Experimental optimization of a free vortex propeller runner for micro hydro application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singh, Punit; Nestmann, Franz
2009-09-15
The turbine technology for low head application in the micro hydro range has been vastly neglected despite niche available in scattered regions of valley flows as well as in wastewater canals and other energy recovery schemes, where the available head does not exceed 2 meters. The goal of this study is to develop hydraulically optimized propeller turbines for the micro hydro range with a particular focus on ease of manufacture. This paper presents a wide range of geometrical optimization steps carried out on a propeller runner, whose blades have been designed using the free vortex theory, and operating with amore » gross head from 1.5 to 2 m and discharge of approximately 75 l/s. It further illustrates 3 stages of geometrical modifications carried out on the runner with an objective of optimizing the runner performance. These modifications comprised of changes to the tip angles (both at the runner inlet and exit) as well as the hub angles (at the runner inlet) of the runner blades. The paper also presents an interesting theoretical methodology to analyze the effects of each optimization stage. This method looks at the relative changes to shaft power and discharge at constant head and speed and gives wonderful insight as to how the internal parameters like Euler shaft work and runner hydraulic losses are behaving with respect to each optimization stage. It was found that the performance of the runner was very sensitive to changes to exit tip angle. At two levels of modification, the discharge increased in the range of 15-30%, while shaft power increased in the range of 12-45%, thus influencing the efficiency characteristics. The results of the runner inlet tip modification were very interesting in that a very significant rise of turbine efficiency was recorded from 55% to 74% at the best efficiency point, which was caused by a reduced discharge consumption as well as a higher power generation. It was also found that the optimization study on a propeller runner has reasonably validated the estimates of the free vortex theory despite small deviations. The final runner configuration demonstrated a maximum efficiency of 74% ({+-}1.8%), which is very encouraging from the perspectives of micro hydro application. The paper concludes with recommendations of a series of optimization steps to increase the efficiency of the runner. It also recommends the attempt of Computational Fluid Dynamics both as a validation and optimization tool for future research on propeller runners. (author)« less
Load variation effects on the pressure fluctuations exerted on a Kaplan turbine runner
NASA Astrophysics Data System (ADS)
Amiri, K.; Mulu, B.; Raisee, M.; Cervantes, M. J.
2014-03-01
Introduction of intermittent electricity production systems like wind power and solar systems to electricity market together with the consumption-based electricity production resulted in numerous start/stops, load variations and off-design operation of water turbines. The hydropower systems suffer from the varying loads exerted on the stationary and rotating parts of the turbines during load variations which they are not designed for. On the other hand, investigations on part load operation of single regulated turbines, i.e., Francis and propeller, proved the formation of rotating vortex rope (RVR) in the draft tube. The RVR induces oscillating flow both in plunging and rotating modes which results in oscillating force with two different frequencies on the runner blades, bearings and other rotating parts of the turbine. The purpose of this study is to investigate the effect of transient operations on the pressure fluctuations on the runner and mechanism of the RVR formation/mitigation. Draft tube and runner blades of the Porjus U9 model, a Kaplan turbine, were equipped with pressure sensors. The model was run in off-cam mode during different load variation conditions to check the runner performance under unsteady condition. The results showed that the transients between the best efficiency point and the high load happens in a smooth way while transitions to/from the part load, where rotating vortex rope (RVR) forms in the draft tube induces high level of fluctuations with two frequencies on the runner; plunging and rotating mode of the RVR.
Kaplan turbine tip vortex cavitation - analysis and prevention
NASA Astrophysics Data System (ADS)
Motycak, L.; Skotak, A.; Kupcik, R.
2012-11-01
The work is focused on one type of Kaplan turbine runner cavitation - a tip vortex cavitation. For detailed description of the tip vortex, the CFD analysis is used. On the basis of this analysis it is possible to estimate the intensity of cavitating vortex core, danger of possible blade surface and runner chamber cavitation pitting. In the paper, the ways how to avoid the pitting effect of the tip vortex are described. In order to prevent the blade surface against pitting, the following possibilities as the change of geometry of the runner blade, dimension of tip clearance and finally the installation of the anti-cavitation lips are discussed. The knowledge of the shape and intensity of the tip vortex helps to design the anti-cavitation lips more sophistically. After all, the results of the model tests of the Kaplan runner with or without anti-cavitation lips and the results of the CFD analysis are compared.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singh, Punit; Nestmann, Franz
2010-09-15
A detailed experimental investigation of the effects of exit blade geometry on the part-load performance of low-head, axial flow propeller turbines is presented. Even as these turbines find important applications in small-scale energy generation using micro-hydro, the relationship between the layout of blade profile, geometry and turbine performance continues to be poorly characterized. The experimental results presented here help understand the relationship between exit tip angle, discharge through the turbine, shaft power, and efficiency. The modification was implemented on two different propeller runners and it was found that the power and efficiency gains from decreasing the exit tip angle couldmore » be explained by a theoretical model presented here based on classical theory of turbomachines. In particular, the focus is on the behaviour of internal parameters like the runner loss coefficient, relative flow angle at exit, mean axial flow velocity and net tangential flow velocity. The study concluded that the effects of exit tip modification were significant. The introspective discussion on the theoretical model's limitation and test facility suggests wider and continued experimentation pertaining to the internal parameters like inlet vortex profile and exit swirl profile. It also recommends thorough validation of the model and its improvement so that it can be made capable for accurate characterization of blade geometric effects. (author)« less
Dynamic Runner Forces and Pressure Fluctuations on the Draft Tube Wall of a Model Pump-Turbine
NASA Astrophysics Data System (ADS)
Kirschner, O.; Ruprecht, A.; Göde, E.; Riedelbauch, S.
2016-11-01
When Francis-turbines and pump-turbines operate at off-design conditions, typically a vortex rope develops. The vortex rope causes pressure oscillations leading to fluctuations of the forces affecting the runner. The presence of dynamic runner forces over a long period of time might damage the bearings and possibly the runner. In this experimental investigation, the fluctuating part of the runner forces and the pressure oscillations on the draft tube wall were measured on a model pump-turbine with a simplified straight cone draft tube in different operating conditions. The investigation focuses on the correlation of the pressure fluctuations frequency measured at the draft tube wall with the frequency of the fluctuating forces on the runner. The comparison between pressure fluctuations and dynamic forces shows a significant correlation in all operating points. For the comparison of different components in the spatial directions of the forces, the pressure fluctuations were separated in a synchronous part and a rotating part for operating points with higher amplitudes. The rotating pressure fluctuations correlate with the radial forces especially in the operating points with a rotating vortex rope. At frequencies with higher amplitudes in the pressure fluctuations caused by the vortex rope movement, there are also higher amplitudes in the radial forces at the same frequencies.
Influence of the Runner Gap on the Flow Field in the Draft Tube of a Low Head Turbine
NASA Astrophysics Data System (ADS)
Junginger, Bernd; Riedelbauch, Stefan
2016-11-01
The gap flow of axial turbines is usually neglected in the design process of hydraulic machines, although it can lead to a stabilization of the draft tube flow. Though, this negligence of the gap can falsify the flow field in the draft tube. Presented in this paper are simulations of an axial propeller turbine operated at Δγ = Δγ BEP with Q > Qbep . Simulations of four gap sizes, using a mesh with about 15 million elements for the entire machine, are performed. Additionally, two turbulence models are applied, the k-ω-SST and the SAS-SST model. At the evaluated operating point a full load vortex develops. Depending on the turbulence model the developing vortex rope can either arise from the hub in a straight shape or in a shape resembling a corkscrew. Integral quantities such as head and torque are compared with experimental model test results performed in the laboratory of the Institute. Flow field simulation results are evaluated for different gap widths. Furthermore, the impact of the gap flow respectively the gap size can be observed in velocity profiles evaluated at different positions downstream the runner until to the end of the draft tube cone. Moreover, the pressure signals recorded at the beginning of the draft tube cone are also affected by the gap flow.
Arndt, R; Pennings, P; Bosschers, J; van Terwisga, T
2015-10-06
Marine propellers display several forms of cavitation. Of these, propeller-tip vortex cavitation is one of the important factors in propeller design. The dynamic behaviour of the tip vortex is responsible for hull vibration and noise. Thus, cavitation in the vortices trailing from tips of propeller blades has been studied extensively. Under certain circumstances cavitating vortices have been observed to have wave-like disturbances on the surfaces of vapour cores. Intense sound at discrete frequencies can result from a coupling between tip vortex disturbances and oscillating sheet cavitation on the surfaces of the propeller blades. This research article focuses on the dynamics of vortex cavitation and more in particular on the energy and frequency content of the radiated pressures.
Arndt, R.; Pennings, P.; Bosschers, J.; van Terwisga, T.
2015-01-01
Marine propellers display several forms of cavitation. Of these, propeller-tip vortex cavitation is one of the important factors in propeller design. The dynamic behaviour of the tip vortex is responsible for hull vibration and noise. Thus, cavitation in the vortices trailing from tips of propeller blades has been studied extensively. Under certain circumstances cavitating vortices have been observed to have wave-like disturbances on the surfaces of vapour cores. Intense sound at discrete frequencies can result from a coupling between tip vortex disturbances and oscillating sheet cavitation on the surfaces of the propeller blades. This research article focuses on the dynamics of vortex cavitation and more in particular on the energy and frequency content of the radiated pressures. PMID:26442147
Runner hub construction for propeller type turbine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eyster, P.J.; Yanek, E.J.
1976-08-10
A runner hub is described for a propeller type hydraulic turbine wherein the hub is constructed of at least a pair of arcuate segments. When the arcuate segments are assembled together, they form a hollow hub. Turnbuckles are provided within the hub attached to opposite hub segments and are adjustable to forcibly hold the hub segments in the assembled position.
NASA Astrophysics Data System (ADS)
Goyal, Rahul; Trivedi, Chirag; Kumar Gandhi, Bhupendra; Cervantes, Michel J.
2017-07-01
Hydraulic turbines are operated over an extended operating range to meet the real time electricity demand. Turbines operated at part load have flow parameters not matching the designed ones. This results in unstable flow conditions in the runner and draft tube developing low frequency and high amplitude pressure pulsations. The unsteady pressure pulsations affect the dynamic stability of the turbine and cause additional fatigue. The work presented in this paper discusses the flow field investigation of a high head model Francis turbine at part load: 50% of the rated load. Numerical simulation of the complete turbine has been performed. Unsteady pressure pulsations in the vaneless space, runner, and draft tube are investigated and validated with available experimental data. Detailed analysis of the rotor stator interaction and draft tube flow field are performed and discussed. The analysis shows the presence of a rotating vortex rope in the draft tube at the frequency of 0.3 times of the runner rotational frequency. The frequency of the vortex rope precession, which causes severe fluctuations and vibrations in the draft tube, is predicted within 3.9% of the experimental measured value. The vortex rope results pressure pulsations propagating in the system whose frequency is also perceive in the runner and upstream the runner.
Numerical study of vortex rope during load rejection of a prototype pump-turbine
NASA Astrophysics Data System (ADS)
Liu, J. T.; Liu, S. H.; Sun, Y. K.; Wu, Y. L.; Wang, L. Q.
2012-11-01
A transient process of load rejection of a prototype pump-turbine was studied by three dimensional, unsteady simulations, as well as steady calculations.Dynamic mesh (DM) method and remeshing method were used to simulate the rotation of guide vanes and runner. The rotational speed of the runner was predicted by fluid couplingmethod. Both the transient calculation and steady calculation were performed based on turbulence model. Results show that steady calculation results have large error in the prediction of the external characteristics of the transient process. The runaway speed can reach 1.15 times the initial rotational speed during the transient process. The vortex rope occurs before the pump-turbine runs at zero moment point. Vortex rope has the same rotating direction with the runner. The vortex rope is separated into two parts as the flow rate decreases to 0. Pressure level decreases during the whole transient process.The transient simulation result were also compared and verified by experimental results. This computational method could be used in the fault diagnosis of transient operation, as well as the optimization of a transient process.
Effect of vortex inlet mode on low-power cylindrical Hall thruster
NASA Astrophysics Data System (ADS)
Ding, Yongjie; Jia, Boyang; Xu, Yu; Wei, Liqiu; Su, Hongbo; Li, Peng; Sun, Hezhi; Peng, Wuji; Cao, Yong; Yu, Daren
2017-08-01
This paper examines a new propellant inlet mode for a low-power cylindrical Hall thruster called the vortex inlet mode. This new mode makes propellant gas diffuse in the form of a circumferential vortex in the discharge channel of the thruster. Simulation and experimental results show that the neutral gas density in the discharge channel increases upon the application of the vortex inlet mode, effectively extending the dwell time of the propellant gas in the channel. According to the experimental results, the vortex inlet increases the propellant utilization of the thruster by 3.12%-8.81%, thrust by 1.1%-53.5%, specific impulse by 1.1%-53.5%, thrust-to-power ratio by 10%-63%, and anode efficiency by 1.6%-7.3%, greatly improving the thruster performance.
Forward rotor vortex effects on counter rotating propeller noise
NASA Technical Reports Server (NTRS)
Laur, Michele; Squires, Becky; Nagel, Robert T.
1992-01-01
Three configurations of a model counter rotating propeller manipulate the blade tip flow by: placing the CRP at angle of attack, installing shrouds, and turning the upstream blades to provide forward sweep. Flow visualization and flow measurements with thermal anemometry show no evidence of a tip vortex; however, a leading edge vortex was detected on aft swept blades. The modifications served to alter the strength and/or path of the leading edge vortex. The vortical flow is eliminated by forward sweep on the upstream propeller blades. Far field acoustic data from each test indicate only small influences on the level and directivity of the BPFs. The interaction tone at the sum of the two BPF's was significantly altered in a consistent manner. As the vortex system varied, the interaction tone was affected: far field noise levels in the forward quandrant increased and the characteristic noise minimum near the plane of rotation became less pronounced and in some cases were eliminated. If the forward propeller leading edge vortex system does not impact the rear propeller in the standard manner, a net increase in the primary interaction tone occurs for the model tested. If the leading edge vortex is removed, the interaction tone increases.
Unsteady hydraulic simulation of the cavitating part load vortex rope in Francis turbines
NASA Astrophysics Data System (ADS)
Brammer, J.; Segoufin, C.; Duparchy, F.; Lowys, P. Y.; Favrel, A.; Avellan, F.
2017-04-01
For Francis turbines at part load operation a helical vortex rope is formed due to the swirling nature of the flow exiting the runner. This vortex creates pressure fluctuations which can lead to power swings, and the unsteady loading can lead to fatigue damage of the runner. In the case that the vortex rope cavitates there is the additional risk that hydro-acoustic resonance can occur. It is therefore important to be able to accurately simulate this phenomenon to address these issues. In this paper an unsteady, multi-phase CFD model was used to simulate two part-load operating points, for two different cavitation conditions. The simulation results were validated with test-rig data, and showed very good agreement. These results also served as an input for FEA calculations and fatigue analysis, which are presented in a separate study.
Evaluation of Impinging Stream Vortex Chamber Concepts for Liquid Rocket Engine Applications
NASA Technical Reports Server (NTRS)
Trinh, Huu P.; Bullard, Brad; Kopicz, Charles; Michaels, Scott; Turner, James (Technical Monitor)
2001-01-01
To pursue technology developments for future launch vehicles, NASA/Marshall Space Flight Center (MSFC) is examining vortex chamber concepts for liquid rocket engine applications. Past studies indicated that the vortex chamber schemes potentially have a number of advantages over conventional chamber methods. Due to the nature of the vortex flow, relatively cooler propellant streams tend to flow along the chamber wall. Hence, the thruster chamber can be operated without the need of any cooling techniques. This vortex flow also creates strong turbulence, which promotes the propellant mixing process. Consequently, the subject chamber concepts not only offer the system simplicity, but they also would enhance the combustion performance. The test results showed that the chamber performance was markedly high even at a low chamber length-to-diameter ratio (L/D). This incentive can be translated to a convenience in the thrust chamber packaging. Variations of the vortex chamber concepts have been introduced in the past few decades. These investigations include an ongoing work at Orbital Technologies Corporation (ORBITEC). By injecting the oxidizer tangentially at the chamber convergence and fuel axially at the chamber head end, Knuth et al. were able to keep the wall relatively cold. A recent investigation of the low L/D vortex chamber concept for gel propellants was conducted by Michaels. He used both triplet (two oxidizer and one fuel orifices) and unlike impinging schemes to inject propellants tangentially along the chamber wall. Michaels called the subject injection scheme as Impinging Stream Vortex Chamber (ISVC). His preliminary tests showed that high performance, with an Isp efficiency of 92%, can be obtained. MSFC and the U.S. Army are jointly investigating an application of the ISVC concept for the cryogenic oxygen/hydrocarbon propellant system. This vortex chamber concept is currently tested with gel propellants at AMCOM at Redstone Arsenal, Alabama. A version of this concept for the liquid oxygen (LOX)/hydrocarbon fuel (RPM) system has been derived from the one for the gel propellant.
Computation of the tip vortex flowfield for advanced aircraft propellers
NASA Technical Reports Server (NTRS)
Tsai, Tommy M.; Dejong, Frederick J.; Levy, Ralph
1988-01-01
The tip vortex flowfield plays a significant role in the performance of advanced aircraft propellers. The flowfield in the tip region is complex, three-dimensional and viscous with large secondary velocities. An analysis is presented using an approximate set of equations which contains the physics required by the tip vortex flowfield, but which does not require the resources of the full Navier-Stokes equations. A computer code was developed to predict the tip vortex flowfield of advanced aircraft propellers. A grid generation package was developed to allow specification of a variety of advanced aircraft propeller shapes. Calculations of the tip vortex generation on an SR3 type blade at high Reynolds numbers were made using this code and a parametric study was performed to show the effect of tip thickness on tip vortex intensity. In addition, calculations of the tip vortex generation on a NACA 0012 type blade were made, including the flowfield downstream of the blade trailing edge. Comparison of flowfield calculations with experimental data from an F4 blade was made. A user's manual was also prepared for the computer code (NASA CR-182178).
Evaluation of Impinging Stream Vortex Chamber Concepts for Liquid Rocket Engine Applications
NASA Technical Reports Server (NTRS)
Trinh, Huu; Kopicz, Charles; Bullard, Brad; Michaels, Scott
2003-01-01
NASA Marshall Space Flight Center (MSFC) and the U. S. Army are jointly investigating vortex chamber concepts for cryogenic oxygen/hydrocarbon fuel rocket engine applications. One concept, the Impinging Stream Vortex Chamber Concept (ISVC), has been tested with gel propellants at AMCOM at Redstone Arsenal, Alabama. A version of this concept for the liquid oxygen (LOX)/hydrocarbon fuel (RP-1) propellant system is derived from the one for the gel propellant. An unlike impinging injector is employed to deliver the propellants to the chamber. MSFC has also designed two alternative injection schemes, called the chasing injectors, associated with this vortex chamber concept. In these injection techniques, both propellant jets and their impingement point are in the same chamber cross-sectional plane. One injector has a similar orifice size with the original unlike impinging injector. The second chasing injector has small injection orifices. The team has achieved their objectives of demonstrating the self-cooled chamber wall benefits of ISVC and of providing the test data for validating computational fluids dynamics (CFD) models. These models, in turn, will be used to design the optimum vortex chambers in the future.
Observations of tip vortex cavitation inception from a model marine propeller
NASA Astrophysics Data System (ADS)
Lodha, R. K.; Arakeri, V. H.
1984-01-01
Cavitation inception characteristics of a model marine propeller having three blades, developed area ratio of 0.34 and at three different pitch to diameter ratios of 0.62, 0.83 and 1.0 are reported. The dominant type of cavitation observed at inception was the tip vortex type. The measured magnitude of inception index is found to agree well with a proposed correlation due to Strasberg. Performance calculations of the propeller based on combined vortex and blade element theory are also presented.
Vortex rope instabilities in a model of conical draft tube
NASA Astrophysics Data System (ADS)
Skripkin, Sergey; Tsoy, Mikhail; Kuibin, Pavel; Shtork, Sergey
2017-10-01
We report on experimental studies of the formation of vortex ropes in a laboratory simplified model of hydroturbine draft tube. Work is focused on the observation of various flow patterns at the different rotational speed of turbine runner at fixed flow rate. The measurements involve high-speed visualization and pressure pulsations recordings. Draft tube wall pressure pulsations are registered by pressure transducer for different flow regimes. Vortex rope precession frequency were calculated using FFT transform. The experiments showed interesting features of precessing vortex rope like twin spiral and formation of vortex ring.
NASA Astrophysics Data System (ADS)
Houde, S.; Fraser, R.; Ciocan, G. D.; Deschênes, C.
2012-11-01
A good evaluation of the unsteady pressure field on hydraulic turbine blades is critical in evaluating the turbine lifespan and its maintenance schedule. Low-head turbines such as Kaplan and Propeller, using a relatively low number of blades supported only at the hub, may also undergo significant deflections at the blade tips which will lead to higher amplitude vibration compared to Francis turbines. Furthermore, the precise evaluation of the unsteady pressure distribution on low-head turbines is still a challenge for computational fluid dynamics (CFD). Within the framework of an international research consortium on low-head turbines, a research project was instigated at the Hydraulic Machines Laboratory in Laval University (LAMH) to perform experimental measurements of the unsteady pressure field on propeller turbine model runner blades. The main objective of the project was to measure the pressure fluctuations on a wide band of frequencies, both in a blade-to-blade channel and on the pressure and suction side of the same blade, to provide validation data for CFD computations. To do so, a 32 channels telemetric data transmission system was used to extract the signal of 31 pressure transducers and two strain gages from the rotating part at an acquisition frequency of 5 KHz. The miniature piezoelectric pressure transducers were placed on two adjacent runner blades according to an estimated pressure distribution coming from flow simulations. Two suction sides and one pressure side were instrumented. The strain gages were mounted in full-bridge on both pressure and suction sides to measure the blade span wise deflection. In order to provide boundary conditions for flow simulations, the test bench conditions during the measurements were acquired. The measurements were made in different operating conditions ranging from part load, where a cavitating vortex occurs, to full load under different heads. The results enabled the identification and the quantification of the major known sources of pressure fluctuation as well as some unexpected ones. The paper first presents the experimental methodology discussing relevant topics such as telemetric system setup, transducers calibration and errors analysis. The main results are then presented to illustrate the relative amplitude of the main source of pressure fluctuations under different operating conditions. The discussion and conclusion addresses the important observations stemming from the data analysis and illustrates that most of the results can be correlated with the known behavior of hydraulic turbines while some require further investigation.
Research on the statically thrusting propeller
NASA Technical Reports Server (NTRS)
Eisenhuth, J. J.
1978-01-01
Methods for calculating the induced flow at propeller blades were analyzed by treating the wake formation as an initial problem in time. An unsteady vortex lattice technique was applied to the wake formation and the vortex core size was studied.
A generalized vortex theory of the screw propeller and its application
NASA Technical Reports Server (NTRS)
Reissner, Hans
1940-01-01
The vortex theory as presented by the author in earlier papers has been extended to permit the solution of the following problems: (1) the investigation of the relation between thrusts and torque distribution and energy loss as given by the induction of helical vortex sheets and by the parasite drag; (2) the checking of the theorem of Betz of the rigidly behaving helical vortex sheet of minimum induced energy loss; (3) the extension of the theory of the screw propeller of minimum energy loss for the inclusion of parasite-drag distribution along the blades. A simple system of diagrams has been developed to systematize the design of airplane propellers for a wide range of parasite-drag distribution along the blades.
User's manual for PEPSIG NASA tip vortex version
NASA Technical Reports Server (NTRS)
Tsai, Tommy M.; Dejong, Frederick J.; Levy, Ralph
1988-01-01
The tip vortex flowfield plays a significant role in the performance of advanced aircraft propellers. The flowfield in the tip region is complex, three-dimensional and viscous with large secondary velocities. A computer code was developed to predict the tip vortex flowfield of advanced aircraft propellers. This document is the user's manual. The analysis and a series of test cases are presented in NASA-CR-182179.
Evaluation of Impinging Stream Vortex Chamber Concepts for Liquid Rocket Engine Applications
NASA Technical Reports Server (NTRS)
Trinh, Huu P.; Bullard, Brad; Kopicz, Charles; Michaels, Scott
2002-01-01
To pursue technology developments for future launch vehicles, NASA/Marshall Space Flight Center (MSFC) is examining vortex chamber concepts for liquid rocket engine applications. Past studies indicated that the vortex chamber schemes potentially have a number of advantages over conventional chamber methods. Due to the nature of the vortex flow, relatively cooler propellant streams tend to flow along the chamber wall. Hence, the thruster chamber can be operated without the need of any cooling techniques. This vortex flow also creates strong turbulence, which promotes the propellant mixing process. Consequently, the subject chamber concepts not only offer system simplicity, but also enhance the combustion performance. Test results have shown that chamber performance is markedly high even at a low chamber length-to-diameter ratio (LD). This incentive can be translated to a convenience in the thrust chamber packaging. Variations of the vortex chamber concepts have been introduced in the past few decades. These investigations include an ongoing work at Orbital Technologies Corporation (ORBITEC). By injecting the oxidizer tangentially at the chamber convergence and fuel axially at the chamber head end, Knuth et al. were able to keep the wall relatively cold. A recent investigation of the low L/D vortex chamber concept for gel propellants was conducted by Michaels. He used both triplet (two oxidizer orifices and one fuel orifice) and unlike impinging schemes to inject propellants tangentially along the chamber wall. Michaels called the subject injection scheme an Impinging Stream Vortex Chamber (ISVC). His preliminary tests showed that high performance, with an Isp efficiency of 9295, can be obtained. MSFC and the U. S. Army are jointly investigating an application of the ISVC concept for the cryogenic oxygen/hydrocarbon propellant system. This vortex chamber concept is currently tested with gel propellants at AMCOM at Redstone Arsenal, Alabama. A version of this concept for the liquid oxygen (LOX) hydrocarbon fuel (RP-1) system has been derived from the one for the gel propellant. An unlike impinging injector was employed to deliver the propellants to the chamber. MSFC is also conducting an alternative injection scheme, called the chasing injector, associated with this vortex chamber concept. In this injection technique, both propellant jets and their impingement point are in the same chamber cross-sectional plane. Long duration tests (approximately up to 15 seconds) will be conducted on the ISVC to study the thermal effects. This paper will report the progress of the subject efforts at NASA Marshall Space Flight Center. Thrust chamber performance and thermal wall compatibility will be evaluated. The chamber pressures, wall temperatures, and thrust will be measured as appropriate. The test data will be used to validate CFD models, which, in turn, will be used to design the optimum vortex chambers. Measurements in the previous tests showed that the chamber pressures vary significantly with radius. This is due to the existence of the vortices in the chamber flow field. Hence, the combustion efficiency may not be easily determined from chamber pressure. For this project, measured thrust data will be collected. The performance comparison will be in terms of specific impulse efficiencies. In addition to the thrust measurements, several pressure and temperature readings at various locations on the chamber head faceplate and the chamber wall will be made. The first injector and chamber were designed and fabricated based on the available data and experience gained during gel propellant system tests by the U.S. Army. The alternate injector for the ISVC was also fabricated. Hot-fire tests of the vortex chamber are about to start and are expected to complete in February of 2003 at the TS115 facility of MSFC.
Experimental framework to study tip vortex interactions in multirotor wakes
NASA Astrophysics Data System (ADS)
Yao, Rongnan; Araya, Daniel
2017-11-01
We present an experimental study to compare the dynamic characteristics of tip vortices shed from a propeller in a crossflow to similar characteristics of an isolated vortex column generated in a closed system. Our aim is to evaluate the feasibility of using this simple isolated system to study the more complicated three-dimensional vortex interactions inherent to multirotor wakes, where the local unsteadiness generated by one rotor can strongly impact the performance of nearby rotors. Time-resolved particle image velocimetry is used to measure the velocity field of the propeller wake flow in a wind tunnel and the vortex column in a water tank. Specific attention is placed on analyzing the observed vortex core precession in the isolated system and comparing this to characteristic tip-vortex wandering phenomenon.
On the upper part load vortex rope in Francis turbine: Experimental investigation
NASA Astrophysics Data System (ADS)
Nicolet, C.; Zobeiri, A.; Maruzewski, P.; Avellan, F.
2010-08-01
The swirling flow developing in Francis turbine draft tube under part load operation leads to pressure fluctuations usually in the range of 0.2 to 0.4 times the runner rotational frequency resulting from the so-called vortex breakdown. For low cavitation number, the flow features a cavitation vortex rope animated with precession motion. Under given conditions, these pressure fluctuations may lead to undesirable pressure fluctuations in the entire hydraulic system and also produce active power oscillations. For the upper part load range, between 0.7 and 0.85 times the best efficiency discharge, pressure fluctuations may appear in a higher frequency range of 2 to 4 times the runner rotational speed and feature modulations with vortex rope precession. It has been pointed out that for this particular operating point, the vortex rope features elliptical cross section and is animated of a self-rotation. This paper presents an experimental investigation focusing on this peculiar phenomenon, defined as the upper part load vortex rope. The experimental investigation is carried out on a high specific speed Francis turbine scale model installed on a test rig of the EPFL Laboratory for Hydraulic Machines. The selected operating point corresponds to a discharge of 0.83 times the best efficiency discharge. Observations of the cavitation vortex carried out with high speed camera have been recorded and synchronized with pressure fluctuations measurements at the draft tube cone. First, the vortex rope self rotation frequency is evidenced and the related frequency is deduced. Then, the influence of the sigma cavitation number on vortex rope shape and pressure fluctuations is presented. The waterfall diagram of the pressure fluctuations evidences resonance effects with the hydraulic circuit. The time evolution of the vortex rope volume is compared with pressure fluctuations time evolution using image processing. Finally, the influence of the Froude number on the vortex rope shape and the associated pressure fluctuations is analyzed by varying the rotational speed.
NASA Astrophysics Data System (ADS)
Yamamoto, K.; Müller, A.; Favrel, A.; Avellan, F.
2017-10-01
Francis turbines are subject to various types of cavitation flow depending on the operating condition. To enable a smooth integration of the renewable energy sources, hydraulic machines are now increasingly required to extend their operating range, especially down to extremely low discharge conditions called deep part load operation. The inter-blade cavitation vortex is a typical cavitation phenomenon observed at deep part load operation. However, its dynamic characteristics are insufficiently understood today. In an objective of revealing its characteristics, the present study introduces a novel visualization technique with instrumented guide vanes embedding the visualization devices, providing unprecedented views on the inter-blade cavitation vortex. The binary image processing technique enables the successful evaluation of the inter-blade cavitation vortex in the images. As a result, it is shown that the probability of the inter-blade cavitation development is significantly high close to the runner hub. Furthermore, the mean vortex line is calculated and the vortex region is estimated in the three-dimensional domain for the comparison with numerical simulation results. In addition, the on-board pressure measurements on a runner blade is conducted, and the influence of the inter-blade vortex on the pressure field is investigated. The analysis suggests that the presence of the inter-blade vortex can magnify the amplitude of pressure fluctuations especially on the blade suction side. Furthermore, the wall pressure difference between pressure and suction sides of the blade features partially low or negative values near the hub at the discharge region where the inter-blade vortex develops. This negative pressure difference on the blade wall suggests the development of a backflow region caused by the flow separation near the hub, which is closely related to the development of the inter-blade vortex. The development of the backflow region is confirmed by the numerical simulation, and the physical mechanisms of the inter-blade vortex development is, furthermore, discussed.
NASA Astrophysics Data System (ADS)
Yamamoto, K.; Müller, A.; Favrel, A.; Landry, C.; Avellan, F.
2016-11-01
Francis turbines are subject to various types of the cavitation flow depending on the operating conditions. In order to compensate for the stochastic nature of renewable energy sources, it is more and more required to extend the operating range of the generating units, from deep part load to full load conditions. In the deep part load condition, the formation of cavitation vortices in the turbine blade to blade channels called inter-blade cavitation vortex is often observed. The understanding of the dynamic characteristics of these inter-blade vortices and their formation mechanisms is of key importance in an effort of developing reliable flow simulation tools. This paper reports the numerical and experimental investigations carried out in order to establish the vortex characteristics, especially the inception and the development of the vortex structure. The unsteady RANS simulation for the multiphase flow is performed with the SST- SAS turbulence model by using the commercial flow solver ANSYS CFX. The simulation results in terms of the vortex structure and the cavitation volume are evaluated by comparing them to the flow visualizations of the blade channel acquired through a specially instrumented guide vane as well as from the downstream of the runner across the draft tube cone. The inter-blade cavitation vortex is successfully captured by the simulation and both numerical and experimental results evidence that the inter-blade vortices are attached to the runner hub.
NASA Astrophysics Data System (ADS)
Larrabee, E. E.
1980-07-01
Marine and air screw propellers are considered in terms of theoretical hydrodynamics as developed by Joukowsky, Prandtl, and Betz. Attention is given to the flow around wings of finite span where spanwise flow exists and where lift and the bound vorticity must all go smoothly to zero at the wing tips. The concept of a trailing vortex sheet made up of infinitesimal line vortexes roughly aligned with the direction of flight is discussed in this regard. Also considered is induced velocity, which tends to convect the sheet downward at every stage in the roll-up process, the vortex theory of propellers and the Betz-Prandtl circulation distribution. The performance of the Gossamer Albatross and of a pedal-driven biplane called the Chrysalis are also discussed.
NASA Technical Reports Server (NTRS)
Squires, Becky
1993-01-01
The leading edge vortex of a counter rotating propeller (CRP) model was altered by using shrouds and by turning the upstream rotors to a forward sweep configuration. Performance, flow, and acoustic data were used to determine the effect of vortex impingement on the noise signature of the CRP system. Forward sweep was found to eliminate the leading edge vortex of the upstream blades. Removal of the vortex had little effect on the tone noise at the forward and rear blade passing frequencies (BPF's) but significantly altered both the sound pressure level and directivity of the interaction tone which occurs at the sum of the two BPF's. A separate manipulation of the leading edge vortex performed by installing shrouds of various inlet length on the CRP verified that diverting the vortex path increases the noise level of the interaction tone. An unexpected link has been established between the interaction tone and the leading edge vortex-blade interaction phenomenon.
A Numerical Study of Cavitation Inception in Complex Flow Fields
2007-12-01
field in a tip vortex flow of an open propeller to better describe the interaction between the blade wake and the tip vortex (i.e. the roll-up... WAKE INTERACTION ON CAVITATION INCEPTION IN AN OPEN PROPELLER ................15 2.5 NON-SPHERICAL BUBBLE EFFECTS ON CAVITATION INCEPTION [14,15...18 2.6 STUDY OF CAVITATION INCEPTION NOISE [16,17,18
Evaluation of Vortex Chamber Concepts for Liquid Rocket Engine Applications
NASA Technical Reports Server (NTRS)
Trinh, Huu Phuoc; Knuth, Williams; Michaels, Scott; Turner, James E. (Technical Monitor)
2000-01-01
Rocket-based combined-cycle engines (RBBC) being considered at NASA for future generation launch vehicles feature clusters of small rocket thrusters as part of the engine components. Depending on specific RBBC concepts, these thrusters may be operated at various operating conditions including power level and/or propellant mixture ratio variations. To pursue technology developments for future launch vehicles, NASA/Marshall Space Flight Center (MSFC) is examining vortex chamber concepts for the subject cycle engine application. Past studies indicated that the vortex chamber schemes potentially have a number of advantages over conventional chamber methods. Due to the nature of the vortex flow, relatively cooler propellant streams tend to flow along the chamber wall. Hence, the thruster chamber can be operated without the need of any cooling techniques. This vortex flow also creates strong turbulence, which promotes the propellant mixing process. Consequently, the subject chamber concepts not only offer the system simplicity but they also would enhance the combustion performance. The test results showed that the chamber performance was markedly high even at a low chamber length-to- diameter ratio (L/D). This incentive can be translated to a convenience in the thrust chamber packaging.
Numerical investigation of tip clearance cavitation in Kaplan runners
NASA Astrophysics Data System (ADS)
Nikiforova, K.; Semenov, G.; Kuznetsov, I.; Spiridonov, E.
2016-11-01
There is a gap between the Kaplan runner blade and the shroud that makes for a special kind of cavitation: cavitation in the tip leakage flow. Two types of cavitation caused by the presence of clearance gap are known: tip vortex cavitation that appears at the core of the rolled up vortex on the blade suction side and tip clearance cavitation that appears precisely in the gap between the blade tip edge and the shroud. In the context of this work numerical investigation of the model Kaplan runner has been performed taking into account variable tip clearance for several cavitation regimes. The focus is put on investigation of structure and origination of mechanism of cavitation in the tip leakage flow. Calculations have been performed with the help of 3-D unsteady numerical model for two-phase medium. Modeling of turbulent flow in this work has been carried out using full equations of Navier-Stokes averaged by Reynolds with correction for streamline curvature and system rotation. For description of this medium (liquid-vapor) simplification of Euler approach is used; it is based on the model of interpenetrating continuums, within the bounds of this two- phase medium considered as a quasi-homogeneous mixture with the common velocity field and continuous distribution of density for both phases. As a result, engineering techniques for calculation of cavitation conditioned by existence of tip clearance in model turbine runner have been developed. The detailed visualization of the flow was carried out and vortex structure on the suction side of the blade was reproduced. The range of frequency with maximum value of pulsation was assigned and maximum energy frequency was defined; it is based on spectral analysis of the obtained data. Comparison between numerical computation results and experimental data has been also performed. The location of cavitation zone has a good agreement with experiment for all analyzed regimes.
2003-04-01
This photograph depicts one of over thirty tests conducted on the Vortex Combustion Chamber Engine at Marshall Space Flight Center's (MSFC) test stand 115, a joint effort between NASA's MSFC and the U.S. Army AMCOM of Redstone Arsenal. The engine tests were conducted to evaluate an irnovative, "self-cooled", vortex combustion chamber, which relies on tangentially injected propellants from the chamber wall producing centrifugal forces that keep the relatively cold liquid propellants near the wall.
A Family of Vortices to Study Axisymmetric Vortex Breakdown and Reconnection
NASA Technical Reports Server (NTRS)
Young, Larry A.
2007-01-01
A new analytic model describing a family of vortices has been developed to study some of the axisymmetric vortex breakdown and reconnection fluid dynamic processes underlying body-vortex interactions that are frequently manifested in rotorcraft and propeller-driven fixed-wing aircraft wakes. The family of vortices incorporates a wide range of prescribed initial vorticity distributions -- including single or dual-core vorticity distributions. The result is analytical solutions for the vorticity and velocities for each member of the family of vortices. This model is of sufficient generality to further illustrate the dependence of vortex reconnection and breakdown on initial vorticity distribution as was suggested by earlier analytical work. This family of vortices, though laminar in nature, is anticipated to provide valuable insight into the vortical evolution of large-scale rotor and propeller wakes.
NASA Astrophysics Data System (ADS)
Sonin, V.; Ustimenko, A.; Kuibin, P.; Litvinov, I.; Shtork, S.
2016-11-01
One of the mechanisms of generation of powerful pressure pulsations in the circuit of the turbine is a precessing vortex core, formed behind the runner at the operation points with partial or forced loads, when the flow has significant residual swirl. To study periodic pressure pulsations behind the runner the authors of this paper use approaches of experimental modeling and methods of computational fluid dynamics. The influence of velocity distributions at the output of the hydro turbine runner on pressure pulsations was studied based on analysis of the existing and possible velocity distributions in hydraulic turbines and selection of the distribution in the extended range. Preliminary numerical calculations have showed that the velocity distribution can be modeled without reproduction of the entire geometry of the circuit, using a combination of two blade cascades of the rotor and stator. Experimental verification of numerical results was carried out in an air bench, using the method of 3D-printing for fabrication of the blade cascades and the geometry of the draft tube of hydraulic turbine. Measurements of the velocity field at the input to a draft tube cone and registration of pressure pulsations due to precessing vortex core have allowed building correlations between the velocity distribution character and the amplitude-frequency characteristics of the pulsations.
Unsteady numerical simulation of the flow in the U9 Kaplan turbine model
NASA Astrophysics Data System (ADS)
Javadi, Ardalan; Nilsson, Håkan
2014-03-01
The Reynolds-averaged Navier-Stokes equations with the RNG k-ε turbulence model closure are utilized to simulate the unsteady turbulent flow throughout the whole flow passage of the U9 Kaplan turbine model. The U9 Kaplan turbine model comprises 20 stationary guide vanes and 6 rotating blades (696.3 RPM), working at best efficiency load (0.71 m3/s). The computations are conducted using a general finite volume method, using the OpenFOAM CFD code. A dynamic mesh is used together with a sliding GGI interface to include the effect of the rotating runner. The clearance is included in the guide vane. The hub and tip clearances are also included in the runner. An analysis is conducted of the unsteady behavior of the flow field, the pressure fluctuation in the draft tube, and the coherent structures of the flow. The tangential and axial velocity distributions at three sections in the draft tube are compared against LDV measurements. The numerical result is in reasonable agreement with the experimental data, and the important flow physics close to the hub in the draft tube is captured. The hub and tip vortices and an on-axis forced vortex are captured. The numerical results show that the frequency of the forced vortex in 1/5 of the runner rotation.
NASA Technical Reports Server (NTRS)
Trinh, Huu P.; Early, Jim; Osborne, Robin; Thomas, Matthew; Bossard, John
2003-01-01
To pursue technology developments for future launch vehicles, NASA/Marshall Space Flight Center (MSFC) is examining vortex chamber concepts for liquid rocket engine applications. Past studies indicated that the vortex chamber schemes potentially have a number of advantages over conventional chamber methods. Due to the nature of the vortex flow, relatively cooler propellant streams tend to flow along the chamber wall. Hence, the thruster chamber can be operated without the need of any cooling techniques. This vortex flow also creates strong turbulence, which promotes the propellant mixing process. Consequently, the subject chamber concept: not only offer system simplicity, but also enhance the combustion performance. Test results have shown that chamber performance is markedly high even at a low chamber length-to-diameter ratio. This incentive can be translated to a convenience in the thrust chamber packaging.
Modeling of vortex generated sound in solid propellant rocket motors
NASA Technical Reports Server (NTRS)
Flandro, G. A.
1980-01-01
There is considerable evidence based on both full scale firings and cold flow simulations that hydrodynamically unstable shear flows in solid propellant rocket motors can lead to acoustic pressure fluctuations of significant amplitude. Although a comprehensive theoretical understanding of this problem does not yet exist, procedures were explored for generating useful analytical models describing the vortex shedding phenomenon and the mechanisms of coupling to the acoustic field in a rocket combustion chamber. Since combustion stability prediction procedures cannot be successful without incorporation of all acoustic gains and losses, it is clear that a vortex driving model comparable in quality to the analytical models currently employed to represent linear combustion instability must be formulated.
Vortex with fourfold defect lines in a simple model of self-propelled particles
NASA Astrophysics Data System (ADS)
Seyed-Allaei, Hamid; Ejtehadi, Mohammad Reza
2016-03-01
We study the formation of a vortex with fourfold symmetry in a minimal model of self-propelled particles, confined inside a squared box, using computer simulations and also theoretical analysis. In addition to the vortex pattern, we observe five other regimes in the system: a homogeneous gaseous phase, band structures, moving clumps, moving clusters, and vibrating rings. All six regimes emerge from controlling the strength of noise and from the contribution of repulsion and alignment interactions. We study the shape of the vortex and its symmetry in detail. The pattern shows exponential defect lines where incoming and outgoing flows of particles collide. We show that alignment and repulsion interactions between particles are necessary to form such patterns. We derive hydrodynamical equations with an introduction of the "small deviation" technique to describe the vortex phase. The method is applicable to other systems as well. Finally, we compare the theory with the results of both computer simulations and an experiment using Quincke rotors. A good agreement between the three is observed.
On random pressure pulses in the turbine draft tube
NASA Astrophysics Data System (ADS)
Kuibin, P. A.; Shtork, S. I.; Skripkin, S. G.; Tsoy, M. A.
2017-04-01
The flow in the conical part of the hydroturbine draft tube undergoes various instabilities due to deceleration and flow swirling at off-design operation points. In particular, the precessing vortex rope develops at part-load regimes in the draft tube. This rope induces periodical low-frequency pressure oscillations in the draft tube. Interaction of rotational (asynchronous) mode of disturbances with the elbow can bring to strong oscillations in the whole hydrodynamical system. Recent researches on flow structure in the discharge cone in a regime of free runner had revealed that helical-like vortex rope can be unstable itself. Some coils of helix close to each other and reconnection appears with generation of a vortex ring. The vortex ring moves toward the draft tube wall and downstream. The present research is focused on interaction of vortex ring with wall and generation of pressure pulses.
Ground Wind Vortex Sensing System Calibration Tests
DOT National Transportation Integrated Search
1980-02-01
This report describes the collection of data related to the calibration of two systems for detecting and tracking aircraft wake vortices. The systems tested were the propeller anemometer Ground Wind Vortex Sensing System and the Pulsed Acoustic Vorte...
Numerical Investigation of Cavitation Improvement for a Francis Turbine
NASA Astrophysics Data System (ADS)
Yao, Zhifeng; Xiao, Ruofu; Wang, Fujun; Yang, Wei
2015-12-01
Cavitation in hydraulic machine is undesired due to its negative effects on performances. To improve cavitation performance of a Francis turbine without the change of the best efficiency point, a model runner geometry optimization was carried out. Firstly, the runner outlet diameter was appropriately increased to reduce the flow velocity at runner outlet region. Then, to avoid the change of the flow rate at the best efficiency point, the blade shapes were carefully adjusted by decreasing the blade outlet angles and increasing the blade wrap angles. A large number of the modified runners were tested by computational fluid dynamic (CFD) method. Finally the most appropriate one was selected, which has the runner outlet diameter 10% larger, the blade outlet angles 3 degrees smaller and the blade wrap angles 5 degrees larger. The results showed that the critical cavitation coefficient of the model runner decreased at every unit rotational speed after the optimization, and the effect was much remarkable at relative high flow rate. Besides, by analysing the internal flow field, it was found that the zone of the low pressure on pressure surface of the optimized turbine blades was reduced, the backflow and vortex rope in draft tube were reduced, and the cavitation zone was reduced obviously.
2005-08-31
conditions; with X-ray radiography for erosion rate measurements. A vortex combustor was also designed to simulate propellant product species and to...DATES COVERED Interim Progress Report, August 1, 2004 to July 31, 2005 4. TITLE AND SUBTITLE Fundamental Understanding of Propellant /Nozzle...nozzle erosion by solid- propellant combustion products. Several processes can affect the nozzle erosion rate at high pressure and temperature
Advancements in Theoretical Models of Confined Vortex Flowfields
2007-03-29
blades, curved vanes, vortex generators, twisted tape inserts, triangular winglets , propellers, coiled wires, tangential injectors, and other...Corresponding boundary conditions consist of the no slip at the wall and blending with the composite inner solution in the outer domain. Following similar
Vortex sheet modeling with higher order curved panels. Ph.D Thesis Final Technical Report
NASA Technical Reports Server (NTRS)
Nagati, M. G.
1985-01-01
A numerical technique is presented for modeling the vortex sheet with a deformable surface definition, along which a continuous vortex strength distribution in the spanwise direction is applied, so that by repeatedly modifying its shape, its true configuration is approached, in the proximity of its generating wing. Design problems requiring the inclusion of a realistic configuration of the vortex sheet are numerous. Examples discussed include: control effectiveness and stability derivatives, longitudinal stability, lateral stability, canards, propellers and helicopter rotors, and trailing vortex hazards.
Propeller tip and hub vortex dynamics in the interaction with a rudder
NASA Astrophysics Data System (ADS)
Felli, Mario; Falchi, Massimo
2011-11-01
In the present paper, the interaction mechanisms of the vortices shed by a single-screw propeller with a rudder installed in its wake are addressed; in particular, following the works by Felli et al. (Exp Fluids 6(1):1-11, 2006a, Exp Fluids 46(1):147-1641, 2009a, Proceedings of the 8th international symposium on particle image velocimetry: Piv09, Melbourne, 2009b), the attention is focused on the analysis of the evolution, instability, breakdown and recovering mechanisms of the propeller tip and hub vortices during the interaction with the rudder. To investigate these mechanisms in detail, a wide experimental activity consisting in time-resolved visualizations, velocity measurements by particle image velocimetry (PIV) and laser Doppler velocimetry (LDV) along horizontal chordwise, vertical chordwise and transversal sections of the wake have been performed in the Cavitation Tunnel of the Italian Navy. Collected data allows to investigate the major flow features that distinguish the flow field around a rudder operating in the wake of a propeller, as, for example, the spiral breakdown of the vortex filaments, the rejoining mechanism of the tip vortices behind the rudder and the mechanisms governing the different spanwise misalignment of the vortex filaments in the pressure and suction sides of the appendage.
Similar Running Economy With Different Running Patterns Along the Aerial-Terrestrial Continuum.
Lussiana, Thibault; Gindre, Cyrille; Hébert-Losier, Kim; Sagawa, Yoshimasa; Gimenez, Philippe; Mourot, Laurent
2017-04-01
No unique or ideal running pattern is the most economical for all runners. Classifying the global running patterns of individuals into 2 categories (aerial and terrestrial) using the Volodalen method could permit a better understanding of the relationship between running economy (RE) and biomechanics. The main purpose was to compare the RE of aerial and terrestrial runners. Two coaches classified 58 runners into aerial (n = 29) or terrestrial (n = 29) running patterns on the basis of visual observations. RE, muscle activity, kinematics, and spatiotemporal parameters of both groups were measured during a 5-min run at 12 km/h on a treadmill. Maximal oxygen uptake (V̇O 2 max) and peak treadmill speed (PTS) were assessed during an incremental running test. No differences were observed between aerial and terrestrial patterns for RE, V̇O 2 max, and PTS. However, at 12 km/h, aerial runners exhibited earlier gastrocnemius lateralis activation in preparation for contact, less dorsiflexion at ground contact, higher coactivation indexes, and greater leg stiffness during stance phase than terrestrial runners. Terrestrial runners had more pronounced semitendinosus activation at the start and end of the running cycle, shorter flight time, greater leg compression, and a more rear-foot strike. Different running patterns were associated with similar RE. Aerial runners appear to rely more on elastic energy utilization with a rapid eccentric-concentric coupling time, whereas terrestrial runners appear to propel the body more forward rather than upward to limit work against gravity. Excluding runners with a mixed running pattern from analyses did not affect study interpretation.
Aircraft propeller induced structure-borne noise
NASA Technical Reports Server (NTRS)
Unruh, James F.
1989-01-01
A laboratory-based test apparatus employing components typical of aircraft construction was developed that would allow the study of structure-borne noise transmission due to propeller induced wake/vortex excitation of in-wake structural appendages. The test apparatus was employed to evaluate several aircraft installation effects (power plant placement, engine/nacelle mass loading, and wing/fuselage attachment methods) and several structural response modifications for structure-borne noise control (the use of wing blocking mass/fuel, wing damping treaments, and tuned mechanical dampers). Most important was the development of in-flight structure-borne noise transmission detection techniques using a combination of ground-based frequency response function testing and in-flight structural response measurement. Propeller wake/vortex excitation simulation techniques for improved ground-based testing were also developed to support the in-flight structure-borne noise transmission detection development.
Some design philosophy for reducing the community noise of advanced counter-rotation propellers
NASA Technical Reports Server (NTRS)
Dittmar, J. H.
1985-01-01
Advanced counter-rotation propellers have been indicated as possibly generating an unacceptable amount of noise for the people living near an airport. This report has explored ways to reduce this noise level, which is treated as being caused by the interaction of the upstream propeller wakes and vortices with the downstream propeller. The noise reduction techniques fall into two categories: (1) reducing the strength of the wakes and vortices, and (2) reducing the response of the downstream blades to them. The noise from the wake interaction was indicated as being reduced by increased propeller spacing and decreased blade drag coefficient. The vortex-interaction noise could be eliminated by having the vortex pass over the tips of the downstream blade, and it could be reduced by increased spacing or decreased initial circulation. The downstream blade response could be lessened by increasing the reduced frequency parameter omega or by phasing of the response from different sections to have a mutual cancellation effect. Uneven blade to blade spacing for the downstream blading was indicated as having a possible effect on the annoyance of counter-rotation propeller noise. Although there are undoubtedly additional methods of noise reduction not covered in this report, the inclusion of the design methods discussed would potentially result in a counter-rotation propeller that is acceptably quiet.
NASA Technical Reports Server (NTRS)
Jumper, S. J.
1982-01-01
A computer program was developed to calculate the three dimensional, steady, incompressible, inviscid, irrotational flow field at the propeller plane (propeller removed) located upstream of an arbitrary airframe geometry. The program uses a horseshoe vortex of known strength to model the wing. All other airframe surfaces are modeled by a network source panels of unknown strength which is exposed to a uniform free stream and the wing-induced velocity field. By satisfying boundary conditions on each panel (the Neumann problem), relaxed boundary conditions being used on certain panels to simulate inlet inflow, the source strengths are determined. From the known source and wing vortex strengths, the resulting velocity fields on the airframe surface and at the propeller plane are obtained. All program equations are derived in detail, and a brief description of the program structure is presented. A user's manual which fully documents the program is cited. Computer predictions of the flow on the surface of a sphere and at a propeller plane upstream of the sphere are compared with the exact mathematical solutions. Agreement is good, and correct program operation is verified.
Vortex conception of rotor and mutual effect of screw/propellers
NASA Technical Reports Server (NTRS)
Lepilkin, A. M.
1986-01-01
A vortex theory of screw/propellers with variable circulation according to the blade and its azimuth is proposed, the problem is formulated and circulation is expanded in a Fourier series. Equations are given for inductive velocities in space for crews, including those with an infinitely large number of blades and expansion of the inductive velocity by blade azimuth of a second screw. Multiparameter improper integrals are given as a combination of elliptical integrals and elementary functions, and it is shown how to reduce elliptical integrals of the third kind with a complex parameter to integrals with a real parameter.
Experimental Investigation of Inter-Blade Vortices in a Model Francis Turbine
NASA Astrophysics Data System (ADS)
LIU, Demin; LIU, Xiaobing; ZHAO, Yongzhi
2017-07-01
The inter-blade vortex in a Francis turbine becomes one of the main hydraulic factors that are likely to cause blade erosion at deep part load operating conditions. However, the causes and the mechanism of inter-blade vortex are still under investigation according to present researches. Thus the causes of inter-blade vortex and the effect of different hydraulic parameters on the inter-blade vortex are investigated experimentally. The whole life cycle of the inter-blade vortex is observed by a high speed camera. The test results illustrate the whole life cycle of the inter-blade vortex from generation to separation and even to fading. It is observed that the inter-blade vortex becomes stronger with the decreasing of flow and head, which leads to pressure fluctuation. Meanwhile, the pressure fluctuations in the vane-less area and the draft tube section become stronger when inter-blade vortices exist in the blade channel. The turbine will be damaged if operating in the inter-blade vortex zone, so its operating range must be far away from that zone. This paper reveals the main cause of the inter-blade vortex which is the larger incidence angle between the inflow angle and the blade angle on the leading edge of the runner at deep part load operating conditions.
Study on Prediction of Underwater Radiated Noise from Propeller Tip Vortex Cavitation
NASA Astrophysics Data System (ADS)
Yamada, Takuyoshi; Sato, Kei; Kawakita, Chiharu; Oshima, Akira
2015-12-01
The method to predict underwater radiated noise from tip vortex cavitation was studied. The growth of a single cavitation bubble in tip vortex was estimated by substituting the tip vortex to Rankine combined vortex. The ideal spectrum function for the sound pressure generated by a single cavitation bubble was used, also the empirical factor for the number of collapsed bubbles per unit time was introduced. The estimated noise data were compared with measured ship's ones and it was found out that this method can estimate noise data within 3dB difference.
DOT National Transportation Integrated Search
1978-12-01
A Boeing 747 aircraft flew 54 passes at low altitude over ground based sensors. Vortex velocities were measured by a laser Doppler velocimeter, an array of monostatic acoustic sounders, and an array of propeller anemometers. Flow visualization of the...
A comparison of the structureborne and airborne paths for propfan interior noise
NASA Technical Reports Server (NTRS)
Eversman, W.; Koval, L. R.; Ramakrishnan, J. V.
1986-01-01
A comparison is made between the relative levels of aircraft interior noise related to structureborne and airborne paths for the same propeller source. A simple, but physically meaningful, model of the structure treats the fuselage interior as a rectangular cavity with five rigid walls. The sixth wall, the fuselage sidewall, is a stiffened panel. The wing is modeled as a simple beam carried into the fuselage by a large discrete stiffener representing the carry-through structure. The fuselage interior is represented by analytically-derived acoustic cavity modes and the entire structure is represented by structural modes derived from a finite element model. The noise source for structureborne noise is the unsteady lift generation on the wing due to the rotating trailing vortex system of the propeller. The airborne noise source is the acoustic field created by a propeller model consistent with the vortex representation. Comparisons are made on the basis of interior noise over a range of propeller rotational frequencies at a fixed thrust.
A novel scenario of aperiodical impacts appearance in the turbine draft tube
NASA Astrophysics Data System (ADS)
Alekseenko, S. V.; Kuibin, P. A.; Shtork, S. I.; Skripkin, S. G.; Sonin, V. I.; Tsoy, M. A.; Ustimenko, A. S.
2016-11-01
The swirling flow in the discharge cone of hydroturbine is characterized by various self-induced instabilities and associated low frequency phenomena when the turbine is operated far from the best efficiency point. In particular, the precessing vortex rope develops at part-load regimes in the draft tube. This rope can serve a reason of the periodical low- frequency pressure oscillations in the whole hydrodynamical system. During the experimental research of flow structure in the discharge cone in a regime of free runner new interesting phenomenon was discovered. Due to instability some coils of helical vortex close to each other and reconnection appears with generation of a vortex ring. The experiments were fulfilled at the cavitational conditions when a cavity arises in the vortex core. So the phenomenon was registered with help of visualization by the high speed video recording. The vortex ring after the reconnection moves apart from the main vortex rope toward the wall and downstream. When it reaches the area with high pressure the cavity collapses with generation of pressure impact. The mechanism of cavitational vortex rings generation and their further collapse can serve as a prototype of the aperiodical pressure impacts inside the turbine draft tube.
Analysis of Ground-Wind Vortex Sensing System Data from O'Hare International Airport
DOT National Transportation Integrated Search
1980-09-01
From July 1976 through September 1977, aircraft wake vortex data were collected on the approach to runways 14R, 27R, and 32L at O'Hare International Airport. The vortices from over 21,000 aircraft were tracked using the propeller anemometer Ground-Wi...
Noise of two high-speed model counter-rotation propellers at takeoff/approach conditions
NASA Astrophysics Data System (ADS)
Woodward, Richard P.
1992-08-01
This paper presents acoustic results for two model counter-rotation propellers which were tested in the NASA Lewis 9- x 15-ft Anechoic Wind Tunnel. The propellers had a common forward rotor, but the diameter of the aft rotor of the second propeller was reduced in an effort to reduce its interaction with the forward rotor tip vortex. The propellers were tested at Mach 0.20, which is representative of takeoff/approach operation. Acoustic results are presented for these propellers which show the effect of rotor spacing, reduced aft rotor diameter, operation at angle-of-attack, blade loading, and blade number. Limited aerodynamic results are also presented to establish the propeller operating conditions.
Noise of two high-speed model counter-rotation propellers at takeoff/approach conditions
NASA Technical Reports Server (NTRS)
Woodward, Richard P.
1992-01-01
This paper presents acoustic results for two model counter-rotation propellers which were tested in the NASA Lewis 9- x 15-ft Anechoic Wind Tunnel. The propellers had a common forward rotor, but the diameter of the aft rotor of the second propeller was reduced in an effort to reduce its interaction with the forward rotor tip vortex. The propellers were tested at Mach 0.20, which is representative of takeoff/approach operation. Acoustic results are presented for these propellers which show the effect of rotor spacing, reduced aft rotor diameter, operation at angle-of-attack, blade loading, and blade number. Limited aerodynamic results are also presented to establish the propeller operating conditions.
Variable-gravity anti-vortex and vapor-ingestion-suppression device
NASA Technical Reports Server (NTRS)
Grayson, Gary D. (Inventor)
2003-01-01
A liquid propellant management device for placement in a liquid storage tank adjacent an outlet of the storage tank to substantially reduce or eliminate the formation of a dip and vortex in the liquid of the tank, as well as prevent vapor ingestion into the outlet, as the liquid drains out through the outlet. The liquid propellant management device has a first member adapted to suppress the formation of a vortex of a liquid exiting the storage tank. A plate is affixed generally perpendicular to the first member, wherein the plate is adapted to suppress vapor ingestion into the outlet by reducing a dip in a surface level of the liquid leaving the tank. A second member is affixed to the second side of the plate. The second member ensures that the plate is wet with liquid and assists in positioning bubbles away from the outlet.
Compressive spherical beamforming for localization of incipient tip vortex cavitation.
Choo, Youngmin; Seong, Woojae
2016-12-01
Noises by incipient propeller tip vortex cavitation (TVC) are generally generated at regions near the propeller tip. Localization of these sparse noises is performed using compressive sensing (CS) with measurement data from cavitation tunnel experiments. Since initial TVC sound radiates in all directions as a monopole source, a sensing matrix for CS is formulated by adopting spherical beamforming. CS localization is examined with known source acoustic measurements, where the CS estimated source position coincides with the known source position. Afterwards, CS is applied to initial cavitation noise cases. The result of cavitation localization was detected near the upper downstream area of the propeller and showed less ambiguity compared to Bartlett spherical beamforming. Standard constraint in CS was modified by exploiting the physical features of cavitation to suppress remaining ambiguity. CS localization of TVC using the modified constraint is shown according to cavitation numbers and compared to high-speed camera images.
1985-07-01
vortex filaments instead of the continuous sheet of vorticity used by Goldstein the propeller-nacelle interaction analysis also represents the wake by...the US Manufacturers in parallel with the development of the experimental propeller models , illustrated on Figre 0, these analysis methods range from...still poor, the difference between the two methods being mainly due to .,ifferent approaches used for obtaining lift. The Euler analysis of swirl angle
Installation effects on propeller wake/vortex induced structure-borne noise transmission
NASA Technical Reports Server (NTRS)
Unruh, J. F.
1989-01-01
A laboratory-based test apparatus was employed to investigate the effects of power-plant placement, engine/nacelle mass installation, and wing-to-fuselage attachment methods on propeller-induced structure-borne noise (SBN) transmission levels and their effects on noise-control measures. Data are presented showing SBN transmission is insensitive to propeller spanwise placement, however some sensitivity is seen in propeller-to-wing spacing. Installation of an engine/nacelle mass and variation in wing-to-fuselage attachments have measurable influences on SBN transmission and control measures.
Cavitation noise studies on marine propellers
NASA Astrophysics Data System (ADS)
Sharma, S. D.; Mani, K.; Arakeri, V. H.
1990-04-01
Experimental observations are described of cavitation inception and noise from five model propellers, three basic and two modified, tested in the open jet section of the Indian Institute of Science high-speed water tunnel facility. Extensive experiments on the three basic propellers of different design, which included visualization of cavitation and measurements of noise, showed that the dominant type of cavitation was in the form of tip vortex cavitation, accompanied by leading edge suction side sheet cavitation in its close vicinity, and the resultant noise depended on parameters such as the advance coefficient, the cavitation number, and the propeller geometry. Of these, advance coefficient was found to have the maximum influence not only on cavitation noise but also on the inception of cavitation. Noise levels and frequencies of spectra obtained from all the three basic propellers at conditions near inception and different advance coefficient values, when plotted in the normalized form as suggested by Blake, resulted in a universal spectrum which would be useful for predicting cavitation noise at prototype scales when a limited extent of cavitation is expected in the same form as observed on the present models. In an attempt to delay the onset of tip vortex cavitation, the blades of two of the three basic propellers were modified by drilling small holes in the tip and leading edge areas. Studies on the modified propellers showed that the effectiveness of the blade modification was apparently stronger at low advance coefficient values and depended on the blade sectional profile. Measurements of cavitation noise indicated that the modification also improved the acoustic performance of the propellers as it resulted in a complete attenuation of the low-frequency spectral peaks, which were prominent with the basic propellers. In addition to the above studies, which were conducted under uniform flow conditions, one of the basic propellers was tested in the simulated wake of a typical single screw ship. The wake was simulated by using a wire screen technique. Observations of cavitation and measurement of noise clearly showed that the presence of the wake had a strong influence on the propeller cavitation and noise performance. Cavitation was found to be of the cloud type, which generated very intense noise compared to that generated by tip vortex cavitation along with leading edge suction side sheet cavitation in the uniform flow conditions. The noise spectra obtained with wake simulation also are presented in a normalized form to be of general utility.
Pressure pulsations and hydraulic efficiency at Smeland power plant
NASA Astrophysics Data System (ADS)
Ulvan, V. S.; Kverno, J. O.; Dahlhaug, O. G.
2018-06-01
Smeland power plant in Norway is experiencing pressure pulsations in their Francis turbine when running above best efficiency point. By measuring both the pressure pulsations and runner efficiency, the cause and effect of the pulsations are to be investigated thoroughly, which is this works main purpose. To find the Francis runners efficiency the thermodynamic method has been used, which builds on the principle that all of the hydraulic losses turns into heat in the flow itself. By measuring the change of temperature before and after the turbine one can, with little other data, calculate the hydraulic efficiency. To identify the pressure pulsations, pressure transducers were placed on the inlet to the spiral casing, draft tube, and upper labyrinth. While doing measurements, air-injection through the runner was tested on full load, which nearly eradicated the pressure pulsations. This might be due to an increase of volume in a pulsating full load vortex that changed its eigenfrequency, and therefore stopped resonating.
Tai, Suh-Jun; Liu, Ren-Shyan; Kuo, Ya-Chen; Hsu, Chi-Yang; Chen, Chi-Hsien
2010-04-30
The aim of this study was to determine glucose uptake patterns in exercised skeletal muscles of elite male long-distance and short-distance runners. Positron emission tomography (PET) using 18F-fluoro-2-deoxyglucose (FDG) was performed to determine the patterns of glucose uptake in lower limbs of short-distance (SD group, n=8) and long-distance (LD group, n=8) male runners after a modified 20 min Bruce treadmill test. Magnetic resonance imaging (MRI) was used to delineate the muscle groups in lower limbs. Muscle groups from hip, knee, and ankle movers were measured. The total FDG uptake and the standard uptake value (SUV) for each muscle group were compared between the 2 groups. For the SD and LD runners, the 2 major muscle groups utilizing glucose during running were knee extensors and ankle plantarflexors, which accounted for 49.3 +/- 8.1% (25.1 +/- 4.7% and 24.2 +/- 6.0%) of overall lower extremity glucose uptake for SD group, and 51.3 +/- 8.0% (27.2 +/- 2.7% and 24.0 +/- 8.1%) for LD group. No difference in muscle glucose uptake was noted for other muscle groups. For SD runners, the SUVs for the muscle groups varied from 0.49 +/- 0.27 for the ankle plantarflexors, to 0.20 +/- 0.08 for the hip flexor. For the LD runners, the highest and lowest SUVs were 0.43 +/- 0.15 for the ankle dorsiflexors and 0.21 +/- 0.19 for the hip. For SD and LD groups, no difference in muscle SUV was noted for the muscle groups. However, the SUV ratio between the ankle dorsiflexors and plantarflexors in the LD group was significantly greater than that in the SD group. We thus conclude that the major propelling muscle groups account for approximately 50% of lower limb glucose utilization during running. Thus, the other muscle groups involving maintenance of balance, limb deceleration, and shock absorption utilize an equal amount. This result provides a new insight into glucose distribution in skeletal muscle, suggesting that propellers and supporters are both energetically important during running. Furthermore, for each unit muscle volume, movers of ankle are more glucose-demanding than those of hip.
Influence of Initial Vorticity Distribution on Axisymmetric Vortex Breakdown and Reconnection
NASA Technical Reports Server (NTRS)
Young, Larry A.
2007-01-01
An analytical treatment has been developed to study some of the axisymmetric vortex breakdown and reconnection fluid dynamic processes underlying body-vortex interactions that are frequently manifested in rotorcraft and propeller-driven fixed-wing aircraft wakes. In particular, the presence of negative vorticity in the inner core of a vortex filament (one example of which is examined in this paper) subsequent to "cutting" by a solid body has a profound influence on the vortex reconnection, leading to analog flow behavior similar to vortex breakdown phenomena described in the literature. Initial vorticity distributions (three specific examples which are examined) without an inner core of negative vorticity do not exhibit vortex breakdown and instead manifest diffusion-like properties while undergoing vortex reconnection. Though this work focuses on laminar vortical flow, this work is anticipated to provide valuable insight into rotary-wing aerodynamics as well as other types of vortical flow phenomena.
Prediction of aerodynamic noise in a ring fan based on wake characteristics
NASA Astrophysics Data System (ADS)
Sasaki, Soichi; Fukuda, Masaharu; Tsujino, Masao; Tsubota, Haruhiro
2011-06-01
A ring fan is a propeller fan that applies an axial-flow impeller with a ring-shaped shroud on the blade tip side. In this study, the entire flow field of the ring fan is simulated using computational fluid dynamics (CFD); the accuracy of the CFD is verified through a comparison with the aerodynamic characteristics of a propeller fan of current model. Moreover, the aerodynamic noise generated by the fan is predicted on the basis of the wake characteristics. The aerodynamic characteristic of the ring fan based on CFD can represent qualitatively the variation in the measured value. The main flow domain of the ring fan is formed at the tip side of the blade because blade tip vortex is not formed at that location. Therefore, the relative velocity of the ring fan is increased by the circumferential velocity. The sound pressure levels of the ring fan within the frequency band of less than 200 Hz are larger than that of the propeller fan. In the analysis of the wake characteristics, it revealed that Karman vortex shedding occurred in the main flow domain in the frequency domain lower than 200 Hz; the aerodynamic noise of the ring fan in the vortex shedding frequency enlarges due to increase in the relative velocity and the velocity fluctuation.
A Surface Panel Method for the Hydrodynamic Analysis of Ducted Propellers
1987-01-01
Flow About Arbitrary Three-Dimensional Lifting Bodies," Technical Report MDC J5679-01, McDonnell Douglas Corp., Oct. 197. 32 Van Manen , J. D...to that developed by Van Houten (4] for use with his vortex of a control point is less than the radius of the true surface. lattice ducted propeller...Boswell, R. J. and Miller, M. L., "Unsteady Propeller Load- erlands, 1983. ing-Measurement, Correlation, with Theory and Parametric 4 Van Houten, R
NASA Astrophysics Data System (ADS)
Liu, Hanlin; Troolin, Daniel; Hortensius, Ruben; Pothos, Stamatios; Curet, Oscar
2017-11-01
An undulating fin represents a remarkable propulsion model for underwater vehicles due to its high propulsive efficiency and considerable locomotor capabilities. In this work, we used a bio-inspired vessel, the KnifeBot to demonstrate the maneuverability of undulating fin propulsion, including forward-backward swimming, station keeping and vertical swimming. This self-contained robotic system uses an undulating ventral fin as the propulsor and features a slender 3D-printed hull with 16 motors, 2 batteries and electronic boards encapsulated inside. We tested the robot in a water-filled tank and used volumetric particle image velocimetry (V3V PIV) to investigate the three-dimensional flow features and vortex structures generated by the undulating ribbon fin in free-swimming maneuvers. Our results indicate that in the forward swimming, a series of vortex tubes are shed off the fin edge. A streamwise jet at an oblique angle to the fin is generated in association with the vortex tubes propelling the robot forward as well as pitching it up. For the hovering maneuver with inward counter-propagating waves. The streamlines develop vertically downward with the tip vortex shed from the fin edge. This downward jet provides substantial heave force for the robot to swim upward or perform station keeping. Our findings will be useful for understanding the mechanical basis of undulating fin propulsion and facilitate the development of bio-inspired vehicles using undulatory propellers. Office of Naval Research under Award Number N00014-16-1-2505.
Localization of incipient tip vortex cavitation using ray based matched field inversion method
NASA Astrophysics Data System (ADS)
Kim, Dongho; Seong, Woojae; Choo, Youngmin; Lee, Jeunghoon
2015-10-01
Cavitation of marine propeller is one of the main contributing factors of broadband radiated ship noise. In this research, an algorithm for the source localization of incipient vortex cavitation is suggested. Incipient cavitation is modeled as monopole type source and matched-field inversion method is applied to find the source position by comparing the spatial correlation between measured and replicated pressure fields at the receiver array. The accuracy of source localization is improved by broadband matched-field inversion technique that enhances correlation by incoherently averaging correlations of individual frequencies. Suggested localization algorithm is verified through known virtual source and model test conducted in Samsung ship model basin cavitation tunnel. It is found that suggested localization algorithm enables efficient localization of incipient tip vortex cavitation using a few pressure data measured on the outer hull above the propeller and practically applicable to the typically performed model scale experiment in a cavitation tunnel at the early design stage.
NASA Astrophysics Data System (ADS)
Favrel, A.; Müller, A.; Landry, C.; Gomes, J.; Yamamoto, K.; Avellan, F.
2017-04-01
At part load conditions, Francis turbines experience the formation of a cavitation vortex rope at the runner outlet whose precession acts as a pressure excitation source for the hydraulic circuit. This can lead to hydro-acoustic resonances characterized by high pressure pulsations, as well as torque and output power fluctuations. This study highlights the influence of the discharge factor on both the vortex parameters and the pressure excitation source by performing Particle Image Velocimetry (PIV) and pressure measurements. Moreover, it is shown that the occurrence of hydro-acoustic resonances in cavitation conditions mainly depend on the swirl degree of the flow independently of the speed factor. Empirical laws linking both natural and precession frequencies with the operating parameters of the machine are, then, derived, enabling the prediction of resonance conditions on the complete part load operating range of the turbine.
Aperiodic pressure pulsation under non optimal hydraulic turbine regimes at low swirl number
NASA Astrophysics Data System (ADS)
Skripkin, S. G.; Tsoy, M. A.; Kuibin, P. A.; Shtork, S. I.
2017-09-01
Off-design operating conditions of hydraulic turbines is hindered by pressure fluctuations in the draft tube of the turbine. A precessing helical vortex rope develops, which imperils the mechanical structure and limits the operation flexibility of hydropower station. Understanding of the underlying instabilities of precessing vortex rope at low swirl number is incomplete. In this paper flow regimes with different residual swirl is analysed, particular attention is paid to the regime with a small swirl parameter. Study defines upper and low boundaries of regime where aperiodic pressure surge is observed. Flow field at the runner exit is investigated by Laser Doppler Velocimetry and high-speed visualizations, which are complemented draft tube wall pressure measurements.
Kick-Sledding: An Outdoor Activity for Everyone.
ERIC Educational Resources Information Center
Wilson, Susan
1994-01-01
Kick-sledding is an outdoor activity that originated in Scandinavia. Kick-sleds may be used on snowy roads, cross-country ski trails, and frozen lakes by anyone, including seniors, children, and mothers with babies. To ride a kick-sled, you stand holding onto a bar across the back of a chair attached to runners and propel yourself by kicking. (LP)
The 17th JANNAF Combustion Meeting, Volume 1
NASA Technical Reports Server (NTRS)
Eggleston, D. S. (Editor)
1980-01-01
The combustion of solid rocket propellants and combustion in ramjets is addressed. Subjects discussed include metal burning, steady-state combustion of composite propellants, velocity coupling and nonlinear instability, vortex shedding and flow effects on combustion instability, combustion instability in solid rocket motors, combustion diagnostics, subsonic and supersonic ramjet combustion, characterization of ramburner flowfields, and injection and combustion of ramjet fuels.
NASA Astrophysics Data System (ADS)
Thapa, B. S.; Dahlhaug, O. G.; Thapa, B.
2016-11-01
In Francis turbine, a small clearance gap between the guide vanes and the cover plates is usually required to pivot guide vanes as a part of governing system. Deflection of cover plates and erosion of mating surfaces causes this gap to increase from its design value. The clearance gap induces the secondary flow in the distributor system. This effects the main flow at the runner inlet, which causes losses in efficiency and instability. A guide vane cascade of a low specific speed Francis turbine has been developed for experimental investigations. The test setup is able to produce similar velocity distributions at the runner inlet as that of a reference prototype turbine. The setup is designed for particle image velocimetry (PIV) measurements from the position of stay vane outlet to the position of runner inlet. In this study, velocity and pressure measurements are conducted with 2 mm clearance gap on one side of guide vane. Leakage flow is observed and measured together with pressure measurements. It is concluded that the leakage flow behaves as a jet and mixes with the main flow in cross-wise direction and forms a vortex filament. This causes non-uniform inlet flow conditions at runner blades.
NASA Astrophysics Data System (ADS)
Favrel, A.; Müller, A.; Landry, C.; Yamamoto, K.; Avellan, F.
2016-11-01
The large-scale penetration of the electrical grid by intermittent renewable energy sources requires a continuous operating range extension of hydropower plants. This causes the formation of unfavourable flow patterns in the draft tube of turbines and pump-turbines. At partial load operation, a precessing cavitation vortex rope is formed at the Francis turbine runner outlet, acting as an excitation source for the hydraulic system. In case of resonance, the resulting high-amplitude pressure pulsations can put at risk the stability of the machine and of the electrical grid to which it is connected. It is therefore crucial to understand and accurately simulate the underlying physical mechanisms in such conditions. However, the exact impact of cavitation and hydro-acoustic resonance on the flow velocity fluctuations in the draft tube remains to be established. The flow discharge pulsations expected to occur in the draft tube in resonance conditions have for instance never been verified experimentally. In this study, two-component Laser Doppler Velocimetry is used to investigate the axial and tangential velocity fluctuations at the runner outlet of a reduced scale physical model of a Francis turbine. The investigation is performed for a discharge equal to 64 % of the nominal value and three different pressure levels in the draft tube, including resonance and cavitation-free conditions. Based on the convective pressure fluctuations induced by the vortex precession, the periodical velocity fluctuations over one typical precession period are recovered by phase averaging. The impact of cavitation and hydro-acoustic resonance on both axial and tangential velocity fluctuations in terms of amplitude and phase shift is highlighted for the first time. It is shown that the occurrence of resonance does not have significant effects on the draft tube velocity fields, suggesting that the synchronous axial velocity fluctuations are surprisingly negligible compared to the velocity fluctuations induced by the vortex precession.
NASA Technical Reports Server (NTRS)
Dittmar, James H.
1987-01-01
The effect of front-to-rear propeller spacing on the interaction noise of a counterrotation propeller model was measured at cruise conditions. The data taken at an axial Mach number of 0.80 behaved as expected: interaction noise was reduced with increased spacing. The data taken at M=0.76 and M=0.72 did not behave as expected. At some of the test conditions the noise was unchanged; others even showed noise increases with increased spacing. A possible explanation, involving the amount of downstream blade area impacted by the tip vortex, is presented.
Reference measurements on a Francis model turbine with 2D Laser-Doppler-Anemometry
NASA Astrophysics Data System (ADS)
Frey, A.; Kirschner, O.; Riedelbauch, S.; Jester-Zuerker, R.; Jung, A.
2016-11-01
To validate the investigations of a high-resolution CFD simulation of a Francis turbine, measurements with 2D Laser-Doppler-Anemometry are carried out. The turbine is operated in part load, where a rotating vortex rope occurs. To validate both, mean velocities and velocity fluctuations, the measurements are classified relative to the vortex rope position. Several acrylic glass windows are installed in the turbine walls such as upstream of the spiral case inlet, in the vaneless space and in the draft tube. The current investigation is focused on a measurement plane below the runner. 2D velocity components are measured on this whole plane by measuring several narrow spaced radial lines. To avoid optical refraction of the laser beam a plan parallel window is inserted in the cone wall. The laser probe is positioned with a 2D traverse system consisting of a circumferential rail and a radial aligned linear traverse. The velocity data are synchronized with the rotational frequency of the rotating vortex rope. The results of one measurement line show the dependency of the axial and circumferential velocities on the vortex rope position.
Simulation of air admission in a propeller hydroturbine during transient events
NASA Astrophysics Data System (ADS)
Nicolle, J.; Morissette, J.-F.
2016-11-01
In this study, multiphysic simulations are carried out in order to model fluid loading and structural stresses on propeller blades during startup and runaway. It is found that air admission plays an important role during these transient events and that biphasic simulations are therefore required. At the speed no load regime, a large air pocket with vertical free surface forms in the centre of the runner displacing the water flow near the shroud. This significantly affects the torque developed on the blades and thus structural loading. The resulting pressures are applied to a quasi-static structural model and good agreement is obtained with experimental strain gauge data.
Noise reduction for model counterrotation propeller at cruise by reducing aft-propeller diameter
NASA Technical Reports Server (NTRS)
Dittmar, James H.; Stang, David B.
1987-01-01
The forward propeller of a model counterrotation propeller was tested with its original aft propeller and with a reduced diameter aft propeller. Noise reductions with the reduced diameter aft propeller were measured at simulated cruise conditions. Reductions were as large as 7.5 dB for the aft-propeller passing tone and 15 dB in the harmonics at specific angles. The interaction tones, mostly the first, were reduced probably because the reduced-diameter aft-propeller blades no longer interacted with the forward propeller tip vortex. The total noise (sum of primary and interaction noise) at each harmonic was significantly reduced. The chief noise reduction at each harmonic came from reduced aft-propeller-alone noise, with the interaction tones contributing little to the totals at cruise. Total cruise noise reductions were as much as 3 dB at given angles for the blade passing tone and 10 dB for some of the harmonics. These reductions would measurably improve the fuselage interior noise levels and represent a definite cruise noise benefit from using a reduced diameter aft propeller.
NASA Astrophysics Data System (ADS)
Prothin, Sebastien; Djeridi, Henda; Billard, Jean-Yves
2014-05-01
In this paper, the influence of a single tip vortex on boundary layer detachment is studied. This study offers a preliminary approach in order to better understand the interaction between a propeller hub vortex and the rudder installed in its wake. This configuration belongs to the field of marine propulsion and encompasses such specific problem as cavitation inception, modification of propulsive performances and induced vibrations. To better understand the complex mechanisms due to propeller-rudder interactions it was decided to emphasize configurations where the hub vortex is generated by an elliptical 3-D foil and is located upstream of a 2-D NACA0015 foil at high incidences for a Reynolds number of 5×105. The physical mechanisms were studied using Time Resolved Stereoscopic Particle Image Velocimetry (TR-SPIV) techniques. Particular attention was paid to the detachment at 25° incidence and a detailed cartography of the mean and turbulent properties of the wake is presented. Proper Orthogonal Decomposition (POD) analysis was applied in order to highlight the unsteady nature of the flow using phase averaging based on the first POD coefficients to characterize the turbulent and coherent process in the near wake of the rudder.
Tip leakage vortex dynamics and inception
NASA Astrophysics Data System (ADS)
Oweis, Ghanem; Ceccio, Steven; Jessup, Stuart; Chesnakas, Christopher; Fry, David
2002-11-01
The McCormick rule for tip vortex cavitation scaling predicts that cavitation should take place in the vortex where the average core pressure deficit from the free stream is the largest along the vortex tube. The average core pressure deficit can be calculated from the vortex core size and circulation and these can be measured by LDV or hot wire, among other methods. The same rule applies to the tip vortex from a wall-bounded hydrofoil. Recent cavitation inception experiments on a ducted propeller in the NSWCCD 36 inch water tunnel combined with PIV and LDV measurements of the tip vortex flow are described. These tests reveal a disagreement between the actual inception location and that predicted by the McCormick rule. It is hypothesized that in this case the inception mechanism is related to local flow phenomena associated with local vortex unsteadiness, as opposed to the average vortex parameters (core size and circulation) used in the viscous scaling rule of McCormick. Discussion of the flow field measurements, bubble population, and the noise production from the inception events is given.
A Computational Fluid Dynamics Study of Swirling Flow Reduction by using Anti-vortex Baffle
NASA Technical Reports Server (NTRS)
Yang, H. Q.; Peugeot, John W.; West, Jeff S..
2013-01-01
An anti-vortex baffle is a liquid propellant management device placed adjacent to an outlet of the propellant tank. Its purpose is to substantially reduce or eliminate the formation of free surface dip and vortex, as well as prevent vapor ingestion into the outlet, as the liquid drains out through the flight. To design an effective anti-vortex baffle, Computational Fluid Dynamic (CFD) simulations were undertaken for the NASA Ares I vehicle LOX tank subjected to the simulated flight loads with and without the anti-vortex baffle. The Six Degree-Of-Freedom (6- DOF) dynamics experienced by the Crew Launch Vehicle (CLV) during ascent were modeled by modifying the momentum equations in a CFD code to accommodate the extra body forces from the maneuvering in a non-inertial frame. The present analysis found that due to large moments, the CLV maneuvering has significant impact on the vortical flow generation inside the tank. Roll maneuvering and side loading due to pitch and yaw are shown to induce swirling flow. The vortical flow due to roll is symmetrical with respect to the tank centerline, while those induced by pitch and yaw maneuverings showed two vortices side by side. The study found that without the anti-vortex baffle, the swirling flow caused surface dip during the late stage of drainage and hence early vapor ingestion. The flow can also be non-uniform in the drainage pipe as the secondary swirling flow velocity component can be as high as 10% of the draining velocity. An analysis of the vortex dynamics shows that the swirling flow in the drainage pipe during the Upper Stage burn is mainly the result of residual vortices inside the tank due to conservation of angular momentum. The study demonstrated that the swirling flow in the drainage pipe can be effectively suppressed by employing the anti-vortex baffle.
A Computational Fluid Dynamics Study of Swirling Flow Reduction by Using Anti-Vortex Baffle
NASA Technical Reports Server (NTRS)
Yang, H. Q.; Peugeot, John W.; West, Jeff S.
2017-01-01
An anti-vortex baffle is a liquid propellant management device placed adjacent to an outlet of the propellant tank. Its purpose is to substantially reduce or eliminate the formation of free surface dip and vortex, as well as prevent vapor ingestion into the outlet, as the liquid drains out through the flight. To design an effective anti-vortex baffle, Computational Fluid Dynamic (CFD) simulations were undertaken for the NASA Ares I vehicle LOX tank subjected to the simulated flight loads with and without the anti-vortex baffle. The Six Degree-Of-Freedom (6-DOF) dynamics experienced by the Crew Launch Vehicle (CLV) during ascent were modeled by modifying the momentum equations in a CFD code to accommodate the extra body forces from the maneuvering in a non-inertial frame. The present analysis found that due to large moments, the CLV maneuvering has a significant impact on the vortical flow generation inside the tank. Roll maneuvering and side loading due to pitch and yaw are shown to induce swirling flow. The vortical flow due to roll is symmetrical with respect to the tank centerline, while those induced by pitch and yaw maneuverings showed two vortices side by side. The study found that without the anti-vortex baffle, the swirling flow caused surface dip during the late stage of drainage and hence early vapor ingestion. The flow can also be non-uniform in the drainage pipe as the secondary swirling flow velocity component can be as high as 10% of the draining velocity. An analysis of the vortex dynamics shows that the swirling flow in the drainage pipe during the Upper Stage burn is mainly the result of residual vortices inside the tank due to the conservation of angular momentum. The study demonstrated that the swirling flow in the drainage pipe can be effectively suppressed by employing the anti-vortex baffle.
The migration and growth of nuclei in an ideal vortex flow
NASA Astrophysics Data System (ADS)
Zhang, Lingxin; Chen, Linya; Shao, Xueming
2016-12-01
Tip vortex cavitation occurs on ship propellers which can cause significant noise compared to the wet flow. In order to predict the inception of tip vortex cavitation, numerous researches have been investigated about the detailed flow field around the tip. According to informed studies, the inception of tip vortex cavitation is affected by many factors. To understand the effect of water quality on cavitation inception, the motion of nuclei in an ideal vortex flow, i.e., the Rankine vortex flow, was investigated. The one-way coupling point-particle tracking model was employed to simulate the trajectory of nuclei. Meanwhile, Rayleigh-Plesset equation was introduced to describe the growth of nuclei. The results show that the nucleus size has a significant effect on nucleus' trajectory. The capture time of a nucleus is approximately inversely proportional to its radius. The growth of nucleus accelerates its migration in the vortex flow and shortens its capture time, especially for the case of explosive growth.
RANS Calculations of the Evolution of Vortices on Unstructured Grids
2009-11-01
flow around ship propellers with the goal of being able to model the noise generated from propeller cavitation. Of particular interest is the...axial velocity deficit (left) and radial velocity (right) as a function of r/rci in the plane x = xmid with β = 0.0446...9 Figure 6: Laminar vortex: the pressure coefficient (left) and axial velocity deficit (right) as a function of (x− x0
NASA Technical Reports Server (NTRS)
Borst, H. V.
1978-01-01
A method is presented to design and predict the performance of axial flow rotors operating in a duct. The same method is suitable for the design of ducted fans and open propellers. The unified method is based on the blade element approach and the vortex theory for determining the three dimensional effects, so that two dimensional airfoil data can be used for determining the resultant force on each blade element. Resolution of this force in the thrust and torque planes and integration allows the total performance of the rotor, fan or propeller to be predicted. Three different methods of analysis, one based on a momentum flow theory; another on the vortex theory of propellers; and a third based on the theory of ducted fans, agree and reduce cascade airfoil data to single line as a function of the loading and induced angle of attack at values of constant inflow angle. The theory applies for any solidity from .01 to over 1 and any blade section camber. The effects of the duct and blade number can be determined so that the procedure applies over the entire range from two blade open propellers, to ducted helicopter tail rotors, to axial flow compressors with or without guide vanes, and to wind tunnel drive fans.
3D numerical simulation of transient processes in hydraulic turbines
NASA Astrophysics Data System (ADS)
Cherny, S.; Chirkov, D.; Bannikov, D.; Lapin, V.; Skorospelov, V.; Eshkunova, I.; Avdushenko, A.
2010-08-01
An approach for numerical simulation of 3D hydraulic turbine flows in transient operating regimes is presented. The method is based on a coupled solution of incompressible RANS equations, runner rotation equation, and water hammer equations. The issue of setting appropriate boundary conditions is considered in detail. As an illustration, the simulation results for runaway process are presented. The evolution of vortex structure and its effect on computed runaway traces are analyzed.
Toward modeling wingtip vortices
NASA Technical Reports Server (NTRS)
Zeman, O.
1993-01-01
Wingtip vortices are generated by lifting airfoils; their salient features are compactness and relatively slow rate of decay. The principal motivation for studying the far field evolution of wingtip vortices is the need to understand and predict the extent of the vortex influence during aircraft take-off or landing. On submarines a wingtip vortex ingested into a propeller can be a source of undesirable noise. The main objectives of this research are (1) to establish theoretical understanding of the principal mechanisms that govern the later (diffusive) stages of a turbulent vortex, (2) to develop a turbulence closure model representing the basic physical mechanisms that control the vortex diffusive stage, and further (3) to investigate coupling between the near and far field evolutions; in other words, to study the effect of initial conditions on the vortex lifetime and the ultimate state.
Numerical Investigation of the Flow Structure in a Kaplan Draft Tube at Part Load
NASA Astrophysics Data System (ADS)
Maddahian, R.; Cervantes, M. J.; Sotoudeh, N.
2016-11-01
This research presents numerical simulation of the unsteady flow field inside the draft tube of a Kaplan turbine at part load condition. Due to curvature of streamlines, the ordinary two-equations turbulence models fail to predict the flow features. Therefore, a modification of the Shear Stress Transport (SST-SAS) model is utilized to approximate the turbulent stresses. A guide vane, complete runner and draft tube are considered to insure the real boundary conditions at the draft tube inlet. The outlet boundary is assumed to discharge into the atmosphere. The obtained pressure fluctuations inside the draft tube are in good agreement with available experimental data. In order to further investigate the RVR formation and its movement, the λ2 criterion, relating the position of the vortex core and strength to the second largest Eigen value of the velocity gradient tensor, is employed. The method used for vortex identification shows the flow structure and vortex motion inside the draft tube accurately.
A Non-linear Lifting Line Model for Design and Analysis of Trochoidal Propulsors
NASA Astrophysics Data System (ADS)
Roesler, Bernard; Epps, Brenden
2014-11-01
Flapping wing propulsors may increase the propulsive efficiency of large shipping vessels. A comparison of the design of a notional propulsor for a large shipping vessel with (a) a conventional ducted propeller versus (b) a flapping wing propulsor is presented. Calculations for flapping wing propulsors are performed using an open-source MATLAB software suite developed by the authors, CyROD, implementing an unsteady lifting-line model with free vortex wake roll-up to study the non-linear effects of foil-wake, and foil-foil interactions. Improvements to the traditional lifting line theory are made using further discretization of the wake vortex ring spacing near the trailing edge. Considerations of packaging options for a flapping wing propulsor on a large shipping vessel are presented, and compared with those for a conventional ducted propeller.
NASA Astrophysics Data System (ADS)
Rivetti, A.; Angulo, M.; Lucino, C.; Liscia, S.
2015-12-01
Tip leakage vortex cavitation in axial hydro-turbines may cause erosion, noise and vibration. Damage due to cavitation can be found at the tip of the runner blades on the low pressure side and the discharge ring. In some cases, the erosion follows an oscillatory pattern that is related to the number of guide vanes. That might suggest that a relationship exists between the flow through the guide vanes and the tip vortex cavitating core that induces this kind of erosion. On the other hand, it is known that air injection has a beneficial effect on reducing the damage by cavitation. In this paper, a methodology to identify the interaction between guide vanes and tip vortex cavitation is presented and the effect of air injection in reducing this particular kind of erosion was studied over a range of operating conditions on a Kaplan scale model. It was found that air injection, at the expense of slightly reducing the efficiency of the turbine, mitigates the erosive potential of tip leakage cavitation, attenuates the interaction between the flow through the guide vanes and the tip vortex and decreases the level of vibration of the structural components.
NASA Astrophysics Data System (ADS)
Kawai, H.; Yasui, S.; Takahashi, H.; Kikura, H.; Aritomi, M.
2009-02-01
This study focuses on the dynamics of the Taylor-Couette Vortex Flow (TVF) in a photo-bioreactor in which CO2 is changed to O2 with high efficiency by the photosynthesis ability of micro algae. Stirring by means of a screw propeller is generally used for a simple agitation. However, the problem is that there exists a very high shearing flow region just near the propeller, which causes the destruction of the alga cell by the shearing force. In contrast, the TVF mixing is expected to reduce such a local and random shearing force because of their column of steady and orderly vortices. In this study, the relationship between the microorganism growth rate and the flow structures in dilute suspensions of a TVF is investigated and the flow characteristics are measured by using an ultrasonic velocity profiler with a small aspect ratio of 3.
Handedness helps homing in swimming and flying animals.
Bandyopadhyay, Promode R; Leinhos, Henry A; Hellum, Aren M
2013-01-01
Swimming and flying animals rely on their ability to home on mobile targets. In some fish, physiological handedness and homing correlate, and dolphins exhibit handedness in their listening response. Here, we explore theoretically whether the actuators, sensors, and controllers in these animals follow similar laws of self-regulation, and how handedness affects homing. We find that the acoustic sensor (combined hydrophone-accelerometer) response maps are similar to fin force maps-modeled by Stuart-Landau oscillators-allowing localization by transitional vortex-propelled animals. The planar trajectories of bats in a room filled with obstacles are approximately reproduced by the states of a pair of strong and weak olivo-cerebellar oscillators. The stereoscopy of handedness reduces ambiguity near a mobile target, resulting in accelerated homing compared to even-handedness. Our results demonstrate how vortex-propelled animals may be localizing each other and circumventing obstacles in changing environments. Handedness could be useful in time-critical robot-assisted rescues in hazardous environments.
Runners do not push off the ground but fall forwards via a gravitational torque.
Romanov, Nicholas; Fletcher, Graham
2007-09-01
The relationship between the affect and timing of the four forces involved in running (gravity, ground reaction force, muscle force, and potential strain energy) is presented. These forces only increase horizontal acceleration of the centre of mass during stance but not flight. The current hierarchical models of running are critiqued because they do not show gravity, a constant force, in affect during stance. A new gravitational model of running is developed, which shows gravity as the motive force. Gravity is shown to cause a torque as the runner's centre of mass moves forward of the support foot. Ground reaction force is not a motive force but operates according to Newton's third law; therefore, the ground can only propel a runner forward in combination with muscle activity. However, leg and hip extensor muscles have consistently proven to be silent during leg extension (mid-terminal stance). Instead, high muscle-tendon forces at terminal stance suggest elastic recoil regains most of the centre of mass's height. Therefore, the only external motive force from mid-terminal stance is gravity via a gravitational torque, which causes a horizontal displacement. The aim of this paper is to establish a definitive biomechanical technique (Pose method) that is easily taught to runners (Romanov, 2002): falling forwards via a gravitational torque while pulling the support foot rapidly from the ground using the hamstring muscles.
Numerical study on the hydrodynamics of thunniform bio-inspired swimming under self-propulsion.
Li, Ningyu; Liu, Huanxing; Su, Yumin
2017-01-01
Numerical simulations are employed to study the hydrodynamics of self-propelled thunniform swimming. The swimmer is modeled as a tuna-like flexible body undulating with kinematics of thunniform type. The wake evolution follows the vortex structures arranged nearly vertical to the forward direction, vortex dipole formation resulting in the propulsion motion, and finally a reverse Kármán vortex street. We also carry out a systematic parametric study of various aspects of the fluid dynamics behind the freely swimming behavior, including the swimming speed, hydrodynamic forces, power requirement and wake vortices. The present results show that the fin thrust as well as swimming velocity is an increasing function of both tail undulating amplitude Ap and oscillating amplitude of the caudal fin θm. Whereas change on the propulsive performance with Ap is associated with the strength of wake vortices and the area of suction region on the fin, the swimming performance improves with θm due to the favorable tilting of the fin that make the pressure difference force more oriented toward the thrust direction. Moreover, the energy loss in the transverse direction and the power requirement increase with Ap but decrease with θm, and this indicates that for achieving a desired swimming speed increasing θm seems more efficiently than increasing Ap. Furthermore, we have compared the current simulations with the published experimental studies on undulatory swimming. Comparisons show that our work tackles the flow regime of natural thunniform swimmers and follows the principal scaling law of undulatory locomotion reported. Finally, this study enables a detailed quantitative analysis, which is difficult to obtain by experiments, of the force production of the thunniform mode as well as its connection to the self-propelled swimming kinematics and vortex wake structure. The current findings help provide insights into the swimming performance and mechanisms of self-propelled thunniform locomotion.
Numerical study on the hydrodynamics of thunniform bio-inspired swimming under self-propulsion
Li, Ningyu; Liu, Huanxing
2017-01-01
Numerical simulations are employed to study the hydrodynamics of self-propelled thunniform swimming. The swimmer is modeled as a tuna-like flexible body undulating with kinematics of thunniform type. The wake evolution follows the vortex structures arranged nearly vertical to the forward direction, vortex dipole formation resulting in the propulsion motion, and finally a reverse Kármán vortex street. We also carry out a systematic parametric study of various aspects of the fluid dynamics behind the freely swimming behavior, including the swimming speed, hydrodynamic forces, power requirement and wake vortices. The present results show that the fin thrust as well as swimming velocity is an increasing function of both tail undulating amplitude Ap and oscillating amplitude of the caudal fin θm. Whereas change on the propulsive performance with Ap is associated with the strength of wake vortices and the area of suction region on the fin, the swimming performance improves with θm due to the favorable tilting of the fin that make the pressure difference force more oriented toward the thrust direction. Moreover, the energy loss in the transverse direction and the power requirement increase with Ap but decrease with θm, and this indicates that for achieving a desired swimming speed increasing θm seems more efficiently than increasing Ap. Furthermore, we have compared the current simulations with the published experimental studies on undulatory swimming. Comparisons show that our work tackles the flow regime of natural thunniform swimmers and follows the principal scaling law of undulatory locomotion reported. Finally, this study enables a detailed quantitative analysis, which is difficult to obtain by experiments, of the force production of the thunniform mode as well as its connection to the self-propelled swimming kinematics and vortex wake structure. The current findings help provide insights into the swimming performance and mechanisms of self-propelled thunniform locomotion. PMID:28362836
NASA Technical Reports Server (NTRS)
Ormsbee, A. I.; Bragg, M. B.; Maughmer, M. D.
1981-01-01
A set of relationships used to scale small sized dispersion studies to full size results are experimentally verified and, with some qualifications, basic deposition patterns are presented. In the process of validating these scaling laws, the basic experimental techniques used in conducting such studies both with and without an operational propeller were developed. The procedures that evolved are outlined in some detail. The envelope of test conditions that can be accommodated in the Langley Vortex Research Facility, which were developed theoretically, are verified using a series of vortex trajectory experiments that help to define the limitations due to wall interference effects for models of different sizes.
NASA Astrophysics Data System (ADS)
Gomes, J.; Favrel, A.; Landry, C.; Nicolet, C.; Avellan, F.
2017-04-01
Francis turbines operating in part load conditions experience a swirling flow at the runner outlet leading to the development of a precessing cavitation vortex rope in the draft tube. This cavitation vortex rope changes drastically the velocity of pressure waves traveling in the draft tube and may lead to resonance conditions in the hydraulic circuit. The wave speed being strongly related to the cavitation compliance, this research work presents a simple model to explain how it is affected by variations of operating conditions and proposes a method to transpose its values. Even though the focus of this paper is on transpositions within the same turbine scale, the methodology is also expected to be tested for the model to prototype transposition in the future. Comparisons between measurements and calculations are in good agreement.
Effect of centerbody scattering on propeller noise
NASA Technical Reports Server (NTRS)
Glegg, Stewart A. L.
1991-01-01
This paper describes how the effect of acoustic scattering from the hub or centerbody of a propeller will affect the far-field noise levels. A simple correction to Gutin's formula for steady loading noise is given. This is a maximum for the lower harmonics but has a negligible effect on the higher frequency components that are important subjectively. The case of a blade vortex interaction is also considered, and centerbody scattering is shown to have a significant effect on the acoustic far field.
Effects of a Forward-swept Front Rotor on the Flowfield of a Counterrotation Propeller
NASA Technical Reports Server (NTRS)
Nallasamy, M.; Podboy, Gary G.
1994-01-01
The effects of a forward-swept front rotor on the flowfield of a counterrotation model propeller at takeoff conditions at zero degree angle of attack are studied by solving the unsteady three-dimensional Euler equations. The configuration considered is an uneven blade count counterrotation model with twelve forward-swept blades on the fore rotor and ten aft-swept blades on the aft rotor. The flowfield is compared with that of a reference aft-swept counterrotation geometry and Laser Doppler Velocimeter (LDV) measurements. At the operating conditions considered, the forward-swept blade experiences a higher tip loading and produces a stronger tip vortex compared to the aft-swept blade, consistent with the LDV and acoustic measurements. Neither the solution nor the LDV data indicated the formation of a leading edge vortex. The predicted radial distribution of the circumferentially averaged axial velocity at the measurement station agreed very closely with LDV data, while crossflow velocities showed poor agreement. The discrepancy between prediction and LDV data of tangential and radial velocities is due in part to the insufficient mesh resolution in the region between the rotors and in the tip region to track the tip vortex. The vortex is diffused by the time it arrives at the measurement station. The uneven blade count configuration requires the solution to be carried out for six blade passages of the fore rotor and five passages of the aft rotor, thus making grid refinement prohibitive.
Effect of cavitation on flow structure of a tip vortex
NASA Astrophysics Data System (ADS)
Matthieu, Dreyer; Reclari, Martino; Farhat, Mohamed
2013-11-01
Tip vortices, which may develop in axial turbines and marine propellers, are often associated with the occurrence of cavitation because of the low pressure in their core. Although this issue has received a great deal of attention, it is still unclear how the phase transition affects the flow structure of such a vortex. In the present work, we investigate the change of the vortex structure due to cavitation incipience. The measurement of the velocity field is performed in the case of a tip vortex generated by an elliptical hydrofoil placed in the test section of EPFL high speed cavitation tunnel. To this end, a 3D stereo PIV is used with fluorescent seeding particles. A cost effective method is developed to produce in-house fluorescent seeding material, based on polyamide particles and Rhodamine-B dye. The amount of cavitation in the vortex core is controlled by the inlet pressure in the test section, starting with the non-cavitating case. We present an extensive analysis of the vorticity distribution, the vortex intensity and core size for various cavitation developments. This research is supported by CCEM and swisselectric research.
Vortex Core Size in the Rotor Near-Wake
NASA Technical Reports Server (NTRS)
Young, Larry A.
2003-01-01
Using a kinetic energy conservation approach, a number of simple analytic expressions are derived for estimating the core size of tip vortices in the near-wake of rotors in hover and axial-flow flight. The influence of thrust, induced power losses, advance ratio, and vortex structure on rotor vortex core size is assessed. Experimental data from the literature is compared to the analytical results derived in this paper. In general, three conclusions can be drawn from the work in this paper. First, the greater the rotor thrust, t h e larger the vortex core size in the rotor near-wake. Second, the more efficient a rotor is with respect to induced power losses, the smaller the resulting vortex core size. Third, and lastly, vortex core size initially decreases for low axial-flow advance ratios, but for large advance ratios core size asymptotically increases to a nominal upper limit. Insights gained from this work should enable improved modeling of rotary-wing aerodynamics, as well as provide a framework for improved experimental investigations of rotor a n d advanced propeller wakes.
Vortex Formation and Acceleration of a Fish-Inspired Robot Performing Starts from Rest
NASA Astrophysics Data System (ADS)
Devoria, Adam; Bapst, Jonathan; Ringuette, Matthew
2009-11-01
We investigate the unsteady flow of a fish-inspired robot executing starts from rest, with the objective of understanding the connection among the kinematics, vortex formation, and acceleration performance. Several fish perform ``fast starts,'' where the body bends into a ``C'' or ``S'' shape while turning (phase I), followed by a straightening of the body and caudal fin and a linear acceleration (phase II). The resulting highly 3-D, unsteady vortex formation and its relationship to the acceleration are not well understood. The self-propelled robotic model contains motor-driven joints with programmable motion to emulate phase II of a simplified C-start. The experiments are conducted in a water tank, and the model is constrained to 1 direction along rails. The velocity is measured using digital particle image velocimetry (DPIV) in multiple planes. Vortex boundaries are identified using the finite-time Lyapunov exponent, then the unsteady vortex circulation is computed. The thrust is estimated from the identified vortices, and correlated with the circulation and model acceleration for different kinematics.
Mitigation of tip vortex cavitation by means of air injection on a Kaplan turbine scale model
NASA Astrophysics Data System (ADS)
Rivetti, A.; Angulo, M.; Lucino, C.; Liscia, S.
2014-03-01
Kaplan turbines operating at full-load conditions may undergo excessive vibration, noise and cavitation. In such cases, damage by erosion associated to tip vortex cavitation can be observed at the discharge ring. This phenomenon involves design features such as (1) overhang of guide vanes; (2) blade profile; (3) gap increasing size with blade opening; (4) suction head; (5) operation point; and (6) discharge ring stiffness, among others. Tip vortex cavitation may cause erosion at the discharge ring and draft tube inlet following a wavy pattern, in which the number of vanes can be clearly identified. Injection of pressurized air above the runner blade centerline was tested as a mean to mitigate discharge ring cavitation damage on a scale model. Air entrance was observed by means of a high-speed camera in order to track the air trajectory toward its mergence with the tip vortex cavitation core. Post-processing of acceleration signals shows that the level of vibration and the RSI frequency amplitude decrease proportionally with air flow rate injected. These findings reveal the potential mitigating effect of air injection in preventing cavitation damage and will be useful in further tests to be performed on prototype, aiming at determining the optimum air flow rate, size and distribution of the injectors.
Mind the gap - tip leakage vortex in axial turbines
NASA Astrophysics Data System (ADS)
Dreyer, M.; Decaix, J.; Münch-Alligné, C.; Farhat, M.
2014-03-01
The tendency of designing large Kaplan turbines with a continuous increase of output power is bringing to the front the cavitation erosion issue. Due to the flow in the gap between the runner and the discharge ring, axial turbine blades may develop the so called tip leakage vortex (TLV) cavitation with negative consequences. Such vortices may interact strongly with the wake of guide vanes leading to their multiple collapses and rebounds. If the vortex trajectory remains close to the blade tip, these collapses may lead to severe erosion. One is still unable today to predict its occurrence and development in axial turbines with acceptable accuracy. Numerical flow simulations as well as the actual scale-up rules from small to large scales are unreliable. The present work addresses this problematic in a simplified case study representing TLV cavitation to better understand its sensitivity to the gap width. A Naca0009 hydrofoil is used as a generic blade in the test section of EPFL cavitation tunnel. A sliding mounting support allowing an adjustable gap between the blade tip and wall was manufactured. The vortex trajectory is visualized with a high speed camera and appropriate lighting. The three dimensional velocity field induced by the TLV is investigated using stereo particle image velocimetry. We have taken into account the vortex wandering in the image processing to obtain accurate measurements of the vortex properties. The measurements were performed in three planes located downstream of the hydrofoil for different values of the flow velocity, the incidence angle and the gap width. The results clearly reveal a strong influence of the gap width on both trajectory and intensity of the tip leakage vortex.
Space and time reconstruction of the precessing vortex core in Francis turbine draft tube by 2D-PIV
NASA Astrophysics Data System (ADS)
Favrel, A.; Müller, A.; Landry, C.; Yamamoto, K.; Avellan, F.
2016-11-01
Francis turbines operating at part load conditions experience the development of a high swirling flow at the runner outlet, giving rise to the development of a cavitation precessing vortex rope in the draft tube. The latter acts as an excitation source for the hydro-mechanical system and may jeopardize the system stability if resonance conditions are met. Although many aspects of the part load issue have been widely studied in the past, the accurate stability analysis of hydro-power plants remains challenging. A better understanding of the vortex rope dynamics in a wide range of operating conditions is an important step towards the prediction and the transposition of the pressure fluctuations from reduced to prototype scale. For this purpose, an investigation of the flow velocity fields at the outlet of a Francis turbine reduced scale physical model operating at part load conditions is performed by means of 2D-PIV in three different horizontal cross-sections of the draft tube cone. The measurements are performed in cavitation-free conditions for three values of discharge factor, comprised between 60% and 81% of the value at the Best Efficiency Point. The present article describes a detailed methodology to properly recover the evolution of the velocity fields during one precession cycle by means of phase averaging. The vortex circulation is computed and the vortex trajectory over one typical precession period is finally recovered for each operating point. It is notably shown that below a given value of the discharge factor, the vortex dynamics abruptly change and loose its periodicity and coherence.
NASA Astrophysics Data System (ADS)
Bergan, Carl; Goyal, Rahul; Cervantes, Michel J.; Dahlhaug, Ole G.
2016-11-01
Francis-99 is a set of workshops aiming to determine the state of the art of high head Francis turbine simulations (flow and structure) under steady and transient operating conditions as well as promote their development and knowledge dissemination openly. The first workshop (Trondheim, 2014) focused on steady state conditions. Some concerns were raised regarding uncertainty in the measurements, mainly that there was no clear vortex rope at the Part Load (PL) condition, and that the flow exhibited relatively large asymmetry. The present paper addresses these concerns in order to ensure the quality of the data presented in further workshops. To answer some of these questions, a new set of measurements were performed on the Francis- 99 model at Waterpower Laboratory at the Norwegian University of Science and Technology (NTNU). In addition to PL, two other operating conditions were considered, for further use in transient measurements, Best Efficiency (BEP) and High Load (HL). The experiments were carried out at a head of 12 m, with a runner rotational speed of 333 revolutions per minute (rpm). The guide vane opening angle were 6.72°, 9.84° and 12.43° for PL, BEP and HL, respectively. The part load condition has been changed from the first workshop, to ensure a fully developed Rotating Vortex Rope (RVR). The velocity and pressure measurements were carried out in the draft tube cone using 2D PIV and six pressure sensors, respectively. The new PL condition shows a fully developed rotating vortex rope (RVR) in both the frequency analysis and in the phase resolved data. In addition, the measurements confirm an asymmetric flow leaving the runner, as was a concern in the first Francis-99 workshop. This asymmetry was detected at both design and off-design conditions, with a stronger effect during off design.
LES of a ducted propeller with rotor and stator in crashback
NASA Astrophysics Data System (ADS)
Jang, Hyunchul; Mahesh, Krishnan
2012-11-01
A sliding interface method is developed for large eddy simulation (LES) of flow past ducted propellers with both rotor and stator. The method is developed for arbitrarily shaped unstructured elements on massively parallel computing platforms. Novel algorithms for searching sliding elements, interpolation at the sliding interface, and data structures for message passing are developed. We perform LES of flow past a ducted propeller with stator blades in the crashback mode of operation, where a marine vessel is quickly decelerated by rotating the propeller in reverse. The unsteady loads predicted by LES are in good agreement with experiments. A highly unsteady vortex ring is observed outside the duct. High pressure fluctuations are observed near the blade tips, which significantly contribute to the side-force. This work is supported by the United States Office of Naval Research.
Handedness helps homing in swimming and flying animals
Bandyopadhyay, Promode R.; Leinhos, Henry A.; Hellum, Aren M.
2013-01-01
Swimming and flying animals rely on their ability to home on mobile targets. In some fish, physiological handedness and homing correlate, and dolphins exhibit handedness in their listening response. Here, we explore theoretically whether the actuators, sensors, and controllers in these animals follow similar laws of self-regulation, and how handedness affects homing. We find that the acoustic sensor (combined hydrophone-accelerometer) response maps are similar to fin force maps—modeled by Stuart-Landau oscillators—allowing localization by transitional vortex-propelled animals. The planar trajectories of bats in a room filled with obstacles are approximately reproduced by the states of a pair of strong and weak olivo-cerebellar oscillators. The stereoscopy of handedness reduces ambiguity near a mobile target, resulting in accelerated homing compared to even-handedness. Our results demonstrate how vortex-propelled animals may be localizing each other and circumventing obstacles in changing environments. Handedness could be useful in time-critical robot-assisted rescues in hazardous environments. PMID:23350035
NASA Technical Reports Server (NTRS)
Woodward, Richard P.
1990-01-01
Two modern high-speed advanced counterrotation propellers, F7/A7 and F7/A3 were tested in the NASA Lewis Research Center's 9- by 15-Foot Anechoic Wind Tunnel at simulated takeoff/approach conditions of 0.2 Mach. Both rotors were of similar diameter on the F7/A7 propeller, while the aft diameter of the F7/A3 propeller was 85 percent of the forward propeller to reduce tip vortex-aft rotor interaction. The two propellers were designed for similar performance. The propellers were tested in both the baseline configuration and installed configuration consisting of a simulated upstream nacelle support pylon and fuselage section. Acoustic measurements were made with a polar microphone probe which recorded sideline directivities at various azimuthal locations. Aerodynamic measurements were also made to establish propeller operating conditions. The propellers were run at initial blade setting angles adjusted to achieve equal forward/aft torque ratios at angle of attack with the pylon and fuselage simulation in place. Data are presented for propeller operation at 80 and 90 percent of design speed (the forward rotor design tip speed was 238 m/sec (780 ft/sec). Both propellers were tested at the maximum rotor-rotor spacing of 14.99 cm (5.90 in.) based on the pitch change axis separation.
NASA Technical Reports Server (NTRS)
Groeneweg, John F.; Bober, Lawrence J.
1990-01-01
Recent results of aerodynamic and acoustic research on both single rotation and counterrotation propellers are reviewed. Data and analytical results are presented for three propellers: SR-7A, the single rotation design used in the NASA Propfan Test Assessment (PTA) flight program; CRP-X1, the initial 5+5 Hamilton Standard counterrotating design; and F7-A7, the 8+8 counterrotating G.E. design used in the proof of concept Unducted Fan (UDF) engine. In addition to propeller efficiencies, cruise and takeoff noise, and blade pressure data, off-design phenomena involving formation of leading edge vortexes are described. Aerodynamic and acoustic computational results derived from 3-D Euler and acoustic radiation codes are presented. Research on unsteady flows which are particularly important for understanding counterrotation interaction noise, unsteady loading effects on acoustics, and flutter or forced response is described. The first results of 3-D unsteady Euler solutions are illustrated for a single rotation propeller at angle of attack and for a counterrotation propeller. Basic experimental and theoretical results from studies on the unsteady aerodynamics of oscillating cascades are outlined.
Detection of cavitation vortex in hydraulic turbines using acoustic techniques
NASA Astrophysics Data System (ADS)
Candel, I.; Bunea, F.; Dunca, G.; Bucur, D. M.; Ioana, C.; Reeb, B.; Ciocan, G. D.
2014-03-01
Cavitation phenomena are known for their destructive capacity in hydraulic machineries and are caused by the pressure decrease followed by an implosion when the cavitation bubbles find an adverse pressure gradient. A helical vortex appears in the turbine diffuser cone at partial flow rate operation and can be cavitating in its core. Cavity volumes and vortex frequencies vary with the under-pressure level. If the vortex frequency comes close to one of the eigen frequencies of the turbine, a resonance phenomenon may occur, the unsteady fluctuations can be amplified and lead to important turbine and hydraulic circuit damage. Conventional cavitation vortex detection techniques are based on passive devices (pressure sensors or accelerometers). Limited sensor bandwidths and low frequency response limit the vortex detection and characterization information provided by the passive techniques. In order to go beyond these techniques and develop a new active one that will remove these drawbacks, previous work in the field has shown that techniques based on acoustic signals using adapted signal content to a particular hydraulic situation, can be more robust and accurate. The cavitation vortex effects in the water flow profile downstream hydraulic turbines runner are responsible for signal content modifications. Basic signal techniques use narrow band signals traveling inside the flow from an emitting transducer to a receiving one (active sensors). Emissions of wide band signals in the flow during the apparition and development of the vortex embeds changes in the received signals. Signal processing methods are used to estimate the cavitation apparition and evolution. Tests done in a reduced scale facility showed that due to the increasing flow rate, the signal -- vortex interaction is seen as modifications on the received signal's high order statistics and bandwidth. Wide band acoustic transducers have a higher dynamic range over mechanical elements; the system's reaction time is reduced, resulting in a faster detection of the unwanted effects. The paper will present an example of this new investigation technique on a vortex generator in the test facility that belongs to ICPE- CA.
Vortex Formation in the Wake of Dark Matter Propulsion
NASA Astrophysics Data System (ADS)
Robertson, G. A.; Pinheiro, M. J.
Future spaceflight will require a new theory of propulsion; specifically one that does not require mass ejection. A new theory is proposed that uses the general view that closed currents pervade the entire universe and, in particular, there is a cosmic mechanism to expel matter to large astronomical distances involving vortex currents as seen with blazars and blackholes. At the terrestrial level, force producing vortices have been related to the motion of wings (e.g., birds, duck paddles, fish's tail). In this paper, vortex structures are shown to exist in the streamlines aft of a spaceship moving at high velocity in the vacuum. This is accomplished using the density excitation method per a modified Chameleon Cosmology model. This vortex structure is then shown to have similarities to spacetime models as Warp-Drive and wormholes, giving rise to the natural extension of Hawking and Unruh radiation, which provides the propulsive method for space travel where virtual electron-positron pairs, absorbed by the gravitational expansion forward of the spaceship emerge from an annular vortex field aft of the spaceship as real particles, in-like to propellant mass ejection in conventional rocket theory.
Dynamics of Isolated Tip Vortex Cavitation
NASA Astrophysics Data System (ADS)
Pennings, Pepijn; Bosschers, Johan; van Terwisga, Tom
2014-11-01
Performance of ship propellers and comfort levels in the surroundings are limited by various forms of cavitation. Amongst these forms tip vortex cavitation is one of the first appearing forms and is expected to be mainly responsible for the emission of broadband pressure fluctuations typically occurring between the 4th to the 7th blade passing frequency (approx. 40--70 Hz). These radiated pressure pulses are likely to excite parts of the hull structure resulting in a design compromise between efficiency and comfort. Insight is needed in the mechanism of acoustic emission from the oscillations by a tip vortex cavity. In the current experimental study the tip vortex cavity from a blade with an elliptic planform and sections based on NACA 662 - 415 with meanline a = 0 . 8 is observed using high speed shadowgraphy in combination with blade force and acoustic measurements. An analytic model describing three main cavity deformation modes is verified and used to explain the origin of a cavity eigenfrequency or ``vortex singing'' phenomenon observed by Maines and Arndt (1997) on the tip vortex cavity originating from the same blade. As no hydrodynamic sound originating from the tip vortex cavity was observed it is posed that a tip flow instability is essential for ``vortex singing.'' This research was funded by the Lloyd's Register Foundation as part of the International Institute for Cavitation Research.
Propeller noise caused by blade tip radial forces
NASA Technical Reports Server (NTRS)
Hanson, D. B.
1986-01-01
New experimental evidence which indicates the presence of leading edge and tip edge vortex flow on Prop-Fans is examined, and performance and noise consequences are addressed. It was shown that the tip edge vortex is a significant noise source, particularly for unswept Prop-Fan blades. Preliminary calculations revealed that the addition of the tip side edge source to single rotation Prop-Fans during take off conditions improved the agreement between experiment and theory at blade passing frequency. At high-speed conditions such as the Prop-Fan cruise point, the tip loading effect tends to cancel thickness noise.
Emergent Vortex Patterns in Systems of Self-Propelled, Chiral Particles
NASA Astrophysics Data System (ADS)
Huber, Lorenz; Denk, Jonas; Reithmann, Emanuel; Frey, Erwin
Self-organization of FtsZ polymers is vital for Z-ring assembly during bacterial cell division, and has been studied using reconstituted in vitro model systems. Employing Brownian dynamics simulations and a Boltzmann approach, we model FtsZ polymers as active particles moving along chiral circular paths. With both theoretical approaches we find self-organization into vortex structures and characterize different states in parameter states. Our work demonstrates that these patterns are robust and are generic for active chiral matter. Moreover, we show that the dynamics at the onset of pattern formation is described by a generalized complex Ginzburg-Landau equation.
NASA Astrophysics Data System (ADS)
Usui, Yuta; Kanemoto, Toshiaki; Hiraki, Koju
2013-12-01
The authors have invented the unique counter-rotating type tidal stream power unit composed of the tandem propellers and the double rotational armature type peculiar generator without the traditional stator. The front and the rear propellers counter-drive the inner and the outer armatures of the peculiar generator, respectively. The unit has the fruitful advantages that not only the output is sufficiently higher without supplementary equipment such as a gearbox, but also the rotational moment hardly act on the pillar because the rotational torque of both propellers/armatures are counter-balanced in the unit. This paper discusses experimentally the performances of the power unit and the effects of the propeller rotation on the sea surface. The axial force acting on the pillar increases naturally with the increase of not only the stream velocity but also the drag of the tandem propellers. Besides, the force vertical to the stream also acts on the pillar, which is induced from the Karman vortex street and the dominant frequencies appear owing to the front and the rear propeller rotations. The propeller rotating in close to the sea surface brings the abnormal wave and the amplitude increases as the stream velocity is faster and/or the drag is stronger.
Large Eddy Simulation of Crashback in Marine Propulsors
NASA Astrophysics Data System (ADS)
Jang, Hyunchul
Crashback is an operating condition to quickly stop a propelled vehicle, where the propeller is rotated in the reverse direction to yield negative thrust. The crashback condition is dominated by the interaction of the free stream flow with the strong reverse flow. This interaction forms a highly unsteady vortex ring, which is a very prominent feature of crashback. Crashback causes highly unsteady loads and flow separation on the blade surface. The unsteady loads can cause propulsor blade damage, and also affect vehicle maneuverability. Crashback is therefore well known as one of the most challenging propeller states to analyze. This dissertation uses Large-Eddy Simulation (LES) to predict the highly unsteady flow field in crashback. A non-dissipative and robust finite volume method developed by Mahesh et al. (2004) for unstructured grids is applied to flow around marine propulsors. The LES equations are written in a rotating frame of reference. The objectives of this dissertation are: (1) to understand the flow physics of crashback in marine propulsors with and without a duct, (2) to develop a finite volume method for highly skewed meshes which usually occur in complex propulsor geometries, and (3) to develop a sliding interface method for simulations of rotor-stator propulsor on parallel platforms. LES is performed for an open propulsor in crashback and validated against experiments performed by Jessup et al. (2004). The LES results show good agreement with experiments. Effective pressures for thrust and side-force are introduced to more clearly understand the physical sources of thrust and side-force. Both thrust and side-force are seen to be mainly generated from the leading edge of the suction side of the propeller. This implies that thrust and side-force have the same source---the highly unsteady leading edge separation. Conditional averaging is performed to obtain quantitative information about the complex flow physics of high- or low-amplitude events. The events for thrust and side force show the same tendency. The conditional averages show that during high amplitude events, the vortex ring core is closer to the propeller blades, the reverse flow induced by the propeller rotation is lower, the forward flow is higher at the root of the blades, and leading and trailing edge flow separations are larger. The instantaneous flow field shows that during low amplitude events, the vortex ring is more axisymmetric and the stronger reverse flow induced by the vortex ring suppresses the forward flow so that flow separation on the blades is smaller. During high amplitude events, the vortex ring is less coherent and the weaker reverse flow cannot overcome the forward flow. The stronger forward flow makes flow separation on the blades larger. The effect of a duct on crashback is studied with LES. Thrust mostly arises from the blade surface, but most of side-force is generated from the duct surface. Both mean and RMS of pressure are much higher on inner surface of duct, especially near blade tips. This implies that side-force on the ducted propulsor is caused by the blade-duct interaction. Strong tip leakage flow is observed behind the suction side at the tip gap. The physical source of the tip leakage flow is seen to be the large pressure difference between pressure and suction sides. The conditional average for high amplitude event shows consistent results; the tip leakage flow and pressure difference are significantly higher when thrust and side-force are higher. A sliding interface method is developed to allow simulations of rotor-stator propulsor in crashback. The method allows relative rotations between different parts of the computational grid. Search algorithm for sliding elements, data structures for message passing, and accurate interpolation scheme at the sliding interface are developed for arbitrary shaped unstructured grids on parallel computing platforms. Preliminary simulations of open propulsor in crashback show reasonable performance.
Analogies between oscillation and rotation of bodies induced or influenced by vortex shedding
NASA Astrophysics Data System (ADS)
Lugt, H. J.
Vortex-induced or vortex-influenced rotation and oscillation of bodies in a parallel flow are discussed. A steady flow occurs if the body axis is parallel to the flow or if the axis of rotation is perpendicular to the flow. Flows around an oscillating body are quasi-steady only if the Strougal number is much smaller than unity. The connection between rotation and oscillation is demonstrated in terms of the autorotation of a Lanchester propeller, and conditions for stable autorotation are defined. The Riabouchinsky curve is shown to be typical of forces and torques on bodies with vortical wakes, including situations with fixed body axes perpendicular to the flow. A differential equation is formulated for rotational and oscillating bodies that shed vortices by extending the pendulum equation to include vortical effects expressed as a fifth-order polynomial.
Integral Model of Noise of an Engine-Propeller Power Plant
NASA Astrophysics Data System (ADS)
Moshkov, P. A.; Samokhin, V. F.
2018-03-01
A semiempirical model is proposed for estimation of the noise levels produced by aircraft piston power plants in the far acoustic field, which takes account of the main sources of noise. The acoustic field is considered as a superposition of fields formed by the radiations from a propeller and a piston engine. For calculation estimation of the levels of tonal noise of the propeller, it is proposed that a semiempirical method developed by the authors earlier be used. To determine the levels of vortex propeller noise which is presumably dominant in the broad-band noise of tractor propellers, it is proposed that one analytical model of trailing-edge noise be used. An empirical model of noise is proposed for calculation of the acoustic characteristics of a piston engine. Good agreement is shown between calculated and experimental data on the noise of power plants with tractor propellers. The data have been derived in acoustic testing of light aircraft of the An-2, Yak-18T, MAI-223M, and F30 type under static conditions at the aviabase of the Moscow Aviation Institute. Lines of further research are formulated for improvement of this procedure and expansion of the field of its application.
Integral Model of Noise of an Engine-Propeller Power Plant
NASA Astrophysics Data System (ADS)
Moshkov, P. A.; Samokhin, V. F.
2018-05-01
A semiempirical model is proposed for estimation of the noise levels produced by aircraft piston power plants in the far acoustic field, which takes account of the main sources of noise. The acoustic field is considered as a superposition of fields formed by the radiations from a propeller and a piston engine. For calculation estimation of the levels of tonal noise of the propeller, it is proposed that a semiempirical method developed by the authors earlier be used. To determine the levels of vortex propeller noise which is presumably dominant in the broad-band noise of tractor propellers, it is proposed that one analytical model of trailing-edge noise be used. An empirical model of noise is proposed for calculation of the acoustic characteristics of a piston engine. Good agreement is shown between calculated and experimental data on the noise of power plants with tractor propellers. The data have been derived in acoustic testing of light aircraft of the An-2, Yak-18T, MAI-223M, and F30 type under static conditions at the aviabase of the Moscow Aviation Institute. Lines of further research are formulated for improvement of this procedure and expansion of the field of its application.
Numerical and experimental investigation of conventional and un-conventional preswirl duct for VLCC
NASA Astrophysics Data System (ADS)
Shin, Hyun-Joon; Lee, Jong-Seung; Lee, Kang-Hoon; Han, Myung-Ryun; Hur, Eui-Beom; Shin, Sung-Chul
2013-09-01
This paper shows the study of preswirl duct as an effective energy saving devices that have been devised and reviewed to support the propeller performance, especially for the ship of VLCC with large block coefficients. From the bare hull wake measurements, typical upper/lower asymmetry of hull wake at the propeller disk was found. The 2 kinds of pre-swirl duct, Unconventional half circular duct and Conventional circular pre-swirl duct have been designed and reviewed to recover the loss of propeller running in that condition. The general function of the pre-swirl duct was set to work against this asymmetry of wake and generate pre-swirled flow into the propeller against the propeller rotating direction. The optimum self propulsion tests with various angle configurations were carried out and the best configuration was decided. Accordingly, cavitation test was carried out with best configuration of unconventional half circular duct. The blade surface and tip vortex cavitation behaved smoother when the duct was mounted. The hull pressure amplitudes reflected this difference, so the hull pressure amplitude with duct was smaller than that of without duct.
Numerical Capture of Wing-tip Vortex Using Vorticity Confinement
NASA Astrophysics Data System (ADS)
Zhang, Baili; Lou, Jing; Kang, Chang Wei; Wilson, Alexander; Lundberg, Johan; Bensow, Rickard
2012-11-01
Tracking vortices accurately over large distances is very important in many areas of engineering, for instance flow over rotating helicopter blades, ship propeller blades and aircraft wings. However, due to the inherent numerical dissipation in the advection step of flow simulation, current Euler and RANS field solvers tend to damp these vortices too fast. One possible solution to reduce the unphysical decay of these vortices is the application of vorticity confinement methods. In this study, a vorticity confinement term is added to the momentum conservation equations which is a function of the local element size, the vorticity and the gradient of the absolute value of vorticity. The approach has been evaluated by a systematic numerical study on the tip vortex trailing from a rectangular NACA0012 half-wing. The simulated structure and development of the wing-tip vortex agree well with experiments both qualitatively and quantitatively without any adverse effects on the global flow field. It is shown that vorticity confinement can negate the effect of numerical dissipation, leading to a more or less constant vortex strength. This is an approximate method in that genuine viscous diffusion of the vortex is not modeled, but it can be appropriate for vortex dominant flows over short to medium length scales where viscous diffusion can be neglected.
Effects of superhydrophobic surface on the propeller wake
NASA Astrophysics Data System (ADS)
Choi, Hongseok; Lee, Jungjin; Park, Hyungmin
2017-11-01
This study investigates the change in propeller wake when the superhydrophobic surface is applied on the propeller blade. The propeller rotates in a quiescent water tank, facing its bottom, with a rotational Reynolds number of 96000. To measure the three-dimensional flow fields, we use stereo PIV and a water prism is installed at the camera-side tank wall. Two cameras are tilted 30 degrees from the normal axis of the tank wall, satisfying schiempflug condition. Superhydrophobic surface is made by coating hydrophobic nanoparticles on the propeller blade. Measurements are done on two vertical planes (at the center of propeller hub and the blade tip), and are ensemble averaged being classified by blade phase of 0 and 90 degrees. Velocity fluctuation, turbulent kinetic energy, and vorticity are evaluated. With superhydrophobic surface, it is found that the turbulence level is significantly (20 - 30 %) reduced with a small penalty (less than 5%) in the streamwise momentum (i.e., thrust) generation. This is because the cone shaped propeller wake gets narrower and organized vortex structures are broken with the superhydrophobic surfaces. More detailed flow analysis will be given. Supported by NRF (NRF-2016R1C1B2012775, NRF-2016M2B2A9A02945068) programs of Korea government.
NASA Astrophysics Data System (ADS)
Fedorov, A. V.; Bedarev, I. A.; Lavruk, S. A.; Trushlyakov, V. I.; Kudentsov, V. Yu.
2018-03-01
In the present work, a method of mathematical simulation is employed to describe processes occurring in the specimens of new equipment and using the remaining propellant in rocket-engine tanks. Within the framework of certain turbulence models, the authors perform a calculation of the flow field in the volume of the tank of the launch-vehicle stage when a hot gas jet is injected into it. A vortex flow structure is revealed; the characteristics of heat transfer for different angles of injection of the jet are determined. The obtained correlation Nu = Nu(Re) satisfactorily describes experimental data.
NASA Astrophysics Data System (ADS)
Fedorov, A. V.; Bedarev, I. A.; Lavruk, S. A.; Trushlyakov, V. I.; Kudentsov, V. Yu.
2018-05-01
In the present work, a method of mathematical simulation is employed to describe processes occurring in the specimens of new equipment and using the remaining propellant in rocket-engine tanks. Within the framework of certain turbulence models, the authors perform a calculation of the flow field in the volume of the tank of the launch-vehicle stage when a hot gas jet is injected into it. A vortex flow structure is revealed; the characteristics of heat transfer for different angles of injection of the jet are determined. The obtained correlation Nu = Nu(Re) satisfactorily describes experimental data.
Daphnia swarms: from single agent dynamics to collective vortex formation
NASA Astrophysics Data System (ADS)
Ordemann, Anke; Balazsi, Gabor; Caspari, Elizabeth; Moss, Frank
2003-05-01
Swarm theories have become fashionable in theoretical physics over the last decade. They span the range of interactions from individual agents moving in a mean field to coherent collective motions of large agent populations, such as vortex-swarming. But controlled laboratory tests of these theories using real biological agents have been problematic due primarily to poorly known agent-agent interactions (in the case of e.g. bacteria and slime molds) or the large swarm size (e.g. for flocks of birds and schools of fish). Moreover, the entire range of behaviors from single agent interactions to collective vortex motions of the swarm have here-to-fore not been observed with a single animal. We present the results of well defined experiments with the zooplankton Daphnia in light fields showing this range of behaviors. We interpret our results with a theory of the motions of self-propelled agents in a field.
Sea trials of a ducted tip propeller designed for improved cavitation performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hordnes, I.; Bidaud, A.; Green, S.I.
1994-12-31
Studies have shown that ``ring-wing`` or ``ducted`` tip devices reduce substantially the inception index of trailing vortices generated by a hydrofoil (Green et al. 1988). It has also been shown that these devices improve the lift/drag ratio of an airfoil at high angle of incidence (Duan et al. 1992). These finding indicate that there may be a marine application for the ducted tip. Experimental equipment has been designed and manufactured in preparation for upcoming tests of a propeller with ducted tips. The tips are tubes aligned with the propeller blade tips that will replace a radial fraction of the originalmore » blade tips equal to the diameter of the tubes. The tube dimensions have been chosen according to the span/tip diameter and chord/tip length ratios used by Duan et al. (1992), and the tubes will be given a curvature equal to the propeller tip radius. Field trials will be given a curvature equal to the propeller tip radius. Field trials will be conducted on a 36 inch diameter propeller that is used to propel a 45 ft. fishing (seine) boat operating in the coastal waters outside Vancouver. The performance of the propeller will be measured in terms of the propeller efficiency as a function of advance ratio. A special force transducer has been designed that is capable of recording both torque and thrust on the propeller shaft even though these are expected to produce shaft strains of different orders of magnitude. As a supplementary means of monitoring the propeller performance, a hydrophone will be located near the propeller wake in order to measure the tip vortex cavitation noise.« less
NASA Technical Reports Server (NTRS)
Robotti, A. C.; Oggero, M.
1984-01-01
Experiments which use a new type of arc-jet, characterized by composite electromagnetic and vortex stabilization and propelled by hydrogen and nitrogen in turn are described. The electrical characteristics of the arc and the loss of heat through the electrodes is emphasized.
A Design Tool for Matching UAV Propeller and Power Plant Performance
NASA Astrophysics Data System (ADS)
Mangio, Arion L.
A large body of knowledge is available for matching propellers to engines for large propeller driven aircraft. Small UAV's and model airplanes operate at much lower Reynolds numbers and use fixed pitch propellers so the information for large aircraft is not directly applicable. A design tool is needed that takes into account Reynolds number effects, allows for gear reduction, and the selection of a propeller optimized for the airframe. The tool developed in this thesis does this using propeller performance data generated from vortex theory or wind tunnel experiments and combines that data with an engine power curve. The thrust, steady state power, RPM, and tip Mach number vs. velocity curves are generated. The Reynolds number vs. non dimensional radial station at an operating point is also found. The tool is then used to design a geared power plant for the SAE Aero Design competition. To measure the power plant performance, a purpose built engine test stand was built. The characteristics of the engine test stand are also presented. The engine test stand was then used to characterize the geared power plant. The power plant uses a 26x16 propeller, 100/13 gear ratio, and an LRP 0.30 cubic inch engine turning at 28,000 RPM and producing 2.2 HP. Lastly, the measured power plant performance is presented. An important result is that 17 lbf of static thrust is produced.
Nonlinear Analysis of Two-phase Circumferential Motion in the Ablation Circumstance
NASA Astrophysics Data System (ADS)
Xiao-liang, Xu; Hai-ming, Huang; Zi-mao, Zhang
2010-05-01
In aerospace craft reentry and solid rocket propellant nozzle, thermal chemistry ablation is a complex process coupling with convection, heat transfer, mass transfer and chemical reaction. Based on discrete vortex method (DVM), thermal chemical ablation model and particle kinetic model, a computational module dealing with the two-phase circumferential motion in ablation circumstance is designed, the ablation velocity and circumferential field can be thus calculated. The calculated nonlinear time series are analyzed in chaotic identification method: relative chaotic characters such as correlation dimension and the maximum Lyapunov exponent are calculated, fractal dimension of vortex bulbs and particles distributions are also obtained, thus the nonlinear ablation process can be judged as a spatiotemporal chaotic process.
Velocity field measurements in the wake of a propeller model
NASA Astrophysics Data System (ADS)
Mukund, R.; Kumar, A. Chandan
2016-10-01
Turboprop configurations are being revisited for the modern-day regional transport aircrafts for their fuel efficiency. The use of laminar flow wings is an effort in this direction. One way to further improve their efficiency is by optimizing the flow over the wing in the propeller wake. Previous studies have focused on improving the gross aerodynamic characteristics of the wing. It is known that the propeller slipstream causes early transition of the boundary layer on the wing. However, an optimized design of the propeller and wing combination could delay this transition and decrease the skin friction drag. Such a wing design would require the detailed knowledge of the development of the slipstream in isolated conditions. There are very few studies in the literature addressing the requirements of transport aircraft having six-bladed propeller and cruising at a high propeller advance ratio. Low-speed wind tunnel experiments have been conducted on a powered propeller model in isolated conditions, measuring the velocity field in the vertical plane behind the propeller using two-component hot-wire anemometry. The data obtained clearly resolved the mean velocity, the turbulence, the ensemble phase averages and the structure and development of the tip vortex. The turbulence in the slipstream showed that transition could be close to the leading edge of the wing, making it a fine case for optimization. The development of the wake with distance shows some interesting flow features, and the data are valuable for flow computation and optimization.
NASA Technical Reports Server (NTRS)
Chandrasekaran, B.
1986-01-01
This document is the user's guide for the method developed earlier for predicting the slipstream wing interaction at subsonic speeds. The analysis involves a subsonic panel code (HESS code) modified to handle the propeller onset flow. The propfan slipstream effects are superimposed on the normal flow boundary condition and are applied over the surface washed by the slipstream. The effects of the propeller slipstream are to increase the axial induced velocity, tangential velocity, and a total pressure rise in the wake of the propeller. Principles based on blade performance theory, momentum theory, and vortex theory were used to evaluate the slipstream effects. The code can be applied to any arbitrary three dimensional geometry, expressed in the form of HESS input format. The code can handle a propeller alone configuration or a propeller/nacelle/airframe configuration, operating up to high subcritical Mach numbers over a range of angles of attack. Inclusion of a viscous modelling is briefly outlined. Wind tunnel results/theory comparisons are included as examples for the application of the code to a generic supercritical wing/overwing Nacelle with a powered propfan. A sample input/output listing is provided.
Undulating fins produce off-axis thrust and flow structures.
Neveln, Izaak D; Bale, Rahul; Bhalla, Amneet Pal Singh; Curet, Oscar M; Patankar, Neelesh A; MacIver, Malcolm A
2014-01-15
While wake structures of many forms of swimming and flying are well characterized, the wake generated by a freely swimming undulating fin has not yet been analyzed. These elongated fins allow fish to achieve enhanced agility exemplified by the forward, backward and vertical swimming capabilities of knifefish, and also have potential applications in the design of more maneuverable underwater vehicles. We present the flow structure of an undulating robotic fin model using particle image velocimetry to measure fluid velocity fields in the wake. We supplement the experimental robotic work with high-fidelity computational fluid dynamics, simulating the hydrodynamics of both a virtual fish, whose fin kinematics and fin plus body morphology are measured from a freely swimming knifefish, and a virtual rendering of our robot. Our results indicate that a series of linked vortex tubes is shed off the long edge of the fin as the undulatory wave travels lengthwise along the fin. A jet at an oblique angle to the fin is associated with the successive vortex tubes, propelling the fish forward. The vortex structure bears similarity to the linked vortex ring structure trailing the oscillating caudal fin of a carangiform swimmer, though the vortex rings are distorted because of the undulatory kinematics of the elongated fin.
Takeoff/approach noise for a model counterrotation propeller with a forward-swept upstream rotor
NASA Technical Reports Server (NTRS)
Woodward, Richard P.; Hall, David G.; Podboy, Gary G.; Jeracki, Robert J.
1993-01-01
A scale model of a counterrotating propeller with forward-swept blades in the forward rotor and aft-swept blades in the aft rotor (designated F39/A31) has been tested in the NASA Lewis 9- by 15-Foot Anechoic Wind Tunnel. This paper presents aeroacoustic results at a takeoff/approach condition of Mach 0.20. Laser Doppler Velocimeter results taken in a plane between the two rotors are also included to quantify the interaction flow field. The intention of the forward-swept design is to reduce the magnitude of the forward rotor tip vortex and/or wakes which impinge on the aft rotor, thus lowering the interaction tone levels.
Takeoff/approach noise for a model counterrotation propeller with a forward-swept upstream rotor
NASA Technical Reports Server (NTRS)
Woodward, Richard P.; Hall, David G.; Podboy, Gary G.; Jeracki, Robert J.
1993-01-01
A scale model of a counterrotating propeller with forward-swept blades in the forward rotor and aft-swept blades in the aft rotor (designated F39/A31) has been tested in the NASA Lewis 9- by 15-Foot Anechoic Wind Tunnel. This paper presents aeroacoustic results at a takeoff/approach condition of Mach 0.20. Laser Doppler velocimeter results taken in a plane between the two rotors are also included to quantify the interaction flow field. The intention of the forward-swept design is to reduce the magnitude of the forward rotor tip vortex and/or wakes which impinge on the aft rotor, thus lowering the interaction tone levels. A reference model propeller (designated F31/A31), having aft-swept blades in both rotors, was also tested. Aeroelastic performance of the F39/A31 propeller was disappointing. The forward rotor tip region tended to untwist toward higher effective blade angles under load. The forward rotor also exhibited steady state blade flutter at speeds and loadings well below the design condition. The noise results, based on sideline acoustic data, show that the interaction tone levels were up to 8 dB higher with the forward-swept design compared to those for the reference propeller at similar operating conditions, with these tone level differences extending down to lower propeller speeds where flutter did not occur. These acoustic results are for a poorly-performing forward-swept propeller. It is quite possible that a properly-designed forward-swept propeller would exhibit substantial interaction tone level reductions.
NASA Astrophysics Data System (ADS)
Praetorius, Simon; Voigt, Axel; Wittkowski, Raphael; Löwen, Hartmut
2018-05-01
Two-dimensional crystals on curved manifolds exhibit nontrivial defect structures. Here we consider "active crystals" on a sphere, which are composed of self-propelled colloidal particles. Our work is based on a phase-field-crystal-type model that involves a density and a polarization field on the sphere. Depending on the strength of the self-propulsion, three different types of crystals are found: a static crystal, a self-spinning "vortex-vortex" crystal containing two vortical poles of the local velocity, and a self-translating "source-sink" crystal with a source pole where crystallization occurs and a sink pole where the active crystal melts. These different crystalline states as well as their defects are studied theoretically here and can in principle be confirmed in experiments.
Experimental Investigation of the Unsteady Flow Structures of Two Interacting Pitching Wings
NASA Astrophysics Data System (ADS)
Kurt, Melike; Moored, Keith
2015-11-01
Birds, insects and fish propel themselves with unsteady motions of their wings and fins. Many of these animals are also found to fly or swim in three-dimensional flocks and schools. Numerous studies have explored the three-dimensional steady flow interactions and the two-dimensional unsteady flow interactions in collectives. Yet, the characterization of the three-dimensional unsteady interactions remains relatively unexplored. This study aims to characterize the flow structures and interactions between two sinusoidally pitching finite-span wings. The arrangement of the wings varies from a tandem to a bi-plane configuration. The vortex structures for these various arrangements are quantified by using particle image velocimetry. The vortex-wing interactions are also characterized as the synchrony between the wings is modified.
NASA Technical Reports Server (NTRS)
Woodward, Richard P.; Gordon, Eliott B.
1988-01-01
A model high-speed advanced counterrotation propeller, F7/A3, was tested in the NASA Lewis Research Center 9 by 15 foot Anechoic Wind Tunnel at simulated takeoff/approach conditions of 0.2 Mach number. Acoustic measurements were taken with an axially translating microphone probe, and with a polar microphone probe which was fixed to the propeller nacelle and could take both sideline and circumferential acoustic surveys. Aerodynamic measurements were also made to establish propeller operating conditions. The propeller was run at two setting angles (front angle/rear angle) of 36.4/43.5 and 41.1/46.4 degrees, forward rotor tip speeds from 165 to 259 m/sec, rotor spacings from 8.48 to 14.99 cm based on pitch change axis separation, and angles of attack to 16 degrees. The aft rotor diameter was 85 percent of the forward rotor diameter to reduce tip vortex-aft rotor interaction as a major interaction noise source. Results are compared with equal diameter F7/A7 data which was previously obtained under similar operating conditions. The aft rotor-alone tone was 7 dB lower for the reduced diameter aft rotor, due to reduced tip speed at constant rpm. Interaction tone levels for the F7/A3 propeller were higher at minimum row spacing and lower at maximum spacing.
Propeller performance analysis and multidisciplinary optimization using a genetic algorithm
NASA Astrophysics Data System (ADS)
Burger, Christoph
A propeller performance analysis program has been developed and integrated into a Genetic Algorithm for design optimization. The design tool will produce optimal propeller geometries for a given goal, which includes performance and/or acoustic signature. A vortex lattice model is used for the propeller performance analysis and a subsonic compact source model is used for the acoustic signature determination. Compressibility effects are taken into account with the implementation of Prandtl-Glauert domain stretching. Viscous effects are considered with a simple Reynolds number based model to account for the effects of viscosity in the spanwise direction. An empirical flow separation model developed from experimental lift and drag coefficient data of a NACA 0012 airfoil is included. The propeller geometry is generated using a recently introduced Class/Shape function methodology to allow for efficient use of a wide design space. Optimizing the angle of attack, the chord, the sweep and the local airfoil sections, produced blades with favorable tradeoffs between single and multiple point optimizations of propeller performance and acoustic noise signatures. Optimizations using a binary encoded IMPROVE(c) Genetic Algorithm (GA) and a real encoded GA were obtained after optimization runs with some premature convergence. The newly developed real encoded GA was used to obtain the majority of the results which produced generally better convergence characteristics when compared to the binary encoded GA. The optimization trade-offs show that single point optimized propellers have favorable performance, but circulation distributions were less smooth when compared to dual point or multiobjective optimizations. Some of the single point optimizations generated propellers with proplets which show a loading shift to the blade tip region. When noise is included into the objective functions some propellers indicate a circulation shift to the inboard sections of the propeller as well as a reduction in propeller diameter. In addition the propeller number was increased in some optimizations to reduce the acoustic blade signature.
NASA Astrophysics Data System (ADS)
Wagenhoffer, Nathan; Moored, Keith; Jaworski, Justin
2015-11-01
Animals have evolved flexible wings and fins to efficiently and quietly propel themselves through the air and water. The design of quiet and efficient bio-inspired propulsive concepts requires a rapid, unified computational framework that integrates three essential features: the fluid mechanics, the elastic structural response, and the noise generation. This study focuses on the development, validation, and demonstration of a transient, two-dimensional acoustic boundary element solver accelerated by a fast multipole algorithm. The resulting acoustic solver is used to characterize the acoustic signature produced by a vortex street advecting over a NACA 0012 airfoil, which is representative of vortex-body interactions that occur in schools of swimming fish. Both 2S and 2P canonical vortex streets generated by fish are investigated over the range of Strouhal number 0 . 2 < St < 0 . 4 , and the acoustic signature of the airfoil is quantified. This study provides the first estimate of the noise signature of a school of swimming fish. Lehigh University CORE Grant.
NASA Astrophysics Data System (ADS)
Oweis, Ghanem; Steven, Ceccio
2003-11-01
PIV data of the flow field in the immediate vicinity of the trailing edge of a ducted propeller at the tip revealed the existence of multiple vorticity concentrations. The multiple vortices in each instantaneous PIV field were identified and individually characterized. The measurements of the multiple vortices were combined with a Gaussian vortex model to reconstruct the vorticity and velocity fields. The major features of the original experimental field were recovered, and the correlation between the two fields was good. The time averaged field and velocity fluctuations were also measured. We will discuss why the "typical" instantaneous tip vortex and the tip vortex from the time averaged field are substantially different. We attempt to explain the cause of these differences. Knowledge of the instantaneous flow field variability is used to understand the causes of the measured velocity fluctuations. The results from this study have an impact on the understanding of the roll-up of tip vortices, and the dynamics of multiple vortices.
Influence of wing tip morphology on vortex dynamics of flapping flight
NASA Astrophysics Data System (ADS)
Krishna, Swathi; Mulleners, Karen
2013-11-01
The mechanism of flapping wing flight provides insects with extraordinary flight capabilities. The uniquely shaped wing tips give insects an edge in flight performance and the interaction between the leading edge vortices and wing tip vortices enhance their propelling efficiencies and manoeuvrability. These are qualities that are sought after in current-day Micro Air Vehicles. A detailed understanding of the vortex dynamics of flapping flight and the influence of the wing tip planform is imperative for technical application. An experimental study is conducted to investigate the effects of different wing tip planforms on the formation, evolution and interaction of vortical structures. We thereby focus on the interaction between the coherent structures evolving from the leading edge and the wing tip during pitching and flapping motions.The spatial and temporal evolution of the three-dimensional flow structures are determined using Scanning (Stereo) Particle Image Velocimetry and an in-depth coherent structure analysis. By comparing the vortex dynamics, the aerodynamic performance of various wing tip planforms are evaluated.
NASA Astrophysics Data System (ADS)
Tallapragada, P.; Kelly, S. D.
2015-11-01
Diverse mechanisms for animal locomotion in fluids rely on vortex shedding to generate propulsive forces. This is a complex phenomenon that depends essentially on fluid viscosity, but its influence can be modeled in an inviscid setting by introducing localized velocity constraints to systems comprising solid bodies interacting with ideal fluids. In the present paper, we invoke an unsteady version of the Kutta condition from inviscid airfoil theory and a more primitive stagnation condition to model vortex shedding from a geometrically contrasting pair of free planar bodies representing idealizations of swimming animals or robotic vehicles. We demonstrate with simulations that these constraints are sufficient to enable both bodies to propel themselves with very limited actuation. The solitary actuator in each case is a momentum wheel internal to the body, underscoring the symmetry-breaking role played by vortex shedding in converting periodic variations in a generic swimmer's angular momentum to forward locomotion. The velocity constraints are imposed discretely in time, resulting in the shedding of discrete vortices; we observe the roll-up of these vortices into distinctive wake structures observed in viscous models and physical experiments.
NASA Technical Reports Server (NTRS)
Woodward, Richard P.; Hughes, Christopher E.
1989-01-01
Two modern high-speed advanced counterrotation propellers, F7/A7 and F7/A3 were tested in the NASA Lewis Research Centers's 9- by 15-foot Anechoic Wind Tunnel at simulated takeoff/approach conditions of 0.2 Mach number. Both rotors were of similar diameter on the F7/A7 propeller, while the aft rotor diameter of the F7/A3 propeller was 85 percent of the forward propeller to reduce tip vortex-aft rotor interaction. The two propellers were designed for similar performance. The propellers were tested in both the clean configuration, and installed configuration consisting of a simulated upstream nacelle support pylon and fuselage section. Acoustic measurements were made with an axially translating microphone probe, and with a polar microphone probe which was fixed to the propeller nacelle and could make both sideline and circumferential acoustic surveys. Aerodynamic measurements were also made to establish propeller operating conditions. The propellers were run at blade setting angles (fron angle/rear angle) of 41.1/39.4 deg for the F7/A7 propeller, and 41.1/46.4 deg for the F7/A3 propeller. The forward rotors were tested over a range of tip speeds from 165 to 259 m/sec (540 to 850 ft/sec), and both propellers were tested at the maximum rotor-rotor spacing, based on pitch change axis separation, of 14.99 cm (5.90 in.). The data presented in this paper are for 0 deg propeller axis angle of attack. Results are presented for the baseline, pylon-alone, and strut + fuselage configurations. The presence of the simulated fuselage resulted in higher rotor-alone tone levels in a direction normal to the advancing propeller blade near the fuselage. A corresponding rotor-alone tone reduction was often observed 180 deg circumferentially from this region of increased noise. A significant rotor-alone increase for both rotors was observed diametrically opposite the fuselage. In some cases, interaction tone levels were likewise affected by the simulated installation.
NASA Astrophysics Data System (ADS)
Baris, Engin
Distributed electric propulsion systems benefit from the inherent scale independence of electric propulsion. This property allows the designer to place multiple small electric motors along the wing of an aircraft instead of using a single or several internal combustion motors with gear boxes or other power train components. Aircraft operating at low Reynolds numbers are ideal candidates for benefiting from increased local flow velocities as provided by distributed propulsion systems. In this study, a distributed electric propulsion system made up of eight motor/propellers was integrated into the leading edge of a small fixed wing-body model to investigate the expected improvements on the aerodynamics available to small UAVs operating at low Reynolds numbers. Wind tunnel tests featuring a Design of Experiments (DOE) methodology were used for aerodynamic characterization. Experiments were performed in four modes: all-propellers-on, wing-tip-propellers-alone-on, wing-alone mode, and two-inboard-propellers-on-alone mode. In addition, the all-propeller-on, wing-alone, and a single-tractor configuration were analyzed using VSPAERO, a vortex lattice code, to make comparisons between these different configurations. Results show that the distributed propulsion system has higher normal force, endurance, and range features, despite a potential weight penalty.
On the motion of multiple helical vortices
NASA Astrophysics Data System (ADS)
Wood, D. H.; Boersma, J.
2001-11-01
The analysis of the self-induced velocity of a single helical vortex (Boersma & Wood 1999) is extended to include equally spaced multiple vortices. This arrangement approximates the tip vortices in the far wake of multi-bladed wind turbines, propellers, or rotors in ascending, descending, or hovering flight. The problem is reduced to finding, from the Biot Savart law, the additional velocity of a helix due to an identical helix displaced azimuthally. The resulting Biot Savart integral is further reduced to a Mellin Barnes integral representation which allows the asymptotic expansions to be determined for small and for large pitch. The Biot Savart integral is also evaluated numerically for a total of two, three and four vortices over a range of pitch values. The previous finding that the self-induced velocity at small pitch is dominated by a term inversely proportional to the pitch carries over to multiple vortices. It is shown that a far wake dominated by helical tip vortices is consistent with the one-dimensional representation that leads to the Betz limit on the power output of wind turbines. The small-pitch approximation then allows the determination of the blade&s bound vorticity for optimum power extraction. The present analysis is shown to give reasonable estimates for the vortex circulation in experiments using a single hovering rotor and a four-bladed propeller.
Research of the high performance low temperature vortex street flowmeter
NASA Astrophysics Data System (ADS)
Gao, Feng; Chen, Yang; Zhang, Zhen-peng; Geng, Wei-guo
2007-07-01
Flow measurement is the key method for R&D and operation monitoring of liquid rocket engine. Therefore, it is important to measure flux of low temperature liquid propellants for the liquid hydrogen/liquid oxygen or the liquid oxygen/kerosene rocket engine. Presently in China, the level meter and the turbine flowmeter are usually used in the experimentation of the liquid hydrogen/liquid oxygen rocket engine. The level meter can only scale average flux and the precision of the turbine flowmeter (the measuring wild point is 1.5%) can not be ensured due to the reason which there is not devices of low temperature real-time demarcation in China. Therefore, it is required to research the high performance low temperature flow measurement equipment and the vortex street flowmeter is selected because of its advantages. In the paper, some key techniques of low temperature vortex street flowmeter are researched from the design aspect. Firstly, the basic theoretical research of vortex street flowmeter includes signal detection method, shape of vortex producer and effects of dimension of vertex producer to vortex quality. Secondly, low temperature vortex street flowmeter adopts the method of piezoelectric components stress mode. As for the weakness of phase-change, lattice change and fragility for many piezoelectric materials in low temperature, it can not be fulfilled piezoelectric signal and mechanism performance under this condition. Some piezoelectric materials which can be used in low temperature are illustrated in the paper by lots of research in order for the farther research. The article places emphasis upon low temperature trait of piezoelectric materials, and the structure designs of signal detector and calculation of stress, electric charge quantity and heat transfer.
NASA Technical Reports Server (NTRS)
Martinez, R.; Cole, J. E., III; Martini, K.; Westagard, A.
1987-01-01
Reported calculations of structure-borne cabin noise for a small twin engine aircraft powered by tractor propellers rely on the following three-stage methodological breakup of the problem: (1) the unsteady-aerodynamic prediction of wing lift harmonics caused by the whipping action of the vortex system trailed from each propeller; (2) the associated wing/fuselage structural response; (3) the cabin noise field for the computed wall vibration. The first part--the estimate of airloads--skirts a full-fledged aeroelastic situation by assuming the wing to be fixed in space while cancelling the downwash field of the cutting vortices. The model is based on an approximate high-frequency lifting-surface theory justified by the blade rate and flight Mach number of application. Its results drive a finite-element representation of the wing accounting for upper and lower skin surfaces, spars, ribs, and the presence of fuel. The fuselage, modeled as a frame-stiffened cylindrical shell, is bolted to the wing.
DES Prediction of Cavitation Erosion and Its Validation for a Ship Scale Propeller
NASA Astrophysics Data System (ADS)
Ponkratov, Dmitriy, Dr
2015-12-01
Lloyd's Register Technical Investigation Department (LR TID) have developed numerical functions for the prediction of cavitation erosion aggressiveness within Computational Fluid Dynamics (CFD) simulations. These functions were previously validated for a model scale hydrofoil and ship scale rudder [1]. For the current study the functions were applied to a cargo ship's full scale propeller, on which the severe cavitation erosion was reported. The performed Detach Eddy Simulation (DES) required a fine computational mesh (approximately 22 million cells), together with a very small time step (2.0E-4 s). As the cavitation for this type of vessel is primarily caused by a highly non-uniform wake, the hull was also included in the simulation. The applied method under predicted the cavitation extent and did not fully resolve the tip vortex; however, the areas of cavitation collapse were captured successfully. Consequently, the developed functions showed a very good prediction of erosion areas, as confirmed by comparison with underwater propeller inspection results.
Examination of propeller sound production using large eddy simulation
NASA Astrophysics Data System (ADS)
Keller, Jacob; Kumar, Praveen; Mahesh, Krishnan
2018-06-01
The flow field of a five-bladed marine propeller operating at design condition, obtained using large eddy simulation, is used to calculate the resulting far-field sound. The results of three acoustic formulations are compared, and the effects of the underlying assumptions are quantified. The integral form of the Ffowcs-Williams and Hawkings (FW-H) equation is solved on the propeller surface, which is discretized into a collection of N radial strips. Further assumptions are made to reduce FW-H to a Curle acoustic analogy and a point-force dipole model. Results show that although the individual blades are strongly tonal in the rotor plane, the propeller is acoustically compact at low frequency and the tonal sound interferes destructively in the far field. The propeller is found to be acoustically compact for frequencies up to 100 times the rotation rate. The overall far-field acoustic signature is broadband. Locations of maximum sound of the propeller occur along the axis of rotation both up and downstream. The propeller hub is found to be a source of significant sound to observers in the rotor plane, due to flow separation and interaction with the blade-root wakes. The majority of the propeller sound is generated by localized unsteadiness at the blade tip, which is caused by shedding of the tip vortex. Tonal blade sound is found to be caused by the periodic motion of the loaded blades. Turbulence created in the blade boundary layer is convected past the blade trailing edge leading to generation of broadband noise along the blade. Acoustic energy is distributed among higher frequencies as local Reynolds number increases radially along the blades. Sound source correlation and spectra are examined in the context of noise modeling.
NASA advanced propeller research
NASA Technical Reports Server (NTRS)
Groeneweg, John F.; Bober, Lawrence J.
1988-01-01
Acoustic and aerodynamic research at NASA Lewis Research Center on advanced propellers is reviewed including analytical and experimental results on both single and counterrotation. Computational tools used to calculate the detailed flow and acoustic fields are described along with wind tunnel tests to obtain data for code verification. Results from two kinds of experiments are reviewed: (1) performance and near field noise at cruise conditions as measured in the NASA Lewis 8- by 6-foot Wind Tunnel; and (2) far field noise and performance for takeoff/approach conditions as measured in the NASA Lewis 9- by 15-foot Anechoic Wind Tunnel. Detailed measurements of steady blade surface pressures are described along with vortex flow phenomena at off-design conditions. Near field noise at cruise is shown to level out or decrease as tip relative Mach number is increased beyond 1.15. Counterrotation interaction noise is shown to be a dominant source at takeoff but a secondary source at cruise. Effects of unequal rotor diameters and rotor-to-rotor spacing on interaction noise are also illustrated. Comparisons of wind tunnel acoustic measurements to flight results are made. Finally, some future directions in advanced propeller research such as swirl recovery vanes, higher sweep, forward sweep, and ducted propellers are discussed.
The development of methods for predicting and measuring distribution patterns of aerial sprays
NASA Technical Reports Server (NTRS)
Ormsbee, A. I.; Bragg, M. B.; Maughmer, M. D.
1979-01-01
The capability of conducting scale model experiments which involve the ejection of small particles into the wake of an aircraft close to the ground is developed. A set of relationships used to scale small-sized dispersion studies to full-size results are experimentally verified and, with some qualifications, basic deposition patterns are presented. In the process of validating these scaling laws, the basic experimental techniques used in conducting such studies, both with and without an operational propeller, were developed. The procedures that evolved are outlined. The envelope of test conditions that can be accommodated in the Langley Vortex Research Facility, which were developed theoretically, are verified using a series of vortex trajectory experiments that help to define the limitations due to wall interference effects for models of different sizes.
NASA Astrophysics Data System (ADS)
Krappel, Timo; Riedelbauch, Stefan; Jester-Zuerker, Roland; Jung, Alexander; Flurl, Benedikt; Unger, Friedeman; Galpin, Paul
2016-11-01
The operation of Francis turbines in part load conditions causes high fluctuations and dynamic loads in the turbine and especially in the draft tube. At the hub of the runner outlet a rotating vortex rope within a low pressure zone arises and propagates into the draft tube cone. The investigated part load operating point is at about 72% discharge of best efficiency. To reduce the possible influence of boundary conditions on the solution, a flow simulation of a complete Francis turbine is conducted consisting of spiral case, stay and guide vanes, runner and draft tube. As the flow has a strong swirling component for the chosen operating point, it is very challenging to accurately predict the flow and in particular the flow losses in the diffusor. The goal of this study is to reach significantly better numerical prediction of this flow type. This is achieved by an improved resolution of small turbulent structures. Therefore, the Scale Adaptive Simulation SAS-SST turbulence model - a scale resolving turbulence model - is applied and compared to the widely used RANS-SST turbulence model. The largest mesh contains 300 million elements, which achieves LES-like resolution throughout much of the computational domain. The simulations are evaluated in terms of the hydraulic losses in the machine, evaluation of the velocity field, pressure oscillations in the draft tube and visual comparisons of turbulent flow structures. A pre-release version of ANSYS CFX 17.0 is used in this paper, as this CFD solver has a parallel performance up to several thousands of cores for this application which includes a transient rotor-stator interface to support the relative motion between the runner and the stationary portions of the water turbine.
NASA Technical Reports Server (NTRS)
Kendall, J. S.; Stoeffler, R. C.
1972-01-01
Investigations of various phases of gaseous nuclear rocket technology have been conducted. The principal research efforts have recently been directed toward the closed-cycle, vortex-stabilized nuclear light bulb engine and toward a small-scale fissioning uranium plasma experiment that could be conducted in the Los Alamos Scientific Laboratory's Nuclear Furnace. The engine concept is based on the transfer of energy by thermal radiation from gaseous fissioning uranium, through a transparent wall, to hydrogen propellant. The reference engine configuration is comprised of seven unit cavities, each having its own fuel transparent wall and propellant duct. The basic design of the engine is described. Subsequent studies performed to supplement and investigate the basic design are reported. Summaries of other nuclear light bulb research programs are included.
NASA Astrophysics Data System (ADS)
Jošt, D.; Škerlavaj, A.; Morgut, M.; Mežnar, P.; Nobile, E.
2015-01-01
The paper presents numerical simulations of flow in a model of a high head Francis turbine and comparison of results to the measurements. Numerical simulations were done by two CFD (Computational Fluid Dynamics) codes, Ansys CFX and OpenFOAM. Steady-state simulations were performed by k-epsilon and SST model, while for transient simulations the SAS SST ZLES model was used. With proper grid refinement in distributor and runner and with taking into account losses in labyrinth seals very accurate prediction of torque on the shaft, head and efficiency was obtained. Calculated axial and circumferential velocity components on two planes in the draft tube matched well with experimental results.
Broadband rotor noise analyses
NASA Technical Reports Server (NTRS)
George, A. R.; Chou, S. T.
1984-01-01
The various mechanisms which generate broadband noise on a range of rotors studied include load fluctuations due to inflow turbulence, due to turbulent boundary layers passing the blades' trailing edges, and due to tip vortex formation. Existing analyses are used and extensions to them are developed to make more accurate predictions of rotor noise spectra and to determine which mechanisms are important in which circumstances. Calculations based on the various prediction methods in existing experiments were compared. The present analyses are adequate to predict the spectra from a wide variety of experiments on fans, full scale and model scale helicopter rotors, wind turbines, and propellers to within about 5 to 10 dB. Better knowledge of the inflow turbulence improves the accuracy of the predictions. Results indicate that inflow turbulence noise depends strongly on ambient conditions and dominates at low frequencies. Trailing edge noise and tip vortex noise are important at higher frequencies if inflow turbulence is weak. Boundary layer trailing edge noise, important, for large sized rotors, increases slowly with angle of attack but not as rapidly as tip vortex noise.
Cavitation study of a pump-turbine at turbine mode with critical cavitation coefficient condition
NASA Astrophysics Data System (ADS)
Wang, J.; Yang, D.; Xu, J. W.; Liu, J. T.; Jiao, L.
2016-05-01
To study the cavitation phenomenon of a pump-turbine at turbine mode when it ran at the critical cavitation coefficient condition, a high-head model pump-turbine was disperse using hexahedron grid. Three dimensional, steady cavitating flow was numerically studied using SST k-ω model. It is confirmed that ZGB cavitation model and SST k-ω model are useful ways to study the two-phase cavitation flow in pump-turbine. Mass flow inlet and pressure outlet were specified at the casing inlet and draft tube outlet, respectively. The static pressure was set according to the cavitation coefficient. The steady cavitating flows at critical cavitation coefficient condition were analysed. The cavitation area in the runner was investigated. It was found that the pressure of the suction on the blade surface was decreasing gradually with the decrease of the cavitation coefficient. In addition, the vortex flow in the draft tube was observed at the critical cavitation coefficient. It was found that the vortex flow appeared at the center of the draft tube inlet with the decreasing of the cavitation coefficient. Compared with the experimental data, the simulation results show reasonable agreement with the experimental data.
A numerical simulation of the dispersal of aerial sprays
NASA Technical Reports Server (NTRS)
Bragg, M. B.
1981-01-01
A computer program was developed to predict the trajectory, ground deposition, and drift of liquid sprays injected into the wake of an agricultural aircraft in ground effect. The program uses a horseshoe vortex wake model and includes the effects of liquid droplet evaporation, crosswind, the propeller slipstream, ground effect, and tunnel walls on small scale models. This user's guide includes several case examples demonstrating user options. A complete listing of the FORTRAN program is provided.
NASA Advanced Propeller Research
NASA Technical Reports Server (NTRS)
Groeneweg, John F.; Bober, Lawrence J.
1988-01-01
Acoustic and aerodynamic research at NASA Lewis Research Center on advanced propellers is reviewed including analytical and experimental results on both single and counterrotation. Computational tools used to calculate the detailed flow and acoustic i e l d s a r e described along with wind tunnel tests to obtain data for code verification . Results from two kinds of experiments are reviewed: ( 1 ) performance and near field noise at cruise conditions as measured in the NASA Lewis 8-by 6-Foot Wind Tunnel and ( 2 ) farfield noise and performance for takeoff/approach conditions as measured in the NASA Lewis 9-by 15-Font Anechoic Wind Tunnel. Detailed measurements of steady blade surface pressures are described along with vortex flow phenomena at off design conditions . Near field noise at cruise is shown to level out or decrease as tip relative Mach number is increased beyond 1.15. Counterrotation interaction noise is shown to be a dominant source at take off but a secondary source at cruise. Effects of unequal rotor diameters and rotor-to-rotor spacing on interaction noise a real so illustrated. Comparisons of wind tunnel acoustic measurements to flight results are made. Finally, some future directions in advanced propeller research such as swirl recovery vanes, higher sweep, forward sweep, and ducted propellers are discussed.
Hydrodynamics of a three-dimensional self-propelled flexible plate
NASA Astrophysics Data System (ADS)
Ryu, Jaeha; Sung, Hyung Jin
2017-11-01
A three-dimensional self-propelled flexible plate in a quiescent flow was simulated using the immersed boundary method. The clamped leading edge of the flexible plate was forced into a vertical oscillation, while free to move horizontally. To reveal the hydrodynamics of the plate, the averaged cruising speed (UC) , the input power (P) , and the swimming efficiency (η) were analyzed as a function of the bending rigidity (γ) and the flapping frequency (f) . The velocity field around the plate and the exerted force on the plate were demonstrated to find out the dynamic interaction between the plate and the surrounding fluid. The kinematics of the plate, the maximum angle of attack (ϕmax) , and the mean effective length (Leff) were examined accounting for the hydrodynamics of the self-propelled flexible plate. The vortical structures around the plate were visualized, and the influence of the tip vortex on the swimming efficiency was explored qualitatively and quantitatively. This work was supported by the Creative Research Initiatives (No. 2017-013369) program of the National Research Foundation of Korea (MSIP).
Unsteady blade-surface pressures on a large-scale advanced propeller: Prediction and data
NASA Technical Reports Server (NTRS)
Nallasamy, M.; Groeneweg, J. F.
1990-01-01
An unsteady 3-D Euler analysis technique is employed to compute the flow field of an advanced propeller operating at an angle of attack. The predicted blade pressure waveforms are compared with wind tunnel data at two Mach numbers, 0.5 and 0.2. The inflow angle is three degrees. For an inflow Mach number of 0.5, the predicted pressure response is in fair agreement with data: the predicted phases of the waveforms are in close agreement with data while the magnitudes are underpredicted. At the low Mach number of 0.2 (takeoff), the numerical solution shows the formation of a leading edge vortex which is in qualitative agreement with measurements. However, the highly nonlinear pressure response measured on the blade suction surface is not captured in the present inviscid analysis.
Unsteady blade surface pressures on a large-scale advanced propeller - Prediction and data
NASA Technical Reports Server (NTRS)
Nallasamy, M.; Groeneweg, J. F.
1990-01-01
An unsteady three dimensional Euler analysis technique is employed to compute the flowfield of an advanced propeller operating at an angle of attack. The predicted blade pressure waveforms are compared with wind tunnel data at two Mach numbers, 0.5 and 0.2. The inflow angle is three degrees. For an inflow Mach number of 0.5, the predicted pressure response is in fair agreement with data: the predicted phases of the waveforms are in close agreement with data while the magnitudes are underpredicted. At the low Mach number of 0.2 (take-off) the numerical solution shows the formation of a leading edge vortex which is in qualitative agreement with measurements. However, the highly nonlinear pressure response measured on the blade suction surface is not captured in the present inviscid analysis.
Propulsion efficiency and imposed flow fields of a copepod jump.
Jiang, Houshuo; Kiørboe, Thomas
2011-02-01
Pelagic copepods jump to relocate, to attack prey and to escape predators. However, there is a price to be paid for these jumps in terms of their energy costs and the hydrodynamic signals they generate to rheotactic predators. Using observed kinematics of various types of jumps, we computed the imposed flow fields and associated energetics of jumps by means of computational fluid dynamics simulations by modeling the copepod as a self-propelled body. The computational fluid dynamics simulation was validated by particle image velocimetry data. The flow field generated by a repositioning jump quickly evolves into two counter-rotating viscous vortex rings that are near mirror image of one another, one in the wake and one around the body of the copepod; this near symmetrical flow may provide hydrodynamic camouflage because it contains no information about the position of the copepod prey within the flow structure. The flow field associated with an escape jump sequence also includes two dominant vortex structures: one leading wake vortex generated as a result of the first jump and one around the body, but between these two vortex structures is an elongated, long-lasting flow trail with flow velocity vectors pointing towards the copepod; such a flow field may inform the predator of the whereabouts of the escaping copepod prey. High Froude propulsion efficiency (0.94-0.98) was obtained for individual power stroke durations of all simulated jumps. This is unusual for small aquatic organisms but is caused by the rapidity and impulsiveness of the jump that allows only a low-cost viscous wake vortex to travel backwards.
Wing flapping with minimum energy. [minimize the drag for a bending moment at the wing root
NASA Technical Reports Server (NTRS)
Jones, R. T.
1980-01-01
For slow flapping motions it is found that the minimum energy loss occurs when the vortex wake moves as a rigid surface that rotates about the wing root - a condition analogous to that determined for a slow-turning propeller. The optimum circulation distribution determined by this condition differs from the elliptic distribution, showing a greater concentration of lift toward the tips. It appears that very high propulsive efficiencies are obtained by flapping.
Numerically-Based Ducted Propeller Design Using Vortex Lattice Lifting Line Theory
2008-01-01
greatly improved data visualization which includes graphic output and three-dimensional renderings. OpenProp was designed to perform two primary ...MATLAB® Code B.1 Q2half.m %Q2half: Legendre fuction of the second kind and positive half order %Ref: Handbook of Math Functions, Abramowitz and...134035, %Q2half(6)=.0382887, Q2half(8.4)=.0229646, Q2half(10)=.0176449 B.2 Q2Mhalf.m %Q2Mhalf: Legendre fuction of the second kind and minus half
Hydrodynamics of Peristaltic Propulsion
NASA Astrophysics Data System (ADS)
Athanassiadis, Athanasios; Hart, Douglas
2014-11-01
A curious class of animals called salps live in marine environments and self-propel by ejecting vortex rings much like jellyfish and squid. However, unlike other jetting creatures that siphon and eject water from one side of their body, salps produce vortex rings by pumping water through siphons on opposite ends of their hollow cylindrical bodies. In the simplest cases, it seems like some species of salp can successfully move by contracting just two siphons connected by an elastic body. When thought of as a chain of timed contractions, salp propulsion is reminiscent of peristaltic pumping applied to marine locomotion. Inspired by salps, we investigate the hydrodynamics of peristaltic propulsion, focusing on the scaling relationships that determine flow rate, thrust production, and energy usage in a model system. We discuss possible actuation methods for a model peristaltic vehicle, considering both the material and geometrical requirements for such a system.
NASA Astrophysics Data System (ADS)
Maines, Brant H.; Arndt, Roger E. A.
2000-11-01
Cavitation in vortical flows is a problem of practical importance, that is relatively unexplored. Vortical structures of importance range from the eddies occurring randomly in space and time in turbulent flows to the developed vortices that occur at the tips of lifting surfaces and at the hubs of propellers and hydraulic turbines. A variety of secondary flow phenomena such as the horse shoe vortices that form around bridge piers, chute blocks and struts, and the secondary vortices found in the clearance passages of turbomachinery are also important cavitation sites. Tip vortex cavitation can be viewed as a canonical problem that captures many of the essential physics associated with vortex cavitation in general. This paper describes the inception process and focuses on the high levels of tension that can be sustained in the flow, which appears to scale with the blade loading. High speed video visualization indicates that the details of how free stream nuclei are ingested plays a major role in the nucleation and inception process. A new photographic technique was used to obtain high quality images of the bubble growth process at framing rates as high as 40,000 fps. Sponsored by the Office of Naval Research
Quantitative flow analysis of swimming dynamics with coherent Lagrangian vortices.
Huhn, F; van Rees, W M; Gazzola, M; Rossinelli, D; Haller, G; Koumoutsakos, P
2015-08-01
Undulatory swimmers flex their bodies to displace water, and in turn, the flow feeds back into the dynamics of the swimmer. At moderate Reynolds number, the resulting flow structures are characterized by unsteady separation and alternating vortices in the wake. We use the flow field from simulations of a two-dimensional, incompressible viscous flow of an undulatory, self-propelled swimmer and detect the coherent Lagrangian vortices in the wake to dissect the driving momentum transfer mechanisms. The detected material vortex boundary encloses a Lagrangian control volume that serves to track back the vortex fluid and record its circulation and momentum history. We consider two swimming modes: the C-start escape and steady anguilliform swimming. The backward advection of the coherent Lagrangian vortices elucidates the geometry of the vorticity field and allows for monitoring the gain and decay of circulation and momentum transfer in the flow field. For steady swimming, momentum oscillations of the fish can largely be attributed to the momentum exchange with the vortex fluid. For the C-start, an additionally defined jet fluid region turns out to balance the high momentum change of the fish during the rapid start.
Computation of Cavitating Flow in a Francis Hydroturbine
NASA Astrophysics Data System (ADS)
Leonard, Daniel; Lindau, Jay
2013-11-01
In an effort to improve cavitation characteristics at off-design conditions, a steady, periodic, multiphase, RANS CFD study of an actual Francis hydroturbine was conducted and compared to experimental results. It is well-known that operating hydroturbines at off-design conditions usually results in the formation of large-scale vaporous cavities. These cavities, and their subsequent collapse, reduce efficiency and cause damage and wear to surfaces. The conventional hydro community has expressed interest in increasing their turbine's operating ranges, improving their efficiencies, and reducing damage and wear to critical turbine components. In this work, mixing planes were used to couple rotating and stationary stages of the turbine which have non-multiple periodicity, and provide a coupled solution for the stay vanes, wicket gates, runner blades, and draft tube. The mixture approach is used to simulate the multiphase flow dynamics, and cavitation models were employed to govern the mass transfer between liquid and gas phases. The solution is compared with experimental results across a range of cavitation numbers which display all the major cavitation features in the machine. Unsteady computations are necessary to capture inherently unsteady cavitation phenomena, such as the precessing vortex rope, and the shedding of bubbles from the wicket gates and their subsequent impingement upon the leading edge of the runner blades. To display these features, preliminary unsteady simulations of the full machine are also presented.
A physics based multiscale modeling of cavitating flows.
Ma, Jingsen; Hsiao, Chao-Tsung; Chahine, Georges L
2017-03-02
Numerical modeling of cavitating bubbly flows is challenging due to the wide range of characteristic lengths of the physics at play: from micrometers (e.g., bubble nuclei radius) to meters (e.g., propeller diameter or sheet cavity length). To address this, we present here a multiscale approach which integrates a Discrete Singularities Model (DSM) for dispersed microbubbles and a two-phase Navier Stokes solver for the bubbly medium, which includes a level set approach to describe large cavities or gaseous pockets. Inter-scale schemes are used to smoothly bridge the two transitioning subgrid DSM bubbles into larger discretized cavities. This approach is demonstrated on several problems including cavitation inception and vapor core formation in a vortex flow, sheet-to-cloud cavitation over a hydrofoil, cavitation behind a blunt body, and cavitation on a propeller. These examples highlight the capabilities of the developed multiscale model in simulating various form of cavitation.
Ground effect on a self-propelled undulatory foil
NASA Astrophysics Data System (ADS)
Zhang, Dong; Chao, Liming; Pan, Guang
2018-04-01
The unsteady ground effect on a self-propelled undulatory foil is numerically investigated in this paper. The situation can be widely found in nature especially for fish swimming near the ground. In this study, frequency varies from 0.1 Hz to 2 Hz and distance from the ground varies from 0.2 L to 1 L. Under most kinematics, the ground has a negative effect on the performance of the foil. The swimming velocity slows down, power spend increases and swimming economy reduces. The higher frequency can produce a larger negative effect. Only at the low frequencies f = 0.1 Hz, 0.25 Hz and 0.5 Hz with distance of 0.2 L the velocity can be enhanced by 18%, 6%, 0.8%, respectively. The lift production is found to be increased. The link between the performance and the wake dynamics is also established by studying the vortex structures.
A physics based multiscale modeling of cavitating flows
Ma, Jingsen; Hsiao, Chao-Tsung; Chahine, Georges L.
2018-01-01
Numerical modeling of cavitating bubbly flows is challenging due to the wide range of characteristic lengths of the physics at play: from micrometers (e.g., bubble nuclei radius) to meters (e.g., propeller diameter or sheet cavity length). To address this, we present here a multiscale approach which integrates a Discrete Singularities Model (DSM) for dispersed microbubbles and a two-phase Navier Stokes solver for the bubbly medium, which includes a level set approach to describe large cavities or gaseous pockets. Inter-scale schemes are used to smoothly bridge the two transitioning subgrid DSM bubbles into larger discretized cavities. This approach is demonstrated on several problems including cavitation inception and vapor core formation in a vortex flow, sheet-to-cloud cavitation over a hydrofoil, cavitation behind a blunt body, and cavitation on a propeller. These examples highlight the capabilities of the developed multiscale model in simulating various form of cavitation. PMID:29720773
Unsteady blade pressure measurements for the SR-7A propeller at cruise conditions
NASA Technical Reports Server (NTRS)
Heidelberg, L. J.; Nallasamy, M.
1990-01-01
The unsteady blade surface pressures were measured on the SR-7A propeller. The freestream Mach no., inflow angle, and advance ratio were varied while measurements were made at nine blade stations. At a freestream Mach no. of 0.8, the data in terms of unsteady pressure coefficient vs. azimuth angle are compared to an unsteady 3-D Euler solution, yielding very encouraging results. The code predicts the shape (phase) of the waveform very well, while the magnitude is over-predicted in many cases. At tunnel Mach nos. below 0.6, an unusually large response on the suction surface at 0.15 chord and 0.88 radius was observed. The behavior of this response suggests the presence of a leading edge vortex. The midchord measuring stations on the suction surface exhibit a response that leads the forcing function while most other locations show a phase lag.
Injection and swirl driven flowfields in solid and liquid rocket motors
NASA Astrophysics Data System (ADS)
Vyas, Anand B.
In this work, we seek approximate analytical solutions to describe the bulk flow motion in certain types of solid and liquid rocket motors. In the case of an idealized solid rocket motor, a cylindrical double base propellant grain with steady regression rate is considered. The well known inviscid profile determined by Culick is extended here to include the effects of viscosity and steady grain regression. The approximate analytical solution for the cold flow is obtained from similarity principles, perturbation methods and the method of variation of parameters. The velocity, vorticity, pressure gradient and the shear stress distributions are determined and interpreted for different rates of wall regression and injection Reynolds number. The liquid propellant rocket engine considered here is based on a novel design that gives rise to a cyclonic flow. The resulting bidirectional motion is triggered by the tangential injection of an oxidizer just upstream of the chamber nozzle. Velocity, vorticity and pressure gradient distributions are determined for the bulk gas dynamics using a non-reactive inviscid model. Viscous corrections are then incorporated to explain the formation of a forced vortex near the core. Our results compare favorably with numerical simulations and experimental measurements obtained by other researchers. They also indicate that the bidirectional vortex in a cylindrical chamber is a physical solution of the Euler equations. In closing, we investigate the possibility of multi-directional flow behavior as predicted by Euler's equation and as reported recently in laboratory experiments.
Wen, L; Wang, T M; Wu, G H; Liang, J H
2012-09-01
We implement a mackerel (Scomber scombrus) body-shaped robot, programmed to display the three most typical body/caudal fin undulatory kinematics (i.e. anguilliform, carangiform and thunniform), in order to biomimetically investigate hydrodynamic issues not easily tackled experimentally with live fish. The robotic mackerel, mounted on a servo towing system and initially at rest, can determine its self-propelled speed by measuring the external force acting upon it and allowing for the simultaneous measurement of power, flow field and self-propelled speed. Experimental results showed that the robotic swimmer with thunniform kinematics achieved a faster final swimming speed (St = 0.424) relative to those with carangiform (St = 0.43) and anguilliform kinematics (St = 0.55). The thrust efficiency, estimated from a digital particle image velocimetry (DPIV) flow field, showed that the robotic swimmer with thunniform kinematics is more efficient (47.3%) than those with carangiform (31.4%) and anguilliform kinematics (26.6%). Furthermore, the DPIV measurements illustrate that the large-scale characteristics of the flow pattern generated by the robotic swimmer with both anguilliform and carangiform kinematics were wedge-like, double-row wake structures. Additionally, a typical single-row reverse Karman vortex was produced by the robotic swimmer using thunniform kinematics. Finally, we discuss this novel force-feedback-controlled experimental method, and review the relative self-propelled hydrodynamic results of the robot when utilizing the three types of undulatory kinematics.
Runaway transient simulation of a model Kaplan turbine
NASA Astrophysics Data System (ADS)
Liu, S.; Zhou, D.; Liu, D.; Wu, Y.; Nishi, M.
2010-08-01
The runaway transient is a typical transient process of a hydro power unit, where the rotational speed of a turbine runner rapidly increases up to the runaway speed under a working head as the guide vanes cannot be closed due to some reason at the load rejection. In the present paper, the characteristics of the runaway transient of a model Kaplan turbine having ns = 479(m-kW) is simulated by using a time-dependent CFD technique where equation of rotational motion of runner, continuity equation and unsteady RANS equations with RNG k-epsilon turbulence model are solved iteratively. In the calculation, unstructured mesh is used to the whole flow passage, which consists of several sub-domains: entrance, casing, stay vanes + guide vanes, guide section, runner and draft tube. And variable speed sliding mesh technique is used to exchange interface flow information between moving part and stationary part, and three-dimensional unstructured dynamic mesh technique is also adopted to ensure mesh quality. Two cases were treated in the simulation of runaway transient characteristics after load rejection: one is the rated operating condition as the initial condition, and the other is the condition at the maximum head. Regarding the runaway speed, the experimental speed is 1.45 times the initial speed and the calculation is 1.47 times the initial for the former case. In the latter case, the experiment and the calculation are 1.67 times and 1.69 times respectively. From these results, it is recognized that satisfactorily prediction will be possible by using the present numerical method. Further, numerical results show that the swirl in the draft-tube flow becomes stronger in the latter part of the transient process so that a vortex rope will occur in the draft tube and its precession will cause the pressure fluctuations which sometimes affect the stability of hydro power system considerably.
Performance of a low-power subsonic-arc-attachment arcjet thruster
NASA Technical Reports Server (NTRS)
Sankovic, John M.; Berns, Darren H.
1993-01-01
A subsonic-arc-attachment thruster design was scaled from a 30 kW 1960's vintage thruster to operate at nominally 3 kW. Performance measurements were obtained over a 1-4 kW power range using hydrogen as the propellant. Several modes of operation were identified and were characterized by varying degrees of voltage instability. A stability map was developed showing that the voltage oscillations were brought upon by elevated current or propellant levels. At a given specific energy level the specific impulse increased asymptotically with increased flow rates. Comparisons of performance were made between radial and tangential propellant injection. When the vortex flow was eliminated using radial injection, the operating voltages were lower at a given current, and the specific impulse and efficiency decreased. Tests were also conducted to determine the effects of background pressure on operation, and performance data were obtained at pressures of 0.047 Pa and 18 Pa. For a given specific energy level, the performance increased with a decrease in facility background pressure. Lowering the background pressure also caused a dramatic change in the voltage-current characteristic and the voltage stability, a phenomenon not previously reported with conventional supersonic-arc-attachment thrusters.
Effect of chemical heat release in a temporally evolving mixing layer
NASA Technical Reports Server (NTRS)
Higuera, F. J.; Moser, R. D.
1994-01-01
Two-dimensional numerical simulations of a temporally evolving mixing layer with an exothermic infinitely fast diffusion flame between two unmixed reactants have been carried out in the limit of zero Mach number to study the effect of the heat release on the early stages of the evolution of the flow. Attention has been directed to relatively large values of the oxidizer-to-fuel mass stoichiometric ratio typical of hydrocarbon flames, and initial vorticity distributions thicker than the temperature and species distributions have been chosen to mimic the situation at the outlet of a jet. The results show that, during the stages of the evolution covered by the present simulations, enhancement of combustion occurs by local stretching of the flame without much augmentation of its area. The rate of product generation depends strongly on the initial conditions, which suggests the possibility of controlling the combustion by acting on the flow. Rollup and vortex amalgamation still occur in these reacting flows but are very much affected by the production of new vorticity by baroclinic torques. These torques lead to counter rotating vortex pairs around the flame and, more importantly, in thin layers of light fluid that leave the vicinity of the flame when the Kelvin-Helmholtz instability begins to develop. Propelled by the vortex pairs, these layers wind around, split on reaching high pressure regions, and originate new vortex pairs in a process that ends up building large-scale vortices with a vorticity distribution more complex than for a constant density fluid.
NASA Astrophysics Data System (ADS)
Roger, Michel; Schram, Christophe; Moreau, Stéphane
2014-01-01
A linear analytical model is developed for the chopping of a cylindrical vortex by a flat-plate airfoil, with or without a span-end effect. The major interest is the contribution of the tip-vortex produced by an upstream rotating blade in the rotor-rotor interaction noise mechanism of counter-rotating open rotors. Therefore the interaction is primarily addressed in an annular strip of limited spanwise extent bounding the impinged blade segment, and the unwrapped strip is described in Cartesian coordinates. The study also addresses the interaction of a propeller wake with a downstream wing or empennage. Cylindrical vortices are considered, for which the velocity field is expanded in two-dimensional gusts in the reference frame of the airfoil. For each gust the response of the airfoil is derived, first ignoring the effect of the span end, assimilating the airfoil to a rigid flat plate, with or without sweep. The corresponding unsteady lift acts as a distribution of acoustic dipoles, and the radiated sound is obtained from a radiation integral over the actual extent of the airfoil. In the case of tip-vortex interaction noise in CRORs the acoustic signature is determined for vortex trajectories passing beyond, exactly at and below the tip radius of the impinged blade segment, in a reference frame attached to the segment. In a second step the same problem is readdressed accounting for the effect of span end on the aerodynamic response of a blade tip. This is achieved through a composite two-directional Schwarzschild's technique. The modifications of the distributed unsteady lift and of the radiated sound are discussed. The chained source and radiation models provide physical insight into the mechanism of vortex chopping by a blade tip in free field. They allow assessing the acoustic benefit of clipping the rear rotor in a counter-rotating open-rotor architecture.
NASA Technical Reports Server (NTRS)
Haefner, K. B.; Honda, T. S.
1973-01-01
A fluidic emergency roll control system for aircraft stabilization in the event of primary flight control failure was evaluated. The fluidic roll control units were designed to provide roll torque proportional to an electrical command as operated by two diametrically opposed thrust nozzles located in the wing tips. The control package consists of a solid propellant gas generator, two diametrically opposed vortex valve modulated thrust nozzles, and an electromagnetic torque motor. The procedures for the design, development, and performance testing of the system are described.
Gas Dynamics of a Recessed Nozzle in Its Displacement in the Radial Direction
NASA Astrophysics Data System (ADS)
Volkov, K. N.; Denisikhin, S. V.; Emel'yanov, V. N.
2017-07-01
Numerical simulation of gasdynamic processes accompanying the operation of the recessed nozzle of a solid-propellant rocket motor in its linear displacement is carried out. Reynolds-averaged Navier-Stokes equations closed using the equations of a k-ɛ turbulence model are used for calculations. The calculations are done for different rates of flow of the gas in the main channel and in the over-nozzle gap, and also for different displacements of the nozzle from an axisymmetric position. The asymmetry of geometry gives rise to a complicated spatial flow pattern characterized by the presence of singular points of spreading and by substantially inhomogeneous velocity and pressure distributions. The vortex flow pattern resulting from the linear displacement of the nozzle from an axisymmetric position is compared with the data of experimental visualization. The change in the vortex pattern of the flow and in the position of the singular points as a function of the flow coefficient and the displacement of the nozzle from the symmetry axis is discussed.
Effects of independently altering body weight and body mass on the metabolic cost of running.
Teunissen, Lennart P J; Grabowski, Alena; Kram, Rodger
2007-12-01
The metabolic cost of running is substantial, despite the savings from elastic energy storage and return. Previous studies suggest that generating vertical force to support body weight and horizontal forces to brake and propel body mass are the major determinants of the metabolic cost of running. In the present study, we investigated how independently altering body weight and body mass affects the metabolic cost of running. Based on previous studies, we hypothesized that reducing body weight would decrease metabolic rate proportionally, and adding mass and weight would increase metabolic rate proportionally. Further, because previous studies show that adding mass alone does not affect the forces generated on the ground, we hypothesized that adding mass alone would have no substantial effect on metabolic rate. We manipulated the body weight and body mass of 10 recreational human runners and measured their metabolic rates while they ran at 3 m s(-1). We reduced weight using a harness system, increased mass and weight using lead worn about the waist, and increased mass alone using a combination of weight support and added load. We found that net metabolic rate decreased in less than direct proportion to reduced body weight, increased in slightly more than direct proportion to added load (added mass and weight), and was not substantially different from normal running with added mass alone. Adding mass alone was not an effective method for determining the metabolic cost attributable to braking/propelling body mass. Runners loaded with mass alone did not generate greater vertical or horizontal impulses and their metabolic costs did not substantially differ from those of normal running. Our results show that generating force to support body weight is the primary determinant of the metabolic cost of running. Extrapolating our reduced weight data to zero weight suggests that supporting body weight comprises at most 74% of the net cost of running. However, 74% is probably an overestimate of the metabolic demand of body weight to support itself because in reduced gravity conditions decrements in horizontal impulse accompanied decrements in vertical impulse.
The fish tail motion forms an attached leading edge vortex
Borazjani, Iman; Daghooghi, Mohsen
2013-01-01
The tail (caudal fin) is one of the most prominent characteristics of fishes, and the analysis of the flow pattern it creates is fundamental to understanding how its motion generates locomotor forces. A mechanism that is known to greatly enhance locomotor forces in insect and bird flight is the leading edge vortex (LEV) reattachment, i.e. a vortex (separation bubble) that stays attached at the leading edge of a wing. However, this mechanism has not been reported in fish-like swimming probably owing to the overemphasis on the trailing wake, and the fact that the flow does not separate along the body of undulating swimmers. We provide, to our knowledge, the first evidence of the vortex reattachment at the leading edge of the fish tail using three-dimensional high-resolution numerical simulations of self-propelled virtual swimmers with different tail shapes. We show that at Strouhal numbers (a measure of lateral velocity to the axial velocity) at which most fish swim in nature (approx. 0.25) an attached LEV is formed, whereas at a higher Strouhal number of approximately 0.6 the LEV does not reattach. We show that the evolution of the LEV drastically alters the pressure distribution on the tail and the force it generates. We also show that the tail's delta shape is not necessary for the LEV reattachment and fish-like kinematics is capable of stabilising the LEV. Our results suggest the need for a paradigm shift in fish-like swimming research to turn the focus from the trailing edge to the leading edge of the tail. PMID:23407826
Passive propulsion in vortex wakes
NASA Astrophysics Data System (ADS)
Beal, D. N.; Hover, F. S.; Triantafyllou, M. S.; Liao, J. C.; Lauder, G. V.
A dead fish is propelled upstream when its flexible body resonates with oncoming vortices formed in the wake of a bluff cylinder, despite being well outside the suction region of the cylinder. Within this passive propulsion mode, the body of the fish extracts sufficient energy from the oncoming vortices to develop thrust to overcome its own drag. In a similar turbulent wake and at roughly the same distance behind a bluff cylinder, a passively mounted high-aspect-ratio foil is also shown to propel itself upstream employing a similar flow energy extraction mechanism. In this case, mechanical energy is extracted from the flow at the same time that thrust is produced. These results prove experimentally that, under proper conditions, a body can follow at a distance or even catch up to another upstream body without expending any energy of its own. This observation is also significant in the development of low-drag energy harvesting devices, and in the energetics of fish dwelling in flowing water and swimming behind wake-forming obstacles.
Laser velocimeter measurements of the flowfield generated by an advanced counterrotating propeller
NASA Technical Reports Server (NTRS)
Podboy, Gary G.; Krupar, Martin J.
1989-01-01
Results are presented of an investigation to measure the flowfield generated by an advanced counterrotating pusher propeller model similar to the full-scale Unducted Fan demonstrator engine. A laser Doppler velocimeter was used to measure the velocity field in several planes normal to the centerline of the model at axial stations upstream and downstream of each rotor. During this investigation, blades of the F4/A4 type were installed on the model which was operating in a freestream Mach 0.72 regime, with the advance ratio of each rotor set at 2.80. The measured data indicate only a slight influence of the potential field of each front rotor blade on the flowfield upstream of the rotor. The data measured downstream of the front rotor characterize the tip vortices, vortex sheets and potential field nonuniformities generated by the front rotor. The unsteadiness of the flow in the rotating frame of reference of the aft rotor is also illustrated.
Design and Performance of the NASA SCEPTOR Distributed Electric Propulsion Flight Demonstrator
NASA Technical Reports Server (NTRS)
Borer, Nicholas K.; Patterson, Michael D.; Viken, Jeffrey K.; Moore, Mark D.; Clarke, Sean; Redifer, Matthew E.; Christie, Robert J.; Stoll, Alex M.; Dubois, Arthur; Bevirt, JoeBen;
2016-01-01
Distributed Electric Propulsion (DEP) technology uses multiple propulsors driven by electric motors distributed about the airframe to yield beneficial aerodynamic-propulsion interaction. The NASA SCEPTOR flight demonstration project will retrofit an existing internal combustion engine-powered light aircraft with two types of DEP: small "high-lift" propellers distributed along the leading edge of the wing which accelerate the flow over the wing at low speeds, and larger cruise propellers co-located with each wingtip for primary propulsive power. The updated high-lift system enables a 2.5x reduction in wing area as compared to the original aircraft, reducing drag at cruise and shifting the velocity for maximum lift-to-drag ratio to a higher speed, while maintaining low-speed performance. The wingtip-mounted cruise propellers interact with the wingtip vortex, enabling a further efficiency increase that can reduce propulsive power by 10%. A tradespace exploration approach is developed that enables rapid identification of salient trades, and subsequent creation of SCEPTOR demonstrator geometries. These candidates were scrutinized by subject matter experts to identify design preferences that were not modeled during configuration exploration. This exploration and design approach is used to create an aircraft that consumes an estimated 4.8x less energy at the selected cruise point when compared to the original aircraft.
Bredeweg, S W; Buist, I; Kluitenberg, B
2013-09-01
The purpose of this prospective study was to describe natural levels of asymmetry in running, compare levels of asymmetry between injured and noninjured novice runners and compare kinetic variables between the injured and noninjured lower limb within the novice runners with an injury. At baseline vertical ground reaction forces and symmetry angles (SA) were assessed with an instrumented treadmill equipped with three force measuring transducers. Female participants ran at 8 and 9 km h(-1) and male runners ran at 9 and 10 km h(-1). Participants were novice female and male recreational runners and were followed during a 9-week running program. Two hundred and ten novice runners enrolled this study, 133 (63.3%) female and 77 (36.7%) male runners. Thirty-four runners reported an RRI. At baseline SA values varied widely for all spatio-temporal and kinetic variables. The inter-individual differences in SA were also high. No significant differences in SA were found between female and male runners running at 9 km h(-1). In injured runners the SA of the impact peak was significantly lower compared to noninjured runners. Natural levels of asymmetry in running were high. The SA of impact peak in injured runners was lower compared to noninjured runners and no differences were seen between the injured and noninjured lower limbs. Copyright © 2013 Elsevier B.V. All rights reserved.
Biomechanical variables associated with Achilles tendinopathy in runners.
Azevedo, L B; Lambert, M I; Vaughan, C L; O'Connor, C M; Schwellnus, M P
2009-04-01
The aim of this study was to investigate the kinetics, kinematics and muscle activity in runners with Achilles tendinopathy. Case-control study. Biomechanics laboratory. 21 runners free from injury and 21 runners with Achilles tendinopathy performed 10 running trials with standardised running shoes. Injured runners were diagnosed clinically according to established diagnostic criteria. Uninjured runners had been injury-free for at least 2 years. During each trial, kinetic and lower limb kinematic data were measured using a strain gauge force plate and six infrared cameras respectively. Electromyographic (EMG) data from six muscles (tibialis anterior (TA), peroneus longus (PE), lateral gastrocnemius (LG), rectus femoris (RF), biceps femoris (BF) and gluteus medius (GM)) were measured with a telemetric EMG system. Knee range of motion (heel strike to midstance) was significantly lower in injured runners than in uninjured runners. Similarly, preactivation (integrated EMG (IEMG) in 100 ms before heel strike) of TA was lower for injured runners than uninjured runners. RF and GM IEMG activity 100 ms after heel strike was also lower in the injured group. However, impact forces were not different between the two groups. Altered knee kinematics and reduced muscle activity are associated with Achilles tendinopathy in runners. Rehabilitation exercises or other mechanisms (e.g. footwear) that affect kinematics and muscle activity may therefore be beneficial in the treatment of runners with Achilles tendinopathy.
Numerical Simulation of the Francis Turbine and CAD used to Optimized the Runner Design (2nd).
NASA Astrophysics Data System (ADS)
Sutikno, Priyono
2010-06-01
Hydro Power is the most important renewable energy source on earth. The water is free of charge and with the generation of electric energy in a Hydroelectric Power station the production of green house gases (mainly CO2) is negligible. Hydro Power Generation Stations are long term installations and can be used for 50 years and more, care must be taken to guarantee a smooth and safe operation over the years. Maintenance is necessary and critical parts of the machines have to be replaced if necessary. Within modern engineering the numerical flow simulation plays an important role in order to optimize the hydraulic turbine in conjunction with connected components of the plant. Especially for rehabilitation and upgrading existing Power Plants important point of concern are to predict the power output of turbine, to achieve maximum hydraulic efficiency, to avoid or to minimize cavitations, to avoid or to minimized vibrations in whole range operation. Flow simulation can help to solve operational problems and to optimize the turbo machinery for hydro electric generating stations or their component through, intuitive optimization, mathematical optimization, parametric design, the reduction of cavitations through design, prediction of draft tube vortex, trouble shooting by using the simulation. The classic design through graphic-analytical method is cumbersome and can't give in evidence the positive or negative aspects of the designing options. So it was obvious to have imposed as necessity the classical design methods to an adequate design method using the CAD software. There are many option chose during design calculus in a specific step of designing may be verified in ensemble and detail form a point of view. The final graphic post processing would be realized only for the optimal solution, through a 3 D representation of the runner as a whole for the final approval geometric shape. In this article it was investigated the redesign of the hydraulic turbine's runner, medium head Francis type, with following value for the most important parameter, the rated specific speed ns.
NASA Astrophysics Data System (ADS)
Sedwick, Raymond John
1998-12-01
A novel method for containing gaseous uranium vapor in an open cycle nuclear space propulsion system is developed. In an attempt to increase the operating temperature of the nuclear reactor beyond the melting point of solid fuel rods (thus increasing specific impulse), the fuel is instead suspended as a vapor in the propellant using the pressure forces developed in a confined vortex flow. The introduction of the fuel as uranium hexafluoride is found to be effective in maintaining its vapor phase in the feed passages from the tank, but not in the main vortex. A mechanism by which the resulting condensation of the uranium may be tolerated is identified, and the electro- optical properties of the resulting mixture are investigated. Containment is modeled using a 1D- axisymmetric geometry, and radiative heat transfer is found to restrict the maximum specific impulse of the system to 1500 seconds using pumping pressures of 500 atm. The specific impulse is related to this pressure as pm1/4, allowing only marginal increases in Isp at increased pressure levels. Additional 2D- axisymmetric issues, such as non-uniform current distribution and bypass flows through the boundary layers, are investigated, with possible methods of solution cited. A two-group, two-region reactor analysis is performed, estimating the mass of the reactor to be about 10 metric tonnes, and establishing the thrust to weight ratio achievable by the system at about 50. To reduce the mass of the power system, a scheme for using cross-flow heat exchange with the propellant flow to minimize (and possibly eliminate) the need for radiators to reject waste heat is presented. (Copies available exclusively from MIT Libraries, Rm. 14-0551, Cambridge, MA 02139-4307. Ph. 617-253-5668; Fax 617-253-1690.)
Differences in Muscle Activity between Natural Forefoot and Rearfoot Strikers during Running
Yong, Jennifer R.; Silder, Amy; Delp, Scott L.
2014-01-01
Running research has focused on reducing injuries by changing running technique. One proposed method is to change from rearfoot striking (RFS) to forefoot striking (FFS) because FFS is thought to be a more natural running pattern that may reduce loading and injury risk. Muscle activity affects loading and influences running patterns; however, the differences in muscle activity between natural FFS runners and natural RFS runners are unknown. The purpose of this study was to measure muscle activity in natural FFS runners and natural RFS runners. We tested the hypotheses that tibialis anterior activity would be significantly lower while activity of the plantarflexors would be significantly greater in FFS runners, compared to RFS runners, during late swing phase and early stance phase. Gait kinematics, ground reaction forces and electromyographic patterns of ten muscles were collected from twelve natural RFS runners and ten natural FFS runners. The root mean square (RMS) of each muscle’s activity was calculated during terminal swing phase and early stance phase. We found significantly lower RMS activity in the tibialis anterior in FFS runners during terminal swing phase, compared to RFS runners. In contrast, the medial and lateral gastrocnemius showed significantly greater RMS activity in terminal swing phase in FFS runners. No significant differences were found during early stance phase for the tibialis anterior or the plantarflexors. Recognizing the differences in muscle activity between FFS and RFS runners is an important step toward understanding how foot strike patterns may contribute to different types of injury. PMID:25458201
Modelling of a Francis Turbine Runner Fatigue Failure Process Caused by Fluid-Structure Interaction
NASA Astrophysics Data System (ADS)
Lyutov, A.; Kryukov, A.; Cherny, S.; Chirkov, D.; Salienko, A.; Skorospelov, V.; Turuk, P.
2016-11-01
In the present paper considered is the problem of the numerical simulation of Francis turbine runner fatigue failure caused by fluid-structure interaction. The unsteady 3D flow is modeled simultaneously in the spiral chamber, each wicket gate and runner channels and in the draft tube using the Euler equations. Based on the unsteady runner loadings at each time step stresses in the whole runner are calculated using the elastic equilibrium equations solved with boundary element method. Set of static stress-strain states provides quasi-dynamics of runner cyclic loading. It is assumed that equivalent stresses in the runner are below the critical value after which irreversible plastic processes happen in the runner material. Therefore runner is subjected to the fatigue damage caused by high-cycle fatigue, in which the loads are generally low compared with the limit stress of the material. As a consequence, the stress state around the crack front can be fully characterized by linear elastic fracture mechanics. The place of runner cracking is determined as a point with maximal amplitude of stress oscillations. Stress pulsations amplitude is used to estimate the number of cycles until the moment of fatigue failure, number of loading cycles and oscillation frequency are used to calculate runner service time. Example of the real Francis runner which has encountered premature fatigue failure as a result of incorrect durability estimation is used to verify the developed numerical model.
Older Runners Retain Youthful Running Economy despite Biomechanical Differences.
Beck, Owen N; Kipp, Shalaya; Roby, Jaclyn M; Grabowski, Alena M; Kram, Rodger; Ortega, Justus D
2016-04-01
Sixty-five years of age typically marks the onset of impaired walking economy. However, running economy has not been assessed beyond the age of 65 yr. Furthermore, a critical determinant of running economy is the spring-like storage and return of elastic energy from the leg during stance, which is related to leg stiffness. Therefore, we investigated whether runners older than 65 yr retain youthful running economy and/or leg stiffness across running speeds. Fifteen young and 15 older runners ran on a force-instrumented treadmill at 2.01, 2.46, and 2.91 m·s(-1). We measured their rates of metabolic energy consumption (i.e., metabolic power), ground reaction forces, and stride kinematics. There were only small differences in running economy between young and older runners across the range of speeds. Statistically, the older runners consumed 2% to 9% less metabolic energy than the young runners across speeds (P = 0.012). Also, the leg stiffness of older runners was 10% to 20% lower than that of young runners across the range of speeds (P = 0.002), and in contrast to the younger runners, the leg stiffness of older runners decreased with speed (P < 0.001). Runners beyond 65 yr of age maintain youthful running economy despite biomechanical differences. It may be that vigorous exercise, such as running, prevents the age related deterioration of muscular efficiency and, therefore, may make everyday activities easier.
A Design Tool for Liquid Rocket Engine Injectors
NASA Technical Reports Server (NTRS)
Farmer, R.; Cheng, G.; Trinh, H.; Tucker, K.
2000-01-01
A practical design tool which emphasizes the analysis of flowfields near the injector face of liquid rocket engines has been developed and used to simulate preliminary configurations of NASA's Fastrac and vortex engines. This computational design tool is sufficiently detailed to predict the interactive effects of injector element impingement angles and points and the momenta of the individual orifice flows and the combusting flow which results. In order to simulate a significant number of individual orifices, a homogeneous computational fluid dynamics model was developed. To describe sub- and supercritical liquid and vapor flows, the model utilized thermal and caloric equations of state which were valid over a wide range of pressures and temperatures. The model was constructed such that the local quality of the flow was determined directly. Since both the Fastrac and vortex engines utilize RP-1/LOX propellants, a simplified hydrocarbon combustion model was devised in order to accomplish three-dimensional, multiphase flow simulations. Such a model does not identify drops or their distribution, but it does allow the recirculating flow along the injector face and into the acoustic cavity and the film coolant flow to be accurately predicted.
The effect of bottom friction on tidal dipolar vortices and the associated transport
NASA Astrophysics Data System (ADS)
Duran-Matute, Matias; Kamp, Leon; van Heijst, Gertjan
2016-11-01
Tidal dipolar vortices can be formed in a semi-enclosed basin as the tides flow in and out through an inlet. If they are strong enough to overcome the opposing tidal currents, these vortices can travel away from the inlet due to their self-propelling mechanism, and hence, act as an efficient transport agent for suspended material. We present results of two-dimensional numerical simulations of the flow through an idealized tidal inlet, with either a linear or a nonlinear parameterization of the bottom friction. We then quantify the effect of the bottom friction on the propagation of the dipolar vortex and on its ability as a transport agent by computing the flushing and residence times of passive particles. Bottom friction is detrimental to the ability of tidal dipolar vortices to propagate and hinders transport away from the inlet. The magnitude of this effect is related to the relative duration of the tidal period as compared to the typical decay time scale of the vortex dipole. This research is funded by NWO (the Netherlands) through the VENI Grant 863.13.022.
Differences in muscle activity between natural forefoot and rearfoot strikers during running.
Yong, Jennifer R; Silder, Amy; Delp, Scott L
2014-11-28
Running research has focused on reducing injuries by changing running technique. One proposed method is to change from rearfoot striking (RFS) to forefoot striking (FFS) because FFS is thought to be a more natural running pattern that may reduce loading and injury risk. Muscle activity affects loading and influences running patterns; however, the differences in muscle activity between natural FFS runners and natural RFS runners are unknown. The purpose of this study was to measure muscle activity in natural FFS runners and natural RFS runners. We tested the hypotheses that tibialis anterior activity would be significantly lower while activity of the plantarflexors would be significantly greater in FFS runners, compared to RFS runners, during late swing phase and early stance phase. Gait kinematics, ground reaction forces and electromyographic patterns of ten muscles were collected from twelve natural RFS runners and ten natural FFS runners. The root mean square (RMS) of each muscle׳s activity was calculated during terminal swing phase and early stance phase. We found significantly lower RMS activity in the tibialis anterior in FFS runners during terminal swing phase, compared to RFS runners. In contrast, the medial and lateral gastrocnemius showed significantly greater RMS activity in terminal swing phase in FFS runners. No significant differences were found during early stance phase for the tibialis anterior or the plantarflexors. Recognizing the differences in muscle activity between FFS and RFS runners is an important step toward understanding how foot strike patterns may contribute to different types of injury. Copyright © 2014 Elsevier Ltd. All rights reserved.
Multi-objective shape optimization of runner blade for Kaplan turbine
NASA Astrophysics Data System (ADS)
Semenova, A.; Chirkov, D.; Lyutov, A.; Chemy, S.; Skorospelov, V.; Pylev, I.
2014-03-01
Automatic runner shape optimization based on extensive CFD analysis proved to be a useful design tool in hydraulic turbomachinery. Previously the authors developed an efficient method for Francis runner optimization. It was successfully applied to the design of several runners with different specific speeds. In present work this method is extended to the task of a Kaplan runner optimization. Despite of relatively simpler blade shape, Kaplan turbines have several features, complicating the optimization problem. First, Kaplan turbines normally operate in a wide range of discharges, thus CFD analysis of each variant of the runner should be carried out for several operation points. Next, due to a high specific speed, draft tube losses have a great impact on the overall turbine efficiency, and thus should be accurately evaluated. Then, the flow in blade tip and hub clearances significantly affects the velocity profile behind the runner and draft tube behavior. All these features are accounted in the present optimization technique. Parameterization of runner blade surface using 24 geometrical parameters is described in details. For each variant of runner geometry steady state three-dimensional turbulent flow computations are carried out in the domain, including wicket gate, runner, draft tube, blade tip and hub clearances. The objectives are maximization of efficiency in best efficiency and high discharge operation points, with simultaneous minimization of cavitation area on the suction side of the blade. Multiobjective genetic algorithm is used for the solution of optimization problem, requiring the analysis of several thousands of runner variants. The method is applied to optimization of runner shape for several Kaplan turbines with different heads.
A Coupled CFD/FEM Structural Analysis to Determine Deformed Shapes of the RSRM Inhibitors
NASA Technical Reports Server (NTRS)
Dill, Richard A.; Whitesides, R. Harold
1996-01-01
Recent trends towards an increase in the stiffness of the acrylonitrile butadiene rubber (NBR) insulation material used in the construction of the redesigned solid rocket motor (RSRM) propellant inhibitors prompted questions about possible effects on RSRM performance. The specific objectives of the computational fluid dynamics (CFD) task included: (1) the definition of pressure loads to calculate the deformed shape of stiffer inhibitors, (2) the calculation of higher port velocities over the inhibitors to determine shifts in the vortex shedding or edge tone frequencies, and (3) the quantification of higher slag impingement and collection rates on the inhibitors and in the submerged nose nozzle cavity.
Hydrodynamics automatic optimization of runner blades for reaction hydraulic turbines
NASA Astrophysics Data System (ADS)
Balint, D.; Câmpian, V.; Nedelcu, D.; Megheles, O.
2012-11-01
The aim of this paper is to optimize the hydrodynamics of the runner blades of hydraulic turbines. The runner presented is an axial Kaplan one, but the methodology is common also to Francis runners. The whole methodology is implemented in the in-house software QTurbo3D. The effect of the runner blades geometry modification upon its hydrodynamics is shown both from energetic and cavitation points of view.
Runner's knowledge of their foot type: do they really know?
Hohmann, Erik; Reaburn, Peter; Imhoff, Andreas
2012-09-01
The use of correct individually selected running shoes may reduce the incidence of running injuries. However, the runner needs to be aware of their foot anatomy to ensure the "correct" footwear is chosen. The purpose of this study was to compare the individual runner's knowledge of their arch type to the arch index derived from a static footprint. We examined 92 recreational runners with a mean age of 35.4±11.4 (12-63) years. A questionnaire was used to investigate the knowledge of the runners about arch height and overpronation. A clinical examination was undertaken using defined criteria and the arch index was analysed using weight-bearing footprints. Forty-five runners (49%) identified their foot arch correctly. Eighteen of the 41 flat-arched runners (44%) identified their arch correctly. Twenty-four of the 48 normal-arched athletes (50%) identified their arch correctly. Three subjects with a high arch identified their arch correctly. Thirty-eight runners assessed themselves as overpronators; only four (11%) of these athletes were positively identified. Of the 34 athletes who did not categorize themselves as overpronators, four runners (12%) had clinical overpronation. The findings of this research suggest that runners possess poor knowledge of both their foot arch and dynamic pronation. Copyright © 2012 Elsevier Ltd. All rights reserved.
Achilles Tendon Properties of Minimalist and Traditionally Shod Runners.
Histen, Katherine; Arntsen, Julia; L'Hereux, Lauren; Heeren, James; Wicki, Benjamin; Saint, Sterling; Aerni, Giselle; Denegar, Craig R; Joseph, Michael F
2017-04-01
Tendon adapts to load through alterations in its composition and mechanical properties. Mechanical adaptation to increased load often involves increases in cross-sectional area (CSA), stiffness, and modulus. Runners exhibit these adaptations. To determine if runners wearing minimalist shoes had larger and stiffer Achilles tendons (AT) than traditionally shod runners. Cross-sectional study of well-trained, traditionally and minimally shod runners. Laboratory assessment of trained runners. 23 men (11 traditional, 12 minimalist) and 8 women (6 traditional, 2 minimalist). Runners wearing minimalist shoes had 4.2 ± 1.6 y of training experience in minimalist shoes. The authors used diagnostic ultrasound and isokinetic dynamometry to generate a force-elongation curve and its derivatives. Minimalist runners had a greater CSA: mean difference (MD) = 9.2 mm 2 , stiffness (MD = 268.1 N/mm), and modulus (MD = 202.9 MPa). ATs of minimalist runners experienced greater stress (MD 8.6 N/mm 2 ) during maximal voluntary isometric contraction of the plantar-flexor muscles due to greater force of contraction (MD 798.9 N). The AT in minimalist runners adapts by increasing size, stiffness, and modulus, which is consistent with our understanding of mechanical adaptation of tendon to increased loading. Increased stress to the AT likely requires a slow transition to minimalist running to allow the AT to adapt without evidence of injury.
Older Runners Retain Youthful Running Economy Despite Biomechanical Differences
Beck, Owen N.; Kipp, Shalaya; Roby, Jaclyn M.; Grabowski, Alena M.; Kram, Rodger; Ortega, Justus D.
2015-01-01
Purpose Sixty-five years of age typically marks the onset of impaired walking economy. However, running economy has not been assessed beyond the age of 65 years. Furthermore, a critical determinant of running economy is the spring-like storage and return of elastic energy from the leg during stance, which is related to leg stiffness. Therefore, we investigated whether runners over the age of 65 years retain youthful running economy and/or leg stiffness across running speeds. Methods Fifteen young and fifteen older runners ran on a force-instrumented treadmill at 2.01, 2.46, and 2.91 m·s−1. We measured their rates of metabolic energy consumption (i.e. metabolic power), ground reaction forces, and stride kinematics. Results There were only small differences in running economy between young and older runners across the range of speeds. Statistically, the older runners consumed 2–9% less metabolic energy than the young runners across speeds (p=0.012). Also, the leg stiffness of older runners was 10–20% lower than that of young runners across the range of speeds (p=0.002) and in contrast to the younger runners, the leg stiffness of older runners decreased with speed (p<0.001). Conclusion Runners beyond 65 years of age maintain youthful running economy despite biomechanical differences. It may be that vigorous exercise, such as running, prevents the age related deterioration of muscular efficiency, and therefore may make everyday activities easier. PMID:26587844
Ribeiro, Ana Paula; João, Silvia Maria Amado; Dinato, Roberto Casanova; Tessutti, Vitor Daniel; Sacco, Isabel Camargo Neves
2015-01-01
Aim/Hypothesis The etiology of plantar fasciitis (PF) has been related to several risk factors, but the magnitude of the plantar load is the most commonly described factor. Although PF is the third most-common injury in runners, only two studies have investigated this factor in runners, and their results are still inconclusive regarding the injury stage. Objective Analyze and compare the plantar loads and vertical loading rate during running of runners in the acute stage of PF to those in the chronic stage of the injury in relation to healthy runners. Methods Forty-five runners with unilateral PF (30 acute and 15 chronic) and 30 healthy control runners were evaluated while running at 12 km/h for 40 meters wearing standardized running shoes and Pedar-X insoles. The contact area and time, maximum force, and force-time integral over the rearfoot, midfoot, and forefoot were recorded and the loading rate (20–80% of the first vertical peak) was calculated. Groups were compared by ANOVAs (p<0.05). Results Maximum force and force-time integral over the rearfoot and the loading rate was higher in runners with PF (acute and chronic) compared with controls (p<0.01). Runners with PF in the acute stage showed lower loading rate and maximum force over the rearfoot compared to runners in the chronic stage (p<0.01). Conclusion Runners with PF showed different dynamic patterns of plantar loads during running over the rearfoot area depending on the injury stage (acute or chronic). In the acute stage of PF, runners presented lower loading rate and forces over the rearfoot, possibly due to dynamic mechanisms related to pain protection of the calcaneal area. PMID:26375815
Videbæk, Solvej; Bueno, Andreas Moeballe; Nielsen, Rasmus Oestergaard; Rasmussen, Sten
2015-07-01
No systematic review has identified the incidence of running-related injuries per 1000 h of running in different types of runners. The purpose of the present review was to systematically search the literature for the incidence of running-related injuries per 1000 h of running in different types of runners, and to include the data in meta-analyses. A search of the PubMed, Scopus, SPORTDiscus, PEDro and Web of Science databases was conducted. Titles, abstracts, and full-text articles were screened by two blinded reviewers to identify prospective cohort studies and randomized controlled trials reporting the incidence of running-related injuries in novice runners, recreational runners, ultra-marathon runners, and track and field athletes. Data were extracted from all studies and comprised for further analysis. An adapted scale was applied to assess the risk of bias. After screening 815 abstracts, 13 original articles were included in the main analysis. Running-related injuries per 1000 h of running ranged from a minimum of 2.5 in a study of long-distance track and field athletes to a maximum of 33.0 in a study of novice runners. The meta-analyses revealed a weighted injury incidence of 17.8 (95% confidence interval [CI] 16.7-19.1) in novice runners and 7.7 (95% CI 6.9-8.7) in recreational runners. Heterogeneity in definitions of injury, definition of type of runner, and outcome measures in the included full-text articles challenged comparison across studies. Novice runners seem to face a significantly greater risk of injury per 1000 h of running than recreational runners.
Saragiotto, Bruno Tirotti; Yamato, Tiê Parma; Lopes, Alexandre Dias
2014-10-01
Qualitative study based on semi-structured interviews. To describe the beliefs and opinions of runners about risk factors associated with running injuries. Despite the health benefits of running, a high prevalence of injury has been reported in runners. Preventive strategies for running injuries may be more successful with a better knowledge of runners' beliefs. A semi-structured interview of recreational runners was based on the question, "What do you think can cause injuries in runners?" Analysis of the interviews was performed in 3 steps: (1) organizing the data into thematic units, (2) reading and reorganizing the data according to frequency of citation, and (3) interpreting and summarizing the data. The runner interviews were continued until no new beliefs and opinions of runners regarding injuries were being added to the data, indicating saturation of the topic. A total of 95 recreational runners (65 men, 30 women) between the ages of 19 and 71 years were interviewed. Of those interviewed, the average running experience was 5.5 years and approximately 45% had experienced a running-related injury in the past. The factors suggested by the runners were divided into extrinsic and intrinsic factors. The most cited extrinsic factors were "not stretching," "excess of training," "not warming up," "lack of strength," and "wearing the wrong shoes." For the intrinsic factors, the main terms cited were "not respecting the body's limitations" and "foot-type changes." Recreational runners mainly attributed injury to factors related to training, running shoes, and exceeding the body's limits. Knowing the factors identified in this study may contribute to the development of better educational strategies to prevent running injuries, as some of the runners' beliefs are not supported by the research literature.
Runtime and Pressurization Analyses of Propellant Tanks
NASA Technical Reports Server (NTRS)
Field, Robert E.; Ryan, Harry M.; Ahuja, Vineet; Hosangadi, Ashvin; Lee, Chung P.
2007-01-01
Multi-element unstructured CFD has been utilized at NASA SSC to carry out analyses of propellant tank systems in different modes of operation. The three regimes of interest at SSC include (a) tank chill down (b) tank pressurization and (c) runtime propellant draw-down and purge. While tank chill down is an important event that is best addressed with long time-scale heat transfer calculations, CFD can play a critical role in the tank pressurization and runtime modes of operation. In these situations, problems with contamination of the propellant by inclusion of the pressurant gas from the ullage causes a deterioration of the quality of the propellant delivered to the test article. CFD can be used to help quantify the mixing and propellant degradation. During tank pressurization under some circumstances, rapid mixing of relatively warm pressurant gas with cryogenic propellant can lead to rapid densification of the gas and loss of pressure in the tank. This phenomenon can cause serious problems during testing because of the resulting decrease in propellant flow rate. With proper physical models implemented, CFD can model the coupling between the propellant and pressurant including heat transfer and phase change effects and accurately capture the complex physics in the evolving flowfields. This holds the promise of allowing the specification of operational conditions and procedures that could minimize the undesirable mixing and heat transfer inherent in propellant tank operation. It should be noted that traditional CFD modeling is inadequate for such simulations because the fluids in the tank are in a range of different sub-critical and supercritical states and elaborate phase change and mixing rules have to be developed to accurately model the interaction between the ullage gas and the propellant. We show a typical run-time simulation of a spherical propellant tank, containing RP-1 in this case, being pressurized with room-temperature nitrogen at 540 R. Nitrogen, shown in blue on the right-hand side of the figures, enters the tank from the diffuser at the top of the figures and impinges on the RP-1, shown in red, while the propellant is being continuously drained at the rate of 1050 lbs/sec through a pipe at the bottom of the tank. The sequence of frames in Figure 1 shows the resultant velocity fields and mixing between nitrogen and RP-1 in a cross-section of the tank at different times. A vortex is seen to form in the incoming nitrogen stream that tends to entrain propellant, mixing it with the pressurant gas. The RP-1 mass fraction contours in Figure 1 are also indicative of the level of mixing and contamination of the propellant. The simulation is used to track the propagation of the pure propellant front as it is drawn toward the exit with the evolution of the mixing processes in the tank. The CFD simulation modeled a total of 10 seconds of run time. As is seen from Figure 1d, after 5.65 seconds the propellant front is nearing the drain pipe, especially near the center of the tank. Behind this pure propellant front is a mixed fluid of compromised quality that would require the test to end when it reaches the exit pipe. Such unsteady simulations provide an estimate of the time that a high-quality propellant supply to the test article can be guaranteed at the modeled mass flow rate. In the final paper, we will discuss simulations of the LOX and propellant tanks at NASA SSC being pressurized by an inert ullage. Detailed comparisons will be made between the CFD simulations and lower order models as well as with test data. Conditions leading to cryo collapse in the tank will also be identified.
Self-excitation in Francis runner during load rejection
NASA Astrophysics Data System (ADS)
Moisan, É.; Giacobbi, D.-B.; Gagnon, M.; Léonard, F.
2014-03-01
Typically, transients such as load rejection generate only a few high vibration cycles in Francis runners. However, in the cases presented in this study, a sustained vibration around a natural frequency was observed on three (3) homologous Francis runners of different sizes during such events. The first two (2) runners were equipped with strain gauges on the blades and displacement sensors positioned circumferentially in the bottom ring and head cover around the runner labyrinth seals. The third runner was monitored only with displacement sensors on non-rotating components. The data from the first two (2) runners provided a better understanding of the parameters influencing the appearance of the high amplitude vibrations and allowed the implementation of a test plan to circumvent the phenomenon during commissioning of the third runner. Based on the measured data, the distributor's closing parameters were optimized to eliminate the vibration observed during load rejection on most of the operating range and reduce it significantly at full load.
NASA Technical Reports Server (NTRS)
De Bothezat, George
1920-01-01
Report presents a theory which gives a complete picture and an exact quantitative analysis of the whole phenomenon of the working of blade screws, but also unites in a continuous whole the entire scale of states of work conceivable for a blade screw. Chapter 1 is devoted to the establishment of the system of fundamental equations relating to the blade screw. Chapter 2 contains the general discussion of the 16 states of work which may establish themselves for a blade screw. The existence of the vortex ring state and the whirling phenomenon are established. All the fundamental functions which enter the blade-screw theory are submitted to a general analytical discussion. The general outline of the curve of the specific function is examined. Two limited cases of the work of the screw, the screw with a zero constructive pitch and the screw with an infinite constructive pitch, are pointed out. Chapter 3 is devoted to the study of the propulsive screw or propeller. (author)
NASA Technical Reports Server (NTRS)
Dulikravich, D. S.
1982-01-01
A fast computer program, GRID3C, was developed to generate multilevel three dimensional, C type, periodic, boundary conforming grids for the calculation of realistic turbomachinery and propeller flow fields. The technique is based on two analytic functions that conformally map a cascade of semi-infinite slits to a cascade of doubly infinite strips on different Riemann sheets. Up to four consecutively refined three dimensional grids are automatically generated and permanently stored on four different computer tapes. Grid nonorthogonality is introduced by a separate coordinate shearing and stretching performed in each of three coordinate directions. The grids are easily clustered closer to the blade surface, the trailing and leading edges and the hub or shroud regions by changing appropriate input parameters. Hub and duct (or outer free boundary) have different axisymmetric shapes. A vortex sheet of arbitrary thickness emanating smoothly from the blade trailing edge is generated automatically by GRID3C. Blade cross sectional shape, chord length, twist angle, sweep angle, and dihedral angle can vary in an arbitrary smooth fashion in the spanwise direction.
Gender differences in gait kinematics in runners with iliotibial band syndrome.
Phinyomark, A; Osis, S; Hettinga, B A; Leigh, R; Ferber, R
2015-12-01
Atypical running gait biomechanics are considered a primary factor in the etiology of iliotibial band syndrome (ITBS). However, a general consensus on the underpinning kinematic differences between runners with and without ITBS is yet to be reached. This lack of consensus may be due in part to three issues: gender differences in gait mechanics, the preselection of discrete biomechanical variables, and/or relatively small sample sizes. Therefore, this study was designed to address two purposes: (a) examining differences in gait kinematics for male and female runners experiencing ITBS at the time of testing and (b) assessing differences in gait kinematics between healthy gender- and age-matched runners as compared with their ITBS counterparts using waveform analysis. Ninety-six runners participated in this study: 48 ITBS and 48 healthy runners. The results show that female ITBS runners exhibited significantly greater hip external rotation compared with male ITBS and female healthy runners. On the contrary, male ITBS runners exhibited significantly greater ankle internal rotation compared with healthy males. These results suggest that care should be taken to account for gender when investigating the biomechanical etiology of ITBS. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Validations of CFD against detailed velocity and pressure measurements in water turbine runner flow
NASA Astrophysics Data System (ADS)
Nilsson, H.; Davidson, L.
2003-03-01
This work compares CFD results with experimental results of the flow in two different kinds of water turbine runners. The runners studied are the GAMM Francis runner and the Hölleforsen Kaplan runner. The GAMM Francis runner was used as a test case in the 1989 GAMM Workshop on 3D Computation of Incompressible Internal Flows where the geometry and detailed best efficiency measurements were made available. In addition to the best efficiency measurements, four off-design operating condition measurements are used for the comparisons in this work. The Hölleforsen Kaplan runner was used at the 1999 Turbine 99 and 2001 Turbine 99 - II workshops on draft tube flow, where detailed measurements made after the runner were used as inlet boundary conditions for the draft tube computations. The measurements are used here to validate computations of the flow in the runner.The computations are made in a single runner blade passage where the inlet boundary conditions are obtained from an extrapolation of detailed measurements (GAMM) or from separate guide vane computations (Hölleforsen). The steady flow in a rotating co-ordinate system is computed. The effects of turbulence are modelled by a low-Reynolds number k- turbulence model, which removes some of the assumptions of the commonly used wall function approach and brings the computations one step further.
Foot strike patterns of recreational and sub-elite runners in a long-distance road race.
Larson, Peter; Higgins, Erin; Kaminski, Justin; Decker, Tamara; Preble, Janine; Lyons, Daniela; McIntyre, Kevin; Normile, Adam
2011-12-01
Although the biomechanical properties of the various types of running foot strike (rearfoot, midfoot, and forefoot) have been studied extensively in the laboratory, only a few studies have attempted to quantify the frequency of running foot strike variants among runners in competitive road races. We classified the left and right foot strike patterns of 936 distance runners, most of whom would be considered of recreational or sub-elite ability, at the 10 km point of a half-marathon/marathon road race. We classified 88.9% of runners at the 10 km point as rearfoot strikers, 3.4% as midfoot strikers, 1.8% as forefoot strikers, and 5.9% of runners exhibited discrete foot strike asymmetry. Rearfoot striking was more common among our sample of mostly recreational distance runners than has been previously reported for samples of faster runners. We also compared foot strike patterns of 286 individual marathon runners between the 10 km and 32 km race locations and observed increased frequency of rearfoot striking at 32 km. A large percentage of runners switched from midfoot and forefoot foot strikes at 10 km to rearfoot strikes at 32 km. The frequency of discrete foot strike asymmetry declined from the 10 km to the 32 km location. Among marathon runners, we found no significant relationship between foot strike patterns and race times.
Mei, Qichang; Fernandez, Justin; Fu, Weijie; Feng, Neng; Gu, Yaodong
2015-08-01
Running is one of the most accessible physical activities and running with and without footwear has attracted extensive attention in the past several years. In this study 18 habitually male unshod runners and 20 habitually male shod runners (all with dominant right feet) participated in a running test. A Vicon motion analysis system was used to capture the kinematics of each participant's lower limb. The in-shoe plantar pressure measurement system was employed to measure the pressure and force exerted on the pressure sensors of the insole. The function of a separate hallux in unshod runners is analyzed through the comparison of plantar pressure parameters. Owing to the different strike patterns in shod and unshod runners, peak dorsiflexion and plantarflexion angle were significantly different. Habitually shod runners exhibited a decreased foot strike angle (FSA) under unshod conditions; and the vertical average loading rate (VALR) of shod runners under unshod conditions was larger than that under shod conditions. This suggests that the foot strike pattern is more important than the shod or unshod running style and runners need to acquire the technique. It can be concluded that for habitually unshod runners the separate hallux takes part of the foot loading and reduces loading to the forefoot under shod conditions. The remaining toes of rearfoot strike (RFS) runners function similarly under unshod conditions. These morphological features of shod and unshod runners should be considered in footwear design to improve sport performance and reduce injury. Copyright © 2015 Elsevier B.V. All rights reserved.
Cai, Congcong; Kong, Pui W
2015-06-01
Controlled laboratory study, cross-sectional. To compare lumbar extensor muscle fatigability, lumbar stabilizing muscle activation, and lower-limb strength between male and female runners with chronic low back pain (LBP) and healthy runners. Little is known about muscle performance in runners with chronic LBP. Eighteen recreational runners with chronic LBP (9 men, 9 women; mean age, 27.8 years) and 18 healthy recreational runners (9 men, 9 women; mean age, 24.6 years) were recruited. The median frequency slopes for bilateral iliocostalis and longissimus were calculated from electromyographic signals captured during a 2-minute Sorensen test. The thickness changes of the transversus abdominis and lumbar multifidus between resting and contraction were measured using an ultrasound scanner. Peak concentric torques of the bilateral hip extensors, hip abductors, and knee extensors were measured using an isokinetic dynamometer at 60°/s. The average values for both sides were used for statistical analysis. When averaged across sexes, peak knee extensor torque was 12.2% lower in the LBP group compared to the healthy group (mean difference, 0.29 Nm/kg; 95% confidence interval: 0.06, 0.53; P = .016). Male runners with chronic LBP exhibited smaller lumbar multifidus thickness changes compared to healthy male runners (mean difference, 0.13 cm; 95% confidence interval: 0.01, 0.25; P = .033). No other group differences were observed. Runners with chronic LBP exhibited diminished knee extensor strength compared to healthy runners. Male runners with chronic LBP demonstrated additional deficits in lumbar multifidus activation.
Design optimization of a high specific speed Francis turbine runner
NASA Astrophysics Data System (ADS)
Enomoto, Y.; Kurosawa, S.; Kawajiri, H.
2012-11-01
Francis turbine is used in many hydroelectric power stations. This paper presents the development of hydraulic performance in a high specific speed Francis turbine runner. In order to achieve the improvements of turbine efficiency throughout a wide operating range, a new runner design method which combines the latest Computational Fluid Dynamics (CFD) and a multi objective optimization method with an existing design system was applied in this study. The validity of the new design system was evaluated by model performance tests. As the results, it was confirmed that the optimized runner presented higher efficiency compared with an originally designed runner. Besides optimization of runner, instability vibration which occurred at high part load operating condition was investigated by model test and gas-liquid two-phase flow analysis. As the results, it was confirmed that the instability vibration was caused by oval cross section whirl which was caused by recirculation flow near runner cone wall.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-15
... FR 10087) announcing the CSX Transportation Railroad's (CSXT) request for a waiver to operate RailRunner equipment in RailRunner only operations; operate RailRunner equipment commingled with RoadRailer bi-modal equipment; and RailRunner equipment operating behind various conventional railcars. On...
NASA Astrophysics Data System (ADS)
Miclosina, C. O.; Balint, D. I.; Campian, C. V.; Frunzaverde, D.; Ion, I.
2012-11-01
This paper deals with the optimization of the axial hydraulic turbines of Kaplan type. The optimization of the runner blade is presented systematically from two points of view: hydrodynamic and constructive. Combining these aspects in order to gain a safer operation when unsteady effects occur in the runner of the turbine is attempted. The design and optimization of the runner blade is performed with QTurbo3D software developed at the Center for Research in Hydraulics, Automation and Thermal Processes (CCHAPT) from "Eftimie Murgu" University of Resita, Romania. QTurbo3D software offers possibilities to design the meridian channel of hydraulic turbines design the blades and optimize the runner blade. 3D modeling and motion analysis of the runner blade operating mechanism are accomplished using SolidWorks software. The purpose of motion study is to obtain forces, torques or stresses in the runner blade operating mechanism, necessary to estimate its lifetime. This paper clearly states the importance of combining the hydrodynamics with the structural design in the optimization procedure of the runner of hydraulic turbines.
Tinea pedis in European marathon runners.
Lacroix, C; Baspeyras, M; de La Salmonière, P; Benderdouche, M; Couprie, B; Accoceberry, I; Weill, F X; Derouin, F; Feuilhade de Chauvin, M
2002-03-01
Epidemiological studies suggest that 15% of the population in industrial countries suffer from tinea pedis (athlete's foot) and that persons who do sports are a high-risk population. To investigate the responsibility of dermatophytes in interdigital lesions of the feet in European marathon runners and to identify associated risk factors. Runners of the 14th Médoc Marathon (n = 147) were interviewed on risk factors for tinea pedis and underwent physical and mycological examinations. Interdigital lesions of the feet were found in 66 runners (45%). A dermatophyte was isolated in 45 runners (31%), 12 of whom were asymptomatic. Trichophyton interdigitale and T. rubrum accounted for 49% and 35.5%, respectively, of the cases of tinea pedis. Thirty-three (22%) of the 102 runners free of dermatophyte infection had lesions resembling those of tinea pedis. Increasing age and use of communal bathing facilities were predictive of T. rubrum culture. Marathon runners are at high risk for tinea pedis, but dermatophytes are responsible for only half of the foot lesions found in runners. The existence of asymptomatic carriers calls for prophylactic measures.
Did recent world record marathon runners employ optimal pacing strategies?
Angus, Simon D
2014-01-01
We apply statistical analysis of high frequency (1 km) split data for the most recent two world-record marathon runs: Run 1 (2:03:59, 28 September 2008) and Run 2 (2:03:38, 25 September 2011). Based on studies in the endurance cycling literature, we develop two principles to approximate 'optimal' pacing in the field marathon. By utilising GPS and weather data, we test, and then de-trend, for each athlete's field response to gradient and headwind on course, recovering standardised proxies for power-based pacing traces. The resultant traces were analysed to ascertain if either runner followed optimal pacing principles; and characterise any deviations from optimality. Whereas gradient was insignificant, headwind was a significant factor in running speed variability for both runners, with Runner 2 targeting the (optimal) parallel variation principle, whilst Runner 1 did not. After adjusting for these responses, neither runner followed the (optimal) 'even' power pacing principle, with Runner 2's macro-pacing strategy fitting a sinusoidal oscillator with exponentially expanding envelope whilst Runner 1 followed a U-shaped, quadratic form. The study suggests that: (a) better pacing strategy could provide elite marathon runners with an economical pathway to significant performance improvements at world-record level; and (b) the data and analysis herein is consistent with a complex-adaptive model of power regulation.
Running with horizontal pulling forces: the benefits of towing.
Grabowski, Alena M; Kram, Rodger
2008-10-01
Towing, or running with a horizontal pulling force, is a common technique used by adventure racing teams. During an adventure race, the slowest person on a team determines the team's overall performance. To improve overall performance, a faster runner tows a slower runner with an elastic cord attached to their waists. Our purpose was to create and validate a model that predicts the optimal towing force needed by two runners to achieve their best overall performance. We modeled the effects of towing forces between two runners that differ in solo 10-km performance time and/or body mass. We calculated the overall time that could be saved with towing for running distances of 10, 20, and 42.2-km based on equations from previous research. Then, we empirically tested our 10-km model on 15 runners. Towing improved overall running performance considerably and our model accurately predicted this performance improvement. For example, if two runners (a 70 kg runner with a 35 min solo 10-km time and a 70-kg runner with a 50-min solo 10-km time) maintain an optimal towing force throughout a 10-km race, they can improve overall performance by 15%, saving almost 8 min. Ultimately, the race performance time and body mass of each runner determine the optimal towing force.
Infectious episodes in runners before and after a roadrace.
Nieman, D C; Johanssen, L M; Lee, J W
1989-09-01
Various researchers have implied that regular and moderate exercise training may improve the ability of the immune system to protect the host from infection. In contrast, acute, maximal, and exhaustive exercise may have negative effects of the immune system. This study compared the incidence of infectious episodes in 273 runners during a two month training period prior to a 5 K, 10 K, or half-marathon race. In addition, the effect of the race experience on infectious episodes was studied. Twenty-five percent of the runners training more than 15 miles per week reported at least one infectious episode as compared with 34.3% of runners training less than 15 miles per week (p = 0.09). Only 6.8% of the runners preparing for the half-marathon race reported becoming sick with the flu versus 17.9% of the 5 K and 10 K runners (p = 0.067). During the week following the roadrace, runners did not report an increase in infectious episodes as compared to the week prior to the race. These trends suggest that runners with a more serious commitment to regular exercise may experience less infectious episodes than recreational runners because of both direct and indirect affects on immunosurveillance. In addition, the stressful race experience does not appear to increase risk of acquiring an acute respiratory infection.
A field test for determining the speed obtained through anaerobic glycolysis in runners.
Borsetto, C; Ballarin, E; Casoni, I; Cellini, M; Vitiello, P; Conconi, F
1989-10-01
A field test for the evaluation of the speed generated by the anaerobic lactacid mechanism has been developed in runners. The test consists of 1200 m of continuous running: in the first 1000 m the speed corresponding to the anaerobic threshold is progressively reached; in the last 200 m an all-out sprint is performed. The speed at the anaerobic threshold is subtracted from the speed reached in the final 200-m all-out sprint. In 39 runners examined (marathon runners, n = 13; 5000-10000-m runners, n = 10; 400-800-m runners, n = 7; sprinters, n = 9), the additional speed generated above the anaerobic threshold was correlated with the venous blood lactate concentration reached 5 min after the all-out effort (r = 0.93). The anaerobic speeds measured by the test were in keeping with the characteristics of the runners under study, i.e., anaerobic speeds were highest for the sprinters, intermediate for the middle-distance runners, and lowest for the marathon runners. Since the speed generated above the anaerobic threshold by the aerobic fuel breakdown can be subtracted, the contribution of creatine phosphate is minimal, and the speed exceeding the anaerobic threshold is highly correlated with lactate accumulation, the present test should measure the speed generated by anaerobic glycolysis.
The Influence of a Bout of Exertion on Novice Barefoot Running Dynamics
Hashish, Rami; Samarawickrame, Sachithra D.; Baker, Lucinda; Salem, George J.
2016-01-01
Barefoot, forefoot strike (FFS) running has recently risen in popularity. Relative to shod, rear-foot strike (RFS) running, employing a FFS is associated with heightened triceps surae muscle activation and ankle mechanical demand. Novice to this pattern, it is plausible that habitually shod RFS runners exhibit fatigue to the triceps surae when acutely transitioning to barefoot running, thereby limiting their ability to attenuate impact. Therefore, the purpose was to determine how habitually shod RFS runners respond to an exertion bout of barefoot running, operationally defined as a barefoot run 20% of mean daily running distance. Twenty-one RFS runners performed novice barefoot running, before and after exertion. Ankle peak torque, triceps surae EMG median frequency, foot-strike patterns, joint energy absorption, and loading rates were evaluated. Of the 21 runners, 6 maintained a RFS, 10 adopted a mid-foot strike (MFS), and 5 adopted a FFS during novice barefoot running. In-response to exertion, MFS and FFS runners demonstrated reductions in peak torque, median frequency, and ankle energy absorption, and an increase in loading rate. RFS runners demonstrated reductions in peak torque and loading rate. These results indicate that a short bout of running may elicit fatigue to novice barefoot runners, limiting their ability to attenuate impact. Key points In response to exertion, novice barefoot runners demonstrate fatigue to their soleus. In response to exertion, novice barefoot runners demonstrate a reduction in ankle energy absorption In response to exertion, novice barefoot runners demonstrate an increase in loading rate PMID:27274672
The Influence of a Bout of Exertion on Novice Barefoot Running Dynamics.
Hashish, Rami; Samarawickrame, Sachithra D; Baker, Lucinda; Salem, George J
2016-06-01
Barefoot, forefoot strike (FFS) running has recently risen in popularity. Relative to shod, rear-foot strike (RFS) running, employing a FFS is associated with heightened triceps surae muscle activation and ankle mechanical demand. Novice to this pattern, it is plausible that habitually shod RFS runners exhibit fatigue to the triceps surae when acutely transitioning to barefoot running, thereby limiting their ability to attenuate impact. Therefore, the purpose was to determine how habitually shod RFS runners respond to an exertion bout of barefoot running, operationally defined as a barefoot run 20% of mean daily running distance. Twenty-one RFS runners performed novice barefoot running, before and after exertion. Ankle peak torque, triceps surae EMG median frequency, foot-strike patterns, joint energy absorption, and loading rates were evaluated. Of the 21 runners, 6 maintained a RFS, 10 adopted a mid-foot strike (MFS), and 5 adopted a FFS during novice barefoot running. In-response to exertion, MFS and FFS runners demonstrated reductions in peak torque, median frequency, and ankle energy absorption, and an increase in loading rate. RFS runners demonstrated reductions in peak torque and loading rate. These results indicate that a short bout of running may elicit fatigue to novice barefoot runners, limiting their ability to attenuate impact. Key pointsIn response to exertion, novice barefoot runners demonstrate fatigue to their soleus.In response to exertion, novice barefoot runners demonstrate a reduction in ankle energy absorptionIn response to exertion, novice barefoot runners demonstrate an increase in loading rate.
Zdziarski, Laura Ann; Chen, Cong; Horodyski, Marybeth; Vincent, Kevin R.; Vincent, Heather K.
2017-01-01
Objective To determine the differences in kinematic, cardiopulmonary, and metabolic responses between overweight and healthy weight runners at a self-selected and standard running speed. Design Comparative descriptive study. Setting Tertiary care institution, university-affiliated research laboratory. Participants Overweight runners (n = 21) were matched with runners of healthy weight (n = 42). Methods Participants ran at self-selected and standardized speeds (13.6 km/h). Sagittal plane joint kinematics were captured simultaneously with cardiopulmonary and metabolic measures using a motion capture system and portable gas analyzer, respectively. Main Outcome Measurements Spatiotemporal parameters (cadence, step width and length, center of gravity displacement, stance time) joint kinematics, oxygen cost, heart rate, ventilation and energy expenditure. Results At the self-selected speed, overweight individuals ran slower (8.5 ± 1.3 versus 10.0 ± 1.6 km/h) and had slower cadence (163 versus 169 steps/min; P < .05). The sagittal plane range of motion (ROM) for flexion-extension at the ankle, knee, hip, and anterior pelvic tilt were all less in overweight runners compared to healthy weight runners (all P < .05). At self-selected speed and 13.6 km/h, energy expenditure was higher in the overweight runners compared to their healthy weight counterparts (P < .05). At 13.6 km/h, only the frontal hip and pelvis ROM were higher in the overweight versus the healthy weight runners (P < .05), and energy expenditure, net energy cost, and minute ventilation were higher in the overweight runners compared to the healthy weight runners (P < .05). Conclusion At self-selected running speeds, the overweight runners demonstrated gait strategies (less joint ROM, less vertical displacement, and shorter step lengths) that resulted in cardiopulmonary and energetic responses similar to those of healthy weight individuals. PMID:26146194
Prospective comparison of running injuries between shod and barefoot runners.
Altman, Allison R; Davis, Irene S
2016-04-01
Advocates of barefoot running suggest that it is more natural and may be a way to minimise injury risk. In contrast, opponents believe shoes are needed to adequately cushion and support the foot. However, to date, there have been no prospective studies of injury patterns in barefoot and shod runners. The purpose of this study was to compare the incidence and rate of injuries between shod and barefoot runners. A prospective survey was conducted over the course of a year among 201 (107 barefoot and 94 shod) adult runners. Information regarding injuries and mileage was logged monthly using a custom, web-based database program. The number of injured runners, number of injuries per runner and injury rates were compared between habitual barefoot and habitual shod runners. Both musculoskeletal and plantar surface injuries were assessed. Statistically fewer overall, diagnosed, musculoskeletal injuries/runner were noted in the barefoot group. However, injury rates were not statistically different between groups due to significantly less mileage run in the barefoot group. As expected, barefoot runners sustained a statistically greater number of injuries to the plantar surface of the foot. The descriptive analysis suggests a greater number of calf injuries, but lower number of knee and hip injuries in the barefoot group. Additionally barefoot runners reported less plantar fasciitis than the shod group. Barefoot running is associated with fewer overall musculoskeletal injuries/runner, but similar injury rates. A larger scale cohort is needed to more accurately assess differences in individual injuries between these two groups. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Goss, Donald L; Lewek, Michael; Yu, Bing; Ware, William B; Teyhen, Deydre S; Gross, Michael T
2015-06-01
The injury incidence rate among runners is approximately 50%. Some individuals have advocated using an anterior-foot-strike pattern to reduce ground reaction forces and injury rates that they attribute to a rear-foot-strike pattern. The proportion of minimalist shoe wearers who adopt an anterior-foot-strike pattern remains unclear. To evaluate the accuracy of self-reported foot-strike patterns, compare negative ankle- and knee-joint angular work among runners using different foot-strike patterns and wearing traditional or minimalist shoes, and describe average vertical-loading rates. Descriptive laboratory study. Research laboratory. A total of 60 healthy volunteers (37 men, 23 women; age = 34.9 ± 8.9 years, height = 1.74 ± 0.08 m, mass = 70.9 ± 13.4 kg) with more than 6 months of experience wearing traditional or minimalist shoes were instructed to classify their foot-strike patterns. Participants ran in their preferred shoes on an instrumented treadmill with 3-dimensional motion capture. Self-reported foot-strike patterns were compared with 2-dimensional video assessments. Runners were classified into 3 groups based on video assessment: traditional-shoe rear-foot strikers (TSR; n = 22), minimalist-shoe anterior-foot strikers (MSA; n = 21), and minimalist-shoe rear-foot strikers (MSR; n = 17). Ankle and knee negative angular work and average vertical-loading rates during stance phase were compared among groups. Only 41 (68.3%) runners reported foot-strike patterns that agreed with the video assessment (κ = 0.42, P < .001). The TSR runners demonstrated greater ankle-dorsiflexion and knee-extension negative work than MSA and MSR runners (P < .05). The MSA (P < .001) and MSR (P = .01) runners demonstrated greater ankle plantar-flexion negative work than TSR runners. The MSR runners demonstrated a greater average vertical-loading rate than MSA and TSR runners (P < .001). Runners often cannot report their foot-strike patterns accurately and may not automatically adopt an anterior-foot-strike pattern after transitioning to minimalist running shoes.
7 CFR 319.56-54 - French beans and runner beans from Kenya.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 5 2014-01-01 2014-01-01 false French beans and runner beans from Kenya. 319.56-54... § 319.56-54 French beans and runner beans from Kenya. French beans (Phaseolus vulgaris L.) and runner beans (Phaseolus coccineus L.) may be imported into the United States from Kenya only under the...
7 CFR 319.56-54 - French beans and runner beans from Kenya.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 5 2012-01-01 2012-01-01 false French beans and runner beans from Kenya. 319.56-54... § 319.56-54 French beans and runner beans from Kenya. French beans (Phaseolus vulgaris L.) and runner beans (Phaseolus coccineus L.) may be imported into the United States from Kenya only under the...
7 CFR 319.56-54 - French beans and runner beans from Kenya.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 5 2013-01-01 2013-01-01 false French beans and runner beans from Kenya. 319.56-54... § 319.56-54 French beans and runner beans from Kenya. French beans (Phaseolus vulgaris L.) and runner beans (Phaseolus coccineus L.) may be imported into the United States from Kenya only under the...
ERIC Educational Resources Information Center
Grau, Stefan; Maiwald, Christian; Krauss, Inga; Axmann, Detlef; Horstmann, Thomas
2008-01-01
The purpose of this study was to assess how participant matching influences biomechanical variables when comparing healthy runners and runners with iliotibial band syndrome (ITBS). We examined 52 healthy runners (CO) and 18 with ITBS, using three-dimensional kinematics and pressure distribution. The study population was matched in three ways and…
Performance Capability of Single-Cavity Vortex Gaseous Nuclear Rockets
NASA Technical Reports Server (NTRS)
Ragsdale, Robert G.
1963-01-01
An analysis was made to determine the maximum powerplant thrust-to-weight ratio possible with a single-cavity vortex gaseous reactor in which all the hydrogen propellant must diffuse through a fuel-rich region. An assumed radial temperature profile was used to represent conduction, convection, and radiation heat-transfer effects. The effect of hydrogen property changes due to dissociation and ionization was taken into account in a hydrodynamic computer program. It is shown that, even for extremely optimistic assumptions of reactor criticality and operating conditions, such a system is limited to reactor thrust-to-weight ratios of about 1.2 x 10(exp -3) for laminar flow. For turbulent flow, the maximum thrust-to-weight ratio is less than 10(exp -3). These low thrusts result from the fact that the hydrogen flow rate is limited by the diffusion process. The performance of a gas-core system with a specific impulse of 3000 seconds and a powerplant thrust-to-weight ratio of 10(exp -2) is shown to be equivalent to that of a 1000-second advanced solid-core system. It is therefore concluded that a single-cavity vortex gaseous reactor in which all the hydrogen must diffuse through the nuclear fuel is a low-thrust device and offers no improvement over a solid-core nuclear-rocket engine. To achieve higher thrust, additional hydrogen flow must be introduced in such a manner that it will by-pass the nuclear fuel. Obviously, such flow must be heated by thermal radiation. An illustrative model of a single-cavity vortex system employing supplementary flow of hydrogen through the core region is briefly examined. Such a system appears capable of thrust-to-weight ratios of approximately 1 to 10. For a high-impulse engine, this capability would be a considerable improvement over solid-core performance. Limits imposed by thermal radiation heat transfer to cavity walls are acknowledged but not evaluated. Alternate vortex concepts that employ many parallel vortices to achieve higher hydrogen flow rates offer the possibility of sufficiently high thrust-to-weight ratios, if they are not limited by short thermal-radiation path lengths.
Luedke, Lace E; Heiderscheit, Bryan C; Williams, D S Blaise; Rauh, Mitchell J
2015-11-01
High school cross country runners have a high incidence of overuse injuries, particularly to the knee and shin. As lower extremity strength is modifiable, identification of strength attributes that contribute to anterior knee pain (AKP) and shin injuries may influence prevention and management of these injuries. To determine if a relationship existed between isometric hip abductor, knee extensor and flexor strength and the incidence of AKP and shin injury in high school cross country runners. Sixty-eight high school cross country runners (47 girls, 21 boys) participated in the study. Isometric strength tests of hip abductors, knee extensors and flexors were performed with a handheld dynamometer. Runners were prospectively followed during the 2014 interscholastic cross country season for occurrences of AKP and shin injury. Bivariate logistic regression was used to examine risk relationships between strength values and occurrence of AKP and shin injury. During the season, three (4.4%) runners experienced AKP and 13 (19.1%) runners incurred a shin injury. Runners in the tertiles indicating weakest hip abductor (chi-square = 6.140; p=0.046), knee extensor (chi-square = 6.562; p=0.038), and knee flexor (chi-square = 6.140; p=0.046) muscle strength had a significantly higher incidence of AKP. Hip and knee muscle strength was not significantly associated with shin injury. High school cross country runners with weaker hip abductor, knee extensor and flexor muscle strength had a higher incidence of AKP. Increasing hip and knee muscle strength may reduce the likelihood of AKP in high school cross country runners. 2b.
Evaluation of the dynamic behavior of a Pelton runner based on strain gauge measurements
NASA Astrophysics Data System (ADS)
Mack, Reiner; Probst, Christian
2016-11-01
A reliable mechanical design of Pelton runners is very important in the layout of new installations and modernizations. Especially in horizontal machines, where the housing is not embedded into concrete, a rupture of a runner bucket can have severe consequences. Even if a crack in the runner is detected on time, the outage time that follows the malfunction of the runner is shortening the return of investment. It is a fact that stresses caused by the runner rotation and the jet forces are superposed by high frequent dynamic stresses. In case of resonance it even can be the dominating effect that is limiting the lifetime of a runner. Therefore a clear understanding of the dynamic mechanisms is essential for a safe runner design. This paper describes the evaluation of the dynamic behavior of a Pelton runner installed in a model turbine based on strain gauge measurements. Equipped with strain gauges at the root area of the buckets, the time responses of the strains under the influence of various operational parameters were measured. As a result basic theories for the jet bucket excitation were verified and the influence of the water mass was detected by evaluating the frequency shift in case of resonance. Furthermore, the influence of the individual bucket masses onto the dynamic behaviour for different mode shapes got measured.
Cheung, Roy T H; Wong, Rodney Y L; Chung, Tim K W; Choi, R T; Leung, Wendy W Y; Shek, Diana H Y
2017-06-01
Compared to competitive runners, recreational runners appear to be more prone to injuries, which have been associated with foot strike patterns. Surprisingly, only few studies had examined the foot strike patterns outside laboratories. Therefore, this study compared the foot strike patterns in recreational runners at outdoor tracks with previously reported data. We also investigated the relationship between foot strike pattern, speed, and footwear in this cohort. Among 434 recreational runners analysed, 89.6% of them landed with rearfoot strike (RFS). Only 6.9 and 3.5% landed with midfoot and forefoot, respectively. A significant shift towards non-RFS was observed in our cohort, when compared with previously reported data. When speed increased by 1 m/s, the odds of having forefoot strike and midfoot strike relative to RFS increased by 2.3 times and 2.6 times, respectively. Runners were 9.2 times more likely to run with a forefoot strike in minimalists compared to regular running shoes, although 70% of runners in minimalists continued to use a RFS. These findings suggest that foot strike pattern may differ across running conditions and runners should consider these factors in order to mitigate potential injury.
Fat intake and injury in female runners.
Gerlach, Kristen E; Burton, Harold W; Dorn, Joan M; Leddy, John J; Horvath, Peter J
2008-01-03
Our purpose was to determine the relationship between energy intake, energy availability, dietary fat and lower extremity injury in adult female runners. We hypothesized that runners who develop overuse running-related injuries have lower energy intakes, lower energy availability and lower fat intake compared to non-injured runners. Eighty-six female subjects, running a minimum of 20 miles/week, completed a food frequency questionnaire and informed us about injury incidence over the next year. Injured runners had significantly lower intakes of total fat (63 +/- 20 vs. 80 +/- 50 g/d) and percentage of kilocalories from fat (27 +/- 5 vs. 30 +/- 8 %) compared with non-injured runners. A logistic regression analysis found that fat intake was the best dietary predictor, correctly identifying 64% of future injuries. Lower energy intake and lower energy availability approached, but did not reach, a significant association with overuse injury in this study. Fat intake is likely associated with injury risk in female runners. By documenting these associations, better strategies can be developed to reduce running injuries in women.
Lattice Boltzmann study of chemically-driven self-propelled droplets.
Fadda, F; Gonnella, G; Lamura, A; Tiribocchi, A
2017-12-19
We numerically study the behavior of self-propelled liquid droplets whose motion is triggered by a Marangoni-like flow. This latter is generated by variations of surfactant concentration which affect the droplet surface tension promoting its motion. In the present paper a model for droplets with a third amphiphilic component is adopted. The dynamics is described by Navier-Stokes and convection-diffusion equations, solved by the lattice Boltzmann method coupled with finite-difference schemes. We focus on two cases. First, the study of self-propulsion of an isolated droplet is carried on and, then, the interaction of two self-propelled droplets is investigated. In both cases, when the surfactant migrates towards the interface, a quadrupolar vortex of the velocity field forms inside the droplet and causes the motion. A weaker dipolar field emerges instead when the surfactant is mainly diluted in the bulk. The dynamics of two interacting droplets is more complex and strongly depends on their reciprocal distance. If, in a head-on collision, droplets are close enough, the velocity field initially attracts them until a motionless steady state is achieved. If the droplets are vertically shifted, the hydrodynamic field leads to an initial reciprocal attraction followed by a scattering along opposite directions. This hydrodynamic interaction acts on a separation of some droplet radii otherwise it becomes negligible and droplets motion is only driven by the Marangoni effect. Finally, if one of the droplets is passive, this latter is generally advected by the fluid flow generated by the active one.
NASA Astrophysics Data System (ADS)
Bernier, Caroline; Gazzola, Mattia; Ronsse, Renaud; Chatelain, Philippe
2017-11-01
We present a 2D fluid-structure interaction simulation method with a specific focus on articulated and actuated structures. The proposed algorithm combines a viscous Vortex Particle-Mesh (VPM) method based on a penalization technique and a Multi-Body System (MBS) solver. The hydrodynamic forces and moments acting on the structure parts are not computed explicitly from the surface stresses; they are rather recovered from the projection and penalization steps within the VPM method. The MBS solver accounts for the body dynamics via the Euler-Lagrange formalism. The deformations of the structure are dictated by the hydrodynamic efforts and actuation torques. Here, we focus on simplified swimming structures composed of neutrally buoyant ellipses connected by virtual joints. The joints are actuated through a simple controller in order to reproduce the swimming patterns of an eel-like swimmer. The method enables to recover the histories of torques applied on each hinge along the body. The method is verified on several benchmarks: an impulsively started elastically mounted cylinder and free swimming articulated fish-like structures. Validation will be performed by means of an experimental swimming robot that reproduces the 2D articulated ellipses.
The Performance of a Subsonic Diffuser Designed for High Speed Turbojet-Propelled Flight
NASA Technical Reports Server (NTRS)
Biesiadny, Thomas J. (Technical Monitor); Wendt, Bruce J.
2004-01-01
An initial-phase subsonic diffuser has been designed for the turbojet flowpath of the hypersonic x43B flight demonstrator vehicle. The diffuser fit into a proposed mixed-compression supersonic inlet system and featured a cross-sectional shape transitioning flowpath (high aspect ratio rectangular throat-to-circular engine face) and a centerline offset. This subsonic diffuser has been fabricated and tested at the W1B internal flow facility at NASA Glenn Research Center. At an operating throat Mach number of 0.79, baseline Pitot pressure recovery was found to be just under 0.9, and DH distortion intensity was about 0.4 percent. The diffuser internal flow stagnated, but did not separate on the offset surface of this initial-phase subsonic diffuser. Small improvements in recovery (+0.4 percent) and DH distortion (-32 percent) were obtained from using vane vortex generator flow control applied just downstream of the diffuser throat. The optimum vortex generator array patterns produced inflow boundary layer divergence (local downwash) on the offset surface centerline of the diffuser, and an inflow boundary layer convergence (local upwash) on the centerline of the opposite surface.
Williams, D S Blaise; Tierney, Robin N; Butler, Robert J
2014-01-01
Runners with high medial longitudinal arch structure demonstrate unique kinematics and kinetics that may lead to running injuries. The mobility of the midfoot as measured by the change in arch height is also suspected to play a role in lower extremity function during running. The effect of arch mobility in high-arched runners is an important factor in prescribing footwear, training, and rehabilitating the running athlete after injury. To examine the effect of medial longitudinal arch mobility on running kinematics, ground reaction forces, and loading rates in high-arched runners. Cross-sectional study. Human movement research laboratory. A total of 104 runners were screened for arch height. Runners were then identified as having high arches if the arch height index was greater than 0.5 SD above the mean. Of the runners with high arches, 11 rigid runners with the lowest arch mobility (R) were compared with 8 mobile runners with the highest arch mobility (M). Arch mobility was determined by calculating the left arch height index in all runners. Three-dimensional motion analysis of running over ground. Rearfoot and tibial angular excursions, eversion-to-tibial internal-rotation ratio, vertical ground reaction forces, and the associated loading rates. Runners with mobile arches exhibited decreased tibial internal-rotation excursion (mobile: 5.6° ± 2.3° versus rigid: 8.0° ± 3.0°), greater eversion-to-tibial internal-rotation ratio (mobile: 2.1 ± 0.8 versus rigid: 1.5 ± 0.5), decreased second peak vertical ground reaction force values (mobile: 2.3 ± 0.2 × body weight versus rigid: 2.4 ± 0.1 × body weight), and decreased vertical loading rate values (mobile: 55.7 ± 14.1 × body weight/s versus rigid: 65.9 ± 11.4 × body weight/s). Based on the results of this study, it appears that runners with high arch structure but differing arch mobility exhibited differences in select lower extremity movement patterns and forces. Future authors should investigate the impact of arch mobility on running-related injuries.
Goss, Donald L.; Lewek, Michael; Yu, Bing; Ware, William B.; Teyhen, Deydre S.; Gross, Michael T.
2015-01-01
Context The injury incidence rate among runners is approximately 50%. Some individuals have advocated using an anterior–foot-strike pattern to reduce ground reaction forces and injury rates that they attribute to a rear–foot-strike pattern. The proportion of minimalist shoe wearers who adopt an anterior–foot-strike pattern remains unclear. Objective To evaluate the accuracy of self-reported foot-strike patterns, compare negative ankle- and knee-joint angular work among runners using different foot-strike patterns and wearing traditional or minimalist shoes, and describe average vertical-loading rates. Design Descriptive laboratory study. Setting Research laboratory. Patients or Other Participants A total of 60 healthy volunteers (37 men, 23 women; age = 34.9 ± 8.9 years, height = 1.74 ± 0.08 m, mass = 70.9 ± 13.4 kg) with more than 6 months of experience wearing traditional or minimalist shoes were instructed to classify their foot-strike patterns. Intervention(s) Participants ran in their preferred shoes on an instrumented treadmill with 3-dimensional motion capture. Main Outcome Measure(s) Self-reported foot-strike patterns were compared with 2-dimensional video assessments. Runners were classified into 3 groups based on video assessment: traditional-shoe rear-foot strikers (TSR; n = 22), minimalist-shoe anterior-foot strikers (MSA; n = 21), and minimalist-shoe rear-foot strikers (MSR; n = 17). Ankle and knee negative angular work and average vertical-loading rates during stance phase were compared among groups. Results Only 41 (68.3%) runners reported foot-strike patterns that agreed with the video assessment (κ = 0.42, P < .001). The TSR runners demonstrated greater ankle-dorsiflexion and knee-extension negative work than MSA and MSR runners (P < .05). The MSA (P < .001) and MSR (P = .01) runners demonstrated greater ankle plantar-flexion negative work than TSR runners. The MSR runners demonstrated a greater average vertical-loading rate than MSA and TSR runners (P < .001). Conclusions Runners often cannot report their foot-strike patterns accurately and may not automatically adopt an anterior–foot-strike pattern after transitioning to minimalist running shoes. PMID:26098391
Goss, Donald L; Lewek, Michael; Yu, Bing; Ware, William B; Teyhen, Deydre S; Gross, Michael T
2015-02-19
Context : The injury incidence rate among runners is approximately 50%. Some individuals have advocated using an anterior-foot-strike pattern to reduce ground reaction forces and injury rates that they attribute to a rear-foot-strike pattern. The proportion of minimalist shoe wearers who adopt an anterior-foot-strike pattern remains unclear. Objective : To evaluate the accuracy of self-reported foot-strike patterns, compare negative ankle- and knee-joint angular work among runners using different foot-strike patterns and wearing traditional or minimalist shoes, and describe average vertical-loading rates. Design : Descriptive laboratory study. Setting : Research laboratory. Patients or Other Participants : A total of 60 healthy volunteers (37 men, 23 women; age = 34.9 ± 8.9 years, height = 1.74 ± 0.08 m, mass = 70.9 ± 13.4 kg) with more than 6 months of experience wearing traditional or minimalist shoes were instructed to classify their foot-strike patterns. Intervention(s) : Participants ran in their preferred shoes on an instrumented treadmill with 3-dimensional motion capture. Main Outcome Measure(s) : Self-reported foot-strike patterns were compared with 2-dimensional video assessments. Runners were classified into 3 groups based on video assessment: traditional-shoe rear-foot strikers (TSR; n = 22), minimalist-shoe anterior-foot strikers (MSA; n = 21), and minimalist-shoe rear-foot strikers (MSR; n = 17). Ankle and knee negative angular work and average vertical-loading rates during stance phase were compared among groups. Results : Only 41 (68.3%) runners reported foot-strike patterns that agreed with the video assessment (κ = 0.42, P < .001). The TSR runners demonstrated greater ankle-dorsiflexion and knee-extension negative work than MSA and MSR runners (P < .05). The MSA (P < .001) and MSR (P = .01) runners demonstrated greater ankle plantar-flexion negative work than TSR runners. The MSR runners demonstrated a greater average vertical-loading rate than MSA and TSR runners (P < .001). Conclusions : Runners often cannot report their foot-strike patterns accurately and may not automatically adopt an anterior-foot-strike pattern after transitioning to minimalist running shoes.
Metabolic, Cardiopulmonary, and Gait Profiles of Recently Injured and Noninjured Runners
Peng, Lucinda; Seay, Amanda N.; Montero, Cindy; Barnes, Leslie L.; Vincent, Kevin R.; Conrad, Bryan P.; Chen, Cong; Vincent, Heather K.
2017-01-01
Objective To examine whether runners recovering from a lower body musculoskeletal injury have different metabolic, cardiopulmonary, and gait responses compared with healthy runners. Design Cross-sectional study. Setting Research laboratory at an academic institution. Methods Healthy runners (n = 50) were compared with runners who were recently injured but had returned to running (n = 50). Both groups were participating in similar cross-training modalities such as swimming, weight training, biking, and yoga. Running gait was analyzed on a treadmill using 3-dimensional motion capture, and metabolic and cardiopulmonary measures were captured simultaneously with a portable metabolic analyzer. Main Outcome Measures Rate of oxygen consumption, heart rate, ventilation, carbohydrate and fat oxidation values, gait temporospatial parameters and range of motion measures (ROM) in the sagittal plane, energy expenditure, and vertical displacement of the body’s center of gravity (COG). Results The self-selected running speed was different between the injured and healthy runners (9.7 ± 1.1 km/h and 10.6 ± 1.1 km/h, respectively; P = .038). No significant group differences were noted in any metabolic or cardiopulmonary variable while running at the self-selected or standard speed (13.6 km/h). The vertical displacement of the COG was less in the injured group (8.4 ± 1.4 cm and 8.9 ± 1.4, respectively; P = .044). ROM about the right ankle in the sagittal plane at the self-selected running speed during the gait cycle was less in the injured runners compared with the healthy runners (P < .05). Conclusions Runners with a recent lower body injury who have returned to running have similar cardiopulmonary and metabolic responses to running as healthy runners at the self-selected and standard speeds; this finding may be due in part to participation in cross-training modes that preserve cardiopulmonary and metabolic adaptations. Injured runners may conserve motion by minimizing COG displacement and ankle joint ROM during a gait cycle. PMID:24998402
Głąbska, Dominika; Jusińska, Marta
2018-01-01
Properly balanced diet is especially important in the case of young athletes, as it influences not only their physical development, but also influences results obtained during trainings and competitions. The aim of the study was to assess the choice of food products and the energy value of diets of female middleand long-distance runners, depending on the self-assessment of their nutritional habits. The study was conducted in the group of 40 female middle- and long-distance runners, aged 15-25, who declared average diet (n=15, 37.5%) or outstanding diet (n=25, 62.5%). Participants conducted three-day dietary record of the consumed dishes and drunk beverages, that was based on the self-reported data. The choice of products, the energy value of diets as well as macronutrients intake were compared depending on the self-assessment of the nutritional habits. Runners declaring outstanding diet were characterized by significantly lower intake of dairy beverages, than runners declaring average diet (p=0.0459), but simultaneously, by higher intake of mushrooms (p=0.0453). No difference of energy value of diets was stated between groups of runners depending on the self-assessment of their nutritional habits. Runners declaring outstanding diet were characterized by significantly lower intake of lactose, than runners declaring average diet (p=0.0119), but simultaneously, by higher intake of cholesterol (p=0.0307). The female middle- and long-distance runners analysed in the presented study do not assess the quality of their diet reliably, so they probably do not have the sufficient nutritional knowledge. There is a need to implement nutritional education among professional runners and their coaches, in order to improve the quality of diet of professional runners and, as a results maybe also to improve their sport results.
Cost of enlarged operating zone for an existing Francis runner
NASA Astrophysics Data System (ADS)
Monette, Christine; Marmont, Hugues; Chamberland-Lauzon, Joël; Skagerstrand, Anders; Coutu, André; Carlevi, Jens
2016-11-01
Traditionally, hydro power plants have been operated close to best efficiency point, the more stable operating condition for which they have been designed. However, because of changes in the electricity market, many hydro power plants operators wish to operate their machines differently to fulfil those new market needs. New operating conditions can include whole range operation, many start/stops, extensive low load operation, synchronous condenser mode and power/frequency regulation. Many of these new operating conditions may impose more severe fatigue damage than the traditional base load operation close to best efficiency point. Under these conditions, the fatigue life of the runner may be significantly reduced and reparation or replacement cost might occur sooner than expected. In order to design reliable Francis runners for those new challenging operating scenarios, Andritz Hydro has developed various proprietary tools and design rules. These are used within Andritz Hydro to design mechanically robust Francis runners for the operating scenarios fulfilling customer's specifications. To estimate residual life under different operating scenarios of an existing runner designed years ago for best efficiency base load operation, Andritz Hydro's design rules and tools would necessarily lead to conservative results. While the geometry of a new runner can be modified to fulfil all conservative mechanical design rules, the predicted fatigue life of an existing runner under off-design operating conditions may appear rather short because of the conservative safety factor included in the calculations. The most precise and reliable way to calculate residual life of an existing runner under different operating scenarios is to perform a strain gauge measurement campaign on the runner. This paper presents the runner strain gage measurement campaign of a mid-head Francis turbine over all the operating conditions available during the test, the analysis of the measurement signals and the runner residual life assessment under different operating scenarios. With these results, the maintenance cost of the change in operating mode can then be calculated and foreseen by the power plant owner.
Lower limb dynamics vary in shod runners who acutely transition to barefoot running.
Hashish, Rami; Samarawickrame, Sachithra D; Powers, Christopher M; Salem, George J
2016-01-25
Relative to traditional shod rear-foot strike (RFS) running, habituated barefoot running is associated with a forefoot-strike (FFS) and lower loading rates. Accordingly, barefoot running has been purported to reduce lower-extremity injury risk. Investigations, however, indicate that novice barefoot runners may not innately adopt a FFS. Therefore, the purpose of this study was to examine lower-extremity dynamics of habitually shod runners who acutely transition to barefoot running. 22 recreational RFS runners were included in this investigation. This laboratory controlled study consisted of two visits one-week apart, examining habitually shod, then novice barefoot running. Foot-strike patterns and loading rates were determined using motion analysis and force plates, and joint energy absorption was calculated using inverse dynamics. Of the 22 runners, 8 maintained a RFS, 9 adopted a MFS, and 5 adopted a FFS during novice barefoot running. All runners demonstrated a reduction in knee energy absorption when running barefoot; MFS and FFS runners also demonstrated a significant increase in ankle energy absorption. Runners who maintained a RFS presented with loading rates significantly higher than traditional shoe running, whereas FFS runners demonstrated a significant reduction in loading rate. Mid-foot strikers did not demonstrate a significant change in loading rate. These results indicate that habitually shod RFS runners demonstrate a variety of foot-strike and lower-extremity dynamic responses during the acute transition to barefoot running. Accordingly, explicit instruction regarding foot-strike patterns may be necessary if transitioning to barefoot. Long-term prospective studies are required in order to determine the influence of FFS barefoot running on injury rates. Copyright © 2015 Elsevier Ltd. All rights reserved.
A case study of the fluid structure interaction of a Francis turbine
NASA Astrophysics Data System (ADS)
Müller, C.; Staubli, T.; Baumann, R.; Casartelli, E.
2014-03-01
The Francis turbine runners of the Grimsel 2 pump storage power plant showed repeatedly cracks during the last decade. It is assumed that these cracks were caused by flow induced forces acting on blades and eventual resonant runner vibrations lead to high stresses in the blade root areas. The eigenfrequencies of the runner were simulated in water using acoustic elements and compared to experimental data. Unsteady blades pressure distribution determined by a transient CFD simulation of the turbine were coupled to a FEM simulation. The FEM simulation enabled analyzing the stresses in the runner and the eigenmodes of the runner vibrations. For a part-load operating point, transient CFD simulations of the entire turbine, including the spiral case, the runner and the draft tube were carried out. The most significant loads on the turbine runner resulted from the centrifugal forces and the fluid forces. Such forces effect temporally invariant runner blades loads, in contrast rotor stator interaction or draft tube instabilities induce pressure fluctuations which cause the temporally variable forces. The blades pressure distribution resulting from the flow simulation was coupled by unidirectional-harmonic FEM simulation. The dominant transient blade pressure distribution of the CFD simulation were Fourier transformed, and the static and harmonic portion assigned to the blade surfaces in the FEM model. The evaluation of the FEM simulation showed that the simulated part load operating point do not cause critical stress peaks in the crack zones. The pressure amplitudes and frequencies are very small and interact only locally with the runner blades. As the frequencies are far below the modal frequencies of the turbine runner, resonant vibrations obviously are not excited.
Predicting plantar fasciitis in runners.
Warren, B L; Jones, C J
1987-02-01
Ninety-one runners were studied to determine whether specific variables were indicative of runners who had suffered with plantar fasciitis either presently or formerly vs runners who had never suffered with plantar fasciitis. Each runner was asked to complete a running history, was subjected to several anatomical measurements, and was asked to run on a treadmill in both a barefoot and shoe condition at a speed of 3.35 mps (8 min mile pace). Factor coefficients were used in a discriminant function analysis which revealed that, when group membership was predicted, 63% of the runners could be correctly assigned to their group. Considering that 76% of the control group was correctly predicted, it was concluded that the predictor variables were able to correctly predict membership of the control group, but not able to correctly predict the presently or formerly injured sufferers of plantar fasciitis.
Prescribed and self-reported seasonal training of distance runners.
Hewson, D J; Hopkins, W G
1995-12-01
A survey of 123 distance-running coaches and their best runners was undertaken to describe prescribed seasonal training and its relationship to the performance and self-reported training of the runners. The runners were 43 females and 80 males, aged 24 +/- 8 years (mean +/- S.D.), training for events from 800 m to the marathon, with seasonal best paces of 86 +/- 6% of sex- and age-group world records. The coaches and runners completed a questionnaire on typical weekly volumes of interval and strength training, and typical weekly volumes and paces of moderate and hard continuous running, for build-up, pre-competition, competition and post-competition phases of a season. Prescribed training decreased in volume and increased in intensity from the build-up through to the competition phase, and had similarities with 'long slow distance' training. Coaches of the faster runners prescribed longer build-ups, greater volumes of moderate continuous running and slower relative paces of continuous running (r = 0.19-0.36, P < 0.05), suggesting beneficial effects of not training close to competition pace. The mean training volumes and paces prescribed by the coaches were similar to those reported by the runners, but the correlations between prescribed and reported training were poor (r = 0.2-0.6). Coaches may therefore need to monitor their runners' training more closely.
Running economy and body composition between competitive and recreational level distance runners.
Mooses, Martin; Jürimäe, J; Mäestu, J; Mooses, K; Purge, P; Jürimäe, T
2013-09-01
The aim of the present study was to compare running economy between competitive and recreational level athletes at their individual ventilatory thresholds on track and to compare body composition parameters that are related to the individual running economy measured on track. We performed a cross-sectional analysis of a total 45 male runners classified as competitive runners (CR; n = 28) and recreational runners (RR; n = 17). All runners performed an incremental test on treadmill until voluntary exhaustion and at least 48 h later a 2 × 2000 m test at indoor track with intensities according to ventilatory threshold 1, ventilator threshold 2. During the running tests, athletes wore portable oxygen analyzer. Body composition was measured with Dual energy X-ray absorptiometry (DXA) method. Running economy at the first ventilatory threshold was not significantly related to any of the measured body composition values or leg mass ratios either in the competitive or in the recreational runners group. This study showed that there was no difference in the running economy between distance runners with different performance level when running on track, while there was a difference in the second ventilatory threshold speed in different groups of distance runners. Differences in running economy between competitive and recreational athletes cannot be explained by body composition and/or different leg mass ratios.
Potential Relationship between Passive Plantar Flexor Stiffness and Running Performance.
Ueno, Hiromasa; Suga, Tadashi; Takao, Kenji; Tanaka, Takahiro; Misaki, Jun; Miyake, Yuto; Nagano, Akinori; Isaka, Tadao
2018-02-01
The present study aimed to determine the relationship between passive stiffness of the plantar flexors and running performance in endurance runners. Forty-eight well-trained male endurance runners and 24 untrained male control subjects participated in this study. Plantar flexor stiffness during passive dorsiflexion was calculated from the slope of the linear portion of the torque-angle curve. Of the endurance runners included in the present study, running economy in 28 endurance runners was evaluated by measuring energy cost during three 4-min trials (14, 16, and 18 km/h) of submaximal treadmill running. Passive stiffness of the plantar flexors was significantly higher in endurance runners than in untrained subjects. Moreover, passive plantar flexor stiffness in endurance runners was significantly correlated with a personal best 5000-m race time. Furthermore, passive plantar flexor stiffness in endurance runners was significantly correlated with energy cost during submaximal running at 16 km/h and 18 km/h, and a trend towards such significance was observed at 14 km/h. The present findings suggest that stiffer plantar flexors may help achieve better running performance, with greater running economy, in endurance runners. Therefore, in the clinical setting, passive stiffness of the plantar flexors may be a potential parameter for assessing running performance. © Georg Thieme Verlag KG Stuttgart · New York.
Valentín, David; Presas, Alexandre; Bossio, Matias; Egusquiza, Mònica; Egusquiza, Eduard; Valero, Carme
2018-01-10
Nowadays, hydropower plays an essential role in the energy market. Due to their fast response and regulation capacity, hydraulic turbines operate at off-design conditions with a high number of starts and stops. In this situation, dynamic loads and stresses over the structure are high, registering some failures over time, especially in the runner. Therefore, it is important to know the dynamic response of the runner while in operation, i.e., the natural frequencies, damping and mode shapes, in order to avoid resonance and fatigue problems. Detecting the natural frequencies of hydraulic turbine runners while in operation is challenging, because they are inaccessible structures strongly affected by their confinement in water. Strain gauges are used to measure the stresses of hydraulic turbine runners in operation during commissioning. However, in this paper, the feasibility of using them to detect the natural frequencies of hydraulic turbines runners while in operation is studied. For this purpose, a large Francis turbine runner (444 MW) was instrumented with several strain gauges at different positions. First, a complete experimental strain modal testing (SMT) of the runner in air was performed using the strain gauges and accelerometers. Then, the natural frequencies of the runner were estimated during operation by means of analyzing accurately transient events or rough operating conditions.
Presas, Alexandre; Bossio, Matias; Egusquiza, Eduard; Valero, Carme
2018-01-01
Nowadays, hydropower plays an essential role in the energy market. Due to their fast response and regulation capacity, hydraulic turbines operate at off-design conditions with a high number of starts and stops. In this situation, dynamic loads and stresses over the structure are high, registering some failures over time, especially in the runner. Therefore, it is important to know the dynamic response of the runner while in operation, i.e., the natural frequencies, damping and mode shapes, in order to avoid resonance and fatigue problems. Detecting the natural frequencies of hydraulic turbine runners while in operation is challenging, because they are inaccessible structures strongly affected by their confinement in water. Strain gauges are used to measure the stresses of hydraulic turbine runners in operation during commissioning. However, in this paper, the feasibility of using them to detect the natural frequencies of hydraulic turbines runners while in operation is studied. For this purpose, a large Francis turbine runner (444 MW) was instrumented with several strain gauges at different positions. First, a complete experimental strain modal testing (SMT) of the runner in air was performed using the strain gauges and accelerometers. Then, the natural frequencies of the runner were estimated during operation by means of analyzing accurately transient events or rough operating conditions. PMID:29320422
Reid, Stephen A; King, M Jonathan
2007-07-01
To determine if exercise-associated hyponatremia (EAH) was a cause of morbidity among runners requiring medical care at an Australian mountain ultramarathon. Case series. Six Foot Track mountain ultramarathon, New South Wales, Australia, March 2006. Runners presenting to the medical facility. Serum biochemistry. No cases of exercise-associated hyponatremia were identified among 9 athletes (from 775 starters) who were treated with intravenous fluid therapy. Unwell runners had a mean serum (Na) of 143 mmol/L (range 138-147 mmol/L). All runners tested had elevated serum urea and creatinine concentrations. In this setting, EAH was not a significant cause of morbidity.
Kowalski, Erik; Li, Jing Xian
2016-11-01
This study investigated the normal and parallel ground reaction forces during downhill and uphill running in habitual forefoot strike and habitual rearfoot strike (RFS) runners. Fifteen habitual forefoot strike and 15 habitual RFS recreational male runners ran at 3 m/s ± 5% during level, uphill and downhill overground running on a ramp mounted at 6° and 9°. Results showed that forefoot strike runners had no visible impact peak in all running conditions, while the impact peaks only decreased during the uphill conditions in RFS runners. Active peaks decreased during the downhill conditions in forefoot strike runners while active loading rates increased during downhill conditions in RFS runners. Compared to the level condition, parallel braking peaks were larger during downhill conditions and parallel propulsive peaks were larger during uphill conditions. Combined with previous biomechanics studies, our findings suggest that forefoot strike running may be an effective strategy to reduce impacts, especially during downhill running. These findings may have further implications towards injury management and prevention.
Effects of foot orthoses on Achilles tendon load in recreational runners.
Sinclair, J; Isherwood, J; Taylor, P J
2014-09-01
Achilles tendon pathology is a frequently occurring musculoskeletal disorder in runners. Foot orthoses have been shown to reduce the symptoms of pain in runners but their mechanical effects are still not well understood. This study aimed to examine differences in Achilles tendon load when running with and without orthotic intervention. Twelve male runners ran at 4.0 m·s(-1). Ankle joint moments and Achilles tendon forces were compared when running with and without orthotics. The results indicate that running with foot orthotics was associated with significant reductions in Achilles tendon load compared to without orthotics. In addition to providing insight into the mechanical effects of orthotics in runners, the current investigation suggests that via reductions in Achilles tendon load, foot orthoses may serve to reduce the incidence of chronic Achilles tendon pathologies in runners. Copyright © 2014 Elsevier Ltd. All rights reserved.
Hashish, Rami; Samarawickrame, Sachithra D; Sigward, Susan; Azen, Stanley P; Salem, George J
2018-01-01
Recent investigations have revealed lower vertical loading rates and knee energy absorption amongst experienced barefoot runners relative to those who rear-foot strike (RFS). Although this has led to an adoption of barefoot running amongst many recreational shoe runners, recent investigations indicate that the experienced barefoot pattern is not immediately realized. Therefore, the purpose this investigation was to quantify changes in lower-extremity dynamics and clinical outcomes measures for habitually shod runners who perform a transition to barefoot running. We examined lower-extremity dynamics and clinical outcomes for 26 RFS shod runners who performed an 8-10 week transition to barefoot running. Runners were evaluated at the University of Southern California's Musculoskeletal Biomechanics Research Laboratory. Foot-strike patterns, vertical load rates, and joint energetics were evaluated before and after the transition using inverse dynamics. Clinical assessments were conducted throughout the transition by two licensed clinicians. Eighteen of the 26 runners successfully completed the transition: 7 maintained a RFS, 8 adopted a mid-foot strike (MFS), and 3 adopted a forefoot strike (FFS) during novice barefoot running. Following the transition, novice MFS/FFS runners often demonstrated reversions in strike-patterns and associated reductions in ankle energetics. We report no change in loading rates and knee energy absorption across transition time points. Importantly, there were no adverse events other than transient pain and soreness. These findings indicate that runners do not innately adopt the biomechanical characteristics thought to lower injury risk in-response to an uninstructed barefoot running transition. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Huang, X.; Oram, C.; Sick, M.
2014-03-01
More efforts are put on hydro-power to balance voltage and frequency within seconds for primary control in modern smart grids. This requires hydraulic turbines to run at off-design conditions. especially at low load or speed-no load. Besides. the tendency of increasing power output and decreasing weight of the turbine runners has also led to the high level vibration problem of the runners. especially high head Francis runners. Therefore. it is important to carry out the static and dynamic stress analyses of prototype high head Francis runners. This paper investigates the static and dynamic stresses on the prototype high head Francis runner based on site measurements and numerical simulations. The site measurements are performed with pressure transducers and strain gauges. Based on the measured results. computational fluid dynamics (CFD) simulations for the flow channel from stay vane to draft tube cone are performed. Static pressure distributions and dynamic pressure pulsations caused by rotor-stator interaction (RSI) are obtained under various operating conditions. With the CFD results. static and dynamic stresses on the runner at different operating points are calculated by means of the finite element method (FEM). The agreement between simulation and measurement is analysed with linear regression method. which indicates that the numerical result agrees well with that of measurement. Furthermore. the maximum static and dynamic stresses on the runner blade are obtained at various operating points. The relations of the maximum stresses and the power output are discussed in detail. The influences of the boundary conditions on the structural behaviour of the runner are also discussed.
A study of serum sodium level among Hong Kong runners.
Au-Yeung, Kwan Leong; Wu, Wing Cheung; Yau, Wah Hon; Ho, Hiu Fai
2010-11-01
Hyponatremia and the associated life-threatening complications have emerged as an important issue among marathon runners. This study was conducted to estimate the serum sodium level among local marathon runners and to identify the associated risk factors of dysnatremia. Prospective observational cohort study. Hong Kong Marathon 2008. Subjects were approached at their convenience to participate in the study. Only full-marathon runners were recruited. They were to have had an unremarkable medical and drug history. Demographic data, training information, previous marathon experience, anticipated drinking strategy, details of fluid consumption throughout the race, weight change, finishing time, and physical complaint. Post-race serum sodium level. Of the 6488 entries to the race, 370 runners (5.7%) were recruited. Among them, 272 (73.5%) completed the race and attended for blood sampling and data collection. One runner (0.4%) had hyponatremia (133 mmol/L) and 35 runners (12.9%) had hypernatremia (>145 mmol/L), whereas 236 runners (86.7%) had normal serum sodium (135-145 mmol/L) after the race. No symptomatic dysnatremia was found. A mean weight reduction of 0.70 kg was found after the race. An average of 1.9 L of fluid was consumed during the race and 2.5 L if the fluid consumed immediately before and after the race was also included. Hypernatremia was seen in runners who were better trained before the race, those who performed better, and those who drank less water after the race. This is the largest prospective observational cohort study of dysnatremia conducted on athletes completing a standard marathon in Asia. No case of symptomatic dysnatremia was found.
Intrinsic foot muscle volume in experienced runners with and without chronic plantar fasciitis.
Cheung, R T H; Sze, L K Y; Mok, N W; Ng, G Y F
2016-09-01
Plantar fasciitis, a common injury in runners, has been speculated to be associated with weakness of the intrinsic foot muscles. A recent study reported that atrophy of the intrinsic forefoot muscles might contribute to plantar fasciitis by destabilizing the medial longitudinal arch. However, intrinsic foot muscle volume difference between individuals with plantar fasciitis and healthy counterparts remains unknown. This study examined the relationship of intrinsic foot muscle volume and incidence of plantar fasciitis. Case-control study. 20 experienced (≥5 years) runners were recruited. Ten of them had bilateral chronic (≥2 years) plantar fasciitis while the others were healthy characteristics-matched runners. Intrinsic muscle volumes of the participants' right foot were scanned with a 1.5T magnetic resonance system and segmented using established methods. Body-mass normalized intrinsic foot muscle volumes were compared between runners with and without chronic plantar fasciitis. There was significant greater rearfoot intrinsic muscle volume in healthy runners than runners with chronic plantar fasciitis (Cohen's d=1.13; p=0.023). A similar trend was also observed in the total intrinsic foot muscle volume but it did not reach a statistical significance (Cohen's d=0.92; p=0.056). Forefoot volume was similar between runners with and without plantar fasciitis. These results suggest that atrophy of intrinsic foot muscles may be associated with symptoms of plantar fasciitis in runners. These findings may provide useful information in rehabilitation strategies of chronic plantar fasciitis. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Runner's Knee: What is it and How Effective is Conservative Management?
ERIC Educational Resources Information Center
Pretorius, Deirdre M.; And Others
1986-01-01
Forty-eight runners with runner's knee were examined, treated, and studied for 8 months to identify the causes of this injury and its response to a particular regimen of conservative management. Results are discussed. (Author/DF)
Beig, Mirza I; Callister, Robin; Saint, David A; Bondarenko, Eugene; Walker, Frederick R; Day, Trevor A; Nalivaiko, Eugene
2011-01-01
1. It is currently unknown whether long-term voluntary exercise has enduring cardioprotective effects in animal models. 2. The present study was conducted in three groups of rats: (i) sedentary controls (n = 6); (ii) 24 h runners (n = 8; unlimited access to running wheels); and (iii) 2 h runners (n = 8; access to running wheels limited to 2 h daily). After termination of the 6 week exercise protocol, all rats were implanted with the telemetric electrocardiogram transmitters and were studied 1 week later. 3. Resting heart rate (HR) values in the control rats, 24 h runners and 2 h runners were 372 ± 7, 361 ± 9 and 298 ± 5 b.p.m., respectively (P < 0.05 for 2 h runners vs controls). The high-frequency spectral power in the control rats, 24 h runners and 2 h runners was 3.9 ± 0.2, 4.3 ± 0.3 and 5.3 ± 0.3 s², respectively (P < 0.05 for 2 h runners vs controls), whereas intrinsic HR was 383 ± 3, 377 ± 2 and 346 ± 3 b.p.m., respectively (P < 0.001 for 2 h runners vs controls). Restraint stress provoked tachycardia of similar magnitude in all groups. 4. After completion of telemetric studies, haemodynamic indices and susceptibility to cardiac arrhythmias were assessed in anaesthetized animals, there were no major between-group differences in HR, arterial pressure, contractility indices or sensitivity to β-adrenoceptor stimulation (dobutamine) or blockade (atenolol). The effective refractory period in the control rats, 24 h runners and 2 h runners was 49 ± 2, 55 ± 2 and 60 ± 4 ms, respectively (P = 0.054 for 2 h runners vs controls). A significantly higher dose of aconitine was required to provoke ventricular arrhythmias in the 24 h and 2 h running groups compared with controls (489 ± 76, 505 ± 88 and 173 ± 33 μg, respectively; P < 0.05). 5. We conclude that, in rats, long-term voluntary exercise has enduring cardioprotective effects mediated at the level of both the central nervous system and the heart. © 2010 The Authors. Clinical and Experimental Pharmacology and Physiology © 2010 Blackwell Publishing Asia Pty Ltd.
Study on an undershot cross-flow water turbine
NASA Astrophysics Data System (ADS)
Nishi, Yasuyuki; Inagaki, Terumi; Li, Yanrong; Omiya, Ryota; Fukutomi, Junichiro
2014-06-01
This study aims to develop a water turbine suitable for ultra-low heads in open channels, with the end goal being the effective utilization of unutilized hydroelectric energy in agricultural water channels. We performed tests by applying a cross-flow runner to an open channel as an undershot water turbine while attempting to simplify the structure and eliminate the casing. We experimentally investigated the flow fields and performance of water turbines in states where the flow rate was constant for the undershot cross-flow water turbine mentioned above. In addition, we compared existing undershot water turbines with our undershot cross-flow water turbine after attaching a bottom plate to the runner. From the results, we were able to clarify the following. Although the effective head for cross-flow runners with no bottom plate was lower than those found in existing runners equipped with a bottom plate, the power output is greater in the high rotational speed range because of the high turbine efficiency. Also, the runner with no bottom plate differed from runners that had a bottom plate in that no water was being wound up by the blades or retained between the blades, and the former received twice the flow due to the flow-through effect. As a result, the turbine efficiency was greater for runners with no bottom plate in the full rotational speed range compared with that found in runners that had a bottom plate.
Mikkelsson, L; Kaprio, J; Kautiainen, H; Nupponen, H; Tikkanen, M J; Kujala, U M
2005-01-01
The aim was to study whether aerobic fitness measured by a maximal endurance running test at adolescence predicts prevalence of hypertension or blood pressure levels in adulthood. From the 413 (197 slow runners and 216 fast runners) participating in a 2000-meter running test at adolescence in 1976 and responding to a health and fitness questionnaire in 2001, 29 subjects (15 very slow runners and 14 very fast runners) participated in a clinical follow-up study in 2001. Compared to those who were fast runners in adolescence, those who were slow runners tended to have higher age-adjusted risk of hypertension at follow-up (OR 2.7, 95 % CI 0.9 to 7.5; p=0.07). The result persisted after further adjustment for body mass index at follow-up (OR 2.9, 95 % CI 1.0 to 8.3; p=0.05). Diastolic blood pressure was higher for very slow runners at adolescence compared to very fast runners, the age-adjusted mean diastolic blood pressure being 90 mm Hg (95 % CI 86 to 93) vs. 83 mm Hg (95 % CI 80 to 87), age-adjusted p=0.013. High endurance type fitness in adolescence predicts low risk of hypertension and low resting diastolic blood pressure levels in adult men.
The Preferred Movement Path Paradigm: Influence of Running Shoes on Joint Movement.
Nigg, Benno M; Vienneau, Jordyn; Smith, Aimée C; Trudeau, Matthieu B; Mohr, Maurice; Nigg, Sandro R
2017-08-01
(A) To quantify differences in lower extremity joint kinematics for groups of runners subjected to different running footwear conditions, and (B) to quantify differences in lower extremity joint kinematics on an individual basis for runners subjected to different running footwear conditions. Three-dimensional ankle and knee joint kinematics were collected for 35 heel-toe runners when wearing three different running shoes and when running barefoot. Absolute mean differences in ankle and knee joint kinematics were computed between running shoe conditions. The percentage of individual runners who displayed differences below a 2°, 3°, and 5° threshold were also calculated. The results indicate that the mean kinematics of the ankle and knee joints were similar between running shoe conditions. Aside from ankle dorsiflexion and knee flexion, the percentage of runners maintaining their movement path between running shoes (i.e., less than 3°) was in the order of magnitude of about 80% to 100%. Many runners showed ankle and knee joint kinematics that differed between a conventional running shoe and barefoot by more than 3°, especially for ankle dorsiflexion and knee flexion. Many runners stay in the same movement path (the preferred movement path) when running in various different footwear conditions. The percentage of runners maintaining their preferred movement path depends on the magnitude of the change introduced by the footwear condition.
The Effects of a Transition to Minimalist Shoe Running on Intrinsic Foot Muscle Size.
Johnson, A W; Myrer, J W; Mitchell, U H; Hunter, I; Ridge, S T
2016-02-01
A proposed benefit of minimalist shoe running is an increase in intrinsic foot muscle strength. This study examined change in intrinsic foot muscle size in runners transitioning to Vibram FiveFingers™ minimalist shoes compared to a control group running in traditional running shoes. We compare pre-transition size between runners who developed bone marrow edema to those who did not. 37 runners were randomly assigned to the Vibram FiveFingers™ group (n=18) or control group (n=19). Runners' bone marrow edema and intrinsic foot muscle size were measured at baseline and after 10 weeks. Total running volume was maintained by all runners. A significant increase in abductor hallucis cross-sectional area of 10.6% occurred in the Vibram FiveFingers™ group compared to the control group (p=0.01). There was no significant change in any of the other muscles examined (p>0.05). 8 of the Vibram FiveFingers™ runners, and 1 control runner developed bone marrow edema. Those who developed bone marrow edema, primarily women, had significantly smaller size in all assessed muscles (p≤0.05). Size of intrinsic foot muscles appears to be important in safely transitioning to minimalist shoe running. Perhaps intrinsic foot muscle strengthening may benefit runners wanting to transition to minimalist shoes. © Georg Thieme Verlag KG Stuttgart · New York.
Fuller, Joel T; Thewlis, Dominic; Buckley, Jonathan D; Brown, Nicholas A T; Hamill, Joseph; Tsiros, Margarita D
2017-04-01
Minimalist shoes have been popularized as a safe alternative to conventional running shoes. However, a paucity of research is available investigating the longer-term safety of minimalist shoes. To compare running-related pain and injury between minimalist and conventional shoes in trained runners and to investigate interactions between shoe type, body mass, and weekly training distance. Randomized clinical trial; Level of evidence, 2. Sixty-one trained, habitual rearfoot footfall runners (mean ± SD: body mass, 74.6 ± 9.3 kg; weekly training distance, 25 ± 14 km) were randomly allocated to either minimalist or conventional shoes. Runners gradually increased the time spent running in their allocated shoes over 26 weeks. Running-related pain intensity was measured weekly by use of 100-mm visual analog scales. Time to first running-related injury was also assessed. Interactions were found between shoe type and weekly training distance for weekly running-related pain; greater pain was experienced with minimalist shoes ( P < .05), and clinically meaningful increases (>10 mm) were noted when the weekly training distance was more than 35 km/wk. Eleven of 30 runners sustained an injury in conventional shoes compared with 16 of 31 runners in minimalist shoes (hazard ratio, 1.64; 95% confidence interval, 0.63-4.27; P = .31). A shoe × body mass interaction was found for time to first running-related injury ( P = .01). For runners using minimalist shoes, relative to runners using conventional shoes, the risk of sustaining an injury became more likely with increasing body mass above 71.4 kg, and the risk was moderately increased (hazard ratio, 2.00; 95% confidence interval, 1.10-3.66; P = .02) for runners using minimalist shoes who had a body mass of 85.7 kg. Runners should limit weekly training distance in minimalist shoes to avoid running-related pain. Heavier runners are at greater risk of injury when running in minimalist shoes. Registration: Australian New Zealand Clinical Trials Registry (ACTRN12613000642785).
Trabecular bone in the calcaneus of runners
Holt, Brigitte; Troy, Karen; Hamill, Joseph
2017-01-01
Trabecular bone of the human calcaneus is subjected to extreme repetitive forces during endurance running and should adapt in response to this strain. To assess possible bone functional adaptation in the posterior region of the calcaneus, we recruited forefoot-striking runners (n = 6), rearfoot-striking runners (n = 6), and non-runners (n = 6), all males aged 20–41 for this institutionally approved study. Foot strike pattern was confirmed for each runner using a motion capture system. We obtained high resolution peripheral computed tomography scans of the posterior calcaneus for both runners and non-runners. No statistically significant differences were found between runners and nonrunners or forefoot strikers and rearfoot strikers. Mean trabecular thickness and mineral density were greatest in forefoot runners with strong effect sizes (<0.80). Trabecular thickness was positively correlated with weekly running distance (r2 = 0.417, p<0.05) and years running (r2 = 0.339, p<0.05) and negatively correlated with age at onset of running (r2 = 0.515, p<0.01) Trabecular thickness, mineral density and bone volume ratio of nonrunners were highly correlated with body mass (r2 = 0.824, p<0.05) and nonrunners were significantly heavier than runners (p<0.05). Adjusting for body mass revealed significantly thicker trabeculae in the posterior calcaneus of forefoot strikers, likely an artifact of greater running volume and earlier onset of running in this subgroup; thus, individuals with the greatest summative loading stimulus had, after body mass adjustment, the thickest trabeculae. Further study with larger sample sizes is necessary to elucidate the role of footstrike on calcaneal trabecular structure. To our knowledge, intraspecific body mass correlations with measures of trabecular robusticity have not been reported elsewhere. We hypothesize that early adoption of running and years of sustained moderate volume running stimulate bone modeling in trabeculae of the posterior calcaneus. PMID:29141022
Trabecular bone in the calcaneus of runners.
Best, Andrew; Holt, Brigitte; Troy, Karen; Hamill, Joseph
2017-01-01
Trabecular bone of the human calcaneus is subjected to extreme repetitive forces during endurance running and should adapt in response to this strain. To assess possible bone functional adaptation in the posterior region of the calcaneus, we recruited forefoot-striking runners (n = 6), rearfoot-striking runners (n = 6), and non-runners (n = 6), all males aged 20-41 for this institutionally approved study. Foot strike pattern was confirmed for each runner using a motion capture system. We obtained high resolution peripheral computed tomography scans of the posterior calcaneus for both runners and non-runners. No statistically significant differences were found between runners and nonrunners or forefoot strikers and rearfoot strikers. Mean trabecular thickness and mineral density were greatest in forefoot runners with strong effect sizes (<0.80). Trabecular thickness was positively correlated with weekly running distance (r2 = 0.417, p<0.05) and years running (r2 = 0.339, p<0.05) and negatively correlated with age at onset of running (r2 = 0.515, p<0.01) Trabecular thickness, mineral density and bone volume ratio of nonrunners were highly correlated with body mass (r2 = 0.824, p<0.05) and nonrunners were significantly heavier than runners (p<0.05). Adjusting for body mass revealed significantly thicker trabeculae in the posterior calcaneus of forefoot strikers, likely an artifact of greater running volume and earlier onset of running in this subgroup; thus, individuals with the greatest summative loading stimulus had, after body mass adjustment, the thickest trabeculae. Further study with larger sample sizes is necessary to elucidate the role of footstrike on calcaneal trabecular structure. To our knowledge, intraspecific body mass correlations with measures of trabecular robusticity have not been reported elsewhere. We hypothesize that early adoption of running and years of sustained moderate volume running stimulate bone modeling in trabeculae of the posterior calcaneus.
Miller, Ross H; Meardon, Stacey A; Derrick, Timothy R; Gillette, Jason C
2008-08-01
Previous research has proposed that a lack of variability in lower extremity coupling during running is associated with pathology. The purpose of the study was to evaluate lower extremity coupling variability in runners with and without a history of iliotibial band syndrome (ITBS) during an exhaustive run. Sixteen runners ran to voluntary exhaustion on a motorized treadmill while a motion capture system recorded reflective marker locations. Eight runners had a history of ITBS. At the start and end of the run, continuous relative phase (CRP) angles and CRP variability between strides were calculated for key lower extremity kinematic couplings. The ITBS runners demonstrated less CRP variability than controls in several couplings between segments that have been associated with knee pain and ITBS symptoms, including tibia rotation-rearfoot motion and rearfoot motion-thigh ad/abduction, but more variability in knee flexion/extension-foot ad/abduction. The ITBS runners also demonstrated low variability at heel strike in coupling between rearfoot motion-tibia rotation. The results suggest that runners prone to ITBS use abnormal segmental coordination patterns, particular in couplings involving thigh ad/abduction and tibia internal/external rotation. Implications for variability in injury etiology are suggested.
Simulation of Surface Pressure Induced by Vortex/Body Interaction
NASA Astrophysics Data System (ADS)
He, M.; Islam, M.; Veitch, B.; Bose, N.; Colbourne, M. B.; Liu, P.
When a strong vortical wake impacts a structure, the pressure on the impacted surface sees large variations in its amplitude. This pressure fluctuation is one of the main sources causing severe structural vibration and hydrodynamic noise. Economical and effective prediction methods of the fluctuating pressure are required by engineers in many fields. This paper presents a wake impingement model (WIM) that has been incorporated into a panel method code, Propella, and its applications in simulations of a podded propeller wake impacting on a strut. Simulated strut surface pressure distributions and variations are compared with experimental data in terms of time-averaged components and phase-averaged components. The pressure comparisons show that the calculated results are in a good agreement with experimental data.
Lamon-Fava, S; Fisher, E C; Nelson, M E; Evans, W J; Millar, J S; Ordovas, J M; Schaefer, E J
1989-01-01
Habitual physical exercise has been reported to have beneficial effects on plasma lipoproteins. To examine this question in women, plasma cholesterol, triglyceride, and apolipoprotein (apo) A-I and B levels, and low density lipoprotein (LDL) particle size were determined in 25 women runners (9 of whom had exercise-related secondary amenorrhea) and 36 age-matched nonexercising women (controls). The eumenorrheic runners had significantly lower apo B levels and significantly greater mean apo A-I/apo B ratios and LDL particle sizes than did the control women (P less than 0.05). Lower apo B levels were correlated with decreased body mass index, a known exercise effect (P less than 0.0001). In addition, normally menstruating runners had cholesterol and triglyceride levels that were 7.6% and 25.4% lower, respectively, and apo A-I levels that were 6.4% higher than control women (P = NS). In amenorrheic runners all parameters were similar to values in control women, except that apo B levels were 20% lower (P less than 0.05). Amenorrheic runners had lower plasma apo A-I levels (13%) and significantly lower apo A-I/apo B ratios and estradiol levels than eumenorrheic runners, and serum estradiol values in the runners were correlated with apo A-I levels (P less than 0.01). These data indicate that the beneficial effects of strenuous exercise on plasma apo A-I levels and apo A-I/apo B ratios in women runners can be reversed by exercise-induced amenorrhea and decreased serum estradiol levels, and that women runners have lower apo B levels than nonexercising women, regardless of menstrual status.
Gait-cycle characteristics and running economy in elite Eritrean and European runners.
Santos-Concejero, Jordan; Oliván, Jesús; Maté-Muñoz, José L; Muniesa, Carlos; Montil, Marta; Tucker, Ross; Lucia, Alejandro
2015-04-01
This study aimed to determine whether biomechanical characteristics such as ground-contact time, swing time, and stride length and frequency contribute to the exceptional running economy of East African runners. Seventeen elite long-distance runners (9 Eritrean, 8 European) performed an incremental maximal running test and 3 submaximal running bouts at 17, 19, and 21 km/h. During the tests, gas-exchange parameters were measured to determine maximal oxygen uptake (VO2max) and running economy (RE). In addition, ground-contact time, swing time, stride length, and stride frequency were measured. The European runners had higher VO2max values than the Eritrean runners (77.2 ± 5.2 vs 73.5 ± 6.0 mL · kg-1 · min-1, P = .011, effect sizes [ES] = 0.65), although Eritrean runners were more economical at 19 km/h (191.4 ± 10.4 vs 205.9 ± 13.3 mL · kg-1 · min-1, P = .026, ES = 1.21). There were no differences between groups for ground-contact time, swing time, stride length, or stride frequency at any speed. Swing time was associated with running economy at 21 km/h in the Eritrean runners (r = .71, P = .033), but no other significant association was found between RE and biomechanical variables. Finally, best 10-km performance was significantly correlated with RE (r = -.57; P = .013). Eritrean runners have superior RE compared with elite European runners. This appears to offset their inferior VO2max. However, the current data suggest that their better RE does not have a biomechanical basis. Other factors, not measured in the current study, may contribute to this RE advantage.
Ogwumike, Omoyemi O; Adeniyi, Ade F
2013-04-15
The growing interest in marathon runners and marathons in Nigeria has not been reflected in reports of injuries and other health problems associated with these events. This study therefore outlines the incidence of injuries, marathon-related health problems and delivery of physiotherapy at the maiden and second editions of the Splash 105.5 FM/ICPC Integrity Marathon in Ibadan city, south-west Nigeria in 2009 and 2010. Using a data entry sheet, demographics and information on running experience, past and present injuries and other health problems reported en route and at the finish line by the runners were documented. The prevalence of injuries and other health problems reported by previous and first-time runners were compared. In both events, 16.3% and 17.2% of the runners respectively reported injuries with significant occurrence in first-time runners (p = 0.003 for 2009; p = 0.002 for 2010) mostly at the finish line. The reported injury type and site were muscle cramps and the thigh (39.7% and 76.4% respectively). Heat exhaustion was reported by 42.8% of runners in 2009 and 56.3% in 2010. Cryotherapy was mostly used in combination with other physiotherapy modalities in both years. Most of the injuries and other health problems were reported by first-time marathon runners mainly at the finish line. The most reported site of injury was the thigh while muscle cramps and heat exhaustions were the most reported types of injuries and health problems. First-time marathon runners should be adequately informed of the predisposition to injury during marathons and adequate body conditioning should be emphasized. Ample preparation and effective involvement of the physiotherapy team is essential for management of injured runners en route and at the finish line in a marathon.
Health Culture and Running: Non-Elite Runners' Understandings of Doping and Supplementation.
Henning, April D
2015-01-01
Participants at the non-elite level of road running often take up the sport for purposes of health, as a way of taking responsibility for their own well-being. Often, these runners use dietary supplements as a way to improve health and to potentially enhance running performance. Supplements are distinct from banned performance enhancing drugs (PEDs), as they are legal and widely available, though very loosely regulated. Research demonstrates that the line between supplements and banned PEDs is increasingly blurry as cases of cross-contaminated and mislabeled supplements continue to be found. Such products may pose health risks to unsuspecting consumers. Despite anti-doping agencies' warnings to elite runners about these risks, non-elite runners are rarely told by any sport or anti-doping body to be wary of supplements. They are, however, inundated with media coverage of doping scandals usually involving only a few of the substances banned in sport. In short, these runners are often left to navigate supplement use on their own and many conflate supplement availability with safety. This article explores these routine dietary supplement practices among non-elite runners. Drawing from interviews with 28 non-elite runners in New York City, I discuss the perceptions and understandings of doping and dietary supplement use within the context of health culture. Interview data reveal that the social acceptance of dietary supplements and their widespread use among the broader public reinforce the notion among non-elite runners that such products are objectively safe and healthy. I argue that based on their assumptions of supplement safety, non-elite runners view dietary supplements as distinctly different from PEDs and that this difference encourages their use as health and performance aids.
Fatigue analyses of the prototype Francis runners based on site measurements and simulations
NASA Astrophysics Data System (ADS)
Huang, X.; Chamberland-Lauzon, J.; Oram, C.; Klopfer, A.; Ruchonnet, N.
2014-03-01
With the increasing development of solar power and wind power which give an unstable output to the electrical grid, hydropower is required to give a rapid and flexible compensation, and the hydraulic turbines have to operate at off-design conditions frequently. Prototype Francis runners suffer from strong vibrations induced by high pressure pulsations at part load, low part load, speed-no-load and during start-stops and load rejections. Fatigue and damage may be caused by the alternating stress on the runner blades. Therefore, it becomes increasingly important to carry out fatigue analysis and life time assessment of the prototype Francis runners, especially at off-design conditions. This paper presents the fatigue analyses of the prototype Francis runners based on the strain gauge site measurements and numerical simulations. In the case of low part load, speed-no-load and transient events, since the Francis runners are subjected to complex hydraulic loading, which shows a stochastic characteristic, the rainflow counting method is used to obtain the number of cycles for various dynamic amplitude ranges. From middle load to full load, pressure pulsations caused by Rotor-stator- Interaction become the dominant hydraulic excitation of the runners. Forced response analysis is performed to calculate the maximum dynamic stress. The agreement between numerical and experimental stresses is evaluated using linear regression method. Taking into account the effect of the static stress on the S-N curve, the Miner's rule, a linear cumulative fatigue damage theory, is employed to calculate the damage factors of the prototype Francis runners at various operating conditions. The relative damage factors of the runners at different operating points are compared and discussed in detail.
Running Mechanics and Variability with Aging.
Silvernail, Julia Freedman; Boyer, Katherine; Rohr, Eric; Brüggemann, Gert-Peter; Hamill, Joseph
2015-10-01
As the elderly population in the United States continues to grow, issues related to maintenance of health become increasingly important. Physical activity has positive benefits for healthy aging. Running, a popular form of exercise, is associated with the risk of developing injury, especially in older runners. Initial differences between older and younger runners have been observed, but these were observed without consideration of other differences between groups, such as running mileage. This study aims to compare running mechanics and lower-extremity coordination variability in matched groups of healthy younger and healthy older runners. Three-dimensional kinetics and kinematics were collected while 14 older adults (45-65 yr) and younger adults (18-35 yr) ran overground at 3.5 m·s. Knee, ankle, and hip joint angles and moments were determined. Discrete measures at foot strike (maximum and minimum) were determined and compared between groups. Segment angles during stance were utilized to calculate segment coordination variability between pelvis and thigh, thigh and shank, and shank and foot, using a modified vector coding technique. Knee and ankle joint angles were similar between groups (P > 0.05). Older runners had greater hip range of motion (P = 0.01) and peak hip flexion (P = 0.001) at a more extended hip position than younger runners. Older runners had smaller ankle plantarflexion moment (P = 0.04) and hip rotational moment (P = 0.005) than younger runners. There were no between-group differences in any of the variability measures (P > 0.05). Runners appear to maintain movement patterns and variability during running with increasing age, indicating that running itself may be contributing to maintenance of health among older runners in the current study.
Gordon, Leigh; Schwellnus, Martin; Swanevelder, Sonja; Jordaan, Esme; Derman, Wayne
2017-09-01
There are limited data on the negative effects of exercise in athletes with acute infective illness. The aim of this study was to determine whether a recently diagnosed prerace acute illness in runners affects the ability to finish a race. Runners were prospectively evaluated in the 3 days before the race for acute infective illness and then received participation advice using clinical criteria based on systemic or localised symptoms/signs. We compared the did-not-start and the did-not-finish frequencies of ill runners (Ill=172: localised=58.7%; systemic=41.3%) with that of a control group of runners (Con=53 734). Runners with a systemic illness were 10.4% more likely not to start compared with controls (29.6% vs 19.2%) (p=0.0073). The risk difference of not starting the race in runners who were advised not to run the race compared with controls was 37.3% (56.5% vs 19.2%, p<0.0001). Compared with controls, runners with illness had a significantly (p<0.05) greater risk (any illness (5.2% vs 1.6%), systemic illness (8.0% vs 1.6%), illness <24 hours before the race (11.1% vs 1.6%)) and relative risk (prevalence risk ratio) (any illness=3.4, systemic illness=4.9, systemic illness <24 hours before the race=7.0) of not finishing the race. Runners with prerace acute systemic illness, and particularly those diagnosed <24 hours before race day, are less likely to finish the race, indicating a reduction in race performance. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Ground reaction forces and kinematics in distance running in older-aged men.
Bus, Sicco A
2003-07-01
The biomechanics of distance running has not been studied before in older-aged runners but may be different than in younger-aged runners because of musculoskeletal degeneration at older age. This study aimed at determining whether the stance phase kinematics and ground reaction forces in running are different between younger- and older-aged men. Lower-extremity kinematics using three-dimensional motion analysis and ground reaction forces (GRF) using a force plate were assessed in 16 older-aged (55-65 yr) and 13 younger-aged (20-35 yr) well-trained male distance runners running at a self-selected (SRS) and a controlled (CRS) speed of 3.3 m.s-1. The older subjects ran at significantly lower self-selected speeds than the younger subjects (mean 3.34 vs 3.77 m.s-1). In both speed conditions, the older runners exhibited significantly more knee flexion at heel strike and significantly less knee flexion and extension range of motion. No age group differences were present in subtalar joint motion. Impact peak force (1.91 vs 1.70 BW) and maximal initial loading rate (107.5 vs 85.5 BW.s-1) were significantly higher in the older runners at the CRS. Maximal peak vertical and anteroposterior forces and impulses were significantly lower in the older runners at the SRS. The biomechanics of running is different between older- and younger-aged runners on several relevant parameters. The larger impact peak force and initial loading rate indicate a loss of shock-absorbing capacity in the older runners. This may increase their susceptibility to lower-extremity overuse injuries. Moreover, it emphasizes the focus on optimizing cushioning properties in the design and prescription of running shoes and suggests that older-aged runners should be cautious with running under conditions of high impact.
Simulation of the Francis-99 Hydro Turbine During Steady and Transient Operation
NASA Astrophysics Data System (ADS)
Dewan, Yuvraj; Custer, Chad; Ivashchenko, Artem
2017-01-01
Numerical simulation of the Francis-99 hydroturbine with correlation to experimental measurements are presented. Steady operation of the hydroturbine is analyzed at three operating conditions: the best efficiency point (BEP), high load (HL), and part load (PL). It is shown that global quantities such as net head, discharge and efficiency are well predicted. Additionally, time-averaged velocity predictions compare well with PIV measurements obtained in the draft tube immediately downstream of the runner. Differences in vortex rope structure between operating points are discussed. Unsteady operation of the hydroturbine from BEP to HL and from BEP to PL are modeled. It is shown that simulation methods used to model the steady operation produce predictions that correlate well with experiment for transient operation. Time-domain unsteady simulation is used for both steady and unsteady operation. The full-fidelity geometry including all components is meshed using an unstructured polyhedral mesh with body-fitted prism layers. Guide vane rotation for transient operation is imposed using fully-conservative, computationally efficient mesh morphing. The commercial solver STAR-CCM+ is used for all portions of the analysis including meshing, solving and post-processing.
Foot strike and injury rates in endurance runners: a retrospective study.
Daoud, Adam I; Geissler, Gary J; Wang, Frank; Saretsky, Jason; Daoud, Yahya A; Lieberman, Daniel E
2012-07-01
This retrospective study tests if runners who habitually forefoot strike have different rates of injury than runners who habitually rearfoot strike. We measured the strike characteristics of middle- and long-distance runners from a collegiate cross-country team and quantified their history of injury, including the incidence and rate of specific injuries, the severity of each injury, and the rate of mild, moderate, and severe injuries per mile run. Of the 52 runners studied, 36 (69%) primarily used a rearfoot strike and 16 (31%) primarily used a forefoot strike. Approximately 74% of runners experienced a moderate or severe injury each year, but those who habitually rearfoot strike had approximately twice the rate of repetitive stress injuries than individuals who habitually forefoot strike. Traumatic injury rates were not significantly different between the two groups. A generalized linear model showed that strike type, sex, race distance, and average miles per week each correlate significantly (P < 0.01) with repetitive injury rates. Competitive cross-country runners on a college team incur high injury rates, but runners who habitually rearfoot strike have significantly higher rates of repetitive stress injury than those who mostly forefoot strike. This study does not test the causal bases for this general difference. One hypothesis, which requires further research, is that the absence of a marked impact peak in the ground reaction force during a forefoot strike compared with a rearfoot strike may contribute to lower rates of injuries in habitual forefoot strikers.
Validity of the Wingate anaerobic test for the evaluation of elite runners.
Legaz-Arrese, Alejandro; Munguía-Izquierdo, Diego; Carranza-García, Luis E; Torres-Dávila, Celeste G
2011-03-01
This study aimed to determine performance differences, based on the Wingate anaerobic test (WAnT), between homogeneous groups of elite male and female runners competing at distances ranging from 100 m to the marathon. We also attempted to establish a link between running ability and performance as measured by the WAnT. In total, 116 world-class runners (86 men and 30 woman) volunteered to participate in our study. Subjects were tested for peak power (PP, 5-second output) and mean power (MP, 30-second output) using WAnT procedures. Runners were classified into groups according to their best performances times. For male runners, PP and MP outputs decreased with increasing distance (p < 0.001). This trend was also true for female runners (p < 0.005). However, for both sexes, there were no significant differences in the PP values among 100-, 400-, and 800-m runners, and there were also no differences in the MP values for subjects that ran distances of 100 m compared with the values for subjects that ran distances of 400 and 800 m. In addition, no significant differences were observed in the PP and MP values between subjects that ran distances of 800, 1,500, and 3,000 m. Performance in the WAnT was not significantly associated with running performance in any distance event. The results of this study indicate that the WAnT is not a useful tool for the evaluation of elite runners.
Body Composition and Aerobic Requirements of Male and Female Marathon Runners.
ERIC Educational Resources Information Center
Wells, Christine L.; And Others
This study investigates the physical characteristics, body composition, cardiovascular and pulmonary functions, and aerobic capabilities of male and female long distance runners. Eleven runners volunteered to take tests to determine background information, body fat, oxygen uptake, and running time and pace. Conclusions made from this study…
1978 All Indian Long Distance Runner's Training Camp. General Assessment.
ERIC Educational Resources Information Center
Churchill, Ward
The All-Indian Long Distance Runner's Training Camp, predicated upon the fact that the Native American community has produced an inordinate number of long distance runners due to historical/environmental/sociological factors, has as its operational philosophy that academic achievement is stressed as a correlate to athletic success; that…
Increased vertebral bone mineral in response to reduced exercise in amenorrheic runners.
Lindberg, J S; Powell, M R; Hunt, M M; Ducey, D E; Wade, C E
1987-01-01
Seven female runners found to have exercise-induced amenorrhea and decreased bone mineral were reevaluated after 15 months. During the 15-month period, four runners took supplemental calcium and reduced their weekly running distance by 43%, resulting in an average 5% increase in body weight, increased estradiol levels and eumenorrhea. Bone mineral content increased from 1.003+/-0.097 to 1.070+/-0.089 grams per cm.(2) Three runners continued to have amenorrhea, with no change in running distance or body weight. Estradiol levels remained abnormally low and there was no significant change in the bone mineral content, although all three took supplemental calcium. We found that early osteopenia associated with exercise-induced menstrual dysfunction improved when runners reduced their running distance, gained weight and became eumenorrheic.
Remotely replaceable tokamak plasma limiter tiles
Tsuo, Simon , Langford, Alison A.
1989-01-01
U-shaped limiter tiles placed end-to-end over a pair of parallel runners secured to a wall have two rods which engage L-shaped slots in the runners. The short receiving legs of the L-shaped slots are perpendicular to the wall and open away from the wall, while long retaining legs are parallel to and adjacent the wall. A sliding bar between the runners has grooves with clips to retain the rods pressed into receiving legs of the L-shaped slots in the runners. Sliding the bar in the direction of retaining legs of the L-shaped slots latches the tiles in place over the runners. Resilient contact strips between the parallel arms of the U-shaped tiles and the wall assure thermal and electrical contact with the wall.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Siegel, A.J.; Silverman, L.M.; Holman, B.L.
1985-10-01
Elevated cardiac enzyme values in asymptomatic marathon runners after competition can arise from skeletal muscle through exertional rhabdomyolysis, silent injury to the myocardium, or a combined tissue source. Peak post-race levels of the MB isoenzyme of creatine kinase are similar to values in patients with acute myocardial infarction. Previously reported normal results of infarct-avid myocardial scintigraphy with technetium 99m pyrophosphate in runners after competition suggest a non-cardiac source but cannot exclude silent injury to the myocardium. Therefore, thallium 201 myocardial perfusion imaging was performed in runners immediately after competition together with determination of sequential cardiac enzyme levels. Among 15 runnersmore » tested, the average peak in serum MB creatine kinase 24 hours after the race was 128 IU/liter with a cumulative MB creatine kinase release of 117 IU/liter; these values are comparable to those in patients with acute transmural myocardial infarction. Thallium 201 myocardial scintigraphic results were normal in five runners randomly selected from those who volunteered for determination of sequential blood levels. It is concluded that elevations of serum MB creatine kinase in marathon runners arise from a skeletal muscle source and that thallium 201 myocardial scintigraphy is useful to assess runners for myocardial injury when clinical questions arise.« less
Performance analysis of vortex based mixers for confined flows
NASA Astrophysics Data System (ADS)
Buschhagen, Timo
The hybrid rocket is still sparsely employed within major space or defense projects due to their relatively poor combustion efficiency and low fuel grain regression rate. Although hybrid rockets can claim advantages in safety, environmental and performance aspects against established solid and liquid propellant systems, the boundary layer combustion process and the diffusion based mixing within a hybrid rocket grain port leaves the core flow unmixed and limits the system performance. One principle used to enhance the mixing of gaseous flows is to induce streamwise vorticity. The counter-rotating vortex pair (CVP) mixer utilizes this principle and introduces two vortices into a confined flow, generating a stirring motion in order to transport near wall media towards the core and vice versa. Recent studies investigated the velocity field introduced by this type of swirler. The current work is evaluating the mixing performance of the CVP concept, by using an experimental setup to simulate an axial primary pipe flow with a radially entering secondary flow. Hereby the primary flow is altered by the CVP swirler unit. The resulting setup therefore emulates a hybrid rocket motor with a cylindrical single port grain. In order to evaluate the mixing performance the secondary flow concentration at the pipe assembly exit is measured, utilizing a pressure-sensitive paint based procedure.
Propulsion of the Water Flea, Daphnia magna: Experiments, Scaling, and Modelling
NASA Astrophysics Data System (ADS)
Skipper, A. N.; Murphy, D.; Webster, D. R.; Yen, J.
2016-02-01
The freshwater crustacean Daphnia magna is a widely studied zooplankton in relation to food webs, predator-prey interactions, and other biological/ecological considerations; however, their locomotion is poorly quantified and understood. These water fleas utilize a hop-and-sink mechanism that consists of making quick, impulsive jumps by beating their antennae to propel themselves forward ( 1 body length). The animals then sink for a period, during which they stretch out their antennae to increase drag and thereby reduce their sinking velocity. Time-resolved three-dimensional flow fields surrounding the animals were quantified with a unique infrared tomographic particle image velocity (tomo-PIV) system. Three-dimensional kinematics data were also extracted from the image sequences. In the current work, we compared body kinematics and flow disturbance among organisms of size in the range of 1.3 to 2.8 mm. The stroke cycle averaged 150 ms in duration, ranging from 100 to 180 ms; this period is generally evenly split between the power and recovery strokes. The range of peak hop velocity was 27.2 to 32.5 mm/s, and peak acceleration was in the range of 0.68 to 1.8 m/s2. The results showed a distinct relationship between peak hop speed (Vmax 14 BL/s) and body size; these data collapsed onto a single time-record curve during the power stroke when properly non-dimensionalized. The fluid flow induced by each antennae consisted of a viscous vortex ring that demonstrated a slow decay in the wake. The strength, size, and decay of the induced viscous vortex rings were compared as a function of organism size. Finally, the viscous vortex rings were analyzed in the context of a double Stokeslet model that consisted of two impulsively applied point forces separated by the animal width.
Exaggerated gonadotropin response to luteinizing hormone-releasing hormone in amenorrheic runners.
Yahiro, J; Glass, A R; Fears, W B; Ferguson, E W; Vigersky, R A
1987-03-01
Most studies of exercise-induced amenorrhea have compared amenorrheic athletes (usually runners) with sedentary control subjects. Such comparisons will identify hormonal changes that develop as a result of exercise training but cannot determine which of these changes play a role in causing amenorrhea. To obviate this problem, we assessed reproductive hormone status in a group of five amenorrheic runners and compared them to a group of six eumenorrheic runners matched for body fatness, training intensity, and exercise performance. Compared to the eumenorrheic runners, the amenorrheic runners had lower serum estradiol concentrations, similar basal serum luteinizing hormone and follicle-stimulating hormone concentrations, and exaggerated responses of serum gonadotropins after administration of luteinizing hormone-releasing hormone (100 micrograms intravenous bolus). Serum prolactin levels, both basally and after thyrotropin-releasing hormone administration (500 micrograms intravenous bolus) or treadmill exercise, was similar in the two groups, as were serum thyroid function tests (including thyrotropin response to thyrotropin-releasing hormone). Changes in serum cortisol levels after short-term treadmill exercise were similar in both groups, and serum testosterone levels increased after exercise only in the eumenorrheic group. In neither group did such exercise change serum luteinizing hormone, follicle-stimulating hormone, or thyrotropin levels. We concluded that exercise-induced amenorrhea is not solely related to the development of increased prolactin output after exercise training. The exaggerated gonadotropin response to luteinizing hormone-releasing hormone seen in amenorrheic runners in comparison with matched eumenorrheic runners is consistent with a hypothalamic etiology for the menstrual dysfunction, analogous to that previously described in "stress-induced" or "psychogenic" amenorrhea.
Tapering strategies in elite British endurance runners.
Spilsbury, Kate L; Fudge, Barry W; Ingham, Stephen A; Faulkner, Steve H; Nimmo, Myra A
2015-01-01
The aim of the study was to explore pre-competition training practices of elite endurance runners. Training details from elite British middle distance (MD; 800 m and 1500 m), long distance (LD; 3000 m steeplechase to 10,000 m) and marathon (MAR) runners were collected by survey for 7 days in a regular training (RT) phase and throughout a pre-competition taper. Taper duration was [median (interquartile range)] 6 (3) days in MD, 6 (1) days in LD and 14 (8) days in MAR runners. Continuous running volume was reduced to 70 (16)%, 71 (24)% and 53 (12)% of regular levels in MD, LD and MAR runners, respectively (P < 0.05). Interval running volume was reduced compared to regular training (MD; 53 (45)%, LD; 67 (23)%, MAR; 64 (34)%, P < 0.05). During tapering, the peak interval training intensity was above race speed in LD and MAR runners (112 (27)% and 114 (3)%, respectively, P < 0.05), but not different in MD (100 (2)%). Higher weekly continuous running volume and frequency in RT were associated with greater corresponding reductions during the taper (R = -0.70 and R = -0.63, respectively, both P < 0.05). Running intensity during RT was positively associated with taper running intensity (continuous intensity; R = 0.97 and interval intensity; R = 0.81, both P < 0.05). Algorithms were generated to predict and potentially prescribe taper content based on the RT of elite runners. In conclusion, training undertaken prior to the taper in elite endurance runners is predictive of the tapering strategy implemented before competition.
Associations between iliotibial band injury status and running biomechanics in women.
Foch, Eric; Reinbolt, Jeffrey A; Zhang, Songning; Fitzhugh, Eugene C; Milner, Clare E
2015-02-01
Iliotibial band syndrome (ITBS) is a common overuse knee injury that is twice as likely to afflict women compared to men. Lower extremity and trunk biomechanics during running, as well as hip abductor strength and iliotibial band flexibility, are factors believed to be associated with ITBS. The purpose of this cross-sectional study was to determine if differences in lower extremity and trunk biomechanics during running exist among runners with current ITBS, previous ITBS, and controls. Additionally, we sought to determine if isometric hip abductor strength and iliotibial band flexibility were different among groups. Twenty-seven female runners participated in the study. Participants were divided into three equal groups: current ITBS, previous ITBS, and controls. Overground running trials, isometric hip abductor strength, and iliotibial band flexibility were recorded for all participants. Discrete joint and segment biomechanics, as well as hip strength and flexibility measures were analyzed using a one-way analysis of variance. Runners with current ITBS exhibited 1.8 (1.5)° greater trunk ipsilateral flexion and 7 (6)° less iliotibial band flexibility compared to runners with previous ITBS and controls. Runners with previous ITBS exhibited 2.2 (2.9) ° less hip adduction compared to runners with current ITBS and controls. Hip abductor strength 3.3 (2.6) %BM×h was less in runners with previous ITBS but not current ITBS compared to controls. Runners with current ITBS may lean their trunk more towards the stance limb which may be associated with decreased iliotibial band flexibility. Copyright © 2015 Elsevier B.V. All rights reserved.
Energy expenditure and influence of physiologic factors during marathon running.
Loftin, Mark; Sothern, Melinda; Koss, Cathie; Tuuri, Georgianna; Vanvrancken, Connie; Kontos, Anthony; Bonis, Marc
2007-11-01
This study examined energy expenditure and physiologic determinants for marathon performance in recreational runners. Twenty recreational marathon runners participated (10 males aged 41 +/- 11.3 years, 10 females aged 42.7 +/- 11.7 years). Each subject completed a V(.-)O2max and a 1-hour treadmill run at recent marathon pace, and body composition was indirectly determined via dual energy X-ray absorptiometry. The male runners exhibited higher V(.-)O2max (ml x kg(-1) x min(-1)) values (52.6 +/- 5.5) than their female counterparts (41.9 +/- 6.6), although ventilatory threshold (T-vent) values were similar between groups (males: 76.2 +/- 6.1 % of V(.-)O2max, females: 75.1 +/- 5.1%). The male runners expended more energy (2,792 +/- 235 kcal) for their most recent marathon as calculated from the 1-hour treadmill run at marathon pace than the female runners (2,436 +/- 297 kcal). Body composition parameters correlated moderately to highly (r ranging from 0.50 to 0.87) with marathon run time. Also, V(.-)O2max (r = -0.73) and ventilatory threshold (r = -0.73) moderately correlated with marathon run time. As a group, the participants ran near their ventilatory threshold for their most recent marathon (r = 0.74). These results indicate the influence of body size on marathon run performance. In general, the larger male and female runners ran slower and expended more kilocalories than smaller runners. Regardless of marathon finishing time, the runners maintained a pace near their T-vent, and as T-vent or V(.-)O2max increased, marathon performance time decreased.
Is There an Optimal Speed for Economical Running?
Black, Matthew I; Handsaker, Joseph C; Allen, Sam J; Forrester, Stephanie E; Folland, Jonathan P
2018-01-01
The influence of running speed and sex on running economy is unclear and may have been confounded by measurements of oxygen cost that do not account for known differences in substrate metabolism, across a limited range of speeds, and differences in performance standard. Therefore, this study assessed the energy cost of running over a wide range of speeds in high-level and recreational runners to investigate the effect of speed (in absolute and relative terms) and sex (men vs women of equivalent performance standard) on running economy. To determine the energy cost (kcal · kg -1 · km -1 ) of submaximal running, speed at lactate turn point (sLTP), and maximal rate of oxygen uptake, 92 healthy runners (high-level men, n = 14; high-level women, n = 10; recreational men, n = 35; recreational women, n = 33) completed a discontinuous incremental treadmill test. There were no sex-specific differences in the energy cost of running for the recreational or high-level runners when compared at absolute or relative running speeds (P > .05). The absolute and relative speed-energy cost relationships for the high-level runners demonstrated a curvilinear U shape with a nadir reflecting the most economical speed at 13 km/h or 70% sLTP. The high-level runners were more economical than the recreational runners at all absolute and relative running speeds (P < .05). These findings demonstrate that there is an optimal speed for economical running, there is no sex-specific difference, and high-level endurance runners exhibit better running economy than recreational endurance runners.
The Runners and Injury Longitudinal Study: Injury Recovery Supplement (TRAILS_IR)
2013-08-01
2) develop statistical models that integrate biomechanical, behavioral, and psychological risk factors for injury, (3) determine the length of...Running Mechanics and Flexibility Between Runners in Minimalist and Traditional Footwear ”......14...annual meeting entitled “Differences in Running Mechanics and Flexibility between Runners in Minimalist and Traditional Footwear ”. The following
Training Habits and Injury Experience in Distance Runners: Age- and Sex-Related Factors.
ERIC Educational Resources Information Center
Walter, Stephen D.
1988-01-01
An 80-item questionnaire was used to study variations by age and sex in the training habits and injury experience of 688 adult distance runners. The results are analyzed according to these variables. Methodology is discussed. This is part of a longitudinal study of 1,700 runners. (Author/JL)
de Almeida, Matheus Oliveira; Saragiotto, Bruno Tirotti; Yamato, Tiê Parma; Lopes, Alexandre Dias
2015-02-01
To determine the distribution of the foot strike patterns among recreational shod runners and to compare the personal and training characteristics between runners with different foot strike patterns. Cross-sectional study. Areas of running practice in São Paulo, Brazil. 514 recreational shod runners older than 18 years and free of injury. Foot strike patterns were evaluated with a high-speed camera (250 Hz) and photocells to assess the running speed of participants. Personal and training characteristics were collected through a questionnaire. The inter-rater reliability of the visual foot strike pattern classification method was 96.7% and intra-rater reliability was 98.9%. 95.1% (n = 489) of the participants were rearfoot strikers, 4.1% (n = 21) were midfoot strikers, and four runners (0.8%) were forefoot strikers. There were no significant differences between strike patterns for personal and training characteristics. This is the first study to demonstrate that almost all recreational shod runners were rearfoot strikers. The visual method of evaluation seems to be a reliable and feasible option to classify foot strike pattern. Copyright © 2014 Elsevier Ltd. All rights reserved.
Repair of the DSS-14 Pedestal Concrete
NASA Technical Reports Server (NTRS)
Mcclure, D.
1985-01-01
About three years after the Goldstone Deep Space Station antenna was dedicated, grout under the hydrostatic bearing runner was found to be interacting with the runner, causing rust to form between the runner and the sole plates upon which it rests. The rust formed unevenly and the runner could not be kept flat so in 1969 the grout was removed and replaced with a Portland cement and sand dry pack grout that was less likely to produce rust. In the years that followed, oil leaking from the runner assembly caused progressive deterioration of the drypack grout. In 1982 over one thousand hours of spacecraft tracking time were lost due to this deterioration. A plan was developed to rehabilitate the bearing. The plan called for raising the rotating structure free from the concrete pedestal and placing it on three pairs of external support columns. With the weight of the structure transferred to the columns, the pads and runner could be removed and the repair started. The very successful repair included the replacement of a significant portion of the antenna pedestal.
The role of non-steroidal anti-inflammatory drugs in sports injuries.
D'Ambrosia, R
1987-01-01
The running population in the United States is estimated to be more than 60 million, and two out of every three of these runners will seek medical attention because of injuries. The cause of lower extremity injuries is the impulsive impact that occurs on foot strike. At 800 foot strikes per mile, a 150-pound runner will be subjected to forces of 120 tons per foot per mile. The use of the non-steroidal anti-inflammatory drugs (NSAIDs) in runners has become widespread. This is especially true in the case of marathon runners who use NSAIDs like piroxicam to relieve their overuse pains so they can continue to run with injuries, although this use is not advocated. NSAIDs do, however, play a role in treating many running injuries and can help the runner return to his chosen sport.
Increased Vertebral Bone Mineral in Response to Reduced Exercise in Amenorrheic Runners
Lindberg, Jill S.; Hunt, Marjorie M.; Wade, Charles E.; Powell, Malcolm R.; Ducey, Diane E.
1987-01-01
Seven female runners found to have exercise-induced amenorrhea and decreased bone mineral were reevaluated after 15 months. During the 15-month period, four runners took supplemental calcium and reduced their weekly running distance by 43%, resulting in an average 5% increase in body weight, increased estradiol levels and eumenorrhea. Bone mineral content increased from 1.003±0.097 to 1.070±0.089 grams per cm.2 Three runners continued to have amenorrhea, with no change in running distance or body weight. Estradiol levels remained abnormally low and there was no significant change in the bone mineral content, although all three took supplemental calcium. We found that early osteopenia associated with exercise-induced menstrual dysfunction improved when runners reduced their running distance, gained weight and became eumenorrheic. ImagesFigure 1. PMID:3825107
Investigation of distributor vane jets to decrease the unsteady load on hydro turbine runner blades
NASA Astrophysics Data System (ADS)
Lewis, B. J.; Cimbala, J. M.; Wouden, A. M.
2012-11-01
As the runner blades of a Francis hydroturbine pass though the wakes created from the wicket gates, they experience a significant change in absolute velocity, flow angle, and pressure. The concept of adding jets to the trailing edge of the wicket gates is proposed as a method for reducing the dynamic load on the hydroturbine runner blades. Computational experiments show a decrease in velocity variation experienced by the runner blade with the addition of the jets. The decrease in velocity variation resulted in a 43% decrease in global torque variation at the runner passing frequency. However, an increased variation was observed at the wicket gate passing frequency. Also, a 5.7% increase in average global torque was observed with the addition of blowing from the trailing-edge of the wicket gates.
Study on the effect of the runner design parameters on 50 MW Francis hydro turbine model performance
NASA Astrophysics Data System (ADS)
Shrestha, Ujjwal; Chen, Zhenmu; Choi, Young-Do
2018-06-01
Francis hydro turbine is the dominant turbine in the hydropower generation. Francis turbine has been installed at most 60% of the hydropower in the world at present. Although the basic design for the Francis turbine has various method regarding the specific speed. The runner meridional shape varies with different specific speed. Despite having, the basic design but there is still some room for the optimization. In this study 50 MW, Francis hydro turbine with specific speed 323 m-kW was designed and considered for the optimization. The various parameter as runner meridional shape (curve profile of hub, shroud, leading edge and trailing edge), blade angle and its distribution, blade thickness, runner inlet width that has been considered for the optimization of the runner for enhancement of the performance.
2013-01-01
Background The growing interest in marathon runners and marathons in Nigeria has not been reflected in reports of injuries and other health problems associated with these events. This study therefore outlines the incidence of injuries, marathon-related health problems and delivery of physiotherapy at the maiden and second editions of the Splash 105.5 FM/ICPC Integrity Marathon in Ibadan city, south-west Nigeria in 2009 and 2010. Methods Using a data entry sheet, demographics and information on running experience, past and present injuries and other health problems reported en route and at the finish line by the runners were documented. The prevalence of injuries and other health problems reported by previous and first-time runners were compared. Results In both events, 16.3% and 17.2% of the runners respectively reported injuries with significant occurrence in first-time runners (p = 0.003 for 2009; p = 0.002 for 2010) mostly at the finish line. The reported injury type and site were muscle cramps and the thigh (39.7% and 76.4% respectively). Heat exhaustion was reported by 42.8% of runners in 2009 and 56.3% in 2010. Cryotherapy was mostly used in combination with other physiotherapy modalities in both years. Conclusion Most of the injuries and other health problems were reported by first-time marathon runners mainly at the finish line. The most reported site of injury was the thigh while muscle cramps and heat exhaustions were the most reported types of injuries and health problems. First-time marathon runners should be adequately informed of the predisposition to injury during marathons and adequate body conditioning should be emphasized. Ample preparation and effective involvement of the physiotherapy team is essential for management of injured runners en route and at the finish line in a marathon. PMID:24499546
Foot Kinematics Differ Between Runners With and Without a History of Navicular Stress Fractures
Becker, James; James, Stanley; Osternig, Louis; Chou, Li-Shan
2018-01-01
Background: A navicular stress fracture (NSF) is a common and high-risk injury in distance runners. It is not clear whether there are differences in foot structure and function between runners who have and those who have not sustained an NSF. Purpose/Hypothesis: This study compared foot structure, range of motion, and biomechanics between runners with a history of unilateral NSFs and runners who had never sustained this injury. The hypothesis was that runners with a history of NSFs will have less dorsiflexion and subtalar range of motion in a clinical examination and greater rearfoot eversion and higher eversion velocity while running than either the noninvolved feet or healthy controls. Study Design: Cross-sectional study; Level of evidence, 3. Methods: Seven runners who sustained an NSF were matched with 7 controls without this injury history. Participants underwent a clinical orthopaedic examination, followed by a 3-dimensional running gait analysis. Clinical examination variables, foot kinematics, and ground-reaction forces were compared between injured and noninjured feet within the NSF group and between the NSF group and control group. Results: The NSF group demonstrated less plantar flexion on the clinical examination than the control group (P = .034, effect size [ES] = 0.69). The involved feet of the NSF group demonstrated greater rearfoot eversion excursion, greater eversion velocity, and reduced forefoot abduction excursion than either the noninvolved feet of the NSF group (P = .015, ES = 1.73; P = .015, ES = 1.86; and P = .015, ES = 0.96, respectively) or the control group (P = .012, ES = 1.40; P = .016, ES = 0.49; and P = .005, ES = 1.60, respectively). Conclusion: There are differences in foot kinematics but not ground-reaction forces, foot structure, or passive range of motion between runners who have and those who have not sustained an NSF. Runners who demonstrate increased rearfoot eversion and reduced forefoot abduction during stance may be more at risk for developing NSFs. PMID:29780837
Foot strike patterns of runners at the 15-km point during an elite-level half marathon.
Hasegawa, Hiroshi; Yamauchi, Takeshi; Kraemer, William J
2007-08-01
There are various recommendations by many coaches regarding foot landing techniques in distance running that are meant to improve running performance and prevent injuries. Several studies have investigated the kinematic and kinetic differences between rearfoot strike (RFS), midfoot strike (MFS), and forefoot strike (FFS) patterns at foot landing and their effects on running efficiency on a treadmill and over ground conditions. However, little is known about the actual condition of the foot strike pattern during an actual road race at the elite level of competition. The purpose of the present study was to document actual foot strike patterns during a half marathon in which elite international level runners, including Olympians, compete. Four hundred fifteen runners were filmed by 2 120-Hz video cameras in the height of 0.15 m placed at the 15.0-km point and obtained sagittal foot landing and taking off images for 283 runners. Rearfoot strike was observed in 74.9% of all analyzed runners, MFS in 23.7%, and FFS in 1.4%. The percentage of MFS was higher in the faster runners group, when all runners were ranked and divided into 50 runner groups at the 15.0-km point of the competition. In the top 50, which included up to the 69th place runner in actual order who passed the 15-km point at 45 minutes, 53 second (this speed represents 5.45 m x s(-1), or 15 minutes, 17 seconds per 5 km), RFS, MFS, and FFS were 62.0, 36.0, and 2.0%, respectively. Contact time (CT) clearly increased for the slower runners, or the placement order increased (r = 0.71, p < or = 0.05). The CT for RFS + FFS for every 50 runners group significantly increased with increase of the placement order. The CT for RFS was significantly longer than MFS + FFS (200.0 +/- 21.3 vs. 183.0 +/- 16 millisecond). Apparent inversion (INV) of the foot at the foot strike was observed in 42% of all runners. The percentage of INV for MFS was higher than for RFS and FFS (62.5, 32.0, and 50%, respectively). The CT with INV for MFS + FFS was significantly shorter than the CT with and without INV for RFS. Furthermore, the CT with INV was significantly shorter than push-off time without INV for RFS. The findings of this study indicate that foot strike patterns are related to running speed. The percentage of RFS increases with the decreasing of the running speed; conversely, the percentage of MFS increases as the running speed increases. A shorter contact time and a higher frequency of inversion at the foot contact might contribute to higher running economy.
Melanoma markers in marathon runners: increase with sun exposure and physical strain.
Richtig, Erika; Ambros-Rudolph, Christina M; Trapp, Michael; Lackner, Helmut K; Hofmann-Wellenhof, Rainer; Kerl, Helmut; Schwaberger, Guenther
2008-01-01
Marathon runners seem to have an increased melanoma risk. To identify potential melanoma markers. 150 marathon runners volunteered to take part in the skin cancer screening campaign. After the runners completed a questionnaire about melanoma risk factors, types of sportswear and training programs, they received a total skin examination. The number of lentigines and nevi on the left shoulder and the left buttock were counted in each participant using templates in standardized positions. The potential association of training sportswear and training parameters with the number of lentigines and nevi on the left shoulder was evaluated. The mean number of lentigines on the left shoulder was 19.6 +/- 18.2 (SD), whereas no lentigines were found on the left buttock (p = 0.000). The number of nevi also differed significantly between the 2 localizations with higher numbers on the left shoulder (p = 0.000). While lifetime sunburn history and type of sportswear correlated with the number of lentigines, training parameters had an impact on the number of nevi. Independent of their mean weekly running time, runners with higher heart rates while training, higher training velocities and higher physical strain indexes showed more nevi on the shoulder than the other runners (p = 0.029, 0.046, 0.038, respectively). Sun exposure and high physical strain lead to an increase in melanoma markers such as lentigines and nevi in marathon runners. Copyright 2008 S. Karger AG, Basel.
Chen, T L; An, W W; Chan, Z Y S; Au, I P H; Zhang, Z H; Cheung, R T H
2016-03-01
Tibial stress fracture is a common injury in runners. This condition has been associated with increased impact loading. Since vertical loading rates are related to the landing pattern, many heelstrike runners attempt to modify their footfalls for a lower risk of tibial stress fracture. Such effect of modified landing pattern remains unknown. This study examined the immediate effects of landing pattern modification on the probability of tibial stress fracture. Fourteen experienced heelstrike runners ran on an instrumented treadmill and they were given augmented feedback for landing pattern switch. We measured their running kinematics and kinetics during different landing patterns. Ankle joint contact force and peak tibial strains were estimated using computational models. We used an established mathematical model to determine the effect of landing pattern on stress fracture probability. Heelstrike runners experienced greater impact loading immediately after landing pattern switch (P<0.004). There was an increase in the longitudinal ankle joint contact force when they landed with forefoot (P=0.003). However, there was no significant difference in both peak tibial strains and the risk of tibial stress fracture in runners with different landing patterns (P>0.986). Immediate transitioning of the landing pattern in heelstrike runners may not offer timely protection against tibial stress fracture, despite a reduction of impact loading. Long-term effects of landing pattern switch remains unknown. Copyright © 2016 Elsevier Ltd. All rights reserved.
Foot strike patterns and collision forces in habitually barefoot versus shod runners.
Lieberman, Daniel E; Venkadesan, Madhusudhan; Werbel, William A; Daoud, Adam I; D'Andrea, Susan; Davis, Irene S; Mang'eni, Robert Ojiambo; Pitsiladis, Yannis
2010-01-28
Humans have engaged in endurance running for millions of years, but the modern running shoe was not invented until the 1970s. For most of human evolutionary history, runners were either barefoot or wore minimal footwear such as sandals or moccasins with smaller heels and little cushioning relative to modern running shoes. We wondered how runners coped with the impact caused by the foot colliding with the ground before the invention of the modern shoe. Here we show that habitually barefoot endurance runners often land on the fore-foot (fore-foot strike) before bringing down the heel, but they sometimes land with a flat foot (mid-foot strike) or, less often, on the heel (rear-foot strike). In contrast, habitually shod runners mostly rear-foot strike, facilitated by the elevated and cushioned heel of the modern running shoe. Kinematic and kinetic analyses show that even on hard surfaces, barefoot runners who fore-foot strike generate smaller collision forces than shod rear-foot strikers. This difference results primarily from a more plantarflexed foot at landing and more ankle compliance during impact, decreasing the effective mass of the body that collides with the ground. Fore-foot- and mid-foot-strike gaits were probably more common when humans ran barefoot or in minimal shoes, and may protect the feet and lower limbs from some of the impact-related injuries now experienced by a high percentage of runners.
Medial tibial stress syndrome in high school cross-country runners: incidence and risk factors.
Plisky, Melody S; Rauh, Mitchell J; Heiderscheit, Bryan; Underwood, Frank B; Tank, Robert T
2007-02-01
Prospective cohort. To determine (1) the cumulative seasonal incidence and overall injury rate of medial tibial stress syndrome (MTSS) and (2) risk factors for MTSS with a primary focus on the relationship between navicular drop values and MTSS in high school cross-country runners. MTSS is a common injury among runners. However, few studies have reported the injury rate and risk factors for MTSS among adolescent runners. Data collected included measurement of bilateral navicular drop and foot length, and a baseline questionnaire regarding the runner's height, body mass, previous running injury, running experience, and orthotic or tape use. Runners were followed during the season to determine athletic exposures (AEs) and occurrence of MTSS. The overall injury rate for MTSS was 2.8/1000 AEs. Although not statistically different, girls had a higher rate (4.3/1000 AEs) than boys (1.7/1000 AEs) (P = .11). Logistic regression modeling indicated that only gender and body mass index (BMI) were significantly associated with the occurrence of MTSS. However, when controlled for orthotic use, only BMI was associated with risk of MTSS. No significant associations were found between MTSS and navicular drop or foot length. Our findings suggest that navicular drop may not be an appropriate measure to identify runners who may develop MTSS during a cross-country season; thus, additional studies are needed to identify appropriate preseason screening tools.
Pamukoff, Derek N; Blackburn, J Troy
2015-02-01
Greater lower extremity joint stiffness may be related to the development of tibial stress fractures in runners. Musculotendinous stiffness is the largest contributor to joint stiffness, but it is unclear what factors contribute to musculotendinous stiffness. The purpose of this study was to compare plantar flexor musculotendinous stiffness, architecture, geometry, and Achilles tendon stiffness between male runners with and without a history of tibial stress fracture. Nineteen healthy runners (age = 21 ± 2.7 years; mass = 68.2 ± 9.3 kg; height = 177.3 ± 6.0 cm) and 19 runners with a history of tibial stress fracture (age = 21 ± 2.9 years; mass = 65.3 ± 6.0 kg; height = 177.2 ± 5.2 cm) were recruited from community running groups and the university's varsity and club cross-country teams. Plantar flexor musculotendinous stiffness was estimated from the damped frequency of oscillatory motion about the ankle follow perturbation. Ultrasound imaging was used to measure architecture and geometry of the medial gastrocnemius. Dependent variables were compared between groups via one-way ANOVAs. Previously injured runners had greater plantar flexor musculotendinous stiffness (P < .001), greater Achilles tendon stiffness (P = .004), and lesser Achilles tendon elongation (P = .003) during maximal isometric contraction compared with healthy runners. No differences were found in muscle thickness, pennation angle, or fascicle length.
The nature and response to therapy of 196 consecutive injuries seen at a runners' clinic.
Pinshaw, R; Atlas, V; Noakes, T D
1984-02-25
We studied a series of 196 running injuries to determine the nature of the common injuries, the type of runners with the different injuries, specific factors causing the most common injuries, and the response of these injuries to correction of the biomechanical abnormalities believed to cause them. The four commonest injuries were 'runner's knee' (peripatellar pain syndrome) (22%), 'shin splints' (posterior tibial stress syndrome) (18%), the iliotibial band friction syndrome (12%), and chronic muscle injuries (11%). Within 8 weeks of following the biomechanically based treatment regimen, between 62% and 77% of the runners with the commonest injuries were completely pain-free and running almost the same training distance as before injury. Only 13% of runners were not helped at all, but most of these had not adhered to the prescribed treatment. The response of the iliotibial band syndrome to treatment was less predictable, however, and some runners who followed the advice faithfully were not helped. These data therefore confirm the importance of biomechanical factors in running injuries and indicate that practitioners involved in the care of injured runners need to know not only how to diagnose the conditions accurately but also which running shoes are appropriate for the different running injuries, how to detect subtle lower limb structural abnormalities, in particular foot abnormalities and leg-length inequalities, and when to prescribe in-shoe orthoses.
Barefoot-simulating footwear associated with metatarsal stress injury in 2 runners.
Giuliani, Jeffrey; Masini, Brendan; Alitz, Curtis; Owens, Brett D
2011-07-07
Stress-related changes and fractures in the foot are frequent in runners. However, the causative factors, including anatomic and kinematic variables, are not well defined. Footwear choice has also been implicated in contributing to injury patterns with changes in force transmission and gait analyses reported in the biomechanical literature. Despite the benefits of footwear, there has been increased interest among the running community in barefoot running with proposed benefits including a decreased rate of injury. We report 2 cases of metatarsal stress fracture in experienced runners whose only regimen change was the adoption of barefoot-simulating footwear. One was a 19-year-old runner who developed a second metatarsal stress reaction along the entire diaphysis. The second case was a 35-year-old ultra-marathon runner who developed a fracture in the second metatarsal diaphysis after 6 weeks of use of the same footwear. While both stress injuries healed without long-term effects, these injuries are alarming in that they occurred in experienced male runners without any other risk factors for stress injury to bone. The suspected cause for stress injury in these 2 patients is the change to barefoot-simulating footwear. Runners using these shoes should be cautioned on the potential need for gait alterations from a heel-strike to a midfoot-striking pattern, as well as cautioned on the symptoms of stress injury. Copyright 2011, SLACK Incorporated.
Injection dynamics of gelled propellants
NASA Astrophysics Data System (ADS)
Yoon, Changjin
Gel propellants have been recognized as attractive candidates for future propulsion systems due to the reduced tendency to spill and the energy advantages over solid propellants. One of strong benefits emphasized in gel propellant applications is a throttling capability, but the accurate flow control is more complicated and difficult than with conventional Newtonian propellants because of the unique rheological behaviors of gels. This study is a computational effort directed to enhance understanding of the injector internal flow characteristics for gel propellants under rocket injection conditions. In simulations, the emphasized rheology is a shear-thinning which represents a viscosity decrease with increasing a shear rate. It is described by a generalized Newtonian fluid constitutive equation and Carreau-Yasuda model. Using this rheological model, two injection schemes are considered in the present study: axially-fed and cross-fed injection for single-element and multi-element impinging injectors, respectively. An axisymmetric model is developed to describe the axially-fed injector flows and fully three-dimensional model is utilized to simulate cross-fed injector flows. Under axially-fed injection conditions investigated, three distinct modes, an unsteady, steady, and hydraulic flip mode, are observed and mapped in terms of Reynolds number and orifice design. In an unsteady mode, quasi-periodic oscillations occur near the inlet lip leading mass pulsations and viscosity fluctuations at the orifice exit. This dynamic behavior is characterized using a time-averaged discharge coefficient, oscillation magnitude and frequency by a parametric study with respect to an orifice design, Reynolds number and rheology. As a result, orifice exit flows for gel propellants appear to be significantly influenced by a viscous damping and flow resistance due to a shear thinning behavior and these are observed in each factors considered. Under conditions driven by a manifold crossflow, unsteady and asymmetric flow structures are revealed as a series of vortices generated from the unstable vena contracta. Here, flows are characterized by an orifice design, manifold/core injection velocity ratio, Reynolds number and rheology. A significant decrease of discharge coefficients is noted with increasing the manifold flow. As the manifold crossflow increases, stronger friction losses are exerted on the leeward, and lead to larger hydraulic losses across the injector. In addition, calculations show that discharge coefficients decrease and the unsteadiness is mitigated as the viscosity increases by fluid rheology variations. A larger and more distinct horseshoe vortex is observed, and pulsation magnitude and viscosity fluctuations are mitigated with increasing viscosity. The oscillation frequency, however, remains unchanged even though the viscosity curves at the high shear rate are modified. All these observations confirm the conclusion that the role of viscous damping and flow resistance is more critical in cross-fed injection conditions than in axially-fed one.
Shin Splints 101: Explaining Shin Splints to Young Runners
ERIC Educational Resources Information Center
Newlin, Dana; Smith, Darla S.
2011-01-01
Shin splints are a common but often confusing injury. Sources disagree on both the cause of the injury and the anatomical source of the pain. Some blame shin splints on foot pronation, footstrike pattern, or arch height. Regardless of what causes the condition, it affects many runners, beginning in some at a young age. Young runners often have…
Body Mass, Training, Menses, and Bone in Adolescent Runners: A 3-y Follow-Up
USDA-ARS?s Scientific Manuscript database
Abstract: Endurance runners with low bone mass during adolescence may be at risk of developing a low peak bone mineral density (BMD) as a young adult. However, it is possible that they mature late and undergo delayed bone mass accumulation. PURPOSE: We evaluated 40 adolescent runners (age 15.9 ± 0....
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-05
... Collection; Importation of French Beans and Runner Beans From Kenya Into the United States AGENCY: Animal and... information collection associated with the regulations for the importation of French beans and runner beans... French beans and runner beans from Kenya, contact Mr. Dennis Martin, Trade Director, PPQ, APHIS, 4700...
Technology for Transient Simulation of Vibration during Combustion Process in Rocket Thruster
NASA Astrophysics Data System (ADS)
Zubanov, V. M.; Stepanov, D. V.; Shabliy, L. S.
2018-01-01
The article describes the technology for simulation of transient combustion processes in the rocket thruster for determination of vibration frequency occurs during combustion. The engine operates on gaseous propellant: oxygen and hydrogen. Combustion simulation was performed using the ANSYS CFX software. Three reaction mechanisms for the stationary mode were considered and described in detail. The way for obtaining quick CFD-results with intermediate combustion components using an EDM model was found. The way to generate the Flamelet library with CFX-RIF was described. A technique for modeling transient combustion processes in the rocket thruster was proposed based on the Flamelet library. A cyclic irregularity of the temperature field like vortex core precession was detected in the chamber. Frequency of flame precession was obtained with the proposed simulation technique.
NASA Technical Reports Server (NTRS)
Kandula, M.; Pearce, D. G.
1991-01-01
A steady incompressible three-dimensional viscous flow analysis has been conducted for the Space Shuttle external tank/orbiter propellant feed line disconnect flapper valves with upstream elbows. The Navier-Stokes code, INS3D, is modified to handle interior obstacles and a simple turbulence model. The flow solver is tested for stability and convergence in the presence of interior flappers. An under-relaxation scheme has been incorporated to improve the solution stability. Important flow characteristics such as secondary flows, recirculation, vortex and wake regions, and separated flows are observed. Computed values for forces, moments, and pressure drop are in satisfactory agreement with water flow test data covering a maximum tube Reynolds number of 3.5 million. The predicted hydrodynamical stability of the flappers correlates well with the measurements.
Van Biesen, Debbie; Hettinga, Florentina J; McCulloch, Katina; Vanlandewijck, Yves
2016-01-01
Pacing has been defined as the goal-directed regulation of exercise intensity over an exercise bout, in which athletes need to decide how and when to invest their energy. The purpose of this study was to explore if the regulation of exercise intensity during competitive track races is different between runners with and without intellectual impairment, which is characterized by significant limitations in intellectual functioning (IQ ≤ 75) and adaptive behavioral deficits, diagnosed before the age of 18. The samples included elite runners with intellectual impairment ( N = 36) and a comparison group of world class runners without impairment ( N = 39), of which 47 were 400 m runners (all male) and 28 were 1500 m-runners (15 male and 13 female). Pacing was analyzed by means of 100 m split times (for 400 m races) and 200 m split times (for 1500 m races). Based on the split times, the average velocity was calculated for four segments of the races. Velocity fluctuations were defined as the differences in velocity between consecutive race segments. A mixed model ANOVA revealed significant differences in pacing profiles between runners with and without intellectual impairment ( p < 0.05). Maximal velocity of elite 400 m runners with intellectual impairment in the first race segment (7.9 ± 0.3 m/s) was well below the top-velocity reached by world level 400 m runners without intellectual impairment (8.9 ± 0.2 m/s), and their overall pace was slower ( F = 120.7, p < 0.05). In addition, both groups followed a different pacing profile and inter-individual differences in pacing profiles were larger, with differences most pronounced for 1500 m races. Whereas, male 1500 m-runners without intellectual impairment reached a high velocity in the first 100 m (7.2 ± 0.1 m/s), slowly decelerated in the second race segment (-0.6 ± 0.1 m/s), and finished with an end sprint (+0.9 ± 0.1 m/s); the 1500 m runners with intellectual impairment started slower (6.1 ± 0.3 m/s), accelerated in the second segment (+0.2 ± 0.7 m/s), and then slowly decreased until the finish ( F = 6.8, p < 0.05). Our findings support the hypothesis that runners with intellectual impairment have difficulties to efficiently self-regulate their exercise intensity. Their limited cognitive resources may constrain the successful integration of appropriate pacing strategies during competitive races.
Alentorn-Geli, Eduard; Samuelsson, Kristian; Musahl, Volker; Green, Cynthia L; Bhandari, Mohit; Karlsson, Jón
2017-06-01
Study Design Systematic review and meta-analysis. Background Running is a healthy and popular activity worldwide, but data regarding its association with osteoarthritis (OA) are conflicting. Objectives To evaluate the association of hip and knee OA with running and to explore the influence of running intensity on this association. Methods PubMed, Embase, and Cochrane Library databases were used to identify studies investigating the occurrence of OA of the hip and/or knee among runners. A meta-analysis of studies comparing this occurrence between runners and controls (sedentary, nonrunning individuals) was conducted. Runners were regarded as "competitive" if they were reported as professional/elite athletes or participated in international competitions. Recreational runners were individuals running in a nonprofessional (amateur) context. The prevalence rate and odds ratio (with 95% confidence interval [CI]) for OA between runners (at competitive and recreational levels) and controls were calculated. Subgroup analyses were conducted for OA location (hip or knee), sex, and years of exposure to running (less or more than 15 years). Results Twenty-five studies (n = 125810 individuals) were included and 17 (n = 114829 individuals) were meta-analyzed. The overall prevalence of hip and knee OA was 13.3% (95% CI: 11.6%, 15.2%) in competitive runners, 3.5% (95% CI: 3.4%, 3.6%) in recreational runners, and 10.2% (95% CI: 9.9%, 10.6%) in controls. The odds ratio for hip and/or knee OA in competitive runners was higher than that in recreational runners (1.34; 95% CI: 0.97, 1.86 and 0.86; 95% CI: 0.69, 1.07, respectively; controls as reference group; for difference, P<.001). Exposure to running of less than 15 years was associated with a lower association with hip and/or knee OA compared with controls (OR = 0.6; 95% CI: 0.49, 0.73). Conclusion Recreational runners had a lower occurrence of OA compared with competitive runners and controls. These results indicated that a more sedentary lifestyle or long exposure to high-volume and/or high-intensity running are both associated with hip and/or knee OA. However, it was not possible to determine whether these associations were causative or confounded by other risk factors, such as previous injury. Level of Evidence Etiology/harm, level 2a. J Orthop Sports Phys Ther 2017;47(6):373-390. doi:10.2519/jospt.2017.7137.
Smits, Dirk-Wouter; Huisstede, Bionka; Verhagen, Evert; van der Worp, Henk; Kluitenberg, Bas; van Middelkoop, Marienke; Hartgens, Fred; Backx, Frank
2016-11-01
To describe absenteeism and health care utilization (HCU) within 6 weeks after occurrence of running-related injuries (RRIs) among novice runners and to explore differences relating to injury and personal characteristics. Prospective cohort study. Primary care. One thousand six hundred ninety-six novice runners (18-65 years) participating in a 6-week running program ("Start-to-Run"). Injury characteristics were assessed by weekly training logs and personal characteristics by a baseline questionnaire. Data on absenteeism and HCU were collected using questionnaires at 2 and 6 weeks after the RRI occurred. A total of 185 novice runners (11%) reported an RRI during the 6-week program. Of these injured novice runners, 78% reported absence from sports, whereas only 4% reported absence from work. Fifty-one percent of the injured novice runners visited a health care professional, mostly physical therapists (PTs) rather than physicians. Absenteeism was more common among women than men and was also more common with acute RRIs than gradual-onset RRIs. As regards HCU, both the variety of professionals visited and the number of PT visits were higher among runners with muscle-tendon injuries in the ankle/foot region than among those with other RRIs. Among novice runners sustaining an RRI during a 6-week running program, over three quarters reported short-term absence from sports, whereas absence from work was very limited, and over half used professional health care. Both absence and HCU are associated with injury characteristics. In future running promotion programs (eg in Start-to-Run programs), specific attention should be paid to acute injuries and to muscle-tendon injuries in the ankle/foot region.
Svedenhag, J; Sjödin, B
1984-10-01
Physiological characteristics of elite runners from different racing events were studied. Twenty-seven middle- and long-distance runners and two 400-m runners belonging to the Swedish national team in track and field were divided, according to their distance preferences, into six groups from 400 m up to the marathon. The maximal oxygen uptake (VO2 max, ml X kg-1 X min-1) on the treadmill was higher the longer the main distance except for the marathon runners (e.g., 800-1500-m group, 72.1; 5000-10,000-m group, 78.7 ml X kg-1 X min-1). Running economy evaluated from oxygen uptake measurements at 15 km/h (VO2 15) and 20 km/h (VO2 20) did not differ significantly between the groups even though VO2 15 tended to be lower in the long-distance runners. The running velocity corresponding to a blood lactate concentration of 4 mmol/l (vHla 4.0) differed markedly between the groups with the highest value (5.61 m/s) in the 5000-10,000-m group. The oxygen uptake (VO2) at vHla 4.0 in percentage of VO2 max did not differ significantly between the groups. The blood lactate concentration after exhaustion (VO2 max test) was lower in the long-distance runners. In summary, the present study demonstrates differences in physiological characteristics of elite runners specializing in different racing events. The two single (but certainly inter-related) variables in which this was most clearly seen were the maximal oxygen uptake (ml X kg-1 X min-1) and the running velocity corresponding to a blood lactate concentration of 4 mmol/l.
Health Culture and Running: Non-Elite Runners’ Understandings of Doping and Supplementation
Henning, April D.
2016-01-01
Participants at the non-elite level of road running often take up the sport for purposes of health, as a way of taking responsibility for their own well-being. Often, these runners use dietary supplements as a way to improve health and to potentially enhance running performance. Supplements are distinct from banned performance enhancing drugs (PEDs), as they are legal and widely available, though very loosely regulated. Research demonstrates that the line between supplements and banned PEDs is increasingly blurry as cases of cross-contaminated and mislabeled supplements continue to be found. Such products may pose health risks to unsuspecting consumers. Despite anti-doping agencies’ warnings to elite runners about these risks, non-elite runners are rarely told by any sport or anti-doping body to be wary of supplements. They are, however, inundated with media coverage of doping scandals usually involving only a few of the substances banned in sport. In short, these runners are often left to navigate supplement use on their own and many conflate supplement availability with safety. This article explores these routine dietary supplement practices among non-elite runners. Drawing from interviews with 28 non-elite runners in New York City, I discuss the perceptions and understandings of doping and dietary supplement use within the context of health culture. Interview data reveal that the social acceptance of dietary supplements and their widespread use among the broader public reinforce the notion among non-elite runners that such products are objectively safe and healthy. I argue that based on their assumptions of supplement safety, non-elite runners view dietary supplements as distinctly different from PEDs and that this difference encourages their use as health and performance aids. PMID:28782003
Bennett, Jason E; Reinking, Mark F; Rauh, Mitchell J
2012-06-01
The purpose of this study was to examine the relationships between isotonic ankle plantar flexor endurance (PFE), foot pronation as measured by navicular drop, and exercise-related leg pain (ERLP). Exercise-related leg pain is a common occurrence in competitive and recreational runners. The identification of factors contributing to the development of ERLP may help guide methods for the prevention and management of overuse injuries. Seventy-seven (44 males, 33 females) competitive runners from five collegiate cross-country (XC) teams consented to participate in the study. Isotonic ankle PFE and foot pronation were measured using the standing heel-rise and navicular drop (ND) tests, respectively. Demographic information, anthropometric measurements, and ERLP history were also recorded. Subjects were then prospectively tracked for occurrence of ERLP during the 2009 intercollegiate cross-country season. Multivariate logistic regression analysis was used to examine the relationships between isotonic ankle joint PFE and ND and the occurrence of ERLP. While no significant differences were identified for isotonic ankle PFE between groups of collegiate XC runners with and without ERLP, runners with a ND >10 mm were almost 7 times (OR=6.6, 95% CI=1.2-38.0) more likely to incur medial ERLP than runners with ND <10 mm. Runners with a history of ERLP in the month previous to the start of the XC season were 12 times (OR=12.3, 95% CI=3.1-48.9) more likely to develop an in-season occurrence of ERLP. While PFE did not appear to be a risk factor in the development of ERLP in this group of collegiate XC runners, those with a ND greater than 10 mm may be at greater odds of incurring medial ERLP. 2b.
Prevalence of allergy and upper respiratory tract symptoms in runners of the London marathon.
Robson-Ansley, Paula; Howatson, Glyn; Tallent, Jamie; Mitcheson, Kelly; Walshe, Ian; Toms, Chris; DU Toit, George; Smith, Matt; Ansley, Les
2012-06-01
The prevalence of self-reported upper respiratory tract (URT) symptoms in athletes has been traditionally associated with opportunistic infection during the temporal suppression of immune function after prolonged exercise. There is little evidence for this, and a competing noninfectious hypothesis has been proposed, whereby the exercise-induced immune system modulations favor the development of atopy and allergic disease, which manifests as URT symptoms. The aim of this study was to examine the association between allergy and URT symptoms in runners after an endurance running event. Two hundred eight runners from the 2010 London Marathon completed the validated Allergy Questionnaire for Athletes (AQUA) and had serum analyzed for total and specific immunoglobulin E response to common inhalant allergens. Participants who completed the marathon and nonrunning controls who lived in the same household were asked to complete a diary on URT symptoms. Forty percent of runners had allergy as defined by both a positive AQUA and elevated specific immunoglobulin E. Forty-seven percent of runners experienced URT symptoms after the marathon. A positive AQUA was a significant predictor of postmarathon URT symptoms in runners. Only 19% of nonrunning controls reported symptoms. The prevalence of allergy in recreational marathon runners was similar to that in elite athletes and higher than that in the general population. There was a strong association between a positive AQUA and URT symptoms. The low proportion of households in which both runners and nonrunners were symptomatic suggests that the nature of symptoms may be allergic or inflammatory based rather than infectious. Allergy is a treatable condition, and its potential effect on performance and health may be avoided by accurate clinical diagnosis and management. Both athletes' and coaches' awareness of the potential implications of poorly managed allergy needs to be raised.
Half-marathon and full-marathon runners' hydration practices and perceptions.
O'Neal, Eric K; Wingo, Jonathan E; Richardson, Mark T; Leeper, James D; Neggers, Yasmine H; Bishop, Phil A
2011-01-01
The behaviors and beliefs of recreational runners with regard to hydration maintenance are not well elucidated. To examine which beverages runners choose to drink and why, negative performance and health experiences related to dehydration, and methods used to assess hydration status. Cross-sectional study. Marathon registration site. Men (n = 146) and women (n = 130) (age = 38.3 ± 11.3 years) registered for the 2010 Little Rock Half-Marathon or Full Marathon. A 23-item questionnaire was administered to runners when they picked up their race timing chips. Runners were separated into tertiles (Low, Mod, High) based on z scores derived from training volume, expected performance, and running experience. We used a 100-mm visual analog scale with anchors of 0 (never) and 100 (always). Total sample responses and comparisons between tertile groups for questionnaire items are presented. The High group (58±31) reported greater consumption of sport beverages in exercise environments than the Low (42 ± 35 mm) and Mod (39 ± 32 mm) groups (P < .05) and perceived sport beverages to be superior to water in meeting hydration needs (P < .05) and improving performance during runs greater than 1 hour (P < .05). Seventy percent of runners experienced 1 or more incidents in which they believed dehydration resulted in a major performance decrement, and 45% perceived dehydration to have resulted in adverse health effects. Twenty percent of runners reported monitoring their hydration status. Urine color was the method most often reported (7%), whereas only 2% reported measuring changes in body weight. Greater attention should be paid to informing runners of valid techniques to monitor hydration status and developing an appropriate individualized hydration strategy.
Half-Marathon and Full-Marathon Runners' Hydration Practices and Perceptions
O'Neal, Eric K.; Wingo, Jonathan E.; Richardson, Mark T.; Leeper, James D.; Neggers, Yasmine H.; Bishop, Phil A.
2011-01-01
Context: The behaviors and beliefs of recreational runners with regard to hydration maintenance are not well elucidated. Objective: To examine which beverages runners choose to drink and why, negative performance and health experiences related to dehydration, and methods used to assess hydration status. Design: Cross-sectional study. Setting: Marathon registration site. Patients or Other Participants: Men (n = 146) and women (n = 130) (age = 38.3 ± 11.3 years) registered for the 2010 Little Rock Half-Marathon or Full Marathon. Intervention(s): A 23-item questionnaire was administered to runners when they picked up their race timing chips. Main Outcome Measure(s): Runners were separated into tertiles (Low, Mod, High) based on z scores derived from training volume, expected performance, and running experience. We used a 100-mm visual analog scale with anchors of 0 (never) and 100 (always). Total sample responses and comparisons between tertile groups for questionnaire items are presented. Results: The High group (58±31) reported greater consumption of sport beverages in exercise environments than the Low (42 ± 35 mm) and Mod (39 ± 32 mm) groups (P < .05) and perceived sport beverages to be superior to water in meeting hydration needs (P < .05) and improving performance during runs greater than 1 hour (P < .05). Seventy percent of runners experienced 1 or more incidents in which they believed dehydration resulted in a major performance decrement, and 45% perceived dehydration to have resulted in adverse health effects. Twenty percent of runners reported monitoring their hydration status. Urine color was the method most often reported (7%), whereas only 2% reported measuring changes in body weight. Conclusions: Greater attention should be paid to informing runners of valid techniques to monitor hydration status and developing an appropriate individualized hydration strategy. PMID:22488182
Di Lodovico, Laura; Dubertret, Caroline; Ameller, Aurely
2018-02-01
Excessive exercise is frequently associated with eating disorders and may degenerate into exercise addiction. We still don't know whether runners at risk for eating disorders are at risk for exercise addiction. Our aim is to assess: 1) risk for exercise addiction in runners at risk for eating disorders and 2) socio-demographic, behavioral and psychological characteristics distinguishing runners at-risk from not-at-risk for eating disorders. We assessed risk for eating disorders and exercise addiction using the SCOFF questionnaire and the Exercise Addiction Inventory personality traits with the Big-Five Inventory Test, socio-demographic data, eating and training habits in a sample of 154 healthy runners. Twenty five subjects had a score of ≥2 at the SCOFF and were included in the group "at risk for eating disorders". In this group, we found a higher percentage of subjects at risk for exercise addiction (p=0.01) and higher average scores at the Exercise Addiction Inventory (p=0.01) than runners not at risk (N=136). Runners at risk were statistically younger (p=0.03), women (p=0.001), started running to lose weight more often (p=0.03), lost more kilos since affiliation in their running club (p=0.04), and were characterized by neurotic traits using the Big-Five-Inventory Test (p=3.10 -6 ). Screening for exercise addiction and mood disorders could lead to a more accurate management of runners at risk for eating disorders. Identifying vulnerable individuals will facilitate the prevention of eating disorders and preserve the benefits of sport practice. Copyright © 2018. Published by Elsevier Inc.
Hespanhol Junior, Luiz Carlos; Pena Costa, Leonardo Oliveira; Lopes, Alexandre Dias
2013-12-01
What is the incidence of running-related injuries (RRIs) in recreational runners? Which personal and training characteristics predict RRIs in recreational runners? Prospective cohort study. A total of 200 recreational runners answered a fortnightly online survey containing questions about their running routine, races, and presence of RRI. These runners were followed-up for a period of 12 weeks. The primary outcome of this study was running-related injury. The incidence of injuries was calculated taking into account the exposure to running and was expressed by RRI/1000 hours. The association between potential predictive factors and RRIs was estimated using generalised estimating equation models. A total of 84 RRIs were registered in 60 (31%) of the 191 recreational runners who completed all follow-up surveys. Of the injured runners 30% (n=18/60) developed two or more RRIs, with 5/18 (28%) being recurrences. The incidence of RRI was 10 RRI/1000 hours of running exposure. The main type of RRI observed was muscle injuries (30%, n=25/84). The knee was the most commonly affected anatomical region (19%, n=16/84). The variables associated with RRI were: previous RRI (OR 1.88, 95% CI 1.01 to 3.51), duration of training although the effect was very small (OR 1.01, 95% CI 1.00 to 1.02), speed training (OR 1.46, 95% CI 1.02 to 2.10), and interval training (OR 0.61, 95% CI 0.43 to 0.88). Physiotherapists should be aware and advise runners that past RRI and speed training are associated with increased risk of further RRI, while interval training is associated with lower risk, although these associations may not be causative. Copyright © 2013 Australian Physiotherapy Association. Published by Elsevier B.V. All rights reserved.
Gastrointestinal complaints in runners are not due to small intestinal bacterial overgrowth
2011-01-01
Background Gastrointestinal complaints are common among long distance runners. We hypothesised that small intestinal bacterial overgrowth (SIBO) is present in long distance runners frequently afflicted with gastrointestinal complaints. Findings Seven long distance runners (5 female, mean age 29.1 years) with gastrointestinal complaints during and immediately after exercise without known gastrointestinal diseases performed Glucose hydrogen breath tests for detection of SIBO one week after a lactose hydrogen breath test checking for lactose intolerance. The most frequent symptoms were diarrhea (5/7, 71%) and flatulence (6/7, 86%). The study was conducted at a laboratory. In none of the subjects a pathological hydrogen production was observed after the intake of glucose. Only in one athlete a pathological hydrogen production was measured after the intake of lactose suggesting lactose intolerance. Conclusions Gastrointestinal disorders in the examined long distance runners were not associated with small intestinal bacterial overgrowth. PMID:21794099
Genetic aspects of athletic performance: the African runners phenomenon.
Vancini, Rodrigo Luiz; Pesquero, João Bosco; Fachina, Rafael Júlio; Andrade, Marília Dos Santos; Borin, João Paulo; Montagner, Paulo César; de Lira, Claudio Andre Barbosa
2014-01-01
The current dominance of African runners in long-distance running is an intriguing phenomenon that highlights the close relationship between genetics and physical performance. Many factors in the interesting interaction between genotype and phenotype (eg, high cardiorespiratory fitness, higher hemoglobin concentration, good metabolic efficiency, muscle fiber composition, enzyme profile, diet, altitude training, and psychological aspects) have been proposed in the attempt to explain the extraordinary success of these runners. Increasing evidence shows that genetics may be a determining factor in physical and athletic performance. But, could this also be true for African long-distance runners? Based on this question, this brief review proposed the role of genetic factors (mitochondrial deoxyribonucleic acid, the Y chromosome, and the angiotensin-converting enzyme and the alpha-actinin-3 genes) in the amazing athletic performance observed in African runners, especially the Kenyans and Ethiopians, despite their environmental constraints.
Influence of the boundary conditions on the natural frequencies of a Francis turbine
NASA Astrophysics Data System (ADS)
Valentín, David; Ramos, David; Bossio, Matías; Presas, Alexandre; Egusquiza, Eduard; Valero, Carme
2016-11-01
Natural frequencies estimation of Francis turbines is of paramount importance in the stage of design in order to avoid vibration and resonance problems especially during transient events. Francis turbine runners are submerged in water and confined with small axial and radial gaps which considerably decrease their natural frequencies in comparison to the same structure in the air. Acoustic-structural FSI simulations have been used to evaluate the influence of these gaps. This model considers an entire prototype of a Francis turbine, including generator, shaft, runner and surrounding water. The radial gap between the runner and the static parts has been changed from the real configuration (about 0.04% the runner diameter) to 1% of the runner diameter to evaluate its influence on the machine natural frequencies. Mode-shapes and natural frequencies of the whole machine are discussed for all the boundary conditions tested.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-10
... catch limit (ACL). Therefore, NMFS closes the commercial sector for blue runner on December 10, 2012... CFR part 622. The commercial ACL for blue runner in the South Atlantic is 188,329 lb (85,425 kg... ACL for blue runner has been reached, or is projected to be reached, by filing a notification to that...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-14
... annual catch limit (ACL) on November 14, 2013. Therefore, NMFS closes the commercial sector for blue... Act (Magnuson- Stevens Act) by regulations at 50 CFR part 622. The commercial ACL for blue runner in... sector for blue runner when the commercial ACL for blue runner has been reached, or is projected to be...
Rehabilitation and return to running after lower limb stress fractures.
Liem, Brian C; Truswell, Hallie J; Harrast, Mark A
2013-01-01
Lower limb stress fractures are common injuries in runners. In terms of treatment, much of the medical literature has focused primarily on rest and cessation of running, but little has been written about the rehabilitation and functional progression of runners following a lower limb stress fracture. This article reviews the scientific evidence behind common rehabilitation concepts used for runners recovering from these injuries and also discusses sport-specific training modalities such as deep water running and antigravity treadmill training. Overall this article is intended to be a practical resource for clinicians to guide runners in functional rehabilitation and return to running following lower limb stress injury.
Development of a pump-turbine runner based on multiobjective optimization
NASA Astrophysics Data System (ADS)
Xuhe, W.; Baoshan, Z.; Lei, T.; Jie, Z.; Shuliang, C.
2014-03-01
As a key component of reversible pump-turbine unit, pump-turbine runner rotates at pump or turbine direction according to the demand of power grid, so higher efficiencies under both operating modes have great importance for energy saving. In the present paper, a multiobjective optimization design strategy, which includes 3D inverse design method, CFD calculations, response surface method (RSM) and multiobjective genetic algorithm (MOGA), is introduced to develop a model pump-turbine runner for middle-high head pumped storage plant. Parameters that controlling blade shape, such as blade loading and blade lean angle at high pressure side are chosen as input parameters, while runner efficiencies under both pump and turbine modes are selected as objective functions. In order to validate the availability of the optimization design system, one runner configuration from Pareto front is manufactured for experimental research. Test results show that the highest unit efficiency is 91.0% under turbine mode and 90.8% under pump mode for the designed runner, of which prototype efficiencies are 93.88% and 93.27% respectively. Viscous CFD calculations for full passage model are also conducted, which aim at finding out the hydraulic improvement from internal flow analyses.
Bade, Michael B.; Aaron, Katie
2016-01-01
ABSTRACT Background Clinicians are interested in the foot strike pattern (FSP) in runners because of the suggested relationship between the strike pattern and lower extremity injury. Purpose The purpose of this study was to assess the ability of collegiate cross-country runners and recreational runners to self-report their foot strike pattern during running. Study Design Cross-sectional Study Methods Twenty-three collegiate cross-country and 23 recreational runners voluntarily consented to participate. Inclusion criteria included running at least 18 miles per week, experience running on a treadmill, no history of lower extremity congenital or traumatic deformity, or acute injury three months prior to the start of the study. All participants completed a pre-test survey to indicate their typical foot strike pattern during a training run (FSPSurvey). Prior to running, reflective markers were placed on the posterior midsole and the vamp of the running shoe. A high-speed camera was used to film each runner in standing and while running at his or her preferred speed on a treadmill. The angle between the vector formed by the two reflective markers and the superior surface of the treadmill was used to calculate the foot strike angle (FSA). To determine the foot strike pattern from the video data (FSPVideo), the static standing angle was subtracted from the FSA at initial contact of the shoe on the treadmill. In addition to descriptive statistics, percent agreement and Chi square analysis was used to determine distribution differences between the video analysis results and the survey. Results The results of the chi-square analysis on the distribution of the FSPSurvey in comparison to the FSPVideo were significantly different for both the XCRunners (p < .01; Chi-square = 8.77) and the REC Runners (p < .0002; Chi-square = 16.70). The cross-country and recreational runners could correctly self-identified their foot strike pattern 56.5% and 43.5% of the time, respectively. Conclusion The findings of this study suggest that the clinician cannot depend on an experienced runner to correctly self-identify their FSP. Clinicians interested in knowing the FSP of a runner should consider performing the two-dimensional video analysis described in this paper. Level of Evidence 3 PMID:27274421
Janssen, Mark; Scheerder, Jeroen; Thibaut, Erik; Brombacher, Aarnout; Vos, Steven
2017-01-01
Individual and unorganized sports with a health-related focus, such as recreational running, have grown extensively in the last decade. Consistent with this development, there has been an exponential increase in the availability and use of electronic monitoring devices such as smartphone applications (apps) and sports watches. These electronic devices could provide support and monitoring for unorganized runners, who have no access to professional trainers and coaches. The purpose of this paper is to gain insight into the characteristics of event runners who use running-related apps and sports watches. This knowledge is useful from research, design, and marketing perspectives to adequately address unorganized runners' needs, and to support them in healthy and sustainable running through personalized technology. Data used in this study are drawn from the standardized online Eindhoven Running Survey 2014 (ERS14). In total, 2,172 participants in the Half Marathon Eindhoven 2014 completed the questionnaire (a response rate of 40.0%). Binary logistic regressions were used to analyze the impact of socio-demographic variables, running-related variables, and psychographic characteristics on the use of running-related apps and sports watches. Next, consumer profiles were identified. The results indicate that the use of monitoring devices is affected by socio-demographics as well as sports-related and psychographic variables, and this relationship depends on the type of monitoring device. Therefore, distinctive consumer profiles have been developed to provide a tool for designers and manufacturers of electronic running-related devices to better target (unorganized) runners' needs through personalized and differentiated approaches. Apps are more likely to be used by younger, less experienced and involved runners. Hence, apps have the potential to target this group of novice, less trained, and unorganized runners. In contrast, sports watches are more likely to be used by a different group of runners, older and more experienced runners with higher involvement. Although apps and sports watches may potentially promote and stimulate sports participation, these electronic devices do require a more differentiated approach to target specific needs of runners. Considerable efforts in terms of personalization and tailoring have to be made to develop the full potential of these electronic devices as drivers for healthy and sustainable sports participation.
Influence of the rotor-stator interaction on the dynamic stresses of Francis runners
NASA Astrophysics Data System (ADS)
Guillaume, R.; Deniau, J. L.; Scolaro, D.; Colombet, C.
2012-11-01
Thanks to advances in computing capabilities and Computational Fluid Dynamics (CFD) techniques, it is now possible to calculate realistic unsteady pressure fields in Francis turbines. This paper will explain methods to calculate the structural loads and the dynamic behaviour in order to optimize the turbine design and maximize its reliability and lifetime. Depending on the operating conditions of a Francis turbine, different hydraulic phenomena may impact the mechanical behaviour of the structure. According to their nature, these highly variable phenomena should be treated differently and specifically in order to estimate the potential risks arising on submerged structures, in particular the runner. The operating condition studied thereafter is the point at maximum power with the maximum head. Under this condition, the runner is excited by only one dynamic phenomenon named the Rotor-Stator Interaction (RSI). The origin of the phenomenon is located on the radial gap of the turbine and is the source of pressure fluctuations. A fluid-structure analysis is performed to observe the influence of that dynamic pressure field on the runner behaviour. The first part of the paper deals with the unsteady fluid computation. The RSI phenomenon is totally unsteady so the fluid simulation must take into account the entire machine and its rotation movement, in order to obtain a dynamic pressure field. In the second part of the paper, a method suitable for the RSI study is developed. It is known that the fluctuating pressure in this gap can be described as a sum of spatial components. By evaluating these components in the CFD results and on the scale model, it is possible to assess the relevance of the numerical results on the whole runner. After this step, the numerical pressure field can be used as the dynamic load of the structure. The final part of the paper presentsthe mechanical finite element calculations. A modal analysis of the runner in water and a harmonic analysis of its dynamic behaviour using the CFD results are carried out. These calculations will show that the RSI on the medium head Francis runner does not create damage on the runner even if the natural frequencies are closed to the wicket gates passing frequency. The numerical results are reinforced by experimental observations done on runner prototypes showing that the wicket gates passing frequency does not have significant influence on low and medium head Francis runner behaviour.
Coarsening dynamics of binary liquids with active rotation.
Sabrina, Syeda; Spellings, Matthew; Glotzer, Sharon C; Bishop, Kyle J M
2015-11-21
Active matter comprised of many self-driven units can exhibit emergent collective behaviors such as pattern formation and phase separation in both biological (e.g., mussel beds) and synthetic (e.g., colloidal swimmers) systems. While these behaviors are increasingly well understood for ensembles of linearly self-propelled "particles", less is known about the collective behaviors of active rotating particles where energy input at the particle level gives rise to rotational particle motion. A recent simulation study revealed that active rotation can induce phase separation in mixtures of counter-rotating particles in 2D. In contrast to that of linearly self-propelled particles, the phase separation of counter-rotating fluids is accompanied by steady convective flows that originate at the fluid-fluid interface. Here, we investigate the influence of these flows on the coarsening dynamics of actively rotating binary liquids using a phenomenological, hydrodynamic model that combines a Cahn-Hilliard equation for the fluid composition with a Navier-Stokes equation for the fluid velocity. The effect of active rotation is introduced though an additional force within the Navier-Stokes equations that arises due to gradients in the concentrations of clockwise and counter-clockwise rotating particles. Depending on the strength of active rotation and that of frictional interactions with the stationary surroundings, we observe and explain new dynamical behaviors such as "active coarsening" via self-generated flows as well as the emergence of self-propelled "vortex doublets". We confirm that many of the qualitative behaviors identified by the continuum model can also be found in discrete, particle-based simulations of actively rotating liquids. Our results highlight further opportunities for achieving complex dissipative structures in active materials subject to distributed actuation.
Nurse, Victoria; Wright, Caradee Y; Allen, Martin; McKenzie, Richard L
2015-01-01
Marathon runners spend considerable time in outdoor training for and participating in marathons. Outdoor runners may experience high solar ultraviolet radiation (UVR) exposure. South Africa, where running is popular, experiences high ambient solar UVR levels that may be associated with adverse health effects. This feasibility study explores the use of personal dosimeters to determine solar UVR exposure patterns and possible related acute health risks of four marathon runners during marathons and training sessions in Cape Town and Pretoria. Runners running marathons that started early in the day, and that did not exceed 4 hours, yielded low total solar UVR exposure doses (mean 0.093 SED per exposure period run, median 0.088 SED, range 0.062-0.136 SED; average of 16.54% of ambient solar UVR). Training sessions run during early morning and late afternoon presented similar results. Several challenges hindered analysis including accounting for anatomical position of personal dosimeter and natural shade. To assess health risks, hazard quotients (HQs) were calculated using a hypothetical runner's schedule. Cumulative, annual solar UVR exposure-calculated acute health risks were low (HQ = 0.024) for training sessions and moderate (HQ = 4.922) for marathon runs. While these data and calculations are based on 18 person-days, one can measure marathon runners' personal solar UVR exposure although several challenges must be overcome. © 2015 The American Society of Photobiology.
Lucas-Cuevas, Angel Gabriel; Priego Quesada, José Ignacio; Giménez, José Vicente; Aparicio, Inma; Jimenez-Perez, Irene; Pérez-Soriano, Pedro
2016-11-01
Runners tend to shift from a rearfoot to a forefoot strike pattern when running barefoot. However, it is unclear how the first attempts at running barefoot affect habitually rearfoot shod runners. Due to the inconsistency of their recently adopted barefoot technique, a number of new barefoot-related running injuries are emerging among novice barefoot runners. The aim of this study was therefore to analyse the influence of three running conditions (natural barefoot [BF], barefoot with a forced rearfoot strike [BRS], and shod [SH]) on muscle activity and impact accelerations in habitually rearfoot shod runners. Twenty-two participants ran at 60% of their maximal aerobic speed while foot strike, tibial and head impact accelerations, and tibialis anterior (TA), peroneus longus (PL), gastrocnemius medialis (GM) and gastrocnemius lateralis (GL) muscle activity were registered. Only 68% of the runners adopted a non-rearfoot strike pattern during BF. Running BF led to a reduction of TA activity as well as to an increase of GL and GM activity compared to BRS and SH. Furthermore, BRS increased tibial peak acceleration, tibial magnitude and tibial acceleration rate compared to SH and BF. In conclusion, 32% of our runners showed a rearfoot strike pattern at the first attempts at running barefoot, which corresponds to a running style (BRS) that led to increased muscle activation and impact accelerations and thereby to a potentially higher risk of injury compared to running shod.
Liao, Tzu-Chieh; Keyak, Joyce H; Powers, Christopher M
2018-02-27
The purpose of this study is to determine whether recreational runners with patellofemoral pain (PFP) exhibit greater peak patella cartilage stress compared to pain-free runners. A secondary purpose was to determine the kinematic and/or kinetic predictors of peak patella cartilage stress during running. Twenty-two female recreational runners participated (12 with PFP and 10 pain-free controls). Patella cartilage stress profiles were quantified using subject-specific finite element models simulating the maximum knee flexion angle during stance phase of running. Input parameters to the finite element model included subject-specific patellofemoral joint geometry, quadriceps muscle forces, and lower extremity kinematics in the frontal and transverse planes. Tibiofemoral joint kinematics and kinetics were quantified to determine the best predictor of stress using stepwise regression analysis. Compared to the pain-free runners, those with PFP exhibited greater peak hydrostatic pressure (PFP vs. control, 21.2 ± 5.6 MPa vs. 16.5 ± 4.6 MPa) and maximum shear stress (11.3 ± 4.6 MPa vs. 8.7 ± 2.3 MPa). Knee external rotation was the best predictor of peak hydrostatic pressure and peak maximum shear stress (38% and 25% of variances, respectively) followed by the knee extensor moment (21% and 25% of variances, respectively). Runners with PFP exhibit greater peak patella cartilage stress during running compared to pain-free individuals. The combination of knee external rotation and a high knee extensor moment best predicted elevated peak stress during running.
[Diseases and overuse injuries of the lower extremities in long distance runners].
Tschopp, M; Brunner, F
2017-06-01
Running is one of the most popular sports worldwide, with running events attracting hundreds of thousands of runners of all age groups. Running is an effective way to improve health but is also associated with a high risk of injuries. Up to 50% of regular runners report having more than one injury each year. Some injuries are caused by an accident but most are caused by overuse. The most frequent diagnoses are patellofemoral pain syndrome, tibial stress syndrome (shin splint), Achilles tendinopathy, iliotibial band friction syndrome (runner's knee), plantar fasciitis and stress fractures of the metatarsals and tibia. The knee is the most frequently injured joint in runners at all distances. Hamstring injuries are typically acute resulting in a sudden, sharp pain in the posterior thigh. Hip injuries are less common but it can be more difficult to make the correct diagnosis and treatment is more complex. Clinicians confronted by runners with shin pain must distinguish between stress fractures of the tibia, tibial stress syndrome (shin splints) and chronic exertional compartment syndrome. Foot and ankle injuries are the most common injuries reported by long distance and marathon runners. Excess body weight and the number of kilometers run per week are high risk factors for injuries. The roles of other factors, such as shoes, stretching and biomechanics are less clear. A detailed anamnesis and physical examination are important for the correct diagnosis or the necessity for further diagnostic imaging and subsequent therapy.
Examining injury risk and pain perception in runners using minimalist footwear.
Ryan, Michael; Elashi, Maha; Newsham-West, Richard; Taunton, Jack
2014-08-01
This study examines the effect of progressive increases in footwear minimalism on injury incidence and pain perception in recreational runners. One hundred and three runners with neutral or mild pronation were randomly assigned a neutral (Nike Pegasus 28), partial minimalist (Nike Free 3.0 V2) or full minimalist shoe (Vibram 5-Finger Bikila). Runners underwent baseline testing to record training and injury history, as well as selected anthropometric measurements, before starting a 12-week training programme in preparation for a 10 km event. Outcome measures included number of injury events, Foot and Ankle Disability (FADI) scores and visual analogue scale pain rating scales for regional and overall pain with running. 99 runners were included in final analysis with 23 injuries reported; the neutral shoe reporting the fewest injuries (4) and the partial minimalist shoe (12) the most. The partial minimalist shoe reported a significantly higher rate of injury incidence throughout the 12-week period. Runners in the full minimalist group reported greater shin and calf pain. Running in minimalist footwear appears to increase the likelihood of experiencing an injury, with full minimalist designs specifically increasing pain at the shin and calf. Clinicians should exercise caution when recommending minimalist footwear to runners otherwise new to this footwear category who are preparing for a 10 km event. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-03
.... APHIS-2010-0101] RIN 0579-AD39 Importation of French Beans and Runner Beans From the Republic of Kenya.... SUMMARY: We are amending the fruits and vegetables regulations to allow the importation of French beans and runner beans from the Republic of Kenya into the United States. As a condition of entry, both...
Baker, Robert L; Souza, Richard B; Rauh, Mitchell J; Fredericson, Michael; Rosenthal, Michael D
2018-04-26
Iliotibial band syndrome has been associated with altered hip and knee kinematics in runners. Previous studies have recommended further research on neuromuscular factors at the hip. The frontal plane hip muscles have been a strong focus in strength comparison but not for electromyography investigation. To compare hip surface electromyography, and frontal plane hip and knee kinematics, in runners with and without iliotibial band syndrome. Observational cross-sectional study. Thirty participants were tested for motion capture at the hip and knee and muscle activation in the lateral and posterior hip. Biomechanics research laboratory within a university. Thirty subjects were recruited consisting of 15 injured runners with iliotibial band syndrome and 15 gender-, age-, and body mass index-matched controls. In each group, 8 were male runners and 7 were female runners. Inclusion criteria for the injured group were pain within 2 months related to iliotibial band syndrome and a positive Noble compression test. Participants were excluded if they reported other lower extremity diagnoses within the last year or active lower extremity or low back pain not related to iliotibial band syndrome. Controls were excluded if they reported a history of iliotibial band syndrome. Convenience sampling was used based on referrals from local running clinics and orthopedic clinics. Three-dimensional motion capture was performed with 10 high-speed cameras synchronized with wireless surface electromyography during a 30-minute run. The first data point was at 3 minutes, using a constant speed of 2.74 meters per second. A second data point was at 30 minutes, using a self-selected pace by the participant to allow for a challenging run until completion at 30 minutes. Motion capture was reported as peak kinematic values from heel strike to peak knee flexion for hip adduction and knee adduction. Surface electromyography was reported as a percentage of maximal voluntary contraction for the gluteus maximus, gluteus medius and tensor fascia latae muscles. Injured runners demonstrated increased knee adduction compared with control runners at 30 minutes (P = .002, control = -1.48°, injured = 3.74°). Tensor fasciae latae muscle activation in injured runners was increased compared with control runners at 3 minutes (P = .017, control = 7% maximal voluntary isometric contraction, injured = 11% maximal voluntary isometric contraction). The results of this study suggest that lateral knee pain in runners localized to the distal iliotibial band is associated with increased knee adduction at 30 minutes. Increased tensor fasciae latae muscle activation at three minutes is noted, but more investigation is needed to better understand the clinical meaning. These findings are consistent with but not conclusive evidence supporting the theory that neuromuscular factors of the hip muscles may contribute to increased knee adduction in runners with iliotibial band syndrome. We advise caution using these findings to support treatments intended to modify tensor fasciae latae activation, given the small differences of 4% in muscle activation. Increased knee adduction in runners at 30 minutes was over 5° and beyond the minimal detectable difference. Additional research is needed to confirm whether the degree of knee adduction changes earlier versus later in a run and whether fatigue is a clinically relevant factor. To be determined. Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Mechanism study on pressure fluctuation of pump-turbine runner with large blade lean angle
NASA Astrophysics Data System (ADS)
Yulin, Fan; Xuhe, Wang; Baoshan, Zhu; Dongyue, Zhou; Xijun, Zhou
2016-11-01
Excessive pressure fluctuations in the vaneless space can cause mechanical vibration and even mechanical failures in pump-turbine operation. Mechanism studies on the pressure fluctuations and optimization design of blade geometry to reduce the pressure fluctuations have important significance in industrial production. In the present paper, two pump-turbine runners with big positive and negative blade lean angle were designed by using a multiobjective design strategy. Model test showed that the runner with negative blade lean angle not only had better power performance, but also had lower pressure fluctuation than the runner with positive blade lean angle. In order to figure out the mechanism of pressure fluctuation reduction in the vaneless;jik8space, full passage model for both runners were built and transient CFD computations were conducted to simulate the flow states inside the channel. Detailed flow field analyses indicated that the difference of low-pressure area in the trailing edge of blade pressure side were the main causes of pressure fluctuation reduction in the vaneless space.
NASA Astrophysics Data System (ADS)
Lama, R.; Dahal, D. R.; Gautam, S.; Acharya, N.; Neopane, H.; Thapa, B. S.
2018-06-01
Francis turbine are ideal turbines for Himalayan and Andes region where both low and high-altitude mountains are located. Turbines operating in such regions face operational and maintenance problems due to the sediment erosion. In order to reduce the erosion effects on these components the design of components for higher sediment handling is essence. This paper presents performance analysis of Francis runner and prediction of sediment erosion on the runner blades for different operating conditions with different guide vane profiles. The simulations were carried out for 11 guide vane opening angles using Tabakoff erosion model. At full load and best efficiency point the erosion was localized at pressure side of runner blades outlet due to higher relative velocity. On the other hand, at part load condition, erosion was observed at suction side of the blades. Application of asymmetric guide vane profile NACA 4412 showed higher efficiency for all operating conditions with minimum erosion on runner blades in compare to symmetric guide vane profile NACA 0012.
Bex, T; Iannaccone, F; Stautemas, J; Baguet, A; De Beule, M; Verhegghe, B; Aerts, P; De Clercq, D; Derave, W
2017-03-01
Excellence in either sprinting or endurance running requires specific musculo-skeletal characteristics of the legs. This study aims to investigate the morphology of the leg of sprinters and endurance runners of Caucasian ethnicity. Eight male sprinters and 11 male endurance runners volunteered to participate in this cross-sectional study. They underwent magnetic resonance imaging and after data collection, digital reconstruction was done to calculate muscle volumes and bone lengths. Sprinters have a higher total upper leg volume compared to endurance runners (7340 vs 6265 cm 3 ). Specifically, the rectus femoris, vastus lateralis, and hamstrings showed significantly higher muscle volumes in the sprint group. For the lower leg, only a higher muscle volume was found in the gastrocnemius lateralis for the sprinters. No differences were found in muscle volume distribution, center of mass in the different muscles, or relative bone lengths. There was a significant positive correlation between ratio hamstrings/quadriceps volume and best running performance in the sprint group. Sprinters and endurance runners of Caucasian ethnicity showed the greatest distinctions in muscle volumes, rather than in muscle distributions or skeletal measures. Sprinters show higher volumes in mainly the proximal and lateral leg muscles than endurance runners. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Design optimization of axial flow hydraulic turbine runner: Part I - an improved Q3D inverse method
NASA Astrophysics Data System (ADS)
Peng, Guoyi; Cao, Shuliang; Ishizuka, Masaru; Hayama, Shinji
2002-06-01
With the aim of constructing a comprehensive design optimization procedure of axial flow hydraulic turbine, an improved quasi-three-dimensional inverse method has been proposed from the viewpoint of system and a set of rotational flow governing equations as well as a blade geometry design equation has been derived. The computation domain is firstly taken from the inlet of guide vane to the far outlet of runner blade in the inverse method and flows in different regions are solved simultaneously. So the influence of wicket gate parameters on the runner blade design can be considered and the difficulty to define the flow condition at the runner blade inlet is surmounted. As a pre-computation of initial blade design on S2m surface is newly adopted, the iteration of S1 and S2m surfaces has been reduced greatly and the convergence of inverse computation has been improved. The present model has been applied to the inverse computation of a Kaplan turbine runner. Experimental results and the direct flow analysis have proved the validation of inverse computation. Numerical investigations show that a proper enlargement of guide vane distribution diameter is advantageous to improve the performance of axial hydraulic turbine runner. Copyright
NASA Astrophysics Data System (ADS)
Peng, Guoyi; Cao, Shuliang; Ishizuka, Masaru; Hayama, Shinji
2002-06-01
This paper is concerned with the design optimization of axial flow hydraulic turbine runner blade geometry. In order to obtain a better design plan with good performance, a new comprehensive performance optimization procedure has been presented by combining a multi-variable multi-objective constrained optimization model with a Q3D inverse computation and a performance prediction procedure. With careful analysis of the inverse design of axial hydraulic turbine runner, the total hydraulic loss and the cavitation coefficient are taken as optimization objectives and a comprehensive objective function is defined using the weight factors. Parameters of a newly proposed blade bound circulation distribution function and parameters describing positions of blade leading and training edges in the meridional flow passage are taken as optimization variables.The optimization procedure has been applied to the design optimization of a Kaplan runner with specific speed of 440 kW. Numerical results show that the performance of designed runner is successfully improved through optimization computation. The optimization model is found to be validated and it has the feature of good convergence. With the multi-objective optimization model, it is possible to control the performance of designed runner by adjusting the value of weight factors defining the comprehensive objective function. Copyright
Melcher, Daniel A; Paquette, Max R; Schilling, Brian K; Bloomer, Richard J
2017-12-01
Research has focused on the effects of acute strike pattern modifications on lower extremity joint stiffness and running economy (RE). Strike pattern modifications on running biomechanics have mostly been studied while runners complete short running bouts. This study examined the effects of an imposed forefoot strike (FFS) on RE and ankle and knee joint stiffness before and after a long run in habitual rearfoot strike (RFS) runners. Joint kinetics and RE were collected before and after a long run. Sagittal joint kinetics were computed from kinematic and ground reaction force data that were collected during over-ground running trials in 13 male runners. RE was measured during treadmill running. Knee flexion range of motion, knee extensor moment and ankle joint stiffness were lower while plantarflexor moment and knee joint stiffness were greater during imposed FFS compared with RFS. The long run did not influence the difference in ankle and knee joint stiffness between strike patterns. Runners were more economical during RFS than imposed FFS and RE was not influenced by the long run. These findings suggest that using a FFS pattern towards the end of a long run may not be mechanically or metabolically beneficial for well-trained male RFS runners.
Isokinetic analysis of ankle and ground reaction forces in runners and triathletes
Luna, Natália Mariana Silva; Alonso, Angelica Castilho; Brech, Guilherme Carlos; Mochizuki, Luis; Nakano, Eduardo Yoshio; Greve, Júlia Maria D'Andréa
2012-01-01
OBJECTIVE: To analyze and compare the vertical component of ground reaction forces and isokinetic muscle parameters for plantar flexion and dorsiflexion of the ankle between long-distance runners, triathletes, and non-athletes. METHODS: Seventy-five males with a mean age of 30.26 (±6.5) years were divided into three groups: a triathlete group (n = 26), a long-distance runner group (n = 23), and a non-athlete control group. The kinetic parameters were measured during running using a force platform, and the isokinetic parameters were measured using an isokinetic dynamometer. RESULTS: The non-athlete control group and the triathlete group exhibited smaller vertical forces, a greater ground contact time, and a greater application of force during maximum vertical acceleration than the long-distance runner group. The total work (180°/s) was greater in eccentric dorsiflexion and concentric plantar flexion for the non-athlete control group and the triathlete group than the long-distance runner group. The peak torque (60°/s) was greater in eccentric plantar flexion and concentric dorsiflexion for the control group than the athlete groups. CONCLUSIONS: The athlete groups exhibited less muscle strength and resistance than the control group, and the triathletes exhibited less impact and better endurance performance than the runners. PMID:23018298
Ribeiro, Ana Paula; Trombini-Souza, Francis; Tessutti, Vitor; Lima, Fernanda Rodrigues; de Camargo Neves Sacco, Isabel; João, Sílvia Maria Amado
2011-01-01
OBJECTIVE: To evaluate and compare rearfoot alignment and medial longitudinal arch index during static postures in runners, with and without symptoms and histories of plantar fasciitis (PF). INTRODUCTION: PF is the third most common injury in runners but, so far, its etiology remains unclear. In the literature, rearfoot misalignment and conformations of the longitudinal plantar arch have been described as risk factors for the development of PF. However, in most of the investigated literature, the results are still controversial, mainly regarding athletic individuals and the effects of pain associated with these injuries. METHODS: Forty-five runners with plantar fasciitis (30 symptomatic and 15 with previous histories of injuries) and 60 controls were evaluated. Pain was assessed by a visual analogue scale. The assessment of rearfoot alignment and the calculations of the arch index were performed by digital photographic images. RESULTS: There were observed similarities between the three groups regarding the misalignments of the rearfoot valgus. The medial longitudinal arches were more elevated in the group with symptoms and histories of PF, compared to the control runners. CONCLUSIONS: Runners with symptoms or histories of PF did not differ in rearfoot valgus misalignments, but showed increases in the longitudinal plantar arch during bipedal static stance, regardless of the presence of pain symptoms. PMID:21808870
Body Weight, Serum Sodium Levels, and Renal Function in an Ultra-Distance Mountain Run.
Scotney, Bianca; Reid, Steve
2015-07-01
To determine body weight and serum [Na] changes in runners completing an 85-km mountain run, particularly with reference to their "in-race" hydration protocols. Prospective observational cohort study. Cradle Mountain Run, Tasmania, Australia, February 2011. Forty-four runners (86% of starters) prospectively enrolled, with 41 runners (80% of starters) eligible for inclusion in final data set. Body weight change, serum sodium concentration change, and hydration plan (according to thirst vs preplanned fluid consumption). There was 1 case of exercise-associated hyponatremia (EAH) [postrace [Na], 132 mmol/L]. This runner was asymptomatic. There was a strongly significant correlation between the change in serum [Na] and body weight change during the race. There was a significant inverse correlation between serum [Na] and volume of fluid consumed. Change of serum [Na] was not correlated with the proportion of water versus electrolyte drink consumed. Runners drinking to thirst consumed significantly lower average fluid volumes and had higher postrace serum [Na] than those complying with a preplanned hydration protocol (142 mmol/L vs 139 mmol/L). More experienced runners tended to drink to thirst. There was a 2% incidence of EAH in this study. Serum [Na] change during an 85-km mountain run was inversely correlated with the volume of fluid consumed. The results provide further evidence that EAH is a dilutional hyponatremia caused by excessive consumption of hypotonic fluids. Drinking to thirst represents a safe hydration strategy for runners in a wilderness environment. Drinking to thirst during endurance running events should be promoted as a safe hydration practice.
Long-Term Marathon Running Is Associated with Low Coronary Plaque Formation in Women.
Roberts, William O; Schwartz, Robert S; Kraus, Stacia Merkel; Schwartz, Jonathan G; Peichel, Gretchen; Garberich, Ross F; Lesser, John R; Oesterle, Stephen N; Wickstrom, Kelly K; Knickelbine, Thomas; Harris, Kevin M
2017-04-01
Marathon running is presumed to improve cardiovascular risk, but health benefits of high volume running are unknown. High-resolution coronary computed tomography angiography and cardiac risk factor assessment were completed in women with long-term marathon running histories to compare to sedentary women with similar risk factors. Women who had run at least one marathon per year for 10-25 yr underwent coronary computed tomography angiography, 12-lead ECG, blood pressure and heart rate measurement, lipid panel, and a demographic/health risk factor survey. Sedentary matched controls were derived from a contemporaneous clinical study database. CT scans were analyzed for calcified and noncalcified plaque prevalence, volume, stenosis severity, and calcium score. Women marathon runners (n = 26), age 42-82 yr, with combined 1217 marathons (average 47) exhibited significantly lower coronary plaque prevalence and less calcific plaque volume. The marathon runners also had less risk factors (smoking, hypertension, and hyperlipidemia); significantly lower resting heart rate, body weight, body mass index, and triglyceride levels; and higher high-density lipoprotein cholesterol levels compared with controls (n = 28). The five women runners with coronary plaque had run marathons for more years and were on average 12 yr older (65 vs 53) than the runners without plaque. Women marathon runners had minimal coronary artery calcium counts, lower coronary artery plaque prevalence, and less calcified plaque volume compared with sedentary women. Developing coronary artery plaque in long-term women marathon runners appears related to older age and more cardiac risk factors, although the runners with coronary artery plaque had accumulated significantly more years running marathons.
RUNNING INJURY DEVELOPMENT: THE ATTITUDES OF MIDDLE- AND LONG-DISTANCE RUNNERS AND THEIR COACHES.
Johansen, Karen Krogh; Hulme, Adam; Damsted, Camma; Ramskov, Daniel; Nielsen, Rasmus Oestergaard
2017-08-01
Behavioral science methods have rarely been used in running injury research. Therefore, the attitudes amongst runners and their coaches regarding factors leading to running injuries warrants formal investigation. To investigate the attitudes of middle- and long-distance runners able to compete in national championships and their coaches about factors associated with running injury development. A link to an online survey was distributed to middle- and long-distance runners and their coaches across 25 Danish Athletics Clubs. The main research question was: "Which factors do you believe influence the risk of running injuries?". In response to this question, the athletes and coaches had to click "Yes" or "No" to 19 predefined factors. In addition, they had the possibility to submit a free-text response. A total of 68 athletes and 19 coaches were included in the study. A majority of the athletes (76% [95%CI: 66%; 86%]) and coaches (79% [95%CI: 61%; 97%]) reported "Ignoring pain" as a risk factor for running injury. A majority of the coaches reported "Reduced muscle strength" (79% [95%CI: 61%; 97%]) and "high running distance" (74% [95%CI: 54%; 94%]) to be associated with injury, while half of the runners found "insufficient recovery between running sessions" (53% [95%CI: 47%; 71%]) important. Runners and their coaches emphasize ignoring pain as a factor associated with injury development. The question remains how much running, if any at all, runners having slight symptoms or mild pain, are able to tolerate before these symptoms develop into a running-related injury. 3b.
libRoadRunner: a high performance SBML simulation and analysis library
Somogyi, Endre T.; Bouteiller, Jean-Marie; Glazier, James A.; König, Matthias; Medley, J. Kyle; Swat, Maciej H.; Sauro, Herbert M.
2015-01-01
Motivation: This article presents libRoadRunner, an extensible, high-performance, cross-platform, open-source software library for the simulation and analysis of models expressed using Systems Biology Markup Language (SBML). SBML is the most widely used standard for representing dynamic networks, especially biochemical networks. libRoadRunner is fast enough to support large-scale problems such as tissue models, studies that require large numbers of repeated runs and interactive simulations. Results: libRoadRunner is a self-contained library, able to run both as a component inside other tools via its C++ and C bindings, and interactively through its Python interface. Its Python Application Programming Interface (API) is similar to the APIs of MATLAB (www.mathworks.com) and SciPy (http://www.scipy.org/), making it fast and easy to learn. libRoadRunner uses a custom Just-In-Time (JIT) compiler built on the widely used LLVM JIT compiler framework. It compiles SBML-specified models directly into native machine code for a variety of processors, making it appropriate for solving extremely large models or repeated runs. libRoadRunner is flexible, supporting the bulk of the SBML specification (except for delay and non-linear algebraic equations) including several SBML extensions (composition and distributions). It offers multiple deterministic and stochastic integrators, as well as tools for steady-state analysis, stability analysis and structural analysis of the stoichiometric matrix. Availability and implementation: libRoadRunner binary distributions are available for Mac OS X, Linux and Windows. The library is licensed under Apache License Version 2.0. libRoadRunner is also available for ARM-based computers such as the Raspberry Pi. http://www.libroadrunner.org provides online documentation, full build instructions, binaries and a git source repository. Contacts: hsauro@u.washington.edu or somogyie@indiana.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:26085503
Schwellnus, Martin P; Swanevelder, Sonja; Jordaan, Esme; Derman, Wayne; Van Rensburg, Dina C Janse
2018-05-01
Exercise-associated muscle cramping (EAMC) is a significant medical complication in distance runners, yet factors associated with EAMC are poorly documented. To document risk factors associated with EAMC in runners. Cross-sectional study. Two ocean races (21.1 km, and 56 km). Fifteen thousand seven hundred seventy-eight race entrants. Participants completed a prerace medical history screening tool including: training, cardiovascular disease (CVD), risk factors for, and symptoms of CVD, history of diseases affecting major organ systems, cancer, allergies, medication use, and running injury. Runners were grouped as having a history of EAMC (hEAMC group = 2997) and a control group (Control = 12 781). Independent factors associated with a higher prevalence ratio (PR) of hEAMC were any risk factor for CVD (PR = 1.16; P = 0.0002), symptoms of CVD (PR = 2.38; P < 0.0001), respiratory disease (PR = 1.33; P < 0.0001), gastrointestinal disease (PR = 1.86; P < 0.0001), nervous system or psychiatric disease (PR = 1.51; P < 0.0001), kidney or bladder disease, (PR = 1.60; P < 0.0001), haematological or immune disease (PR = 1.54; P = 0.0048), cancer (PR = 1.34; P = 0.0031), allergies (PR = 1.37; P < 0.0001), regular medication use (PR = 1.80; P < 0.0001), statin use (PR = 1.26; P = 0.0127), medication use during racing (PR = 1.88; P < 0.0001), running injury (PR = 1.66; P < 0.0001), muscle injury (PR = 1.82; P < 0.0001), tendon injury (PR = 1.62; P < 0.0001), and runners in the experienced category (PR = 1.22; P < 0.0001). Novel risk factors associated with EAMC in distance runners were underlying chronic disease, medication use, a history of running injuries, and experienced runners. These factors must be identified as possible associations, and therefore be considered in the diagnosis and treatment of EAMC.
Hoffman, Martin D; Krishnan, Eswar
2014-01-01
Regular exercise is associated with substantial health benefits; however, little is known about the health impact of extreme levels of exercise. This study examined the prevalence of chronic diseases, health-care utilization, and risk factors for exercise-related injuries among ultramarathon runners. Retrospective, self-reported enrollment data from an ongoing longitudinal observational study of 1,212 active ultramarathon runners were analyzed. The most prevalent chronic medical conditions were allergies/hay fever (25.1%) and exercise-induced asthma (13.0%), but there was a low prevalence of serious medical issues including cancers (4.5%), coronary artery disease (0.7%), seizure disorders (0.7%), diabetes (0.7%), and human immunodeficiency virus (HIV) infection (0.2%). In the year preceding enrollment, most (64.6%) reported an exercise-related injury that resulted in lost training days (median of 14 days), but little nonattendance of work or school due to illness, injury, or exercise-related medical conditions (medians of 0 days for each). The knee was the most common area of exercise-related injury. Prior year incidence of stress fractures was 5.5% with most (44.5%) involving the foot. Ultramarathon runners who sustained exercise-related injuries were younger (p<0.001) and less experienced (p<0.01) than those without injury. Stress fractures were more common (p<0.01) among women than men. We conclude that, compared with the general population, ultramarathon runners appear healthier and report fewer missed work or school days due to illness or injury. Ultramarathon runners have a higher prevalence of asthma and allergies than the general population, and the prevalence of serious medical issues was nontrivial and should be recognized by those providing medical care to these individuals. Ultramarathon runners, compared with shorter distance runners, have a similar annual incidence of exercise-related injuries but higher proportion of stress fractures involving the foot, and it is the younger and less experienced ultramarathoners who appear most at risk for injury.
libRoadRunner: a high performance SBML simulation and analysis library.
Somogyi, Endre T; Bouteiller, Jean-Marie; Glazier, James A; König, Matthias; Medley, J Kyle; Swat, Maciej H; Sauro, Herbert M
2015-10-15
This article presents libRoadRunner, an extensible, high-performance, cross-platform, open-source software library for the simulation and analysis of models expressed using Systems Biology Markup Language (SBML). SBML is the most widely used standard for representing dynamic networks, especially biochemical networks. libRoadRunner is fast enough to support large-scale problems such as tissue models, studies that require large numbers of repeated runs and interactive simulations. libRoadRunner is a self-contained library, able to run both as a component inside other tools via its C++ and C bindings, and interactively through its Python interface. Its Python Application Programming Interface (API) is similar to the APIs of MATLAB ( WWWMATHWORKSCOM: ) and SciPy ( HTTP//WWWSCIPYORG/: ), making it fast and easy to learn. libRoadRunner uses a custom Just-In-Time (JIT) compiler built on the widely used LLVM JIT compiler framework. It compiles SBML-specified models directly into native machine code for a variety of processors, making it appropriate for solving extremely large models or repeated runs. libRoadRunner is flexible, supporting the bulk of the SBML specification (except for delay and non-linear algebraic equations) including several SBML extensions (composition and distributions). It offers multiple deterministic and stochastic integrators, as well as tools for steady-state analysis, stability analysis and structural analysis of the stoichiometric matrix. libRoadRunner binary distributions are available for Mac OS X, Linux and Windows. The library is licensed under Apache License Version 2.0. libRoadRunner is also available for ARM-based computers such as the Raspberry Pi. http://www.libroadrunner.org provides online documentation, full build instructions, binaries and a git source repository. hsauro@u.washington.edu or somogyie@indiana.edu Supplementary data are available at Bioinformatics online. Published by Oxford University Press 2015. This work is written by US Government employees and is in the public domain in the US.
Reinking, Mark F.; Rauh, Mitchell J.
2012-01-01
Purpose: The purpose of this study was to examine the relationships between isotonic ankle plantar flexor endurance (PFE), foot pronation as measured by navicular drop, and exercise-related leg pain (ERLP). Background: Exercise-related leg pain is a common occurrence in competitive and recreational runners. The identification of factors contributing to the development of ERLP may help guide methods for the prevention and management of overuse injuries. Methods: Seventy-seven (44 males, 33 females) competitive runners from five collegiate cross-country (XC) teams consented to participate in the study. Isotonic ankle PFE and foot pronation were measured using the standing heel-rise and navicular drop (ND) tests, respectively. Demographic information, anthropometric measurements, and ERLP history were also recorded. Subjects were then prospectively tracked for occurrence of ERLP during the 2009 intercollegiate cross-country season. Multivariate logistic regression analysis was used to examine the relationships between isotonic ankle joint PFE and ND and the occurrence of ERLP. Results: While no significant differences were identified for isotonic ankle PFE between groups of collegiate XC runners with and without ERLP, runners with a ND >10 mm were almost 7 times (OR=6.6, 95% CI=1.2–38.0) more likely to incur medial ERLP than runners with ND <10 mm. Runners with a history of ERLP in the month previous to the start of the XC season were 12 times (OR=12.3, 95% CI=3.1–48.9) more likely to develop an in-season occurrence of ERLP. Conclusion: While PFE did not appear to be a risk factor in the development of ERLP in this group of collegiate XC runners, those with a ND greater than 10 mm may be at greater odds of incurring medial ERLP. Level of Evidence: 2b. PMID:22666641
2013-01-01
Background This study examined the changes in participation, performance and age of East African runners competing in half-marathons and marathons held in Switzerland between 2000 and 2010. Methods Race times, sex, age and origin of East African versus Non-African finishers of half-marathon and marathon finishers were analyzed. Results Across time, the number of Kenyan and Ethiopian finishers remained stable (P > 0.05) while the number of Non-African finishers increased for both women and men in both half-marathons and marathons (P < 0.05). In half-marathons, the top ten African women (71 ± 1.4 min) and top three (62.3 ± 0.6 min) and top ten (62.8 ± 0.4 min) African men were faster than their Non-African counterparts (P < 0.05). In marathons, however, there was no difference in race times between the top three African men (130.0 ± 0.0 min) and women (151.7 ± 2.5 min) compared to Non-African men (129.0 ± 1.0 min) and women (150.7 ± 1.2 min) (P > 0.05). In half-marathons and marathons was no difference in age between the best Non-African and the best African runners (P > 0.05). Conclusions During the last decade in Switzerland, the participation of Kenyan and Ethiopian runners in half- and full- marathons remained stable. In marathons there was no difference in age and performance between the top African and the top Non-African runners. Regarding half-marathons, the top African runners were faster but not younger than the top Non-African runners. Future insight should be gained by comparing the present results with participation, performance and age trends for East African runners competing in marathons held in larger countries. PMID:24289794
Improved marathon performance by in-race nutritional strategy intervention.
Hansen, Ernst Albin; Emanuelsen, Anders; Gertsen, Robert Mørkegaard; Sørensen S, S R
2014-12-01
It was tested whether a marathon was completed faster by applying a scientifically based rather than a freely chosen nutritional strategy. Furthermore, gastrointestinal symptoms were evaluated. Nonelite runners performed a 10 km time trial 7 weeks before Copenhagen Marathon 2013 for estimation of running ability. Based on the time, runners were divided into two similar groups that eventually should perform the marathon by applying the two nutritional strategies. Matched pairs design was applied. Before the marathon, runners were paired based on their prerace running ability. Runners applying the freely chosen nutritional strategy (n = 14; 33.6 ± 9.6 years; 1.83 ± 0.09 m; 77.4 ± 10.6 kg; 45:40 ± 4:32 min for 10 km) could freely choose their in-race intake. Runners applying the scientifically based nutritional strategy (n = 14; 41.9 ± 7.6 years; 1.79 ± 0.11 m; 74.6 ± 14.5 kg; 45:44 ± 4:37 min) were targeting a combined in-race intake of energy gels and water, where the total intake amounted to approximately 0.750 L water, 60 g maltodextrin and glucose, 0.06 g sodium, and 0.09 g caffeine per hr. Gastrointestinal symptoms were assessed by a self-administered postrace questionnaire. Marathon time was 3:49:26 ± 0:25:05 and 3:38:31 ± 0:24:54 hr for runners applying the freely chosen and the scientifically based strategy, respectively (p = .010, effect size=-0.43). Certain runners experienced diverse serious gastrointestinal symptoms, but overall, symptoms were low and not different between groups (p > .05). In conclusion, nonelite runners completed a marathon on average 10:55 min, corresponding to 4.7%, faster by applying a scientifically based rather than a freely chosen nutritional strategy. Furthermore, average values of gastrointestinal symptoms were low and not different between groups.
Adams, William M; Hosokawa, Yuri; Huggins, Robert A; Mazerolle, Stephanie M; Casa, Douglas J
2016-08-01
Evidence-based best practices for the recognition and treatment of exertional heat stroke (EHS) indicate that rectal thermometry and immediate, aggressive cooling via cold-water immersion ensure survival from this medical condition. However, little is known about the recovery, medical follow-up, and return to activity after an athlete has suffered EHS. To highlight the transfer of evidenced-based research into clinical practice by chronicling the treatment, recovery, and return to activity of a runner who suffered an EHS during a warm-weather road race. Case study. Warm-weather road race. 53-y-old recreationally active man. A runner's treatment, recovery, and return to activity from EHS and 2014 Falmouth Road Race performance. Runner's perceptions and experiences with EHS, body temperature, heart rate, hydration status, exercise intensity. The runner successfully completed the 2014 Falmouth Road Race without incident of EHS. Four dominant themes emerged from the data: predisposing factors, ideal treatment, lack of medical follow-up, and patient education. The first theme identified 3 predisposing factors that contributed to the runner's EHS: hydration, sleep loss, and lack of heat acclimatization. The runner received ideal treatment using evidence-based best practices. A lack of long-term medical care following the EHS with no guidance on the runner's return to full activity was observed. The runner knew very little about EHS before the 2013 race, which drove him to seek knowledge as to why he suffered EHS. Using this newly learned information, he successfully completed the 2014 Falmouth Road Race without incident. This case supports prior literature examining the factors that predispose individuals to EHS. Although evidence-based best practices regarding prompt recognition and treatment of EHS ensure survival, this case highlights the lack of medical follow-up and physician-guided return to activity after EHS.
Hoffman, Martin D.; Krishnan, Eswar
2014-01-01
Regular exercise is associated with substantial health benefits; however, little is known about the health impact of extreme levels of exercise. This study examined the prevalence of chronic diseases, health-care utilization, and risk factors for exercise-related injuries among ultramarathon runners. Retrospective, self-reported enrollment data from an ongoing longitudinal observational study of 1,212 active ultramarathon runners were analyzed. The most prevalent chronic medical conditions were allergies/hay fever (25.1%) and exercise-induced asthma (13.0%), but there was a low prevalence of serious medical issues including cancers (4.5%), coronary artery disease (0.7%), seizure disorders (0.7%), diabetes (0.7%), and human immunodeficiency virus (HIV) infection (0.2%). In the year preceding enrollment, most (64.6%) reported an exercise-related injury that resulted in lost training days (median of 14 days), but little nonattendance of work or school due to illness, injury, or exercise-related medical conditions (medians of 0 days for each). The knee was the most common area of exercise-related injury. Prior year incidence of stress fractures was 5.5% with most (44.5%) involving the foot. Ultramarathon runners who sustained exercise-related injuries were younger (p<0.001) and less experienced (p<0.01) than those without injury. Stress fractures were more common (p<0.01) among women than men. We conclude that, compared with the general population, ultramarathon runners appear healthier and report fewer missed work or school days due to illness or injury. Ultramarathon runners have a higher prevalence of asthma and allergies than the general population, and the prevalence of serious medical issues was nontrivial and should be recognized by those providing medical care to these individuals. Ultramarathon runners, compared with shorter distance runners, have a similar annual incidence of exercise-related injuries but higher proportion of stress fractures involving the foot, and it is the younger and less experienced ultramarathoners who appear most at risk for injury. PMID:24416176
Frequency-domain method for discrete frequency noise prediction of rotors in arbitrary steady motion
NASA Astrophysics Data System (ADS)
Gennaretti, M.; Testa, C.; Bernardini, G.
2012-12-01
A novel frequency-domain formulation for the prediction of the tonal noise emitted by rotors in arbitrary steady motion is presented. It is derived from Farassat's 'Formulation 1A', that is a time-domain boundary integral representation for the solution of the Ffowcs-Williams and Hawkings equation, and represents noise as harmonic response to body kinematics and aerodynamic loads via frequency-response-function matrices. The proposed frequency-domain solver is applicable to rotor configurations for which sound pressure levels of discrete tones are much higher than those of broadband noise. The numerical investigation concerns the analysis of noise produced by an advancing helicopter rotor in blade-vortex interaction conditions, as well as the examination of pressure disturbances radiated by the interaction of a marine propeller with a non-uniform inflow.
NASA Astrophysics Data System (ADS)
Eichhorn, M.; Taruffi, A.; Bauer, C.
2017-04-01
The operators of hydropower plants are forced to extend the existing operating ranges of their hydraulic machines to remain competitive on the energy market due to the rising amount of wind and solar power. Faster response times and a higher flexibility towards part- and low-load conditions enable a better electric grid control and assure therefore an economic operation of the power plant. The occurring disadvantage is a higher dynamic excitation of affected machine components, especially Francis turbine runners, due to pressure pulsations induced by unsteady flow phenomena (e.g. draft tube vortex ropes). Therefore, fatigue analysis becomes more important even in the design phase of the hydraulic machines to evaluate the static and dynamic load in different operating conditions and to reduce maintenance costs. An approach including a one-way coupled fluid-structure interaction has been already developed using unsteady CFD simulations and transient FEM computations. This is now applied on two Francis turbines with different specific speeds and power ranges, to obtain the load spectra of both machines. The results are compared to strain gauge measurements on the according Francis turbines to validate the overall procedure.
NASA Astrophysics Data System (ADS)
Weng, Hanli; Li, Youping
2017-04-01
The working principle, process device and test procedure of runner static balancing test method by weighting with three-pivot pressure transducers are introduced in this paper. Based on an actual instance of a V hydraulic turbine runner, the error and sensitivity of the three-pivot pressure transducer static balancing method are analysed. Suggestions about improving the accuracy and the application of the method are also proposed.
Minimalist shoe injuries: three case reports.
Cauthon, David J; Langer, Paul; Coniglione, Thomas C
2013-01-01
Running in minimalist shoes continues to increase in popularity and multiple mainstream shoe companies now offer minimalist shoes. While there is no evidence that traditional running shoes prevent injuries, there are concerns that the designs of minimalist shoes may increase injury risk. However, reports of injuries in runners wearing minimalist shoes are rare. We present three injuries occurring in runners that were wearing minimalist shoes at the time of injury. All three of the runners switched immediately to the minimalist shoes with no transition period. We recommend that any transition to minimalist shoe gear be performed gradually. It is our contention that these injuries are quite common and will continue to become more prevalent as more runners change to these shoes. Copyright © 2013. Published by Elsevier Ltd.
Iliotibial band syndrome in runners: a systematic review.
van der Worp, Maarten P; van der Horst, Nick; de Wijer, Anton; Backx, Frank J G; Nijhuis-van der Sanden, Maria W G
2012-11-01
The popularity of running is still growing and, as participation increases, the incidence of running-related injuries will also rise. Iliotibial band syndrome (ITBS) is the most common injury of the lateral side of the knee in runners, with an incidence estimated to be between 5% and 14%. In order to facilitate the evidence-based management of ITBS in runners, more needs to be learned about the aetiology, diagnosis and treatment of this injury. This article provides a systematic review of the literature on the aetiology, diagnosis and treatment of ITBS in runners. The Cochrane Library, MEDLINE, EMBASE, CINAHL, Web of Science, and reference lists were searched for relevant articles. Systematic reviews, clinical trials or observational studies involving adult runners (>18 years) that focused on the aetiology, diagnosis and/or treatment of ITBS were included and articles not written in English, French, German or Dutch were excluded. Two reviewers independently screened search results, assessed methodological quality and extracted data. The sum of all positive ratings divided by the maximum score was the percentage quality score (QS). Only studies with a QS higher than 60% were included in the analysis. The following data were extracted: study design; number and characteristics of participants; diagnostic criteria for ITBS; exposure/treatment characteristics; analyses/outcome variables of the study; and setting and theoretical perspective on ITBS. The studies of the aetiology of ITBS in runners provide limited or conflicting evidence and it is not clear whether hip abductor weakness has a major role in ITBS. The kinetics and kinematics of the hip, knee and/or ankle/foot appear to be considerably different in runners with ITBS to those without. The biomechanical studies involved small samples, and data seem to have been influenced by sex, height and weight of participants. Although most studies monitored the management of ITBS using clinical tests, these tests have not been validated for this patient group. While the articles were inconsistent regarding the treatment of ITBS, hip/knee coordination and running style appear to be key factors in the treatment of ITBS. Runners might also benefit from mobilization, exercises to strengthen the hip, and advice about running shoes and running surface. The methodological quality of research into the management of ITBS in runners is poor and the results are highly conflicting. Therefore, the study designs should be improved to prevent selection bias and to increase the generalizability of findings.
Dietary supplement usage and motivation in Brazilian road runners.
Salgado, José Vítor Vieira; Lollo, Pablo Christiano Barboza; Amaya-Farfan, Jaime; Chacon-Mikahil, Mara PatríciaTraina
2014-01-01
The consumption of dietary supplements is highest among athletes and it can represent potential a health risk for consumers. The aim of this study was to determine the prevalence of consumption of dietary supplements by road runners. We interviewed 817 volunteers from four road races in the Brazilian running calendar. The sample consisted of 671 male and 146 female runners with a mean age of 37.9 ± 12.4 years. Of the sample, 28.33% reported having used some type of dietary supplement. The main motivation for this consumption is to increase in stamina and improve performance. The probability of consuming dietary supplements increased 4.67 times when the runners were guided by coaches. The consumption of supplements was strongly correlated (r = 0.97) with weekly running distance, and also highly correlated (r = 0.86) with the number of years the sport had been practiced. The longer the runner had practiced the sport, the higher the training volume and the greater the intake of supplements. The five most frequently cited reasons for consumption were: energy enhancement (29.5%), performance improvement (17.1%), increased level of endurance (10.3%), nutrient replacement (11.1%), and avoidance of fatigue (10.3%). About 30% of the consumers declared more than one reason for taking dietary supplements. The most consumed supplements were: carbohydrates (52.17%), vitamins (28.70%), and proteins (13.48%). Supplement consumption by road runners in Brazil appeared to be guided by the energy boosting properties of the supplement, the influence of coaches, and the experience of the user. The amount of supplement intake seemed to be lower among road runners than for athletes of other sports. We recommend that coaches and nutritionists emphasise that a balanced diet can meet the needs of physically active people.
Malisoux, Laurent; Chambon, Nicolas; Delattre, Nicolas; Gueguen, Nils; Urhausen, Axel; Theisen, Daniel
2016-01-01
Background/aim This randomised controlled trial investigated if the usage of running shoes with a motion control system modifies injury risk in regular leisure-time runners compared to standard shoes, and if this influence depends on foot morphology. Methods Recreational runners (n=372) were given either the motion control or the standard version of a regular running shoe model and were followed up for 6 months regarding running activity and injury. Foot morphology was analysed using the Foot Posture Index method. Cox regression analyses were used to compare injury risk between the two groups, based on HRs and their 95% CIs, controlling for potential confounders. Stratified analyses were conducted to evaluate the effect of motion control system in runners with supinated, neutral and pronated feet. Results The overall injury risk was lower among the participants who had received motion control shoes (HR=0.55; 95% CI 0.36 to 0.85) compared to those receiving standard shoes. This positive effect was only observed in the stratum of runners with pronated feet (n=94; HR=0.34; 95% CI 0.13 to 0.84); there was no difference in runners with neutral (n=218; HR=0.78; 95% CI 0.44 to 1.37) or supinated feet (n=60; HR=0.59; 95% CI 0.20 to 1.73). Runners with pronated feet using standard shoes had a higher injury risk compared to those with neutral feet (HR=1.80; 95% CI 1.01 to 3.22). Conclusions The overall injury risk was lower in participants who had received motion control shoes. Based on secondary analysis, those with pronated feet may benefit most from this shoe type. PMID:26746907
Running Habits of Competitive Runners During Pregnancy and Breastfeeding
Tenforde, Adam S.; Toth, Kierann E. S.; Langen, Elizabeth; Fredericson, Michael; Sainani, Kristin L.
2015-01-01
Background: Running is a popular sport that may be performed safely during pregnancy. Few studies have characterized running behavior of competitive female runners during pregnancy and breastfeeding. Hypothesis: Women modify their running behavior during pregnancy and breastfeeding. Study Design: Observational, cross-sectional study. Level of evidence: Level 2. Methods: One hundred ten female long-distance runners who ran competitively prior to pregnancy completed an online survey characterizing training attitudes and behaviors during pregnancy and postpartum. Results: Seventy percent of runners ran some time during their pregnancy (or pregnancies), but only 31% ran during their third trimester. On average, women reduced training during pregnancy, including cutting their intensity to about half of their nonpregnant running effort. Only 3.9% reported sustaining a running injury while pregnant. Fewer than one third (29.9%) selected fetal health as a reason to continue running during pregnancy. Of the women who breastfed, 84.1% reported running during breastfeeding. Most felt that running had no effect on their ability to breastfeed. Women who ran during breastfeeding were less likely to report postpartum depression than those who did not run (6.7% vs 23.5%, P = 0.051), but we did not detect the same association of running during pregnancy (6.5% vs 15.2%, P = 0.16). Conclusion: Women runners reported a reduction in total training while pregnant, and few sustained running injuries during pregnancy. The effect of running on postpartum depression was not clear from our findings. Clinical Relevance: We characterized running behaviors during pregnancy and breastfeeding in competitive runners. Most continue to run during pregnancy but reduce total training effort. Top reasons for running during pregnancy were fitness, health, and maintaining routine; the most common reason for not running was not feeling well. Most competitive runners run during breastfeeding with little perceived impact. PMID:25984264
Effect of age and performance on pacing of marathon runners
Nikolaidis, Pantelis Theodoros; Knechtle, Beat
2017-01-01
Pacing strategies in marathon runners have previously been examined, especially with regard to age and performance level separately. However, less information about the age × performance interaction on pacing in age-group runners exists. The aim of the present study was to examine whether runners with similar race time and at different age differ for pacing. Data (women, n=117,595; men, n=180,487) from the “New York City Marathon” between 2006 and 2016 were analyzed. A between–within subjects analysis of variance showed a large main effect of split on race speed (p<0.001, η2=0.538) with the fastest speed in the 5–10 km split and the slowest in the 35–40 km. A small sex × split interaction on race speed was found (p<0.001, η2=0.035) with men showing larger increase in speed at 5 km and women at 25 km and 40 km (end spurt). An age-group × performance group interaction on Δspeed was shown for both sexes at 5 km, 10 km, 15 km, 20 km, 25 km, 30 km, 35 km, and 40 km (p<0.001, 0.001≤η2≤0.004), where athletes in older age-groups presented a relatively more even pace compared with athletes in younger age-groups, a trend that was more remarkable in the relatively slow performance groups. So far, the present study is the first one to observe an age × performance interaction on pacing; ie, older runners pace differently (smaller changes) than younger runners with similar race time. These findings are of great practical interest for coaches working with marathon runners of different age, but similar race time. PMID:28860876
Do Running Kinematic Characteristics Change over a Typical HIIT for Endurance Runners?
García-Pinillos, Felipe; Soto-Hermoso, Víctor M; Latorre-Román, Pedro Á
2016-10-01
García-Pinillos, F, Soto-Hermoso, VM, and Latorre-Román, PÁ. Do running kinematic characteristics change over a typical HIIT for endurance runners?. J Strength Cond Res 30(10): 2907-2917, 2016-The purpose of this study was to describe kinematic changes that occur during a common high-intensity intermittent training (HIIT) session for endurance runners. Twenty-eight male endurance runners participated in this study. A high-speed camera was used to measure sagittal-plane kinematics at the first and the last run during a HIIT (4 × 3 × 400 m). The dependent variables were spatial-temporal variables, joint angles during support and swing, and foot strike pattern. Physiological variables, rate of perceived exertion, and athletic performance were also recorded. No significant changes (p ≥ 0.05) in kinematic variables were found during the HIIT session. Two cluster analyses were performed, according to the average running pace-faster vs. slower, and according to exhaustion level reached-exhausted group vs. nonexhausted group (NEG). At first run, no significant differences were found between groups. As for the changes induced by the running protocol, significant differences (p ≤ 0.05) were found between faster and slower athletes at toe-off in θhip and θknee, whereas some changes were found in NEG in θhip during toe-off (+4.3°) and θknee at toe-off (-5.2°) during swing. The results show that a common HIIT session for endurance runners did not consistently or substantially perturb the running kinematics of trained male runners. Additionally, although some differences between groups have been found, neither athletic performance nor exhaustion level reached seems to be determinant in the kinematic response during a HIIT, at least for this group of moderately trained endurance runners.
Buist, Ida; Bredeweg, Steef W; Lemmink, Koen A P M; van Mechelen, Willem; Diercks, Ron L
2010-02-01
The popularity of running is still growing. As participation increases, running-related injuries also increase. Until now, little is known about the predictors for injuries in novice runners. Predictors for running-related injuries (RRIs) will differ between male and female novice runners. Cohort study; Level of evidence, 2. Participants were 532 novice runners (226 men, 306 women) preparing for a recreational 4-mile (6.7-km) running event. After completing a baseline questionnaire and undergoing an orthopaedic examination, they were followed during the training period of 13 weeks. An RRI was defined as any self-reported running-related musculoskeletal pain of the lower extremity or back causing a restriction of running for at least 1 week. Twenty-one percent of the novice runners had at least one RRI during follow-up. The multivariate adjusted Cox regression model for male participants showed that body mass index (BMI) (hazard ratio [HR], 1.15; 95% confidence interval [CI], 1.05-1.26), previous injury in the past year (HR, 2.7; 95% CI, 1.36-5.55), and previous participation in sports without axial load (HR, 2.05; 95% CI, 1.03-4.11) were associated with RRI. In female participants, only navicular drop (HR, 0.85; 95% CI, 0.75-0.97) remained a significant predictor for RRI in the multivariate Cox regression modeling. Type A behavior and range of motion (ROM) of the hip and ankle did not affect risk. Male and female novice runners have different risk profiles. Higher BMI, previous injury, and previous sports participation without axial loading are important predictors for RRI in male participants. Further research is needed to detect more predictors for female novice runners.
Primitive running: a survey analysis of runners' interest, participation, and implementation.
Rothschild, Carey E
2012-08-01
Running is a sport that has continued to see growth in numbers over the years. Recently, there has been a movement promoting running barefoot and in light, "minimalist" shoes. Advocates of barefoot running believe that a more primitive style of running may result in fewer running-related injuries and even possibly improve performance. To identify the current interest level and participation in barefoot or minimalist shod running, an electronic survey was developed and dispersed to 6,082 runners. The survey instrument examined demographics, motivating factors, used resources, perceived barriers, and expectations in runners who add barefoot or in minimalist shod running to their training. Seven hundred eighty-five (13%) runners completed the survey. Six hundred and thirty (75.7%) indicated they were at least somewhat interested in running barefoot or in minimalist shoes. One hundred seventy-two (21.9%) runners had previously tried barefoot running, whereas 239 (30.4%) had previously tried minimalist shoes. The primary motivating factor for those running barefoot or in minimalist shoes (n = 283) was to prevent future injury (n = 97, 34.3%). Advice from friends (n = 68, 24.5%) or books (n = 68, 24.5%) was the most commonly used resource in transitioning to barefoot or minimalist shod running. Fear of possible injury (n = 424, 54%) was the most prevalent perceived barrier in transitioning to barefoot or minimalist shod running. An overwhelming 671 (85.5%) indicated that they were at least somewhat likely to continue with or to add barefoot or minimalist shod running if provided sufficient instruction. Runners who are men, of younger age, and who consider themselves elite runners are somewhat more likely to be interested in barefoot or minimalist shod running.
Effects of training in minimalist shoes on the intrinsic and extrinsic foot muscle volume.
Chen, Tony Lin-Wei; Sze, Louis K Y; Davis, Irene S; Cheung, Roy T H
2016-07-01
Minimalist shoes have gained popularity recently because it is speculated to strengthen the foot muscles and foot arches, which may help to resist injuries. However, previous studies provided limited evidence supporting the link between changes in muscle size and footwear transition. Therefore, this study sought to examine the effects of minimalist shoes on the intrinsic and extrinsic foot muscle volume in habitual shod runners. The relationship between participants' compliance with the minimalist shoes and changes in muscle õvolume was also evaluated. Twenty habitual shod runners underwent a 6-month self-monitoring training program designed for minimalist shoe transition. Another 18 characteristics-matched shod runners were also introduced with the same program but they maintained running practice with standard shoes. Runners were monitored using an online surveillance platform during the program. We measured overall intrinsic and extrinsic foot muscle volume before and after the program using MRI scans. Runners in the experimental group exhibited significantly larger leg (P=0.01, Cohen's d=0.62) and foot (P<0.01, Cohen's d=0.54) muscle after transition. Foot muscle growth was mainly contributed by the forefoot (P<0.01, Cohen's d=0.64) but not the rearfoot muscle (P=0.10, Cohen's d=0.30). Leg and foot muscle volume of runners in the control group remained similar after the program (P=0.33-0.95). A significant positive correlation was found between participants' compliance with the minimalist shoes and changes in leg muscle volume (r=0.51; P=0.02). Habitual shod runners who transitioned to minimalist shoes demonstrated significant increase in leg and foot muscle volume. Additionally, the increase in leg muscle volume was significantly correlated associated with the compliance of minimalist shoe use. Copyright © 2016 Elsevier Ltd. All rights reserved.
Biomechanical Factors in the Etiology of Tibial Stress Fractures
2002-08-01
structures will control the kinematics of the runner. A "stiff runner will spend less time in contact with the ground (Farley and Gonzalez, 1996 ) and will...a SF are in agreement with Farley and Gonzalez ( 1996 ) and suggest that lower extremity stiffness and knee kinematics are highly correlated and may...stressfracture in male runners. Med Sei Sports Exercise 31(8), 1088-1093. Farley CT, Gonzalez O. ( 1996 ) Leg stiffness and stride frequency in human running. J
Ankle plantarflexion strength in rearfoot and forefoot runners: a novel clusteranalytic approach.
Liebl, Dominik; Willwacher, Steffen; Hamill, Joseph; Brüggemann, Gert-Peter
2014-06-01
The purpose of the present study was to test for differences in ankle plantarflexion strengths of habitually rearfoot and forefoot runners. In order to approach this issue, we revisit the problem of classifying different footfall patterns in human runners. A dataset of 119 subjects running shod and barefoot (speed 3.5m/s) was analyzed. The footfall patterns were clustered by a novel statistical approach, which is motivated by advances in the statistical literature on functional data analysis. We explain the novel statistical approach in detail and compare it to the classically used strike index of Cavanagh and Lafortune (1980). The two groups found by the new cluster approach are well interpretable as a forefoot and a rearfoot footfall groups. The subsequent comparison study of the clustered subjects reveals that runners with a forefoot footfall pattern are capable of producing significantly higher joint moments in a maximum voluntary contraction (MVC) of their ankle plantarflexor muscles tendon units; difference in means: 0.28Nm/kg. This effect remains significant after controlling for an additional gender effect and for differences in training levels. Our analysis confirms the hypothesis that forefoot runners have a higher mean MVC plantarflexion strength than rearfoot runners. Furthermore, we demonstrate that our proposed stochastic cluster analysis provides a robust and useful framework for clustering foot strikes. Copyright © 2014 Elsevier B.V. All rights reserved.
The collision forces and lower-extremity inter-joint coordination during running.
Wang, Li-I; Gu, Chin-Yi; Wang, I-Lin; Siao, Sheng-Wun; Chen, Szu-Ting
2018-06-01
The purpose of this study was to compare the lower extremity inter-joint coordination of different collision forces runners during running braking phase. A dynamical system approach was used to analyse the inter-joint coordination parameters. Data were collected with six infra-red cameras and two force plates. According to the impact peak of the vertical ground reaction force, twenty habitually rearfoot-strike runners were categorised into three groups: high collision forces runners (HF group, n = 8), medium collision forces runners (MF group, n = 5), and low collision forces runners (LF group, n = 7). There were no significant differences among the three groups in the ankle and knee joint angle upon landing and in the running velocity (p > 0.05). The HF group produced significantly smaller deviation phase (DP) of the hip flexion/extension-knee flexion/extension during the braking phase compared with the MF and LF groups (p < 0.05). The DP of the hip flexion/extension-knee flexion/extension during the braking phase correlated negatively with the collision force (p < 0.05). The disparities regarding the flexibility of lower extremity inter-joint coordination were found in high collision forces runners. The efforts of the inter-joint coordination and the risk of running injuries need to be clarified further.
Ikedo, Aoi; Ishibashi, Aya; Matsumiya, Saori; Kaizaki, Aya; Ebi, Kumiko; Fujita, Satoshi
2016-01-01
We aimed to compare site-specific bone mineral densities (BMDs) between adolescent endurance runners and sprinters and examine the relationship of fat-free mass (FFM) and nutrient intake on BMD. In this cross-sectional study, 37 adolescent female endurance runners and sprinters (16.1 ± 0.8 years) were recruited. BMD and FFM were assessed by dual-energy X-ray absorptiometry. Nutrient intake and menstrual state were evaluated by questionnaires. After adjusting for covariates, spine and total bone less head (TBLH) BMDs were significantly higher in sprinters than endurance runners (TBLH, 1.02 ± 0.05 vs. 0.98 ± 0.06 g/cm2; spine, 0.99 ± 0.06 vs. 0.94 ± 0.06 g/cm2; p < 0.05). There was no significant difference between groups in other sites. The rate of menstrual abnormality was higher in endurance runners compared with sprinters (56.3% vs. 23.8%; p < 0.05). FFM was a significant covariate for BMD on all sites except the spine (p < 0.05). Dietary intake of vitamin D was identified as a significant covariate only for pelvic BMD (p < 0.05). The BMDs of different sites among endurance runners and sprinters were strongly related to FFM. However, the association of FFM with spine BMD cannot be explained by FFM alone. Other factors, including nutrition and/or mechanical loading, may affect the spine BMD. PMID:27916891
Transient myocardial tissue and function changes during a marathon in less fit marathon runners.
Gaudreault, Valerie; Tizon-Marcos, Helena; Poirier, Paul; Pibarot, Philippe; Gilbert, Philippe; Amyot, Marc; Rodés-Cabau, Josep; Després, Jean-Pierre; Bertrand, Olivier; Larose, Eric
2013-10-01
Although regular physical activity improves health, strenuous exercise might transiently increase cardiac risk. Training and fitness might provide protection. We prospectively studied 20 recreational marathon runners without known cardiovascular disease or symptoms: at peak training before, immediately after, and 3 months after a 42.2-km marathon. Changes in global/segmental myocardial function, edema, resting perfusion, and fibrosis were measured. At peak training, runners exercised 8.1 ± 2.3 hours and 62 ± 18 km per week with mean maximal oxygen consumption (VO2max) of 53.2 ± 8.3 mL/kg/min. In response to the marathon, global left ventricular and right ventricular ejection fraction decreased in half of the runners; these runners had poorer peak training distance, training time, and fitness level. Change in global left ventricular ejection fraction was associated with VO2max. Overall, 36% of segments developed edema, 53% decreased function, and 59% decreased perfusion. Significant agreement was observed between segment decreasing function, decreasing perfusion, and developing edema. Myocardial changes were reversible at 3 months. Completing a marathon leads to localized myocardial edema, diminished perfusion, and decreased function occurring more extensively in less trained and fit runners. Although reversible, these changes might contribute to the transient increase in cardiac risk reported during sustained vigorous exercise. Copyright © 2013 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
EMG and tibial shock upon the first attempt at barefoot running.
Olin, Evan D; Gutierrez, Gregory M
2013-04-01
As a potential means to decrease their risk of injury, many runners are transitioning into barefoot running. Habitually shod runners tend to heel-strike (SHS), landing on their heel first, while barefoot runners tend to mid-foot or toe-strike (BTS), landing flat-footed or on the ball of their foot before bringing down the rest of the foot including the heel. This study compared muscle activity, tibial shock, and knee flexion angle in subjects between shod and barefoot conditions. Eighteen habitually SHS recreational runners ran for 3 separate 7-minute trials, including SHS, barefoot heel-strike (BHS), and BTS conditions. EMG, tibial shock, and knee flexion angle were monitored using bipolar surface electrodes, an accelerometer, and an electrogoniometer, respectively. A one-way MANOVA for repeated measures was conducted and several significant changes were noted between SHS and BTS, including significant increases in average EMG of the medial gastrocnemius (p=.05), average and peak tibial shock (p<.01), and the minimum knee flexion angle (p<.01). Based on our data, the initial change in mechanics may have detrimental effects on the runner. While it has been argued that BTS running may ultimately be less injurious, these data indicate that habitually SHS runners who choose to transition into a BTS technique must undertake the process cautiously. Copyright © 2012 Elsevier B.V. All rights reserved.
Swirling Flow Computation at the Trailing Edge of Radial-Axial Hydraulic Turbines
NASA Astrophysics Data System (ADS)
Susan-Resiga, Romeo; Muntean, Sebastian; Popescu, Constantin
2016-11-01
Modern hydraulic turbines require optimized runners within a range of operating points with respect to minimum weighted average draft tube losses and/or flow instabilities. Tractable optimization methodologies must include realistic estimations of the swirling flow exiting the runner and further ingested by the draft tube, prior to runner design. The paper presents a new mathematical model and the associated numerical algorithm for computing the swirling flow at the trailing edge of Francis turbine runner, operated at arbitrary discharge. The general turbomachinery throughflow theory is particularized for an arbitrary hub-to-shroud line in the meridian half-plane and the resulting boundary value problem is solved with the finite element method. The results obtained with the present model are validated against full 3D runner flow computations within a range of discharge value. The mathematical model incorporates the full information for the relative flow direction, as well as the curvatures of the hub-to-shroud line and meridian streamlines, respectively. It is shown that the flow direction can be frozen within a range of operating points in the neighborhood of the best efficiency regime.
NASA Astrophysics Data System (ADS)
Zouhar, J.; Obrovsky, J.; Feilhauer, M.; Skotak, A.
2016-11-01
The refurbishment of the Lipno I TG2 Francis turbine, situated on River Vltava, with maximum net head of 165 m and required operational range from 0 to 67MW of turbine power was performed in 2014. The new hydraulic design of the spiral case, distributor and runner was developed for this project. After about 1000 hours of operation the site inspection was performed and the cracks were found on 8 runner blades of 17 blades altogether. The all cracks were found near runner hub beginning from the trailing edge. The dimensions of the cracks were different with maximum length of 123 mm and minimum length of 3 mm. The runner was repaired and the intensive investigation was started to define the main cause of the cracks creation and to determine the measures for their elimination. This paper presents the program of this investigation which consists of static and dynamic blade strain measurement, CFD and FEM analysis, discusses the crack causes and overview the solution how to return the turbine successfully to operation.
Chukwumah, Yvonne; Walker, Lloyd; Vogler, Bernhard; Verghese, Martha
2012-05-01
Peanuts are classified into four market-types (Runners, Spanish, Virginia and Valencia). Studies on their phytochemical composition have focused mainly on market-types other than Valencia. The objectives of this study are to evaluate the phytochemical composition of cultivars of Valencia and Runner market-types. Extracts of 25 peanut cultivars of Runner and Valencia market-types were analysed using HPLC-DAD-MS analysis. Results showed major differences in UV profile of the market-types. A major peak with m/z 317 identified as isorhamnetin was present only in Valencia cultivars while its glycoside (isorhamnetin-3-O-rutinoside) having m/z 625 was identified in both market-types. Genistein, daidzein, rutin, quercetin and trans-resveratrol were also identified and quantified. Genistein and daidzein concentrations (0.03mg/100g) were similar in both market-types. trans-Resveratrol and rutin were significantly (p<0.05) higher in Runner cultivars while quercetin was 10-fold higher (0.60±0.04mg/100g) in Valencia cultivars making them a better source of this phytochemical. Copyright © 2011 Elsevier Ltd. All rights reserved.
Optimization of Gate, Runner and Sprue in Two-Plate Family Plastic Injection Mould
NASA Astrophysics Data System (ADS)
Amran, M. A.; Hadzley, M.; Amri, S.; Izamshah, R.; Hassan, A.; Samsi, S.; Shahir, K.
2010-03-01
This paper describes the optimization size of gate, runner and sprue in two-plate family plastic injection mould. An Electronic Cash Register (ECR) plastic product was used in this study, which there are three components in electronic cast register plastic product consist of top casing, bottom casing and paper holder. The objectives of this paper are to find out the optimum size of gate, runner and sprue, to locate the optimum layout of cavities and to recognize the defect problems due to the wrong size of gate, runner and sprue. Three types of software were used in this study, which Unigraphics software as CAD tool was used to design 3D modeling, Rhinoceros software as post processing tool was used to design gate, runner and sprue and Moldex software as simulation tool was used to analyze the plastic flow. As result, some modifications were made on size of feeding system and location of cavity to eliminate the short- shot, over filling and welding line problems in two-plate family plastic injection mould.
Injuries observed in minimalist runners.
Salzler, Matthew J; Bluman, Eric M; Noonan, Samantha; Chiodo, Christopher P; de Asla, Richard J
2012-04-01
Minimalist runners have been shown to have a different gait pattern with lower impact forces than habitually shod runners. Running in minimalist footwear has been promoted as a means of reducing or eliminating running injuries by returning to a more natural gait. Ten experienced runners, age 21 to 57 (mean, 43) years, were identified with injuries within 1 year of transition from traditional to minimalist running footwear. Patients were interviewed to determine their running history, injury history, transition to minimalist footwear, and their new injury including its treatment and recovery. Ten patients who ran with traditional footwear ran an average of 25.9 (range, 6 to 45) miles/week for an average of 18.9 (range, 1 to 40) years presented with injuries 2.8 (range 1 to 10) months after switching to minimalist footwear. Their injuries included eight metatarsal stress fractures, a calcaneal stress fracture, and a plantar fascia rupture. All patients had a successful recovery and returned to their previous level of running. Injuries including stress fractures and plantar fascia rupture have been observed in minimalist runners.
Carling; Williams; Bowtell
1998-12-01
Anguilliform swimming has been investigated by using a computational model combining the dynamics of both the creature's movement and the two-dimensional fluid flow of the surrounding water. The model creature is self-propelled; it follows a path determined by the forces acting upon it, as generated by its prescribed changing shape. The numerical solution has been obtained by applying coordinate transformations and then using finite difference methods. Results are presented showing the flow around the creature as it accelerates from rest in an enclosed tank. The kinematics and dynamics associated with the creature's centre of mass are also shown. For a particular set of body shape parameters, the final mean swimming speed is found to be 0.77 times the speed of the backward-travelling wave. The corresponding movement amplitude envelope is shown. The magnitude of oscillation in the net forward force has been shown to be approximately twice that in the lateral force. The importance of allowing for acceleration and deceleration of the creature's body (rather than imposing a constant swimming speed) has been demonstrated. The calculations of rotational movement of the body and the associated moment of forces about the centre of mass have also been included in the model. The important role of viscous forces along and around the creature's body and in the growth and dissolution of the vortex structures has been illustrated.
NASA Technical Reports Server (NTRS)
Deere, Karen A.; Viken, Sally A.; Carter, Melissa B.; Viken, Jeffrey K.; Wiese, Michael R.; Farr, Norma L.
2017-01-01
A computational study of a distributed electric propulsion wing with a 40deg flap deflection has been completed using FUN3D. Two lift-augmentation power conditions were compared with the power-off configuration on the high-lift wing (40deg flap) at a 73 mph freestream flow and for a range of angles of attack from -5 degrees to 14 degrees. The computational study also included investigating the benefit of corotating versus counter-rotating propeller spin direction to powered-lift performance. The results indicate a large benefit in lift coefficient, over the entire range of angle of attack studied, by using corotating propellers that all spin counter to the wingtip vortex. For the landing condition, 73 mph, the unpowered 40deg flap configuration achieved a maximum lift coefficient of 2.3. With high-lift blowing the maximum lift coefficient increased to 5.61. Therefore, the lift augmentation is a factor of 2.4. Taking advantage of the fullspan lift augmentation at similar performance means that a wing powered with the distributed electric propulsion system requires only 42 percent of the wing area of the unpowered wing. This technology will allow wings to be 'cruise optimized', meaning that they will be able to fly closer to maximum lift over drag conditions at the design cruise speed of the aircraft.
Echocardiographic left ventricular masses in distance runners and weight lifters
NASA Technical Reports Server (NTRS)
Longhurst, J. C.; Gonyea, W. J.; Mitchell, J. H.; Kelly, A. R.
1980-01-01
The relationships of different forms of exercise training to left ventricular mass and body mass are investigated by echocardiographic studies of weight lifters, long-distance runners, and comparatively sized untrained control subjects. Left ventricular mass determinations by the Penn convention reveal increased absolute left ventricular masses in long-distance runners and competitive weight lifters with respect to controls matched for age, body weight, and body surface area, and a significant correlation between ventricular mass and lean body mass. When normalized to lean body mass, the ventricular masses of distance runners are found to be significantly higher than those of the other groups, suggesting that dynamic training elevates left ventricular mass compared to static training and no training, while static training increases ventricular mass only to the extent that lean body mass is increased.
The Feasibility and Usability of RunningCoach: A Remote Coaching System for Long-Distance Runners †
Bajcsy, Ruzena
2018-01-01
Studies have shown that about half of the injuries sustained during long-distance running involve the knee. Cadence (steps per minute) has been identified as a factor that is strongly associated with these running-related injuries, making it a worthwhile candidate for further study. As such, it is critical for long-distance runners to minimize their risk of injury by running at an appropriate running cadence. In this paper, we present the results of a study on the feasibility and usability of RunningCoach, a mobile health (mHealth) system that remotely monitors running cadence levels of runners in a continuous fashion, among other variables, and provides immediate feedback to runners in an effort to help them optimize their running cadence. PMID:29320436
Ice Friction in the Sport of Bobsleigh
NASA Astrophysics Data System (ADS)
Poirier, Louis
The primary objective of this work is to examine the effect of the bobsleigh runner profile on ice / runner friction. The work is centered on a computational model (F.A.S.T. 3.2b) which calculates the coefficient of friction between a steel blade and ice. The first step was to analyze runners used in the sport of bobsleigh. This analysis was performed using a handheld rocker gauge, a device used in speed skating. The size of the device was optimized for hockey, short and long track speed skating, and bobsleigh. A number of runners were measured using the gauge and it was found that the portion of the runner contacting the ice generally has a rocker value of (20--50) m. Next, the hardness of athletic ice surfaces was analyzed. The ice hardness was determined by dropping steel balls varying in mass from (8--540) g onto the ice surface, from a height of (0.3--1.2) m, and measuring the diameter of the indentation craters. The ice hardness was found to be P¯(T) = ((--0.6 +/- 0.4) T + 14.7 +/- 2.1) MPa and the elastic recovery of the ice surface was found to be negligible. The F.A.S.T. model was adapted from a speed skate model to calculate the coefficient of friction between a bobsleigh runner and a flat ice surface. The model predicts that maximum velocities are obtained for temperatures between --10 and --20°C, in agreement with observations on the Calgary bobsleigh track. The model for flat ice suggests that the flattest runners produce the lowest coefficient of friction and that the rocker affects friction more than the cross-sectional radius. The coefficient of friction between runners and ice and the drag performance of 2-men bobsleighs were determined from radar speed measurements taken at the Calgary Olympic Oval and at Canada Olympic Park: at the Ice House and on the bobsleigh track during a World Cup competition. The mean coefficient of friction was found to be mu = (5.3 +/- 2.0) x 10--3 and the mean drag performance was CdA = (0.18 +/- 0.02) m2.
Olenski, Andrew R; Abola, Matthew V
2015-01-01
Objectives To determine whether being elected to head of government is associated with accelerated mortality by studying survival differences between people elected to office and unelected runner-up candidates who never served. Design Observational study. Setting Historical survival data on elected and runner-up candidates in parliamentary or presidential elections in Australia, Austria, Canada, Denmark, Finland, France, Germany, Greece, Ireland, Italy, New Zealand, Norway, Poland, Spain, Sweden, United Kingdom, and United States, from 1722 to 2015. Participants Elected and runner-up political candidates. Main outcome measure Observed number of years alive after each candidate’s last election, relative to what would be expected for an average person of the same age and sex as the candidate during the year of the election, based on historical French and British life tables. Observed post-election life years were compared between elected candidates and runners-up, adjusting for life expectancy at time of election. A Cox proportional hazards model (adjusted for candidate’s life expectancy at the time of election) considered years until death (or years until end of study period for those not yet deceased by 9 September 2015) for elected candidates versus runners-up. Results The sample included 540 candidates: 279 winners and 261 runners-up who never served. A total of 380 candidates were deceased by 9 September 2015. Candidates who served as a head of government lived 4.4 (95% confidence interval 2.1 to 6.6) fewer years after their last election than did candidates who never served (17.8 v 13.4 years after last election; adjusted difference 2.7 (0.6 to 4.8) years). In Cox proportional hazards analysis, which considered all candidates (alive or deceased), the mortality hazard for elected candidates relative to runners-up was 1.23 (1.00 to 1.52). Conclusions Election to head of government is associated with a substantial increase in mortality risk compared with candidates in national elections who never served. PMID:26666894
Olenski, Andrew R; Abola, Matthew V; Jena, Anupam B
2015-12-14
To determine whether being elected to head of government is associated with accelerated mortality by studying survival differences between people elected to office and unelected runner-up candidates who never served. Observational study. Historical survival data on elected and runner-up candidates in parliamentary or presidential elections in Australia, Austria, Canada, Denmark, Finland, France, Germany, Greece, Ireland, Italy, New Zealand, Norway, Poland, Spain, Sweden, United Kingdom, and United States, from 1722 to 2015. Elected and runner-up political candidates. Observed number of years alive after each candidate's last election, relative to what would be expected for an average person of the same age and sex as the candidate during the year of the election, based on historical French and British life tables. Observed post-election life years were compared between elected candidates and runners-up, adjusting for life expectancy at time of election. A Cox proportional hazards model (adjusted for candidate's life expectancy at the time of election) considered years until death (or years until end of study period for those not yet deceased by 9 September 2015) for elected candidates versus runners-up. The sample included 540 candidates: 279 winners and 261 runners-up who never served. A total of 380 candidates were deceased by 9 September 2015. Candidates who served as a head of government lived 4.4 (95% confidence interval 2.1 to 6.6) fewer years after their last election than did candidates who never served (17.8 v 13.4 years after last election; adjusted difference 2.7 (0.6 to 4.8) years). In Cox proportional hazards analysis, which considered all candidates (alive or deceased), the mortality hazard for elected candidates relative to runners-up was 1.23 (1.00 to 1.52). Election to head of government is associated with a substantial increase in mortality risk compared with candidates in national elections who never served. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
2010-08-25
Under the unflinching summer sun, workers at NASA Deep Space Network complex in Goldstone, Calif., use a crane to lift a runner segment that is part of major surgery on a giant, 70-meter-wide antenna.
RUNNER BOX MAINTENANCE. FRANK FEHER USES A COMPRESSED AIRPOWERED CHISEL ...
RUNNER BOX MAINTENANCE. FRANK FEHER USES A COMPRESSED AIR-POWERED CHISEL TO CHIP OUT CONGEALED METAL IN PREPARATION FOR ANOTHER HEAT. - American Brass Foundry, 70 Sayre Street, Buffalo, Erie County, NY
Hip Biomechanics Are Altered in Male Runners with Achilles Tendinopathy.
Creaby, Mark W; Honeywill, Conor; Franettovich Smith, Melinda M; Schache, Anthony G; Crossley, Kay M
2017-03-01
Achilles tendinopathy (AT) is a prevalent injury in running sports. Understanding the biomechanical factors associated with AT will assist in its management and prevention. The purpose of this study was to compare hip and ankle kinematics and kinetics in runners with and without AT. Fourteen male runners with AT and 11 healthy male runners (CTRL) ran over ground while lower-limb joint motion and ground reaction force data were synchronously captured. Hip and ankle joint angles, moments, and impulses in all three planes (sagittal, transverse, and frontal) were extracted for analysis. Independent t-tests were used to compare the differences between the AT and the CTRL groups for the biomechanical variables of interest. After Bonferroni adjustment, an alpha level of 0.0026 was set for all analyses. The AT group exhibited an increased peak hip external rotation moment (P = 0.001), hip external rotation impulse (P < 0.001), and hip adduction impulse (P < 0.001) compared with the CTRL group. No significant differences in ankle biomechanics were observed. This study presents preliminary evidence indicating that male runners with AT display altered hip biomechanics with respect to their healthy counterparts. Because of the retrospective design of the study, it is unknown whether these alterations are a predisposing factor for the disorder, a result of the condition, or a combination of both. The results of this study suggest that optimizing hip joint function should be considered in the rehabilitation of runners with AT.
Edwards, A M; Challis, N V; Chapman, J H; Claxton, D B; Fysh, M L
1999-01-01
The aim of the study was to examine whether a measure of oxygen uptake (VO2) kinetics could differentiate between 12 elite male endurance (3000-10,000 m) runners and 12 elite male sprint (100-400 m) runners using a pseudo random binary sequence (PRBS) exercise protocol. All exercise tests were performed on an electrically braked cycle ergometer at a constant pedal frequency of 1 Hz. The PRBS exercise intensities alternated between 25 W and 85 W for three consecutive PRBS cycles of 300 s. VO2 was measured breath-by-breath and results were analysed by Fourier techniques in the frequency domain. Blood lactate concentrations taken pre and post testing were below 2 mM. Significantly greater amplitude components were observed in the endurance runners than sprinters at frequencies 6.7 mHz (6.71 +/- 1.09 and 5.47 +/- 0.95 ml x min(-1) x W(-1), respectively) P<0.05 and 10 mHz (4.97 +/- 0.98 and 3.56 +/- 0.69 ml x min(-1) x W(-1) respectively) P<0.01. Phase shift components were significantly shorter in the endurance runners compared to the sprinters at frequency 3.3 mHz (-35.45 +/- 4.31 and -41.26 +/- 5.82 degrees respectively) P<0.05. The results of this study show that VO2 kinetics are differentially faster in elite endurance runners than in elite sprinters. This supports the development of the PRBS technique as a test of sports performance.
Tam, Nicholas; Astephen Wilson, Janie L; Coetzee, Devon R; van Pletsen, Leanri; Tucker, Ross
2016-05-01
The purpose of this study was to examine the effect of barefoot running on initial loading rate (LR), lower extremity joint kinematics and kinetics, and neuromuscular control in habitually shod runners with an emphasis on the individual response to this unfamiliar condition. Kinematics and ground reaction force data were collected from 51 habitually shod runners during overground running in a barefoot and shod condition. Joint kinetics and stiffness were calculated with inverse dynamics. Inter-individual initial LR variability was explored by separating individuals by a barefoot/shod ratio to determine acute responders/non-responders. Mean initial LR was 54.1% greater in the barefoot when compared to the shod condition. Differences between acute responders/non-responders were found at peak and initial contact sagittal ankle angle and at initial ground contact. Correlations were found between barefoot sagittal ankle angle at initial ground contact and barefoot initial LR. A large variability in biomechanical responses to an acute exposure to barefoot running was found. A large intra-individual variability was found in initial LR but not ankle plantar-dorsiflexion between footwear conditions. A majority of habitually shod runners do not exhibit previously reported benefits in terms of reduced initial LRs when barefoot. Lastly, runners who increased LR when barefoot reduced LRs when wearing shoes to levels similar seen in habitually barefoot runners who do adopt a forefoot-landing pattern, despite increased dorsiflexion. Copyright © 2016 Elsevier B.V. All rights reserved.
Stahl, Robert; Luke, Anthony; Ma, C Benjamin; Krug, Roland; Steinbach, Lynne; Majumdar, Sharmila; Link, Thomas M
2008-07-01
To determine the prevalence of pathologic findings in asymptomatic knees of marathon runners before and after a competition in comparison with physically active subjects. To compare the diagnostic performance of cartilage-dedicated magnetic resonance imaging (MRI) sequences at 3.0 T. Ten marathon runners underwent 3.0 T MRI 2-3 days before and after competition. Twelve physically active asymptomatic subjects not performing long-distance running were examined as controls. Pathologic condition was assessed with the whole-organ magnetic resonance imaging score (WORMS). Cartilage abnormalities and bone marrow edema pattern (BMEP) were quantified. Visualization of cartilage pathology was assessed with intermediate-weighted fast spin-echo (IM-w FSE), fast imaging employing steady-state acquisition (FIESTA) and T1-weighted three-dimensional (3D) high-spatial-resolution volumetric fat-suppressed spoiled gradient-echo (SPGR) MRI sequences. Eight of ten marathon runners and 7/12 controls showed knee abnormality. Slightly more and larger cartilage abnormalities, and BMEP, in marathon runners yielded higher but not significantly different WORMS (P > 0.05) than in controls. Running a single marathon did not alter MR findings substantially. Cartilage abnormalities were best visualized with IM-w FSE images (P < 0.05). A high prevalence of knee abnormalities was found in marathon runners and also in active subjects participating in other recreational sports. IM-w FSE sequences delineated more cartilage MR imaging abnormalities than did FIESTA and SPGR sequences.
WEEKLY RUNNING VOLUME AND RISK OF RUNNING‐RELATED INJURIES AMONG MARATHON RUNNERS
Nielsen, Rasmus Oestergaard; Juul, Martin Serup; Rasmussen, Sten
2013-01-01
Purpose/Background: The purpose of this study was to investigate if the risk of injury declines with increasing weekly running volume before a marathon race. Methods: The study was a retrospective cohort study on marathon finishers. Following a marathon, participants completed a web‐based questionnaire. The outcome of interest was a self‐reported running‐related injury. The injury had to be severe enough to cause a reduction in distance, speed, duration or frequency of running for at least 14 days. Primary exposure was self‐reported average weekly volume of running before the marathon categorized into below 30 km/week, 30 to 60 km/week, and above 60 km/week. Results: A total of 68 of the 662 respondents sustained an injury. When adjusting for previous injury and previous marathons, the relative risk (RR) of suffering an injury rose by 2.02 [95% CI: 1.26; 3.24], p < 0.01, among runners with an average weekly training volume below 30 km/week compared with runners with an average weekly training volume of 30‐60 km/week. No significant differences were found between runners exceeding 60 km/week and runners running 30‐60 km/week (RR=1.13 [0.5;2.8], p=0.80). Conclusions: Runners may be advised to run a minimum of 30 km/week before a marathon to reduce their risk of running‐related injury. Level of Evidence: 2b PMID:23593549
Bredeweg, Steef W; Zijlstra, Sjouke; Bessem, Bram; Buist, Ida
2012-09-01
There is no consensus on the aetiology and prevention of running-related injuries in runners. Preconditioning studies among different athlete populations show positive effects on the incidence of sports injuries. A 4-week preconditioning programme in novice runners will reduce the incidence of running-related injuries. Randomised controlled clinical trial; level of evidence, 1. Novice runners (N=432) prepared for a four-mile recreational running event. Participants were allocated to the 4-week preconditioning (PRECON) group (N=211) or the control group (N=221). The PRECON group started a 4-week training programme, prior to the running programme, with walking and hopping exercises. After the 4-week period both groups started a 9-week running programme. In both groups information was registered on running exposure and running-related injuries (RRIs) using an internet-based running log. Primary outcome measure was RRIs per 100 runners. An RRI was defined as any musculoskeletal complaint of the lower extremity or lower back causing restriction of running for at least a week. The incidence of RRIs was 15.2% in the PRECON group and 16.8% in the control group. The difference in RRIs between the groups was not significant (χ(2)=0.161, df=1, p=0.69). This prospective study demonstrated that a 4-week PRECON programme with walking and hopping exercises had no influence on the incidence of RRIs in novice runners.
Matias, Alessandra B; Taddei, Ulisses T; Duarte, Marcos; Sacco, Isabel C N
2016-04-14
Overall performance, particularly in a very popular sports activity such as running, is typically influenced by the status of the musculoskeletal system and the level of training and conditioning of the biological structures. Any change in the musculoskeletal system's biomechanics, especially in the feet and ankles, will strongly influence the biomechanics of runners, possibly predisposing them to injuries. A thorough understanding of the effects of a therapeutic approach focused on feet biomechanics, on strength and functionality of lower limb muscles will contribute to the adoption of more effective therapeutic and preventive strategies for runners. A randomized, prospective controlled and parallel trial with blind assessment is designed to study the effects of a "ground-up" therapeutic approach focused on the foot-ankle complex as it relates to the incidence of running-related injuries in the lower limbs. One hundred and eleven (111) healthy long-distance runners will be randomly assigned to either a control (CG) or intervention (IG) group. IG runners will participate in a therapeutic exercise protocol for the foot-ankle for 8 weeks, with 1 directly supervised session and 3 remotely supervised sessions per week. After the 8-week period, IG runners will keep exercising for the remaining 10 months of the study, supervised only by web-enabled software three times a week. At baseline, 2 months, 4 months and 12 months, all runners will be assessed for running-related injuries (primary outcome), time for the occurrence of the first injury, foot health and functionality, muscle trophism, intrinsic foot muscle strength, dynamic foot arch strain and lower-limb biomechanics during walking and running (secondary outcomes). This is the first randomized clinical trial protocol to assess the effect of an exercise protocol that was designed specifically for the foot-and-ankle complex on running-related injuries to the lower limbs of long-distance runners. We intend to show that the proposed protocol is an innovative and effective approach to decreasing the incidence of injuries. We also expect a lengthening in the time of occurrence of the first injury, an improvement in foot function, an increase in foot muscle mass and strength and beneficial biomechanical changes while running and walking after a year of exercising. Clinicaltrials.gov Identifier NCT02306148 (November 28, 2014) under the name "Effects of Foot Strengthening on the Prevalence of Injuries in Long Distance Runners". Committee of Ethics in Research of the School of Medicine of the University of Sao Paulo (18/03/2015, Protocol # 031/15).
NASA Astrophysics Data System (ADS)
Alligné, S.; Maruzewski, P.; Dinh, T.; Wang, B.; Fedorov, A.; Iosfin, J.; Avellan, F.
2010-08-01
The growing development of renewable energies combined with the process of privatization, lead to a change of economical energy market strategies. Instantaneous pricings of electricity as a function of demand or predictions, induces profitable peak productions which are mainly covered by hydroelectric power plants. Therefore, operators harness more hydroelectric facilities at full load operating conditions. However, the Francis Turbine features an axi-symmetric rope leaving the runner which may act under certain conditions as an internal energy source leading to instability. Undesired power and pressure fluctuations are induced which may limit the maximum available power output. BC Hydro experiences such constraints in a hydroelectric power plant consisting of four 435 MW Francis Turbine generating units, which is located in Canada's province of British Columbia. Under specific full load operating conditions, one unit experiences power and pressure fluctuations at 0.46 Hz. The aim of the paper is to present a methodology allowing prediction of this prototype's instability frequency from investigations on the reduced scale model. A new hydro acoustic vortex rope model has been developed in SIMSEN software, taking into account the energy dissipation due to the thermodynamic exchange between the gas and the surrounding liquid. A combination of measurements, CFD simulations and computation of eigenmodes of the reduced scale model installed on test rig, allows the accurate calibration of the vortex rope model parameters at the model scale. Then, transposition of parameters to the prototype according to similitude laws is applied and stability analysis of the power plant is performed. The eigenfrequency of 0.39 Hz related to the first eigenmode of the power plant is determined to be unstable. Predicted frequency of the full load power and pressure fluctuations at the unit unstable operating point is found to be in general agreement with the prototype measurements.
Wake Characteristics of a Flapping Wing Optimized for both Aerial and Aquatic Flight
NASA Astrophysics Data System (ADS)
Izraelevitz, Jacob; Kotidis, Miranda; Triantafyllou, Michael
2017-11-01
Multiple aquatic bird species (including murres, puffins, and other auks) employ a single actuator to propel themselves in two different fluid media: both flying and swimming using primarily their flapping wings. This impressive design compromise could be adopted by engineered implementations of dual aerial/aquatic robotic platforms, as it offers an existence proof for favorable flow physics. We discuss one realization of a 3D flapping wing actuation system for use in both air and water. The wing oscillates by the root and employs an active in-line motion degree-of-freedom. An experiment-coupled optimization routine generates the wing trajectories, controlling the unsteady forces throughout each flapping cycle. We elucidate the wakes of these wing trajectories using dye visualization, correlating the wake vortex structures with simultaneous force measurements. After optimization, the wing generates the large force envelope necessary for propulsion in both fluid media, and furthermore, demonstrate improved control over the unsteady wake.
Helical vortices: viscous dynamics and instability
NASA Astrophysics Data System (ADS)
Rossi, Maurice; Selcuk, Can; Delbende, Ivan; Ijlra-Upmc Team; Limsi-Cnrs Team
2014-11-01
Understanding the dynamical properties of helical vortices is of great importance for numerous applications such as wind turbines, helicopter rotors, ship propellers. Locally these flows often display a helical symmetry: fields are invariant through combined axial translation of distance Δz and rotation of angle θ = Δz / L around the same z-axis, where 2 πL denotes the helix pitch. A DNS code with built-in helical symmetry has been developed in order to compute viscous quasi-steady basic states with one or multiple vortices. These states will be characterized (core structure, ellipticity, ...) as a function of the pitch, without or with an axial flow component. The instability modes growing in the above base flows and their growth rates are investigated by a linearized version of the DNS code coupled to an Arnoldi procedure. This analysis is complemented by a helical thin-cored vortex filaments model. ANR HELIX.
Time-delayed autosynchronous swarm control.
Biggs, James D; Bennet, Derek J; Dadzie, S Kokou
2012-01-01
In this paper a general Morse potential model of self-propelling particles is considered in the presence of a time-delayed term and a spring potential. It is shown that the emergent swarm behavior is dependent on the delay term and weights of the time-delayed function, which can be set to induce a stationary swarm, a rotating swarm with uniform translation, and a rotating swarm with a stationary center of mass. An analysis of the mean field equations shows that without a spring potential the motion of the center of mass is determined explicitly by a multivalued function. For a nonzero spring potential the swarm converges to a vortex formation about a stationary center of mass, except at discrete bifurcation points where the center of mass will periodically trace an ellipse. The analytical results defining the behavior of the center of mass are shown to correspond with the numerical swarm simulations.
NASA Technical Reports Server (NTRS)
Rodgers, R. J.; Latham, T. S.; Krascella, N. L.
1971-01-01
Calculation results are reviewed of the radiant heat transfer characteristics in the fuel and buffer gas regions of a nuclear light bulb engine based on the transfer of energy by thermal radiation from gaseous uranium fuel in a neon vortex, through an internally cooled transparent wall, to seeded hydrogen propellant. The results indicate that the fraction of UV energy incident on the transparent walls increases with increasing power level. For the reference engine power level of 4600 megw, it is necessary to employ space radiators to reject the UV radiated energy absorbed by the transparent walls. This UV energy can be blocked by employing nitric oxide and oxygen seed gases in the fuel and buffer gas regions. However, this results in increased UV absorption in the buffer gas which also requires space radiators to reject the heat load.
Comparison of running and cycling economy in runners, cyclists, and triathletes.
Swinnen, Wannes; Kipp, Shalaya; Kram, Rodger
2018-07-01
Exercise economy is one of the main physiological factors determining performance in endurance sports. Running economy (RE) can be improved with running-specific training, while the improvement of cycling economy (CE) with cycling-specific training is controversial. We investigated whether exercise economy reflects sport-specific skills/adaptations or is determined by overall physiological factors. We compared RE and CE in 10 runners, 9 cyclists and 9 triathletes for running at 12 km/h and cycling at 200 W. Gross rates of oxygen consumption and carbon dioxide production were collected and used to calculate gross metabolic rate in watts for both running and cycling. Runners had better RE than cyclists (917 ± 107 W vs. 1111 ± 159 W) (p < 0.01). Triathletes had intermediate RE values (1004 ± 98 W) not different from runners or cyclists. CE was not different (p = 0.20) between the three groups (runners: 945 ± 60 W; cyclists: 982 ± 44 W; triathletes: 979 ± 54 W). RE can be enhanced with running-specific training, but CE is independent of cycling-specific training.
Relationship between Achilles tendon properties and foot strike patterns in long-distance runners.
Kubo, Keitaro; Miyazaki, Daisuke; Tanaka, Shigeharu; Shimoju, Shozo; Tsunoda, Naoya
2015-01-01
The purpose of this study was to investigate the relationship between Achilles tendon properties and foot strike patterns in long-distance runners. Forty-one highly trained male long-distance runners participated in this study. Elongation of the Achilles tendon and aponeurosis of the medial gastrocnemius muscle were measured using ultrasonography, while the participants performed ramp isometric plantar flexion up to the voluntary maximum. The relationship between the estimated muscle force and tendon elongation during the ascending phase was fit to a linear regression, the slope of which was defined as stiffness. In addition, the cross-sectional area of the Achilles tendon was measured using ultrasonography. Foot strike patterns (forefoot, midfoot and rearfoot) during running were determined at submaximal velocity (18 km · h(-1)) on a treadmill. The number of each foot strike runner was 12 for the forefoot (29.3%), 12 for the midfoot (29.3%) and 17 for the rearfoot (41.5%). No significant differences were observed in the variables measured for the Achilles tendon among the three groups. These results suggested that the foot strike pattern during running did not affect the morphological or mechanical properties of the Achilles tendon in long-distance runners.
Kinematic classification of iliotibial band syndrome in runners.
Grau, S; Krauss, I; Maiwald, C; Axmann, D; Horstmann, T; Best, R
2011-04-01
Several inconsistent causative biomechanical factors are considered to be crucial in the occurrence of iliotibial band syndrome (ITBS). The focus of this study was on assessing differences in the kinematic characteristics between healthy runners [control group (CO)] and runners with ITBS in order to recommend treatment strategies to deal with this injury. Three-dimensional kinematics of barefoot running was used in the biomechanical setup. Both groups were matched with respect to gender, height and weight. After determining drop outs, the final population comprised 36 subjects (26 male and 10 female): 18 CO and 18 ITBS (13 male and five female, each). Kinematic evaluations indicate less hip adduction and frontal range of motion at the hip joint in runners with ITBS. Furthermore, maximum hip flexion velocity and maximum knee flexion velocity were lower in runners with ITBS. Lack of joint coordination, expressed as earlier hip flexion and a tendency toward earlier knee flexion, was found to be another discriminating variable in subjects with ITBS compared with CO subjects. We assume that an increase in range of motion at the hip joint, stretching of the hip abductors, as well as stretching the hamstrings, calf muscles and hip flexors will help treat ITBS. © 2009 John Wiley & Sons A/S.
MOODY, DANNY; HUNTER, IAIN; RIDGE, SARAH; MYRER, J. WILLIAM
2018-01-01
There are many different types of footwear available for runners in today’s market. Many of these shoes claim to help runners run more efficiently by altering an individual’s stride mechanics. Minimalist footwear claims to aid runners run more on their forefeet whereas more traditional footwear provides more cushioning specifically for a heel first landing. The purpose of this paper was to determine if runners, who were accustomed to running in traditional footwear would alter their running mechanics while running acutely in various types of minimalist footwear. Twelve subjects, accustomed to running in traditional 12 mm heel/toe differential footwear, ran in five footwear conditions on a treadmill at a controlled pace for two minutes after warming up in each condition for 5 minutes. While running in 12 mm heel/toe differential footwear compared to barefoot, subjects ran with a significantly longer ground time, a lower stride rate and greater vertical oscillation. There were not any differences in variables when running in the shod conditions despite the varying heel/toe differentials. Running barefoot proved to be different than running in traditional 12 mm drop cushioned footwear. PMID:29795721
Moody, Danny; Hunter, Iain; Ridge, Sarah; Myrer, J William
2018-01-01
There are many different types of footwear available for runners in today's market. Many of these shoes claim to help runners run more efficiently by altering an individual's stride mechanics. Minimalist footwear claims to aid runners run more on their forefeet whereas more traditional footwear provides more cushioning specifically for a heel first landing. The purpose of this paper was to determine if runners, who were accustomed to running in traditional footwear would alter their running mechanics while running acutely in various types of minimalist footwear. Twelve subjects, accustomed to running in traditional 12 mm heel/toe differential footwear, ran in five footwear conditions on a treadmill at a controlled pace for two minutes after warming up in each condition for 5 minutes. While running in 12 mm heel/toe differential footwear compared to barefoot, subjects ran with a significantly longer ground time, a lower stride rate and greater vertical oscillation. There were not any differences in variables when running in the shod conditions despite the varying heel/toe differentials. Running barefoot proved to be different than running in traditional 12 mm drop cushioned footwear.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-28
... new high efficiency turbine runners, replacing runner seals, replacing or modifying head covers; (2) conducting non-destructive examination and possible rehabilitation and modification of shafts; (3...
Remotely replaceable tokamak plasma limiter tiles
Gallix, R.
1987-12-09
U-shaped tiles placed end-to-end over a pair of parallel runners have two rods which engage L-shaped slots. A sliding bar between the runners has grooves with clips to retain the rods pressed into receiving legs of the L-shaped slots in the runners. Sliding the bar in the direction of retaining legs of the L-shaped slots latches the tiles in place over the wall. Resilient contact strips under the parallel sides of the U-shaped tile assure thermal and electrical contact with the wall. 6 figs.
Velocity distribution of women's 30-km cross-country skiing during Olympic Games from 2002-2014.
Erdmann, Wlodzimierz S; Dancewicz-Nosko, Dorota; Giovanis, Vasilios
2017-12-01
Within several investigated endurance sport disciplines the distribution of load of the best competitors has a manner of evenly or slightly rising velocity values. Unfortunately many other competitors have usually diminishing values or when they are very poor they have evenly values. The aim of this study was to investigate distribution of velocity within 30-km cross-country female skiers. Cross-country skiing runs were investigated of Olympic Games 2002-2014 (Salt Lake City, Turin, Vancouver, Sochi). At every race two 15 km or three 10 km loops of the same vertical profile were taken into account. The competitors were divided onto: A - winners, B - medallists, C - competitors who obtained places 4 to 10 at the finish line (medium runners), D - competitors who obtained places 11 to 30 at the finish line (poor runners). Velocity data presented on the web pages of several institutions were utilized. The competitors had their velocity distributed in a manner with usually diminishing values. While comparing velocity of sequential loops with the mean velocity the difference for the poor runners reached the value of almost 6 %, which was too high. There was significant (usually negative) correlation coefficient between values of velocity deviation for the first and second loops and the mean value of velocity for the entire distance for the better runners and mixed, i.e. positive and negative values for the poorer runners. It was postulated investigations of velocity distribution should be introduced in coaching in order to inform competitors about their running. This advise is especially important for the poorer runners. Up to now cross country skiers run for themselves. It should be discussed whether the tactics used by road and track runners, i.e. running with pace makers, can be introduced in cross country skiing. Also the use of a drone during training can be used in order to maintain proper pace.
Runners in their forties dominate ultra-marathons from 50 to 3,100 miles
Zingg, Matthias Alexander; Rüst, Christoph Alexander; Rosemann, Thomas; Lepers, Romuald; Knechtle, Beat
2014-01-01
OBJECTIVES: This study investigated performance trends and the age of peak running speed in ultra-marathons from 50 to 3,100 miles. METHODS: The running speed and age of the fastest competitors in 50-, 100-, 200-, 1,000- and 3,100-mile events held worldwide from 1971 to 2012 were analyzed using single- and multi-level regression analyses. RESULTS: The number of events and competitors increased exponentially in 50- and 100-mile events. For the annual fastest runners, women improved in 50-mile events, but not men. In 100-mile events, both women and men improved their performance. In 1,000-mile events, men became slower. For the annual top ten runners, women improved in 50- and 100-mile events, whereas the performance of men remained unchanged in 50- and 3,100-mile events but improved in 100-mile events. The age of the annual fastest runners was approximately 35 years for both women and men in 50-mile events and approximately 35 years for women in 100-mile events. For men, the age of the annual fastest runners in 100-mile events was higher at 38 years. For the annual fastest runners of 1,000-mile events, the women were approximately 43 years of age, whereas for men, the age increased to 48 years of age. For the annual fastest runners of 3,100-mile events, the age in women decreased to 35 years and was approximately 39 years in men. CONCLUSION: The running speed of the fastest competitors increased for both women and men in 100-mile events but only for women in 50-mile events. The age of peak running speed increased in men with increasing race distance to approximately 45 years in 1,000-mile events, whereas it decreased to approximately 39 years in 3,100-mile events. In women, the upper age of peak running speed increased to approximately 51 years in 3,100-mile events. PMID:24626948
Altered neuroendocrine regulation of gonadotropin secretion in women distance runners.
Veldhuis, J D; Evans, W S; Demers, L M; Thorner, M O; Wakat, D; Rogol, A D
1985-09-01
We tested the hypothesis that the neuroendocrine control of gonadotropin secretion is altered in certain women distance runners with secondary amenorrhea. To this end, we quantitated the frequency and amplitude of spontaneous pulsatile LH secretion during a 24-h interval in nine such women. The ability of the pituitary gland to release LH normally was assessed by administration of graded bolus doses of GnRH during the subsequent 8 h. Compared to normally menstruating women, six of nine amenorrheic distance runners had a distinct reduction in spontaneous LH pulse frequency, with one, three, six, five, four, or two pulses per 24 h (normal, 8-15 pulses/24 h). This reduction in LH pulse frequency occurred without any significant alterations in plasma concentrations of estradiol and free testosterone or 24-h integrated serum concentrations of LH, FSH, or PRL. Moreover, in long-distance runners, the capacity of the pituitary gland to release LH was normal or accentuated in response to exogenous pulses of GnRH. In the six women athletes with diminished spontaneous LH pulsatility, acute ovarian responsiveness also was normal, since serum estradiol concentrations increased normally in response to the GnRH-induced LH pulses. Although long-distance runners had significantly lower estimated percent body fat compared to control women, specific changes in pulsatile gonadotropin release did not correlate with degree of body leanness. In summary, certain long-distance runners with secondary amenorrhea or severe oligomenorrhea have unambiguously decreased spontaneous LH pulse frequency with intact pituitary responsiveness to GnRH. This neuroendocrine disturbance may be relevant to exercise-associated amenorrhea, since pulsatile LH release is a prerequisite for cyclic ovarian function. We speculate that such alterations in pulsatile LH release in exercising women reflect an adaptive response of the hypothalamic pulse generator controlling the intermittent GnRH signal to the pituitary gland. The basis for amenorrhea in the remaining runners who have normal pulsatile properties of LH release is not known.
Malisoux, Laurent; Chambon, Nicolas; Delattre, Nicolas; Gueguen, Nils; Urhausen, Axel; Theisen, Daniel
2016-04-01
This randomised controlled trial investigated if the usage of running shoes with a motion control system modifies injury risk in regular leisure-time runners compared to standard shoes, and if this influence depends on foot morphology. Recreational runners (n=372) were given either the motion control or the standard version of a regular running shoe model and were followed up for 6 months regarding running activity and injury. Foot morphology was analysed using the Foot Posture Index method. Cox regression analyses were used to compare injury risk between the two groups, based on HRs and their 95% CIs, controlling for potential confounders. Stratified analyses were conducted to evaluate the effect of motion control system in runners with supinated, neutral and pronated feet. The overall injury risk was lower among the participants who had received motion control shoes (HR=0.55; 95% CI 0.36 to 0.85) compared to those receiving standard shoes. This positive effect was only observed in the stratum of runners with pronated feet (n=94; HR=0.34; 95% CI 0.13 to 0.84); there was no difference in runners with neutral (n=218; HR=0.78; 95% CI 0.44 to 1.37) or supinated feet (n=60; HR=0.59; 95% CI 0.20 to 1.73). Runners with pronated feet using standard shoes had a higher injury risk compared to those with neutral feet (HR=1.80; 95% CI 1.01 to 3.22). The overall injury risk was lower in participants who had received motion control shoes. Based on secondary analysis, those with pronated feet may benefit most from this shoe type. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Development of low head Kaplan turbine for power station rehabilitation project
NASA Astrophysics Data System (ADS)
Lim, S. M.; Ohtake, N.; Kurosawa, S.; Suzuki, T.; Yamasaki, T.; Nishi, H.
2012-11-01
This paper presents the latest Kaplan turbine rehabilitation project for Funagira Power Station in Japan completed by J-POWER Group in collaboration with Toshiba Corporation. Area of rehabilitation was restricted to guide vane and runner. The main goal of the rehabilitation project was to expand the operating range of the existing turbine in terms of discharge and power with high operational stability, low noise as well as high cavitation performance. Computational Fluids Dynamics and model test were used to optimize the shape of guide vane and runner in development stage. Finally, field tests and runner inspection were carried out to confirm the performance of the new turbine. It was found that the new turbine has excellent performance in efficiency, power output, operational stability compared with existing turbine. Moreover, no sign of cavitation on the runner blade surface was observed after 5078 hours of operation near 100% load.
Long-distance running, bone density, and osteoarthritis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lane, N.E.; Bloch, D.A.; Jones, H.H.
Forty-one long-distance runners aged 50 to 72 years were compared with 41 matched community controls to examine associations of repetitive, long-term physical impact (running) with osteoarthritis and osteoporosis. Roentgenograms of hands, lateral lumbar spine, and knees were assessed without knowledge of running status. A computed tomographic scan of the first lumbar vertebra was performed to quantitate bone mineral content. Runners, both male and female, have approximately 40% more bone mineral than matched controls. Female runners, but not male runners, appear to have somewhat more sclerosis and spur formation in spine and weight-bearing knee x-ray films, but not in hand x-raymore » films. There were no differences between groups in joint space narrowing, crepitation, joint stability, or symptomatic osteoarthritis. Running is associated with increased bone mineral but not, in this cross-sectional study, with clinical osteoarthritis.« less
Sports drink consumption and dental erosion among amateur runners.
Antunes, Leonardo S; Veiga, Lais; Nery, Victor S; Nery, Caio C; Antunes, Lívia A
2017-01-01
This cross-sectional study assessed the prevalence and potential risk factors for dental erosion in amateur athletes at running events. After a sample calculation, 108 runners from the state of Rio de Janeiro, Brazil, were selected and examined for dental wear by a single trained and calibrated evaluator (kappa = 1.00). To identify risk factors, the runners were interviewed by using a standardized, semi-structured questionnaire. The average (SD) age of the runners was 34.2 (11.45), and the prevalence of dental erosion was 19.4%. Gastroesophageal reflux, running frequency per week, and time expended during competition were associated with dental erosion (P < 0.05). The association between use of isotonic drinks and dental erosion was not significant (P > 0.05). In conclusion, dental erosion was not associated with use of isotonic drinks. However, frequency of exercise per week and gastroesophageal reflux were risk factors for dental erosion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Look, Nicole; Arellano, Christopher J.; Grabowski, Alena M.
2013-12-15
In this paper, we study dynamic stability during running, focusing on the effects of speed, and the use of a leg prosthesis. We compute and compare the maximal Lyapunov exponents of kinematic time-series data from subjects with and without unilateral transtibial amputations running at a wide range of speeds. We find that the dynamics of the affected leg with the running-specific prosthesis are less stable than the dynamics of the unaffected leg and also less stable than the biological legs of the non-amputee runners. Surprisingly, we find that the center-of-mass dynamics of runners with two intact biological legs are slightlymore » less stable than those of runners with amputations. Our results suggest that while leg asymmetries may be associated with instability, runners may compensate for this effect by increased control of their center-of-mass dynamics.« less
Foot-strike haemolysis in an ultramarathon runner.
Fazal, Abid A; Whittemore, Mary S; DeGeorge, Katharine C
2017-12-13
This case report describes mild anaemia and intravascular haemolysis in an otherwise healthy 41-year-old ultramarathon runner. In long-distance endurance athletes, trace gastrointestinal bleeding and plasma volume expansion are recognised sources of mild anaemia, often found incidentally. However, repetitive forceful foot striking can lead to blood cell lysis in the feet, resulting in a mild macrocytic anaemia and intravascular haemolysis, as was demonstrated in the patient described herein. Mild anaemia in runners, often called 'runner's pseudoanaemia', is typically clinically insignificant and does not require intervention. However, an unexplained anaemia can cause undue worry for otherwise healthy patients and lead to costly further testing, providing an argument against routine testing with complete blood counts in healthy, asymptomatic patients. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Gas Core Nuclear Rocket Feasibility Project
NASA Technical Reports Server (NTRS)
Howe, S. D.; DeVolder, B.; Thode, L.; Zerkle, D.
1997-01-01
The next giant leap for mankind will be the human exploration of Mars. Almost certainly within the next thirty years, a human crew will brave the isolation, the radiation, and the lack of gravity to walk on and explore the Red planet. However, because the mission distances and duration will be hundreds of times greater than the lunar missions, a human crew will face much greater obstacles and a higher risk than those experienced during the Apollo program. A single solution to many of these obstacles is to dramatically decrease the mission duration by developing a high performance propulsion system. The gas core nuclear rocket (GCNR) has the potential to be such a system. The gas core concept relies on the use of fluid dynamic forces to create and maintain a vortex. The vortex is composed of a fissile material which will achieve criticality and produce high power levels. By radiatively coupling to the surrounding fluids, extremely high temperatures in the propellant and, thus, high specific impulses can be generated. The ship velocities enabled by such performance may allow a 9 month round trip, manned Mars mission to be considered. Alternatively, one might consider slightly longer missions in ships that are heavily shielded against the intense Galactic Cosmic Ray flux to further reduce the radiation dose to the crew. The current status of the research program at the Los Alamos National Laboratory into the gas core nuclear rocket feasibility will be discussed.
Running Economy: Neuromuscular and Joint Stiffness Contributions in Trained Runners.
Tam, Nicholas; Tucker, Ross; Santos-Concejero, Jordan; Prins, Danielle; Lamberts, Robert P
2018-05-29
It is debated whether running biomechanics make good predictors of running economy, with little known information about the neuromuscular and joint stiffness contributions to economical running gait. The aim of this study was to understand the relationship between certain neuromuscular and spatiotemporal biomechanical factors associated with running economy. Thirty trained runners performed a 6-minute constant-speed running set at 3.3 m∙s -1 , where oxygen consumption was assessed. Overground running trials were also performed at 3.3 m∙s -1 to assess kinematics, kinetics and muscle activity. Spatiotemporal gait variables, joint stiffness, pre-activation and stance phase muscle activity (gluteus medius; rectus femoris (RF); biceps femoris(BF); peroneus longus (PL); tibialis anterior (TA); gastrocnemius lateralis and medius (LG and MG) were variables of specific interest and thus determined. Additionally, pre-activation and ground contact of agonist:antagonist co-activation were calculated. More economical runners presented with short ground contact times (r=0.639, p<0.001) and greater strides frequencies (r=-0.630, p<0.001). Lower ankle and greater knee stiffness were associated with lower oxygen consumption (r=0.527, p=0.007 & r=0.384, p=0.043, respectively). Only LG:TA co-activation during stance were associated with lower oxygen cost of transport (r=0.672, p<0.0001). Greater muscle pre-activation and bi-articular muscle activity during stance were associated with more economical runners. Consequently, trained runners who exhibit greater neuromuscular activation prior to and during ground contact, in turn optimise spatiotemporal variables and joint stiffness, will be the most economical runners.
Shorter Ground Contact Time and Better Running Economy: Evidence From Female Kenyan Runners.
Mooses, Martin; Haile, Diresibachew W; Ojiambo, Robert; Sang, Meshack; Mooses, Kerli; Lane, Amy R; Hackney, Anthony C
2018-06-25
Mooses, M, Haile, DW, Ojiambo, R, Sang, M, Mooses, K, Lane, AR, and Hackney, AC. Shorter ground contact time and better running economy: evidence from female Kenyan runners. J Strength Cond Res XX(X): 000-000, 2018-Previously, it has been concluded that the improvement in running economy (RE) might be considered as a key to the continued improvement in performance when no further increase in V[Combining Dot Above]O2max is observed. To date, RE has been extensively studied among male East African distance runners. By contrast, there is a paucity of data on the RE of female East African runners. A total of 10 female Kenyan runners performed 3 × 1,600-m steady-state run trials on a flat outdoor clay track (400-m lap) at the intensities that corresponded to their everyday training intensities for easy, moderate, and fast running. Running economy together with gait characteristics was determined. Participants showed moderate to very good RE at the first (202 ± 26 ml·kg·km) and second (188 ± 12 ml·kg·km) run trials, respectively. Correlation analysis revealed significant relationship between ground contact time (GCT) and RE at the second run (r = 0.782; p = 0.022), which represented the intensity of anaerobic threshold. This study is the first to report the RE and gait characteristics of East African female athletes measured under everyday training settings. We provided the evidence that GCT is associated with the superior RE of the female Kenyan runners.
A Computer Model of Drafting Effects on Collective Behavior in Elite 10,000-m Runners.
Trenchard, Hugh; Renfree, Andrew; Peters, Derek M
2017-03-01
Drafting in cycling influences collective behavior of pelotons. Although evidence for collective behavior in competitive running events exists, it is not clear if this results from energetic savings conferred by drafting. This study modeled the effects of drafting on behavior in elite 10,000-m runners. Using performance data from a men's elite 10,000-m track running event, computer simulations were constructed using Netlogo 5.1 to test the effects of 3 different drafting quantities on collective behavior: no drafting, drafting to 3 m behind with up to ~8% energy savings (a realistic running draft), and drafting up to 3 m behind with up to 38% energy savings (a realistic cycling draft). Three measures of collective behavior were analyzed in each condition: mean speed, mean group stretch (distance between first- and last-placed runner), and runner-convergence ratio (RCR), which represents the degree of drafting benefit obtained by the follower in a pair of coupled runners. Mean speeds were 6.32 ± 0.28, 5.57 ± 0.18, and 5.51 ± 0.13 m/s in the cycling-draft, runner-draft, and no-draft conditions, respectively (all P < .001). RCR was lower in the cycling-draft condition but did not differ between the other 2. Mean stretch did not differ between conditions. Collective behaviors observed in running events cannot be fully explained through energetic savings conferred by realistic drafting benefits. They may therefore result from other, possibly psychological, processes. The benefits or otherwise of engaging in such behavior are as yet unclear.
Cardiac and renal function in a large cohort of amateur marathon runners.
Hewing, Bernd; Schattke, Sebastian; Spethmann, Sebastian; Sanad, Wasiem; Schroeckh, Sabrina; Schimke, Ingolf; Halleck, Fabian; Peters, Harm; Brechtel, Lars; Lock, Jürgen; Baumann, Gert; Dreger, Henryk; Borges, Adrian C; Knebel, Fabian
2015-03-21
Participation of amateur runners in endurance races continues to increase. Previous studies of marathon runners have raised concerns about exercise-induced myocardial and renal dysfunction and damage. In our pooled analysis, we aimed to characterize changes of cardiac and renal function after marathon running in a large cohort of mostly elderly amateur marathon runners. A total of 167 participants of the Berlin-Marathon (female n = 89, male n = 78; age = 50.3 ± 11.4 years) were included and cardiac and renal function was analyzed prior to, immediately after and 2 weeks following the race by echocardiography and blood tests (including cardiac troponin T, NT-proBNP and cystatin C). Among the runners, 58% exhibited a significant increase in cardiac biomarkers after completion of the marathon. Overall, the changes in echocardiographic parameters for systolic or diastolic left and right ventricular function did not indicate relevant myocardial dysfunction. Notably, 30% of all participants showed >25% decrease in cystatin C-estimated glomerular filtration rate (GFR) from baseline directly after the marathon; in 8%, we observed a decline of more than 50%. All cardiac and renal parameters returned to baseline ranges within 2 weeks after the marathon. The increase in cardiac biomarkers after completing a marathon was not accompanied by relevant cardiac dysfunction as assessed by echocardiography. After the race, a high proportion of runners experienced a decrease in cystatin C-estimated GFR, which is suggestive of transient, exercise-related alteration of renal function. However, we did not observe persistent detrimental effects on renal function.
Bone stress in runners with tibial stress fracture.
Meardon, Stacey A; Willson, John D; Gries, Samantha R; Kernozek, Thomas W; Derrick, Timothy R
2015-11-01
Combinations of smaller bone geometry and greater applied loads may contribute to tibial stress fracture. We examined tibial bone stress, accounting for geometry and applied loads, in runners with stress fracture. 23 runners with a history of tibial stress fracture & 23 matched controls ran over a force platform while 3-D kinematic and kinetic data were collected. An elliptical model of the distal 1/3 tibia cross section was used to estimate stress at 4 locations (anterior, posterior, medial and lateral). Inner and outer radii for the model were obtained from 2 planar x-ray images. Bone stress differences were assessed using two-factor ANOVA (α=0.05). Key contributors to observed stress differences between groups were examined using stepwise regression. Runners with tibial stress fracture experienced greater anterior tension and posterior compression at the distal tibia. Location, but not group, differences in shear stress were observed. Stepwise regression revealed that anterior-posterior outer diameter of the tibia and the sagittal plane bending moment explained >80% of the variance in anterior and posterior bone stress. Runners with tibial stress fracture displayed greater stress anteriorly and posteriorly at the distal tibia. Elevated tibial stress was associated with smaller bone geometry and greater bending moments about the medial-lateral axis of the tibia. Future research needs to identify key running mechanics associated with the sagittal plane bending moment at the distal tibia as well as to identify ways to improve bone geometry in runners in order to better guide preventative and rehabilitative efforts. Copyright © 2015 Elsevier Ltd. All rights reserved.
Mucha, Matthew D; Caldwell, Wade; Schlueter, Emily L; Walters, Carly; Hassen, Amy
2017-04-01
Determine the association between hip abduction strength and lower extremity running related injury in distance runners. Systematic review. Prospective longitudinal and cross sectional studies that quantified hip abduction strength and provided diagnosis of running related injury in distance runners were included and assessed for quality. Effect size was calculated for between group differences in hip abduction strength. Of the 1841 articles returned in the initial search, 11 studies matched all inclusion criteria. Studies were grouped according to injury: iliotibial band syndrome, patellofemoral pain syndrome, medial tibial stress syndrome, tibial stress fracture, and Achilles tendinopathy, and examined for strength differences between injured and non-injured groups. Meaningful differences were found in the studies examining iliotibial band syndrome. Three of five iliotibial band syndrome articles found weakness in runners with iliotibial band syndrome; two were of strong methodological rigor and both of those found a relationship between weakness and injury. Other results did not form associative or predictive relationships between weakness and injury in distance runners. Hip abduction weakness evaluated by hand held dynamometer may be associated with iliotibial band syndrome in distance runners as suggested by several cross sectional studies but is unclear as a significant factor for the development of patellofemoral pain syndrome, medial tibial stress syndrome, tibial stress fracture or Achilles tendinopathy according to the current literature. Future studies are needed with consistent methodology and inclusion of all distance running populations to determine the significance of hip abduction strength in relationship to lower extremity injury. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Heel Pain in Recreational Runners.
ERIC Educational Resources Information Center
Bazzoli, Allan S.; Pollina, Frank S.
1989-01-01
Provides physicians with the signs, symptoms, and management of heel/sole pain in recreational runners (usually due to plantar fasciitis, Achilles tendinitis, and calcaneal stress fractures). Remedies involve palliative treatment of symptoms, correction of underlying biomechanical problems, and flexibility exercises. (SM)
USDA-ARS?s Scientific Manuscript database
State-wide peanut variety trials were conducted in three Oklahoma locations. Performance of runner, Spanish, and Virginia entries were assessed. Performance of runner varieties depended on location but averages across locations indicate that advanced breeding line ARSOK R47A was the top performer....
Aschmann, André; Knechtle, Beat; Cribari, Marco; Rüst, Christoph Alexander; Onywera, Vincent; Rosemann, Thomas; Lepers, Romuald
2013-01-01
Background Endurance running performance of African (AF) and non-African (NAF) athletes is investigated, with better performances seen for Africans. To date, no study has compared the age of peak performance between AF and NAF runners. The present research is an analysis of the age and running performance of top AF and NAF athletes, using the hypothesis that AF athletes were younger and faster than NAF athletes. Methods Age and performance of male and female AF and NAF athletes in half-marathons and marathons held in Switzerland in 2000–2010 were investigated using single and multilevel hierarchical regression analyses. Results For half-marathons, male NAF runners were older than male AF runners (P = 0.02; NAF, 31.1 years ± 6.4 years versus AF, 26.2 years ± 4.9 years), and their running time was longer (P = 0.02; NAF, 65.3 minutes ± 1.7 minutes versus AF, 64.1 minutes ± 0.9 minutes). In marathons, differences between NAF and AF male runners in age (NAF, 33.0 years ± 4.8 years versus AF, 28.6 years ± 3.8 years; P < 0.01) and running time (NAF, 139.5 minutes ± 5.6 minutes versus AF, 133.3 minutes ± 2.7 minutes; P < 0.01) were more pronounced. There was no difference in age (NAF, 31.0 years ± 7.0 years versus AF, 26.7 years ± 6.0 years; P > 0.05) or running time (NAF, 75.0 minutes ± 3.7 minutes versus AF, 75.6 minutes ± 5.3 minutes; P > 0.05) between NAF and AF female half-marathoners. For marathoners, NAF women were older than AF female runners (P = 0.03; NAF, 31.6 years ± 4.8 years versus AF, 27.8 years ± 5.3 years), but their running times were similar (NAF, 162.4 minutes ± 7.2 minutes versus AF, 163.0 minutes ± 7.0 minutes; P > 0.05). Conclusion In Switzerland, the best AF male half-marathoners and marathoners were younger and faster than the NAF counterpart runners. In contrast to the results seen in men, AF and NAF female runners had similar performances. Future studies need to investigate performance and age of AF and NAF marathoners in the World Marathon Majors Series. PMID:24379724
Malisoux, Laurent; Chambon, Nicolas; Urhausen, Axel; Theisen, Daniel
2016-11-01
Modern running shoes are available in a wide range of heel-to-toe drops (ie, the height difference between the forward and rear parts of the inside of the shoe). While shoe drop has been shown to influence strike pattern, its effect on injury risk has never been investigated. Therefore, the reasons for such variety in this parameter are unclear. The first aim of this study was to determine whether the drop of standard cushioned running shoes influences running injury risk. The secondary aim was to investigate whether recent running regularity modifies the relationship between shoe drop and injury risk. Randomized controlled trial; Level of evidence, 1. Leisure-time runners (N = 553) were observed for 6 months after having received a pair of shoes with a heel-to-toe drop of 10 mm (D10), 6 mm (D6), or 0 mm (D0). All participants reported their running activities and injuries (time-loss definition, at least 1 day) in an electronic system. Cox regression analyses were used to compare injury risk between the 3 groups based on hazard rate ratios (HRs) and their 95% CIs. A stratified analysis was conducted to evaluate the effect of shoe drop in occasional runners (<6 months of weekly practice over the previous 12 months) versus regular runners (≥6 months). The overall injury risk was not different among the participants who had received the D6 (HR, 1.30; 95% CI, 0.86-1.98) or D0 (HR, 1.17; 95% CI, 0.76-1.80) versions compared with the D10 shoes. After stratification according to running regularity, low-drop shoes (D6 and D0) were found to be associated with a lower injury risk in occasional runners (HR, 0.48; 95% CI, 0.23-0.98), whereas these shoes were associated with a higher injury risk in regular runners (HR, 1.67; 95% CI, 1.07-2.62). Overall, injury risk was not modified by the drop of standard cushioned running shoes. However, low-drop shoes could be more hazardous for regular runners, while these shoes seem to be preferable for occasional runners to limit injury risk. © 2016 The Author(s).
Damsted, Camma; Parner, Erik Thorlund; Sørensen, Henrik; Malisoux, Laurent; Nielsen, Rasmus Oestergaard
2017-11-06
Participation in half-marathon has been steeply increasing during the past decade. In line, a vast number of half-marathon running schedules has surfaced. Unfortunately, the injury incidence proportion for half-marathoners has been found to exceed 30% during 1-year follow-up. The majority of running-related injuries are suggested to develop as overuse injuries, which leads to injury if the cumulative training load over one or more training sessions exceeds the runners' load capacity for adaptive tissue repair. Owing to an increase of load capacity along with adaptive running training, the runners' running experience and pace abilities can be used as estimates for load capacity. Since no evidence-based knowledge exist of how to plan appropriate half-marathon running schedules considering the level of running experience and running pace, the aim of ProjectRun21 is to investigate the association between running experience or running pace and the risk of running-related injury. Healthy runners using Global Positioning System (GPS) watch between 18 and 65 years will be invited to participate in this 14-week prospective cohort study. Runners will be allowed to self-select one of three half-marathon running schedules developed for the study. Running data will be collected objectively by GPS. Injury will be based on the consensus-based time loss definition by Yamato et al.: "Running-related (training or competition) musculoskeletal pain in the lower limbs that causes a restriction on or stoppage of running (distance, speed, duration, or training) for at least 7 days or 3 consecutive scheduled training sessions, or that requires the runner to consult a physician or other health professional". Running experience and running pace will be included as primary exposures, while the exposure to running is pre-fixed in the running schedules and thereby conditioned by design. Time-to-event models will be used for analytical purposes. ProjectRun21 will examine if particular subgroups of runners with certain running experiences and running paces seem to sustain more running-related injuries compared with other subgroups of runners. This will enable sport coaches, physiotherapists as well as the runners to evaluate their injury risk of taking up a 14-week running schedule for half-marathon.
... you want to run over a period of time. If you're used to only running a mile or so, don't try to go out and suddenly run 5 miles. Work up to it with a series of intermediate steps. If you've had runner's ...
Mathematical, numerical and experimental analysis of the swirling flow at a Kaplan runner outlet
NASA Astrophysics Data System (ADS)
Muntean, S.; Ciocan, T.; Susan-Resiga, R. F.; Cervantes, M.; Nilsson, H.
2012-11-01
The paper presents a novel mathematical model for a-priori computation of the swirling flow at Kaplan runners outlet. The model is an extension of the initial version developed by Susan-Resiga et al [1], to include the contributions of non-negligible radial velocity and of the variable rothalpy. Simple analytical expressions are derived for these additional data from three-dimensional numerical simulations of the Kaplan turbine. The final results, i.e. velocity components profiles, are validated against experimental data at two operating points, with the same Kaplan runner blades opening, but variable discharge.
Running: Improving Form to Reduce Injuries.
2015-08-01
Running is often perceived as a good option for "getting into shape," with little thought given to the form, or mechanics, of running. However, as many as 79% of all runners will sustain a running-related injury during any given year. If you are a runner-casual or serious-you should be aware that poor running mechanics may contribute to these injuries. A study published in the August 2015 issue of JOSPT reviewed the existing research to determine whether running mechanics could be improved, which could be important in treating running-related injuries and helping injured runners return to pain-free running.
Software for Automated Reading of STEP Files by I-DEAS(trademark)
NASA Technical Reports Server (NTRS)
Pinedo, John
2003-01-01
A program called "readstep" enables the I-DEAS(tm) computer-aided-design (CAD) software to automatically read Standard for the Exchange of Product Model Data (STEP) files. (The STEP format is one of several used to transfer data between dissimilar CAD programs.) Prior to the development of "readstep," it was necessary to read STEP files into I-DEAS(tm) one at a time in a slow process that required repeated intervention by the user. In operation, "readstep" prompts the user for the location of the desired STEP files and the names of the I-DEAS(tm) project and model file, then generates an I-DEAS(tm) program file called "readstep.prg" and two Unix shell programs called "runner" and "controller." The program "runner" runs I-DEAS(tm) sessions that execute readstep.prg, while "controller" controls the execution of "runner" and edits readstep.prg if necessary. The user sets "runner" and "controller" into execution simultaneously, and then no further intervention by the user is required. When "runner" has finished, the user should see only parts from successfully read STEP files present in the model file. STEP files that could not be read successfully (e.g., because of format errors) should be regenerated before attempting to read them again.
Dissociation between running economy and running performance in elite Kenyan distance runners.
Mooses, Martin; Mooses, Kerli; Haile, Diresibachew Wondimu; Durussel, Jérôme; Kaasik, Priit; Pitsiladis, Yannis Paul
2015-01-01
The purpose of this study was to investigate the relationship between running economy (RE) and performance in a homogenous group of competitive Kenyan distance runners. Maximal aerobic capacity (VO2max) (68.8 ± 3.8 ml∙kg(-1)∙min(-1)) was determined on a motorised treadmill in 32 Kenyan (25.3 ± 5.0 years; IAAF performance score: 993 ± 77 p) distance runners. Leg anthropometry was assessed and moment arm of the Achilles tendon determined. While Achilles moment arm was associated with better RE (r(2) = 0.30, P = 0.003) and upper leg length, total leg length and total leg length to body height ratio were correlated with running performance (r = 0.42, P = 0.025; r = 0.40, P = 0.030 and r = 0.38, P = 0.043, respectively), RE and maximal time on treadmill (t(max)) were not associated with running performance (r = -0.01, P = 0.965; r = 0.27; P = 0.189, respectively) in competitive Kenyan distance runners. The dissociation between RE and running performance in this homogenous group of runners would suggest that RE can be compensated by other factors to maintain high performance levels and is in line with the idea that RE is only one of many factors explaining elite running performance.
Sulowska, Iwona; Oleksy, Łukasz; Mika, Anna; Bylina, Dorota; Sołtan, Jarosław
2016-01-01
The objective of this study was to evaluate the influence of two kinds of plantar short foot muscles exercise on foot posture and fundamental movement patterns in long-distance runners. A parallel group non-blinded trial with 6-week follow-up. Twenty five long-distance runners aged 22-35 years. They were divided into two groups. In group 1 (n = 13) subjects performed the exercise "Vele's Forward Lean" and "Reverse Tandem Gait" and in Group 2 (n = 12) the "Short Foot Exercise." The runners performed the exercises daily for 6 weeks. The Foot Posture Index (FPI-6) and The Functional Movement Screen (FMS) tests were performed twice: at baseline and after 6 weeks of the exercise. A significant improvement was observed in FPI -6 (talar head palpation in Group 1, and inversion/eversion of the calcaneus in Group 2). Also in Group 1 a significant improvement was noted in FMS tests: deep squat, active straight leg raise and in total score. Short foot muscles strengthening exercises have beneficial effect on functional movement patterns and on foot posture, therefore they should be included as a part of daily training program of runners. Australian New Zealand Clinical Trials Registry ACTRN12615001200572.
Serum lipid levels and steroidal hormones in women runners with irregular menses.
Thompson, D L; Snead, D B; Seip, R L; Weltman, J Y; Rogol, A D; Weltman, A
1997-02-01
This study compared the lipid profile of women runners with menstrual cycle irregularities with their normally menstruating counterparts. Relationships among selected steroid hormones and serum lipid levels in 10 eumenorrheic (EU) and 8 oligo-/amenorrheic (O/A) women runners and 6 eumenorrheic controls (CON) were examined. Serum 17 beta-estradiol (E2), progesterone (Prog), and dehydroepiandrosterone-sulfate (DHEAS) concentrations were determined in daily blood samples for 21 days, and integrated concentrations were calculated. Fasting blood samples were analyzed for total cholesterol (TC), low-density lipoprotein cholesterol (LDL-C), high-density lipoprotein cholesterol (HDL-C), HDL2, HDL3, triglycerides (Trig), and apolipoproteins A-1, A-II, and B. The O/A group had significantly lower E2 and Prog than EU or CON groups. Women in the CON group had lower HDL-C and HDL3 than the runners. With all women grouped together, E2 was not significantly correlated with any measured blood lipid parameters. On the other hand, DHEAS was significantly correlated with HDL-C, HDL2, and apolipoprotein A-I. These data demonstrate that women runners, regardless of menstrual cycle status, exhibit higher HDL-C concentrations than CON and supports previous research reporting a positive association between DHEAS and HDL-C.
Vesterinen, V; Häkkinen, K; Hynynen, E; Mikkola, J; Hokka, L; Nummela, A
2013-03-01
The aim of this study was to investigate whether nocturnal heart rate variability (HRV) can be used to predict changes in endurance performance during 28 weeks of endurance training. The training was divided into 14 weeks of basic training (BTP) and 14 weeks of intensive training periods (ITP). Endurance performance characteristics, nocturnal HRV, and serum hormone concentrations were measured before and after both training periods in 28 recreational endurance runners. During the study peak treadmill running speed (Vpeak ) improved by 7.5 ± 4.5%. No changes were observed in HRV indices after BTP, but after ITP, these indices increased significantly (HFP: 1.9%, P=0.026; TP: 1.7%, P=0.007). Significant correlations were observed between the change of Vpeak and HRV indices (TP: r=0.75, P<0.001; HFP: r=0.71, P<0.001; LFP: r=0.69, P=0.01) at baseline during ITP. In order to lead to significant changes in HRV among recreational endurance runners, it seems that moderate- and high-intensity training are needed. This study showed that recreational endurance runners with a high HRV at baseline improved their endurance running performance after ITP more than runners with low baseline HRV. © 2011 John Wiley & Sons A/S.
Predisposing Risk Factors and Stress Fractures in Division I Cross Country Runners.
Giffin, Kaci L; Knight, Kathy B; Bass, Martha A; Valliant, Melinda W
2017-11-11
The purpose of this study was to explore factors associated with increased stress fractures in collegiate cross country runners. Participants in this study were 42 male and female cross country runners at a Division I university. Each athlete completed a questionnaire regarding smoking status, vitamin/mineral intake, previous stress fracture history, birth control usage, menstrual status, and demographic information. Nutritional assessment via a 3-day food record and measurements of whole body, lumbar spine, and hip bone mineral densities (BMD) were also conducted on each athlete. Results indicated that 40% of the female and 35% of the male runners reported a history of stress fracture, and that all of these did not meet the recommended daily energy intake or adequate intakes for calcium or Vitamin D required for their amount of training. Two-tailed t-test found statistically higher incidences of lumbar spine BMD in males and females whose daily calcium and Vitamin D intakes were below minimum requirements as well as for women whose caloric intake was below the required level. When data on the lumbar spine was evaluated, 31% of participants (31.8% of the male and 30% of the female runners) were identified as having osteopenia and 4.8% with osteoporosis. Results warrant a need for future longitudinal studies.
Alcaraz-Ibañez, Manuel; Rodríguez-Pérez, Manuel
2018-03-01
The aim of this work was to identify, synthesize and evaluate the results of randomized controlled trials examining the effects of resistance training on performance indicators in previously trained endurance runners. A database search was carried out in PubMed, Science Direct, OvidSPMedLine, Wiley, Web of Science, ProQuest and Google Scholar. In accordance with the PRISMA checklist, 18 published articles dated prior to May 2016 involving 321 endurance runners were reviewed using the PEDro scale. Resistance training led to general improvements in muscular strength, running economy, muscle power factors, and direct performance in distances between 1,500 and 10,000 m. Such improvements were not accompanied by a significant increase in body mass or signs of overtraining. However, improvements did not occur in all cases, suggesting that they might depend on the specific characteristics of the resistance training applied. Although current evidence supports the effectiveness of resistance training to improve performance in already trained endurance runners, the methodological inconsistencies identified suggest that the results should be interpreted with caution. Future studies ought to investigate the benefits of resistance training in endurance runners while considering the existence of possible differentiated effects based on the specific characteristics of the resistance training carried out.
van Poppel, D; de Koning, J; Verhagen, A P; Scholten-Peeters, G G M
2016-02-01
To determine risk factors for running injuries during the Lage Landen Marathon Eindhoven 2012. Prospective cohort study. Population-based study. This study included 943 runners. Running injuries after the Lage Landen Marathon. Sociodemographic and training-related factors as well as lifestyle factors were considered as potential risk factors and assessed in a questionnaire 1 month before the running event. The association between potential risk factors and injuries was determined, per running distance separately, using univariate and multivariate logistic regression analysis. In total, 154 respondents sustained a running injury. Among the marathon runners, in the univariate model, body mass index ≥ 26 kg/m(2), ≤ 5 years of running experience, and often performing interval training, were significantly associated with running injuries, whereas in the multivariate model only ≤ 5 years of running experience and not performing interval training on a regular basis were significantly associated with running injuries. Among marathon runners, no multivariate model could be created because of the low number of injuries and participants. This study indicates that interval training on a regular basis may be recommended to marathon runners to reduce the risk of injury. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
An, W; Rainbow, M J; Cheung, R T H
2015-01-01
Barefoot running has been proposed to reduce vertical loading rates, which is a risk factor of running injuries. Most of the previous studies evaluated runners on level surfaces. This study examined the effect of surface inclination on vertical loading rates and landing pattern during the first attempt of barefoot running among habitual shod runners. Twenty habitual shod runners were asked to run on treadmill at 8.0 km/h at three inclination angles (0°; +10°; -10°) with and without their usual running shoes. Vertical average rate (VALR) and instantaneous loading rate (VILR) were obtained by established methods. Landing pattern was decided using high-speed camera. VALR and VILR in shod condition were significantly higher (p < 0.001) in declined than in level or inclined treadmill running, but not in barefoot condition (p > 0.382). There was no difference (p > 0.413) in the landing pattern among all surface inclinations. Only one runner demonstrated complete transition to non-heel strike landing in all slope conditions. Reducing heel strike ratio in barefoot running did not ensure a decrease in loading rates (p > 0.15). Conversely, non-heel strike landing, regardless of footwear condition, would result in a softer landing (p < 0.011).
An, W.; Rainbow, M. J.; Cheung, R. T. H.
2015-01-01
Barefoot running has been proposed to reduce vertical loading rates, which is a risk factor of running injuries. Most of the previous studies evaluated runners on level surfaces. This study examined the effect of surface inclination on vertical loading rates and landing pattern during the first attempt of barefoot running among habitual shod runners. Twenty habitual shod runners were asked to run on treadmill at 8.0 km/h at three inclination angles (0°; +10°; −10°) with and without their usual running shoes. Vertical average rate (VALR) and instantaneous loading rate (VILR) were obtained by established methods. Landing pattern was decided using high-speed camera. VALR and VILR in shod condition were significantly higher (p < 0.001) in declined than in level or inclined treadmill running, but not in barefoot condition (p > 0.382). There was no difference (p > 0.413) in the landing pattern among all surface inclinations. Only one runner demonstrated complete transition to non-heel strike landing in all slope conditions. Reducing heel strike ratio in barefoot running did not ensure a decrease in loading rates (p > 0.15). Conversely, non-heel strike landing, regardless of footwear condition, would result in a softer landing (p < 0.011). PMID:26258133
Au, Ivan P H; Lau, Fannie O Y; An, Winko W; Zhang, Janet H; Chen, Tony L; Cheung, Roy T H
2018-02-01
This study investigated the immediate and short-term effects of minimalist shoes (MS) and traditional running shoes (TRS) on vertical loading rates, foot strike pattern and lower limb kinematics in a group of habitual barefoot runners. Twelve habitual barefoot runners were randomly given a pair of MS or TRS and were asked to run with the prescribed shoes for 1 month. Outcome variables were obtained before, immediate after and 1 month after shoe prescription. Average and instantaneous vertical loading rates at the 1-month follow-up were significantly higher than that at the pre-shod session (P < 0.034, η 2 p > 0.474). Foot strike angle in the TRS group was significantly lower than that in the MS group (P = 0.045, η 2 p = 0.585). However, there was no significant time nor shoe effect on overstride, knee and ankle excursion (P > 0.061). Habitual barefoot runners appeared to land with a greater impact during shod running and they tended to have a more rearfoot strike pattern while wearing TRS. Lower limb kinematics were comparable before and after shoe prescription. Longer period of follow-up is suggested to further investigate the footwear effect on the running biomechanics in habitual barefoot runners.
NASA Astrophysics Data System (ADS)
Wilhelm, S.; Balarac, G.; Métais, O.; Ségoufin, C.
2016-11-01
Flow prediction in a bulb turbine draft tube is conducted for two operating points using Unsteady RANS (URANS) simulations and Large Eddy Simulations (LES). The inlet boundary condition of the draft tube calculation is a rotating two dimensional velocity profile exported from a RANS guide vane- runner calculation. Numerical results are compared with experimental data in order to validate the flow field and head losses prediction. Velocity profiles prediction is improved with LES in the center of the draft tube compared to URANS results. Moreover, more complex flow structures are obtained with LES. A local analysis of the predicted flow field using the energy balance in the draft tube is then introduced in order to detect the hydrodynamic instabilities responsible for head losses in the draft tube. In particular, the production of turbulent kinetic energy next to the draft tube wall and in the central vortex structure is found to be responsible for a large part of the mean kinetic energy dissipation in the draft tube and thus for head losses. This analysis is used in order to understand the differences in head losses for different operating points. The numerical methodology could then be improved thanks to an in-depth understanding of the local flow topology.
NASA Technical Reports Server (NTRS)
2010-01-01
Topics covered include: Wirelessly Interrogated Wear or Temperature Sensors; Processing Nanostructured Sensors Using Microfabrication Techniques; Optical Pointing Sensor; Radio-Frequency Tank Eigenmode Sensor for Propellant Quantity Gauging; High-Temperature Optical Sensor; Integral Battery Power Limiting Circuit for Intrinsically Safe Applications; Configurable Multi-Purpose Processor; Squeezing Alters Frequency Tuning of WGM Optical Resonator; Automated Computer Access Request System; Range Safety for an Autonomous Flight Safety System; Fast and Easy Searching of Files in Unisys 2200 Computers; Parachute Drag Model; Evolutionary Scheduler for the Deep Space Network; Modular Habitats Comprising Rigid and Inflatable Modules; More About N2O-Based Propulsion and Breathable-Gas Systems; Ultrasonic/Sonic Rotary-Hammer Drills; Miniature Piezoelectric Shaker for Distribution of Unconsolidated Samples to Instrument Cells; Lunar Soil Particle Separator; Advanced Aerobots for Scientific Exploration; Miniature Bioreactor System for Long-Term Cell Culture; Electrochemical Detection of Multiple Bioprocess Analytes; Fabrication and Modification of Nanoporous Silicon Particles; High-Altitude Hydration System; Photon Counting Using Edge-Detection Algorithm; Holographic Vortex Coronagraph; Optical Structural Health Monitoring Device; Fuel-Cell Power Source Based on Onboard Rocket Propellants; Polar Lunar Regions: Exploiting Natural and Augmented Thermal Environments; Simultaneous Spectral Temporal Adaptive Raman Spectrometer - SSTARS; Improved Speed and Functionality of a 580-GHz Imaging Radar; Bolometric Device Based on Fluxoid Quantization; Algorithms for Learning Preferences for Sets of Objects; Model for Simulating a Spiral Software-Development Process; Algorithm That Synthesizes Other Algorithms for Hashing; Algorithms for High-Speed Noninvasive Eye-Tracking System; and Adapting ASPEN for Orbital Express.
Physiological Changes in Elite Male Distance Runners Training for Olympic Competition.
ERIC Educational Resources Information Center
Martin, D. E.; And Others
1986-01-01
Nine elite male distance runners were evaluated by comprehensive periodic monitoring of selected blood chemistry variables, percent body fat and lean body mass, and cardiopulmonary performance as they prepared for the 1984 Olympic Summer Games. Results are discussed. (MT)
7 CFR 51.2710 - U.S. No. 1 Runner.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946... of shelled Runner type peanut kernels of similar varietal characteristics which are whole and free...
7 CFR 51.2712 - U.S. No. 2 Runner.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946... of shelled Runner type peanut kernels of similar varietal characteristics which may be split or...
Evidence against a 40 degrees C core temperature threshold for fatigue in humans.
Ely, Brett R; Ely, Matthew R; Cheuvront, Samuel N; Kenefick, Robert W; Degroot, David W; Montain, Scott J
2009-11-01
Evidence suggests that core temperatures of approximately 40 degrees C can induce fatigue, although this may be confounded by coincident elevations in skin temperatures and maximal cardiovascular strain. In an observational field study to examine core temperature threshold for fatigue, we investigated whether running performance is impaired when rectal temperature (T(re)) is >40 degrees C and skin temperature remains modest. Seventeen competitive runners (7/10 women/men: 8 km best 1,759 +/- 78/1,531 +/- 60 s) completed 8-km track time trials in cool (WBGT approximately 13 degrees C; n = 6), warm (WBGT approximately 27 degrees C; n = 4), or both (n = 7) conditions. T(re), chest skin temperature, and heart rate were logged continuously; elapsed time was recorded every 200 m. Running velocity for T(re) >40 degrees C was compared with that for T(re) <40 degrees C for each runner. Changes in running velocity over the last 600 m were compared between runners with T(re) >40 degrees C and <40 degrees C. Twelve runners achieved T(re) >40.0 degrees C with >or=600 m remaining (range 600-3,400 m). Average running velocity for T(re) <40 degrees C (282 +/- 27 m/min) was not different from that for T(re) >40 degrees C (279 +/- 28 m/min; P = 0.82). There were no differences in running velocity during the final 600 m between runners with final T(re) >40 degrees C or <40 degrees C (P = 0.16). Chest skin temperature ranged from 30 to 34 degrees C, and heart rate was >95% of age-predicted maximum. Our observation that runners were able to sustain running velocity despite T(re) >40 degrees C is evidence against 40 degrees C representing a "critical" core temperature limit to performance.
Nielsen, Rasmus O; Videbaek, Solvej; Hansen, Mette; Parner, Erik T; Rasmussen, Sten; Langberg, Henning
2016-01-01
The aim of this study was to explore how average weekly running distance, combined with changes in diet habits and reasons to take up running, influence fat mass. Fat mass was assessed by bioelectrical impedance at baseline and after 12 months in 538 novice runners included in a 1-year observational prospective follow-up study. During follow-up, running distance for each participant was continuously measured by GPS while reasons to take up running and diet changes were assessed trough web-based questionnaires. Loss of fat mass was compared between runners covering an average of 5 km or more per week and those running shorter distances. Runners who took up running to lose weight and ran over 5 km per week in average over a one-year period combined with a diet change reduced fat mass by -5.58 kg (95% CI: -8.69; -2.46; P<0.001). Compared with subjects also running over 5 km per week but without diet changes, the mean difference in fat mass between groups was 3.81 kg (95% CI: -5.96; -1.66; P<0.001). A difference of -3.55 kg (95% CI: -5.69; -1.41; P<0.001) was found when comparing with those running less than 5 km per week and making changes to their own diet. An average running distance of more than 5 km per week in runners who took up running to lose weight combined with a targeted diet change seems effective in reducing fat mass over a one-year period among novice runners. Still, randomized controlled trials are needed to better document the effects of self-selected diet changes.
Risk factors for stress fracture among young female cross-country runners.
Kelsey, Jennifer L; Bachrach, Laura K; Procter-Gray, Elizabeth; Nieves, Jeri; Greendale, Gail A; Sowers, Maryfran; Brown, Byron W; Matheson, Kim A; Crawford, Sybil L; Cobb, Kristin L
2007-09-01
To identify risk factors for stress fracture among young female distance runners. Participants were 127 competitive female distance runners, aged 18-26, who provided at least some follow-up data in a randomized trial among 150 runners of the effects of oral contraceptives on bone health. After completing a baseline questionnaire and undergoing bone densitometry, they were followed an average of 1.85 yr. Eighteen participants had at least one stress fracture during follow-up. Baseline characteristics associated (P<0.10) in multivariate analysis with stress fracture occurrence were one or more previous stress fractures (rate ratio [RR] [95% confidence interval]=6.42 (1.80-22.87), lower whole-body bone mineral content (RR=2.70 [1.26-5.88] per 1-SD [293.2 g] decrease), younger chronologic age (RR=1.42 [1.05-1.92] per 1-yr decrease), lower dietary calcium intake (RR=1.11 [0.98-1.25] per 100-mg decrease), and younger age at menarche (RR=1.92 [1.15-3.23] per 1-yr decrease). Although not statistically significant, a history of irregular menstrual periods was also associated with increased risk (RR=3.41 [0.69-16.91]). Training-related factors did not affect risk. The results of this and other studies indicate that risk factors for stress fracture among young female runners include previous stress fractures, lower bone mass, and, although not statistically significant in this study, menstrual irregularity. More study is needed of the associations between stress fracture and age, calcium intake, and age at menarche. Given the importance of stress fractures to runners, identifying preventive measures is of high priority.
Wirnitzer, Katharina; Seyfart, Tom; Leitzmann, Claus; Keller, Markus; Wirnitzer, Gerold; Lechleitner, Christoph; Rüst, Christoph Alexander; Rosemann, Thomas; Knechtle, Beat
2016-01-01
Beneficial and detrimental effects of various vegetarian and vegan diets on the health status are well known. Considering the growing background numbers of vegetarians and vegans, the number of vegetarian and vegan runners is likely to rise, too. Therefore, the Nutrition and Running High Mileage (NURMI) Study was designed as a comparative study to investigate the prevalence of omnivores, vegetarians, and vegans in running events and to detect potential differences in running performance comparing these three subgroups. The NURMI Study will be conducted in three steps following a cross-sectional design. Step 1 will determine epidemiological aspects of endurance runners (any distance) using a short standardized questionnaire. Step 2 will investigate dietary habits and running history from eligible participants (capable of running a half-marathon at least) using an extended standardized questionnaire. Step 3 will collect data after a running event on finishing time and final ranking as well as a post-race rating of perceived exertion, mood status, nutrient and fluid intake during the race. Our study will provide a major contribution to overcome the lack of data on the prevalence and running performance of vegetarian and vegan runners in endurance running events. We estimate the prevalence of vegetarians and vegans participating in a running event to be less compared to the respective proportion of vegetarians and vegans to the general population. Furthermore we will validate the subject's self-assessment of their respective diet. This comparative study may identify possible effects of dietary behavior on running performance und may detect possible differences between the respective subgroups: omnivorous, vegetarian and vegan runners. Trial registration Current controlled trials, ISRCTN73074080.
Excessive exercise habits of runners as new signs of hypertension and arrhythmia.
Kim, Young-Joo; Kim, Chul-Hyun; Park, Kyoung-Min
2016-08-15
Excessive exercise may induce arrhythmia, and this risk is higher in middle-aged people. The study aim was to compare the exercise characteristics of middle-aged runners participating in excessive endurance exercise. The subjects of this study were 552 runners (mean age; 49.0±7.4years) without structural heart disease who performed exercise at least twice per week, had consistently exercised for at least three years, and had finished at least five marathons. The arrhythmia runner group (ARG, n=14) and normal runner group (NRG, n=538) were compared with regard to hemodynamic response, cardiorespiratory fitness level, training history, number of finished races, finishing times, and exercise habits. The mean resting systolic (134.0±15.8mmHg) and diastolic (85.8±10.9mmHg) blood pressure values indicated pre-hypertension, while the mean maximal SBP (213.7±27.4mmHg) values indicated exercise-induced hypertension. The VO2max was significantly higher and the maximal DBP was significantly lower in the ARG than in the NRG (p<0.05). Training history was significantly longer in the ARG than in the NRG (p<0.05), while the number of finished marathons, the finishing times in marathons and the exercise frequency per week didn't differ significantly between the two groups. Exercise intensity was significantly higher in the ARG than in the NRG (p<0.01). Middle-aged long-distance runners showed pre-hypertension and exercise-induced hypertension, and the ARG had higher VO2max values, greater exercise intensities, and longer training histories than the NRG. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Leisure-Time Running Reduces All-Cause and Cardiovascular Mortality Risk
Lee, Duck-chul; Pate, Russell R.; Lavie, Carl J.; Sui, Xuemei; Church, Timothy S.; Blair, Steven N.
2014-01-01
Background Although running is a popular leisure-time physical activity, little is known about the long-term effects of running on mortality. The dose-response relations between running, as well as the change in running behaviors over time and mortality remain uncertain. Objectives We examined the associations of running with all-cause and cardiovascular mortality risks in 55,137 adults, aged 18 to 100 years (mean age, 44). Methods Running was assessed on the medical history questionnaire by leisure-time activity. Results During a mean follow-up of 15 years, 3,413 all-cause and 1,217 cardiovascular deaths occurred. Approximately, 24% of adults participated in running in this population. Compared with non-runners, runners had 30% and 45% lower adjusted risks of all-cause and cardiovascular mortality, respectively, with a 3-year life expectancy benefit. In dose-response analyses, the mortality benefits in runners were similar across quintiles of running time, distance, frequency, amount, and speed, compared with non-runners. Weekly running even <51 minutes, <6 miles, 1-2 times, <506 metabolic equivalent-minutes, or <6 mph was sufficient to reduce risk of mortality, compared with not running. In the analyses of change in running behaviors and mortality, persistent runners had the most significant benefits with 29% and 50% lower risks of all-cause and cardiovascular mortality, respectively, compared with never-runners. Conclusions Running, even 5-10 minutes per day and slow speeds <6 mph, is associated with markedly reduced risks of death from all causes and cardiovascular disease. This study may motivate healthy but sedentary individuals to begin and continue running for substantial and attainable mortality benefits. PMID:25082581
Saeki, Junya; Nakamura, Masatoshi; Nakao, Sayaka; Fujita, Kosuke; Yanase, Ko; Morishita, Katsuyuki; Ichihashi, Noriaki
2017-01-01
A high proportion of flexor digitorum longus attachment is found at the posteromedial border of the tibia, which is the most common location of medial tibial stress syndrome (MTSS). Therefore, plantar flexion strength of the lesser toes could be related to MTSS; however, the relationship between MTSS and muscle strength of the hallux and lesser toes is not yet evaluated due to the lack of quantitative methods. This study investigated the muscle strength characteristics in runners with a history of MTSS by using a newly developed device to measure the muscle strength of the hallux, lesser toes, and ankle. This study comprised 27 collegiate male runner participants (20.0 ± 1.6 years, 172.1 ± 5.1 cm, 57.5 ± 4.0 kg). Maximal voluntary isometric contraction (MVIC) torque of the plantar flexion, dorsiflexion, inversion, and eversion of the ankle were measured by using an electric dynamometer. MVIC torque of the 1st metatarsophalangeal joint (MTPJ) and 2nd-5th MTPJ were measured by using a custom-made torque-measuring device. MVIC torques were compared between runners with and without a history of MTSS. MVIC torque of the 1st MTPJ plantar flexion was significantly higher in runners with a history of MTSS than in those without it. In contrast, there were no significant differences in the MVIC torque values of the 2nd-5th MTPJ plantar flexion and each MVIC torque of the ankle between runners with and without a history of MTSS. A history of MTSS increased the isometric FHL strength.
Metabolic Factors Limiting Performance in Marathon Runners
Rapoport, Benjamin I.
2010-01-01
Each year in the past three decades has seen hundreds of thousands of runners register to run a major marathon. Of those who attempt to race over the marathon distance of 26 miles and 385 yards (42.195 kilometers), more than two-fifths experience severe and performance-limiting depletion of physiologic carbohydrate reserves (a phenomenon known as ‘hitting the wall’), and thousands drop out before reaching the finish lines (approximately 1–2% of those who start). Analyses of endurance physiology have often either used coarse approximations to suggest that human glycogen reserves are insufficient to fuel a marathon (making ‘hitting the wall’ seem inevitable), or implied that maximal glycogen loading is required in order to complete a marathon without ‘hitting the wall.’ The present computational study demonstrates that the energetic constraints on endurance runners are more subtle, and depend on several physiologic variables including the muscle mass distribution, liver and muscle glycogen densities, and running speed (exercise intensity as a fraction of aerobic capacity) of individual runners, in personalized but nevertheless quantifiable and predictable ways. The analytic approach presented here is used to estimate the distance at which runners will exhaust their glycogen stores as a function of running intensity. In so doing it also provides a basis for guidelines ensuring the safety and optimizing the performance of endurance runners, both by setting personally appropriate paces and by prescribing midrace fueling requirements for avoiding ‘the wall.’ The present analysis also sheds physiologically principled light on important standards in marathon running that until now have remained empirically defined: The qualifying times for the Boston Marathon. PMID:20975938
Iron excess in recreational marathon runners.
Mettler, S; Zimmermann, M B
2010-05-01
Iron deficiency and anemia may impair athletic performance, and iron supplements are commonly consumed by athletes. However, iron overload should be avoided because of the possible long-term adverse health effects. We investigated the iron status of 170 male and female recreational runners participating in the Zürich marathon. Iron deficiency was defined either as a plasma ferritin (PF) concentration <15 microg/l (iron depletion) or as the ratio of the concentrations of transferrin receptor (sTfR) to PF (sTfR:log(PF) index) of > or =4.5 (functional iron deficiency). After excluding subjects with elevated C-reactive protein concentrations, iron overload was defined as PF >200 microg/l. Iron depletion was found in only 2 out of 127 men (1.6% of the male study population) and in 12 out of 43 (28.0%) women. Functional iron deficiency was found in 5 (3.9%) and 11 (25.5%) male and female athletes, respectively. Body iron stores, calculated from the sTfR/PF ratio, were significantly higher (P<0.001) among male compared with female marathon runners. Median PF among males was 104 microg/l, and the upper limit of the PF distribution in males was 628 microg/l. Iron overload was found in 19 out of 127 (15.0%) men but only 2 out of 43 in women (4.7%). Gender (male sex), but not age, was a predictor of higher PF (P<0.001). Iron depletion was present in 28% of female runners but in <2% of males, whereas one in six male runners had signs of iron overload. Although iron supplements are widely used by athletes in an effort to increase performance, our findings indicate excess body iron may be common in male recreational runners and suggest supplements should only be used if tests of iron status indicate deficiency.
Increased Prevalence of the IL-6-174C Genetic Polymorphism in Long Distance Swimmers.
Ben-Zaken, Sigal; Meckel, Yoav; Nemet, Dan; Kassem, Eias; Eliakim, Alon
2017-09-01
The IL-6 -174G/C single nucleotide polymorphism (SNP) functionally affects IL-6 activity, with the G-allele associated with increased IL-6 levels. The C-allele was found to be associated with exercise-induced skeletal muscle damage. The aim of the present study was to examine the association between the IL-6 -174G/C polymorphism and athletic performance among elite swimmers and runners. The study sample included 180 track and field athletes and 80 swimmers. Track and field athletes were assigned to three sub-groups: long-distance runners, middle-distance runners and short-distance runners. Swimmers were assigned to two subgroups: long-distance swimmers and short-distance swimmers. The control group consisted of 123 non-athletic healthy individuals. Genomic DNA was extracted from peripheral blood following a standard protocol. Genotyping was performed using polymerase chain reaction (PCR). The CC genotype and C-allele frequency were significantly higher in the long-distance swimmers (18 and 43%, respectively) compared to the long-distance runners (3 and 14%, respectively, p < 0.001); middle-distance runners (4 and 22%, respectively, p < 0.001); and controls (5 and 19%, respectively, p < 0.001). In addition, the CC genotype and C-allele frequency were significantly higher (p < 0.001) in long-distance swimmers compared to short-distance swimmers (18 versus 5% and 43 versus 29% for the CC genotype and C-allele frequency, respectively). The higher frequency of the C-allele and CC genotype among long-distance swimmers suggests that the rarity of exercise-associated rhabdomyolysis among swimmers is probably related to other sports-specific or water-related protective mechanisms. It is possible that swimming selection in talented endurance athletes who are C-allele carriers represents an example of genetically-dependent sports selection.
Increased Prevalence of the IL-6-174C Genetic Polymorphism in Long Distance Swimmers
Ben-Zaken, Sigal; Meckel, Yoav; Nemet, Dan; Kassem, Eias; Eliakim, Alon
2017-01-01
Abstract The IL-6 -174G/C single nucleotide polymorphism (SNP) functionally affects IL-6 activity, with the G-allele associated with increased IL-6 levels. The C-allele was found to be associated with exercise-induced skeletal muscle damage. The aim of the present study was to examine the association between the IL-6 -174G/C polymorphism and athletic performance among elite swimmers and runners. The study sample included 180 track and field athletes and 80 swimmers. Track and field athletes were assigned to three sub-groups: long-distance runners, middle-distance runners and short-distance runners. Swimmers were assigned to two subgroups: long-distance swimmers and short-distance swimmers. The control group consisted of 123 non-athletic healthy individuals. Genomic DNA was extracted from peripheral blood following a standard protocol. Genotyping was performed using polymerase chain reaction (PCR). The CC genotype and C-allele frequency were significantly higher in the long-distance swimmers (18 and 43%, respectively) compared to the long-distance runners (3 and 14%, respectively, p < 0.001); middle-distance runners (4 and 22%, respectively, p < 0.001); and controls (5 and 19%, respectively, p < 0.001). In addition, the CC genotype and C-allele frequency were significantly higher (p < 0.001) in long-distance swimmers compared to short-distance swimmers (18 versus 5% and 43 versus 29% for the CC genotype and C-allele frequency, respectively). The higher frequency of the C-allele and CC genotype among long-distance swimmers suggests that the rarity of exercise-associated rhabdomyolysis among swimmers is probably related to other sports-specific or water-related protective mechanisms. It is possible that swimming selection in talented endurance athletes who are C-allele carriers represents an example of genetically-dependent sports selection. PMID:28828083
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-22
... Unit 3 of the project by rewinding the generator and replacing the turbine runner with a more efficient runner. The proposed upgrade would increase the installed and hydraulic capacities of the project by 5.7...
USDA-ARS?s Scientific Manuscript database
Lariat is a high-oleic runner-type peanut (Arachis hypogaea L. subsp. hypogaea var. hypogaea) that has enhanced Sclerotinia blight and pod rot tolerance when compared to the cultivar Red River Runner. Lariat (experimental designation ARSOK-R35) is the result of a cross between cultivar Red River Ru...
Registration of 'Lariat' peanut
USDA-ARS?s Scientific Manuscript database
'Lariat' is a high-oleic runner-type peanut (Arachis hypogaea L. subsp. hypogaea var. hypogaea) that has enhanced Sclerotinia blight and pod rot tolerance when compared to the cultivar Red River Runner. 'Lariat' (experimental designation ARSOK-R35) is the result of a cross between cultivar Red Rive...
Hot Runner Mold Design of Fan Diverter Parts
NASA Astrophysics Data System (ADS)
Juan, D. J.; Cheng, Y. L.
2017-09-01
In this study, we discuss the case of plastic parts for the production of fan steering gear shaft parts injection molding, and use POM plastic steel to produce plastic parts from traditional cold runners. Because of the parts have a hole, which need side slide. The runner produce more waste after plastic parts injection make the runner waste account for the cost is relatively high, the cost of stock preparation is relatively increased when the product quantity demanded is great. After the crushing treatment of the waste, the backfill will affect the quality, and in the crushing process, the volume generated will make the operator to withstand up to 130 dB of noise. The actual test results show that the production cycle reduce 6.25%, while the production yield increase by about 5% and material costs reduced by 2% . It can be recovered within a year, not to mention the increase of the quality and reduction the noise on the staff of the benefit is impossible to estimate.
The effect of acute exercise on pulsatile release of luteinizing hormone in women runners.
Cumming, D C; Vickovic, M M; Wall, S R; Fluker, M R; Belcastro, A N
1985-11-01
Endurance exercise has been associated with reproductive dysfunction. We have previously suggested that pulsatile release of luteinizing hormone is impaired at rest in normal menstruating runners compared with sedentary women. To determine whether acute exercise had any effect on pulsatile release of luteinizing hormone we investigated serum luteinizing hormone levels in six normal menstruating runners at rest and after 60 minutes of running exercise. Exercise induced an increment in circulating luteinizing hormone levels greater than the change in hematocrit. The luteinizing hormone pulse frequency, calculated as the number of luteinizing hormone pulses per 6 hours, was reduced after exercise compared with values obtained at rest. There was no significant difference in pulse amplitude or area under the 6-hour curve between resting and postexercise situations. These data suggest that acute exercise has an inhibitory effect on luteinizing hormone pulsatile release at the hypothalamic level in eumenorrheic runners that is in addition to the previously described effect of training.
Issues unique to the female runner.
Prather, Heidi; Hunt, Deyvani
2005-08-01
Care and treatment of female runners will improve as further knowledge regarding the unique factors that affect them becomes available. For care and treatment to be their most effective, current and recent information needs to be disseminated among health care providers, coaches, teachers, school administrators, and parents. In young athletes, peer support and education are the most important factors in the success of detection and treatment. Individuals who have the female athlete triad are at significant risk for stress fractures and other injuries. Early detection and multidisciplinary treatment should begin after fractures are detected to reduce or prevent long-term adverse sequelae to bone. In addition, correction of menstrual dysfunction can help to prevent later fertility problems. Addressing the unique biomechanics and core strength of female runners also is essential to rehabilitate athletes past symptom resolution. A thorough understanding of the unique issues for female runners is essential for the prevention of injuries and plays an important role in the promotion of female participation in recreational and competitive running.
Burtscher, Johannes; Furtner, Marco; Sachse, Pierre; Burtscher, Martin
2011-06-01
This study validated a German version of the Sport Motivation Scale (SMS28) and investigated the sex-specific and age-related differences in motivation of competitive mountain runners. Translation and cross-cultural adaptation of the SMS28 was based on translation and back-translation methodology. Acceptable validity of the German version of the SMS28 was indicated by the high correlations (.81 to .98) of scores on the seven subscales for the English and German versions completed by 15 subjects. Motivation analysis was performed with 127 competitive male and female mountain runners. The seven subscales of the German version showed good internal consistency (Cronbach's coefficient alphas .70 to .85). Findings on motivation of competitive mountain runners were a decline across age groups of Intrinsic motivation toward accomplishment for both sexes and an age-related decline of External regulation only for females. These motivational changes might well be associated with the observed diminishing numbers of older participants in mountain running competitions.
Willy, Richard W
2018-01-01
Running-related injuries are common and are associated with a high rate of reoccurrence. Biomechanics and errors in applied training loads are often cited as causes of running-related injuries. Clinicians and runners are beginning to utilize wearable technologies to quantify biomechanics and training loads with the hope of reducing the incidence of running-related injuries. Wearable devices can objectively assess biomechanics and training loads in runners, yet guidelines for their use by clinicians and runners are not currently available. This article outlines several applications for the use of wearable devices in the prevention and rehabilitation of running-related injuries. Applications for monitoring of training loads, running biomechanics, running epidemiology, return to running programs and gait retraining are discussed. Best-practices for choosing and use of wearables are described to provide guidelines for clinicians and runners. Finally, future applications are outlined for this rapidly developing field. Copyright © 2017 Elsevier Ltd. All rights reserved.
Eskofier, Bjoern M; Kraus, Martin; Worobets, Jay T; Stefanyshyn, Darren J; Nigg, Benno M
2012-01-01
The identification of differences between groups is often important in biomechanics. This paper presents group classification tasks using kinetic and kinematic data from a prospective running injury study. Groups composed of gender, of shod/barefoot running and of runners who developed patellofemoral pain syndrome (PFPS) during the study, and asymptotic runners were classified. The features computed from the biomechanical data were deliberately chosen to be generic. Therefore, they were suited for different biomechanical measurements and classification tasks without adaptation to the input signals. Feature ranking was applied to reveal the relevance of each feature to the classification task. Data from 80 runners were analysed for gender and shod/barefoot classification, while 12 runners were investigated in the injury classification task. Gender groups could be differentiated with 84.7%, shod/barefoot running with 98.3%, and PFPS with 100% classification rate. For the latter group, one single variable could be identified that alone allowed discrimination.
Balsalobre-Fernández, Carlos; Santos-Concejero, Jordan; Grivas, Gerasimos V
2016-08-01
Balsalobre-Fernández, C, Santos-Concejero, J, and Grivas, GV. Effects of strength training on running economy in highly trained runners: a systematic review with meta-analysis of controlled trials. J Strength Cond Res 30(8): 2361-2368, 2016-The purpose of this study was to perform a systematic review and meta-analysis of controlled trials to determine the effect of strength training programs on the running economy (RE) of high-level middle- and long-distance runners. Four electronic databases were searched in September 2015 (PubMed, SPORTDiscus, MEDLINE, and CINAHL) for original research articles. After analyzing 699 resultant original articles, studies were included if the following criteria were met: (a) participants were competitive middle- or long-distance runners; (b) participants had a V[Combining Dot Above]O2max >60 ml·kg·min; (c) studies were controlled trials published in peer-reviewed journals; (d) studies analyzed the effects of strength training programs with a duration greater than 4 weeks; and (e) RE was measured before and after the strength training intervention. Five studies met the inclusion criteria, resulting in a total sample size of 93 competitive, high-level middle- and long-distance runners. Four of the 5 included studies used low to moderate training intensities (40-70% one repetition maximum), and all of them used low to moderate training volume (2-4 resistance lower-body exercises plus up to 200 jumps and 5-10 short sprints) 2-3 times per week for 8-12 weeks. The meta-analyzed effect of strength training programs on RE in high-level middle- and long-distance runners showed a large, beneficial effect (standardized mean difference [95% confidence interval] = -1.42 [-2.23 to -0.60]). In conclusion, a strength training program including low to high intensity resistance exercises and plyometric exercises performed 2-3 times per week for 8-12 weeks is an appropriate strategy to improve RE in highly trained middle- and long-distance runners.
Knechtle, Beat; Nikolaidis, Pantelis T; Onywera, Vincent O; Zingg, Matthias A; Rosemann, Thomas; Rüst, Christoph A
2016-01-01
In major marathon races such as the 'World Marathon Majors', female and male East African runners particularly from Ethiopia and Kenya are the fastest. However, whether this trend appears for female and male Ethiopians and Kenyans at recreational level runners (i.e. races at national level) and in shorter road races (e.g. in half-marathon races) has not been studied yet. Thus, the aim of the present study was to examine differences in the performance and the age of female and male runners from East Africa (i.e. Ethiopians and Kenyans) between half- and full marathons. Data from 508,108 athletes (125,894 female and 328,430 male half-marathoners and 10,205 female and 43,489 male marathoners) originating from 126 countries and competing between 1999 and 2014 in all road-based half-marathons and marathons held in one country (Switzerland) were analysed using Chi square (χ(2)) tests, mixed-effects regression analyses and one-way analyses of variance. In half-marathons, 48 women (0.038 %) and 63 men (0.019 %) were from Ethiopia and 80 women (0.063 %) and 134 men (0.040 %) from Kenya. In marathons, three women (0.029 %) and 15 men (0.034 %) were from Ethiopia and two women (0.019 %) and 33 men (0.075 %) from Kenya. There was no statistically significant association between the nationality of East Africans and the format of a race. In both women and men, the fastest race times in half-marathons and marathons were achieved by East African runners (p < 0.001). Ethiopian and Kenyan runners were the youngest in both sexes and formats of race (p < 0.001). In summary, women and men from Ethiopia and Kenya, despite they accounted for <0.1 % in half-marathons and marathons, achieved the fastest race times and were the youngest in both half-marathons and marathons. These findings confirmed in the case of half-marathon the trend previously observed in marathon races for a better performance and a younger age in East African runners from Ethiopia and Kenya.
Hildebrand, Bianca; Kääb, Stefan; Hoster, Eva; Klier, Ina; Martens, Eimo; Hanley, Alan; Hanssen, Henner; Halle, Martin; Nickel, Thomas
2016-01-01
Introduction Physical activity is beneficial for individual health, but endurance sport is associated with the development of arrhythmias like atrial fibrillation. The underlying mechanisms leading to this increased risk are still not fully understood. MicroRNAs are important mediators of proarrhythmogenic remodeling and have potential value as biomarkers in cardiovascular diseases. Therefore, the objective of our study was to determine the value of circulating microRNAs as potential biomarkers for atrial remodeling in marathon runners (miRathon study). Methods 30 marathon runners were recruited into our study and were divided into two age-matched groups depending on the training status: elite (ER, ≥55 km/week, n = 15) and non-elite runners (NER, ≤40 km/week, n = 15). All runners participated in a 10 week training program before the marathon. MiRNA plasma levels were measured at 4 time points: at baseline (V1), after a 10 week training period (V2), immediately after the marathon (V3) and 24h later (V4). Additionally, we obtained clinical data including serum chemistry and echocardiography at each time point. Results MiRNA plasma levels were similar in both groups over time with more pronounced changes in ER. After the marathon miR-30a plasma levels increased significantly in both groups. MiR-1 and miR-133a plasma levels also increased but showed significant changes in ER only. 24h after the marathon plasma levels returned to baseline. MiR-26a decreased significantly after the marathon in elite runners only and miR-29b showed a non-significant decrease over time in both groups. In ER miRNA plasma levels showed a significant correlation with LA diameter, in NER miRNA plasma levels did not correlate with echocardiographic parameters. Conclusion MiRNAs were differentially expressed in the plasma of marathon runners with more pronounced changes in ER. Plasma levels in ER correlate with left atrial diameter suggesting that circulating miRNAs could potentially serve as biomarkers of atrial remodeling in athletes. PMID:26859843
The oil pressure test of the hydraulic impeller blade
NASA Astrophysics Data System (ADS)
Ye, Wen-bo; Jia, Li-tao
2017-12-01
This article introduced the structure of the Kaplan runner in hydropower station and the operating process of the oil pressure test has been described. What’s more, the whole process, including filling oil to the runner hub, the movement of the runner blade, the oil circuit, have been presented in detail.Since the manipulation of the oil circuit which controlled by three Valve groups consisting of six valves was complicated, the author is planning to replace them with 3-position 3-way electromagnetic valves, so we can simplify the operation procedure.The author hopes this article can provide technical reference for the oil pressure test.
DEGATING WORKERS REMOVING SPRUES AND RUNNERS MANUALLY WITH SLEDGEHAMMERS AND ...
DEGATING WORKERS REMOVING SPRUES AND RUNNERS MANUALLY WITH SLEDGEHAMMERS AND POWERED PNEUMATIC SEPARATORS FROM CASTINGS FROM ALL MOLDING MACHINES BEFORE SEPARATING PIECES INTO BINS AND TRANSPORTING THEM TO GRINDING AREAS. - Southern Ductile Casting Company, Shaking, Degating & Sand Systems, 2217 Carolina Avenue, Bessemer, Jefferson County, AL
Improving the accuracy of electronic moisture meters for runner-type peanuts
USDA-ARS?s Scientific Manuscript database
Runner-type peanut kernel moisture content (MC) is measured periodically during curing and post harvest processing with electronic moisture meters for marketing and quality control. MC is predicted for 250 g samples of kernels with a mathematical function from measurements of various physical prope...
Barnes, Kyle R; Janecke, Jessica N
2017-11-21
As a way to train at faster running speeds, add training volume, prevent injury, or rehabilitate after an injury, lower-body positive pressure treadmills (LBPPT) have become increasingly commonplace among athletes. However, there are conflicting evidence and a paucity of data describing the physiological and biomechanical responses to LBPPT running in highly trained or elite caliber runners at the running speeds they habitually train at, which are considerably faster than those of recreational runners. Furthermore, data is lacking regarding female runners' responses to LBPPT running. Therefore, this study was designed to evaluate the physiological and biomechanical responses to LBPPT running in highly trained male and female distance runners. Fifteen highly trained distance runners (seven male; eight female) completed a single running test composed of 4 × 9-min interval series at fixed percentages of body weight ranging from 0 to 30% body weight support (BWS) in 10% increments on LBPPT. The first interval was always conducted at 0% BWS; thereafter, intervals at 10, 20, and 30% BWS were conducted in random order. Each interval consisted of three stages of 3 min each, at velocities of 14.5, 16.1, and 17.7 km·h -1 for men and 12.9, 14.5, and 16.1 km·h -1 for women. Expired gases, ventilation, breathing frequency, heart rate (HR), rating of perceived exertion (RPE), and stride characteristics were measured during each running speed and BWS. Male and female runners had similar physiological and biomechanical responses to running on LBPPT. Increasing BWS increased stride length (p < 0.02) and flight duration (p < 0.01) and decreased stride rate (p < 0.01) and contact time (p < 0.01) in small-large magnitudes. There was a large attenuation of oxygen consumption (VO 2 ) relative to BWS (p < 0.001), while there were trivial-moderate reductions in respiratory exchange ratio, minute ventilation, and respiratory frequency (p > 0.05), and small-large effects on HR and RPE (p < 0.01). There were trivial-small differences in V E , respiratory frequency, HR, and RPE for a given VO 2 across various BWS (p > 0.05). The results indicate the male and female distance runners have similar physiological and biomechanical responses to LBPPT running. Overall, the biomechanical changes during LBPPT running all contributed to less metabolic cost and corresponding physiological changes.
Chin, N W; Chang, F E; Dodds, W G; Kim, M H; Malarkey, W B
1987-10-01
Norepinephrine plays a role in the regulation of luteinizing hormone secretion and may therefore be involved in the etiology of exercise-induced menstrual dysfunction. This study evaluated both intraexercise and postexercise responses of epinephrine, norepinephrine, and dopamine in sedentary women and women runners with normal and abnormal menstruation. Five eumenorrheic nonrunners and five eumenorrheic, four oligomenorrheic, and five amenorrheic runners were evaluated on 2 consecutive days. On day 1, the women cycled on a bicycle ergometer against an increasing work load until exhaustion, and on day 2, the women underwent a submaximal exercise regimen. Serial blood draws were taken at specified time intervals during intraexercise and postexercise periods on both days. The data collected during exercise for all groups showed that epinephrine and norepinephrine had a sixfold to sevenfold rise on day 1 and had a threefold rise on day 2. Dopamine increased twofold during both exercise protocols. On day 1 norepinephrine displayed a significantly higher percentage change from baseline to peak levels for oligomenorrheic and amenorrheic runners than for eumenorrheic runners and sedentary women. This latter finding is consistent with the hypothesis that periodic marked elevations in norepinephrine levels during maximal exercise may interfere with pulsatile luteinizing hormone release and hence may play a role in the occurrence of menstrual dysfunction in women runners.
Hydrodynamic damping and stiffness prediction in Francis turbine runners using CFD
NASA Astrophysics Data System (ADS)
Nennemann, Bernd; Monette, Christine; Chamberland-Lauzon, Joël
2016-11-01
Fluid-structure interaction (FSI) has a major impact on the dynamic response of the structural components of hydroelectric turbines. On mid- to high-head Francis runners, the rotor-stator interaction (RSI) phenomenon has to be considered carefully during the design phase to avoid operational issues on the prototype machine. The RSI dynamic response amplitudes of the runner are driven by three main factors: (1) pressure forcing amplitudes, (2) excitation frequencies in relation to natural frequencies and (3) damping. All three of the above factors are significantly influenced by both mechanical and hydraulic parameters. The prediction of the first two factors has been largely documented in the literature. However, the prediction of hydro-dynamic damping has only recently and only partially been treated. Two mode-based approaches (modal work and coupled single degree of freedom) for the prediction of flow-added dynamic parameters using separate finite element analyses (FEA) in still water and unsteady computational fluid dynamic (CFD) analyses are presented. The modal motion is connected to the time resolved CFD calculation by means of dynamic mesh deformation. This approach has partially been presented in a previous paper applied to a simplified hydrofoil. The present work extends the approach to Francis runners under RSI loading. In particular the travelling wave mode shapes of turbine runners are considered. Reasonable agreement with experimental results is obtained in parts of the operating range.
Isokinetic knee joint evaluation in track and field events.
Deli, Chariklia K; Paschalis, Vassilis; Theodorou, Anastasios A; Nikolaidis, Michalis G; Jamurtas, Athanasios Z; Koutedakis, Yiannis
2011-09-01
The purpose of this study was to evaluate maximal torque of the knee flexors and extensors, flexor/extensor ratios, and maximal torque differences between the 2 lower extremities in young track and field athletes. Forty male track and field athletes 13-17 years old and 20 male nonathletes of the same age participated in the study. Athletes were divided into 4 groups according to their age and event (12 runners and 10 jumpers 13-15 years old, 12 runners and 6 jumpers 16-17 years old) and nonathletes into 2 groups of the same age. Maximal torque evaluation of knee flexors and extensors was performed on an isokinetic dynamometer at 60°·s(-1). At the age of 16-17 years, jumpers exhibited higher strength values at extension than did runners and nonathletes, whereas at the age of 13-15 years, no significant differences were found between events. Younger athletes were weaker than older athletes at flexion. Runners and jumpers were stronger than nonathletes in all relative peak torque parameters. Nonathletes exhibited a higher flexor/extensor ratio compared with runners and jumpers. Strength imbalance in athletes was found between the 2 lower extremities in knee flexors and extensors and also at flexor/extensor ratio of the same extremity. Young track and field athletes exhibit strength imbalances that could reduce their athletic performance, and specific strength training for the weak extremity may be needed.
Time Evolution of Sublingual Microcirculatory Changes in Recreational Marathon Runners
Arstikyte, Justina; Vaitkaitiene, Egle; Vaitkaitis, Dinas
2017-01-01
We aimed to evaluate changes in sublingual microcirculation induced by a marathon race. Thirteen healthy male controls and 13 male marathon runners volunteered for the study. We performed sublingual microcirculation, using a Cytocam-IDF device (Braedius Medical, Huizen, Netherlands), and systemic hemodynamic measurements four times: 24 hours prior to their participation in the Kaunas Marathon (distance: 41.2 km), directly after finishing the marathon, 24 hours after the marathon, and one week after the marathon. The marathon runners exhibited a higher functional capillary density (FCD) and total vascular density of small vessels at the first visit compared with the controls. Overall, we did not find any changes in sublingual microcirculation of the marathon runners at any of the other visits. However, in a subgroup of marathon runners with a decreased FCD compared to the subgroup with increased FCD, the subgroup with decreased FCD had shorter running time (190.37 ± 30.2 versus 221.80 ± 23.4 min, p = 0.045), ingested less fluids (907 ± 615 versus 1950 ± 488 mL, p = 0.007) during the race, and lost much more weight (−2.4 ± 1.3 versus −1.0 ± 0.8 kg, p = 0.041). Recreational marathon running is not associated with an alteration of sublingual microcirculation. However, faster running and dehydration may be crucial for further impairing microcirculation. PMID:28828386
Laye, M J; Nielsen, M B; Hansen, L S; Knudsen, T; Pedersen, B K
2015-01-01
High levels of cardiovascular fitness (CRF) and physical activity (PA) are associated with decreased mortality and risk to develop metabolic diseases. The independent contributions of CRF and PA to metabolic disease risk factors are unknown. We tested the hypothesis that runners who run consistently >50 km/wk and/or >2 marathons/yr for the last 5 years have superior metabolic fitness compared to matched sedentary subjects (CRF, age, gender, and BMI). Case-control recruitment of 31 pairs of runner-sedentary subjects identified 10 matched pairs with similar VO2max (mL/min/kg) (similar-VO2max). The similar-VO2max group was compared with a group of age, gender, and BMI matched pairs who had the largest difference in VO2max (different-VO2max). Primary outcomes that defined metabolic fitness including insulin response to an oral glucose tolerance test, fasting lipids, and fasting insulin were superior in runners versus sedentary controls despite similar VO2max. Furthermore, performance (velocity at VO2max, running economy), improved exercise metabolism (lactate threshold), and skeletal muscle levels of mitochondrial proteins were superior in runners versus sedentary controls with similar VO2max. In conclusion subjects with a high amount of PA have more positive metabolic health parameters independent of CRF. PA is thus a good marker against metabolic diseases.
Laye, M. J.; Nielsen, M. B.; Hansen, L. S.; Knudsen, T.; Pedersen, B. K.
2015-01-01
High levels of cardiovascular fitness (CRF) and physical activity (PA) are associated with decreased mortality and risk to develop metabolic diseases. The independent contributions of CRF and PA to metabolic disease risk factors are unknown. We tested the hypothesis that runners who run consistently >50 km/wk and/or >2 marathons/yr for the last 5 years have superior metabolic fitness compared to matched sedentary subjects (CRF, age, gender, and BMI). Case-control recruitment of 31 pairs of runner-sedentary subjects identified 10 matched pairs with similar VO2max (mL/min/kg) (similar-VO2max). The similar-VO2max group was compared with a group of age, gender, and BMI matched pairs who had the largest difference in VO2max (different-VO2max). Primary outcomes that defined metabolic fitness including insulin response to an oral glucose tolerance test, fasting lipids, and fasting insulin were superior in runners versus sedentary controls despite similar VO2max. Furthermore, performance (velocity at VO2max, running economy), improved exercise metabolism (lactate threshold), and skeletal muscle levels of mitochondrial proteins were superior in runners versus sedentary controls with similar VO2max. In conclusion subjects with a high amount of PA have more positive metabolic health parameters independent of CRF. PA is thus a good marker against metabolic diseases. PMID:25821340
Distinct hip and rearfoot kinematics in female runners with a history of tibial stress fracture.
Milner, Clare E; Hamill, Joseph; Davis, Irene S
2010-02-01
Cross-sectional controlled laboratory study. To investigate the kinematics of the hip, knee, and rearfoot in the frontal and transverse planes in female distance runners with a history of tibial stress fracture. Tibial stress fractures are a common overuse injury in runners, accounting for up to half of all stress fractures. Abnormal kinematics of the lower extremity may contribute to abnormal musculoskeletal load distributions, leading to an increased risk of stress fractures. Thirty female runners with a history of tibial stress fracture were compared to 30 age-matched and weekly-running-distance-matched control subjects with no previous lower extremity bony injuries. Kinematic and kinetic data were collected using a motion capture system and a force platform, respectively, as subjects ran in the laboratory. Selected variables of interest were compared between the groups using a multivariate analysis of variance (MANOVA). Peak hip adduction and peak rearfoot eversion angles were greater in the stress fracture group compared to the control group. Peak knee adduction and knee internal rotation angles and all joint angles at impact peak were similar between the groups. Runners with a previous tibial stress fracture exhibited greater peak hip adduction and rearfoot eversion angles during the stance phase of running compared to healthy controls. A consequence of these mechanics may be altered load distribution within the lower extremity, predisposing individuals to stress fracture.
Louw, Maryke; Deary, Clare
2014-02-01
The aim of this literature review was to identify the biomechanical variables involved in the aetiology of iliotibial band syndrome (ITBS) in distance runners. An electronic search was conducted using the terms "iliotibial band" and "iliotibial tract". The results showed that runners with a history of ITBS appear to display decreased rear foot eversion, tibial internal rotation and hip adduction angles at heel strike while having greater maximum internal rotation angles at the knee and decreased total abduction and adduction range of motion at the hip during stance phase. They further appear to experience greater invertor moments at their feet, decreased abduction and flexion velocities at their hips and to reach maximum hip flexion angles earlier than healthy controls. Maximum normalised braking forces seem to be decreased in these athletes. The literature is inconclusive with regards to muscle strength deficits in runners with a history of ITBS. Prospective research suggested that greater internal rotation at the knee joint and increased adduction angles of the hip may play a role in the aetiology of ITBS and that the strain rate in the iliotibial bands of these runners may be increased compared to healthy controls. A clear biomechanical cause for ITBS could not be devised due to the lack of prospective research. Copyright © 2013 Elsevier Ltd. All rights reserved.
The NLstart2run study: Incidence and risk factors of running-related injuries in novice runners.
Kluitenberg, B; van Middelkoop, M; Smits, D W; Verhagen, E; Hartgens, F; Diercks, R; van der Worp, H
2015-10-01
Running is a popular form of physical activity, despite of the high incidence of running-related injuries (RRIs). Because of methodological issues, the etiology of RRIs remains unclear. Therefore, the purposes of the study were to assess the incidence of RRIs and to identify risk factors for RRIs in a large group of novice runners. In total, 1696 runners of a 6-week supervised "Start to Run" program were included in the NLstart2run study. All participants were aged between 18 and 65, completed a baseline questionnaire that covered potential risk factors, and completed at least one running diary. RRIs were registered during the program with a weekly running log. An RRI was defined as a musculo-skeletal complaint of the lower extremity or back attributed to running and hampering running ability for three consecutive training sessions. During the running program, 10.9% of the runners sustained an RRI. The multivariable Cox regression analysis showed that a higher age, higher BMI, previous musculo-skeletal complaints not attributed to sports and no previous running experience were related to RRI. These findings indicate that many novice runners participating in a short-term running program suffer from RRIs. Therefore, the identified risk factors should be considered for screening and prevention purposes. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
What Research Tells the Coach About Distance Running.
ERIC Educational Resources Information Center
Costill, David L.
This booklet is designed to make available research findins concerning distance running with interpretations, for practical applications, and to point out areas of needed research. Chapter 1, "Describing the Distance Runner," considers the following aspects in relation to the distance runner: a) anatomical characteristics, b) aging, c) strength…