have demonstrated that CVS may also develop without a history of central venous catheterization. Although information about the etiological backgrounds regarding the development of CVS without previous central venous catheterization have gradually accumulated, the clinical impact of the chronic compression of the central venous system by the surrounding structures, which may likely determine the central venous susceptibility to CVS, remains poorly understood. This study proposes the hypothesis that the combination of chronic venous compression at the level of thoracic outlet characterized by the natural physique and elevated venous flow induced by the creation of vascular access should be evaluated as a potential factor for the development of CVS, since they may accelerate the development of venous stenosis, presumably through the stimulation of intimal hyperplasia, and thereby the subclavian venous susceptibility to CVS should be determined. Copyright © 2012 Elsevier Ltd. All rights reserved.
Moudi, Zahra; Miri-Moghaddam, Ebrahim
2017-06-01
In the present study, an embedded design was applied in order to conduct a one-year cross-sectional audit of chorionic villus sampling (CVS) and foetal outcomes affected by β-thalassemia major (β-TM) in a prenatal diagnosis (PND) setting. In addition, we explored the decisions regarding pregnancy termination among women whose pregnancy (or child) was affected by β-TM. In the quantitative phase, the available data in the clients' medical records were analysed, while the qualitative phase was performed using a grounded theory method. Interviews were performed with nine pregnant women who had decided against pregnancy termination despite positive CVS results, 11 mothers who had admitted their child to the thalassemia ward for blood transfusion, and 19 mothers who had received positive CVS results and had decided against pregnancy termination in the preceding year. Over one year, 18.6 % of women decided against pregnancy termination despite positive CVS results. Two main themes related to decisions against pregnancy termination emerged from the qualitative data: 1) Cognitive factors (questioning the reliability of the tests or doubts about the accuracy of the results, understanding disease recurrence, curability, perceived severity of the disease, and lack of "real-life experiences"); and 2) Sociocultural responsiveness (family opposition, responsibility before God, and self-responsiveness). All of the mentioned factors could intensify fear of abortion in couples due to possible regret, and encourage a decision against pregnancy termination.
40 CFR 86.110-90 - Exhaust gas sampling system; diesel vehicles.
Code of Federal Regulations, 2013 CFR
2013-07-01
... follows: (1) This sampling system requires the use of a PDP-CVS or a CFV sample system with heat exchanger... 235° ±15 °F (113° ±8 °C) prior to the test and during breaks in testing (insulation may remain in...) or less. (ii) A heat exchanger is required. (iii) The gas mixture temperature, measured at a point...
40 CFR 86.110-90 - Exhaust gas sampling system; diesel vehicles.
Code of Federal Regulations, 2012 CFR
2012-07-01
... follows: (1) This sampling system requires the use of a PDP-CVS or a CFV sample system with heat exchanger... 235° ±15 °F (113° ±8 °C) prior to the test and during breaks in testing (insulation may remain in...) or less. (ii) A heat exchanger is required. (iii) The gas mixture temperature, measured at a point...
Osman, Osama O; El-Magzoub, Abdul-Rahman A; Elamin, Sarra
2014-01-01
Central vein stenosis (CVS) is a common complication of central venous catheter (CVC) insertion. In this study we evaluated the prevalence and risk factors of CVS among hemodialysis (HD) patients in a single center in Sudan, using Doppler ultrasound as a screening tool. The study included 106 prevalent HD patients. For every patient, we performed Duplex Doppler for the right and left jugular, subclavian and femoral veins. A patient was considered to have hemodynamically significant stenosis if the pre-stenosis to the post-stenosis velocities ratio was ≥ 2.5 or they had complete vein occlusion. Overall, 28.3% of patients had Doppler detected CVS, including 25.5% with hemodynamically significant stenosis and 2.8% with compromised flow. The prevalence of CVS was 68.4% among symptomatic patients compared to 19.5% in asymptomatic patients. The prevalence of CVS among patients with history of 0-1, 2-3 and ≥ 4 central venous catheters was 3.4%, 29.4% and 53.8% respectively (p=0.00). CVS was not more common in patients with history of previous/current jugular or femoral vein catheterization compared to no catheter placement in these veins (28.3% vs 28.6% and 35% vs 26.7% respectively; p >0.1). However, CVS was significantly more common in patients with previous/ current subclavian vein catheterization compared to no catheter placement in this vein (47.8% vs 22.9%, p = 0.02). CVS is highly prevalent among studied HD patients, particularly in the presence of suggestive clinical signs. The number of HD catheter placements and subclavian vein utilization for dialysis access impose a significantly higher risk of CVS.
NASA Astrophysics Data System (ADS)
Blums, Angela
The present study examines instructional approaches and cognitive factors involved in elementary school children's thinking and learning the Control of Variables Strategy (CVS), a critical aspect of scientific reasoning. Previous research has identified several features related to effective instruction of CVS, including using a guided learning approach, the use of self-reflective questions, and learning in individual and group contexts. The current study examined the roles of procedural and conceptual instruction in learning CVS and investigated the role of executive function in the learning process. Additionally, this study examined how learning to identify variables is a part of the CVS process. In two studies (individual and classroom experiments), 139 third, fourth, and fifth grade students participated in hands-on and paper and pencil CVS learning activities and, in each study, were assigned to either a procedural instruction, conceptual instruction, or control (no instruction) group. Participants also completed a series of executive function tasks. The study was carried out with two parts--Study 1 used an individual context and Study 2 was carried out in a group setting. Results indicated that procedural and conceptual instruction were more effective than no instruction, and the ability to identify variables was identified as a key piece to the CVS process. Executive function predicted ability to identify variables and predicted success on CVS tasks. Developmental differences were present, in that older children outperformed younger children on CVS tasks, and that conceptual instruction was slightly more effective for older children. Some differences between individual and group instruction were found, with those in the individual context showing some advantage over the those in the group setting in learning CVS concepts. Conceptual implications about scientific thinking and practical implications in science education are discussed.
Li, Yi; Yao, Ning; Chau, Henry Wai
2017-08-15
Reference crop evapotranspiration (ET o ) is a key parameter in field irrigation scheduling, drought assessment and climate change research. ET o uses key prescribed (or fixed or reference) land surface parameters for crops. The linear and nonlinear trends in different climatic variables (CVs) affect ET o change. This research aims to reveal how ET o responds after the related CVs were linearly and nonlinearly detrended over 1961-2013 in Xinjiang, China. The ET o -related CVs included minimum (T min ), average (T ave ), and maximum air temperatures (T max ), wind speed at 2m (U 2 ), relative humidity (RH) and sunshine hour (n). ET o was calculated using the Penman-Monteith equation. A total of 29 ET o scenarios, including the original scenario, 14 scenarios in Group I (ET o was recalculated after removing linear trends from single or more CVs) and 14 scenarios in Group II (ET o was recalculated after removing nonlinear trends from the CVs), were generated. The influence of U 2 was stronger than influences of the other CVs on ET o for both Groups I and II either in northern, southern or the entirety of Xinjiang. The weak influences of increased T min , T ave and T max on increasing ET o were masked by the strong effects of decreased U 2 &n and increased RH on decreasing ET o . The effects of the trends in CVs, especially U 2 , on changing ET o were clearly shown. Without the general decreases of U 2 , ET o would have increased in the past 53years. Due to the non-monotone variations of the CVs and ET o , the results of nonlinearly detrending CVs on changing ET o in Group II should be more plausible than the results of linearly detrending CVs in Group I. The decreasing ET o led to a general relief in drought, which was indicated by the recalculated aridity index. Therefore, there would be a slightly lower risk of water utilization in Xinjiang, China. Copyright © 2017 Elsevier B.V. All rights reserved.
Evaluating cloudiness in an AGCM with Cloud Vertical Structure classes and their radiative effects
NASA Astrophysics Data System (ADS)
Lee, D.; Cho, N.; Oreopoulos, L.; Barahona, D.
2017-12-01
Clouds are recognized not only as the main modulator of Earth's Radiation Budget but also as the atmospheric constituent carrying the largest uncertainty in future climate projections. The presentation will showcase a new framework for evaluating clouds and their radiative effects in Atmospheric Global Climate Models (AGCMs) using Cloud Vertical Structure (CVS) classes. We take advantage of a new CVS reference dataset recently created from CloudSat's 2B-CLDCLASS-LIDAR product and which assigns observed cloud vertical configurations to nine simplified CVS classes based on cloud co-occurrence in three standard atmospheric layers. These CVS classes can also be emulated in GEOS-5 using the subcolumn cloud generator currently paired with the RRTMG radiation package as an implementation of the McICA scheme. Comparisons between the observed and modeled climatologies of the frequency of occurrence of the various CVS classes provide a new vantage point for assessing the realism of GEOS-5 clouds. Furthermore, a comparison between observed and modeled cloud radiative effects according to their CVS is also possible thanks to the availability of CloudSat's 2B-FLXHR-LIDAR product and our ability to composite radiative fluxes by CVS class - both in the observed and modeled realm. This latter effort enables an investigation of whether the contribution of the various CVS classes to the Earth's radiation budget is represented realistically in GEOS-5. Making this new pathway of cloud evaluation available to the community is a major step towards the improved representation of clouds in climate models.
Computer vision syndrome: a study of knowledge and practices in university students.
Reddy, S C; Low, C K; Lim, Y P; Low, L L; Mardina, F; Nursaleha, M P
2013-01-01
Computer vision syndrome (CVS) is a condition in which a person experiences one or more of eye symptoms as a result of prolonged working on a computer. To determine the prevalence of CVS symptoms, knowledge and practices of computer use in students studying in different universities in Malaysia, and to evaluate the association of various factors in computer use with the occurrence of symptoms. In a cross sectional, questionnaire survey study, data was collected in college students regarding the demography, use of spectacles, duration of daily continuous use of computer, symptoms of CVS, preventive measures taken to reduce the symptoms, use of radiation filter on the computer screen, and lighting in the room. A total of 795 students, aged between 18 and 25 years, from five universities in Malaysia were surveyed. The prevalence of symptoms of CVS (one or more) was found to be 89.9%; the most disturbing symptom was headache (19.7%) followed by eye strain (16.4%). Students who used computer for more than 2 hours per day experienced significantly more symptoms of CVS (p=0.0001). Looking at far objects in-between the work was significantly (p=0.0008) associated with less frequency of CVS symptoms. The use of radiation filter on the screen (p=0.6777) did not help in reducing the CVS symptoms. Ninety percent of university students in Malaysia experienced symptoms related to CVS, which was seen more often in those who used computer for more than 2 hours continuously per day. © NEPjOPH.
Exploratory Spectroscopy of Magnetic Cataclysmic Variables Candidates and Other Variable Objects
NASA Astrophysics Data System (ADS)
Oliveira, A. S.; Rodrigues, C. V.; Cieslinski, D.; Jablonski, F. J.; Silva, K. M. G.; Almeida, L. A.; Rodríguez-Ardila, A.; Palhares, M. S.
2017-04-01
The increasing number of synoptic surveys made by small robotic telescopes, such as the photometric Catalina Real-Time Transient Survey (CRTS), provides a unique opportunity to discover variable sources and improves the statistical samples of such classes of objects. Our goal is the discovery of magnetic Cataclysmic Variables (mCVs). These are rare objects that probe interesting accretion scenarios controlled by the white-dwarf magnetic field. In particular, improved statistics of mCVs would help to address open questions on their formation and evolution. We performed an optical spectroscopy survey to search for signatures of magnetic accretion in 45 variable objects selected mostly from the CRTS. In this sample, we found 32 CVs, 22 being mCV candidates, 13 of which were previously unreported as such. If the proposed classifications are confirmed, it would represent an increase of 4% in the number of known polars and 12% in the number of known IPs. A fraction of our initial sample was classified as extragalactic sources or other types of variable stars by the inspection of the identification spectra. Despite the inherent complexity in identifying a source as an mCV, variability-based selection, followed by spectroscopic snapshot observations, has proved to be an efficient strategy for their discoveries, being a relatively inexpensive approach in terms of telescope time. Based on observations obtained at the Observatório do Pico dos Dias/LNA, and at the Southern Astrophysical Research (SOAR) telescope, which is a joint project of the Ministério da Ciência, Tecnologia, e Inovação (MCTI) da República Federativa do Brasil, the U.S. National Optical Astronomy Observatory (NOAO), the University of North Carolina at Chapel Hill (UNC), and Michigan State University (MSU).
Haldar, Susanta; Kührová, Petra; Banáš, Pavel; Spiwok, Vojtěch; Šponer, Jiří; Hobza, Pavel; Otyepka, Michal
2015-08-11
RNA hairpins capped by 5'-GNRA-3' or 5'-UNCG-3' tetraloops (TLs) are prominent RNA structural motifs. Despite their small size, a wealth of experimental data, and recent progress in theoretical simulations of their structural dynamics and folding, our understanding of the folding and unfolding processes of these small RNA elements is still limited. Theoretical description of the folding and unfolding processes requires robust sampling, which can be achieved by either an exhaustive time scale in standard molecular dynamics simulations or sophisticated enhanced sampling methods, using temperature acceleration or biasing potentials. Here, we study structural dynamics of 5'-GNRA-3' and 5'-UNCG-3' TLs by 15-μs-long standard simulations and a series of well-tempered metadynamics, attempting to accelerate sampling by bias in a few chosen collective variables (CVs). Both methods provide useful insights. The unfolding and refolding mechanisms of the GNRA TL observed by well-tempered metadynamics agree with the (reverse) folding mechanism suggested by recent replica exchange molecular dynamics simulations. The orientation of the glycosidic bond of the GL4 nucleobase is critical for the UUCG TL folding pathway, and our data strongly support the hypothesis that GL4-anti forms a kinetic trap along the folding pathway. Along with giving useful insight, our study also demonstrates that using only a few CVs apparently does not capture the full folding landscape of the RNA TLs. Despite using several sophisticated selections of the CVs, formation of the loop appears to remain a hidden variable, preventing a full convergence of the metadynamics. Finally, our data suggest that the unfolded state might be overstabilized by the force fields used.
Zhao, Ming; Nian, Yingqun; Allen, Paul; Downey, Gerard; Kerry, Joseph P; O'Donnell, Colm P
2018-05-01
This work aims to develop a rapid analytical technique to predict beef sensory attributes using Raman spectroscopy (RS) and to investigate correlations between sensory attributes using chemometric analysis. Beef samples (n = 72) were obtained from young dairy bulls (Holstein-Friesian and Jersey×Holstein-Friesian) slaughtered at 15 and 19 months old. Trained sensory panel evaluation and Raman spectral data acquisition were both carried out on the same longissimus thoracis muscles after ageing for 21 days. The best prediction results were obtained using a Raman frequency range of 1300-2800 cm -1 . Prediction performance of partial least squares regression (PLSR) models developed using all samples were moderate to high for all sensory attributes (R 2 CV values of 0.50-0.84 and RMSECV values of 1.31-9.07) and were particularly high for desirable flavour attributes (R 2 CVs of 0.80-0.84, RMSECVs of 4.21-4.65). For PLSR models developed on subsets of beef samples i.e. beef of an identical age or breed type, significant improvements on prediction performances were achieved for overall sensory attributes (R 2 CVs of 0.63-0.89 and RMSECVs of 0.38-6.88 for each breed type; R 2 CVs of 0.52-0.89 and RMSECVs of 0.96-6.36 for each age group). Chemometric analysis revealed strong correlations between sensory attributes. Raman spectroscopy combined with chemometric analysis was demonstrated to have high potential as a rapid and non-destructive technique to predict the sensory quality traits of young dairy bull beef. Copyright © 2018. Published by Elsevier Ltd.
Rosado, T; Fernandes, L; Barroso, M; Gallardo, E
2017-02-01
Cannabis is one of the most available and consumed illicit drug in the world and its identification and quantification in biological specimens can be a challenge given its low concentrations in body fluids. The present work describes a fast and fully validated procedure for the simultaneous detection and quantification of ▵ 9 -tetrahydrocannabinol (▵ 9_ THC) and its two main metabolites 11-hydroxy ▵ 9_ tetrahydrocannabinol (11-OH-THC) and 11-nor-9-carboxy-▵ 9 - tetrahydrocannbinol (THC-COOH) in plasma samples using microextraction by packed sorbent (MEPS) and gas chromatography-tandem mass spectrometry (GC-MS/MS). A small plasma volume (0.25mL) pre-diluted (1:20), was extracted with MEPS M1 sorbent as follows: conditioning (4 cycles of 250μL methanol and 4 cycles of 250μL 0.1% formic acid in water); sample load (26 cycles of 250μL); wash (100μL of 3% acetic acid in water followed by 100μL 5% methanol in water); and elution (6 cycles of 100μL of 10% ammonium hydroxide in methanol). The procedure allowed the quantification of all analytes in the range of 0.1-30ng/mL. Recoveries ranged from 53 to 78% (THC), 57 to 66% (11-OH-THC) and 62 to 65% (THC-COOH), allowing the limits of detection and quantification to be set at 0.1ng/mL for all compounds. Intra-day precision and accuracy revealed coefficients of variation (CVs) lower than 10% at the studied concentrations, with a mean relative error within±9%, while inter-day precision and accuracy showed CVs lower than 15% for all analytes at the tested concentrations, with an inaccuracy within±8%. Copyright © 2016 Elsevier B.V. All rights reserved.
Neuroendocrine and oxidoreductive mechanisms of stress-induced cardiovascular diseases.
Pajović, S B; Radojcić, M B; Kanazir, D T
2008-01-01
The review concerns a number of basic molecular pathways that play a crucial role in perception, transmission, and modulation of the stress signals, and mediate the adaptation of the vital processes in the cardiovascular system (CVS). These highly complex systems for intracellular transfer of information include stress hormones and their receptors, stress-activated phosphoprotein kinases, stress-activated heat shock proteins, and antioxidant enzymes maintaining oxidoreductive homeostasis of the CVS. Failure to compensate for the deleterious effects of stress may result in the development of different pathophysiological states of the CVS, such as ischemia, hypertension, atherosclerosis and infarction. Stress-induced dysbalance in each of the CVS molecular signaling systems and their contribution to the CVS malfunctioning is reviewed. The general picture of the molecular mechanisms of the stress-induced pathophysiology in the CVS pointed out the importance of stress duration and intensity as etiological factors, and suggested that future studies should be complemented by the careful insights into the individual factors of susceptibility to stress, prophylactic effects of 'healthy' life styles and beneficial action of antioxidant-rich nutrition.
Smith, Brittany L; Morano, Rachel L; Ulrich-Lai, Yvonne M; Myers, Brent; Solomon, Matia B; Herman, James P
2017-11-22
The late adolescent period is characterized by marked neurodevelopmental and endocrine fluctuations in the transition to early adulthood. Adolescents are highly responsive to the external environment, which enhances their ability to adapt and recover from challenges when given nurturing influences, but also makes them vulnerable to aberrant development when exposed to prolonged adverse situations. Female rats are particularly sensitive to the effects of chronic stress in adolescence, which manifests as passive coping strategies and blunted hypothalamo-pituitary adrenocortical (HPA) stress responses in adulthood. We sought to intervene by exposing adolescent rats to environmental enrichment (EE) immediately prior to and during chronic stress, hypothesizing that EE would minimize or prevent the long-term effects of stress that emerge in adult females. To test this, we exposed male and female rats to EE on postnatal days (PND) 33-60 and implemented chronic variable stress (CVS) on PND 40-60. CVS consisted of twice-daily unpredictable stressors. Experimental groups included: CVS/unenriched, unstressed/EE, CVS/EE and unstressed/unenriched (n = 10 of each sex/group). In adulthood, we measured behavior in the open field test and forced swim test (FST) and collected blood samples following the FST. We found that environmental enrichment given during the adolescent period prevented the chronic stress-induced transition to passive coping in the FST and reversed decreases in peak adrenocortical responsiveness observed in adult females. Adolescent enrichment had little to no effect on males or unstressed females tested in adulthood, indicating that beneficial effects are specific to females that were exposed to chronic stress.
Parvari, R; Hershkovitz, E; Carmi, R; Moses, S
1996-09-01
Glycogen storage disease type 1a (GSD 1a), a severe metabolic disorder, is caused by the absence of glucose-6-phosphatase (G6Pase) activity. Diagnosis is currently established by demonstrating the lack of G6Pase activity in the patient's liver specimen. Enzymatic diagnosis cannot be performed in chorionic villi or amniocytes as G6Pase is active only in the liver, kidney, and intestinal mucosa. Recent cloning of the G6Pase gene and subsequent identification of the mutations causing GSD 1a have led to the possibility of performing DNA-based diagnosis in chorionic villus samples (CVS) or amniocytes. Here we report the first DNA-based prenatal diagnosis in two families in whom GSD 1a patients were diagnosed. In one Jewish family with a previously identified R83C mutation, single-stranded conformation polymorphism (SSCP) analysis of the DNA extracted from CVS showed a homozygous R83C mutant pattern. As a result, the pregnancy was terminated and the diagnosis was confirmed on DNA analysis of the aborted fetus. In another family of Arabic extraction in which a V166G mutation has been identified in one of the siblings, SSCP analysis performed on DNA extracted from CVS presented the pattern of a normal control. The pregnancy was carried to term and a healthy baby was born. Thus, once mutations causing the disease are identified, prenatal diagnosis of GSD 1a is possible. SSCP analysis of DNA prepared from CVS is reliable, simple and fast, making it a suitable method for prenatal diagnosis.
NASA Astrophysics Data System (ADS)
Belloni, Diogo; Zorotovic, Mónica; Schreiber, Matthias R.; Leigh, Nathan W. C.; Giersz, Mirek; Askar, Abbas
2017-06-01
In this third of a series of papers related to cataclysmic variables (CVs) and related objects, we analyse the population of CVs in a set of 12 globular cluster models evolved with the MOCCA Monte Carlo code, for two initial binary populations (IBPs), two choices of common-envelope phase (CEP) parameters, and three different models for the evolution of CVs and the treatment of angular momentum loss. When more realistic models and parameters are considered, we find that present-day cluster CV duty cycles are extremely low (≲0.1 per cent) that makes their detection during outbursts rather difficult. Additionally, the IBP plays a significant role in shaping the CV population properties, and models that follow the Kroupa IBP are less affected by enhanced angular momentum loss. We also predict from our simulations that CVs formed dynamically in the past few Gyr (massive CVs) correspond to bright CVs (as expected) and that faint CVs formed several Gyr ago (dynamically or not) represent the overwhelming majority. Regarding the CV formation rate, we rule out the notion that it is similar irrespective of the cluster properties. Finally, we discuss the differences in the present-day CV properties related to the IBPs, the initial cluster conditions, the CEP parameters, formation channels, the CV evolution models and the angular momentum loss treatments.
NASA Astrophysics Data System (ADS)
Giorgino, Toni; Laio, Alessandro; Rodriguez, Alex
2017-08-01
Molecular dynamics (MD) simulations allow the exploration of the phase space of biopolymers through the integration of equations of motion of their constituent atoms. The analysis of MD trajectories often relies on the choice of collective variables (CVs) along which the dynamics of the system is projected. We developed a graphical user interface (GUI) for facilitating the interactive choice of the appropriate CVs. The GUI allows: defining interactively new CVs; partitioning the configurations into microstates characterized by similar values of the CVs; calculating the free energies of the microstates for both unbiased and biased (metadynamics) simulations; clustering the microstates in kinetic basins; visualizing the free energy landscape as a function of a subset of the CVs used for the analysis. A simple mouse click allows one to quickly inspect structures corresponding to specific points in the landscape.
Does tidal capture produce cataclysmic variables?
NASA Technical Reports Server (NTRS)
Bailyn, Charles D.; Grindlay, Jonathan E.; Garcia, Michael R.
1990-01-01
It is shown that earlier estimates of the number of cataclysmic variables (CVs) to be expected from tidal capture in globular clusters may have been considerably too high, since many such binaries will result in unstable mass transfer, and thus not become CVs after all. In particular, CVs with white dwarf masses less than or obout 1.0 solar mass will be supressed. Such unstable mass transfer events may produce some of the cluster mass loss required to stabilize the cluster core. The smaller number of stable CVs predicted may suggest a reconsideration of the nature of some of the low-luminosity cluster X-ray sources.
Performance evaluation of BC-3200 hematology analyzer in a university hospital.
Peng, L; Bai, L; Nie, L; Wu, Z; Yan, C
2008-06-01
The BC-3200 automated hematology analyzer was evaluated and compared with the Beckman-Coulter AcT (Ac.T diff 2) 3-part differential hematology analyzer. The BC-3200 was evaluated according to guidelines published by the International Committee for Standardization in Hematology (ICSH), Clinical and Laboratory Standards Institute (CLSI), and Department of Food and Drug Administration (FDA). The results demonstrated no background, minimal carryover (<0.5%), and excellent linearity for hemoglobin (Hb) level, white blood cell (WBC), red blood cell (RBC), and platelet (PLT) counts (>0.998). Precision was generally acceptable for all complete blood count (CBC) parameters; coefficients of variation (CVs) were within the manufacturer's claims and CVs of CBC parameters, including WBC, RBC and PLT counts, Hb and mean corpuscular volume, were <6%. Correlation between the BC-3200 and Ac.T diff 2 was excellent (r > 0.98) for all major CBC parameters (WBC, RBC, and PLT counts and Hb). We conclude that the overall performance of the BC-3200 is excellent and compares well with that of the Coulter Ac.T diff 2.
The significance of the psychosocial factors influence in pathogenesis of cardiovascular disease.
Masic, Izet; Alajbegovic, Jasmin
2013-11-01
Cardiovascular diseases (CVD) are the leading cause of death in the world today. Risk factors are those factors that influence the development of CVD. Risk factors can be divided into materialistic (genetic predisposition, smoking, alcohol) and non-materialistic (psychosocial factors). Our goal is to note the role of the health system, to emphasize the importance of psychosocial factors in the pathogenesis of CVD, explain the relationship between psychosocial factors and other risk factors, stress the importance of prevention through the provision of management of the cardiovascular system (CVS) diseases. A DESCRIPTIVE ANALYSIS WAS PERFORMED ON SCIENTIFIC STUDIES IN SEVERAL PUBLISHED ARTICLES IN JOURNALS ON CVS: Public Health Reviews, CVD, European Heart Journal, Materia Socio Medica and other indexed journals that publish articles on CVS. THE IMPORTANCE AND ROLE OF THE HEALTH SYSTEM IN THE EARLY DETECTION, DIAGNOSIS, THERAPY AND CVS DISEASE PREVENTION IS PRESENTED THROUGH THREE THEMATIC AREAS: (a) The incidence and prevalence of CVS diseases; (b) treatment of CVS diseases and (c) promotion of health in patients with CVS disease and those the risk of their occurrence. Health promotion is the most important aspect of the health system monitoring. Health promotion is adequately implemented ifthe management ofCVD is proper. The main objectives of CVD management are: Preventing or delaying the occurrence of CVD, reducing the number and severity of worsening and complications of CVD. Management Includes: Individual and family, the health system and the community. Materialistic and non-materialistic risk factors together contribute to the development of CVD.
Peters, A Michael; Howard, Bethany; Neilly, Mark D J; Seshadri, Nagabhushan; Sobnack, Ravin; Hooker, Claire A; Irwin, Andrew; Snelling, Hayley; Gruning, Thomas; Perry, Laura; Patel, Neva H; Lawson, Richard S; Shabo, Gregory; Williams, Nigel; Dave, Surendra; Barnfield, Mark C
2012-04-01
The objective of the study was to undertake a clinical audit of departmental performance in the measurement of glomerular filtration rate (GFR) using the coefficient of variation (CV) of extracellular fluid volume (ECFV) as the benchmark. ECFV is held within narrow limits in healthy subjects, narrower than GFR, and should therefore have a low CV. Fifteen departments participated in this retrospective study of healthy renal transplant donors. Data were analysed separately for men (n ranged from 28 to 115 per centre; total = 819) and women (n = 28-146; 1,059). All centres used the slope-intercept method with blood sample numbers ranging from two to five. Subjects did not fast prior to GFR measurement. GFR was scaled to body surface area (BSA) and corrected for the single compartment assumption. GFR scaled to ECFV was calculated as the terminal slope rate constant and corrected for the single compartment assumption. ECFV/BSA was calculated as the ratio of GFR/BSA to GFR/ECFV. The departmental CVs of ECFV/BSA and GFR/BSA ranged from 8.3 to 25.8% and 12.8 to 21.9%, respectively, in men, and from 9.6 to 21.1% and 14.8 to 23.7%, respectively, in women. Both CVs correlated strongly between men and women from the same centre, suggesting department-specific systematic errors. GFR/BSA was higher in men in 14 of 15 centres, whereas GFR/ECFV was higher in women in 14 of 15 centres. Both correlated strongly between men and women, suggesting regional variation in GFR. The CV of ECFV/BSA in normal subjects is a useful indicator of the technical robustness with which GFR is measured and, in this study, indicated a wide variation in departmental performance.
40 CFR 90.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2012 CFR
2012-07-01
... detector (HFID) for the measurement of hydrocarbons, non-dispersive infrared analyzers (NDIR) for the... converted to nitric oxide before analysis. Other types of analyzers may be used if shown to yield equivalent... room temperature, produces an equivalent CO response, as measured on the most sensitive CO range, which...
40 CFR 90.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2010 CFR
2010-07-01
... detector (HFID) for the measurement of hydrocarbons, non-dispersive infrared analyzers (NDIR) for the... converted to nitric oxide before analysis. Other types of analyzers may be used if shown to yield equivalent... room temperature, produces an equivalent CO response, as measured on the most sensitive CO range, which...
40 CFR 90.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2014 CFR
2014-07-01
... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS... detector (HFID) for the measurement of hydrocarbons, non-dispersive infrared analyzers (NDIR) for the... converted to nitric oxide before analysis. Other types of analyzers may be used if shown to yield equivalent...
40 CFR 90.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19... detector (HFID) for the measurement of hydrocarbons, non-dispersive infrared analyzers (NDIR) for the... converted to nitric oxide before analysis. Other types of analyzers may be used if shown to yield equivalent...
40 CFR 90.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19... detector (HFID) for the measurement of hydrocarbons, non-dispersive infrared analyzers (NDIR) for the... converted to nitric oxide before analysis. Other types of analyzers may be used if shown to yield equivalent...
Processing of Communication Sounds: Contributions of Learning, Memory, and Experience
Bigelow, James; Rossi, Breein
2013-01-01
Abundant evidence from both field and lab studies has established that conspecific vocalizations (CVs) are of critical ecological significance for a wide variety of species, including humans, nonhuman primates, rodents, and other mammals and birds. Correspondingly, a number of experiments have demonstrated behavioral processing advantages for CVs, such as in discrimination and memory tasks. Further, a wide range of experiments have described brain regions in many species that appear to be specialized for processing CVs. For example, several neural regions have been described in both mammals and birds wherein greater neural responses are elicited by CVs than by comparison stimuli such as heterospecific vocalizations, nonvocal complex sounds, and artificial stimuli. These observations raise the question of whether these regions reflect domain-specific neural mechanisms dedicated to processing CVs, or alternatively, if these regions reflect domain-general neural mechanisms for representing complex sounds of learned significance. Inasmuch as CVs can be viewed as complex combinations of basic spectrotemporal features, the plausibility of the latter position is supported by a large body of literature describing modulated cortical and subcortical representation of a variety of acoustic features that have been experimentally associated with stimuli of natural behavioral significance (such as food rewards). Herein, we review a relatively small body of existing literature describing the roles of experience, learning, and memory in the emergence of species-typical neural representations of CVs and auditory system plasticity. In both songbirds and mammals, manipulations of auditory experience as well as specific learning paradigms are shown to modulate neural responses evoked by CVs, either in terms of overall firing rate or temporal firing patterns. In some cases, CV-sensitive neural regions gradually acquire representation of non-CV stimuli with which subjects have training and experience. These results parallel literature in humans describing modulation of responses in face-sensitive neural regions through learning and experience. Thus, although many questions remain, the available evidence is consistent with the notion that CVs may acquire distinct neural representation through domain-general mechanisms for representing complex auditory objects that are of learned importance to the animal. PMID:23792078
Garne, Ester; Loane, Maria; de Vigan, Catherine; Scarano, Gioacchino; de Walle, Hermien; Gillerot, Yves; Stoll, Claude; Addor, Marie-Claude; Stone, David; Gener, Blanca; Feijoo, Maria; Mosquera-Tenreiro, Carmen; Gatt, Miriam; Queisser-Luft, Annette; Baena, Neus; Dolk, Helen
2004-11-01
To investigate outcomes of ultrasound investigations (US) and invasive diagnostic procedures in cases of congenital malformations (CM), and to compare the use of invasive prenatal test techniques (amniocentesis (AC) versus chorionic villus sampling (CVS)) among European populations. Analysis of data from population-based registries of CM. 25 400 cases of CM recorded by 14 EUROCAT registries covering a total population of 1,013,352 births 1995-99. US were performed in 91% of cases, and positively detected CM in 35% of cases. AC was performed in 24% of the cases and CVS in 3% of cases. Thirty-eight percent of invasive tests gave positive results. Fifty-two percent of cases with maternal age > or = 35 years had an invasive test performed compared to 20% of cases with younger mothers. Considerable variation was found between registries in the uptake rate of invasive tests in cases with older maternal age and on the use of invasive tests with only four regions employing CVS techniques in at least a third of the cases having invasive tests. For chromosomal anomalies US gave positive results in 46% of cases with maternal age < 35 years with US performed and in 36% of cases with maternal age > or = 35 years with US performed. Prenatal US was performed in 91% of all pregnancies with CM but the test was only positive in a third of the cases. There was large regional variation in the uptake rate of invasive tests with maternal age of 35 years or more. For every CVS carried out there were nine AC tests. US is an important tool in the prenatal diagnosis of chromosomal anomalies in Europe. Copyright 2004 John Wiley & Sons, Ltd.
Petäjä, Tiina; Pedersen, Court; Poder, Airi; Strauss, Gitte; Catteau, Gregory; Thomas, Florence; Lehtinen, Matti; Descamps, Dominique
2011-11-01
Vaccination against oncogenic human papillomavirus (HPV) types is one key intervention for cervical cancer prevention. This follow-up study assessed the persistence of the systemic and mucosal immune responses together with the safety profile of the HPV-16/18 AS04-adjuvanted vaccine administered to young women aged 10-25 years. Serum and cervicovaginal secretion (CVS) samples were collected at prespecified time-points during the 48-month follow-up period. Anti-HPV-16/18 antibody levels in serum and CVS were measured by enzyme-linked immunosorbent assay (ELISA). At Month 48, all subjects remained seropositive for serum anti-HPV-16 and -18 antibodies. As previously observed, anti-HPV-16 and -18 antibodies levels (ELISA Units/mL) were higher in subjects vaccinated at the age of 10-14 years (2862.2 and 940.8) compared to subjects vaccinated at the age of 15-25 years (1186.2 and 469.8). Moreover, anti-HPV-16 and -18 antibodies in CVS were still detectable for subjects aged 15-25 years (84.1% and 69.7%, respectively). There was a strong correlation between serum and CVS anti-HPV-16 and -18 antibodies levels (correlation coefficients = 0.84 and 0.90 at Month 48, respectively) supporting the hypothesis of transudation or exudation of serum immunoglobulin G antibodies through the cervical epithelium. The HPV-16/18 AS04-adjuvanted vaccine had a clinically acceptable safety profile. In conclusion, this follow-up study shows that the HPV-16/18 AS04-adjuvanted vaccine administered to preteen/adolescents girls and young women induces long-term systemic and mucosal immune response and has a clinically acceptable safety profile up to 4 years after the first vaccine dose. Copyright © 2010 UICC.
Occult central venous stenosis leading to airway obstruction after subtotal parathyroidectomy.
Meiklejohn, Duncan A; Chan, Dylan K; Lalakea, M Lauren
2016-07-01
Subtotal parathyroidectomy may be indicated in patients with chronic renal failure and tertiary hyperparathyroidism, a population at increased risk for central venous stenosis (CVS) due to repeated vascular access. Here we report a case of complete upper airway obstruction precipitated by subtotal parathyroidectomy with ligation of anterior jugular vein collaterals in a patient with occult CVS. This case demonstrates a previously unreported risk of anterior neck surgery in patients with chronic renal failure. We present a review of the literature and discuss elements of the history and physical examination suggestive of occult CVS, with additional workup proposed for appropriate cases. Recommendations are discussed for perioperative and postoperative care in patients at increased risk for CVS.
Sampling free energy surfaces as slices by combining umbrella sampling and metadynamics.
Awasthi, Shalini; Kapil, Venkat; Nair, Nisanth N
2016-06-15
Metadynamics (MTD) is a very powerful technique to sample high-dimensional free energy landscapes, and due to its self-guiding property, the method has been successful in studying complex reactions and conformational changes. MTD sampling is based on filling the free energy basins by biasing potentials and thus for cases with flat, broad, and unbound free energy wells, the computational time to sample them becomes very large. To alleviate this problem, we combine the standard Umbrella Sampling (US) technique with MTD to sample orthogonal collective variables (CVs) in a simultaneous way. Within this scheme, we construct the equilibrium distribution of CVs from biased distributions obtained from independent MTD simulations with umbrella potentials. Reweighting is carried out by a procedure that combines US reweighting and Tiwary-Parrinello MTD reweighting within the Weighted Histogram Analysis Method (WHAM). The approach is ideal for a controlled sampling of a CV in a MTD simulation, making it computationally efficient in sampling flat, broad, and unbound free energy surfaces. This technique also allows for a distributed sampling of a high-dimensional free energy surface, further increasing the computational efficiency in sampling. We demonstrate the application of this technique in sampling high-dimensional surface for various chemical reactions using ab initio and QM/MM hybrid molecular dynamics simulations. Further, to carry out MTD bias reweighting for computing forward reaction barriers in ab initio or QM/MM simulations, we propose a computationally affordable approach that does not require recrossing trajectories. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Minati, Ludovico; Visani, Elisa; Dowell, Nick G; Medford, Nick; Critchley, Hugo D
2011-01-01
Brain near-infrared spectroscopy (NIRS) is emerging as a potential alternative to functional MRI (fMRI). To date, no study has explicitly compared the two techniques in terms of measurement variability, a key parameter dictating attainable statistical power. Here, NIRS and fMRI were simultaneously recorded during event-related visual stimulation. Inter-subject coefficients of variation (CVs) for peak response amplitude were considerably larger for NIRS than fMRI, but inter-subject CVs for response latency and intra-subject CVs for response amplitude were overall comparable. Our results may represent an optimistic estimate of the CVs of NIRS measurements, as optode positioning was guided by structural MRI, which is normally unavailable. We conclude that fMRI may be preferable to NIRS for group comparisons, but NIRS is equally powerful when comparing conditions within participants. The discrepancy between inter- and intra-subject CVs is likely related to variability in head anatomy and tissue properties which may be better accounted for by emerging NIRS technology. PMID:21780948
ERIC Educational Resources Information Center
Jacobsen, Nancy M.
2009-01-01
This dissertation explores the private-public sector partnership between CVS/pharmacy and the federal/state workforce development system in Minnesota. The study describes how CVS creates partnerships with the federal/state system of one-stop career centers and other partners in the workforce development arena such as community or faith-based…
Jung, Sungwook; Park, Joonhyuck; Bang, Jiwon; Kim, Jae-Yeol; Kim, Cheolhee; Jeon, Yongmoon; Lee, Seung Hwan; Jin, Ho; Choi, Sukyung; Kim, Bomi; Lee, Woo Jin; Pack, Chan-Gi; Lee, Jong-Bong; Lee, Nam Ki; Kim, Sungjee
2017-06-07
Photoswitching or modulation of quantum dots (QDs) can be promising for many fields that include display, memory, and super-resolution imaging. However, such modulations have mostly relied on photomodulations of conjugated molecules in QD vicinity, which typically require high power of high energy photons at UV. We report a visible light-induced facile modulation route for QD-dye conjugates. QD crystal violets conjugates (QD-CVs) were prepared and the crystal violet (CV) molecules on QD quenched the fluorescence efficiently. The fluorescence of QD-CVs showed a single cycle of emission burst as they go through three stages of (i) initially quenched "off" to (ii) photoactivated "on" as the result of chemical change of CVs induced by photoelectrons from QD and (iii) back to photodarkened "off" by radical-associated reactions. Multicolor on-demand photopatterning was demonstrated using QD-CV solid films. QD-CVs were introduced into cells, and excitation with visible light yielded photomodulation from "off" to "on" and "off" by nearly ten fold. Individual photoluminescence dynamics of QD-CVs was investigated using fluorescence correlation spectroscopy and single QD emission analysis, which revealed temporally stochastic photoactivations and photodarkenings. Exploiting the stochastic fluorescence burst of QD-CVs, simultaneous multicolor super-resolution localizations were demonstrated.
Ibrahim, I K; Lewis, S A; Harshman, D C
1993-12-01
Twenty-two graminaceous plant cultivars were evaluated in the greenhouse for host suitability for three South Carolina isolates of Meloidogyne arenaria race 2 (Ma-R2) designated as Florence, Govan, and Pelion, a Florida isolate of M. arenaria race 1 (Ma-R1), and a South Carolina M. incognita race 3. Host suitability was determined by calculating egg mass index (EMI) reproduction factor (RF) (final egg numbers/initial egg numbers), and number of eggs per gram fresh root. Corn hybrids Pioneer 3147 and Northrup King 508 and oat cv. Florida 502 were nonhosts to all nematode isolates, as no egg masses or eggs were found in roots grown in infested soils. Oat cv. Coker 716 and grain sorghum cvs. Cherokee, Northrup King 2660, and Pioneer 8333 were poor hosts (RF < 1). Good (RF = 1.1-5.0) or excellent (RF > 5.0) hosts for both Ma-R1 and three Ma-R2 isolates included the following: barley cvs. Boone, Keowee, and Redhill; corn hybrid Pioneer 3389; oat cvs. Brooks and Coker 820; rye cvs. Bonel, Florida 401, and Wrens Abruzzi; triticale cvs. Beagle 82 and Florida 201 ; and wheat cvs. Coker 983, Florida 302, and Williams. All cultivars except Coker 716 oat were good or excellent hosts of M. incognita.
2012-01-01
Background Beyond the adoption of the principles of horizontal and vertical integration, significant planning and implementation of curriculum reform is needed. This study aimed to assess the effect of the interdisciplinary integrated Cardiovascular System (CVS) module on both student satisfaction and performance and comparing them to those of the temporally coordinated CVS module that was implemented in the previous year at the faculty of Medicine of the King Abdulaziz University, Saudi Arabia. Methods This interventional study used mixed method research design to assess student and faculty satisfaction with the level of integration within the CVS module. A team from the medical education department was assembled in 2010/2011 to design a plan to improve the CVS module integration level. After delivering the developed module, both student and faculty satisfaction as well as students performance were assessed and compared to those of the previous year to provide an idea about module effectiveness. Results Many challenges faced the medical education team during design and implementation of the developed CVS module e.g. resistance of faculty members to change, increasing the percentage of students directed learning hours from the total contact hour allotted to the module and shifting to integrated item writing in students assessment, spite of that the module achieved a significant increase in both teaching faculty and student satisfaction as well as in the module scores. Conclusion The fully integrated CVS has yielded encouraging results that individual teachers or other medical schools who attempt to reformulate their curriculum may find valuable. PMID:22747781
Vibroconvective mixing applied to vertical Bridgman growth
NASA Astrophysics Data System (ADS)
Zawilski, Kevin T.; Claudia, M.; Custodio, C.; DeMattei, Robert C.; Feigelson, Robert S.
2003-10-01
A promising method for stirring melts during vertical Bridgman growth is the coupled vibrational stirring (CVS) method. It involves the application of low frequency vibrations to the outside of the growth ampoule and produces strong flows emanating from the fluid surface. Although the technique was pioneered a number of years ago, previous studies have not provided sufficient information to explain how to control CVS generated flows in a particular system. This paper examines both the fluid flow produced by CVS and the effect of these flows on a model oxide growth system. CVS generated flows were studied using tracer particles in a water/glycerin system. The particle velocities were measured as a function of distance from the fluid surface. A large velocity gradient, decreasing from the surface, was found to be present. The velocity profile produced was dependent on the vibrational amplitude and frequency, the crucible diameter, and the fluid viscosity. The effects of CVS flows on the crystal growth interface were studied using NaNO 3 as a model oxide. Under non-growth conditions (i.e. no furnace or crucible translation), the solid-liquid interface position was found to be a strong function of vibrational frequency once CVS generated flows approached the interface. During crystal growth, undesirable growth rate fluctuations were found as the growth interface moved into regions of increasing fluid flow. This data suggests that a control system in which CVS flows are continuously decreased during growth to maintain a constant flow rate in the vicinity of the growth interface is necessary in order to prevent or reduce growth rate fluctuations.
Cannell, R C; Belk, K E; Tatum, J D; Wise, J W; Chapman, P L; Scanga, J A; Smith, G C
2002-05-01
Objective quantification of differences in wholesale cut yields of beef carcasses at plant chain speeds is important for the application of value-based marketing. This study was conducted to evaluate the ability of a commercial video image analysis system, the Computer Vision System (CVS) to 1) predict commercially fabricated beef subprimal yield and 2) augment USDA yield grading, in order to improve accuracy of grade assessment. The CVS was evaluated as a fully installed production system, operating on a full-time basis at chain speeds. Steer and heifer carcasses (n = 296) were evaluated using CVS, as well as by USDA expert and online graders, before the fabrication of carcasses into industry-standard subprimal cuts. Expert yield grade (YG), online YG, CVS estimated carcass yield, and CVS measured ribeye area in conjunction with expert grader estimates of the remaining YG factors (adjusted fat thickness, percentage of kidney-pelvic-heart fat, hot carcass weight) accounted for 67, 39, 64, and 65% of the observed variation in fabricated yields of closely trimmed subprimals. The dual component CVS predicted wholesale cut yields more accurately than current online yield grading, and, in an augmentation system, CVS ribeye measurement replaced estimated ribeye area in determination of USDA yield grade, and the accuracy of cutability prediction was improved, under packing plant conditions and speeds, to a level close to that of expert graders applying grades at a comfortable rate of speed offline.
The Significance of the Psychosocial Factors Influence in Pathogenesis of Cardiovascular Disease
Masic, Izet; Alajbegovic, Jasmin
2013-01-01
Background: Cardiovascular diseases (CVD) are the leading cause of death in the world today. Risk factors are those factors that influence the development of CVD. Risk factors can be divided into materialistic (genetic predisposition, smoking, alcohol) and non-materialistic (psychosocial factors). Our goal is to note the role of the health system, to emphasize the importance of psychosocial factors in the pathogenesis of CVD, explain the relationship between psychosocial factors and other risk factors, stress the importance of prevention through the provision of management of the cardiovascular system (CVS) diseases. Methods: A descriptive analysis was performed on scientific studies in several published articles in journals on CVS: Public Health Reviews, CVD, European Heart Journal, Materia Socio Medica and other indexed journals that publish articles on CVS. Results and Conclusions: The importance and role of the health system in the early detection, diagnosis, therapy and CVS disease prevention is presented through three thematic areas: (a) The incidence and prevalence of CVS diseases; (b) treatment of CVS diseases and (c) promotion of health in patients with CVS disease and those the risk of their occurrence. Health promotion is the most important aspect of the health system monitoring. Health promotion is adequately implemented ifthe management ofCVD is proper. The main objectives of CVD management are: Preventing or delaying the occurrence of CVD, reducing the number and severity of worsening and complications of CVD. Management Includes: Individual and family, the health system and the community. Materialistic and non-materialistic risk factors together contribute to the development of CVD. PMID:24404370
Birse, Kenzie D M; Cole, Amy L; Hirbod, Taha; McKinnon, Lyle; Ball, Terry B; Westmacott, Garrett R; Kimani, Joshua; Plummer, Frank; Cole, Alexander M; Burgener, Adam; Broliden, Kristina
2015-01-01
Cationic proteins found in cervicovaginal secretions (CVS) are known to contribute to the early antiviral immune response against HIV-infection in vitro. We here aimed to define additional antiviral factors that are over-expressed in CVS from female sex workers at high risk of infection. CVS were collected from Kenyan HIV-seronegative (n = 34) and HIV-seropositive (n = 12) female sex workers, and were compared with those from HIV-seronegative low-risk women (n = 12). The highly exposed seronegative (HESN) sex workers were further divided into those with less (n = 22) or more (n = 12) than three years of documented sex work. Cationic protein-depleted CVS were assessed for HIV-neutralizing activity by a PBMC-based HIV-neutralizing assay, and then characterized by proteomics. HIV neutralizing activity was detected in all unprocessed CVS, however only CVS from the female sex worker groups maintained its HIV neutralizing activity after cationic protein-depletion. Differentially abundant proteins were identified in the cationic protein-depleted secretions including 26, 42, and 11 in the HESN>3 yr, HESN<3 yr, and HIV-positive groups, respectively. Gene ontology placed these proteins into functional categories including proteolysis, oxidation-reduction, and epidermal development. The proteins identified in this study include proteins previously associated with the HESN phenotype in other cohorts as well as novel proteins not yet associated with anti-HIV activities. While cationic proteins appear to contribute to the majority of the intrinsic HIV neutralizing activity in the CVS of low-risk women, a broader range of non-cationic proteins were associated with HIV neutralizing activity in HESN and HIV-positive female sex workers. These results indicate that novel protein factors found in CVS of women with high-risk sexual practices may have inherent antiviral activity, or are involved in other aspects of anti-HIV host defense, and warrant further exploration into their mode of action.
Noninvasive prenatal testing: the future is now.
Norwitz, Errol R; Levy, Brynn
2013-01-01
Prenatal detection of chromosome abnormalities has been offered for more than 40 years, first by amniocentesis in the early 1970s and additionally by chorionic villus sampling (CVS) in the early 1980s. Given the well-recognized association between increasing maternal age and trisomy,1-3 the primary utilization of prenatal testing has been by older mothers. This has drastically reduced the incidence of aneuploid children born to older mothers.4 Although younger women have relatively low risks of conceiving a child with aneuploidy, the majority of pregnant women are in their late teens, 20s, and early 30s. As such, most viable aneuploid babies are born to these younger mothers.5 Invasive prenatal diagnosis (CVS and amniocentesis) is not a feasible option for all low-risk mothers, as these procedures carry a small but finite risk and would ultimately cause more miscarriages than they would detect aneuploidy. For this reason, a number of noninvasive tests have been developed-including first-trimester risk assessment at 11 to 14 weeks, maternal serum analyte (quad) screening at 15 to 20 weeks, and sonographic fetal structural survey at 18 to 22 weeks-all of which are designed to give a woman an adjusted (more accurate) estimate of having an aneuploid fetus using as baseline her a priori age-related risk. Ultrasound and maternal serum analysis are considered screening procedures and both require follow up by CVS or amniocentesis in screen-positive cases for a definitive diagnosis of a chromosome abnormality in the fetus. The ability to isolate fetal cells and fetal DNA from maternal blood during pregnancy has opened up exciting opportunities for improved noninvasive prenatal testing (NIPT). Direct analysis of fetal cells from maternal circulation has been challenging given the scarcity of fetal cells in maternal blood (1:10,000-1:1,000,000) and the focus has shifted to the analysis of cell-free fetal DNA, which is found at a concentration almost 25 times higher than that available from nucleated blood cells extracted from a similar volume of whole maternal blood. There have now been numerous reports on the use of cell-free DNA (cfDNA) for NIPT for chromosomal aneuploidies-especially trisomy (an extra copy of a chromosome) or monosomy (a missing chromosome)-and a number of commercial products are already being marketed for this indication. This article reviews the various techniques being used to analyze cell-free DNA in the maternal circulation for the prenatal detection of chromosome abnormalities and the evidence in support of each. A number of areas of ongoing controversy are addressed, including the timing of maternal blood sampling, the need for genetic counseling, and the use of confirmatory invasive testing. Future applications for this technology are also reviewed.
Hsu, Chung-Jen; Jones, Elizabeth G
2017-02-01
This paper performs sensitivity analyses of stopping distance for connected vehicles (CVs) at active highway-rail grade crossings (HRGCs). Stopping distance is the major safety factor at active HRGCs. A sensitivity analysis is performed for each variable in the function of stopping distance. The formulation of stopping distance treats each variable as a probability density function for implementing Monte Carlo simulations. The result of the sensitivity analysis shows that the initial speed is the most sensitive factor to stopping distances of CVs and non-CVs. The safety of CVs can be further improved by the early provision of onboard train information and warnings to reduce the initial speeds. Copyright © 2016 Elsevier Ltd. All rights reserved.
Environmental Considerations: Home and School Comparison of Spanish-English Speakers' Vocalizations
ERIC Educational Resources Information Center
Jackson, Carla W.; Callender, Maya F.
2014-01-01
This study examined differences in the quantity of child vocalizations (CVs) between preschool and home environments using the Language Environmental Analysis (LENA). The sample included monolingual English-speaking children (n = 27) and Spanish-English speaking dual language learners (n = 30). A two-way mixed effects analysis of variance with one…
Monreal, M; De Ancos, B; Cano, M P
1999-01-01
In this work a study of critical storage temperatures on pigment degradation of green beans (Phaseolus vulgaris, cvs. Perona and Boby) was conducted. In this way, green beans kept better quality at 4 degrees C than either 8 or 12 degrees C, maintaining a bright green color and good texture. Nevertheless, temperatures of 4 degrees C induced chilling injury (CI) after eight days of storage, which became evident when the pods were transferred to 20 degrees C. Cold storage temperatures, 12, 8, and 4 degrees C, produced different changes on the green beans chlorophyll profile. Green beans of both cultivars, Perona and Boby, stored at 4 and 12 degrees C showed a continuous degradation of chlorophyll pigments during storage, while samples stored at 8 degrees C showed an increase of chlorophyll content at the first 15 days. Carotenoid pigments also suffered different changes during cold storage. Perona was the green beans cultivar which maintained the higher level of lutein, mainly when samples were stored at the most suitable temperature (8 degrees C).
Predictions of a population of cataclysmic variables in globular clusters
NASA Technical Reports Server (NTRS)
Di Stefano, R.; Rappaport, S.
1994-01-01
We have studied the number of cataclysmic variables (CVs) that should be active in globular clusters during the present epoch as a result of binary formation via two-body tidal capture. We predict the orbital period and luminosity distributions of CVs in globular clusters. The results arebased on Monte Carlo simulations combined with evolution calculations appropriate to each system formed during the lifetime of two specific globular clusters, omega Cen and 47 Tuc. From our study of these two clusters, which represent the range of core densities and states of mass segregation that are likely to be interesting, we extrapolate our results to the Galactic globlular cluster system. Although there is at present little direct observational evidence of CVs in globular clusters, we find that there should be a large number of active systems. We predict that there should be more than approximately 100 CVs in both 47 Tuc and omega Cen and several thousand in the Galactic globular cluster system. These numbers are based on two-body processes alone and represent a lower bound on the number of systems that may have been formed as a result of stellar interaction within globular clusters. The relation between these calculations and the paucity of optically detected CVs in globular clusters is discussed. Should future observations fail to find convincing evidence of a substantial population of cluster CVs, then the two-body tidal capture scenario is likely to be seriously constrained. Of the CVs we espect in 47 Tuc and omega Cen, approximately 45 and 20, respectively, should have accretion luminosities above 10(exp 33) ergs/s. If one utilizes a relation for converting accretion luminosity to hard X-ray luminosity that is based on observations of Galactic plane CVs, even these sources will not exhibit X-ray luminosities above 10(exp 33) ergs/s. While we cannot account directly for the most luminous subset of the low-luminosity globular cluster X-ray sources without assuming an evolutionary pattern that is different from that of the majority of CVs in the disk, we are able to account for all of the observed lower luminosity subset of these sources, many of which have been recently discovered through ROSAT observations. In order for our predicted integrated cluster X-ray luminosities to be consistent with observational upper limits, the relation between accretion and X-ray luminosities should be something like that inferred from the Galactic plane population of CVs. Our calculations predict a large number of systems with L(sub acc) is less than 10(exp 32) ergs/s. Although our calculations imply that globular clusters should have an enhancement of CVs relative to the number thought to be present in the Galactic disk, this enhancement is at most roughly an order of magnitude, not comparable to the factor of approximately 100 for low-mass X-ray binaries (LMXBs).
NASA Astrophysics Data System (ADS)
Salinas, P.; Pavlidis, D.; Xie, Z.; Osman, H.; Pain, C. C.; Jackson, M. D.
2018-01-01
We present a new, high-order, control-volume-finite-element (CVFE) method for multiphase porous media flow with discontinuous 1st-order representation for pressure and discontinuous 2nd-order representation for velocity. The method has been implemented using unstructured tetrahedral meshes to discretize space. The method locally and globally conserves mass. However, unlike conventional CVFE formulations, the method presented here does not require the use of control volumes (CVs) that span the boundaries between domains with differing material properties. We demonstrate that the approach accurately preserves discontinuous saturation changes caused by permeability variations across such boundaries, allowing efficient simulation of flow in highly heterogeneous models. Moreover, accurate solutions are obtained at significantly lower computational cost than using conventional CVFE methods. We resolve a long-standing problem associated with the use of classical CVFE methods to model flow in highly heterogeneous porous media.
Galdino, Greg M; Gotway, Michael
2005-02-01
The curriculum vitae (CV) has been the traditional method for radiologists to illustrate their accomplishments in the field of medicine. Despite its presence in medicine as a standard, widely accepted means to describe one's professional career and its use for decades as an accomplice to most applications and interviews, there is relatively little written in the medical literature regarding the CV. Misrepresentation on medical students', residents', and fellows' applications has been reported. Using digital technology, CVs have the potential to be much more than printed words on paper and offers a solution to misrepresentation. Digital CVs may incorporate full-length articles, graphics, presentations, clinical images, and video. Common formats for digital CVs include CD-ROMs or DVD-ROMs containing articles (in Adobe Portable Document Format) and presentations (in Microsoft PowerPoint format) accompanying printed CVs, word processing documents with hyperlinks to articles and presentations either locally (on CD-ROMs or DVD-ROMs) or remotely (via the Internet), or hypertext markup language documents. Digital CVs afford the ability to provide more information that is readily accessible to those receiving and reviewing them. Articles, presentations, videos, images, and Internet links can be illustrated using standard file formats commonly available to all radiologists. They can be easily updated and distributed on an inexpensive media, such as a CD-ROM or DVD-ROM. With the availability of electronic articles, presentations, and information via the Internet, traditional paper CVs may soon be superseded by their electronic successors.
The reliability of a simplified water displacement instrument: a method for measuring arm volume.
Sagen, Ase; Kåresen, Rolf; Risberg, May Arna
2005-01-01
To present a new water displacement measurement, the Simplified Water Displacement Instrument (SWDI), and to evaluate its intra- and intertester reliability. Reliability design. Hospital setting. Fifty-six healthy people were studied. Intratester reliability was evaluated once a week for 4 weeks in 20 women and 10 men. Intertester reliability was assessed by 2 physical therapists in 26 people. Not applicable. Coefficients of variation (CVs) and intraclass correlation coefficients (ICCs). The intratester reliability showed a CV range of 2.2% to 2.6% and an ICC range of .98 to .99. The intertester reliability showed a CV of 1.3% and an ICC of .99. There was a significant increase in arm volume in men compared with women. There were no significant differences in changes in volume over the 4 weeks. There was a significant greater right arm volume (3.3%) among the right-handed subjects (P<.001). Both intra- and intertester reliability were satisfactory for the SWDI.
Influence of Caloric Vestibular Stimulation on Body Experience in Healthy Humans
Schönherr, Andreas; May, Christian Albrecht
2016-01-01
The vestibular system has more connections with and influence on higher cortical centers than previously thought. These interactions with higher cortical centers and the phenomena that they elicit require a structural intact cerebral cortex. To date, little is known about the role and influence of the vestibular system on one’s body experience. In this study we show that caloric vestibular stimulation (CVS) in healthy participants has an effect on the perceptive component of one’s body experience. After CVS all participants showed a statistically significant difference of thigh width estimation. In contrast to previous studies, which demonstrated an influence of CVS on higher cortical centers with an intact cerebral cortex both the cognitive and affective component of body experience were not effected by the CVS. Our results demonstrate the influence of the vestibular system on body perception and emphasize its role in modulating different perceptive-qualities which contributes to our body experience. We found that CVS has a limited influence on one’s conscious state, thought process and higher cortical functions. PMID:27013995
Floridia, M; Masuelli, G; Meloni, A; Cetin, I; Tamburrini, E; Cavaliere, A F; Dalzero, S; Sansone, M; Alberico, S; Guerra, B; Spinillo, A; Chiadò Fiorio Tin, M; Ravizza, M
2017-07-01
To assess in pregnant women with HIV the rates of amniocentesis and chorionic villus sampling (CVS), and the outcomes associated with such procedures. Observational study. Data from the Italian National Program on Surveillance on Antiretroviral Treatment in Pregnancy were used. University and hospital clinics. Pregnant women with HIV. Temporal trends were analysed by analysis of variance and by the Chi-square test for trend. Quantitative variables were compared by Student's t-test and categorical data by the Chi-square test, with odds ratios and 95% confidence intervals calculated. Rate of invasive testing, intrauterine death, HIV transmission. Between 2001 and 2015, among 2065 pregnancies in women with HIV, 113 (5.5%) had invasive tests performed. The procedures were conducted under antiretroviral treatment in 99 cases (87.6%), with a significant increase over time in the proportion of tests performed under highly active antiretroviral therapy (HAART) (100% in 2011-2015). Three intrauterine deaths were observed (2.6%), and 14 pregnancies were terminated because of fetal anomalies. Among 96 live newborns, eight had no information available on HIV status. Among the remaining 88 cases with either amniocentesis (n = 75), CVS (n = 12), or both (n = 1), two HIV transmissions occurred (2.3%). No HIV transmission occurred among the women who were on HAART at the time of invasive testing, and none after 2005. The findings reinforce the assumption that invasive prenatal testing does not increase the risk of HIV vertical transmission among pregnant women under suppressive antiretroviral treatment. No HIV transmission occurred among women who underwent amniocentesis or CVS under effective anti-HIV regimens. © 2016 Royal College of Obstetricians and Gynaecologists.
Advanced composite vertical stabilizer for DC-10 transport aircraft
NASA Technical Reports Server (NTRS)
Stephens, C. O.
1979-01-01
Structural design, tooling, fabrication, and test activities are reported for a program to develop an advanced composite vertical stabilizer (CVS) for the DC 10 Commercial Transport Aircraft. Structural design details are described and the status of structural and weight analyses are reported. A structural weight reduction of 21.7% is currently predicted. Test results are discussed for sine wave stiffened shear webs containing representative of the CVS spar webs and for lightning current transfer and tests on a panel representative of the CVS skins.
Continuous-Variable Instantaneous Quantum Computing is Hard to Sample.
Douce, T; Markham, D; Kashefi, E; Diamanti, E; Coudreau, T; Milman, P; van Loock, P; Ferrini, G
2017-02-17
Instantaneous quantum computing is a subuniversal quantum complexity class, whose circuits have proven to be hard to simulate classically in the discrete-variable realm. We extend this proof to the continuous-variable (CV) domain by using squeezed states and homodyne detection, and by exploring the properties of postselected circuits. In order to treat postselection in CVs, we consider finitely resolved homodyne detectors, corresponding to a realistic scheme based on discrete probability distributions of the measurement outcomes. The unavoidable errors stemming from the use of finitely squeezed states are suppressed through a qubit-into-oscillator Gottesman-Kitaev-Preskill encoding of quantum information, which was previously shown to enable fault-tolerant CV quantum computation. Finally, we show that, in order to render postselected computational classes in CVs meaningful, a logarithmic scaling of the squeezing parameter with the circuit size is necessary, translating into a polynomial scaling of the input energy.
Six consecutive false positive cases from cell-free fetal DNA testing in a single referring centre
Dugo, Nella; Padula, Francesco; Mobili, Luisa; Brizzi, Cristiana; D’Emidio, Laura; Cignini, Pietro; Mesoraca, Alvaro; Bizzoco, Domenico; Cima, Antonella; Giorlandino, Claudio
2014-01-01
Introduction recent studies have proposed the introduction of cell-free fetal DNA testing (NIPT-Non Invasive Prenatal Testing) in routine clinical practice emphasizing its high sensibility and specificity. In any case, false positive and false negative findings may result from placental mosaicism, because cell-free fetal DNA originates mainly from placenta. Case we report six cases of women who underwent chorionic villus sampling (CVS) or amniocentesis to confirm the results from NIPT: two Turner syndromes, two Triple X, one Patau syndrome, one Edward syndrome. Results using classic cytogenetic analysis and, also, Array - Comparative Genomic Hybridization (Array CGH) the karyotype of all 5 fetuses was found to be normal. Conclusion results from NIPT must always be confirmed by invasive prenatal diagnosis. It is mandatory to inform the patient that the CVS and amniocentesis still represent the only form of prenatal diagnostic test available. PMID:25332757
Dick, P T
1996-02-15
To make recommendations to physicians providing prenatal care on (1) whether prenatal screening for and diagnosis of Down syndrome (DS) is advisable and (2) alternative screening and diagnosis manoeuvres. "Triple-marker" screening of maternal serum levels of alpha-fetoprotein, human chorionic gonadotropin and unconjugated estriol; fetal ultrasonographic examination; amniocentesis; and chorionic villus sampling (CVS). Accuracy of detection of DS in fetuses, and risks to the mother, including psychologic distress, and to the fetus from the screening and diagnostic interventions. A MEDLINE search for relevant articles published from Jan. 1, 1966, to Mar. 31, 1994, with the use of MeSH terms "Down syndrome," "prenatal diagnosis," "screening," "prevention," "amniocentesis," "chorionic villus sampling," "ultrasonography," "anxiety," "depression" and "psychological stress" and a manual search of bibliographies, recent issues of key journals and Current Contents. The evidence-based methods and values of the Canadian Task Force on the Periodic Health Examination were used. A high value was placed on providing pregnant women with the opportunity to determine whether they are carrying a fetus with DS and to make choices concerning the termination of the pregnancy. The economic issues involved are complex and were not considered. Triple-marker screening identifies an estimated 58% of fetuses with DS, but it has an estimated rate of true-positive results of 0.1% and of false-positive results of 3.7% (given a risk cut-off of one chance in 190 of DS). These rates vary with maternal age and the risk cut-off chosen. Women with a known risk of having a fetus with DS (e.g., those who have had a previous child with DS) may benefit from a reduction in anxiety after confirmation that their fetus does not have DS. Screening allows women at low risk of having a child with DS to detect fetuses with the syndrome, but may cause psychologic distress if there is a false-positive screening test result. Up to 20% of women with positive results of screening tests may decline to undergo a subsequent amniocentesis. Amniocentesis and CVS are very accurate in diagnosing DS in fetuses and have a very low rate of serious complications for the mother. Amniocentesis is associated with a 1.7% rate of fetal loss when it is performed after 16 weeks' gestation, whereas the rate among controls is 0.7% (for a difference of 1%, 95% confidence interval 0.3% to 1.5%). CVS entails a greater risk of fetal loss than amniocentesis (odds ratio 1.32, 95% confidence interval 1.11 to 1.57). There is little evidence from controlled trials of significant associations between amniocentesis or CVS and neonatal morbidity or malformations; however, samples have been too small to show differences in rare outcomes. Results from some case-control studies suggest that CVS increases the risk of transverse limb deficiency. Costs were not considered because they are beyond the scope of this review. There is fair evidence to offer triple-marker screening through a comprehensive program to pregnant women under 35 years of age (grade B recommendation). Women given detailed information about serum-marker screening show more satisfaction with the screening than those not given this information. There is fair evidence to offer amniocentesis or CVS to pregnant women 35 years of age and older and to women with a history of a fetus with DS or of a chromosome 21 anomaly (grade B recommendation). Information on the limitations and advantages of each procedure should be offered. Triple-marker screening may be offered as an alternative to CVS or amniocentesis to pregnant women over 35. Recommendations concerning prenatal diagnosis are similar to those of the US Preventive Services Task Force, the Society of Obstetricians and Gynaecologists of Canada, the Canadian College of Medical Geneticists and the Cochrane Pregnancy and Childbirth Group. No previous specific recommendations concerning triple-maker screening exist. These guidelines were developed and endorsed by the Canadian Task Force on the Periodic Health Examination, which is funded by Health Canada and the National Health Research and Development Program.
Probing the nature of cataclysmic variables via photometric studies on multiple timescales
NASA Astrophysics Data System (ADS)
Armstrong, Eve
I examine the structure and evolution of hydrogen- and helium-rich cataclysmic variables (CVs), via their periodic variability captured by long-term time series photometry. Studies to be discussed address one of two sets of question. One set pertains to helium CVs, which are poorly understood relative to their hydrogen-rich counterparts: What is the long-term evolution - in terms of orbital period (Porb) - of He CVs, and what does this imply about the nature of their secondaries? Two methods of investigation are employed: i) using systems with positive superhump and orbital period detections (Chapter 3) in order to chart the distribution of Porb versus time for He CVs (Chapter 4); ii) direct pulse timing of Porb in one system, via an 18-year baseline of photometry (Chapter 5). Results of the first study indicate that helium CVs are evolving toward longer Porb and have secondaries that are well described as degenerate objects. The pulse timing of one object (and the same measurement in two other He CVs) shows no evidence for Porb lengthening, and is consistent with Porb shortening driven by angular momentum loss via gravitational wave radiation. Technically, the two results are not inconsistent, as AM CVn is the only point on the distribution with a Porb timing. The apparent contradiction, however, illuminates our poor understanding of this class of CV: their routes to birth and the range of paths that a star can take following core hydrogen burning. The second set of studies pertains to signals associated with the accretion disc: Can a CV's accretion disc tilt with respect to the orbital plane? And what is the geometry and behavior of matter at various annuli in a tilted disc? To this end, I examine orbital sideband signals in AM CVn (Chapter 6) and simultaneous orbital sidebands and superorbital signals in two hydrogen CVs (Chapter 7). I also tabulate, from the literature, ten additional CVs with reliable detections of these signals (Chapter 7). All results indicate that the mechanism of tilt is at work in these objects.
Li, Belinda S Y; Wang, Hao; Gonen, Oded
2003-10-01
In localized brain proton MR spectroscopy ((1)H-MRS), metabolites' levels are often expressed as ratios, rather than as absolute concentrations. Frequently, their denominator is the creatine [Cr], which level is explicitly assumed to be stable in normal as well as in many pathologic states. The rationale is that ratios self-correct for imager and localization method differences, gain instabilities, regional susceptibility variations and partial volume effects. The implicit assumption is that these benefits are worth their cost(w)-(w) propagation of the individual variation of each of the ratio's components. To test this hypothesis, absolute levels of N-acetylaspartate [NAA], choline [Cho] and [Cr] were quantified in various regions of the brains of 8 volunteers, using 3-dimensional (3D) (1)H-MRS at 1.5 T. The results show that in over 50% of approximately 2000 voxels examined, [NAA]/[Cr] and [Cho]/[Cr] exhibited higher coefficients of variations (CV) than [NAA] and [Cho] individually. Furthermore, in approximately 33% of these voxels, the ratios' CVs exceeded even the combined constituents' CVs. Consequently, basing metabolite quantification on ratios and assuming stable [Cr] introduces more variability into (1)H-MRS than it prevents. Therefore, its cost exceeds the benefit.
40 CFR 86.107-96 - Sampling and analytical systems; evaporative emissions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... temperature sensors. The PDP-CVS shall conform to the following requirements: (A) The gas mixture temperature... sealed, the enclosure shall be gas tight in accordance with § 86.117-96. Interior surfaces must be... shall be gas tight in accordance with § 86.117-96. The enclosure may be equipped with a personnel door...
40 CFR 86.107-96 - Sampling and analytical systems; evaporative emissions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... temperature sensors. The PDP-CVS shall conform to the following requirements: (A) The gas mixture temperature... sealed, the enclosure shall be gas tight in accordance with § 86.117-96. Interior surfaces must be... shall be gas tight in accordance with § 86.117-96. The enclosure may be equipped with a personnel door...
40 CFR 89.421 - Exhaust gas analytical system; CVS bag sample.
Code of Federal Regulations, 2012 CFR
2012-07-01
... essentially free of CO2 and water vapor interference, the use of the conditioning column may be deleted. (See... and water vapor interference if its response to a mixture of 3 percent CO2 in N2, which has been bubbled through water at room temperature, produces an equivalent CO response, as measured on the most...
40 CFR 86.1311-94 - Exhaust gas analytical system; CVS bag sample.
Code of Federal Regulations, 2011 CFR
2011-07-01
... desiccating silica gel to remove water vapor, and containing ascarite to remove carbon dioxide from the CO analysis stream. (i) If CO instruments are used which are essentially free of CO2 and water vapor... instrument will be considered to be essentially free of CO2 and water vapor interference if its response to a...
40 CFR 89.421 - Exhaust gas analytical system; CVS bag sample.
Code of Federal Regulations, 2011 CFR
2011-07-01
... essentially free of CO2 and water vapor interference, the use of the conditioning column may be deleted. (See... and water vapor interference if its response to a mixture of 3 percent CO2 in N2, which has been bubbled through water at room temperature, produces an equivalent CO response, as measured on the most...
40 CFR 89.421 - Exhaust gas analytical system; CVS bag sample.
Code of Federal Regulations, 2010 CFR
2010-07-01
... essentially free of CO2 and water vapor interference, the use of the conditioning column may be deleted. (See... and water vapor interference if its response to a mixture of 3 percent CO2 in N2, which has been bubbled through water at room temperature, produces an equivalent CO response, as measured on the most...
40 CFR 86.1311-94 - Exhaust gas analytical system; CVS bag sample.
Code of Federal Regulations, 2012 CFR
2012-07-01
... desiccating silica gel to remove water vapor, and containing ascarite to remove carbon dioxide from the CO analysis stream. (i) If CO instruments are used which are essentially free of CO2 and water vapor... instrument will be considered to be essentially free of CO2 and water vapor interference if its response to a...
40 CFR 89.421 - Exhaust gas analytical system; CVS bag sample.
Code of Federal Regulations, 2013 CFR
2013-07-01
... essentially free of CO2 and water vapor interference, the use of the conditioning column may be deleted. (See... and water vapor interference if its response to a mixture of 3 percent CO2 in N2, which has been bubbled through water at room temperature, produces an equivalent CO response, as measured on the most...
40 CFR 89.421 - Exhaust gas analytical system; CVS bag sample.
Code of Federal Regulations, 2014 CFR
2014-07-01
... essentially free of CO2 and water vapor interference, the use of the conditioning column may be deleted. (See... and water vapor interference if its response to a mixture of 3 percent CO2 in N2, which has been bubbled through water at room temperature, produces an equivalent CO response, as measured on the most...
40 CFR 86.1311-94 - Exhaust gas analytical system; CVS bag sample.
Code of Federal Regulations, 2010 CFR
2010-07-01
... desiccating silica gel to remove water vapor, and containing ascarite to remove carbon dioxide from the CO analysis stream. (i) If CO instruments are used which are essentially free of CO2 and water vapor... instrument will be considered to be essentially free of CO2 and water vapor interference if its response to a...
40 CFR 86.1311-94 - Exhaust gas analytical system; CVS bag sample.
Code of Federal Regulations, 2013 CFR
2013-07-01
... desiccating silica gel to remove water vapor, and containing ascarite to remove carbon dioxide from the CO analysis stream. (i) If CO instruments are used which are essentially free of CO2 and water vapor... instrument will be considered to be essentially free of CO2 and water vapor interference if its response to a...
Polyakova, Maryna; Schlögl, Haiko; Sacher, Julia; Schmidt-Kassow, Maren; Kaiser, Jochen; Stumvoll, Michael; Kratzsch, Jürgen; Schroeter, Matthias L
2017-06-03
Brain-derived neurotrophic factor (BDNF), an important neural growth factor, has gained growing interest in neuroscience, but many influencing physiological and analytical aspects still remain unclear. In this study we assessed the impact of storage time at room temperature, repeated freeze/thaw cycles, and storage at -80 °C up to 6 months on serum and ethylenediaminetetraacetic acid (EDTA)-plasma BDNF. Furthermore, we assessed correlations of serum and plasma BDNF concentrations in two independent sets of samples. Coefficients of variations (CVs) for serum BDNF concentrations were significantly lower than CVs of plasma concentrations ( n = 245, p = 0.006). Mean serum and plasma concentrations at all analyzed time points remained within the acceptable change limit of the inter-assay precision as declared by the manufacturer. Serum and plasma BDNF concentrations correlated positively in both sets of samples and at all analyzed time points of the stability assessment ( r = 0.455 to r s = 0.596; p < 0.004). In summary, when considering the acceptable change limit, BDNF was stable in serum and in EDTA-plasma up to 6 months. Due to a higher reliability, we suggest favoring serum over EDTA-plasma for future experiments assessing peripheral BDNF concentrations.
Jeong, Sang-Chul; Yang, Byung-Keun; Kim, Guk-Nam; Jeong, Hun; Wilson, Michael A; Cho, Yip; Rao, K Sundar; Song, Chi-Hyun
2006-01-01
The macrophage-stimulating effect of polysaccharides extracted from Coriolus versicolor (Turkey Tail mushroom) was investigated, and their effectiveness was compared with that of lipopolysaccharide (LPS). The purified polysaccharide (CV-S2-Fr.I) of C. versicolor obtained by Sepharose CL-6B gel chromatography stimulated macrophage lysosomal enzyme activity by 250% at a concentration of 100 microg/mL, which was higher than that of LPS at the same concentration. When CV-S2-Fr.I was used in combination with interferon-gamma, there was a marked cooperative induction of nitric oxide production. However, CV-S2-Fr.I had no effect on nitric oxide production by itself. The proportion of C3-positive macrophages in the CV-S2-Fr.I group increased by 7.2-fold compared with the control group.
Bestetti, Reinaldo Bulgarelli; Restini, Carolina Baraldi A; Couto, Lucélio B
2014-12-01
Our knowledge regarding the anatomophysiology of the cardiovascular system (CVS) has progressed since the fourth millennium BC. In Egypt (3500 BC), it was believed that a set of channels are interconnected to the heart, transporting air, urine, air, blood, and the soul. One thousand years later, the heart was established as the center of the CVS by the Hippocratic Corpus in the medical school of Kos, and some of the CVS anatomical characteristics were defined. The CVS was known to transport blood via the right ventricle through veins and the pneuma via the left ventricle through arteries. Two hundred years later, in Alexandria, following the development of human anatomical dissection, Herophilus discovered that arteries were 6 times thicker than veins, and Erasistratus described the semilunar valves, emphasizing that arteries were filled with blood when ventricles were empty. Further, 200 years later, Galen demonstrated that arteries contained blood and not air. With the decline of the Roman Empire, Greco-Roman medical knowledge about the CVS was preserved in Persia, and later in Islam where, Ibn Nafis inaccurately described pulmonary circulation. The resurgence of dissection of the human body in Europe in the 14th century was associated with the revival of the knowledge pertaining to the CVS. The main findings were the description of pulmonary circulation by Servetus, the anatomical discoveries of Vesalius, the demonstration of pulmonary circulation by Colombo, and the discovery of valves in veins by Fabricius. Following these developments, Harvey described blood circulation.
Bestetti, Reinaldo Bulgarelli; Restini, Carolina Baraldi A; Couto, Lucélio B
2014-10-10
Our knowledge regarding the anatomophysiology of the cardiovascular system (CVS) has progressed since the fourth millennium BC. In Egypt (3500 BC), it was believed that a set of channels are interconnected to the heart, transporting air, urine, air, blood, and the soul. One thousand years later, the heart was established as the center of the CVS by the Hippocratic Corpus in the medical school of Kos, and some of the CVS anatomical characteristics were defined. The CVS was known to transport blood via the right ventricle through veins and the pneuma via the left ventricle through arteries. Two hundred years later, in Alexandria, following the development of human anatomical dissection, Herophilus discovered that arteries were 6 times thicker than veins, and Erasistratus described the semilunar valves, emphasizing that arteries were filled with blood when ventricles were empty. Further, 200 years later, Galen demonstrated that arteries contained blood and not air. With the decline of the Roman Empire, Greco-Roman medical knowledge about the CVS was preserved in Persia, and later in Islam where, Ibn Nafis inaccurately described pulmonary circulation. The resurgence of dissection of the human body in Europe in the 14th century was associated with the revival of the knowledge pertaining to the CVS. The main findings were the description of pulmonary circulation by Servetus, the anatomical discoveries of Vesalius, the demonstration of pulmonary circulation by Colombo, and the discovery of valves in veins by Fabricius. Following these developments, Harvey described blood circulation.
Bestetti, Reinaldo Bulgarelli; Restini, Carolina Baraldi A.; Couto, Lucélio B.
2014-01-01
Our knowledge regarding the anatomophysiology of the cardiovascular system (CVS) has progressed since the fourth millennium BC. In Egypt (3500 BC), it was believed that a set of channels are interconnected to the heart, transporting air, urine, air, blood, and the soul. One thousand years later, the heart was established as the center of the CVS by the Hippocratic Corpus in the medical school of Kos, and some of the CVS anatomical characteristics were defined. The CVS was known to transport blood via the right ventricle through veins and the pneuma via the left ventricle through arteries. Two hundred years later, in Alexandria, following the development of human anatomical dissection, Herophilus discovered that arteries were 6 times thicker than veins, and Erasistratus described the semilunar valves, emphasizing that arteries were filled with blood when ventricles were empty. Further, 200 years later, Galen demonstrated that arteries contained blood and not air. With the decline of the Roman Empire, Greco-Roman medical knowledge about the CVS was preserved in Persia, and later in Islam where, Ibn Nafis inaccurately described pulmonary circulation. The resurgence of dissection of the human body in Europe in the 14th century was associated with the revival of the knowledge pertaining to the CVS. The main findings were the description of pulmonary circulation by Servetus, the anatomical discoveries of Vesalius, the demonstration of pulmonary circulation by Colombo, and the discovery of valves in veins by Fabricius. Following these developments, Harvey described blood circulation. PMID:25590934
Mitochondrial disorder caused Charles Darwin's cyclic vomiting syndrome.
Finsterer, Josef; Hayman, John
2014-01-08
Charles Darwin (CD), "father of modern biology," suffered from multisystem illness from early adulthood. The most disabling manifestation was cyclic vomiting syndrome (CVS). This study aims at finding the possible cause of CVS in CD. A literature search using the PubMed database was carried out, and CD's complaints, as reported in his personal writings and those of his relatives, friends, colleagues, biographers, were compared with various manifestations of mitochondrial disorders (MIDs), known to cause CVS, described in the literature. Organ tissues involved in CD's disease were brain, nerves, muscles, vestibular apparatus, heart, gut, and skin. Cerebral manifestations included episodic headache, visual disturbance, episodic memory loss, periodic paralysis, hysterical crying, panic attacks, and episodes of depression. Manifestations of polyneuropathy included numbness, paresthesias, increased sweating, temperature sensitivity, and arterial hypotension. Muscular manifestations included periods of exhaustion, easy fatigability, myalgia, and muscle twitching. Cardiac manifestations included episodes of palpitations and chest pain. Gastrointestinal manifestations were CVS, dental problems, abnormal seasickness, eructation, belching, and flatulence. Dermatological manifestations included painful lips, dermatitis, eczema, and facial edema. Treatments with beneficial effects to his complaints were rest, relaxation, heat, and hydrotherapy. CVS in CD was most likely due to a multisystem, nonsyndromic MID. This diagnosis is based upon the multisystem nature of his disease, the fact that CVS is most frequently the manifestation of a MID, the family history, the variable phenotypic expression between affected family members, the fact that symptoms were triggered by stress, and that only few symptoms could not be explained by a MID.
Chronic varied stress modulates experimental autoimmune encephalomyelitis in Wistar rats.
Correa, S G; Rodriguez-Galán, M C; Rivero, V E; Riera, C M
1998-06-01
Stress disturbs homeostasis by altering the equilibrium of various hormones which have a significant impact on immune responses. Few studies have examined the influence of stressors on autoimmune disease in animal models. In our work, we studied the effects of long-term exposure (14 days) to chronic varied stress (CVS) in a model of experimental autoimmune encephalomyelitis (EAE) in Wistar rats. We studied whether the exposure to CVS before or after the immune challenge would correlate with differences in the clinical course of the disease. We also examined whether the CVS would modulate the magnitude of the cellular or the humoral immune response. We observed opposite effects on the clinical signs in animals stressed before or after the immune challenge. The clinical signs of the disease were attenuated in animals stressed before but not after the immune challenge. Relationships were found in the modulation of the clinical severity related to the time of exposure to the CVS, the histological alterations and the proliferative results. Stressed animals with milder clinical signs presented an exacerbated humoral response against myelin antigens while stressed animals with more severe clinical symptoms exhibited a significantly diminished one. Besides, we detected the presence of specific IgG1 associated with the exposure to CVS before the induction of EAE. Our results show that, depending on the timing of the exposure of Wistar rats to the CVS, the neuroendocrine disbalance favors a more pronounced humoral or cellular profile of the response.
On the origin of the iron fluorescent line emission from the Galactic Ridge
NASA Astrophysics Data System (ADS)
Eze, R. N. C.
2015-04-01
The Galactic Ridge X-ray Emission (GRXE) spectrum has strong iron emission lines at 6.4, 6.7, and 7.0 keV, each corresponding to the neutral (or low-ionized), He-like, and H-like iron ions. The 6.4 keV fluorescence line is due to irradiation of neutral (or low ionized) material (iron) by hard X-ray sources, indicating uniform presence of the cold matter in the Galactic plane. In order to resolve the origin of the cold fluorescent matter, we examined the contribution of the 6.4 keV line emission from white dwarf surfaces in the hard X-ray emitting symbiotic stars (hSSs) and magnetic cataclysmic variables (mCVs) to the GRXE. In our spectral analysis of 4 hSSs and 19 mCVs observed with Suzaku, we were able to resolve the three iron emission lines. We found that the equivalent-widths (EWs) of the 6.4 keV lines of hSSs are systematically higher than those of mCVs, such that the EWs of the merged hSSs and mCVs are 179-11+46 eV and 93-3+20 eV, respectively. The EW of hSSs compares favorably with the typical EWs of the 6.4 keV line in the GRXE of 90-300 eV depending on Galactic positions. Average 6.4 keV line luminosities of the hSSs and mCVs are 9.2 ×1039 and 1.6 ×1039 photons s-1, respectively, indicating that hSSs are intrinsically more efficient 6.4 keV line emitters than mCVs. We estimated required space densities of hSSs and mCVs to account for all the GRXE 6.4 keV line emission flux to be 2 ×10-7 pc-3 and 1 ×10-6 pc-3, respectively. We also estimated the actual 6.4 keV line contribution from the mCVs with a known space density, which is as much as 20% of the observed GRXE flux, and for the hSSs, for which only five hSSs are known, we noted that they could contribute a significant percentage to the observed GRXE flux since we believe there is still more hSSs yet to be discovered in the Galaxy. We therefore conclude that the GRXE 6.4 keV line flux could be significantly explained by hSSs and mCVs 6.4 keV line flux.
Migration of the Gaudi and LHCb software repositories from CVS to Subversion
NASA Astrophysics Data System (ADS)
Clemencic, M.; Degaudenzi, H.; LHCb Collaboration
2011-12-01
A common code repository is of primary importance in a distributed development environment such as large HEP experiments. CVS (Concurrent Versions System) has been used in the past years at CERN for the hosting of shared software repositories, among which were the repositories for the Gaudi Framework and the LHCb software projects. Many developers around the world produced alternative systems to share code and revisions among several developers, mainly to overcome the limitations in CVS, and CERN has recently started a new service for code hosting based on the version control system Subversion. The differences between CVS and Subversion and the way the code was organized in Gaudi and LHCb CVS repositories required careful study and planning of the migration. Special care was used to define the organization of the new Subversion repository. To avoid as much as possible disruption in the development cycle, the migration has been gradual with the help of tools developed explicitly to hide the differences between the two systems. The principles guiding the migration steps, the organization of the Subversion repository and the tools developed will be presented, as well as the problems encountered both from the librarian and the user points of view.
40 CFR 1065.340 - Diluted exhaust flow (CVS) calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
... initial CVS installation and whenever corrective action does not resolve a failure to meet the diluted... such as a subsonic venturi flow meter, a long-radius ASME/NIST flow nozzle, a smooth approach orifice...
40 CFR 1065.340 - Diluted exhaust flow (CVS) calibration.
Code of Federal Regulations, 2012 CFR
2012-07-01
... initial CVS installation and whenever corrective action does not resolve a failure to meet the diluted... such as a subsonic venturi flow meter, a long-radius ASME/NIST flow nozzle, a smooth approach orifice...
40 CFR 1065.340 - Diluted exhaust flow (CVS) calibration.
Code of Federal Regulations, 2014 CFR
2014-07-01
... initial CVS installation and whenever corrective action does not resolve a failure to meet the diluted... such as a subsonic venturi flow meter, a long-radius ASME/NIST flow nozzle, a smooth approach orifice...
Multidisciplinary perspectives on banana (Musa spp.) domestication
Perrier, Xavier; De Langhe, Edmond; Donohue, Mark; Lentfer, Carol; Vrydaghs, Luc; Bakry, Frédéric; Carreel, Françoise; Hippolyte, Isabelle; Horry, Jean-Pierre; Jenny, Christophe; Lebot, Vincent; Risterucci, Ange-Marie; Tomekpe, Kodjo; Doutrelepont, Hugues; Ball, Terry; Manwaring, Jason; de Maret, Pierre; Denham, Tim
2011-01-01
Original multidisciplinary research hereby clarifies the complex geodomestication pathways that generated the vast range of banana cultivars (cvs). Genetic analyses identify the wild ancestors of modern-day cvs and elucidate several key stages of domestication for different cv groups. Archaeology and linguistics shed light on the historical roles of people in the movement and cultivation of bananas from New Guinea to West Africa during the Holocene. The historical reconstruction of domestication processes is essential for breeding programs seeking to diversify and improve banana cvs for the future. PMID:21730145
Washington, Chad W; Derdeyn, Colin P; Dhar, Rajat; Arias, Eric J; Chicoine, Michael R; Cross, DeWitte T; Dacey, Ralph G; Han, Byung Hee; Moran, Christopher J; Rich, Keith M; Vellimana, Ananth K; Zipfel, Gregory J
2016-02-01
Studies show that phosphodiesterase-V (PDE-V) inhibition reduces cerebral vasospasm (CVS) and improves outcomes after experimental subarachnoid hemorrhage (SAH). This study was performed to investigate the safety and effect of sildenafil (an FDA-approved PDE-V inhibitor) on angiographic CVS in SAH patients. A2-phase, prospective, nonrandomized, human trial was implemented. Subarachnoid hemorrhage patients underwent angiography on Day 7 to assess for CVS. Those with CVS were given 10 mg of intravenous sildenafil in the first phase of the study and 30 mg in the second phase. In both, angiography was repeated 30 minutes after infusion. Safety was assessed by monitoring neurological examination findings and vital signs and for the development of adverse reactions. For angiographic assessment, in a blinded fashion, pre- and post-sildenafil images were graded as "improvement" or "no improvement" in CVS. Unblinded measurements were made between pre- and post-sildenafil angiograms. Twelve patients received sildenafil; 5 patients received 10 mg and 7 received 30 mg. There were no adverse reactions. There was no adverse effect on heart rate or intracranial pressure. Sildenafil resulted in a transient decline in mean arterial pressure, an average of 17% with a return to baseline in an average of 18 minutes. Eight patients (67%) were found to have a positive angiographic response to sildenafil, 3 (60%) in the low-dose group and 5 (71%) in the high-dose group. The largest degree of vessel dilation was an average of 0.8 mm (range 0-2.1 mm). This corresponded to an average percentage increase in vessel diameter of 62% (range 0%-200%). The results from this Phase I safety and proof-of-concept trial assessing the use of intravenous sildenafil in patients with CVS show that sildenafil is safe and well tolerated in the setting of SAH. Furthermore, the angiographic data suggest that sildenafil has a positive impact on human CVS.
Primary Stenting Is Not Necessary in Benign Central Venous Stenosis.
Rangel, Lynsey E; Lyden, Sean P; Clair, Daniel G
2018-01-01
The aim of this study is to evaluate central venous stenosis (CVS) etiologies and presentation within a vascular surgery practice. We evaluated endovascular treatment modalities and the patency rates of our interventions. Five-year retrospective review of endovascular intervention for CVS. Patient demographics, medical comorbidities, and variables were collected including etiology, indwelling device, previous upper extremity (UE) deep venous thrombosis, long-term UE indwelling device (defined as >30 days), malignancy status, hypercoagulable disorders, history of radiation or mediastinal fibrosis or masses, and anticoagulation and/or antiplatelet therapy. Follow-up variables included symptoms, imaging, and anticoagulation and/or antiplatelet utilization. Living patients without recent follow-up were contacted with a telephone survey regarding current symptoms. Patency was evaluated by imaging or clinically by recurrence of signs or symptoms through January 2016. A total of 61 patients underwent attempted endovascular CVS interventions from January 2007 to 2013. Forty-seven (83%) patients had successful interventions. There were 22 (36%) end-stage renal disease (ESRD) patients. The primary etiology in 79% of patients was benign CVS secondary to an indwelling device. Eighty-nine percent of the interventions were primary angioplasty (PTA). The overall primary patency rates at 6, 12, and 24 months were 49%, 34%, and 24%, respectively. Secondary patency rates at 6, 12, and 24 months were 97%, 93%, and 88%, respectively. There were no statistical differences in demographics or outcomes in patients treated successfully with PTA or those requiring stenting. There was no statistical difference in the patency rates between ESRD and non-ESRD patients. Previous interventions were not a predictor of loss of patency. Our study supported the rising trend of benign CVS predominantly secondary to indwelling devices. We demonstrated acceptable secondary patency with PTA alone. This study adds further support for a primary angioplasty strategy in treating benign CVS. The optimal endovascular treatment for benign CVS is still undefined. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sion, Edward M.; Sparks, Warren, E-mail: edward.sion@villanova.edu, E-mail: warrensparks@comcast.net
2014-11-20
The detection of heavy elements at suprasolar abundances in the atmospheres of some accreting white dwarfs in cataclysmic variables (CVs), coupled with the high temperatures needed to produce these elements, requires explosive thermonuclear burning. The central temperatures of any formerly more massive secondary stars in CVs undergoing hydrostatic CNO burning are far too low to produce these elements. Evidence is presented that at least some CVs contain donor secondaries that have been contaminated by white dwarf remnant burning during the common envelope phase and are transferring this material back to the white dwarf. This scenario does not exclude the channelmore » in which formerly more massive donor stars underwent CNO processing in systems with thermal timescale mass transfer. Implications for the progenitors of CVs are discussed and a new scenario for the white dwarf's accretion-nova-outburst is given.« less
Yang, Hong; Marwick, Thomas H; Fukuda, Nobuaki; Oe, Hiroki; Saito, Makoto; Thomas, James D; Negishi, Kazuaki
2015-06-01
Disagreement of strain measurements among different vendors has provided an obstacle to the clinical use of strain. A joint standardization task force between professional societies and industry was initiated to reduce intervendor variability of strain. Although feedback from this process has been used in software upgrades, little is known about the effects of efforts to improve conformity. The aim of this study was to assess whether intervendor agreement for global longitudinal strain (GLS) has improved after standardization initiatives. Eighty-two subjects (mean age, 52 ± 21 years; 55% men) prospectively underwent two sequential examinations using two most common ultrasound systems (Vivid E9 and iE33). GLS was calculated using proprietary software (EchoPAC-PC BT12 [E12] and BT13 [E13] vs QLAB version 8.0 [Q8], QLAB version 9.0 [Q9], and QLAB version 10.0 [Q10]). Agreements in GLS were evaluated with Bland-Altman plots. Coefficients of variation (CVs) were compared using the Friedman test and compared with CVs of left ventricular volumes and ejection fraction (LVEF). Median GLS using E12 was -19.2% (interquartile range [IQR], -15.2% to -23.2%), compared with -19.3% (IQR, -14.9% to -23.7%) for E13, -15.7% (IQR, -11.4% to -20%) for Q8, -19% (IQR, -15.7% to -22.3%) for Q9, and -18.7% (IQR, -15.7% to -21.7%) for Q10. The CVs of prestandardization GLS (12 ± 8% [E12/Q8] and 14 ± 8 [E13/Q8]) were significantly larger than that of LVEF (5 ± 5) (P < .001). Since standardization, the CVs of GLS have shown improvement (6 ± 4 [E12/Q9], 7 ± 4 [E12/Q10], 6 ± 4 [E13/Q9], and 7 ± 4 [E13/Q10]) and are similar to those of LVEF. Subsequent to the joint standardization task force, there has been improvement in between-vendor concordance in GLS between two leading ultrasound manufactures, the variability of which is now analogous to that of LVEF. The removal of concerns about measurement variability should allow wider use of GLS. Copyright © 2015 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
40 CFR 1065.340 - Diluted exhaust flow (CVS) calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
...-open position. (6) Operate the PDP for at least 3 min to stabilize the system. Continue operating the PDP and record the mean values of at least 30 seconds of sampled data of each of the following... the PDP, p in. (8) Repeat the steps in paragraphs (e)(6) and (7) of this section to record data at a...
40 CFR 91.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2013 CFR
2013-07-01
... and water vapor interference, the use of the conditioning column may be deleted. (See §§ 91.317 and 91.320.) (3) A CO instrument will be considered to be essentially free of CO2 and water vapor interference if its response to a mixture of three percent CO2 in N2, which has been bubbled through water at...
40 CFR 91.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2011 CFR
2011-07-01
... and water vapor interference, the use of the conditioning column may be deleted. (See §§ 91.317 and 91.320.) (3) A CO instrument will be considered to be essentially free of CO2 and water vapor interference if its response to a mixture of three percent CO2 in N2, which has been bubbled through water at...
40 CFR 91.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2012 CFR
2012-07-01
... and water vapor interference, the use of the conditioning column may be deleted. (See §§ 91.317 and 91.320.) (3) A CO instrument will be considered to be essentially free of CO2 and water vapor interference if its response to a mixture of three percent CO2 in N2, which has been bubbled through water at...
40 CFR 91.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2014 CFR
2014-07-01
... and water vapor interference, the use of the conditioning column may be deleted. (See §§ 91.317 and 91.320.) (3) A CO instrument will be considered to be essentially free of CO2 and water vapor interference if its response to a mixture of three percent CO2 in N2, which has been bubbled through water at...
40 CFR 91.423 - Exhaust gas analytical system; CVS grab sample.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and water vapor interference, the use of the conditioning column may be deleted. (See §§ 91.317 and 91.320.) (3) A CO instrument will be considered to be essentially free of CO2 and water vapor interference if its response to a mixture of three percent CO2 in N2, which has been bubbled through water at...
40 CFR 1065.341 - CVS and batch sampler verification (propane check).
Code of Federal Regulations, 2010 CFR
2010-07-01
... contamination. Otherwise, zero, span, and verify contamination of the HC sampling system, as follows: (1) Select... flow rates. (2) Zero the HC analyzer using zero air introduced at the analyzer port. (3) Span the HC analyzer using C3H8 span gas introduced at the analyzer port. (4) Overflow zero air at the HC probe inlet...
40 CFR 1065.341 - CVS and batch sampler verification (propane check).
Code of Federal Regulations, 2011 CFR
2011-07-01
... contamination. Otherwise, zero, span, and verify contamination of the HC sampling system, as follows: (1) Select... flow rates. (2) Zero the HC analyzer using zero air introduced at the analyzer port. (3) Span the HC analyzer using C3H8 span gas introduced at the analyzer port. (4) Overflow zero air at the HC probe inlet...
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
This report compares the energy use, oil use and emissions of electric vehicles (EVs) with those of conventional, gasoline- powered vehicles (CVs) over the total life cycle of the vehicles. The various stages included in the vehicles` life cycles include vehicle manufacture, fuel production, and vehicle operation. Disposal is not included. An inventory of the air emissions associated with each stage of the life cycle is estimated. Water pollutants and solid wastes are reported for individual processes, but no comprehensive inventory is developed. Volume II contains additional details on the vehicle, utility, and materials analyses and discusses several details ofmore » the methodology.« less
Deal, Shanley B; Alseidi, Adnan A
2017-12-01
Online videos are among the most common resources for case preparation. Using crowd sourcing, we evaluated the relationship between operative quality and viewing characteristics of online laparoscopic cholecystectomy videos. We edited 160 online videos of laparoscopic cholecystectomy to 60 seconds or less. Crowd workers (CW) rated videos using Global Objective Assessment of Laparoscopic Skills (GOALS), the critical view of safety (CVS) criteria, and assigned overall pass/fail ratings if CVS was achieved; linear mixed effects models derived average ratings. Views, likes, dislikes, subscribers, and country were recorded for subset analysis of YouTube videos. Spearman correlation coefficient (SCC) assessed correlation between performance measures. One video (0.06%) achieved a passing CVS score of ≥5; 23%, ≥4; 44%, ≥3; 79%, ≥2; and 100% ≥1. Pass/fail ratings correlated to CVS, SCC 0.95 (p < 0.001) and to GOALS, SCC 0.79 (p < 0.001). YouTube videos (n = 139) with higher views, likes, or subscribers did not correlate with better quality. The average CVS and GOALS scores were no different for videos with >20,000 views (22%) compared with those with <20,000 (78%). There is an incredibly low frequency of CVS and average GOALS technical performance in frequently used online surgical videos of LC. Favorable characteristics, such as number of views or likes, do not translate to higher quality. Copyright © 2017 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Electric vehicles in China: emissions and health impacts.
Ji, Shuguang; Cherry, Christopher R; J Bechle, Matthew; Wu, Ye; Marshall, Julian D
2012-02-21
E-bikes in China are the single largest adoption of alternative fuel vehicles in history, with more than 100 million e-bikes purchased in the past decade and vehicle ownership about 2× larger for e-bikes as for conventional cars; e-car sales, too, are rapidly growing. We compare emissions (CO(2), PM(2.5), NO(X), HC) and environmental health impacts (primary PM(2.5)) from the use of conventional vehicles (CVs) and electric vehicles (EVs) in 34 major cities in China. CO(2) emissions (g km(-1)) vary and are an order of magnitude greater for e-cars (135-274) and CVs (150-180) than for e-bikes (14-27). PM(2.5) emission factors generally are lower for CVs (gasoline or diesel) than comparable EVs. However, intake fraction is often greater for CVs than for EVs because combustion emissions are generally closer to population centers for CVs (tailpipe emissions) than for EVs (power plant emissions). For most cities, the net result is that primary PM(2.5) environmental health impacts per passenger-km are greater for e-cars than for gasoline cars (3.6× on average), lower than for diesel cars (2.5× on average), and equal to diesel buses. In contrast, e-bikes yield lower environmental health impacts per passenger-km than the three CVs investigated: gasoline cars (2×), diesel cars (10×), and diesel buses (5×). Our findings highlight the importance of considering exposures, and especially the proximity of emissions to people, when evaluating environmental health impacts for EVs.
Mitochondrial disorder caused Charles Darwin’s cyclic vomiting syndrome
Finsterer, Josef; Hayman, John
2014-01-01
Background Charles Darwin (CD), “father of modern biology,” suffered from multisystem illness from early adulthood. The most disabling manifestation was cyclic vomiting syndrome (CVS). This study aims at finding the possible cause of CVS in CD. Methods A literature search using the PubMed database was carried out, and CD’s complaints, as reported in his personal writings and those of his relatives, friends, colleagues, biographers, were compared with various manifestations of mitochondrial disorders (MIDs), known to cause CVS, described in the literature. Results Organ tissues involved in CD’s disease were brain, nerves, muscles, vestibular apparatus, heart, gut, and skin. Cerebral manifestations included episodic headache, visual disturbance, episodic memory loss, periodic paralysis, hysterical crying, panic attacks, and episodes of depression. Manifestations of polyneuropathy included numbness, paresthesias, increased sweating, temperature sensitivity, and arterial hypotension. Muscular manifestations included periods of exhaustion, easy fatigability, myalgia, and muscle twitching. Cardiac manifestations included episodes of palpitations and chest pain. Gastrointestinal manifestations were CVS, dental problems, abnormal seasickness, eructation, belching, and flatulence. Dermatological manifestations included painful lips, dermatitis, eczema, and facial edema. Treatments with beneficial effects to his complaints were rest, relaxation, heat, and hydrotherapy. Conclusion CVS in CD was most likely due to a multisystem, nonsyndromic MID. This diagnosis is based upon the multisystem nature of his disease, the fact that CVS is most frequently the manifestation of a MID, the family history, the variable phenotypic expression between affected family members, the fact that symptoms were triggered by stress, and that only few symptoms could not be explained by a MID. PMID:24453499
NASA Technical Reports Server (NTRS)
Wang, Zuwei; Vaksman, Zalman; Putcha, Lakshmi
2008-01-01
Intranasal scopolamine is a choice drug for the treatment of motion sickness during space flight because of its quick onset of action, short half-life and favorable sideeffects profile. The dose administered usually ranges between 0.1 and 0.4 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids using existing sensitive LC/MS/MS method, especially when the biological sample volumes are limited. To measure scopolamine in human plasma to facilitate pharmacokinetic evaluation of the drug, we developed a sensitive LC/MS/MS method using 96 well micro elution plates for solid phase extraction (SPE) of scopolamine in human plasma. Human plasma (100-250 micro L) were loaded onto Waters Oasis HLB 96 well micro elution plate and eluted with 50 L of organic solvent without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 3 minutes. The mobile phase for separation was 80:20 (v/v) methanol: ammonium acetate (30 mM) in water. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 right arrow 138.1 and internal standard hyoscyamine m/z = 290.2 right arrow 124.1. The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at about 1.1 and 1.7 min respectively. The linear range is 25-10000 pg/mL for scopolamine in human plasma with correlation coefficients greater than 0.99 and CV less than 0.5%. The intra-day and inter-day CVs are less than 15% for quality control samples with concentrations of 75,300, and 750 pg/mL of scopolamine in human plasma. SPE using 96 well micro elution plates allows rapid sample preparation and enhanced sensitivity for the LC/MS/MS determination of scopolamine in a small volume of biological samples. The new method is also cost effective since it uses a small volume of organic solvents compared to the methods using SPE cartridges or regular 96 well SPE plates. This method can be successfully used for bioavailability and pharmacokinetic evaluations of scopolamine, especially when volumes of biological samples are limited. Further investigation to use automated SPE system with 96 well micro elution plates is planned.
A High-Order Finite Spectral Volume Method for Conservation Laws on Unstructured Grids
NASA Technical Reports Server (NTRS)
Wang, Z. J.; Liu, Yen; Kwak, Dochan (Technical Monitor)
2001-01-01
A time accurate, high-order, conservative, yet efficient method named Finite Spectral Volume (FSV) is developed for conservation laws on unstructured grids. The concept of a 'spectral volume' is introduced to achieve high-order accuracy in an efficient manner similar to spectral element and multi-domain spectral methods. In addition, each spectral volume is further sub-divided into control volumes (CVs), and cell-averaged data from these control volumes is used to reconstruct a high-order approximation in the spectral volume. Riemann solvers are used to compute the fluxes at spectral volume boundaries. Then cell-averaged state variables in the control volumes are updated independently. Furthermore, TVD (Total Variation Diminishing) and TVB (Total Variation Bounded) limiters are introduced in the FSV method to remove/reduce spurious oscillations near discontinuities. A very desirable feature of the FSV method is that the reconstruction is carried out only once, and analytically, and is the same for all cells of the same type, and that the reconstruction stencil is always non-singular, in contrast to the memory and CPU-intensive reconstruction in a high-order finite volume (FV) method. Discussions are made concerning why the FSV method is significantly more efficient than high-order finite volume and the Discontinuous Galerkin (DG) methods. Fundamental properties of the FSV method are studied and high-order accuracy is demonstrated for several model problems with and without discontinuities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reid, A.A.; Fleming, P.J.; Lake, C.R.
We modified a norepinephrine radioenzymatic method for determination of plasma phenylpropanolamine (PPA) concentrations. PPA is converted to N(methyl-/sup 3/H)ephedrine ((/sup 3/H)EPD) by the enzyme phenylethanolamine N-methyltransferase (PNMT) and S-(methyl-/sup 3/H)adenosyl-L-methionine ((/sup 3/H)AdoMet). The product, (/sup 3/H)EPD, is isolated from unreacted (/sup 3/H)AdoMet and labeled side products by an organic extraction and a TLC procedure. In addition, a preincubation organic extraction procedure is included to remove inhibitors of PNMT from plasma and to concentrate the sample for enhanced enzymatic conversion. In order to accurately quantitate PPA across the wide range of possible concentrations, the assay is conducted at two plasma volumes.more » PPA concentrations between 0.3 and 50 micrograms/liter can be detected with 1 ml of plasma, while concentrations between 4 and 1500 micrograms/liter can be detected with 0.1 ml of plasma. The intra-assay coefficients of variation (CVs) are 9.3 and 5.7% at 0.5 and 1500 micrograms/liter, respectively, while the mean interassay CV is 13.8%.« less
Cataclysmic variables based on the stellar spectral survey LAMOST DR3
NASA Astrophysics Data System (ADS)
Han, Xianming L.; Zhang, Li-Yun; Shi, Jian-Rong; Pi, Qing-Feng; Lu, Hong-Peng; Zhao, Li-Bo; Terheide, Rachel K.; Jiang, Lin-Yang
2018-06-01
Big data in the form of stellar spectra from the spectroscopic survey associated with the Large Sky Area Multi-object Fiber Spectroscopic Telescope (LAMOST) are important for studying properties of cataclysmic variables (CVs). By cross matching the catalogs of CVs compiled with LAMOST DR3, acquired from October 2011 to July 2015, we obtained the first spectroscopic catalog for CVs observed by LAMOST with high signal to noise ratio, above 8. By integrating line profiles, their equivalent widths (EWs) of the Hα, Hβ, Hγ and Hδ, as well as He I 5876 and 6678 Å lines, were calculated. There were 74 stellar spectra from 48 known CVs and three spectra from three new CV candidates. At the same time, we also collected their previously published EWs. Thirty-three objects had repeated spectra and 30 stars showed spectral variability in the Hα line. Moreover, we carried out photometric follow-up studies for five CVs (UU Aqr, TT Tri, PX And, BP Lyn and RW Tri). We obtained nine new light curves and revised their linear ephemerides. For RW Tri, there is a possible oscillation with an amplitude of 0.0031(2) days and a period of 47.6 ± 0.4 years, which might be caused by a third body (brown dwarf) or magnetic activity cycle.
Bakeas, Evangelos B; Karavalakis, Georgios
2013-02-01
This study investigates the impact of low concentration biodiesel blends on the regulated, carbonyl and PAH emissions from a modern passenger vehicle. The vehicle was a Euro 4 compliant SUV type fitted with a common-rail diesel engine and a diesel oxidation catalyst. Emission and fuel consumption measurements were performed on a chassis dynamometer using a constant volume sampling (CVS) technique, following the European regulations. All measurements were conducted over the NEDC and Artemis driving cycles. Aiming to evaluate the fuel impact on emissions, a soy-based biodiesel was blended with an ultra low sulphur diesel at proportions of 10 and 30% by volume. The experimental results revealed that emissions of PM, HC and CO decreased with biodiesel over most driving conditions. Some increases were observed over the NEDC which may be attributed to the cold-start effect and to certain fuel characteristics. NO x emissions were found to be higher with biodiesel especially during Artemis operation. CO 2 emissions and fuel consumption followed similar patterns and increased with biodiesel. Most carbonyl compound emissions increased with biodiesel, with the exception of aromatic aldehydes. It was found that carbonyl emissions decreased as the mean speed and load of the driving cycle was increased. Most PAH emissions were found to be lower with biodiesel, however, some increases were observed for certain toxic compounds.
Functional characterization of contractile vacuole isolated from Amoeba proteus.
Nishihara, Eri; Shimmen, Teruo; Sonobe, Seiji
2004-12-01
Contractile vacuoles (CVs) released from cells of Amoeba proteus were used to analyze its function in vitro. When CV was transferred to a hypertonic medium, its volume decreased within 10 sec. When it was subsequently returned to its original medium, it quickly started swelling. However, it ruptured before recovering its initial volume. These results suggested that the CV membrane is semi-permeable and that the fluid is collected by the osmotic gradient in vivo. The water permeability of membrane of isolated CV was calculated from the rate of osmotic volume change to be 0.94 microm/sec . OsM. This high value suggested that CV membrane is equipped with water channel. CV contracted (or burst) quickly upon addition of 1 mM ATP. Contraction was induced by ATP, but not by other nucleotides, GTP, ITP, ADP, or the analogues of ATP, AMP-PNP and ATPgammaS. It was suggested that the contraction of isolated CV was caused by increase in the tension of its membrane by ATP.
Syngelaki, Argyro; Pergament, Eugene; Homfray, Tessa; Akolekar, Ranjit; Nicolaides, Kypros H
2014-01-01
To estimate the proportion of other chromosomal abnormalities that could be missed if combined testing was replaced by cell-free (cf) DNA testing as the method of screening for trisomies 21, 18 and 13. The prevalence of trisomies 21, 18 or 13, sex chromosome aneuploidies, triploidy and other chromosomal abnormalities was examined in pregnancies undergoing first-trimester combined screening and chorionic villus sampling (CVS). In 1,831 clinically significant chromosomal abnormalities in pregnancies with combined risk for trisomies 21, 18 and 13≥1:100, the contribution of trisomies 21, 18 or 13, sex chromosome aneuploidies, triploidy and other chromosomal abnormalities at high risk of adverse outcome was 82.9, 8.2, 3.9 and 5.0%, respectively. Combined screening followed by CVS for risk≥1:10 and cfDNA testing for risk 1:11-1:2,500 could detect 97% of trisomy 21 and 98% of trisomies 18 and 13. Additionally, 86% of monosomy X, half of 47,XXY, 47,XYY or 47,XXX, half of other chromosomal abnormalities and one third of triploidies, which are currently detected by combined screening and CVS for risk≥1:100, could be detected. Screening by cfDNA testing, contingent on results of combined testing, improves detection of trisomies, but misses a few of the other chromosomal abnormalities detected by screening with the combined test. © 2014 S. Karger AG, Basel.
Ten steps to writing curriculum vitae covering letters.
Pearce, Chris
2007-12-01
As guides for recruiters, the covering letters of applicants' curricula vitae (CVs) can be almost as important as the CVs themselves. When applying for posts therefore, you should regard the writing of such letters as an opportunity to distinguish yourself from other candidates.
Harris, Breanna N; de Jong, Trynke R; Yang, Vanessa; Saltzman, Wendy
2013-11-01
Stress and chronically elevated glucocorticoid levels have been shown to disrupt parental behavior in mothers; however, almost no studies have investigated corresponding effects in fathers. The present experiment tested the hypothesis that chronic variable stress inhibits paternal behavior and consequently alters pup development in the monogamous, biparental California mouse (Peromyscus californicus). First-time fathers were assigned to one of three experimental groups: chronic variable stress (CVS, n=8), separation control (SC, n=7), or unmanipulated control (UC, n=8). The CVS paradigm (3 stressors per day for 7 days) successfully stressed mice, as evidenced by increased baseline plasma corticosterone concentrations, increased adrenal mass, decreased thymus mass, and a decrease in body mass over time. CVS altered paternal and social behavior of fathers, but major differences were observed only on day 6 of the 7-day paradigm. At that time point, CVS fathers spent less time with their pairmate and pups, and more time autogrooming, as compared to UC fathers; SC fathers spent more time behaving paternally and grooming the female mate than CVS and UC fathers. Thus, CVS blocked the separation-induced increase in social behaviors observed in the SC fathers. Nonetheless, chronic stress in fathers did not appear to alter survival or development of their offspring: pups from the three experimental conditions did not differ in body mass gain over time, in the day of eye opening, or in basal or post-stress corticosterone levels. These results demonstrate that chronic stress can transiently disrupt paternal and social behavior in P. californicus fathers, but does not alter pup development or survival under controlled, non-challenging laboratory conditions. © 2013.
ORIGIN OF THE GALACTIC DIFFUSE X-RAY EMISSION: IRON K-SHELL LINE DIAGNOSTICS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nobukawa, Masayoshi; Uchiyama, Hideki; Nobukawa, Kumiko K.
This paper reports detailed K-shell line profiles of iron (Fe) and nickel (Ni) of the Galactic Center X-ray Emission (GCXE), Galactic Bulge X-ray Emission (GBXE), Galactic Ridge X-ray Emission (GRXE), magnetic Cataclysmic Variables (mCVs), non-magnetic Cataclysmic Variables (non-mCVs), and coronally Active Binaries (ABs). For the study of the origin of the GCXE, GBXE, and GRXE, the spectral analysis is focused on equivalent widths of the Fe i-K α , Fe xxv-He α , and Fe xxvi-Ly α lines. The global spectrum of the GBXE is reproduced by a combination of the mCVs, non-mCVs, and ABs spectra. On the other hand,more » the GRXE spectrum shows significant data excesses at the Fe i-K α and Fe xxv-He α line energies. This means that additional components other than mCVs, non-mCVs, and ABs are required, which have symbiotic phenomena of cold gas and very high-temperature plasma. The GCXE spectrum shows larger excesses than those found in the GRXE spectrum at all the K-shell lines of iron and nickel. Among them the largest ones are the Fe i-K α , Fe xxv-He α , Fe xxvi-Ly α , and Fe xxvi-Ly β lines. Together with the fact that the scale heights of the Fe i-K α , Fe xxv-He α , and Fe xxvi-Ly α lines are similar to that of the central molecular zone (CMZ), the excess components would be related to high-energy activity in the extreme envelopment of the CMZ.« less
Harris, Breanna N.; de Jong, Trynke R.; Yang, Vanessa; Saltzman, Wendy
2013-01-01
Stress and chronically elevated glucocorticoid levels have been shown to disrupt parental behavior in mothers; however, almost no studies have investigated corresponding effects in fathers. The present experiment tested the hypothesis that chronic variable stress inhibits paternal behavior and consequently alters pup development in the monogamous, biparental California mouse (Peromyscus californicus). First-time fathers were assigned to one of three experimental groups: chronic variable stress (CVS, n=8), separation control (SC, n=7), or unmanipulated control (UC, n=8). The CVS paradigm (3 stressors per day for 7 days) successfully stressed mice, as evidenced by increased baseline plasma corticosterone concentrations, increased adrenal mass, decreased thymus mass, and a decrease in body mass over time. CVS altered paternal and social behavior of fathers, but major differences were observed only on day 6 of the 7-day paradigm. At that time point, CVS fathers spent less time with their pairmate and pups, and more time autogrooming, as compared to UC fathers; SC fathers spent more time behaving paternally and grooming the female mate than CVS and UC fathers. Thus, CVS blocked the separation-induced increase in social behaviors observed in the SC fathers. Nonetheless, chronic stress in fathers did not appear to alter survival or development of their offspring: pups from the three experimental conditions did not differ in body mass gain over time, in day of eye opening, or in basal or post-stress corticosterone levels. These results demonstrate that chronic stress can transiently disrupt paternal and social behavior in P. californicus fathers, but does not alter pup development or survival under controlled, nonchallenging laboratory conditions. PMID:24157379
Almeida, Jeferson; Duarte, Josiane O; Oliveira, Leandro A; Crestani, Carlos C
2015-01-01
Comorbidity between mood disorders and cardiovascular disease has been described extensively. However, available antidepressants can have cardiovascular side effects. Treatment with selective inhibitors of neuronal nitric oxide synthase (nNOS) induces antidepressant effects, but whether the antidepressant-like effects of these drugs are followed by cardiovascular changes has not been previously investigated. Here, we tested in male rats exposed to chronic variable stress (CVS) the hypothesis that nNOS blockers are advantageous compared with conventional antidepressants in terms of cardiovascular side effects. We compared the effects of chronic treatment with the preferential nNOS inhibitor 7-nitroindazole (7-NI) with those evoked by the conventional antidepressant fluoxetine on alterations that are considered as markers of depression (immobility in the forced swimming test, FST, decreased body weight gain and increased plasma corticosterone concentration) and cardiovascular changes caused by CVS. Rats were exposed to a 14-day CVS protocol, while being concurrently treated daily with either 7-NI (30 mg/kg) or fluoxetine (10 mg/kg). Fluoxetine and 7-NI prevented the increase in immobility in the FST induced by CVS and reduced plasma corticosterone concentration in stressed rats. Both these treatments also prevented the CVS-evoked reduction of the depressor response to vasodilator agents and baroreflex changes. Fluoxetine and 7-NI-induced cardiovascular changes independent of stress exposure, including cardiac autonomic imbalance, increased intrinsic heart rate and vascular sympathetic modulation, a reduction of the pressor response to vasoconstrictor agents, and impairment of baroreflex activity. Altogether, these findings provide evidence that fluoxetine and 7-NI have similar effects on the depression-like state induced by CVS and on cardiovascular function.
Searching Cyclical Period Variations in Cataclysmic Variable Stars
NASA Astrophysics Data System (ADS)
Borges, B. W.; Baptista, R.
2006-08-01
Cataclymic variables (CVs) are semi-detached binary systems in which a main sequence late-type star (the secondary) fills its Roche lobe and transfers matter to a white dwarf (the primary) through the inner Lagragian point L[1]. Evolutive models of CVs predicts that the orbital periods P[orb] of these systems would decrease on time scales of 10^8-10^9 years due to angular momentum losses either by magnetic braking via the secondary star's wind (P [orb] > 3 hr) or by emission of gravitational radiation (P[orb] < 3 hr). These models try to explain the observed gap of systems with P[orb] in the range of ~ 2 to 3 hr as the consequence of a sharp reduction of magnetic field open lines when the secondary star become fully convective (at P[orb] ~ 3 hr). However, up to now no well-studied CVs shows evidence of period decrease. Instead, most well-observed eclipsing CVs show cyclical period changes probably associated to solar-type (quasi-periodic and/or multiperiodic) magnetic activity cycles in the secondary star. The fast spinning secondaries of CVs, covering a range of masses and rotation periods, are an important laboratory to understanding magnetic activities cycles in late type stars. In the present work, we report some results of the search of cyclical period in four Cvs: V4140 Sgr, V2051 Oph, UU Aqr and IP Peg. Both V4140 Sgr and V2051 Oph show modulation periods of 22 yr and 7 yr respectively. A discussion of the distinct magnetic activity properties of short and long orbital period (P[orb] < 3 hr and P[orb] > 3 hr, respectively) systems in the framework of the CV evolution scenarios is presented.
Samsuddin, Niza; Rampal, Krishna Gopal; Ismail, Noor Hassim; Abdullah, Nor Zamzila; Nasreen, Hashima E
2016-02-01
Research findings have linked exposure to pesticides to an increased risk of cardiovascular (CVS) diseases. Therefore, this study aimed to assess the impact of chronic mix-pesticides exposure on CVS hemodynamic parameters. A total of 198 male Malay pesticide-exposed and 195 male Malay nonexposed workers were examined. Data were collected through exposure-matrix assessment, questionnaire, blood analyses, and CVS assessment. Explanatory variables comprised of lipid profiles, paraoxonase 1 (PON1), and oxidized low-density lipoprotein (ox-LDL). Outcome measures comprised of brachial and aortic diastolic blood pressure (DBP) and systolic BP (SBP), heart rate, and pulse wave velocity (PWV). Linear regressions identified the B coefficient showing how many units of CVS parameters are associated with each unit of covariates. Diazoxonase was significantly lower and ox-LDL was higher among pesticide-exposed workers than the comparison group. The final multivariate linear regression model revealed that age, body mass index (BMI), smoking, and pesticide exposure were independent predictors of brachial and aortic DBP and SBP. Pesticide exposure was also associated with heart rate, but not with PWV. Lipid profiles, PON1 enzymes, and ox-LDL showed no association with any of the CVS parameters. Chronic mix-pesticide exposure among workers involved in mosquito control has possible association with depression of diazoxonase and the increase in ox-LDL, brachial and aortic DBP and SBP, and heart rate. This study raises concerns that those using pesticides may be exposed to hitherto unrecognized CVS risks among others. If this is confirmed by further studies, greater efforts will be needed to protect these workers. © American Journal of Hypertension, Ltd 2015. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Far-ultraviolet observation of the globular cluster NGC 6397
NASA Astrophysics Data System (ADS)
Dieball, A.; Rasekh, A.; Knigge, C.; Shara, M.; Zurek, D.
2017-07-01
We present an observational far-ultraviolet (FUV) and near-ultraviolet (NUV) study of the core region of the globular cluster (GC) NGC 6397. The observations were obtained with the Space Telescope Imaging Spectrograph (STIS, FUV) and the Wide Field Camera 3 (NUV) on board the Hubble Space Telescope. Here, we focus on the UV-bright stellar populations such as blue stragglers (BSs), white dwarfs (WDs) and cataclysmic variables (CVs). We present the first FUV - NUV colour-magnitude diagram (CMD) for this cluster. To support our classification of the stellar populations, we compare our FUV - NUV CMD with optical data from the ACS Survey of Galactic Globular Clusters. The FUV - NUV CMD indicates 16 sources located in the WD area, and 10 BSs within the 25 × 25 arcsec2 of the STIS FUV data. 18 Chandra X-ray sources are located within the FUV field of view. 13 of those have an NUV counterpart, of which 9 sources also have an FUV counterpart. Out of those, five sources are previously suggested CVs, and indeed, all five are located in the WD/CV region in our FUV - NUV CMD. Another CV has only an FUV but no NUV counterpart. We also detect an NUV (but no FUV) counterpart to the millisecond pulsar (MSP) located in the core of this cluster. The NUV light curves of the CVs and MSP show flickering behaviour typical of CVs. We found that the BSs and CVs are the most centrally concentrated populations. This might be an effect of mass segregation or it might indicate the preferred birth place of BSs and CVs via dynamical interactions in the dense core region of GCs. Horizontal branch stars are the least centrally concentrated population and absent in the innermost area of the core.
IRCAD recommendation on safe laparoscopic cholecystectomy.
Conrad, Claudius; Wakabayashi, Go; Asbun, Horacio J; Dallemagne, Bernard; Demartines, Nicolas; Diana, Michele; Fuks, David; Giménez, Mariano Eduardo; Goumard, Claire; Kaneko, Hironori; Memeo, Riccardo; Resende, Alexandre; Scatton, Olivier; Schneck, Anne-Sophie; Soubrane, Olivier; Tanabe, Minoru; van den Bos, Jacqueline; Weiss, Helmut; Yamamoto, Masakazu; Marescaux, Jacques; Pessaux, Patrick
2017-11-01
An expert recommendation conference was conducted to identify factors associated with adverse events during laparoscopic cholecystectomy (LC) with the goal of deriving expert recommendations for the reduction of biliary and vascular injury. Nineteen hepato-pancreato-biliary (HPB) surgeons from high-volume surgery centers in six countries comprised the Research Institute Against Cancer of the Digestive System (IRCAD) Recommendations Group. Systematic search of PubMed, Cochrane, and Embase was conducted. Using nominal group technique, structured group meetings were held to identify key items for safer LC. Consensus was achieved when 80% of respondents ranked an item as 1 or 2 (Likert scale 1-4). Seventy-one IRCAD HPB course participants assessed the expert recommendations which were compared to responses of 37 general surgery course participants. The IRCAD recommendations were structured in seven statements. The key topics included exposure of the operative field, appropriate use of energy device and establishment of the critical view of safety (CVS), systematic preoperative imaging, cholangiogram and alternative techniques, role of partial and dome-down (fundus-first) cholecystectomy. Highest consensus was achieved on the importance of the CVS as well as dome-down technique and partial cholecystectomy as alternative techniques. The put forward IRCAD recommendations may help to promote safe surgical practice of LC and initiate specific training to avoid adverse events. © 2017 Japanese Society of Hepato-Biliary-Pancreatic Surgery.
Prenatal diagnosis of xeroderma pigmentosum group A in Japan.
Moriwaki, Shinichi; Yamashita, Yoshiki; Nakamura, Sachiko; Fujita, Daisuke; Kohyama, Jun; Takigawa, Masahiro; Ohmichi, Masahide
2012-06-01
We performed a prenatal diagnosis for 10 fetuses from nine unrelated Japanese xeroderma pigmentosum complementation group A (XP-A) families. All parents had at least one XP-A child (proband) with a homozygous founder mutation (IVS3-1G>C) in the XPA gene. A genetic analysis was performed by a restriction enzyme; AlwNI fragment length polymorphism of polymerase chain reaction (PCR)-amplified DNA, mostly from amniotic fluid (AF) and cultured cells established from AF. However, for the first family, we tried amniocentesis as well as chorionic villus sampling (CVS). Among the 10 cases, we confirmed the results of PCR-based genetic diagnosis by post-ultraviolet survival of amniotic cells in eight cases. Unfortunately, 6 weeks after CVS and 4 days after the amniocentesis in the first case we examined, the fetus died in utero, the reason for which remains unexplained. We prenatally determined two XP-A cases, six XP-A carriers and two wild-type fetuses, which appears to be consistent with Mendel's law. © 2011 Japanese Dermatological Association.
Measuring user acceptance of and willingness-to-pay for CVI technology : final research report.
DOT National Transportation Integrated Search
2016-09-30
The increased prevalence of Connected Vehicles (CVs) is expected to provide significant safety : benefits to roadway users. Estimates indicate that the use of CVs will reduce non-impaired driver : crashes by 80 percent. To ensure that the full benefi...
Sedda, A; Tonin, D; Salvato, G; Gandola, M; Bottini, G
2016-04-01
Homeostatic parameters, such as temperature, are related to body representation. In this study, we measured whether caloric vestibular stimulation (CVS) alters body temperature and tactile processing, and if in the direction predicted by a holistic body matrix representation. Skin temperature and tactile two-point discrimination (TPD) acuity were measured for both arms before, immediately after and with a delay from CVS. Participants were also administered a personality questionnaire and an anxiety inventory to rule out confounding factors. Two control experiments were planned to exclude casual variations. Our results show that temperature drops significantly in both arms after CVS. CVS also induces a bilateral improvement in tactile acuity (even though not immediately after but in the delayed condition). Finally, these effects are not due to learning, as demonstrated by the control experiment. In summary, our results suggest that vestibular stimulation updates body representation, supporting the evidence in favor of a body matrix. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Belloni, Diogo; Schreiber, Matthias R.; Zorotovic, Mónica; Iłkiewicz, Krystian; Hurley, Jarrod R.; Giersz, Mirek; Lagos, Felipe
2018-06-01
The predicted and observed space density of cataclysmic variables (CVs) have been for a long time discrepant by at least an order of magnitude. The standard model of CV evolution predicts that the vast majority of CVs should be period bouncers, whose space density has been recently measured to be ρ ≲ 2 × 10-5 pc-3. We performed population synthesis of CVs using an updated version of the Binary Stellar Evolution (BSE) code for single and binary star evolution. We find that the recently suggested empirical prescription of consequential angular momentum loss (CAML) brings into agreement predicted and observed space densities of CVs and period bouncers. To progress with our understanding of CV evolution it is crucial to understand the physical mechanism behind empirical CAML. Our changes to the BSE code are also provided in details, which will allow the community to accurately model mass transfer in interacting binaries in which degenerate objects accrete from low-mass main-sequence donor stars.
Levinson, Pauline; Choi, Robert Y.; Cole, Amy L.; Hirbod, Taha; Rhedin, Samuel; Payne, Barbara; Guthrie, Brandon L.; Bosire, Rose; Cole, Alexander M.; Farquhar, Carey; Broliden, Kristina
2012-01-01
Background HIV exposed seronegative (HESN) women represent the population most in need of a prophylactic antiviral strategy. Mucosal cationic polypeptides can potentially be regulated for this purpose and we here aimed to determine their endogenous expression and HIV neutralizing activity in genital secretions of women at risk of HIV infection. Methodology/Principal Findings Cervicovaginal secretions (CVS) of Kenyan women in HIV-serodiscordant relationships (HESN, n = 164; HIV seropositive, n = 60) and low-risk controls (n = 72) were assessed for the cationic polypeptides HNP1–3, LL-37 and SLPI by ELISA and for HIV neutralizing activity by a PBMC-based assay using an HIV primary isolate. Median levels of HNP1–3 and LL-37 in CVS were similar across study groups. Neither HSV-2 serostatus, nor presence of bacterial vaginosis, correlated with levels of HNP1–3 or LL-37 in the HESN women. However, an association with their partner's viral load was observed. High viral load (>10,000 HIV RNA copies/ml plasma) correlated with higher levels of HNP1–3 and LL-37 (p = 0.04 and 0.03, respectively). SLPI was most abundant in the low-risk group and did not correlate with male partner's viral load in the HESN women. HIV neutralizing activity was found in CVS of all study groups. In experimental studies, selective depletion of cationic polypeptides from CVS rendered the remaining CVS fraction non-neutralizing, whereas the cationic polypeptide fraction retained the activity. Furthermore, recombinant HNP1–3 and LL-37 could induce neutralizing activity when added to CVS lacking intrinsic activity. Conclusions/Significance These findings show that CVS from HESN, low-risk, and HIV seropositive women contain HIV neutralizing activity. Although several innate immune proteins, including HNP1–3 and LL-37, contribute to this activity these molecules can also have inflammatory properties. This balance is influenced by hormonal and environmental factors and in the present HIV serodiscordant couple cohort study we show that a partner's viral load is associated with levels of such molecules. PMID:22389677
Lopez-Trigo, Paula; Khanfar, Nile M; Alameddine, Sarah; Harrington, Catherine
2015-01-01
CVS Health has taken a strategic marketing move by banning tobacco sales. They risk losing customers who buy medications and cigarettes at their drugstores. They estimate they will lose 2 billion dollars by banning cigarette sales. CVS Health believes they will benefit from being regarded as health care partner by insurers and banning cigarette sales is an important step in being recognized as such. The Affordable Care Act expanded access to pharmacy-based medical clinics, increased affordability of medications, and expanded the clinical role of pharmacists. CVS Health is positioning itself to take advantage of these changes.
The relationship between CK and CV chondrites
NASA Astrophysics Data System (ADS)
Greenwood, R. C.; Franchi, I. A.; Kearsley, A. T.; Alard, O.
2010-03-01
CK chondrites are highly oxidized meteorites containing abundant magnetite and trace amounts of Fe,Ni metal. Although the group is predominately composed of equilibrated meteorites (types 4-6), in recent years a significant number of new samples have been classified as being either CK3 or CK3-anomalous. These unequilibrated CKs often display a close affinity with members of the CV oxidized subgroup. CKs and CVs (oxidized subgroup) may therefore form a continuum and by implication could be derived from a single common parent body. To investigate the relationship between these two groups a detailed study of the oxygen isotope composition, opaque mineralogy and major and trace element geochemistry of a suite of CV and CK chondrites has been undertaken. The results of oxygen isotope analysis confirm the close affinity between CV and CK chondrites, while excluding the possibility of a linkage between the CO and CK groups. Magnetites in both CV and CK chondrites show significant compositional similarities, but high Ti contents are a diagnostic feature of the latter group. The results of major and trace element analysis demonstrate that both CV and CK chondrites show overlapping variation. Supporting evidence for a single common source for both groups comes from their similar cosmic-ray exposure age distributions. Recent reflectance spectral analysis is consistent with both the CVs and CKs being derived from Eos family asteroids, which are believed to have formed by the catastrophic disruption of a single large asteroid. Thus, a range of evidence appears to be consistent with CV and CK chondrites representing samples from a single thermally stratified parent body. In view of the close similarity between CV and CK chondrites some modification of the present classification scheme may be warranted, possibly involving integration of the two groups. One means of achieving this would be to reassigned CK chondrites to a subgroup of the oxidized CVs. It is recognized that a full evaluation of this proposal may require further study of the still poorly understood CK3 chondrites.
Intramyocellular lipid quantification: repeatability with 1H MR spectroscopy.
Torriani, Martin; Thomas, Bijoy J; Halpern, Elkan F; Jensen, Megan E; Rosenthal, Daniel I; Palmer, William E
2005-08-01
To prospectively determine the repeatability and variability of tibialis anterior intramyocellular lipid (IMCL) quantifications performed by using 1.5-T hydrogen 1 (1H) magnetic resonance (MR) spectroscopy in healthy subjects. Institutional review board approval and written informed consent were obtained for this Health Insurance Portability and Accountability Act-compliant study. The authors examined the anterior tibial muscles of 27 healthy subjects aged 19-48 years (12 men, 15 women; mean age, 25 years) by using single-voxel short-echo-time point-resolved 1H MR spectroscopy. During a first visit, the subjects underwent 1H MR spectroscopy before and after being repositioned in the magnet bore, with voxels carefully placed on the basis of osseous landmarks. Measurements were repeated after a mean interval of 12 days. All spectra were fitted by using Java-based MR user interface (jMRUI) and LCModel software, and lipid peaks were scaled to the unsuppressed water peak (at 4.7 ppm) and the total creatine peak (at approximately 3.0 ppm). A one-way random-effects variance components model was used to determine intraday and intervisit coefficients of variation (CVs). A power analysis was performed to determine the detectable percentage change in lipid measurements for two subject sample sizes. Measurements of the IMCL methylene protons peak at a resonance of 1.3 ppm scaled to the unsuppressed water peak (IMCL(W)) that were obtained by using jMRUI software yielded the lowest CVs overall (intraday and intervisit CVs, 13.4% and 14.4%, respectively). The random-effects variance components model revealed that nonbiologic factors (equipment and repositioning) accounted for 50% of the total variability in IMCL quantifications. Power analysis for a sample size of 20 subjects revealed that changes in IMCL(W) of greater than 15% could be confidently detected between 1H MR spectroscopic measurements obtained on different days. 1H MR spectroscopy is feasible for repeatable quantification of IMCL concentrations in longitudinal studies of muscle metabolism.
NASA Astrophysics Data System (ADS)
Papanicolaou, A. N. (Thanos); Wacha, Kenneth M.; Abban, Benjamin K.; Wilson, Christopher G.; Hatfield, Jerry L.; Stanier, Charles O.; Filley, Timothy R.
2015-11-01
Most available biogeochemical models focus within a soil profile and cannot adequately resolve contributions of the lighter size fractions of organic rich soils for enrichment ratio (ER) estimates, thereby causing unintended errors in soil organic carbon (SOC) storage predictions. These models set ER as constant, usually equal to unity. The goal of this study is to provide spatiotemporal predictions of SOC stocks at the hillslope scale that account for the selective entrainment and deposition of lighter size fractions. It is hypothesized herein that ER values may vary depending on hillslope location, Land Use/Land Cover (LULC) conditions, and magnitude of the hydrologic event. An ER module interlinked with two established models, CENTURY and Watershed Erosion Prediction Project, is developed that considers the effects of changing runoff coefficients, bare soil coverage, tillage depth, fertilization, and soil roughness on SOC redistribution and storage. In this study, a representative hillslope is partitioned into two control volumes (CVs): a net erosional upslope zone and a net depositional downslope zone. We first estimate ER values for both CVs I and II for different hydrologic and LULC conditions. Second, using the improved ER estimates for the two CVs, we evaluate the effects that management practices have on SOC redistribution during different crop rotations. Overall, LULC promoting less runoff generally yielded higher ER values, which ranged between 0.97 and 3.25. Eroded soils in the upland CV were up to 4% more enriched in SOC than eroded soils in the downslope CV due to larger interrill contributions, which were found to be of equal importance to rill contributions. The chronosequence in SOC storage for the erosional zone revealed that conservation tillage and enhanced crop yields begun in the 1980s reversed the downward trend in SOC losses, causing nearly 26% of the lost SOC to be regained.
NASA Technical Reports Server (NTRS)
Yorio, Neil C.; Wheeler, Raymond M.; Weigel, Russell C.
1995-01-01
Growth measurements were taken of potato plantlets (Solanum tuberosum L.) cvs. Norland (NL), Denali (DN), and Kennebec (KN), grown in vitro. Studies were conducted in a growth chamber, with nodal explants grown for 21 days on Murashige and Skoog salts with either 0, 1, 2, or 3% sucrose and capped with loose-fitted Magenta 2-way caps that allowed approximately 2.25 air exchanges/hour. Plantlets were exposed to either 100 or 300 micro mol/sq m/s photosynthetic photon flux (PPF), and the growth chamber was maintained at either 400 or 4000 micro mol/mol CO2. Regardless of PPF, all cvs. that were grown at 4000 micro mol/mol CO2 showed significant increases in total plantlet dry weight (TDW) and shoot length (SL) when sucrose was omitted from the media, indicating an autotrophic response. At 400 micro mol/mol CO2, all cvs. showed an increase in TDW and SL with increasing sucrose under both PPF levels. Within any sucrose treatment, the highest TDW for all cvs. resulted from 300 micro mol/sq m/s PPF and 4000 micro mol/mol CO2 At 4000 micro mol/mol CO2, TDW showed no further increase with sucrose levels above 1% for cvs. NL and DN at both PPF levels, suggesting that sucrose levels greater than 1% may hinder growth when CO2 enrichment is used.
Clinical efficacy of Ayurvedic management in computer vision syndrome: A pilot study.
Dhiman, Kartar Singh; Ahuja, Deepak Kumar; Sharma, Sanjeev Kumar
2012-07-01
Improper use of sense organs, violating the moral code of conduct, and the effect of the time are the three basic causative factors behind all the health problems. Computer, the knowledge bank of modern life, has emerged as a profession causing vision-related discomfort, ocular fatigue, and systemic effects. Computer Vision Syndrome (CVS) is the new nomenclature to the visual, ocular, and systemic symptoms arising due to the long time and improper working on the computer and is emerging as a pandemic in the 21(st) century. On critical analysis of the symptoms of CVS on Tridoshika theory of Ayurveda, as per the road map given by Acharya Charaka, it seems to be a Vata-Pittaja ocular cum systemic disease which needs systemic as well as topical treatment approach. Shatavaryaadi Churna (orally), Go-Ghrita Netra Tarpana (topically), and counseling regarding proper working conditions on computer were tried in 30 patients of CVS. In group I, where oral and local treatment was given, significant improvement in all the symptoms of CVS was observed, whereas in groups II and III, local treatment and counseling regarding proper working conditions, respectively, were given and showed insignificant results. The study verified the hypothesis that CVS in Ayurvedic perspective is a Vata-Pittaja disease affecting mainly eyes and body as a whole and needs a systemic intervention rather than topical ocular medication only.
Sanjay, Pandanaboyana; Fulke, Jennifer L; Exon, David J
2010-08-01
The study aims to evaluate the use of "critical view of safety" (CVS) for the prevention of bile duct injuries during laparoscopic cholecystectomy for acute biliary pathology as an alternative to routine intraoperative cholangiography (IOC). A policy of routine CVS to identify biliary anatomy and selective IOC for patients suspected to have common bile duct (CBD) stone was adopted. Receiver operator curves (ROCs) were used to identify cutoff values predicting CBD stones. Four hundred forty-seven consecutive, same admission laparoscopic cholecystectomies performed between August 2004 and July 2007 were reviewed. CVS was achieved in 388 (87%) patients. Where CVS was not possible, the operation was completed open. CBD stones were identified in 22/57 patients who underwent selective IOC. Preoperative liver function and CBD diameter were significantly higher in those with CBD stones (P < .001). ROC curve analysis identified preoperative cutoff values of bilirubin (35 mumol/L), alkaline phosphatase (250 IU/L), alanine aminotransferase (240 IU/L), and a CBD diameter of 10 mm, as predictive of CBD stones. No bile duct injuries occurred in this series. In acute biliary pathology, the use of CVS helps clarify the anatomy of Calot's triangle and is a suitable alternative to routine IOC. Selective cholangiography should be employed when preoperative liver function and CBD diameter are above defined thresholds.
National survey on internal quality control for tumour markers in clinical laboratories in China.
Wang, Wei; Zhong, Kun; Yuan, Shuai; He, Falin; Du, Yuxuan; Hu, Zhehui; Wang, Zhiguo
2018-06-15
This survey was initiated to obtain knowledge on the current situation of internal quality control (IQC) practice for tumour markers (TMs) in China. Additionally, we tried to acquire the most appropriate quality specifications. This survey was a current status survey. The IQC information had been collected via online questionnaires. All of 1821 clinical laboratories which participated in the 2016 TMs external quality assessment (EQA) programme had been enrolled. The imprecision evaluation criteria were the minimal, desirable, and optimal allowable imprecisions based on biological variations, and 1/3 total allowable error (TEa) and 1/4 TEa. A total of 1628 laboratories answered the questionnaires (89%). The coefficients of variation (CVs) of the IQC of participant laboratories varied greatly from 1% (5 th percentile) to 13% (95 th percentile). More than 82% (82 - 91%) of participant laboratories two types of CVs met 1/3 TEa except for CA 19-9. The percentiles of current CVs were smaller than cumulative CVs. A number of 1240 laboratories (76%) reported their principles and systems used. The electrochemiluminescence was the most used principle (45%) and had the smallest CVs. The performance of laboratories for TMs IQC has yet to be improved. On the basis of the obtained results, 1/3 TEa would be realistic and attainable quality specification for TMs IQC for clinical laboratories in China.
NASA Astrophysics Data System (ADS)
Borges, B. W.; Baptista, R.
2005-09-01
Cataclymic variables (CVs) are semi-detached binary systems in which a main sequence late-type star (the secondary) fills its Roche lobe and transfers matter to a white dwarf (the primary) through the inner Lagragian point L1. Evolutive models of CVs predicts that the orbital periods Porb of these systems would decrease on time scales of 108 - 109 years due to angular momentum losses either by magnetic braking via the secondary star's wind (Porb > 3 hr) or by emission of gravitational radiation (Porb > 3 hr). These models try to explain the observed gap of systems with Porb in the range of ~ 2 to 3 hr as the consequence of a sharp reduction of magnetic field open lines when the secondary star become fully convective (at Porb ~ 3 hr). However, up to now no well-studied CVs show evidence of period decrease. Instead, most well-observed eclipsing CVs show cyclical period changes probably associated to solar-type (quasi-periodic and/or multiperiodic) magnetic activity cycles in the secondary star. The fast spinning secondaries of CVs, covering a range of masses and rotation periods, are an important laboratory to understand magnetic activities cycles in late type stars. In the present work, we report the investigation of cyclical period changes in IP Peg: CV with orbital periods of 3.8 hr.
Clinical efficacy of Ayurvedic management in computer vision syndrome: A pilot study
Dhiman, Kartar Singh; Ahuja, Deepak Kumar; Sharma, Sanjeev Kumar
2012-01-01
Improper use of sense organs, violating the moral code of conduct, and the effect of the time are the three basic causative factors behind all the health problems. Computer, the knowledge bank of modern life, has emerged as a profession causing vision-related discomfort, ocular fatigue, and systemic effects. Computer Vision Syndrome (CVS) is the new nomenclature to the visual, ocular, and systemic symptoms arising due to the long time and improper working on the computer and is emerging as a pandemic in the 21st century. On critical analysis of the symptoms of CVS on Tridoshika theory of Ayurveda, as per the road map given by Acharya Charaka, it seems to be a Vata–Pittaja ocular cum systemic disease which needs systemic as well as topical treatment approach. Shatavaryaadi Churna (orally), Go-Ghrita Netra Tarpana (topically), and counseling regarding proper working conditions on computer were tried in 30 patients of CVS. In group I, where oral and local treatment was given, significant improvement in all the symptoms of CVS was observed, whereas in groups II and III, local treatment and counseling regarding proper working conditions, respectively, were given and showed insignificant results. The study verified the hypothesis that CVS in Ayurvedic perspective is a Vata–Pittaja disease affecting mainly eyes and body as a whole and needs a systemic intervention rather than topical ocular medication only. PMID:23723647
Computer Vision Syndrome: Implications for the Occupational Health Nurse.
Lurati, Ann Regina
2018-02-01
Computers and other digital devices are commonly used both in the workplace and during leisure time. Computer vision syndrome (CVS) is a new health-related condition that negatively affects workers. This article reviews the pathology of and interventions for CVS with implications for the occupational health nurse.
40 CFR 86.219-94 - CVS calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1994 and Later Model Year Gasoline-Fueled New Light-Duty Vehicles, New Light-Duty Trucks and New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.219-94 CVS calibration. The provisions of § 86.119...
2. AERIAL VIEW EXUSS HORNET CVS12 LOOKING PORT TO STARBOARD, ...
2. AERIAL VIEW EX-USS HORNET CVS-12 LOOKING PORT TO STARBOARD, THREE MINECRAFT MORRED ALONGSIDE ON PORT AFT QUARTER. OTHER INACTIVE SHIPS IN BACKGROUND, PUGET SOUND NAVEL SHIPYARD TO LEFT SIDE OF PHOTO. - U.S.S. HORNET, Puget Sound Naval Shipyard, Sinclair Inlet, Bremerton, Kitsap County, WA
Hibernating black holes revealed by photometric mass functions
NASA Astrophysics Data System (ADS)
Casares, Jorge
2018-02-01
We present a novel strategy to uncover the Galactic population of quiescent black holes (BHs). This is based on a new concept, the photometric mass function (PMF), which opens up the possibility of an efficient identification of dynamical BHs in large fields-of-view. This exploits the width of the disc H α emission line, combined with orbital period information. We here show that H α widths can be recovered using a combination of customized H α filters. By setting a width cut-off at 2200 km s-1 we are able to cleanly remove other Galactic populations of H α emitters, including ∼99.9 per cent of cataclysmic variables (CVs). Only short-period (Porb <2.1 h) eclipsing CVs and AGNs will contaminate the sample but these can be easily flagged through photometric variability and, in the latter case, also mid-IR colours. We also describe the strategy of a deep (r = 22) Galactic plane survey based on the concept of PMFs: HAWKs, the HAlpha-Width Kilo-deg Survey. We estimate that ∼800 deg2 are required to unveil ∼50 new dynamical BHs, a three-fold improvement over the known population. For comparison, a century would be needed to produce an enlarged sample of 50 dynamical BHs from X-ray transients at the current discovery rate.
Gamma-ray emission from Cataclysmic variables. 1: The Compton EGRET survey
NASA Technical Reports Server (NTRS)
Schlegel, Eric M.; Barrett, Paul E.; De Jager, O. C.; Chanmugam, G.; Hunter, S.; Mattox, J.
1995-01-01
We report the results of the first gamma-ray survey of cataclysmic variables (CVs) using observations obtained with the Energetic Gamma Ray Experiment Telescope (EGRET) instrument on the Compton Observatory. We briefly describe the theoretical models that are applicable to gamma-ray emission from CVs. These models are particularly relevant to magnetic CVs containing asynchronously rotating white dwarfs. No magnetic CV was detected with an upper limit on the flux at 1 GeV of approximately 2 x 10(exp -8)/sq cm/sec, which corresponds to an upper limit on the gamma-ray luminosity of approximately 10(exp 31) ergs/sec, assuming a typical CV distance of 100 pc.
Vintzileos, A M; Ananth, C V; Fisher, A J; Smulian, J C; Day-Salvatore, D; Beazoglou, T
1998-04-01
To determine 1) the diagnostic accuracy requirements of first-trimester genetic sonography from the cost-benefit point of view and 2) the economic impact of first-trimester genetic sonography for the United States on the basis of the accuracy of previously published studies. A cost-benefit equation was developed on the basis of the hypothesis that the cost of chorionic villus sampling (CVS) in pregnant women with advanced maternal age (at least 35 years old) should be at least equal to the cost of genetic sonography with CVS used only for those with abnormal ultrasound results. The components of the equation included the diagnostic accuracy of genetic ultrasound (sensitivity and specificity for detecting Down syndrome), the costs of the CVS package and genetic ultrasound, and the lifetime cost of Down syndrome cases. First-trimester genetic sonography was found to be beneficial if the overall sensitivity for detecting Down syndrome was greater than 70%, and even then, the cost-benefit ratio depended on the corresponding false-positive rate. The required minimum ultrasound sensitivity varied according to the maternal age-specific prevalence of Down syndrome and ranged between 40% (for women 35 years old) to 96% (for women 44 years old). Of eight published cohorts using nuchal translucency thickness for genetic sonography, five had accuracies of genetic ultrasound compatible with net benefits. The benefits of first-trimester genetic sonography depend on its diagnostic accuracy. First-trimester genetic sonography has the potential for annual savings of 22 million dollars in the United States.
Genome Diversity and Intra- and Inter-Species Recombination Events in Grapevine fanleaf virus
USDA-ARS?s Scientific Manuscript database
Grapevine fanleaf virus (GFLV) was documented in four wine grape (Vitis vinifera) cultivars grown as own-rooted vines. GFLV was found as a mixed virus infection in cvs. Pinot Noir and Chardonnay, but not in cvs. Merlot and Cabernet Franc. Fanleaf disease symptoms were observed only in the first two...
76 FR 49453 - CVS Pharmacy, Inc., Provisional Acceptance of a Settlement Agreement and Order
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-10
...; telephone (301) 504-7612. SUPPLEMENTARY INFORMATION: The text of the Agreement and Order appears below... hooded fleece jackets with drawstrings at the neck (``Jackets''). 5. CVS sold the Jackets, and/or held... (``Guidelines'') to help prevent children from strangling or entangling on neck and waist drawstrings. The...
Effects of Terminological Concreteness on Middle-School Students' Learning of Experimental Design
ERIC Educational Resources Information Center
Siler, Stephanie Ann; Klahr, David
2016-01-01
One obstacle to understanding abstract concepts such as the "control of variables" strategy (CVS) is the tendency for learners to focus on surface rather than deep features in instructional materials. However, in tasks such as learning CVS, these same surface features may also support understanding, provided learners realize the…
[Almost an autobiography: a study of social scientists in health based on the Lattes Curriculum].
do Nascimento, Juliana Luporini; Nunes, Everardo Duarte
2014-04-01
Among the various ways of adopting the biographical approach, we used the curriculum vitaes (CVs) of Brazilian researchers who work as social scientists in health as our research material. These CVs are part of the Lattes Platform of CNPq - the National Council for Scientific and Technological Development, which includes Research and Institutional Directories. We analyzed 238 CVs for this study. The CVs contain, among other things, the following information: professional qualifications, activities and projects, academic production, participation in panels for the evaluation of theses and dissertations, research centers and laboratories and a summarized autobiography. In this work there is a brief review of the importance of autobiography for the social sciences, emphasizing the CV as a form of "autobiographical practice." We highlight some results, such as it being a group consisting predominantly of women, graduates in social sciences, anthropology, sociology or political science, with postgraduate degrees. The highest concentration of social scientists is located in Brazil's southern and southeastern regions. In some institutions the main activities of social scientists are as teachers and researchers with great thematic diversity in research.
Moliner Martínez, Y; Muñoz-Ortuño, M; Herráez-Hernández, R; Campíns-Falcó, P
2014-02-01
This paper describes a new approach for the determination of fat in the effluents generated by the dairy industry which is based on the retention of fat in nylon membranes and measurement of the absorbances on the membrane surface by ATR-IR spectroscopy. Different options have been evaluated for retaining fat in the membranes using milk samples of different origin and fat content. Based on the results obtained, a method is proposed for the determination of fat in effluents which involves the filtration of 1 mL of the samples through 0.45 µm nylon membranes of 13 mm diameter. The fat content is then determined by measuring the absorbance of band at 1745 cm(-1). The proposed method can be used for the direct estimation of fat at concentrations in the 2-12 mg/L interval with adequate reproducibility. The intraday precision, expressed as coefficients of variation CVs, were ≤ 11%, whereas the interday CVs were ≤ 20%. The method shows a good tolerance towards conditions typically found in the effluents generated by the dairy industry. The most relevant features of the proposed method are simplicity and speed as the samples can be characterized in a few minutes. Sample preparation does not involve either additional instrumentation (such as pumps or vacuum equipment) or organic solvents or other chemicals. Therefore, the proposed method can be considered a rapid, simple and cost-effective alternative to gravimetric methods for controlling fat content in these effluents during production or cleaning processes. © 2013 Published by Elsevier B.V.
Multiset canonical correlations analysis and multispectral, truly multitemporal remote sensing data.
Nielsen, Allan Aasbjerg
2002-01-01
This paper describes two- and multiset canonical correlations analysis (CCA) for data fusion, multisource, multiset, or multitemporal exploratory data analysis. These techniques transform multivariate multiset data into new orthogonal variables called canonical variates (CVs) which, when applied in remote sensing, exhibit ever-decreasing similarity (as expressed by correlation measures) over sets consisting of 1) spectral variables at fixed points in time (R-mode analysis), or 2) temporal variables with fixed wavelengths (T-mode analysis). The CVs are invariant to linear and affine transformations of the original variables within sets which means, for example, that the R-mode CVs are insensitive to changes over time in offset and gain in a measuring device. In a case study, CVs are calculated from Landsat Thematic Mapper (TM) data with six spectral bands over six consecutive years. Both Rand T-mode CVs clearly exhibit the desired characteristic: they show maximum similarity for the low-order canonical variates and minimum similarity for the high-order canonical variates. These characteristics are seen both visually and in objective measures. The results from the multiset CCA R- and T-mode analyses are very different. This difference is ascribed to the noise structure in the data. The CCA methods are related to partial least squares (PLS) methods. This paper very briefly describes multiset CCA-based multiset PLS. Also, the CCA methods can be applied as multivariate extensions to empirical orthogonal functions (EOF) techniques. Multiset CCA is well-suited for inclusion in geographical information systems (GIS).
Nassar-Sheikh Rashid, Amara; Taminiau, Jan A; Benninga, Marc A; Saps, Miguel; Tabbers, Merit M
2016-04-01
Functional disorders of the upper gastrointestinal tract are frequently diagnosed in children. Four different clinical entities are addressed by the Rome III committee: functional dyspepsia (FD), cyclic vomiting syndrome (CVS), adolescent rumination syndrome (ARS), and aerophagia. Management of these disorders is often difficult leading to a wide variety in therapeutic interventions. We hypothesize that definitions and outcome measures in these studies are heterogeneous as well. Our aim is to systematically assess how these disorders and outcomes are defined in therapeutic randomized controlled trials (RCTs). CENTRAL, Embase, and MEDLINE/PubMed were searched from inception to February 25, 2015. Search terms were FD, CVS, ARS, and aerophagia. Therapeutic RCTs, or systematic reviews of RCTs, in English language including subjects ages 4 to 18 years (0-18 years for CVS) were evaluated. Quality was assessed using the Delphi list. A total of 1398 articles were found of which 8 articles were included. Seven concerned FD and 1 concerned CVS. In all of the studies, Rome criteria or similar definitions were used; all the studies however used different outcome measures. Seventy-five percent of the trials were of good methodological quality. Only 57% used validated pain scales. Different outcome measures are used in therapeutic trials on functional disorders of the upper gastrointestinal tract. There is a clear paucity of trials evaluating different treatment regimens regarding CVS, ARS, and aerophagia. Uniform definitions, outcome measures, and validated instruments are needed to make a comparison between intervention studies possible.
Yang, Baolin; Cai, Baizhen; Deng, Panyue; Wu, Xiaoqiong; Guan, Yinglu; Zhang, Bin; Cai, Weijun; Schaper, Jutta; Schaper, Wolfgang
2015-01-01
Macrophage invasion is an important event during arteriogenesis, but the underlying mechanism is still only partially understood. The present study tested the hypothesis that nitric oxide (NO) and VE-cadherin, two key mediators for vascular permeability, contribute to this event in a rat ischemic hindlimb model. In addition, the effect of NO on expression of VE-caherin and endothelial permeability was also studied in cultured HUVECs. We found that: 1) in normal arteriolar vessels (NAV), eNOS was moderately expressed in endothelial cells (EC) and iNOS was rarely detected. In contrast, in collateral vessels (CVs) induced by simple femoral artery ligation, both eNOS and iNOS were significantly upregulated (P<0.05). Induced iNOS was found mainly in smooth muscle cells, but also in other vascular cells and macrophages; 2) in NAV VE-cadherin was strongly expressed in EC. In CVs, VE-cadherin was significantly downregulated, with a discontinuous and punctate pattern. Administration of nitric oxide donor DETA NONOate (NONOate) further reduced the amounts of Ve-cadherin in CVs, whereas NO synthase inhibitor L-NAME inhibited downregulation of VE-cadherin in CVs; 3) in normal rats Evans blue extravasation (EBE) was low in the musculus gracilis, FITC-dextron leakage was not detected in the vascular wall and few macrophages were observed in perivascular space. In contrast, EBE was significantly increased in femoral artery ligation rats, FITC-dextron leakage and increased amounts of macrophages were detected in CVs, which were further enhanced by administration of NONOate, but inhibited by L-NAME supplement; 4) in vitro experiments confirmed that an increase in NO production reduced VE-cadherin expression, correlated with increases in the permeability of HUVECs. In conclusion, our data for the first time reveal the expression profile of VE-cadherin and alterations of vascular permeability in CVs, suggesting that NO-mediated VE-cadherin pathway may be one important mechanism responsible, at least in part, for macrophage invasion during arteriogenesis.
Wu, Xiaoqiong; Guan, Yinglu; Zhang, Bin; Cai, Weijun; Schaper, Jutta; Schaper, Wolfgang
2015-01-01
Macrophage invasion is an important event during arteriogenesis, but the underlying mechanism is still only partially understood. The present study tested the hypothesis that nitric oxide (NO) and VE-cadherin, two key mediators for vascular permeability, contribute to this event in a rat ischemic hindlimb model. In addition, the effect of NO on expression of VE-caherin and endothelial permeability was also studied in cultured HUVECs. We found that: 1) in normal arteriolar vessels (NAV), eNOS was moderately expressed in endothelial cells (EC) and iNOS was rarely detected. In contrast, in collateral vessels (CVs) induced by simple femoral artery ligation, both eNOS and iNOS were significantly upregulated (P<0.05). Induced iNOS was found mainly in smooth muscle cells, but also in other vascular cells and macrophages; 2) in NAV VE-cadherin was strongly expressed in EC. In CVs, VE-cadherin was significantly downregulated, with a discontinuous and punctate pattern. Administration of nitric oxide donor DETA NONOate (NONOate) further reduced the amounts of Ve-cadherin in CVs, whereas NO synthase inhibitor L-NAME inhibited downregulation of VE-cadherin in CVs; 3) in normal rats Evans blue extravasation (EBE) was low in the musculus gracilis, FITC-dextron leakage was not detected in the vascular wall and few macrophages were observed in perivascular space. In contrast, EBE was significantly increased in femoral artery ligation rats, FITC-dextron leakage and increased amounts of macrophages were detected in CVs, which were further enhanced by administration of NONOate, but inhibited by L-NAME supplement; 4) in vitro experiments confirmed that an increase in NO production reduced VE-cadherin expression, correlated with increases in the permeability of HUVECs. In conclusion, our data for the first time reveal the expression profile of VE-cadherin and alterations of vascular permeability in CVs, suggesting that NO-mediated VE-cadherin pathway may be one important mechanism responsible, at least in part, for macrophage invasion during arteriogenesis. PMID:26133549
Zhang, Daiting; He, Feilong; Bi, Shuilian; Guo, Huixia; Zhang, Baoshi; Wu, Fan; Liang, Jiaqi; Yang, Youtian; Tian, Qin; Ju, Chunmei; Fan, Huiying; Chen, Jinding; Guo, Xiaofeng; Luo, Yongwen
2016-01-01
Rabies remains a major public health concern in many developing countries. The precise neuropathogenesis of rabies is unknown, though it is hypothesized to be due to neuronal death or dysfunction. Mice that received intranasal inoculation of an attenuated rabies virus (RABV) strain HEP-Flury exhibited subtle clinical signs, and eventually recovered, which is different from the fatal encephalitis caused by the virulent RABV strain CVS-11. To understand the neuropathogenesis of rabies and the mechanisms of viral clearance, we applied RNA sequencing (RNA-Seq) to compare the brain transcriptomes of normal mice vs. HEP-Flury or CVS-11 intranasally inoculated mice. Our results revealed that both RABV strains altered positively and negatively the expression levels of many host genes, including genes associated with innate and adaptive immunity, inflammation and cell death. It is found that HEP-Flury infection can activate the innate immunity earlier through the RIG-I/MDA-5 signaling, and the innate immunity pre-activated by HEP-Flury or Newcastle disease virus (NDV) infection can effectively prevent the CVS-11 to invade central nervous system (CNS), but fails to clear the CVS-11 after its entry into the CNS. In addition, following CVS-11 infection, genes implicated in cell adhesion, blood vessel morphogenesis and coagulation were mainly up-regulated, while the genes involved in synaptic transmission and ion transport were significantly down-regulated. On the other hand, several genes involved in the MHC class II-mediated antigen presentation pathway were activated to a greater extent after the HEP-Flury infection as compared with the CVS-11 infection suggesting that the collaboration of CD4(+) T cells and MHC class II-mediated antigen presentation is critical for the clearance of attenuated RABV from the CNS. The differentially regulated genes reported here are likely to include potential therapeutic targets for expanding the post-exposure treatment window for RABV infection.
Ehlert, Angelika; Schmidt, Christoph; Wölfer, Johannes; Manthei, Gerd; Jacobs, Andreas H; Brüning, Roland; Heindel, Walter; Ringelstein, E Bernd; Stummer, Walter; Pluta, Ryszard M; Hesselmann, Volker
2016-01-01
OBJECT Delayed ischemic neurological deficits (DINDs) and cerebral vasospasm (CVS) are responsible fora poor outcome in patients with aneurysmal subarachnoid hemorrhage (SAH), most likely because of a decreased availability of nitric oxide (NO) in the cerebral microcirculation. In this study, the authors examined the effects of treatment with the NO donor molsidomine with regard to decreasing the incidence of spasm-related delayed brain infarctions and improving clinical outcome in patients with SAH. METHODS Seventy-four patients with spontaneous aneurysmal SAH were included in this post hoc analysis. Twenty-nine patients with SAH and proven CVS received molsidomine in addition to oral or intravenous nimodipine. Control groups consisted of 25 SAH patients with proven vasospasm and 20 SAH patients without. These patients received nimodipine therapy alone. Cranial computed tomography (CCT) before and after treatment was analyzed for CVS-related infarcts. A modified National Institutes of Health Stroke Scale (mNIHSS) and the modified Rankin Scale (mRS) were used to assess outcomes at a 3-month clinical follow-up. RESULTS Four of the 29 (13.8%) patients receiving molsidomine plus nimodipine and 22 of the 45 (48%) patients receiving nimodipine therapy alone developed vasospasm-associated brain infarcts (p < 0.01). Follow-up revealed a median mNIHSS score of 3.0 and a median mRS score of 2.5 in the molsidomine group compared with scores of 11.5 and 5.0, respectively, in the nimodipine group with CVS (p < 0.001). One patient in the molsidomine treatment group died, and 12 patients in the standard care group died (p < 0.01). CONCLUSIONS In this post hoc analysis, patients with CVS who were treated with intravenous molsidomine had a significant improvement in clinical outcome and less cerebral infarction. Molsidomine offers a promising therapeutic option in patients with severe SAH and CVS and should be assessed in a prospective study.
Gebler, J.B.
2004-01-01
The related topics of spatial variability of aquatic invertebrate community metrics, implications of spatial patterns of metric values to distributions of aquatic invertebrate communities, and ramifications of natural variability to the detection of human perturbations were investigated. Four metrics commonly used for stream assessment were computed for 9 stream reaches within a fairly homogeneous, minimally impaired stream segment of the San Pedro River, Arizona. Metric variability was assessed for differing sampling scenarios using simple permutation procedures. Spatial patterns of metric values suggest that aquatic invertebrate communities are patchily distributed on subsegment and segment scales, which causes metric variability. Wide ranges of metric values resulted in wide ranges of metric coefficients of variation (CVs) and minimum detectable differences (MDDs), and both CVs and MDDs often increased as sample size (number of reaches) increased, suggesting that any particular set of sampling reaches could yield misleading estimates of population parameters and effects that can be detected. Mean metric variabilities were substantial, with the result that only fairly large differences in metrics would be declared significant at ?? = 0.05 and ?? = 0.20. The number of reaches required to obtain MDDs of 10% and 20% varied with significance level and power, and differed for different metrics, but were generally large, ranging into tens and hundreds of reaches. Study results suggest that metric values from one or a small number of stream reach(es) may not be adequate to represent a stream segment, depending on effect sizes of interest, and that larger sample sizes are necessary to obtain reasonable estimates of metrics and sample statistics. For bioassessment to progress, spatial variability may need to be investigated in many systems and should be considered when designing studies and interpreting data.
Meroplankton Monitoring Data from a Fixed Platform in the Chesapeake Bay Mouth, 1982-1983.
1984-11-01
the field in 10% formalin in seawater. During .., the sorting process in the laboratory, samples were split as required following the "CVS" method of...8217 -23- [3 =NUSTON 0 -- WACE cJ LLJ to LuJ Lcm *pJ SL O Q_* J FMRA M J JR A5O NO0 1983 Figure 3. Density of Anchoa mitchilli eggs by depth by semimonth
Child Predictors of Learning to Control Variables via Instruction or Self-Discovery
ERIC Educational Resources Information Center
Wagensveld, Barbara; Segers, Eliane; Kleemans, Tijs; Verhoeven, Ludo
2015-01-01
We examined the role child factors on the acquisition and transfer of learning the control of variables strategy (CVS) via instruction or self-discovery. Seventy-six fourth graders and 43 sixth graders were randomly assigned to a group receiving direct CVS instruction or a discovery learning group. Prior to the intervention, cognitive, scientific,…
ERIC Educational Resources Information Center
Schwichow, Martin; Christoph, Simon; Boone, William J.; Härtig, Hendrik
2016-01-01
The so-called control-of-variables strategy (CVS) incorporates the important scientific reasoning skills of designing controlled experiments and interpreting experimental outcomes. As CVS is a prominent component of science standards appropriate assessment instruments are required to measure these scientific reasoning skills and to evaluate the…
Promoting the Social Inclusion of Children with Autism Spectrum Disorders in Community Groups
ERIC Educational Resources Information Center
McConkey, Roy; Mullan, Audrey; Addis, Jackie
2012-01-01
Children with autism spectrum disorders (ASDs) are not easily included in mainstream youth activities provided by the community and voluntary sector (CVS) such as scouts, sports organisations and youth clubs. Two studies were undertaken. First, a survey of over 200 personnel from CVS groups to ascertain their previous experience of these children…
40 CFR 86.1319-90 - CVS calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... with such a device.) The CVS calibration procedures are designed for use of a “metering venturi” type... series with the pump. (ii) The calculated flow rate, ft 3/min, (at pump inlet absolute pressure and... during test period N Revs ±1 Rev. Elapsed time for test period t sec. ±0.5 sec. (5) After the system has...
40 CFR 86.1319-90 - CVS calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
... with such a device.) The CVS calibration procedures are designed for use of a “metering venturi” type... series with the pump. (ii) The calculated flow rate, ft 3/min, (at pump inlet absolute pressure and... test period N Revs ±1 Rev. Elapsed time for test period t sec. ±0.5 sec. (5) After the system has been...
40 CFR 86.1319-90 - CVS calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
... with such a device.) The CVS calibration procedures are designed for use of a “metering venturi” type... series with the pump. (ii) The calculated flow rate, ft 3/min, (at pump inlet absolute pressure and... during test period N Revs ±1 Rev. Elapsed time for test period t sec. ±0.5 sec. (5) After the system has...
40 CFR 86.1319-90 - CVS calibration.
Code of Federal Regulations, 2012 CFR
2012-07-01
... with such a device.) The CVS calibration procedures are designed for use of a “metering venturi” type... series with the pump. (ii) The calculated flow rate, ft 3/min, (at pump inlet absolute pressure and... test period N Revs ±1 Rev. Elapsed time for test period t sec. ±0.5 sec. (5) After the system has been...
USDA-ARS?s Scientific Manuscript database
Pseudomonas syringae pv. tomato DC3000 (Pto) lives epiphytically and endophytically during its infection cycle. Two-component systems (TCSs) and extracytoplasmic function (ECF) sigma factors are used by Pto to sense environmental changes within the leaf apoplast during pathogenesis. The TCS, CvsSR i...
Volatile components from mango (Mangifera indica L.) cultivars.
Pino, Jorge A; Mesa, Judith; Muñoz, Yamilie; Martí, M Pilar; Marbot, Rolando
2005-03-23
The volatile components of 20 mango cultivars were investigated by means of simultaneous distillation-extraction, GC, and GC-MS. Three hundred and seventy-two compounds were identified, of which 180 were found for the first time in mango fruit. The total concentration of volatiles was approximately 18-123 mg/kg of fresh fruit. Terpene hydrocarbons were the major volatiles of all cultivars, the dominant terpenes being delta-3-carene (cvs. Haden, Manga amarilla, Macho, Manga blanca, San Diego, Manzano, Smith, Florida, Keitt, and Kent), limonene (cvs. Delicioso, Super Haden, Ordonez, Filipino, and La Paz), both terpenes (cv. Delicia), terpinolene (cvs. Obispo, Corazon, and Huevo de toro), and alpha-phellandrene (cv. Minin). Other qualitative and quantitative differences among the cultivars could be demonstrated.
Roda, Aldo; Mirasoli, Mara; Venturoli, Simona; Cricca, Monica; Bonvicini, Francesca; Baraldini, Mario; Pasini, Patrizia; Zerbini, Marialuisa; Musiani, Monica
2002-10-01
To allow multianalyte binding assays, we have developed a novel polystyrene microtiter plate containing 24 main wells, each divided into 7 subwells. We explored its clinical potential by developing a PCR-chemiluminescent immunoassay (PCR-CLEIA) for simultaneous detection and typing of seven high oncogenic risk human papillomavirus (HPV) DNAs in one well. Seven different oligonucleotide probes, each specific for a high-risk HPV genotype, were separately immobilized in the subwells. Subsequently, a digoxigenin-labeled consensus PCR amplification product was added to the main well. The PCR product hybridized to the immobilized probe corresponding to its genotype and was subsequently detected by use of a peroxidase-labeled anti-digoxigenin antibody and chemiluminescence imaging with an ultrasensitive charge-coupled device camera. Results obtained for 50 cytologic samples were compared with those obtained with a conventional colorimetric PCR-ELISA. The method was specific and allowed detection of 50 genome copies of HPV 16, 18, 33, and 58, and 100 genome copies of HPV 31, 35, and 45. Intra- and interassay CVs for the method were 5.6% and 7.9%, respectively. All results obtained for clinical samples were confirmed by the conventional PCR-ELISA. PCR-CLEIA allows rapid, single-tube simultaneous detection and typing of seven high-risk HPV DNAs with small reagent volumes. The principle appears applicable to the development of other single-tube panels of tests.
Determinants of parental decisions to abort for chromosome abnormalities.
Drugan, A; Greb, A; Johnson, M P; Krivchenia, E L; Uhlmann, W R; Moghissi, K S; Evans, M I
1990-08-01
Parental decisions concerning the continuation of pregnancy following prenatal detection of abnormal chromosomes were evaluated for 80 patients whose diagnosis and prenatal counselling were performed in our centre. Twenty-two anomalies were diagnosed by chorionic villus sampling (CVS) and 58 by amniocentesis. The severity of the chromosome anomaly and associated ultrasound findings in the first vs. second trimester were correlated with patients' decisions. No difference was found in the likelihood of parental decisions to interrupt or continue a pregnancy between CVS and amniocentesis for either the 'severe' or the 'questionable' group of chromosome anomalies. Ninety-three per cent of patients with severe prognosis and 27 per cent with questionable prognosis opted for pregnancy termination (p less than 0.0001). The association of ultrasound anomalies and termination was highly significant (p less than 0.001). The severity of the chromosome anomaly, and, to a lesser extent, the visualization of anomalies on ultrasound were the major determinants of parental decisions to terminate the pregnancy. The diagnosis of an anomaly in the first trimester was no more likely ito lead to a termination of pregnancy than in the second trimester.
The sample of FBS cataclysmic variables
NASA Astrophysics Data System (ADS)
Mickaelian, Areg M.; Sinamyan, Parandzem K.
2013-02-01
abstract-type="normal"> The First Byurakan Survey (FBS) was conducted by Markarian et al. (1989) to reveal UV-excess galaxies. However, many other interesting objects were possible to detect based on its low-dispersion spectra, and the Second part of the FBS (Mickaelian 2008) was carried out later to reveal UV-excess stellar (point-like) objects, such as white dwarfs (WD), hot subdwarfs, cataclysmic variables (CV), HBB stars, as well as QSOs and Seyfert galaxies. In addition, the FBS plates were digitized (DFBS, Digitized First Byurakan Survey; Mickaelian et al. 2007) and the extraction and reduction of spectra allowed selection of objects with higher confidence and to fainter magnitudes. Spectroscopic observations have been carried out with three telescopes (Byurakan Astrophysical Observatory BAO-2.6m, Russian Special Astrophysical Observatory SAO-6m and Observatoire de Haute Provence OHP-1.93m) (Sinamyan & Mickaelian 2009) for classification of objects. The spectral features of CVs are narrow emission lines (Balmer series, HeI and HeII lines and Bowen band at 4640A) (Fig. 1). In addition, we use the NSVS database (Wozniak et al. 2004) for revealing variability and our method of comparison of POSS1 and POSS2 epoch photometric data (Mickaelian et al. 2011) based on accurate calculations of weighted average POSS1 and POSS2 magnitudes. 27 objects are present in the NSVS and light curves are available (Fig 2.). X-ray data may serve as an additional criterion to detect CVs among the FBS blue stellar objects (Voges et al. 1999; 2000). The subsample of FBS WDs has already been published (Sinamyan & Mickaelian 2011), where some CVs are also present. The subsample of FBS CVs consists of 38 objects, including the following types: dwarf novae (DN; UG and SU subtypes; 7 objects), nova-like variables (NL; SH, AC, VY subtypes; 11 objects), as well as there is a DQ Her type object (FBS 1140+719), a Helium CV (HeCV; FBS 1232+379), and a Low-mass X-ray Binary (LMXB; FBS 1656+354). Other objects do not have accurate classification because of the lack of photometric data. The Periods are in the range of 0.012 to 0.343 days. To make a complete study of these objects possible, multiwavelength (MW) data were retrieved for these 38 objects, including X-ray (ROSAT BSC and FSC), UV (GALEX), optical (APM, MAPS, USNO-B1.0, GSC 2.3.2, SDSS), and IR (2MASS, WISE, IRAS, AKARI) and MW SEDs were built. For CVs, MW SEDs have some disadvantage as their variability does not allow to have their accurate energy distribution. Diagrams with relations between MW data-points and some other physical parameters were also built.
Allsopp, N; Stock, W D
1992-08-01
The interaction of density and mycorrhizal effects on the growth, mineral nutrition and size distribution of seedlings of two perennial members of the Fabaceae was investigated in pot culture. Seedlings of Otholobium hirtum and Aspalathus linearis were grown at densities of 1, 4, 8 and 16 plants per 13-cm pot with or without vesicular-arbuscular (VA) mycorrhizal inoculum for 120 days. Plant mass, relative growth rates, height and leaf number all decreased with increasing plant density. This was ascribed to the decreasing availability of phosphorus per plant as density increased. O. hirtum was highly dependent on mycorrhizas for P uptake but both mycorrhizal and non-mycorrhizal A. linearis seedlings were able to extract soil P with equal ease. Plant size distribution as measured by the coefficient of variation (CV) of shoot mass was greater at higher densities. CVs of mycorrhizal O. hirtum plants were higher than those of non-mycorrhizal plants. CVs of the facultatively mycorrhizal A. linearis were similar for both mycorrhizal and non-mycorrhizal plants. Higher CVs are attributed to resource preemption by larger individuals. Individuals in populations with high CVs will probably survive stress which would result in the extinction of populations with low CVs. Mass of mycorrhizal plants of both species decreased more rapidly with increasing density than did non-mycorrhizal plant mass. It is concluded that the cost of being mycorrhizal increases as plant density increases, while the benefit decreases. The results suggest that mycorrhizas will influence density-dependent population processes of faculative and obligate mycorrhizal species.
Choo, Hui C; Nosaka, Kazunori; Peiffer, Jeremiah J; Ihsan, Mohammed; Yeo, Chow C; Abbiss, Chris R
2017-09-01
This study examined the test-retest reliability of near-infrared spectroscopy (NIRS), laser Doppler flowmetry (LDF) and Doppler ultrasound to assess exercise-induced haemodynamics. Nine men completed two identical trials consisting of 25-min submaximal cycling at first ventilatory threshold followed by repeated 30-s bouts of high-intensity (90% of peak power) cycling in 32.8 ± 0.4°C and 32 ± 5% relative humidity (RH). NIRS (tissue oxygenation index [TOI] and total haemoglobin [tHb]) and LDF (perfusion units [PU]) signals were monitored continuously during exercise, and leg blood flow was assessed by Doppler ultrasound at baseline and after exercise. Cutaneous vascular conductance (CVC; PU/mean arterial pressure (MAP)) was expressed as the percentage change from baseline (%CVC BL ). Coefficients of variation (CVs) as indicators of absolute reliability were 18.7-28.4%, 20.2-33.1%, 42.5-59.8%, 7.8-12.4% and 22.2-30.3% for PU, CVC, %CVC BL , TOI and tHb, respectively. CVs for these variables improved as exercise continued beyond 10 min. CVs for baseline and post-exercise leg blood flow were 17.8% and 10.5%, respectively. CVs for PU, tHb (r 2 = 0.062) and TOI (r 2 = 0.002) were not correlated (P > 0.05). Most variables demonstrated CVs lower than the expected changes (35%) induced by training or heat stress; however, minimum of 10 min exercise is recommended for more reliable measurements.
NASA Astrophysics Data System (ADS)
Schaefer, Bradley E.
2014-06-01
A combination of magnitudes from the Harvard and Sonneberg plates stacks and the AAVSO data base can create very well-sampled light curves with >10,000 magnitudes and covering all of 1890-2014 for roughly a hundred cataclysmic variables (CVs; novae, novalikes, and dwarf novae). Care must be taken to get all these magnitudes into a modern magnitude system. For the archival plates, these are all close to the B magnitude system so that color terms are small, hence, with the use of modern B magnitudes for the comparison stars, these magnitudes can all be placed onto the Johnson B system. For the archival visual observations, the original comparison sequences can always be found, and the magnitudes for the CV and comparisons must be converted from visual to V, so that the reported magnitudes can be fully corrected to Johnson V. The uncertainties from the plates and the visual magnitudes can always be beaten down by daily or yearly averaging to typical real total error bars of ±0.03 mag, and these are always much smaller than the sampling error arising from flickering and greatly smaller than the range of variations. These very-well-sampled >100 year Johnson B & V light curves can be used to test long term evolution models for CVs. With colleagues, I have made light curves for old novae (GK Per from 1890-2014 with 47,000 mags, V603 Aql from 1898-2014 using 22,722 mags, Q Cyg from 1876-2014 with 6400 mags, T CrB from 1855-2014 using 104,000 mags), Z Cam stars (Z Cam from 1923-2014 with 90,000 mags), and dwarf novae (SS Cyg from 1896-2014 with 403,800 mags). The relative accretion rate is given by both the average flux and by the inverse of the average peak-to-peak time for the dwarf novae. By this means, I have measured the changes in the accretion rate for many CVs and how they change on a yearly basis for a century and longer. These observations are directly compared to various CV evolution models. A complex set of agreements and disagreements is found.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-02
... Catcher Vessels Using Trawl Gear in the Central Regulatory Area of the Gulf of Alaska AGENCY: National... (CVs) using trawl gear in the Central Regulatory Area of the Gulf of Alaska (GOA). This action is... apportioned to CVs using trawl gear in the Central Regulatory Area of the GOA. DATES: Effective 1200 hrs...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-20
... Catcher Vessels Using Trawl Gear in the Western Regulatory Area of the Gulf of Alaska AGENCY: National... (CVs) using trawl gear in the Western Regulatory Area of the Gulf of Alaska (GOA). This action is... apportioned to CVs using trawl gear in the Western Regulatory Area of the GOA. DATES: Effective 1200 hours...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-27
... Vessels Using Trawl Gear in the Western Regulatory Area of the Gulf of Alaska AGENCY: National Marine... (CVs) using trawl gear in the Western Regulatory Area of the Gulf of Alaska (GOA). This action is... apportioned to CVs using trawl gear in the Western Regulatory Area of the GOA. DATES: Effective 1200 hrs...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-27
... Catcher Vessels Using Trawl Gear in the Central Regulatory Area of the Gulf of Alaska AGENCY: National... (CVs) using trawl gear in the Central Regulatory Area of the Gulf of Alaska (GOA). This action is... apportioned to CVs using trawl gear in the Central Regulatory Area of the GOA. DATES: Effective 1200 hrs...
USDA-ARS?s Scientific Manuscript database
Recognition of environmental changes and regulation of genes that allow for adaption to those changes is essential for survival of bacteria. Two-component systems (TCSs) allow bacteria to sense and adapt to their environment. We previously identified the TCS CvsSR in the bacterial plant pathogen Pse...
77 FR 62316 - Holiday CVS, L.L.C., d/b/a CVS/Pharmacy Nos. 219 and 5195; Decision and Order
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-12
... described as tangential. See Gov. Pre- Hearing Statement at 18 (ALJ Ex. 14). In addition, in its Pre... eliminated from the factors which a pharmacist must consider, ``the remaining red flags [we]re still... not resolved conclusively prior to the dispensing of the controlled substance.'' ALJ Ex. 28, at 11-12...
ERIC Educational Resources Information Center
Conrad, Kendon J.; Riley, Barth B.; Conrad, Karen M.; Chan, Ya-Fen; Dennis, Michael L.
2010-01-01
In assessing criminality, researchers have used counts of crimes, arrests, and so on, because interval measures were not available. Additionally, crime seriousness varies depending on demographic factors. This study examined the Crime and Violence Scale (CVS) regarding psychometric quality using item response theory (IRT) and invariance of the…
Díaz, A M; Dellepiane, N; Palomo, L F
1989-09-01
Suckling mouse brain (SMB) rabies vaccine is the preparation most widely used in the countries of Latin American and the Caribbean. This vaccine, prepared according to the Fuenzalida and Palacios method, consists of three fixed rabies virus strains (CVS, 51, and 91). However, the World Health Organization recommends that rabies vaccines for human use be prepared using only a single strain of this virus. In order to determine whether any one of the antigens of the SMB vaccine could be eliminated from the preparation, the immunogenic capacity of the standard trivalent SMB vaccine was compared with that of experimental bivalent (CVS-51, CVS-91, and 51-91) and monovalent (CVS, 51, and 91) SMB vaccines. The study was conducted using adult and suckling albino mice provided by the laboratory at the Pan American Zoonoses Center, Buenos Aires, Argentina, and different strains of fixed and street rabies virus. The experimental vaccines were prepared using the Fuenzalida-Palacios method. Potency and cross-immunity tests were conducted. The results showed that the trivalent vaccine was the most effective in protecting the mice against both fixed and street rabies virus infections and also in inducing rapid development of neutralizing antibody at high titers.
Morton, L L; Siegel, L S
1991-02-01
Twenty reading comprehension-disabled (CD) and 20 reading comprehension and word recognition-disabled (CWRD), right-handed male children were matched with 20 normal-achieving age-matched controls and 20 normal-achieving reading level-matched controls and tested for left ear report on dichotic listening tasks using digits and consonant-vowel combinations (CVs). Left ear report for CVs and digits did not correlate for any of the groups. Both reading-disabled groups showed lower left ear report on digits. On CVs the CD group showed a high left ear report but only when there were no priming precursors, such as directions to attend right first and to process digits first. Priming effects interfered with the processing of both digits and CVs. Theoretically, the CWRD group seems to be characterized by a depressed right hemisphere, whereas the CD group may have a more labile right hemisphere, perhaps tending to overengagement for CV tasks but vulnerable to situational precursors in the form of priming effects. Implications extend to (1) subtyping practices in research with the learning-disabled, (2) inferences drawn from studies using different dichotic stimuli, and (3) the neuropsychology of reading disorders.
NASA Astrophysics Data System (ADS)
Sicard, François; Senet, Patrick
2013-06-01
Well-Tempered Metadynamics (WTmetaD) is an efficient method to enhance the reconstruction of the free-energy surface of proteins. WTmetaD guarantees a faster convergence in the long time limit in comparison with the standard metadynamics. It still suffers, however, from the same limitation, i.e., the non-trivial choice of pertinent collective variables (CVs). To circumvent this problem, we couple WTmetaD with a set of CVs generated from a dihedral Principal Component Analysis (dPCA) on the Ramachandran dihedral angles describing the backbone structure of the protein. The dPCA provides a generic method to extract relevant CVs built from internal coordinates, and does not depend on the alignment to an arbitrarily chosen reference structure as usual in Cartesian PCA. We illustrate the robustness of this method in the case of a reference model protein, the small and very diffusive Met-enkephalin pentapeptide. We propose a justification a posteriori of the considered number of CVs necessary to bias the metadynamics simulation in terms of the one-dimensional free-energy profiles associated with Ramachandran dihedral angles along the amino-acid sequence.
Sicard, François; Senet, Patrick
2013-06-21
Well-Tempered Metadynamics (WTmetaD) is an efficient method to enhance the reconstruction of the free-energy surface of proteins. WTmetaD guarantees a faster convergence in the long time limit in comparison with the standard metadynamics. It still suffers, however, from the same limitation, i.e., the non-trivial choice of pertinent collective variables (CVs). To circumvent this problem, we couple WTmetaD with a set of CVs generated from a dihedral Principal Component Analysis (dPCA) on the Ramachandran dihedral angles describing the backbone structure of the protein. The dPCA provides a generic method to extract relevant CVs built from internal coordinates, and does not depend on the alignment to an arbitrarily chosen reference structure as usual in Cartesian PCA. We illustrate the robustness of this method in the case of a reference model protein, the small and very diffusive Met-enkephalin pentapeptide. We propose a justification a posteriori of the considered number of CVs necessary to bias the metadynamics simulation in terms of the one-dimensional free-energy profiles associated with Ramachandran dihedral angles along the amino-acid sequence.
NASA Technical Reports Server (NTRS)
Liu, Yen; Vinokur, Marcel; Wang, Z. J.
2004-01-01
A three-dimensional, high-order, conservative, and efficient discontinuous spectral volume (SV) method for the solutions of Maxwell's equations on unstructured grids is presented. The concept of discontinuous 2nd high-order loca1 representations to achieve conservation and high accuracy is utilized in a manner similar to the Discontinuous Galerkin (DG) method, but instead of using a Galerkin finite-element formulation, the SV method is based on a finite-volume approach to attain a simpler formulation. Conventional unstructured finite-volume methods require data reconstruction based on the least-squares formulation using neighboring cell data. Since each unknown employs a different stencil, one must repeat the least-squares inversion for every cell at each time step, or to store the inversion coefficients. In a high-order, three-dimensional computation, the former would involve impractically large CPU time, while for the latter the memory requirement becomes prohibitive. In the SV method, one starts with a relatively coarse grid of triangles or tetrahedra, called spectral volumes (SVs), and partition each SV into a number of structured subcells, called control volumes (CVs), that support a polynomial expansion of a desired degree of precision. The unknowns are cell averages over CVs. If all the SVs are partitioned in a geometrically similar manner, the reconstruction becomes universal as a weighted sum of unknowns, and only a few universal coefficients need to be stored for the surface integrals over CV faces. Since the solution is discontinuous across the SV boundaries, a Riemann solver is thus necessary to maintain conservation. In the paper, multi-parameter and symmetric SV partitions, up to quartic for triangle and cubic for tetrahedron, are first presented. The corresponding weight coefficients for CV face integrals in terms of CV cell averages for each partition are analytically determined. These discretization formulas are then applied to the integral form of the Maxwell equations. All numerical procedures for outer boundary, material interface, zonal interface, and interior SV face are unified with a single characteristic formulation. The load balancing in a massive parallel computing environment is therefore easier to achieve. A parameter is introduced in the Riemann solver to control the strength of the smoothing term. Important aspects of the data structure and its effects to communication and the optimum use of cache memory are discussed. Results will be presented for plane TE and TM waves incident on a perfectly conducting cylinder for up to fifth order of accuracy, and a plane wave incident on a perfectly conducting sphere for up to fourth order of accuracy. Comparisons are made with exact solutions for these cases.
Erlandsen, Erland J; Randers, Else
2010-07-01
To evaluate the performance of the Roche Diagnostics Tina-quant Cystatin C particle enhanced immuno turbidimetric assay for the measurement of plasma and serum cystatin C, and to establish reference intervals for cystatin C in healthy blood donors. The cystatin C measurements were performed on the Roche Modular Analytics P automated clinical chemistry analyzer. The cystatin C assay was linear in the measuring range 0.40-7.00 mg/L. Within-run CVs < or = 2.0%, between-run CVs < or = 4.2%, and total CVs < or = 5.5% in plasma pools and in commercial cystatin C control materials (range 1.0-4.7 mg/L). Recovery was 99.4-109.3%. No interference was detected from haemoglobin < 0.9 mmol/L, bilirubin < 330 micromol/L and Intralipid < 20 g/L. Measurement of cystatin C in Li-heparin plasma did not differ significantly from cystatin C measured in serum. Forty patient samples run on the Modular Analytics P (y) were compared to the Siemens Cystatin C assay on the BN II (x): y = 0.817x + 0.270, Sy.x = 0.168 (Deming regression). The non-parametric reference interval for cystatin C was calculated to be 0.41-0.91 mg/L in females (n = 86), and 0.43-0.94 mg/L in males (n = 76). The Mann-Whitney U test showed a significant difference between the two genders (p = 0.015), but the difference was without clinical relevance. A common reference interval for both genders (n = 162) was calculated to be 0.41-0.92 mg/L. The performance of the Tina-quant Cystatin C assay was acceptable for clinical use.
Are former late-preterm children at risk for child vulnerability and overprotection?
Samra, Haifa A; McGrath, Jacqueline M; Wey, Howard
2010-09-01
Parent perception of child vulnerability (PPCV) and parent overprotection (POP) are believed to have serious implications for age appropriate cognitive and psychosocial development in very low birth weight preterm children. With recent concerns about suboptimal developmental outcomes in late-preterm children, this study was aimed at examining the relationship between history of late-preterm birth (34-36 6/7 weeks gestation), and PPCV, POP, and healthcare utilization (HCU). This was a cross-sectional observational design. Study participants were mothers of 54 healthy singleton children recruited from community centers including Women and Children Clinics (WIC), primary care clinics and daycare centers in the upper Midwest region. Outcome measures included Forsyth Child Vulnerability Scale (CVS), Thomasgard Parent Protection Scale (PPS) scores, and healthcare utilization (HCU). Potential covariates included history of life-threatening illness, child and maternal demographics, and maternal stress and depression using the Center for Epidemiologic Studies Depression Scale (CESD). HCU (p=0.02) and the PPS subscales of supervision (p=0.003) and separation (p=0.03) were significant predictors of PPCV in mothers of 3-8 years old children with late-preterm history. Age of the child (p=0.008) and CVS scores (p=0.005) were significant predictors of POP. Maternal age (p=0.04), stress (p=0.04), and CVS scores (p=0.003) were significant predictors of HCU. Dependence, a subscale of the PPS, correlated with the child's age and gender even after controlling for age. History of late-preterm did not predict MPCV, MOP, or HCU in healthy children. Future research is needed in larger more diverse samples to better understand causal relationships and develop strategies to lessen risks of MPCV and MOP. Published by Elsevier Ireland Ltd.
Syvertsen, Jennifer L; Robertson, Angela M; Abramovitz, Daniela; Rangel, M Gudelia; Martinez, Gustavo; Patterson, Thomas L; Ulibarri, Monica D; Vera, Alicia; El-Bassel, Nabila; Strathdee, Steffanie A
2012-02-20
Researchers are increasingly recognizing the importance of addressing sexual and drug-related HIV risk within the context of intimate relationships rather than solely focusing on individual behaviors. Practical and effective methods are needed to recruit, screen, and enroll the high risk and hard-to-reach couples who would most benefit from HIV interventions, such as drug-using female sex workers (FSWs) and their intimate, non-commercial partners. This paper outlines a bi-national, multidisciplinary effort to develop and implement a study protocol for research on the social context and epidemiology of HIV, sexually transmitted infections (STI), and high risk behaviors among FSWs and their non-commercial male partners in Tijuana and Ciudad Juarez, Mexico. We provide an overview of our study and specifically focus on the sampling, recruitment, screening, and successful enrollment of high risk couples into a public health study in this context. We used targeted and snowball sampling to recruit couples through the female partner first and administered a primary screener to check her initial eligibility. Willing and eligible females then invited their primary male partners for couple-based screening using a couple verification screening (CVS) instrument adapted from previous studies. The CVS rechecked eligibility and separately asked each partner the same questions about their relationship to "test" if the couple was legitimate. We adapted the original protocol to consider issues of gender and power within the local cultural and socioeconomic context and expanded the question pool to create multiple versions of the CVS that were randomly administered to potential couples to determine eligibility and facilitate study enrollment. The protocol successfully enrolled 214 high risk couples into a multi-site public health study. This work suggests the importance of collaborating to construct a study protocol, understanding the local population and context, and drawing on multiple sources of input to determine eligibility and verify the legitimacy of relationships. We provide a practical set of tools that other researchers should find helpful in the study of high risk couples in international settings, with particular relevance to studies of FSWs and their intimate partners.
2012-01-01
Background Researchers are increasingly recognizing the importance of addressing sexual and drug-related HIV risk within the context of intimate relationships rather than solely focusing on individual behaviors. Practical and effective methods are needed to recruit, screen, and enroll the high risk and hard-to-reach couples who would most benefit from HIV interventions, such as drug-using female sex workers (FSWs) and their intimate, non-commercial partners. This paper outlines a bi-national, multidisciplinary effort to develop and implement a study protocol for research on the social context and epidemiology of HIV, sexually transmitted infections (STI), and high risk behaviors among FSWs and their non-commercial male partners in Tijuana and Ciudad Juarez, Mexico. We provide an overview of our study and specifically focus on the sampling, recruitment, screening, and successful enrollment of high risk couples into a public health study in this context. Methods/Design We used targeted and snowball sampling to recruit couples through the female partner first and administered a primary screener to check her initial eligibility. Willing and eligible females then invited their primary male partners for couple-based screening using a couple verification screening (CVS) instrument adapted from previous studies. The CVS rechecked eligibility and separately asked each partner the same questions about their relationship to "test" if the couple was legitimate. We adapted the original protocol to consider issues of gender and power within the local cultural and socioeconomic context and expanded the question pool to create multiple versions of the CVS that were randomly administered to potential couples to determine eligibility and facilitate study enrollment. Discussion The protocol successfully enrolled 214 high risk couples into a multi-site public health study. This work suggests the importance of collaborating to construct a study protocol, understanding the local population and context, and drawing on multiple sources of input to determine eligibility and verify the legitimacy of relationships. We provide a practical set of tools that other researchers should find helpful in the study of high risk couples in international settings, with particular relevance to studies of FSWs and their intimate partners. PMID:22348625
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-25
... Catcher Vessels Greater Than or Equal to 50 Feet (15.2 Meters) Length Overall Using Hook-and-Line Gear in...: NMFS is prohibiting directed fishing for Pacific cod by catcher vessels (CVs) greater than or equal to... of the 2013 Pacific cod total allowable catch apportioned to CVs greater than or equal to 50 feet (15...
ERIC Educational Resources Information Center
Matlen, Bryan J.; Klahr, David
2013-01-01
We report the effect of different sequences of high vs low levels of instructional guidance on children's immediate learning and long-term transfer of simple experimental design procedures and concepts, often called "CVS" (Control of Variables Strategy). Third-grade children (N = 57) received instruction in CVS via one of four possible orderings…
40 CFR 1065.341 - CVS, PFD, and batch sampler verification (propane check).
Code of Federal Regulations, 2014 CFR
2014-07-01
... may use the HC contamination procedure in § 1065.520(f) to verify HC contamination. Otherwise, zero... range that can measure the C3H8 concentration expected for the CVS and C3H8 flow rates. (2) Zero the HC analyzer using zero air introduced at the analyzer port. (3) Span the HC analyzer using C3H8 span gas...
40 CFR 1065.341 - CVS and batch sampler verification (propane check).
Code of Federal Regulations, 2012 CFR
2012-07-01
... may use the HC contamination procedure in § 1065.520(g) to verify HC contamination. Otherwise, zero... range that can measure the C3H8 concentration expected for the CVS and C3H8 flow rates. (2) Zero the HC analyzer using zero air introduced at the analyzer port. (3) Span the HC analyzer using C3H8 span gas...
40 CFR 1065.341 - CVS and batch sampler verification (propane check).
Code of Federal Regulations, 2013 CFR
2013-07-01
... may use the HC contamination procedure in § 1065.520(g) to verify HC contamination. Otherwise, zero... range that can measure the C3H8 concentration expected for the CVS and C3H8 flow rates. (2) Zero the HC analyzer using zero air introduced at the analyzer port. (3) Span the HC analyzer using C3H8 span gas...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-12
...., at 1, they invoke the standard from Critical Mass Energy Project v. NRC, 975 F.2d 871 (D.C. Cir. 1992... Mass standard, Respondents are not entitled to the redactions. Moreover, Respondents offer absolutely... explains what legal standard was applied by the Agency in making the determination to continue to protect...
Fischer, B M; Aznar, M C; Hansen, A E; Vogelius, I R; Löfgren, J; Andersen, F L; Loft, A; Kjaer, A; Højgaard, L; Specht, L
2015-01-01
Objective: To investigate reproducibility of fluorine-18 fludeoxyglucose (18F-FDG) uptake on 18F-FDG positron emission tomography (PET)/CT and 18F-FDG PET/MR scans in patients with head and neck squamous cell carcinoma (HNSCC). Methods: 30 patients with HNSCC were included in this prospective study. The patients were scanned twice before radiotherapy treatment with both PET/CT and PET/MR. Patients were scanned on the same scanners, 3 days apart and according to the same protocol. Metabolic tumour activity was measured by the maximum and peak standardized uptake value (SUVmax and SUVpeak, respectively), and total lesion glycolysis from the metabolic tumour volume defined from ≥50% SUVmax. Bland–Altman analysis with limits of agreement, coefficient of variation (CV) from the two modalities were performed in order to test the reproducibility. Furthermore, CVs from SUVmax and SUVpeak were compared. The area under the curve from cumulative SUV–volume histograms were measured and tested for reproducibility of the distribution of 18F-FDG uptake. Results: 24 patients had two pre-treatment PET/CT scans and 21 patients had two pre-treatment PET/MR scans available for further analyses. Mean difference for SUVmax, peak and mean was approximately 4% for PET/CT and 3% for PET/MR, with 95% limits of agreement less than ±20%. CV was small (5–7%) for both modalities. There was no significant difference in CVs between PET/CT and PET/MR (p = 0.31). SUVmax was not more reproducible than SUVpeak (p = 0.09). Conclusion: 18F-FDG uptake in PET/CT and PET/MR is highly reproducible and we found no difference in reproducibility between PET/CT and PET/MR. Advances in knowledge: This is the first report to test reproducibility of PET/CT and PET/MR. PMID:25634069
Factors leading to the computer vision syndrome: an issue at the contemporary workplace.
Izquierdo, Juan C; García, Maribel; Buxó, Carmen; Izquierdo, Natalio J
2007-01-01
Vision and eye related problems are common among computer users, and have been collectively called the Computer Vision Syndrome (CVS). An observational study in order to identify the risk factors leading to the CVS was done. Twenty-eight participants answered a validated questionnaire, and had their workstations examined. The questionnaire evaluated personal, environmental, ergonomic factors, and physiologic response of computer users. The distance from the eye to the computers' monitor (A), the computers' monitor height (B), and visual axis height (C) were measured. The difference between B and C was calculated and labeled as D. Angles of gaze to the computer monitor were calculated using the formula: angle=tan-1(D/A). Angles were divided into two groups: participants with angles of gaze ranging from 0 degree to 13.9 degrees were included in Group 1; and participants gazing at angles larger than 14 degrees were included in Group 2. Statistical analysis of the evaluated variables was made. Computer users in both groups used more tear supplements (as part of the syndrome) than expected. This association was statistically significant (p < 0.10). Participants in Group 1 reported more pain than participants in Group 2. Associations between the CVS and other personal or ergonomic variables were not statistically significant. Our findings show that the most important factor leading to the syndrome is the angle of gaze at the computer monitor. Pain in computer users is diminished when gazing downwards at angles of 14 degrees or more. The CVS remains an under estimated and poorly understood issue at the workplace. The general public, health professionals, the government, and private industries need to be educated about the CVS.
Factors leading to the Computer Vision Syndrome: an issue at the contemporary workplace.
Izquierdo, Juan C; García, Maribel; Buxó, Carmen; Izquierdo, Natalio J
2004-01-01
Vision and eye related problems are common among computer users, and have been collectively called the Computer Vision Syndrome (CVS). An observational study in order to identify the risk factors leading to the CVS was done. Twenty-eight participants answered a validated questionnaire, and had their workstations examined. The questionnaire evaluated personal, environmental, ergonomic factors, and physiologic response of computer users. The distance from the eye to the computers' monitor (A), the computers' monitor height (B), and visual axis height (C) were measured. The difference between B and C was calculated and labeled as D. Angles of gaze to the computer monitor were calculated using the formula: angle=tan(-1)(D/ A). Angles were divided into two groups: participants with angles of gaze ranging from 0 degrees to 13.9 degrees were included in Group 1; and participants gazing at angles larger than 14 degrees were included in Group 2. Statistical analysis of the evaluated variables was made. Computer users in both groups used more tear supplements (as part of the syndrome) than expected. This association was statistically significant (p<0.10). Participants in Group 1 reported more pain than participants in Group 2. Associations between the CVS and other personal or ergonomic variables were not statistically significant. Our findings show that most important factor leading to the syndrome is the angle of gaze at the computer monitor. Pain in computer users is diminished when gazing downwards at angles of 14 degrees or more. The CVS remains an under estimated and poorly understood issue at the workplace. The general public, health professionals, the government, and private industries need to be educated about the CVS.
Schmeltzer, Sarah N; Vollmer, Lauren L; Rush, Jennifer E; Weinert, Mychal; Dolgas, Charles M; Sah, Renu
2015-01-01
Chronicity of trauma exposure plays an important role in the pathophysiology of posttraumatic stress disorder (PTSD). Thus, exposure to multiple traumas on a chronic scale leads to worse outcomes than acute events. The rationale for the current study was to investigate the effects of a single adverse event versus the same event on a background of chronic stress. We hypothesized that a history of chronic stress would lead to worse behavioral outcomes than a single event alone. Male rats (n = 14/group) were exposed to either a single traumatic event in the form of electric foot shocks (acute shock, AS), or to footshocks on a background of chronic stress (chronic variable stress-shock, CVS-S). PTSD-relevant behaviors (fear memory and acoustic startle responses) were measured following 7 d recovery. In line with our hypothesis, CVS-S elicited significant increases in fear acquisition and conditioning versus the AS group. Unexpectedly, CVS-S elicited reduced startle reactivity to an acoustic stimulus in comparison with the AS group. Significant increase in FosB/ΔFosB-like immunostaining was observed in the dentate gyrus, basolateral amygdala and medial prefrontal cortex of CVS-S rats. Assessments of neuropeptide Y (NPY), a stress-regulatory transmitter associated with chronic PTSD, revealed selective reduction in the hippocampus of CVS-S rats. Collectively, our data show that cumulative stress potentiates delayed fear memory and impacts defensive responding. Altered neuronal activation in forebrain limbic regions and reduced NPY may contribute to these phenomena. Our preclinical studies support clinical findings reporting worse PTSD outcomes stemming from cumulative traumatization in contrast to acute trauma.
A Deep X-ray Survey of the Globular Cluster Omega Centauri
NASA Astrophysics Data System (ADS)
Henleywillis, Simon; Cool, Adrienne M.; Haggard, Daryl; Heinke, Craig; Callanan, Paul; Zhao, Yue
2018-03-01
We identify 233 X-ray sources, of which 95 are new, in a 222 ks exposure of Omega Centauri with the Chandra X-ray Observatory's ACIS-I detector. The limiting unabsorbed flux in the core is fX(0.5-6.0 keV) ≃ 3×10-16 erg s-1 cm-2 (Lx ≃ 1×1030 erg s-1 at 5.2 kpc). We estimate that ˜60 ± 20 of these are cluster members, of which ˜30 lie within the core (rc = 155 arcsec), and another ˜30 between 1-2 core radii. We identify four new optical counterparts, for a total of 45 likely identifications. Probable cluster members include 18 cataclysmic variables (CVs) and CV candidates, one quiescent low-mass X-ray binary, four variable stars, and five stars that are either associated with ω Cen's anomalous red giant branch, or are sub-subgiants. We estimate that the cluster contains 40 ± 10 CVs with Lx > 1031 erg s-1, confirming that CVs are underabundant in ω Cen relative to the field. Intrinsic absorption is required to fit X-ray spectra of six of the nine brightest CVs, suggesting magnetic CVs, or high-inclination systems. Though no radio millisecond pulsars (MSPs) are currently known in ω Cen, more than 30 unidentified sources have luminosities and X-ray colours like those of MSPs found in other globular clusters; these could be responsible for the Fermi-detected gamma-ray emission from the cluster. Finally, we identify a CH star as the counterpart to the second-brightest X-ray source in the cluster and argue that it is a symbiotic star. This is the first such giant/white dwarf binary to be identified in a globular cluster.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Craciunescu, Oana I., E-mail: oana.craciunescu@duke.edu; Yoo, David S.; Cleland, Esi
2012-03-01
Purpose: Dynamic contrast-enhanced (DCE) MRI-extracted parameters measure tumor microvascular physiology and are usually calculated from an intratumor region of interest (ROI). Optimal ROI delineation is not established. The valid clinical use of DCE-MRI requires that the variation for any given parameter measured within a tumor be less than that observed between tumors in different patients. This work evaluates the impact of tumor ROI selection on the assessment of intra- and interpatient variability. Method and Materials: Head and neck cancer patients received initial targeted therapy (TT) treatment with erlotinib and/or bevacizumab, followed by radiotherapy and concurrent cisplatin with synchronous TT. DCE-MRImore » data from Baseline and the end of the TT regimen (Lead-In) were analyzed to generate the vascular transfer function (K{sup trans}), the extracellular volume fraction (v{sub e}), and the initial area under the concentration time curve (iAUC{sub 1min}). Four ROI sampling strategies were used: whole tumor or lymph node (Whole), the slice containing the most enhancing voxels (SliceMax), three slices centered in SliceMax (Partial), and the 5% most enhancing contiguous voxels within SliceMax (95Max). The average coefficient of variation (aCV) was calculated to establish intrapatient variability among ROI sets and interpatient variability for each ROI type. The average ratio between each intrapatient CV and the interpatient CV was calculated (aRCV). Results: Baseline primary/nodes aRCVs for different ROIs not including 95Max were, for all three MR parameters, in the range of 0.14-0.24, with Lead-In values between 0.09 and 0.2, meaning a low intrapatient vs. interpatient variation. For 95Max, intrapatient CVs approximated interpatient CVs, meaning similar data dispersion and higher aRCVs (0.6-1.27 for baseline) and 0.54-0.95 for Lead-In. Conclusion: Distinction between different patient's primary tumors and/or nodes cannot be made using 95Max ROIs. The other three strategies are viable and equivalent for using DCE-MRI to measure head and neck cancer physiology.« less
Cheah, Hoay Yan; Kiew, Lik Voon; Lee, Hong Boon; Japundžić-Žigon, Nina; Vicent, Marίa J; Hoe, See Ziau; Chung, Lip Yong
2017-11-01
While nano-sized construct (NSC) use in medicine has grown significantly in recent years, reported unwanted side effects have raised safety concerns. However, the toxicity of NSCs to the cardiovascular system (CVS) and the relative merits of the associated evaluation methods have not been thoroughly studied. This review discusses the toxicological profiles of selected NSCs and provides an overview of the assessment methods, including in silico, in vitro, ex vivo and in vivo models and how they are related to CVS toxicity. We conclude the review by outlining the merits of telemetry coupled with spectral analysis, baroreceptor reflex sensitivity analysis and echocardiography as an appropriate integrated strategy for the assessment of the acute and chronic impact of NSCs on the CVS. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Vinke, Elisabeth J; Eyding, Jens; de Korte, Chris L; Slump, Cornelis H; van der Hoeven, Johannes G; Hoedemaekers, Cornelia W E
2017-12-01
Ultrasound perfusion imaging (UPI) can be used for the quantification of cerebral perfusion. In a neuro-intensive care setting, repeated measurements are required to evaluate changes in cerebral perfusion and monitor therapy. The aim of this study was to determine the repeatability of UPI in quantification of cerebral perfusion. UPI measurement of cerebral perfusion was performed three times in healthy patients. The coefficients of variation of the three bolus injections were calculated for both time- and volume-derived perfusion parameters in the macro- and microcirculation. The UPI time-dependent parameters had overall the lowest CVs in both the macro- and microcirculation. The volume-related parameters had poorer repeatability, especially in the microcirculation. Both intra-observer variability and inter-observer variability were low. Although UPI is a promising tool for the bedside measurement of cerebral perfusion, improvement of the technique is required before implementation in routine clinical practice. Copyright © 2017 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-25
... Catcher Vessels Less Than 50 Feet (15.2 Meters) Length Overall Using Hook-and-Line Gear in the Central... directed fishing for Pacific cod by catcher vessels (CVs) less than 50 feet (15.2 meters (m)) in length... catch apportioned to CVs less than 50 feet (15.2 m) LOA using hook-and-line gear in the Central...
Computer vision syndrome: a review of ocular causes and potential treatments.
Rosenfield, Mark
2011-09-01
Computer vision syndrome (CVS) is the combination of eye and vision problems associated with the use of computers. In modern western society the use of computers for both vocational and avocational activities is almost universal. However, CVS may have a significant impact not only on visual comfort but also occupational productivity since between 64% and 90% of computer users experience visual symptoms which may include eyestrain, headaches, ocular discomfort, dry eye, diplopia and blurred vision either at near or when looking into the distance after prolonged computer use. This paper reviews the principal ocular causes for this condition, namely oculomotor anomalies and dry eye. Accommodation and vergence responses to electronic screens appear to be similar to those found when viewing printed materials, whereas the prevalence of dry eye symptoms is greater during computer operation. The latter is probably due to a decrease in blink rate and blink amplitude, as well as increased corneal exposure resulting from the monitor frequently being positioned in primary gaze. However, the efficacy of proposed treatments to reduce symptoms of CVS is unproven. A better understanding of the physiology underlying CVS is critical to allow more accurate diagnosis and treatment. This will enable practitioners to optimize visual comfort and efficiency during computer operation. Ophthalmic & Physiological Optics © 2011 The College of Optometrists.
Predominate HIV1-specific IgG activity in various mucosal compartments of HIV1-infected individuals.
Lü, F X
2000-10-01
Evaluating mucosal humoral immunity is important for understanding local immunity induced by HIV infection or vaccination and designing prophylactic strategies. To characterize the mucosal humoral immunity following HIV infection, the levels of immunoglobulins (Igs), antibodies (Abs), and HIV1-specific Ab activity were evaluated in cervicovaginal secretions (CVS), saliva, breast milk, and sera of HIV-infected individuals. HIV1-specific IgG activity was significantly higher than that of IgA in CVS, saliva, and breast milk. The highest HIV1-specific IgG activity was found in breast milk. The data suggest that anti-HIV1 Abs in CVS were most likely serum derived. However, HIV1-specific Abs in saliva and breast milk were mainly locally produced. The prevalence of HIV1-specific Abs in seropositive subjects was 97% for IgG and 95% for IgA in CVS, 100% for IgG and 80% for IgA in saliva, and 59% for IgG and 94% for IgA in breast milk. These data provide evidence for both a better understanding of the nature of humoral mucosal responses after HIV1 infection and the development of strategies to induce desirable functional mucosal immunity for preventing HIV transmission. Copyright 2000 Academic Press.
Kotoda, Atsushi; Akimoto, Tetsu; Kato, Maki; Kanazawa, Hidenori; Nakata, Manabu; Sugase, Taro; Ogura, Manabu; Ito, Chiharu; Sugimoto, Hideharu; Muto, Shigeaki; Kusano, Eiji
2011-01-01
It is widely assumed that central venous stenosis (CVS) is most commonly associated with previous central venous catheterization among the chronic hemodialysis (HD) patients. We evaluated the validity of this assumption in this retrospective study. The clinical records from 2,856 consecutive HD patients with vascular access failure during a 5-year period were reviewed, and a total of 26 patients with symptomatic CVS were identified. Combined with radiological findings, their clinical characteristics were examined. Only seven patients had a history of internal jugular dialysis catheterization. Diagnostic multidetector row computed tomography angiography showed that 7 of the 19 patients with no history of catheterization had left innominate vein stenosis due to extrinsic compression between the sternum and arch vessels. These patients had a shorter period from the time of creation of the vascular access to the initial referral (9.2 ± 7.6 months) than the rest of the patients (35.5 ± 18.6 months, p = 0.0017). Our findings suggest that cases without a history of central venous catheterization may not be rare among the HD patients with symptomatic CVS. However, those still need to be confirm by larger prospective studies of overall chronic HD patients with symptomatic CVS.
NASA Astrophysics Data System (ADS)
Pradon, A.; Caldes, M. T.; Petit, P.-E.; La Fontaine, C.; Elkaim, E.; Tessier, C.; Ouvrard, G.; Dumont, E.
2018-03-01
A Li-rich lamellar oxide was cycled at high potential and the relevance of using a constant voltage step (CVS) at the end of the charge, needed for industrial application, was investigated by electrochemical performance, X-ray diffraction (XRD) and high resolution transmission electron microscopy (HRTEM). Electrochemical studies at 4.7 and 4.5 V with and without CVS showed that capacity and voltage fading occurred mostly when cells operated at high potential. After cycling, 3D-type defects involving transition metals trapped in lithium layer were observed by HRTEM into the electrode bulk. These defects are responsible for the voltage fading. XRD microstrain parameter was used to evaluate defects rate in aged materials subjected to a CVS, showing more 3D-type defects when cycled at 4.7 V than at 4.5 V. The time spent at high potential at the end of the charge as well as the value of the upper potential limit, are both relevant parameters to voltage decay. The use of a CVS at the end of the charge needs at the same time, a reduced upper potential window in order to minimize 3D-type defects occurrence. Unfortunately, this approach is still not sufficient to prevent voltage fading.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-07
.... 101126522-0640-2] RIN 0648-XB062 Pacific Cod by Catcher Vessels Less Than 50 Feet (15.2 Meters) Length... (CVs) less than 50 feet (15.2 meters (m)) in length overall (LOA) using hook-and-line gear in the... season allowance of the 2012 Pacific cod total allowable catch apportioned to CVs less than 50 feet (15.2...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-23
.... 111207737-2141-02] RIN 0648-XB112 Pacific Cod by Catcher Vessels Greater Than or Equal to 50 Feet (15.2... catcher vessels (CVs) greater than or equal to 50 feet (15.2 meters (m)) in length overall (LOA) using... to CVs greater than or equal to 50 feet (15.2 m) LOA using hook-and-line gear in the Central...
Comparison of steady-state and transient CVS cycle emission of an automotive Stirling engine
NASA Technical Reports Server (NTRS)
Farrell, R. A.; Bolton, R. J.
1983-01-01
The Automotive Stirling Engine Development Program is to demonstrate a number of goals for a Stirling-powered vehicle. These goals are related to an achievement of specified maximum emission rates, a combined cycle fuel economy 30 percent better than a comparable internal-combustion engine-powered automobile, multifuel capability, competitive cost and reliability, and a meeting of Federal standards concerning noise and safety. The present investigation is concerned with efforts related to meeting the stringent emission goals. Attention is given to the initial development of a procedure for predicting transient CVS urban cycle gaseous emissions from steady-state engine data, taking into account the employment of the test data from the first-generation automotive Stirling engine. A large amount of steady-state data from three Mod I automotive Stirling engines were used to predict urban CVS cycle emissions for the Mod I Lerma vehicle.
VizieR Online Data Catalog: Dwarf novae outbursts properties (Otulakowska-Hypka+, 2016)
NASA Astrophysics Data System (ADS)
Otulakowska-Hypka, M.; Olech, A.; Patterson, J.
2017-11-01
In this study, we used the following available catalogue data sources. The catalogue and atlas of CVs (https://archive.stsci.edu/prepds/cvcat/) by Downes et al. (2001PASP..113..764D, Cat. V/123) which contains 1830 objects that have been classified as a CV before 2006 February 1, when the catalogue was frozen. Catalogue of cataclysmic binaries, low-mass X-ray binaries and related objects (http://www.mpa-garching.mpg.de/RKcat/) by Ritter & Kolb (2003A&A...404..301R, Cat. B/cb). Although the reference corresponds to a catalogue which is over 10yr old, its newest edition 7.21 (2013 December 31) has been used in this study. This catalogue contains 1094 CVs. Catalogue of J. Patterson, that is the supplementary electronic material to the publication Patterson (2011) containing properties of 292 non-magnetic CVs with orbital periods smaller than 3h (http://cbastro.org/dwarfnovashort/) (1 data file).
Monteiro, João Filipe G.; Marshall, Brandon D.L.; Escudero, Daniel; Sosa-Rubí, Sandra G.; González, Andrea; Flanigan, Timothy; Operario, Don; Mayer, Kenneth H.; Lurie, Mark N.; Galárraga, Omar
2015-01-01
Mexico has a concentrated HIV epidemic, with male sex workers constituting a key affected population. We estimated annual HIV cumulative incidence among male sex workers’ partners, and then compared incidence under three hypothetical intervention scenarios: improving condom use; and scaling up HIV treatment as prevention, considering current viral suppression rates (CVS, 60.7%) or full viral suppression among those treated (FVS, 100%). Clinical and behavioral data to inform model parameterization were derived from a sample (n=79) of male sex workers recruited from street locations and Clínica Condesa, an HIV clinic in Mexico City. We estimated annual HIV incidence among male sex workers’ partners to be 8.0% (95% CI: 7.3–8.7). Simulation models demonstrated that increasing condom use by 10%, and scaling up HIV treatment initiation by 50% (from baseline values) would decrease the male sex workers-attributable annual incidence to 5.2%, 4.4% (CVS) and 3.2% (FVS), respectively. Scaling up the number of male sex workers on ART and implementing interventions to ensure adherence is urgently required to decrease HIV incidence among male sex workers’ partners in Mexico City. PMID:25307025
Monteiro, João Filipe G; Marshall, Brandon D L; Escudero, Daniel; Sosa-Rubí, Sandra G; González, Andrea; Flanigan, Timothy; Operario, Don; Mayer, Kenneth H; Lurie, Mark N; Galárraga, Omar
2015-09-01
Mexico has a concentrated HIV epidemic, with male sex workers constituting a key affected population. We estimated annual HIV cumulative incidence among male sex workers' partners, and then compared incidence under three hypothetical intervention scenarios: improving condom use; and scaling up HIV treatment as prevention, considering current viral suppression rates (CVS, 60.7 %) or full viral suppression among those treated (FVS, 100 %). Clinical and behavioral data to inform model parameterization were derived from a sample (n = 79) of male sex workers recruited from street locations and Clínica Condesa, an HIV clinic in Mexico City. We estimated annual HIV incidence among male sex workers' partners to be 8.0 % (95 % CI: 7.3-8.7). Simulation models demonstrated that increasing condom use by 10 %, and scaling up HIV treatment initiation by 50 % (from baseline values) would decrease the male sex workers-attributable annual incidence to 5.2, 4.4 % (CVS) and 3.2 % (FVS), respectively. Scaling up the number of male sex workers on ART and implementing interventions to ensure adherence is urgently required to decrease HIV incidence among male sex workers' partners in Mexico City.
[Characterisation of viral agents with potential to cause diarrhea in Djibouti].
Maslin, J; Kohli, E; Leveque, N; Chomel, J J; Nicand, E; Fouet, C; Haus, R; Depina, J J; Mathecowitsch, P; Dampierre, H
2007-06-01
Due to limited laboratory facilities in the tropics, the exact role of enteric viruses in causing diarrhea among adults in the tropics is unknown. The purpose of this report is to describe a multicenter study undertaken in Djibouti to determine the prevalence of a large panel of enteric viruses using immunochromatography; antigenic detection by ELISA, RT-PCR cellular inoculation, sequence analysis; and indirect serology. Study samples were collected from 108 patients presenting acute and sporadic diarrhea. Although they are well known causes of diarrhea in children, rotavirus and adenovirus were identified in only 2 and 5% of adults respectively. In contrast human caliciviruses (HuCVs) and enterovirus were identified in 25 and 42% of adult cases respectively. Uncommon genotypes of HuCVs and recombinant forms (junction pol/l cap) as well as a significant number of sapovirus (30%) were identified. Further study is needed to clarify the role of enterovirus (echovirus) in the etiology of acute diarrhea in adults. No polivirus was identified. These new data from the Horn of Africa increase our knowledge about the epidemiology of acute infectious diarrhea that is a major public health problem and potential danger for travelers.
Quality of Human Immunodeficiency Virus Viral Load Testing in Australia
Best, Susan J.; Gust, Anthony P.; Johnson, Elizabeth I. M.; McGavin, Catherine H.; Dax, Elizabeth M.
2000-01-01
This study determined the proficiencies of laboratories measuring human immunodeficiency virus type 1 (HIV-1) viral loads and the accuracies of two assays used for HIV-1 viral load measurement in Australia and investigated the variability of the new versions of these assays. Quality assessment program panels containing (i) dilutions of HIV-1 subtype B, (ii) replicates of identical samples of HIV-1 subtype B, and (iii) samples of subtype E and B were tested by laboratories. Total variability (within and between laboratories) was tested with quality control samples. The coefficients of variation (CVs) for the Roche AMPLICOR HIV-1 MONITOR version (v) 1.0 and Chiron Quantiplex bDNA 2.0 assays ranged from 53 to 87% and 22 to 31%, respectively. The widespread occurrence of invalid runs with the AMPLICOR HIV-1 MONITOR 1.0 assay was identified. The CVs of the new versions of the assays were 82 to 86% for the AMPLICOR HIV-1 MONITOR v 1.5 assay and 16 to 23% for the Quantiplex bDNA 3.0 assay. For virus dilution samples, all but 5 of 19 laboratories obtained results within 2 standard deviations of the mean. The Quantiplex bDNA 2.0 assay reported values lower than those reported by the AMPLICOR HIV-1 MONITOR version 1.0 assay for samples containing HIV-1 subtype B, whereas the reverse was true for subtype E. Identification and resolution of the problem of invalid runs markedly improved the quality of HIV-1 viral load testing. The variability observed between laboratories and between assays, even the most recent versions, dictates that monitoring of viral load in an individual should always be by the same laboratory and by the same assay. Results for an individual which differ by less than 0.5 log10 HIV-1 RNA copy number/ml should not be considered clinically significant. PMID:11060062
Seguí, María del Mar; Cabrero-García, Julio; Crespo, Ana; Verdú, José; Ronda, Elena
2015-06-01
To design and validate a questionnaire to measure visual symptoms related to exposure to computers in the workplace. Our computer vision syndrome questionnaire (CVS-Q) was based on a literature review and validated through discussion with experts and performance of a pretest, pilot test, and retest. Content validity was evaluated by occupational health, optometry, and ophthalmology experts. Rasch analysis was used in the psychometric evaluation of the questionnaire. Criterion validity was determined by calculating the sensitivity and specificity, receiver operator characteristic curve, and cutoff point. Test-retest repeatability was tested using the intraclass correlation coefficient (ICC) and concordance by Cohen's kappa (κ). The CVS-Q was developed with wide consensus among experts and was well accepted by the target group. It assesses the frequency and intensity of 16 symptoms using a single rating scale (symptom severity) that fits the Rasch rating scale model well. The questionnaire has sensitivity and specificity over 70% and achieved good test-retest repeatability both for the scores obtained [ICC = 0.802; 95% confidence interval (CI): 0.673, 0.884] and CVS classification (κ = 0.612; 95% CI: 0.384, 0.839). The CVS-Q has acceptable psychometric properties, making it a valid and reliable tool to control the visual health of computer workers, and can potentially be used in clinical trials and outcome research. Copyright © 2015 Elsevier Inc. All rights reserved.
Matsumoto-Shimamori, Sachiyo; Ito, Tomohiko; Fukuda, Suzy E; Fukuda, Shinji
2011-09-01
Shimamori and Ito (2007 , Syllable weight and phonological encoding in Japanese children who stutter. Japanese Journal of Special Education, 44, 451-462; 2008, Syllable weight and frequency of stuttering: Comparison between children who stutter with and without a family history of stuttering. Japanese Journal of Special Education, 45, 437-445; 2009, Difference in frequency of stuttering between light and heavy syllables in the production of monosyllables: From the viewpoint of phonetic transition. The Japanese Journal of Logopedics and Phoniatrics, 50, 116-122 (in Japanese)) proposed the hypothesis that in Japanese the transition from the core vowels (CVs) to the following segments affected the occurrence of stuttering. However, the transition we investigated was in the first syllables only, and the effect of the transition in second, third and fourth syllables was not addressed. The purpose of this study was to investigate whether the transition from the CVs in the second, third and fourth syllables affected the occurrence of stuttering. The participants were 21 Japanese children. A non-word naming task and a non-word reading task were used. The frequency of stuttering was not significantly different where the number of transitions from the CVs differed on either task. These results suggest that the transition from the CVs in the second, third and fourth syllables does not have a significant effect on the occurrence of stuttering in Japanese.
Lopez, Christophe; Nakul, Estelle; Preuss, Nora; Elzière, Maya; Mast, Fred W
2018-06-06
There is increasing evidence that vestibular disorders evoke deficits reaching far beyond imbalance, oscillopsia and spatial cognition. Yet, how vestibular disorders affect own-body representations, in particular the perceived body shape and size, has been overlooked. Here, we explored vestibular contributions to own-body representations using two approaches. Study 1 measured the occurrence and severity of distorted own-body representations in 60 patients with dizziness and 60 healthy controls using six items from the Cambridge Depersonalization Scale. 12% of the patients have experienced distorted own-body representations (their hands or feet felt larger or smaller), 37% reported abnormal sense of agency, 35% reported disownership for the body, and 22% reported disembodiment. These proportions were larger in patients than controls. Study 2 aimed at testing whether artificial stimulation of the vestibular apparatus produced comparable distortions of own-body representations in healthy volunteers. We compared the effects of right-warm/left-cold caloric vestibular stimulation (CVS), left-warm/right-cold CVS and sham CVS on internal models of the left and right hands using a pointing task. The perceived length of the dorsum of the hand was increased specifically during left-warm/right-cold CVS, and this effect was found for both hands. Our studies show a vestibular contribution to own-body representations and should help understand the complex symptomatology of patients with dizziness.
Ayaki, Masahiko; Iwasawa, Atsuo; Niwano, Yoshimi
2012-01-01
We evaluated the in vitro cytotoxicity of benzalkonium chloride (BAK)-containing antiglaucoma eyedrops. We prepared cell cultures of SIRC, BCE C/D-1b, RC-1, and Chang conjunctiva. The viability of cell cultures was determined using the MTT and neutral red assays. The cell viability score (CVS) was used to compare the toxicity of test solutions. %CVS50 and %CVS40/80 of each eyedrop solution were 71 and 26 for Lumigan(®) (0.002% bimatoprost with 0.005% BAK), 100 and 99 for Tapros(®) (0.0015% tafluprost, a new formula from 2010 with 0.001% BAK), 39 and -29 for 2% Trusopt(®) (2% dorzolamide with 0.0075% BAK), 28 and -43 for Xalacom(®) (latanoprost/0.5% timolol with 0.02% BAK), 88 and 66 for DuoTrav(®) (travoprost/0.5% timolol with no BAK), 36 and -35 for Cosopt(®) (2% dorzolamide/0.5% timolol with 0.0075% BAK) and 53 and -1 for Combigan(®) (0.15% brimonidin/0.5% timolol with 0.005% BAK). Only Xalacom(®) and Tapros(®) did not show an apparent decrease in %CVS as compared to the corresponding concentration of BAK. In conclusion, the cytotoxicity of tested eyedrops was dependent on BAK. Only the eyedrops containing latanoprost or tafluprost showed a reduction in the cytotoxicity of BAK.
Hussein, Hussein Awad; Staufenbiel, Rudolf
2017-10-04
Determination of ceruloplasmin (Cp) activity in plasma can provide an objective measure of the health of dairy cows as well as it can be used for various diagnostic purposes. The current study was designed to perform an analytical validation of a method for the determination of plasma Cp activity in dairy cows and to evaluate the influences of plasma storage times and temperatures as well as freeze-thaw cycles on the activity of this enzyme. This cohort was carried out on ten cows. For each cow, 24 aliquots of plasma, which were stored at different temperature regimes, were prepared. Both intra- and interassay coefficients of variation (CVs) were determined. The linearity was evaluated using bovine plasma Cp standard. The mean values of intra- and interassay CVs were 1.08 and 2.12%, respectively. Results of linearity testing showed a high correlation coefficient (r = 0.998, P < 0.001). After 3 days of storage at room temperature and refrigeration, the plasma activity of Cp was significantly lowered (P < 0.05). Plasma samples kept at freezing for 3 months revealed insignificant changes in the activity of Cp. Repeated freeze-thaw cycles for three times had no significant influence on the activity of Cp. The method is easy and may be valid at values of Cp ranging from 100 to 1000 mg/L. It seems that keeping of plasma samples at room temperature and refrigeration longer than 3 days is unsuitable for Cp measurement. In addition, Cp remains stable in plasma samples stored at freezing as well as repeat freeze-thaw cycles.
Agger, Sean A.; Marney, Luke C.; Hoofnagle, Andrew N.
2011-01-01
BACKGROUND If liquid-chromatography–multiple-reaction–monitoring mass spectrometry (LC-MRM/MS) could be used in the large-scale preclinical verification of putative biomarkers, it would obviate the need for the development of expensive immunoassays. In addition, the translation of novel biomarkers to clinical use would be accelerated if the assays used in preclinical studies were the same as those used in the clinical laboratory. To validate this approach, we developed a multiplexed assay for the quantification of 2 clinically well-known biomarkers in human plasma, apolipoprotein A-I and apolipoprotein B (apoA-I and apoB). METHODS We used PeptideAtlas to identify candidate peptides. Human samples were denatured with urea or trifluoroethanol, reduced and alkylated, and digested with trypsin. We compared reversed-phase chromatographic separation of peptides with normal flow and microflow, and we normalized endogenous peptide peak areas to internal standard peptides. We evaluated different methods of calibration and compared the final method with a nephelometric immunoassay. RESULTS We developed a final method using trifluoroethanol denaturation, 21-h digestion, normal flow chromatography-electrospray ionization, and calibration with a single normal human plasma sample. For samples injected in duplicate, the method had intraassay CVs <6% and interassay CVs <12% for both proteins, and compared well with immunoassay (n = 47; Deming regression, LC-MRM/MS = 1.17 × immunoassay – 36.6; Sx|y = 10.3 for apoA-I and LC-MRM/MS = 1.21 × immunoassay + 7.0; Sx|y = 7.9 for apoB). CONCLUSIONS Multiplexed quantification of proteins in human plasma/serum by LC-MRM/MS is possible and compares well with clinically useful immunoassays. The potential application of single-point calibration to large clinical studies could simplify efforts to reduce day-to-day digestion variability. PMID:20923952
Factors influencing physical and technical variability in the English Premier League.
Bush, Michael D; Archer, David T; Hogg, Robert; Bradley, Paul S
2015-10-01
To investigate match-to-match variability of physical and technical performances in English Premier League players and quantify the influence of positional and contextual factors. Match data (N = 451) were collected using a multicamera computerized tracking system across multiple seasons (2005-06 to 2012-13). The coefficient of variation (CV) was calculated from match to match for physical and technical performances in selected positions across different match contexts (location, standard, and result). Wide midfielders demonstrated the greatest CVs for total distance (4.9% ± 5.9%) and central midfielders the smallest (3.6% ± 2.0%); nevertheless, all positions exhibited CVs <5% (P > .05, effect size [ES] 0.1-0.3). Central defenders demonstrated the greatest CVs and wide midfielders the lowest for both high-intensity running (20.2% ± 8.8% and 13.7% ± 7.7%, P < .05, ES 0.4-0.8) and sprint distance (32.3% ± 13.8% and 22.6% ± 11.2%, P < .05, ES 0.5-0.8). Technical indicators such as tackles (83.7% ± 42.3%), possessions won (47.2% ± 27.9%), and interceptions (59.1% ± 37.3%) illustrated substantial variability for attackers compared with all other positions (P < .05, ES 0.4-1.1). Central defenders demonstrated large variability for the number of times tackled per match (144.9% ± 58.3%) and passes attempted and received compared with other positions (39.2% ± 17.5% and 46.9% ± 20.2%, P < .001, ES 0.6-1.8). Contextual factors had limited impact on the variability of physical and technical parameters. The data demonstrate that technical parameters varied more from match to match than physical parameters. Defensive players (fullbacks and central defenders) displayed higher CVs for offensive technical variables, while attacking players (attackers and wide midfielders) exhibited higher CVs for defensive technical variables. Physical and technical performances are variable per se regardless of context.
NASA Astrophysics Data System (ADS)
Wang, Fang; Yang, Song
2018-02-01
Using principal component (PC) analysis, three leading modes of cloud vertical structure (CVS) are revealed by the GCM-Oriented CALIPSO Cloud Product (GOCCP), i.e. tropical high, subtropical anticyclonic and extratropical cyclonic cloud modes (THCM, SACM and ECCM, respectively). THCM mainly reflect the contrast between tropical high clouds and clouds in middle/high latitudes. SACM is closely associated with middle-high clouds in tropical convective cores, few-cloud regimes in subtropical anticyclonic clouds and stratocumulus over subtropical eastern oceans. ECCM mainly corresponds to clouds along extratropical cyclonic regions. Models of phase 2 of Cloud Feedback Model Intercomparison Project (CFMIP2) well reproduce the THCM, but SACM and ECCM are generally poorly simulated compared to GOCCP. Standardized PCs corresponding to CVS modes are generally captured, whereas original PCs (OPCs) are consistently underestimated (overestimated) for THCM (SACM and ECCM) by CFMIP2 models. The effects of CVS modes on relative cloud radiative forcing (RSCRF/RLCRF) (RSCRF being calculated at the surface while RLCRF at the top of atmosphere) are studied in terms of principal component regression method. Results show that CFMIP2 models tend to overestimate (underestimated or simulate the opposite sign) RSCRF/RLCRF radiative effects (REs) of ECCM (THCM and SACM) in unit global mean OPC compared to observations. These RE biases may be attributed to two factors, one of which is underestimation (overestimation) of low/middle clouds (high clouds) (also known as stronger (weaker) REs in unit low/middle (high) clouds) in simulated global mean cloud profiles, the other is eigenvector biases in CVS modes (especially for SACM and ECCM). It is suggested that much more attention should be paid on improvement of CVS, especially cloud parameterization associated with particular physical processes (e.g. downwelling regimes with the Hadley circulation, extratropical storm tracks and others), which may be crucial to reduce the CRF biases in current climate models.
NASA Astrophysics Data System (ADS)
Kamae, Tuneyoshi; Lee, Shiu-Hang; Makishima, Kazuo; Shibata, Shinpei; Shigeyama, Toshikazu
2018-03-01
Recent observations found that electrons are accelerated to ˜10 GeV and emit synchrotron hard X-rays in two magnetic white dwarfs (WDs), also known as cataclysmic variables (CVs). In nova outbursts of WDs, multi-GeV gamma-rays were detected, implying that protons are accelerated to 100 GeV or higher. In recent optical surveys, the WD density is found to be higher near the Sun than in the Galactic disk by a factor ˜2.5. The cosmic rays (CRs) produced by local CVs and novae will accumulate in the local bubble for 106-107 yr. On these findings, we search for CRs from historic CVs and novae in the observed CR spectra. We model the CR spectra at the heliopause as sums of Galactic and local components based on observational data as much as possible. The initial Galactic CR electron and proton spectra are deduced from the gamma-ray emissivity, the local electron spectrum from the hard X-ray spectra at the CVs, and the local proton spectrum from gamma-ray spectra at novae. These spectral shapes are then expressed in a simple set of polynomial functions of CR energy and regressively fitted until the high-energy (>100 GeV) CR spectra near Earth and the Voyager-1 spectra at the heliopause are reproduced. We then extend the modeling to nuclear CR spectra and find that one spectral shape fits all local nuclear CRs, and that the apparent hardening of the nuclear CR spectra is caused by the roll-down of local nuclear spectra around 100-200 GeV. All local CR spectra populate a limited energy band below 100-200 GeV and enhance gamma-ray emissivity below ˜10 GeV. Such an enhancement is observed in the inner Galaxy, suggesting the CR fluxes from CVs and novae are substantially higher there.
Longitudinal safety evaluation of connected vehicles' platooning on expressways.
Rahman, Md Sharikur; Abdel-Aty, Mohamed
2018-08-01
Connected vehicles (CV) technology has recently drawn an increasing attention from governments, vehicle manufacturers, and researchers. One of the biggest issues facing CVs popularization associates it with the market penetration rate (MPR). The full market penetration of CVs might not be accomplished recently. Therefore, traffic flow will likely be composed of a mixture of conventional vehicles and CVs. In this context, the study of CV MPR is worthwhile in the CV transition period. The overarching goal of this study was to evaluate longitudinal safety of CV platoons by comparing the implementation of managed-lane CV platoons and all lanes CV platoons (with same MPR) over non-CV scenario. This study applied the CV concept on a congested expressway (SR408) in Florida to improve traffic safety. The Intelligent Driver Model (IDM) along with the platooning concept were used to regulate the driving behavior of CV platoons with an assumption that the CVs would follow this behavior in real-world. A high-level control algorithm of CVs in a managed-lane was proposed in order to form platoons with three joining strategies: rear join, front join, and cut-in joint. Five surrogate safety measures, standard deviation of speed, time exposed time-to-collision (TET), time integrated time-to-collision (TIT), time exposed rear-end crash risk index (TERCRI), and sideswipe crash risk (SSCR) were utilized as indicators for safety evaluation. The results showed that both CV approaches (i.e., managed-lane CV platoons, and all lanes CV platoons) significantly improved the longitudinal safety in the studied expressway compared to the non-CV scenario. In terms of surrogate safety measures, the managed-lane CV platoons significantly outperformed all lanes CV platoons with the same MPR. Different time-to-collision (TTC) thresholds were also tested and showed similar results on traffic safety. Results of this study provide useful insight for the management of CV MPR as managed-lane CV platoons. Copyright © 2017 Elsevier Ltd. All rights reserved.
The Evolution of Cataclysmic Variables as Revealed by Their Donor Stars
NASA Astrophysics Data System (ADS)
Knigge, Christian; Baraffe, Isabelle; Patterson, Joseph
2011-06-01
We present an attempt to reconstruct the complete evolutionary path followed by cataclysmic variables (CVs), based on the observed mass-radius relationship of their donor stars. Along the way, we update the semi-empirical CV donor sequence presented previously by one of us, present a comprehensive review of the connection between CV evolution and the secondary stars in these systems, and reexamine most of the commonly used magnetic braking (MB) recipes, finding that even conceptually similar ones can differ greatly in both magnitude and functional form. The great advantage of using donor radii to infer mass-transfer and angular-momentum-loss (AML) rates is that they sample the longest accessible timescales and are most likely to represent the true secular (evolutionary average) rates. We show explicitly that if CVs exhibit long-term mass-transfer-rate fluctuations, as is often assumed, the expected variability timescales are so long that other tracers of the mass-transfer rate—including white dwarf (WD) temperatures—become unreliable. We carefully explore how much of the radius difference between CV donors and models of isolated main-sequence stars may be due to mechanisms other than mass loss. The tidal and rotational deformation of Roche-lobe-filling stars produces ~= 4.5% radius inflation below the period gap and ~= 7.9% above. A comparison of stellar models to mass-radius data for non-interacting stars suggests a real offset of ~= 1.5% for fully convective stars (i.e., donors below the gap) and ~= 4.9% for partially radiative ones (donors above the gap). We also show that donor bloating due to irradiation is probably smaller than, and at most comparable to, these effects. After calibrating our models to account for these issues, we fit self-consistent evolution sequences to our compilation of donor masses and radii. In the standard model of CV evolution, AMLs below the period gap are assumed to be driven solely by gravitational radiation (GR), while AMLs above the gap are usually described by an MB law first suggested by Rappaport et al. We adopt simple scaled versions of these AML recipes and find that these are able to match the data quite well. The optimal scaling factors turn out to be f GR = 2.47 ± 0.22 below the gap and f MB = 0.66 ± 0.05 above (the errors here are purely statistical, and the standard model corresponds to f GR = f MB = 1). This revised model describes the mass-radius data significantly better than the standard model. Some of the most important implications and applications of our results are as follows. (1) The revised evolution sequence yields correct locations for the minimum period and the upper edge of the period gap; the standard sequence does not. (2) The observed spectral types of CV donors are compatible with both standard and revised models. (3) A direct comparison of predicted and observed WD temperatures suggests an even higher value for f GR, but this comparison is sensitive to the assumed mean WD mass and the possible existence of mass-transfer-rate fluctuations. (4) The predicted absolute magnitudes of donor stars in the near-infrared form a lower envelope around the observed absolute magnitudes for systems with parallax distances. This is true for all of our sequences, so any of them can be used to set firm lower limits on (or obtain rough estimates of) the distances toward CVs based only on P orb and single epoch near-IR measurements. (5) Both standard and revised sequences predict that short-period CVs should be susceptible to dwarf nova (DN) eruptions, consistent with observations. However, both sequences also predict that the fraction of DNe among long-period CVs should decline with P orb above the period gap. Observations suggest the opposite behavior, and we discuss the possible explanations for this discrepancy. (6) Approximate orbital period distributions constructed from our evolution sequences suggest that the ratio of long-period CVs to short-period, pre-bounce CVs is about 3 × higher for the revised sequence than the standard one. This may resolve a long-standing problem in CV evolution. Tables describing our donor and evolution sequences are provided in electronically readable form.
40 CFR 86.119-90 - CVS calibration.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Pressure depression upstream of LFE EPI in. H2O (kPa) ±0.05 in. H20 (±0.012 kPa) Pressure drop across the...) ±0.5 °F (±0.3 °C) Pressure depression at CVS pump inlet PPI in. fluid (kPa) ±0.05 in. fluid (±0.022 k... depression (about 4 in. H2O (1.0 kPa) that will yield a minimum of six data points for the total calibration...
40 CFR 86.119-90 - CVS calibration.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Pressure depression upstream of LFE EPI in. H2O (kPa) ±0.05 in. H20 (±0.012 kPa) Pressure drop across the...) ±0.5 °F (±0.3 °C) Pressure depression at CVS pump inlet PPI in. fluid (kPa) ±0.05 in. fluid (±0.022 k... depression (about 4 in. H2O (1.0 kPa) that will yield a minimum of six data points for the total calibration...
40 CFR 86.119-90 - CVS calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Pressure depression upstream of LFE EPI in. H2O (kPa) ±0.05 in. H20 (±0.012 kPa) Pressure drop across the...) ±0.5 °F (±0.3 °C) Pressure depression at CVS pump inlet PPI in. fluid (kPa) ±0.05 in. fluid (±0.022 k... depression (about 4 in. H2O (1.0 kPa) that will yield a minimum of six data points for the total calibration...
40 CFR 86.119-90 - CVS calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Pressure depression upstream of LFE EPI in. H2O (kPa) ±0.05 in. H20 (±0.012 kPa) Pressure drop across the...) ±0.5 °F (±0.3 °C) Pressure depression at CVS pump inlet PPI in. fluid (kPa) ±0.05 in. fluid (±0.022 k... depression (about 4 in. H2O (1.0 kPa) that will yield a minimum of six data points for the total calibration...
40 CFR 86.119-90 - CVS calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Pressure depression upstream of LFE EPI in. H2O (kPa) ±0.05 in. H20 (±0.012 kPa) Pressure drop across the...) ±0.5 °F (±0.3 °C) Pressure depression at CVS pump inlet PPI in. fluid (kPa) ±0.05 in. fluid (±0.022 k... depression (about 4 in. H2O (1.0 kPa) that will yield a minimum of six data points for the total calibration...
Hans T. Schreuder; Jin-Mann S. Lin; John Teply
2000-01-01
We estimate number of tree species in National Forest populations using the nonparametric estimator. Data from the Current Vegetation Survey (CVS) of Region 6 of the USDA Forest Service were used to estimate the number of tree species with a plot close in size to the Forest Inventory and Analysis (FIA) plot and the actual CVS plot for the 5.5 km FIA grid and the 2.7 km...
Lopez, Marcelo F; Doremus-Fitzwater, Tamara L; Becker, Howard C
2011-06-01
Experience with stress situations during early development can have long-lasting effects on stress- and anxiety-related behaviors. Importantly, this can also favor drug self-administration. These studies examined the effects of chronic social isolation and/or variable stress experiences during early development on subsequent voluntary ethanol intake in adult male and female C57BL/6J mice. The experiments were conducted to evaluate the effect of chronic isolation between weaning and adulthood (Experiment 1), chronic isolation during adulthood (Experiment 2), and chronic variable stress (CVS) alone or in combination with chronic social isolation between weaning and adulthood (Experiment 3) on subsequent voluntary ethanol intake. Mice were born in our facility and were separated into two housing conditions: isolate housed (one mouse/cage) or group housed (four mice/cage) according to sex. Separate groups were isolated for 40 days starting either at time of weaning postnatal day 21 (PD 21) (early isolation, Experiments 1 and 3) or at adulthood (PD 60: late isolation, Experiment 2). The effects of housing condition on subsequent ethanol intake were assessed starting at around PD 65 in Experiments 1 and 3 or PD 105 days in Experiment 2. In Experiment 3, starting at PD 32, isolate-housed and group-housed mice were either subjected to CVS or left undisturbed. CVS groups experienced random presentations of mild stressors for 14 days, including exposure to an unfamiliar open field, restraint, physical shaking, and forced swim, among others. All mice were tested for ethanol intake for 14 days using a two-bottle choice (ethanol 15% vol/vol vs. water) for a 2-h limited access procedure. Early social isolation resulted in greater ethanol intake compared with the corresponding group-housed mice (Experiment 1). In contrast, social isolation during adulthood (late isolation) did not increase subsequent ethanol intake compared with the corresponding group-housed mice (Experiment 2). For mice that did not experience CVS, early social isolation resulted in greater ethanol intake compared with group-housed mice (Experiment 3). CVS subsequently resulted in a significant increase in ethanol intake in group-housed mice, but CVS failed to further increase ethanol intake in mice that experienced chronic social isolation early in life (Experiment 3). Overall, female mice consumed more ethanol than males, whether isolated (early or late) or group housed. These results indicate that early but not late social isolation can subsequently influence ethanol consumption in C57BL/6J mice. Thus, the developmental timing of chronic social isolation appears to be an important factor in defining later effects on ethanol self-administration behavior. In addition, experience with CVS early in life results in elevated ethanol intake later in adulthood. Taken together, these results emphasize the important role of early stress experiences that modulate later voluntary ethanol intake during adulthood. Copyright © 2011 Elsevier Inc. All rights reserved.
Srikrishna, Devabhaktuni; Coram, Marc A
2011-01-01
Author-supplied citations are a fraction of the related literature for a paper. The "related citations" on PubMed is typically dozens or hundreds of results long, and does not offer hints why these results are related. Using noun phrases derived from the sentences of the paper, we show it is possible to more transparently navigate to PubMed updates through search terms that can associate a paper with its citations. The algorithm to generate these search terms involved automatically extracting noun phrases from the paper using natural language processing tools, and ranking them by the number of occurrences in the paper compared to the number of occurrences on the web. We define search queries having at least one instance of overlap between the author-supplied citations of the paper and the top 20 search results as citation validated (CV). When the overlapping citations were written by same authors as the paper itself, we define it as CV-S and different authors is defined as CV-D. For a systematic sample of 883 papers on PubMed Central, at least one of the search terms for 86% of the papers is CV-D versus 65% for the top 20 PubMed "related citations." We hypothesize these quantities computed for the 20 million papers on PubMed to differ within 5% of these percentages. Averaged across all 883 papers, 5 search terms are CV-D, and 10 search terms are CV-S, and 6 unique citations validate these searches. Potentially related literature uncovered by citation-validated searches (either CV-S or CV-D) are on the order of ten per paper--many more if the remaining searches that are not citation-validated are taken into account. The significance and relationship of each search result to the paper can only be vetted and explained by a researcher with knowledge of or interest in that paper.
Srikrishna, Devabhaktuni; Coram, Marc A.
2011-01-01
Author-supplied citations are a fraction of the related literature for a paper. The “related citations” on PubMed is typically dozens or hundreds of results long, and does not offer hints why these results are related. Using noun phrases derived from the sentences of the paper, we show it is possible to more transparently navigate to PubMed updates through search terms that can associate a paper with its citations. The algorithm to generate these search terms involved automatically extracting noun phrases from the paper using natural language processing tools, and ranking them by the number of occurrences in the paper compared to the number of occurrences on the web. We define search queries having at least one instance of overlap between the author-supplied citations of the paper and the top 20 search results as citation validated (CV). When the overlapping citations were written by same authors as the paper itself, we define it as CV-S and different authors is defined as CV-D. For a systematic sample of 883 papers on PubMed Central, at least one of the search terms for 86% of the papers is CV-D versus 65% for the top 20 PubMed “related citations.” We hypothesize these quantities computed for the 20 million papers on PubMed to differ within 5% of these percentages. Averaged across all 883 papers, 5 search terms are CV-D, and 10 search terms are CV-S, and 6 unique citations validate these searches. Potentially related literature uncovered by citation-validated searches (either CV-S or CV-D) are on the order of ten per paper – many more if the remaining searches that are not citation-validated are taken into account. The significance and relationship of each search result to the paper can only be vetted and explained by a researcher with knowledge of or interest in that paper. PMID:21935487
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrison, Thomas E.; Marra, Rachel E., E-mail: tharriso@nmsu.edu, E-mail: rmarra@nmsu.edu
We present new moderate-resolution near-infrared spectroscopy of three CVs obtained using GNIRS on Gemini-North. These spectra covered three {sup 13}CO bandheads found in the K -band, allowing us to derive the isotopic abundance ratios for carbon. We find small {sup 12}C/{sup 13}C ratios for all three donor stars. In addition, these three objects show carbon deficits, with AE Aqr being the most extreme ([C/Fe] = −1.4). This result confirms the conjecture that the donor stars in some long-period CVs have undergone considerable nuclear evolution prior to becoming semi-contact binaries. In addition to the results for carbon, we find that themore » abundance of sodium is enhanced in these three objects, and the secondary stars in both RU Peg and SS Cyg suffer magnesium deficits. Explaining such anomalies appears to require higher mass progenitors than commonly assumed for the donor stars of CVs.« less
NASA Astrophysics Data System (ADS)
Edmonds, Peter D.; Gilliland, Ronald L.; Heinke, Craig O.; Grindlay, Jonathan E.
2003-10-01
We report in this study of 47 Tucanae the largest number of optical identifications of X-ray sources yet obtained in a single globular cluster. Using deep Chandra ACIS-I imaging and extensive Hubble Space Telescope studies with Wide Field Planetary Camera 2 (WFPC2; including a 120 orbit program giving superb V and I images), we have detected optical counterparts to at least 22 cataclysmic variables (CVs) and 29 chromospherically active binaries (BY Dra and RS CVn systems) in 47 Tuc. These identifications are all based on tight astrometric matches between X-ray sources and objects with unusual (non-main-sequence [non-MS]) optical colors and/or optical variability. Several other CVs and active binaries have likely been found, but these have marginal significance because of larger offsets between the X-ray and optical positions, or colors and variability that are not statistically convincing. These less secure optical identifications are not subsequently discussed in detail. In the U versus U-V color-magnitude diagram (CMD), where the U band corresponds to either F336W or F300W, the CVs all show evidence for blue colors compared with the MS, but most of them fall close to the main sequence in the V versus V-I CMD, showing that the secondary stars dominate the optical light. The X-ray-detected active binaries have magnitude offsets above the MS (in both the U versus U-V or V versus V-I CMDs) that are indistinguishable from those of the much larger sample of optical variables (eclipsing and contact binaries and BY Dra variables) detected in the recent WFPC2 studies of Albrow et al. We also present the results of a new, deeper search for optical companions to millisecond pulsars (MSPs). One possible optical companion to an MSP (47 Tuc T) was found, adding to the two optical companions already known. Finally, we study several blue stars with periodic variability from Albrow et al. that show little or no evidence for X-ray emission. The optical colors of these objects differ from those of 47 Tuc (and field) CVs. An accompanying paper will present time series results for these optical identifications and will discuss X-ray-to-optical flux ratios, spatial distributions, and an overall interpretation of the results. Based on observations with the NASA/ESA Hubble Space Telescope obtained at STScI, which is operated by AURA, Inc., under NASA contract NAS 5-26555.
Zheng, Zhi; Luo, Yuling; McMaster, Gary K
2006-07-01
Accurate and precise quantification of mRNA in whole blood is made difficult by gene expression changes during blood processing, and by variations and biases introduced by sample preparations. We sought to develop a quantitative whole-blood mRNA assay that eliminates blood purification, RNA isolation, reverse transcription, and target amplification while providing high-quality data in an easy assay format. We performed single- and multiplex gene expression analysis with multiple hybridization probes to capture mRNA directly from blood lysate and used branched DNA to amplify the signal. The 96-well plate singleplex assay uses chemiluminescence detection, and the multiplex assay combines Luminex-encoded beads with fluorescent detection. The single- and multiplex assays could quantitatively measure as few as 6000 and 24,000 mRNA target molecules (0.01 and 0.04 amoles), respectively, in up to 25 microL of whole blood. Both formats had CVs < 10% and dynamic ranges of 3-4 logs. Assay sensitivities allowed quantitative measurement of gene expression in the minority of cells in whole blood. The signals from whole-blood lysate correlated well with signals from purified RNA of the same sample, and absolute mRNA quantification results from the assay were similar to those obtained by quantitative reverse transcription-PCR. Both single- and multiplex assay formats were compatible with common anticoagulants and PAXgene-treated samples; however, PAXgene preparations induced expression of known antiapoptotic genes in whole blood. Both the singleplex and the multiplex branched DNA assays can quantitatively measure mRNA expression directly from small volumes of whole blood. The assay offers an alternative to current technologies that depend on RNA isolation and is amenable to high-throughput gene expression analysis of whole blood.
Marahatta, Anu; Megaraj, Vandana; McGann, Patrick T; Ware, Russell E; Setchell, Kenneth D R
2016-12-01
Sickle cell anemia (SCA) is a life-threatening blood disorder characterized by the presence of sickle-shaped erythrocytes. Hydroxyurea is currently the only US Food and Drug Administration-approved treatment and there is a need for a convenient method to monitor compliance and hydroxyurea concentrations, especially in pediatric SCA patients. We describe a novel approach to the determination of hydroxyurea concentrations in dried whole blood collected on DMPK-C cards or volumetric absorptive microsampling (VAMS) devices. Hydroxyurea was quantified by electrospray ionization LC-MS/MS using [ 13 C 15 N 2 ]hydroxyurea as the internal standard. Calibrators were prepared in whole blood applied to DMPK-C cards or VAMS devices. Calibration curves for blood hydroxyurea measured from DMPK-C cards and VAMS devices were linear over the range 0.5-60 μg/mL. Interassay and intraassay CVs were <15% for blood collected by both methods, and the limit of detection was 5 ng/mL. Whole blood hydroxyurea was stable for up to 60 days on DMPK-C cards and VAMS devices when frozen at -20 °C or -80 °C. Whole blood hydroxyurea concentrations in samples collected on DMPK-C cards or VAMS devices from SCA patients were in close agreement. This tandem mass spectrometry method permits measurement of hydroxyurea concentrations in small volumes of dried blood applied to either DMPK-C cards or VAMS devices with comparable performance. This method for measuring hydroxyurea from dried blood permits the evaluation of therapeutic drug monitoring, individual pharmacokinetics, and medication adherence using heel/finger-prick samples from pediatric patients with SCA treated with hydroxyurea. © 2016 American Association for Clinical Chemistry.
Kortebi, Mounia; Milohanic, Eliane; Mitchell, Gabriel; Péchoux, Christine; Prevost, Marie-Christine; Cossart, Pascale; Bierne, Hélène
2017-11-01
Listeria monocytogenes causes listeriosis, a foodborne disease that poses serious risks to fetuses, newborns and immunocompromised adults. This intracellular bacterial pathogen proliferates in the host cytosol and exploits the host actin polymerization machinery to spread from cell-to-cell and disseminate in the host. Here, we report that during several days of infection in human hepatocytes or trophoblast cells, L. monocytogenes switches from this active motile lifestyle to a stage of persistence in vacuoles. Upon intercellular spread, bacteria gradually stopped producing the actin-nucleating protein ActA and became trapped in lysosome-like vacuoles termed Listeria-Containing Vacuoles (LisCVs). Subpopulations of bacteria resisted degradation in LisCVs and entered a slow/non-replicative state. During the subculture of host cells harboring LisCVs, bacteria showed a capacity to cycle between the vacuolar and the actin-based motility stages. When ActA was absent, such as in ΔactA mutants, vacuolar bacteria parasitized host cells in the so-called "viable but non-culturable" state (VBNC), preventing their detection by conventional colony counting methods. The exposure of infected cells to high doses of gentamicin did not trigger the formation of LisCVs, but selected for vacuolar and VBNC bacteria. Together, these results reveal the ability of L. monocytogenes to enter a persistent state in a subset of epithelial cells, which may favor the asymptomatic carriage of this pathogen, lengthen the incubation period of listeriosis, and promote bacterial survival during antibiotic therapy.
What the bird’s brain tells the bird’s eye: the function of descending input to the avian retina
Wilson, Martin; Lindstrom, Sarah H.
2012-01-01
As Cajal discovered in the late 19th century, the bird retina receives a substantial input from the brain. Approximately 10,000 fibers originating in a small midbrain nucleus, the isthmo-optic nucleus, terminate in each retina. The input to the isthmo-optic nucleus is chiefly from the optic tectum which, in the bird, is the primary recipient of retinal input. These neural elements constitute a closed loop, the Centrifugal Visual System (CVS), beginning and ending in the retina, that delivers positive feedback to active ganglion cells. Several features of the system are puzzling. All fibers from the isthmo-optic nucleus terminate in the ventral retina and an unusual axon-bearing amacrine cell, the Target Cell, is the postsynaptic partner of these fibers. While the rest of the CVS is orderly and retinotopic, Target Cell axons project seemingly at random, mostly to distant parts of the retina. We review here the most significant features of the anatomy and physiology of the CVS with a view to understanding its function. We suggest that many of the facts about this system, including some that are otherwise difficult to explain, can be accommodated within the hypothesis that the images of shadows cast on the ground or on objects in the environment, initiate a rapid and parallel search of the sky for a possible aerial predator. If a predator is located, shadow and predator would be temporarily linked together and tracked by the CVS. PMID:21524338
Mitchell, Gabriel
2017-01-01
Listeria monocytogenes causes listeriosis, a foodborne disease that poses serious risks to fetuses, newborns and immunocompromised adults. This intracellular bacterial pathogen proliferates in the host cytosol and exploits the host actin polymerization machinery to spread from cell-to-cell and disseminate in the host. Here, we report that during several days of infection in human hepatocytes or trophoblast cells, L. monocytogenes switches from this active motile lifestyle to a stage of persistence in vacuoles. Upon intercellular spread, bacteria gradually stopped producing the actin-nucleating protein ActA and became trapped in lysosome-like vacuoles termed Listeria-Containing Vacuoles (LisCVs). Subpopulations of bacteria resisted degradation in LisCVs and entered a slow/non-replicative state. During the subculture of host cells harboring LisCVs, bacteria showed a capacity to cycle between the vacuolar and the actin-based motility stages. When ActA was absent, such as in ΔactA mutants, vacuolar bacteria parasitized host cells in the so-called “viable but non-culturable” state (VBNC), preventing their detection by conventional colony counting methods. The exposure of infected cells to high doses of gentamicin did not trigger the formation of LisCVs, but selected for vacuolar and VBNC bacteria. Together, these results reveal the ability of L. monocytogenes to enter a persistent state in a subset of epithelial cells, which may favor the asymptomatic carriage of this pathogen, lengthen the incubation period of listeriosis, and promote bacterial survival during antibiotic therapy. PMID:29190284
Sturt, Ruth; Punt, T David
2013-01-01
The impact of spatial neglect remains a substantial challenge to patients undergoing rehabilitation following stroke. Beyond the relatively well-described implications for visuospatial function, neglect is increasingly shown to have a negative impact on the wider aspects of sensori-motor performance with corresponding implications for activities including gait and balance. Caloric vestibular stimulation (CVS) administered to the contralesional ear has previously been shown to improve performance in patients with spatial neglect. Here, in Experiment One, we investigated the effect of CVS on clinical measures of spatial neglect and postural control in three groups of patients following stroke; left brain damaged patients (LBD, n = 6), right brain damaged patients without neglect (RBD-, n = 6), and right brain damaged patients with neglect (RBD+ , n = 6). While post-stimulation scores demonstrated an improvement for participants with spatial neglect, further analysis of postural scores indicated that improvement was selective for asymmetrical activities, with symmetrical activities remaining unchanged. We interpret these results with reference to the related problem of extinction which predicts that activities demanding synchronous bilateral activity (symmetrical activities) would cause greater difficulties for patients with neglect. In Experiment Two, we tested a further six RBD+ patients on the same measures following CVS to the ipsilesional (right) ear. There was no significant improvement in perceptual or postural scores. Our findings are supportive of previous studies that demonstrate improvement in perception and movement for patients with spatial neglect following contralesional CVS and suggest that these improvements may have clinical benefits.
Kubica, Paweł; Kot-Wasik, Agata; Wasik, Andrzej; Namieśnik, Jacek
2013-05-10
Two analytical procedures are proposed where HILIC and RPLC techniques are coupled with tandem mass spectrometry detection for rapid determination of trace amounts of nicotine in zero-level liquids for electronic cigarettes. Samples are prepared on the basis of the approach "dilute & shoot" which makes this important step quick and not complicated. The chromatographic separation was carried out on a Zorbax XDB column (RPLC method) and Ascentis Si column (HILIC mode). Within-run precisions (CVs) measured at three concentration levels were as follows: 0.73%, 0.98% and 1.44% for RPLC method and 1.39%, 1.44% and 0.57% (HILIC mode). Between-run CVs were as follows: 1.94%, 1.02% and 1.22% for RPLC mode and 1.49%, 1.20% and 1.22% for HILIC mode. The detection limits of RPLC and HILIC modes were 4.08 and 3.90 ng/mL respectively. The proposed procedures are rapid, not complicated, sensitive and are suitable for fast determination of trace amounts of nicotine in zero-level liquids for electronic cigarettes. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Humeau-Heurtier, Anne; Mahé, Guillaume; Chapeau-Blondeau, François; Rousseau, David; Abraham, Pierre
2012-07-01
Time irreversibility can be qualitatively defined as the degree of a signal for temporal asymmetry. Recently, a time irreversibility characterization method based on entropies of positive and negative increments has been proposed for experimental signals and applied to heart rate variability (HRV) data (central cardiovascular system (CVS)). The results led to interesting information as a time asymmetry index was found different for young subjects and elderly people or heart disease patients. Nevertheless, similar analyses have not yet been conducted on laser Doppler flowmetry (LDF) signals (peripheral CVS). We first propose to further investigate the above-mentioned characterization method. Then, LDF signals, LDF signals reduced to samples acquired during ECG R peaks (LDF_RECG signals) and HRV recorded simultaneously in healthy subjects are processed. Entropies of positive and negative increments for LDF signals show a nonmonotonic pattern: oscillations—more or less pronounced, depending on subjects—are found with a period matching the one of cardiac activity. However, such oscillations are not found with LDF_RECG nor with HRV. Moreover, the asymmetry index for LDF is markedly different from the ones of LDF_RECG and HRV. The cardiac activity may therefore play a dominant role in the time irreversibility properties of LDF signals.
Introini, Andrea; Kaldensjö, Tove; Hirbod, Taha; Röhl, Maria; Tjernlund, Annelie; Andersson, Sonia; Broliden, Kristina
2014-11-01
Sex hormones can influence the immune defenses of the female genital tract (FGT) and its susceptibility to infections. Here we investigated the effect of different hormonal contraceptives on the production of antimicrobial peptides (AMPs) in different compartments of the female genital mucosa (FGM), secretions and tissue. Cervicovaginal secretions (CVS) and ectocervical tissue samples obtained from women using progesterone intrauterine devices (pIUD) (n = 23) and combined oral contraceptives (COC) (n = 23) were analyzed for the expression and in situ localization of HNP1-3, BD-2, LL-37, SLPI and trappin-2 by ELISA, real-time PCR and immunohistochemistry. Women using COC had significantly lower mRNA levels of BD-2 and trappin-2 in ectocervical tissue than pIUD users. The two groups showed no differences in CVS concentration, as well as similar in situ expression patterns in ectocervical tissue, of all five AMPs. The use of hormonal contraceptives influences AMP expression differently in genital secretions compared to ectocervical tissue. This suggests that the impact of sex hormones on local immune defenses varies in different compartments of the FGM, and likely in different locations across the FGT. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Zlotogora, Joël
2002-12-01
To determine the importance of various factors on the decisions whether to terminate or continue a pregnancy after an abnormal result. The decisions of 1467 women who had an abnormal result after an invasive prenatal test were examined according to their religion, the time of diagnosis and the severity of the disorder. When the examinations were performed by chorionic villus sampling (CVS) among both Jews and non-Jews most of the women opted to terminate the affected pregnancy. After amniocentesis the rate of termination of pregnancy was still very high among cases in which Down syndrome or other significant chromosomal aberrations were diagnosed among Jews. For all the other diagnostic groups either among Jews or non-Jews there was a significant proportion of the cases in which the women decided to continue the pregnancy. A significant exception about the decisions of the couples was in the case of hemoglobinopathy-affected pregnancies among Arabs since both after CVS and amniocentesis many women often decided to continue the pregnancy. The main factor in the decision to terminate or continue the pregnancy is the severity of the disorder diagnosed. However, among Arabs other factors are important, in particular the time at which the diagnosis is made. Copyright 2002 John Wiley & Sons, Ltd.
Midttun, Øivind; McCann, Adrian; Aarseth, Ove; Krokeide, Marit; Kvalheim, Gry; Meyer, Klaus; Ueland, Per M
2016-11-01
Targeted metabolic profiling characterized by complementary platforms, multiplexing and low volume consumption are increasingly used for studies using biobank material. Using liquid-liquid extraction, we developed a sample workup suitable for quantification of 6 fat- and 26 water-soluble biomarkers. 50 μL of serum/plasma was mixed with dithioerythritol, ethanol, and isooctane/chloroform. The organic layer was used for analysis of the fat-soluble vitamins all-trans retinol (A), 25-hydroxyvitamin D2, 25-hydroxyvitamin D3, α-tocopherol (E), γ-tocopherol (E), and phylloquinone (K1) by LC-MS/MS. The remaining aqueous fraction was mixed with ethanol, water, pyridine, and methylchloroformate (in toluene) to derivatize the water-soluble biomarkers. The resulting toluene layer was used for GC-MS/MS analysis of alanine, α-ketoglutarate, asparagine, aspartic acid, cystathionine, total cysteine, glutamic acid, glutamine, glycine, histidine, total homocysteine, isoleucine, kynurenine, leucine, lysine, methionine, methylmalonic acid, ornithine, phenylalanine, proline, sarcosine, serine, threonine, tryptophan, tyrosine, and valine. Isotope-labeled internal standards were used for all analytes. Chromatographic run times for the LC-MS/MS and GC-MS/MS were 4.5 and 11 min, respectively. The limits of detection (LOD) for the low-concentration analytes (25-hydroxyvitamin D2, 25-hydroxyvitamin D3, and phylloquinone) were 25, 17, and 0.33 nM, respectively, while all other analytes demonstrated sensitivity significantly lower than endogenous concentrations. Recoveries ranged from 85.5-109.9% and within- and between-day coefficients of variance (CVs) were 0.7-9.4% and 1.1-17.5%, respectively. This low-volume, high-throughput multianalyte assay is currently in use in our laboratory for quantification of 32 serum/plasma biomarkers in epidemiological studies.
CVs and millisecond pulsar progenitors in globular clusters
NASA Technical Reports Server (NTRS)
Grindlay, J. E.; Cool, A. M.; Bailyn, C. D.
1991-01-01
The recent discovery of a large population of millisecond pulsars in globular clusters, together with earlier studies of both low luminosity X-ray sources and LMXBs in globulars, suggest there should be significant numbers of CVs in globulars. Although they have been searched for without success in selected cluster X-ray source fields, systematic surveys are lacking and would constrain binary production and both stellar and dynamical evolution in globular clusters. We describe the beginnings of such a search, using narrow band H-alpha imaging, and the sensitivities it might achieve.
Vision-related problems among the workers engaged in jewellery manufacturing.
Salve, Urmi Ravindra
2015-01-01
American Optometric Association defines Computer Vision Syndrome (CVS) as "complex of eye and vision problems related to near work which are experienced during or related to computer use." This happens when visual demand of the tasks exceeds the visual ability of the users. Even though problems were initially attributed to computer-related activities subsequently similar problems are also reported while carrying any near point task. Jewellery manufacturing activities involves precision designs, setting the tiny metals and stones which requires high visual attention and mental concentration and are often near point task. It is therefore expected that the workers engaged in jewellery manufacturing may also experience symptoms like CVS. Keeping the above in mind, this study was taken up (1) To identify the prevalence of symptoms like CVS among the workers of the jewellery manufacturing and compare the same with the workers working at computer workstation and (2) To ascertain whether such symptoms have any permanent vision-related problems. Case control study. The study was carried out in Zaveri Bazaar region and at an IT-enabled organization in Mumbai. The study involved the identification of symptoms of CVS using a questionnaire of Eye Strain Journal, opthalmological check-ups and measurement of Spontaneous Eye Blink rate. The data obtained from the jewellery manufacturing was compared with the data of the subjects engaged in computer work and with the data available in the literature. A comparative inferential statistics was used. Results showed that visual demands of the task carried out in jewellery manufacturing were much higher than that of carried out in computer-related work.
New insights about cloud vertical structure from CloudSat and CALIPSO observations
NASA Astrophysics Data System (ADS)
Oreopoulos, Lazaros; Cho, Nayeong; Lee, Dongmin
2017-09-01
Active cloud observations from A-Train's CloudSat and CALIPSO satellites offer new opportunities to examine the vertical structure of hydrometeor layers. We use the 2B-CLDCLASS-LIDAR merged CloudSat-CALIPSO product to examine global aspects of hydrometeor vertical stratification. We group the data into major cloud vertical structure (CVS) classes based on our interpretation of how clouds in three standard atmospheric layers overlap and provide their global frequency of occurrence. The two most frequent CVS classes are single-layer (per our definition) low and high clouds that represent 53% of cloudy skies, followed by high clouds overlying low clouds, and vertically extensive clouds that occupy near-contiguously a large portion of the troposphere. The prevalence of these configurations changes seasonally and geographically, between daytime and nighttime, and between continents and oceans. The radiative effects of the CVS classes reveal the major radiative warmers and coolers from the perspective of the planet as a whole, the surface, and the atmosphere. Single-layer low clouds dominate planetary and atmospheric cooling and thermal infrared surface warming. We also investigate the consistency between passive and active views of clouds by providing the CVS breakdowns of Moderate Resolution Imaging Spectroradiometer cloud regimes for spatiotemporally coincident MODIS-Aqua (also on the A-Train) and CloudSat-CALIPSO daytime observations. When the analysis is expanded for a more in-depth look at the most heterogeneous of the MODIS cloud regimes, it ultimately confirms previous interpretations of their makeup that did not have the benefit of collocated active observations.
Warm-up effects from concomitant use of vibration and static stretching after cycling.
Yang, Wen-Wen; Liu, Chiang; Shiang, Tzyy-Yuang
2017-04-01
Static stretch is routinely used in traditional warm-up but impaired muscle performance. Combining vibration with static stretching as a feasible component may be an alternative to static stretching after submaximal aerobic exercise to improve jumping as well as flexibility. Therefore, the purpose of this study was to investigate and compare the effects of aerobic exercise, static stretching, and vibration with static stretching on flexibility and vertical jumping performance. A repeated measures experimental design was used in this study. Twelve participants randomly underwent 5 different warm-ups including cycling alone (C warm-up), static stretching alone (S warm-up), combining vibration with static stretching (VS warm-up), cycling followed by S (C+S warm-up), and cycling followed by VS (C+VS warm-up) on 5 separate days. Sit-and-reach, squat jump (SJ), and counter movement jump (CMJ) were measured for pre- and post- tests. The sit-and-reach scores after the S, VS, C+S and C+VS warm-ups were significantly enhanced (P<0.001), and were significantly greater than that of the C warm-up (P<0.05). The jumping height of SJ and CMJ after the C and C+VS warm-ups were significantly increased (P<0.05), whereas a significant reduction was found after the S warm-up (P<0.05). Vibration combined with stretching after submaximal cycling exercise (C+VS warm-up) could be a feasible warm-up protocol to improve both flexibility and vertical jump performance, compared with the traditional warm-up (C+S warm-up).
An Internet survey of marijuana and hot shower use in adults with cyclic vomiting syndrome (CVS).
Venkatesan, Thangam; Sengupta, Jyotirmoy; Lodhi, Atena; Schroeder, Abigail; Adams, Kathleen; Hogan, Walter J; Wang, Yanzhi; Andrews, Christopher; Storr, Martin
2014-08-01
Cyclic vomiting syndrome (CVS) is a chronic disorder characterized by episodic nausea and vomiting. A large proportion of patients use marijuana to control their symptoms. Several case reports implicate marijuana as a cause of intractable vomiting with compulsive hot water bathing considered pathognomonic of "cannabinoid hyperemesis." We sought to examine the relationship between marijuana use and CVS. Patients >18 years of age diagnosed by a health care provider were invited to participate in an anonymous internet-based survey. A total of 514 patients participated and 437 completed questions about marijuana use. Mean age was 34 ± 12 years with patients being predominantly female (63%), Caucasian (92%) and from the USA (82%). Nineteen percent never used marijuana and 81% did. Fifty-four percent used marijuana for health issues and 43% for recreational purposes. Users stated that it improved nausea, appetite, general well-being, stress levels and vomiting. Users were more likely to be male and have an associated anxiety disorder. Sixty-seven percent of patients reported taking hot showers/baths for symptom relief, and this was associated with marijuana use. (OR 2.54, CI 1.50-4.31, P = 0.0006). Eighty-one percent of patients with CVS who completed an internet survey reported frequent use of marijuana. With marijuana use, patients noted the greatest improvement with stress levels, appetite and nausea. Marijuana users were more likely to be male and have associated anxiety. Hot showers were not pathognomonic of marijuana use though they were more likely to be associated with its use.
NASA Technical Reports Server (NTRS)
Price, R.; Gady, S.; Heinemann, K.; Nelson, E. S.; Mulugeta, L.; Ethier, C. R.; Samuels, B. C.; Feola, A.; Vera, J.; Myers, J. G.
2015-01-01
A recognized side effect of prolonged microgravity exposure is visual impairment and intracranial pressure (VIIP) syndrome. The medical understanding of this phenomenon is at present preliminary, although it is hypothesized that the headward shift of bodily fluids in microgravity may be a contributor. Computational models can be used to provide insight into the origins of VIIP. In order to further investigate this phenomenon, NASAs Digital Astronaut Project (DAP) is developing an integrated computational model of the human body which is divided into the eye, the cerebrovascular system, and the cardiovascular system. This presentation will focus on the development and testing of the computational model of an integrated model of the cardiovascular system (CVS) and central nervous system (CNS) that simulates the behavior of pressures, volumes, and flows within these two physiological systems.
Barwegen, Martine
2008-01-01
The Civil Veterinary Service on Java, Netherlands East-Indies, was established in 1853, more than 20 years after the introduction of the Cultivation System. During the 19th century its tasks were directed at the survey of livestock, esp. its health. Despite the fact that the number of veterinarians was far from enough, the communications problematic, and the optimal functioning of the Service assailed by infrastructional shortcomings, the CVS managed to carry out--in a relatively short period--a great deal of significant work. The CVS sometimes misjudged the situation completely, e.g. after the outbreak of rinderpest in 1878, that was a major catastrophe. The Dutch laws pertaining to the fight against this diseases were enforced in the Netherlands East-Indies. Agriculture suffered from the ban on moving cattle, cattle suffered from a feed shortage and cattle owners suffered from financial and emotional damage. Although it is impossible to determine exactly the influence of the adopted measures on the course of the epizootic, there are indications that the damages were aggravated through governmental interference.
New Southern Cataclysmic Variables: Discoveries from MASTER-SAAO
NASA Astrophysics Data System (ADS)
Buckley, D. A. H.; Potter, S. B.; Kniazev, A.; Lipunov, V.; Gorbovskoy, E.; Tiurina, N.
2017-03-01
In this paper we report on new cataclysmic variables (CVs) discovered by the first local optical transient detection system established at the SAAO Sutherland station, namely MASTER-SAAO. The characteristics of the MASTER-SAAO system are described and the parameters of the survey compared to the Catalina Real Time Survey (CRTS). To date MASTER-SAAO has discovered over 200 (non-Solar System) optical transients with about 75% of these being likely new CVs, most being dwarf novae (DNe). Approximately 50% of the DNe have outburst amplitudes in excess of 4 magnitudes, with some extreme amplitude (> 7 mag), probable WZ Sge systems. The MASTER-SAAO detection limit of B = 19-20 is comparable to the ˜20 magnitude limit of the CRTS (depending on CV colour). Based on the CV detection statistics of CRTS, we believe that MASTER-SAAO is detecting essentially the same CV population as CRTS, for a detection outburst amplitude threshold >2.2 magnitudes. We also present results of the initial follow-up program on CVs discovered by MASTER, including dwarf novae, a bright new VY Scl system and a new eclipsing polar.
NASA Astrophysics Data System (ADS)
Kolb, Ulrich; Baraffe, Isabelle
Using improved, up-to-date stellar input physics tested against observations of low-mass stars and brown dwarfs we calculate the secular evolution of low-donor-mass CVs, including those which form with a brown dwarf donor star. Our models confirm the mismatch between the calculated minimum period (plus or minus in ~= 70 min) and the observed short-period cut-off (~= 80 min) in the CV period histogram. Theoretical period distributions synthesized from our model sequences always show an accumulation of systems at the minimum period, a feature absent in the observed distribution. We suggest that non-magnetic CVs become unobservable as they are effectively trapped in permanent quiescence before they reach plus or minus in, and that small-number statistics may hide the period spike for magnetic CVs. We calculate the minimum period for high mass transfer rate sequences and discuss the relevance of these for explaining the location of CV secondaries in the orbital-period-spectral-type diagram. We also show that a recently suggested revised mass-radius relation for low-mass main-sequence stars cannot explain the CV period gap.
X-Ray Emissions from Accreting White Dwarfs: A Review
NASA Technical Reports Server (NTRS)
Mukai, K.
2017-01-01
Interacting binaries in which a white dwarf accretes material from a companion-cataclysmic variables (CVs) in which the mass donor is a Roche-lobe filling star on or near the main sequence, and symbiotic stars in which the mass donor is a late type giant-are relatively commonplace. They display a wide range of behaviors in the optical, X-rays, and other wavelengths, which still often baffle observers and theorists alike. Here I review the existing body of research on X-ray emissions from these objects for the benefits of both experts and newcomers to the field. I provide introductions to the past and current X-ray observatories, the types of known X-ray emissions from these objects, and the data analysis techniques relevant to this field. I then summarize of our knowledge regarding the X-ray emissions from magnetic CVs, non-magnetic CVs and symbiotic stars, and novae in eruption. I also discuss space density and the X-ray luminosity functions of these binaries and their contribution to the integrated X-ray emission from the Galaxy. I then discuss open questions and future prospects.
A uniform input data convention for the CALL 3-D crash victim simulation
NASA Astrophysics Data System (ADS)
Shaibani, S. J.
1982-07-01
Logical schemes for the labelling of planes (cards D) and functions (cards E) in the input decks used for the Calspan 3-D Crash Victim Simulation (CVS) program are proposed. One benefit of introducing such a standardized format for these inputs would be to facilitate greatly the interchange of data for different vehicles. A further advantage would be that the table of allowed contacts (cards F) could remain largely unaltered. It is hoped that the uniformity of the convention described by these schemes would help to promote the exchange of readily usable data between CVS users.
Motoi, Yurie; Inoue, Satoshi; Hatta, Hajime; Sato, Kozue; Morimoto, Kinjiro; Yamada, Akio
2005-04-01
We obtained rabies-specific egg yolk antibodies (IgY) by immunizing hens with recombinant His-tagged nucleoprotein and phosphoprotein (rN, rP) of the rabies virus (CVS-11 strain) expressed in Escherichia coli. The anti-rN and rP IgY were shown to bind specifically to the respective proteins of the CVS-11 strain of rabies virus by Western blotting, immune fluorescent assay and immunohistochemistry, indicating that IgY to rabies recombinant proteins could serve as a reagent for diagnosis of rabies virus infection.
Martínez Vega, Mabel V; Sharifzadeh, Sara; Wulfsohn, Dvoralai; Skov, Thomas; Clemmensen, Line Harder; Toldam-Andersen, Torben B
2013-12-01
Visible-near infrared spectroscopy remains a method of increasing interest as a fast alternative for the evaluation of fruit quality. The success of the method is assumed to be achieved by using large sets of samples to produce robust calibration models. In this study we used representative samples of an early and a late season apple cultivar to evaluate model robustness (in terms of prediction ability and error) on the soluble solids content (SSC) and acidity prediction, in the wavelength range 400-1100 nm. A total of 196 middle-early season and 219 late season apples (Malus domestica Borkh.) cvs 'Aroma' and 'Holsteiner Cox' samples were used to construct spectral models for SSC and acidity. Partial least squares (PLS), ridge regression (RR) and elastic net (EN) models were used to build prediction models. Furthermore, we compared three sub-sample arrangements for forming training and test sets ('smooth fractionator', by date of measurement after harvest and random). Using the 'smooth fractionator' sampling method, fewer spectral bands (26) and elastic net resulted in improved performance for SSC models of 'Aroma' apples, with a coefficient of variation CVSSC = 13%. The model showed consistently low errors and bias (PLS/EN: R(2) cal = 0.60/0.60; SEC = 0.88/0.88°Brix; Biascal = 0.00/0.00; R(2) val = 0.33/0.44; SEP = 1.14/1.03; Biasval = 0.04/0.03). However, the prediction acidity and for SSC (CV = 5%) of the late cultivar 'Holsteiner Cox' produced inferior results as compared with 'Aroma'. It was possible to construct local SSC and acidity calibration models for early season apple cultivars with CVs of SSC and acidity around 10%. The overall model performance of these data sets also depend on the proper selection of training and test sets. The 'smooth fractionator' protocol provided an objective method for obtaining training and test sets that capture the existing variability of the fruit samples for construction of visible-NIR prediction models. The implication is that by using such 'efficient' sampling methods for obtaining an initial sample of fruit that represents the variability of the population and for sub-sampling to form training and test sets it should be possible to use relatively small sample sizes to develop spectral predictions of fruit quality. Using feature selection and elastic net appears to improve the SSC model performance in terms of R(2), RMSECV and RMSEP for 'Aroma' apples. © 2013 Society of Chemical Industry.
Reproducibility of CT Perfusion Parameters in Liver Tumors and Normal Liver
Ng, Chaan S.; Chandler, Adam G.; Wei, Wei; Herron, Delise H.; Anderson, Ella F.; Kurzrock, Razelle; Charnsangavej, Chusilp
2011-01-01
Purpose: To assess the reproducibility of computed tomographic (CT) perfusion measurements in liver tumors and normal liver and effects of motion and data acquisition time on parameters. Materials and Methods: Institutional review board approval and written informed consent were obtained for this prospective study. The study complied with HIPAA regulations. Two CT perfusion scans were obtained 2–7 days apart in seven patients with liver tumors with two scanning phases (phase 1: 30-second breath-hold cine; phase 2: six intermittent free-breathing cines) spanning 135 seconds. Blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability–surface area product (PS) for tumors and normal liver were calculated from phase 1 with and without rigid registration and, for combined phases 1 and 2, with manually and rigid-registered phase 2 images, by using deconvolution modeling. Variability was assessed with within-patient coefficients of variation (CVs) and Bland-Altman analyses. Results: For tumors, BF, BV, MTT, and PS values and reproducibility varied by analytical method, the former by up to 11%, 23%, 21%, and 138%, respectively. Median PS values doubled with the addition of phase 2 data to phase 1 data. The best overall reproducibility was obtained with rigidly registered phase 1 and phase 2 images, with within-patient CVs for BF, BV, MTT, and PS of 11.2%, 14.4%, 5.5% and 12.1%, respectively. Normal liver evaluations were similar, except with marginally lower variability. Conclusion: Absolute values and reproducibility of CT perfusion parameters were markedly influenced by motion and data acquisition time. PS, in particular, probably requires data acquisition beyond a single breath hold, for which motion-correction techniques are likely necessary. © RSNA, 2011 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11110331/-/DC1 PMID:21788525
Gao, Jin; Li, Jingjing; Yang, Minmin; Wu, Mingyuan; Tu, Ping; Yu, Yan; Han, Wei
2015-01-01
To determine the incidence of the positive neutralizing anti-human interleukin receptor antagonist (anti-IL-1Ra), a novel assay based on the proliferation of human melanoma A375.S2 cells was developed and validated. In the presence of a growth-limiting concentration of IL-1β, A375.S2 cells were able to regain proliferation following the addition of IL-1Ra in a concentration-dependent manner. This dose-response effect enabled the validation of a standard curve for calculation of the concentration of IL-1Ra or, inversely, the concentration of neutralizing anti-IL-1Ra antibodies in cell culture medium or sera. The assay used CCK-8 as an indicator of proliferation. The dose-response relationship between rhIL-1Ra (dose range of 5-75 ng/ml rhIL-1Ra) and A375.S2 cell proliferation was sigmoidal and fitted a four-parameter logistic model. The percent coefficients of variation (%CVs) of quality control samples were 12.5 and 11.9% for intra-assay repeatability and 14.5 and 19.5% for inter-assay repeatability, while the total accuracy was in the range of 97.2-103.6%. For the neutralization assay, the optimal sample dilution factor was found to be 40-fold and the reasonable standard for positive and negative decision was calculated to be 59.4% neutralization rate. The %CVs of quality control samples were 12.7 and 24.0% for intra-assay repeatability and 11.6 and 30.0% for inter-assay repeatability. Analysis using the assay showed that rats could produce neutralizing anti-IL-1Ra antibodies after repeated intramuscular injection with rhIL-1Ra, and this response was not significantly dependent on the dose injected.
Implementation of maternal blood cell-free DNA testing in early screening for aneuploidies.
Gil, M M; Quezada, M S; Bregant, B; Ferraro, M; Nicolaides, K H
2013-07-01
To explore the feasibility of routine maternal blood cell-free (cf) DNA testing in screening for trisomies 21, 18 and 13 at 10 weeks' gestation. In this prospective study, women attending The Fetal Medicine Centre in London, UK, between October 2012 and April 2013, with singleton pregnancy and live fetus with CRL 32-45 mm, were screened for trisomies 21, 18 and 13 by cfDNA testing at 10 weeks and the combined test at 12 weeks. cfDNA testing was performed in 1005 singleton pregnancies with a median maternal age of 37 (range, 20-49) years. Risks for trisomies were provided for 957 (95.2%) cases and in 98.0% these were available within 14 days from sampling. In 48 (4.8%) cases no result was provided due to problems with delivery to the laboratory, low fetal fraction or assay failure. Repeat sampling was performed in 40 cases and a result obtained in 27 (67.5%) of these. In 11 cases the risk score for trisomy 21 and in five cases that for trisomy 18 was > 99%, in one the risk for trisomy 13 was 34% and in 968 the risk for each of the three trisomies was < 0.01%. The suspected trisomies were confirmed by karyotyping after chorionic villus sampling (CVS), except in one case of trisomy 18 in which the karyotype was normal. On the basis of the maternal age distribution of the study population, the expected and observed numbers for each of the three trisomies were similar. Both cfDNA and combined testing detected all trisomies, but the estimated false-positive rates (FPR) were 0.1% and 3.4%, respectively. Routine screening for trisomies 21, 18 and 13 by cfDNA testing at 10 weeks is feasible and has a lower FPR than does combined testing, but abnormal results require confirmation by CVS. Copyright © 2013 ISUOG. Published by John Wiley & Sons, Ltd.
Verification of Abbott 25-OH-vitamin D assay on the architect system.
Hutchinson, Katrina; Healy, Martin; Crowley, Vivion; Louw, Michael; Rochev, Yury
2017-04-01
Analytical and clinical verification of both old and new generations of the Abbott total 25-hydroxyvitamin D (25OHD) assays, and an examination of reference Intervals. Determination of between-run precision, and Deming comparison between patient sample results for 25OHD on the Abbott Architect, DiaSorin Liaison and AB SCIEX API 4000 (LC-MS/MS). Establishment of uncertainty of measurement for 25OHD Architect methods using old and new generations of the reagents, and estimation of reference interval in healthy Irish population. For between-run precision the manufacturer claims 2.8% coefficients of variation (CVs) of 2.8% and 4.6% for their high and low controls, respectively. Our instrument showed CVs between 4% and 6.2% for all levels of the controls on both generations of the Abbott reagents. The between-run uncertainties were 0.28 and 0.36, with expanded uncertainties 0.87 and 0.98 for the old and the new generations of reagent, respectively. The difference between all methods used for patients' samples was within total allowable error, and the instruments produced clinically equivalent results. The results covered the medical decision points of 30, 40, 50 and 125 nmol/L. The reference interval for total 25OHD in our healthy Irish subjects was lower than recommended levels (24-111 nmol/L). In a clinical laboratory Abbott 25OHD immunoassays are a useful, rapid and accurate method for measuring total 25OHD. The new generation of the assay was confirmed to be reliable, accurate, and a good indicator for 25OHD measurement. More study is needed to establish reference intervals that correctly represent the healthy population in Ireland.
Comparison of Wipe Materials and Wetting Agents for Pesticide Residue Collection from Hard Surfaces
Deziel, Nicole C.; Viet, Susan M.; Rogers, John W.; Camann, David E.; Marker, David A.; Heikkinen, Maire S. A.; Yau, Alice Y.; Stout, Daniel M.; Dellarco, Michael
2011-01-01
Different wipe materials and wetting agents have been used to collect pesticide residues from surfaces, but little is known about their comparability. To inform the selection of a wipe for the National Children’s Study, the analytical feasibility, collection efficiency, and precision of Twillwipes wetted with isopropanol (TI), Ghost Wipes (GW), and Twillwipes wetted with water (TW), and were evaluated. Wipe samples were collected from stainless steel surfaces spiked with high and low concentrations of 27 insecticides, including organochlorines, organophosphates, and pyrethroids. Samples were analyzed by GC/MS/SIM. No analytical interferences were observed for any of the wipes. The mean percent collection efficiencies across all pesticides for the TI, GW, and TW were 69.3%, 31.1%, and 10.3% at the high concentration, respectively, and 55.6%, 22.5%, and 6.9% at the low concentration, respectively. The collection efficiencies of the TI were significantly greater than that of GW or TW (p<0.0001). Collection efficiency also differed significantly by pesticide (p<0.0001) and spike concentration (p<0.0001). The pooled coefficients of variation (CVs) of the collection efficiencies for the TI, GW, and TW at high concentration were 0.08, 0.17, and 0.24, respectively. The pooled CV of the collection efficiencies for the TI, GW, and TW at low concentration were 0.15, 0.19, and 0.36, respectively. The TI had significantly lower CVs than either of the other two wipes (p=0.0008). Though the TI was superior in terms of both accuracy and precision, it requires multiple preparation steps, which could lead to operational challenges in a large-scale study. PMID:21816452
NASA Astrophysics Data System (ADS)
Piasecki, M.; Ji, P.
2014-12-01
Geoscience data comes in many flavors that are determined by type of data such as continous on a grid or mesh or discrete colelcted at point either as one time samples or a stream of data coming of sensors, but coudl also encompass digital files of any time type such text files, WORD or EXCEL documents, or audio and video files. We present a storage facility that is comprsed of 6 nodes each of speciaized to host a certain data type: grid based data (netCDF on a THREDDS server), GIS data (shapefiles using GeoServer), point time series data (CUAHSI ODM), sample data (EDBS), and any digital data (RAMADAA) plus a server fro Remote sensing data and its products. While there is overlap in data type storage capabilities (rasters can go into several of these nodes) we prefer to use dedicated storage facilities that are a) freeware, and b) have a good degree of maturity, and c) have shown their utility for stroing a cetain type. In addition it allows to place these commonly used software stacks and storage solutiosn side-by-side to develop interoprability strategies. We have used a DRUPAL based system to handle user regoistration and authentication, and also use the system for data submission and data search. In support for tis system we developed an extensive controlled vocabulary system that is an amalgamation of various CVs used in the geosciecne community in order to achieve as high a degree of recognition, such the CF conventions, CUAHSI Cvs, , NASA (GCMD), EPA and USGS taxonomies, GEMET, in addition to ontological representations such as SWEET.
New, small, fast acting blood glucose meters--an analytical laboratory evaluation.
Weitgasser, Raimund; Hofmann, Manuela; Gappmayer, Brigitta; Garstenauer, Christa
2007-09-22
Patients and medical personnel are eager to use blood glucose meters that are easy to handle and fast acting. We questioned whether accuracy and precision of these new, small and light weight devices would meet analytical laboratory standards and tested four meters with the above mentioned conditions. Approximately 300 capillary blood samples were collected and tested using two devices of each brand and two different types of glucose test strips. Blood from the same samples was used for comparison. Results were evaluated using maximum deviation of 5% and 10% from the comparative method, the error grid analysis, the overall deviation of the devices, the linear regression analysis as well as the CVs for measurement in series. Of all 1196 measurements a deviation of less than 5% resp. 10% from the reference method was found for the FreeStyle (FS) meter in 69.5% and 96%, the Glucocard X Meter (GX) in 44% and 75%, the One Touch Ultra (OT) in 29% and 60%, the Wellion True Track (WT) in 28.5% and 58%. The error grid analysis gave 99.7% for FS, 99% for GX, 98% for OT and 97% for WT in zone A. The remainder of the values lay within zone B. Linear regression analysis resembled these results. CVs for measurement in series showed higher deviations for OT and WT compared to FS and GX. The four new, small and fast acting glucose meters fulfil clinically relevant analytical laboratory requirements making them appropriate for use by medical personnel. However, with regard to the tight and restrictive limits of the ADA recommendations, the devices are still in need of improvement. This should be taken into account when the devices are used by primarily inexperienced persons and is relevant for further industrial development of such devices.
Poon, Anna K; Meyer, Michelle L; Reaven, Gerald; Knowles, Joshua W; Selvin, Elizabeth; Pankow, James S; Couper, David; Loehr, Laura; Heiss, Gerardo
2018-06-01
The homeostatic model assessment of insulin resistance (HOMA-IR) and triglyceride (TG)/high-density lipoprotein cholesterol (HDL-C) ratio (TG/HDL-C) are insulin resistance indexes routinely used in clinical and population-based studies; however, their short-term repeatability is not well characterized. To quantify the short-term repeatability of insulin resistance indexes and their analytes, consisting of fasting glucose and insulin for HOMA-IR and TG and HDL-C for TG/HDL-C. Prospective cohort study. A total of 102 adults 68 to 88 years old without diabetes attended an initial examination and repeated examination (mean, 46 days; range, 28 to 102 days). Blood samples were collected, processed, shipped, and assayed following a standardized protocol. Repeatability was quantified using the intraclass correlation coefficient (ICC) and within-person coefficient of variation (CV). Minimum detectable change (MDC95) and minimum detectable difference with 95% confidence (MDD95) were quantified. For HOMA-IR, insulin, and fasting glucose, the ICCs were 0.70, 0.68, and 0.70, respectively; their respective within-person CVs were 30.4%, 28.8%, and 5.6%. For TG/HDL-C, TG, and HDL-C, the ICCs were 0.80, 0.68, and 0.91, respectively; their respective within-person CVs were 23.0%, 20.6%, and 8.2%. The MDC95 was 2.3 for HOMA-IR and 1.4 for TG/HDL-C. The MDD95 for a sample of n = 100 was 0.8 for HOMA-IR and 0.6 for TG/HDL-C. Short-term repeatability was fair to good for HOMA-IR and excellent for TG/HDL-C according to suggested benchmarks, reflecting the short-term variability of their analytes. These measurement properties can inform the use of these indexes in clinical and population-based studies.
Ladwig, R; Vigo, A; Fedeli, L M G; Chambless, L E; Bensenor, I; Schmidt, M I; Vidigal, P G; Castilhos, C D; Duncan, B B
2016-08-01
Multi-center epidemiological studies must ascertain that their measurements are accurate and reliable. For laboratory measurements, reliability can be assessed through investigation of reproducibility of measurements in the same individual. In this paper, we present results from the quality control analysis of the baseline laboratory measurements from the ELSA-Brasil study. The study enrolled 15,105 civil servants at 6 research centers in 3 regions of Brazil between 2008-2010, with multiple biochemical analytes being measured at a central laboratory. Quality control was ascertained through standard laboratory evaluation of intra- and inter-assay variability and test-retest analysis in a subset of randomly chosen participants. An additional sample of urine or blood was collected from these participants, and these samples were handled in the same manner as the original ones, locally and at the central laboratory. Reliability was assessed with the intraclass correlation coefficient (ICC), estimated through a random effects model. Coefficients of variation (CV) and Bland-Altman plots were additionally used to assess measurement variability. Laboratory intra and inter-assay CVs varied from 0.86% to 7.77%. From test-retest analyses, the ICCs were high for the majority of the analytes. Notably lower ICCs were observed for serum sodium (ICC=0.50; 95%CI=0.31-0.65) and serum potassium (ICC=0.73; 95%CI=0.60-0.83), due to the small biological range of these analytes. The CVs ranged from 1 to 14%. The Bland-Altman plots confirmed these results. The quality control analyses showed that the collection, processing and measurement protocols utilized in the ELSA-Brasil produced reliable biochemical measurements.
Li, Tingting; Wang, Wei; Zhao, Haijian; He, Falin; Zhong, Kun; Yuan, Shuai; Wang, Zhiguo
2017-09-07
This study aimed to investigate the status of internal quality control (IQC) for cardiac biomarkers from 2011 to 2016 so that we can have overall knowledge of the precision level of measurements in China and set appropriate precision specifications. Internal quality control data of cardiac biomarkers, including creatinine kinase MB (CK-MB) (μg/L), CK-MB(U/L), myoglobin (Mb), cardiac troponin I (cTnI), cardiac troponin T (cTnT), and homocysteines (HCY), were collected by a web-based external quality assessment (EQA) system. Percentages of laboratories meeting five precision quality specifications for current coefficient of variations (CVs) were calculated. Then, appropriate precision specifications were chosen for these six analytes. Finally, the CVs and IQC practice were further analyzed with different grouping methods. The current CVs remained nearly constant for 6 years. cTnT had the highest pass rates every year against five specifications, whereas HCY had the lowest pass rates. Overall, most analytes had a satisfactory performance (pass rates >80%), except for HCY, if one-third TEa or the minimum specification were employed. When the optimal specification was applied, the performance of most analytes was frustrating (pass rates < 60%) except for cTnT. The appropriate precision specifications of Mb, cTnI, cTnT and HCY were set as current CVs less than 9.20%, 9.90%, 7.50%, 10.54%, 7.63%, and 6.67%, respectively. The data of IQC practices indicated wide variation and substantial progress. The precision performance of cTnT was already satisfying, while the other five analytes, especially HCY, were still frustrating; thus, ongoing investigation and continuous improvement for IQC are still needed. © 2017 Wiley Periodicals, Inc.
Bundzikova-Osacka, Jana; Ghosal, Sriparna; Packard, Benjamin A; Ulrich-Lai, Yvonne M; Herman, James P
2015-01-01
Chronic stress causes hypothalamo-pituitary-adrenal (HPA) axis hyperactivity and cardiovascular dyshomeostasis. Noradrenergic (NA) neurons in the nucleus of the solitary tract (NTS) are considered to play a role in these changes. In this study, we tested the hypothesis that NTS NA A2 neurons are required for cardiovascular and HPA axis responses to both acute and chronic stress. Adult male rats received bilateral microinjection into the NTS of 6-hydroxydopamine (6-OHDA) to lesion A2 neurons [cardiovascular study, n = 5; HPA study, n = 5] or vehicle [cardiovascular study, n = 6; HPA study, n = 4]. Rats were exposed to acute restraint stress followed by 14 d of chronic variable stress (CVS). On the last day of testing, rats were placed in a novel elevated plus maze (EPM) to test post-CVS stress responses. Lesions of NTS A2 neurons reduced the tachycardic response to acute restraint, confirming that A2 neurons promote sympathetic activation following acute stress. In addition, CVS increased the ratio of low-frequency to high-frequency power for heart rate variability, indicative of sympathovagal imbalance, and this effect was significantly attenuated by 6-OHDA lesion. Lesions of NTS A2 neurons reduced acute restraint-induced corticosterone secretion, but did not affect the corticosterone response to the EPM, indicating that A2 neurons promote acute HPA axis responses, but are not involved in CVS-mediated HPA axis sensitization. Collectively, these data indicate that A2 neurons promote both cardiovascular and HPA axis responses to acute stress. Moreover, A2 catecholaminergic neurons may contribute to the potentially deleterious enhancement of sympathetic drive following chronic stress.
Koeslin-Findeklee, Fabian; Becker, Martin A.; van der Graaff, Eric; Roitsch, Thomas; Horst, Walter J.
2015-01-01
Nitrogen (N) efficiency of winter oilseed rape (Brassica napus L.) line-cultivars (cvs.), defined as high grain yield under N limitation, has been primarily attributed to maintained N uptake during reproductive growth (N uptake efficiency) in combination with delayed senescence of the older leaves accompanied with maintained photosynthetic capacity (functional stay-green). However, it is not clear whether genotypic variation in N starvation-induced leaf senescence is due to leaf-inherent factors and/or governed by root-mediated signals. Therefore, the N-efficient and stay-green cvs. NPZ-1 and Apex were reciprocally grafted with the N-inefficient and early-senescing cvs. NPZ-2 and Capitol, respectively and grown in hydroponics. The senescence status of older leaves after 12 days of N starvation assessed by SPAD, photosynthesis and the expression of the senescence-specific cysteine protease gene SAG12-1 revealed that the stay-green phenotype of the cvs. NPZ-1 and Apex under N starvation was primarily under the control of leaf-inherent factors. The same four cultivars were submitted to N starvation for up to 12 days in a time-course experiment. The specific leaf contents of biologically active and inactive cytokinins (CKs) and the expression of genes involved in CK homeostasis revealed that under N starvation leaves of early-senescing cultivars were characterized by inactivation of biologically active CKs, whereas in stay-green cultivars synthesis, activation, binding of and response to biologically active CKs were favoured. These results suggest that the homeostasis of biologically active CKs was the predominant leaf-inherent factor for cultivar differences in N starvation-induced leaf senescence and thus N efficiency. PMID:25944925
House, James R; Lunt, Heather C; Taylor, Rowan; Milligan, Gemma; Lyons, Jason A; House, Carol M
2013-05-01
Cooling vests (CV) are often used to reduce heat strain. CVs have traditionally used ice as the coolant, although other phase-change materials (PCM) that melt at warmer temperatures have been used in an attempt to enhance cooling by avoiding vasoconstriction, which supposedly occurs when ice CVs are used. This study assessed the effectiveness of four CVs that melted at 0, 10, 20 and 30 °C (CV₀, CV₁₀, CV₂₀, and CV₃₀) when worn by 10 male volunteers exercising and then recovering in 40 °C air whilst wearing fire-fighting clothing. When compared with a non-cooling control condition (CON), only the CV₀ and CV₁₀ vests provided cooling during exercise (40 and 29 W, respectively), whereas all CVs provided cooling during resting recovery (CV₀ 69 W, CV₁₀ 66 W, CV₂₀ 55 W and CV₃₀ 29 W) (P < 0.05). In all conditions, skin blood flow increased when exercising and reduced during recovery, but was lower in the CV₀ and CV₁₀ conditions compared with control during exercise (observed power 0.709) (P < 0.05), but not during resting recovery (observed power only 0.55). The participants preferred the CV₁₀ to the CV₀, which caused temporary erythema to underlying skin, although this resolved overnight after each occurrence. Consequently, a cooling vest melting at 10 °C would seem to be the most appropriate choice for cooling during combined work and rest periods, although possibly an ice-vest (CV₀) may also be appropriate if more insulation was worn between the cooling packs and the skin than used in this study.
Li, Tingting; Wang, Wei; Zhao, Haijian; He, Falin; Zhong, Kun; Yuan, Shuai; Wang, Zhiguo
2017-09-01
This study aimed to evaluate whether the quality performance of clinical laboratories in China has been greatly improved and whether Internal Quality Control (IQC) practice of HbA1c has also been changed since National Center for Clinical Laboratories (NCCL) of China organized laboratories to report IQC data for HbA1c in 2012. Internal Quality Control information of 306 External Quality Assessment (EQA) participant laboratories which kept reporting IQC data in February from 2012 to 2016 were collected by Web-based EQA system. Then percentages of laboratories meeting four different imprecision specifications for current coefficient of variations (CVs) of HbA1c measurements were calculated. Finally, we comprehensively analyzed analytical systems and IQC practice of HbA1c measurements. The current CVs of HbA1c tests have decreased significantly from 2012 to 2016. And percentages of laboratories meeting four imprecision specifications for CVs all showed the increasing tendency year by year. As for analytical system, 52.1% (159/306) laboratories changed their systems with the change in principle of assay. And many laboratories began to use cation exchange high-performance liquid chromatography (CE-HPLC) instead of Immunoturbidimetry, because CE-HPLC owed a lower intra-laboratory CVs. The data of IQC practice, such as IQC rules and frequency, also showed significant variability among years with overall tendency of meeting requirements. The imprecision performance of HbA1c tests has been improved in these 5 years with the change in IQC practice, but it is still disappointing in China. Therefore, laboratories should actively find existing problems and take action to promote performance of HbA1c measurements. © 2016 Wiley Periodicals, Inc.
Bundzikova-Osacka, Jana; Ghosal, Sriparna; Packard, Benjamin A.; Ulrich-Lai, Yvonne M.; Herman, James P.
2015-01-01
Chronic stress causes hypothalamo-pituitary-adrenal (HPA) axis hyperactivity and cardiovascular dyshomeostasis. Noradrenergic neurons in the nucleus of the solitary tract (NTS) are considered to play a role in these changes. Here, we tested the hypothesis that NTS noradrenergic A2 neurons are required for cardiovascular and HPA axis responses to both acute and chronic stress. Adult male rats received bilateral microinjection into the NTS of 6-hydroxydopamine (6-OHDA) to lesion A2 neurons [cardiovascular study, n= 5; HPA study, n= 5], or vehicle [cardiovascular study, n= 6; HPA study, n= 4]. Rats were exposed to acute restraint stress followed by 14 days of chronic variable stress (CVS). On the last day of testing, rats were placed in a novel elevated plus maze (EPM) to test post-CVS stress responses. Lesions of NTS A2 neurons reduced the tachycardic response to acute restraint, confirming that A2 neurons promote sympathetic activation following acute stress. In addition, CVS increased the ratio of low frequency to high frequency power for heart rate variability, indicative of sympathovagal imbalance, and this effect was significantly attenuated by 6-OHDA lesion. Lesions of NTS A2 neurons reduced acute restraint-induced corticosterone secretion, but did not affect the corticosterone response to the EPM, indicating that A2 neurons promote acute HPA axis responses, but are not involved in CVS-mediated HPA axis sensitization. Collectively, these data indicate that A2 neurons promote both cardiovascular and HPA axis responses to acute stress. Moreover, A2 catecholaminergic neurons may contribute to the potentially deleterious enhancement of sympathetic drive following chronic stress. PMID:25765732
Lu, Louis; Yip, Benjamin; Trinh, Huy; Pan, Calvin Q.; Han, Steven-Huy B.; Wong, Christopher C.; Li, Jiayi; Chan, Stanley; Krishnan, Gomathi; Wong, Clifford C.; Nguyen, Mindie H.
2014-01-01
Entecavir (ETV) is a first-line antiviral therapy for treating chronic hepatitis B (CHB); however, some patients have suboptimal response to ETV. Currently, there are limited data on how to approach these patients. Therefore our aim was to compare the effectiveness of two alternate therapies – tenofovir (TDF) monotherapy and combination therapy of ETV+TDF – in CHB patients with ETV partial virological response. We conducted a retrospective study of 68 patients who had partial virological response to ETV, defined as having detectable HBV DNA following at least 12 months of ETV, and were switched to TDF monotherapy (n=25) or ETV+TDF (n=43). Patients were seen in 7 US liver/community-based clinics and started on ETV between 2005-2009. The majority of patients were male; the vast majority were Asian and had positive hepatitis B e antigen (HBeAg). Patients in both groups had similar pre-treatment characteristics. Complete viral suppression (CVS) rates with TDF monotherapy and ETV+TDF were similar after 6 months (71% vs. 83, p=0.23) and 12 months (86% vs. 84%, p=0.85), and there was no statistically significant difference in CVS rates even when only patients with higher HBV DNA levels at switch (>1,000 IU/mL) were evaluated. Multivariate analysis indicated that ETV+TDF was not an independent predictor of CVS compared to TDF monotherapy (OR=1.19, p=0.63). In conclusion, TDF monotherapy and ETV+TDF are comparable in achieving CVS in CHB patients with partial virological response to ETV. Long-term alternate therapy with one pill (TDF monotherapy) vs. two pills (ETV+TDF) could lead to lower non-adherence rates and better treatment outcomes. PMID:25417914
Morris, Joan K; Waters, Jonathan J; de Souza, E
2012-06-01
Pregnant women who receive a high screening risk result for Down, Edwards or Patau syndrome are offered diagnostic tests that carry a risk of miscarriage. This study determined how many women had such tests per syndrome diagnosis. The number of tests per Down, Edwards or Patau syndrome diagnosis adjusted for maternal and gestational age at diagnosis was calculated using routine data from 18 (95%) cytogenetic laboratories in England and Wales in 2008. There were 19,326 tests that identified 1118 diagnoses of Down syndrome and 615 of Edwards and Patau syndromes. There were eight chorionic villus samplings (CVS) per syndrome diagnosis compared with 16 amniocenteses (gestational age adjusted). The lowest number of tests per diagnosis (three for CVSs and for amniocentesis) resulted from an abnormal ultrasound scan. Among pregnant women, 2.9% had an invasive diagnostic test. If a CVS and an amniocentesis increase the risk of a miscarriage by 1% and 0.5%, respectively, approximately one miscarriage for every 14 Down, Edwards or Patau syndrome diagnosis would have occurred. A simple measurement of the population impact of screening for Down syndrome can be calculated using data already collected. Annual estimates should be produced to monitor the national fetal anomaly screening programme. © 2012 John Wiley & Sons, Ltd. © 2012 John Wiley & Sons, Ltd.
Lee, Wonmok; Ha, Jung-Sook; Ryoo, Nam-Hee
2016-09-01
The cobas u 701, a new automated image-based urine sediment analyzer, was introduced recently. In this study, we compared its performance with that of UF-1000i flow cytometry and manual microscopy in the examination of urine sediments. Precision, linearity, and carry-over were determined for the two urine sediment analyzers. For a comparison of the method, 300 urine samples were examined by the automated analyzers and by manual microscopy using a KOVA chamber. Within-run coefficients of variation (CVs) for the control materials were 7.0-8.8% and 1.7-5.7% for the cobas u 701 and UF-1000i systems, respectively. Between-run CVs were 8.5-9.8% and 2.7-5.4%, respectively. Both instruments showed good linearity and negligible carry-over. For red blood cells (RBC), white blood cells (WBC), and epithelial cells (EPI), the overall concordance rates within one grade of difference among the three methods were good (78.6-86.0%, 88.7-93.8%, and 81.3-90.7%, respectively). The concordance rate for casts was poor (66.5-68.9%). Compared with manual microscopy, the two automated sediment analyzers tested in this study showed satisfactory analytical performances for RBC, WBC, and EPI. However, for other urine sediment particles confirmation by visual microscopy is still required. © 2016 Wiley Periodicals, Inc.
Variability of soccer referees' match performances.
Weston, M; Drust, B; Atkinson, G; Gregson, W
2011-03-01
The aim of the present study was to determine the between-match variability in soccer referees' match performances. 1 269 individual match observations were undertaken on 59 referees (range 2-79 games per referee) officiating in the English Premier League and Championship from 2003/2004 to 2007/2008 using a computerised tracking system (Prozone (®), Leeds, England). Between-match coefficients of variation (CV) were calculated for all games and then compared between referee age and experience groups. High mean CVs were observed for high-speed running distance (25.9±10.1%), recovery time (32.7±13.8%), explosive sprints (34.3±16.6%), total number of sprints (54.0±20.7%) and number of match fouls (28±4.6%). Smaller CVs were observed for total distance covered (3.8±1.5%), top sprinting speed (5.6±10.9%), distance from the ball (4.2±1.9%) and the distance from fouls (9.9±4.3%). Variability in match activities was not influenced by referee age or experience. The present study's findings demonstrate that variability in soccer referees' match performances is high in some variables and not dependent on referee age or experience. Such variability means that research requires large sample sizes to detect real systematic changes in a number of performance characteristics when studied during matches. © Georg Thieme Verlag KG Stuttgart · New York.
Olawoyin, Richard; Schweitzer, Linda; Zhang, Kuangyuan; Okareh, Oladapo; Slates, Kevin
2018-02-01
The impacts of air emissions as a consequence of industrial activities around communities of human habitation have been extensively reported. This study is the first to assess potential adverse human health effects in the Chemical Valley Sarnia (CVS) area, around the St. Clair River, using health risk models, ecological and pollution indices. Large quantities of particulate matters (PM) are generated from anthropogenic activities, which contain several heavy metals in trace quantities with potentially adverse effects to humans and environmental health. The distribution, and human health impact assessment of trace element concentrations in PM fractions were examined. Elemental concentrations of As, Cd, Cr (VI), Cu, Fe, Mn, Pb, Ni, Zn were determined in the PM size-segregated samples collected from the CVS area between 2014 and 2017. The results showed relatively high concentration of PM <2.5 (87.19±8.1(mgm 3 )) which is approximately 4 times the WHO air quality guidelines. Pb concentration (143.03 ± 46.87ηg/m 3 ) was 3.6 times higher than the air quality standards of NAAQS. Cr (VI) showed moderate to considerable contamination ( C f =4) in the CVS while Cr (VI), Pb, and Ni had enrichment factor E f < 3 (minimal), signifying contributions from anthropogenic activities. Pollution load index (P Li ) value observed was 1.4 indicating human health risk from the PM, especially for the children in the area. The deposition fluxes (DΦ) showed that PM-bound metals could potentially bypass the head airways and cause damages to the tracheobronchial tree, increasing the human health risks of nephroblastomasis development. The main route of entry for the heavy metal bound PM in humans were observed as through ingestion and inhalation. The highest total excess cancer risks observed for children (6.7×10 -4 ) and adult (1.0×10 -4 ) indicating potential cancer effects. The Incremental Lifetime Cancer Risk (ILCR) increased from Pb < Ni < Cd < Cr (VI) < As. Overall, children are more likely to develop carcinogenic and non-carcinogenic health effects from exposures to elemental concentrations of airborne PM in the study area. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Lamer, K.; Fridlind, A. M.; Luke, E. P.; Tselioudis, G.; Ackerman, A. S.; Kollias, P.; Clothiaux, E. E.
2016-12-01
The presence of supercooled liquid in clouds affects surface radiative and hydrological budgets, especially at high latitudes. Capturing these effects is crucial to properly quantifying climate sensitivity. Currently, a number of CGMs disagree on the distribution of cloud phase. Adding to the challenge is a general lack of observations on the continuum of clouds, from high to low-level and from warm to cold. In the current study, continuous observations from 2011 to 2014 are used to evaluate all clouds produced by the GISS ModelE GCM over the ARM North Slope of Alaska site. The International Satellite Cloud Climatology Project (ISCCP) Global Weather State (GWS) approach reveals that fair-weather (GWS 7, 32% occurrence rate), as well as mid-level storm related (GWS 5, 28%) and polar (GWS 4, 14%) clouds, dominate the large-scale cloud patterns at this high latitude site. At higher spatial and temporal resolutions, ground-based cloud radar observations reveal a majority of single layer cloud vertical structures (CVS). While clear sky and low-level clouds dominate (each with 30% occurrence rate) a fair amount of shallow ( 10%) to deep ( 5%) convection are observed. Cloud radar Doppler spectra are used along with depolarization lidar observations in a neural network approach to detect the presence, layering and inhomogeneity of supercooled liquid layers. Preliminary analyses indicate that most of the low-level clouds sampled contain one or more supercooled liquid layers. Furthermore, the relationship between CVS and the presence of supercooled liquid is established, as is the relationship between the presence of supercool liquid and precipitation susceptibility. Two approaches are explored to bridge the gap between large footprint GCM simulations and high-resolution ground-based observations. The first approach consists of comparing model output and ground-based observations that exhibit the same column CVS type (i.e. same cloud depth, height and layering). Alternatively, the second approach consists of comparing model output and ground-based observations that exhibit the same large-scale GWS type (i.e. same cloud top pressure and optical depth patterns) where ground-based observations are associated to large-scale GWS every 3 hours using the closest satellite overpass.
NASA Astrophysics Data System (ADS)
Kim, Youngseob; Sartelet, Karine; Seigneur, Christian; Charron, Aurélie; Besombes, Jean-Luc; Jaffrezo, Jean-Luc; Marchand, Nicolas; Polo, Lucie
2016-09-01
Exhaust emissions of semi-volatile organic compounds (SVOC) from passenger vehicles are usually estimated only for the particle phase via the total particulate matter measurements. However, they also need to be estimated for the gas phase, as they are semi-volatile. To better estimate SVOC emission factors of passenger vehicles, a measurement campaign using a chassis dynamometer was conducted with different instruments: (1) a constant volume sampling (CVS) system in which emissions were diluted with filtered air and sampling was performed on filters and polyurethane foams (PUF) and (2) a Dekati Fine Particle Sampler (FPS) in which emissions were diluted with purified air and sampled with on-line instruments (PTR-ToF-MS, HR-ToF-AMS, MAAP, CPC). Significant differences in the concentrations of organic carbon (OC) measured by the instruments are observed. The differences can be explained by sampling artefacts, differences between (1) the time elapsed during sampling (in the case of filter and PUF sampling) and (2) the time elapsed from emission to measurement (in the case of on-line instruments), which vary from a few seconds to 15 min, and by the different dilution factors. To relate elapsed times and measured concentrations of OC, the condensation of SVOC between the gas and particle phases is simulated with a dynamic aerosol model. The simulation results allow us to understand the relation between elapsed times and concentrations in the gas and particle phases. They indicate that the characteristic times to reach thermodynamic equilibrium between gas and particle phases may be as long as 8 min. Therefore, if the elapsed time is less than this characteristic time to reach equilibrium, gas-phase SVOC are not at equilibrium with the particle phase and a larger fraction of emitted SVOC will be in the gas phase than estimated by equilibrium theory, leading to an underestimation of emitted OC if only the particle phase is considered or if the gas-phase SVOC are estimated by equilibrium theory. Current European emission inventories for passenger cars do not yet estimate gas-phase SVOC emissions, although they may represent 60% of total emitted SVOC (gas + particle phases).
Documentation of quality improvement exposure by internal medicine residency applicants.
Kolade, Victor O; Sethi, Anuradha
2016-01-01
Quality improvement (QI) has become an essential component of medical care in the United States. In residency programs, QI is a focus area of the Clinical Learning Environment Review visits conducted by the Accreditation Council for Graduate Medical Education. The readiness of applicants to internal medicine residency to engage in QI on day one is unknown. To document the reporting of QI training or experience in residency applications. Electronic Residency Application Service applications to a single internal medicine program were reviewed individually looking for reported QI involvement or actual projects in the curriculum vitae (CVs), personal statements (PSs), and letters of recommendation (LORs). CVs were also reviewed for evidence of education in QI such as completion of Institute for Healthcare Improvement (IHI) modules. Of 204 candidates shortlisted for interview, seven had QI items on their CVs, including one basic IHI certificate. Three discussed their QI work in their PSs, and four had recommendation letters describing their involvement in QI. One applicant had both CV and LOR evidence, so that 13 (6%) documented QI engagement. Practice of or instruction in QI is rarely mentioned in application documents of prospective internal medicine interns.
Protocol for laparoscopic cholecystectomy: Is it rocket science?
Hori, Tomohide; Oike, Fumitaka; Furuyama, Hiroaki; Machimoto, Takafumi; Kadokawa, Yoshio; Hata, Toshiyuki; Kato, Shigeru; Yasukawa, Daiki; Aisu, Yuki; Sasaki, Maho; Kimura, Yusuke; Takamatsu, Yuichiro; Naito, Masato; Nakauchi, Masaya; Tanaka, Takahiro; Gunji, Daigo; Nakamura, Kiyokuni; Sato, Kiyoko; Mizuno, Masahiro; Iida, Taku; Yagi, Shintaro; Uemoto, Shinji; Yoshimura, Tsunehiro
2016-12-21
Laparoscopic cholecystectomy (LC) does not require advanced techniques, and its performance has therefore rapidly spread worldwide. However, the rate of biliary injuries has not decreased. The concept of the critical view of safety (CVS) was first documented two decades ago. Unexpected injuries are principally due to misidentification of human factors. The surgeon's assumption is a major cause of misidentification, and a high level of experience alone is not sufficient for successful LC. We herein describe tips and pitfalls of LC in detail and discuss various technical considerations. Finally, based on a review of important papers and our own experience, we summarize the following mandatory protocol for safe LC: (1) consideration that a high level of experience alone is not enough; (2) recognition of the plateau involving the common hepatic duct and hepatic hilum; (3) blunt dissection until CVS exposure; (4) Calot's triangle clearance in the overhead view; (5) Calot's triangle clearance in the view from underneath; (6) dissection of the posterior right side of Calot's triangle; (7) removal of the gallbladder body; and (8) positive CVS exposure. We believe that adherence to this protocol will ensure successful and beneficial LC worldwide, even in patients with inflammatory changes and rare anatomies.
Tip-Enhanced Raman Voltammetry: Coverage Dependence and Quantitative Modeling.
Mattei, Michael; Kang, Gyeongwon; Goubert, Guillaume; Chulhai, Dhabih V; Schatz, George C; Jensen, Lasse; Van Duyne, Richard P
2017-01-11
Electrochemical atomic force microscopy tip-enhanced Raman spectroscopy (EC-AFM-TERS) was employed for the first time to observe nanoscale spatial variations in the formal potential, E 0' , of a surface-bound redox couple. TERS cyclic voltammograms (TERS CVs) of single Nile Blue (NB) molecules were acquired at different locations spaced 5-10 nm apart on an indium tin oxide (ITO) electrode. Analysis of TERS CVs at different coverages was used to verify the observation of single-molecule electrochemistry. The resulting TERS CVs were fit to the Laviron model for surface-bound electroactive species to quantitatively extract the formal potential E 0' at each spatial location. Histograms of single-molecule E 0' at each coverage indicate that the electrochemical behavior of the cationic oxidized species is less sensitive to local environment than the neutral reduced species. This information is not accessible using purely electrochemical methods or ensemble spectroelectrochemical measurements. We anticipate that quantitative modeling and measurement of site-specific electrochemistry with EC-AFM-TERS will have a profound impact on our understanding of the role of nanoscale electrode heterogeneity in applications such as electrocatalysis, biological electron transfer, and energy production and storage.
[Photographic documentation during safe laparoscopic cholecystectomy].
Bolívar-Rodríguez, Martín A; Pamanes-Lozano, Adrián; Matus-Rojas, Jaime; Cázarez-Aguilar, Marcel A; Fierro-López, Rodolfo
2018-01-01
Laparoscopic cholecystectomy is the most frequent procedure for the general surgeon. Biliary injury is a concern that must be addressed with the purpose of lowering the rate. The critical view of safety (CVS) is a target of dissection that impulses safety during the procedure. Determine by an ambispective analysis the safety during dissection of laparoscopic cholecystectomy in Hospital Civil de Culiacán (México). Descriptive, ambispective, observational, cross-sectional. Patients admitted to the operating room for a laparoscopic cholecystectomy were scored with Doublet photography rating criteria from January 1 st 2015 to January 31, 2017. 321 patients were evaluated, 77.9% were female and 22.1% male. The mean age was 45.57 ± 16.17 years. 65.4% had admission diagnosis of cholelithiasis, 24.3% acute cholecystitis, 5.9% chronic cholecystitis, 3.7% hydrocolecist and 0.6% pyocolecist. Surgeries were scored with Doublet photography. The CVS was obtained in 41.4% of the procedures with a statistical significance between a HPB surgeon and a general surgery resident (p ≤ 0.05). Recording Doublet photography provides a reliable CVS dissection criterion. It can be easily reproduced during laparoscopic cholecystectomy. The identification of cystic structures adds to the culture of safety during laparoscopic cholecystectomy. Copyright: © 2018 Permanyer.
NASA Astrophysics Data System (ADS)
Voronkov, Yury; Skedina, Marina; Degterenkova, Natalia; Stepanova, Galina
Long stay of cosmonauts in conditions of International Space Station demands the increased medical control over their health during selection. Various parameters of cardiovascular system (CVS) undergo significant changes both during adaptation to space flight (period of removing into an orbit), directly under conditions of weightlessness and during readaptation to terrestrial environment. The CVS is sensitive indicator of adaptation reaction of total organism. Therefore much attention is given to the research of CVS regulation, its opportunities to adapt to various stress conditions, detection of pre-nozological changes in mechanisms of its regulation. One of the informative methods for detecting problems in CVS regulation is a postural orthostatic test. This work was designed to research regulation of hemodynamics during passive orthostatic test. 21 practically healthy people in the age from 18 to 36 years old have passed the test. During test the following parameters were registered: 12 Lead ECG and the BP, parameters of a myocardium by means of "CardioVisor-06" (CV) device, and also a condition of microcirculatory bloodstream (MCB) was estimated by means of ultrasonic high-frequency dopplerograph "Minimax-Doppler-K" with 20 MHz sensor. The impedance method of rheoencephalography (REG) by means of the "Encephalan-EEGR-13103" device was used to research a cerebral blood circulation. All subjects had normal parameters of ECG during test. However, during analysis data of CV, REG and MCB high tolerability to the test was observed in 14 test subjects. In other 7 subjects dynamics of parameters during test reflected problems in mechanisms of CVS regulation in its separate parts. Changes in parameters of REG and ultrasound in 4 test subjects reflected a hypotensive reaction. The parameter of a tone of arterioles in carotid and vertebral arteries system decreased for 15,3 % and 55,2 % accordingly. The parameters of MCB: average speed, vascular tone and peripheric resistance were decreased. Changes in parameters of REG and MCB in 3 test subjects reflected a hypertensive reaction. According to REG the parameter of vascular tone in vessels of medium and small caliber has increased during test more 100 %, microcirculatory more 30 % with fist minutes test. It is necessary to note, that during test initial changes with repolarization of both left and right auricles were noticed in these subjects, integrate parameter «Myocardium» increased on 39 %, parameter «Rhythm» increased on 34,5% to CV data.
Monitoring Accreting X-ray Pulsars with the GLAST Burst Monitor
NASA Technical Reports Server (NTRS)
Wilson, Colleen A.; Finger, Mark H.; Patel, Sandeep K.; Bhat, P. Narayana; Preece, Robert D.; Meegan, Charles A.
2007-01-01
Accreting pulsars are exceptionally good laboratories for probing the detailed physics of accretion onto magnetic stars. While similar accretion flows also occur in other types of astrophysical systems, e.g. magnetic CVs, only neutron stars have a small enough moment of inertia for the accretion of angular momentum to result in measurable changes in spin-frequency in a timescale of days. Long-term monitoring of accreting pulsar spin-frequencies and fluxes was demonstrated with the Burst and Transient Source Experiment (BATSE) on the Compton Gamma Ray Observatory. Here we present sample results from BATSE, discuss measurement techniques appropriate for GBM, and estimate the expected GBM sensitivity.
Period changes of cataclysmic variables below the period gap: V2051 Oph, OY Car and Z Cha
NASA Astrophysics Data System (ADS)
Pilarčík, L.; Wolf, M.; Zasche, P.; Vraštil, J.
2018-04-01
We present our results of a long-term monitoring of cataclysmic variable stars (CVs). About 40 new eclipses were measured for the three southern SU UMa-type eclipsing CVs: V2051 Oph, OY Car and Z Cha. Based on the current O - C diagrams we confirmed earlier findings that V2051 Oph and OY Car present cyclic changes of their orbital periods lasting 25 and 29 years, respectively. In case of Z Cha we propose the light-time effect caused probably by a presence of the third component orbiting the eclipsing CV with the period of 43.5 years. The minimal mass of this companion results about 15 MJup.
Optical hybrid quantum teleportation and its applications
NASA Astrophysics Data System (ADS)
Takeda, Shuntaro; Okada, Masanori; Furusawa, Akira
2017-08-01
Quantum teleportation, a transfer protocol of quantum states, is the essence of many sophisticated quantum information protocols. There have been two complementary approaches to optical quantum teleportation: discrete variables (DVs) and continuous variables (CVs). However, both approaches have pros and cons. Here we take a "hybrid" approach to overcome the current limitations: CV quantum teleportation of DVs. This approach enabled the first realization of deterministic quantum teleportation of photonic qubits without post-selection. We also applied the hybrid scheme to several experiments, including entanglement swapping between DVs and CVs, conditional CV teleportation of single photons, and CV teleportation of qutrits. We are now aiming at universal, scalable, and fault-tolerant quantum computing based on these hybrid technologies.
Stability and reproducibility of proteomic profiles measured with an aptamer-based platform.
Kim, Claire H; Tworoger, Shelley S; Stampfer, Meir J; Dillon, Simon T; Gu, Xuesong; Sawyer, Sherilyn J; Chan, Andrew T; Libermann, Towia A; Eliassen, A Heather
2018-05-30
The feasibility of SOMAscan, a multiplex, high sensitivity proteomics platform, for use in studies using archived plasma samples has not yet been assessed. We quantified 1,305 proteins from plasma samples donated by 16 Nurses' Health Study (NHS) participants, 40 NHSII participants, and 12 local volunteers. We assessed assay reproducibility using coefficients of variation (CV) from duplicate samples and intra-class correlation coefficients (ICC) and Spearman correlation coefficients (r) of samples processed (i.e., centrifuged and aliquoted into separate components) immediately, 24, and 48 hours after collection, as well as those of samples collected from the same individuals 1 year apart. CVs were <20% for 99% of proteins overall and <10% for 92% of proteins in heparin samples compared to 66% for EDTA samples. We observed ICC or Spearman r (comparing immediate vs. 24-hour delayed processing) ≥0.75 for 61% of proteins, with some variation by anticoagulant (56% for heparin and 70% for EDTA) and protein class (ranging from 49% among kinases to 83% among hormones). Within-person stability over 1 year was good (ICC or Spearman r ≥ 0.4) for 91% of proteins. These results demonstrate the feasibility of SOMAscan for analyses of archived plasma samples.
Recent Progress in Understanding Coxsackievirus Replication, Dissemination, and Pathogenesis
Sin, Jon; Mangale, Vrushali; Thienphrapa, Wdee; Gottlieb, Roberta A.; Feuer, Ralph
2015-01-01
Coxsackieviruses (CVs) are relatively common viruses associated with a number of serious human diseases, including myocarditis and meningo-encephalitis. These viruses are considered cytolytic yet can persist for extended periods of time within certain host tissues requiring evasion from the host immune response and a greatly reduced rate of replication. A member of Picornaviridae family, CVs have been historically considered non-enveloped viruses – although recent evidence suggest that CV and other picornaviruses hijack host membranes and acquire an envelope. Acquisition of an envelope might provide distinct benefits to CV virions, such as resistance to neutralizing antibodies and efficient nonlytic viral spread. CV exhibits a unique tropism for progenitor cells in the host which may help to explain the susceptibility of the young host to infection and the establishment of chronic disease in adults. CVs have also been shown to exploit autophagy to maximize viral replication and assist in unconventional release from target cells. In this article, we review recent progress in clarifying virus replication and dissemination within the host cell, identifying determinants of tropism, and defining strategies utilized by the virus to evade the host immune response. Also, we will highlight unanswered questions and provide future perspectives regarding the potential mechanisms of CV pathogenesis. PMID:26142496
Factors in Variability of Serial Gabapentin Concentrations in Elderly Patients with Epilepsy.
Conway, Jeannine M; Eberly, Lynn E; Collins, Joseph F; Macias, Flavia M; Ramsay, R Eugene; Leppik, Ilo E; Birnbaum, Angela K
2017-10-01
To characterize and quantify the variability of serial gabapentin concentrations in elderly patients with epilepsy. This study included 83 patients (age ≥ 60 yrs) from an 18-center randomized double-blind double-dummy parallel study from the Veterans Affairs Cooperative 428 Study. All patients were taking 1500 mg/day gabapentin. Within-person coefficient of variation (CV) in gabapentin concentrations, measured weekly to bimonthly for up to 52 weeks, then quarterly, was computed. Impact of patient characteristics on gabapentin concentrations (linear mixed model) and CV (linear regression) were estimated. A total of 482 gabapentin concentration measurements were available for analysis. Gabapentin concentrations and intrapatient CVs ranged from 0.5 to 22.6 μg/ml (mean 7.9 μg/ml, standard deviation [SD] 4.1 μg/ml) and 2% to 79% (mean 27.9%, SD 15.3%), respectively, across all visits. Intrapatient CV was higher by 7.3% for those with a body mass index of ≥ 30 kg/m 2 (coefficient = 7.3, p=0.04). CVs were on average 0.5% higher for each 1-unit higher CV in creatinine clearance (coefficient = 0.5, p=0.03) and 1.2% higher for each 1-hour longer mean time after dose (coefficient = 1.2, p=0.04). Substantial intrapatient variability in serial gabapentin concentration was noted in elderly patients with epilepsy. Creatinine clearance, time of sampling relative to dose, and obesity were found to be positively associated with variability. © 2017 Pharmacotherapy Publications, Inc.
Performance evaluation of the Arkray Adams HA-8160 HbA1c analyser.
Thevarajah, T Malathi; Nani, Nordin; Chew, Y Y
2008-12-01
HbA1c measurement is currently routinely used to predict long term outcome of diabetes, thus playing a fundamental role in the management of diabetes. The relationship between HbA1c value and long term diabetic complications has been established by a randomised control Diabetes Control and Complications Trial (DCCT) which used high performance liquid chromatography (HPLC) as a reference method for HbA1c assay. To ensure that HbA1c results from a variety HbA1c assay methods are similar to the DCCT values, the American Diabetes Association (ADA) recommended that all laboratories should use methods certified by the National Glycohemoglobin Standardization Programme (NGSP) with interassay coefficient variation (CV) of < 5% (ideally < 3%). The International Federation of Clinical Chemistry (IFCC) working group on HbA1c standardisation has set a CV < 2.5% as a criteria for its reference laboratories. To evaluate the performance of Arkray Adams HA-8160 HbA1c analyser which uses a cation exchange HPLC method and its correlation to HbA1c assay on Cobas Integra 800 which is an immunoturbidimetric method. For the imprecision study, patient samples and control material of two levels were analysed on HA-8160 analyser 20 times in a single run (within-run imprecision) and twice a day on five consecutive days (between-run imprecision). For the recovery study, two samples each with high and low values were selected and mixed in ratios of 1:3, 1:1 and 3:1, and were analysed by HA-8160. Sixty samples were analysed by both Cobas Integra 800 and HA-8160 for method comparison study. Ten uraemic samples and ten thalassaemic samples were assayed on Cobas Integra 800 and HA 8160 for interference study. Within-run CVs were 0.6% and 0.7% for medium and high value samples respectively, 0.6% and 0.7% for low and high level controls respectively. Between-run CVs were 0.5% and 0.4% for medium and high value samples respectively, 0.5% and 0.6% for low and high level controls respectively. The mean recovery was 100.1%. A good correlation between the 2 methods (Adams = 1.00 Cobas - 0.11, r = 0.98) was observed. The Akray Adams HA-8160 HbA1c analyser performed within the target CV of < 2.5% and showed a good correlation with the Cobas Integra 800.
NASA Astrophysics Data System (ADS)
Gaunt, R. A.; Hokanson, J. A.; Weber, D. J.
2009-10-01
Current research in motor neural prosthetics has focused primarily on issues related to the extraction of motor command signals from the brain (e.g. brain-machine interfaces) to direct the motion of prosthetic limbs. Patients using these types of systems could benefit from a somatosensory neural interface that conveys natural tactile and kinesthetic sensations for the prosthesis. Electrical microstimulation within the dorsal root ganglia (DRG) has been proposed as one method to accomplish this, yet little is known about the recruitment properties of electrical microstimulation in activating nerve fibers in this structure. Current-controlled microstimulation pulses in the range of 1-15 µA (200 µs, leading cathodic pulse) were delivered to the L7 DRG in four anesthetized cats using penetrating microelectrode arrays. Evoked responses and their corresponding conduction velocities (CVs) were measured in the sciatic nerve with a 5-pole nerve cuff electrode arranged as two adjacent tripoles. It was found that in 76% of the 69 electrodes tested, the stimulus threshold was less than or equal to 3 µA, with the lowest recorded threshold being 1.1 µA. The CVs of afferents recruited at threshold had a bimodal distribution with peaks at 70 m s-1 and 85 m s-1. In 53% of cases, the CV of the response at threshold was slower (i.e. smaller diameter fiber) than the CVs of responses observed at increasing stimulation amplitudes. In summary, we found that microstimulation applied through penetrating microelectrodes in the DRG provides selective recruitment of afferent fibers from a range of sensory modalities (as identified by CVs) at very low stimulation intensities. We conclude that the DRG may serve as an attractive location from which to introduce surrogate somatosensory feedback into the nervous system.
Wakabayashi, Go; Iwashita, Yukio; Hibi, Taizo; Takada, Tadahiro; Strasberg, Steven M; Asbun, Horacio J; Endo, Itaru; Umezawa, Akiko; Asai, Koji; Suzuki, Kenji; Mori, Yasuhisa; Okamoto, Kohji; Pitt, Henry A; Han, Ho-Seong; Hwang, Tsann-Long; Yoon, Yoo-Seok; Yoon, Dong-Sup; Choi, In-Seok; Huang, Wayne Shih-Wei; Giménez, Mariano Eduardo; Garden, O James; Gouma, Dirk J; Belli, Giulio; Dervenis, Christos; Jagannath, Palepu; Chan, Angus C W; Lau, Wan Yee; Liu, Keng-Hao; Su, Cheng-Hsi; Misawa, Takeyuki; Nakamura, Masafumi; Horiguchi, Akihiko; Tagaya, Nobumi; Fujioka, Shuichi; Higuchi, Ryota; Shikata, Satoru; Noguchi, Yoshinori; Ukai, Tomohiko; Yokoe, Masamichi; Cherqui, Daniel; Honda, Goro; Sugioka, Atsushi; de Santibañes, Eduardo; Supe, Avinash Nivritti; Tokumura, Hiromi; Kimura, Taizo; Yoshida, Masahiro; Mayumi, Toshihiko; Kitano, Seigo; Inomata, Masafumi; Hirata, Koichi; Sumiyama, Yoshinobu; Inui, Kazuo; Yamamoto, Masakazu
2018-01-01
In some cases, laparoscopic cholecystectomy (LC) may be difficult to perform in patients with acute cholecystitis (AC) with severe inflammation and fibrosis. The Tokyo Guidelines 2018 (TG18) expand the indications for LC under difficult conditions for each level of severity of AC. As a result of expanding the indications for LC to treat AC, it is absolutely necessary to avoid any increase in bile duct injury (BDI), particularly vasculo-biliary injury (VBI), which is known to occur at a certain rate in LC. Since the Tokyo Guidelines 2013 (TG13), an attempt has been made to assess intraoperative findings as objective indicators of surgical difficulty; based on expert consensus on these difficulty indicators, bail-out procedures (including conversion to open cholecystectomy) have been indicated for cases in which LC for AC is difficult to perform. A bail-out procedure should be chosen if, when the Calot's triangle is appropriately retracted and used as a landmark, a critical view of safety (CVS) cannot be achieved because of the presence of nondissectable scarring or severe fibrosis. We propose standardized safe steps for LC to treat AC. To achieve a CVS, it is vital to dissect at a location above (on the ventral side of) the imaginary line connecting the base of the left medial section (Segment 4) and the roof of Rouvière's sulcus and to fulfill the three criteria of CVS before dividing any structures. Achieving a CVS prevents the misidentification of the cystic duct and the common bile duct, which are most commonly confused. Free full articles and mobile app of TG18 are available at: http://www.jshbps.jp/modules/en/index.php?content_id=47. Related clinical questions and references are also included. © 2018 Japanese Society of Hepato-Biliary-Pancreatic Surgery.
2011-01-01
Background Cerebral vasospasm (CVS) is a common serious complication after the spontaneous subarachnoid hemorrhage (SAH). Despite recent advances in medical and surgical treatments, the 30-day mortality rate of SAH remains high, and there is lack of especially effective clinical treatment to alleviate and improve CVS. The present study has investigated the therapeutic effect of insulin and vitamin C on CVS after SAH. Results Five days after SAH, there is obvious basilar artery spasm in SAH group, whose average vascular cross-sectional area (233,099 ± 16,750 μm2) is significantly smaller than that in control group (462,128 ± 74,756 μm2), which is also significantly different from those in SAH + insulin group (221,114 ± 43,457 μm2) and SAH + vitamin C group (237,820 ± 21,703 μm2). SAH + insulin + vitamin C group shows no evident vasospasm and maintains a vascular cross-sectional area of 425,530 ± 45,503 μm2, which is significantly different from that in SAH group. Insulin receptor α (InRα) expression is significantly downregulated in the vascular endothelial cells of SAH, SAH + insulin, and SAH + vitamin C groups (P < 0.01) but remains unchanged in vascular endothelial cells of SAH + insulin + vitamin C group (P > 0.05). Five days after SAH, serum and cerebrospinal fluid NO levels in SAH, SAH + insulin, and SAH + vitamin C groups decrease significantly (P < 0.01) compared to that in control group, whereas the reduction is not evident in SAH + insulin + vitamin C group (P > 0.05). Conclusion Combinatorial treatment with insulin and vitamin C has effectively relieved the CVS after SAH in rabbit, possibly through increasing the InRα expression and NO level, whereas treatment with insulin or vitamin C alone fails to do so. PMID:21801458
The effect of interferon on the receptor sites to rabies virus on mouse neuroblastoma cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Briggs, D.J.
1989-01-01
The binding of rabies virus to mouse neuroblastoma cells (MNA) primed with alpha interferon (IFN-{alpha}), beta interferon (IFN-{beta}), or alpha bungarotoxin (BTX) was examined. A saturable number of receptor sites to rabies virus was calculated by increasing the amount of {sup 3}H-CVS added to a constant number of untreated MNA cells. MNA cells were then exposed to 20 I.U. of IFN-{alpha}, IFN-{beta}, or 1 {mu}g of BTX and assayed to determine if these treatments had an effect on the number of receptor sites to rabies virus. Total amount of {sup 3}H-CVS bound to MNA cells was determined during a threemore » hour incubation period. Cold competition assays using 1,000 fold excess unlabeled CVS were used to determine non-specific binding for each treatment. Specific binding was then calculated by subtracting non-specific binding from the total amount of CVS bound to MNA cells. A similar amount of total viral protein bound to untreated and IFN-{beta}, and BTX treated cells after 180 minutes of incubation. The bound protein varied by only 0.07 {mu}g. However, the amount of specific and non-specific binding varied a great deal between treatments. BTX caused an increase in non-specific and a decrease in specific binding of rabies virus. IFN-{beta} produced variable results in non-specific and specific binding while IFN-{alpha} caused mainly specific binding to occur. The most significant change brought about by IFN-{alpha} was an increase in the rate of viral attachment. At 30 minutes post-infection, IFN-{alpha} treated cells had bound 90% of the total amount of virus bound to untreated cells after 180 minutes. The increased binding rate did not cause a productive infection of rabies virus. No viral production was evident after an incubation period of 48 hours in either IFN-{alpha} or IFN-{beta} treated cells.« less
Computer Vision Syndrome and Associated Factors Among Medical and Engineering Students in Chennai
Logaraj, M; Madhupriya, V; Hegde, SK
2014-01-01
Background: Almost all institutions, colleges, universities and homes today were using computer regularly. Very little research has been carried out on Indian users especially among college students the effects of computer use on the eye and vision related problems. Aim: The aim of this study was to assess the prevalence of computer vision syndrome (CVS) among medical and engineering students and the factors associated with the same. Subjects and Methods: A cross-sectional study was conducted among medical and engineering college students of a University situated in the suburban area of Chennai. Students who used computer in the month preceding the date of study were included in the study. The participants were surveyed using pre-tested structured questionnaire. Results: Among engineering students, the prevalence of CVS was found to be 81.9% (176/215) while among medical students; it was found to be 78.6% (158/201). A significantly higher proportion of engineering students 40.9% (88/215) used computers for 4-6 h/day as compared to medical students 10% (20/201) (P < 0.001). The reported symptoms of CVS were higher among engineering students compared with medical students. Students who used computer for 4-6 h were at significantly higher risk of developing redness (OR = 1.2, 95% CI = 1.0-3.1,P = 0.04), burning sensation (OR = 2.1,95% CI = 1.3-3.1, P < 0.01) and dry eyes (OR = 1.8, 95% CI = 1.1-2.9, P = 0.02) compared to those who used computer for less than 4 h. Significant correlation was found between increased hours of computer use and the symptoms redness, burning sensation, blurred vision and dry eyes. Conclusion: The present study revealed that more than three-fourth of the students complained of any one of the symptoms of CVS while working on the computer. PMID:24761234
Computer vision syndrome and associated factors among medical and engineering students in chennai.
Logaraj, M; Madhupriya, V; Hegde, Sk
2014-03-01
Almost all institutions, colleges, universities and homes today were using computer regularly. Very little research has been carried out on Indian users especially among college students the effects of computer use on the eye and vision related problems. The aim of this study was to assess the prevalence of computer vision syndrome (CVS) among medical and engineering students and the factors associated with the same. A cross-sectional study was conducted among medical and engineering college students of a University situated in the suburban area of Chennai. Students who used computer in the month preceding the date of study were included in the study. The participants were surveyed using pre-tested structured questionnaire. Among engineering students, the prevalence of CVS was found to be 81.9% (176/215) while among medical students; it was found to be 78.6% (158/201). A significantly higher proportion of engineering students 40.9% (88/215) used computers for 4-6 h/day as compared to medical students 10% (20/201) (P < 0.001). The reported symptoms of CVS were higher among engineering students compared with medical students. Students who used computer for 4-6 h were at significantly higher risk of developing redness (OR = 1.2, 95% CI = 1.0-3.1,P = 0.04), burning sensation (OR = 2.1,95% CI = 1.3-3.1, P < 0.01) and dry eyes (OR = 1.8, 95% CI = 1.1-2.9, P = 0.02) compared to those who used computer for less than 4 h. Significant correlation was found between increased hours of computer use and the symptoms redness, burning sensation, blurred vision and dry eyes. The present study revealed that more than three-fourth of the students complained of any one of the symptoms of CVS while working on the computer.
Significance of Blunted Venous Waveforms Seen on Upper Extremity Ultrasound.
Pham, Xuan-Binh D; Ihenachor, Ezinne J; Wu, Hoover; Kim, Jerry J; Kaji, Amy H; Koopmann, Matthew C; Ryan, Timothy J; de Virgilio, Christian
2017-07-01
Current guidelines recommend vascular mapping ultrasound (US) prior to arteriovenous fistula creation. Blunted venous waveforms (BVWs) suggest central venous stenosis; however, this relationship and one between BVWs and the presence of a central venous catheter (CVC) remain unclear. All patients who received upper extremity vascular mapping US between January 2013 and October 2014 at a single institution were retrospectively reviewed. Patient demographics, comorbidities, US results, pacemaker history, and CVC status were collected. Waveforms were assessed at the proximal subclavian vein/distal axillary vein and interpreted by radiologists. Patients were determined to have central venous stenosis (CVS) if detected by venography within 6 months of US. There were 342 patients, of which 165 (48%) had a current CVC and 29 (8.5%) had BVW of at least 1 arm. Right-sided BVW were associated with a history of a prior ipsilateral CVC (odds ratio [OR] = 4.5, 95% confidence interval [CI] = 1.6-12.6, P = 0.009). Of the 342 patients, 69 (20%) had a venogram within 6 months. Seventeen (25%) of the 69 patients had CVS, with 7 involving the left subclavian vein, 8 the right subclavian vein, and 3 the superior vena cava (one patient had tandem stenoses). A BVW on the left side was not associated with any CVS. A BVW on the right side was associated with an ipsilateral CVS (OR = 5.8, 95% CI = 1.2-27.4, P = 0.04). This association persisted in the setting of a prior CVC (relative risk = 1.3, 95% CI = 0.9-2, P = 0.01). There are associations between right-sided BVW and an ipsilateral subclavian vein stenosis. We recommend that hemodialysis access planning includes venography to rule out central vein stenosis in patients with BVW, especially if right-sided and in the setting of a prior CVC. Copyright © 2017 Elsevier Inc. All rights reserved.
Zhao, Dong; Liu, Qi; Ji, Yunxiang; Wang, Ganggang; He, Xuejun; Tian, Weidong; Xu, Hui; Lei, Ting; Wang, Yezhong
2015-06-01
Cerebral vasospasm (CVS) after subarachnoid hemorrhage (SAH) is characterized by the severe constriction of an artery, which often leads to unfavorable outcomes. CVS after SAH is closely associated with asymmetric dimethylarginine (ADMA) and connexin. The effect of 18β-glycyrrhetinic acid (18β-GA), an inhibitor of gap junction, on ADMA, connexin, and CVS after SAH were investigated. Sprague-Dawley rats (n = 120), weighing 300-350 g, were divided into the control group, sham, SAH, and SAH + 18β-GA groups. In the SAH group, blood was injected into the prechiasmatic cistern of the rats, and 18β-GA (10 mg/kg) was intraperitoneally injected. The neurological score, basilar artery diameter, ADMA, and connexin protein contents (Cx40, Cx43, and Cx45) were measured using Kaoutzanis scoring system, pressure myograph, enzyme linked immunosorbent assay kit, and Western blot, respectively, 1, 3, 5, 7, and 14 days after SAH. The neurological score significantly decreased 3, 5, 7, and 14 days after SAH. The basilar artery diameter significantly decreased, and the ADMA level in the cerebrospinal fluid (CSF) significantly increased at all time points. The level of Cx40 significantly decreased on days 3, 5, 7, and 14, and the level of Cx43 and Cx45 significantly increased at all time points. ADMA and Cx43 are positively correlated. However, the upregulated level of ADMA, Cx43, and Cx45 were attenuated. The neurology result significantly improved in the SAH + 18β-GA group. Treatment with 18β-GA in SAH rats decreases Cx43 and Cx45 in basilar artery and ADMA in CSF. ADMA is probably involved in the pathophysiological events of CVS after SAH by altering connexin proteins. The mechanism of connexin protein changes caused by ADMA needs to be further studied.
On the Accretion Rates of SW Sextantis Nova-like Variables
NASA Astrophysics Data System (ADS)
Ballouz, Ronald-Louis; Sion, Edward M.
2009-06-01
We present accretion rates for selected samples of nova-like variables having IUE archival spectra and distances uniformly determined using an infrared method by Knigge. A comparison with accretion rates derived independently with a multiparametric optimization modeling approach by Puebla et al. is carried out. The accretion rates of SW Sextantis nova-like systems are compared with the accretion rates of non-SW Sextantis systems in the Puebla et al. sample and in our sample, which was selected in the orbital period range of three to four and a half hours, with all systems having distances using the method of Knigge. Based upon the two independent modeling approaches, we find no significant difference between the accretion rates of SW Sextantis systems and non-SW Sextantis nova-like systems insofar as optically thick disk models are appropriate. We find little evidence to suggest that the SW Sex stars have higher accretion rates than other nova-like cataclysmic variables (CVs) above the period gap within the same range of orbital periods.
White Dwarfs in Cataclysmic Variables: An Update
Sion, Edward M.; Godon, Patrick
2018-01-01
In this review, we summarize what is currently known about the surface temperatures of accreting white dwarfs in non-magnetic and magnetic cataclysmic variables (CVs) based upon synthetic spectral analyses of far ultraviolet data. We focus only on white dwarf surface temperatures, since in the area of chemical abundances, rotation rates, WD masses and accretion rates, relatively little has changed since our last review, pending the results of a large HST GO program involving 48 CVs of different CV types. The surface temperature of the white dwarf in SS Cygni is re-examined in the light of its revised distance. We also discuss new HST spectra of the recurrent nova T Pyxidis as it transitioned into quiescence following its April 2011 nova outburst. PMID:29505036
Estimation of steady-state leakage current in polycrystalline PZT thin films
NASA Astrophysics Data System (ADS)
Podgorny, Yury; Vorotilov, Konstantin; Sigov, Alexander
2016-09-01
Estimation of the steady state (or "true") leakage current Js in polycrystalline ferroelectric PZT films with the use of the voltage-step technique is discussed. Curie-von Schweidler (CvS) and sum of exponents (Σ exp ) models are studied for current-time J (t) data fitting. Σ exp model (sum of three or two exponents) gives better fitting characteristics and provides good accuracy of Js estimation at reduced measurement time thus making possible to avoid film degradation, whereas CvS model is very sensitive to both start and finish time points and give in many cases incorrect results. The results give rise to suggest an existence of low-frequency relaxation processes in PZT films with characteristic duration of tens and hundreds of seconds.
Determination of emamectin benzoate in medicated fish feed.
Farer, L J; Hayes, J; Rosen, J; Knight, P
1999-01-01
A method was developed to quantitate emamectin benzoate in fish feed at levels between 5 and 15 ppm. The active ingredient is extracted from 20 g medicated feed into aqueous-methanolic solvent by overnight shaking. A solid-phase extraction procedure using a 2 g C18 cartridge is then used to concentrate the active residue and remove interfering matrix components. The extracted drug and internal standard are eluted from the cartridge, evaporated to dryness, and reconstituted in methanol. A control feed sample and fortified control working standard are simultaneously prepared. Remaining interferences and sample analysis are further separated on a gradient liquid chromatographic system. Recovery of emamectin benzoate from fortified feeds ranged from 97 to 100%, with a coefficient of variation (CV) of 1.2%. Determination of emamectin benzoate in medicated feeds resulted in CVs ranging from 2.3 to 4.2% and recoveries of 88 to 98% of label claim.
Page, Allen E; Stills, Harold F; Horohov, David W
2014-12-15
In the horse, Lawsonia intracellularis infection results in equine proliferative enteropathy (EPE). While upwards of 100% of weanlings on an endemic farm may seroconvert, only a small percentage (approximately 5%) will develop clinical disease. Cell-mediated immune mechanisms likely play a role in resistance to L. intracellularis and the absence of a L. intracellularis-specific IFN-γ response has been associated with the development of EPE. The goal of this study was to determine whether protection from clinical EPE is associated with the induction of a systemic IgG sub-isotypic response consistent with a Th1-type cytokine response. To describe their L. intracellularis/EPE status, horses enrolled in this study were placed into one of three categories: seropositive-only, vaccinated, and presumptive clinical EPE. An existing ELISA method was modified to detect L. intracellularis-specific IgG(a), IgG(b), and IgG(t) antibodies using the mouse anti-equine hybridomas CVS-48, CVS-39, and CVS-40, respectively. Additionally, the existing ELISA method was used to quantify total IgG antibodies specific for L. intracellularis for comparison between the groups. Total L. intracellularis-specific IgG was found to be significantly higher (p<0.05) in presumptive clinical EPE cases (n=21) when compared with seropositive (exposed but unaffected) (n=36) and vaccinated horses (n=27). Further, a similar pattern for IgG(a) was seen in that the presumptive clinical EPE horses had significantly more L. intracellularis-specific IgG(a) (p<0.05) than the seropositive or vaccinated horses. With IgG(b), however, the vaccinated horses had significantly more IgG(b) (p<0.05) than the presumptive clinical or seropositive horses. No L. intracellularis-specific IgG(t) was detected in samples from any of the groups. While the results presented here with respect to IgG(a) response in the presumptive clinical EPE group were expected, a higher concentration of IgG(a) was anticipated in the seropositive horses that failed to develop clinical disease as well as in the vaccinated horses. Future work utilizing newer reagents against a broader range of equine IgG sub-isotypes may provide additional information once these become commercially available. Copyright © 2014 Elsevier B.V. All rights reserved.
Nishikimi, Toshio; Okamoto, Hiroyuki; Nakamura, Masahiro; Ogawa, Naoko; Horii, Kazukiyo; Nagata, Kiyoshi; Nakagawa, Yasuaki; Kinoshita, Hideyuki; Yamada, Chinatsu; Nakao, Kazuhiro; Minami, Takeya; Kuwabara, Yoshihiro; Kuwahara, Koichiro; Masuda, Izuru; Kangawa, Kenji; Minamino, Naoto; Nakao, Kazuwa
2013-01-01
Background Recent studies have shown that in addition to brain (or B-type) natriuretic peptide (BNP) and the N-terminal proBNP fragment, levels of intact proBNP are also increased in heart failure. Moreover, present BNP immunoassays also measure proBNP, as the anti-BNP antibody cross-reacts with proBNP. It is important to know the exact levels of proBNP in heart failure, because elevation of the low-activity proBNP may be associated with the development of heart failure. Methodology/Principal Findings We therefore established a two-step immunochemiluminescent assay for total BNP (BNP+proBNP) and proBNP using monoclonal antibodies and glycosylated proBNP as a standard. The assay enables measurement of plasma total BNP and proBNP within only 7 h, without prior extraction of the plasma. The detection limit was 0.4 pmol/L for a 50-µl plasma sample. Within-run CVs ranged from 5.2%–8.0% in proBNP assay and from 7.0%–8.4% in total BNP assay, and between-run CVs ranged from 5.3–7.4% in proBNP assay and from 2.9%–9.5% in total BNP assay, respectively. The dilution curves for plasma samples showed good linearity (correlation coefficients = 0.998–1.00), and analytical recovery was 90–101%. The mean total BNP and proBNP in plasma from 116 healthy subjects were 1.4±1.2 pM and 1.0±0.7 pM, respectively, and were 80±129 pM and 42±70 pM in 32 heart failure patients. Plasma proBNP levels significantly correlate with age in normal subjects. Conclusions/Significance Our immunochemiluminescent assay is sufficiently rapid and precise for routine determination of total BNP and proBNP in human plasma. PMID:23365636
Application of multiplex arrays for cytokine and chemokine profiling of bile.
Kemp, Troy J; Castro, Felipe A; Gao, Yu-Tang; Hildesheim, Allan; Nogueira, Leticia; Wang, Bing-Sheng; Sun, Lu; Shelton, Gloriana; Pfeiffer, Ruth M; Hsing, Ann W; Pinto, Ligia A; Koshiol, Jill
2015-05-01
Gallbladder disease is highly related to inflammation, but the inflammatory processes are not well understood. Bile provides a direct substrate in assessing the local inflammatory response that develops in the gallbladder. To assess the reproducibility of measuring inflammatory markers in bile, we designed a methods study of 69 multiplexed immune-related markers measured in bile obtained from gallstone patients. To evaluate assay performance, a total of 18 bile samples were tested twice within the same plate for each analyte, and the 18 bile samples were tested on two different days for each analyte. We used the following performance parameters: detectability, coefficient of variation (CV), intraclass correlation coefficient (ICC), and percent agreement (concordance among replicate measures above and below detection limit). Furthermore, we examined the association of analyte levels with gallstone characteristics such as type, numbers, and size. All but 3 analytes (Stem Cell Factor, SCF; Thrombopoietin, TPO; sIL-1RI) were detectable in bile. 52 of 69 (75.4%) analytes had detectable levels for at least 50% of the subjects tested. The within-plate CVs were ⩽25% for 53 of 66 (80.3%) detectable analytes, and across-plate CVs were ⩽25% for 32 of 66 (48.5%) detectable analytes. Moreover, 64 of 66 (97.0%) analytes had ICC values of at least 0.8. Lastly, the percent agreement was high between replicates for all of the analytes (median; within plate, 97.2%; across plate, 97.2%). In exploratory analyses, we assessed analyte levels by gallstone characteristics and found that levels for several analytes decreased with increasing size of the largest gallstone per patient. Our data suggest that multiplex assays can be used to reliably measure cytokines and chemokines in bile. In addition, gallstone size was inversely related to the levels of select analytes, which may aid in identifying critical pathways and mechanisms associated with the pathogenesis of gallbladder diseases. Copyright © 2015 Elsevier Ltd. All rights reserved.
Founds, Sandra A.; Conley, Yvette P.; Lyons-Weiler, James F.; Jeyabalan, Arun; Hogge, W. Allen; Conrad, Kirk P.
2009-01-01
Background Preeclampsia is a pregnancy-specific disorder that remains a leading cause of maternal, fetal and neonatal morbidity and mortality, and is associated with risk for future cardiovascular disease. There are no reliable predictors, specific preventative measures or treatments other than delivery. A widely-held view is that the antecedents of preeclampsia lie with impaired placentation in early pregnancy. Accordingly, we hypothesized dysregulation of global gene expression in first trimester placentas of women who later manifested preeclampsia. Methods Surplus chorionic villus sampling (CVS) tissues were collected at 10–12 weeks gestation in 160 patients with singleton fetuses. Four patients developed preeclampsia, and their banked CVS specimens were matched to 8 control samples from patients with unaffected pregnancies. Affymetrix HG-U133 Plus 2.0 GeneChips were utilized for microarray analysis. Naïve Bayes prediction modeling and pathway analysis were conducted. qRT-PCR examined three of the dysregulated genes. Results Thirty-six differentially expressed genes were identified in the preeclampsia placentas. qRT-PCR verified the microarray analysis. Thirty-one genes were down-regulated. Many were related to inflammation/immunoregulation and cell motility. Decidual gene dysregulation was prominent. No evidence was found for alterations in hypoxia and oxidative stress regulated genes. Conclusions To our knowledge, this is the first study to show dysregulation of gene expression in the early placentas of women ~6 months before developing preeclampsia, thereby reinforcing a placental origin of the disorder. We hypothesize that placentation in preeclampsia is compromised in the first trimester by maternal and fetal immune dysregulation, abnormal decidualization, or both, thereby impairing trophoblast invasion. Several of the genes provide potential targets for the development of clinical biomarkers in maternal blood during the first trimester. Supplementary materials are available for this article via the publisher’s online edition. PMID:19027158
Mahato, Niladri K; Montuelle, Stephane; Cotton, John; Williams, Susan; Thomas, James; Clark, Brian
2016-05-18
Single or biplanar video radiography and Roentgen stereophotogrammetry (RSA) techniques used for the assessment of in-vivo joint kinematics involves application of ionizing radiation, which is a limitation for clinical research involving human subjects. To overcome this limitation, our long-term goal is to develop a magnetic resonance imaging (MRI)-only, three dimensional (3-D) modeling technique that permits dynamic imaging of joint motion in humans. Here, we present our initial findings, as well as reliability data, for an MRI-only protocol and modeling technique. We developed a morphology-based motion-analysis technique that uses MRI of custom-built solid-body objects to animate and quantify experimental displacements between them. The technique involved four major steps. First, the imaging volume was calibrated using a custom-built grid. Second, 3-D models were segmented from axial scans of two custom-built solid-body cubes. Third, these cubes were positioned at pre-determined relative displacements (translation and rotation) in the magnetic resonance coil and scanned with a T1 and a fast contrast-enhanced pulse sequences. The digital imaging and communications in medicine (DICOM) images were then processed for animation. The fourth step involved importing these processed images into an animation software, where they were displayed as background scenes. In the same step, 3-D models of the cubes were imported into the animation software, where the user manipulated the models to match their outlines in the scene (rotoscoping) and registered the models into an anatomical joint system. Measurements of displacements obtained from two different rotoscoping sessions were tested for reliability using coefficient of variations (CV), intraclass correlation coefficients (ICC), Bland-Altman plots, and Limits of Agreement analyses. Between-session reliability was high for both the T1 and the contrast-enhanced sequences. Specifically, the average CVs for translation were 4.31 % and 5.26 % for the two pulse sequences, respectively, while the ICCs were 0.99 for both. For rotation measures, the CVs were 3.19 % and 2.44 % for the two pulse sequences with the ICCs being 0.98 and 0.97, respectively. A novel biplanar imaging approach also yielded high reliability with mean CVs of 2.66 % and 3.39 % for translation in the x- and z-planes, respectively, and ICCs of 0.97 in both planes. This work provides basic proof-of-concept for a reliable marker-less non-ionizing-radiation-based quasi-dynamic motion quantification technique that can potentially be developed into a tool for real-time joint kinematics analysis.
Direct cardiac effects of intracoronary bupivacaine, levobupivacaine and ropivacaine in the sheep
Chang, Dennis H-T; Ladd, Leigh A; Copeland, Susan; Iglesias, Miguel A; Plummer, John L; Mather, Laurence E
2001-01-01
The racemic local anaesthetic agent bupivacaine is widely used clinically for its long duration of action. Levobupivacaine and ropivacaine are bupivacaine enantiopure congeners, developed to improve upon the clinical safety of bupivacaine, especially the risk of fatal arrhythmogenesis. In previous preclinical studies of the safety of these drugs with intravenous administration in conscious ewes over a wide dose range, we found that central nervous system (CNS) excito-toxicity reversed the cardiac depressant effects when doses approached the convulsant threshold and thus precluded accurate comparison of their cardiovascular system (CVS) effects. To study CVS effects over a wide range of doses with minimal CNS and other influences, brief (3 min) infusions of bupivacaine, levobupivacaine or ropivacaine were administered into the left main coronary arteries of previously instrumented conscious ewes (∼50 Kg body weight). After dose-ranging studies, the drugs were compared in a randomized, blinded, parallel group design. Equimolar doses were increased from 8 μmol (≈amp;2.5 mg) in 8 μmol increments, to either a fatal outcome or a 40 μmol (≈amp;12.5 mg) maximum. All three drugs produced tachycardia, decreased myocardial contractility and stroke volume and widening of electrocardiographic QRS complexes. Thirteen of 19 animals died of ventricular fibrillation: four of six with bupivacaine (mean±s.e.mean actual fatal dose: 21.8±6.4 μmol), five of seven with levobupivacaine (22.9±3.5 μmol), four of six with ropivacaine (22.9±5.9 μmol). No significant differences in survival or in fatal doses between these drugs were found. The findings suggest that ropivacaine, levobupivacaine and bupivacaine have similar intrinsic ability to cause direct fatal cardiac toxicity when administered by left intracoronary arterial infusion in conscious sheep and do not explain the differences between the drugs found with intravenous dosage. PMID:11159717
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hrma, P.R.; Piepel, G.F.
1994-12-01
A Composition Variation study (CVS) is being performed within the Pacific Northwest Laboratory Vitrification Technology Development (PVTD) project in support of a future high-level nuclear waste vitrification plant at the Hanford site in Washington. From 1989 to 1994, over 120 nonradioactive glasses were melted and properties measured in five statistically-designed experimental phases. Glass composition is represented by the 10 components SiO{sub 2}, B{sub 2}O{sub 3}, Al{sub 2}O{sub 3}, Fe{sub 2}O{sub 3}, ZrO{sub 2}, Na{sub 2}O, Li{sub 2}O, CaO, MgO, and Others (all remaining components). The properties measured include viscosity ({eta}), electrical conductivity ({epsilon}), glass transition temperature (T{sub g} ), thermalmore » expansion of solid glass ({alpha}{sub s}) and molten glass ({alpha}{sub m}), crystallinity (quenched and canister centerline cooled glasses), liquidus temperature (T{sub L}), durability based on normalized elemental releases from the Materials Characterization Center-1 28-day dissolution test (MCC-1, r{sub mi}) and the 7-day Product Consistency Test (PCT, r{sub pi}), and solution pHs from MCC-1 and PCT. Amorphous phase separation was also evaluated. Empirical first- and second-order mixture models were fit using the CVS data to relate the various properties to glass composition. Equations for calculating the uncertainty associated with property values predicted by the models were also developed. The models were validated using both internal and external data. Other modeling approaches (e.g., non-bridging oxygen, free energy of hydration, phase-equilibria T{sub L}) were investigated for specific properties. A preliminary Qualified Composition Region was developed to identify glass compositions with high confidence of being processable in a melter and meeting waste form acceptance criteria.« less
Determinations of the 12C/13C Ratio for the Secondary Stars of AE Aquarii, SS Cygni, and RU Pegasi
NASA Astrophysics Data System (ADS)
Harrison, Thomas E.; Marra, Rachel E.
2017-07-01
We present new moderate-resolution near-infrared spectroscopy of three CVs obtained using GNIRS on Gemini-North. These spectra covered three 13CO bandheads found in the K-band, allowing us to derive the isotopic abundance ratios for carbon. We find small 12C/13C ratios for all three donor stars. In addition, these three objects show carbon deficits, with AE Aqr being the most extreme ([C/Fe] = -1.4). This result confirms the conjecture that the donor stars in some long-period CVs have undergone considerable nuclear evolution prior to becoming semi-contact binaries. In addition to the results for carbon, we find that the abundance of sodium is enhanced in these three objects, and the secondary stars in both RU Peg and SS Cyg suffer magnesium deficits. Explaining such anomalies appears to require higher mass progenitors than commonly assumed for the donor stars of CVs. Based on observations obtained at the Gemini Observatory, which is operated by the Association of Universities for Research in Astronomy, Inc., under a cooperative agreement with the NSF on behalf of the Gemini partnership: the National Science Foundation (United States), the National Research Council (Canada), CONICYT (Chile), Ministerio de Ciencia, Tecnología e Innovación Productiva (Argentina), and Ministério da Ciência, Tecnologia e Inovação (Brazil).
Using sketch-map coordinates to analyze and bias molecular dynamics simulations
Tribello, Gareth A.; Ceriotti, Michele; Parrinello, Michele
2012-01-01
When examining complex problems, such as the folding of proteins, coarse grained descriptions of the system drive our investigation and help us to rationalize the results. Oftentimes collective variables (CVs), derived through some chemical intuition about the process of interest, serve this purpose. Because finding these CVs is the most difficult part of any investigation, we recently developed a dimensionality reduction algorithm, sketch-map, that can be used to build a low-dimensional map of a phase space of high-dimensionality. In this paper we discuss how these machine-generated CVs can be used to accelerate the exploration of phase space and to reconstruct free-energy landscapes. To do so, we develop a formalism in which high-dimensional configurations are no longer represented by low-dimensional position vectors. Instead, for each configuration we calculate a probability distribution, which has a domain that encompasses the entirety of the low-dimensional space. To construct a biasing potential, we exploit an analogy with metadynamics and use the trajectory to adaptively construct a repulsive, history-dependent bias from the distributions that correspond to the previously visited configurations. This potential forces the system to explore more of phase space by making it desirable to adopt configurations whose distributions do not overlap with the bias. We apply this algorithm to a small model protein and succeed in reproducing the free-energy surface that we obtain from a parallel tempering calculation. PMID:22427357
Kandori, Akihiko; Oe, Hiroshi; Miyashita, Kotaro; Ohira, Shinji; Naritomi, Hiroaki; Chiba, Yoshihide; Ogata, Kuniomi; Murakami, Masahiro; Miyashita, Tsuyoshi; Tsukada, Keiji
2003-07-01
The aim of this study was to investigate neural activity during period of vertiginous sensation, induced by caloric stimulation. After caloric vestibular stimulation (CVS) by cold water of five volunteers (n=5, age: 30+/-10), auditory evoked magnetic fields (AEFs) during the subsequent period of vertiginous sensations were measured by magnetoencephalography (MEG). Current-arrow maps (CAMs) were produced to estimate the spatial current distribution of the AEF responses, and a rotation value (dI(rot)) was calculated from the CAM. The worth of the dI(rot) values as indicators of vertigo was evaluated by comparing them with earlier reported values for elderly control (n=11, age: 67+/-5) and chronic dizziness (CD) (n=27, age: 68+/-8) groups (obtained from AEF responses with no the CVS). Although all volunteers felt vertigo during the AEF measurements, the AEF waveforms and CAM pattern only showed slight changes. While the dI(rot) values (1.43+/-0.73) just after CVS were not significantly different from those (1.59+/-0.46) for the elderly controls, they were significantly different from those (3.54+/-1.34) for the CD patients. These findings suggest that (i) the new parameter (dI(rot)) is more sensitively indicates dizziness (non-rotatory sensation) than vertigo (ii) the auditory cortical region may play an important role in body-balance perception of floating sensations.
Retail clinic utilization associated with lower total cost of care.
Sussman, Andrew; Dunham, Lisette; Snower, Kristen; Hu, Min; Matlin, Olga S; Shrank, William H; Choudhry, Niteesh K; Brennan, Troyen
2013-04-01
To better understand the impact of retail clinic use on a patient's annual total cost of care. A propensity score matched-pair, cohort design was used to analyze healthcare spending patterns among CVS Caremark employees in the year following a visit to a MinuteClinic, the retail clinics inside CVS pharmacies. De-identified medical and pharmacy claims for CVS Caremark employees and their dependents who received care at a retail clinic between June 1, 2009, and May 31, 2010, were matched to those of subjects who received care elsewhere. High-dimensional propensity score and greedy matching techniques were used to create a 1-to-1 matched cohort that was analyzed using generalized linear regression models. Individuals using a retail clinic had a lower total cost of care (-$262; 95% confidence interval, -$510 to -$31; P = .025) in the year following their clinic visit than individuals who received care in other settings. This savings was primarily due to lower medical expenses at physicians' offices ($77 savings, P = .008) and hospital inpatient care ($121 savings, P = .049). The 6022 retail clinic users also had 142 (12%) fewer emergency department visits (P = .01), though this was not related to significant cost savings. This study found that retail clinic use was associated with lower overall total cost of care compared with that at alternative sites. Savings may extend beyond the retail clinic visit itself to other types of medical utilization.
Analytical validation of a new point-of-care assay for serum amyloid A in horses.
Schwartz, D; Pusterla, N; Jacobsen, S; Christopher, M M
2018-01-17
Serum amyloid A (SAA) is a major acute phase protein in horses. A new point-of-care (POC) test for SAA (Stablelab) is available, but studies evaluating its analytical accuracy are lacking. To evaluate the analytical performance of the SAA POC test by 1) determining linearity and precision, 2) comparing results in whole blood with those in serum or plasma, and 3) comparing POC results with those obtained using a previously validated turbidimetric immunoassay (TIA). Assay validation. Analytical validation of the POC test was done in accordance with American Society of Veterinary Clinical Pathology guidelines using residual equine serum/plasma and whole blood samples from the Clinical Pathology Laboratory at the University of California-Davis. A TIA was used as the reference method. We also evaluated the effect of haematocrit (HCT). The POC test was linear for SAA concentrations of up to at least 1000 μg/mL (r = 0.991). Intra-assay CVs were 13, 18 and 15% at high (782 μg/mL), intermediate (116 μg/mL) and low (64 μg/mL) concentrations. Inter-assay (inter-batch) CVs were 45, 14 and 15% at high (1372 μg/mL), intermediate (140 μg/mL) and low (56 μg/mL) concentrations. SAA results in whole blood were significantly lower than those in serum/plasma (P = 0.0002), but were positively correlated (r = 0.908) and not affected by HCT (P = 0.261); proportional negative bias was observed in samples with SAA>500 μg/mL. The difference between methods exceeded the 95% confidence interval of the combined imprecision of both methods (15%). Analytical validation could not be performed in whole blood, the sample most likely to be used stall side. The POC test has acceptable accuracy and precision in equine serum/plasma with SAA concentrations of up to at least 1000 μg/mL. Low inter-batch precision at high concentrations may affect serial measurements, and the use of the same test batch and sample type (serum/plasma or whole blood) is recommended. Comparison of results between the POC test and the TIA is not recommended. © 2018 EVJ Ltd.
Santamaria, A R; Antonacci, D; Caruso, G; Cavaliere, C; Gubbiotti, R; Lagana, A; Valletta, A; Pasqua, G
2010-09-01
Cell cultures obtained from Vitis vinifera cvs Michele Palieri and Red Globe were cultured in order to stimulate stilbene production. In the calli, stilbene production peaked at day 22 of culture for both cultivars; the main compound was trans-piceid, followed by cis-piceid. Methyl jasmonate, which was added to cell suspensions in the first half of the exponential growth phase, enhanced stilbene accumulation, producing mainly trans-piceid and epsilon-viniferin. Other stilbenoids, though in lower quantities, were identified by liquid chromatography/positive electrospray mass spectrometry. epsilon-Viniferin and trans-resveratrol were the main compounds released into the culture medium. The total quantity of stilbenes was genotype dependent, with a better response found for the cv Red Globe.
Morishita, Tetsuya; Yonezawa, Yasushige; Ito, Atsushi M
2017-07-11
Efficient and reliable estimation of the mean force (MF), the derivatives of the free energy with respect to a set of collective variables (CVs), has been a challenging problem because free energy differences are often computed by integrating the MF. Among various methods for computing free energy differences, logarithmic mean-force dynamics (LogMFD) [ Morishita et al., Phys. Rev. E 2012 , 85 , 066702 ] invokes the conservation law in classical mechanics to integrate the MF, which allows us to estimate the free energy profile along the CVs on-the-fly. Here, we present a method called parallel dynamics, which improves the estimation of the MF by employing multiple replicas of the system and is straightforwardly incorporated in LogMFD or a related method. In the parallel dynamics, the MF is evaluated by a nonequilibrium path-ensemble using the multiple replicas based on the Crooks-Jarzynski nonequilibrium work relation. Thanks to the Crooks relation, realizing full-equilibrium states is no longer mandatory for estimating the MF. Additionally, sampling in the hidden subspace orthogonal to the CV space is highly improved with appropriate weights for each metastable state (if any), which is hardly achievable by typical free energy computational methods. We illustrate how to implement parallel dynamics by combining it with LogMFD, which we call logarithmic parallel dynamics (LogPD). Biosystems of alanine dipeptide and adenylate kinase in explicit water are employed as benchmark systems to which LogPD is applied to demonstrate the effect of multiple replicas on the accuracy and efficiency in estimating the free energy profiles using parallel dynamics.
Dunstan, R A; Simpson, M B
1985-12-01
We have used fluorescence flow cytometry to analyse cell-to-cell variability in the density of platelet ABH, Ii, Lewis, P, P1A1, Bak,a and HLA class I antigens. Human IgG and IgM antibodies were used in a two-stage assay with goat FITC-conjugated antihuman IgG (H&L) antibody as the label, followed by single cell analysis of 10 000 platelets per sample using a 256-channel fluorescence flow cytometer (Becton-Dickinson FACS Analyser). Computer analysis of fluorescence intensity histograms for mean and peak channel and coefficient of variation shows that the degree of heterogeneity in platelet antigen density varies with each particular blood group. The broad fluorescence distribution curves with oligosaccharide antigens (CVs: A = 53, B = 40, I = 44, Lea = 40, P = 40) indicate that these antigens possess a greater variability in the number of sites per cell compared to the more homogeneous distribution of P1,A1 BaK,a and HLA (CVs: P1A1 = 24, HLA = 30). These findings may partly account for the mechanism by which transfusion of ABO-incompatible platelets results in a biphasic survival curve, with a period of early rapid removal of those platelets with a high density of antigen sites, followed by a relatively normal survival curve for those platelets that possess only a few or no antigen sites. In contrast, P1A1 and HLA sites are less variable in number from one platelet to another in a given donor, and immune-mediated removal would be more likely to approximate a single exponential curve.
Cowpea viruses: Effect of single and mixed infections on symptomatology and virus concentration
Taiwo, Moni A; Kareem, Kehinde T; Nsa, Imade Y; D'A Hughes, Jackies
2007-01-01
Natural multiple viral infections of cultivated cowpeas have been reported in Nigeria. In this study, three Nigerian commercial cowpea cultivars ("Olo 11", "Oloyin" and "White") and two lines from the IITA (IT86D- 719 and TVU 76) were mechanically inoculated with Cowpea aphid-borne mosaic virus (CABMV), Bean southern mosaic virus (SBMV) and Cowpea mottle virus (CMeV) singly, as well as in all possible combinations at 10, 20 and 30 days after planting (DAP). Samples of leaves or stems were collected at 10, 20 and 30 days after inoculation (DAI) and analyzed for relative virus concentration by Enzyme-Linked Immunosrbent Assay. All the cultivars and lines {CVS/L} were susceptible to the viruses but the commercial CVS showed more severe symptoms and had relatively higher viral concentration. In single virus infections, CABMV which induced the most severe symptoms had absorbance values (at 405 nm) of 0.11 to 0.46 while SBMV and CMeV which induced moderate symptoms had virus titre of 0.74 to 1.99 and 0.11 to 0.90 respectively. Plants inoculated 10 DAP had significantly higher virus concentration than those inoculated 30 DAP. In mixed infections involving CABMV (10 DAP) apical necrosis and death were observed in commercial cultivars "Olo 11" and "White". Enhancement of CMeV titers were observed in plants infected with CMeV + CABMV. Multiple viral infections of cowpeas may result in complete yield loss, hence, the availability of seeds of cultivars with a high level of multiple virus resistance is recommended as a means of control. PMID:17900355
40 CFR 86.1519 - CVS calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Otto-Cycle Heavy-Duty Engines, New Methanol-Fueled Natural Gas-Fueled, and Liquefied Petroleum Gas-Fueled Diesel-Cycle Heavy-Duty Engines, New Otto-Cycle Light-Duty Trucks, and New Methanol-Fueled Natural...
Connected motorcycle system performance.
DOT National Transportation Integrated Search
2016-01-15
This project characterized the performance of Connected Vehicle Systems (CVS) on motorcycles based on two key components: global positioning and wireless communication systems. Considering that Global Positioning System (GPS) and 5.9 GHz Dedicated Sh...
American Academy of Dermatology
... Center News Advocacy priorities AADA Health System Reform Principles Drug pricing and availability CVS dermatologic formulary restrictions ... Us Media contacts Advertising contacts AAD logo Advertising, marketing and sponsorships Legal notice Copyright © 2017 American Academy ...
Work Physiology Evaluation of Laundry Workers
NASA Astrophysics Data System (ADS)
Sari, A. D.; Suryoputro, M. R.; Pramaningtyas, M. D.; Putra, P. S.; Maulidyawati, S. B.
2016-01-01
This study aimed to assess cardiovascular strain during laundry operations in terms of physical workload, based on heart rate changes and level of pain complaints. Researchers measured resting and working heart rates and calculated cardiovascular load (%CVL), cardiovascular strain (%CVS), reserve heart rate (%RHR), energy expenditure, oxygen consumption, and measure level of pain complain in 6 laundry workers using Nordic Body Map questionnaire (NBM). Based on the result of %CVL and %CVS, the work in laundry was classified as acceptable level. Similarly, a high-level category was recorded for %RHR in moderate of energy expenditure. However, there are very pain level complain for hand using NBM questionnaire. Thus, there is a need to redesign the work content of equipment used and keep the physical workload in acceptable level, as this will increase their productivity and reduce their health risk.
A search for novae in M 31 globular clusters
NASA Astrophysics Data System (ADS)
Ciardullo, Robin; Tamblyn, Peter; Phillips, A. C.
1990-10-01
By combining a local sky-fitting algorithm with a Fourier point-spread-function matching technique, nova outbursts have been searched for inside 54 of the globular clusters contained on the Ciardullo et al. (1987 and 1990) H-alpha survey frames of M 31. Over a mean effective survey time of about 2.0 years, no cluster exhibited a magnitude increase indicative of a nova explosion. If the cataclysmic variables (CVs) contained within globular clusters are similar to those found in the field, then these data imply that the overdensity of CVs within globulars is at least several times less than that of the high-luminosity X-ray sources. If tidal capture is responsible for the high density of hard binaries within globulars, then the probability of capturing condensed objects inside globular clusters may depend strongly on the mass of the remnant.
NASA Astrophysics Data System (ADS)
Giorgino, Toni
2014-03-01
PLUMED-GUI is an interactive environment to develop and test complex PLUMED scripts within the Visual Molecular Dynamics (VMD) environment. Computational biophysicists can take advantage of both PLUMED’s rich syntax to define collective variables (CVs) and VMD’s chemically-aware atom selection language, while working within a natural point-and-click interface. Pre-defined templates and syntax mnemonics facilitate the definition of well-known reaction coordinates. Complex CVs, e.g. involving reference snapshots used for RMSD or native contacts calculations, can be built through dialogs that provide a synoptic view of the available options. Scripts can be either exported for use in simulation programs, or evaluated on the currently loaded molecular trajectories. Script development takes place without leaving VMD, thus enabling an incremental try-see-modify development model for molecular metrics.
Connected cruise control: modelling, delay effects, and nonlinear behaviour
NASA Astrophysics Data System (ADS)
Orosz, Gábor
2016-08-01
Connected vehicle systems (CVS) are considered in this paper where vehicles exchange information using wireless vehicle-to-vehicle (V2V) communication. The concept of connected cruise control (CCC) is established that allows control design at the level of individual vehicles while exploiting V2V connectivity. Due to its high level of modularity the proposed design can be applied to large heterogeneous traffic systems. The dynamics of a simple CVS is analysed in detail while taking into account nonlinearities in the vehicle dynamics as well as in the controller. Time delays that arise due to intermittencies and packet drops in the communication channels are also incorporated. The results are summarised using stability charts which allow one to select control gains to maintain stability and ensure disturbance attenuation when the delay is below a critical value.
Ye, Yuanyuan; Wang, Wei; Zhao, Haijian; He, Falin; Zhong, Kun; Yuan, Shuai; Wang, Zhiguo
2017-09-01
To investigate the situation of Internal Quality Control (IQC) practice for total cholesterol, triglycerides, HDL-cholesterol and LDL-cholesterol from 2014 to 2016 in laboratories in China and provide improvement measurements. A web-based External Quality Assessment (EQA) system was used to collect IQC data of lipid parameters in laboratories which continuously participated in the national EQA programs in China from 2014 to 2016. Pass rate of the coefficients of variation (CVs) of two level quality controls in four lipid parameters were calculated according to six quality specifications for precision to evaluate the current status of precision level of the four lipid parameters and their change over time in China. 533, 512, 504, and 466 laboratories continuously reported the data of level one for total cholesterol, triglyceride, HDL-cholesterol and LDL-cholesterol, and 212, 210, 208 and 198 laboratories reported the level two, respectively. The percentage of laboratories meeting the quality specification varied based on different criteria. Non-significant change can be found in the pass rate of CVs over time. The number of laboratories using a closed system increased over time, but still only accounted for a small proportion. There is no significant difference in the pass rate of CVs between closed and open systems. Triglycerides currently have a fairly good performance in China. While the performance of laboratories on total cholesterol, HDL-cholesterol and LDL-cholesterol has yet to be improved.
Control aspects of the human cardiovascular-respiratory system under a nonconstant workload.
Calderon, Pio Gabrielle B; Habib, Mustafa; Kappel, Franz; de Los Reyes, Aurelio A
2017-07-01
The human cardiovascular system (CVS) and respiratory system (RS) work together in order to supply oxygen (O 2 ) and other substrates needed for metabolism and to remove carbon dioxide (CO 2 ). Global and local control mechanisms act on the CVS in order to adjust blood flow to the different parts of the body. This, in turn, affects the RS since the amount of O 2 and CO 2 transported, respectively to and away from the tissues depends on the cardiac output and blood flow in both the systemic and pulmonary circuits of the CVS. Local metabolic control is influenced by local concentrations of blood gases affecting systemic resistance, resulting to vasoconstriction/vasodilation. Thus, the exchange of blood gases demands a tight coordination between blood flow and ventilation of the lungs. In this work, a model of the cardiovascular-respiratory system (CVRS) is considered to obtain an optimal control for time-dependent ergometric workloads by using the Euler-Lagrange formulation of the optimal control problem. The essential controls in the CVRS model are variations in the heart rate and alveolar ventilation through which the central nervous system restricts the arterial partial pressure of CO 2 ( [Formula: see text] ) close to 40 mmHg. Further, penalization terms in the cost functional are included to match the metabolic need for O 2 and the metabolic production of CO 2 with O 2 - and CO 2 -transport by blood. Copyright © 2017. Published by Elsevier Inc.
Bali, Jatinder; Navin, Neeraj; Thakur, Bali Renu
2007-01-01
To study the knowledge, attitude and practices (KAP) towards computer vision syndrome prevalent in Indian ophthalmologists and to assess whether 'computer use by practitioners' had any bearing on the knowledge and practices in computer vision syndrome (CVS). A random KAP survey was carried out on 300 Indian ophthalmologists using a 34-point spot-questionnaire in January 2005. All the doctors who responded were aware of CVS. The chief presenting symptoms were eyestrain (97.8%), headache (82.1%), tiredness and burning sensation (79.1%), watering (66.4%) and redness (61.2%). Ophthalmologists using computers reported that focusing from distance to near and vice versa (P =0.006, chi2 test), blurred vision at a distance (P =0.016, chi2 test) and blepharospasm (P =0.026, chi2 test) formed part of the syndrome. The main mode of treatment used was tear substitutes. Half of ophthalmologists (50.7%) were not prescribing any spectacles. They did not have any preference for any special type of glasses (68.7%) or spectral filters. Computer-users were more likely to prescribe sedatives/anxiolytics (P = 0.04, chi2 test), spectacles (P = 0.02, chi2 test) and conscious frequent blinking (P = 0.003, chi2 test) than the non-computer-users. All respondents were aware of CVS. Confusion regarding treatment guidelines was observed in both groups. Computer-using ophthalmologists were more informed of symptoms and diagnostic signs but were misinformed about treatment modalities.
Molecular recognition of DNA by ligands: Roughness and complexity of the free energy profile
NASA Astrophysics Data System (ADS)
Zheng, Wenwei; Vargiu, Attilio Vittorio; Rohrdanz, Mary A.; Carloni, Paolo; Clementi, Cecilia
2013-10-01
Understanding the molecular mechanism by which probes and chemotherapeutic agents bind to nucleic acids is a fundamental issue in modern drug design. From a computational perspective, valuable insights are gained by the estimation of free energy landscapes as a function of some collective variables (CVs), which are associated with the molecular recognition event. Unfortunately the choice of CVs is highly non-trivial because of DNA's high flexibility and the presence of multiple association-dissociation events at different locations and/or sliding within the grooves. Here we have applied a modified version of Locally-Scaled Diffusion Map (LSDMap), a nonlinear dimensionality reduction technique for decoupling multiple-timescale dynamics in macromolecular systems, to a metadynamics-based free energy landscape calculated using a set of intuitive CVs. We investigated the binding of the organic drug anthramycin to a DNA 14-mer duplex. By performing an extensive set of metadynamics simulations, we observed sliding of anthramycin along the full-length DNA minor groove, as well as several detachments from multiple sites, including the one identified by X-ray crystallography. As in the case of equilibrium processes, the LSDMap analysis is able to extract the most relevant collective motions, which are associated with the slow processes within the system, i.e., ligand diffusion along the minor groove and dissociation from it. Thus, LSDMap in combination with metadynamics (and possibly every equivalent method) emerges as a powerful method to describe the energetics of ligand binding to DNA without resorting to intuitive ad hoc reaction coordinates.
Badihian, Negin; Saneian, Hossein; Badihian, Shervin; Yaghini, Omid
2018-01-01
Cyclic vomiting syndrome (CVS) is a common functional gastrointestinal disorder characterized by recurrent episodes of nausea and vomiting. There is no definite treatment for the condition, although some medications are recommended. We aimed to compare the efficacy of amitriptyline and cyproheptadine in prophylactic therapy of CVS. This is a single-blinded randomized clinical trial conducted during 2015-2016 in Isfahan, Iran. Sixty-four children who were 3-15 years old, with a diagnosis of CVS (based on Rome III criteria), were included in the study and were randomly divided into two groups of amitriptyline and cyproheptadine. They were followed for 6 months, looking for frequency and duration of attacks as the primary outcome. The mean monthly frequency of attacks in the last 2 months of the study in the amitriptyline and cyproheptadine group were 0.38±0.55 and 0.59±0.71, respectively (P-value=0.197), after intervention. The mean duration of attacks between amitriptyline and cyproheptadine group were 1.41±2.86 and 1.81±2.22 h, respectively (P-value=0.212). In the amitriptyline group 65.6% of patients reported 100% remission, whereas in the cyproheptadine group 50% reported full remission (P-value=0.206). There was no superiority of one of the medications over the other. We did not find any age-related effect on the efficacy of these medications as well.
Computer vision syndrome and ergonomic practices among undergraduate university students.
Mowatt, Lizette; Gordon, Carron; Santosh, Arvind Babu Rajendra; Jones, Thaon
2018-01-01
To determine the prevalence of computer vision syndrome (CVS) and ergonomic practices among students in the Faculty of Medical Sciences at The University of the West Indies (UWI), Jamaica. A cross-sectional study was done with a self-administered questionnaire. Four hundred and nine students participated; 78% were females. The mean age was 21.6 years. Neck pain (75.1%), eye strain (67%), shoulder pain (65.5%) and eye burn (61.9%) were the most common CVS symptoms. Dry eyes (26.2%), double vision (28.9%) and blurred vision (51.6%) were the least commonly experienced symptoms. Eye burning (P = .001), eye strain (P = .041) and neck pain (P = .023) were significantly related to level of viewing. Moderate eye burning (55.1%) and double vision (56%) occurred in those who used handheld devices (P = .001 and .007, respectively). Moderate blurred vision was reported in 52% who looked down at the device compared with 14.8% who held it at an angle. Severe eye strain occurred in 63% of those who looked down at a device compared with 21% who kept the device at eye level. Shoulder pain was not related to pattern of use. Ocular symptoms and neck pain were less likely if the device was held just below eye level. There is a high prevalence of Symptoms of CVS amongst university students which could be reduced, in particular neck pain and eye strain and burning, with improved ergonomic practices. © 2017 John Wiley & Sons Ltd.
Mass impacts on fuel economies of conventional vs. hybrid electric vehicles.
DOE Office of Scientific and Technical Information (OSTI.GOV)
An, F.; Santini, D. J.; Energy Systems
2004-01-01
The strong correlation between vehicle weight and fuel economy for conventional vehicles (CVs) is considered common knowledge, and the relationship of mass reduction to fuel consumption reduction for conventional vehicles (CVs) is often cited without separating effects of powertrain vs. vehicle body (glider), nor on the ground of equivalent vehicle performance level. This paper challenges the assumption that this relationship is easily summarized. Further, for hybrid electric vehicles (HEVs) the relationship between mass, performance and fuel consumption is not the same as for CVs, and vary with hybrid types. For fully functioning (all wheel regeneration) hybrid vehicles, where battery packmore » and motor(s) have enough power and energy storage, a very large fraction of kinetic energy is recovered and engine idling is effectively eliminated. This paper assesses two important impacts of shifting from conventional to hybrid vehicles in terms of the mass vs. fuel economy relationship - (1) significant improvements in fuel economy with little or no change in mass, and (2) once a switch to hybrid powertrains has been made, the effectiveness of mass reduction in improving fuel economy will be diminished relative to conventional vehicles. In this paper, we discuss vehicle tractive load breakdowns and impacts of hybridization on vehicle efficiency, discuss capture of kinetic energy by conversion to electrical energy via regenerative braking, assess benefits of shutting off the engine when the vehicle does not require power, and investigate energy losses associated with vehicle mass.« less
da Silva, Leila Picolli; Ciocca, Maria de Lourdes Santorio; Furlong, Eliana Badiale
2003-12-01
The precision attributes and use of the enzymatic-gravimetric method of Prosky et al. (1992) (AOAC 985.29) were evaluated using corn (BR 5202 Pampa) and oat (UFRGS 15) samples. The effect of laboratory batches carried out in different days were evaluated in six laboratory batches, using for each material one duplicate for total fiber (FT) determination, one duplicate for insoluble fiber (FI) determination and blank ones for FT and for FI (both in duplicate). In order to characterize repetitive aspects, five other FT and FI determinations added to each sample were evaluated, summing up 11 data. The low coefficients of variation in the first six batches were considered acceptable as an expression of expected total intralaboratory variation. The repetitive of the method was considered good for FT determinations (CVs < 10%). However, in the FI determination a high frequency of negative values of ash and blanks was found, impairing the repetitive aspects evaluation. The magnitude of the total gravimetric corrections varies with the kind of the sample and is especially influenced by the protein content.
Performance evaluation of Abbott CELL-DYN Ruby for routine use.
Lehto, T; Hedberg, P
2008-10-01
CELL-DYN Ruby is a new automated hematology analyzer suitable for routine use in small laboratories and as a back-up or emergency analyzer in medium- to high-volume laboratories. The analyzer was evaluated by comparing the results from the CELL-DYN((R)) Ruby with the results obtained from CELL-DYN Sapphire . Precision, linearity, and carryover between patient samples were also assessed. Precision was good at all levels for the routine cell blood count (CBC) parameters, CV% being
Rh Factor: How It Can Affect Your Pregnancy
... antibodies after a miscarriage , ectopic pregnancy , or induced abortion . If an Rh-negative woman gets pregnant after ... ectopic pregnancy or a first-trimester miscarriage or abortion after invasive procedures, such as amniocentesis, CVS, fetal ...
Transportation planning implications of automated/connected vehicles on Texas highways.
DOT National Transportation Integrated Search
2017-04-01
This research project was focused on the transportation planning implications of automated/connected : vehicles (AV/CVs) on Texas highways. The research assessed how these potentially transformative : technologies can be included in transportation pl...