Sample records for vt cycle length

  1. Triggers of sustained monomorphic ventricular tachycardia differ among patients with varying etiologies of left ventricular dysfunction.

    PubMed

    Rosman, Jonathan; Hanon, Sam; Shapiro, Michael; Evans, Steven J; Schweitzer, Paul

    2006-04-01

    The mechanisms underlying the initiation of sustained ventricular tachycardia (VT) have not been fully elucidated. The extent to which reentry, abnormal automaticity, and triggered activity play a role in VT differs depending on the etiology of left ventricular dysfunction. By analyzing electrograms from implantable cardioverter defibrillator (ICD), we sought to determine whether there were differences in VT initiation patterns between patients with ischemic and nonischemic cardiomyopathy. We analyzed ICD electrograms in patients with ejection fractions < 40% who had sustained VT over a 27-month period. The trigger for VT onset was classified as a ventricular premature beat (VPB), supraventricular tachycardia, or of "sudden onset." The baseline cycle length, VT cycle length, coupling interval, and prematurity ratio were recorded for each event. The prematurity ratio was calculated as the coupling interval of the VT initiator divided by the baseline cycle length. Sixty-three VT events in 14 patients met the inclusion criteria. A VPB initiated the VT in 58 episodes (92%), 1 episode (2%) was initiated by a supraventricular tachycardia, and 4 episodes (6%) were sudden onset. The prematurity ratio was significantly higher (P < 0.05) in patients with ischemic cardiomyopathy (0.751 +/- 0.068) as compared to patients with nonischemic cardiomyopathy (0.604 +/- 0.139). VPBs initiated most sustained VT episodes. A significantly higher prematurity ratio was observed in the ischemic heart disease group. This may represent different mechanisms of VT initiation in patients with ischemic versus nonischemic heart disease.

  2. Differences in Pedaling Technique in Cycling: A Cluster Analysis.

    PubMed

    Lanferdini, Fábio J; Bini, Rodrigo R; Figueiredo, Pedro; Diefenthaeler, Fernando; Mota, Carlos B; Arndt, Anton; Vaz, Marco A

    2016-10-01

    To employ cluster analysis to assess if cyclists would opt for different strategies in terms of neuromuscular patterns when pedaling at the power output of their second ventilatory threshold (PO VT2 ) compared with cycling at their maximal power output (PO MAX ). Twenty athletes performed an incremental cycling test to determine their power output (PO MAX and PO VT2 ; first session), and pedal forces, muscle activation, muscle-tendon unit length, and vastus lateralis architecture (fascicle length, pennation angle, and muscle thickness) were recorded (second session) in PO MAX and PO VT2 . Athletes were assigned to 2 clusters based on the behavior of outcome variables at PO VT2 and PO MAX using cluster analysis. Clusters 1 (n = 14) and 2 (n = 6) showed similar power output and oxygen uptake. Cluster 1 presented larger increases in pedal force and knee power than cluster 2, without differences for the index of effectiveness. Cluster 1 presented less variation in knee angle, muscle-tendon unit length, pennation angle, and tendon length than cluster 2. However, clusters 1 and 2 showed similar muscle thickness, fascicle length, and muscle activation. When cycling at PO VT2 vs PO MAX , cyclists could opt for keeping a constant knee power and pedal-force production, associated with an increase in tendon excursion and a constant fascicle length. Increases in power output lead to greater variations in knee angle, muscle-tendon unit length, tendon length, and pennation angle of vastus lateralis for a similar knee-extensor activation and smaller pedal-force changes in cyclists from cluster 2 than in cluster 1.

  3. Mechanism-specific effects of adenosine on ventricular tachycardia.

    PubMed

    Lerman, Bruce B; Ip, James E; Shah, Bindi K; Thomas, George; Liu, Christopher F; Ciaccio, Edward J; Wit, Andrew L; Cheung, Jim W; Markowitz, Steven M

    2014-12-01

    There is no universally accepted method by which to diagnose clinical ventricular tachycardia (VT) due to cAMP-mediated triggered activity. Based on cellular and clinical data, adenosine termination of VT is thought to be consistent with a diagnosis of triggered activity. However, a major gap in evidence mitigates the validity of this proposal, namely, defining the specificity of adenosine response in well-delineated reentrant VT circuits. To this end, we systematically studied the effects of adenosine in a model of canine reentrant VT and in human reentrant VT, confirmed by 3-dimensional, pace- and substrate mapping. Adenosine (12 mg [IQR 12-24]) failed to terminate VT in 31 of 31 patients with reentrant VT due to structural heart disease, and had no effect on VT cycle length (age, 67 years [IQR 53-74]); ejection fraction, 35% [IQR 20-55]). In contrast, adenosine terminated VT in 45 of 50 (90%) patients with sustained focal right or left outflow tract tachycardia. The sensitivity of adenosine for identifying VT due to triggered activity was 90% (95% CI, 0.78-0.97) and its specificity was 100% (95% CI, 0.89-1.0). Additionally, reentrant circuits were mapped in the epicardial border zone of 4-day-old infarcts in mongrel dogs. Adenosine (300-400 μg/kg) did not terminate sustained VT or have any effect on VT cycle length. These data support the concept that adenosine's effects on ventricular myocardium are mechanism specific, such that termination of VT in response to adenosine is diagnostic of cAMP-mediated triggered activity. © 2014 Wiley Periodicals, Inc.

  4. Scar extent as a predictive factor of ventricular tachycardia cycle length after myocardial infarction: implications for implantable cardioverter-defibrillator programming optimization.

    PubMed

    Alexandre, Joachim; Saloux, Eric; Lebon, Alain; Dugué, Audrey Emmanuelle; Lemaitre, Adrien; Roule, Vincent; Labombarda, Fabien; Champ-Rigot, Laure; Gomes, Sophie; Pellissier, Arnaud; Scanu, Patrice; Milliez, Paul

    2014-02-01

    After an old myocardial infarction (MI), patients are at risk for reentrant ventricular tachycardia (VT) due to scar tissue that can be accurately identified by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR). Although the ability of LGE-CMR to predict sustained VT in implantable cardioverter-defibrillator (ICD) recipients has been well established, its use to predict monomorphic VT (sustained or not) cycle length (CL) and so, optimize ICD programming has never been investigated. We included retrospectively 49 consecutive patients with an old MI who had undergone LGE-CMR before ICD implantation over a 4-year period (2006-09). Patients with amiodarone used were excluded. Scar extent was assessed by measuring scar mass, percent scar, and transmural scar extent. The endpoint was the occurrence of monomorphic VT, requiring an ICD therapy or not. The endpoint occurred in 26 patients. The median follow-up duration was 31 months. Scar extent parameters were significantly correlated with the study endpoint. With univariate regression analysis, the scar mass had the highest correlation with the VT CL (R = 0.671, P = 0.0002). Receiver-operating characteristic curve showed that scar mass can predict VT CL (area under the curve = 0.977, P < 0.0001). For a cut-off value of scar mass at 17.6 g, there is 100% specificity and 94.4% sensitivity. In this observational and retrospective study, scar mass studied by LGE-CMR was specific and sensitive to predict VT CL and so could be a promising option to improve ICD post-implantation programming and decrease appropriate and inappropriate shocks. These conclusions must now be confirmed in a large and prospective study.

  5. Clinical and Electrocardiographic Characteristics of Electrical Storms Due to Monomorphic Ventricular Tachycardia Refractory to Intravenous Amiodarone.

    PubMed

    Murata, Hiroshige; Miyauchi, Yasushi; Hayashi, Meiso; Iwasaki, Yu-Ki; Yodogawa, Kenji; Ueno, Akira; Hayashi, Hiroshi; Tsuboi, Ippei; Uetake, Shunsuke; Takahashi, Kenta; Yamamoto, Teppei; Maruyama, Mitsunori; Akutsu, Koichi; Yamamoto, Takeshi; Kobayashi, Yoshinori; Tanaka, Keiji; Atarashi, Hirotsugu; Katoh, Takao; Shimizu, Wataru

    2015-01-01

    Few reports are available on the characteristics of electrical storms of ventricular tachycardia (VT storm) refractory to intravenous (IV) amiodarone. IV-amiodarone was administered to 60 patients with ventricular tachyarrhythmia between 2007 and 2012. VT storms, defined as 3 or more episodes of VT within 24 h, occurred in 30 patients (68±12 years, 7 female), with 12 having ischemic and 18 non-ischemic heart disease. We compared the clinical and electrocardiographic characteristics of the patients with VT storms suppressed by IV-amiodarone (Effective group) to those of patients not affected by the treatment (Refractory group). IV-amiodarone could not control recurrence of VT in 9 patients (30%). The Refractory group comprised 5 patients with acute myocardial infarctions. Although there was no difference in the VT cycle length, the QRS duration of both the VT and premature ventricular contractions (PVCs) followed by VT was narrower in the Refractory group than in the Effective group (140±30 vs. 178±25 ms, P<0.01; 121±14 vs. 179±22 ms, P<0.01). In the Refractory group, additional administration of IV-mexiletine and/or Purkinje potential-guided catheter ablation was effective. IV-amiodarone-refractory VT exhibited a relatively narrow QRS tachycardia. The narrow triggering PVCs, suggesting a Purkinje fiber origin, may be treated by additional IV-mexiletine and endocardial catheter ablation.

  6. A Novel Low-Energy Electrotherapy That Terminates Ventricular Tachycardia With Lower Energy than a Biphasic Shock When Anti-Tachycardia Pacing Fails

    PubMed Central

    Janardhan, Ajit H.; Li, Wenwen; Fedorov, Vadim V.; Yeung, Michael; Wallendorf, Michael J.; Schuessler, Richard B.; Efimov, Igor R.

    2015-01-01

    Objectives To develop a low-energy electrotherapy that terminates ventricular tachycardia (VT) when anti-tachycardia pacing (ATP) fails. Background High-energy ICD shocks are associated with device failure, significant morbidity and increased mortality. A low-energy alternative to ICD shocks is desirable. Methods Myocardial infarction (MI) was created in 25 dogs. Sustained, monomorphic VT was induced by programmed stimulation. Defibrillation electrodes were placed in the RV apex, and coronary sinus (CS) and LV epicardium (LVP). If ATP failed to terminate sustained VT, the defibrillation thresholds (DFTs) of standard versus experimental electrotherapies were measured. Results Sustained VT ranged from 276–438 bpm (mean 339 bpm). The RV-CS shock vector had lower impedance than RV-LVP (54.4±18.1 Ω versus 109.8±16.9, Ω p<0.001). A single shock required between 0.3±0.2 J to 5.9±2.5 J (mean 2.64±3.22 J; p=0.008) to terminate VT, and varied depending upon the phase of the VT cycle at which it was delivered. In contrast, multiple shocks delivered within 1 VT cycle length were not phase-dependent and achieved lower DFT compared to a single shock (0.13±0.09 J for 3 shocks, 0.08±0.04 J for 5 shocks, 0.09±0.07 J for 7 shocks; p<0.001). Finally, a multi-stage electrotherapy (MSE) achieved significantly lower DFT compared to a single biphasic shock (0.03±0.05 J versus 2.37±1.20 J, respectively, p<0.001). At a peak shock amplitude of 20 V, MSE achieved 91.3% of terminations versus 10.5% for a biphasic shock (p<0.001). Conclusions MSE achieved a major reduction in DFT compared to a single biphasic shock for ATP-refractory monomorphic VT, and represents a novel electrotherapy to reduce high-energy ICD shocks. PMID:23141483

  7. Differentiation of ventricular and supraventricular tachycardias based on the analysis of the first postpacing interval after sequential anti-tachycardia pacing in implantable cardioverter-defibrillator patients.

    PubMed

    Arenal, Angel; Ortiz, Mercedes; Peinado, Rafael; Merino, Jose L; Quesada, Aurelio; Atienza, Felipe; Alberola, Arcadio García; Ormaetxe, Jose; Castellanos, Eduardo; Rodriguez, Juan C; Pérez, Nicasio; García, Javier; Boluda, Luis; del Prado, Mario; Artés, Antonio

    2007-03-01

    Current discrimination algorithms do not completely avoid inappropriate tachycardia detection. This study analyzes the discrimination capability of the changes of the first postpacing interval (FPPI) after successive bursts of anti-tachycardia pacing (ATP) trains in implantable cardioverter-defibrillator (ICD)-recorded tachycardias. We included 50 ICD patients in this prospective study. We hypothesized that the FPPI variability (FPPIV) when comparing bursts with different numbers of beats would be shorter in ventricular tachycardias (VTs) compared with supraventricular tachycardias (SVTs). The ATP (5-10 pulses, 91% of tachycardia cycle length) was programmed for tachycardias >240 ms. Anti-tachycardia pacing was delivered during 37 sinus tachycardias (STs) in an exercise test, 96 induced VTs in an electrophysiological study, and 198 spontaneous episodes (144 VTs and 54 SVTs). The FPPI remained stable after all ATP bursts in VT but changed continuously in SVT; when comparing bursts of 5 and 10 pulses, the FPPIV was shorter in VT (34 +/- 65 vs.138 +/- 69, P<.0001, in all T and 12 +/- 20 vs. 138 +/- 69, P<.0001, in T>or=320 ms) than in SVT. In T>or=320 ms an FPPIV

  8. Identification of verotoxin type 2 variant B subunit genes in Escherichia coli by the polymerase chain reaction and restriction fragment length polymorphism analysis.

    PubMed Central

    Tyler, S D; Johnson, W M; Lior, H; Wang, G; Rozee, K R

    1991-01-01

    A set of synthetic oligonucleotide primers was designed for use in a polymerase chain reaction protocol to specifically detect the B subunit genes in vtx2ha and vtx2hb, which code for the production of the VT2 (Shiga-like toxin II) variant cytotoxins VT2v-a and VT2v-b, respectively. An additional set of primers amplified a fragment common to the B subunits of the VT2 and the VT2 variant genes. Subsequent restriction endonuclease digestion of this amplicon permitted prediction of specific VT2 and variant genotypes on the basis of predetermined restriction fragment length polymorphisms. Genotypes of 21 VT2-producing strains of Escherichia coli were determined using this polymerase chain reaction-restriction fragment length polymorphism procedure. Four strains contained B subunit target sequences only for VT2 genes, 9 strains contained sequences only for VT2v-a genes, and 3 strains contained sequences only for VT2v-b. For genes in combination, one strain contained B subunit genes for both VT2 and VT2v-a and two strains contained B subunit genes for VT2 and VT2v-b. Two strains of E. coli O91:H21 contained both VT2v-a and VT2v-b B subunit genes. The VT2 reference strain of E. coli, E32511, was found to contain the targeted sequences from both VT2 and VT2v-a genes, whereas the recombinant E. coli, pEB1, possessed only that of the VT2 gene. The specific activities of extracellular VT2 determined in HeLa cells ranged from 0.3 to 41.7 TCD50 per microgram of protein in strains carrying the VT2 gene target and from 0 to 50.0 TCD50 per microgram of protein in strains carrying only the VT2 variant target (TCD50 is the tissue culture dose by which 50% of the cells were affected), suggesting that phenotypic expression does not correlate with genotype. Images PMID:1679436

  9. A novel low-energy electrotherapy that terminates ventricular tachycardia with lower energy than a biphasic shock when antitachycardia pacing fails.

    PubMed

    Janardhan, Ajit H; Li, Wenwen; Fedorov, Vadim V; Yeung, Michael; Wallendorf, Michael J; Schuessler, Richard B; Efimov, Igor R

    2012-12-11

    The authors sought to develop a low-energy electrotherapy that terminates ventricular tachycardia (VT) when antitachycardia pacing (ATP) fails. High-energy implantable cardioverter-defibrillator (ICD) shocks are associated with device failure, significant morbidity, and increased mortality. A low-energy alternative to ICD shocks is desirable. Myocardial infarction was created in 25 dogs. Sustained, monomorphic VT was induced by programmed stimulation. Defibrillation electrodes were placed in the right ventricular apex, and coronary sinus and left ventricular epicardium. If ATP failed to terminate sustained VT, the defibrillation thresholds (DFTs) of standard versus experimental electrotherapies were measured. Sustained VT ranged from 276 to 438 beats/min (mean 339 beats/min). The right ventricular-coronary sinus shock vector had lower impedance than the right ventricular-left ventricular patch (54.4 ± 18.1 Ω versus 109.8 ± 16.9 Ω; p < 0.001). A single shock required between 0.3 ± 0.2 J to 5.9 ± 2.5 J (mean 2.64 ± 3.22 J; p = 0.008) to terminate VT, and varied depending upon the phase of the VT cycle in which it was delivered. By contrast, multiple shocks delivered within 1 VT cycle length were not phase dependent and achieved lower DFT compared with a single shock (0.13 ± 0.09 J for 3 shocks, 0.08 ± 0.04 J for 5 shocks, and 0.09 ± 0.07 J for 7 shocks; p < 0.001). Finally, a multistage electrotherapy (MSE) achieved significantly lower DFT compared with a single biphasic shock (0.03 ± 0.05 J versus 2.37 ± 1.20 J; respectively, p < 0.001). At a peak shock amplitude of 20 V, MSE achieved 91.3% of terminations versus 10.5% for a biphasic shock (p < 0.001). MSE achieved a major reduction in DFT compared with a single biphasic shock for ATP-refractory monomorphic VT, and represents a novel electrotherapy to reduce high-energy ICD shocks. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  10. Re-entry using anatomically determined isthmuses: a curable ventricular tachycardia in repaired congenital heart disease.

    PubMed

    Kapel, Gijsbert F L; Reichlin, Tobias; Wijnmaalen, Adrianus P; Piers, Sebastiaan R D; Holman, Eduard R; Tedrow, Usha B; Schalij, Martin J; Stevenson, William G; Zeppenfeld, Katja

    2015-02-01

    Ventricular tachycardia (VT) is an important cause of late morbidity and mortality in repaired congenital heart disease. The substrate often includes anatomic isthmuses that can be transected by radiofrequency catheter ablation similar to isthmus block for atrial flutter. This study evaluates the long-term efficacy of isthmus block for treatment of re-entry VT in adults with repaired congenital heart disease. Thirty-four patients (49±13 years; 74% male) with repaired congenital heart disease who underwent radiofrequency catheter ablation of VT in 2 centers were included. Twenty-two (65%) had a preserved left and right ventricular function. Patients were inducible for 1 (interquartile range, 1-2) VT, median cycle length: 295 ms (interquartile range, 242-346). Ablation aimed to transect anatomic isthmuses containing VT re-entry circuit isthmuses. Procedural success was defined as noninducibility of any VT and transection of the anatomic isthmus and was achieved in 25 (74%) patients. During long-term follow-up (46±29 months), all patients with procedural success (18/25 with internal cardiac defibrillators) were free of VT recurrence but 7 of 18 experienced internal cardiac defibrillator-related complications. One patient with procedural success and depressed cardiac function received an internal cardiac defibrillator shock for ventricular fibrillation. None of the 18 patients (12/18 with internal cardiac defibrillators) with complete success and preserved cardiac function experienced any ventricular arrhythmia. In contrast, VT recurred in 4 of 9 patients without procedural success. Four patients died from nonarrhythmic causes. In patients with repaired congenital heart disease with preserved ventricular function and isthmus-dependent re-entry, VT isthmus ablation can be curative. © 2014 American Heart Association, Inc.

  11. Long-Term Outcomes of Catheter Ablation of Electrical Storm in Nonischemic Dilated Cardiomyopathy Compared With Ischemic Cardiomyopathy.

    PubMed

    Muser, Daniele; Liang, Jackson J; Pathak, Rajeev K; Magnani, Silvia; Castro, Simon A; Hayashi, Tatsuya; Garcia, Fermin C; Supple, Gregory E; Riley, Michael P; Lin, David; Dixit, Sanjay; Zado, Erica S; Frankel, David S; Callans, David J; Marchlinski, Francis E; Santangeli, Pasquale

    2017-07-01

    The goal of this study was to determine the long-term outcomes of catheter ablation (CA) of electrical storm in patients with nonischemic dilated cardiomyopathy (NIDCM) compared with patients with ischemic cardiomyopathy (ICM). CA of ventricular tachycardia (VT) electrical storm has been shown to improve VT-free survival in patients with ICM. Data on the outcomes of CA of electrical storm in patients with NIDCM are insufficient. The study included 267 consecutive patients with NIDCM (n = 71; ejection fraction 32 ± 14%) and ICM (n = 196; ejection fraction 28 ± 12%). Endo-epicardial CA was performed in 59 (22%) patients. CA was guided by activation and entrainment mapping for tolerated VT and pacemapping/targeting of abnormal substrate for unmappable VT. After a median follow-up of 45 (25th to 75th percentile: 9 to 71) months and 1 (25th to 75th percentile: 1 to 8) procedures, 76 (29%) patients died, 25 (9%) underwent heart transplantation, 87 (33%) experienced VT recurrence, and 13 (5%) had recurrence of electrical storm. Overall VT-free survival was 54% at 60 months (48% in NIDCM and 54% in ICM; p = 0.128). Patients with VT recurrence experienced a median of 2 (1 to 10) VT episodes in the 5 (1 to 14) months after the procedure. Death/transplantation-free survival was 62% at 60 months (53% in NIDCM and 64% in ICM; p = 0.067). Persistent inducibility of any VT with cycle length ≥250 ms at programmed stimulation at the end of the procedure was the only independent predictor of VT recurrence. Low ejection fraction, New York Heart Association functional class, and VT recurrence over follow-up independently predicted death/transplantation. CA of electrical storm was similarly effective in patients with NIDCM compared with patients with ICM, with elimination of electrical storm in 95% of cases and achievement of complete VT control at long-term follow-up in most patients. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. Ventricular Arrhythmias in the North American Multidisciplinary Study of ARVC

    PubMed Central

    Link, Mark S.; Laidlaw, Douglas; Polonsky, Bronislava; Zareba, Wojciech; McNitt, Scott; Gear, Kathleen; Marcus, Frank; Mark Estes, NA

    2015-01-01

    BACKGROUND Arrhythmogenic right ventricular cardiomyopathy (ARVC) is associated with sudden cardiac death. However, the selection of patients for implanted cardioverter-defibrillators (ICDs), as well as programming of the ICD, is unclear. OBJECTIVES The objective of this study was to identify predictors, characteristics, and treatment of ventricular arrhythmias in patients with ARVC. METHODS The Multidisciplinary Study of Right Ventricular Cardiomyopathy established the North American ARVC Registry and enrolled patients with a diagnosis of ARVC. Patients were followed prospectively. RESULTS Of 137 patients enrolled, 108 received ICDs. Forty-eight patients had 502 sustained episodes of ventricular arrhythmias, including 489 that were monomorphic and 13 that were polymorphic. In the patients with ICDs, independent predictors of ventricular arrhythmias in follow-up included spontaneous sustained ventricular arrhythmias before ICD implantation and T-wave inversions inferiorly. The only independent predictor for life-threatening arrhythmias, defined as sustained ventricular tachycardia (VT) ≥240 beats/min or ventricular fibrillation, was a younger age at enrollment. Anti-tachycardia pacing (ATP), independent of the cycle length of the VT, was successful in terminating 92% of VT episodes. CONCLUSIONS In the North American ARVC Registry, the majority of ventricular arrhythmias in follow-up are monomorphic. Risk factors for ventricular arrhythmias were spontaneous ventricular arrhythmias before enrollment and a younger age at ICD implantation. ATP is highly successful in terminating VT, and all ICDs should be programmed for ATP, even for rapid VT. PMID:25011714

  13. Respiratory Pattern and Tidal Volumes Differ for Pressure Support and Volume-assured Pressure Support in Amyotrophic Lateral Sclerosis.

    PubMed

    Nicholson, Trevor T; Smith, Sean B; Siddique, Teepu; Sufit, Robert; Ajroud-Driss, Senda; Coleman, John M; Wolfe, Lisa F

    2017-07-01

    Amyotrophic lateral sclerosis (ALS) is a progressive neuromuscular disease resulting in respiratory failure and death. Use of noninvasive ventilation (NIV) improves survival. However, use of volume-assured pressure support (VAPS) has not been extensively studied in ALS. To explore the clinical usefulness of a detailed evaluation of device-recorded NIV data in the management of chronic respiratory failure in ALS, and to determine whether there are differences in efficacy between patients using VAPS or PS. We performed a retrospective chart review of 271 patients with ALS using either PS or VAPS, along with an evaluation of device-recorded data to explore differences in attainment of goal tidal volumes (Vt) and ratio of respiratory rate to tidal volume (f/Vt), in addition to triggering and cycling ability. Two hundred and fifteen patients were using PS, while 56 were using VAPS. There were no significant differences in demographic data, symptoms, pulmonary function, or patient compliance. Compared with VAPS, achieved Vt was significantly lower for PS while f/Vt was significantly higher. Percent spontaneous triggering was relatively preserved in both cohorts, whereas percent spontaneous cycling was considerably decreased in both. Furthermore, there was no association found between spontaneous triggering or cycling, and pulmonary function, indicating the presence of low spontaneous breath cycling or triggering ability is difficult to predict. Examination of device data for exhaled tidal volumes and f/Vt may be of use in evaluating efficacy of NIV in ALS. VAPS provides more reliable goal Vt than does PS, and is associated with decreased f/Vt. Spontaneous cycling is decreased in ALS despite preservation of triggering ability. Although a set backup rate may address decreased triggering, perhaps more importantly, setting a sufficient fixed inspiratory time would address the issue of decreased cycling.

  14. Value of right ventricular mapping in patients with postinfarction ventricular tachycardia.

    PubMed

    Yokokawa, Miki; Good, Eric; Crawford, Thomas; Chugh, Aman; Pelosi, Frank; Latchamsetty, Rakesh; Oral, Hakan; Morady, Fred; Bogun, Frank

    2012-06-01

    Postinfarction ventricular tachycardia (VT) typically involves the left ventricular endocardium. Right ventricular involvement in the arrhythmogenic substrate of postinfarction VT is considered unusual. To assess the role of right ventricular mapping and ablation in patients with prior septal myocardial infarction. From among 37 consecutive patients with recurrent postinfarction VT, 18 patients with evidence of left ventricular septal involvement of myocardial infarction were identified; these patients were the subjects of this report. In these 18 patients, 166 VTs (cycle length 372 ± 117 ms) were induced. Right ventricular voltage mapping was performed in all 18 patients with left ventricular septal myocardial infarction. Right ventricular voltage mapping showed areas of low voltage in 11 patients; pace mapping from these areas revealed matching pace maps for 17 VTs, and radiofrequency ablation from the right ventricular endocardium but not the left ventricular endocardium eliminated 14 of 17 VTs. VTs with critical components in the right ventricle had a left bundle branch block morphology that had similar characteristics as left bundle branch block VTs with critical areas involving the left ventricular septum. Patients with right ventricular VT breakthrough sites had a lower ejection fraction than did patients without VT breaking out on the right ventricular septum (18% ± 5% vs 33% ± 15%; P = .01). Right ventricular mapping and ablation may be necessary in order to eliminate all inducible VTs in patients with postinfarction VT. More than half the patients with septal myocardial infarction have right ventricular septal areas that are critical for postinfarction VT and that cannot be eliminated by left ventricular ablation alone. Copyright © 2012 Heart Rhythm Society. All rights reserved.

  15. Efficacy of implantable cardioverter defibrillators in young patients with catecholaminergic polymorphic ventricular tachycardia: success depends on substrate.

    PubMed

    Miyake, Christina Y; Webster, Gregory; Czosek, Richard J; Kantoch, Michal J; Dubin, Anne M; Avasarala, Kishor; Atallah, Joseph

    2013-06-01

    The effectiveness of implantable cardioverter-defibrillator (ICD) therapy for the management of catecholaminergic polymorphic ventricular tachycardia (VT) in young patients is not known. ICD discharges are not always effective and inappropriate discharges are common, both resulting in morbidity and mortality. This is a multicenter, retrospective review of young patients with catecholaminergic polymorphic VT and ICDs from 5 centers. ICD discharges were evaluated to determine arrhythmia mechanism, appropriateness, efficacy of therapy, and complications. A total of 24 patients were included. Median (interquartile range) ages at onset of catecholaminergic polymorphic VT symptoms and ICD implant were 10.6 (5.0-13.8) years and 13.7 (10.7-16.3) years, respectively. Fourteen patients received 140 shocks. Ten patients (42%) experienced 75 appropriate shocks and 11 patients (46%) received 65 inappropriate shocks. On actuarial analysis, freedom from appropriate shock at 1 year after ICD implant was 75%. Of appropriate shocks, only 43 (57%) demonstrated successful primary termination. All successful appropriate ICD discharges were for ventricular fibrillation. No episodes of polymorphic VT or bidirectional VT demonstrated successful primary termination. The adjusted mean (95% confidence interval) cycle length of successful discharges was significantly shorter than unsuccessful discharges (168 [152-184] ms versus 245 [229-262] ms; adjusted P=0.002). Electrical storm occurred in 29% (4/14) and induction of more malignant ventricular arrhythmias in 36% (5/14). There were no deaths. ICD efficacy in catecholaminergic polymorphic VT depends on arrhythmia mechanism. Episodes of ventricular fibrillation were uniformly successfully treated, whereas polymorphic and bidirectional VT did not demonstrate successful primary termination. Inappropriate shocks, electrical storm, and ICD complications were common.

  16. Partial IK1 blockade destabilizes spiral wave rotation center without inducing wave breakup and facilitates termination of reentrant arrhythmias in ventricles.

    PubMed

    Kushiyama, Yasunori; Honjo, Haruo; Niwa, Ryoko; Takanari, Hiroki; Yamazaki, Masatoshi; Takemoto, Yoshio; Sakuma, Ichiro; Kodama, Itsuo; Kamiya, Kaichiro

    2016-09-01

    It has been reported that blockade of the inward rectifier K(+) current (IK1) facilitates termination of ventricular fibrillation. We hypothesized that partial IK1 blockade destabilizes spiral wave (SW) re-entry, leading to its termination. Optical action potential (AP) signals were recorded from left ventricles of Langendorff-perfused rabbit hearts with endocardial cryoablation. The dynamics of SW re-entry were analyzed during ventricular tachycardia (VT), induced by cross-field stimulation. Intercellular electrical coupling in the myocardial tissue was evaluated by the space constant. In separate experiments, AP recordings were made using the microelectrode technique from right ventricular papillary muscles of rabbit hearts. Ba(2+) (10-50 μM) caused a dose-dependent prolongation of VT cycle length and facilitated termination of VT in perfused hearts. Baseline VT was maintained by a stable rotor, where an SW rotated around an I-shaped functional block line (FBL). Ba(2+) at 10 μM prolonged I-shaped FBL and phase-singularity trajectory, whereas Ba(2+) at 50 μM transformed the SW rotation dynamics from a stable linear pattern to unstable circular/cycloidal meandering. The SW destabilization was not accompanied by SW breakup. Under constant pacing, Ba(2+) caused a dose-dependent prolongation of APs, and Ba(2+) at 50 μM decreased conduction velocity. In papillary muscles, Ba(2+) at 50 μM depolarized the resting membrane potential. The space constant was increased by 50 μM Ba(2+) Partial IK1 blockade destabilizes SW rotation dynamics through a combination of prolongation of the wave length, reduction of excitability, and enhancement of electrotonic interactions, which facilitates termination of ventricular tachyarrhythmias. Copyright © 2016 the American Physiological Society.

  17. Effect of Channel Thickness, Annealing Temperature and Channel Length on Nanoscale Ga2O3-In2O3-ZnO Thin Film Transistor Performance.

    PubMed

    Kumaresan, Yogeenth; Pak, Yusin; Lim, Namsoo; Lee, Ryeri; Song, Hui; Kim, Tae Heon; Choi, Boran; Jung, Gun Young

    2016-06-01

    We demonstrated the effect of active layer (channel) thickness and annealing temperature on the electrical performances of Ga2O3-In2O3-ZnO (GIZO) thin film transistor (TFT) having nanoscale channel width (W/L: 500 nm/100 μm). We found that the electron carrier concentration of the channel was decreased significantly with increasing the annealing temperature (100 degrees C to 300 degrees C). Accordingly, the threshold voltage (V(T)) was shifted towards positive voltage (-12.2 V to 10.8 V). In case of channel thickness, the V(T) was shifted towards negative voltage with increasing the channel thickness. The device with channel thickness of 90 nm annealed at 200 degrees C revealed the best device performances in terms of mobility (10.86 cm2/Vs) and V(T) (0.8 V). The effect of channel length was also studied, in which the channel width, thickness and annealing temperature were kept constant such as 500 nm, 90 nm and 200 degrees C, respectively. The channel length influenced the on-current level significantly with small variation of V(T), resulting in lower value of on/off current ratio with increasing the channel length. The device with channel length of 0.5 μm showed enhanced on/off current ratio of 10(6) with minimum V(T) of 0.26 V.

  18. The Effects of a Duathlon Simulation on Ventilatory Threshold and Running Economy

    PubMed Central

    Berry, Nathaniel T.; Wideman, Laurie; Shields, Edgar W.; Battaglini, Claudio L.

    2016-01-01

    Multisport events continue to grow in popularity among recreational, amateur, and professional athletes around the world. This study aimed to determine the compounding effects of the initial run and cycling legs of an International Triathlon Union (ITU) Duathlon simulation on maximal oxygen uptake (VO2max), ventilatory threshold (VT) and running economy (RE) within a thermoneutral, laboratory controlled setting. Seven highly trained multisport athletes completed three trials; Trial-1 consisted of a speed only VO2max treadmill protocol (SOVO2max) to determine VO2max, VT, and RE during a single-bout run; Trial-2 consisted of a 10 km run at 98% of VT followed by an incremental VO2max test on the cycle ergometer; Trial-3 consisted of a 10 km run and 30 km cycling bout at 98% of VT followed by a speed only treadmill test to determine the compounding effects of the initial legs of a duathlon on VO2max, VT, and RE. A repeated measures ANOVA was performed to determine differences between variables across trials. No difference in VO2max, VT (%VO2max), maximal HR, or maximal RPE was observed across trials. Oxygen consumption at VT was significantly lower during Trial-3 compared to Trial-1 (p = 0.01). This decrease was coupled with a significant reduction in running speed at VT (p = 0.015). A significant interaction between trial and running speed indicate that RE was significantly altered during Trial-3 compared to Trial-1 (p < 0.001). The first two legs of a laboratory based duathlon simulation negatively impact VT and RE. Our findings may provide a useful method to evaluate multisport athletes since a single-bout incremental treadmill test fails to reveal important alterations in physiological thresholds. Key points Decrease in relative oxygen uptake at VT (ml·kg-1·min-1) during the final leg of a duathlon simulation, compared to a single-bout maximal run. We observed a decrease in running speed at VT during the final leg of a duathlon simulation; resulting in an increase of more than 2 minutes to complete a 5 km run. During our study, highly trained athletes were unable to complete the final 5 km run at the same intensity that they completed the initial 10 km run (in a laboratory setting). A better understanding, and determination, of training loads during multisport training may help to better periodize training programs; additional research is required. PMID:27274661

  19. Performance of the 2015 International Task Force Consensus Statement Risk Stratification Algorithm for Implantable Cardioverter-Defibrillator Placement in Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy.

    PubMed

    Orgeron, Gabriela M; Te Riele, Anneline; Tichnell, Crystal; Wang, Weijia; Murray, Brittney; Bhonsale, Aditya; Judge, Daniel P; Kamel, Ihab R; Zimmerman, Stephan L; Tandri, Harikrishna; Calkins, Hugh; James, Cynthia A

    2018-02-01

    Ventricular arrhythmias are a feared complication of arrhythmogenic right ventricular dysplasia/cardiomyopathy. In 2015, an International Task Force Consensus Statement proposed a risk stratification algorithm for implantable cardioverter-defibrillator placement in arrhythmogenic right ventricular dysplasia/cardiomyopathy. To evaluate performance of the algorithm, 365 arrhythmogenic right ventricular dysplasia/cardiomyopathy patients were classified as having a Class I, IIa, IIb, or III indication per the algorithm at baseline. Survival free from sustained ventricular arrhythmia (VT/VF) in follow-up was the primary outcome. Incidence of ventricular fibrillation/flutter cycle length <240 ms was also assessed. Two hundred twenty-four (61%) patients had a Class I implantable cardioverter-defibrillator indication; 80 (22%), Class IIa; 54 (15%), Class IIb; and 7 (2%), Class III. During a median 4.2 (interquartile range, 1.7-8.4)-year follow-up, 190 (52%) patients had VT/VF and 60 (16%) had ventricular fibrillation/flutter. Although the algorithm appropriately differentiated risk of VT/VF, incidence of VT/VF was underestimated (observed versus expected: 29.6 [95% confidence interval, 25.2-34.0] versus >10%/year Class I; 15.5 [confidence interval 11.1-21.6] versus 1% to 10%/year Class IIa). In addition, the algorithm did not differentiate survival free from ventricular fibrillation/flutter between Class I and IIa patients ( P =0.97) or for VT/VF in Class I and IIa primary prevention patients ( P =0.22). Adding Holter results (<1000 premature ventricular contractions/24 hours) to International Task Force Consensus classification differentiated risks. While the algorithm differentiates arrhythmic risk well overall, it did not distinguish ventricular fibrillation/flutter risks of patients with Class I and IIa implantable cardioverter-defibrillator indications. Limited differentiation was seen for primary prevention cases. As these are vital uncertainties in clinical decision-making, refinements to the algorithm are suggested prior to implementation. © 2018 American Heart Association, Inc.

  20. Vocal tract length development during the first two decades of life: A magnetic resonance imaging study

    NASA Astrophysics Data System (ADS)

    Vorperian, Houri K.; Chung, Moo K.; Gentry, Lindell R.; Kent, Ray D.; Choih, Celia S.; Durtschi, Reid B.; Ziegert, Andrew J.

    2005-09-01

    As the vocal tract length (VTL) increases more than twofold from infancy to adulthood, its geometric proportions change. This study assesses the developmental changes of the various hard and soft tissue structures in the vicinity of the vocal tract (VT), and evaluates the relational growth of the various structures with VTL. Magnetic resonance images from 327 cases, ages birth to age 20, were used to secure quantitative measurements of the various soft, cartilaginous and bony structures in the oral and pharyngeal regions using established procedures [Vorperian et al. (1999), (2005)]. Structures measured include: lip thickness, hard- and soft-palate length, tongue length, naso-oro-pharyngeal length, mandibular length and depth, and distance of the hyoid bone and larynx from the posterior nasal spine. Findings indicate: (a) ongoing growth of all oral and pharyngeal structures with changes in growth rate as a function of age; (b) a strong interdependency between structure orientation and its growth curve; and (c) developmental changes in the relational growth of the different VT structures with VTL. Findings provide normative data on the anatomic changes of the supra-laryngeal speech apparatus, and can be used to model the development of the VT. [Work supported by NIH-NIDCD Grants R03-DC4362 R01-DC006282, and NIH-NICHHD P30-HK03352.

  1. Results of ENHANCED Implantable Cardioverter Defibrillator Programming to Reduce Therapies and Improve Quality of Life (from the ENHANCED-ICD Study).

    PubMed

    Mastenbroek, Mirjam H; Pedersen, Susanne S; van der Tweel, Ingeborg; Doevendans, Pieter A; Meine, Mathias

    2016-02-15

    Novel implantable cardioverter defibrillator (ICD) discrimination algorithms and programming strategies have significantly reduced the incidence of inappropriate shocks, but there are still gains to be made with respect to reducing appropriate but unnecessary antitachycardia pacing (ATP) and shocks. We examined whether programming a number of intervals to detect (NID) of 60/80 for ventricular tachyarrhythmia (VT)/ventricular fibrillation (VF) detection was safe and the impact of this strategy on (1) adverse events related to ICD shocks and syncopal events; (2) ATPs/shocks; and (3) patient-reported outcomes. The "ENHANCED Implantable Cardioverter Defibrillator programming to reduce therapies and improve quality of life" study (ENHANCED-ICD study) was a prospective, safety-monitoring study enrolling 60 primary and secondary prevention patients at the University Medical Center Utrecht. Patients implanted with any type of ICD with SmartShock technology and aged 18 to 80 years were eligible to participate. In all patients, a prolonged NID 60/80 was programmed. The cycle length for VT/fast VT/VF was 360/330/240 ms, respectively. Programming a NID 60/80 proved safe for ICD patients. Because of the new programming strategy, unnecessary ICD therapy was prevented in 10% of ENHANCED-ICD patients during a median follow-up period of 1.3 years. With respect to patient-reported outcomes, levels of distress were highest and perceived health status lowest at the time of implantation, which both gradually improved during follow-up. In conclusion, the ENHANCED-ICD study demonstrates that programming a NID 60/80 for VT/VF detection is safe for ICD patients and does not negatively impact their quality of life. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Developmental Sexual Dimorphism of the Oral and Pharyngeal Portions of the Vocal Tract: An Imaging Study

    ERIC Educational Resources Information Center

    Vorperian, Houri K.; Wang, Shubing; Schimek, E. Michael; Durtschi, Reid B.; Kent, Ray D.; Gentry, Lindell R.; Chung, Moo K.

    2011-01-01

    Purpose: The anatomic origin for prepubertal vowel acoustic differences between male and female subjects remains unknown. The purpose of this study is to examine developmental sex differences in vocal tract (VT) length and its oral and pharyngeal portions. Method: Nine VT variables were measured from 605 imaging studies (magnetic resonance imaging…

  3. Low tidal volume and high positive end-expiratory pressure mechanical ventilation results in increased inflammation and ventilator-associated lung injury in normal lungs.

    PubMed

    Hong, Caron M; Xu, Da-Zhong; Lu, Qi; Cheng, Yunhui; Pisarenko, Vadim; Doucet, Danielle; Brown, Margaret; Aisner, Seena; Zhang, Chunxiang; Deitch, Edwin A; Delphin, Ellise

    2010-06-01

    Protective mechanical ventilation with low tidal volume (Vt) and low plateau pressure reduces mortality and decreases the length of mechanical ventilation in patients with acute respiratory distress syndrome. Mechanical ventilation that will protect normal lungs during major surgical procedures of long duration may improve postoperative outcomes. We performed an animal study comparing 3 ventilation strategies used in the operating room in normal lungs. We compared the effects on pulmonary mechanics, inflammatory mediators, and lung tissue injury. Female pigs were randomized into 3 groups. Group H-Vt/3 (n = 6) was ventilated with a Vt of 15 mL/kg predicted body weight (PBW)/positive end-expiratory pressure (PEEP) of 3 cm H(2)O, group L-Vt/3 (n = 6) with a Vt of 6 mL/kg PBW/PEEP of 3 cm H(2)O, and group L-Vt/10 (n = 6) with a Vt of 6 mL/kg PBW/PEEP of 10 cm H(2)O, for 8 hours. Hemodynamics, airway mechanics, arterial blood gases, and inflammatory markers were monitored. Bronchoalveolar lavage (BAL) was analyzed for inflammatory markers and protein concentration. The right lower lobe was assayed for mRNA of specific cytokines. The right lower lobe and right upper lobe were evaluated histologically. In contrast to groups H-Vt/3 and L-Vt/3, group L-Vt/10 exhibited a 6-fold increase in inflammatory mediators in BAL (P < 0.001). Cytokines in BAL were similar in groups H-Vt/3 and L-Vt/3. Group H-Vt/3 had a significantly lower lung injury score than groups L-Vt/3 and L-Vt/10. Comparing intraoperative strategies, ventilation with high PEEP resulted in increased production of inflammatory markers. Low PEEP resulted in lower levels of inflammatory markers. High Vt/low PEEP resulted in less histologic lung injury.

  4. Changes in ventilatory threshold with exercise training in a sedentary population: the HERITAGE Family Study.

    PubMed

    Gaskill, S E; Walker, A J; Serfass, R A; Bouchard, C; Gagnon, J; Rao, D C; Skinner, J S; Wilmore, J H; Leon, A S

    2001-11-01

    The purpose of this study was to evaluate the effect of exercise training intensity relative to the ventilatory threshold (VT) on changes in work (watts) and VO2 at the ventilatory threshold and at maximal exercise in previously sedentary participants in the HERITAGE Family Study. We hypothesized that those who exercised below their VT would improve less in VO2 at the ventilatory threshold (VO2vt) and VO2max than those who trained at an intensity greater than their VT. Supervised cycle ergometer training was performed at the 4 participating clinical centers, 3 times a week for 20 weeks. Exercise training progressed from the HR corresponding to 55% VO2max for 30 minutes to the HR associated with 75% VO2max for 50 minutes for the final 6 weeks. VT was determined at baseline and after exercise training using standardized methods. 432 sedentary white and black men (n = 224) and women (n = 208), aged 17 to 65 years, were retrospectively divided into groups based on whether exercise training was initiated below, at, or above VT. 1) Training intensity (relative to VT) accounting for about 26% of the improvement in VO2vt (R2 = 0.26, p < 0.0001). 2) The absolute intensity of training in watts (W) accounted for approximately 56% of the training effect at VT (R2 = 0.56, p < 0.0001) with post-training watts at VT (VT(watts)) being not significantly different than W during training (p > 0.70). 3) Training intensity (relative to VT) had no effect on DeltaVO2max. These data clearly show that as a result of aerobic training both the VO2 and W associated with VT respond and become similar to the absolute intensity of sustained (3 x /week for 50 min) aerobic exercise training. Higher intensities of exercise, relative to VT, result in larger gains in VO2vt but not in VO2max.

  5. New Features of Electrocardiogram in a Case Report of Arrhythmogenic Right Ventricular Cardiomyopathy: A Care-Compliant Article.

    PubMed

    Pei, Haifeng; Yu, Qiujun; Su, Xiaohua; Wang, Zhen; Zhao, Heng; Yang, Dachun; Yang, Yongjian; Li, De

    2016-04-01

    Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a crucial health problem. With sudden death often being the first presentation, early diagnosis for ARVC is essential. Up to date, electrocardiogram (ECG) is a widely used diagnostic method without invasive harms. To diagnose and treat ARVC as well as possible, we should clearly elucidate its pathophysiological alterations. A 66-year-old farmer presented to the Emergency Department with continuous palpitation, chest tightness, profuse sweating, and nausea with no obvious predisposing causes. An ECG indicated ventricular tachycardia (VT). The patient experienced a sudden drop in blood pressure and acute confusion. After an immediate electrical conversion, his consciousness was gradually restored, and symptoms relieved. The patient was then transferred to the Department of Cardiology to receive ECG, echocardiography, coronary angiogram, biochemical assays, endocardiac tracing, and radiofrequency ablation. In the end, he was diagnosed with ARVC, evidenced by bilateral ventricle dilation and epsilon waves in leads V1-V3. Appropriate therapies were provided for this patient including pharmacological intervention and radiofrequency ablation. Although the diagnosis of ARVC is not difficult, this patient's ECG manifested several interesting features and should be further investigated: T wave inversions were found extensively in the anterior and inferior leads, revealing the involvement of bilateral ventricles; VTs with different morphologies and cycle lengths were found, and some VTs manifested the feature of irregularly irregular rhythm, reminding us to carefully differentiate some special VTs from atrial fibrillation (AF); and epsilon waves gradually appeared in leads V1-V3 and avR since the onset of ARVC. Most importantly, the epsilon waves behind QRS complex appeared in both sinus rhythm and ventricular premature beats/VT originating from cardiac apex, whereas the epsilon waves prior to QRS complex occurred in VT originating from right ventricular outflow tract (RVOT). The features of T wave inversion and epsilon wave in ECGs and the appearance of VTs with different morphologies can reflect the progression of ARVC. The position relationship between epsilon wave and QRS complex in VT depends on ventricular activation sequence, that is, the localization of epsilon wave depends on where VT is originating from.

  6. Presence of a temperature gradient among genital tract portions and the thermal changes within these portions over the estrous cycle in beef cows.

    PubMed

    El-Sheikh Ali, Hossam; Kitahara, Go; Tamura, Youji; Kobayashi, Ikuo; Hemmi, Koichiro; Torisu, Shidow; Sameshima, Hiroshi; Horii, Yoichiro; Zaabel, Samy; Kamimura, Shunichi

    2013-01-01

    The aim of the present study was to describe the temperature of the different portions of the female genital tract and their relation to rectal temperature and to investigate the effect of steroid hormones profiles on these variables over the estrous cycle in cattle. Four nonpregnant Japanese Black cows were investigated daily over two successive estrous cycles using a digital thermometer with a long probe and rounded-end sensor to record the temperature of the rectum (RT), vagina (VT), cervix (CT), uterine body (UBT) and uterine horns (UHT). Blood samples were collected immediately before temperature recording to assay peripheral levels of progesterone (P(4)) and estradiol-17β (E(2)). Moreover, transrectal ultrasonography was carried out after temperature recording to monitor the ovulatory follicle and track ovulation. During the experiment, the ambient temperature and relative humidity were recorded for further calculation of the temperature humidity index (THI). The temperature within the genital tracts in these cows progressively increased towards the uterine horns from the vagina. The VT, CT, UBT and UHTs were significantly higher in association with peripheral P(4) concentrations greater than 4 ng/ml (mid-luteal phase) when compared with lower peripheral P(4) concentrations. The VT was more significantly (P<0.01) correlated to the CT, UBT and UHTs than RT. In conclusion, a temperature gradient was present among the vagina, cervix and uterus over the estrous cycle, and changes in peripheral P(4) concentrations were associated with the thermal variations within these portions. The VT could be more beneficial than RT in monitoring temperature of deeper portions of the female genital tract in bovine.

  7. Presence of a Temperature Gradient Among Genital Tract Portions and the Thermal Changes Within These Portions Over the Estrous Cycle in Beef Cows

    PubMed Central

    EL-SHEIKH ALI, Hossam; KITAHARA, Go; TAMURA, Youji; KOBAYASHI, Ikuo; HEMMI, Koichiro; TORISU, Shidow; SAMESHIMA, Hiroshi; HORII, Yoichiro; ZAABEL, Samy; KAMIMURA, Shunichi

    2012-01-01

    Abstract The aim of the present study was to describe the temperature of the different portions of the female genital tract and their relation to rectal temperature and to investigate the effect of steroid hormones profiles on these variables over the estrous cycle in cattle. Four nonpregnant Japanese Black cows were investigated daily over two successive estrous cycles using a digital thermometer with a long probe and rounded-end sensor to record the temperature of the rectum (RT), vagina (VT), cervix (CT), uterine body (UBT) and uterine horns (UHT). Blood samples were collected immediately before temperature recording to assay peripheral levels of progesterone (P4) and estradiol-17β (E2). Moreover, transrectal ultrasonography was carried out after temperature recording to monitor the ovulatory follicle and track ovulation. During the experiment, the ambient temperature and relative humidity were recorded for further calculation of the temperature humidity index (THI). The temperature within the genital tracts in these cows progressively increased towards the uterine horns from the vagina. The VT, CT, UBT and UHTs were significantly higher in association with peripheral P4 concentrations greater than 4 ng/ml (mid-luteal phase) when compared with lower peripheral P4 concentrations. The VT was more significantly (P<0.01) correlated to the CT, UBT and UHTs than RT. In conclusion, a temperature gradient was present among the vagina, cervix and uterus over the estrous cycle, and changes in peripheral P4 concentrations were associated with the thermal variations within these portions. The VT could be more beneficial than RT in monitoring temperature of deeper portions of the female genital tract in bovine. PMID:23095515

  8. Accuracy of tidal volume delivered by home mechanical ventilation during mouthpiece ventilation

    PubMed Central

    Prigent, Helene; Falaize, Line; Leroux, Karl; Santos, Dante; Vaugier, Isabelle; Orlikowski, David; Lofaso, Frederic

    2016-01-01

    The aim of our study was to evaluate efficacy and reliability of currently available ventilators for mouthpiece ventilation (MPV). Five life-support home ventilators were assessed in a bench test using different settings simulating the specificities of MPV, such as intermittent circuit disconnection and presence of continuous leaks. The intermittent disconnection of the circuit caused relevant swings in the delivered tidal volume (VT), showing a VT overshoot during the disconnection periods and a VT decrease when the interface was reconnected to the test lung. The five ventilators showed substantial differences in the number of respiratory cycles necessary to reach a stable VT in the volume-controlled setting, ranging from 1.3 ± 0.6 to 7.3 ± 1.2 cycles. These differences were less accentuated in the volume-assisted setting (MPV-dedicated mode, when available). Our data show large differences in the capacity of the different ventilators to deal with the rapidly changing respiratory load features that characterize MPV, which can be further accentuated according to the used ventilator setting. The dedicated MPV modes allow improvement in the performance of ventilators only in some defined situations. This has practical consequences for the choice of the ventilator to be used for MPV in a specific patient. PMID:27146811

  9. High Prevalence of Suboptimal Vitamin D Status and Bone Loss in Adult Short Bowel Syndrome Even After Weaning Off Parenteral Nutrition.

    PubMed

    Fan, Shengxian; Ni, Xiaodong; Wang, Jian; Zhang, Yongliang; Tao, Shen; Kong, Wencheng; Li, Yousheng; Li, Jieshou

    2017-04-01

    Previous studies have noticed the high incidence of suboptimal vitamin D (VtD) status and bone loss in short bowel syndrome (SBS) with parenteral nutrition (PN) dependence. However, limited data have focused on adult SBS without PN dependence. Therefore, our objective was to investigate the incidence and risk factors of suboptimal VtD status and bone loss in adult SBS even after weaning off PN. We performed a prospective study of 60 adult patients with SBS. Serum 25-hydroxyvitamin D (25-OHD) was measured by radioimmunoassay. Bone mineral density (BMD) was measured using dual-energy x-ray absorptiometry (DEXA). Medical records and various laboratory parameters were collected in all participants. Suboptimal VtD status was identified in all individuals, including 3 (5.0%) with VtD insufficiency and 57 (95.0%) with VtD deficiency. Residual small bowel length (B, 0.072, P = .001) and duration of SBS (B, -0.066, P = .020) were both significantly correlated with suboptimal VtD levels. Overall, only 2 patients presented a normal BMD; osteopenia and osteoporosis were noted in 41 (68.3%) and 17 (28.3%) individuals, respectively. Low 25-OHD concentration was associated with a decreased BMD (B, 0.065, P = .029). There were no other demographic characteristics or clinical examinations associated with suboptimal VtD levels and bone loss. Suboptimal VtD status and bone loss were common in adult SBS even after weaning off PN. Despite routine oral VtD supplementation, most patients did not achieve satisfactory status. This emphasizes the critical importance of routine surveillance of 25-OHD and BMD, as well as consideration of alternative methods of supplementation after weaning off PN.

  10. Physiologic responses during indoor cycling.

    PubMed

    Battista, Rebecca A; Foster, Carl; Andrew, Jessica; Wright, Glenn; Lucia, Alejandro; Porcari, John P

    2008-07-01

    During the last decade, there has been active interest in indoor cycling (e.g., spinning) as a method of choreographed group exercise. Recent studies have suggested that exercise intensity during indoor cycling may be quite high and may transiently exceed Vo2max. This study sought to confirm these findings, as the apparent high intensity of indoor cycling has implications for both the efficacy and the risk of indoor cycling as an exercise method. Twenty healthy female students performed an incremental exercise test to define Vo2max and performed 2 videotaped indoor exercise classes lasting 45 minutes and 35 minutes. Vo2, heart rate (HR), and rating of perceived exertion (RPE) were measured during the indoor cycling classes, with Vo2 data integrated in 30-second intervals. The mean %Vo2max during the indoor cycling classes was modest (74 +/- 14% Vo2max and 66 +/- 14%Vo2max, respectively). However, 52% and 35% of the time during the 45- and 35-minute classes was spent at intensities greater than the ventilatory threshold (VT). The HR response indicated that 35% and 38% of the session time was above the HR associated with VT. In 10 of the 40 exercise sessions, there were segments in which the momentary Vo2 exceeded Vo2max observed during incremental testing, and the cumulative time with exercise intensity greater than Vo2max ranged from 0.5 to 14.0 minutes. It can be concluded that although the intensity of indoor cycling in healthy, physically active women is moderate, there are frequent observations of transient values of Vo2 exceeding Vo2max, and a substantial portion of the exercise bouts at intensities greater than VT. As such, the data suggest that indoor cycling must be considered a high-intensity exercise mode of exercise training, which has implications for both efficacy and risk.

  11. Change in VO2max and time trial performance in response to high-intensity interval training prescribed using ventilatory threshold.

    PubMed

    Astorino, Todd A; deRevere, Jamie; Anderson, Theodore; Kellogg, Erin; Holstrom, Patrick; Ring, Sebastian; Ghaseb, Nicholas

    2018-06-19

    Completion of high-intensity interval training (HIIT) leads to significant increases in maximal oxygen uptake (VO 2max ) and oxidative capacity. However, individual responses to HIIT have been identified as approximately 20-40% of individuals show no change in VO 2max , which may be due to the relatively homogeneous approach to implementing HIIT. This study tested the effects of HIIT prescribed using ventilatory threshold (VT) on changes in VO 2max and cycling performance. Fourteen active men and women (age and VO 2max  = 27 ± 8 year and 38 ± 4 mL/kg/min) underwent nine sessions of HIIT, and 14 additional men and women (age and VO 2max  = 22 ± 3 year and 40 ± 5 mL/kg/min) served as controls. Training was performed on a cycle ergometer at a work rate equal to 130%VT and consisted of eight to ten 1 min bouts interspersed with 75 s of recovery. At baseline and post-testing, they completed progressive cycling to exhaustion to determine VO 2max , and on a separate day, a 5 mile cycling time trial. Compared to the control group, HIIT led to significant increases in VO 2max (6%, p = 0.007), cycling performance (2.5%, p = 0.003), and absolute VT (9 W, p = 0.005). However, only 57% of participants revealed meaningful increases in VO 2max and cycling performance in response to training, and two showed no change in either outcome. A greater volume of HIIT may be needed to maximize the training response for all individuals.

  12. Validity of electromyographic fatigue threshold as a noninvasive method for tracking changes in ventilatory threshold in college-aged men.

    PubMed

    Kendall, Kristina L; Smith, Abbie E; Graef, Jennifer L; Walter, Ashley A; Moon, Jordan R; Lockwood, Christopher M; Beck, Travis W; Cramer, Joel T; Stout, Jeffrey R

    2010-01-01

    The submaximal electromyographic fatigue threshold test (EMG(FT)) has been shown to be highly correlated to ventilatory threshold (VT) as determined from maximal graded exercise tests (GXTs). Recently, a prediction equation was developed using the EMG(FT) value to predict VT. The aim of this study, therefore, was to determine if this new equation could accurately track changes in VT after high-intensity interval training (HIIT). Eighteen recreationally trained men (mean +/- SD; age 22.4 +/- 3.2 years) performed a GXT to determine maximal oxygen consumption rate (V(O2)peak) and VT using breath-by-breath spirometry. Participants also completed a discontinuous incremental cycle ergometer test to determine their EMGFT value. A total of four 2-minute work bouts were completed to obtain 15-second averages of the electromyographic amplitude. The resulting slopes from each successive work bout were used to calculate EMG(FT). The EMG(FT) value from each participant was used to estimate VT from the recently developed equation. All participants trained 3 days a week for 6 weeks. Training consisted of 5 sets of 2-minute work bouts with 1 minute of rest in between. Repeated-measures analysis of variance indicated no significant difference between actual and predicted VT values after 3 weeks of training. However, there was a significant difference between the actual and predicted VT values after 6 weeks of training. These findings suggest that the EMG(FT) may be useful when tracking changes in VT after 3 weeks of HIIT in recreationally trained individuals. However, the use of EMG(FT) to predict VT does not seem to be valid for tracking changes after 6 weeks of HIIT. At this time, it is not recommended that EMG(FT) be used to predict and track changes in VT.

  13. Vocal Tract Adjustments of Dysphonic and Non-Dysphonic Women Pre- and Post-Flexible Resonance Tube in Water Exercise: A Quantitative MRI Study.

    PubMed

    Yamasaki, Rosiane; Murano, Emi Z; Gebrim, Eloisa; Hachiya, Adriana; Montagnoli, Arlindo; Behlau, Mara; Tsuji, Domingos

    2017-07-01

    To compare vocal tract (VT) adjustments of dysphonic and non-dysphonic women before and after flexible resonance tube in water exercise (FRTWE) at rest and during phonation using magnetic resonance imaging. Prospective study. Twenty women, aged 20-40 years, 10 dysphonic with vocal nodules (VNG) and 10 controls (CG), underwent four sets of sagittal VT MRI: two pre-FRTWE, at rest and during phonation, and two post-FRTWE, during phonation and at rest. The subjects performed 3 minutes of exercise. Nine parameters at rest and 21 during phonation were performed. Pre-FRTWE, eight significant differences were found, three at rest and five during phonation: at rest - laryngeal vestibule area, distance from epiglottis to pharyngeal posterior wall (PPW) and interarytenoid complex length were smaller in the VNG; during phonation - laryngeal vestibule area, angle between PPW and vocal fold (VF), epiglottis to PPW, and anterior commissure of the larynx to laryngeal posterior wall were smaller in the VNG; tongue area was larger in the VNG. Post-FRTWE, only three significant differences were found, two during phonation and one at rest: during phonation - angle between PPW and VF and the membranous portion of the VF length were smaller in the VNG; at rest - distance from epiglottis to PPW was smaller in the VNG. Results suggest that the habitual VT adjustments of dysphonic and non-dysphonic women are different at rest and during phonation. The FRTWE promoted positive VT changes in the VNG, reducing the intergroup differences. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  14. Federal Logistics Information Systems. FLIS Procedures Manual. Document Identifier Code Input/Output Formats (Variable Length). Volume 9.

    DTIC Science & Technology

    1997-04-01

    DATA COLLABORATORS 0001N B NQ 8380 NUMBER OF DATA RECEIVERS 0001N B NQ 2533 AUTHORIZED ITEM IDENTIFICATION DATA COLLABORATOR CODE 0002 ,X B 03 18 TD...01 NC 8268 DATA ELEMENT TERMINATOR CODE 000iX VT 9505 TYPE OF SCREENING CODE 0001A 01 NC 8268 DATA ELEMENT TERMINATOR CODE 000iX VT 4690 OUTPUT DATA... 9505 TYPE OF SCREENING CODE 0001A 2 89 2910 REFERENCE NUMBER CATEGORY CODE (RNCC) 0001X 2 89 4780 REFERENCE NUMBER VARIATION CODE (RNVC) 0001 N 2 89

  15. Fully automated three-dimensional microscopy system

    NASA Astrophysics Data System (ADS)

    Kerschmann, Russell L.

    2000-04-01

    Tissue-scale structures such as vessel networks are imaged at micron resolution with the Virtual Tissue System (VT System). VT System imaging of cubic millimeters of tissue and other material extends the capabilities of conventional volumetric techniques such as confocal microscopy, and allows for the first time the integrated 2D and 3D analysis of important tissue structural relationships. The VT System eliminates the need for glass slide-mounted tissue sections and instead captures images directly from the surface of a block containing a sample. Tissues are en bloc stained with fluorochrome compounds, embedded in an optically conditioned polymer that suppresses image signals form dep within the block , and serially sectioned for imaging. Thousands of fully registered 2D images are automatically captured digitally to completely convert tissue samples into blocks of high-resolution information. The resulting multi gigabyte data sets constitute the raw material for precision visualization and analysis. Cellular function may be seen in a larger anatomical context. VT System technology makes tissue metrics, accurate cell enumeration and cell cycle analyses possible while preserving full histologic setting.

  16. Combining perceptual regulation and exergaming for exercise prescription in low-active adults with and without cognitive impairment.

    PubMed

    McAuliffe, Liam; Parfitt, Gaynor C; Eston, Roger G; Gray, Caitlin; Keage, Hannah A D; Smith, Ashleigh E

    2018-01-01

    Exercise adherence in already low-active older adults with and without mild cognitive impairment (MCI) remains low. Perceptual regulation and exergaming may facilitate future exercise behaviour by improving the affective experience, however evidence that this population can perceptually regulate is lacking. To explore this, we investigated 1) perceptual regulation of exercise intensity during either exergaming or regular ergometer cycling and 2) explored affective responses. Thirty-two low active older adults (73.9 ± 7.3 years, n  = 16, 8 females) with or without MCI (70.9 ± 5.5 years, n  = 16, 11 females) participated in a sub-maximal fitness assessment to determine ventilatory threshold (VT) and two experimental sessions (counterbalanced: exergaming or regular ergometer cycling). Experimental sessions consisted 21-min of continuous cycling with 7-min at each: RPE 9, 11 and 13. Oxygen consumption (VO 2 ), heart rate (HR), and affect (Feeling Scale) were obtained throughout the exercise. VO 2 ( p  < 0.01) and HR ( p  < 0.01) increased linearly with RPE, but were not significantly different between exercise modes or cognitive groups. At RPE 13, participants worked above VT in both modes (exergaming: 115.7 ± 27.3; non-exergaming 114.1 ± 24.3 VO 2 (%VT)). Regardless of cognitive group, affect declined significantly as RPE increased ( p  < 0.01). However on average, affect remained pleasant throughout and did not differ between exercise modes or cognitive groups. These results suggest low-active older adults can perceptually regulate exercise intensity, regardless of cognition or mode. At RPE 13, participants regulated above VT, at an intensity that improves cardiorespiratory fitness long-term, and affect remained positive in the majority of participants, which may support long-term physical activity adherence.

  17. Noninvasive Determination of Anaerobic Threshold Based on the Heart Rate Deflection Point in Water Cycling.

    PubMed

    Pinto, Stephanie S; Brasil, Roxana M; Alberton, Cristine L; Ferreira, Hector K; Bagatini, Natália C; Calatayud, Joaquin; Colado, Juan C

    2016-02-01

    This study compared heart rate (HR), oxygen uptake (VO2), percentage of maximal HR (%HRmax), percentage of maximal VO2, and cadence (Cad) related to the anaerobic threshold (AT) during a water cycling maximal test between heart rate deflection point (HRDP) and ventilatory (VT) methods. In addition, the correlations between both methods were assessed for all variables. The test was performed by 27 men in a cycle ergometer in an aquatic environment. The protocol started at a Cad of 100 b · min(-1) for 3 minutes with subsequent increments of 15 b · min(-1) every 2 minutes until exhaustion. A paired two-tailed Student's t-test was used to compare the variables between the HRDP and VT methods. The Pearson product-moment correlation test was used to correlate the same variables determined by the 2 methods. There was no difference in HR (166 ± 13 vs. 166 ± 13 b · min(-1)), VO2 (38.56 ± 6.26 vs. 39.18 ± 6.13 ml · kg(-1) · min(-1)), %HRmax (89.24 ± 3.84 vs. 89.52 ± 4.29%), VO2max (70.44 ± 7.99 vs. 71.64 ± 8.32%), and Cad (174 ± 14 b · min(-1) vs. 171 ± 8 b · min(-1)) related to AT between the HRDP and VT methods. Moreover, significant relationships were found between the methods to determine the AT for all variables analyzed (r = 0.57-0.97). The estimation of the HRDP may be a noninvasive and easy method to determine the AT, which could be used to adapt individualized training intensities to practitioners during water cycling classes.

  18. β-alanine Supplementation Fails to Increase Peak Aerobic Power or Ventilatory Threshold in Aerobically Trained Males.

    PubMed

    Greer, Beau Kjerulf; Katalinas, Matthew E; Shaholli, Danielle M; Gallo, Paul M

    2016-01-01

    The purpose of the present study was to determine the effect of 30 days of β-alanine supplementation on peak aerobic power and ventilatory threshold (VT) in aerobically fit males. Fourteen males (28.8 ± 9.8 yrs) were assigned to either a β-alanine (SUPP) or placebo (PLAC) group; groups were matched for VT as it was the primary outcome measure. β-alanine supplementation consisted of 3 g/day for 7 days, and 6 g/day for the remaining 23 days. Before and after the supplementation period, subjects performed a continuous, graded cycle ergometry test to determine VO2 peak and VT. Metabolic data were analyzed using a 2 × 2 ANOVA with repeated measures. Thirty days of β-alanine supplementation (SUPP) did not increase VO2 peak (4.05 ± 0.6 vs. 4.14 ± 0.6 L/min) as compared to the placebo (PLAC) group (3.88 ± 0.2 vs. 3.97 ± 0.2 L/min) (p > .05). VT did not significantly improve in either the SUPP (3.21 ± 0.5 vs. 3.33 ± 0.5 L/min) or PLAC (3.19 ± 0.1 vs. 3.20 ± 0.1 L/min) group (p > .05). In conclusion, 30 days of β-alanine supplementation had no effect on VO2 peak or VT in aerobically trained athletes.

  19. Effects of a short-term personalized Intermittent Work Exercise Program (IWEP) on maximal cardio-respiratory function and endurance parameters among healthy young and older seniors.

    PubMed

    Vogel, T; Leprêtre, P-M; Brechat, P-H; Lonsdorfer, E; Benetos, A; Kaltenbach, G; Lonsdorfer, J

    2011-12-01

    The aim of this study was to evaluate the efficiency of a short-term Intermittent Work Exercise Program (IWEP) among healthy elderly subjects. This longitudinal prospective study took place at the Strasbourg University Hospital geriatric department. One hundred and fifty older volunteers, previously determined as being free from cardiac and pulmonary disease, were separated into two age groups: the "young senior" (60.2 ± 3.1 yr) and the "older senior" groups (70.8 ± 5.2 yr). These groups were then subdivided by gender into the "young female senior", "young male senior" "older female senior" and "older male senior" groups. Before and after the IWEP, all subjects were asked to perform an incremental cycle exercise to obtain their first ventilatory threshold (VT1), maximal tolerated power (MTP), peak oxygen uptake (VO2peak) and maximal minute ventilation (MMV). The IWEP consisted of a 30-min cycling exercise which took place twice a week, and was divided into six 5-min stages consisting of 4 min at VT1 intensity and 1 min at 90% MTP. An assessment was made of the effects of the IWEP on maximal cardio-respiratory function (MTP, VO2peak, MMV) and endurance parameters (VT1, heart rate [HR] measured at pretraining VT1 and lactate concentrations at pre-training MTP). This short-term training program resulted in a significant increase of MTP (from 13.2% to 20.6%), VO2peak (from 8.9% to 16.6%) and MMV (from 11.1% to 21.8%) in all groups (p<0.05). VT1 improved from 21% at pretraining to 27%, while HR at pre-training VT1 as well as lactate concentrations at pre-training MTP decreased significantly in all groups (p<0.05). The post-training values for VO2peak and MMV of the "older seniors" were not significantly different (p>0.05) from the "young seniors" pre-training values for the same parameters. The most striking finding in this study is that after only 9 weeks, our short-term "individually-tailored" IWEP significantly improved both maximal cardio-respiratory function and endurance parameters in healthy, previously untrained seniors.

  20. Thermal analysis of the vortex tube based thermocycler for fast DNA amplification: Experimental and two-dimensional numerical results

    NASA Astrophysics Data System (ADS)

    Raghavan, V.; Whitney, Scott E.; Ebmeier, Ryan J.; Padhye, Nisha V.; Nelson, Michael; Viljoen, Hendrik J.; Gogos, George

    2006-09-01

    In this article, experimental and numerical analyses to investigate the thermal control of an innovative vortex tube based polymerase chain reaction (VT-PCR) thermocycler are described. VT-PCR is capable of rapid DNA amplification and real-time optical detection. The device rapidly cycles six 20μl 96bp λ-DNA samples between the PCR stages (denaturation, annealing, and elongation) for 30cycles in approximately 6min. Two-dimensional numerical simulations have been carried out using computational fluid dynamics (CFD) software FLUENT v.6.2.16. Experiments and CFD simulations have been carried out to measure/predict the temperature variation between the samples and within each sample. Heat transfer rate (primarily dictated by the temperature differences between the samples and the external air heating or cooling them) governs the temperature distribution between and within the samples. Temperature variation between and within the samples during the denaturation stage has been quite uniform (maximum variation around ±0.5 and 1.6°C, respectively). During cooling, by adjusting the cold release valves in the VT-PCR during some stage of cooling, the heat transfer rate has been controlled. Improved thermal control, which increases the efficiency of the PCR process, has been obtained both experimentally and numerically by slightly decreasing the rate of cooling. Thus, almost uniform temperature distribution between and within the samples (within 1°C) has been attained for the annealing stage as well. It is shown that the VT-PCR is a fully functional PCR machine capable of amplifying specific DNA target sequences in less time than conventional PCR devices.

  1. Acute amiodarone promotes drift and early termination of spiral wave re-entry.

    PubMed

    Nakagawa, Harumichi; Honjo, Haruo; Ishiguro, Yuko S; Yamazaki, Masatoshi; Okuno, Yusuke; Harada, Masahide; Takanari, Hiroki; Sakuma, Ichiro; Kamiya, Kaichiro; Kodama, Itsuo

    2010-07-01

    Intravenous application of amiodarone is commonly used in the treatment of life-threatening arrhythmias, but the underlying mechanism is not fully understood. The purpose of the present study is to investigate the acute effects of amiodarone on spiral wave (SW) re-entry, the primary organization machinery of ventricular tachycardia/fibrillation (VT/VF), in comparison with lidocaine. A two-dimensional ventricular myocardial layer was obtained from 24 Langendorff-perfused rabbit hearts, and epicardial excitations were analyzed by high-resolution optical mapping. During basic stimulation, amiodarone (5 microM) caused prolongation of action potential duration (APD) by 5.6%-9.1%, whereas lidocaine (15 microM) caused APD shortening by 5.0%-6.4%. Amiodarone and lidocaine reduced conduction velocity similarly. Ventricular tachycardias induced by DC stimulation in the presence of amiodarone were of shorter duration (sustained-VTs >30 s/total VTs: 2/58, amiodarone vs 13/52, control), whereas those with lidocaine were of longer duration (22/73, lidocaine vs 14/58, control). Amiodarone caused prolongation of VT cycle length and destabilization of SW re-entry, which is characterized by marked prolongation of functional block lines, frequent wavefront-tail interactions near the rotation center, and considerable drift, leading to its early annihilation via collision with anatomical boundaries. Spiral wave re-entry in the presence of lidocaine was more stabilized than in control. In the anisotropic ventricular myocardium, amiodarone destabilizes SW re-entry facilitating its early termination. Lidocaine, in contrast, stabilizes SW re-entry resulting in its persistence.

  2. Maximal lactate steady state determination with a single incremental test exercise.

    PubMed

    Laplaud, David; Guinot, Michel; Favre-Juvin, Anne; Flore, Patrice

    2006-03-01

    The aim of this study was to determine whether the power output associated with a maximal lactate steady state (MLSS) (.W(MLSS)) can be assessed using a single incremental cycling test. Eleven recreational sportsmen (age: 22+/-1 years, height: 175+/-6 cm, weight: 71+/-5 kg) volunteered to participate in the study. For each subject the first and second ventilatory thresholds (VT(1) and VT(2), respectively) and the power output corresponding to (respiratory exchange ratio) RER=1.00 were determined during an incremental test to exhaustion. Thereafter, each subject performed several 30-min constant load tests to determine MLSS. The workload used in the first constant test was set to the .W(RER=1.00) determined during the incremental test. .W(VT1) (175+/-24 W) and .W(VT2) (265+/-31 W) were significantly different from .W(MLSS )(220+/-36 W). Whereas, .W(RER=1.00) (224+/-33 W) was similar to .W(MLSS). HR, RER and .VE were significantly different between the 10th and the 30th minutes when exercising at .W(RER=1.00) and at .W(MLSS). In contrast, .VO(2) and .VCO(2) were stable over those 30-min constant tests. Power output at VT(1), RER=1.00 and VT(2) were all correlated to .W(MLSS) but the relationship was stronger between RER=1.00 and MLSS (R (2)=0.95). The present study shows that the power output associated with a RER value equal to 1.00 during an incremental test does not differ from that determined for MLSS. Hence, the MLSS can be estimated with a single exercise test.

  3. Instrument development in the measurement of unsupported arm exercise endurance in normal adult subjects.

    PubMed

    Breslin, E H; Adams, E; Lutz, A; Roy, C

    1993-06-01

    Many daily activities, from basic grooming to employment tasks, require adequate unsupported arm endurance (UAE). We developed an electromechanical device to measure UAE endurance. The purpose of this study was to standardize the instrument for two rates of arm motion, moderate and slow, in 18 normal adult subjects (FEVI = 3.7L +/- .78, FVC = 4.2L +/- .74, FEV1/FVC = 1.1 +/- .08). Exercise endurance limits, and the following metabolic, ventilatory, and sensation responses were determined at rest prior to exercise and at end-exercise limits for both rates of UAE:minute ventilation (Ve), tidal volume (VT), respiratory rate (RR), duty cycle (Ti/Ttot), oxygen uptake (VO2), carbon dioxide production (VCO2), inspiratory flow (VT/Ti), heart rate (HR), and visual analog scale measurements (VAS) of dyspnea (D), respiratory effort (RE), and arm fatigue (AF). Significance increases from baseline rest were shown at the endurance limits for both rates of UAE in: VO2, VCO2, Ve, VT, RR, VT/Ti, HR, VAS-D, VAS-RE, and VAS-AF. There were no changes in Ti/Ttot and SaO2 with UAE. Peak VO2, RR, Ve, VT/Ti, and VAS-D with moderate exercise were significantly greater than slow UAE; and there was a trend increase in peak HR for moderate as opposed to slow rate UAE. Despite these differences, the endurance time between the two rates of UAE were similar. These data provide standards against which UAE in COPD can be evaluated.

  4. Physiological Correlates of Endurance Time Variability during Constant-Workrate Cycling Exercise in Patients with COPD

    PubMed Central

    Vivodtzev, Isabelle; Gagnon, Philippe; Pepin, Véronique; Saey, Didier; Laviolette, Louis; Brouillard, Cynthia; Maltais, François

    2011-01-01

    Rationale The endurance time (Tend) during constant-workrate cycling exercise (CET) is highly variable in COPD. We investigated pulmonary and physiological variables that may contribute to these variations in Tend. Methods Ninety-two patients with COPD completed a CET performed at 80% of peak workrate capacity (Wpeak). Patients were divided into tertiles of Tend [Group 1: <4 min; Group 2: 4–6 min; Group 3: >6 min]. Disease severity (FEV1), aerobic fitness (Wpeak, peak oxygen consumption [ peak], ventilatory threshold [ VT]), quadriceps strength (MVC), symptom scores at the end of CET and exercise intensity during CET (heart rate at the end of CET to heart rate at peak incremental exercise ratio [HRCET/HRpeak]) were analyzed as potential variables influencing Tend. Results Wpeak, peak, VT, MVC, leg fatigue at end of CET, and HRCET/HRpeak were lower in group 1 than in group 2 or 3 (p≤0.05). VT and leg fatigue at end of CET independently predicted Tend in multiple regression analysis (r = 0.50, p = 0.001). Conclusion Tend was independently related to the aerobic fitness and to tolerance to leg fatigue at the end of exercise. A large fraction of the variability in Tend was not explained by the physiological parameters assessed in the present study. Individualization of exercise intensity during CET should help in reducing variations in Tend among patients with COPD. PMID:21386991

  5. All-semiconductor high-speed akinetic swept-source for OCT

    NASA Astrophysics Data System (ADS)

    Minneman, Michael P.; Ensher, Jason; Crawford, Michael; Derickson, Dennis

    2011-12-01

    A novel swept-wavelength laser for optical coherence tomography (OCT) using a monolithic semiconductor device with no moving parts is presented. The laser is a Vernier-Tuned Distributed Bragg Reflector (VT-DBR) structure exhibiting a single longitudinal mode. All-electronic wavelength tuning is achieved at a 200 kHz sweep repetition rate, 20 mW output power, over 100 nm sweep width and coherence length longer than 40 mm. OCT point-spread functions with 45- 55 dB dynamic range are demonstrated; lasers at 1550 nm, and now 1310 nm, have been developed. Because the laser's long-term tuning stability allows for electronic sample trigger generation at equal k-space intervals (electronic k-clock), the laser does not need an external optical k-clock for measurement interferometer sampling. The non-resonant, allelectronic tuning allows for continuously adjustable sweep repetition rates from mHz to 100s of kHz. Repetition rate duty cycles are continuously adjustable from single-trigger sweeps to over 99% duty cycle. The source includes a monolithically integrated power leveling feature allowing flat or Gaussian power vs. wavelength profiles. Laser fabrication is based on reliable semiconductor wafer-scale processes, leading to low and rapidly decreasing cost of manufacture.

  6. Effects of daily activity recorded by pedometer on peak oxygen consumption (VO2peak), ventilatory threshold and leg extension power in 30- to 69-year-old Japanese without exercise habit.

    PubMed

    Zhang, Jian-Guo; Ohta, Toshiki; Ishikawa-Takata, Kazuko; Tabata, Izumi; Miyashita, Mitsumasa

    2003-09-01

    The relationships among walk steps, exercise habits and peak oxygen consumption (VO2peak), ventilatory threshold (VT) and leg extension power (LEP) were examined in 709 apparently healthy Japanese subjects (male 372, female 337) aged 30-69 years. Walk steps were evaluated using a pedometer. VO2peak and VT were assessed by a cycle ergometer test, while LEP was measured with an isokinetic leg extension system (Combi, Anaero Press 3500, Japan). Subjects who participated in exercise three times or more a week demonstrated significantly greater VO2peak and VT when compared with subjects without exercise habits. When a separate analysis was conducted on subjects who exercised fewer than three times per week, we found that the subgroup with the highest number of walk steps showed significantly greater VT in all male subjects and female subjects aged 30-49 years, but a significantly greater VO2peak only in females aged 30-49 years, when compared to the subgroup with the fewest walk steps. These results suggest that although some people exercise less than three times a week, if they are quite active in daily life, such activities might also confer benefits upon their fitness.

  7. Flux dynamics and magnetovoltage measurements in a macroscopic cylindrical hole drilled in BSCCO

    NASA Astrophysics Data System (ADS)

    Yetiş, H.; Altinkok, A.; Olutaş, M.; Kiliç, A.; Kiliç, K.

    2007-10-01

    Slow transport relaxation measurements (V-t curves) and magnetovoltage measurements (V-H curves) were carried out in a polycrystalline sample of Bi1.7Pb0.3Sr2Ca2Cu3Ox (BSCCO) with a macroscopic cylindrically drilled hole (CH). The time evolution of quenched state in V-t curves was interpreted in terms of enhancement of the superconducting order parameter and the relaxation of moving entity. Upon cycling of the external magnetic field with different sweep rates, unusual counter clockwise hysteresis effects and asymmetry in V-H curves are observed in BSCCO sample with CH, which can also be correlated to the trapping of the macroscopic flux bundles in CH.

  8. Comparison of Ventilatory Measures and 20 km Time Trial Performance.

    PubMed

    Peveler, Willard W; Shew, Brandy; Johnson, Samantha; Sanders, Gabe; Kollock, Roger

    2017-01-01

    Performance threshold measures are used to predict cycling performance. Previous research has focused on long time trials (≥ 40 km) using power at ventilatory threshold and respiratory threshold to estimate time trial performance. As intensity greatly differs during shorter time trails applying findings from longer time trials may not be appropriate. The use of heart rate measures to determine 20 km time trial performance has yet to be examined. The purpose of this study was to determine the effectiveness of heart rate measures at ventilatory threshold (VE/VO 2 Plotted and VT determined by software) and respiratory threshold (RER of 0.95, 1.00, and 1.05) to predict 20 km time trial performance. Eighteen cyclists completed a VO 2max protocol and two 20 km time trials. Average heart rates from 20 km time trials were compared with heart rates from performance threshold measures (VT plotted, VT software, and an RER at 0.95, 1.00, and 1.05) using repeated measures ANOVA. Significance was set a priori at P ≤ 0.05. The only measure not found to be significantly different in relation to time trial performance was HR at an RER of 1.00 (166.61±12.70 bpm vs. 165.89 ± 9.56 bpm, p = .671). VT plotting and VT determined by software were found to underestimate time trial performance by 3% and 8% respectively. From these findings it is recommended to use heart rate at a RER of 1.00 in order to determine 20 km time trial intensity.

  9. Hole pairing and ground state properties of high-Tc superconductivity within the t-t'-J-V model

    NASA Astrophysics Data System (ADS)

    Roy, Krishanu; Pal, Papiya; Nath, Subhadip; Ghosh, Nanda Kumar

    2018-04-01

    The t-t'-J-V model, one of the realistic models for studying high-Tc cuprates, has been investigated to explore the hole pairing and other ground state properties using exact diagonalization (ED) technique with 2 holes in a small 8-site cluster. The role of next-nearest-neighbor (NNN) hopping and nearest-neighbor (NN) Coulomb repulsion has been considered. It appears that qualitative behavior of the ground state energies of an 8-site and 16- or 18-site cluster is similar. Results show that a small short-ranged antiferromagnetic (AF) correlation exists in the 2 hole case which is favored by large V/t. A superconducting phase emerges at 0 ≤ V/t ≤ 4J. Hole-hole correlation calculation also suggests that the two holes of the pair are either at |i - j| = 1 or √2. Negative t'/t suppresses the possibility of pairing of holes. Though s-wave pairing susceptibility is dominant, pairing correlation length calculation indicates that the long range pairing, which is suitable for superconductivity, is in the d-wave channel. Both s- and d-wave pairing susceptibility gets suppressed by V/t while d-(s-) wave susceptibility gets favored (suppressed) by t'/t. The charge gap shows a gapped behavior while a spin-gapless region exists at small V/t for finite t'/t.

  10. Path scheduling for multiple mobile actors in wireless sensor network

    NASA Astrophysics Data System (ADS)

    Trapasiya, Samir D.; Soni, Himanshu B.

    2017-05-01

    In wireless sensor network (WSN), energy is the main constraint. In this work we have addressed this issue for single as well as multiple mobile sensor actor network. In this work, we have proposed Rendezvous Point Selection Scheme (RPSS) in which Rendezvous Nodes are selected by set covering problem approach and from that, Rendezvous Points are selected in a way to reduce the tour length. The mobile actors tour is scheduled to pass through those Rendezvous Points as per Travelling Salesman Problem (TSP). We have also proposed novel rendezvous node rotation scheme for fair utilisation of all the nodes. We have compared RPSS with Stationery Actor scheme as well as RD-VT, RD-VT-SMT and WRP-SMT for performance metrics like energy consumption, network lifetime, route length and found the better outcome in all the cases for single actor. We have also applied RPSS for multiple mobile actor case like Multi-Actor Single Depot (MASD) termination and Multi-Actor Multiple Depot (MAMD) termination and observed by extensive simulation that MAMD saves the network energy in optimised way and enhance network lifetime compared to all other schemes.

  11. Physiological Demands of Simulated Off-Road Cycling Competition

    PubMed Central

    Smekal, Gerhard; von Duvillard, Serge P.; Hörmandinger, Maximilian; Moll, Roland; Heller, Mario; Pokan, Rochus; Bacharach, David W.; LeMura, Linda M.; Arciero, Paul

    2015-01-01

    The purpose of the study was to measure the demands of off-road cycling via portable spirometry, leg-power output (PO), heart rate (HR) and blood lactate (BLa) concentration. Twenty-four male competitive cyclists (age: 29±7.2 yrs, height: 1.79 ± 0.05 m, body mass: 70.0 ± 4.9 kg, VO2peak: 64.9 ± 7.5 ml·kg-1·min-1) performed simulated mountain bike competitions (COMP) and laboratory tests (LabT). From LabT, we determined maximal workload and first and second ventilatory thresholds (VT1, VT2). A high-performance athlete (HPA) was used for comparison with three groups of subjects with different sport-specific performance levels. Load profiles of COMP were also investigated during uphill, flat and downhill cycling. During the COMP, athletes achieved a mean oxygen uptake (VO2COMP) of 57.0 ± 6.8 ml·kg-1·min-1 vs. 71.1 ml·kg-1·min-1 for the HPA. The POCOMP was 2.66±0.43 W·kg-1 and 3.52 W·kg-1 for the HPA. POCOMP, VO2COMP and HRCOMP were compared to corresponding variables at the VT2 of LabT. LabT variables correlated with racing time (RTCOMP) and POCOMP (p < 0.01 to <0.001; r-0.59 to -0.80). The VO2peak (LabT) accounted for 65% of variance of a single COMP test. VO2COMP, POCOMP and also endurance variables measured from LabTs were found as important determinants for cross-country performance. The high average VO2COMP indicates that a high aerobic capacity is a prerequisite for successful COMP. Findings derived from respiratory gas measures during COMPs might be useful when designing mountain bike specific training. Key points Cross- country cycling is characterized by high oxygen costs due to the high muscle mass simultaneously working to fulfill the demands of this kind of sports. Heart rate and blood lactate concentration measures are not sensitive enough to assess the energy requirements of COMP. Therefore, respiratory gas and power output measures are helpful to provide new information to physiological profile of cross- country cycling. An excellent cycling-specific capacity is a prerequisite for successful off-road cycling. Data determined from LabT might be utilized to describe semi-specific abilities of MB- athletes on a cycle ergometer, while data originating from COMP might be useful when designing a mountain bike specific training. PMID:26664277

  12. The development of rating of perceived exertion-based tests of physical working capacity.

    PubMed

    Mielke, Michelle; Housh, Terry J; Malek, Moh H; Beck, Travis W; Schmidt, Richard J; Johnson, Glen O

    2008-01-01

    The purpose of the present study was to use ratings of perceived exertion (RPE) from the Borg (6-20) and OMNI-Leg (0-10) scales to determine the Physical Working Capacity at the Borg and OMNI thresholds (PWC(BORG) and PWC(OMNI)). PWC(BORG) and PWC(OMNI) were compared with other fatigue thresholds determined from the measurement of heart rate (the Physical Working Capacity at the Heart Rate Threshold: PWC(HRT)), and oxygen consumption (the Physical Working Capacity at the Oxygen Consumption Threshold, PWC(VO2)), as well as the ventilatory threshold (VT). Fifteen men and women volunteers (mean age +/- SD = 22 +/- 1 years) performed an incremental test to exhaustion on an electronically braked ergometer for the determination of VO2 peak and VT. The subjects also performed 4 randomly ordered workbouts to exhaustion at different power outputs (ranging from 60 to 206W) for the determination of PWC(BORG), PWC(OMNI), PWC(HRT), and PWC(VO2). The results indicated that there were no significant mean differences among the fatigue thresholds: PWC(BORG) (mean +/- SD = 133 +/- 37W; 67 +/- 8% of VO2 peak), PWC(OMNI) (137 +/- 44W; 68 +/- 9% of VO2 peak), PWC(HRT) (135 +/- 36W; 68 +/- 8% of VO2 peak), PWC(VO2) (145 +/- 41W; 72 +/- 7% of VO2 peak) and VT (131 +/- 45W; 66 +/- 8% of VO2 peak). The results of this study indicated that the mathematical model used to estimate PWC(HRT) and PWC(VO2) can be applied to ratings of perceived exertion to determine PWC(BORG) and PWC(OMNI) during cycle ergometry. Salient features of the PWC(BORG) and PWC(OMNI) tests are that they are simple to administer and require the use of only an RPE scale, a stopwatch, and a cycle ergometer. Furthermore, the power outputs at the PWC(BORG) and PWC(OMNI) may be useful to estimate the VT noninvasively and without the need for expired gas analysis.

  13. Gymnasium-based unsupervised exercise maintains benefits in oxygen uptake kinetics obtained following supervised training in type 2 diabetes.

    PubMed

    Macananey, Oscar; O'Shea, Donal; Warmington, Stuart A; Green, Simon; Egaña, Mikel

    2012-08-01

    Supervised exercise (SE) in patients with type 2 diabetes improves oxygen uptake kinetics at the onset of exercise. Maintenance of these improvements, however, has not been examined when supervision is removed. We explored if potential improvements in oxygen uptake kinetics following a 12-week SE that combined aerobic and resistance training were maintained after a subsequent 12-week unsupervised exercise (UE). The involvement of cardiac output (CO) in these improvements was also tested. Nineteen volunteers with type 2 diabetes were recruited. Oxygen uptake kinetics and CO (inert gas rebreathing) responses to constant-load cycling at 50% ventilatory threshold (V(T)), 80% V(T), and mid-point between V(T) and peak workload (50% Δ) were examined at baseline (on 2 occasions) and following each 12-week training period. Participants decided to exercise at a local gymnasium during the UE. Thirteen subjects completed all the interventions. The time constant of phase 2 of oxygen uptake was significantly faster (p < 0.05) post-SE and post-UE compared with baseline at 50% V(T) (17.3 ± 10.7 s and 17.5 ± 5.9 s vs. 29.9 ± 10.7 s), 80% V(T) (18.9 ± 4.7 and 20.9 ± 8.4 vs. 34.3 ± 12.7s), and 50% Δ (20.4 ± 8.2 s and 20.2 ± 6.0 s vs. 27.6 ± 3.7 s). SE also induced faster heart rate kinetics at all 3 intensities and a larger increase in CO at 30 s in relation to 240 s at 80% V(T); and these responses were maintained post-UE. Unsupervised exercise maintained benefits in oxygen uptake kinetics obtained during a supervised exercise in subjects with diabetes, and these benefits were associated with a faster dynamic response of heart rate after training.

  14. High-intensity interval training and β-hydroxy-β-methylbutyric free acid improves aerobic power and metabolic thresholds.

    PubMed

    Robinson, Edward H; Stout, Jeffrey R; Miramonti, Amelia A; Fukuda, David H; Wang, Ran; Townsend, Jeremy R; Mangine, Gerald T; Fragala, Maren S; Hoffman, Jay R

    2014-01-01

    Previous research combining Calcium β-hydroxy-β-methylbutyrate (CaHMB) and running high-intensity interval training (HIIT) have shown positive effects on aerobic performance measures. The purpose of this study was to examine the effect of β-hydroxy-β-methylbutyric free acid (HMBFA) and cycle ergometry HIIT on maximal oxygen consumption (VO2peak), ventilatory threshold (VT), respiratory compensation point (RCP) and time to exhaustion (Tmax) in college-aged men and women. Thirty-four healthy men and women (Age: 22.7 ± 3.1 yrs ; VO2peak: 39.3 ± 5.0 ml · kg(-1) · min(-1)) volunteered to participate in this double-blind, placebo-controlled design study. All participants completed a series of tests prior to and following treatment. A peak oxygen consumption test was performed on a cycle ergometer to assess VO2peak, Tmax, VT, and RCP. Twenty-six participants were randomly assigned into either a placebo (PLA-HIIT) or 3 g per day of HMBFA (BetaTor™) (HMBFA-HIIT) group. Eight participants served as controls (CTL). Participants in the HIIT groups completed 12 HIIT (80-120% maximal workload) exercise sessions consisting of 5-6 bouts of a 2:1 minute cycling work to rest ratio protocol over a four-week period. Body composition was measured with dual energy x-ray absorptiometry (DEXA). Outcomes were assessed by ANCOVA with posttest means adjusted for pretest differences. The HMBFA-HIIT intervention showed significant (p < 0.05) gains in VO2peak, and VT, versus the CTL and PLA-HIIT group. Both PLA-HIIT and HMBFA-HIIT treatment groups demonstrated significant (p < 0.05) improvement over CTL for Tmax, and RCP with no significant difference between the treatment groups. There were no significant differences observed for any measures of body composition. An independent-samples t-test confirmed that there were no significant differences between the training volumes for the PLA-HIIT and HMBFA-HIIT groups. Our findings support the use of HIIT in combination with HMBFA to improve aerobic fitness in college age men and women. These data suggest that the addition of HMBFA supplementation may result in greater changes in VO2peak and VT than HIIT alone. The study was registered on ClinicalTrials.gov (ID NCT01941368).

  15. Respiratory system loop gain in normal men and women measured with proportional-assist ventilation.

    PubMed

    Wellman, Andrew; Malhotra, Atul; Fogel, Robert B; Edwards, Jill K; Schory, Karen; White, David P

    2003-01-01

    We hypothesized that increased chemical control instability (CCI) in men could partially explain the male predominance in obstructive sleep apnea (OSA). CCI was assessed by sequentially increasing respiratory control system loop gain (LG) with proportional-assist ventilation (PAV) in 10 men (age 24-48 yr) and 9 women (age 22-36 yr) until periodic breathing or awakening occurred. Women were studied in both the follicular and luteal phases of the menstrual cycle. The amount by which PAV amplified LG was quantified from the tidal volume amplification factor [(VtAF) assisted tidal volume/unassisted tidal volume]. LG was calculated as the inverse of the VtAF occurring at the assist level immediately preceding the emergence of periodic breathing (when LG x VtAF = 1). Only 1 of 10 men and 2 of 9 women developed periodic breathing with PAV. The rest were resistant to periodic breathing despite moderately high levels of PAV amplification. We conclude that LG is low in the majority of normal men and women and that higher volume amplification factors are needed to determine whether gender differences exist in this low range.

  16. Physiological and perceptual responses to incremental exercise testing in healthy men: effect of exercise test modality.

    PubMed

    Muscat, Kristina M; Kotrach, Houssam G; Wilkinson-Maitland, Courtney A; Schaeffer, Michele R; Mendonca, Cassandra T; Jensen, Dennis

    2015-11-01

    In a randomized cross-over study of 15 healthy men aged 20-30 years, we compared physiological and perceptual responses during treadmill and cycle exercise test protocols matched for increments in work rate - the source of increased locomotor muscle metabolic and contractile demands. The rates of O2 consumption and CO2 production were higher at the peak of treadmill versus cycle testing (p ≤ 0.05). Nevertheless, work rate, minute ventilation, tidal volume (VT), breathing frequency (fR), inspiratory capacity (IC), inspiratory reserve volume (IRV), tidal esophageal (Pes,tidal) and transdiaphragmatic pressure swings (Pdi,tidal), peak expiratory gastric pressures (Pga,peak), the root mean square of the diaphragm electromyogram (EMGdi,rms) expressed as a percentage of maximum EMGdi,rms (EMGdi,rms%max), and dyspnea ratings were similar at the peak of treadmill versus cycle testing (p > 0.05). Ratings of leg discomfort were higher at the peak of cycle versus treadmill exercise (p ≤ 0.05), even though peak O2 consumption was lower during cycling. Oxygen consumption, CO2 production, minute ventilation, fR, Pes,tidal, Pdi,tidal and Pga,peak were higher (p ≤ 0.05), while VT, IC, IRV, EMGdi,rms%max, and ratings of dyspnea and leg discomfort were similar (p > 0.05) at all or most submaximal work rates during treadmill versus cycle exercise. Our findings highlight important differences (and similarities) in physiological and perceptual responses at maximal and submaximal work rates during incremental treadmill and cycle exercise testing protocols. The lack of effect of exercise test modality on peak work rate advocates for the use of this readily available parameter to optimize training intensity determination, regardless of exercise training mode.

  17. Effects of Endurance Training at the Crossover Point in Women with Metabolic Syndrome.

    PubMed

    Borel, Benoit; Coquart, Jérémy; Boitel, Guillaume; Duhamel, Alain; Matran, Régis; Delsart, Pascal; Mounier-Vehier, Claire; Garcin, Murielle

    2015-11-01

    On the basis of theoretical evidence, intensity at the crossover point (COP) of substrate utilization could be considered as potential exercise intensity for metabolic syndrome (MetS). This study aimed to examine the effects of a training program at COP on exercise capacity parameters in women with MetS and to compare two metabolic indices (COP and the maximal fat oxidation rate point LIPOXmax®) with ventilatory threshold (VT). Nineteen women with MetS volunteered to perform a 12-wk training program on a cycle ergometer, with intensity corresponding to COP. Pre- and posttraining values of anthropometric and exercise capacity parameters were compared to determine the effects of exercise training. The pre-post training change of COP, LIPOXmax®, and VT were also investigated. After training, anthropometric parameters were significantly modified, with reduction of body mass (3.0% ± 3.0%, P < 0.001), fat mass (3.3% ± 3.4%, P < 0.001), and body mass index (3.2% ± 3.4%, P < 0.001). Exercise capacity was improved after the training program, with significant increase of maximal power output (25.0% ± 18.4%, P < 0.001) and maximal oxygen uptake (V˙O2max, 9.0% ± 11.2%; P < 0.01). Lastly, when expressed in terms of power output, COP, LIPOXmax®, and VT occurred at a similar exercise intensity, but the occurrence of these three indices is different when expressed in terms of oxygen uptake, HR, or RPE. This study highlights the effectiveness of a 12-wk training program at COP to improve physical fitness in women with MetS. The relations between metabolic indices and VT in terms of power output highlight the determination of VT from a shorter maximal exercise as a useful method for determining metabolic indices in MetS.

  18. Structure-dependent Pseudoreceptor Intracellular Traffic of Adamantyl Globotriaosyl Ceramide Mimics*

    PubMed Central

    Saito, Mitsumasa; Mylvaganum, Murugespillai; Tam, Patty; Novak, Anton; Binnington, Beth; Lingwood, Clifford

    2012-01-01

    The verotoxin (VT) (Shiga toxin) receptor globotriaosyl ceramide (Gb3), mediates VT1/VT2 retrograde transport to the endoplasmic reticulum (ER) for cytosolic A subunit access to inhibit protein synthesis. Adamantyl Gb3 is an amphipathic competitive inhibitor of VT1/VT2 Gb3 binding. However, Gb3-negative VT-resistant CHO/Jurkat cells incorporate adaGb3 to become VT1/VT2-sensitive. CarboxyadaGb3, urea-adaGb3, and hydroxyethyl adaGb3, preferentially bound by VT2, also mediate VT1/VT2 cytotoxicity. VT1/VT2 internalize to early endosomes but not to Golgi/ER. AdabisGb3 (two deacyl Gb3s linked to adamantane) protects against VT1/VT2 more effectively than adaGb3 without incorporating into Gb3-negative cells. AdaGb3 (but not hydroxyethyl adaGb3) incorporation into Gb3-positive Vero cells rendered punctate cell surface VT1/VT2 binding uniform and subverted subsequent Gb3-dependent retrograde transport to Golgi/ER to render cytotoxicity (reduced for VT1 but not VT2) brefeldin A-resistant. VT2-induced vacuolation was maintained in adaGb3-treated Vero cells, but vacuolar membrane VT2 was lost. AdaGb3 destabilized membrane cholesterol and reduced Gb3 cholesterol stabilization in phospholipid liposomes. Cholera toxin GM1-mediated Golgi/ER targeting was unaffected by adaGb3. We demonstrate the novel, lipid-dependent, pseudoreceptor function of Gb3 mimics and their structure-dependent modulation of endogenous intracellular Gb3 vesicular traffic. PMID:22418442

  19. Chronotropic and pressor effects of water ingestion at rest and in response to incremental dynamic exercise.

    PubMed

    Mendonca, Goncalo V; Teixeira, Micael S; Heffernan, Kevin S; Fernhall, Bo

    2013-06-01

    Ingestion of water attenuates the chronotropic response to submaximal exercise. However, it is not known whether this effect is equally manifested during dynamic exercise below and above the ventilatory threshold (VT). We explored the effects of water ingestion on the heart rate response to an incremental cycle-ergometer protocol. In a randomized fashion, 19 healthy adults (10 men and nine women, age 20.9 ± 1.8 years) ingested 50 and 500 ml of water before completing a cycle-ergometer protocol on two separate days. The heart rate and oxygen uptake ( ) responses to water ingestion were analysed both at rest and during exercise performed below and above the VT. The effects of water intake on brachial blood pressure were measured only at rest. Resting mean arterial pressure increased and resting heart rate decreased, but only after 500 ml of water (P < 0.05). Compared with that seen after 50 ml of water, the 500 ml volume elicited an overall decrease in submaximal heart rate (P < 0.05). In contrast, drinking 500 ml of water did not affect submaximal . The participants' maximal heart rate, maximal and VT were similar between conditions. Our results therefore indicate that, owing to its effects on submaximal heart rate over a broad spectrum of intensities, the drinking of water should be recognized as a potential confounder in cardiovascular exercise studies. However, by showing no differences between conditions for submaximal , they also suggest that the magnitude of heart rate reduction after drinking 500 ml of water may be of minimal physiological significance for exercise cardiorespiratory capacity.

  20. Nucleotide Sequences and Comparison of Two Large Conjugative Plasmids from Different Campylobacter species

    DTIC Science & Technology

    2004-01-01

    alleles have different predicted lengths, e.g. in pCC31, cpp46 starts with ATGATG whereas in pTet this gene starts with only one ATG; in ssb1 , cmgB7 and...homologues in plasmid pVT745 from Actinobacillus actinomycetemcomitans, and a single-stranded DNA-binding protein ssb1 that may coat the single-stranded

  1. Comparison of the influence of age on cycling efficiency and the energy cost of running in well-trained triathletes.

    PubMed

    Peiffer, Jeremiah; Abbiss, Chris R; Sultana, Frederic; Bernard, Thierry; Brisswalter, Jeanick

    2016-01-01

    Locomotive efficiency is cited as an important component to endurance performance; however, inconsistent observations of age-related changes in efficiency question its influence in the performance of masters athletes. This study examined locomotive efficiency in young and masters triathletes during both a run and cycle test. Twenty young (28.5 ± 2.6 years) and 20 masters (59.8 ± 1.3 years) triathletes completed an incremental cycling and running test to determine maximal aerobic consumption (VO2max) and the first ventilatory threshold (VT1). Participants then completed 10-min submaximal running and cycling tests at VT1 during which locomotive efficiency was calculated from expired ventilation. Additionally, body fat percentage was determined using skin-fold assessment. During the cycle and run, VO2max was lower in the masters (48.3 ± 5.4 and 49.6 ± 4.8 ml kg(-1) min(-1), respectively) compared with young (61.6 ± 5.7 and 62.4 ± 5.2 ml kg(-1) min(-1), respectively) cohort. Maximal running speed and the cycling power output corresponding to VO2max were also lower in the masters (15.1 ± 0.8 km h(-1) and 318.6 ± 26.0 W) compared with the young (19.5 ± 1.3 km h(-1) and 383.6 ± 35.0 W) cohort. Cycling efficiency was lower (-11.2%) in the masters compared with young cohort. Similar results were observed for the energy cost of running (+10.8%); however, when scaled to lean body mass, changes were more pronounced during the run (+22.1%). Within trained triathletes, ageing can influence efficiency in both the run and cycle discipline. While disregarded in the past, efficiency should be considered in research examining performance in ageing athletes.

  2. Does vibration training reduce the fall risk profile of frail older people admitted to a rehabilitation facility? A randomised controlled trial.

    PubMed

    Parsons, J; Mathieson, S; Jull, A; Parsons, M

    2016-01-01

    To determine the effect of Vibration Training (VT) on functional ability and falls risk among a group of frail older people admitted to an inpatient rehabilitation unit in a regional hospital in New Zealand. A randomized controlled trial of 56 participants (mean 82.01 years in the intervention group and 81.76 years in the control group). VT targeting lower limb muscles with a frequency 30-50 Hz occurred three times per week until discharge. Amplitude progressively increased from 2 to 5 mm to allow the programme to be individually tailored to the participant. The control group received usual care physiotherapy sessions. Outcome measures were: Physiological profile assessment (PPA); and Functional Independence measure (FIM) and Modified Falls Efficacy Scale (MFES). There was a statistically significant difference observed between the two groups in terms of FIM score (F = 5.09, p = 0.03) and MFES (F = 3.52, p = 0.007) but no difference was observed in terms of PPA scores (F = 0.96, p = 0.36). Among older people admitted to an inpatient rehabilitation facility there may be some beneficial effect to the use of VT in conjunction with usual care physiotherapy in terms of improved functional ability. The study design and the small dosage of VT provided may have precluded any change in falls risk among participants. Vibration training (VT) may assist in reducing the risk of falling among at risk older people. Current pressures on health systems (ageing population, reduced hospital length of stay) necessitate the development of innovative strategies to maximise the rehabilitation potential of older people. Among older people admitted to an inpatient rehabilitation facility there may be some beneficial effect to the use of vibration training in conjunction with usual care physiotherapy in terms of improved functional ability.

  3. Mechanical ventilatory constraints during incremental cycle exercise in human pregnancy: implications for respiratory sensation

    PubMed Central

    Jensen, Dennis; Webb, Katherine A; Davies, Gregory A L; O'Donnell, Denis E

    2008-01-01

    The aim of this study was to identify the physiological mechanisms of exertional respiratory discomfort (breathlessness) in pregnancy by comparing ventilatory (breathing pattern, airway function, operating lung volumes, oesophageal pressure (Poes)-derived indices of respiratory mechanics) and perceptual (breathlessness intensity) responses to incremental cycle exercise in 15 young, healthy women in the third trimester (TM3; between 34 and 38 weeks gestation) and again 4–5 months postpartum (PP). During pregnancy, resting inspiratory capacity (IC) increased (P < 0.01) and end-expiratory lung volume decreased (P < 0.001), with no associated change in total lung capacity (TLC) or static respiratory muscle strength. This permitted greater tidal volume (VT) expansion throughout exercise in TM3, while preserving the relationship between contractile respiratory muscle effort (tidal Poes swing expressed as a percentage of maximum inspiratory pressure (PImax)) and thoracic volume displacement (VT expressed as a percentage of vital capacity) and between breathlessness and ventilation (V̇E). At the highest equivalent work rate (HEWR = 128 ± 5 W) in TM3 compared with PP: V̇E, tidal Poes/PImax and breathlessness intensity ratings increased by 10.2 l min−1 (P < 0.001), 8.8%PImax (P < 0.05) and 0.9 Borg units (P < 0.05), respectively. Pulmonary resistance was not increased at rest or during exercise at the HEWR in TM3, despite marked increases in mean tidal inspiratory and expiratory flow rates, suggesting increased bronchodilatation. Dynamic mechanical constraints on VT expansion (P < 0.05) with associated increased breathlessness intensity ratings (P < 0.05) were observed near peak exercise in TM3 compared with PP. In conclusion: (1) pregnancy-induced increases in exertional breathlessness reflected the normal awareness of increased V̇E and contractile respiratory muscle effort; (2) mechanical adaptations of the respiratory system, including recruitment of resting IC and increased bronchodilatation, accommodated the increased VT while preserving effort–displacement and breathlessness–V̇E relationships; and (3) dynamic mechanical ventilatory constraints contributed to respiratory discomfort near the limits of tolerance in late gestation. PMID:18687714

  4. High-intensity interval training and β-hydroxy-β-methylbutyric free acid improves aerobic power and metabolic thresholds

    PubMed Central

    2014-01-01

    Background Previous research combining Calcium β-hydroxy-β-methylbutyrate (CaHMB) and running high-intensity interval training (HIIT) have shown positive effects on aerobic performance measures. The purpose of this study was to examine the effect of β-hydroxy-β-methylbutyric free acid (HMBFA) and cycle ergometry HIIT on maximal oxygen consumption (VO2peak), ventilatory threshold (VT), respiratory compensation point (RCP) and time to exhaustion (Tmax) in college-aged men and women. Methods Thirty-four healthy men and women (Age: 22.7 ± 3.1 yrs ; VO2peak: 39.3 ± 5.0 ml · kg-1 · min-1) volunteered to participate in this double-blind, placebo-controlled design study. All participants completed a series of tests prior to and following treatment. A peak oxygen consumption test was performed on a cycle ergometer to assess VO2peak, Tmax, VT, and RCP. Twenty-six participants were randomly assigned into either a placebo (PLA-HIIT) or 3 g per day of HMBFA (BetaTor™) (HMBFA-HIIT) group. Eight participants served as controls (CTL). Participants in the HIIT groups completed 12 HIIT (80-120% maximal workload) exercise sessions consisting of 5–6 bouts of a 2:1 minute cycling work to rest ratio protocol over a four-week period. Body composition was measured with dual energy x-ray absorptiometry (DEXA). Outcomes were assessed by ANCOVA with posttest means adjusted for pretest differences. Results The HMBFA-HIIT intervention showed significant (p < 0.05) gains in VO2peak, and VT, versus the CTL and PLA-HIIT group. Both PLA-HIIT and HMBFA-HIIT treatment groups demonstrated significant (p < 0.05) improvement over CTL for Tmax, and RCP with no significant difference between the treatment groups. There were no significant differences observed for any measures of body composition. An independent-samples t-test confirmed that there were no significant differences between the training volumes for the PLA-HIIT and HMBFA-HIIT groups. Conclusions Our findings support the use of HIIT in combination with HMBFA to improve aerobic fitness in college age men and women. These data suggest that the addition of HMBFA supplementation may result in greater changes in VO2peak and VT than HIIT alone. Study registration The study was registered on ClinicalTrials.gov (ID NCT01941368). PMID:24782684

  5. Fungal CYP51 Inhibitors VT-1161 and VT-1129 Exhibit Strong In Vitro Activity against Candida glabrata and C. krusei Isolates Clinically Resistant to Azole and Echinocandin Antifungal Compounds.

    PubMed

    Schell, W A; Jones, A M; Garvey, E P; Hoekstra, W J; Schotzinger, R J; Alexander, B D

    2017-03-01

    The in vitro activities of fungal CYP51 inhibitors VT-1161 and VT-1129 were determined for Candida glabrata ( n = 34) and C. krusei ( n = 50). C. glabrata isolates were screened for FKS gene mutations. All isolates were resistant clinically and/or in vitro to at least one standard antifungal compound. VT-1161 and VT-1129 MICs for all isolates were at least 5-fold below achievable human plasma levels for VT-1161. VT-1161 and VT-1129 are promising for the treatment of resistant C. glabrata and C. krusei infections. Copyright © 2017 American Society for Microbiology.

  6. Transient Outward K+ Current (Ito) Underlies the Right Ventricular Initiation of Polymorphic Ventricular Tachycardia in a Transgenic Rabbit Model of Long-QT Syndrome Type 1.

    PubMed

    Choi, Bum-Rak; Li, Weiyan; Terentyev, Dmitry; Kabakov, Anatoli Y; Zhong, Mingwang; Rees, Colin M; Terentyeva, Radmila; Kim, Tae Yun; Qu, Zhilin; Peng, Xuwen; Karma, Alain; Koren, Gideon

    2018-06-01

    Sudden death in long-QT syndrome type 1 (LQT1), an inherited disease caused by loss-of-function mutations in KCNQ1, is triggered by early afterdepolarizations (EADs) that initiate polymorphic ventricular tachycardia (pVT). We investigated ionic mechanisms that underlie pVT in LQT1 using a transgenic rabbit model of LQT1. Optical mapping, cellular patch clamping, and computer modeling were used to elucidate the mechanisms of EADs in transgenic LQT1 rabbits. The results showed that shorter action potential duration in the right ventricle (RV) was associated with focal activity during pVT initiation. RV cardiomyocytes demonstrated higher incidence of EADs under 50 nmol/L isoproterenol. Voltage-clamp studies revealed that the transient outward potassium current (I to ) magnitude was 28% greater in RV associated with KChiP2 but with no differences in terms of calcium-cycling kinetics and other sarcolemmal currents. Perfusing with the I to blocker 4-aminopyridine changed the initial focal sites of pVT from the RV to the left ventricle, corroborating the role of I to in pVT initiation. Computer modeling showed that EADs occur preferentially in the RV because of the larger conductance of the slow-inactivating component of I to , which repolarizes the membrane potential sufficiently rapidly to allow reactivation of I Ca,L before I Kr has had sufficient time to activate. I to heterogeneity creates both triggers and an arrhythmogenic substrate in LQT1. In the absence of I Ks , I to interactions with I Ca,L and I Kr promote EADs in the RV while prolonging action potential duration in the left ventricle. This heterogeneity of action potential enhances dispersion of refractoriness and facilitates conduction blocks that initiate pVTs. © 2018 American Heart Association, Inc.

  7. Effect of CO₂ on the ventilatory sensitivity to rising body temperature during exercise.

    PubMed

    Hayashi, Keiji; Honda, Yasushi; Miyakawa, Natsuki; Fujii, Naoto; Ichinose, Masashi; Koga, Shunsaku; Kondo, Narihiko; Nishiyasu, Takeshi

    2011-05-01

    We examined the degree to which ventilatory sensitivity to rising body temperature (the slope of the regression line relating ventilation and body temperature) is altered by restoration of arterial PCO(2) to the eucapnic level during prolonged exercise in the heat. Thirteen subjects exercised for ~60 min on a cycle ergometer at 50% of peak O(2) uptake with and without inhalation of CO(2)-enriched air. Subjects began breathing CO(2)-enriched air at the point that end-tidal Pco(2) started to decline. Esophageal temperature (T(es)), minute ventilation (V(E)), tidal volume (V(T)), respiratory frequency (f(R)), respiratory gases, middle cerebral artery blood velocity, and arterial blood pressure were recorded continuously. When V(E), V(T), f(R), and ventilatory equivalents for O(2) uptake (V(E)/VO(2)) and CO(2) output (V(E)/VCO(2)) were plotted against changes in T(es) from the start of the CO(2)-enriched air inhalation (ΔT(es)), the slopes of the regression lines relating V(E), V(T), V(E)/VO(2), and V(E)/VCO(2) to ΔT(es) (ventilatory sensitivity to rising body temperature) were significantly greater when subjects breathed CO(2)-enriched air than when they breathed room air (V(E): 19.8 ± 10.3 vs. 8.9 ± 6.7 l·min(-1)·°C(-1), V(T): 18 ± 120 vs. -81 ± 92 ml/°C; V(E)/VO(2): 7.4 ± 5.5 vs. 2.6 ± 2.3 units/°C, and V(E)/VCO(2): 7.6 ± 6.6 vs. 3.4 ± 2.8 units/°C). The increase in Ve was accompanied by increases in V(T) and f(R). These results suggest that restoration of arterial PCO(2) to nearly eucapnic levels increases ventilatory sensitivity to rising body temperature by around threefold.

  8. CT volumetry can potentially predict the local stage for gastric cancer after chemotherapy

    PubMed Central

    Wang, Zhi-Cong; Wang, Chen; Ding, Ying; Ji, Yuan; Zeng, Meng-Su; Rao, Sheng-Xiang

    2017-01-01

    PURPOSE We aimed to evaluate the value of CT tumor volumetry for predicting T and N stages of gastric cancer after chemotherapy, with pathologic results as the reference standard. METHODS This study retrospectively evaluated 42 patients diagnosed with gastric cancer, who underwent chemotherapy followed by surgery. Pre- and post-treatment CT tumor volumes (VT) were measured in portal venous phase and volume reduction ratios were calculated. Correlations between pre- and post-treatment VT, reduction ratio, and pathologic stages were analyzed. Receiver operator characteristic (ROC) analyses were also performed to assess diagnostic performance for prediction of downstaging to T0–2 stage and N0 stage. RESULTS Pretreatment VT, post-treatment VT, and VT reduction ratio were significantly correlated with T stage (rs=0.329, rs=0.546, rs= −0.422, respectively). Post-treatment VT and VT reduction ratio were significantly correlated with N stage (rs=0.442 and rs= −0.376, respectively). Pretreatment VT, post-treatment VT, and VT reduction ratio were significantly different between T0–2 and T3,4 stage tumors (P = 0.05, P < 0.001, and P = 0.002, respectively). The differences between N0 and ≥N1 groups were also statistically significant (P = 0.005 for post-treatment VT, P = 0.016 for VT reduction ratio, respectively). The area under the ROC curve (AUC) for identification of T0–2 groups was 0.70 for pretreatment VT, 0.88 for post-treatment VT, and 0.82 for VT reduction ratio, respectively. AUC was 0.78 for post-treatment VT and 0.74 for VT reduction ratio for identification of N0 groups. CONCLUSION CT tumor volumetry, particularly post-treatment measurement of VT, is potentially valuable for predicting histopathologic T and N stages after chemotherapy in patients with gastric cancer. PMID:28703101

  9. Science Library of Test Items. Volume Twelve. Mastery Testing Programme. [Mastery Tests Series 4.] Tests M39-M50.

    ERIC Educational Resources Information Center

    New South Wales Dept. of Education, Sydney (Australia).

    As part of a series of tests to measure mastery of specific skills in the natural sciences, copies of tests 39 through 50 include: (39) using a code; (40) naming the parts of a microscope; (41) calculating density and predicting flotation; (42) estimating metric length; (43) using SI symbols; (44) using s=vt; (45) applying a novel theory; (46)…

  10. Prognostic value of respiratory quotients in severe polytrauma patients with nutritional support.

    PubMed

    Patkova, Anna; Joskova, Vera; Havel, Eduard; Najpaverova, Simona; Uramova, Daniela; Kovarik, Miroslav; Zadak, Zdenek; Hronek, Miloslav

    2018-05-01

    The association between energy metabolism and prognosis in polytrauma patients has not yet been defined. The aim of this study was to describe energy metabolism and analyze the prognostic value of respiratory quotient (RQ) and nonprotein respiratory quotient (npRQ) in fasting polytrauma patients (fPP) and polytrauma patients with nutritional support (nsPP). Twenty-two polytrauma patients (before and after parenteral nutrition administration) and 22 healthy controls (after overnight fasting) were examined on day 4 (median) after admission to the intensive care unit. To evaluate energy expenditure in nsPP and resting energy expenditure in fPP and controls with RQ and npRQ in all groups, we used indirect calorimetry. With regression analysis, the descriptive models of intensive care unit (ICU) length of stay (LOS) and mechanical ventilation time (VT) were derived. RQ and npRQ were significantly lower in fPP than in controls (P < 0.05 and P < 0.01, respectively) and in nsPP (P < 0.05). In nsPP, relationships between RQ or npRQ and the ICU LOS or mechanical VT were demonstrated (P < 0.0001, r = -0.78 for RQ and VT; P < 0.0001, r = -0.78 for npRQ and VT; P < 0.001, r = -0.69 for RQ and LOS; P < 0.001, r = -0.72 for npRQ and LOS). RQ and npRQ parameters measured by indirect calorimetry in polytrauma patients with parenteral nutrition on the fourth day of ICU stay related to clinical outcomes such as duration of mechanical ventilation and ICU LOS. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Graphics Software For VT Terminals

    NASA Technical Reports Server (NTRS)

    Wang, Caroline

    1991-01-01

    VTGRAPH graphics software tool for DEC/VT computer terminal or terminals compatible with it, widely used by government and industry. Callable in FORTRAN or C language, library program enabling user to cope with many computer environments in which VT terminals used for window management and graphic systems. Provides PLOT10-like package plus color or shade capability for VT240, VT241, and VT300 terminals. User can easily design more-friendly user-interface programs and design PLOT10 programs on VT terminals with different computer systems. Requires ReGis graphics set terminal and FORTRAN compiler.

  12. Prediction and prognosis of ventricular tachycardia recurrence after catheter ablation with remote magnetic navigation for electrical storm in patients with ischemic cardiomyopathy.

    PubMed

    Jin, Qi; Jacobsen, Peter Karl; Pehrson, Steen; Chen, Xu

    2017-11-01

    Ventricular tachycardia (VT) recurrence after catheter ablation for electrical storm is commonly seen in patients with ischemic cardiomyopathy (ICM). We hypothesized that VT recurrence can be predicted and be related to the all-cause death after VT storm ablation guided by remote magnetic navigation (RMN) in patients with ICM. A total of 54 ICM patients (87% male; mean age, 65 ± 7.1 years) presenting with VT storm undergoing acute ablation using RMN were enrolled. Acute complete ablation success was defined as noninducibility of any sustained monomorphic VT at the end of the procedure. Early VT recurrence was defined as the occurrence of sustained VT within 1 month after the first ablation. After a mean follow-up of 17.1 months, 27 patients (50%) had freedom from VT recurrence. Sustained VT recurred in 12 patients (22%) within 1 month following the first ablation. In univariate analysis, VT recurrence was associated with incomplete procedural success (hazard ratio [HR]: 6.25, 95% confidence interval [CI]: 1.20-32.47, P = 0.029), lack of amiodarone usage before ablation (HR: 4.71, 95% CI: 1.12-19.7, P = 0.034), and a longer procedural time (HR: 1.023, 95% CI: 1.00-1.05, P = 0.05). The mortality of patients with early VT recurrence was higher than that of patients without recurrence (P < 0.01). Inducibility of any VT at the end of procedure for VT storm guided by RMN is the strongest predictor of VT recurrence. ICM patients who have early recurrences after VT storm ablation are at high risk of all-cause death. © 2017 Wiley Periodicals, Inc.

  13. Objectivity and validity of EMG method in estimating anaerobic threshold.

    PubMed

    Kang, S-K; Kim, J; Kwon, M; Eom, H

    2014-08-01

    The purposes of this study were to verify and compare the performances of anaerobic threshold (AT) point estimates among different filtering intervals (9, 15, 20, 25, 30 s) and to investigate the interrelationships of AT point estimates obtained by ventilatory threshold (VT) and muscle fatigue thresholds using electromyographic (EMG) activity during incremental exercise on a cycle ergometer. 69 untrained male university students, yet pursuing regular exercise voluntarily participated in this study. The incremental exercise protocol was applied with a consistent stepwise increase in power output of 20 watts per minute until exhaustion. AT point was also estimated in the same manner using V-slope program with gas exchange parameters. In general, the estimated values of AT point-time computed by EMG method were more consistent across 5 filtering intervals and demonstrated higher correlations among themselves when compared with those values obtained by VT method. The results found in the present study suggest that the EMG signals could be used as an alternative or a new option in estimating AT point. Also the proposed computing procedure implemented in Matlab for the analysis of EMG signals appeared to be valid and reliable as it produced nearly identical values and high correlations with VT estimates. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Histopathology of tympanic membranes from patients with ventilation tubes.

    PubMed

    Oktay, Mehmet Faruk; Tansuker, Hasan Deniz; Fukushima, Hisaki; Paparella, Michael M; Schachern, Patricia A; Cureoglu, Sebahattin

    2018-06-01

    To evaluate the histopathologic changes in tympanic membranes (TMs) with ventilation tubes (VTs). In this retrospective human temporal bone study our overall study group included 4 subgroups of TMs from deceased donors as follows: 24 with a history of VT insertion for chronic otitis media with effusion (COME-VT); 5 with a history of VT insertion for Meniere's disease (MD-VT); 33 without a history of VT insertion for chronic otitis media with effusion (COME); and 14 without a history of VT insertion for Meniere's disease (MD). We classified the extent of migration of the outer keratinized squamous epithelium onto the inner surface of TM perforations and noted the presence and location of tympanosclerosis, of atrophy, of perforation, and/or of cholesteatoma formation. Tympanosclerosis occurred in 14/24 TMs in the COME-VT subgroup; 2/5, MD-VT; 7/33, COME; and 0/14, MD. The VT insertion site was mostly in the anteroinferior (63%) quadrant of the TM; tympanosclerosis occurred more frequently in the posteroinferior (42%) and posterosuperior (33%) quadrants. We found no significant correlation between the location of tympanosclerosis and the VT insertion site (P>0.05). Atrophy occurred in 7/24 TMs in the COME-VT subgroup; 3/5, MD-VT; 8/33, COME; and 2/14, MD. We found no significant correlation between the location of atrophy and the VT insertion site; however, atrophy was located mostly in the anteroinferior quadrant (one of the most common VT insertion sites) of the TM. Regarding the ingrowth of keratinized epithelium, the mucocutanous junction was detected at any point at the inner surface of the TM in 50% of the specimens. We observed intratympanic cholesteatoma formation in 2/24 TMs in the COME-VT subgroup. TM changes due to VT insertion are more common than previously realized. Meticulous otomicroscopic evaluation of the TM is necessary during tympanomastoidectomies in order to prevent the intratympanic inclusion pearls and squamous epithelial ingrowth to prevent any further cholesteatoma formation. Copyright © 2017. Published by Elsevier B.V.

  15. Yolk proteins during ovary and egg development of mature female freshwater crayfish (Cherax quadricarinatus).

    PubMed

    Serrano-Pinto, Vania; Vazquez-Boucard, Celia; Villarreal-Colmenares, Humberto

    2003-01-01

    Vitellins from ovaries and eggs at different stages of development in freshwater crayfish (Cherax quadricarinatus) were examined by chromatography, PAGE and SDS-PAGE. With these methods, two forms of vitellin (Vt1 and Vt2) were observed in ovaries and eggs (stages I and V). In ovaries in secondary vitellogenesis, native molecular mass was 470 (Vt1) and 440 (Vt2) kDa. The electrophoretic pattern of the eggs proved to be more complex. The protein molecular mass depend on the development stage of the egg: stage I, 650 kDa (Vt1) and 440 kDa (Vt2); stage V, 390 kDa (Vt1) and 340 kDa (Vt2). The identified vitellins appear to be lipo-glycocarotenoprotein. A similar vitellin polypeptide composition was observed in the two forms of vitellin from ovaries and eggs in stage V. In ovaries the SDS-PAGE analysis showed four subunits with molecular weights of approximately 180, 120, 95 and 80 kDa (Vt1 and Vt2). The polypeptide composition in the two forms of vitellins in stage I and stage III eggs were different at 195, 190, 130 and 110 kDa (Vt1) and 116 and 107 kDa (Vt2). On the other hand, in stage V eggs, 110, 95, 87 and 75 kDa (Vt1 and Vt2) were identified. Two antibodies (Ab1 and Ab2) were prepared against the purified proteins of stage V eggs and their specificity was demonstrated by radial immunoprecipitation, and Western blotting analysis. Two forms of vitellins were also found in stage V eggs after chromatography on Sepharose CL-2B column and hydroxylapatite and polyacrylamide gel electrophoresis.

  16. VT-1161 protects mice against oropharyngeal candidiasis caused by fluconazole-susceptible and -resistant Candida albicans

    PubMed Central

    Break, Timothy J; Desai, Jigar V; Ferre, Elise M N; Henderson, Christina; Zelazny, Adrian M; Siebenlist, Ulrich; Hoekstra, William J; Schotzinger, Robert J; Garvey, Edward P; Lionakis, Michail S

    2018-01-01

    Abstract Background Candida albicans, the most common human fungal pathogen, causes chronic mucosal infections in patients with inborn errors of IL-17 immunity that rely heavily on chronic, often lifelong, azole antifungal agents for treatment. However, a rise in azole resistance has predicated a need for developing new antifungal drugs. Objectives To test the in vitro and in vivo efficacy of VT-1161 and VT-1129 in the treatment of oropharyngeal candidiasis with azole-susceptible or -resistant C. albicans strains. Methods MICs of VT-1161, VT-1129 and nine licensed antifungal drugs were determined for 31 Candida clinical isolates. The drug concentrations in mouse serum and tongues were measured following oral administration. IL-17-signalling-deficient Act1−/− mice were infected with fluconazole-susceptible or fluconazole-resistant C. albicans strains, and the amount of mucosal fungal burden was determined after fluconazole or VT-1161 treatment. Results Fourteen isolates (45%) were not fluconazole susceptible (MIC ≥4 mg/L). VT-1161 and VT-1129 showed significant in vitro activity against the majority of the 31 mucosal clinical isolates (MIC50 0.03 and 0.06 mg/L, respectively), including Candida glabrata (MIC50, 0.125 and 0.25 mg/L, respectively). After oral doses, VT-1161 and VT-1129 concentrations in mouse serum and tongues were well above their MIC50 values. VT-1161 was highly effective as treatment of both fluconazole-susceptible and -resistant oropharyngeal candidiasis in Act1−/− mice. Conclusions VT-1129 and VT-1161 exhibit significant in vitro activity against Candida strains, including fluconazole-resistant C. albicans and C. glabrata. VT-1161 administration in mice results in significant mucosal drug accumulation and eradicates infection caused by fluconazole-susceptible and -resistant Candida strains. PMID:29040636

  17. Combined Inoculation with Multiple Arbuscular Mycorrhizal Fungi Improves Growth, Nutrient Uptake and Photosynthesis in Cucumber Seedlings.

    PubMed

    Chen, Shuangchen; Zhao, Hongjiao; Zou, Chenchen; Li, Yongsheng; Chen, Yifei; Wang, Zhonghong; Jiang, Yan; Liu, Airong; Zhao, Puyan; Wang, Mengmeng; Ahammed, Golam J

    2017-01-01

    Mycorrhizal inoculation stimulates growth, photosynthesis and nutrient uptake in a wide range of host plants. However, the ultimate effects of arbuscular mycorrhyzal (AM) symbiosis vary with the plants and fungal species involved in the association. Therefore, identification of the appropriate combinations of AM fungi (AMF) that interact synergistically to improve their benefits is of high significance. Here, three AM fungal compositions namely VT ( Claroideoglomus sp., Funneliformis sp., Diversispora sp., Glomus sp., and Rhizophagus sp.) and BF ( Glomus intraradices , G. microageregatum BEG and G. Claroideum BEG 210), and Funneliformis mosseae (Fm) were investigated with respect to the growth, gas exchange parameters, enzymes activities in Calvin cycles and related gene expression in cucumber seedlings. The results showed that VT, BF and Fm could successfully colonize cucumber root to a different degree with the colonization rates 82.38, 74.65, and 70.32% at 46 days post inoculation, respectively. The plant height, stem diameter, dry weight, root to shoot ratio of cucumber seedlings inoculated with AMF increased significantly compared with the non-inoculated control. Moreover, AMF colonization greatly increased the root activity, chlorophyll content, net photosynthetic rate, light saturated rate of the CO 2 assimilation ( A sat), maximum carboxylation rate ( V cmax ) and maximum ribulose-1,5-bis-phosphate (RuBP) regeneration rate ( J max), which were increased by 52.81, 30.75, 58.76, 47.00, 69.15, and 65.53% when inoculated with VT, respectively. The activities of some key enzymes such RuBP carboxylase/oxygenase (RuBisCO), D-fructose-1,6-bisphosphatase (FBPase), D-fructose-6-phosphatase (F6P) and ribulose-5-phosphate kinase (Ru5PK), and related gene expression involved in the Calvin cycle including RCA , FBPase , FBPA , SBPase , rbcS and rbcL were upregulated by AMF colonization. AMF inoculation also improved macro- and micro nutrient contents such as N, P, K, S, Ca, Cu, Fe, Mn, Mg, and Zn in roots. Further analysis revealed that inoculation with VT had relatively better effect on growth of cucumber seedling followed by BF and Fm, indicating that AMF composition consisting of distant AMF species may have a better effect than a single or closely related AMF spp. This study advances the understanding of plant responses to different AM fungi toward development of strategies on AMF-promoted vegetable production.

  18. Normalization of respiratory sinus arrhythmia by factoring in tidal volume.

    PubMed

    Kobayashi, H

    1998-09-01

    The amplitude of respiratory sinus arrhythmia (RSA) was measured in eight healthy young male students with special reference to the effect of tidal volume (Vt). Under simultaneously controlled respiratory frequency and Vt, the heart rate variability (HRV) of the subjects was measured. While the respiratory frequency was adjusted to either 0.25 or 0.10 Hz, the Vt was controlled at 13 different volumes for each frequency. Linear relationships between RSA amplitude and Vt were observed and close correlations were obtained for 0.25 Hz compared with 0.10 Hz. However, regression equations showed a marked variation among subjects. Furthermore, RSA amplitude was related to vital capacity. Subjects who had lower vital capacity tended to show higher RSA amplitudes at the same Vt. Therefore, the ratio (% Vt) of Vt to vital capacity is a more effective index in normalizing RSA than raw tidal volume. From these results, we have proposed a normalized RSA (RSA amplitude/% Vt) as a new index of autonomic activity that provides a constant value regardless of Vt.

  19. Corrosion-resistant antifretting coating for the protection of blade locking pieces in GTE compressors and fans

    NASA Astrophysics Data System (ADS)

    Muboyadzhyan, S. A.; Gorlov, D. S.; Egorova, L. P.; Bulavintseva, E. E.

    2014-09-01

    The properties of a corrosion-resistant antifretting coating on EP866Sh steel and VT8M-1 titanium alloy samples are studied. The results of corrosion resistance, heat resistance, fretting resistance, long-term strength, and high-cycle fatigue tests and the results of physical metallurgy and metallographic investigations of the samples with the coating before and after the tests are presented.

  20. Arrhythmogenic Mechanisms in a Mouse Model of Catecholaminergic Polymorphic Ventricular Tachycardia

    PubMed Central

    Cerrone, Marina; Noujaim, Sami F.; Tolkacheva, Elena G.; Talkachou, Arkadzi; O’Connell, Ryan; Berenfeld, Omer; Anumonwo, Justus; Pandit, Sandeep V.; Vikstrom, Karen; Napolitano, Carlo; Priori, Silvia G.; Jalife, José

    2008-01-01

    Catecholaminergic polymorphic ventricular tachycardia (VT) is a lethal familial disease characterized by bidirectional VT, polymorphic VT, and ventricular fibrillation. Catecholaminergic polymorphic VT is caused by enhanced Ca2+ release through defective ryanodine receptor (RyR2) channels. We used epicardial and endocardial optical mapping, chemical subendocardial ablation with Lugol’s solution, and patch clamping in a knockin (RyR2/RyR2R4496C) mouse model to investigate the arrhythmogenic mechanisms in catecholaminergic polymorphic VT. In isolated hearts, spontaneous ventricular arrhythmias occurred in 54% of 13 RyR2/RyR2R4496C and in 9% of 11 wild-type (P=0.03) littermates perfused with Ca2+ and isoproterenol; 66% of 12 RyR2/RyR2R4496C and 20% of 10 wild-type hearts perfused with caffeine and epinephrine showed arrhythmias (P=0.04). Epicardial mapping showed that monomorphic VT, bidirectional VT, and polymorphic VT manifested as concentric epicardial breakthrough patterns, suggesting a focal origin in the His–Purkinje networks of either or both ventricles. Monomorphic VT was clearly unifocal, whereas bidirectional VT was bifocal. Polymorphic VT was initially multifocal but eventually became reentrant and degenerated into ventricular fibrillation. Endocardial mapping confirmed the Purkinje fiber origin of the focal arrhythmias. Chemical ablation of the right ventricular endocardial cavity with Lugol’s solution induced complete right bundle branch block and converted the bidirectional VT into monomorphic VT in 4 anesthetized RyR2/RyR2R4496C mice. Under current clamp, single Purkinje cells from RyR2/RyR2R4496C mouse hearts generated delayed afterdepolarization–induced triggered activity at lower frequencies and level of adrenergic stimulation than wild-type. Overall, the data demonstrate that the His–Purkinje system is an important source of focal arrhythmias in catecholaminergic polymorphic VT. PMID:17872467

  1. Blood Accessibility to Fibrin in Venous Thrombosis is Thrombus Age-Dependent and Predicts Fibrinolytic Efficacy: An In Vivo Fibrin Molecular Imaging Study

    PubMed Central

    Stein-Merlob, Ashley F.; Kessinger, Chase W.; Erdem, S. Sibel; Zelada, Henry; Hilderbrand, Scott A.; Lin, Charles P.; Tearney, Guillermo J.; Jaff, Michael R.; Reed, Guy L.; Henke, Peter K.; McCarthy, Jason R.; Jaffer, Farouc A.

    2015-01-01

    Fibrinolytic therapy of venous thromboembolism (VTE) is increasingly utilized, yet limited knowledge is available regarding in vivo mechanisms that govern fibrinolytic efficacy. In particular, it is unknown how age-dependent thrombus organization limits direct blood contact with fibrin, the target of blood-based fibrinolytic agents. Utilizing high-resolution in vivo optical molecular imaging with FTP11, a near-infrared fluorescence (NIRF) fibrin-specific reporter, here we investigated the in vivo interrelationships of blood accessibility to fibrin, thrombus age, thrombus neoendothelialization, and fibrinolysis in murine venous thrombosis (VT). In both stasis VT and non-stasis VT, NIRF microscopy showed that FTP11 fibrin binding was thrombus age-dependent. FTP11 localized to the luminal surface of early-stage VT, but only minimally to subacute VT (p<0.001). Transmission electron microscopy of early stage VT revealed direct blood cell contact with luminal fibrin-rich surfaces. In contrast, subacute VT exhibited an encasing CD31+ neoendothelial layer that limited blood cell contact with thrombus fibrin in both VT models. Next we developed a theranostic strategy to predict fibrinolytic efficacy based on the in vivo fibrin accessibility to blood NIRF signal. Mice with variably aged VT underwent FTP11 injection and intravital microscopy (IVM), followed by tissue plasminogen activator infusion to induce VT fibrinolysis. Fibrin molecular IVM revealed that early stage VT, but not subacute VT, bound FTP11 (p<0.05), and experienced higher rates of fibrinolysis and total fibrinolysis (p<0.05 vs. subacute VT). Before fibrinolysis, the baseline FTP11 NIRF signal predicted the net fibrinolysis at 60 minutes (p<0.001). Taken together, these data provide novel insights into the temporal evolution of VT and its susceptibility to therapeutic fibrinolysis. Fibrin molecular imaging may provide a theranostic strategy to identify venous thrombi amenable to fibrinolytic therapies. PMID:26516370

  2. Avoidance of Timeout from Response-Independent Food: Effects of Delivery Rate and Quality

    ERIC Educational Resources Information Center

    Richardson, Joseph V.; Baron, Alan

    2008-01-01

    In three experiments, a rat's lever presses could postpone timeouts from food pellets delivered on response-independent schedules. In Experiment 1, the pellets were delivered at variable-time (VT) rates ranging from VT 0.5 to VT 8 min. Experiment 2 replicated the VT 1 min and VT 8 min conditions of Experiment 1 with new subjects. Finally, subjects…

  3. Influence of humic acid on adsorption of Hg(II) by vermiculite.

    PubMed

    do Nascimento, Fernando Henrique; Masini, Jorge Cesar

    2014-10-01

    Geochemical mobility of Hg(II) species is strongly affected by the interactions of these compounds with naturally occurring adsorbents such as humic acids, clay minerals, oxides, etc. Interactions among these sorbents affect their affinity for Hg(II) and a full understanding of these processes is still lacking. The present work describes the influence of a humic acid (HA) sample on the adsorption of Hg(II) by vermiculite (VT). Adsorption isotherms were constructed to evaluate the affinity of Hg(II) by VT, HA, VT modified with humic acid (VT-HA), and VT-HA in presence of soluble humic acid (VT-HA + HA). All experiments were made at pH 6.0 ± 0.1 in 0.02 M NaNO3 and 25.0 ± 0.5 °C for initial Hg(II) concentrations from 1.0 to 100 μM. Determinations of Hg(II) were made by square wave voltammetry automated by sequential injection analysis, an approach that enables the determination of the free plus labile fractions of Hg(II) in HA suspensions without the need for laborious separation steps. The adsorption isotherms were fitted to Langmuir and Freundlich equations, showing that HA was the material with the higher adsorption capacity (537 ± 30 μmol g(-1)) in comparison with VT and VT-HA (44 ± 3 and 51 ± 11 μmol g(-1), respectively). Adsorption order was HA > VT-HA + HA > VT = VT-HA. At pH 6.0 the interaction of HA with VT is weak and only 14% of C initially added to the suspension was effectively retained by the mineral. Desorption of Hg(II) in acidic medium (0.05 M HCl) was higher in binary (VT-HA) and ternary (VT-HA + HA) systems in comparison with that of VT and HA alone, suggesting that interactions between VT and HA are facilitated in acidic medium, weakening the binding to Hg(II). Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. The association of statin therapy with the risk of recurrent venous thrombosis.

    PubMed

    Smith, N L; Harrington, L B; Blondon, M; Wiggins, K L; Floyd, J S; Sitlani, C M; McKnight, B; Larson, E B; Rosendaal, F R; Heckbert, S R; Psaty, B M

    2016-07-01

    Essentials A lowered risk of recurrent venous thrombosis (VT) with statin treatment is controversial. Among observational inception cohort of 2,798 adults with incident VT, 457 had recurrent VT. Time-to-event models with time-varying statin use and adjustment for potential confounders was used for analysis. Compared to nonuse, current statin use was associated with 26% lower risk of recurrent VT. Click to hear Prof. Büller's perspective on Anticoagulant Therapy in the Treatment of Venous Thromboembolism Background Meta-analyses of randomized controlled trials suggest that treatment with hydroxymethylglutaryl-coenzyme A reductase inhibitors (statins) lowers the risk of incident venous thrombosis (VT), particularly among those without prevalent clinical cardiovascular disease (CVD). Whether this is true for the prevention of recurrent VT is debated. We used an observational inception cohort to estimate the association of current statin use with the risk of recurrent VT. Methods and Results The study setting was a large healthcare organization with detailed medical record and pharmacy information at cohort entry and throughout follow-up. We followed 2798 subjects 18-89 years of age who experienced a validated incident VT between January 1, 2002, and December 31, 2010, for a first recurrent VT, validated by medical record review. During follow-up, 457 (16%) developed a first recurrent VT. In time-to-event models incorporating time-varying statin use and adjusting for potential confounders, current statin use was associated with a 26% lower risk of recurrent VT: hazard ratio 0.74, 95% confidence interval 0.59-0.94. Among cohort members free of CVD (n = 2134), current statin use was also associated with a lower risk (38%) of recurrent VT: hazard ratio 0.62, 95% confidence interval 0.45-0.85. We found similar results when restricting to new users of statins and in subgroups of different statin types and doses. Conclusions In a population-based cohort of subjects who had experienced an incident VT, statin use, compared with nonuse, was associated with a clinically relevant lower risk of recurrent VT. These findings suggest a potential secondary benefit of statins among patients who have experienced an incident VT. © 2016 International Society on Thrombosis and Haemostasis.

  5. Diagnosis and ablation of multiform fascicular tachycardia.

    PubMed

    Sung, Raphael K; Kim, Albert M; Tseng, Zian H; Han, Frederick; Inada, Keiichi; Tedrow, Usha B; Viswanathan, Mohan N; Badhwar, Nitish; Varosy, Paul D; Tanel, Ronn; Olgin, Jeffrey E; Stephenson, William G; Scheinman, Melvin

    2013-03-01

    Fascicular tachycardia (FT) is an uncommon cause of monomorphic sustained ventricular tachycardia (VT). We describe 6 cases of FT with multiform QRS morphologies. Six of 823 consecutive VT cases were retrospectively analyzed and found attributable to FT with multiform QRS patterns, with 3 cases exhibiting narrow QRS VT as well. All underwent electrophysiology study including fascicular potential mapping, entrainment pacing, and electroanatomic mapping. The first 3 cases describe similar multiform VT patterns with successful ablation in the upper mid septum. Initially, a right bundle branch block (RBBB) VT with superior axis was induced. Radiofrequency catheter ablation (RFCA) targeting the left posterior fascicle (LPF) resulted in a second VT with RBBB inferior axis. RFCA in the upper septum just apical to the LBB potential abolished VT in all cases. Cases 4 and 5 showed RBBB VT with alternating fascicular block compatible with upper septal dependent VT, resulting in bundle branch reentrant VT (BBRT) after ablation of LPF and left anterior fascicle (LAF). Finally, Cases 5 and 6 demonstrated spontaneous shift in QRS morphology during VT, implicating participation of a third fascicle. In Case 6, successful ablation was achieved over the proximal LAF, likely representing insertion of the auxiliary fascicle near the proximal LAF. Multiform FTs show a reentrant mechanism using multiple fascicular branches. We hypothesize that retrograde conduction over the septal fascicle produces alternate fascicular patterns as well as narrow VT forms. Ablation of the respective fascicle was successful in abolishing FT but does not preclude development of BBRT unless septal fascicle is targeted and ablated. © 2012 Wiley Periodicals, Inc.

  6. Thoracic Epidural Anesthesia Can Be Effective for the Short-Term Management of Ventricular Tachycardia Storm.

    PubMed

    Do, Duc H; Bradfield, Jason; Ajijola, Olujimi A; Vaseghi, Marmar; Le, John; Rahman, Siamak; Mahajan, Aman; Nogami, Akihiko; Boyle, Noel G; Shivkumar, Kalyanam

    2017-10-27

    Novel therapies aimed at modulating the autonomic nervous system, including thoracic epidural anesthesia (TEA), have been shown in small case series to be beneficial in treating medically refractory ventricular tachycardia (VT) storm. However, it is not clear when these options should be considered. We reviewed a multicenter experience with TEA in the management of VT storm to determine its optimal therapeutic use. Data for 11 patients in whom TEA was instituted for VT storm between July 2005 and March 2016 were reviewed to determine the clinical characteristics, outcomes, and role in management. The clinical presentation was incessant VT in 7 (64%), with polymorphic VT in 3 (27%) and monomorphic VT in 8 (73%). The underlying conditions were nonischemic cardiomyopathy in 5 (45%), ischemic cardiomyopathy in 3 (27%), and hypertrophic cardiomyopathy, Brugada syndrome, and cardiac lipoma in 1 (9%) each. Five (45%) had a complete and 1 (9%) had a partial response to TEA; 4 of the complete responders had incessant VT. All 4 patients with a documented response to deep sedation demonstrated a complete response to TEA. More than half of the patients with VT storm in our series responded to TEA. TEA may be effective and should be considered as a therapeutic option in patients with VT storm, especially incessant VT, who are refractory to initial management. Improvement in VT burden with deep sedation may suggest that sympathoexcitation plays a key role in perpetuating VT and predict a positive response to TEA. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  7. Angiotensin II effects on ischemic focal ventricular tachycardia are predominantly mediated through myocardial AT(2) receptor.

    PubMed

    Gopinathannair, Rakesh; Chaudhary, Ashok K; Xing, Dezhi; Ely, Debra; Zheng, Wei; Martins, James B

    2009-11-01

    Ischemic focal ventricular tachycardia (VT) occurs in animals and humans. Angiotensin-converting enzyme inhibitors and receptor blockers reduce sudden death in patients with ischemic heart disease. In our dog model of coronary artery occlusion (CAO), we tested the hypothesis that angiotensin II (AGII) will selectively promote focal VT and that the specific AT(2) blocker PD-123319 (PD), or AT(1) blocker losartan, will affect this VT. Anesthetized dogs (n = 90) underwent CAO, followed by three-dimensional activation mapping of inducible VT. Dogs without VT in 1-3 h after CAO received AGII, and those with VT received either PD or losartan. Focal endocardium excised from ischemic sites was studied in vitro with standard microelectrode. Of 33 dogs with no inducible VT, AGII infusion resulted in sustained VT of only focal Purkinje origin in 13 (39%) compared with 0 of 20 dogs with saline. Of 26 dogs with inducible VT at baseline, given PD, reinduction was blocked in 8 of 10 (P < 0.05) focal VT, but only 1 of 15 with reentry. In contrast, of 11 dogs given losartan, reinduction of either mechanism was not blocked. In vitro triggered activity in Purkinje was blocked by PD in 13 of 19 (P < 0.05), but not by losartan in 8. Also, triggered activity was promoted by AGII, losartan, or the combination in 9 of 12 tissues. AGII promotes only focal, mainly Purkinje ischemic VT. PD, but not losartan, preferentially blocked focal VT, which is likely due to triggered activity due to delayed afterdepolarizations in Purkinje.

  8. Improving ovarian tissue cryopreservation for oncologic patients: slow freezing versus vitrification, effect of different procedures and devices.

    PubMed

    Herraiz, Sonia; Novella-Maestre, Edurne; Rodríguez, Beatriz; Díaz, César; Sánchez-Serrano, María; Mirabet, Vicente; Pellicer, Antonio

    2014-03-01

    To compare slow freezing (SF) with four vitrification techniques (VT) for cryopreservation of ovarian tissue (OT) and to evaluate the best protocol for human OT in a xenograft model. Experimental study. University hospital. Patients undergoing fertility preservation. Ovariectomized nude mice. Cryopreservation of bovine OT after SF and four VTs (VT1, VT2, VT3, and VT4) by combining two cryoprotectant vitrification solutions (VS1 and VS2) and two devices (metallic grid and ethyl vinyl acetate bag), after which the cryopreservation of human OT by SF and VT1 and xenograft into nude mice. Follicular densities, proliferation, vascularization, fibrosis, apoptosis, tissue viability. The in vitro study in bovine OT showed a lower percentage of quiescent follicles in the SF group but not in the vitrification groups (VT1-VT4). Apoptosis increased and cell proliferation decreased in all the experimental groups except VT1 (20% ethylene glycol, 20% dimethyl sulfoxide, 0.5 M sucrose, and 20% synthetic serum substitute in HEPES-buffered M199 culture media with Cryotissue metallic grids). Tissue viability was diminished in VT3, and the SF-xenografted human samples showed reduced primordial and secondary densities and unbalanced follicular populations when compared with fresh and VT1 tissue. VT1 offers similar conditions to fresh tissue for follicular density, proliferation, viability, and cell death and preserves a larger population of quiescent follicles than SF after transplantation, thus ensuring the maintenance of graft potential fertility. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  9. KA-111, Phase C, M-1 Propellant Tests: Deflagration in Partial Confinement.

    DTIC Science & Technology

    1991-07-01

    DNA Test Director and Mr. R. !. Flory, Washington Research Center, was Program Coordinator. The DDESB, NDCS , and SSO Technical Monitors for Phase C...to simulate the chamber and access tunnel proportions of the Shallow Underground Tunnel /Chamber Explosion Test conducted at China Lake, CA, in 1988...The chamber and access tunnel at China Lake had the following dimensions (volume, cross-sectional area and length): Chamber: V. - 331.2 m 3 Tunnel : Vt

  10. Distribution of the Vasotocin Subtype Four Receptor (VT4R) in the Anterior Pituitary Gland of the Chicken, Gallus gallus, and its Possible Role in the Avian Stress Response.

    PubMed

    Selvam, R; Jurkevich, A; Kang, S W; Mikhailova, M V; Cornett, L E; Kuenzel, W J

    2013-01-01

    The neurohormone arginine vasotocin (AVT) in non mammalian vertebrates is homologous to arginine vasopressin (AVP) in mammals. Its actions are mediated via G protein-coupled receptors that belong to the vasotocin/mesotocin family. Because of the known regulatory effects of nonapeptide hormones on anterior pituitary functions, receptor subtypes in that family have been proposed to be located in anterior pituitary cells. Recently, an avian vasotocin receptor subtype designated VT4R has been cloned, which shares 69% sequence homology with a human vasopressin receptor, the V1aR. In the present study, a polyclonal antibody to the VT4R was developed and validated to confirm its specificity to the VT4R. The antibody was used to test the hypothesis that the VT4R is present in the avian anterior pituitary and is specifically associated with certain cell types, where its expression is modulated by acute stress. Western blotting of membrane protein extracts from pituitary tissue, the use of HeLa cells transfected with the VT4R and peptide competition assays all confirmed the specificity of the antibody to the VT4R. Dual-labelling immunofluorescence microscopy was utilised to identify pituitary cell types that contained immunoreactive VT4R. The receptor was found to be widely distributed throughout the cephalic lobe but not in the caudal lobe of the anterior pituitary. Immunoreactive VT4R was associated with corticotrophs. Approximately 89% of immunolabelled corticotrophs were shown to contain the VT4R. The immunoreactive VT4R was not found in gonadotrophs, somatotrophs or lactotrophs. To determine a possible functional role of the VT4R and previously characterised VT2R, gene expression levels in the anterior pituitary were determined after acute immobilisation stress by quantitative reverse transcriptase-polymerase chain reaction. The results showed a significant increase in plasma corticosterone levels (three- to four-fold), a significant reduction of VT4R mRNA and an increase of VT2R mRNA (P < 0.05) in acutely immobilised chicks compared to controls. The data suggest a role of the VT4R in the avian stress response. © 2012 British Society for Neuroendocrinology.

  11. Usefulness of a mobile phone with video telephony in identifying the correct landmark for performing needle thoracocentesis.

    PubMed

    You, J S; Park, S; Chung, S P; Park, J W

    2009-03-01

    A needle thoracocentesis should be performed with maximal safety and optimal efficacy in mind. Mobile video telephony (VT) could be used to facilitate instructions for the accurate performance of needle thoracocentesis in an emergency setting. This new communication method will increase the accuracy of identifying the relevant anatomical site during the decompression technique. A prospective randomised manikin study was performed to investigate the effectiveness of using VT as a method of instruction for the identification of anatomical landmarks during the performance of needle thoracocentesis. The overall success rate was significantly higher in the VT group which performed needle thoracocentesis under the guidance of VT than in the non-VT group who performed the procedure without VT-aided instruction. The instrument difficulty score and procedure satisfaction score were significantly lower in the VT group than in the non-VT group. Identification of the correct anatomical landmark for needle thoracocentesis can be performed with instructions provided via VT because a dispatcher can monitor every step and provide correct instructions. This new technology will improve critical care medicine.

  12. A Quantitative Comparison of the Behavior of Human Ventricular Cardiac Electrophysiology Models in Tissue

    PubMed Central

    Elshrif, Mohamed M.; Cherry, Elizabeth M.

    2014-01-01

    Numerical integration of mathematical models of heart cell electrophysiology provides an important computational tool for studying cardiac arrhythmias, but the abundance of available models complicates selecting an appropriate model. We study the behavior of two recently published models of human ventricular action potentials, the Grandi-Pasqualini-Bers (GPB) and the O'Hara-Virág-Varró-Rudy (OVVR) models, and compare the results with four previously published models and with available experimental and clinical data. We find the shapes and durations of action potentials and calcium transients differ between the GPB and OVVR models, as do the magnitudes and rate-dependent properties of transmembrane currents and the calcium transient. Differences also occur in the steady-state and S1–S2 action potential duration and conduction velocity restitution curves, including a maximum conduction velocity for the OVVR model roughly half that of the GPB model and well below clinical values. Between single cells and tissue, both models exhibit differences in properties, including maximum upstroke velocity, action potential amplitude, and minimum diastolic interval. Compared to experimental data, action potential durations for the GPB and OVVR models agree fairly well (although OVVR epicardial action potentials are shorter), but maximum slopes of steady-state restitution curves are smaller. Although studies show alternans in normal hearts, it occurs only in the OVVR model, and only for a narrow range of cycle lengths. We find initiated spiral waves do not progress to sustained breakup for either model. The dominant spiral wave period of the GPB model falls within clinically relevant values for ventricular tachycardia (VT), but for the OVVR model, the dominant period is longer than periods associated with VT. Our results should facilitate choosing a model to match properties of interest in human cardiac tissue and to replicate arrhythmia behavior more closely. Furthermore, by indicating areas where existing models disagree, our findings suggest avenues for further experimental work. PMID:24416228

  13. [Evolution of breathing pattern and ventilation at maximal exercise during growth. Definition of reference values].

    PubMed

    Prioux, J; Mercier, J; Ramonatxo, M; Granier, P; Mercier, B; Prefaut, C

    1995-01-01

    The aim of the study was to define the changes of parameters of breathing pattern and ventilation (VE) as a function of age during maximal exercise in children. A multi-longitudinal survey was conducted in forty four untrained schoolboys, divided in three groups with initial age of 11.2 years for group I, 12.9 years for group II, and 14.9 for group III. These children were subsequently followed three years ago at the same period. The range age was thus 11.2 to 16.9 years. This study showed that, during growth, ventilation (VE max), tidal volume (VT max) and mean inspiratory flow (VT/TI max) increased significantly with age, that inspiratory frequency (f max) decreased, that inspiratory, expiratory and total time of the respiratory cycle (TI max, TE max, TTOT max) increased slightly and that the inspiration fraction (TI/TTOT max) was identical at 11 and 17 years. Furthermore we observed that the peak height velocity and peak tidal volume velocity took place at the same age, i.e., 14 years and that those of weight and VT/TI at the same age of 15 years. In conclusion, this study allowed us to define reference values for breathing pattern at maximal exercise in sedentary boys and to specify the relation between growth and parameters of breathing pattern in these children.

  14. Ventilatory thresholds determined from HRV: comparison of 2 methods in obese adolescents.

    PubMed

    Quinart, S; Mourot, L; Nègre, V; Simon-Rigaud, M-L; Nicolet-Guénat, M; Bertrand, A-M; Meneveau, N; Mougin, F

    2014-03-01

    The development of personalised training programmes is crucial in the management of obesity. We evaluated the ability of 2 heart rate variability analyses to determine ventilatory thresholds (VT) in obese adolescents. 20 adolescents (mean age 14.3±1.6 years and body mass index z-score 4.2±0.1) performed an incremental test to exhaustion before and after a 9-month multidisciplinary management programme. The first (VT1) and second (VT2) ventilatory thresholds were identified by the reference method (gas exchanges). We recorded RR intervals to estimate VT1 and VT2 from heart rate variability using time-domain analysis and time-varying spectral-domain analysis. The coefficient correlations between thresholds were higher with spectral-domain analysis compared to time-domain analysis: Heart rate at VT1: r=0.91 vs. =0.66 and VT2: r=0.91 vs. =0.66; power at VT1: r=0.91 vs. =0.74 and VT2: r=0.93 vs. =0.78; spectral-domain vs. time-domain analysis respectively). No systematic bias in heart rate at VT1 and VT2 with standard deviations <6 bpm were found, confirming that spectral-domain analysis could replace the reference method for the detection of ventilatory thresholds. Furthermore, this technique is sensitive to rehabilitation and re-training, which underlines its utility in clinical practice. This inexpensive and non-invasive tool is promising for prescribing physical activity programs in obese adolescents. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Long-Term Outcome With Catheter Ablation of Ventricular Tachycardia in Patients With Arrhythmogenic Right Ventricular Cardiomyopathy.

    PubMed

    Santangeli, Pasquale; Zado, Erica S; Supple, Gregory E; Haqqani, Haris M; Garcia, Fermin C; Tschabrunn, Cory M; Callans, David J; Lin, David; Dixit, Sanjay; Hutchinson, Mathew D; Riley, Michael P; Marchlinski, Francis E

    2015-12-01

    Catheter ablation of ventricular tachycardia (VT) in arrhythmogenic right ventricular cardiomyopathy improves short-term VT-free survival. We sought to determine the long-term outcomes of VT control and need for antiarrhythmic drug therapy after endocardial (ENDO) and adjuvant epicardial (EPI) substrate modification in patients with arrhythmogenic right ventricular cardiomyopathy. We examined 62 consecutive patients with Task Force criteria for arrhythmogenic right ventricular cardiomyopathy referred for VT ablation with a minimum follow-up of 1 year. Catheter ablation was guided by activation/entrainment mapping for tolerated VT and pacemapping/targeting of abnormal substrate for unmappable VT. Adjuvant EPI ablation was performed when recurrent VT or persistent inducibility after ENDO-only ablation. Endocardial plus adjuvant EPI ablation was performed in 39 (63%) patients, including 13 who crossed over to ENDO-EPI after VT recurrence during follow-up, after ENDO-only ablation. Before ablation, 54 of 62 patients failed a mean of 2.4 antiarrhythmic drugs, including amiodarone in 29 (47%) patients. During follow-up of 56±44 months after the last ablation, VT-free survival was 71% with only a single VT episode in additional 9 patients (15%). At last follow-up, 39 (64%) patients were only on β-blockers or no treatment, 21 were on class 1 or 3 antiarrhythmic drugs (11 for atrial arrhythmias), and 2 were on amiodarone as a bridge to heart transplantation. The long-term outcome after ENDO and adjuvant EPI substrate ablation of VT in arrhythmogenic right ventricular cardiomyopathy is good. Most patients have complete VT control without amiodarone therapy and limited need for antiarrhythmic drugs. © 2015 American Heart Association, Inc.

  16. MAGNETIC VT study: a prospective, multicenter, post-market randomized controlled trial comparing VT ablation outcomes using remote magnetic navigation-guided substrate mapping and ablation versus manual approach in a low LVEF population.

    PubMed

    Di Biase, Luigi; Tung, Roderick; Szili-Torok, Tamás; Burkhardt, J David; Weiss, Peter; Tavernier, Rene; Berman, Adam E; Wissner, Erik; Spear, William; Chen, Xu; Neužil, Petr; Skoda, Jan; Lakkireddy, Dhanunjaya; Schwagten, Bruno; Lock, Ken; Natale, Andrea

    2017-04-01

    Patients with ischemic cardiomyopathy (ICM) are prone to scar-related ventricular tachycardia (VT). The success of VT ablation depends on accurate arrhythmogenic substrate localization, followed by optimal delivery of energy provided by constant electrode-tissue contact. Current manual and remote magnetic navigation (RMN)-guided ablation strategies aim to identify a reentry circuit and to target a critical isthmus through activation and entrainment mapping during ongoing tachycardia. The MAGNETIC VT trial will assess if VT ablation using the Niobe™ ES magnetic navigation system results in superior outcomes compared to a manual approach in subjects with ischemic scar VT and low ejection fraction. This is a randomized, single-blind, prospective, multicenter post-market study. A total of 386 subjects (193 per group) will be enrolled and randomized 1:1 between treatment with the Niobe ES system and treatment via a manual procedure at up to 20 sites. The study population will consist of patients with ischemic cardiomyopathy with left ventricular ejection fraction (LVEF) of ≤35% and implantable cardioverter defibrillator (ICD) who have sustained monomorphic VT. The primary study endpoint is freedom from any recurrence of VT through 12 months. The secondary endpoints are acute success; freedom from any VT at 1 year in a large-scar subpopulation; procedure-related major adverse events; and mortality rate through 12-month follow-up. Follow-up will consist of visits at 3, 6, 9, and 12 months, all of which will include ICD interrogation. The MAGNETIC VT trial will help determine whether substrate-based ablation of VT with RMN has clinical advantages over manual catheter manipulation. Clinicaltrials.gov identifier: NCT02637947.

  17. Long-Term Outcomes of Catheter Ablation of Ventricular Tachycardia in Patients With Cardiac Sarcoidosis.

    PubMed

    Muser, Daniele; Santangeli, Pasquale; Pathak, Rajeev K; Castro, Simon A; Liang, Jackson J; Magnani, Silvia; Hayashi, Tatsuya; Garcia, Fermin C; Hutchinson, Mathew D; Supple, Gregory E; Frankel, David S; Riley, Michael P; Lin, David; Schaller, Robert D; Desjardins, Benoit; Dixit, Sanjay; Callans, David J; Zado, Erica S; Marchlinski, Francis E

    2016-08-01

    Catheter ablation (CA) of ventricular tachycardia (VT) in patients with cardiac sarcoidosis can be challenging because of the complex underlying substrate. We sought to determine the long-term outcome of CA of VT in patients with cardiac sarcoidosis. We enrolled 31 patients (age, 55±10 years) with diagnosis of cardiac sarcoidosis based on Heart Rhythm Society criteria and VT who underwent CA. In 23 (74%) patients, preprocedure cardiac magnetic resonance imaging and positron emission tomographic (PET) evaluation were performed. Preprocedure magnetic resonance imaging was positive for late gadolinium enhancement in 21 of 23 (91%) patients, whereas abnormal 18-fluorodeoxyglucose uptake was found in 15 of 23 (65%) cases. In 14 of 15 patients with positive PET at baseline, PET was repeated after 6.1±3.7-month follow-up. After a median follow-up of 2.5 (range, 0-10.5) years, 1 (3%) patient died and 4 (13%) underwent heart transplant. Overall VT-free survival was 55% at 2-year follow-up. Among the 16 (52%) patients with VT recurrences, CA resulted in a significant reduction of VT burden, with 8 (50%) having only isolated (1-3) VT episodes and only 1 patient with recurrent VT storm. The presence of late gadolinium enhancement at magnetic resonance imaging, a positive PET at baseline, and lack of PET improvement over follow-up were associated with increased risk of recurrent VT. In patients with cardiac sarcoidosis and VT, CA is effective in achieving long-term freedom from VT or improvement in VT burden in the majority of patients. The presence of late gadolinium enhancement at magnetic resonance imaging, a positive PET scan at baseline, or lack of improvement at repeat PET over follow-up predict worse arrhythmia-free survival. © 2016 American Heart Association, Inc.

  18. Pre-Clinical Model to Study Recurrent Venous Thrombosis in the Inferior Vena Cava.

    PubMed

    Andraska, Elizabeth A; Luke, Catherine E; Elfline, Megan A; Henke, Samuel P; Madapoosi, Siddharth S; Metz, Allan K; Hoinville, Megan E; Wakefield, Thomas W; Henke, Peter K; Diaz, Jose A

    2018-06-01

     Patients undergoing deep vein thrombosis (VT) have over 30% recurrence, directly increasing their risk of post-thrombotic syndrome. Current murine models of inferior vena cava (IVC) VT model host one thrombosis event.  We aimed to develop a murine model to study IVC recurrent VT in mice.  An initial VT was induced using the electrolytic IVC model (EIM) with constant blood flow. This approach takes advantage of the restored vein lumen 21 days after a single VT event in the EIM demonstrated by ultrasound. We then induced a second VT 21 days later, using either EIM or an IVC ligation model for comparison. The control groups were a sham surgery and, 21 days later, either EIM or IVC ligation. IVC wall and thrombus were harvested 2 days after the second insult and analysed for IVC and thrombus size, gene expression of fibrotic markers, histology for collagen and Western blot for citrullinated histone 3 (Cit-H3) and fibrin.  Ultrasound confirmed the first VT and its progressive resolution with an anatomical channel allowing room for the second thrombus by day 21. As compared with a primary VT, recurrent VT has heavier walls with significant up-regulation of transforming growth factor-β (TGF-β), elastin, interleukin (IL)-6, matrix metallopeptidase 9 (MMP9), MMP2 and a thrombus with high citrullinated histone-3 and fibrin content.  Experimental recurrent thrombi are structurally and compositionally different from the primary VT, with a greater pro-fibrotic remodelling vein wall profile. This work provides a VT recurrence IVC model that will help to improve the current understanding of the biological mechanisms and directed treatment of recurrent VT. Schattauer GmbH Stuttgart.

  19. Comparison of affective responses during and after low volume high-intensity interval exercise, continuous moderate- and continuous high-intensity exercise in active, untrained, healthy males.

    PubMed

    Niven, Ailsa; Thow, Jacqueline; Holroyd, Jack; Turner, Anthony P; Phillips, Shaun M

    2018-09-01

    This study compared affective responses to low volume high-intensity interval exercise (HIIE), moderate-intensity continuous exercise (MICE) and high-intensity continuous exercise (HICE). Twelve untrained males ([Formula: see text] 48.2 ± 6.7 ml·kg -1 ·min -1 ) completed MICE (30 min cycle at 85% of ventilatory threshold (VT)), HICE (cycle at 105% of VT matched with MICE for total work), and HIIE (10 x 6 s cycle sprints with 60 s recovery). Affective valence and perceived activation were measured before exercise, post warm-up, every 20% of exercise time, and 1, 5, 10, and 15 min post-exercise. Affective valence during exercise declined by 1.75 ± 2.42, 1.17 ± 1.99, and 0.42 ± 1.38 units in HICE, HIIE, and MICE, respectively, but was not statistically influenced by trial (P = 0.35), time (P = 0.06), or interaction effect (P = 0.08). Affective valence during HICE and HIIE was consistently less positive than MICE. Affective valence post-exercise was not statistically influenced by trial (P = 0.10) and at 5 min post-exercise exceeded end-exercise values (P = 0.048). Circumplex profiles showed no negative affect in any trial. Affective responses to low volume HIIE are similar to HICE but remain positive and rebound rapidly, suggesting it may be a potential alternative exercise prescription.

  20. Training Prescription Guided by Heart Rate Variability in Cycling.

    PubMed

    Javaloyes, Alejandro; Sarabia, Jose Manuel; Lamberts, Robert Patrick; Moya-Ramon, Manuel

    2018-05-29

    Road cycling is a sport with extreme physiological demands. Therefore, there is a need to find new strategies to improve performance. Heart rate variability (HRV) has been suggested as an effective alternative for prescribing training load against predefined training programs. The purpose of this study is to examine the effect of training prescription based on HRV in road cycling performance. Seventeen well-trained cyclists participated in this study. After an initial evaluation week (EW), cyclists performed 4 baseline weeks (BW) of standardized training to establish their resting HRV. Then, cyclists were divided into two groups, a HRV-guided group (HRV-G) and a traditional periodization group (TRAD) and they carried out 8 training weeks (TW). Cyclists performed two EW, after and before TW. During the EW, cyclists performed: (1) a graded exercise test to assess VO2max, peak power output (PPO) and ventilatory thresholds with their corresponding power output (VT1, VT2, WVT1, and WVT2, respectively) and (2) a 40-min simulated time-trial. HRV-G improved PPO (5.1 ± 4.5 %; p = 0.024), WVT2 (13.9 ± 8.8 %; p = 0.004) and 40TT (7.3 ± 4.5 %; p = 0.005). VO2max and WVT1 remained similar. TRAD did not improve significantly after TW. There were no differences between groups. However, magnitude-based inference analysis showed likely beneficial and possibly beneficial effects for HRV-G instead of TRAD in 40TT and PPO, respectively. Daily training prescription based on HRV could result in a better performance enhancement than a traditional periodization in well-trained cyclists.

  1. VTGRAPH - GRAPHIC SOFTWARE TOOL FOR VT TERMINALS

    NASA Technical Reports Server (NTRS)

    Wang, C.

    1994-01-01

    VTGRAPH is a graphics software tool for DEC/VT or VT compatible terminals which are widely used by government and industry. It is a FORTRAN or C-language callable library designed to allow the user to deal with many computer environments which use VT terminals for window management and graphic systems. It also provides a PLOT10-like package plus color or shade capability for VT240, VT241, and VT300 terminals. The program is transportable to many different computers which use VT terminals. With this graphics package, the user can easily design more friendly user interface programs and design PLOT10 programs on VT terminals with different computer systems. VTGRAPH was developed using the ReGis Graphics set which provides a full range of graphics capabilities. The basic VTGRAPH capabilities are as follows: window management, PLOT10 compatible drawing, generic program routines for two and three dimensional plotting, and color graphics or shaded graphics capability. The program was developed in VAX FORTRAN in 1988. VTGRAPH requires a ReGis graphics set terminal and a FORTRAN compiler. The program has been run on a DEC MicroVAX 3600 series computer operating under VMS 5.0, and has a virtual memory requirement of 5KB.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dale, R.; Sáez, D., E-mail: rdale@umh.es, E-mail: diego.saez@uv.es

    The vector-tensor (VT) theory of gravitation revisited in this article was studied in previous papers, where it was proved that VT works and deserves attention. New observational data and numerical codes have motivated further development which is presented here. New research has been planed with the essential aim of proving that current cosmological observations, including Planck data, baryon acoustic oscillations (BAO), and so on, may be explained with VT, a theory which accounts for a kind of dark energy which has the same equation of state as vacuum. New versions of the codes CAMB and COSMOMC have been designed formore » applications to VT, and the resulting versions have been used to get the cosmological parameters of the VT model at suitable confidence levels. The parameters to be estimated are the same as in general relativity (GR), plus a new parameter D . For D = 0, VT linear cosmological perturbations reduces to those of GR, but the VT background may explain dark energy. The fits between observations and VT predictions lead to non vanishing | D | upper limits at the 1σ confidence level. The value D = 0 is admissible at this level, but this value is not that of the best fit in any case. Results strongly suggest that VT may explain current observations, at least, as well as GR; with the advantage that, as it is proved in this paper, VT has an additional parameter which facilitates adjustments to current observational data.« less

  3. Acute severe asthma: performance of ventilator at simulated altitude.

    PubMed

    Tourtier, Jean-Pierre; Forsans, Emma; Leclerc, Thomas; Libert, Nicolas; Ramsang, Solange; Tazarourte, Karim; Man, Michel; Borne, Marc

    2011-04-01

    Exacerbation of asthma can be seen during air transport. Severe patients, not responding to conventional therapy, require ventilator support. We evaluated the performance of two transport ventilators, built with turbine technology, the T-birdVSO2 and the LTV-1000, for use during aeromedical evacuation of acute severe asthma. We have assessed the ability of both the ventilators to deliver to an acute severe asthma model a tidal volume (Vt) set at different simulated altitudes, by changing the ambient air pressure. The simulated cabin altitudes were 1500, 2500, and 3000 m (decompression chamber). Vt was set at 700 and 400 ml in an acute severe asthma lung model. Comparisons of the preset with the actual measured values were accomplished using a t-test. Comparisons between the actual delivered Vt and set Vt showed a significant difference starting at 1500 m for both the ventilators. The T-birdVSO2 showed a decrease in the volume delivered, with a negative variation of more than 10% compared with the Vt set. The LTV-1000 showed mostly an increase in the volume delivered. The delivered Vt remained within 10% of the set Vt. The accuracy of Vt delivery was superior with the LTV-1000 than with the T-birdVSO2, but the higher delivered Vt of the LTV-1000 are likely to be more harmful than lower delivered Vt of the T-birdVSO2.

  4. Outcome of Radiofrequency Catheter Ablation as a non-pharmacological therapy for idiopathic Ventricular Tachycardia.

    PubMed

    Samore, Naseer Ahmed; Imran Majeed, Syed Muhammad; Kayani, Azhar Mahmud; Bhalli, Muhammad Asif; Shabbir, Muhammad

    2009-09-01

    To determine the outcome of Radiofrequency Catheter Ablation (RFCA) as a non-pharmacological curative therapy for idiopathic Ventricular Tachycardia (VT) and to identify procedure-related complications. Descriptive study. The Armed Forces Institute of Cardiology and National Institute of Heart Diseases, Rawalpindi, from February 2001 to October 2008. Ninety eight consecutive patients with idiopathic VT, resistant to drug therapy, who underwent Electrophysiology Studies (EPS) radiofrequency catheter ablation were enrolled. Clinical and electrophysiological variables were recorded and a descriptive analysis was done. Out of the 98 patients, 79 were males (80.6%). The mean age was 33.29+11.93 years. Modes of presentation were sustained VT, Repetitive Monomorphic VT (RMVT), Non-sustained VT (NSVT) and Ventricular Premature Beats (VPBs). Right Ventricular Outflow Tract (RVOT) VT was found in 37 patients, 37 had Idiopathic Left Ventricular Tachycardia (ILVT), 20 had Left Ventricular Outflow Tract (LVOT) VT, and Inflow Right Ventricular Tachycardia (IRVT) was found in 7 patients. Other sites of origin of VT were infrequent. Eight patients had dual morphologies of VT. Atrioventricular Nodal Re-entry Tachycardia (AVNRT) was found in 8 patients. RFCA was successful in abolishing inducible VT in 88 patients. One patient developed complete AV block requiring a permanent pacemaker. Results of this study confirm a high degree of success and safety of radiofrequency catheter ablation as curative therapy for idiopathic ventricular tachycardia.

  5. Impact of Different Ventilation Strategies on Driving Pressure, Mechanical Power, and Biological Markers During Open Abdominal Surgery in Rats.

    PubMed

    Maia, Lígia de A; Samary, Cynthia S; Oliveira, Milena V; Santos, Cintia L; Huhle, Robert; Capelozzi, Vera L; Morales, Marcelo M; Schultz, Marcus J; Abreu, Marcelo G; Pelosi, Paolo; Silva, Pedro L; Rocco, Patricia Rieken Macedo

    2017-10-01

    Intraoperative mechanical ventilation may yield lung injury. To date, there is no consensus regarding the best ventilator strategy for abdominal surgery. We aimed to investigate the impact of the mechanical ventilation strategies used in 2 recent trials (Intraoperative Protective Ventilation [IMPROVE] trial and Protective Ventilation using High versus Low PEEP [PROVHILO] trial) on driving pressure (ΔPRS), mechanical power, and lung damage in a model of open abdominal surgery. Thirty-five Wistar rats were used, of which 28 were anesthetized, and a laparotomy was performed with standardized bowel manipulation. Postoperatively, animals (n = 7/group) were randomly assigned to 4 hours of ventilation with: (1) tidal volume (VT) = 7 mL/kg and positive end-expiratory pressure (PEEP) = 1 cm H2O without recruitment maneuvers (RMs) (low VT/low PEEP/RM-), mimicking the low-VT/low-PEEP strategy of PROVHILO; (2) VT = 7 mL/kg and PEEP = 3 cm H2O with RMs before laparotomy and hourly thereafter (low VT/moderate PEEP/4 RM+), mimicking the protective ventilation strategy of IMPROVE; (3) VT = 7 mL/kg and PEEP = 6 cm H2O with RMs only before laparotomy (low VT/high PEEP/1 RM+), mimicking the strategy used after intubation and before extubation in PROVHILO; or (4) VT = 14 mL/kg and PEEP = 1 cm H2O without RMs (high VT/low PEEP/RM-), mimicking conventional ventilation used in IMPROVE. Seven rats were not tracheotomized, operated, or mechanically ventilated, and constituted the healthy nonoperated and nonventilated controls. Low VT/moderate PEEP/4 RM+ and low VT/high PEEP/1 RM+, compared to low VT/low PEEP/RM- and high VT/low PEEP/RM-, resulted in lower ΔPRS (7.1 ± 0.8 and 10.2 ± 2.1 cm H2O vs 13.9 ± 0.9 and 16.9 ± 0.8 cm H2O, respectively; P< .001) and less mechanical power (63 ± 7 and 79 ± 20 J/min vs 110 ± 10 and 120 ± 20 J/min, respectively; P = .007). Low VT/high PEEP/1 RM+ was associated with less alveolar collapse than low VT/low PEEP/RM- (P = .03). E-cadherin expression was higher in low VT/moderate PEEP/4 RM+ than in low VT/low PEEP/RM- (P = .013) or high VT/low PEEP/RM- (P = .014). The extent of alveolar collapse, E-cadherin expression, and tumor necrosis factor-alpha correlated with ΔPRS (r = 0.54 [P = .02], r = -0.48 [P = .05], and r = 0.59 [P = .09], respectively) and mechanical power (r = 0.57 [P = .02], r = -0.54 [P = .02], and r = 0.48 [P = .04], respectively). In this model of open abdominal surgery based on the mechanical ventilation strategies used in IMPROVE and PROVHILO trials, lower mechanical power and its surrogate ΔPRS were associated with reduced lung damage.

  6. Sudden cardiac arrest in people with epilepsy in the community

    PubMed Central

    Lamberts, Robert J.; Blom, Marieke T.; Wassenaar, Merel; Bardai, Abdennasser; Leijten, Frans S.; de Haan, Gerrit-Jan; Sander, Josemir W.; Thijs, Roland D.

    2015-01-01

    Objective: To ascertain whether characteristics of ventricular tachycardia/fibrillation (VT/VF) differed between people with epilepsy and those without and which individuals with epilepsy were at highest risk. Methods: We ascertained 18 people with active epilepsy identified in a community-based registry of sudden cardiac arrest (SCA) with ECG-confirmed VT/VF (cases). We compared them with 470 individuals with VT/VF without epilepsy (VT/VF controls) and 54 individuals with epilepsy without VT/VF (epilepsy controls). Data on comorbidity, epilepsy severity, and medication use were collected and entered into (conditional) logistic regression models to identify determinants of VT/VF in epilepsy. Results: In most cases, there was an obvious (10/18) or presumed cardiovascular cause (5/18) in view of preexisting heart disease. In 2 of the 3 remaining events, near–sudden unexpected death in epilepsy (SUDEP) was established after successful resuscitation. Cases had a higher prevalence of congenital/inherited heart disease (17% vs 1%, p = 0.002), and experienced VT/VF at younger age (57 vs 64 years, p = 0.023) than VT/VF controls. VT/VF in cases occurred more frequently at/near home (89% vs 58%, p = 0.009), and was less frequently witnessed (72% vs 89%, p = 0.048) than in VT/VF controls. Cases more frequently had clinically relevant heart disease (50% vs 15%, p = 0.005) and intellectual disability (28% vs 1%, p < 0.001) than epilepsy controls. Conclusion: Cardiovascular disease rather than epilepsy characteristics is the main determinant of VT/VF in people with epilepsy in the community. SCA and SUDEP are partially overlapping disease entities. PMID:26092917

  7. Temporal and spectral characteristics of seismicity observed at Popocatepetl volcano, central Mexico

    USGS Publications Warehouse

    Arciniega-Ceballos, A.; Valdes-Gonzalez, C.; Dawson, P.

    2000-01-01

    Popocatepetl volcano entered an eruptive phase from December 21, 1994 to March 30, 1995, which was characterized by ash and fumarolic emissions. During this eruptive episode, the observed seismicity consisted of volcano-tectonic (VT) events, long-period (LP) events and sustained tremor. Before the initial eruption on December 21, VT seismicity exhibited no increase in number until a swarm of VT earthquakes was observed at 01:31 hours local time. Visual observations of the eruption occurred at dawn the next morning. LP activity increased from an average of 7 events a day in October 1994 to 22 events per day in December 1994. At the onset of the eruption, LP activity peaked at 49 events per day. LP activity declined until mid-January 1995 when no events were observed. Tremor was first observed about one day after the initial eruption and averaged 10 h per episode. By late February 1995, tremor episodes became more intermittent, lasting less than 5 min, and the number of LP events returned to pre-eruption levels (7 events per day). Using a spectral ratio technique, low-frequency oceanic microseismic noise with a predominant peak around 7 s was removed from the broadband seismic signal of tremor and LP events. Stacks of corrected tremor episodes and LP events show that both tremor and LP events contain similar frequency features with major peaks around 1.4 Hz. Frequency analyses of LP events and tremor suggest a shallow extended source with similar radiation pattern characteristics. The distribution of VT events (between 2.5 and 10 km) also points to a shallow source of the tremor and LP events located in the first 2500 m beneath the crater. Under the assumption that the frequency characteristics of the signals are representative of an oscillator we used a fluid-filled-crack model to infer the length of the resonator.

  8. Verocytotoxin-induced apoptosis of human microvascular endothelial cells.

    PubMed

    Pijpers, A H; van Setten, P A; van den Heuvel, L P; Assmann, K J; Dijkman, H B; Pennings, A H; Monnens, L A; van Hinsbergh, V W

    2001-04-01

    The pathogenesis of the epidemic form of hemolytic uremic syndrome is characterized by endothelial cell damage. In this study, the role of apoptosis in verocytotoxin (VT)-mediated endothelial cell death in human glomerular microvascular endothelial cells (GMVEC), human umbilical vein endothelial cells, and foreskin microvascular endothelial cells (FMVEC) was investigated. VT induced apoptosis in GMVEC and human umbilical vein endothelial cells when the cells were prestimulated with the inflammatory mediator tumor necrosis factor-alpha (TNF-alpha). FMVEC displayed strong binding of VT and high susceptibility to VT under basal conditions, which made them suitable for the study of VT-induced apoptosis without TNF-alpha interference. On the basis of functional (flow cytometry and immunofluorescence microscopy using FITC-conjugated annexin V and propidium iodide), morphologic (transmission electron microscopy), and molecular (agarose gel electrophoresis of cellular DNA fragments) criteria, it was documented that VT induced programmed cell death in microvascular endothelial cells in a dose- and time-dependent manner. Furthermore, whereas partial inhibition of protein synthesis by VT was associated with a considerable number of apoptotic cells, comparable inhibition of protein synthesis by cycloheximide was not. This suggests that additional pathways, independent of protein synthesis inhibition, may be involved in VT-mediated apoptosis in microvascular endothelial cells. Specific inhibition of caspases by Ac-Asp-Glu-Val-Asp-CHO, but not by Ac-Tyr-Val-Ala-Asp-CHO, was accompanied by inhibition of VT-induced apoptosis in FMVEC and TNF-alpha-treated GMVEC. These data indicate that VT can induce apoptosis in human microvascular endothelial cells.

  9. Interaction of Viscotoxins A3 and B with Membrane Model Systems: Implications to Their Mechanism of Action

    PubMed Central

    Giudici, Marcela; Pascual, Roberto; de la Canal, Laura; Pfüller, Karola; Pfüller, Uwe; Villalaín, José

    2003-01-01

    Viscotoxins are small proteins that are thought to interact with biomembranes, displaying different toxic activities against a varied number of cell types, being viscotoxin A3 (VtA3) the most cytotoxic whereas viscotoxin B (VtB) is the less potent. By using infrared and fluorescence spectroscopies, we have studied the interaction of VtA3 and VtB, both wild and reduced ones, with model membranes containing negatively charged phospholipids. Both VtA3 and VtB present a high conformational stability, and a similar conformation both in solution and when bound to membranes. In solution, the infrared spectra of the reduced proteins show an increase in bandwidth compared to the nonreduced ones indicating a greater flexibility. VtA3 and VtB bind with high affinity to membranes containing negatively charged phospholipids and are motional restricted, their binding being dependent on phospholipid composition. Whereas nonreduced proteins maintain their structure when bound to membranes, reduced ones aggregate. Furthermore, leakage experiments show that wild proteins were capable of disrupting membranes whereas reduced proteins were not. The effect of VtA3 and VtB on membranes having different phospholipid composition is diverse, affecting the cooperativity and fluidity of the membranes. Viscotoxins interact with membranes in a complex way, most likely organizing themselves at the surface inducing the appearance of defects that lead to the destabilization and disruption of the membrane bilayer. PMID:12885644

  10. Long-term outcome of catheter ablation for left posterior fascicular ventricular tachycardia with the development of left posterior fascicular block and characteristics of repeat procedures.

    PubMed

    Luo, Bin; Zhou, Gongbu; Guo, Xiaogang; Liu, Xu; Yang, Jiandu; Sun, Qi; Ma, Jian; Zhang, Shu

    2017-06-01

    The present study aimed to retrospectively investigate long-term clinical outcomes of patients undergoing catheter ablation of left posterior fascicular ventricular tachycardia (LPF-VT) with the development of left posterior fascicular block (LPF block) and characteristics of repeat procedures. A total of 195 patients (mean age 29.76±1.03years, 16.4% females) who underwent catheter ablation for LPF-VT were consecutively enrolled. The earliest ventricular potential with a single fused Purkinje potential (PP) during VT and the PP located in the inferior-apical or mid-apical septum during SR were targeted for linear ablation. The endpoint of the procedure was noninducible VT and development of new-onset LPF block. Follow-up with clinic visits or telephonic interviews, electrocardiogram (ECG), or Holter monitoring was performed after the procedure. With a median follow-up of 85 (18,181) months, 20 patients were censored and 152 of 175 (86.86%) patients had long-term freedom from VT after a single procedure. No statistical difference in the outcome of catheter ablation of LPF-VT was found between inducible and non-inducible groups (P=0.89). Twenty-three patients exhibited recurrent LPF-VT. Seven of 23 patients developed new-onset left upper septal ventricular tachycardia that was successfully ablated. All the patients undergoing repeat procedures had freedom from VT. No procedural complications occurred. Ablation of LPF-VT using the development of LPF block as the endpoint is associated with a high procedural success rate. No difference in freedom from LPF-VT was found between inducible and non-inducible patients. New-onset LPF block recovery and non-early PP-QRS interval can be the predictors of LPF-VT repeat procedure. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Efficacy of the Clinical Agent VT-1161 against Fluconazole-Sensitive and -Resistant Candida albicans in a Murine Model of Vaginal Candidiasis

    PubMed Central

    Hoekstra, W. J.; Schotzinger, R. J.; Sobel, J. D.; Lilly, E. A.; Fidel, P. L.

    2015-01-01

    Vulvovaginal candidiasis (VVC) and recurrent VVC (RVVC) remain major health problems for women. VT-1161, a novel fungal CYP51 inhibitor which has potent antifungal activity against fluconazole-sensitive Candida albicans, retained its in vitro potency (MIC50 of ≤0.015 and MIC90 of 0.12 μg/ml) against 10 clinical isolates from VVC or RVVC patients resistant to fluconazole (MIC50 of 8 and MIC90 of 64 μg/ml). VT-1161 pharmacokinetics in mice displayed a high volume of distribution (1.4 liters/kg), high oral absorption (73%), and a long half-life (>48 h) and showed rapid penetration into vaginal tissue. In a murine model of vaginal candidiasis using fluconazole-sensitive yeast, oral doses as low as 4 mg/kg VT-1161 significantly reduced the fungal burden 1 and 4 days posttreatment (P < 0.0001). Similar VT-1161 efficacy was measured when an isolate highly resistant to fluconazole (MIC of 64 μg/ml) but fully sensitive in vitro to VT-1161 was used. When an isolate partially sensitive to VT-1161 (MIC of 0.12 μg/ml) and moderately resistant to fluconazole (MIC of 8 μg/ml) was used, VT-1161 remained efficacious, whereas fluconazole was efficacious on day 1 but did not sustain efficacy 4 days posttreatment. Both agents were inactive in treating an infection with an isolate that demonstrated weaker potency (MICs of 2 and 64 μg/ml for VT-1161 and fluconazole, respectively). Finally, the plasma concentrations of free VT-1161 were predictive of efficacy when in excess of the in vitro MIC values. These data support the clinical development of VT-1161 as a potentially more efficacious treatment for VVC and RVVC. PMID:26124165

  12. The association of ventricular tachycardia and endothelial dysfunction in the setting of acute myocardial infarction with ST elevation

    PubMed Central

    Škerk, Vedrana; Markotić, Alemka; Brkljačić, Diana Delić; Manola, Šime; Krčmar, Tomislav; Gabrić, Ivo Darko; Štajminger, Gordana; Pintarić, Hrvoje

    2013-01-01

    Background Ventricular tachycardia (VT) is frequently seen in ischemic settings like acute myocardial infarction with ST segment elevation (STEMI). Endothelial dysfunction (ED) represents inflammation and the loss of all protective features of the endothelium. We aimed to examine the association between VT and ED in patients with STEMI. Material/Methods The study included 90 subjects (30 with VT and acute STEMI, 30 with STEMI without VT, and 30 controls). Sera of all subjects were tested on ED markers by enzyme immunoassay: sICAM-1 (intracellular adhesive molecule-1), sVCAM-1 (vascular adhesive molecule-1), P- and E-selectins, and VEGF (vascular endothelial growth factor). In addition, CRP (C-reactive protein) was detected. Results Significantly increased values of low-density lipoprotein, triglycerides, leukocytes, creatinine, and the number of cigarettes smoked were observed among patients with VT+STEMI in comparison to controls. The levels of E-selectin were significantly lower in the VT+STEMI group than in the other groups, while the levels of VCAM-1 were significantly higher in the groups with STEMI and VT+STEMI compared to the controls. Lower levels of VEGF were recorded in STEMI and VT+STEMI groups compared to the control group. A significant correlation between CRP and VCAM-1 in patients with VT +STEMI was demonstrated. Conclusions We showed that ED may have a role in the immunopathogenesis of VT in patients with STEMI. The role of sE-selectin and correlation of sVCAM-1 with CRP as possible ED predictive markers in patients with VT+STEMI should be further investigated in a large cohort of patients. PMID:24253420

  13. The Association of Statin Therapy with the Risk of Recurrent Venous Thrombosis

    PubMed Central

    Smith, Nicholas L.; Harrington, Laura B.; Blondon, Marc; Wiggins, Kerri L.; Floyd, James S.; Sitlani, Colleen M.; McKnight, Barbara; Larson, Eric B.; Rosendaal, Frits R.; Heckbert, Susan R.; Psaty, Bruce M.

    2016-01-01

    Background Meta-analyses of randomized controlled trials suggest that treatment with HMG-CoA reductase inhibitors (statins) lowers the risk of incident venous thrombosis (VT), particularly among those without prevalent clinical cardiovascular disease (CVD). Whether this is true for the prevention of recurrent VT is debated. We used an observational inception cohort to estimate the association of current statin use with the risk of recurrent VT. Methods and Results The study setting was a large healthcare organization with detailed medical record and pharmacy information at cohort entry and throughout follow-up. We followed 2,798 subjects 18–89 years of age who experienced a validated incident VT between January 1, 2002 and December 31, 2010, for a first recurrent VT, validated by medical record review. During follow-up, 457 (16%) developed a first recurrent VT. In time-to-event models incorporating time-varying statin use and adjusting for potential confounders, current statin use was associated with a 26% lower risk of recurrent VT: HR=0.74; 95%CI: 0.59–0.94. Among cohort members free of CVD (n=2,134), current statin use was also associated with a lower risk (38%) of recurrent VT: HR=0.62; 95%CI: 0.45–0.85. We found similar results when restricting to new users of statins and in subgroups of different statin types and doses. Conclusions In a population-based cohort of subjects who had experienced an incident VT, statin use, compared with non-use, was associated with a clinically-relevant lower risk of recurrent VT. These findings suggest a potential secondary benefit of statins among patients who have experienced an incident VT. PMID:27061794

  14. Lung and chest wall impedances in the dog: effects of frequency and tidal volume.

    PubMed

    Barnas, G M; Stamenović, D; Lutchen, K R; Mackenzie, C F

    1992-01-01

    Dependences of the mechanical properties of the respiratory system on frequency (f) and tidal volume (VT) in the normal ranges of breathing are not clear. We measured, simultaneously and in vivo, resistance and elastance of the total respiratory system (Rrs and Ers), lungs (RL and EL), and chest wall (Rcw and Ecw) of five healthy anesthetized paralyzed dogs during sinusoidal volume oscillations at the trachea (50-300 ml, 0.2-2 Hz) delivered at a constant mean lung volume. Each dog showed the same f and VT dependences. The Ers and Ecw increased with increasing f to 1 Hz and decreased with increasing VT up to 200 ml. Although EL increased slightly with increasing f, it was independent of VT. The Rcw decreased from 0.2 to 2 Hz at all VT and decreased with increasing VT. Although the RL decreased from 0.2 to 0.6 Hz and was independent of VT, at higher f RL tended to increase with increasing f and VT (i.e., as peak flow increased). Finally, the f and VT dependences of Rrs were similar to those of Rcw below 0.6 Hz but mirrored RL at higher f. These data capture the competing influences of airflow nonlinearities vs. tissue nonlinearities on f and VT dependence of the lung, chest wall, and total respiratory system. More specifically, we conclude that 1) VT dependences in Ers and Rrs below 0.6 Hz are due to nonlinearities in chest wall properties, 2) above 0.6 Hz, the flow dependence of airways resistance dominates RL and Rrs, and 3) lung tissue behavior is linear in the normal range of breathing.

  15. Volume versus wiring transmission in the brain: a new theoretical frame for neuropsychopharmacology.

    PubMed

    Agnati, L F; Bjelke, B; Fuxe, K

    1995-01-01

    A volume transmission mode of communication in brain was implicit already in the early work of Golgi, who postulated the existence of electrical signals in the extracellular fluid (ECF) based on Volta's "wet conductor" made by solutions. The term volume transmission is taken from the term volume conduction describing the flow of ionic currents in the ECF as a basis for the electrocorticogram. The slow VT mode includes also chemical signals and is opposed to the fast synaptic (wiring) transmission. Every neuron may function in a dual mode, the synaptic and the volume transmission mode, when considering the autocrine and synaptic classes of communication. The paracrine- and neuroendocrine-like classes only involve the VT mode in the latter case including the CSF as a route. The chemical signals for VT are the neuropeptides, but also the classical transmitters, the monoamines, acetylcholine, GABA, and glutamate can participate, when they operate via slow, high affinity G protein coupled receptors. Ions such as K+, Ca++, and H+ also function as VT signals. The hypothesis is also introduced that CO2 can act as a multifacit long-distance VT and WT regulator besides being part of the CO2/HCO3 buffer. CO2 via regulating NMDA receptor sensitivity can also regulate NO formation, which represents a paracrine and fast VT signal. The therapy of CNS disorders is also discussed in the frame of the wiring and VT concept. Two therapeutical approaches can therefore be developed, one based on increasing WT and one based on increasing VT. In contrast to the WT therapy, which must preserve the electrotemporal code, the VT therapy can operate also with postsynaptic agonists. Therefore, a therapeutic effect with such a drug indicates that the deficiency in the communication process operates via VT. In view of the lack of very effective negative feedbacks in VT vs. WT, VT therapy may produce less tolerance and drug dependency.

  16. Predictors of new malignant ventricular arrhythmias after coronary surgery: a case-control study.

    PubMed

    Ascione, Raimondo; Reeves, Barnaby C; Santo, Kirkpatrick; Khan, Nouman; Angelini, Gianni D

    2004-05-05

    We sought to investigate the relationship between perioperative factors and the occurrence of ventricular tachycardia (VT) and ventricular fibrillation (VF), as well as the impact of VT/VF on early and late mortality. Both VT and VF are rare but serious complications after coronary artery bypass graft surgery (CABG), and their etiology and implications remain uncertain. Data on 4,411 consecutive patients undergoing CABG (1,154 [25.8%] had off-pump surgery) between April 1996 and September 2001 were extracted from a prospective database and analyzed. Odds ratios (ORs) describing associations between possible risk factors and VT/VF were estimated separately. Factors observed to be significantly associated with VT/VF were further investigated using multivariate logistic regression. Sixty-nine patients suffered VT/VF (1.6%). There were 61 (1.4%) in-hospital/30-day deaths, 15 among patients who had postoperative VT/VF (21.7%). Patient factors independently associated with an increase in the odds of VT/VF included age <65 years, female gender, body mass index <25 kg/m(2), unstable angina, moderate or poor ejection fraction, and the need for inotropes and an intra-aortic balloon pump (OR 1.72 to 4.47, p < 0.05). After adjustment, off-pump surgery was associated with a substantial but nonsignificant protective effect against VT/VF (OR 0.53, 95% confidence interval [CI] 0.25 to 1.13; p = 0.10). Actuarial survival at two years was 98.2% among patients who had VT/VF and who survived to discharge/30 days, compared with 97.0% for the control group (adjusted hazard ratio 0.96 (95% CI 0.40 to 2.31, p = 0.92). The incidence of VT/VF is low in patients undergoing coronary surgery but is associated with high in-hospital mortality. The late survival of the discharged VT/VF patients compares favorably with that of controls.

  17. Does core mobility of lumbar total disc arthroplasty influence sagittal and frontal intervertebral displacement? Radiologic comparison with fixed-core prosthesis

    PubMed Central

    Delécrin, Joël; Allain, Jérôme; Beaurain, Jacques; Steib, Jean-Paul; Chataigner, Hervé; Aubourg, Lucie; Huppert, Jean; Ameil, Marc; Nguyen, Jean-Michel

    2009-01-01

    Background An artificial disc prosthesis is thought to restore segmental motion in the lumbar spine. However, it is reported that disc prosthesis can increase the intervertebral translation (VT). The concept of the mobile-core prosthesis is to mimic the kinematic effects of the migration of the natural nucleus and therefore core mobility should minimize the VT. This study explored the hypothesis that core translation should influence VT and that a mobile core prosthesis may facilitate physiological motion. Methods Vertebral translation (measured with a new method presented here), core translation, range of motion (ROM), and distribution of flexion-extension were measured on flexion-extension, neutral standing, and lateral bending films in 89 patients (63 mobile-core [M]; 33 fixed-core [F]). Results At L4-5 levels the VT with M was lower than with F and similar to the VT of untreated levels. At L5-S1 levels the VT with M was lower than with F but was significantly different compared to untreated levels. At M levels a strong correlation was found between VT and core translation; the VT decreases as the core translation increases. At F levels the VT increases as the ROM increases. No significant difference was found between the ROM of untreated levels and levels implanted with either M or F. Regarding the mobility distribution with M and F we observed a deficit in extension at L5-S1 levels and a similar distribution at L4-5 levels compared to untreated levels. Conclusion The intervertebral mobility was different between M and F. The M at L4-5 levels succeeded to replicate mobility similar to L4-5 untreated levels. The M at L5-S1 succeeded in ROM, but failed regarding VT and mobility distribution. Nevertheless M minimized VT at L5-S1 levels. The F increased VT at both L4-5 and L5-S1. Clinical Relevance This study validates the concept that the core translation of an artificial lumbar disc prosthesis minimizes the VT. PMID:25802632

  18. Modulation of nitric oxide, hydrogen peroxide and cytokine production in a clonal macrophage model by the trichothecene vomitoxin (deoxynivalenol).

    PubMed

    Ji, G E; Park, S Y; Wong, S S; Pestka, J J

    1998-02-06

    Characterization of how vomitoxin (VT) and other trichothecenes affect macrophage regulatory and effector function may contribute to improved understanding of mechanisms by which these mycotoxins impact the immune system. The RAW 264.7 murine cell line was used as a macrophage model to assess effects of the VT on proliferation and the production of nitric oxide (NO), hydrogen peroxide (H2O2) and cytokines. Using the MTT cleavage assay, VT at concentrations of 50 ng/ml or higher was found to significantly decrease proliferation and viability of RAW 264.7 cells without stimulation or with stimulation by lipopolysaccharide (LPS) or interferon (IFN)-gamma. In the absence of an activation agent, VT (25-250 ng/ml) had negligible effects on the production of NO, H2O2, and cytokines. Upon activation with LPS at concentrations of 10 to 100 ng/ml, VT at 25-100 ng/ml markedly enhanced production of H2O2 but was inhibitory at 250 ng/ml. VT enhancement of H2O2 production was observed as early as 12 h after LPS stimulation. When IFN-gamma was used as the stimulant, VT (25-250 ng/ml) delayed peak H2O2 production. VT (25-250 ng/ml) also markedly decreased NO production in cells activated with LPS or IFN-gamma. Interestingly, VT superinduced TNF-alpha and IL-6 production in LPS-stimulated cells and also elevated TNF-alpha in IFN-gamma stimulated cells. These results suggest that VT can selectively and concurrently upregulate or downregulate critical functions associated with activated macrophages.

  19. Relationship between clinical signs and pulmonary function estimated by the single breath diagram for CO(2) (SBD-CO(2)) in horses with chronic obstructive pulmonary disease.

    PubMed

    Herholz, C; Straub, R; Gerber, V; Wampfler, B; Lüthi, S; Imhof, A; Moens, Y; Busato, A

    2002-03-01

    The pulmonary health of 66 horses was assessed by a clinical examination and simple supplementary diagnostic methods. Single breath diagrams for CO(2) (SBD-CO(2)) and derived lung function indices were used to determine pulmonary function. The clinical signs in different groups were related to the results of the lung function indices derived from the SBD-CO(2). In horses with moderate to severe chronic obstructive pulmonary disease (COPD), a significant relationship was found between the respiratory frequency and the ratio of Bohr's dead space to the tidal volume (VD(Bohr)/VT), and between the physiological dead space/tidal volume ratio (VD(phys)/VT) and the ratio of the alveolar dead space to the alveolar tidal volume (VD(alv)/VT(alv)), but no significant associations were found between the arterial oxygen tension (P(a)O(2)) and lung function indices derived from the SBD-CO(2). The occurrence of cough, the viscosity of tracheobronchial mucus and the amount of polynuclear neutrophils in tracheobronchial aspirates were significantly related to the expiratory tidal volume (VT), the total expired volume of CO(2) (VCO(2)), VD(Bohr)/VT, VD(phys)/VT and VD(alv)/VT(alv). We conclude that abnormal findings in these clinical parameters indicate a measurable ventilation and perfusion (V(A)/Q) mismatch which is reflected by increases in dead space, VD(Bohr)/VT and VD(phys)/VT as well as VD(alv)/VT(alv). Copyright 2002 Elsevier Science Ltd. All rights reserved.

  20. Correlations between the circadian patterns of body temperature, metabolism and breathing in rats.

    PubMed

    Mortola, Jacopo P

    2007-02-15

    It had been demonstrated previously that the circadian patterns of activity and state of arousal are not essential for the manifestation of the daily patterns of pulmonary ventilation (V(E)), tidal volume (V(T)) and breathing frequency (f). In this study we investigated the extent of the linkage between the circadian pattern of breathing and those of body temperature (T(b)) and metabolic rate (oxygen consumption, V(O2), and carbon dioxide production, V(CO2)). Rats were instrumented for measurements of T(b) (by telemetry), and placed in a chamber for continuous 13-day period of measurement of breathing (by a modification of the barometric methodology), and of V(O2) and V(CO2) (by an open flow method). After the first 4 days in control conditions under a 12 h light:12 h dark (L:D) cycle, a perturbation was introduced on day 4, with an L-phase prolongation of 12 h, and on day 9, with an D-phase prolongation of 12 h. During the control days 1-4, all variables had daily oscillations (higher values in D), in phase with each other. During the perturbations (days 4-13), changes in T(b), V(O2) and V(CO2), averaged over the whole period, correlated significantly better with f than with V(T). Day-by-day X-Y loops indicated that V (E), V(T) and f could lead significantly the changes of T(b), V(O2) and V(CO2), and that these relations changed throughout the perturbation period. In addition, f and V(T) did not change necessarily in phase with each other. It is concluded that neither the oscillation in T(b) nor that in metabolism can be considered the direct cause of the daily oscillation of breathing. Presumably, the circadian pattern of breathing reflects the interplay of the daily patterns of many variables, none acting as the primary guide of the breathing daily rhythm.

  1. Vantage Theory and Linguistic Relativity

    ERIC Educational Resources Information Center

    Allan, Keith

    2010-01-01

    Rob MacLaury's Vantage Theory, VT, models the way in which a cognizer constructs, recalls, uses, and modifies a category in terms of point of view or vantage. Alongside of VT, there is place for the kind of semantic specification found in the lexicon. VT2 [Allan, Keith, 2002. "Vantage theory, VT2, and number." "Language Sciences" 24(5-6), 679-703…

  2. Lack of sensitivity of measurements of Vd/Vt at rest and during exercise in detection of hemodynamically significant pulmonary vascular abnormalities in collagen vascular disease.

    PubMed

    Mohsenifar, Z; Tashkin, D P; Levy, S E; Bjerke, R D; Clements, P J; Furst, D

    1981-05-01

    Wasted ventilation fraction (Vd/Vt) normally declines substantially during exercise in persons without lung disease. Failure of Vd/Vt to decrease during exercise has been reported to be one of the earliest abnormalities in patients with dyspnea caused by pulmonary vaso-occlusive disease, suggesting that measurement of Vd/Vt at rest and during exercise are useful in the diagnosis of pulmonary vascular disorders. We studied pulmonary hemodynamic and Vd/Vt responses to exercise in 11 patients in the supine position with suspected pulmonary vascular involvement caused by progressive systemic sclerosis, systemic lupus erythematosus, or recurrent pulmonary emboli, 10 of whom had dyspnea at rest and/or on exertion. In contrast to previous reports of no change or an increase in Vd/Vt during exercise in patients with pulmonary vascular disease, we found Vd/Vt to decrease significantly during exercise in 8 of 9 patients in whom mean pulmonary artery pressures were abnormally elevated at rest and/or during exercise. Our findings suggest that normal responses of Vd/Vt to exercise do not exclude hemodynamically significant pulmonary vaso-occlusive disease.

  3. Effect of 20-hydroxyecdysone and haemolymph on oogenesis in the ixodid tick Amblyomma hebraeum.

    PubMed

    Seixas, Adriana; Friesen, Kevin J; Kaufman, W Reuben

    2008-07-01

    Earlier work from our laboratory indicated that injection of 20-hydroxyecdysone (20E) into non-vitellogenic female Amblyomma hebraeum ticks stimulates the synthesis of vitellogenin (Vg), but not its uptake into oocytes [Friesen, K., Kaufman, W.R., 2004. Effects of 20-hydroxyecdysone and other hormones on egg development, and identification of a vitellin-binding protein in the ovary of the tick, Amblyomma hebraeum. Journal of Insect Physiology 50, 519-529]. In contrast, Thompson et al. [Thompson, D.M., Khalil, S.M.S., Jeffers, L.A., Ananthapadmanaban, U., Sonenshine, D.E., Mitchell, R.D., Osgood, C.J., Apperson, C.S., Roe, M.R., 2005. In vivo role of 20-hydroxyecdysone in the regulation of the vitellogenin mRNA and egg development in the American dog tick, Dermacentor variabilis (Say). Journal of Insect Physiology 51, 1105-1116] demonstrated that injection of 20E into virgin female Dermacentor variabilis ticks stimulated both vitellogenesis and Vg uptake into oocytes. In addition to the species difference in the two studies there were substantially different methods for injecting 20E. In our earlier work we injected small partially fed ticks after removing them from the host. Thompson et al. injected the females while they remained attached to the host. So in this study we repeated our earlier experiments on A. hebraeum using on-host injection. We also injected 20E into off-host ticks with or without haemolymph collected from engorged ticks (days 2-10 post-engorgement), or from large partially fed mated ticks in the rapid phase of engorgement, to see whether we might detect a 'vitellogenin uptake factor' (VUF) in haemolymph. Off-host injection of 20E (0.45microg/g body weight (bw)) did not induce ovary development beyond that of vehicle-injected controls. But ticks in this study, receiving 20E plus haemolymph from engorged ticks, showed a significant increase in ovary weight beyond that of 20E alone (1.31+/-0.05% bw; 34 for 20E plus haemolymph and 1.03+/-0.05% bw; 25 for 20E alone). However, in normal engorged A. hebraeum, the ovary exceeds 7% bw at the onset of oviposition. As in our earlier work, in this study 20E stimulated Vg-synthesis (3.9+/-0.5mgVt-equivalents/ml) beyond that occurring in vehicle-injected ticks (0.76+/-0.14mgVt-equivalents/ml), and there was a further increase in ticks injected with 20E plus haemolymph from engorged ticks (8.9+/-1.0mgVt-equivalents/ml). On-host injection of 20E alone (6microg20E/g bw) did not produce a statistically significant increase in oocyte length over that of vehicle-injected controls, whereas on-host injection of 20E plus engorged haemolymph resulted in significantly larger oocytes (261+/-57microm) compared to vehicle-injected controls (132+/-11microm), compared to 20E alone (131+/-12microm), or haemolymph alone (124+/-24microm). There was a marked stimulation of Vg-synthesis by 31microg20E/g bw (6.0+/-1.5mgVt-equivalents/ml) compared to vehicle-injected controls (1.02+/-33mgVt-equivalents/ml). Vt accumulation by ovaries was significantly greater in ticks treated with haemolymph (12+/-3microgVt/mg ovary) or 20E plus haemolymph (56+/-26microgVt/mg ovary) compared to vehicle-injected controls (5.1+/-1.5microgVt/mg ovary). There was also a significant effect of 6microg20E/g bw plus engorged haemolymph on ovary weight (1.74+/-0.29% bw) compared to vehicle-injected ticks (0.95+/-0.10% bw), but not compared to ticks injected with 20E alone (1.25+/-0.19% bw). We conclude that at least some of the differences observed between the two laboratories relate to the species difference, and that there is some evidence that the engorged haemolymph of A. hebraeum contains a VUF.

  4. [Study of setting of ventilator volume tidal and airway pressure alarm threshold with continuous extra-sternum heart compression in cardiopulmonary resuscitation].

    PubMed

    Luo, Jian-yu; Wang, Xiao-yuan; Cai, Tian-bin; Jiang, Wen-fang

    2013-02-01

    To investigate the setting of ventilator volume tidal (VT) and airway pressure alarm threshold during cardiopulmonary resuscitation (CPR) by continuous extra-sternum heart compression. Forty cases with respiration and cardiac arrest in the department of critical care medicine were randomly divided into low VT ventilation group and conventional VT group. Both groups were given the volume control mode. In the low VT ventilation group, VT was set on 6 - 7 ml/kg, and high pressure alarm threshold was adjusted to 60 cm H2O by the conventional 40 cm H2O during CPR. In the conventional VT group, VT and high pressure alarm threshold were set at 8 - 12 ml/kg and 40 cm H2O, respectively. Real-time actual VT, peak inspiratory pressure (PIP), and arterial blood gas test, blood lactic acid at 10 minutes and 30 minutes after CPR were observed. At 10 minutes after CPR, in the low VT ventilation group, arterial blood pH, arterial partial pressure of oxygen (PaO2), arterial partial pressure of carbon dioxide (PaCO2), HCO3(-), arterial oxygen saturation (SaO2) and blood lactic acid were better as compared with those in the conventional VT ventilation group (pH: 7.21±0.09 vs. 7.13±0.07, PaO2: 45.35±5.92 mm Hg vs. 40.70±4.70 mm Hg, PaCO2: 57.10±7.59 mm Hg vs. 61.60±5.47 mm Hg, HCO3(-): 18.50±3.50 mmol/L vs. 14.75±2.65 mmol/L, SaO2: 0.796±0.069 vs. 0.699±0.066, blood lactic acid: 7.07±1.60 mmol/L vs. 8.13±1.56 mmol/L, all P<0.05). The success rate of resuscitation in the low VT ventilation group was higher than that of the conventional VT ventilation group (45% vs. 15%, P<0.05), and PIP (cm H2O) of low VT ventilation group was lower than that of the conventional VT group (37.25±7.99 cm H2O vs. 42.70±7.40 cm H2O, P<0.05). In all the patients in both groups barotrauma did not occur. The strategy of low ventilator VT (6 - 7 ml/kg) with appropriate elevation of airway pressure alarm threshold was better than that of conventional ventilation setting, with no increase in incidence of barotraumas during CPR.

  5. Plasma flows in the heliosheath along the Voyager 1 and 2 trajectories due to effects of the 11 yr solar cycle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Provornikova, E.; Opher, M.; Izmodenov, V. V.

    We investigate the role of the 11 yr solar cycle variations in the solar wind (SW) parameters on the flows in the heliosheath using a new three-dimensional time-dependent model of the interaction between the SW and the interstellar medium. For boundary conditions in the model we use realistic time and the latitudinal dependence of the SW parameters obtained from SOHO/SWAN and interplanetary scintillation data for the last two solar cycles (1990-2011). This data set generally agrees with the in situ Ulysses measurements from 1991 to 2009. For the first ∼30 AU of the heliosheath the time-dependent model predicts constant radialmore » flow speeds at Voyager 2 (V2), which is consistent with observations and different from the steady models that show a radial speed decrease of 30%. The model shows that V2 was immersed in SW with speeds of 500-550 km s{sup –1} upstream of the termination shock before 2009 and in wind with upstream speeds of 450-500 km s{sup –1} after 2009. The model also predicts that the radial velocity along the Voyager 1 (V1) trajectory is constant across the heliosheath, contrary to observations. This difference in observations implies that additional effects may be responsible for the different flows at V1 and V2. The model predicts meridional flows (VN) higher than those observed because of the strong bluntness of the heliosphere shape in the N direction in the model. The modeled tangential velocity component (VT) at V2 is smaller than observed. Both VN and VT essentially depend on the shape of the heliopause.« less

  6. [Effect of airway humidification on lung injury induced by mechanical ventilation].

    PubMed

    Song, Junjie; Jiang, Min; Qi, Guiyan; Xie, Yuying; Wang, Huaiquan; Tian, Yonggang; Qu, Jingdong; Zhang, Xiaoming; Li, Haibo

    2014-12-01

    To explore the effect of airway humidification on lung injury as a result of mechanical ventilation with different tidal volume (VT). Twenty-four male Japanese white rabbits were randomly divided into four groups: low VT with airway humidification group, high VT with airway humidification group, low VT and high VT group without humidification, with 6 rabbits in each group. Mechanical ventilation was started after intubation and lasted for 6 hours. Low VT denoted 8 mL/kg, while high VT was 16 mL/kg, fraction of inspired oxygen (FiO₂) denoted 0.40, positive end-expiratory pressure (PEEP) was 0. Temperature at Y piece of circuit in airway humidification groups was monitored and controlled at 40 centigrade. Arterial blood gas analysis, including pH value, arterial partial pressure of oxygen (PaO₂), arterial partial pressure of carbon dioxide (PaCO₂), lung mechanics indexes, including peak airway pressure (P(peak)) and airway resistance (Raw), and lung compliance was measured at 0, 2, 4, 6 hours of mechanical ventilation. The levels of tumor necrosis factor-α (TNF-α) and interleukin-8 (IL-8) in plasma and bronchoalveolar lavage fluid (BALF) were determined by enzyme linked immunosorbent assay (ELISA). The animals were sacrificed at the end of mechanical ventilation. The wet to dry (W/D) ratio of lung tissues was calculated. Histopathologic changes in the lung tissueies were observed with microscope, and lung injury score was calculated. Scanning and transmission electron microscopies were used to examine the integrity of the airway cilia and the tracheal epithelium. Compared with low V(T) group, pH value in high V(T) group was significantly increased, PaCO₂was significantly lowered, and no difference in PaO₂was found. P(peak), Raw, and lung compliance were significantly increased during mechanical ventilation. There were no significant differences in blood gas analysis and lung mechanics indexes between low V(T) with airway humidification group and low V(T) group. Compared with high V(T) group, PaCO₂in high V(T) with airway humidification group was significantly decreased, Ppeak raised obviously, and no difference in pH value, PaO₂, Raw and pulmonary compliance was found. Compared with low V(T) with airway humidification group, no difference in blood gas analysis (PaCO2, mmHg, 1 mmHg=0.133 kPa) was found, but Ppeak (cmH₂O, 1 cmH₂O=0.098 kPa), Raw (cmH₂O), and lung compliance (mL/cmH₂O) were increased significantly in high V(T) with airway humidification group (PaCO₂at 2 hours: 27.96 ± 4.64 vs. 36.08 ± 2.11, 4 hours: 28.62 ± 2.93 vs. 34.55 ± 5.50, 6 hours: 29.33 ± 2.14 vs. 35.01 ± 5.53; Ppeak at 0 hour: 14.34 ± 1.97 vs. 8.84 ± 1.32, 2 hours: 17.33 ± 0.52 vs. 11.17 ± 2.14, 4 hours: 17.83 ± 0.98 vs. 12.67 ± 2.06, 6 hours: 18.67 ± 1.22 vs. 13.50 ± 2.16; Raw at 0 hour: 37.36 ± 5.14 vs. 27.0 5 ± 2.93, 2 hours: 43.94 ± 6.58 vs. 31.95 ± 3.56, 4 hours: 48.04 ± 6.07 vs. 35.24 ± 3.50, 6 hours: 50.33 ± 6.34 vs. 36.66 ± 3.64; pulmonary compliance at 6 hours: 2.28 ± 0.18 vs. 1.86 ± 0.37, all P<0.05). The lung W/D ratio in high VT group was significantly higher than that of the low V(T) group (6.17 ± 2.14 vs. 3.50 ± 1.52, P<0.05). W/D in high V(T) with airway humidification group was higher than that of low V(T) with airway humidification group but without statistically significant difference (5.17 ± 2.14 vs. 3.00 ± 1.10, P>0.05). Microscopic observation showed that cilia were partially detached, adhered and sparse in low V(T) group, while cilia in high V(T) group showed serious detachment and lodging. Remaining cilia were sparse, with lodging, and cellular structure was damaged. Lung tissue pathological injury score in the high V(T) group was significantly higher than that of low V(T) group (6.17 ± 2.14 vs. 3.50 ± 1.52, P<0.05). Cilia density and cellularity were normal in low V(T) with airway humidification group, and no difference in lung tissue pathological injury score was found compared with low V(T) group (3.00 ± 1.10 vs. 3.50 ± 1.52, P>0.05). Cilia were severely detached, adhered and lodging, and cellularity were not obvious in high V(T) with airway humidification group, and lung tissue pathological injury score was elevated significantly than that of the low V(T) with airway humidification group but without statistically significant difference (5.17 ± 2.14 vs. 3.00 ± 1.10, P>0.05). TNF-α and IL-8 concentrations showed no change in plasma and BALF in all groups during ventilation, and no significant difference was found among the groups. Airway humidification can alleviate pathological lung injury, damage of cilia and cellular structure in trachea caused by mechanical ventilation with low and high V(T). High V(T) with humidification can result in serious pulmonary edema.

  7. Vibration therapy in patients with cerebral palsy: a systematic review

    PubMed Central

    Ritzmann, Ramona; Stark, Christina; Krause, Anne

    2018-01-01

    The neurological disorder cerebral palsy (CP) is caused by unprogressive lesions of the immature brain and affects movement, posture, and the musculoskeletal system. Vibration therapy (VT) is increasingly used to reduce the signs and symptoms associated with this developmental disability. The purpose of this narrative review was systematically to appraise published research regarding acute and long-term effects of VT on functional, neuromuscular, and structural parameters. Systematic searches of three electronic databases identified 28 studies that fulfilled the inclusion criteria. Studies were analyzed to determine participant characteristics, VT-treatment protocols, effect on gross motor function (GMF), strength, gait, posture, mobility, spasticity, reflex excitability, muscle tone, mass, and bone strength within this population, and outcome measures used to evaluate effects. The results revealed that one acute session of VT reduces reflex excitability, spasticity, and coordination deficits. Subsequently, VT has a positive effect on the ability to move, manifested for GMF, strength, gait, and mobility in patients with CP. Effects persist up to 30 minutes after VT. Long-term effects of VT manifest as reduced muscle tone and spasticity occurring concomitantly with improved movement ability in regard to GMF, strength, gait, and mobility, as well as increased muscle mass and bone-mineral density. Posture control remained unaffected by VT. In conclusion, the acute and chronic application of VT as a nonpharmacological approach has the potential to ameliorate CP symptoms, achieving functional and structural adaptations associated with significant improvements in daily living. Even though further studies including adult populations validating the neuromuscular mechanisms underlying the aforementioned adaptations should be fostered, growing scientific evidence supports the effectiveness of VT in regard to supplementing conventional treatments (physiotherapy and drugs). Therefore, VT could reduce CP-associated physical disability and sensorimotor handicaps. Goals for patients and their caregivers referring to greater independence and improved safety may be achieved more easily and time efficiently.

  8. Efficacy of the clinical agent VT-1161 against fluconazole-sensitive and -resistant Candida albicans in a murine model of vaginal candidiasis.

    PubMed

    Garvey, E P; Hoekstra, W J; Schotzinger, R J; Sobel, J D; Lilly, E A; Fidel, P L

    2015-09-01

    Vulvovaginal candidiasis (VVC) and recurrent VVC (RVVC) remain major health problems for women. VT-1161, a novel fungal CYP51 inhibitor which has potent antifungal activity against fluconazole-sensitive Candida albicans, retained its in vitro potency (MIC50 of ≤0.015 and MIC90 of 0.12 μg/ml) against 10 clinical isolates from VVC or RVVC patients resistant to fluconazole (MIC50 of 8 and MIC90 of 64 μg/ml). VT-1161 pharmacokinetics in mice displayed a high volume of distribution (1.4 liters/kg), high oral absorption (73%), and a long half-life (>48 h) and showed rapid penetration into vaginal tissue. In a murine model of vaginal candidiasis using fluconazole-sensitive yeast, oral doses as low as 4 mg/kg VT-1161 significantly reduced the fungal burden 1 and 4 days posttreatment (P < 0.0001). Similar VT-1161 efficacy was measured when an isolate highly resistant to fluconazole (MIC of 64 μg/ml) but fully sensitive in vitro to VT-1161 was used. When an isolate partially sensitive to VT-1161 (MIC of 0.12 μg/ml) and moderately resistant to fluconazole (MIC of 8 μg/ml) was used, VT-1161 remained efficacious, whereas fluconazole was efficacious on day 1 but did not sustain efficacy 4 days posttreatment. Both agents were inactive in treating an infection with an isolate that demonstrated weaker potency (MICs of 2 and 64 μg/ml for VT-1161 and fluconazole, respectively). Finally, the plasma concentrations of free VT-1161 were predictive of efficacy when in excess of the in vitro MIC values. These data support the clinical development of VT-1161 as a potentially more efficacious treatment for VVC and RVVC. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  9. Systematic Review of the Indirect Effect of Pneumococcal Conjugate Vaccine Dosing Schedules on Pneumococcal Disease and Colonization

    PubMed Central

    2014-01-01

    Background: To aid decision making for pneumococcal conjugate vaccine (PCV) use in infant national immunization programs, we summarized the indirect effects of PCV on clinical outcomes among nontargeted age groups. Methods: We systematically reviewed the English literature on infant PCV dosing schedules published from 1994 to 2010 (with ad hoc addition of 2011 articles) for outcomes on children >5 years of age and adults including vaccine-type nasopharyngeal carriage (VT-NP), vaccine-type invasive pneumococcal disease (VT-IPD) and syndromic pneumonia. Results: Of 12,980 citations reviewed, we identified 21 VT-IPD, 6 VT-NP and 9 pneumonia studies. Of these 36, 21 (58%) included 3 primary doses plus PCV or pneumococcal polysaccharide vaccine (PPV23) booster schedule (3+1 or 3+PPV23), 5 (14%) 3+0, 9 (25%) 2+1 and 1 (3%) 2+0. Most (95%) were PCV7 studies. Among observational VT-IPD studies, all schedules (2+1, 3+0 and 3+1) demonstrated reductions in incidence among young adult groups. Among syndromic pneumonia observational studies (2+1, 3+0 and 3+1), only 3+1 schedules showed significant indirect impact. Of 2 VT-NP controlled trials (3+0 and 3+1) and 3 VT-NP observational studies (2+1, 3+1 and 3+PPV23), 3+1 and 3+PPV23 schedules showed significant indirect effect. The 1 study to directly compare between schedules was a VT-NP study (2+0 vs. 2+1), which found no indirect effect on older siblings and parents of vaccinated children with either schedule. Conclusions: Indirect benefit of a 3+1 infant PCV dosing schedule has been demonstrated for VT-IPD, VT-NP and syndromic pneumonia; 2+1 and 3+0 schedules have demonstrated indirect effect only for VT-IPD. The choice of optimal infant PCV schedule is limited by data paucity on indirect effects, especially a lack of head-to-head studies and studies of PCV10 and PCV13. PMID:24336058

  10. Comparison of efficacies of bovine immune colostral antibody and each immunoglobulin class against verotoxin 2, flagellum and somatic cells of Escherichia coli O157:H7 in mice.

    PubMed

    Seita, Tetsurou; Kuribayashi, Takashi; Honjo, Toshio; Yamamoto, Shizuo

    2013-04-01

    The efficacy of bovine immune colostral (colostral) antibodies against verotoxin (VT) 2, flagellum and somatic cells of Escherichia coli (E. coli) O157:H7 in mice was determined. Three major immunoglobulin (Ig) classes were isolated from the colostral antibody against VT2 by affinity chromatography and were used for estimation. Mice inoculated with VT2 were administered each Ig class from the colostral antibody, colostral antibody (colostral whey containing antibody) or serum antibody against VT2 at 1 hour after VT2 inoculation. All control mice (20/20) died after administration of sterilized saline instead of the colostral antibody. The survival rate was 93.3% (14/15) after administration of S-IgA or IgM antibody, or colostral antibody. Survival rates for IgG antibody and serum antibody administration were 80% (12/15) and 60% (9/15), respectively. Serum concentrations of VT2, which was absorbed from the small intestine in mice after administration of VT2 and colostral antibody, were measured by fluorescence enzyme immunoassay (FEIA). Serum concentrations of VT2 after administration of colostral antibody were lower than those after administration of sterilized saline. Mice inoculated with VT2-producing E. coli 157:H7 were administered anti-flagellum or anti-somatic colostral antibodies. Survival rates for E. coli O157:H7-infected mice administered the anti-flagellum and anti-somatic colostral antibodies were 52.4% (11/21) and 22.2% (4/18), respectively. Furthermore, survival rates increased to 89.5% (17/19) with combined administration of anti-flagellum and anti-VT2 colostral antibodies. These results suggest that colostral antibodies against VT2, flagellum and somatic cells are effective against E. coli O157:H7 infection. Copyright © 2012. Published by Elsevier B.V.

  11. Failure of third-generation implantable cardioverter defibrillators to abort shock therapy for nonsustained ventricular tachycardia due to shortcomings of the VF confirmation algorithm.

    PubMed

    Grimm, W; Menz, V; Hoffmann, J; Maisch, B

    1998-04-01

    Unnecessary shocks by ICDs for rhythms other than sustained VT or VF have been described as the most frequent adverse event in ICD patients. To avoid unnecessary shocks for self-terminating arrhythmias, the third-generation Jewel PCD defibrillators 7202, 7219, and 7220 Plus use a specially designed VF confirmation algorithm after charge end. The purpose of this study was to determine the ability of this VF confirmation algorithm to recognize nonsustained VT, and to analyze the reasons for failure of the PCD device to abort shock therapy for nonsustained VT despite use of this VF confirmation algorithm. Analysis of stored electrograms of electrical events triggering high voltage capacitor charging in the programmed VF zone of the device showed 36 spontaneous episodes of nonsustained VT (227 +/- 21 beats/min) during 18 +/- 7 months follow-up in 15 patients who had a Jewel PCD implanted at our hospital. Intracardiac electrogram recordings and simultaneously retrieved marker channels demonstrated that the ICD shock was appropriately aborted according to the VF confirmation algorithm in 24 (67%) of 36 episodes of nonsustained VT. Twelve episodes (33%) of nonsustained VT, however, were followed by spontaneous ICD shock in 6 (40%) of the 15 study patients. The only reason for all 12 shocks for sustained VT was the inability of the device to recognize the absence of VT after charge end due to shortcomings of the VF confirmation algorithm: 11 of the 12 shocks for nonsustained VT were triggered by the occurrence of paced beats during the VF confirmation period and 1 shock for nonsustained VT was triggered by the occurrence of 2 premature beats after charge end. Thus, better VF confirmation algorithms need to be incorporated in future PCD devices to avoid unnecessary shocks for nonsustained VT.

  12. Rhythms and outcomes of adult in-hospital cardiac arrest.

    PubMed

    Meaney, Peter A; Nadkarni, Vinay M; Kern, Karl B; Indik, Julia H; Halperin, Henry R; Berg, Robert A

    2010-01-01

    To determine the relationship of electrocardiographic rhythm during cardiac arrest with survival outcomes. Prospective, observational study. Total of 411 hospitals in the National Registry of Cardiopulmonary Resuscitation. Total of 51,919 adult patients with pulseless cardiac arrests from April 1999 to July 2005. Registry data collected included first documented rhythm, patient demographics, pre-event data, event data, and survival and neurologic outcome data. Of 51,919 indexed cardiac arrests, first documented pulseless rhythm was ventricular tachycardia (VT) in 3810 (7%), ventricular fibrillation (VF) in 8718 (17%), pulseless electrical activity (PEA) in 19,262 (37%) and asystole 20,129 (39%). Subsequent VT/VF (that is, VT or VF occurring during resuscitation for PEA or asystole) occurred in 5154 (27%), with first documented rhythm of PEA and 4988 (25%) with asystole. Survival to hospital discharge rate was not different between those with first documented VF and VT (37% each, adjusted odds ratio [OR]) 1.08; 95% confidence interval [CI] 0.95-1.23). Survival to hospital discharge was slightly more likely after PEA than asystole (12% vs. 11%, adjusted OR 1.1; 95% CI 1.00-1.18), Survival to discharge was substantially more likely after first documented VT/VF than PEA/asystole (adjusted OR 1.68; 95% CI 1.55-1.82). Survival to discharge was also more likely after PEA/asystole without subsequent VT/VF compared with PEA/asystole with subsequent VT/VF (14% vs. 7% for PEA without vs. with subsequent VT/VF; 12% vs. 8% for asystole without vs. with subsequent VT/VF; adjusted OR 1.60; 95% CI, 1.44-1.80). Survival to hospital discharge was substantially more likely when the first documented rhythm was shockable rather than nonshockable, and slightly more likely after PEA than asystole. Survival to hospital discharge was less likely following PEA/asystole with subsequent VT/VF compared to PEA/asystole without subsequent VT/VF.

  13. Early Ventricular Tachycardia or Fibrillation in Patients With ST Elevation Myocardial Infarction Undergoing Primary Percutaneous Coronary Intervention and Impact on Mortality and Stent Thrombosis (from the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction Trial).

    PubMed

    Kosmidou, Ioanna; Embacher, Monica; McAndrew, Thomas; Dizon, José M; Mehran, Roxana; Ben-Yehuda, Ori; Mintz, Gary S; Stone, Gregg W

    2017-11-15

    The prevalence and impact of early ventricular arrhythmias (ventricular tachycardia [VT]/ventricular fibrillation [VF]) occurring before mechanical revascularization for acute ST segment elevation myocardial infarction (STEMI) treated with percutaneous coronary intervention are poorly understood. We sought to investigate the association between early VT/VF and long-term clinical outcomes using data from the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction trial. Among 3,602 patients with STEMI, 108 patients (3.0%) had early VT/VF. Baseline clinical characteristics were similar in patients with versus without early VT/VF. Patients with early VT/VF had shorter symptom-to-balloon times and lower left ventricular ejection fraction and underwent more frequent thrombectomy compared with patients without early VT/VF. Adjusted 3-year rates of all-cause death (15.7% vs 6.5%; adjusted hazard ratio 2.62, 95% confidence interval 1.48 to 4.61, p <0.001) and stent thrombosis (13.7% vs 5.7%; adjusted hazard ratio 2.74, 95% confidence interval 1.52 to 4.93, p <0.001) were significantly higher in patients with early VT/VF compared with patients without early VT/VF. In conclusion, in the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction trial, VT/VF occurring before coronary angiography and revascularization in patients with STEMI was strongly associated with increased 3-year rates of death and stent thrombosis. Further investigation into the mechanisms underlying the increased risk of early stent thrombosis in patients with early VT/VF is required. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. The risk of venous thrombosis in women over 50 years old using oral contraception or postmenopausal hormone therapy.

    PubMed

    Roach, R E J; Lijfering, W M; Helmerhorst, F M; Cannegieter, S C; Rosendaal, F R; van Hylckama Vlieg, A

    2013-01-01

    Oral contraception (OC) and postmenopausal hormone therapy (HT) can be used to alleviate menopausal symptoms. However, the risk of venous thrombosis (VT) associated with OC use in women over 50 years old has never been assessed and the two preparations have not been directly compared. To determine and compare the risk of VT associated with OC and HT use. From a large case-control study, 2550 women aged over 50 years old, 1082 patients with a first VT and 1468 controls, were included. Odds ratios (ORs) and 95% confidence intervals for VT were calculated for OC-users (164 patients and 54 controls) and HT-users (88 patients and 102 controls) compared with non-hormone users (823 patients and 1304 controls). OC-users had a 6.3-fold (4.6-9.8) increased risk of VT. This ranged from 5.4 (3.3-8.9) for preparations containing levonorgestrel to 10.2 (4.8-21.7) for desogestrel. The VT-risk associated with oral HT use was 4.0 (1.8-8.2) for conjugated equine estrogen combined with medroxyprogesterone acetate and 3.9 (1.5-10.7) for micronized estradiol combined with norethisterone acetate. Non-oral HT did not increase the risk of VT: OR 1.1 (0.6-1.8). Relative risk estimates were further increased in hormone users with factor V Leiden, prothrombin G20210A or blood group non-O and hormone users with a family history of VT. In this study, non-oral HT seemed to be the safest hormonal preparation in women over 50 years old. OC use increased the VT risk the most, especially in women with inherited thrombophilia or a family history of VT. © 2012 International Society on Thrombosis and Haemostasis.

  15. DNA Inversion on Conjugative Plasmid pVT745

    PubMed Central

    Chen, Jinbiao; Leblanc, Donald J.; Galli, Dominique M.

    2002-01-01

    Plasmid pVT745 from Actinobacillus actinomycetemcomitans strain VT745 can be transferred to other A. actinomycetemcomitans strains at a frequency of 10−6. Screening of transconjugants revealed that the DNA of pDMG21A, a pVT745 derivative containing a kanamycin resistance gene, displayed a structural rearrangement after transfer. A 9-kb segment on the plasmid had switched orientation. The inversion was independent of RecA and required the activity of the pVT745-encoded site-specific recombinase. This recombinase, termed Inv, was highly homologous to invertases of the Din family. Two recombination sites of 22 bp, which are arranged in opposite orientation and which function as DNA crossover sequences, were identified on pVT745. One of the sites was located adjacent to the 5′ end of the invertase gene, inv. Inversion of the 9-kb segment on pVT745 derivatives has been observed in all A. actinomycetemcomitans strains tested except for the original host, VT745. This would suggest that a host factor that is either inactive or absent in VT745 is required for efficient recombination. Inactivation of the invertase in the donor strain resulted in a 1,000-fold increase in the number of transconjugants upon plasmid transfer. It is proposed that an activated invertase causes the immediate loss of the plasmid in most recipient cells after mating. No biological role has been associated with the invertase as of yet. PMID:12374826

  16. Purification of vitellin and dynamics of vitellogenesis in the parthenogenetic tick Haemaphysalis longicornis (Acari: Ixodidae).

    PubMed

    Yang, Xiaolong; Yu, Zhijun; He, Yanjie; Xu, Xiaoli; Gao, Zhihua; Wang, Hui; Chen, Jie; Liu, Jingze

    2015-03-01

    Vitellin (Vt) was purified from eggs of parthenogenetic bush tick Haemaphysalis longicornis by gel filtration and ion exchange chromatography. Our results revealed that only one single Vt existed in parthenogenetic bush tick, and the purified Vt was proved to be a hemoglycolipoprotein consisting of nine polypeptides with molecular weights of 203, 147, 126, 82, 74, 70, 61, 47 and 31 kDa, respectively. Polyclonal antibody and monoclonal antibody against Vt were produced using the purified Vt. The change in vitellogenin (Vg) and Vt levels over time of the parthenogenetic H. longicornis was established, and the Vg content in haemolymph and Vt in ovary at different feeding or engorgement statuses was also determined using a double antibody sandwich enzyme-linked immunosorbent assay. The Vg level in haemolymph was distinctly increased on the day of engorgement (1.785 mg/mL) and continued to increase until 2nd day post-engorgement (5.611 mg/mL). There was a slight decrease in Vg level after 4 days of engorgement, and a second peak was observed on day 2 post-oviposition (10.774 mg/mL). Subsequently, Vg content continuously decreased and reached a low level on the 10th day post-oviposition. The Vt content in ovary continuously increased once the female reached its critical weight (0.024 mg per female), and reached the maximum level on day 2 post-oviposition (1.942 mg per female). Afterwards, Vt content rapidly decreased.

  17. Occurrence of verotoxin-producing Escherichia coli in dairy heifers grazing an irrigated pasture.

    PubMed

    Thran, B H; Hussein, H S; Hall, M R; Khaiboullina, S F

    2001-02-28

    Verotoxin-producing Escherichia coli (VTEC) produce one or two toxins known as VT1 and VT2. These toxins have been associated with several human illnesses. Dairy cattle harboring VTEC represent a potential health hazard because they enter the food chain as ground beef. The objective of this study was to assess the occurrence of VTEC in dairy heifers. A total of 91 fecal samples were rectally collected during four periods (spring, summer, fall, and winter of 1999) from 23 heifers. A random sample (n=530) of potential VTEC isolates were tested for verotoxicity and were screened by the polymerase chain reaction (PCR) for presence or absence of VT1 and/or VT2 genes. Thirteen isolates from two heifers (from the winter collection) were verotoxic and were confirmed as E. coli. VTEC were only detected during winter with an occurrence rate of 9.5%. Using PCR, five isolates had the VT1 gene while the remaining eight had the VT2 gene. The sequence and expression of VT1 and VT2 genes were confirmed. No E. coli O157:H7 was detected, but serotyping revealed that the five VT1-positive isolates were O26:NM (a non-motile strain of O26). The remaining eight isolates were untypeable. Identification of VTEC-positive cattle before slaughter is a critical step in any on-farm strategy to minimize the risk of beef contamination with such pathogens.

  18. Genetics of Venous Thrombosis: Insights from a New Genome Wide Association Study

    PubMed Central

    Germain, Marine; Saut, Noémie; Greliche, Nicolas; Dina, Christian; Lambert, Jean-Charles; Perret, Claire; Cohen, William; Oudot-Mellakh, Tiphaine; Antoni, Guillemette; Alessi, Marie-Christine; Zelenika, Diana; Cambien, François; Tiret, Laurence; Bertrand, Marion; Dupuy, Anne-Marie; Letenneur, Luc; Lathrop, Mark; Emmerich, Joseph; Amouyel, Philippe; Trégouët, David-Alexandre; Morange, Pierre-Emmanuel

    2011-01-01

    Background Venous Thrombosis (VT) is a common multifactorial disease associated with a major public health burden. Genetics factors are known to contribute to the susceptibility of the disease but how many genes are involved and their contribution to VT risk still remain obscure. We aimed to identify genetic variants associated with VT risk. Methodology/Principal Findings We conducted a genome-wide association study (GWAS) based on 551,141 SNPs genotyped in 1,542 cases and 1,110 controls. Twelve SNPs reached the genome-wide significance level of 2.0×10−8 and encompassed four known VT-associated loci, ABO, F5, F11 and FGG. By means of haplotype analyses, we also provided novel arguments in favor of a role of HIVEP1, PROCR and STAB2, three loci recently hypothesized to participate in the susceptibility to VT. However, no novel VT-associated loci came out of our GWAS. Using a recently proposed statistical methodology, we also showed that common variants could explain about 35% of the genetic variance underlying VT susceptibility among which 3% could be attributable to the main identified VT loci. This analysis additionally suggested that the common variants left to be identified are not uniformly distributed across the genome and that chromosome 20, itself, could contribute to ∼7% of the total genetic variance. Conclusions/Significance This study might also provide a valuable source of information to expand our understanding of biological mechanisms regulating quantitative biomarkers for VT. PMID:21980494

  19. Effect of Wheelchair Frame Material on Users' Mechanical Work and Transmitted Vibration

    PubMed Central

    Aissaoui, Rachid

    2014-01-01

    Wheelchair propulsion exposes the user to a high risk of shoulder injury and to whole-body vibration that exceeds recommendations of ISO 2631-1:1997. Reducing the mechanical work required to travel a given distance (WN-WPM, weight-normalized work-per-meter) can help reduce the risk of shoulder injury, while reducing the vibration transmissibility (VT) of the wheelchair frame can reduce whole-body vibration. New materials such as titanium and carbon are used in today's wheelchairs and are advertised to improve both parameters, but current knowledge on this matter is limited. In this study, WN-WPM and VT were measured simultaneously and compared between six folding wheelchairs (1 titanium, 1 carbon, and 4 aluminium). Ten able-bodied users propelled the six wheelchairs on three ground surfaces. Although no significant difference of WN-WPM was found between wheelchairs (P < 0.1), significant differences of VT were found (P < 0.05). The carbon wheelchair had the lowest VT. Contrarily to current belief, the titanium wheelchair VT was similar to aluminium wheelchairs. A negative correlation between VT and WN-WPM was found, which means that reducing VT may be at the expense of increasing WN-WPM. Based on our results, use of carbon in wheelchair construction seems promising to reduce VT without increasing WN-WPM. PMID:25276802

  20. Anti-Inflammatory Effects of Vitis thunbergii var. taiwaniana on Knee Damage Associated with Arthritis

    PubMed Central

    Tsai, Ching-Fent; Wang, Kun-Teng; Chen, Lih-Geeng; Lee, Chia-Jung; Tseng, Sung-Hui

    2014-01-01

    Abstract Vitis thunbergii Sieb. et Zucc. var. taiwaniana Lu (VT) is an indigenous plant in Taiwan that is traditionally used for promoting joint health. In this study, we used in vitro primary human chondrocytes (PHCs) and two in vivo animal models to evaluate the anti-inflammatory effects of VT on arthritis. Results showed that the water extract of the stems and roots from VT (VT-SR) was rich in flavones and phenols with 1.1 mg/g of resveratrol, 6.7 mg/g of hopeaphenol, and 5.1 mg/g of (+)-ɛ-viniferin. VT-SR significantly scavenged DPPH radicals and inhibited prostaglandin E2 (PGE2) production in lipopolysaccharide (LPS)-induced PHCs without exhibiting significant cytotoxicity. In in vivo models, the VT-SR (500 mg/kg) significantly decreased serum PGE2 and knee 2-18F-fluoro-2-deoxy-D-glucose (18F-FDG) levels in LPS-induced acute inflammatory arthritis in rabbits. In addition, dietary supplementation with VT-SR for 28 days significantly alleviated type II collagenase-induced rat osteoarthritis with improvements in weight bearing and range of motion tests. In conclusion, our results suggest that the VT-SR is a good candidate for developing dietary supplements to prevent joint deterioration and inhibit inflammation. PMID:24720858

  1. Terror Attacks Increase the Risk of Vascular Injuries

    PubMed Central

    Heldenberg, Eitan; Givon, Adi; Simon, Daniel; Bass, Arie; Almogy, Gidon; Peleg, Kobi

    2014-01-01

    Objectives: Extensive literature exists about military trauma as opposed to the very limited literature regarding terror-related civilian trauma. However, terror-related vascular trauma (VT), as a unique type of injury, is yet to be addressed. Methods: A retrospective analysis of the Israeli National Trauma Registry was performed. All patients in the registry from 09/2000 to 12/2005 were included. The subgroup of patients with documented VT (N = 1,545) was analyzed and further subdivided into those suffering from terror-related vascular trauma (TVT) and non-terror-related vascular trauma (NTVT). Both groups were analyzed according to mechanism of trauma, type and severity of injury and treatment. Results: Out of 2,446 terror-related trauma admissions, 243 sustained TVT (9.9%) compared to 1302 VT patients from non-terror trauma (1.1%). TVT injuries tend to be more complex and most patients were operated on. Intensive care unit admissions and hospital length of stay was higher in the TVT group. Penetrating trauma was the prominent cause of injury among the TVT group. TVT group had a higher proportion of patients with severe injuries (ISS ≥ 16) and mortality. Thorax injuries were more frequent in the TVT group. Extremity injuries were the most prevalent vascular injuries in both groups; however NTVT group had more upper extremity injuries, while the TVT group had significantly much lower extremity injuries. Conclusion: Vascular injuries are remarkably more common among terror attack victims than among non-terror trauma victims and the injuries of terror casualties tend to be more complex. The presence of a vascular surgeon will ensure a comprehensive clinical care. PMID:24910849

  2. Terror attacks increase the risk of vascular injuries.

    PubMed

    Heldenberg, Eitan; Givon, Adi; Simon, Daniel; Bass, Arie; Almogy, Gidon; Peleg, Kobi

    2014-01-01

    Extensive literature exists about military trauma as opposed to the very limited literature regarding terror-related civilian trauma. However, terror-related vascular trauma (VT), as a unique type of injury, is yet to be addressed. A retrospective analysis of the Israeli National Trauma Registry was performed. All patients in the registry from 09/2000 to 12/2005 were included. The subgroup of patients with documented VT (N = 1,545) was analyzed and further subdivided into those suffering from terror-related vascular trauma (TVT) and non-terror-related vascular trauma (NTVT). Both groups were analyzed according to mechanism of trauma, type and severity of injury and treatment. Out of 2,446 terror-related trauma admissions, 243 sustained TVT (9.9%) compared to 1302 VT patients from non-terror trauma (1.1%). TVT injuries tend to be more complex and most patients were operated on. Intensive care unit admissions and hospital length of stay was higher in the TVT group. Penetrating trauma was the prominent cause of injury among the TVT group. TVT group had a higher proportion of patients with severe injuries (ISS ≥ 16) and mortality. Thorax injuries were more frequent in the TVT group. Extremity injuries were the most prevalent vascular injuries in both groups; however NTVT group had more upper extremity injuries, while the TVT group had significantly much lower extremity injuries. Vascular injuries are remarkably more common among terror attack victims than among non-terror trauma victims and the injuries of terror casualties tend to be more complex. The presence of a vascular surgeon will ensure a comprehensive clinical care.

  3. The endophyte Verticillium Vt305 protects cauliflower against Verticillium wilt.

    PubMed

    Tyvaert, L; França, S C; Debode, J; Höfte, M

    2014-06-01

    To investigate the interaction between cauliflower and the isolate VerticilliumVt305, obtained from a field suppressive to Verticillium wilt of cauliflower, and to evaluate the ability of VerticilliumVt305 to control Verticillium wilt of cauliflower caused by V. longisporum. Single and combined inoculations of VerticilliumVt305 and V. longisporum were performed on cauliflower seedlings. Symptom development was evaluated, and fungal colonization was measured in the roots, hypocotyl and stem with real-time PCR. No symptoms were observed after single inoculation of VerticilliumVt305, although it colonized the plant tissues. Pre-inoculation of VerticilliumVt305 reduced symptom development and colonization of plant tissues by V. longisporum. VerticilliumVt305 is an endophyte on cauliflower plants and showed effective biological control of V. longisporum in controlled conditions. This work can contribute to the development of a sustainable control measure of V. longisporum in Brassicaceae hosts, which is currently not available. Additionally, this study provides evidence for the different roles of Verticillium species present in the agro-ecosystem. © 2014 The Society for Applied Microbiology.

  4. Prevalence and prognosis of ventricular tachycardia/ventricular fibrillation in patients with post-infarction left ventricular aneurysm: Analysis of 575 cases.

    PubMed

    Ning, Xiaohui; Ye, Xuerui; Si, Yanhua; Yang, Zihe; Zhao, Yunzi; Sun, Qi; Chen, Ruohan; Tang, Min; Chen, Keping; Zhang, Xiaoli; Zhang, Shu

    2018-03-21

    We investigated the prevalence of ventricular tachycardia/ventricular fibrillation (VT/VF) in Post-infarction left ventricular aneurysm (PI-LVA) patients and analyze clinical outcomes in patients presenting with VT/VF. 575 PI-LVA patients were enrolled and investigated by logistic regression analysis. Patients with VT/VF were followed up, the composite primary endpoint was cardiac death and appropriate ICD/external shocks. The incidence of sustained VT/VF was 11%. Logistical regression analysis showed male gender, enlarged LV end diastolic diameter (LVEDD) and higher NYHA class were correlated with VT/VF development. During follow up of 46 ± 15 months, 19 out of 62(31%) patients reached study end point. Multivariate Cox regression analysis revealed that enlarged LVEDD and moderate/severe mitral regurgitation (MR) were independently predictive of clinical outcome. Male gender, enlarged LVEDD and higher NYHA class associated with risk of sustained VT/VF in PI-LVA patients. Among VT/VF positive patients, enlarged LVEDD and moderate/severe MR independently predicted poor clinical prognosis. Copyright © 2018. Published by Elsevier Inc.

  5. 23. Engine room, as seen from starboard side near ladderway ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. Engine room, as seen from starboard side near ladderway from main (promenade) deck. At left is hot well for main engine, at the sides of which are two reciprocating boiler feedwater pumps. Behind the hot well is the condenser and the foot of one of the legs supporting the walking beam A-frame. Hot well and condenser rest on a large bed (painted black) which runs the length of the engine. In the right foreground is water pump for trim tanks. - Steamboat TICONDEROGA, Shelburne Museum Route 7, Shelburne, Chittenden County, VT

  6. EOS-AM1 Nickel Hydrogen Cell Interim Life Test Report

    NASA Technical Reports Server (NTRS)

    Bennett, C. W.; Keys, D. J.; Rao, G. M.; Wannemacher, H. E.; Vaidyanathan, H.

    1997-01-01

    This paper reports the interim results of the Earth Observing System AM-1 project (EOS-AM-1) nickel hydrogen cell life test being conducted under contract to National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) at the Lockheed Martin Missiles and Space (LMMS) facility in East Windsor, NJ; and at COMSAT Labs., Clarksburg, MD. The purpose of the tests is to verify that the EOS-AM-l cell design can meet five years of real-time Low Earth Orbit (LEO) cycling. The tests include both real-time LEO and accelerated stress tests. At LMMS, the first real-time LEO simulated 99 minute orbital cycle started on February 7, 1994 and the test has been running continuously since that time, with 13000 LEO cycles completed as of September 2, 1996. Each cycle consists of a 64 minute charge (VT at 1.507 volts per cell, 1.06 C/D ratio, followed by 0.6 ampere trickle charge) and a 35 minute constant power discharge at 177 watts (22.5% DOD). At COMSAT, the accelerated stress test consists of 90 minute orbital cycles at 60% DOD with a 30 minute discharge at 60 amperes and a 60 minute charge at 40 ampercs (VT at 1.54 volts per cell to 1.09 C/D ratio, followed by 0.6 ampere trickle charge). The real-time LEO life test battery consists of seven, 50AH (nameplate rating) Eagle-Picher, Inc. (EPI) Mantech cells manufactured into three, 3-cell pack assemblies (there are two place holder cells that are not part of the life test electrical circuit). The test pack is configured to simulate the conductive thermal design of the spacecraft battely, including: conductive aluminum sleeves, 3-cell pack aluminum baseplate, and honeycomb panel all mounted to a liquid (-5 C) cold plate. The entire assembly is located in a thermal chamber operating at +3 C. The accelerated stress test unit consists of five cells mounted in machined aluminum test sleeves and is operating at +10 C. The real-time LEO life test battery has met all performance requirements through the first 13,000 cycles, including: end of charge and discharge cell voltages and voltage gradients; end of chalge and discharge cell pressures; within cell and between cell temperature gradients; discharge capacity; current and power levels; and all chalge parameters. The accelerated stress test battely has completed over 5900 cycles as of 9/11/96. This paper reports both battery performances as a function of cycle life, with individual cell performance comparisons repolted for selected cycles in both tests.

  7. Hemodynamic deterioration precedes onset of ventricular tachyarrhythmia after Heartmate II implantation.

    PubMed

    Yaksh, Ameeta; Kik, Charles; Knops, Paul; Zwiers, Korinne; van Ettinger, Maarten J B; Manintveld, Olivier C; de Wijs, Marcel C J; van der Kemp, Peter; Bogers, Ad J J C; de Groot, Natasja M S

    2016-07-08

    Early postoperative ventricular tachyarrhythmia (PoVT) after left ventricular assist device (LVAD) implantation are common and associated with higher mortality-rates. At present, there is no data on initiation of these PoVT and the role of alterations in cardiac hemodynamics. A LVAD was implanted in a patient with end-stage heart failure due to a ischemic cardiomyopathy. Alterations in cardiac rhythm and hemodynamics preceding PoVT-episodes during the first five postoperative days were examined by using continuous recordings of cardiac rhythm and various hemodynamic parameters. All PoVT (N=120) were monomorphic, most often preceded by short-long-short-sequences or regular SR and initiated by ventricular runs. Prior to PoVT, mean arterial pressure decreased; heart rate and ST-segments deviations increased. PoVT are caused by different underlying electrophysiological mechanisms. Yet, they are all monomorphic and preceded by hemodynamic deterioration due to myocardial ischemia.

  8. Relationship among eye and muzzle temperatures measured using digital infrared thermal imaging and vaginal and rectal temperatures in hair sheep and cattle.

    PubMed

    George, W D; Godfrey, R W; Ketring, R C; Vinson, M C; Willard, S T

    2014-11-01

    Digital infrared thermal imaging (DITI) using a thermal camera has potential to be a useful tool for the production animal industry. Thermography has been used in both humans and a wide range of animal species to measure body temperature as a method to detect injury or inflammation. The objective of these experiments was to compare the temperature of the eye (EYE) or muzzle (MUZ) measured using DITI to vaginal (VT) and rectal temperature (RT) as measures of core body temperature in hair sheep and beef cattle. In Exp.1 EYE, VT and RT were measured in lactating, multiparous hair sheep ewes (St. Croix White, n = 10, and Dorper × St. Croix White, n = 10) in a non-febrile state 5 times over a 48-h period. Data loggers were used to measure VT and a digital veterinary thermometer was used to measure RT. There was a high correlation (P < 0.001) between VT and RT (r = 0.95), EYE and RT (r = 0.76) and EYE and VT (r = 0.77). In Exp. 2 EYE, MUZ, VT and RT were measured in multiparous, lactating ewes (St. Croix White, n = 2, and Barbados Blackbelly, n = 12) at -12, -1, 0, 1, 2, 3, 4, 6, 12, 24, 36, and 48 h after being administered lipopolysaccharide (LPS; n = 7; 0.2 µg/kg BW, i.v.) or saline (n = 7; 0.5 mL, i.v.). Data loggers were used to measure VT and a digital veterinary thermometer was used to measure RT. When data were combined across treatments (LPS and saline) there was a high correlation (P < 0.001) between VT and RT (r = 0.96), EYE and RT (r = 0.82), MUZ and RT (r = 0.72), and EYE and VT (r = 0.93). In Exp. 3 EYE, MUZ, VT and RT were measured in multiparous, non-lactating, pregnant Senepol cattle (n = 44) between 0900 and 1200 h on a single day. A digital veterinary thermometer was used to measure both VT and RT. There was a high correlation (P < 0.001) between VT and RT (r = 0.78), a moderate correlation (P < 0.001) between VT and EYE (r = 0.52), RT and EYE (r = 0.58) and EYE and MUZ (r = 0.48). There was no correlation (P > 0.10) between RT or VT and MUZ. The findings of these three studies indicate that temperature of the eye, measured using DITI, can be used as an indicator of core body temperature in hair sheep and beef cattle as an alternative to using vaginal or rectal temperature.

  9. Volume Transmission in Central Dopamine and Noradrenaline Neurons and Its Astroglial Targets.

    PubMed

    Fuxe, Kjell; Agnati, Luigi F; Marcoli, Manuela; Borroto-Escuela, Dasiel O

    2015-12-01

    Already in the 1960s the architecture and pharmacology of the brainstem dopamine (DA) and noradrenaline (NA) neurons with formation of vast numbers of DA and NA terminal plexa of the central nervous system (CNS) indicated that they may not only communicate via synaptic transmission. In the 1980s the theory of volume transmission (VT) was introduced as a major communication together with synaptic transmission in the CNS. VT is an extracellular and cerebrospinal fluid transmission of chemical signals like transmitters, modulators etc. moving along energy gradients making diffusion and flow of VT signals possible. VT interacts with synaptic transmission mainly through direct receptor-receptor interactions in synaptic and extrasynaptic heteroreceptor complexes and their signaling cascades. The DA and NA neurons are specialized for extrasynaptic VT at the soma-dendrtitic and terminal level. The catecholamines released target multiple DA and adrenergic subtypes on nerve cells, astroglia and microglia which are the major cell components of the trophic units building up the neural-glial networks of the CNS. DA and NA VT can modulate not only the strength of synaptic transmission but also the VT signaling of the astroglia and microglia of high relevance for neuron-glia interactions. The catecholamine VT targeting astroglia can modulate the fundamental functions of astroglia observed in neuroenergetics, in the Glymphatic system, in the central renin-angiotensin system and in the production of long-distance calcium waves. Also the astrocytic and microglial DA and adrenergic receptor subtypes mediating DA and NA VT can be significant drug targets in neurological and psychiatric disease.

  10. Response of sap flow to environmental factors in the headwater catchment of Miyun Reservoir in subhumid North China

    NASA Astrophysics Data System (ADS)

    Tie, Qiang; Hu, Hongchang; Tian, Fuqiang; Liu, Yaping; Xu, Ran

    2015-04-01

    Since the headwater catchment of Miyun Reservoir is the main drinking water conservation area of Beijing, its water cycle is of importance for the regional water resource. Transpiration is an important component of water cycle, which can be estimated by sap flow. In this study, the dynamics of sap flow and its response to environmental factors and relationship with leaf area index (LAI) were analyzed. The field study was conducted in the Xitaizi Experimental Catchment, located in the headwater catchment of Miyun Reservoir in subhumid North China. The Aspen (Populus davidiana) and Epinette (Larix gmelinii) are the two dominant tree species. Sap flow in 15 Aspen (Populus davidiana) trees was monitored using thermal dissipation probes (TDP) during the growing season of 2013 and 2014, and sap flow in another 3 Epinette (Larix gmelinii) trees was also monitored during September and October in 2014 for comparative analysis. Physiological and biometric parameters of the selected trees and the environmental factors, including meteorological variables, soil moisture content and groundwater table depth were measured. Vapor pressure deficit (VPD), variable of transpiration (VT) and reference crop evapotranspiration (ET0) were calculated using the measured environmental factors. The LAI, which is used to characterize phenophase, was calculated using the Moderate Resolution Imaging Spectroradiometer (MODIS) LAI product (MCD15A3). Correlation analysis for daily sap flow and air temperature, relative humidity, precipitation, wind speed, solar radiation, VPD, VT and ET0 under different soil moisture and groundwater table depth conditions was performed. Diurnal course and hysteresis of sap flow were analyzed as a function of air temperature, solar radiation, VPD and VT on the typical sunny, cloudy and rainy days under different soil moisture conditions. Correlation analysis between daily sap flow and LAI showed that LAI and phenophase significantly influence sap flow and restrict the maximum value of sap flow. The sap flow and its response to environmental factors were compared between Aspen and Epinette. The result could make contributions to improve empirical transpiration modeling for efficient water resource management in the headwater catchment of subhumid region.

  11. Oxygen consumption and heart rate responses to isolated ballet exercise sets.

    PubMed

    Rodrigues-Krause, Josianne; Dos Santos Cunha, Giovani; Alberton, Cristine Lima; Follmer, Bruno; Krause, Mauricio; Reischak-Oliveira, Alvaro

    2014-01-01

    Ballet stage performances are associated with higher cardiorespiratory demand than rehearsals and classes. Hence, new interest is emerging to create periodized training that enhances dancers' fitness while minimizing delayed exercise-induced fatigue and possible injuries. Finding out in what zones of intensity dancers work during different ballet movements may support the use of supplemental training adjusted to the needs of the individual dancer. Therefore, the main purpose of this study was to describe dancers' oxygen consumption (VO2) and heart rate (HR) responses during the performance of nine isolated ballet exercise sets, as correlated with their first and second ventilatory thresholds (VT1 and VT2). Twelve female ballet dancers volunteered for the study. Their maximum oxygen consumption (VO2max), VT1, and VT2 were determined by use of an incremental treadmill test. Nine sets of ballet movements were assessed: pliés, tendus, jetés, rond de jambes, fondus, grand adage (adage), grand battements, temps levés, and sautés. The sets were randomly executed and separated by 5 minute rest periods. ANOVA for repeated measurements followed by the Bonferroni Post-hoc test were applied (p < 0.05). VO2 responses were as follows: pliés (17.6 ± 1.6 ml·kg(-1)·min(-1)); tendus and adage were not significantly greater than VT1; rond de jambes (21.8 ± 3.1 ml·kg(-1) ·min(-1)); fondus and jetés were higher than VT1 and the previous exercises; grand battements (25.8 ± 2.9 ml·kg(-1)·min(-1)) was greater than all the other exercises and VT1; and VT2 was significantly higher than all ballet sets. This stratification followed closely, but not exactly, the variation in HR. For example, rond de jambes (156.8 ± 19 b·min(-1)) did not show any significant difference from all the other ballet sets, nor VT1 or VT2. It is concluded that the workloads of isolated ballet sets, based on VO2 responses, vary between low and moderate aerobic intensity in relation to dancers' VT1 and VT2. However, ballet set workloads may be higher when based on HR responses, due to the intermittent and isometric components of dance.

  12. Characterization of Rabensburg Virus, a Flavivirus Closely Related to West Nile Virus of the Japanese Encephalitis Antigenic Group

    PubMed Central

    Aliota, Matthew T.; Jones, Susan A.; Dupuis, Alan P.; Ciota, Alexander T.; Hubalek, Zdenek; Kramer, Laura D.

    2012-01-01

    Rabensburg virus (RABV), a Flavivirus with ∼76% nucleotide and 90% amino acid identity with representative members of lineage one and two West Nile virus (WNV), previously was isolated from Culex pipiens and Aedes rossicus mosquitoes in the Czech Republic, and phylogenetic and serologic analyses demonstrated that it was likely a new lineage of WNV. However, no direct link between RABV and human disease has been definitively established and the extent to which RABV utilizes the typical WNV transmission cycle is unknown. Herein, we evaluated vector competence and capacity for vertical transmission (VT) in Cx. pipiens; in vitro growth on avian, mammalian, and mosquito cells; and infectivity and viremia production in birds. RABV infection and replication only were detected on mosquito cells. Experimentally inoculated birds did not become infected. Cx. pipiens had poor peroral vector competence and a higher VT rate as compared to US-WNV in Cx. pipiens. As a result, we postulate that RABV is an intermediate between the mosquito-specific and horizontally transmitted flaviviruses. PMID:22724010

  13. Breathing mechanics during exercise with added dead space reflect mechanisms of ventilatory control.

    PubMed

    Wood, Helen E; Mitchell, Gordon S; Babb, Tony G

    2009-09-30

    Small increases in external dead space (V(D)) augment the exercise ventilatory response via a neural mechanism known as short-term modulation (STM). We hypothesized that breathing mechanics would differ during exercise, increased V(D) and STM. Men were studied at rest and during cycle exercise (10-50W) without (Control) and with added V(D) (200-600ml). With added V(D), V(T) increased via increased end-inspiratory lung volume (EILV), with no change in end-expiratory lung volume (EELV), indicating recruitment of inspiratory muscles only. With exercise, V(T) increased via both decreased EELV and increased EILV, indicating recruitment of both expiratory and inspiratory muscles. A significant interaction between the effects of exercise and V(D) on mean inspiratory flow indicated that the augmented exercise ventilatory response with added V(D) (i.e. STM) resulted from increased drive to the inspiratory muscles. These results reveal different patterns of respiratory muscle recruitment among experimental conditions. Hence, we conclude that fundamental differences exist in the neural control of ventilatory responses during exercise, increased V(D) and STM.

  14. Pharmacological Tie2 activation in kidney transplantation.

    PubMed

    Thamm, Kristina; Njau, Florence; Van Slyke, Paul; Dumont, Daniel J; Park, Joon-Keun; Haller, Hermann; David, Sascha

    2016-09-24

    To investigate the therapeutic potential of vasculotide (VT) - a Tie2 activating therapeutic - in kidney transplantation. We performed a murine MHC-mismatched renal transplant model (C57Bl/6 male into Balb/c female) with 60 min cold and 30 min warm ischemia time. 500 ng VT was administered i.p. to donor mice 1 h before organ removal. In addition, recipients received 500 ng VT i.p. directly and 3 d after surgery. Survival was monitored and remaining animals were sacrificed 28 d after transplantation. In this model, we analyzed: (1) organ function; (2) Kaplan-Meier survival; (3) organ damage (periodic acid Schiff staining) via semi-quantitative scoring [0-4 (0 = no injury/inflammation to 4 = very severe injury/inflammation)]; (4) expression of renal endothelial adhesion molecules (ICAM-1) via immunofluorescence (IF) staining, immunoblotting and qPCR; (5) infiltration of inflammatory cells (IF Gr-1, F4/80); and (6) fibrosis via staining of α-smooth muscle actin (αSMA), Sirius red staining and immunoblotting of SMAD3 activation. Exogenous activation of Tie2 with VT resulted in diminished expression of peritubular and glomerular endothelial adhesion molecules. Consequently, infiltration of inflammatory cells (analyzed as ICAM-1, Gr-1 and F4/80 positive cells) was reduced in VT-treated mice compared to controls. Additionally, VT was protective against fibrogenesis after kidney transplantation. Trends towards lower serum creatinine (vehicle: 142 ± 17 μmol/L vs VT: 94 ± 23 μmol/L), urea (vehicle: 76 ± 5 mmol/L vs VT: 60 ± 8 mmol/L) and lactate dehydrogenase (vehicle: 1288 ± 383 iU vs VT: 870 ± 275 iU) were observed on day 6 after transplantation. Kaplan-Meier survival analysis showed improved survival rates in the VT-treated mice that did not reach statistical significance (27% vs 54%, P = 0.24, n = 11 per group). Exogenous activation of Tie2 via VT might reduce infiltration of inflammatory cells into renal tissue thereby protecting the transplant from early graft dysfunction potentially affecting long-term function. Protection of the endothelial microvasculature via the Tie2 axis in the early transplant setting might hold promise as a therapeutic target.

  15. Reasons for recurrent ventricular tachycardia after catheter ablation of post-infarction ventricular tachycardia.

    PubMed

    Yokokawa, Miki; Desjardins, Benoit; Crawford, Thomas; Good, Eric; Morady, Fred; Bogun, Frank

    2013-01-08

    The purpose of this study was to assess the determinants of ventricular tachycardia (VT) recurrence in patients who underwent VT ablation for post-infarction VT. The factors that predict recurrence of VT after catheter ablation in patients with prior infarctions are not well described. Catheter ablation was performed in 98 consecutive patients (88 males [90%]; mean age 67 ± 10 years; ejection fraction 27 ± 13%) with post-infarction VT. Electrograms from the implantable cardioverter-defibrillator were analyzed, and VTs were classified as clinical, nonclinical, or new clinical. A total of 725 VTs were induced during the ablation procedure. All VTs were targeted. In 76 patients, 105 clinical VTs were inducible. Critical sites were identified with entrainment mapping and pace-mapping (≥10 of 12 matching leads) for 75 of 105 clinical VTs (71%) and for 278 of 620 nonclinical VTs (45%). Post-ablation, the clinical VT was not inducible in any patient, and all VTs were rendered noninducible in 63% of the patients. Over a mean follow-up period of 35 ± 23 months, 65 of 98 patients (66%) had no recurrent VTs and 33 (34%) had VT recurrence. A new VT occurred in 26 of 33 patients (79%), and a prior clinical VT recurred in 7 patients (21%). Patients with recurrent VT had a larger scar area as assessed by electroanatomic mapping compared with patients without recurrent VTs (93 ± 40 cm(2) vs. 69 ± 30 cm(2); p = 0.002). In patients with repeat procedures, the majority of inducible VTs for which a critical area could be identified were at a distance of 6 ± 3 mm to the prior ablation lesions. Patients with recurrent VTs have a larger scar as assessed by electroanatomic mapping. Most recurrent VTs were new, and the majority of these VTs were mapped to the vicinity of prior ablation lesions in patients with repeat procedures. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. Highly symmetric D-brane-anti-D-brane effective actions

    NASA Astrophysics Data System (ADS)

    Hatefi, Ehsan

    2017-09-01

    The entire S-matrix elements of four, five and six point functions of D-brane-anti D-brane system are explored. To deal with symmetries of string amplitudes as well as their all order α ' corrections we first address a four point function of one closed string Ramond-Ramond (RR) and two real tachyons on the world volume of brane-anti brane system. We then focus on symmetries of string theory as well as universal tachyon expansion to achieve both string and effective field theory of an RR and three tachyons where the complete algebraic analysis for the whole S-matrix < {V}_{C^{-1}}{V}_{T^{-1}}{V}_{T^0}{V}_{T^0}> was also revealed. Lastly, we employ all the conformal field theory techniques to < {V}_{C^{-1}}{V}_{T^{-1}}{V}_{T^0}{V}_{T^0}{V}_{T^0}> , working out with symmetries of theory and find out the expansion for the amplitude to be able to precisely discover all order singularity structures of D-brane-anti-D-brane effective actions of string theory. Various remarks about the so called generalized Veneziano amplitude and new string couplings are elaborated as well.

  17. The Virtual Teacher (VT) Paradigm: Learning New Patterns of Interpersonal Coordination Using the Human Dynamic Clamp

    PubMed Central

    2015-01-01

    The Virtual Teacher paradigm, a version of the Human Dynamic Clamp (HDC), is introduced into studies of learning patterns of inter-personal coordination. Combining mathematical modeling and experimentation, we investigate how the HDC may be used as a Virtual Teacher (VT) to help humans co-produce and internalize new inter-personal coordination pattern(s). Human learners produced rhythmic finger movements whilst observing a computer-driven avatar, animated by dynamic equations stemming from the well-established Haken-Kelso-Bunz (1985) and Schöner-Kelso (1988) models of coordination. We demonstrate that the VT is successful in shifting the pattern co-produced by the VT-human system toward any value (Experiment 1) and that the VT can help humans learn unstable relative phasing patterns (Experiment 2). Using transfer entropy, we find that information flow from one partner to the other increases when VT-human coordination loses stability. This suggests that variable joint performance may actually facilitate interaction, and in the long run learning. VT appears to be a promising tool for exploring basic learning processes involved in social interaction, unraveling the dynamics of information flow between interacting partners, and providing possible rehabilitation opportunities. PMID:26569608

  18. Ventricular arrhythmias and changes in heart rate preceding ventricular tachycardia in patients with an implantable cardioverter defibrillator.

    PubMed

    Lerma, Claudia; Wessel, Niels; Schirdewan, Alexander; Kurths, Jürgen; Glass, Leon

    2008-07-01

    The objective was to determine the characteristics of heart rate variability and ventricular arrhythmias prior to the onset of ventricular tachycardia (VT) in patients with an implantable cardioverter defibrillator (ICD). Sixty-eight beat-to-beat time series from 13 patients with an ICD were analyzed to quantify heart rate variability and ventricular arrhythmias. The episodes of VT were classified in one of two groups depending on whether the sinus rate in the 1 min preceding the VT was greater or less than 90 beats per minute. In a subset of patients, increased heart rate and reduced heart rate variability was often observed up to 20 min prior to the VT. There was a non-significant trend to higher incidence of premature ventricular complexes (PVCs) before VT compared to control recordings. The patterns of the ventricular arrhythmias were highly heterogeneous among different patients and even within the same patient. Analysis of the changes of heart rate and heart rate variability may have predictive value about the onset of VT in selected patients. The patterns of ventricular arrhythmia could not be used to predict onset of VT in this group of patients.

  19. The Virtual Teacher (VT) Paradigm: Learning New Patterns of Interpersonal Coordination Using the Human Dynamic Clamp.

    PubMed

    Kostrubiec, Viviane; Dumas, Guillaume; Zanone, Pier-Giorgio; Kelso, J A Scott

    2015-01-01

    The Virtual Teacher paradigm, a version of the Human Dynamic Clamp (HDC), is introduced into studies of learning patterns of inter-personal coordination. Combining mathematical modeling and experimentation, we investigate how the HDC may be used as a Virtual Teacher (VT) to help humans co-produce and internalize new inter-personal coordination pattern(s). Human learners produced rhythmic finger movements whilst observing a computer-driven avatar, animated by dynamic equations stemming from the well-established Haken-Kelso-Bunz (1985) and Schöner-Kelso (1988) models of coordination. We demonstrate that the VT is successful in shifting the pattern co-produced by the VT-human system toward any value (Experiment 1) and that the VT can help humans learn unstable relative phasing patterns (Experiment 2). Using transfer entropy, we find that information flow from one partner to the other increases when VT-human coordination loses stability. This suggests that variable joint performance may actually facilitate interaction, and in the long run learning. VT appears to be a promising tool for exploring basic learning processes involved in social interaction, unraveling the dynamics of information flow between interacting partners, and providing possible rehabilitation opportunities.

  20. Rationale, study design and analysis plan of the lung imaging morphology for ventilator settings in acute respiratory distress syndrome study (LIVE study): Study protocol for a randomised controlled trial.

    PubMed

    Jabaudon, Matthieu; Godet, Thomas; Futier, Emmanuel; Bazin, Jean-Étienne; Sapin, Vincent; Roszyk, Laurence; Pereira, Bruno; Constantin, Jean-Michel

    2017-10-01

    Different acute respiratory distress syndrome (ARDS) phenotypes may explain controversial results in clinical trials. Lung-morphology is one of the ARDS-phenotypes and physiological studies suggest different responses in terms of positive-end-expiratory-pressure (PEEP) and recruitment-manoeuvres (RM) according to loss of aeration. To evaluate whether tailored ventilator regimens may impact ARDS outcomes, our group has designed a randomised-clinical-trial of ventilator settings according to lung morphology in moderate-to-severe ARDS (LIVE study). Patients will be enrolled within the first 12hours of ARDS onset. In both groups, volume-controlled ventilation with low tidal-volumes (Vt) will be used to target a plateau pressure≤30 cmH 2 O. In the control group, the PEEP level and inspired fraction of oxygen (FiO 2 ) will be set using the ARDSNet table; a Vt of 6 mL/kg of predicted body weight (PBW) will be set and prone position (PP) will be applied. In the intervention arm, the ventilator will be set according to lung morphology (focal/non-focal) that will be assessed according to CT-scan±chest x-ray+lung echography. For focal ARDS patients, a Vt of 8 mL/kg PBW will be used along with low PEEP and PP. For non-focal ARDS patients, a Vt of 6 mL/kg PBW will be used with RM and PEEP to reach a plateau pressure≤30 cmH 2 O. The primary outcome is all-cause 90-day mortality and the secondary outcomes are: in-hospital mortality, mortality at day 28, 60, 180 and 365; ventilator-free days at day 30, quality of life at one year; ventilator-associated pneumonia rate; barotrauma; ICU and hospital length of stay. This RCT is registered on Clinicaltrials.gov under identifier NCT02149589. Copyright © 2017 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  1. An electrocardiographic scoring system for distinguishing right ventricular outflow tract arrhythmias in patients with arrhythmogenic right ventricular cardiomyopathy from idiopathic ventricular tachycardia.

    PubMed

    Hoffmayer, Kurt S; Bhave, Prashant D; Marcus, Gregory M; James, Cynthia A; Tichnell, Crystal; Chopra, Nagesh; Moxey, Laura; Krahn, Andrew D; Dixit, Sanjay; Stevenson, William; Calkins, Hugh; Badhwar, Nitish; Gerstenfeld, Edward P; Scheinman, Melvin M

    2013-04-01

    Ventricular arrhythmias in patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) and idiopathic ventricular tachycardia (VT) can share a left bundle branch block/inferior axis morphology. We previously reported electrocardiogram characteristics during outflow tract ventricular arrhythmias that helped distinguish VT related to ARVD/C from idiopathic VT. To prospectively validate these criteria. We created a risk score by using a derivation cohort. Two experienced electrophysiologists blinded to the diagnosis prospectively scored patients with VT/premature ventricular contractions (PVCs) with left bundle branch block/inferior axis pattern in a validation cohort of 37 ARVD/C tracings and 49 idiopathic VT tracings. All patients with ARVD/C had their diagnosis confirmed based on the revised task force criteria. Patients with idiopathic VT were selected based on structurally normal hearts with documented right ventricular outflow tract VT successfully treated with ablation. The scoring system provides 3 points for sinus rhythm anterior T-wave inversions in leads V1-V3 and during ventricular arrhythmia: 2 points for QRS duration in lead I≥120 ms, 2 points for QRS notching, and 1 point for precordial transition at lead V5 or later. A score of 5 or greater was able to correctly distinguish ARVD/C from idiopathic VT 93% of the time, with a sensitivity of 84%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 91%. We describe a simple scoring algorithm that uses 12-lead electrocardiogram characteristics to effectively distinguish right ventricular outflow tract arrhythmias originating from patients with ARVD/C versus patients with idiopathic VT. Copyright © 2013 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  2. Pressure-limited sustained inflation vs. gradual tidal inflations for resuscitation in preterm lambs.

    PubMed

    Tingay, David G; Polglase, Graeme R; Bhatia, Risha; Berry, Clare A; Kopotic, Robert J; Kopotic, Clinton P; Song, Yong; Szyld, Edgardo; Jobe, Alan H; Pillow, J Jane

    2015-04-01

    Support of the mechanically complex preterm lung needs to facilitate aeration while avoiding ventilation heterogeneities: whether to achieve this gradually or quickly remains unclear. We compared the effect of gradual vs. constant tidal inflations and a pressure-limited sustained inflation (SI) at birth on gas exchange, lung mechanics, gravity-dependent lung volume distribution, and lung injury in 131-day gestation preterm lambs. Lambs were resuscitated with either 1) a 20-s, 40-cmH2O pressure-limited SI (PressSI), 2) a gradual increase in tidal volume (Vt) over 5-min from 3 ml/kg to 7 ml/kg (IncrVt), or 3) 7 ml/kg Vt from birth. All lambs were subsequently ventilated for 15 min with 7 ml/kg Vt with the same end-expiratory pressure. Lung mechanics, gas exchange and spatial distribution of end-expiratory volume (EEV), and tidal ventilation (electrical impedance tomography) were recorded regularly. At 15 min, early mRNA tissue markers of lung injury were assessed. The IncrVt group resulted in greater tissue hysteresivity at 5 min (P = 0.017; two-way ANOVA), higher alveolar-arterial oxygen difference from 10 min (P < 0.01), and least uniform gravity-dependent distribution of EEV. There were no other differences in lung mechanics between groups, and the PressSI and 7 ml/kg Vt groups behaved similarly throughout. EEV was more uniformly distributed, but Vt least so, in the PressSI group. There were no differences in mRNA markers of lung injury. A gradual increase in Vt from birth resulted in less recruitment of the gravity-dependent lung with worse oxygenation. There was no benefit of a SI at birth over mechanical ventilation with 7 ml/kg Vt. Copyright © 2015 the American Physiological Society.

  3. Out-of-hospital defibrillation with automated external defibrillators: postshock analysis should be delayed.

    PubMed

    Blouin, D; Topping, C; Moore, S; Stiell, I; Afilalo, M

    2001-09-01

    The American Heart Association protocols for use of automated external defibrillators (AEDs) recommend that a rhythm analysis be done immediately after each defibrillation attempt. However, shock is often followed by electrical silence or marginally organized electrical activity before ventricular fibrillation (VF) or ventricular tachycardia (VT) recurs. The optimal timing of postshock analysis for identification of recurrent VF/VT is unknown. This study examines the time to recurrence of VF/VT after a defibrillation attempt with AED. Over an 18-month period, all tapes from patients with out-of-hospital cardiac arrest who received shocks at least once with an AED were screened for recurrent VF/VT. All cases come from a single emergency medical services system providing basic life support, defibrillation with AED, and intubation with an esophageal-tracheal twin-lumen airway device (Combitube) for a population of 633,511 individuals. Pediatric and traumatic cases were excluded. When VF/VT recurred within 3 minutes of the defibrillation attempt, rhythm strips were printed and included in the study. Two cardiology fellows, blinded to the study objectives, measured the time from defibrillation to recurrent VF/VT for each strip. Over the study period, 222 tapes from 96 patients met the inclusion criteria. Only 44 (20%) occurrences of VF/VT had recurred within 6 seconds of defibrillation, 162 (73%) at 60 seconds, and 200 (90%) at 90 seconds. Eighty percent of VF/VT recurred more than 6 seconds after defibrillation and were missed when using current American Heart Association AED protocols. Subsequent analysis should be postponed until at least 30 seconds after defibrillation. Performing 30 seconds of chest compressions after defibrillation before subsequent AED rhythm analysis would increase AED identification of VF/VT to 52%.

  4. A meta-analysis of manual versus remote magnetic navigation for ventricular tachycardia ablation.

    PubMed

    Turagam, Mohit K; Atkins, Donita; Tung, Roderick; Mansour, Moussa; Ruskin, Jeremy; Cheng, Jie; Di Biase, Luigi; Natale, Andrea; Lakkireddy, Dhanunjaya

    2017-09-01

    There are limited studies on the safety and efficacy of remote magnetic navigation (RMN) versus manual navigation (MAN) in ventricular tachycardia (VT) ablation. A comprehensive literature search was performed using the keywords VT ablation, stereotaxis, RMN and MAN in Pubmed, Ebsco, Web of Science, Cochrane, and Google scholar databases. The analysis included seven studies (one randomized, three prospective observational, and three retrospective) including 779 patients [both structural heart disease (SHD) and idiopathic VT] comparing RMN (N = 433) and MAN (N = 339) in VT ablation. The primary end point of long-term VT recurrence was significantly lower with RMN (OR 0.61, 95% CI 0.44-0.85, p = 0.003) compared with MAN. Other end points of acute procedural success (OR 2.13, 95% CI 1.40-3.23, p = 0.0004) was significantly higher with RMN compared with MAN. Fluoroscopy [mean difference -10.42, 95% CI -12.7 to -8.1, p < 0.0001], procedural time [mean difference -9.79, 95% CI -19.27 to -0.3, p = 0.04] and complications (OR 0.35, 95% CI 0.17-0.74, p = 0.0006) were also significantly lower in RMN when compared with MAN. In a subgroup analysis SHD, there was no significant difference in VT recurrence or acute procedural success with RMN vs. MAN. In idiopathic VT, RMN significantly increased acute procedural success with no difference in VT recurrence. The results demonstrate that RMN is safe and effective when compared with MAN in patients with both SHD and idiopathic VT undergoing catheter ablation. Further prospective studies are needed to further verify the safety and efficacy of RMN.

  5. New Substrate-Guided Method of Predicting Slow Conducting Isthmuses of Ventricular Tachycardia: Preliminary Analysis to the Combined Use of Voltage Limit Adjustment and Fast-Fourier Transform Analysis.

    PubMed

    Kuroki, Kenji; Nogami, Akihiko; Igarashi, Miyako; Masuda, Keita; Kowase, Shinya; Kurosaki, Kenji; Komatsu, Yuki; Naruse, Yoshihisa; Machino, Takeshi; Yamasaki, Hiro; Xu, Dongzhu; Murakoshi, Nobuyuki; Sekiguchi, Yukio; Aonuma, Kazutaka

    2018-04-01

    Several conducting channels of ventricular tachycardia (VT) can be identified using voltage limit adjustment (VLA) of substrate mapping. However, the sensitivity or specificity to predict a VT isthmus is not high by using VLA alone. This study aimed to evaluate the efficacy of the combined use of VLA and fast-Fourier transform analysis to predict VT isthmuses. VLA and fast-Fourier transform analyses of local ventricular bipolar electrograms during sinus rhythm were performed in 9 postinfarction patients who underwent catheter ablation for a total of 13 monomorphic VTs. Relatively higher voltage areas on an electroanatomical map were defined as high voltage channels (HVCs), and relatively higher fast-Fourier transform areas were defined as high-frequency channels (HFCs). HVCs were classified into full or partial HVCs (the entire or >30% of HVC can be detectable, respectively). Twelve full HVCs were identified in 7 of 9 patients. HFCs were located on 7 of 12 full HVCs. Five VT isthmuses (71%) were included in the 7 full HVC+/HFC+ sites, whereas no VT isthmus was found in the 5 full HVC+/HFC- sites. HFCs were identical to 9 of 16 partial HVCs. Eight VT isthmuses (89%) were included in the 9 partial HVC+/HFC+ sites, whereas no VT isthmus was found in the 7 partial HVC+/HFC- sites. All HVC+/HFC+ sites predicted VT isthmus with a sensitivity of 100% and a specificity of 80%. Combined use of VLA and fast-Fourier transform analysis may be a useful method to detect VT isthmuses. © 2018 American Heart Association, Inc.

  6. Correlation of proton irradiation induced threshold voltage shifts to deep level traps in AlGaN/GaN heterostructures

    NASA Astrophysics Data System (ADS)

    Zhang, Z.; Cardwell, D.; Sasikumar, A.; Kyle, E. C. H.; Chen, J.; Zhang, E. X.; Fleetwood, D. M.; Schrimpf, R. D.; Speck, J. S.; Arehart, A. R.; Ringel, S. A.

    2016-04-01

    The impact of proton irradiation on the threshold voltage (VT) of AlGaN/GaN heterostructures is systematically investigated to enhance the understanding of a primary component of the degradation of irradiated high electron mobility transistors. The value of VT was found to increase monotonically as a function of 1.8 MeV proton fluence in a sub-linear manner reaching 0.63 V at a fluence of 1 × 1014 cm-2. Silvaco Atlas simulations of VT shifts caused by GaN buffer traps using experimentally measured introduction rates, and energy levels closely match the experimental results. Different buffer designs lead to different VT dependences on proton irradiation, confirming that deep, acceptor-like defects in the GaN buffer are primarily responsible for the observed VT shifts. The proton irradiation induced VT shifts are found to depend on the barrier thickness in a linear fashion; thus, scaling the barrier thickness could be an effective way to reduce such degradation.

  7. Effects of Ving Tsun Chinese Martial Art Training on Upper Extremity Muscle Strength and Eye-Hand Coordination in Community-Dwelling Middle-Aged and Older Adults: A Pilot Study.

    PubMed

    Fong, Shirley S M; Ng, Shamay S M; Cheng, Yoyo T Y; Wong, Janet Y H; Yu, Esther Y T; Chow, Gary C C; Chak, Yvonne T C; Chan, Ivy K Y; Zhang, Joni; Macfarlane, Duncan; Chung, Louisa M Y

    2016-01-01

    Objectives. To evaluate the effects of Ving Tsun (VT) martial art training on the upper extremity muscle strength and eye-hand coordination of middle-aged and older adults. Methods. This study used a nonequivalent pretest-posttest control group design. Forty-two community-dwelling healthy adults participated in the study; 24 (mean age ± SD = 68.5 ± 6.7 years) underwent VT training for 4 weeks (a supervised VT session twice a week, plus daily home practice), and 18 (mean age ± SD = 72.0 ± 6.7 years) received no VT training and acted as controls. Shoulder and elbow isometric muscle strength and eye-hand coordination were evaluated using the Lafayette Manual Muscle Test System and a computerized finger-pointing test, respectively. Results. Elbow extensor peak force increased by 13.9% (P = 0.007) in the VT group and the time to reach peak force decreased (9.9%) differentially in the VT group compared to the control group (P = 0.033). For the eye-hand coordination assessment outcomes, reaction time increased by 2.9% in the VT group and decreased by 5.3% in the control group (P = 0.002). Conclusions. Four weeks of VT training could improve elbow extensor isometric peak force and the time to reach peak force but not eye-hand coordination in community-dwelling middle-aged and older adults.

  8. Prevalences and pregnancy outcome of vanishing twin pregnancies achieved by in vitro fertilization versus natural conception.

    PubMed

    Márton, Virág; Zádori, János; Kozinszky, Zoltan; Keresztúri, Attila

    2016-11-01

    To evaluate whether vanishing twin (VT) pregnancies achieved by in vitro fertilization and intracytoplasmic sperm injection (IVF-ICSI) had a more adverse perinatal outcome than those after natural conception. Longitudinal, retrospective cohort study. Tertiary university hospital. Three hundred and six (78 after IVF-ICSI and 228 after natural conception) VT pregnancies over a 22-year period, with VT cases matched to primarily singleton controls. None. Obstetric and neonatal outcome data. The incidence of VT was statistically significantly higher after natural conception (18.2% of twins) than after IVF-ICSI (12.6% of twins). The odds of VT in pregnancies complicated with pregestational or gestational diabetes were disproportionally higher in IVF-ICSI cases than in spontaneously conceived VT pregnancies (adjusted odds ratio [AOR]: 0.80 vs. 3.10 and 1.00 vs. 1.07, respectively). Previous induced abortion (AOR 1.34) or second-trimester fetal loss (AOR 3.3) increased the risk of VT pregnancies after spontaneous conception. Gestational diabetes mellitus in both the previous (AOR 5.41) and the present (AOR 2.3) pregnancy as well as chronic maternal diseases (AOR 3.5) and placentation anomalies all represented independent risk factors for VT after IVF-ICSI. Vanishing twin pregnancies had a lower prevalence and a worse perinatal outcome after IVF-ICSI as compared with those of their spontaneously conceived counterparts. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  9. An open-label study of sodium oxybate (Xyrem®) in spasmodic dysphonia

    PubMed Central

    Rumbach, Anna F.; Blitzer, Andrew; Frucht, Steven J.; Simonyan, Kristina

    2016-01-01

    Objective Spasmodic dysphonia (SD) is a task-specific laryngeal dystonia that affects speech production. Co-occurring voice tremor (VT) often complicates the diagnosis and clinical management of SD. Treatment of SD and VT is largely limited to botulinum toxin injections into laryngeal musculature; other pharmacological options are not sufficiently developed. Study Design and Methods We conducted an open-label study in 23 SD and 22 SD/VT patients to examine the effects of sodium oxybate (Xyrem®), an oral agent with therapeutic effects similar to those of alcohol in these patients. Blinded randomized analysis of voice and speech samples assessed symptom improvement before and after drug administration. Results Sodium oxybate significantly improved voice symptoms (p = 0.001) primarily by reducing the number of SD-characteristic voice breaks and severity of VT. Sodium oxybate further showed a trend for improving VT symptoms (p = 0.03) in a subset of patients who received successful botulinum toxin injections for the management of their SD symptoms. The drug’s effects were observed approximately 30–40 min after its intake and lasted about 3.5–4 hours. Conclusion Our study demonstrated that sodium oxybate reduced voice symptoms in 82.2% of alcohol-responsive SD patients both with and without co-occurring VT. Our findings suggest that the therapeutic mechanism of sodium oxybate in SD and SD/VT may be linked to that of alcohol and as such sodium oxybate might be beneficial for alcohol-responsive SD and SD/VT patients. PMID:27808415

  10. Effects of Ving Tsun Chinese Martial Art Training on Upper Extremity Muscle Strength and Eye-Hand Coordination in Community-Dwelling Middle-Aged and Older Adults: A Pilot Study

    PubMed Central

    Ng, Shamay S. M.; Cheng, Yoyo T. Y.; Yu, Esther Y. T.; Chow, Gary C. C.; Chak, Yvonne T. C.; Chan, Ivy K. Y.; Zhang, Joni; Macfarlane, Duncan

    2016-01-01

    Objectives. To evaluate the effects of Ving Tsun (VT) martial art training on the upper extremity muscle strength and eye-hand coordination of middle-aged and older adults. Methods. This study used a nonequivalent pretest-posttest control group design. Forty-two community-dwelling healthy adults participated in the study; 24 (mean age ± SD = 68.5 ± 6.7 years) underwent VT training for 4 weeks (a supervised VT session twice a week, plus daily home practice), and 18 (mean age ± SD = 72.0 ± 6.7 years) received no VT training and acted as controls. Shoulder and elbow isometric muscle strength and eye-hand coordination were evaluated using the Lafayette Manual Muscle Test System and a computerized finger-pointing test, respectively. Results. Elbow extensor peak force increased by 13.9% (P = 0.007) in the VT group and the time to reach peak force decreased (9.9%) differentially in the VT group compared to the control group (P = 0.033). For the eye-hand coordination assessment outcomes, reaction time increased by 2.9% in the VT group and decreased by 5.3% in the control group (P = 0.002). Conclusions. Four weeks of VT training could improve elbow extensor isometric peak force and the time to reach peak force but not eye-hand coordination in community-dwelling middle-aged and older adults. PMID:27525020

  11. A Vowel-Based Method for Vocal Tract Control in Clarinet Pedagogy

    ERIC Educational Resources Information Center

    González, Darleny; Payri, Blas

    2017-01-01

    Our review of scientific literature shows that the activity inside the clarinetist's vocal tract (VT) affects pitch and timbre, while also facilitating technical exercises. Clarinetists adapt their VT intuitively and, in some cases, may compensate an inadequate VT configuration through unnecessary pressure, resulting in technical blockage,…

  12. Complete genome analysis of jasmine virus T from Jasminum sambac in China.

    PubMed

    Tang, Yajun; Gao, Fangluan; Yang, Zhen; Wu, Zujian; Yang, Liang

    2016-07-01

    The genome of a potyvirus (isolate JaVT_FZ) recovered from jasmine (Jasminum sambac L.) showing yellow ringspot symptoms in Fuzhou, China, was sequenced. JaVT_FZ is closely related to seven other potyviruses with completely sequenced genomes, with which it shares 66-70 % nucleotide and 52-56 % amino acid sequence identity. However, the coat protein (CP) gene shares 82-92 % nucleotide and 90-97 % amino acid sequence identity with those of two partially sequenced potyviruses, named jasmine potyvirus T (JaVT-jasmine) and jasmine yellow mosaic potyvirus (JaYMV-India), respectively. This suggests that JaVT_FZ, JaVT-jasmine and JaYMV-India should be regarded as members of a single potyvirus species, for which the name "Jasmine virus T" has priority.

  13. Xtalk: a path-based approach for identifying crosstalk between signaling pathways

    PubMed Central

    Tegge, Allison N.; Sharp, Nicholas; Murali, T. M.

    2016-01-01

    Motivation: Cells communicate with their environment via signal transduction pathways. On occasion, the activation of one pathway can produce an effect downstream of another pathway, a phenomenon known as crosstalk. Existing computational methods to discover such pathway pairs rely on simple overlap statistics. Results: We present Xtalk, a path-based approach for identifying pairs of pathways that may crosstalk. Xtalk computes the statistical significance of the average length of multiple short paths that connect receptors in one pathway to the transcription factors in another. By design, Xtalk reports the precise interactions and mechanisms that support the identified crosstalk. We applied Xtalk to signaling pathways in the KEGG and NCI-PID databases. We manually curated a gold standard set of 132 crosstalking pathway pairs and a set of 140 pairs that did not crosstalk, for which Xtalk achieved an area under the receiver operator characteristic curve of 0.65, a 12% improvement over the closest competing approach. The area under the receiver operator characteristic curve varied with the pathway, suggesting that crosstalk should be evaluated on a pathway-by-pathway level. We also analyzed an extended set of 658 pathway pairs in KEGG and to a set of more than 7000 pathway pairs in NCI-PID. For the top-ranking pairs, we found substantial support in the literature (81% for KEGG and 78% for NCI-PID). We provide examples of networks computed by Xtalk that accurately recovered known mechanisms of crosstalk. Availability and implementation: The XTALK software is available at http://bioinformatics.cs.vt.edu/~murali/software. Crosstalk networks are available at http://graphspace.org/graphs?tags=2015-bioinformatics-xtalk. Contact: ategge@vt.edu, murali@cs.vt.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:26400040

  14. Experimental study of three-dimensional fin-channel charge trapping flash memories with titanium nitride and polycrystalline silicon gates

    NASA Astrophysics Data System (ADS)

    Liu, Yongxun; Matsukawa, Takashi; Endo, Kazuhiko; O'uchi, Shinichi; Tsukada, Junichi; Yamauchi, Hiromi; Ishikawa, Yuki; Mizubayashi, Wataru; Morita, Yukinori; Migita, Shinji; Ota, Hiroyuki; Masahara, Meishoku

    2014-01-01

    Three-dimensional (3D) fin-channel charge trapping (CT) flash memories with different gate materials of physical-vapor-deposited (PVD) titanium nitride (TiN) and n+-polycrystalline silicon (poly-Si) have successfully been fabricated by using (100)-oriented silicon-on-insulator (SOI) wafers and orientation-dependent wet etching. Electrical characteristics of the fabricated flash memories including statistical threshold voltage (Vt) variability, endurance, and data retention have been comparatively investigated. It was experimentally found that a larger memory window and a deeper erase are obtained in PVD-TiN-gated metal-oxide-nitride-oxide-silicon (MONOS)-type flash memories than in poly-Si-gated poly-Si-oxide-nitride-oxide-silicon (SONOS)-type memories. The larger memory window and deeper erase of MONOS-type flash memories are contributed by the higher work function of the PVD-TiN metal gate than of the n+-poly-Si gate, which is effective for suppressing electron back tunneling during erase operation. It was also found that the initial Vt roll-off due to the short-channel effect (SCE) is directly related to the memory window roll-off when the gate length (Lg) is scaled down to 46 nm or less.

  15. The influence of quarantine on reproductive cycling in wild-caught Baboons (Papio anubis).

    PubMed

    Liechty, Emma R; Wang, Diane Y; Chen, Emily; Chai, Daniel; Bell, Jason D; Bergin, Ingrid L

    2015-12-01

    Stress impacts nonhuman primate menstrual cycle length but the impact of quarantine is unknown. A retrospective analysis was performed on cycle data from 31 wild-caught baboons during and following quarantine. Cycling initiated in 94 days (19-181) and length normalized within 4-6 cycles. Quarantine significantly impacts menstrual cycle length. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. The effects of locomotor-respiratory coupling on the pattern of breathing in horses.

    PubMed Central

    Lafortuna, C L; Reinach, E; Saibene, F

    1996-01-01

    1. To investigate the effect of locomotor activity on the pattern of breathing in quadrupeds, ventilatory response was studied in four healthy horses during horizontal and inclined (7%) treadmill exercise at different velocities (1.4-6.9 m s(-1)) and during chemical stimulation with a rebreathing method. Stride frequency (f(s)) and locomotor-respiratory coupling (LRC) were also simultaneously determined by means of video recordings synchronized with respiratory events. 2. Tidal volume (V(T)) was positively correlated with pulmonary ventilation (V(E)) but significantly different linear regression equations were found between the experimental conditions (P < 0.0001), since the chemical hyperventilation was mainly due to increases in V(T), whereas the major contribution to exercise hyperpnoea came from changes in respiratory frequency (f(R)). 3. The average f(R) at each exercise level was not significantly different from f(S), although there was not always a tight 1:1 LRC. At constant speeds, f(S) was independent of the treadmill slope and hence the greater V(E) during inclined exercise was due to increased V(T). 4. At any ventilatory level, the differences in breathing patterns between locomotion and rebreathing or locomotion at different slopes derived from different set points of the inspiratory off-switch mechanism. 5. The percentage of single breaths entrained with locomotor rhythm rose progressively and significantly with treadmill speed (P < 0.0001) up to a 1:1 LRC and was significantly affected by treadmill slope (P < 0.001). 6. A LRC of 1:1 was systematically observed at canter (10 out of 10 trials) and sometimes at trot (5 out of 14) and it entailed (i) a 4- to 5-fold reduction in both V(T) and f(R) variability, and (ii) a gait-specific phase locking of inspiratory onset during the locomotor cycle. 7. It is concluded that different patterns of breathing are employed during locomotion and rebreathing due to the interference between locomotor and respiratory functions, which may play a role in the optimization and control of exercise ventilation in horses. PMID:9019552

  17. Contemporary ventilator management in patients with and at risk of ALI/ARDS.

    PubMed

    Chang, Steven Y; Dabbagh, Ousama; Gajic, Ognen; Patrawalla, Amee; Elie, Marie-Carmelle; Talmor, Daniel S; Malhotra, Atul; Adesanya, Adebola; Anderson, Harry L; Blum, James M; Park, Pauline K; Gong, Michelle Ng

    2013-04-01

    Ventilator practices in patients at risk for acute lung injury (ALI) and ARDS are unclear. We examined factors associated with choice of set tidal volumes (VT), and whether VT < 8 mL/kg predicted body weight (PBW) relates to the development of ALI/ARDS. We performed a secondary analysis of a multicenter cohort of adult subjects at risk of lung injury with and without ALI/ARDS at onset of invasive ventilation. Descriptive statistics were used to describe ventilator practices in specific settings and ALI/ARDS risk groups. Logistic regression analysis was used to determine the factors associated with the use of VT < 8 mL/kg PBW and the relationship of VT to ALI/ARDS development and outcome. Of 829 mechanically ventilated patients, 107 met the criteria for ALI/ARDS at time of intubation, and 161 developed ALI/ARDS after intubation (post-intubation ALI/ARDS). There was significant intercenter variability in initial ventilator settings, and in the incidence of ALI/ARDS and post-intubation ALI/ARDS. The median VT was 7.96 (IQR 7.14-8.94) mL/kg PBW in ALI/ARDS subjects, and 8.45 (IQR 7.50-9.55) mL/kg PBW in subjects without ALI/ARDS (P = .004). VT decreased from 8.40 (IQR 7.38-9.37) mL/kg PBW to 7.97 (IQR 6.90-9.23) mL/kg PBW (P < .001) in those developing post-intubation ALI/ARDS. Among subjects without ALI/ARDS, VT ≥ 8 mL/kg PBW was associated with shorter height and higher body mass index, while subjects with pneumonia were less likely to get ≥ 8 mL/kg PBW. Initial VT ≥ 8 mL/kg PBW was not associated with the post-intubation ALI/ARDS (adjusted odds ratio 1.30, 95% CI 0.74-2.29) or worse outcomes. Post-intubation ALI/ARDS subjects had mortality similar to subjects intubated with ALI/ARDS. Clinicians seem to respond to ALI/ARDS with lower initial VT. Initial VT, however, was not associated with the development of post-intubation ALI/ARDS or other outcomes.

  18. Effects of tidal volume and methacholine on low-frequency total respiratory impedance in dogs.

    PubMed

    Lutchen, K R; Jackson, A C

    1990-05-01

    The frequency dependence of respiratory impedance (Zrs) from 0.125 to 4 Hz (Hantos et al., J. Appl. Physiol. 60: 123-132, 1986) may reflect inhomogeneous parallel time constants or the inherent viscoelastic properties of the respiratory tissues. However, studies on the lung alone or chest wall alone indicate that their impedance features are also dependent on the tidal volumes (VT) of the forced oscillations. The goals of this study were 1) to identify how total Zrs at lower frequencies measured with random noise (RN) compared with that measure with larger VT, 2) to identify how Zrs measured with RN is affected by bronchoconstriction, and 3) to identify the impact of using linear models for analyzing such data. We measured Zrs in six healthy dogs by use of a RN technique from 0.125 to 4 Hz or with a ventilator from 0.125 to 0.75 Hz with VT from 50 to 250 ml. Then methacholine was administered and the RN was repeated. Two linear models were fit to each separate set of data. Both models assume uniform airways leading to viscoelastic tissues. For healthy dogs, the respiratory resistance (Rrs) decreased with frequency, with most of the decrease occurring from 0.125 to 0.375 Hz. Significant VT dependence of Rrs was seen only at these lower frequencies, with Rrs higher as VT decreased. The respiratory compliance (Crs) was dependent on VT in a similar fashion at all frequencies, with Crs decreasing as VT decreased. Both linear models fit the data well at all VT, but the viscoelastic parameters of each model were very sensitive to VT. After methacholine, the minimum Rrs increased as did the total drop with frequency. Nevertheless the same models fit the data well, and both the airways and tissue parameters were altered after methacholine. We conclude that inferences based only on low-frequency Zrs data are problematic because of the effects of VT on such data (and subsequent linear modeling of it) and the apparent inability of such data to differentiate parallel inhomogeneities from normal viscoelastic properties of the respiratory tissues.

  19. Improving trend in ventricular fibrillation/pulseless ventricular tachycardia out-of-hospital cardiac arrest in Rochester, Minnesota: A 26-year observational study from 1991 to 2016.

    PubMed

    Okubo, Masashi; Atkinson, Elizabeth J; Hess, Erik P; White, Roger D

    2017-11-01

    Mortality from out-of-hospital cardiac arrest (OHCA) is characterized by substantial regional variation. The Institute of Medicine (IOM) recently recommended enhancing the capabilities of EMS systems to improve outcome. In this study, we analyzed the trend in outcome from ventricular fibrillation/pulseless ventricular tachycardia (VF/pVT) OHCA in Rochester, MN. Survival from these forms of arrest is commonly employed as a benchmark of Emergency Medical Services (EMS) system performance. Using a population-based Utstein-style registry in Rochester, MN where a first responder early defibrillation system is utilized, we evaluated outcome from all EMS-treated VF/pVT arrests and the subgroup of bystander-witnessed VF/pVT from 1991 to 2016. Outcome measurement was neurologically intact survival to discharge, defined as Cerebral Performance Category (CPC) 1 or 2. We divided the 26-year study into three periods: 1991-1997, 1998-2008, and 2009-2016, based on initiation of the first responder system of police officers in 1991 and fire-rescue personnel in 1998, and the latter period for comparison with our previous report in 2009. We observed 355 all VF/pVT arrests and 292 bystander-witnessed VF/pVT arrests between 1991 and 2016. In 2009-2016, neurologically intact survival to discharge from overall VF/pVT and bystander-witnessed VF/pVT increased to 53.7% and 65.2%, respectively, compared with 39.5% and 43.4% in 1991-1997. Using multivariable analysis, survival significantly increased in 2009-2016 among all VF/pVT arrests (adjusted OR, 3.10; 95% CI, 1.54-6.40) and bystander-witnessed VF/pVT (adjusted OR, 4.28; 95% CI, 2.01-9.50), compared with those in 1991-1997. We observed a significant improving secular trend in neurologically intact survival from VF/pVT cardiac arrests with a relatively high recent survival rate in this EMS System. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Effect of PEEP and Tidal Volume on Ventilation Distribution and End-Expiratory Lung Volume: A Prospective Experimental Animal and Pilot Clinical Study

    PubMed Central

    Becher, Tobias; Schädler, Dirk; Pulletz, Sven; Freitag-Wolf, Sandra; Weiler, Norbert; Frerichs, Inéz

    2013-01-01

    Introduction Lung-protective ventilation aims at using low tidal volumes (VT) at optimum positive end-expiratory pressures (PEEP). Optimum PEEP should recruit atelectatic lung regions and avoid tidal recruitment and end-inspiratory overinflation. We examined the effect of VT and PEEP on ventilation distribution, regional respiratory system compliance (CRS), and end-expiratory lung volume (EELV) in an animal model of acute lung injury (ALI) and patients with ARDS by using electrical impedance tomography (EIT) with the aim to assess tidal recruitment and overinflation. Methods EIT examinations were performed in 10 anaesthetized pigs with normal lungs ventilated at 5 and 10 ml/kg body weight VT and 5 cmH2O PEEP. After ALI induction, 10 ml/kg VT and 10 cmH2O PEEP were applied. Afterwards, PEEP was set according to the pressure-volume curve. Animals were randomized to either low or high VT ventilation changed after 30 minutes in a crossover design. Ventilation distribution, regional CRS and changes in EELV were analyzed. The same measures were determined in five ARDS patients examined during low and high VT ventilation (6 and 10 (8) ml/kg) at three PEEP levels. Results In healthy animals, high compared to low VT increased CRS and ventilation in dependent lung regions implying tidal recruitment. ALI reduced CRS and EELV in all regions without changing ventilation distribution. Pressure-volume curve-derived PEEP of 21±4 cmH2O (mean±SD) resulted in comparable increase in CRS in dependent and decrease in non-dependent regions at both VT. This implied that tidal recruitment was avoided but end-inspiratory overinflation was present irrespective of VT. In patients, regional CRS differences between low and high VT revealed high degree of tidal recruitment and low overinflation at 3±1 cmH2O PEEP. Tidal recruitment decreased at 10±1 cmH2O and was further reduced at 15±2 cmH2O PEEP. Conclusions Tidal recruitment and end-inspiratory overinflation can be assessed by EIT-based analysis of regional CRS. PMID:23991138

  1. Civilian casualties of terror-related explosions: The impact of vascular trauma on treatment and prognosis.

    PubMed

    Heldenberg, Eitan; Givon, Adi; Simon, Daniel; Bass, Arie; Almogy, Gidon; Peleg, Kobi

    2016-09-01

    A high prevalence (10%) of vascular trauma (VT) was previously described in terror-related trauma as compared with non-terror-related trauma (1%), in a civilian setting. No data regarding outcome of VT casualties of improvised explosive device (IED) explosions, in civilian settings, are available. The aim of the current study is to present the prognosis of civilian casualties of IED explosions with and without VT. A retrospective analysis of the Israeli National Trauma Registry was performed. All patients in the registry from September 2000 to December 2005 who were victims of explosions were included. These patients were subdivided into patients with VT (n = 109) and non-VT (NVT) (n = 1,152). Both groups were analyzed according to mechanism of trauma, type and severity of injury, and treatment. Of 1,261 explosion casualties, there were 109 VT victims (8.6%). Patients with VT tended to be more complex, with a higher injury severity score (ISS): 17.4% with ISS 16 to 24 as compared with only 10.5%. In the group of critically injured patients (ISS, 25-75), 51.4% had VT compared with only 15.5% of the NVT patients. As such, a heavy share of hospitals' resources were used-trauma bay admission (62.4%), operating rooms (91.7%), and intensive care unit beds (55.1%). The percentage of VT patients who were admitted for more than 15 days was 2.3 times higher than that observed among the NVT patients. Lower-extremity VT injuries were the most prevalent. Although many resources are being invested in treating this group of patients, their mortality rate is approximately five times more than NVT (22.9% vs. 4.9%). Vascular trauma casualties of IED explosions are more complex and have poorer prognosis. Their higher ISS markedly increases the hospital's resource utilization, and as such, it should be taken into consideration either upon the primary evacuation from the scene or when secondary modulation is needed in order to reduce the burden of the hospitals receiving the casualties. Prognostic/epidemiologic study, level V.

  2. A bench evaluation of fraction of oxygen in air delivery and tidal volume accuracy in home care ventilators available for hospital use

    PubMed Central

    Baboi, Loredana; Subtil, Fabien

    2016-01-01

    Background Turbine-powered ventilators are not only designed for long-term ventilation at home but also for hospital use. It is important to verify their capabilities in delivering fraction of oxygen in air (FIO2) and tidal volume (VT). Methods We assessed the FIO2 accuracy and the VT delivery in four home care ventilators (HCV) on the bench. The four HCV were Astral 150, Elisée 150, Monnal T50 and Trilogy 200 HCV, which were connected to a lung model (ASL 5000). For assessing FIO2 accuracy, lung model was set to mimic an obstructive lung and HCV were set in volume controlled mode (VC). They supplied with air, 3 or 15 L/min oxygen and FIO2 was measured by using a ventilator tester (Citrex H4TM). For the VT accuracy, the lung model was set in a way to mimic three adult configurations (normal, obstructive, or restrictive respiratory disorder) and one pediatric configuration. Each HCV was set in VC. Two VT (300 and 500 mL) in adult lung configuration and one 50 mL VT in pediatric lung configuration, at two positive end expiratory pressures 5 and 10 cmH2O, were tested. VT accuracy was measured as volume error (the relative difference between set and measured VT). Statistical analysis was performed by suing one-factor ANOVA with a Bonferroni correction for multiple tests. Results For Astral 150, Elisée 150, Monnal T50 and Trilogy 200, FIO2 averaged 99.2%, 93.7%, 86.3%, and 62.1%, respectively, at 15 L/min oxygen supplementation rate (P<0.001). Volume error was 0.5%±0%, −38%±0%, −9%±0%, −29%±0% and −36%±0% for pediatric lung condition (P<0.001). In adult lung configurations, Monnal T50 systematically over delivered VT and Trilogy 150 was sensitive to lung configuration when VT was set to 300 mL at either positive end-expiratory pressure (PEEP). Conclusions HCV are different in terms of FIO2 efficiency and VT delivery. PMID:28149559

  3. Digital Logic and Reconfigurable Interconnects Using Aluminum Gallium Arsenide Electro-Optic Fredkin Gates

    DTIC Science & Technology

    1994-06-01

    length and coupling coefficient for the zero-gap directional coupler are obtained by using Eq. 3.2.39. Bums and Milton Effective Index Method In a 1975...nj) with •i wavegulde thicness b. Effective index N1 is then used to find the effective >Vt.,:, ;- 105 c a ¶ 2 n. n_ z n2 - : n4 Three-Dimensional...constant for the TM, modes is determined in a manner similar to the one used for the TEp modes. First, effective index N1 of 2-D Waveguide I is found by

  4. Validating Lung Models Using the ASL 5000 Breathing Simulator.

    PubMed

    Dexter, Amanda; McNinch, Neil; Kaznoch, Destiny; Volsko, Teresa A

    2018-04-01

    This study sought to validate pediatric models with normal and altered pulmonary mechanics. PubMed and CINAHL databases were searched for studies directly measuring pulmonary mechanics of healthy infants and children, infants with severe bronchopulmonary dysplasia and neuromuscular disease. The ASL 5000 was used to construct models using tidal volume (VT), inspiratory time (TI), respiratory rate, resistance, compliance, and esophageal pressure gleaned from literature. Data were collected for a 1-minute period and repeated three times for each model. t tests compared modeled data with data abstracted from the literature. Repeated measures analyses evaluated model performance over multiple iterations. Statistical significance was established at a P value of less than 0.05. Maximum differences of means (experimental iteration mean - clinical standard mean) for TI and VT are the following: term infant without lung disease (TI = 0.09 s, VT = 0.29 mL), severe bronchopulmonary dysplasia (TI = 0.08 s, VT = 0.17 mL), child without lung disease (TI = 0.10 s, VT = 0.17 mL), and child with neuromuscular disease (TI = 0.09 s, VT = 0.57 mL). One-sample testing demonstrated statistically significant differences between clinical controls and VT and TI values produced by the ASL 5000 for each iteration and model (P < 0.01). The greatest magnitude of differences was negligible (VT < 1.6%, TI = 18%) and not clinically relevant. Inconsistencies occurred with the models constructed on the ASL 5000. It was deemed accurate for the study purposes. It is therefore essential to test models and evaluate magnitude of differences before use.

  5. An open-label study of sodium oxybate in Spasmodic dysphonia.

    PubMed

    Rumbach, Anna F; Blitzer, Andrew; Frucht, Steven J; Simonyan, Kristina

    2017-06-01

    Spasmodic dysphonia (SD) is a task-specific laryngeal dystonia that affects speech production. Co-occurring voice tremor (VT) often complicates the diagnosis and clinical management of SD. Treatment of SD and VT is largely limited to botulinum toxin injections into laryngeal musculature; other pharmacological options are not sufficiently developed. Open-label study. We conducted an open-label study in 23 SD and 22 SD/VT patients to examine the effects of sodium oxybate (Xyrem), an oral agent with therapeutic effects similar to those of alcohol in these patients. Blinded randomized analysis of voice and speech samples assessed symptom improvement before and after drug administration. Sodium oxybate significantly improved voice symptoms (P = .001) primarily by reducing the number of SD-characteristic voice breaks and severity of VT. Sodium oxybate further showed a trend for improving VT symptoms (P = .03) in a subset of patients who received successful botulinum toxin injections for the management of their SD symptoms. The drug's effects were observed approximately 30 to 40 minutes after its intake and lasted about 3.5 to 4 hours. Our study demonstrated that sodium oxybate reduced voice symptoms in 82.2% of alcohol-responsive SD patients both with and without co-occurring VT. Our findings suggest that the therapeutic mechanism of sodium oxybate in SD and SD/VT may be linked to that of alcohol, and as such, sodium oxybate might be beneficial for alcohol-responsive SD and SD/VT patients. 4 Laryngoscope, 127:1402-1407, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  6. Effect of Sandostatin LAR on sleep apnoea in acromegaly: correlation with computerized tomographic cephalometry and hormonal activity.

    PubMed

    Ip, M S; Tan, K C; Peh, W C; Lam, K S

    2001-10-01

    Sleep apnoea has been reported to occur in subjects with acromegaly. This study evaluates the relationship among biochemical activity, sleep apnoeic activity and upper airway anatomic profile in acromegaly, and the effect of Sandostatin LAR, a long-acting somatostatin analogue, on these parameters. Fourteen subjects with acromegaly were recruited. Subjects were assessed at baseline and those with apnoea-hypopnoea index (AHI) > or = 5 were reassessed after 6 months of treatment with Sandostatin LAR 20-30 mg IMI 4-weekly. Biochemical activity was assessed with levels of GH and IGF-1. Sleep disordered breathing was assessed with overnight polysomnography. Upper airway anatomic profile was defined with computerized tomographic cephalometry. Of 14 subjects (age 42.0 +/- 8.1 years, mean +/- SD; 11 men) at baseline, there was a positive correlation between GH and tongue length (VT; P = 0.004), and between AHI and cephalometric indices: length of soft palate (PMU; P = 0.002); mandibular plane-hyoid bone distance (MPH; P = 0.017), maximum thickness of soft palate (Max-SP; P = 0.018) and VT (P = 0.027). Eight patients had sleep disordered breathing (AHI > or = 5) which was predominantly obstructive in nature (AHI = 29.4 +/- 22.6). After treatment, there were significant improvements in hormonal profile: GH, mU/l (before, 51.5 +/- 27.8; after, 8.0 +/- 7.4; P = 0.017) and IGF-1, nmol/l (before, 95.5 +/- 23.4; after, 35.0 +/- 12.4; P = 0.012); sleep-disordered breathing: AHI (before, 29.4 +/- 22.6; after, 13.4 +/- 11.12; P = 0.025), snoring episodes (before, 486 +/- 240; after, 165 +/- 170; P = 0.05); cephalometric indices, mm: MPH (before, 18.8 +/- 12.1; after, 14.8 +/- 8.4; P = 0.018), VT (before, 72.3 +/- 4.4; after, 69.7 +/- 4.3; P = 0.05). There was a positive correlation between the reduction in GH and AHI (r = 0.738, P = 0.037). The findings demonstrated that there was correlation between sleep apnoea severity and soft tissue overgrowth at the upper airway region in acromegaly. They also suggest that Sandostatin LAR improved obstructive sleep apnoea in acromegaly, and the effect might be partly mediated via a reduction in upper airway soft tissue, in particular that of the tongue, concomitant with a reduction in GH levels.

  7. Potential role for IL-5 and IL-6 in enhanced IgA secretion by Peyer's patch cells isolated from mice acutely exposed to vomitoxin.

    PubMed

    Yan, D; Zhou, H R; Brooks, K H; Pestka, J J

    1997-09-26

    Dietary exposure to vomitoxin (VT) results in hyperelevated serum IgA and IgA nephropathy in mice. To assess the possible role of cytokines in this IgA dysregulation, the effects of a single oral exposure in B6C3F1 male mice to 0, 5 or 25 mg/kg BW VT on production of IgA and cytokines in Peyer's patch (PP) and spleen cell cultures were evaluated. IgA levels were increased significantly in PP cell cultures prepared from mice at 2 or 24 h after oral exposure to VT and subsequently stimulated with phorbol myristate acetate (PMA) and ionomycin (ION) or with lipopolysaccharide (LPS). Significant effects on IgA production were not observed in spleen cell cultures. Since cytokines such as IL-2, IL-4, IL-5 and IL-6 have been shown to promote IgA production, the effect of the same VT exposure regimen on secretion of these mediators was determined in PP and spleen cultures. Supernatant IL-2 and IL-4 levels were unaffected by the prior treatment of animals with VT. In contrast, IL-5 levels were increased significantly in 7-day PP cell cultures obtained 2 h after VT exposure both with and without PMA + ION exposure but not in other cultures. IL-6 levels were increased significantly in LPS-treated cultures prepared from PP at 2 and 24 h following exposure to VT. IL-6 levels were also elevated significantly in both PMA + ION or LPS treated cultures from spleen isolated at 2 h but not 24 h post VT exposure. To determine whether IL-5 or IL-6 play a role in IgA hyperelevation in vitro, PP and spleen cells from mice obtained 2 h after exposure to 25 mg/kg VT were cultured in the presence of neutralizing cytokine antibodies (Abs) and IgA production was monitored. Consistent with IL-5's previously documented role in IgA production, anti-IL-5 decreased IgA levels to background in cultures of both control and VT-exposed PP or spleen cells in the presence of either PMA + ION or LPS. Similar results were seen with addition of anti-IL-6. IgA levels were decreased to a lesser extent in PP cells cultured with LPS and in spleen cells cultured with PMA + ION from VT-exposed mice to which anti-IL-2 Ab was added. Thus, the potential for enhanced IgA production exists in lymphocytes as early as 2 h and as late as 24 h after a single oral exposure to VT and this may be related to the increased capacity to secrete helper cytokines of T cell and macrophage origin. Taken together, the results suggest that the superinduction of cytokine expression may, in part, be responsible for upregulation of IgA secretion in mice exposed orally to VT.

  8. Safety of varenicline tartrate and counseling versus counseling alone for smoking cessation: a randomized controlled trial for inpatients (STOP study).

    PubMed

    Carson, Kristin Veronica; Smith, Brian James; Brinn, Malcolm Philip; Peters, Matthew J; Fitridge, Robert; Koblar, Simon A; Jannes, Jim; Singh, Kuljit; Veale, Antony J; Goldsworthy, Sharon; Litt, John; Edwards, David; Hnin, Khin Moe; Esterman, Adrian Jeffrey

    2014-11-01

    Inpatient medical settings offer an opportunistic environment for initiating smoking cessation interventions to patients reflecting on their health. Current evidence has shown the superior efficacy of varenicline tartrate (VT) for smoking cessation compared with other tobacco cessation therapies; however, recent evidence also has highlighted concerns about the safety and tolerability of VT. Given these apprehensions, we aimed to evaluate the safety and effectiveness of VT plus quitline-counseling compared to quitline-counseling alone in the inpatient medical setting. Adult patients (n = 392, 20-75 years) admitted with a smoking-related illnesses to 3 hospitals were randomized to receive either 12 weeks of varenicline tartrate (titrated from 0.5mg daily to 1mg twice daily) plus quitline-counseling (VT+C), (n = 196) or quitline-counseling alone (n = 196). VT was well tolerated in the inpatient setting among subjects admitted with acute smoking-related illnesses (mean age 52.8±2.89 and 53.7±2.77 years in the VT+C and counseling alone groups, respectively). The most common self-reported adverse event during the 12-week treatment phase was nausea (16.3% in the VT+C group compared with 1.5% in the counseling alone group). Thirteen deaths occurred during the study period (n = 6 were in the VT+C arm compared with n = 7 in the counseling alone arm). All of these subjects had known comorbidities or developed underlying comorbidities. VT appears to be a safe and well-tolerated opportunistic treatment for inpatient smokers who have related chronic disease. Based on the proven efficacy of varenicline from outpatient studies and our recent inpatient evidence, we suggest it be considered as part of standard care in the hospital setting. © The Author 2014. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  9. The effect of helium on ventilator performance: study of five ventilators and a bedside Pitot tube spirometer.

    PubMed

    Oppenheim-Eden, A; Cohen, Y; Weissman, C; Pizov, R

    2001-08-01

    To assess in vitro the performance of five mechanical ventilators-Siemens 300 and 900C (Siemens-Elma; Solna, Sweden), Puritan Bennett 7200 (Nellcor Puritan Bennett; Pleasanton, CA), Evita 4 (Dragerwerk; Lubeck, Germany), and Bear 1000 (Bear Medical Systems; Riverside CA)-and a bedside sidestream spirometer (Datex CS3 Respiratory Module; Datex-Ohmeda; Helsinki, Finland) during ventilation with helium-oxygen mixtures. In vitro study. ICUs of two university-affiliated hospitals. Each ventilator was connected to 100% helium through compressed air inlets and then tested at three to six different tidal volume (VT) settings using various helium-oxygen concentrations (fraction of inspired oxygen [FIO(2)] of 0.2 to 1.0). FIO(2) and VT were measured with the Datex CS3 spirometer, and VT was validated with a water-displacement spirometer. The Puritan Bennett 7200 ventilator did not function with helium. With the other four ventilators, delivered FIO(2) was lower than the set FIO(2). For the Siemens 300 and 900C ventilators, this difference could be explained by the lack of 21% oxygen when helium was connected to the air supply port, while for the other two ventilators, a nonlinear relation was found. The VT of the Siemens 300 ventilator was independent of helium concentration, while for the other three ventilators, delivered VT was greater than the set VT and was dependent on helium concentration. During ventilation with 80% helium and 20% oxygen, VT increased to 125% of set VT for the Siemens 900C ventilator, and more than doubled for the Evita 4 and Bear 1000 ventilators. Under the same conditions, the Datex CS3 spirometer underestimated the delivered VT by about 33%. At present, no mechanical ventilator is calibrated for use with helium. This investigation offers correction factors for four ventilators for ventilation with helium.

  10. Evaluation of the Variable Reluctance Transducer/Carrier Amplifier Method of Measuring Low Pneumatic Pressures in Aerodynamic and Propulsion Testing.

    DTIC Science & Technology

    1983-02-01

    in ZT position, adjust Rx and VT to give the following conditions simul taneously: a) Vc to be specifiied value * RMS Volts. b) VRX Vz. 3. Record: RX...conditions simultaneously: a) V to be specified value as before.c b) VRX Vc. 2. Record: Rx = Q_ ; VT = ; VR =Vc (Volts). C. CALCULATE VOLTAGE AND...2 _V2 cos 8 = cos (180-,) = VRX V2 . VT 2VRX* V Z =R (cos + isino) = Rz + JWTLZ (OHMS) VT x10 (MILLIAMPERES) E(Rx+Rz)2 + LZ2 󈧏 2 • =TLz COIL "Q

  11. Temporal Variation of the Rotation of the Solar Mean Magnetic Field

    NASA Astrophysics Data System (ADS)

    Xie, J. L.; Shi, X. J.; Xu, J. C.

    2017-04-01

    Based on continuous wavelet transformation analysis, the daily solar mean magnetic field (SMMF) from 1975 May 16 to 2014 July 31 is analyzed to reveal its rotational behavior. Both the recurrent plot in Bartels form and the continuous wavelet transformation analysis show the existence of rotational modulation in the variation of the daily SMMF. The dependence of the rotational cycle lengths on solar cycle phase is also studied, which indicates that the yearly mean rotational cycle lengths generally seem to be longer during the rising phase of solar cycles and shorter during the declining phase. The mean rotational cycle length for the rising phase of all of the solar cycles in the considered time is 28.28 ± 0.67 days, while for the declining phase it is 27.32 ± 0.64 days. The difference of the mean rotational cycle lengths between the rising phase and the declining phase is 0.96 days. The periodicity analysis, through the use of an auto-correlation function, indicates that the rotational cycle lengths have a significant period of about 10.1 years. Furthermore, the cross-correlation analysis indicates that there exists a phase difference between the rotational cycle lengths and solar activity.

  12. Accounting for length-bias and selection effects in estimating the distribution of menstrual cycle length

    PubMed Central

    Lum, Kirsten J.; Sundaram, Rajeshwari; Louis, Thomas A.

    2015-01-01

    Prospective pregnancy studies are a valuable source of longitudinal data on menstrual cycle length. However, care is needed when making inferences of such renewal processes. For example, accounting for the sampling plan is necessary for unbiased estimation of the menstrual cycle length distribution for the study population. If couples can enroll when they learn of the study as opposed to waiting for the start of a new menstrual cycle, then due to length-bias, the enrollment cycle will be stochastically larger than the general run of cycles, a typical property of prevalent cohort studies. Furthermore, the probability of enrollment can depend on the length of time since a woman’s last menstrual period (a backward recurrence time), resulting in selection effects. We focus on accounting for length-bias and selection effects in the likelihood for enrollment menstrual cycle length, using a recursive two-stage approach wherein we first estimate the probability of enrollment as a function of the backward recurrence time and then use it in a likelihood with sampling weights that account for length-bias and selection effects. To broaden the applicability of our methods, we augment our model to incorporate a couple-specific random effect and time-independent covariate. A simulation study quantifies performance for two scenarios of enrollment probability when proper account is taken of sampling plan features. In addition, we estimate the probability of enrollment and the distribution of menstrual cycle length for the study population of the Longitudinal Investigation of Fertility and the Environment Study. PMID:25027273

  13. 77 FR 75837 - Amendment of Time of Designation for Restricted Area R-6501B; Underhill, VT

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-26

    ... R-6501B; Underhill, VT AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule. SUMMARY: This action amends the time of designation for restricted area R-6501B, Underhill, VT by adding a... INFORMATION: Background The current time of designation of restricted area R-6501B reads [[Page 75838...

  14. 33 CFR 110.8 - Lake Champlain, N.Y. and Vt.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Lake Champlain, N.Y. and Vt. 110... ANCHORAGES ANCHORAGE REGULATIONS Special Anchorage Areas § 110.8 Lake Champlain, N.Y. and Vt. (a) Ticonderoga, N.Y. An area shoreward of a line bearing 312° from Ticonderoga Light to the southeast corner of the...

  15. Volcano-tectonic earthquakes: A new tool for estimating intrusive volumes and forecasting eruptions

    NASA Astrophysics Data System (ADS)

    White, Randall; McCausland, Wendy

    2016-01-01

    We present data on 136 high-frequency earthquakes and swarms, termed volcano-tectonic (VT) seismicity, which preceded 111 eruptions at 83 volcanoes, plus data on VT swarms that preceded intrusions at 21 other volcanoes. We find that VT seismicity is usually the earliest reported seismic precursor for eruptions at volcanoes that have been dormant for decades or more, and precedes eruptions of all magma types from basaltic to rhyolitic and all explosivities from VEI 0 to ultraplinian VEI 6 at such previously long-dormant volcanoes. Because large eruptions occur most commonly during resumption of activity at long-dormant volcanoes, VT seismicity is an important precursor for the Earth's most dangerous eruptions. VT seismicity precedes all explosive eruptions of VEI ≥ 5 and most if not all VEI 4 eruptions in our data set. Surprisingly we find that the VT seismicity originates at distal locations on tectonic fault structures at distances of one or two to tens of kilometers laterally from the site of the eventual eruption, and rarely if ever starts beneath the eruption site itself. The distal VT swarms generally occur at depths almost equal to the horizontal distance of the swarm from the summit out to about 15 km distance, beyond which hypocenter depths level out. We summarize several important characteristics of this distal VT seismicity including: swarm-like nature, onset days to years prior to the beginning of magmatic eruptions, peaking of activity at the time of the initial eruption whether phreatic or magmatic, and large non-double couple component to focal mechanisms. Most importantly we show that the intruded magma volume can be simply estimated from the cumulative seismic moment of the VT seismicity from: Log10 V = 0.77 Log ΣMoment - 5.32, with volume, V, in cubic meters and seismic moment in Newton meters. Because the cumulative seismic moment can be approximated from the size of just the few largest events, and is quite insensitive to precise locations, the intruded magma volume can be quickly and easily estimated with few short-period seismic stations. Notable cases in which distal VT events preceded eruptions at long-dormant volcanoes include: Nevado del Ruiz (1984-1985), Pinatubo (1991), Unzen (1989-1995), Soufriere Hills (1995), Shishaldin (1989-1999), Tacana' (1985-1986), Pacaya (1980-1984), Rabaul (1994), and Cotopaxi (2001). Additional cases are recognized at frequently active volcanoes including Popocateptl (2001-2003) and Mauna Loa (1984). We present four case studies (Pinatubo, Soufriere Hills, Unzen, and Tacana') in which we demonstrate the above mentioned VT characteristics prior to eruptions. Using regional data recorded by NEIC, we recognized in near-real time that a huge distal VT swarm was occurring, deduced that a proportionately huge magmatic intrusion was taking place beneath the long dormant Sulu Range, New Britain Island, Papua New Guinea, that it was likely to lead to eruptive activity, and warned Rabaul Volcano Observatory days before a phreatic eruption occurred. This confirms the value of this technique for eruption forecasting. We also present a counter-example where we deduced that a VT swarm at Volcan Cosiguina, Nicaragua, indicated a small intrusion, insufficient to reach the surface and erupt. Finally, we discuss limitations of the method and propose a mechanism by which this distal VT seismicity is triggered by magmatic intrusion.

  16. Performance and technological feasibility of rocket powered HTHL-SSTO with take-off assist (aerospace plane/ekranoplane)

    NASA Astrophysics Data System (ADS)

    Tomita, Nobuyuki; Nebylov, Alexander V.; Sokolov, Victor V.; Ohkami, Yoshiaki

    It might be said that it is common understanding that rocket-powered single stage to orbit (SSTO) aerospace planes will become feasible with near-term technology as described in [1] (Koelle, D. E. Survey and comparison of winged launch vehicle options, ISTS 94-g-11 V 1994) and [2] (Bekey, I. Why SSTO rocket launch vehicles are now feasible and practical, IAF-94-V.1.524 1994). Among two methods of launching aerospace planes into orbit, vertical take-off (VT) and horizontal take-off (HT), it seems that VT takes the lead from HT [1, 2]. The decision for the X-33 program by NASA, also, seems to favor VT. In retrospect, almost all of the launch vehicles in the past have been VT, mainly because VT solved the problem of exit from atmosphere to space. However, broadening the range of requirements for space transportation systems from military to commercial and unmanned to manned seems to favor the need for HT. In this paper, the authors are going to prove that aerospace plane/ekranoplane system, which is a reusable launch vehicle system based on the HT concept, with ekranoplane as a take-off and possibly, landing assist, could be competitive with the VT concept from both technological and economical view points. Ekranoplane is a wing-in-ground-effect craft (WIG), which moves at a speed of approximately 0.5 M, carrying heavy loads above the sea surface. Combination of high initial velocity and high performance tri-propellant engine for aerospace plane makes it possible to configure an aerospace plane which is competitive with VT. Other specific features of HT in comparison with VT are discussed.

  17. Effect of leak and breathing pattern on the accuracy of tidal volume estimation by commercial home ventilators: a bench study.

    PubMed

    Luján, Manel; Sogo, Ana; Pomares, Xavier; Monsó, Eduard; Sales, Bernat; Blanch, Lluís

    2013-05-01

    New home ventilators are able to provide clinicians data of interest through built-in software. Monitoring of tidal volume (VT) is a key point in the assessment of the efficacy of home mechanical ventilation. To assess the reliability of the VT provided by 5 ventilators in a bench test. Five commercial ventilators from 4 different manufacturers were tested in pressure support mode with the help of a breathing simulator under different conditions of mechanical respiratory pattern, inflation pressure, and intentional leakage. Values provided by the built-in software of each ventilator were compared breath to breath with the VT monitored through an external pneumotachograph. Ten breaths for each condition were compared for every tested situation. All tested ventilators underestimated VT (ranges of -21.7 mL to -83.5 mL, which corresponded to -3.6% to -14.7% of the externally measured VT). A direct relationship between leak and underestimation was found in 4 ventilators, with higher underestimations of the VT when the leakage increased, ranging between -2.27% and -5.42% for each 10 L/min increase in the leakage. A ventilator that included an algorithm that computes the pressure loss through the tube as a function of the flow exiting the ventilator had the minimal effect of leaks on the estimation of VT (0.3%). In 3 ventilators the underestimation was also influenced by mechanical pattern (lower underestimation with restrictive, and higher with obstructive). The inclusion of algorithms that calculate the pressure loss as a function of the flow exiting the ventilator in commercial models may increase the reliability of VT estimation.

  18. Protective versus Conventional Ventilation for Surgery: A Systematic Review and Individual Patient Data Meta-analysis.

    PubMed

    Serpa Neto, Ary; Hemmes, Sabrine N T; Barbas, Carmen S V; Beiderlinden, Martin; Biehl, Michelle; Binnekade, Jan M; Canet, Jaume; Fernandez-Bustamante, Ana; Futier, Emmanuel; Gajic, Ognjen; Hedenstierna, Göran; Hollmann, Markus W; Jaber, Samir; Kozian, Alf; Licker, Marc; Lin, Wen-Qian; Maslow, Andrew D; Memtsoudis, Stavros G; Reis Miranda, Dinis; Moine, Pierre; Ng, Thomas; Paparella, Domenico; Putensen, Christian; Ranieri, Marco; Scavonetto, Federica; Schilling, Thomas; Schmid, Werner; Selmo, Gabriele; Severgnini, Paolo; Sprung, Juraj; Sundar, Sugantha; Talmor, Daniel; Treschan, Tanja; Unzueta, Carmen; Weingarten, Toby N; Wolthuis, Esther K; Wrigge, Hermann; Gama de Abreu, Marcelo; Pelosi, Paolo; Schultz, Marcus J

    2015-07-01

    Recent studies show that intraoperative mechanical ventilation using low tidal volumes (VT) can prevent postoperative pulmonary complications (PPCs). The aim of this individual patient data meta-analysis is to evaluate the individual associations between VT size and positive end-expiratory pressure (PEEP) level and occurrence of PPC. Randomized controlled trials comparing protective ventilation (low VT with or without high levels of PEEP) and conventional ventilation (high VT with low PEEP) in patients undergoing general surgery. The primary outcome was development of PPC. Predefined prognostic factors were tested using multivariate logistic regression. Fifteen randomized controlled trials were included (2,127 patients). There were 97 cases of PPC in 1,118 patients (8.7%) assigned to protective ventilation and 148 cases in 1,009 patients (14.7%) assigned to conventional ventilation (adjusted relative risk, 0.64; 95% CI, 0.46 to 0.88; P < 0.01). There were 85 cases of PPC in 957 patients (8.9%) assigned to ventilation with low VT and high PEEP levels and 63 cases in 525 patients (12%) assigned to ventilation with low VT and low PEEP levels (adjusted relative risk, 0.93; 95% CI, 0.64 to 1.37; P = 0.72). A dose-response relationship was found between the appearance of PPC and VT size (R2 = 0.39) but not between the appearance of PPC and PEEP level (R2 = 0.08). These data support the beneficial effects of ventilation with use of low VT in patients undergoing surgery. Further trials are necessary to define the role of intraoperative higher PEEP to prevent PPC during nonopen abdominal surgery.

  19. Influence of gestational age on dead space and alveolar ventilation in preterm infants ventilated with volume guarantee.

    PubMed

    Neumann, Roland P; Pillow, Jane J; Thamrin, Cindy; Larcombe, Alexander N; Hall, Graham L; Schulzke, Sven M

    2015-01-01

    Ventilated preterm infant lungs are vulnerable to overdistension and underinflation. The optimal ventilator-delivered tidal volume (VT) in these infants is unknown and may depend on the extent of alveolarisation at birth. We aimed to calculate respiratory dead space (VD) from the molar mass (MM) signal of an ultrasonic flowmeter (VD,MM) in very preterm infants on volume-targeted ventilation (VT target, 4-5 ml/kg) and to study the association between gestational age (GA) and VD,MM-to-VT ratio (VD,MM/VT), alveolar tidal volume (VA) and alveolar minute volume (AMV). This was a single-centre, prospective, observational, cohort study in a neonatal intensive care unit. Tidal breathing analysis was performed in ventilated very preterm infants (GA range 23-32 weeks) on day 1 of life. Valid measurements were obtained in 43/51 (87%) infants. Tidal breathing variables were analysed using multivariable linear regression. VD,MM/VT was negatively associated with GA after adjusting for birth weight Z score (p < 0.001, R(2) = 0.26). This association was primarily influenced by the appliance dead space. Despite similar VT/kg and VA/kg across all studied infants, respiratory rate and AMV/kg increased with GA. VD,app rather than anatomical VD is the major factor influencing increased VD,MM/VT at a younger GA. A volume guarantee setting of 4-5 ml/kg in the Dräger Babylog® 8000 plus ventilator may be inappropriate as a universal target across the GA range of 23-32 weeks. Differences between measured and set VT and the dependence of this difference on GA require further investigation. © 2014 S. Karger AG, Basel.

  20. Electrocardiographic characteristics of left ventricular outflow tract tachycardia.

    PubMed

    Hachiya, H; Aonuma, K; Yamauchi, Y; Harada, T; Igawa, M; Nogami, A; Iesaka, Y; Hiroe, M; Marumo, F

    2000-11-01

    Catheter ablation of idiopathic left ventricular outflow tract tachycardia (LVOT-VT) is rare because a safe ablation technique at this site has not been described, and serious complications may occur. This study compared the QRS morphology of LVOT-VT with that of idiopathic right ventricular outflow tract tachycardia. A comparison was made between the electrocardiographic characteristics of LVOT-VT originating from the supravalvular region of a coronary cusp (Supra-Ao group) with those of LVOT-VT originating from the infravalvular endocardial region of a coronary cusp of the aortic valve within the LV (Infra-Ao group). After precise mapping of the right ventricle, left ventricle, pulmonary artery, coronary cusps, and proximal portion of the anterior interventricular vein, there were 17 patients in whom VT was thought to be located at the LVOT by both activation and pace mapping. They were divided between a Supra-Ao group (n = 8), and an Infra-Ao group (n = 9). Analysis of the 12-lead electrocardiogram (ECG) revealed an S wave in lead I in all 17 patients. A precordial R wave transition was also observed at V1 or V2 in 16 patients (94%). In 7 of 8 patients (88%) with Supra-Ao LVOT-VT, no S wave was observed in either V5 or V6. In contrast, an Rs pattern was observed in both V5 and V6, or in V6 only, in 100% of the patients with Infra-Ao LVOT-VT. A LVOT-VT should be suspected when the ECG shows an S wave in lead I and an R/S ratio greater than 1 in lead V1 or V2, versus a coronary cusp location if there is no S wave in either lead V5 or V6.

  1. Adaptive support ventilation may deliver unwanted respiratory rate-tidal volume combinations in patients with acute lung injury ventilated according to an open lung concept.

    PubMed

    Dongelmans, Dave A; Paulus, Frederique; Veelo, Denise P; Binnekade, Jan M; Vroom, Margreeth B; Schultz, Marcus J

    2011-05-01

    With adaptive support ventilation, respiratory rate and tidal volume (V(T)) are a function of the Otis least work of breathing formula. We hypothesized that adaptive support ventilation in an open lung ventilator strategy would deliver higher V(T)s to patients with acute lung injury. Patients with acute lung injury were ventilated according to a local guideline advising the use of lower V(T) (6-8 ml/kg predicted body weight), high concentrations of positive end-expiratory pressure, and recruitment maneuvers. Ventilation parameters were recorded when the ventilator was switched to adaptive support ventilation, and after recruitment maneuvers. If V(T) increased more than 8 ml/kg predicted body weight, airway pressure was limited to correct for the rise of V(T). Ten patients with a mean (±SD) Pao(2)/Fio(2) of 171 ± 86 mmHg were included. After a switch from pressure-controlled ventilation to adaptive support ventilation, respiratory rate declined (from 31 ± 5 to 21 ± 6 breaths/min; difference = 10 breaths/min, 95% CI 3-17 breaths/min, P = 0.008) and V(T) increased (from 6.5 ± 0.8 to 9.0 ± 1.6 ml/kg predicted body weight; difference = 2.5 ml, 95% CI 0.4-4.6 ml/kg predicted body weight, P = 0.02). Pressure limitation corrected for the rise of V(T), but minute ventilation declined, forcing the user to switch back to pressure-controlled ventilation. Adaptive support ventilation, compared with pressure-controlled ventilation in an open lung strategy setting, delivers a lower respiratory rate-higher V(T) combination. Pressure limitation does correct for the rise of V(T), but leads to a decline in minute ventilation.

  2. Effect of Air Pollution on Menstrual Cycle Length-A Prognostic Factor of Women's Reproductive Health.

    PubMed

    Merklinger-Gruchala, Anna; Jasienska, Grazyna; Kapiszewska, Maria

    2017-07-20

    Air pollution can influence women's reproductive health, specifically menstrual cycle characteristics, oocyte quality, and risk of miscarriage. The aim of the study was to assess whether air pollution can affect the length of the overall menstrual cycle and the length of its phases (follicular and luteal). Municipal ecological monitoring data was used to assess the air pollution exposure during the monitored menstrual cycle of each of 133 woman of reproductive age. Principal component analyses were used to group pollutants (PM 10 , SO₂, CO, and NO x ) to represent a source-related mixture. PM 10 and SO₂ assessed separately negatively affected the length of the luteal phase after standardization (b = -0.02; p = 0.03; b = -0.06; p = 0.02, respectively). Representing a fossil fuel combustion emission, they were also associated with luteal phase shortening (b = -0.32; p = 0.02). These pollutants did not affect the follicular phase length and overall cycle length, neither in single- nor in multi-pollutant models. CO and NO x assessed either separately or together as a traffic emission were not associated with overall cycle length or the length of cycle phases. Luteal phase shortening, a possible manifestation of luteal phase deficiency, can result from fossil fuel combustion. This suggests that air pollution may contribute to fertility problems in women.

  3. New findings on venous thrombogenesis

    PubMed Central

    Byrnes, James R.; Wolberg, Alisa S.

    2017-01-01

    Summary Venous thrombosis (VT) is the third most common cause of cardiovascular death worldwide. Complications from VT and pulmonary embolism are the leading cause of lost disability-adjusted life years. Risks include genetic (e.g., non-O blood group, activated protein C resistance, hyperprothrombinemia) and acquired (e.g., age, surgery, cancer, pregnancy, immobilisation, female hormone use) factors. Pathophysiologic mechanisms that promote VT are incompletely understood, but involve abnormalities in blood coagulability, vessel function, and flow (so-called Virchow’s Triad). Epidemiologic studies of humans, animal models, and biochemical and biophysical investigations have revealed contributions from extrinsic, intrinsic, and common pathways of coagulation, endothelial cells, leukocytes, red blood cells, platelets, cell-derived microvesicles, stasis-induced changes in vascular cells, and blood rheology. Knowledge of these mechanisms may yield new therapeutic targets. Characterisation of mechanisms that mediate VT formation and stability, particularly in aging, are needed to advance understanding of VT. PMID:27878206

  4. Idiopathic ventricular tachycardia and fibrillation.

    PubMed

    Belhassen, B; Viskin, S

    1993-06-01

    Important data have recently been added to our understanding of sustained ventricular tachyarrhythmias occurring in the absence of demonstrable heart disease. Idiopathic ventricular tachycardia (VT) is usually of monomorphic configuration and can be classified according to its site of origin as either right monomorphic (70% of all idiopathic VTs) or left monomorphic VT. Several physiopathological types of monomorphic VT can be presently individualized, according to their mode of presentation, their relationship to adrenergic stress, or their response to various drugs. The long-term prognosis is usually good. Idiopathic polymorphic VT is a much rarer type of arrhythmia with a less favorable prognosis. Idiopathic ventricular fibrillation may represent an underestimated cause of sudden cardiac death in ostensibly healty patients. A high incidence of inducibility of sustained polymorphic VT with programmed ventricular stimulation has been found by our group, but not by others. Long-term prognosis on Class IA antiarrhythmic medications that are highly effective at electrophysiologic study appears excellent.

  5. Trends and Issues in Vocational Training in the Republic of China on Taiwan.

    ERIC Educational Resources Information Center

    Lee, Lung-Sheng

    Vocational training (VT) in Taiwan is categorized into public training (PT) and enterprise training (ET). PT is provided primarily by 13 PT centers, and ET is provided in various ways. A review of the state of VT in Taiwan established that VT policies and practices are being influenced by increasing emphasis on the knowledge-based economy and…

  6. Vasculotide reduces endothelial permeability and tumor cell extravasation in the absence of binding to or agonistic activation of Tie2

    PubMed Central

    Wu, Florence TH; Lee, Christina R; Bogdanovic, Elena; Prodeus, Aaron; Gariépy, Jean; Kerbel, Robert S

    2015-01-01

    Angiopoietin-1 (Ang1) activation of Tie2 receptors on endothelial cells (ECs) reduces adhesion by tumor cells (TCs) and limits junctional permeability to TC diapedesis. We hypothesized that systemic therapy with Vasculotide (VT)—a purported Ang1 mimetic, Tie2 agonist—can reduce the extravasation of potentially metastatic circulating TCs by similarly stabilizing the host vasculature. In vitro, VT and Ang1 treatments impeded endothelial hypermeability and the transendothelial migration of MDA-MB-231•LM2-4 (breast), HT29 (colon), or SN12 (renal) cancer cells to varying degrees. In mice, VT treatment inhibited the transit of TCs through the pulmonary endothelium, but not the hepatic or lymphatic endothelium. In the in vivo LM2-4 model, VT monotherapy had no effect on primary tumors, but significantly delayed distant metastatic dissemination to the lungs. In the post-surgical adjuvant treatment setting, VT therapeutically complemented sunitinib therapy, an anti-angiogenic tyrosine kinase inhibitor which limited the local growth of residual disease. Unexpectedly, detailed investigations into the putative mechanism of action of VT revealed no evidence of Tie2 agonism or Tie2 binding; alternative mechanisms have yet to be determined. PMID:25851538

  7. Accounting for length-bias and selection effects in estimating the distribution of menstrual cycle length.

    PubMed

    Lum, Kirsten J; Sundaram, Rajeshwari; Louis, Thomas A

    2015-01-01

    Prospective pregnancy studies are a valuable source of longitudinal data on menstrual cycle length. However, care is needed when making inferences of such renewal processes. For example, accounting for the sampling plan is necessary for unbiased estimation of the menstrual cycle length distribution for the study population. If couples can enroll when they learn of the study as opposed to waiting for the start of a new menstrual cycle, then due to length-bias, the enrollment cycle will be stochastically larger than the general run of cycles, a typical property of prevalent cohort studies. Furthermore, the probability of enrollment can depend on the length of time since a woman's last menstrual period (a backward recurrence time), resulting in selection effects. We focus on accounting for length-bias and selection effects in the likelihood for enrollment menstrual cycle length, using a recursive two-stage approach wherein we first estimate the probability of enrollment as a function of the backward recurrence time and then use it in a likelihood with sampling weights that account for length-bias and selection effects. To broaden the applicability of our methods, we augment our model to incorporate a couple-specific random effect and time-independent covariate. A simulation study quantifies performance for two scenarios of enrollment probability when proper account is taken of sampling plan features. In addition, we estimate the probability of enrollment and the distribution of menstrual cycle length for the study population of the Longitudinal Investigation of Fertility and the Environment Study. Published by Oxford University Press 2014. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  8. A Special Ingredient (VtR) Containing Oligostilbenes Isolated from Vitis thunbergii Prevents Bone Loss in Ovariectomized Mice: In Vitro and In Vivo Study

    PubMed Central

    Huang, Yu-Ling; Liu, Yen-Wenn; Huang, Yu-Jou; Chiou, Wen-Fei

    2013-01-01

    Vitis thunbergii is used in Taiwan as a botanical supplement for inflammatory bone diseases. This study aims to examine its direct effect on bone metabolism. Three-month-old female mice were randomly divided into ovariectomized control (OVX), sham operated (SHAM), and ovariectomy treated with either 17β-estradiol or a special ingredient (VtR) fractionated from an ethanol extract of V. thunbergii started two weeks after ovariectomy. VtR treatment for 8 weeks significantly ameliorated the deterioration of bone mineral density and reversed all the ovariectomy-induced changes in  μ-CT parameters. The antiosteoporotic effect of VtR accompanied decrease in serum levels of C-terminal telopeptides of type I collagen (CTx), interleukin-7, and ration of RANKL/osteoprotegerin (OPG) but rise in osteocalcin concentration. Sparse calcified microarchitecture and less alkaline-phosphatase- (ALP-) positive cells were observed at the femur and vertebral sites in OVX mice while VtR remarkably restored such variation. HPLC analysis showed (+)-vitisin-A, (−)-vitisin-B, and ampelopsin C predominated in VtR. Both (−)-vitisin B and ampelopsin C increased ALP activity and bone nodule formation in cultured osteoblasts. Instead of stimulating osteoblastogenesis, (+)-vitisin A dramatically repressed osteoclasts differentiation and bone resorption. The results suggested VtR composed of diverse components to reciprocally drive osteoblastogenesis and interdict osteoclastogenesis may serve as a potential botanic drug for osteoporosis therapy. PMID:23662133

  9. Trace metals in fugitive dust from unsurfaced roads in the Viburnum Trend resource mining District of Missouri--implementation of a direct-suspension sampling methodology.

    PubMed

    Witt, Emitt C; Wronkiewicz, David J; Pavlowsky, Robert T; Shi, Honglan

    2013-09-01

    Fugitive dust from 18 unsurfaced roadways in Missouri were sampled using a novel cyclonic fugitive dust collector that was designed to obtain suspended bulk samples for analysis. The samples were analyzed for trace metals, Fe and Al, particle sizes, and mineralogy to characterize the similarities and differences between roadways. Thirteen roads were located in the Viburnum Trend (VT) mining district, where there has been a history of contaminant metal loading of local soils; while the remaining five roads were located southwest of the VT district in a similar rural setting, but without any mining or industrial process that might contribute to trace metal enrichment. Comparison of these two groups shows that trace metal concentration is higher for dusts collected in the VT district. Lead is the dominant trace metal found in VT district dusts representing on average 79% of the total trace metal concentration, and was found moderately to strongly enriched relative to unsurfaced roads in the non-VT area. Fugitive road dust concentrations calculated for the VT area substantially exceed the 2008 Federal ambient air standard of 0.15μgm(-3) for Pb. The pattern of trace metal contamination in fugitive dust from VT district roads is similar to trace metal concentrations patterns observed for soils measured more than 40years ago indicating that Pb contamination in the region is persistent as a long-term soil contaminant. Published by Elsevier Ltd.

  10. Incidence of upper limb venous thrombosis associated with peripherally inserted central catheters (PICC).

    PubMed

    Abdullah, B J J; Mohammad, N; Sangkar, J V; Abd Aziz, Y F; Gan, G G; Goh, K Y; Benedict, I

    2005-07-01

    The objective of this study was to prospectively determine the incidence of venous thrombosis (VT) in the upper limbs in patients with peripherally inserted central catheters (PICC). We prospectively investigated the incidence of VT in the upper limbs of 26 patients who had PICC inserted. The inclusion criteria were all patients who had a PICC inserted, whilst the exclusion criterion was the inability to perform a venogram (allergies, previous contrast medium reaction and inability of gaining venous access). Both valved and non-valved catheters were evaluated. Prior to removal of the PICC, an upper limb venogram was performed. The number of segments involved with VT were determined. The duration of central venous catheterization was classified as; less than 6 days, between 6 days and 14 days and more than 14 days. VT was confirmed in 38.5% (10/26) of the patients. The majority 85.7% (12/14) were complete occlusive thrombi and the majority of VT only involved one segment. There was no statistical correlation between the site of insertion of the PICC and the location of VT. Neither was there any observed correlation between the occurrence of VT with the patient's history of hypertension, hypercholesterolaemia, coronary artery disease, diabetes mellitus, cardiac insufficiency, smoking or cancer. There was also no statistical correlation with the size of the catheter. In conclusion, PICCs are associated with a significant risk of upper extremity deep vein thrombosis (UEVT).

  11. Volcano-Tectonic Activity at Deception Island Volcano Following a Seismic Swarm in the Bransfield Rift (2014-2015)

    NASA Astrophysics Data System (ADS)

    Almendros, J.; Carmona, E.; Jiménez, V.; Díaz-Moreno, A.; Lorenzo, F.

    2018-05-01

    In September 2014 there was a sharp increase in the seismic activity of the Bransfield Strait, Antarctica. More than 9,000 earthquakes with magnitudes up to 4.6 located SE of Livingston Island were detected over a period of 8 months. A few months after the series onset, local seismicity at the nearby (˜35 km) Deception Island volcano increased, displaying enhanced long-period seismicity and several outbursts of volcano-tectonic (VT) earthquakes. Before February 2015, VT earthquakes occurred mainly at 5-20 km SW of Deception Island. In mid-February the numbers and sizes of VT earthquakes escalated, and their locations encompassed the whole volcanic edifice, suggesting a situation of generalized unrest. The activity continued in anomalously high levels at least until May 2015. Given the spatial and temporal coincidence, it is unlikely that the Livingston series and the Deception VT swarm were unrelated. We propose that the Livingston series may have produced a triggering effect on Deception Island volcano. Dynamic stresses associated to the seismic swarm may have induced overpressure in the unstable volcanic system, leading to a magmatic intrusion that may in turn have triggered the VT swarm. Alternatively, both the Livingston earthquakes and the VT swarm could be consequences of a magmatic intrusion at Deception Island. The Livingston series would be an example of precursory distal VT swarm, which seems to be a common feature preceding volcanic eruptions and magma intrusions in long-dormant volcanoes.

  12. Patterning of physiological and affective responses in older active adults during a maximal graded exercise test and self-selected exercise.

    PubMed

    Smith, Ashleigh E; Eston, Roger; Tempest, Gavin D; Norton, Belinda; Parfitt, Gaynor

    2015-09-01

    The American College of Sports Medicine has highlighted the importance of considering the physiological and affective responses to exercise when setting exercise intensity. Here, we examined the relationship between exercise intensity and physiological and affective responses in active older adults. Eighteen participants (60-74 years; 64.4 ± 3.9; 8 women) completed a maximal graded exercise test (GXT) on a treadmill. Since time to exhaustion in the GXT differed between participants, heart rate (HR), oxygen consumption (VO2), affective valence (affect) and rating of perceived exertion (RPE) were expressed relative to the individually determined ventilatory threshold (%atVT). During the GXT, VO2, HR and RPE increased linearly (all P < 0.01). Affect declined initially (but remained positive) (P = 0.03), stabilised around VT (still positive) (P > 0.05) and became negative towards the end of the test (P < 0.01). In a subsequent session, participants completed a 20-min bout of self-selected exercise (at a preferred intensity). Initially, participants chose to exercise below VT (88.2 ± 17.4 %VO2atVT); however, the intensity was adjusted to work at, or above VT (107.7 ± 19.9 %VO2atVT) after 10 min (P < 0.001), whilst affect remained positive. Together, these findings indicate that exercise around VT, whether administered during an exercise test, or self-selected by the participant, is likely to result in positive affective responses in older adults.

  13. EOS-AM1 Nickel Hydrogen Cell

    NASA Technical Reports Server (NTRS)

    Bennett, Charles W.; Keys, Denney J.; Rao, Gopalakrishna M.; Wannemacher, Hari E.; Vaidyanathan, Harry

    1997-01-01

    This paper reports the interim results of the Earth Observing System AM-1 project (EOS-AM-1) nickel hydrogen cell life test being conducted under contract to National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) at the Lockheed Martin Missile and Space (LMMS) facility in East Windsor, NJ; and at COMSAT Labs., Clarksburg, MD. The purpose of die tests is to verify that the EOS-AM-1 cell design can meet five years of real-time Low Earth Orbit (LEO) cycling. The tests include both real-time LEO and accelerated stress tests. At LMMS, the first real-time LEO simulated 99 minute orbital cycle started on February 7, 1994 and the test has been running continuously since that time, with 18,202 LEO cycles completed as of September 1, 1997. Each cycle consists of a 64 minute charge (VT at 1.507 volts per cell, 1.06 C/D ratio, followed by 0.6 ampere trickle charge) and a 35 minute constant power discharge at 177 watts (22.5% DOD). At COMSAT, the accelerated stress test consists of 90 minute orbital cycles at 60% DOD with a 30 minute discharge at 60 amperes and a 60 minute charge at 40 amperes (VT at 1.54 volts per cell to 1.09 C/D ratio, followed by 0.6 ampere trickle charge). The real-time LEO life test battery consists of seven, 50AH (nameplate rating) Eagle-Picher, Inc. (EPI) Mantech cells manufactured into three, 3-cell pack assemblies (there are two place holder cells that are not part of the life test electrical circuit). The test pack is configured to simulate the conductive thermal design of the spacecraft battery, including: conductive aluminum sleeves, 3-cell pack aluminum baseplate, and honeycomb panel all mounted to a liquid (-5 C) cold plate. The entire assembly is located in a thermal chamber operating at +30 C. The accelerated stress test unit consists of five cells mounted in machined aluminum test sleeves and is operating at +10 C. The real-time LEO life test battery has met all performance requirements through the first 18,202 cycles, including: end of charge mid discharge cell voltages and voltage gradients; end of charge and discharge cell pressures; within cell and between cell temperature gradients; discharge capacity; current and power levels; and all charge parameters. The accelerated stress test battery has completed 11,998 cycles when the test was terminated. The stress test unit met all test parameters. This paper reports battery perfortnances as a funcfion of cycle life for both the real-time LEO and the accelerated life test regimes.

  14. EOS--AM1 Nickel Hydrogen Cell Interim Life Test Report

    NASA Technical Reports Server (NTRS)

    Bennett, C. W.; Keys, D. J.; Rao, G. M.; Wannemacher, H. E.; Vaidyanathan H.

    1999-01-01

    This paper reports the interim results of the Earth Observing System AM-1 project (EOS-AM-1) nickel hydrogen cell life test being conducted under contract to National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) at the Lockheed Martin Missiles and Space (LMMS) facility in East Windsor, NJ; and at COMSAT Labs., Clarksburg, MD. The purpose of the tests is to verify that the EOS-AM-1 cell design can meet five years of real-time Low Earth Orbit (LEO) cycling. The tests include both real-time LEO and accelerated stress tests. At LMMS, the first real-time LEO simulated 99 minute orbital cycle started on February 7, 1994 and the test has been running continuously since that time, with 18202 LEO cycles completed as of September 1, 1997. Each cycle consists of a 64 minute charge (VT at 1.507 volts per cell. 1.06 C/D ratio, followed by 0.6 ampere trickle charge) and a 35 minute constant power discharge at 177 watts (22.5% DOD). At COMSAT, the accelerated stress test consists of 90 minute orbital cycles at 60% DOD with a 30 minute discharge at 60 amperes and a 60 minute charge at 40 amperes (VT at 1.54 volts per cell to 1.09 C/D ratio, followed by 0.6 ampere trickle charge). The real-time LEO life test battery consists of seven, 50AH (nameplate rating) Eagle-Picher, Inc. (EPI) Mantech cells manufactured into three. 3-cell pack assemblies (there are two place holder cells that are not part of the life test electrical circuit). The test pack is configured to simulate the conductive thermal design of the spacecraft battery, including: conductive aluminum sleeves, 3-cell pack aluminum baseplate, and honeycomb panel all mounted to a liquid (-5 C) cold plate. The entire assembly is located in a thermal chamber operatina at +30 C. The accelerated stress test unit consists of five cells mounted in machined aluminum test sleeves and is operating at +10 C. The real-time LEO life test battery has met all performance requirements throuch the first 18,202 cycles, including: end of chargee and discharge cell voltages and voltace -radients; end of charge and discharge cell pressures; within cell and between cell temperature gradients; discharge capacity; current and power levels; and all charge parameters. The accelerated stress test battery has completed 11,998 cycles when the test was terminated. The stress test unit met all test parameters. This paper reports battery performances as a function of cycle life for both the real time LEO and the accelerated life test regimes.

  15. EOS-AM1 Nickel Hydrogen Cell Interim Life Test Report

    NASA Technical Reports Server (NTRS)

    Bennett, Charles W.; Keys, D. J.; Rao, G. M.; Wannemacher, H. E.; Vaidyanathan, Hari

    1998-01-01

    This paper reports the interim results Earth Observing System AM-1 project (EOS-AM-1) nickel hydrogen cell life test being conducted under contract to National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) at the Lockheed Martin Missiles and Space (LMMS) facility in East Windsor, NJ; and at COMSAT Labs., Clarksburg, MD. The purpose of the tests is to verify that the EOS-AM-1 cell design can meet five years of real-time Low Earth Orbit (LEO) cycling. The tests include both real-time LEO and accelerated stress tests. At LMMS, the first real-time LEO simulated 99 minute orbital cycle started on February 7, 1994 and the test has been running continuously since that time, with 18202 LEO cycles completed as of September 1, 1997. Each cycle consists of a 64-minute charge (VT at 1,507 volts per cell, 1.06 C/D ratio, followed by 0.6 ampere trickle charge) and a 35 minute constant power discharge at 177 watts (22.5 percent DOD). At COMSAT, the accelerated stress test consists of 90 minute orbital cycles at 60 percent DOD with a 30 minute discharge at 60 amperes and a 60 minute charge at 40 amperes (VT at 1.54 volts per cell to 1.90 C/D ratio, followed by 0.6 ampere trickle charge). The real-time LEO life test battery consists of seven, 50AH (nameplate rating) Eagle-Picher, Inc. (EPI) Mantech cells manufactured into three, 3-cell pack assemblies (there are two place holder cells that are not part of the life test electrical circuit). The test pack is configured to simulate the conductive thermal design of the spacecraft battery, including: conductive aluminum sleeves, 3-cell pack aluminum baseplate, and honeycomb panel all mounted to a liquid (minus 5 deg) cold plate. The entire assembly is located in a thermal chamber operating at plus 3 deg. The accelerated stress test unit consists of five cells mounted in machined aluminum test sleeves and is operating at plus 10 deg. The real-time LEO life test battery has met all performance requirements through the first 18,202 cycles, including: end of charge and discharge cell voltages and voltage gradients; end of charge and discharge cells pressures; within cell and between cell temperature gradients dischare capacity; current and power levels; and all charge parameters. The accelerated stress test battery has completed 11998 cycles when the test was terminated. The stress test unit met all test parameters. This paper reports battery performances as a function of cycle life for both the real-time LEO and the accelerated life test regimes.

  16. Cardiorespiratory responses and blood lactate during an experimental run-cycle transition in duathletes.

    PubMed

    Galy, O; Hue, O; Boussana, A; Le Gallais, D; Prefaut, C

    2002-04-01

    The aim of this study was to determine the effects of a prior run on the cardiorespiratory responses measured during a subsequent cycle segment. Twelve duathletes underwent three successive laboratory trials at an interval of one week: 1) an incremental cycle test, 2) 20 min of running followed by 20 min of cycling (RC), and 3) 20 min of control cycling (C) at the same intensity as the cycling segment of RC. Ventilatory data were collected every minute using a breath-by-breath automated system. Blood samples were collected to measure venous blood lactate concentration, [La], at rest, after the running and cycling segments of RC and after C. The results showed that the C segment of RC had significantly higher VE, VE/VO2, f and HR than C alone and significantly lower VT (p < 0.05) than C alone. Moreover, steady state during C of RC was reached at the 2nd min for VO2, VE, VCO2, VE/VO2, VE/VCO2, and VdT; at the 4th min for R and HR, and at the 5th min for f. The C of RC induced a significant increase in [La] in comparison with C alone. We concluded that the first minute of cycling after running during an RC trial induced specific metabolic and cardiorespiratory responses.

  17. Ventilatory threshold may be a more specific measure of aerobic capacity than peak oxygen consumption rate in persons with stroke.

    PubMed

    Boyne, Pierce; Reisman, Darcy; Brian, Michael; Barney, Brian; Franke, Ava; Carl, Daniel; Khoury, Jane; Dunning, Kari

    2017-03-01

    After stroke, aerobic deconditioning can have a profound impact on daily activities. This is usually measured by the peak oxygen consumption rate achieved during exercise testing (VO2-peak). However, VO2-peak may be distorted by motor function. The oxygen uptake efficiency slope (OUES) and VO2 at the ventilatory threshold (VO2-VT) could more specifically assess aerobic capacity after stroke, but this has not been tested. To assess the differential influence of motor function on three measures of aerobic capacity (VO2-peak, OUES, and VO2-VT) and to evaluate the inter-rater reliability of VO2-VT determination post-stroke. Among 59 persons with chronic stroke, cross-sectional correlations with motor function (comfortable gait speed [CGS] and lower extremity Fugl-Meyer [LEFM]) were compared between the different aerobic capacity measures, after adjustment for covariates, in order to isolate any distorting effect of motor function. Reliability of VO2-VT determination between three raters was assessed with intra-class correlation (ICC). CGS was moderately correlated with VO2-peak (r = 0.52, p < 0.0001) and weakly correlated with OUES (r = 0.41, p = 0.002) and VO2-VT (r = 0.37, p = 0.01). LEFM was weakly correlated with VO2-peak (r = 0.26, p = 0.055) and very weakly correlated with OUES (r = 0.19, p = 0.17) and VO2-VT (r = 0.14, p = 0.31). Compared to VO2-peak, VO2-VT was significantly less correlated with CGS (r difference = -0.16, p = 0.02). Inter-rater reliability of VO2-VT determination was high (ICC: 0.93, 95% CI: 0.89-0.96). Motor dysfunction appears to artificially lower measured aerobic capacity. VO2-VT seemed to be less distorted than VO2-peak and had good inter-rater reliability, so it may provide more specific assessment of aerobic capacity post-stroke.

  18. Performance of Digital Communications over Selective Fading Channels.

    DTIC Science & Technology

    1983-09-01

    and we assume that the "" receiver has compensated for the mean path delay td . Equivalently, we let d - : - 0 in order to establish a time reference...Pv dl g(V v( 4bd 2G2 E 211v/T2 (3.37) N0 4’. .4 which implies that iv is the key parameter in determining the signal-to-noise ratio for single-pulse...in (4.8) are defined by R-77 7777 7777,077 7-7.7 70 jnht(-b )/ Td Kv(h,bi,:) = , v(t) v(t-4) e h i dt (4.10a) and R=hbit v(t) v(t+T-4) e•j uh t (1- b

  19. Ventricular tachycardia storm originating from interventricular septum successfully treated with surgical cryoablation with electroanatomic and electrophysiological mapping before dual valve replacement.

    PubMed

    Kawamura, Iwanari; Fukamizu, Seiji; Miyazawa, Satoshi; Hojo, Rintaro; Ito, Fusahiko; Watanabe, Masazumi; Nishizaki, Mitsuhiro; Sakurada, Harumizu; Hiraoka, Masayasu

    2018-02-01

    A 58-year-old man with dilated cardiomyopathy was admitted with heart failure. He had a history of two catheter ablation procedures for ventricular tachycardia (VT) originating from the intraventricular septum (IVS). Before dual valve replacement (DVR), he suffered a VT storm. An electrophysiological study revealed an extended low-voltage area at the IVS with the exit of the induced VT at the anterior side. Radiofrequency application was performed at the VT exit as a landmark for surgical cryoablation (SA). During the DVR, SA was performed at the IVS using this landmark. After SA, the patient had no ventricular tachyarrhythmia.

  20. Better GGA and meta-GGA Functionals: VT84, meta-VMT, meta-VT84

    NASA Astrophysics Data System (ADS)

    Vela, Alberto; Martin Del Campo, J.; Gazquez, J. L.; Trickey, S. B.

    2011-03-01

    The goal of fast DFT calculations on large families of highly complicated systems (e.g. large clusters, biomolecules) implicitly conflicts with the heavy emphasis of recent years on inclusion of exact exchange. In response we have worked on improving non-empirical GGA X functionals. Here we report extension of our VMT GGA functional (J. Chem. Phys. 130 244103 (2009)) to satisfy a relevant asymptotic constraint, yielding the VT{84} X functional. With the PBE C functional, VT{84} gives about 10% improvement over VMT in energetics on the G3 223 molecule set. At the meta-GGA level of complexity, we have both meta-VMT and meta-{84}. The former is about 10% better on the G3 set than the TPSS meta-GGA, while meta-VT{84} gives roughly 10% further improvement over meta-VMT. Details of these assessments, including improvements in chemical shifts, will be presented. SBT acknowledges US DOE Grant DE-SC0002139.

  1. Ventricular tachycardia in post-myocardial infarction patients. Results of surgical therapy.

    PubMed

    Viganò, M; Martinelli, L; Salerno, J A; Minzioni, G; Chimienti, M; Graffigna, A; Goggi, C; Klersy, C; Montemartini, C

    1986-05-01

    This report addresses the problems related to surgical treatment of post-infarction ventricular tachycardia (VT) and is based on a 5 year experience of 36 consecutive patients. In every case the arrhythmia was unresponsive to pharmacological therapy. All patients were operated on after the completion of a diagnostic protocol including preoperative endocardial, intra-operative epi-endocardial mapping, the latter performed automatically when possible. Surgical techniques were: classical Guiraudon's encircling endocardial ventriculotomy (EEV); partial EEV, endocardial resection (ER); cryoablation or a combination of these procedures. The in-hospital mortality (30 days) was 8.3% (3 patients). During the follow-up period (1-68 months), 3 patients (9%) died of cardiac but not VT related causes. Of the survivors, 92% are VT-free. We consider electrophysiologically guided surgery a safe and reliable method for the treatment of post-infarction VT and suggest its more extensive use. We stress the importance of automatic mapping in pleomorphic and non-sustained VT, and the necessity of tailoring the surgical technique to the characteristics of each case.

  2. Catheter ablation of fatal ventricular tachyarrhythmias storm in acute coronary syndrome--role of Purkinje fiber network.

    PubMed

    Enjoji, Yoshihisa; Mizobuchi, Masahiro; Muranishi, Hiromi; Miyamoto, Chinae; Utsunomiya, Makoto; Funatsu, Atsushi; Kobayashi, Tomoko; Nakamura, Shigeru

    2009-12-01

    Ventricular fibrillation (VF) or ventricular tachycardia (VT) storm is a life-threatening arrhythmia. Antiarrhythmic drugs (AADs) are not necessarily effective to rescue life from such conditions. Catheter ablation (CA) targeting triggering premature ventricular contractions (PVCs) of VF or VT that originates from Purkinje fiber network (PFN) is reported to be effective, especially in idiopathic patients. However, in condition of acute coronary syndrome (ACS), the efficacy of CA is not well understood. To clarify the usefulness of CA as an alternative way to AADs, we performed CA in four patients with VF or VT storm. The Purkinje potential was seen just before the myocardial ventricular wave during sinus rhythm that became more prominent and double components during the initiating PVC at the targeted area. Following CA, spontaneous episodes of VF or VT were no longer observed. CA is an efficacious way to bail out PFN-related VF or VT storm even in ACS.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xie, J. L.; Shi, X. J.; Xu, J. C., E-mail: xiejinglan@ynao.ac.cn

    Based on continuous wavelet transformation analysis, the daily solar mean magnetic field (SMMF) from 1975 May 16 to 2014 July 31 is analyzed to reveal its rotational behavior. Both the recurrent plot in Bartels form and the continuous wavelet transformation analysis show the existence of rotational modulation in the variation of the daily SMMF. The dependence of the rotational cycle lengths on solar cycle phase is also studied, which indicates that the yearly mean rotational cycle lengths generally seem to be longer during the rising phase of solar cycles and shorter during the declining phase. The mean rotational cycle lengthmore » for the rising phase of all of the solar cycles in the considered time is 28.28 ± 0.67 days, while for the declining phase it is 27.32 ± 0.64 days. The difference of the mean rotational cycle lengths between the rising phase and the declining phase is 0.96 days. The periodicity analysis, through the use of an auto-correlation function, indicates that the rotational cycle lengths have a significant period of about 10.1 years. Furthermore, the cross-correlation analysis indicates that there exists a phase difference between the rotational cycle lengths and solar activity.« less

  4. Hypercapnic acidosis modulates inflammation, lung mechanics, and edema in the isolated perfused lung.

    PubMed

    De Smet, Hilde R; Bersten, Andrew D; Barr, Heather A; Doyle, Ian R

    2007-12-01

    Low tidal volume (V(T)) ventilation strategies may be associated with permissive hypercapnia, which has been shown by ex vivo and in vivo studies to have protective effects. We hypothesized that hypercapnic acidosis may be synergistic with low V(T) ventilation; therefore, we studied the effects of hypercapnia and V(T) on unstimulated and lipopolysaccharide-stimulated isolated perfused lungs. Isolated perfused rat lungs were ventilated for 2 hours with low (7 mL/kg) or moderately high (20 mL/kg) V(T) and 5% or 20% CO(2), with lipopolysaccharide or saline added to the perfusate. Hypercapnia resulted in reduced pulmonary edema, lung stiffness, tumor necrosis factor alpha (TNF-alpha) and interleukin 6 (IL-6) in the lavage and perfusate. The moderately high V(T) did not cause lung injury but increased lavage IL-6 and perfusate IL-6 as well as TNF-alpha. Pulmonary edema and respiratory mechanics improved, possibly as a result of a stretch-induced increase in surfactant turnover. Lipopolysaccharide did not induce significant lung injury. We conclude that hypercapnia exerts a protective effect by modulating inflammation, lung mechanics, and edema. The moderately high V(T) used in this study stimulated inflammation but paradoxically improved edema and lung mechanics with an associated increase in surfactant release.

  5. Vasculotide reduces endothelial permeability and tumor cell extravasation in the absence of binding to or agonistic activation of Tie2.

    PubMed

    Wu, Florence T H; Lee, Christina R; Bogdanovic, Elena; Prodeus, Aaron; Gariépy, Jean; Kerbel, Robert S

    2015-06-01

    Angiopoietin-1 (Ang1) activation of Tie2 receptors on endothelial cells (ECs) reduces adhesion by tumor cells (TCs) and limits junctional permeability to TC diapedesis. We hypothesized that systemic therapy with Vasculotide (VT)-a purported Ang1 mimetic, Tie2 agonist-can reduce the extravasation of potentially metastatic circulating TCs by similarly stabilizing the host vasculature. In vitro, VT and Ang1 treatments impeded endothelial hypermeability and the transendothelial migration of MDA-MB-231∙LM2-4 (breast), HT29 (colon), or SN12 (renal) cancer cells to varying degrees. In mice, VT treatment inhibited the transit of TCs through the pulmonary endothelium, but not the hepatic or lymphatic endothelium. In the in vivo LM2-4 model, VT monotherapy had no effect on primary tumors, but significantly delayed distant metastatic dissemination to the lungs. In the post-surgical adjuvant treatment setting, VT therapeutically complemented sunitinib therapy, an anti-angiogenic tyrosine kinase inhibitor which limited the local growth of residual disease. Unexpectedly, detailed investigations into the putative mechanism of action of VT revealed no evidence of Tie2 agonism or Tie2 binding; alternative mechanisms have yet to be determined. © 2015 The Authors. Published under the terms of the CC BY 4.0 license.

  6. Spectral emission measurements of lithium on the lithium tokamak experiment.

    PubMed

    Gray, T K; Biewer, T M; Boyle, D P; Granstedt, E M; Kaita, R; Maingi, R; Majeski, R P

    2012-10-01

    There has been a long-standing collaboration between ORNL and PPPL on edge and boundary layer physics. As part of this collaboration, ORNL has a large role in the instrumentation and interpretation of edge physics in the lithium tokamak experiment (LTX). In particular, a charge exchange recombination spectroscopy (CHERS) diagnostic is being designed and undergoing staged testing on LTX. Here we present results of passively measured lithium emission at 5166.89 A in LTX in anticipation of active spectroscopy measurements, which will be enabled by the installation of a neutral beam in 2013. Preliminary measurements are made in transient LTX plasmas with plasma current, I(p) < 70 kA, ohmic heating power, P(oh) ∼ 0.3 MW and discharge lifetimes of 10-15 ms. Measurements are made with a short focal length spectrometer and optics similar to the CHERS diagnostics on NSTX [R. E. Bell, Rev. Sci. Instrum. 68(2), 1273-1280 (1997)]. These preliminary measurements suggest that even without the neutral beam for active spectroscopy, there is sufficient passive lithium emission to allow for line-of-sight profile measurements of ion temperature, T(i); toroidal velocity and v(t). Results show peak T(i) = 70 eV and peak v(t) = 45 km/s were reached 10 ms into the discharge.

  7. Streptococcus pyogenes strains containing emm12 and emm55 possess a novel gene coding for distantly related SIC protein.

    PubMed

    Hartas, J; Sriprakash, K S

    1999-01-01

    Streptococcus pyogenes infection and acute glomerulonephritis (AGN), a non-suppurtave disease, are endemic in the Aboriginal people of the Northern Territory (NT) of Australia. Vir typing, a locus-specific polymerase chain reaction (PCR)-based typing method [Gardiner, Hartas, Currie et al PCR Meth Appl 1995 4: 288-93], has revealed high divergence among the NT streptococcal strains. A total of 76 Vir types (VTs) representing about 95% of the NT isolates were screened for sic, a gene for streptococcal inhibitor of complement function, by PCR and hybridization. This revealed that seven VTs are positive for sic, and there are two classes of the gene: those closely related to sic (CRS) originally described by Akesson, Sjoholm & Bjorck [ J. Biol. Chem. 1996 271: 1081-8] and those distantly related to sic (DRS). Among the CRS-positive VTs, VT16, VT78 and VT91 have emm (gene for M protein) encoding type 1 M protein or related specificity, and VT8 and VT101 contain emm57 or related alleles. Chromosomal location of CRS in emm57 is different from that in emm1 or related strains. The DRS-positive VT18 and VT52 contained emm55 and emm12 respectively, which are phylogenetically related. Strains of S. pyogenes types 1, 12, 55 and 57 are known to be associated with AGN. Restricted distribution of CRS and DRS among the M types historically associated with AGN suggests that these sic alleles may have a role in AGN pathogenesis. Copyright 1999 Academic Press.

  8. In Silico Template Selection of Short Antimicrobial Peptide Viscotoxin for Improving Its Antimicrobial Efficiency in Development of Potential Therapeutic Drugs.

    PubMed

    Senthilkumar, B; Rajasekaran, R

    2017-03-01

    Rapid increase in antibiotic resistance has posed a worldwide threat, due to increased mortality, morbidity, and expenditure caused by antibiotic-resistant microbes. Recent development of the antimicrobial peptides like viscotoxin (Vt) has been successfully comprehended as a substitute for classical antibiotics. A structurally stable peptide, Vt can enhance antimicrobial property and can be used for various developmental purposes. Thus, structural stability among the antimicrobial peptides, Vt A1 (3C8P), A2 (1JMN), A3 (1ED0), B (1JMP), and C (1ORL) of Viscus album was computationally analyzed. In specific, the static confirmation of VtA3 showed high number of intramolecular interactions, along with an increase in hydrophobicity than others comparatively. Further, conformational sampling was used to analyze various geometrical parameters such as root mean square deviation, root mean square fluctuation, radius of gyration, and ovality which also revealed the structural stability of VtA3. Moreover, the statistically validated contours of surface area, lipophilicity, and distance constraints of disulfide bonds also supported the priority of VtA3 with respect to stability. Finally, the functional activity of peptides was accessed by computing their free energy of membrane association and membrane interactions, which defined VtA3 as functionally stable. Currently, peptide-based antibiotics and nanoparticles have attracted the pharmaceutical industries for their potential therapeutic applications. Thereby, it is proposed that viscotoxin A3 (1ED0) could be used as a preeminent template for scaffolding potentially efficient antimicrobial peptide-based drugs and nanomaterials in future.

  9. Decreased lung compliance increases preload dynamic tests in a pediatric acute lung injury model.

    PubMed

    Erranz, Benjamín; Díaz, Franco; Donoso, Alejandro; Salomón, Tatiana; Carvajal, Cristóbal; Torres, María Fernanda; Cruces, Pablo

    2015-01-01

    Preload dynamic tests, pulse pressure variation (PPV) and stroke volume variation (SVV) have emerged as powerful tools to predict response to fluid administration. The influence of factors other than preload in dynamic preload test is currently poorly understood in pediatrics. The aim of our study was to assess the effect of tidal volume (VT) on PPV and SVV in the context of normal and reduced lung compliance in a piglet model. Twenty large-white piglets (5.2±0.4kg) were anesthetized, paralyzed and monitored with pulse contour analysis. PPV and SVV were recorded during mechanical ventilation with a VT of 6 and 12mL/kg (low and high VT, respectively), both before and after tracheal instillation of polysorbate 20. Before acute lung injury (ALI) induction, modifications of VT did not significantly change PPV and SVV readings. After ALI, PPV and SVV were significantly greater during ventilation with a high VT compared to a low VT (PPV increased from 8.9±1.2 to 12.4±1.1%, and SVV from 8.5±1.0 to 12.7±1.2%, both P<0.01). This study found that a high VT and reduced lung compliance due to ALI increase preload dynamic tests, with a greater influence of the latter. In subjects with ALI, lung compliance should be considered when interpreting the preload dynamic tests. Copyright © 2015 Sociedad Chilena de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. Eruption Forecasting in Alaska: A Retrospective and Test of the Distal VT Model

    NASA Astrophysics Data System (ADS)

    Prejean, S. G.; Pesicek, J. D.; Wellik, J.; Cameron, C.; White, R. A.; McCausland, W. A.; Buurman, H.

    2015-12-01

    United States volcano observatories have successfully forecast most significant US eruptions in the past decade. However, eruptions of some volcanoes remain stubbornly difficult to forecast effectively using seismic data alone. The Alaska Volcano Observatory (AVO) has responded to 28 eruptions from 10 volcanoes since 2005. Eruptions that were not forecast include those of frequently active volcanoes with basaltic-andesite magmas, like Pavlof, Veniaminof, and Okmok volcanoes. In this study we quantify the success rate of eruption forecasting in Alaska and explore common characteristics of eruptions not forecast. In an effort to improve future forecasts, we re-examine seismic data from eruptions and known intrusive episodes in Alaska to test the effectiveness of the distal VT model commonly employed by the USGS-USAID Volcano Disaster Assistance Program (VDAP). In the distal VT model, anomalous brittle failure or volcano-tectonic (VT) earthquake swarms in the shallow crust surrounding the volcano occur as a secondary response to crustal strain induced by magma intrusion. Because the Aleutian volcanic arc is among the most seismically active regions on Earth, distinguishing distal VT earthquake swarms for eruption forecasting purposes from tectonic seismicity unrelated to volcanic processes poses a distinct challenge. In this study, we use a modified beta-statistic to identify pre-eruptive distal VT swarms and establish their statistical significance with respect to long-term background seismicity. This analysis allows us to explore the general applicability of the distal VT model and quantify the likelihood of encountering false positives in eruption forecasting using this model alone.

  11. Effects of Analgesic Use on Inflammation and Hematology in a Murine Model of Venous Thrombosis

    PubMed Central

    Hish, Gerald A; Diaz, Jose A; Hawley, Angela E; Myers, Daniel D; Lester, Patrick A

    2014-01-01

    Venous thrombosis (VT) is a significant cause of morbidity and mortality in humans. Surgical animal models are crucial in studies investigating the pathogenesis of this disease and evaluating VT therapies. Because inflammation is critical to both the development and resolution of VT, analgesic medications have the potential to adversely affect multiple parameters of interest in VT research. The objective of this study was to determine how several common analgesics affect key variables in a murine ligation model of deep vein thrombosis. Male C57BL/6 mice were randomly assigned to receive either local (bupivacaine) or systemic parenteral analgesia (buprenorphine, tramadol, or carprofen) or 0.9% NaCl (control). All mice underwent laparotomy and ligation of the inferior vena cava, and treatment was continued until euthanasia at 6 or 48 h after surgery. Analysis of harvested tissues and blood included: hematology, thrombus weight, serum and vein-wall cytokines (IL1β, IL6, IL10, TNFα), soluble P-selectin, and vein-wall leukocyte infiltration. Compared with 0.9% NaCl, all of the analgesics affected multiple parameters important to VT research. Carprofen and tramadol affected the most parameters and should not be used in murine models of VT. Although they affected fewer parameters, a single dose of bupivacaine increased thrombus weight at 6 h, and buprenorphine was associated with reduced vein wall macrophages at 48 h. Although we cannot recommend the use of any of the evaluated analgesic dosages in this mouse model of VT, buprenorphine merits additional investigation to ensure the highest level of laboratory animal care and welfare. PMID:25255071

  12. Ventricular antitachycardia pacing therapy in patients with heart failure implanted with a cardiac resynchronization therapy defibrillator device: Efficacy, safety, and impact on mortality.

    PubMed

    Landolina, Maurizio; Lunati, Maurizio; Boriani, Giuseppe; Pietro Ricci, Renato; Proclemer, Alessandro; Facchin, Domenico; Rordorf, Roberto; Morani, Giovanni; Maines, Massimiliano; Gasparini, Gianni; Molon, Giulio; Turrini, Pietro; Gasparini, Maurizio

    2016-02-01

    Cardiac resynchronization therapy defibrillator can terminate ventricular tachycardia (VT) and fast VT (FVT) via antitachycardia pacing (ATP). We evaluated efficacy and safety of ATP, whether ATP induces ventricular arrhythmias after inappropriate ATP or atrial fibrillation (AF) after appropriate ATP, and whether ATP is associated with mortality. A total of 1404 patients with a cardiac resynchronization therapy defibrillator were followed in a prospective multicenter observational research. All-cause mortality rates were estimated in patient subgroups in order to uncouple the trigger (VT/FVT or other rhythms causing inappropriate detections) from ATP therapy. Over a median follow-up of 31 months, 2938 VT/FVT episodes were treated with ATP in 360 patients. The adjusted ATP success rate was 63% (95% confidence interval [CI] 57%-69%) on FVTs and 68% (95% CI 62%-74%) on VTs. Acceleration occurred in 55 (1.87%) and syncope in 4 (0.14%) of all ATP-treated episodes. In 14 true VT/FVT episodes in 5 patients, AF followed ATP therapy. In 4 episodes in 2 patients, VT followed ATP inappropriately applied during AF. Death rate per 100 patient-years was 5.6 (95% CI 4.3-7.5) in patients with appropriate ATP and 1.5 (95% CI 0.4-6.1) in patients with inappropriate ATP (P = .045). ATP was effective in terminating VT/FVT episodes and displayed a good safety profile. ATP therapies by themselves did not increase death risk; prognosis was indeed better in patients without arrhythmic episodes, even if they received inappropriate ATP, than in patients with ATP on VT/FVT episodes. Adverse outcomes observed in patients receiving implantable cardioverter-defibrillator therapies are probably related to the arrhythmia itself, a marker of disease progression, rather than to adverse effects of ATP. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  13. Patterns of volcanotectonic seismicity and stress during the ongoing eruption of the Soufrière Hills Volcano, Montserrat (1995-2007)

    USGS Publications Warehouse

    Roman, D.C.; De Angelis, S.; Latchman, J.L.; White, Rickie

    2008-01-01

    The ongoing eruption of the Soufrière Hills Volcano, Montserrat, has been accompanied throughout by varying levels of high-frequency, ‘volcanotectonic’ (VT), seismicity. These earthquakes reflect the brittle response of the host rock to stresses generated within the magmatic system and thus reveal interesting and useful information about the structure of the volcanic conduit system and processes occurring within it. In general, systematic changes in the rate, location, and fault-plane solutions of VT earthquakes correspond to changes in the volcano's behavior, and indicate that the main conduit for the eruption is a dike or system of dikes trending NE–SW and centered beneath the eruptive vent. To date, the eruption has comprised three extrusive phases, separated by two ~ 1–2 year-long periods of residual activity. Prior to the start of each extrusive phase, VT earthquakes with fault-plane solution p-axes oriented perpendicular to inferred regional maximum compression dominate the data set, consistent with stresses induced by the inflation of the mid-level conduit system. ~ 90°-rotated VT fault-plane solutions are also observed preceding a change in eruption style from effusive to explosive in 1997. While increases in the rate of VT earthquakes precede eruption phase onsets, high rates of VT seismicity are also observed during the first period of residual activity and in this case appear to reflect the relaxation of host rock following withdrawal of magma from the mid-crustal system. Most VT earthquakes are located directly beneath the eruptive vent, although two ‘distal VT clusters’ were observed during the first six months of the eruption (late 1995–early 1996). Both of these distal clusters likely resulted from stresses generated during the establishment of the main conduit system.

  14. Expression of RXR, EcR, E75 and VtG mRNA levels in the hepatopancreas and ovary of the freshwater edible crab, Oziothelphusa senex senex (Fabricius, 1798) during different vitellogenic stages

    NASA Astrophysics Data System (ADS)

    Girish, B. P.; Swetha, CH.; Reddy, P. Sreenivasula

    2015-04-01

    The objective of the present study was to investigate the expression profile of retinoid X receptor ( RXR), ecdysone receptor ( EcR) and ecdysone inducible gene ( E75) in the hepatopancreas and ovary of Oziothelphusa senex senex during different vitellogenic stages. RXR, EcR and E75 complementary DNAs (cDNAs) were isolated from the ovaries, while vitellogenin ( VtG) cDNA was isolated from the hepatopancreas of vitellogenic female crab. Deduced amino acid sequence of the messenger RNAs (mRNAs) of RXR, EcR and E75 showed more than 80 % identity with their respective mRNAs of other brachyurans. VtG mRNA was not detected in the ovary throughout vitellogenic stages. RXR and EcR were significantly increased in the ovaries during vitellogenic stage I. The levels of EcR, E75 and VtG in the hepatopancreas elevated significantly during vitellogenic stages I and II, whereas the levels of RXR elevated only in vitellogenic stage I. During vitellogenic stage III, the levels of RXR, EcR and VtG in the hepatopancreas were significantly decreased. Immunoprecipitation analysis revealed the presence of VtG in the haemolymph, hepatopancreas and ovary extracts from the females but absent in haemolymph and hepatopancreas extract of males. It can be inferred that RXR, EcR and E75 are involved in the regulation of synthesis of VtG in hepatopancreas, whereas in ovary, it is hypothesized that they play an important role in the uptake of VtG from the haemolymph, probably by regulating the levels of vitellogenin receptor. These are the first data showing an association between the expression levels of RXR, EcR and E75 and vitellogenesis and provide an alternative molecular intervention mechanism to the traditional eyestalk ablation to induce vitellogenesis and ovarian maturation in crustaceans.

  15. Spectral analysis of 87-lead body surface signal-averaged ECGs in patients with previous anterior myocardial infarction as a marker of ventricular tachycardia.

    PubMed

    Hosoya, Y; Kubota, I; Shibata, T; Yamaki, M; Ikeda, K; Tomoike, H

    1992-06-01

    There were few studies on the relation between the body surface distribution of high- and low-frequency components within the QRS complex and ventricular tachycardia (VT). Eighty-seven signal-averaged ECGs were obtained from 30 normal subjects (N group) and 30 patients with previous anterior myocardial infarction (MI) with VT (MI-VT[+] group, n = 10) or without VT (MI-VT[-] group, n = 20). The onset and offset of the QRS complex were determined from 87-lead root mean square values computed from the averaged (but not filtered) ECG waveforms. Fast Fourier transform analysis was performed on signal-averaged ECG. The resulting Fourier coefficients were attenuated by use of the transfer function, and then inverse transform was done with five frequency ranges (0-25, 25-40, 40-80, 80-150, and 150-250 Hz). From the QRS onset to the QRS offset, the time integration of the absolute value of reconstructed waveforms was calculated for each of the five frequency ranges. The body surface distributions of these areas were expressed as QRS area maps. The maximal values of QRS area maps were compared among the three groups. In the frequency ranges of 0-25 and 150-250 Hz, there were no significant differences in the maximal values among these three groups. Both MI groups had significantly smaller maximal values of QRS area maps in the frequency ranges of 25-40 and 40-80 Hz compared with the N group. The MI-VT(+) group had significantly smaller maximal values in the frequency ranges of 40-80 and 80-150 Hz than the MI-VT(-) group. These three groups were clearly differentiated by the maximal values of the 40-80-Hz QRS area map. It was suggested that the maximal value of the 40-80-Hz QRS area map was a new marker for VT after anterior MI.

  16. Utility of a novel risk score for prediction of ventricular tachycardia and cardiac death in chronic Chagas disease - the SEARCH-RIO study

    PubMed Central

    Benchimol-Barbosa, P.R.; Tura, B.R.; Barbosa, E.C.; Kantharia, B.K.

    2013-01-01

    The SEARCH-RIO study prospectively investigated electrocardiogram (ECG)-derived variables in chronic Chagas disease (CCD) as predictors of cardiac death and new onset ventricular tachycardia (VT). Cardiac arrhythmia is a major cause of death in CCD, and electrical markers may play a significant role in risk stratification. One hundred clinically stable outpatients with CCD were enrolled in this study. They initially underwent a 12-lead resting ECG, signal-averaged ECG, and 24-h ambulatory ECG. Abnormal Q-waves, filtered QRS duration, intraventricular electrical transients (IVET), 24-h standard deviation of normal RR intervals (SDNN), and VT were assessed. Echocardiograms assessed left ventricular ejection fraction. Predictors of cardiac death and new onset VT were identified in a Cox proportional hazard model. During a mean follow-up of 95.3 months, 36 patients had adverse events: 22 new onset VT (mean±SD, 18.4±4‰/year) and 20 deaths (26.4±1.8‰/year). In multivariate analysis, only Q-wave (hazard ratio, HR=6.7; P<0.001), VT (HR=5.3; P<0.001), SDNN<100 ms (HR=4.0; P=0.006), and IVET+ (HR=3.0; P=0.04) were independent predictors of the composite endpoint of cardiac death and new onset VT. A prognostic score was developed by weighting points proportional to beta coefficients and summing-up: Q-wave=2; VT=2; SDNN<100 ms=1; IVET+=1. Receiver operating characteristic curve analysis optimized the cutoff value at >1. In 10,000 bootstraps, the C-statistic of this novel score was non-inferior to a previously validated (Rassi) score (0.89±0.03 and 0.80±0.05, respectively; test for non-inferiority: P<0.001). In CCD, surface ECG-derived variables are predictors of cardiac death and new onset VT. PMID:24270912

  17. [Relevance of Vascular Trauma in Trauma Care - Impact on Clinical Course and Mortality].

    PubMed

    Lech, L; Jerkku, T; Kanz, K-G; Wierer, M; Mutschler, W; Koeppel, T A; Lefering, R; Banafsche, R

    2016-10-01

    There is a lack of evidence as to the relevance of vascular trauma (VT) in patients with severe injuries. Therefore, we reviewed registry data in the present study in order to systematically objectify the effect of VT in these patients. This study aimed to provide an adequate picture of the relevance of vascular trauma and to identify adverse prognostic factors. In a retrospective analysis of records from the TraumaRegister DGU® (TR-DGU) in two subgroups with moderate and severe VT, we examined the records for differences in terms of morbidity, mortality, follow-up and prognostic parameters compared to patients without VT with the same ISS. From a total of 42,326 patients, 2,961 (7 %) had a VT, and in 2,437 cases a severe VT (AIS ≥ 3) was diagnosed (5.8 %). In addition to a higher incidence of shock and a 2 to 3-fold increase in fluid replacement and erythrocyte transfusion, patients with severe VT had a 60 % higher rate of multiple organ failure, and in-hospital mortality was twice as high (33.8 %). The massively increased early mortality (8.0 vs. 25.2 %) clearly illustrates how severely injured patients are placed at risk by the presence of a relevant VT with a comparable ISS. In our opinion, due to an unexpected poor prognosis in the TR-DGU data for vascular injuries, increased attention is required in the care of severely injured patients. Based on our comprehensive analysis of negative prognostic factors, a further adjustment to the standards of vascular medicine could be advisable. The influence of the level of care provided by the admitting hospital and the relevance of a further hospital transfer to prognosis and clinical outcome is currently being analysed. Georg Thieme Verlag KG Stuttgart · New York.

  18. Mechanical ventilation with high tidal volume induces inflammation in patients without lung disease.

    PubMed

    Pinheiro de Oliveira, Roselaine; Hetzel, Marcio Pereira; dos Anjos Silva, Mauro; Dallegrave, Daniele; Friedman, Gilberto

    2010-01-01

    Mechanical ventilation (MV) with high tidal volumes may induce or aggravate lung injury in critical ill patients. We compared the effects of a protective versus a conventional ventilatory strategy, on systemic and lung production of tumor necrosis factor-alpha (TNF-alpha) and interleukin-8 (IL-8) in patients without lung disease. Patients without lung disease and submitted to mechanical ventilation admitted to one trauma and one general adult intensive care unit of two different university hospitals were enrolled in a prospective randomized-control study. Patients were randomized to receive MV either with tidal volume (VT) of 10 to 12 ml/kg predicted body weight (high VT group) (n = 10) or with VT of 5 to 7 ml/kg predicted body weight (low VT group) (n = 10) with an oxygen inspiratory fraction (FIO2) enough to keep arterial oxygen saturation >90% with positive end-expiratory pressure (PEEP) of 5 cmH2O during 12 hours after admission to the study. TNF-alpha and IL-8 concentrations were measured in the serum and in the bronchoalveolar lavage fluid (BALF) at admission and after 12 hours of study observation time. Twenty patients were enrolled and analyzed. At admission or after 12 hours there were no differences in serum TNF-alpha and IL-8 between the two groups. While initial analysis did not reveal significant differences, standardization against urea of logarithmic transformed data revealed that TNF-alpha and IL-8 levels in bronchoalveolar lavage (BAL) fluid were stable in the low VT group but increased in the high VT group (P = 0.04 and P = 0.03). After 12 hours, BALF TNF-alpha (P = 0.03) and BALF IL-8 concentrations (P = 0.03) were higher in the high VT group than in the low VT group. The use of lower tidal volumes may limit pulmonary inflammation in mechanically ventilated patients even without lung injury. NCT00935896.

  19. Relationship Between the Menstrual Cycle and Timing of Ovulation Revealed by New Protocols: Analysis of Data from a Self-Tracking Health App.

    PubMed

    Sohda, Satoshi; Suzuki, Kenta; Igari, Ichiro

    2017-11-27

    There are many mobile phone apps aimed at helping women map their ovulation and menstrual cycles and facilitating successful conception (or avoiding pregnancy). These apps usually ask users to input various biological features and have accumulated the menstrual cycle data of a vast number of women. The purpose of our study was to clarify how the data obtained from a self-tracking health app for female mobile phone users can be used to improve the accuracy of prediction of the date of next ovulation. Using the data of 7043 women who had reliable menstrual and ovulation records out of 8,000,000 users of a mobile phone app of a health care service, we analyzed the relationship between the menstrual cycle length, follicular phase length, and luteal phase length. Then we fitted a linear function to the relationship between the length of the menstrual cycle and timing of ovulation and compared it with the existing calendar-based methods. The correlation between the length of the menstrual cycle and the length of the follicular phase was stronger than the correlation between the length of the menstrual cycle and the length of the luteal phase, and there was a positive correlation between the lengths of past and future menstrual cycles. A strong positive correlation was also found between the mean length of past cycles and the length of the follicular phase. The correlation between the mean cycle length and the luteal phase length was also statistically significant. In most of the subjects, our method (ie, the calendar-based method based on the optimized function) outperformed the Ogino method of predicting the next ovulation date. Our method also outperformed the ovulation date prediction method that assumes the middle day of a mean menstrual cycle as the date of the next ovulation. The large number of subjects allowed us to capture the relationships between the lengths of the menstrual cycle, follicular phase, and luteal phase in more detail than previous studies. We then demonstrated how the present calendar methods could be improved by the better grouping of women. This study suggested that even without integrating various biological metrics, the dataset collected by a self-tracking app can be used to develop formulas that predict the ovulation day when the data are aggregated. Because the method that we developed requires data only on the first day of menstruation, it would be the best option for couples during the early stages of their attempt to have a baby or for those who want to avoid the cost associated with other methods. Moreover, the result will be the baseline for more advanced methods that integrate other biological metrics. ©Satoshi Sohda, Kenta Suzuki, Ichiro Igari. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 27.11.2017.

  20. Infection by verocytotoxin-producing Escherichia coli.

    PubMed Central

    Karmali, M A

    1989-01-01

    Verocytotoxin (VT)-producing Escherichia coli (VTEC) are a newly recognized group of enteric pathogens which are increasingly being recognized as common causes of diarrhea in some geographic settings. Outbreak studies indicate that most patients with VTEC infection develop mild uncomplicated diarrhea. However, a significant risk of two serious and potentially life-threatening complications, hemorrhagic colitis and the hemolytic uremic syndrome, makes VTEC infection a public health problem of serious concern. The main reservoirs of VTEC appear to be the intestinal tracts of animals, and foods of animal (especially bovine) origin are probably the principal sources for human infection. The term VT refers to a family of subunit exotoxins with high biological activity. Individual VTEC strains elaborate one or both of at least two serologically distinct, bacteriophage-mediated VTs (VT1 and VT2) which are closely related to Shiga toxin and are thus also referred to as Shiga-like toxins. The holotoxins bind to cells, via their B subunits, to a specific receptor which is probably the glycolipid, globotriosyl ceramide (Gb3). Binding is followed by internalization of the A subunit, which, after it is proteolytically nicked and reduced to the A1 fragment, inhibits protein synthesis in mammalian cells by inactivating 60S ribosomal subunits through selective structural modification of 28S ribosomal ribonucleic acid. The mechanism of VTEC diarrhea is still controversial, and the relative roles of locally acting VT and "attaching and effacing adherence" of VTEC to the mucosa have yet to be resolved. There is increasing evidence that hemolytic uremic syndrome and possibly hemorrhagic colitis result from the systemic action of VT on vascular endothelial cells. The role of antitoxic immunity in preventing the systemic complications of VTEC infection is being explored. Antibiotics appear to be contraindicated in the treatment of VTEC infection. The most common VTEC serotype associated with human disease is O157:H7, but over 50 different VT-positive O:H serotypes have now been identified. The best strategies for diagnosing human VTEC infection include testing for the presence of free VT in fecal filtrates and examining fecal cultures for VTEC by means of deoxyribonucleic acid probes that specify genes encoding VT1 and VT2. Both methods are currently confined to specialized laboratories and await commercial development for wider use. In the meantime, most laboratories should continue to screen for the most common human VTEC serotype, O157:H7, using a sorbitol-containing MacConkey medium. Images PMID:2644022

  1. Quantification of metabotropic glutamate subtype 5 receptors in the brain by an equilibrium method using 18F-SP203.

    PubMed

    Kimura, Yasuyuki; Siméon, Fabrice G; Zoghbi, Sami S; Zhang, Yi; Hatazawa, Jun; Pike, Victor W; Innis, Robert B; Fujita, Masahiro

    2012-02-01

    A new PET ligand, 3-fluoro-5-(2-(2-(18)F-(fluoromethyl)-thiazol-4-yl)ethynyl)benzonitrile (18F-SP203) can quantify metabotropic glutamate subtype 5 receptors (mGluR5) in human brain by a bolus injection and kinetic modeling. As an alternative approach to a bolus injection, binding can simply be measured as a ratio of tissue to metabolite-corrected plasma at a single time point under equilibrium conditions achieved by administering the radioligand with a bolus injection followed by a constant infusion. The purpose of this study was to validate the equilibrium method as an alternative to the standard kinetic method for measuring 18F-SP203 binding in the brain. Nine healthy subjects were injected with 18F-SP203 using a bolus plus constant infusion for 300 min. A single ratio of bolus-to-constant infusion (the activity of bolus equaled to that of infusion over 219 min) was applied to all subjects to achieve equilibrium in approximately 120 min. As a measure of ligand binding, we compared total distribution volume (VT) calculated by the equilibrium and kinetic methods in each scan. The equilibrium method calculated VT by the ratio of radioactivity in the brain to the concentration of 18F-SP203 in arterial plasma at 120 min, and the kinetic method calculated VT by a two-tissue compartment model using brain and plasma dynamic data from 0 to 120 min. VT obtained via the equilibrium method was highly correlated with VT obtained via kinetic modeling. Inter-subject variability of VT obtained via the equilibrium method was slightly smaller than VT obtained via the kinetic method. VT obtained via the equilibrium method was ~10% higher than VT obtained via the kinetic method, indicating a small difference between the measurements. Taken together, the results of this study show that using the equilibrium method is an acceptable alternative to the standard kinetic method when using 18F-SP203 to measure mGluR5. Although small differences in the measurements obtained via the equilibrium and kinetic methods exist, both methods consistently measured mGluR5 as indicated by the highly correlated VT values; the equilibrium method was slightly more precise, as indirectly measured by the smaller coefficient of variability across subjects. In addition, when using 18F-SP203, the equilibrium method is more efficient because it requires much less data. Copyright © 2011. Published by Elsevier Inc.

  2. Chlorination by-products in drinking water and menstrual cycle function.

    PubMed

    Windham, Gayle C; Waller, Kirsten; Anderson, Meredith; Fenster, Laura; Mendola, Pauline; Swan, Shanna

    2003-06-01

    We analyzed data from a prospective study of menstrual cycle function and early pregnancy loss to explore further the effects of trihalomethanes (THM) on reproductive end points. Premenopausal women ((italic)n(/italic) = 403) collected urine samples daily during an average of 5.6 cycles for measurement of steroid metabolites that were used to define menstrual parameters such as cycle and phase length. Women were asked about consumption of various types of water as well as other habits and demographics. A THM level was estimated for each cycle based on residence and quarterly measurements made by water utilities during a 90-day period beginning 60 days before the cycle start date. We found a monotonic decrease in mean cycle length with increasing total THM (TTHM) level; at > 60 microg/L, the adjusted decrement was 1.1 days [95% confidence interval (CI), -1.8 to -0.40], compared with less than or equal to 40 microg/L. This finding was also reflected as a reduced follicular phase length (difference -0.94 day; 95% CI, -1.6 to -0.24). A decrement in cycle and follicular phase length of 0.18 days (95% CI, -0.29 to -0.07) per 10 microg/L unit increase in TTHM concentration was found. There was little association with luteal phase length, menses length, or cycle variability. Examining the individual THMs by quartile, we found the greatest association with chlorodibromomethane or the sum of the brominated compounds. Incorporating tap water consumption showed a similar pattern of reduced cycle length with increasing TTHM exposure. These findings suggest that THM exposure may affect ovarian function and should be confirmed in other studies.

  3. Maximal oxygen uptake and cardiorespiratory response to maximal 400-m free swimming, running and cycling tests in competitive swimmers.

    PubMed

    Rodríguez, F A

    2000-06-01

    This study compared the cardiorespiratory response of trained swimmers to 400-m unimpeded front crawl swimming (SW), treadmill running (TR) and ergometer cycling (EC) maximal exercise tests, and evaluated the validity and specificity of a method to measure maximal aerobic power in swimming. Two series of experiments were conducted. In series A (n=15), comparisons were made between VO2peak and other cardiorespiratory variables in three maximal tests: after 400-m SW, and during incremental TR and EC. In series B, VO2 peak and related variables were measured after SW and during EC (n=33). No significant differences were observed between VO2peak and VE in the three modes of exercise, although SW values tended to be higher. After SW, maximal ventilatory response was characterized by higher tidal volumes (VT) and lower respiratory rates (fR) as compared with TR and EC. The highest heart rate values (fH) were also observed in TR, followed by EC and SW. In series B, no significant differences were observed either in peak VO2 or VE, but fH was also lower in SW. A maximal 400-m unimpeded freestyle SW test yields essentially equal or nonsignificantly higher peak VO2 and VE values than during maximal TR or EC tests in trained swimmers. The specific maximal cardiorespiratory response to the SW test is characterized by higher VT, lower fR, and lower fH. Breath-by-breath measurements during the immediate recovery after a 400-m voluntary maximal swim is proposed as a valid and specific test for directly measuring maximal metabolic parameters and evaluating specific maximal aerobic power in swimming.

  4. Approaching complete inhibition of P-glycoprotein at the human blood-brain barrier: an (R)-[11C]verapamil PET study.

    PubMed

    Bauer, Martin; Karch, Rudolf; Zeitlinger, Markus; Philippe, Cécile; Römermann, Kerstin; Stanek, Johann; Maier-Salamon, Alexandra; Wadsak, Wolfgang; Jäger, Walter; Hacker, Marcus; Müller, Markus; Langer, Oliver

    2015-05-01

    As P-glycoprotein (Pgp) inhibition at the blood-brain barrier (BBB) after administration of a single dose of tariquidar is transient, we performed positron emission tomography (PET) scans with the Pgp substrate (R)-[(11)C]verapamil in five healthy volunteers during continuous intravenous tariquidar infusion. Total distribution volume (VT) of (R)-[(11)C]verapamil in whole-brain gray matter increased by 273 ± 78% relative to baseline scans without tariquidar, which was higher than previously reported VT increases. During tariquidar infusion whole-brain VT was comparable to VT in the pituitary gland, a region not protected by the BBB, which suggested that we were approaching complete Pgp inhibition at the human BBB.

  5. Effect of Air Pollution on Menstrual Cycle Length—A Prognostic Factor of Women’s Reproductive Health

    PubMed Central

    Merklinger-Gruchala, Anna; Jasienska, Grazyna; Kapiszewska, Maria

    2017-01-01

    Air pollution can influence women’s reproductive health, specifically menstrual cycle characteristics, oocyte quality, and risk of miscarriage. The aim of the study was to assess whether air pollution can affect the length of the overall menstrual cycle and the length of its phases (follicular and luteal). Municipal ecological monitoring data was used to assess the air pollution exposure during the monitored menstrual cycle of each of 133 woman of reproductive age. Principal component analyses were used to group pollutants (PM10, SO2, CO, and NOx) to represent a source-related mixture. PM10 and SO2 assessed separately negatively affected the length of the luteal phase after standardization (b = −0.02; p = 0.03; b = −0.06; p = 0.02, respectively). Representing a fossil fuel combustion emission, they were also associated with luteal phase shortening (b = −0.32; p = 0.02). These pollutants did not affect the follicular phase length and overall cycle length, neither in single- nor in multi-pollutant models. CO and NOx assessed either separately or together as a traffic emission were not associated with overall cycle length or the length of cycle phases. Luteal phase shortening, a possible manifestation of luteal phase deficiency, can result from fossil fuel combustion. This suggests that air pollution may contribute to fertility problems in women. PMID:28726748

  6. In-series compliance of gastrocnemius muscle in cat step cycle: do spindles signal origin-to-insertion length?

    PubMed Central

    Elek, J; Prochazka, A; Hulliger, M; Vincent, S

    1990-01-01

    1. It has been claimed that stretch in the non-contractile (extramysial) portion of muscles is substantial, and may produce large discrepancies between the origin-to-insertion muscle length and the internal length variations 'seen' by muscle spindle endings. 2. In eight pentobarbitone-anaesthetized cats, we estimated stretch in the extramysial portion of medial gastrocnemius (MG) muscle with a method similar to the spindle null technique. 3. Length variations of MG previously monitored in a normal step cycle were reproduced with a computer-controlled length servo. The responses of test MG spindle endings were monitored in dorsal root filaments. Distributed stimulation of ventral root filaments, rate-modulated by the step-cycle EMG envelope, served to reproduce step-cycle forces. The filaments were selected so as to have no fusimotor action on the test spindle. 4. Spindle responses in active cycles were compared with those in passive cycles (stretch, but no distributed stimulation). In some cases concomitant tonic fusimotor stimulation was used to maintain spindle responsiveness throughout the cycle, both in active and passive trials. Generally, small discrepancies in spindle firing were seen. The passive trials were now repeated, with iterative adjustments of the length function, until the response matched the spindle firing profile in the active trial. The spindle 'saw' the same internal length change in the final passive trial as in the active trial. Any difference between the corresponding length profiles was attributed to extramysial displacement. 5. Extramysial displacement estimated in this was was maximal at short mean muscle lengths, reaching about 0.5 mm in a typical step cycle (force rising from 0 to 10 N). At longer mean muscle lengths where muscle force rose from say 2 to 12 N in the cycle, extramysial displacement was in the range 0.2-0.4 mm. 6. Except at very short lengths, the displacement was probably mainly tendinous. On this assumption, our results suggested that the stiffness of the MG tendinous compartment was force related, and about double that of cat soleus muscle at any given force. Calculations indicated that though the stretch was small, the MG tendon would store and release enough strain energy per cycle to contribute significantly to the E3 phase of the step cycle. The discrepancies in spindle firing were generally quite subtle, so we reject the claim that extramysial stretch poses a serious difficulty for inferences about fusimotion from chronic spindle afferent recordings. PMID:2148952

  7. [Effects of tillage at pre-planting of winter wheat and summer maize on leaf senescence of summer maize].

    PubMed

    Li, Xia; Zhang, Ji-wang; Ren, Bai-zhao; Fan, Xia; Dong, Shu-ting; Liu, Peng; Zhao, Bin

    2015-05-01

    This study explored the effects of different tillage treatments at pre-planting winter wheat and summer maize on leaf senescence physiological characteristics of summer maize in double cropping system. Zhengdan 958 was used as experimental material. Three tillage treatments, including rotary tillage before winter wheat seeding and no-tillage before summer maize seeding (RN), mold- board plow before winter wheat seeding and no-tillage before summer maize seeding (MN), and moldboard plow before winter wheat seeding and rotary tillage before summer maize seeding (MR), were designed to determine the effects of different tillage treatments on leaf area (LA) , leaf area reduction, photosynthetic pigments content, superoxide dismutase (SOD), catalase (CAT) and peroxidase (POD) activities and malondialdehyde (MDA) content in ear leaves of summer maize after tasselling (VT). LA of MN and MR were higher than that of RN from VT to 40 days after tasseling (VT + 40) and LA reduction of MR was the highest after VT + 40. As for MR, MN and NT, the photosynthetic pigments content got the maximum value at 20 days after tasselling (VT + 20) and then decreased, following the change of unimodal curve. At VT + 20, the contents of chlorophyll a in MR and MN were increased by 11.4% and 9.7%, the contents of chlorophyll b in MR and MN were increased by 14.9% and 15.9%, compared with RN. The soluble protein content in ear leaves decreased following the growth process in all treatments, and that of MR and MN remained 11.5% and 24.4% higher than that of RN from VT to VT + 40. SOD, CAT and POD activities of three treatments got the maximum values at VT + 20 and then decreased, following the change of unimodal curve. MDA content increased following the growth process in all treatments and that of RN always remained at high levels. Grain yields of MN and MR were 24.0% and 30.6% greater than that of RN, respectively. Grain yield of MR was 5.2% higher than that of MN. In conclusion, the ability of leaf senescence resistance of MN was improved, which was helpful to increase the yield of summer maize.

  8. Dual chamber arrhythmia detection in the implantable cardioverter defibrillator.

    PubMed

    Dijkman, B; Wellens, H J

    2000-10-01

    Dual chamber implantable cardioverter defibrillator (ICD) technology extended ICD therapy to more than termination of hemodynamically unstable ventricular tachyarrhythmias. It created the basis for dual chamber arrhythmia management in which dependable detection is important for treatment and prevention of both ventricular and atrial arrhythmias. Dual chamber detection algorithms were investigated in two Medtronic dual chamber ICDs: the 7250 Jewel AF (33 patients) and the 7271 Gem DR (31 patients). Both ICDs use the same PR Logic algorithm to interpret tachycardia as ventricular tachycardia (VT), supraventricular tachycardia (SVT), or dual (VT+ SVT). The accuracy of dual chamber detection was studied in 310 of 1,367 spontaneously occurring tachycardias in which rate criterion only was not sufficient for arrhythmia diagnosis. In 78 episodes there was a double tachycardia, in 223 episodes SVT was detected in the VT or ventricular fibrillation zone, and in 9 episodes arrhythmia was detected outside the boundaries of the PR Logic functioning. In 100% of double tachycardias the VT was correctly diagnosed and received priority treatment. SVT was seen in 59 (19%) episodes diagnosed as VT. The causes of inappropriate detection were (1) algorithm failure (inability to fulfill the PR

  9. Nasopharyngeal Pneumococcal Colonization and Impact of a Single Dose of 13-Valent Pneumococcal Conjugate Vaccine in Indian Children With HIV and Their Unvaccinated Parents.

    PubMed

    Arya, Bikas K; Bhattacharya, Sangeeta Das; Sutcliffe, Catherine G; Ganaie, Feroze; Bhaskar, Arun; Bhattacharyya, Subhasish; Niyogi, Swapan Kumar; Moss, William J; Panda, Samiran; Ravikumar, Kadahalli Lingegowda; Das, Ranjan Saurav; Mandal, Sutapa

    2018-05-01

    Human immunodeficiency virus (HIV) infection increases risk of invasive disease from Streptococcus pneumoniae. Pneumococcal conjugate vaccines (PCV) prevent invasive disease and acquisition of vaccine type (VT) pneumococcus in the nasopharynx. To look at the safety and impact of one dose of PCV13 on acquisition of VT pneumococcal carriage in Indian children with HIV. We conducted a cohort study in families of HIV-infected children (CLH) and families of HIV-uninfected children (HUC) in West Bengal. All children received one dose of PCV13. Nasopharyngeal swabs were collected from children and parents at baseline and 2 months after vaccination. One hundred and fifteen CLH and 47 HUC received one dose of PCV13. Fifty-eight percent of CLH were on antiretroviral therapy (ART), and the median nadir CD4 count was 287. There were no significant adverse events in either group. HUC had more VT colonization than CLH-55% versus 23% of all pneumococcal isolates. HIV infection doubled the risk of nonvaccine serotype colonization (P = 0.03). There was no difference in acquisition of VT isolates in CLH (4.4%) and HUC (4.5%) post-PCV13; however, older CLH (>5 years) had decreased clearance of VT strains. ART made no difference in pneumococcal colonization at baseline or after PCV13; however, CLH with higher nadir CD4 counts before starting ART were less likely to have VT colonization post-PCV13 (prevalence ratio, 0.2; 95% confidence interval: 0.1-0.5). While there was no difference in acquisition of VT nasopharyngeal carriage of pneumococcus in CLH and HUC after one dose of PCV13, earlier access to ART may impact response to PCV13 in CLH.

  10. Application of dead space fraction to titrate optimal positive end-expiratory pressure in an ARDS swine model.

    PubMed

    Bian, Weishuai; Chen, Wei; Chao, Yangong; Wang, Lan; Li, Liming; Guan, Jian; Zang, Xuefeng; Zhen, Jie; Sheng, Bo; Zhu, Xi

    2017-04-01

    This study aimed to apply the dead space fraction [ratio of dead space to tidal volume (VD/VT)] to titrate the optimal positive end-expiratory pressure (PEEP) in a swine model of acute respiratory distress syndrome (ARDS). Twelve swine models of ARDS were constructed. A lung recruitment maneuver was then conducted and the PEEP was set at 20 cm H 2 O. The PEEP was reduced by 2 cm H 2 O every 10 min until 0 cm H 2 O was reached, and VD/VT was measured after each decrement step. VD/VT was measured using single-breath analysis of CO 2 , and calculated from arterial CO 2 partial pressure (PaCO 2 ) and mixed expired CO 2 (PeCO 2 ) using the following formula: VD/VT = (PaCO 2 - PeCO 2 )/PaCO 2 . The optimal PEEP was identified by the lowest VD/VT method. Respiration and hemodynamic parameters were recorded during the periods of pre-injury and injury, and at 4 and 2 cm H 2 O below and above the optimal PEEP (Po). The optimal PEEP in this study was found to be 13.25±1.36 cm H 2 O. During the Po period, VD/VT decreased to a lower value (0.44±0.08) compared with that during the injury period (0.68±0.10) (P<0.05), while the intrapulmonary shunt fraction reached its lowest value. In addition, a significant change of dynamic tidal respiratory compliance and oxygenation index was induced by PEEP titration. These results indicate that minimal VD/VT can be used for PEEP titration in ARDS.

  11. Work of breathing during lung-protective ventilation in patients with acute lung injury and acute respiratory distress syndrome: a comparison between volume and pressure-regulated breathing modes.

    PubMed

    Kallet, Richard H; Campbell, Andre R; Dicker, Rochelle A; Katz, Jeffrey A; Mackersie, Robert C

    2005-12-01

    Pressure-control ventilation (PCV) and pressure-regulated volume-control (PRVC) ventilation are used during lung-protective ventilation because the high, variable, peak inspiratory flow rate (V (I)) may reduce patient work of breathing (WOB) more than the fixed V (I) of volume-control ventilation (VCV). Patient-triggered breaths during PCV and PRVC may result in excessive tidal volume (V(T)) delivery unless the inspiratory pressure is reduced, which in turn may decrease the peak V (I). We tested whether PCV and PRVC reduce WOB better than VCV with a high, fixed peak V (I) (75 L/min) while also maintaining a low V(T) target. Fourteen nonconsecutive patients with acute lung injury or acute respiratory distress syndrome were studied prospectively, using a random presentation of ventilator modes in a crossover, repeated-measures design. A target V(T) of 6.4 + 0.5 mL/kg was set during VCV and PRVC. During PCV the inspiratory pressure was set to achieve the same V(T). WOB and other variables were measured with a pulmonary mechanics monitor (Bicore CP-100). There was a nonsignificant trend toward higher WOB (in J/L) during PCV (1.27 + 0.58 J/L) and PRVC (1.35 + 0.60 J/L), compared to VCV (1.09 + 0.59 J/L). While mean V(T) was not statistically different between modes, in 40% of patients, V(T) markedly exceeded the lung-protective ventilation target during PRVC and PCV. During lung-protective ventilation, PCV and PRVC offer no advantage in reducing WOB, compared to VCV with a high flow rate, and in some patients did not allow control of V(T) to be as precise.

  12. Cellular Mechanism Underlying Hypothermia-Induced VT/VF in the Setting of Early Repolarization and the Protective Effect of Quinidine, Cilostazol and Milrinone

    PubMed Central

    Gurabi, Zsolt; Koncz, István; Patocskai, Bence; Nesterenko, Vladislav V.; Antzelevitch, Charles

    2014-01-01

    Background Hypothermia has been reported to induce ventricular tachycardia and fibrillation (VT/VF) in patients with early repolarization (ER) pattern. This study examines the cellular mechanisms underlying VT/VF associated with hypothermia in an experimental model of ER syndrome (ERS) and examines the effectiveness of quinidine, cilostazol and milrinone to prevent hypothermia-induced arrhythmias. Method and Results Transmembrane action potentials (AP) were simultaneously recorded from 2 epicardial and 1 endocardial site of coronary-perfused canine left-ventricular wedge preparations, together with a pseudo-ECG. A combination of NS5806 (3–10 µM) and verapamil (1µM) was used to pharmacologically model the genetic mutations responsible for ERS. Acetylcholine (3µM) was used to simulate increased parasympathetic tone, which is known to promote ER. In control, lowering the temperature of the coronary perfusate to induce mild hypothermia (32°C-34°C) resulted in increased J wave area on the ECG and accentuated epicardial AP notch but no arrhythmic activity. In the setting of ER, hypothermia caused further accentuation of the epicardial AP notch, leading to loss of the AP dome at some sites but not others, thus creating the substrate for development of phase-2-reentry and VT/VF. Addition of the Ito antagonist quinidine (5 µM) or the phosphodiesterase III inhibitors cilostazol (10 µM) or milrinone (5 µM), diminished the ER manifestations and prevented the hypothermia-induced phase 2 reentry and VT/VF. Conclusions Hypothermia leads to VT/VF in the setting of ER by exaggerating repolarization abnormalities, leading to development of phase-2-reentry. Quinidine, cilostazol and milrinone suppress the hypothermia-induced VT/VF by reversing the repolarization abnormalities. PMID:24429494

  13. QT/RR relationship in patients after remote anterior myocardial infarction with left ventricular dysfunction and different types of ventricular arrhythmias.

    PubMed

    Szydlo, Krzysztof; Trusz-Gluza, Maria; Wita, Krystian; Filipecki, Artur; Orszulak, Witold; Urbanczyk, Dagmara; Krauze, Jolanta; Kolasa, Jaroslaw; Tabor, Zbigniew

    2008-01-01

    QT/RR relationship was found to be both rate-dependent and rate-independent, what suggests the influence of autonomic drive and other not-autonomic related factors on it. The steeper QT/RR slope in patients after acute myocardial infarction (MI) was described, but the relationship to ventricular arrhythmias is unknown. The purpose of this study was to calculate differences in QT/RR relationship in patients after remote anterior MI with left ventricular dysfunction and different types of ventricular arrhythmias. The cohort of 95 patients (age: 63 +/- 11 years, LVEF: 35 +/- 9%) with previous anterior MI (mean 1.1 years) was divided into two well-matched groups-50 patients without episodes of ventricular tachycardia (VT) or ventricular fibrillation (VF) (NoVT/VF: 39 males, 64 +/- 12 years, LVEF 37 +/- 8%) and 45 patients with VT and/or VF (all with ICD implanted) (VT/VF: 35 males, 62 +/- 10 years, LVEF 34 +/- 10%). No true antiarrhythmics were used. QT/RR slope was calculated from 24-hour Holter ECG for the entire recording (E), daytime (D) and nighttime (N) periods. Groups did not differ in basic clinical data (age, LVEF, treatment). QT/RR slopes were steeper in VT/VF than in NoVT/VF group in all analyzed periods: E - 0.195 +/- 0.03 versus 0.15 +/- 0.03 (P < 0.001), N - 0.190 +/- 0.03 versus 0.138 +/- 0.03 (P < 0.001) and D - 0.200 +/- 0.04 versus 0.152 +/- 0.03 (P < 0.001). No significant day-to-night differences were found in both groups. Steeper QT/RR slope and complete lack of day-to-night differences in VT/VF patients show inappropriate QT adaptation to the heart rate changes. The prognostic significance of this parameter needs prospective studies.

  14. Endotoxaemia-augmented murine venous thrombosis is dependent on TLR-4 and ICAM-1, and potentiated by neutropenia.

    PubMed

    Obi, Andrea T; Andraska, Elizabeth; Kanthi, Yogendra; Kessinger, Chase W; Elfline, Megan; Luke, Cathy; Siahaan, Teruna J; Jaffer, Farouc A; Wakefield, Thomas W; Henke, Peter K

    2017-01-26

    Venous thromboembolism is a major cause of death during and immediately post-sepsis. Venous thrombosis (VT) is mediated by cell adhesion molecules and leukocytes, including neutrophil extracellular traps (NETs). Sepsis, or experimentally, endotoxaemia, shares similar characteristics and is modulated via toll like receptor 4 (TLR4). This study was undertaken to determine if endotoxaemia potentiates early stasis thrombogenesis, and secondarily to determine the role of VT TLR4, ICAM-1 and neutrophils (PMNs). Wild-type (WT), ICAM-1 -/- and TLR4 -/- mice underwent treatment with saline or LPS (10 mg/kg i. p.) alone, or followed by inferior vena cava (IVC) ligation to generate stasis VT. In vivo microscopy of leukocyte trafficking was performed in non-thrombosed mice, and tissue and plasma were harvested during early VT formation. Pre-thrombosis, circulating ICAM-1 was elevated and increased leukocyte adhesion and rolling occurred on the IVC of LPS-treated mice. Post-thrombosis, endotoxaemic mice formed larger, platelet-poor thrombi. Endotoxaemic TLR4 -/- mice did not have an augmented thrombotic response and exhibited significantly decreased circulating ICAM-1 compared to endotoxaemic WT controls. Endotoxaemic ICAM-1 -/- mice had significantly smaller thrombi compared to controls. Hypothesising that PMNs localised to the inflamed endothelium were promoting thrombosis, PMN depletion using anti-Ly6G antibody was performed. Paradoxically, VT formed without PMNs was amplified, potentially related to endotoxaemia induced elevation of PAI-1 and circulating FXIII, and decreased uPA. Endotoxaemia enhanced early VT occurs in a TLR-4 and ICAM-1 dependent fashion, and is potentiated by neutropenia. ICAM-1 and/or TLR-4 inhibition may be a unique strategy to prevent sepsis-associated VT.

  15. Dissociation of hemodynamic and electrocardiographic indexes of myocardial ischemia in pigs with hibernating myocardium and sudden cardiac death.

    PubMed

    Pizzuto, Matthew F; Suzuki, Gen; Banas, Michael D; Heavey, Brendan; Fallavollita, James A; Canty, John M

    2013-06-15

    Many survivors of sudden cardiac death (SCD) have normal global ventricular function and severe coronary artery disease but no evidence of symptomatic ischemia or infarction before the development of lethal ventricular arrhythmias, and the trigger for ventricular tachycardia (VT)/ventricular fibrillation (VF) remains unclear. We sought to identify the role of spontaneous ischemia and temporal hemodynamic factors preceding SCD using continuous telemetry of left ventricular (LV) pressure and the ECG for periods up to 5 mo in swine (n = 37) with hibernating myocardium who experience spontaneous VT/VF in the absence of heart failure or infarction. Hemodynamics and ST deviation at the time of VT/VF were compared with survivors with hibernating myocardium as well as sham controls. All episodes of VT/VF occurred during sympathetic activation and were initiated by single premature ventricular contractions, and the VT degenerated into VF in ∼ 30 s. ECG evidence of ischemia was infrequent and no different from those that survived. Baseline hemodynamics were no different among groups, but LV end-diastolic pressure during sympathetic activation was higher at the time of SCD (37 ± 4 vs. 26 ± 4 mmHg, P < 0.05) and the ECG demonstrated QT shortening (155 ± 4 vs. 173 ± 5 ms, P < 0.05). The week before SCD, both parameters were no different from survivors. These data indicate that there are no differences in the degree of sympathetic activation or hemodynamic stress when VT/VF develops in swine with hibernating myocardium. The transiently elevated LV end-diastolic pressure and QT shortening preceding VT/VF raises the possibility that electrocardiographically silent subendocardial ischemia and/or mechanoelectrical feedback serve as a trigger for the development of SCD in chronic ischemic heart disease.

  16. Three-dimensional assessment of postural tremor during goal-directed aiming.

    PubMed

    Kelleran, K J; Morrison, S; Russell, D M

    2016-12-01

    The performance of fine motor tasks which require a degree of precision can be negatively affected by physiological tremor. This study examined the effect of different aiming positions on anterior-posterior (AP), medial-lateral (ML) and vertical (VT) postural tremor. Participants were required to aim a mock handgun at a target located in front of them at eye level. Changes in AP, ML and VT tremor from the forearm and gun barrel were assessed as a function of limb (i.e., whether one or both arms were used) and upper arm position (elbow bent or extended). Tremor was recorded using triaxial accelerometers. Results showed that, across all tasks, the ML and VT tremor for any point was characterized by two frequency peaks (between 1-4 and 8-12 Hz) with amplitude increasing from proximal (forearm) to distal (gun barrel). Interestingly, irrespective of the posture adopted, ML accelerations were of greater amplitude than VT oscillations. AP oscillations were markedly smaller compared to VT and ML tremor, did not display consistent frequency peaks, and were not altered by the arm conditions. Altering the aiming posture resulted in changes in VT and ML tremor amplitude, with oscillations being greater when using a single arm as compared to when two arms were used together. Similarly, tremor amplitude was reduced when the task was performed with the elbow bent compared to the straight arm condition. Overall, these results highlight that ML oscillations make as significant a contribution to the overall tremor dynamics as those observed in the VT direction. However, the origin of ML tremor is not simply the product of voluntary adjustments to maintain aim on the target, but also exhibits features similar to the neural generated 8-12-Hz tremor seen under postural conditions.

  17. Comparative proteomic analysis of two wasps venom, Vespa tropica and Vespa affinis.

    PubMed

    Rungsa, Prapenpuksiri; Incamnoi, Paroonkorn; Sukprasert, Sophida; Uawonggul, Nunthawun; Klaynongsruang, Sompong; Daduang, Jureerut; Patramanon, Rina; Roytrakul, Sittiruk; Daduang, Sakda

    2016-09-01

    Vespid venom is composed of many bioactive compounds. The venom of the banded tiger wasp (Vespa affinis, or VA) and the great banded wasp (Vespa tropica, or VT)-which are locally found in the northeastern part of Thailand and are well known for their life-threatening venom potency-were comparatively studied in terms of potency, composition and biological activity. Clinical studies that included word-of-mouth information shared by traditional healers in local areas noted that the venom of VT is more potent than that of VA. Our previous study showed that the venom of VA is lower in potency (PD50 = 12.5 μg/g body weight) than that of VT (PD50 = 3 μg/g body weight). Analysis with the PAGE technique showed that these two venoms showed similar patterns of active proteins. Most protein spots were basic proteins at an isoelectric point (pI) ranging from 5 to 10, with molecular weights between 27 and 50 kDa. These spots were identified as hyaluronidase, phospholipase, antigen 5, dipeptidyl peptidase and albumin-like protein. The proportion of hyaluronidase was 2.5 times higher in VT than in VA. VT also showed higher hyaluronidase, phospholipase and dipeptidyl peptidase activities, suggesting that these components made VT venom more potent than VA venom. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Increased apical Na+ permeability in cystic fibrosis is supported by a quantitative model of epithelial ion transport

    PubMed Central

    O’Donoghue, Donal L; Dua, Vivek; Moss, Guy W J; Vergani, Paola

    2013-01-01

    Cystic fibrosis (CF) is caused by mutations in the cystic fibrosis transmembrane conductance regulator (CFTR) gene, which encodes an anion channel. In the human lung CFTR loss causes abnormal ion transport across airway epithelial cells. As a result CF individuals produce thick mucus, suffer persistent bacterial infections and have a much reduced life expectancy. Trans-epithelial potential difference (Vt) measurements are routinely carried out on nasal epithelia of CF patients in the clinic. CF epithelia exhibit a hyperpolarised basal Vt and a larger Vt change in response to amiloride (a blocker of the epithelial Na+ channel, ENaC). Are these altered bioelectric properties solely a result of electrical coupling between the ENaC and CFTR currents, or are they due to an increased ENaC permeability associated with CFTR loss? To examine these issues we have developed a quantitative mathematical model of human nasal epithelial ion transport. We find that while the loss of CFTR permeability hyperpolarises Vt and also increases amiloride-sensitive Vt, these effects are too small to account for the magnitude of change observed in CF epithelia. Instead, a parallel increase in ENaC permeability is required to adequately fit observed experimental data. Our study provides quantitative predictions for the complex relationships between ionic permeabilities and nasal Vt, giving insights into the physiology of CF disease that have important implications for CF therapy. PMID:23732645

  19. Effects of Ving Tsun Chinese martial art training on musculoskeletal health, balance performance, and self-efficacy in community-dwelling older adults.

    PubMed

    Lip, Ryan W T; Fong, Shirley S M; Ng, Shamay S M; Liu, Karen P Y; Guo, X

    2015-03-01

    [Purpose] The aim of this study was to investigate the effects of Ving Tsun (VT) Chinese martial art training on radial bone strength, upper- and lower-limb muscular strength, shoulder joint mobility, balance performance, and self-efficacy in elderly participants. [Subjects and Methods] Twelve seniors voluntarily joined the VT training group, and twenty-seven seniors voluntarily joined the control group. The VT group received VT training for three months, while the control group received no training. The bone strength of the distal radius was assessed using an ultrasound bone sonometer. Muscular strength in the limbs was evaluated using a Jamar handgrip dynamometer and the five times sit-to-stand test. Shoulder joint mobility was examined using a goniometer. Balance performance and self-efficacy were evaluated using the Berg Balance Scale and the Chinese version of the Activities-specific Balance Confidence Scale, respectively. [Results] The results revealed a nonsignificant group-by-time interaction effect, group effect, and time effect for all outcome variables. However, general trends of maintenance or improvement in all outcome parameters were observed to a greater extent in the VT group than in the control group. [Conclusion] VT training might be a potential fall-prevention exercise that can be used to maintain general physique, balance, and confidence in the elderly population. A further randomized controlled trial is needed to confirm this postulation.

  20. Effects of Ving Tsun Chinese martial art training on musculoskeletal health, balance performance, and self-efficacy in community-dwelling older adults

    PubMed Central

    Lip, Ryan W.T.; Fong, Shirley S.M.; Ng, Shamay S.M.; Liu, Karen P.Y.; Guo, X.

    2015-01-01

    [Purpose] The aim of this study was to investigate the effects of Ving Tsun (VT) Chinese martial art training on radial bone strength, upper- and lower-limb muscular strength, shoulder joint mobility, balance performance, and self-efficacy in elderly participants. [Subjects and Methods] Twelve seniors voluntarily joined the VT training group, and twenty-seven seniors voluntarily joined the control group. The VT group received VT training for three months, while the control group received no training. The bone strength of the distal radius was assessed using an ultrasound bone sonometer. Muscular strength in the limbs was evaluated using a Jamar handgrip dynamometer and the five times sit-to-stand test. Shoulder joint mobility was examined using a goniometer. Balance performance and self-efficacy were evaluated using the Berg Balance Scale and the Chinese version of the Activities-specific Balance Confidence Scale, respectively. [Results] The results revealed a nonsignificant group-by-time interaction effect, group effect, and time effect for all outcome variables. However, general trends of maintenance or improvement in all outcome parameters were observed to a greater extent in the VT group than in the control group. [Conclusion] VT training might be a potential fall-prevention exercise that can be used to maintain general physique, balance, and confidence in the elderly population. A further randomized controlled trial is needed to confirm this postulation. PMID:25931704

  1. Central and peripheral effects of the non-neural substances on respiration before and after vagotomy.

    PubMed

    Sahin, G; Oruç, T; Simşek, G; Güner, I

    1997-08-01

    The central effects of capsaicin, veratrine, histamine and bradykinin were studied by injecting them directly into the oerebrospinal fluid and their peripheral effects were examined by injecting into femoral vein. Our experiments were performed in Na-pentobarbital-anaesthetized dogs. Tidal volume (VT), respiratory frequency (f/min), systemic arterial pressure (BP) were recorded. A significant increase in f, and an initial apnea or hypoventilation followed by a significant increase in VT were observed with central and peripheral capsaicin. Vagotomy removed the peripheral VT response, but not the central one. While central capsaicin administration increased BP, peripheral administration decreased. After vagotomy, a significant increase was observed in BP for both administrations. Respiratory responses to central and peripheral administrations of veratrine were similar to those of capsaicin. Significant increases were observed in f and VT of the intact group in response to central and peripheral administration of histamine. Response to peripheral administration disappeared after vagotomy. While central and peripheral bradykinin increased VT significantly, there was no significant change in f. Vagotomy only removed the increase in VT in response to peripheral administration. In conclusion, respiratory responses to central administration of capsaicin and veratrine are due to direct effects of these substances on respiratory neurons. In peripheral administration, disappearance of the responses after vagotomy indicate that the responses are brought about by stimulation of the lung receptors.

  2. Unraveling torsional bath interactions with the CO stretching state in methanol

    NASA Astrophysics Data System (ADS)

    Pearson, John C.; Daly, Adam M.; Lees, Ronald M.

    2015-12-01

    Quantum mechanical models describing the effects of a C3 internal rotor have been successful in modeling all the torsional manifolds of isolated vibrational states. However, modeling the coupling between nearly degenerate small amplitude vibrations in the C3 internal rotation case remains far from satisfactory and a variety of practical and fundamental questions persist on basis sets, the relative importance of effects and how the problem should be approached. The ν8 C-O stretching state of methanol has been well studied with infrared techniques and has the potential to serve as an experimental reference data set for the development of models for the coupled large and small amplitude motion case. A combined infrared-microwave study of the lowest K A-states of vt = 3, vt = 4 and ν8 has been performed to understand the nature of the interactions between ν8 the excited torsional states. The interaction between vt = 4 and ν8 at K = 0+ has been confirmed to be Fermi type with magnitude of 2.5 cm-1. Additionally, the fundamental a-symmetry and b-symmetry Coriolis interactions between vt = 3 and ν8 have been estimated to be 8900 MHz and -360 MHz, respectively. The magnitude of these interactions suggests that modeling the ν8 state, the vt = 3 state, and the vt = 4 states will have to carefully account for these interactions.

  3. Lung and chest wall impedances in the dog in normal range of breathing: effects of pulmonary edema.

    PubMed

    Barnas, G M; Stamenović, D; Lutchen, K R

    1992-09-01

    We evaluated the effect of pulmonary edema on the frequency (f) and tidal volume (VT) dependences of respiratory system mechanical properties in the normal ranges of breathing. We measured resistance and elastance of the lungs (RL and EL) and chest wall of four anesthetized-paralyzed dogs during sinusoidal volume oscillations at the trachea (50-300 ml, 0.2-2 Hz), delivered at a constant mean airway pressure. Measurements were made before and after severe pulmonary edema was produced by injection of 0.06 ml/kg oleic acid into the right atrium. Chest wall properties were not changed by the injection. Before oleic acid, EL increased slightly with increasing f in each dog but was independent of VT. RL decreased slightly and was independent of VT from 0.2 to 0.4 Hz, but above 0.4 Hz it tended to increase with increasing flow, presumably due to the airway contribution. After oleic acid injection, EL and RL increased greatly. Large negative dependences of EL on VT and of RL on f were also evident, so that EL and RL after oleic acid changed two- and fivefold, respectively, within the ranges of f and VT studied. We conclude that severe pulmonary edema changes lung properties so as to make behavior VT dependent (i.e., nonlinear) and very frequency dependent in the normal range of breathing.

  4. Apolipoprotein A-IV interacts synergistically with melanocortins to reduce food intake.

    PubMed

    Gotoh, Koro; Liu, Min; Benoit, Stephen C; Clegg, Deborah J; Davidson, W Sean; D'Alessio, David; Seeley, Randy J; Tso, Patrick; Woods, Stephen C

    2006-01-01

    Apolipoprotein (apo) A-IV is an anorexigenic gastrointestinal peptide that is also synthesized in the hypothalamus. The goal of these experiments was to determine whether apo A-IV interacts with the central melanocortin (MC) system in the control of feeding. The third ventricular (i3vt) administration of a subthreshold dose of apo A-IV (0.5 microg) potentiated i3vt MC-induced (metallothionein-II, 0.03 nmol) suppression of 30-min feeding in Long-Evans rats. A subthreshold dose of the MC antagonist (SHU9119, 0.1 nmol, i3vt) completely attenuated the anorectic effect of i3vt apo A-IV (1.5 microg). The i3vt apo A-IV significantly elevated the expression of c-Fos in neurons of the paraventricular nucleus of the hypothalamus, but not in the arcuate nucleus or median eminence. In addition, c-Fos expression was not colocalized with proopiomelanocortin-positive neurons. These data support a synergistic interaction between apo A-IV and melanocortins that reduces food intake by acting downstream of the arcuate.

  5. Darwin's wind hypothesis: does it work for plant dispersal in fragmented habitats?

    PubMed

    Riba, Miquel; Mayol, Maria; Giles, Barbara E; Ronce, Ophélie; Imbert, Eric; van der Velde, Marco; Chauvet, Stéphanie; Ericson, Lars; Bijlsma, R; Vosman, Ben; Smulders, M J M; Olivieri, Isabelle

    2009-08-01

    Using the wind-dispersed plant Mycelis muralis, we examined how landscape fragmentation affects variation in seed traits contributing to dispersal. Inverse terminal velocity (Vt(-1)) of field-collected achenes was used as a proxy for individual seed dispersal ability. We related this measure to different metrics of landscape connectivity, at two spatial scales: in a detailed analysis of eight landscapes in Spain and along a latitudinal gradient using 29 landscapes across three European regions. In the highly patchy Spanish landscapes, seed Vt(-1)increased significantly with increasing connectivity. A common garden experiment suggested that differences in Vt(-1) may be in part genetically based. The Vt(-1) was also found to increase with landscape occupancy, a coarser measure of connectivity, on a much broader (European) scale. Finally, Vt(-1)was found to increase along a south-north latitudinal gradient. Our results for M. muralis are consistent with 'Darwin's wind dispersal hypothesis' that high cost of dispersal may select for lower dispersal ability in fragmented landscapes, as well as with the 'leading edge hypothesis' that most recently colonized populations harbour more dispersive phenotypes.

  6. Simulation of InGaAs subchannel DG-HEMTs for analogue/RF applications

    NASA Astrophysics Data System (ADS)

    Saravana Kumar, R.; Mohanbabu, A.; Mohankumar, N.; Godwin Raj, D.

    2018-03-01

    The paper reports on the influence of a barrier thickness and gate length on the various device parameters of double gate high electron mobility transistors (DG-HEMTs). The DC and RF performance of the device have been studied by varying the barrier thickness from 1 to 5 nm and gate length from 10 to 150 nm, respectively. As the gate length is reduced below 50 nm regime, the barrier thickness plays an important role in device performance. Scaling the gate length leads to higher transconductance and high frequency operations with the expense of poor short channel effects. The authors claim that the 30-nm gate length, mole fractions tuned In0.53Ga0.47As/In0.7Ga0.3As/In0.53Ga0.47As subchannel DG-HEMT with optimised device structure of 2 nm In0.48Al0.52As barrier layer show a peak gm of 3.09 mS/µm, VT of 0.29 V, ION/IOFF ratio of 2.24 × 105, subthreshold slope 73 mV/decade and drain induced barrier lowering 68 mV/V with fT and fmax of 776 and 905 GHz at Vds = 0.5 V is achieved. These superior performances are achieved by using double-gate architecture with reduced gate to channel distance.

  7. Ventricular Tachycardia or not? An Unexpected Reason of Wide QRS Complex Tachycardia in a Young Healthy Man: Sodium Bicarbonate.

    PubMed

    Eyuboglu, Mehmet

    2016-10-01

    Ventricular tachycardia (VT) is life-threatening subgroup of wide QRS complex tachycardia (WCT). VT is usually associated with structural heart diseases, but it can occur in the absence of any cardiovascular diseases. Adverse cardiac effect of sodium bicarbonate in healthy subjects is not well described. A 30-year-old healthy man with excessive intake of sodium bicarbonate-related VT is presented. He was using sodium bicarbonate during last 2 months to lose weight. He has no risk factors and any cardiovascular or systemic diseases. After intravenous administration of amiodarone, tachycardia ended and his rhythm converted to sinus rhythm with normal electrocardiogram. Patient is asymptomatic, and no VT was observed without any medications at 1 year of follow-up.

  8. Analytical model for the threshold voltage of III-V nanowire transistors including quantum effects

    NASA Astrophysics Data System (ADS)

    Marin, E. G.; Ruiz, F. G.; Tienda-Luna, I. M.; Godoy, A.; Gámiz, F.

    2014-02-01

    In this work we propose an analytical model for the threshold voltage (VT) of III-V cylindrical nanowires, that takes into consideration the two dimensional quantum confinement of the carriers, the Fermi-Dirac statistics, the wave-function penetration into the gate insulator and the non-parabolicity of the conduction band structure. A simple expression for VT is obtained assuming some suitable approximations. The model results are compared to those of a 2D self consistent Schrödinger-Poisson solver, demonstrating a good fit for different III-V materials, insulator thicknesses and nanowire sizes with diameter down to 5 nm. The VT dependence on the confinement effective mass is discussed. The different contributions to VT are analyzed showing significant variations among different III-V materials.

  9. Length of the solar cycle influence on the relationship NAO-Northern Hemisphere Temperature

    NASA Astrophysics Data System (ADS)

    de La Torre, L.; Gimeno, L.; Tesouro, M.; Añel, J. A.; Nieto, R.; Ribera, P.; García, R.; Hernández, E.

    2003-04-01

    The influence of the length of the solar cycle on the relationship North Atlantic Oscillation (NAO)-Northern Hemisphere Temperature (NHT) is investigated. The results suggest that this relationship is different according to the length of the solar cycle. When the sunspot cycle is 10 or 11 years long, wintertime NAO and NHT are positively correlated, being the signal more intense during 11 years period, but when the sunspot cycle is longer (12 years) correlations between wintertime NAO and NHT are not significant. In fact there are significant negative correlations between wintertime NAO and spring NHT, with predictive potential.

  10. Adaptive Circuits for the 0.5-V Nanoscale CMOS Era

    NASA Astrophysics Data System (ADS)

    Itoh, Kiyoo; Yamaoka, Masanao; Oshima, Takashi

    The minimum operating voltage, Vmin, of nanoscale CMOS LSIs is investigated to breach the 1-V wall that we are facing in the 65-nm device generation, and open the door to the below 0.5-V era. A new method using speed variation is proposed to evaluate Vmin. It shows that Vmin is very sensitive to the lowest necessary threshold voltage, Vt0, of MOSFETs and to threshold-voltage variations, ΔVt, which become more significant with device scaling. There is thus a need for low-Vt0 circuits and ΔVt-immune MOSFETs to reduce Vmin. For memory-rich LSIs, the SRAM block is particularly problematic because it has the highest Vmin. Various techniques are thus proposed to reduce the Vmin: using RAM repair, shortening the data line, up-sizing, and using more relaxed MOSFET scaling. To effectively reduce Vmin of other circuit blocks, dual-Vt0 and dual-VDD circuits using gate-source reverse biasing, temporary activation, and series connection of another small low-Vt0 MOSFET are proposed. They are dynamic logic circuits enabling the power-delay product of the conventional static CMOS inverter to be reduced to 0.09 at a 0.2-V supply, and a DRAM dynamic sense amplifier and power switches operable at below 0.5V. In addition, a fully-depleted structure (FD-SOI) and fin-type structure (FinFET) for Vt-immune MOSFETs are discussed in terms of their low-voltage potential and challenges. As a result, the height up-scalable FinFETs turns out to be quite effective to reduce Vmin to less than 0.5V, if combined with the low-Vt0 circuits. For mixed-signal LSIs, investigation of low-voltage potential of analog circuits, especially for comparators and operational amplifiers, reveals that simple inverter op-amps, in which the low gain and nonlinearity are compensated for by digitally assisted analog designs, are crucial to 0.5-V operations. Finally, it is emphasized that the development of relevant devices and fabrication processes is the key to the achievement of 0.5-V nanoscale LSIs.

  11. Uterine length and fertility outcomes: a cohort study in the IVF population.

    PubMed

    Hawkins, L K; Correia, K F; Srouji, S S; Hornstein, M D; Missmer, S A

    2013-11-01

    What is the relationship between pre-cycle uterine length and IVF outcome (chemical pregnancy, clinical pregnancy, spontaneous abortion and live birth)? Women at extremes of uterine length (<7.0 or >9.0 cm) were less likely to achieve live birth and women with uterine lengths <6.0 cm were also more likely to experience spontaneous abortion. A prospective study of 807 women published in 2000 found that implantation and clinical pregnancy rates were highest in women with uterine lengths between 7.0 and 9.0 cm, though the difference was not significant. The relationship between pre-cycle uterine length and live birth has not been evaluated. A retrospective cohort study of all cycles performed after uterine length measurement at an academic hospital IVF clinic from 2001 to 2012. A total of 8981 fresh cycles were performed in 5120 adult women with normal uterine anatomy. Women with uterine anomalies (unicornuate, bicornuate, septate or uterus exposed to diethylstilbestrol) were excluded and women with fibroids were identified for subanalysis. Uterine length was measured by uterine sounding. Cycles were divided by uterine length into groups: <6.0 cm (very short, n = 76), 6.0-6.9 cm (short, n = 2014), 7.0-7.9 cm (referent, n = 4984), 8.0-8.9 cm (long, n = 1664) and ≥9 cm (very long, n = 243). Multivariate logistic regression (first-cycle analyses) and generalized estimating equations (all-cycle analyses) were adjusted for age, fibroids and ART treatment (assisted hatching, intracytoplasmic sperm injection) to generate relative risk (RR) of cycle outcomes by uterine length. Median uterine length in the IVF population was 7.0 cm (interquartile range 7.0-7.8) and was positively associated with BMI (P < 0.001) and fibroids (P = 0.02). Compared with the referent group, women with uterine lengths <6.0 cm were half as likely to achieve live birth (RR: 0.53; 95% confidence interval (CI): 0.35-0.81) and women with lengths of 6.0-6.9 cm were also less likely (RR: 0.91; CI: 0.85-0.98). Cubic regression spline identified a significant inverse U-shaped association whereby women with uterine lengths <7.0 or >9.0 cm were less likely to achieve live birth. Women with lengths <6.0 cm were also more likely to experience spontaneous abortion (RR: 2.16; CI: 1.23-3.78). Results remained consistent when excluding women with a uterine factor diagnosis (n = 8823), when limiting to the first cycle at our institution (n = 5120) and when further restricting to first-ever cycles (n = 3941). Optimal assessment of uterine length by ultrasound was not feasible due to time and cost limitations, though uterine sounding is a clinically relevant measurement allowing for results with practical implications. Findings from our predominantly Caucasian clinic population may not be generalizable to infertile populations with different ethnic compositions. Reproducibility of results would solidify findings and inform patient counseling in women undergoing IVF. No funding was sought for this investigation. MD declares relationships with UpToDate (royalties) and WINFertlity (consultant).

  12. 1D-¹H-nuclear magnetic resonance metabolomics reveals age-related changes in metabolites associated with experimental venous thrombosis.

    PubMed

    Obi, Andrea T; Stringer, Kathleen A; Diaz, Jose A; Finkel, Michael A; Farris, Diana M; Yeomans, Larisa; Wakefield, Thomas; Myers, Daniel D

    2016-04-01

    Age is a significant risk factor for the development of venous thrombosis (VT), but the mechanism(s) that underlie this risk remain(s) undefined and poorly understood. Aging is known to adversely influence inflammation and affect metabolism. Untargeted metabolomics permits an agnostic assessment of the physiological landscape and lends insight into the mechanistic underpinnings of clinical phenotypes. The objective of this exploratory study was to test the feasibility of a metabolomics approach for identifying potential metabolic mechanisms of age-related VT. We subjected whole blood samples collected from young and old nonthrombosed controls and VT mice 2 days after thrombus induction using the electrolytic inferior vena cava, to a methanol:chloroform extraction and assayed the resulting aqueous fractions using 1D-(1)H- nuclear magnetic resonance. Normalized mouse metabolite data were compared across groups using analysis of variance (ANOVA) with Holm-Sidak post-testing. In addition, associations between metabolite concentrations and parameters of thrombosis such as thrombus and vein wall weights, and markers of inflammation, vein wall P- and E-selectin levels, were assessed using linear regression. The relatedness of the found significant metabolites was visually assessed using a bioinformatics tool, Metscape, which generates compound-reaction-enzyme-gene networks to aid in the interpretation of metabolomics data. Old mice with VT had a greater mean vein wall weight compared with young mice with VT (P < .05). Clot weight differences between old and young mice followed the same trend as vein wall weight (0.011 ± 0.04 g vs 0.008 ± 0.003 g; P = not significant). Glutamine (ANOVA, P < .01), proline (ANOVA, P < .01), and phenylalanine (ANOVA, P < .05) levels were increased in old VT mice compared with age-matched controls and young VT mice. Betaine and/or trimethylamine N-oxide levels were increased in aged mice compared with young animals. Vein wall weight was strongly associated with glutamine (P < .05), and phenylalanine (P < .01) concentrations and there was a trend toward an association with proline (P = .09) concentration. Vein wall P-selectin, but not E-selectin levels, were increased in old VT mice and were associated with the three found metabolites of age-related VT. Collectively, with the addition of glutamate, these metabolites form a single compound-reaction-enzyme-gene network that was generated by Metscape. We used 1D-(1)H-nuclear magnetic resonance-metabolite profiling to identify, for the first time, in an experimental model, three potential metabolites, glutamine, phenylalanine, and proline, associated with age-related VT. These metabolites are metabolically related and their levels are associated with vein wall weight and P-selectin concentrations. In aggregate, these findings provide a "roadmap" of pathways that could be interrogated in future studies, which could include provocation of the glutamine, phenylalanine, and proline pathways in the vein wall. This study introduces metabolomics as a new approach to furthering knowledge about the mechanisms of age-related VT. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  13. Accreditation status of U.S. military graduate medical education programs.

    PubMed

    De Lorenzo, Robert A

    2008-07-01

    Military graduate medical education (GME) comprises a substantial fraction of U.S. physician training capacity. The wars in Iraq and Afghanistan have placed substantial stress on military medicine, and lay and professional press accounts have raised awareness of the effects on military GME. To date, however, objective data on military GME quality remains sparse. Determine the accreditation status of U.S. military GME programs. Additionally, military GME program data will be compared to national (U.S.) accreditation lengths. Retrospective review of Accreditation Council for Graduate Medical Education (ACGME) data. All military-sponsored core programs in specialties with at least three residencies were included. Military-affiliated but civilian-sponsored programs were excluded. The current and past cycle data were used for the study. For each specialty, the current mean accreditation length and the net change in cycle was calculated. National mean accreditation lengths by specialty for 2005 to 2006 were obtained from the ACGME. Comparison between the overall mean national and military accreditation lengths was performed with a z test. All other comparisons employed descriptive statistics. Ninety-nine military programs in 15 specialties were included in the analysis. During the study period, 1 program was newly accredited, and 6 programs had accreditation withdrawn or were closed. The mean accreditation length of the military programs was 4.0 years. The overall national mean for the same specialties is 3.5 years (p < 0.01). In previous cycles, 68% of programs had accreditation of 4 years or longer, compared to 70% in the current cycle, while 13% had accreditation of 2 years or less in the previous cycle compared to 14% in the current cycle. Ten (68%) of the military specialties had mean accreditation lengths greater than the national average, while 5 (33%) were below it. Ten (68%) specialties had stable or improving cycle lengths when compared to previous cycles. Military GME accreditation cycle lengths are, overall, longer than national averages. Trends show many military programs are experiencing either stable or slightly lengthening accreditation compared to previous cycles. A few specialties show a declining trend. There has been a modest 5% decline in the number of military core residency programs since 2000.

  14. 33 CFR 157.138 - Crude Oil Washing Operations and Equipment Manual.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Revolutions, number of cycles, and length of cycles of each COW machine. (iii) Pressure and flow of the... COW machines. (ii) Revolutions, number of cycles, and length of cycles of each COW machine. (iii... § 157.140. (10) The volume of water used for water rinsing recorded during COW operations when passing...

  15. 33 CFR 157.138 - Crude Oil Washing Operations and Equipment Manual.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Revolutions, number of cycles, and length of cycles of each COW machine. (iii) Pressure and flow of the... COW machines. (ii) Revolutions, number of cycles, and length of cycles of each COW machine. (iii... § 157.140. (10) The volume of water used for water rinsing recorded during COW operations when passing...

  16. 33 CFR 157.138 - Crude Oil Washing Operations and Equipment Manual.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Revolutions, number of cycles, and length of cycles of each COW machine. (iii) Pressure and flow of the... COW machines. (ii) Revolutions, number of cycles, and length of cycles of each COW machine. (iii... § 157.140. (10) The volume of water used for water rinsing recorded during COW operations when passing...

  17. Whole-Genome Characterization and Strain Comparison of VT2f-Producing Escherichia coli Causing Hemolytic Uremic Syndrome

    PubMed Central

    Michelacci, Valeria; Bondì, Roslen; Gigliucci, Federica; Franz, Eelco; Badouei, Mahdi Askari; Schlager, Sabine; Minelli, Fabio; Tozzoli, Rosangela; Caprioli, Alfredo; Morabito, Stefano

    2016-01-01

    Verotoxigenic Escherichia coli infections in humans cause disease ranging from uncomplicated intestinal illnesses to bloody diarrhea and systemic sequelae, such as hemolytic uremic syndrome (HUS). Previous research indicated that pigeons may be a reservoir for a population of verotoxigenic E. coli producing the VT2f variant. We used whole-genome sequencing to characterize a set of VT2f-producing E. coli strains from human patients with diarrhea or HUS and from healthy pigeons. We describe a phage conveying the vtx2f genes and provide evidence that the strains causing milder diarrheal disease may be transmitted to humans from pigeons. The strains causing HUS could derive from VT2f phage acquisition by E. coli strains with a virulence genes asset resembling that of typical HUS-associated verotoxigenic E. coli. PMID:27584691

  18. Kinetic modeling of the monoamine oxidase B radioligand [¹¹C]SL25.1188 in human brain with high-resolution positron emission tomography.

    PubMed

    Rusjan, Pablo M; Wilson, Alan A; Miler, Laura; Fan, Ian; Mizrahi, Romina; Houle, Sylvain; Vasdev, Neil; Meyer, Jeffrey H

    2014-05-01

    This article describes the kinetic modeling of [(11)C]SL25.1188 ([(S)-5-methoxymethyl-3-[6-(4,4,4-trifluorobutoxy)-benzo[d]isoxazol-3-yl]-oxazolidin-2-[(11)C]one]) binding to monoamine oxidase B (MAO-B) in the human brain using high-resolution positron emission tomography (PET). Seven healthy subjects underwent two separate 90- minute PET scans after an intravenous injection of [(11)C]SL25.1188. Complementary arterial blood sampling was acquired. Radioactivity was quickly eliminated from plasma with 80% of parent compound remaining at 90 minutes. Metabolites were more polar than the parent compound. Time-activity curves showed high brain uptake, early peak and washout rate consistent with known regional MAO-B concentration. A two-tissue compartment model (2-TCM) provided better fits to the data than a 1-TCM. Measurement of total distribution volume (VT) showed very good identifiability (based on coefficient of variation (COV)) for all regions of interest (ROIs) (COV(VT)<8%), low between-subject variability (∼20%), and quick temporal convergence (within 5% of final value at 45 minutes). Logan graphical method produces very good estimation of VT. Regional VT highly correlated with previous postmortem report of MAO-B level (r(2)= ≥ 0.9). Specific binding would account from 70% to 90% of VT. Hence, VT measurement of [(11)C]SL25.1(1)88 PET is an excellent estimation of MAO-B concentration.

  19. Musculoskeletal strength, balance performance, and self-efficacy in elderly ving tsun chinese martial art practitioners: implications for fall prevention.

    PubMed

    Fong, Shirley S M; Ng, Shamay S M; Liu, Karen P Y; Pang, Marco Y C; Lee, H W; Chung, Joanne W Y; Lam, Priscillia L; Guo, X

    2014-01-01

    Objectives. To (1) compare the bone strength, lower limb muscular strength, functional balance performance, and balance self-efficacy between Ving Tsun (VT) martial art practitioners and nonpractitioners and (2) identify the associations between lower limb muscular strength, functional balance performance, and balance self-efficacy among the VT-trained participants. Methods. Thirty-five VT practitioners (mean age ± SD = 62.7 ± 13.3 years) and 49 nonpractitioners (mean age ± SD = 65.9 ± 10.5 years) participated in the study. The bone strength of the distal radius, lower limb muscular strength, functional balance performance, and balance self-efficacy were assessed using an ultrasound bone sonometer, the five times sit-to-stand test (FTSTS), the Berg balance scale (BBS), and the Chinese version of the activities-specific balance confidence scale, respectively. A multivariate analysis of covariance was performed to compare all the outcome variables between the two groups. Results. Elderly VT practitioners had higher radial bone strength on the dominant side (P < 0.05), greater lower limb muscular strength (P = 0.001), better functional balance performance (P = 0.003), and greater balance confidence (P < 0.001) than the nonpractitioners. Additionally, only the FTSTS time revealed a significant association with the BBS score (r = -0.575,  P = 0.013). Conclusions. VT may be a suitable health-maintenance exercise for the elderly. Our findings may inspire the development of VT fall-prevention exercises for the community-dwelling healthy elderly.

  20. Management of ventricular tachycardia in the ablation era: results of the European Heart Rhythm Association Survey.

    PubMed

    Tilz, Roland Richard; Lenarczyk, Radoslaw; Scherr, Daniel; Haugaa, Kristina Herman; Iliodromitis, Konstantinos; Pürerfellner, Helmut; Kiliszek, Marek; Dagres, Nikolaos

    2018-01-01

    Patients with sustained ventricular tachycardia (VT) are at risk of sudden death. Treatment options for VT include antiarrhythmic drug therapy, insertion of an implantable cardioverter-defibrillator, and catheter ablation. Evidence on indications for VT ablation, timing, ablation strategies, and periprocedural management is sparse. The aim of this European Heart Rhythm Association (EHRA) survey was to evaluate clinical practice regarding management of VT among the European countries. An electronic questionnaire was sent to members of the EHRA Electrophysiology Research Network. Responses were received from 88 centres in 12 countries. The results have shown that management of VTs is very heterogeneous across the participating centres. Indications, periprocedural management, and ablation strategies vary substantially. This EP Wire survey has revealed that catheter ablation is the first-line therapy for the treatment of recurrent monomorphic stable VT in patients without structural heart disease as well as in patients with ischaemic cardiomyopathy and impaired left ventricular ejection fraction in the majority of centres. Furthermore, in patients with ischaemic cardiomyopathy and the first episode of monomorphic VT, most centres (62.0%) performed catheter ablation. On the contrary, in patients with non-ischaemic cardiomyopathy, amiodarone (41.4%) and catheter ablation (37.1%) are used in a very similar proportion. Ablation strategies, endpoints, and post-ablation antithrombotic management vary substantially among European centres. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  1. Comparative evaluation of hemodynamic and respiratory parameters during mechanical ventilation with two tidal volumes calculated by demi-span based height and measured height in normal lungs

    PubMed Central

    Seresht, L. Mousavi; Golparvar, Mohammad; Yaraghi, Ahmad

    2014-01-01

    Background: Appropriate determination of tidal volume (VT) is important for preventing ventilation induced lung injury. We compared hemodynamic and respiratory parameters in two conditions of receiving VTs calculated by using body weight (BW), which was estimated by measured height (HBW) or demi-span based body weight (DBW). Materials and Methods: This controlled-trial was conducted in St. Alzahra Hospital in 2009 on American Society of Anesthesiologists (ASA) I and II, 18-65-years-old patients. Standing height and weight were measured and then height was calculated using demi-span method. BW and VT were calculated with acute respiratory distress syndrome-net formula. Patients were randomized and then crossed to receive ventilation with both calculated VTs for 20 min. Hemodynamic and respiratory parameters were analyzed with SPSS version 20.0 using univariate and multivariate analyses. Results: Forty nine patients were studied. Demi-span based body weight and thus VT (DTV) were lower than Height based body weight and VT (HTV) (P = 0.028), in male patients (P = 0.005). Difference was observed in peak airway pressure (PAP) and airway resistance (AR) changes with higher PAP and AR at 20 min after receiving HTV compared with DTV. Conclusions: Estimated VT based on measured height is higher than that based on demi-span and this difference exists only in females, and this higher VT results higher airway pressures during mechanical ventilation. PMID:24627845

  2. Comparative evaluation of hemodynamic and respiratory parameters during mechanical ventilation with two tidal volumes calculated by demi-span based height and measured height in normal lungs.

    PubMed

    Seresht, L Mousavi; Golparvar, Mohammad; Yaraghi, Ahmad

    2014-01-01

    Appropriate determination of tidal volume (VT) is important for preventing ventilation induced lung injury. We compared hemodynamic and respiratory parameters in two conditions of receiving VTs calculated by using body weight (BW), which was estimated by measured height (HBW) or demi-span based body weight (DBW). This controlled-trial was conducted in St. Alzahra Hospital in 2009 on American Society of Anesthesiologists (ASA) I and II, 18-65-years-old patients. Standing height and weight were measured and then height was calculated using demi-span method. BW and VT were calculated with acute respiratory distress syndrome-net formula. Patients were randomized and then crossed to receive ventilation with both calculated VTs for 20 min. Hemodynamic and respiratory parameters were analyzed with SPSS version 20.0 using univariate and multivariate analyses. Forty nine patients were studied. Demi-span based body weight and thus VT (DTV) were lower than Height based body weight and VT (HTV) (P = 0.028), in male patients (P = 0.005). Difference was observed in peak airway pressure (PAP) and airway resistance (AR) changes with higher PAP and AR at 20 min after receiving HTV compared with DTV. Estimated VT based on measured height is higher than that based on demi-span and this difference exists only in females, and this higher VT results higher airway pressures during mechanical ventilation.

  3. Influence of Training Load and Altitude on HRV Fatigue Patterns in Elite Nordic Skiers.

    PubMed

    Schmitt, Laurent; Regnard, Jacques; Coulmy, Nicolas; Millet, Gregoire P

    2018-06-14

    We aimed to analyse the relationship between training load/intensity and different heart rate variability (HRV) fatigue patterns in 57 elite Nordic-skiers. 1063 HRV tests were performed during 5 years. R-R intervals were recorded in resting supine (SU) and standing (ST) positions. Heart rate, low (LF), high (HF) frequency powers of HRV were determined. Training volume, training load (TL, a.u.) according to ventilatory threshold 1 (VT1) and VT2 were measured in zones I≤VT1; VT1VT2, IV for strength. TL was performed at 81.6±3.5% in zone I, 0.9±0.9% in zone II, 5.0±3.6% in zone III, 11.6±6.3% in zone IV. 172 HRV tests matched a fatigue state and four HRV fatigue patterns (F) were statistically characterized as F(HF-LF-)SU_ST for 121 tests, F(LF+SULF-ST) for 18 tests, F(HF-SUHF+ST) for 26 tests and F(HF+SU) for 7 tests. The occurrence of fatigue states increased substantially with the part of altitude training time (r2=0.52, p<0.001). This study evidenced that there is no causal relationship between training load/intensity and HRV fatigue patterns. Four fatigue-shifted HRV patterns were sorted. Altitude training periods appeared critical as they are likely to increase the overreaching risks. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Alcohol responsiveness in laryngeal dystonia: A survey study

    PubMed Central

    Kirke, Diana N.; Frucht, Steven J.; Simonyan, Kristina

    2015-01-01

    Laryngeal dystonia (LD) is a task-specific focal dystonia of unknown pathophysiology affecting speech production. We examined the demographics of anecdotally reported alcohol use and its effects on LD symptoms using an online survey based on Research Electronic Data Capture (REDCap™) and National Spasmodic Dysphonia Association’s patient registry. From 641 participants, 531 were selected for data analysis, and 110 were excluded because of unconfirmed diagnosis. A total of 406 patients (76.5%) had LD and 125 (23.5%) had LD and voice tremor (LD/VT). The consumption of alcohol was reported by 374 LD (92.1%) and 109 LD/VT (87.2%) patients. Improvement of voice symptoms after alcohol ingestion was noted by 227 LD (55.9% of all patients) and 73 LD/VT (58.4%), which paralleled the improvement observed by patient’s family and/or friends in 214 LD (57.2%) and 69 LD/VT (63.3%) patients. The benefits lasted 1–3 hours in both groups with the maximum effect after 2 drinks in LD patients (p = 0.002), whereas LD/VT symptoms improved independent of the consumed amount (p = 0.48). Our data suggest that isolated dystonic symptoms, such as in LD, are responsive to alcohol intake and this responsiveness is not attributed to the presence of VT, which is known to have significant benefits from alcohol ingestion. Alcohol may modulate the pathophysiological mechanisms underlying abnormal neurotransmission of γ-aminobutyric acid (GABA) in dystonia and as such provide new avenues for novel therapeutic options in these patients. PMID:25929664

  5. Musculoskeletal Strength, Balance Performance, and Self-Efficacy in Elderly Ving Tsun Chinese Martial Art Practitioners: Implications for Fall Prevention

    PubMed Central

    Fong, Shirley S. M.; Ng, Shamay S. M.; Liu, Karen P. Y.; Pang, Marco Y. C.; Lee, H. W.; Chung, Joanne W. Y.; Lam, Priscillia L.; Guo, X.

    2014-01-01

    Objectives. To (1) compare the bone strength, lower limb muscular strength, functional balance performance, and balance self-efficacy between Ving Tsun (VT) martial art practitioners and nonpractitioners and (2) identify the associations between lower limb muscular strength, functional balance performance, and balance self-efficacy among the VT-trained participants. Methods. Thirty-five VT practitioners (mean age ± SD = 62.7 ± 13.3 years) and 49 nonpractitioners (mean age ± SD = 65.9 ± 10.5 years) participated in the study. The bone strength of the distal radius, lower limb muscular strength, functional balance performance, and balance self-efficacy were assessed using an ultrasound bone sonometer, the five times sit-to-stand test (FTSTS), the Berg balance scale (BBS), and the Chinese version of the activities-specific balance confidence scale, respectively. A multivariate analysis of covariance was performed to compare all the outcome variables between the two groups. Results. Elderly VT practitioners had higher radial bone strength on the dominant side (P < 0.05), greater lower limb muscular strength (P = 0.001), better functional balance performance (P = 0.003), and greater balance confidence (P < 0.001) than the nonpractitioners. Additionally, only the FTSTS time revealed a significant association with the BBS score (r = −0.575,  P = 0.013). Conclusions. VT may be a suitable health-maintenance exercise for the elderly. Our findings may inspire the development of VT fall-prevention exercises for the community-dwelling healthy elderly. PMID:25530782

  6. Prefrontal oxygenation and the acoustic startle eyeblink response during exercise: A test of the dual-mode model.

    PubMed

    Tempest, Gavin D; Parfitt, Gaynor

    2017-07-01

    The interplay between the prefrontal cortex and amygdala is proposed to explain the regulation of affective responses (pleasure/displeasure) during exercise as outlined in the dual-mode model. However, due to methodological limitations the dual-mode model has not been fully tested. In this study, prefrontal oxygenation (using near-infrared spectroscopy) and amygdala activity (reflected by eyeblink amplitude using acoustic startle methodology) were recorded during exercise standardized to metabolic processes: 80% of ventilatory threshold (below VT), at the VT, and at the respiratory compensation point (RCP). Self-reported tolerance of the intensity of exercise was assessed prior to, and affective responses recorded during exercise. The results revealed that, as the intensity of exercise became more challenging (from below VT to RCP), prefrontal oxygenation was larger and eyeblink amplitude and affective responses were reduced. Below VT and at VT, larger prefrontal oxygenation was associated with larger eyeblink amplitude. At the RCP, prefrontal oxygenation was greater in the left than right hemisphere, and eyeblink amplitude explained significant variance in affective responses (with prefrontal oxygenation) and self-reported tolerance. These findings highlight the role of the prefrontal cortex and potentially the amygdala in the regulation of affective (particularly negative) responses during exercise at physiologically challenging intensities (above VT). In addition, a psychophysiological basis of self-reported tolerance is indicated. This study provides some support of the dual-mode model and insight into the neural basis of affective responses during exercise. © 2017 Society for Psychophysiological Research.

  7. Whole-Body High-Intensity Interval Training Induce Similar Cardiorespiratory Adaptations Compared With Traditional High-Intensity Interval Training and Moderate-Intensity Continuous Training in Healthy Men.

    PubMed

    Schaun, Gustavo Z; Pinto, Stephanie S; Silva, Mariana R; Dolinski, Davi B; Alberton, Cristine L

    2018-05-07

    Schaun, GZ, Pinto, SS, Silva, MR, Dolinski, DB, and Alberton, CL. Sixteen weeks of whole-body high-intensity interval training induce similar cardiorespiratory responses compared with traditional high-intensity interval training and moderate-intensity continuous training in healthy men. J Strength Cond Res XX(X): 000-000, 2018-Low-volume high-intensity interval training (HIIT) protocols that use the body weight as resistance could be an interesting and inexpensive alternative to traditional ergometer-based high-intensity interval training (HIIT-T) and moderate-intensity continuous training (MICT). Therefore, our aim was to compare the effects of 16 weeks of whole-body HIIT (HIIT-WB), HIIT-T, and MICT on maximal oxygen uptake (V[Combining Dot Above]O2max), second ventilatory threshold (VT2), and running economy (RE) outcomes. Fifty-five healthy men (23.7 ± 0.7 years, 1.79 ± 0.01 m, 78.5 ± 1.7 kg) were randomized into 3 training groups (HIIT-T = 17; HIIT-WB = 19; MICT = 19) for 16 weeks (3× per week). The HIIT-T group performed eight 20-second bouts at 130% of the velocity associated to V[Combining Dot Above]O2max (vV[Combining Dot Above]O2max) interspersed by 10-second passive recovery on a treadmill, whereas HIIT-WB group performed the same protocol but used calisthenics exercises at an all-out intensity instead of treadmill running. Finally, MICT group exercised for 30 minutes at 90-95% of the heart rate (HR) associated to VT2. After the intervention, all groups improved V[Combining Dot Above]O2max, vV[Combining Dot Above]O2max, time to exhaustion (Tmax), VT2, velocity associated with VT2 (vVT2), and time to reach VT2 (tVT2) significantly (p < 0.05). Moreover, Tmax, vVT2, and tVT2 were greater after HIIT-T compared with HIIT-WB (p < 0.05), whereas oxygen uptake increased and HR decreased during the RE test in all groups (p < 0.05). Our results demonstrate that HIIT-WB can be as effective as traditional HIIT while also being time-efficient compared with MICT to improve health-related outcomes after 16 weeks of training. However, HIIT-T and MICT seem preferable to enhance performance-related outcomes compared with HIIT-WB.

  8. Role of bronchodilation and pattern of breathing in increasing tidal expiratory flow with progressive induced hypercapnia in chronic obstructive pulmonary disease.

    PubMed

    Finucane, Kevin E; Singh, Bhajan

    2018-01-01

    Hypercapnia (HC) in vitro relaxes airway smooth muscle; in vivo, it increases respiratory effort, tidal expiratory flows (V̇ exp ), and, by decreasing inspiratory duration (Ti), increases elastic recoil pressure (Pel) via lung viscoelasticity; however, its effect on airway resistance is uncertain. We examined the contributions of bronchodilation, Ti, and expiratory effort to increasing V̇ exp with progressive HC in 10 subjects with chronic obstructive pulmonary disease (COPD): mean forced expiratory volume in 1 s (FEV 1 ) 53% predicted. Lung volumes (Vl), V̇ exp , esophageal pressure (Pes), Ti, and end-tidal Pco 2 ([Formula: see text]) were measured during six tidal breaths followed by an inspiratory capacity (IC), breathing air, and at three levels of HC. V̇ exp and V̇ with submaximal forced vital capacities breathing air (V̇ sFVC ) were compared. Pulmonary resistance ( Rl) was measured from the Pes-V̇ relationship. V̇ exp and Pes at end-expiratory lung volume (EELV) + 0.3 tidal volume [V̇ (0.3Vt) and Pes (0.3Vt) , respectively], Ti, and Rl correlated with [Formula: see text] ( P < 0.001 for all) and were independent of tiotropium. [Formula: see text], Ti, and Pes (0.3Vt) predicted the increasing V̇ (0.3Vt) /V̇ sFVC(0.3Vt) [multiple regression analysis (MRA): P = 0.001, 0.004, and 0.025, respectively]. At [Formula: see text] ≥ 50 Torr, V̇ (0.3Vt) /V̇ sFVC(0.3Vt) exceeded unity in 30 of 36 measurements and was predicted by [Formula: see text] and Pes (0.3Vt) (MRA: P = 0.02 and 0.025, respectively). Rl decreased at [Formula: see text] 45 Torr ( P < 0.05) and did not change with further HC. IC and Vl (0.3Vt) did not change with HC. We conclude that in COPD HC increases V̇ exp due to bronchodilation, increased Pel secondary to decreasing Ti, and increased expiratory effort, all promoting lung emptying and a stable EELV. NEW & NOTEWORTHY The response of airways to intrapulmonary hypercapnia (HC) is uncertain. In chronic obstructive pulmonary disease (COPD), progressive HC increases tidal expiratory flows by inducing bronchodilation and via an increased rate of inspiration and lung viscoelasticity, a probable increase in lung elastic recoil pressure, both changes increasing expiratory flows, promoting lung emptying and a stable end-expiratory volume. Bronchodilation with HC occurred despite optimal standard bronchodilator therapy, suggesting that in COPD further bronchodilation is possible.

  9. Influence of smoking and obesity on alveolar-arterial gas pressure differences and dead space ventilation at rest and peak exercise in healthy men and women.

    PubMed

    Gläser, Sven; Ittermann, Till; Koch, Beate; Schäper, Christoph; Felix, Stephan B; Völzke, Henry; Könemann, Raik; Ewert, Ralf; Hansen, James E

    2013-06-01

    Besides exercise intolerance, the assessment of ventilatory and perfusion adequacy allows additional insights in the disease pathophysiology in many cardiovascular or pulmonary diseases. Valid measurements of dead space/tidal volume ratios (VD/VT), arterial (a') - end-tidal (et) carbon dioxide (CO2) and oxygen (O2) pressure differences (p(a'-et)CO2) and (p(et-a')O2), and alveolar (A)-a' O2 pressure differences (p(A-a')O2) require using blood samples in addition to gas exchange analyses on a breath-by-breath-basis. Smoking and nutritional status are also important factors in defining disorders. Using a large healthy population we considered the impact of these factors to develop useful prediction equations. Incremental cycle exercise protocols were applied to apparently healthy volunteer adults who did not have structural heart disease or echocardiographic or lung function pathologies. Age, height, weight, and smoking were analysed for their influence on the target parameters in each gender. Reference values were determined by regression analyses. The final study sample consisted of 476 volunteers (190 female), aged 25-85 years. Smoking significantly influences p(A-a')O2 and p(a'-et)CO2 at rest and peak exercise, and VD/VT during exercise. Obesity influences upper limits of VD/VT, p(a'-et)CO2 and p(et-a')O2 at rest as well as p(A-a')O2 and p(et-a')O2 at exercise. Reference equations for never-smokers as well as for apparently healthy smokers considering influencing factors are given. Gender, age, height, weight, and smoking significantly influence gas exchange. Considering all of these factors this study provides a comprehensive set of reference equations derived from a large number of participants of a population-based study. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Impact of double-tiered subchondral support procedure with a polyaxial locking plate on the stability of distal radius fractures using fresh cadaveric forearms: Biomechanical and radiographic analyses.

    PubMed

    Tsutsui, Sadaaki; Kawasaki, Keikichi; Yamakoshi, Ken-Ichi; Uchiyama, Eiichi; Aoki, Mitsuhiro; Inagaki, Katsunori

    2016-09-01

    The present study compared the changes in biomechanical and radiographic properties under cyclic axial loadings between the 'double-tiered subchondral support' (DSS) group (wherein two rows of screws were used) and the 'non-DSS' (NDSS) group (wherein only one row of distal screws was used) using cadaveric forearm models of radius fractures fixed with a polyaxial locking plate. Fifteen fresh cadaveric forearms were surgically operated to generate an Arbeitsgemeinschaft für Osteosynthesefragen (AO) type 23-C2 fracture model with the fixation of polyaxial volar locking plates. The model specimens were randomized into two groups: DSS (n = 7) and NDSS (n = 8). Both the groups received 4 locking screws in the most distal row, as is usually applied, whereas the DSS group received 2 additional screws in the second row inserted at an inclination of about 15° to support the dorsal aspect of the dorsal subchondral bone. Cyclic axial compression test was performed (3000 cycles; 0-250 N; 60 mm/min) to measure absolute rigidity and displacement, after 1, 1000, 2000 and 3000 cycles, and values were normalized relative to cycle 1. These absolute and normalized values were compared between those two groups. Radiographic images were taken before and after the cyclic loading to measure changes in volar tilt (ΔVT) and radial inclination (ΔRI). The DSS group maintained significantly higher rigidity and lower displacement values than the NDSS group during the entire loading period. Radiographic analysis indicated that the ΔVT values of the DSS group were lower than those of the NDSS group. In contrast, the fixation design did not influence the impact of loading on the ΔRI values. Biomechanical and radiographic analyses demonstrated that two rows of distal locking screws in the DSS procedure conferred higher stability than one row of distal locking screws. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  11. Mutations in the Paxillin-binding Site of Integrin-linked Kinase (ILK) Destabilize the Pseudokinase Domain and Cause Embryonic Lethality in Mice*

    PubMed Central

    Moik, Daniel; Böttcher, Anika; Makhina, Tatiana; Grashoff, Carsten; Bulus, Nada; Zent, Roy; Fässler, Reinhard

    2013-01-01

    Integrin-linked kinase (ILK) localizes to focal adhesions (FAs) where it regulates cell spreading, migration, and growth factor receptor signaling. Previous reports showed that overexpressed ILK in which Val386 and Thr387 were substituted with glycine residues (ILK-VT/GG) could neither interact with paxillin nor localize to FA in cells expressing endogenous wild-type ILK, implying that paxillin binding to ILK is required for its localization to FAs. Here, we show that introducing this mutation into the germ line of mice (ILK-VT/GG) caused vasculogenesis defects, resulting in a general developmental delay and death at around embryonic day 12.5. Fibroblasts isolated from ILK-VT/GG mice contained mutant ILK in FAs, showed normal adhesion to and spreading on extracellular matrix substrates but displayed impaired migration. Biochemical analysis revealed that VT/GG substitutions decreased ILK protein stability leading to decreased ILK levels and reduced binding to paxillin and α-parvin. Because paxillin depletion did not affect ILK localization to FAs, the embryonic lethality and the in vitro migration defects are likely due to the reduced levels of ILK-VT/GG and diminished binding to parvins. PMID:23658024

  12. Pacing-induced palmar sweating evaluated by unique hygrometer: possible implications of sympathetic activation during tachycardia.

    PubMed

    Maruyama, T; Yanaga, T; Makino, N

    2000-03-01

    Although reflex sympathetic activation is a major determinant of the haemodynamic tolerability of ventricular tachycardia (VT), the methods for evaluating this aspect during on-going VT remain invasive and complicated. Palmar sweating as an indirect but non-invasive measure of sympathetic activity was estimated by means of a unique hygrometer under right ventricular (RV) rapid pacing (up to 150 beats min-1) replicating VT, and concurrent monitoring of aortic blood pressure in five patients with various kinds of cardiac arrhythmias in our electrophysiological laboratory. The peak palmar sweating rate in arbitrary units was augmented as the RV pacing rate increased and was proportional to the pacing-induced fall in systolic blood pressure (SBP), with a correlation coefficient of more than 0.903 (P<0.006). The slope of linearity between the sweating rate and the fall in SBP varied among individual patients, with greater sweating amplitude in the younger patients even with the same extent of fall in SBP. This preliminary study suggests sympathetic acceleration caused by haemodynamic deterioration under simulated VT, and therefore this protocol may be able to predict the haemodynamic tolerability of sustained monomorphic VT.

  13. The effect of ultradian and orbital cycles on plant growth

    NASA Technical Reports Server (NTRS)

    Berry, W.; Hoshizaki, T.; Ulrich, A.

    1986-01-01

    In a series of experiments using sugar beets, researchers investigated the effects of varying cycles lengths on growth (0.37 hr to 48 hr). Each cycle was equally divided into a light and dark period so that each treatment regardless of cycle length received the same amount of light over the 17 weeks of the experiment. Two growth parameters were used to evaluate the effects of cycle length, total fresh weight and sucrose content of the storage root. Both parameters showed very similar responses in that under long cycles (12 hr or greater) growth was normal, whereas plants growing under shorter cycle periods were progressively inhibited. Minimum growth occurred at a cycle period of 0.75 hr. The yield at the 0.75 hr cycle, where was at a minimum, for total fresh weight was only 51 percent compared to the 24 hr cycle. The yield of sucrose was even more reduced at 41 percent of the 24 hr cycle.

  14. 8. Photocopy of photograph (Original in possesssion of the Division ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. Photocopy of photograph (Original in possesssion of the Division of Mechanical and Cicil Engineering, Smithsonian Institute) PARKER TRUSS BRIDGE IN NORTHFIELD, VT - Elm Street Bridge, Spanning Ottauquechee River, Woodstock, Windsor County, VT

  15. Menstrual function among women exposed to polybrominated biphenyls: A follow-up prevalence study

    PubMed Central

    Davis, Stephanie I; Blanck, Heidi Michels; Hertzberg, Vicki S; Tolbert, Paige E; Rubin, Carol; Cameron, Lorraine L; Henderson, Alden K; Marcus, Michele

    2005-01-01

    Background Alteration in menstrual cycle function is suggested among rhesus monkeys and humans exposed to polybrominated biphenyls (PBBs) and structurally similar polychlorinated biphenyls (PCBs). The feedback system for menstrual cycle function potentially allows multiple pathways for disruption directly through the hypothalamic-pituitary-ovarian axis and indirectly through alternative neuroendocrine axes. Methods The Michigan Female Health Study was conducted during 1997–1998 among women in a cohort exposed to PBBs in 1973. This study included 337 women with self-reported menstrual cycles of 20–35 days (age range: 24–56 years). Current PBB levels were estimated by exponential decay modeling of serum PBB levels collected from 1976–1987 during enrollment in the Michigan PBB cohort. Linear regression models for menstrual cycle length and the logarithm of bleed length used estimated current PBB exposure or enrollment PBB exposure categorized in tertiles, and for the upper decile. All models were adjusted for serum PCB levels, age, body mass index, history of at least 10% weight loss in the past year, physical activity, smoking, education, and household income. Results Higher levels of physical activity were associated with shorter bleed length, and increasing age was associated with shorter cycle length. Although no overall association was found between PBB exposure and menstrual cycle characteristics, a significant interaction between PBB exposures with past year weight loss was found. Longer bleed length and shorter cycle length were associated with higher PBB exposure among women with past year weight loss. Conclusion This study suggests that PBB exposure may impact ovarian function as indicated by menstrual cycle length and bleed length. However, these associations were found among the small number of women with recent weight loss suggesting either a chance finding or that mobilization of PBBs from lipid stores may be important. These results should be replicated with larger numbers of women exposed to similar lipophilic compounds. PMID:16091135

  16. Effect of a microstructure and surface hydrogen alloying of a VT6 alloy on diffusion welding

    NASA Astrophysics Data System (ADS)

    Senkevich, K. S.; Skvortsova, S. V.; Kudelina, I. M.; Knyazev, M. I.; Zasypkin, V. V.

    2014-01-01

    The effect of a structural type (lamellar, fine, gradient) and additional surface alloying with hydrogen on the diffusion bonding of titanium alloy VT6 samples is studied. It is shown that the surface alloying of VT6 alloy parts with hydrogen allows one to decrease the diffusion welding temperature by 50-100°C, to obtain high-quality pore-free bonding, and to remove the "structural" boundary between materials to be welded that usually forms during welding of titanium alloys with a lamellar structure.

  17. A conceptual model of the Mount Spurr magmatic system from seismic and geochemical observations of the 1992 Crater Peak eruption sequence

    USGS Publications Warehouse

    Power, J.; Jolly, A.; Nye, C.; Harbin, M.

    2002-01-01

    A conceptual model of the geometry and dynamics of the Mount Spurr magmatic system is developed using seismic, geochemical, and visual observations of the 1992 Crater Peak eruption sequence. The basis for this model is a new classification of all located seismic events and results from prior studies of seismology, geology, geochemistry, and geophysics of the Mount Spurr area. Significant seismic features of the 1992 eruption sequence include (1) a distinct swarm of volcano-tectonic (VT) earthquakes in August 1991 directly beneath the Crater Peak vent, (2) a caldera-wide increase in VT earthquakes, lasting 7 months, which preceded the 27 June eruption, (3) two shallow swarms of VT earthquakes that occured on 5 June and 27 June, the latter immediately preceding the 27 June eruption, (4) a mix of VT, long-period (LP), and hybrid events at depths of 20-40 km, which began coincident with the onset of seismic unrest and reached a peak after eruptive activity ended, (5) a strong swarm of VT earthquakes that began as the 16-17 September eruption was ending, (6) a prominent swarm of VT earthquakes on 9-10 November at depths of 1 to 4 km beneath Crater Peak, and (7) a smaller swarm of VT earthquakes in late December 1992, which were located between 7 and 10 km depth. These seismic observations, combined with geological, geochemical, and geophysical data and observations, suggest a deep magmatic source zone for Crater Peak andesites at depths of 20-40 km, a smaller mid-crustal storage zone at about 10 km depth, and a conduit that extends to the surface. We infer that the magmas erupted in 1992 were generated at depths of 20-40 km and rose to the mid-crustal storage zone that fed all three 1992 eruptions. The 1992 eruption sequence may have terminated when additional magma solidified at shallow depths.

  18. Crystal Structure of the New Investigational Drug Candidate VT-1598 in Complex with Aspergillus fumigatus Sterol 14α-Demethylase Provides Insights into Its Broad-Spectrum Antifungal Activity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hargrove, Tatiana Y.; Garvey, Edward P.; Hoekstra, William J.

    ABSTRACT Within the past few decades, the incidence and complexity of human fungal infections have increased, and therefore, the need for safer and more efficient, broad-spectrum antifungal agents is high. In the study described here, we characterized the new tetrazole-based drug candidate VT-1598 as an inhibitor of sterol 14α-demethylase (CYP51B) from the filamentous fungusAspergillus fumigatus. VT-1598 displayed a high affinity of binding to the enzyme in solution (dissociation constant, 13 ± 1 nM) and in the reconstituted enzymatic reaction was revealed to have an inhibitory potency stronger than the potencies of all other simultaneously tested antifungal drugs, including fluconazole, voriconazole,more » ketoconazole, and posaconazole. The X-ray structure of the VT-1598/A. fumigatusCYP51 complex was determined and depicts the distinctive binding mode of the inhibitor in the enzyme active site, suggesting the molecular basis of the improved drug potency and broad-spectrum antifungal activity. These data show the formation of an optimized hydrogen bond between the phenoxymethyl oxygen of VT-1598 and the imidazole ring nitrogen of His374, the CYP51 residue that is highly conserved across fungal pathogens and fungus specific. Comparative structural analysis ofA. fumigatusCYP51/voriconazole andCandida albicansCYP51/VT-1161 complexes supports the role of H bonding in fungal CYP51/inhibitor complexes and emphasizes the importance of an optimal distance between this interaction and the inhibitor-heme iron interaction. Cellular experiments using twoA. fumigatusstrains (strains 32820 and 1022) displayed a direct correlation between the effects of the drugs on CYP51B activity and fungal growth inhibition, indicating the noteworthy anti-A. fumigatuspotency of VT-1598 and confirming its promise as a broad-spectrum antifungal agent.« less

  19. Visceral Thromboses in Pancreas Adenocarcinoma: Systematic Review.

    PubMed

    Hicks, Angel Mier; DeRosa, Antonio; Raj, Micheal; Do, Richard; Yu, Kenneth H; Lowery, Maeve A; Varghese, Anna; O'Reilly, Eileen M

    2018-06-01

    Within gastrointestinal malignancies, primary hepatocellular carcinoma and pancreatic ductal adenocarcinoma (PDAC) are frequently associated with visceral thromboses (VT). Thrombus formation in the portal (PVT), mesenteric (MVT), or splenic vein (SVT) system leads to portal hypertension and intestinal ischemia. VT in PDAC may convey a risk of increased distal thrombosis and poses therapeutic uncertainty regarding the role of anticoagulation. An increasing number of reports describe VT associated with PDAC. It is possible that early diagnosis of these events may help reduce morbidity and speculatively improve oncologic outcomes. To perform a systematic review to study PVT, MVT, and SVT associated with PDAC, and to provide a comprehensive review. Medline/PubMed, Embase, Web of Science, Scopus, and the Cochrane Library. Data Extraction and Assessment: Two blinded independent observers extracted and assessed the studies for diagnosis of PVT, MVT, and SVT in PDAC. Studies were restricted to English-language literature published between 2007 and 2016. Eleven articles were identified. Five case reports and 7 retrospective studies were found, with a total of 127 patients meeting the inclusion criteria. The mean age at diagnosis was 64 years. PVT was found in 35% (n = 46), SVT in 52% (n = 65), and MVT in 13% (n = 15). Mean follow-up time was 26 months. Only 3 of the selected articles studied the impact of anticoagulation in VT. All patients with nonvisceral thrombosis (eg, deep-vein thrombosis, pulmonary emboli) were therapeutically treated; in contrast, patients with VT only rarely received treatment. VT in PDAC is a frequent finding at diagnosis or during disease progression. Evidence to guide treatment choices is limited, and current management is based on inferred experience from nononcologic settings. Anticoagulation appears to be safe in VT, with most of the large studies recommending a careful assessment for patients at a high risk of bleeding. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Ventilatory protective strategies during thoracic surgery: effects of alveolar recruitment maneuver and low-tidal volume ventilation on lung density distribution.

    PubMed

    Kozian, Alf; Schilling, Thomas; Schütze, Hartmut; Senturk, Mert; Hachenberg, Thomas; Hedenstierna, Göran

    2011-05-01

    The increased tidal volume (V(T)) applied to the ventilated lung during one-lung ventilation (OLV) enhances cyclic alveolar recruitment and mechanical stress. It is unknown whether alveolar recruitment maneuvers (ARMs) and reduced V(T) may influence tidal recruitment and lung density. Therefore, the effects of ARM and OLV with different V(T) on pulmonary gas/tissue distribution are examined. Eight anesthetized piglets were mechanically ventilated (V(T) = 10 ml/kg). A defined ARM was applied to the whole lung (40 cm H(2)O for 10 s). Spiral computed tomographic lung scans were acquired before and after ARM. Thereafter, the lungs were separated with an endobronchial blocker. The pigs were randomized to receive OLV in the dependent lung with a V(T) of either 5 or 10 ml/kg. Computed tomography was repeated during and after OLV. The voxels were categorized by density intervals (i.e., atelectasis, poorly aerated, normally aerated, or overaerated). Tidal recruitment was defined as the addition of gas to collapsed lung regions. The dependent lung contained atelectatic (56 ± 10 ml), poorly aerated (183 ± 10 ml), and normally aerated (187 ± 29 ml) regions before ARM. After ARM, lung volume and aeration increased (426 ± 35 vs. 526 ± 69 ml). Respiratory compliance enhanced, and tidal recruitment decreased (95% vs. 79% of the whole end-expiratory lung volume). OLV with 10 ml/kg further increased aeration (atelectasis, 15 ± 2 ml; poorly aerated, 94 ± 24 ml; normally aerated, 580 ± 98 ml) and tidal recruitment (81% of the dependent lung). OLV with 5 ml/kg did not affect tidal recruitment or lung density distribution. (Data are given as mean ± SD.) The ARM improves aeration and respiratory mechanics. In contrast to OLV with high V(T), OLV with reduced V(T) does not reinforce tidal recruitment, indicating decreased mechanical stress.

  1. Catheter ablation of ventricular tachycardias using remote magnetic navigation: a consecutive case-control study.

    PubMed

    Szili-Torok, Tamas; Schwagten, Bruno; Akca, Ferdi; Bauernfeind, Tamas; Abkenari, Lara Dabiri; Haitsma, David; Van Belle, Yves; Groot, Natasja D E; Jordaens, Luc

    2012-09-01

    Remote Magnetic Navigation for VT Ablation. This study aimed to compare acute and late outcomes of VT ablation using the magnetic navigation system (MNS) to manual techniques (MAN) in patients with (SHD) and without (NSHD) structural heart disease. Ablation data of 113 consecutive patients (43 SHD, 70 NSHD) with ventricular tachycardia treated with catheter ablation at our center were analyzed. Success rate, complications, procedure, fluoroscopy, and ablation times, and recurrence rates were systematically recorded for all patients. A total of 72 patients were included in the MNS group and 41 patients were included in the MAN group. Patient age, gender, and right ventricular and left ventricular VT were equally distributed. Acute success was achieved in 59 patients in the MNS group (82%) versus 27 (66%) patients in the MAN group (P = 0.046). Overall procedural time (177 ± 79 vs 232 ± 99 minutes, P < 0.01) and mean patient fluoroscopy time (27 ± 19 vs 56 ± 32 minutes, P < 0.001) were all significantly lower using MNS. In NSHD pts, higher acute success was achieved with MNS (83,7% vs 61.9%, P = 0.049), with shorter procedure times (151 ± 57 vs 210 ± 96, P = 0.011), whereas in SHD-VT these were not significantly different. No major complications occurred in the MNS group (0%) versus 1 cardiac tamponade and 1 significantly damaged ICD lead in the MAN group (4.9%, NS). After follow-up (20 ± 11 vs 20 ± 10 months, NS), VT recurred in 14 pts (23.7%) in the MNS group versus 12 pts (44.4%) in the MAN group (P = 0.047). The use of MNS offers advantages for ablation of NSHD-VT, while it offers similar efficacy for SHD-VT. (J Cardiovasc Electrophysiol, Vol. 23, pp. 948-954, September 2012). © 2012 Wiley Periodicals, Inc.

  2. Crystal Structure of the New Investigational Drug Candidate VT-1598 in Complex with Aspergillus fumigatus Sterol 14α-Demethylase Provides Insights into Its Broad-Spectrum Antifungal Activity

    PubMed Central

    Hargrove, Tatiana Y.; Garvey, Edward P.; Hoekstra, William J.; Yates, Christopher M.; Wawrzak, Zdzislaw; Rachakonda, Girish; Villalta, Fernando

    2017-01-01

    ABSTRACT Within the past few decades, the incidence and complexity of human fungal infections have increased, and therefore, the need for safer and more efficient, broad-spectrum antifungal agents is high. In the study described here, we characterized the new tetrazole-based drug candidate VT-1598 as an inhibitor of sterol 14α-demethylase (CYP51B) from the filamentous fungus Aspergillus fumigatus. VT-1598 displayed a high affinity of binding to the enzyme in solution (dissociation constant, 13 ± 1 nM) and in the reconstituted enzymatic reaction was revealed to have an inhibitory potency stronger than the potencies of all other simultaneously tested antifungal drugs, including fluconazole, voriconazole, ketoconazole, and posaconazole. The X-ray structure of the VT-1598/A. fumigatus CYP51 complex was determined and depicts the distinctive binding mode of the inhibitor in the enzyme active site, suggesting the molecular basis of the improved drug potency and broad-spectrum antifungal activity. These data show the formation of an optimized hydrogen bond between the phenoxymethyl oxygen of VT-1598 and the imidazole ring nitrogen of His374, the CYP51 residue that is highly conserved across fungal pathogens and fungus specific. Comparative structural analysis of A. fumigatus CYP51/voriconazole and Candida albicans CYP51/VT-1161 complexes supports the role of H bonding in fungal CYP51/inhibitor complexes and emphasizes the importance of an optimal distance between this interaction and the inhibitor-heme iron interaction. Cellular experiments using two A. fumigatus strains (strains 32820 and 1022) displayed a direct correlation between the effects of the drugs on CYP51B activity and fungal growth inhibition, indicating the noteworthy anti-A. fumigatus potency of VT-1598 and confirming its promise as a broad-spectrum antifungal agent. PMID:28461309

  3. Use of a single ventilator to support 4 patients: laboratory evaluation of a limited concept.

    PubMed

    Branson, Richard D; Blakeman, Thomas C; Robinson, Bryce Rh; Johannigman, Jay A

    2012-03-01

    A mass-casualty respiratory failure event where patients exceed available ventilators has spurred several proposed solutions. One proposal is use of a single ventilator to support 4 patients. A ventilator was modified to allow attachment of 4 circuits. Each circuit was connected to one chamber of 2 dual-chambered, test lungs. The ventilator was set at a tidal volume (V(T)) of 2.0 L, respiratory frequency of 10 breaths/min, and PEEP of 5 cm H(2)O. Tests were repeated with pressure targeted breaths at 15 cm H(2)O. Airway pressure, volume, and flow were measured at each chamber. The test lungs were set to simulate 4 patients using combinations of resistance (R) and compliance (C). These included equivalent C and R, constant R and variable C, constant C and variable R, and variable C and variable R. When R and C were equivalent the V(T) distributed to each chamber of the test lung was similar during both volume (range 428-442 mL) and pressure (range 528-544 mL) breaths. Changing C while R was constant resulted in large variations in delivered V(T) (volume range 257-621 mL, pressure range 320-762 mL). Changing R while C was constant resulted in a smaller variation in V(T) (volume range 418-460 mL, pressure range 502-554 mL) compared to only C changes. When R and C were both varied, the range of delivered V(T) in both volume (336-517 mL) and pressure (417-676 mL) breaths was greater, compared to only R changes. Using a single ventilator to support 4 patients is an attractive concept; however, the V(T) cannot be controlled for each subject and V(T) disparity is proportional to the variability in compliance. Along with other practical limitations, these findings cannot support the use of this concept for mass-casualty respiratory failure.

  4. Successful ventricular tachycardia ablation in patients with electrical storm reduces recurrences and improves survival.

    PubMed

    Vergara, Pasquale; Tung, Roderick; Vaseghi, Marmar; Brombin, Chiara; Frankel, David; Di Biase, Luigi; Nagashima, Koichi; Tedrow, Usha; Tzou, Wendy S; Sauer, William H; Mathuria, Nilesh; Nakahara, Shiro; Vakil, Kairav; Tholakanahalli, Venkat; Bunch, T Jared; Weiss, J Peter; Dickfeld, Timm; Vunnam, Rama; Lakireddy, Dhanunjaya; Burkhardt, J David; Correra, Anna; Santangeli, Pasquale; Callans, David; Natale, Andrea; Marchlinski, Francis; Stevenson, William G; Shivkumar, Kalyanam; Della Bella, Paolo

    2018-01-01

    The purpose of this study was to evaluate the characteristics and outcome of patients undergoing ablation after electrical storm (ES). Clinical and procedural characteristics, ventricular tachycardia (VT) recurrence, and mortality rates from 1940 patients undergoing VT ablation were compared between patients with and without ES. The group of 677 patients with ES (34.9%) were older, were more frequently men, and had a lower ejection fraction, more advanced heart failure, and a higher prevalence of cardiovascular comorbidities as compared with those without ES (86.1% patients with ES had ≥2 comorbidities vs 71.4%; P < .001). Patients with ES had more inducible VTs (2.5 ± 1.8 vs 1.9 ± 1.9; P < .001), required longer procedures (296.1 ± 119.1 minutes vs 265.7 ± 110.3 minutes; P < .001), and had a higher in-hospital mortality (42 deaths [6.2%] vs 18 deaths [1.4%]; P < .001). At 1-year follow-up, patients with ES experienced a higher risk of VT recurrence and mortality (32.1% vs 22.6% and 20.1% vs 8.5%; long-rank, P < .001 for both). Among patients with ES, those without any inducible VT after ablation had a higher survival rate (86.3%) than did those with nonclinical VTs only (72.9%), those with clinical VTs inducible at programmed electrical stimulation (51.2%), and not-tested patients (65.0%) (long-rank, P < .001 for all). In multivariate analysis, ES remained an independent predictor of in-hospital mortality, VT recurrence, and 1-year mortality (P < .001). Patients with ES have a high risk of VT recurrence and mortality. Patient and procedure characteristics are consistent with advanced cardiac disease and longer and more complex procedures. In patients with ES, acute procedural success is associated with a significant reduction in VT recurrence and improved 1-year survival. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  5. Long-term outcome of surgical cryoablation for refractory ventricular tachycardia in patients with non-ischemic cardiomyopathy.

    PubMed

    Liang, Jackson J; Betensky, Brian P; Muser, Daniele; Zado, Erica S; Anter, Elad; Desai, Nimesh D; Callans, David J; Deo, Rajat; Frankel, David S; Hutchinson, Mathew D; Lin, David; Riley, Michael P; Schaller, Robert D; Supple, Gregory E; Santangeli, Pasquale; Acker, Michael A; Bavaria, Joseph E; Szeto, Wilson Y; Vallabhajosyula, Prashanth; Marchlinski, Francis E; Dixit, Sanjay

    2018-03-01

    Limited data exist on the long-term outcome of patients (pts) with non-ischemic cardiomyopathy (NICM) and ventricular tachycardia (VT) refractory to conventional therapies undergoing surgical ablation (SA). We aimed to investigate the long-term survival and VT recurrence in NICM pts with VT refractory to radiofrequency catheter ablation (RFCA) who underwent SA. Consecutive pts with NICM and VT refractory to RFCA who underwent SA were included. VT substrate was characterized in the electrophysiology lab and targeted by RFCA. During SA, previous RFCA lesions/scars were identified and targeted with cryoablation (CA; 3 min/lesion; target -150 °C). Follow-up comprised office visits, ICD interrogations and the social security death index. Twenty consecutive patients with NICM who underwent SA (age 53 ± 16 years, 18 males, LVEF 41 ± 20%; dilated CM = 9, arrhythmogenic right ventricular CM = 3, hypertrophic CM = 2, valvular CM = 4, and mixed CM = 2) were studied. Percutaneous mapping/ablation in the electrophysiology lab was performed in 18 and 2 pts had primary SA. During surgery, 4.9 ± 4.0 CA lesions/pt were delivered to the endocardium (2) and epicardium (11) or both (7). VT-free survival was 72.5% at 1 year and over 43 ± 31 months (mos) (range 1-83mos), there was only one arrhythmia-related death. There was a significant reduction in ICD shocks in the 3-mos preceding SA vs. the entire follow-up period (6.6 ± 4.9 vs. 2.3 ± 4.3 shocks/pt, P = 0.001). In select pts with NICM and VT refractory to RFCA, SA guided by pre-operative electrophysiological mapping and ablation may be a therapeutic option. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  6. Announcing the Venus Transit 2004 (VT-2004) Programme

    NASA Astrophysics Data System (ADS)

    2004-02-01

    Rare Celestial Event to be Observed by Millions Summary On June 8, 2004, Venus - the Earth's sister planet - will pass in front of the Sun. This event, a 'transit', is extremely rare - the last one occurred in 1882, 122 years ago. Easily observable in Europe, Asia, Africa and Australia, it is likely to attract the attention of millions of people on these continents and, indeed, all over the world. On this important occasion, the European Southern Observatory (ESO) has joined forces with the European Association for Astronomy Education (EAAE), the Institut de Mécanique Céleste et de Calcul des Éphémérides (IMCCE) and the Observatoire de Paris in France, as well as the Astronomical Institute of the Academy of Sciences of the Czech Republic to establish the Venus Transit 2004 (VT-2004) public education programme. It is supported by the European Commission in the framework of the European Science and Technology Week and takes advantage of this extraordinary celestial event to expose the public - in a well-considered, interactive and exciting way - to a number of fundamental issues at the crucial interface between society and basic science. VT-2004 has several components, including an instructive and comprehensive website (www.vt-2004.org). It is directed towards the wide public in general and the media, school students and their teachers, as well as amateur astronomers in particular. It invites all interested persons to participate actively in the intercontinental VT-2004 Observing Campaign (that reenacts historical Venus Transit observations) and the VT-2004 Video Contest. During the VT-2004 Final Event in November, the winners of the Video Contest will be chosen by an international jury. This meeting will also serve to discuss the project and its impact. The outcome of this rare celestial event and the overall experience from this unique public education project will clearly be of very wide interest, not just in the field of astronomy.

  7. Arrhythmic effects of Epac-mediated ryanodine receptor activation in Langendorff-perfused murine hearts are associated with reduced conduction velocity.

    PubMed

    Li, Mengye; Hothi, Sandeep S; Salvage, Samantha C; Jeevaratnam, Kamalan; Grace, Andrew A; Huang, Christopher L-H

    2017-06-01

    Recent papers have attributed arrhythmic substrate in murine RyR2-P2328S hearts to reduced action potential (AP) conduction velocities (CV), reflecting acute functional inhibition and/or reduced expression of sodium channels. We explored for acute effects of direct exchange protein directly activated by cAMP (Epac)-mediated ryanodine receptor-2 (RyR2) activation on arrhythmic substrate and CV. Monophasic action potential (MAP) recordings demonstrated that initial steady (8 Hz) extrinsic pacing elicited ventricular tachycardia (VT) in 0 of 18 Langendorff-perfused wild-type mouse ventricles before pharmacological intervention. The Epac activator 8-CPT (8-(4-chlorophenylthio)-2'-O-methyladenosine-3',5'-cyclic monophosphate) (VT in 1 of 7 hearts), and the RyR2 blocker dantrolene, either alone (0 of 11) or with 8-CPT (0 of 9) did not then increase VT incidence (P>.05). Both progressively increased pacing rates and programmed extrasystolic (S2) stimuli similarly produced no VT in untreated hearts (n=20 and n=9 respectively). 8-CPT challenge then increased VT incidences (5 of 7 and 4 of 8 hearts respectively; P<.05). However, dantrolene, whether alone (0 of 10 and 1 of 13) or combined with 8-CPT (0 of 10 and 0 of 13) did not increase VT incidence relative to those observed in untreated hearts (P>.05). 8-CPT but not dantrolene, whether alone or combined with 8-CPT, correspondingly increased AP latencies (1.14±0.04 (n=7), 1.04±0.03 (n=10), 1.09±0.05 (n=8) relative to respective control values). In contrast, AP durations, conditions for 2:1 conduction block and ventricular effective refractory periods remained unchanged throughout. We thus demonstrate for the first time that acute RyR2 activation reversibly induces VT in specific association with reduced CV. © 2017 The Authors. Clinical and Experimental Pharmacology and Physiology Published by John Wiley & Sons Australia, Ltd.

  8. RadNet Air Data From Burlington, VT

    EPA Pesticide Factsheets

    This page presents radiation air monitoring and air filter analysis data for Burlington, VT from EPA's RadNet system. RadNet is a nationwide network of monitoring stations that measure radiation in air, drinking water and precipitation.

  9. A Lenz's law experiment revisited

    NASA Astrophysics Data System (ADS)

    Sawicki, Charles A.

    2000-10-01

    A dipole magnet model predicts a terminal velocity VT proportional to 1/n for n attached identical cylindrical magnets dropped down a copper pipe. Experiments show that VT increases approximately linearly with n. The explanation for this difference is presented.

  10. MAGNITUDE STUDIES CONDUCTED UNDER PROJECTS VT/5054 AND VT/5055.

    DTIC Science & Technology

    statistical model for Blue Mountains Seismological Observatory, Cumberland Plateau Seismological Observatory, Tonto Forest Seismological Observatory, Uinta ... Basin Seismological Observatory, and Wichita Mountains Seismological Observatory. Azimuthal dependence of station correction is not established at any of

  11. [Detection of verotoxin-producing E. coli (VTEC) in healthy cattle and swine with the DNA-DNA colony hybridization method].

    PubMed

    Bülte, M; Montenegro, M A; Helmuth, R; Trumpf, T; Reuter, G

    1990-11-01

    With the DNA-DNA colony hybridization technique using specific gene probes for Verotoxin 1 (VT 1) and Verotoxin 2 (VT 2) 2100 E. coli strains from healthy animals were tested. Ten out of 82 milk cows (21.2%), 20 out of 212 beef cattle (9.4%) and five out of 75 pigs (6.7%) were found to carry genes for VT 1, VT 2 or both toxins, respectively. Among these strains the biotypes 5 and 6 were predominant. Some of the serotyped isolates have been described to be pathogenic for humans, like O157:H7, 082:H8, 0116, 0113, 0126 and 091, respectively. The unexpected high incidence of VTEC positive healthy animals possibly indicates a health hazard for human beings. Further investigations on the incidence of VTEC in food are necessary.

  12. Rapid dike intrusion into Sakurajima volcano on August 15, 2015, as detected by multi-parameter ground deformation observations

    NASA Astrophysics Data System (ADS)

    Hotta, Kohei; Iguchi, Masato; Tameguri, Takeshi

    2016-04-01

    We present observations of ground deformation at Sakurajima in August 2015 and model the deformation using a combination of GNSS, tilt and strain data in order to interpret a rapid deformation event on August 15, 2015. The pattern of horizontal displacement during the period from August 14 to 16, 2015, shows a WNW-ESE extension, which suggests the opening of a dike. Using a genetic algorithm, we obtained the position, dip, strike length, width and opening of a dislocation source based on the combined data. A nearly vertical dike with a NNE-SSW strike was found at a depth of 1.0 km below sea level beneath the Showa crater. The length and width are 2.3 and 0.6 km, respectively, and a dike opening of 1.97 m yields a volume increase of 2.7 × 106 m3. 887 volcano-tectonic (VT) earthquakes beside the dike suggest that the rapid opening of the dike caused an accumulation of strain in the surrounding rocks, and the VT earthquakes were generated to release this strain. Half of the total amount of deformation was concentrated between 10:27 and 11:54 on August 15. It is estimated that the magma intrusion rate was 1 × 106 m3/h during this period. This is 200 times larger than the magma intrusion rate prior to one of the biggest eruptions at the summit crater of Minami-dake on July 24, 2012, and 2200 times larger than the average magma intrusion rate during the period from October 2011 to March 2012. The previous Mogi-type ground deformation is considered to be a process of magma accumulation in preexisting spherical reservoirs. Conversely, the August 2015 event was a dike intrusion and occurred in a different location to the preexisting reservoirs. The direction of the opening of the dike coincides with the T-axes and direction of faults creating a graben structure.

  13. Host selection and gonotrophic cycle length of Anopheles punctimacula in southern Mexico.

    PubMed

    Ulloa, Armando; Gonzalez-Cerón, Lilia; Rodríguez, Mario H

    2006-12-01

    The host preference, survival rates, and length of the gonotrophic cycle of Anopheles punctimacula was investigated in southern México. Mosquitoes were collected in 15-day separate experiments during the rainy and dry seasons. Daily changes in the parous-nulliparous ratio were recorded and the gonotrophic cycle length was estimated by a time series analysis. Anopheles punctimacula was most abundant during the dry season and preferred animals to humans. The daily survival rate in mosquitoes collected in animal traps was 0.96 (parity rate = 0.86; gonotrophic cycle = 4 days). The length of gonotrophic cycle of 4 days was estimated on the base of a high correlation coefficient value appearing every 4 days. The minimum time estimated for developing mature eggs after blood feeding was 72 h. The proportion of mosquitoes living enough to transmit Plasmodium vivax malaria during the dry season was 0.35.

  14. Phenotype and genotype of Escherichia coli isolated from pigs with postweaning diarrhea in Hungary.

    PubMed Central

    Nagy, B; Casey, T A; Moon, H W

    1990-01-01

    A total of 205 Escherichia coli isolates from 88 diarrheal weanling (4- to 10-week-old) pigs from 59 farms were tested by slide agglutination for K88, K99, F41, and 987P antigens. K88 antigen was detected in 61% of the isolates representing 60% of the pigs and 56% of the farms. K88 antigen was associated with serogroup O149 and 91% of the K88+ isolates. K99, F41, and 987P were not detected. Of the K88- isolates, 70 were additionally tested by colony hybridization with DNA probes for adherence factors K88, K99, 987P, and F41 and for enterotoxin genes STaP, STaH, STb, and LT and by Vero cell assay for verotoxins (VT). The 70 K88- isolates could be divided into three categories: LT-, VT-, STaP+, and/or STb+ (34 isolates); LT-, STaP+, STb+, and/or VT+ (17 isolates); and nontoxigenic (19 isolates). Only one of the K88- isolates carried a known adherence factor (987P) detectable with DNA probes. Most of the STaP+ and STb+ isolates belonged to O groups O141, O147, and O157. All but 1 of the 17 VT+ isolates belonged to O groups O138, O139, O141, and O149. Only three of the VT+ strains were isolated from pigs with edema disease. We concluded that 73% of the K88- isolates had the capability to produce enterotoxins or VT that could have contributed to weanling pig diarrhea. PMID:1970575

  15. Phase mapping of radionuclide gated biventriculograms in patients with sustained ventricular tachycardia or Wolff-Parkinson-White syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Le Guludec, D.; Bourguignon, M.; Sebag, C.

    1987-01-01

    Accuracy of Fourier phase mapping of radionuclide gated biventriculograms in detecting the origin of abnormal ventricular activation was studied during ventricular tachycardia or preexcitation. Group I included six patients suffering from clinical recurrent VT; 3 gated blood pool studies were acquired for each patient: during sinus rhythm, right ventricular pacing, and induced sustained VT-Group II included seven patients with Wolff-Parkinson-White syndrome and recurrent paroxysmal tachycardia; 3 gated blood pool studies were acquired for each patient: during sinus rhythm, right atrial pacing and orthodromic reciprocating tachycardia. Each acquisition lasted 5 min, in 30 degrees-40 degrees left anterior oblique projection. In Groupmore » I, the Fourier phase mapping was consistent with QRS morphology and axis during VT (5/6), except in one patient with LV aneurysm and LBBB electrical pattern during VT. Origin of VT on phase mapping was located in the right ventricle (n = 2) or in left ventricle (n = 4), at the border of wall motion abnormalities each time they existed (5/6). In Group II, the phase advance correlated with the location of the accessory pathway determined by ECG and endocardial mapping (n = 6) and per-operative epicardial mapping (n = 1). Discrimination between anterior and posterior localization of paraseptal pathways and location of intermittent preexcitation was not possible. We conclude that Fourier phase mapping is an accurate method for locating the origin of VT and determining its etiology. It can help locate the site of ventricular preexcitation in patients with only one accessory pathway; its accuracy in locating multiple accessory pathways remains unknown.« less

  16. Wastewater toxicity of tannin- versus chromium-based leather tanneries in Marrakesh, Morocco.

    PubMed

    De Nicola, E; Meriç, S; Della Rocca, C; Gallo, M; Iaccarino, M; Manini, P; Petruzzelli, D; Belgiorno, V; Cheggour, M; Di Gennaro, A; Moukrim, A; Tünay, O; Pagano, G

    2007-10-01

    The toxicity of leather tanning wastewater from a traditional tannery (TT), which is based on vegetable tannin (VT), was compared with wastewater from a tannery combining the use of chromium-based tanning (CT) with VT-based tanning operations. Wastewater samples from a TT and a CT plant as well as from five sewer sampling points were collected in Marrakesh, Morocco, and the concentrations of VT and some selected inorganics were measured. A set of bioassays were used to test wastewater toxicity in sea urchin (Paracentrotus lividus) embryos and sperm, in Daphnia magna, and in marine microalgae (Dunaliella tertiolecta). Toxicity end points included: (1) developmental defects, embryonic mortality, sperm fertilization success, and offspring damage in sea urchins; (2) D. magna immobilization; and (3) algal growth rate inhibition. Toxicity tests on TT and CT effluents (TTE and CTE) were run at dilutions ranging from 0.1% to 2% (sea urchins and algae) or up to 12% in D. magna. Parallel bioassays were run on VT extract (VTE) at nominal tannin concentrations ranging from 0.1 to 10 mg l(-1). The results showed higher toxicity of CTE compared with TTE. CTE toxicity in sea urchins and algae showed concentration-related trends, whereas TTE exerted hormetic effects at levels of 0.1% to 0.2% and toxic effects at levels >or=1%. The same trends were observed for VTE, suggesting a prevailing role of tannin in TTE-associated effects. The moderate wastewater toxicity of VT-based tanneries might prompt interest in the VT tanning process.

  17. Ventilatory effects of gap junction blockade in the RTN in awake rats.

    PubMed

    Hewitt, Amy; Barrie, Rachel; Graham, Michael; Bogus, Kara; Leiter, J C; Erlichman, Joseph S

    2004-12-01

    We tested the hypothesis that carbenoxolone, a pharmacological inhibitor of gap junctions, would reduce the ventilatory response to CO(2) when focally perfused within the retrotrapezoid nucleus (RTN). We tested this hypothesis by measuring minute ventilation (V(E)), tidal volume (V(T)), and respiratory frequency (F(R)) responses to increasing concentrations of inspired CO(2) (Fi(CO(2)) = 0-8%) in rats during wakefulness. We confirmed that the RTN was chemosensitive by perfusing the RTN unilaterally with either acetazolamide (AZ; 10 microM) or hypercapnic artificial cerebrospinal fluid equilibrated with 50% CO(2) (pH approximately 6.5). Focal perfusion of AZ or hypercapnic aCSF increased V(E), V(T), and F(R) during exposure to room air. Carbenoxolone (300 microM) focally perfused into the RTN decreased V(E) and V(T) in animals <11 wk of age, but V(E) and V(T) were increased in animals >12 wk of age. Glyzyrrhizic acid, a congener of carbenoxolone, did not change V(E), V(T), or F(R) when focally perfused into the RTN. Carbenoxolone binds to the mineralocorticoid receptor, but spironolactone (10 microM) did not block the disinhibition of V(E) or V(T) in older animals when combined with carbenoxolone. Thus the RTN is a CO(2) chemosensory site in all ages tested, but the function of gap junctions in the chemosensory process varies substantially among animals of different ages: gap junctions amplify the ventilatory response to CO(2) in younger animals, but appear to inhibit the ventilatory response to CO(2) in older animals.

  18. 33 CFR 110.8 - Lake Champlain, N.Y. and Vt.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... ANCHORAGES ANCHORAGE REGULATIONS Special Anchorage Areas § 110.8 Lake Champlain, N.Y. and Vt. (a) Ticonderoga...°14′05″ W. Note: The anchoring of vessels and placement of temporary moorings in the anchorage area...

  19. 33 CFR 110.8 - Lake Champlain, N.Y. and Vt.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... ANCHORAGES ANCHORAGE REGULATIONS Special Anchorage Areas § 110.8 Lake Champlain, N.Y. and Vt. (a) Ticonderoga...°14′05″ W. Note: The anchoring of vessels and placement of temporary moorings in the anchorage area...

  20. 33 CFR 110.8 - Lake Champlain, N.Y. and Vt.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... ANCHORAGES ANCHORAGE REGULATIONS Special Anchorage Areas § 110.8 Lake Champlain, N.Y. and Vt. (a) Ticonderoga...°14′05″ W. Note: The anchoring of vessels and placement of temporary moorings in the anchorage area...

  1. 33 CFR 110.8 - Lake Champlain, N.Y. and Vt.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... ANCHORAGES ANCHORAGE REGULATIONS Special Anchorage Areas § 110.8 Lake Champlain, N.Y. and Vt. (a) Ticonderoga...°14′05″ W. Note: The anchoring of vessels and placement of temporary moorings in the anchorage area...

  2. In-flight automated external defibrillator use and consultation patterns

    PubMed Central

    Brown, AM; Rittenberger, JC; Ammon, CM; Harrington, S; Guyette, FX

    2010-01-01

    Background Limited information exists about the in-flight use and outcomes associated with automatic external defibrillators (AED) on commercial airlines. Methods We collected self-reported cases of AED use to an airline consultation service from three US airlines between May 2004 and March 2009. We reviewed all available data files, related consult forms, and recordings. For each case, demographics, initial rhythm, shock delivery/success, survival to admission, and ground medical consultation use were obtained. Success was defined as the return of a perfusing rhythm. Initial rhythms were classified as: sinus, heart block, SVT, atrial fibrillation/flutter, asystole, PEA and VF/VT. Results There were a total of 169 AED applications with 40 cardiac arrests. The mean ages were 58 years (SD 15) and 63 years (SD 12) respectively; both populations were 64% male. AEDs were applied for monitoring in 129 (76%) cases with initial rhythms of: sinus 114 (88%); atrial fibrillation/flutter 7 (5%); complete heart block 4 (3%); and SVT 4 (3%). Presenting rhythms among the cardiac arrest population were: asystole 16 (40%); ventricular fibrillation/ventricular tachycardia 10 (25%); and PEA 14 (35%). Fourteen patients were defibrillated including nine of the 10 patients with initial VF/VT and five for the presence of VF/VT after resuscitation for initial PEA/asystole. Defibrillation was advised but not performed in the remaining case of initial VF/VT and no medical consult was obtained. All five successful defibrillations occurred in patients with initial VF/VT. There were 6 (15%; 95% CI 3–27%) survivors with 5 occurring after successful defibrillation for initial VF/VT and one with return of a perfusing rhythm after CPR for a junctional rhythm. Survival in those with VF/VT was 5/10 (50%; 95% CI 14–86%). Medications were delivered twice. The median time to first shock was 19 (IQR 12–24) seconds from AED application. Medical consultation was obtained in 56 (33%) of the 169 AED cases and 14 (35%) of the cardiac arrests. Conclusion AEDs resulted in 50% survival among those with VT/VF in-flight and 14% overall survival for cardiac arrest. Survival is poor among patients presenting with non-shockable rhythms. AEDs are used extensively for in-flight monitoring with significant rhythms identified. Ground medical consultation is sought in only one-third of AED uses and cardiac arrests. PMID:20128705

  3. Certain relativistic phenomena in crystal optics

    NASA Astrophysics Data System (ADS)

    Chee-Seng, Lim

    1980-01-01

    Relativistic unsteady phenomena are established for a crystalline medium with unaligned sets of permittivity and permeability principal axes, but incorporating a compounded uniaxiality about some nonprincipal direction. All effects originate from a suddenly activated, arbitrarily oriented, maintained line current conducted with a finite velocity v. Integral representations studied in another paper (Chee-Seng) are applied. The original coordinate system is subjected to a series of rotational and translational, scaled and unscaled transformations. No specific coordinate frame is strictly adhered to. Instead, it is often expedient and advantageous to exploit several reference frames simultaneously in the course of the analysis and interpretations. The electric field is directly related to a net scalar field Δ involving another scalar Ψ and its complement Ψ¯ which can be deduced from Ψ; Ψ and Ψ¯ are associated with two expanding, inclined ellipsoidal wavefronts ξ and ξ¯; these are cocentered at the current origin and touch each other twice along the uniaxis. Elsewhere, ξ leads ξ¯. For a source current faster than ξ:vt ∈ extξ, Ψ≢0 within a finite but growing ''ice-cream cone'' domain, its nontrivial composition being χ-1/2 inside ξ and 2χ-1/2 inside part of a tangent cone from the advancing current edge vt to, and terminating at, ξ; the function χ vanishes along such a tangent cone. Alternatively, for a source current slower than ξ:vt∈ intξ, if vt is avoided, χ≳0 everywhere, while Ψ=χ-1/2 inside ξ but vanishes identically outside ξ. However, the crucial scalar field Δ depends on three separate current-velocity regimes. Over a slow regime: vt∈ intξ¯, Δ is nontrivial inside ξ wherein it is discontinuous across ξ¯. Over an intermediate regime: vt ∈ intξ extξ¯, Δ takes four distinct forms on 12 adjacent domains bounded by ξ, ξ¯ and a double-conical tangent surface linking vt to ξ¯. But for a fast regime: vt∈ extξ, Δ assumes six distinct forms on 18 adjacent domains bounded by ξ, ξ¯ plus two double-conical tangent surfaces, convertexed at vt, to both ξ and ξ¯. Singularities are normally confined to these boundaries. Relative to a moving frame, χ is time-independent. Nevertheless, Ψ and, consequently, Δ evolve unsteadily, principally because of transitions across the expanding ellipsoids ξ and ξ¯ which also acquire a relative retreat from the current edge vt. An evolution scheme is discussed in detail. This produces, among other things, a steady state corollary which, in turn, covers Čerenkov radiation. A quadrical symmetry exists with respect to a family {Qν} of constant χ-surfaces. These are quadric surfaces cocentered at vt and having principal axes inclined to those of ξ (and ξ¯). Their interactions with ξ are closely examined. If vt ∈ extξ, each Qν is a hyperboloid of two sheets which are asymptotic to the double-conical tangent surface connecting ξ to vt; Ψ can become nontrivial on only one sheet, viz., that which is approached by ξ as the latter retreats from vt; eventually, two permanent intersections, one following the other, occur along two expanding and travelling parallel plane circuits. But if vt ∈ intξ, each Qν is an ellipsoid inside which ξ initially evolves until an encounter occurs, first as a point contact which immediately grows into a plane circuit; as this traverses Qν, it expands and then contracts to a diametrically opposite point where contact breaks off. Finally, an elliptical axisymmetry about a principal direction of {Qν} is demonstrated. Corresponding behaviors hold in relation to ξ¯.

  4. Increasing serum 25-hydroxyvitamin D (25(OH)D) is associated with reduced odds of long menstrual cycles in a cross-sectional study of African-American women

    PubMed Central

    Upson, Kristen; Harmon, Quaker E.; Baird, Donna D.

    2016-01-01

    Objective To examine the association between serum 25-hydroxyvitamin D (25(OH)D) and menstrual cycle length and regularity. Design Community-based, cross-sectional study of serum 25(OH)D (adjusted for seasonal differences in timing of blood draw) and menstrual cycle length. Women ages 23-34 reported their gynecologic history. Menstrual cycles were described with four independent categories (normal, short, long, irregular). We used polytomous logistic regression to estimate the association between a doubling of seasonally-adjusted 25(OH)D and the odds of each cycle category. Setting Women from the Detroit, Michigan area attended a study clinic visit. Participants 1102 African-American women ages 23-34. Intervention None Main Outcome Measure Self-reported menstrual cycle length over the previous 12 months excluding women who were using cycle-regulating medications over the entire year. Women who reported that their cycles were “too irregular to estimate” were classified as having irregular cycles. A typical cycle length of <27 days was considered “short,” >34 days was “long,” and 27-34 days was “normal”. Results The median 25(OH)D level was 14.7 ng/ml (interquartile range: 10.9, 19.6). A doubling of 25(OH)D was associated with half the odds of having long menstrual cycles (adjusted odds ratio (aOR) (95% Confidence interval (CI): 0.54 (0.32, 0.89)). 25(OH)D was not associated with the occurrence of short (aOR(CI): 1.03 (0.82, 1.29)) or irregular (aOR(CI): 1.46 (0.88, 2.41) menstrual cycles. Results were robust to several sensitivity analyses. Conclusions These findings suggest that vitamin D status may influence the menstrual cycle and play a role in ovarian function. Further investigation of 25(OH)D and ovarian hormones, and prospective studies of 25(OH)D and cycle length, are needed. PMID:26997249

  5. Increasing serum 25-hydroxyvitamin D is associated with reduced odds of long menstrual cycles in a cross-sectional study of African American women.

    PubMed

    Jukic, Anne Marie Z; Upson, Kristen; Harmon, Quaker E; Baird, Donna D

    2016-07-01

    To examine the association between serum 25-hydroxyvitamin D [25(OH)D] and menstrual cycle length and regularity. Community-based, cross-sectional study of serum 25(OH)D (adjusted for seasonal differences in timing of blood draw) and menstrual cycle length. Women aged 23-34 years reported their gynecologic history. Menstrual cycles were described with four independent categories (normal, short, long, irregular). We used polytomous logistic regression to estimate the association between a doubling of seasonally adjusted 25(OH)D and the odds of each cycle category. Not applicable. A total of 1,102 African American women. Not applicable. Self-reported menstrual cycle length over the previous 12 months, excluding women who were using cycle-regulating medications over the entire year. Women who reported that their cycles were "too irregular to estimate" were classified as having irregular cycles. A typical cycle length of <27 days was considered "short," >34 days was "long," and 27-34 days was "normal." The median 25(OH)D level was 14.7 ng/mL (interquartile range, 10.9-19.6 ng/mL). A doubling of 25(OH)D was associated with half the odds of having long menstrual cycles: adjusted odds ratio (aOR) 0.54, 95% confidence interval (CI) 0.32-0.89. 25-Hydroxyvitamin D was not associated with the occurrence of short (aOR 1.03, 95% CI 0.82-1.29) or irregular (aOR 1.46, 95% CI 0.88-2.41) menstrual cycles. Results were robust to several sensitivity analyses. These findings suggest that vitamin D status may influence the menstrual cycle and play a role in ovarian function. Further investigation of 25(OH)D and ovarian hormones, and prospective studies of 25(OH)D and cycle length, are needed. Copyright © 2016 American Society for Reproductive Medicine. All rights reserved.

  6. 76 FR 59479 - Vermont Disaster Number VT-00021

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-26

    ... SMALL BUSINESS ADMINISTRATION [Disaster Declaration 12784 and 12785] Vermont Disaster Number VT-00021 AGENCY: U.S. Small Business Administration. ACTION: Amendment 5. SUMMARY: This is an amendment of... original declaration remains unchanged. (Catalog of Federal Domestic Assistance Numbers 59002 and 59008...

  7. 76 FR 58329 - Vermont Disaster Number VT-00021

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-20

    ... SMALL BUSINESS ADMINISTRATION [Disaster Declaration 12784 and 12785] Vermont Disaster Number VT-00021 AGENCY: U.S. Small Business Administration. ACTION: Amendment 4. SUMMARY: This is an amendment of... in the original declaration remains unchanged. (Catalog of Federal Domestic Assistance Numbers 59002...

  8. Volcano-tectonic earthquakes: A new tool for estimating intrusive volumes and forecasting eruptions

    USGS Publications Warehouse

    White, Randall A.; McCausland, Wendy

    2016-01-01

    Notable cases in which distal VT events preceded eruptions at long-dormant volcanoes include: Nevado del Ruiz (1984–1985), Pinatubo (1991), Unzen (1989–1995), Soufriere Hills (1995), Shishaldin (1989–1999), Tacana' (1985–1986), Pacaya (1980–1984), Rabaul (1994), and Cotopaxi (2001). Additional cases are recognized at frequently active volcanoes including Popocateptl (2001–2003) and Mauna Loa (1984). We present four case studies (Pinatubo, Soufriere Hills, Unzen, and Tacana') in which we demonstrate the above mentioned VT characteristics prior to eruptions. Using regional data recorded by NEIC, we recognized in near-real time that a huge distal VT swarm was occurring, deduced that a proportionately huge magmatic intrusion was taking place beneath the long dormant Sulu Range, New Britain Island, Papua New Guinea, that it was likely to lead to eruptive activity, and warned Rabaul Volcano Observatory days before a phreatic eruption occurred. This confirms the value of this technique for eruption forecasting. We also present a counter-example where we deduced that a VT swarm at Volcan Cosiguina, Nicaragua, indicated a small intrusion, insufficient to reach the surface and erupt. Finally, we discuss limitations of the method and propose a mechanism by which this distal VT seismicity is triggered by magmatic intrusion.

  9. Short-term volcano-tectonic earthquake forecasts based on a moving mean recurrence time algorithm: the El Hierro seismo-volcanic crisis experience

    NASA Astrophysics Data System (ADS)

    García, Alicia; De la Cruz-Reyna, Servando; Marrero, José M.; Ortiz, Ramón

    2016-05-01

    Under certain conditions, volcano-tectonic (VT) earthquakes may pose significant hazards to people living in or near active volcanic regions, especially on volcanic islands; however, hazard arising from VT activity caused by localized volcanic sources is rarely addressed in the literature. The evolution of VT earthquakes resulting from a magmatic intrusion shows some orderly behaviour that may allow the occurrence and magnitude of major events to be forecast. Thus governmental decision makers can be supplied with warnings of the increased probability of larger-magnitude earthquakes on the short-term timescale. We present here a methodology for forecasting the occurrence of large-magnitude VT events during volcanic crises; it is based on a mean recurrence time (MRT) algorithm that translates the Gutenberg-Richter distribution parameter fluctuations into time windows of increased probability of a major VT earthquake. The MRT forecasting algorithm was developed after observing a repetitive pattern in the seismic swarm episodes occurring between July and November 2011 at El Hierro (Canary Islands). From then on, this methodology has been applied to the consecutive seismic crises registered at El Hierro, achieving a high success rate in the real-time forecasting, within 10-day time windows, of volcano-tectonic earthquakes.

  10. Speech-evoked brainstem frequency-following responses during verbal transformations due to word repetition.

    PubMed

    Galbraith, G C; Jhaveri, S P; Kuo, J

    1997-01-01

    Speech-evoked brainstem frequency-following responses (FFRs) were recorded to repeated presentations of the same stimulus word. Word repetition results in illusory verbal transformations (VTs) in which word perceptions can differ markedly from the actual stimulus. Previous behavioral studies support an explanation of VTs based on changes in arousal or attention. Horizontal and vertical dipole FFRs were recorded to assess responses with putative origins in the auditory nerve and central brainstem, respectively. FFRs were recorded from 18 subjects when they correctly heard the stimulus and when they reported VTs. Although horizontal and vertical dipole FFRs showed different frequency response patterns, dipoles did not differentiate between perceptual conditions. However, when subjects were divided into low- and high-VT groups (based on percentage of VT trials), a significant Condition x Group interaction resulted. This interaction showed the largest difference in FFR amplitudes during VT trials, with the low-VT group showing increased amplitudes, and the high-VT group showing decreased amplitudes, relative to trials in which the stimulus was correctly perceived. These results demonstrate measurable subject differences in the early processing of complex signals, due to possible effects of attention on the brainstem FFR. The present research shows that the FFR is useful in understanding human language as it is coded and processed in the brainstem auditory pathway.

  11. Variable Temperature Nuclear Magnetic Resonance and Magnetic Resonance Imaging System as a Novel Technique for In Situ Monitoring of Food Phase Transition.

    PubMed

    Song, Yukun; Cheng, Shasha; Wang, Huihui; Zhu, Bei-Wei; Zhou, Dayong; Yang, Peiqiang; Tan, Mingqian

    2018-01-24

    A nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) system with a 45 mm variable temperature (VT) sample probe (VT-NMR-MRI) was developed as an innovative technique for in situ monitoring of food phase transition. The system was designed to allow for dual deployment in either a freezing (-37 °C) or high temperature (150 °C) environment. The major breakthrough of the developed VT-NMR-MRI system is that it is able to measure the water states simultaneously in situ during food processing. The performance of the VT-NMR-MRI system was evaluated by measuring the phase transition for salmon flesh and hen egg samples. The NMR relaxometry results demonstrated that the freezing point of salmon flesh was -8.08 °C, and the salmon flesh denaturation temperature was 42.16 °C. The protein denaturation of egg was 70.61 °C, and the protein denaturation occurred at 24.12 min. Meanwhile, the use of MRI in phase transition of food was also investigated to gain internal structural information. All these results showed that the VT-NMR-MRI system provided an effective means for in situ monitoring of phase transition in food processing.

  12. A study of acoustic-to-articulatory inversion of speech by analysis-by-synthesis using chain matrices and the Maeda articulatory model

    PubMed Central

    Panchapagesan, Sankaran; Alwan, Abeer

    2011-01-01

    In this paper, a quantitative study of acoustic-to-articulatory inversion for vowel speech sounds by analysis-by-synthesis using the Maeda articulatory model is performed. For chain matrix calculation of vocal tract (VT) acoustics, the chain matrix derivatives with respect to area function are calculated and used in a quasi-Newton method for optimizing articulatory trajectories. The cost function includes a distance measure between natural and synthesized first three formants, and parameter regularization and continuity terms. Calibration of the Maeda model to two speakers, one male and one female, from the University of Wisconsin x-ray microbeam (XRMB) database, using a cost function, is discussed. Model adaptation includes scaling the overall VT and the pharyngeal region and modifying the outer VT outline using measured palate and pharyngeal traces. The inversion optimization is initialized by a fast search of an articulatory codebook, which was pruned using XRMB data to improve inversion results. Good agreement between estimated midsagittal VT outlines and measured XRMB tongue pellet positions was achieved for several vowels and diphthongs for the male speaker, with average pellet-VT outline distances around 0.15 cm, smooth articulatory trajectories, and less than 1% average error in the first three formants. PMID:21476670

  13. Bovine Colostral Antibody Against Verotoxin 2 Derived from Escherichia coli O157:H7: Resistance to Proteases and Effects in Beagle Dogs

    PubMed Central

    Kuribayashi, Takashi; Seita, Tetsuro; Matsumoto, Mariko; Furuhata, Katsunori; Tagata, Kazutoshi; Yamamoto, Shizuo

    2009-01-01

    A bovine colostral antibody against verotoxin (VT) 2 of Escherichia coli O157:H7 was administered orally to beagle dogs. The antibody remained in the dogs’ small intestine for at least 2 h, whereas little serum antibody remained 1.5 h after administration. Furthermore, the antibody activity of secretory IgA did not change until 2 h after administration; however, the activity of IgG and IgM antibodies decreased by approximately 60% and 40% at 2 h after administration, respectively. Seven beagle dogs inoculated with Escherichia coli O157:H7 producing VT2 were administered bovine colostral antibody or bovine colostral whey without antibody. With administration of bovine colostral whey without antibody, the amount of VT2 in feces decreased gradually after administration and increased again at 5 d after inoculation, whereas bovine colostral antibody significantly reduced the amount of VT2 in feces on the day after administration. In addition, 9 beagle dogs were given bovine colostral antibody, bovine plasma antibody, or saline. The amount of VT2 in feces again decreased significantly more rapidly after administration of bovine colostral antibody than after administration of bovine plasma antibody or saline. PMID:19389308

  14. In-flight automated external defibrillator use and consultation patterns.

    PubMed

    Brown, Aaron Michael; Rittenberger, Jon C; Ammon, Charles M; Harrington, Scott; Guyette, Francis X

    2010-01-01

    Limited information exists about the in-flight use and outcomes associated with automated external defibrillators (AEDs) on commercial airlines. To describe the characteristics and outcomes of AED use during in-flight emergencies including in-flight cardiac arrest and the associated ground medical consultation patterns. We collected cases of AED use that were self-reported to an airline consultation service from three U.S. airlines between May 2004 and March 2009. We reviewed all available data files, related consultation forms, and recordings. For each case, demographics, initial rhythm, shock delivery/success, survival to admission, and ground medical consultation use were obtained. Success was defined as the return of a perfusing rhythm. Initial rhythms were classified as sinus, heart block, supraventricular tachycardia (SVT), atrial fibrillation/flutter, asystole, pulseless electrical activity (PEA), and ventricular fibrillation (VF)/ventricular tachycardia (VT). There were a total of 169 AED applications with 40 cardiac arrests. The mean patient ages were 58 years (standard deviation [SD] 15) and 63 years (SD 12), respectively; both populations were 64% male. AEDs were applied for monitoring in 129 (76%) cases with the following initial rhythms: sinus, 114 (88%); atrial fibrillation/flutter, seven (5%); complete heart block, four (3%); and SVT, four (3%). Presenting rhythms among the cardiac arrest population were as follows: asystole, 16 (40%); VF/VT, 10 (25%); and PEA, 14 (35%). Fourteen patients were defibrillated, including nine of the 10 patients with initial VF/VT and five for the presence of VF/VT after resuscitation for initial PEA/asystole. Defibrillation was advised but not performed in the remaining case of initial VF/VT, and no medical consultation was obtained. All five successful defibrillations occurred in patients with initial VF/VT. There were six (15%; 95% confidence interval [CI] 3-27%) survivors, with five survivals occurring after successful defibrillation for initial VF/VT and one with return of a perfusing rhythm after cardiopulmonary resuscitation (CPR) for a junctional rhythm. Survival in those with VF/VT was five of 10 (50%; 95% CI 14-86%). Medications were delivered in two cases. The median time to first shock was 19 seconds (interquartile range [IQR] 12-24 seconds) after AED application. Medical consultation was obtained in 42 (33%) of the 129 AED monitoring cases and 14 (35%) of the 40 cardiac arrest cases. Use of AEDs resulted in 50% survival among those with VF/VT in flight and 15% overall survival for cardiac arrest. Survival is poor among patients presenting with nonshockable rhythms. AEDs are used extensively for in-flight monitoring, with significant rhythms identified. Ground medical consultation is sought in only one-third of AED uses and cardiac arrests.

  15. Variation of the distribution of crack lengths during corrosion fatigue

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ishihara, S.; Miyao, K.; Shiozawa, K.

    1984-07-01

    The detailed initiation and growth behaviour of distributed cracks on a specimen surface was investigated during corrosion fatigue. It can be clarified that the changes of the distribution of crack lengths with stress cycling reflect the behaviour of initiation and growth of distributed cracks. The distribution of crack lengths for certain stress cycles could be explained by a statistical calculation which takes into account both the variation of number of cracks during stress cycling and the scatter of crack growth rate.

  16. Land use and flow regime effects on phosphorus chemical dynamics in the fluvial sediment of the Winooski River, Vermont

    USGS Publications Warehouse

    McDowell, R.W.; Sharpley, A.N.; Chalmers, A.T.

    2002-01-01

    In the last century, fourfold increase in phosphorus (P) loadings to Lake Champlain, Vermont (VT), USA, have led to nuisance levels of algal growth occurring more often. To better understand the transport, storage, and cycling of P within the lake's catchment, we examined the chemistry, bioavailability and processes controlling sediment P release to waters of the Winooski River, VT, the largest tributary to Lake Champlain. Iron-oxide strip P (algal-bioavailable P) of the river sediments adjacent to agricultural land (3.6 mg kg-1) was greater (P < 0.05) than adjacent to forested land (2.4 mg kg-1). When compared among flow regimes, impoundment (731 mg kg-1) and reservoir sediments (803 mg kg-1) had greater total P concentrations than river sediment (462 mg kg-1). This was attributed to more fines (< 63 ??m) in impoundments and reservoirs (64%) than in river sediments (33%), which also decreased the ability of impoundment sediments to release P to solution and thereby be a sink for P. Although land use and flow regime influenced whether Winooski River sediments acted as a sink or source of P to Lake Champlain, long-term remedial strategies for the catchment should continue to focus on decreasing P losses in agricultural and urban runoff. ?? 2002 Elsevier Science B.V. All rights reserved.

  17. Reconfigurable ultra-thin film GDNMOS device for ESD protection in 28 nm FD-SOI technology

    NASA Astrophysics Data System (ADS)

    Athanasiou, Sotirios; Legrand, Charles-Alexandre; Cristoloveanu, Sorin; Galy, Philippe

    2017-02-01

    We propose a novel ESD protection device (GDNMOS: Gated Diode merged NMOS) fabricated with 28 nm UTBB FD-SOI high-k metal gate technology. By modifying the combination of the diode and transistor gate stacks, the robustness of the device is optimized, achieving a maximum breakdown voltage (VBR) of 4.9 V. In addition, modifications of the gate length modulate the trigger voltage (Vt1) with a minimum value of 3.5 V. Variable electrostatic doping (gate-induced) in diode and transistor body enables reconfigurable operation. A lower doping of the base enhances the bipolar gain, leading to thyristor behavior. This innovative architecture demonstrates excellent capability for high-voltage protection while maintaining a latch-up free behavior.

  18. 77 FR 39559 - Vermont Disaster #VT-00025

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-03

    ... SMALL BUSINESS ADMINISTRATION [Disaster Declaration 13097 and 13098] Vermont Disaster VT-00025 AGENCY: U.S. Small Business Administration. ACTION: Notice. SUMMARY: This is a Notice of the Presidential... INFORMATION CONTACT: A. Escobar, Office of Disaster Assistance, U.S. Small Business Administration, 409 3rd...

  19. The EPA Liver Project

    EPA Science Inventory

    The v-Liver is part of a broader EPA effort on Virtual Tissues (VT) aimed at reducing the magnitude and spectrum of animal testing by integrative in silico and in vitro models, which recapitulate the properties of intact organs. The other VT projects include the Virtual Embryo (...

  20. 76 FR 59479 - Vermont Disaster Number VT-00022

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-26

    ... SMALL BUSINESS ADMINISTRATION [Disaster Declaration 12786 and 12787] Vermont Disaster Number VT-00022 AGENCY: U.S. Small Business Administration. ACTION: Amendment 3. SUMMARY: This is an amendment of... remains unchanged. (Catalog of Federal Domestic Assistance Numbers 59002 and 59008) James E. Rivera...

  1. Cardiorespiratory responses of a dance session designed for older women: A cross sectional study.

    PubMed

    Rodrigues-Krause, Josianne; Farinha, Juliano Boufleur; Ramis, Thiago Rozales; Boeno, Francesco Pinto; Dos Santos, Gabriela Cristina; Krause, Mauricio; Reischak-Oliveira, Alvaro

    2018-06-04

    Dancing has been increasingly used as a type of exercise intervention to improve cardiovascular fitness of older people. However, it is unclear which may be the exercise intensity of the dance sessions. To describe cardiorespiratory responses of a dance session for older women, and to identify intensity zones in relation to peak oxygen consumption (VO 2 peak), first and second ventilatory thresholds (VT1 and VT2). Ten women (66 ± 5 yrs., BMI 27 ± 4) were examined on three occasions: Familiarization, maximum effort and dance sessions. Incremental treadmill test: 5 km/h, 2% slope each min, until maximum effort. Dance class (60 min): warm-up (20 min), across-the-floor (10 min), choreography (15 min), show (10 min) and cool-down (5 min). Ventilatory parameters were measured continuously (breath-by-breath). VO 2 (mL·kg -1 ·min -1 ): Maximum effort: VO 2 peak (23.3 ± 4.3), VT1 (17.2 ± 3.5) and VT2 (20.9 ± 3.4). Dancing: warm-up (12.8 ± 2.4, ~55%VO 2 peak), across-the-floor (14.2 ± 2.4 ~62%VO 2 peak), choreography (14.6 ± 3.2 ~63%VO 2 peak) and show (16.1 ± 3.3, ~69% VO 2 peak). Show was similar to VT1. Cardiorespiratory demands of a dance class for older women are at low aerobic intensity. Show was similar to VT1, indicating that a dance class may be modulated to improve aerobic fitness, at least at initial stages of training. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Response of Volume Transport through the Taiwan and Tsushima Straits to the Wind Fields in the East China Sea

    NASA Astrophysics Data System (ADS)

    Matsuno, T.; Liu, C. T.; Fukudome, K.; Chen, H. W.; Ichikawa, K.; Doong, D. J.; Senjyu, T.

    2016-02-01

    Circulation in the shelf region of the East China Sea is strongly controlled by the volume transport (VT) through the Taiwan Strait (TwS). It is well known that the VT through TwS has a significant seasonal variation, large in summer and small in winter. Based on a time series of the current field obtained by ADCP installed on a ferry boat crossing the TwS, from Keelung to Matsu Island in Taiwan, it had been investigated that the seasonal variations have a good correlation with the local wind around the TwS. The VT through the TwS had been compared with that through Tsushima Strait (TsS), and the results using the data from 2009 to 2012 were presented in the last OSM. In this study the monitoring data were extended further to 2014 and the difference of VTs between TwS and TsS was compared with wind fields and Ekman transport for not only seasonal variation but also shorter time scale variations. Ekman transport across the shelf break with time scales shorter than one month has a good correlation with the difference of VTs between TwS and TsS, that is, net transport across the shelf break of the East China Sea. The correlation is much better with VT through TwS rather than through TsS. Onshoreward net transport due to the Ekman transport may decrease the VT through TwS, which means that the VT through TwS is not only related to the local wind but also wind field over the East China Sea.

  3. Alternative body sites for heat stress measurement in milking cows under tropical conditions and their relationship to the thermal discomfort of the animals

    NASA Astrophysics Data System (ADS)

    Martello, Luciane S.; Savastano Junior, Holmer; Silva, Saulo L.; Balieiro, Júlio Cesar C.

    2010-11-01

    This study was conducted to determine the relationship among temperatures measured at different anatomical sites of the animal body and their daily pattern as indicative of the thermal stress in lactating dairy cows under tropical conditions. Environmental dry bulb (DBT) and black globe (BGT) temperatures and relative humidity (RH) were recorded. Rectal temperature (RT), respiratory frequency (RF), body surface (BST), internal base of tail (TT), vulva (VT) and auricular temperatures (AT) were collected, from 37 Black and White Holstein cows at 0700, 1300 and 1800 hours. RT showed a moderately and positive correlations with all body temperatures, ranging from 0.59 with TT to 0.64 with BST. Correlations among AT, VT and TT with RF were very similar (from 0.63 to 0.64) and were greater than those observed for RF with RT (0.55) or with BST (0.54). RF and RT were positively correlated to TT (0.63 and 0.59, respectively), AT (r = 0.63 for both) and VT ( r = 0.64 and 0.63, respectively). Positive and very high correlations were observed among AT, VT and TT (from 0.94 to 0.97) indicating good association of temperatures measured in these anatomical sites. Correlations of BST with AT and VT were positive and very similar (0.71 and 0.72, respectively) and lower with TT (0.66). The AT, TT, VT and BST presented similar patterns and follow the variations of DBT through the day. Temperatures measured at different anatomical sites of the animal body have the potential to be used as indicative of the thermal stress in lactating dairy cows.

  4. SpoVT: From Fine-Tuning Regulator in Bacillus subtilis to Essential Sporulation Protein in Bacillus cereus

    PubMed Central

    Eijlander, Robyn T.; Holsappel, Siger; de Jong, Anne; Ghosh, Abhinaba; Christie, Graham; Kuipers, Oscar P.

    2016-01-01

    Sporulation is a highly sophisticated developmental process adopted by most Bacilli as a survival strategy to withstand extreme conditions that normally do not support microbial growth. A complicated regulatory cascade, divided into various stages and taking place in two different compartments of the cell, involves a number of primary and secondary regulator proteins that drive gene expression directed toward the formation and maturation of an endospore. Such regulator proteins are highly conserved among various spore formers. Despite this conservation, both regulatory and phenotypic differences are observed between different species of spore forming bacteria. In this study, we demonstrate that deletion of the regulatory sporulation protein SpoVT results in a severe sporulation defect in Bacillus cereus, whereas this is not observed in Bacillus subtilis. Although spores are initially formed, the process is stalled at a later stage in development, followed by lysis of the forespore and the mother cell. A transcriptomic investigation of B. cereus ΔspoVT shows upregulation of genes involved in germination, potentially leading to premature lysis of prespores formed. Additionally, extreme variation in the expression of species-specific genes of unknown function was observed. Introduction of the B. subtilis SpoVT protein could partly restore the sporulation defect in the B. cereus spoVT mutant strain. The difference in phenotype is thus more than likely explained by differences in promoter targets rather than differences in mode of action of the conserved SpoVT regulator protein. This study stresses that evolutionary variances in regulon members of sporulation regulators can have profound effects on the spore developmental process and that mere protein homology is not a foolproof predictor of similar phenotypes. PMID:27790204

  5. SpoVT: From Fine-Tuning Regulator in Bacillus subtilis to Essential Sporulation Protein in Bacillus cereus.

    PubMed

    Eijlander, Robyn T; Holsappel, Siger; de Jong, Anne; Ghosh, Abhinaba; Christie, Graham; Kuipers, Oscar P

    2016-01-01

    Sporulation is a highly sophisticated developmental process adopted by most Bacilli as a survival strategy to withstand extreme conditions that normally do not support microbial growth. A complicated regulatory cascade, divided into various stages and taking place in two different compartments of the cell, involves a number of primary and secondary regulator proteins that drive gene expression directed toward the formation and maturation of an endospore. Such regulator proteins are highly conserved among various spore formers. Despite this conservation, both regulatory and phenotypic differences are observed between different species of spore forming bacteria. In this study, we demonstrate that deletion of the regulatory sporulation protein SpoVT results in a severe sporulation defect in Bacillus cereus , whereas this is not observed in Bacillus subtilis . Although spores are initially formed, the process is stalled at a later stage in development, followed by lysis of the forespore and the mother cell. A transcriptomic investigation of B. cereus Δ spoVT shows upregulation of genes involved in germination, potentially leading to premature lysis of prespores formed. Additionally, extreme variation in the expression of species-specific genes of unknown function was observed. Introduction of the B. subtilis SpoVT protein could partly restore the sporulation defect in the B. cereus spoVT mutant strain. The difference in phenotype is thus more than likely explained by differences in promoter targets rather than differences in mode of action of the conserved SpoVT regulator protein. This study stresses that evolutionary variances in regulon members of sporulation regulators can have profound effects on the spore developmental process and that mere protein homology is not a foolproof predictor of similar phenotypes.

  6. Role of high-resolution image integration to visualize left phrenic nerve and coronary arteries during epicardial ventricular tachycardia ablation.

    PubMed

    Yamashita, Seigo; Sacher, Frédéric; Mahida, Saagar; Berte, Benjamin; Lim, Han S; Komatsu, Yuki; Amraoui, Sana; Denis, Arnaud; Derval, Nicolas; Laurent, François; Montaudon, Michel; Hocini, Mélèze; Haïssaguerre, Michel; Jaïs, Pierre; Cochet, Hubert

    2015-04-01

    Epicardial ventricular tachycardia (VT) ablation is associated with risks of coronary artery (CA) and phrenic nerve (PN) injury. We investigated the role of multidetector computed tomography in visualizing CA and PN during VT ablation. Ninety-five consecutive patients (86 men; age, 57 ± 15) with VT underwent cardiac multidetector computed tomography. The PN detection rate and anatomic variability were analyzed. In 49 patients undergoing epicardial mapping, real-time multidetector computed tomographic integration was used to display CAs/PN locations in 3-dimensional mapping systems. Elimination of local abnormal ventricular activities (LAVAs) was used as ablation end point. The distribution of CAs/PN with respect to LAVA was analyzed and compared between VT etiologies. Multidetector computed tomography detected PN in 81 patients (85%). Epicardial LAVAs were observed in 44 of 49 patients (15 ischemic cardiomyopathy, 15 nonischemic cardiomyopathy, and 14 arrhythmogenic right ventricular cardiomyopathy) with a mean of 35 ± 37 LAVA points/patient. LAVAs were located within 1 cm from CAs and PN in 35 (80%) and 18 (37%) patients, respectively. The prevalence of LAVA adjacent to CAs was higher in nonischemic cardiomyopathy and arrhythmogenic right ventricular cardiomyopathy than in ischemic cardiomyopathy (100% versus 86% versus 53%; P < 0.01). The prevalence of LAVAs adjacent to PN was higher in nonischemic cardiomyopathy than in ischemic cardiomyopathy (93% versus 27%; P < 0.001). Epicardial ablation was performed in 37 patients (76%). Epicardial LAVAs could not be eliminated because of the proximity to CAs or PN in 8 patients (18%). The epicardial electrophysiological VT substrate is often close to CAs and PN in patients with nonischemic cardiomyopathy. High-resolution image integration is potentially useful to minimize risks of PN and CA injury during epicardial VT ablation. © 2015 American Heart Association, Inc.

  7. Cellular mechanism underlying hypothermia-induced ventricular tachycardia/ventricular fibrillation in the setting of early repolarization and the protective effect of quinidine, cilostazol, and milrinone.

    PubMed

    Gurabi, Zsolt; Koncz, István; Patocskai, Bence; Nesterenko, Vladislav V; Antzelevitch, Charles

    2014-02-01

    Hypothermia has been reported to induce ventricular tachycardia and fibrillation (VT/VF) in patients with early repolarization (ER) pattern. This study examines the cellular mechanisms underlying VT/VF associated with hypothermia in an experimental model of ER syndrome and examines the effectiveness of quinidine, cilostazol, and milrinone to prevent hypothermia-induced arrhythmias. Transmembrane action potentials were simultaneously recorded from 2 epicardial and 1 endocardial site of coronary-perfused canine left ventricular wedge preparations, together with a pseudo-ECG. A combination of NS5806 (3-10 μmol/L) and verapamil (1 μmol/L) was used to pharmacologically model the genetic mutations responsible for ER syndrome. Acetylcholine (3 μmol/L) was used to simulate increased parasympathetic tone, which is known to promote ER. In controls, lowering the temperature of the coronary perfusate to induce mild hypothermia (32°C-34°C) resulted in increased J-wave area on the ECG and accentuated epicardial action potential notch but no arrhythmic activity. In the setting of ER, hypothermia caused further accentuation of the epicardial action potential notch, leading to loss of the action potential dome at some sites but not others, thus creating the substrate for development of phase 2 reentry and VT/VF. Addition of the transient outward current antagonist quinidine (5 μmol/L) or the phosphodiesterase III inhibitors cilostazol (10 μmol/L) or milrinone (5 μmol/L) diminished the ER manifestations and prevented the hypothermia-induced phase 2 reentry and VT/VF. Hypothermia leads to VT/VF in the setting of ER by exaggerating repolarization abnormalities, leading to development of phase 2 reentry. Quinidine, cilostazol, and milrinone suppress the hypothermia-induced VT/VF by reversing the repolarization abnormalities.

  8. Acute and long term outcomes of catheter ablation using remote magnetic navigation for the treatment of electrical storm in patients with severe ischemic heart failure.

    PubMed

    Jin, Qi; Jacobsen, Peter Karl; Pehrson, Steen; Chen, Xu

    2015-03-15

    Catheter ablation with remote magnetic navigation (RMN) can offer some advantages compared to manual techniques. However, the relevant clinical evidence for how RMN-guided ablation affects electrical storm (ES) due to ventricular tachycardia (VT) in patients with severe ischemic heart failure (SIHF) is still limited. Forty consecutive SIHF patients (left ventricular ejection fraction, 21 ± 6.9%) presenting with ES underwent ablation using RMN. All the patients received implantable cardioverter-defibrillators (ICDs) either before or after ablation. Acute ablation success was defined as noninducibility of any sustained monophasic VT at the end of the procedure. Long-term analysis addressed VT recurrence, ICD therapies and all-cause death. ES was acutely suppressed by ablation in all patients. Acute ablation success was obtained in 32 of 40 (80%) patients. The procedure time and fluoroscopy time were 105 ± 27 min and 7.5 ± 4.8 min respectively. No major complications occurred during procedures. During a mean follow-up of 17.4 months, 19 patients (47.5%) remained free of VT recurrence. The percentage of patients receiving ICD shocks after ablation was lower than before ablation (30% vs 69%, P<0.01). The mean number of ICD shocks per individual per year was reduced from 4.3 before ablation to 1.9 after ablation (P<0.05). Ten patients died during follow-up. Acute catheter ablation with RMN is safe and effective to suppress ES in SIHF patients. RMN-guided catheter ablation can prevent VT recurrence and significantly reduce ICD shocks, suggesting that this strategy can be used as an alternative therapy for VT storm in SIHF patients with ICDs. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. Ventilation changes associated with hatching and maturation of an endothermic phenotype in the Pekin duck, Anas platyrhynchos domestica.

    PubMed

    Sirsat, Tushar S; Dzialowski, Edward M

    2016-04-15

    Precocial birds begin embryonic life with an ectothermic metabolic phenotype and rapidly develop an endothermic phenotype after hatching. Switching to a high-energy, endothermic phenotype requires high-functioning respiratory and cardiovascular systems to deliver sufficient environmental oxygen to the tissues. We measured tidal volume (VT), breathing frequency (ƒ), minute ventilation (V̇e), and whole-animal oxygen consumption (V̇o2) in response to gradual cooling from 37.5°C (externally pipped paranates, EP) or 35°C (hatchlings) to 20°C along with response to hypercapnia during developmental transition from an ectothermic, EP paranate to endothermic hatchling. To examine potential eggshell constraints on EP ventilation, we repeated these experiments in artificially hatched early and late EP paranates. Hatchlings and artificially hatched late EP paranates were able to increase V̇o2significantly in response to cooling. EP paranates had high ƒ that decreased with cooling, coupled with an unchanging low VT and did not respond to hypercapnia. Hatchlings had significantly lower ƒ and higher VT and V̇e that increased with cooling and hypercapnia. In response to artificial hatching, all ventilation values quickly reached those of hatchlings and responded to hypercapnia. The timing of artificial hatching influenced the temperature response, with only artificially hatched late EP animals, exhibiting the hatchling ventilation response to cooling. We suggest one potential constraint on ventilatory responses of EP paranates is the rigid eggshell, limiting air sac expansion during inhalation and constraining VT Upon natural or artificial hatching, the VT limitation is removed and the animal is able to increase VT, V̇e, and thus V̇o2, and exhibit an endothermic phenotype. Copyright © 2016 the American Physiological Society.

  10. Ventilation changes associated with hatching and maturation of an endothermic phenotype in the Pekin duck, Anas platyrhynchos domestica

    PubMed Central

    Sirsat, Tushar S.

    2016-01-01

    Precocial birds begin embryonic life with an ectothermic metabolic phenotype and rapidly develop an endothermic phenotype after hatching. Switching to a high-energy, endothermic phenotype requires high-functioning respiratory and cardiovascular systems to deliver sufficient environmental oxygen to the tissues. We measured tidal volume (VT), breathing frequency (ƒ), minute ventilation (V̇e), and whole-animal oxygen consumption (V̇o2) in response to gradual cooling from 37.5°C (externally pipped paranates, EP) or 35°C (hatchlings) to 20°C along with response to hypercapnia during developmental transition from an ectothermic, EP paranate to endothermic hatchling. To examine potential eggshell constraints on EP ventilation, we repeated these experiments in artificially hatched early and late EP paranates. Hatchlings and artificially hatched late EP paranates were able to increase V̇o2 significantly in response to cooling. EP paranates had high ƒ that decreased with cooling, coupled with an unchanging low VT and did not respond to hypercapnia. Hatchlings had significantly lower ƒ and higher VT and V̇e that increased with cooling and hypercapnia. In response to artificial hatching, all ventilation values quickly reached those of hatchlings and responded to hypercapnia. The timing of artificial hatching influenced the temperature response, with only artificially hatched late EP animals, exhibiting the hatchling ventilation response to cooling. We suggest one potential constraint on ventilatory responses of EP paranates is the rigid eggshell, limiting air sac expansion during inhalation and constraining VT. Upon natural or artificial hatching, the VT limitation is removed and the animal is able to increase VT, V̇e, and thus V̇o2, and exhibit an endothermic phenotype. PMID:26818053

  11. Vector tomography for reconstructing electric fields with non-zero divergence in bounded domains

    NASA Astrophysics Data System (ADS)

    Koulouri, Alexandra; Brookes, Mike; Rimpiläinen, Ville

    2017-01-01

    In vector tomography (VT), the aim is to reconstruct an unknown multi-dimensional vector field using line integral data. In the case of a 2-dimensional VT, two types of line integral data are usually required. These data correspond to integration of the parallel and perpendicular projection of the vector field along the integration lines and are called the longitudinal and transverse measurements, respectively. In most cases, however, the transverse measurements cannot be physically acquired. Therefore, the VT methods are typically used to reconstruct divergence-free (or source-free) velocity and flow fields that can be reconstructed solely from the longitudinal measurements. In this paper, we show how vector fields with non-zero divergence in a bounded domain can also be reconstructed from the longitudinal measurements without the need of explicitly evaluating the transverse measurements. To the best of our knowledge, VT has not previously been used for this purpose. In particular, we study low-frequency, time-harmonic electric fields generated by dipole sources in convex bounded domains which arise, for example, in electroencephalography (EEG) source imaging. We explain in detail the theoretical background, the derivation of the electric field inverse problem and the numerical approximation of the line integrals. We show that fields with non-zero divergence can be reconstructed from the longitudinal measurements with the help of two sparsity constraints that are constructed from the transverse measurements and the vector Laplace operator. As a comparison to EEG source imaging, we note that VT does not require mathematical modeling of the sources. By numerical simulations, we show that the pattern of the electric field can be correctly estimated using VT and the location of the source activity can be determined accurately from the reconstructed magnitudes of the field.

  12. Increased risk of ventricular tachycardia in patients with sarcoidosis during the very long term follow-up.

    PubMed

    Te, Abigail Louise D; Lin, Yenn-Jiang; Chen, Yun-Yu; Chung, Fa-Po; Chang, Shih-Lin; Lo, Li-Wei; Hu, Yu-Feng; Tuan, Ta-Chuan; Chao, Tze-Fan; Liao, Jo-Nan; Lin, Chin-Yu; Chang, Yao-Ting; Chien, Kuo-Liong; Chen, Shih-Ann

    2017-02-01

    Sarcoidosis is an important diagnostic consideration in patients with ventricular tachycardia (VT) of unknown origin. The clinical course of VT as the primary presentation in patients with sarcoidosis is mostly unknown. This study aimed to investigate the incidence of life-threatening VT and mortality during long term follow-up in patients with sarcoidosis. We analyzed the epidemiological features of sarcoidosis in Taiwan using the National Health Insurance Research Database from 2000 to 2004. Patients with sarcoidosis were identified, and healthy controls without prior histories of structural heart disease were matched with a 1:1 propensity-score to the sarcoidosis group. The risk of life-threatening VT and mortality with sarcoidosis was analyzed. A total of 2237 sarcoidosis cases were enrolled with a matching number of healthy controls, and the baseline characteristics between the two groups were similar. After a mean follow-up of 11.4±2.15years (IQR: 12, 11.3-12), the VT incidence in the sarcoidosis group was higher than in healthy controls (0.94% [85 per 100,000 person-year] in the sarcoidosis group, and 0.09% [8 per 100,000 person-year] in healthy controls). After a multivariate adjustment including the sex, age, and other comorbidities, the VT risk was still higher in the sarcoidosis group (hazard ratio: 12.7, 95% confidence interval: 2.82-56.9; P<0.001). The risk of defibrillator implantations for secondary prevention, cardiovascular death, and total mortality between the groups was equivalent. Sarcoidosis may increase the predisposition to ventricular arrhythmias with a cumulative incidence of 0.94% during a very long term follow-up of nearly 10years from initially diagnosing sarcoidosis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Electrical Substrate Elimination in 135 Consecutive Patients With Brugada Syndrome.

    PubMed

    Pappone, Carlo; Brugada, Josep; Vicedomini, Gabriele; Ciconte, Giuseppe; Manguso, Francesco; Saviano, Massimo; Vitale, Raffaele; Cuko, Amarild; Giannelli, Luigi; Calovic, Zarko; Conti, Manuel; Pozzi, Paolo; Natalizia, Andrea; Crisà, Simonetta; Borrelli, Valeria; Brugada, Ramon; Sarquella-Brugada, Georgia; Guazzi, Marco; Frigiola, Alessandro; Menicanti, Lorenzo; Santinelli, Vincenzo

    2017-05-01

    There is emerging evidence that localization and elimination of abnormal electric activity in the epicardial right ventricular outflow tract may be beneficial in patients with Brugada syndrome. A total of 135 symptomatic Brugada syndrome patients having implantable cardiac defibrillator were enrolled: 63 (group 1) having documented ventricular tachycardia (VT)/ventricular fibrillation (VF) and Brugada syndrome-related symptoms, and 72 (group 2) having inducible VT/VF without ECG documentation at the time of symptoms. About 27 patients of group 1 experienced multiple implantable cardiac defibrillator shocks for recurrent VT/VF episodes. Three-dimensional maps before and after ajmaline determined the arrhythmogenic electrophysiological substrate (AES) as characterized by prolonged fragmented ventricular potentials. Primary end point was identification and elimination of AES leading to ECG pattern normalization and VT/VF noninducibility. Extensive areas of AES were found in the right ventricle epicardium, which were wider in group 1 ( P =0.007). AES increased after ajmaline in both groups ( P <0.001) and was larger in men ( P =0.008). The increase of type-1 ST-segment elevation correlated with AES expansion ( r =0.682, P <0.001). Radiofrequency ablation eliminated AES leading to ECG normalization and VT/VF noninducibility in all patients. During a median follow-up of 10 months, the ECG remained normal even after ajmaline in all except 2 patients who underwent a repeated effective procedure for recurrent VF. In Brugada syndrome, AES is commonly located in the right ventricle epicardium and ajmaline exposes its extent and distribution, which is correlated with the degree of coved ST-elevation. AES elimination by radiofrequency ablation results in ECG normalization and VT/VF noninducibility. Substrate-based ablation is effective in potentially eliminating the arrhythmic consequences of this genetic disease. URL: https://clinicaltrials.gov. Unique identifier: NCT02641431. © 2017 American Heart Association, Inc.

  14. Effects of inspired CO2, hyperventilation, and time on VA/Q inequality in the dog

    NASA Technical Reports Server (NTRS)

    Tsukimoto, K.; Arcos, J. P.; Schaffartzik, W.; Wagner, P. D.; West, J. B.

    1992-01-01

    In a recent study by Tsukimoto et al. (J. Appl. Physiol. 68: 2488-2493, 1990), CO2 inhalation appeared to reduce the size of the high ventilation-perfusion ratio (VA/Q) mode commonly observed in anesthetized mechanically air-ventilated dogs. In that study, large tidal volumes (VT) were used during CO2 inhalation to preserve normocapnia. To separate the influences of CO2 and high VT on the VA/Q distribution in the present study, we examined the effect of inspired CO2 on the high VA/Q mode using eight mechanically ventilated dogs (4 given CO2, 4 controls). The VA/Q distribution was measured first with normal VT and then with increased VT. In the CO2 group at high VT, data were collected before, during, and after CO2 inhalation. With normal VT, there was no difference in the size of the high VA/Q mode between groups [10.5 +/- 3.5% (SE) of ventilation in the CO2 group, 11.8 +/- 5.2% in the control group]. Unexpectedly, the size of the high VA/Q mode decreased similarly in both groups over time, independently of the inspired PCO2, at a rate similar to the fall in cardiac output over time. The reduction in the high VA/Q mode together with a simultaneous increase in alveolar dead space (estimated by the difference between inert gas dead space and Fowler dead space) suggests that poorly perfused high VA/Q areas became unperfused over time. A possible mechanism is that elevated alveolar pressure and decreased cardiac output eliminate blood flow from corner vessels in nondependent high VA/Q regions.

  15. Reduced Brain Cannabinoid Receptor Availability In Schizophrenia

    PubMed Central

    Ranganathan, Mohini; Cortes, Jose; Radhakrishnan, Rajiv; Thurnauer, Halle; Planeta, Beata; Skosnik, Patrick; Gao, Hong; Labaree, David; Neumeister, Alexander; Pittman, Brian; Surti, Toral; Huang, Yiyun; Carson, Richard E.; D’Souza, Deepak Cyril

    2015-01-01

    BACKGROUND Several lines of evidence suggest the presence of abnormalities in the endocannabinoid (eCB) system in schizophrenia (SCZ). However, there are limited in vivo measures of the eCB system in SCZ. METHODS Twenty five male SCZ subjects (SCZs), 18 antipsychotic treated [SCZ-MED] and 7 antipsychotic free [SCZ-UNMED]) were compared to 18 age- matched male healthy control subjects (HCs). Subjects underwent one Positron Emission Tomography (PET) scan each with the cannabinoid receptor-1 (CB1R) selective radiotracer [11C]OMAR on the High Resolution Research Tomography (HRRT) scanner. Regional volume of distribution (VT) values were determined using kinetic modeling of PET data as a measure of CB1R availability. Group differences in mean composite [11C]OMAR VT values were compared between SCZs and HCs. Exploratory comparisons of CB1R availability within 15 brain regions were also conducted. All analyses were covaried for age and body mass index. RESULTS SCZs showed significantly (p =0.02) lower composite [11C]OMAR VT relative to HCs (~12% difference, effect size d= 0.73). [11C]OMAR VT was significantly (all ps <0.05) lower in SCZs in the amygdala, caudate, posterior cingulate cortex, hippocampus, hypothalamus and insula. Composite [11C]OMAR VT was greater in HCs> SCZ-MED>SCZ-UNMED. Furthermore, composite [11C]OMAR VT was greater in HCs> SCZ smokers (n=11) > SCZ non-smokers (n=14). CONCLUSIONS CB1R availability is lower in males SCZs compared to HCs. Furthermore, antipsychotics and tobacco use may increase CB1R availability in this population. The findings of the study provide further evidence supporting the hypothesis that alterations in the eCB system might contribute to the pathophysiology of SCZ. PMID:26432420

  16. Influence of crank length and crank width on maximal hand cycling power and cadence.

    PubMed

    Krämer, Christian; Hilker, Lutz; Böhm, Harald

    2009-07-01

    The effect of different crank lengths and crank widths on maximal hand cycling power, cadence and handle speed were determined. Crank lengths and crank widths were adapted to anthropometric data of the participants as the ratio to forward reach (FR) and shoulder breadth (SB), respectively. 25 able-bodied subjects performed maximal inertial load hand cycle ergometry using crank lengths of 19, 22.5 and 26% of FR and 72, 85 and 98% of SB. Maximum power ranged from 754 (246) W for the crank geometry short wide (crank length x crank width) to 873 (293) W for the combination long middle. Every crank length differed significantly (P < 0.05) from each other, whereas no significant effect of crank width to maximum power output was revealed. Optimal cadence decreased significantly (P < 0.001) with increasing crank length from 124.8 (0.9) rpm for the short to 107.5 (1.6) rpm for the long cranks, whereas optimal handle speed increased significantly (P < 0.001) with increasing crank length from 1.81 (0.01) m/s for the short to 2.13 (0.03) m/s for the long cranks. Crank width did neither influence optimal cadence nor optimal handle speed significantly. From the results of this study, for maximum hand cycling power, a crank length to FR ratio of 26% for a crank width to SB ratio of 85% is recommended.

  17. Effect of temperature and cycle length on microbial competition in PHB-producing sequencing batch reactor.

    PubMed

    Jiang, Yang; Marang, Leonie; Kleerebezem, Robbert; Muyzer, Gerard; van Loosdrecht, Mark C M

    2011-05-01

    The impact of temperature and cycle length on microbial competition between polyhydroxybutyrate (PHB)-producing populations enriched in feast-famine sequencing batch reactors (SBRs) was investigated at temperatures of 20 °C and 30 °C, and in a cycle length range of 1-18 h. In this study, the microbial community structure of the PHB-producing enrichments was found to be strongly dependent on temperature, but not on cycle length. Zoogloea and Plasticicumulans acidivorans dominated the SBRs operated at 20 °C and 30 °C, respectively. Both enrichments accumulated PHB more than 75% of cell dry weight. Short-term temperature change experiments revealed that P. acidivorans was more temperature sensitive as compared with Zoogloea. This is particularly true for the PHB degradation, resulting in incomplete PHB degradation in P. acidivorans at 20 °C. Incomplete PHB degradation limited biomass growth and allowed Zoogloea to outcompete P. acidivorans. The PHB content at the end of the feast phase correlated well with the cycle length at a constant solid retention time (SRT). These results suggest that to establish enrichment with the capacity to store a high fraction of PHB, the number of cycles per SRT should be minimized independent of the temperature.

  18. Vocational Training and the Territorial Context.

    ERIC Educational Resources Information Center

    Vocational Training, 1993

    1993-01-01

    This document contains nine articles about vocational training (VT) policy and the impact of decentralization and issues of territory on VT in the European Community (EC) member states. The following articles are included: "Vocational Training and Regional Policies: The Same Challenge..." (Landaburu); "Vocational Training in a…

  19. In search of superluminal quantum communications: recent experiments and possible improvements

    NASA Astrophysics Data System (ADS)

    Cocciaro, B.; Faetti, S.; Fronzoni, L.

    2013-06-01

    As shown in the famous EPR paper (Einstein, Podolsky e Rosen, 1935), Quantum Mechanics is non-local. The Bell theorem and the experiments by Aspect and many others, ruled out the possibility of explaining quantum correlations between entangled particles using local hidden variables models (except for implausible combinations of loopholes). Some authors (Bell, Eberhard, Bohm and Hiley) suggested that quantum correlations could be due to superluminal communications (tachyons) that propagate isotropically with velocity vt > c in a preferred reference frame. For finite values of vt, Quantum Mechanics and superluminal models lead to different predictions. Some years ago a Geneva group and our group did experiments on entangled photons to evidence possible discrepancies between experimental results and quantum predictions. Since no discrepancy was found, these experiments established only lower bounds for the possible tachyon velocities vt. Here we propose an improved experiment that should lead us to explore a much larger range of possible tachyon velocities Vt for any possible direction of velocity vec V of the tachyons preferred frame.

  20. The role of surgery in the treatment of post-infarction ventricular tachycardia. A 5 year experience.

    PubMed

    Martinelli, L; Goggi, C; Graffigna, A; Salerno, J A; Chimienti, M; Klersy, C; Viganò, M

    1987-01-01

    The purpose of this report is to present a 5 year experience in electrophysiologically guided surgical treatment of post-infarction ventricular tachycardia (VT) in a consecutive series of 39 patients. In every case the arrhythmia was not responsive to pluripharmacological therapy. The diagnostic steps included preoperative endocardial, intraoperative epi- and endocardial mapping, automatically carried out when possible. Surgical techniques were: classic Guiraudon's encircling endocardial ventriculotomy (EEV), partial EEV, endocardial resection (ER), cryoablation or combined procedures. The hospital mortality was of 4 patients (10%). During the follow-up period (1-68 mo), 4 patients (11%) died of cardiac non-VT related causes. Among the survivors, 90% are in sinus rhythm. The authors consider electrophysiologically guided surgery a safe and reliable method for the treatment of post-infarction VT and suggest more extensive indications. They stress the importance of automatic mapping in pleomorphic and non-sustained VT, and the necessity of tailoring the surgical technique to the characteristics of each case.

  1. Effect of hyperinflation on inspiratory function of the diaphragm.

    PubMed

    Minh, V D; Dolan, G F; Konopka, R F; Moser, K M

    1976-01-01

    The inspiratory efficiency of the diaphragm during unilateral and bilateral phrenic stimulation (UEPS and BEPS) with constant stimulus was studied in seven dogs from FRC to 120% TLC. Alveolar pressures (PAl) were recorded during relaxation, BEPS and UEPS at each lung volume in the closed respiratory system. From the PAl-lung volume curves, tidal volume (VT), and pressure developed by the diaphragm (Pmus) were derived. Results are summarized below. a) Hyperinflation impaired the inspiratory efficiency of the diaphragm which behaved as an expiratory muscle beyond the lung volume of 103.7% TLC (Vinef). b) The diaphragm during UEPS became expiratory at the same Vinef as during (BEPS. C) The VT-lung volume relationship was linear during BEPS, allowing simple quantitation of VT loss with hyperinflation and prediction of Vinef. d) With only one phrenic nerve stimulated, the functional loss is less pronounced in VT than in Pmus, as compared to BEPS, indicating that the respiratory system was more compliant during UEPS than BEPS. This compliance difference from UEPS to BEPS diminished with severe hyperinflation.

  2. Complications of ventilation tube insertion in children with and without cleft palate: a nested case-control comparison.

    PubMed

    Smillie, Ian; Robertson, Sophie; Yule, Anna; Wynne, David M; Russell, Craig J H

    2014-10-01

    Optimizing hearing in patients with cleft lip and/or palate (CLP) by early recognition and management of otitis media with effusion is essential for speech development. Some evidence has suggested higher complication rates from ventilation tube (VT) insertion in patients with CLP and has led to a trend not to treat these patients surgically. However, studies have failed to match comparison groups for age and sex. To compare complication rates from VT insertion in pediatric patients with and without CLP. The study used a nested case-control design to evaluate 60 pediatric patients with CLP who underwent VT insertion at a children's hospital. The control group of age- and sex-matched patients was selected from a database of 2943 VT insertions. All patients were administered general anesthesia and underwent VT insertion by a pediatric otorhinolaryngology (ENT) team. The primary outcomes were numbers of otorrhea complications. Secondarily, rates of attendance at an ENT clinic specifically for complications were evaluated. Finally, numbers of complications other than otorrhea were assessed but not statistically analyzed owing to the varied types and low numbers in each group. The control cohort had 151 documented cases of otorrhea compared with 121 in the CLP group (ratio 1.25:1); the difference between groups was not statistically significant (P = .52). There was no significant difference in mean ENT clinic visits per patient for complications between groups (0.80 in the CLP group, 0.78 for controls) (P = .66). Regarding complications other than otorrhea, the control group reported more than the CLP group (43 vs 25; ratio, 1.7:1). Complication rates of VT placement among patients with CLP were not higher than those among patients without CLP. Therefore, treatment with VT insertion should be administered to patients with CLP under the same guidelines as for those without CLP. Indeed, there could be an argument for a shift in practice toward more aggressive treatment of patients with CLP, who are already vulnerable to speech and social developmental delay.

  3. Cardiorespiratory Coordination in Repeated Maximal Exercise

    PubMed Central

    Garcia-Retortillo, Sergi; Javierre, Casimiro; Hristovski, Robert; Ventura, Josep L.; Balagué, Natàlia

    2017-01-01

    Increases in cardiorespiratory coordination (CRC) after training with no differences in performance and physiological variables have recently been reported using a principal component analysis approach. However, no research has yet evaluated the short-term effects of exercise on CRC. The aim of this study was to delineate the behavior of CRC under different physiological initial conditions produced by repeated maximal exercises. Fifteen participants performed 2 consecutive graded and maximal cycling tests. Test 1 was performed without any previous exercise, and Test 2 6 min after Test 1. Both tests started at 0 W and the workload was increased by 25 W/min in males and 20 W/min in females, until they were not able to maintain the prescribed cycling frequency of 70 rpm for more than 5 consecutive seconds. A principal component (PC) analysis of selected cardiovascular and cardiorespiratory variables (expired fraction of O2, expired fraction of CO2, ventilation, systolic blood pressure, diastolic blood pressure, and heart rate) was performed to evaluate the CRC defined by the number of PCs in both tests. In order to quantify the degree of coordination, the information entropy was calculated and the eigenvalues of the first PC (PC1) were compared between tests. Although no significant differences were found between the tests with respect to the performed maximal workload (Wmax), maximal oxygen consumption (VO2 max), or ventilatory threshold (VT), an increase in the number of PCs and/or a decrease of eigenvalues of PC1 (t = 2.95; p = 0.01; d = 1.08) was found in Test 2 compared to Test 1. Moreover, entropy was significantly higher (Z = 2.33; p = 0.02; d = 1.43) in the last test. In conclusion, despite the fact that no significant differences were observed in the conventionally explored maximal performance and physiological variables (Wmax, VO2 max, and VT) between tests, a reduction of CRC was observed in Test 2. These results emphasize the interest of CRC evaluation in the assessment and interpretation of cardiorespiratory exercise testing. PMID:28638349

  4. National Program for Inspection of Non-Federal Dams. Sugar Hill Dam (VT 00176), Richelieu River Basin, Town of Goshen, Addison County, Vermont. Phase I Inspection Report.

    DTIC Science & Technology

    1980-02-01

    MASS. 01373 o BURLINGTON O MONTPELIER SUGAR HIL o BENNINGTON 0 STATE OF VERMONT APPROX. SCALE IN MILES 25 SUGAR HILL DAM LOCATION MAP GORDON E...Resources Data For New Hampshire and Vermont - Water Year 1977", USGS Water-Data Report NH-VT-77-1, U.S. Geologi - 0 cal Survey, Boston, Ma., 1978...147.1 ItITIO01 OF I NOV 65 IS OBSOLIETE RIC HELIEU RIVER BASIN TO WN OF GOSHEN ADDISON COUNTY, VERMONT 0 S UGAR HILL DAM VT 00176 PHASE I INSPECTION

  5. Long-term Effect of Sodium Oxybate (Xyrem®) in Spasmodic Dysphonia with Vocal Tremor

    PubMed Central

    Simonyan, Kristina; Frucht, Steven J.

    2013-01-01

    Background Symptoms of spasmodic dysphonia (SD) are usually managed successfully with botulinum toxin injections. Vocal tremor (VT), which accompanies SD, has a poor response to this treatment. Case Report We report a case of a female with SD and VT who became symptom-free for 10 months after the intake of a single dose of sodium oxybate (Xyrem®). The long-term treatment effect correlated with attenuated brain activity in the key regions of dystonic brain network. Discussion Our case demonstrates that the novel treatment of sodium oxybate may hold promise for SD patients, especially those who have associated VT. PMID:24386608

  6. 77 FR 75596 - Proposed Amendment of Class E Airspace; Morrisville, VT

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-21

    ...: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed rulemaking (NPRM). SUMMARY: This action proposes to amend Class E Airspace at Morrisville, VT, as the Morrisville-Stowe Non-Directional... developed at Morrisville-Stowe State Airport. This action would enhance the safety and airspace management...

  7. 78 FR 71675 - License Amendment Application for Vermont Yankee Nuclear Power Station

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-29

    ... Vermont Yankee Nuclear Power Station AGENCY: Nuclear Regulatory Commission. ACTION: License amendment... Vermont Yankee Nuclear Power Station, located in Windham County, VT. The proposed amendment would have... Vermont Yankee Nuclear Power Station, located in Windham County, VT. The proposed amendment would have...

  8. The Effect of Limited Diffusion and Wet-Dry Cycling on Reversible Polymerization Reactions: Implications for Prebiotic Synthesis of Nucleic Acids.

    PubMed

    Higgs, Paul G

    2016-06-08

    A long-standing problem for the origins of life is that polymerization of many biopolymers, including nucleic acids and peptides, is thermodynamically unfavourable in aqueous solution. If bond making and breaking is reversible, monomers and very short oligomers predominate. Recent experiments have shown that wetting and drying cycles can overcome this problem and drive the formation of longer polymers. In the dry phase, bond formation is favourable, but diffusion is restricted, and bonds only form between monomers that are initially close together. In the wet phase, some of the bonds are hydrolyzed. However, repositioning of the molecules allows new bonds to form in the next dry phase, leading to an increase in mean polymer length. Here, we consider a simple theoretical model that explains the effect of cycling. There is an equilibrium length distribution with a high mean length that could be achieved if diffusion occurred freely in the dry phase. This equilibrium is inaccessible without diffusion. A single dry cycle without diffusion leads to mean lengths much shorter than this. Repeated cycling leads to a significant increase in polymerization relative to a single cycle. In the most favourable case, cycling leads to the same equilibrium length distribution as would be achieved if free diffusion were possible in the dry phase. These results support the RNA World scenario by explaining a potential route to synthesis of long RNAs; however, they also imply that cycling would be beneficial to the synthesis of other kinds of polymers, including peptides, where bond formation involves a condensation reaction.

  9. The Effect of Limited Diffusion and Wet–Dry Cycling on Reversible Polymerization Reactions: Implications for Prebiotic Synthesis of Nucleic Acids

    PubMed Central

    Higgs, Paul G.

    2016-01-01

    A long-standing problem for the origins of life is that polymerization of many biopolymers, including nucleic acids and peptides, is thermodynamically unfavourable in aqueous solution. If bond making and breaking is reversible, monomers and very short oligomers predominate. Recent experiments have shown that wetting and drying cycles can overcome this problem and drive the formation of longer polymers. In the dry phase, bond formation is favourable, but diffusion is restricted, and bonds only form between monomers that are initially close together. In the wet phase, some of the bonds are hydrolyzed. However, repositioning of the molecules allows new bonds to form in the next dry phase, leading to an increase in mean polymer length. Here, we consider a simple theoretical model that explains the effect of cycling. There is an equilibrium length distribution with a high mean length that could be achieved if diffusion occurred freely in the dry phase. This equilibrium is inaccessible without diffusion. A single dry cycle without diffusion leads to mean lengths much shorter than this. Repeated cycling leads to a significant increase in polymerization relative to a single cycle. In the most favourable case, cycling leads to the same equilibrium length distribution as would be achieved if free diffusion were possible in the dry phase. These results support the RNA World scenario by explaining a potential route to synthesis of long RNAs; however, they also imply that cycling would be beneficial to the synthesis of other kinds of polymers, including peptides, where bond formation involves a condensation reaction. PMID:27338479

  10. Volume guarantee ventilation during surgical closure of patent ductus arteriosus.

    PubMed

    Keszler, Martin; Abubakar, Kabir

    2015-01-01

    Surgical closure of patent ductus arteriosus (PDA) is associated with adverse outcomes. Surgical exposure requires retraction of the lung, resulting in decreased aeration and compliance. Optimal respiratory support for PDA surgery is unknown. Experience with volume guarantee (VG) ventilation at our institution led us to hypothesize that surgery would be better tolerated with automatic adjustment of pressure by VG to maintain tidal volume (VT) during retraction. The objective of this study was to describe ventilator support, VT, and oxygenation of infants supported with VG during PDA surgery. Ventilator variables, oxygen saturation, and heart rate were recorded during PDA surgery in a convenience sample of infants during PDA closure on VG. Pressure limit increased 11% and set VT was 26% lower during lung retraction. Fentanyl and pancuronium/vecuronium were used for anesthesia/muscle relaxation. Longitudinal data were analyzed by analysis of variance for repeated measures. Seven infants, 25.4 ± 1.5 weeks and 723 ± 141 g, underwent closure of PDA on VG at a mean age 29.9 days. No air leak, bradycardia, or death occurred. Target VT was maintained with a modest increase in inflation pressure. Oxygenation remained adequate. VG avoided hypoxemia and maintained adequate VT with only a modest increase in peak inflation pressure and thus may be a useful mode during PDA surgery. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  11. Ventilation tube treatment: a systematic review of the literature.

    PubMed

    Hellström, Sten; Groth, Anita; Jörgensen, Finn; Pettersson, Agneta; Ryding, Marie; Uhlén, Inger; Boström, Kristina Bengtsson

    2011-09-01

    The aim of this review was to study the effectiveness of ventilation tube (VT) treatment in children with secretory otitis media (SOM), assessed by improved hearing, normalized language and quality of life (QoL), and recurrent acute otitis media (rAOM), assessed by number of episodes of AOM and QoL. Data Sources. Cochrane Library, PubMed, and Embase databases were searched for randomized and nonrandomized controlled trials and cohort studies in English, Scandinavian, German, and French languages between 1966 and April 2007. Additional literature was retrieved from reference lists in the articles. A total of 493 abstracts were evaluated independently by 2 members of the project group, 247 full-text versions were assessed for inclusion criteria and quality using structured evaluation forms, and 63 articles were included in the review. This review shows that there is strong scientific evidence (grade 1) that VT treatment of SOM improves hearing for at least 9 months and that QoL is improved for up to 9 months (grade 2 scientific evidence). There was insufficient evidence to support an effect of VT treatment for rAOM. There was also insufficient evidence to determine whether the design or material of the VT or the procedure used for insertion had any influence on the effect; however, there was some evidence (grade 3) that aspiration of secretion at insertion does not prolong VT treatment. Further research is needed to address these issues.

  12. Feasibility of a novel remote daily monitoring system for age-related macular degeneration using mobile handheld devices: results of a pilot study.

    PubMed

    Kaiser, Peter K; Wang, Yi-Zhong; He, Yu-Guang; Weisberger, Annemarie; Wolf, Stephane; Smith, Craig H

    2013-10-01

    This pilot study evaluated the feasibility of the Health Management Tool (HMT), a novel computing system using mobile handheld devices, to remotely monitor retinal visual function daily in patients with neovascular age-related macular degeneration treated with ranibizumab. Patients with neovascular age-related macular degeneration in at least 1 eye (newly diagnosed or successfully treated < 1 year) and eligible for ranibizumab therapy were enrolled in this 16-week, prospective, open-label, single-arm study. Patients performed a shape discrimination hyperacuity test (myVisionTrack [mVT]) daily on the HMT device (iPhone 3GS) remotely and at all clinic visits. Data entered into HMT devices were collected in the HMT database, which also sent reminders for patients to take mVT. Among 160 patients from 24 U.S. centers enrolled in the study (103 [64%] ≥ 75 years of age), 84.7% on average complied with daily mVT testing and ≈ 98.9% complied with at least weekly mVT testing. The HMT database successfully uploaded more than 17,000 mVT assessment values and sent more than 9,000 reminders. Elderly patients with neovascular age-related macular degeneration were willing and able to comply with daily self-testing of retinal visual function using mobile handheld devices in this novel system of remote vision monitoring.

  13. Non-RVD mutations that enhance the dynamics of the TAL repeat array along the superhelical axis improve TALEN genome editing efficacy

    PubMed Central

    Tochio, Naoya; Umehara, Kohei; Uewaki, Jun-ichi; Flechsig, Holger; Kondo, Masaharu; Dewa, Takehisa; Sakuma, Tetsushi; Yamamoto, Takashi; Saitoh, Takashi; Togashi, Yuichi; Tate, Shin-ichi

    2016-01-01

    Transcription activator-like effector (TALE) nuclease (TALEN) is widely used as a tool in genome editing. The DNA binding part of TALEN consists of a tandem array of TAL-repeats that form a right-handed superhelix. Each TAL-repeat recognises a specific base by the repeat variable diresidue (RVD) at positions 12 and 13. TALEN comprising the TAL-repeats with periodic mutations to residues at positions 4 and 32 (non-RVD sites) in each repeat (VT-TALE) exhibits increased efficacy in genome editing compared with a counterpart without the mutations (CT-TALE). The molecular basis for the elevated efficacy is unknown. In this report, comparison of the physicochemical properties between CT- and VT-TALEs revealed that VT-TALE has a larger amplitude motion along the superhelical axis (superhelical motion) compared with CT-TALE. The greater superhelical motion in VT-TALE enabled more TAL-repeats to engage in the target sequence recognition compared with CT-TALE. The extended sequence recognition by the TAL-repeats improves site specificity with limiting the spatial distribution of FokI domains to facilitate their dimerization at the desired site. Molecular dynamics simulations revealed that the non-RVD mutations alter inter-repeat hydrogen bonding to amplify the superhelical motion of VT-TALE. The TALEN activity is associated with the inter-repeat hydrogen bonding among the TAL repeats. PMID:27883072

  14. Spatiotemporal measurement of translational and vibrational temperatures after pulsed corona discharge using laser spectroscopy

    NASA Astrophysics Data System (ADS)

    Ono, Ryo; Teramoto, Yoshiyuki; Nakagawa, Yusuke; Komuro, Atsushi; Oda, Tetsuji

    2011-10-01

    Translational and vibrational temperatures are measured in pulsed corona discharge using spatiotemporally resolved laser-induced fluorescence (LIF) and coherent anti-Stokes Raman scattering (CARS). The discharge occurs in a 13-mm point-to-plane gap with pulsed voltage of approximately 30 kV. Immediately after the discharge pulse, the vibrational temperatures of N2(v) and O2(v), Tv, are much higher than the translational temperature, Tt. Then, after the discharge pulse, Tv decreases with time, and the energy released from the vibrational relaxation increases Tt. This vibration-to-translation (V-T) energy transfer is observed; Tv and Tt change by hundreds to a thousand K after the discharge pulse with time constants of 1 us to 1 ms. It is shown that the V-T rate is remarkably increased when the ambient air is humidified. It is caused by extremely rapid V-T process of H2O-H2O system. In addition, V-T acceleration of O2(v) by O atoms due to rapid V-T rate of O2(v)-O system is also measured. The spatial profile of Tv shows that Tv decreases with increasing distance from the tip of needle electrode. It indicates that Tv, and the resulting Tt, are higher in the secondary streamer channel than in the primary streamer channel.

  15. Crack Initiation and Growth Behavior at Corrosion Pit in 2024-T3 Aluminum Alloy

    DTIC Science & Technology

    2014-09-01

    63 Figure B.1: The crack length vs. number of cycles during fatigue testing for the 2AI-01 specimen...number of cycles during fatigue testing for the the 2AI- 02 specimen...64 Figure B.3: The crack length vs. number of cycles during fatigue testing for the 2Sl-01 specimen

  16. AM CAS - Spectral variations during the eruption cycles

    NASA Astrophysics Data System (ADS)

    Richter, G. A.; Notni, P.; Tiersch, H.

    Spectroscopic investigations of AM Cas, the Z Camelopardalis star with the shortest known mean cycle length, were performed during quiescence and eruption. It is shown that, although the cycle length is very small, the spectral behavior of AM Cas during an eruption cycle is similar to that of other Z Camelopardalis stars and other U Geminorum stars. During an outburst, the Balmer emissions are narrower and the Balmer decrement is steeper than during quiescence.

  17. Central effect of vasotocin 4 receptor (VT4R/V1aR) antagonists on the stress response and food intake in chicks given neuropeptide Y (NPY).

    PubMed

    Kuenzel, Wayne J; Hancock, Megan; Nagarajan, Gurueswar; Aman, N Alphonse; Kang, Seong W

    2016-05-04

    Previous studies identified SR-49059 as a most effective antagonist of the avian vasotocin 4 receptor (VT4R) compared to other candidate blockers including the Manning compound using in silico 3 dimensional (3D) modeling/docking analysis of the chicken VT4R and an in vitro anterior pituitary cell culture study. The present experiments were designed to validate whether SR-49059 and the Manning compound would likewise be effective in vivo in blocking the VT4R when applied intracerebroventricularly (ICV) to chicks. Two treatments were tested, a stressor (immobilization) and administration of neuropeptide Y (NPY), a potent orexigenic compound. In the first experiment, birds were given the Manning compound, SR-49059 or physiological saline ICV followed by immobilization stress. Blood samples were taken and corticosterone (CORT) was determined by radioimmunoassay. It was hypothesized that both antagonists would reduce the stress response. A second experiment examined the role of the VT4R in food intake regulation. The Manning compound, SR-49059 or physiological saline was administered prior to NPY and food intake was monitored for 1h. It was hypothesized that each of the two antagonists coupled with NPY would augment food intake above the intake resulting from saline plus NPY administration. Related to the second experiment was a third that examined the difference between the effect of central administration of NPY versus SR-49059 in releasing CORT. Results of the first study showed that the Manning compound or SR-49059 prior to stress decreased CORT levels compared to controls while the second experiment showed that SR-49059 or the Manning compound plus NPY, enhanced food intake above that of the experimental group given saline and NPY. The last study showed that NPY increased plasma CORT above birds given SR-49059 centrally or saline administered controls. Taken together, results suggest that the avian VT4R is involved in the central neuroendocrine stress response as well as functions in appetite regulation by mediating an anorexigenic effect similar to what has been reported in mammals for the V1aR. In conclusion, similar to the past in silico and in vitro tests, the current in vivo experiments showed SR-49059 to be a most efficacious avian vasotocin receptor antagonist. Therefore based upon results of functional tests utilizing a highly specific mammalian antagonist, SR-49059, to the mammalian V1aR that likewise was most effective in blocking the avian VT4R and past reported high sequence homology between the mammalian V1aR and the VT4R, it is recommended that the chicken VT4R be renamed the avian V1aR to facilitate better communication among scientists involved in comparative studies. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Chemical Reactions in Turbulent Mixing Flows.

    DTIC Science & Technology

    1987-06-01

    longer in the z-t diagrams for higher fuel flow rates (consistent with longer flame lengths ) and, further, the celerity of a structure at a given axial...clocking rate synchronized with the cycle, while the slower clocking rate data corres- pond to about seven cycles. Flame lengths [61, Z,,D, for various...heat fABlLE I releases studied here are also shown in Table I Flame Lengths and Axial Measurement Stations, These flame lengths are based on 50% intermit

  19. Cell cycle phases in the unequal mother/daughter cell cycles of Saccharomyces cerevisiae.

    PubMed

    Brewer, B J; Chlebowicz-Sledziewska, E; Fangman, W L

    1984-11-01

    During cell division in the yeast Saccharomyces cerevisiae mother cells produce buds (daughter cells) which are smaller and have longer cell cycles. We performed experiments to compare the lengths of cell cycle phases in mothers and daughters. As anticipated from earlier indirect observations, the longer cell cycle time of daughter cells is accounted for by a longer G1 interval. The S-phase and the G2-phase are of the same duration in mother and daughter cells. An analysis of five isogenic strains shows that cell cycle phase lengths are independent of cell ploidy and mating type.

  20. Vocational Education and Training in Denmark. First Edition.

    ERIC Educational Resources Information Center

    Nielsen, Soren P.

    This monograph examines vocational education and training (VT) in Denmark. Section 1 presents background information/framework data on the following: Denmark's political and administrative structure; population, employment, and unemployment; and the Danish economy. In section 2, the history of VT in Denmark is traced from before 1870 to the…

  1. Survey of Employers.

    ERIC Educational Resources Information Center

    European Social Fund, Dublin (Ireland).

    A study examined attitudes of Irish employers toward vocational training (VT) activities, state agencies responsible for administering VT, and the skills that employees would need in the future. Of a sample of 500 firms that were selected as being representative from the standpoints of size, sector, location, and form of ownership, 219 were…

  2. 46 CFR 164.023-5 - Performance; standard thread.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... specification Material Type Class Ticket No. or size range V-T-285E Polyester I or II 1 E, F, FF. V-T-295E Nylon I or II A E, F, FF. MIL-T-43624A Polyester 24 through 12. MIL-T-43548C Polyester covered only 24...

  3. 46 CFR 164.023-5 - Performance; standard thread.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... specification Material Type Class Ticket No. or size range V-T-285E Polyester I or II 1 E, F, FF. V-T-295E Nylon I or II A E, F, FF. MIL-T-43624A Polyester 24 through 12. MIL-T-43548C Polyester covered only 24...

  4. Towards Extended Vantage Theory

    ERIC Educational Resources Information Center

    Glaz, Adam

    2010-01-01

    The applicability of Vantage Theory (VT), a model of (colour) categorization, to linguistic data largely depends on the modifications and adaptations of the model for the purpose. An attempt to do so proposed here, called Extended Vantage Theory (EVT), slightly reformulates the VT conception of vantage by capitalizing on some of the entailments of…

  5. Current Vocational Training in Latin America.

    ERIC Educational Resources Information Center

    Alexim, Joao Carlos

    Vocational training (VT) programs in Latin America prepare workers to perform middle-level occupations or jobs. VT in Latin America is characterized by the existence of solid and autonomous national institutes linked to the logic of economic production, funded through a payroll levy grant, counting on a tripartite board, and related to ministries…

  6. Reconstructing the 11-year solar cycle length from cosmogenic radionuclides for the last 600 years

    NASA Astrophysics Data System (ADS)

    Nilsson, Emma; Adolphi, Florian; Mekhaldi, Florian; Muscheler, Raimund

    2017-04-01

    The cyclic behavior of the solar magnetic field has been known for centuries and the 11-year solar cycle is one of the most important features directly visible on the solar disc. Using sunspot records it is evident that the length of this cycle is variable. A hypothesis of an inverse relationship between the average solar activity level and the solar cycle length has been put forward (e.g. Friis-Christensen & Lassen, 1991), indicating longer solar cycles during periods of low solar activity and vice versa. So far, studies of the behavior of the 11-year solar cycle have largely been limited for the last 4 centuries where observational sunspot data are available. However, cosmogenic radionuclides, such as 10Be and 14C from ice cores and tree rings allow an assessment of the strength of the open solar magnetic field due to its shielding influence on galactic cosmic rays in the heliosphere. Similarly, very strong solar storms can leave their imprint in cosmogenic radionuclide records via solar proton-induced direct production of cosmogenic radionuclides in the Earth atmosphere. Here, we test the hypothesis of an inverse relationship between solar cycle length and the longer-term solar activity level by using cosmogenic radionuclide records as a proxy for solar activity. Our results for the last six centuries suggest significant solar cycle length variations that could exceed the range directly inferred from sunspot records. We discuss the occurrence of SPEs within the 11-year solar cycle from a radionuclide perspective, specifically the largest one known yet, at AD 774-5 (Mekhaldi et al., 2015). References: Friis-Christensen, E. & Lassen, K. Length of the solar-cycle - An indicator of solar activity closely associated with climate. Science 254, 698-700, doi:10.1126/science.254.5032.698 (1991). Mekhaldi, F., Muscheler, R., Adolphi, F., Aldahan, A., Beer, J., McConnell, J. R., Possnert, G., Sigl, M., Svensson, A., Synal, H. A., Welten, K. C. & Woodruff, T. E. Multiradionuclide evidence for the solar origin of the cosmic-ray events of AD 774/5 and 993/4. Nature Communications 6: 8, doi:10.1038/ncomms9611 (2015).

  7. Wavelength shifting of intra-cavity photons: Adiabatic wavelength tuning in rapidly wavelength-swept lasers

    PubMed Central

    Jirauschek, Christian; Huber, Robert

    2015-01-01

    We analyze the physics behind the newest generation of rapidly wavelength tunable sources for optical coherence tomography (OCT), retaining a single longitudinal cavity mode during operation without repeated build up of lasing. In this context, we theoretically investigate the currently existing concepts of rapidly wavelength-swept lasers based on tuning of the cavity length or refractive index, leading to an altered optical path length inside the resonator. Specifically, we consider vertical-cavity surface-emitting lasers (VCSELs) with microelectromechanical system (MEMS) mirrors as well as Fourier domain mode-locked (FDML) and Vernier-tuned distributed Bragg reflector (VT-DBR) lasers. Based on heuristic arguments and exact analytical solutions of Maxwell’s equations for a fundamental laser resonator model, we show that adiabatic wavelength tuning is achieved, i.e., hopping between cavity modes associated with a repeated build up of lasing is avoided, and the photon number is conserved. As a consequence, no fundamental limit exists for the wavelength tuning speed, in principle enabling wide-range wavelength sweeps at arbitrary tuning speeds with narrow instantaneous linewidth. PMID:26203373

  8. Electrophysiologic Study

    PubMed Central

    Gold, Daniel R.; Catanzaro, John N.; Makaryus, John N.; Waldman, Cory; Sauer, William H.; Sison, Cristina; Makaryus, Amgad N.; Altman, Erik; Jadonath, Ram; Beldner, Stuart

    2010-01-01

    Studies have shown the predictive value of inducible ventricular tachycardia and clinical arrhythmia in patients who have structural heart disease. We examined the possible predictive value of electrophysiologic study before the placement of an implantable cardioverter-defibrillator. Our retrospective study group comprised 315 patients who had ventricular tachycardia that was inducible during electrophysiologic study and who had undergone at least 1 month of follow-up (247 men; mean age, 66.9 ± 13.5 yr; mean follow-up, 24.9 ± 14.8 mo). Recorded characteristics included induced ventricular tachycardia cycle length, atrio-His and His-ventricular electrograms, PR and QT intervals, QRS duration, and drug therapy. Of the 315 patients, 97 experienced ventricular arrhythmia during the follow-up period, as registered by 184 of more than 400 interrogations. There were 187 episodes of ventricular arrhythmia (tachycardia, 178; fibrillation, 9) during 652.5 person-years of follow-up. Subjects with a cycle length ≥240 msec were more likely to have an earlier 1st arrhythmia than those with a cycle length <240 msec (P=0.032). A quarter of the subjects with a cycle length ≥240 msec had their 1st arrhythmia by 19.14 months, compared with 23.8 months for a quarter of the subjects with a cycle length <240 msec (P <0.032). Among the electrophysiologic characteristics examined, inducible ventricular tachycardia with a cycle length ≥240 msec is predictive of appropriate implantable cardioverter-defibrillator therapy at an earlier time. This may have prognostic implications that warrant implantable cardioverter-defibrillator programming to enable appropriate antitachycardia pacing in this group of patients. PMID:20548804

  9. Successful catheter ablation of hemodynamically unstable monomorphic ventricular tachycardia in a patient with hypertrophic cardiomyopathy and apical aneurysm.

    PubMed

    Lim, Kiam-Khiang; Maron, Barry J; Knight, Bradley P

    2009-04-01

    Patients with hypertrophic cardiomyopathy (HCM) and left ventricular (LV) apical aneurysm represent a previously under-recognized but important subgroup within this heterogeneous disease spectrum. Apical aneurysms and the contiguous areas of myocardial fibrosis have been associated with monomorphic ventricular tachycardia (VT) and increased risk for adverse clinical events including sudden cardiac death, prioritizing the application of primary prevention implantable defibrillators. However, VT may be repetitive, thereby raising considerations for additional treatment strategies such as radiofrequency ablation. In this report, we describe such a patient with HCM and apical aneurysm in whom the mapping and ablation procedure was effective in identifying and abolishing the VT focus.

  10. Arrhythmogenic Right Ventricular Cardiomyopathy with Multiple Thrombi and Ventricular Tachycardia of Atypical Left Branch Bundle Block Morphology.

    PubMed

    Gong, Shenzhen; Wei, Xin; Liu, Guyue; Wu, Feng; Chen, Xiaoping

    2018-04-06

    A 61-year-old male patient was admitted to our hospital with recurrent palpitations and syncope. Electrocardiography, echocardiography, and contrast-enhanced computed tomography were performed. The patient was diagnosed with arrhythmogenic right ventricular cardiomyopathy (ARVC) complicated by multiple thrombi, and ventricular tachycardia (VT) without typical left bundle branch block (LBBB) morphology. This case suggests that VT is not always the sole contributor to syncope and death in patients with ARVC, and pulmonary embolism should be considered. Furthermore, VT with typical LBBB morphology is not an absolute necessity as a major criterion for the diagnosis of ARVC when the right heart is extremely enlarged.

  11. Extending Depot Length and Intervals for DDG 51 Class Ships: Examining the 72 Month Operational Cycle

    DTIC Science & Technology

    2016-01-01

    tenance period to achieve planned expected service life ( ESL ), as well as the length, workload, and periodicity of a continuous maintenance...a ship’s service life but extends the length of each deployment. Figure 2.1 compares the number of deployments that can be made over the ESL of...ships in different cycle lengths. The ESL of DDG-51 Arleigh Burke–class destroyers Flight I and II is 35 years, and Flight IIA has an ESL of 40 years

  12. A factor analysis approach to examining relationships among ovarian steroid concentrations, gonadotrophin concentrations and menstrual cycle length characteristics in healthy, cycling women

    PubMed Central

    Barrett, E.S.; Thune, I.; Lipson, S.F.; Furberg, A.-S.; Ellison, P.T.

    2013-01-01

    STUDY QUESTION How are ovarian steroid concentrations, gonadotrophins and menstrual cycle characteristics inter-related within normal menstrual cycles? SUMMARY ANSWER Within cycles, measures of estradiol production are highly related to one another, as are measures of progesterone production; however, the two hormones also show some independence from one another, and measures of cycle length and gonadotrophin concentrations show even greater independence, indicating minimal integration within cycles. WHAT IS KNOWN ALREADY The menstrual cycle is typically conceptualized as a cohesive unit, with hormone levels, follicular development and ovulation all closely inter-related within a single cycle. Empirical support for this idea is limited, however, and to our knowledge, no analysis has examined the relationships among all of these components simultaneously. STUDY DESIGN, SIZE, DURATION A total of 206 healthy, cycling Norwegian women participated in a prospective cohort study (EBBA-I) over the duration of a single menstrual cycle. Of these, 192 contributed hormonal and cycle data to the current analysis. PARTICIPANTS/MATERIALS, SETTING, METHODS Subjects provided daily saliva samples throughout the menstrual cycle from which estradiol and progesterone concentrations were measured. FSH and LH concentrations were measured in serum samples from three points in the same menstrual cycle and cycle length characteristics were calculated based on hormonal data and menstrual records. A factor analysis was conducted to examine the underlying relationships among 22 variables derived from the hormonal data and menstrual cycle characteristics. MAIN RESULTS AND THE ROLE OF CHANCE Six rotated factors emerged, explaining 80% of the variance in the data. Of these, factors representing estradiol and progesterone concentrations accounted for 37 and 13% of the variance, respectively. There was some association between measures of estradiol and progesterone production within cycles; however, cycle length characteristics and gonadotrophin concentrations showed little association with any measure of ovarian hormone concentrations. LIMITATIONS, REASONS FOR CAUTION Our summary measures of ovarian hormones may be imprecise in women with extremely long or short cycles, which could affect the patterns emerging in the factor analysis. Given that we only had data from one cycle on each woman, we cannot address how cycle characteristics may covary within individual women across multiple cycles. WIDER IMPLICATIONS OF THE FINDINGS Our findings are generalizable to other healthy populations with typical cycles, however, may not be applicable to cycles that are anovulatory, extreme in length or otherwise atypical. The results support previous findings that measures of estradiol production are highly correlated across the cycle, as are measures of progesterone production. Estradiol and progesterone concentrations are associated with one another, furthermore. However factor analysis also revealed more complex underlying patterns in the menstrual cycle, highlighting the fact that gonadotrophin concentrations and cycle length characteristics are virtually independent of ovarian hormones. These results suggest that despite integration of follicular and luteal ovarian steroid production across the cycle, cycle quality is a multi-faceted construct, rather than a single dimension. STUDY FUNDING/COMPETING INTEREST(S) The EBBA-I study was supported by a grant from the Norwegian Cancer Society (49 258, 05087); Foundation for the Norwegian Health and Rehabilitation Organizations (59010-2000/2001/2002); Aakre Foundation (5695-2000, 5754-2002) and Health Region East. The current analyses were completed under funding from the National Institutes of Health (K12 ES019852). No competing interests declared. PMID:23250924

  13. Tracking Behavioral Progress within a Children's Mental Health System: The Vermont Community Adjustment Tracking System.

    ERIC Educational Resources Information Center

    Bruns, Eric J.; Burchard, John D.; Froelich, Peter; Yoe, James T.; Tighe, Theodore

    1998-01-01

    Describes the Vermont Community Adjustment Tracking System (VT-CATS), which utilizes four behavioral instruments to allow intensive, ongoing, and interpretable behavioral assessment of a service system's most challenging children and adolescents. Also explains the adjustment indicator checklists and the ability of VT-CATS to address agencies'…

  14. AUTOMOTIVE DIESEL MAINTENANCE. PROGRAM OUTLINE.

    ERIC Educational Resources Information Center

    Human Engineering Inst., Cleveland, OH.

    INFORMATIONAL TOPICS COVERED IN THE TEXT MATERIALS AND SELF-INSTRUCTIONAL BRANCH PROGRAMED TRAINING FILMS FOR A 2-YEAR, 55 MODULE PROGRAM IN AUTOMOTIVE DIESEL MAINTENANCE ARE GIVEN. THE 30 MODULES FOR "AUTOMOTIVE DIESEL MAINTENANCE 1" ARE AVAILABLE AS VT 005 655 - VT 005 684, AND THE 25 MODULES FOR "AUTOMOTIVE DIESEL MAINTENANCE 2" ARE AVAILABLE…

  15. The World of Manufacturing. Industrial Arts Curriculum Project.

    ERIC Educational Resources Information Center

    Ohio State Univ., Columbus. Research Foundation.

    This textbook for junior high school students encompasses concepts found in manufacturing, and together with a teacher's guide (VT 014 238) and laboratory manual (VT 014 239) constitutes the second part of a 2-year integrated program in industrial technology. This and the first year course in construction technology, were developed under contract…

  16. Developing Oral Proficiency with VoiceThread: Learners' Strategic Uses and Views

    ERIC Educational Resources Information Center

    Dugartsyrenova, Vera A.; Sardegna, Veronica G.

    2017-01-01

    This study explored Russian as a foreign language (RFL) learners' self-reported strategic uses of "VoiceThread" (VT)--a multimodal asynchronous computer-mediated communication tool--in order to gain insights into learner perceived effectiveness of VT for second language (L2) oral skills development and to determine the factors that…

  17. Achievement Profiles of Students in High School Vocational Training Programs

    ERIC Educational Resources Information Center

    Dubeau, Annie; Plante, Isabelle; Frenay, Mariane

    2017-01-01

    Vocational training (VT) allows young people to receive specialized training in a short period and enter the labor market with a qualification. However, VT is often seen as an unglamorous educational route, despite the fact that there are few admission requirements and that it prepares students for jobs with good conditions. Furthermore, the…

  18. 75 FR 22228 - Regulated Navigation Area; Lake Champlain Bridge Construction Zone, NY and VT

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-28

    ...-AA11 Regulated Navigation Area; Lake Champlain Bridge Construction Zone, NY and VT AGENCY: Coast Guard... establishing a regulated navigation area around the construction zone of the Lake Champlain Bridge between... on all vessels transiting the navigable waters of Lake Champlain in the vicinity of the bridge...

  19. Identification of spinal circuits involved in touch-evoked dynamic mechanical pain

    PubMed Central

    Cheng, Longzhen; Duan, Bo; Huang, Tianwen; Zhang, Yan; Chen, Yangyang; Britz, Olivier; Garcia-Campmany, Lidia; Ren, Xiangyu; Vong, Linh; Lowell, Bradford B.; Goulding, Martyn; Wang, Yun; Ma, Qiufu

    2017-01-01

    Mechanical hypersensitivity is a debilitating symptom associated with millions of chronic pain patients. It exists in distinct forms, including brush-evoked dynamic and filament-evoked punctate. Here we report that dynamic mechanical hypersensitivity induced by nerve injury or inflammation was compromised in mice with ablation of spinal VT3Lbx1 neurons defined by coexpression of VGLUT3Cre and Lbx1Flpo, as indicated by the loss of brush-evoked nocifensive responses and conditional place aversion. Electrophysiological recordings show that VT3Lbx1 neurons form morphine-resistant polysynaptic pathways relaying inputs from low-threshold Aβ mechanoreceptors to lamina I output neurons. Meanwhile, the subset of somatostatin (SOM) lineage neurons preserved in VT3Lbx1 neuron-ablated mice is largely sufficient to mediate von Frey filament-evoked punctate mechanical hypersensitivity, including both morphine-sensitive and morphine-resistant forms. Furthermore, acute silencing of VT3Lbx1 neurons attenuated pre-established dynamic mechanical hypersensitivity induced by nerve injury, suggesting these neurons as a potential cellular target for treating this form of neuropathic pain. PMID:28436981

  20. Pulmonary Gas Exchange Abnormalities in Mild Chronic Obstructive Pulmonary Disease. Implications for Dyspnea and Exercise Intolerance.

    PubMed

    Elbehairy, Amany F; Ciavaglia, Casey E; Webb, Katherine A; Guenette, Jordan A; Jensen, Dennis; Mourad, Sahar M; Neder, J Alberto; O'Donnell, Denis E

    2015-06-15

    Several studies in mild chronic obstructive pulmonary disease (COPD) have shown a higher than normal ventilatory equivalent for carbon dioxide ([Formula: see text]e/[Formula: see text]co2) during exercise. Our objective was to examine pulmonary gas exchange abnormalities and the mechanisms of high [Formula: see text]e/[Formula: see text]co2 in mild COPD and its impact on dyspnea and exercise intolerance. Twenty-two subjects (11 patients with GOLD [Global Initiative for Chronic Obstructive Lung Disease] grade 1B COPD, 11 age-matched healthy control subjects) undertook physiological testing and a symptom-limited incremental cycle exercise test with arterial blood gas collection. Patients (post-bronchodilator FEV1: 94 ± 10% predicted; mean ± SD) had evidence of peripheral airway dysfunction and reduced peak oxygen uptake compared with control subjects (80 ± 18 vs. 113 ± 24% predicted; P<0.05). Arterial blood gases were within the normal range and effective alveolar ventilation was not significantly different from control subjects throughout exercise. The alveolar-arterial O2 tension gradient was elevated at rest and throughout exercise in COPD (P<0.05). [Formula: see text]e/[Formula: see text]co2, dead space to tidal volume ratio (Vd/Vt), and arterial to end-tidal CO2 difference were all higher (P<0.05) in patients with COPD than in control subjects during exercise. In patients with COPD versus control subjects, there was significant dynamic hyperinflation and greater tidal volume constraints (P<0.05). Standardized dyspnea intensity ratings were also higher (P<0.05) in patients with COPD versus control subjects in association with higher ventilatory requirements. Within all subjects, Vd/Vt correlated with the [Formula: see text]e/[Formula: see text]co2 ratio during submaximal exercise (r=0.780, P<0.001). High Vd/Vt was the most consistent gas exchange abnormality in smokers with only mild spirometric abnormalities. Compensatory increases in minute ventilation during exercise maintained alveolar ventilation and arterial blood gas homeostasis but at the expense of earlier dynamic mechanical constraints, greater dyspnea, and exercise intolerance in mild COPD.

  1. Noninvasive method to estimate anaerobic threshold in individuals with type 2 diabetes.

    PubMed

    Sales, Marcelo M; Campbell, Carmen Sílvia G; Morais, Pâmella K; Ernesto, Carlos; Soares-Caldeira, Lúcio F; Russo, Paulo; Motta, Daisy F; Moreira, Sérgio R; Nakamura, Fábio Y; Simões, Herbert G

    2011-01-12

    While several studies have identified the anaerobic threshold (AT) through the responses of blood lactate, ventilation and blood glucose others have suggested the response of the heart rate variability (HRV) as a method to identify the AT in young healthy individuals. However, the validity of HRV in estimating the lactate threshold (LT) and ventilatory threshold (VT) for individuals with type 2 diabetes (T2D) has not been investigated yet. To analyze the possibility of identifying the heart rate variability threshold (HRVT) by considering the responses of parasympathetic indicators during incremental exercise test in type 2 diabetics subjects (T2D) and non diabetics individuals (ND). Nine T2D (55.6 ± 5.7 years, 83.4 ± 26.6 kg, 30.9 ± 5.2 kg.m2(-1)) and ten ND (50.8 ± 5.1 years, 76.2 ± 14.3 kg, 26.5 ± 3.8 kg.m2(-1)) underwent to an incremental exercise test (IT) on a cycle ergometer. Heart rate (HR), rate of perceived exertion (RPE), blood lactate and expired gas concentrations were measured at the end of each stage. HRVT was identified through the responses of root mean square successive difference between adjacent R-R intervals (RMSSD) and standard deviation of instantaneous beat-to-beat R-R interval variability (SD1) by considering the last 60 s of each incremental stage, and were known as HRVT by RMSSD and SD1 (HRVT-RMSSD and HRVT-SD1), respectively. No differences were observed within groups for the exercise intensities corresponding to LT, VT, HRVT-RMSSD and HHVT-SD1. Furthermore, a strong relationship were verified among the studied parameters both for T2D (r = 0.68 to 0.87) and ND (r = 0.91 to 0.98) and the Bland & Altman technique confirmed the agreement among them. The HRVT identification by the proposed autonomic indicators (SD1 and RMSSD) were demonstrated to be valid to estimate the LT and VT for both T2D and ND.

  2. The effect of chronic progressive-dose sodium bicarbonate ingestion on CrossFit-like performance: A double-blind, randomized cross-over trial.

    PubMed

    Durkalec-Michalski, Krzysztof; Zawieja, Emilia E; Podgórski, Tomasz; Łoniewski, Igor; Zawieja, Bogna E; Warzybok, Marta; Jeszka, Jan

    2018-01-01

    Sodium bicarbonate (SB) has been proposed as an ergogenic aid, as it improves high-intensity and resistance exercise performance. However, no studies have yet investigated SB application in CrossFit. This study examined the effects of chronic, progressive-dose SB ingestion on CrossFit-like performance and aerobic capacity. In a randomized, double-blind, cross-over trial, 21 CrossFit-trained participants were randomly allocated to 2 groups and underwent 2 trials separated by a 14-day washout period. Participants ingested either up to 150 mg∙kg-1 of SB in a progressive-dose regimen or placebo for 10 days. Before and after each trial, Fight Gone Bad (FGB) and incremental cycling (ICT) tests were performed. In order to examine biochemical responses, blood samples were obtained prior to and 3 min after completing each exercise test. No gastrointestinal (GI) side effects were reported during the entire protocol. The overall FGB performance improved under SB by ~6.1% (p<0.001) and it was ~3.1% higher compared to post placebo (PLApost) (p = 0.040). The number of repetitions completed in each round also improved under SB (mean from baseline: +5.8% to +6.4%). Moreover, in ICT, the time to ventilatory threshold (VT) (~8:25 min SBpost vs. ~8:00 min PLApost, p = 0.020), workload at VT (~218 W SBpost vs. ~208 W PLApost, p = 0.037) and heart rate at VT (~165 bpm SBpost vs. ~161 bpm PLApost, p = 0.030) showed higher SBpost than PLApost. Furthermore, the maximum carbon dioxide production increased under SB by ~4.8% (from ~3604 mL∙min-1 to ~3776 mL∙min-1, p = 0.049). Pyruvate concentration and creatine kinase activity before ICT showed higher SBpost than PLApost (~0.32 mmol∙L-1 vs. ~0.26 mmol∙L-1, p = 0.001; ~275 U∙L-1 vs. ~250 U∙L-1, p = 0.010, respectively). However, the small sample size limits the wide-application of our results. Progressive-dose SB ingestion regimen eliminated GI side effects and improved CrossFit-like performance, as well as delayed ventilatory threshold occurrence.

  3. Increased skin barrier disruption by sodium lauryl sulfate in mice expressing a constitutively active STAT6 in T cells.

    PubMed

    DaSilva, Sonia C; Sahu, Ravi P; Konger, Raymond L; Perkins, Susan M; Kaplan, Mark H; Travers, Jeffrey B

    2012-01-01

    Atopic dermatitis (AD) is a pruritic, chronic inflammatory skin disease that affects 10-20% of children and 1-3% of adults worldwide. Recent studies have indicated that the ability of Th2 cytokines, such as interleukin-4 (IL-4) to regulate skin barrier function may be a predisposing factor for AD development. The present studies examined the ability of increased Th2 activity to affect cutaneous barrier function in vivo and epidermal thickening. Mice that express a constitutively active Signal Transducer and Activator of Transcription 6 (STAT6VT) have increased Th2 cells and a predisposition to allergic inflammation were used in these studies, they demonstrate that topical treatment with the irritant sodium lauryl sulfate (SLS) caused increased transepidermal water loss and epidermal thickening in STAT6VT mice over similarly treated wild-type mice. The proliferation marker Ki-67 was increased in the epidermis of STAT6VT compared to the wild-type mice. However, these differences do not appear to be linked to the addition of an irritant as control-treated STAT6VT skin also exhibited elevated Ki-67 levels, suggesting that the increased epidermal thickness in SLS-treated STAT6VT mice is primarily driven by epidermal cell hypertrophy rather than an increase in cellular proliferation. Our results suggest that an environment with increased Th2 cytokines results in abnormal responses to topical irritants.

  4. Increased skin barrier disruption by sodium lauryl sulfate in mice expressing a constitutively active STAT6 in T cells

    PubMed Central

    DaSilva, Sonia C.; Sahu, Ravi P.; Konger, Raymond L.; Perkins, Susan M.; Kaplan, Mark H.; Travers, Jeffrey B.

    2011-01-01

    Atopic dermatitis (AD) is a pruritic, chronic inflammatory skin disease that affects 10–20% of children and 1–3% of adults worldwide. Recent studies have indicated that the ability of Th2 cytokines such as interleukin-4 (IL-4) to regulate skin barrier function may be a predisposing factor for AD development. The present studies examined the ability of increased Th2 activity to affect cutaneous barrier function in vivo and epidermal thickening. Mice that express a constitutively active Signal Transducer and Activator of Transcription 6 (STAT6VT) have increased Th2 cells and a predisposition to allergic inflammation were used in these studies; they demonstrate that topical treatment with the irritant sodium lauryl sulfate (SLS) caused increased transepidermal water loss and epidermal thickening in STAT6VT mice over similarly treated wild-type mice. The proliferation marker Ki-67 was increased in the epidermis of STAT6VT compared to wild-type mice. However, these differences do not appear to be linked to the addition of an irritant as control-treated STAT6VT skin also exhibited elevated Ki-67 levels, suggesting that the increased epidermal thickness in SLS-treated STAT6VT mice is primarily driven by epidermal cell hypertrophy rather than an increase in cellular proliferation. Our results suggest that an environment with increased Th2 cytokines results in abnormal responses to topical irritants. PMID:21959772

  5. Screening of Lactic Acid Bacteria for Anti-Fusarium Activity and Optimization of Incubation Conditions.

    PubMed

    Zhao, Hui; Vegi, Anuradha; Wolf-Hall, Charlene

    2017-10-01

    Anti-Fusarium activities of lactic acid bacteria (LAB) Lactobacillus plantarum 299V, L. plantarum NRRL-4496, and Lactobacillus rhamnosus VT1 were determined by a microdilution assay developed in this study against Fusarium graminearum 08/RG/BF/51. A cell-free Lactobacillus culture supernatant (CFLCS) of L. rhamnosus VT1 had the highest anti-Fusarium activity. Response surface methodology was used to optimize the incubation conditions for production of CFLCS. A Box-Behnken factorial design was used to investigate the effects of incubation time, shaking speed, and incubation temperature on the inhibition rate of CFLCS. A model equation was generated to predict the inhibition rate of CFLCS under various incubation conditions. A low probability value (0.0012) and associated F value of 25.10 suggested that the model was highly significant. A high R 2 value (0.978) indicated a very satisfactory model performance. Response surface methodology analysis suggested that an incubation temperature at 34°C, a shaking speed at 170 rpm, and an incubation time of 55 h were the best combination for production of CFLCS from L. rhamnosus VT1. Under these incubation conditions, a 10% L. rhamnosus VT1 CFLCS solution was predicted to inhibit the growth of F. graminearum by 75.6% in vitro and inhibited 83.7% of the growth in the validation experiment. Thus, the CFLCS of L. rhamnosus VT1 was an effective anti-Fusarium mixture.

  6. Influence of forward leaning and incentive spirometry on inspired volumes and inspiratory electromyographic activity during breathing exercises in healthy subjects.

    PubMed

    Santos, Thalita Vilaboim; Ruas, Gualberto; Sande de Souza, Luciane Aparecida Pascucci; Volpe, Marcia Souza

    2012-12-01

    Breathing exercises (BE), incentive spirometry and positioning are considered treatment modalities to achieve lung re-expansion. This study evaluated the influence of incentive spirometry and forward leaning on inspired tidal volumes (V(T)) and electromyographic activity of inspiratory muscles during BE. Four modalities of exercises were investigated: deep breathing, spirometry using both flow and volume-oriented devices, and volume-oriented spirometry after modified verbal instruction. Twelve healthy subjects aged 22.7 ± 2.1 years were studied. Surface electromyography activity of diaphragm, external intercostals, sternocleidomastoid and scalenes was recorded. Comparisons among the three types of exercises, without considering spirometry after modified instruction, showed that electromyographic activity and V(T) were lower during volume-oriented spirometry (p = 0.000, p = 0.054, respectively). Forward leaning resulted in a lower V(T) when compared to upright sitting (p = 0.000), but electromyographic activity was not different (p = 0.606). Inspired V(T) and electromyographic activity were higher during volume-oriented spirometry performed after modified instruction when compared with the flow-oriented device (p = 0.027, p = 0.052, respectively). In conclusion BE using volume-oriented spirometry before modified instruction resulted in a lower work of breathing as a result of a lower V(T) and was not a consequence of the device type used. Forward leaning might not be assumed by healthy subjects during situations of augmented respiratory demand. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Electrical storm in patients with an implanted defibrillator: a matter of definition.

    PubMed

    Israel, Carsten W; Barold, S Serge

    2007-10-01

    The term "electrical storm" (ES) indicates a state of cardiac electrical instability manifested by several episodes of ventricular tachyarrhythmias (VTs) within a short time. In patients with an implantable cardioverter defibrillator (ICD), ES is best defined as 3 appropriate VT detections in 24 h, treated by antitachycardia pacing, shock or eventually untreated but sustained in a VT monitoring zone. The number of shocks and inappropriate detections are irrelevant for the definition. ES occurs in approximately 25% of ICD patients within 3 years, with typically 5-55 individual VTs within one storm. Potential triggers can be found in approximately 66% of patients and include new/worsened heart failure, changes in antiarrhythmic medication, context with other illness, psychological stress, diarrhea, and hypokalemia. In most patients, ES consists of monomorphic VT indicating the presence of reentry while ventricular fibrillation indicating acute ischemia is rare. ES seems to have a low immediate mortality (1%) but frequently (50-80%) leads to hospitalization. Long-term prognostic implications of ES are unclear. The key intervention in ES is reduction of the elevated sympathetic tone by beta blockers and frequently benzodiazepines. Amiodarone i.v. has also been successful and azimilide seems promising while class I antiarrhythmic drugs are usually unsuccessful. Substrate mapping and VT ablation may be useful in treatment and prevention of ES. Prevention of ES requires ICD programming systematically avoiding unnecessary shocks (long VT detection, antitachycardia pacing where ever possible) which otherwise can fuel the sympathetic tone and prolong ES.

  8. Conopeptide Vt3.1 preferentially inhibits BK potassium channels containing β4 subunits via electrostatic interactions.

    PubMed

    Li, Min; Chang, Shan; Yang, Longjin; Shi, Jingyi; McFarland, Kelli; Yang, Xiao; Moller, Alyssa; Wang, Chunguang; Zou, Xiaoqin; Chi, Chengwu; Cui, Jianmin

    2014-02-21

    BK channel β subunits (β1-β4) modulate the function of channels formed by slo1 subunits to produce tissue-specific phenotypes. The molecular mechanism of how the homologous β subunits differentially alter BK channel functions and the role of different BK channel functions in various physiologic processes remain unclear. By studying channels expressed in Xenopus laevis oocytes, we show a novel disulfide-cross-linked dimer conopeptide, Vt3.1 that preferentially inhibits BK channels containing the β4 subunit, which is most abundantly expressed in brain and important for neuronal functions. Vt3.1 inhibits the currents by a maximum of 71%, shifts the G-V relation by 45 mV approximately half-saturation concentrations, and alters both open and closed time of single channel activities, indicating that the toxin alters voltage dependence of the channel. Vt3.1 contains basic residues and inhibits voltage-dependent activation by electrostatic interactions with acidic residues in the extracellular loops of the slo1 and β4 subunits. These results suggest a large interaction surface between the slo1 subunit of BK channels and the β4 subunit, providing structural insight into the molecular interactions between slo1 and β4 subunits. The results also suggest that Vt3.1 is an excellent tool for studying β subunit modulation of BK channels and for understanding the physiological roles of BK channels in neurophysiology.

  9. Assessment of regional ventilation distribution: comparison of vibration response imaging (VRI) with electrical impedance tomography (EIT).

    PubMed

    Shi, Chang; Boehme, Stefan; Bentley, Alexander H; Hartmann, Erik K; Klein, Klaus U; Bodenstein, Marc; Baumgardner, James E; David, Matthias; Ullrich, Roman; Markstaller, Klaus

    2014-01-01

    Vibration response imaging (VRI) is a bedside technology to monitor ventilation by detecting lung sound vibrations. It is currently unknown whether VRI is able to accurately monitor the local distribution of ventilation within the lungs. We therefore compared VRI to electrical impedance tomography (EIT), an established technique used for the assessment of regional ventilation. Simultaneous EIT and VRI measurements were performed in the healthy and injured lungs (ALI; induced by saline lavage) at different PEEP levels (0, 5, 10, 15 mbar) in nine piglets. Vibration energy amplitude (VEA) by VRI, and amplitudes of relative impedance changes (rel.ΔZ) by EIT, were evaluated in seven regions of interest (ROIs). To assess the distribution of tidal volume (VT) by VRI and EIT, absolute values were normalized to the VT obtained by simultaneous spirometry measurements. Redistribution of ventilation by ALI and PEEP was detected by VRI and EIT. The linear correlation between pooled VT by VEA and rel.ΔZ was R(2) = 0.96. Bland-Altman analysis showed a bias of -1.07±24.71 ml and limits of agreement of -49.05 to +47.36 ml. Within the different ROIs, correlations of VT-distribution by EIT and VRI ranged between R(2) values of 0.29 and 0.96. ALI and PEEP did not alter the agreement of VT between VRI and EIT. Measurements of regional ventilation distribution by VRI are comparable to those obtained by EIT.

  10. Noninvasive measurement of mean alveolar carbon dioxide tension and Bohr's dead space during tidal breathing.

    PubMed

    Koulouris, N G; Latsi, P; Dimitroulis, J; Jordanoglou, B; Gaga, M; Jordanoglou, J

    2001-06-01

    The lack of methodology for measuring the alveolar carbon dioxide tension (PA,CO2) has forced investigators to make several assumptions, such as that PA,CO2 is equal to end-tidal (PET,CO2) and arterial CO2 tension (Pa,CO2). The present study measured the mean PA,CO2 and Bohr's dead space ratio (Bohr's dead space/tidal volume (VD,Bohr/VT)) during tidal breathing. The method used is a new, simple and noninvasive technique, based on the analysis of the expired CO2 volume per breath (VCO2) versus the exhaled VT. This curve was analysed in 21 normal, healthy subjects and 35 chronic obstructive pulmonary disease (COPD) patients breathing tidally through a mouthpiece apparatus in the sitting position. It is shown that: 1) PA,CO2 is similar to Pa,CO2 in normal subjects, whilst it is significantly lower than Pa,CO2 in COPD patients; 2) PA,CO2 is significantly higher than PET,CO2 in all subjects, especially in COPD patients; 3) VD,Bohr/VT is increased in COPD patients as compared to normal subjects; and 4) VD,Bohr/VT is lower than the "physiological" dead space ratio (VD,phys/VT) in COPD patients. It is concluded that the expired carbon dioxide versus tidal volume curve is a useful tool for research and clinical work, because it permits the noninvasive and accurate measurement of Bohr's dead space and mean alveolar carbon dioxide tension accurately during spontaneous breathing.

  11. Physiological intensity profile, exercise load and performance predictors of a 65-km mountain ultra-marathon.

    PubMed

    Fornasiero, Alessandro; Savoldelli, Aldo; Fruet, Damiano; Boccia, Gennaro; Pellegrini, Barbara; Schena, Federico

    2018-06-01

    The aims of the study were to describe the physiological profile of a 65-km (4000-m cumulative elevation gain) running mountain ultra-marathon (MUM) and to identify predictors of MUM performance. Twenty-three amateur trail-runners performed anthropometric evaluations and an uphill graded exercise test (GXT) for VO 2max, ventilatory thresholds (VTs), power outputs (PMax, PVTs) and heart rate response (HRmax, HR@VTs). Heart rate (HR) was monitored during the race and intensity was expressed as: Zone I (VT2) for exercise load calculation (training impulse, TRIMP). Mean race intensity was 77.1%±4.4% of HRmax distributed as: 85.7%±19.4% Zone I, 13.9%±18.6% Zone II, 0.4%±0.9% Zone III. Exercise load was 766±110 TRIMP units. Race time (11.8±1.6h) was negatively correlated with VO 2max (r = -0.66, P <0.001) and PMax (r = -0.73, P <0.001), resulting these variables determinant in predicting MUM performance, whereas exercise thresholds did not improve performance prediction. Laboratory variables explained only 59% of race time variance, underlining the multi-factorial character of MUM performance. Our results support the idea that VT1 represents a boundary of tolerable intensity in this kind of events, where exercise load is extremely high. This information can be helpful in identifying optimal pacing strategies to complete such extremely demanding MUMs.

  12. Longitudinal dispersion in model of central airways during high-frequency ventilation.

    PubMed

    van der Kooij, A M; Luijendijk, S C

    1991-04-01

    We have measured the longitudinal dispersion of boluses of helium, acetylene and sulphur hexafluoride in a plastic model of the human airways--generations zero through six--during high frequency ventilation (HFV). HFV was maintained by a piston pump. Frequency f and tidal volume VT ranged from 2.5 to 25 Hz and from 5 to 20 ml, respectively. Boluses were injected near the entrance of the zeroth generation (trachea), and the dispersion curves were measured by mass spectrometry at the end of the sixth airway generation. The shapes of the bolus dispersion curves could be well described with Gaussian distribution functions. With the exception of the HFV-conditions with VT = 5 ml, the effective dispersion coefficient DDISP appeared to be independent of the molecular diffusion coefficient. This independency was also found by other investigators in studies with dogs and human subjects. The measured results for DDISP for different f and VT could be satisfactorily described with the empirical equation DDISP = 0.0617 f0.8VT1.38 [cm2S-1]. Application of this equation to f and VT values normally applied in man resulted in DDISP values which should be considered to be too small for maintaining eucapnic ventilation in vivo. On the basis of this result we believe that during HFV in intubated subjects gas transport by longitudinal dispersion will be limited to the instrumental dead space--the endotracheal tube inclusive--and a few generations of large bronchi.

  13. Direct comparison of administration routes for AAV8-mediated ocular gene therapy.

    PubMed

    Igarashi, Tsutomu; Miyake, Koichi; Asakawa, Nagisa; Miyake, Noriko; Shimada, Takashi; Takahashi, Hiroshi

    2013-05-01

    We recently demonstrated that direct subretinal (SR) injection of adeno-associated virus (AAV) type 8 (AAV8) into photoreceptor cells and retinal pigment epithelium (RPE) is a highly efficient model of gene delivery. The current study compared transduction efficiency and expression patterns associated with various routes of vector administration. The efficacy of intravitreal (VT), SR and subconjunctival (SC) injections for delivery of AAV8-derived vectors, i.e. those expressing luciferase (Luc) and enhanced green fluorescent protein (GFP) - AAV8/Luc and AAV8/GFP, respectively - were compared in an animal (mouse) model (n = 8 mice/group). Transduction efficiency and expression patterns were examined at post-injection weeks 1 and 2, and months 1, 3, 6 and 12 via in vivo imaging. One year after AAV injection, AAV8/Luc-treated mice exhibited stable and sustained high expression of vector in the VT and SR groups, but not in the SC group (VT:SR:SC = 3,218:2,923:115; 1 × 10(5 )photons/s). Histological analysis showed that GFP expression was observed in the inner retina of VT group mice, and in photoreceptor cells and RPE of SR group mice, whereas no GFP expression was noted in the SC group. Electroretinography (ERG) revealed adverse effects following SR delivery. Results suggest that both SR and VT injections of AAV8 vectors are useful routes for administering ocular gene therapy, and stress the importance of selecting an appropriate administration route, i.e. one that targets specific cells, for treating ocular disorders.

  14. Successful Multiresistant Community-Associated Methicillin-Resistant Staphylococcus aureus Lineage from Taipei, Taiwan, That Carries Either the Novel Staphylococcal Chromosome Cassette mec (SCCmec) Type VT or SCCmec Type IV

    PubMed Central

    Boyle-Vavra, Susan; Ereshefsky, Ben; Wang, Chih-Chien; Daum, Robert S.

    2005-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) isolates carry the methicillin resistance gene (mecA) on a horizontally transferred genetic element called the staphylococcal chromosome cassette mec (SCCmec). Community-acquired MRSA (CAMRSA) isolates usually carry SCCmec type IV. We previously reported that 76% of 17 CAMRSA isolates (multilocus sequence type 59) obtained from pediatric patients with skin and soft tissue infections (SSTI) from Taipei did not carry SCCmec types I to IV. We used DNA sequence analysis to determine that the element harbored by these nontypeable isolates is a novel subtype of SCCmec V called SCCmec VT. It contains a ccrC recombinase gene variant (ccrC2) and mec complex C2. One SSTI isolate contained molecular features of SCCmec IV but also contained ccrC2 (a feature of SCCmec VT), suggesting that it may harbor a composite SCCmec element. The genes lukS-PV and lukF-PV encoding the Panton-Valentine leukocidin (PVL) were present in all CAMRSA SSTI isolates whether they contained SCCmec type IV or VT. SCCmec VT was also present in 5 of 34 (14.7%) CAMRSA colonization isolates collected from healthy children from Taipei who lacked MRSA risk factors. Four (80%) of the these isolates contained lukS-PV and lukF-PV, as did 1 of 27 (3.7%) SCCmec IV-containing colonization isolates. A total of 63% (10 of 16) of the SSTI isolates and 61.7% (21 of 34) of the colonization isolates tested were resistant to at least four classes of non-β-lactam antimicrobials. SCCmec VT is a novel SCCmec variant that is found in multiply resistant CAMRSA strains with sequence type 59 in Taipei in association with the PVL leukotoxin genes. PMID:16145133

  15. Long-term efficacy of single procedure remote magnetic catheter navigation for ablation of ischemic ventricular tachycardia: a retrospective study.

    PubMed

    Dinov, Borislav; Schönbauer, Robert; Wojdyla-Hordynska, Agnieska; Braunschweig, Frieder; Richter, Sergio; Altmann, David; Sommer, Philipp; Gaspar, Thomas; Bollmann, Andreas; Wetzel, Ulrike; Rolf, Sascha; Piorkowski, Christopher; Hindricks, Gerhard; Arya, Arash

    2012-05-01

    Remote magnetic navigation (RMN) aims to reduce some inherent limitations of manual radiofrequency (RF) ablation. However, data comparing the effectiveness of both methods are scarce. This study evaluated the acute and long-term success of RMN guided versus manual RF ablation in patients with ischemic sustained ventricular tachycardia (sVT). One hundred two consecutive patients (age 68 ± 10 years, LVEF 32 ± 12%, 88 men) with ischemic sVT were ablated with RMN (Stereotaxis; 49%) or manually (51%) using substrate and/or activation mapping (Carto) and open-irrigated-tip catheters. All received implantable defibrillators or loop recorders. Acute success was defined as noninducibility of any sVT at the end of the ablation procedure and long-term success as freedom from VT upon follow-up. There was no difference in the baseline characteristics between the groups. Three patients died in hospital. Acute success rate was similar for RMN and manual ablation (82% vs 71%, P = 0.246). RMN was associated with significantly shorter fluoroscopy time (13 ± 12 minutes vs 32 ± 17 minutes, P = 0.0001) and RF time (2337.59 ± 1248.22 seconds vs 1589.95 ± 1047.42 seconds, P = 0.049), although total procedure time was similar (157 ± 40 minutes vs 148 ± 50 minutes, P = 0.42). There was a nonsignificant trend toward better long-term success in RMN group: after a median of 13 (range 1-34) months, 63% in the RMN and 53% in the manual ablation group were free from VT recurrence (P = 0.206). RMN guided RF ablation of ischemic sustained VT is equally efficient compared with manual ablation in terms of acute and long-term success rate. These results are achieved with a significantly reduced fluoroscopy time and shorter RF time. © 2012 Wiley Periodicals, Inc.

  16. Tennis Play Intensity Distribution and Relation with Aerobic Fitness in Competitive Players

    PubMed Central

    Baiget, Ernest; Fernández-Fernández, Jaime; Iglesias, Xavier; Rodríguez, Ferran A.

    2015-01-01

    The aims of this study were (i) to describe the relative intensity of simulated tennis play based on the cumulative time spent in three metabolic intensity zones, and (ii) to determine the relationships between this play intensity distribution and the aerobic fitness of a group of competitive players. 20 male players of advanced to elite level (ITN) performed an incremental on-court specific endurance tennis test to exhaustion to determine maximal oxygen uptake (VO2max) and the first and second ventilatory thresholds (VT1, VT2). Ventilatory and gas exchange parameters were monitored using a telemetric portable gas analyser (K4 b2, Cosmed, Rome, Italy). Two weeks later the participants played a simulated tennis set against an opponent of similar level. Intensity zones (1: low, 2: moderate, and 3: high) were delimited by the individual VO2 values corresponding to VT1 and VT2, and expressed as percentage of maximum VO2 and heart rate. When expressed relative to VO2max, percentage of playing time in zone 1 (77 ± 25%) was significantly higher (p < 0.001) than in zone 2 (20 ± 21%) and zone 3 (3 ± 5%). Moderate to high positive correlations were found between VT1, VT2 and VO2max, and the percentage of playing time spent in zone 1 (r = 0.68–0.75), as well as low to high inverse correlations between the metabolic variables and the percentage of time spent in zone 2 and 3 (r = -0.49–0.75). Players with better aerobic fitness play at relatively lower intensities. We conclude that players spent more than 75% of the time in their low-intensity zone, with less than 25% of the time spent at moderate to high intensities. Aerobic fitness appears to determine the metabolic intensity that players can sustain throughout the game. PMID:26098638

  17. Using Kalman Filter Chemical Data Assimilation to Study Ozone Catalytic Loss Cycles in January 1992

    NASA Technical Reports Server (NTRS)

    Lary, David J.

    2002-01-01

    This paper presents for the first time a global study of the ozone catalytic destruction cycles operating in the stratosphere using a stratospheric analyses for January 1992. The chemical analyses were produced using a Kalman filter data assimilation system. Because a major component of the variability of trace gases is due to the atmospheric motions the analyses have been cast in a flow-tracking coordinate system that moves with the large scale flow pattern. Particular attention is paid to the kinetic aspects of these cycles such as the rate limiting step and chain length. Although it is an important kinetic parameter, the chain length of the various cycles is seldom considered when the various catalytic cycles are discussed. This survey highlights that in the low stratosphere the cycles involving HO2 and halogens (notably bromine) are particularly important. In approximate order of effectiveness the most important ozone loss cycles in the polar lower stratosphere are the BrO/ClO, HO2/BrO, and OH/HO2 cycles. The ClO/ClO cycle clearly delineates the regions of chlorine activation. The chain length of the HO2/ClO, OH/HO2, Br/BrO, and ClO/NO2, clearly delineate the vortex edge region. The chain length of the BrO/NO2 and Cl/NO2 cycles highlight the regions of chemical processing outside the vortex where streamers of chemically processed air are stripped-off and transported away from the vortex. This is also true in the very low stratosphere for the Cl/ClO and BrO/ClO cycles.

  18. DNA forms of the geminivirus African cassava mosaic virus consistent with a rolling circle mechanism of replication.

    PubMed Central

    Saunders, K; Lucy, A; Stanley, J

    1991-01-01

    We have analysed DNA from African cassava mosaic virus (ACMV)-infected Nicotiana benthamiana by two-dimensional agarose gel electrophoresis and detected ACMV-specific DNAs by blot-hybridisation. ACMV DNA forms including the previously characterised single-stranded, open-circular, linear and supercoiled DNAs along with five previously uncharacterised heterogeneous DNAs (H1-H5) were resolved. The heterogeneous DNAs were characterised by their chromatographic properties on BND-cellulose and their ability to hybridise to strand-specific and double-stranded probes. The data suggest a rolling circle mechanism of DNA replication, based on the sizes and strand specificity of the heterogeneous single-stranded DNA forms and their electrophoretic properties in relation to genome length single-stranded DNAs. Second-strand synthesis on a single-stranded virus-sense template is evident from the position of heterogeneous subgenomic complementary-sense DNA (H3) associated with genome-length virus-sense template (VT) DNA. The position of heterogeneous virus-sense DNA (H5), ranging in size from one to two genome lengths, is consistent with its association with genome-length complementary-sense template (CT) DNA, reflecting virus-sense strand displacement during replication from a double-stranded intermediate. The absence of subgenomic complementary-sense DNA associated with the displaced virus-sense strand suggests that replication proceeds via an obligate single-stranded intermediate. The other species of heterogeneous DNAs comprised concatemeric single-stranded virus-sense DNA (H4), and double-stranded or partially single-stranded DNA (H1 and H2). Images PMID:2041773

  19. Origins location of the outflow tract ventricular arrhythmias exhibiting qrS pattern or QS pattern with a notch on the descending limb in lead V1.

    PubMed

    Lin, Cong; Zheng, Cheng; Zhou, De-Pu; Li, Xiao-Wei; Wu, Shu-Jie; Lin, Jia-Feng

    2017-05-15

    Ventricular outflow tract(VOT) ventricular arrhythmias(VAs) presenting qrS pattern or QS pattern with a notch on the descending limb in lead V1 were consistently thought of arising from the commissure between left and right coronary cusp (L-RCC) by previous studies. However, we found they could originate from other anatomic structures in VOT. This study aimed to investigate the exact origin of this kind VAs. Forty-nine patients of VOT premature ventricular contrations/ventricular tachycardia(PVCs/VT) with lead V1 presenting qrS pattern or QS pattern with a notch on the descending limb undergoing successful radiofrequency catheter ablation(RFCA) in our center were analyzed. 12-lead electrocardiogram(ECG) of these PVCs/VT were summarized. Among these PVCs/VT, 37 cases exhibited qrS morphology in lead V1, 12 cases presented QS pattern with a notch on the descending limb in the same lead. Based on the successful ablation sites, these PVCs/VT were divided into 2 groups: (1)Right ventricular outflow tract(RVOT) group (26 cases), and (2) Left ventricular outflow tract (LVOT) group(23 cases, 4 cases originating from the left coronary cusp(LCC), 2 from the right coronary cusp(RCC), 16 from the L-RCC, 1 from the area inferior to LCC(ILCC)). The ECG characteristics of each PVCs/VT were analyzed. Among these PVCs/VT, applying the precordial transitional zone index(TZ index) < 0 to predict LVOT origin was demonstrated with sensitivity of 95.65%, specificity of 96.15%, positive predicting value(PPV) of 95.65% and negative predicting value(NPV) of 96.15%. In LVOT group, further applying the r, R, m,or Rs morphology in lead I to predict L-RCC and RCC origin was demonstrated with sensitivity of 94.44%, specificity of 60.00%, PPV of 89.47% and NPV of 75.00%. Ventricular outflow tract PVCs/VT with lead V1 presenting qrS pattern or QS pattern with a notch on descending limb not only arising from L-RCC, but also RVOT, LCC, RCC and ILCC. Combining TZ index and QRS morphology in lead I to predict origin site of these kind VAs is a convenient, simple and reliable method and facilitates the RFCA procedure.

  20. Aerobic Physical Exercise Improved the Cognitive Function of Elderly Males but Did Not Modify Their Blood Homocysteine Levels

    PubMed Central

    Antunes, Hanna Karen M.; De Mello, Marco Túlio; de Aquino Lemos, Valdir; Santos-Galduróz, Ruth Ferreira; Camargo Galdieri, Luciano; Amodeo Bueno, Orlando Francisco; Tufik, Sergio; D'Almeida, Vânia

    2015-01-01

    Background Physical exercise influences homocysteine (Hcy) concentrations, cognitive function and the metabolic profile. The purpose of this study was to investigate the influence of regular physical exercise on Hcy levels, the metabolic profile and cognitive function in healthy elderly males before and after an endurance exercise program. Methods Forty-five healthy and sedentary volunteers were randomized into 2 groups: (1) a control group asked not to change their normal everyday activities and not to start any regular physical exercise program and (2) an experimental group trained at a heart rate intensity corresponding to ventilatory threshold 1 (VT-1) for 60 min/day 3 times weekly on alternate days for 6 months using a cycle ergometer. All volunteers underwent cognitive evaluations, blood sample analyses and ergospirometric assessments. Results A significant improvement in cognitive function was observed in the experimental group compared with the control group (p < 0.05). No significant changes in Hcy levels were observed in the experimental group (p > 0.05), but there was a significant increase in peak oxygen consumption and workload at VT-1 as well as a significant improvement in cholesterol, triglycerides, HDL, glucose, alkaline phosphatase, urea, T3, T4 and prostate-specific antigen compared with the control group (p < 0.05). Conclusion The data suggest that a physical exercise program does not reduce Hcy levels in healthy elderly males, although it improves the cardiovascular and metabolic profile as well as cognitive function. PMID:25759715

  1. The Consumer and His Dollars: A Workbook and Study Guide.

    ERIC Educational Resources Information Center

    Finegan, Marcella E.

    This workbook and study guide for a money management curriculum in consumer education was written to accompany the textbook "The Consumer and His Dollars" and a teacher's guide, both announced in this issue as VT 017 179 and VT 017 177. Included are 16 chapters, each containing worksheets perforated for easy removal. Chapter highlights,…

  2. Educational Applications of Vision Therapy: A Pilot Study on Children with Autism.

    ERIC Educational Resources Information Center

    Lovelace, Kelly; Rhodes, Heidi; Chambliss, Catherine

    This report discusses the outcomes of a study that explored the feasibility of using vision therapy (VT) as part of an interdisciplinary approach to the education of children with autism. Traditional research on VT has explored its usefulness in helping patients to use both eyes together, improve depth perception, and enhance visual acuity.…

  3. MECHANICAL TECHNOLOGY, DESIGN AND PRODUCTION, SUGGESTED TECHNIQUES FOR DETERMINING COURSES OF STUDY IN VOCATIONAL EDUCATION PROGRAMS.

    ERIC Educational Resources Information Center

    PETERSON, CLARENCE E.

    THIS PUBLICATION IS THE THIRD IN A SERIES DESIGNED TO PROVIDE INFORMATION TO HELP STATES ORGANIZE AND OPERATE PROGRAMS UNDER TITLE VIII OF THE NATIONAL DEFENSE EDUCATION ACT OF 1958. THE OTHER PUBLICATIONS ARE "MECHANICAL DRAFTING AND DESIGN TECHNOLOGY" (VT 001 823) AND "ELECTRICAL AND ELECTRONIC TECHNOLOGY" (VT 002 421). EACH…

  4. Vocational Education and Training in the Federal Republic of Germany. Report for the FORCE Programme. First Edition.

    ERIC Educational Resources Information Center

    Munch, Joachim

    This monograph examines vocational training (VT) in the Federal Republic of Germany. Section 1 presents background information/framework data on the following: Germany's political and administrative structures, population and demographic trends, economy and employment, and education system. In section 2, the historical development of VT in Germany…

  5. 25-Hydroxyvitamin D and Long Menstrual Cycles in a Prospective Cohort Study.

    PubMed

    Jukic, Anne Marie Z; Wilcox, Allen J; McConnaughey, D Robert; Weinberg, Clarice R; Steiner, Anne Z

    2018-05-01

    Vitamin D insufficiency is associated with subfertility and prolonged estrus cycles in animals, but humans have not been well studied. A prospective time-to-pregnancy study, Time to Conceive (2010-2015), collected up to 4 months of daily diary data. Participants were healthy, late reproductive-aged women in North Carolina who were attempting pregnancy. We examined menstrual cycle length as a continuous variable and in categories: long (35+ days) and short (≤25 days). Follicular phase length and luteal phase length were categorized as long (18+ days) or short (≤10 days). We estimated associations between those lengths and serum 25-hydroxyvitamin D (25[OH]D) using linear mixed models and marginal models. There were 1,278 menstrual cycles from 446 women of whom 5% were vitamin D deficient (25[OH]D, <20 ng/ml), 69% were between 20 and 39 ng/ml, and 26% were 40 ng/ml or higher. There was a dose-response association between vitamin D levels and cycle length. Compared with the highest 25(OH)D level (≥40 ng/ml), 25(OH)D deficiency was associated with almost three times the odds of long cycles (adjusted odds ratio [aOR] = 2.8 [95% confidence interval (CI) = 1.0, 7.5]). The aOR was 1.9 (1.1, 3.5) for 20 to <30 ng/ml. The probability of a long follicular phase and the probability of a short luteal phase both increased with decreasing 25(OH)D. Lower levels of 25(OH)D are associated with longer follicular phase and an overall longer menstrual cycle. Our results are consistent with other evidence supporting vitamin D's role in the reproductive axis, which may have broader implications for reproductive success.

  6. Perfluoroalkyl Chemicals, Menstrual Cycle Length, and Fecundity: Findings from a Prospective Pregnancy Study

    PubMed Central

    Lum, Kirsten J.; Sundaram, Rajeshwari; Barr, Dana Boyd; Louis, Thomas A.; Louis, Germaine M. Buck

    2016-01-01

    Background Perfluoroalkyl substances have been associated with changes in menstrual cycle characteristics and fecundity, when modeled separately. However, these outcomes are biologically related, and we evaluate their joint association with exposure to perfluoroalkyl substances. Methods We recruited 501 couples from Michigan and Texas in 2005-2009 upon their discontinuing contraception and followed them until pregnancy or 12 months of trying. Female partners provided a serum sample upon enrollment and completed daily journals on menstruation, intercourse, and pregnancy test results. We measured seven perfluoroalkyl substances in serum using liquid-chromatography-tandem mass spectrometry. We assessed the association between perfluoroalkyl substances and menstrual cycle length using accelerated failure time models and between perfluoroalkyl substances and fecundity using a Bayesian joint modeling approach to incorporate cycle length. Results Menstrual cycles were 3% longer comparing women in the second versus first tertile of perfluorodecanoate (PFDeA; acceleration factor [AF]=1.03, 95% credible interval [CrI]=[1.00, 1.05]), but 2% shorter for women in the highest versus lowest tertile of perfluorooctanoic acid (PFOA) (AF=0.98, 95% CrI=[0.96, 1.00]). When accounting for cycle length, relevant covariates and remaining perfluoroalkyl substances, the probability of pregnancy was lower for women in second versus first tertile of PFNA (odds ratio [OR]=0.6, 95% CrI=[0.4, 1.0]) though not when comparing the highest versus lowest (OR=0.7, 95% CrI=[0.3, 1.1]) tertile. Conclusions In this prospective cohort study, we observed associations between two perfluoroalkyl substances and menstrual cycle length changes, and between select perfluoroalkyl substances and diminished fecundity at some (but not all) concentrations. PMID:27541842

  7. Effective dominance of resistance of Spodoptera frugiperda to Bt maize and cotton varieties: implications for resistance management

    PubMed Central

    Horikoshi, Renato J.; Bernardi, Daniel; Bernardi, Oderlei; Malaquias, José B.; Okuma, Daniela M.; Miraldo, Leonardo L.; Amaral, Fernando S. de A. e; Omoto, Celso

    2016-01-01

    The resistance of fall armyworm (FAW), Spodoptera frugiperda, has been characterized to some Cry and Vip3A proteins of Bacillus thuringiensis (Bt) expressed in transgenic maize in Brazil. Here we evaluated the effective dominance of resistance based on the survival of neonates from selected Bt-resistant, heterozygous, and susceptible (Sus) strains of FAW on different Bt maize and cotton varieties. High survival of strains resistant to the Cry1F (HX-R), Cry1A.105/Cry2Ab (VT-R) and Cry1A.105/Cry2Ab/Cry1F (PW-R) proteins was detected on Herculex, YieldGard VT PRO and PowerCore maize. Our Vip3A-resistant strain (Vip-R) exhibited high survival on Herculex, Agrisure Viptera and Agrisure Viptera 3 maize. However, the heterozygous from HX-R × Sus, VT-R × Sus, PW-R × Sus and Vip-R × Sus had complete mortality on YieldGard VT PRO, PowerCore, Agrisure Viptera, and Agrisure Viptera 3, whereas the HX-R × Sus and Vip-R × Sus strains survived on Herculex maize. On Bt cotton, the HX-R, VT-R and PW-R strains exhibited high survival on Bollgard II. All resistant strains survived on WideStrike, but only PW-R and Vip-R × Sus survived on TwinLink. Our study provides useful data to aid in the understanding of the effectiveness of the refuge strategy for Insect Resistance Management of Bt plants. PMID:27721425

  8. A ``NEW'' Solid-Core Reactor Fuel Form that Maximizes the Performance of Nuclear Thermal and Electric Rockets

    NASA Astrophysics Data System (ADS)

    Rom, Frank E.; Finnegan, Patrick M.

    1994-07-01

    The ``NEW'' solid-core fuel form is the old Vapor Transport (VT) fuel pin investigated at NASA about 30 years ago. It is simply a tube sealed at both ends partially filled with UO2. During operation the UO2 forms an annular layer on the inside of the tube by vaporization and condensation. This form is an ideal structure for overall strength and retention of fission products. All of the structural material lies between the fuel (including fission products) and the reactor coolant. The isothermal inside fuel surface temperature that results from the vaporization and condensation of fuel during operation eliminates hotspots, significantly increasing the design fuel pin surface temperature. For NTP, W-UO2 fuel pins yield higher operating temperatures than for other fuel forms, because W has about a ten-fold lower vaporization rate compared to any other known material. The use of perigee propulsion using W-UO2 fuel pins can result in a more than ten-fold reduction in reactor power. Lower reactor power, together with zero fission product release potential, and the simplicity of fabrication of VT fuel pins should greatly simplify and reduce the cost of development of NTP. For NEP, VT fuel pins can increase fast neutron spectrum reactor life with no fission product release. Thermal spectrum NEP reactors using W184 or Mo VT fuel pins, with only small amounts of high neutron absorbing additives, offer benefits because of much lower fissionable fuel requirements. The VT fuel pin has application to commercial power reactors with similar benefits.

  9. Volume-controlled Ventilation Does Not Prevent Injurious Inflation during Spontaneous Effort.

    PubMed

    Yoshida, Takeshi; Nakahashi, Susumu; Nakamura, Maria Aparecida Miyuki; Koyama, Yukiko; Roldan, Rollin; Torsani, Vinicius; De Santis, Roberta R; Gomes, Susimeire; Uchiyama, Akinori; Amato, Marcelo B P; Kavanagh, Brian P; Fujino, Yuji

    2017-09-01

    Spontaneous breathing during mechanical ventilation increases transpulmonary pressure and Vt, and worsens lung injury. Intuitively, controlling Vt and transpulmonary pressure might limit injury caused by added spontaneous effort. To test the hypothesis that, during spontaneous effort in injured lungs, limitation of Vt and transpulmonary pressure by volume-controlled ventilation results in less injurious patterns of inflation. Dynamic computed tomography was used to determine patterns of regional inflation in rabbits with injured lungs during volume-controlled or pressure-controlled ventilation. Transpulmonary pressure was estimated by using esophageal balloon manometry [Pl(es)] with and without spontaneous effort. Local dependent lung stress was estimated as the swing (inspiratory change) in transpulmonary pressure measured by intrapleural manometry in dependent lung and was compared with the swing in Pl(es). Electrical impedance tomography was performed to evaluate the inflation pattern in a larger animal (pig) and in a patient with acute respiratory distress syndrome. Spontaneous breathing in injured lungs increased Pl(es) during pressure-controlled (but not volume-controlled) ventilation, but the pattern of dependent lung inflation was the same in both modes. In volume-controlled ventilation, spontaneous effort caused greater inflation and tidal recruitment of dorsal regions (greater than twofold) compared with during muscle paralysis, despite the same Vt and Pl(es). This was caused by higher local dependent lung stress (measured by intrapleural manometry). In injured lungs, esophageal manometry underestimated local dependent pleural pressure changes during spontaneous effort. Limitation of Vt and Pl(es) by volume-controlled ventilation could not eliminate harm caused by spontaneous breathing unless the level of spontaneous effort was lowered and local dependent lung stress was reduced.

  10. Use of Virtual Technology as an Intervention for Wheelchair Skills Training: A Systematic Review.

    PubMed

    Lam, Jean-François; Gosselin, Laurent; Rushton, Paula W

    2018-03-10

    To provide a comprehensive description of the current state of knowledge regarding the use of virtual technology (VT) for wheelchair skills training. The Cochrane Library, MEDLINE, CINAHL, Embase, ACM, IEEE Xplore, Inspec, and Web of Science databases were searched for relevant articles from 1990 to February 2016. We included peer-reviewed studies or long conference proceedings that examined the use of VT as a medium to provide a wheelchair skills training intervention for any population with any diagnosis using any research design. One investigator screened the titles and abstracts, then 2 investigators independently reviewed the full-text articles. Disagreements regarding inclusion were resolved by consensus or a third reviewer. Ten studies were included out of 4994 initially identified. Two investigators extracted data to systematically assess the studies' findings into 5 tables (study design and participant characteristics, equipment and technology used, intervention characteristics, outcome measures, and outcomes). Most studies demonstrated that VT wheelchair skills training showed improved outcomes (eg, simulation score, completion time, number of collisions) in the virtual environment and/or in the real world. However, subject characteristics, equipment, virtual environment, intervention tasks, and outcome measures varied across the studies. There are a variety of studies using VT as an intervention for wheelchair skills training. Given the positive outcomes for most of the studies, it appears as though VT may indeed be a solution that can help to alleviate barriers to wheelchair skills training and subsequently improve wheelchair user skill. Copyright © 2018 American Congress of Rehabilitation Medicine. All rights reserved.

  11. Multiplexed targeted proteomic assay to assess coagulation factor concentrations and thrombosis-associated cancer

    PubMed Central

    van Vlijmen, Bart J.; Yang, Juncong; Percy, Andrew J.

    2017-01-01

    The plasma levels of pro- and anticoagulant proteins are important markers for venous thrombosis (VT) risk and can be affected by both genetic and acquired factors, including cancer. Generally, these markers are measured using activity- or antibody-based assays. Targeted proteomics with stable-isotope–labeled internal standards has proven adept at the rapid, multiplex, and precise quantification of proteins in complex biological samples such as plasma. We used liquid chromatography coupled to multiple reaction monitoring (MRM) mass spectrometry to evaluate the concentrations of 31 coagulation- and fibrinolysis-related proteins in plasma from 25 healthy controls, 25 patients with VT, and 25 patients with VT who were also diagnosed with cancer. The concentration level of 1 to 3 proteotypic peptides per protein was determined, and all samples were previously characterized using traditional antibody- or activity-based methods. When comparing the conventional and the MRM strategies, the mean Pearson correlation for the 13 proteins (covered by 36 target peptides) shared between the 2 approaches was 0.77, indicating a good correlation. Additionally, MRM offers higher sensitivity (mean regression slope, 0.81), higher multiplicity in a single run, and good ability to leverage all measurements to discriminate groups using unsupervised clustering, which identified vitamin K antagonist users as well as patients with VT and cancer. The data collected using MRM show that the combination of coagulation factor levels yields signature information on VT and cancer, which was not obvious from a single measurement. These results encourage the further validation and investigation of MRM in profiling protein signature of disease. PMID:29296750

  12. No change in the regional distribution of tidal volume during lateral posture in mechanically ventilated patients assessed by electrical impedance tomography.

    PubMed

    Bein, Thomas; Ploner, Franz; Ritzka, Markus; Pfeifer, Michael; Schlitt, Hans J; Graf, Bernhard M

    2010-07-01

    We assessed the distribution of regional lung ventilation during moderate and steep lateral posture using electrical impedance tomography (EIT) in mechanically ventilated patients. Seven patients were placed on a kinetic treatment table. An elastic belt containing 16 electrodes was placed around the chest and was connected to the EIT device. Patients were moved to left and right lateral positions in a stepwise (10 degrees ) mode up to 60 degrees. EIT images [arbitrary units (AU)] were generated and scanned for assessment of relative ventilation distribution changes [tidal volume (V(T))]. A calibration procedure of arbitrary units (AUs) versus ventilator-derived V(T) performed in all patients during three predefined positions (supine, 60 degrees-left dependent and 60 degrees-right-dependent) showed a significant correlation between V(T) in supine, left and right lateral positions with the corresponding AUs (r(2) = 0.356, P<0.05). Changes in V(T) were calculated and compared to supine position, and specific regions of interest (ROIs) were analysed. In our study, in contrast to recent findings, a change in lateral positions did not induce a significant change in regional tidal volume distribution. In right lateral positions, a broader variation of V(T) with a trend towards an increase in the dependently positioned lung was observed in comparison with supine. Lateral positioning promotes the redistribution of ventilation to the ventral regions of the lung. The use of EIT technology might become a helpful tool for understanding and guiding posture therapy in mechanically ventilated patients.

  13. Evaluation of manual resuscitators used in ICUs in Brazil*

    PubMed Central

    Ortiz, Tatiana de Arruda; Forti, Germano; Volpe, Márcia Souza; Beraldo, Marcelo do Amaral; Amato, Marcelo Britto Passos; Carvalho, Carlos Roberto Ribeiro; Tucci, Mauro Roberto

    2013-01-01

    OBJECTIVE: To evaluate the performance of manual resuscitators (MRs) used in Brazil in accordance with international standards. METHODS: Using a respiratory system simulator, four volunteer physiotherapists employed eight MRs (five produced in Brazil and three produced abroad), which were tested for inspiratory and expiratory resistance of the patient valve; functioning of the pressure-limiting valve; and tidal volume (VT) generated when the one-handed and two-handed techniques were used. The tests were performed and analyzed in accordance with the American Society for Testing and Materials (ASTM) F920-93 criteria. RESULTS: Expiratory resistance was greater than 6 cmH2O . L−1 . s−1 in only one MR. The pressure-limiting valve, a feature of five of the MRs, opened at low pressures (< 17 cmH2O), and the maximal pressure was 32.0-55.9 cmH2O. Mean VT varied greatly among the MRs tested. The mean VT values generated with the one-handed technique were lower than the 600 mL recommended by the ASTM. In the situations studied, mean VT was generally lower from the Brazilian-made MRs that had a pressure-limiting valve. CONCLUSIONS: The resistances imposed by the patient valve met the ASTM criteria in all but one of the MRs tested. The pressure-limiting valves of the Brazilian-made MRs usually opened at low pressures, providing lower VT values in the situations studied, especially when the one-handed technique was used, suggesting that both hands should be used and that the pressure-limiting valve should be closed whenever possible. PMID:24310633

  14. No change in the regional distribution of tidal volume during lateral posture in mechanically ventilated patients assessed by electrical impedance tomography

    PubMed Central

    Bein, Thomas; Ploner, Franz; Ritzka, Markus; Pfeifer, Michael; Schlitt, Hans J; Graf, Bernhard M

    2010-01-01

    We assessed the distribution of regional lung ventilation during moderate and steep lateral posture using electrical impedance tomography (EIT) in mechanically ventilated patients. Seven patients were placed on a kinetic treatment table. An elastic belt containing 16 electrodes was placed around the chest and was connected to the EIT device. Patients were moved to left and right lateral positions in a stepwise (10°) mode up to 60°. EIT images [arbitrary units (AU)] were generated and scanned for assessment of relative ventilation distribution changes [tidal volume (VT)]. A calibration procedure of arbitrary units (AUs) versus ventilator-derived VT performed in all patients during three predefined positions (supine, 60°-left dependent and 60°-right-dependent) showed a significant correlation between VT in supine, left and right lateral positions with the corresponding AUs (r2 = 0·356, P<0·05). Changes in VT were calculated and compared to supine position, and specific regions of interest (ROIs) were analysed. In our study, in contrast to recent findings, a change in lateral positions did not induce a significant change in regional tidal volume distribution. In right lateral positions, a broader variation of VT with a trend towards an increase in the dependently positioned lung was observed in comparison with supine. Lateral positioning promotes the redistribution of ventilation to the ventral regions of the lung. The use of EIT technology might become a helpful tool for understanding and guiding posture therapy in mechanically ventilated patients. PMID:20491842

  15. Behavioral effects of hindbrain vasotocin in goldfish are seasonally variable but not sexually dimorphic

    PubMed Central

    Walton, James C.; Waxman, Brandon; Hoffbuhr, Kristen; Kennedy, Meaghan; Beth, Ellen; Scangos, Jennifer; Thompson, Richmond R.

    2013-01-01

    We have previously demonstrated that centrally administered vasotocin (VT) inhibits social approach toward same-sex conspecifics in male and female goldfish, and that this behavioral effect is dependent upon VT projections to the hindbrain. We now show that there are no sex differences in sensitivity to the behavioral effects of VT, though differences do exist in responsiveness across seasons in both sexes. A central dose of 1 µg, but not 200 ng, inhibited social approach in goldfish in non-reproductive condition, whereas a dose as low as 40 ng inhibited social approach in fish in full reproductive condition. In males and females in full reproductive condition, social approach behavior was facilitated by central administration of 500 ng of a V1A specific antagonist. In addition, the behavioral effects of exogenously administered central VT were blocked by central administration of 1 µg of a V1A antagonist. These results demonstrate that the propensity to approach a conspecific, a simple behavior underlying many social interactions, is controlled by a V1A-like receptor, and that VT’s behavioral effects depend on reproductive context. Quantitative real-time PCR showed that the seasonal changes in behavioral responsiveness to VT are associated with changes in the expression of a V1A-like receptor in the hindbrain, but not the mid- or forebrain, indicating that the seasonal regulation of social approach behavior likely depends on the local modulation of the expression of this receptor within a primitive peptide circuit in this species. PMID:19616564

  16. A verotoxin 1 B subunit-lambda CRO chimeric protein specifically binds both DNA and globotriaosylceramide (Gb(3)) to effect nuclear targeting of exogenous DNA in Gb(3) positive cells.

    PubMed

    Facchini, L M; Lingwood, C A

    2001-09-10

    Inefficient nuclear incorporation of foreign DNA remains a critical roadblock in the development of effective nonviral gene delivery systems. DNA delivered by traditional protocols remains within endosomal/lysosomal vesicles, or is rapidly degraded in the cytoplasm. Verotoxin I (VT), an AB(5) subunit toxin produced by enterohaemorrhagic Escherichia coli, binds to the cell surface glycolipid, globotriaosylceramide (Gb(3)) and is internalized into preendosomes. VT is then retrograde transported to the Golgi, endoplasmic reticulum (ER), and nucleus of highly VT-sensitive cells. We have utilized this nuclear targeting of VT to design a unique delivery system which transports exogenous DNA via vesicular traffic to the nucleus. The nontoxic VT binding subunit (VTB) was fused to the lambda Cro DNA-binding repressor, generating a 14-kDa VTB-Cro chimera. VTB-Cro binds specifically via the Cro domain to a 25-bp DNA fragment containing the consensus Cro operator. VTB-Cro demonstrates simultaneous specific binding to Gb(3). Treatment of Vero cells with fluorescent-labeled Cro operator DNA in the presence of VTB-Cro, results in DNA internalization to the Golgi, ER, and nucleus, whereas fluorescent DNA alone is incorporated poorly and randomly within the cytoplasm. VTB-Cro mediated nuclear DNA transport is prevented by brefeldin A, consistent with Golgi/ER intracellular routing. Pretreatment with filipin had no effect, indicating that caveoli are not involved. This novel VTB-Cro shuttle protein may find practical applications in the fields of intracellular targeting, gene delivery, and gene therapy. Copyright 2001 Academic Press.

  17. Assessment of Regional Ventilation Distribution: Comparison of Vibration Response Imaging (VRI) with Electrical Impedance Tomography (EIT)

    PubMed Central

    Bentley, Alexander H.; Hartmann, Erik K.; Klein, Klaus U.; Bodenstein, Marc; Baumgardner, James E.; David, Matthias; Ullrich, Roman; Markstaller, Klaus

    2014-01-01

    Background Vibration response imaging (VRI) is a bedside technology to monitor ventilation by detecting lung sound vibrations. It is currently unknown whether VRI is able to accurately monitor the local distribution of ventilation within the lungs. We therefore compared VRI to electrical impedance tomography (EIT), an established technique used for the assessment of regional ventilation. Methodology/Principal Findings Simultaneous EIT and VRI measurements were performed in the healthy and injured lungs (ALI; induced by saline lavage) at different PEEP levels (0, 5, 10, 15 mbar) in nine piglets. Vibration energy amplitude (VEA) by VRI, and amplitudes of relative impedance changes (rel.ΔZ) by EIT, were evaluated in seven regions of interest (ROIs). To assess the distribution of tidal volume (VT) by VRI and EIT, absolute values were normalized to the VT obtained by simultaneous spirometry measurements. Redistribution of ventilation by ALI and PEEP was detected by VRI and EIT. The linear correlation between pooled VT by VEA and rel.ΔZ was R2 = 0.96. Bland-Altman analysis showed a bias of −1.07±24.71 ml and limits of agreement of −49.05 to +47.36 ml. Within the different ROIs, correlations of VT-distribution by EIT and VRI ranged between R2 values of 0.29 and 0.96. ALI and PEEP did not alter the agreement of VT between VRI and EIT. Conclusions/Significance Measurements of regional ventilation distribution by VRI are comparable to those obtained by EIT. PMID:24475160

  18. Predicting the response of the injured lung to the mechanical breath profile

    PubMed Central

    Smith, Bradford J.; Lundblad, Lennart K. A.; Kollisch-Singule, Michaela; Satalin, Joshua; Nieman, Gary; Habashi, Nader

    2015-01-01

    Mechanical ventilation is a crucial component of the supportive care provided to patients with acute respiratory distress syndrome. Current practice stipulates the use of a low tidal volume (Vt) of 6 ml/kg ideal body weight, the presumptive notion being that this limits overdistension of the tissues and thus reduces volutrauma. We have recently found, however, that airway pressure release ventilation (APRV) is efficacious at preventing ventilator-induced lung injury, yet APRV has a very different mechanical breath profile compared with conventional low-Vt ventilation. To gain insight into the relative merits of these two ventilation modes, we measured lung mechanics and derecruitability in rats before and following Tween lavage. We fit to these lung mechanics measurements a computational model of the lung that accounts for both the degree of tissue distension of the open lung and the amount of lung derecruitment that takes place as a function of time. Using this model, we predicted how tissue distension, open lung fraction, and intratidal recruitment vary as a function of ventilator settings both for conventional low-Vt ventilation and for APRV. Our predictions indicate that APRV is more effective at recruiting the lung than low-Vt ventilation, but without causing more overdistension of the tissues. On the other hand, low-Vt ventilation generally produces less intratidal recruitment than APRV. Predictions such as these may be useful for deciding on the relative benefits of different ventilation modes and thus may serve as a means for determining how to ventilate a given lung in the least injurious fashion. PMID:25635004

  19. A Microbiomic Analysis in African Americans with Colonic Lesions Reveals Streptococcus sp.VT162 as a Marker of Neoplastic Transformation

    PubMed Central

    Brim, Hassan; Yooseph, Shibu; Lee, Edward; Sherif, Zaki A.; Abbas, Muneer; Laiyemo, Adeyinka O.; Varma, Sudhir; Torralba, Manolito; Dowd, Scot E.; Nelson, Karen E.; Pathmasiri, Wimal; Sumner, Susan; de Vos, Willem; Liang, Qiaoyi; Yu, Jun; Zoetendal, Erwin; Ashktorab, Hassan

    2017-01-01

    Increasing evidence suggests a role of the gut microbiota in colorectal carcinogenesis (CRC). To detect bacterial markers of colorectal cancer in African Americans a metabolomic analysis was performed on fecal water extracts. DNA from stool samples of adenoma and healthy subjects and from colon cancer and matched normal tissues was analyzed to determine the microbiota composition (using 16S rDNA) and genomic content (metagenomics). Metagenomic functions with discriminative power between healthy and neoplastic specimens were established. Quantitative Polymerase Chain Reaction (q-PCR) using primers and probes specific to Streptococcus sp. VT_162 were used to validate this bacterium association with neoplastic transformation in stool samples from two independent cohorts of African Americans and Chinese patients with colorectal lesions. The metabolomic analysis of adenomas revealed low amino acids content. The microbiota in both cancer vs. normal tissues and adenoma vs. normal stool samples were different at the 16S rRNA gene level. Cross-mapping of metagenomic data led to 9 markers with significant discriminative power between normal and diseased specimens. These markers identified with Streptococcus sp. VT_162. Q-PCR data showed a statistically significant presence of this bacterium in advanced adenoma and cancer samples in an independent cohort of CRC patients. We defined metagenomic functions from Streptococcus sp. VT_162 with discriminative power among cancers vs. matched normal and adenomas vs. healthy subjects’ stools. Streptococcus sp. VT_162 specific 16S rDNA was validated in an independent cohort. These findings might facilitate non-invasive screening for colorectal cancer. PMID:29120399

  20. Effect of defibrillation threshold testing on effectiveness of the subcutaneous implantable cardioverter defibrillator.

    PubMed

    Peddareddy, Lakshmi; Merchant, Faisal M; Leon, Angel R; Smith, Paige; Patel, Akshar; El-Chami, Mikhael F

    2018-06-12

    Defibrillation threshold (DFT) testing is recommended with the subcutaneous ICD (SICD). To describe first shock efficacy for appropriate SICD therapies stratified by the presence of implant DFT testing. We reviewed all patients receiving SICDs at our institution and stratified them based on whether implant DFT testing was performed. Appropriate shocks were reviewed to see if ventricular tachycardia/ventricular fibrillation (VT/VF) terminated with a single shock. First shock efficacy was stratified by implant DFT status. 178 patients implanted with SICDs and followed in our center were included in this study. Of these, 135 (76 %) underwent DFT testing (DFT (+) group). In the DFT (+) 80 appropriate shocks were needed to treat 69 episodes of VT/VF. The first shock was effective in 61 out of 69 episodes (88.4 %), whereas multiple shocks were required to terminate VT/VF in the remaining 8 episodes. Among 43 patients without implant DFT testing (DFT (-) group), 20 appropriate shocks to treat 17 episodes of VT/VF occurred in 7 patients. VT/VF was successfully terminated with the first shock in 16 out of 17 episodes (first shock efficacy 94.1 %). There was no significant difference in first shock effectiveness between those with and without implant DFT testing (p = 0.97). A strategy that omits DFT testing at implant did not appear to compromise the effictiveness of the SICD. These data suggest that routine DFT testing at SICD implant might not be necessary. Randomized trials are needed to confirm this finding. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  1. Effective dominance of resistance of Spodoptera frugiperda to Bt maize and cotton varieties: implications for resistance management

    NASA Astrophysics Data System (ADS)

    Horikoshi, Renato J.; Bernardi, Daniel; Bernardi, Oderlei; Malaquias, José B.; Okuma, Daniela M.; Miraldo, Leonardo L.; Amaral, Fernando S. De A. E.; Omoto, Celso

    2016-10-01

    The resistance of fall armyworm (FAW), Spodoptera frugiperda, has been characterized to some Cry and Vip3A proteins of Bacillus thuringiensis (Bt) expressed in transgenic maize in Brazil. Here we evaluated the effective dominance of resistance based on the survival of neonates from selected Bt-resistant, heterozygous, and susceptible (Sus) strains of FAW on different Bt maize and cotton varieties. High survival of strains resistant to the Cry1F (HX-R), Cry1A.105/Cry2Ab (VT-R) and Cry1A.105/Cry2Ab/Cry1F (PW-R) proteins was detected on Herculex, YieldGard VT PRO and PowerCore maize. Our Vip3A-resistant strain (Vip-R) exhibited high survival on Herculex, Agrisure Viptera and Agrisure Viptera 3 maize. However, the heterozygous from HX-R × Sus, VT-R × Sus, PW-R × Sus and Vip-R × Sus had complete mortality on YieldGard VT PRO, PowerCore, Agrisure Viptera, and Agrisure Viptera 3, whereas the HX-R × Sus and Vip-R × Sus strains survived on Herculex maize. On Bt cotton, the HX-R, VT-R and PW-R strains exhibited high survival on Bollgard II. All resistant strains survived on WideStrike, but only PW-R and Vip-R × Sus survived on TwinLink. Our study provides useful data to aid in the understanding of the effectiveness of the refuge strategy for Insect Resistance Management of Bt plants.

  2. High-resolution Fourier transform synchrotron spectroscopy of the C-S stretching band of methyl mercaptan, CH332SH

    NASA Astrophysics Data System (ADS)

    Lees, R. M.; Xu, Li-Hong; Billinghurst, B. E.

    2016-01-01

    The C-S stretching fundamental band of 12CH332SH, the principal isotopologue of methyl mercaptan, has been investigated by Fourier transform infrared spectroscopy on the Far-Infrared beamline at the Canadian Light Source synchrotron. The band is centered around 710 cm-1 and shows well-resolved a-type parallel structure. Most of the A and E spectral sub-bands have been assigned up to K = 12 for the vt = 0 torsional state and K = 9 for the vt = 1 state, along with a smaller variety of sub-bands for vt = 2. C-S stretching energy term values have been determined employing known ground-state energies, and have been fitted to series expansions in powers of J(J + 1) to determine the substate origins. The origins have in turn been fitted to a Fourier model to characterize the oscillatory torsional energy structure of the C-S stretching state. The amplitude of oscillation of the vt = 0 torsional curves is significantly larger for the C-S stretch state compared to the ground state. A strategy devised to relate this amplitude to an effective torsional barrier height indicates a decrease of about 7% in the effective V3 for the C-S stretch. The vibrational frequency determined for the stretching fundamental from the Fourier fit is 710.3 cm-1. The C-S stretching manifold is crossed by excited vt = 4 torsional levels of the ground state, and strong torsion-vibrational resonant coupling is observed via perturbations in the spectrum together with forbidden sub-bands induced by mixing and intensity borrowing.

  3. SELECTED CHARACTERISTICS OF OCCUPATIONS (PHYSICAL DEMANDS, WORKING CONDITIONS, TRAINING TIME), A SUPPLEMENT TO THE DICTIONARY OF OCCUPATIONAL TITLES.

    ERIC Educational Resources Information Center

    Bureau of Employment Security (DOL), Washington, DC.

    THIS SUPPLEMENT LISTS INDIVIDUAL PHYSICAL DEMANDS, WORKING CONDITIONS, AND TRAINING TIME DATA FOR EACH JOB DEFINED IN VOLUMES 1 AND 2 (VT 003 654 AND VT 003 655). IT WAS PUBLISHED IN RESPONSE TO THE SPECIAL NEEDS OF ORGANIZATIONS AND INDIVIDUALS CONCERNED WITH MANPOWER UTILIZATION WHO REQUIRE MORE SPECIFIC OCCUPATIONAL CHARACTERISTICS DATA THAN…

  4. An Application of MacLaury's Vantage Theory to Abstract Categories: Identity and the Process of Categorisation

    ERIC Educational Resources Information Center

    Fabiszak, Malgorzata

    2010-01-01

    This paper is an application of Robert E. MacLaury's Vantage Theory (VT) to the analysis of real life spoken discourse. It utilizes Dennis R. Preston's (1994) modification of MacLaury's VT. It elucidates how cognitive processes of coordinate selection and combination contribute to the on-line construction of category membership in the abstract…

  5. Air lateral root pruning affects longleaf pine seedling root system morphology

    Treesearch

    Shi-Jean Susana Sung; Dave Haywood

    2016-01-01

    Longleaf pine (Pinus palustris) seedlings were cultured with air lateral root pruning (side-vented containers, VT) or without (solid-walled containers, SW). Seedling root system morphology and growth were assessed before planting and 8 and 14 months after planting. Although VT seedlings had greater root collar diameter than the SW before planting,...

  6. Relating Time-Dependent Acceleration and Height Using an Elevator

    ERIC Educational Resources Information Center

    Kinser, Jason M.

    2015-01-01

    A simple experiment in relating a time-dependent linear acceleration function to height is explored through the use of a smartphone and an elevator. Given acceleration as a function of time, a(t), the velocity function and position functions are determined through integration as in v(t)=? a(t) dt (1) and x(t)=? v(t) dt. Mobile devices such as…

  7. PEACETIME RADIATION HAZARDS IN THE FIRE SERVICE, BASIC COURSE, RESOURCE MANUAL.

    ERIC Educational Resources Information Center

    BERNDT, WILLIAM

    FOR USE BY FIREMEN AND OTHER EMERGENCY PERSONNEL WHO MAY HAVE TO DEAL WITH FIRES OR SIMILAR EMERGENCIES INVOLVING RADIATION HAZARDS, THIS MANUAL IS CORRELATED WITH THE FOLLOWING INSTRUCTIONAL MATERIALS FOR THE 15-HOUR COURSE -- (1) AN INSTRUCTOR'S GUIDE (VT 002 117), (2) A STUDENT STUDY GUIDE (VT 001 878), AND (3) A SET OF TWENTY-TWO 20- BY…

  8. Wave Energy Prize - 1/50th Testing - Advanced Ocean Energy @ VT

    DOE Data Explorer

    Wesley Scharmen

    2016-01-29

    This submission of data includes all the 1/50th scale testing data completed on the Wave Energy Prize for the for the Advanced Ocean Energy @VT team, and includes: 1/50th test data (raw & processed) 1/50th test data video and pictures 1/50th Test plans and testing documents SSTF_Submission (summarized results)

  9. A STUDY OF THE LUMBER INDUSTRY IN IDAHO, PART II.

    ERIC Educational Resources Information Center

    LOUDERMILK, KENNETH M.

    A MORE FORMAL STUDY OF THE LUMBER INDUSTRY (SEE VT 002 152 AND VT 002 153) RESULTED IN IMPRESSIONS OF THE WORKERS AND WORKING CONDITIONS. THERE ARE TWO GENERAL TYPES OF EMPLOYEE--(1) THOSE VIEWING LUMBERING AS STOPGAP EMPLOYMENT WHICH SERVES AS A SOURCE OF WAGES FOR EDUCATIONAL PURPOSES OR AS AN INTERIM JOB WHILE BETTER EMPLOYMENT IS SOUGHT, AND…

  10. Teaching Heliophysics Science to Undergraduates in an Engineering Context

    NASA Astrophysics Data System (ADS)

    Baker, J. B.; Sweeney, D. G.; Ruohoniemi, J.

    2013-12-01

    In recent years, space research at Virginia Tech has experienced rapid growth since the initiation of the Center for Space Science and Engineering Research (Space@VT) during the summer of 2007. The Space@VT center resides in the College of Engineering and currently comprises approximately 30-40 faculty and students. Space@VT research encompasses a wide spectrum of science and engineering activities including: magnetosphere-ionosphere data analysis; ground- and space-based instrument development; spacecraft design and environmental interactions; and numerical space plasma simulations. In this presentation, we describe how Space@VT research is being integrated into the Virginia Tech undergraduate engineering curriculum via classroom instruction and hands-on group project work. In particular, we describe our experiences teaching a new sophomore course titled 'Exploration of the Space Environment' which covers a broad range of scientific, engineering, and societal aspects associated with the exploration and technological exploitation of space. Topics covered include: science of the space environment; space weather hazards and societal impacts; elementary orbital mechanics and rocket propulsion; spacecraft engineering subsystems; and applications of space-based technologies. We also describe a high-altitude weather balloon project which has been offered as a 'hands-on' option for fulfilling the course project requirements of the course.

  11. V-T theory for the self-intermediate scattering function in a monatomic liquid

    NASA Astrophysics Data System (ADS)

    Wallace, Duane C.; Chisolm, Eric D.; De Lorenzi-Venneri, Giulia

    2017-02-01

    In V-T theory the atomic motion is harmonic vibrations in a liquid-specific potential energy valley, plus transits, which move the system rapidly among the multitude of such valleys. In its first application to the self intermediate scattering function (SISF), V-T theory produced an accurate account of molecular dynamics (MD) data at all wave numbers q and time t. Recently, analysis of the mean square displacement (MSD) resolved a crossover behavior that was not observed in the SISF study. Our purpose here is to apply the more accurate MSD calibration to the SISF, and assess the results. We derive and discuss the theoretical equations for vibrational and transit contributions to the SISF. The time evolution is divided into three successive intervals: the vibrational interval when the vibrational contribution alone accurately accounts for the MD data; the crossover when the vibrational contribution saturates and the transit contribution becomes resolved; and the diffusive interval when the transit contribution alone accurately accounts for the MD data. The resulting theoretical error is extremely small at all q and t. V-T theory is compared to mode-coupling theories for the MSD and SISF, and to recent developments in Brownian motion experiments and theory.

  12. Studies on impact of electron cyclotron wave injection on the internal transport barriers in JT-60U weak shear plasmas

    NASA Astrophysics Data System (ADS)

    Ide, S.; Takenaga, H.; Isayama, A.; Sakamoto, Y.; Yoshida, M.; Gormezano, C.

    2007-11-01

    Impact of the electron cyclotron range of frequency wave (ECRF) on the internal transport barriers (ITBs) in a weak shear (WS) plasma has been investigated in JT-60U. The fundamental O-mode ECRF of 110 GHz injected obliquely (co-current drive) from the low field side is used. It is observed that the ion temperature (Ti) ITB in a WS plasma can be degraded by ECRF. It is clarified for the first time that the degradation depends increasingly on the EC power (PEC) but decreasingly on the plasma current (Ip). Moreover it is confirmed that ECRF affects the toroidal rotation (Vt) indirectly and results in the flattening of Vt(ρ) and therefore the radial electric field (Er) profiles regardless of the direction of the target Vt(ρ), peaking co or counter direction (relative to the Ip direction). Furthermore, it is recently found that Ti and Vt in the whole ITB region are affected with almost no delay from the EC onset even with off-axis EC deposition. These results indicate that EC injection unveiled a semi-global structure that characterizes Ti ITB in a WS plasma.

  13. Anaerobic threshold determination through ventilatory and electromyographics parameters.

    PubMed

    Gassi, E R; Bankoff, A D P

    2010-01-01

    The aim of present study was to compare the alterations in electromyography signs with Ventilatory Threshold (VT). Had been part of the study eight men, amateur cyclists and triathletes (25.25 +/- 6.96 years), that they had exercised themselves in a mechanical cicloergometer, a cadence of 80 RPM and with the increased intensity being in 25 W/min until the exhaustion. The VT was determined by a non-linear increase in VE/VO2 without any increase in VE/VCO2 and compared with the intensity corresponding to break point of amplitude EMG sign during the incremental exercise. The EMG--Fatigue Threshold (FT) and Ventilatory Threshold (VT) parameters used were the power, the time, absolute and relative VO2, ventilation (VE), the heart hate (HH) and the subjective perception of the effort. The results had not shown to difference in none of the variable selected for the corresponding intensity to VT and FT--EMG of the muscles lateralis vastus and femoris rectus. The parameters used in the comparison between the electromyographic indicators and ventilatory were the load, the time, absolute VO2 and relative to corporal mass, to ventilation (VE), the heart frequency (HH) and the Subjective Perception of the Effort (SPE).

  14. Effects of various gate materials on electrical degradation of a-Si:H TFT in industrial display application

    NASA Astrophysics Data System (ADS)

    Ho, Ching-Yuan; Chang, Yaw-Jen

    2016-02-01

    Both aluminum (Al) and copper (Cu), acting as transmission lines in the hydrogenated amorphous silicon of a thin film transistor (a-Si:H TFT), were studied to investigate electrical degradation including electron-migration (EM) and threshold voltage (Vt) stability and recovery performance. Under long-term current stress, the Cu material exhibited excellent resistance to EM properties, but a passivated SiNx crack was observed due to fast heat conductivity. By applying electrical stress on the gate and drain for 5 × 104 s, the power-law time dependency of the threshold voltage shift (ΔVt) indicated that the defective state creation dominated the TFT device's instability. The presence of drain stress increased the overall ΔVt because the high longitudinal field induced impact ionization and then, enhanced hot-carrier-induced electron trapping within the gate SiNx dielectric. An annealing effect prompted a stressed a-Si:H TFT back to virgin status. This study proposes better ΔVt stability and excellent resistance against electron-migration in a Cu gate device which can be considered as a candidate for a transmission line on prolonged TFT applications.

  15. A vertebrate retina with segregated colour and polarization sensitivity.

    PubMed

    Novales Flamarique, Iñigo

    2017-09-13

    Besides colour and intensity, some invertebrates are able to independently detect the polarization of light. Among vertebrates, such separation of visual modalities has only been hypothesized for some species of anchovies whose cone photoreceptors have unusual ultrastructure that varies with retinal location. Here, I tested this hypothesis by performing physiological experiments of colour and polarization discrimination using the northern anchovy, Engraulis mordax Optic nerve recordings showed that the ventro-temporal (VT), but not the ventro-nasal (VN), retina was polarization sensitive, and this coincided with the exclusive presence of polarization-sensitive photoreceptors in the VT retina. Spectral (colour) sensitivity recordings from the VN retina indicated the contribution of two spectral cone mechanisms to the optic nerve response, whereas only one contributed to the VT retina. This was supported by the presence of only one visual pigment in the VT retina and two in the VN retina, suggesting that only the VN retina was associated with colour sensitivity. Behavioural tests further demonstrated that anchovies could discriminate colour and the polarization of light using the ventral retina. Thus, in analogy with the visual system of some invertebrates, the northern anchovy has a retina with segregated retinal pathways for colour and polarization vision. © 2017 The Author(s).

  16. Buffer Layer Doping Concentration Measurement Using VT-VSUB Characteristics of GaN HEMT with p-GaN Substrate Layer

    NASA Astrophysics Data System (ADS)

    Hu, Cheng-Yu; Nakatani, Katsutoshi; Kawai, Hiroji; Ao, Jin-Ping; Ohno, Yasuo

    To improve the high voltage performance of AlGaN/GaN heterojunction field effect transistors (HFETs), we have fabricated AlGaN/GaN HFETs with p-GaN epi-layer on sapphire substrate with an ohmic contact to the p-GaN (p-sub HFET). Substrate bias dependent threshold voltage variation (VT-VSUB) was used to directly determine the doping concentration profile in the buffer layer. This VT-VSUB method was developed from Si MOSFET. For HFETs, the insulator is formed by epitaxially grown and heterogeneous semiconductor layer while for Si MOSFETs the insulator is amorphous SiO2. Except that HFETs have higher channel mobility due to the epitaxial insulator/semiconductor interface, HFETs and Si MOSFETs are basically the same in the respect of device physics. Based on these considerations, the feasibility of this VT-VSUB method for AlGaN/GaN HFETs was discussed. In the end, the buffer layer doping concentration was measured to be 2 × 1017cm-3, p-type, which is well consistent with the Mg concentration obtained from secondary ion mass spectroscopy (SIMS) measurement.

  17. Menstrual cycle characteristics as determinants of plasma concentrations of perfluoroalkyl substances (PFASs) in the Norwegian Mother and Child Cohort (MoBa study).

    PubMed

    Singer, Alison B; Whitworth, Kristina W; Haug, Line S; Sabaredzovic, Azemira; Impinen, Antti; Papadopoulou, Eleni; Longnecker, Matthew P

    2018-06-04

    Perfluoroalkyl substances (PFASs) are fluorinated organic compounds that have been used in a variety of industrial and consumer applications. Menstruation is implicated as a possible route of elimination for PFASs in women. The overall purpose of this study was to examine menstrual cycle characteristics as determinants of plasma PFAS concentrations in women. Our study sample consisted of 1977 pregnant women from the Norwegian Mother and Child Cohort (MoBa) study. The women were asked about menstrual cycle regularity in the year before the pregnancy and typical menstrual cycle length as well as other demographic and reproductive characteristics in a questionnaire completed during the pregnancy. Blood samples were collected around 17-18 weeks gestation and PFAS concentrations were measured in plasma. We examined the association between menstrual cycle characteristics and seven PFASs (perfluorooctanoic acid (PFOA), perfluorononanoic acid (PFNA), perfluorodecanoic acid (PFDA), perfluoroundecanoic acid (PFUnDA), perfluorohexane sulfonate (PFHxS), perfluoroheptane sulfonate (PFHpS), and perfluorooctane sulfonate (PFOS)) using multiple linear regression, adjusted for age, pre-pregnancy body mass index, smoking, education, income, parity, oral contraceptive use, inter-pregnancy interval, and breastfeeding duration. Irregular cycles were not associated with PFAS concentrations. Overall, we found no evidence of associations between menstrual cycle length and PFAS concentrations. In subgroup analyses we found some evidence, among parous women, of decreased PFHpS and PFOS with short menstrual cycles; we also found, among recent OC users (in the 12 months before the questionnaire) increased PFNA and PFUnDA with long cycle length. Limitations of our study include misclassification of menstrual cycle characteristics, small sample sizes in the sub-group analyses, and a lack of information on duration and volume of menses. In the entire study sample, we found little evidence of menstrual cycle characteristics as determinants of PFAS concentrations. However, we observed some associations between cycle length and PFAS concentrations with some select PFAS compounds in subgroup analyses. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Beat-to-Beat Variation in Periodicity of Local Calcium Releases Contributes to Intrinsic Variations of Spontaneous Cycle Length in Isolated Single Sinoatrial Node Cells

    PubMed Central

    Monfredi, Oliver; Maltseva, Larissa A.; Spurgeon, Harold A.; Boyett, Mark R.; Lakatta, Edward G.; Maltsev, Victor A.

    2013-01-01

    Spontaneous, submembrane local Ca2+ releases (LCRs) generated by the sarcoplasmic reticulum in sinoatrial nodal cells, the cells of the primary cardiac pacemaker, activate inward Na+/Ca2+-exchange current to accelerate the diastolic depolarization rate, and therefore to impact on cycle length. Since LCRs are generated by Ca2+ release channel (i.e. ryanodine receptor) openings, they exhibit a degree of stochastic behavior, manifested as notable cycle-to-cycle variations in the time of their occurrence. Aim The present study tested whether variation in LCR periodicity contributes to intrinsic (beat-to-beat) cycle length variability in single sinoatrial nodal cells. Methods We imaged single rabbit sinoatrial nodal cells using a 2D-camera to capture LCRs over the entire cell, and, in selected cells, simultaneously measured action potentials by perforated patch clamp. Results LCRs begin to occur on the descending part of the action potential-induced whole-cell Ca2+ transient, at about the time of the maximum diastolic potential. Shortly after the maximum diastolic potential (mean 54±7.7 ms, n = 14), the ensemble of waxing LCR activity converts the decay of the global Ca2+ transient into a rise, resulting in a late, whole-cell diastolic Ca2+ elevation, accompanied by a notable acceleration in diastolic depolarization rate. On average, cells (n = 9) generate 13.2±3.7 LCRs per cycle (mean±SEM), varying in size (7.1±4.2 µm) and duration (44.2±27.1 ms), with both size and duration being greater for later-occurring LCRs. While the timing of each LCR occurrence also varies, the LCR period (i.e. the time from the preceding Ca2+ transient peak to an LCR’s subsequent occurrence) averaged for all LCRs in a given cycle closely predicts the time of occurrence of the next action potential, i.e. the cycle length. Conclusion Intrinsic cycle length variability in single sinoatrial nodal cells is linked to beat-to-beat variations in the average period of individual LCRs each cycle. PMID:23826247

  19. Evaluation of a turbine flow meter (Ventilometer Mark 2) in the measurement of ventilation.

    PubMed

    Cooper, C B; Harris, N D; Howard, P

    1990-01-01

    We have evaluated a turbine flow meter (Ventilometer Mark 2, PK Morgan, Kent, UK) at low flow rates and levels of ventilation which are likely to be encountered during exercise in patients with chronic respiratory disease. Pulsatile flows were generated from a volume-cycled mechanical ventilator, the flow wave-form was modified by damping to simulate a human breathing pattern. Comparative measurements of ventilation were made whilst varying tidal volume (VT) from 0.22 to 1.131 and respiratory rate (fR) from 10 to 35 min-1. At lower levels of ventilation the instrument tended to underread especially with increasing fR. The calibration factor must be adjusted to match the level of ventilation if the measurement errors are to be within 5%.

  20. Measurements of entanglement over a kilometric distance to test superluminal models of Quantum Mechanics: preliminary results.

    NASA Astrophysics Data System (ADS)

    Cocciaro, B.; Faetti, S.; Fronzoni, L.

    2017-08-01

    As shown in the EPR paper (Einstein, Podolsky e Rosen, 1935), Quantum Mechanics is a non-local Theory. The Bell theorem and the successive experiments ruled out the possibility of explaining quantum correlations using only local hidden variables models. Some authors suggested that quantum correlations could be due to superluminal communications that propagate isotropically with velocity vt > c in a preferred reference frame. For finite values of vt and in some special cases, Quantum Mechanics and superluminal models lead to different predictions. So far, no deviations from the predictions of Quantum Mechanics have been detected and only lower bounds for the superluminal velocities vt have been established. Here we describe a new experiment that increases the maximum detectable superluminal velocities and we give some preliminary results.

  1. PARAVT: Parallel Voronoi tessellation code

    NASA Astrophysics Data System (ADS)

    González, R. E.

    2016-10-01

    In this study, we present a new open source code for massive parallel computation of Voronoi tessellations (VT hereafter) in large data sets. The code is focused for astrophysical purposes where VT densities and neighbors are widely used. There are several serial Voronoi tessellation codes, however no open source and parallel implementations are available to handle the large number of particles/galaxies in current N-body simulations and sky surveys. Parallelization is implemented under MPI and VT using Qhull library. Domain decomposition takes into account consistent boundary computation between tasks, and includes periodic conditions. In addition, the code computes neighbors list, Voronoi density, Voronoi cell volume, density gradient for each particle, and densities on a regular grid. Code implementation and user guide are publicly available at https://github.com/regonzar/paravt.

  2. Distribution of shortest cycle lengths in random networks

    NASA Astrophysics Data System (ADS)

    Bonneau, Haggai; Hassid, Aviv; Biham, Ofer; Kühn, Reimer; Katzav, Eytan

    2017-12-01

    We present analytical results for the distribution of shortest cycle lengths (DSCL) in random networks. The approach is based on the relation between the DSCL and the distribution of shortest path lengths (DSPL). We apply this approach to configuration model networks, for which analytical results for the DSPL were obtained before. We first calculate the fraction of nodes in the network which reside on at least one cycle. Conditioning on being on a cycle, we provide the DSCL over ensembles of configuration model networks with degree distributions which follow a Poisson distribution (Erdős-Rényi network), degenerate distribution (random regular graph), and a power-law distribution (scale-free network). The mean and variance of the DSCL are calculated. The analytical results are found to be in very good agreement with the results of computer simulations.

  3. Radiographic screen-film noise power spectrum: variation with microdensitometer slit length.

    PubMed

    Sandrik, J M; Wagner, R F

    1981-08-15

    When the noise power spectrum (NPS) of a radiographic screen-film system is measured by microdensito-metrically scanning the film with a long narrow slit, sufficient slit length allows estimation of a section of the 2-D NPS from the 1-D film scans; insufficient length causes underestimation of the NPS, particularly at low frequencies ( greater, similar1 cycle/mm). Spectra of Hi-Plus, Par Speed, and Detail screens used with XRP films measured as a function of microdensitometer slit length tended to plateau at long slit lengths. The slit length was considered sufficient when NPS components at 0.4 cycle/mm were within 5% of the plateau. This occurred for slit lengths of at least 4.2, 2.6, and 2.5 mm for Hi-Plus, Par Speed, and Detail systems, respectively.

  4. Feasibility and safety of low-flow extracorporeal carbon dioxide removal to facilitate ultra-protective ventilation in patients with moderate acute respiratory distress sindrome.

    PubMed

    Fanelli, Vito; Ranieri, Marco V; Mancebo, Jordi; Moerer, Onnen; Quintel, Michael; Morley, Scott; Moran, Indalecio; Parrilla, Francisco; Costamagna, Andrea; Gaudiosi, Marco; Combes, Alain

    2016-02-10

    Mechanical ventilation with a tidal volume (VT) of 6 mL/kg/predicted body weight (PBW), to maintain plateau pressure (Pplat) lower than 30 cmH2O, does not completely avoid the risk of ventilator induced lung injury (VILI). The aim of this study was to evaluate safety and feasibility of a ventilation strategy consisting of very low VT combined with extracorporeal carbon dioxide removal (ECCO2R). In fifteen patients with moderate ARDS, VT was reduced from baseline to 4 mL/kg PBW while PEEP was increased to target a plateau pressure--(Pplat) between 23 and 25 cmH2O. Low-flow ECCO2R was initiated when respiratory acidosis developed (pH < 7.25, PaCO2 > 60 mmHg). Ventilation parameters (VT, respiratory rate, PEEP), respiratory compliance (CRS), driving pressure (DeltaP = VT/CRS), arterial blood gases, and ECCO2R system operational characteristics were collected during the period of ultra-protective ventilation. Patients were weaned from ECCO2R when PaO2/FiO2 was higher than 200 and could tolerate conventional ventilation settings. Complications, mortality at day 28, need for prone positioning and extracorporeal membrane oxygenation, and data on weaning from both MV and ECCO2R were also collected. During the 2 h run in phase, VT reduction from baseline (6.2 mL/kg PBW) to approximately 4 mL/kg PBW caused respiratory acidosis (pH < 7.25) in all fifteen patients. At steady state, ECCO2R with an average blood flow of 435 mL/min and sweep gas flow of 10 L/min was effective at correcting pH and PaCO2 to within 10 % of baseline values. PEEP values tended to increase at VT of 4 mL/kg from 12.2 to 14.5 cmH2O, but this change was not statistically significant. Driving pressure was significantly reduced during the first two days compared to baseline (from 13.9 to 11.6 cmH2O; p < 0.05) and there were no significant differences in the values of respiratory system compliance. Rescue therapies for life threatening hypoxemia such as prone position and ECMO were necessary in four and two patients, respectively. Only two study-related adverse events were observed (intravascular hemolysis and femoral catheter kinking). The low-flow ECCO2R system safely facilitates a low volume, low pressure ultra-protective mechanical ventilation strategy in patients with moderate ARDS.

  5. A proposal for unification of fatigue crack growth law

    NASA Astrophysics Data System (ADS)

    Kobelev, V.

    2017-05-01

    In the present paper, the new fractional-differential dependences of cycles to failure for a given initial crack length upon the stress amplitude in the linear fracture approach are proposed. The anticipated unified propagation function describes the infinitesimal crack length growths per increasing number of load cycles, supposing that the load ratio remains constant over the load history. Two unification fractional-differential functions with different number of fitting parameters are proposed. An alternative, threshold formulations for the fractional-differential propagation functions are suggested. The mean stress dependence is the immediate consequence from the considered laws. The corresponding formulas for crack length over the number of cycles are derived in closed form.

  6. Effect of operational cycle time length on nitrogen removal in an alternating oxidation ditch system.

    PubMed

    Mantziaras, I D; Stamou, A; Katsiri, A

    2011-06-01

    This paper refers to nitrogen removal optimization of an alternating oxidation ditch system through the use of a mathematical model and pilot testing. The pilot system where measurements have been made has a total volume of 120 m(3) and consists of two ditches operating in four phases during one cycle and performs carbon oxidation, nitrification, denitrification and settling. The mathematical model consists of one-dimensional mass balance (convection-dispersion) equations based on the IAWPRC ASM 1 model. After the calibration and verification of the model, simulation system performance was made. Optimization is achieved by testing operational cycles and phases with different time lengths. The limits of EU directive 91/271 for nitrogen removal have been used for comparison. The findings show that operational cycles with smaller time lengths can achieve higher nitrogen removals and that an "equilibrium" between phase time percentages in the whole cycle, for a given inflow, must be achieved.

  7. Health impact assessment of cycling network expansions in European cities.

    PubMed

    Mueller, Natalie; Rojas-Rueda, David; Salmon, Maëlle; Martinez, David; Ambros, Albert; Brand, Christian; de Nazelle, Audrey; Dons, Evi; Gaupp-Berghausen, Mailin; Gerike, Regine; Götschi, Thomas; Iacorossi, Francesco; Int Panis, Luc; Kahlmeier, Sonja; Raser, Elisabeth; Nieuwenhuijsen, Mark

    2018-04-01

    We conducted a health impact assessment (HIA) of cycling network expansions in seven European cities. We modeled the association between cycling network length and cycling mode share and estimated health impacts of the expansion of cycling networks. First, we performed a non-linear least square regression to assess the relationship between cycling network length and cycling mode share for 167 European cities. Second, we conducted a quantitative HIA for the seven cities of different scenarios (S) assessing how an expansion of the cycling network [i.e. 10% (S1); 50% (S2); 100% (S3), and all-streets (S4)] would lead to an increase in cycling mode share and estimated mortality impacts thereof. We quantified mortality impacts for changes in physical activity, air pollution and traffic incidents. Third, we conducted a cost-benefit analysis. The cycling network length was associated with a cycling mode share of up to 24.7% in European cities. The all-streets scenario (S4) produced greatest benefits through increases in cycling for London with 1,210 premature deaths (95% CI: 447-1,972) avoidable annually, followed by Rome (433; 95% CI: 170-695), Barcelona (248; 95% CI: 86-410), Vienna (146; 95% CI: 40-252), Zurich (58; 95% CI: 16-100) and Antwerp (7; 95% CI: 3-11). The largest cost-benefit ratios were found for the 10% increase in cycling networks (S1). If all 167 European cities achieved a cycling mode share of 24.7% over 10,000 premature deaths could be avoided annually. In European cities, expansions of cycling networks were associated with increases in cycling and estimated to provide health and economic benefits. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Cycling on Earth, in space, on the Moon.

    PubMed

    di Prampero, P E

    2000-08-01

    The mechanical power for cycling (P(c)) at constant ground speed (s), in the absence of wind on smooth hard terrain is the sum of the power dissipated against rolling resistance, gravity and air resistance: P(c)=a x s + M x g x s x sin gamma + b x S3, where a and b are constants, M is the mass of the subject plus bike, g is the acceleration of gravity and gamma is the angle of the terrain with the horizontal. The constant b depends upon the drag coefficient (Cd), the overall area projected on the frontal plane (A(f)), and the air density (rhoa): b = 0.5 x C(d) x A(f) x rhoa. In turn, rhoa depends on air pressure (P(B)) and temperature (T): rhoa=rho0 x 0.359 x P(B) x T(-1), where rho0 is the air density at 760 mmHg (101.3 kPa) and 273 K. The metabolic power developed by the cyclist (E(c)) is related to P(c) E(c) = P(c) x eta(-1), where eta is the mechanical efficiency of cycling. The experimental values of a, b and eta are fairly well known so that, if the maximal metabolic power as a function of the performance time is known for a given cyclist, the following set of data can be individually calculated: (1) best performances over any given distance and for any given altitude above sea level, (2) the effects of posture and body size on maximal speeds, and (3) the maximal incline of the terrain that can be overcome at any given speed or coasting speed for any given downslope. The above set of information makes it possible also to calculate the characteristics of a "Twin Bikes System" (TBS) for preventing microgravity deconditioning during long-term space flight. The TBS consists of two bicycles that are mechanically coupled by a differential gearing, which move at the very same speed, but in the opposite sense, along the inner wall of a cylindrically shaped space module. The circular trajectories induce a centrifugal acceleration vector (a(c)) oriented along the head-to-feet direction of each subject: a(c) = v(t)2 x r(-1) where v(t) is the tangential velocity and r the radius of gyration, which is equal to the inner radius of the space module. So, any desired value of a(c) can be achieved by appropriately selecting v(t), wherefrom the mechanical and metabolic powers that the astronauts must generate can be readily calculated. Experiments performed in a ground-based human centrifuge have shown that the discomfort derived from the rotating environment is reasonably low and well tolerated. If the appropriate atmospheric pressure is provided, cycling on circular or elliptical tracks may be useful to reduce cardiovascular deconditioning that occurs due to the reduced gravity in permanently manned lunar bases. Indeed, on the curved parts of the path a cyclist will generate a horizontal outward acceleration: a(c) = s2 x r(-1), where s is the velocity along the track and r is the radius of curvature. To counterbalance a(c), the subject plus bike must lean inwards so that the vectorial sum of a(c) plus the lunar gravity (g(L) = 1.62 m x s(-2)) is applied along a straight line that includes the centre of mass of the system and the point of wheel contact with the ground. For values of s from 10 to 20 m x s(-1) and r from 50 to 200 m, this vectorial sum ranges from 1.05 to 5.03 g(L) (0.17-0.83 g).

  9. Incendiary Devices for the in-situ Combustion of Crude Oil Slicks

    DTIC Science & Technology

    1983-01-01

    contiennent. Celles-cl se composent principalement d’un oxydant , le perchlorate d’ammonium, d’un carburant, une poudre m~tallique, et d’un liant...20.8 I- R T: 78% vt. R-45HT/22% wt. DDI-1410. 2- Epoxy: 85% vt. Epon 815/15% wt. Hysol 3543. 3- Solvent: ethyl alcohol . 4- F-ND: boron-potassium nitrate

  10. 75 FR 30280 - Airworthiness Directives; Stemme GmbH & Co. KG Model S10-VT Powered Sailplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-01

    ... metal. Since its publication, another fuel leakage has been reported on a S10-VT which had implemented... Installation of a Stainless Steel T- and Y- Connector in the Fuel System in Lieu of a Zinc Metal T- and Y... fitting instead of the zinc metal connector specified in STEMME F & D Service Bulletin A31-10-083, Am...

  11. Performance of Portable Ventilators at Altitude

    DTIC Science & Technology

    2015-03-30

    collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT...Deploying ventilators that can maintain a consistent tidal volume (VT) delivery at various altitudes is imperative for lung protection when...performance of mechanical ventilators calibrated for operation at sea level. Deploying ventilators that can maintain a consistent tidal volume (VT) delivery

  12. Institutional Research When the Only Constant Is Change. Proceedings of the Annual NEAIR Conference (42nd, Burlington, VT, Oct 31-Nov 3, 2015)

    ERIC Educational Resources Information Center

    Parker, Tiffany, Ed.

    2015-01-01

    The NEAIR 2015 Conference Proceedings is a compilation of papers presented at the Burlington, VT, conference. Papers in this document include:(1) Strategies to Analyze Course and Teaching Evaluation Data (Kati Li); (2) Using a Mixed Methods Approach to Assess a Leadership Mentoring Program (Betty Harper); (3) Flagship Institutions and the Struggle…

  13. Retest imaging of [11C]NOP-1A binding to nociceptin/orphanin FQ peptide (NOP) receptors in the brain of healthy humans.

    PubMed

    Lohith, Talakad G; Zoghbi, Sami S; Morse, Cheryl L; Araneta, Maria D Ferraris; Barth, Vanessa N; Goebl, Nancy A; Tauscher, Johannes T; Pike, Victor W; Innis, Robert B; Fujita, Masahiro

    2014-02-15

    [(11)C]NOP-1A is a novel high-affinity PET ligand for imaging nociceptin/orphanin FQ peptide (NOP) receptors. Here, we report reproducibility and reliability measures of binding parameter estimates for [(11)C]NOP-1A binding in the brain of healthy humans. After intravenous injection of [(11)C]NOP-1A, PET scans were conducted twice on eleven healthy volunteers on the same (10/11 subjects) or different (1/11 subjects) days. Subjects underwent serial sampling of radial arterial blood to measure parent radioligand concentrations. Distribution volume (VT; a measure of receptor density) was determined by compartmental (one- and two-tissue) modeling in large regions and by simpler regression methods (graphical Logan and bilinear MA1) in both large regions and voxel data. Retest variability and intraclass correlation coefficient (ICC) of VT were determined as measures of reproducibility and reliability respectively. Regional [(11)C]NOP-1A uptake in the brain was high, with a peak radioactivity concentration of 4-7 SUV (standardized uptake value) and a rank order of putamen>cingulate cortex>cerebellum. Brain time-activity curves fitted well in 10 of 11 subjects by unconstrained two-tissue compartmental model. The retest variability of VT was moderately good across brain regions except cerebellum, and was similar across different modeling methods, averaging 12% for large regions and 14% for voxel-based methods. The retest reliability of VT was also moderately good in most brain regions, except thalamus and cerebellum, and was similar across different modeling methods averaging 0.46 for large regions and 0.48 for voxels having gray matter probability >20%. The lowest retest variability and highest retest reliability of VT were achieved by compartmental modeling for large regions, and by the parametric Logan method for voxel-based methods. Moderately good reproducibility and reliability measures of VT for [(11)C]NOP-1A make it a useful PET ligand for comparing NOP receptor binding between different subject groups or under different conditions in the same subject. Copyright © 2013. Published by Elsevier Inc.

  14. Vector tomography for reconstructing electric fields with non-zero divergence in bounded domains

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koulouri, Alexandra, E-mail: koulouri@uni-muenster.de; Department of Electrical and Electronic Engineering, Imperial College London, Exhibition Road, London SW7 2BT; Brookes, Mike

    In vector tomography (VT), the aim is to reconstruct an unknown multi-dimensional vector field using line integral data. In the case of a 2-dimensional VT, two types of line integral data are usually required. These data correspond to integration of the parallel and perpendicular projection of the vector field along the integration lines and are called the longitudinal and transverse measurements, respectively. In most cases, however, the transverse measurements cannot be physically acquired. Therefore, the VT methods are typically used to reconstruct divergence-free (or source-free) velocity and flow fields that can be reconstructed solely from the longitudinal measurements. In thismore » paper, we show how vector fields with non-zero divergence in a bounded domain can also be reconstructed from the longitudinal measurements without the need of explicitly evaluating the transverse measurements. To the best of our knowledge, VT has not previously been used for this purpose. In particular, we study low-frequency, time-harmonic electric fields generated by dipole sources in convex bounded domains which arise, for example, in electroencephalography (EEG) source imaging. We explain in detail the theoretical background, the derivation of the electric field inverse problem and the numerical approximation of the line integrals. We show that fields with non-zero divergence can be reconstructed from the longitudinal measurements with the help of two sparsity constraints that are constructed from the transverse measurements and the vector Laplace operator. As a comparison to EEG source imaging, we note that VT does not require mathematical modeling of the sources. By numerical simulations, we show that the pattern of the electric field can be correctly estimated using VT and the location of the source activity can be determined accurately from the reconstructed magnitudes of the field. - Highlights: • Vector tomography is used to reconstruct electric fields generated by dipole sources. • Inverse solutions are based on longitudinal and transverse line integral measurements. • Transverse line integral measurements are used as a sparsity constraint. • Numerical procedure to approximate the line integrals is described in detail. • Patterns of the studied electric fields are correctly estimated.« less

  15. A Feasibility Study for Perioperative Ventricular Tachycardia Prognosis and Detection and Noise Detection Using a Neural Network and Predictive Linear Operators

    NASA Technical Reports Server (NTRS)

    Moebes, T. A.

    1994-01-01

    To locate the accessory pathway(s) in preexicitation syndromes, epicardial and endocardial ventricular mapping is performed during anterograde ventricular activation via accessory pathway(s) from data originally received in signal form. As the number of channels increases, it is pertinent that more automated detection of coherent/incoherent signals is achieved as well as the prediction and prognosis of ventricular tachywardia (VT). Today's computers and computer program algorithms are not good in simple perceptual tasks such as recognizing a pattern or identifying a sound. This discrepancy, among other things, has been a major motivating factor in developing brain-based, massively parallel computing architectures. Neural net paradigms have proven to be effective at pattern recognition tasks. In signal processing, the picking of coherent/incoherent signals represents a pattern recognition task for computer systems. The picking of signals representing the onset ot VT also represents such a computer task. We attacked this problem by defining four signal attributes for each potential first maximal arrival peak and one signal attribute over the entire signal as input to a back propagation neural network. One attribute was the predicted amplitude value after the maximum amplitude over a data window. Then, by using a set of known (user selected) coherent/incoherent signals, and signals representing the onset of VT, we trained the back propagation network to recognize coherent/incoherent signals, and signals indicating the onset of VT. Since our output scheme involves a true or false decision, and since the output unit computes values between 0 and 1, we used a Fuzzy Arithmetic approach to classify data as coherent/incoherent signals. Furthermore, a Mean-Square Error Analysis was used to determine system stability. The neural net based picking coherent/incoherent signal system achieved high accuracy on picking coherent/incoherent signals on different patients. The system also achieved a high accuracy of picking signals which represent the onset of VT, that is, VT immediately followed these signals. A special binary representation of the input and output data allowed the neural network to train very rapidly as compared to another standard decimal or normalized representations of the data.

  16. Inconsistent shock advisories for monomorphic VT and Torsade de Pointes--A prospective experimental study on AEDs and defibrillators.

    PubMed

    Fitzgerald, Abi; Johnson, Meshell; Hirsch, Jan; Rich, Mary-Ann; Fidler, Richard

    2015-07-01

    Cardiovascular disease and sudden cardiac arrest are the leading causes of death in the United States. Early defibrillation is key to successful resuscitation for patients who experience shockable rhythms during a cardiac arrest. It is therefore vital that the shock advisory of AEDs (automated external defibrillators) or defibrillators in AED mode be reliable and appropriate. The goal of this study was to better understand the performance of multiple lay-rescuer and hospital professional defibrillators in AED mode in their analysis of ventricular arrhythmias. The measurable objectives of this study sought to quantify: 1. No shock advisory for sinus rhythms at any rate. 2. Recognition and shock advisory for ventricular fibrillation (VF). 3. Recognition and shock advisory for monomorphic ventricular tachycardia (VT). 4. Recognition and shock advisory for Torsades de Pointes (TdP). This is a prospective evaluation of two AEDs and four semi-automatic, hospital professional defibrillators. This study represents post-marketing evaluation of FDA approved devices. Each defibrillator was connected to multiple rhythm simulators and presented with simulated ECG waveforms 20 consecutive times at various rates when possible. All four defibrillators and both AEDs tested consistently recognized normal sinus rhythm (NSR) from all rhythm sources, and did not recommend a shock for NSR at any rate (from 80 to 220 bpm). All four defibrillators and both AEDs recognized VF from all rhythm sources tested and recommended a shock 100% of the time. Variations were found in the shock advisory rates among defibrillators when testing simulated VT heart rates at or below 150 bpm. One AED tested did not consistently advise a shock for monomorphic VT or TdP at any tested rate. Lay-rescuer AEDs and professional hospital defibrillators tested in AED mode did not reliably recommend a shock for sustained monomorphic VT or TdP at certain rates, despite the fact that it is a critical component of the currently recommended treatment. These findings require further examination of the risk benefit analysis of shocking or not shocking rhythms such as TdP or pulseless VT. Published by Elsevier Ireland Ltd.

  17. Driving pressure and survival in the acute respiratory distress syndrome.

    PubMed

    Amato, Marcelo B P; Meade, Maureen O; Slutsky, Arthur S; Brochard, Laurent; Costa, Eduardo L V; Schoenfeld, David A; Stewart, Thomas E; Briel, Matthias; Talmor, Daniel; Mercat, Alain; Richard, Jean-Christophe M; Carvalho, Carlos R R; Brower, Roy G

    2015-02-19

    Mechanical-ventilation strategies that use lower end-inspiratory (plateau) airway pressures, lower tidal volumes (VT), and higher positive end-expiratory pressures (PEEPs) can improve survival in patients with the acute respiratory distress syndrome (ARDS), but the relative importance of each of these components is uncertain. Because respiratory-system compliance (CRS) is strongly related to the volume of aerated remaining functional lung during disease (termed functional lung size), we hypothesized that driving pressure (ΔP=VT/CRS), in which VT is intrinsically normalized to functional lung size (instead of predicted lung size in healthy persons), would be an index more strongly associated with survival than VT or PEEP in patients who are not actively breathing. Using a statistical tool known as multilevel mediation analysis to analyze individual data from 3562 patients with ARDS enrolled in nine previously reported randomized trials, we examined ΔP as an independent variable associated with survival. In the mediation analysis, we estimated the isolated effects of changes in ΔP resulting from randomized ventilator settings while minimizing confounding due to the baseline severity of lung disease. Among ventilation variables, ΔP was most strongly associated with survival. A 1-SD increment in ΔP (approximately 7 cm of water) was associated with increased mortality (relative risk, 1.41; 95% confidence interval [CI], 1.31 to 1.51; P<0.001), even in patients receiving "protective" plateau pressures and VT (relative risk, 1.36; 95% CI, 1.17 to 1.58; P<0.001). Individual changes in VT or PEEP after randomization were not independently associated with survival; they were associated only if they were among the changes that led to reductions in ΔP (mediation effects of ΔP, P=0.004 and P=0.001, respectively). We found that ΔP was the ventilation variable that best stratified risk. Decreases in ΔP owing to changes in ventilator settings were strongly associated with increased survival. (Funded by Fundação de Amparo e Pesquisa do Estado de São Paulo and others.).

  18. Modeling the influence of genetic and environmental variation on the expression of plant life cycles across landscapes.

    PubMed

    Burghardt, Liana T; Metcalf, C Jessica E; Wilczek, Amity M; Schmitt, Johanna; Donohue, Kathleen

    2015-02-01

    Organisms develop through multiple life stages that differ in environmental tolerances. The seasonal timing, or phenology, of life-stage transitions determines the environmental conditions to which each life stage is exposed and the length of time required to complete a generation. Both environmental and genetic factors contribute to phenological variation, yet predicting their combined effect on life cycles across a geographic range remains a challenge. We linked submodels of the plasticity of individual life stages to create an integrated model that predicts life-cycle phenology in complex environments. We parameterized the model for Arabidopsis thaliana and simulated life cycles in four locations. We compared multiple "genotypes" by varying two parameters associated with natural genetic variation in phenology: seed dormancy and floral repression. The model predicted variation in life cycles across locations that qualitatively matches observed natural phenology. Seed dormancy had larger effects on life-cycle length than floral repression, and results suggest that a genetic cline in dormancy maintains a life-cycle length of 1 year across the geographic range of this species. By integrating across life stages, this approach demonstrates how genetic variation in one transition can influence subsequent transitions and the geographic distribution of life cycles more generally.

  19. Modeling Menstrual Cycle Length and Variability at the Approach of Menopause Using Hierarchical Change Point Models

    PubMed Central

    Huang, Xiaobi; Elliott, Michael R.; Harlow, Siobán D.

    2013-01-01

    SUMMARY As women approach menopause, the patterns of their menstrual cycle lengths change. To study these changes, we need to jointly model both the mean and variability of cycle length. Our proposed model incorporates separate mean and variance change points for each woman and a hierarchical model to link them together, along with regression components to include predictors of menopausal onset such as age at menarche and parity. Additional complexity arises from the fact that the calendar data have substantial missingness due to hormone use, surgery, and failure to report. We integrate multiple imputation and time-to event modeling in a Bayesian estimation framework to deal with different forms of the missingness. Posterior predictive model checks are applied to evaluate the model fit. Our method successfully models patterns of women’s menstrual cycle trajectories throughout their late reproductive life and identifies change points for mean and variability of segment length, providing insight into the menopausal process. More generally, our model points the way toward increasing use of joint mean-variance models to predict health outcomes and better understand disease processes. PMID:24729638

  20. On the Importance of Cycle Minimum in Sunspot Cycle Prediction

    NASA Technical Reports Server (NTRS)

    Wilson, Robert M.; Hathaway, David H.; Reichmann, Edwin J.

    1996-01-01

    The characteristics of the minima between sunspot cycles are found to provide important information for predicting the amplitude and timing of the following cycle. For example, the time of the occurrence of sunspot minimum sets the length of the previous cycle, which is correlated by the amplitude-period effect to the amplitude of the next cycle, with cycles of shorter (longer) than average length usually being followed by cycles of larger (smaller) than average size (true for 16 of 21 sunspot cycles). Likewise, the size of the minimum at cycle onset is correlated with the size of the cycle's maximum amplitude, with cycles of larger (smaller) than average size minima usually being associated with larger (smaller) than average size maxima (true for 16 of 22 sunspot cycles). Also, it was found that the size of the previous cycle's minimum and maximum relates to the size of the following cycle's minimum and maximum with an even-odd cycle number dependency. The latter effect suggests that cycle 23 will have a minimum and maximum amplitude probably larger than average in size (in particular, minimum smoothed sunspot number Rm = 12.3 +/- 7.5 and maximum smoothed sunspot number RM = 198.8 +/- 36.5, at the 95-percent level of confidence), further suggesting (by the Waldmeier effect) that it will have a faster than average rise to maximum (fast-rising cycles have ascent durations of about 41 +/- 7 months). Thus, if, as expected, onset for cycle 23 will be December 1996 +/- 3 months, based on smoothed sunspot number, then the length of cycle 22 will be about 123 +/- 3 months, inferring that it is a short-period cycle and that cycle 23 maximum amplitude probably will be larger than average in size (from the amplitude-period effect), having an RM of about 133 +/- 39 (based on the usual +/- 30 percent spread that has been seen between observed and predicted values), with maximum amplitude occurrence likely sometime between July 1999 and October 2000.

  1. Electrocardiographic signal-averaging during atrial pacing and effect of cycle length on the terminal QRS in patients with and without inducible ventricular tachycardia.

    PubMed

    Kremers, M S; Black, W H; Lange, R; Wells, P J; Solo, M

    1990-11-01

    Electrocardiographic signal-averaging during sinus rhythm (61 to 99 beats/min) and atrial pacing (100 to 171 beats/min) were performed to determine the effect of heart rate on late potentials in 15 patients without (group 1) and 7 patients with (group 2) inducible sustained ventricular tachycardia (VT). In sinus rhythm (79 +/- 12 vs 77 +/- 12 beats/min, difference not significant), the duration of the low-amplitude signal less than 40 microV was longer in group 2 than group 1 (43 +/- 21 vs 26 +/- 8 ms, p = 0.034) and more patients had late potentials (57 vs 7%, p = 0.021), but QRS duration (121 +/- 32 vs 98 +/- 19 ms) and terminal voltage (33 +/- 33 vs 50 +/- 26 ms) were not significantly different. With atrial pacing in group 1 (128 +/- 16 beats/min), 3 patients developed a simultaneous decrease in terminal voltage and an increase in terminal QRS duration consistent with a late potential, but mean total and terminal durations were unchanged. Terminal voltage increased (50 +/- 26 to 59 +/- 40) but not significantly. With atrial pacing in group 2 (119 +/- 12 beats/min) all patients either had a late potential or developed a simultaneous decrease in terminal voltage and an increase in terminal QRS duration (p = 0.001 vs group 1). Root mean square (p = 0.001 vs group 1). Root mean square voltage decreased (33 +/- 23 to 22 +/- 23) and became significantly different from group 1 (p = 0.017). Mean QRS duration, root mean square terminal voltage and low-amplitude terminal QRS duration, however, were unchanged.(ABSTRACT TRUNCATED AT 250 WORDS)

  2. Competition Between Two Large-Amplitude Motion Models: New Hybrid Hamiltonian Versus Old Pure-Tunneling Hamiltonian

    NASA Astrophysics Data System (ADS)

    Kleiner, Isabelle; Hougen, Jon T.

    2017-06-01

    In this talk we report on our progress in trying to make the hybrid Hamiltonian competitive with the pure-tunneling Hamiltonian for treating large-amplitude motions in methylamine. A treatment using the pure-tunneling model has the advantages of: (i) requiring relatively little computer time, (ii) working with relatively uncorrelated fitting parameters, and (iii) yielding in the vast majority of cases fits to experimental measurement accuracy. These advantages are all illustrated in the work published this past year on a gigantic v_{t} = 1 data set for the torsional fundamental band in methyl amine. A treatment using the hybrid model has the advantages of: (i) being able to carry out a global fit involving both v_{t} = 0 and v_{t} = 1 energy levels and (ii) working with fitting parameters that have a clearer physical interpretation. Unfortunately, a treatment using the hybrid model has the great disadvantage of requiring a highly correlated set of fitting parameters to achieve reasonable fitting accuracy, which complicates the search for a good set of molecular fitting parameters and a fit to experimental accuracy. At the time of writing this abstract, we have been able to carry out a fit with J up to 15 that includes all available infrared data in the v_{t} = 1-0 torsional fundamental band, all ground-state microwave data with K up to 10 and J up to 15, and about a hundred microwave lines within the v_{t} = 1 torsional state, achieving weighted root-mean-square (rms) deviations of about 1.4, 2.8, and 4.2 for these three categories of data. We will give an update of this situation at the meeting. I. Gulaczyk, M. Kreglewski, V.-M. Horneman, J. Mol. Spectrosc., in Press (2017).

  3. Decreased Radiation Exposure and Increased Efficacy in Extracorporeal Lithotripsy Using a New Ultrasound Stone Locking System.

    PubMed

    Abid, Nadia; Ravier, Emmanuel; Promeyrat, Xavier; Codas, Ricardo; Fehri, Hakim Fassi; Crouzet, Sebastien; Martin, Xavier

    2015-11-01

    To compare fluoroscopy duration, radiation dose, and efficacy of two ultrasound stone localization systems during extracorporeal shockwave lithotripsy (SWL) treatment. Monocentric prospective data were obtained from patients consecutively treated for renal stones using the Sonolith(®) i-sys (EDAP TMS) lithotripter, with fluoroscopy combined with ultrasound localization using an "outline" Automatic Ultrasound Positioning Support (AUPS) (group A), or the "free-line" Visio-Track (VT) (EDAP-TMS) hand-held three-dimensional ultrasound stone locking system (group B). Efficacy rate was defined as the within-groups proportion stone free or with partial stone fragmentation not needing additional procedures. Statistical analysis used Pearson chi-square tests for categoric variables, nonparametric Mann-Whitney tests for continuous variables, and linear regression for operator learning curve with VT. Continuous variables were reported as median (range) values. Patients in group A (n=73) and group B (n=81) were comparable in baseline characteristics (age, kidney stone size, others) and in SWL application (duration, number of shocks, energy [Joules]). During SWL, the median (range) duration (seconds) of radiation exposure was 159.5 (0-690) in group A and 3.5 (0-478) in group B (P<0.001) and irradiation dose (mGy.cm(2)), 10598 (0-54843) in group A and 163 (0-13926) in group B (P<0.001). Fluoroscopy time significantly decreased with operator experience using VT. The efficacy rate was 54.5% in group A and 79.5% in group B (P=0.001). VT significantly reduced fluoroscopy use during SWL and the duration and dose of patient exposure to ionizing radiation. Stone treatment efficacy was significantly greater with VT mainly because of a better real-time monitoring of the stone.

  4. Different Impacts of Time From Collapse to First Cardiopulmonary Resuscitation on Outcomes After Witnessed Out-of-Hospital Cardiac Arrest in Adults.

    PubMed

    Hara, Masahiko; Hayashi, Kenichi; Hikoso, Shungo; Sakata, Yasushi; Kitamura, Tetsuhisa

    2015-05-01

    It is well known that cardiopulmonary resuscitation (CPR) should be attempted as early as possible after out-of-hospital cardiac arrest (OHCA). However, it is unclear about the impact of time to CPR on OHCA outcome by first documented rhythm (pulseless ventricular tachycardia/ventricular fibrillation [pVT/VF], pulseless electric activity [PEA], and asystole). We enrolled 257,354 adult witnessed OHCA patients between 2007 and 2012 from a prospective nationwide population-based cohort database in Japan. We evaluated relationships between time from collapse to first CPR and neurologically favorable 1-month survival defined as Glasgow-Pittsburg cerebral performance category 1 or 2 by first documented rhythm after witnessed OHCA. We used logistic model for the estimation of prognosis. The number of OHCA patients with pVT/VF, PEA, and asystole were 38,661, 96,906, and 121,787, respectively. The overall neurologically favorable 1-month survival rates were 21.3% in patients with pVT/VF, 2.7% PEA, and 0.6% asystole. The proportion of asystole increased as the time from collapse to CPR delayed, whereas those of pVT/VF and PEA decreased (trend P<0.001). Estimated incidences of end-point after OHCA became lower as first CPR delayed irrespective of type of first documented rhythm, but were different by the rhythm. The average percentage point decreases in neurologically favorable 1-month survival probability for each incremental minute of CPR delay were 8.3%, 4.4%, and 6.4% for patients with pVT/VF, PEA, and asystole, respectively. The OHCA outcome differed by time to first CPR and first documented rhythm. Shortening of time to first CPR is crucial for improving the OHCA outcome. © 2015 American Heart Association, Inc.

  5. Magnetic versus manual catheter navigation for mapping and ablation of right ventricular outflow tract ventricular arrhythmias: a randomized controlled study.

    PubMed

    Zhang, Fengxiang; Yang, Bing; Chen, Hongwu; Ju, Weizhu; Kojodjojo, Pipin; Cao, Kejiang; Chen, Minglong

    2013-08-01

    No randomized controlled study has prospectively compared the performance and clinical outcomes of remote magnetic control (RMC) vs manual catheter control (MCC) during ablation of right ventricular outflow tract (RVOT) ventricular premature complexes (VPC) or ventricular tachycardia (VT). The purpose of this study was to prospectively evaluate the efficacy and safety of using either RMC vs MCC for mapping and ablation of RVOT VPC/VT. Thirty consecutive patients with idiopathic RVOT VPC/VT were referred for catheter ablation and randomized into either the RMC or MCC group. A noncontact mapping system was deployed in the RVOT to identify origins of VPC/VT. Conventional activation and pace-mapping was performed to guide ablation. If ablation performed using 1 mode of catheter control was acutely unsuccessful, the patient crossed over to the other group. The primary endpoints were patients' and physicians' fluoroscopic exposure and times. Mean procedural times were similar between RMC and MCC groups. The fluoroscopic exposure and times for both patients and physicians were much lower in the RMC group than in the MCC group. Ablation was acutely successful in 14 of 15 patients in the MCC group and 10 of 15 in the RMC group. Following crossover, acute success was achieved in all patients. No major complications occurred in either group. During 22 months of follow-up, RVOT VPC recurred in 2 RMC patients. RMC navigation significantly reduces patients' and physicians' fluoroscopic times by 50.5% and 68.6%, respectively, when used in conjunction with a noncontact mapping system to guide ablation of RVOT VPC/VT. Copyright © 2013 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  6. Beyond the Storm: Comparison of Clinical Factors, Arrhythmogenic Substrate, and Catheter Ablation Outcomes in Structural Heart Disease Patients With versus Those Without a History of Ventricular Tachycardia Storm.

    PubMed

    Kumar, Saurabh; Fujii, Akira; Kapur, Sunil; Romero, Jorge; Mehta, Nishaki K; Tanigawa, Shinichi; Epstein, Laurence M; Koplan, Bruce A; Michaud, Gregory F; John, Roy M; Stevenson, William G; Tedrow, Usha B

    2017-01-01

    Catheter ablation can be lifesaving in ventricular tachycardia (VT) storm, but the underlying substrate in patients with storm is not well characterized. We sought to compare the clinical factors, substrate, and outcomes differences in patients with sustained monomorphic VT who present for catheter ablation with VT storm versus those with a nonstorm presentation. Consecutive ischemic (ICM; n = 554) or nonischemic cardiomyopathy patients (NICM; n = 369) with a storm versus nonstorm presentation were studied (ICM storm 186; NICM storm 101). In ICM, storm compared with nonstorm patients had significantly lower left ventricular (LV) ejection fraction (EF), greater number of antiarrhythmic drug (AAD) failures, slower VTs, greater number of scarred LV segments, higher incidence of anterior, septal, and apical endocardial LV scar (all P < 0.05). However, outcomes in follow-up were similar (12-month ventricular arrhythmia [VA]-free survival: 51% vs. 52%, P = 0.6; survival free of death/transplant 75% vs. 87%, P = 0.7). In addition to the above differences, NICM storm patients were also older; however, the extent and distribution of scar was similar except for a higher incidence of lateral endocardial scar in storm patients (P = 0.05). VA-free survival (36% vs. 47%, P = 0.004) and survival free of death/transplant, however, were worse in NICM storm than nonstorm patients (72% vs. 88%, P = 0.001). NICM storm patients had worse VA-free survival than ICM storm patients. There are differences in clinical factors and scar patterns in patients undergoing VT ablation who present with VT storm versus those with a nonstorm presentation. Clinical outcomes are worse in NICM storm patients. © 2016 Wiley Periodicals, Inc.

  7. A short latency vestibular evoked potential (VsEP) produced by bone-conducted acoustic stimulation

    NASA Astrophysics Data System (ADS)

    McAngus Todd, Neil P.; Rosengren, Sally M.; Colebatch, James G.

    2003-12-01

    In this paper data are presented from an experiment which provides evidence for the existence of a short latency, acoustically evoked potential of probable vestibular origin. The experiment was conducted in two phases using bone-conducted acoustic stimulation. In the first phase subjects were stimulated with 6-ms, 500-Hz tone bursts in order to obtain the threshold VT for vestibular evoked myogenic potentials (VEMP). It was confirmed that the difference between bone-conducted auditory and acoustic vestibular thresholds was slightly over 30 dB. The estimated threshold was then used as a reference value in the second part of the experiment to stimulate subjects over a range of intensities from -6 to +18 dB (re:VT). Averaged EEG recordings were made with eight Ag/AgCl electrodes placed on the scalp at Fpz, F3, F4, F7, F8, Cz, T3, and T4 according to the 10-20 system. Below VT auditory midlatency responses (MLRs) were observed. Above VT two additional potentials appeared: a positivity at about 10 ms (P10) which was maximal at Cz, and a negativity at about 15 ms (N15) which was maximal at Fpz. Extrapolation of the growth functions for the P10 and N15 indicated a threshold close to VT, consistent with a vestibular origin of these potentials. Given the low threshold of vestibular acoustic sensitivity it is possible that this mode may make a contribution to the detection of and affective responses to loud low frequency sounds. The evoked potentials may also have application as a noninvasive and nontraumatic test of vestibular projections to the cortex.

  8. Heat and moisture exchangers and heated humidifiers in acute lung injury/acute respiratory distress syndrome patients. Effects on respiratory mechanics and gas exchange.

    PubMed

    Morán, Indalecio; Bellapart, Judith; Vari, Alessandra; Mancebo, Jordi

    2006-04-01

    To compare, in acute lung injury/acute respiratory distress syndrome (ALI/ARDS) patients, the short-term effects of heat and moisture exchangers (HME) and heated humidifiers (HH) on gas exchange, and also on respiratory system mechanics when isocapnic conditions are met. Prospective open clinical study. Intensive Care Service. Seventeen invasively ventilated ALI/ARDS patients. The study was performed in three phases: (1) determinations were made during basal ventilatory settings with HME; (2) basal ventilatory settings were maintained and HME was replaced by an HH; (3) using the same HH, tidal volume (Vt) was decreased until basal PaCO2 levels were reached. FiO2, respiratory rate and PEEP were kept unchanged. Respiratory mechanics, Vdphys, gas exchange and hemodynamic parameters were obtained at each phase. By using HH instead of HME and without changing Vt, PaCO2 decreased from 46+/-9 to 40+/-8 mmHg (p<0.001) and Vdphys decreased from 352+/-63 to 310+/-74 ml (p<0.001). Comparing the first phase with the third, Vt decreased from 521+/-106 to 440+/-118 ml (p<0.001) without significant changes in PaCO2, Vd/Vt decreased from 0.69+/-0.11 to 0.62+/-0.12 (p<0.001), plateau airway pressure decreased from 25+/-6 to 21+/-6 cmH2O (p<0.001) and respiratory system compliance improved from 35+/-12 to 42+/-15 ml/cmH2O (p<0.001). PaO2 remained unchanged in the three phases. Reducing dead space with the use of HH decreases PaCO2 and more importantly, if isocapnic conditions are maintained by reducing Vt, this strategy improves respiratory system compliance and reduces plateau airway pressure.

  9. Prehospital Predictors of Initial Shockable Rhythm in Out-of-Hospital Cardiac Arrest: Findings From the Taichung Sudden Unexpected Death Registry (THUNDER).

    PubMed

    Lin, Yen-Nien; Chang, Shih-Sheng; Wang, Lee-Min; Chi, Hwan-Ting; Ueng, Kwo-Chang; Tsai, Chin-Feng; Phan, Chee-Seong; Lu, Li-Hua; Hii, Choon-Hoon; Chung, Yu-Ting; Chugh, Sumeet S; Chen, Ming-Fong; Wu, Tsu-Juey; Chang, Kuan-Cheng

    2017-03-01

    To identify the incidence and prehospital predictors of ventricular tachycardia/ventricular fibrillation (VT/VF) as the initial arrhythmia in patients with out-of-hospital cardiac arrest (OHCA) in central Taiwan. The Taichung Sudden Unexpected Death Registry program encompasses the Taichung metropolitan area in central Taiwan, with a population of 2.7 million and 17 destination hospitals for patients with OHCA. We performed a detailed analysis of demographic characteristics, circumstances of cardiac arrest, and emergency medical service records using the Utstein Style. From May 1, 2013, through April 30, 2014, resuscitation was attempted in 2013 individuals with OHCA, of which 384 were excluded due to trauma and noncardiac etiologies. Of the 1629 patients with presumed cardiogenic OHCA, 7.9% (n=129) had initial shockable rhythm; this proportion increased to 18.8% (61 of 325) in the witnessed arrest subgroup. Male sex (odds ratio [OR], 2.45; 95% CI, 1.46-4.12; P<.001), age younger than 65 years (OR, 2.39, 95% CI, 1.58-3.62; P<.001), public location of arrest (OR, 4.61; 95% CI, 2.86-7.44; P<.001), and witnessed status (OR, 3.98; 95% CI, 2.62-6.05; P<.001) were independent predictors of VT/VF rhythm. The proportion of patients with OHCA presenting with VT/VF was generally low in this East Asian population. Of the prehospital factors associated with VT/VF, public location of OHCA was the strongest predictor of VT/VF in this population, which may affect planning and deployment of emergency medical services in central Taiwan. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  10. Elevated Monoamine Oxidase-A Distribution Volume in Borderline Personality Disorder Is Associated With Severity Across Mood Symptoms, Suicidality, and Cognition.

    PubMed

    Kolla, Nathan J; Chiuccariello, Lina; Wilson, Alan A; Houle, Sylvain; Links, Paul; Bagby, R Michael; McMain, Shelley; Kellow, Charis; Patel, Jalpa; Rekkas, Paraskevi V; Pasricha, Suvercha; Meyer, Jeffrey H

    2016-01-15

    Monoamine oxidase-A (MAO-A) is a treatment target in neurodegenerative illness and mood disorders that increases oxidative stress and predisposition toward apoptosis. Increased MAO-A levels in prefrontal cortex (PFC) and anterior cingulate cortex (ACC) occur in rodent models of depressive behavior and human studies of depressed moods. Extreme dysphoria is common in borderline personality disorder (BPD), especially when severe, and the molecular underpinnings of severe BPD are largely unknown. We hypothesized that MAO-A levels in PFC and ACC would be highest in severe BPD and would correlate with symptom magnitude. [(11)C] Harmine positron emission tomography measured MAO-A total distribution volume (MAO-A VT), an index of MAO-A density, in severe BPD subjects (n = 14), moderate BPD subjects (n = 14), subjects with a major depressive episode (MDE) only (n = 14), and healthy control subjects (n = 14). All subjects were female. Severe BPD was associated with greater PFC and ACC MAO-A VT compared with moderate BPD, MDE, and healthy control subjects (multivariate analysis of variance group effect: F6,102 = 5.6, p < .001). In BPD, PFC and ACC MAO-A VT were positively correlated with mood symptoms (PFC: r = .52, p = .005; ACC: r = .53, p = .004) and suicidality (PFC: r = .40, p = .037; ACC: r = .38, p = .046), while hippocampus MAO-A VT was negatively correlated with verbal memory (r = -.44, p = .023). These results suggest that elevated MAO-A VT is associated with multiple indicators of BPD severity, including BPD symptomatology, mood symptoms, suicidality, and neurocognitive impairment. Copyright © 2016 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  11. Critical analysis of dual-chamber implantable cardioverter-defibrillator arrhythmia detection : results and technical considerations.

    PubMed

    Wilkoff, B L; Kühlkamp, V; Volosin, K; Ellenbogen, K; Waldecker, B; Kacet, S; Gillberg, J M; DeSouza, C M

    2001-01-23

    One of the perceived benefits of dual-chamber implantable cardioverter-defibrillators (ICDs) is the reduction in inappropriate therapy due to new detection algorithms. It was the purpose of the present investigation to propose methods to minimize bias during such comparisons and to report the arrhythmia detection clinical results of the PR Logic dual-chamber detection algorithm in the GEM DR ICD in the context of these methods. Between November 1997 and October 1998, 933 patients received the GEM DR ICD in this prospective multicenter study. A total of 4856 sustained arrhythmia episodes (n=311) with stored electrogram and marker channel were classified by the investigators; 3488 episodes (n=232) were ventricular tachycardia (VT)/ventricular fibrillation (VF), and 1368 episodes (n=149) were supraventricular tachycardia (SVT). The overall detection results were corrected for multiple episodes within a patient with the generalized estimating equations (GEE) method with an exchangeable correlation structure between episodes. The relative sensitivity for detection of sustained VT and/or VF was 100.0% (3488 of 3488, n=232; 95% CI 98.3% to 100%), the VT/VF positive predictivity was 88.4% uncorrected (3488 of 3945, n=278) and 78.1% corrected (95% CI 73.3% to 82.3%) with the GEE method, and the SVT positive predictivity was 100.0% (911 of 911, n=101; 95% CI 96% to 100%). A structured approach to analysis limits the bias inherent in the evaluation of tachycardia discrimination algorithms through the use of relative VT/VF sensitivity, VT/VF positive predictivity, and SVT positive predictivity along with corrections for multiple tachycardia episodes in a single patient.

  12. The electrolytic inferior vena cava model (EIM) to study thrombogenesis and thrombus resolution with continuous blood flow in the mouse

    PubMed Central

    Diaz, Jose A.; Alvarado, Christine M.; Wrobleski, Shirley K.; Slack, Dallas W.; Hawley, Angela E.; Farris, Diana M.; Henke, Peter K.; Wakefield, Thomas W.; Myers, Daniel D.

    2016-01-01

    Summary Previously, we presented the electrolytic inferior vena cava (IVC) model (EIM) during acute venous thrombosis (VT). Here, we present our evaluation of the EIM for chronic VT time points in order to determine whether this model allows for the study of thrombus resolution. C57BU6 mice (n=191) were utilised. In this model a copper-wire, inserted into a 25-gauge needle, is placed in the distal IVC and another subcutaneously. An electrical current (250 µAmp/15 minutes) activates the endothelial cells, inducing thrombogenesis. Ultrasound, thrombus weight (TW), vein wall leukocyte counts, vein wall thickness/fibrosis scoring, thrombus area and soluble P-selectin (sP-sel) were performed at baseline, days 1, 2, 4, 6, 9, 11 and 14, post EIM. A correlation between TW and sP-sel was also determined. A thrombus formed in each mouse undergoing EIM. Blood flow was documented by ultrasound at all time points. IVC thrombus size increased up to day 2 and then decreased over time, as shown by ultrasound, TW, and sP-sel levels. TW and sP-sel showed a strong positive correlation (r=0.48, p<0.0002). Vein wall neutrophils were the most common cell type present in acute VT (up to day 2) with monocytes becoming the most prevalent in chronic VT (from day 6 to day 14). Thrombus resolution was demonstrated by ultrasound, TW and thrombus area. In conclusion, the EIM produces a non-occlusive and consistent IVC thrombus, in the presence of constant blood flow, allowing for the study of VT at both acute and chronic time points. Thrombus resolution was demonstrated by all modalities utilised in this study. PMID:23571406

  13. LV mechanical dispersion as a predictor of ventricular arrhythmia in patients with advanced systolic heart failure : A pilot study.

    PubMed

    Banasik, G; Segiet, O; Elwart, M; Szulik, M; Lenarczyk, R; Kalarus, Z; Kukulski, T

    2016-11-01

    Myocardial mechanical dyssynchrony induced by the presence of postinfarction scar and/or conduction abnormalities in patients with a left ventricular ejection fraction (LVEF) of < 35 % may be associated with a greater propensity toward inducing serious ventricular arrhythmia [(ventricular tachycardia (VT), ventricular fibrillation (VF)] and sudden cardiac death. The assessment of regional myocardial function using tissue Doppler echocardiography (TDE) allows for noninvasive analysis of regional mechanical dysfunction (LV mechanical dispersion). The aim of this study was to evaluate the TDE-based mechanical dispersion as a potential echocardiographic predictor of VT/VF. The study group consisted of 47 consecutive ambulatory patients with implanted cardiac resynchronization therapy-defibrillator (CRT-D) devices who were divided into two groups: Group 1 (n = 29) comprised patients with recorded episodes of VT/VF, in whom baseline TDE data were available, and group 2 (n = 18) comprised patients without registered VT/VF in the device memory within 4 years after implantation. LV mechanical dispersion was defined as the standard deviation of the time measured from the beginning of the QRS complex to the peak longitudinal strain in apical four-chamber and two-chamber views. A retrospective quantitative assessment of LV regional deformation was based on the color tissue velocity recordings. The average time to event after implantation was 345 days. Patients with electrical events demonstrated greater mechanical dispersion: 99.14 ± 33.60 vs. 72.98 ± 19.70, p=0.002. During the 4-year follow-up, patients with documented VT/VF were characterized by significantly higher LV mechanical dispersion as compared with patients without electrical events. Measurement of LV mechanical dispersion might be helpful in determining the risk of sudden cardiac death.

  14. Grating coupled SPR microarray analysis of proteins and cells in blood from mice with breast cancer.

    PubMed

    Mendoza, A; Torrisi, D M; Sell, S; Cady, N C; Lawrence, D A

    2016-01-21

    Biomarker discovery for early disease diagnosis is highly important. Of late, much effort has been made to analyze complex biological fluids in an effort to develop new markers specific for different cancer types. Recent advancements in label-free technologies such as surface plasmon resonance (SPR)-based biosensors have shown promise as a diagnostic tool since there is no need for labeling or separation of cells. Furthermore, SPR can provide rapid, real-time detection of antigens from biological samples since SPR is highly sensitive to changes in surface-associated molecular and cellular interactions. Herein, we report a lab-on-a-chip microarray biosensor that utilizes grating-coupled surface plasmon resonance (GCSPR) and grating-coupled surface plasmon coupled fluorescence (GCSPCF) imaging to detect circulating tumor cells (CTCs) from a mouse model (FVB-MMTV-PyVT). GCSPR and GCSPCF analysis was accomplished by spotting antibodies to surface cell markers, cytokines and stress proteins on a nanofabricated GCSPR microchip and screening blood samples from FVB control mice or FVB-MMTV-PyVT mice with developing mammary carcinomas. A transgenic MMTV-PyVT mouse derived cancer cell line was also analyzed. The analyses indicated that CD24, CD44, CD326, CD133 and CD49b were expressed in both cell lines and in blood from MMTV-PyVT mice. Furthermore, cytokines such as IL-6, IL-10 and TNF-α, along with heat shock proteins HSP60, HSP27, HSc70(HSP73), HSP90 total, HSP70/HSc70, HSP90, HSP70, HSP90 alpha, phosphotyrosine and HSF-1 were overexpressed in MMTV-PyVT mice.

  15. In Vivo Measurement of GABA Transmission in Healthy Subjects and Schizophrenia Patients

    PubMed Central

    Frankle, W. Gordon; Cho, Raymond Y.; Prasad, Konasale M.; Mason, N. Scott; Paris, Jennifer; Himes, Michael L.; Walker, Christopher; Lewis, David A.; Narendran, Rajesh

    2016-01-01

    Objective Postmortem studies in schizophrenia reveal alterations in gene products that regulate the release and extracellular persistence of GABA. However, results of in vivo studies of schizophrenia measuring total tissue GABA with magnetic resonance spectroscopy (MRS) have been inconsistent. Neither the postmortem nor the MRS studies directly address the physiological properties of GABA neurotransmission. The present study addresses this question through an innovative positron emission tomography (PET) paradigm. Method The binding of [11C]flumazenil, a benzodiazepine-specific PET radiotracer, was measured before and after administration of tiagabine (0.2 mg/kg of body weight), a GABA membrane transporter (GAT1) blocker, in 17 off-medication patients with schizophrenia and 22 healthy comparison subjects. Increased extracellular GABA, through GAT1 blockade, enhances the affinity of GABAA receptors for benzodiazepine ligands, detected as an increase in [11C]flumazenil tissue distribution volume (VT). Results [11C]Flumazenil VT was significantly increased across all cortical brain regions in the healthy comparison group but not in the schizophrenia group. This lack of effect was most prominent in the antipsychotic-naive schizophrenia group. In this subgroup, [11C]flumazenil ΔVT in the medial temporal lobe was correlated with positive symptoms, and baseline [11C] flumazenil VT in the medial temporal lobe was negatively correlated with visual learning. In the healthy comparison group but not the schizophrenia group, [11C]flumazenil ΔVT was positively associated with gamma-band oscillation power. Conclusions This study demonstrates, for the first time, an in vivo impairment in GABA transmission in schizophrenia, most prominent in antipsychotic-naive individuals. The impairment in GABA transmission appears to be linked to clinical symptoms, disturbances in cortical oscillations, and cognition. PMID:26133962

  16. In vivo measurement of GABA transmission in healthy subjects and schizophrenia patients.

    PubMed

    Frankle, W Gordon; Cho, Raymond Y; Prasad, Konasale M; Mason, N Scott; Paris, Jennifer; Himes, Michael L; Walker, Christopher; Lewis, David A; Narendran, Rajesh

    2015-11-01

    Postmortem studies in schizophrenia reveal alterations in gene products that regulate the release and extracellular persistence of GABA. However, results of in vivo studies of schizophrenia measuring total tissue GABA with magnetic resonance spectroscopy (MRS) have been inconsistent. Neither the postmortem nor the MRS studies directly address the physiological properties of GABA neurotransmission. The present study addresses this question through an innovative positron emission tomography (PET) paradigm. The binding of [(11)C]flumazenil, a benzodiazepine-specific PET radiotracer, was measured before and after administration of tiagabine (0.2 mg/kg of body weight), a GABA membrane transporter (GAT1) blocker, in 17 off-medication patients with schizophrenia and 22 healthy comparison subjects. Increased extracellular GABA, through GAT1 blockade, enhances the affinity of GABAA receptors for benzodiazepine ligands, detected as an increase in [(11)C]flumazenil tissue distribution volume (VT). [(11)C]Flumazenil VT was significantly increased across all cortical brain regions in the healthy comparison group but not in the schizophrenia group. This lack of effect was most prominent in the antipsychotic-naive schizophrenia group. In this subgroup, [(11)C]flumazenil ΔVT in the medial temporal lobe was correlated with positive symptoms, and baseline [(11)C]flumazenil VT in the medial temporal lobe was negatively correlated with visual learning. In the healthy comparison group but not the schizophrenia group, [(11)C]flumazenil ΔVT was positively associated with gamma-band oscillation power. This study demonstrates, for the first time, an in vivo impairment in GABA transmission in schizophrenia, most prominent in antipsychotic-naive individuals. The impairment in GABA transmission appears to be linked to clinical symptoms, disturbances in cortical oscillations, and cognition.

  17. Increased ventilatory variability and complexity in patients with hyperventilation disorder.

    PubMed

    Bokov, Plamen; Fiamma, Marie-Noëlle; Chevalier-Bidaud, Brigitte; Chenivesse, Cécile; Straus, Christian; Similowski, Thomas; Delclaux, Christophe

    2016-05-15

    It has been hypothesized that hyperventilation disorders could be characterized by an abnormal ventilatory control leading to enhanced variability of resting ventilation. The variability of tidal volume (VT) often depicts a nonnormal distribution that can be described by the negative slope characterizing augmented breaths formed by the relationship between the probability density distribution of VT and VT on a log-log scale. The objectives of this study were to describe the variability of resting ventilation [coefficient of variation (CV) of VT and slope], the stability in respiratory control (loop, controller and plant gains characterizing ventilatory-chemoresponsiveness interactions) and the chaotic-like dynamics (embedding dimension, Kappa values characterizing complexity) of resting ventilation in patients with a well-defined dysfunctional breathing pattern characterized by air hunger and constantly decreased PaCO2 during a cardiopulmonary exercise test. Compared with 14 healthy subjects with similar anthropometrics, 23 patients with hyperventilation were characterized by increased variability of resting tidal ventilation (CV of VT median [interquartile]: 26% [19-35] vs. 36% [28-48], P = 0.020; slope: -6.63 [-7.65; -5.36] vs. -3.88 [-5.91; -2.66], P = 0.004) that was not related to increased chemical drive (loop gain: 0.051 [0.039-0.221] vs. 0.044 [0.012-0.087], P = 0.149) but that was related to an increased ventilatory complexity (Kappa values, P < 0.05). Plant gain was decreased in patients and correlated with complexity (with Kappa 5 - degree 5: Rho = -0.48, P = 0.006). In conclusion, well-defined patients suffering from hyperventilation disorder are characterized by increased variability of their resting ventilation due to increased ventilatory complexity with stable ventilatory-chemoresponsiveness interactions. Copyright © 2016 the American Physiological Society.

  18. Benchmarking the ERG valve tip and MRI Interventions Smart Flow neurocatheter convection-enhanced delivery system's performance in a gel model of the brain: employing infusion protocols proposed for gene therapy for Parkinson's disease

    NASA Astrophysics Data System (ADS)

    Sillay, Karl; Schomberg, Dominic; Hinchman, Angelica; Kumbier, Lauren; Ross, Chris; Kubota, Ken; Brodsky, Ethan; Miranpuri, Gurwattan

    2012-04-01

    Convection-enhanced delivery (CED) is an advanced infusion technique used to deliver therapeutic agents into the brain. CED has shown promise in recent clinical trials. Independent verification of published parameters is warranted with benchmark testing of published parameters in applicable models such as gel phantoms, ex vivo tissue and in vivo non-human animal models to effectively inform planned and future clinical therapies. In the current study, specific performance characteristics of two CED infusion catheter systems, such as backflow, infusion cloud morphology, volume of distribution (mm3) versus the infused volume (mm3) (Vd/Vi) ratios, rate of infusion (µl min-1) and pressure (mmHg), were examined to ensure published performance standards for the ERG valve-tip (VT) catheter. We tested the hypothesis that the ERG VT catheter with an infusion protocol of a steady 1 µl min-1 functionality is comparable to the newly FDA approved MRI Interventions Smart Flow (SF) catheter with the UCSF infusion protocol in an agarose gel model. In the gel phantom models, no significant difference was found in performance parameters between the VT and SF catheter. We report, for the first time, such benchmark characteristics in CED between these two otherwise similar single-end port VT with stylet and end-port non-stylet infusion systems. Results of the current study in agarose gel models suggest that the performance of the VT catheter is comparable to the SF catheter and warrants further investigation as a tool in the armamentarium of CED techniques for eventual clinical use and application.

  19. Virtual tissues in toxicology.

    PubMed

    Shah, Imran; Wambaugh, John

    2010-02-01

    New approaches are vital for efficiently evaluating human health risk of thousands of chemicals in commerce. In vitro models offer a high-throughput approach for assaying chemical-induced molecular and cellular changes; however, bridging these perturbations to in vivo effects across chemicals, dose, time, and species remains challenging. Technological advances in multiresolution imaging and multiscale simulation are making it feasible to reconstruct tissues in silico. In toxicology, these "virtual" tissues (VT) aim to predict histopathological outcomes from alterations of cellular phenotypes that are controlled by chemical-induced perturbations in molecular pathways. The behaviors of thousands of heterogeneous cells in tissues are simulated discretely using agent-based modeling (ABM), in which computational "agents" mimic cell interactions and cellular responses to the microenvironment. The behavior of agents is constrained by physical laws and biological rules derived from experimental evidence. VT extend compartmental physiologic models to simulate both acute insults as well as the chronic effects of low-dose exposure. Furthermore, agent behavior can encode the logic of signaling and genetic regulatory networks to evaluate the role of different pathways in chemical-induced injury. To extrapolate toxicity across species, chemicals, and doses, VT require four main components: (a) organization of prior knowledge on physiologic events to define the mechanistic rules for agent behavior, (b) knowledge on key chemical-induced molecular effects, including activation of stress sensors and changes in molecular pathways that alter the cellular phenotype, (c) multiresolution quantitative and qualitative analysis of histologic data to characterize and measure chemical-, dose-, and time-dependent physiologic events, and (d) multiscale, spatiotemporal simulation frameworks to effectively calibrate and evaluate VT using experimental data. This investigation presents the motivation, implementation, and application of VT with examples from hepatotoxicity and carcinogenesis.

  20. Effects of adrenaline on rhythm transitions in out-of-hospital cardiac arrest.

    PubMed

    Neset, Andres; Nordseth, Trond; Kramer-Johansen, Jo; Wik, Lars; Olasveengen, Theresa M

    2013-11-01

    We wanted to study the effects of intravenous (i.v.) adrenaline (epinephrine) on rhythm transitions during cardiac arrest with initial or secondary ventricular fibrillation/tachycardia (VF/VT). Post hoc analysis of patients included in a randomised controlled trial of i.v. drugs in adult, non-traumatic out-of-hospital cardiac arrest patients who were defibrillated and had a readable electrocardiography recording. Patients who received adrenaline were compared with patients who did not. Cardiac rhythms were annotated manually using the defibrillator data. Eight hundred and forty-nine patients were included in the randomised trial of which 223 were included in this analysis; 119 in the adrenaline group and 104 in the no-adrenaline group. The proportion of patients with one or more VF/VT episodes after temporary return of spontaneous circulation (ROSC) was higher in the adrenaline than in the no-adrenaline group, 24% vs. 12%, P = 0.03. Most relapses from ROSC to VF/VT in the no-adrenaline group occurred during the first 20 min of resuscitation, whereas patients in the adrenaline group experienced such relapses even after 20 min. Fibrillations from asystole or pulseless electrical activity, shock resistant VF/VT and the number of rhythm transitions per patient was higher in the adrenalin group compared with the no-adrenalin group: 90% vs. 69%, P < 0.001; 46% vs. 33%, P = 0.006; median 8 (5,13) vs. 2 (1,5), P < 0.001, respectively. Patients who received adrenaline had more rhythm transitions from ROSC and non-shockable rhythms to VF/VT. © 2013 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

Top