Sample records for wachstumsregulation von legionella

  1. Characteristics of environmental isolates of Legionella pneumophila. [Legionella

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Orrison, L.H.; Cherry, W.B.; Fliermans, C.B.

    1981-07-01

    Thirty-eight cultures of Legionella pneumophila isolated from survace waters were characterized by their morphological, tinctorial, biochemical, and serological properties and by their ability to produce disease in guinea pigs. Their susceptibility to antimicrobial agents also was tested. When they were compared with clinical isolates, no important differences were found between cultures from the two sources. Sodium hippurate hydrolysis, gelatin liquefaction, pigment formation, and ..beta..-lactamase and alkaline phosphatase activity were useful in differentiating the four described species of Legionella. Hydrolysis of diacetylfluorescein and the inability to reduce nitrate help to distinguish Legionella species from other gram-negative bacterial rods.

  2. Comparison of Sofia Legionella FIA and BinaxNOW® Legionella urinary antigen card in two national reference centers.

    PubMed

    Beraud, L; Gervasoni, K; Freydiere, A M; Descours, G; Ranc, A G; Vandenesch, F; Lina, G; Gaia, V; Jarraud, S

    2015-09-01

    The Sofia Legionella Fluorescence Immunoassay (FIA; Quidel) is a recently introduced rapid immunochromatographic diagnostic test for Legionnaires' disease using immunofluorescence technology designed to enhance its sensitivity. The aim of this study was to evaluate its performance for the detection of urinary antigens for Legionella pneumophila serogroup 1 in two National Reference Centers for Legionella. The sensitivity and specificity of the Sofia Legionella FIA test were determined in concentrated and nonconcentrated urine samples, before and after boiling, in comparison with the BinaxNOW® Legionella Urinary Antigen Card (UAC; Alere). Compared with BinaxNOW® Legionella UAC, the sensitivity of the Sofia Legionella test was slightly higher in nonconcentrated urine samples and was identical in concentrated urine samples. The specificity of the Sofia Legionella FIA test was highly reduced by the concentration of urine samples. In nonconcentrated samples, a lack of specificity was observed in 2.3 % of samples, all of them resolved by heat treatment. The Sofia Legionella FIA is a sensitive test for detecting Legionella urinary antigens with no previous urine concentration. However, all positive samples have to be re-tested after boiling to reach a high specificity. The reading is automatized on the Sofia analyzer, which can be connected to laboratory information systems, facilitating accurate and rapid reporting of results.

  3. Legionella sainthelensi: a new species of Legionella isolated from water near Mt. St. Helens.

    PubMed Central

    Campbell, J; Bibb, W F; Lambert, M A; Eng, S; Steigerwalt, A G; Allard, J; Moss, C W; Brenner, D J

    1984-01-01

    Six strains of a new species, Legionella sainthelensi, were isolated from freshwater in areas affected by the volcanic eruptions of Mt. St. Helens in the state of Washington. Strains of L. sainthelensi are culturally and biochemically similar to other legionellae. They grow on buffered charcoal yeast agar but not on media that lack cysteine. They are gram-negative, nonsporeforming, motile rods that are positive in reactions for catalase, oxidase, gelatin liquefaction, and beta-lactamase. They are negative in reactions for urease, hydrolysis of hippurate, reduction of nitrates, fermentation of glucose, and blue-white autofluorescence. Their cell wall fatty acid composition is qualitatively similar to those of other legionellae, with 50 to 62% branched-chain fatty acids. They contain the isobranched-chain 14- and 16-carbon acids and anteisobranched-chain 15- and 17-carbon acids and relatively large amounts of straight-chain 16-carbon acid. All strains of L. sainthelensi contain approximately equal amounts of ubiquinones Q9, Q10, Q11, and Q12, a pattern similar to those of Legionella bozemanii, Legionella dumoffi, and Legionella longbeachae. Serological cross-reactions were observed between L. sainthelensi, both serogroups of L. longbeachae, and Legionella oakridgensis. Three strains of L. sainthelensi were greater than 90% related by DNA hybridization. The type strain of L. sainthelensi, Mt. St. Helens 4, was 36% related to the type strain of L. longbeachae and 3 to 14% related to the other nine described Legionella species. PMID:6712210

  4. Treatment strategies for Legionella infection.

    PubMed

    Pedro-Botet, M Luisa; Yu, Victor L

    2009-05-01

    Given the nonspecific clinical manifestations of Legionnaires' disease and the high mortality of untreated Legionnaires' disease, we recommend routine use of Legionella testing, especially the Legionella urinary antigen test, for all patients with community-acquired pneumonia. This includes patients with ambulatory pneumonia and hospitalized children. Legionella cultures should be more widely available, especially in hospitals where the drinking water is colonized with Legionella. Azithromycin or levofloxacin can be considered as first-line therapy. Other antibiotics including tetracyclines, tigecycline, other fluoroquinolones and other macrolides (especially clarithromycin) are also effective. The clinical response of quinolones may be somewhat more favorable compared to macrolides, but the outcome is similar. If the Legionnaires' disease is hospital-acquired, culturing of the hospital drinking water for Legionella is indicated.

  5. Technologies for Legionella Control

    EPA Science Inventory

    Presentation includes a review of new Office of Water document entitled "Technologies for Legionella Control in Premise Plumbing Systems", and discussion on ORD research projects involving Legionella and disinfection.

  6. Susceptibility of Pittsburgh pneumonia agent (Legionella micdadei) and other newly recognized members of the genus Legionella to nineteen antimicrobial agents.

    PubMed Central

    Pasculle, A W; Dowling, J N; Weyant, R S; Sniffen, J M; Cordes, L G; Gorman, G M; Feeley, J C

    1981-01-01

    The susceptibilities of 11 strains representing the five recognized species of Legionella were determined by agar dilution testing on buffered charcoal-yeast extract agar. All of the legionellae tested were susceptible to rifampin, erythromycin, rosaramycin, chloramphenicol, and the aminoglycosides and were resistant to clindamycin and vancomycin. Susceptibilities to penicillins and cephalosporins were variable. Legionella micdadei, Legionella bozemanii, and Legionella gormanii were susceptible to these agents, but minimal inhibitory concentrations for each species were different. Legionella dumoffii resembled Legionella pneumophila in being resistant to penicillin, cephalothin, and cephamandole and susceptible to moxalactam and cefoxitin. All species except L. micdadei produced beta-lactamase. PMID:7325645

  7. Plasmid Detection in Legionella pneumophila and Legionella-like Organisms.

    DTIC Science & Technology

    1980-04-30

    in view of the narrow spectrum of antibiotics effective in the treatment of legionellosis and Legionella-like diseases , the acquisition of drug...pneumonia. Ann. Intern. Med. 91:831-834. 15. McDade, J. E., D. J. Brenner, and F. M. Bozeman. 1979. Legionnaires ’ disease bacterium isolated in 1947...AD-ASM 700 ARMY MEDICAL RESEARCH INST OF INFECTIOUS DISEASES FR--ETC F/6 6/5 PLASNIC DETECTION IN LEGIONELLA PNEUNOPHILA ND LESIONELLA-LIKE--ETe(U

  8. Legionella anisa: a new species of Legionella isolated from potable waters and a cooling tower

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gorman, G.W.; Feeley, J.C.; Steigerwalt, A.

    1985-02-01

    Between March 1980 and June 1981, five strains of Legionella-like organisms were isolated from water. Four were recovered from potable water collected from hospitals in Chicago, IL, and Los Angeles, CA, during outbreaks of nosocomial legionellosis. The fifth strain was isolated from water collected from an industrial cooling tower in Jamestown, NY. The strains exhibited biochemical reactions typical of Legionella species and were gram-negative motile rods which grew on buffered charcoal-yeast extract agar but not on blood agar, required cysteine, and were catalase positive, urease negative, nitrate negative, hippurate negative, and nonfermentative. All strains were positive for oxidase and beta-lactamasemore » and produced a brown, diffusible pigment. The fatty-acid composition and ubiquinone content of these strains were consistent with those of other Legionella species. Direct fluorescent-antibody examination of the five strains with conjugates to previously described Legionella species demonstrated no cross-reactions except with the conjugates to L. longbeachae serogroup 2 and L. bozemannii serogroup 2. Four strains gave a 4+ reaction to the L. longbeachae serogroup 2 conjugate and the fifth strain gave a 1+ reaction. Each of the five strains gave a 4+ reaction with the conjugate to L. bozemanii serogroup 2. DNAs from the five strains were highly related (84 to 99%) and showed 5 to 57% relatedness to other Legionella species. These strains constitute a new species in the genus Legionella, and the name Legionella anisa sp. nov. is proposed.« less

  9. Plasmid Isolation in Legionella pneumophila and Legionella-like Organisms.

    DTIC Science & Technology

    1980-08-22

    hag, to our knowledge, not been reported. However in view of the narrow spectrum of antibiotics effective in the treatment of diseases caused by L...8217 disease bacterium isolated in 1947. Ann. Intern. Med. 90:659-661. 16. Meyers, J. A., D. Sanchez, L. P. Elwell, and S . Falkow. 1976. Simple agarose gel...AD-A090 844 ARMY MEDICAL RESEARCH INST OF INFECTIOUS DISEASES FR-ETC FIG 6/5 PLASMID ISOLATI ON IN LEGIONELLA PNEUMOPHILA AND LEGIONELLA-LIKE--ETC(U

  10. Legionella and non-Legionella bacteria in a biological treatment plant.

    PubMed

    Fykse, Else Marie; Aarskaug, Tone; Thrane, Ingjerd; Blatny, Janet Martha

    2013-02-01

    Legionella pneumophila were previously identified in the aeration ponds (up to 10(10) CFU/L) of a biological wastewater treatment plant at Borregaard Ind. Ltd., Sarpsborg, Norway, and in air samples (up to 3300 CFU/m(3)) collected above the aeration ponds. After 3 outbreaks of Legionnaires' disease reported in this area in 2005 and 2008, the aeration ponds of the plant were shut down by the Norwegian authorities in September 2008. The aim of the present work was to analyze the Legionella and non-Legionella bacterial communities in the aeration ponds before and during the shutdown process and to identify potential human pathogens. The non-Legionella bacterial community was investigated in selected samples during the shutdown process by 16S rDNA sequencing of clone libraries (400 clones) and growth analysis. The concentration of L. pneumophila and Pseudomonas spp. DNA were monitored by quantitative PCR. Results showed a decrease in the concentration of L. pneumophila and Pseudomonas spp. during the shutdown. This was accompanied by a significant change in the composition of the bacterial community in the aeration ponds. This study demonstrated that several advanced analytical methods are necessary to characterize the bacterial population in complex environments, such as the industrial aeration ponds.

  11. Legionella: virulence factors and host response.

    PubMed

    Misch, Elizabeth Ann

    2016-06-01

    Legionella pneumophila is a facultative intracellular pathogen and an important cause of community-acquired and nosocomial pneumonia. This review focuses on the latest literature examining Legionella's virulence strategies and the mammalian host response. Recent studies identify novel virulence strategies used by L. pneumophila and new aspects of the host immune response to this pathogen. Legionella prevents acidification of the phagosome by recruiting Rab1, a host protein. Legionella also blocks a conserved endoplasmic reticulum stress response. To access iron from host stores, L. pneumophila upregulates more regions allowing vacuolar colocalization N. In response to Legionella, the host cell may activate caspase-1, caspase-11 (mice) or caspase-4 (humans). Caspase-3 and apoptosis are activated by a secreted, bacterial effector. Infected cells send signals to their uninfected neighbors, allowing the elaboration of inflammatory cytokines in trans. Antibody subclasses provide robust protection against Legionella. L. pneumophila is a significant human pathogen that lives in amoebae in the environment but may opportunistically infect the alveolar macrophage. To maintain its intracellular lifestyle, Legionella extracts essential iron from the cell, blocks inflammatory responses and manipulates trafficking to avoid fusion with the lysosome. The mammalian host has counter strategies, which include the release of proinflammatory cytokines, the activation of caspases and antibody-mediated immunity.

  12. Occurrence of Legionella in UK household showers.

    PubMed

    Collins, Samuel; Stevenson, David; Bennett, Allan; Walker, Jimmy

    2017-04-01

    Household water systems have been proposed as a source of sporadic, community acquired Legionnaires' disease. Showers represent a frequently used aerosol generating device in the domestic setting yet little is known about the occurrence of Legionella spp. in these systems. This study has investigated the prevalence of Legionella spp. by culture and qPCR in UK household showers. Ninety nine showers from 82 separate properties in the South of England were sampled. Clinically relevant Legionella spp. were isolated by culture in 8% of shower water samples representing 6% of households. Legionella pneumophila sg1 ST59 was isolated from two showers in one property and air sampling demonstrated its presence in the aerosol state. A further 31% of showers were positive by Legionella spp. qPCR. By multi-variable binomial regression modelling Legionella spp. qPCR positivity was associated with the age of the property (p=0.02), the age of the shower (p=0.01) and the frequency of use (p=0.09). The concentration of Legionella spp. detected by qPCR was shown to decrease with increased frequency of use (p=0.04) and more frequent showerhead cleaning (p=0.05). There was no association between Legionella spp. qPCR positivity and the cold water supply or the showerhead material (p=0.65 and p=0.71, respectively). Household showers may be important reservoirs of clinically significant Legionella and should be considered in source investigations. Simple public health advice may help to mitigate the risk of Legionella exposure in the domestic shower environment. Crown Copyright © 2016. Published by Elsevier GmbH. All rights reserved.

  13. A new Legionella species, Legionella feeleii species nova, causes Pontiac fever in an automobile plant.

    PubMed

    Herwaldt, L A; Gorman, G W; McGrath, T; Toma, S; Brake, B; Hightower, A W; Jones, J; Reingold, A L; Boxer, P A; Tang, P W

    1984-03-01

    From 15 to 21 August 1981, Pontiac fever affected 317 automobile assembly plant workers. Results of serologic tests were negative for Mycoplasma, Chlamydia, respiratory tract viruses, and previously described legionellae. A gram-negative, rod-shaped organism (WO-44C) that did not grow on blood agar, required L-cysteine for growth, and contained large amounts of branched-chain fatty acids was isolated from a water-based coolant. The organism did not react with antisera against other legionellae, and on DNA hybridization the organism was less than 10% related to other Legionella species. Geometric mean titers found by indirect fluorescent antibody testing to WO-44C were significantly higher in ill employees than in controls (p = 0.0001). Attack rates by department decreased linearly with the department's distance from the implicated coolant system. The etiologic agent apparently was a new Legionella species; we propose the name Legionella feeleii species nova (AATC 35072). This is the first outbreak of nonpneumonic legionellosis in which the etiologic agent is not L. pneumophila, serogroup 1.

  14. [Legionella pneumonia after the use of CPAP equipment].

    PubMed

    Stolk, Jaap M; Russcher, Anne; van Elzakker, Erika P M; Schippers, Emile F

    2016-01-01

    Continuous positive airway pressure (CPAP) equipment can be colonised by Legionellae and might cause Legionella pneumonia in the user. However, there is no reported case of Legionella pneumonia related to CPAP equipment in which an identical Legionella was found in both the patient and the CPAP equipment. A 51-year-old man came to the Emergency Department with fever, confusion and dyspnoea that had been present for 3 days. His medical history included obstructive sleep apnoea, for which he had been using CPAP therapy at home for 10 weeks. The CPAP equipment showed signs of poor maintenance. Chest X-ray revealed a pulmonary consolidation. Laboratory investigation resulted in a positive urine antigen test for Legionella. Water from the CPAP equipment and sputum from the patient revealed Legionella pneumophila. Serotyping and sequence-based typing showed an identical L. pneumophila serotype 1 ST37. It is important to be aware that CPAP equipment can be colonised with Legionellae and might cause Legionella pneumonia. It is therefore necessary to ask about CPAP therapy in a patient with community-acquired pneumonia.

  15. Survey of Legionella spp. in Mud Spring Recreation Area

    NASA Astrophysics Data System (ADS)

    Hsu, B.-M.; Ma, P.-H.; Su, I.-Z.; Chen, N.-S.

    2009-04-01

    Legionella genera are parasites of FLA, and intracellular bacterial replication within the FLA plays a major role in the transmission of disease. At least 13 FLA species—including Acanthamoeba spp., Naegleria spp., and Hartmannella spp.—support intracellular bacterial replication. In the study, Legionellae were detected with microbial culture or by direct DNA extraction and analysis from concentrated water samples or cultured free-living amoebae, combined with molecular methods that allow the taxonomic identification of these pathogens. The water samples were taken from a mud spring recreation area located in a mud-rock-formation area in southern Taiwan. Legionella were detected in 15 of the 34 samples (44.1%). Four of the 34 samples analyzed by Legionella culture were positive for Legionella, five of 34 were positive for Legionella when analyzed by direct DNA extraction and analysis, and 11 of 34 were positive for amoebae-resistant Legionella when analyzed by FLA culture. Ten samples were shown to be positive for Legionella by one analysis method and five samples were shown to be positive by two analysis methods. However, Legionella was detected in no sample by all three analysis methods. This suggests that the three analysis methods should be used together to detect Legionella in aquatic environments. In this study, L. pneumophila serotype 6 coexisted with A. polyphaga, and two uncultured Legionella spp. coexisted with either H. vermiformis or N. australiensis. Of the unnamed Legionella genotypes detected in six FLA culture samples, three were closely related to L. waltersii and the other three were closely related to L. pneumophila serotype 6. Legionella pneumophila serotype 6, L. drancourtii, and L. waltersii are noted endosymbionts of FLA and are categorized as pathogenic bacteria. This is significant for human health because these Legionella exist within FLA and thus come into contact with typically immunocompromised people.

  16. Development of an improved PCR-ICT hybrid assay for direct detection of Legionellae and Legionella pneumophila from cooling tower water specimens.

    PubMed

    Horng, Yu-Tze; Soo, Po-Chi; Shen, Bin-Jon; Hung, Yu-Li; Lo, Kai-Yin; Su, Hsun-Pi; Wei, Jun-Rong; Hsieh, Shang-Chen; Hsueh, Po-Ren; Lai, Hsin-Chih

    2006-06-01

    A novelly improved polymerase chian reaction and immunochromatography test (PCR-ICT) hybrid assay comprising traditional multiplex-nested PCR and ICT, (a lateral-flow device) was developed for direct detection of Legionella bacteria from environmental cooling tower samples. The partial 16S rDNA (specific for Legionella spp.) and dnaJ (specific for Legionella pneumophila) genes from Legionella chromosome were first specifically amplified by multiplex-nested PCR, respectively, followed by detection using ICT strip. Reading of results was based on presence or absence of the two test lines on the strips. Presence of test line 1 indicated existence of Legionella spp. specific 16S rDNA and identified Legionella spp. Presence of test line 2 further indicated existence of dnaJ and thus specifically identified L. pneumophila. In contrast, for non-Legionellae bacteria no test line formation was observed. Results of direct detection of Legionella bacteria and L. pneumophila from water tower specimens by this assay showed 100% sensitivity, and 96.6% and 100% specificity, respectively compared with traditional culture, biochemical and serological identification methods. The PCR-ICT hybrid assay does not require sophisticated equipment and was proved to be practically useful in rapid and direct Legionellae detection from environmental water samples.

  17. Multiplex real-time PCR assay for Legionella species.

    PubMed

    Kim, Seung Min; Jeong, Yoojung; Sohn, Jang Wook; Kim, Min Ja

    2015-12-01

    Legionella pneumophila serogroup 1 (sg1) accounts for the majority of infections in humans, but other Legionella species are also associated with human disease. In this study, a new SYBR Green I-based multiplex real-time PCR assay in a single reaction was developed to allow the rapid detection and differentiation of Legionella species by targeting specific gene sequences. Candidate target genes were selected, and primer sets were designed by referring to comparative genomic hybridization data of Legionella species. The Legionella species-specific groES primer set successfully detected all 30 Legionella strains tested. The xcpX and rfbA primers specifically detected L. pneumophila sg1-15 and L. pneumophila sg1, respectively. In addition, this assay was validated by testing clinical samples and isolates. In conclusion, this novel multiplex real-time PCR assay might be a useful diagnostic tool for the rapid detection and differentiation of Legionella species in both clinical and epidemiological studies. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Legionella prevalence in wastewater treatment plants of Taiwan.

    PubMed

    Huang, S W; Hsu, B M; Ma, P H; Chien, K T

    2009-01-01

    Legionella is a bacterium that is ubiquitous in natural and artificial aquatic environments. Some species of Legionella are recognized as opportunistic potential human pathogens. We investigated the distribution of Legionella at seventeen WWTPs throughout Taiwan. Legionella were detected in 10 of the 17 WWTPs (58.8%) and 25 of 41 samples (61.0%). In the integrated, hospital, industrial and domestic wastewater systems were 13/18 (72.2%), 7/12 (58.3%), 2/7 (28.6%) and 3/4 (75.0%) of the samples were positive for Legionella, respectively. The most frequently encountered species were L. donaldsonii and uncultured L. spp., which were both found in 10 samples (24.4% of all samples), then followed by L. lytica (4.9%) and L. pneumophila (4.9%). L. anisa was detected in one sample (2.4%). The results of this survey confirm that Legionella are ubiquitous in WWTPs in Taiwan. Therefore, long-term investigations should be conducted to evaluate the overall occurrence of Legionella in WWTPs in Taiwan.

  19. [The hospital faced with a prolonged Legionella outbreak].

    PubMed

    Fernández, Juan Antonio; Marco, Tomás; Orozco, Domingo; Merino, Jaime

    2004-01-01

    To describe the health resources used in patients hospitalized with Legionella pneumonia during an outbreak of Legionnaire's disease in Alcoy (Spain), and to compare them with those used in other forms of pneumonia. Using a clinical protocol, 177 Legionella pneumonia patients were compared with 180 patients hospitalized for other types of pneumonia. Data on therapy and the resources used were collected. The most common antibiotic treatment in both groups was clarithromycin, but intensive care and mechanical ventilation requirements were greater in Legionella pneumonia. Home-based hospital care was successfully used in 15.6% of patients with Legionella pneumonia and in 11.3% of those with other types of pneumonia. Home oxygen therapy after discharge was less frequent in the Legionella pneumonia group (7.8%) than in the group with non-Legionella pneumonia (16.7%). Notable results were the greater requirement for mechanical ventilation in Legionella pneumonia and the good results obtained by home-based hospital care within current health care management.

  20. Plasmids of ’Legionella’ Species

    DTIC Science & Technology

    1982-03-09

    Legionella , may acquire transposons which code for drug resistance. In view of the narrow spectrum of antibiotics effective in the treatment of diseases...resistance. In view of the narrow spectrum of antibiotics effective in the treatment of diseases caused by Legionella species, the acquisition of plasmid...by the very narrow spectrum of antibiotics effective in the treatment of the disease. We were interested in examining strains of Legionella for i1

  1. [Community-acquired Legionella pneumonia : data from the CAPNETZ study].

    PubMed

    von Baum, H; Lück, C

    2011-06-01

    Legionella are present in the environment as well as in biofilms of water installation systems. Most Legionella live in amoebae. More than 51 different species of Legionella have been identified; however, most pneumonias are caused by Legionella pneumophila serogroup 1. Legionnaire's disease has an incidence of about 4% in Germany. Most cases of Legionnaire's disease are sporadic. Microbiological identification of Legionella can be achieved by cultivation of Legionella spp. on specific media, performing of Legionella-specific PCR from respiratory samples, or Legionella urinary antigen testing. Patients with severe underlying diseases, patients receiving immunosuppression, and patients who are heavy smokers have a predisposition to Legionnaire's disease. Men are significantly more often affected. Whereas outpatients show a mild clinical course, mortality for hospitalized patients is 11.2%. It can be assumed that only a minority of cases of Legionnaire's disease is recognized and reported in Germany.

  2. Legionella Pneumophila and Dendrimers-Mediated Antisense Therapy.

    PubMed

    Pashaei-Asl, Roghiyeh; Khodadadi, Khodadad; Pashaei-Asl, Fatima; Haqshenas, Gholamreza; Ahmadian, Nasser; Pashaiasl, Maryam; Hajihosseini Baghdadabadi, Reza

    2017-06-01

    Finding novel and effective antibiotics for treatment of Legionella disease is a challenging field. Treatment with antibiotics usually cures Legionella infection; however, if the resultant disease is not timely recognized and treated properly, it leads to poor prognosis and high case fatality rate. Legionella pneumophila DrrA protein (Defects in Rab1 recruitment protein A)/also known as SidM affects host cell vesicular trafficking through modification of the activity of cellular small guanosine triphosphatase )GTPase( Rab (Ras-related in brain) function which facilitates intracellular bacterial replication within a supporter vacuole. Also, Legionella pneumophila LepA and LepB (Legionella effector protein A and B) proteins suppress host-cell Rab1 protein's function resulting in the cell lysis and release of bacteria that subsequently infect neighbour cells. Legionella readily develops resistant to antibiotics and, therefore, new drugs with different modes of action and therapeutic strategic approaches are urgently required among antimicrobial drug therapies;gene therapy is a novel approach for Legionnaires disease treatment. On the contrary to the conventional treatment approaches that target bacterial proteins, new treatment interventions target DNA (Deoxyribonucleic acid), RNA (Ribonucleic acid) species, and different protein families or macromolecular complexes of these components. The above approaches can overcome the problems in therapy of Legionella infections caused by antibiotics resistance pathogens. Targeting Legionella genes involved in manipulating cellular vesicular trafficking using a dendrimer-mediated antisense therapy is a promising approach to inhibit bacterial replication within the target cells.

  3. [Pathogenesis, diagnosis and therapy of Legionella infections].

    PubMed

    Lück, P C; Steinert, M

    2006-05-01

    Legionella species are ubiquitous in aquatic environments. About 50 years ago they entered the engineered (technical) environment, i.e. warm water systems with zones of stagnation. Since that time they represent a hygienic problem. After transmission to humans via aerosols legionellae might cause Legionella pneumonia (legionnaires' disease) or influenza-like respiratory infections (Pontiac fever). Epidemiological data suggest that Legionella strains might differ substantially in their virulence properties. Although the molecular basis is not understood L. pneumophila serogroup 1 especially MAb 3/1-positive strains cause the majority of infections. The main virulence feature is the ability to multiply intracellularly. After uptake into macrophages legionellae multiply in a specialized vacuole and finally lyse their host cells. Several bacterial factors like surface components, secretion systems and iron uptake systems are involved in this process. Since the clinical picture of Legionella pneumonia does not allow differentiation from pneumoniae caused by other pathogens, microbiological diagnostic methods are needed to establish the diagnosis. Cultivation of legionellae from clinical specimens, detection of antigens and DNA in patients' samples and detection of antibodies in serum samples are suitable methods. However, none of the diagnostic tests presently available offers the desired quality with respect to sensitivity and specificity. Therefore, the standard technique is to use several diagnostic tests in parallel. Advantages and disadvantages of the diagnostic procedures are discussed. Therapeutic options for Legionella infections are newer macrolides like azithromycin and chinolones (ciprofloxacin, levofloxacin and moxifloxacin).

  4. Dual infections with different Legionella strains.

    PubMed

    Wewalka, G; Schmid, D; Harrison, T G; Uldum, S A; Lück, C

    2014-01-01

    In 2010 a case of a dual infection with Legionella pneumophila serogroup (sg) 1 and sg 3 was identified by culture of a blood sample collected from a female Austrian patient with septic pneumonia. Subsequently all 35 European National Legionella Reference Laboratories were interviewed regarding the frequency of dual infections in legionellosis. The Reference Laboratories in Denmark, the UK and Germany reported the detection of another 14 cases of dual infections with different Legionella strains between 2002 and 2012. Among the 15 cases, there were four cases with different Legionella species, six cases with different L. pneumophila serogroups, and five cases of dual infections with L. pneumophila sg 1 with different MAb-types. The median age of the 15 cases was 56 years and the male to female ratio 1:1.14. Six of the 15 patients were receiving immunosuppressive treatment following organ transplantation (n = 3) or for underlying haematological and solid malignancies (n = 3). Five of the 15 cases died within 30 days following diagnosis. Efforts to detect dual infections with different Legionella strains will improve our ability to correctly elucidate the causative sources of infection and enhance our understanding of the epidemiology of Legionella infections. © 2013 The Authors Clinical Microbiology and Infection © 2013 European Society of Clinical Microbiology and Infectious Diseases.

  5. Legionella confirmation in cooling tower water

    PubMed Central

    Farhat, Maha; Shaheed, Raja A.; Al-Ali, Haidar H.; Al-Ghamdi, Abdullah S.; Al-Hamaqi, Ghadeer M.; Maan, Hawraa S.; Al-Mahfoodh, Zainab A.; Al-Seba, Hussain Z.

    2018-01-01

    Objectives: To investigate the presence of Legionella spp in cooling tower water. Legionella proliferation in cooling tower water has serious public health implications as it can be transmitted to humans via aerosols and cause Legionnaires’ disease. Methods: Samples of cooling tower water were collected from King Fahd Hospital of the University (KFHU) (Imam Abdulrahman Bin Faisal University, 2015/2016). The water samples were analyzed by a standard Legionella culture method, real-time polymerase chain reaction (RT-PCR), and 16S rRNA next-generation sequencing. In addition, the bacterial community composition was evaluated. Results: All samples were negative by conventional Legionella culture. In contrast, all water samples yielded positive results by real-time PCR (105 to 106 GU/L). The results of 16S rRNA next generation sequencing showed high similarity and reproducibility among the water samples. The majority of sequences were Alpha-, Beta-, and Gamma-proteobacteria, and Legionella was the predominant genus. The hydrogen-oxidizing gram-negative bacterium Hydrogenophaga was present at high abundance, indicating high metabolic activity. Sphingopyxis, which is known for its resistance to antimicrobials and as a pioneer in biofilm formation, was also detected. Conclusion: Our findings indicate that monitoring of Legionella in cooling tower water would be enhanced by use of both conventional culturing and molecular methods. PMID:29436561

  6. Legionella prevalence and risk of legionellosis in Japanese households.

    PubMed

    Kuroki, T; Watanabe, Y; Teranishi, H; Izumiyama, S; Amemura-Maekawa, J; Kura, F

    2017-05-01

    This study determined the occurrence of legionellae in private houses for which there were no available data on aquatic environments other than the water supply system. From June 2013 to November 2014, we collected 138 water and 90 swab samples from aquatic environments in 19 houses. Legionella DNA was detected via a loop-mediated isothermal amplification assay in 66 (47·8%) water and 17 (18·9%) swab samples. High Legionella DNA detection rates were observed in water samples from washing machines and aquariums. Legionella spp. was isolated from 9 (6·5%) water and 3 (3·3%) swab samples. Legionella pneumophila SG 1 was detected from the outlet water of a bathtub spout and a bath sponge. Use of amoebic co-culture effectively increased legionellae and Legionella DNA detection rates from all sample types. A logistic regression analysis revealed that the heterotrophic plate count was significantly related to Legionella contamination. Our findings indicate that there is a risk of legionellosis from exposure to Legionella spp. in a variety of aquatic environments in residential houses. Control measures for legionellae in houses should include frequent cleaning and disinfecting to reduce heterotrophic bacteria in water and, where possible, preventing aerosolization from aquatic environments.

  7. Legionella clemsonensis sp. nov.: a green fluorescing Legionella strain from a patient with pneumonia.

    PubMed

    Palmer, Allison; Painter, Joseph; Hassler, Hayley; Richards, Vincent P; Bruce, Terri; Morrison, Shatavia; Brown, Ellen; Kozak-Muiznieks, Natalia A; Lucas, Claressa; McNealy, Tamara L

    2016-10-01

    A novel Legionella species was identified based on sequencing, cellular fatty acid analysis, biochemical reactions, and biofilm characterization. Strain D5610 was originally isolated from the bronchial wash of a patient in Ohio, USA. The bacteria were gram-negative, rod-shaped, and exhibited green fluorescence under long wave UV light. Phylogenetic analysis and fatty acid composition revealed a distinct separation within the genus. The strain grows between 26-45°C and forms biofilms equivalent to L. pneumophila Philadelphia 1. These characteristics suggest that this isolate is a novel Legionella species, for which the name Legionella clemsonensis sp nov. is proposed. © 2016 The Societies and John Wiley & Sons Australia, Ltd.

  8. Legionella waltersii--a novel cause of pneumonia?

    PubMed

    König, Corinne; Hebestreit, Helge; Valenza, Guiseppe; Abele-Horn, Marianne; Speer, Christian P

    2005-10-01

    A 5-y-old girl was admitted to our hospital with fever, cough, respiratory distress and rapidly increasing oxygen requirements. A chest radiograph showed bilateral central infiltrates. PCR was performed with pharyngeal washings and revealed Legionella DNA, while no genetic materials of other pathogens such as respiratory viruses, Mycoplasma and Chlamydia were detected. The clinical condition improved gradually after administration of steroids and therapy with clarithromycin. Further sequencing of Legionella DNA led to the identification of Legionella waltersii. This Legionella species has never been described as a human pathogen before. For the first time, L. waltersii was identified as a cause of severe pneumonia. Since L. waltersii is not detected by routine laboratory tests, it may be speculated that these bacteria, like other Legionella species, are underestimated as a probable cause of community-acquired pneumonia.

  9. Ecological niche of Legionella pneumophila

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fliermans, C.B.

    1983-01-01

    This paper discusses the ecological niches, relationships and controls of Legionella derived from environmental sources. Only as clinical cases and studies relate directly to the ecological understanding of the bacterium will they be discussed. This review seeks to separate the ecological parameters associated with Legionella that are often incorporated into the medical literature as well as to highlight specific ecological studies. A series of ecological studies demonstrates the niches of Legionella, the ecological parameters that allow the bacterium to survive, grow and to be disseminated. Relationships among given habitats are explored along with biological relationships within a given habitat.

  10. Characterization of Legionella Species from Watersheds in British Columbia, Canada

    PubMed Central

    Peabody, Michael A.; Caravas, Jason A.; Morrison, Shatavia S.; Mercante, Jeffrey W.; Prystajecky, Natalie A.; Raphael, Brian H.

    2017-01-01

    ABSTRACT Legionella spp. present in some human-made water systems can cause Legionnaires’ disease in susceptible individuals. Although legionellae have been isolated from the natural environment, variations in the organism’s abundance over time and its relationship to aquatic microbiota are poorly understood. Here, we investigated the presence and diversity of legionellae through 16S rRNA gene amplicon and metagenomic sequencing of DNA from isolates collected from seven sites in three watersheds with varied land uses over a period of 1 year. Legionella spp. were found in all watersheds and sampling sites, comprising up to 2.1% of the bacterial community composition. The relative abundance of Legionella tended to be higher in pristine sites than in sites affected by agricultural activity. The relative abundance levels of Amoebozoa, some of which are natural hosts of legionellae, were similarly higher in pristine sites. Compared to other bacterial genera detected, Legionella had both the highest richness and highest alpha diversity. Our findings indicate that a highly diverse population of legionellae may be found in a variety of natural aquatic sources. Further characterization of these diverse natural populations of Legionella will help inform prevention and control efforts aimed at reducing the risk of Legionella colonization of built environments, which could ultimately decrease the risk of human disease. IMPORTANCE Many species of Legionella can cause Legionnaires’ disease, a significant cause of bacterial pneumonia. Legionella in human-made water systems such as cooling towers and building plumbing systems are the primary sources of Legionnaires’ disease outbreaks. In this temporal study of natural aquatic environments, Legionella relative abundance was shown to vary in watersheds associated with different land uses. Analysis of the Legionella sequences detected at these sites revealed highly diverse populations that included potentially novel

  11. Effect of Common Drinking Water Disinfectants, Chlorine and Heat, on Free Legionella and Amoebae-Associated Legionella.

    PubMed

    Cervero-Aragó, Sílvia; Rodríguez-Martínez, Sarah; Puertas-Bennasar, Antoni; Araujo, Rosa M

    2015-01-01

    Chlorine and thermal treatments are the most commonly used procedures to control and prevent Legionella proliferation in drinking water systems of large buildings. However, cases of legionellosis still occur in facilities with treated water. The purpose of this work was to model the effect of temperature and free chlorine applied in similar exposure conditions as in drinking water systems on five Legionella spp. strains and two amoebal strains of the genera Acanthamoeba. Inactivation models obtained were used to determine the effectiveness of the treatments applied which resulted more effective against Legionella than Acanthamoeba, especially those in cystic stages. Furthermore, to determine the influence of the relationship between L. pneumophila and Acanthamoeba spp. on the treatment effectiveness, inactivation models of the bacteria-associated amoeba were also constructed and compared to the models obtained for the free living bacteria state. The Legionella-amoeba association did not change the inactivation models, but it reduced the effectiveness of the treatments applied. Remarkably, at the lowest free chlorine concentration, 0.5 mg L-1, as well as at the lowest temperatures, 50°C and 55°C, the influence of the Legionella-amoeba associate state was the strongest in reducing the effectiveness of the treatments compared to the free Legionella state. Therefore, the association established between L. pneumophila and amoebae in the water systems indicate an increased health risk in proximal areas of the system (close to the tap) where lower free chlorine concentrations and lower temperatures are commonly observed.

  12. The Flagellar Regulon of Legionella-A Review.

    PubMed

    Appelt, Sandra; Heuner, Klaus

    2017-01-01

    The Legionella genus comprises more than 60 species. In particular, Legionella pneumophila is known to cause severe illnesses in humans. Legionellaceae are ubiquitous inhabitants of aquatic environments. Some Legionellaceae are motile and their motility is important to move around in habitats. Motility can be considered as a potential virulence factor as already shown for various human pathogens. The genes of the flagellar system, regulator and structural genes, are structured in hierarchical levels described as the flagellar regulon. Their expression is modulated by various environmental factors. For L. pneumophila it was shown that the expression of genes of the flagellar regulon is modulated by the actual growth phase and temperature. Especially, flagellated Legionella are known to express genes during the transmissive phase of growth that are involved in the expression of virulence traits. It has been demonstrated that the alternative sigma-28 factor is part of the link between virulence expression and motility. In the following review, the structure of the flagellar regulon of L. pneumophila is discussed and compared to other flagellar systems of different Legionella species. Recently, it has been described that Legionella micdadei and Legionella fallonii contain a second putative partial flagellar system. Hence, the report will focus on flagellated and non-flagellated Legionella strains, phylogenetic relationships, the role and function of the alternative sigma factor (FliA) and its anti-sigma-28 factor (FlgM).

  13. First Case of Legionnaire's Disease Caused by Legionella anisa in Spain and the Limitations on the Diagnosis of Legionella non-pneumophila Infections.

    PubMed

    Vaccaro, Lucianna; Izquierdo, Fernando; Magnet, Angela; Hurtado, Carolina; Salinas, Mireya B; Gomes, Thiago Santos; Angulo, Santiago; Salso, Santiago; Pelaez, Jesús; Tejeda, Maria Isabel; Alhambra, Almudena; Gómez, Carmen; Enríquez, Ana; Estirado, Eva; Fenoy, Soledad; Del Aguila, Carmen

    2016-01-01

    Legionnaires' disease is a severe form of pneumonia, with worldwide relevance, caused by Legionella spp. Approximately 90% of all cases of legionellosis are caused by Legionella pneumophila, but other species can also be responsible for this infection. These bacteria are transmitted by inhalation of aerosols or aspiration of contaminated water. In Spain, environmental studies have demonstrated the presence of Legionella non-pneumophila species in drinking water treatment plants and water distribution networks. Aware that this evidence indicates a risk factor and the lack of routine assays designed to detect simultaneously diverse Legionella species, we analyzed 210 urine samples from patients presenting clinical manifestations of pneumonia using a semi-nested PCR for partial amplification of the 16S rDNA gene of Legionella and a diagnostic method used in hospitals for Legionella antigen detection. In this study, we detected a total of 15 cases of legionellosis (7.1%) and the first case of Legionnaires' disease caused by L. anisa in Spain. While the conventional method used in hospitals could only detect four cases (1.9%) produced by L. pneumophila serogroup 1, using PCR, the following species were identified: Legionella spp. (10/15), L. pneumophila (4/15) and L. anisa (1/15). These results suggest the need to change hospital diagnostic strategies regarding the identification of Legionella species associated with this disease. Therefore, the detection of Legionella DNA by PCR in urine samples seems to be a suitable alternative method for a sensitive, accurate and rapid diagnosis of Legionella pneumonia, caused by L. pneumophila and also for L. non-pneumophila species.

  14. First Case of Legionnaire's Disease Caused by Legionella anisa in Spain and the Limitations on the Diagnosis of Legionella non-pneumophila Infections

    PubMed Central

    Vaccaro, Lucianna; Izquierdo, Fernando; Magnet, Angela; Hurtado, Carolina; Salinas, Mireya A.; Gomes, Thiago Santos; Angulo, Santiago; Salso, Santiago; Pelaez, Jesús; Tejeda, Maria Isabel; Alhambra, Almudena; Gómez, Carmen; Enríquez, Ana; Estirado, Eva; Fenoy, Soledad; del Aguila, Carmen

    2016-01-01

    Legionnaires’ disease is a severe form of pneumonia, with worldwide relevance, caused by Legionella spp. Approximately 90% of all cases of legionellosis are caused by Legionella pneumophila, but other species can also be responsible for this infection. These bacteria are transmitted by inhalation of aerosols or aspiration of contaminated water. In Spain, environmental studies have demonstrated the presence of Legionella non-pneumophila species in drinking water treatment plants and water distribution networks. Aware that this evidence indicates a risk factor and the lack of routine assays designed to detect simultaneously diverse Legionella species, we analyzed 210 urine samples from patients presenting clinical manifestations of pneumonia using a semi-nested PCR for partial amplification of the 16S rDNA gene of Legionella and a diagnostic method used in hospitals for Legionella antigen detection. In this study, we detected a total of 15 cases of legionellosis (7.1%) and the first case of Legionnaires’ disease caused by L. anisa in Spain. While the conventional method used in hospitals could only detect four cases (1.9%) produced by L. pneumophila serogroup 1, using PCR, the following species were identified: Legionella spp. (10/15), L. pneumophila (4/15) and L. anisa (1/15). These results suggest the need to change hospital diagnostic strategies regarding the identification of Legionella species associated with this disease. Therefore, the detection of Legionella DNA by PCR in urine samples seems to be a suitable alternative method for a sensitive, accurate and rapid diagnosis of Legionella pneumonia, caused by L. pneumophila and also for L. non-pneumophila species. PMID:27442238

  15. Plasmids of Legionella Species.

    DTIC Science & Technology

    1982-06-18

    LEGIONELLA SPECIES *PERRY MIKESELL, CPT GREGORY B. KNUDSON, PhD U.S. ARMY MEDICAL RESEARCH INSTITUTE OF INFECTIOUS DISEASES FORT DETRICK, FREDERICK, MARYLAND...sponsible for metabolism, resistan to metals and fertility factors , plasmids also encode for druKg_-sistance factors . These latter genetic elements are an...3). The etiological agent was identified as a fastidious, aerobic, gram-nega- tive bacterium and given the name Legionella pneumophila. The number of

  16. Aerobiology of the built environment: Synergy between Legionella and fungi.

    PubMed

    Alum, Absar; Isaacs, Galahad Zachariah

    2016-09-02

    The modern built environment (BE) design creates unique ecological niches ideal for the survival and mutual interaction of microbial communities. This investigation focused on the synergistic relations between Legionella and the fungal species commonly found in BEs and the impact of these synergistic relationships on the survival and transmission of Legionella. A field study was conducted to identify the types and concentrations of fungi in BEs. The fungal isolates purified from BEs were cocultured with Legionella to study their synergistic association. Cocultured Legionella cells were aerosolized in an air-tight chamber to evaluate the efficacy of ultraviolet (UV) to inactivate these cells. Aspergillus, Alternaria, and Cladosporium were the most common fungi detected in samples that tested positive for Legionella. After coculturing, Legionella cells were detected inside fungal hyphae. The microscopic observations of Legionella internalization in fungal hyphae were confirmed by molecular analyses. UV disinfection of the aerosolized Legionella cells that were cocultured with fungi indicated that fungal spores and propagules act as a shield against UV radiation. The shield effect of fungal spores on Legionella cells was quantified at >2.5 log10. This study provides the first evidence, to our knowledge, of Legionella cell presence inside fungi detected in an indoor environment. This symbiotic relationship with fungi results in longer survival of Legionella under ambient conditions and provides protection against UV rays. Copyright © 2016. Published by Elsevier Inc.

  17. [The clinical value of urinary antigen detection of Legionella pneumonia].

    PubMed

    Jiang, Luxi; Chen, Yu; Xia, Shuyue; Ma, Jiangwei; Zhao, Hongwen; Lu, Ye; Tao, Sixu; Zhao, Li

    2015-01-01

    To investigate the clinical value of urinary antigen detection of Legionella, and to describe the clinical characteristics of Legionella pneumonia. Patients with suspected Legionella pneumonia were enrolled from the Respiratory departments of 3 tertiary hospitals in Shenyang during May 2011 to November 2013. Urinary Legionella antigen was detected for all the enrolled patients. Bacterial culture, polymerase chain reaction (PCR) for Legionella, and double Legionella antibody detection in sera were performed for each patient whose urinary antigen was positive. Patients confirmed to have Legionella pneumonia were pooled and analyzed. Totally 13 cases presenting with pneumonia were positive for Legionella by the urinary antigen method, and in one of them Legionella strain was isolated from the secretion of lower respiratory tract. PCR detection was performed in 8 patients, and 4 of them were positive. Legionella antibody detection was performed in 12 patients, and 7 of them were positive. Nine patients had a history of exposure to Legionella high-risk environments. The characteristics of the cases with Legionella pneumonia were as follows: characteristic orange sputum in 4 patients, digestive symptoms in 6, neurologic disorders in 8, hyponatremia in 10, hypoxia with oxygenation index < 300 mmHg (1 mmHg = 0.133 kPa) in 11, and severe pneumonia with PSI of grade V (PSI score > 130) in 8 patients . Chest CT scan showed bilateral involvement in 6, ground-glass opacity combined with consolidation in 11, and moderate pleural effusion in 11 patients. Cavity and reversed halo sign were found in one case, respectively. All of the patients received fluoroquinolone treatment, and 11 patients recovered completely while 2 died of multiple organ dysfunction syndrome, one of them was complicated with secondary infection. Detection of urinary antigen of Legionella is very useful in the diagnosis of Legionella pneumonia. Attention should be paid to exposure history to the high

  18. Molecular epidemiology, phylogeny and evolution of Legionella.

    PubMed

    Khodr, A; Kay, E; Gomez-Valero, L; Ginevra, C; Doublet, P; Buchrieser, C; Jarraud, S

    2016-09-01

    Legionella are opportunistic pathogens that develop in aquatic environments where they multiply in protozoa. When infected aerosols reach the human respiratory tract they may accidentally infect the alveolar macrophages leading to a severe pneumonia called Legionnaires' disease (LD). The ability of Legionella to survive within host-cells is strictly dependent on the Dot/Icm Type 4 Secretion System that translocates a large repertoire of effectors into the host cell cytosol. Although Legionella is a large genus comprising nearly 60 species that are worldwide distributed, only about half of them have been involved in LD cases. Strikingly, the species Legionella pneumophila alone is responsible for 90% of all LD cases. The present review summarizes the molecular approaches that are used for L. pneumophila genotyping with a major focus on the contribution of whole genome sequencing (WGS) to the investigation of local L. pneumophila outbreaks and global epidemiology studies. We report the newest knowledge regarding the phylogeny and the evolution of Legionella and then focus on virulence evolution of those Legionella species that are known to have the capacity to infect humans. Finally, we discuss the evolutionary forces and adaptation mechanisms acting on the Dot/Icm system itself as well as the role of mobile genetic elements (MGE) encoding T4ASSs and of gene duplications in the evolution of Legionella and its adaptation to different hosts and lifestyles. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Effect of Common Drinking Water Disinfectants, Chlorine and Heat, on Free Legionella and Amoebae-Associated Legionella

    PubMed Central

    Cervero-Aragó, Sílvia; Rodríguez-Martínez, Sarah; Puertas-Bennasar, Antoni; Araujo, Rosa M.

    2015-01-01

    Chlorine and thermal treatments are the most commonly used procedures to control and prevent Legionella proliferation in drinking water systems of large buildings. However, cases of legionellosis still occur in facilities with treated water. The purpose of this work was to model the effect of temperature and free chlorine applied in similar exposure conditions as in drinking water systems on five Legionella spp. strains and two amoebal strains of the genera Acanthamoeba. Inactivation models obtained were used to determine the effectiveness of the treatments applied which resulted more effective against Legionella than Acanthamoeba, especially those in cystic stages. Furthermore, to determine the influence of the relationship between L. pneumophila and Acanthamoeba spp. on the treatment effectiveness, inactivation models of the bacteria-associated amoeba were also constructed and compared to the models obtained for the free living bacteria state. The Legionella-amoeba association did not change the inactivation models, but it reduced the effectiveness of the treatments applied. Remarkably, at the lowest free chlorine concentration, 0.5 mg L-1, as well as at the lowest temperatures, 50°C and 55°C, the influence of the Legionella-amoeba associate state was the strongest in reducing the effectiveness of the treatments compared to the free Legionella state. Therefore, the association established between L. pneumophila and amoebae in the water systems indicate an increased health risk in proximal areas of the system (close to the tap) where lower free chlorine concentrations and lower temperatures are commonly observed. PMID:26241039

  20. Presence of Legionella in London's water supplies.

    PubMed

    Colbourne, J S; Trew, R M

    1986-09-01

    Legionella occurs frequently (52 to 54%) in domestic water and cooling water inside commercial, industrial and health care buildings, and these types of water systems are now regarded as a normal habitat for Legionella. The factors that predispose a particular water system to colonization by these organisms are ill-defined, although it is fairly certain that biological and physicochemical environmental factors play an important role in allowing Legionella to multiply in the circulating water. It has been postulated that the organism may gain access to water systems inside buildings by one of three routes: contact with air through open points such as uncovered storage tanks or vents, ingress of soil or surface water during construction or repair, or intermittent seeding with organisms present in low numbers in the public water supply. Three studies in the USA have found Legionella in 0.4 to 8.8% of drinking-water samples, but these were not representative of the public supply network as a whole. The aim of this study was to determine, over a period of 1 year, the frequency of Legionella in London's drinking water--from the treatment plant through to the consumer's tap. To date, Legionella has not been isolated from raw river water entering London's treatment works or from treated water entering the distribution network. Sixty-two monitoring taps in buildings located in 21 supply areas have been sampled twice for Legionella; only 2 (2.4%) have proved positive during the autumn and winter of 1985/86. The strain found was L. pneumophila serotype 1, subgroup Olda, and the numbers ranged from 10(2) to 10(4)/l. Although the survey is incomplete, it is already clear that the public water supplies in London are not a source of strains of Legionella associated with disease.

  1. Clinical Utility of Testing for Legionella Pneumonia in Central Texas.

    PubMed

    Henry, Christopher; Boethel, Carl; Copeland, Laurel A; Ghamande, Shekhar; Arroliga, Alejandro C; White, Heath D

    2017-01-01

    Legionella pneumophila is an uncommon cause of community-acquired pneumonia in the south central region of the United States, and regular testing may not be cost effective in areas of low incidence. To evaluate the incidence of Legionella in central Texas and to determine the cost effectiveness of Legionella urinary antigen testing. We performed a single-center retrospective cohort study of patients admitted with pneumonia between January 2001 and December 2013. Patients were identified by Binax Legionella urinary antigen and International Classification of Disease, Ninth Revision codes. Demographic characteristics and clinical history of the confirmed Legionella pneumonia cases were obtained by chart review. Descriptive statistics were used to describe patient characteristics. Over 12 years, 5,807 patients with 11,377 admissions for pneumonia were tested for Legionella urinary antigen. A positive Legionella urinary antigen was found in 17 patients. Cumulative incidence during the study period was 0.23%. Among the Legionella-positive patients, intensive care unit admission and median length of stay were 58.8% and 8.5 days, respectively. Most patients (64.7%) met American Thoracic Society criteria for severe pneumonia. All patients empirically received either a macrolide or fluoroquinolone covering Legionella. There were two in-hospital and three total 90-day deaths in those with a positive urinary antigen. The estimated cost of screening this population with Legionella urinary antigen was $214,438 over 13 years. This study reveals the low incidence of Legionella pneumonia in central Texas. Use of guideline-concordant antibiotic treatment provides coverage for Legionella. We speculate that testing in a low-prevalence area would not influence outcomes or be cost effective.

  2. Phylogenetic characterization of Legionella-like endosymbiotic X-bacteria in Amoeba proteus: a proposal for 'Candidatus Legionella jeonii' sp. nov.

    PubMed

    Park, Miey; Yun, Seong Tae; Kim, Mu Soo; Chun, Jongsik; Ahn, Tae In

    2004-12-01

    The X-bacteria which initiated organismic association with the D strain of Amoeba proteus in 1966 as parasites have changed to obligate endosymbionts on which the host depends for survival. Owing to the difficulty in cultivating the bacteria in vitro, the identity of X-bacteria has not been determined. As the life cycle of X-bacteria is similar to that of Legionella spp. in soil amoebae, we applied the polymerase chain reaction method with specific primers aimed at Legionella spp. for the detection and cloning of 16S rRNA gene. The identity and intracellular localization of the endosymbiont were confirmed by the application of a specific fluorescently labelled 16S rRNA-targeted probe. In addition we cloned RNA polymerase beta-subunit gene (rpoB) of X-bacteria by genomic library tagging. A phylogenetic analysis of the 16S rRNA gene placed the bacterium within a unique monophyletic group containing all other members of the genus Legionella. Phylogeny from rpoB and mip genes further confirmed the taxonomic context of X-bacteria to be a Legionella sp. In all three phylogenic analyses, X-bacterium was placed apart from Legionella-like amoebal pathogens present in soil amoebae. Thus, we propose the name 'Candidatus Legionella jeonii' sp. nov. for the endosymbiotic X-bacteria in Amoeba proteus.

  3. Acquired Fanconi syndrome in patients with Legionella pneumonia.

    PubMed

    Kinoshita-Katahashi, Naoko; Fukasawa, Hirotaka; Ishigaki, Sayaka; Isobe, Shinsuke; Imokawa, Shiro; Fujigaki, Yoshihide; Furuya, Ryuichi

    2013-08-02

    Hyponatremia is often observed in patients with Legionella pneumonia. However, other electrolyte abnormalities are uncommon and the mechanism remains to be clarified. We experienced two male cases of acquired Fanconi syndrome associated with Legionella pneumonia. The laboratory findings at admission showed hypophosphatemia, hypokalemia, hypouricemia and/or hyponatremia. In addition, they had the generalized dysfunction of the renal proximal tubules presenting decreased tubular reabsorption of phosphate (%TRP), increased fractional excretion of potassium (FEK) and uric acid (FEUA), low-molecular-weight proteinuria, panaminoaciduria and glycosuria. Therefore, they were diagnosed as Fanconi syndrome. Treatment for Legionella pneumonia with antibiotics resulted in the improvement of all serum electrolyte abnormalities and normalization of the %TRP, FEK, FEUA, low-molecular-weight proteinuria, panaminoaciduria and glycosuria, suggesting that Legionella pneumophila infection contributed to the pathophysiology of Fanconi syndrome. To the best of our knowledge, this is the first report demonstrating Fanconi syndrome associated with Legionella pneumonia.

  4. Legionella spp. and Legionnaires' disease.

    PubMed

    Diederen, B M W

    2008-01-01

    Infection with Legionella spp. is an important cause of community- and hospital-acquired pneumonia, occurring both sporadically and in outbreaks. Infection with Legionella spp. ranks among the three most common causes of severe pneumonia in the community setting, and is isolated in 1-40% of cases of hospital-acquired pneumonia. There are no clinical features unique to Legionnaires' disease. Macrolides and fluoroquinolones are the most widely used drugs in treatment. The availability of a good diagnostic repertoire, suitable for accurately diagnosing LD, constitutes the basis for the early recognition and treatment of the individual patient as well as for effective measures for prevention and control. This review summarizes the available information regarding the microbiology, clinical presentation, diagnosis and treatment of LD, with an emphasis on the laboratory diagnosis of infection with Legionella spp.

  5. Effect of UV irradiation (253.7 nm) on free Legionella and Legionella associated with its amoebae hosts.

    PubMed

    Cervero-Aragó, Sílvia; Sommer, Regina; Araujo, Rosa M

    2014-12-15

    Water systems are the primary reservoir for Legionella spp., where the bacteria live in association with other microorganisms, such as free-living amoebae. A wide range of disinfection treatments have been studied to control and prevent Legionella colonization but few of them were performed considering its relation with protozoa. In this study, the effectiveness of UV irradiation (253.7 nm) using low-pressure lamps was investigated as a disinfection method for Legionella and amoebae under controlled laboratory conditions. UV treatments were applied to 5 strains of Legionella spp., 4 strains of free-living amoeba of the genera Acanthamoeba and Vermamoeba, treating separately trophozoites and cysts, and to two different co-cultures of Legionella pneumophila with the Acanthamoeba strains. No significant differences in the UV inactivation behavior were observed among Legionella strains tested which were 3 logs reduced for fluences around 45 J/m(2). UV irradiation was less effective against free-living amoebae; which in some cases required up to 990 J/m(2) to obtain the same population reduction. UV treatment was more effective against trophozoites compared to cysts; moreover, inactivation patterns were clearly different between the genus Acanthamoeba and Vermamoeba. For the first time data about Vermamoeba vermiformis UV inactivation has been reported in a study. Finally, the results showed that the association of L. pneumophila with free-living amoebae decreases the effectiveness of UV irradiation against the bacteria in a range of 1.5-2 fold. That fact demonstrates that the relations established between different microorganisms in the water systems can modify the effectiveness of the UV treatments applied. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. An update on Legionella.

    PubMed

    Carratalà, Jordi; Garcia-Vidal, Carolina

    2010-04-01

    Legionella pneumophila is increasingly recognized as a significant cause of sporadic and epidemic community-acquired and nosocomial-acquired pneumonia. This review focuses on the latest literature concerning the epidemiology, pathogenesis, clinical presentation, diagnosis, and treatment of Legionnaires' disease. A significant increase in the incidence of Legionnaires' disease in the United States has been documented over the last years. L. pneumophila has recently been found to be a leading cause of community-acquired pneumonia in hospitalized and ambulatory patients in Germany. Recent studies provide insight into the understanding of the pathogenesis of Legionnaires' disease and the relevance of the formation of biofilms. Clinical manifestations of Legionnaires' disease are not specific and current diagnostic scores are of limited use. Several recent studies offer useful information concerning Legionnaires' disease in immunosuppressed patients. A systematic review of English literature performed to assess test characteristics of Legionella urinary antigen has found that the pooled sensitivity of the test was 0.74 and specificity was 0.991. Improved clinical response has been observed for patients with Legionnaires' disease treated with highly active antimicrobial agents against Legionella. Legionnaires' disease is a significant health problem in many countries. Clinical manifestations are unreliable in diagnosing Legionnaires' disease. Therefore, diagnostic laboratory tests for Legionella, including the urinary antigen test, should be applied to all patients with pneumonia. Levofloxacin (or other fluoroquinolone) or azithromycin are the current drugs of choice for treatment of Legionnaires' disease. Effective preventive strategies are needed.

  7. Legionella spp. in dental unit waterlines.

    PubMed

    Sedlata Juraskova, E; Sedlackova, H; Janska, J; Holy, O; Lalova, I; Matouskova, I

    2017-01-01

    To determine the current presence of Legionella spp. in the output water of dental unit waterlines (DUWLs) and examine its mitigation by disinfection at the Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital Olomouc. The first stage of our survey involved collecting samples of DUWL output water from 50 dental chair units (DCUs), and 2 samples of the incoming potable water. In October 2015, a one-time disinfection (1 % Stabimed) of DUWLs was conducted. This was followed by collecting 10 control samples (survey stage 2). From the total of 50 samples (survey stage 1), 18 samples (36.0 %) tested positive for Legionella spp. Following the disinfection, nine of the ten samples no longer showed any presence of Legionella. Based on culture results, the one-time disinfection (1 % Stabimed) was effective. We are unable to comment on the duration of positive effect of disinfection on the occurrence of Legionella spp. in the outlet water. It was a one-time survey (Tab. 2, Ref. 32).

  8. Isolation of Legionella pneumophila from hotels of Greece.

    PubMed

    Alexiou, S D; Antoniadis, A; Papapaganagiotou, J; Stefanou, T

    1989-03-01

    Twenty water samples collected from 6 hotels situated in various areas of Greece were examined for the presence of Legionella pneumophila and Legionella-like organisms. Five of the six hotels included in this investigation were associated with cases of legionellosis. Legionella pneumophila serogroups 1 and 8 were isolated from four of six hotels, mainly from the hot water supply system. This is the first isolation and identification of L. pneumophila in Greece.

  9. Comparative analysis of Legionella pneumophila and Legionella micdadei virulence traits.

    PubMed

    Joshi, A D; Swanson, M S

    1999-08-01

    While the majority of Legionnaire's disease has been attributed to Legionella pneumophila, Legionella micdadei can cause a similar infection in immunocompromised people. Consistent with its epidemiological profile, the growth of L. micdadei in cultured macrophages is less robust than that of L. pneumophila. To identify those features of the Legionella spp. which are correlated to efficient growth in macrophages, two approaches were taken. First, a phenotypic analysis compared four clinical isolates of L. micdadei to one well-characterized strain of L. pneumophila. Seven traits previously correlated with the virulence of L. pneumophila were evaluated: infection and replication in cultured macrophages, evasion of phagosome-lysosome fusion, contact-dependent cytotoxicity, sodium sensitivity, osmotic resistance, and conjugal DNA transfer. By nearly every measure, L. micdadei appeared less virulent than L. pneumophila. The surprising exception was L. micdadei 31B, which evaded lysosomes and replicated in macrophages as efficiently as L. pneumophila, despite lacking both contact-dependent cytopathicity and regulated sodium sensitivity. Second, in an attempt to identify virulence factors genetically, an L. pneumophila genomic library was screened for clones which conferred robust intracellular growth on L. micdadei. No such loci were isolated, consistent with the multiple phenotypic differences observed for the two species. Apparently, L. pneumophila and L. micdadei use distinct strategies to colonize alveolar macrophages, causing Legionnaire's disease.

  10. Comparative Analysis of Legionella pneumophila and Legionella micdadei Virulence Traits

    PubMed Central

    Joshi, Amrita D.; Swanson, Michele S.

    1999-01-01

    While the majority of Legionnaire’s disease has been attributed to Legionella pneumophila, Legionella micdadei can cause a similar infection in immunocompromised people. Consistent with its epidemiological profile, the growth of L. micdadei in cultured macrophages is less robust than that of L. pneumophila. To identify those features of the Legionella spp. which are correlated to efficient growth in macrophages, two approaches were taken. First, a phenotypic analysis compared four clinical isolates of L. micdadei to one well-characterized strain of L. pneumophila. Seven traits previously correlated with the virulence of L. pneumophila were evaluated: infection and replication in cultured macrophages, evasion of phagosome-lysosome fusion, contact-dependent cytotoxicity, sodium sensitivity, osmotic resistance, and conjugal DNA transfer. By nearly every measure, L. micdadei appeared less virulent than L. pneumophila. The surprising exception was L. micdadei 31B, which evaded lysosomes and replicated in macrophages as efficiently as L. pneumophila, despite lacking both contact-dependent cytopathicity and regulated sodium sensitivity. Second, in an attempt to identify virulence factors genetically, an L. pneumophila genomic library was screened for clones which conferred robust intracellular growth on L. micdadei. No such loci were isolated, consistent with the multiple phenotypic differences observed for the two species. Apparently, L. pneumophila and L. micdadei use distinct strategies to colonize alveolar macrophages, causing Legionnaire’s disease. PMID:10417184

  11. Surveillance of parasitic Legionella in surface waters by using immunomagnetic separation and amoebae enrichment

    PubMed Central

    Hsu, Tsui-Kang; Wu, Shu-Fen; Hsu, Bing-Mu; Kao, Po-Min; Tao, Chi-Wei; Shen, Shu-Min; Ji, Wen-Tsai; Huang, Wen-Chien; Fan, Cheng-Wei

    2015-01-01

    Free-living amoebae (FLA) are potential reservoirs of Legionella in aquatic environments. However, the parasitic relationship between various Legionella and amoebae remains unclear. In this study, surface water samples were gathered from two rivers for evaluating parasitic Legionella. Warmer water temperature is critical to the existence of Legionella. This result suggests that amoebae may be helpful in maintaining Legionella in natural environments because warmer temperatures could enhance parasitisation of Legionella in amoebae. We next used immunomagnetic separation (IMS) to identify extracellular Legionella and remove most free Legionella before detecting the parasitic ones in selectively enriched amoebae. Legionella pneumophila was detected in all the approaches, confirming that the pathogen is a facultative amoebae parasite. By contrast, two obligate amoebae parasites, Legionella-like amoebal pathogens (LLAPs) 8 and 9, were detected only in enriched amoebae. However, several uncultured Legionella were detected only in the extracellular samples. Because the presence of potential hosts, namely Vermamoeba vermiformis, Acanthamoeba spp. and Naegleria gruberi, was confirmed in the samples that contained intracellular Legionella, uncultured Legionella may survive independently of amoebae. Immunomagnetic separation and amoebae enrichment may have referential value for detecting parasitic Legionella in surface waters. PMID:26373823

  12. Surveillance of parasitic Legionella in surface waters by using immunomagnetic separation and amoebae enrichment.

    PubMed

    Hsu, Tsui-Kang; Wu, Shu-Fen; Hsu, Bing-Mu; Kao, Po-Min; Tao, Chi-Wei; Shen, Shu-Min; Ji, Wen-Tsai; Huang, Wen-Chien; Fan, Cheng-Wei

    2015-01-01

    Free-living amoebae (FLA) are potential reservoirs of Legionella in aquatic environments. However, the parasitic relationship between various Legionella and amoebae remains unclear. In this study, surface water samples were gathered from two rivers for evaluating parasitic Legionella. Warmer water temperature is critical to the existence of Legionella. This result suggests that amoebae may be helpful in maintaining Legionella in natural environments because warmer temperatures could enhance parasitisation of Legionella in amoebae. We next used immunomagnetic separation (IMS) to identify extracellular Legionella and remove most free Legionella before detecting the parasitic ones in selectively enriched amoebae. Legionella pneumophila was detected in all the approaches, confirming that the pathogen is a facultative amoebae parasite. By contrast, two obligate amoebae parasites, Legionella-like amoebal pathogens (LLAPs) 8 and 9, were detected only in enriched amoebae. However, several uncultured Legionella were detected only in the extracellular samples. Because the presence of potential hosts, namely Vermamoeba vermiformis, Acanthamoeba spp. and Naegleria gruberi, was confirmed in the samples that contained intracellular Legionella, uncultured Legionella may survive independently of amoebae. Immunomagnetic separation and amoebae enrichment may have referential value for detecting parasitic Legionella in surface waters.

  13. Vectorial role of Acanthamoeba in Legionella propagation in water for human use.

    PubMed

    Magnet, A; Peralta, R H S; Gomes, T S; Izquierdo, F; Fernandez-Vadillo, C; Galvan, A L; Pozuelo, M J; Pelaz, C; Fenoy, S; Del Águila, C

    2015-02-01

    Legionella spp. is the causative agent of Legionnaires' disease and is transmitted through aerosols emanating from man-made water systems. Legionella resistance to water treatments has been related to its association with environmental amoebae such as Acanthamoeba. Due to the high presence of this protozoon in Spain and the high rate of notification of Legionnaires' disease of this country, the aims of this work were to study the coexistence of these bacteria and protozoa in water as well as their interaction. The usefulness of Acanthamoeba co-culture for the isolation of environmental Legionella was also studied. For this purpose, 70 water samples were collected in 2011 from three Drinking Water Treatment Plants, three Wastewater Treatment Plants and five Natural Pools in Spain. Acanthamoeba was found by PCR in 87.1% (61/70) samples and, by culture in 85.7% (60/70) samples. Legionella was detected by PCR in 58.6% (41/70) of water samples, in 5.7% (4/70) by agar culture and 75.7% (53/70) by Acanthamoeba co-culture. From the 54 Acanthamoeba water isolates, Legionella was detected in 43 of them independently of Acanthamoeba's genotype (T3, T4 and T11). Legionella feeleii, Legionella birminghamiensis, Legionella gresilensis/berliardensis, Legionella fairfieldensis, Legionella drozanski and Legionella falloni were identified. In conclusion, our results showed that environmental Acanthamoeba is infected by Legionella to a high percentage, and due to its ubiquity, high resistance and its pathogenic potential per se, new methods for its elimination should be studied. Also, the high effectivity of Acanthamoeba co-culture for Legionella detection has been shown. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Adrenergic antagonists restrict replication of Legionella.

    PubMed

    Harrison, Christopher F; Kicka, Sébastien; Kranjc, Agata; Finsel, Ivo; Chiriano, Gianpaolo; Ouertatani-Sakouhi, Hajer; Soldati, Thierry; Scapozza, Leonardo; Hilbi, Hubert

    2015-07-01

    Legionella pneumophila is a facultative intracellular bacterium, which upon inhalation can cause a potentially fatal pneumonia termed Legionnaires' disease. The opportunistic pathogen grows in environmental amoebae and mammalian macrophages within a unique membrane-bound compartment, the 'Legionella-containing vacuole'. Bacteria are exposed to many environmental cues including small signalling molecules from eukaryotic cells. A number of pathogenic bacteria sense and respond to catecholamine hormones, such as adrenalin and noradrenalin, a process mediated via the QseBC two-component system in some bacteria. In this study, we examined the effect of adrenergic compounds on L. pneumophila, and discovered that the adrenergic receptor antagonists benoxathian, naftopidil, propranolol and labetalol, as well as the QseC sensor kinase inhibitor LED209, reduced the growth of L. pneumophila in broth or amoebae, while replication in macrophages was enhanced. Growth restriction was common to members of the genus Legionella and Mycobacterium, and was observed for L. pneumophila in the replicative but not stationary phase of the biphasic life cycle. Deletion of the L. pneumophila qseBC genes indicated that growth inhibition by adrenergics or LED209 is mediated only to a minor extent by this two-component system, implying the presence of other adrenergic sensing systems. This study identifies adrenergic molecules as novel inhibitors of extra- and intracellular growth of Legionella and reveals LED209 as a potential lead compound to combat infections with Legionella or Mycobacterium spp.

  15. Water quality parameters associated with prevalence of Legionella in hot spring facility water bodies.

    PubMed

    Huang, Shih-Wei; Hsu, Bing-Mu; Wu, Shu-Fen; Fan, Cheng-Wei; Shih, Feng-Cheng; Lin, Yung-Chang; Ji, Dar-Der

    2010-09-01

    Some species of Legionella are recognized as opportunistic potential human pathogens, such as Legionella pneumophila, which causes legionnaires disease. Indeed, outbreaks of legionellosis are frequently reported in areas in which the organism has been spread via aerosols from contaminated institutional water systems. Contamination in hot tubs, spas and public baths are also possible. As a result, in this study, we investigated the distribution of Legionella at six hot spring recreation areas throughout Taiwan. Legionella were detected in all six hot spring recreation areas, as well as in 20 of the 72 samples that were collected (27.8%). Seven species of Legionella identified from samples by the direct DNA extraction method were unidentified Legionella spp., Legionella anisa, L. pneumophila, Legionella erythra, Legionella lytica, Legionella gresilensis and Legionella rubrilucen. Three species of Legionella identified in the samples using the culture method were L. pneumophila, unidentified Legionella spp. and L. erythra. Legionella species were found in water with temperatures ranging from 22.7 °C to 48.6 °C. The optimal pH appeared to range from 5.0 to 8.0. Taken together, the results of this survey confirmed the ubiquity of Legionella in Taiwan spring recreational areas. Therefore, a long-term investigation of the health of workers at hot spring recreational areas and the occurrence of Legionella in hot spring recreational areas throughout Taiwan are needed. Copyright © 2010 Elsevier Ltd. All rights reserved.

  16. Eliminating Legionella by inhibiting BCL-XL to induce macrophage apoptosis.

    PubMed

    Speir, Mary; Lawlor, Kate E; Glaser, Stefan P; Abraham, Gilu; Chow, Seong; Vogrin, Adam; Schulze, Keith E; Schuelein, Ralf; O'Reilly, Lorraine A; Mason, Kylie; Hartland, Elizabeth L; Lithgow, Trevor; Strasser, Andreas; Lessene, Guillaume; Huang, David C S; Vince, James E; Naderer, Thomas

    2016-02-24

    Human pathogenic Legionella replicate in alveolar macrophages and cause a potentially lethal form of pneumonia known as Legionnaires' disease(1). Here, we have identified a host-directed therapeutic approach to eliminate intracellular Legionella infections. We demonstrate that the genetic deletion, or pharmacological inhibition, of the host cell pro-survival protein BCL-XL induces intrinsic apoptosis of macrophages infected with virulent Legionella strains, thereby abrogating Legionella replication. BCL-XL is essential for the survival of Legionella-infected macrophages due to bacterial inhibition of host-cell protein synthesis, resulting in reduced levels of the short-lived, related BCL-2 pro-survival family member, MCL-1. Consequently, a single dose of a BCL-XL-targeted BH3-mimetic therapy, or myeloid cell-restricted deletion of BCL-XL, limits Legionella replication and prevents lethal lung infections in mice. These results indicate that repurposing BH3-mimetic compounds, originally developed to induce cancer cell apoptosis, may have efficacy in treating Legionnaires' and other diseases caused by intracellular microbes.

  17. Legionella risk assessment in cruise ships and ferries.

    PubMed

    Laganà, Pasqualina; Gambuzza, Maria Elsa; Delia, Santi

    2017-06-12

    Introduction. The increasing development of marine traffic has led to a rise in the incidence of legionellosis among travellers. It occurs in similar environments, especially closed and crowded, and aboard ships Legionella survives and multiplies easily in water pipes, spreading into the environment through air conditioning systems and water distribution points. Although in recent years in the construction of cruise ships preventive measures aimed at curbing the proliferation of Legionella (design, materials, focus on the operation and maintenance of the water system), have been taken account, little or no attention has been paid to small ships which, in many cases, are old and not well maintained. Objective. The aim of the study was to evaluate the frequency and severity of Legionella contamination in ferries and cruise ships in order to adopt more specific control measures. Materials and method. A prevalence study was carried out on 10 ferries and 6 cruise ships docking or in transit across the port of Messina (Sicily, Italy). Water and air samples collected from many critical points were tested for qualitative and quantitative identification of Legionella. Results and conclusions. Legionella pneumophila sg 1 was isolated from the samples of shower and tap water in 7 (70%) of the 10 ferries examined, and in 3 (33%) of the 6 cruise ships examined, and L. pneumophila sg 2-14 in 8 (80%) and 1 (16.7%) of these ships, respectively. No Legionella contamination was found in whirlpool baths, air and ice samples. In conclusion, the data obtained confirm higher levels of Legionella contamination in local ferries and cruise ships, underlining the need to adopt corrective actions more specific for these smaller vessels.

  18. Population structure of Legionella spp. from environmental samples in Gabon, 2013.

    PubMed

    Ehrhardt, Jonas; Alabi, Abraham S; Kuczius, Thorsten; Tsombeng, Francis Foguim; Becker, Karsten; Kremsner, Peter G; Schaumburg, Frieder; Esen, Meral

    2015-07-01

    Aquatic environments are the most important source for Legionella spp. infections such as Legionnaires' disease and Pontiac fever. The reservoirs of Legionella spp. are mostly unclear in sub-Saharan Africa. The aim of this study, conducted in 2013, was to identify geographical areas of an increased risk for exposure to Legionella spp., and to describe the population structure of Legionella spp. from different water sources in a cross-sectional study in Gabon. Fresh water samples (n = 200) were cultured on Legionella selective agar; species were confirmed by MALDI-TOF, a Legionella pneumophila specific real-time PCR and 16S RNA gene sequencing. Serogroups were identified by agglutination test. The population structure was assessed by multilocus sequence typing (MLST). Legionella spp. isolates (n = 29) were frequently found in the hospital setting particularly in hot water systems. Open water bodies (i.e. rivers, lakes) were not contaminated with Legionella spp. Isolated L. pneumophila mainly belonged to serogroups 2-14 (n = 19) and MLST sequence type ST1, ST75 (and related STs) and ST1911. In conclusion, hospitalized patients might have an increased risk to become infected with Legionella spp. in the studied areas in Gabon, particularly if they have risk factors such as comorbidities. Both broadly extended (ST1, ST75) and local lineages (ST1911) were present in our setting. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Trend of Legionella colonization in hospital water supply.

    PubMed

    D'Alessandro, D; Fabiani, M; Cerquetani, F; Orsi, G B

    2015-01-01

    In many nosocomial Legionella outbreaks water distribution systems are the most frequent source of infection. Considering the hospital waterline old age, an investigation on colonization by Legionella spp was carried out in order to evaluate the pipeline system weaknesses and to implement environmental preventive measures. From 2004 to 2010, overall 97 samples from the water line were collected. The samples were analyzed according to the italian Legionella spp standard methods; water temperature, pH and residual free chlorine were determined at the time of collection. X2 test, exact-test and t-test were used to compare proportions and means. Overall 28 samples (23.7%) were positive for Legionella spp, and five of them (17.9%) exceeded the threshold level >104 cfu/L. The number of positive samples varied along the years, showing a significant increasing trend (X2 for trend = 11.5; p<0.01), but most occurred in 2008 (53,6%), when the hospital underwent major building reconstruction. Samples positive for Legionella spp by comparison to negative ones showed a lower free chlorine concentration (0.08 mg/L vs 0.15 mg/L) and a higher water temperature (46.1° vs 42.7°). Actually the percentage of positive samples decreased significantly with the increasing in free chlorine in the water (X2 for trend = 8.53; p<0.01). The samples collected at the connection between public water line with the hospital supply network were always free from Legionella. All hospital buildings were colonized by Legionella spp, although 80% of samples >104 cfu/L occurred in the C-building. No cases of nosocomial legionellosis were reported during the study period. Hospital water system showed a diffuse colonization by Legionella spp, although the degree of contamination reached the threshold level (>104 cfu/L) only in a small percentage of samples, showing a substantial effectiveness of the control measures applied.

  20. [Isolation of Legionella species from hot springs used for foot-soaking].

    PubMed

    Furuhata, Katsunori; Edagawa, Akiko; Fukuyama, Masafumi

    2012-05-01

    We aimed to investigate the presence of Legionella species in hot-spring baths for feet, which have been rapidly increasing in number in Japan in recent years. The investigations were conducted between March 2009 and November 2011, and hot springs throughout the country were sampled. Legionella isolates were confirmed on the basis of the method described in the "Manual for the countermeasure to legionellosis, 3rd Edition." In this method, the samples were concentrated and smeared on GVPCalpha agar medium after acid treatment and cultured for 7 days at 36 degrees C. Gram-negative rods that required L-cysteine were determined to be Legionella species. After the first identification using Duopath Legionella (Merck Ltd. Japan), isolates were identified on the basis of agglutination reaction of an immune serum or genetic examination. Legionella was isolated from 56 of the 196 samples (28.6%) and was confirmed to widely inhabit hot-spring baths from Hokkaido to Kyushu. The isolation rates were the highest (40.9%) in facilities installed around railway stations, including those on platforms. The average microbial density of Legionella species per 100 ml of hot spring water was 1.0 x 10(1) CFU, with a maximum value of 1.0 x 10(4) CFU, although the microbial density in most of the samples (34 samples; 60.7%) was less than 10(2) CFU. Legionella pneumophila was the dominant strain, and 16 strains (23.9%) of serogroup 1 were isolated. In addition, 7 strains (10.4%) of Legionella londiniensis and 4 strains (6.0%) of Legionella rubrilucens were isolated. Legionella species inhabit approximately 30% of all hot springs for foot-soaking in the country. Although the number of viable organisms is small, the dominant presence of Legionella pneumophila, a major pathogen responsible for legionnaire's disease, raises the possibility of legionnaire's disease in users of these hot springs. Therefore, each institute should understand the present distribution of Legionella species in these

  1. Recurrent Soft Tissue Abscesses Caused by Legionella cincinnatiensis

    PubMed Central

    Gubler, Jacques G. H.; Schorr, Mirjam; Gaia, V.; Zbinden, R.; Altwegg, M.

    2001-01-01

    Recurrent soft tissue abscesses of the jaw, wrist, and arm developed in a 73-year-old housewife with nephrotic syndrome and immunoglobulin A(κ) gammopathy of unknown etiology. Conventional cultures remained negative, despite visible gram-negative rods on microscopy. Broad-spectrum PCR revealed Legionella cincinnatiensis, which was confirmed by isolation of the organism on special Legionella medium. Infections due to Legionella species outside the lungs are rare. L. cincinnatiensis has been implicated in only four cases of clinical infection; these involved the lungs in three patients and the central nervous system in one patient. We conclude that broad-spectrum PCR can be a valuable tool for the evaluation of culture-negative infections with a high probability of bacterial origin and that Legionella might be an underdiagnosed cause of pyogenic soft tissue infection. PMID:11724886

  2. Rainfall is a risk factor for sporadic cases of Legionella pneumophila pneumonia.

    PubMed

    Garcia-Vidal, Carolina; Labori, Maria; Viasus, Diego; Simonetti, Antonella; Garcia-Somoza, Dolors; Dorca, Jordi; Gudiol, Francesc; Carratalà, Jordi

    2013-01-01

    It is not known whether rainfall increases the risk of sporadic cases of Legionella pneumonia. We sought to test this hypothesis in a prospective observational cohort study of non-immunosuppressed adults hospitalized for community-acquired pneumonia (1995-2011). Cases with Legionella pneumonia were compared with those with non-Legionella pneumonia. Using daily rainfall data obtained from the regional meteorological service we examined patterns of rainfall over the days prior to admission in each study group. Of 4168 patients, 231 (5.5%) had Legionella pneumonia. The diagnosis was based on one or more of the following: sputum (41 cases), antigenuria (206) and serology (98). Daily rainfall average was 0.556 liters/m(2) in the Legionella pneumonia group vs. 0.328 liters/m(2) for non-Legionella pneumonia cases (p = 0.04). A ROC curve was plotted to compare the incidence of Legionella pneumonia and the weighted median rainfall. The cut-off point was 0.42 (AUC 0.54). Patients who were admitted to hospital with a prior weighted median rainfall higher than 0.42 were more likely to have Legionella pneumonia (OR 1.35; 95% CI 1.02-1.78; p = .03). Spearman Rho correlations revealed a relationship between Legionella pneumonia and rainfall average during each two-week reporting period (0.14; p = 0.003). No relationship was found between rainfall average and non-Legionella pneumonia cases (-0.06; p = 0.24). As a conclusion, rainfall is a significant risk factor for sporadic Legionella pneumonia. Physicians should carefully consider Legionella pneumonia when selecting diagnostic tests and antimicrobial therapy for patients presenting with CAP after periods of rainfall.

  3. Native valve endocarditis due to a novel strain of Legionella.

    PubMed

    Pearce, Meghan M; Theodoropoulos, Nicole; Noskin, Gary A; Flaherty, John P; Stemper, Mary E; Aspeslet, Teresa; Cianciotto, Nicholas P; Reed, Kurt D

    2011-09-01

    Legionellae are Gram-negative bacteria which are capable of causing disease, most commonly in the form of pneumonia. We describe a case of native valve endocarditis caused by a Legionella strain which by genotypic (16S rRNA and mip gene sequencing) and phenotypic analyses is unlike previously described strains of Legionella.

  4. Spatial distribution of Legionella pneumophila MLVA-genotypes in a drinking water system.

    PubMed

    Rodríguez-Martínez, Sarah; Sharaby, Yehonatan; Pecellín, Marina; Brettar, Ingrid; Höfle, Manfred; Halpern, Malka

    2015-06-15

    Bacteria of the genus Legionella cause water-based infections, resulting in severe pneumonia. To improve our knowledge about Legionella spp. ecology, its prevalence and its relationships with environmental factors were studied. Seasonal samples were taken from both water and biofilm at seven sampling points of a small drinking water distribution system in Israel. Representative isolates were obtained from each sample and identified to the species level. Legionella pneumophila was further determined to the serotype and genotype level. High resolution genotyping of L. pneumophila isolates was achieved by Multiple-Locus Variable number of tandem repeat Analysis (MLVA). Within the studied water system, Legionella plate counts were higher in summer and highly variable even between adjacent sampling points. Legionella was present in six out of the seven selected sampling points, with counts ranging from 1.0 × 10(1) to 5.8 × 10(3) cfu/l. Water counts were significantly higher in points where Legionella was present in biofilms. The main fraction of the isolated Legionella was L. pneumophila serogroup 1. Serogroup 3 and Legionella sainthelensis were also isolated. Legionella counts were positively correlated with heterotrophic plate counts at 37 °C and negatively correlated with chlorine. Five MLVA-genotypes of L. pneumophila were identified at different buildings of the sampled area. The presence of a specific genotype, "MLVA-genotype 4", consistently co-occurred with high Legionella counts and seemed to "trigger" high Legionella counts in cold water. Our hypothesis is that both the presence of L. pneumophila in biofilm and the presence of specific genotypes, may indicate and/or even lead to high Legionella concentration in water. This observation deserves further studies in a broad range of drinking water systems to assess its potential for general use in drinking water monitoring and management. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Susceptibility of Legionella Strains to the Chlorinated Biocide, Monochloramine

    PubMed Central

    Jakubek, Delphine; Guillaume, Carole; Binet, Marie; Leblon, Gérard; DuBow, Michael; Le Brun, Matthieu

    2013-01-01

    Members of the Legionella genus find suitable conditions for their growth and survival in nuclear power plant cooling circuits. To limit the proliferation of Legionella pathogenic bacteria in nuclear power plant cooling circuits, and ensure that levels remain below regulatory thresholds, monochloramine treatment can be used. Although the treatment is highly effective, i.e. it reduces Legionella numbers by over 99%, Legionella bacteria can still be detected at low concentrations and rapid re-colonisation of circuits can occur after the treatment has ceased. The aim of this study was to develop an in vitro methodology for determining the intrinsic susceptibility of L. pneumophila strains, collected from various nuclear power plant cooling circuits subjected to different treatment conditions. The methodology was developed by using an original approach based on response surface methodology (RSM) combined with a multifactorial experimental design. The susceptibility was evaluated by the Ct factor. The susceptibility of environmental strains varies widely and is, for some strains, greater than that of known tolerant species; however, strain susceptibility was not related to treatment conditions. Selection pressure induced by monochloramine use did not result in the selection of more tolerant Legionella strains and did not explain the detection of Legionella during treatment or the rapid re-colonisation of cooling circuits after disinfection has ceased. PMID:24005820

  6. Susceptibility of Legionella strains to the chlorinated biocide, monochloramine.

    PubMed

    Jakubek, Delphine; Guillaume, Carole; Binet, Marie; Leblon, Gérard; DuBow, Michael; Le Brun, Matthieu

    2013-01-01

    Members of the Legionella genus find suitable conditions for their growth and survival in nuclear power plant cooling circuits. To limit the proliferation of Legionella pathogenic bacteria in nuclear power plant cooling circuits, and ensure that levels remain below regulatory thresholds, monochloramine treatment can be used. Although the treatment is highly effective, i.e. it reduces Legionella numbers by over 99%, Legionella bacteria can still be detected at low concentrations and rapid re-colonisation of circuits can occur after the treatment has ceased. The aim of this study was to develop an in vitro methodology for determining the intrinsic susceptibility of L. pneumophila strains, collected from various nuclear power plant cooling circuits subjected to different treatment conditions. The methodology was developed by using an original approach based on response surface methodology (RSM) combined with a multifactorial experimental design. The susceptibility was evaluated by the Ct factor. The susceptibility of environmental strains varies widely and is, for some strains, greater than that of known tolerant species; however, strain susceptibility was not related to treatment conditions. Selection pressure induced by monochloramine use did not result in the selection of more tolerant Legionella strains and did not explain the detection of Legionella during treatment or the rapid re-colonisation of cooling circuits after disinfection has ceased.

  7. Presence of Legionella and Free-Living Amoebae in Composts and Bioaerosols from Composting Facilities

    PubMed Central

    Conza, Lisa; Pagani, Simona Casati; Gaia, Valeria

    2013-01-01

    Several species of Legionella cause Legionnaires’ disease (LD). Infection may occur through inhalation of Legionella or amoebal vesicles. The reservoirs of Legionella are water, soil, potting soil and compost. Some species of free-living amoebae (FLA) that are naturally present in water and soil were described as hosts for Legionella. This study aimed to understand whether or not the composting facilities could be sources of community-acquired Legionella infections after development of bioaerosols containing Legionella or FLA. We looked for the presence of Legionella (by co-culture) and FLA (by culture) in composts and bioaerosols collected at four composting facilities located in southern Switzerland. We investigated the association between the presence of Legionella and compost and air parameters and presence of FLA. Legionella spp. (including L. pneumophila) were detected in 69.3% (61/88) of the composts and FLA (mainly Acanthamoeba, Vermamoeba, Naegleria and Stenamoeba) in 92.0% (81/88). L. pneumophila and L. bozemanii were most frequently isolated. FLA as potential host for Legionella spp. were isolated from 40.9% (36/88) of the composts in all facilities. In Legionella-positive samples the temperature of compost was significantly lower (P = 0.012) than in Legionella-negative samples. Of 47 bioaerosol samples, 19.1% (9/47) were positive for FLA and 10.6% (5/47) for L. pneumophila. Composts (62.8%) were positive for Legionella and FLA contemporaneously, but both microorganisms were never detected simultaneously in bioaerosols. Compost can release bioaerosol containing FLA or Legionella and could represent a source of infection of community-acquired Legionella infections for workers and nearby residents. PMID:23844174

  8. Method modification of the Legipid® Legionella fast detection test kit.

    PubMed

    Albalat, Guillermo Rodríguez; Broch, Begoña Bedrina; Bono, Marisa Jiménez

    2014-01-01

    Legipid(®) Legionella Fast Detection is a test based on combined magnetic immunocapture and enzyme-immunoassay (CEIA) for the detection of Legionella in water. The test is based on the use of anti-Legionella antibodies immobilized on magnetic microspheres. Target microorganism is preconcentrated by filtration. Immunomagnetic analysis is applied on these preconcentrated water samples in a final test portion of 9 mL. The test kit was certified by the AOAC Research Institute as Performance Tested Method(SM) (PTM) No. 111101 in a PTM validation which certifies the performance claims of the test method in comparison to the ISO reference method 11731-1998 and the revision 11731-2004 "Water Quality: Detection and Enumeration of Legionella pneumophila" in potable water, industrial water, and waste water. The modification of this test kit has been approved. The modification includes increasing the target analyte from L. pneumophila to Legionella species and adding an optical reader to the test method. In this study, 71 strains of Legionella spp. other than L. pneumophila were tested to determine its reactivity with the kit based on CEIA. All the strains of Legionella spp. tested by the CEIA test were confirmed positive by reference standard method ISO 11731. This test (PTM 111101) has been modified to include a final optical reading. A methods comparison study was conducted to demonstrate the equivalence of this modification to the reference culture method. Two water matrixes were analyzed. Results show no statistically detectable difference between the test method and the reference culture method for the enumeration of Legionella spp. The relative level of detection was 93 CFU/volume examined (LOD50). For optical reading, the LOD was 40 CFU/volume examined and the LOQ was 60 CFU/volume examined. Results showed that the test Legipid Legionella Fast Detection is equivalent to the reference culture method for the enumeration of Legionella spp.

  9. Legionella Contamination in Hot Water of Italian Hotels

    PubMed Central

    Borella, Paola; Montagna, Maria Teresa; Stampi, Serena; Stancanelli, Giovanna; Romano-Spica, Vincenzo; Triassi, Maria; Marchesi, Isabella; Bargellini, Annalisa; Tatò, Daniela; Napoli, Christian; Zanetti, Franca; Leoni, Erica; Moro, Matteo; Scaltriti, Stefania; Ribera D'Alcalà, Gabriella; Santarpia, Rosalba; Boccia, Stefania

    2005-01-01

    A cross-sectional multicenter survey of Italian hotels was conducted to investigate Legionella spp. contamination of hot water. Chemical parameters (hardness, free chlorine concentration, and trace element concentrations), water systems, and building characteristics were evaluated to study risk factors for colonization. The hot water systems of Italian hotels were strongly colonized by Legionella; 75% of the buildings examined and 60% of the water samples were contaminated, mainly at levels of ≥103 CFU liter−1, and Legionella pneumophila was the most frequently isolated species (87%). L. pneumophila serogroup 1 was isolated from 45.8% of the contaminated sites and from 32.5% of the hotels examined. When a multivariate logistic model was used, only hotel age was associated with contamination, but the risk factors differed depending on the contaminating species and serogroup. Soft water with higher chlorine levels and higher temperatures were associated with L. pneumophila serogroup 1 colonization, whereas the opposite was observed for serogroups 2 to 14. In conclusion, Italian hotels, particularly those located in old buildings, represent a major source of risk for Legionnaires' disease due to the high frequency of Legionella contamination, high germ concentration, and major L. pneumophila serogroup 1 colonization. The possible role of chlorine in favoring the survival of Legionella species is discussed. PMID:16204491

  10. Legionella contamination in hot water of Italian hotels.

    PubMed

    Borella, Paola; Montagna, Maria Teresa; Stampi, Serena; Stancanelli, Giovanna; Romano-Spica, Vincenzo; Triassi, Maria; Marchesi, Isabella; Bargellini, Annalisa; Tatò, Daniela; Napoli, Christian; Zanetti, Franca; Leoni, Erica; Moro, Matteo; Scaltriti, Stefania; Ribera D'Alcalà, Gabriella; Santarpia, Rosalba; Boccia, Stefania

    2005-10-01

    A cross-sectional multicenter survey of Italian hotels was conducted to investigate Legionella spp. contamination of hot water. Chemical parameters (hardness, free chlorine concentration, and trace element concentrations), water systems, and building characteristics were evaluated to study risk factors for colonization. The hot water systems of Italian hotels were strongly colonized by Legionella; 75% of the buildings examined and 60% of the water samples were contaminated, mainly at levels of > or =10(3) CFU liter(-1), and Legionella pneumophila was the most frequently isolated species (87%). L. pneumophila serogroup 1 was isolated from 45.8% of the contaminated sites and from 32.5% of the hotels examined. When a multivariate logistic model was used, only hotel age was associated with contamination, but the risk factors differed depending on the contaminating species and serogroup. Soft water with higher chlorine levels and higher temperatures were associated with L. pneumophila serogroup 1 colonization, whereas the opposite was observed for serogroups 2 to 14. In conclusion, Italian hotels, particularly those located in old buildings, represent a major source of risk for Legionnaires' disease due to the high frequency of Legionella contamination, high germ concentration, and major L. pneumophila serogroup 1 colonization. The possible role of chlorine in favoring the survival of Legionella species is discussed.

  11. Minimum inhibitory concentration distribution in environmental Legionella spp. isolates.

    PubMed

    Sandalakis, Vassilios; Chochlakis, Dimosthenis; Goniotakis, Ioannis; Tselentis, Yannis; Psaroulaki, Anna

    2014-12-01

    In Greece standard tests are performed in the watering and cooling systems of hotels' units either as part of the surveillance scheme or following human infection. The purpose of this study was to establish the minimum inhibitory concentration (MIC) distributions of environmental Legionella isolates for six antimicrobials commonly used for the treatment of Legionella infections, by MIC-test methodology. Water samples were collected from 2004 to 2011 from 124 hotels from the four prefectures of Crete (Greece). Sixty-eight (68) Legionella isolates, comprising L. pneumophila serogroups 1, 2, 3, 5, 6, 8, 12, 13, 15, L. anisa, L. rubrilucens, L. maceachernii, L. quinlivanii, L. oakridgensis, and L. taurinensis, were included in the study. MIC-tests were performed on buffered charcoal yeast extract with α-ketoglutarate, L-cysteine, and ferric pyrophosphate. The MICs were read after 2 days of incubation at 36 ± 1 °C at 2.5% CO2. A large distribution in MICs was recorded for each species and each antibiotic tested. Rifampicin proved to be the most potent antibiotic regardless of the Legionella spp.; tetracycline appeared to have the least activity on our environmental isolates. The MIC-test approach is an easy, although not so cost-effective, way to determine MICs in Legionella spp. These data should be kept in mind especially since these Legionella species may cause human disease.

  12. Seasonal variation of Legionella in Taiwan's reservoir and its relationships with environmental factors.

    PubMed

    Kao, Po-Min; Hsu, Bing-Mu; Chang, Tien-Yu; Hsu, Tsui-Kang; Tzeng, Kai-Jiun; Huang, Yu-Li

    2015-04-01

    In this study, the presence of Legionella in major water reservoirs of Taiwan was examined with respect to seasonal variation, geographical variation, and water quality parameters using TaqMan real-time qPCR. Water samples were collected quarterly at 19 reservoirs in Taiwan between November 2012 and August 2013. The detection rate for Legionella was 35.5% (27/76), and Legionella was detected in all seasons. The Legionella concentration was relatively high in spring and summer, reaching 3.86 × 10(8) and 7.35 × 10(8) cells/L, respectively. By sampling the area, Legionella was detected at a higher proportion in reservoirs in the northern and southern areas, and the difference was consistent in all seasons. Significant association was found between detection of Legionella and various water quality parameters, including conductivity, chlorophyll a, and dissolved oxygen (Mann-Whitney U test, P < 0.05). Results of Spearman rank test showed negative correlation for Legionella detection with pH (P = 0.030, R = -0.497) and dissolved oxygen (P = 0.007, R = -0.596) in fall and positive correlation with Carlson's trophic state index (P = 0.049, R = 0.457) in spring. The identified species included Legionella pneumophila and Legionella drancourtii. The detection of Legionella in reservoirs was indicative of a potential public health risk and should be further evaluated.

  13. Genome analysis of Legionella pneumophila strains using a mixed-genome microarray.

    PubMed

    Euser, Sjoerd M; Nagelkerke, Nico J; Schuren, Frank; Jansen, Ruud; Den Boer, Jeroen W

    2012-01-01

    Legionella, the causative agent for Legionnaires' disease, is ubiquitous in both natural and man-made aquatic environments. The distribution of Legionella genotypes within clinical strains is significantly different from that found in environmental strains. Developing novel genotypic methods that offer the ability to distinguish clinical from environmental strains could help to focus on more relevant (virulent) Legionella species in control efforts. Mixed-genome microarray data can be used to perform a comparative-genome analysis of strain collections, and advanced statistical approaches, such as the Random Forest algorithm are available to process these data. Microarray analysis was performed on a collection of 222 Legionella pneumophila strains, which included patient-derived strains from notified cases in The Netherlands in the period 2002-2006 and the environmental strains that were collected during the source investigation for those patients within the Dutch National Legionella Outbreak Detection Programme. The Random Forest algorithm combined with a logistic regression model was used to select predictive markers and to construct a predictive model that could discriminate between strains from different origin: clinical or environmental. Four genetic markers were selected that correctly predicted 96% of the clinical strains and 66% of the environmental strains collected within the Dutch National Legionella Outbreak Detection Programme. The Random Forest algorithm is well suited for the development of prediction models that use mixed-genome microarray data to discriminate between Legionella strains from different origin. The identification of these predictive genetic markers could offer the possibility to identify virulence factors within the Legionella genome, which in the future may be implemented in the daily practice of controlling Legionella in the public health environment.

  14. [Activity of macrolides and fluoroquinolones against intracellular Legionella pneumophila].

    PubMed

    Yu, Ling-ling; Hu, Bi-jie; Huang, Sheng-lei; Zhou, Zhao-yan; Tao, Li-li

    2011-06-01

    To evaluate the activity of macrolides and fluoroquinolones against Legionella pneumophila by intracellular susceptibility testing. Minimum inhibitory concentration (MIC) was determined by standard agar dilution test according to the CLSI. For intracellular assays, legionella pneumonia was used to infect human monocytic cell line THP-1. Erythromycin, azithromycin, levofloxacin and moxifloxacin at 1 × MIC, 4 × MIC, 8 × MIC were added following phagocytosis. Number of viable bacteria was enumerated at 24 h on BCYE (buffered charcoal yeast extract) agar in duplicates using standard plate count method. The result was expressed as percentage inhibition. Mann-Whitney U test was used to determine the significant differences in mean percentage inhibition between agents. Percentage inhibition at 24 h were as follows: Erythromycin 1 × MIC (50.18 ± 27.29)%, 4 × MIC (79.48 ± 20.08)%, 8 × MIC (91.46 ± 8.70)%; Azithromycin 1 × MIC (66.77 ± 26.18)%, 4 × MIC (91.73 ± 8.72)%, 8 × MIC (97.10 ± 3.37)%; Levofloxacin 1 × MIC (99.84 ± 0.25)%, 4 × MIC (99.99 ± 0.02)%, 8 × MIC (99.99 ± 0.01)%; Moxifloxacin 1 × MIC (99.90 ± 0.10)%, 4 × MIC (99.99 ± 0.03)%, 8 × MIC (99.99 ± 0.03)%. The fluoroquinolones showed greater inhibitory activity than macrolides against legionella pneumophila(u = 1.0, 2.0, 5.0, P < 0.05). Levofloxacin and moxifloxacin had the same intracellular activity against legionella pneumophila (u = 190, 183, 217, P > 0.05). Azithromycin was more effective than erythromycin in inhibiting intracellular legionella pneumophila (u = 132, 125, 128, P < 0.05). The fluoroquinolones were more active than macrolides against legionella pneumophila. The intracellular activity of levofloxacin against legionella pneumophila appeared to be similar to moxifloxacin. Azithromycin was demonstrated to have superior activity against legionella pneumophila compared with erythromycin.

  15. Legionella spp. in UK composts--a potential public health issue?

    PubMed

    Currie, S L; Beattie, T K; Knapp, C W; Lindsay, D S J

    2014-04-01

    Over the past 5 years, a number of cases of legionellosis in Scotland have been associated with compost use; however, studies investigating sources of infection other than water systems remain limited. This study delivers the first comprehensive survey of composts commonly available in the UK for the presence of Legionella species. Twenty-two store-bought composts, one green-waste compost and one home-made compost were tested for Legionella by culture methods on BCYE-α medium, and the findings were confirmed by macrophage infectivity potentiator (mip) speciation. Twenty-two of the samples were retested after an enrichment period of 8 weeks. In total, 15 of 24 composts tested positive for Legionella species, a higher level of contamination than previously seen in Europe. Two isolates of Legionella pneumophila were identified, and Legionella longbeachae serogroup 1 was found to be one of the most commonly isolated species. L. longbeachae infection would not be detected by routine Legionella urinary antigen assay, so such testing should not be used as the sole diagnostic technique in atypical pneumonia cases, particularly where there is an association with compost use. The occurrence of Legionella in over half of the samples tested indicates that compost could pose a public health risk. The addition of general hygiene warnings to compost packages may be beneficial in protecting public health. © 2013 The Authors Clinical Microbiology and Infection © 2013 European Society of Clinical Microbiology and Infectious Diseases.

  16. [A Case of Severe Legionella longbeachae Pneumonia and Usefulness of LAMP Assay].

    PubMed

    Matsushita, Kumiko; Hijikuro, Kohei; Arita, Shohei; Kaneko, Yu; Isozaki, Masahiro

    2017-08-15

    Urinary antigen test is frequently used as a routine laboratory test for early diagnosis of Legionella infection , which is especially suitable for ordinary Legionella pneumophila serogroup 1, but not for other types of Legionella . We report a case of severe pneumonia caused by Legionella longbeachae , where a method of loop-mediated isothermal amplification (LAMP) assay contributed an important role for the early detection. This case involved an 83-year-old man who developed fever, dyspnea, and productive cough. Since the medication of prescribed ceftriaxone had not been effective, he visited the emergency room of our hospital, where an X-ray revealed a severe pneumonia harboring a consolidation with air bronchogram in his right lower lung. His sputum and urine were subjected to the routine bacterial culture or the urinary antigen test for Legionella , which initially brought negative results. However, a positive result of LAMP assay enabled early diagnosis of Legionella pneumonia . Later, the bacterial cultures of sputum made some progress and 16S rRNA sequencing provided a proof of L. longbeachae . This LAMP assay may bring a benefit for the patients with Legionella pneumonia by enabling early detection of not only specific L. pneumophila serogroup 1, but also of the other Legionella species.

  17. Distribution of Legionella and bacterial community composition among regionally diverse US cooling towers

    PubMed Central

    Llewellyn, Anna C.; Lucas, Claressa E.; Roberts, Sarah E.; Brown, Ellen W.; Nayak, Bina S.; Winchell, Jonas M.

    2017-01-01

    Cooling towers (CTs) are a leading source of outbreaks of Legionnaires’ disease (LD), a severe form of pneumonia caused by inhalation of aerosols containing Legionella bacteria. Accordingly, proper maintenance of CTs is vital for the prevention of LD. The aim of this study was to determine the distribution of Legionella in a subset of regionally diverse US CTs and characterize the associated microbial communities. Between July and September of 2016, we obtained aliquots from water samples collected for routine Legionella testing from 196 CTs located in eight of the nine continental US climate regions. After screening for Legionella by PCR, positive samples were cultured and the resulting Legionella isolates were further characterized. Overall, 84% (164) were PCR-positive, including samples from every region studied. Of the PCR-positive samples, Legionella spp were isolated from 47% (78), L. pneumophila was isolated from 32% (53), and L. pneumophila serogroup 1 (Lp1) was isolated from 24% (40). Overall, 144 unique Legionella isolates were identified; 53% (76) of these were Legionella pneumophila. Of the 76 L. pneumophila isolates, 51% (39) were Lp1. Legionella were isolated from CTs in seven of the eight US regions examined. 16S rRNA amplicon sequencing was used to compare the bacterial communities of CT waters with and without detectable Legionella as well as the microbiomes of waters from different climate regions. Interestingly, the microbial communities were homogenous across climate regions. When a subset of seven CTs sampled in April and July were compared, there was no association with changes in corresponding CT microbiomes over time in the samples that became culture-positive for Legionella. Legionella species and Lp1 were detected frequently among the samples examined in this first large-scale study of Legionella in US CTs. Our findings highlight that, under the right conditions, there is the potential for CT-related LD outbreaks to occur throughout the

  18. Distribution of Legionella and bacterial community composition among regionally diverse US cooling towers.

    PubMed

    Llewellyn, Anna C; Lucas, Claressa E; Roberts, Sarah E; Brown, Ellen W; Nayak, Bina S; Raphael, Brian H; Winchell, Jonas M

    2017-01-01

    Cooling towers (CTs) are a leading source of outbreaks of Legionnaires' disease (LD), a severe form of pneumonia caused by inhalation of aerosols containing Legionella bacteria. Accordingly, proper maintenance of CTs is vital for the prevention of LD. The aim of this study was to determine the distribution of Legionella in a subset of regionally diverse US CTs and characterize the associated microbial communities. Between July and September of 2016, we obtained aliquots from water samples collected for routine Legionella testing from 196 CTs located in eight of the nine continental US climate regions. After screening for Legionella by PCR, positive samples were cultured and the resulting Legionella isolates were further characterized. Overall, 84% (164) were PCR-positive, including samples from every region studied. Of the PCR-positive samples, Legionella spp were isolated from 47% (78), L. pneumophila was isolated from 32% (53), and L. pneumophila serogroup 1 (Lp1) was isolated from 24% (40). Overall, 144 unique Legionella isolates were identified; 53% (76) of these were Legionella pneumophila. Of the 76 L. pneumophila isolates, 51% (39) were Lp1. Legionella were isolated from CTs in seven of the eight US regions examined. 16S rRNA amplicon sequencing was used to compare the bacterial communities of CT waters with and without detectable Legionella as well as the microbiomes of waters from different climate regions. Interestingly, the microbial communities were homogenous across climate regions. When a subset of seven CTs sampled in April and July were compared, there was no association with changes in corresponding CT microbiomes over time in the samples that became culture-positive for Legionella. Legionella species and Lp1 were detected frequently among the samples examined in this first large-scale study of Legionella in US CTs. Our findings highlight that, under the right conditions, there is the potential for CT-related LD outbreaks to occur throughout the US.

  19. Legionella oakridgensis: unusual new species isolated from cooling tower water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Orrison, L.H.; Cherry, W.B.; Tyndall, R.L.

    1983-02-01

    A new species of Legionella represented by 10 strains isolated from industrial cooling towers is described. Legionella oakridgensis differed genetically from the other seven species of Legionella in DNA hybridization studies and differed serologically in direct fluorescent-antibody tests. The new species, unlike all other species except L. jordanis, did not require added L-cysteine for growth in serial transfer on charcoal-yeast extract agar. L. oakridgensis, as well as three other species tested, required L-cysteine for primary isolation from animal tissues. L. oakridgensis was the only species of Legionella that failed to produce alkaline phosphatase at pH 8.5. In all other respects,more » it resembled other species of Legionella, including having a high content of branched-chain cellular fatty acids and being pathogenic for guinea pigs. These bacteria have not yet been associated with human disease, but they are potential causes of legionellosis.« less

  20. Spatial arrangement of legionella colonies in intact biofilms from a model cooling water system.

    PubMed

    Taylor, Michael; Ross, Kirstin; Bentham, Richard

    2013-01-01

    There is disagreement among microbiologists about whether Legionella requires a protozoan host in order to replicate. This research sought to determine where in biofilm Legionellae are found and whether all biofilm associated Legionella would be located within protozoan hosts. While it is accepted that Legionella colonizes biofilm, its life cycle and nutritional fastidiousness suggest that Legionella employs multiple survival strategies to persist within microbial systems. Fluorescent in situ hybridization (FISH) and confocal laser scanning microscopy (CLSM) demonstrated an undulating biofilm surface architecture and a roughly homogenous distribution of heterotrophic bacteria with clusters of protozoa. Legionella displayed 3 distinct spatial arrangements either contained within or directly associated with protozoa, or dispersed in loosely associated clusters or in tightly packed aggregations of cells forming dense colonial clusters. The formation of discreet clusters of tightly packed Legionella suggests that colony formation is influenced by specific environmental conditions allowing for limited extracellular replication. This work represents the first time that an environmentally representative, multispecies biofilm containing Legionella has been fluorescently tagged and Legionella colony morphology noted within a complex microbial system.

  1. Routine sampling and the control of Legionella spp. in cooling tower water systems.

    PubMed

    Bentham, R H

    2000-10-01

    Cooling water samples from 31 cooling tower systems were cultured for Legionella over a 16-week summer period. The selected systems were known to be colonized by Legionella. Mean Legionella counts and standard deviations were calculated and time series correlograms prepared for each system. The standard deviations of Legionella counts in all the systems were very large, indicating great variability in the systems over the time period. Time series analyses demonstrated that in the majority of cases there was no significant relationship between the Legionella counts in the cooling tower at time of collection and the culture result once it was available. In the majority of systems (25/28), culture results from Legionella samples taken from the same systems 2 weeks apart were not statistically related. The data suggest that determinations of health risks from cooling towers cannot be reliably based upon single or infrequent Legionella tests.

  2. Native Valve Endocarditis Due to a Novel Strain of Legionella

    PubMed Central

    Pearce, Meghan M.; Theodoropoulos, Nicole; Noskin, Gary A.; Flaherty, John P.; Stemper, Mary E.; Aspeslet, Teresa; Cianciotto, Nicholas P.; Reed, Kurt D.

    2011-01-01

    Legionellae are Gram-negative bacteria which are capable of causing disease, most commonly in the form of pneumonia. We describe a case of native valve endocarditis caused by a Legionella strain which by genotypic (16S rRNA and mip gene sequencing) and phenotypic analyses is unlike previously described strains of Legionella. PMID:21795511

  3. Occurrence of Legionella in wastewater treatment plants linked to wastewater characteristics.

    PubMed

    Caicedo, C; Beutel, S; Scheper, T; Rosenwinkel, K H; Nogueira, R

    2016-08-01

    In recent years, the occurrence of Legionella in wastewater treatment plants (WWTP) has often been reported. However, until now there is limited knowledge about the factors that promote Legionella's growth in such systems. The aim of this study was to investigate the chemical wastewater parameters that might be correlated to the concentration of Legionella spp. in WWTP receiving industrial effluents. For this purpose, samples were collected at different processes in three WWTP. In 100 % of the samples taken from the activated sludge tanks Legionella spp. were detected at varying concentrations (4.8 to 5.6 log GU/mL) by the quantitative real-time polymerase chain reaction method, but not by the culture method. Statistical analysis with various parameters yielded positive correlations of Legionella spp. concentration with particulate chemical oxygen demand, Kjeldahl nitrogen and protein concentration. Amino acids were quantified in wastewater and activated sludge samples at concentrations that may not support the growth of Legionella, suggesting that in activated sludge tanks this bacterium multiplied in protozoan hosts.

  4. Legionella busanensis sp. nov., isolated from cooling tower water in Korea.

    PubMed

    Park, Mi-Yeoun; Ko, Kwan Soo; Lee, Hae Kyung; Park, Man-Suk; Kook, Yoon-Hoh

    2003-01-01

    Three Legionella-like micro-organisms, isolated from cooling tower water of a building in Busan, Korea, were characterized by a variety of biochemical and molecular phylogenetic tests. Analyses of whole-cell fatty acids and results of biochemical tests revealed that these three isolates are distinct from previously described Legionella species. Furthermore, results of comparative analyses of 16S rDNA (1476-1488 bp), mip (408 bp) and rpoB (300 bp) sequences also confirmed that these strains represent a novel species within the genus Legionella. The 16S rDNA sequences of the three Korean isolates had similarities of less than 95.8% to other Legionella species. Phylogenetic trees formed by analysis of the 16S rRNA, rpoB and mip genes revealed that the isolates formed a distinct cluster within the genus Legionella. Based on the evaluated phenotypic and phylogenetic characteristics, it is proposed that these Korean isolates from water be classified as a novel species, Legionella busanensis sp. nov.; the type strain is strain K9951T (=KCTC 12084T =ATCC BAA-518T).

  5. Legionella pneumophila: From potable water to treated greywater; quantification and removal during treatment.

    PubMed

    Blanky, Marina; Rodríguez-Martínez, Sara; Halpern, Malka; Friedler, Eran

    2015-11-15

    Greywater is an alternative water source that can help alleviate stress on depleted water resources. The main options for greywater reuse are toilet flushing and garden irrigation, both producing aerosols. For that reason transmission of inhalable pathogens like Legionella present a potential risk. To improve the understanding about Legionella in greywater, we traced the pathogen seasonally from the potable water system to the final steps of the greywater treatment in four houses in northern Israel. Physicochemical and microbiological parameters were analyzed in order to assess background greywater quality and to establish possible associations with Legionella. The mean concentrations of Legionella pneumophila isolated from the potable water system were 6.4×10(2) and 5.9×10(3) cfu/l in cold and hot water respectively. By amending the ISO protocol for Legionella isolation from drinking water, we succeeded in quantifying Legionella in greywater. The mean Legionella concentrations that were found in raw, treated and treated chlorinated greywater were 1.2×10(5), 2.4×10(4) and 5.7×10(3) cfu/l respectively. While Legionella counts in potable water presented a seasonal pattern with high concentrations in summer, its counts in greywater presented an almost inversed pattern. Greywater treatment resulted in 95% decrease in Legionella counts. No significant difference was found between Legionella concentrations in potable water and the treated chlorinated greywater. These findings indicate that regarding Legionella, reusing treated chlorinated greywater would exhibit a risk that is very similar to the risk associated with using potable water for the same non-potable uses. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. SURVEY OF GROUND, SURFACE, AND POTABLE WATERS FOR THE PRESENCE OF LEGIONELLA SPECIES BY ENVIROAMP PCR LEGIONELLA KIT, CULTURE, AND IMMUNOFLUORESCENT STAINING

    EPA Science Inventory

    A total of 116 samples from numerous aquatic sources including water from faucets, showerheads, dental units, fire sprinklers, and surface waters were examined for the presence of Legionella by the EnviroAmp Legionella PCR kit, culture on BCYEx, or direct fluorescent antibody (DF...

  7. Strategies for the reduction of Legionella in biological treatment systems.

    PubMed

    Nogueira, R; Utecht, K-U; Exner, M; Verstraete, W; Rosenwinkel, K-H

    A community-wide outbreak of Legionnaire's disease occurred in Warstein, Germany, in August 2013. The epidemic strain, Legionella pneumophila Serogruppe 1, was isolated from an industrial wastewater stream entering the municipal wastewater treatment plant (WWTP) in Wartein, the WWTP itself, the river Wäster and air/water samples from an industrial cooling system 3 km downstream of the WWTP. The present study investigated the effect of physical-chemical disinfection methods on the reduction of the concentration of Legionella in the biological treatment and in the treated effluent entering the river Wäster. Additionally, to gain insight into the factors that promote the growth of Legionella in biological systems, growth experiments were made with different substrates and temperatures. The dosage rates of silver micro-particles, hydrogen peroxide, chlorine dioxide and ozone and pH stress to the activated sludge were not able to decrease the number of culturable Legionella spp. in the effluent. Nevertheless, the UV treatment of secondary treated effluent reduced Legionella spp. on average by 1.6-3.4 log units. Laboratory-scale experiments and full-scale measurements suggested that the aerobic treatment of warm wastewater (30-35 °C) rich in organic nitrogen (protein) is a possible source of Legionella infection.

  8. Legionella contamination in the water system of hospital dental settings.

    PubMed

    Veronesi, Licia; Capobianco, Emanuela; Affanni, Paola; Pizzi, Silvia; Vitali, Pietro; Tanzi, Maria Luisa

    2007-08-01

    Among hospital facilities the dental unit is an environment that is at major risk of Legionella due to equipment such as the air/water syringe, the turbine, the micromotor and the scaler which generate potentially harmful aerosols that may to be a source of exposure to Legionella spp. particularly in immunodeficient patients, and those affected by chronic diseases, and also in dental personnel. Therefore, an examination of the extent of Legionella spp. contamination in the dental chairs waterlines and the incoming water supply of some public dental units is the subject of the present study. From February 2002 to March 2004, a total of 208 water samples were collected: 160 samples from the water supply of 4 dental chair and 48 samples from the cold incoming tap water of 2 units. Legionella spp. was detected in 46 samples (22.1% ): 19 of them (41.3% of Legionella spp.; 9.1% of the total) were Legionella pneumophila; Pseudomonas aeruginosa was detected in 86 samples (41.4%) and both microorganisms were detected in 2 samples (0.96%). Our results show a microbiological condition in dental settings, that is not at all satisfactory due to the presence of Legionella in concentrations that are considered to be a health hazard (> or = 10(3)) in certain cases. Given the extent of the health risk in these surroundings, the difficulty in its assessment, and also considering the wide diffusion of general dental care, our investigation has confirmed the need to regularly monitor the microbiological condition of water in dental units.

  9. Existence and control of Legionella bacteria in building water systems: A review.

    PubMed

    Springston, John P; Yocavitch, Liana

    2017-02-01

    Legionellae are waterborne bacteria which are capable of causing potentially fatal Legionnaires' disease (LD), as well as Pontiac Fever. Public concern about Legionella exploded following the 1976 outbreak at the American Legion conference in Philadelphia, where 221 attendees contracted pneumonia and 34 died. Since that time, a variety of different control methods and strategies have been developed and implemented in an effort to eradicate Legionella from building water systems. Despite these efforts, the incidence of LD has been steadily increasing in the U.S. for more than a decade. Public health and occupational hygiene professionals have maintained an active debate regarding best practices for management and control of Legionella. Professional opinion remains divided with respect to the relative merits of performing routine sampling for Legionella, vs. the passive, reactive approach that has been largely embraced by public health officials and facility owners. Given the potential risks and ramifications associated with waiting to assess systems for Legionella until after disease has been identified and confirmed, a proactive approach of periodic testing for Legionella, along with proper water treatment, is the best approach to avoiding large-scale disease outbreaks.

  10. Genetic speciation of environmental Legionella isolates in Thailand.

    PubMed

    Paveenkittiporn, Wantana; Dejsirilert, Surang; Kalambaheti, Thareerat

    2012-10-01

    Legionella-like organisms were isolated during 2003-2007 from various water resources by culturing on selective media of Wadowsky-Yee-Okuda agar. The 256 isolates were identified as belonging to the Legionella genus based on detection of 108 bp PCR product of the 5S rRNA gene, while the inclusion as Legionella pneumophila were confirmed by PCR detection of a specific mip gene region of 168 bp. The 50 isolates, identified as non-pneumophila, were then subjected to DNA tree analysis, based on mip gene of ~650 bp and rnpB genes product ranged from 304 to 354 bp. Phylogenetic tree was constructed to predict their species in relative to the available database. The isolates of which their speciation, based on those two genes were inconclusive, were then investigated for the almost full-length of 16S rRNA sequences. The isolates were assigned as 16 known Legionella species, and proposed seven novel species based on their unique 16S rRNA sequence. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Effects of Disinfection on Legionella spp., Eukarya, and Biofilms in a Hot Water System

    PubMed Central

    Moletta-Denat, Marina; Frère, Jacques; Onillon, Séverine; Trouilhé, Marie-Cécile; Robine, Enric

    2012-01-01

    Legionella species are frequently detected in hot water systems, attached to the surface as a biofilm. In this work, the dynamics of Legionella spp. and diverse bacteria and eukarya associated together in the biofilm, coming from a pilot scale 1 system simulating a real hot water system, were investigated throughout 6 months after two successive heat shock treatments followed by three successive chemical treatments. Community structure was assessed by a fingerprint technique, single-strand conformation polymorphism (SSCP). In addition, the diversity and dynamics of Legionella and eukarya were investigated by small-subunit (SSU) ribosomal cloning and sequencing. Our results showed that pathogenic Legionella species remained after the heat shock and chemical treatments (Legionella pneumophila and Legionella anisa, respectively). The biofilm was not removed, and the bacterial community structure was transitorily affected by the treatments. Moreover, several amoebae had been detected in the biofilm before treatments (Thecamoebae sp., Vannella sp., and Hartmanella vermiformis) and after the first heat shock treatment, but only H. vermiformis remained. However, another protozoan affiliated with Alveolata, which is known as a host cell for Legionella, dominated the eukaryal species after the second heat shock and chemical treatment tests. Therefore, effective Legionella disinfection may be dependent on the elimination of these important microbial components. We suggest that eradicating Legionella in hot water networks requires better study of bacterial and eukaryal species associated with Legionella in biofilms. PMID:22820326

  12. The antibacterial activity of compounds isolated from oakmoss against Legionella pneumophila and other Legionella spp.

    PubMed

    Nomura, Harue; Isshiki, Yasunori; Sakuda, Keisuke; Sakuma, Katsuya; Kondo, Seiichi

    2012-01-01

    Oakmoss is a natural fragrance ingredient exhibiting highly specific, potent antibacterial activity against Legionella pneumophila, a causative agent of severe water-bone pneumonia. In the present study, the antibacterial activity of individual compounds isolated from oakmoss was investigated against L. pneumophila and other Legionella spp. A total of 18 known compounds and two minor novel compounds (i.e., 3-methoxy-5-methylphenyl-2,4-dihydroxy-6-methylbenzoate (compound 9) and 8-(2,4-dihydroxy-6-(2-oxoheptyl)-phenoxy)-6-hydroxy-3-pentyl-1H-isochromen-1-one (compound 20)) were purified from oakmoss. The minimum inhibitory concentrations (MICs) against clinical and environmental isolates of L. pneumophila, L. bozemanii, L. micdadei, L. longbeachae, and L. dumoffii for 11 of the 20 compounds were less than 100 µg/mL (range 0.8-64.0 µg/mL). Novel compounds 9 and 20 exhibited potent antibacterial activity against L. pneumophila strains (MIC ranges of 1.3-8.0 µg/mL and 3.3-13.3 µg/mL, respectively) and also against four other Legionella species (MIC ranges of 0.8-8.0 µg/mL and 3.3-21.3 µg/mL, respectively). Time-kill assays indicated that compounds 9 and 20 kill bacteria at a concentration equivalent to 2×MIC after 1 h and 6 h co-incubations, respectively. While oakmoss and the purified components exhibited antibacterial activity against Legionella spp., they were not active against other Gram-negative and -positive bacteria such as Escherichia coli, Pseudomonas aeruginosa, Bacillus subtilis and Staphylococcus aureus.

  13. High prevalence of Legionella in non-passenger merchant vessels.

    PubMed

    Collins, S L; Stevenson, D; Mentasti, M; Shaw, A; Johnson, A; Crossley, L; Willis, C

    2017-03-01

    There is a paucity of information on the risk from potable water in non-passenger merchant vessels (NPMVs) particularly with regard to Legionella and other bacteria. This retrospective study examined water samples from 550 NPMVs docked in eight UK ports. A total of 1027 samples from 412 NPMVs were examined for total aerobic colony counts (ACC), coliforms, Escherichia coli and enterococci; 41% of samples yielded ACC above the action level (>1 × 103 c.f.u./ml) and 4·5% contained actionable levels (>1 c.f.u./100 ml) of faecal indicator bacteria. Eight hundred and three samples from 360 NPMVs were cultured specifically for Legionella and 58% of vessels proved positive for these organisms with 27% of samples showing levels greater than the UK upper action limit of 1 × 103 c.f.u./l. Cabin showers (49%) and hospital shower (45%) were frequently positive. A subset of 106 samples was analysed by quantitative polymerase chain reaction for Legionella and identified a further 11 Legionella-positive NPMVs, returning a negative predictive value of 100%. There was no correlation between NPMV age or size and any microbial parameters (P > 0·05). Legionella pneumophila serogroup 1 was isolated from 46% of NPMVs and sequence-based typing of 17 isolates revealed four sequence types (STs) previously associated with human disease. These data raise significant concerns regarding the management of microbial and Legionella risks on board NPMVs and suggest that better guidance and compliance are required to improve control.

  14. Legionella detection by culture and qPCR: Comparing apples and oranges.

    PubMed

    Whiley, Harriet; Taylor, Michael

    2016-01-01

    Legionella spp. are the causative agent of Legionnaire's disease and an opportunistic pathogen of significant public health concern. Identification and quantification from environmental sources is crucial for identifying outbreak origins and providing sufficient information for risk assessment and disease prevention. Currently there are a range of methods for Legionella spp. quantification from environmental sources, but the two most widely used and accepted are culture and real-time polymerase chain reaction (qPCR). This paper provides a review of these two methods and outlines their advantages and limitations. Studies from the last 10 years which have concurrently used culture and qPCR to quantify Legionella spp. from environmental sources have been compiled. 26/28 studies detected Legionella at a higher rate using qPCR compared to culture, whilst only one study detected equivalent levels of Legionella spp. using both qPCR and culture. Aggregating the environmental samples from all 28 studies, 2856/3967 (72%) tested positive for the presence of Legionella spp. using qPCR and 1331/3967 (34%) using culture. The lack of correlation between methods highlights the need to develop an acceptable standardized method for quantification that is sufficient for risk assessment and management of this human pathogen.

  15. Anti-Legionella activity of staphylococcal hemolytic peptides.

    PubMed

    Marchand, A; Verdon, J; Lacombe, C; Crapart, S; Héchard, Y; Berjeaud, J M

    2011-05-01

    A collection of various Staphylococci was screened for their anti-Legionella activity. Nine of the tested strains were found to secrete anti-Legionella compounds. The culture supernatants of the strains, described in the literature to produce hemolytic peptides, were successfully submitted to a two step purification process. All the purified compounds, except one, corresponded to previously described hemolytic peptides and were not known for their anti-Legionella activity. By comparison of the minimal inhibitory concentrations, minimal permeabilization concentrations, decrease in the number of cultivable bacteria, hemolytic activity and selectivity, the purified peptides could be separated in two groups. First group, with warnericin RK as a leader, corresponds to the more hemolytic and bactericidal peptides. The peptides of the second group, represented by the PSMα from Staphylococcus epidermidis, appeared bacteriostatic and poorly hemolytic. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. An in-premise model for Legionella exposure during showering events.

    PubMed

    Schoen, Mary E; Ashbolt, Nicholas J

    2011-11-15

    An exposure model was constructed to predict the critical Legionella densities in an engineered water system that result in infection from inhalation of aerosols containing the pathogen while showering. The model predicted the Legionella densities in the shower air, water and in-premise plumbing biofilm that might result in a deposited dose of Legionella in the alveolar region of the lungs associated with infection for a routine showering event. Processes modeled included the detachment of biofilm-associated Legionella from the in-premise plumbing biofilm during a showering event, the partitioning of the pathogen from the shower water to the air, and the inhalation and deposition of particles in the lungs. The range of predicted critical Legionella densities in the air and water was compared to the available literature. The predictions were generally within the limited set of observations for air and water, with the exception of Legionella density within in-premise plumbing biofilms, for which there remains a lack of observations for comparison. Sensitivity analysis of the predicted results to possible changes in the uncertain input parameters identified the target deposited dose associated with infections, the pathogen air-water partitioning coefficient, and the quantity of detached biofilm from in-premise pluming surfaces as important parameters for additional data collection. In addition, the critical density of free-living protozoan hosts in the biofilm required to propagate the infectious Legionella was estimated. Together, this evidence can help to identify critical conditions that might lead to infection derived from pathogens within the biofilms of any plumbing system from which humans may be exposed to aerosols. Published by Elsevier Ltd.

  17. Legionella pollution in cooling tower water of air-conditioning systems in Shanghai, China.

    PubMed

    Lin, H; Xu, B; Chen, Y; Wang, W

    2009-02-01

    To determine Legionella pollution prevalence, describe the amount of Legionellae with respect to temperature in Shanghai cooling tower water (CTWs) in various types of public sites. Six urban districts were selected as the study fields, adopting multiple-phase sampling methods. Routine culture was used to identify Legionellae. Of the samples, 58.9% (189/321) were observed to be positive, 19.9% were isolated over 100 CFU ml(-1). Legionella pneumophila serogroup 1 was the most frequently isolated species (155/189, 82.0%), followed by Leg. micdadei that was at the second place (44/189, 23.3%). The mean CFU ml(-1) of Legionellae in CTWs reached its peak from July to September. Over all 15.4% of the samples exceeding 100 CFU ml(-1) were observed in a hospital setting. The prevalence of Legionella pollution in CTWs, especially in CTWs of subway stations and hospitals, is worrying, and the positive rate and CFU ml(-1) of Legionellae in CTWs have a close relationship with air temperature. The study demonstrates pollution prevalence rates in different types of sites and various seasons, and provides a proportion of different serogroups of Legionellae. It illuminates an urgent need for dealing with the potential risk of legionellosis in Shanghai, through improved control and prevention strategies.

  18. Monochloramine use for prevention of Legionella in hospital water systems.

    PubMed

    Kandiah, Sheetal; Yassin, Mohamed H; Stout, Janet

    2013-06-01

    Eradication of Legionella species from water distribution systems especially in hospital settings has proven to be challenging. Legionella species causes Legionnaire's disease that is a potentially fatal respiratory disease often acquired through the aerosolization of contaminated water. Monochloramine has been used successfully in the municipal water systems to eradicate Legionella and there is currently limited data to support its use in the hospital setting. This technology appears to be affordable, safe and effective at penetrating biofilm in water distribution systems.

  19. Identification of Legionella Species by Random Amplified Polymorphic DNA Profiles

    PubMed Central

    Lo Presti, François; Riffard, Serge; Vandenesch, François; Etienne, Jerome

    1998-01-01

    Random amplified polymorphic DNA (RAPD) was used for the identification of Legionella species. Primer SK2 (5′-CGGCGGCGGCGG-3′) and standardized RAPD conditions gave the technique a reproducibility of 93 to 100%, depending on the species tested. Species-specific patterns corresponding to the 42 Legionella species were consequently defined by this method; the patterns were dependent on the recognition of a core of common bands for each species. This specificity was demonstrated by testing 65 type strains and 265 environmental and clinical isolates. No serogroup-specific profiles were obtained. A number of unidentified Legionella isolates potentially corresponding to new species were clustered in four groups. RAPD analysis appears to be a rapid and reproducible technique for identification of Legionella isolates to the species level without further restriction or hybridization. PMID:9774564

  20. Legionella pneumophila lung abscess associated with immune suppression.

    PubMed

    Guy, S D; Worth, L J; Thursky, K A; Francis, P A; Slavin, M A

    2011-10-01

    Legionella species are a common cause of community-acquired pneumonia, infrequently complicated by cavitary disease. We describe Legionella pneumophila pneumonia and abscess formation in an immunosuppressed patient receiving corticosteroid therapy for metastatic breast carcinoma. The predisposing role of corticosteroids is discussed and the management of this complication is reviewed. © 2011 The Authors. Internal Medicine Journal © 2011 Royal Australasian College of Physicians.

  1. Detection of Legionella pneumophila by real-time PCR for the mip gene.

    PubMed

    Wilson, Deborah A; Yen-Lieberman, Belinda; Reischl, Udo; Gordon, Steve M; Procop, Gary W

    2003-07-01

    A real-time PCR assay for the mip gene of Legionella pneumophila was tested with 27 isolates of L. pneumophila, 20 isolates of 14 other Legionella species, and 103 non-Legionella bacteria. Eight culture-positive and 40 culture-negative clinical specimens were tested. This assay was 100% sensitive and 100% specific for L. pneumophila.

  2. Human Anti-Lipopolysaccharid (LPS) antibodies against Legionella with high species specificity.

    PubMed

    Kuhn, Philipp; Thiem, Stefanie; Steinert, Michael; Purvis, Duncan; Lugmayr, Veronika; Treutlein, Ulrich; Plobner, Lutz; Leiser, Robert-Matthias; Hust, Michael; Dübel, Stefan

    2017-07-19

    Legionella are Gram-negative bacteria that are ubiquitously present in natural and man-made water reservoirs. When humans inhale aerosolized water contaminated with Legionella, alveolar macrophages can be infected, which may lead to a life-threatening pneumonia called Legionnaires' disease. Due to the universal distribution of Legionella in water and their potential threat to human health, the Legionella concentration in water for human use must be strictly monitored, which is difficult since the standard detection still relies on lengthy cultivation and analysis of bacterial morphology. In this study, an antibody against L. pneumophila has been generated from the naïve human HAL antibody libraries by phage-display for the first time. The panning was performed on whole bacterial cells in order to select antibodies that bind specifically to the cell surface of untreated Legionella. The bacterial cell wall component lipopolysaccharide (LPS) was identified as the target structure. Specific binding to the important pathogenic L. pneumophila strains Corby, Philadelphia-1 and Knoxville was observed, while no binding was detected to seven members of the families Enterobacteriaceae, Pseudomonadaceae or Clostridiaceae. Production of this antibody in the recombinant scFv-Fc format using either a murine or a human Fc part allowed the set-up of a sandwich-ELISA for detection of Legionella cells. The scFv-Fc construct proved to be very stable, even when stored for several weeks at elevated temperatures. A sensitivity limit of 4,000 cells was achieved. The scFv-Fc antibody pair was integrated on a biosensor, demonstrating the specific and fast detection of L. pneumophila on a portable device. With this system, 10,000 Legionella cells were detected within 35 min. Combined with a water filtration/concentration system, this antibody may be developed into a promising reagent for rapid on-site Legionella monitoring.

  3. Legionella (Legionnaires' Disease and Pontiac Fever): History and Disease Patterns

    MedlinePlus

    ... Outbreaks (URDO) European Legionnaires’ Disease Surveillance Network (ELDSNet) History, Burden, and Trends Language: English (US) Español (Spanish) ... caused by a type of bacteria called Legionella . History Legionella was discovered after an outbreak in 1976 ...

  4. Problems associated with identification of Legionella species from the environment and isolation of six possible new species

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilkinson, I.J.; Sangster, N.; Ratcliff, R.M.

    1990-03-01

    Following investigation of an outbreak of legionellosis in South Australia, numerous Legionella-like organisms were isolated from water samples. Because of the limited number of commercially available direct fluorescent-antibody reagents and the cross-reactions found with some reagents, non-pneumophila legionellae proved to be difficult to identify and these isolates were stored at -70{degree}C for later study. Latex agglutination reagents for Legionella peneumpphila and Legionella anisa developed by the Institute of Medical and Veterinary Science, Adelaide, Australia, were found to be useful as rapid screening aids. Autofluorescence was useful for placing isolates into broad groups. Cellular fatty acid analysis, ubiquinone analysis, and DNAmore » hybridization techniques were necessary to provide definitive identification. The species which were isolated most frequently were L. pneumophila, followed by L. anisa, Legionella jamestowniensis, Legionella quinlivanii, Legionella rubrilucens, Legionella spiritensis, and a single isolate each of Legionella erythra, Legionella jordanis, Legionella birminghamensis, and Legionella cincinnatiensis. In addition, 10 isolates were found by DNA hybridization studies to be unrelated to any of the 26 currently known species, representing what the authors believe to be 6 possible new species.« less

  5. Legionella in Puerto Rico cooling towers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Negron-Alviro, A.; Perez-Suarez, I.; Hazen, T.C.

    1988-12-31

    Water samples from air conditioning cooling towers receiving different treatment protocols on five large municipal buildings in San Juan, Puerto Rico were assayed for various species and serogroups of Legionella spp. using direct immunofluorescence. Several water quality parameters were also measured with each sample. Guinea pigs were inoculated with water samples to confirm pathogenicity and recover viable organisms. Legionella pneumophila (1-6), L. bozemanii, L. micdadei, L. dumoffii, and L. gormanii were observed in at least one of the cooling towers. L. pneumophila was the most abundant species, reaching 10{sup 5} cells/ml, within the range that is considered potentially pathogenic tomore » humans. A significantly higher density of L. pneumophila was observed in the cooling tower water that was not being treated with biocides. Percent respiration (INT) and total cell activity (AODC), were inversely correlated with bacterial density. This study demonstrates that Legionella spp. are present in tropical air-conditioning cooling systems, and without continuous biocide treatment may reach densities that present a health risk.« less

  6. Quantitative Real-Time Legionella PCR for Environmental Water Samples: Data Interpretation

    PubMed Central

    Joly, Philippe; Falconnet, Pierre-Alain; André, Janine; Weill, Nicole; Reyrolle, Monique; Vandenesch, François; Maurin, Max; Etienne, Jerome; Jarraud, Sophie

    2006-01-01

    Quantitative Legionella PCRs targeting the 16S rRNA gene (specific for the genus Legionella) and the mip gene (specific for the species Legionella pneumophila) were applied to a total of 223 hot water system samples (131 in one laboratory and 92 in another laboratory) and 37 cooling tower samples (all in the same laboratory). The PCR results were compared with those of conventional culture. 16S rRNA gene PCR results were nonquantifiable for 2.8% of cooling tower samples and up to 39.1% of hot water system samples, and this was highly predictive of Legionella CFU counts below 250/liter. PCR cutoff values for identifying hot water system samples containing >103 CFU/liter legionellae were determined separately in each laboratory. The cutoffs differed widely between the laboratories and had sensitivities from 87.7 to 92.9% and specificities from 77.3 to 96.5%. The best specificity was obtained with mip PCR. PCR cutoffs could not be determined for cooling tower samples, as the results were highly variable and often high for culture-negative samples. Thus, quantitative Legionella PCR appears to be applicable to samples from hot water systems, but the positivity cutoff has to be determined in each laboratory. PMID:16597985

  7. Chest radiographic characteristics of community-acquired Legionella pneumonia in the elderly.

    PubMed

    Zhang, Zhigang; Liu, Xinmin; Chen, Luzeng; Qiu, Jianxing

    2014-01-01

    Legionella is an important community-acquired pneumonia pathogen. Although the elderly are especially susceptible to Legionella, few studies have looked at comparative radiographic features of Legionella pneumonia in this population. The aim of this study was to explore the chest radiographic characteristics of community-acquired Legionella pneumonia in the elderly. Serial chest radiographs obtained in 34 patients hospitalized with serologically proven Legionella pneumonia were retrospectively reviewed. Chest X-ray features of an aged group of ≥ 65 years were assessed and compared with a non-aged group of <65 years old with regard to initial patterns and distributions of pulmonary abnormalities, accompanying signs, and progression. The most common initial presentation was a patchy alveolar infiltrate involving a single lobe, most often the lower lobe. There was no middle or lingular lobe involvement in the aged group patients, but bilateral pleural effusion was significantly more common in this group. In the aged group patients, radiographic progression following adequate therapy, despite a clinical response, was more often noted and the radiographs were less likely to have returned to the premorbid state at discharge, but the differences were not significant between the two groups. The discrepancy between imaging findings and clinical symptoms seems more prominent in community-acquired Legionella pneumonia in the elderly.

  8. Implementation of a Legionella Ordinance for Multifamily Housing, Garland, Texas.

    PubMed

    Whitney, Ellen A; Blake, Sarah; Berkelman, Ruth L

    The incidence of legionellosis has sharply increased in the United States as a result of contaminated water systems. Jurisdictions across the country are considering whether to develop and implement regulations to protect individuals against Legionnaires' disease with its associated high morbidity and mortality. This article sheds light on the implementation and effectiveness of a 2005 citywide Legionella testing mandate of multifamily housing cooling towers in Garland, Texas. This ordinance has been in place for more than 10 years and represents the first of its kind in the United States to mandate routine testing of cooling towers for Legionella in multifamily housing. We utilized a mix of both qualitative and quantitative methods to explore the development, adoption, and implementation of the ordinance. Phone interviews were conducted with individuals from the City of Garland Health Department and apartment managers. Quantitative data included public health surveillance data on legionellosis. Barriers and facilitators of implementation, number and percentage of cooling towers from multifamily housing units that tested positive for Legionella by year, and number of legionellosis cases by year in Garland, Texas. Study outcomes highlight key themes that facilitated the successful implementation of the Legionella testing mandate, including the importance of timing, leadership support, stakeholder engagement, and education and outreach. The number of contaminated cooling towers was reduced over time. Mandatory monitoring for legionella in a local jurisdiction may result in reduced risk of legionellosis from cooling towers through raising awareness and education of building owners and managers about the need to prevent, detect, and remediate legionella contamination in their building water systems. Garland, Texas, broke new ground in the United States in moving toward primary prevention of legionellosis. The ordinance may be useful both in serving to educate and

  9. Approach to determine the diversity of Legionella species by nested PCR-DGGE in aquatic environments.

    PubMed

    Huang, Wen-Chien; Tsai, Hsin-Chi; Tao, Chi-Wei; Chen, Jung-Sheng; Shih, Yi-Jia; Kao, Po-Min; Huang, Tung-Yi; Hsu, Bing-Mu

    2017-01-01

    In this study, we describe a nested PCR-DGGE strategy to detect Legionella communities from river water samples. The nearly full-length 16S rRNA gene was amplified using bacterial primer in the first step. After, the amplicons were employed as DNA templates in the second PCR using Legionella specific primer. The third round of gene amplification was conducted to gain PCR fragments apposite for DGGE analysis. Then the total numbers of amplified genes were observed in DGGE bands of products gained with primers specific for the diversity of Legionella species. The DGGE patterns are thus potential for a high-throughput preliminary determination of aquatic environmental Legionella species before sequencing. Comparative DNA sequence analysis of excised DGGE unique band patterns showed the identity of the Legionella community members, including a reference profile with two pathogenic species of Legionella strains. In addition, only members of Legionella pneumophila and uncultured Legionella sp. were detected. Development of three step nested PCR-DGGE tactic is seen as a useful method for studying the diversity of Legionella community. The method is rapid and provided sequence information for phylogenetic analysis.

  10. Approach to determine the diversity of Legionella species by nested PCR-DGGE in aquatic environments

    PubMed Central

    Huang, Wen-Chien; Tsai, Hsin-Chi; Tao, Chi-Wei; Chen, Jung-Sheng; Shih, Yi-Jia; Kao, Po-Min; Huang, Tung-Yi; Hsu, Bing-Mu

    2017-01-01

    In this study, we describe a nested PCR-DGGE strategy to detect Legionella communities from river water samples. The nearly full-length 16S rRNA gene was amplified using bacterial primer in the first step. After, the amplicons were employed as DNA templates in the second PCR using Legionella specific primer. The third round of gene amplification was conducted to gain PCR fragments apposite for DGGE analysis. Then the total numbers of amplified genes were observed in DGGE bands of products gained with primers specific for the diversity of Legionella species. The DGGE patterns are thus potential for a high-throughput preliminary determination of aquatic environmental Legionella species before sequencing. Comparative DNA sequence analysis of excised DGGE unique band patterns showed the identity of the Legionella community members, including a reference profile with two pathogenic species of Legionella strains. In addition, only members of Legionella pneumophila and uncultured Legionella sp. were detected. Development of three step nested PCR-DGGE tactic is seen as a useful method for studying the diversity of Legionella community. The method is rapid and provided sequence information for phylogenetic analysis. PMID:28166249

  11. Usefulness of Fatty Acid Composition for Differentiation of Legionella Species

    PubMed Central

    Diogo, Alexandra; Veríssimo, António; Nobre, M. Fernanda; da Costa, Milton S.

    1999-01-01

    Numerical analysis of fatty acid methyl ester (FAME) profiles of 199 isolates and 76 reference strains, belonging to all validly described species of the genus Legionella that can be cultured in laboratory media, was used to differentiate between the species of this genus. With the exception of the strains that autofluoresced red, it was possible to differentiate all the other Legionella species. The strains of the species L. bozemanii, L. dumoffii, L. feeleii, L. gormanii, L. maceachernii, L. micdadei, and L. quinlivanii did not form single clusters, showing some degree of variability in the fatty acid compositions. The strains of the blue-white autofluorescent species had very similar fatty acid compositions and were difficult to distinguish from each other. Nine isolates had fatty acid profiles unlike those of any of the validly described species and may represent different FAME groups of known species or undescribed Legionella species. The method used in this study was useful for screening and discriminating large number of isolates of Legionella species. Moreover, the results obtained can be included in a database of fatty acid profiles, leading to a more accurate automatic identification of Legionella isolates. PMID:10364593

  12. Prevalence of Legionella in premise plumbing in Hungary.

    PubMed

    Barna, Zsófia; Kádár, Mihály; Kálmán, Emese; Scheirich Szax, Anita; Vargha, Márta

    2016-03-01

    Legionella is one of the emerging concerns of water quality in built water environments. Premise plumbing systems are among the recognised sources of infection. In the present study, colonisation of hot water networks in health care facilities, schools, hotels, private residences, office and industrial buildings was investigated. Data was analysed in connection with building and premise plumbing characteristics. Over 60% of all buildings were colonised by Legionella; counts were over 1000 CFU/L in 49%. The most prevalent type was Legionella pneumophila serogroup 2-14, isolated from 75% of the positive samples. Centrally produced hot water was found to be a key risk factor (46% of the samples were positive vs. 16% in individual systems); within this group the type of the building was less relevant. Colonisation levels in schools were similar to hotels or hospitals, representing a previously underestimated risk setting. Systems supplied by water from deep groundwater sources were significantly less likely to be colonised than more vulnerable sources (bank-wall filtration, surface water abstraction or karstic water; 28% vs. 51% positive), regardless of the type of treatment applied, including the presence of disinfection. The aggravating effect of larger, more complex and older buildings on colonisation was also confirmed. The present study represents the first baseline analysis, pre-empting regulation or monitoring requirements for Legionella. The prevalence of legionellae and the identified risk factors are indicative for other settings lacking targeted interventions. The statistically confirmed risk factors can serve as indicators for preliminary risk assessment and the prioritisation of interventions. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Survival and multiplication of Legionella pneumophila in municipal drinking water systems.

    PubMed Central

    States, S J; Conley, L F; Kuchta, J M; Oleck, B M; Lipovich, M J; Wolford, R S; Wadowsky, R M; McNamara, A M; Sykora, J L; Keleti, G

    1987-01-01

    Studies were conducted to investigate the survival and multiplication of Legionella spp. in public drinking water supplies. An attempt was made, over a period of several years, to isolate legionellae from a municipal system. Sampling sites included the river water supply, treatment plant, finished water reservoir system, mains, and distribution taps. Despite the use of several isolation techniques, Legionella spp. could not be detected in any of the samples other than those collected from the river. It was hypothesized that this was due to the maintenance of a chlorine residual throughout the system. To investigate the potential for Legionella growth, additional water samples, collected from throughout the system, were dechlorinated, pasteurized, and inoculated with Legionella pneumophila. Subsequent growth indicated that many of these samples, especially those collected from areas affected by an accumulation of algal materials, exhibited a much greater ability to support Legionella multiplication than did river water prior to treatment. Chemical analyses were also performed on these samples. Correlation of chemical data and experimental growth results indicated that the chemical environment significantly affects the ability of the water to support multiplication, with turbidity, organic carbon, and certain metals being of particular importance. These studies indicate that the potential exists for Legionella growth within municipal systems and support the hypothesis that public water supplies may contaminate the plumbing systems of hospitals and other large buildings. The results also suggest that useful methods to control this contamination include adequate treatment plant filtration, maintenance of a chlorine residual throughout the treatment and distribution network, and effective covering of open reservoirs. PMID:3606101

  14. An outbreak of Legionella pneumonia originating from a cooling tower.

    PubMed

    Isozumi, Rie; Ito, Yutaka; Ito, Isao; Osawa, Makoto; Hirai, Toyohiro; Takakura, Syunji; Iinuma, Yoshitsugu; Ichiyama, Satoshi; Tateda, Kazuhiro; Yamaguchi, Keizo; Mishima, Michiaki

    2005-01-01

    We report 2 cases of Legionella pneumonia in individuals who were exposed to aerosols during maintenance of a cooling tower at a waste processing plant. This report documents the first known occupation-related outbreak of Legionella pneumonia in Japan.

  15. Legionella prevalence and risk of legionellosis in Hungarian hospitals.

    PubMed

    Barna, Zsófia; Kádár, Mihály; Kálmán, Emese; Róka, Eszter; Szax, Anita Sch; Vargha, Márta

    2015-12-01

    Nosocomial legionellosis is a growing concern worldwide. In Hungary, about 20% of the reported cases are health-care associated, but in the absence of legal regulation, environmental monitoring of Legionella is not routinely performed in hospitals. In the present study, 23 hospitals were investigated. The hot water distribution system was colonized by Legionella in over 90%; counts generally exceeded the public health limit value. Hot water temperature was critically low in all systems (<45 °C), and large differences (3-38 °C temperature drop) were observed within buildings, indicating insufficient circulation. Most facilities were older than 30 years (77%); however, new systems (n = 3) were also shown to be rapidly colonized at low hot water temperature. Vulnerable source of drinking water, complex distribution system, and large volume hot water storage increased the risk of Legionella prevalence (OR = 28.0, 27.3, 27.7, respectively). Risk management interventions (including thermal or chemical disinfection) were only efficient if the system operation was optimized. Though the risk factors were similar, in those hospitals where nosocomial legionellosis was reported, Legionella counts and the proportion of L. pneumophila sg 1 isolates were significantly higher. The results of environmental prevalence of legionellae in hospitals suggest that the incidence of nosocomial legionellosis is likely to be underreported. The observed colonization rates call for the introduction of a mandatory environmental monitoring scheme.

  16. A comparison of assays measuring the viability of Legionella ...

    EPA Pesticide Factsheets

    Background: The relatively high prevalence of Legionella pneumophila in premise plumbing systems has been widely reported. Published reports indicate Legionella has a comparatively high resistance to chlorine and moreover has the ability to grow in phagocytic amoeba which could provide additional protection in chlorinated drinking water distribution systems. Copper-Silver (Cu-Ag) ionization treatment systems are commercially available for use in large building water systems to help control the risks from Legionella bacteria. The objectives of this study were to develop and optimize Legionella viability assays and use them to investigate the viability of Legionella bacteria after exposure to water treated with coppper and silver ions. Methods: Log phase L. pneumophila cells were used in all experiments and were generated by incubation at 35C for 48 hours in buffered yeast extract broth. Viability assays used included plating on buffered charcoal yeast extract agar to determine the number of culturable cells and treating cells with propidium monoazide (PMA) or ethidium monoazide (EMA) followed by quantitative PCR targeting mip gene of L. pneumophila. The qPCR viability assays were optimized using L. pneumophila inactivated by heat treatment at 65C for 60 min. The effectiveness of Cu-Ag ionization treatment was studied by inoculating L. pneumonia at 105 CFU/mL in water collected directly from a building water system that employed this technology and incubat

  17. Laboratory observations of biocide efficiency against Legionella in model cooling tower systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, W.M.; Eccles, J.; Fricker, C.

    1999-07-01

    The efficacy of specific oxidizing and non-oxidizing biocides was examined using a model cooling system inoculated with a microcosm containing an environmental isolate of Legionella pneumophila. The microcosm was prepared in a two-stage chemostat, which provided a consistent source of microbiological inoculum for the study. The microcosm consisted of both sessile (within biofilms) and planktonic Legionella in association with other microorganisms, including Pseudomonas species and cyst-forming ameobae. A procedure was established to successfully transfer the chemostat grown inoculum to the model cooling system and establish both sessile and planktonic forms of Legionella in the model cooling system. The greatest biocidalmore » effect for all of the biocides was observed immediately after dosing. This effect was relatively short-lived even for the slow acting biocides such isothiazolin (as 8 ppm active) where an effect was only observed over the first 12 hours. The faster acting biocides, DBNPA (as 8 ppm active) and gluteraldehyde (as 27 ppm active), did initially reduce Legionella populations but did not totally eliminate Legionella or provide lasting control. Chlorine and bromine (as 0.5--1.5 ppm free halogen), and ozone (as 0.1--0.5 ppm free reserve) reduced and controlled Legionella populations so long as a free reserve of oxidant was maintained. Legionella recovered quickly after biocide dosing, reestablishing similar levels to those observed before dosing.« less

  18. A comparison of legionella and other bacteria concentrations in cooling tower water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cappabianca, R.M.; Jurinski, N.B.; Jurinski, J.B.

    1994-05-01

    A field study was conducted in which water samples collected from air conditioning cooling water reservoirs of high-rise buildings throughout an urban area were assayed for Legionella and for total bacteria. Buildings included within the study had ongoing biocidal treatment programs for the cooling towers. Separate sample analyses were performed to measure the viable colony concentrations of total bacteria and of Legionella in the process waters. The occurrence and viable counts of Legionella in 304 environmental water samples were determined by inoculating them onto plates of buffered charcoal yeast extract (BCYE) agar medium (a presumptive screening method). The samples weremore » collected during summer months between July and September. BCYE plate cultures of 50 (16.4%) of the samples yielded Legionella with viable counts ranging from 2 to 608 colony forming units per milliliter. In the water samples, 281 (92.4%) yielded viable counts of bacteria that ranged from 9 to 1.2 x 10{sup 6} per milliliter. This study demonstrates that Legionella are commonly present in the water of air conditioning cooling towers and that there is no significant correlation between concurrently sampled culture plate counts of Legionella and total bacteria plate counts. Correspondingly, there is no demonstrated validity for use of total bacterial counts as an inferential surrogate for the concentration of Legionella in the water. 19 refs., 3 figs., 1 tab.« less

  19. The surfactant of Legionella pneumophila Is secreted in a TolC-dependent manner and is antagonistic toward other Legionella species.

    PubMed

    Stewart, Catherine R; Burnside, Denise M; Cianciotto, Nicholas P

    2011-11-01

    When Legionella pneumophila grows on agar plates, it secretes a surfactant that promotes flagellum- and pilus-independent "sliding" motility. We isolated three mutants that were defective for surfactant. The first two had mutations in genes predicted to encode cytoplasmic enzymes involved in lipid metabolism. These genes mapped to two adjacent operons that we designated bbcABCDEF and bbcGHIJK. Backcrossing and complementation confirmed the importance of the bbc genes and suggested that the Legionella surfactant is lipid containing. The third mutant had an insertion in tolC. TolC is the outer membrane part of various trimolecular complexes involved in multidrug efflux and type I protein secretion. Complementation of the tolC mutant restored sliding motility. Mutants defective for an inner membrane partner of TolC also lacked a surfactant, confirming that TolC promotes surfactant secretion. L. pneumophila (lspF) mutants lacking type II protein secretion (T2S) are also impaired for a surfactant. When the tolC and lspF mutants were grown next to each other, the lsp mutant secreted surfactant, suggesting that TolC and T2S conjoin to mediate surfactant secretion, with one being the conduit for surfactant export and the other the exporter of a molecule that is required for induction or maturation of surfactant synthesis/secretion. Although the surfactant was not required for the extracellular growth, intracellular infection, and intrapulmonary survival of L. pneumophila, it exhibited antimicrobial activity toward seven other species of Legionella but not toward various non-Legionella species. These data suggest that the surfactant provides L. pneumophila with a selective advantage over other legionellae in the natural environment.

  20. An in-premise model for Legionella exposure during showering events

    EPA Science Inventory

    An exposure model was constructed to predict the critical Legionella densities in an engineered water system that might result in infection from inhalation of aerosols containing the pathogen while showering. The model predicted the Legionella densities in the shower air, water ...

  1. Determination of viable legionellae in engineered water systems: Do we find what we are looking for?

    PubMed Central

    Kirschner, Alexander K.T.

    2016-01-01

    In developed countries, legionellae are one of the most important water-based bacterial pathogens caused by management failure of engineered water systems. For routine surveillance of legionellae in engineered water systems and outbreak investigations, cultivation-based standard techniques are currently applied. However, in many cases culture-negative results are obtained despite the presence of viable legionellae, and clinical cases of legionellosis cannot be traced back to their respective contaminated water source. Among the various explanations for these discrepancies, the presence of viable but non-culturable (VBNC) Legionella cells has received increased attention in recent discussions and scientific literature. Alternative culture-independent methods to detect and quantify legionellae have been proposed in order to complement or even substitute the culture method in the future. Such methods should detect VBNC Legionella cells and provide a more comprehensive picture of the presence of legionellae in engineered water systems. However, it is still unclear whether and to what extent these VBNC legionellae are hazardous to human health. Current risk assessment models to predict the risk of legionellosis from Legionella concentrations in the investigated water systems contain many uncertainties and are mainly based on culture-based enumeration. If VBNC legionellae should be considered in future standard analysis, quantitative risk assessment models including VBNC legionellae must be proven to result in better estimates of human health risk than models based on cultivation alone. This review critically evaluates current methods to determine legionellae in the VBNC state, their potential to complement the standard culture-based method in the near future, and summarizes current knowledge on the threat that VBNC legionellae may pose to human health. PMID:26928563

  2. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry and database for identification of Legionella species.

    PubMed

    He, Ying; Chang, Tsung C; Li, Haijing; Shi, Gongyi; Tang, Yi-Wei

    2011-07-01

    More than 20 species of Legionella have been identified in relation to human infections. Rapid detection and identification of Legionella isolates is clinically useful to differentiate between infection and contamination and to determine treatment regimens. We explored the use of matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) Biotyper system (Bruker Daltonik GmbH, Bremen, Germany) for the identification of Legionella species. The MALDI MS spectra were generated and compared with the Biotyper database, which includes 25 Legionella strains covering 22 species and four Legionella pneumophila serogroups. A total of 83 blind-coded Legionella strains, consisting of 54 reference and 29 clinical strains, were analyzed in the study. Overall, the Biotyper system correctly identified 51 (61.4%) of all strains and isolates to the species level. For species included in the Biotyper database, the method identified 51 (86.4%) strains out of 59 Legionella strains to the correct species level, including 24 (100%) L. pneumophila and 27 (77.1%) non-L. pneumophila strains. The remaining 24 Legionella strains, belonging to species not covered by the Biotyper database, were either identified to the Legionella genus level or had no reliable identification. The Biotyper system produces constant and reproducible MALDI MS spectra for Legionella strains and can be used for rapid and accurate Legionella identification. More Legionella strains, especially the non-L. pneumophila strains, need to be included in the current Biotyper database to cover varieties of Legionella species and to increase identification accuracy.

  3. Application of TaqMan fluorescent probe-based quantitative real-time PCR assay for the environmental survey of Legionella spp. and Legionella pneumophila in drinking water reservoirs in Taiwan.

    PubMed

    Kao, Po-Min; Hsu, Bing-Mu; Hsu, Tsui-Kang; Ji, Wen-Tsai; Huang, Po-Hsiang; Hsueh, Chih-Jen; Chiang, Chuen-Sheue; Huang, Shih-Wei; Huang, Yu-Li

    2014-08-15

    In this study, TaqMan fluorescent quantitative real-time PCR was performed to quantify Legionella species in reservoirs. Water samples were collected from 19 main reservoirs in Taiwan, and 12 (63.2%) were found to contain Legionella spp. The identified species included uncultured Legionella spp., L. pneumophila, L. jordanis, and L. drancourtii. The concentrations of Legionella spp. and L. pneumophila in the water samples were in the range of 1.8×10(2)-2.6×10(3) and 1.6×10(2)-2.4×10(2) cells/L, respectively. The presence and absence of Legionella spp. in the reservoir differed significantly in pH values. These results highlight the importance that L. pneumophila, L. jordanis, and L. drancourtii are potential pathogens in the reservoirs. The presence of L. pneumophila in reservoirs may be a potential public health concern that must be further examined. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Legionella in industrial cooling towers: monitoring and control strategies.

    PubMed

    Carducci, A; Verani, M; Battistini, R

    2010-01-01

    Legionella contamination of industrial cooling towers has been identified as the cause of sporadic cases and outbreaks of legionellosis among people living nearby. To evaluate and control Legionella contamination in industrial cooling tower water, microbiological monitoring was carried out to determine the effectiveness of the following different disinfection treatments: (i) continuous chlorine concentration of 0.01 ppm and monthly chlorine shock dosing (5 ppm) on a single cooling tower; (ii) continuous chlorine concentration of 0.4 ppm and monthly shock of biocide P3 FERROCID 8580 (BKG Water Solution) on seven towers. Legionella spp. and total bacterial count (TBC) were determined 3 days before and after each shock dose. Both strategies demonstrated that when chlorine was maintained at low levels, the Legionella count grew to levels above 10(4) CFU l(-1) while TBC still remained above 10(8 )CFU l(-1). Chlorine shock dosing was able to eliminate bacterial contamination, but only for 10-15 days. Biocide shock dosing was also insufficient to control the problem when the disinfectant concentration was administered at only one point in the plant and at the concentration of 30 ppm. On the other hand, when at a biocide concentration of 30 or 50 ppm was distributed throughout a number of points, depending on the plant hydrodynamics, Legionella counts decreased significantly and often remained below the warning limit. Moreover, the contamination of water entering the plant and the presence of sediment were also important factors for Legionella growth. For effective decontamination of outdoor industrial cooling towers, disinfectants should be distributed in a targeted way, taking into account the possible sources of contamination. The data of the research permitted to modify the procedure of disinfection for better reduce the water and aerosol contamination and consequently the exposure risk.

  5. Legionella pathogenicity: genome structure, regulatory networks and the host cell response.

    PubMed

    Steinert, Michael; Heuner, Klaus; Buchrieser, Carmen; Albert-Weissenberger, Christiane; Glöckner, Gernot

    2007-11-01

    Legionella spp. the causative agent of Legionnaires' disease is naturally found in fresh water where the bacteria parasitize intracellularly within protozoa. Upon aerosol formation via man-made water systems, Legionella can enter the human lung and cause a severe form of pneumonia. Here we review results from systematic comparative genome analysis of Legionella species with different pathogenic potentials. The complete genomes reveal that horizontal gene transfer has played an important role during the evolution of Legionella and indicate the importance of secretion machineries for the intracellular lifestyle of this pathogen. Moreover, we highlight recent findings on the in vivo transcriptional program of L. pneumophila and the regulatory networks involved in the biphasic life cycle. In order to understand how Legionella effectively subvert host cell functions for its own benefit the transcriptional host cell response upon infection of the model amoeba Dictyostelium discoideum was studied. The use of this model organism made it possible to develop a roadmap of host cell factors which significantly contribute to the uptake of L. pneumophila and the establishment of an ER-associated replicative vacuole.

  6. Effectiveness of bromicide against Legionella pneumophila in a cooling tower

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fliermans, C.B.; Harvey, R.S.

    1983-01-01

    Cooling towers are considered to be man-made amplifiers of Legionella. Thus the proper maintenance and choice of biocides is important. The only biocide that has thus far been shown to be effective in field tests is the judicious use of chlorination. Perturbation studies were conducted on an industrial cooling tower shown to contain Legionella, using 1-bromo-3-chloro-5,5-dimethylhydantoin (Bromicide, Great Lakes Chemical Corp.). At the manufacturer's recommended concentrations neither the density nor the activity of Legionella was affected. At concentrations greater than 2.0 ppM free residual, the Bromicide was not effective in reducing Legionella to source water concentrations, nor was it effectivemore » in reducing the INT activity of the bacterium in situ. The data indicate that at concentrations up to 2.0 ppM, Bromicide is not effective in these tower studies. 23 references, 3 tables.« less

  7. Occurrence and Control of Legionella in Recycled Water Systems

    PubMed Central

    Jjemba, Patrick K.; Johnson, William; Bukhari, Zia; LeChevallier, Mark W.

    2015-01-01

    Legionella pneumophila is on the United States Environmental Protection Agency (USEPA) Candidate Contaminant list (CCL) as an important pathogen. It is commonly encountered in recycled water and is typically associated with amoeba, notably Naegleria fowleri (also on the CCL) and Acanthamoeba sp. No legionellosis outbreak has been linked to recycled water and it is important for the industry to proactively keep things that way. A review was conducted examine the occurrence of Legionella and its protozoa symbionts in recycled water with the aim of developing a risk management strategy. The review considered the intricate ecological relationships between Legionella and protozoa, methods for detecting both symbionts, and the efficacy of various disinfectants. PMID:26140674

  8. Determination of viable legionellae in engineered water systems: Do we find what we are looking for?

    PubMed

    Kirschner, Alexander K T

    2016-04-15

    In developed countries, legionellae are one of the most important water-based bacterial pathogens caused by management failure of engineered water systems. For routine surveillance of legionellae in engineered water systems and outbreak investigations, cultivation-based standard techniques are currently applied. However, in many cases culture-negative results are obtained despite the presence of viable legionellae, and clinical cases of legionellosis cannot be traced back to their respective contaminated water source. Among the various explanations for these discrepancies, the presence of viable but non-culturable (VBNC) Legionella cells has received increased attention in recent discussions and scientific literature. Alternative culture-independent methods to detect and quantify legionellae have been proposed in order to complement or even substitute the culture method in the future. Such methods should detect VBNC Legionella cells and provide a more comprehensive picture of the presence of legionellae in engineered water systems. However, it is still unclear whether and to what extent these VBNC legionellae are hazardous to human health. Current risk assessment models to predict the risk of legionellosis from Legionella concentrations in the investigated water systems contain many uncertainties and are mainly based on culture-based enumeration. If VBNC legionellae should be considered in future standard analysis, quantitative risk assessment models including VBNC legionellae must be proven to result in better estimates of human health risk than models based on cultivation alone. This review critically evaluates current methods to determine legionellae in the VBNC state, their potential to complement the standard culture-based method in the near future, and summarizes current knowledge on the threat that VBNC legionellae may pose to human health. Copyright © 2016 The Author. Published by Elsevier Ltd.. All rights reserved.

  9. Screening-level assays for potentially human-infectious environmental Legionella spp.

    EPA Science Inventory

    In spite of the fact that Legionella species can be isolated from nonclinical settings, there is no standard method to determine whether environmental legionellae may be infectious to humans. In this study, an in vivo murine model of pneumonia and three in vitro proliferation as...

  10. Persistent culture-positive Legionella infection in an immunocompromised host.

    PubMed

    O'Reilly, Katherine M A; Urban, Marguerite A; Barriero, Timothy; Betts, Robert F; Trawick, David R

    2005-05-15

    Legionella pneumophila is an important cause of community-acquired and nosocomial pneumonia. We describe an immunocompromised patient with severe pneumonia from whom Legionella species were isolated from sputum samples by culture for 30 days, despite administration of treatment with appropriate antimicrobial agents. However, clear improvement in the patient's respiratory condition was evident, and he subsequently recovered completely.

  11. Investigation of the prevalence of Legionella species in domestic hot water systems.

    PubMed

    Bates, M N; Maas, E; Martin, T; Harte, D; Grubner, M; Margolin, T

    2000-06-09

    To investigate the prevalence of Legionella spp. in the hot water systems of a representative sample of Wellington domestic residences with electrically heated hot water systems, and to investigate risk factors (eg water temperature, plumbing materials) for such contamination. 100 households with electrically heated hot water systems in the Wellington area were investigated. Samples of hot water from several hot water outlets were collected, and characteristics of the plumbing system were recorded. Water samples and swabs were cultured and further examined by polymerase chain reaction (PCR) and direct fluorescence antibody (DFA) testing to identify Legionella spp. and serogroups. No Legionella spp. were isolated by culture. PCR tested positive for Legionella in specimens from twelve residences. Six of these were also positive by DFA testing. The only environmental factor found to be associated with the presence of Legionella was recent plumbing work on the hot water system. Five of the twelve PCR-positive residences, and four of the six DFA-confirmed residences had hot water delivery temperatures in excess of 60 degrees C. The results suggest that either Legionellae colonise domestic hot water reticulation systems and/or that the organisms are killed during passage through the hot water tank. Both possibilities may be correct. Further work to characterise the microbial ecology of Legionella-positive hot water distribution systems would be useful, as would the development of improved methods for culturing the organisms from potable water.

  12. Legionella saoudiensis sp. nov., isolated from a sewage water sample.

    PubMed

    Bajrai, Leena Hussein; Azhar, Esam Ibraheem; Yasir, Muhammad; Jardot, Priscilla; Barrassi, Lina; Raoult, Didier; La Scola, Bernard; Pagnier, Isabelle

    2016-11-01

    A Gram-stain-negative, bacilli-shaped bacterial strain, LS-1T, was isolated from a sewage water sample collected in Jeddah, Saudi Arabia. The taxonomic position of strain LS-1T was investigated using a polyphasic taxonomic approach. Phylogenetic analysis based on 16S rRNA gene sequences and those of four other genes indicated that strain LS-1T belongs to the genus Legionella in the family Legionellaceae. Regarding the 16S rRNA gene, the most closely related species are Legionella rowbothamii LLAP-6T (98.6 %) and Legionella lytica L2T (98.5 %). The mip gene sequence of strain LS-1T showed 94 % sequence similarity with that of L. lytica L2T and 93 % similarity with that of L. rowbothamii LLAP-6T. Strain LS-1T grew optimally at a temperature of 32 °C on a buffered charcoal yeast extract (BCYE) agar plate in a 5 % CO2 atmosphere and had a flagellum. The combined phylogenetic, phenotypic and genomic sequence data suggest that strain LS-1T represents a novel species of the genus Legionella, for which the name Legionella saoudiensis sp. nov. is proposed. The type strain is LS-1T (=DSM 101682T=CSUR P2101T).

  13. Activities of tigecycline and comparators against Legionella pneumophila and Legionella micdadei extracellularly and in human monocyte-derived macrophages.

    PubMed

    Bopp, Lawrence H; Baltch, Aldona L; Ritz, William J; Michelsen, Phyllis B; Smith, Raymond P

    2011-01-01

    The activity of tigecycline against Legionellae, which are intracellular pathogens, was evaluated intracellularly in human phagocytes and extracellularly, and compared to the activities of erythromycin and levofloxacin. Clinical isolates of L. pneumophila serogroups 1, 5, and 6 and L. micdadei were tested in time-kill experiments. Extracellular experiments were done using buffered yeast extract broth. For intracellular assays, monolayers of human monocyte-derived macrophages (MDM) were infected with L. pneumophila or L. micdadei. Antibiotics (0.05-2.5 × MIC) were then added. MDM were lysed at 0, 24, 48, and 72 h and viable bacteria in the lysates were enumerated. Based on multiples of the MICs, tigecycline was less active extracellularly than levofloxacin or erythromycin. However, intracellular killing of both L. pneumophila and L. micdadei by tigecycline at 72 h was greater than for erythromycin or levofloxacin. Currently, evidence does not support the use of tigecycline as a first-line drug for treatment of Legionella infections. However, since Legionellae are intracellular pathogens, these results suggest that tigecycline should be effective for treatment of infections caused by these bacteria. Published by Elsevier Inc.

  14. [Antimicrobial susceptibility patterns of Legionella isolates in the environment and in patients].

    PubMed

    Choi, Go Eun; Kang, Jeong Eun; Lee, Eun Yup; Chang, Chulhun L; Tateda, Kazuhiro; Yamaguchi, Keizo; Kim, Kyeong Hee; Kim, Jeong Man

    2010-02-01

    Antimicrobial susceptibility of Legionella spp. has rarely been studied in Korea. Therefore, we aimed to determine the susceptibility of Legionella spp. to various antibiotics. We assessed the antimicrobial susceptibility of 66 environmental and clinical Legionella isolates collected between January 2001 and December 2008 from Korea and Japan. The minimum inhibitory concentrations (MICs) of 6 antibiotics, namely, azithromycin, ciprofloxacin, clarithromycin, clindamycin, gatifloxacin, and gemifloxacin were determined by the broth microdilution method using buffered starch yeast extract broth. The MIC ranges of the 6 antibiotics used against the Legionella isolates were as follows: 0.004-0.062 microg/mL (azithromycin), 0.002-0.5 microg/mL (ciprofloxacin), 0.004-0.5 microg/mL (clarithromycin), 0.12-4 microg/mL (clindamycin), 0.002-0.12 microg/mL (gatifloxacin), and 0.008-1 microg/mL (gemifloxacin). Legionella spp. isolates from Korea and Japan were most susceptible to gatifloxacin. Azithromycin, clarithromycin, ciprofloxacin, and gemifloxacin were also effective for treating legionellosis.

  15. Legionnaire disease organism, legionella (image)

    MedlinePlus

    Legionnaire disease was first described in 1976 after an outbreak of fatal pneumonia at a Legionnaires convention. The newly described organism which caused the disease was named Legionella pneumophila, shown in this picture. ( ...

  16. A case of nosocomial Legionella pneumonia associated with a contaminated hospital cooling tower.

    PubMed

    Osawa, Kayo; Shigemura, Katsumi; Abe, Yasuhisa; Jikimoto, Takumi; Yoshida, Hiroyuki; Fujisawa, Masato; Arakawa, Soichi

    2014-01-01

    We report the epidemiological investigation of a nosocomial pneumonia case due to Legionella pneumophila linked to a contaminated hospital cooling tower in an immune-compromised patient. A 73-year-old female patient was diagnosed with nosocomial Legionella pneumonia proven by a culture of L. pneumophila serogroup 1 from bronchoalveolar lavage fluid. Two strains isolated from the patient and two strains isolated from two cooling towers were found to be identical using repetitive-sequence-based-PCR with a 95% probability. This Legionella pneumonia case might be caused by aerosol from cooling towers on the roof of the hospital building which was contaminated by L. pneumophila. We increased up the temperature of hot water supply appropriately for prevention of Legionella breeding in an environment of patients' living. On the other hand, as the maintenance of cooling tower, we increased the frequency of Legionella culture tests from twice a year to three times a year. In addition, we introduced an automated disinfectants insertion machine and added one antiseptic reagent (BALSTER ST-40 N, Tohzai Chemical Industry Co., Ltd., Kawasaki, Japan) after this Legionella disease, and thereafter, we have no additional cases of Legionella disease or detection of Legionella spp. from the cooling tower or hot water supply. This case demonstrates the importance of detecting the infection source and carrying out environmental maintenance in cooperation with the infection control team. Copyright © 2013 Japanese Society of Chemotherapy and the Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  17. Comparative analyses of Legionella species identifies genetic features of strains causing Legionnaires' disease.

    PubMed

    Gomez-Valero, Laura; Rusniok, Christophe; Rolando, Monica; Neou, Mario; Dervins-Ravault, Delphine; Demirtas, Jasmin; Rouy, Zoe; Moore, Robert J; Chen, Honglei; Petty, Nicola K; Jarraud, Sophie; Etienne, Jerome; Steinert, Michael; Heuner, Klaus; Gribaldo, Simonetta; Médigue, Claudine; Glöckner, Gernot; Hartland, Elizabeth L; Buchrieser, Carmen

    2014-01-01

    The genus Legionella comprises over 60 species. However, L. pneumophila and L. longbeachae alone cause over 95% of Legionnaires’ disease. To identify the genetic bases underlying the different capacities to cause disease we sequenced and compared the genomes of L. micdadei, L. hackeliae and L. fallonii (LLAP10), which are all rarely isolated from humans. We show that these Legionella species possess different virulence capacities in amoeba and macrophages, correlating with their occurrence in humans. Our comparative analysis of 11 Legionella genomes belonging to five species reveals highly heterogeneous genome content with over 60% representing species-specific genes; these comprise a complete prophage in L. micdadei, the first ever identified in a Legionella genome. Mobile elements are abundant in Legionella genomes; many encode type IV secretion systems for conjugative transfer, pointing to their importance for adaptation of the genus. The Dot/Icm secretion system is conserved, although the core set of substrates is small, as only 24 out of over 300 described Dot/Icm effector genes are present in all Legionella species. We also identified new eukaryotic motifs including thaumatin, synaptobrevin or clathrin/coatomer adaptine like domains. Legionella genomes are highly dynamic due to a large mobilome mainly comprising type IV secretion systems, while a minority of core substrates is shared among the diverse species. Eukaryotic like proteins and motifs remain a hallmark of the genus Legionella. Key factors such as proteins involved in oxygen binding, iron storage, host membrane transport and certain Dot/Icm substrates are specific features of disease-related strains.

  18. Implementation of a Legionella Ordinance for Multifamily Housing, Garland, Texas

    PubMed Central

    Whitney, Ellen A.; Blake, Sarah

    2017-01-01

    Context: The incidence of legionellosis has sharply increased in the United States as a result of contaminated water systems. Jurisdictions across the country are considering whether to develop and implement regulations to protect individuals against Legionnaires' disease with its associated high morbidity and mortality. Objective: This article sheds light on the implementation and effectiveness of a 2005 citywide Legionella testing mandate of multifamily housing cooling towers in Garland, Texas. This ordinance has been in place for more than 10 years and represents the first of its kind in the United States to mandate routine testing of cooling towers for Legionella in multifamily housing. Design, Setting, and Population: We utilized a mix of both qualitative and quantitative methods to explore the development, adoption, and implementation of the ordinance. Phone interviews were conducted with individuals from the City of Garland Health Department and apartment managers. Quantitative data included public health surveillance data on legionellosis. Main Outcome Measures: Barriers and facilitators of implementation, number and percentage of cooling towers from multifamily housing units that tested positive for Legionella by year, and number of legionellosis cases by year in Garland, Texas. Results: Study outcomes highlight key themes that facilitated the successful implementation of the Legionella testing mandate, including the importance of timing, leadership support, stakeholder engagement, and education and outreach. The number of contaminated cooling towers was reduced over time. Conclusion: Mandatory monitoring for legionella in a local jurisdiction may result in reduced risk of legionellosis from cooling towers through raising awareness and education of building owners and managers about the need to prevent, detect, and remediate legionella contamination in their building water systems. Garland, Texas, broke new ground in the United States in moving toward

  19. Endogenous lipoid pneumonia associated with Legionella pneumophila serogroup 1.

    PubMed

    Hui, Chee-Kin

    2013-03-01

    Endogenous lipoid pneumonia is an uncommon condition. This is a report of a 29-year-old woman diagnosed with endogenous lipoid pneumonia associated with Legionella pneumophila serogroup 1 infection. The patient's endogenous lipoid pneumonia resolved completely after treatment for Legionella pneumophila infection. This suggests that early diagnosis and aggressive treatment of the underlying infection may prevent any long-term sequelae of lipoid pneumonia.

  20. [Case of Legionella pneumonia caused by a household humidifier].

    PubMed

    Endo, Keiichi; Ito, Kazuhisa

    2009-05-01

    A 60-year-old-man with diabetes mellitus was admitted to our hospital because of pyrexia of up to 40 degrees and dyspnea. Chest radiograph revealed ground glass infiltrates in both lung fields. Legionella pneumonia was diagnosed as a consequence of the urinary examination performed for Legionella antigen detection; further, we initiated intravenous pazufloxacin administration. Despite an antibiotic, sivelestat sodium, and mechanical ventilation, the condition of the patient worsened and he died of respiratory failure 5 days following admission. Pulse-field gel electrophoresis (PFGE) was performed to investigate the route of infection: this technique was applied to patient sputum samples and water from the humidifier in the room of the patient. The same DNA pattern as Legionella pneumophilla serogroup 1 was identified via analysis with PFGE.

  1. Environmental Validation of Legionella Control in a VHA Facility Water System.

    PubMed

    Jinadatha, Chetan; Stock, Eileen M; Miller, Steve E; McCoy, William F

    2018-03-01

    OBJECTIVES We conducted this study to determine what sample volume, concentration, and limit of detection (LOD) are adequate for environmental validation of Legionella control. We also sought to determine whether time required to obtain culture results can be reduced compared to spread-plate culture method. We also assessed whether polymerase chain reaction (PCR) and in-field total heterotrophic aerobic bacteria (THAB) counts are reliable indicators of Legionella in water samples from buildings. DESIGN Comparative Legionella screening and diagnostics study for environmental validation of a healthcare building water system. SETTING Veterans Health Administration (VHA) facility water system in central Texas. METHODS We analyzed 50 water samples (26 hot, 24 cold) from 40 sinks and 10 showers using spread-plate cultures (International Standards Organization [ISO] 11731) on samples shipped overnight to the analytical lab. In-field, on-site cultures were obtained using the PVT (Phigenics Validation Test) culture dipslide-format sampler. A PCR assay for genus-level Legionella was performed on every sample. RESULTS No practical differences regardless of sample volume filtered were observed. Larger sample volumes yielded more detections of Legionella. No statistically significant differences at the 1 colony-forming unit (CFU)/mL or 10 CFU/mL LOD were observed. Approximately 75% less time was required when cultures were started in the field. The PCR results provided an early warning, which was confirmed by spread-plate cultures. The THAB results did not correlate with Legionella status. CONCLUSIONS For environmental validation at this facility, we confirmed that (1) 100 mL sample volumes were adequate, (2) 10× concentrations were adequate, (3) 10 CFU/mL LOD was adequate, (4) in-field cultures reliably reduced time to get results by 75%, (5) PCR provided a reliable early warning, and (6) THAB was not predictive of Legionella results. Infect Control Hosp Epidemiol 2018;39:259-266.

  2. Alkaline approach to treating cooling towers for control of Legionella pneumophila

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    States, S.J.; Conley, L.F.; Towner, S.G.

    1987-08-01

    Earlier field and laboratory studies have shown that Legionella species survive and multiply in the pH range 5.5 to 9.2. Additionally, the technical feasibility of operating cooling towers at elevated alkalinities and pH has previously been documented by published guidelines. The guidelines indicate that these conditions facilitate corrosion control and favor chlorine persistence which enhances the effectiveness of continuous chlorination in biofouling control. This information suggest that control of Legionella species in cooling towers can be accomplished by operating the towers under alkaline conditions. To test this possibility, we collected water samples over a period of months from a hospitalmore » cooling tower. The samples were analyzed for a variety of chemical parameters. Subsamples were pasteurized and inoculated with non-agar-passaged Legionella pneumophila which had been maintained in tap water. Correlation of subsequent Legionella growth with corresponding pH and alkalinity values revealed statistically significant inverse associations. These data support the hypothesis that operating cooling towers outside of the optimal conditions for Legionella growth (e.g., at elevated alkalinities and a pH greater than 9) may be a useful approach to controlling growth in this habitat.« less

  3. Legionella species colonization in cooling towers: risk factors and assessment of control measures.

    PubMed

    Mouchtouri, Varvara A; Goutziana, Georgia; Kremastinou, Jenny; Hadjichristodoulou, Christos

    2010-02-01

    Cooling towers can be colonized by Legionella spp, and inhalation of aerosols generated by their operation may cause Legionnaires' disease in susceptible hosts. Environmental investigations of Legionnaires' disease outbreaks linked with cooling towers have revealed poorly maintained systems, lack of control measures, and failure of system equipment. The purpose of this study was to identify Legionella-contaminated cooling towers, identify risk factors for contamination, and assess the effectiveness of control measures. A total of 96 cooling towers of public buildings were registered and inspected, and 130 samples were collected and microbiologically tested. Microbiological test results were associated with characteristics of cooling towers, water samples, inspection results, and maintenance practices. Of the total 96 cooling towers examined, 47 (48.9%) were colonized by Legionella spp, and 22 (22.9%) required remedial action. A total of 65 samples (50.0%) were positive (> or = 500 cfu L(-1)), and 30 (23%) were heavily contaminated (> or = 10(4) cfu L(-1)). Of the 69 isolates identified, 55 strains (79.7.%) were L pneumophila. Legionella colonization was positively associated with the absence of training on Legionella control (relative risk [RR] = 1.66; P = .02), absence of regular Legionella testing (RR = 2.07: P = .002), absence of sunlight protection (RR = 1.63: P = .02), with samples in which the free residual chlorine level in the water sample was < 0.5 mg/L (RR = 2.23; P = .01), and with total plate count (P =.001). Colonization was negatively associated with chemical disinfection (RR = 0.2; P = .0003) and with the presence of a risk assessment and management plan (RR = 0.12; P = .0005). A statistically significant higher age (P =.01) was found in legionellae-positive cooling towers (median, 17 years; interquartile range [IQR] =5.0 to 26.0 years) compared with noncolonized cooling towers (median age, 6 years; IQR =1.0 to 13.5 years). After the 22 legionellae

  4. Acanthamoeba and Dictyostelium as Cellular Models for Legionella Infection

    PubMed Central

    Swart, A. Leoni; Harrison, Christopher F.; Eichinger, Ludwig; Steinert, Michael; Hilbi, Hubert

    2018-01-01

    Environmental bacteria of the genus Legionella naturally parasitize free-living amoebae. Upon inhalation of bacteria-laden aerosols, the opportunistic pathogens grow intracellularly in alveolar macrophages and can cause a life-threatening pneumonia termed Legionnaires' disease. Intracellular replication in amoebae and macrophages takes place in a unique membrane-bound compartment, the Legionella-containing vacuole (LCV). LCV formation requires the bacterial Icm/Dot type IV secretion system, which translocates literally hundreds of “effector” proteins into host cells, where they modulate crucial cellular processes for the pathogen's benefit. The mechanism of LCV formation appears to be evolutionarily conserved, and therefore, amoebae are not only ecologically significant niches for Legionella spp., but also useful cellular models for eukaryotic phagocytes. In particular, Acanthamoeba castellanii and Dictyostelium discoideum emerged over the last years as versatile and powerful models. Using genetic, biochemical and cell biological approaches, molecular interactions between amoebae and Legionella pneumophila have recently been investigated in detail with a focus on the role of phosphoinositide lipids, small and large GTPases, autophagy components and the retromer complex, as well as on bacterial effectors targeting these host factors. PMID:29552544

  5. Cross-reactions in Legionella antisera with Bordetella pertussis strains.

    PubMed Central

    Benson, R F; Thacker, W L; Plikaytis, B B; Wilkinson, H W

    1987-01-01

    While preparing slide agglutination test antisera and immunofluorescence conjugates for the identification of Legionella species and serogroups, we found that several of the reagents cross-reacted with Bordetella pertussis strains. To determine the extent of this problem and to estimate the specificity of Legionella reagents, we tested slide agglutination test antisera against 22 species and 35 serogroups with 92 bacterial strains representing 19 genera. The only cross-reactions observed were with Legionella pneumophila serogroup 10, L. maceachernii, L. gormanii, and L. feeleii serogroup 1 antisera and 4 of 10 B. pertussis strains. Nineteen conjugates, previously available from the Centers for Disease Control but no longer distributed as reference reagents, were tested with the four cross-reactive B. pertussis strains. Two conjugates, L. micdadei and L. wadsworthii, stained three of the B. pertussis strains at a fluorescence intensity of greater than or equal to 3+. All cross-reactions were removed from the antisera and conjugates by absorption with the cross-reacting strain without diminishing the homologous reaction. Special emphasis should be placed on the identification and removal of cross-reactions in Legionella reagents with strains that have similar morphologic and growth characteristics. PMID:2883198

  6. Enhanced isolation of Legionella species from composted material.

    PubMed

    McCabe, S; Brown, A; Edwards, G F S; Lindsay, D

    2011-10-01

    Legionella pneumophila and Legionella species were isolated from composted material when freshly prepared buffered charcoal yeast extract (BCYE) was supplemented with glycine (1.5 g/L), polymyxin B sulfate (40 000 IU/L), vancomycin hydrochloride (0.5 mg/L) and cycloheximide (40 mg/L) (GVPC medium) and Modified Wadowsky-Yee (MWY) (Oxoid, Cambridge, UK) plates were used for cultivation, but not with commercially sourced pre-poured GVPC and MWY plates (Oxoid). Legionella cincinnatiensis and pathogenic L. pneumophila serogroup (Sg) 1 Benidorm and France/Allentown were identified, as well as a non-typeable (NT) strain of L. pneumophila. As most laboratories no longer produce their own media, this may contribute to the lack of positive cultures from composted material. The antigenicity of the NT strain is discussed. © 2011 The Authors. Clinical Microbiology and Infection © 2011 European Society of Clinical Microbiology and Infectious Diseases.

  7. Reduction of Legionella spp. in Water and in Soil by a Citrus Plant Extract Vapor

    PubMed Central

    Kurzbach, Elena; Score, Jodie; Tejpal, Jyoti; Chi Tangyie, George; Phillips, Carol

    2014-01-01

    Legionnaires' disease is a severe form of pneumonia caused by Legionella spp., organisms often isolated from environmental sources, including soil and water. Legionella spp. are capable of replicating intracellularly within free-living protozoa, and once this has occurred, Legionella is particularly resistant to disinfectants. Citrus essential oil (EO) vapors are effective antimicrobials against a range of microorganisms, with reductions of 5 log cells ml−1 on a variety of surfaces. The aim of this investigation was to assess the efficacy of a citrus EO vapor against Legionella spp. in water and in soil systems. Reductions of viable cells of Legionella pneumophila, Legionella longbeachae, Legionella bozemanii, and an intra-amoebal culture of Legionella pneumophila (water system only) were assessed in soil and in water after exposure to a citrus EO vapor at concentrations ranging from 3.75 mg/liter air to 15g/liter air. Antimicrobial efficacy via different delivery systems (passive and active sintering of the vapor) was determined in water, and gas chromatography-mass spectrometry (GC-MS) analysis of the antimicrobial components (linalool, citral, and β-pinene) was conducted. There was up to a 5-log cells ml−1 reduction in Legionella spp. in soil after exposure to the citrus EO vapors (15 mg/liter air). The most susceptible strain in water was L. pneumophila, with a 4-log cells ml−1 reduction after 24 h via sintering (15 g/liter air). Sintering the vapor through water increased the presence of the antimicrobial components, with a 61% increase of linalool. Therefore, the appropriate method of delivery of an antimicrobial citrus EO vapor may go some way in controlling Legionella spp. from environmental sources. PMID:25063652

  8. Legionella spp. in Puerto Rico cooling towers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Negron-Alvira, A.; Perez-Suarez, I.; Hazen, T.C.

    1988-10-01

    Water samples from air conditioning cooling towers receiving different treatment protocols on five large municipal buildings in San Juan, P.R., were assayed for various Legionella spp. and serogroups by using direct immunofluorescence. Several water quality parameters were also measured for each sample. Guinea pigs were inoculated with water samples to confirm pathogenicity and recover viable organisms. Legionella pneumophila serogroups 1 to 6, L. bozemanii, L. micdadei, L. dumoffii, and L. gormanii were observed in at least one of the cooling towers. L. pneumophila was the most abundant species; its density reached 10{sup 5} cells per ml, which is within themore » range that is considered potentially pathogenic to humans. A significantly higher density of L. pneumophila was observed in the cooling tower water that was not being treated with biocides. Percent respiration (INT) and total cell activity (acridine orange direct count) were inversely correlated with bacterial density. This study demonstrates that Legionella spp. are present in tropical air-conditioning cooling systems and that, without continuous biocide treatment, they may reach densities that present a health risk.« less

  9. Impact of a risk management plan on Legionella contamination of dental unit water.

    PubMed

    Leoni, Erica; Dallolio, Laura; Stagni, Francesca; Sanna, Tiziana; D'Alessandro, Giovanni; Piana, Gabriela

    2015-02-23

    The study aimed to assess the prevalence of Legionella spp. in dental unit waterlines of a dental clinic and to verify whether the microbiological parameters used as indicators of water quality were correlated with Legionella contamination. A risk management plan was subsequently implemented in the dental health care setting, in order to verify whether the adopted disinfection protocols were effective in preventing Legionella colonization. The water delivered from syringes and turbines of 63 dental units operating in a dental clinic, was monitored for counts of the heterotrophic bacteria P. aeruginosa and Legionella spp. (22 °C and 37 °C). At baseline, output water from dental units continuously treated with disinfection products was more compliant with the recommended standards than untreated and periodically treated water. However, continuous disinfection was still not able to prevent contamination by Legionella and P. aeruginosa. Legionella was isolated from 36.4%, 24.3% and 53.3% of samples from untreated, periodically and continuously treated waterlines, respectively. The standard microbiological parameters used as indicators of water quality proved to be unreliable as predictors of the presence of Legionella, whose source was identified as the tap water used to supply the dental units. The adoption of control measures, including the use of deionized water in supplying the dental unit waterlines and the application of a combined protocol of continuous and periodic disinfection, with different active products for the different devices, resulted in good control of Legionella contamination. The efficacy of the measures adopted was mainly linked to the strict adherence to the planned protocols, which placed particular stress on staff training and ongoing environmental monitoring.

  10. Atypical presentation of Legionella pneumonia among patients with underlying cancer: A fifteen-year review.

    PubMed

    del Castillo, Maria; Lucca, Anabella; Plodkowski, Andrew; Huang, Yao-Ting; Kaplan, Janice; Gilhuley, Kathleen; Babady, N Esther; Seo, Susan K; Kamboj, Mini

    2016-01-01

    Immunocompromised patients, especially those receiving treatment with corticosteroids and cytotoxic chemotherapy are at increased risk for developing Legionella pneumonia. The aim of this study was to determine clinical and radiographic characteristics of pulmonary infection due to Legionella in persons undergoing treatment for cancer and stem cell transplant (SCT) recipients. Retrospective review of Legionella cases at MSKCC over a fifteen-year study period from January 1999 and December 2013. Cases were identified by review of microbiology records. During the study period, 40 cases of Legionella infection were identified; nine among these were due to non-pneumophila species. Most cases occurred during the summer. The majority [8/9, (89%)] of patients with non-pneumophila infection had underlying hematologic malignancy, compared to 18/31 (58%) with Legionella pneumophila infections. Radiographic findings were varied-nodular infiltrates mimicking invasive fungal infection were seen only among patients with hematologic malignancy and hematopoietic stem cell transplant (SCT) recipients and were frequently associated with non-pneumophila infections (50% vs 16%; P = 0.0594). All cases of nodular Legionella pneumonia were found incidentally or had an indolent clinical course. Legionella should be considered in the differential diagnosis of nodular lung lesions in immunocompromised patients, especially those with hematologic malignancy and SCT recipients. Most cases of nodular disease due to Legionella are associated with non-pneumophila infections. Copyright © 2015 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  11. Ruling out Legionella in community-acquired pneumonia.

    PubMed

    Haubitz, Sebastian; Hitz, Fabienne; Graedel, Lena; Batschwaroff, Marcus; Wiemken, Timothy Lee; Peyrani, Paula; Ramirez, Julio A; Fux, Christoph Andreas; Mueller, Beat; Schuetz, Philipp

    2014-10-01

    Assessing the likelihood for Legionella sp. in community-acquired pneumonia is important because of differences in treatment regimens. Currently used antigen tests and culture have limited sensitivity with important time delays, making empirical broad-spectrum coverage necessary. Therefore, a score with 6 variables recently has been proposed. We sought to validate these parameters in an independent cohort. We analyzed adult patients with community-acquired pneumonia from a large multinational database (Community Acquired Pneumonia Organization) who were treated between 2001 and 2012 with more than 4 of the 6 prespecified clinical variables available. Association and discrimination were assessed using logistic regression analysis and area under the curve (AUC). Of 1939 included patients, the infectious cause was known in 594 (28.9%), including Streptococcus pneumoniae in 264 (13.6%) and Legionella sp. in 37 (1.9%). The proposed clinical predictors fever, cough, hyponatremia, lactate dehydrogenase, C-reactive protein, and platelet count were all associated or tended to be associated with Legionella cause. A logistic regression analysis including all these predictors showed excellent discrimination with an AUC of 0.91 (95% confidence interval, 0.87-0.94). The original dichotomized score showed good discrimination (AUC, 0.73; 95% confidence interval, 0.65-0.81) and a high negative predictive value of 99% for patients with less than 2 parameters present. With the use of a large independent patient sample from an international database, this analysis validates previously proposed clinical variables to accurately rule out Legionella sp., which may help to optimize initial empiric therapy. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. The Surfactant of Legionella pneumophila Is Secreted in a TolC-Dependent Manner and Is Antagonistic toward Other Legionella Species ▿†

    PubMed Central

    Stewart, Catherine R.; Burnside, Denise M.; Cianciotto, Nicholas P.

    2011-01-01

    When Legionella pneumophila grows on agar plates, it secretes a surfactant that promotes flagellum- and pilus-independent “sliding” motility. We isolated three mutants that were defective for surfactant. The first two had mutations in genes predicted to encode cytoplasmic enzymes involved in lipid metabolism. These genes mapped to two adjacent operons that we designated bbcABCDEF and bbcGHIJK. Backcrossing and complementation confirmed the importance of the bbc genes and suggested that the Legionella surfactant is lipid containing. The third mutant had an insertion in tolC. TolC is the outer membrane part of various trimolecular complexes involved in multidrug efflux and type I protein secretion. Complementation of the tolC mutant restored sliding motility. Mutants defective for an inner membrane partner of TolC also lacked a surfactant, confirming that TolC promotes surfactant secretion. L. pneumophila (lspF) mutants lacking type II protein secretion (T2S) are also impaired for a surfactant. When the tolC and lspF mutants were grown next to each other, the lsp mutant secreted surfactant, suggesting that TolC and T2S conjoin to mediate surfactant secretion, with one being the conduit for surfactant export and the other the exporter of a molecule that is required for induction or maturation of surfactant synthesis/secretion. Although the surfactant was not required for the extracellular growth, intracellular infection, and intrapulmonary survival of L. pneumophila, it exhibited antimicrobial activity toward seven other species of Legionella but not toward various non-Legionella species. These data suggest that the surfactant provides L. pneumophila with a selective advantage over other legionellae in the natural environment. PMID:21890700

  13. An international trial of quantitative PCR for monitoring Legionella in artificial water systems.

    PubMed

    Lee, J V; Lai, S; Exner, M; Lenz, J; Gaia, V; Casati, S; Hartemann, P; Lück, C; Pangon, B; Ricci, M L; Scaturro, M; Fontana, S; Sabria, M; Sánchez, I; Assaf, S; Surman-Lee, S

    2011-04-01

      To perform an international trial to derive alert and action levels for the use of quantitative PCR (qPCR) in the monitoring of Legionella to determine the effectiveness of control measures against legionellae.   Laboratories (7) participated from six countries. Legionellae were determined by culture and qPCR methods with comparable detection limits. Systems were monitored over ≥10 weeks. For cooling towers (232 samples), there was a significant difference between the log mean difference between qPCR (GU l(-1) ) and culture (CFU l(-1) ) for Legionella pneumophila (0·71) and for Legionella spp. (2·03). In hot and cold water (506 samples), the differences were less, 0·62 for Leg. pneumophila and 1·05 for Legionella spp. Results for individual systems depended on the nature of the system and its treatment. In cooling towers, Legionella spp. GU l(-1) always exceeded CFU l(-1) , and usually Legionella spp. were detected by qPCR when absent by culture. The pattern of results by qPCR for Leg. pneumophila followed the culture trend. In hot and cold water, culture and qPCR gave similar results, particularly for Leg. pneumophila. There were some marked exceptions with temperatures ≥50°C, or in the presence of supplementary biocides. Action and alert levels for qPCR were derived that gave results comparable to the application of the European Guidelines based on culture. Algorithms are proposed for the use of qPCR for routine monitoring.   Action and alert levels for qPCR can be adjusted to ensure public health is protected with the benefit that remedial actions can be validated earlier with only a small increase in the frequency of action being required.   This study confirms it is possible to derive guidelines on the use of qPCR for monitoring the control of legionellae with consequent improvement to response and public health protection. © 2011 The Authors. Journal of Applied Microbiology © 2011 The Society for Applied Microbiology.

  14. Enumeration of Legionella pneumophila in cooling tower water systems.

    PubMed

    Türetgen, Irfan; Sungur, Esra Ilhan; Cotuk, Aysin

    2005-01-01

    Legionella pneumophila, the causative agent of Legionnaires' disease, is known to colonise and frequently grow in cooling tower waters. Disease is acquired by inhaling aerosol contaminated by legionellae. Determination of the count of Legionella pneumophila in cooling tower waters may, therefore, be useful for risk assessment. In our survey, 103 water samples from 50 cooling towers were examined over a five-year period to indicate the seasonal distribution and the ecology of L. pneumophila, as regards temperature and pH. L. pneumophila serogroup 1 was found in 44% of the isolated strains, which is primarily responsible for the majority of Legionnaires' disease. The large majority of examined towers had levels of L. pneumophila in the high-risk category. These cooling towers have been linked to many outbreaks of Legionnaires' disease.

  15. Induction of iNOS in human monocytes infected with different Legionella species.

    PubMed

    Neumeister, B; Bach, V; Faigle, M; Northoff, H

    2001-08-07

    The contribution of nitric oxide (NO) radicals to the suppression of intracellular replication of Legionella has been well established in rodents but remained questionable in humans. Considering the fact that human monocytes do not exhibit a high-output NO production, we used sensitive methods such as detection of inducible NO synthase (iNOS) mRNA by reverse transcription-PCR and demonstration of iNOS protein expression by means of flow cytometry and Western blot to compare the levels of iNOS induced by Legionella species which, in accordance to their human prevalence, show different multiplication rates within human monocytic cells. The expression of iNOS in Mono Mac 6 (MM6) cells showed an only moderate inverse correlation to the intracellular replication rate of a given Legionella species in the protein expression assays. However, stimulation of host cells with 1,25-dihydroxyvitamin D(3) to enhance NO production and inhibition of NO production by treatment of host cells with N(G)-methyl-L-arginine were not able to modify the intracellular multiplication of legionellae within MM6 cells. Therefore, NO production does not seem to play a crucial role for the restriction of intracellular replication of Legionella bacteria within human monocytic cells. Rodent models in investigations which are supposed to clarify the involvement of NO radicals in defense mechanisms against Legionella infections in humans are of doubtful significance.

  16. Evaluation of timing of re-appearance of VBNC Legionella for risk assessment in hospital water distribution systems.

    PubMed

    Marinelli, L; Cottarelli, A; Solimini, A G; Del Cimmuto, A; De Giusti, M

    2017-01-01

    In this study we estimated the presence of Legionella species, viable but non-culturable (VBNC), in hospital water networks. We also evaluated the time and load of Legionella appearance in samples found negative using the standard culture method. A total of 42 samples was obtained from the tap water of five hospital buildings. The samples were tested for Legionella by the standard culture method and were monitored for up to 12 months for the appearance of VBNC Legionella. All the 42 samples were negative at the time of collection. Seven of the 42 samples (17.0%) became positive for Legionella at different times of monitoring. The time to the appearance of VBNC Legionella was extremely variable, from 15 days to 9 months from sampling. The most frequent Legionella species observed were Legionella spp and L. anisa and only in one sample L. pneumophila srg.1. Our study confirms the presence of VBNC Legionella in samples resulting negative using the standard culture method and highlights the different time to its appearance that can occur several months after sampling. The results are important for risk assessment and risk management of engineered water systems.

  17. In vitro activity of pazufloxacin, tosufloxacin and other quinolones against Legionella species.

    PubMed

    Higa, Futoshi; Akamine, Morikazu; Haranaga, Shusaku; Tohyama, Masato; Shinzato, Takashi; Tateyama, Masao; Koide, Michio; Saito, Atsushi; Fujita, Jiro

    2005-12-01

    The activities of pazufloxacin and tosufloxacin against Legionella spp. were evaluated in vitro and compared with those of other quinolones, macrolides and azithromycin. The conventional MICs were determined by the microbroth dilution method. Intracellular activities of drugs were evaluated by a cfu count. The minimal extracellular concentration inhibiting intracellular growth of bacteria (MIEC) was determined by a colorimetric cytopathic assay. MICs of pazuloxacin and tosufloxacin at which 90% (MIC90) of isolates are inhibited in 76 different Legionella spp. strains (38 ATCC strains and 38 clinical isolates) were 0.032 and 0.016 mg/L, whereas the MIC90s of levofloxacin, ciprofloxacin, garenoxacin, erythromycin, clarithromycin and azithromycin were 0.032, 0.032, 0.032, 2.0, 0.125 and 2.0 mg/L, respectively. Pazufloxacin and tosufloxacin at 4x MIC inhibited intracellular growth of Legionella pneumophila SG1 (80-045 strain), as did other quinolones, clarithromycin and azithromycin, whereas erythromycin at 4x MIC did not. MIECs of pazufloxacin, tosufloxacin, levofloxacin, ciprofloxacin and garenoxacin for the strain were 0.063, 0.004, 0.016, 0.032 and 0.008 mg/L respectively, which were superior to those of macrolides and azithromycin. Pazufloxacin showed potent activity against three additional clinical isolates of L. pneumophila SG1, one clinical isolate each of L. pneumophila SG3 and SG5, as well as Legionella micdadei, Legionella dumoffii and Legionella longbeachae SG1. Pazufloxacin and tosufloxacin, as well as other quinolones, were more potent than macrolides and an azalide. Present data warrant further study on the efficacy of these drugs in the treatment of Legionella infections.

  18. Ecology of Legionella: From Data to Knowledge with a Little Wisdom

    PubMed

    Fliermans

    1996-07-01

    The respiratory diseases produced by the Legionella genus of bacteria are collectively called Legionellosis. Presently more than 34 species of Legionella have been identified, 20 of which have been isolated from both environmental and clinical sources. The diseases produced by Legionella include the pneumonic form, Legionnaires' disease, and the flu-like form, Pontiac fever. Because the vast majority of Legionellosis is caused by the L. pneumophila species, this bacterium is the thrust of the discussion.Legionella is a global bacterium. The relationship of the bacterium to its environment has told us many things about infectious diseases. Not until Legionellosis and the discovery of its etiologic agent, Legionella, has such a successful modern-day marriage been consummated between the agent and its environment. Nearly two decades have passed since the term Legionellosis found its way into the vocabulary of the scientific journals, the popular press, and courtroom proceedings. Too often the scientific development, engineering implementation, and societal acceptance are disconnected. The focus of scientific research sometimes does not reflect engineering or societal needs and thus contributes little to the solution of immediate and important problems. At other times, scientific knowledge that could contribute to solutions is overlooked because of poor communication between the problem holders, the scientific community, regulatory agencies, the problem makers, and the public. The scope of this paper provides insights on the ecological niche of Legionella, describes the organism's ecological relationships in the natural world, and provides wisdom for effective control of the bacterium for the industrial and user communities.

  19. Reduction of Legionella spp. in water and in soil by a citrus plant extract vapor.

    PubMed

    Laird, Katie; Kurzbach, Elena; Score, Jodie; Tejpal, Jyoti; Chi Tangyie, George; Phillips, Carol

    2014-10-01

    Legionnaires' disease is a severe form of pneumonia caused by Legionella spp., organisms often isolated from environmental sources, including soil and water. Legionella spp. are capable of replicating intracellularly within free-living protozoa, and once this has occurred, Legionella is particularly resistant to disinfectants. Citrus essential oil (EO) vapors are effective antimicrobials against a range of microorganisms, with reductions of 5 log cells ml(-1) on a variety of surfaces. The aim of this investigation was to assess the efficacy of a citrus EO vapor against Legionella spp. in water and in soil systems. Reductions of viable cells of Legionella pneumophila, Legionella longbeachae, Legionella bozemanii, and an intra-amoebal culture of Legionella pneumophila (water system only) were assessed in soil and in water after exposure to a citrus EO vapor at concentrations ranging from 3.75 mg/liter air to 15g/liter air. Antimicrobial efficacy via different delivery systems (passive and active sintering of the vapor) was determined in water, and gas chromatography-mass spectrometry (GC-MS) analysis of the antimicrobial components (linalool, citral, and β-pinene) was conducted. There was up to a 5-log cells ml(-1) reduction in Legionella spp. in soil after exposure to the citrus EO vapors (15 mg/liter air). The most susceptible strain in water was L. pneumophila, with a 4-log cells ml(-1) reduction after 24 h via sintering (15 g/liter air). Sintering the vapor through water increased the presence of the antimicrobial components, with a 61% increase of linalool. Therefore, the appropriate method of delivery of an antimicrobial citrus EO vapor may go some way in controlling Legionella spp. from environmental sources. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  20. Isolation of an Amoeba Naturally Harboring a Distinctive Legionella Species

    PubMed Central

    Newsome, Anthony L.; Scott, Tammy M.; Benson, Robert F.; Fields, Barry S.

    1998-01-01

    There are numerous in vitro studies documenting the multiplication of Legionella species in free-living amoebae and other protozoa. It is believed that protozoa serve as host cells for the intracellular replication of certain Legionella species in a variety of environmental settings. This study describes the isolation and characterization of a bacterium initially observed within an amoeba taken from a soil sample. In the laboratory, the bacterium multiplied within and was highly pathogenic for Acanthamoeba polyphaga. Extracellular multiplication was observed on buffered charcoal yeast extract agar but not on a variety of conventional laboratory media. A 16S rRNA gene analysis placed the bacterium within the genus Legionella. Serological studies indicate that it is distinct from previously described species of the genus. This report also describes methods that should prove useful for the isolation and characterization of additional Legionella-like bacteria from free-living amoebae. In addition, the characterization of bacterial pathogens of amoebae has significant implications for understanding the ecology and identification of other unrecognized bacterial pathogens. PMID:9572937

  1. Presence and Persistence of Viable, Clinically Relevant Legionella pneumophila Bacteria in Garden Soil in the Netherlands

    PubMed Central

    van Heijnsbergen, E.; van Deursen, A.; Bouwknegt, M.; Bruin, J. P.; Schalk, J. A. C.

    2016-01-01

    ABSTRACT Garden soils were investigated as reservoirs and potential sources of pathogenic Legionella bacteria. Legionella bacteria were detected in 22 of 177 garden soil samples (12%) by amoebal coculture. Of these 22 Legionella-positive soil samples, seven contained Legionella pneumophila. Several other species were found, including the pathogenic Legionella longbeachae (4 gardens) and Legionella sainthelensi (9 gardens). The L. pneumophila isolates comprised 15 different sequence types (STs), and eight of these STs were previously isolated from patients according to the European Working Group for Legionella Infections (EWGLI) database. Six gardens that were found to be positive for L. pneumophila were resampled after several months, and in three gardens, L. pneumophila was again isolated. One of these gardens was resampled four times throughout the year and was found to be positive for L. pneumophila on all occasions. IMPORTANCE Tracking the source of infection for sporadic cases of Legionnaires' disease (LD) has proven to be hard. L. pneumophila ST47, the sequence type that is most frequently isolated from LD patients in the Netherlands, is rarely found in potential environmental sources. As L. pneumophila ST47 was previously isolated from a garden soil sample during an outbreak investigation, garden soils were investigated as reservoirs and potential sources of pathogenic Legionella bacteria. The detection of viable, clinically relevant Legionella strains indicates that garden soil is a potential source of Legionella bacteria, and future research should assess the public health implication of the presence of L. pneumophila in garden soil. PMID:27316958

  2. Presence and Persistence of Viable, Clinically Relevant Legionella pneumophila Bacteria in Garden Soil in the Netherlands.

    PubMed

    van Heijnsbergen, E; van Deursen, A; Bouwknegt, M; Bruin, J P; de Roda Husman, A M; Schalk, J A C

    2016-09-01

    Garden soils were investigated as reservoirs and potential sources of pathogenic Legionella bacteria. Legionella bacteria were detected in 22 of 177 garden soil samples (12%) by amoebal coculture. Of these 22 Legionella-positive soil samples, seven contained Legionella pneumophila Several other species were found, including the pathogenic Legionella longbeachae (4 gardens) and Legionella sainthelensi (9 gardens). The L. pneumophila isolates comprised 15 different sequence types (STs), and eight of these STs were previously isolated from patients according to the European Working Group for Legionella Infections (EWGLI) database. Six gardens that were found to be positive for L. pneumophila were resampled after several months, and in three gardens, L. pneumophila was again isolated. One of these gardens was resampled four times throughout the year and was found to be positive for L. pneumophila on all occasions. Tracking the source of infection for sporadic cases of Legionnaires' disease (LD) has proven to be hard. L. pneumophila ST47, the sequence type that is most frequently isolated from LD patients in the Netherlands, is rarely found in potential environmental sources. As L. pneumophila ST47 was previously isolated from a garden soil sample during an outbreak investigation, garden soils were investigated as reservoirs and potential sources of pathogenic Legionella bacteria. The detection of viable, clinically relevant Legionella strains indicates that garden soil is a potential source of Legionella bacteria, and future research should assess the public health implication of the presence of L. pneumophila in garden soil. Copyright © 2016 van Heijnsbergen et al.

  3. Genome dynamics in Legionella: the basis of versatility and adaptation to intracellular replication.

    PubMed

    Gomez-Valero, Laura; Buchrieser, Carmen

    2013-06-01

    Legionella pneumophila is a bacterial pathogen present in aquatic environments that can cause a severe pneumonia called Legionnaires' disease. Soon after its recognition, it was shown that Legionella replicates inside amoeba, suggesting that bacteria replicating in environmental protozoa are able to exploit conserved signaling pathways in human phagocytic cells. Comparative, evolutionary, and functional genomics suggests that the Legionella-amoeba interaction has shaped this pathogen more than previously thought. A complex evolutionary scenario involving mobile genetic elements, type IV secretion systems, and horizontal gene transfer among Legionella, amoeba, and other organisms seems to take place. This long-lasting coevolution led to the development of very sophisticated virulence strategies and a high level of temporal and spatial fine-tuning of bacteria host-cell interactions. We will discuss current knowledge of the evolution of virulence of Legionella from a genomics perspective and propose our vision of the emergence of this human pathogen from the environment.

  4. Automobile windshield washer fluid: A potential source of transmission for Legionella.

    PubMed

    Schwake, David Otto; Alum, Absar; Abbaszadegan, Morteza

    2015-09-01

    Epidemiological evidence suggesting driving cars to be a risk factor for legionellosis has prompted public health studies to investigate vehicle windshield washer fluid as a novel transmission source of this disease. The goal of the current study was to investigate whether or not windshield washer fluid could serve as a potential source of transmission for Legionella. A wide variation in the survival of L. pneumophila was observed when incubated in different washer fluids at 25 and 37 °C, however, one brand tested supported Legionella survival similar to or greater than sterilized deionized water. In addition, 1 L of tap water contained in a washer fluid reservoir was able to support population growth and survival of Legionella for several months. In a field study examining the windshield washer fluid of 12 elementary school buses, Legionella were detected from 84% of samples at a high concentration of 8.1×10(4) CFU/mL. Culturable cells were also detected in aerosolized washer fluid during washer fluid spray. By demonstrating survival in certain windshield washer fluids, growth within washer fluid reservoirs, and the presence of viable cells in bus washer fluid spray, we have provided evidence suggesting the potential for a novel route of Legionella exposure. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Exploring the Legionella pneumophila positivity rate in hotel water samples from Antalya, Turkey.

    PubMed

    Sepin Özen, Nevgün; Tuğlu Ataman, Şenay; Emek, Mestan

    2017-05-01

    The genus Legionella is a fastidious Gram-negative bacteria widely distributed in natural waters and man made water supply systems. Legionella pneumophila is the aetiological agent of approximately 90% of reported Legionellosis cases, and serogroup 1 is the most frequent cause of infections. Legionnaires' disease is often associated with travel and continues to be a public health concern at present. The correct water management quality practices and rapid methods for analyzing Legionella species in environmental water is a key point for the prevention of Legionnaires' disease outbreaks. This study aimed to evaluate the positivity rates and serotyping of Legionella species from water samples in the region of Antalya, Turkey, which is an important tourism center. During January-December 2010, a total of 1403 samples of water that were collected from various hotels (n = 56) located in Antalya were investigated for Legionella pneumophila. All samples were screened for L. pneumophila by culture method according to "ISO 11731-2" criteria. The culture positive Legionella strains were serologically identified by latex agglutination test. A total of 142 Legionella pneumophila isolates were recovered from 21 (37.5%) of 56 hotels. The total frequency of L. pneumophila isolation from water samples was found as 10.1%. Serological typing of 142 Legionella isolates by latex agglutination test revealed that strains belonging to L. pneumophila serogroups 2-14 predominated in the examined samples (85%), while strains of L. pneumophila serogroup 1 were less numerous (15%). According to our knowledge, our study with the greatest number of water samples from Turkey demonstrates that L. pneumophila serogroups 2-14 is the most common isolate. Rapid isolation of L. pneumophila from environmental water samples is essential for the investigation of travel related outbreaks and the possible resources. Further studies are needed to have epidemiological data and to determine the types of L

  6. Suspected Legionella-induced perimyocarditis in an adult in the absence of pneumonia: a rare clinical entity.

    PubMed

    Burke, Peter T; Shah, Roshni; Thabolingam, Raveend; Saba, Souheil

    2009-01-01

    Legionella infection can manifest itself in many clinical forms, most commonly as pneumonia, but rarely in the form of myocardial involvement. Legionella with myocardial involvement independent of pneumonia is almost never seen in the adult population and therefore is cited only a handful of times in the medical literature. When reported, Legionella carditis itself typically occurs as an isolated pericarditis with effusion. Cases of isolated Legionella with myocardial involvement, but without associated pneumonia, have been reported among children. To our knowledge, there are no reported cases of Legionella myocarditis and pericarditis presenting concurrently with or without pneumonia, in either an adult or a pediatric population. Herein, we report a rare manifestation of Legionella pneumophila-induced perimyocarditis (strongly suspected, if not incontrovertibly proved) in an adult, in the absence of pneumonia.

  7. Legionella shows a diverse secondary metabolism dependent on a broad spectrum Sfp-type phosphopantetheinyl transferase.

    PubMed

    Tobias, Nicholas J; Ahrendt, Tilman; Schell, Ursula; Miltenberger, Melissa; Hilbi, Hubert; Bode, Helge B

    2016-01-01

    Several members of the genus Legionella cause Legionnaires' disease, a potentially debilitating form of pneumonia. Studies frequently focus on the abundant number of virulence factors present in this genus. However, what is often overlooked is the role of secondary metabolites from Legionella . Following whole genome sequencing, we assembled and annotated the Legionella parisiensis DSM 19216 genome. Together with 14 other members of the Legionella , we performed comparative genomics and analysed the secondary metabolite potential of each strain. We found that Legionella contains a huge variety of biosynthetic gene clusters (BGCs) that are potentially making a significant number of novel natural products with undefined function. Surprisingly, only a single Sfp-like phosphopantetheinyl transferase is found in all Legionella strains analyzed that might be responsible for the activation of all carrier proteins in primary (fatty acid biosynthesis) and secondary metabolism (polyketide and non-ribosomal peptide synthesis). Using conserved active site motifs, we predict some novel compounds that are probably involved in cell-cell communication, differing to known communication systems. We identify several gene clusters, which may represent novel signaling mechanisms and demonstrate the natural product potential of Legionella .

  8. Legionnaires' disease: respiratory infections caused by Legionella bacteria.

    PubMed

    Davis, G S; Winn, W C

    1987-09-01

    This article provides a review of Legionnaire's Disease, a bacterial pneumonia caused by Legionella species, and of Pontiac Fever, the flu-like illness caused by these microorganisms. The authors draw on their personal experience with major human outbreaks of Legionnaire's Disease and with animal models of Legionella pneumonia. Emphasis is placed on the sources in nature from which legionellosis is acquired, the means of dissemination of bacteria, the epidemiology of human infections, the pathogenetic mechanisms of disease and host defense, the clinical manifestations, and the treatment.

  9. Legionella jamestowniensis fatal pneumonia in an immunosuppressed man.

    PubMed

    Edelstein, Paul H

    2017-01-01

    A fatal case of Legionnaires' disease caused by Legionella jamestowniensis is reported in a severely immunocompromised patient with metastatic hepatocellular carcinoma, and liver and kidney transplants. L. jamestowniensis was cultured from two separate respiratory tract specimens and a PCR test for Legionella species was also positive from the same specimens. This is apparently the first reported case of human infection caused by L. jamestowniensis. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  10. Uncovering the Legionella genus effector repertoire - strength in diversity and numbers

    PubMed Central

    Burstein, David; Amaro, Francisco; Zusman, Tal; Lifshitz, Ziv; Cohen, Ofir; Gilbert, Jack A; Pupko, Tal; Shuman, Howard A; Segal, Gil

    2016-01-01

    Infection by the human pathogen Legionella pneumophila relies on the translocation of ~300 virulence proteins, termed effectors, which manipulate host-cell processes. However, almost no information exists regarding effectors in other Legionella pathogens. Here we sequenced, assembled and characterized the genomes of 38 Legionella species, and predicted their effector repertoire using a previously validated machine-learning approach. This analysis revealed a treasure trove of 5,885 predicted effectors. The effector repertoire of different Legionella species was found to be largely non-overlapping, and only seven core-effectors were shared among all species studied. Species-specific effectors had atypically low GC content, suggesting exogenous acquisition, possibly from their natural protozoan hosts. Furthermore, we detected numerous novel conserved effector domains, and discovered new domain combinations, which allowed inferring yet undescribed effector functions. The effector collection and network of domain architectures described here can serve as a roadmap for future studies of effector function and evolution. PMID:26752266

  11. Recreational Vehicle Water Tanks as a Possible Source for Legionella Infections

    PubMed Central

    Litwin, Christine M.; Asebiomo, Bankole; Wilson, Katherine; Hafez, Michael; Stevens, Valerie; Fliermans, Carl B.; Fields, Barry S.; Fisher, John F.

    2013-01-01

    We investigated recreational vehicle (RV) water reservoirs in response to a case of pneumonia in which Legionella pneumophila was cultured both from the patient and a RV reservoir in which he travelled. Water samples processed and cultured at the CDC according to standard protocol were positive for Legionella spp. in 4/17 (24%) faucets, 1/11 (9%) water tanks from 4/20 (20%) RVs from three different campsites. Legionella spp. that were isolated included L. pneumophila (serogroups 1 and 6), L. anisa, L. feeleii, and L. quateriensis. Environmental controls from the potable water of the three campsites were culture-negative. A survey of maintenance practices by the RV users at the campsites revealed that chlorine disinfection of the water tanks was rarely performed. To prevent the possibility of Legionella infections, RV owners should implement regular chlorine disinfection of their water tanks and follow the recommended maintenance guidelines according to their owner's manuals. PMID:24371531

  12. Identification and quantitative detection of Legionella spp. in various aquatic environments by real-time PCR assay.

    PubMed

    Kao, Po-Min; Tung, Min-Che; Hsu, Bing-Mu; Chiu, Yi-Chou; She, Cheng-Yu; Shen, Shu-Min; Huang, Yu-Li; Huang, Wen-Chien

    2013-09-01

    In this study, a SYBR green quantitative real-time PCR was developed to quantify and detect the Legionella spp. in various environmental water samples. The water samples were taken from watershed, water treatment plant, and thermal spring area in Taiwan. Legionella was detected in 13.6 % (24/176), and the detection rate for river water, raw drinking water, and thermal spring water was 10, 21.4, and 16.6 %, respectively. Using real-time PCR, concentration of Legionella spp. in detected samples ranged between 9.75 × 10(4) and 3.47 × 10(5) cells/L in river water, 6.92 × 10(4) and 4.29 × 10(5) cells/L in raw drinking water, and 5.71 × 10(4) and 2.12 × 10(6) cells/L for thermal spring water samples. The identified species included Legionella pneumophila (20.8 %), Legionella jordanis (4.2 %), Legionella nautarum (4.2 %), Legionella sp. (4.2 %), and uncultured Legionella sp. (66.6 %). The presence of L. pneumophila in aquatic environments suggested a potential public health threat that must be further examined.

  13. Usefulness of real-time PCR as a complementary tool to the monitoring of Legionella spp. and Legionella pneumophila by culture in industrial cooling systems.

    PubMed

    Touron-Bodilis, A; Pougnard, C; Frenkiel-Lebossé, H; Hallier-Soulier, S

    2011-08-01

    This study was designed to evaluate the usefulness of quantification by real-time PCR as a management tool to monitor concentrations of Legionella spp. and Legionella pneumophila in industrial cooling systems and its ability to anticipate culture trends by the French standard method (AFNOR T90-431). Quantifications of Legionella bacteria were achieved by both methods on samples from nine cooling systems with different water qualities. Proportion of positive samples for L. pneumophila quantified by PCR was clearly lower in deionized or river waters submitted to a biocide treatment than in raw river waters, while positive samples for Legionella spp. were quantified for almost all the samples. For some samples containing PCR inhibitors, high quantification limits (up to 4·80 × 10(5) GU l(-1) ) did not allow us to quantify L. pneumophila, when they were quantified by culture. Finally, the monitoring of concentrations of L. pneumophila by both methods showed similar trends for 57-100% of the samples. These results suggest that, if some methodological steps designed to reduce inhibitory problems and thus decrease the quantification limits, could be developed to quantify Legionella in complex waters, the real-time PCR could be a valuable complementary tool to monitor the evolution of L. pneumophila concentrations. This study shows the possibility of using real-time PCR to monitor L. pneumophila proliferations in cooling systems and the importance to adapt nucleic acid extraction and purification protocols to raw waters. Journal of Applied Microbiology © 2011 The Society for Applied Microbiology. No claim to French Government works.

  14. Dynamics of genome change among Legionella species

    PubMed Central

    Joseph, Sandeep J.; Cox, Daniel; Wolff, Bernard; Morrison, Shatavia S.; Kozak-Muiznieks, Natalia A.; Frace, Michael; Didelot, Xavier; Castillo-Ramirez, Santiago; Winchell, Jonas; Read, Timothy D.; Dean, Deborah

    2016-01-01

    Legionella species inhabit freshwater and soil ecosystems where they parasitize protozoa. L. pneumonphila (LP) serogroup-1 (Lp1) is the major cause of Legionnaires’ Disease (LD), a life-threatening pulmonary infection that can spread systemically. The increased global frequency of LD caused by Lp and non-Lp species underscores the need to expand our knowledge of evolutionary forces underlying disease pathogenesis. Whole genome analyses of 43 strains, including all known Lp serogroups 1–17 and 17 emergent LD-causing Legionella species (of which 33 were sequenced in this study) in addition to 10 publicly available genomes, resolved the strains into four phylogenetic clades along host virulence demarcations. Clade-specific genes were distinct for genetic exchange and signal-transduction, indicating adaptation to specific cellular and/or environmental niches. CRISPR spacer comparisons hinted at larger pools of accessory DNA sequences in Lp than predicted by the pan-genome analyses. While recombination within Lp was frequent and has been reported previously, population structure analysis identified surprisingly few DNA admixture events between species. In summary, diverse Legionella LD–causing species share a conserved core-genome, are genetically isolated from each other, and selectively acquire genes with potential for enhanced virulence. PMID:27633769

  15. Dynamics of Legionella spp. and bacterial populations during the proliferation of L. pneumophila in a cooling tower facility.

    PubMed

    Wéry, Nathalie; Bru-Adan, Valérie; Minervini, Céline; Delgénes, Jean-Philippe; Garrelly, Laurent; Godon, Jean-Jacques

    2008-05-01

    The dynamics of Legionella spp. and of dominant bacteria were investigated in water from a cooling tower plant over a 9-month period which included several weeks when Legionella pneumophila proliferated. The structural diversity of both the bacteria and the Legionella spp. was monitored by a fingerprint technique, single-strand conformation polymorphism, and Legionella spp. and L. pneumophila were quantified by real-time quantitative PCR. The structure of the bacterial community did not change over time, but it was perturbed periodically by chemical treatment or biofilm detachment. In contrast, the structure of the Legionella sp. population changed in different periods, its dynamics at times showing stability but also a rapid major shift during the proliferation of L. pneumophila in July. The dynamics of the Legionella spp. and of dominant bacteria were not correlated. In particular, no change in the bacterial community structure was observed during the proliferation of L. pneumophila. Legionella spp. present in the cooling tower system were identified by cloning and sequencing of 16S rRNA genes. A high diversity of Legionella spp. was observed before proliferation, including L. lytica, L. fallonii, and other Legionella-like amoebal pathogen types, along with as-yet-undescribed species. During the proliferation of L. pneumophila, Legionella sp. diversity decreased significantly, L. fallonii and L. pneumophila being the main species recovered.

  16. Dynamics of Legionella spp. and Bacterial Populations during the Proliferation of L. pneumophila in a Cooling Tower Facility▿

    PubMed Central

    Wéry, Nathalie; Bru-Adan, Valérie; Minervini, Céline; Delgénes, Jean-Philippe; Garrelly, Laurent; Godon, Jean-Jacques

    2008-01-01

    The dynamics of Legionella spp. and of dominant bacteria were investigated in water from a cooling tower plant over a 9-month period which included several weeks when Legionella pneumophila proliferated. The structural diversity of both the bacteria and the Legionella spp. was monitored by a fingerprint technique, single-strand conformation polymorphism, and Legionella spp. and L. pneumophila were quantified by real-time quantitative PCR. The structure of the bacterial community did not change over time, but it was perturbed periodically by chemical treatment or biofilm detachment. In contrast, the structure of the Legionella sp. population changed in different periods, its dynamics at times showing stability but also a rapid major shift during the proliferation of L. pneumophila in July. The dynamics of the Legionella spp. and of dominant bacteria were not correlated. In particular, no change in the bacterial community structure was observed during the proliferation of L. pneumophila. Legionella spp. present in the cooling tower system were identified by cloning and sequencing of 16S rRNA genes. A high diversity of Legionella spp. was observed before proliferation, including L. lytica, L. fallonii, and other Legionella-like amoebal pathogen types, along with as-yet-undescribed species. During the proliferation of L. pneumophila, Legionella sp. diversity decreased significantly, L. fallonii and L. pneumophila being the main species recovered. PMID:18390683

  17. High Prevalence, Genetic Diversity and Intracellular Growth Ability of Legionella in Hot Spring Environments

    PubMed Central

    Zhou, Haijian; Wang, Huanxin; Xu, Ying; Zhao, Mingqiang; Guan, Hong; Li, Machao; Shao, Zhujun

    2013-01-01

    Background Legionella is the causative agent of Legionnaires' disease, and hot springs are a major source of outbreaks of this disease. It is important from a public health perspective to survey hot spring environments for the presence of Legionella. Methods Prospective surveillance of the extent of Legionella pollution was conducted at three hot spring recreational areas in Beijing, China in 2011. Pulsed-field gel electrophoresis (PFGE) and sequence-based typing (SBT) were used to describe the genetic polymorphism of isolates. The intracellular growth ability of the isolates was determined by interacting with J774 cells and plating the dilutions onto BCYE agar plates. Results Overall, 51.9% of spring water samples showed Legionella-positive, and their concentrations ranged from 1 CFU/liter to 2,218 CFU/liter. The positive rates of Legionella were significantly associated with a free chlorine concentration of ≥0.2 mg/L, urea concentration of ≥0.05 mg/L, total microbial counts of ≥400 CFU/ml and total coliform of ≥3 MPN/L (p<0.01). The Legionella concentrations were significantly associated with sample temperature, pH, total microbial counts and total coliform (p<0.01). Legionella pneumophila was the most frequently isolated species (98.9%), and the isolated serogroups included serogroups 3 (25.3%), 6 (23.4%), 5 (19.2%), 1 (18.5%), 2 (10.2%), 8 (0.4%), 10 (0.8%), 9 (1.9%) and 12 (0.4%). Two hundred and twenty-eight isolates were analyzed by PFGE and 62 different patterns were obtained. Fifty-seven L. pneumophila isolates were selected for SBT analysis and divided into 35 different sequence types with 5 main clonal groups. All the 57 isolates had high intracellular growth ability. Conclusions Our results demonstrated high prevalence and genetic polymorphism of Legionella in springs in Beijing, China, and the SBT and intracellular growth assay results suggested that the Legionella isolates of hot spring environments were pathogenic. Improved control and

  18. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study.

    PubMed

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D'Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-06-22

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis ® μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis ® μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis ® μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis ® μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations.

  19. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study

    PubMed Central

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D’Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-01-01

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis®μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis®μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis®μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis®μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations. PMID:28640202

  20. Effects of culture conditions and biofilm formation on the iodine susceptibility of Legionella pneumophila

    NASA Technical Reports Server (NTRS)

    Cargill, K. L.; Pyle, B. H.; Sauer, R. L.; McFeters, G. A.

    1992-01-01

    The susceptibility of Legionella pneumophila to iodination was studied with cultures grown in well water, on rich agar media, and attached to stainless-steel surfaces. Legionella pneumophila grown in water cultures in association with other microorganisms were less sensitive to disinfection by chlorine and iodine than were agar-passaged cultures. Differences in sensitivity to disinfection between water-cultured and agar-grown legionellae were determined by comparing C x T values (concentration in milligrams per litre multiplied by time in minutes to achieve 99% decrease in viability) and CM x T values (concentration in molarity). Iodine (1500x) gave a greater difference in CM x T values than did chlorine (68x). Iodine was 50 times more effective than chlorine when used with agar-grown cultures but was only twice as effective when tested against water-grown Legionella cultures. C x T x S values (C x T multiplied by percent survivors), which take into consideration the percent surviving bacteria, were used to compare sensitivities in very resistant populations, such as those in biofilms. Water cultures of legionellae associated with stainless-steel surfaces were 135 times more resistant to iodination than were unattached legionellae, and they were 210,000 times more resistant than were agar-grown cultures. These results indicate that the conditions under which legionellae are grown can dramatically affect their susceptibility to some disinfectants and must be considered when evaluating the efficacy of a disinfecting agent.

  1. Diverse protist grazers select for virulence-related traits in Legionella

    PubMed Central

    Amaro, Francisco; Wang, Wen; Gilbert, Jack A; Roger Anderson, O; Shuman, Howard A

    2015-01-01

    It is generally accepted that selection for resistance to grazing by protists has contributed to the evolution of Legionella pneumophila as a pathogen. Grazing resistance is becoming more generally recognized as having an important role in the ecology and evolution of bacterial pathogenesis. However, selection for grazing resistance presupposes the existence of protist grazers that provide the selective pressure. To determine whether there are protists that graze on pathogenic Legionella species, we investigated the existence of such organisms in a variety of environmental samples. We isolated and characterized diverse protists that graze on L. pneumophila and determined the effects of adding L. pneumophila on the protist community structures in microcosms made from these environmental samples. Several unrelated organisms were able to graze efficiently on L. pneumophila. The community structures of all samples were markedly altered by the addition of L. pneumophila. Surprisingly, some of the Legionella grazers were closely related to species that are known hosts for L. pneumophila, indicating the presence of unknown specificity determinants for this interaction. These results provide the first direct support for the hypothesis that protist grazers exert selective pressure on Legionella to acquire and retain adaptations that contribute to survival, and that these properties are relevant to the ability of the bacteria to cause disease in people. We also report a novel mechanism of killing of amoebae by one Legionella species that requires an intact Type IV secretion system but does not involve intracellular replication. We refer to this phenomenon as ‘food poisoning'. PMID:25575308

  2. Extracorporeal membrane oxygenation and severe acute respiratory distress secondary to Legionella: 10 year experience.

    PubMed

    Noah, Moronke A; Ramachandra, Geethanjali; Hickey, Margaret M; Jenkins, David R; Harvey, Chris J; Westrope, Claire A; Firmin, Richard K; Peek, Giles J

    2013-01-01

    Legionella-associated respiratory failure has a high mortality, despite modern ventilation modalities. Extracorporeal membrane oxygenation (ECMO) is used to achieve gas exchange independent of pulmonary function in patients with severe respiratory failure. This was a retrospective review of the management and outcome of patients with Legionella-associated respiratory failure treated with ECMO support in a large ECMO center over the past 10 years. A retrospective review of patients with confirmed Legionella-associated severe respiratory failure managed with ECMO support at a single center. Between 2000 and 2010, 19 patients with severe respiratory failure caused by Legionella were managed with ECMO after failure to respond to conventional intensive care management. Median PaO2/FiO2 ratio was 66 and median pCO2 was 60 torr. Sixteen patients (84%) survived to hospital discharge. Extracorporeal membrane oxygenation should be considered in patients with Legionella-associated respiratory failure, who have failed conventional ventilation.

  3. Comparing methods of determining Legionella spp. in complex water matrices.

    PubMed

    Díaz-Flores, Álvaro; Montero, Juan Carlos; Castro, Francisco Javier; Alejandres, Eva María; Bayón, Carmen; Solís, Inmaculada; Fernández-Lafuente, Roberto; Rodríguez, Guillermo

    2015-04-29

    Legionella testing conducted at environmental laboratories plays an essential role in assessing the risk of disease transmission associated with water systems. However, drawbacks of culture-based methodology used for Legionella enumeration can have great impact on the results and interpretation which together can lead to underestimation of the actual risk. Up to 20% of the samples analysed by these laboratories produced inconclusive results, making effective risk management impossible. Overgrowth of competing microbiota was reported as an important factor for culture failure. For quantitative polymerase chain reaction (qPCR), the interpretation of the results from the environmental samples still remains a challenge. Inhibitors may cause up to 10% of inconclusive results. This study compared a quantitative method based on immunomagnetic separation (IMS method) with culture and qPCR, as a new approach to routine monitoring of Legionella. First, pilot studies evaluated the recovery and detectability of Legionella spp using an IMS method, in the presence of microbiota and biocides. The IMS method results were not affected by microbiota while culture counts were significantly reduced (1.4 log) or negative in the same samples. Damage by biocides of viable Legionella was detected by the IMS method. Secondly, a total of 65 water samples were assayed by all three techniques (culture, qPCR and the IMS method). Of these, 27 (41.5%) were recorded as positive by at least one test. Legionella spp was detected by culture in 7 (25.9%) of the 27 samples. Eighteen (66.7%) of the 27 samples were positive by the IMS method, thirteen of them reporting counts below 10(3) colony forming units per liter (CFU l(-1)), six presented interfering microbiota and three presented PCR inhibition. Of the 65 water samples, 24 presented interfering microbiota by culture and 8 presented partial or complete inhibition of the PCR reaction. So the rate of inconclusive results of culture and PCR was 36

  4. [Contamination of health care institutions environmental objects by Legionella pneumophila].

    PubMed

    Shkarin, V V; Blagonravova, A S; Chubukova, O A; Korotaeva, S V

    2011-01-01

    AIM. The extent of environmental objects contamination by Legionella pneumophila in Nizhny Novgorod and Nizhny Novgorod region hospitals evaluation, and detection of potentially hazardous objects. 433 swabs of environmental objects, and 43 hot water supply and pool water samples from various departments of 4 multi-disciplinary hospitals were studies. DNA from environmental samples was detected by using real time PCR. L. pneumophila DNA was detected in 41 (9,47%) samples from environmental objects and in 2 (4,65%) samples from hot water supply. These bacteria were more frequently detected in environmental samples from physiotherapy departments. Repeated detection of legionellae from the same objects was registered. Circulation of legionellae in multidisciplinary hospitals was determined. Circulation high risk departments and risk objects--reservoirs of L. pneumophila in health care institutions were determined.

  5. TandemHeart as a Bridge to Recovery in Legionella Myocarditis.

    PubMed

    Briceño, David F; Fernando, Rajeev R; Nathan, Sriram; Loyalka, Pranav; Kar, Biswajit; Gregoric, Igor D

    2015-08-01

    Legionnaires' disease is the designation for pneumonia caused by the Legionella species. Among the rare extrapulmonary manifestations, cardiac involvement is most prevalent, in the forms of myocarditis, pericarditis, postcardiotomy syndrome, and prosthetic valve endocarditis. Mechanical circulatory support has proved to be a safe and effective bridge to myocardial recovery in patients with acute fulminant myocarditis; however, to our knowledge, this support has not been used in infectious myocarditis specifically related to Legionellosis. We describe a case of Legionella myocarditis associated with acute left ventricular dysfunction and repolarization abnormalities in a 48-year-old man. The patient fully recovered after left ventricular unloading with use of a TandemHeart percutaneous ventricular assist device. In addition, we review the English-language medical literature on Legionella myocarditis and focus on cardiac outcomes.

  6. [Legionella pneumonia--a case report].

    PubMed

    Marques, A S; Estrada, M H

    2005-01-01

    Legionella, as a cause of community-acquired pneumonia, is probably under-recognized because the diagnosis relies on the use of specific tests as well the existence of an in-numerous species and serogroups not easily identify by the tests available. In studies from Europe and North America, it ranged from 2 to 15 percent of all community-acquired pneumonias that required hospitalisation, in the first four causes when culture methods were done and the second cause of those admitted in the intensive care units. We do a case report of 43 year-old man with history of cigarette smoking and corticosteroid therapy for a ocular disease, that presents with a pneumonia complicated with a Acute Respiratory Distress Syndrome (ARDS), that leaded to his admission to an intensive care unit were he was mechanical ventilated. The epidemiological investigation identified Legionella pneumophila serogroup 1. The authors present this case doing a brief review of this disease and discussing the epidemiology, clinical features, laboratory diagnosis as well as therapeutic options.

  7. Improving the Diagnosis of Legionella Pneumonia within a Healthcare System through a Systematic Consultation and Testing Program.

    PubMed

    Decker, Brooke K; Harris, Patricia L; Muder, Robert R; Hong, Jae H; Singh, Nina; Sonel, Ali F; Clancy, Cornelius J

    2016-08-01

    Legionella testing is not recommended for all patients with pneumonia, but rather for particular patient subgroups. As a result, the overall incidence of Legionella pneumonia may be underestimated. To determine the incidence of Legionella pneumonia in a veteran population in an endemic area after introduction of a systematic infectious diseases consultation and testing program. In response to a 2011-2012 outbreak, the VA Pittsburgh Healthcare System mandated infectious diseases consultations and testing for Legionella by urine antigen and sputum culture in all patients with pneumonia. Between January 2013 and December 2015, 1,579 cases of pneumonia were identified. The incidence of pneumonia was 788/100,000 veterans per year, including 352/100,000 veterans per year and 436/100,000 veterans per year with community-associated pneumonia (CAP) and health care-associated pneumonia, respectively. Ninety-eight percent of patients with suspected pneumonia were tested for Legionella by at least one method. Legionella accounted for 1% of pneumonia cases (n = 16), including 1.7% (12/706) and 0.6% (4/873) of CAP and health care-associated pneumonia, respectively. The yearly incidences of Legionella pneumonia and Legionella CAP were 7.99 and 5.99/100,000 veterans, respectively. The sensitivities of urine antigen and sputum culture were 81% and 60%, respectively; the specificity of urine antigen was >99.97%. Urine antigen testing and Legionella cultures increased by 65% and 330%, respectively, after introduction of our program. Systematic testing of veterans in an endemic area revealed a higher incidence of Legionella pneumonia and CAP than previously reported. Widespread urine antigen testing was not limited by false positivity.

  8. Prevalence study of Legionella spp. contamination in ferries and cruise ships

    PubMed Central

    Azara, Antonio; Piana, Andrea; Sotgiu, Giovanni; Dettori, Marco; Deriu, Maria Grazia; Masia, Maria Dolores; Are, Bianca Maria; Muresu, Elena

    2006-01-01

    Background In the last years, international traffic volume has significantly increased, raising the risk for acquisition of infectious diseases. Among travel-associated infections, increased incidence of legionellosis has been reported among travellers. Aim of our study was: to describe the frequency and severity of Legionella spp. contamination in ferries and cruise ships; to compare the levels of contamination with those indicated by the Italian ministerial guidelines for control and prevention of legionellosis, in order to assess health risks and to adopt control measures. Method A prevalence study was carried out on 9 ships docked at the seaports of northern Sardinia in 2004. Water samples were collected from critical sites: passenger cabins, crew cabins, kitchens, coffee bars, rooms of the central air conditioning system. It was performed a qualitative and quantitative identification of Legionella spp. and a chemical, physical and bacteriological analysis of water samples. Results Forty-two percent (38/90) water samples were contaminated by Legionella spp.. Positive samples were mainly drawn from showers (24/44), washbasins (10/22). L. pneumophila was isolated in 42/44 samples (95.5%), followed by L. micdadei (4.5%). Strains were identified as L. pneumophila serogroup 6 (45.2%; 19 samples), 2–14 (42.9%), 5 (7.1%) and 3 (4.8%). Legionella spp. load was high; 77.8% of the water samples contained > 104 CFU/L. Low residual free chlorine concentration (0–0,2 mg/L) was associated to a contamination of the 50% of the water samples. Conclusion Legionella is an ubiquitous bacterium that could create problems for public health. We identified Legionella spp. in 6/7 ferries. Microbial load was predominantly high (> 104 CFU/L or ranging from 103 to 104 CFU/L). It is matter of concern when passengers are subjects at risk because of Legionella spp. is an opportunist that can survive in freshwater systems; high bacterial load might be an important variable related to

  9. Prevalence study of Legionella spp. contamination in ferries and cruise ships.

    PubMed

    Azara, Antonio; Piana, Andrea; Sotgiu, Giovanni; Dettori, Marco; Deriu, Maria Grazia; Masia, Maria Dolores; Are, Bianca Maria; Muresu, Elena

    2006-04-18

    In the last years, international traffic volume has significantly increased, raising the risk for acquisition of infectious diseases. Among travel-associated infections, increased incidence of legionellosis has been reported among travellers. Aim of our study was: to describe the frequency and severity of Legionella spp. contamination in ferries and cruise ships; to compare the levels of contamination with those indicated by the Italian ministerial guidelines for control and prevention of legionellosis, in order to assess health risks and to adopt control measures. A prevalence study was carried out on 9 ships docked at the seaports of northern Sardinia in 2004. Water samples were collected from critical sites: passenger cabins, crew cabins, kitchens, coffee bars, rooms of the central air conditioning system. It was performed a qualitative and quantitative identification of Legionella spp. and a chemical, physical and bacteriological analysis of water samples. Forty-two percent (38/90) water samples were contaminated by Legionella spp.. Positive samples were mainly drawn from showers (24/44), washbasins (10/22). L. pneumophila was isolated in 42/44 samples (95.5%), followed by L. micdadei (4.5%). Strains were identified as L. pneumophila serogroup 6 (45.2%; 19 samples), 2-14 (42.9%), 5 (7.1%) and 3 (4.8%). Legionella spp. load was high; 77.8% of the water samples contained > 10(4) CFU/L. Low residual free chlorine concentration (0-0.2 mg/L) was associated to a contamination of the 50% of the water samples. Legionella is an ubiquitous bacterium that could create problems for public health. We identified Legionella spp. in 6/7 ferries. Microbial load was predominantly high (> 10(4) CFU/L or ranging from 10(3) to 10(4) CFU/L). It is matter of concern when passengers are subjects at risk because of Legionella spp. is an opportunist that can survive in freshwater systems; high bacterial load might be an important variable related to disease's occurrence. High level of

  10. Legionella feeleii: an unusual organism associated with cutaneous infection in an immunocompromised patient.

    PubMed

    Verykiou, S; Goodhead, C; Parry, G; Meggitt, S

    2018-04-01

    We report a 23-year-old immunocompromised woman who, following cardiac transplantation, presented with an unusual cutaneous eruption. She developed a widespread pustular rash, systemic symptoms and a high temperature with raised inflammatory markers. The diagnosis was reached when a skin biopsy was cultured onto Legionella agar (buffered charcoal yeast extract) and Legionella feeleii was isolated. The patient was treated with 6 weeks of moxifloxacin and her cutaneous lesions gradually resolved. Cutaneous Legionella infections are uncommon and usually affect immunocompromised patients. © 2017 British Association of Dermatologists.

  11. Ciliate Paramecium is a natural reservoir of Legionella pneumophila.

    PubMed

    Watanabe, Kenta; Nakao, Ryo; Fujishima, Masahiro; Tachibana, Masato; Shimizu, Takashi; Watarai, Masahisa

    2016-04-15

    Legionella pneumophila, the causative agent of Legionnaires' disease, replicates within alveolar macrophages and free-living amoebae. However, the lifestyle of L. pneumophila in the environment remains largely unknown. Here we established a novel natural host model of L. pneumophila endosymbiosis using the ciliate Paramecium caudatum. We also identified Legionella endosymbiosis-modulating factor A (LefA), which contributes to the change in life stage from endosymbiosis to host lysis, enabling escape to the environment. We isolated L. pneumophila strains from the environment, and they exhibited cytotoxicity toward P. caudatum and induced host lysis. Acidification of the Legionella-containing vacuole (LCV) was inhibited, and enlarged LCVs including numerous bacteria were observed in P. caudatum infected with L. pneumophila. An isogenic L. pneumophila lefA mutant exhibited decreased cytotoxicity toward P. caudatum and impaired the modification of LCVs, resulting in the establishment of endosymbiosis between them. Our results suggest that L. pneumophila may have a mechanism to switch their endosymbiosis in protistan hosts in the environment.

  12. Ciliate Paramecium is a natural reservoir of Legionella pneumophila

    PubMed Central

    Watanabe, Kenta; Nakao, Ryo; Fujishima, Masahiro; Tachibana, Masato; Shimizu, Takashi; Watarai, Masahisa

    2016-01-01

    Legionella pneumophila, the causative agent of Legionnaires’ disease, replicates within alveolar macrophages and free-living amoebae. However, the lifestyle of L. pneumophila in the environment remains largely unknown. Here we established a novel natural host model of L. pneumophila endosymbiosis using the ciliate Paramecium caudatum. We also identified Legionella endosymbiosis-modulating factor A (LefA), which contributes to the change in life stage from endosymbiosis to host lysis, enabling escape to the environment. We isolated L. pneumophila strains from the environment, and they exhibited cytotoxicity toward P. caudatum and induced host lysis. Acidification of the Legionella-containing vacuole (LCV) was inhibited, and enlarged LCVs including numerous bacteria were observed in P. caudatum infected with L. pneumophila. An isogenic L. pneumophila lefA mutant exhibited decreased cytotoxicity toward P. caudatum and impaired the modification of LCVs, resulting in the establishment of endosymbiosis between them. Our results suggest that L. pneumophila may have a mechanism to switch their endosymbiosis in protistan hosts in the environment. PMID:27079173

  13. Ciliate Paramecium is a natural reservoir of Legionella pneumophila

    NASA Astrophysics Data System (ADS)

    Watanabe, Kenta; Nakao, Ryo; Fujishima, Masahiro; Tachibana, Masato; Shimizu, Takashi; Watarai, Masahisa

    2016-04-01

    Legionella pneumophila, the causative agent of Legionnaires’ disease, replicates within alveolar macrophages and free-living amoebae. However, the lifestyle of L. pneumophila in the environment remains largely unknown. Here we established a novel natural host model of L. pneumophila endosymbiosis using the ciliate Paramecium caudatum. We also identified Legionella endosymbiosis-modulating factor A (LefA), which contributes to the change in life stage from endosymbiosis to host lysis, enabling escape to the environment. We isolated L. pneumophila strains from the environment, and they exhibited cytotoxicity toward P. caudatum and induced host lysis. Acidification of the Legionella-containing vacuole (LCV) was inhibited, and enlarged LCVs including numerous bacteria were observed in P. caudatum infected with L. pneumophila. An isogenic L. pneumophila lefA mutant exhibited decreased cytotoxicity toward P. caudatum and impaired the modification of LCVs, resulting in the establishment of endosymbiosis between them. Our results suggest that L. pneumophila may have a mechanism to switch their endosymbiosis in protistan hosts in the environment.

  14. Fast label-free detection of Legionella spp. in biofilms by applying immunomagnetic beads and Raman spectroscopy.

    PubMed

    Kusić, Dragana; Rösch, Petra; Popp, Jürgen

    2016-03-01

    Legionellae colonize biofilms, can form a biofilm by itself and multiply intracellularly within the protozoa commonly found in water distribution systems. Approximately half of the known species are pathogenic and have been connected to severe multisystem Legionnaires' disease. The detection methods for Legionella spp. in water samples are still based on cultivation, which is time consuming due to the slow growth of this bacterium. Here, we developed a cultivation-independent, label-free and fast detection method for legionellae in a biofilm matrix based on the Raman spectroscopic analysis of isolated single cells via immunomagnetic separation (IMS). A database comprising the Raman spectra of single bacterial cells captured and separated from the biofilms formed by each species was used to build the identification method based on a support vector machine (SVM) discriminative classifier. The complete method allows the detection of Legionella spp. in 100 min. Cross-reactivity of Legionella spp. specific immunomagnetic beads to the other studied genera was tested, where only small cell amounts of Pseudomonas aeruginosa, Klebsiella pneumoniae and Escherichia coli compared to the initial number of cells were isolated by the immunobeads. Nevertheless, the Raman spectra collected from isolated non-targeted bacteria were well-discriminated from the Raman spectra collected from isolated Legionella cells, whereby the Raman spectra of the independent dataset of Legionella strains were assigned with an accuracy of 98.6%. In addition, Raman spectroscopy was also used to differentiate between isolated Legionella species. Copyright © 2016 Elsevier GmbH. All rights reserved.

  15. A New Oligonucleotide Microarray for Detection of Pathogenic and Non-Pathogenic Legionella spp.

    PubMed Central

    Cao, Boyang; Liu, Xiangqian; Yu, Xiang; Chen, Min; Feng, Lu; Wang, Lei

    2014-01-01

    Legionella pneumophila has been recognized as the major cause of legionellosis since the discovery of the deadly disease. Legionella spp. other than L. pneumophila were later found to be responsible to many non-pneumophila infections. The non-L. pneumophila infections are likely under-detected because of a lack of effective diagnosis. In this report, we have sequenced the 16S-23S rRNA gene internal transcribed spacer (ITS) of 10 Legionella species and subspecies, including L. anisa, L. bozemanii, L. dumoffii, L. fairfieldensis, L. gormanii, L. jordanis, L. maceachernii, L. micdadei, L. pneumophila subspp. fraseri and L. pneumophila subspp. pasculleii, and developed a rapid oligonucleotide microarray detection technique accordingly to identify 12 most common Legionella spp., which consist of 11 pathogenic species of L. anisa, L. bozemanii, L. dumoffii, L. gormanii, L. jordanis, L. longbeachae, L. maceachernii, L. micdadei, and L. pneumophila (including subspp. pneumophila, subspp. fraseri, and subspp. pasculleii) and one non-pathogenic species, L. fairfieldensis. Twenty-nine probes that reproducibly detected multiple Legionella species with high specificity were included in the array. A total of 52 strains, including 30 target pathogens and 22 non-target bacteria, were used to verify the oligonucleotide microarray assay. The sensitivity of the detection was at 1.0 ng with genomic DNA or 13 CFU/100 mL with Legionella cultures. The microarray detected seven samples of air conditioner-condensed water with 100% accuracy, validating the technique as a promising method for applications in basic microbiology, clinical diagnosis, food safety, and epidemiological surveillance. The phylogenetic study based on the ITS has also revealed that the non-pathogenic L. fairfieldensis is the closest to L. pneumophila than the nine other pathogenic Legionella spp. PMID:25469776

  16. A new oligonucleotide microarray for detection of pathogenic and non-pathogenic Legionella spp.

    PubMed

    Cao, Boyang; Liu, Xiangqian; Yu, Xiang; Chen, Min; Feng, Lu; Wang, Lei

    2014-01-01

    Legionella pneumophila has been recognized as the major cause of legionellosis since the discovery of the deadly disease. Legionella spp. other than L. pneumophila were later found to be responsible to many non-pneumophila infections. The non-L. pneumophila infections are likely under-detected because of a lack of effective diagnosis. In this report, we have sequenced the 16S-23S rRNA gene internal transcribed spacer (ITS) of 10 Legionella species and subspecies, including L. anisa, L. bozemanii, L. dumoffii, L. fairfieldensis, L. gormanii, L. jordanis, L. maceachernii, L. micdadei, L. pneumophila subspp. fraseri and L. pneumophila subspp. pasculleii, and developed a rapid oligonucleotide microarray detection technique accordingly to identify 12 most common Legionella spp., which consist of 11 pathogenic species of L. anisa, L. bozemanii, L. dumoffii, L. gormanii, L. jordanis, L. longbeachae, L. maceachernii, L. micdadei, and L. pneumophila (including subspp. pneumophila, subspp. fraseri, and subspp. pasculleii) and one non-pathogenic species, L. fairfieldensis. Twenty-nine probes that reproducibly detected multiple Legionella species with high specificity were included in the array. A total of 52 strains, including 30 target pathogens and 22 non-target bacteria, were used to verify the oligonucleotide microarray assay. The sensitivity of the detection was at 1.0 ng with genomic DNA or 13 CFU/100 mL with Legionella cultures. The microarray detected seven samples of air conditioner-condensed water with 100% accuracy, validating the technique as a promising method for applications in basic microbiology, clinical diagnosis, food safety, and epidemiological surveillance. The phylogenetic study based on the ITS has also revealed that the non-pathogenic L. fairfieldensis is the closest to L. pneumophila than the nine other pathogenic Legionella spp.

  17. A distinct and divergent lineage of genomic island-associated Type IV Secretion Systems in Legionella.

    PubMed

    Wee, Bryan A; Woolfit, Megan; Beatson, Scott A; Petty, Nicola K

    2013-01-01

    Legionella encodes multiple classes of Type IV Secretion Systems (T4SSs), including the Dot/Icm protein secretion system that is essential for intracellular multiplication in amoebal and human hosts. Other T4SSs not essential for virulence are thought to facilitate the acquisition of niche-specific adaptation genes including the numerous effector genes that are a hallmark of this genus. Previously, we identified two novel gene clusters in the draft genome of Legionella pneumophila strain 130b that encode homologues of a subtype of T4SS, the genomic island-associated T4SS (GI-T4SS), usually associated with integrative and conjugative elements (ICE). In this study, we performed genomic analyses of 14 homologous GI-T4SS clusters found in eight publicly available Legionella genomes and show that this cluster is unusually well conserved in a region of high plasticity. Phylogenetic analyses show that Legionella GI-T4SSs are substantially divergent from other members of this subtype of T4SS and represent a novel clade of GI-T4SSs only found in this genus. The GI-T4SS was found to be under purifying selection, suggesting it is functional and may play an important role in the evolution and adaptation of Legionella. Like other GI-T4SSs, the Legionella clusters are also associated with ICEs, but lack the typical integration and replication modules of related ICEs. The absence of complete replication and DNA pre-processing modules, together with the presence of Legionella-specific regulatory elements, suggest the Legionella GI-T4SS-associated ICE is unique and may employ novel mechanisms of regulation, maintenance and excision. The Legionella GI-T4SS cluster was found to be associated with several cargo genes, including numerous antibiotic resistance and virulence factors, which may confer a fitness benefit to the organism. The in-silico characterisation of this new T4SS furthers our understanding of the diversity of secretion systems involved in the frequent horizontal gene

  18. A Distinct and Divergent Lineage of Genomic Island-Associated Type IV Secretion Systems in Legionella

    PubMed Central

    Wee, Bryan A.; Woolfit, Megan; Beatson, Scott A.; Petty, Nicola K.

    2013-01-01

    Legionella encodes multiple classes of Type IV Secretion Systems (T4SSs), including the Dot/Icm protein secretion system that is essential for intracellular multiplication in amoebal and human hosts. Other T4SSs not essential for virulence are thought to facilitate the acquisition of niche-specific adaptation genes including the numerous effector genes that are a hallmark of this genus. Previously, we identified two novel gene clusters in the draft genome of Legionella pneumophila strain 130b that encode homologues of a subtype of T4SS, the genomic island-associated T4SS (GI-T4SS), usually associated with integrative and conjugative elements (ICE). In this study, we performed genomic analyses of 14 homologous GI-T4SS clusters found in eight publicly available Legionella genomes and show that this cluster is unusually well conserved in a region of high plasticity. Phylogenetic analyses show that Legionella GI-T4SSs are substantially divergent from other members of this subtype of T4SS and represent a novel clade of GI-T4SSs only found in this genus. The GI-T4SS was found to be under purifying selection, suggesting it is functional and may play an important role in the evolution and adaptation of Legionella. Like other GI-T4SSs, the Legionella clusters are also associated with ICEs, but lack the typical integration and replication modules of related ICEs. The absence of complete replication and DNA pre-processing modules, together with the presence of Legionella-specific regulatory elements, suggest the Legionella GI-T4SS-associated ICE is unique and may employ novel mechanisms of regulation, maintenance and excision. The Legionella GI-T4SS cluster was found to be associated with several cargo genes, including numerous antibiotic resistance and virulence factors, which may confer a fitness benefit to the organism. The in-silico characterisation of this new T4SS furthers our understanding of the diversity of secretion systems involved in the frequent horizontal gene

  19. Prevalence of Legionella strains in cooling towers and legionellosis cases in New Zealand.

    PubMed

    Lau, Robert; Maqsood, Saadia; Harte, David; Caughley, Brian; Deacon, Rob

    2013-01-01

    Over 3,900 water samples from 688 cooling towers were tested for Legionella in 2008 in New Zealand. Of 80 (2.05% isolation rate) Legionella isolates, 10 (12.5%) were L. pneumophila serogroup 1; 10 (12.5%) were L. anisa; nine (11.2%) were L. pneumophila serogroup 8; and one (1.2%) was L. longbeachae serogroup 2. Forty-one (51.2%) Legionella isolates were L. pneumophila serogroups. Over 3,990 water samples from 606 cooling towers were tested for Legionella in 2009 in New Zealand. Of 51 (1.28% isolation rate) Legionella isolates, 18 (35.3%) were L. pneumophila serogroup 1, and 39 (76.4%) were other L. pneumophila serogroups. L. pneumophila serogroups were significantly associated with legionellosis cases in 2008 and 2009. L. longbeachae serogroups were equally significantly associated with legionellosis cases. This significant association of L. longbeachae with legionellosis particularly of L. longbeachae serogroup 1 is unique in that part of the world. The authors' study also showed that the aqueous environment of the cooling tower is not a natural habitat for pathogenic L. longbeachae. Regular monitoring and maintenance of cooling towers have prevented outbreaks of legionellosis.

  20. [Presence of Legionella spp. in household drinking water reservoirs in Resistencia, Chaco, Argentina. Preliminary report].

    PubMed

    Lösch, Liliana S; Merino, Luis A

    Legionella spp. is an environmental bacterium that can survive in a wide range of physicochemical conditions and may colonize distribution systems of drinking water and storage tanks. Legionella pneumophila is the major waterborne pathogen that can cause 90% of Legionnaires' disease cases. The aim of this study was to detect the presence of Legionella spp. in household drinking water tanks in the city of Resistencia, Chaco. The detection of Legionella in water samples was performed by culture methods as set out in ISO 11731:1998. Thirty two water samples were analyzed and Legionella spp. was recovered in 12 (37.5%) of them. The monitoring of this microorganism in drinking water is the first step towards addressing the control of its spread to susceptible hosts. Copyright © 2016 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Legionella species diversity and dynamics from surface reservoir to tap water: from cold adaptation to thermophily

    PubMed Central

    Lesnik, René; Brettar, Ingrid; Höfle, Manfred G

    2016-01-01

    Water samples of the Drinking Water Supply System (DWSS) of the city of Braunschweig were analysed for its Legionella species composition using genus-specific PCR amplicons and single-strand conformation polymorphism (SSCP) fingerprint analyses based on 16S rRNA genes. These analyses comprised the whole supply chain including raw water, treatment process and large-scale storage, and a seasonal study of finished drinking water sampled monthly from cold and hot tap water. Treatment of raw water had a major impact on Legionella species by reducing their diversity and abundances. The Legionella species composition of the tap water was highly distinct from that of both source waters. In cold water, 8–14 different phylotypes of Legionella (PTLs) were observed per sample with relative abundances ranging from >1% to 53%. In hot water, L. pneumophila was present during all seasons at high relative abundances (8–40%) accompanied by 5–14 other PTLs of which 6 PTLs were in common with cold water. This thermophilic Legionella community, including L. pneumophila, was able to grow in the hot water above 50 °C. Such thermophilic Legionella populations are of general relevance for drinking water management and public health, but also for the ecology and evolution of the genus Legionella. PMID:26528838

  2. Legionella species diversity and dynamics from surface reservoir to tap water: from cold adaptation to thermophily.

    PubMed

    Lesnik, René; Brettar, Ingrid; Höfle, Manfred G

    2016-05-01

    Water samples of the Drinking Water Supply System (DWSS) of the city of Braunschweig were analysed for its Legionella species composition using genus-specific PCR amplicons and single-strand conformation polymorphism (SSCP) fingerprint analyses based on 16S rRNA genes. These analyses comprised the whole supply chain including raw water, treatment process and large-scale storage, and a seasonal study of finished drinking water sampled monthly from cold and hot tap water. Treatment of raw water had a major impact on Legionella species by reducing their diversity and abundances. The Legionella species composition of the tap water was highly distinct from that of both source waters. In cold water, 8-14 different phylotypes of Legionella (PTLs) were observed per sample with relative abundances ranging from >1% to 53%. In hot water, L. pneumophila was present during all seasons at high relative abundances (8-40%) accompanied by 5-14 other PTLs of which 6 PTLs were in common with cold water. This thermophilic Legionella community, including L. pneumophila, was able to grow in the hot water above 50 °C. Such thermophilic Legionella populations are of general relevance for drinking water management and public health, but also for the ecology and evolution of the genus Legionella.

  3. Annual variations and effects of temperature on Legionella spp. and other potential opportunistic pathogens in a bathroom.

    PubMed

    Lu, Jingrang; Buse, Helen; Struewing, Ian; Zhao, Amy; Lytle, Darren; Ashbolt, Nicholas

    2017-01-01

    Opportunistic pathogens (OPs) in drinking water, like Legionella spp., mycobacteria, Pseudomonas aeruginosa, and free-living amobae (FLA) are a risk to human health, due to their post-treatment growth in water systems. To assess and manage these risks, it is necessary to understand their variations and environmental conditions for the water routinely used. We sampled premise tap (N cold  = 26, N hot  = 26) and shower (N shower  = 26) waters in a bathroom and compared water temperatures to levels of OPs via qPCR and identified Legionella spp. by 16S ribosomal RNA (rRNA) gene sequencing. The overall occurrence and cell equivalent quantities (CE L -1 ) of Mycobacterium spp. were highest (100 %, 1.4 × 10 5 ), followed by Vermamoeba vermiformis (91 %, 493), Legionella spp. (59 %, 146), P. aeruginosa (14 %, 10), and Acanthamoeba spp. (5 %, 6). There were significant variations of OP's occurrence and quantities, and water temperatures were associated with their variations, especially for Mycobacterium spp., Legionella spp., and V. vermiformis. The peaks observed for Legionella, mainly consisted of Legionella pneumophila sg1 or Legionella anisa, occurred in the temperature ranged from 19 to 49 °C, while Mycobacterium spp. and V. vermiformis not only co-occurred with Legionella spp. but also trended to increase with increasing temperatures. There were higher densities of Mycobacterium in first than second draw water samples, indicating their release from faucet/showerhead biofilm. Legionella spp. were mostly at detectable levels and mainly consisted of L. pneumophila, L. anisa, Legionella donaldsonii, Legionella tunisiensis, and an unknown drinking water isolate based on sequence analysis. Results from this study suggested potential health risks caused by opportunistic pathogens when exposed to warm shower water with low chlorine residue and the use of Mycobacterium spp. as an indicator of premise pipe biofilm and the control management of those potential

  4. Legionella species colonization of water distribution systems, pools and air conditioning systems in cruise ships and ferries

    PubMed Central

    Goutziana, Georgia; Mouchtouri, Varvara A; Karanika, Maria; Kavagias, Antonios; Stathakis, Nikolaos E; Gourgoulianis, Kostantinos; Kremastinou, Jenny; Hadjichristodoulou, Christos

    2008-01-01

    Background Legionnaires' disease continues to be a public health concern in passenger ships. This study was scheduled in order to investigate Legionella spp. colonization of water distribution systems (WDS), recreational pools, and air-conditioning systems on board ferries and cruise ships in an attempt to identify risk factors for Legionella spp. colonization associated with ship water systems and water characteristics. Methods Water systems of 21 ferries and 10 cruise ships including WDS, air conditioning systems and pools were investigated for the presence of Legionella spp. Results The 133 samples collected from the 10 cruise ships WDS, air conditioning systems and pools were negative for Legionella spp. Of the 21 ferries WDS examined, 14 (66.7%) were legionellae-positive. A total of 276 samples were collected from WDS and air conditioning systems. Legionella spp. was isolated from 37.8% of the hot water samples and 17.5% of the cold water samples. Of the total 96 positive isolates, 87 (90.6%) were L. pneumophila. Legionella spp. colonization was positively associated with ship age. The temperature of the hot water samples was negatively associated with colonization of L. pneumophila serogroup (sg) 1 and that of L. pneumophila sg 2 to 14. Increases in pH ≥7.8 and total plate count ≥400 CFU/L, correlated positively with the counts of L. pneumophila sg 2 to 14 and Legionella spp. respectively. Free chlorine of ≥0.2 mg/L inhibited colonization of Legionella spp. Conclusion WDS of ferries can be heavily colonized by Legionella spp. and may present a risk of Legionnaires' disease for passengers and crew members. Guidelines and advising of Legionnaires' disease prevention regarding ferries are needed, in particular for operators and crew members. PMID:19025638

  5. Legionella species colonization of water distribution systems, pools and air conditioning systems in cruise ships and ferries.

    PubMed

    Goutziana, Georgia; Mouchtouri, Varvara A; Karanika, Maria; Kavagias, Antonios; Stathakis, Nikolaos E; Gourgoulianis, Kostantinos; Kremastinou, Jenny; Hadjichristodoulou, Christos

    2008-11-24

    Legionnaires' disease continues to be a public health concern in passenger ships. This study was scheduled in order to investigate Legionella spp. colonization of water distribution systems (WDS), recreational pools, and air-conditioning systems on board ferries and cruise ships in an attempt to identify risk factors for Legionella spp. colonization associated with ship water systems and water characteristics. Water systems of 21 ferries and 10 cruise ships including WDS, air conditioning systems and pools were investigated for the presence of Legionella spp. The 133 samples collected from the 10 cruise ships WDS, air conditioning systems and pools were negative for Legionella spp. Of the 21 ferries WDS examined, 14 (66.7%) were legionellae-positive. A total of 276 samples were collected from WDS and air conditioning systems. Legionella spp. was isolated from 37.8% of the hot water samples and 17.5% of the cold water samples. Of the total 96 positive isolates, 87 (90.6%) were L. pneumophila. Legionella spp. colonization was positively associated with ship age. The temperature of the hot water samples was negatively associated with colonization of L. pneumophila serogroup (sg) 1 and that of L. pneumophila sg 2 to 14. Increases in pH >/=7.8 and total plate count > or =400 CFU/L, correlated positively with the counts of L. pneumophila sg 2 to 14 and Legionella spp. respectively. Free chlorine of > or =0.2 mg/L inhibited colonization of Legionella spp. WDS of ferries can be heavily colonized by Legionella spp. and may present a risk of Legionnaires' disease for passengers and crew members. Guidelines and advising of Legionnaires' disease prevention regarding ferries are needed, in particular for operators and crew members.

  6. The role of biofilms and protozoa in Legionella pathogenesis: implications for drinking water

    EPA Science Inventory

    Current models to study Legionella pathogenesis include the use of primary macrophages and monocyte cell lines, various free-living protozoan species and murine models of pneumonia. However, there are very few studies of Legionella spp. pathogenesis aimed at associating the role ...

  7. Legionella Risk Management and Control in Potable Water Systems: Argument for the Abolishment of Routine Testing

    PubMed Central

    Whiley, Harriet

    2016-01-01

    Legionella is an opportunistic pathogen of public health significance. One of the main sources of Legionella is potable water systems. As a consequence of aging populations there is an increasing demographic considered at high risk for Legionellosis and, as such, a review of the guidelines is required. Worldwide, Legionella has been detected from many potable water sources, suggesting it is ubiquitous in this environment. Previous studies have identified the limitations of the current standard method for Legionella detection and the high possibility of it returning both false negative and false positive results. There is also huge variability in Legionella test results for the same water sample when conducted at different laboratories. However, many guidelines still recommend the testing of water systems. This commentary argues for the removal of routine Legionella monitoring from all water distribution guidelines. This procedure is financially consuming and false negatives may result in managers being over-confident with a system or a control mechanism. Instead, the presence of the pathogen should be assumed and focus spent on managing appropriate control measures and protecting high-risk population groups. PMID:28029126

  8. Legionella Risk Management and Control in Potable Water Systems: Argument for the Abolishment of Routine Testing.

    PubMed

    Whiley, Harriet

    2016-12-24

    Legionella is an opportunistic pathogen of public health significance. One of the main sources of Legionella is potable water systems. As a consequence of aging populations there is an increasing demographic considered at high risk for Legionellosis and, as such, a review of the guidelines is required. Worldwide, Legionella has been detected from many potable water sources, suggesting it is ubiquitous in this environment. Previous studies have identified the limitations of the current standard method for Legionella detection and the high possibility of it returning both false negative and false positive results. There is also huge variability in Legionella test results for the same water sample when conducted at different laboratories. However, many guidelines still recommend the testing of water systems. This commentary argues for the removal of routine Legionella monitoring from all water distribution guidelines. This procedure is financially consuming and false negatives may result in managers being over-confident with a system or a control mechanism. Instead, the presence of the pathogen should be assumed and focus spent on managing appropriate control measures and protecting high-risk population groups.

  9. Influence of climate and geography on the occurrence of Legionella and amoebae in composting facilities.

    PubMed

    Conza, Lisa; Casati Pagani, Simona; Gaia, Valeria

    2014-11-24

    The incidence of Legionnaires' disease (LD) in southern Switzerland is three times higher than in northern Switzerland. Climatic and geographic factors may be potential causes for this difference.We studied the prevalence of Legionella and free-living amoebae (FLA) in compost and bioaerosol in two Swiss regions to understand the role of climate and geography in the transmission of LD. We also tried to investigate whether or not compost storage duration would influence the composition of Legionella and FLA communities. A larger proportion of compost heaps in facilities from southern Switzerland harbor more diverse Legionella compared to the north (P=0.0146). FLA were isolated from composts in northern facilities at slightly higher rates (88.2% vs. 69.2%) and at lower rates from bioaerosols (6.3% vs. 13%) than in southern Switzerland. The diversity of FLA was higher in northern than in southern Switzerland (80% vs. 65%). A general decrease in the presence and variety of species was observed with decreasing compost storage time length. A discriminant model showed that values of vapour pressure, relative humidity and temperature distinguish the two regions, which were also characterised by different contamination rates by FLA and Legionella. The duration of outdoor storage may favour contamination of the compost by Legionella, and may increase the number and isolation of Legionella naturally occurring in compost. The climate in the south seems to favour higher Legionella contamination of compost heaps: this could explain the higher incidence of LD in southern Switzerland.

  10. Industrial Cooling Tower Disinfection Treatment to Prevent Legionella spp.

    PubMed

    Iervolino, Matteo; Mancini, Benedetta; Cristino, Sandra

    2017-09-26

    The contamination of industrial cooling towers has been identified as one cause of legionellosis, but the real risk has been underestimated. Two different disinfection treatments were tested on Legionella colonization in an industrial Cooling Tower System (CTS). Environmental monitoring of Legionella , P. aeruginosa , and a heterotrophic plate count (HPC) at 36 °C was performed from June to October 2016. The disinfection procedures adopted were based on hydrogen peroxide (H₂O₂) and silver salts (Ag⁺), in addition to an anti-algal treatment, then using hyperclorination as a shock, and then continuous treatment by sodium hypochlorite (NaClO). L . pneumophila serogroup 8 was found at a concentration of 5.06 Log cfu/L after the CTS filling; a shock treatment performed by H₂O₂/Ag⁺ produced a rapid increase in contamination up to 6.14 Log cfu/L. The CTS activity was stopped and two subsequent shock treatments were performed using NaClO, followed by continuous hyperclorination. These procedures showed a significant decrease ( p < 0.05) in Legionella concentration (1.77 Log cfu/L). The same trend was observed for P . aeruginosa (0.55 Log cfu/100 mL) and HPC (1.95 Log cfu/mL) at 36 °C. Environmental monitoring and the adoption of maintenance procedures, including anti-scale treatment, and physical, chemical, and microbiological control, ensure the good performance of a CTS, reducing the Legionella risk for public health.

  11. Kinetic analysis of Legionella inactivation using ozone in wastewater.

    PubMed

    Li, Jun; Li, Kunquan; Zhou, Yan; Li, Xuebin; Tao, Tao

    2017-02-01

    Legionella inactivation using ozone was studied in wastewater using kinetic analysis and modeling. The experimental results indicate that the relationship between the ozone concentration, germ concentration, and chemical oxygen demand (COD) can be used to predict variations in germ and COD concentrations. The ozone reaction with COD and inactivation of Legionella occurred simultaneously, but the reaction with COD likely occurred at a higher rate than the inactivation, as COD is more easily oxidized by ozone than Legionella. Higher initial COD concentrations resulted in a lower inactivation rate and higher lnN/N 0 . Higher temperature led to a higher inactivation efficiency. The relationship of the initial O 3 concentration and Legionella inactivation rate was not linear, and thus, the Ct value required for a 99.99% reduction was not constant. The initial O 3 concentration was more important than the contact time, and a reduction of the initial O 3 concentration could not be compensated by increasing the contact time. The Ct values were compared over a narrow range of initial concentrations; the Ct values could only be contrasted when the initial O 3 concentrations were very similar. A higher initial O 3 concentration led to a higher inflection point value for the lnN/N 0 vs C 0 t curve. Energy consumption using a plasma corona was lower than when using boron-doped diamond electrodes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Industrial Cooling Tower Disinfection Treatment to Prevent Legionella spp.

    PubMed Central

    Iervolino, Matteo; Mancini, Benedetta; Cristino, Sandra

    2017-01-01

    The contamination of industrial cooling towers has been identified as one cause of legionellosis, but the real risk has been underestimated. Two different disinfection treatments were tested on Legionella colonization in an industrial Cooling Tower System (CTS). Environmental monitoring of Legionella, P. aeruginosa, and a heterotrophic plate count (HPC) at 36 °C was performed from June to October 2016. The disinfection procedures adopted were based on hydrogen peroxide (H2O2) and silver salts (Ag+), in addition to an anti-algal treatment, then using hyperclorination as a shock, and then continuous treatment by sodium hypochlorite (NaClO). L. pneumophila serogroup 8 was found at a concentration of 5.06 Log cfu/L after the CTS filling; a shock treatment performed by H2O2/Ag+ produced a rapid increase in contamination up to 6.14 Log cfu/L. The CTS activity was stopped and two subsequent shock treatments were performed using NaClO, followed by continuous hyperclorination. These procedures showed a significant decrease (p < 0.05) in Legionella concentration (1.77 Log cfu/L). The same trend was observed for P. aeruginosa (0.55 Log cfu/100 mL) and HPC (1.95 Log cfu/mL) at 36 °C. Environmental monitoring and the adoption of maintenance procedures, including anti-scale treatment, and physical, chemical, and microbiological control, ensure the good performance of a CTS, reducing the Legionella risk for public health. PMID:28954435

  13. Legionella in water samples: how can you interpret the results obtained by quantitative PCR?

    PubMed

    Ditommaso, Savina; Ricciardi, Elisa; Giacomuzzi, Monica; Arauco Rivera, Susan R; Zotti, Carla M

    2015-02-01

    Evaluation of the potential risk associated with Legionella has traditionally been determined from culture-based methods. Quantitative polymerase chain reaction (qPCR) is an alternative tool that offers rapid, sensitive and specific detection of Legionella in environmental water samples. In this study we compare the results obtained by conventional qPCR (iQ-Check™ Quanti Legionella spp.; Bio-Rad) and by culture method on artificial samples prepared in Page's saline by addiction of Legionella pneumophila serogroup 1 (ATCC 33152) and we analyse the selective quantification of viable Legionella cells by the qPCR-PMA method. The amount of Legionella DNA (GU) determined by qPCR was 28-fold higher than the load detected by culture (CFU). Applying the qPCR combined with PMA treatment we obtained a reduction of 98.5% of the qPCR signal from dead cells. We observed a dissimilarity in the ability of PMA to suppress the PCR signal in samples with different amounts of bacteria: the effective elimination of detection signals by PMA depended on the concentration of GU and increasing amounts of cells resulted in higher values of reduction. Using the results from this study we created an algorithm to facilitate the interpretation of viable cell level estimation with qPCR-PMA. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Two nursing home outbreaks of respiratory infection with Legionella sainthelensi.

    PubMed

    Loeb, M; Simor, A E; Mandell, L; Krueger, P; McArthur, M; James, M; Walter, S; Richardson, E; Lingley, M; Stout, J; Stronach, D; McGeer, A

    1999-05-01

    To describe outbreaks of infection caused by Legionella sainthelensi occurring in older residents of two nursing homes and to determine risk factors for the development of infection. Descriptive epidemiology and a case-control study. Two nursing homes (140 beds and 254 beds in nursing homes A and B, respectively) located in southern Ontario, Canada, experiencing outbreaks of respiratory tract infection in July and August 1994. Case-residents of the two nursing homes who met clinical and laboratory criteria for Legionella infection. Control-residents were defined as those who were in the homes during the outbreaks and were asymptomatic. Active surveillance was conducted in both nursing homes to identify symptomatic residents. Residents with fever or respiratory tract symptoms had nasopharyngeal swabs taken for viral antigen detection and culture, urine for Legionella antigen detection, and acute and convalescent serology for viruses, Mycoplasma pneumoniae, Chlamydia pneumoniae, and Legionella. Chest X-rays were performed, and an attempt was made to obtain blood and sputum cultures. Water samples from shower heads, faucets, and air conditioning units were collected for Legionella culture and polymerase chain reaction (PCR) assay. A case-control study was done to assess possible risk factors for legionellosis. Twenty-nine cases -- 17 in nursing home A; 12 in nursing home B - were identified. Four (14%) case-residents had documented pneumonia and four case-residents died. Univariate analysis revealed that a history of stroke (odds ratio (OR) 2.3 (95% CI, 1.0-5.3)), eating pureed food (OR 4.6 (95% CI, 1.6-12.7)), and having fluids administered with medication (OR 2.5 (95% CI, 1.0-5.9)) were significant risk factors. Cases were less likely to wear dentures (OR .4 (95% CI, .2-.9)) or to eat solid food (OR .3, (95% CI, .1-.6)). Only eating pureed food remained significant in a multivariable analysis (OR 4.6 (95% CI, 1.6-13.0, P = .01)). This report describes outbreaks of

  15. Detection of Legionella by cultivation and quantitative real-time polymerase chain reaction in biological waste water treatment plants in Norway.

    PubMed

    Lund, Vidar; Fonahn, Wenche; Pettersen, Jens Erik; Caugant, Dominique A; Ask, Eirik; Nysaeter, Ase

    2014-09-01

    Cases of Legionnaires' disease associated with biological treatment plants (BTPs) have been reported in six countries between 1997 and 2010. However, knowledge about the occurrence of Legionella in BTPs is scarce. Hence, we undertook a qualitative and quantitative screening for Legionella in BTPs treating waste water from municipalities and industries in Norway, to assess the transmission potential of Legionella from these installations. Thirty-three plants from different industries were sampled four times within 1 year. By cultivation, 21 (16%) of 130 analyses were positive for Legionella species and 12 (9%) of 130 analyses were positive for Legionella pneumophila. By quantitative real-time polymerase chain reaction (PCR), 433 (99%) of 437 analyses were positive for Legionella species and 218 (46%) of 470 analyses were positive for L. pneumophila. This survey indicates that PCR could be the preferable method for detection of Legionella in samples from BTPs. Sequence types of L. pneumophila associated with outbreaks in Norway were not identified from the BTPs. We showed that a waste water treatment plant with an aeration basin can produce high concentrations of Legionella. Therefore, these plants should be considered as a possible source of community-acquired Legionella infections.

  16. Environmental Legionella spp. collected in urban test sites of South East Queensland, Australia, are virulent to human macrophages in vitro.

    PubMed

    Lawrence, Amba; Eglezos, Sofroni; Huston, Wilhelmina

    2016-01-01

    Legionellae are frequent contaminants of potable water supplies, resulting in sporadic infections and occasional outbreaks. Isolates of Legionella were collected from urban test sites within South East Queensland and evaluated for their virulence potential in vitro. Two strains (from the species Legionella londiniensis and Legionella quinlivanii) were demonstrated to have the ability to infect human macrophages, while a strain from the species Legionella anisa did not maintain an infection over the same time course. This suggests that the spectrum of urban environmentally associated Legionella with potential to cause human disease might be greater than currently considered. Copyright © 2015 Institut Pasteur. Published by Elsevier Masson SAS. All rights reserved.

  17. MTOR-Driven Metabolic Reprogramming Regulates Legionella pneumophila Intracellular Niche Homeostasis

    PubMed Central

    Abshire, Camille F.; Roy, Craig R.

    2016-01-01

    Vacuolar bacterial pathogens are sheltered within unique membrane-bound organelles that expand over time to support bacterial replication. These compartments sequester bacterial molecules away from host cytosolic immunosurveillance pathways that induce antimicrobial responses. The mechanisms by which the human pulmonary pathogen Legionella pneumophila maintains niche homeostasis are poorly understood. We uncovered that the Legionella-containing vacuole (LCV) required a sustained supply of host lipids during expansion. Lipids shortage resulted in LCV rupture and initiation of a host cell death response, whereas excess of host lipids increased LCVs size and housing capacity. We found that lipids uptake from serum and de novo lipogenesis are distinct redundant supply mechanisms for membrane biogenesis in Legionella-infected macrophages. During infection, the metabolic checkpoint kinase Mechanistic Target of Rapamycin (MTOR) controlled lipogenesis through the Serum Response Element Binding Protein 1 and 2 (SREBP1/2) transcription factors. In Legionella-infected macrophages a host-driven response that required the Toll-like receptors (TLRs) adaptor protein Myeloid differentiation primary response gene 88 (Myd88) dampened MTOR signaling which in turn destabilized LCVs under serum starvation. Inactivation of the host MTOR-suppression pathway revealed that L. pneumophila sustained MTOR signaling throughout its intracellular infection cycle by a process that required the upstream regulator Phosphatidylinositol-4,5-bisphosphate 3-kinase (PI3K) and one or more Dot/Icm effector proteins. Legionella-sustained MTOR signaling facilitated LCV expansion and inhibition of the PI3K-MTOR-SREPB1/2 axis through pharmacological or genetic interference or by activation of the host MTOR-suppression response destabilized expanding LCVs, which in turn triggered cell death of infected macrophages. Our work identified a host metabolic requirement for LCV homeostasis and demonstrated that L

  18. [Legionella spp. contamination in indoor air: preliminary results of an Italian multicenter study].

    PubMed

    Montagna, Maria Teresa; De Giglio, Osvalda; Napoli, Christian; Cannova, Lucia; Cristina, Maria Luisa; Deriu, Maria Grazia; Delia, Santi Antonino; Giuliano, Ada; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Mura, Ida; Pennino, Francesca; Rossini, Angelo; Tardivo, Stefano; Torre, Ida; Torregrossa, Maria Valeria; Villafrate, Maria Rosaria; Albertini, Roberto; Pasquarella, Cesira

    2014-01-01

    To propose a standardized protocol for the evaluation of Legionella contamination in air. A bathroom having a Legionella contamination in water >1,000 cfu/l was selected in 10 different healthcare facilities. Air contamination was assessed by active (Surface Air System, SAS) and passive (Index of Microbial Air, IMA) sampling for 8 hours, about 1 m away from the floor and 50 cm from the tap water. Two hundred liters of air were sampled by SAS every 12 min, after flushing water for 2 min. The IMA value was calculated as the mean value of colony forming units/16 plates exposed during sampling (2 plates/hour). Water contamination was evaluated at T0, after 4 and 8 hours, according to the standard methods. Air contamination by Legionella was found in three healthcare facilities (one with active and two with passive sampling), showing a concomitant tap water contamination (median=40,000; range 1,100-43,000 cfu/l). The remaining seven hospitals isolated Legionella spp. exclusively from water samples (median=8,000; range 1,200-70,000 cfu/l). Our data suggest that environmental Legionella contamination cannot be assessed only through the air sampling, even in the presence of an important water contamination.

  19. Surfactin from Bacillus subtilis displays an unexpected anti-Legionella activity.

    PubMed

    Loiseau, Clémence; Schlusselhuber, Margot; Bigot, Renaud; Bertaux, Joanne; Berjeaud, Jean-Marc; Verdon, Julien

    2015-06-01

    A contaminant bacterial strain was found to exhibit an antagonistic activity against Legionella pneumophila, the causative agent of Legionnaires' disease. The bacterial strain was identified as a Bacillus subtilis and named B. subtilis AM1. PCR analysis revealed the presence of the sfp gene, involved in the biosynthesis of surfactin, a lipopeptide with versatile bioactive properties. The bioactive substances were extracted from AM1 cell-free supernatant with ethyl acetate and purified using reversed phase HPLC (RP-HPLC). Subsequent ESI-MS analyses indicated the presence of two active substances with protonated molecular ions at m/z 1008 and 1036 Da, corresponding to surfactin isoforms. Structures of lipopeptides were further determined by tandem mass spectrometry and compared to the spectra of a commercially available surfactin mixture. Surfactin displays an antibacterial spectrum almost restricted to the Legionella genus (MICs range 1-4 μg/mL) and also exhibits a weak activity toward the amoeba Acanthamoeba castellanii, known to be the natural reservoir of L. pneumophila. Anti-biofilm assays demonstrated that 66 μg/mL of surfactin successfully eliminated 90 % of a 6-day-old biofilm. In conclusion, this study reveals for the first time the potent activity of surfactin against Legionella sp. and preformed biofilms thus providing new directions toward the use and the development of lipopeptides for the control of Legionella spread in the environment.

  20. Real-time PCR to supplement gold-standard culture-based detection of Legionella in environmental samples.

    PubMed

    Collins, S; Jorgensen, F; Willis, C; Walker, J

    2015-10-01

    Culture remains the gold-standard for the enumeration of environmental Legionella. However, it has several drawbacks including long incubation and poor sensitivity, causing delays in response times to outbreaks of Legionnaires' disease. This study aimed to validate real-time PCR assays to quantify Legionella species (ssrA gene), Legionella pneumophila (mip gene) and Leg. pneumophila serogroup-1 (wzm gene) to support culture-based detection in a frontline public health laboratory. Each qPCR assay had 100% specificity, excellent sensitivity (5 GU/reaction) and reproducibility. Comparison of the assays to culture-based enumeration of Legionella from 200 environmental samples showed that they had a negative predictive value of 100%. Thirty eight samples were positive for Legionella species by culture and qPCR. One hundred samples were negative by both methods, whereas 62 samples were negative by culture but positive by qPCR. The average log10 increase between culture and qPCR for Legionella spp. and Leg. pneumophila was 0·72 (P = 0·0002) and 0·51 (P = 0·006), respectively. The qPCR assays can be conducted on the same 1 l water sample as culture thus can be used as a supplementary technique to screen out negative samples and allow more rapid indication of positive samples. The assay could prove informative in public health investigations to identify or rule out sources of Legionella as well as to specifically identify Leg. pneumophila serogroup 1 in a timely manner not possible with culture. © 2015 The Society for Applied Microbiology.

  1. Development of a pilot-scale 1 for Legionella elimination in biofilm in hot water network: heat shock treatment evaluation.

    PubMed

    Farhat, M; Trouilhé, M-C; Briand, E; Moletta-Denat, M; Robine, E; Frère, J

    2010-03-01

    (i) To develop an analytical tool in order to evaluate the effectiveness of anti-Legionella treatment in biofilm and (ii) study the fate of Legionella populations in water and biofilm after applying a heat shock treatment. A pilot-scale unit simulating a hot water system was built and designed by the Scientific and Technical Building Centre (CSTB, France). At the end of the contamination period, a stable cultivable Legionella spp. concentration of 5x10(5) CFU l(-1) was obtained. Two heat shock treatments (70 degrees C for 30 min) were applied. The results showed that the first treatment had a transitional effect on the abatement of Legionella concentrations, while the second treatment had no detectable effect on Legionella populations in water and biofilm. The DAPI (4',6'-diamidino-2-phenylindole), Legionella PCR and GVPC (glycocolle vancomycin pyrophosphate cycloheximide) counts measured in the dead leg water of the Test Loop were 1, 2 and 2 log units higher than results found in the Test Loop water. Moreover, Legionella spp. count in tap water was about 10(4) GU l(-1). These analyses revealed that they are responsible for the rapid recolonization as well as the uncomplete destroyed biofilm. In addition, a resistance test was conducted and showed that Legionella in the second heat shock treatment was not thermo-resistant but thermo-acclimated. Thermal disinfection does not seem to be efficient enough to eliminate Legionella when it is used as a curative treatment. This work could help water managers for a better management of water network and for a better control of Legionella.

  2. Live cell imaging of phosphoinositide dynamics during Legionella infection.

    PubMed

    Weber, Stephen; Hilbi, Hubert

    2014-01-01

    The "accidental" pathogen Legionella pneumophila replicates intracellularly in a distinct compartment, the Legionella-containing vacuole (LCV). To form this specific pathogen vacuole, the bacteria translocate via the Icm/Dot type IV secretion system approximately 300 different effector proteins into the host cell. Several of these secreted effectors anchor to the cytoplasmic face of the LCV membrane by binding to phosphoinositide (PI) lipids. L. pneumophila thus largely controls the localization of secreted bacterial effectors and the recruitment of host factors to the LCV through the modulation of the vacuole membrane PI pattern. The LCV PI pattern and its dynamics can be studied in real-time using fluorescently labeled protein probes stably produced by the soil amoeba Dictyostelium discoideum. In this chapter, we describe a protocol to (1) construct and handle amoeba model systems as a tool for observing PIs in live cell imaging, (2) capture rapid changes in membrane PI patterning during uptake events, and (3) observe the dynamics of LCV PIs over the course of a Legionella infection.

  3. Legionella pneumophila Secretes a Mitochondrial Carrier Protein during Infection

    PubMed Central

    Dolezal, Pavel; Aili, Margareta; Tong, Janette; Jiang, Jhih-Hang; Marobbio, Carlo M.; Lee, Sau fung; Schuelein, Ralf; Belluzzo, Simon; Binova, Eva; Mousnier, Aurelie; Frankel, Gad; Giannuzzi, Giulia; Palmieri, Ferdinando; Gabriel, Kipros; Naderer, Thomas; Hartland, Elizabeth L.; Lithgow, Trevor

    2012-01-01

    The Mitochondrial Carrier Family (MCF) is a signature group of integral membrane proteins that transport metabolites across the mitochondrial inner membrane in eukaryotes. MCF proteins are characterized by six transmembrane segments that assemble to form a highly-selective channel for metabolite transport. We discovered a novel MCF member, termed Legionella nucleotide carrier Protein (LncP), encoded in the genome of Legionella pneumophila, the causative agent of Legionnaire's disease. LncP was secreted via the bacterial Dot/Icm type IV secretion system into macrophages and assembled in the mitochondrial inner membrane. In a yeast cellular system, LncP induced a dominant-negative phenotype that was rescued by deleting an endogenous ATP carrier. Substrate transport studies on purified LncP reconstituted in liposomes revealed that it catalyzes unidirectional transport and exchange of ATP transport across membranes, thereby supporting a role for LncP as an ATP transporter. A hidden Markov model revealed further MCF proteins in the intracellular pathogens, Legionella longbeachae and Neorickettsia sennetsu, thereby challenging the notion that MCF proteins exist exclusively in eukaryotic organisms. PMID:22241989

  4. A rapid detection method using flow cytometry to monitor the risk of Legionella in bath water.

    PubMed

    Taguri, Toshitsugu; Oda, Yasunori; Sugiyama, Kanji; Nishikawa, Toru; Endo, Takuro; Izumiyama, Shinji; Yamazaki, Masayuki; Kura, Fumiaki

    2011-07-01

    Legionella species are the causative agents of human legionellosis, and bathing facilities have been identified as the sources of infection in several outbreaks in Japan. Researchers in Japan have recently reported evidence of significant associations between bacterial counts and the occurrence of Legionella in bathing facilities and in a hot tub model. A convenient and quantitative bacterial enumeration method is therefore required as an indicator of Legionella contamination or disinfection to replace existing methods such as time-consuming Legionella culture and expensive Legionella-DNA amplification. In this study, we developed a rapid detection method (RDM) to monitor the risk of Legionella using an automated microbial analyzing device based on flow cytometry techniques to measure the total number of bacteria in water samples within two minutes, by detecting typical patterns of scattered light and fluorescence. We first compared the results of our RDM with plate counting results for five filtered hot spring water samples spiked with three species of bacteria, including Legionella. Inactivation of these samples by chlorine was also assessed by the RDM, a live/dead bacterial fluorescence assay and plate counting. Using the RDM, the lower limit of quantitative bacterial counts in the spiked samples was determined as 3.0×10(3)(3.48log)counts mL(-1). We then used a laboratory model of a hot tub and found that the RDM could monitor the growth curve of naturally occurring heterotrophic bacteria with 1 and 2 days' delayed growth of amoeba and Legionella, respectively, and could also determine the killing curve of these bacteria by chlorination. Finally, samples with ≥3.48 or <3.48log total bacterial counts mL(-1) were tested using the RDM from 149 different hot tubs, and were found to be significantly associated with the positive or negative detection of Legionella with 95% sensitivity and 84% specificity. These findings indicated that the RDM can be used for

  5. Genome Dynamics in Legionella: The Basis of Versatility and Adaptation to Intracellular Replication

    PubMed Central

    Gomez-Valero, Laura; Buchrieser, Carmen

    2013-01-01

    Legionella pneumophila is a bacterial pathogen present in aquatic environments that can cause a severe pneumonia called Legionnaires’ disease. Soon after its recognition, it was shown that Legionella replicates inside amoeba, suggesting that bacteria replicating in environmental protozoa are able to exploit conserved signaling pathways in human phagocytic cells. Comparative, evolutionary, and functional genomics suggests that the Legionella–amoeba interaction has shaped this pathogen more than previously thought. A complex evolutionary scenario involving mobile genetic elements, type IV secretion systems, and horizontal gene transfer among Legionella, amoeba, and other organisms seems to take place. This long-lasting coevolution led to the development of very sophisticated virulence strategies and a high level of temporal and spatial fine-tuning of bacteria host–cell interactions. We will discuss current knowledge of the evolution of virulence of Legionella from a genomics perspective and propose our vision of the emergence of this human pathogen from the environment. PMID:23732852

  6. Occurrence and parameters of frequency of Legionella in warm water systems of hospitals and hotels in Lower Saxony.

    PubMed

    Habicht, W; Müller, H E

    1988-03-01

    A total of 1241 water samples was investigated from 103 hospitals and 62 hotels in Lower Saxony 1985-87. 331 of 949 samples from hospitals and 26 of 292 samples from hotels were Legionella positive. All together 70% of the hospitals and 18% of the hotels investigated were Legionella positive, and 836 strains of Legionella were isolated (Table 1). As they could be diagnosed they belong to L. pneumophila SG1 306 strains, SG2 36 strains, SG3 127 strains, SG4 45 strain, SG5 29 strain, SG6 106 strains, SG9 13 strains and SG10 13 strains. Further 134 strains belonging to L. pneumophila but not to SG1-SG12 show cross reactions with serogroups 5, 8, and 10. Finally, 16 strains belong to L. dumoffii and 1 strain to L. anisa (Table 2). The following parameters of water samples were studied, too: temperature, pH value, conductivity, concentration of iron, of organic matter, of other bacteria, occurrence of amoebas, and the materials of water plumbing systems. Most samples contained concentrations of Legionella in the range of 10(1)-10(3) CFU/ml, highest concentrations were 10(5) CFU/ml (Fig. 1). Most frequently, Legionella were isolated within the range of temperature of 35-45 degrees C. However, a few of the water samples were positive for Legionella even up to 66 degrees C (Fig. 3). The conductivity has no and the pH value (Fig. 2) has only little influence on the occurrence of Legionella. There is a positive correlation between concentration of iron and frequency of Legionella (Fig. 4). Also organic matter (Fig. 6) and amoebas (Table 3) seem to enhance the occurrence of Legionella. Plumbing systems consisting of copper showed an inhibitory effect on Legionella during the first five years, whereas no effect could be detected in older systems (Fig. 5).

  7. Application of Hydrogen Peroxide as an Innovative Method of Treatment for Legionella Control in a Hospital Water Network.

    PubMed

    Casini, Beatrice; Aquino, Francesco; Totaro, Michele; Miccoli, Mario; Galli, Irio; Manfredini, Laura; Giustarini, Carlo; Costa, Anna Laura; Tuvo, Benedetta; Valentini, Paola; Privitera, Gaetano; Baggiani, Angelo

    2017-04-17

    To evaluate the effectiveness of hydrogen peroxide (HP) use as a disinfectant in the hospital water network for the control of Legionella spp. colonization. Following the detection of high levels of Legionella contamination in a 136-bed general hospital water network, an HP treatment of the hot water supply (25 mg/L) was adopted. During a period of 34 months, the effectiveness of HP on Legionella colonization was assessed. Legionella was isolated in accordance with ISO-11731 and identification was carried out by sequencing of the mip gene. Before HP treatment, L. pneumophila sg 2-15 was isolated in all sites with a mean count of 9950 ± 8279 cfu/L. After one-month of HP treatment, we observed the disappearance of L. pneumophila 2-15, however other Legionella species previously not seen were found; Legionella pneumophila 1 was isolated in one out of four sampling sites (2000 cfu/L) and other non- pneumophila species were present in all sites (mean load 3000 ± 2887 cfu/L). Starting from September 2013, HP treatment was modified by adding food-grade polyphosphates, and in the following months, we observed a progressive reduction of the mean load of all species ( p < 0.05), resulting in substantial disappearance of Legionella colonization. Hydrogen peroxide demonstrated good efficacy in controlling Legionella . Although in the initial phases of treatment it appeared unable to eliminate all Legionella species, by maintaining HP levels at 25 mg/L and adding food-grade polyphosphates, a progressive and complete control of colonization was obtained.

  8. Severe Pneumonia Caused by Legionella pneumophila: Differential Diagnosis and Therapeutic Considerations.

    PubMed

    Chahin, Abdullah; Opal, Steven M

    2017-03-01

    Severe legionella pneumonia poses a diagnostic challenge and requires early intervention. Legionnaire's disease can have several presenting signs, symptoms, and laboratory abnormalities that suggest that Legionella pneumophila is the pathogen, but none of these are sufficient to distinguish L pneumophila pneumonia from other respiratory pathogens. L pneumophila is primarily an intracellular pathogen and needs treatment with antibiotics that efficiently enter the intracellular space. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Molecular diagnosis of Legionella infections--Clinical utility of front-line screening as part of a pneumonia diagnostic algorithm.

    PubMed

    Gadsby, Naomi J; Helgason, Kristjan O; Dickson, Elizabeth M; Mills, Jonathan M; Lindsay, Diane S J; Edwards, Giles F; Hanson, Mary F; Templeton, Kate E

    2016-02-01

    Urinary antigen testing for Legionella pneumophila serogroup 1 is the leading rapid diagnostic test for Legionnaires' Disease (LD); however other Legionella species and serogroups can also cause LD. The aim was to determine the utility of front-line L. pneumophila and Legionella species PCR in a severe respiratory infection algorithm. L. pneumophila and Legionella species duplex real-time PCR was carried out on 1944 specimens from hospitalised patients over a 4 year period in Edinburgh, UK. L. pneumophila was detected by PCR in 49 (2.7%) specimens from 36 patients. During a LD outbreak, combined L. pneumophila respiratory PCR and urinary antigen testing had optimal sensitivity and specificity (92.6% and 98.3% respectively) for the detection of confirmed cases. Legionella species was detected by PCR in 16 (0.9%) specimens from 10 patients. The 5 confirmed and 1 probable cases of Legionella longbeachae LD were both PCR and antibody positive. Front-line L. pneumophila and Legionella species PCR is a valuable addition to urinary antigen testing as part of a well-defined algorithm. Cases of LD due to L. longbeachae might be considered laboratory-confirmed when there is a positive Legionella species PCR result and detection of L. longbeachae specific antibody response. Copyright © 2015 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  10. Environmental surveillance and molecular investigation of Legionella spp. in Apulia, in the years 2008-2011.

    PubMed

    Iatta, R; Cuna, T; Napoli, C; De Giglio, O; Montagna, M T

    2013-01-01

    Legionella spp. is considered an emerging microorganism involved in aquatic environments contamination and cause of Legionnaires' disease. The aims of the study are to evaluate the level of contamination of Legionella spp. in the water system of the largest Hospital of Apulia region during a 4-year surveillance and to establish, by molecular method, the presence of a predominant genotype of L. pn. sg 1. The results showed that Legionella spp. was present in 36% of water samples with Legionella pneumophila serogroup 1 (L. pn. sg 1) the most prevalent species and serogroup and the wards most contaminated are the high risk units. In addition, despite four main clones of L. pn. sg 1 were identified, a predominant genotype existed. In conclusion the study demonstrates the necessity for periodic evaluation on hospitals water system to assess the potential contamination of Legionella spp., performing decontamination in the presence of bacterial contamination, even low, in particular in high risk wards. Moreover, the switching of the disinfection methods may be suggested in order to prevent resistance phenomenon by some L. pn. sg 1 clones.

  11. Legionella species in year-round vs. seasonal accommodation water supply systems.

    PubMed

    Rakić, Anita; Perić, Jelena; Štambuk-Giljanović, Nives; Mikrut, Antonija; Bakavić, Ana-Spomenka

    2011-12-01

    The purpose of this study was to compare the quality of hot water between eleven hotels in the Split-Dalmatia County, Croatia that are open year round and 10 summer season hotels and retirement homes with irregular use of water. We took 122 samples between May and December 2009. Water temperature and free residual chlorine were measured in situ. Physical and chemical analysis included pH, electrical conductivity, and concentrations of iron, manganese, copper, zinc, calcium, and magnesium that were measured using atomic absorption spectrophotometry, while the Legionella species were determined using a cultivation method on buffered charcoal yeast extract agar. Differences in metal concentrations between the seasonal and year-round accommodation facilities were negligible, save for zinc that was higher in year-round (0.341 mg L(-1)) than in seasonal facilities (0.130 mg L(-1)). Samples from all year-round and six summer season hotels were negative to the Legionella species, but four seasonal facilities turned up with positive samples to Legionella pneumophila. Our study has demonstrated that water quality differs between year-round and seasonal accommodation facilities. These findings suggest that metal plumbing components and associated corrosion products are important factors in the survival and growth of Legionella species in water distribution systems.

  12. Chemotaxonomic differentiation of legionellae by detection and characterization of aminodideoxyhexoses and other unique sugars using gas chromatography-mass spectrometry.

    PubMed Central

    Fox, A; Rogers, J C; Fox, K F; Schnitzer, G; Morgan, S L; Brown, A; Aono, R

    1990-01-01

    Legionellae have been differentiated previously by analyzing their carbohydrate contents by gas chromatography with flame ionization detection. In the present study, total ion mode gas chromatography-mass spectrometry (GC-MS) was used to detect a number of unusual sugars, including one that is structurally related to O-methyldideoxyheptoses. Increased sensitivity and selectivity for carbohydrate detection was achieved by selected ion-monitoring GC-MS. Two of the uncommon sugars previously discovered in the legionellae (X1 and X2) were identified as quinovosamine and fucosamine, respectively. Legionella pneumophila contained rhamnose and quinovosamine but not the quinovosamine isomer fucosamine. Tatlockia micdadei and Legionella maceachernii contained large amounts of rhamnose, fucose, and fucosamine but not quinovosamine. These two species were the only legionellae studied that contained another unusual sugar that is referred to as X3, pending determination of its structure. Fluoribacter dumoffi, Fluoribacter bozemanae, and Legionella anisa were varied in their carbohydrate contents, both within and between species, but could be distinguished from L. pneumophila and the T. micdadei and L. maceachernii group. Fluoribacter gormanii was unique among the legionellae in that it lacked both quinovosamine and fucosamine. Legionella jordanis contained other unusual carbohydrates in addition to quinovosamine. GC-MS may have wide application in the differentiation of bacterial species. PMID:2324276

  13. Improved PCR assay for the species-specific identification and quantitation of Legionella pneumophila in water.

    PubMed

    Cho, Min Seok; Ahn, Tae-Young; Joh, Kiseong; Lee, Eui Seok; Park, Dong Suk

    2015-11-01

    Legionellosis outbreak is a major global health care problem. However, current Legionella risk assessments may be compromised by uncertainties in Legionella detection methods, infectious dose, and strain infectivity. These limitations may place public health at significant risk, leading to significant monetary losses in health care. However, there are still unmet needs for its rapid identification and monitoring of legionellae in water systems. Therefore, in the present study, a primer set was designed based on a LysR-type transcriptional regulator (LTTR) family protein gene of Legionella pneumophila subsp. pneumophila str. Philadelphia 1 because it was found that this gene is structurally diverse among species through BLAST searches. The specificity of the primer set was evaluated using genomic DNA from 6 strains of L. pneumophila, 5 type strains of other related Legionella species, and other 29 reference pathogenic bacteria. The primer set used in the PCR assay amplified a 264-bp product for only targeted six strains of L. pneumophila. The assay was also able to detect at least 1.39 × 10(3) copies/μl of cloned amplified target DNA using purified DNA or 7.4 × 10(0) colony-forming unit per reaction when using calibrated cell suspension. In addition, the sensitivity and specificity of this assay were confirmed by successful detection of Legionella pneumophila in environmental water samples.

  14. Legionella thermalis sp. nov., isolated from hot spring water in Tokyo, Japan.

    PubMed

    Ishizaki, Naoto; Sogawa, Kazuyuki; Inoue, Hiroaki; Agata, Kunio; Edagawa, Akiko; Miyamoto, Hiroshi; Fukuyama, Masafumi; Furuhata, Katsunori

    2016-03-01

    Strain L-47(T) of a novel bacterial species belonging to the genus Legionella was isolated from a sample of hot spring water from Tokyo, Japan. The 16S rRNA gene sequences (1477 bp) of this strain (accession number AB899895) had less than 95.0% identity with other Legionella species. The dominant fatty acids of strain L-47(T) were a15:0 (29.6%) and the major ubiquinone was Q-12 (71.1%). It had a guanine-plus-cytosine content of 41.5 mol%. The taxonomic description of Legionella thermalis sp. nov. is proposed to be type strain L-47(T) (JCM 30970(T)  = KCTC 42799(T)). © 2016 The Societies and John Wiley & Sons Australia, Ltd.

  15. Characterization of aerosols containing Legionella generated upon nebulization

    NASA Astrophysics Data System (ADS)

    Allegra, Séverine; Leclerc, Lara; Massard, Pierre André; Girardot, Françoise; Riffard, Serge; Pourchez, Jérémie

    2016-09-01

    Legionella pneumophila is, by far, the species most frequently associated with Legionnaires’ disease (LD). Human infection occurs almost exclusively by aerosol inhalation which places the bacteria in juxtaposition with alveolar macrophages. LD risk management is based on controlling water quality by applying standardized procedures. However, to gain a better understanding of the real risk of exposure, there is a need (i) to investigate under which conditions Legionella may be aerosolized and (ii) to quantify bacterial deposition into the respiratory tract upon nebulization. In this study, we used an original experimental set-up that enables the generation of aerosol particles containing L. pneumophila under various conditions. Using flow cytometry in combination with qPCR and culture, we determined (i) the size of the aerosols and (ii) the concentration of viable Legionella forms that may reach the thoracic region. We determined that the 0.26-2.5 μm aerosol size range represents 7% of initial bacterial suspension. Among the viable forms, 0.7% of initial viable bacterial suspension may reach the pulmonary alveoli. In conclusion, these deposition profiles can be used to standardize the size of inoculum injected in any type of respiratory tract model to obtain new insights into the dose response for LD.

  16. Molecular pathogenesis of infections caused by Legionella pneumophila.

    PubMed

    Newton, Hayley J; Ang, Desmond K Y; van Driel, Ian R; Hartland, Elizabeth L

    2010-04-01

    The genus Legionella contains more than 50 species, of which at least 24 have been associated with human infection. The best-characterized member of the genus, Legionella pneumophila, is the major causative agent of Legionnaires' disease, a severe form of acute pneumonia. L. pneumophila is an intracellular pathogen, and as part of its pathogenesis, the bacteria avoid phagolysosome fusion and replicate within alveolar macrophages and epithelial cells in a vacuole that exhibits many characteristics of the endoplasmic reticulum (ER). The formation of the unusual L. pneumophila vacuole is a feature of its interaction with the host, yet the mechanisms by which the bacteria avoid classical endosome fusion and recruit markers of the ER are incompletely understood. Here we review the factors that contribute to the ability of L. pneumophila to infect and replicate in human cells and amoebae with an emphasis on proteins that are secreted by the bacteria into the Legionella vacuole and/or the host cell. Many of these factors undermine eukaryotic trafficking and signaling pathways by acting as functional and, in some cases, structural mimics of eukaryotic proteins. We discuss the consequences of this mimicry for the biology of the infected cell and also for immune responses to L. pneumophila infection.

  17. Occurrence of Legionella in showers at recreational facilities.

    PubMed

    De Filippis, Patrizia; Mozzetti, Cinzia; Amicosante, Massimo; D'Alò, Gian Loreto; Messina, Alessandra; Varrenti, Donatella; Giammattei, Roberto; Di Giorgio, Floriana; Corradi, Stefania; D'Auria, Alberto; Fraietta, Roberta; Gabrieli, Rosanna

    2017-06-01

    Critical environments, including water systems in recreational settings, represent an important source of Legionella pneumophila infection in humans. In order to assess the potential risk for legionellosis, we analyzed Legionella contamination of water distribution systems in 36 recreational facilities equipped with swimming pools. One hundred and sixty water samples were analyzed from shower heads or taps located in locker rooms or in bathrooms. By culture method and polymerase chain reaction, 41/160 samples were positive for Legionella from 12/36 recreational centers. Hotels (57.1%) and sports centers (41.2%) were the most contaminated. L. pneumophila serotypes 2-14 (25/41) were more frequently found than serotype 1 (10/41). Samples at temperature ≥30 °C were more frequently positive than samples at temperature <30 °C (n = 39 vs n = 2, p < 0.00001). The presence of L. pneumophila was investigated by comparison with heterotrophic plate count (HPC), an indicator of water quality. The presence of L. pneumophila was associated more frequently with high and intermediate HPC load at 37 °C, therefore should be considered a potential source when HPC at 37 °C is >10 CFU/mL. Maintenance, good hygiene practices, interventions on the hydraulic system and regular controls must be implemented to minimize exposure to L. pneumophila infection risk.

  18. Detection of Legionella by quantitative-polymerase chain reaction (qPCR) for monitoring and risk assessment.

    PubMed

    Krøjgaard, Louise H; Krogfelt, Karen A; Albrechtsen, Hans-Jørgen; Uldum, Søren A

    2011-11-21

    Culture and quantitative polymerase chain reaction (qPCR) assays for the detection of Legionella were compared on samples from a residential area before and after two interventions. A total of 84 samples were collected from shower hoses and taps as first flush samples and at constant temperature. Samples were grouped according to the origin of the sample, a) circulation water b) water from empty apartments c) water from shower hoses. The aims were to investigate the usefulness of qPCR compared to culture for monitoring remedial actions for elimination of Legionella bacteria and as a tool for risk assessment. In water collected from the apartments Legionella spp were detected by qPCR in the concentration range from LOQ to 9.6*105GU/L while L. pneumophila were detected in a range from LOQ to 6.8*105 GU/L. By culturing, the legionellae were detected in the range from below detection limit (> 10 CFU/L) to 1.6*106 CFU/L. In circulating water and in first flush water from shower hoses, culture and qPCR showed the same tendencies. The overall correlation between the bacteria number detected by culture and the two developed qPCR assays (L. spp and L. pneumophila) was relatively poor (r2 = 0.31 for culture and Legionella spp. assay, r2 = 0.20 for culture and L. pneumophila assay). Detection by qPCR was suitable for monitoring changes in the concentration of Legionella but the precise determination of bacteria is difficult. Risk assessment by qPCR only on samples without any background information regarding treatment, timing, etc is dubious. However, the rapid detection by qPCR of high concentrations of Legionella - especially Legionella pneumophila - is valuable as an indicator of risk, although it may be false positive compared to culture results. On the other hand, the detection of a low number of bacteria by qPCR is a strong indication for the absence of risk.

  19. Legionella confirmation in cooling tower water. Comparison of culture, real-time PCR and next generation sequencing.

    PubMed

    Farhat, Maha; Shaheed, Raja A; Al-Ali, Haider H; Al-Ghamdi, Abdullah S; Al-Hamaqi, Ghadeer M; Maan, Hawraa S; Al-Mahfoodh, Zainab A; Al-Seba, Hussain Z

    2018-02-01

    To investigate the presence of Legionella spp in cooling tower water. Legionella proliferation in cooling tower water has serious public health implications as it can be transmitted to humans via aerosols and cause Legionnaires' disease. Samples of cooling tower water were collected from King Fahd Hospital of the University (KFHU) (Imam Abdulrahman Bin Faisal University, 2015/2016). The water samples were analyzed by a standard Legionella culture method, real-time polymerase chain reaction (RT-PCR), and 16S rRNA next-generation sequencing. In addition, the bacterial community composition was evaluated. All samples were negative by conventional Legionella culture. In contrast, all water samples yielded positive results by real-time PCR (105 to 106 GU/L). The results of 16S rRNA next generation sequencing showed high similarity and reproducibility among the water samples. The majority of sequences were Alpha-, Beta-, and Gamma-proteobacteria, and Legionella was the predominant genus. The hydrogen-oxidizing gram-negative bacterium Hydrogenophaga was present at high abundance, indicating high metabolic activity. Sphingopyxis, which is known for its resistance to antimicrobials and as a pioneer in biofilm formation, was also detected. Our findings indicate that monitoring of Legionella in cooling tower water would be enhanced by use of both conventional culturing and molecular methods.

  20. Resistance of Legionella and Acanthamoeba mauritaniensis to heat treatment as determined by relative and quantitative polymerase chain reactions.

    PubMed

    Dobrowsky, Penelope H; Khan, Sehaam; Khan, Wesaal

    2017-10-01

    Legionella and Acanthamoeba spp. persist in harvested rainwater pasteurized at high temperatures (> 72°C) and the interaction mechanisms exhibited between these organisms need to be elucidated. The resistance of two Legionella reference strains (Legionella pneumophila ATCC 33152 and Legionella longbeachae ATCC 33462), three environmental strains [Legionella longbeachae (env.), Legionella norrlandica (env.) and Legionella rowbothamii (env.)] and Acanthamoeba mauritaniensis ATCC 50676 to heat treatment (50-90°C) was determined by monitoring culturability and viability [ethidium monoazide quantitative polymerase chain reaction (EMA-qPCR)]. The expression of metabolic and virulence genes of L. pneumophila ATCC 33152 (lolA, sidF, csrA) and L. longbeachae (env.) (lolA) in co-culture with A. mauritaniensis ATCC 50676 during heat treatment (50-90°C) was monitored using relative qPCR. While the culturability (CFU/mL) and viability (gene copies/mL) of the Legionella strains reduced significantly (p < 0.05) following heat treatment (60-90°C), L. longbeachae (env.) and L. pneumophila ATCC 33152 were culturable following heat treatment at 50-60°C. Metabolically active trophozoites and dormant cysts of A. mauritaniensis ATCC 50676 were detected at 50°C and 60-90°C, respectively. For L. pneumophila ATCC 33152, lolA expression remained constant, sidF expression increased and the expression of csrA decreased during co-culture with A. mauritaniensis ATCC 50676. For L. longbeachae (env.), while lolA was up-regulated at 50-70°C, expression was not detected at 80-90°C and in co-culture. In conclusion, while heat treatment may reduce the number of viable Legionella spp. in monoculture, results indicate that the presence of A. mauritaniensis increases the virulence of L. pneumophila during heat treatment. The virulence of Legionella spp. in co-culture with Acanthamoeba spp. should thus be monitored in water distribution systems where temperature (heat) is utilized for treatment

  1. Hartmannella vermiformis inhibition of Legionella pneumophila cultivability

    EPA Science Inventory

    Hartmannella vermiformis is frequently isolated from drinking water (DW) and is permissive to Legionella pneumophila intracellular replication. Thus, H. vermiformis may play an important role in the growth and survival potential of such environmental pathogens. In this study, Pag...

  2. AUTOMATED DEAD-END ULTRAFILTRATION FOR ENHANCED SURVEILLANCE OF LEGIONELLA 2 PNEUMOPHILA AND LEGIONELLA SPP. IN COOLING TOWER WATERS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brigmon, R.; Leskinen, S.; Kearns, E.

    2011-10-10

    Detection of Legionella pneumophila in cooling towers and domestic hot water systems involves concentration by centrifugation or membrane filtration prior to inoculation onto growth media or analysis using techniques such as PCR or immunoassays. The Portable Multi-use Automated Concentration System (PMACS) was designed for concentrating microorganisms from large volumes of water in the field and was assessed for enhancing surveillance of L. pneumophila at the Savannah River Site, SC. PMACS samples (100 L; n = 28) were collected from six towers between August 2010 and April 2011 with grab samples (500 ml; n = 56) being collected before and aftermore » each PMACS sample. All samples were analyzed for the presence of L. pneumophila by direct fluorescence immunoassay (DFA) using FITC-labeled monoclonal antibodies targeting serogroups 1, 2, 4 and 6. QPCR was utilized for detection of Legionella spp. in the same samples. Counts of L. pneumophila from DFA and of Legionella spp. from qPCR were normalized to cells/L tower water. Concentrations were similar between grab and PMACS samples collected throughout the study by DFA analysis (P = 0.4461; repeated measures ANOVA). The same trend was observed with qPCR. However, PMACS concentration proved advantageous over membrane filtration by providing larger volume, more representative samples of the cooling tower environment, which led to reduced variability among sampling events and increasing the probability of detection of low level targets. These data highlight the utility of the PMACS for enhanced surveillance of L. pneumophila by providing improved sampling of the cooling tower environment.« less

  3. Thermal disinfection of hotels, hospitals, and athletic venues hot water distribution systems contaminated by Legionella species.

    PubMed

    Mouchtouri, Varvara; Velonakis, Emmanuel; Hadjichristodoulou, Christos

    2007-11-01

    Legionella spp. (> or = 500 cfu liter(-1)) were detected in 92 of 497 water distribution systems (WDS) examined. Thermal disinfection was applied at 33 WDS. After the first and second application of the disinfection procedure, 15 (45.4%) and 3 (9%) positive for remedial actions WDS were found, respectively. Legionella pneumophila was more resistant to thermal disinfection than Legionella non-pneumophila spp. (relative risk [RR]=5.4, 95% confidence intervals [CI]=1-35). WDS of hotels with oil heater were more easily disinfected than those with electrical or solar heater (RR=0.4 95% CI=0.2-0.8). Thermal disinfection seems not to be efficient enough to eliminate legionellae, unless repeatedly applied and in combination with extended heat flushing, and faucets chlorine disinfection.

  4. Ten Questions Concerning the Aerosolization and Transmission of Legionella in the Built Environment.

    PubMed

    Prussin, Aaron J; Schwake, David Otto; Marr, Linsey C

    2017-10-01

    Legionella is a genus of pathogenic Gram-negative bacteria responsible for a serious disease known as legionellosis, which is transmitted via inhalation of this pathogen in aerosol form. There are two forms of legionellosis: Legionnaires' disease, which causes pneumonia-like symptoms, and Pontiac fever, which causes influenza-like symptoms. Legionella can be aerosolized from various water sources in the built environment including showers, faucets, hot tubs/swimming pools, cooling towers, and fountains. Incidence of the disease is higher in the summertime, possibly because of increased use of cooling towers for air conditioning systems and differences in water chemistry when outdoor temperatures are higher. Although there have been decades of research related to Legionella transmission, many knowledge gaps remain. While conventional wisdom suggests that showering is an important source of exposure in buildings, existing measurements do not provide strong support for this idea. There has been limited research on the potential for Legionella transmission through heating, ventilation, and air conditioning (HVAC) systems. Epidemiological data suggest a large proportion of legionellosis cases go unreported, as most people who are infected do not seek medical attention. Additionally, controlled laboratory studies examining water-to-air transfer and source tracking are still needed. Herein, we discuss ten questions that spotlight current knowledge about Legionella transmission in the built environment, engineering controls that might prevent future disease outbreaks, and future research that is needed to advance understanding of transmission and control of legionellosis.

  5. Sampling and detection of Legionella pneumophila aerosols generated from an industrial cooling tower.

    PubMed

    Ishimatsu, S; Miyamoto, H; Hori, H; Tanaka, I; Yoshida, S

    2001-08-01

    Cooling tower water has frequently been cited as a source of infection in outbreaks of Legionnaires' disease. However, there have been few reports on the presence of legionellae in aerosols from cooling towers. This paper describes our use of an impinger or a six-stage microbial impactor for detecting legionellae in air around a cooling tower contaminated with L. pneumophila (1.2+/-0.3x10(5) CFU/100 ml). Phosphate-buffered saline, Page's saline, 2% yeast extract solution and buffered yeast extract (BYE) broth were tested to evaluate their collection efficiency. These solutions were compared in laboratory experiments using an aerosol of L. pneumophila serogroup (SG) 1. Because BYE broth was the most efficient and storable collecting fluid among them, it was used for outdoor air sampling. In the outdoor air sampling, aerosolized L. pneumophila SG 6 was detected in the air around the cooling tower by the impinger (0.09 CFU/l. air). No legionellae were detected by the impactor with Legionella-selective agar plates (WYOalpha) because the plates were overgrown with fungi. Repetitive element PCR (rep-PCR) and arbitrarily primed PCR (AP-PCR) were employed to assess the epidemiological relationship among Legionella isolates from the air sample and the cooling tower water samples. L. pneumophila SG 6 isolated from the aerosols produced rep-PCR and AP-PCR fingerprints identical to those of L. pneumophila SG 6 strains from the cooling tower water, suggesting that the bacterium was aerosolized from the cooling tower.

  6. [Management of the Legionella-link risk in a multicentre area's hospital: lessons learned of a six-year experience].

    PubMed

    Lecointe, D; Fagundez, E; Pierron, P; Musset, J-P; Brissé, P; Vollereau, D; Breton, D; Théodora, C; Beauvais, R; Malbrunot, C; Crine, L; Fèvre, C

    2010-04-01

    To reduce the Legionella-linked risk in the several sites of Sud-Francilien Hospital, following a hospital-acquired legionellosis case, a multidisciplinary working group performed an action plan monitored through Legionella pneumophila counts in hot water supply. From 2003 to the first half year 2009, positive points for Legionella pneumophila in the main sites of the hospital decreased from 85.71 to 28.00%, representing a significant reduction of 67.33%. Similar results were observed for three of the four establishments, whereas the last did not describe a pronounced reduction of Legionella pneumophila counts and showed constantly serogroup 1 strains. During this period, investigations of additional cases of legionellosis demonstrated a nosocomial transmission in one case in this last site. Multidisciplinary mobilization in management of Legionella-linked risk contributed to these results. Copyright 2009 Elsevier Masson SAS. All rights reserved.

  7. Induction of tumor necrosis factor by Legionella pneumophila.

    PubMed Central

    Blanchard, D K; Djeu, J Y; Klein, T W; Friedman, H; Stewart, W E

    1987-01-01

    Mice were inoculated with Legionella pneumophila via an intratracheal route to establish an experimental model of infection. Lung lavage fluid obtained from infected mice contained a cytolytic factor identified as tumor necrosis factor (TNF). Peak levels of TNF were produced at about 24 h postinfection and rapidly declined thereafter. Treatment of the mice with dextran sulfate before inoculation with the bacteria resulted in lowered amounts of TNF in the lung lavage fluid, suggesting that macrophages were responsible for production of the cytokine. Furthermore, cultures of adherent lung leukocytes and a macrophage cell line, PU 5-1.8, were stimulated to produce TNF by exposure to Legionella antigens. In addition, adherent lung leukocytes from Legionella-infected mice spontaneously released TNF into the culture supernatant. Inoculation of mice with saline or latex particles failed to induce TNF in vivo, indicating that bacterial antigens or products were the stimulating signals. Since there was no detectable TNF activity in sera at any time after intratracheal inoculation, TNF production appeared to be confined to the site of infection. Pretreatment of PU 5-1.8 cultures with gamma interferon, which was detected in the lung lavage fluid before TNF, resulted in augmented TNF production, suggesting cooperativity may exist between the two cytokines, either in the pathogenicity of the bacterium or in a possible immunomodulatory function of TNF and interferon during infection. PMID:2433220

  8. Survival of Legionella in earthquake-induced soil disturbance (liquefaction) in residential areas, Christchurch, New Zealand: implications for disease.

    PubMed

    Graham, Frances F; Harte, David Jg

    2017-05-12

    To investigate a possible link between liquefaction dust exposure and the noticeable increase in legionellosis cases in response to major earthquakes in 2010 and 2011 that resulted in widespread soil disturbance (liquefaction) in parts of Christchurch, New Zealand. We culture tested liquefaction-affected soil for Legionella spp. in the six months following the first earthquake in 2010. Thirty silt samples were collected randomly from locations within Christchurch's metropolitan area that were affected by liquefaction. The samples were tested to determine the presence of Legionella using qualitative and quantitative methods. Liquefaction-affected soil samples from three sites were further subjected to particle size distribution analysis and determination of major oxides. A controlled field study was established using six silt samples and one control (commercial compost), seeded with a wild-type strain of Legionella bozemanae serogroup (sg) 1 and persistence monitored over a 60-day period by culturing for the presence of Legionella. Dry matter determinations were undertaken so that total Legionella could be calculated on a dry weight basis. Legionella bacteria were undetectable after day one in the silt samples. However, L. bozemanae sg1 was detected in the control sample for the entire study period. This study showed that the liquefaction-affected soil could not contribute directly to the observed increase in legionellosis cases after the earthquakes due to its inability to support growth and survival of the Legionella bacteria.

  9. Colonization of Legionella species in Turkish baths in hotels in Alanya, Turkey.

    PubMed

    Erdogan, Haluk; Arslan, Hande

    2015-05-01

    This study evaluated the prevalence of Legionella species in water samples collected from Turkish baths in hotels in Alanya, Turkey, from August 2003 to September 2013. Water samples were collected in 100-mL sterile containers and then concentrated by filtration. Heat treatment was used to eliminate other microorganisms from the samples, which were then spread on Legionella-selective-buffered charcoal yeast extract alpha (BCYE-α) agar and on BCYE-α agar supplemented with glycine, vancomycin, polymyxin, and cycloheximide. Cysteine-dependent colonies were identified by latex agglutination. In total, 135 samples from 52 hotels with Turkish baths were evaluated. Legionella species were identified in 11/52 (21.2%) hotels and 18/135 (13.3%) samples. The most frequently isolated species was Legionella pneumophila, with most isolates belonging to serogroups 6 (55.6%) and 1 (22.2%). The colony count was <100 colony-forming units (CFU) mL(-1) in nine samples, from 100 to 1000 CFU mL(-1) in six samples, and >1000 CFU mL(-1) in three samples. These findings suggest that the hot water systems of Turkish baths in hotels must be viewed as a possible source of travel-associated Legionnaires' disease, and preventative measures should be put in place.

  10. Surveillance and evaluation of the infection risk of free-living amoebae and Legionella in different aquatic environments.

    PubMed

    Ji, Wen-Tsai; Hsu, Bing-Mu; Chang, Tien-Yu; Hsu, Tsui-Kang; Kao, Po-Min; Huang, Kuan-Hao; Tsai, Shiou-Feng; Huang, Yu-Li; Fan, Cheng-Wei

    2014-11-15

    Free-living amoebae (FLA) are ubiquitous in various aquatic environments. Several amoebae species are pathogenic and host other pathogens such as Legionella, but the presence of FLA and its parasites as well as the related infection risk are not well known. In this study, the presence of pathogenic FLA and Legionella in various water bodies was investigated. Water samples were collected from a river, intake areas of drinking water treatment plants, and recreational hot spring complexes in central and southern Taiwan. A total of 140 water samples were tested for the presence of Acanthamoeba spp., Naegleria spp., Vermamoeba vermiformis, and Legionella. In addition, phylogenetic characteristics and water quality parameters were also assessed. The pathogenic genotypes of FLA included Acanthamoeba T4 and Naegleria australiensis, and both were abundant in the hot spring water. In contrast, Legionella pneumophila was detected in different aquatic environments. Among the FLA assessed, V. vermiformis was most likely to coexist with Legionella spp. The total bacteria level was associated with the presence of FLA and Legionella especially in hot spring water. Taken together, FLA contamination in recreational hot springs and drinking water source warrants more attention on potential legionellosis and amoebae infections. Copyright © 2014. Published by Elsevier B.V.

  11. Prevalence of Legionella spp. in water systems of hospitals and hotels in South Western Greece.

    PubMed

    Fragou, K; Kokkinos, P; Gogos, C; Alamanos, Y; Vantarakis, A

    2012-01-01

    The aim of the present study was to determine the prevalence of Legionella spp. in water systems of hospitals and hotels located in South Western Greece, to study the molecular epidemiology of the isolated strains and their possible association with bacterial contamination (total count and Pseudomonas aeruginosa), the water pH, and temperature. A prevalence survey for Legionella spp. by culturing techniques in water distribution systems of eight hospitals and nine hotels occurred in South Western Greece. Water sampling and microbiological analysis were carried out following the ISO methods. Legionella pneumophila was detected in 33% and 36% of the distribution systems of hospitals and hotels, respectively. Our survey results suggest a frequent prevalence of elevated concentrations of Legionella spp. in water systems of hospitals and hotels. Our investigation has confirmed the need to regularly monitor the microbiological condition of water systems in hospitals and hotels.

  12. Legionella Pneumonia Complicated with Acquired Fanconi Syndrome: A Case Report.

    PubMed

    Koda, Ryo; Itoh, Ryo; Tsuchida, Masafumi; Ohashi, Kazumasa; Iino, Noriaki; Takada, Toshinori; Narita, Ichiei

    2018-06-06

    Legionella pneumonia is occasionally accompanied by renal complications; however, the cause of this remains unknown. We herein report a 70-year-old Japanese man with Legionella pneumonia who presented with hyponatremia, hypophosphatemia, and hypouricemia. The levels of urinary β2-microglobulin and N-acetyl-β-D-glucosaminidase were remarkably high, indicating severe renal tubular damage. The presence of glycosuria and aminoaciduria as well as increased fractional excretion of uric acid and decreased tubular reabsorption of phosphate indicated that the patient's condition was complicated with Fanconi syndrome. After antimicrobial therapy, the electrolyte abnormalities and renal tubular damage were completely resolved.

  13. Interactive Effects of Corrosion, Copper, and Chloramines on Legionella and Mycobacteria in Hot Water Plumbing.

    PubMed

    Rhoads, William J; Pruden, Amy; Edwards, Marc A

    2017-06-20

    Complexities associated with drinking water plumbing systems can result in undesirable interactions among plumbing components that undermine engineering controls for opportunistic pathogens (OPs). In this study, we examine the effects of plumbing system materials and two commonly applied disinfectants, copper and chloramines, on water chemistry and the growth of Legionella and mycobacteria across a transect of bench- and pilot-scale hot water experiments carried out with the same municipal water supply. We discovered that copper released from corrosion of plumbing materials can initiate evolution of >1100 times more hydrogen (H 2 ) from water heater sacrificial anode rods than does presence of copper dosed as soluble cupric ions. H 2 is a favorable electron donor for autotrophs and causes fixation of organic carbon that could serve as a nutrient for OPs. Dosed cupric ions acted as a disinfectant in stratified stagnant pipes, inhibiting culturable Legionella and biofilm formation, but promoted Legionella growth in pipes subject to convective mixing. This difference was presumably due to continuous delivery of nutrients to biofilm on the pipes under convective mixing conditions. Chloramines eliminated culturable Legionella and prevented L. pneumophila from recolonizing biofilms, but M. avium gene numbers increased by 0.14-0.76 logs in the bulk water and were unaffected in the biofilm. This study provides practical confirmation of past discrepancies in the literature regarding the variable effects of copper on Legionella growth, and confirms prior reports of trade-offs between Legionella and mycobacteria if chloramines are applied as secondary disinfectant residual.

  14. Isolation of a gene encoding a novel spectinomycin phosphotransferase from Legionella pneumophila.

    PubMed

    Suter, T M; Viswanathan, V K; Cianciotto, N P

    1997-06-01

    A gene capable of conferring spectinomycin resistance was isolated from Legionella pneumophila, the agent of Legionnaires' disease. The gene (aph) encoded a 36-kDa protein which has similarity to aminoglycoside phosphotransferases. Biochemical analysis confirmed that aph encodes a phosphotransferase which modifies spectinomycin but not hygromycin, kanamycin, or streptomycin. The strain that was the source of aph demonstrated resistance to spectinomycin, and Southern hybridizations determined that aph also exists in other legionellae.

  15. Isolation of a gene encoding a novel spectinomycin phosphotransferase from Legionella pneumophila.

    PubMed Central

    Suter, T M; Viswanathan, V K; Cianciotto, N P

    1997-01-01

    A gene capable of conferring spectinomycin resistance was isolated from Legionella pneumophila, the agent of Legionnaires' disease. The gene (aph) encoded a 36-kDa protein which has similarity to aminoglycoside phosphotransferases. Biochemical analysis confirmed that aph encodes a phosphotransferase which modifies spectinomycin but not hygromycin, kanamycin, or streptomycin. The strain that was the source of aph demonstrated resistance to spectinomycin, and Southern hybridizations determined that aph also exists in other legionellae. PMID:9174205

  16. Detection of Legionella species in environmental water by the quantitative PCR method in combination with ethidium monoazide treatment.

    PubMed

    Inoue, Hiroaki; Takama, Tomoko; Yoshizaki, Miwa; Agata, Kunio

    2015-01-01

    We detected Legionella species in 111 bath water samples and 95 cooling tower water samples by using a combination of conventional plate culture, quantitative polymerase chain reaction (qPCR) and qPCR combined with ethidium monoazide treatment (EMA-qPCR) methods. In the case of bath water samples, Legionella spp. were detected in 30 samples by plate culture, in 85 samples by qPCR, and in 49 samples by EMA-qPCR. Of 81 samples determined to be Legionella-negative by plate culture, 56 and 23 samples were positive by qPCR and EMA-qPCR, respectively. Therefore, EMA treatment decreased the number of Legionella-positive bath water samples detected by qPCR. In contrast, EMA treatment had no effect on cooling tower water samples. We therefore expect that EMA-qPCR is a useful method for the rapid detection of viable Legionella spp. from bath water samples.

  17. Susceptibilities of Legionella spp. to Newer Antimicrobials In Vitro

    PubMed Central

    Schülin, T.; Wennersten, C. B.; Ferraro, M. J.; Moellering, R. C.; Eliopoulos, G. M.

    1998-01-01

    The in vitro activities of 13 antimicrobial agents against 30 strains of Legionella spp. were determined. Rifapentine, rifampin, and clarithromycin were the most potent agents (MICs at which 90% of isolates are inhibited [MIC90s], ≤0.008 μg/ml). The ketolide HMR 3647 and the fluoroquinolones levofloxacin and BAY 12-8039 (MIC90s, 0.03 to 0.06 μg/ml) were more active than erythromycin A or roxithromycin. The MIC90s of dalfopristin-quinupristin and linezolid were 0.5 and 8 μg/ml, respectively. Based on class characteristics and in vitro activities, several of these agents may have potential roles in the treatment of Legionella infections. PMID:9624509

  18. Recirculation, stagnation and ventilation: The 2014 legionella episode

    NASA Astrophysics Data System (ADS)

    Russo, Ana; Soares, Pedro M. M.; Gouveia, Célia M.; Cardoso, Rita M.; Trigo, Ricardo M.

    2017-04-01

    Legionella transmission through the atmosphere is unusual, but not unprecedented. A scientific paper published in 2006 reports a surge in Pas-de-Calais, France, in which 86 people have been infected by bacteria released by a cooling tower more than 6 km away [3]. Similarly, in Norway, in 2005, there was another case where contamination spread beyond 10 km, although more concentrated within a radius of 1 km from an industrial unit [2]. An unprecedented large Legionella outbreak occurred in November 2014 nearby Lisbon, Portugal. As of 7 November 2014, 375 individuals become hill and 12 died infected by the Legionella pneumophila bacteria, contracted by inhalation of steam droplets of contaminated water (aerosols). These droplets are so small that can carry the bacteria directly to the lungs, depositing it in the alveoli. One way of studying the propagation of legionella episodes is through the use of aerosol dispersion models. However, such approaches often require detailed 3D high resolution wind data over the region, which isn't often available for long periods. The likely impact of wind on legionella transmission can also be understood based on the analysis of special types of flow conditions such as stagnation, recirculation and ventilation [1, 4]. The Allwine and Whiteman (AW) approach constitutes a straightforward method to assess the assimilative and dispersal capacities of different airsheds [1,4], as it only requires hourly wind components. Thus, it has the advantage of not needing surface and upper air meteorological observations and a previous knowledge of the atmospheric transport and dispersion conditions. The objective of this study is to analyze if the legionella outbreak event which took place in November 2014 had extreme potential recirculation and/or stagnation characteristics. In order to accomplish the proposed objective, the AW approach was applied for a hindcast time-series covering the affected area (1989-2007) and then for an independent

  19. Legionella norrlandica sp. nov., isolated from the biopurification systems of wood processing plants.

    PubMed

    Rizzardi, Kristina; Winiecka-Krusnell, Jadwiga; Ramliden, Miriam; Alm, Erik; Andersson, Sabina; Byfors, Sara

    2015-02-01

    Fourteen isolates of an unknown species identified as belonging to the genus Legionella by selective growth on BCYE agar were isolated from the biopurification systems of three different wood processing plants. The mip gene sequence of all 14 isolates was identical and a close match alignment revealed 86 % sequence similarity with Legionella pneumophila serogroup 8. The whole genome of isolate LEGN(T) was sequenced, and a phylogenetic tree based on the alignment of 16S rRNA, mip, rpoB, rnpB and the 23S-5S intergenic region clustered LEGN(T) with L. pneumophila ATCC 33152(T). Analysis of virulence factors showed that strain LEGN(T) carries the majority of known L. pneumophila virulence factors. An amoeba infection assay performed to assess the pathogenicity of strain LEGN(T) towards Acanthamoeba castellanii showed that it can establish a replication vacuole in A. castellanii but does not significantly affect replication of amoebae. Taken together, the results confirm that strain LEGN(T) represents a novel species of the genus Legionella, for which the name Legionella norrlandica sp. nov. is proposed. The type strain is LEGN(T) ( = ATCC BAA-2678(T) = CCUG 65936(T)). © 2015 IUMS.

  20. Comparison of potentially pathogenic free-living amoeba hosts by Legionella spp. in substrate-associated biofilms and floating biofilms from spring environments.

    PubMed

    Hsu, Bing-Mu; Huang, Chin-Chun; Chen, Jung-Sheng; Chen, Nai-Hsiung; Huang, Jen-Te

    2011-10-15

    This study compares five genera of free-living amoebae (FLA) hosts by Legionella spp. in the fixed and floating biofilm samples from spring environments. Detection rate of Legionella spp. was 26.9% for the floating biofilms and 3.1% for the fixed biofilms. Acanthamoeba spp., Hartmanella vermiformis, and Naegleria spp. were more frequently detected in floating biofilm than in fixed biofilm samples. The percentage of pathogenic Acanthamoeba spp. among all the genus Acanthamoeba detected positive samples was 19.6%. The potential pathogenic Naegleria spp. (for example, Naegleria australiensis, Naegleria philippinensis, and Naegleria italica) was 54.2% to all the Naegleria detected positive samples. In the study, 12 serotypes of possible pneumonia causing Legionella spp. were detected, and their percentage in all the Legionella containing samples was 42.4%. The FLA parasitized by Legionella included unnamed Acanthamoeba genotype, Acanthamoeba griffini, Acanthamoeba jacobsi, H. vermiformis, and N. australiensis. Significant differences were also observed between the presence/absence of H. vermiformis and Legionella parasitism in FLA. Comparisons between the culture-confirmed method and the PCR-based detection method for detecting FLA and Legionella in biofilms showed great variation. Therefore, using these analysis methods together to detect FLA and Legionella is recommended. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. Detection of viable but non-culturable legionella in hospital water network following monochloramine disinfection.

    PubMed

    Casini, B; Baggiani, A; Totaro, M; Mansi, A; Costa, A L; Aquino, F; Miccoli, M; Valentini, P; Bruschi, F; Lopalco, P L; Privitera, G

    2018-01-01

    Prevention of legionellosis remains a critical issue in healthcare settings where monochloramine (MC) disinfection was recently introduced as an alternative to chlorine dioxide in controlling Legionella spp. contamination of the hospital water network. Continuous treatments with low MC doses in some instances have induced a viable but non-culturable state (VBNC) of Legionella spp. To investigate the occurrence of such dormant cells during a long period of continuous MC treatment. Between November 2010 and April 2015, 162 water and biofilm samples were collected and Legionella spp. isolated in accordance with standard procedures. In sampling sites where MC was <1.5mg/L, VBNC cells were investigated by ethidium monoazide bromide (EMA)-real-time polymerase chain reaction (qPCR) and 'resuscitation' test into Acanthamoeba polyphaga CCAP 1501/18. According to the Health Protection Agency protocol, free-living protozoa were researched in 60 five-litre water samples. In all, 136 out of 156 (87.2%) of the samples taken from sites previously positive for L. pneumophila ST269 were negative by culture, but only 47 (34.5%) negative by qPCR. Although no positive results were obtained by EMA-qPCR, four out of 22 samples associated with MC concentration of 1.3 ± 0.5mg/L showed VBNC legionella resuscitation. The presence of the amoeba A. polyphaga in the hospital water network was demonstrated. Our study is the first report evidencing the emergence of VNBC legionella during a long period of continuous MC treatment of a hospital water network, highlighting the importance of keeping an appropriate and uninterrupted MC dosage to ensure the control of legionella colonization in hospital water supplies. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  2. A case of pneumonia caused by Legionella pneumophila serogroup 12 and treated successfully with imipenem.

    PubMed

    Nishizuka, Midori; Suzuki, Hiroki; Ara, Tomoka; Watanabe, Mari; Morita, Mami; Sato, Chisa; Tsuchida, Fumihiro; Seto, Junji; Amemura-Maekawa, Junko; Kura, Fumiaki; Takeda, Hiroaki

    2014-06-01

    The patient was an 83-year-old man hospitalized for Haemophilus influenzae pneumonia, who developed recurrent pneumonia after improvement of the initial episode. Legionella pneumophila serogroup 12 was isolated from the sputum, accompanied by increased serum antibody titers to L. pneumophila serogroup 12. Therefore, the patient was diagnosed as having Legionella pneumonia caused by L. pneumophila serogroup 12. Case reports of pneumonia caused by L. pneumophila serogroup 12 are rare, and the case described herein is the first report of clinical isolation of this organism in Japan. When the genotype was determined by the protocol of The European Working Group for Legionella Infections (Sequence-Based Typing [SBT] for epidemiological typing of L. pneumophila, Version 3.1), the sequence type was ST68. Imipenem/cilastatin therapy was found to be effective for the treatment of Legionella pneumonia in this patient. Copyright © 2014 Japanese Society of Chemotherapy and The Japanese Association for Infection Disease. Published by Elsevier Ltd. All rights reserved.

  3. [Evaluation of a Legionella outbreak emerged in a recently opening hotel].

    PubMed

    Erdoğan, Haluk; Arslan, Hande

    2013-04-01

    Legionnaires' disease (LD) is a systemic infection caused by Legionella species especially colonized in the water systems. Hotels are common locations in which waterwork-associated sporadic or epidemic legionellosis can be detected. The aim of this study was to evaluate a small Legionella outbreak emerged in a recently opened 600-bed hotel in Alanya, a touristic county in Mediterranean part of Turkey. A 66 years old male patient who stayed in this hotel opened on May 15th, 2009, was admitted to our hospital on May 21st, 2009 with the complaints of high fever, headache and diarrhea lasting for three days. Since chest X-ray revealed non-homogenous density increase in left middle and inferior zone, the patient was diagnosed as atypical pneumoniae and LD was confirmed by positive urinary Legionella antigen test (Card test, BinaxNOW®Legionella Urinary Antigen Test; Alere Co, USA) result. Following the identification of the index case, the records of our hospital were reviewed and revealed another case being treated with the diagnosis of community acquired pneumonia who was also the guest of the same hotel. This patient was then diagnosed as LD by positive urinary antigen test. Since new cases were identified during the following days (May 22, 25 and 26) the Antalya County Health Department and hotel management were informed about a cluster of LD. In addition subsequent investigation for environmental surveillance and water sampling were conducted. The LD diagnosis and environmental inspections were performed according to the procedure described in the guideline from "Turkish Ministry of Health Travel-Associated Legionnaires' Disease Control Programme". Five definitive cases and one presumptive case of LD were identified during the outbreak period (May 20-26, 2009). All of the cases were successfully treated (intravenous ciprofloxacin or levofloxacin or clarithromycin), however one patient died due to sudden death during sleep after being discharged. Since sputum

  4. Molecular characterization of viable Legionella spp. in cooling tower water samples by combined use of ethidium monoazide and PCR.

    PubMed

    Inoue, Hiroaki; Fujimura, Reiko; Agata, Kunio; Ohta, Hiroyuki

    2015-01-01

    Viable Legionella spp. in environmental water samples were characterized phylogenetically by a clone library analysis combining the use of ethidium monoazide and quantitative PCR. To examine the diversity of Legionella spp., six cooling tower water samples and three bath water samples were collected and analyzed. A total of 617 clones were analyzed for their 16S rRNA gene sequences and classified into 99 operational taxonomic units (OTUs). The majority of OTUs were not clustered with currently described Legionella spp., suggesting the wide diversity of not-yet-cultured Legionella groups harbored in cooling tower water environments.

  5. Molecular Characterization of Viable Legionella spp. in Cooling Tower Water Samples by Combined Use of Ethidium Monoazide and PCR

    PubMed Central

    Inoue, Hiroaki; Fujimura, Reiko; Agata, Kunio; Ohta, Hiroyuki

    2015-01-01

    Viable Legionella spp. in environmental water samples were characterized phylogenetically by a clone library analysis combining the use of ethidium monoazide and quantitative PCR. To examine the diversity of Legionella spp., six cooling tower water samples and three bath water samples were collected and analyzed. A total of 617 clones were analyzed for their 16S rRNA gene sequences and classified into 99 operational taxonomic units (OTUs). The majority of OTUs were not clustered with currently described Legionella spp., suggesting the wide diversity of not-yet-cultured Legionella groups harbored in cooling tower water environments. PMID:25736979

  6. Evaluation of Legionella real-time PCR against traditional culture for routine and public health testing of water samples.

    PubMed

    Collins, S; Stevenson, D; Walker, J; Bennett, A

    2017-06-01

    To evaluate the usefulness of Legionella qPCR alongside traditional culture for enumeration of Legionella from water samples as part of both routine and public health investigation testing. Routine water samples (n = 2002) and samples from public health investigations (n = 215) were analysed by culture and qPCR for Legionella spp., Legionella pneumophila and L. pneumophila sg-1. A negative qPCR result was highly predictive of a negative culture result for all water systems (negative predictive values, NPV from 97·4 to 100%). Positive predictive values (PPV) were lower (0-50%). Results for qPCR were generally larger than culture with average log 10 differences of 1·1 for Legionella spp. and 1·2 for L. pneumophila. Alert and action levels of 1000 and 10 000 GU per litre, respectively, are proposed for Legionella qPCR for hot and cold water systems (HCWS). The use of qPCR significantly reduced the time to results for public health investigations by rapidly identifying potential sources and ruling out others, thus enabling a more rapid and efficient response. The high NPV of qPCR supports its use to rapidly screen out negative samples without culture. Alert and action levels for Legionella qPCR for HCWS are proposed. Quantitative PCR will be a valuable tool for both routine and public health testing. This study generated comparative data of >2000 water samples by qPCR and culture. Action and alert levels have been recommended that could enable duty holders to interpret qPCR results to facilitate timely Legionella control and public health protection. © 2017 Crown copyright. Journal of Applied Microbiology © 2017 The Society for Applied Microbiology.

  7. Application of unstable Gfp variants to the kinetic study of Legionella pneumophila icm gene expression during infection.

    PubMed

    Barysheva, Oksana V; Fujii, Jun; Takaesu, Giichi; Yoshida, Shin-ichi

    2008-04-01

    An unstable type of green fluorescent protein (Gfp) tagged with a C-terminal extension, which is a target for tail-specific protease, was used as a reporter gene in Legionella pneumophila. To analyse Gfp expression in legionellae, transcriptional fusions of unstable gfp with the Legionella-specific icm (intracellular multiplication) promoters (P(icmS), P(icmT) and P(icmQ)) were constructed. Infection studies using J774.1 macrophages as the host, and L. pneumophila strains carrying P(icmS)-gfp, P(icmT)-gfp and P(icmQ)-gfp fusions, indicated that the icmS, icmT and icmQ genes could be expressed intracellularly. Expression of icmS, icmT and icmQ genes in infected cells was examined by flow cytometry. Furthermore, fluorescent intracellular legionellae were detected directly by confocal microscopy. Real-time quantitative RT-PCR revealed the differences in the gene expression of icmS, and that of icmT and icmQ, during infection. Expression of icmS was high in the late stage of infection, while that of icmT and icmQ was high in the early phase only. We show that unstable gfp is a useful reporter gene whose expression in legionellae can be followed in real-time, and that it allows analysis of promoter activities in legionellae and monitoring of the infection process.

  8. Community acquired pneumonia by Legionella pneumophila: Study of 136 cases.

    PubMed

    Romay-Lema, Eva; Corredoira-Sánchez, Juan; Ventura-Valcárcel, Pablo; Iñiguez-Vázquez, Iria; García Pais, María-José; García-Garrote, Fernando; Rabuñal Rey, Ramón

    2018-04-25

    Most of the data on Legionella pneumonia in our country come from the Mediterranean area, and there are few studies from the Northwest area. This study tries to assess the situation of this infection in this area. Retrospective study of all patients with positive Legionella antigenuria treated at the University Hospital Lucus Augusti in Lugo (Spain) from 2001, the year in which this test was introduced in our centre, until 2015. We analysed epidemiological data, risk factors, clinical, radiological and biochemical findings, and clinical outcome. The sampled included 136 patients. When comparing the first five years of the study with the last five, the incidence increased from 10.9 to 64.5 cases/1,000,000; the number of antigenuria requests increased 3.4 times, and compared to other pneumonia aetiologies Legionella increased from 0.9% to 15%. The mean age was 64.1years and 84.6% were males; 74.3% had comorbidities. Males were significantly younger (62.7±16.6 vs 71.9±17.3) and consumed more alcohol (26.1% vs 0%) and tobacco (67.8% vs 14.3%). Diagnosis was established within the first 72hours in 88.9% of cases and most received levofloxacin (95.6%). Hospitalisation was needed in 85% of cases, 11.7% in ICU and 4.4% died. After the introduction of antigenuria there was an increase in the incidence of Legionella pneumonia recorded in our health area. Its rate in recent years has been one of the highest in our country. Despite the fact that the patients had advanced age and comorbidities, mortality was low. Copyright © 2018 Elsevier España, S.L.U. All rights reserved.

  9. Presence of Legionella spp. in Hot Water Networks of Different Italian Residential Buildings: A Three-Year Survey.

    PubMed

    Totaro, Michele; Valentini, Paola; Costa, Anna Laura; Frendo, Lorenzo; Cappello, Alessia; Casini, Beatrice; Miccoli, Mario; Privitera, Gaetano; Baggiani, Angelo

    2017-10-26

    Although the European reports highlight an increase in community-acquired Legionnaires' disease cases, the risk of Legionella spp. in private houses is underestimated. In Pisa (Italy) we performed a three-year survey on Legionella presence in 121 buildings with an independent hot water production (IB); 64 buildings with a central hot water production (CB); and 35 buildings with a solar thermal system for hot water production (TB). From all the 220 buildings Legionella spp. was researched in two hot water samples collected either at the recirculation point or on the first floor and on the last floor, while the potable water quality was analysed in three cold water samples collected at the inlet from the aqueduct network, at the exit from the autoclave, and at the most remote tap. Legionella pneumophila sg1, Legionella pneumophila sg2-16, and non- pneumophila Legionella species were detected in 26% of the hot water networks, mostly in CB and TB. In these buildings we detected correlations between the presence of Legionella and the total chlorine concentration decrease and/or the increase of the temperature. Cold water resulted free from microbiological hazards, with the exception of Serratia liquefaciens and Enterobacter cloacae isolated at the exit from two different autoclaves. We observed an increase in total microbial counts at 22 °C and 37 °C between the samples collected at the most remote taps compared to the ones collected at the inlet from the aqueduct. The study highlights a condition of potential risk for susceptible categories of population and supports the need for measures of risk assessment and control.

  10. Presence of Legionella spp. in Hot Water Networks of Different Italian Residential Buildings: A Three-Year Survey

    PubMed Central

    Totaro, Michele; Valentini, Paola; Costa, Anna Laura; Frendo, Lorenzo; Cappello, Alessia; Casini, Beatrice; Miccoli, Mario; Privitera, Gaetano; Baggiani, Angelo

    2017-01-01

    Although the European reports highlight an increase in community-acquired Legionnaires’ disease cases, the risk of Legionella spp. in private houses is underestimated. In Pisa (Italy) we performed a three-year survey on Legionella presence in 121 buildings with an independent hot water production (IB); 64 buildings with a central hot water production (CB); and 35 buildings with a solar thermal system for hot water production (TB). From all the 220 buildings Legionella spp. was researched in two hot water samples collected either at the recirculation point or on the first floor and on the last floor, while the potable water quality was analysed in three cold water samples collected at the inlet from the aqueduct network, at the exit from the autoclave, and at the most remote tap. Legionella pneumophila sg1, Legionella pneumophila sg2–16, and non-pneumophila Legionella species were detected in 26% of the hot water networks, mostly in CB and TB. In these buildings we detected correlations between the presence of Legionella and the total chlorine concentration decrease and/or the increase of the temperature. Cold water resulted free from microbiological hazards, with the exception of Serratia liquefaciens and Enterobacter cloacae isolated at the exit from two different autoclaves. We observed an increase in total microbial counts at 22 °C and 37 °C between the samples collected at the most remote taps compared to the ones collected at the inlet from the aqueduct. The study highlights a condition of potential risk for susceptible categories of population and supports the need for measures of risk assessment and control. PMID:29072607

  11. [Clinical manifestations of Legionella pneumonia in hematology patients].

    PubMed

    Galstian, G M; Kostina, I É; Katrysh, S A; Kliasova, G A; Karpova, T I; Tartakovskiĭ, I S

    2014-01-01

    To detect the most common clinical manifestations of Legionella pneumonia (LP) in immunocompromized patients. Clinical manifestations, the results of investigation of bronchoalveolar lavage fluid (BALF) and urine, and the data of lung computed tomography (CT) were studied in patients with blood system diseases and acute respiratory failure (ARF). The diagnosis of LP was verified in 8 (10.5%) of 76 patients with blood system diseases and ARF. The disease manifested as fever, higher concentrations of inflammatory markers (procalcitonin, fibrinogen), ARF, hypoxemia, and infiltrative lung injury. Six of the 8 patients were switched to mechanical ventilation. Lung CT showed no pathognomonic signs. Five of the 8 patients were observed to have renal dysfunction. The diagnosis of LP was made on the basis of the results of BALF examination in 7 patients and urinary antigen detection in 1. The disease was caused by Legionella pneumophila serogroup 1 in 3 patients and by L. pneumophila of other serogroups in the other patients. Therapy with respiratory fluoroquinolones was performed in 5 patients. Three patients died from progressive ARF and hypoxemia. BALF results were obtained after their death and therapy for legionellosis was not initiated. The incidence of LP is 10.5% in hematology patients. The clinical manifestations of legionellosis are nonspecific; its diagnosis requires bacteriological and/or serological evidence. Due to the high risk of death, it is reasonable to preuse respiratory fluoroquinolones or macrolides in immunocompromized patients with progressive ARF and suspected Legionella pneumonia before diagnosis.

  12. Post-translational modifications are key players of the Legionella pneumophila infection strategy

    PubMed Central

    Michard, Céline; Doublet, Patricia

    2015-01-01

    Post-translational modifications (PTMs) are widely used by eukaryotes to control the enzymatic activity, localization or stability of their proteins. Traditionally, it was believed that the broad biochemical diversity of the PTMs is restricted to eukaryotic cells, which exploit it in extensive networks to fine-tune various and complex cellular functions. During the last decade, the advanced detection methods of PTMs and functional studies of the host–pathogen relationships highlight that bacteria have also developed a large arsenal of PTMs, particularly to subvert host cell pathways to their benefit. Legionella pneumophila, the etiological agent of the severe pneumonia legionellosis, is the paradigm of highly adapted intravacuolar pathogens that have set up sophisticated biochemical strategies. Among them, L. pneumophila has evolved eukaryotic-like and rare/novel PTMs to hijack host cell processes. Here, we review recent progress about the diversity of PTMs catalyzed by Legionella: ubiquitination, prenylation, phosphorylation, glycosylation, methylation, AMPylation, and de-AMPylation, phosphocholination, and de-phosphocholination. We focus on the host cell pathways targeted by the bacteria catalyzed PTMs and we stress the importance of the PTMs in the Legionella infection strategy. Finally, we highlight that the discovery of these PTMs undoubtedly made significant breakthroughs on the molecular basis of Legionella pathogenesis but also lead the way in improving our knowledge of the eukaryotic PTMs and complex cellular processes that are associated to. PMID:25713573

  13. Detection of Legionella-contaminated aerosols in the vicinity of a bio-trickling filter of a breeding sow facility - A pilot study.

    PubMed

    Walser, Sandra M; Brenner, Bernhard; Wunderlich, Anika; Tuschak, Christian; Huber, Stefanie; Kolb, Stefanie; Niessner, Reinhard; Seidel, Michael; Höller, Christiane; Herr, Caroline E W

    2017-01-01

    The urbanization of agricultural areas results in a reduction of distances between residential buildings and livestock farms. In the public debate, livestock farming is increasingly criticized due to environmental disturbance and odor nuisance originating from such facilities. One method to reduce odor and ammonia is by exhaust air treatment, for example, by biological exhaust air purification processes with bio-trickling filters filled with tap water. Higher temperatures in the summer time and the generation of biofilms are ideal growth conditions for Legionella. However, there are no studies on the presence of Legionella in the water of bio-trickling filters and the release of Legionella-containing aerosols. Therefore, the aim of this study was to investigate Legionella in wash water and emitted bioaerosols of a bio-trickling filter system of a breeding sow facility. For this purpose, measurements were carried out using a cyclone sampler. In addition, samples of wash water were taken. Legionella were not found by culture methods. However, using molecular biological methods, Legionella spp. could be detected in wash water as well as in bioaerosol samples. With antibody-based methods, Legionella pneumophila were identified. Further studies are needed to investigate the environmental health relevance of Legionella-containing aerosols emitted by such exhaust air purification systems. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. [A case of Legionella pneumonia with multiple organ failure].

    PubMed

    Li, Jiali; Wen, Rui; Deng, Hong; Li, Qian

    2016-06-28

    Legionella pneumonia (LP) is a rare systemic infectious disease, which is often misdiagnosed by clinicians due to the atypical symptoms. A middle-aged man who suffered from fever and dyspnea was diagnosed as community acquired pneumonia (CAP) in Changsha Central Hospital in March 2015. The treatment was unsatisfied firstly. The patients showed further symptoms of rhabdomyolysis, acute liver and renal failure, and impaired neural functions, who was diagnosed as LP with multiple organ failure based on a positive test for Legionella antibody. The patient was recovered after treated with moxifloxacin combined with azithromycin and continuous renal replacement therapy. LP should be paid attention when patient was diagnosed as CAP and failed to be treated. The satisfied outcome is achieved after application of macrolide, quinolones and comprehensive treatments.

  15. A Case of Community-Acquired Pneumonia Due to Legionella pneumophila Serogroup 9 Wherein Initial Treatment with Single-Dose Oral Azithromycin Appeared Useful.

    PubMed

    Ito, Akihiro; Ishida, Tadashi; Tachibana, Hiromasa; Ito, Yuhei; Takaiwa, Takuya; Fujii, Hiroyuki; Hashimoto, Toru; Nakajima, Hiroshi; Amemura-Maekawa, Junko

    2017-11-22

    Legionella species are important causative pathogens for severe community-acquired pneumonia (CAP). Most cases of Legionella pneumonia are due to Legionella pneumophila serogroup 1, and CAP due to L. pneumophila serogroup 9 is rare. A fourth case of CAP due to L. pneumophila serogroup 9 has been reported, and initial treatment using single-dose oral azithromycin appeared useful. Azithromycin or fluoroquinolone injection is usually recommended for the treatment of Legionella pneumonia, and no previous reports have shown the effectiveness of single-dose oral azithromycin. This case report is therefore valuable from the perspective of possible treatment for mild to moderate Legionella pneumonia using single-dose oral azithromycin.

  16. Hospital-acquired Legionella infections: an update on the procedures for controlling environmental contamination.

    PubMed

    Borella, P; Bargellini, A; Marchegiano, P; Vecchi, E; Marchesi, I

    2016-01-01

    The waterborne healthcare-associated infections are mainly sustained by Legionella and Pseudomonas spp. Various water factors and plumbing characteristics, and the interaction with other water microorganisms are considered to be predictive of Legionella contamination. It is therefore mandatory to organize plans of surveillance, prevention and control in order to avoid disease appearance in immunosuppressed patients, with higher risk of death. Guidelines for the prevention of Legionnaires' disease have been published, benefiting those who face this problem, but definitive standardized solutions do not exist yet. Here we describe fifteen years of activity, during which our study group gathered interesting data on the control of Legionella contamination. Water disinfection is not generally sufficient to control the risk of infection, but a complex water safety plan should be developed, including system maintenance, training of staff and implementation of a clinical surveillance system aimed at early detection of cases. Concerning the control measures, we evaluated the effectiveness of different treatments suggested to reduce Legionella spp contamination, comparing our results with the current literature data. The performance ranking was highest for the filter, followed by boilers at high temperature, monochloramine and, at a lower level, chlorine dioxide; the effectiveness of hyperchlorination was limited, and thermal shock was even more ineffective.

  17. Genetic relatedness of Legionella longbeachae isolates from human and environmental sources in Australia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lanser, J.A.; Doyle, R.; Sangster, N.

    1990-09-01

    The genetic relatedness of Legionella longbeachae isolated in Australia since 1987 was investigated by restriction fragment length polymorphism (RFLP) analysis and allozyme electrophoresis. Three radiolabeled probes were used in Southern hybridizations for the RFLP studies. They were Escherichia coli 16S and 23S rRNA and cloned fragments of L. longbeachae selected empirically from genomal banks in lambda and a cosmid. The legionellae included in the study comprised 11 Legionella longbeachae serogroup 1 organisms isolated form humans, 28 L. longbeachae serogroup 1 isolates from environmental sources, 3 L. longbeachae serogroup 2 environmental isolates. These were compared with the American Type Culture Collectionmore » reference strains of both serogroups and some other related Legionella species. Results of allozyme and RFLP analysis showed that all the isolates from humans and all but three of the environmental L. longbeachae serogroup 1 isolates were closely related. They were also closely related to L. longbeachae serogroup 1 ATCC 33462. There was wider variation among the three L. longbeachae serogroup 2 environmental isolates. One of these was closely related to L. longbeachae serogroup 2 ATCC 33484. RFLP studies with the rRNA probe provided the most discrimination among isolates but did not distinguish between the two serogroups.« less

  18. Use of copper-silver ionization for the control of legionellae in alkaline environments at health care facilities.

    PubMed

    Dziewulski, David M; Ingles, Erin; Codru, Neculai; Strepelis, John; Schoonmaker-Bopp, Dianna

    2015-09-01

    There are multiple treatment options for the control of legionellae in premise hot water systems. Water chemistry plays a role in the efficacy of these treatments and should be considered when selecting a treatment. This study demonstrated the efficacy of copper-silver ionization (CSI) under alkaline water conditions in 2 health care facilities. Monitoring for copper (Cu) and silver (Ag) ions was performed, and the corresponding percentage of positive Legionella cultures was monitored. Low Legionella colony forming units (CFU), with a mean <10 CFU/100 mL, and ≤30% positive culture for each sampling period, along with no recurrent disease, were considered indicative of control. CSI treatment was shown to reduce both the number of CFU found and the percentage of samples found to be culture positive. After treatment was established, culture positivity was, for example, reduced from 70% (>10(3) CFU/100 mL) to consistently <30% (38 CFU/100 mL). Control of legionellae in premise water systems may be a complex process requiring long-term assessments for adequate control. This work found that CSI could be successful in controlling Legionella under alkaline water conditions, and the evidence suggests that Ag ions are responsible for the control of Legionella pneumophila 1, L pneumophila 6, and L anisa. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  19. Viability-qPCR for detecting Legionella: Comparison of two assays based on different amplicon lengths.

    PubMed

    Ditommaso, Savina; Giacomuzzi, Monica; Ricciardi, Elisa; Zotti, Carla M

    2015-08-01

    Two different real-time quantitative PCR (PMA-qPCR) assays were applied for quantification of Legionella spp. by targeting a long amplicon (approx 400 bp) of 16S rRNA gene and a short amplicon (approx. 100 bp) of 5S rRNA gene. Purified DNA extracts from pure cultures of Legionella spp. and from environmental water samples were quantified. Application of the two assays to quantify Legionella in artificially contaminated water achieved that both assays were able to detect Legionella over a linear range of 10 to 10(5) cells ml(-1). A statistical analysis of the standard curves showed that both assays were linear with a good correlation coefficient (R(2) = 0.99) between the Ct and the copy number. Amplification with the reference assay was the most effective for detecting low copy numbers (1 bacterium per PCR mixture). Using selective quantification of viable Legionella by the PMA-qPCR method we obtained a greater inhibition of the amplification of the 400-bp 16S gene fragment (Δlog(10) = 3.74 ± 0.39 log(10) GU ml(-1)). A complete inhibition of the PCR signal was obtained when heat-killed cells in a concentration below 1 × 10(5) cells ml(-1) were pretreated with PMA. Analysing short amplicon sizes led to only 2.08 log reductions in the Legionella dead-cell signal. When we tested environmental water samples, the two qPCR assays were in good agreement according to the kappa index (0.741). Applying qPCR combined with PMA treatment, we also obtained a good agreement (kappa index 0.615). The comparison of quantitative results shows that both assays yielded the same quantification sensitivity (mean log = 4.59 vs mean log = 4.31). Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Expression and use of the green fluorescent protein as a reporter system in Legionella pneumophila.

    PubMed

    Köhler, R; Bubert, A; Goebel, W; Steinert, M; Hacker, J; Bubert, B

    2000-01-01

    The gene encoding the green fluorescent protein (GFP) was used as a reporter gene in Legionella pneumophila. To analyze GFP expression in Legionella, transcriptional fusions of gfp with the Legionella-specific mip (Macrophage Infectivity Potentiator) promoter (P(mip)) and the sod (SuperOxide Dismutase) promoter (P(sod)) derived from Listeria monocytogenes were constructed. Following transformation into the virulent L. pneumophila strain JR 32, strong GFP-mediated fluorescence was detected with both plasmids, although the sod promoter was associated with a 1ten-fold higher intensity. No fluorescence was observed in L. pneumophila transformed with the promoterless gfp gene. Comparison of fluorescence yields between various L. pneumophila strains that differ in their virulence characteristics and were transformed with the P(mip)-gfp carrying plasmid revealed no differences in GFP expression. Infection studies using Acanthamoeba castellanii as host and recombinant L. pneumophila strains carrying the P(mip)-gfp and P(sod)-gfp fusions indicated that the mip promoter was expressed when the bacteria replicated intracellularly. GFP expression was also used to monitor, in infected A. castellanii cells, the intracellular survival of, and incidence of host-cell killing by. L. pneumophila strains that vary in their virulence properties. As quantified by flow cytometry the highly virulent L. pneumophila strain Corby was twice as infectious to A. castellanii as the Philadelphia strain JR 32. Using the avirulent Philadelphia derivative 25D invasion but no intracellular multiplication was observed. In addition, we examined by flow cytometry the influence of cytochalasin D, cycloheximide, and methylamine on the uptake of Legionella by A. castellanii. In conclusion, gfp appears to be a convenient reporter gene whose expression in Legionella can be followed in real time and allows analysis of promoter activities in Legionella and monitoring of the infection process.

  1. Polyvalent heat-killed antigen for the diagnosis of infection with Legionella pneumophila.

    PubMed Central

    Fallon, R J; Abraham, W H

    1982-01-01

    A polyvalent antigen composed of heat-killed agar-grown Legionella pneumophila serogroups 1-4 suspended in a suspension of yolk-sac from embryonated hens' eggs has been examined for use in the indirect fluorescent antibody test for Legionella infection. The serological response detected by monovalent antigen correlated well with that detected by polyvalent antigen. The use of polyvalent antigen forms a useful screening test for the detection of antibody to L pneumophila, but positive results must be confirmed by test using monovalent antigen. PMID:7042762

  2. Widespread molecular detection of Legionella pneumophila Serogroup 1 in cold water taps across the United States

    EPA Science Inventory

    In the United States 3,522 cases of legionellosis were reported to the Center for Disease Control and Prevention in 2009. Of these reports, it is estimated that 84% are caused by the microorganism Legionella pneumophila Serogroup (Sg) 1. Legionella spp. have been isolated and r...

  3. Community-acquired Legionnaires' disease caused by Legionella pneumophila serogroup 10 linked to the private home.

    PubMed

    Lück, Paul Christian; Schneider, Thomas; Wagner, Jutta; Walther, Ilona; Reif, Ursula; Weber, Stefan; Weist, Klaus

    2008-02-01

    We describe the case of a 66-year-old man with a culture-proven Legionella pneumonia after kidney transplantation. The patient developed the infection 15 days after discharge from a university hospital. Legionella pneumonia caused by Legionella pneumophila serogroup 5/10 was established by positive direct fluorescence assay, positive urinary-antigen detection and isolation of the causative agent. The infection was successfully treated by giving appropriate antibiotics, but the further course was complicated by invasive aspergillosis, cytomegalovirus pneumonia, failure of the transplanted kidney and development of septic anaemia. Four months after the diagnosis of Legionella pneumonia the patient died of multi-organ failure. The microbiological and epidemiological investigation revealed that strains from the water supply of the patient's private home were indistinguishable from the patient's isolate by amplified fragment length polymorphism analysis and sequence-based typing (SBT). Unrelated strains of serogroups 4, 5, 8 and 10 from the Dresden strain collection were of different SBT types. Thus, SBT is a very useful tool for epidemiological investigation of infections by L. pneumophila serogroups other than serogroup 1.

  4. Effects of holding time and measurement error on culturing Legionella in environmental water samples.

    PubMed

    Flanders, W Dana; Kirkland, Kimberly H; Shelton, Brian G

    2014-10-01

    Outbreaks of Legionnaires' disease require environmental testing of water samples from potentially implicated building water systems to identify the source of exposure. A previous study reports a large impact on Legionella sample results due to shipping and delays in sample processing. Specifically, this same study, without accounting for measurement error, reports more than half of shipped samples tested had Legionella levels that arbitrarily changed up or down by one or more logs, and the authors attribute this result to shipping time. Accordingly, we conducted a study to determine the effects of sample holding/shipping time on Legionella sample results while taking into account measurement error, which has previously not been addressed. We analyzed 159 samples, each split into 16 aliquots, of which one-half (8) were processed promptly after collection. The remaining half (8) were processed the following day to assess impact of holding/shipping time. A total of 2544 samples were analyzed including replicates. After accounting for inherent measurement error, we found that the effect of holding time on observed Legionella counts was small and should have no practical impact on interpretation of results. Holding samples increased the root mean squared error by only about 3-8%. Notably, for only one of 159 samples, did the average of the 8 replicate counts change by 1 log. Thus, our findings do not support the hypothesis of frequent, significant (≥= 1 log10 unit) Legionella colony count changes due to holding. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. Legionella micdadei prosthetic valve endocarditis complicated by brain abscess: case report and review of the literature.

    PubMed

    Fukuta, Yuriko; Yildiz-Aktas, Isil Z; William Pasculle, A; Veldkamp, Peter J

    2012-06-01

    Legionella endocarditis is extremely uncommon, and embolic phenomena have never been reported. We report the first case of Legionella micdadei prosthetic valve endocarditis complicated by brain abscess. A 57-y-old immunocompromised woman with a history of mitral valve replacement developed confusion and left-sided weakness. Brain magnetic resonance imaging showed a 3-cm peripheral-enhancing mass. Transoesophageal echocardiography suggested a perivalvular abscess. Blood cultures and valve cultures were negative. She was diagnosed with 16S rRNA polymerase chain reaction and silver stain, and was discharged with levofloxacin after a redo mitral valve replacement. Twelve cases of Legionella endocarditis were reviewed. Only one case had a native valve, and her endocarditis occurred after pneumonia. All cases were cured. The duration of antibiotic therapy was variable. Legionella species should be considered in the differential diagnosis of culture-negative endocarditis in both immunocompetent and immunocompromised patients. Molecular techniques and silver impregnation stains are useful, especially when cultures using buffered charcoal-yeast extract agar are negative.

  6. Contamination of the cold water distribution system of health care facilities by Legionella pneumophila: do we know the true dimension?

    PubMed

    Arvand, M; Jungkind, K; Hack, A

    2011-04-21

    German water guidelines do not recommend routine assessment of cold water for Legionella in healthcare facilities, except if the water temperature at distal sites exceeds 25°C. This study evaluates Legionella contamination in cold and warm water supplies of healthcare facilities in Hesse, Germany, and analyses the relationship between cold water temperature and Legionella contamination. Samples were collected from four facilities, with cases of healthcare-associated Legionnaires' disease or notable contamination of their water supply. Fifty-nine samples were from central lines and 625 from distal sites, comprising 316 cold and 309 warm water samples. Legionella was isolated from central lines in two facilities and from distal sites in four facilities. 17% of all central and 32% of all distal samples were contaminated. At distal sites, cold water samples were more frequently contaminated with Legionella (40% vs 23%, p <0.001) and with higher concentrations of Legionella (≥1,000 colony-forming unit/100 ml) (16% vs 6%, p<0.001) than warm water samples. There was no clear correlation between the cold water temperature at sampling time and the contamination rate. 35% of cold water samples under 20 °C at collection were contaminated. Our data highlight the importance of assessing the cold water supply of healthcare facilities for Legionella in the context of an intensified analysis.

  7. Legionella pneumophila community-acquired pneumonia (CAP) in a post-splenectomy patient with myelodysplastic syndrome (MDS).

    PubMed

    Cunha, Burke A; Hage, Jean E

    2012-01-01

    Legionnaire's disease is a cause of community-acquired pneumonia (CAP) in normal hosts, but those with impaired cell-mediated immunity (CMI) and T-lymphocyte function are particularly predisposed to Legionella species CAP. Myelodysplastic syndrome (MDS) is a disorder of the elderly that is associated with impaired CMI. Cases of MDS or Legionella species CAP are rare. Splenectomized patients primarily have impaired humoral immunity and B-lymphocyte function, and, to a lesser extent, some decrease in CMI. For this reason, Legionnaire's disease has rarely been reported in splenectomized patients. We believe this to be the first reported case of Legionella pneumophila CAP in an asplenic patient with MDS. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Quantification of viable and non-viable Legionella spp. by heterogeneous asymmetric recombinase polymerase amplification (haRPA) on a flow-based chemiluminescence microarray.

    PubMed

    Kober, Catharina; Niessner, Reinhard; Seidel, Michael

    2018-02-15

    Increasing numbers of legionellosis outbreaks within the last years have shown that Legionella are a growing challenge for public health. Molecular biological detection methods capable of rapidly identifying viable Legionella are important for the control of engineered water systems. The current gold standard based on culture methods takes up to 10 days to show positive results. For this reason, a flow-based chemiluminescence (CL) DNA microarray was developed that is able to quantify viable and non-viable Legionella spp. as well as Legionella pneumophila in one hour. An isothermal heterogeneous asymmetric recombinase polymerase amplification (haRPA) was carried out on flow-based CL DNA microarrays. Detection limits of 87 genomic units (GU) µL -1 and 26GUµL -1 for Legionella spp. and Legionella pneumophila, respectively, were achieved. In this work, it was shown for the first time that the combination of a propidium monoazide (PMA) treatment with haRPA, the so-called viability haRPA, is able to identify viable Legionella on DNA microarrays. Different proportions of viable and non-viable Legionella, shown with the example of L. pneumophila, ranging in a total concentration between 10 1 to 10 5 GUµL -1 were analyzed on the microarray analysis platform MCR 3. Recovery values for viable Legionella spp. were found between 81% and 133%. With the combination of these two methods, there is a chance to replace culture-based methods in the future for the monitoring of engineered water systems like condensation recooling plants. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. First report of Legionella pneumophila in car cabin air filters. Are these a potential exposure pathway for professional drivers?

    PubMed

    Alexandropoulou, Ioanna G; Konstantinidis, Theocharis G; Parasidis, Theodoros A; Nikolaidis, Christos; Panopoulou, Maria; Constantinidis, Theodoros C

    2013-12-01

    Recent findings have identified professional drivers as being at an increased risk of Legionnaires' disease. Our hypothesis was that used car cabin air filters represent a reservoir of Legionella bacteria, and thus a potential pathway for contamination. We analysed used cabin air filters from various types of car. The filters were analysed by culture and by molecular methods. Our findings indicated that almost a third of air filters were colonized with Legionella pneumophila. Here, we present the first finding of Legionella spp. in used car cabin air filters. Further investigations are needed in order to confirm this exposure pathway. The presence of Legionella bacteria in used cabin air filters may have been an unknown source of infection until now.

  10. Impact of drinking water conditions and copper materials on downstream biofilm microbial communities and legionella pneumophila colonization

    EPA Science Inventory

    Legionella pneumophila, the medically important species within the genus Legionella, is a concern in engineered water systems. Its ability to amplify within free-living amoebae is well documented, but its interactions/ecology within the microbial community of drinking water biofi...

  11. A comparison of assays measuring the viability of Legionella pneumophila after treatment with copper and silver ions

    EPA Science Inventory

    Background: The relatively high prevalence of Legionella pneumophila in premise plumbing systems has been widely reported. Published reports indicate Legionella has a comparatively high resistance to chlorine and moreover has the ability to grow in phagocytic amoeba which could p...

  12. Pathogen vacuole purification from legionella-infected amoeba and macrophages.

    PubMed

    Hoffmann, Christine; Finsel, Ivo; Hilbi, Hubert

    2013-01-01

    Legionella pneumophila replicates intracellularly in environmental and immune phagocytes within a unique membrane-bound compartment, the Legionella-containing vacuole (LCV). Formation of LCVs is strictly dependent on the Icm/Dot type IV secretion system and the translocation of "effector" proteins into the cell. Some effector proteins decorate the LCV membrane and subvert host cell vesicle trafficking pathways. Here we describe a method to purify intact LCVs from Dictyostelium discoideum amoebae and RAW 264.7 murine macrophages. The method comprises a two-step protocol: first, LCVs are enriched by immuno-magnetic separation using an antibody against a bacterial effector protein specifically localizing to the LCV membrane, and second, the LCVs are further purified by density gradient centrifugation. The purified LCVs can be characterized by proteomics and other biochemical approaches.

  13. Bath water contamination with Legionella and nontuberculous mycobacteria in 24-hour home baths, hot springs, and public bathhouses of Nagano Prefecture, Japan.

    PubMed

    Kobayashi, Michiko; Oana, Kozue; Kawakami, Yoshiyuki

    2014-01-01

    Bath water samples were collected from 116 hot springs, 197 public bathhouses, and 38 24-hour home baths in Nagano Prefecture, Japan, during the period of April 2009 to November 2011, for determining the presence and extent of contamination with Legionella and nontuberculous mycobacteria. Cultures positive for Legionella were observed in 123 of the 3,314 bath water samples examined. The distribution and abundance of Legionella and/or combined contamination with Legionella and nontuberculous mycobacteria were investigated to clarify the contamination levels. The abundance of Legionella was demonstrated to correlate considerably with the levels of combined contamination with Legionella and nontuberculous mycobacteria. Legionella spp. were obtained from 61% of the water samples from 24-hour home baths, but only from 3% of the samples from public bathhouses and hot springs. This is despite the fact that a few outbreaks of Legionnaires' disease in Nagano Prefecture as well as other regions of Japan have been traced to bath water contamination. The comparatively higher rate of contamination of the 24-hour home baths is a matter of concern. It is therefore advisable to routinely implement good maintenance of the water basins, particularly of the 24-hour home baths.

  14. Introduction of Monochloramine into a Municipal Water System: Impact on Colonization of Buildings by Legionella spp.

    PubMed Central

    Moore, Matthew R.; Pryor, Marsha; Fields, Barry; Lucas, Claressa; Phelan, Maureen; Besser, Richard E.

    2006-01-01

    Legionnaires' disease (LD) outbreaks are often traced to colonized potable water systems. We collected water samples from potable water systems of 96 buildings in Pinellas County, Florida, between January and April 2002, during a time when chlorine was the primary residual disinfectant, and from the same buildings between June and September 2002, immediately after monochloramine was introduced into the municipal water system. Samples were cultured for legionellae and amoebae using standard methods. We determined predictors of Legionella colonization of individual buildings and of individual sampling sites. During the chlorine phase, 19 (19.8%) buildings were colonized with legionellae in at least one sampling site. During the monochloramine phase, six (6.2%) buildings were colonized. In the chlorine phase, predictors of Legionella colonization included water source (source B compared to all others, adjusted odds ratio [aOR], 6.7; 95% confidence interval [CI], 2.0 to 23) and the presence of a system with continuously circulating hot water (aOR, 9.8; 95% CI, 1.9 to 51). In the monochloramine phase, there were no predictors of individual building colonization, although we observed a trend toward greater effectiveness of monochloramine in hotels and single-family homes than in county government buildings. The presence of amoebae predicted Legionella colonization at individual sampling sites in both phases (OR ranged from 15 to 46, depending on the phase and sampling site). The routine introduction of monochloramine into a municipal drinking water system appears to have reduced colonization by Legionella spp. in buildings served by the system. Monochloramine may hold promise as community-wide intervention for the prevention of LD. PMID:16391067

  15. Evaluation of a new monochloramine generation system for controlling Legionella in building hot water systems.

    PubMed

    Duda, Scott; Kandiah, Sheena; Stout, Janet E; Baron, Julianne L; Yassin, Mohamed; Fabrizio, Marie; Ferrelli, Juliet; Hariri, Rahman; Wagener, Marilyn M; Goepfert, John; Bond, James; Hannigan, Joseph; Rogers, Denzil

    2014-11-01

    To evaluate the efficacy of a new monochloramine generation system for control of Legionella in a hospital hot water distribution system. A 495-bed tertiary care hospital in Pittsburgh, Pennsylvania. The hospital has 12 floors covering approximately 78,000 m(2). The hospital hot water system was monitored for a total of 29 months, including a 5-month baseline sampling period prior to installation of the monochloramine system and 24 months of surveillance after system installation (postdisinfection period). Water samples were collected for microbiological analysis (Legionella species, Pseudomonas aeruginosa, Stenotrophomonas maltophilia, Acinetobacter species, nitrifying bacteria, heterotrophic plate count [HPC] bacteria, and nontuberculous mycobacteria). Chemical parameters monitored during the investigation included monochloramine, chlorine (free and total), nitrate, nitrite, total ammonia, copper, silver, lead, and pH. A significant reduction in Legionella distal site positivity was observed between the pre- and postdisinfection periods, with positivity decreasing from an average of 53% (baseline) to an average of 9% after monochloramine application (P<0.5]). Although geometric mean HPC concentrations decreased by approximately 2 log colony-forming units per milliliter during monochloramine treatment, we did not observe significant changes in other microbial populations. This is the first evaluation in the United States of a commercially available monochloramine system installed on a hospital hot water system for Legionella disinfection, and it demonstrated a significant reduction in Legionella colonization. Significant increases in microbial populations or other negative effects previously associated with monochloramine use in large municipal cold water systems were not observed.

  16. Legionella detection and subgrouping in water air-conditioning cooling tower systems in Kuwait.

    PubMed

    Al-Matawah, Qadreyah; Al-Zenki, Sameer; Al-Azmi, Ahmad; Al-Waalan, Tahani; Al-Salameen, Fadila; Hejji, Ahmad Ben

    2015-07-01

    The main aim of the study was to test for the presence of Legionnaires' disease-causing microorganisms in air-conditioned buildings in Kuwait using molecular technologies. For this purpose, 547 samples were collected from 38 cooling towers for the analysis of Legionella pneumophila. These samples included those from water (n = 178), air (n = 231), and swabs (n = 138). Out of the 547 samples, 226 (41%) samples were presumptive positive for L. pneumophila, with L. pneumophila viable counts in the positive water samples ranging from 1 to 88 CFU/ml. Of the Legionella culture-positive samples, 204 isolates were examined by latex agglutination. These isolates were predominately identified as L. pneumophila serogroup (sg) 2-14. Using the Dresden panel of monoclonal antibodies, 74 representatives isolates were further serogrouped. Results showed that 51% of the isolates belonged to serogroup 7 followed by 1 (18%) and 3 (18%). Serogroups 4 (4%) and 10 (7%) were isolated at a lower frequency, and two isolates could not be assigned to a serogroup. These results indicate the wide prevalence of L. pneumophila serogroup 7 as the predominant serogroup at the selected sampling sites. Furthermore, the 74 L. pneumophila (sg1 = 13; sg3 = 13; sg4 = 3; sg7 = 38; sg10 = 5; sgX = 2) isolates were genotyped using the seven gene protocol sequence-based typing (SBT) scheme developed by the European Working Group for Legionella Infections (EWGLI). The results show that Legionella isolates were discriminated into nine distinct sequence typing (ST) profiles, five of which were new to the SBT database of EWGLI. Additionally, all of the ST1 serogroup 1 isolates were of the OLDA/Oxford subgroup. These baseline data will form the basis for the development of a Legionella environmental surveillance program and used for future epidemiological investigations.

  17. [Disinfectants and main sanitary and preventive measures for protection of ventilation and air-conditioning systems from Legionella contamination].

    PubMed

    Gerasimov, V N; Golov, E A; Khramov, M V; Diatlov, I A

    2008-01-01

    The study was devoted to selection and assessment of disinfecting preparations for prevention of contamination by Legionella. Using system of criteria for quality assessment of disinfectants, seven newdomestic ones belonging to quaternary ammonium compounds class or to oxygen-containing preparations and designed for disinfecting of air-conditioning and ventilation systems were selected. Antibacterial and disinfecting activities of working solutions of disinfectants were tested in laboratory on the test-surfaces and test-objects of premises' air-conditioning and ventilation systems contaminated with Legionella. High antimicrobial and disinfecting activity of new preparations "Dezactiv-M", "ExtraDez", "Emital-Garant", "Aquasept Plus", "Samarovka", "Freesept", and "Ecobreeze Oxy" during their exposure on objects and materials contaminated with Legionella was shown. Main sanitary and preventive measures for defending of air-conditioning and ventilation systems from contamination by Legionella species were presented.

  18. Legionella pneumonia in the Niagara Region, Ontario, Canada: a case series.

    PubMed

    Cargnelli, Stephanie; Powis, Jeff; Tsang, Jennifer L Y

    2016-12-01

    Legionella pneumophila, a major cause of Legionnaires' disease, accounts for 2-15 % of all community-acquired pneumonia requiring hospitalization and up to 30 % of community-acquired pneumonia requiring intensive care unit admission. Early initiation of appropriate antimicrobial therapy is a crucial step in the prevention of morbidity and mortality. However, recognition of Legionnaires' disease continues to be challenging because of its nonspecific clinical features. We sought to describe hospitalized community-acquired Legionnaires' disease to increase awareness of this important and potentially lethal disease. A retrospective multicenter observational study was conducted with all patients with confirmed Legionnaires' disease in the Niagara Region of the Province of Ontario, Canada, from June to December 2013. From June to December 2013, there were 14 hospitalized cases of Legionnaires' disease in the Niagara Region. Of these, 86 % (12 patients) had at least one comorbidity and 71 % (10 patients) were cigarette smokers. In our cohort, Legionnaires' disease was diagnosed with a combination of a urinary Legionella antigen test and a Legionella real-time polymerase chain reaction assay. Delay in effective antimicrobial therapy in the treatment of Legionella infection led to clinical deterioration. The majority of patients had met systemic inflammatory response syndrome criteria with fever >38 °C (71 %), heart rate >90 beats per minute (71 %), and respiratory rate >20 breaths per minute (86 %). Eleven patients (79 %) required admission to the intensive care unit or step-down unit, and nine patients (64 %) required intubation. Clinical improvement after initiation of antimicrobials was protracted. Legionnaires' disease should be considered during the late spring and summer months in patients with a history of tobacco use and various comorbidities. Clinically, patients presented with severe, nonspecific, multisystem disease characterized by shortness of

  19. [The hazards of hospitals and selected public buildings of Legionella pneumophila].

    PubMed

    Sikora, Agnieszka; Kozioł-Montewka, Maria; Wójtowicz-Bobin, Małgorzata; Gładysz, Iwona; Dobosz, Paulina

    2013-11-01

    The registered infection and outbreaks of epidemic tend to monitor potential reservoirs of Legionella infection. According to the Act of 29 March 2007 on the requirements for the quality of water intended for human consumption are required to test for the presence and number of Legionella in the water system of hospitals. In case of detection of L. pneumophila serogroup 1 (SG 1) or increased above normal number other serogroups of bacteria it is necessary to eradicate these bacteria from the water system. The aim of this study was to assess the degree of contamination of the water supply system of selected public buildings and analyze the effectiveness of disinfection methods for the elimination of L. pneumophila in hot water systems. The materials for this study were hot and cold water samples which were collected from the water supply system of 23 different objects. Enumeration of Legionella bacteria in water samples was determined by membrane filtration (FM) and/or by surface inoculation methods according to the standards: PN-ISO 11731: 2002: "The quality of the water. Detection and enumeration of Legionella" and PN-EN ISO 11731-2: 2008: "Water quality--Detection and enumeration of Legionella--Part 2: Methodology of membrane filtration for water with a small number of bacteria". L. pneumophila was present in 164 samples of hot water, which accounted for 76.99%. In all tested water samples L. pneumophila SG 2-14 strains were detected. The most virulent strain--L. pneumophila SG 1 was not detected. In examined 23 objects in 12 of L. pneumophila exceed acceptable levels > 100 CFU/100 ml. The presence of L. pneumophila SG 2-14 demonstrated in all examined objects, indicating the risk of infection, and the need for permanent monitoring of the water system supply. The thermal disinfection is the most common, inexpensive, and effective method of control of L. pneumophila used in examined objects, but does not eliminate bacterial biofilm. Disinfection using the filters

  20. Molecular detection of Acanthamoeba spp., Naegleria fowleri and Vermamoeba (Hartmannella) vermiformis as vectors for Legionella spp. in untreated and solar pasteurized harvested rainwater.

    PubMed

    Dobrowsky, Penelope H; Khan, Sehaam; Cloete, Thomas E; Khan, Wesaal

    2016-10-10

    Legionella spp. employ multiple strategies to adapt to stressful environments including the proliferation in protective biofilms and the ability to form associations with free-living amoeba (FLA). The aim of the current study was to identify Legionella spp., Acanthamoeba spp., Vermamoeba (Hartmannella) vermiformis and Naegleria fowleri that persist in a harvested rainwater and solar pasteurization treatment system. Pasteurized (45 °C, 65 °C, 68 °C, 74 °C, 84 °C and 93 °C) and unpasteurized tank water samples were screened for Legionella spp. and the heterotrophic plate count was enumerated. Additionally, ethidium monoazide quantitative polymerase chain reaction (EMA-qPCR) was utilized for the quantification of viable Legionella spp., Acanthamoeba spp., V. vermiformis and N. fowleri in pasteurized (68 °C, 74 °C, 84 °C and 93 °C) and unpasteurized tank water samples, respectively. Of the 82 Legionella spp. isolated from unpasteurized tank water samples, Legionella longbeachae (35 %) was the most frequently isolated, followed by Legionella norrlandica (27 %) and Legionella rowbothamii (4 %). Additionally, a positive correlation was recorded between the heterotrophic plate count vs. the number of Legionella spp. detected (ρ = 0.710, P = 0.048) and the heterotrophic plate count vs. the number of Legionella spp. isolated (ρ = 0.779, P = 0.0028) from the tank water samples collected. Solar pasteurization was effective in reducing the gene copies of viable V. vermiformis (3-log) and N. fowleri (5-log) to below the lower limit of detection at temperatures of 68-93 °C and 74-93 °C, respectively. Conversely, while the gene copies of viable Legionella and Acanthamoeba were significantly reduced by 2-logs (P = 0.0024) and 1-log (P = 0.0015) overall, respectively, both organisms were still detected after pasteurization at 93 °C. Results from this study indicate that Acanthamoeba spp. primarily acts as the vector and aids in

  1. Cultural and Molecular Evidence of Legionella spp. Colonization in Dental Unit Waterlines: Which Is the Best Method for Risk Assessment?

    PubMed

    Ditommaso, Savina; Giacomuzzi, Monica; Ricciardi, Elisa; Zotti, Carla M

    2016-02-06

    Legionella spp. are ubiquitous in aquatic habitats and water distribution systems, including dental unit waterlines (DUWLs). The aim of the present study was to determine the prevalence of Legionella in DUWLs and tap water samples using PMA-qPCR and standard culture methods. The total viable counts (TVCs) of aerobic heterotrophic bacteria in the samples were also determined. Legionella spp. were detected and quantified using the modified ISO 11731 culture method. Extracted genomic DNA was analysed using the iQ-Check Quanti Legionella spp. kit, and the TVCs were determined according to the ISO protocol 6222. Legionella spp. were detected in 100% of the samples using the PMA-qPCR method, whereas these bacteria were detected in only 7% of the samples using the culture method. The number of colony forming units (CFUs) of the TVCs in the DUWL and tap water samples differed, with the bacterial load being significantly lower in the tap water samples (p-value = 0). The counts obtained were within the Italian standard range established for potable water in only 5% of the DUWL water samples and in 77% of the tap water samples. Our results show that the level of Legionella spp. contamination determined using the culture method does not reflect the true scale of the problem, and consequently we recommend testing for the presence of aerobic heterotrophic bacteria based on the assumption that Legionella spp. are components of biofilms.

  2. Cultural and Molecular Evidence of Legionella spp. Colonization in Dental Unit Waterlines: Which Is the Best Method for Risk Assessment?

    PubMed Central

    Ditommaso, Savina; Giacomuzzi, Monica; Ricciardi, Elisa; Zotti, Carla M.

    2016-01-01

    Legionella spp. are ubiquitous in aquatic habitats and water distribution systems, including dental unit waterlines (DUWLs). The aim of the present study was to determine the prevalence of Legionella in DUWLs and tap water samples using PMA-qPCR and standard culture methods. The total viable counts (TVCs) of aerobic heterotrophic bacteria in the samples were also determined. Legionella spp. were detected and quantified using the modified ISO 11731 culture method. Extracted genomic DNA was analysed using the iQ-Check Quanti Legionella spp. kit, and the TVCs were determined according to the ISO protocol 6222. Legionella spp. were detected in 100% of the samples using the PMA-qPCR method, whereas these bacteria were detected in only 7% of the samples using the culture method. The number of colony forming units (CFUs) of the TVCs in the DUWL and tap water samples differed, with the bacterial load being significantly lower in the tap water samples (p-value = 0). The counts obtained were within the Italian standard range established for potable water in only 5% of the DUWL water samples and in 77% of the tap water samples. Our results show that the level of Legionella spp. contamination determined using the culture method does not reflect the true scale of the problem, and consequently we recommend testing for the presence of aerobic heterotrophic bacteria based on the assumption that Legionella spp. are components of biofilms. PMID:26861373

  3. Mistaken identity: Legionella micdadei appearing as acid-fast bacilli on lung biopsy of a hematopoietic stem cell transplant patient.

    PubMed

    Waldron, P R; Martin, B A; Ho, D Y

    2015-02-01

    Legionella micdadei is a potential cause of invasive lung infections in immunocompromised hosts. On biopsy specimens, it can appear as an acid-fast bacillus (AFB) and can be mistaken for a member of genus Mycobacterium. As Legionella requires selective media to grow in culture, and the commonly used, commercially available urine antigen test for Legionella only detects Legionella pneumophila serogroup-1, but not L. micdadei, it is important to consider this organism in the differential diagnosis for AFB in immunocompromised hosts. We report a case of L. micdadei infection, which was initially treated empirically for non-tuberculous mycobacteria based on AFB staining of biopsy tissue before the final diagnosis was made. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. [Studies on Legionella-contamination to the air-conditioning cooling towers in big hotels and on its seroprevalence in the related populations in Beijing].

    PubMed

    Peng, X; Pei, H; Li, X; He, X; Yang, A; Tang, Y; Cao, R

    2000-08-01

    To understand the situation of Legionella-contamination at cooling towers of big hotel and the level of Legionella-infection among related populations in Beijing. Thirty-eight cooling towers of hotels were chosen for detection of Legionella. Four hundred and fourteen staff members from the hotels were selected as exposure group, with another 414 from general population as controls, for the detection of Legionella antibodies. Sixteen strains of Legionella pneumophila (Lp) were isolated from 21 of the 38 cooling towers, and the predominant strain was Lp serum group 1 (50%, 8/16). The seroprevalence of Lp antibodies for the exposure group was 9.9% (41/414), comparing to 3.5% (14/414) from the control group. The difference was statistically significant (chi(2) = 14.2, P < 0.01). Legionella was discovered in air-conditioning cooling tower of the hotels, which threatened the health to the population exposed to it.

  5. Antibiotic susceptibility of Legionella strains isolated from public water sources in Macau and Guangzhou.

    PubMed

    Xiong, Lina; Yan, He; Shi, Lei; Mo, Ziyao

    2016-12-01

    The purpose of this study was to investigate the susceptibility of waterborne strains of Legionella to eight antimicrobials commonly used in legionellosis therapy. The minimum inhibitory concentrations (MICs) of 66 environmental Legionella strains, isolated from fountains and cooling towers of public facilities (hotels, schools, and shopping malls) in Macau and Guangzhou, were tested using the microdilution method in buffered yeast extract broth. The MIC 50 /MIC 90 values for erythromycin, cefotaxime (CTX), doxycycline (DOC), minocycline (MIN), azithromycin, ciprofloxacin, levofloxacin (LEV), and moxifloxacin were 0.125/0.5 mg/L, 4/8 mg/L, 8/16 mg/L, 4/8 mg/L, 0.125/0.5 mg/L, 0.031/0.031 mg/L, 0.031/0.031 mg/L, and 0.031/0.062 mg/L, respectively. Legionella isolates were inhibited by either low concentrations of macrolides and fluoroquinolones, or high concentrations of CTX and tetracycline drugs. LEV was the most effective drug against different Legionella species and serogroups of L. pneumophila isolates. The latter were inhibited in decreasing order by MIN > CTX >DOC, while non-L. pneumophila isolates were inhibited by CTX> MIN >DOC. In this study, we evaluated drug resistance of pathogenic bacteria from the environment. This may help predict the emergence of drug resistance, improve patient outcomes, and reduce hospitalization costs.

  6. Outcome and Management of Refractory Respiratory Failure With Timely Extracorporeal Membrane OxygenationSingle-Center Experience With Legionella Pneumonia.

    PubMed

    Roncon-Albuquerque, Roberto; Vilares-Morgado, Rodrigo; van der Heijden, Gert-Jan; Ferreira-Coimbra, João; Mergulhão, Paulo; Paiva, José Artur

    2017-01-01

    To analyze the management and outcome of patients with refractory respiratory failure complicating severe Legionella pneumonia rescued with extracorporeal membrane oxygenation (ECMO) in our Center. Observational study of patients with refractory respiratory failure treated with ECMO in Hospital S.João (Porto, Portugal), between November 2009 and September 2016. A total of 112 patients rescued with ECMO, of which 14 had Legionella pneumonia. Patients with Legionella pneumonia were slightly older than patients with acute respiratory failure of other etiologies (51 [48-56] vs 45 [35-54]), but with no significant differences in acute respiratory failure severity between groups: Pao 2 /Fio 2 ratio 67 (60-75) versus 69 (55-85) and Respiratory Extracorporeal Membrane Oxygenation Survival Prediction score 4 (1-5) versus 2 (-1-4), respectively. Legionella pneumonia was associated with earlier ECMO initiation (days of invasive mechanical ventilation [IMV] before ECMO: 2.0 [1.0-4.0] vs 5.0 [2.0-9.5]). After IMV adjustment to "lung rest" settings, this group presented higher respiratory system (RS) static compliance (28.7 [18.8-37.4] vs 16.0 [10.0-20.8] mL/cmH 2 O) but required higher ECMO support (blood flow 5.0 [4.3-5.4] vs 4.2 [3.6-4.8]). Patients with Legionella pneumonia had shorter IMV (16 [14-23] vs 27 [20-42] days) and lower incidence of intensive care unit nosocomial infections (35.7% vs 64.3%), with a trend to higher hospital survival (85.7% vs 62.2%; P = .13). In Legionella pneumonia complicated by refractory respiratory failure, ECMO support allowed patient stabilization under lung protective ventilation and high survival rates. Timely ECMO referral should be considered for Legionella pneumonia failing conventional treatment.

  7. Efficacy of the detection of Legionella in hot and cold water samples by culture and PCR. I. Standardization of methods.

    PubMed

    Wójcik-Fatla, Angelina; Stojek, Nimfa Maria; Dutkiewicz, Jacek

    2012-01-01

    The aim of the present study was: - to compare methods for concentration and isolation of Legionella DNA from water; - to examine the efficacy of various modifications of PCR test (PCR, semi-nested PCR, and real-time PCR) for the detection of known numbers of Legionella pneumophila in water samples artificially contaminated with the strain of this bacterium and in randomly selected samples of environmental water, in parallel with examination by culture. It was found that filtration is much more effective than centrifugation for the concentration of DNA in water samples, and that the Qiamp DNA Mini-Kit is the most efficient for isolation of Legionella DNA from water. The semi-nested PCR and real-time PCR proved to be the most sensitive methods for detection of Legionella DNA in water samples. Both PCR modifications showed a high correlation with recovery of Legionella by culture (p<0.01), while no correlation occurred between the results of one-stage PCR and culture (p>0.1).

  8. Clinical efficacy of moxifloxacin versus comparator therapies for community-acquired pneumonia caused by Legionella spp.

    PubMed

    Garau, J; Fritsch, A; Arvis, P; Read, R C

    2010-08-01

    The aim of this study was to compare outcomes for patients with community-acquired pneumonia (CAP) caused by Legionella spp. following treatment with moxifloxacin or a range of comparator antimicrobial agents. Data were pooled from four sequential I.V./P.O. trials of moxifloxacin in the treatment of CAP. Comparators were ceftriaxone +/- erythromycin, amoxicillin/clavulanate +/- clarithromycin, trovafloxacin, levofloxacin, or ceftriaxone + levofloxacin. Legionella infection was diagnosed by culture, urine antigen testing and/or serology. Clinical success rates for the efficacy-valid (per protocol) populations were recorded at the test-of-cure visit (5-30 days post-therapy). Severity of CAP was determined using the modified American Thoracic Society criteria.Of 1786 efficacy-valid patients, 33 (1.8%) had documented infection with Legionella spp. (moxifloxacin: n=13; comparator: n=20). Of these, 30 cases were identified by serology and/or urine antigen detection and 3 by respiratory culture. The success rate of moxifloxacin vs. comparator therapy was 92.3% vs. 80.0% for the I.V./P.O. trials.Sequential (I.V./P.O.) moxifloxacin demonstrated clinical efficacy that was at least as good as that of comparator treatments for the treatment of CAP due to Legionella.

  9. Legionella pneumophila: The Paradox of a Highly Sensitive Opportunistic Waterborne Pathogen Able to Persist in the Environment

    PubMed Central

    Berjeaud, Jean-Marc; Chevalier, Sylvie; Schlusselhuber, Margot; Portier, Emilie; Loiseau, Clémence; Aucher, Willy; Lesouhaitier, Olivier; Verdon, Julien

    2016-01-01

    Legionella pneumophila, the major causative agent of Legionnaires’ disease, is found in freshwater environments in close association with free-living amoebae and multispecies biofilms, leading to persistence, spread, biocide resistance, and elevated virulence of the bacterium. Indeed, legionellosis outbreaks are mainly due to the ability of this bacterium to colonize and persist in water facilities, despite harsh physical and chemical treatments. However, these treatments are not totally efficient and, after a lag period, L. pneumophila may be able to quickly re-colonize these systems. Several natural compounds (biosurfactants, antimicrobial peptides…) with anti-Legionella properties have recently been described in the literature, highlighting their specific activities against this pathogen. In this review, we first consider this hallmark of Legionella to resist killing, in regard to its biofilm or host-associated life style. Then, we focus more accurately on natural anti-Legionella molecules described so far, which could provide new eco-friendly and alternative ways to struggle against this important pathogen in plumbing. PMID:27092135

  10. Activity of Six Essential Oils Extracted from Tunisian Plants against Legionella pneumophila.

    PubMed

    Chaftar, Naouel; Girardot, Marion; Quellard, Nathalie; Labanowski, Jérôme; Ghrairi, Tawfik; Hani, Khaled; Frère, Jacques; Imbert, Christine

    2015-10-01

    The aim of this study was to investigate the composition of six essential oils extracted from Tunisian plants, i.e., Artemisia herba-alba Asso, Citrus sinensis (L.) Osbeck, Juniperus phoenicea L., Rosmarinus officinalis L., Ruta graveolens L., and Thymus vulgaris L., and to evaluate their activity against Legionella pneumophila (microdilution assays). Eight Legionella pneumophila strains were studied, including the two well-known serogroup 1 Lens and Paris strains as controls and six environmental strains isolated from Tunisian spas belonging to serogroups 1, 4, 5, 6, and 8. The essential oils were generally active against L. pneumophila. The activities of the A. herba-alba, C. sinensis, and R. officinalis essential oils were strain-dependent, whereas those of the J. phoenicea and T. vulgaris oils, showing the highest anti-Legionella activities, with minimum inhibitory concentrations (MICs) lower than 0.03 and lower than or equal to 0.07 mg/ml, respectively, were independent of the strains' serogroup. Moreover, the microorganisms treated with T. vulgaris essential oil were shorter, swollen, and less electron-dense compared to the untreated controls. Isoborneol (20.91%), (1S)-α-pinene (18.30%) β-phellandrene (8.08%), α-campholenal (7.91%), and α-phellandrene (7.58%) were the major components isolated from the J. phoenicea oil, while carvacrol (88.50%) was the main compound of the T. vulgaris oil, followed by p-cymene (7.86%). This study highlighted the potential interest of some essential oils extracted from Tunisian plants as biocides to prevent the Legionella risk. Copyright © 2015 Verlag Helvetica Chimica Acta AG, Zürich.

  11. Investigation of Legionella Contamination in Bath Water Samples by Culture, Amoebic Co-Culture, and Real-Time Quantitative PCR Methods.

    PubMed

    Edagawa, Akiko; Kimura, Akio; Kawabuchi-Kurata, Takako; Adachi, Shinichi; Furuhata, Katsunori; Miyamoto, Hiroshi

    2015-10-19

    We investigated Legionella contamination in bath water samples, collected from 68 bathing facilities in Japan, by culture, culture with amoebic co-culture, real-time quantitative PCR (qPCR), and real-time qPCR with amoebic co-culture. Using the conventional culture method, Legionella pneumophila was detected in 11 samples (11/68, 16.2%). Contrary to our expectation, the culture method with the amoebic co-culture technique did not increase the detection rate of Legionella (4/68, 5.9%). In contrast, a combination of the amoebic co-culture technique followed by qPCR successfully increased the detection rate (57/68, 83.8%) compared with real-time qPCR alone (46/68, 67.6%). Using real-time qPCR after culture with amoebic co-culture, more than 10-fold higher bacterial numbers were observed in 30 samples (30/68, 44.1%) compared with the same samples without co-culture. On the other hand, higher bacterial numbers were not observed after propagation by amoebae in 32 samples (32/68, 47.1%). Legionella was not detected in the remaining six samples (6/68, 8.8%), irrespective of the method. These results suggest that application of the amoebic co-culture technique prior to real-time qPCR may be useful for the sensitive detection of Legionella from bath water samples. Furthermore, a combination of amoebic co-culture and real-time qPCR might be useful to detect viable and virulent Legionella because their ability to invade and multiply within free-living amoebae is considered to correlate with their pathogenicity for humans. This is the first report evaluating the efficacy of the amoebic co-culture technique for detecting Legionella in bath water samples.

  12. Investigation of Legionella Contamination in Bath Water Samples by Culture, Amoebic Co-Culture, and Real-Time Quantitative PCR Methods

    PubMed Central

    Edagawa, Akiko; Kimura, Akio; Kawabuchi-Kurata, Takako; Adachi, Shinichi; Furuhata, Katsunori; Miyamoto, Hiroshi

    2015-01-01

    We investigated Legionella contamination in bath water samples, collected from 68 bathing facilities in Japan, by culture, culture with amoebic co-culture, real-time quantitative PCR (qPCR), and real-time qPCR with amoebic co-culture. Using the conventional culture method, Legionella pneumophila was detected in 11 samples (11/68, 16.2%). Contrary to our expectation, the culture method with the amoebic co-culture technique did not increase the detection rate of Legionella (4/68, 5.9%). In contrast, a combination of the amoebic co-culture technique followed by qPCR successfully increased the detection rate (57/68, 83.8%) compared with real-time qPCR alone (46/68, 67.6%). Using real-time qPCR after culture with amoebic co-culture, more than 10-fold higher bacterial numbers were observed in 30 samples (30/68, 44.1%) compared with the same samples without co-culture. On the other hand, higher bacterial numbers were not observed after propagation by amoebae in 32 samples (32/68, 47.1%). Legionella was not detected in the remaining six samples (6/68, 8.8%), irrespective of the method. These results suggest that application of the amoebic co-culture technique prior to real-time qPCR may be useful for the sensitive detection of Legionella from bath water samples. Furthermore, a combination of amoebic co-culture and real-time qPCR might be useful to detect viable and virulent Legionella because their ability to invade and multiply within free-living amoebae is considered to correlate with their pathogenicity for humans. This is the first report evaluating the efficacy of the amoebic co-culture technique for detecting Legionella in bath water samples. PMID:26492259

  13. Assessment of relative potential for Legionella species or surrogates inhalation exposure from common water uses.

    PubMed

    Hines, Stephanie A; Chappie, Daniel J; Lordo, Robert A; Miller, Brian D; Janke, Robert J; Lindquist, H Alan; Fox, Kim R; Ernst, Hiba S; Taft, Sarah C

    2014-06-01

    The Legionella species have been identified as important waterborne pathogens in terms of disease morbidity and mortality. Microbial exposure assessment is a tool that can be utilized to assess the potential of Legionella species inhalation exposure from common water uses. The screening-level exposure assessment presented in this paper developed emission factors to model aerosolization, quantitatively assessed inhalation exposures of aerosolized Legionella species or Legionella species surrogates while evaluating two generalized levels of assumed water concentrations, and developed a relative ranking of six common in-home uses of water for potential Legionella species inhalation exposure. Considerable variability in the calculated exposure dose was identified between the six identified exposure pathways, with the doses differing by over five orders of magnitude in each of the evaluated exposure scenarios. The assessment of exposure pathways that have been epidemiologically associated with legionellosis transmission (ultrasonic and cool mist humidifiers) produced higher estimated inhalation exposure doses than pathways where epidemiological evidence of transmission has been less strong (faucet and shower) or absent (toilets and therapy pool). With consideration of the large uncertainties inherent in the exposure assessment process used, a relative ranking of exposure pathways from highest to lowest exposure doses was produced using culture-based measurement data and the assumption of constant water concentration across exposure pathways. In this ranking, the ultrasonic and cool mist humidifier exposure pathways were estimated to produce the highest exposure doses, followed by the shower and faucet exposure pathways, and then the toilet and therapy pool exposure pathways. Published by Elsevier Ltd.

  14. Legionella (Legionnaires' Disease and Pontiac Fever): Causes and Transmission

    MedlinePlus

    ... of Infection Legionella is a type of bacterium found naturally in freshwater environments, like lakes and streams. It can become a health concern when it grows and spreads in human-made building water systems like Showerheads and sink faucets Cooling towers ( ...

  15. Von Hippel-Lindau Disease

    MedlinePlus

    What is Von Hippel-Lindau disease (VHL)? Von Hippel-Lindau disease (VHL) is a rare disease that causes tumors and cysts to grow in your body. They ... can become cancerous. What causes Von Hippel-Lindau disease (VHL)? Von Hippel-Lindau disease (VHL) is a ...

  16. Modelling characteristics to predict Legionella contamination risk - Surveillance of drinking water plumbing systems and identification of risk areas.

    PubMed

    Völker, Sebastian; Schreiber, Christiane; Kistemann, Thomas

    2016-01-01

    For the surveillance of drinking water plumbing systems (DWPS) and the identification of risk factors, there is a need for an early estimation of the risk of Legionella contamination within a building, using efficient and assessable parameters to estimate hazards and to prioritize risks. The precision, accuracy and effectiveness of ways of estimating the risk of higher Legionella numbers (temperature, stagnation, pipe materials, etc.) have only rarely been empirically assessed in practice, although there is a broad consensus about the impact of these risk factors. We collected n = 807 drinking water samples from 9 buildings which had had Legionella spp. occurrences of >100 CFU/100mL within the last 12 months, and tested for Legionella spp., L. pneumophila, HPC 20°C and 36°C (culture-based). Each building was sampled for 6 months under standard operating conditions in the DWPS. We discovered high variability (up to 4 log(10) steps) in the presence of Legionella spp. (CFU/100 mL) within all buildings over a half year period as well as over the course of a day. Occurrences were significantly correlated with temperature, pipe length measures, and stagnation. Logistic regression modelling revealed three parameters (temperature after flushing until no significant changes in temperatures can be obtained, stagnation (low withdrawal, qualitatively assessed), pipe length proportion) to be the best predictors of Legionella contamination (>100 CFU/100 mL) at single outlets (precision = 66.7%; accuracy = 72.1%; F(0.5) score = 0.59). Copyright © 2015 Elsevier GmbH. All rights reserved.

  17. [Identification of Systemic Contaminations with Legionella Spec. in Drinking Water Plumbing Systems: Sampling Strategies and Corresponding Parameters].

    PubMed

    Völker, S; Schreiber, C; Müller, H; Zacharias, N; Kistemann, T

    2017-05-01

    After the amendment of the Drinking Water Ordinance in 2011, the requirements for the hygienic-microbiological monitoring of drinking water installations have increased significantly. In the BMBF-funded project "Biofilm Management" (2010-2014), we examined the extent to which established sampling strategies in practice can uncover drinking water plumbing systems systemically colonized with Legionella. Moreover, we investigated additional parameters that might be suitable for detecting systemic contaminations. We subjected the drinking water plumbing systems of 8 buildings with known microbial contamination (Legionella) to an intensive hygienic-microbiological sampling with high spatial and temporal resolution. A total of 626 drinking hot water samples were analyzed with classical culture-based methods. In addition, comprehensive hygienic observations were conducted in each building and qualitative interviews with operators and users were applied. Collected tap-specific parameters were quantitatively analyzed by means of sensitivity and accuracy calculations. The systemic presence of Legionella in drinking water plumbing systems has a high spatial and temporal variability. Established sampling strategies were only partially suitable to detect long-term Legionella contaminations in practice. In particular, the sampling of hot water at the calorifier and circulation re-entrance showed little significance in terms of contamination events. To detect the systemic presence of Legionella,the parameters stagnation (qualitatively assessed) and temperature (compliance with the 5K-rule) showed better results. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Preferential colonization and release of Legionella pneumophila from mature drinking water biofilms grown on copper versus unplasticized polyvinylchloride coupons

    EPA Science Inventory

    Legionella persistence and amplification in premise drinking water systems is a known contributor to legionellosis outbreaks, especially in the presence of suitable eukaryotic hosts. Here we examined Legionella pneumophila behavior within drinking water biofilms grown on copper ...

  19. Effect of Prior Influenza Virus Infection on Susceptibility of AKR/J Mice and Squirrel Monkeys to Respiratory Challenge with Legionella pneumophila.

    DTIC Science & Technology

    1980-07-30

    Infection on Susceptibility of AKR/J Mice and Squirrel Monkeys to Respiratory Challenge with Legionella pneumophila RICHARD F. BERENDT U. S. Army Medical...influenza virus and Legionella pneumophila than to either agent alone. b 3 F As knowledge of Legionnaires’ disease has accumulated, the evidence...suggests that many infections occur in individuals with underlying disease. Since Legionella pneumophila appears to spread by the airborne route (5, 6, 8, 9

  20. Seasonal distribution of Legionella spp. and L. pneumophila in a river in Taiwan evaluated with culture-confirmed and direct DNA extraction methods

    NASA Astrophysics Data System (ADS)

    Tung, Min-Che; Chang, Tien-Yu; Hsu, Bing-Mu; Shen, Shu-Min; Huang, Jen-Te; Kao, Po-Min; Chiu, Yi-Chou; Fan, Cheng-Wei; Huang, Yu-Li

    2013-07-01

    In this study, we evaluated the presence and amount of Legionella in along a river in Taiwan, and the relations between seasonal distribution of Legionella spp. and geographic characteristics in the watershed were also evaluated. Water samples were pre-treated and analyzed with culture-confirmed and direct DNA extraction methods. For culture-confirmed method, water samples were cultivated through a series of selective media, and candidate colonies were confirmed by PCR. For direct DNA extraction method, direct DNA extraction was performed from pre-treated water samples. The DNA extracts were analyzed with PCR and DNA sequence analysis for species determination, quantitative PCR (qPCR) was performed to quantify Legionella concentration in the water sample. In all, 150 water samples were included in this study, with 73 (48.6%) water samples detected with Legionella spp., and 17 with L. pneumophila. Over 80% Legionella spp. detections were through direct DNA extraction method, but more than 80% L. pneumophila detections were through culture-confirmed method. While detection of Legionella spp. was done with two methods, positive results were found through only one method. Legionella spp. was detected in all seasons with detection rate ranging between 34.3-58.8% and seasonal average concentration from 1.9 × 102 to 7.1 × 103 CFU/L. Most of the L. pneumophila detections were from samples collected in fall (38.2%) and summer (6.0%), which also coincided with increased cases of Legionellosis reported through Center of Disease Control in Taiwan. The high prevalence and concentration of Legionella spp. and L. pneumophila in the surface waters should be further evaluated for potential health risks.

  1. Macrolides versus quinolones in Legionella pneumonia: results from the Community-Acquired Pneumonia Organization international study.

    PubMed

    Griffin, A T; Peyrani, P; Wiemken, T; Arnold, F

    2010-04-01

    Data supporting a quinolone or a macrolide as preferred therapy for community-acquired pneumonia (CAP) due to Legionella pneumophila are not firmly established. Some literature suggests a benefit of quinolones over macrolides. To compare time to clinical stability (TCS) and length of hospital stay (LOS) in patients with Legionella pneumonia who were treated with levofloxacin (LVX) compared to those treated with newer macrolides. An analysis of patients with Legionnaires' disease from the Community-Acquired Pneumonia Organization database was performed. Patients were diagnosed with CAP using radiographic and clinical criteria, while Legionella was detected by urinary antigen or sputum culture. All patients received a macrolide (azithromycin or clarithromycin) or LVX. TCS was defined as the time from hospital admission to candidacy for switch to oral therapy. A total of 39 patients were included for analysis. The mean TCS for the macrolide group was 5.1 days vs. 4.3 days for the LVX group (P = 0.43). The mean LOS for the macrolide group was 12.7 days vs. 8.9 days for the quinolone group (P = 0.10). LOS and TCS were not statistically different between the macrolide and the LVX groups in treating CAP due to Legionella, despite trends in both outcomes favoring LVX.

  2. A single Legionella pneumophila genotype in the freshwater system in a ship experiencing three separate outbreaks of legionellosis in 6 years.

    PubMed

    Ahlen, Catrine; Aas, Marianne; Krusnell, Jadwiga; Iversen, Ole-Jan

    2016-01-01

    Recurrent legionella outbreaks at one and the same location are common. We have identified a single Legionella pneumophila genotype associated with recurrent Legionella outbreaks over 6 years. Field emergency surveys following Legionella outbreaks were performed on a vessel in 2008, 2009 and 2013. Water samples from both the distribution and technical parts of the potable water system were analyzed with respect to L. pneumophila [Real-Time PCR, cultivation, serotyping and genotyping (PFGE)] and free-living amoebae, (FLA). Legionella pneumophila serogroup 1 was present in the ship's potable water system during every outbreak. Genotyping of the 2008 survey material showed two separate PFGE genotypes while those in 2009 and 2013 demonstrated the presence of only one of the two genotypes. FLA with intracellular L. pneumophila of the same genotype were also detected. Analyses of the freshwater system on a ship following three separate Legionella outbreaks, for L. pneumophila and FLAs, revealed a single L. pneumophila genotype and FLA (Hartmanella). It is reasonable to assume that the L. pneumophila genotype detected in the freshwater system was the causal agent in the outbreaks onboard. Persistence of an apparently low-pathogenic L. pneumophila genotype and FLA in a potable water system represent a potential risk for recurrent outbreaks.

  3. Application of EMA-qPCR as a complementary tool for the detection and monitoring of Legionella in different water systems.

    PubMed

    Qin, Tian; Tian, Zhengan; Ren, Hongyu; Hu, Guangchun; Zhou, Haijian; Lu, Jinxing; Luo, Chengwang; Liu, Zunyu; Shao, Zhujun

    2012-05-01

    Legionella are prevalent in human-made water systems and cause legionellosis in humans. Conventional culturing and polymerase chain reaction (PCR) techniques are not sufficiently accurate for the quantitative analysis of live Legionella bacteria in water samples because of the presence of viable but nonculturable cells and dead cells. Here, we report a rapid detection method for viable Legionella that combines ethidium monoazide (EMA) with quantitative real-time PCR (qPCR) and apply this method to detect Legionella in a large number of water samples from different sources. Results yielded that samples treated with 5 μg/ml EMA for 10 min and subsequently exposed to light irradiation for 5 min were optimal for detecting Legionella. EMA treatment before qPCR could block the signal from approximately 4 log(10) of dead cells. When investigating environmental water samples, the percent-positive rate obtained by EMA-qPCR was significantly higher than conventional PCR and culture methods, and slightly lower than qPCR. The bacterial count of Legionella determined by EMA-qPCR were mostly greater than those determined by culture assays and lower than those determined by qPCR. Acceptable correlations were found between the EMA-qPCR and qPCR results for cooling towers, piped water and hot spring water samples (r = 0.849, P < 0.001) and also found between the EMA-qPCR and culture results for hot spring water samples (r = 0.698, P < 0.001). The results indicate that EMA-qPCR could be used as a complementary tool for the detection and monitoring of Legionella in water systems, especially in hot spring water samples.

  4. Rapid quantification of viable Legionella in nuclear cooling tower waters using filter cultivation, fluorescent in situ hybridization and solid-phase cytometry.

    PubMed

    Baudart, J; Guillaume, C; Mercier, A; Lebaron, P; Binet, M

    2015-05-01

    To develop a rapid and sensitive method to quantify viable Legionella spp. in cooling tower water samples. A rapid, culture-based method capable of quantifying as few as 600 Legionella microcolonies per litre within 2 days in industrial waters was developed. The method combines a short cultivation step of microcolonies on GVPC agar plate, specific detection of Legionella cells by a fluorescent in situ hybridization (FISH) approach, and a sensitive enumeration using a solid-phase cytometer. Following optimization of the cultivation conditions, the qualitative and quantitative performance of the method was assessed and the method was applied to 262 nuclear power plant cooling water samples. The performance of this method was in accordance with the culture method (NF-T 90-431) for Legionella enumeration. The rapid detection of viable Legionella in water is a major concern to the effective monitoring of this pathogenic bacterium in the main water sources involved in the transmission of legionellosis infection (Legionnaires' disease). The new method proposed here appears to be a robust, efficient and innovative means for rapidly quantifying cultivable Legionella in cooling tower water samples within 48 h. © 2015 The Society for Applied Microbiology.

  5. Evaluation and Comparison of Multiple Test Methods, Including Real-time PCR, for Legionella Detection in Clinical Specimens

    PubMed Central

    Peci, Adriana; Winter, Anne-Luise; Gubbay, Jonathan B.

    2016-01-01

    Legionella is a Gram-negative bacterium that can cause Pontiac fever, a mild upper respiratory infection and Legionnaire’s disease, a more severe illness. We aimed to compare the performance of urine antigen, culture, and polymerase chain reaction (PCR) test methods and to determine if sputum is an acceptable alternative to the use of more invasive bronchoalveolar lavage (BAL). Data for this study included specimens tested for Legionella at Public Health Ontario Laboratories from 1st January, 2010 to 30th April, 2014, as part of routine clinical testing. We found sensitivity of urinary antigen test (UAT) compared to culture to be 87%, specificity 94.7%, positive predictive value (PPV) 63.8%, and negative predictive value (NPV) 98.5%. Sensitivity of UAT compared to PCR was 74.7%, specificity 98.3%, PPV 77.7%, and NPV 98.1%. Out of 146 patients who had a Legionella-positive result by PCR, only 66 (45.2%) also had a positive result by culture. Sensitivity for culture was the same using either sputum or BAL (13.6%); sensitivity for PCR was 10.3% for sputum and 12.8% for BAL. Both sputum and BAL yield similar results regardless testing methods (Fisher Exact p-values = 1.0, for each test). In summary, all test methods have inherent weaknesses in identifying Legionella; therefore, more than one testing method should be used. Obtaining a single specimen type from patients with pneumonia limits the ability to diagnose Legionella, particularly when urine is the specimen type submitted. Given ease of collection and similar sensitivity to BAL, clinicians are encouraged to submit sputum in addition to urine when BAL submission is not practical from patients being tested for Legionella. PMID:27630979

  6. Health risks from exposure to Legionella in reclaimed water aerosols: Toilet flushing, spray irrigation, and cooling towers.

    PubMed

    Hamilton, Kerry A; Hamilton, Mark T; Johnson, William; Jjemba, Patrick; Bukhari, Zia; LeChevallier, Mark; Haas, Charles N

    2018-05-01

    The use of reclaimed water brings new challenges for the water industry in terms of maintaining water quality while increasing sustainability. Increased attention has been devoted to opportunistic pathogens, especially Legionella pneumophila, due to its growing importance as a portion of the waterborne disease burden in the United States. Infection occurs when a person inhales a mist containing Legionella bacteria. The top three uses for reclaimed water (cooling towers, spray irrigation, and toilet flushing) that generate aerosols were evaluated for Legionella health risks in reclaimed water using quantitative microbial risk assessment (QMRA). Risks are compared using data from nineteen United States reclaimed water utilities measured with culture-based methods, quantitative PCR (qPCR), and ethidium-monoazide-qPCR. Median toilet flushing annual infection risks exceeded 10 -4 considering multiple toilet types, while median clinical severity infection risks did not exceed this value. Sprinkler and cooling tower risks varied depending on meteorological conditions and operational characteristics such as drift eliminator performance. However, the greatest differences between risk scenarios were due to 1) the dose response model used (infection or clinical severity infection) 2) population at risk considered (residential or occupational) and 3) differences in laboratory analytical method. Theoretical setback distances necessary to achieve a median annual infection risk level of 10 -4 are proposed for spray irrigation and cooling towers. In both cooling tower and sprinkler cases, Legionella infection risks were non-trivial at potentially large setback distances, and indicate other simultaneous management practices could be needed to manage risks. The sensitivity analysis indicated that the most influential factors for variability in risks were the concentration of Legionella and aerosol partitioning and/or efficiency across all models, highlighting the importance of

  7. The Legionella IcmS-IcmW protein complex is important for Dot/Icm-mediated protein translocation.

    PubMed

    Ninio, Shira; Zuckman-Cholon, Deborah M; Cambronne, Eric D; Roy, Craig R

    2005-02-01

    The intracellular pathogen Legionella pneumophila can infect and replicate within macrophages of a human host. To establish infection, Legionella require the Dot/Icm secretion system to inject protein substrates directly into the host cell cytoplasm. The mechanism by which substrate proteins are engaged and translocated by the Dot/Icm system is not well understood. Here we show that two cytosolic components of the Dot/Icm secretion machinery, the proteins IcmS and IcmW, play an important role in substrate translocation. Biochemical analysis indicates that IcmS and IcmW form a stable protein complex. In Legionella, the IcmW protein is rapidly degraded in the absence of the IcmS protein. Substrate proteins translocated into mammalian host cells by the Dot/Icm system were identified using the IcmW protein as bait in a yeast two-hybrid screen. It was determined that the IcmS-IcmW complex interacts with these substrates and plays an important role in translocation of these proteins into mammalian cells. These data are consistent with the IcmS-IcmW complex being involved in the recognition and Dot/Icm-dependent translocation of substrate proteins during Legionella infection of host cells.

  8. Control of Legionella Contamination and Risk of Corrosion in Hospital Water Networks following Various Disinfection Procedures

    PubMed Central

    Ferranti, Greta; Mansi, Antonella; Marcelloni, Anna M.; Proietto, Anna R.; Saini, Navneet; Borella, Paola; Bargellini, Annalisa

    2016-01-01

    Physical and chemical disinfection methods have been proposed with the aim of controlling Legionella water contamination. To date, the most effective procedures for reducing bacterial contamination have not yet been defined. The aim of this study was to assess the long-term effectiveness of various disinfection procedures in order to reduce both culturable and nonculturable (NC) legionellae in different hospital water networks treated with heat, chlorine dioxide, monochloramine, and hydrogen peroxide. The temperature levels and biocide concentrations that proved to give reliable results were analyzed. In order to study the possible effects on the water pipes, we verified the extent of corrosion on experimental coupons after applying each method for 6 months. The percentage of positive points was at its lowest after treatment with monochloramine, followed by chlorine dioxide, hydrogen peroxide, and hyperthermia. Different selections of Legionella spp. were observed, as networks treated with chlorine-based disinfectants were contaminated mainly by Legionella pneumophila serogroup 1, hyperthermia was associated with serogroups 2 to 14, and hydrogen peroxide treatment was associated mainly with non-pneumophila species. NC cells were detected only in heat-treated waters, and also when the temperature was approximately 60°C. The corrosion rates of the coupons were within a satisfactory limit for water networks, but the morphologies differed. We confirm here that chemical disinfection controls Legionella colonization more effectively than hyperthermia does. Monochloramine was the most effective treatment, while hydrogen peroxide may be a promising alternative to chlorine-based disinfectants due to its ability to select for other, less virulent or nonpathogenic species. PMID:26969696

  9. THE POTENTIAL OF IN SITU HYBRIDIZATION AND AN IMMUNOGOLD ASSAY TO IDENTIFY LEGIONELLA ASSOCIATIONS WITH OTHER MICROORGANISMS. (R825352)

    EPA Science Inventory

    Based on in vitro studies, bacteria in the genus Legionella are believed to multiply within protozoa such as amoebae in aquatic environments. Current methods used for detection of Legionella species, however, are not designed to show this relationship. Thus the natural intimate a...

  10. Legionella cardiaca sp. nov., isolated from a case of native valve endocarditis in a human heart

    PubMed Central

    Pearce, Meghan M.; Theodoropoulos, Nicole; Mandel, Mark J.; Brown, Ellen; Reed, Kurt D.

    2012-01-01

    A Gram-negative, rod-shaped bacterium, designated H63T, was isolated from aortic valve tissue of a patient with native valve endocarditis. 16S rRNA gene sequencing revealed that H63T belongs to the genus Legionella, with its closest neighbours being the type strains of Legionella brunensis (98.8 % similarity), L. londiniensis (97.0 %), L. jordanis (96.8 %), L. erythra (96.2 %), L. dresdenensis (96.0 %) and L. rubrilucens, L. feeleii, L. pneumophila and L. birminghamensis (95.7 %). DNA–DNA hybridization studies yielded values of <70 % relatedness between strain H63T and its nearest neighbours in terms of 16S rRNA gene sequence similarity, indicating that the strain represents a novel species. Phylogenetic analysis of the 16S rRNA, macrophage infectivity potentiator (mip) and RNase P (rnpB) genes confirmed that H63T represents a distinct species, with L. brunensis being its closest sister taxon. Fatty acid composition and biochemical traits, such as the inability to ferment glucose and reduce nitrate, supported the affiliation of H63T to the genus Legionella. H63T was distinguishable from its neighbours based on it being positive for hippurate hydrolysis. H63T was further differentiated by its inability to grow on BCYE agar at 17 °C, its poor growth on low-iron medium and the absence of sliding motility. Also, H63T did not react with antisera generated from type strains of Legionella species. H63T replicated within macrophages. It also grew in mouse lungs, inducing histopathological evidence of pneumonia and dissemination to the spleen. Together, these results confirm that H63T represents a novel, pathogenic Legionella species, for which the name Legionella cardiaca sp. nov. is proposed. The type strain is H63T ( = ATCC BAA-2315T  = DSM 25049T  = JCM 17854T). PMID:22286905

  11. Wernher von Braun

    NASA Image and Video Library

    1959-01-01

    This photograph of Dr. von Braun, shown here to the left of General Bruce Medaris, was taken in the fall of 1959, immediately prior to Medaris' retirement from the Army. At the time, von Braun and his associates worked for the Army Ballistics Missile Agency in Huntsville, Alabama. Those in the photograph have been identified as Ernst Stuhlinger, Frederick von Saurma, Fritz Mueller, Hermarn Weidner, E.W. Neubert (partially hidden), W.A. Mrazek, Karl Heimburg, Arthur Rudolph, Otto Hoberg, von Braun, Oswald Lange, Medaris, Helmut Hoelzer, Hans Maus, E.D. Geissler, Hans Heuter, and George Constan.

  12. Applicability assessment of ceramic microbeads coated with hydroxyapatite-binding silver/titanium dioxide ceramic composite earthplus™ to the eradication of Legionella in rainwater storage tanks for household use.

    PubMed

    Oana, Kozue; Kobayashi, Michiko; Yamaki, Dai; Sakurada, Tsukasa; Nagano, Noriyuki; Kawakami, Yoshiyuki

    2015-01-01

    Water environments appear to be the habitats of Legionella species. Legionellosis is considered as a preventable illness because bacterial reservoirs can be controlled and removed. Roof-harvested rainwater has attracted significant attention not only as a groundwater recharge but also as a potential alternative source of nonpotable water. We successfully developed ceramic microbeads coated with hydroxyapatite-binding silver/titanium dioxide ceramic composite earthplus™ using the thermal spraying method. The ceramic microbeads were demonstrated to have bactericidal activities against not only Legionella but also coliform and heterotrophic bacteria. Immersing the ceramic microbeads in household rainwater storage tanks was demonstrated to yield the favorable eradication of Legionella organisms. Not only rapid-acting but also long-lasting bactericidal activities of the ceramic microbead were exhibited against Legionella pneumophila. However, time-dependent attenuation of the bactericidal activities against Legionella were also noted in the sustainability appraisal experiment. Therefore, the problems to be overcome surely remain in constantly managing the Legionella-pollution by means of immersing the ceramic microbeads. The results of our investigation apparently indicate that the earthplus™-coated ceramic microbeads would become the favorable tool for Legionella measures in household rainwater storage tanks, which may become the natural reservoir for Legionella species. Our investigation would justify further research and data collection to obtain more reliable procedures to microbiologically regulate the Legionella in rainwater storage tanks.

  13. Applicability assessment of ceramic microbeads coated with hydroxyapatite-binding silver/titanium dioxide ceramic composite earthplus™ to the eradication of Legionella in rainwater storage tanks for household use

    PubMed Central

    Oana, Kozue; Kobayashi, Michiko; Yamaki, Dai; Sakurada, Tsukasa; Nagano, Noriyuki; Kawakami, Yoshiyuki

    2015-01-01

    Water environments appear to be the habitats of Legionella species. Legionellosis is considered as a preventable illness because bacterial reservoirs can be controlled and removed. Roof-harvested rainwater has attracted significant attention not only as a groundwater recharge but also as a potential alternative source of nonpotable water. We successfully developed ceramic microbeads coated with hydroxyapatite-binding silver/titanium dioxide ceramic composite earthplus™ using the thermal spraying method. The ceramic microbeads were demonstrated to have bactericidal activities against not only Legionella but also coliform and heterotrophic bacteria. Immersing the ceramic microbeads in household rainwater storage tanks was demonstrated to yield the favorable eradication of Legionella organisms. Not only rapid-acting but also long-lasting bactericidal activities of the ceramic microbead were exhibited against Legionella pneumophila. However, time-dependent attenuation of the bactericidal activities against Legionella were also noted in the sustainability appraisal experiment. Therefore, the problems to be overcome surely remain in constantly managing the Legionella-pollution by means of immersing the ceramic microbeads. The results of our investigation apparently indicate that the earthplus™-coated ceramic microbeads would become the favorable tool for Legionella measures in household rainwater storage tanks, which may become the natural reservoir for Legionella species. Our investigation would justify further research and data collection to obtain more reliable procedures to microbiologically regulate the Legionella in rainwater storage tanks. PMID:26346201

  14. Wernher von Braun

    NASA Image and Video Library

    1977-06-16

    Dr. Wernher von Braun served as Marshall Space Flight Center's first director from July 1, 1960 until January 27, 1970, when he was appointed NASA Deputy Associate Administrator for Planning. Following World War II, Dr. von Braun and his German colleagues arrived in the United States under Project Paper Clip to continue their rocket development work. In 1950, von Braun and his rocket team were transferred from Ft. Bliss, Texas to Huntsville, Alabama to work for the Army's rocket program at Redstone Arsenal and later, NASA's Marshall Space Flight Center. Under von Braun's leadership, Marshall developed the Saturn V launch vehicle which took Apollo astronauts to the moon. Dr. von Braun died in Alexandria, Va., on June 16, 1977, seven years after his NASA appointment. This photo was taken at the site where he was laid to rest.

  15. Bacterial community dynamics in a cooling tower with emphasis on pathogenic bacteria and Legionella species using universal and genus-specific deep sequencing.

    PubMed

    Pereira, Rui P A; Peplies, Jörg; Höfle, Manfred G; Brettar, Ingrid

    2017-10-01

    Cooling towers are the major source of outbreaks of legionellosis in Europe and worldwide. These outbreaks are mostly associated with Legionella species, primarily L. pneumophila, and its surveillance in cooling tower environments is of high relevance to public health. In this study, a combined NGS-based approach was used to study the whole bacterial community, specific waterborne and water-based bacterial pathogens, especially Legionella species, targeting the 16S rRNA gene. This approach was applied to water from a cooling tower obtained by monthly sampling during two years. The studied cooling tower was an open circuit cooling tower with lamellar cooling situated in Braunschweig, Germany. A highly diverse bacterial community was observed with 808 genera including 25 potentially pathogenic taxa using universal 16S rRNA primers. Sphingomonas and Legionella were the most abundant pathogenic genera. By applying genus-specific primers for Legionella, a diverse community with 85 phylotypes, and a representative core community with substantial temporal heterogeneity was observed. A high percentage of sequences (65%) could not be affiliated to an acknowledged species. L. pneumophila was part of the core community and the most abundant Legionella species reinforcing the importance of cooling towers as its environmental reservoir. Major temperature shifts (>10 °C) were the key environmental factor triggering the reduction or dominance of the Legionella species in the Legionella community dynamics. In addition, interventions by chlorine dioxide had a strong impact on the Legionella community composition but not on the whole bacterial community. Overall, the presented results demonstrated the value of a combined NGS approach for the molecular monitoring and surveillance of health related pathogens in man-made freshwater systems. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Molecular Detection of Legionella spp. and their associations with Mycobacterium spp., Pseudomonas aeruginosa and amoeba hosts in a drinking water distribution system.

    PubMed

    Lu, J; Struewing, I; Vereen, E; Kirby, A E; Levy, K; Moe, C; Ashbolt, N

    2016-02-01

    This study investigated waterborne opportunistic pathogens (OPs) including potential hosts, and evaluated the use of Legionella spp. for indicating microbial water quality for OPs within a full-scale operating drinking water distribution system (DWDS). To investigate the occurrence of specific microbial pathogens within a major city DWDS we examined large volume (90 l drinking water) ultrafiltration (UF) concentrates collected from six sites between February, 2012 and June, 2013. The detection frequency and concentration estimates by qPCR were: Legionella spp. (57%/85 cell equivalent, CE l(-1) ), Mycobacterium spp. (88%/324 CE l(-1) ), Pseudomonas aeruginosa (24%/2 CE l(-1) ), Vermamoeba vermiformis (24%/2 CE l(-1) ) and Acanthamoeba spp. (42%/5 cyst equivalent, CE l(-1) ). There was no detection of the following microorganisms: human faecal indicator Bacteroides (HF183), Salmonella enterica, Campylobacter spp., Escherichia coli O157:H7, Giardia intestinalis, Cryptosporidium spp. or Naegleria fowleri. There were significant correlations between the qPCR signals of Legionella spp. and Mycobacterium spp., and their potential hosts V. vermiformis and Acanthamoeba spp. Sequencing of Legionella spp. demonstrated limited diversity, with most sequences coming from two dominant groups, of which the larger dominant group was an unidentified species. Other known species including Legionella pneumophila were detected, but at low frequency. The densities of Legionella spp. and Mycobacterium spp. were generally higher (17 and 324 folds, respectively) for distal sites relative to the entry point to the DWDS. Legionella spp. occurred, had significant growth and were strongly associated with free-living amoebae (FLA) and Mycobacterium spp., suggesting that Legionella spp. could provide a useful DWDS monitoring role to indicate potential conditions for non-faecal OPs. The results provide insight into microbial pathogen detection that may aid in the monitoring of microbial water

  17. [Legionella outbreak in Amsterdam: a cooling tower as the source].

    PubMed

    van den Hoek, J A R; IJzerman, E P F; Coutinho, R A

    2006-08-19

    During the period 6-28 July 2006, 30 confirmed cases of Legionella infection were identified in Amsterdam, 2 of which were fatal. All had a positive urinary antigen test, by which Legionella pneumophila serogroup I could be demonstrated. Consultations between the parties involved in the control of infectious diseases started on July 7th, as soon as it became clear that there was an outbreak. On July 10th it was established that relatively many of these patients lived in the eastern part of the city centre. After a study of the prevailing winds during the past 3 weeks, the search for installations containing water was started. A cooling tower in the town centre was closed on July 11th by way of precaution. During the following week, this tower was proven to be the source of the outbreak.

  18. [Genotypic variability and persistence of Legionella pulsed-field gel electrophoresis patterns in 16 cooling towers in Shanghai, China].

    PubMed

    Chen, Ming-liang; Wang, Gang-yi; Chen, Min; Zhou, Hai-jian; Shao, Zhu-jun; Zhang, Xi; Wu, Fan

    2010-07-01

    To investigate the genotypic characteristics and persistence of Legionella pulsed-field gel electrophoresis (PFGE) patterns in 16 air-conditioner cooling towers in six different public sites of Shanghai. From May to October, continuous sampling was operated once per month in 2007. Legionella strains isolated from the 16 cooling towers were confirmed by serological and latex agglutination. PFGE was applied for the fingerprinting of the isolates, while the cluster results of PFGE were analyzed by BioNumerics software. 131 strains of Legionella were isolated, including L. pneumophila, L. bozemanae, L. micdadei and L. anisa. 52 distinguishable PFGE patterns were differentiated among the 16 cooling towers, with 37 patterns were owned by just one cooling tower, which was not shared with other cooling towers, while 15 patterns were shared by more than 2 cooling towers. All the cooling towers had ≥ 2 PFGE patterns, while in 13 cooling towers the same PFGE patterns were recovered during the six months. From June to October of 2007, 18 strains of Legionella belonging to the PFGE pattern of LPAs.SH0078 were isolated continuously from 6 cooling towers. This study demonstrated great genotypic diversity and complexity of Legionella in cooling towers. Persistence of the PFGE patterns was observed in 81.25% of the cooling towers. The PFGE pattern of LPAs. SH0078 was distributed widely, suggesting it might be the dominate strain in Shanghai.

  19. Pilot project for rapid Legionella testing.

    PubMed

    Pearson, Susan

    2013-08-01

    Susan Pearson BSc, a freelance journalist and communications consultant specialising in medicine and the environment (see also HEJ - April 2013), reports on discussions, at a recent educational seminar, on a pilot project undertaken by the Environmental Microbiology Unit at the Brighton and Sussex University Hospitals (BSUH) NHS Trust, which compared the effectiveness and accuracy of conventional 'culture' testing for Legionella in water systems, with a new, 'less labour-intensive', DNA-based testing system that can produce results 'in a matter of hours'.

  20. Master manipulators: an update on Legionella pneumophila Icm/Dot translocated substrates and their host targets

    PubMed Central

    Isaac, Dervla T; Isberg, Ralph

    2014-01-01

    Macrophages are the front line of immune defense against invading microbes. Microbes, however, have evolved numerous and diverse mechanisms to thwart these host immune defenses and thrive intracellularly. Legionella pneumophila, a Gram-negative pathogen of amoebal and mammalian phagocytes, is one such microbe. In humans, it causes a potentially fatal pneumonia referred to as Legionnaires' disease. Armed with the Icm/Dot type IV secretion system, which is required for virulence, and approximately 300 translocated proteins, Legionella is able to enter host cells, direct the biogenesis of its own vacuolar compartment, and establish a replicative niche, where it grows to high levels before lysing the host cell. Efforts to understand the pathogenesis of this bacterium have focused on characterizing the molecular activities of its many effectors. In this article, we highlight recent strides that have been made in understanding how Legionella effectors mediate host-pathogen interactions. PMID:24762308

  1. Wernher von Braun

    NASA Image and Video Library

    1960-01-01

    Dr. Wernher von Braun served as Marshall Space Flight Center's first director from July 1, 1960 until January 27, 1970, when he was appointed NASA Deputy Associate Administrator for Plarning. Following World War II, Dr. von Braun and his German colleagues arrived in the United States under Project Paperclip to continue their rocket development work. In 1950, von Braun and his rocket team were transferred from Ft. Bliss, Texas to Huntsville, Alabama to work for the Army's rocket program at Redstone Arsenal and later, NASA's Marshall Space Flight Center. Under von Braun's leadership, Marshall developed the Saturn V launch vehicle which took Apollo astronauts to the moon.

  2. SULFAMETHOXAZOLE-TRIMETHOPRIM TREATMENT OF GUINEA PIGS INFECTED WITH 'LEGIONELLA PNEUMPOPHILA'

    EPA Science Inventory

    Legionnaires' disease is a bacterial pneumonia caused by Legionella pneumophila. Many antibiotics inhibit the growth of L. pneumophila in vitro, but only erythromycin and rifampin have been clinically effective. Parallel results have been observed in guinea pigs infected ip with ...

  3. Legionella oakridgensis ATCC 33761 genome sequence and phenotypic characterization reveals its replication capacity in amoebae.

    PubMed

    Brzuszkiewicz, Elzbieta; Schulz, Tino; Rydzewski, Kerstin; Daniel, Rolf; Gillmaier, Nadine; Dittmann, Christine; Holland, Gudrun; Schunder, Eva; Lautner, Monika; Eisenreich, Wolfgang; Lück, Christian; Heuner, Klaus

    2013-12-01

    Legionella oakridgensis is able to cause Legionnaires' disease, but is less virulent compared to L. pneumophila strains and very rarely associated with human disease. L. oakridgensis is the only species of the family legionellae which is able to grow on media without additional cysteine. In contrast to earlier publications, we found that L. oakridgensis is able to multiply in amoebae. We sequenced the genome of L. oakridgensis type strain OR-10 (ATCC 33761). The genome is smaller than the other yet sequenced Legionella genomes and has a higher G+C-content of 40.9%. L. oakridgensis lacks a flagellum and it also lacks all genes of the flagellar regulon except of the alternative sigma-28 factor FliA and the anti-sigma-28 factor FlgM. Genes encoding structural components of type I, type II, type IV Lvh and type IV Dot/Icm, Sec- and Tat-secretion systems could be identified. Only a limited set of Dot/Icm effector proteins have been recognized within the genome sequence of L. oakridgensis. Like in L. pneumophila strains, various proteins with eukaryotic motifs and eukaryote-like proteins were detected. We could demonstrate that the Dot/Icm system is essential for intracellular replication of L. oakridgensis. Furthermore, we identified new putative virulence factors of Legionella. Copyright © 2013 Elsevier GmbH. All rights reserved.

  4. Control of Legionella Contamination and Risk of Corrosion in Hospital Water Networks following Various Disinfection Procedures.

    PubMed

    Marchesi, Isabella; Ferranti, Greta; Mansi, Antonella; Marcelloni, Anna M; Proietto, Anna R; Saini, Navneet; Borella, Paola; Bargellini, Annalisa

    2016-05-15

    Physical and chemical disinfection methods have been proposed with the aim of controlling Legionella water contamination. To date, the most effective procedures for reducing bacterial contamination have not yet been defined. The aim of this study was to assess the long-term effectiveness of various disinfection procedures in order to reduce both culturable and nonculturable (NC) legionellae in different hospital water networks treated with heat, chlorine dioxide, monochloramine, and hydrogen peroxide. The temperature levels and biocide concentrations that proved to give reliable results were analyzed. In order to study the possible effects on the water pipes, we verified the extent of corrosion on experimental coupons after applying each method for 6 months. The percentage of positive points was at its lowest after treatment with monochloramine, followed by chlorine dioxide, hydrogen peroxide, and hyperthermia. Different selections of Legionella spp. were observed, as networks treated with chlorine-based disinfectants were contaminated mainly by Legionella pneumophila serogroup 1, hyperthermia was associated with serogroups 2 to 14, and hydrogen peroxide treatment was associated mainly with non-pneumophila species. NC cells were detected only in heat-treated waters, and also when the temperature was approximately 60°C. The corrosion rates of the coupons were within a satisfactory limit for water networks, but the morphologies differed. We confirm here that chemical disinfection controls Legionella colonization more effectively than hyperthermia does. Monochloramine was the most effective treatment, while hydrogen peroxide may be a promising alternative to chlorine-based disinfectants due to its ability to select for other, less virulent or nonpathogenic species. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  5. The characterization and certification of a quantitative reference material for Legionella detection and quantification by qPCR.

    PubMed

    Baume, M; Garrelly, L; Facon, J P; Bouton, S; Fraisse, P O; Yardin, C; Reyrolle, M; Jarraud, S

    2013-06-01

    The characterization and certification of a Legionella DNA quantitative reference material as a primary measurement standard for Legionella qPCR. Twelve laboratories participated in a collaborative certification campaign. A candidate reference DNA material was analysed through PCR-based limiting dilution assays (LDAs). The validated data were used to statistically assign both a reference value and an associated uncertainty to the reference material. This LDA method allowed for the direct quantification of the amount of Legionella DNA per tube in genomic units (GU) and the determination of the associated uncertainties. This method could be used for the certification of all types of microbiological standards for qPCR. The use of this primary standard will improve the accuracy of Legionella qPCR measurements and the overall consistency of these measurements among different laboratories. The extensive use of this certified reference material (CRM) has been integrated in the French standard NF T90-471 (April 2010) and in the ISO Technical Specification 12 869 (Anon 2012 International Standardisation Organisation) for validating qPCR methods and ensuring the reliability of these methods. © 2013 The Society for Applied Microbiology.

  6. Intermittent use of copper-silver ionization for Legionella control in water distribution systems: a potential option in buildings housing individuals at low risk of infection.

    PubMed

    Liu, Z; Stout, J E; Boldin, M; Rugh, J; Diven, W F; Yu, V L

    1998-01-01

    One copper-silver ionization system was sequentially installed onto the hot-water recirculation lines of two hospital buildings colonized with Legionella pneumophila, serogroup 1. A third building with the same water supply and also colonized with Legionella served as a control. Four weeks after activation of the system, distal site positivity for Legionella in the first test building dropped to zero. After operating for 16 weeks, the system was disconnected and installed onto the second test building. Twelve weeks of disinfection reduced the distal site positivity for Legionella in the second test building to zero. Legionella recolonization did not occur in the first test building for 6-12 weeks and in the second test building for 8-12 weeks after inactivation of the system. The control building remained Legionella-positive throughout the experimental period. A significantly higher copper concentration was found in the biofilm taken from a sampling device than in that from water. This is likely to be the reason that the copper-silver ionization system had the residual effect of preventing early recolonization. Our study raises the possibility that one copper-silver unit could be rotated among several buildings to maintain a Legionella-free environment. Such an approach may be cost-effective for buildings housing individuals at low risk for contracting legionnaires' disease.

  7. Pregnancy and delivery in women with von Willebrand's disease and different von Willebrand factor mutations.

    PubMed

    Castaman, Giancarlo; Tosetto, Alberto; Rodeghiero, Francesco

    2010-06-01

    Pregnancy in von Willebrand's disease may carry a significant risk of bleeding. Information on changes in factor VIII and von Willebrand factor and pregnancy outcome in relation to von Willebrand factor gene mutations are very scanty. We examined biological response to desmopressin, changes in factor VIII and von Willebrand factor and pregnancy outcome in a cohort of 23 women with von Willebrand's disease characterized at molecular level and prospectively followed during 2000-2007. Thirty-one pregnancies occurred during the study period. Remarkably, similar changes of factor VIII and von Willebrand factor were observed after desmopressin and during pregnancy in nine women with R854Q, R1374H, V1665E, V1822G and C2362F mutations. Women with von Willebrand's disease and R1205H and C1130F mutations (17 pregnancies in 12 women) had only a slight increase of factor VIII and von Willebrand factor during pregnancy while their response to desmopressin was marked but short-lived. For these women, two to three desmopressin administrations within the first 48 hours were sufficient to successfully manage vaginal delivery. Two women with recessive von Willebrand's disease due to compound heterozygosity for different gene mutations had a spontaneous, major increase in factor VIII while von Willebrand factor remained severely reduced. Desmopressin increased factor VIII and was clinically useful in the first case, while a factor VIII/von Willebrand factor concentrate was required in the second patient not responsive to the compound. Factor VIII/von Willebrand factor concentrate was also required for two women with type 2 A von Willebrand's disease with V1665E mutations who had no von Willebrand factor activity change during pregnancy. In one of them, delayed bleeding occurred 15 days later requiring treatment with Factor VIII/von Willebrand factor concentrate. No miscarriages or stillbirths occurred. Close follow-up and detailed guidelines for the management of parturition have

  8. Wernher von Braun

    NASA Image and Video Library

    1970-02-24

    In 1970 Marshall Space Flight Center (MSFC) Director Dr. Wernher von Braun (right) was reassigned to NASA Headquarters to serve as Deputy Associate Administrator for Plarning. Prior to his transfer, Dr. von Braun was honored for his career in Huntsville, Alabama, with the celebration of "Wernher von Braun Day." Among those participating were Alabama Governor Albert Brewer (left) and Alabama Senator John Sparkman (center). (Courtesy of Huntsville/Madison County Public library)

  9. Growth of Legionella anisa in a model drinking water system to evaluate different shower outlets and the impact of cast iron rust.

    PubMed

    van der Lugt, Wilco; Euser, Sjoerd M; Bruin, Jacob P; Den Boer, Jeroen W; Walker, Jimmy T; Crespi, Sebastian

    2017-11-01

    Legionella continues to be a problem in water systems. This study investigated the influence of different shower mixer faucets, and the influence of the presence of cast iron rust from a drinking water system on the growth of Legionella. The research is conducted using a model of a household containing four drinking water systems. All four systems, which contained standard plumbing components including copper pipes and a water heater, were filled with unchlorinated drinking water. Furthermore, all systems had three different shower faucets: (A) a stainless-steel faucet, (B) a brass-ceramic faucet, and (C) a brass thermostatic faucet. System 1 was solely filled with drinking water. System 2 was filled with drinking water, and cast iron rust. System 3 was contaminated with Legionella, and system 4 was contaminated with a Legionella, and cast iron rust. During a period of 34 months, 450 cold water samples were taken from 15 sample points of the four drinking water systems, and tested for Legionella according to the Dutch Standard (NEN 6265). In system 4, with added cast iron rust, the stainless-steel mixer faucet (A) had the highest concentration of Legionella at >4.3log10CFU/l (>20,000CFU/l) and was positive in 46.4% of samples. In contrast, the stainless-steel mixer faucet (A) of system 3 without cast iron rust showed 14.3% positive samples with a maximum concentration of 3.9log10CFU/l (7600CFU/l) Legionella. Additionally, both contaminated systems (3 and 4), with the brass thermostatic faucet (C), tested positive for Legionella. System 3 in 85.7% of the samples, with a maximum concentration of 4.38log10CFU/l (24,200CFU/l), and system 4 in 64.3% of the samples with a maximum concentration of 4.13log10CFU/l (13.400CFU/l). These results suggest that both the type of faucet used in a drinking water system and the presence or absence of cast iron rust influence the growth of Legionella. Copyright © 2017 Elsevier GmbH. All rights reserved.

  10. [Community-acquired pneumonia due to Legionella pneumophila serogroup 1. Study of 97 cases].

    PubMed

    Benito, José Ramón; Montejo, José Miguel; Cancelo, Laura; Zalacaín, Rafael; López, Leyre; Fernández Gil de Pareja, Joaquín; Alonso, Eva; Oñate, Javier

    2003-10-01

    Legionella pneumophila is the causal agent of 5% to 12% of sporadic community-acquired pneumonia cases, though rates are changing with the use of new diagnostic methods. This is a retrospective study of all patients admitted to our hospital with community-acquired pneumonia due to Legionella pneumophila between 1997 and 2001. Diagnostic criteria included either a positive Legionella serogroup 1 urinary antigen test or seroconversion and a chest radiograph consistent with pneumonia. A total of 97 patients were studied. Ninety cases (92.8%) were community-acquired and 7 (7.2%) were associated with travelling. In 82 cases (84.5%) the presentation was sporadic. Seventy-five patients were smokers (77.3%). The most common symptoms were fever in 91 patients (93.8%) and cough in 67 (68.1%). In five patients (5.2%) creatine phosphokinase concentrations were over 5 times their baseline values (in two over 100 times); four of these patients presented acute renal failure. Seroconversion was observed in 23/42 patients (54.8%). There were no statistically significant differences between the administration of erythromycin or clarithromycin in monotherapy, or in combination with rifampin. Nineteen patients (19.6%) presented acute renal failure and mechanical ventilation was necessary in 22 (22.7%). Twelve patients died (12.5%). Independent prognostic factors associated with death included respiratory rate > 30 breaths/min, urea > 60 mg/dL and PaO2 < 60 mmHg. A significant linear association was found between severity scale scores and the presence of complications or mortality. The Legionella urinary antigen test permits early diagnosis and treatment of this disease. The severity scale is an indicator of complications or death.

  11. Antibacterial activities of gemifloxacin, levofloxacin, gatifloxacin, moxifloxacin and erythromycin against intracellular Legionella pneumophila and Legionella micdadei in human monocytes.

    PubMed

    Baltch, Aldona L; Bopp, Lawrence H; Smith, Raymond P; Michelsen, Phyllis B; Ritz, William J

    2005-07-01

    The antibacterial activity of a new fluoroquinolone, gemifloxacin, was tested against intracellular Legionella pneumophila and Legionella micdadei and was compared with the activities of levofloxacin, gatifloxacin, moxifloxacin and erythromycin. For intracellular assays, bacteria were used to infect human monocyte-derived macrophages prepared from heparinized blood of healthy volunteers. Antibiotics were added following phagocytosis. Numbers of viable bacteria were determined at 0, 24, 48, 72 and 96 h. The intracellular antibacterial activity of gemifloxacin was concentration- and time-dependent. All of the quinolones had similar activities against L. pneumophila and L. micdadei at 10 x MIC, but there were minor differences: at 24 h moxifloxacin was significantly more active than the other quinolones against L. pneumophila, while gemifloxacin was more active against L. micdadei (P < 0.01). All of the quinolones were markedly more active than erythromycin (P < 0.01). The antibacterial effect of gemifloxacin against L. pneumophila following drug removal at 24 h persisted for 72 h at 20 x MIC but not at 10 x MIC, while for L. micdadei the antibacterial effect persisted for 24 h at 10 x MIC. All of the quinolones had similar activities against intracellular L. pneumophila and L. micdadei and were markedly more effective than erythromycin.

  12. Role of rifampin-based combination therapy for severe community-acquired Legionella pneumophila pneumonia.

    PubMed

    Varner, Terra R; Bookstaver, P Brandon; Rudisill, Celeste N; Albrecht, Helmut

    2011-07-01

    To review the literature concerning the role of rifampin in the combination treatment of Legionella pneumophila pneumonia. A search of MEDLINE and Ovid databases was conducted (January 1970-May 2011) using the search terms Legionella pneumophila, pneumonia, Legionnaires' disease, rifampin or rifampicin, macrolide, fluoroquinolone, erythromycin, clarithromycin, levofloxacin, ciprofloxacin, and moxifloxacin In vivo studies published in English that compared antimicrobial therapies including rifampin for the treatment of Legionella pneumonia, as well as in vitro studies including an assessment of rifampin bioactivity, were included. Macrolides and fluoroquinolones have been effective as monotherapy in the treatment of L. pneumophila pneumonia. This review includes evidence summaries from 4 bioactivity evaluations, 6 clinical studies, and 6 reported cases of combination rifampin use. Combined with supporting evidence, the role of combination rifampin therapy is further delineated. Interpretation of the data is limited by the potential for selection bias and lack of consistent comparators. Rifampin therapy should be considered only for patients with severe disease or significant comorbid conditions (eg, uncontrolled diabetes, smoking, or obstructive lung disease) including immunocompromised hosts and those refractory to conventional monotherapy regimens. Caution for significant adverse drug events and drug-drug interactions should be taken with the addition of rifampin.

  13. In vitro synergy testing of macrolide-quinolone combinations against 41 clinical isolates of Legionella.

    PubMed Central

    Martin, S J; Pendland, S L; Chen, C; Schreckenberger, P; Danziger, L H

    1996-01-01

    Combination antimicrobial therapy against Legionella species has not been well studied. Several quinolones have activity against Legionella strains, which prompted this in vitro search for a synergistic combination with the macrolides. By a checkerboard assay, erythromycin, clarithromycin, and azithromycin, each in combination with ciprofloxacin and levofloxacin, were tested for synergy against 46 isolates of Legionella. The agar dilution method was employed using buffered charcoal-yeast extract media. A final inoculum of 10(4) CFU per spot was prepared from 24-h growth of each isolate. Plates were incubated at 35 degrees C for 48 h. Synergy, partial synergy, additive effect, or indifference was observed for all combinations of antibiotics tested. There was no antagonism observed. Synergy occurred to a significantly greater extent for the clarithromycin-levofloxacin (P = 0.0001) and azithromycin-levofloxacin (P = 0.003) combinations versus erythromycin-levofloxacin. The azithromycin-ciprofloxacin combination demonstrated significantly greater synergy than did either erythromycin-ciprofloxacin (P = 0.003) or clarithromycin-ciprofloxacin (P = 0.001). The newer macrolides clarithromycin and azithromycin may be more active in combination with a fluoroquinolone than is erythromycin. PMID:8726012

  14. Metabolism of the vacuolar pathogen Legionella and implications for virulence

    PubMed Central

    Manske, Christian; Hilbi, Hubert

    2014-01-01

    Legionella pneumophila is a ubiquitous environmental bacterium that thrives in fresh water habitats, either as planktonic form or as part of biofilms. The bacteria also grow intracellularly in free-living protozoa as well as in mammalian alveolar macrophages, thus triggering a potentially fatal pneumonia called “Legionnaires' disease.” To establish its intracellular niche termed the “Legionella-containing vacuole” (LCV), L. pneumophila employs a type IV secretion system and translocates ~300 different “effector” proteins into host cells. The pathogen switches between two distinct forms to grow in its extra- or intracellular niches: transmissive bacteria are virulent for phagocytes, and replicative bacteria multiply within their hosts. The switch between these forms is regulated by different metabolic cues that signal conditions favorable for replication or transmission, respectively, causing a tight link between metabolism and virulence of the bacteria. Amino acids represent the prime carbon and energy source of extra- or intracellularly growing L. pneumophila. Yet, the genome sequences of several Legionella spp. as well as transcriptome and proteome data and metabolism studies indicate that the bacteria possess broad catabolic capacities and also utilize carbohydrates such as glucose. Accordingly, L. pneumophila mutant strains lacking catabolic genes show intracellular growth defects, and thus, intracellular metabolism and virulence of the pathogen are intimately connected. In this review we will summarize recent findings on the extra- and intracellular metabolism of L. pneumophila using genetic, biochemical and cellular microbial approaches. Recent progress in this field sheds light on the complex interplay between metabolism, differentiation and virulence of the pathogen. PMID:25250244

  15. Metabolism of the vacuolar pathogen Legionella and implications for virulence.

    PubMed

    Manske, Christian; Hilbi, Hubert

    2014-01-01

    Legionella pneumophila is a ubiquitous environmental bacterium that thrives in fresh water habitats, either as planktonic form or as part of biofilms. The bacteria also grow intracellularly in free-living protozoa as well as in mammalian alveolar macrophages, thus triggering a potentially fatal pneumonia called "Legionnaires' disease." To establish its intracellular niche termed the "Legionella-containing vacuole" (LCV), L. pneumophila employs a type IV secretion system and translocates ~300 different "effector" proteins into host cells. The pathogen switches between two distinct forms to grow in its extra- or intracellular niches: transmissive bacteria are virulent for phagocytes, and replicative bacteria multiply within their hosts. The switch between these forms is regulated by different metabolic cues that signal conditions favorable for replication or transmission, respectively, causing a tight link between metabolism and virulence of the bacteria. Amino acids represent the prime carbon and energy source of extra- or intracellularly growing L. pneumophila. Yet, the genome sequences of several Legionella spp. as well as transcriptome and proteome data and metabolism studies indicate that the bacteria possess broad catabolic capacities and also utilize carbohydrates such as glucose. Accordingly, L. pneumophila mutant strains lacking catabolic genes show intracellular growth defects, and thus, intracellular metabolism and virulence of the pathogen are intimately connected. In this review we will summarize recent findings on the extra- and intracellular metabolism of L. pneumophila using genetic, biochemical and cellular microbial approaches. Recent progress in this field sheds light on the complex interplay between metabolism, differentiation and virulence of the pathogen.

  16. Prevalence and distribution of Legionella spp in potable water systems in Germany, risk factors associated with contamination, and effectiveness of thermal disinfection.

    PubMed

    Kruse, Eva-Brigitta; Wehner, Arno; Wisplinghoff, Hilmar

    2016-04-01

    Worldwide, Legionella spp are a common cause of community-acquired pneumonia. Potable water systems are a main reservoir; however, exposure in the community is unknown. Water samples from 718 buildings in Germany were collected. Possible risk factors were prospectively recorded. All samples were tested for Legionella spp using cultural microbiologic methods. Samples were assigned to 1 of 5 levels of contamination. Statistical analysis was performed to determine the influence of risk factors for contamination and, in a subgroup of buildings, for unsuccessful thermal disinfection. In total, 4,482 water samples from 718 different water supply systems were analyzed. In 233 buildings (32.7%), Legionella spp were identified, 148 (63.5%) of which had a medium or higher level of contamination. The most common species was Legionella pneumophila (94%). Contamination was strongly associated with temperature in the circulation, but not with the size of the building, time of the year, or transport time to the laboratory. Thermal disinfection was successful in fewer than half of the buildings. There is relevant exposure to Legionella spp in the community. Water systems are not always up to current technical standards. Although microbiological risk assessment remains a challenge, there is a case for monitoring for Legionella spp outside of hospitals. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  17. Legionella and Mycobacterium Occurrence/Persistence in Homes and Office Buildings

    EPA Science Inventory

    Legionella and non-tuberculous Mycobacterium species are two of the more important environmental pathogens that cause human health effects. They contribute to the highest economic burden and one of the heaviest disease burdens of all of the waterborne pathogens that pose a risk t...

  18. Isoprenoid quinones of the genus Legionella.

    PubMed Central

    Karr, D E; Bibb, W F; Moss, C W

    1982-01-01

    Representative strains of each of the named species of Legionella were examined for isoprenoid quinones by reverse-phase thin-layer chromatography. All strains contained three or more ubiquinones (Q9, Q10, Q11, Q12, Q13) which were useful for placing the species into one of three distinct groups. Group 1 contained L. longbeachae, L. bozemanii, L. dumoffi, and L. gormanii; group 2 contained only L. micdadei; and group 3 contained only L. pneumophila. The identities of the quinones were established by UV spectroscopy and mass spectrometry. PMID:7107837

  19. Physical and chemical parameter correlations with technical and technological characteristics of heating systems and the presence of Legionella spp. in the hot water supply.

    PubMed

    Rakić, Anita; Štambuk-Giljanović, Nives

    2016-02-01

    The purpose of this study was to evaluate the prevalence of Legionella spp. and compare the quality of hot water between four facilities for accommodation located in Southern Croatia (the Split-Dalmatian County). The research included data collection on the technical and technological characteristics in the period from 2009 to 2012. The survey included a type of construction material for the distribution and internal networks, heating system water heater type, and water consumption. Changes in water quality were monitored by determination of the physical and chemical parameters (temperature, pH, free chlorine residual concentrations, iron, zinc, copper and manganese) in the samples, as well as the presence and concentration of bacteria Legionella spp. The temperature is an important factor for the development of biofilms, and it is in negative correlation with the appearance of Legionella spp. Positive correlations between the Fe and Zn concentrations and Legionella spp. were established, while the inhibitory effect of a higher Cu concentration on the Legionella spp. concentration was proven. Legionella spp. were identified in 38/126 (30.2%) of the water samples from the heating system with zinc-coated pipes, as well as in 78/299 (26.1%) of the samples from systems with plastic pipes. A similar number of Legionella spp. positive samples were established regardless of the type of the water heating system (central or independent). The study confirms the necessity of regular microbial contamination monitoring of the drinking water distribution systems (DWDSs).

  20. Comparison of five methods for extraction of Legionella pneumophila from respiratory specimens.

    PubMed

    Wilson, Deborah; Yen-Lieberman, Belinda; Reischl, Udo; Warshawsky, Ilka; Procop, Gary W

    2004-12-01

    The efficiencies of five commercially available nucleic acid extraction methods were evaluated for the recovery of a standardized inoculum of Legionella pneumophila in respiratory specimens (sputum and bronchoalveolar lavage [BAL] specimens). The concentrations of Legionella DNA recovered from sputa with the automated MagNA Pure (526,200 CFU/ml) and NucliSens (171,800 CFU/ml) extractors were greater than those recovered with the manual methods (i.e., Roche High Pure kit [133,900 CFU/ml], QIAamp DNA Mini kit [46,380 CFU/ml], and ViralXpress kit [13,635 CFU/ml]). The rank order was the same for extracts from BAL specimens, except that for this specimen type the QIAamp DNA Mini kit recovered more than the Roche High Pure kit.

  1. Legionella and risk management in hospitals-A bibliographic research methodology for people responsible for built environment and facility management.

    PubMed

    Leiblein, Thomas W; Tucker, Matthew; Ashall, Mal; Lee, Susanne B; Gollnisch, Carsten; Hofer, Susanne

    2016-11-01

    An ongoing research project investigates the roles and duties of persons responsible for the built environment with respect to risk management of water systems and Legionella prevention from a facility management's perspective. Our literature review provides an approach for selecting and analysing abstracts of initially 177 journal articles, subjected to certain topic-specific inclusion and exclusion criteria. Different decision strategies of either logic 'yes/no', Boolean operators 'OR' or 'AND' and decisions for single counts or cumulative counts of the identified three principal keywords 'Legionella', 'hospital' and 'water', were completed. A final list of ten principal reference articles from 29 journals was compiled. It suggests that the interconnected perspective of water systems, Legionella and hospitals seems to be underrepresented in the field of the built environment and facility management. The term 'stakeholder', which would refer to decision-makers, was not found more than once. Our result is a useful summary of established sources of information on environmental Legionella research. The results can be helpful for those new to the topic. Copyright © 2016 Elsevier GmbH. All rights reserved.

  2. Efficacy of the detection of Legionella in hot and cold water samples by culture and PCR. II. Examination of native samples from various sources.

    PubMed

    Stojek, Nimfa Maria; Wójcik-Fatla, Angelina; Dutkiewicz, Jacek

    2012-01-01

    A total of 123 water samples were examined in parallel by culture and semi-nested PCR for the presence of Legionella. They comprised: 35 samples of hot water distributed by the urban municipal water supply system (MWSS) taken in institutions, 45 samples of hot water distributed by urban MWSS taken in dwellings, 27 samples of cold water distributed by rural MWSS taken in dwellings, and 16 samples of cold well water taken in rural areas. The greatest frequency of the isolation of Legionella by culture (88.6%) was recorded in the samples of hot water from the urban institutions, having been greater compared to all other sources (p<0.001). The frequency of Legionella isolation from hot water in urban dwellings (28.9%) was significantly greater compared to the combined value (2.3%) for cold water from rural MWSS and wells (p<0.001). Strains belonging to Legionella pneumophila serogroups 2-14 predominated in the examined samples, while strains of L. pneumophila serogroup 1 and strains of Legionella spp. (other than L. pneumophila) were 3-fold less numerous. The rates of positive findings in the semi-nested PCR (stage 2) were greater than culture isolations in all kinds of samples, except for urban institutions. The correlation between the culture and PCR results was positive for samples of hot water from urban MWSS (p<0.01), but not for samples of cold water from rural MWSS and wells (p>0.5). A significant correlation was found between rates of PCR-positive results and numbers of Legionella pneumophila serogroups 2-14 strains, but not for other Legionella serogroups or species. In conclusion, our results support the opinion that though PCR cannot be a substitute for the isolation of Legionella by culture, it could be regarded as an useful complementary method.

  3. [Sequence-based typing of enviromental Legionella pneumophila isolates in Guangzhou].

    PubMed

    Zhang, Ying; Qu, Pinghua; Zhang, Jian; Chen, Shouyi

    2011-03-01

    To characterize the genes of Legionella pneumophila isolated from different water source in Guangzhou from 2006 to 2009. To genotype the strains by using sequence-based typing (SBT) scheme. In total 44 L. pneumophila strains were identified by SBT with 7 diversifying genes of flaA, asd, mip, pilE, mompS, proA and neuA. Analysis of the amplicons sequence was taken in the European Working Group for Legionella Infections (EWGLI) international SBT database to obtain the allelic profiles and sequence types (STs). Serogroups were typed by latex agglutination test. Data from SBT revealed a high diversity among the strains and ST01 accounts for 30% (13/ 44). Fifteen new STs were discovered from 20 STs and 2 of them were newly assigned (ST887 and ST888) by EWGLI. SBT Phylogenetic tree was generated by SplitsTree and BURST programs. High diversity and specificity were observed of the L. pneumophila strains in Guangzhou. SBT is useful for L. pneumophila genomic study and epidemiological surveillance.

  4. A hospital outbreak of Legionella from a contaminated water supply.

    PubMed

    Tercelj-Zorman, Marjeta; Seljak, Marija; Stare, Janez; Mencinger, Joze; Rakovec, Joze; Rylander, Ragnar; Strle, Franc

    2004-03-01

    The authors performed a cross-sectional epidemiological survey to investigate the source of a hospital Legionella outbreak originating in contaminated water. Water temperature and air humidity were measured around possible contamination sources. A dead-end pipe was found to contain Legionella pneumophila serogroup 1. All individuals who acquired legionellosis had spent at least 30 min within 2 m of the contamination source. Among staff, 41 of 71 were exposed, and 31 of these fell ill. All 7 patients exposed to the contaminated water acquired legionellosis. None of the 94 bed-ridden patients from the same units developed the disease. An aerosol with 60% relative air humidity was formed near the suspect water faucets, but the humidity fell rapidly farther from the water source, suggesting that desiccation decreased the risk of infection. The healthy personnel and patients closest to the source acquired legionellosis, suggesting that risk was related less to compromised patients than to exposure.

  5. Wernher von Braun

    NASA Image and Video Library

    1954-01-01

    Marshall Center Director Dr. Wernher Von Braun is pictured with Walt Disney during a visit to the Marshall Space Flight Center in 1954. In the 1950s, Dr. Von Braun while working in California on the Saturn project, also worked with Disney studios as a technical director in making three films about Space Exploration for television. Disney's tour of Marshall in 1965 was Von Braun's hope for a renewed public interest in the future of the Space Program at NASA.

  6. Disk diffusion antimicrobial susceptibility testing of members of the family Legionellaceae including erythromycin-resistant variants of Legionella micdadei.

    PubMed Central

    Dowling, J N; McDevitt, D A; Pasculle, A W

    1984-01-01

    Disk diffusion antimicrobial susceptibility testing of members of the family Legionellaceae was accomplished on buffered charcoal yeast extract agar by allowing the bacteria to grow for 6 h before placement of the disks, followed by an additional 42-h incubation period before the inhibitory zones were measured. This system was standardized by comparing the zone sizes with the MICs for 20 antimicrobial agents of nine bacterial strains in five Legionella species and of 19 laboratory-derived, erythromycin-resistant variants of Legionella micdadei. A high, linear correlation between zone size and MIC was found for erythromycin, trimethoprim, penicillin, ampicillin, carbenicillin, cephalothin, cefamandole, cefoxitin, moxalactam, chloramphenicol, vancomycin, and clindamycin. Disk susceptibility testing could be employed to screen Legionella isolates for resistance to any of these antimicrobial agents, of which only erythromycin is known to be efficacious in the treatment of legionellosis. With selected antibiotics, disk susceptibility patterns also appeared to accurately identify to the species level the legionellae. The range of the MICs of the legionellae for rifampin and the aminoglycosides was too small to determine whether the correlation of zone size with MIC was linear. However, laboratory-derived, high-level rifampin-resistant variants of L. micdadei demonstrated no inhibition zone around the rifampin disk, indicating that disk susceptibility testing would likely identify a rifampin-resistant clinical isolate. Of the antimicrobial agents tested, the only agents for which disk susceptibility testing was definitely not possible on buffered charcoal yeast extract agar were oxacillin, the tetracyclines, and the sulfonamides. PMID:6565706

  7. Colonization by Legionella spp. of water networks in residential buildings of the Province of Pisa, Italy.

    PubMed

    Baggiani, A; Casini, B; Totaro, M; Aquino, F; Valentini, P; Bruni, B; Porretta, A; Casalini, F; Miccoli, M; Privitera, G

    2015-01-01

    Despite the increase of community acquired cases of legionellosis in Italy over the last years, the Italian guidelines do not give indications for prevention and control of Legionella in the hot water networks (or centralized conditioning systems) of residential buildings. We performed a survey on eight medium sized apartment buildings in the Pisa district to assess the prevalence of Legionella spp. in the water network and the respondance to drinking water requisites at the point of use, according to the Italian norms. For each building two hot water and three cold water samples (located at water entrance from the aqueduct network into the building pipework, at the exit from pressure autoclave, and at a remote tap) were collected. Legionella was detected in 20% of residential buildings, mostly in those with a central hot water production system. The study highlights a condition of potential risk for susceptible population subgroups and supports the need for measures of risk assessment and control.

  8. The Legionella pneumophila Collagen-Like Protein Mediates Sedimentation, Autoaggregation, and Pathogen-Phagocyte Interactions

    PubMed Central

    Abdel-Nour, Mena; Duncan, Carla; Prashar, Akriti; Rao, Chitong; Ginevra, Christophe; Jarraud, Sophie; Low, Donald E.; Ensminger, Alexander W.; Terebiznik, Mauricio R.

    2014-01-01

    Although only partially understood, multicellular behavior is relatively common in bacterial pathogens. Bacterial aggregates can resist various host defenses and colonize their environment more efficiently than planktonic cells. For the waterborne pathogen Legionella pneumophila, little is known about the roles of autoaggregation or the parameters which allow cell-cell interactions to occur. Here, we determined the endogenous and exogenous factors sufficient to allow autoaggregation to take place in L. pneumophila. We show that isolates from Legionella species which do not produce the Legionella collagen-like protein (Lcl) are deficient in autoaggregation. Targeted deletion of the Lcl-encoding gene (lpg2644) and the addition of Lcl ligands impair the autoaggregation of L. pneumophila. In addition, Lcl-induced autoaggregation requires divalent cations. Escherichia coli producing surface-exposed Lcl is able to autoaggregate and shows increased biofilm production. We also demonstrate that L. pneumophila infection of Acanthamoeba castellanii and Hartmanella vermiformis is potentiated under conditions which promote Lcl dependent autoaggregation. Overall, this study shows that L. pneumophila is capable of autoaggregating in a process that is mediated by Lcl in a divalent-cation-dependent manner. It also reveals that Lcl potentiates the ability of L. pneumophila to come in contact, attach, and infect amoebae. PMID:24334670

  9. Detection limits of Legionella pneumophila in environmental samples after co-culture with Acanthamoeba polyphaga

    PubMed Central

    2013-01-01

    Background The efficiency of recovery and the detection limit of Legionella after co-culture with Acanthamoeba polyphaga are not known and so far no investigations have been carried out to determine the efficiency of the recovery of Legionella spp. by co-culture and compare it with that of conventional culturing methods. This study aimed to assess the detection limits of co-culture compared to culture for Legionella pneumophila in compost and air samples. Compost and air samples were spiked with known concentrations of L. pneumophila. Direct culturing and co-culture with amoebae were used in parallel to isolate L. pneumophila and recovery standard curves for both methods were produced for each sample. Results The co-culture proved to be more sensitive than the reference method, detecting 102-103 L. pneumophila cells in 1 g of spiked compost or 1 m3 of spiked air, as compared to 105-106 cells in 1 g of spiked compost and 1 m3 of spiked air. Conclusions Co-culture with amoebae is a useful, sensitive and reliable technique to enrich L. pneumophila in environmental samples that contain only low amounts of bacterial cells. PMID:23442526

  10. Monitoring of biofilm-associated Legionella pneumophila on different substrata in model cooling tower system.

    PubMed

    Türetgen, Irfan; Cotuk, Aysin

    2007-02-01

    Cooling towers have the potential to develop infectious concentrations of Legionella pneumophila. Legionella counts increases where biofilm and warm water temperatures are present. In this study, biofilm associated L. pneumophila and heterotrophic bacteria were compared in terms of material dependence. Model cooling tower system was experimentally infected by L. pneumophila standard strain and monthly monitored. Different materials were tested for a period of 180 days. The lowest L. pneumophila and heterotrophic plate counts were measured on plastic polymers, whereas L. pneumophila and heterotrophic bacteria were accumulated rapidly on galvanized steel surfaces. It can be concluded that selection of plastic polymers, as a manufacturing material, are suitable for recirculating water systems.

  11. Occurrence of Legionella in hot water systems of single-family residences in suburbs of two German cities with special reference to solar and district heating.

    PubMed

    Mathys, Werner; Stanke, Juliane; Harmuth, Margarita; Junge-Mathys, Elisabeth

    2008-03-01

    A total of 452 samples from hot water systems of randomly selected single family residences in the suburbs of two German cities were analysed for the occurrence of Legionella. Technical data were documented using a standardized questionnaire to evaluate possible factors promoting the growth of the bacterium in these small plumbing systems. All houses were supplied with treated groundwater from public water works. Drinking water quality was within the limits specified in the German regulations for drinking water and the water was not chlorinated. The results showed that plumbing systems in private houses that provided hot water from instantaneous water heaters were free of Legionella compared with a prevalence of 12% in houses with storage tanks and recirculating hot water where maximum counts of Legionella reached 100,000 CFU/100ml. The presence of L. pneumophila accounted for 93.9% of all Legionella positive specimens of which 71.8% belonged to serogroup 1. The volume of the storage tank, interrupting circulation for several hours daily and intermittently raising hot water temperatures to >60 degrees C had no influence on Legionella counts. Plumbing systems with copper pipes were more frequently contaminated than those made of synthetic materials or galvanized steel. An inhibitory effect due to copper was not present. Newly constructed systems (<2 years) were not colonized. The type of hot water preparation had a marked influence. More than 50% of all houses using district heating systems were colonized by Legionella. Their significantly lower hot water temperature is thought to be the key factor leading to intensified growth of Legionella. Although hot water systems using solar energy to supplement conventional hot water supplies operate at temperatures 3 degrees C lower than conventional systems, this technique does not seem to promote proliferation of the bacterium. Our data show convincingly that the temperature of the hot water is probably the most important

  12. Geostatistics - a tool applied to the distribution of Legionella pneumophila in a hospital water system.

    PubMed

    Laganà, Pasqualina; Moscato, Umberto; Poscia, Andrea; La Milia, Daniele Ignazio; Boccia, Stefania; Avventuroso, Emanuela; Delia, Santi

    2015-01-01

    Legionnaires' disease is normally acquired by inhalation of legionellae from a contaminated environmental source. Water systems of large buildings, such as hospitals, are often contaminated with legionellae and therefore represent a potential risk for the hospital population. The aim of this study was to evaluate the potential contamination of Legionella pneumophila (LP) in a large hospital in Italy through georeferential statistical analysis to assess the possible sources of dispersion and, consequently, the risk of exposure for both health care staff and patients. LP serogroups 1 and 2-14 distribution was considered in the wards housed on two consecutive floors of the hospital building. On the basis of information provided by 53 bacteriological analysis, a 'random' grid of points was chosen and spatial geostatistics or FAIk Kriging was applied and compared with the results of classical statistical analysis. Over 50% of the examined samples were positive for Legionella pneumophila. LP 1 was isolated in 69% of samples from the ground floor and in 60% of sample from the first floor; LP 2-14 in 36% of sample from the ground floor and 24% from the first. The iso-estimation maps show clearly the most contaminated pipe and the difference in the diffusion of the different L. pneumophila serogroups. Experimental work has demonstrated that geostatistical methods applied to the microbiological analysis of water matrices allows a better modeling of the phenomenon under study, a greater potential for risk management and a greater choice of methods of prevention and environmental recovery to be put in place with respect to the classical statistical analysis.

  13. Comparison of Legionella longbeachae and Legionella pneumophila cases in Scotland; implications for diagnosis, treatment and public health response.

    PubMed

    Cameron, R L; Pollock, K G J; Lindsay, D S J; Anderson, E

    2016-02-01

    The reported incidence of Legionnaires' disease caused by Legionella longbeachae has increased since 2008 in Scotland. While microbiological and epidemiological studies have identified exposure to growing media as a risk factor for infection, little is known about the differences regarding disease risk factors, clinical features and outcomes of infection with L. longbeachae when compared with L. pneumophila. A nested case-case study was performed comparing 12 L. longbeachae cases with 25 confirmed L. pneumophila cases. Fewer L. longbeachae infected patients reported being smokers [27% (95% CI 2-52%) vs. 68% (95% CI 50-86%), P = 0.034] but more L. longbeachae patients experienced breathlessness [67% (95% CI 40-94%) vs. 28% (95% CI 10-46%), P = 0.036]. Significantly more L. longbeachae-infected patients received treatment in intensive care [50% (95% CI 22-78%) vs. 12% (95% CI 0-25%), P = 0.036]. However, the differences in diagnostic methods between the two groups may have led to only the most severe cases of L. longbeachae being captured by the surveillance system. No differences were observed in any of the other pre-hospital symptoms assessed. Our results highlight the similarity of Legionnaires' disease caused by L. pneumophila and L. longbeachae, and reinforce the importance of diagnostic tools other than the urinary antigen assays for the detection of non-L. pneumophila species. Unfortunately, cases of community-acquired pneumonia caused by Legionella species will continue to be underdiagnosed unless routine testing criteria changes.

  14. Dr. Wernher von Braun

    NASA Technical Reports Server (NTRS)

    2004-01-01

    Dr. von Braun is looking out from a 10th floor window of building 4200 at the Marshall Space Flight Center (MSFC). He was the first Center Director and served as the Director from July 1960 through February 1970. Following World War II, Dr. von Braun and his German colleagues arrived in the United States under the Project Paperclip (American acquisition of German rocket experts) to continue their rocket development work. In 1950, von Braun and his German Rocket Team (also called the Peenemuende Team) were transferred from Ft. Bliss, Texas to Huntsville, Alabama to work for the Army's rocket program at Redstone Arsenal and later, NASA's Marshall Space Flight Center (MSFC). Under Dr. von Braun's leadership, MSFC developed the Saturn V launch vehicle, which placed the first men, two American astronauts, on the Moon. Wernher von Braun's life was dedicated to expanding man's knowledge through the exploration of space.

  15. Necessity and Effect of Combating Legionella pneumophila in Municipal Shower Systems

    PubMed Central

    Wiik, Ragnhild; Krøvel, Anne Vatland

    2014-01-01

    The objective was to obtain research-based, holistic knowledge about necessity and effect of practiced measures against L. pneumophila in municipal shower systems in Stavanger, Norway. The effects of hot water treatment and membrane-filtering were investigated and compared to no intervention at all. The studies were done under real-world conditions. Additionally, a surveillance pilot study of municipal showers in Stavanger was performed. The validity of high total plate count (TPC) as an indication of L. pneumophila was evaluated. A simplified method, named “dripping method”, for detection and quantification of L. pneumophila was developed. The sensitivity of the dripping method is 5 colony-forming units of L. pneumophila/ml. The transference of L. pneumophila from shower water to aerosols was studied. Interviews and observational studies among the stakeholders were done in order to identify patterns of communication and behavior in a Legionella risk perspective. No substantial effects of the measures against L. pneumophila were demonstrated, except for a distally placed membrane filter. No significant positive correlation between TPC and L. pneumophila concentrations were found. L. pneumophila serogroup 2–14 was demonstrated in 21% of the 29 buildings tested in the surveillance pilot. Relatively few cells of L. pneumophila were transferred from shower water to aerosols. Anxiety appeared as the major driving force in the risk governance of Legionella. In conclusion, the risk of acquiring Legionnaires' disease from municipal shower systems is evaluated as low and uncertain. By eliminating ineffective approaches, targeted Legionella risk governance can be practiced. Risk management by surveillance is evaluated as appropriate. PMID:25490721

  16. Legionella species and serogroups in Malaysian water cooling towers: identification by latex agglutination and PCR-DNA sequencing of isolates.

    PubMed

    Yong, Stacey Foong Yee; Goh, Fen-Ning; Ngeow, Yun Fong

    2010-03-01

    In this study, we investigated the distribution of Legionella species in water cooling towers located in different parts of Malaysia to obtain information that may inform public health policies for the prevention of legionellosis. A total of 20 water samples were collected from 11 cooling towers located in three different states in east, west and south Malaysia. The samples were concentrated by filtration and treated with an acid buffer before plating on to BCYE agar. Legionella viable counts in these samples ranged from 100 to 2,000 CFU ml(-1); 28 isolates from the 24 samples were examined by latex agglutination as well as 16S rRNA and rpoB PCR-DNA sequencing. These isolates were identified as Legionella pneumophila serogroup 1 (35.7%), L. pneumophila serogroup 2-14 (39%), L. pneumophila non-groupable (10.7%), L. busanensis, L. gormanii, L. anisa and L. gresilensis. L. pneumophila was clearly the predominant species at all sampling sites. Repeat sampling from the same cooling tower and testing different colonies from the same water sample showed concurrent colonization by different serogroups and different species of Legionella in some of the cooling towers.

  17. Genotypic variability and persistence of Legionella pneumophila PFGE patterns in 34 cooling towers from two different areas.

    PubMed

    Sanchez, Inma; Garcia-Nuñez, Marian; Ragull, Sonia; Sopena, Nieves; Pedro-Botet, Maria Luisa; Estere, Maria; Rey-Joly, Celestino; Sabria, Miquel; Esteve, Maria

    2008-02-01

    Genotypic variability and clonal persistence are important concepts in molecular epidemiology as they facilitate the search for the source of sporadic cases or outbreaks of legionellosis. We studied the genotypic variability and persistence of Legionella pulsed-field gel electrophoresis (PFGE) patterns over time (period > 6 months) in 34 positive cooling towers from two different areas. In area A, radius of 70 km, 52 indistinguishable PFGE patterns were differentiated among the 27 cooling towers. In 13 cooling towers we observed >or= 2 PFGE patterns. Each cooling tower had its own indistinguishable Legionella PFGE pattern which was not shared with any other cooling tower. In area B, radius of 1 km, 10 indistinguishable PFGE patterns were obtained from the seven cooling towers. In four, we observed >or= 2 PFGE patterns. Three of these 10 indistinguishable PFGE patterns were shared by more than one cooling tower. In 27 of 34 cooling towers the same PFGE pattern was recovered after 6 months to up to 5 years of follow-up. The large genotypic diversity of Legionella observed in the cooling towers aids in the investigation of community outbreaks of Legionnaires' disease. However, shared patterns in small areas may confound the epidemiological investigation. The persistence of some PFGE patterns in cooling towers makes the recovery of the Legionella isolate causing the outbreak possible over time.

  18. Formation of a pathogen vacuole according to Legionella pneumophila: how to kill one bird with many stones.

    PubMed

    Finsel, Ivo; Hilbi, Hubert

    2015-07-01

    Legionella species are ubiquitous, waterborne bacteria that thrive in numerous ecological niches. Yet, in contrast to many other environmental bacteria, Legionella spp. are also able to grow intracellularly in predatory protozoa. This feature mainly accounts for the pathogenicity of Legionella pneumophila, which causes the majority of clinical cases of a severe pneumonia termed Legionnaires' disease. The pathomechanism underlying L. pneumophila infection is based on macrophage resistance, which in turn is largely defined by the opportunistic pathogen's resistance towards amoebae. L. pneumophila replicates in macrophages or amoebae in a unique membrane-bound compartment, the Legionella-containing vacuole (LCV). LCV formation requires the bacterial intracellular multiplication/defective for organelle trafficking (Icm/Dot) type IV secretion system and involves a plethora of translocated effector proteins, which subvert pivotal processes in the host cell. Of the ca. 300 different experimentally validated Icm/Dot substrates, about 50 have been studied and attributed a cellular function to date. The versatility and ingenuity of these effectors' mode of actions is striking. In this review, we summarize insight into the cellular functions and biochemical activities of well-characterized L. pneumophila effector proteins and the host pathways they target. Recent studies not only substantially increased our knowledge about pathogen-host interactions, but also shed light on novel biological mechanisms. © 2015 John Wiley & Sons Ltd.

  19. Two Related Occupational Cases of Legionella longbeachae Infection, Quebec, Canada

    PubMed Central

    Lajoie, Élisabeth; Lord, Judith; Lalancette, Cindy; Marchand, Geneviève; Levac, Éric; Lemieux, Marc-André; Hudson, Patricia; Lajoie, Louise

    2016-01-01

    Two patients with no exposure to gardening compost had related Legionella longbeachae infections in Quebec, Canada. Epidemiologic investigation and laboratory results from patient and soil samples identified the patients’ workplace, a metal recycling plant, as the likely source of infection, indicating a need to suspect occupational exposure for L. longbeachae infections. PMID:27314946

  20. [Intra-amoebal development of Legionella pneumophila and the potential role of amoebae in the transmission of Legionnaires' disease].

    PubMed

    Philippe, C; Blech, M F; Hartemann, P

    2006-04-01

    Legionnaires' disease is one of the major infectious risks related to hospital water systems. It is commonly accepted, that the disease is transmitted to man mostly by inhalation of water aerosols contaminated by Legionella pneumophila. The ability of L. pneumophila to multiply intracellularly within some amoebae better explains the ecology, the pathogenicity, and the virulence of this bacterium against human alveolar macrophages. The presence of these amoebae in water systems located where cases of Legionnaire's disease broke out, partly explains the difficulty in eradicating Legionella. Some studies also show that amoebae can play a major role in the transmission of the disease to man. Some other studies point out that inhaled amoebae could be involved in the pathogenesis of Legionnaire's disease. Future strategies to prevent the transmission of Legionella will probably have to include efficient treatments against amoebae.

  1. Acquired factor V inhibitor in a patient receiving venous-venous extracorporeal membrane oxygenation for Legionella pneumonia.

    PubMed

    Leung, Anne K H; Ng, George W Y; Sin, K C; Au, S Y; Lai, K Y; Lee, K L; Law, K I

    2015-04-01

    We report a rare complication of factor V deficiency in a patient having Legionella pneumonia. This patient also had other complications like severe acute respiratory distress syndrome, acute kidney injury, and septic shock that required venous-venous extracorporeal membrane oxygenation support. This is the first reported case of acquired factor V deficiency in a patient receiving extracorporeal membrane oxygenation for Legionella pneumonia. With the combined use of intravenous immunoglobulin, rituximab and plasma exchange, we achieved rapid clearance of the factor V inhibitor within 1 week so as to allow safe decannulation of extracorporeal membrane oxygenation.

  2. Comparison of charcoal- and starch-based media for testing susceptibilities of Legionella species to macrolides, azalides, and fluoroquinolones.

    PubMed Central

    Pendland, S L; Martin, S J; Chen, C; Schreckenberger, P C; Danziger, L H

    1997-01-01

    We compared growth characteristics of 46 Legionella strains grown on buffered charcoal yeast extract alpha (BCYE alpha) agar and buffered starch yeast extract (BSYE) agar and MICs of macrolides, azalides, and fluoroquinolones for these organisms. Growth was poor and not reproducible on BSYE agar. Growth was excellent on BCYE alpha, and MICs were easy to interpret. BCYE alpha is superior to BSYE for testing susceptibilities of Legionella species by agar dilution. PMID:9350781

  3. Wernher von Braun

    NASA Image and Video Library

    1959-01-01

    Five of the seven original astronauts are seen with Dr. von Braun inspecting the Mercury-Redstone hardware in the Fabrication Laboratory of Army Ballistic Missile Agency (ABMA) in 1959. Left to right: Astronauts Walter Schirra, Alan Shepard, John Glenn, Scott Carpenter, Gordon Cooper, and Dr. von Braun.

  4. Detection of Legionella spp. by a nested-PCR assay in air samples of a wastewater treatment plant and downwind distances in Isfahan

    PubMed Central

    Mirzaee, Seyyed Abbas; Nikaeen, Mahnaz; Hajizadeh, Yaghob; Nabavi, BiBi Fatemeh; Hassanzadeh, Akbar

    2015-01-01

    Background: Wastewater contains a variety of pathogens and bio -aerosols generated during the wastewater treatment process, which could be a potential health risk for exposed individuals. This study was carried out to detect Legionella spp. in the bio -aerosols generated from different processes of a wastewater treatment plant (WWTP) in Isfahan, Iran, and the downwind distances. Materials and Methods: A total of 54 air samples were collected and analyzed for the presence of Legionella spp. by a nested- polymerase chain reaction (PCR) assay. A liquid impingement biosampler was used to capture bio -aerosols. The weather conditions were also recorded. Results: Legionella were detected in 6% of the samples, including air samples above the aeration tank (1/9), belt filter press (1/9), and 250 m downwind (1/9). Conclusion: The result of this study revealed the presence of Legionella spp. in air samples of a WWTP and downwind distance, which consequently represent a potential health risk to the exposed individuals. PMID:25802817

  5. Exploring Anti-Bacterial Compounds against Intracellular Legionella

    PubMed Central

    Harrison, Christopher F.; Kicka, Sébastien; Trofimov, Valentin; Berschl, Kathrin; Ouertatani-Sakouhi, Hajer; Ackermann, Nikolaus; Hedberg, Christian; Cosson, Pierre; Soldati, Thierry; Hilbi, Hubert

    2013-01-01

    Legionella pneumophila is a ubiquitous fresh-water bacterium which reproduces within its erstwhile predators, environmental amoeba, by subverting the normal pathway of phagocytosis and degradation. The molecular mechanisms which confer resistance to amoeba are apparently conserved and also allow replication within macrophages. Thus, L. pneumophila can act as an ‘accidental’ human pathogen and cause a severe pneumonia known as Legionnaires’ disease. The intracellular localisation of L. pneumophila protects it from some antibiotics, and this fact must be taken into account to develop new anti-bacterial compounds. In addition, the intracellular lifestyle of L. pneumophila may render the bacteria susceptible to compounds diminishing bacterial virulence and decreasing intracellular survival and replication of this pathogen. The development of a single infection cycle intracellular replication assay using GFP-producing L. pneumophila and Acanthamoeba castellanii amoeba is reported here. This fluorescence-based assay allows for continuous monitoring of intracellular replication rates, revealing the effect of bacterial gene deletions or drug treatment. To examine how perturbations of the host cell affect L. pneumophila replication, several known host-targeting compounds were tested, including modulators of cytoskeletal dynamics, vesicle scission and Ras GTPase localisation. Our results reveal a hitherto unrealized potential antibiotic property of the β-lactone-based Ras depalmitoylation inhibitor palmostatin M, but not the closely related inhibitor palmostatin B. Further characterisation indicated that this compound caused specific growth inhibition of Legionella and Mycobacterium species, suggesting that it may act on a common bacterial target. PMID:24058631

  6. Exploring anti-bacterial compounds against intracellular Legionella.

    PubMed

    Harrison, Christopher F; Kicka, Sébastien; Trofimov, Valentin; Berschl, Kathrin; Ouertatani-Sakouhi, Hajer; Ackermann, Nikolaus; Hedberg, Christian; Cosson, Pierre; Soldati, Thierry; Hilbi, Hubert

    2013-01-01

    Legionella pneumophila is a ubiquitous fresh-water bacterium which reproduces within its erstwhile predators, environmental amoeba, by subverting the normal pathway of phagocytosis and degradation. The molecular mechanisms which confer resistance to amoeba are apparently conserved and also allow replication within macrophages. Thus, L. pneumophila can act as an 'accidental' human pathogen and cause a severe pneumonia known as Legionnaires' disease. The intracellular localisation of L. pneumophila protects it from some antibiotics, and this fact must be taken into account to develop new anti-bacterial compounds. In addition, the intracellular lifestyle of L. pneumophila may render the bacteria susceptible to compounds diminishing bacterial virulence and decreasing intracellular survival and replication of this pathogen. The development of a single infection cycle intracellular replication assay using GFP-producing L. pneumophila and Acanthamoebacastellanii amoeba is reported here. This fluorescence-based assay allows for continuous monitoring of intracellular replication rates, revealing the effect of bacterial gene deletions or drug treatment. To examine how perturbations of the host cell affect L. pneumophila replication, several known host-targeting compounds were tested, including modulators of cytoskeletal dynamics, vesicle scission and Ras GTPase localisation. Our results reveal a hitherto unrealized potential antibiotic property of the β-lactone-based Ras depalmitoylation inhibitor palmostatin M, but not the closely related inhibitor palmostatin B. Further characterisation indicated that this compound caused specific growth inhibition of Legionella and Mycobacterium species, suggesting that it may act on a common bacterial target.

  7. Effectiveness of disinfectants used in cooling towers against Legionella pneumophila.

    PubMed

    García, M T; Pelaz, C

    2008-01-01

    Legionella persists in man-made aquatic installations despite preventive treatments. More information about disinfectants could improve the effectiveness of treatments. This study tests the susceptibility of Legionella pneumophila serogroup (sg) 1 against 8 disinfectants used in cooling tower treatments. We determined the minimal inhibitory concentration (MIC), minimal bactericidal concentration (MBC) and bactericidal effect of sodium hypochlorite (A), hydrogen peroxide with silver nitrate (B), didecyldimethylammonium chloride (C), benzalkonium chloride (D), tributyltetradecylphosphonium chloride (E), tetrahydroxymethylphosphonium sulfide (F), 2,2-dibromonitropropionamide (G) and chloromethylisothiazolone (H) against 28 L. pneumophila sg 1 isolates. MIC and MBC values were equivalent. Bacteria are less susceptible to disinfectants F, B, D and A than to H, E, C and G. All disinfectants induced a bactericidal effect. The effect rate is dose dependent for G, H, F and B; the effect is fast for the rest of disinfectants at any concentration. The bactericidal activity of disinfectants A, G and F depends on the susceptibility test used. All disinfectants have bactericidal activity against L. pneumophila sg 1 at concentrations used in cooling tower treatments. Results depend on the assay for some products.

  8. Acute Legionella pneumophila infection masquerading as acute alcoholic hepatitis.

    PubMed

    Hunter, Jonathan Michael; Chan, Julian; Reid, Angeline Louise; Tan, Chistopher

    2013-01-25

    A middle-aged man had deteriorated rapidly in hospital after being misdiagnosed with acute alcoholic hepatitis. Acute Legionnaires disease (Legionellosis) was subsequently diagnosed on rapid antigen urinary testing and further confirmed serologically. This led to appropriate antibiotic treatment and complete clinical resolution. Physicians caring for patients with alcohol-related liver disease should consider Legionella pneumophila in their differential diagnosis even with a paucity of respiratory symptoms.

  9. Legionella control in the water system of antiquated hospital buildings by shock and continuous hyperchlorination: 5 years experience.

    PubMed

    Orsi, Giovanni Battista; Vitali, Matteo; Marinelli, Lucia; Ciorba, Veronica; Tufi, Daniela; Del Cimmuto, Angela; Ursillo, Paolo; Fabiani, Massimo; De Santis, Susi; Protano, Carmela; Marzuillo, Carolina; De Giusti, Maria

    2014-07-16

    To control the presence of Legionella in an old hospital water system, an integrated strategy of water disinfection-filtration was implemented in the university hospital Umberto I in Rome. Due to antiquated buildings, hospital water system design and hospital extension (38 buildings), shock hyperchlorination (sodium hypochlorite, 20-50 ppm of free chlorine at distal points for 1-2 h) followed by continuous hyperchlorination (0.5-1.0 mg/L at distal points) were adopted, and microbiological and chemical monitoring of the water supply was carried out in the university hospital (December 2006-December 2011). Overall, 1308 samples of cold <20°C (44.5%), mixed ≥20°C ≤ 45°C (37.7%) and hot >45°C (17.8%) water were collected, determining residual free chlorine (0.43 ± 0.44 mg/L), pH (7.43 ± 0.29) and trihalomethanes (8.97 ± 18.56 μg/L). Legionella was isolated in 102 (9.8%) out of 1.041 water samples without filters (L. pneumophila sg 1 17.6%, L. pneumophila sg 2-14 28.4%, L. non pneumophila 53.9%), and in none of the 267 samples with filters. Legionella was recovered in 23 buildings out of 38 and 29 samples (28.4%) exceeded 103 cfu/L. When considering the disinfection treatment Legionella was isolated: before shock hyperchlorination (21.1%), 15 days after shock hyperchlorination (7.8%), 30 days after shock hyperchlorination (3.5%), during continuous hyperchlorination (5.5%) and without continuous hyperchlorination (27.3%). Continuous hyperchlorination following the shock treatment achieved >70% reduction of positive samples, whereas no continuous hyperchlorination after shock treatment was more frequently associated to Legionella isolation (OR 6.41; 95% CI 3.10-13.26; p <0.001). Independent risk factors for Legionella isolation were: residual free chlorine <0.5 mg/L (OR 13.0; 95% CI 1.37 - 123.2; p <0.03), water T° ≥20°C ≤ 45°C (OR 12.0; 95% CI 1.28 - 111.48; p <0.03) and no continuous hyperchlorination after shock treatment (OR 10.3; 95% CI 1.06 - 100

  10. Assessment of Legionella pneumophila in recreational spring water with quantitative PCR (Taqman) assay.

    PubMed

    Shen, Shu-Min; Chou, Ming-Yuan; Hsu, Bing-Mu; Ji, Wen-Tsai; Hsu, Tsui-Kang; Tsai, Hsiu-Feng; Huang, Yu-Li; Chiu, Yi-Chou; Kao, Erl-Shyh; Kao, Po-Min; Fan, Cheng-Wei

    2015-07-01

    Legionella spp. are common in various natural and man-made aquatic environments. Recreational hot spring is frequently reported as an infection hotspot because of various factors such as temperature and humidity. Although polymerase chain reaction (PCR) had been used for detecting Legionella, several inhibitors such as humic substances, calcium, and melanin in the recreational spring water may interfere with the reaction thus resulting in risk underestimation. The purpose of this study was to compare the efficiencies of conventional and Taqman quantitative PCR (qPCR) on detecting Legionella pneumophila in spring facilities and in receiving water. In the results, Taqman PCR had much better efficiency on specifying the pathogen in both river and spring samples. L. pneumophila was detected in all of the 27 river water samples and 45 of the 48 hot spring water samples. The estimated L. pneumophela concentrations ranged between 1.0 × 10(2) and 3.3 × 10(5) cells/l in river water and 72.1-5.7 × 10(6) cells/l in hot spring water. Total coliforms and turbidity were significantly correlated with concentrations of L. pneumophila in positive water samples. Significant difference was also found in water temperature between the presence/absence of L. pneumophila. Our results suggest that conventional PCR may be not enough for detecting L. pneumophila particularly in the aquatic environments full of reaction inhibitors.

  11. Accuracy and precision of Legionella isolation by US laboratories in the ELITE program pilot study.

    PubMed

    Lucas, Claressa E; Taylor, Thomas H; Fields, Barry S

    2011-10-01

    A pilot study for the Environmental Legionella Isolation Techniques Evaluation (ELITE) Program, a proficiency testing scheme for US laboratories that culture Legionella from environmental samples, was conducted September 1, 2008 through March 31, 2009. Participants (n=20) processed panels consisting of six sample types: pure and mixed positive, pure and mixed negative, pure and mixed variable. The majority (93%) of all samples (n=286) were correctly characterized, with 88.5% of samples positive for Legionella and 100% of negative samples identified correctly. Variable samples were incorrectly identified as negative in 36.9% of reports. For all samples reported positive (n=128), participants underestimated the cfu/ml by a mean of 1.25 logs with standard deviation of 0.78 logs, standard error of 0.07 logs, and a range of 3.57 logs compared to the CDC re-test value. Centering results around the interlaboratory mean yielded a standard deviation of 0.65 logs, standard error of 0.06 logs, and a range of 3.22 logs. Sampling protocol, treatment regimen, culture procedure, and laboratory experience did not significantly affect the accuracy or precision of reported concentrations. Qualitative and quantitative results from the ELITE pilot study were similar to reports from a corresponding proficiency testing scheme available in the European Union, indicating these results are probably valid for most environmental laboratories worldwide. The large enumeration error observed suggests that the need for remediation of a water system should not be determined solely by the concentration of Legionella observed in a sample since that value is likely to underestimate the true level of contamination. Published by Elsevier Ltd.

  12. Identification of legionella effectors using bioinformatic approaches.

    PubMed

    Segal, Gil

    2013-01-01

    Legionella pneumophila the causative agent of Legionnaires' disease, actively manipulates host cell processes to establish a replication niche inside host cells. The establishment of its replication niche requires a functional Icm/Dot type IV secretion system which translocates about 300 effector proteins into host cells during infection. Many of these effectors were first identified as effector candidates by several bioinformatic approaches, and these predicted effectors were later examined experimentally for translocation and a large number of which were validated as effector proteins. Here, I summarized the bioinformatic approaches that were used to identify these effectors.

  13. [The journey of Legionella pneumophila from amoebae to macrophage. Reflections on the largest outbreak of legionnaire's disease].

    PubMed

    Segovia Hernández, Manuel

    2005-01-01

    Legionella, the causative agent of legionnaire's disease (LD), can survive and grow in amoebic cells. Free-living amoebae may play a role in the selection of virulence traits and in adaptation to survival in macrophages, and represent an important reservoir of Legionella. These amoebae may act as a Trojan horse bringing hidden bacteria within the human environments. The community outbreak of LD that occurred in Murcia in July 2001, the largest such outbreak ever reported, afforded an unusual opportunity to improve the knowledge of this disease.

  14. Discriminatory genomic fingerprinting of Legionella pneumophila by pulsed-field electrophoresis.

    PubMed Central

    Johnson, W M; Bernard, K; Marrie, T J; Tyler, S D

    1994-01-01

    Eight strains of Legionella pneumophila were used to optimize cleavage of DNA with BssHII, SalI, or SpeI and separation by pulsed-field electrophoresis. Isolates from a community outbreak involving a contaminated hot tub were genomically identical. Cleavage patterns were distinctly different for unrelated environmental and nosocomial strains from a single hospital. Images PMID:7814513

  15. Assessment of antibiotic susceptibility of Legionella pneumophila isolated from water systems in Poland.

    PubMed

    Sikora, Agnieszka; Gładysz, Iwona; Kozioł-Montewka, Maria; Wójtowicz-Bobin, Małgorzata; Stańczak, Tomasz; Matuszewska, Renata; Krogulska, Bożena

    2017-03-21

    Several studies have reported therapy failures in patients with legionnaires'disease; however, antimicrobial resistance of clinical and environmental isolates of Legionella spp. has not yet been documented. Routine susceptibility testing of Legionella spp. is not recommended because of difficulties in determining standard minimal inhibitory concentration values. The purpose of this study was to analyze the antimicrobial susceptibility of Legionella pneumophila. strains isolated from a water supply system. Twenty-eight isolates of L. pneumophila (16 - L. pneumophila SG 1, 12 - L. pneumophila SG 2-14) obtained from water systems in public buildings in Poland were tested. Susceptibility testing was performed using the E-test method. The tested antibiotic were azithromycin, ciprofloxacin, and rifampicin. The medium used for the susceptibility testing was BCYE-, a special medium for Legionella cultivation. Among the tested strains, L. pneumophila was the only one resistant to azithromycin. It was a strain of L. pneumophila SG 2-14 isolated from the water system in a sanitorium. All isolates were found to be sensitive to ciprofloxacin and rifampicin. However, the azithromycin-resistant strain exhibited higher ciprofloxacin and rifampicin MIC (1.5 μg/ml, and 0.19 μg/ml, respectively). The MIC50 for azithromycin, ciprofloxacin, and rifampicin were 0,032, 0,125, and 0,003 μg/ml, respectively. The MIC90 for azithromycin, ciprofloxacin, and rifampicin were 0,032, 0,125, and 0,003 μg/ml, respectively. Azithromycin resistance was found in one strain of L. pneumophila SG 2-14, but the resistance mechanism is unknown and needs further study. It is possible that therapeutic failures in Legionnaires' disease may be associated with bacterial resistance which should be taken into account. The antibiotic sensitivity testing described in this study could be helpful in detecting the resistance of clinical L. pneumophila isolates. Ciprofloxacin and rifampicin have good in vitro

  16. [Legionella pneumophila pneumonia community epidemic outbreak in Barcelona: "The Barceloneta outbreak". Effect on the early diagnosis and treatment].

    PubMed

    Jericó Alba, C; Nogués Solán, X; Santos Martínez, M J; Félez Flor, M; Garcés Jarque, J M; Mariñosa Marré, M; Sanz Salvador, X

    2004-02-01

    Clinical and microbiological descriptive analysis of the outbreak of community legionnaire's disease recorded in the Barcelona's Barcelonesa neighborhood in November 2000. Retrospective review of the epidemiological and clinical manifestations, as well as the evolution of the cases of Legionella pneumophila pneumonia associated with the outbreak and cared of in the Hospital del Mar. The 48 patients evaluated, all of them with confirmed diagnoses, represent 89% of the cases communicated. Seventy-five percent of patients showed some underlying disease, 54% had some criterion for severity, and mortality was 4%. In 81% of cases the detection of the antigen of Legionella pneumophila in urine was the diagnostic method. The detection in urine of the Legionella pneumophila antigen makes possible the early diagnosis of legionnaire's disease, particularly in epidemic outbreaks, which that facilitates the fast establishment of the adequate treatment and contributes to the reduction in mortality even in patients of high risk.

  17. Faster Legionella testing on horizon.

    PubMed

    Pearson, Susan

    2011-08-01

    While the "traditional" way to measure Legionella quantitatively in water is based on a complex culture method where results can take up to 14 days, the last few years have seen the availability of very rapid real-time monitoring of the bacterium in water systems, with the development of quantitative polymerase chain reaction (qPCR), a process which gives results "within hours". To date, however, a lack of consensus on how to interpret such results in relation to those from culture has been a stumbling block, although, as Susan Pearson, a freelance journalist and public relations consultant specialising in medicine and the environment, reports, the positive results of a recent multi-centre European study mean this could soon all change.

  18. Plan for the control of Legionella infections in long-term care facilities: role of environmental monitoring.

    PubMed

    Cristino, Sandra; Legnani, Pier Paolo; Leoni, Erica

    2012-04-01

    In accordance with the international and national guidelines, the Emilia-Romagna Region (Italy) has established regional guidelines for the surveillance and prevention of legionellosis based on the concept of risk assessment, with particular attention to environmental monitoring. The aim of this study was to verify how environmental surveillance in the context of risk assessment plans could help to guide decisions about preventive strategies against Legionella infections in Long Term Care Facilities (LTCF). In six LTCFs in the city of Bologna (Emilia-Romagna Region) a self-control plan was implemented that included the environmental monitoring of Legionella spp. and the surveillance of hospital-acquired Legionnaires' Disease. At baseline, four hot water systems were colonized by Legionella pneumophila (3 LCTFs) and Legionella londiniensis (1 LCTF). In each establishment specific control measures were adopted based on the characteristics of the system, the virulence of the strain and the level of the contamination. The monitoring, carried out for around two years, was also extended to the ways in which the system and the distal water distribution points were used and maintained with respect to the good practices in operation and management. The adopted actions (shock and/or continuous disinfection treatments) and the implementation of the good practice measures reduced the contamination to acceptable and stable levels. No cases of hospital-acquired legionellosis occurred during the period of study. The environmental surveillance was successful in evaluating the risk and identifying the most suitable preventive strategies. Copyright © 2011 Elsevier GmbH. All rights reserved.

  19. Tracking Legionella in air generated from a biological treatment plant: a case study of the outbreak of legionellosis in Norway

    NASA Astrophysics Data System (ADS)

    Blatny, Janet M.; Olsen, Jaran S.; Andreassen, Øyvind; Waagen, Viggo; Reif, Bjørn Anders P.

    2011-05-01

    Two outbreaks of legionellosis occurred in the Sarpsborg/Fredrikstad region southeast of Norway in 2005 and 2008 where more than 60 exposed individuals were infected and 10 case patients died. The air scrubber at Borregaard, a wood-based chemical factory, was identified as the outbreak source. High concentration levels of Legionella species, including the etiological agent L. pneumophila SG1 was found in the aeration ponds, which belongs to Borregaard's biological treatment plant. Results showed that these ponds were able to generate Legionella-containing aerosols that were transported by the wind as such aerosols were measured up to 200 meters downwind of the pond. Our studies did not detect L. pneumophila SG1 isolates, only L. pneumophila SG4 during the air sampling measurement campaign. Furthermore, the operational conditions of the air scrubber proved to be harsh for Legionella growth as the outbreak L. pneumophila strains were not able to grow at 45ºC and pH8 (conditions during the outbreaks). These results, together, lead us to suggest that the aeration pond should be regarded as the primary amplifier and disseminator of Legionella and L. pneumophila and thereby most likely being the outbreak source.

  20. Development of a genus-specific next generation sequencing approach for sensitive and quantitative determination of the Legionella microbiome in freshwater systems.

    PubMed

    Pereira, Rui P A; Peplies, Jörg; Brettar, Ingrid; Höfle, Manfred G

    2017-03-31

    Next Generation Sequencing (NGS) has revolutionized the analysis of natural and man-made microbial communities by using universal primers for bacteria in a PCR based approach targeting the 16S rRNA gene. In our study we narrowed primer specificity to a single, monophyletic genus because for many questions in microbiology only a specific part of the whole microbiome is of interest. We have chosen the genus Legionella, comprising more than 20 pathogenic species, due to its high relevance for water-based respiratory infections. A new NGS-based approach was designed by sequencing 16S rRNA gene amplicons specific for the genus Legionella using the Illumina MiSeq technology. This approach was validated and applied to a set of representative freshwater samples. Our results revealed that the generated libraries presented a low average raw error rate per base (<0.5%); and substantiated the use of high-fidelity enzymes, such as KAPA HiFi, for increased sequence accuracy and quality. The approach also showed high in situ specificity (>95%) and very good repeatability. Only in samples in which the gammabacterial clade SAR86 was present more than 1% non-Legionella sequences were observed. Next-generation sequencing read counts did not reveal considerable amplification/sequencing biases and showed a sensitive as well as precise quantification of L. pneumophila along a dilution range using a spiked-in, certified genome standard. The genome standard and a mock community consisting of six different Legionella species demonstrated that the developed NGS approach was quantitative and specific at the level of individual species, including L. pneumophila. The sensitivity of our genus-specific approach was at least one order of magnitude higher compared to the universal NGS approach. Comparison of quantification by real-time PCR showed consistency with the NGS data. Overall, our NGS approach can determine the quantitative abundances of Legionella species, i. e. the complete Legionella

  1. Virulence Phenotypes of Legionella pneumophila Associated with Noncoding RNA lpr0035

    PubMed Central

    Jayakumar, Deepak; Early, Julie V.

    2012-01-01

    The Philadelphia-1 strain of Legionella pneumophila, the causative organism of Legionnaires' disease, contains a recently discovered noncoding RNA, lpr0035. lpr0035 straddles the 5′ chromosomal junction of a 45-kbp mobile genetic element, pLP45, which can exist as an episome or integrated in the bacterial chromosome. A 121-bp deletion was introduced in strain JR32, a Philadelphia-1 derivative. The deletion inactivated lpr0035, removed the 49-bp direct repeat at the 5′ junction of pLP45, and locked pLP45 in the chromosome. Intracellular multiplication of the deletion mutant was decreased by nearly 3 orders of magnitude in Acanthamoeba castellanii amoebae and nearly 2 orders of magnitude in J774 mouse macrophages. Entry of the deletion mutant into amoebae and macrophages was decreased by >70%. The level of entry in both hosts was restored to that in strain JR32 by plasmid copies of two open reading frames immediately downstream of the 5′ junction and plasmid lpr0035 driven by its endogenous promoter. When induced from a tac promoter, plasmid lpr0035 completely reversed the intracellular multiplication defect in macrophages but was without effect in amoebae. These data are the first evidence of a role for noncoding RNA lpr0035, which has homologs in six other Legionella genomes, in entry of L. pneumophila into amoebae and macrophages and in host-specific intracellular multiplication. The data also demonstrate that deletion of a direct-repeat sequence restricts the mobility of pLP45 and is a means of studying the role of pLP45 mobility in Legionella virulence phenotypes. PMID:22966048

  2. Controlling Legionella and Pseudomonas aeruginosa re-growth in therapeutic spas: implementation of physical disinfection treatments, including UV/ultrafiltration, in a respiratory hydrotherapy system.

    PubMed

    Leoni, E; Sanna, T; Zanetti, F; Dallolio, L

    2015-12-01

    The study aimed to assess the efficacy of an integrated water safety plan (WSP) in controlling Legionella re-growth in a respiratory hydrotherapy system located in a spa centre, supplied with sulphurous water, which was initially colonized by Legionella pneumophila. Heterotrophic plate counts, Pseudomonas aeruginosa, Legionella spp. were detected in water samples taken 6-monthly from the hydrotherapy equipment (main circuit, entry to benches, final outlets). On the basis of the results obtained by the continuous monitoring and the changes in conditions, the original WSP, including physical treatments of water and waterlines, environmental surveillance and microbiological monitoring, was integrated introducing a UV/ultrafiltration system. The integrated treatment applied to the sulphurous water (microfiltration/UV irradiation/ultrafiltration), waterlines (superheated stream) and distal outlets (descaling/disinfection of nebulizers and nasal irrigators), ensured the removal of Legionella spp. and P. aeruginosa and a satisfactory microbiological quality over time. The environmental surveillance was successful in evaluating the hazard and identifying the most suitable preventive strategies to avoid Legionella re-growth. Ultrafiltration is a technology to take into account in the control of microbial contamination of therapeutic spas, since it does not modify the chemical composition of the water, thus allowing it to retain its therapeutic properties.

  3. Legionella longbeachae detected in an industrial cooling tower linked to a legionellosis outbreak, New Zealand, 2015; possible waterborne transmission?

    PubMed

    Thornley, C N; Harte, D J; Weir, R P; Allen, L J; Knightbridge, K J; Wood, P R T

    2017-08-01

    A legionellosis outbreak at an industrial site was investigated to identify and control the source. Cases were identified from disease notifications, workplace illness records, and from clinicians. Cases were interviewed for symptoms and risk factors and tested for legionellosis. Implicated environmental sources were sampled and tested for legionella. We identified six cases with Legionnaires' disease and seven with Pontiac fever; all had been exposed to aerosols from the cooling towers on the site. Nine cases had evidence of infection with either Legionella pneumophila serogroup (sg) 1 or Legionella longbeachae sg1; these organisms were also isolated from the cooling towers. There was 100% DNA sequence homology between cooling tower and clinical isolates of L. pneumophila sg1 using sequence-based typing analysis; no clinical L. longbeachae isolates were available to compare with environmental isolates. Routine monitoring of the towers prior to the outbreak failed to detect any legionella. Data from this outbreak indicate that L. pneumophila sg1 transmission occurred from the cooling towers; in addition, L. longbeachae transmission was suggested but remains unproven. L. longbeachae detection in cooling towers has not been previously reported in association with legionellosis outbreaks. Waterborne transmission should not be discounted in investigations for the source of L. longbeachae infection.

  4. Longitudinal evaluation of the efficacy of heat treatment procedures against Legionella spp. in hospital water systems by using a flow cytometric assay.

    PubMed

    Allegra, Severine; Grattard, Florence; Girardot, Françoise; Riffard, Serge; Pozzetto, Bruno; Berthelot, Philippe

    2011-02-01

    Legionella spp. are frequently isolated in hospital water systems. Heat shock (30 min at 70°C) is recommended by the World Health Organization to control its multiplication. The aim of the study was to evaluate retrospectively the efficacy of heat treatments by using a flow cytometry assay (FCA) able to identify viable but nonculturable (VBNC) cells. The study included Legionella strains (L. pneumophila [3 clusters] and L. anisa [1 cluster]) isolated from four hot water circuits of different hospital buildings in Saint-Etienne, France, during a 20-year prospective surveillance. The strains recovered from the different circuits were not epidemiologically related, but the strains isolated within a same circuit over time exhibited an identical genotypic profile. After an in vitro treatment of 30 min at 70°C, the mean percentage of viable cells and VBNC cells varied from 4.6% to 71.7%. The in vitro differences in heat sensitivity were in agreement with the observed efficacy of preventive and corrective heating measures used to control water contamination. These results suggest that Legionella strains can become heat resistant after heating treatments for a long time and that flow cytometry could be helpful to check the efficacy of heat treatments on Legionella spp. and to optimize the decontamination processes applied to water systems for the control of Legionella proliferation.

  5. Relapsing Legionella pneumophila cellulitis: a case report and review of the literature.

    PubMed

    Han, Jennifer H; Nguyen, Josephine C; Harada, Shuko; Baddour, Larry M; Edelstein, Paul H

    2010-12-01

    Legionella spp. rarely cause soft tissue infections, with only a few cases reported and usually in the setting of immunocompromise. We report a case of L. pneumophila cellulitis, without pneumonia, in a 65-year-old immunocompromised woman. The patient had a history of interstitial lung disease and idiopathic thrombocytopenic purpura, for which she was receiving high-dose corticosteroids, and had recently experienced an episode of L. pneumophila cellulitis of the lower extremity, which responded to an extended course of levofloxacin. She was initially transferred to this institution for definitive workup of presumed B cell lymphoma and, during her hospital course, suffered a relapse of L. pneumophila-associated cellulitis that responded promptly to azithromycin. More unusual organisms such as Legionella spp. should be considered in the etiology of cellulitis, particularly in the setting of immunocompromise, in cases that are refractory to conventional antibiotics routinely administered for skin and soft tissue infections.

  6. Organizing pneumonia pattern in the follow-up CT of Legionella-infected patients.

    PubMed

    Haroon, Attiya; Higa, Futoshi; Hibiya, Kenji; Haranaga, Shusaku; Yara, Satomi; Tateyama, Masao; Fujita, Jiro

    2011-08-01

    The main aim of this study was to describe the appearance of the CT pattern of organizing pneumonia in Legionella-infected patients. Serial CT scans obtained from five sporadic cases of Legionella pneumophila pneumonia were retrospectively reviewed. The mean time of follow-up was 14 days. Chest CT was analyzed with regard to frequency and appearance of CT patterns of pulmonary abnormalities. Consolidation and ground-glass opacities, with or without an air bronchogram, were the most common abnormalities detected in CT scans during follow-up patients with L. pneumophila pneumonia. Two patterns were observed: subpleural and peribronchovascular. The subpleural pattern was seen in four patients and the peribronchovascular pattern in one. Interlobular septal thickening was seen in one patient. Pleural effusion was seen in one patient. The CT pattern of organizing pneumonia, a subpleural pattern, was frequently observed after treatment of L. pneumophila pneumonia.

  7. Atypical Pneumonia: Updates on Legionella, Chlamydophila, and Mycoplasma Pneumonia.

    PubMed

    Sharma, Lokesh; Losier, Ashley; Tolbert, Thomas; Dela Cruz, Charles S; Marion, Chad R

    2017-03-01

    Community-acquired pneumonia (CAP) has multiple causes and is associated with illness that requires admission to the hospital and mortality. The causes of atypical CAP include Legionella species, Chlamydophila, and Mycoplasma. Atypical CAP remains a diagnostic challenge and, therefore, likely is undertreated. This article reviews the advancements in the evaluation and treatment of patients and discusses current conflicts and controversies of atypical CAP. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Acute Legionella pneumophila infection masquerading as acute alcoholic hepatitis

    PubMed Central

    Hunter, Jonathan Michael; Chan, Julian; Reid, Angeline Louise; Tan, Chistopher

    2013-01-01

    A middle-aged man had deteriorated rapidly in hospital after being misdiagnosed with acute alcoholic hepatitis. Acute Legionnaires disease (Legionellosis) was subsequently diagnosed on rapid antigen urinary testing and further confirmed serologically. This led to appropriate antibiotic treatment and complete clinical resolution. Physicians caring for patients with alcohol-related liver disease should consider Legionella pneumophila in their differential diagnosis even with a paucity of respiratory symptoms. PMID:23355576

  9. Effect of amino acid substitution in the staphylococcal peptides warnericin RK and PSMα on their anti-Legionella and hemolytic activities.

    PubMed

    Marchand, Adrienne; Augenstreich, Jacques; Loiseau, Clémence; Verdon, Julien; Lecomte, Sophie; Berjeaud, Jean-Marc

    2015-07-01

    Warnericin RK from Staphylococcus warneri and PSMα from Staphylococcus epidermidis are anti-Legionella peptides which were differently classified in a previous study according to their mode of action. Indeed, warnericin RK is highly hemolytic with a bactericidal mode of action, whereas PSMα is poorly hemolytic with a bacteriostatic mode of action toward L. pneumophila. In order to find anti-Legionella peptides which are not hemolytic, a collection of peptides varying in sequence from warnericin RK to PSMα were designed and synthesized, and their anti-Legionella activities, in terms of growth inhibition, permeabilization, and bactericidal effect, as well as their hemolytic activities, were measured and compared. The results showed that some residues, at position 14 for both peptides for instance, were of major importance for bactericidal and hemolytic activities.

  10. Effect of quinolones and other antimicrobial agents on cell-associated Legionella pneumophila.

    PubMed Central

    Havlichek, D; Saravolatz, L; Pohlod, D

    1987-01-01

    We evaluated the in vitro susceptibility of Legionella pneumophila ATCC 33152 (serogroup I) to 13 antibiotics alone and in combination with rifampin (0.1 mg/liter) by three methods. Extracellular susceptibility was determined by MIC determinations and time kill curves in buffered yeast extract broth, while intracellular susceptibility was determined by peripheral human monocytes in RPMI 1640 culture medium. Antibiotic concentrations equal to or greater than the broth dilution MIC inhibited or killed L. pneumophila by the time kill method, except this was not the case for trimethoprim-sulfamethoxazole. Antibiotic concentrations below the broth dilution MIC did not inhibit Legionella growth. The only antibiotic-rifampin combinations which produced improved killing of L. pneumophila by the time kill method were those in which the logarithmic growth of L. pneumophila occurred during the experiment (rosoxacin, amifloxacin, cinoxacin, trimethoprim-sulfamethoxazole, clindamycin, and doxycycline). Neither direct MICs nor time kill curve assays accurately predicted intracellular L. pneumophila susceptibility. Rifampin, erythromycin, ciprofloxacin, rosoxacin, enoxacin, amifloxacin, gentamicin, clindamycin, and doxycycline all inhibited intracellular L. pneumophila growth at readily achievable concentrations in serum. Cefoxitin and thienamycin showed no inhibition of growth, although they were present extracellularly at concentrations that were 20 to 1,000 times their broth dilution MICs. Clindamycin was the only antibiotic that was able to inhibit intracellular L. pneumophila growth at an extracellular concentration below its MIC. The gentamicin (5 mg/liter)-rifampin combination was the only antibiotic-rifampin combination which demonstrated decreased cell-associated Legionella survival in this model of in vitro susceptibility. PMID:3435101

  11. Extensive recombination events and horizontal gene transfer shaped the Legionella pneumophila genomes

    PubMed Central

    2011-01-01

    Background Legionella pneumophila is an intracellular pathogen of environmental protozoa. When humans inhale contaminated aerosols this bacterium may cause a severe pneumonia called Legionnaires' disease. Despite the abundance of dozens of Legionella species in aquatic reservoirs, the vast majority of human disease is caused by a single serogroup (Sg) of a single species, namely L. pneumophila Sg1. To get further insights into genome dynamics and evolution of Sg1 strains, we sequenced strains Lorraine and HL 0604 1035 (Sg1) and compared them to the available sequences of Sg1 strains Paris, Lens, Corby and Philadelphia, resulting in a comprehensive multigenome analysis. Results We show that L. pneumophila Sg1 has a highly conserved and syntenic core genome that comprises the many eukaryotic like proteins and a conserved repertoire of over 200 Dot/Icm type IV secreted substrates. However, recombination events and horizontal gene transfer are frequent. In particular the analyses of the distribution of nucleotide polymorphisms suggests that large chromosomal fragments of over 200 kbs are exchanged between L. pneumophila strains and contribute to the genome dynamics in the natural population. The many secretion systems present might be implicated in exchange of these fragments by conjugal transfer. Plasmids also play a role in genome diversification and are exchanged among strains and circulate between different Legionella species. Conclusion Horizontal gene transfer among bacteria and from eukaryotes to L. pneumophila as well as recombination between strains allows different clones to evolve into predominant disease clones and others to replace them subsequently within relatively short periods of time. PMID:22044686

  12. Legionella pneumophila serogroup 3 infection: importance of serology.

    PubMed

    Khanna, N; Meikle, A; Gillespie, L; Edwards, G; Lindsay, D

    2012-08-01

    We present a case of Legionella pneumophila serogroup 3 (LP3) infection in a patient with severe community-acquired pneumonia (CAP). The diagnosis was complicated by an initial equivocal L. pneumophila urinary antigen test, followed by two negative samples. LP3 was cultured from a sputum sample and the diagnosis was confirmed by serology 15 days into the admission. This case highlights the importance of considering non-LP1 serogroups as causes of CAP and the role of serological testing in diagnosis.

  13. Fatal coinfection with Legionella pneumophila serogroup 8 and Aspergillus fumigatus.

    PubMed

    Guillouzouic, Aurélie; Bemer, Pascale; Gay-Andrieu, Françoise; Bretonnière, Cédric; Lepelletier, Didier; Mahé, Pierre-Joachim; Villers, Daniel; Jarraud, Sophie; Reynaud, Alain; Corvec, Stéphane

    2008-02-01

    Legionella pneumophila is an important cause of community-acquired and nosocomial pneumonia. We report on a patient who simultaneously developed L. pneumophila serogroup 8 pneumonia and Aspergillus fumigatus lung abscesses. Despite appropriate treatments, Aspergillus disease progressed with metastasis. Coinfections caused by L. pneumophila and A. fumigatus remain exceptional. In apparently immunocompetent patients, corticosteroid therapy is a key risk factor for aspergillosis.

  14. Legionella control in the water system of antiquated hospital buildings by shock and continuous hyperchlorination: 5 years experience

    PubMed Central

    2014-01-01

    Background To control the presence of Legionella in an old hospital water system, an integrated strategy of water disinfection-filtration was implemented in the university hospital Umberto I in Rome. Methods Due to antiquated buildings, hospital water system design and hospital extension (38 buildings), shock hyperchlorination (sodium hypochlorite, 20–50 ppm of free chlorine at distal points for 1–2 h) followed by continuous hyperchlorination (0.5-1.0 mg/L at distal points) were adopted, and microbiological and chemical monitoring of the water supply was carried out in the university hospital (December 2006-December 2011). Results Overall, 1308 samples of cold <20°C (44.5%), mixed ≥20°C ≤ 45°C (37.7%) and hot >45°C (17.8%) water were collected, determining residual free chlorine (0.43 ± 0.44 mg/L), pH (7.43 ± 0.29) and trihalomethanes (8.97 ± 18.56 μg/L). Legionella was isolated in 102 (9.8%) out of 1.041 water samples without filters (L. pneumophila sg 1 17.6%, L. pneumophila sg 2–14 28.4%, L. non pneumophila 53.9%), and in none of the 267 samples with filters. Legionella was recovered in 23 buildings out of 38 and 29 samples (28.4%) exceeded 103 cfu/L. When considering the disinfection treatment Legionella was isolated: before shock hyperchlorination (21.1%), 15 days after shock hyperchlorination (7.8%), 30 days after shock hyperchlorination (3.5%), during continuous hyperchlorination (5.5%) and without continuous hyperchlorination (27.3%). Continuous hyperchlorination following the shock treatment achieved >70% reduction of positive samples, whereas no continuous hyperchlorination after shock treatment was more frequently associated to Legionella isolation (OR 6.41; 95% CI 3.10–13.26; p <0.001). Independent risk factors for Legionella isolation were: residual free chlorine <0.5 mg/L (OR 13.0; 95% CI 1.37 – 123.2; p <0.03), water T° ≥20°C ≤ 45°C (OR 12.0; 95% CI 1.28 – 111.48; p <0.03) and no continuous hyperchlorination after shock

  15. The association of antibiotic treatment regimen and hospital mortality in patients hospitalized with Legionella pneumonia.

    PubMed

    Gershengorn, Hayley B; Keene, Adam; Dzierba, Amy L; Wunsch, Hannah

    2015-06-01

    Guidelines recommend azithromycin or a quinolone antibiotic for treatment of Legionella pneumonia. No clinical study has compared these strategies. We performed a retrospective cohort analysis of adults hospitalized in the United States with a diagnosis of Legionella pneumonia in the Premier Perspectives database (1 July 2008-30 June 2013). Our primary outcome was hospital mortality; we additionally evaluated hospital length of stay, development of Clostridium difficile colitis, and total hospital cost. We used propensity-based matching to compare patients treated with azithromycin vs a quinolone. All analyses were repeated on a subgroup of more severely ill patients, defined as requiring intensive care unit admission or mechanical ventilation or having a predicted probability of hospital mortality in the top quartile for all patients. Legionella pneumonia was diagnosed in 3152 adults across 437 hospitals. Quinolones alone were used in 28.8%, azithromycin alone was used in 34.0%, and 1.8% received both. Crude hospital mortality was similar: 6.6% (95% confidence interval [CI], 5.0%-8.2%) for quinolones vs 6.4% (95% CI, 5.0%-7.9%) for azithromycin (P = .87); after propensity matching (n = 813 in each group), mortality remained similar (6.3% [95% CI, 4.6%-7.9%] vs 6.5% [95% CI, 4.8%-8.2%], P = .84 for the whole cohort, and 14.9% [95% CI, 10.0%-19.8%] vs 18.3% [95% CI, 13.0%-23.6%], P = .36 for the more severely ill). There was no difference in hospital length of stay, development of C. difficile, or total hospital cost. Use of azithromycin alone or a quinolone alone for treatment of Legionella pneumonia was associated with similar hospital mortality. Few patients receive combination therapy. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  16. Legionella pneumophila Seropositivity-Associated Factors in Latvian Blood Donors

    PubMed Central

    Valciņa, Olga; Pūle, Daina; Lucenko, Irina; Krastiņa, Dita; Šteingolde, Žanete; Krūmiņa, Angelika; Bērziņš, Aivars

    2015-01-01

    Continuous environmental exposure of humans to Legionella may induce immune responses and generation of antibodies. The aim of this study was to investigate the seroprevalence of Legionella pneumophila serogroups (SG) 1–6 in the general healthy population and identify the associated host-related and environmental risk factors. L. pneumophila SG 1–6 seroprevalence among a total of 2007 blood samples collected from healthy donors was 4.8%. Seroprevalence was higher in women (5.9%) than men (3.3%) and in areas with a larger number of inhabitants, ranging from 3.5% in rural regions to 6.8% in the capital, Riga. Blood samples from inhabitants of apartment buildings tested positive for L. pneumophila in more cases (5.8%) compared to those from inhabitants of single-family homes (2.7%). Residents of buildings with a municipal hot water supply system were more likely to be seropositive for L. pneumophila (OR = 3.16, 95% CI 1.26–7.91). Previous episodes of fever were additionally identified as a risk factor (OR = 2.42, 95% CI 1.43–4.1). In conclusion, centralized hot water supply, female gender and previous episodes of fever were determined as the main factors associated with L. pneumophila seropositivity in our study population. PMID:26703696

  17. Recombinant Mip-PilE-FlaA dominant epitopes vaccine candidate against Legionella pneumophila.

    PubMed

    He, Jinlei; Huang, Fan; Chen, Han; Chen, Qiwei; Zhang, Junrong; Li, Jiao; Chen, Dali; Chen, Jianping

    2017-06-01

    Legionella pneumophila is the main causative agent of Legionnaires' disease, which is a severe multi-system disease with pneumonia as the primary manifestation. We designed a recombinant Mip-PilE-FlaA dominant epitopes vaccine against Legionella pneumophila to prevent the disease and evaluated its immunogenicity and protective immunity. The protein structures of Mip, PilE and FlaA were analyzed using a computer, and the gene sequences of the dominant epitopes of the three proteins were selected to construct and optimize the vaccine. The optimized mip, pilE, flaA and recombinant mip-pilE-flaA gene sequences were cloned, expressed and purified. The purified proteins were used as dominant epitopes vaccines to immunize BALB/c mice and determine the protective immunity and immunogenicity of these purified proteins. The identification confirmed that the recombinant mip-pilE-flaA was successfully cloned and expressed. ELISA revealed that the Mip-PilE-FlaA group produced the highest IgG response, and this protein may considerably improve the production of some cytokines in BALB/c mice. Histopathology analyses of lungs from mice immunized with Mip-PilE-FlaA revealed a certain protective effect. Our work demonstrated that the recombinant dominant epitopes of Mip-PilE-FlaA exhibited strong immunogenicity and immune protection, and this protein may be an efficient epitopes vaccine candidate against Legionella pneumophila. Copyright © 2017 European Federation of Immunological Societies. Published by Elsevier B.V. All rights reserved.

  18. Growth-related Metabolism of the Carbon Storage Poly-3-hydroxybutyrate in Legionella pneumophila.

    PubMed

    Gillmaier, Nadine; Schunder, Eva; Kutzner, Erika; Tlapák, Hana; Rydzewski, Kerstin; Herrmann, Vroni; Stämmler, Maren; Lasch, Peter; Eisenreich, Wolfgang; Heuner, Klaus

    2016-03-18

    Legionella pneumophila, the causative agent of Legionnaires disease, has a biphasic life cycle with a switch from a replicative to a transmissive phenotype. During the replicative phase, the bacteria grow within host cells in Legionella-containing vacuoles. During the transmissive phenotype and the postexponential (PE) growth phase, the pathogens express virulence factors, become flagellated, and leave the Legionella-containing vacuoles. Using (13)C labeling experiments, we now show that, under in vitro conditions, serine is mainly metabolized during the replicative phase for the biosynthesis of some amino acids and for energy generation. During the PE phase, these carbon fluxes are reduced, and glucose also serves as an additional carbon substrate to feed the biosynthesis of poly-3-hydroxybuyrate (PHB), an essential carbon source for transmissive L. pneumophila. Whole-cell FTIR analysis and comparative isotopologue profiling further reveal that a putative 3-ketothiolase (Lpp1788) and a PHB polymerase (Lpp0650), but not enzymes of the crotonyl-CoA pathway (Lpp0931-0933) are involved in PHB metabolism during the PE phase. However, the data also reflect that additional bypassing reactions for PHB synthesis exist in agreement with in vivo competition assays using Acanthamoeba castellannii or human macrophage-like U937 cells as host cells. The data suggest that substrate usage and PHB metabolism are coordinated during the life cycle of the pathogen. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.

  19. Titanisierung von Implantatoberflächen

    NASA Astrophysics Data System (ADS)

    Zimmermann, Hanngörg; Heinlein, Markus; Guldner, Norbert W.

    Titan gilt seit Jahrzehnten als einer der wichtigsten Implantatwerkstoffe in der Medizin. Neben den guten mechanischen Eigenschaften (Leichtigkeit, hohe Festigkeit etc.), besitzen Titanimplantate vor allem eine hervorragende Körperverträglichkeit, so dass die Implantate optimal in den humanen Organismus integriert werden [1]. Ist jedoch aufgrund der Anforderungen an das Implantat eine hohe Flexibilität und/ oder Elastizität gefragt, so scheidet der Werkstoff Titan aufgrund seiner spröden und unflexiblen Materialeigenschaften aus. Die Folge ist der Einsatz von Implantatmaterialien, sowohl künstlichen als auch biologischen Ursprungs, welche nicht selten eine unzureichende Biokompatibilität aufweisen und somit zu Fremdköper- und immunologischen Reaktionen und Einkapselung des Implantates führen können. Die Erhöhung der Körperverträglichkeit, eine Adaption an das biologische Umfeld und eine hohe Biokompatibilität sind demzufolge die wichtigsten Eigenschaften bei der bedarfsgerechten Herstellung von Implantaten und Implantatoberflächen. Zur Gestaltung von innovativen, biokompatiblen Oberflächen stehen unterschiedliche technische Lösungsansätze zur Verfügung. Zum einen besteht die Möglichkeit, geeignete Oberflächeneigenschaften aus dem Grundmaterial selbst zu optimieren. Dies geschieht unter anderem durch Modifikation der Werkstoffoberflächen in Form von Texturierungen und Oberflächenrauhigkeiten. Zum anderen können die Oberflächeneigenschaften unabhängig von denen des Trägermaterials gestaltet werden. Durch Funktionalisierung der Oberflächen mit geeigneten Beschichtungen oder der Zugabe von Medikamenten (Drug Eluting) werden die Kunststoffimplantate dahingehend verändert, dass eine Steigerung der Körperakzeptanz erreicht wird. Die Titanbeschichtung von Implantatoberflächen kombiniert die positiven Materialeigenschaften von Titan und Polymer.

  20. Wernher von Braun

    NASA Image and Video Library

    1968-01-22

    Dr. Wernher Von Braun, stands in front of a Saturn IB Launch Vehicle at Kennedy Space Center (KSC). Dr. Von Braun was Marshall's first Center Director (1960-1970). Under his leadership Marshall was responsible for the development of the Saturn rockets, the Skylab project and getting the United States into Space and landing on the moon with the Apollo missions.

  1. Structural and Functional Investigations of the Effector Protein LpiR1 from Legionella pneumophila.

    PubMed

    Beyrakhova, Ksenia A; van Straaten, Karin; Li, Lei; Boniecki, Michal T; Anderson, Deborah H; Cygler, Miroslaw

    2016-07-22

    Legionella pneumophila is a causative agent of a severe pneumonia, known as Legionnaires' disease. Legionella pathogenicity is mediated by specific virulence factors, called bacterial effectors, which are injected into the invaded host cell by the bacterial type IV secretion system. Bacterial effectors are involved in complex interactions with the components of the host cell immune and signaling pathways, which eventually lead to bacterial survival and replication inside the mammalian cell. Structural and functional studies of bacterial effectors are, therefore, crucial for elucidating the mechanisms of Legionella virulence. Here we describe the crystal structure of the LpiR1 (Lpg0634) effector protein and investigate the effects of its overexpression in mammalian cells. LpiR1 is an α-helical protein that consists of two similar domains aligned in an antiparallel fashion. The hydrophilic cleft between the domains might serve as a binding site for a potential host cell interaction partner. LpiR1 binds the phosphate group at a conserved site and is stabilized by Mn(2+), Ca(2+), or Mg(2+) ions. When overexpressed in mammalian cells, a GFP-LpiR1 fusion protein is localized in the cytoplasm. Intracellular signaling antibody array analysis revealed small changes in the phosphorylation state of several components of the Akt signaling pathway in HEK293T cells overexpressing LpiR1. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.

  2. A case of severe thrombotic thrombocytopenic purpura with concomitant Legionella pneumonia: review of pathogenesis and treatment.

    PubMed

    Talebi, Tony; Fernandez-Castro, Gustavo; Montero, Alberto J; Stefanovic, Alexandra; Lian, Eric

    2011-09-01

    Thrombotic thrombocytopenia purpura (TTP) is a severe multisystem disorder characterized by fever, microangiopathic hemolytic anemia, thrombocytopenia, neurologic symptoms, and impaired renal function. Platelet counts are usually diminished, whereas the bone marrow shows a large number of megakaryocytes indicating peripheral destruction and consumption of platelets. Coagulation studies in patients with TTP are normal or slightly elevated, which helps differentiate this entity from disseminated intravascular coagulation. The peripheral smear shows an abundance of schistocytes, reticulocytes, and, at times, nucleated red blood cells. Serum lactate dehydrogenase and indirect bilirubin are elevated as a result of mechanical destruction of red blood cells. Legionella pneumophila has been identified as a relatively common cause of both community-acquired and hospital-acquired pneumonia. An association between Legionella and TTP has only been cited once in the literature. Here we present a case of severe TTP with concurrent Legionella infection. Our patient presented with the classic clinical findings of TTP and an ADAMTS13 level of less than 5% associated with an inhibitor. After a 3-week treatment course with plasma exchange, steroids, and antibiotics, he had complete clinical recovery and his ADAMTS13 level increased to greater than 75%. (C) 2011 Lippincott Williams & Wilkins, Inc.

  3. Field evaluation of a new point-of-use faucet filter for preventing exposure to Legionella and other waterborne pathogens in health care facilities.

    PubMed

    Baron, Julianne L; Peters, Tammy; Shafer, Raymond; MacMurray, Brian; Stout, Janet E

    2014-11-01

    Opportunistic waterborne pathogens (eg, Legionella, Pseudomonas) may persist in water distribution systems despite municipal chlorination and secondary disinfection and can cause health care-acquired infections. Point-of-use (POU) filtration can limit exposure to pathogens; however, their short maximum lifetime and membrane clogging have limited their use. A new faucet filter rated at 62 days was evaluated at a cancer center in Northwestern Pennsylvania. Five sinks were equipped with filters, and 5 sinks served as controls. Hot water was collected weekly for 17 weeks and cultured for Legionella, Pseudomonas, and total bacteria. Legionella was removed from all filtered samples for 12 weeks. One colony was recovered from 1 site at 13 weeks; however, subsequent tests were negative through 17 weeks of testing. Total bacteria were excluded for the first 2 weeks, followed by an average of 1.86 log reduction in total bacteria compared with controls. No Pseudomonas was recovered from filtered or control faucets. This next generation faucet filter eliminated Legionella beyond the 62 day manufacturers' recommended maximum duration of use. These new POU filters will require fewer change-outs than standard filters and could be a cost-effective method for preventing exposure to Legionella and other opportunistic waterborne pathogens in hospitals with high-risk patients. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  4. Occurrence of Opportunistic Pathogens Legionella Pneumophilaand Non-tuberculous Mycobacteria in Hospital Plumbing Systems

    EPA Science Inventory

    Opportunistic premise plumbing pathogens (OPPPs) such as Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa are frequently detected in the plumbing systems of large buildings. The ability of these organisms to form biofilms and to grow in phagocytic amoeba ar...

  5. The dps gene of symbiotic "Candidatus Legionella jeonii" in Amoeba proteus responds to hydrogen peroxide and phagocytosis.

    PubMed

    Park, Miey; Yun, Seong Tae; Hwang, Sue-Yun; Chun, Choong-Ill; Ahn, Tae In

    2006-11-01

    To survive in host cells, intracellular pathogens or symbiotic bacteria require protective mechanisms to overcome the oxidative stress generated by phagocytic activities of the host. By genomic library tagging, we cloned a dps (stands for DNA-binding protein from starved cells) gene of the symbiotic "Candidatus Legionella jeonii" organism (called the X bacterium) (dps(X)) that grows in Amoeba proteus. The gene encodes a 17-kDa protein (pI 5.19) with 91% homology to Dps and DNA-binding ferritin-like proteins of other organisms. The cloned gene complemented the dps mutant of Escherichia coli and conferred resistance to hydrogen peroxide. Dps(X) proteins purified from E. coli transformed with the dps(X) gene were in oligomeric form, formed a complex with pBlueskript SKII DNA, and protected the DNA from DNase I digestion and H(2)O(2)-mediated damage. The expression of the dps(X) gene in "Candidatus Legionella jeonii" was enhanced when the host amoeba was treated with 2 mM H(2)O(2) and by phagocytic activities of the host cell. These results suggested that the Dps protein has a function protective of the bacterial DNA and that its gene expression responds to oxidative stress generated by phagocytic activities of the host cell. With regard to the fact that invasion of Legionella sp. into respiratory phagocytic cells causes pneumonia in mammals, further characterization of dps(X) expression in the Legionella sp. that multiplies in a protozoan host in the natural environment may provide valuable information toward understanding the protective mechanisms of intracellular pathogens.

  6. Intra-amoeba multiplication induces chemotaxis and biofilm colonization and formation for Legionella.

    PubMed

    Bigot, Renaud; Bertaux, Joanne; Frere, Jacques; Berjeaud, Jean-Marc

    2013-01-01

    Legionella pneumophila, a facultative intracellular bacterium, is the causative agent of legionellosis. In the environment this pathogenic bacterium colonizes the biofilms as well as amoebae, which provide a rich environment for the replication of Legionella. When seeded on pre-formed biofilms, L. pneumophila was able to establish and survive and was only found at the surface of the biofilms. Different phenotypes were observed when the L. pneumophila, used to implement pre-formed biofilms or to form mono-species biofilms, were cultivated in a laboratory culture broth or had grown intracellulary within the amoeba. Indeed, the bacteria, which developed within the amoeba, formed clusters when deposited on a solid surface. Moreover, our results demonstrate that multiplication inside the amoeba increased the capacity of L. pneumophila to produce polysaccharides and therefore enhanced its capacity to establish biofilms. Finally, it was shown that the clusters formed by L. pneumophila were probably related to the secretion of a chemotaxis molecular agent.

  7. Intra-Amoeba Multiplication Induces Chemotaxis and Biofilm Colonization and Formation for Legionella

    PubMed Central

    Bigot, Renaud; Bertaux, Joanne; Frere, Jacques; Berjeaud, Jean-Marc

    2013-01-01

    Legionella pneumophila, a facultative intracellular bacterium, is the causative agent of legionellosis. In the environment this pathogenic bacterium colonizes the biofilms as well as amoebae, which provide a rich environment for the replication of Legionella. When seeded on pre-formed biofilms, L. pneumophila was able to establish and survive and was only found at the surface of the biofilms. Different phenotypes were observed when the L. pneumophila, used to implement pre-formed biofilms or to form mono-species biofilms, were cultivated in a laboratory culture broth or had grown intracellulary within the amoeba. Indeed, the bacteria, which developed within the amoeba, formed clusters when deposited on a solid surface. Moreover, our results demonstrate that multiplication inside the amoeba increased the capacity of L. pneumophila to produce polysaccharides and therefore enhanced its capacity to establish biofilms. Finally, it was shown that the clusters formed by L. pneumophila were probably related to the secretion of a chemotaxis molecular agent. PMID:24205008

  8. Informatic analysis reveals Legionella as a source of novel natural products.

    PubMed

    Johnston, Chad W; Plumb, Jonathan; Li, Xiang; Grinstein, Sergio; Magarvey, Nathan A

    2016-06-01

    Microbial natural products are a crucial source of bioactive molecules and unique chemical scaffolds. Despite their importance, rediscovery of known natural products from established productive microbes has led to declining interest, even while emergent genomic data suggest that the majority of microbial natural products remain to be discovered. Now, new sources of microbial natural products must be defined in order to provide chemical scaffolds for the next generation of small molecules for therapeutic, agricultural, and industrial purposes. In this work, we use specialized bioinformatic programs, genetic knockouts, and comparative metabolomics to define the genus Legionella as a new source of novel natural products. We show that Legionella spp. hold a diverse collection of biosynthetic gene clusters for the production of polyketide and nonribosomal peptide natural products. To confirm this bioinformatic survey, we create targeted mutants of L. pneumophila and use comparative metabolomics to identify a novel polyketide surfactant. Using spectroscopic techniques, we show that this polyketide possesses a new chemical scaffold, and firmly demonstrate that this unexplored genus is a source for novel natural products.

  9. Host cell processes that influence the intracellular survival of Legionella pneumophila.

    PubMed

    Shin, Sunny; Roy, Craig R

    2008-06-01

    Key to the pathogenesis of intracellular pathogens is their ability to manipulate host cell processes, permitting the establishment of an intracellular replicative niche. In turn, the host cell deploys defence mechanisms that limit intracellular infection. The bacterial pathogen Legionella pneumophila, the aetiological agent of Legionnaire's Disease, has evolved virulence mechanisms that allow it to replicate within protozoa, its natural host. Many of these tactics also enable L. pneumophila's survival and replication inside macrophages within a membrane-bound compartment known as the Legionella-containing vacuole. One of the virulence factors indispensable for L. pneumophila's intracellular survival is a type IV secretion system, which translocates a large repertoire of bacterial effectors into the host cell. These effectors modulate multiple host cell processes and in particular, redirect trafficking of the L. pneumophila phagosome and mediate its conversion into an ER-derived organelle competent for intracellular bacterial replication. In this review, we discuss how L. pneumophila manipulates host cells, as well as host cell processes that either facilitate or impede its intracellular survival.

  10. Different distribution patterns of ten virulence genes in Legionella reference strains and strains isolated from environmental water and patients.

    PubMed

    Zhan, Xiao-Yong; Hu, Chao-Hui; Zhu, Qing-Yi

    2016-04-01

    Virulence genes are distinct regions of DNA which are present in the genome of pathogenic bacteria and absent in nonpathogenic strains of the same or related species. Virulence genes are frequently associated with bacterial pathogenicity in genus Legionella. In the present study, an assay was performed to detect ten virulence genes, including iraA, iraB, lvrA, lvrB, lvhD, cpxR, cpxA, dotA, icmC and icmD in different pathogenicity islands of 47 Legionella reference strains, 235 environmental strains isolated from water, and 4 clinical strains isolated from the lung tissue of pneumonia patients. The distribution frequencies of these genes in reference or/and environmental L. pneumophila strains were much higher than those in reference non-L. pneumophila or/and environmental non-L. pneumophila strains, respectively. L. pneumophila clinical strains also maintained higher frequencies of these genes compared to four other types of Legionella strains. Distribution frequencies of these genes in reference L. pneumophila strains were similar to those in environmental L. pneumophila strains. In contrast, environmental non-L. pneumophila maintained higher frequencies of these genes compared to those found in reference non-L. pneumophila strains. This study illustrates the association of virulence genes with Legionella pathogenicity and reveals the possible virulence evolution of non-L. pneumophia strains isolated from environmental water.

  11. Legionella jordanis lower respiratory tract infection: case report and review.

    PubMed

    Vinh, Donald C; Garceau, Richard; Martinez, Gabriela; Wiebe, Debbie; Burdz, Tamara; Reimer, Aleisha; Bernard, Kathryn

    2007-07-01

    Legionella jordanis was first described in 1982 after isolation from environmental sources and is otherwise a very rare human pathogen. Here, we report the recovery of L. jordanis from a bronchoalveolar lavage specimen from a patient who presented with an indolent lower respiratory tract infection associated with constitutional symptoms. This case is the first culture-positive case of infection involving this species in Canada.

  12. Wernher von Braun

    NASA Image and Video Library

    1970-02-24

    Dr. von Braun was honored with a series of farewell events and ceremonies prior to his reassignment to NASA Headquarters in Washington, D.C. Alabama Governor Brewer greets Dr. von Braun following his speech at the front of the Madison County Courthouse in Huntsville, Alabama on February 24, 1970. Behind are Madison County Commissioner James Record, Huntsville Mayor Joe Davis, and U.S. Senator Sparkman.

  13. Wernher von Braun

    NASA Image and Video Library

    1969-07-24

    Apollo 11 splashdown celebration in Huntsville, Alabama, on July 24, 1969. Huntsville Alabama is the home of the Marshall Space Flight Center which developed the Saturn vehicles under the direction of Dr. von Braun. The photo shows Dr. von Braun speaking to the crowd at the Madison County Courthouse as Mayor Joe Davis, Madison County Commissioner James Record and City Council President Ken Johnson look on.

  14. Wernher von Braun

    NASA Image and Video Library

    1969-07-24

    Dr. von Braun is carried aloft on the shoulders of Huntsville city officials during the Apollo 11 celebration in Huntsville, Alabama, on July 24, 1969. Huntsville, Alabama is the home of the Marshall Space Flight Center which developed the Saturn vehicles under the direction of Dr. von Braun. The Apollo 11 lifted off in July and made the first marned lunar landing on the Moon.

  15. Travel-associated infections caused by unusual serogroups of Legionella pneumophila identified using Legionella BIOCHIP slides in Turkey and Iraq.

    PubMed

    Kocazeybek, Bekir S; Yuksel, Pelin; Keskin, Dilek; Sheikh, Suhail; Habip, Zafer; Yavuzer, Serap Sahin; Caliskan, Reyhan; Altun, Yagız Meric; Kuskucu, Mert; Cengiz, Mahir; Dinc, Harika Oyku; Karakullukcu, Asiye; Ergin, Sevgi; Saribas, Suat; Yilmaz, Nail; Tokman, Hrisi Bahar

    2016-01-01

    Although Legionella pneumophila serogroup 1 is the common disease causing serogroup, rare serogroups can also may cause legionellosis. A 54-year-old male patient (index case) reported that he had been on a religious trip (for visiting, tomb of Ali, which is important for Shias) to Iraq with a large group (50 shia pilgrims from Kars city of Turkey) two weeks prior to admission. Due to civil war, the hotel where the patient stayed in Iraq lacked proper hygiene. A large number of people in the travel group were experiencing the same symptoms. Other five cases were 2 males (ages; 50, 45) and 3 females including the wife of the index case (ages; 50, 28, 27). The detection of L. pneumophila IgG and IgM was performed by anti-L. pneumophila Indirect Immunofluorescent IgM, IgG kit. Legionella 1 biochip/verification BIOCHIP slides were used for serogrouping in Euroimmun AG, Leubeck, Germany. In index case, L. pneumophila IgM was positive with a titer of 1/32 titer. IgG was negative with a 1/100 titer. Another case (28 year old female), had clinical symptoms identical to the index case. L. pneumophila IgM and IgG were positive with titers of 1/64 and 1/100, respectively. These two cases were diagnosed with Legionnaires' disease caused by L. pneumophila serogroup 12 (index case) and female (28-year-old) by serogroup 11. The other 4 cases were diagnosed with possible Pontiac fever caused by L. pneumophila serogroups 14 (wife of the index case), 4, and 6 whereas the serogroup of L. pneumophila detected in 27 years old female case could not be identified. A major limitation of this work is the absence of genotyping and the serogroup difference between index case and his wife who shared the same hotel. We suggest that this serogroup difference may be caused by (for men and women) sitting separately in Islamic rules. On the other hand, the movement of people in the context of mutual visits between countries or neighboring countries for tourism-related (i.e., for religious events

  16. [Detection of antibodies against Legionella pneumophila from pleural effusion--a case report of Legionnaire's pneumonia with pleural effusion].

    PubMed

    Xu, L; Wang, P; Chen, S

    1994-06-01

    Using TAT and ELISA, 50 samples of pleural effusion and sera from patients infected with non-Legionella pneumophila were detected for antibodies against Legionella pneumophila serogroups 1 and 6, respectively. The average titre and upper limit value (99%, mean + 2.326S) calculated. In addition, a pleural effusion and a serum from a patient with Legionnaire's pneumonia were also detected by TAT and ELISA. The result showed that the titre of this antibody in his pleural effusion was not only over the upper limit, but also higher than that in his serum.

  17. Discriminatory usefulness of pulsed-field gel electrophoresis and sequence-based typing in Legionella outbreaks.

    PubMed

    Quero, Sara; García-Núñez, Marian; Párraga-Niño, Noemí; Barrabeig, Irene; Pedro-Botet, Maria L; de Simon, Mercè; Sopena, Nieves; Sabrià, Miquel

    2016-06-01

    To compare the discriminatory power of pulsed-field gel electrophoresis (PFGE) and sequence-based typing (SBT) in Legionella outbreaks for determining the infection source. Twenty-five investigations of Legionnaires' disease were analyzed by PFGE, SBT and Dresden monoclonal antibody. The results suggested that monoclonal antibody could reduce the number of Legionella isolates to be characterized by molecular methods. The epidemiological concordance PFGE-SBT was 100%, while the molecular concordance was 64%. Adjusted Wallace index (AW) showed that PFGE has better discriminatory power than SBT (AWSBT→PFGE = 0.767; AWPFGE→SBT = 1). The discrepancies appeared mostly in sequence type (ST) 1, a worldwide distributed ST for which PFGE discriminated different profiles. SBT discriminatory power was not sufficient verifying the infection source, especially in worldwide distributed STs, which were classified into different PFGE patterns.

  18. Complete Genome Sequences of Two Geographically Distinct Legionella micdadei Clinical Isolates

    PubMed Central

    Jose, Bethany R.; Perry, Jasper; Smeele, Zoe; Aitken, Jack; Gardner, Paul P.

    2017-01-01

    ABSTRACT Legionella is a highly diverse genus of intracellular bacterial pathogens that cause Legionnaire’s disease (LD), an often severe form of pneumonia. Two L. micdadei sp. clinical isolates, obtained from patients hospitalized with LD from geographically distinct areas, were sequenced using PacBio SMRT cell technology, identifying incomplete phage regions, which may impact virulence. PMID:28572318

  19. Diagnosis and management of von Willebrand's syndrome.

    PubMed

    Rick, M E

    1994-05-01

    von Willebrand's disease is the most common of the inherited bleeding disorders. It is caused by quantitative and/or qualitative abnormalities of von Willebrand factor, and it usually presents with bleeding from mucosal surfaces. The diagnosis is confirmed by measuring von Willebrand factor activity and antigen levels, factor VIII activity, and performing a multimer analysis of von Willebrand factor. Treatment may require plasma-derived concentrates, but can often be accomplished with DDAVP, a vasopressin analogue that causes transient release of von Willebrand factor from body storage sites.

  20. Occurrence of Opportunistic Pathogens Legionella pneumophila and non-tuberculous mycobacteria in hospital plumbing systems

    EPA Science Inventory

    Occurrence of Opportunistic Pathogens Legionella pneumophila and non-tuberculous mycobacteria in hospital plumbing systems Jill Hoelle, Michael Coughlin, Elizabeth Sotkiewicz, Jingrang Lu, Stacy Pfaller, Mark Rodgers, and Hodon Ryu U.S. Environmental Protection Agency, Cincinnati...

  1. Molecular typing of Legionella pneumophila serogroup 1 clinical strains isolated in Italy.

    PubMed

    Fontana, Stefano; Scaturro, Maria; Rota, Maria Cristina; Caporali, Maria Grazia; Ricci, Maria Luisa

    2014-07-01

    Molecular typing methods for discriminating different bacterial isolates are essential epidemiological tools in prevention and control of Legionella infections and outbreaks. A selection of 56 out of 184 Legionella pneumophila serogroup 1 (Lp1) clinical isolates, collected from different Italian regions between 1987 and 2012, and stored at the National Reference Laboratory for Legionella, were typed by monoclonal antibody (MAb) subgrouping, amplified fragment length polymorphism (AFLP) and sequence based typing (SBT). These strains were isolated from 39 community (69.6%), 14 nosocomial (25%) and 3 travel associated (5.4%) Legionnaires'disease cases. MAb typing results showed a prevalence of MAb 3/1 positive isolates (75%) with the Philadelphia subgroup representing 35.7%, followed by Knoxville (23.2%), Benidorm (12.5%), Allentown/France (1.8%), Allentown/France-Philadelphia (1.8%). The remaining 25% were MAb 3/1 negative, namely 11 Olda (19.6%), 2 Oxford (3.6%) and 1 Bellingham (1.8%) subgroups. AFLP analysis detected 20 different genomic profiles. SBT analysis revealed 32 different sequence types (STs) with high diversity of STs (IODSTs=0.952) 12 of which were never described before. ST1 and ST23 were most frequently isolated as observed worldwide. A helpful analysis of data from SBT, MAb subgrouping and AFLP is provided, as well as a comparison to the Lp1 types investigated from other countries. This study describes the first Italian Lp1 strains database, providing molecular epidemiology data useful for future epidemiological investigations, especially of travel associated Legionnaires' diseases (TALD) cases, Italy being the country associated with the highest number of clusters. Copyright © 2014 Elsevier GmbH. All rights reserved.

  2. SigmaS controls multiple pathways associated with intracellular multiplication of Legionella pneumophila.

    PubMed

    Hovel-Miner, Galadriel; Pampou, Sergey; Faucher, Sebastien P; Clarke, Margaret; Morozova, Irina; Morozov, Pavel; Russo, James J; Shuman, Howard A; Kalachikov, Sergey

    2009-04-01

    Legionella pneumophila is the causative agent of the severe and potentially fatal pneumonia Legionnaires' disease. L. pneumophila is able to replicate within macrophages and protozoa by establishing a replicative compartment in a process that requires the Icm/Dot type IVB secretion system. The signals and regulatory pathways required for Legionella infection and intracellular replication are poorly understood. Mutation of the rpoS gene, which encodes sigma(S), does not affect growth in rich medium but severely decreases L. pneumophila intracellular multiplication within protozoan hosts. To gain insight into the intracellular multiplication defect of an rpoS mutant, we examined its pattern of gene expression during exponential and postexponential growth. We found that sigma(S) affects distinct groups of genes that contribute to Legionella intracellular multiplication. We demonstrate that rpoS mutants have a functional Icm/Dot system yet are defective for the expression of many genes encoding Icm/Dot-translocated substrates. We also show that sigma(S) affects the transcription of the cpxR and pmrA genes, which encode two-component response regulators that directly affect the transcription of Icm/Dot substrates. Our characterization of the L. pneumophila small RNA csrB homologs, rsmY and rsmZ, introduces a link between sigma(S) and the posttranscriptional regulator CsrA. We analyzed the network of sigma(S)-controlled genes by mutational analysis of transcriptional regulators affected by sigma(S). One of these, encoding the L. pneumophila arginine repressor homolog gene, argR, is required for maximal intracellular growth in amoebae. These data show that sigma(S) is a key regulator of multiple pathways required for L. pneumophila intracellular multiplication.

  3. Nosocomial outbreak of Legionella pneumophila serogroup 3 pneumonia in a new bone marrow transplant unit: evaluation, treatment and control.

    PubMed

    Oren, I; Zuckerman, T; Avivi, I; Finkelstein, R; Yigla, M; Rowe, J M

    2002-08-01

    A nosocomial outbreak of pneumonia caused by Legionella pneumophila serogroup 3 occurred in four patients following hematopoietic stem cell transplantation (HSCT) in a new bone marrow transplantation (BMT) unit during a 2 week period. The causative organism was recovered from the water supply system to the same unit just before the outbreak. Nineteen other BMT patients were hospitalized in the same unit at the same time, giving a frequency of proven infection of 4/23 = 17%. Immediately after recognition of the outbreak, use of tap water was forbidden, humidifiers were disconnected, and ciprofloxacin prophylaxis was started for all patients in the unit, until decontamination of the water was achieved. No other cases were detected. In conclusion, contamination of the hospital water supply system with legionella carries a high risk for legionella pneumonia among BMT patients. Early recognition of the outbreak, immediate restrictions of water use, antibiotic prophylaxis for all non-infected patients, and water decontamination, successfully terminated the outbreak.

  4. The Role of Biofilms in Drinking Water Exposure to Potentially Pathogenic Legionella spp.

    EPA Science Inventory

    Legionellosis is a bacterial infection caused by species of the genera Legionella and is the most common waterborne disease reported in the United States. This type of infection has two clinically distinct forms: Legionnaire's disease, a severe type of infection, which include...

  5. Legionella pneumophila: Virulent and Avirulent Interaction with Acanthamoeba castellanii.

    DTIC Science & Technology

    1993-08-01

    HCl 0.40 g Ferric Pryophsphate, Soluble 0.25 g ACES Buffer 10.0 g Activated Charcoal 2.0 g Alpha - Ketoglutaric Acid 1.0 g Agar 15.0 g Polyndixin B...Growth enhancement also occurs with the addition of trace metals such as calcium , cobalt, copper, magnesium, manganese, nickel, vandium and zinc (125...by the addition of ACES buffer (BCYE), (116). This formulation with the addition of a- ketoglutarate facilitates good recovery of legionellae from

  6. Bafilomycin A1 and intracellular multiplication of Legionella pneumophila.

    PubMed Central

    Cattani, L; Goldoni, P; Pastoris, M C; Sinibaldi, L; Orsi, N

    1997-01-01

    Multiplication of Legionella pneumophila in HeLa cells was found to be inhibited by noncytotoxic concentrations of bafilomycin A1, with blockage of bacterial growth at a concentration 15.6 nM. The inhibiting action was evident only when the antibiotic was present during the initial phase of intracellular multiplication, i.e., during the formation of the phagosome, whereas the addition of the drug did not affect microorganisms already actively multiplying within the phagosome. PMID:8980784

  7. Response of Legionella pneumophila to beta-lactam antibiotics.

    PubMed Central

    Weisholtz, S; Tomasz, A

    1985-01-01

    Legionella pneumophila Philadelphia strain 1 grown in vitro contained five penicillin-binding proteins that were accessible to the antibiotic in membrane preparations and in live cells as well. The bacterium had reasonably low MICs of several beta-lactam antibiotics and was susceptible to both the bactericidal and the lytic activity of these drugs. An unusual feature of the response of this bacterium to penicillin treatment was that cell lysis as determined by decrease in culture turbidity and release of intracellular macromolecules was not accompanied by degradation of the peptidoglycan. Images PMID:2409915

  8. Prevalence of Legionella species isolated from shower water in public bath facilities in Toyama Prefecture, Japan.

    PubMed

    Kanatani, Jun-Ichi; Isobe, Junko; Norimoto, Shiho; Kimata, Keiko; Mitsui, Chieko; Amemura-Maekawa, Junko; Kura, Fumiaki; Sata, Tetsutaro; Watahiki, Masanori

    2017-05-01

    We investigated the prevalence of Legionella spp. isolated from shower water in public bath facilities in Toyama Prefecture, Japan. In addition, we analyzed the genetic diversity among Legionella pneumophila isolates from shower water as well as the genetic relationship between isolates from shower water and from stock strains previously analyzed from sputum specimens. The isolates were characterized using serogrouping, 16S rRNA gene sequencing, and sequence-based typing. Legionella spp. were isolated from 31/91 (34.1%) samples derived from 17/37 (45.9%) bath facilities. Isolates from shower water and bath water in each public bath facility were serologically or genetically different, indicating that we need to isolate several L. pneumophila colonies from both bath and shower water to identify public bath facilities as sources of legionellosis. The 61 L. pneumophila isolates from shower water were classified into 39 sequence types (STs) (index of discrimination = 0.974), including 19 new STs. Among the 39 STs, 12 STs match clinical isolates in the European Working Group for Legionella Infections database. Notably, ST505 L. pneumophila SG 1, a strain frequently isolated from patients with legionellosis and from bath water in this area, was isolated from shower water. Pathogenic L. pneumophila strains including ST505 strain were widely distributed in shower water in public bath facilities, with genetic diversity showing several different origins. This study highlights the need to isolate several L. pneumophila colonies from both bath water and shower water to identify public bath facilities as infection sources in legionellosis cases. Copyright © 2017 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  9. Concentration and diversity of uncultured Legionella spp. in two unchlorinated drinking water supplies with different concentrations of natural organic matter.

    PubMed

    Wullings, Bart A; Bakker, Geo; van der Kooij, Dick

    2011-01-01

    Two unchlorinated drinking water supplies were investigated to assess the potential of water treatment and distribution systems to support the growth of Legionella spp. The treatment plant for supply A distributed treated groundwater with a low concentration (<0.5 ppm of C) of natural organic matter (NOM), and the treatment plant for supply B distributed treated groundwater with a high NOM concentration (8 ppm of C). In both supplies, the water temperature ranged from about 10°C after treatment to 18°C during distribution. The concentrations of Legionella spp. in distributed water, analyzed with quantitative PCR (Q-PCR), averaged 2.9 (± 1.9) × 10(2) cells liter(-1) in supply A and 2.5 (± 1.6) × 10(3) cells liter(-1) in supply B. No Legionella was observed with the culture method. A total of 346 clones (96 operational taxonomical units [OTUs] with ≥97% sequence similarity) were retrieved from water and biofilms of supply A and 251 (43 OTUs) from supply B. The estimation of the average value of total species richness (Chao1) in supply A (153) was clearly higher than that for supply B (58). In each supply, about 77% of the sequences showed <97% similarity to described species. Sequences related to L. pneumophila were only incidentally observed. The Legionella populations of the two supplies are divided into two distinct clusters based on distances in the phylogenetic tree as fractions of the branch length. Thus, a large variety of mostly yet-undescribed Legionella spp. proliferates in unchlorinated water supplies at temperatures below 18°C. The lowest concentration and greatest diversity were observed in the supply with the low NOM concentration.

  10. Prevalence and Molecular Characteristics of Waterborne Pathogen Legionella in Industrial Cooling Tower Environments

    PubMed Central

    Li, Lijie; Qin, Tian; Li, Yun; Zhou, Haijian; Song, Hongmei; Ren, Hongyu; Li, Liping; Li, Yongguang; Zhao, Dong

    2015-01-01

    Cooling towers are a source of Legionnaires’ disease. It is important from a public health perspective to survey industrial cooling towers for the presence of Legionella. Prospective surveillance of the extent of Legionella pollution was conducted at factories in Shijiazhuang, China between March 2011 and September 2012. Overall, 35.7% of 255 industrial cooling tower water samples showed Legionella-positive, and their concentrations ranged from 100 Colony-Forming Units (CFU)/liter to 88,000 CFU/liter, with an average concentration of 9100 CFU/liter. A total of 121 isolates were obtained. All isolates were L. pneumophila, and the isolated serogroups included serogroups 1 (68 isolates, 56.2%), 6 (25, 20.7%), 5 (12, 9.9%), 8 (8, 6.6%), 3 (6, 5.0%) and 9 (2, 1.6%). All 121 isolates were analyzed by pulsed-field gel electrophoresis (PFGE) and 64 different patterns were obtained. All 121 isolates were analyzed sequence-based typing (SBT), a full 7-allele profile was obtained from 117 isolates. One hundred and seventeen isolates were divided into 49 sequence types. Two virulence genes, lvh and rtxA, are analyzed by polymerase chain reaction (PCR). 92.6% (112/121) and 98.3% (119/121) isolates carried lvh and rtxA respectively and 90.9% (110/121) of tested isolates carried both genes. Our results demonstrated high prevalence and genetic polymorphism of L. pneumophila in industrial cooling tower environments in Shijiazhang, China, and the SBT and virulence gene PCR results suggested that the isolates were pathogenic. Improved control and prevention strategies are urgently needed. PMID:26473896

  11. Prevalence and Molecular Characteristics of Waterborne Pathogen Legionella in Industrial Cooling Tower Environments.

    PubMed

    Li, Lijie; Qin, Tian; Li, Yun; Zhou, Haijian; Song, Hongmei; Ren, Hongyu; Li, Liping; Li, Yongguang; Zhao, Dong

    2015-10-12

    Cooling towers are a source of Legionnaires' disease. It is important from a public health perspective to survey industrial cooling towers for the presence of Legionella. Prospective surveillance of the extent of Legionella pollution was conducted at factories in Shijiazhuang, China between March 2011 and September 2012. Overall, 35.7% of 255 industrial cooling tower water samples showed Legionella-positive, and their concentrations ranged from 100 Colony-Forming Units (CFU)/liter to 88,000 CFU/liter, with an average concentration of 9100 CFU/liter. A total of 121 isolates were obtained. All isolates were L. pneumophila, and the isolated serogroups included serogroups 1 (68 isolates, 56.2%), 6 (25, 20.7%), 5 (12, 9.9%), 8 (8, 6.6%), 3 (6, 5.0%) and 9 (2, 1.6%). All 121 isolates were analyzed by pulsed-field gel electrophoresis (PFGE) and 64 different patterns were obtained. All 121 isolates were analyzed sequence-based typing (SBT), a full 7-allele profile was obtained from 117 isolates. One hundred and seventeen isolates were divided into 49 sequence types. Two virulence genes, lvh and rtxA, are analyzed by polymerase chain reaction (PCR). 92.6% (112/121) and 98.3% (119/121) isolates carried lvh and rtxA respectively and 90.9% (110/121) of tested isolates carried both genes. Our results demonstrated high prevalence and genetic polymorphism of L. pneumophila in industrial cooling tower environments in Shijiazhang, China, and the SBT and virulence gene PCR results suggested that the isolates were pathogenic. Improved control and prevention strategies are urgently needed.

  12. Caspase-1 but Not Caspase-11 Is Required for NLRC4-Mediated Pyroptosis and Restriction of Infection by Flagellated Legionella Species in Mouse Macrophages and In Vivo.

    PubMed

    Cerqueira, Daiane M; Pereira, Marcelo S F; Silva, Alexandre L N; Cunha, Larissa D; Zamboni, Dario S

    2015-09-01

    Gram-negative bacteria from the Legionella genus are intracellular pathogens that cause a severe form of pneumonia called Legionnaires' disease. The bacteria replicate intracellularly in macrophages, and the restriction of bacterial replication by these cells is critical for host resistance. The activation of the NAIP5/NLRC4 inflammasome, which is readily triggered in response to bacterial flagellin, is essential for the restriction of bacterial replication in murine macrophages. Once activated, this inflammasome induces pore formation and pyroptosis and facilitates the restriction of bacterial replication in macrophages. Because investigations related to the NLRC4-mediated restriction of Legionella replication were performed using mice double deficient for caspase-1 and caspase-11, we assessed the participation of caspase-1 and caspase-11 in the functions of the NLRC4 inflammasome and the restriction of Legionella replication in macrophages and in vivo. By using several species of Legionella and mice singly deficient for caspase-1 or caspase-11, we demonstrated that caspase-1 but not caspase-11 was required for pore formation, pyroptosis, and restriction of Legionella replication in macrophages and in vivo. By generating F1 mice in a mixed 129 × C57BL/6 background deficient (129 × Casp-11(-/-) ) or sufficient (129 × C57BL/6) for caspase-11 expression, we found that caspase-11 was dispensable for the restriction of Legionella pneumophila replication in macrophages and in vivo. Thus, although caspase-11 participates in flagellin-independent noncanonical activation of the NLRP3 inflammasome, it is dispensable for the activities of the NLRC4 inflammasome. In contrast, functional caspase-1 is necessary and sufficient to trigger flagellin/NLRC4-mediated restriction of Legionella spp. infection in macrophages and in vivo. Copyright © 2015 by The American Association of Immunologists, Inc.

  13. Legionnaires' disease caused by Legionella longbeachae: Clinical features and outcomes of 107 cases from an endemic area.

    PubMed

    Isenman, Heather L; Chambers, Stephen T; Pithie, Alan D; MacDonald, Sharyn L S; Hegarty, Justin M; Fenwick, Joanna L; Maze, Michael J; Metcalf, Sarah C L; Murdoch, David R

    2016-10-01

    Legionella longbeachae is a predominant cause of Legionnaires' disease in some parts of the world, particularly in Australasia. Clinical reports of L. longbeachae infection are limited to case reports or small case series, and culture-confirmed cases. We reviewed the clinical characteristics and outcomes of L. longbeachae pneumonia in a large case series from Christchurch, New Zealand during a 4-year period when both PCR and cultures were used as routine diagnostic tools for Legionnaires' disease. Cases of Legionella pneumophila pneumonia were reviewed for comparison. A total of 107 cases of L. longbeachae infection were identified by PCR and/or culture. The median age was 65 years (range 25-90 years), 63% were male, and most became unwell during spring or summer. Presenting clinical features were similar to those reported for community-acquired pneumonia, with headache, myalgia and diarrhoea being common. Elevated C-reactive protein, hyponatraemia and abnormal liver function tests were also common. History of productive cough, involvement of both lungs, and high bacterial load were independently associated with culture of Legionella from lower respiratory samples. One quarter required intensive care unit admission, and 5% died. Among patients given antimicrobial therapy before admission, those given agents without anti-Legionella activity were more likely to be admitted to the intensive care unit. Limited comparisons were made with the 19 L. pneumophila cases over the same time period. Characteristics of L. longbeachae pneumonia are broadly similar to those reported for community-acquired pneumonia from a variety of other populations, except for the spring/summer seasonality. © 2016 Asian Pacific Society of Respirology.

  14. Multigenome analysis identifies a worldwide distributed epidemic Legionella pneumophila clone that emerged within a highly diverse species

    PubMed Central

    Cazalet, Christel; Jarraud, Sophie; Ghavi-Helm, Yad; Kunst, Frank; Glaser, Philippe; Etienne; Buchrieser, Carmen

    2008-01-01

    Genomics can provide the basis for understanding the evolution of emerging, lethal human pathogens such as Legionella pneumophila, the causative agent of Legionnaires’ disease. This bacterium replicates within amoebae and persists in the environment as a free-living microbe. Among the many Legionella species described, L. pneumophila is associated with 90% of human disease and within the 15 serogroups (Sg), L. pneumophila Sg1 causes over 84% of Legionnaires’ disease worldwide. Why L. pneumophila Sg1 is so predominant is unknown. Here, we report the first comprehensive screen of the gene content of 217 L. pneumophila and 32 non-L. pneumophila strains isolated from humans and the environment using a Legionella DNA-array. Strikingly, we uncovered a high conservation of virulence- and eukaryotic-like genes, indicating strong environmental selection pressures for their preservation. No specific hybridization profile differentiated clinical and environmental strains or strains of different serogroups. Surprisingly, the gene cluster coding the determinants of the core and the O side-chain synthesis of the lipopolysaccaride (LPS cluster) determining Sg1 was present in diverse genomic backgrounds, strongly implicating the LPS of Sg1 itself as a principal cause of the high prevalence of Sg1 strains in human disease and suggesting that the LPS cluster can be transferred horizontally. Genomic analysis also revealed that L. pneumophila is a genetically diverse species, in part due to horizontal gene transfer of mobile genetic elements among L. pneumophila strains, but also between different Legionella species. However, the genomic background also plays a role in disease causation as demonstrated by the identification of a globally distributed epidemic strain exhibiting the genotype of the sequenced L. pneumophila strain Paris. PMID:18256241

  15. Antibiotic susceptibility of Legionella pneumophila strains isolated from hospital water systems in Southern Italy.

    PubMed

    De Giglio, Osvalda; Napoli, Christian; Lovero, Grazia; Diella, Giusy; Rutigliano, Serafina; Caggiano, Giuseppina; Montagna, Maria Teresa

    2015-10-01

    The purpose of this study was to describe the susceptibility of environmental strains of Legionella spp. to 10 antimicrobials commonly used for legionellosis therapy. A study of environmental strains could be useful to timely predict the onset of antibiotic resistance in the environment before it is evidenced in clinical specimens. The minimum inhibitory concentrations (MICs) of 100 environmental Legionella pneumophila (Lpn) strains belonging to serogroups (sgs) 1, 6, 8, and 10 were tested using the E-test methodology on buffered charcoal yeast extract agar supplemented with α-ketoglutarate. The most frequent sgs were selected from those obtained during microbiological surveillance conducted in 2014 in a hospital in Southern Italy. The MICs were read after 2 days of incubation at 35 °C in a humidified atmosphere without CO2. All isolates were inhibited by low concentrations of fluoroquinolones and macrolides. Rifampicin was the most active drug against the isolates in vitro. All Lpn isolates were inhibited by the following drugs (in decreasing order of their MICs): doxycycline>tigecycline>cefotaxime. The MICs of azithromycin, ciprofloxacin, levofloxacin, moxifloxacin, and tigecycline were significantly lower for Lpn non-sg 1 than Lpn sg 1 isolates. Susceptibility testing of Legionella strains to appropriate antibiotics should be performed often to evaluate the possible emergence of resistance, to improve the outcomes of patients, and to reduce the direct costs associated with hospitalization. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  16. H-NOX Regulation of c-di-GMP Metabolism and Biofilm Formation in Legionella pneumophila

    PubMed Central

    Carlson, Hans K.; Vance, Russell E.; Marletta, Michael A.

    2010-01-01

    Summary Heme Nitric oxide/OXygen (H-NOX) domains are a family of hemoprotein sensors that are widespread in bacterial genomes, but limited information is available on their function. Legionella pneumophila is the only prokaryote found thus far to encode two H-NOX proteins. This paper presents data supporting a role for one of the Legionella pneumophila H-NOXs in the regulation of biofilm formation. In summary: (i) unmarked deletions in the hnox1 gene do not affect growth rate in liquid culture or replication in permissive macrophages; (ii) theΔhnox1 strain displays a hyper-biofilm phenotype; (iii) the gene adjacent to hnox1 is a GGDEF-EAL protein, lpg1057, and overexpression in Legionella pneumophila of this protein, or the well-studied diguanylate cyclase, vca0956, results in a hyper-biofilm phenotype; (iv) the Lpg1057 protein displays diguanylate cyclase activity in vitro and this activity is inhibited by the Hnox1 protein in the Fe(II)-NO ligation state, but not the Fe(II) unligated state; (v) consistent with the Hnox1 regulation of Lpg1057, unmarked deletions of lpg1057 in theΔhnox1 background results in reversion of the hyper-biofilm phenotype back to wild-type biofilm levels. Taken together, these results suggest a role for hnox1 in regulating c-di-GMP production by lpg1057 and biofilm formation in response to NO. PMID:20572940

  17. Combined use of real-time PCR and nested sequence-based typing in survey of human Legionella infection.

    PubMed

    Qin, T; Zhou, H; Ren, H; Shi, W; Jin, H; Jiang, X; Xu, Y; Zhou, M; Li, J; Wang, J; Shao, Z; Xu, X

    2016-07-01

    Legionnaires' disease (LD) is a globally distributed systemic infectious disease. The burden of LD in many regions is still unclear, especially in Asian countries including China. A survey of Legionella infection using real-time PCR and nested sequence-based typing (SBT) was performed in two hospitals in Shanghai, China. A total of 265 bronchoalveolar lavage fluid (BALF) specimens were collected from hospital A between January 2012 and December 2013, and 359 sputum specimens were collected from hospital B throughout 2012. A total of 71 specimens were positive for Legionella according to real-time PCR focusing on the 5S rRNA gene. Seventy of these specimens were identified as Legionella pneumophila as a result of real-time PCR amplification of the dotA gene. Results of nested SBT revealed high genetic polymorphism in these L. pneumophila and ST1 was the predominant sequence type. These data revealed that the burden of LD in China is much greater than that recognized previously, and real-time PCR may be a suitable monitoring technology for LD in large sample surveys in regions lacking the economic and technical resources to perform other methods, such as urinary antigen tests and culture methods.

  18. Effect of monochloramine treatment on colonization of a hospital water distribution system by Legionella spp.: a 1 year experience study.

    PubMed

    Mancini, Benedetta; Scurti, Maria; Dormi, Ada; Grottola, Antonella; Zanotti, Andrea; Cristino, Sandra

    2015-04-07

    Contamination of hot water distribution systems by Legionella represents a great challenge due to difficulties associated with inactivating microorganisms, preserving the water characteristics. The aim of this study was to examine over the course of 1 year in 11 fixed sites, the impact of monochloramine disinfection on Legionella, heterotrophic bacteria (36 °C), Pseudomonas aeruginosa contamination, and chemical parameters of a plumbing system in an Italian hospital. Three days after installation (T0), in the presence of monochloramine concentration between 1.5 and 2 mg/L, 10/11 sites (91%) were contaminated by L. pneumophila serogroups 3 and 10. After these results, the disinfectant dosage was increased to between 6 and 10 mg/L, reducing the level of Legionella by three logarithmic unit by 2 months postinstallation (T2) until 6 months later (T3). One year later (T4), there was a significant reduction (p = 0.0002) at 8/11 (73%) sites. Our data showed also a significant reduction of heterotrophic bacteria (36 °C) in 6/11 (55%) sites at T4 (p = 0.0004), by contrast the contamination of P. aeruginosa found at T0 in two sites persisted up until T4. The results of the present study show that monochloramine is a promising disinfectant that can prevent Legionella contamination of hospital water supplies.

  19. The dps Gene of Symbiotic “Candidatus Legionella jeonii” in Amoeba proteus Responds to Hydrogen Peroxide and Phagocytosis▿

    PubMed Central

    Park, Miey; Yun, Seong Tae; Hwang, Sue-Yun; Chun, Choong-Ill; Ahn, Tae In

    2006-01-01

    To survive in host cells, intracellular pathogens or symbiotic bacteria require protective mechanisms to overcome the oxidative stress generated by phagocytic activities of the host. By genomic library tagging, we cloned a dps (stands for DNA-binding protein from starved cells) gene of the symbiotic “Candidatus Legionella jeonii” organism (called the X bacterium) (dpsX) that grows in Amoeba proteus. The gene encodes a 17-kDa protein (pI 5.19) with 91% homology to Dps and DNA-binding ferritin-like proteins of other organisms. The cloned gene complemented the dps mutant of Escherichia coli and conferred resistance to hydrogen peroxide. DpsX proteins purified from E. coli transformed with the dpsX gene were in oligomeric form, formed a complex with pBlueskript SKII DNA, and protected the DNA from DNase I digestion and H2O2-mediated damage. The expression of the dpsX gene in “Candidatus Legionella jeonii” was enhanced when the host amoeba was treated with 2 mM H2O2 and by phagocytic activities of the host cell. These results suggested that the Dps protein has a function protective of the bacterial DNA and that its gene expression responds to oxidative stress generated by phagocytic activities of the host cell. With regard to the fact that invasion of Legionella sp. into respiratory phagocytic cells causes pneumonia in mammals, further characterization of dpsX expression in the Legionella sp. that multiplies in a protozoan host in the natural environment may provide valuable information toward understanding the protective mechanisms of intracellular pathogens. PMID:16950918

  20. Detection of Legionella, L. pneumophila and Mycobacterium Avium Complex (MAC) along Potable Water Distribution Pipelines

    PubMed Central

    Whiley, Harriet; Keegan, Alexandra; Fallowfield, Howard; Bentham, Richard

    2014-01-01

    Inhalation of potable water presents a potential route of exposure to opportunistic pathogens and hence warrants significant public health concern. This study used qPCR to detect opportunistic pathogens Legionella spp., L. pneumophila and MAC at multiple points along two potable water distribution pipelines. One used chlorine disinfection and the other chloramine disinfection. Samples were collected four times over the year to provide seasonal variation and the chlorine or chloramine residual was measured during collection. Legionella spp., L. pneumophila and MAC were detected in both distribution systems throughout the year and were all detected at a maximum concentration of 103 copies/mL in the chlorine disinfected system and 106, 103 and 104 copies/mL respectively in the chloramine disinfected system. The concentrations of these opportunistic pathogens were primarily controlled throughout the distribution network through the maintenance of disinfection residuals. At a dead-end and when the disinfection residual was not maintained significant (p < 0.05) increases in concentration were observed when compared to the concentration measured closest to the processing plant in the same pipeline and sampling period. Total coliforms were not present in any water sample collected. This study demonstrates the ability of Legionella spp., L. pneumophila and MAC to survive the potable water disinfection process and highlights the need for greater measures to control these organisms along the distribution pipeline and at point of use. PMID:25046636

  1. Detection of Legionella, L. pneumophila and Mycobacterium avium complex (MAC) along potable water distribution pipelines.

    PubMed

    Whiley, Harriet; Keegan, Alexandra; Fallowfield, Howard; Bentham, Richard

    2014-07-18

    Inhalation of potable water presents a potential route of exposure to opportunistic pathogens and hence warrants significant public health concern. This study used qPCR to detect opportunistic pathogens Legionella spp., L. pneumophila and MAC at multiple points along two potable water distribution pipelines. One used chlorine disinfection and the other chloramine disinfection. Samples were collected four times over the year to provide seasonal variation and the chlorine or chloramine residual was measured during collection. Legionella spp., L. pneumophila and MAC were detected in both distribution systems throughout the year and were all detected at a maximum concentration of 103 copies/mL in the chlorine disinfected system and 106, 103 and 104 copies/mL respectively in the chloramine disinfected system. The concentrations of these opportunistic pathogens were primarily controlled throughout the distribution network through the maintenance of disinfection residuals. At a dead-end and when the disinfection residual was not maintained significant (p < 0.05) increases in concentration were observed when compared to the concentration measured closest to the processing plant in the same pipeline and sampling period. Total coliforms were not present in any water sample collected. This study demonstrates the ability of Legionella spp., L. pneumophila and MAC to survive the potable water disinfection process and highlights the need for greater measures to control these organisms along the distribution pipeline and at point of use.

  2. A double commutant theorem for Murray–von Neumann algebras

    PubMed Central

    Liu, Zhe

    2012-01-01

    Murray–von Neumann algebras are algebras of operators affiliated with finite von Neumann algebras. In this article, we study commutativity and affiliation of self-adjoint operators (possibly unbounded). We show that a maximal abelian self-adjoint subalgebra of the Murray–von Neumann algebra associated with a finite von Neumann algebra is the Murray–von Neumann algebra , where is a maximal abelian self-adjoint subalgebra of and, in addition, is . We also prove that the Murray–von Neumann algebra with the center of is the center of the Murray–von Neumann algebra . Von Neumann’s celebrated double commutant theorem characterizes von Neumann algebras as those for which , where , the commutant of , is the set of bounded operators on the Hilbert space that commute with all operators in . At the end of this article, we present a double commutant theorem for Murray–von Neumann algebras. PMID:22543165

  3. Effect of copper and silver ionization on Legionella pneumophila eradication

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Y.E.; Vidic, R.D.; Stout, J.E.

    1995-11-01

    The presence of Legionella pneumophila in water distribution systems has been epidemiologically linked to hospital-acquired Legionnaires` disease. The objective of this study was to evaluate the efficiency of copper and silver ions for inactivation of Legionella pneumophila. Experimental results showed that L. pneumophila was completely inactivated at copper concentration of 0.1 mg/L within the period of 2.5 hours while 6-log reduction requires a Ct value of 0.8 mg/L*hour. On the other hand, more than 24 hours was required to completely eradicate L. pneumophila at the highest silver ion concentration (0.08 mg/L) tested and only 4-log reduction is observed for Ctmore » value of 0.8 mg/L*hour. The effective synergism of these ions in eradicating L. pneumophila was observed for copper concentrations of 0.05 and silver concentration of 0.04 mg/L. One approach for the control of L. pneumophila in water distribution systems is to initiate copper/silver ion concentrations at 0.4/0.04 mg/L to achieve complete eradication of L. pneumophila already present in the water distribution system (as established in previous studies) followed by a lower residual (0.05/0.04 mg/L) protection against L. pneumophila in the incoming water.« less

  4. Current and Emerging Legionella Diagnostics for Laboratory and Outbreak Investigations

    PubMed Central

    Mercante, Jeffrey W.

    2015-01-01

    SUMMARY Legionnaires' disease (LD) is an often severe and potentially fatal form of bacterial pneumonia caused by an extensive list of Legionella species. These ubiquitous freshwater and soil inhabitants cause human respiratory disease when amplified in man-made water or cooling systems and their aerosols expose a susceptible population. Treatment of sporadic cases and rapid control of LD outbreaks benefit from swift diagnosis in concert with discriminatory bacterial typing for immediate epidemiological responses. Traditional culture and serology were instrumental in describing disease incidence early in its history; currently, diagnosis of LD relies almost solely on the urinary antigen test, which captures only the dominant species and serogroup, Legionella pneumophila serogroup 1 (Lp1). This has created a diagnostic “blind spot” for LD caused by non-Lp1 strains. This review focuses on historic, current, and emerging technologies that hold promise for increasing LD diagnostic efficiency and detection rates as part of a coherent testing regimen. The importance of cooperation between epidemiologists and laboratorians for a rapid outbreak response is also illustrated in field investigations conducted by the CDC with state and local authorities. Finally, challenges facing health care professionals, building managers, and the public health community in combating LD are highlighted, and potential solutions are discussed. PMID:25567224

  5. Spatiotemporal regulation of a Legionella pneumophila T4SS substrate by the metaeffector SidJ.

    PubMed

    Jeong, Kwang Cheol; Sexton, Jessica A; Vogel, Joseph P

    2015-03-01

    Modulation of host cell function is vital for intracellular pathogens to survive and replicate within host cells. Most commonly, these pathogens utilize specialized secretion systems to inject substrates (also called effector proteins) that function as toxins within host cells. Since it would be detrimental for an intracellular pathogen to immediately kill its host cell, it is essential that secreted toxins be inactivated or degraded after they have served their purpose. The pathogen Legionella pneumophila represents an ideal system to study interactions between toxins as it survives within host cells for approximately a day and its Dot/Icm type IVB secretion system (T4SS) injects a vast number of toxins. Previously we reported that the Dot/Icm substrates SidE, SdeA, SdeB, and SdeC (known as the SidE family of effectors) are secreted into host cells, where they localize to the cytoplasmic face of the Legionella containing vacuole (LCV) in the early stages of infection. SidJ, another effector that is unrelated to the SidE family, is also encoded in the sdeC-sdeA locus. Interestingly, while over-expression of SidE family proteins in a wild type Legionella strain has no effect, we found that their over-expression in a ∆sidJ mutant completely inhibits intracellular growth of the strain. In addition, we found expression of SidE proteins is toxic in both yeast and mammalian HEK293 cells, but this toxicity can be suppressed by co-expression of SidJ, suggesting that SidJ may modulate the function of SidE family proteins. Finally, we were able to demonstrate both in vivo and in vitro that SidJ acts on SidE proteins to mediate their disappearance from the LCV, thereby preventing lethal intoxication of host cells. Based on these findings, we propose that SidJ acts as a metaeffector to control the activity of other Legionella effectors.

  6. Wernher von Braun

    NASA Image and Video Library

    1964-03-24

    Marshall Space Flight Center Director Dr. Wernher von Braun presents Lady Bird Johnson with an inscribed hard hat during the First Lady's March 24, 1964 visit. While at the Marshall Center, Mrs. Johnson addressed Center employees, toured facilities and witnessed test firings of a Saturn I first stage and an F-1 engine. Dr. von Braun is wearing a Texas hat presented to him months earlier by Lyndon Johnson during a visit to the Johnson ranch in Texas.

  7. Detection of Legionella pneumophila by PCR-ELISA method in industrial cooling tower water.

    PubMed

    Soheili, Majid; Nejadmoghaddam, Mohammad Reza; Babashamsi, Mohammad; Ghasemi, Jamileh; Jeddi Tehrani, Mahmood

    2007-11-15

    Water supply and Cooling Tower Water (CTW) are among the most common sources of Legionella pneumophila (LP) contamination. A nonradio active method is described to detect LP in industrial CTW samples. DNA was purified and amplified by nested -PCR with amplimers specific for the 16s rRNA gene of LP. The 5' end biotinylated oligomer probe was immobilized on sterptavidin B coated microtiter plates. The nested-PCR product was labeled with digoxigenin and then hybridized with 5'-biotinylated probes. The amplification products were detected by using proxidase-labled anti dioxygenin antibody in a colorimetric reaction. The assay detected LP present in 1 L of 5 CTW samples examined. All of the samples were Legionella positive in both culture and PCR-ELISA methods. The PCR-ELISA assay appears to exhibit high specificity and is a more rapid technique in comparison with bacterial culture method. Thus could prove suitable for use in the routine examination of industrial CTW contamination.

  8. The Toolbox for Uncovering the Functions of Legionella Dot/Icm Type IVb Secretion System Effectors: Current State and Future Directions

    PubMed Central

    Schroeder, Gunnar N.

    2018-01-01

    The defective in organelle trafficking/intracellular multiplication (Dot/Icm) Type IVb secretion system (T4SS) is the essential virulence factor for the intracellular life style and pathogenicity of Legionella species. Screens demonstrated that an individual L. pneumophila strain can use the Dot/Icm T4SS to translocate an unprecedented number of more than 300 proteins into host cells, where these, so called Icm/Dot-translocated substrates (IDTS) or effectors, manipulate host cell functions to the benefit of the bacteria. Bioinformatic analysis of the pan-genus genome predicts at least 608 orthologous groups of putative effectors. Deciphering the function of these effectors is key to understanding Legionella pathogenesis; however, the analysis is challenging. Substantial functional redundancy renders classical, phenotypic screening of single gene deletion mutants mostly ineffective. Here, I review experimental approaches that were successfully used to identify, validate and functionally characterize T4SS effectors and highlight new methods, which promise to facilitate unlocking the secrets of Legionella's extraordinary weapons arsenal. PMID:29354599

  9. Icm/Dot-Independent Entry of Legionella pneumophila into Amoeba and Macrophage Hosts

    PubMed Central

    Bandyopadhyay, Purnima; Xiao, Huifang; Coleman, Hope A.; Price-Whelan, Alexa; Steinman, Howard M.

    2004-01-01

    Legionella pneumophila, the causative agent of Legionnaires' disease, expresses a type IVB secretion apparatus that translocates bacterial proteins into amoeba and macrophage hosts. When stationary-phase cultures are used to infect hosts, the type IVB apparatus encoded by the icm/dot genes is required for entry, delay of phagosome-lysosome fusion, and intracellular multiplication within host cells. Null mutants with mutations in icm/dot genes are defective in these phenotypes. Here a new model is described in which hosts are infected with stationary-phase cultures that have been incubated overnight in pH 6.5 buffer. This model is called Ers treatment because it enhances the resistance to acid, hydrogen peroxide, and antibiotic stress beyond that of stationary-phase cultures. Following Ers treatment entry into amoeba and macrophage hosts does not require dotA, which is essential for Legionella virulence phenotypes when hosts are infected with stationary-phase cultures, dotB, icmF, icmV, or icmX. Defective host entry is also suppressed for null mutants with mutations in the KatA and KatB catalase-peroxidase enzymes, which are required for proper intracellular growth in amoeba and macrophage hosts. Ers treatment-induced suppression of defective entry is not associated with increased bacterial adhesion to host cells or with morphological changes in the bacterial envelope but is dependent on protein expression during Ers treatment. By using proteomic analysis, Ers treatment was shown to induce a protein predicted to contain eight tetratricopeptide repeats, a motif previously implicated in enhanced entry of L. pneumophila. Characterization of Ers treatment-dependent changes in expression is proposed as an avenue for identifying icm/dot-independent factors that function in the entry of Legionella into amoeba and macrophage hosts. PMID:15271914

  10. [Investigation of Legionella pneumophila seropositivity in the professional long distance drivers as a risky occupation].

    PubMed

    Polat, Yusuf; Ergin, Cağri; Kaleli, Ilknur; Pinar, Ahmet

    2007-04-01

    Contaminated water sources, reservoirs and systems such as evaporative condensers of air-conditioners are known to be the main transmission routes of Legionella spp. which are ubiquitous aquatic bacteria. By virtue of this point the aim of this study was to investigate the rate of Legionella pneumophila seropositivity in a profession considered as risky due to the direct and prolonged exposure to air-conditioning and air-circulating systems. For this purpose, in the period of February-August 2004 a total of 79 male subjects (63 were bus drivers and 16 were driver assistants) who were continously travelling to two different route (South part as hot climate and Middle/North parts as cold climate of Turkey) from Denizli province coach station (a province located in internal Aegian where accepted as crossroads), were included to the study. The mean age and mean working duration of bus drivers were 43.0 +/- 1.1 years and 20.0 +/- 1.1 years, respectively, while these values were 22.5 +/- 0.9 years and 4.0 +/- 0.6 years, respectively, for the drivers' assistants. The serum samples collected from the subjects were screened by a commercial indirect immunofluorescence method (Euroimmun, Germany) using L. pneumophila serogrup 1-14 antigens for the presence of specific antibodies. Additionally, air-conditioners' moisture exhaust samples of the busses in which seropositive subjects travelling with have been examined by culture and 5S rRNA gene targeted polymerase chain reaction (PCR) methods, for the presence of Legionella spp. The overall L. pneumophila seropositivity rate was detected as 15.2% (12/79). This rate was 19% (12/63) for bus drivers while all of the drivers' assistants were found seronegative. The seropositivity rate was found statistically higher in the personnel who were travelling to the hot climates (10/36, 27.8%) than those who travel to cold climates (2/43, 4.6%), (p < 0.05). The culture and PCR yielded negative results for Legionella spp. in the exhaust

  11. Epidemiology and Ecology of Opportunistic Premise Plumbing Pathogens: Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa

    EPA Science Inventory

    BACKGROUND: Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa are opportunistic premise plumbing pathogens (OPPPs) that persist and grow in household plumbing, habitats they share with humans. Infections caused by these OPPPs involve individuals with preexis...

  12. Occupational risk for Legionella infection among dental healthcare workers: meta-analysis in occupational epidemiology.

    PubMed

    Petti, Stefano; Vitali, Matteo

    2017-07-13

    The occupational risk for Legionella infection among dental healthcare workers (DHCWs) is conjectured because of the risk of routine inhalation of potentially contaminated aerosols produced by the dental instruments. Nevertheless, occupational epidemiology studies are contrasting. This meta-analysis assessed the level of scientific evidence regarding the relative occupational risk for Legionella infection among DHCWs. Literature search was performed without time and language restrictions, using broad data banks (PubMed, Scopus, Web of Science, GOOGLE Scholar) and generic keywords ('legionella' AND 'dent*'). Analytical cross-sectional studies comparing prevalence of high serum Legionella antibody levels in DHCWs and occupationally unexposed individuals were considered. The relative occupational risk was assessed through prevalence ratio (PR) with 95% CI. Between-study heterogeneity was assessed (Cochran's Q test) and was used to choose the meta-analytic method. Study quality (modified Newcastle-Ottawa Scale) and publication bias (Begg and Mazumdar's test, Egger and colleagues' test, trim and fill R 0 method) were assessed formally and considered for the sensitivity analysis. Sensitivity analysis to study inclusion, subgroup analyses (dental staff categories; publication year, before vs after 1998, ie, 5 years after the release by the Centers for Disease Control and Prevention of the infection control guidelines in dental healthcare setting) were performed. Seven studies were included (2232 DHCWs, 1172 occupationally unexposed individuals). No evidence of publication bias was detected. The pooled PR estimate was statistically non-significant at 95% level (1.7; 95% CI 0.8 to 3.2), study-quality adjustment did not change the PR considerably (PR, 1.5; 95% CI 0.5 to 4.1). PR was statistically significant before 1998 and no longer significant after 1998. Subgroup analysis according to DHCW categories was inconclusive. There is no scientific evidence that DHCWs are

  13. Differential expression of virulence genes in Legionella pneumophila growing in Acanthamoeba and human monocytes.

    PubMed

    Mou, Qianqian; Leung, Polly H M

    2018-01-01

    Legionella pneumophila, the causative agent of Legionnaires' disease, is widely distributed throughout natural and artificial water systems and can replicate in macrophages and amoebae. Amoebae are the natural hosts of L. pneumophila, whereas macrophages are incidentally infected. The life cycle of L. pneumophila comprises a replicative phase within the Legionella-containing vacuole (LCV) and a transmissive phase during which bacterial cells become motile and are released via killing of the host. Although the host death mechanisms induced by L. pneumophila have been studied, the expression patterns of related L. pneumophila genes have not been reported. The present study compared the expression patterns of host cell death-associated genes in L. pneumophila grown in the human monocytic cell line THP-1 and Acanthamoeba castellanii. Notably, when L. pneumophila was grown in THP-1, expression of the gene flaA, which is involved in the induction of pyroptosis, was downregulated during the course of infection. In contrast, sdhA associated indirectly with host death, was upregulated. Expression of the genes vipD and sidF, which are involved in the induction and suppression of apoptosis, changed by less than 2-fold. Notably, a lower percentage of pyroptotic cells was observed among infected THP-1 cells relative to uninfected cells, and the latter exhibited stronger expression of caspase-1. A different pattern was observed when L. pneumophila was grown in A. castellanii: flaA and vipD were activated, whereas sdhA and sidF were downregulated during the later stage of replication. The percentage of non-viable (annexin-V + PI + or annexin-V + PI - ) A. castellanii organisms increased with Legionella infection, and the expression of metacaspase-1, which is involved in encystation was up-regulated at late infection time. In summary, L. pneumophila can multiply intracellularly in both amoebae and macrophages to induce cell death and secondary infection, and this characteristic is

  14. Legionnaires' Disease Outbreak Caused by Endemic Strain of Legionella pneumophila, New York, New York, USA, 2015.

    PubMed

    Lapierre, Pascal; Nazarian, Elizabeth; Zhu, Yan; Wroblewski, Danielle; Saylors, Amy; Passaretti, Teresa; Hughes, Scott; Tran, Anthony; Lin, Ying; Kornblum, John; Morrison, Shatavia S; Mercante, Jeffrey W; Fitzhenry, Robert; Weiss, Don; Raphael, Brian H; Varma, Jay K; Zucker, Howard A; Rakeman, Jennifer L; Musser, Kimberlee A

    2017-11-01

    During the summer of 2015, New York, New York, USA, had one of the largest and deadliest outbreaks of Legionnaires' disease in the history of the United States. A total of 138 cases and 16 deaths were linked to a single cooling tower in the South Bronx. Analysis of environmental samples and clinical isolates showed that sporadic cases of legionellosis before, during, and after the outbreak could be traced to a slowly evolving, single-ancestor strain. Detection of an ostensibly virulent Legionella strain endemic to the Bronx community suggests potential risk for future cases of legionellosis in the area. The genetic homogeneity of the Legionella population in this area might complicate investigations and interpretations of future outbreaks of Legionnaires' disease.

  15. Legionnaires’ Disease Outbreak Caused by Endemic Strain of Legionella pneumophila, New York, New York, USA, 2015

    PubMed Central

    Nazarian, Elizabeth; Zhu, Yan; Wroblewski, Danielle; Saylors, Amy; Passaretti, Teresa; Hughes, Scott; Tran, Anthony; Lin, Ying; Kornblum, John; Morrison, Shatavia S.; Mercante, Jeffrey W.; Fitzhenry, Robert; Weiss, Don; Raphael, Brian H.; Varma, Jay K.; Zucker, Howard A.; Rakeman, Jennifer L.; Musser, Kimberlee A.

    2017-01-01

    During the summer of 2015, New York, New York, USA, had one of the largest and deadliest outbreaks of Legionnaires’ disease in the history of the United States. A total of 138 cases and 16 deaths were linked to a single cooling tower in the South Bronx. Analysis of environmental samples and clinical isolates showed that sporadic cases of legionellosis before, during, and after the outbreak could be traced to a slowly evolving, single-ancestor strain. Detection of an ostensibly virulent Legionella strain endemic to the Bronx community suggests potential risk for future cases of legionellosis in the area. The genetic homogeneity of the Legionella population in this area might complicate investigations and interpretations of future outbreaks of Legionnaires’ disease. PMID:29047425

  16. The occurrence of antibodies against Legionella pneumophila in patients with autoimmune rheumatic diseases.

    PubMed

    Sikora, Agnieszka; Koszarny, Arkadiusz; Kozioł-Montewka, Maria; Majdan, Maria; Paluch-Oleś, Jolanta; Kozioł, Małgorzata M

    2015-01-01

    Patients with autoimmune rheumatic diseases are more susceptible to infection, owing to the underlying disease itself or to its treatment. Most commonly, infections affect the respiratory and urinary tracts. One of the etiological factors of infections in these patients is the bacteria of the genus Legionella. The aim of the study was to assess the prevalence of anti-Legionella pneumophila (L. pneumophila) antibodies in patients with autoimmune rheumatic diseases and to analyze individual and environmental risk factors for the development of Legionella infection in patients with positive antibody results. The study group consisted of 165 patients with autoimmune rheumatic diseases and 100 healthy subjects. Serum samples were tested for the presence of specific antibodies in the immunoglobulin (Ig) M and IgG classes against L. pneumophila serogroups 1 to 7 (SG 1-7) and the IgG class for serogroup 1 (SG 1). Antibodies against L. pneumophila were found in 7 patients (4%): 5 cases with antibody positivity only in the IgG class and 2 cases with antibody positivity in both classes. In patients with positive IgG antibodies for SG 1-7, specific antibodies for L. pneumophila SG 1 were not detected. In the control group, positive results were obtained in 9 cases (9%): IgM positivity in 6 (6%) and IgG positivity in 3 (3%). The frequency of antibodies to L. pneumophila in our patients is comparable to that in healthy individuals. L. pneumophila should be recognized as a potential pathogen in patients with autoimmune rheumatic diseases. Primary disease condition, immunosuppressive therapy, and other risk factors should not be ignored in these patients.

  17. Inactivation of beta-lactam antibiotics by Legionella pneumophila.

    PubMed Central

    Fu, K P; Neu, H C

    1979-01-01

    Beta-lactam-inactivating activity has been found in all sero-groups of Legionella pneumophila. The beta-lactamase activity could be detected in intact cells and released by ethylenediaminetetraacetic acid treatment, indicating that it is located in the periplasmic space. The enzyme acted primarily as a cephalosporinase hydrolyzing cefamandole, cephalothin, cephaloridine, and also penicillin G and ampicillin. Cefoxitin and cefuroxime were not hydrolyzed. Clavulanic acid and CP-45,899, beta-lactamase inhibitors, prevented the hydrolysis of cephalosporins and penicillins. The beta-lactamase activity appears to be different from that found in Enterobacteriaceae and Pseudomonas. Images PMID:316686

  18. Effect of temperature and colonization of Legionella pneumophila and Vermamoeba vermiformis on bacterial community composition of copper drinking water biofilms.

    PubMed

    Buse, Helen Y; Ji, Pan; Gomez-Alvarez, Vicente; Pruden, Amy; Edwards, Marc A; Ashbolt, Nicholas J

    2017-07-01

    It is unclear how the water-based pathogen, Legionella pneumophila (Lp), and associated free-living amoeba (FLA) hosts change or are changed by the microbial composition of drinking water (DW) biofilm communities. Thus, this study characterized the bacterial community structure over a 7-month period within mature (> 600-day-old) copper DW biofilms in reactors simulating premise plumbing and assessed the impact of temperature and introduction of Lp and its FLA host, Vermamoeba vermiformis (Vv), co-cultures (LpVv). Sequence and quantitative PCR (qPCR) analyses indicated a correlation between LpVv introduction and increases in Legionella spp. levels at room temperature (RT), while at 37°C, Lp became the dominant Legionella spp. qPCR analysis suggested Vv presence may not be directly associated with Lp biofilm growth at RT and 37°C, but may contribute to or be associated with non-Lp legionellae persistence at RT. Two-way PERMANOVA and PCoA revealed that temperature was a major driver of microbiome diversity. Biofilm community composition also changed over the seven-month period and could be associated with significant shifts in dissolved oxygen, alkalinity and various metals in the influent DW. Hence, temperature, biofilm age, DW quality and transient intrusions/amplification of pathogens and FLA hosts may significantly impact biofilm microbiomes and modulate pathogen levels over extended periods. © 2016 The Authors. Microbial Biotechnology published by John Wiley & Sons Ltd and Society for Applied Microbiology.

  19. Effect of disinfectant, water age, and pipe material on occurrence and persistence of Legionella, mycobacteria, Pseudomonas aeruginosa, and two amoebas.

    PubMed

    Wang, Hong; Masters, Sheldon; Hong, Yanjuan; Stallings, Jonathan; Falkinham, Joseph O; Edwards, Marc A; Pruden, Amy

    2012-11-06

    Opportunistic pathogens represent a unique challenge because they establish and grow within drinking water systems, yet the factors stimulating their proliferation are largely unknown. The purpose of this study was to examine the influence of pipe materials, disinfectant type, and water age on occurrence and persistence of three opportunistic pathogens (Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa), broader genera (Legionella and mycobacteria), and two amoeba hosts (Acanthamoeba spp. and Hartmanella vermiformis). Triplicate simulated distribution systems (SDSs) compared iron, cement, and PVC pipe materials fed either chlorinated or chloraminated tap water and were sampled at water ages ranging from 1 day to 5.7 days. Quantitative polymerase chain reaction quantified gene copies of target microorganisms in both biofilm and bulk water. Legionella, mycobacteria, P. aeruginosa, and both amoebas naturally colonized the six SDSs, but L. pneumophila and M. avium were not detected. Disinfectant type and dose was observed to have the strongest influence on the microbiota. Disinfectant decay was noted with water age, particularly in chloraminated SDSs (due to nitrification), generally resulting in increased microbial detection frequencies and densities with water age. The influence of pipe material became apparent at water ages corresponding to low disinfectant residual. Each target microbe appeared to display a distinct response to disinfectant type, pipe materials, water age, and their interactions. Differences between the first and the second samplings (e.g., appearance of Legionella, reduction in P. aeruginosa and Acanthamoeba) suggest a temporally dynamic drinking water microbial community.

  20. Diagnostic, therapeutic and economic consequences of a positive urinary antigen test for Legionella spp. in patients admitted with community-acquired pneumonia: a 7-year retrospective evaluation.

    PubMed

    Engel, M F; van Manen, L; Hoepelman, A I M; Thijsen, S; Oosterheert, J J

    2013-09-01

    A positive urinary antigen test for Legionella spp. (Legionella urinary antigen test; LUAT) allows an early switch from empiric to targeted treatment (TT) in hospitalised, community-acquired pneumonia (CAP) patients. We aimed to evaluate the diagnostic, therapeutic and economic consequences of this frequently used test 7 years after its implementation. We retrospectively evaluated LUATs performed between 2005 and 2011 in two teaching hospitals. All tests performed in hospitalised CAP patients were used in the economic evaluation and positive tests were included in the treatment evaluation. Data on patient characteristics, admission and outcome were retrieved from the patients' files. The number of days gained by making a rapid aetiological diagnosis, the number of days TT could be provided and their costs were calculated. Of 4485 LUATs, 2504 (56%) were performed for CAP including 55 (1%) positive tests (€1041/positive test). In 26 (60%) of the 43 included positive tests, LUAT was the only test showing Legionella spp. Subsequently, earlier TT was possible in the remaining cases during 209 cumulative admission days (€274/TT day). LUAT led to detection of Legionella spp. 13 days earlier per case (€203/day) as compared with culture/serology alone. Timely LUAT use in accordance with current guidelines allows early detection and treatment of CAP caused by Legionella spp. at considerable expense.

  1. Wernher von Braun

    NASA Image and Video Library

    1958-01-31

    Jet Propulsion Laboratory Director Dr. James Pickering, Dr. James van Allen of the State University of Iowa, and Army Ballistic missionile Agency Technical Director Dr. Wernher von Braun triumphantly display a model of the Explorer I, America's first satellite, shortly after the satellite's launch on January 31, 1958. The Jet Propulsion Laboratory packed and tested the payload, a radiation detection experiment designed by Dr. van Allen. Dr. von Braun's rocket team at Redstone Arsenal in Huntsville, Alabama, developed the Juno I launch vehicle, a modified Jupiter-C.

  2. Susceptibility of Legionella pneumophila to ofloxacin in vitro and in experimental Legionella pneumonia in guinea pigs.

    PubMed Central

    Saito, A; Sawatari, K; Fukuda, Y; Nagasawa, M; Koga, H; Tomonaga, A; Nakazato, H; Fujita, K; Shigeno, Y; Suzuyama, Y

    1985-01-01

    The antimicrobial activity of ofloxacin was tested against 15 standard strains and 37 clinical and environmental strains of Legionella pneumophila by agar dilution susceptibility studies with a new growth medium. The ofloxacin MICs were inoculum dependent and ranged from 0.03 to 0.125 microgram/ml. The antibacterial activities of other agents tested relative to ofloxacin were rifampin greater than ofloxacin greater than josamycin greater than pipemidic acid. Ofloxacin, at concentrations equal to or greater than 0.05 microgram/ml, inhibited the growth of L. pneumophila grown in human monocytes. The therapeutic efficacy of ofloxacin in experimental guinea pig L. pneumophila pneumonia was greater than that observed with erythromycin or josamycin therapy; it was less effective than was rifampin. Ofloxacin was very active against intracellular L. pneumophila in these experiments and should be studied in the therapy of human Legionnaires disease. PMID:3862361

  3. Rapid detection and typing of pathogenic nonpneumophila Legionella spp. isolates using a multiplex real-time PCR assay.

    PubMed

    Benitez, Alvaro J; Winchell, Jonas M

    2016-04-01

    We developed a single tube multiplex real-time PCR assay that allows for the rapid detection and typing of 9 nonpneumophila Legionella spp. isolates that are clinically relevant. The multiplex assay is capable of simultaneously detecting and discriminating L. micdadei, L. bozemanii, L. dumoffii, L. longbeachae, L. feeleii, L. anisa, L. parisiensis, L. tucsonensis serogroup (sg) 1 and 3, and L. sainthelensis sg 1 and 2 isolates. Evaluation of the assay with nucleic acid from each of these species derived from both clinical and environmental isolates and typing strains demonstrated 100% sensitivity and 100% specificity when tested against 43 other Legionella spp. Typing of L. anisa, L. parisiensis, and L. tucsonensis sg 1 and 3 isolates was accomplished by developing a real-time PCR assay followed by high-resolution melt (HRM) analysis targeting the ssrA gene. Further typing of L. bozemanii, L. longbeachae, and L. feeleii isolates to the serogroup level was accomplished by developing a real-time PCR assay followed by HRM analysis targeting the mip gene. When used in conjunction with other currently available diagnostic tests, these assays may aid in rapidly identifying specific etiologies associated with Legionella outbreaks, clusters, sporadic cases, and potential environmental sources. Published by Elsevier Inc.

  4. Rapid on-site monitoring of Legionella pneumophila in cooling tower water using a portable microfluidic system.

    PubMed

    Yamaguchi, Nobuyasu; Tokunaga, Yusuke; Goto, Satoko; Fujii, Yudai; Banno, Fumiya; Edagawa, Akiko

    2017-06-08

    Legionnaires' disease, predominantly caused by the bacterium Legionella pneumophila, has increased in prevalence worldwide. The most common mode of transmission of Legionella is inhalation of contaminated aerosols, such as those generated by cooling towers. Simple, rapid and accurate methods to enumerate L. pneumophila are required to prevent the spread of this organism. Here, we applied a microfluidic device for on-chip fluorescent staining and semi-automated counting of L. pneumophila in cooling tower water. We also constructed a portable system for rapid on-site monitoring and used it to enumerate target bacterial cells rapidly flowing in the microchannel. A fluorescently-labelled polyclonal antibody was used for the selective detection of L. pneumophila serogroup 1 in the samples. The counts of L. pneumophila in cooling tower water obtained using the system and fluorescence microscopy were similar. The detection limit of the system was 10 4  cells/ml, but lower numbers of L. pneumophila cells (10 1 to 10 3  cells/ml) could be detected following concentration of 0.5-3 L of the water sample by filtration. Our technique is rapid to perform (1.5 h), semi-automated (on-chip staining and counting), and portable for on-site measurement, and it may therefore be effective in the initial screening of Legionella contamination in freshwater.

  5. Protein Kinase LegK2 Is a Type IV Secretion System Effector Involved in Endoplasmic Reticulum Recruitment and Intracellular Replication of Legionella pneumophila ▿

    PubMed Central

    Hervet, Eva; Charpentier, Xavier; Vianney, Anne; Lazzaroni, Jean-Claude; Gilbert, Christophe; Atlan, Danièle; Doublet, Patricia

    2011-01-01

    Legionella pneumophila is the etiological agent of Legionnaires' disease. Crucial to the pathogenesis of this intracellular pathogen is its ability to subvert host cell defenses, permitting intracellular replication in specialized vacuoles within host cells. The Dot/Icm type IV secretion system (T4SS), which translocates a large number of bacterial effectors into host cell, is absolutely required for rerouting the Legionella phagosome. Many Legionella effectors display distinctive eukaryotic domains, among which are protein kinase domains. In silico analysis and in vitro phosphorylation assays identified five functional protein kinases, LegK1 to LegK5, encoded by the epidemic L. pneumophila Lens strain. Except for LegK5, the Legionella protein kinases are all T4SS effectors. LegK2 plays a key role in bacterial virulence, as demonstrated by gene inactivation. The legK2 mutant containing vacuoles displays less-efficient recruitment of endoplasmic reticulum markers, which results in delayed intracellular replication. Considering that a kinase-dead substitution mutant of legK2 exhibits the same virulence defects, we highlight here a new molecular mechanism, namely, protein phosphorylation, developed by L. pneumophila to establish a replicative niche and evade host cell defenses. PMID:21321072

  6. Liquid Biopsy zur Überwachung von Melanompatienten.

    PubMed

    Gaiser, Maria Rita; von Bubnoff, Nikolas; Gebhardt, Christoffer; Utikal, Jochen Sven

    2018-04-01

    In den letzten sechs Jahren wurden verschiedene innovative systemische Therapien zur Behandlung des metastasierten malignen Melanoms (MM) entwickelt. Die konventionelle Chemotherapie wurde durch neuartige Primärtherapien abgelöst, darunter systemische Immuntherapien (Anti-CTLA4- und Anti-PD1-Antikörper; Zulassung von Anti-PDL1-Antikörpern erwartet) und Therapien, die gegen bestimmte Mutationen gerichtet sind (BRAF, NRAS und c-KIT). Daher stehen die behandelnden Ärzte neuen Herausforderungen gegenüber, beispielsweise der Stratifizierung von Patienten für geeignete Behandlungen und der Überwachung von Langzeit-Respondern auf Progression. Folglich werden zuverlässige Methoden zur Überwachung von Krankheitsprogression oder Behandlungsresistenz benötigt. Lokalisierte und fortgeschrittene Krebserkrankungen können zur Bildung zirkulierender Tumorzellen und Tumor-DNA (ctDNA) führen, die sich in Proben von peripherem Blut nachweisen und quantifizieren lassen (Liquid Biopsy). Im Fall von Melanompatienten können die Ergebnisse von Liquid Biopsy als neuartige prädiktive Biomarker bei therapeutischen Entscheidungen hilfreich sein, insbesondere im Zusammenhang mit mutationsbasierten zielgerichteten Therapien. Die Herausforderungen bei der Anwendung der Liquid Biopsy beinhalten strikte Kriterien für den Phänotyp der zirkulierenden MM-Zellen oder ihrer Fragmente und die Instabilität von ctDNA im Blut. In diesem Übersichtsartikel diskutieren wir die Beschränkungen der Liquid Biopsy hinsichtlich ihrer Anwendung in der Routinediagnostik. © 2018 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  7. Dr. von Braun Briefing Walt Disney

    NASA Technical Reports Server (NTRS)

    1965-01-01

    Dr. von Braun began his association with Walt Disney in the 1950s when the rocket scientist appeared in three Disney television productions related to the exploration of space. Years later, Dr. von Braun invited Disney and his associates to tour the Marshall Space Flight Center (MSFC) in Huntsville, Alabama. This photograph is dated April 13, 1965. From left are R.J. Schwinghamer from the MSFC, Disney, B.J. Bernight, and Dr. von Braun.

  8. Anti-Legionella activity of essential oil of Satureja cuneifolia.

    PubMed

    Dunkić, Valerija; Mikrut, Antonija; Bezić, Nada

    2014-05-01

    The essential oil of Satureja cuneifolia Ten. was characterized by a high concentration of the phenolic compounds carvacrol (21.3%) and thymol (9.2%). The in vitro activity of the essential oil against Legionela pneumophila serogroups (SG) I and 2-15 and Legionella spp. from different sources, using microdilution, showed that L. pneumofila is sensitive to the oil, with MICs ranging from 0.12 to 0.5%, v/v, and a MBC at 0.5 to 1%, v/v. The essential oil of S. cuneifolia was effective in the reduction of Legionellosis infections.

  9. Severe Legionnaire's disease caused by Legionella longbeachae in a long-term renal transplant patient: the importance of safe living strategies after transplantation.

    PubMed

    Wright, A J; Humar, A; Gourishankar, S; Bernard, K; Kumar, D

    2012-08-01

    Legionella species are intracellular gram-negative bacilli that require specific culture media for growth. Transplant recipients with impaired cellular immunity are at particular risk for infection with this pathogen. Most human disease is caused by Legionella pneumophila; disease caused by non-L. pneumophila species is reported mainly in immunosuppressed patients with the exception of Legionella longbeachae. L. longbeachae is a common cause of Legionnaires' disease in Australia and New Zealand, and is associated with exposure to potting soil. We report the case of a patient, 26 years post kidney transplant, who presented with severe and rapidly progressive respiratory illness. L. longbeachae serogroup 1 was isolated from respiratory cultures. Further investigation revealed that she had significant soil exposure before the onset of illness. We highlight the importance of following safe living strategies to prevent exposure-related illness even in long-term transplant recipients. © 2012 John Wiley & Sons A/S.

  10. Wernher von Braun

    NASA Image and Video Library

    1970-06-27

    This photograph was taken after Dr. von Braun moved from his post as Director of the Marshall Space Flight Center (MSFC) to Deputy Associate Administrator for Planning at NASA Headquarters. On June 27, 1970, he visited the MSFC again during the center’s 10th anniversary to look at a mockup of the spacecraft that would later be known as Skylab. With von Braun are (left to right): Herman K. Weidner, director of Science and Engineering at MSFC, and James R. Thompson of the center’s Astrionics Laboratory.

  11. Verbesserung der Symmetrie von Hirnaufnahmen entlang der Sagittalebene

    NASA Astrophysics Data System (ADS)

    Ens, Konstantin; Wenzel, Fabian; Fischer, Bernd

    Die lokale Symmetrie von Hirnscans entlang der Sagittalebene zu ermitteln und zu modizifieren, ist für eine Reihe neurologischer Anwendungen interessant. Beispielsweise kann der voxelweise Vergleich von rechter und linker Hirnhälfte nur dann Aufschluss über die Lokalisierung von Läsionen geben, wenn durch Transformation ein Hirnscan eine möglichst hohe Symmetrie aufweist. Ein weiteres Anwendungsgebiet ist die Visualisierung von medialen Hirnschnitten, für die die Trennfläche beider Hirnhälfte möglichst eben sein sollte. Diese Arbeit stellt die Entwicklung eines Verfahrens vor, mit dessen Hilfe die Symmetrie von Hirnaufnahmen entlang der Sagittalebene verbessert werden kann. Dies geschieht unter Verwendung von aktiven Konturen, die mit Hilfe einer neuartigen Kostenfunktion gesteuert werden. Experimente am Ende der Arbeit mit strukturellen Kernspinaufnahmen demonstrieren die Leistungsfähigkeit des Verfahrens.

  12. Cross-reactions between Legionella pneumophila (serogroup 1) and twenty-eight other bacterial species, including other members of the family Legionellaceae.

    PubMed Central

    Collins, M T; Espersen, F; Høiby, N; Cho, S N; Friis-Møller, A; Reif, J S

    1983-01-01

    Cross-reactions between Legionella pneumophila serogroup 1 and 28 other bacterial species were studied by various quantitative immunoelectrophoretic techniques. A sonicated L. pneumophila antigen and purified homologous rabbit antibody were used as a reference system. Few antigens (0 to 6) cross-reacted with non-Legionellaceae, but two were found in nearly all gram-negative bacteria tested (antigens no. 1 and 66). Antigen no. 66 of the L. pneumophila reference system was shown to be antigenically similar to the "common antigen" of Pseudomonas aeruginosa reported in many gram-negative bacteria. Greater than 85% of the antigens from L. pneumophila serogroup 1 cross-reacted with the other six serogroups of L. pneumophila. By contrast, Fluoribacter (Legionella) bozemanae, F. (L.) dumoffii, F. (L.) gormanii, and Tatlockia (Legionella) micdadei cross-reacted with only 45, 53, 39, and 43% of the reference system antigens, respectively. The antigenic relatedness of members of the Legionellaceae, expressed as a matching coefficient, is discussed in terms of its taxonomic significance. Serogroup-, genus-, and family-specific antigens are identified in the L. pneumophila reference system. Images PMID:6404825

  13. Legionella pneumophila pangenome reveals strain-specific virulence factors.

    PubMed

    D'Auria, Giuseppe; Jiménez-Hernández, Nuria; Peris-Bondia, Francesc; Moya, Andrés; Latorre, Amparo

    2010-03-17

    Legionella pneumophila subsp. pneumophila is a gram-negative gamma-Proteobacterium and the causative agent of Legionnaires' disease, a form of epidemic pneumonia. It has a water-related life cycle. In industrialized cities L. pneumophila is commonly encountered in refrigeration towers and water pipes. Infection is always via infected aerosols to humans. Although many efforts have been made to eradicate Legionella from buildings, it still contaminates the water systems. The town of Alcoy (Valencian Region, Spain) has had recurrent outbreaks since 1999. The strain "Alcoy 2300/99" is a particularly persistent and recurrent strain that was isolated during one of the most significant outbreaks between the years 1999-2000. We have sequenced the genome of the particularly persistent L. pneumophila strain Alcoy 2300/99 and have compared it with four previously sequenced strains known as Philadelphia (USA), Lens (France), Paris (France) and Corby (England).Pangenome analysis facilitated the identification of strain-specific features, as well as some that are shared by two or more strains. We identified: (1) three islands related to anti-drug resistance systems; (2) a system for transport and secretion of heavy metals; (3) three systems related to DNA transfer; (4) two CRISPR (Clustered Regularly Interspaced Short Palindromic Repeats) systems, known to provide resistance against phage infections, one similar in the Lens and Alcoy strains, and another specific to the Paris strain; and (5) seven islands of phage-related proteins, five of which seem to be strain-specific and two shared. The dispensable genome disclosed by the pangenomic analysis seems to be a reservoir of new traits that have mainly been acquired by horizontal gene transfer and could confer evolutionary advantages over strains lacking them.

  14. Implication of Proteins Containing Tetratricopeptide Repeats in Conditional Virulence Phenotypes of Legionella pneumophila

    PubMed Central

    Bandyopadhyay, Purnima; Sumer, Eren U.; Jayakumar, Deepak; Liu, Shuqing; Xiao, Huifang

    2012-01-01

    Legionella pneumophila, the causative agent of Legionnaires' disease, is a ubiquitous freshwater bacterium whose virulence phenotypes require a type IV secretion system (T4SS). L. pneumophila strain JR32 contains two virulence-associated T4SSs, the Dot/Icm and Lvh T4SSs. Defective entry and phagosome acidification phenotypes of dot/icm mutants are conditional and reversed by incubating broth-grown stationary-phase cultures in water (WS treatment) prior to infection, as a mimic of the aquatic environment of Legionella. Reversal of dot/icm virulence defects requires the Lvh T4SS and is associated with a >10-fold induction of LpnE, a tetratricopeptide repeat (TPR)-containing protein. In the current study, we demonstrated that defective entry and phagosome acidification phenotypes of mutants with changes in LpnE and EnhC, another TPR-containing protein, were similarly reversed by WS treatment. In contrast to dot/icm mutants for which the Lvh T4SS was required, reversal for the ΔlpnE or the ΔenhC mutant required that the other TPR-containing protein be present. The single and double ΔlpnE and ΔenhC mutants showed a hypersensitivity to sodium ion, a phenotype associated with dysfunction of the Dot/Icm T4SS. The ΔlpnE single and the ΔlpnE ΔenhC double mutant showed 3- to 9-fold increases in translocation of Dot/Icm T4SS substrates, LegS2/SplY and LepB. Taken together, these data identify TPR-containing proteins in a second mechanism by which the WS mimic of a Legionella environmental niche can reverse virulence defects of broth-grown cultures and implicate LpnE and EnhC directly or indirectly in translocation of Dot/Icm T4SS protein substrates. PMID:22563053

  15. Quantification of viable Legionella pneumophila cells using propidium monoazide combined with quantitative PCR.

    PubMed

    Yáñez, M Adela; Nocker, Andreas; Soria-Soria, Elena; Múrtula, Raquel; Martínez, Lorena; Catalán, Vicente

    2011-05-01

    One of the greatest challenges of implementing fast molecular detection methods as part of Legionella surveillance systems is to limit detection to live cells. In this work, a protocol for sample treatment with propidium monoazide (PMA) in combination with quantitative PCR (qPCR) has been optimized and validated for L. pneumophila as an alternative of the currently used time-consuming culture method. Results from PMA-qPCR were compared with culture isolation and traditional qPCR. Under the conditions used, sample treatment with 50 μM PMA followed by 5 min of light exposure were assumed optimal resulting in an average reduction of 4.45 log units of the qPCR signal from heat-killed cells. When applied to environmental samples (including water from cooling water towers, hospitals, spas, hot water systems in hotels, and tap water), different degrees of correlations between the three methods were obtained which might be explained by different matrix properties, but also varying degrees of non-culturable cells. It was furthermore shown that PMA displayed substantially lower cytotoxicity with Legionella than the alternative dye ethidium monoazide (EMA) when exposing live cells to the dye followed by plate counting. This result confirmed the findings with other species that PMA is less membrane-permeant and more selective for the intact cells. In conclusion, PMA-qPCR is a promising technique for limiting detection to intact cells and makes Legionella surveillance data substantially more relevant in comparison with qPCR alone. For future research it would be desirable to increase the method's capacity to exclude signals from dead cells in difficult matrices or samples containing high numbers of dead cells. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Simultaneous detection of Legionella species and L. anisa, L. bozemanii, L. longbeachae and L. micdadei using conserved primers and multiple probes in a multiplex real-time PCR assay.

    PubMed

    Cross, Kristen E; Mercante, Jeffrey W; Benitez, Alvaro J; Brown, Ellen W; Diaz, Maureen H; Winchell, Jonas M

    2016-07-01

    Legionnaires' disease is a severe respiratory disease that is estimated to cause between 8,000 and 18,000 hospitalizations each year, though the exact burden is unknown due to under-utilization of diagnostic testing. Although Legionella pneumophila is the most common species detected in clinical cases (80-90%), other species have also been reported to cause disease. However, little is known about Legionnaires' disease caused by these non-pneumophila species. We designed a multiplex real-time PCR assay for detection of all Legionella spp. and simultaneous specific identification of four clinically-relevant Legionella species, L. anisa, L. bozemanii, L. longbeachae, and L. micdadei, using 5'-hydrolysis probe real-time PCR. The analytical sensitivity for detection of nucleic acid from each target species was ≤50fg per reaction. We demonstrated the utility of this assay in spiked human sputum specimens. This assay could serve as a tool for understanding the scope and impact of non-pneumophila Legionella species in human disease. Published by Elsevier Inc.

  17. Community-acquired Legionella micdadei (Pittsburgh pneumonia agent) infection in Sweden.

    PubMed

    Bäck, E; Schvarcz, R; Kallings, I

    1983-01-01

    The first case of Legionella micdadei (Pittsburgh Pneumonia Agent) infection in Sweden is presented. A previously healthy 68-yr-old man fell ill with diarrhoea, fever, and mental confusion. Subsequently chest roentgenography revealed pneumonic infiltrates and a seroconversion to L. micdadei was shown. No source or transmission of infection was established. The only notable event was that the patient had been drinking rain-water from a barrel 1 day prior to his illness. An alimentary route of infection was considered.

  18. Inhibition of Legionella pneumophila multiplication within human macrophages by antimicrobial agents.

    PubMed Central

    Vildé, J L; Dournon, E; Rajagopalan, P

    1986-01-01

    The activity of serial concentrations of different antimicrobial agents on the multiplication of Legionella pneumophila within human monocyte-derived macrophages was studied. The results led to the definition of a minimal extracellular concentration inhibiting intracellular multiplication (MIEC). According to the MIECs, the antimicrobial agents tested were classified in three groups: very active (MIEC less than or equal to 0.06 microgram/ml), such as erythromycin, rifampin, and pefloxacin; active (1 microgram/ml greater than or equal to MIEC greater than or equal to 0.1 microgram/ml), such as sulfamethoxazole-trimethoprim or doxycycline; and ineffective, such as cefoxitin, which was not active within macrophages at as high as 64 micrograms/ml despite a low MIC (0.2 microgram/ml) on bacterial charcoal-yeast extract agar. The activity of netilmicin was difficult to assess because of its effect on extracellular legionellae. Combinations of erythromycin with rifampin and pefloxacin with erythromycin, rifampin, doxycycline, or netilmicin showed an additive effect and no antagonism. These results obtained in a cellular model are in agreement with the efficacy of antimicrobial agents in experimental infections and in Legionnaires disease. They sustain clinical interest in the new quinolones, such as pefloxacin, and in combinations of antimicrobial agents for the treatment of Legionnaires disease. PMID:3492176

  19. Pneumonia Updates on Legionella, Chlamydophila, and Mycoplasma Pneumonia

    PubMed Central

    Sharma, Lokesh; Losier, Ashley; Tolbert, Thomas; Dela Cruz, Charles S.; Marion, Chad R.

    2017-01-01

    SUMMARY CAP due to Legionella, Chlamydophyla, or Mycoplasma continues to be a diagnostic challenge due to the nonspecific clinical and radiographic presentations. The vague clinical presentations of atypical CAP contribute to its underdiagnosis and under-reporting. Advancements in diagnostic techniques bring hope to rapid and accurate diagnosis of atypical CAP. Macrolides and respiratory fluoroquinolones are currently the antibiotics of choice, but this may change in the near future as more antibiotics resistance patterns emerge for atypical CAP. Several controversies still exist in atypical CAP, underscoring the need for continued investigation of preventing atypical CAP and determine its association with chronic lung diseases. PMID:28159161

  20. Molecular Detection of Legionella spp. and their associations with Mycobacterium spp., Pseudomonas aeruginosa and amoeba hosts in a drinking water distribution system

    EPA Pesticide Factsheets

    Quantity of Legionella spp., Mycobacterium spp., Acanthamoeba,Vermamoeba vermiformis and Pseudomonas aeruginosa were estimated using qPCR methods.This dataset is associated with the following publication:Lu , J., I. Struewing, E. Vereen, A.E. Kirby, K. Levy, C. Moe, and N. Ashbolt. Molecular detection of Legionella spp. and their associations with Mycobacterium spp., Pseudomonas aeruginosa and amoeba hosts in a drinking water distribution system (Journal Article). JOURNAL OF APPLIED MICROBIOLOGY. Blackwell Publishing, Malden, MA, USA, 120(2): 509-521, (2016).