Sample records for wall international standard

  1. Finite element analyses for seismic shear wall international standard problem

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Y.J.; Hofmayer, C.H.

    Two identical reinforced concrete (RC) shear walls, which consist of web, flanges and massive top and bottom slabs, were tested up to ultimate failure under earthquake motions at the Nuclear Power Engineering Corporation`s (NUPEC) Tadotsu Engineering Laboratory, Japan. NUPEC provided the dynamic test results to the OECD (Organization for Economic Cooperation and Development), Nuclear Energy Agency (NEA) for use as an International Standard Problem (ISP). The shear walls were intended to be part of a typical reactor building. One of the major objectives of the Seismic Shear Wall ISP (SSWISP) was to evaluate various seismic analysis methods for concrete structuresmore » used for design and seismic margin assessment. It also offered a unique opportunity to assess the state-of-the-art in nonlinear dynamic analysis of reinforced concrete shear wall structures under severe earthquake loadings. As a participant of the SSWISP workshops, Brookhaven National Laboratory (BNL) performed finite element analyses under the sponsorship of the U.S. Nuclear Regulatory Commission (USNRC). Three types of analysis were performed, i.e., monotonic static (push-over), cyclic static and dynamic analyses. Additional monotonic static analyses were performed by two consultants, F. Vecchio of the University of Toronto (UT) and F. Filippou of the University of California at Berkeley (UCB). The analysis results by BNL and the consultants were presented during the second workshop in Yokohama, Japan in 1996. A total of 55 analyses were presented during the workshop by 30 participants from 11 different countries. The major findings on the presented analysis methods, as well as engineering insights regarding the applicability and reliability of the FEM codes are described in detail in this report. 16 refs., 60 figs., 16 tabs.« less

  2. Damping of quasi-two-dimensional internal wave attractors by rigid-wall friction

    NASA Astrophysics Data System (ADS)

    Beckebanze, F.; Brouzet, C.; Sibgatullin, I. N.; Maas, L. R. M.

    2018-04-01

    The reflection of internal gravity waves at sloping boundaries leads to focusing or defocusing. In closed domains, focusing typically dominates and projects the wave energy onto 'wave attractors'. For small-amplitude internal waves, the projection of energy onto higher wave numbers by geometric focusing can be balanced by viscous dissipation at high wave numbers. Contrary to what was previously suggested, viscous dissipation in interior shear layers may not be sufficient to explain the experiments on wave attractors in the classical quasi-2D trapezoidal laboratory set-ups. Applying standard boundary layer theory, we provide an elaborate description of the viscous dissipation in the interior shear layer, as well as at the rigid boundaries. Our analysis shows that even if the thin lateral Stokes boundary layers consist of no more than 1% of the wall-to-wall distance, dissipation by lateral walls dominates at intermediate wave numbers. Our extended model for the spectrum of 3D wave attractors in equilibrium closes the gap between observations and theory by Hazewinkel et al. (2008).

  3. Domain walls in the extensions of the Standard Model

    NASA Astrophysics Data System (ADS)

    Krajewski, Tomasz; Lalak, Zygmunt; Lewicki, Marek; Olszewski, Paweł

    2018-05-01

    Our main interest is the evolution of domain walls of the Higgs field in the early Universe. The aim of this paper is to understand how dynamics of Higgs domain walls could be influenced by yet unknown interactions from beyond the Standard Model. We assume that the Standard Model is valid up to certain, high, energy scale Λ and use the framework of the effective field theory to describe physics below that scale. Performing numerical simulations with different values of the scale Λ we are able to extend our previous analysis [1]. Our recent numerical simulations show that evolution of Higgs domain walls is rather insensitive to interactions beyond the Standard Model as long as masses of new particles are grater than 1012 GeV. For lower values of Λ the RG improved effective potential is strongly modified at field strengths crucial to the evolution of domain walls. However, we find that even for low values of Λ, Higgs domain walls decayed shortly after their formation for generic initial conditions. On the other hand, in simulations with specifically chosen initial conditions Higgs domain walls can live longer and enter the scaling regime. We also determine the energy spectrum of gravitational waves produced by decaying domain walls of the Higgs field. For generic initial field configurations the amplitude of the signal is too small to be observed in planned detectors.

  4. Standard surface grinder for precision machining of thin-wall tubing

    NASA Technical Reports Server (NTRS)

    Jones, A.; Kotora, J., Jr.; Rein, J.; Smith, S. V.; Strack, D.; Stuckey, D.

    1967-01-01

    Standard surface grinder performs precision machining of thin-wall stainless steel tubing by electrical discharge grinding. A related adaptation, a traveling wire electrode fixture, is used for machining slots in thin-walled tubing.

  5. Current situation of International Organization for Standardization/Technical Committee 249 international standards of traditional Chinese medicine.

    PubMed

    Liu, Yu-Qi; Wang, Yue-Xi; Shi, Nan-Nan; Han, Xue-Jie; Lu, Ai-Ping

    2017-05-01

    To review the current situation and progress of traditional Chinese medicine (TCM) international standards, standard projects and proposals in International Organization for Standardization (ISO)/ technical committee (TC) 249. ISO/TC 249 standards and standard projects on the ISO website were searched and new standard proposals information were collected from ISO/TC 249 National Mirror Committee in China. Then all the available data were summarized in 5 closely related items, including proposed time, proposed country, assigned working group (WG), current stage and classifification. In ISO/TC 249, there were 2 international standards, 18 standard projects and 24 new standard proposals proposed in 2014. These 44 standard subjects increased year by year since 2011. Twenty-nine of them were proposed by China, 15 were assigned to WG 4, 36 were in preliminary and preparatory stage and 8 were categorized into 4 fifields, 7 groups and sub-groups based on International Classifification Standards. A rapid and steady development of international standardization in TCM can be observed in ISO/TC 249.

  6. International Standardization of Bed Rest Standard Measures

    NASA Technical Reports Server (NTRS)

    Cromwell, Ronita L.

    2010-01-01

    This slide presentation gives an overview of the standardization of bed rest measures. The International Countermeasures Working Group attempted to define and agree internationally on standard measurements for spaceflight based bed rest studies. The group identified the experts amongst several stakeholder agencys. It included information on exercise, muscle, neurological, psychological, bone and cardiovascular measures.

  7. The International Standard for Aureomycin

    PubMed Central

    Humphrey, J. H.; Lightbown, J. W.; Mussett, M. V.; Perry, W. L. M.

    1953-01-01

    In 1950, the Department of Biological Standards, National Institute for Medical Research, London, was authorized by the WHO Expert Committee on Biological Standardization to proceed with the establishment of an International Standard for Aureomycin. A 100-g batch of aureomycin was obtained and was compared with the Standard Preparation of Aureomycin of the United States Food and Drug Administration (FDA) in a collaborative assay in which six laboratories in five countries participated. In all, 30 assays were carried out; 26 of these were done by biological methods, using Sarcina lutea, Bacillus pumilus, Staphylococcus aureus, or Bacillus cereus, and the remaining four by physicochemical methods. The results were subjected to standard methods of analysis, and the overall weighted mean potency (calculated from the biological assays only) was 1.0139, with limits of error of 99.5% to 100.5%. Since the International Standard is 1.39% more potent than the FDA Standard Preparation, it is probable that the latter contains a small amount of inert material; it is also possible that the International Standard itself is not 100% pure. For most practical purposes, however, both preparations may be regarded as substantially pure, and it is considered that to alter the present practice of quoting aureomycin dosage in metric units of weight would be inadvisable. Nevertheless, since the International Standard may not be a pure substance, a unit notation—for use where required in bioassays—is desirable, and the International Unit of Aureomycin has therefore been defined as the activity contained in one microgram of the International Standard. PMID:13141137

  8. Stress-intensity factors for a thick-walled cylinder containing an annular imbedded or external or internal surface crack

    NASA Technical Reports Server (NTRS)

    Erdol, R.; Erdogan, F.

    1976-01-01

    The elastostatic axisymmetric problem for a long thick-walled cylinder containing a ring-shaped internal or edge crack is considered. Using the standard transform technique the problem is formulated in terms of an integral equation which has a simple Cauchy kernel for the internal crack and a generalized Cauchy kernel for the edge crack as the dominant part. As examples the uniform axial load and the steady-state thermal stress problems have been solved and the related stress intensity factors have been calculated. Among other findings the results show that in the cylinder under uniform axial stress containing an internal crack the stress intensity factor at the inner tip is always greater than that at the outer tip for equal net ligament thicknesses and in the cylinder with an edge crack which is under a state of thermal stress the stress intensity factor is a decreasing function of the crack depth, tending to zero as the crack depth approaches the wall thickness.

  9. The Third International Standard for Corticotrophin

    PubMed Central

    Bangham, D. R.; Mussett, M. V.; Stack-Dunne, M. P.

    1962-01-01

    At its meeting in September 1957, the WHO Expert Committee on Biological Standardization agreed with the recommendation of the International Conference on Corticotrophin, held in July 1957, that a new international standard for corticotrophin should be set up, since the Second International Standard was made from crude material and was unsuitable for the assay of the purer preparations of corticotrophin now in general clinical use. In this paper, the authors describe the steps taken to establish the Third International Standard for Corticotrophin, from the preparation and international collaborative assay of the new material to the choice of the ”subcutaneous assay” for deriving the potency. The clinical and pharmacological implications of this choice are discussed. Since the preparation, characterization and exact quantitative assay of standards for corticotrophin are so difficult, several batches of approximately 3500 ampoules were prepared in a similar way from the same material to serve as an international Working Standard. Samples from two batches were included in the collaborative assay and found to have the same potency as the Third Standard. Sufficient ampoules of the Working Standard are available for use as national and laboratory standards. PMID:13966359

  10. The International Standard for Oxytetracycline

    PubMed Central

    Humphrey, J. H.; Lightbown, J. W.; Mussett, M. V.; Perry, W. L. M.

    1955-01-01

    The first attempt to set up an international standard for oxytetracycline, using oxytetracycline hydrochloride, failed because of difficulties in obtaining a preparation whose moisture content was uniform after distribution into ampoules. A preparation of dihydrate of oxytetracycline base was obtained instead, and was compared in an international collaborative assay with a sample of oxytetracycline hydrochloride, which was the current working standard of Chas. Pfizer & Co., Inc., USA. The results of the collaborative assay showed that the potency of the dihydrate was uniform, and that it was a suitable preparation for use as the International Standard. Evidence was obtained, however, that the reference preparation at the time of examination was less potent than had been originally supposed, and that it was hydrated. The potency of the proposed international standard was recalculated after allowance for water in the reference preparation, and the resulting biological potency agreed well with that to be expected on the basis of the physicochemical properties of the preparation. It was agreed, therefore, that the recalculated values should be used, and the preparation of oxytetracycline base dihydrate used in the collaborative assay is established as the International Standard for Oxytetracycline with a potency of 900 International Units per mg. PMID:13284563

  11. The Second International Standard for Penicillin*

    PubMed Central

    Humphrey, J. H.; Mussett, M. V.; Perry, W. L. M.

    1953-01-01

    In 1950 the Department of Biological Standards, National Institute for Medical Research, London, was authorized by the WHO Expert Committee on Biological Standardization to prepare the Second International Standard for Penicillin. A single batch of specially recrystallized sodium penicillin G was obtained and 11 laboratories in seven different countries were requested to take part in its collaborative assay. 112 assays were carried out, of which 101 were done by cup-plate methods using either Staphylococcus aureus or Bacillus subtilis. The results were subjected to standard methods of analysis, on the basis of which the authors define the Second International Standard for Penicillin as containing 1,670 International Units (IU) per mg, with limits of error (P = 0.05) of 1,666-1,674 IU/mg. The International Unit is therefore redefined as the activity contained in 0.0005988 mg of the Second International Standard for Penicillin. PMID:13082387

  12. Study of Hygrothermal Processes in External Walls with Internal Insulation

    NASA Astrophysics Data System (ADS)

    Biseniece, Edite; Freimanis, Ritvars; Purvins, Reinis; Gravelsins, Armands; Pumpurs, Aivars; Blumberga, Andra

    2018-03-01

    Being an important contributor to the final energy consumption, historic buildings built before 1945 have high specific heating energy consumption compared to current energy standards and norms. However, they often cannot be insulated from the outside due to their heritage and culture value. Internal insulation is an alternative. However internal insulation faces challenges related to hygrothermal behaviour leading to mold growth, freezing, deterioration and other risks. The goal of this research is to link hygrothermal simulation results with experimental results for internally insulated historic brick masonry to assess correlation between simulated and measured data as well as the most influential parameters. The study is carried out by both a mathematical simulation tool and laboratory tests of historic masonry with internal insulation with four insulation materials (mineral wool, EPS, wood fiber and granulated aerogel) in a cold climate (average 4000 heating degree days). We found disparity between measured and simulated hygrothermal performance of studied constructions due to differences in material parameters and initial conditions of materials. The latter plays a more important role than material parameters. Under a steady state of conditions, the condensate tolerating system varies between 72.7 % and 80.5 % relative humidity, but in condensate limiting systems relative humidity variates between 73.3 % and 82.3 %. The temperature between the masonry wall and all insulation materials has stabilized on average at +10 °C. Mold corresponding to Mold index 3 was discovered on wood fiber mat.

  13. International aerospace standards - An overview

    NASA Astrophysics Data System (ADS)

    Mason, J. L.

    1983-10-01

    Factors to be considered in adopting and extending international standards in the U.S. aerospace industry are reviewed. Cost-related advantages and disadvantages of standardization are weighed, and further obstacles are identified in the English/metric rivalry and the pacing of metrification. The problem of standard duplication is examined, and the issue of revenues from the sale of copyrighted documents describing standards is addressed. It is recommended that international metric-system standards be introduced, with proper timing, wherever possible, and that prompt negotiations be undertaken to prevent or resolve document-sales disagreements. The continuation of English-system standards for safety-related cockpit readouts and communications systems is suggested.

  14. International standards in mitigating trade risks.

    PubMed

    Thiermann, A B

    2011-04-01

    This paper describes the role of the World Organisation for Animal Health (OIE), as a science-based and democratic standard-setting organisation that provides guidance on preventing the spread of animal diseases, including zoonoses, in international trade. The World Trade Organization is identified as the international institution with the legal power to encourage adherence to international standards and mediate trade disputes. The importance of assuring good governance and the credibility of national Veterinary Services through a process of official certification is identified as an essential component in the safety of trade. Private-public partnerships and the evolution of responsibilities are also identified as essential for the implementation of health guarantees such as compartmentalisation. The rapid emergence of private standards is described as a potential complement to the implementation of sanitary standards, as long as they are applied globally and in support of the OIE standards. Ultimately, the biggest challenge is for the international community to create the incentives and generate the political will for fair trade and for the universal recognition and application of the established international sanitary standards.

  15. INTERNATIONAL REPORTS: New International Standards for Quantities and Units

    NASA Astrophysics Data System (ADS)

    Thor, A. J.

    1994-01-01

    Each coherent system of units is based on a system of quantities in such a way that the equations between the numerical values expressed in coherent units have exactly the same form, including numerical factors, as the corresponding equations between the quantities. The highest international body responsible for the International System of Units (SI) is the Conférence Générale des Poids et Mesures (CGPM). However, the CGPM is not concerned with quantities or systems of quantities. That question lies within the scope of Technical Committee number twelve of the International Organization for Standardization (ISO/TC 12). Quantities, units, symbols, conversion factors. To fulfil its responsibility, ISO/TC 12 has prepared the International Standard ISO 31, Quantities and Units, which consists of fourteen parts. The new editions of the different parts of the International Standard are briefly presented here.

  16. Performance and quality-control standards for composite floor, wall, and truss framing

    Treesearch

    Gerald A. Koenigshof

    1985-01-01

    Users must be assured that composite structural members are satisfactory for their intended purposes. Standards are provided for strength, stiffness, durability, and dimensional stability of composite floor, wall, and truss-framing members. Methods for enforcing compliance with the standards are suggested.

  17. 78 FR 63873 - Minimum Internal Control Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-25

    ... Internal Control Standards AGENCY: National Indian Gaming Commission, Interior. ACTION: Final rule. SUMMARY: The National Indian Gaming Commission (NIGC) amends its minimum internal control standards for Class... Internal Control Standards. 64 FR 590. The rule added a new part to the Commission's regulations...

  18. 78 FR 11793 - Minimum Internal Control Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-20

    ... Internal Control Standards AGENCY: National Indian Gaming Commission. ACTION: Proposed rule. SUMMARY: The National Indian Gaming Commission (NIGC) proposes to amend its minimum internal control standards for Class... NIGC published a final rule in the Federal Register called Minimum Internal Control Standards. 64 FR...

  19. 77 FR 32444 - Minimum Internal Control Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-01

    ... Internal Control Standards AGENCY: National Indian Gaming Commission. ACTION: Proposed rule. SUMMARY: The National Indian Gaming Commission (NIGC) proposes to amend its minimum internal control standards for Class... the Federal Register called Minimum Internal Control Standards. 64 FR 590. The rule added a new part...

  20. Third International Standard for Posterior Pituitary

    PubMed Central

    Bangham, D. R.; Mussett, Marjorie V.

    1958-01-01

    In October 1955, stocks of the Second International Standard for Posterior Pituitary were running low and the Department of Biological Standards of the National Institute for Medical Research, London, was asked to proceed with the arrangements for an international collaborative assay of material for the Third Standard. A single 142-g batch of posterior-pituitary-lobe powder was obtained and distributed in ampoules, in approximately 30-mg quantities. Samples were sent to 19 laboratories in 10 countries. In all, 185 assays were carried out, 122 for oxytocic activity, 53 for vasopressor activity and 10 for antidiuretic activity. On the basis of the results, which were analysed statistically at the National Institute for Medical Research, it was agreed that the potency of the Third Standard (re-named International Standard for Oxytocic, Vasopressor and Antidiuretic Substances in 1956, in view of the recent synthesis of oxytocin and vasopressin) should be expressed as 2.0 International Units per milligram. The International Unit therefore remains unchanged as 0.5 mg of the dry powder. PMID:13585079

  1. 77 FR 43196 - Minimum Internal Control Standards and Technical Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-24

    ... NATIONAL INDIAN GAMING COMMISSION 25 CFR Parts 543 and 547 Minimum Internal Control Standards [email protected] . SUPPLEMENTARY INFORMATION: Part 543 addresses minimum internal control standards (MICS) for Class II gaming operations. The regulations require tribes to establish controls and implement...

  2. The second international standard for polymyxin B.

    PubMed

    Lightbown, J W; Thomas, A H; Grab, B; Outschoorn, A S

    1973-01-01

    Since supplies of the first International Standard for Polymyxin B were exhausted, it was replaced by a second international standard the potency of which was estimated from the results of a collaborative assay carried out by 5 laboratories in 4 countries. The wide variations in the results probably resulted from difficulties experienced in handling the first international standard. The potency finally agreed upon by the collaborating laboratories, on the basis of the overall mean values obtained after rejection of the most discrepant assays, was 8 403 IU/mg. That value was accepted by the WHO Expert Committee on Biological Standardization (1970), which consequently defined the International Unit of polymyxin B as the activity contained in 0.000119 mg of the second international standard.

  3. The second international standard for polymyxin B*

    PubMed Central

    Lightbown, J. W.; Thomas, A. H.; Grab, B.; Outschoorn, A. S.

    1973-01-01

    Since supplies of the first International Standard for Polymyxin B were exhausted, it was replaced by a second international standard the potency of which was estimated from the results of a collaborative assay carried out by 5 laboratories in 4 countries. The wide variations in the results probably resulted from difficulties experienced in handling the first international standard. The potency finally agreed upon by the collaborating laboratories, on the basis of the overall mean values obtained after rejection of the most discrepant assays, was 8 403 IU/mg. That value was accepted by the WHO Expert Committee on Biological Standardization (1970), which consequently defined the International Unit of polymyxin B as the activity contained in 0.000119 mg of the second international standard. PMID:4350877

  4. Status of international optical disk standards

    NASA Astrophysics Data System (ADS)

    Chen, Di; Neumann, John

    1999-11-01

    Optical technology for data storage offers media removability with unsurpassed reliability. As the media are removable, data interchange between the media and drives from different sources is a major concern. The optical recording community realized, at the inception of this new storage technology development, that international standards for all optical recording disk/cartridge must be established to insure the healthy growth of this industry and for the benefit of the users. Many standards organizations took up the challenge and numerous international standards were established which are now being used world-wide. This paper provides a brief summary of the current status of the international optical disk standards.

  5. The international standard for colistin*

    PubMed Central

    Lightbown, J. W.; Bond, J. M.; Grab, B.

    1973-01-01

    An International Standard for Colistin has been established and the International Unit defined as the activity contained in 0.00004878 mg of this preparation. The unit was defined on the basis of a collaborative assay in which nine laboratories from six different countries participated. The material used to prepare the international standard had been manufactured in Japan; it was shown to have a composition similar to that of material produced in Europe and to be suitable for the assay of colistin from the existing sources of manufacture. PMID:4541149

  6. Intraoperative CT in the assessment of posterior wall acetabular fracture stability.

    PubMed

    Cunningham, Brian; Jackson, Kelly; Ortega, Gil

    2014-04-01

    Posterior wall acetabular fractures that involve 10% to 40% of the posterior wall may or may not require an open reduction and internal fixation. Dynamic stress examination of the acetabular fracture under fluoroscopy has been used as an intraoperative method to assess joint stability. The aim of this study was to demonstrate the value of intraoperative ISO computed tomography (CT) examination using the Siemens ISO-C imaging system (Siemens Corp, Malvern, Pennsylvania) in the assessment of posterior wall acetabular fracture stability during stress examination under anesthesia. In 5 posterior wall acetabular fractures, standard fluoroscopic images (including anteroposterior pelvis and Judet radiographs) with dynamic stress examinations were compared with the ISO-C CT imaging system to assess posterior wall fracture stability during stress examination. After review of standard intraoperative fluoroscopic images under dynamic stress examination, all 5 cases appeared to demonstrate posterior wall stability; however, when the intraoperative images from the ISO-C CT imaging system demonstrated that 1 case showed fracture instability of the posterior wall segment during stress examination, open reduction and internal fixation was performed. The use of intraoperative ISO CT imaging has shown an initial improvement in the surgeon's ability to assess the intraoperative stability of posterior wall acetabular fractures during stress examination when compared with standard fluoroscopic images. Copyright 2014, SLACK Incorporated.

  7. 77 FR 58707 - Minimum Internal Control Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-21

    ... Gaming Commission 25 CFR Part 543 Minimum Internal Control Standards; Final Rule #0;#0;Federal Register... Control Standards AGENCY: National Indian Gaming Commission, Interior. ACTION: Final rule. SUMMARY: The National Indian Gaming Commission (NIGC) amends its minimum internal control standards for Class II gaming...

  8. Novel application of internal obturator and semitendinosus muscle flaps for rectal wall repair or reinforcement.

    PubMed

    Riggs, J; Ladlow, J F; Owen, L J; Hall, J L

    2018-01-29

    Internal obturator and/or semitendinosus muscle flaps were used to reinforce primary appositional rectal wall repair in three dogs and one cat in this case series. All three dogs incurred rectal wall compromise during surgical excision of anal sac tumours. The cat sustained bite wounds to the perianal region resulting in abscessation and a rectal tear. Our results indicate that application of an internal obturator and/or semitendinosus muscle flap can reduce the risk of rectal wall dehiscence after primary repair, and consequently the risk of pararectal abscess or rectocutaneous fistula formation. © 2018 British Small Animal Veterinary Association.

  9. Labyrinths, columns and cavities: new internal features of pollen grain walls in the Acanthaceae detected by FIB-SEM.

    PubMed

    House, Alisoun; Balkwill, Kevin

    2016-03-01

    External pollen grain morphology has been widely used in the taxonomy and systematics of flowering plants, especially the Acanthaceae which are noted for pollen diversity. However internal pollen wall features have received far less attention due to the difficulty of examining the wall structure. Advancing technology in the field of microscopy has made it possible, with the use of a focused ion beam-scanning electron microscope (FIB-SEM), to view the structure of pollen grain walls in far greater detail and in three dimensions. In this study the wall structures of 13 species from the Acanthaceae were investigated for features of potential systematic relevance. FIB-SEM was applied to obtain precise cross sections of pollen grains at selected positions for examining the wall ultrastructure. Exploratory studies of the exine have thus far identified five basic structural types. The investigations also show that similar external pollen wall features may have a distinctly different internal structure. FIB-SEM studies have revealed diverse internal pollen wall features which may now be investigated for their systematic and functional significance.

  10. The International Standard for Anti-Brucella abortus Serum

    PubMed Central

    Stableforth, A. W.

    1954-01-01

    In field trials on the eradication of brucellosis from dairy herds in Great Britain, which began in 1933, a serum standard of reference was used for the examination of agglutinating suspensions prepared in different laboratories. In 1937, the Office International des Epizooties (OIE) adopted this standard and made recommendations for its use internationally. These recommendations were revised by OIE in 1948, by the Third Inter-American Congress on Brucellosis and by the Joint FAO/WHO Expert Panel on Brucellosis in 1950, and again by the latter body in 1952. A new batch equivalent in potency to the original standard was established by the WHO Expert Committee on Biological Standardization in 1952 as the International Standard for Anti-Brucella abortus Serum. The International Standard, or a national standard of equivalent potency, ensures comparability of the titres obtained in different countries by different methods, and the results of such comparisons can be expressed in a simple manner by describing the titres in terms of International Units of Brucella antibody. PMID:13199656

  11. Influence of the internal wall thickness of electrical capacitance tomography sensors on image quality

    NASA Astrophysics Data System (ADS)

    Liang, Shiguo; Ye, Jiamin; Wang, Haigang; Wu, Meng; Yang, Wuqiang

    2018-03-01

    In the design of electrical capacitance tomography (ECT) sensors, the internal wall thickness can vary with specific applications, and it is a key factor that influences the sensitivity distribution and image quality. This paper will discuss the effect of the wall thickness of ECT sensors on image quality. Three flow patterns are simulated for wall thicknesses of 2.5 mm to 15 mm on eight-electrode ECT sensors. The sensitivity distributions and potential distributions are compared for different wall thicknesses. Linear back-projection and Landweber iteration algorithms are used for image reconstruction. Relative image error and correlation coefficients are used for image evaluation using both simulation and experimental data.

  12. Housekeeping genes as internal standards: use and limits.

    PubMed

    Thellin, O; Zorzi, W; Lakaye, B; De Borman, B; Coumans, B; Hennen, G; Grisar, T; Igout, A; Heinen, E

    1999-10-08

    Quantitative studies are commonly realised in the biomedical research to compare RNA expression in different experimental or clinical conditions. These quantifications are performed through their comparison to the expression of the housekeeping gene transcripts like glyceraldehyde-3-phosphate dehydrogenase (G3PDH), albumin, actins, tubulins, cyclophilin, hypoxantine phsophoribosyltransferase (HRPT), L32. 28S, and 18S rRNAs are also used as internal standards. In this paper, it is recalled that the commonly used internal standards can quantitatively vary in response to various factors. Possible variations are illustrated using three experimental examples. Preferred types of internal standards are then proposed for each of these samples and thereafter the general procedure concerning the choice of an internal standard and the way to manage its uses are discussed.

  13. Occupational Standards: International Perspectives.

    ERIC Educational Resources Information Center

    Oliveira, Joao, Ed.

    These nine papers from a conference of the International Research Network for Training and Development focus on occupational classification, standards, and certification. "Introduction" (Joao Oliveria) presents synopses with highlights from the papers. Part I offers an overview of recent developments in the United States in…

  14. 75 FR 19944 - International Code Council: The Update Process for the International Codes and Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-16

    ... for Residential Construction in High Wind Areas. ICC 700: National Green Building Standard. The... Codes and Standards that are comprehensive, coordinated, and necessary to regulate the built environment... International Codes and Standards consist of the following: ICC Codes International Building Code. International...

  15. Overview and comparative study of GPR international standards and guidelines - COST Action TU1208

    NASA Astrophysics Data System (ADS)

    Pajewski, Lara; Marciniak, Marian; Benedetto, Andrea; Tosti, Fabio

    2016-04-01

    Ground Penetrating Radar (GPR) can be effectively used for non-destructive testing of composite structures and diagnostics affecting the whole life-cycle of civil engineering works. Nevertheless, few recognised international standards exist in this field and inhomogeneous recommendations are present in different countries. Moreover, the levels of knowledge, awareness and experience regarding the use of GPR in civil engineering vary strongly across different European areas. The COST Action TU1208 is working hard on leveraging these differences, by sharing and disseminating knowledge and experience, as well as by developing guidelines and protocols for a safe and effective use of GPR in civil engineering. GPR users need to know which is the best way to conduct GPR measurements and what the quality level for the results should be. The TU1208 guidelines will ensure a higher efficiency and quality of GPR services and they will constitute a scientific basis for the introduction of European Standards on the application of GPR in civil engineering. The aim of this contribution is to present an in-depth overview and critical analysis of the existing GPR international and national standards and guidelines. The main documents considered in our work are listed and briefly described in the following. Three standards are provided by the American Society for Testing and Materials (ASTM), to guide the GPR use for subsurface investigation, evaluation of asphalt-covered concrete bridge decks, and determination of pavement-layer thickness: 1. ASTM D6432-11, Standard Guide for Using the Surface Ground Penetrating Radar Method for Subsurface Investigation, ASTM International, West Conshohocken, PA, 2011, www.astm.org, DOI: 10.1520/D6432-11. 2. ASTM D6087-08, Standard Test Method for Evaluating Asphalt-Covered Concrete Bridge Decks Using Ground Penetrating Radar, ASTM International, West Conshohocken, PA, 2008, www.astm.org, DOI: 10.1520/D6087-08. 3. ASTM D4748-10, Standard Test Method

  16. International Organization for Standardization (ISO) 15189

    PubMed Central

    Schneider, Frank; Friedberg, Richard C.

    2017-01-01

    The College of American Pathologists (CAP) offers a suite of laboratory accreditation programs, including one specific to accreditation to the international organization for standardization (ISO) 15189 standard for quality management specific to medical laboratories. CAP leaders offer an overview of ISO 15189 including its components, internal audits, occurrence management, document control, and risk management. The authors provide a comparison of its own ISO 15189 program, CAP 15189, to the CAP Laboratory Accreditation Program. The authors conclude with why laboratories should use ISO 15189. PMID:28643484

  17. The influence of international standards on optomechanical design

    NASA Astrophysics Data System (ADS)

    Parks, Robert E.

    1992-12-01

    In the last 10 to 15 years, a considerable body of international standards literature has been published on both mechanical and optical design. We discuss the influence of these internationally developed standards on the design and fabrication of optical systems. We conclude that while there are large benefits to be gained from using these international standards, there will have to be a substantial educational effort at all levels from project scientist to worker on the shop floor to take advantage of the benefits. Many sources to help in this education process are outlined.

  18. International Organization for Standardization (ISO) 15189.

    PubMed

    Schneider, Frank; Maurer, Caroline; Friedberg, Richard C

    2017-09-01

    The College of American Pathologists (CAP) offers a suite of laboratory accreditation programs, including one specific to accreditation to the international organization for standardization (ISO) 15189 standard for quality management specific to medical laboratories. CAP leaders offer an overview of ISO 15189 including its components, internal audits, occurrence management, document control, and risk management. The authors provide a comparison of its own ISO 15189 program, CAP 15189, to the CAP Laboratory Accreditation Program. The authors conclude with why laboratories should use ISO 15189. © The Korean Society for Laboratory Medicine.

  19. Standardized sign-out reduces intern perception of medical errors on the general internal medicine ward.

    PubMed

    Salerno, Stephen M; Arnett, Michael V; Domanski, Jeremy P

    2009-01-01

    Prior research on reducing variation in housestaff handoff procedures have depended on proprietary checkout software. Use of low-technology standardization techniques has not been widely studied. We wished to determine if standardizing the process of intern sign-out using low-technology sign-out tools could reduce perception of errors and missing handoff data. We conducted a pre-post prospective study of a cohort of 34 interns on a general internal medicine ward. Night interns coming off duty and day interns reassuming care were surveyed on their perception of erroneous sign-out data, mistakes made by the night intern overnight, and occurrences unanticipated by sign-out. Trainee satisfaction with the sign-out process was assessed with a 5-point Likert survey. There were 399 intern surveys performed 8 weeks before and 6 weeks after the introduction of a standardized sign-out form. The response rate was 95% for the night interns and 70% for the interns reassuming care in the morning. After the standardized form was introduced, night interns were significantly (p < .003) less likely to detect missing sign-out data including missing important diseases, contingency plans, or medications. Standardized sign-out did not significantly alter the frequency of dropped tasks or missed lab and X-ray data as perceived by the night intern. However, the day teams thought there were significantly less perceived errors on the part of the night intern (p = .001) after introduction of the standardized sign-out sheet. There was no difference in mean Likert scores of resident satisfaction with sign-out before and after the intervention. Standardized written sign-out sheets significantly improve the completeness and effectiveness of handoffs between night and day interns. Further research is needed to determine if these process improvements are related to better patient outcomes.

  20. 46 CFR 108.503 - Relationship to international standards.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Relationship to international standards. 108.503 Section 108.503 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Lifesaving Equipment § 108.503 Relationship to international standards. For...

  1. 46 CFR 133.03 - Relationship to international standards.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Relationship to international standards. 133.03 Section 133.03 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS LIFESAVING SYSTEMS General § 133.03 Relationship to international standards. This subpart and subpart B of...

  2. 46 CFR 133.03 - Relationship to international standards.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Relationship to international standards. 133.03 Section 133.03 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS LIFESAVING SYSTEMS General § 133.03 Relationship to international standards. This subpart and subpart B of...

  3. 46 CFR 133.03 - Relationship to international standards.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Relationship to international standards. 133.03 Section 133.03 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS LIFESAVING SYSTEMS General § 133.03 Relationship to international standards. This subpart and subpart B of...

  4. 46 CFR 133.03 - Relationship to international standards.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Relationship to international standards. 133.03 Section 133.03 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS LIFESAVING SYSTEMS General § 133.03 Relationship to international standards. This subpart and subpart B of...

  5. Using FTIR-ATR Spectroscopy to Teach the Internal Standard Method

    ERIC Educational Resources Information Center

    Bellamy, Michael K.

    2010-01-01

    The internal standard method is widely applied in quantitative analyses. However, most analytical chemistry textbooks either omit this topic or only provide examples of a single-point internal standardization. An experiment designed to teach students how to prepare an internal standard calibration curve is described. The experiment is a modified…

  6. 78 FR 18321 - International Code Council: The Update Process for the International Codes and Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-26

    ... for Residential Construction in High Wind Regions. ICC 700: National Green Building Standard The..., coordinated, and necessary to regulate the built environment. Federal agencies frequently use these codes and... International Codes and Standards consist of the following: ICC Codes International Building Code. International...

  7. EPA STANDARDS NETWORK FACT SHEET: ISO 14000: INTERNATIONAL ENVIRONMENTAL MANAGEMENT STANDARDS

    EPA Science Inventory

    This flyer provides an overview of the ISO 14000 series of International standards, supplying a brief history, structure of the Technical Committee (TC) 207, structure of the U.S. Technical Advisory Group (TAG) to ISO TC-207, status of the Standards development as of June 1997, w...

  8. International Standard Payload Rack volume

    NASA Technical Reports Server (NTRS)

    2001-01-01

    Outer dimensions of the International Standard Payload Rack (ISPR) that will be used on the International Space Station (ISS) sets the envelope for scientists designing hardware for experiments in biological and physical sciences aboard ISS. The ISPR includes attachments to ISS utilities (electrical power, heating and cooling, data, fluids, vacuum, etc.) through standoffs that hold the racks in place in the lab modules. Usage will range from facilities that take entire racks to specialized drawers occupying a portion of a rack.

  9. Operations and Plans: International Military Rationalization, Standardization, and Interoperability

    DTIC Science & Technology

    1989-02-15

    Army Regulation 34–1 Operations and Plans International Military Rationalization , Standardization, and Interoperability Headquarters Department of...YYYY) 15-02-1997 2. REPORT TYPE 3. DATES COVERED (FROM - TO) xx-xx-1997 to xx-xx-1997 4. TITLE AND SUBTITLE International Military Rationalization ...DSN 427-9007 Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39.18 SUMMARY of CHANGE AR 34–1 International Military Rationalization

  10. International Standardization of Library and Documentation Techniques.

    ERIC Educational Resources Information Center

    International Federation for Documentation, The Hague (Netherlands).

    This comparative study of the national and international standards, rules and regulations on library and documentation techniques adopted in various countries was conducted as a preliminary step in determining the minimal bases for facilitating national and international cooperation between documentalists and librarians. The study compares and…

  11. Replacement of the International Standard for Tetanus Antitoxin and the Use of the Standard in the Flocculation Test

    PubMed Central

    Spaun, J.; Lyng, J.

    1970-01-01

    Since 1935 the International Unit for Tetanus Antitoxin has been defined as the activity contained in a certain weight of the first International Standard for Tetanus Antitoxin. As stocks of this standard had become depleted, 11 laboratories in 8 countries were requested to participate in a collaborative assay of a preparation proposed as a replacement. The assay results were analysed and presented to the WHO Expert Committee on Biological Standardization in 1969 which established the preparation studied as the second International Standard for Tetanus Antitoxin and defined the International Unit for Tetanus Antitoxin as the activity contained in 0.03384 mg of the second International Standard for Tetanus Antitoxin. This definition would ensure the continuity of the size of this international unit. The analysis of the collaborative studies also showed that the second International Standard for Tetanus Antitoxin has suitable properties for use in the flocculation test for the determination of the antigen content of tetanus toxoids in Lf values. The designation Lf-equivalent is described and the problems relating to the use of this term for the expression of results of in vitro assays are analysed in relation to the use of international units for expressing results of in vivo assays. As the second International Standard for Tetanus Antitoxin has an in vivo/in vitro ratio of 1.4, the Lf-equivalent of this antitoxin is 1.4 times less than its unitage. PMID:5310949

  12. International documentary standards and comparison of national physical measurement standards for the calibration of accelerometers

    NASA Astrophysics Data System (ADS)

    Evans, David J.

    2002-11-01

    The documentary standards defining internationally adopted methodologies and protocols for calibrating transducers used to measure vibration are currently developed under the International Organization for Standardization (ISO) Technical Committee 108 Sub Committee 3 (Use and calibration of vibration and shock measuring instruments). Recent revisions of the documentary standards on primary methods for the calibration of accelerometers used to measure rectilinear motion have been completed. These standards can be, and have been, used as references in the technical protocols of key international and regional comparisons between National Measurement Institutes (NMIs) on the calibration of accelerometers. These key comparisons are occurring in part as a result of the creation of the Mutual Recognition Arrangement between NMIs which has appendices that document the uncertainties, and the comparisons completed in support of the uncertainties, claimed by the National Laboratories that are signatories of the MRA. The measurements for the first international and the first Interamerican System of Metrology (SIM) regional key comparisons in vibration have been completed. These intercomparisons were promulgated via the relatively new Consultative Committee for Acoustics, Ultrasound and Vibration (CCAUV) of the International Committee for Weights and Measures (CIPM) and SIM Metrology Working Group (MWG) 9, respectively.

  13. IPDA PDS4 Project: Towards an International Planetary Data Standard

    NASA Astrophysics Data System (ADS)

    Martinez, Santa; Roatsch, Thomas; Capria, Maria Teresa; Heather, David; Yamamoto, Yukio; Hughes, Steven; Stein, Thomas; Cecconi, Baptiste; Prashar, Ajay; Batanov, Oleg; Gopala Krishna, Barla

    2016-07-01

    The International Planetary Data Alliance (IPDA) is an international collaboration of space agencies with the main objective of facilitating discovery, access and use of planetary data managed across international boundaries. For this purpose, the IPDA has adopted the NASA's Planetary Data System (PDS) standard as the de-facto archiving standard, and is working towards the internationalisation of the new generation of the standards, called PDS4. PDS4 is the largest upgrade in the history of the PDS, and is a significant step towards an online, distributed, model-driven and service-oriented architecture international archive. Following the successful deployment of PDS4 to support NASA's LADEE and MAVEN missions, PDS4 was endorsed by IPDA in 2014. This has led to the adoption of PDS4 by a number of international space agencies (ESA, JAXA, ISRO and Roscosmos, among others) for their upcoming missions. In order to closely follow the development of the PDS4 standards and to coordinate the international contribution and participation in its evolution, a group of experts from each international agency is dedicated to review different aspects of the standards and to capture recommendations and requirements to ensure the international needs are met. The activities performed by this group cover the assessment and implementation of all aspects of PDS4, including its use, documentation, tools, validation strategies and information model. This contribution will present the activities carried out by this group and how this partnership between PDS and IPDA provides an excellent foundation towards an international platform for planetary science research.

  14. Brief International Cognitive Assessment for MS (BICAMS): international standards for validation.

    PubMed

    Benedict, Ralph H B; Amato, Maria Pia; Boringa, Jan; Brochet, Bruno; Foley, Fred; Fredrikson, Stan; Hamalainen, Paivi; Hartung, Hans; Krupp, Lauren; Penner, Iris; Reder, Anthony T; Langdon, Dawn

    2012-07-16

    An international expert consensus committee recently recommended a brief battery of tests for cognitive evaluation in multiple sclerosis. The Brief International Cognitive Assessment for MS (BICAMS) battery includes tests of mental processing speed and memory. Recognizing that resources for validation will vary internationally, the committee identified validation priorities, to facilitate international acceptance of BICAMS. Practical matters pertaining to implementation across different languages and countries were discussed. Five steps to achieve optimal psychometric validation were proposed. In Step 1, test stimuli should be standardized for the target culture or language under consideration. In Step 2, examiner instructions must be standardized and translated, including all information from manuals necessary for administration and interpretation. In Step 3, samples of at least 65 healthy persons should be studied for normalization, matched to patients on demographics such as age, gender and education. The objective of Step 4 is test-retest reliability, which can be investigated in a small sample of MS and/or healthy volunteers over 1-3 weeks. Finally, in Step 5, criterion validity should be established by comparing MS and healthy controls. At this time, preliminary studies are underway in a number of countries as we move forward with this international assessment tool for cognition in MS.

  15. Standards: The Keys to Domestic and International Competitiveness.

    ERIC Educational Resources Information Center

    Hunter, Robert D.

    1993-01-01

    Demonstrates the importance of standards for the competitiveness of U.S. companies and for international trade. The value of standards in research and development, marketing, design, purchasing, manufacturing, installation, and service is explained. Examples of specific standards and their application to the computer industry are included. (10…

  16. Interrogating Identity: The International Standard School in Indonesia

    ERIC Educational Resources Information Center

    Sakhiyya, Zulfa

    2011-01-01

    This paper examines the impact of the International Standard School (ISS) on the identity of Indonesia as a postcolonial nation. According to the Indonesian Ministry of National Education, an ISS is "a school which complies with the National Standard of Education and enriches its standards from the Organisation for Economic Cooperation and…

  17. CTEPP STANDARD OPERATING PROCEDURE FOR PREPARATION OF SURROGATE RECOVERY STANDARD AND INTERNAL STANDARD SOLUTIONS FOR NEUTRAL TARGET ANALYTES (SOP-5.25)

    EPA Science Inventory

    This standard operating procedure describes the method used for preparing internal standard, surrogate recovery standard and calibration standard solutions for neutral analytes used for gas chromatography/mass spectrometry analysis.

  18. Issues concerning international comparison of free-field calibrations of acoustical standards

    NASA Astrophysics Data System (ADS)

    Nedzelnitsky, Victor

    2002-11-01

    Primary free-field calibrations of laboratory standard microphones by the reciprocity method establish these microphones as reference standard devices for calibrating working standard microphones, other measuring microphones, and practical instruments such as sound level meters and personal sound exposure meters (noise dosimeters). These primary, secondary, and other calibrations are indispensable to the support of regulatory requirements, standards, and product characterization and quality control procedures important for industry, commerce, health, and safety. International Electrotechnical Commission (IEC) Technical Committee 29 Electroacoustics produces international documentary standards, including standards for primary and secondary free-field calibration and measurement procedures and their critically important application to practical instruments. This paper addresses some issues concerning calibrations, standards activities, and the international key comparison of primary free-field calibrations of IEC-type LS2 laboratory standard microphones that is being planned by the Consultative Committee for Acoustics, Ultrasound, and Vibration (CCAUV) of the International Committee for Weights and Measures (CIPM). This comparison will include free-field calibrations by the reciprocity method at participating major national metrology laboratories throughout the world.

  19. 25 CFR 542.32 - What are the minimum internal control standards for internal audit for Tier B gaming operations?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for internal audit for Tier B gaming operations? 542.32 Section 542.32 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.32 What are the minimum internal control standards for...

  20. 25 CFR 542.22 - What are the minimum internal control standards for internal audit for Tier A gaming operations?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 25 Indians 2 2012-04-01 2012-04-01 false What are the minimum internal control standards for internal audit for Tier A gaming operations? 542.22 Section 542.22 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.22 What are the minimum internal control standards for...

  1. 25 CFR 542.22 - What are the minimum internal control standards for internal audit for Tier A gaming operations?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for internal audit for Tier A gaming operations? 542.22 Section 542.22 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.22 What are the minimum internal control standards for...

  2. 25 CFR 542.22 - What are the minimum internal control standards for internal audit for Tier A gaming operations?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for internal audit for Tier A gaming operations? 542.22 Section 542.22 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.22 What are the minimum internal control standards for...

  3. 25 CFR 542.22 - What are the minimum internal control standards for internal audit for Tier A gaming operations?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 25 Indians 2 2011-04-01 2011-04-01 false What are the minimum internal control standards for internal audit for Tier A gaming operations? 542.22 Section 542.22 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.22 What are the minimum internal control standards for...

  4. 25 CFR 542.32 - What are the minimum internal control standards for internal audit for Tier B gaming operations?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 25 Indians 2 2011-04-01 2011-04-01 false What are the minimum internal control standards for internal audit for Tier B gaming operations? 542.32 Section 542.32 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.32 What are the minimum internal control standards for...

  5. 25 CFR 542.32 - What are the minimum internal control standards for internal audit for Tier B gaming operations?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 25 Indians 2 2012-04-01 2012-04-01 false What are the minimum internal control standards for internal audit for Tier B gaming operations? 542.32 Section 542.32 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.32 What are the minimum internal control standards for...

  6. 25 CFR 542.32 - What are the minimum internal control standards for internal audit for Tier B gaming operations?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for internal audit for Tier B gaming operations? 542.32 Section 542.32 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.32 What are the minimum internal control standards for...

  7. The international development of forensic science standards - A review.

    PubMed

    Wilson-Wilde, Linzi

    2018-04-16

    Standards establish specifications and procedures designed to ensure products, services and systems are safe, reliable and consistently perform as intended. Standards can be used in the accreditation of forensic laboratories or facilities and in the certification of products and services. In recent years there have been various international activities aiming at developing forensic science standards and guidelines. The most significant initiative currently underway within the global forensic community is the development of International Organization for Standardization (ISO) standards. This paper reviews the main bodies working on standards for forensic science, the processes used and the implications for accreditation. This paper specifically discusses the work of ISO Technical Committee TC272, the future TC272 work program for the development of forensic science standards and associated timelines. Also discussed, are the lessons learnt to date in navigating the complex environment of multi-country stakeholder deliberations in standards development. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  8. Radiation safety standards and their application: international policies and current issues.

    PubMed

    González, Abel J

    2004-09-01

    This paper briefly describes the current policies of the United Nations Scientific Committee on the Effects of Atomic Radiation and the International Commission on Radiological Protection and how these policies are converted into international radiation safety standards by the International Atomic Energy Agency, which is the only global organization-within the United Nations family of international agencies-with a statutory mandate not only to establish such standards but also to provide for their application. It also summarizes the current status of the established corpus of such international standards, and of it foreseeable evolution, as well as of legally binding undertakings by countries around the world that are linked to these standards. Moreover, this paper also reviews some major current global issues related to the application of international standards, including the following: strengthening of national infrastructures for radiation safety, including technical cooperation programs for assisting developing countries; occupational radiation safety challenges, including the protection of pregnant workers and their unborn children, dealing with working environments with high natural radiation levels, and occupational attributability of health effects (probability of occupational causation); restricting discharges of radioactive substances into the environment: reviewing current international policies vis-a-vis the growing concern on the radiation protection of the "environment;" radiological protection of patients undergoing radiodiagnostic and radiotherapeutic procedures: the current International Action Plan; safety and security of radiation sources: post-11 September developments; preparedness and response to radiation emergencies: enhancing the international network; safe transport of radioactive materials: new apprehensions; safety of radioactive waste management: concerns and connections with radiation protection; and radioactive residues remaining

  9. Advancements in internationally accepted standards for radiation processing

    NASA Astrophysics Data System (ADS)

    Farrar, Harry; Derr, Donald D.; Vehar, David W.

    1993-10-01

    Three subcommittees of the American Society for Testing and Materials (ASTM) are developing standards on various aspects of radiation processing. Subcommittee E10.01 "Dosimetry for Radiation Processing" has published 9 standards on how to select and calibrate dosimeters, where to put them, how many to use, and how to use individual types of dosimeter systems. The group is also developing standards on how to use gamma, electron beam, and x-ray facilities for radiation processing, and a standard on how to treat dose uncertainties. Efforts are underway to promote inclusion of these standards into procedures now being developed by government agencies and by international groups such as the United Nations' International Consultative Group on Food Irradiation (ICGFI) in order to harmonize regulations and help avoid trade barriers. Subcommittee F10.10 "Food Processing and Packaging" has completed standards on good irradiation practices for meat and poultry and for fresh fruits, and is developing similar standards for the irradiation of seafood and spices. These food-related standards are based on practices previously published by ICGFI. Subcommittee E10.07 on "Radiation Dosimetry for Radiation Effects on Materials and Devices" principally develops standards for determining doses for radiation hardness testing of electronics. Some, including their standards on the Fricke and TLD dosimetry systems are equally useful in other radiation processing applications.

  10. 46 CFR 199.03 - Relationship to international standards.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Relationship to international standards. 199.03 Section 199.03 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) LIFESAVING APPLIANCES AND ARRANGEMENTS LIFESAVING SYSTEMS FOR CERTAIN INSPECTED VESSELS General § 199.03 Relationship to international...

  11. A review of the International Atomic Energy Agency (IAEA) international standards for tissue banks.

    PubMed

    Morales Pedraza, Jorge; Lobo Gajiwala, Astrid; Martinez Pardo, María Esther

    2012-03-01

    The IAEA International Standards for Tissue Banks published in 2003 were based on the Standards then currently in use in the USA and the European Union, among others, and reflect the best practices associated with the operation of a tissue bank. They cover legal, ethical and regulatory controls as well as requirements and procedures from donor selection and tissue retrieval to processing and distribution of finished tissue for clinical use. The application of these standards allows tissue banks to operate with the current good tissue practice, thereby providing grafts of high quality that satisfy the national and international demand for safe and biologically useful grafts. The objective of this article is to review the IAEA Standards and recommend new topics that could improve the current version.

  12. Effect of standards on new equipment design by new international standards and industry restraints

    NASA Astrophysics Data System (ADS)

    Endelman, Lincoln L.

    1991-01-01

    The use of international standards to further trade is one of the objectives of creating a standard. By having form fit and function compatible the free interchange of manufactured goods can be handled without hindrance. Unfortunately by setting up standards that are peculiar to a particular country or district it is possible to exclude competition from a group of manufacturers. A major effort is now underway to develop international laser standards. In the May I 990 issue of Laser Focus World Donald R. Johnson the director of industrial technology services for the National Institute of Standards and Technology (NIST formerly the National Bureau of Standards) is quoted as follows: " The common means of protectionism has been through certification for the market place. " The article goes on to say " Mr. Johnson expects this tradition to continue and that the new European Community (EC) will demand not just safety standards but performance standards as well. . . . the American laser industry must move very quickly on this issue or risk being left behind the European standards bandwagon. " The article continues laser companies must get involved in the actual standards negotiating process if they are to have a say in future policy. A single set of standards would reduce the need to repeatedly recalibrate products for different national markets. " As a member of ISO TC-72 SC9 I am

  13. International Safety Regulation and Standards for Space Travel and Commerce

    NASA Astrophysics Data System (ADS)

    Pelton, J. N.; Jakhu, R.

    The evolution of air travel has led to the adoption of the 1944 Chicago Convention that created the International Civil Aviation Organization (ICAO), headquartered in Montreal, Canada, and the propagation of aviation safety standards. Today, ICAO standardizes and harmonizes commercial air safety worldwide. Space travel and space safety are still at an early stage of development, and the adoption of international space safety standards and regulation still remains largely at the national level. This paper explores the international treaties and conventions that govern space travel, applications and exploration today and analyzes current efforts to create space safety standards and regulations at the national, regional and global level. Recent efforts to create a commercial space travel industry and to license commercial space ports are foreseen as means to hasten a space safety regulatory process.

  14. HVI Ballistic Performance Characterization of Non-Parallel Walls

    NASA Technical Reports Server (NTRS)

    Bohl, William; Miller, Joshua; Christiansen, Eric

    2012-01-01

    The Double-Wall, "Whipple" Shield [1] has been the subject of many hypervelocity impact studies and has proven to be an effective shield system for Micro-Meteoroid and Orbital Debris (MMOD) impacts for spacecraft. The US modules of the International Space Station (ISS), with their "bumper shields" offset from their pressure holding rear walls provide good examples of effective on-orbit use of the double wall shield. The concentric cylinder shield configuration with its large radius of curvature relative to separation distance is easily and effectively represented for testing and analysis as a system of two parallel plates. The parallel plate double wall configuration has been heavily tested and characterized for shield performance for normal and oblique impacts for the ISS and other programs. The double wall shield and principally similar Stuffed Whipple Shield are very common shield types for MMOD protection. However, in some locations with many spacecraft designs, the rear wall cannot be modeled as being parallel or concentric with the outer bumper wall. As represented in Figure 1, there is an included angle between the two walls. And, with a cylindrical outer wall, the effective included angle constantly changes. This complicates assessment of critical spacecraft components located within outer spacecraft walls when using software tools such as NASA's BumperII. In addition, the validity of the risk assessment comes into question when using the standard double wall shield equations, especially since verification testing of every set of double wall included angles is impossible.

  15. The Specific Nature of Plant Cell Wall Polysaccharides 1

    PubMed Central

    Nevins, Donald J.; English, Patricia D.; Albersheim, Peter

    1967-01-01

    Polysaccharide compositions of cell walls were assessed by quantitative analyses of the component sugars. Cell walls were hydrolyzed in 2 n trifluoroacetic acid and the liberated sugars reduced to their respective alditols. The alditols were acetylated and the resulting alditol acetates separated by gas chromatography. Quantitative assay of the alditol acetates was accomplished by electronically integrating the detector output of the gas chromatograph. Myo-inositol, introduced into the sample prior to hydrolysis, served as an internal standard. The cell wall polysaccharide compositions of plant varieties within a given species are essentially identical. However, differences in the sugar composition were observed in cell walls prepared from different species of the same as well as of different genera. The fact that the wall compositions of different varieties of the same species are the same indicates that the biosynthesis of cell wall polysaccharides is genetically regulated. The cell walls of various morphological parts (roots, hypocotyls, first internodes and primary leaves) of bean plants were each found to have a characteristic sugar composition. It was found that the cell wall sugar composition of suspension-cultured sycamore cells could be altered by growing the cells on different carbon sources. This demonstrates that the biosynthesis of cell wall polysaccharides can be manipulated without fatal consequences. PMID:16656594

  16. 5. 'Stones for Wing Walls, Tunnel Walls, BeltCourse and Coping,' ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. 'Stones for Wing Walls, Tunnel Walls, Belt-Course and Coping,' Southern Pacific Standard Plan Tunnels, ca. 1909. - Central Pacific Transcontinental Railroad, Sacramento to Nevada state line, Sacramento, Sacramento County, CA

  17. Fifth International Standard for Gas-Gangrene Antitoxin (Perfringens) (Clostridium welchii Type A Antitoxin)

    PubMed Central

    Evans, D. G.; Perkins, F. T.

    1963-01-01

    The Fifth International Standard Gas-Gangrene Antitoxin (Perfringens) (Clostridium welchii Type A Antitoxin) was prepared from serum from immunized horses. It was freeze-dried in ampoules each containing 1 ml. Seven laboratories collaborated in assaying its potency in terms of the Fourth International Standard by the intravenous inoculation of mice. The geometric mean value, taking the results of all the laboratories, was 270 International Units per ampoule and the maximum variation between laboratories was 15%. In vitro (lecithinase) tests were also done by three laboratories, giving an average of 261 International Units per ampoule. The dry weight contents of ampoules, determined in three laboratories, varied by less than 3%, with an average of 90.35 mg per ampoule. The standard was stable for 120 hours at 56°C. Each ampoule of the Fifth International Standard for Gas-Gangrene Antitoxin (Perfringens) contains 270 International Units, and one International Unit is contained in 0.3346 mg of the International Standard. PMID:14107745

  18. The CMMI Product Suite and International Standards

    DTIC Science & Technology

    2006-07-01

    standards: “2.3 Reference Documents 2.3.1 Applicable ISO /IEC documents, including ISO /IEC 12207 and ISO /IEC 15504.” “3.1 Development User Requirements...related international standards such as ISO 9001:2000, 12207 , 15288 © 2006 by Carnegie Mellon University Page 12 Key Supplements Needed...the Measurement Framework in ISO /IEC 15504; and • the Process Reference Model included in ISO /IEC 12207 . A possible approach has been developed for

  19. Multilevel Linkages between State Standards, Teacher Standards, and Student Achievement: Testing External versus Internal Standards-Based Education Models

    ERIC Educational Resources Information Center

    Lee, Jaekyung; Liu, Xiaoyan; Amo, Laura Casey; Wang, Weichun Leilani

    2014-01-01

    Drawing on national and state assessment datasets in reading and math, this study tested "external" versus "internal" standards-based education models. The goal was to understand whether and how student performance standards work in multilayered school systems under No Child Left Behind Act of 2001 (NCLB). Under the…

  20. [Differences and international standardization between acupuncture as therapy and as specialty].

    PubMed

    Ng, Szetuen

    2017-01-12

    The purpose of this study is to explore the differences of definition and clinical roles as well as international standardization between acupuncture as therapy and as specialty, which can provide reference evidence for specialization and internationalization of acupuncture. Owing to the clinical efficacy and safety, the credibility and controversy both exist in acupuncture; moreover, there is a lack of fair definition and international precedent regarding acupuncture specialty. Therefore, it is particularly essential to objectively compare the differences of definitions and clinical roles as well as criteria of international standardization for acupuncture as therapy and as specialty. It is believed acupuncture standardization can draw lessons from the international medical standards, evidence-based medicine and acupuncture theory from the following three major projects:acupuncture safety and contraindications; acupuncture indications and treatment guidelines; acupuncture indication classified into 3 levels of evidence-based acupuncture disease spectrum, as objective evidence of indication of acupuncture specialty.

  1. Halogenation of microcapsule walls

    NASA Technical Reports Server (NTRS)

    Davis, T. R.; Schaab, C. K.; Scott, J. C.

    1972-01-01

    Procedure for halogenation of confining walls of both gelatin and gelatin-phenolic resin capsules is similar to that used for microencapsulation. Ten percent halogen content renders capsule wall nonburning; any higher content enhances flame-retardant properties of selected internal phase material. Halogenation decreases permeability of wall material to encapsulated materials.

  2. International standards for brucellosis prevention and management.

    PubMed

    Ragan, V; Vroegindewey, G; Babcock, S

    2013-04-01

    International standards are a crucial element in brucellosis prevention and management. They allow policy-makers, scientists, epidemiologists, laboratories and trade entities to have a common vocabulary for communication and understanding of the disease. These standards cover the entire spectrum of activities from surveillance, testing, prophylaxis, transport and trade to policy development, research and reporting. Developing, adhering to and monitoring standards increases both the effectiveness and efficiency of prevention and management programmes. Creating standards with the input of all stakeholders ensures that the standards do not adversely affect the requirements of any of the multiple parties involved. The World Organisation for Animal Health (OIE), in conjunction with its Member Countries, and through its standing and ad hoc committees plus expert input, has taken a key leadership role in developing and reviewing brucellosis standards. These standards are used to harmonise testing, prevention processes, vaccines and reporting, to support trade and to protect human and animal health.

  3. 77 FR 60625 - Minimum Internal Control Standards for Class II Gaming

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-04

    ...-37 Minimum Internal Control Standards for Class II Gaming AGENCY: National Indian Gaming Commission... Internal Control Standards that were published on September 21, 2012. DATES: The effective date [email protected] . FOR FURTHER INFORMATION CONTACT: Jennifer Ward, Attorney, NIGC Office of General Counsel, at...

  4. CTEPP STANDARD OPERATING PROCEDURE FOR PREPARATION OF SURROGATE RECOVERY STANDARD AND INTERNAL STANDARD SOLUTIONS FOR POLAR TARGET ANALYTES (SOP-5.26)

    EPA Science Inventory

    This SOP describes the method used for preparing surrogate recovery standard and internal standard solutions for the analysis of polar target analytes. It also describes the method for preparing calibration standard solutions for polar analytes used for gas chromatography/mass sp...

  5. Heat Conductivity Resistance of Concrete Wall Panel by Water Flowing in Different Orientations of Internal PVC pipe

    NASA Astrophysics Data System (ADS)

    Umi, N. N.; Norazman, M. N.; Daud, N. M.; Yusof, M. A.; Yahya, M. A.; Othman, M.

    2018-04-01

    Green building technology and sustainability development is current focus in the world nowadays. In Malaysia and most tropical countries the maximum temperature recorded typically at 35°C. Air-conditioning system has become a necessity in occupied buildings, thereby increasing the cost of electric consumption. The aim of this study is to find out the solution in minimizing heat transfer from the external environment and intentions towards going green. In this study, the experimental work includes testing three types of concrete wall panels. The main heat intervention material in this research is 2 inch diameter Polyvinyl Chloride (PVC) pipe embedded at the center of the concrete wall panel, while the EPS foam beads were added to the cement content in the concrete mix forming the outer layer of the wall panel. Water from the rainwater harvesting system is regulated in the PVC pipe to intervene with the heat conductivity through the wall panel. Results from the experimental works show that the internal surface temperature of these heat resistance wall panels is to 3□C lower than control wall panel from plain interlocking bricks.

  6. International standards for pandemic screening using infrared thermography

    NASA Astrophysics Data System (ADS)

    Pascoe, D. D.; Ring, E. F.; Mercer, J. B.; Snell, J.; Osborn, D.; Hedley-Whyte, J.

    2010-03-01

    The threat of a virulent strain of influenza, severe acute respiratory syndrome (SARS), tuberculosis, H1N1/A virus (swine flu) and possible mutations are a constant threat to global health. Implementation of pandemic infrared thermographic screening is based on the detection of febrile temperatures (inner canthus of the eyes) that are correlated with an infectious disease. Previous attempts at pandemic thermal screening have experienced problems (e.g. SARS outbreak, Singapore 2003) associated with the deployment plan, implementation and operation of the screening thermograph. Since this outbreak, the International Electrotechnical Commission has developed international standards that set minimum requirements for thermographic system fever screening and procedures that insure reliable and reproducible measurements. These requirements are published in IEC 80601-2-59:2008, Medical electrical equipment - Part 2-59: Particular requirements for the basic safety and essential performance of screening thermographs for human febrile temperature screening. The International Organization for Standardization has developed ISO/TR 13154:2009, Medical Electrical Equipment - which provides deployment, implementation and operational guidelines for identifying febrile humans using a screening thermograph. These new standards includes recommendations for camera calibrations, use of black body radiators, view field, focus, pixels within measurement site, image positioning, and deployment locations. Many current uses of thermographic screening at airports do not take into account critical issues addressed in the new standard, and are operating below the necessary effectiveness and efficiency. These documents, related thermal research, implications for epidemiology screening, and the future impact on medical thermography are discussed.

  7. International collaborative study for the calibration of proposed International Standards for thromboplastin, rabbit, plain, and for thromboplastin, recombinant, human, plain.

    PubMed

    van den Besselaar, A M H P; Chantarangkul, V; Angeloni, F; Binder, N B; Byrne, M; Dauer, R; Gudmundsdottir, B R; Jespersen, J; Kitchen, S; Legnani, C; Lindahl, T L; Manning, R A; Martinuzzo, M; Panes, O; Pengo, V; Riddell, A; Subramanian, S; Szederjesi, A; Tantanate, C; Herbel, P; Tripodi, A

    2018-01-01

    Essentials Two candidate International Standards for thromboplastin (coded RBT/16 and rTF/16) are proposed. International Sensitivity Index (ISI) of proposed standards was assessed in a 20-centre study. The mean ISI for RBT/16 was 1.21 with a between-centre coefficient of variation of 4.6%. The mean ISI for rTF/16 was 1.11 with a between-centre coefficient of variation of 5.7%. Background The availability of International Standards for thromboplastin is essential for the calibration of routine reagents and hence the calculation of the International Normalized Ratio (INR). Stocks of the current Fourth International Standards are running low. Candidate replacement materials have been prepared. This article describes the calibration of the proposed Fifth International Standards for thromboplastin, rabbit, plain (coded RBT/16) and for thromboplastin, recombinant, human, plain (coded rTF/16). Methods An international collaborative study was carried out for the assignment of International Sensitivity Indexes (ISIs) to the candidate materials, according to the World Health Organization (WHO) guidelines for thromboplastins and plasma used to control oral anticoagulant therapy with vitamin K antagonists. Results Results were obtained from 20 laboratories. In several cases, deviations from the ISI calibration model were observed, but the average INR deviation attributabled to the model was not greater than 10%. Only valid ISI assessments were used to calculate the mean ISI for each candidate. The mean ISI for RBT/16 was 1.21 (between-laboratory coefficient of variation [CV]: 4.6%), and the mean ISI for rTF/16 was 1.11 (between-laboratory CV: 5.7%). Conclusions The between-laboratory variation of the ISI for candidate material RBT/16 was similar to that of the Fourth International Standard (RBT/05), and the between-laboratory variation of the ISI for candidate material rTF/16 was slightly higher than that of the Fourth International Standard (rTF/09). The candidate materials

  8. The Fluid Mechanics of a Wavy-Wall Bioreactor

    NASA Astrophysics Data System (ADS)

    Sucosky, Philippe; Bilgen, Bahar; Aleem, Alexander; Neitzel, Paul; Barabino, Gilda

    2004-11-01

    Bioreactors are devices used for the production of mammalian tissue in vitro. Although mixing has been shown to stimulate the growth of cartilage constructs, high shear-stress levels can damage the cells. In order to enhance mixing while minimizing shear, a wavy-wall bioreactor (WWB) featuring a sinusoidal internal profile has been designed. The turbulent hydrodynamic environment produced in this device is investigated experimentally using particle-image velocimetry. A model bioreactor made of acrylic and filled with an index-matching solution of zinc iodide is used to compensate for the refraction of light at the walls. The flow observed in different planes is shown to be periodic, spatially dependent, and dominated by mean-shear rather than Reynolds stresses in the vicinity of constructs. Finally, a comparison between the mean-shear stresses obtained in the WWB and in a standard spinner flask reveals similar stress levels near the construct walls.

  9. Wall characterization for through-the-wall radar applications

    NASA Astrophysics Data System (ADS)

    Greneker, Gene; Rausch, E. O.

    2008-04-01

    There has been continuing interest in the penetration of multilayer building materials, such as wood walls with air gaps and concrete hollow core block, using through-the-wall (TTW) radar systems. TTW operational techniques and signal propagation paths vary depending on how the TTW system is intended to be operated. For example, the operator of a TTW radar may be required to place the radar against the intervening wall of interest while collecting data. Other operational doctrines allow the radar to be operated in a stand-off mode from the wall. The stand-off distances can vary from feet to hundreds of feet, depending on the type of radar being used. When a signal is propagated through a multilayer wall with air gaps between the material and the wall construction uses materials of radically different dielectric constants, attenuation may not be the only effect that the probing signal experiences passing through the wall. This paper presents measurements of a hollow core concrete block wall and the measurement of a standard wall constructed of siding and wallboard. Both types of walls are typically found in most U.S. homes. These limited measurements demonstrate that the type of wall being penetrated by a wideband signal can modify the probing signal.

  10. 25 CFR 543.8 - What are the minimum internal control standards for bingo?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for bingo? 543.8 Section 543.8 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.8 What are the minimum internal control standards for bingo? (a) Supervision....

  11. 25 CFR 543.8 - What are the minimum internal control standards for bingo?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for bingo? 543.8 Section 543.8 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.8 What are the minimum internal control standards for bingo? (a) Supervision....

  12. 77 FR 37361 - National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-21

    ... National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion Engines; New Source Performance Standards for Stationary Internal Combustion Engines AGENCY: Environmental Protection... Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion Engines; New Source Performance...

  13. International standards for monoclonal antibodies to support pre- and post-marketing product consistency: Evaluation of a candidate international standard for the bioactivities of rituximab.

    PubMed

    Prior, Sandra; Hufton, Simon E; Fox, Bernard; Dougall, Thomas; Rigsby, Peter; Bristow, Adrian

    2018-01-01

    The intrinsic complexity and heterogeneity of therapeutic monoclonal antibodies is built into the biosimilarity paradigm where critical quality attributes are controlled in exhaustive comparability studies with the reference medicinal product. The long-term success of biosimilars will depend on reassuring healthcare professionals and patients of consistent product quality, safety and efficacy. With this aim, the World Health Organization has endorsed the need for public bioactivity standards for therapeutic monoclonal antibodies in support of current controls. We have developed a candidate international potency standard for rituximab that was evaluated in a multi-center collaborative study using participants' own qualified Fc-effector function and cell-based binding bioassays. Dose-response curve model parameters were shown to reflect similar behavior amongst rituximab preparations, albeit with some differences in potency. In the absence of a common reference standard, potency estimates were in poor agreement amongst laboratories, but the use of the candidate preparation significantly reduced this variability. Our results suggest that the candidate rituximab standard can support bioassay performance and improve data harmonization, which when implemented will promote consistency of rituximab products over their life-cycles. This data provides the first scientific evidence that a classical standardization exercise allowing traceability of bioassay data to an international standard is also applicable to rituximab. However, we submit that this new type of international standard needs to be used appropriately and its role not to be mistaken with that of the reference medicinal product.

  14. International standards for monoclonal antibodies to support pre- and post-marketing product consistency: Evaluation of a candidate international standard for the bioactivities of rituximab

    PubMed Central

    Prior, Sandra; Hufton, Simon E.; Dougall, Thomas; Rigsby, Peter; Bristow, Adrian

    2018-01-01

    ABSTRACT The intrinsic complexity and heterogeneity of therapeutic monoclonal antibodies is built into the biosimilarity paradigm where critical quality attributes are controlled in exhaustive comparability studies with the reference medicinal product. The long-term success of biosimilars will depend on reassuring healthcare professionals and patients of consistent product quality, safety and efficacy. With this aim, the World Health Organization has endorsed the need for public bioactivity standards for therapeutic monoclonal antibodies in support of current controls. We have developed a candidate international potency standard for rituximab that was evaluated in a multi-center collaborative study using participants' own qualified Fc-effector function and cell-based binding bioassays. Dose-response curve model parameters were shown to reflect similar behavior amongst rituximab preparations, albeit with some differences in potency. In the absence of a common reference standard, potency estimates were in poor agreement amongst laboratories, but the use of the candidate preparation significantly reduced this variability. Our results suggest that the candidate rituximab standard can support bioassay performance and improve data harmonization, which when implemented will promote consistency of rituximab products over their life-cycles. This data provides the first scientific evidence that a classical standardization exercise allowing traceability of bioassay data to an international standard is also applicable to rituximab. However, we submit that this new type of international standard needs to be used appropriately and its role not to be mistaken with that of the reference medicinal product. PMID:28985159

  15. 78 FR 37505 - International Standard-Setting Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-21

    ... Code of Practice for Weed Control to Prevent and Reduce Pyrrolizidine Alkaloid Contamination in Food... DEPARTMENT OF AGRICULTURE Food Safety and Inspection Service [Docket No. FSIS-2013-0002] International Standard-Setting Activities AGENCY: Office of Food Safety, USDA. ACTION: Notice. SUMMARY: This...

  16. 75 FR 31749 - International Standard-Setting Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-04

    ... DEPARTMENT OF AGRICULTURE Food Safety and Inspection Service [Docket No. FSIS-2009-0033] International Standard-Setting Activities AGENCY: Office of Food Safety, USDA. ACTION: Notice. SUMMARY: This..., and hand- or courier-delivered items: Send to Docket Clerk, U.S. Department of Agriculture, Food...

  17. Standardization and future directions in pattern identification research: International brainstorming session.

    PubMed

    Jung, Jeeyoun; Park, Bongki; Lee, Ju Ah; You, Sooseong; Alraek, Terje; Bian, Zhao-Xiang; Birch, Stephen; Kim, Tae-Hun; Xu, Hao; Zaslawski, Chris; Kang, Byoung-Kab; Lee, Myeong Soo

    2016-09-01

    An international brainstorming session on standardizing pattern identification (PI) was held at the Korea Institute of Oriental Medicine on October 1, 2013 in Daejeon, South Korea. This brainstorming session was convened to gather insights from international traditional East Asian medicine specialists regarding PI standardization. With eight presentations and discussion sessions, the meeting allowed participants to discuss research methods and diagnostic systems used in traditional medicine for PI. One speaker presented a talk titled "The diagnostic criteria for blood stasis syndrome: implications for standardization of PI". Four speakers presented on future strategies and objective measurement tools that could be used in PI research. Later, participants shared information and methodology for accurate diagnosis and PI. They also discussed the necessity for standardizing PI and methods for international collaborations in pattern research.

  18. Assessment of turbulent flow effects on the vessel wall using four-dimensional flow MRI.

    PubMed

    Ziegler, Magnus; Lantz, Jonas; Ebbers, Tino; Dyverfeldt, Petter

    2017-06-01

    To explore the use of MR-estimated turbulence quantities for the assessment of turbulent flow effects on the vessel wall. Numerical velocity data for two patient-derived models was obtained using computational fluid dynamics (CFD) for two physiological flow rates. The four-dimensional (4D) Flow MRI measurements were simulated at three different spatial resolutions and used to investigate the estimation of turbulent wall shear stress (tWSS) using the intravoxel standard deviation (IVSD) of velocity and turbulent kinetic energy (TKE) estimated near the vessel wall. Accurate estimation of tWSS using the IVSD is limited by the spatial resolution achievable with 4D Flow MRI. TKE, estimated near the wall, has a strong linear relationship to the tWSS (mean R 2  = 0.84). Near-wall TKE estimates from MR simulations have good agreement to CFD-derived ground truth (mean R 2  = 0.90). Maps of near-wall TKE have strong visual correspondence to tWSS. Near-wall estimation of TKE permits assessment of relative maps of tWSS, but direct estimation of tWSS is challenging due to limitations in spatial resolution. Assessment of tWSS and near-wall TKE may open new avenues for analysis of different pathologies. Magn Reson Med 77:2310-2319, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  19. Measurement of vascular wall attenuation: comparison of CT angiography using model-based iterative reconstruction with standard filtered back-projection algorithm CT in vitro.

    PubMed

    Suzuki, Shigeru; Machida, Haruhiko; Tanaka, Isao; Ueno, Eiko

    2012-11-01

    To compare the performance of model-based iterative reconstruction (MBIR) with that of standard filtered back projection (FBP) for measuring vascular wall attenuation. After subjecting 9 vascular models (actual attenuation value of wall, 89 HU) with wall thickness of 0.5, 1.0, or 1.5 mm that we filled with contrast material of 275, 396, or 542 HU to scanning using 64-detector computed tomography (CT), we reconstructed images using MBIR and FBP (Bone, Detail kernels) and measured wall attenuation at the center of the wall for each model. We performed attenuation measurements for each model and additional supportive measurements by a differentiation curve. We analyzed statistics using analyzes of variance with repeated measures. Using the Bone kernel, standard deviation of the measurement exceeded 30 HU in most conditions. In measurements at the wall center, the attenuation values obtained using MBIR were comparable to or significantly closer to the actual wall attenuation than those acquired using Detail kernel. Using differentiation curves, we could measure attenuation for models with walls of 1.0- or 1.5-mm thickness using MBIR but only those of 1.5-mm thickness using Detail kernel. We detected no significant differences among the attenuation values of the vascular walls of either thickness (MBIR, P=0.1606) or among the 3 densities of intravascular contrast material (MBIR, P=0.8185; Detail kernel, P=0.0802). Compared with FBP, MBIR reduces both reconstruction blur and image noise simultaneously, facilitates recognition of vascular wall boundaries, and can improve accuracy in measuring wall attenuation. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  20. Human Rights and Values Education: Using the International Standards.

    ERIC Educational Resources Information Center

    Reardon, Betty A.

    1994-01-01

    Asserts that, in teaching about human rights, the international standards should be the fundamental core of the content and values to be communicated. Recommends that teachers should use the Universal Declaration of Human Rights as the standard by which the actions of individuals and governments should be compared. (CFR)

  1. Thermal Conductivity of Single-Walled Carbon Nanotube with Internal Heat Source Studied by Molecular Dynamics Simulation

    NASA Astrophysics Data System (ADS)

    Li, Yuan-Wei; Cao, Bing-Yang

    2013-12-01

    The thermal conductivity of (5, 5) single-walled carbon nanotubes (SWNTs) with an internal heat source is investigated by using nonequilibrium molecular dynamics (NEMD) simulation incorporating uniform heat source and heat source-and-sink schemes. Compared with SWNTs without an internal heat source, i.e., by a fixed-temperature difference scheme, the thermal conductivity of SWNTs with an internal heat source is much lower, by as much as half in some cases, though it still increases with an increase of the tube length. Based on the theory of phonon dynamics, a function called the phonon free path distribution is defined to develop a simple one-dimensional heat conduction model considering an internal heat source, which can explain diffusive-ballistic heat transport in carbon nanotubes well.

  2. Performance of masonry enclosure walls: lessons learned from recent earthquakes

    NASA Astrophysics Data System (ADS)

    Vicente, Romeu Silva; Rodrigues, Hugo; Varum, Humberto; Costa, Aníbal; Mendes da Silva, José António Raimundo

    2012-03-01

    This paper discusses the issue of performance requirements and construction criteria for masonry enclosure and infill walls. Vertical building enclosures in European countries are very often constituted by non-load-bearing masonry walls, using horizontally perforated clay bricks. These walls are generally supported and confined by a reinforced concrete frame structure of columns and beams/slabs. Since these walls are commonly considered to be nonstructural elements and their influence on the structural response is ignored, their consideration in the design of structures as well as their connection to the adjacent structural elements is frequently negligent or insufficiently detailed. As a consequence, nonstructural elements, as for wall enclosures, are relatively sensitive to drift and acceleration demands when buildings are subjected to seismic actions. Many international standards and technical documents stress the need for design acceptability criteria for nonstructural elements, however they do not specifically indicate how to prevent collapse and severe cracking, and how to enhance the overall stability in the case of moderate to high seismic loading. Furthermore, a review of appropriate measures to improve enclosure wall performance and both in-plane and out-of-plane integrity under seismic actions is addressed.

  3. Standard methods for sampling freshwater fishes: Opportunities for international collaboration

    USGS Publications Warehouse

    Bonar, Scott A.; Mercado-Silva, Norman; Hubert, Wayne A.; Beard, Douglas; Dave, Göran; Kubečka, Jan; Graeb, Brian D. S.; Lester, Nigel P.; Porath, Mark T.; Winfield, Ian J.

    2017-01-01

    With publication of Standard Methods for Sampling North American Freshwater Fishes in 2009, the American Fisheries Society (AFS) recommended standard procedures for North America. To explore interest in standardizing at intercontinental scales, a symposium attended by international specialists in freshwater fish sampling was convened at the 145th Annual AFS Meeting in Portland, Oregon, in August 2015. Participants represented all continents except Australia and Antarctica and were employed by state and federal agencies, universities, nongovernmental organizations, and consulting businesses. Currently, standardization is practiced mostly in North America and Europe. Participants described how standardization has been important for management of long-term data sets, promoting fundamental scientific understanding, and assessing efficacy of large spatial scale management strategies. Academics indicated that standardization has been useful in fisheries education because time previously used to teach how sampling methods are developed is now more devoted to diagnosis and treatment of problem fish communities. Researchers reported that standardization allowed increased sample size for method validation and calibration. Group consensus was to retain continental standards where they currently exist but to further explore international and intercontinental standardization, specifically identifying where synergies and bridges exist, and identify means to collaborate with scientists where standardization is limited but interest and need occur.

  4. International Labour Standards. A Workers' Education Manual.

    ERIC Educational Resources Information Center

    International Labour Office, Geneva (Switzerland).

    Concerned with the standard-setting work of the International Labor Organization (ILO), this manual is chiefly intended to provide guidance for worker's education instructors and trade union officials. It contains nine chapters: (1) the ILO origins and history are traced and the structure is explained; (2 & 3) procedures for the origination…

  5. Summary Brief: International Baccalaureate Standards Development and Alignment Project

    ERIC Educational Resources Information Center

    Conley, David T.; Ward, Terri

    2009-01-01

    Although the International Baccalaureate (IB) Diploma Programme is offered by many high schools in the United States and considered to be challenging and rich in content, the curriculum has not been analyzed to determine its alignment with college readiness standards or state educational standards in the U.S. The research methodology employed by…

  6. AAALAC International Standards and Accreditation Process

    PubMed Central

    Gettayacamin, Montip; Retnam, Leslie

    2017-01-01

    AAALAC International is a private, nonprofit organization that promotes humane treatment of animals in science through a voluntary international accreditation program. AAALAC International accreditation is recognized around the world as a symbol of high quality animal care and use for research, teaching and testing, as well as promoting animal welfare. Animals owned by the institution that are used for research, teaching and testing are included as part of an accredited program. More than 990 animal care and use institutions in 42 countries around the world (more than 170 programs in 13 countries in the Pacific Rim region) have earned AAALAC International accreditation. The AAALAC International Council on Accreditation evaluates overall performance and all aspects of an animal care and use program, involving an in-depth, multilayered, confidential peer-review process. The evaluators (site visitors) consider compliance with applicable local animal legislation of the host country, institutional policies, and employ a customized approach for evaluating overall program performance using a series of primary standards that include the Guide for the Care and Use of Laboratory Animals, the Guide for the Care and Use of Agricultural Animals in Research and Teaching, or the European Convention for the Protection of Vertebrate Animals Used for Experimental and Other Purposes, Council of Europe (ETS 123), and supplemental Reference Resources, as applicable. PMID:28744349

  7. Standard addition with internal standardisation as an alternative to using stable isotope labelled internal standards to correct for matrix effects-Comparison and validation using liquid chromatography-​tandem mass spectrometric assay of vitamin D.

    PubMed

    Hewavitharana, Amitha K; Abu Kassim, Nur Sofiah; Shaw, Paul Nicholas

    2018-06-08

    With mass spectrometric detection in liquid chromatography, co-eluting impurities affect the analyte response due to ion suppression/enhancement. Internal standard calibration method, using co-eluting stable isotope labelled analogue of each analyte as the internal standard, is the most appropriate technique available to correct for these matrix effects. However, this technique is not without drawbacks, proved to be expensive because separate internal standard for each analyte is required, and the labelled compounds are expensive or require synthesising. Traditionally, standard addition method has been used to overcome the matrix effects in atomic spectroscopy and was a well-established method. This paper proposes the same for mass spectrometric detection, and demonstrates that the results are comparable to those with the internal standard method using labelled analogues, for vitamin D assay. As conventional standard addition procedure does not address procedural errors, we propose the inclusion of an additional internal standard (not co-eluting). Recoveries determined on human serum samples show that the proposed method of standard addition yields more accurate results than the internal standardisation using stable isotope labelled analogues. The precision of the proposed method of standard addition is superior to the conventional standard addition method. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Internal Standards: A Source of Analytical Bias For Volatile Organic Analyte Determinations

    EPA Science Inventory

    The use of internal standards in the determination of volatile organic compounds as described in SW-846 Method 8260C introduces a potential for bias in results once the internal standards (ISTDs) are added to a sample for analysis. The bias is relative to the dissimilarity betw...

  9. 25 CFR 542.14 - What are the minimum internal control standards for the cage?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for the cage? 542.14 Section 542.14 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.14 What are the minimum internal control standards for the cage? (a) Computer applications. For...

  10. 25 CFR 543.9 - What are the minimum internal control standards for pull tabs?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for pull tabs? 543.9 Section 543.9 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.9 What are the minimum internal control standards for pull tabs? (a)...

  11. 25 CFR 542.8 - What are the minimum internal control standards for pull tabs?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for pull tabs? 542.8 Section 542.8 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.8 What are the minimum internal control standards for pull tabs? (a) Computer applications. For...

  12. 25 CFR 543.9 - What are the minimum internal control standards for pull tabs?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for pull tabs? 543.9 Section 543.9 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.9 What are the minimum internal control standards for pull tabs? (a)...

  13. 25 CFR 542.8 - What are the minimum internal control standards for pull tabs?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for pull tabs? 542.8 Section 542.8 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.8 What are the minimum internal control standards for pull tabs? (a) Computer applications. For...

  14. 25 CFR 542.8 - What are the minimum internal control standards for pull tabs?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 25 Indians 2 2012-04-01 2012-04-01 false What are the minimum internal control standards for pull tabs? 542.8 Section 542.8 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.8 What are the minimum internal control standards for pull tabs? (a) Computer applications. For...

  15. 78 FR 54606 - National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-05

    ... Combustion Engines; New Source Performance Standards for Stationary Internal Combustion Engines AGENCY... hazardous air pollutants for stationary reciprocating internal combustion engines and the standards of performance for stationary internal combustion engines. Subsequently, the EPA received three petitions for...

  16. 25 CFR 542.42 - What are the minimum internal control standards for internal audit for Tier C gaming operations?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... reconciliation process; (ii) Pull tabs, including but not limited to, statistical records, winner verification... 25 Indians 2 2010-04-01 2010-04-01 false What are the minimum internal control standards for... COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.42 What are...

  17. 25 CFR 542.22 - What are the minimum internal control standards for internal audit for Tier A gaming operations?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... but not limited to, bingo card control, payout procedures, and cash reconciliation process; (ii) Pull... 25 Indians 2 2010-04-01 2010-04-01 false What are the minimum internal control standards for... COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.22 What are...

  18. 25 CFR 542.32 - What are the minimum internal control standards for internal audit for Tier B gaming operations?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... but not limited to, bingo card control, payout procedures, and cash reconciliation process; (ii) Pull... 25 Indians 2 2010-04-01 2010-04-01 false What are the minimum internal control standards for... COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.32 What are...

  19. International Micrographics Standards: Report of the 1979 Paris Meeting of ISO/TC171.

    ERIC Educational Resources Information Center

    Heynen, Jeffrey

    1980-01-01

    Describes a meeting of the technical committee on micrographics of the International Organization for Standardization, and fcuses on the committee's work relating to the reproduction of library materials within the general context of international standards-making activities. (FM)

  20. Inverse measurement of wall pressure field in flexible-wall wind tunnels using global wall deformation data

    NASA Astrophysics Data System (ADS)

    Brown, Kenneth; Brown, Julian; Patil, Mayuresh; Devenport, William

    2018-02-01

    The Kevlar-wall anechoic wind tunnel offers great value to the aeroacoustics research community, affording the capability to make simultaneous aeroacoustic and aerodynamic measurements. While the aeroacoustic potential of the Kevlar-wall test section is already being leveraged, the aerodynamic capability of these test sections is still to be fully realized. The flexibility of the Kevlar walls suggests the possibility that the internal test section flow may be characterized by precisely measuring small deflections of the flexible walls. Treating the Kevlar fabric walls as tensioned membranes with known pre-tension and material properties, an inverse stress problem arises where the pressure distribution over the wall is sought as a function of the measured wall deflection. Experimental wall deformations produced by the wind loading of an airfoil model are measured using digital image correlation and subsequently projected onto polynomial basis functions which have been formulated to mitigate the impact of measurement noise based on a finite-element study. Inserting analytic derivatives of the basis functions into the equilibrium relations for a membrane, full-field pressure distributions across the Kevlar walls are computed. These inversely calculated pressures, after being validated against an independent measurement technique, can then be integrated along the length of the test section to give the sectional lift of the airfoil. Notably, these first-time results are achieved with a non-contact technique and in an anechoic environment.

  1. Conducting wall Hall thrusters in magnetic shielding and standard configurations

    NASA Astrophysics Data System (ADS)

    Grimaud, Lou; Mazouffre, Stéphane

    2017-07-01

    Traditional Hall thrusters are fitted with boron nitride dielectric discharge channels that confine the plasma discharge. Wall properties have significant effects on the performances and stability of the thrusters. In magnetically shielded thrusters, interactions between the plasma and the walls are greatly reduced, and the potential drop responsible for ion acceleration is situated outside the channel. This opens the way to the utilization of alternative materials for the discharge channel. In this work, graphite walls are compared to BN-SiO2 walls in the 200 W magnetically shielded ISCT200-MS and the unshielded ISCT200-US Hall thrusters. The magnetically shielded thruster shows no significant change in the discharge current mean value and oscillations, while the unshielded thruster's discharge current increases by 25% and becomes noticeably less stable. The electric field profile is also investigated through laser spectroscopy, and no significant difference is recorded between the ceramic and graphite cases for the shielded thruster. The unshielded thruster, on the other hand, has its acceleration region shifted 15% of the channel length downstream. Lastly, the plume profile is measured with planar probes fitted with guard rings. Once again the material wall has little influence on the plume characteristics in the shielded thruster, while the unshielded one is significantly affected.

  2. Improving the efficiency of quantitative (1)H NMR: an innovative external standard-internal reference approach.

    PubMed

    Huang, Yande; Su, Bao-Ning; Ye, Qingmei; Palaniswamy, Venkatapuram A; Bolgar, Mark S; Raglione, Thomas V

    2014-01-01

    The classical internal standard quantitative NMR (qNMR) method determines the purity of an analyte by the determination of a solution containing the analyte and a standard. Therefore, the standard must meet the requirements of chemical compatibility and lack of resonance interference with the analyte as well as a known purity. The identification of such a standard can be time consuming and must be repeated for each analyte. In contrast, the external standard qNMR method utilizes a standard with a known purity to calibrate the NMR instrument. The external standard and the analyte are measured separately, thereby eliminating the matter of chemical compatibility and resonance interference between the standard and the analyte. However, the instrumental factors, including the quality of NMR tubes, must be kept the same. Any deviations will compromise the accuracy of the results. An innovative qNMR method reported herein utilizes an internal reference substance along with an external standard to assume the role of the standard used in the traditional internal standard qNMR method. In this new method, the internal reference substance must only be chemically compatible and be free of resonance-interference with the analyte or external standard whereas the external standard must only be of a known purity. The exact purity or concentration of the internal reference substance is not required as long as the same quantity is added to the external standard and the analyte. The new method reduces the burden of searching for an appropriate standard for each analyte significantly. Therefore the efficiency of the qNMR purity assay increases while the precision of the internal standard method is retained. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. [From manual workshop to international standard maker: exploration on production standard of acupuncture needle by Chengjiang acupuncture school].

    PubMed

    Cheng, Jie; Cao, Yang; Xia, Youbing

    2015-02-01

    ABSTRACT The exploration course on production standard of acupuncture needle by Chengjiang acupuncture school is reviewed in this paper. After new China was established, acupuncture needle standard was unified by Mr. CHENG Dan-an, which guided Suzhou Hua Erfang (predecessor of Suzhou Medical Supplies Factory) to make the quality standards and testing methods of acupuncture needle and improved the production process to make the modern acupuncture needle. Based on this, Suzhou Medical Supplies Factory followed the time development pace, ac tively introduced new technology, carried out technological innovation, and constantly improved the level of production technology, as a result, it gradually developed into one of the world's largest acupuncture needle production suppliers. Meanwhile, after establishing China's first national standard on acupuncture needle (GB 2024-1980), the Suzhou Medical Supplies Factory took the lead to draft "ISO) 17218:2014 the disposable use asepsis acupuncture needle", which was officially published as an international standard. The Suzhou Medical Supplies Factory developed from a manual workshop to an international standard maker.

  4. Selective Internal Heat Distribution in Modified Trombe Wall

    NASA Astrophysics Data System (ADS)

    Szyszka, Jerzy; Kogut, Janusz; Skrzypczak, Izabela; Kokoszka, Wanda

    2017-12-01

    At present, the requirements for thermal insulation of the external walls in buildings are being increased. There is a need to reduce energy consumption for heating rooms during the winter season. This may be achieved by increasing the thermal resistance of the outer partitions, using solutions that utilize either recuperation or solar radiation. The most popular systems include either solar collectors, or heat pump links or ground exchangers. Trombe walls (TW) are a very promising passive heating system, which requires little or no effort to operate, and may be very convenient in different climate conditions. A typical TW consists of a masonry wall painted a dark, heat absorbing paint colour and faced with a single or double layer of glass. The principle of operation is based on the photothermal conversion of solar radiation. There are various modifications of TW. They may improve the energy efficiency in relation to the climate conditions in which they operate. The hybrid solutions are also known. The efficiency of walls is related to the use of proper materials. In TW, the compromise should be sought between the thermal resistance and the ability to distribute heat from the absorbed energy of solar radiation. The paper presents an overview of the most commonly used solutions and discusses its own concept dedicated to the climate conditions of Central Europe.

  5. Adaptations of International Standards on Educational Leadership Preparation in Egypt

    ERIC Educational Resources Information Center

    Purinton, Ted; Khalil, Dalia

    2016-01-01

    This paper is a case study of one leadership preparation program, utilizing US school leadership standards and practices, offered in Egypt. This case study illuminates how cultural and policy distinctions impact differing necessities of educational leadership, and how those necessities conflict or concur with the international standards and…

  6. 25 CFR 543.17 - What are the minimum internal control standards for drop and count?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for drop and count? 543.17 Section 543.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.17 What are the minimum internal control standards for drop and count?...

  7. 25 CFR 543.15 - What are the minimum internal control standards for lines of credit?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for lines of credit? 543.15 Section 543.15 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.15 What are the minimum internal control standards for lines of credi...

  8. 25 CFR 543.15 - What are the minimum internal control standards for lines of credit?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for lines of credit? 543.15 Section 543.15 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.15 What are the minimum internal control standards for lines of credi...

  9. 25 CFR 543.17 - What are the minimum internal control standards for drop and count?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for drop and count? 543.17 Section 543.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.17 What are the minimum internal control standards for drop and count?...

  10. A Metadata Standard for Hydroinformatic Data Conforming to International Standards

    NASA Astrophysics Data System (ADS)

    Notay, Vikram; Carstens, Georg; Lehfeldt, Rainer

    2017-04-01

    The affordable availability of computing power and digital storage has been a boon for the scientific community. The hydroinformatics community has also benefitted from the so-called digital revolution, which has enabled the tackling of more and more complex physical phenomena using hydroinformatic models, instruments, sensors, etc. With models getting more and more complex, computational domains getting larger and the resolution of computational grids and measurement data getting finer, a large amount of data is generated and consumed in any hydroinformatics related project. The ubiquitous availability of internet also contributes to this phenomenon with data being collected through sensor networks connected to telecommunications networks and the internet long before the term Internet of Things existed. Although generally good, this exponential increase in the number of available datasets gives rise to the need to describe this data in a standardised way to not only be able to get a quick overview about the data but to also facilitate interoperability of data from different sources. The Federal Waterways Engineering and Research Institute (BAW) is a federal authority of the German Federal Ministry of Transport and Digital Infrastructure. BAW acts as a consultant for the safe and efficient operation of the German waterways. As part of its consultation role, BAW operates a number of physical and numerical models for sections of inland and marine waterways. In order to uniformly describe the data produced and consumed by these models throughout BAW and to ensure interoperability with other federal and state institutes on the one hand and with EU countries on the other, a metadata profile for hydroinformatic data has been developed at BAW. The metadata profile is composed in its entirety using the ISO 19115 international standard for metadata related to geographic information. Due to the widespread use of the ISO 19115 standard in the existing geodata infrastructure

  11. Determinants of Effective Information Transfer in International Regulatory Standards Adoption

    ERIC Educational Resources Information Center

    Popescu, Denisa

    2010-01-01

    The role of international regulatory standards within the current global environment has become of the most importance. The age of the global system and free market capitalism carried us into the unprecedented age of regulations, and standard setting. Regulations are now becoming the emerging mode of global governance. This study focuses on…

  12. Restructuring of international council for standardization in haematology (ICSH) in Asia.

    PubMed

    Tatsumi, N; Lewis, S M

    2002-08-01

    Standardization and harmonization in Laboratory testing are a key issue in the midst of globalization era, because most of laboratory testing has been currently achieved with various kinds of automated systems. In the developed countries, automated systems with highly-regulated principles are commonly used in the routine laboratory. However, there are so many undeveloped and developing countries in Asia that diversity of testing levels can be observed in the area. Some laboratories use glass chamber method for blood cell counting, while other laboratory use semi-automated or fully automated analyzers for complete blood count. International standardization on Hematology is focused on the developed system but not for the developing system. Established standardized documents therefore whould not be unsuitable for Asian societies. In the context, International Council for Standardization in Hematology (ICSH) changed its rules to adjust our Asian Societies and ICSH started to restructure the body. International ICSH society is divided into 5 region sub-groups. Asian area is able to possess one new sub-society, ICSH-Asia. Its reconstruction work has been just started with Asain colleagues, and we are now extending the new societies to discuss Asian problems on the quality of hematology testing.

  13. What States Should Know about International Standards in Science: Highlights from Achieve's Analysis

    ERIC Educational Resources Information Center

    Achieve, Inc., 2010

    2010-01-01

    Achieve, through support from the Noyce Foundation, examined ten sets of international standards with the intent of informing the development of both the conceptual framework and Next Generation Science Standards. Achieve selected countries based on their strong performance on international assessments and/or their economic, political, or cultural…

  14. Application of water flowing PVC pipe and EPS foam bead as insulation for wall panel

    NASA Astrophysics Data System (ADS)

    Ali, Umi Nadiah; Nor, Norazman Mohamad; Yusuf, Mohammed Alias; Othman, Maidiana; Yahya, Muhamad Azani

    2018-02-01

    Malaysia located in tropical climate which have a typical temperature range between 21 °C to 36 °C. Due to this, air-conditioning system for buildings become a necessity to provide comfort to occupants. In order to reduce the energy consumption of the air-conditioning system, the transmission of heat from outdoor to indoor space should be kept as minimum as possible. This article discuss about a technology to resist heat transfer through concrete wall panel using a hybrid method. In this research, PVC pipe was embedded at the center of concrete wall panel while the EPS foam beads were added about 1% of the cement content in the concrete mix forming the outer layer of the wall panel. Water is regulated in the PVC pipe from the rainwater harvesting system. The aim of this study is to minimize heat transfer from the external environment into the building. Internal building temperature which indicated in BS EN ISO 7730 or ASHRAE Standard 55 where the comfort indoor thermal is below 25°C during the daytime. Study observed that the internal surface temperature of heat resistance wall panel is up to 3°C lower than control wall panel. Therefore, we can conclude that application of heat resistance wall panel can lead to lower interior building temperature.

  15. 76 FR 62714 - Lifesaving Equipment: Production Testing and Harmonization With International Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-11

    ... apply to: prototypes (new designs) submitted after January 1, 2012; production testing of designs... Lifesaving Equipment: Production Testing and Harmonization With International Standards AGENCY: Coast Guard... and Standards Directorate, Office of Design and Engineering Standards, Lifesaving and Fire Safety...

  16. International standards for optical wireless communications: state-of-the-art and future directions

    NASA Astrophysics Data System (ADS)

    Marciniak, Marian

    2017-10-01

    As the number of active OWC installations is growing fast, the standards for compatibility of co-existing neighbouring systems are being developed. The paper addresses the Laser Safety (IEC standards), ITU-T Study Group 15 standards (G.640 Co-location longitudinally compatible interfaces for free space optical systems), ITU-Radiocommunication Sector standards (P.1817-1 Propagation data required for the design of terrestrial free-space optical links), and the IEEE Work in Progress - standardization activity on Visible Light Communications. International standards of FSO communications have been reviewed and discussed. ITU, IEC, and IEEE International standards for Free-Space Optical links have been reviewed. The system reliability and availability as well as security issues will be addressed as well in the talk.

  17. ISO 639-1 and ISO 639-2: International Standards for Language Codes. ISO 15924: International Standard for Names of Scripts.

    ERIC Educational Resources Information Center

    Byrum, John D.

    This paper describes two international standards for the representation of the names of languages. The first (ISO 639-1), published in 1988, provides two-letter codes for 136 languages and was produced primarily to meet terminological needs. The second (ISO 639-2) appeared in late 1998 and includes three-letter codes for 460 languages. This list…

  18. INTERNATIONAL STANDARDS ON FOOD AND ENVIRONMENTAL RADIOACTIVITY MEASUREMENT FOR RADIOLOGICAL PROTECTION: STATUS AND PERSPECTIVES.

    PubMed

    Calmet, D; Ameon, R; Bombard, A; Brun, S; Byrde, F; Chen, J; Duda, J-M; Forte, M; Fournier, M; Fronka, A; Haug, T; Herranz, M; Husain, A; Jerome, S; Jiranek, M; Judge, S; Kim, S B; Kwakman, P; Loyen, J; LLaurado, M; Michel, R; Porterfield, D; Ratsirahonana, A; Richards, A; Rovenska, K; Sanada, T; Schuler, C; Thomas, L; Tokonami, S; Tsapalov, A; Yamada, T

    2017-04-01

    Radiological protection is a matter of concern for members of the public and thus national authorities are more likely to trust the quality of radioactivity data provided by accredited laboratories using common standards. Normative approach based on international standards aims to ensure the accuracy or validity of the test result through calibrations and measurements traceable to the International System of Units. This approach guarantees that radioactivity test results on the same types of samples are comparable over time and space as well as between different testing laboratories. Today, testing laboratories involved in radioactivity measurement have a set of more than 150 international standards to help them perform their work. Most of them are published by the International Standardization Organization (ISO) and the International Electrotechnical Commission (IEC). This paper reviews the most essential ISO standards that give guidance to testing laboratories at different stages from sampling planning to the transmission of the test report to their customers, summarizes recent activities and achievements and present the perspectives on new standards under development by the ISO Working Groups dealing with radioactivity measurement in connection with radiological protection. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Chapter 23: International Standard reagents for harmonization of HPV serology and DNA assays--an update.

    PubMed

    Pagliusi, Sonia R; Dillner, Joakim; Pawlita, Michael; Quint, Wim G V; Wheeler, Cosette M; Ferguson, M

    2006-08-31

    International reference materials such as International Standard reagents facilitate quality assurance of essential biopharmaceutical products and related in vitro diagnostic tests. Standardization of antibody and DNA measurements and harmonization of laboratory procedures are key to the success of cancer prevention strategies through screening methods as well as for development and implementation of vaccination against the human papillomavirus (HPV). The WHO supported the preparation and initial analysis of a panel of candidate serological and DNA reference reagents aimed at facilitating inter-laboratory comparisons and detection of HPV worldwide. Two international collaborative studies assessed the performance of various HPV antibody and HPV-DNA detection assays and examined the feasibility of generating HPV antibody and DNA standard reagents. These studies showed that improvement in performance and comparability of assays is urgently needed and that the use of the same International Standard reference reagent could significantly improve performance and comparability. It is hoped that the establishment of International Units and International Standards for HPV antibody and DNA analysis will be pursued with high priority.

  20. Software database creature for investment property measurement according to international standards

    NASA Astrophysics Data System (ADS)

    Ponomareva, S. V.; Merzliakova, N. A.

    2018-05-01

    The article deals with investment property measurement and accounting problems at the international, national and enterprise levels. The need to create the software for investment property measurement according to International Accounting Standards was substantiated. The necessary software functions and the processes were described.

  1. Wall shear stress in intracranial aneurysms and adjacent arteries☆

    PubMed Central

    Wang, Fuyu; Xu, Bainan; Sun, Zhenghui; Wu, Chen; Zhang, Xiaojun

    2013-01-01

    Hemodynamic parameters play an important role in aneurysm formation and growth. However, it is difficult to directly observe a rapidly growing de novo aneurysm in a patient. To investigate possible associations between hemodynamic parameters and the formation and growth of intracranial aneurysms, the present study constructed a computational model of a case with an internal carotid artery aneurysm and an anterior communicating artery aneurysm, based on the CT angiography findings of a patient. To simulate the formation of the anterior communicating artery aneurysm and the growth of the internal carotid artery aneurysm, we then constructed a model that virtually removed the anterior communicating artery aneurysm, and a further two models that also progressively decreased the size of the internal carotid artery aneurysm. Computational simulations of the fluid dynamics of the four models were performed under pulsatile flow conditions, and wall shear stress was compared among the different models. In the three aneurysm growth models, increasing size of the aneurysm was associated with an increased area of low wall shear stress, a significant decrease in wall shear stress at the dome of the aneurysm, and a significant change in the wall shear stress of the parent artery. The wall shear stress of the anterior communicating artery remained low, and was significantly lower than the wall shear stress at the bifurcation of the internal carotid artery or the bifurcation of the middle cerebral artery. After formation of the anterior communicating artery aneurysm, the wall shear stress at the dome of the internal carotid artery aneurysm increased significantly, and the wall shear stress in the upstream arteries also changed significantly. These findings indicate that low wall shear stress may be associated with the initiation and growth of aneurysms, and that aneurysm formation and growth may influence hemodynamic parameters in the local and adjacent arteries. PMID:25206394

  2. Fabrication of cylindrical superhydrophobic microchannels by replicating lotus leaf structures on internal walls

    NASA Astrophysics Data System (ADS)

    Das, Ajit; Bhaumik, Soubhik Kumar

    2018-04-01

    Cylindrical superhydrophobic microchannels are fabricated by replicating lotus leaf structures on internal walls. The fabrication process comprises of three steps: the creation of a cylindrical mold of a glass rod (125 µm) with polystyrene films bearing negative imprints of lotus leaf (superhydrophobic) structures; casting polydimethylsiloxane (PDMS, Sylgard 184) over the mold; and solvent-assisted pulling off of the glass rod to leave a positive replica on the inner wall of the PDMS cast. The last crucial step is achieved through selective dissolution of the intermediate negative replica layer in the cylindrical mold without any swelling effect. The high fidelity of the replication process is confirmed through scanning electron microscope (SEM) imaging. The attained superhydrophobicity is assessed by comparing the dynamics of the advancing meniscus in the fabricated microchannels with that over a similarly fabricated smooth microchannel. Contact angle studies of the meniscus reveal a lower capillary effect and drag force experienced by the superhydrophobic microchannel compared to smooth ones. Studies based on velocity lead to a prediction of a drag reduction of 35%. A new avenue is thus opened up for microfabrication and flow analysis of closed superhydrophobic (SH) conduits in lab on chip and microfluidic applications.

  3. Electroweak bubble wall speed limit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bödeker, Dietrich; Moore, Guy D., E-mail: bodeker@physik.uni-bielefeld.de, E-mail: guymoore@ikp.physik.tu-darmstadt.de

    In extensions of the Standard Model with extra scalars, the electroweak phase transition can be very strong, and the bubble walls can be highly relativistic. We revisit our previous argument that electroweak bubble walls can 'run away,' that is, achieve extreme ultrarelativistic velocities γ ∼ 10{sup 14}. We show that, when particles cross the bubble wall, they can emit transition radiation. Wall-frame soft processes, though suppressed by a power of the coupling α, have a significance enhanced by the γ-factor of the wall, limiting wall velocities to γ ∼ 1/α. Though the bubble walls can move at almost the speedmore » of light, they carry an infinitesimal share of the plasma's energy.« less

  4. Relationship between internal medicine program board examination pass rates, accreditation standards, and program size.

    PubMed

    Falcone, John L; Gonzalo, Jed D

    2014-01-19

    To determine Internal Medicine residency program compliance with the Accreditation Council for Graduate Medical Education 80% pass-rate standard and the correlation between residency program size and performance on the American Board of Internal Medicine Certifying Examination. Using a cross-sectional study design from 2010-2012 American Board of Internal Medicine Certifying Examination data of all Internal Medicine residency pro-grams, comparisons were made between program pass rates to the Accreditation Council for Graduate Medical Education pass-rate standard. To assess the correlation between program size and performance, a Spearman's rho was calculated. To evaluate program size and its relationship to the pass-rate standard, receiver operative characteristic curves were calculated. Of 372 Internal Medicine residency programs, 276 programs (74%) achieved a pass rate of =80%, surpassing the Accreditation Council for Graduate Medical Education minimum standard. A weak correlation was found between residency program size and pass rate for the three-year period (p=0.19, p<0.001). The area underneath the receiver operative characteristic curve was 0.69 (95% Confidence Interval [0.63-0.75]), suggesting programs with less than 12 examinees/year are less likely to meet the minimum Accreditation Council for Graduate Medical Education pass-rate standard (sensitivity 63.8%, specificity 60.4%, positive predictive value 82.2%, p<0.001). Although a majority of Internal Medicine residency programs complied with Accreditation Council for Graduate Medical Education pass-rate standards, a quarter of the programs failed to meet this requirement. Program size is positively but weakly associated with American Board of Internal Medicine Certifying Examination performance, suggesting other unidentified variables significantly contribute to program performance.

  5. 25 CFR 542.17 - What are the minimum internal control standards for complimentary services or items?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 25 Indians 2 2011-04-01 2011-04-01 false What are the minimum internal control standards for complimentary services or items? 542.17 Section 542.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.17 What are the minimum internal control standards for complimentary...

  6. 25 CFR 542.17 - What are the minimum internal control standards for complimentary services or items?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 25 Indians 2 2012-04-01 2012-04-01 false What are the minimum internal control standards for complimentary services or items? 542.17 Section 542.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.17 What are the minimum internal control standards for complimentary...

  7. 25 CFR 542.17 - What are the minimum internal control standards for complimentary services or items?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for complimentary services or items? 542.17 Section 542.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.17 What are the minimum internal control standards for complimentary...

  8. 25 CFR 542.17 - What are the minimum internal control standards for complimentary services or items?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for complimentary services or items? 542.17 Section 542.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.17 What are the minimum internal control standards for complimentary...

  9. Thin-walled reinforcement lattice structure for hollow CMC buckets

    DOEpatents

    de Diego, Peter

    2017-06-27

    A hollow ceramic matrix composite (CMC) turbine bucket with an internal reinforcement lattice structure has improved vibration properties and stiffness. The lattice structure is formed of thin-walled plies made of CMC. The wall structures are arranged and located according to high stress areas within the hollow bucket. After the melt infiltration process, the mandrels melt away, leaving the wall structure to become the internal lattice reinforcement structure of the bucket.

  10. 25 CFR 543.13 - What are the minimum internal control standards for complimentary services or items?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for complimentary services or items? 543.13 Section 543.13 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.13 What are the minimum internal control standards fo...

  11. 25 CFR 543.13 - What are the minimum internal control standards for complimentary services or items?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for complimentary services or items? 543.13 Section 543.13 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.13 What are the minimum internal control standards fo...

  12. 78 FR 14457 - National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-06

    ... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Parts 60 and 63 [EPA-HQ-OAR-2008-0708, FRL-9756-4] RIN 2060-AQ58 National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion Engines; New Source Performance Standards for Stationary Internal Combustion Engines Correction In rule...

  13. 7 CFR 300.5 - International Standards for Phytosanitary Measures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false International Standards for Phytosanitary Measures. 300.5 Section 300.5 Agriculture Regulations of the Department of Agriculture (Continued) ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE INCORPORATION BY REFERENCE § 300.5...

  14. The Internal Medicine of the 21st century: Organizational and operational standards.

    PubMed

    Casariego-Vales, E; Zapatero-Gaviria, A; Elola-Somoza, F J

    2017-12-01

    The Spanish Society of Internal Medicine has developed a consensus document on the standards and recommendations that they consider essential to the organisation of internal medicine units for conducting their activities efficiently and with high quality. We defined 3 groups of key processes: the care of acutely ill adult patients, the comprehensive care of complex chronic patients and the examination of a patient with a difficult diagnosis and no organ-specific disease. As support processes, we identified the structure and operation of the Internal Medicine units. As strategic processes, we identified training and research. The main subprocesses are structured below, and we established the standards and recommendations for each of them. Lastly, we proposed resulting workloads. The prepared standards must be reviewed within a maximum of 4 years. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Medicina Interna (SEMI). All rights reserved.

  15. To recognize the use of international standards for making harmonized regulation of medical devices in Asia-pacific.

    PubMed

    Anand, K; Saini, Ks; Chopra, Y; Binod, Sk

    2010-07-01

    'Medical Devices' include everything from highly sophisticated, computerized, medical equipment, right down to simple wooden tongue depressors. Regulations embody the public expectations for how buildings and facilities are expected to perform and as such represent public policy. Regulators, who develop and enforce regulations, are empowered to act in the public's interest to set this policy and are ultimately responsible to the public in this regard. Standardization contributes to the basic infrastructure that underpins society including health and environment, while promoting sustainability and good regulatory practice. The international organizations that produce International Standards are the International Electrotechnical Commission (IEC), the International Organization for Standardization (ISO), and the International Telecommunication Union (ITU). With the increasing globalization of markets, International Standards (as opposed to regional or national standards) have become critical to the trading process, ensuring a level playing field for exports, and ensuring that imports meet the internationally recognized levels of performance and safety. The development of standards is done in response to sectors and stakeholders that express a clearly established need for them. An industry sector or other stakeholder group typically communicates its requirement for standards to one of the national members. To be accepted for development, a proposed work item must receive a majority support of the participating members, who verify the global relevance of the proposed item. The regulatory authority (RA) should provide a method for the recognition of international voluntary standards and for public notification of such recognition. The process of recognition may vary from country to country. Recognition may occur by periodic publication of lists of standards that a regulatory authority has found will meet the Essential Principles. In conclusion, International standards

  16. 75 FR 80761 - National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-23

    ... National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion Engines... March 3, 2010, final national emission standards for hazardous air pollutants for reciprocating internal... engines to allow emergency engines to operate for up to 15 hours per year as part of an emergency demand...

  17. Discourse Surrounding the International Education Standards for Professional Accountants (IES): A Content Analysis Approach

    ERIC Educational Resources Information Center

    Sugahara, Satoshi; Wilson, Rachel

    2013-01-01

    The development and implementation of the International Education Standards (IES) for professional accountants is currently an important issue in accounting education and for educators interested in a shift toward international education standards more broadly. The purpose of this study is to investigate professional and research discourse…

  18. [International Standards of Tuberculosis Care (ISTC)--comments from the German point of view].

    PubMed

    Castell, S; Bauer, T; Diel, R; Hedrich, A; Magdorf, K; Rüsch-Gerdes, S; Schaberg, T; Loddenkemper, R

    2012-04-01

    The "International Standards for Tuberculosis Care" (ISTC) were developed by the World Health Organisation (WHO) and others to provide internationally agreed and, if possible, evidence-based standards for tuberculosis care including the care by private providers who are not part of national tuberculosis programmes or health-care systems. Hence, the ISTC primarily address resource-restrained countries with high tuberculosis prevalence. In this article, the German translation of the 21 standards from 2009 is presented - addressing diagnostic and therapeutic standards, co-infection (especially with HIV) and public-health issues. The accompanying comments show how these standards have to be modified for Germany due to the medical resources available here and country-specific characteristics respectively. © Georg Thieme Verlag KG Stuttgart · New York.

  19. International standards for programmes of training in intensive care medicine in Europe.

    PubMed

    2011-03-01

    To develop internationally harmonised standards for programmes of training in intensive care medicine (ICM). Standards were developed by using consensus techniques. A nine-member nominal group of European intensive care experts developed a preliminary set of standards. These were revised and refined through a modified Delphi process involving 28 European national coordinators representing national training organisations using a combination of moderated discussion meetings, email, and a Web-based tool for determining the level of agreement with each proposed standard, and whether the standard could be achieved in the respondent's country. The nominal group developed an initial set of 52 possible standards which underwent four iterations to achieve maximal consensus. All national coordinators approved a final set of 29 standards in four domains: training centres, training programmes, selection of trainees, and trainers' profiles. Only three standards were considered immediately achievable by all countries, demonstrating a willingness to aspire to quality rather than merely setting a minimum level. Nine proposed standards which did not achieve full consensus were identified as potential candidates for future review. This preliminary set of clearly defined and agreed standards provides a transparent framework for assuring the quality of training programmes, and a foundation for international harmonisation and quality improvement of training in ICM.

  20. Use of the Ames Check Standard Model for the Validation of Wall Interference Corrections

    NASA Technical Reports Server (NTRS)

    Ulbrich, N.; Amaya, M.; Flach, R.

    2018-01-01

    The new check standard model of the NASA Ames 11-ft Transonic Wind Tunnel was chosen for a future validation of the facility's wall interference correction system. The chosen validation approach takes advantage of the fact that test conditions experienced by a large model in the slotted part of the tunnel's test section will change significantly if a subset of the slots is temporarily sealed. Therefore, the model's aerodynamic coefficients have to be recorded, corrected, and compared for two different test section configurations in order to perform the validation. Test section configurations with highly accurate Mach number and dynamic pressure calibrations were selected for the validation. First, the model is tested with all test section slots in open configuration while keeping the model's center of rotation on the tunnel centerline. In the next step, slots on the test section floor are sealed and the model is moved to a new center of rotation that is 33 inches below the tunnel centerline. Then, the original angle of attack sweeps are repeated. Afterwards, wall interference corrections are applied to both test data sets and response surface models of the resulting aerodynamic coefficients in interference-free flow are generated. Finally, the response surface models are used to predict the aerodynamic coefficients for a family of angles of attack while keeping dynamic pressure, Mach number, and Reynolds number constant. The validation is considered successful if the corrected aerodynamic coefficients obtained from the related response surface model pair show good agreement. Residual differences between the corrected coefficient sets will be analyzed as well because they are an indicator of the overall accuracy of the facility's wall interference correction process.

  1. The protection of migrant workers and international labour standards.

    PubMed

    Bohning, W R

    1988-06-01

    International labor standards take the form of Conventions and Recommendations that embody the agreements reached by a 2/3 majority of the representatives of Governments, Employers, and Workers of International Labour Office (ILO) member states. Originally designed to guard against the danger that 1 country or other would keep down wages and working conditions to gain competitive advantage and thereby undermine advances elsewhere, international labor standards have also been inspired by humanitarian concerns--the visible plight of workers and the physical dangers of industrialization and by the notion of social justice, which embraces wellbeing and dignity, security, and equality as well as a measure of participation in economic and social matters. ILO standards apply to workers generally and therefore also to migrant workers, irrespective of the fact that the general standards are complemented by standards especially for migrant workers. The social security protection of migrant workers has been dealt with in ILO instruments primarily from the angle of equality of treatment but also from that of the maintenance of acquired rights and rights in course of acquisition, including the payment of benefits to entitled persons resident abroad. The ILO Conventions on migrant workers and the Recommendations which supplement them deal with practically all aspects of the work and life of non-nationals such as recruitment matters, information to be made available, contract conditions, medical examination and attention, customs, exemption for personal effects, assistance in settling into their new environment, vocational training, promotion at work, job security and alternative employment, liberty of movement, participation in the cultural life of the state as well as maintenance of their own culture, transfer of earnings and savings, family reunification and visits, appeal against unjustified termination of employment or expulsion, and return assistance. ILO's supervisory

  2. 77 FR 9859 - Lifesaving Equipment: Production Testing and Harmonization With International Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-21

    ... inflatable buoyant apparatuses may be certified using either occupant weight standard. Likewise, equipment...-AB46 Lifesaving Equipment: Production Testing and Harmonization With International Standards AGENCY... lifesaving equipment to harmonize Coast Guard regulations for inflatable liferafts and inflatable buoyant...

  3. Ultrasound wall-sign in pulmonary echinococcosis (new application).

    PubMed

    El Fortia, M; El Gatit, A; Bendaoud, M

    2006-12-01

    We report our experience in diagnosing pulmonary cystic echinococcosis using an ultrasound sign related to the cystic wall. 40 patients with 46 cysts, suspected of pulmonary echinococcosis, based on plain chest radiographs and clinical findings, were examined by ultrasound over a 9-year period (1996 - 2004), and followed up until discharge. We applied our long experience with echinococcal cysts utilising the wall sign (WS) to diagnose pulmonary hydatid disease. All cysts were subject to surgical removal, and postoperative histopathology was the gold standard. There were 34 (74 %) unilocular and 12 (26 %) multivesicular echinococcal cysts. In the univesicular cysts, the WS was found in 20 cases (66.7 %) while it was present in all multivesicular cysts (100 %). Following surgical removal, echinococcosis was confirmed by histopathology in all cases. We conclude that a double layered border in univesicular and double layered internal septum in multivesicular pulmonary echinococcal cysts is a reliable indicator of pulmonary echinococcosis, with a specificity of 66 % and 100 %, respectively.

  4. Do Australian immunoglobulin products meet international measles antibody titer standards?

    PubMed

    Young, Megan K; Bertolini, Joseph; Kotharu, Pushpa; Maher, Darryl; Cripps, Allan W

    2017-03-04

    The effectiveness of passive immunisation post-exposure to measles appears subject to a dose-response effect. New Zealand and the United Kingdom have increased the recommended dose of polyclonal human immunoglobulin for post-exposure prophylaxis within the last decade in response to concerns about decreasing levels of measles antibodies in these products. This study used the plaque-reduction neutralization test (PRNT) to measure the titer of measles-specific antibodies in Australian immunoglobulin products for post-exposure prophylaxis and compared the utility of an enzyme-linked immunosorbent assay (ELISA) to the PRNT in available Australian and international samples: Australian intramuscular (n = 10), Australian intravenous (n = 28), New Zealand intramuscular (n = 2), Hizentra (subcutaneous)(USA) (n = 3), and Privigen (intravenous)(USA) (n = 2). Measles titres in Australian IM and IV immunoglobulins ranged from 51 to 76 IU/mL and 6 to 24 IU/mL respectively, as measured by PRNT calibrated to the WHO 3 rd international standard. ELISA titres were variable but higher than PRNT titres in all tested samples. Measles antibody titres in Australian immunoglobulin products meet consensus-prescribed international thresholds. Development of a convenient, standardized, readily accessible assay for determination of measles titres in immunoglobulin products would be useful for future studies and facilitate international comparisons.

  5. The internal consistency of the standard gamble: tests after adjusting for prospect theory.

    PubMed

    Oliver, Adam

    2003-07-01

    This article reports a study that tests whether the internal consistency of the standard gamble can be improved upon by incorporating loss weighting and probability transformation parameters in the standard gamble valuation procedure. Five alternatives to the standard EU formulation are considered: (1) probability transformation within an EU framework; and, within a prospect theory framework, (2) loss weighting and full probability transformation, (3) no loss weighting and full probability transformation, (4) loss weighting and no probability transformation, and (5) loss weighting and partial probability transformation. Of the five alternatives, only the prospect theory formulation with loss weighting and no probability transformation offers an improvement in internal consistency over the standard EU valuation procedure.

  6. Growth mechanism and internal structure of vertically aligned single-walled carbon nanotubes.

    PubMed

    Einarsson, Erik; Kadowaki, Masayuki; Ogura, Kazuaki; Okawa, Jun; Xiang, Rong; Zhang, Zhengyi; Yamamoto, Takahisa; Ikuhara, Yuichi; Maruyama, Shigeo

    2008-11-01

    An in situ optical absorbance technique was used to monitor the growth of vertically aligned single-walled carbon nanotubes (VA-SWNTs) at various temperatures and pressures. The effects of the growth temperature and ethanol pressure on the initial growth rate and catalyst lifetime were investigated. It was found that the ideal pressure for VA-SWNT synthesis changes with the growth temperature, shifting toward higher pressure as the growth temperature increases. It was also found that the growth reaction is first-order below this ideal pressure. Additionally, the internal structure of the VA-SWNT film was observed at different depths into the film by transmission electron microscopy. The absence of large bundles was confirmed, and little change in the structure was observed to a depth of approximately 1 microm.

  7. Constructing Uniformity: the Standardization of International Electromagnetic Measures, 1860-1912

    NASA Astrophysics Data System (ADS)

    Lagerstrom, Larry Randles

    Metrology gained much attention from electrical scientists and practitioners in the nineteenth and early twentieth centuries. Spurred by the expanding telegraph industries, they considered the construction and acceptance of a universal system of electromagnetic measures essential for the growth of science and technology. The task was not easy. Scientists and practitioners, having different concerns and needs, often found themselves at odds. National rivalries further obstructed the attainment of uniform measures. Under the auspices of a series of international electrical congresses and conferences between 1881 and 1908, the systembuilders succeeded in establishing an international system of practical electrical units and standards--the ohm, volt, ampere, coulomb, farad, joule, and watt--based on the centimeter-gram-second (CGS) system of measures. They had less success, however, with practical magnetic units. They had designed the system of electrical units to meet the needs of telegraphy. But the rise of the technologies of electrical power in the late nineteenth century made it difficult to define magnetic units that were both practical for the new technologies and coherent with the existing system of units. The international congress, as an institution, also gave them trouble. It lacked authority and stability and, in some cases, hindered the development of the system of units. More credit for the success of the systembuilders must go, paradoxically, to the national physical laboratories that arose in Germany, France, Great Britain, and the United States circa 1900. They enabled the standardization of international electromagnetic measures by narrowing the community of systembuilders to a small circle of elite experts. This historical process illustrates important aspects of the ways and means of standardization, of the technical and social construction of uniformity.

  8. 78 FR 987 - Hazardous Materials: Harmonization with International Standards (RRR)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-07

    ...PHMSA is amending the Hazardous Materials Regulations to maintain alignment with international standards by incorporating various amendments, including changes to proper shipping names, hazard classes, packing groups, special provisions, packaging authorizations, air transport quantity limitations, and vessel stowage requirements. These revisions are necessary to harmonize the Hazardous Materials Regulations (HMR) with recent changes made to the International Maritime Dangerous Goods (IMDG) Code, the International Civil Aviation Organization's Technical Instructions for the Safe Transport of Dangerous Goods by Air (ICAO Technical Instructions), and the United Nations Recommendations on the Transport of Dangerous Goods--Model Regulations (UN Model Regulations) and address a petition for rulemaking.

  9. 77 FR 49167 - Hazardous Materials: Harmonization with International Standards (RRR)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-15

    ...PHMSA proposes to amend the Hazardous Materials Regulations to maintain alignment with international standards by incorporating various amendments, including changes to proper shipping names, hazard classes, packing groups, special provisions, packaging authorizations, air transport quantity limitations, and vessel stowage requirements. These revisions are necessary to harmonize the Hazardous Materials Regulations with recent changes made to the International Maritime Dangerous Goods Code, the International Civil Aviation Organization's Technical Instructions for the Safe Transport of Dangerous Goods by Air, and the United Nations Recommendations on the Transport of Dangerous Goods--Model Regulations and subsequently address a petition for rulemaking.

  10. Assessment of opacimeter calibration according to International Standard Organization 10155.

    PubMed

    Gomes, J F

    2001-01-01

    This paper compares the calibration method for opacimeters issued by the International Standard Organization (ISO) 10155 with the manual reference method for determination of dust content in stack gases. ISO 10155 requires at least nine operational measurements, corresponding to three operational measurements per each dust emission range within the stack. The procedure is assessed by comparison with previous calibration methods for opacimeters using only two operational measurements from a set of measurements made at stacks from pulp mills. The results show that even if the international standard for opacimeter calibration requires that the calibration curve is to be obtained using 3 x 3 points, a calibration curve derived using 3 points could be, at times, acceptable in statistical terms, provided that the amplitude of individual measurements is low.

  11. Tube wall thickness measurement apparatus

    DOEpatents

    Lagasse, P.R.

    1985-06-21

    An apparatus for measuring the thickness of a tube's wall for the tube's entire length and radius by determining the deviation of the tube wall thickness from the known thickness of a selected standard item. The apparatus comprises a base and a first support member having first and second ends. The first end is connected to the base and the second end is connected to a spherical element. A second support member is connected to the base and spaced apart from the first support member. A positioning element is connected to and movable relative to the second support member. An indicator is connected to the positioning element and is movable to a location proximate the spherical element. The indicator includes a contact ball for first contacting the selected standard item and holding it against the spherical element. The contact ball then contacts the tube when the tube is disposed about the spherical element. The indicator includes a dial having a rotatable needle for indicating the deviation of the tube wall thickness from the thickness of the selected standard item.

  12. Tube wall thickness measurement apparatus

    DOEpatents

    Lagasse, Paul R.

    1987-01-01

    An apparatus for measuring the thickness of a tube's wall for the tube's entire length and circumference by determining the deviation of the tube wall thickness from the known thickness of a selected standard item. The apparatus comprises a base and a first support member having first and second ends. The first end is connected to the base and the second end is connected to a spherical element. A second support member is connected to the base and spaced apart from the first support member. A positioning element is connected to and movable relative to the second support member. An indicator is connected to the positioning element and is movable to a location proximate the spherical element. The indicator includes a contact ball for first contacting the selected standard item and holding it against the spherical element. The contact ball then contacts the tube when the tube is disposed about the spherical element. The indicator includes a dial having a rotatable needle for indicating the deviation of the tube wall thickness from the thickness of the selected standard item.

  13. Comparison of FRA regulations to international high-speed rail standards.

    DOT National Transportation Integrated Search

    2013-05-01

    This report compares international standards with selected parts of Federal Railroad Administration (FRA) Code of Federal Regulation Title 49 CFR Transportation. The parts were preselected by FRA and are meant to reflect those areas of the regulation...

  14. How Two Small Pharmacy Schools' Competency Standards Compare with an International Competency Framework and How Well These Schools Prepare Students for International Placements.

    PubMed

    Hawboldt, John; Nash, Rose; FitzPatrick, Beverly

    2017-03-06

    International standards of pharmacy curricula are necessary to ensure student readiness for international placements. This paper explores whether curricula from two pharmacy programs, in Australia and Canada, are congruent with international standards and if students feel prepared for international placements. Nationally prescribed educational standards for the two schools were compared to each other and then against the International Pharmaceutical Federation (FIP) Global Competency Framework. Written student reflections complemented this analysis. Mapping results suggested substantial agreement between the FIP framework and Australia and Canada, with two gaps being identified. Moreover, the students felt their programs prepared them for their international placements. Despite differences in countries, pharmacy programs, and health-systems all students acclimatized to their new practice sites. Implications are that if pharmacy programs align well with FIP, pharmacists should be able to integrate and practise in other jurisdictions that also align with the FIP. This has implications for the mobility of pharmacy practitioners to countries not of their origin of training.

  15. Correction for isotopic interferences between analyte and internal standard in quantitative mass spectrometry by a nonlinear calibration function.

    PubMed

    Rule, Geoffrey S; Clark, Zlatuse D; Yue, Bingfang; Rockwood, Alan L

    2013-04-16

    Stable isotope-labeled internal standards are of great utility in providing accurate quantitation in mass spectrometry (MS). An implicit assumption has been that there is no "cross talk" between signals of the internal standard and the target analyte. In some cases, however, naturally occurring isotopes of the analyte do contribute to the signal of the internal standard. This phenomenon becomes more pronounced for isotopically rich compounds, such as those containing sulfur, chlorine, or bromine, higher molecular weight compounds, and those at high analyte/internal standard concentration ratio. This can create nonlinear calibration behavior that may bias quantitative results. Here, we propose the use of a nonlinear but more accurate fitting of data for these situations that incorporates one or two constants determined experimentally for each analyte/internal standard combination and an adjustable calibration parameter. This fitting provides more accurate quantitation in MS-based assays where contributions from analyte to stable labeled internal standard signal exist. It can also correct for the reverse situation where an analyte is present in the internal standard as an impurity. The practical utility of this approach is described, and by using experimental data, the approach is compared to alternative fits.

  16. RADIOAUTOGRAPHIC STUDY OF CELL WALL DEPOSITION IN GROWING PLANT CELLS

    PubMed Central

    Ray, Peter M.

    1967-01-01

    Segments cut from growing oat coleoptiles and pea stems were fed glucose-3H in presence and absence of the growth hormone indoleacetic acid (IAA). By means of electron microscope radioautography it was demonstrated that new cell wall material is deposited both at the wall surface (apposition) and within the preexisting wall structure (internally). Quantitative profiles for the distribution of incorporation with position through the thickness of the wall were obtained for the thick outer wall of epidermal cells. With both oat coleoptile and pea stem epidermal outer walls, it was found that a larger proportion of the newly synthesized wall material appeared to become incorporated within the wall in the presence of IAA. Extraction experiments on coleoptile tissue showed that activity that had been incorporated into the cell wall interior represented noncellulosic constituents, mainly hemicelluloses, whereas cellulose was deposited largely or entirely by apposition. It seems possible that internal incorporation of hemicelluloses plays a role in the cell wall expansion process that is involved in cell growth. PMID:6064369

  17. Report of the Task Force on Testing Standards (TFTS) to the International Language Testing Association (ILTA).

    ERIC Educational Resources Information Center

    International Language Testing Association.

    The Task Force on Testing Standards (TFTS) of the International Language Testing Association was charged to produce a report of an international survey of language assessment standards, to provide for exchange of information on standards and for development of a code of practice. Contact with individuals in both language testing and the broader…

  18. Assay of potency of the proposed Fifth International Standard for Gas-Gangrene Antitoxin (Perfringens)

    PubMed Central

    Prigge, R.; Micke, H.; Krüger, J.

    1963-01-01

    As part of a collaborative assay of the proposed Fifth International Standard for Gas-Gangrene Antitoxin (Perfringens), five ampoules of the proposed replacement material were assayed in the authors' laboratory against the then current Fourth International Standard. Both in vitro and in vivo methods were used. This paper presents the results and their statistical analysis. The two methods yielded different results which were not likely to have been due to chance, but exact statistical comparison is not possible. It is thought, however, that the differences may be due, at least in part, to differences in the relative proportions of zeta-antitoxin and alpha-antitoxin in the Fourth and Fifth International Standards and the consequent different reactions with the test toxin that was used for titration. PMID:14107746

  19. International Cooperation for a Single World Production Standard of High Definition Television.

    ERIC Educational Resources Information Center

    Hongcharu, Boonchai

    Broadcasters, television engineers and the production industry have encountered many problems with diverse television standards since the introduction of color television. With the advent of high definition television (HDTV), the chance to have a common production standard for international exchange of programs and technical information has…

  20. [The use of a prolene double mesh for orbital wall reconstruction].

    PubMed

    Junceda-Moreno, J; Suárez-Suárez, E; Dos-Santos-Bernardo, V

    2005-08-01

    Patient with a recurrent carcinoma of the nasal fossae affecting the internal orbital wall. The intraorbital content was not affected. The orbital wall was reconstructed with a prolene double mesh anchored to the periosteum. Prolene mesh as a substitute of the orbital wall. Good stability and isolation of the intraorbital structures were observed. Ocular motility was completely normal after surgery without prolene mesh displacements. The prolene double mesh is a good surgical option to replace missing bone in the reconstruction of the internal orbital wall.

  1. Coronary artery wall imaging.

    PubMed

    Keegan, Jennifer

    2015-05-01

    Like X-Ray contrast angiography, MR coronary angiograms show the vessel lumens rather than the vessels themselves. Consequently, outward remodeling of the vessel wall, which occurs in subclinical coronary disease before luminal narrowing, cannot be seen. The current gold standard for assessing the coronary vessel wall is intravascular ultrasound, and more recently, optical coherence tomography, both of which are invasive and use ionizing radiation. A noninvasive, low-risk technique for assessing the vessel wall would be beneficial to cardiologists interested in the early detection of preclinical disease and for the safe monitoring of the progression or regression of disease in longitudinal studies. In this review article, the current state of the art in MR coronary vessel wall imaging is discussed, together with validation studies and recent developments. © 2014 Wiley Periodicals, Inc.

  2. Analytical Investigation of Elastic Thin-Walled Cylinder and Truncated Cone Shell Intersection Under Internal Pressure.

    PubMed

    Zamani, J; Soltani, B; Aghaei, M

    2014-10-01

    An elastic solution of cylinder-truncated cone shell intersection under internal pressure is presented. The edge solution theory that has been used in this study takes bending moments and shearing forces into account in the thin-walled shell of revolution element. The general solution of the cone equations is based on power series method. The effect of cone apex angle on the stress distribution in conical and cylindrical parts of structure is investigated. In addition, the effect of the intersection and boundary locations on the circumferential and longitudinal stresses is evaluated and it is shown that how quantitatively they are essential.

  3. DEVELOPMENT OF INTERNATIONAL STANDARDS FOR AIR QUALITY MONITORING AND CONTROL

    EPA Science Inventory

    This report presents a description of the activities and accomplishments of the American Society for Testing and Materials' U. S. Technical Advisory Group (TAG) to the International Standards Organization's Technical Committee 146 on Air Quality. The purpose of the TAG is to re...

  4. 25 CFR 543.23 - What are the minimum internal control standards for audit and accounting?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... supervision, bingo cards, bingo card sales, draw, prize payout; cash and equivalent controls, technologic aids... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for audit... INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.23 What are the...

  5. 25 CFR 543.23 - What are the minimum internal control standards for audit and accounting?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... supervision, bingo cards, bingo card sales, draw, prize payout; cash and equivalent controls, technologic aids... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for audit... INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.23 What are the...

  6. Collaborative study for the establishment of the 4(th) International Standard for Streptomycin.

    PubMed

    Jorajuria, S; Raphalen, C; Dujardin, V; Daas, A

    2015-01-01

    An international collaborative study was organised to establish the 4(th) World Health Organization (WHO) International Standard (IS) for Streptomycin. Fourteen laboratories from different countries participated. Potencies of the candidate material were estimated by microbiological assays with sensitive micro-organisms. To ensure continuity between consecutive batches, the 3(rd) IS for Streptomycin was used as a reference. Based on the results of the study, the 4(th) IS for Streptomycin was adopted at the meeting of the WHO Expert Committee for Biological Standardization (ECBS) in 2015 with an assigned potency of 76 000 International Units (IU) per vial. The 4(th) IS for Streptomycin is available from the European Directorate for the Quality of Medicines & HealthCare (EDQM).

  7. Commercial versus Internally Developed Standardized Tests: Lessons from a Small Regional School

    ERIC Educational Resources Information Center

    Hadjicharalambous, Costas

    2014-01-01

    The author compares the efficacy of commercially available and internally developed standardized tests and evaluates their strengths and weakness in assessing student learning outcomes. The author shares the experience of a regional school in developing a standardized test to assess business knowledge. Data from a sample of 268 students were used…

  8. Monte Carlo Simulation to Determine Geometry Effects on Quantitative X-ray Microanalysis in Plant Cell Walls Using Gelatin Standards

    NASA Astrophysics Data System (ADS)

    Tylko, Grzegorz; Dubchak, Sergyi; Banach, Zuzanna; Turnau, Katarzyna

    2010-04-01

    Monte Carlo simulations of gelatin matrices with known elemental concentrations confirmed the suitability of protein standards to quantify elements of cellulose material in x-ray microanalysis. However, gelatin standards and cellulose plant cell walls differ in structure, what influences x-ray generation and emission in both specimens. The goal of the project was to establish the influence of gelatin structure on x-ray generation and its usefulness to calculate elemental concentrations in plant cell walls of different width. Roots of Medicago truncatula as well as gelatin standards with known elemental composition were prepared according to freeze-drying protocols. The thermanox polymer was chosen to establish background formation for flat and compact organic materials. All analyses were performed with the scanning electron microscope operated at 10 keV and probe current of 350 pA. The Monte Carlo code Casino was applied to calculate the intensities of the generated and the emitted x-rays from biological matrix of different width. No topography effects of gelatin structure were visible when the raster mode of electron impact was applied to the specimen. Monte Carlo simulations of gelatin of different width revealed that a significant decrease of the generated x-ray intensity appears at the width of the specimen around 3.5 μm. However, an increase of emission of low energy x-ray intensities (Na, Mg) was noted at 3.5 μm size with constant emission of higher energy x-rays (Cl, K) down to 2.5 μm width. It determines the minimal size of plant specimen useful for comparison to bulk gelatin standard when quantitative analysis is performed for biologically important elements.

  9. Problems of the development of international standards of “green building” in Russia

    NASA Astrophysics Data System (ADS)

    Meshcheryakova, Tatiana

    2017-10-01

    Problems of environmental friendliness and energy efficiency in recent decades have become not only the most important issues of economic development of the main industrial economies, but also the basis for the processes of maintaining the security and relative stability of the global ecosystem. The article presents the results of the study of the status and trends of the development of environmental standards for the construction and maintenance of real estate in the world and particularly in Russia. Special market instruments for assessing the compliance with the quality of real estate projects under construction and modern principles of environmental friendliness and energy efficiency include voluntary building certification systems that are actively used in international practice. In Russia there is active use of the following international systems of certification: BREEAM, LEED, DGNB, HQE. Also in the Russian certification market, the national standard STO NOSTROY 2.35.4-2011 “Residential and public buildings” is being implemented, which summarizes the best international experience of the rating evaluation procedure. Comparative characteristics of the “green” standards and the principles of rating assessments of the ecological compatibility of buildings give an idea of applying these standards in Russia.

  10. 76 FR 65166 - International Sanitary and Phytosanitary Standard-Setting Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-20

    ..., formerly known as the Office International des Epizooties) regarding animal health and welfare, and... bulletins on global disease status, and provides animal disease control guidelines to Members. Various OIE commissions and working groups undertake the development and preparation of draft standards, which are then...

  11. Assessing the properties of internal standards for quantitative matrix-assisted laser desorption/ionization mass spectrometry of small molecules.

    PubMed

    Sleno, Lekha; Volmer, Dietrich A

    2006-01-01

    Growing interest in the ability to conduct quantitative assays for small molecules by matrix-assisted laser desorption/ionization (MALDI) has been the driving force for several recent studies. This present work includes the investigation of internal standards for these analyses using a high-repetition rate MALDI triple quadrupole instrument. Certain physicochemical properties are assessed for predicting possible matches for internal standards for different small molecules. The importance of similar molecular weight of an internal standard to its analyte is seen through experiments with a series of acylcarnitines, having a fixed charge site and growing alkyl chain length. Both acetyl- and hexanoyl-carnitine were systematically assessed with several other acylcarnitine compounds as internal standards. The results clearly demonstrate that closely matched molecular weights between analyte and internal standard are essential for acceptable quantitation results. Using alpha-cyano-4-hydroxycinnamic acid as the organic matrix, the similarities between analyte and internal standard remain the most important parameter and not necessarily their even distribution within the solid sample spot. Several 4-quinolone antibiotics as well as a diverse group of pharmaceutical drugs were tested as internal standards for the 4-quinolone, ciprofloxacin. Quantitative results were shown using the solution-phase properties, log D and pKa, of these molecules. Their distribution coefficients, log D, are demonstrated as a fundamental parameter for similar crystallization patterns of analyte and internal standard. In the end, it was also possible to quantify ciprofloxacin using a drug from a different compound class, namely quinidine, having a similar log D value as the analyte. Copyright 2006 John Wiley & Sons, Ltd.

  12. Research on Reasons for Repeated Falling of Tiles in Internal Walls of Construction

    NASA Astrophysics Data System (ADS)

    Xu, LiBin; Chen, Shangwei; He, Xinzhou; Zhu, Guoliang

    2018-03-01

    In view of the quality problem of repeated falling of facing tiles in some construction, the essay had a comparative trial in laboratory on cement mortar which is often used to paste tiles, special tile mortar and dry-hang glue, and measured durability of tile adhesive mortar through freezing and thawing tests. The test results indicated that ordinary cement mortar cannot meet standards due to reasons like big shrinkage and low adhesive. In addition, the ten times of freezing and thawing tests indicated that ordinary cement mortar would directly shell and do not have an adhesive force, and moreover, adhesive force of special tile mortar would reduce. Thus, for tiles of large size which are used for walls, dry-hang techniques are recommended to be used.

  13. Updating the International Standards for Tuberculosis Care. Entering the era of molecular diagnostics.

    PubMed

    Hopewell, Philip C; Fair, Elizabeth L; Uplekar, Mukund

    2014-03-01

    The International Standards for Tuberculosis Care, first published in 2006 (Lancet Infect Dis 2006;6:710-725.) with a second edition in 2009 ( www.currytbcenter.ucsf.edu/international/istc_report ), was produced by an international coalition of organizations funded by the United States Agency for International Development. Development of the document was led jointly by the World Health Organization and the American Thoracic Society, with the aim of promoting engagement of all care providers, especially those in the private sector in low- and middle-income countries, in delivering high-quality services for tuberculosis. In keeping with World Health Organization recommendations regarding rapid molecular testing, as well as other pertinent new recommendations, the third edition of the Standards has been developed. After decades of dormancy, the technology available for tuberculosis care and control is now rapidly evolving. In particular, rapid molecular testing, using devices with excellent performance characteristics for detecting Mycobacterium tuberculosis and rifampin resistance, and that are practical and affordable for use in decentralized facilities in low-resource settings, is being widely deployed globally. Used appropriately, both within tuberculosis control programs and in private laboratories, these devices have the potential to revolutionize tuberculosis care and control, providing a confirmed diagnosis and a determination of rifampin resistance within a few hours, enabling appropriate treatment to be initiated promptly. Major changes have been made in the standards for diagnosis. Additional important changes include: emphasis on the recognition of groups at increased risk of tuberculosis; updating the standard on antiretroviral treatment in persons with tuberculosis and human immunodeficiency virus infection; and revising the standard on treating multiple drug-resistant tuberculosis.

  14. 78 FR 8431 - Hazardous Materials: Harmonization with International Standards (RRR)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-06

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration 49 CFR Part 172 [Docket Nos. PHMSA-2012-0027 (HM-215L)] RIN 2137-AE87 Hazardous Materials: Harmonization with International Standards (RRR) Correction In rule document 2012-31243 appearing on pages 988 through 1100 in the...

  15. The role of international standards in managing business risks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mazza, S.

    1996-08-01

    Strategic standardization is an emerging management discipline which is gaining a slow but upward acceptance by many American business leaders. It is a management discipline widely followed by European business managers for a long time to ensure a strong competitive position in the global marketplace. American businesses are increasingly adapting this concept for effective management to open new markets, increase sales, reduce trade barriers, and ensure a competitive position both domestically as well as the international arena. Contrary to the view that standardization is only a technical strategy, there is a new reality that standardization is a critical business issuemore » with implications for market access, anti-trust, product liability, patent policy and protection, occupational, health safety, environmental management, government acquisition reform, and even our quality of life. It is often stated, standards are like the air we breathe always accepted and taken for granted until there is a problem of supply or in the case of standards, when they are used as a trade barrier or competitive advantage for others or used to create substantial liabilities for businesses and for individuals.« less

  16. The international growth standard for preadolescent and adolescent children: statistical considerations.

    PubMed

    Cole, T J

    2006-12-01

    This article discusses statistical considerations for the design of a new study intended to provide an International Growth Standard for Preadolescent and Adolescent Children, including issues such as cross-sectional, longitudinal, and mixed designs; sample-size derivation for the number of populations and number of children per population; modeling of growth centiles of height, weight, and other measurements; and modeling of the adolescent growth spurt. The conclusions are that a mixed longitudinal design will provide information on both growth distance and velocity; samples of children from 5 to 10 sites should be suitable for an international standard (based on political rather than statistical arguments); the samples should be broadly uniform across age but oversampled during puberty, and should include data into adulthood. The LMS method is recommended for constructing measurement centiles, and parametric or semiparametric approaches are available to estimate the timing of the adolescent growth spurt in individuals. If the new standard is to be grafted onto the 2006 World Health Organization (WHO) reference, caution is needed at the join point of 5 years, where children from the new standard are likely to be appreciably more obese than those from the WHO reference, due to the rising trends in obesity and the time gap in data collection between the two surveys.

  17. Multiplicative effects model with internal standard in mobile phase for quantitative liquid chromatography-mass spectrometry.

    PubMed

    Song, Mi; Chen, Zeng-Ping; Chen, Yao; Jin, Jing-Wen

    2014-07-01

    Liquid chromatography-mass spectrometry assays suffer from signal instability caused by the gradual fouling of the ion source, vacuum instability, aging of the ion multiplier, etc. To address this issue, in this contribution, an internal standard was added into the mobile phase. The internal standard was therefore ionized and detected together with the analytes of interest by the mass spectrometer to ensure that variations in measurement conditions and/or instrument have similar effects on the signal contributions of both the analytes of interest and the internal standard. Subsequently, based on the unique strategy of adding internal standard in mobile phase, a multiplicative effects model was developed for quantitative LC-MS assays and tested on a proof of concept model system: the determination of amino acids in water by LC-MS. The experimental results demonstrated that the proposed method could efficiently mitigate the detrimental effects of continuous signal variation, and achieved quantitative results with average relative predictive error values in the range of 8.0-15.0%, which were much more accurate than the corresponding results of conventional internal standard method based on the peak height ratio and partial least squares method (their average relative predictive error values were as high as 66.3% and 64.8%, respectively). Therefore, it is expected that the proposed method can be developed and extended in quantitative LC-MS analysis of more complex systems. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. The Role of Internal Standards and their Interaction with Soils Impact Accuracy of Volatile Organics Determinations

    EPA Science Inventory

    Both US Environmental Protection Agency (EPA) SW-846 Methods 8260C/5035 and 8261A include mixing soil with water and addition of internal standards prior to analyses but the equilibration of internal standards with the soil is not required. With increasing total organic carbon (...

  19. National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion Engines

    EPA Pesticide Factsheets

    This page contains the current National Emission Standards for Hazardous Air Pollutants (NESHAP) for Reciprocating Internal Combustion Engines and additional information regarding rule compliance and implementation.

  20. Thermal Performance Evaluation of Walls with Gas Filled Panel Insulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shrestha, Som S.; Desjarlais, Andre Omer; Atchley, Jerald Allen

    Gas filled insulation panels (GFP) are very light weight and compact (when uninflated) advanced insulation products. GFPs consist of multiple layers of thin, low emittance (low-e) metalized aluminum. When expanded, the internal, low-e aluminum layers form a honeycomb structure. These baffled polymer chambers are enveloped by a sealed barrier and filled with either air or a low-conductivity gas. The sealed exterior aluminum foil barrier films provide thermal resistance, flammability protection, and properties to contain air or a low conductivity inert gas. This product was initially developed with a grant from the U.S. Department of Energy. The unexpanded product is nearlymore » flat for easy storage and transport. Therefore, transportation volume and weight of the GFP to fill unit volume of wall cavity is much smaller compared to that of other conventional insulation products. This feature makes this product appealing to use at Army Contingency Basing, when transportation cost is significant compared to the cost of materials. The objective of this study is to evaluate thermal performance of walls, similar to those used at typical Barracks Hut (B-Hut) hard shelters, when GFPs are used in the wall cavities. Oak Ridge National Laboratory (ORNL) tested performance of the wall in the rotatable guarded hotbox (RGHB) according to the ASTM C 1363 standard test method.« less

  1. Unsteady Heat Transfer Behavior of Reinforced Concrete Wall of Cold Storage

    NASA Astrophysics Data System (ADS)

    Nomura, Tomohiro; Murakami, Yuji; Uchikawa, Motoyuki

    The authors had already clarified that the heat transfer behaviors between internal and external insulated reinforced concrete wall of cold storage are different each others when inside and outside temperature of wall is flactuating. From that conclusion, we must consider the application method of wall insulation of cold storages in actual design. The theme of the paper is to get the analyzing method and unsteady heat transfer characteristics of concrete walls of cold storage during daily variation of outside temperature of walls, and to give the basis for efficient design and cost optimization of insulate wall of cold storage. The difference of unsteady heat transfer characteristics between internal and external insulate wall, when outside temperature of the wall follewed daily varation, was clarified in experiment and in situ measurement of practical cold storage. The analyzing method with two dimentional unsteady FEM was introduced. Using this method, it is possible to obtain the time variation of heat flux, which is important basic factor for practical design of cold storage, through the wall.

  2. Concept for an International Standard related to Space Weather Effects on Space Systems

    NASA Astrophysics Data System (ADS)

    Tobiska, W. Kent; Tomky, Alyssa

    There is great interest in developing an international standard related to space weather in order to specify the tools and parameters needed for space systems operations. In particular, a standard is important for satellite operators who may not be familiar with space weather. In addition, there are others who participate in space systems operations that would also benefit from such a document. For example, the developers of software systems that provide LEO satellite orbit determination, radio communication availability for scintillation events (GEO-to-ground L and UHF bands), GPS uncertainties, and the radiation environment from ground-to-space for commercial space tourism. These groups require recent historical data, current epoch specification, and forecast of space weather events into their automated or manual systems. Other examples are national government agencies that rely on space weather data provided by their organizations such as those represented in the International Space Environment Service (ISES) group of 14 national agencies. Designers, manufacturers, and launchers of space systems require real-time, operational space weather parameters that can be measured, monitored, or built into automated systems. Thus, a broad scope for the document will provide a useful international standard product to a variety of engineering and science domains. The structure of the document should contain a well-defined scope, consensus space weather terms and definitions, and internationally accepted descriptions of the main elements of space weather, its sources, and its effects upon space systems. Appendices will be useful for describing expanded material such as guidelines on how to use the standard, how to obtain specific space weather parameters, and short but detailed descriptions such as when best to use some parameters and not others; appendices provide a path for easily updating the standard since the domain of space weather is rapidly changing with new advances

  3. Dispersive aortic cannulas reduce aortic wall shear stress affecting atherosclerotic plaque embolization.

    PubMed

    Assmann, Alexander; Gül, Fethi; Benim, Ali Cemal; Joos, Franz; Akhyari, Payam; Lichtenberg, Artur

    2015-03-01

    Neurologic complications during on-pump cardiovascular surgery are often induced by mobilization of atherosclerotic plaques, which is directly related to enhanced wall shear stress. In the present study, we numerically evaluated the impact of dispersive aortic cannulas on aortic blood flow characteristics, with special regard to the resulting wall shear stress profiles. An idealized numerical model of the human aorta and its branches was created and used to model straight as well as bent dispersive aortic cannulas with meshlike tips inserted in the distal ascending aorta. Standard cannulas with straight beveled or bent tips served as controls. Using a recently optimized computing method, simulations of pulsatile and nonpulsatile extracorporeal circulation were performed. Dispersive aortic cannulas reduced the maximum and average aortic wall shear stress values to approximately 50% of those with control cannulas, while the difference in local values was even larger. Moreover, under pulsatile circulation, dispersive cannulas shortened the time period during which wall shear stress values were increased. The turbulent kinetic energy was also diminished by utilizing dispersive cannulas, reducing the risk of hemolysis. In summary, dispersive aortic cannulas decrease aortic wall shear stress and turbulence during extracorporeal circulation and may therefore reduce the risk of endothelial and blood cell damage as well as that of neurologic complications caused by atherosclerotic plaque mobilization. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  4. How to Integrate International Financial Reporting Standards into Accounting Programs

    ERIC Educational Resources Information Center

    Singer, Robert A.

    2012-01-01

    It is expected the SEC will require U.S. domestic companies to prepare and file their annual 10Ks in accordance with international financial reporting standards (IFRS) by 2016. Given the probability that the FASB-IASB convergence project (i.e., Norwalk Agreement) will continue subsequent to mandatory adoption, US accounting programs will be…

  5. What consequences should result from failure to meet internal standards?

    PubMed

    Schramm, J

    1997-01-01

    This paper tries to approach a difficult problem, namely how to deal with a resident who has failed to meet the internal standards of a residency training program. First the problems of the definition of a standard and the associated problems of its reproducibility, documentation, teaching, update, and internal variability inside the same teaching program are dealt with. Consequently the question needs to be answered that constitutes a failure to meet the standard. The results of a survey of residents' attitudes are quoted as are some responses to a survey among the chiefs of teaching programs. Considering the attitudes of residents on how to handle breaches of standard the basic message was that residents want to be told that they do not function. Both parties want the collaboration of senior staff members on this topic. Whereas residents want to re-train, exercise and talk they do not want sanctions. Chiefs, however, want much less re-training, exercising and talking but earlier sanction. The difficult point of dealing with a true failure is discussed in the light of the German legal situation and the actual possibilities of how to handle the case. Before it comes to the point of discontinuing the training of a resident, it needs to be agreed upon what would be a classical situation of failure in which both the chiefs responsible for training and the residents agree that training is better discontinued. The author describes his experience with the real course of events in 7 cases he witnessed in 22 years.

  6. Accurate determination of arsenic in arsenobetaine standard solutions of BCR-626 and NMIJ CRM 7901-a by neutron activation analysis coupled with internal standard method.

    PubMed

    Miura, Tsutomu; Chiba, Koichi; Kuroiwa, Takayoshi; Narukawa, Tomohiro; Hioki, Akiharu; Matsue, Hideaki

    2010-09-15

    Neutron activation analysis (NAA) coupled with an internal standard method was applied for the determination of As in the certified reference material (CRM) of arsenobetaine (AB) standard solutions to verify their certified values. Gold was used as an internal standard to compensate for the difference of the neutron exposure in an irradiation capsule and to improve the sample-to-sample repeatability. Application of the internal standard method significantly improved linearity of the calibration curve up to 1 microg of As, too. The analytical reliability of the proposed method was evaluated by k(0)-standardization NAA. The analytical results of As in AB standard solutions of BCR-626 and NMIJ CRM 7901-a were (499+/-55)mgkg(-1) (k=2) and (10.16+/-0.15)mgkg(-1) (k=2), respectively. These values were found to be 15-20% higher than the certified values. The between-bottle variation of BCR-626 was much larger than the expanded uncertainty of the certified value, although that of NMIJ CRM 7901-a was almost negligible. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  7. ASTM International Workshop on Standards & Measurements for Tissue Engineering Scaffolds

    PubMed Central

    Simon, Carl G.; Yaszemski, Michael J.; Ratcliffe, Anthony; Tomlins, Paul; Luginbuehl, Reto; Tesk, John A.

    2016-01-01

    The “Workshop on Standards & Measurements for Tissue Engineering Scaffolds” was held on May 21, 2013 in Indianapolis, IN and was sponsored by the ASTM International (ASTM). The purpose of the workshop was to identify the highest priority items for future standards work for scaffolds used in the development and manufacture of tissue engineered medical products (TEMPs). Eighteen speakers and 78 attendees met to assess current scaffold standards and to prioritize needs for future standards. A key finding was that the ASTM TEMPs subcommittees (F04.41-46) have many active “guide” documents for educational purposes, but that few standard “test methods” or “practices” have been published. Overwhelmingly, the most clearly identified need was standards for measuring the structure of scaffolds, followed by standards for biological characterization, including in vitro testing, animal models and cell-material interactions. The third most pressing need was to develop standards for assessing the mechanical properties of scaffolds. Additional needs included standards for assessing scaffold degradation, clinical outcomes with scaffolds, effects of sterilization on scaffolds, scaffold composition and drug release from scaffolds. Discussions also highlighted the need for additional scaffold reference materials and the need to use them for measurement traceability. Finally, dialogue emphasized the needs to promote the use of standards in scaffold fabrication, characterization, and commercialization and to assess the use and impact of standards in the TEMPs community. Many scaffold standard needs have been identified and focus should now turn to generating these standards to support the use of scaffolds in TEMPs. PMID:25220952

  8. Collaborative study to assess the suitability of a candidate International Standard for yellow fever vaccine.

    PubMed

    Ferguson, Morag; Heath, Alan

    2004-12-01

    Yellow fever vaccines are routinely assayed by plaque assay. However, the results of these assays are then converted into mouse LD(50) using correlations/conversion factors which, in many cases, were established many years ago. The minimum required potency in WHO Recommendations is 10(3) LD(50)/dose. Thirteen participants from 8 countries participated in a collaborative study whose aim was to assess the suitability of two candidate preparations to serve as an International Standard for yellow fever vaccine. In addition, the study investigated the relationship between the mouse LD(50) test and plaque forming units with a view to updating the WHO recommendations. Plaque assays were more reproducible than mouse assays, as expected. Differences in sensitivities of plaque assays were observed between laboratories but these differences appear to be consistent within a laboratory for all samples and the expression of potency relative to the candidate standard vaccine improved the reproducibility of assays between laboratories. However, the use of potencies had little effect on the between laboratory variability in mouse LD(50) assays. There appears to be a consistent relationship between overall mean LD(50) and plaques titre for all study preparations other than sample E. The slope of the correlation curve is >1 and it would appear that 10(3) LD(50) is approximately equivalent to 10(4) plaque forming units (PFU), based on the overall means of all laboratory results. The First International Standard for yellow fever vaccine, NIBSC Code 99/616, has been established as the First International Standard for yellow fever vaccine by the Expert Committee of Biological Standards of the World Health Organisation. The International Standard has been arbitrarily assigned a potency of 10(4.5) International Units (IU) per ampoule. Manufacturers and National Control Laboratories are including the First International Standard for yellow fever vaccine in routine assays so that the minimum

  9. Debonding Stress Concentrations in a Pressurized Lobed Sandwich-Walled Generic Cryogenic Tank

    NASA Technical Reports Server (NTRS)

    Ko, William L.

    2004-01-01

    A finite-element stress analysis has been conducted on a lobed composite sandwich tank subjected to internal pressure and cryogenic cooling. The lobed geometry consists of two obtuse circular walls joined together with a common flat wall. Under internal pressure and cryogenic cooling, this type of lobed tank wall will experience open-mode (a process in which the honeycomb is stretched in the depth direction) and shear stress concentrations at the junctures where curved wall changes into flat wall (known as a curve-flat juncture). Open-mode and shear stress concentrations occur in the honeycomb core at the curve-flat junctures and could cause debonding failure. The levels of contributions from internal pressure and temperature loading to the open-mode and shear debonding failure are compared. The lobed fuel tank with honeycomb sandwich walls has been found to be a structurally unsound geometry because of very low debonding failure strengths. The debonding failure problem could be eliminated if the honeycomb core at the curve-flat juncture is replaced with a solid core.

  10. Codex Alimentarius: food quality and safety standards for international trade.

    PubMed

    Randell, A W; Whitehead, A J

    1997-08-01

    Since 1962, the Codex Alimentarius Commission (CAC) of the Food and Agriculture Organisation/World Health Organisation has been responsible for developing standards, guidelines and other recommendations on the quality and safety of food to protect the health of consumers and to ensure fair practices in food trade. The mission of the CAC remains relevant, but a number of factors have shown the need for new techniques to form the basis of food standards, the most important of which is risk analysis. The authors give a brief description of the role and work of the CAC and the efforts deployed by the Commission to respond to the challenges posed by new approaches to government regulation, harmonisation of national requirements based on international standards and the role of civil society.

  11. Halogenated Peptides as Internal Standards (H-PINS)

    PubMed Central

    Mirzaei, Hamid; Brusniak, Mi-Youn; Mueller, Lukas N.; Letarte, Simon; Watts, Julian D.; Aebersold, Ruedi

    2009-01-01

    As the application for quantitative proteomics in the life sciences has grown in recent years, so has the need for more robust and generally applicable methods for quality control and calibration. The reliability of quantitative proteomics is tightly linked to the reproducibility and stability of the analytical platforms, which are typically multicomponent (e.g. sample preparation, multistep separations, and mass spectrometry) with individual components contributing unequally to the overall system reproducibility. Variations in quantitative accuracy are thus inevitable, and quality control and calibration become essential for the assessment of the quality of the analyses themselves. Toward this end, the use of internal standards cannot only assist in the detection and removal of outlier data acquired by an irreproducible system (quality control) but can also be used for detection of changes in instruments for their subsequent performance and calibration. Here we introduce a set of halogenated peptides as internal standards. The peptides are custom designed to have properties suitable for various quality control assessments, data calibration, and normalization processes. The unique isotope distribution of halogenated peptides makes their mass spectral detection easy and unambiguous when spiked into complex peptide mixtures. In addition, they were designed to elute sequentially over an entire aqueous to organic LC gradient and to have m/z values within the commonly scanned mass range (300–1800 Da). In a series of experiments in which these peptides were spiked into an enriched N-glycosite peptide fraction (i.e. from formerly N-glycosylated intact proteins in their deglycosylated form) isolated from human plasma, we show the utility and performance of these halogenated peptides for sample preparation and LC injection quality control as well as for retention time and mass calibration. Further use of the peptides for signal intensity normalization and retention time

  12. Generalized Wall Function for Complex Turbulent Flows

    NASA Technical Reports Server (NTRS)

    Shih, Tsan-Hsing; Povinelli, Louis A.; Liu, Nan-Suey; Chen, Kuo-Huey

    2000-01-01

    A generalized wall function was proposed by Shih et al., (1999). It accounts the effect of pressure gradients on the flow near the wall. Theory shows that the effect of pressure gradients on the flow in the inertial sublayer is very significant and the standard wall function should be replaced by a generalized wall function. Since the theory is also valid for boundary layer flows toward separation, the generalized wall function may be applied to complex turbulent flows with acceleration, deceleration, separation and recirculation. This paper is to verify the generalized wall function with numerical simulations for boundary layer flows with various adverse and favorable pressure gradients, including flows about to separate. Furthermore, a general procedure of implementation of the generalized wall function for National Combustion Code (NCC) is described, it can be applied to both structured and unstructured CFD codes.

  13. Testing the internal consistency of the standard gamble in 'success' and 'failure' frames.

    PubMed

    Oliver, Adam

    2004-06-01

    Decision making behaviour has often been shown to vary following changes in the way in which choice problems are described (or 'framed'). Moreover, a number of researchers have demonstrated that the standard gamble is prone to internal inconsistency, and loss aversion has been proposed as an explanation for this observed bias. This study attempts to alter the influence of loss aversion by framing the treatment arm of the standard gamble in terms of success (where we may expect the influence of loss aversion to be relatively weak) and in terms of failure (where we may expect the influence of loss aversion to be relatively strong). The objectives of the study are (1) to test whether standard gamble values vary when structurally identical gambles are differentially framed, and (2) to test whether the standard gamble is equally prone to internal inconsistency across the two frames. The results show that compared to framing in terms of treatment success, significantly higher values were inferred when the gamble was framed in terms of treatment failure. However, there was no difference in the quite marked levels of internal inconsistency observed in both frames. It is possible that the essential construct of the standard gamble induces substantial and/or widespread loss aversion irrespective of the way in which the gamble is framed, which offers a fundamental challenge to the usefulness of this value elicitation instrument. It is therefore recommended that further tests are undertaken on more sophisticated corrective procedures designed to limit the influence of loss aversion.

  14. International Experience in Standards and Labeling Programs for Rice Cookers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Nan; Zheng, Nina

    China has had an active program on energy efficiency standards for household appliances since the mid-1990s. Rice cooker is among the first to be subject to such mandatory regulation, since it is one of the most prevalent electric appliances in Chinese households. Since first introduced in 1989, the minimum energy efficiency standard for rice cookers has not been revised. Therefore, the potential for energy saving is considerable. Initial analysis from CNIS indicates that potential carbon savings is likely to reach 7.6 million tons of CO2 by the 10th year of the standard implementation. Since September 2007, CNIS has been workingmore » with various groups to develop the new standard for rice cookers. With The Energy Foundation's support, LBNL has assisted CNIS in the revision of the minimum energy efficiency standard for rice cookers that is expected to be effective in 2009. Specifically, work has been in the following areas: assistance in developing consumer survey on usage pattern of rice cookers, review of international standards, review of international test procedures, comparison of the international standards and test procedures, and assessment of technical options of reducing energy use. This report particularly summarizes the findings of reviewing international standards and technical options of reducing energy consumption. The report consists of an overview of rice cooker standards and labeling programs and testing procedures in Hong Kong, South Korea, Japan and Thailand, and Japan's case study in developing energy efficiency rice cooker technologies and rice cooker efficiency programs. The results from the analysis can be summarized as the follows: Hong Kong has a Voluntary Energy Efficiency Labeling scheme for electric rice cookers initiated in 2001, with revision implemented in 2007; South Korea has both MEPS and Mandatory Energy Efficiency Label targeting the same category of rice cookers as Hong Kong; Thailand's voluntary endorsement labeling

  15. Disruption of cell walls for enhanced lipid recovery

    DOEpatents

    Knoshaug, Eric P; Donohoe, Bryon S; Gerken, Henri; Laurens, Lieve; Van Wychen, Stefanie Rose

    2015-03-24

    Presented herein are methods of using cell wall degrading enzymes for recovery of internal lipid bodies from biomass sources such as algae. Also provided are algal cells that express at least one exogenous gene encoding a cell wall degrading enzyme and methods for recovering lipids from the cells.

  16. International Standardization of the Clinical Dosimetry of Beta Radiation Brachytherapy Sources: Progress of an ISO Standard

    NASA Astrophysics Data System (ADS)

    Soares, Christopher

    2006-03-01

    In 2004 a new work item proposal (NWIP) was accepted by the International Organization for Standardization (ISO) Technical Committee 85 (TC85 -- Nuclear Energy), Subcommittee 2 (Radiation Protection) for the development of a standard for the clinical dosimetry of beta radiation sources used for brachytherapy. To develop this standard, a new Working Group (WG 22 - Ionizing Radiation Dosimetry and Protocols in Medical Applications) was formed. The standard is based on the work of an ad-hoc working group initiated by the Dosimetry task group of the Deutsches Insitiut für Normung (DIN). Initially the work was geared mainly towards the needs of intravascular brachytherapy, but with the decline of this application, more focus has been placed on the challenges of accurate dosimetry for the concave eye plaques used to treat ocular melanoma. Guidance is given for dosimetry formalisms, reference data to be used, calibrations, measurement methods, modeling, uncertainty determinations, treatment planning and reporting, and clinical quality control. The document is currently undergoing review by the ISO member bodies for acceptance as a Committee Draft (CD) with publication of the final standard expected by 2007. There are opportunities for other ISO standards for medical dosimetry within the framework of WG22.

  17. 77 FR 3497 - Light-Walled Rectangular Pipe and Tube From Taiwan

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-24

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-410 (Third Review)] Light-Walled... order on light-walled rectangular pipe and tube from Taiwan would be likely to lead to continuation or... views of the Commission are contained in USITC Publication 4301 (January 2012), Light-Walled Rectangular...

  18. Development Of International Data Standards For The COSMOS/PEER-LL Virtual Data Center

    NASA Astrophysics Data System (ADS)

    Swift, J. N.

    2005-12-01

    The COSMOS -PEER Lifelines Project 2L02 completed a Pilot Geotechnical Virtual Data Center (GVDC) system capable of both archiving geotechnical data and of disseminating data from multiple linked geotechnical databases. The Pilot GVDC system links geotechnical databases of four organizations: the California Geological Survey, Caltrans, PG&E, and the U. S. Geological Survey The System was presented and reviewed in the COSMOS-PEER Lifelines workshop on June 21 - 23, 2004, which was co-sponsored by the Federal Highway Administration (FHWA) and included participation by the United Kingdom Highways Agency (UKHA) , the Association of Geotechnical and Geoenvironmental Specialists in the United Kingdom (AGS), the United States Army Corp of Engineers (USACOE), Caltrans, United States Geological Survey (USGS), California Geological Survey (CGS), a number of state Departments of Transportation (DOTs), county building code officials, and representatives of academic institutions and private sector geotechnical companies. As of February 2005 COSMOS-PEER Lifelines Project 2L03 is currently funded to accomplish the following tasks: 1) expand the Pilot GVDC Geotechnical Data Dictionary and XML Schema to include data definitions and structures to describe in-situ measurements such as shear wave velocity profiles, and additional laboratory geotechnical test types; 2) participate in an international cooperative working group developing a single geotechnical data exchange standard that has broad international acceptance; and 3) upgrade the GVDC system to support corresponding exchange standard data dictionary and schema improvements. The new geophysical data structures being developed will include PS-logs, downhole geophysical logs, cross-hole velocity data, and velocity profiles derived using surface waves. A COSMOS-PEER Lifelines Geophysical Data Dictionary Working Committee constituted of experts in the development of data dictionary standards and experts in the specific data to be

  19. Recovery after abdominal wall reconstruction.

    PubMed

    Jensen, Kristian Kiim

    2017-03-01

    Incisional hernia is a common long-term complication to abdominal surgery, occurring in more than 20% of all patients. Some of these hernias become giant and affect patients in several ways. This patient group often experiences pain, decreased perceived body image, and loss of physical function, which results in a need for surgical repair of the giant hernia, known as abdominal wall reconstruction. In the current thesis, patients with a giant hernia were examined to achieve a better understanding of their physical and psychological function before and after abdominal wall reconstruction. Study I was a systematic review of the existing standardized methods for assessing quality of life after incisional hernia repair. After a systematic search in the electronic databases Embase and PubMed, a total of 26 studies using standardized measures for assessment of quality of life after incisional hernia repair were found. The most commonly used questionnaire was the generic Short-Form 36, which assesses overall health-related quality of life, addressing both physical and mental health. The second-most common questionnaire was the Carolinas Comfort Scale, which is a disease specific questionnaire addressing pain, movement limitation and mesh sensation in relation to a current or previous hernia. In total, eight different questionnaires were used at varying time points in the 26 studies. In conclusion, standardization of timing and method of quality of life assessment after incisional hernia repair was lacking. Study II was a case-control study of the effects of an enhanced recovery after surgery pathway for patients undergoing abdominal wall reconstruction for a giant hernia. Sixteen consecutive patients were included prospectively after the implementation of a new enhanced recovery after surgery pathway at the Digestive Disease Center, Bispebjerg Hospital, and compared to a control group of 16 patients included retrospectively in the period immediately prior to the

  20. Free viewpoint TV and its international standardization

    NASA Astrophysics Data System (ADS)

    Tanimoto, Masayuki

    2009-05-01

    We have developed a new type of television named FTV (Free-viewpoint TV). FTV is an innovative visual media that enables us to view a 3D scene by freely changing our viewpoints. We proposed the concept of FTV and constructed the world's first real-time system including the complete chain of operation from image capture to display. We also realized FTV on a single PC and FTV with free listening-point audio. FTV is based on the ray-space method that represents one ray in real space with one point in the ray-space. We have also developed new type of ray capture and display technologies such as a 360-degree mirror-scan ray capturing system and a 360 degree ray-reproducing display. MPEG regarded FTV as the most challenging 3D media and started the international standardization activities of FTV. The first phase of FTV is MVC (Multi-view Video Coding) and the second phase is 3DV (3D Video). MVC was completed in March 2009. 3DV is a standard that targets serving a variety of 3D displays. It will be completed within the next two years.

  1. Evidence for using Monte Carlo calculated wall attenuation and scatter correction factors for three styles of graphite-walled ion chamber.

    PubMed

    McCaffrey, J P; Mainegra-Hing, E; Kawrakow, I; Shortt, K R; Rogers, D W O

    2004-06-21

    The basic equation for establishing a 60Co air-kerma standard based on a cavity ionization chamber includes a wall correction term that corrects for the attenuation and scatter of photons in the chamber wall. For over a decade, the validity of the wall correction terms determined by extrapolation methods (K(w)K(cep)) has been strongly challenged by Monte Carlo (MC) calculation methods (K(wall)). Using the linear extrapolation method with experimental data, K(w)K(cep) was determined in this study for three different styles of primary-standard-grade graphite ionization chamber: cylindrical, spherical and plane-parallel. For measurements taken with the same 60Co source, the air-kerma rates for these three chambers, determined using extrapolated K(w)K(cep) values, differed by up to 2%. The MC code 'EGSnrc' was used to calculate the values of K(wall) for these three chambers. Use of the calculated K(wall) values gave air-kerma rates that agreed within 0.3%. The accuracy of this code was affirmed by its reliability in modelling the complex structure of the response curve obtained by rotation of the non-rotationally symmetric plane-parallel chamber. These results demonstrate that the linear extrapolation technique leads to errors in the determination of air-kerma.

  2. 25 CFR 542.4 - How do these regulations affect minimum internal control standards established in a Tribal-State...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false How do these regulations affect minimum internal control standards established in a Tribal-State compact? 542.4 Section 542.4 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.4 How do these regulations affect minimum internal...

  3. 25 CFR 542.4 - How do these regulations affect minimum internal control standards established in a Tribal-State...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 25 Indians 2 2011-04-01 2011-04-01 false How do these regulations affect minimum internal control standards established in a Tribal-State compact? 542.4 Section 542.4 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.4 How do these regulations affect minimum internal...

  4. 25 CFR 542.4 - How do these regulations affect minimum internal control standards established in a Tribal-State...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 2 2013-04-01 2013-04-01 false How do these regulations affect minimum internal control standards established in a Tribal-State compact? 542.4 Section 542.4 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.4 How do these regulations affect minimum internal...

  5. 25 CFR 542.4 - How do these regulations affect minimum internal control standards established in a Tribal-State...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 25 Indians 2 2012-04-01 2012-04-01 false How do these regulations affect minimum internal control standards established in a Tribal-State compact? 542.4 Section 542.4 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.4 How do these regulations affect minimum internal...

  6. 25 CFR 542.4 - How do these regulations affect minimum internal control standards established in a Tribal-State...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 2 2014-04-01 2014-04-01 false How do these regulations affect minimum internal control standards established in a Tribal-State compact? 542.4 Section 542.4 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.4 How do these regulations affect minimum internal...

  7. The Meaning of Curriculum-Related Examination Standards in Scotland and England: A Home-International Comparison

    ERIC Educational Resources Information Center

    Baird, Jo-Anne; Gray, Lena

    2016-01-01

    The ways in which examination standards are conceptualised and operationalised differently across nations has not been given sufficient attention. The international literature on standard-setting has been dominated by the psychometrics tradition. Broader conceptualisations of examination standards have been discussed in the literature in England,…

  8. An Experimental Study of the Internal Consistency of Judgments Made in Bookmark Standard Setting

    ERIC Educational Resources Information Center

    Clauser, Brian E.; Baldwin, Peter; Margolis, Melissa J.; Mee, Janet; Winward, Marcia

    2017-01-01

    Validating performance standards is challenging and complex. Because of the difficulties associated with collecting evidence related to external criteria, validity arguments rely heavily on evidence related to internal criteria--especially evidence that expert judgments are internally consistent. Given its importance, it is somewhat surprising…

  9. 75 FR 55269 - Minimum Internal Control Standards for Class II Gaming

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-10

    ... DEPARTMENT OF THE INTERIOR National Indian Gaming Commission 25 CFR Parts 542 and 543 RIN 3141-AA-37 Minimum Internal Control Standards for Class II Gaming AGENCY: National Indian Gaming Commission. ACTION: Delay of effective date of final rule; request for comments. SUMMARY: The National Indian Gaming...

  10. A Principles-Based Approach to Teaching International Financial Reporting Standards (IFRS)

    ERIC Educational Resources Information Center

    Persons, Obeua

    2014-01-01

    This article discusses the principles-based approach that emphasizes a "why" question by using the International Accounting Standards Board (IASB) "Conceptual Framework for Financial Reporting" to question and understand the basis for specific differences between IFRS and U.S. generally accepted accounting principles (U.S.…

  11. Implementing standardized, inter-unit communication in an international setting: handoff of patients from emergency medicine to internal medicine.

    PubMed

    Balhara, Kamna S; Peterson, Susan M; Elabd, Mohamed Moheb; Regan, Linda; Anton, Xavier; Al-Natour, Basil Ali; Hsieh, Yu-Hsiang; Scheulen, James; Stewart de Ramirez, Sarah A

    2018-04-01

    Standardized handoffs may reduce communication errors, but research on handoff in community and international settings is lacking. Our study at a community hospital in the United Arab Emirates characterizes existing handoff practices for admitted patients from emergency medicine (EM) to internal medicine (IM), develops a standardized handoff tool, and assesses its impact on communication and physician perceptions. EM physicians completed a survey regarding handoff practices and expectations. Trained observers utilized a checklist based on the Systems Engineering Initiative for Patient Safety model to observe 40 handoffs. EM and IM physicians collaboratively developed a written tool encouraging bedside handoff of admitted patients. After the intervention, surveys of EM physicians and 40 observations were subsequently repeated. 77.5% of initial observed handoffs occurred face-to-face, with 42.5% at bedside, and in four different languages. Most survey respondents considered face-to-face handoff ideal. Respondents noted 9-13 patients suffering harm due to handoff in the prior month. After handoff tool implementation, 97.5% of observed handoffs occurred face-to-face (versus 77.5%, p = 0.014), with 82.5% at bedside (versus 42.5%, p < 0.001), and all in English. Handoff was streamlined from 7 possible pathways to 3. Most post-intervention survey respondents reported improved workflow (77.8%) and safety (83.3%); none reported patient harm. Respondents and observers noted reduced inefficiency (p < 0.05). Our standardized tool increased face-to-face and bedside handoff, positively impacted workflow, and increased perceptions of safety by EM physicians in an international, non-academic setting. Our three-step approach can be applied towards developing standardized, context-specific inter-specialty handoff in a variety of settings.

  12. 25 CFR 543.14 - What are the minimum internal control standards for patron deposit accounts and cashless systems?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for patron deposit accounts and cashless systems? 543.14 Section 543.14 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.14 What are the minimum internal control...

  13. 25 CFR 543.12 - What are the minimum internal control standards for gaming promotions and player tracking systems?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for gaming promotions and player tracking systems? 543.12 Section 543.12 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.12 What are the minimum internal contro...

  14. 25 CFR 543.14 - What are the minimum internal control standards for patron deposit accounts and cashless systems?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for patron deposit accounts and cashless systems? 543.14 Section 543.14 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.14 What are the minimum internal control...

  15. 25 CFR 543.12 - What are the minimum internal control standards for gaming promotions and player tracking systems?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for gaming promotions and player tracking systems? 543.12 Section 543.12 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.12 What are the minimum internal contro...

  16. Moisture Management for High R-Value Walls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lepage, R.; Schumacher, C.; Lukachko, A.

    2013-11-01

    This report explains the moisture-related concerns for high R-value wall assemblies and discusses past Building America research work that informs this study. In this project, hygrothermal simulations were prepared for several common approaches to High R-value wall construction in six cities (Houston, Atlanta, Seattle, St. Louis, Chicago, and International Falls) representing a range of climate zones. The modeling program assessed the moisture durability of the wall assemblies based on three primary sources of moisture: construction moisture, air leakage condensation, and bulk water leakage; the report presents results of the study.

  17. International standards for tuberculosis care: relevance and implications for laboratory professionals.

    PubMed

    Pai, M; Daley, P; Hopewell, P C

    2007-04-01

    On World Tuberculosis (TB) Day 2006, the International Standards for Tuberculosis Care (ISTC) was officially released and widely endorsed by several agencies and organizations. The ISTC release was the culmination of a year long global effort to develop and set internationally acceptable, evidence-based standards for tuberculosis care. The ISTC describes a widely endorsed level of care that all practitioners, public and private, should seek to achieve in managing individuals who have or are suspected of having, TB and is intended to facilitate the effective engagement of all healthcare providers in delivering high quality care for patients of all ages, including those with smear-positive, smear-negative and extra-pulmonary TB, TB caused by drug-resistant Mycobacterium tuberculosis and TB/HIV coinfection. In this article, we present the ISTC, with a special focus on the diagnostic standards and describe their implications and relevance for laboratory professionals in India and worldwide. Laboratory professionals play a critical role in ensuring that all the standards are actually met by providing high quality laboratory services for smear microscopy, culture and drug susceptibility testing and other services such as testing for HIV infection. In fact, if the ISTC is widely followed, it can be expected that there will be a greater need and demand for quality assured laboratory services and this will have obvious implications for all laboratories in terms of work load, requirement for resources and trained personnel and organization of quality assurance systems.

  18. International standards: the World Organisation for Animal Health Terrestrial Animal Health Code.

    PubMed

    Thiermann, A B

    2015-04-01

    This paper provides a description of the international standards contained in the TerrestrialAnimal Health Code of the World Organisation for Animal Health (OIE) that relate to the prevention and control of vector-borne diseases. It identifies the rights and obligations of OIE Member Countries regarding the notification of animal disease occurrences, as well as the recommendations to be followed for a safe and efficient international trade of animals and their products.

  19. 76 FR 62961 - Lifesaving Equipment: Production Testing and Harmonization With International Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-11

    ... CFR Parts 108, 117, et al. Lifesaving Equipment: Production Testing and Harmonization With... Equipment: Production Testing and Harmonization With International Standards AGENCY: Coast Guard, DHS... equipment, including launching appliances (winches and davits), release mechanisms, survival craft...

  20. India Needs International Standards in Accreditation Problems in Adoption and Implementation

    ERIC Educational Resources Information Center

    Naik, B. M.

    2012-01-01

    The paper outlines in brief, need and importance of introducing global quality standards in accreditation, prescribed by the international agreement "Washington Accord". This agreement is initially provisional and after scrutiny, if found fit, it is upgraded to Signatory status. It is this status which empowers students of engineering,…

  1. Concept of Draft International Standard for a Unified Approach to Space Program Quality Assurance

    NASA Astrophysics Data System (ADS)

    Stryzhak, Y.; Vasilina, V.; Kurbatov, V.

    2002-01-01

    For want of the unified approach to guaranteed space project and product quality assurance, implementation of many international space programs has become a challenge. Globalization of aerospace industry and participation of various international ventures with diverse quality assurance requirements in big international space programs requires for urgent generation of unified international standards related to this field. To ensure successful fulfillment of space missions, aerospace companies should design and process reliable and safe products with properties complying or bettering User's (or Customer's) requirements. Quality of the products designed or processed by subcontractors (or other suppliers) should also be in compliance with the main user (customer)'s requirements. Implementation of this involved set of unified requirements will be made possible by creating and approving a system (series) of international standards under a generic title Space Product Quality Assurance based on a system consensus principle. Conceptual features of the baseline standard in this system (series) should comprise: - Procedures for ISO 9000, CEN and ECSS requirements adaptation and introduction into space product creation, design, manufacture, testing and operation; - Procedures for quality assurance at initial (design) phases of space programs, with a decision on the end product made based on the principle of independence; - Procedures to arrange incoming inspection of products delivered by subcontractors (including testing, audit of supplier's procedures, review of supplier's documentation), and space product certification; - Procedures to identify materials and primary products applied; - Procedures for quality system audit at the component part, primary product and materials supplier facilities; - Unified procedures to form a list of basic performances to be under configuration management; - Unified procedures to form a list of critical space product components, and unified

  2. Preparation and application of in-fibre internal standardization solid-phase microextraction.

    PubMed

    Zhao, Wennan; Ouyang, Gangfeng; Pawliszyn, Janusz

    2007-03-01

    The in-fibre standardization method is a novel approach that has been developed for field sampling/sample preparation, in which an internal standard is pre-loaded onto a solid-phase microextraction (SPME) fibre for calibration of the extraction of target analytes in field samples. The same method can also be used for in-vial sample analysis. In this study, different techniques to load the standard to a non-porous SPME fibre were investigated. It was found that the appropriateness of the technique depends on the physical properties of the standards that are used for the analysis. Headspace extraction of the standard dissolved in pumping oil works well for volatile compounds. Conversely, headspace extraction of the pure standard is an effective approach for semi-volatile compounds. For compounds with low volatility, a syringe-fibre transfer method and direct extraction of the standard dissolved in a solvent exhibited a good reproducibility (<5% RSD). The main advantage of the approaches investigated in this study is that the standard generation vials can be reused for hundreds of analyses without exhibiting significant loss. Moreover, most of the standard loading processes studied can be performed automatically, which is efficient and precise. Finally, the standard loading technique and in-fibre standardization method were applied to a complex matrix (milk) and the results illustrated that the matrix effect can be effectively compensated for with this approach.

  3. Seismic Response Of Masonry Plane Walls: A Numerical Study On Spandrel Strength

    NASA Astrophysics Data System (ADS)

    Betti, Michele; Galano, Luciano; Vignoli, Andrea

    2008-07-01

    The paper reports the results of a numerical investigation on masonry walls subjected to in-plane seismic loads. This research aims to verify the formulae of shear and flexural strength of masonry spandrels which are given in the recent Italian Standards [1]. Seismic pushover analyses have been carried out using finite element models of unreinforced walls and strengthened walls introducing reinforced concrete (RC) beams at the floor levels. Two typologies of walls have been considered distinguished for the height to length ratio h/l of the spandrels: a) short beams (h/l = 1.33) and b) slender beams (h/l = 0.5). Results obtained for the unreinforced and the strengthened walls are compared with equations for shear and flexural strength provided in Standards [1]. The numerical analyses show that the reliability of these equations is at least questionable especially for the prediction of the flexural strength. In the cases in which the axial force has not been determined by the structural analysis, Standards [1] seems to overestimate the flexural strength of short spandrels both for the unreinforced and the strengthened wall.

  4. 76 FR 64105 - Light-Walled Rectangular Pipe From Taiwan; Scheduling of an Expedited Five-Year Review Concerning...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-17

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-410 (Third Review)] Light-Walled... Order on Light-Walled Rectangular Pipe From Taiwan AGENCY: United States International Trade Commission... determine whether revocation of the antidumping duty order on light-walled rectangular pipe from Taiwan...

  5. International Standards on stability of digital prints

    NASA Astrophysics Data System (ADS)

    Adelstein, Peter Z.

    2010-06-01

    The International Standards Organization (ISO) is a worldwide recognized standardizing body which has responsibility for standards on permanence of digital prints. This paper is an update on the progress made to date by ISO in writing test methods in this area. Three technologies are involved, namely ink jet, dye diffusion thermal transfer (dye-sublimation) and electrophotography. Two types of test methods are possible, namely comparative tests and predictive tests. To date a comparative test on water fastness has been published and final balloting is underway on a comparative test on humidity fastness. Predictive tests are being finalized on thermal stability and pollution susceptibility. The test method on thermal stability is intended to predict the print life during normal aging. One of the testing concerns is that some prints do not show significant image change in practical testing times. The test method on pollution susceptibility only deals with ozone and assumes that the reciprocity law applies. This law assumes that a long time under a low pollutant concentration is equivalent to a short time under the high concentration used in the test procedure. Longer term studies include a predictive test for light stability and the preparation of a material specification. The latter requires a decision about the proper colour target to be used and what constitutes an unacceptable colour change. Moreover, a specification which gives a predictive life is very dependent upon the conditions the print encounters and will only apply to specific levels of temperature, ozone and light.

  6. Weighing in on international growth standards: testing the case in Australian preschool children.

    PubMed

    Pattinson, C L; Staton, S L; Smith, S S; Trost, S G; Sawyer, E F; Thorpe, K J

    2017-10-01

    Overweight and obesity in preschool-aged children are major health concerns. Accurate and reliable estimates of prevalence are necessary to direct public health and clinical interventions. There are currently three international growth standards used to determine prevalence of overweight and obesity, each using different methodologies: Center for Disease Control (CDC), World Health Organization (WHO) and International Obesity Task Force (IOTF). Adoption and use of each method were examined through a systematic review of Australian population studies (2006-2017). For this period, systematically identified population studies (N = 20) reported prevalence of overweight and obesity ranging between 15 and 38% with most (n = 16) applying the IOTF standards. To demonstrate the differences in prevalence estimates yielded by the IOTF in comparison to the WHO and CDC standards, methods were applied to a sample of N = 1,926 Australian children, aged 3-5 years. As expected, the three standards yielded significantly different estimates when applied to this single population. Prevalence of overweight/obesity was WHO - 9.3%, IOTF - 21.7% and CDC - 33.1%. Judicious selection of growth standards, taking account of their underpinning methodologies and provisions of access to study data sets to allow prevalence comparisons, is recommended. © 2017 World Obesity Federation.

  7. The pluralization of the international: Resistance and alter-standardization in regenerative stem cell medicine

    PubMed Central

    Rosemann, Achim; Chaisinthop, Nattaka

    2016-01-01

    The article explores the formation of an international politics of resistance and ‘alter-standardization’ in regenerative stem cell medicine. The absence of internationally harmonized regulatory frameworks in the clinical stem cell field and the presence of lucrative business opportunities have resulted in the formation of transnational networks adopting alternative research standards and practices. These oppose, as a universal global standard, strict evidence-based medicine clinical research protocols as defined by scientists and regulatory agencies in highly developed countries. The emergence of transnational spaces of alter-standardization is closely linked to scientific advances in rapidly developing countries such as China and India, but calls for more flexible regulatory frameworks, and the legitimization of experimental for-profit applications outside of evidence-based medical care, are emerging increasingly also within more stringently regulated countries, such as the United States and countries in the European Union. We can observe, then, a trend toward the pluralization of the standards, practices, and concepts in the stem cell field. PMID:26983174

  8. Determination of strength behaviour of slope supported by vegetated crib walls using centrifuge model testing

    NASA Astrophysics Data System (ADS)

    Sudan Acharya, Madhu

    2010-05-01

    The crib retaining structures made of wooden/bamboo logs with live plants inside are called vegetative crib walls which are now becoming popular due to their advantages over conventional civil engineering walls. Conventionally, wooden crib walls were dimensioned based on past experiences. At present, there are several guidelines and design standards for machine finished wooden crib walls, but only few guidelines for the design and construction of vegetative log crib walls are available which are generally not sufficient for an economic engineering design of such walls. Analytical methods are generally used to determine the strength of vegetated crib retaining walls. The crib construction is analysed statically by satisfying the condition of static equilibrium with acceptable level of safety. The crib wall system is checked for internal and external stability using conventional monolithic and silo theories. Due to limitations of available theories, the exact calculation of the strength of vegetated wooden/bamboo crib wall cannot be made in static calculation. Therefore, experimental measurements are generally done to verify the static analysis. In this work, a model crib construction (1:20) made of bamboo elements is tested in the centrifuge machine to determine the strength behaviour of the slope supported by vegetated crib retaining wall. A geotechnical centrifuge is used to conduct model tests to study geotechnical problems such as the strength, stiffness and bearing capacity of different structures, settlement of embankments, stability of slopes, earth retaining structures etc. Centrifuge model testing is particularly well suited to modelling geotechnical events because the increase in gravitational force creates stresses in the model that are equivalent to the much larger prototype and hence ensures that the mechanisms of ground movements observed in the tests are realistic. Centrifuge model testing provides data to improve our understanding of basic mechanisms

  9. 78 FR 52532 - Exposure Draft-Standards for Internal Control in the Federal Government

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-23

    ... developments in the accountability and financial management profession and emphasize specific considerations applicable to the government environment. The draft of the proposed changes to Standards for Internal Control...

  10. Integrated Procedures for Flight and Ground Operations Using International Standards

    NASA Technical Reports Server (NTRS)

    Ingalls, John

    2011-01-01

    Imagine astronauts using the same Interactive Electronic Technical Manuals (IETM's) as the ground personnel who assemble or maintain their flight hardware, and having all of that data interoperable with design, logistics, reliability analysis, and training. Modern international standards and their corresponding COTS tools already used in other industries provide a good foundation for streamlined technical publications in the space industry. These standards cover everything from data exchange to product breakdown structure to business rules flexibility. Full Product Lifecycle Support (PLCS) is supported. The concept is to organize, build once, reuse many ways, and integrate. This should apply to all future and some current launch vehicles, payloads, space stations/habitats, spacecraft, facilities, support equipment, and retrieval ships.

  11. International Labour Standards and Technical Co-Operation: The Case of Special Public Works Programmes.

    ERIC Educational Resources Information Center

    Mayer, Jean

    1989-01-01

    Applies international labor standards to results of the International Labour Office's special public works programs to discover whether program intentions have been met. Finds that while productive employment has been pursued, popular participation is not occurring and such issues as (1) forced labor, (2) child employment, and (3) inequality of…

  12. Rabies vaccine standards: comparison of the 5th and 6th WHO international reference standards to the USDA veterinary reference standard.

    PubMed

    Hermann, J; Fry, A; Reising, M; Patterson, P; Siev, D; Gatewood, D

    2012-11-06

    Ensuring rabies vaccines are potent and effective is paramount in preventing transmission of this deadly disease and safeguarding public health. Efficacy of human and veterinary vaccines is ensured by evaluating relative potency estimates of the vaccine compared to a rabies reference standard using the National Institutes of Health (NIH) test. Reference vaccines are based on the International Standard for Rabies Vaccine provided by the World Health Organization (WHO). A comparison study was conducted to determine the relative potency of the 5th WHO, 6th WHO, and United States Department of Agriculture's (USDA) 08-14 reference standards using the NIH test. Results from the study demonstrate that the 6th WHO reference standard is approximately twice as potent as the 5th WHO reference when reconstituted to contain 1 IU per ml. Based on these results, the Center for Veterinary Biologics (CVB) doubled the reconstitution volume of USDA veterinary reference 08-14 from 13 ml to 26 ml, for an initial use dilution of 0.7 IU per ml for use by veterinary biologics manufacturers in the NIH test. This study emphasizes the importance of reference standard calibration for use in the National Institutes of Health test. Published by Elsevier Ltd.

  13. Halogenated peptides as internal standards (H-PINS): introduction of an MS-based internal standard set for liquid chromatography-mass spectrometry.

    PubMed

    Mirzaei, Hamid; Brusniak, Mi-Youn; Mueller, Lukas N; Letarte, Simon; Watts, Julian D; Aebersold, Ruedi

    2009-08-01

    As the application for quantitative proteomics in the life sciences has grown in recent years, so has the need for more robust and generally applicable methods for quality control and calibration. The reliability of quantitative proteomics is tightly linked to the reproducibility and stability of the analytical platforms, which are typically multicomponent (e.g. sample preparation, multistep separations, and mass spectrometry) with individual components contributing unequally to the overall system reproducibility. Variations in quantitative accuracy are thus inevitable, and quality control and calibration become essential for the assessment of the quality of the analyses themselves. Toward this end, the use of internal standards cannot only assist in the detection and removal of outlier data acquired by an irreproducible system (quality control) but can also be used for detection of changes in instruments for their subsequent performance and calibration. Here we introduce a set of halogenated peptides as internal standards. The peptides are custom designed to have properties suitable for various quality control assessments, data calibration, and normalization processes. The unique isotope distribution of halogenated peptides makes their mass spectral detection easy and unambiguous when spiked into complex peptide mixtures. In addition, they were designed to elute sequentially over an entire aqueous to organic LC gradient and to have m/z values within the commonly scanned mass range (300-1800 Da). In a series of experiments in which these peptides were spiked into an enriched N-glycosite peptide fraction (i.e. from formerly N-glycosylated intact proteins in their deglycosylated form) isolated from human plasma, we show the utility and performance of these halogenated peptides for sample preparation and LC injection quality control as well as for retention time and mass calibration. Further use of the peptides for signal intensity normalization and retention time

  14. Using ASBO International's Standards To Map Your Professional Growth and Development Plan.

    ERIC Educational Resources Information Center

    Stratton, Susan

    2002-01-01

    Explores various definitions of what constitutes a profession and what characteristics determine a professional. Identifies the need for continued professional growth and development related to the new Association of School Business Officials, International, "Professional Standards" (2001). Examples illustrate how individual school…

  15. Estimation of bladder wall location in ultrasound images.

    PubMed

    Topper, A K; Jernigan, M E

    1991-05-01

    A method of automatically estimating the location of the bladder wall in ultrasound images is proposed. Obtaining this estimate is intended to be the first stage in the development of an automatic bladder volume calculation system. The first step in the bladder wall estimation scheme involves globally processing the images using standard image processing techniques to highlight the bladder wall. Separate processing sequences are required to highlight the anterior bladder wall and the posterior bladder wall. The sequence to highlight the anterior bladder wall involves Gaussian smoothing and second differencing followed by zero-crossing detection. Median filtering followed by thresholding and gradient detection is used to highlight as much of the rest of the bladder wall as was visible in the original images. Then a 'bladder wall follower'--a line follower with rules based on the characteristics of ultrasound imaging and the anatomy involved--is applied to the processed images to estimate the bladder wall location by following the portions of the bladder wall which are highlighted and filling in the missing segments. The results achieved using this scheme are presented.

  16. ASTM international workshop on standards and measurements for tissue engineering scaffolds.

    PubMed

    Simon, Carl G; Yaszemski, Michael J; Ratcliffe, Anthony; Tomlins, Paul; Luginbuehl, Reto; Tesk, John A

    2015-07-01

    The "Workshop on Standards & Measurements for Tissue Engineering Scaffolds" was held on May 21, 2013 in Indianapolis, IN, and was sponsored by the ASTM International (ASTM). The purpose of the workshop was to identify the highest priority items for future standards work for scaffolds used in the development and manufacture of tissue engineered medical products (TEMPs). Eighteen speakers and 78 attendees met to assess current scaffold standards and to prioritize needs for future standards. A key finding was that the ASTM TEMPs subcommittees (F04.41-46) have many active "guide" documents for educational purposes, but few standard "test methods" or "practices." Overwhelmingly, the most clearly identified need was standards for measuring the structure of scaffolds, followed by standards for biological characterization, including in vitro testing, animal models and cell-material interactions. The third most pressing need was to develop standards for assessing the mechanical properties of scaffolds. Additional needs included standards for assessing scaffold degradation, clinical outcomes with scaffolds, effects of sterilization on scaffolds, scaffold composition, and drug release from scaffolds. Discussions highlighted the need for additional scaffold reference materials and the need to use them for measurement traceability. Workshop participants emphasized the need to promote the use of standards in scaffold fabrication, characterization, and commercialization. Finally, participants noted that standards would be more broadly accepted if their impact in the TEMPs community could be quantified. Many scaffold standard needs have been identified and focus is turning to generating these standards to support the use of scaffolds in TEMPs. © 2014 Wiley Periodicals, Inc.

  17. Defining the Core Archive Data Standards of the International Planetary Data Alliance (IPDA)

    NASA Technical Reports Server (NTRS)

    Hughes, J. Steven; Crichton, Dan; Beebe, Reta; Guinness, Ed; Heather, David; Zender, Joe

    2007-01-01

    A goal of the International Planetary Data Alliance (lPDA) is to develop a set of archive data standards that enable the sharing of scientific data across international agencies and missions. To help achieve this goal, the IPDA steering committee initiated a six month proj ect to write requirements for and draft an information model based on the Planetary Data System (PDS) archive data standards. The project had a special emphasis on data formats. A set of use case scenarios were first developed from which a set of requirements were derived for the IPDA archive data standards. The special emphasis on data formats was addressed by identifying data formats that have been used by PDS nodes and other agencies in the creation of successful data sets for the Planetary Data System (PDS). The dependency of the IPDA information model on the PDS archive standards required the compilation of a formal specification of the archive standards currently in use by the PDS. An ontology modelling tool was chosen to capture the information model from various sources including the Planetary Science Data Dictionary [I] and the PDS Standards Reference [2]. Exports of the modelling information from the tool database were used to produce the information model document using an object-oriented notation for presenting the model. The tool exports can also be used for software development and are directly accessible by semantic web applications.

  18. ICA contribution to the development of international standards of competence for nautical cartographers

    NASA Astrophysics Data System (ADS)

    Furness, Ron; Tsoulos, Lysandros

    2018-05-01

    All professions face challenges as how best to ensure the achievement and continuance of the highest standards as they seek to determine and promulgate best practices. In the essentially linked professions of hydrographic surveying and nautical cartography these challenges become immediately international in their impacts and require close cooperation between the professional bodies representing surveyors, hydrographers and cartographers. The Standards of Competence for Nautical Cartographers are known in short form as S-8 and they describe the minimum required competencies for nautical cartographers. They indicate the minimum degree of knowledge and experience considered necessary for nautical cartographers and provide a set of programme outlines against which the FIG/IHO/ICA International Board on Standards of Competence for Hydrographic Surveyors and Nautical Cartographers may evaluate programmes submitted for recognition. The Standards recognize two levels of competence: Cate- gory A and Category B. In nautical charting communities, Category A programmes offer levels of comprehensive and broad-based knowledge in all aspects of the theory and practice of nautical cartography. Category B programmes provide a level of practical comprehension, along with the essential theoretical background, necessary for individuals to carry out the various nautical cartography tasks. The Standards have recently undergone complete review and should be ratified during 2017/18. This paper aims to bring the existence and aims of the Standards to the wider notice of ICA members and to describe the philosophy and aims of the review in meeting the professional competency needs of the nautical cartographic community.

  19. Interpreting international governance standards for health IT use within general medical practice.

    PubMed

    Mahncke, Rachel J; Williams, Patricia A H

    2014-01-01

    General practices in Australia recognise the importance of comprehensive protective security measures. Some elements of information security governance are incorporated into recommended standards, however the governance component of information security is still insufficiently addressed in practice. The International Organistion for Standardisation (ISO) released a new global standard in May 2013 entitled, ISO/IEC 27014:2013 Information technology - Security techniques - Governance of information security. This standard, applicable to organisations of all sizes, offers a framework against which to assess and implement the governance components of information security. The standard demonstrates the relationship between governance and the management of information security, provides strategic principles and processes, and forms the basis for establishing a positive information security culture. An analysis interpretation of this standard for use in Australian general practice was performed. This work is unique as such interpretation for the Australian healthcare environment has not been undertaken before. It demonstrates an application of the standard at a strategic level to inform existing development of an information security governance framework.

  20. Translating Radiometric Requirements for Satellite Sensors to Match International Standards.

    PubMed

    Pearlman, Aaron; Datla, Raju; Kacker, Raghu; Cao, Changyong

    2014-01-01

    International scientific standards organizations created standards on evaluating uncertainty in the early 1990s. Although scientists from many fields use these standards, they are not consistently implemented in the remote sensing community, where traditional error analysis framework persists. For a satellite instrument under development, this can create confusion in showing whether requirements are met. We aim to create a methodology for translating requirements from the error analysis framework to the modern uncertainty approach using the product level requirements of the Advanced Baseline Imager (ABI) that will fly on the Geostationary Operational Environmental Satellite R-Series (GOES-R). In this paper we prescribe a method to combine several measurement performance requirements, written using a traditional error analysis framework, into a single specification using the propagation of uncertainties formula. By using this approach, scientists can communicate requirements in a consistent uncertainty framework leading to uniform interpretation throughout the development and operation of any satellite instrument.

  1. Translating Radiometric Requirements for Satellite Sensors to Match International Standards

    PubMed Central

    Pearlman, Aaron; Datla, Raju; Kacker, Raghu; Cao, Changyong

    2014-01-01

    International scientific standards organizations created standards on evaluating uncertainty in the early 1990s. Although scientists from many fields use these standards, they are not consistently implemented in the remote sensing community, where traditional error analysis framework persists. For a satellite instrument under development, this can create confusion in showing whether requirements are met. We aim to create a methodology for translating requirements from the error analysis framework to the modern uncertainty approach using the product level requirements of the Advanced Baseline Imager (ABI) that will fly on the Geostationary Operational Environmental Satellite R-Series (GOES-R). In this paper we prescribe a method to combine several measurement performance requirements, written using a traditional error analysis framework, into a single specification using the propagation of uncertainties formula. By using this approach, scientists can communicate requirements in a consistent uncertainty framework leading to uniform interpretation throughout the development and operation of any satellite instrument. PMID:26601032

  2. Upcoming new international measurement standards in the field of building acoustics

    NASA Astrophysics Data System (ADS)

    Goydke, Hans

    2002-11-01

    The extensively completed revision of most of the ISO measurement standards in building acoustics mainly initiated by the European Commissions demand for harmonized standards emphasized the insight that the main goal to avoid trade barriers between the countries can only be reached when the standards sufficiently and comprehensively cover the field when they are related to the actual state of the art and when they are sufficiently related to practice. In modern architecture one can observe the rapid change in the use of building materials, for instance regarding the use of glass. Lightweight constructions as well as heavyweight building elements with additional linings are increasingly in common use and unquestionably there are consequences to be considered regarding the ascertainment of sound insulation properties. Besides others, International Standardization is unsatisfactory regarding the assessment of noise in buildings from waste water installations, in the low frequency area and in general regarding the expression of uncertainty of measurements. Intensity measurements in building acoustics, rainfall noise assessment, estimation of sound insulation, impulse response measurement methods, assessment of sound scattering are examples of upcoming standards.

  3. International Symposium on Information Technology: Standards for Bibliographic Control (Bangkok, Thailand, September 4-8, 1989).

    ERIC Educational Resources Information Center

    Thammasat Univ., Bangkok (Thailand). Univ. Libraries.

    This document which covers the proceedings of the 1989 International Symposium on Information Technology, begins with several opening ceremony messages and includes the following papers: (1) "Reflections on International Bibliographic Standards" (Winston D. Roberts); (2) "Bibliographic Control from the User's Perspective" (Ruth…

  4. 40 CFR 60.4231 - What emission standards must I meet if I am a manufacturer of stationary SI internal combustion...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... I am a manufacturer of stationary SI internal combustion engines or equipment containing such... Stationary Spark Ignition Internal Combustion Engines Emission Standards for Manufacturers § 60.4231 What emission standards must I meet if I am a manufacturer of stationary SI internal combustion engines or...

  5. 40 CFR 60.4231 - What emission standards must I meet if I am a manufacturer of stationary SI internal combustion...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... I am a manufacturer of stationary SI internal combustion engines or equipment containing such... Stationary Spark Ignition Internal Combustion Engines Emission Standards for Manufacturers § 60.4231 What emission standards must I meet if I am a manufacturer of stationary SI internal combustion engines or...

  6. 40 CFR 60.4231 - What emission standards must I meet if I am a manufacturer of stationary SI internal combustion...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... I am a manufacturer of stationary SI internal combustion engines or equipment containing such... Stationary Spark Ignition Internal Combustion Engines Emission Standards for Manufacturers § 60.4231 What emission standards must I meet if I am a manufacturer of stationary SI internal combustion engines or...

  7. 40 CFR 60.4231 - What emission standards must I meet if I am a manufacturer of stationary SI internal combustion...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... I am a manufacturer of stationary SI internal combustion engines or equipment containing such... Stationary Spark Ignition Internal Combustion Engines Emission Standards for Manufacturers § 60.4231 What emission standards must I meet if I am a manufacturer of stationary SI internal combustion engines or...

  8. 40 CFR 60.4231 - What emission standards must I meet if I am a manufacturer of stationary SI internal combustion...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... I am a manufacturer of stationary SI internal combustion engines or equipment containing such... Stationary Spark Ignition Internal Combustion Engines Emission Standards for Manufacturers § 60.4231 What emission standards must I meet if I am a manufacturer of stationary SI internal combustion engines or...

  9. Seismic Response Of Masonry Plane Walls: A Numerical Study On Spandrel Strength

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Betti, Michele; Galano, Luciano; Vignoli, Andrea

    2008-07-08

    The paper reports the results of a numerical investigation on masonry walls subjected to in-plane seismic loads. This research aims to verify the formulae of shear and flexural strength of masonry spandrels which are given in the recent Italian Standards. Seismic pushover analyses have been carried out using finite element models of unreinforced walls and strengthened walls introducing reinforced concrete (RC) beams at the floor levels. Two typologies of walls have been considered distinguished for the height to length ratio h/l of the spandrels: a) short beams (h/l = 1.33) and b) slender beams (h/l = 0.5). Results obtained formore » the unreinforced and the strengthened walls are compared with equations for shear and flexural strength provided in Standards [1]. The numerical analyses show that the reliability of these equations is at least questionable especially for the prediction of the flexural strength. In the cases in which the axial force has not been determined by the structural analysis, Standards seems to overestimate the flexural strength of short spandrels both for the unreinforced and the strengthened wall.« less

  10. Establishment of the first international standard for PEGylated granulocyte colony stimulating factor (PEG-G-CSF): Report of an international collaborative study

    PubMed Central

    Wadhwa, Meenu; Bird, Chris; Dougall, Thomas; Rigsby, Peter; Bristow, Adrian; Thorpe, Robin

    2015-01-01

    We assessed the feasibility of developing a suitable international reference standard for determination of in vitro biological activity of human sequence recombinant PEG-G-CSF products with a 20 kD linear PEG linked to the N-terminal methionyl residue of G-CSF (INN Filgrastim), produced using a conjugation process and coupling chemistry similar to that employed for the lead PEGfilgrastim product. Based on initial data which showed that the current WHO 2nd international standard, IS for G-CSF (09/136) or alternatively, a PEG-G-CSF standard with a unitage traceable to the G-CSF IS may potentially serve as the IS for PEG-G-CSF products, two candidate preparations of PEG-G-CSF were formulated and lyophilized at NIBSC. These preparations were tested by 23 laboratories using in vitro bioassays in a multi-centre collaborative study. Results indicated that on the basis of parallelism, the current WHO 2nd IS for G-CSF or any of the PEG-G-CSF samples could be used as the international standard for PEG-G-CSF preparations. However, because of the variability in potency estimates seen when PEG-G-CSF preparations were compared with the current WHO 2nd IS for G-CSF, a candidate PEG-G-CSF was suitable as the WHO IS. The preparation 12/188 was judged suitable to serve as the WHO IS based on in vitro biological activity data. Therefore, the preparation coded 12/188 was established by the WHO Expert Committee on Biological Standardization (ECBS) in 2013 as the WHO 1st IS for human PEGylated G-CSF with an assigned in vitro bioactivity of 10,000 IU per ampoule. PMID:25450254

  11. A change of course: The importance to DoD of international standards for electronic commerce

    NASA Astrophysics Data System (ADS)

    Payne, Judith E.

    1991-12-01

    The U.S. Department of Defense (DoD) is committed to using electronic commerce in the future with the over 300,000 vendors interested in doing business with DoD. Electronic commerce will move DoD from a paper-based world to one based on electronic transactions enabled by the exchange of formatted, electronic messages referred to as electronic data interchange (EDI). With electronic commerce, DoD plans to reduce costs, increase effectiveness, and make it easier for vendors to deal with DoD. Benefits from electronic commerce are enhanced when many businesses use the same standards for EDI messages themselves and their transmission. The fewer standards used, the less time and resources must be spent translating messages and agreeing on how to use different standards. To enhance benefits and smooth the transition to electronic commerce for itself and its vendors, DoD has chosen to use the widely accepted American National Standards Institute (ANSI) X12 standards for EDI messages, coupled with international standards for delivering messages and organizing addresses. In the past 18 months, EDI standards sponsored by a United Nations body and serving the same purpose as ANSI X12 message standards have begun to gain wider acceptance internationally.

  12. The Utilization of Plant Facilities on the International Space Station—The Composition, Growth, and Development of Plant Cell Walls under Microgravity Conditions

    PubMed Central

    Jost, Ann-Iren Kittang; Hoson, Takayuki; Iversen, Tor-Henning

    2015-01-01

    In the preparation for missions to Mars, basic knowledge of the mechanisms of growth and development of living plants under microgravity (micro-g) conditions is essential. Focus has centered on the g-effects on rigidity, including mechanisms of signal perception, transduction, and response in gravity resistance. These components of gravity resistance are linked to the evolution and acquisition of responses to various mechanical stresses. An overview is given both on the basic effect of hypergravity as well as of micro-g conditions in the cell wall changes. The review includes plant experiments in the US Space Shuttle and the effect of short space stays (8–14 days) on single cells (plant protoplasts). Regeneration of protoplasts is dependent on cortical microtubules to orient the nascent cellulose microfibrils in the cell wall. The space protoplast experiments demonstrated that the regeneration capacity of protoplasts was retarded. Two critical factors are the basis for longer space experiments: a. the effects of gravity on the molecular mechanisms for cell wall development, b. the availability of facilities and hardware for performing cell wall experiments in space and return of RNA/DNA back to the Earth. Linked to these aspects is a description of existing hardware functioning on the International Space Station. PMID:27135317

  13. The Utilization of Plant Facilities on the International Space Station-The Composition, Growth, and Development of Plant Cell Walls under Microgravity Conditions.

    PubMed

    Jost, Ann-Iren Kittang; Hoson, Takayuki; Iversen, Tor-Henning

    2015-01-20

    In the preparation for missions to Mars, basic knowledge of the mechanisms of growth and development of living plants under microgravity (micro-g) conditions is essential. Focus has centered on the g-effects on rigidity, including mechanisms of signal perception, transduction, and response in gravity resistance. These components of gravity resistance are linked to the evolution and acquisition of responses to various mechanical stresses. An overview is given both on the basic effect of hypergravity as well as of micro-g conditions in the cell wall changes. The review includes plant experiments in the US Space Shuttle and the effect of short space stays (8-14 days) on single cells (plant protoplasts). Regeneration of protoplasts is dependent on cortical microtubules to orient the nascent cellulose microfibrils in the cell wall. The space protoplast experiments demonstrated that the regeneration capacity of protoplasts was retarded. Two critical factors are the basis for longer space experiments: a. the effects of gravity on the molecular mechanisms for cell wall development, b. the availability of facilities and hardware for performing cell wall experiments in space and return of RNA/DNA back to the Earth. Linked to these aspects is a description of existing hardware functioning on the International Space Station.

  14. 75 FR 53457 - Lifesaving Equipment: Production Testing and Harmonization With International Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-31

    ... approval process for all lifesaving equipment required under the various vessel and facility regulations in... buoyant apparatuses. If the proposed rule is made final, all equipment approved after the effective date... Equipment: Production Testing and Harmonization With International Standards; Proposed Rule #0;#0;Federal...

  15. Failure Behavior of Elbows with Local Wall Thinning

    NASA Astrophysics Data System (ADS)

    Lee, Sung-Ho; Lee, Jeong-Keun; Park, Jai-Hak

    Wall thinning defect due to corrosion is one of major aging phenomena in carbon steel pipes in most plant industries, and it results in reducing load carrying capacity of the piping components. A failure test system was set up for real scale elbows containing various simulated wall thinning defects, and monotonic in-plane bending tests were performed under internal pressure to find out the failure behavior of them. The failure behavior of wall-thinned elbows was characterized by the circumferential angle of thinned region and the loading conditions to the piping system.

  16. Use of Joint Commission International Standards to Evaluate and Improve Pediatric Oncology Nursing Care in Guatemala

    PubMed Central

    Day, Sara W.; McKeon, Leslie M.; Garcia, Jose; Wilimas, Judith A.; Carty, Rita M.; de Alarcon, Pedro; Antillon, Federico; Howard, Scott C.

    2017-01-01

    Background Inadequate nursing care is a major impediment to development of effective programs for treatment of childhood cancer in low-income countries. When the International Outreach Program at St. Jude Children’s Research Hospital established partner sites in low-income countries, few nurses had pediatric oncology skills or experience. A comprehensive nursing program was developed to promote the provision of quality nursing care, and in this manuscript we describe the program’s impact on 20 selected Joint Commission International (JCI) quality standards at the National Pediatric Oncology Unit in Guatemala. We utilized JCI standards to focus the nursing evaluation and implementation of improvements. These standards were developed to assess public hospitals in low-income countries and are recognized as the gold standard of international quality evaluation. Methods We compared the number of JCI standards met before and after the nursing program was implemented using direct observation of nursing care; review of medical records, policies, procedures, and job descriptions; and interviews with staff. Results In 2006, only 1 of the 20 standards was met fully, 2 partially, and 17 not met. In 2009, 16 were met fully, 1 partially, and 3 not met. Several factors contributed to the improvement. The pre-program quality evaluation provided objective and credible findings and an organizational framework for implementing change. The medical, administrative, and nursing staff worked together to improve nursing standards. Conclusion A systematic approach and involvement of all hospital disciplines led to significant improvement in nursing care that was reflected by fully meeting 16 of 20 standards. PMID:23015363

  17. International Standards for Neurological Classification of Spinal Cord Injury: cases with classification challenges.

    PubMed

    Kirshblum, S C; Biering-Sorensen, F; Betz, R; Burns, S; Donovan, W; Graves, D E; Johansen, M; Jones, L; Mulcahey, M J; Rodriguez, G M; Schmidt-Read, M; Steeves, J D; Tansey, K; Waring, W

    2014-03-01

    The International Standards for the Neurological Classification of Spinal Cord Injury (ISNCSCI) is routinely used to determine the levels of injury and to classify the severity of the injury. Questions are often posed to the International Standards Committee of the American Spinal Injury Association regarding the classification. The committee felt that disseminating some of the challenging questions posed, as well as the responses, would be of benefit for professionals utilizing the ISNCSCI. Case scenarios that were submitted to the committee are presented with the responses as well as the thought processes considered by the committee members. The importance of this documentation is to clarify some points as well as update the SCI community regarding possible revisions that will be needed in the future based upon some rules that require clarification.

  18. Applications of a new wall function to turbulent flow computations

    NASA Astrophysics Data System (ADS)

    Chen, Y. S.

    1986-01-01

    A new wall function approach is developed based on a wall law suitable for incompressible turbulent boundary layers under strong adverse pressure gradients. This wall law was derived from a one-dimensional analysis of the turbulent kinetic energy equation with gradient diffusion concept employed in modeling the near-wall shear stress gradient. Numerical testing cases for the present wall functions include turbulent separating flows around an airfoil and turbulent recirculating flows in several confined regions. Improvements on the predictions using the present wall functions are illustrated. For cases of internal recirculating flows, one modification factor for improving the performance of the k-epsilon turbulence model in the flow recirculation regions is also included.

  19. Evaluation of medical record quality and communication skills among pediatric interns after standardized parent training history-taking in China.

    PubMed

    Yu, Mu Xue; Jiang, Xiao Yun; Li, Yi Juan; Shen, Zhen Yu; Zhuang, Si Qi; Gu, Yu Fen

    2018-02-01

    The effect of using standardized parent training history-taking on the quality of medical records and communication skills among pediatric interns was determined. Fifth-year interns who were undertaking a pediatric clinical practice rotation were randomized to intervention and control groups. All of the pediatric interns received history-taking training by lecture and bedside teaching. The pediatric interns in the intervention group also received standardized parent history-taking training. The following two outcome measures were used: the scores of medical records, which were written by the pediatric interns after history-taking from real parents of pediatric patients; and the communication assessment tool (CAT) assessed by real parents. The general information, history of present illness (HPI), past medical history, personal history, family history, diagnosis, diagnostic analysis, and differential diagnosis scores in the intervention group were significantly higher than the control group (p < 0.05). Assessment of the CAT indicated that the real parents were more satisfied with the pediatric interns in the intervention group. Standardized parent training history-taking is effective in improving the quality of medical records by pediatric interns. Standardized parent training history-taking is a superior teaching tool for clinical reasoning ability, as well as communication skills in clinical pediatric practice.

  20. 76 FR 70062 - Lifesaving Equipment: Production Testing and Harmonization With International Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-10

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 46 CFR Parts 160, 180, and 199 [Docket No. USCG-2010-0048] RIN 1625-AB46 Lifesaving Equipment: Production Testing and Harmonization With International Standards Correction In rule document 2011-25035, appearing on pages 62962-63015 in the issue of Monday...

  1. Rotational stabilization of the resistive wall modes in tokamaks with a ferritic wall

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pustovitov, V. D.; National Research Nuclear University “MEPhI,” Kashirskoe sh. 31, Moscow 115409; Yanovskiy, V. V.

    The dynamics of the rotating resistive wall modes (RWMs) is analyzed in the presence of a uniform ferromagnetic resistive wall with μ{sup ^}≡μ/μ{sub 0}≤4 (μ is the wall magnetic permeability, and μ{sub 0} is the vacuum one). This mimics a possible arrangement in ITER with ferromagnetic steel in test blanket modules or in future experiments in JT-60SA tokamak [Y. Kamada, P. Barabaschi, S. Ishida, the JT-60SA Team, and JT-60SA Research Plan Contributors, Nucl. Fusion 53, 104010 (2013)]. The earlier studies predict that such a wall must provide a destabilizing influence on the plasma by reducing the beta limit and increasingmore » the growth rates, compared to the reference case with μ{sup ^}=1. This is true for the locked modes, but the presented results show that the mode rotation changes the tendency to the opposite. At μ{sup ^}>1, the rotational stabilization related to the energy sink in the wall becomes even stronger than at μ{sup ^}=1, and this “external” effect develops at lower rotation frequency, estimated as several kHz at realistic conditions. The study is based on the cylindrical dispersion relation valid for arbitrary growth rates and frequencies. This relation is solved numerically, and the solutions are compared with analytical dependences obtained for slow (s/d{sub w}≫1) and fast (s/d{sub w}≪1) “ferromagnetic” rotating RWMs, where s is the skin depth and d{sub w} is the wall thickness. It is found that the standard thin-wall modeling becomes progressively less reliable at larger μ{sup ^}, and the wall should be treated as magnetically thick. The analysis is performed assuming only a linear plasma response to external perturbations without constraints on the plasma current and pressure profiles.« less

  2. Polymerization Kinetics: Monitoring Monomer Conversion Using an Internal Standard and the Key Role of Sample "t[subscript 0]"

    ERIC Educational Resources Information Center

    Colombani, Olivier; Langelier, Ophelie; Martwong, Ekkachai; Castignolles, Patrice

    2011-01-01

    The use of an internal standard is a conventional and convenient way to monitor the conversion of one or several monomers during a controlled radical polymerization. However, the validity of this technique relies on an accurate determination of the initial monomer-to-internal standard ratio, A[subscript 0], because all subsequent calculations of…

  3. International Standards and Reference Materials for Quantitative Molecular Infectious Disease Testing

    PubMed Central

    Madej, Roberta M.; Davis, Jack; Holden, Marcia J.; Kwang, Stan; Labourier, Emmanuel; Schneider, George J.

    2010-01-01

    The utility of quantitative molecular diagnostics for patient management depends on the ability to relate patient results to prior results or to absolute values in clinical practice guidelines. To do this, those results need to be comparable across time and methods, either by producing the same value across methods and test versions or by using reliable and stable conversions. Universally available standards and reference materials specific to quantitative molecular technologies are critical to this process but are few in number. This review describes recent history in the establishment of international standards for nucleic acid test development, organizations involved in current efforts, and future issues and initiatives. PMID:20075208

  4. International Consensus on Allergen Immunotherapy II: Mechanisms, standardization, and pharmacoeconomics.

    PubMed

    Jutel, Marek; Agache, Ioana; Bonini, Sergio; Burks, A Wesley; Calderon, Moises; Canonica, Walter; Cox, Linda; Demoly, Pascal; Frew, Antony J; O'Hehir, Robyn; Kleine-Tebbe, Jörg; Muraro, Antonella; Lack, Gideon; Larenas, Désirée; Levin, Michael; Martin, Bryan L; Nelson, Harald; Pawankar, Ruby; Pfaar, Oliver; van Ree, Ronald; Sampson, Hugh; Sublett, James L; Sugita, Kazunari; Du Toit, George; Werfel, Thomas; Gerth van Wijk, Roy; Zhang, Luo; Akdis, Mübeccel; Akdis, Cezmi A

    2016-02-01

    This article continues the comprehensive international consensus (ICON) statement on allergen immunotherapy (AIT). The initial article also recently appeared in the Journal. The conclusions below focus on key mechanisms of AIT-triggered tolerance, requirements in allergen standardization, AIT cost-effectiveness, and regulatory guidance. Potential barriers to and facilitators of the use of AIT are described in addition to future directions. International allergy specialists representing the European Academy of Allergy and Clinical Immunology; the American Academy of Allergy, Asthma & Immunology; the American College of Allergy, Asthma and Immunology; and the World Allergy Organization critically reviewed the existing literature and prepared this summary of recommendations for best AIT practice. The authors contributed equally and reached consensus on the statements presented herein. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  5. 30 years of battling the cell wall.

    PubMed

    Latgé, J P

    2017-01-01

    In Aspergillus fumigatus, like in other pathogenic fungi, the cell wall is essential for fungal growth as well as for resisting environmental stresses such as phagocytic killing. Most of the chemical analyses undertaken on the cell wall of A. fumigatus are focused on the mycelial cell wall because it is the vegetative stage of the fungus. However, the cell walls of the mycelium and conidium (which is the infective propagule) are different especially at the level of the surface layer, which plays a significant role in the interaction between A. fumigatus conidia and phagocytic cells of the immune system. In spite of the essential function of the cell wall in fungal life, progresses have been extremely slow in the understanding of biosynthesis as well in the identification of the key host responses against the cell wall components. A major difficulty is the fact that the composition and structural organization of the cell wall is not immutably set and is constantly reshuffled depending on the environmental conditions. © The Author 2016. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Collaborative study for the calibration of a replacement International Standard for Tetanus Toxoid Adsorbed.

    PubMed

    Tierney, Rob; Stickings, Paul; Hockley, Jason; Rigsby, Peter; Iwaki, Masaaki; Sesardic, Dorothea

    2011-11-01

    We present the results of a collaborative study for the establishment of a replacement International Standard (IS) for Tetanus Toxoid Adsorbed. Two candidate preparations were included in the study, one of which was established as the 4th IS for Tetanus Toxoid Adsorbed at the WHO Expert Committee on Biological Standardization meeting in October 2010. This preparation was found to have a unitage of 490 IU/ampoule, based on calibration in guinea pig challenge assays. Results from mouse challenge assays suggest that the relative performance of two candidate preparations may differ significantly between guinea pigs and mice. The authors note that the number of laboratories that performed guinea pig challenge assays, which are used to calibrate and assign IU, is much lower than in previous collaborative studies and this may have implications for calibration of replacement standards in the future. The issue of assigning separate units to the IS for guinea pig and mouse assays is discussed. The study also assessed performance of the replacement standard in serological assays which are used as alternative procedures to challenge assays for tetanus potency testing. Results suggest that the replacement standard is suitable for use as the reference vaccine in serological assays. Copyright © 2011 The International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.

  7. Large-eddy simulations with wall models

    NASA Technical Reports Server (NTRS)

    Cabot, W.

    1995-01-01

    The near-wall viscous and buffer regions of wall-bounded flows generally require a large expenditure of computational resources to be resolved adequately, even in large-eddy simulation (LES). Often as much as 50% of the grid points in a computational domain are devoted to these regions. The dense grids that this implies also generally require small time steps for numerical stability and/or accuracy. It is commonly assumed that the inner wall layers are near equilibrium, so that the standard logarithmic law can be applied as the boundary condition for the wall stress well away from the wall, for example, in the logarithmic region, obviating the need to expend large amounts of grid points and computational time in this region. This approach is commonly employed in LES of planetary boundary layers, and it has also been used for some simple engineering flows. In order to calculate accurately a wall-bounded flow with coarse wall resolution, one requires the wall stress as a boundary condition. The goal of this work is to determine the extent to which equilibrium and boundary layer assumptions are valid in the near-wall regions, to develop models for the inner layer based on such assumptions, and to test these modeling ideas in some relatively simple flows with different pressure gradients, such as channel flow and flow over a backward-facing step. Ultimately, models that perform adequately in these situations will be applied to more complex flow configurations, such as an airfoil.

  8. International standards on working postures and movements ISO 11226 and EN 1005-4.

    PubMed

    Delleman, N J; Dul, J

    2007-11-01

    Standards organizations have given considerable attention to the problem of work-related musculoskeletal disorders. The publication of international standards for evaluating working postures and movements, ISO 11,226 in 2000 and EN 1,005-4 in 2005, may be considered as a support for those involved in preventing and controlling these disorders. The first one is a tool for evaluation of existing work situations, whereas the latter one is a tool for evaluation during a design/engineering process. Key publications and considerations that led to the content of the standards are presented, followed by examples of application.

  9. A decade of international cooperation brings a standard seismic point of view

    USGS Publications Warehouse

    Whitcomb, H. S

    1971-01-01

    Whether in a castle in Italy, a police station in Iceland, o an abandoned gold mine in Australia, the sensitive instruments in the Worldwide Seismograph Network send a steady flow of standard earthquake records to the geophysical scientific community. They provide the raw data that make possible very precise earthquake studies, precise because the instruments are identical and their product standard. A truly international program, this network of 115 stations in 61 countires and territories has laid the foundation for reserach in seismology for many years to come. 

  10. 49 CFR 178.521 - Standards for paper bags.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Standards for paper bags. 178.521 Section 178.521...-Oriented Packaging Standards § 178.521 Standards for paper bags. (a) The following are identification codes for paper bags: (1) 5M1 for a multi-wall paper bag; and (2) 5M2 for a multi-wall water-resistant paper...

  11. 49 CFR 178.521 - Standards for paper bags.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Standards for paper bags. 178.521 Section 178.521...-bulk Performance-Oriented Packaging Standards § 178.521 Standards for paper bags. (a) The following are identification codes for paper bags: (1) 5M1 for a multi-wall paper bag; and (2) 5M2 for a multi-wall water...

  12. Standard payload computer for the international space station

    NASA Astrophysics Data System (ADS)

    Knott, Karl; Taylor, Chris; Koenig, Horst; Schlosstein, Uwe

    1999-01-01

    This paper describes the development and application of a Standard PayLoad Computer (SPLC) which is being applied by the majority of ESA payloads accommodated on the International Space Station (ISS). The strategy of adopting of a standard computer leads to a radical rethink in the payload data handling procurement process. Traditionally, this has been based on a proprietary development with repeating costs for qualification, spares, expertise and maintenance for each new payload. Implementations have also tended to be unique with very little opportunity for reuse or utilisation of previous developments. While this may to some extent have been justified for short duration one-off missions, the availability of a standard, long term space infrastructure calls for a quite different approach. To support a large number of concurrent payloads, the ISS implementation relies heavily on standardisation, and this is particularly true in the area of payloads. Physical accommodation, data interfaces, protocols, component quality, operational requirements and maintenance including spares provisioning must all conform to a common set of standards. The data handling system and associated computer used by each payload must also comply with these common requirements, and thus it makes little sense to instigate multiple developments for the same task. The opportunity exists to provide a single computer suitable for all payloads, but with only a one-off development and qualification cost. If this is combined with the benefits of multiple procurement, centralised spares and maintenance, there is potential for great savings to be made by all those concerned in the payload development process. In response to the above drivers, the SPLC is based on the following concepts: • A one-off development and qualification process • A modular computer, configurable according to the payload developer's needs from a list of space-qualified items • An `open system' which may be added to by

  13. Determination of low intrinsic clearance in vitro: the benefit of a novel internal standard in human hepatocyte incubations.

    PubMed

    Zanelli, Ugo; Michna, Thomas; Petersson, Carl

    2018-03-26

    1. A novel method utilizing an internal standard in hepatocytes incubations has been developed and demonstrated to decrease the variability in the determination of intrinsic clearance (CL int ) in this system. The reduced variability was shown to allow differentiation of lower elimination rate constants from noise. 2. The suggested method was able to compensate for a small but systematic error (0.5 µL/min/10 6 cells) caused by an evaporation of approximately 15% of the volume during the incubation time. 3. The approach was validated using six commercial drugs (ketoprofen, tolbutamide, phenacetin, etodolac and quinidine) which were metabolized by different pathways. 4. The suggested internal standard, MSC1815677, was extensively characterized and the acquired data suggest that it fulfills the requirements of an internal standard present during the incubation. The proposed internal standard was stable during the incubation and showed a low potential to inhibit drug metabolizing enzymes and transporters. With MSC1815677 we propose a novel simple, robust and cost-effective method to address the challenges in the estimation of low clearance in hepatocyte incubations.

  14. Extended Plate and Beam Wall System: Concept Investigation and Initial Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiehagen, J.; Kochkin, V.

    A new and innovative High-R wall design, referred to as the Extended Plate & Beam (EP&B), is under development. The EP&B system uniquely integrates foam sheathing insulation with wall framing such that wood structural panels are installed exterior of the foam sheathing, enabling the use of standard practices for installation of drainage plane, windows and doors, claddings, cavity insulation, and the standard exterior foam sheathing installation approach prone to damage of the foam during transportation of prefabricated wall panels. As part of the ongoing work, the EP&B wall system concept has undergone structural verification testing and has been positively vettedmore » by a group of industry stakeholders. Having passed these initial milestone markers, the advanced wall system design has been analyzed to assess cost implications relative to other advanced wall systems, undergone design assessment to develop construction details, and has been evaluated to develop representative prescriptive requirements for the building code. This report summarizes the assessment steps conducted to-date and provides details of the concept development.« less

  15. Extended Plate and Beam Wall System: Concept Investigation and Initial Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiehagen, J.; Kochkin, V.

    2015-08-01

    A new and innovative High-R wall design, referred to as the Extended Plate & Beam (EP&B), is under development. The EP&B system uniquely integrates foam sheathing insulation with wall framing such that wood structural panels are installed exterior of the foam sheathing, enabling the use of standard practices for installation of drainage plane, windows and doors, claddings, cavity insulation, and the standard exterior foam sheathing installation approach prone to damage of the foam during transportation of prefabricated wall panels. As part of the ongoing work, the EP&B wall system concept has undergone structural verification testing and has been positively vettedmore » by a group of industry stakeholders. Having passed these initial milestone markers, the advanced wall system design has been analyzed to assess cost implications relative to other advanced wall systems, undergone design assessment to develop construction details, and has been evaluated to develop representative prescriptive requirements for the building code. This report summarizes the assessment steps conducted to-date and provides details of the concept development.« less

  16. Measurement of Henry's Law Constants Using Internal Standards: A Quantitative GC Experiment for the Instrumental Analysis or Environmental Chemistry Laboratory

    ERIC Educational Resources Information Center

    Ji, Chang; Boisvert, Susanne M.; Arida, Ann-Marie C.; Day, Shannon E.

    2008-01-01

    An internal standard method applicable to undergraduate instrumental analysis or environmental chemistry laboratory has been designed and tested to determine the Henry's law constants for a series of alkyl nitriles. In this method, a mixture of the analytes and an internal standard is prepared and used to make a standard solution (organic solvent)…

  17. High-resolution 3D coronary vessel wall imaging with near 100% respiratory efficiency using epicardial fat tracking: reproducibility and comparison with standard methods.

    PubMed

    Scott, Andrew D; Keegan, Jennifer; Firmin, David N

    2011-01-01

    To quantitatively assess the performance and reproducibility of 3D spiral coronary artery wall imaging with beat-to-beat respiratory-motion-correction (B2B-RMC) compared to navigator gated 2D spiral and turbo-spin-echo (TSE) acquisitions. High-resolution (0.7 × 0.7 mm) cross-sectional right coronary wall acquisitions were performed in 10 subjects using four techniques (B2B-RMC 3D spiral with alternate (2RR) and single (1RR) R-wave gating, navigator-gated 2D spiral (2RR) and navigator-gated 2D TSE (2RR)) on two occasions. Wall thickness measurements were compared with repeated measures analysis of variance (ANOVA). Reproducibility was assessed with the intraclass correlation coefficient (ICC). In all, 91% (73/80) of acquisitions were successful (failures: four TSE, two 3D spiral (1RR) and one 3D spiral (2RR)). Respiratory efficiency of the B2B-RMC was less variable and substantially higher than for navigator gating (99.6 ± 1.2% vs. 39.0 ± 7.5%, P < 0.0001). Coronary wall thicknesses (± standard deviation [SD]) were not significantly different: 1.10 ± 0.14 mm (3D spiral (2RR)), 1.20 ± 0.16 mm (3D spiral (1RR)), 1.14 ± 0.15 mm (2D spiral), and 1.21 ± 0.17 mm (TSE). Wall thickness reproducibility ranged from good (ICC = 0.65, 3D spiral (1RR)) to excellent (ICC = 0.87, 3D spiral (2RR)). High-resolution 3D spiral imaging with B2B-RMC permits coronary vessel wall assessment over multiple thin contiguous slices in a clinically feasible duration. Excellent reproducibility of the technique potentially enables studies of disease progression/regression. Copyright © 2010 Wiley-Liss, Inc.

  18. An Exploratory Study of the Perceptions of AACSB International's 2013 Accreditation Standards

    ERIC Educational Resources Information Center

    Miles, Morgan P.; Franklin, Geralyn McClure; Grimmer, Martin; Heriot, Kirl C.

    2015-01-01

    Purpose: The purpose of this paper is to report on the findings of an exploratory survey designed to measure AACSB member deans' perceptions about the recently revised 2013 Association to Advance Collegiate Schools of Business (AACSB) Accreditation Standards. In April of 2013, AACSB International released a major revision of its accreditation…

  19. International migration: security concerns and human rights standards.

    PubMed

    Crépeau, François; Nakache, Delphine; Atak, Idil

    2007-09-01

    Over the last two decades, the reinforcement of security-related migration policies has resulted in the perception of the foreigner, and especially the irregular migrant, as a category outside the circle of legality. The rights of foreigners in host countries have deteriorated due to the connection made between immigration and criminality. Restrictions imposed upon irregular migrants' basic political and civil rights have been accompanied by major obstacles to their access to economic and social rights, including the right to health. The events of 9/11 further contributed to this trend, which contradicts the basic premises of the human rights paradigm. Recent policy developments and ongoing international cooperation implementing systematic interception and interdiction mechanisms have led to the securitization of migration. The preventive and deterrent measures reinforce the security paradigm. By contrast, various national and international actors have been successful in defending irregular migrants' rights. At the domestic level, the involvement of the judiciary and civil society enhances the rights-based approach to foreigners. The role of judges is vital in holding policy-makers accountable for respecting the high national standards of human rights protection. This article elaborates on the dichotomy between the state's legitimate interest to ensure national security, and its domestic and international obligations to protect human rights for all, including irregular migrants. It focuses on the changing relationship between migration and security, on the one hand, and between state and individual, on the other hand. It affirms the necessity to recognize the pre-eminence of fundamental rights upon security concerns.

  20. The Determination of Sugars in Dairy Products: Development of a New Standard Method for the International Dairy Federation and the Internal Organization for Standardization.

    PubMed

    Sanders, Peter; Ernste-Nota, Veronica; Visser, Klaas; van Soest, Jeroen; Brunt, Kommer

    2017-09-01

    A method using high-performance anion-exchange chromatography (HPAEC) with a pulsed amperometric detector (PAD) for the determination of mono- and disaccharides is described. The method was accepted by the International Dairy Federation and the Internal Organization for Standardization as a new work item for the determination of sugars in dairy matrixes, and the Milk and Milk Products technical committee of ISO/TC 34/SC 5 accepted the topic "Milk and milk products - Determination of the sugar contents - High-performance anion-exchange chromatographic method (HPAEC-PAD)" as a new work item. The proposed method consists of an aqueous ethanol extraction of the sugars in the dairy sample, followed by clarification with Carrez I and II reagents. The clarified filtrate is diluted and then directly introduced in the HPAEC-PAD system for quantification of the sugars. A single-laboratory validation of the proposed method has been scheduled for spring 2017.

  1. International estimated fetal weight standards of the INTERGROWTH-21st Project.

    PubMed

    Stirnemann, J; Villar, J; Salomon, L J; Ohuma, E; Ruyan, P; Altman, D G; Nosten, F; Craik, R; Munim, S; Cheikh Ismail, L; Barros, F C; Lambert, A; Norris, S; Carvalho, M; Jaffer, Y A; Noble, J A; Bertino, E; Gravett, M G; Purwar, M; Victora, C G; Uauy, R; Bhutta, Z; Kennedy, S; Papageorghiou, A T

    2017-04-01

    Estimated fetal weight (EFW) and fetal biometry are complementary measures used to screen for fetal growth disturbances. Our aim was to provide international EFW standards to complement the INTERGROWTH-21 st Fetal Growth Standards that are available for use worldwide. Women with an accurate gestational-age assessment, who were enrolled in the prospective, international, multicenter, population-based Fetal Growth Longitudinal Study (FGLS) and INTERBIO-21 st Fetal Study (FS), two components of the INTERGROWTH-21 st Project, had ultrasound scans every 5 weeks from 9-14 weeks' until 40 weeks' gestation. At each visit, measurements of fetal head circumference (HC), biparietal diameter, occipitofrontal diameter, abdominal circumference (AC) and femur length (FL) were obtained blindly by dedicated research sonographers using standardized methods and identical ultrasound machines. Birth weight was measured within 12 h of delivery by dedicated research anthropometrists using standardized methods and identical electronic scales. Live babies without any congenital abnormality, who were born within 14 days of the last ultrasound scan, were selected for inclusion. As most births occurred at around 40 weeks' gestation, we constructed a bootstrap model selection and estimation procedure based on resampling of the complete dataset under an approximately uniform distribution of birth weight, thus enriching the sample size at extremes of fetal sizes, to achieve consistent estimates across the full range of fetal weight. We constructed reference centiles using second-degree fractional polynomial models. Of the overall population, 2404 babies were born within 14 days of the last ultrasound scan. Mean time between the last scan and birth was 7.7 (range, 0-14) days and was uniformly distributed. Birth weight was best estimated as a function of AC and HC (without FL) as log(EFW) = 5.084820 - 54.06633 × (AC/100) 3  - 95.80076 × (AC/100) 3  × log(AC/100)

  2. Proposed Standards for Medical Education Submissions to the Journal of General Internal Medicine

    PubMed Central

    Bowen, Judith L.; Gerrity, Martha S.; Kalet, Adina L.; Kogan, Jennifer R.; Spickard, Anderson; Wayne, Diane B.

    2008-01-01

    To help authors design rigorous studies and prepare clear and informative manuscripts, improve the transparency of editorial decisions, and raise the bar on educational scholarship, the Deputy Editors of the Journal of General Internal Medicine articulate standards for medical education submissions to the Journal. General standards include: (1) quality questions, (2) quality methods to match the questions, (3) insightful interpretation of findings, (4) transparent, unbiased reporting, and (5) attention to human subjects’ protection and ethical research conduct. Additional standards for specific study types are described. We hope these proposed standards will generate discussion that will foster their continued evolution. Electronic supplementary material The online version of this article (doi:10.1007/s11606-008-0676-z) contains supplementary material, which is available to authorized users. PMID:18612716

  3. Starworld: Preparing Accountants for the Future: A Case-Based Approach to Teach International Financial Reporting Standards Using ERP Software

    ERIC Educational Resources Information Center

    Ragan, Joseph M.; Savino, Christopher J.; Parashac, Paul; Hosler, Jonathan C.

    2010-01-01

    International Financial Reporting Standards now constitute an important part of educating young professional accountants. This paper looks at a case based process to teach International Financial Reporting Standards using integrated Enterprise Resource Planning software. The case contained within the paper can be used within a variety of courses…

  4. Standardization of haematology critical results management in adults: an International Council for Standardization in Haematology, ICSH, survey and recommendations.

    PubMed

    Keng, T B; De La Salle, B; Bourner, G; Merino, A; Han, J-Y; Kawai, Y; Peng, M T; McCafferty, R

    2016-10-01

    These recommendations are intended to develop a consensus in the previously published papers as to which parameters and what values should be considered critical. A practical guide on the standardization of critical results management in haematology laboratories would be beneficial as part of good laboratory and clinical practice and for use by laboratory-accrediting agencies. A working group with members from Europe, America, Australasia and Asia was formed by International Council for Standardization in Haematology. A pattern of practice survey of 21 questions was distributed in 2014, and the data were collected electronically by Survey Monkey. The mode, or most commonly occurring value, was selected as the threshold for the upper and lower alert limits for critical results reporting. A total of 666 laboratories submitted data to this study and, of these, 499 submitted complete responses. Full blood count critical results alert thresholds, morphology findings that trigger critical result notification, critical results alert list, notification process and maintenance of critical results management protocol are described. This international survey provided a snapshot of the current practice worldwide and has identified the existence of considerable heterogeneity of critical results management. The recommendations in this study represent a consensus of good laboratory practice. They are intended to encourage the implementation of a standardized critical results management protocol in the laboratory. © 2016 John Wiley & Sons Ltd.

  5. International Comparisons of Foundation Phase Number Domain Mathematics Knowledge and Practice Standards

    ERIC Educational Resources Information Center

    Human, Anja; van der Walt, Marthie; Posthuma, Barbara

    2015-01-01

    Poor mathematics performance in schools is both a national and an international concern. Teachers ought to be equipped with relevant subject matter knowledge and pedagogical content knowledge as one way to address this problem. However, no mathematics knowledge and practice standards have as yet been defined for the preparation of Foundation Phase…

  6. Comparison of 4-chloro-2-nitrophenol adsorption on single-walled and multi-walled carbon nanotubes

    PubMed Central

    2012-01-01

    The adsorption characteristics of 4-chloro-2-nitrophenol (4C2NP) onto single-walled and multi-walled carbon nanotubes (SWCNTs and MWCNTs) from aqueous solution were investigated with respect to the changes in the contact time, pH of solution, carbon nanotubes dosage and initial 4C2NP concentration. Experimental results showed that the adsorption efficiency of 4C2NP by carbon nanotubes (both of SWCNTs and MWCNTs) increased with increasing the initial 4C2NP concentration. The maximum adsorption took place in the pH range of 2–6. The linear correlation coefficients of different isotherm models were obtained. Results revealed that the Langmuir isotherm fitted the experimental data better than the others and based on the Langmuir model equation, maximum adsorption capacity of 4C2NP onto SWCNTs and MWCNTs were 1.44 and 4.42 mg/g, respectively. The observed changes in the standard Gibbs free energy, standard enthalpy and standard entropy showed that the adsorption of 4C2NP onto SWCNTs and MWCNTs is spontaneous and exothermic in the temperature range of 298–328 K. PMID:23369489

  7. Partial synthesis of ganglioside and lysoganglioside lipoforms as internal standards for MS quantification.

    PubMed

    Gantner, Martin; Schwarzmann, Günter; Sandhoff, Konrad; Kolter, Thomas

    2014-12-01

    Within recent years, ganglioside patterns have been increasingly analyzed by MS. However, internal standards for calibration are only available for gangliosides GM1, GM2, and GM3. For this reason, we prepared homologous internal standards bearing nonnatural fatty acids of the major mammalian brain gangliosides GM1, GD1a, GD1b, GT1b, and GQ1b, and of the tumor-associated gangliosides GM2 and GD2. The fatty acid moieties were incorporated after selective chemical or enzymatic deacylation of bovine brain gangliosides. For modification of the sphingoid bases, we developed a new synthetic method based on olefin cross metathesis. This method was used for the preparation of a lyso-GM1 and a lyso-GM2 standard. The total yield of this method was 8.7% for the synthesis of d17:1-lyso-GM1 from d20:1/18:0-GM1 in four steps. The title compounds are currently used as calibration substances for MS quantification and are also suitable for functional studies. Copyright © 2014 by the American Society for Biochemistry and Molecular Biology, Inc.

  8. Technique for repair of fractures and separations involving the cartilaginous portions of the anterior chest wall.

    PubMed

    Bonne, Stephanie L; Turnbull, Isaiah R; Southard, Robert E

    2015-06-01

    Internal fixation of the ribs has been shown in numerous studies to decrease complications following traumatic rib fractures. Anterior injuries to the chest wall causing cartilaginous fractures, although rare, can cause significant disability and can lead to a variety of complications and, therefore, pose a unique clinical problem. Here, we report the surgical technique used for four patients with internal fixation of injuries to the cartilaginous portions of the chest wall treated at our center. All patients had excellent clinical outcomes and reported improvement in symptoms, with no associated complications. Patients who have injuries to the anterior portions of the chest wall should be considered for internal fixation of the chest wall when the injuries are severe and can lead to clinical disability.

  9. 76 FR 9547 - Light-Walled Rectangular Pipe and Tube From Mexico; Final Results of Antidumping Duty...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-18

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-201-836] Light-Walled Rectangular... preliminary results of the administrative review of the antidumping duty order on light-walled rectangular... light-walled rectangular pipe and tube from Mexico. See Light-Walled Rectangular Pipe and Tube From...

  10. 40 CFR 60.4203 - How long must my engines meet the emission standards if I am a stationary CI internal combustion...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emission standards if I am a stationary CI internal combustion engine manufacturer? 60.4203 Section 60.4203... Combustion Engines Emission Standards for Manufacturers § 60.4203 How long must my engines meet the emission standards if I am a stationary CI internal combustion engine manufacturer? Engines manufactured by...

  11. 40 CFR 60.4203 - How long must my engines meet the emission standards if I am a stationary CI internal combustion...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... emission standards if I am a stationary CI internal combustion engine manufacturer? 60.4203 Section 60.4203... Combustion Engines Emission Standards for Manufacturers § 60.4203 How long must my engines meet the emission standards if I am a stationary CI internal combustion engine manufacturer? Engines manufactured by...

  12. Asbestos in Plaster and Wall Systems

    EPA Pesticide Factsheets

    This collection of letters and clarification on final rules provides guidance on Asbestos National Emissions Standard for Hazardous Air Pollutants for asbestos-containing join compounds, and asbestos-containing materials found in plaster and wall systems.

  13. Fracture resistance of welded thick-walled high-pressure vessels in power plants. Report No. 2. Approach to evaluating static strength

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gorynin, I.V.; Filatov, V.M.; Ignatov, V.A.

    1986-07-01

    The authors examine data on the effect of defects on the fracture resistance of high-pressure vessels and their models obtained within the framework of the HSST program. Results of internal-pressure tests of two types of vessels with a wall thickness of 152 mm made from forgings of steels SA508 and SA533, as well as small vessels with a wall thickness of 11.5 and 23mm made of steel SA533 are shown. The authors state that testing thick-walled welded high-pressure vessels and thin-walled vessels with surface defects of different sizes has demonstrated that there are substantial static-strength reserves in structures designed bymore » existing domestic and foreign standards on the strength of power-plant equipment. A correction was proposed for the presently used method of calculating the resistance of highpressure vessels to brittle fracture that allows for the dimensions of the defects in relation to the type of vessel, the manufacturing technology, and the method of inspection.« less

  14. Reflections on International Bibliographic Standards.

    ERIC Educational Resources Information Center

    Roberts, W.

    This paper raises questions about many bibliographic standards developed over the past 20 years, and challenges librarians to consider how standards might evolve. A brief overview is given of the aims of Universal Bibliographic Control (UBC) and to some assumptions common to much standardization work in recent years inspired by the concept of UBC.…

  15. Genomic Sequence of the WHO International Standard for Hepatitis A Virus RNA.

    PubMed

    Jenkins, Adrian; Minhas, Rehan; Morris, Clare; Berry, Neil

    2018-05-10

    The World Health Organization (WHO) international standard for hepatitis A virus (HAV) RNA nucleic acid assays was characterized by complete genome sequencing. The entire coding sequence and noncoding regions were assigned HAV genotype IB. This information will aid the design, development, and evaluation of HAV RNA amplification assays. Copyright © 2018 Jenkins et al.

  16. An evaluation of the relative safety of U.S. mining explosion-protected equipment approval requirements versus international standards

    PubMed Central

    Calder, W.; Snyder, D.; Burr, J.F.

    2018-01-01

    This paper provides a determination of the equivalent level of protection of the international standards relative to similar criteria used by the U.S. Mine Safety and Health Administration (MSHA) to approve two-fault intrinsically safe (IS) stand-alone equipment. U.S. mining law requires such a determination for MSHA to use alternatives to existing standards. The primary issue is to demonstrate that the international standards for equipment evaluation will provide at least the same level of protection for miners as the document currently used by MSHA. PMID:29780219

  17. Electrical resisitivity of mechancially stablized earth wall backfill

    NASA Astrophysics Data System (ADS)

    Snapp, Michael; Tucker-Kulesza, Stacey; Koehn, Weston

    2017-06-01

    Mechanically stabilized earth (MSE) retaining walls utilized in transportation projects are typically backfilled with coarse aggregate. One of the current testing procedures to select backfill material for construction of MSE walls is the American Association of State Highway and Transportation Officials standard T 288: ;Standard Method of Test for Determining Minimum Laboratory Soil Resistivity.; T 288 is designed to test a soil sample's electrical resistivity which correlates to its corrosive potential. The test is run on soil material passing the No. 10 sieve and believed to be inappropriate for coarse aggregate. Therefore, researchers have proposed new methods to measure the electrical resistivity of coarse aggregate samples in the laboratory. There is a need to verify that the proposed methods yield results representative of the in situ conditions; however, no in situ measurement of the electrical resistivity of MSE wall backfill is established. Electrical resistivity tomography (ERT) provides a two-dimensional (2D) profile of the bulk resistivity of backfill material in situ. The objective of this study was to characterize bulk resistivity of in-place MSE wall backfill aggregate using ERT. Five MSE walls were tested via ERT to determine the bulk resistivity of the backfill. Three of the walls were reinforced with polymeric geogrid, one wall was reinforced with metallic strips, and one wall was a gravity retaining wall with no reinforcement. Variability of the measured resistivity distribution within the backfill may be a result of non-uniform particle sizes, thoroughness of compaction, and the presence of water. A quantitative post processing algorithm was developed to calculate mean bulk resistivity of in-situ backfill. Recommendations of the study were that the ERT data be used to verify proposed testing methods for coarse aggregate that are designed to yield data representative of in situ conditions. A preliminary analysis suggests that ERT may be utilized

  18. International Space Station medical standards and certification for space flight participants.

    PubMed

    Bogomolov, Valery V; Castrucci, Filippo; Comtois, Jean-Marc; Damann, Volker; Davis, Jeffrey R; Duncan, J Michael; Johnston, Smith L; Gray, Gary W; Grigoriev, Anatoly I; Koike, Yu; Kuklinski, Paul; Matveyev, Vladimir P; Morgun, Valery V; Pochuev, Vladimir I; Sargsyan, Ashot E; Shimada, Kazuhito; Straube, Ulrich; Tachibana, Shoichi; Voronkov, Yuri V; Williams, Richard S

    2007-12-01

    The medical community of the International Space Station (ISS) has developed joint medical standards and evaluation requirements for Space Flight Participants ("space tourists") which are used by the ISS medical certification board to determine medical eligibility of individuals other than professional astronauts (cosmonauts) for short-duration space flight to the ISS. These individuals are generally fare-paying passengers without operational responsibilities. By means of this publication, the medical standards and evaluation requirements for the ISS Space Flight Participants are offered to the aerospace medicine and commercial spaceflight communities for reference purposes. It is emphasized that the criteria applied to the ISS spaceflight participant candidates are substantially less stringent than those for professional astronauts and/or crewmembers of visiting and long-duration missions to the ISS. These medical standards are released by the government space agencies to facilitate the development of robust medical screening and medical risk assessment approaches in the context of the evolving commercial human spaceflight industry.

  19. Recording Rapidly Changing Cylinder-wall Temperatures

    NASA Technical Reports Server (NTRS)

    Meier, Adolph

    1942-01-01

    The present report deals with the design and testing of a measuring plug suggested by H. Pfriem for recording quasi-stationary cylinder wall temperatures. The new device is a resistance thermometer, the temperature-susceptible part of which consists of a gold coating applied by evaporation under high vacuum and electrolytically strengthened. After overcoming initial difficulties, calibration of plugs up to and beyond 400 degrees C was possible. The measurements were made on high-speed internal combustion engines. The increasing effect of carbon deposit at the wall surface with increasing operating period is indicated by means of charts.

  20. Processes in the development of international specialist competencies and standards: the Sports Physiotherapy for All Project.

    PubMed

    Bulley, Catherine; Donaghy, Marie

    2008-01-01

    In a world of rapidly developing knowledge it is important that professions describe their roles and capabilities. The need for a thorough description of sports physiotherapy was addressed through collaboration between the International Federation of Sports Physiotherapy (IFSP) and five European higher education institutions. This resulted in the Sports Physiotherapy for All Project, which has been successful in developing internationally accepted competencies and standards for sports physiotherapists. This article describes and reflects on the process to communicate useful lessons. A competency model was chosen to facilitate differentiation and communication of aspects of sports physiotherapy practice. Documentation relating to sports physiotherapy practice was collected from 16 countries and analysed thematically. A cut and paste method was used by a panel of experts to allocate themes to areas of practice within the competency model. Theme groups were used to select areas of practice for description in competency form. Standards were derived from competencies following in depth discussion with the expert panel, and triangulation with themes derived from international documentation. A rigorous process of international review and revision led to the final list of 11 competencies and related standards, both accepted by the IFSP. This work provides a foundation for the development of an audit toolkit to guide demonstration and evaluation of competencies and standards. This provides a foundation for targeted career development activities, appropriate provision of training opportunities, and quality enhancement. The experiences gained during this project can inform other health professions and their specialisms when embarking on a similar journey.

  1. Taking the Lead in Science Education: Forging Next-Generation Science Standards. International Science Benchmarking Report. Appendix

    ERIC Educational Resources Information Center

    Achieve, Inc., 2010

    2010-01-01

    This appendix accompanies the report "Taking the Lead in Science Education: Forging Next-Generation Science Standards. International Science Benchmarking Report," a study conducted by Achieve to compare the science standards of 10 countries. This appendix includes the following: (1) PISA and TIMSS Assessment Rankings; (2) Courses and…

  2. International Society for the Advancement of Cytometry cell sorter biosafety standards.

    PubMed

    Holmes, Kevin L; Fontes, Benjamin; Hogarth, Philip; Konz, Richard; Monard, Simon; Pletcher, Charles H; Wadley, Robert B; Schmid, Ingrid; Perfetto, Stephen P

    2014-05-01

    Flow cytometric cell sorting of biological specimens has become prevalent in basic and clinical research laboratories. These specimens may contain known or unknown infectious agents, necessitating precautions to protect instrument operators and the environment from biohazards arising from the use of sorters. To this end the International Society of Analytical Cytology (ISAC) was proactive in establishing biosafety guidelines in 1997 (Schmid et al., Cytometry 1997;28:99-117) and subsequently published revised biosafety standards for cell sorting of unfixed samples in 2007 (Schmid et al., Cytometry Part A J Int Soc Anal Cytol 2007;71A:414-437). Since their publication, these documents have become recognized worldwide as the standard of practice and safety precautions for laboratories performing cell sorting experiments. However, the field of cytometry has progressed since 2007, and the document requires an update. The new Standards provides guidance: (1) for laboratory design for cell sorter laboratories; (2) for the creation of laboratory or instrument specific Standard Operating Procedures (SOP); and (3) on procedures for the safe operation of cell sorters, including personal protective equipment (PPE) and validation of aerosol containment. Published © 2014 Wiley Periodicals Inc.

  3. International Society for the Advancement of Cytometry Cell Sorter Biosafety Standards

    PubMed Central

    Holmes, Kevin L.; Fontes, Benjamin; Hogarth, Philip; Konz, Richard; Monard, Simon; Pletcher, Charles H.; Wadley, Robert B.; Schmid, Ingrid; Perfetto, Stephen P.

    2014-01-01

    Flow cytometric cell sorting of biological specimens has become prevalent in basic and clinical research laboratories. These specimens may contain known or unknown infectious agents, necessitating precautions to protect instrument operators and the environment from biohazards arising from the use of sorters. To this end the International Society of Analytical Cytology (ISAC) was proactive in establishing biosafety guidelines in 1997 (Schmid et al., Cytometry 1997;28:99–117) and subsequently published revised biosafety standards for cell sorting of unfixed samples in 2007 (Schmid et al., Cytometry Part A J Int Soc Anal Cytol 2007;71A:414–437). Since their publication, these documents have become recognized worldwide as the standard of practice and safety precautions for laboratories performing cell sorting experiments. However, the field of cytometry has progressed since 2007, and the document requires an update. The new Standards provides guidance: (1) for laboratory design for cell sorter laboratories; (2) for the creation of laboratory or instrument specific Standard Operating Procedures (SOP); and (3) on procedures for the safe operation of cell sorters, including personal protective equipment (PPE) and validation of aerosol containment. PMID:24634405

  4. Selected Lessons Learned over the ISS Design, Development, Assembly, and Operations: Applicability to International Cooperation for Standardization

    NASA Technical Reports Server (NTRS)

    Hirsch, David B.

    2010-01-01

    This slide presentation reviews some of the lessons learned in the sphere of international cooperation during the development, assembly and operation of the International Space Station. From the begining all Partners shared a common objective to build, operate and utilize a crewed laboratory in low orbit as an international partnership. The importance of standards is emphasized.

  5. The roles of thermal insulation and heat storage in the energy performance of the wall materials: a simulation study.

    PubMed

    Long, Linshuang; Ye, Hong

    2016-04-07

    A high-performance envelope is the prerequisite and foundation to a zero energy building. The thermal conductivity and volumetric heat capacity of a wall are two thermophysical properties that strongly influence the energy performance. Although many case studies have been performed, the results failed to give a big picture of the roles of these properties in the energy performance of an active building. In this work, a traversal study on the energy performance of a standard room with all potential wall materials was performed for the first time. It was revealed that both heat storage materials and insulation materials are suitable for external walls. However, the importances of those materials are distinct in different situations: the heat storage plays a primary role when the thermal conductivity of the material is relatively high, but the effect of the thermal insulation is dominant when the conductivity is relatively low. Regarding internal walls, they are less significant to the energy performance than the external ones, and they need exclusively the heat storage materials with a high thermal conductivity. These requirements for materials are consistent under various climate conditions. This study may provide a roadmap for the material scientists interested in developing high-performance wall materials.

  6. The roles of thermal insulation and heat storage in the energy performance of the wall materials: a simulation study

    PubMed Central

    Long, Linshuang; Ye, Hong

    2016-01-01

    A high-performance envelope is the prerequisite and foundation to a zero energy building. The thermal conductivity and volumetric heat capacity of a wall are two thermophysical properties that strongly influence the energy performance. Although many case studies have been performed, the results failed to give a big picture of the roles of these properties in the energy performance of an active building. In this work, a traversal study on the energy performance of a standard room with all potential wall materials was performed for the first time. It was revealed that both heat storage materials and insulation materials are suitable for external walls. However, the importances of those materials are distinct in different situations: the heat storage plays a primary role when the thermal conductivity of the material is relatively high, but the effect of the thermal insulation is dominant when the conductivity is relatively low. Regarding internal walls, they are less significant to the energy performance than the external ones, and they need exclusively the heat storage materials with a high thermal conductivity. These requirements for materials are consistent under various climate conditions. This study may provide a roadmap for the material scientists interested in developing high-performance wall materials. PMID:27052186

  7. Evolution of activities in international biological standardization since the early days of the Health Organisation of the League of Nations.

    PubMed

    Sizaret, P

    1988-01-01

    The main activities in international biological standardization during the 18 years that followed the first international biological standardization meeting in London in 1921 were concerned with expressing the potencies of test preparations in comparison with reference materials. After the Second World War, however, it became clear that the testing of biological substances against international reference materials was only one among several measures for obtaining safe and potent products. The activities in international biological standardization were therefore widened so that, by the strict observance of specific manufacturing and control requirements, it was possible to gain further in safety and efficacy. At the end of 1987, 42 international requirements for biological substances were available and were being used as national requirements, sometimes after minor modification, by the majority of WHO's Member States. This is of utmost importance for the worldwide use of safe and potent biological products, including vaccines.

  8. Walls or Bridges: "No Gobbledygook": The International Psycho-Oncology Society 2017 Sutherland Award Lecture.

    PubMed

    Loscalzo, Matthew J

    2018-05-01

    Illness, health, and wellness happen in social contexts. The present political environment is highly divisive and plays to the most primitive fears of people. Never have the stakes been so high. History is replete with putative leaders who create walls that separate people in ways that inevitably leads to dehumanization, suffering, and eventually violence. Timely and openly shared psychosocial insights by experts in mental health into the evil consequences of "wall builders" are essential to the physical, mental, and spiritual health of individuals and nations. For health care professionals (in particular) to ignore the dangers posed by the ill equipped self-serving leaders who now dominate the news and exploit the dark psyche of the world stage would be at the very least unethical and at worst collusion in repeating the sins of the past. This article first recognizes the impact of leaders who, at great personal costs, have built bridges (with relentless compassion and courage) where only chasms existed before. Although international politics may seem like a universe away, in which people may (erroneously) feel powerless to influence change, our home health care settings can be dramatically improved and humanized by the application of universally accepted humanistic values. Health care, as it is practiced today, is an anachronism at multiple levels. Supportive care in general and psychosocial values specifically offer a more inclusive and realistic alternative. Based on an inclusive staff leadership model, a strategic, hands-on, practical, and compassionate approach to creating and implementing supportive care programs of excellence is described. Finally, potentially fruitful areas in which supportive care and psychosocial values can provide leadership as bridges to more accessible, affordable, and humanistic care are provided for contemplation. Copyright © 2018 John Wiley & Sons, Ltd.

  9. Relations between structural and dynamic thermal characteristics of building walls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kossecka, E.; Kosny, J.

    1996-10-01

    The effect of internal thermal structure on dynamic characteristics of walls is analyzed. The concept of structure factors is introduced and the conditions they impose on response factors are given. Simple examples of multilayer walls, representing different types of thermal resistance and capacity distribution, are analyzed to illustrate general relations between structure factors and response factors. The idea of the ``thermally equivalent wall``, a plane multilayer structure, with dynamic characteristics similar to those of a complex structure, in which three-dimensional heat flow occurs, is presented.

  10. Isotropic thin-walled pressure vessel experiment

    NASA Technical Reports Server (NTRS)

    Denton, Nancy L.; Hillsman, Vernon S.

    1992-01-01

    The objectives are: (1) to investigate the stress and strain distributions on the surface of a thin walled cylinder subject to internal pressure and/or axial load; and (2) to relate stress and strain distributions to material properties and cylinder geometry. The experiment, supplies, and procedure are presented.

  11. Progress, innovation and regulatory science in drug development: the politics of international standard-setting.

    PubMed

    Abraham, John; Reed, Tim

    2002-06-01

    This paper examines international standard-setting in the toxicology of pharmaceuticals during the 1990s, which has involved both the pharmaceutical industry and regulatory agencies in an organization known as the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH). The analysis shows that the relationships between innovation, regulatory science and 'progress' may be more complex and controversial than is often assumed. An assessment of the ICH's claims about the implications of 'technical' harmonization of drug-testing standards for the maintenance of drug safety, via toxicological testing, and the delivery of therapeutic progress, via innovation, is presented. By demonstrating that there is not a technoscientific validity for these claims, it is argued that, within the ICH, a discourse of technological innovation and scientific progress has been used by regulatory agencies and prominent parts of the transnational pharmaceutical industry to legitimize the lowering and loosening of toxicological standards for drug testing. The mobilization and acceptance of this discourse are shown to be pivotal to the ICH's transformation of reductions in safety standards, which are apparently against the interests of patients and public health, into supposed therapeutic benefits derived from promises of greater access to more innovative drug products. The evidence suggests that it is highly implausible that these reductions in the standards of regulatory toxicology are consistent with therapeutic progress for patients, and highlights a worrying aspect embedded in the 'technical trajectories' of regulatory science.

  12. 40 CFR 60.4202 - What emission standards must I meet for emergency engines if I am a stationary CI internal...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emergency engines if I am a stationary CI internal combustion engine manufacturer? 60.4202 Section 60.4202... Combustion Engines Emission Standards for Manufacturers § 60.4202 What emission standards must I meet for emergency engines if I am a stationary CI internal combustion engine manufacturer? (a) Stationary CI...

  13. World Health Organization International Standard to harmonize assays for detection of hepatitis E virus RNA.

    PubMed

    Baylis, Sally A; Blümel, Johannes; Mizusawa, Saeko; Matsubayashi, Keiji; Sakata, Hidekatsu; Okada, Yoshiaki; Nübling, C Micha; Hanschmann, Kay-Martin O

    2013-05-01

    Nucleic acid amplification technique-based assays are a primary method for the detection of acute hepatitis E virus (HEV) infection, but assay sensitivity can vary widely. To improve interlaboratory results for the detection and quantification of HEV RNA, a candidate World Health Organization (WHO) International Standard (IS) strain was evaluated in a collaborative study involving 23 laboratories from 10 countries. The IS, code number 6329/10, was formulated by using a genotype 3a HEV strain from a blood donation, diluted in pooled human plasma and lyophilized. A Japanese national standard, representing a genotype 3b HEV strain, was prepared and evaluated in parallel. The potencies of the standards were determined by qualitative and quantitative assays. Assay variability was substantially reduced when HEV RNA concentrations were expressed relative to the IS. Thus, WHO has established 6329/10 as the IS for HEV RNA, with a unitage of 250,000 International Units per milliliter.

  14. Moisture Management for High R-Value Walls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lepage, R.; Schumacher, C.; Lukachko, A.

    2013-11-01

    The following report explains the moisture-related concerns for High R-value wall assemblies and discusses past Building America research work that informs this study. Hygrothermal simulations were prepared for several common approaches to High R-value wall construction in six cities (Houston, Atlanta, Seattle, St. Louis, Chicago, and International Falls) representing a range of climate zones (2, 3, 4C, 4, 5A, and 7, respectively). The simulations are informed by experience gained from past research in this area and validated by field measurement and forensic experience. The modeling program was developed to assess the moisture durability of the wall assemblies based on threemore » primary sources of moisture: construction moisture, air leakage condensation, and bulk water leakage. The peak annual moisture content of the wood based exterior sheathing was used to comparatively analyze the response to the moisture loads for each of the walls in each given city. Walls which experienced sheathing moisture contents between 20% and 28% were identified as risky, whereas those exceeding 28% were identified as very high risk. All of the wall assemblies perform well under idealized conditions. However, only the walls with exterior insulation, or cavity insulation which provides a hygrothermal function similar to exterior insulation, perform adequately when exposed to moisture loads. Walls with only cavity insulation are particularly susceptible to air leakage condensation. None of the walls performed well when a precipitation based bulk water leak was introduced to the backside of the sheathing, emphasizing the importance of proper flashing details.« less

  15. Evaluation of Vocational Services Provided to Jordanian Disabled People According to International Standards

    ERIC Educational Resources Information Center

    Al-Oweidi, Alia

    2015-01-01

    The purpose of the study is to evaluate the vocational rehabilitation services provided to people with disabilities according to international standards in Jordan. The sample of the study consisted of (56) managers and teachers in four specialized centers in vocational rehabilitation. The findings showed that the compatibility degree ranged…

  16. 76 FR 68829 - International Standards on the Transport of Dangerous Goods; Public Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-07

    .... PHMSA-2011-0246; Notice No. 11-11] International Standards on the Transport of Dangerous Goods; Public... of Experts on the Transport of Dangerous Goods (UNSCOE TDG) to be held November 28 to December 7... on the Transport of Dangerous Goods Model Regulations which will be implemented within relevant...

  17. International Review of Standards and Labeling Programs for Distribution Transformers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Letschert, Virginie; Scholand, Michael; Carreño, Ana María

    Transmission and distribution (T&D) losses in electricity networks represent 8.5% of final energy consumption in the world. In Latin America, T&D losses range between 6% and 20% of final energy consumption, and represent 7% in Chile. Because approximately one-third of T&D losses take place in distribution transformers alone, there is significant potential to save energy and reduce costs and carbon emissions through policy intervention to increase distribution transformer efficiency. A large number of economies around the world have recognized the significant impact of addressing distribution losses and have implemented policies to support market transformation towards more efficient distribution transformers. Asmore » a result, there is considerable international experience to be shared and leveraged to inform countries interested in reducing distribution losses through policy intervention. The report builds upon past international studies of standards and labeling (S&L) programs for distribution transformers to present the current energy efficiency programs for distribution transformers around the world.« less

  18. [The revised Dutch College of General Practitioners' standard on COPD and the first international WHO standard: differences and similarities].

    PubMed

    van Schayck, C P

    2002-02-23

    Two standards on COPD have recently been published: the revised national standard from the Dutch College of General Practitioners and the first international standard published by the World Health Organization and the US National Heart, Lung and Blood Institute. The reduced emphasis on the role of spirometry in the monitoring and evaluation of treatment is an important change in these new standards compared to previous ones. Cessation of smoking is considered to be central to the prevention and treatment of COPD. Doctors should strongly support this approach and, more than before, are urged to view COPD as a disease caused by addiction. Bronchodilators are the cornerstone of symptomatic treatment of COPD, particularly the long-acting ones due to their ease of administration and effective treatment of morning dyspnoea. Inhalation corticosteroids should only be administered as a trial treatment and only under certain conditions. Continuation of treatment with these agents is only justified if there is a demonstrated improvement in lung function, exacerbations or symptoms, although the precise area of indication is not yet clear.

  19. A Near-Wall Reynolds-Stress Closure Without Wall Normals

    NASA Technical Reports Server (NTRS)

    Yuan, S. P.; So, R. M. C.

    1997-01-01

    Turbulent wall-bounded complex flows are commonly encountered in engineering practice and are of considerable interest in a variety of industrial applications. The presence of a wall significantly affects turbulence characteristics. In addition to the wall effects, turbulent wall-bounded flows become more complicated by the presence of additional body forces (e.g. centrifugal force and Coriolis force) and complex geometry. Most near-wall Reynolds stress models are developed from a high-Reynolds-number model which assumes turbulence is homogenous (or quasi-homogenous). Near-wall modifications are proposed to include wall effects in near-wall regions. In this process, wall normals are introduced. Good predictions could be obtained by Reynolds stress models with wall normals. However, ambiguity arises when the models are applied in flows with multiple walls. Many models have been proposed to model turbulent flows. Among them, Reynolds stress models, in which turbulent stresses are obtained by solving the Reynolds stress transport equations, have been proved to be the most successful ones. To apply the Reynolds stress models to wall-bounded flows, near-wall corrections accounting for the wall effects are needed, and the resulting models are called near-wall Reynolds stress models. In most of the existing near-wall models, the near-wall corrections invoke wall normals. These wall-dependent near-wall models are difficult to implement for turbulent flows with complex geometry and may give inaccurate predictions due to the ambiguity of wall normals at corners connecting multiple walls. The objective of this study is to develop a more general and flexible near-wall Reynolds stress model without using any wall-dependent variable for wall-bounded turbulent flows. With the aid of near-wall asymptotic analysis and results of direct numerical simulation, a new near-wall Reynolds stress model (NNWRS) is formulated based on Speziale et al.'s high-Reynolds-stress model with wall

  20. Fluorescein thiocarbamyl amino acids as internal standards for migration time correction in capillary sieving electrophoresis

    PubMed Central

    Pugsley, Haley R.; Swearingen, Kristian E.; Dovichi, Norman J.

    2009-01-01

    A number of algorithms have been developed to correct for migration time drift in capillary electrophoresis. Those algorithms require identification of common components in each run. However, not all components may be present or resolved in separations of complex samples, which can confound attempts for alignment. This paper reports the use of fluorescein thiocarbamyl derivatives of amino acids as internal standards for alignment of 3-(2-furoyl)quinoline-2-carboxaldehyde (FQ)-labeled proteins in capillary sieving electrophoresis. The fluorescein thiocarbamyl derivative of aspartic acid migrates before FQ-labeled proteins and the fluorescein thiocarbamyl derivative of arginine migrates after the FQ-labeled proteins. These compounds were used as internal standards to correct for variations in migration time over a two-week period in the separation of a cellular homogenate. The experimental conditions were deliberately manipulated by varying electric field and sample preparation conditions. Three components of the homogenate were used to evaluate the alignment efficiency. Before alignment, the average relative standard deviation in migration time for these components was 13.3%. After alignment, the average relative standard deviation in migration time for these components was reduced to 0.5%. PMID:19249052

  1. Coherent structures in wall-bounded turbulence

    NASA Astrophysics Data System (ADS)

    Jiménez, Javier

    2018-05-01

    This article discusses the description of wall-bounded turbulence as a deterministic high-dimensional dynamical system of interacting coherent structures, defined as eddies with enough internal dynamics to behave relatively autonomously from any remaining incoherent part of the flow. The guiding principle is that randomness is not a property, but a methodological choice of what to ignore in the flow, and that a complete understanding of turbulence, including the possibility of control, requires that it be kept to a minimum. After briefly reviewing the underlying low-order statistics of flows at moderate Reynolds numbers, the article examines what two-point statistics imply for the decomposition of the flow into individual eddies. Intense eddies are examined next, including their temporal evolution, and shown to satisfy many of the properties required for coherence. In particular, it is shown that coherent structures larger than the Corrsin scale are a natural consequence of the shear. In wall-bounded turbulence, they can be classified into coherent dispersive waves and transient bursts. The former are found in the viscous layer near the wall and as very-large structures spanning the boundary layer thickness. Although they are shear-driven, these waves have enough internal structure to maintain a uniform advection velocity. Conversely, bursts exist at all scales, are characteristic of the logarithmic layer, and interact almost linearly with the shear. While the waves require a wall to determine their length scale, the bursts are essentially independent from it. The article concludes with a brief review of our present theoretical understanding of turbulent structures, and with a list of open problems and future perspectives.

  2. The Effect of International Financial Reporting Standards Convergence on U. S. Accounting Curriculum

    ERIC Educational Resources Information Center

    Bates, Homer L.; Waldrup, Bobby E.; Shea, Vincent

    2011-01-01

    Major changes are coming to U.S. financial accounting and accounting education as U. S. generally accepted accounting principles (GAAP) and international financial reporting standards (IFRS) converge within the next few years. In 2008, the U.S. Securities and Exchange Commission (SEC) published a proposed "road map" for the potential…

  3. Guide to International Academic Standards for Athletics Eligibility for Students Entering Fall 2007

    ERIC Educational Resources Information Center

    Mills, Lisa; Nguyen, Binh; Auten, Lisa

    2007-01-01

    The "NCAA Guide to International Academic Standards for Athletics Eligibility" provides specific criteria to be used as a guide in reviewing the initial eligibility (graduation, core curriculum, grade-point average and ACT/SAT test scores) of students who have completed any portion of their secondary education in a non-United States…

  4. 77 FR 69927 - International Standards on the Transport of Dangerous Goods; Public Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-21

    .... PHMSA-2012-0247; Notice No. 12-09] International Standards on the Transport of Dangerous Goods; Public... of Experts on the Transport of Dangerous Goods (UNSCOE TDG) to be held December 3 to 11, 2012, in... Edition of the United Nations Recommendations on the Transport of Dangerous Goods Model Regulations which...

  5. Media Representations of National and International Standardized Testing in the Israeli Education System

    ERIC Educational Resources Information Center

    Yemini, Miri; Gordon, Noa

    2017-01-01

    This study applies discourse analysis to Israeli media coverage of national and international standardized examinations within Israel's public education system. Through systematic analysis of the topic in the two main Israeli financial publications between the years 2000 and 2013, we explore the nature and narrative of the media and compare the…

  6. Enabling conformity to international standards within SeaDataNet

    NASA Astrophysics Data System (ADS)

    Schaap, Dick M. A.; Boldrini, Enrico; de Korte, Arjen; Santoro, Mattia; Manzella, Giuseppe; Nativi, Stefano

    2010-05-01

    SeaDataNet objective is to construct a standardized system for managing the large and diverse data sets collected by the oceanographic fleets and the new automatic observation systems. The aim is to network and enhance the currently existing infrastructures, which are the national oceanographic data centres and satellite data centres of 36 countries, active in data collection. The networking of these professional data centres, in a unique virtual data management system will provide integrated data sets of standardized quality on-line. The Common Data Index (CDI) is the middleware service adopted by SeaDataNet for discovery and access of the available data. In order to develop an interoperable and effective system, the use of international de facto and de jure standards is required. In particular the new goal object of this presentation is to introduce and discuss the solutions for making SeaDataNet compliant with the European Union (EU) INSPIRE directive and in particular with its Implementing Rules (IR). The European INSPIRE directive aims to rule the creation of an European Spatial Data Infrastructure (ESDI). This will enable the sharing of environmental spatial information among public sector organisations and better facilitate public access to spatial information across Europe. To ensure that the spatial data infrastructures of the European Member States are compatible and usable in a community and transboundary context, the directive requires that common IRs are adopted in a number of specific areas (Metadata, Data Specifications, Network Services, Data and Service Sharing and Monitoring and Reporting). Often the use of already approved digital geographic information standards is mandated, drawing from international organizations like the Open Geospatial Consortium (OGC) and the International Organization for Standardization (ISO), the latter by means of its Technical Committee 211 (ISO/TC 211). In the context of geographic data discovery a set of mandatory

  7. Application of ISO standard 27048: dose assessment for the monitoring of workers for internal radiation exposure.

    PubMed

    Henrichs, K

    2011-03-01

    Besides ongoing developments in the dosimetry of incorporated radionuclides, there are various efforts to improve the monitoring of workers for potential or real intakes of radionuclides. The disillusioning experience with numerous intercomparison projects identified substantial differences between national regulations, concepts, applied programmes and methods, and dose assessment procedures. Measured activities were not directly comparable because of significant differences between measuring frequencies and methods, but also results of case studies for dose assessments revealed differences of orders of magnitude. Besides the general common interest in reliable monitoring results, at least the cross-border activities of workers (e.g. nuclear power plant services) require consistent approaches and comparable results. The International Standardization Organization therefore initiated projects to standardise programmes for the monitoring of workers, the requirements for measuring laboratories and the processes for the quantitative evaluation of monitoring results in terms of internal assessed doses. The strength of the concepts applied by the international working group consists in a unified approach defining the requirements, databases and processes. This paper is intended to give a short introduction into the standardization project followed by a more detailed description of the dose assessment standard, which will be published in the very near future.

  8. Characterizing phenolformaldehyde adhesive cure chemistry within the wood cell wall

    Treesearch

    Daniel J. Yelle; John Ralph

    2016-01-01

    Adhesive bonding of wood using phenol-formaldehyde remains the industrial standard in wood product bond durability. Not only does this adhesive infiltrate the cell wall, it also is believed to form primary bonds with wood cell wall polymers, particularly guaiacyl lignin. However, the mechanism by which phenol-formaldehyde adhesive intergrally interacts and bonds to...

  9. 75 FR 6070 - Notice of Public Meeting on the International Atomic Energy Agency Basic Safety Standards Version...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-05

    ... Energy Agency Basic Safety Standards Version 3.0, Draft Safety Requirements DS379 AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Public Meeting on the International Atomic Energy Agency Basic... development of U.S. Government comments on this International Atomic Energy Agency (IAEA) draft General Safety...

  10. Shoulder kinematics during the wall push-up plus exercise.

    PubMed

    Lunden, Jason B; Braman, Jonathan P; Laprade, Robert F; Ludewig, Paula M

    2010-03-01

    The push-up plus exercise is a common therapeutic exercise for improving shoulder function and treating shoulder pathology. To date, the kinematics of the push-up plus exercise have not been studied. Our hypothesis was that the wall push-up plus exercise would demonstrate increased scapular internal rotation and increased humeral anterior translation during the plus phase of the exercise, thereby potentially impacting the subacromial space. Bone pins were inserted in the humerus and scapula in 12 healthy volunteers with no history of shoulder pathology. In vivo motion during the wall push-up plus exercise was tracked using an electromagnetic tracking system. During the wall push-up plus exercise, from a starting position to the push-up plus position, there was a significant increase in scapular downward rotation (P < .05) and internal rotation (P < .05). The pattern of glenohumeral motion was humeral elevation (P < .05) and movement anterior to the scapular plane (P < .05), with humeral external rotation remaining relatively constant. We found that during a wall push-up plus exercise in healthy volunteers, the scapula was placed in a position potentially associated with shoulder impingement. Because of the shoulder kinematics of the wall push-up plus exercise, utilization of this exercise without modification early on in shoulder rehabilitation, especially in patients with subacromial impingement, should be considered cautiously. Copyright 2010 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  11. Atypical anterior wall fracture of the acetabulum: case series of anterior acetabular rim fracture without involvement of the pelvic brim.

    PubMed

    Lenarz, Christopher J; Moed, Berton R

    2007-09-01

    The purpose of this study was to describe a form of anterior wall acetabular fracture, which has been inadequately defined in the literature. Retrospective analysis of consecutive patients. Level 1 trauma center. A retrospective analysis of consecutive acetabulum patients treated by a single surgeon between 1999 and 2005 identified 6 patients with a form of anterior wall fracture without involvement of the pelvic brim. All fractures were treated operatively. Open reduction and internal fixation through an anterior surgical approach. Final radiographic appearance and modified Merle d'Aubigne score. All 6 cases demonstrated characteristics of an atypical fracture of the anterior wall, involving the anterior rim of the acetabulum similar in nature to those described for the posterior wall, rather than the standard anterior wall fracture type described by Letournel. Of the 6 cases that were identified, 5 had follow-up 1 year or greater with a mean modified Merle d'Aubigne Score of 17 (range: 17-18). A form of anterior wall acetabular fracture exists, which involves the anterior acetabular rim without involvement of the pelvic brim. It can occur in young patients with high-energy mechanisms of injury, as well as in the elderly with low-energy trauma. With appropriate surgical management, using a modified Smith-Peterson approach, good to excellent clinical outcomes should be expected.

  12. 77 FR 33019 - International Standards on the Transport of Dangerous Goods; Public Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-04

    .... PHMSA-2012-0116; Notice No. 12-6] International Standards on the Transport of Dangerous Goods; Public... of Experts on the Transport of Dangerous Goods (UNSCOE TDG) to be held June 25 to July 4, 2012, in... consider proposals for the 18th Revised Edition of the United Nations Recommendations on the Transport of...

  13. Open System Interconnection - NASA program communications of the future. [developed by International aorganization for Standardization

    NASA Technical Reports Server (NTRS)

    Brady, Charles D.

    1987-01-01

    Open Systems Interconnection (OSI) standards are being developed by the ISO and the Consultative Committee on International Telephone and Telegraph with the support of industry. These standards are being developed to allow the interconnecting of computer systems and the interworking of applications such that the applications can be independent of any equipment manufacturer. Significant progress has been made, and the establishment of government OSI standards is being considered. There is considerable interest within NASA in the potential benefits of OSI and in communications standards in general. The OSI standards are being considered for possible application in the Space Station onboard data management system. The OSI standards have reached a high level of maturity, and it is now imperative that NASA plan for future migration to OSI where appropriate.

  14. International longitudinal pediatric reference standards for bone mineral content.

    PubMed

    Baxter-Jones, Adam D G; Burrows, Melonie; Bachrach, Laura K; Lloyd, Tom; Petit, Moira; Macdonald, Heather; Mirwald, Robert L; Bailey, Don; McKay, Heather

    2010-01-01

    To render a diagnosis pediatricians rely upon reference standards for bone mineral density or bone mineral content, which are based on cross-sectional data from a relatively small sample of children. These standards are unable to adequately represent growth in a diverse pediatric population. Thus, the goal of this study was to develop sex and site-specific standards for BMC using longitudinal data collected from four international sites in Canada and the United States. Data from four studies were combined; Saskatchewan Paediatric Bone Mineral Accrual Study (n=251), UBC Healthy Bones Study (n=382); Penn State Young Women's Health Study (n=112) and Stanford's Bone Mineral Accretion study (n=423). Males and females (8 to 25 years) were measured for whole body (WB), total proximal femur (PF), femoral neck (FN) and lumbar spine (LS) BMC (g). Data were analyzed using random effects models. Bland-Altman was used to investigate agreement between predicted and actual data. Age, height, weight and ethnicity independently predicted BMC accrual across sites (P<0.05). Compared to White males, Asian males had 31.8 (6.8) g less WB BMC accrual; Hispanic 75.4 (28.2) g less BMC accrual; Blacks 82.8 (26.3) g more BMC accrual with confounders of age, height and weight controlled. We report similar findings for the PF and FN. Models for females for all sites were similar with age, height and weight as independent significant predictors of BMC accrual (P<0.05). We provide a tool to calculate a child's BMC Z-score, accounting for age, size, sex and ethnicity. In conclusion, when interpreting BMC in pediatrics we recommend standards that are sex, age, size and ethnic specific. Copyright (c) 2009 Elsevier Inc. All rights reserved.

  15. International Longitudinal Paediatric Reference Standards for Bone Mineral Content

    PubMed Central

    Baxter-Jones, Adam DG; McKay, Heather; Burrows, Melonie; Bachrach, Laura K; Lloyd, Tom; Petit, Moira; Macdonald, Heather; Mirwald, Robert L; Bailey, Don

    2014-01-01

    To render a diagnosis pediatricians rely upon reference standards for bone mineral density or bone mineral content, which are based on cross-sectional data from a relatively small sample of children. These standards are unable to adequately represent growth in a diverse pediatric population. Thus, the goal of this study was to develop sex and site specific standards for BMC using longitudinal data collected from four international sites in Canada and the United States. Data from four studies were combined; Saskatchewan Paediatric Bone Mineral Accrual Study (n=251), UBC Healthy Bones Study (n=382); Penn State Young Women’s Health Study (n=112) and Stanford’s Bone Mineral Accretion study (n=423). Males and females (8 to 25 years) were measured for whole body (WB), total proximal femur (PF), femoral neck (FN) and lumbar spine (LS) BMC (g). Data were analyzed using random effects models. Bland-Altman was used to investigate agreement in predicted and actual data. Age, height, weight and ethnicity independently predicted BMC accrual across sites (P <0.05). Compared to White males, Asian males had 31.8 (6.8) g less WB BMC accrual; Hispanic 75.4 (28.2) g less BMC accrual; Blacks 82.8 (26.3) g more BMC accrual with confounders of age, height and weight controlled. Similar findings were found for PF and FN. Female models for all sites were similar with age, height and weight all independent significant predictors of BMC accrual (P <0.05). We provide a tool to calculate a child’s BMC Z-score, accounting for age, size, sex and ethnicity. In conclusion, when interpreting BMC in paediatrics we recommend standards that are sex, age, size and ethnic specific. PMID:19854308

  16. Differences in Students' Reading Comprehension of International Financial Reporting Standards: A South African Case

    ERIC Educational Resources Information Center

    Coetzee, Stephen A.; Janse van Rensburg, Cecile; Schmulian, Astrid

    2016-01-01

    This study explores differences in students' reading comprehension of International Financial Reporting Standards in a South African financial reporting class with a heterogeneous student cohort. Statistically significant differences were identified for prior academic performance, language of instruction, first language and enrolment in the…

  17. Rotation in a reversed field pinch with active feedback stabilization of resistive wall modes

    NASA Astrophysics Data System (ADS)

    Cecconello, M.; Menmuir, S.; Brunsell, P. R.; Kuldkepp, M.

    2006-09-01

    Active feedback stabilization of multiple resistive wall modes (RWMs) has been successfully proven in the EXTRAP T2R reversed field pinch. One of the features of plasma discharges operated with active feedback stabilization, in addition to the prolongation of the plasma discharge, is the sustainment of the plasma rotation. Sustained rotation is observed both for the internally resonant tearing modes (TMs) and the intrinsic impurity oxygen ions. Good quantitative agreement between the toroidal rotation velocities of both is found: the toroidal rotation is characterized by an acceleration phase followed, after one wall time, by a deceleration phase that is slower than in standard discharges. The TMs and the impurity ions rotate in the same poloidal direction with also similar velocities. Poloidal and toroidal velocities have comparable amplitudes and a simple model of their radial profile reproduces the main features of the helical angular phase velocity. RWMs feedback does not qualitatively change the TMs behaviour and typical phenomena such as the dynamo and the 'slinky' are still observed. The improved sustainment of the plasma and TMs rotation occurs also when feedback only acts on internally non-resonant RWMs. This may be due to an indirect positive effect, through non-linear coupling between TMs and RWMs, of feedback on the TMs or to a reduced plasma-wall interaction affecting the plasma flow rotation. Electromagnetic torque calculations show that with active feedback stabilization the TMs amplitude remains well below the locking threshold condition for a thick shell. Finally, it is suggested that active feedback stabilization of RWMs and current profile control techniques can be employed simultaneously thus improving both the plasma duration and its confinement properties.

  18. Traction reveals mechanisms of wall effects for microswimmers near boundaries

    NASA Astrophysics Data System (ADS)

    Shen, Xinhui; Marcos, Fu, Henry C.

    2017-03-01

    The influence of a plane boundary on low-Reynolds-number swimmers has frequently been studied using image systems for flow singularities. However, the boundary effect can also be expressed using a boundary integral representation over the traction on the boundary. We show that examining the traction pattern on the boundary caused by a swimmer can yield physical insights into determining when far-field multipole models are accurate. We investigate the swimming velocities and the traction of a three-sphere swimmer initially placed parallel to an infinite planar wall. In the far field, the instantaneous effect of the wall on the swimmer is well approximated by that of a multipole expansion consisting of a force dipole and a force quadrupole. On the other hand, the swimmer close to the wall must be described by a system of singularities reflecting its internal structure. We show that these limits and the transition between them can be independently identified by examining the traction pattern on the wall, either using a quantitative correlation coefficient or by visual inspection. Last, we find that for nonconstant propulsion, correlations between swimming stroke motions and internal positions are important and not captured by time-averaged traction on the wall, indicating that care must be taken when applying multipole expansions to study boundary effects in cases of nonconstant propulsion.

  19. Traction reveals mechanisms of wall effects for microswimmers near boundaries.

    PubMed

    Shen, Xinhui; Marcos; Fu, Henry C

    2017-03-01

    The influence of a plane boundary on low-Reynolds-number swimmers has frequently been studied using image systems for flow singularities. However, the boundary effect can also be expressed using a boundary integral representation over the traction on the boundary. We show that examining the traction pattern on the boundary caused by a swimmer can yield physical insights into determining when far-field multipole models are accurate. We investigate the swimming velocities and the traction of a three-sphere swimmer initially placed parallel to an infinite planar wall. In the far field, the instantaneous effect of the wall on the swimmer is well approximated by that of a multipole expansion consisting of a force dipole and a force quadrupole. On the other hand, the swimmer close to the wall must be described by a system of singularities reflecting its internal structure. We show that these limits and the transition between them can be independently identified by examining the traction pattern on the wall, either using a quantitative correlation coefficient or by visual inspection. Last, we find that for nonconstant propulsion, correlations between swimming stroke motions and internal positions are important and not captured by time-averaged traction on the wall, indicating that care must be taken when applying multipole expansions to study boundary effects in cases of nonconstant propulsion.

  20. Using three dimensional silicone ``boots`` to solve complex remedial design problems in curtain walls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Y.J.

    1998-12-31

    Stick system curtain wall leak problems are frequently caused by water entry at the splice joints of the curtain wall frame and failure of the internal metal joinery seals. Remedial solutions involving occupied buildings inevitably face the multiple constraints of existing construction and business operations not present during the original curtain wall construction. In most cases, even partial disassembly of the curtain wall for internal seal repairs is not feasible. Remedial solutions which must be executed from the exterior of the curtain wall often involve wet-applied or preformed sealant tape bridge joints. However, some of the more complex joints cannotmore » be repaired effectively or economically with the conventional bridge joint. Fortunately, custom fabricated three-dimensional preformed sealant boots are becoming available to address these situations. This paper discusses the design considerations and the selective use of three-dimensional preformed boots in sealing complex joint geometry that would not be effective with the conventional two-dimensional bridge joint.« less

  1. Competitor internal standards for quantitative detection of mycoplasma DNA.

    PubMed

    Sidhu, M K; Rashidbaigi, A; Testa, D; Liao, M J

    1995-05-01

    Homologous internal controls were used as competitor DNA in the polymerase chain reaction for the quantitative detection of mycoplasma DNA. PCR primer sets were designed on the basis of the most conserved nucleotide sequences of the 16S rRNA gene of mycoplasma species. Amplification of this gene was examined in five different mycoplasma species: Mycoplasma orale, M. hyorhinus, M. synoviae, M. gallisepticum and M. pneumoniae. To evaluate the primers, a number of different cell lines were assayed for the detection of mycoplasma infections. All positive cell lines showed a distinct product on agarose gels while uninfected cells showed no DNA amplification. Neither bacterial nor eukaryotic DNA produced any cross-reaction with the primers used, thus confirming their specificity. Internal control DNA to be used for quantitation was constructed by modifying the sizes of the wild-type amplified products and cloning them in plasmid vectors. These controls used the same primer binding sites as the wild-type and the amplified products were differentiated by a size difference. The detection limits for all the mycoplasma species by competitive quantitative PCR were estimated to range from 4 to 60 genome copies per assay as determined by ethidium bromide-stained agarose gels. These internal standards also serve as positive controls in PCR-based detection of mycoplasma DNA, and therefore accidental contamination of test samples with wild-type positive controls can be eliminated. The quantitative PCR method developed will be useful in monitoring the progression and significance of mycoplasma in the disease process.

  2. Wall conditioning and particle control in Extrap T2

    NASA Astrophysics Data System (ADS)

    Bergsåker, H.; Larsson, D.; Brunsell, P.; Möller, A.; Tramontin, L.

    1997-02-01

    The Extrap T2 reversed field pinch experiment is operated with the former OHTE vacuum vessel, of dimensions R = 1.24 m and a = 0.18 m and with a complete graphite liner. It is shown that a rudimentary density control can be achieved by means of frequent helium glow discharge conditioning of the wall. The standard He-GDC is well characterized and reproducible. The trapping and release of hydrogen and impurities at the wall surfaces have been studied by mass spectrometry and surface analysis. The shot to shot particle exchange between wall and plasma can be approximately accounted for.

  3. International Standards for Tuberculosis Care: revisiting the cornerstones of tuberculosis care and control.

    PubMed

    Fair, Elizabeth; Hopewell, Philip C; Pai, Madhukar

    2007-02-01

    Tuberculosis (TB) remains an enormous global health problem. There are 8-9 million new cases and 2 million deaths from TB annually. Despite the overwhelming burden of disease, the basic principles of care for persons with, or suspected of having, TB are the same worldwide: a diagnosis should be established promptly and accurately, standardized treatment regimens of proven efficacy should be used together with appropriate treatment support and supervision, the response to treatment should be monitored, and the essential public health responsibilities must be carried out. As an approach to improving the care of patients with TB, an evidence-based document, the International Standards for Tuberculosis Care (ISTC) was developed and has been endorsed by more than 30 international and national agencies. This special report introduces the ISTC and discusses the fact that accurate diagnosis and effective treatment are not only essential for good patient care, they are the key elements in the public health response to TB and are the cornerstone of TB control. With the recent emergence of extensively drug-resistant TB, there is an urgent need to ensure globally that standards of TB care are based on rigorous scientific findings, are clear and well understood, and are accessible to and applied by all types of healthcare providers in all corners of the world.

  4. A novel reductive amination method with isotopic formaldehydes for the preparation of internal standard and standards for determining organosulfur compounds in garlic.

    PubMed

    Tsai, De-Cheng; Liu, Meng-Chieh; Lin, Yi-Reng; Huang, Mei-Fang; Liang, Shih-Shin

    2016-04-15

    Garlic (Allium sativum) is a long-cultivated plant that is widely utilized in cooking and has been employed as a medicine for over 4000 years. In this study, we fabricated standards and internal standards (ISs) for absolute quantification via reductive amination with isotopic formaldehydes. Garlic has four abundant organosulfur compounds (OSCs): S-allylcysteine, S-allylcysteinine sulfoxide, S-methylcysteine, and S-ethylcysteine are abundant in garlic. OSCs with primary amine groups were reacted with isotopic formaldehydes to synthesize ISs and standards. Cooked and uncooked garlic samples were compared, and we utilized tandem mass spectrometry equipped with a selective reaction monitoring technique to absolutely quantify the four organosulfur compounds. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. 77 FR 1915 - Light-Walled Rectangular Pipe and Tube From Mexico; Final Results of Antidumping Duty...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-12

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-201-836] Light-Walled Rectangular... preliminary results of the administrative review of the antidumping duty order on light-walled rectangular... period of review (POR) from August 1, 2009, through July 31, 2010. \\1\\ See Light-Walled Rectangular Pipe...

  6. 77 FR 5240 - Light-Walled Welded Rectangular Carbon Steel Tubing From Taiwan: Continuation of Antidumping Duty...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-02

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-583-803] Light-Walled Welded... revocation of the antidumping duty order on light-walled welded rectangular carbon steel tubing from Taiwan..., and the ITC instituted, the sunset review of the antidumping duty order \\1\\ on light-walled welded...

  7. International standardization of cage designs and feeding regimes for honey bee in vitro experiments

    USDA-ARS?s Scientific Manuscript database

    The aim of this study was to improve and standardize cage systems for maintaining adult honey bee workers under in vitro laboratory conditions. To achieve this goal, we experimentally evaluated the impact of different cages, developed by scientists of the international research network COLOSS (Preve...

  8. Prevalence of Overweight and Obesity among Female Adolescents in Jordan: A comparison between Two International Reference Standards

    PubMed Central

    O. Musaiger, Abdulrahman; Al-Mannai, Mariam; Tayyem, Reema

    2013-01-01

    Objective: To find out the prevalence of overweight and obesity among female adolescents in Jordan. Methodology: A cross-sectional survey on females aged 15–18 in Amman, Jordan, was carried out using a multistage stratified random sampling method. The total sample size was 475 girls. Weight and height were measured and body mass index for age was used to determine overweight and obesity using the IOTF and WHO international standards. Results: The prevalence of overweight and obesity decreased with age. The highest prevalence of overweight and obesity was reported at age 15 (24.4% and 8.9%, respectively). The WHO standard showed a higher prevalence of obesity than the IOTF standard in all age groups. Conclusions: Overweight and obesity are serious public health problems among adolescents in Jordan, using both international standards. A program to combat obesity among schoolchildren, therefore, should be given a high priority in school health policy in Jordan. PMID:24353605

  9. Recommendations for reference method for haemoglobinometry in human blood (ICSH standard 1986) and specifications for international haemiglobincyanide reference preparation (3rd edition). International Committee for Standardization in Haematology; Expert Panel on Haemoglobinometry.

    PubMed

    1987-01-01

    Scientific symposia on haemoglobinometry were held at the 9th Congress of the European Society of Haematology, Lisbon, 1963 (ESH 1964) and the 10th Congress of the International Society of Haematology (ISH), Stockholm, 1964 (ISH 1965). The International Committee for Standardization in Haematology (ICSH) made recommendations endorsed by the General Assembly of ICSH in Sydney on 23 August 1966 (ICSH 1967), for a reference method for haemoglobinometry and for the manufacture and distribution of an international reference preparation. Further symposia were held at the 12th Congress of the ISH, New York, 1968 (Astaldi, Sirtori & Vanzetti 1979) and at the 13th Congress of ISH, Munich, 1970 (Izak & Lewis 1972). The recommendations were reissued in 1978 (ISH 1978). On the basis of continuing experimental studies, the reference method and the specifications for the international reference preparation have been modified. The revised recommendations are described in this document.

  10. Standardizing clinical trials workflow representation in UML for international site comparison.

    PubMed

    de Carvalho, Elias Cesar Araujo; Jayanti, Madhav Kishore; Batilana, Adelia Portero; Kozan, Andreia M O; Rodrigues, Maria J; Shah, Jatin; Loures, Marco R; Patil, Sunita; Payne, Philip; Pietrobon, Ricardo

    2010-11-09

    With the globalization of clinical trials, a growing emphasis has been placed on the standardization of the workflow in order to ensure the reproducibility and reliability of the overall trial. Despite the importance of workflow evaluation, to our knowledge no previous studies have attempted to adapt existing modeling languages to standardize the representation of clinical trials. Unified Modeling Language (UML) is a computational language that can be used to model operational workflow, and a UML profile can be developed to standardize UML models within a given domain. This paper's objective is to develop a UML profile to extend the UML Activity Diagram schema into the clinical trials domain, defining a standard representation for clinical trial workflow diagrams in UML. Two Brazilian clinical trial sites in rheumatology and oncology were examined to model their workflow and collect time-motion data. UML modeling was conducted in Eclipse, and a UML profile was developed to incorporate information used in discrete event simulation software. Ethnographic observation revealed bottlenecks in workflow: these included tasks requiring full commitment of CRCs, transferring notes from paper to computers, deviations from standard operating procedures, and conflicts between different IT systems. Time-motion analysis revealed that nurses' activities took up the most time in the workflow and contained a high frequency of shorter duration activities. Administrative assistants performed more activities near the beginning and end of the workflow. Overall, clinical trial tasks had a greater frequency than clinic routines or other general activities. This paper describes a method for modeling clinical trial workflow in UML and standardizing these workflow diagrams through a UML profile. In the increasingly global environment of clinical trials, the standardization of workflow modeling is a necessary precursor to conducting a comparative analysis of international clinical trials

  11. Standardizing Clinical Trials Workflow Representation in UML for International Site Comparison

    PubMed Central

    de Carvalho, Elias Cesar Araujo; Jayanti, Madhav Kishore; Batilana, Adelia Portero; Kozan, Andreia M. O.; Rodrigues, Maria J.; Shah, Jatin; Loures, Marco R.; Patil, Sunita; Payne, Philip; Pietrobon, Ricardo

    2010-01-01

    Background With the globalization of clinical trials, a growing emphasis has been placed on the standardization of the workflow in order to ensure the reproducibility and reliability of the overall trial. Despite the importance of workflow evaluation, to our knowledge no previous studies have attempted to adapt existing modeling languages to standardize the representation of clinical trials. Unified Modeling Language (UML) is a computational language that can be used to model operational workflow, and a UML profile can be developed to standardize UML models within a given domain. This paper's objective is to develop a UML profile to extend the UML Activity Diagram schema into the clinical trials domain, defining a standard representation for clinical trial workflow diagrams in UML. Methods Two Brazilian clinical trial sites in rheumatology and oncology were examined to model their workflow and collect time-motion data. UML modeling was conducted in Eclipse, and a UML profile was developed to incorporate information used in discrete event simulation software. Results Ethnographic observation revealed bottlenecks in workflow: these included tasks requiring full commitment of CRCs, transferring notes from paper to computers, deviations from standard operating procedures, and conflicts between different IT systems. Time-motion analysis revealed that nurses' activities took up the most time in the workflow and contained a high frequency of shorter duration activities. Administrative assistants performed more activities near the beginning and end of the workflow. Overall, clinical trial tasks had a greater frequency than clinic routines or other general activities. Conclusions This paper describes a method for modeling clinical trial workflow in UML and standardizing these workflow diagrams through a UML profile. In the increasingly global environment of clinical trials, the standardization of workflow modeling is a necessary precursor to conducting a comparative

  12. Reliable LC-MS quantitative glycomics using iGlycoMab stable isotope labeled glycans as internal standards.

    PubMed

    Zhou, Shiyue; Tello, Nadia; Harvey, Alex; Boyes, Barry; Orlando, Ron; Mechref, Yehia

    2016-06-01

    Glycans have numerous functions in various biological processes and participate in the progress of diseases. Reliable quantitative glycomic profiling techniques could contribute to the understanding of the biological functions of glycans, and lead to the discovery of potential glycan biomarkers for diseases. Although LC-MS is a powerful analytical tool for quantitative glycomics, the variation of ionization efficiency and MS intensity bias are influencing quantitation reliability. Internal standards can be utilized for glycomic quantitation by MS-based methods to reduce variability. In this study, we used stable isotope labeled IgG2b monoclonal antibody, iGlycoMab, as an internal standard to reduce potential for errors and to reduce variabililty due to sample digestion, derivatization, and fluctuation of nanoESI efficiency in the LC-MS analysis of permethylated N-glycans released from model glycoproteins, human blood serum, and breast cancer cell line. We observed an unanticipated degradation of isotope labeled glycans, tracked a source of such degradation, and optimized a sample preparation protocol to minimize degradation of the internal standard glycans. All results indicated the effectiveness of using iGlycoMab to minimize errors originating from sample handling and instruments. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Global standard for the composition of infant formula: recommendations of an ESPGHAN coordinated international expert group.

    PubMed

    Koletzko, Berthold; Baker, Susan; Cleghorn, Geoff; Neto, Ulysses Fagundes; Gopalan, Sarath; Hernell, Olle; Hock, Quak Seng; Jirapinyo, Pipop; Lonnerdal, Bo; Pencharz, Paul; Pzyrembel, Hildegard; Ramirez-Mayans, Jaime; Shamir, Raanan; Turck, Dominique; Yamashiro, Yuichiro; Zong-Yi, Ding

    2005-11-01

    The Codex Alimentarius Commission of the Food and Agriculture Organization of the United Nations (FAO) and the World Health Organization (WHO) develops food standards, guidelines and related texts for protecting consumer health and ensuring fair trade practices globally. The major part of the world's population lives in more than 160 countries that are members of the Codex Alimentarius. The Codex Standard on Infant Formula was adopted in 1981 based on scientific knowledge available in the 1970s and is currently being revised. As part of this process, the Codex Committee on Nutrition and Foods for Special Dietary Uses asked the ESPGHAN Committee on Nutrition to initiate a consultation process with the international scientific community to provide a proposal on nutrient levels in infant formulae, based on scientific analysis and taking into account existing scientific reports on the subject. ESPGHAN accepted the request and, in collaboration with its sister societies in the Federation of International Societies on Pediatric Gastroenterology, Hepatology and Nutrition, invited highly qualified experts in the area of infant nutrition to form an International Expert Group (IEG) to review the issues raised. The group arrived at recommendations on the compositional requirements for a global infant formula standard which are reported here.

  14. International standards for tuberculosis care.

    PubMed

    Hopewell, Philip C; Pai, Madhukar; Maher, Dermot; Uplekar, Mukund; Raviglione, Mario C

    2006-11-01

    Part of the reason for failing to bring about a more rapid reduction in tuberculosis incidence worldwide is the lack of effective involvement of all practitioners-public and private-in the provision of high quality tuberculosis care. While health-care providers who are part of national tuberculosis programmes have been trained and are expected to have adopted proper diagnosis, treatment, and public-health practices, the same is not likely to be true for non-programme providers. Studies of the performance of the private sector conducted in several different parts of the world suggest that poor quality care is common. The basic principles of care for people with, or suspected of having, tuberculosis are the same worldwide: a diagnosis should be established promptly; standardised treatment regimens should be used with appropriate treatment support and supervision; response to treatment should be monitored; and essential public-health responsibilities must be carried out. Prompt and accurate diagnosis, and effective treatment are essential for good patient care and tuberculosis control. All providers who undertake evaluation and treatment of patients with tuberculosis must recognise that not only are they delivering care to an individual, but they are also assuming an important public-health function. The International Standards for Tuberculosis Care (ISTC) describe a widely endorsed level of care that all practitioners should seek to achieve in managing individuals who have, or are suspected of having, tuberculosis. The document is intended to engage all care providers in delivering high quality care for patients of all ages, including those with smear-positive, smear-negative, and extra-pulmonary tuberculosis, tuberculosis caused by drug-resistant Mycobacterium tuberculosis complex, and tuberculosis combined with HIV infection.

  15. Virtual surgical planning and three-dimensional printing in multidisciplinary oncologic chest wall resection and reconstruction: A case report.

    PubMed

    Sharaf, Basel; Sabbagh, M Diya; Vijayasekaran, Aparna; Allen, Mark; Matsumoto, Jane

    2018-04-30

    Primary sarcomas of the sternum are extremely rare and present the surgical teams involved with unique challenges. Historically, local muscle flaps have been utilized to reconstruct the resulting defect. However, when the resulting oncologic defect is larger than anticipated, local tissues have been radiated, or when preservation of chest wall muscles is necessary to optimize function, local reconstructive options are unsuitable. Virtual surgical planning (VSP) and in house three-dimensional (3D) printing provides the platform for improved understanding of the anatomy of complex tumours, communication amongst surgeons, and meticulous pre-operative planning. We present the novel use of this technology in the multidisciplinary surgical care of a 35 year old male with primary sarcoma of the sternum. Emphasis on minimizing morbidity, maintaining function of chest wall muscles, and preservation of the internal mammary vessels for microvascular anastomosis are discussed. While the majority of patients at our institution receive local or regional flaps for reconstruction of thoracic defects, advances in microvascular surgery allow the reconstructive surgeon the latitude to choose other flap options if necessary. VSP and 3D printing allowed the surgical team involved to utilize free tissue transfer to reconstruct the defect with free tissue transfer from the thigh. Perseveration of the internal mammary vessels was paramount during tumor extirpation. Virtual surgical planning and rapid prototyping is a useful adjunct to standard imaging in complex chest wall resection and reconstruction. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  16. 75 FR 55559 - Light-Walled Rectangular Pipe and Tube From Mexico: Preliminary Results of Antidumping Duty...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-13

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-201-836] Light-Walled Rectangular... administrative review of the antidumping duty order on light-walled rectangular pipe and tube (LWRPT) from Mexico... Light-Walled Rectangular Pipe and Tube from Mexico, the People's Republic of China, and the Republic of...

  17. Analysis of thermoelastic characteristics in a thick walled FGM cylinder

    NASA Astrophysics Data System (ADS)

    Tanvir, A. N. M.; Islam, Md. Didarul; Ahmed, Faisal

    2017-12-01

    This study is concerned with the behavior of stress and strain in a thick walled functionally graded material (FGM) cylinder under internal pressure. The incompatible eigenstrain and equivalent eigenstrain developed in the cylinder, are taken into account. As a demonstration, a TiC/Al2O3 FGM cylinder is considered and different components of stress and strain are presented in order to study the effects of internal pressure, temperature difference (between room and sintering temperature), cylinder wall thickness and material distribution. The numerical result presented here shows that the thermoelastic characteristic like stress and strain of an FGM cylinder is significantly influenced by some of the above-mentioned parameters and can be controlled by properly controlling these parameters.

  18. Standard Errors for National Trends in International Large-Scale Assessments in the Case of Cross-National Differential Item Functioning

    ERIC Educational Resources Information Center

    Sachse, Karoline A.; Haag, Nicole

    2017-01-01

    Standard errors computed according to the operational practices of international large-scale assessment studies such as the Programme for International Student Assessment's (PISA) or the Trends in International Mathematics and Science Study (TIMSS) may be biased when cross-national differential item functioning (DIF) and item parameter drift are…

  19. Internal mammary lymph node inclusion in standard tangent breast fields: effects of body habitus.

    PubMed

    Proulx, G M; Lee, R J; Stomper, P C

    2001-01-01

    The purpose of this study was to determine the variability of internal mammary node (IMN) coverage with standard breast tangent fields using surface anatomy as determined by computed tomography (CT) planning for patients treated with either breast-conserving treatment or postmastectomy, and to evaluate the influence of body habitus and shape on IMN coverage with standard tangent fields. This prospective study included consecutive women with breast cancer who underwent either local excision or mastectomy and had standard tangent fields intended to cover the breast plus a margin simulated using surface anatomy. CT planning determined the location of the IMN with respect to the tangent fields designed from surface anatomy. The internal mammary vessels were used as surrogates for the IMNs. CT measurements of the presternal fat thickness and anteroposterior (AP) and transverse skeletal diameters were made to determine their relationship to the inclusion of IMNs within the tangent fields. Only seven patients (14%) had their IMNs completely within the tangent fields. Twenty patients (40%) had partial coverage of their IMNs, and 23 (46%) had their IMNs completely outside the fields. IMN inclusion was inversely correlated with presternal fat thickness. Thoracic skeletal shape was not associated with IMN inclusion. Standard tangent fields generally do not cover the IMNs completely but may cover them at least partially in a majority of patients. The presternal fat thickness is inversely correlated with IMN inclusion in the tangent fields.

  20. Hydrophilic interaction liquid chromatography of anthranilic acid-labelled oligosaccharides with a 4-aminobenzoic acid ethyl ester-labelled dextran hydrolysate internal standard.

    PubMed

    Neville, David C A; Alonzi, Dominic S; Butters, Terry D

    2012-04-13

    Hydrophilic interaction liquid chromatography (HILIC) of fluorescently labelled oligosaccharides is used in many laboratories to analyse complex oligosaccharide mixtures. Separations are routinely performed using a TSK gel-Amide 80 HPLC column, and retention times of different oligosaccharide species are converted to glucose unit (GU) values that are determined with reference to an external standard. However, if retention times were to be compared with an internal standard, consistent and more accurate GU values would be obtained. We present a method to perform internal standard-calibrated HILIC of fluorescently labelled oligosaccharides. The method relies on co-injection of 4-aminobenzoic acid ethyl ester (4-ABEE)-labelled internal standard and detection by UV absorption, with 2-AA (2-aminobenzoic acid)-labelled oligosaccharides. 4-ABEE is a UV chromophore and a fluorophore, but there is no overlap of the fluorescent spectrum of 4-ABEE with the commonly used fluorescent reagents. The dual nature of 4-ABEE allows for accurate calculation of the delay between UV and fluorescent signals when determining the GU values of individual oligosaccharides. The GU values obtained are inherently more accurate as slight differences in gradients that can influence retention are negated by use of an internal standard. Therefore, this paper provides the first method for determination of HPLC-derived GU values of fluorescently labelled oligosaccharides using an internal calibrant. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Advanced Extended Plate and Beam Wall System in a Cold-Climate House

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mallay, Dave; Wiehagen, Joseph; Kochkin, Vladimir

    This report presents the design and evaluation of an innovative wall system. This highly insulated (high-R) light-frame wall system for use above grade in residential buildings is referred to as Extended Plate & Beam (EP&B). The EP&B design is the first of its kind to be featured in a new construction test house (NCTH) for the DOE Building America program. The EP&B wall design integrates standard building methods and common building products to construct a high-R wall that minimizes transition risks and costs to builders.

  2. 30. Photographic copy of Wall Sections and Details (The Ballinger ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    30. Photographic copy of Wall Sections and Details (The Ballinger Company, April 12, 1955). In files of the City of Philadelphia, Division of Aviation, Terminal E. Philadelphia International Airport Reprinted with permission of the Division of Aviation. - TWA Maintenance Hangar, South side of Tinicum Island Road, Philadelphia International Airport, Philadelphia, Philadelphia County, PA

  3. Moisture Management of High-R Walls (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    2013-12-01

    The following report explains the moisture-related concerns for High R-value wall assemblies and discusses past Building America research work that informs this study. Hygrothermal simulations were prepared for several common approaches to High R-value wall construction in six cities (Houston, Atlanta, Seattle, St. Louis, Chicago, and International Falls) representing a range of climate zones (2, 3, 4C, 4, 5A, and 7, respectively). The simulations are informed by experience gained from past research in this area and validated by field measurement and forensic experience. The modeling program was developed to assess the moisture durability of the wall assemblies based on threemore » primary sources of moisture: construction moisture, air leakage condensation, and bulk water leakage. The peak annual moisture content of the wood based exterior sheathing was used to comparatively analyze the response to the moisture loads for each of the walls in each given city. Walls which experienced sheathing moisture contents between 20% and 28% were identified as risky, whereas those exceeding 28% were identified as very high risk. All of the wall assemblies perform well under idealized conditions. However, only the walls with exterior insulation, or cavity insulation which provides a hygrothermal function similar to exterior insulation, perform adequately when exposed to moisture loads. Walls with only cavity insulation are particularly susceptible to air leakage condensation. None of the walls performed well when a precipitation based bulk water leak was introduced to the backside of the sheathing, emphasizing the importance of proper flashing details.« less

  4. Applying the Joint Committee's 1994 Standards in International Contexts: A Case Study of Education Evaluations in Bangladesh

    ERIC Educational Resources Information Center

    Chatterji, Madhabi

    2005-01-01

    This case study examines the applicability of 1994 standards, offered by the Joint Committee on Standards for Educational Evaluation, to evaluations conducted in international contexts. The work is undertaken in response to an open invitation from the Joint Committee in its 1994 publication. The article addresses two purposes. First, it asks…

  5. Analysis of wall shear stress around a competitive swimmer using 3D Navier-Stokes equations in CFD.

    PubMed

    Popa, C V; Zaidi, H; Arfaoui, A; Polidori, G; Taiar, R; Fohanno, S

    2011-01-01

    This paper deals with the flow dynamics around a competitive swimmer during underwater glide phases occurring at the start and at every turn. The influence of the head position, namely lifted up, aligned and lowered, on the wall shear stress and the static pressure distributions is analyzed. The problem is considered as 3D and in steady hydrodynamic state. Three velocities (1.4 m/s, 2.2 m/s and 3.1 m/s) that correspond to inter-regional, national and international swimming levels are studied. The flow around the swimmer is assumed turbulent. The Reynolds-averaged Navier-Stokes (RANS) equations are solved with the standard k-ω turbulent model by using the CFD (computational fluid dynamics) numerical method based on a volume control approach. Numerical simulations are carried out with the ANSYS FLUENT® CFD code. The results show that the wall shear stress increases with the velocity and consequently the drag force opposing the movement of the swimmer increases as well. Also, high wall shear stresses are observed in the areas where the body shape, globally rigid in form, presents complex surface geometries such as the head, shoulders, buttocks, heel and chest.

  6. Effect of Yeast Cell Morphology, Cell Wall Physical Structure and Chemical Composition on Patulin Adsorption.

    PubMed

    Luo, Ying; Wang, Jianguo; Liu, Bin; Wang, Zhouli; Yuan, Yahong; Yue, Tianli

    2015-01-01

    The capability of yeast to adsorb patulin in fruit juice can aid in substantially reducing the patulin toxic effect on human health. This study aimed to investigate the capability of yeast cell morphology and cell wall internal structure and composition to adsorb patulin. To compare different yeast cell morphologies, cell wall internal structure and composition, scanning electron microscope, transmission electron microscope and ion chromatography were used. The results indicated that patulin adsorption capability of yeast was influenced by cell surface areas, volume, and cell wall thickness, as well as 1,3-β-glucan content. Among these factors, cell wall thickness and 1,3-β-glucan content serve significant functions. The investigation revealed that patulin adsorption capability was mainly affected by the three-dimensional network structure of the cell wall composed of 1,3-β-glucan. Finally, patulin adsorption in commercial kiwi fruit juice was investigated, and the results indicated that yeast cells could adsorb patulin from commercial kiwi fruit juice efficiently. This study can potentially simulate in vitro cell walls to enhance patulin adsorption capability and successfully apply to fruit juice industry.

  7. 78 FR 1199 - Light-Walled Rectangular Pipe and Tube From Mexico: Final Results of Antidumping Duty...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-08

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-201-836] Light-Walled Rectangular... order on light-walled rectangular pipe and tube (LWR pipe and tube) from Mexico. This review covers two... but received no such comments. We also did not receive a request for a hearing. \\1\\ See Light-Walled...

  8. Double standards and the international trade of pesticides: the Brazilian case.

    PubMed

    Porto, Marcelo Firpo; Milanez, Bruno; Soares, Wagner Lopes; Meyer, Armando

    2010-01-01

    Despite bans on certain pesticides and their replacement by others considered less hazardous, the widespread use of these substances in agriculture continues to threaten the environment and the health of millions of people. This article discusses the current double standard in the international trade of pesticides and focuses on Brazil, one of the main users of pesticides in the world, analyzing the trends in foreign trade (imports and exports) of selected pesticides as a function of changes in legislation in the United States, the European Union, and Brazil from 1989 to 2006. We applied time line analysis to eight organochlorines already banned in Brazil and conducted a case-by-case qualitative and quantitative analysis of nine other pesticides. The results indicate the existence of double standards, as demonstrated by the continued exports to Brazil of some pesticides banned in the United States and Europe.

  9. Validation of the international labour office digitized standard images for recognition and classification of radiographs of pneumoconiosis.

    PubMed

    Halldin, Cara N; Petsonk, Edward L; Laney, A Scott

    2014-03-01

    Chest radiographs are recommended for prevention and detection of pneumoconiosis. In 2011, the International Labour Office (ILO) released a revision of the International Classification of Radiographs of Pneumoconioses that included a digitized standard images set. The present study compared results of classifications of digital chest images performed using the new ILO 2011 digitized standard images to classification approaches used in the past. Underground coal miners (N = 172) were examined using both digital and film-screen radiography (FSR) on the same day. Seven National Institute for Occupational Safety and Health-certified B Readers independently classified all 172 digital radiographs, once using the ILO 2011 digitized standard images (DRILO2011-D) and once using digitized standard images used in the previous research (DRRES). The same seven B Readers classified all the miners' chest films using the ILO film-based standards. Agreement between classifications of FSR and digital radiography was identical, using a standard image set (either DRILO2011-D or DRRES). The overall weighted κ value was 0.58. Some specific differences in the results were seen and noted. However, intrareader variability in this study was similar to the published values and did not appear to be affected by the use of the new ILO 2011 digitized standard images. These findings validate the use of the ILO digitized standard images for classification of small pneumoconiotic opacities. When digital chest radiographs are obtained and displayed appropriately, results of pneumoconiosis classifications using the 2011 ILO digitized standards are comparable to film-based ILO classifications and to classifications using earlier research standards. Published by Elsevier Inc.

  10. Aid conditionalities, international Good Manufacturing Practice standards and local production rights: a case study of local production in Nepal.

    PubMed

    Brhlikova, Petra; Harper, Ian; Subedi, Madhusudan; Bhattarai, Samita; Rawal, Nabin; Pollock, Allyson M

    2015-06-14

    Local pharmaceutical production has been endorsed by the WHO as a means of addressing health priorities of developing countries. However, local producers of essential medicines must comply with international pharmaceutical standards in order to be eligible to compete in donor tenders. These standards determine production rights for on-patent and off-patent medicines, and guide international procurement of medicines. We reviewed the literature on the impact of Good Manufacturing Practice (GMP) on local production; a gap analysis from the literature review indicated a need for further research. Over sixty interviews were conducted with people involved in the Nepali pharmaceutical production and distribution chain from 2006 to 2009 on the GMP areas of relevance: regulatory capacity, staffing, funding and training, resourcing of GMP, inspectors' interpretation of the rules and compliance. Although Nepal producers have increased their overall share of the domestic market, only the public manufacturer, Royal Drugs, focuses on medicines for public health programmes; private producers engage mainly in brand competition for private markets, not essential medicines. Nepali regulators and producers state that implementation of GMP standards is hindered by low regulatory capacity, insufficient training of staff in the industry, financial constraints and lack of investment for upgrading capital. The transition period to mandatory compliance with WHO GMP rules is lengthy. Less than half of private producers had WHO GMP in 2013. Producers are not directly affected by international harmonisation of standards as they do not export medicines and the Nepali regulator does not enforce the WHO standards strictly. Without an international GMP certificate they cannot tender for donor dependent health programmes. In Nepal, local private manufacturers focus mainly on brand competition for private consumption not essential medicines, the government preferentially procures essential

  11. Internal standards in fluorescent X-ray spectroscopy1 1 Publication authorized by the Director, U.S. Geological Survey.

    USGS Publications Warehouse

    Adler, I.; Axelrod, J.M.

    1955-01-01

    The use of internal standards in the analysis of ores and minerals of widely-varying matrix by means of fluorescent X-ray spectroscopy is frequently the most practical approach. Internal standards correct for absorption and enhancement effects except when an absorption edge falls between the comparison lines or a very strong emission line falls between the absorption edges responsible for the comparison lines. Particle size variations may introduce substantial errors. One method of coping with the particle size problem is grinding the sample with an added abrasive. ?? 1955.

  12. A Near-Wall Reynolds-Stress Closure without Wall Normals

    NASA Technical Reports Server (NTRS)

    Yuan, S. P.; So, R. M. C.

    1997-01-01

    With the aid of near-wall asymptotic analysis and results of direct numerical simulation, a new near-wall Reynolds stress model (NNWRS) is formulated based on the SSG high-Reynolds-stress model with wall-independent near-wall corrections. Only one damping function is used for flows with a wide range of Reynolds numbers to ensure that the near-wall modifications diminish away from the walls. The model is able to reproduce complicated flow phenomena induced by complex geometry, such as flow recirculation, reattachment and boundary-layer redevelopment in backward-facing step flow and secondary flow in three-dimensional square duct flow. In simple flows, including fully developed channel/pipe flow, Couette flow and boundary-layer flow, the wall effects are dominant, and the NNWRS model predicts less degree of turbulent anisotropy in the near-wall region compared with a wall-dependent near-wall Reynolds Stress model (NWRS) developed by So and colleagues. The comparison of the predictions given by the two models rectifies the misconception that the overshooting of skin friction coefficient in backward-facing step flow prevalent in those near-wall, models with wall normal is caused by he use of wall normal.

  13. The emergence of international food safety standards and guidelines: understanding the current landscape through a historical approach.

    PubMed

    Ramsingh, Brigit

    2014-07-01

    Following the Second World War, the Food and Agriculture Organization (FAO) and the World Health Organization (WHO) teamed up to construct an International Codex Alimentarius (or 'food code') which emerged in 1963. The Codex Committee on Food Hygiene (CCFH) was charged with the task of developing microbial hygiene standards, although it found itself embroiled in debate with the WHO over the nature these standards should take. The WHO was increasingly relying upon the input of biometricians and especially the International Commission on Microbial Specifications for Foods (ICMSF) which had developed statistical sampling plans for determining the microbial counts in the final end products. The CCFH, however, was initially more focused on a qualitative approach which looked at the entire food production system and developed codes of practice as well as more descriptive end-product specifications which the WHO argued were 'not scientifically correct'. Drawing upon historical archival material (correspondence and reports) from the WHO and FAO, this article examines this debate over microbial hygiene standards and suggests that there are many lessons from history which could shed light upon current debates and efforts in international food safety management systems and approaches.

  14. A combined application of thermal desorber and gas chromatography to the analysis of gaseous carbonyls with the aid of two internal standards.

    PubMed

    Kim, Ki-Hyun; Anthwal, A; Pandey, Sudhir Kumar; Kabir, Ehsanul; Sohn, Jong Ryeul

    2010-11-01

    In this study, a series of GC calibration experiments were conducted to examine the feasibility of the thermal desorption approach for the quantification of five carbonyl compounds (acetaldehyde, propionaldehyde, butyraldehyde, isovaleraldehyde, and valeraldehyde) in conjunction with two internal standard compounds. The gaseous working standards of carbonyls were calibrated with the aid of thermal desorption as a function of standard concentration and of loading volume. The detection properties were then compared against two types of external calibration data sets derived by fixed standard volume and fixed standard concentration approach. According to this comparison, the fixed standard volume-based calibration of carbonyls should be more sensitive and reliable than its fixed standard concentration counterpart. Moreover, the use of internal standard can improve the analytical reliability of aromatics and some carbonyls to a considerable extent. Our preliminary test on real samples, however, indicates that the performance of internal calibration, when tested using samples of varying dilution ranges, can be moderately different from that derivable from standard gases. It thus suggests that the reliability of calibration approaches should be examined carefully with the considerations on the interactive relationships between the compound-specific properties and the operation conditions of the instrumental setups.

  15. Anthropometric protocols for the construction of new international fetal and newborn growth standards: the INTERGROWTH-21st Project.

    PubMed

    Cheikh Ismail, L; Knight, H E; Bhutta, Z; Chumlea, W C

    2013-09-01

    The primary aim of the INTERGROWTH-21(st) Project is to construct new, prescriptive standards describing optimal fetal and preterm postnatal growth. The anthropometric measurements include the head circumference, recumbent length and weight of the infants, and the stature and weight of the parents. In such a large, international, multicentre project, it is critical that all study sites follow standardised protocols to ensure maximal validity of the growth and nutrition indicators used. This paper describes, in detail, the selection of anthropometric personnel, equipment, and measurement and calibration protocols used to construct the new standards. Implementing these protocols at each study site ensures that the anthropometric data are of the highest quality to construct the international standards. © 2013 Royal College of Obstetricians and Gynaecologists.

  16. International Review of the Development and Implementation of Energy Efficiency Standards and Labeling Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Nan; Zheng, Nina; Fridley, David

    2012-02-28

    Appliance energy efficiency standards and labeling (S&L) programs have been important policy tools for regulating the efficiency of energy-using products for over 40 years and continue to expand in terms of geographic and product coverage. The most common S&L programs include mandatory minimum energy performance standards (MEPS) that seek to push the market for efficient products, and energy information and endorsement labels that seek to pull the market. This study seeks to review and compare some of the earliest and most well-developed S&L programs in three countries and one region: the U.S. MEPS and ENERGY STAR, Australia MEPS and Energymore » Label, European Union MEPS and Ecodesign requirements and Energy Label and Japanese Top Runner programs. For each program, key elements of S&L programs are evaluated and comparative analyses across the programs undertaken to identify best practice examples of individual elements as well as cross-cutting factors for success and lessons learned in international S&L program development and implementation. The international review and comparative analysis identified several overarching themes and highlighted some common factors behind successful program elements. First, standard-setting and programmatic implementation can benefit significantly from a legal framework that stipulates a specific timeline or schedule for standard-setting and revision, product coverage and legal sanctions for non-compliance. Second, the different MEPS programs revealed similarities in targeting efficiency gains that are technically feasible and economically justified as the principle for choosing a standard level, in many cases at a level that no product on the current market could reach. Third, detailed survey data such as the U.S. Residential Energy Consumption Survey (RECS) and rigorous analyses provide a strong foundation for standard-setting while incorporating the participation of different groups of stakeholders further strengthen the

  17. Creating an educationally minded schedule: one approach to minimize the impact of duty hour standards on intern continuity clinic experience.

    PubMed

    DeBlasio, Dominick; Kerrey, M Kathleen; Sucharew, Heidi; Klein, Melissa

    2014-11-01

    To determine if implementing an educationally minded schedule utilizing consecutive night shifts can moderate the impact of the 2011 duty hour standards on education and patient continuity of care in longitudinal primary care experience (continuity clinic). A 14-month pre-post study was performed in continuity clinic with one supervising physician group and two intern groups. Surveys to assess attitudes and education were distributed to the supervising physicians and interns before and after the changes in duty hour standards. Intern groups' schedules were reviewed for the number of regular and alternative day clinic (i.e. primary care experience on a different weekday) sessions and patient continuity of care. Fifteen supervising physicians and 51 interns participated (25 in 2011, 26 in 2012). Intern groups' comfort when discussing patient issues, educational needs and teamwork perception did not differ. Supervising physicians' understanding of learning needs and provision of feedback did not differ between groups. Supervising physicians indicated a greater ability to provide feedback and understand learning needs during regular continuity clinic sessions compared with alternative day clinics (all p < 0.05). No significant difference was detected between intern groups in the number of regularly scheduled continuity clinics, alternative day clinics or patient continuity of care. The 2011 duty hour standards required significant alterations to intern schedules, but educationally minded scheduling limited impact on education and patient continuity in care.

  18. Valid internal standard technique for arson detection based on gas chromatography-mass spectrometry.

    PubMed

    Salgueiro, Pedro A S; Borges, Carlos M F; Bettencourt da Silva, Ricardo J N

    2012-09-28

    The most popular procedures for the detection of residues of accelerants in fire debris are the ones published by the American Society for Testing and Materials (ASTM E1412-07 and E1618-10). The most critical stages of these tests are the conservation of fire debris from the sampling to the laboratory, the extraction of residues of accelerants from the debris to the activated charcoal strips (ACS) and from those to the final solvent, as well as the analysis of sample extract by gas chromatography-mass spectrometry (GC-MS) and the interpretation of the instrumental signal. This work proposes a strategy for checking the quality of the sample conservation, the accelerant residues transference to final solvent and GC-MS analysis, using internal standard additions. It is used internal standards ranging from a highly volatile compound for checking debris conservation to low volatile compound for checking GC-MS repeatability. The developed quality control (QC) parameters are not affected by GC-MS sensitivity variation and, specifically, the GC-MS performance control is not affected by ACS adsorption saturation that may mask test performance deviations. The proposed QC procedure proved to be adequate to check GC-MS repeatability, ACS extraction and sample conservation since: (1) standard additions are affected by negligible uncertainty and (2) observed dispersion of QC parameters are fit for its intended use. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. 78 FR 54864 - Light-Walled Rectangular Pipe and Tube From Mexico: Preliminary Results and Partial Rescission of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-06

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-201-836] Light-Walled Rectangular... the antidumping duty order on light-walled rectangular pipe and tube (LWR pipe and tube) from Mexico... The merchandise subject to the order is certain welded carbon- quality light-walled steel pipe and...

  20. The Impact of International Financial Reporting Standards on Accounting Curriculum in the United States

    ERIC Educational Resources Information Center

    Yallapragada, RamMohan R.; Toma, Alfred G.; Roe, C. William

    2011-01-01

    According to the time line presently specified by the Securities and Exchange Commission (SEC), business firms in the United States (US) should switch from the existing US accounting reporting guidelines of the Generally Accepted Accounting Principles (GAAP) to International Financial Reporting Standards (IFRS) by the year 2014. The US business…

  1. International Standard Classification of Education (ISCED) Three Stage Classification System: 1973; Part 2 - Definitions.

    ERIC Educational Resources Information Center

    United Nations Educational, Scientific, and Cultural Organization, Paris (France).

    The seven levels of education, as classified numerically by International Standard Classification of Education (ISCED), are defined along with courses, programs, and fields of education listed under each level. Also contained is an alphabetical subject index indicating appropriate code numbers. For related documents see TM003535 and TM003536. (RC)

  2. Application of Internal Standard Method for Several 3d-Transition Metallic Elements in Flame Atomic Absorption Spectrometry Using a Multi-wavelength High-resolution Spectrometer.

    PubMed

    Toya, Yusuke; Itagaki, Toshiko; Wagatsuma, Kazuaki

    2017-01-01

    We investigated a simultaneous internal standard method in flame atomic absorption spectrometry (FAAS), in order to better the analytical precision of 3d-transition metals contained in steel materials. For this purpose, a new spectrometer system for FAAS, comprising a bright xenon lamp as the primary radiation source and a high-resolution Echelle monochromator, was employed to measure several absorption lines at a wavelength width of ca. 0.3 nm at the same time, which enables the absorbances of an analytical line and also an internal standard line to be estimated. In considering several criteria for selecting an internal standard element and the absorption line, it could be suggested that platinum-group elements: ruthenium, rhodium, or palladium, were suitable for an internal standard element to determine the 3d-transition metal elements, such as titanium, iron, and nickel, by measuring an appropriate pair of these absorption lines simultaneously. Several variances of the absorption signal, such as a variation in aspirated amounts of sample solution and a short-period drift of the primary light source, would be corrected and thus reduced, when the absorbance ratio of the analytical line to the internal standard line was measured. In Ti-Pd, Ni-Rh, and Fe-Ru systems chosen as typical test samples, the repeatability of the signal respnses was investigated with/without the internal standard method, resulting in better precision when the internal standard method was applied in the FAAS with a nitrous oxide-acetylene flame rather than an air-acetylene flame.

  3. Commutability of the First World Health Organization International Standard for Human Cytomegalovirus

    PubMed Central

    Preiksaitis, J.; Tong, Y.; Pang, X.; Sun, Y.; Tang, L.; Cook, L.; Pounds, S.; Fryer, J.; Caliendo, A. M.

    2015-01-01

    Quantitative detection of cytomegalovirus (CMV) DNA has become a standard part of care for many groups of immunocompromised patients; recent development of the first WHO international standard for human CMV DNA has raised hopes of reducing interlaboratory variability of results. Commutability of reference material has been shown to be necessary if such material is to reduce variability among laboratories. Here we evaluated the commutability of the WHO standard using 10 different real-time quantitative CMV PCR assays run by eight different laboratories. Test panels, including aliquots of 50 patient samples (40 positive samples and 10 negative samples) and lyophilized CMV standard, were run, with each testing center using its own quantitative calibrators, reagents, and nucleic acid extraction methods. Commutability was assessed both on a pairwise basis and over the entire group of assays, using linear regression and correspondence analyses. Commutability of the WHO material differed among the tests that were evaluated, and these differences appeared to vary depending on the method of statistical analysis used and the cohort of assays included in the analysis. Depending on the methodology used, the WHO material showed poor or absent commutability with up to 50% of assays. Determination of commutability may require a multifaceted approach; the lack of commutability seen when using the WHO standard with several of the assays here suggests that further work is needed to bring us toward true consensus. PMID:26269622

  4. INTERNAL TRANSCRIBED SPACER (ITS), AN IDEAL DNA BARCODE FOR SPECIES DISCRIMINATION IN CRAWFURDIA WALL. (GENTIANACEAE).

    PubMed

    Zhang, Dequan; Jiang, Bei; Duan, Lizhen; Zhou, Nong

    2016-01-01

    DNA barcoding is a technique used to identify species based on species-specific differences in short regions of their DNA. It is widely used in species discrimination of medicinal plants and traditional medicines. In the present study, four potential DNA barcodes, namely rbcL , matK , trnH-psbA and ITS (nuclear ribosomal internal transcribed spacer) were adopted for species discrimination in Crawfurdia Wall (Genetiaceae). Identification ability of these DNA barcodes and combinations were evaluated using three classic methods (Distance, Blast and Tree-Building). As a result, ITS, trnH-psbA and rbcL regions showed great universality for a success rate of 100%; whereas matK was disappointing for which only 65% samples gained useful DNA sequences. ITS region, which could clearly and effectively identify the five species in Crawfurdia , performed very well in this study. On the contrary, trnH-psbA and rbcL performed poorly in discrimination among these species. ITS marker was an ideal DNA barcode in Crawfurdia and it should be incorporated into one of the core barcodes for seed plants.

  5. 75 FR 9647 - National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-03

    ...EPA is promulgating national emission standards for hazardous air pollutants for existing stationary compression ignition reciprocating internal combustion engines that either are located at area sources of hazardous air pollutant emissions or that have a site rating of less than or equal to 500 brake horsepower and are located at major sources of hazardous air pollutant emissions. In addition, EPA is promulgating national emission standards for hazardous air pollutants for existing non-emergency stationary compression ignition engines greater than 500 brake horsepower that are located at major sources of hazardous air pollutant emissions. Finally, EPA is revising the provisions related to startup, shutdown, and malfunction for the engines that were regulated previously by these national emission standards for hazardous air pollutants.

  6. Progress in Quantitative Viral Load Testing: Variability and Impact of the WHO Quantitative International Standards

    PubMed Central

    Sun, Y.; Tang, L.; Procop, G. W.; Hillyard, D. R.; Young, S. A.; Caliendo, A. M.

    2016-01-01

    ABSTRACT It has been hoped that the recent availability of WHO quantitative standards would improve interlaboratory agreement for viral load testing; however, insufficient data are available to evaluate whether this has been the case. Results from 554 laboratories participating in proficiency testing surveys for quantitative PCR assays of cytomegalovirus (CMV), Epstein-Barr virus (EBV), BK virus (BKV), adenovirus (ADV), and human herpesvirus 6 (HHV6) were evaluated to determine overall result variability and then were stratified by assay manufacturer. The impact of calibration to international units/ml (CMV and EBV) on variability was also determined. Viral loads showed a high degree of interlaboratory variability for all tested viruses, with interquartile ranges as high as 1.46 log10 copies/ml and the overall range for a given sample up to 5.66 log10 copies/ml. Some improvement in result variability was seen when international units were adopted. This was particularly the case for EBV viral load results. Variability in viral load results remains a challenge across all viruses tested here; introduction of international quantitative standards may help reduce variability and does so more or less markedly for certain viruses. PMID:27852673

  7. Shear-layer structures in near-wall turbulence

    NASA Technical Reports Server (NTRS)

    Johansson, A. V.; Alfredsson, P. H.; Kim, J.

    1987-01-01

    The structure of internal shear layer observed in the near-wall region of turbulent flows is investigated by analyzing flow fields obtained from numerical simulations of channel and boundary-layer flows. It is found that the shear layer is an important contributor to the turbulence production. The conditionally averaged production at the center of the structure was almost twice as large as the long-time mean value. The shear-layer structure is also found to retain its coherence over streamwise distances on the order of a thousand viscous length units, and propagates with a constant velocity of about 10.6 u sub rho throughout the near wall region.

  8. Inverting Images of the 40s: The Berlin Wall and Collective Amnesia.

    ERIC Educational Resources Information Center

    Loshitzky, Yosefa

    1995-01-01

    Examines images of World War II invoked in two live, international music concerts (one rock, one classical) celebrating the fall of the Berlin Wall. Argues that Western television's choice of imagery represented the Wall's demise as a marker of the end of the Cold War rather than a vanishing monument of Germany's conflicted struggle with Holocaust…

  9. Revision of orthovoltage chest wall treatment using Monte Carlo simulations.

    PubMed

    Zeinali-Rafsanjani, B; Faghihi, R; Mosleh-Shirazi, M A; Mosalaei, A; Hadad, K

    2017-01-01

    Given the high local control rates observed in breast cancer patients undergoing chest wall irradiation by kilovoltage x-rays, we aimed to revisit this treatment modality by accurate calculation of dose distributions using Monte Carlo simulation. The machine components were simulated using the MCNPX code. This model was used to assess the dose distribution of chest wall kilovoltage treatment in different chest wall thicknesses and larger contour or fat patients in standard and mid sternum treatment plans. Assessments were performed at 50 and 100 cm focus surface distance (FSD) and different irradiation angles. In order to evaluate different plans, indices like homogeneity index, conformity index, the average dose of heart, lung, left anterior descending artery (LAD) and percentage target coverage (PTC) were used. Finally, the results were compared with the indices provided by electron therapy which is a more routine treatment of chest wall. These indices in a medium chest wall thickness in standard treatment plan at 50 cm FSD and 15 degrees tube angle was as follows: homogeneity index 2.57, conformity index 7.31, average target dose 27.43 Gy, average dose of heart, lung and LAD, 1.03, 2.08 and 1.60 Gy respectively and PTC 11.19%. Assessments revealed that dose homogeneity in planning target volume (PTV) and conformity between the high dose region and PTV was poor. To improve the treatment indices, the reference point was transferred from the chest wall skin surface to the center of PTV. The indices changed as follows: conformity index 7.31, average target dose 60.19 Gy, the average dose of heart, lung and LAD, 3.57, 6.38 and 5.05 Gy respectively and PTC 55.24%. Coverage index of electron therapy was 89% while it was 22.74% in the old orthovoltage method and also the average dose of the target was about 50 Gy but in the given method it was almost 30 Gy. The results of the treatment study show that the optimized standard and mid sternum treatment for different chest

  10. [The International Standards for Tuberculosis Care (ISTC): what is the importance for Japan?].

    PubMed

    Fujiwara, Paula I

    2008-07-01

    In 2005, the World Health Assembly resolved that all Member States should ensure that all persons with tuberculosis (TB) "have access to the universal standard of care based on proper diagnosis, treatment and reporting consistent with the DOTS strategy..." The purpose of the International Standards for Tuberculosis Care (ISTC) is to define the widely accepted level of care of persons either suspected of, or diagnosed with, TB by all health practitioners, especially those in the private sector, who often lack guidance and systematic evaluation of outcomes provided by government programs. Since their publication in 2006 on World TB Day, the standards have been endorsed by the major international health organizations as well as many country-level professional societies. The intention is to complement local and national control polices consistent with those of the World Health Organization: they are not intended to replace local guidelines, but are written to accommodate local differences in practice. The ISTC comprise seventeen evidence-based standards on tuberculosis diagnosis and treatment, as well as the responsibility of the public health sector. These are based on the basic principles of TB care: prompt and accurate diagnosis, standardized treatment regimens of proven efficacy, appropriate treatment support and supervision, monitoring of response to treatment and the carrying out of essential public health responsibilities. The relevance of the ISTC to the Japanese context is highlighted, in terms of when persons should be suspected of TB; the appropriate diagnostic modalities, including the use of chest radiographs; the advantages of fixed dose combinations; the importance of follow-up laboratory tests to document response to treatment, the importance of recordkeeping and reporting to public health authorities, the value of HIV testing of TB patients and the use of anti-retrovirals for those dually infected; and the assessment of drug resistance and the

  11. Commutability of Cytomegalovirus WHO International Standard in Different Matrices

    PubMed Central

    Jones, Sara; Webb, Erika M.; Barry, Catherine P.; Choi, Won S.; Abravaya, Klara B.; Schneider, George J.

    2016-01-01

    Commutability of quantitative standards allows patient results to be compared across molecular diagnostic methods and laboratories. This is critical to establishing quantitative thresholds for use in clinical decision-making. A matrix effect associated with the 1st cytomegalovirus (CMV) WHO international standard (IS) was identified using the Abbott RealTime CMV assay. A commutability study was performed to compare the CMV WHO IS and patient specimens diluted in plasma and whole blood. Patient specimens showed similar CMV DNA quantitation values regardless of the diluent or extraction procedure used. The CMV WHO IS, on the other hand, exhibited a matrix effect. The CMV concentration reported for the WHO IS diluted in plasma was within the 95% prediction interval established with patient samples. In contrast, the reported DNA concentration of the CMV WHO IS diluted in whole blood was reduced approximately 0.4 log copies/ml, and values fell outside the 95% prediction interval. Calibrating the assay by using the CMV WHO IS diluted in whole blood would introduce a bias for CMV whole-blood quantitation; samples would be reported as having higher measured concentrations, by approximately 0.4 log IU/ml. Based on the commutability study with patient samples, the RealTime CMV assay was standardized based on the CMV WHO IS diluted in plasma. A revision of the instructions for use of the CMV WHO IS should be considered to alert users of the potential impact from the diluent matrix. The identification of a matrix effect with the CMV WHO IS underscores the importance of assessing commutability of the IS in order to achieve consistent results across methods. PMID:27030491

  12. Standardization of uveitis nomenclature for reporting clinical data. Results of the First International Workshop.

    PubMed

    Jabs, Douglas A; Nussenblatt, Robert B; Rosenbaum, James T

    2005-09-01

    To begin a process of standardizing the methods for reporting clinical data in the field of uveitis. Consensus workshop. Members of an international working group were surveyed about diagnostic terminology, inflammation grading schema, and outcome measures, and the results used to develop a series of proposals to better standardize the use of these entities. Small groups employed nominal group techniques to achieve consensus on several of these issues. The group affirmed that an anatomic classification of uveitis should be used as a framework for subsequent work on diagnostic criteria for specific uveitic syndromes, and that the classification of uveitis entities should be on the basis of the location of the inflammation and not on the presence of structural complications. Issues regarding the use of the terms "intermediate uveitis," "pars planitis," "panuveitis," and descriptors of the onset and course of the uveitis were addressed. The following were adopted: standardized grading schema for anterior chamber cells, anterior chamber flare, and for vitreous haze; standardized methods of recording structural complications of uveitis; standardized definitions of outcomes, including "inactive" inflammation, "improvement'; and "worsening" of the inflammation, and "corticosteroid sparing," and standardized guidelines for reporting visual acuity outcomes. A process of standardizing the approach to reporting clinical data in uveitis research has begun, and several terms have been standardized.

  13. Inside-the-wall detection of objects with low metal content using the GPR sensor: effects of different wall structures on the detection performance

    NASA Astrophysics Data System (ADS)

    Dogan, Mesut; Yesilyurt, Omer; Turhan-Sayan, Gonul

    2018-04-01

    Ground penetrating radar (GPR) is an ultra-wideband electromagnetic sensor used not only for subsurface sensing but also for the detection of objects which may be hidden behind a wall or inserted within the wall. Such applications of the GPR technology are used in both military and civilian operations such as mine or IED (improvised explosive device) detection, rescue missions after earthquakes and investigation of archeological sites. Detection of concealed objects with low metal content is known to be a challenging problem in general. Use of A-scan, B-scan and C-scan GPR data in combination provides valuable information for target recognition in such applications. In this paper, we study the problem of target detection for potentially explosive objects embedded inside a wall. GPR data is numerically simulated by using an FDTD-based numerical computation tool when dielectric targets and targets with low metal content are inserted into different types of walls. A small size plastic bottle filled with trinitrotoluene (TNT) is used as the target with and without a metal fuse in it. The targets are buried into two different types of wall; a homogeneous brick wall and an inhomogeneous wall constructed by bricks having periodically located air holes in it. Effects of using an inhomogeneous wall structure with internal boundaries are investigated as a challenging scenario, paying special attention to preprocessing.

  14. Fenestral pore size in the internal elastic lamina affects transmural flow distribution in the artery wall.

    PubMed

    Tada, S; Tarbell, J M

    2001-06-01

    Interstitial flow through the subendothelial intima and media of an artery wall was simulated numerically to investigate the water flow distribution through fenestral pores which affects the wall shear stress on smooth muscle cells right beneath the internal elastic lamina (IEL). A two-dimensional analysis using the Brinkman model of porous media flow was performed. It was observed that the hydraulic permeability of the intimal layer should be much greater than that of the media in order to predict a reasonable magnitude for the pressure drop across the subendothelial intima and IEL (about 23 mostly at a 70 mm Hg luminal pressure). When Ki was set equal to the value in the media, this pressure drop was unrealistically high. Furthermore, the higher value of Ki produced a nearly uniform distribution of water flow through a simple array of fenestral pores all having the same diameters (1.2 microm), whereas when Ki was set at the value in the media, the flow distribution through fenestral pores was highly nonuniform and nonphysiologic. A deformable intima model predicted a nonuniform flow distribution at high pressure (180 mm Hg). Damage to the IEL was simulated by introducing a large fenestral pore (up to 17.8 microm) into the array. A dramatic increase in flow through the large pore was observed implying an altered fluid mechanical environment on the smooth muscle cells near the large pore which has implications for intimal hyperplasia and atherosclerosis. The model also predicted that the fluid shear stress on the bottom surface of an endothelial cell is on the order of 10 dyne/cm2, a level which can affect cell function.

  15. Administering Safety: Challenge Courses and Climbing Walls.

    ERIC Educational Resources Information Center

    Evans, Will

    1996-01-01

    A camp that is establishing a challenge course or climbing wall must ensure program safety. Discusses financial planning, selecting a contractor, adhering to standards for construction, inspections, staff training, screening of participants, and the administrative challenge of implementing and documenting proper actions. Sidebar discusses a study…

  16. The connection of cytoskeletal network with plasma membrane and the cell wall

    PubMed Central

    Liu, Zengyu; Persson, Staffan; Zhang, Yi

    2015-01-01

    The cell wall provides external support of the plant cells, while the cytoskeletons including the microtubules and the actin filaments constitute an internal framework. The cytoskeletons contribute to the cell wall biosynthesis by spatially and temporarily regulating the transportation and deposition of cell wall components. This tight control is achieved by the dynamic behavior of the cytoskeletons, but also through the tethering of these structures to the plasma membrane. This tethering may also extend beyond the plasma membrane and impact on the cell wall, possibly in the form of a feedback loop. In this review, we discuss the linking components between the cytoskeletons and the plasma membrane, and/or the cell wall. We also discuss the prospective roles of these components in cell wall biosynthesis and modifications, and aim to provide a platform for further studies in this field. PMID:25693826

  17. World Health Organization-World Federation of Societies of Anaesthesiologists (WHO-WFSA) International Standards for a Safe Practice of Anesthesia.

    PubMed

    Gelb, Adrian W; Morriss, Wayne W; Johnson, Walter; Merry, Alan F; Abayadeera, Anuja; Belîi, Natalia; Brull, Sorin J; Chibana, Aline; Evans, Faye; Goddia, Cyril; Haylock-Loor, Carolina; Khan, Fauzia; Leal, Sandra; Lin, Nan; Merchant, Richard; Newton, Mark W; Rowles, Jackie S; Sanusi, Arinola; Wilson, Iain; Velazquez Berumen, Adriana

    2018-06-01

    The International Standards for a Safe Practice of Anesthesia were developed on behalf of the World Federation of Societies of Anaesthesiologists (WFSA), a nonprofit organization representing anesthesiologists in 150 countries, and the World Health Organization (WHO). The recommendations have been approved by WHO and the membership of WFSA. These Standards are applicable to all anesthesia providers throughout the world. They are intended to provide guidance and assistance to anesthesia providers, their professional organizations, hospital and facility administrators, and governments for maintaining and improving the quality and safety of anesthesia care. The Standards cover professional aspects; facilities and equipment; medications and intravenous fluids; monitoring; and the conduct of anesthesia. HIGHLY RECOMMENDED standards, the functional equivalent of mandatory standards, include (amongst other things): the continuous presence of a trained and vigilant anesthesia provider; continuous monitoring of tissue oxygenation and perfusion by clinical observation and a pulse oximeter; intermittent monitoring of blood pressure; confirmation of correct placement of an endotracheal tube (if used) by auscultation and carbon dioxide detection; the use of the WHO Safe Surgery Checklist; and a system for transfer of care at the end of an anesthetic. The International Standards represent minimum standards and the goal should always be to practice to the highest possible standards, preferably exceeding the standards outlined in this document.

  18. World Health Organization-World Federation of Societies of Anaesthesiologists (WHO-WFSA) International Standards for a Safe Practice of Anesthesia.

    PubMed

    Gelb, Adrian W; Morriss, Wayne W; Johnson, Walter; Merry, Alan F

    2018-05-07

    The International Standards for a Safe Practice of Anesthesia were developed on behalf of the World Federation of Societies of Anaesthesiologists (WFSA), a non-profit organization representing anesthesiologists in 150 countries, and the World Health Organization (WHO). The recommendations have been approved by WHO and the membership of WFSA. These Standards are applicable to all anesthesia providers throughout the world. They are intended to provide guidance and assistance to anesthesia providers, their professional organizations, hospital and facility administrators, and governments for maintaining and improving the quality and safety of anesthesia care. The Standards cover professional aspects; facilities and equipment; medications and intravenous fluids; monitoring; and the conduct of anesthesia. HIGHLY RECOMMENDED standards, the functional equivalent of mandatory standards, include (amongst other things): the continuous presence of a trained and vigilant anesthesia provider; continuous monitoring of tissue oxygenation and perfusion by clinical observation and a pulse oximeter; intermittent monitoring of blood pressure; confirmation of correct placement of an endotracheal tube (if used) by auscultation and carbon dioxide detection; the use of the WHO Safe Surgery Checklist; and a system for transfer of care at the end of an anesthetic. The International Standards represent minimum standards and the goal should always be to practice to the highest possible standards, preferably exceeding the standards outlined in this document.

  19. Droplet-Wall/Film Impact in IC Engine Applications

    DTIC Science & Technology

    2017-08-14

    Report: Droplet-Wall/Film Impact in IC Engine Applications (ARO Topic 1.4.1 under ARO’s Dr. Ralph A. Anthenien) The views, opinions and/or findings...in IC Engine Applications (ARO Topic 1.4.1 under ARO’s Dr. Ralph A. Anthenien) Report Term: 0-Other Email: cklaw@princeton.edu Distribution Statement...associated with spraying in internal combustion engines (ICEs). Fuels sprayed inside engines can impact with the internal surfaces and thus not only

  20. An International Standard Set of Patient-Centered Outcome Measures After Stroke.

    PubMed

    Salinas, Joel; Sprinkhuizen, Sara M; Ackerson, Teri; Bernhardt, Julie; Davie, Charlie; George, Mary G; Gething, Stephanie; Kelly, Adam G; Lindsay, Patrice; Liu, Liping; Martins, Sheila C O; Morgan, Louise; Norrving, Bo; Ribbers, Gerard M; Silver, Frank L; Smith, Eric E; Williams, Linda S; Schwamm, Lee H

    2016-01-01

    Value-based health care aims to bring together patients and health systems to maximize the ratio of quality over cost. To enable assessment of healthcare value in stroke management, an international standard set of patient-centered stroke outcome measures was defined for use in a variety of healthcare settings. A modified Delphi process was implemented with an international expert panel representing patients, advocates, and clinical specialists in stroke outcomes, stroke registers, global health, epidemiology, and rehabilitation to reach consensus on the preferred outcome measures, included populations, and baseline risk adjustment variables. Patients presenting to a hospital with ischemic stroke or intracerebral hemorrhage were selected as the target population for these recommendations, with the inclusion of transient ischemic attacks optional. Outcome categories recommended for assessment were survival and disease control, acute complications, and patient-reported outcomes. Patient-reported outcomes proposed for assessment at 90 days were pain, mood, feeding, selfcare, mobility, communication, cognitive functioning, social participation, ability to return to usual activities, and health-related quality of life, with mobility, feeding, selfcare, and communication also collected at discharge. One instrument was able to collect most patient-reported subdomains (9/16, 56%). Minimum data collection for risk adjustment included patient demographics, premorbid functioning, stroke type and severity, vascular and systemic risk factors, and specific treatment/care-related factors. A consensus stroke measure Standard Set was developed as a simple, pragmatic method to increase the value of stroke care. The set should be validated in practice when used for monitoring and comparisons across different care settings. © 2015 The Authors.

  1. 40 CFR 60.4233 - What emission standards must I meet if I am an owner or operator of a stationary SI internal...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... I am an owner or operator of a stationary SI internal combustion engine? 60.4233 Section 60.4233... Combustion Engines Emission Standards for Owners and Operators § 60.4233 What emission standards must I meet if I am an owner or operator of a stationary SI internal combustion engine? (a) Owners and operators...

  2. 40 CFR 60.4233 - What emission standards must I meet if I am an owner or operator of a stationary SI internal...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... I am an owner or operator of a stationary SI internal combustion engine? 60.4233 Section 60.4233... Combustion Engines Emission Standards for Owners and Operators § 60.4233 What emission standards must I meet if I am an owner or operator of a stationary SI internal combustion engine? (a) Owners and operators...

  3. 40 CFR 60.4233 - What emission standards must I meet if I am an owner or operator of a stationary SI internal...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... I am an owner or operator of a stationary SI internal combustion engine? 60.4233 Section 60.4233... Combustion Engines Emission Standards for Owners and Operators § 60.4233 What emission standards must I meet if I am an owner or operator of a stationary SI internal combustion engine? (a) Owners and operators...

  4. 40 CFR 60.4233 - What emission standards must I meet if I am an owner or operator of a stationary SI internal...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... I am an owner or operator of a stationary SI internal combustion engine? 60.4233 Section 60.4233... Combustion Engines Emission Standards for Owners and Operators § 60.4233 What emission standards must I meet if I am an owner or operator of a stationary SI internal combustion engine? (a) Owners and operators...

  5. 40 CFR 60.4233 - What emission standards must I meet if I am an owner or operator of a stationary SI internal...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... I am an owner or operator of a stationary SI internal combustion engine? 60.4233 Section 60.4233... Combustion Engines Emission Standards for Owners and Operators § 60.4233 What emission standards must I meet if I am an owner or operator of a stationary SI internal combustion engine? (a) Owners and operators...

  6. Effect of Yeast Cell Morphology, Cell Wall Physical Structure and Chemical Composition on Patulin Adsorption

    PubMed Central

    Luo, Ying; Wang, Jianguo; Liu, Bin; Wang, Zhouli; Yuan, Yahong; Yue, Tianli

    2015-01-01

    The capability of yeast to adsorb patulin in fruit juice can aid in substantially reducing the patulin toxic effect on human health. This study aimed to investigate the capability of yeast cell morphology and cell wall internal structure and composition to adsorb patulin. To compare different yeast cell morphologies, cell wall internal structure and composition, scanning electron microscope, transmission electron microscope and ion chromatography were used. The results indicated that patulin adsorption capability of yeast was influenced by cell surface areas, volume, and cell wall thickness, as well as 1,3-β-glucan content. Among these factors, cell wall thickness and 1,3-β-glucan content serve significant functions. The investigation revealed that patulin adsorption capability was mainly affected by the three-dimensional network structure of the cell wall composed of 1,3-β-glucan. Finally, patulin adsorption in commercial kiwi fruit juice was investigated, and the results indicated that yeast cells could adsorb patulin from commercial kiwi fruit juice efficiently. This study can potentially simulate in vitro cell walls to enhance patulin adsorption capability and successfully apply to fruit juice industry. PMID:26295574

  7. Tissue heterogeneity in the anterior chest wall and its influence on radiation therapy of the internal mammary lymph nodes.

    PubMed

    Lindskoug, B; Hultborn, A

    1976-04-01

    The density (g cm-3) and electron density (cm-3) of material from the anterior chest wall was determined. On the average, the difference in density between rib bone and intercostal soft tissue amounted to 17 per cent, while the difference in electron density was 7 per cent. The attenuation of high-energy electrons in specimens of rib bone, costal cartilage and sternum was determined by an experimental technique, using dosimeters of TLD material. The results of determinations of attenuation of 10 and 13 MeV electrons in fresh specimens are presented. It is concluded that electron radiation in the energy range of 10 to 13 MeV can be utilized for irradiation of lymph glands along the internal thoracic vessels without risk of underdosage.

  8. Integrating the Wall Street Journal into AIS Courses

    ERIC Educational Resources Information Center

    Kohlmeyer, James M., III

    2008-01-01

    While it is important for accounting information systems (AIS) students to understand computer technology, internal controls and business processes, such knowledge is of little use without reference to appropriate contexts. Integrating Wall Street Journal (WSJ) readings and discussions into AIS classes can enrich learning by stimulating…

  9. In vitro experiments of vessel wall apposition between the Enterprise and Enterprise 2 stents for treatment of cerebral aneurysms.

    PubMed

    Kono, Kenichi; Terada, Tomoaki

    2016-02-01

    A closed-cell stent called Enterprise has been used for stent-assisted coil embolization of cerebral aneurysms. The Enterprise stent tends to cause kinks and vessel wall malposition in curved vessels and may cause thromboembolic complications. We evaluated vessel wall apposition of a new closed-cell stent, Enterprise 2, compared with a previous Enterprise stent, using curved vascular silicone models. The Enterprise or Enterprise 2 stent was deployed in curved vascular models with various radii of approximately 5 to 10 mm. Stent deployment was performed 25 times in each stent. A push-pull technique was used to minimize incomplete wall apposition. To evaluate conformity of stents, gaps between a stent and a vessel wall were measured. The gap ratio (gap / a wall diameter) was 15 % ± 17 % (mean ± standard deviation) and 41 % ± 15 % with the Enterprise 2 stent and the Enterprise stent, respectively. Taking gap ratios and radii of vessel curvature into consideration, the Enterprise 2 stent had significantly better wall apposition than the Enterprise stent (p = 0.005). In the same radius of vessel curvature, the Enterprise 2 stent had approximately half of the gap compared with the Enterprise stent. There were no significant differences in vessel straightening effects between the two stents. The Enterprise 2 stent has better wall apposition in curved vessels than the Enterprise stent. The gap between a vessel wall and the Enterprise 2 stent is approximately half that of the Enterprise stent. However, gaps and kinks are still present in curved vessels with a small radius. Caution should be taken for kinks and malposition in acutely curved vessels, such as the siphon of the internal carotid artery.

  10. Literature Review of Shear Performance of Light-weight Steel Framing Wall Panels

    NASA Astrophysics Data System (ADS)

    Zhang, Zhuangnan; Liu, Shen; Liu, Hong

    2018-03-01

    In this paper, a comprehensive review of light-weight steel framing wall panels was carried out. The structure and force characteristics of light-weight steel framing wall panels were introduced. The testing and theoretical research results on the shear behaviour of light-weight steel framing wall panels were summarized in the domestic and foreign. And combined with the existing standards in China, the author's views and ideas are put forward to the problems in the research field of this kind of structural system.

  11. [Use and versatility of titanium for the reconstruction of the thoracic wall].

    PubMed

    Córcoles Padilla, Juan Manuel; Bolufer Nadal, Sergio; Kurowski, Krzysztof; Gálvez Muñoz, Carlos; Rodriguez Paniagua, José Manuel

    2014-02-01

    Chest wall deformities/defects and chest wall resections, as well as complex rib fractures require reconstruction with various prosthetic materials to ensure the basic functions of the chest wall. Titanium provides many features that make it an ideal material for this surgery. The aim is to present our initial results with this material in several diseases. From 2008 to 2012, 14 patients were operated on and titanium was used for reconstruction of the chest wall. A total of 7 patients had chest wall tumors, 2 with sternal resection, 4 patients with chest wall deformities/defects and 3 patients with severe rib injury due to traffic accident. The reconstruction was successful in all cases, with early extubation without detecting problems in the functionality of the chest wall at a respiratory level. Patients with chest wall tumors including sternal resections were extubated in the operating room as well as the chest wall deformities. Chest trauma cases were extubated within 24h from internal rib fixation. There were no complications related to the material used and the method of implementation. Titanium is an ideal material for reconstruction of the chest wall in several clinical situations allowing for great versatility and adaptability in different chest wall reconstructions. Copyright © 2013 AEC. Published by Elsevier Espana. All rights reserved.

  12. Standard operating procedures for female orgasmic disorder: consensus of the International Society for Sexual Medicine.

    PubMed

    Laan, Ellen; Rellini, Alessandra H; Barnes, Tricia

    2013-01-01

    As the field of sexual medicine evolves, it is important to continually improve patient care by developing contemporary "standard operating procedures" (SOPs), reflecting the consensus view of experts in sexual medicine. Few, if any, consensus SOPs have been developed for the diagnosis and treatment of Female Orgasmic Disorder (FOD). The objective is to provide standard operating procedures for FOD. The SOP Committee was composed of a chair, selected by the International Society for the Study of Sexual Medicine, and two additional experts. To inform its key recommendations, the Committee used systematic reviews of available evidence and discussions during a group meeting, conference calls and e-mail communications. The Committee received no corporate funding or remuneration. A total of 12 recommendations for the assessment and treatment of FOD were generated, including suggestions for further research. Evidence-based, practice recommendations for the treatment of FOD are provided that will hopefully inform clinical decision making for those treating this common condition. © 2012 International Society for Sexual Medicine.

  13. Control of Mechanical Stresses of High Pressure Container Walls by Magnetoelastic Method

    NASA Astrophysics Data System (ADS)

    Kulak, S. M.; Novikov, V. F.; Baranov, A. V.

    2016-10-01

    Deformations of the walls of pressure vessels arising in the process of testing and operation, as well as reduce their thickness due to corrosion, to create the prerequisites for the growth of mechanical stresses which accelerating the processes of strain aging, embrittlement of the material and reducing its fatigue properties. This article is devoted to researches of the magnetoelastic demagnetization in the wall of steel vessel of loading by internal pressure. It is established that the increasing pressure on the vessel wall is accompanied by a monotonic decrease in the intensity of the magnetic stray field of local magnetization of steel. It is shown that a magnetic stray field of local magnetization of the wall of steel vessel is non-uniform due to differences in structure and stresses. It is proposed to use the obtained results to control the stress state of vessels, experiencing multi-axial loads generated by internal pressure (pipelines, oil tanks, etc.) The method of magnetoelastic of the demagnetization of the steel has a high sensitivity to mechanical stress, the simplicity of implementation and expressiveness compared to the strain gauge and method of coercive force.

  14. Standards 101; the ASA standards program

    NASA Astrophysics Data System (ADS)

    Schomer, Paul D.

    2002-11-01

    ASA supports the development of standards by serving as the secretariat for standards committees of the American National Standards Institute (ANSI). The program is organized through four ANSI technical committees (S1, S2, S3, and S12) and one administrative committee (ASACOS). S1 deals with physical acoustics, S2 deals with shock and vibration, S3 deals with physiological and psychological acoustics, and S12 deals with noise. ASACOS is the ASA Committee on Standards. The program has three primary tasks: (1) the development of National Standards (ANSI Standards), (2) the national adoption of an international standard (ANSI NAIS Standards), (3) providing the USA input to the development of International Standards (ISO and IEC Standards). At every level the main work is accomplished in Working Groups (WG) that are ''staffed'' by hundreds of volunteers--mainly ASA members from its various technical committees such as Noise, Physical Acoustics, Architectural Acoustics, Psychological and Physiological Acoustics, etc. Overall, the Standards Program involves more ASA members than does any other single function of the Society except meetings and it is the biggest outreach function of ASA affecting the health, welfare, and economic well-being of large segments of the population, the business and industrial community, and government at all levels.

  15. Standards 101: The ASA Standards program

    NASA Astrophysics Data System (ADS)

    Schomer, Paul

    2004-05-01

    ASA serves as a standards developer under the auspices of the American National Standards Institute (ANSI). The Standards Program is organized through four technical committees (S1, S2, S3, and S12) and one administrative committee (ASACOS). S1 deals with physical acoustics, S2 deals with shock and vibration, S3 deals with physiological and psychological acoustics and S12 deals with noise. ASACOS is the ASA Committee on Standards. The program has three primary tasks: (1) development of national standards (ANSI Standards), (2) national adoption of international standards (ANSI NAIS Standards), (3) providing the USA input to the development of international standards (ISO and IEC Standards). At every level the main work is accomplished in Working Groups (WG) that are staffed by hundreds of volunteers, mainly ASA members from its various technical committees such as Noise, Physical Acoustics, Architectural Acoustics, Physiological and Psychological Acoustics, etc. Overall, the Standards Program involves more ASA members than does any other single function of the society except meetings. It is the biggest outreach function of ASA affecting the health, welfare, and economic well-being of large sectors of society. It is a main way the ASA diffuses the knowledge of acoustics and its practical application, perhaps the main way.

  16. Simple method for forming thin-wall pressure vessels

    NASA Technical Reports Server (NTRS)

    Erickson, A. L.; Guist, L. R.

    1972-01-01

    Application of internal hydrostatic pressure to seam-welded circular cylindrical tanks having corner-welded, flat, circular ends forms large thin-walled high quality tanks. Form limits expansion of cylindrical portion of final tank while hemispherical ends develop freely; no external form or restraint is required to fabricate spherical tanks.

  17. Local and integral disruption forces on the tokamak wall

    NASA Astrophysics Data System (ADS)

    Pustovitov, V. D.; Kiramov, D. I.

    2018-04-01

    The disruption-induced forces on the tokamak wall are evaluated analytically within the standard large-aspect-ratio model that implies axisymmetry, circular plasma and wall, and absence of halo currents. Additionally, the ideal-wall reaction is assumed. The disruptions are modelled as rapid changes in the plasma pressure (thermal quench (TQ)) and net current (current quench (CQ)). The force distribution over the poloidal angle is found as a function of these inputs. The derived formulas allow comparison of the TQ- and CQ-produced forces calculated differently, with and without account of the poloidal current induced in the wall. The latter variant represents the inherent property of the codes treating the wall as a set of toroidal filaments. It is proved here that such a simplification leads to unacceptably large errors in the simulated forces for both TQs and CQs. It is also shown that the TQ part of the force must prevail over that due to CQ in the high-β scenarios developed for JT-60SA and ITER.

  18. The use of performance standards by AAALAC International to evaluate ethical review in European institutions.

    PubMed

    Guillen, Javier

    2010-02-01

    During the past several decades, society has become increasingly concerned about the welfare of animals used in research. Today, the public asks scientists to justify the use of research animals and to be accountable for their welfare. Research institutions, government bodies and other regulatory authorities have developed mechanisms to ensure that researchers follow the principles of the 3Rs and use and care for research animals in an ethical manner. Additionally, organizations such as the Association for Assessment and Accreditation of Laboratory Animal Care International (AAALAC International) have developed voluntary programs that can help researchers to ensure that they are caring for research animals appropriately. The author discusses how AAALAC International uses performance standards to evaluate the ethical review processes of European institutions.

  19. Construction of Extended 3D Field of Views of the Internal Bladder Wall Surface: A Proof of Concept

    NASA Astrophysics Data System (ADS)

    Ben-Hamadou, Achraf; Daul, Christian; Soussen, Charles

    2016-09-01

    3D extended field of views (FOVs) of the internal bladder wall facilitate lesion diagnosis, patient follow-up and treatment traceability. In this paper, we propose a 3D image mosaicing algorithm guided by 2D cystoscopic video-image registration for obtaining textured FOV mosaics. In this feasibility study, the registration makes use of data from a 3D cystoscope prototype providing, in addition to each small FOV image, some 3D points located on the surface. This proof of concept shows that textured surfaces can be constructed with minimally modified cystoscopes. The potential of the method is demonstrated on numerical and real phantoms reproducing various surface shapes. Pig and human bladder textures are superimposed on phantoms with known shape and dimensions. These data allow for quantitative assessment of the 3D mosaicing algorithm based on the registration of images simulating bladder textures.

  20. International comparison of AC-DC current transfer standards

    NASA Astrophysics Data System (ADS)

    Heine, G.; Garcocz, M.; Waldmann, W.

    2017-01-01

    The measurements of the international comparison of ac-dc current transfer standards identified as EURAMET.EM-K12 started in June 2012 and were completed in December 2014. Twenty NMIs in the EURAMET region and one NMI in the AFRIMET region took part: BEV (Austria), CMI (Czech Republic), PTB (Germany), METAS (Switzerland), JV (Norway), UME (Turkey), GUM (Poland), IPQ (Portugal), CEM (Spain), INRIM (Italy), SP (Sweden), DANIAmet-MI-Trescal (Denmark), BIM (Bulgaria), MKEH (Hungary), SIQ (Slovenia), LNE (France), NSAI NML (Ireland), VSL (The Netherlands), NPL (United Kingdom), Metrosert (Estonia), NIS (Egypt). The comparison was proposed to link the National Metrology Institutes organised in EURAMET to the key comparison CCEM-K12. The ac-dc current transfer difference of each travelling standard had been measured at its nominal current 10 mA and 5 A at the following frequencies: 10 Hz, 55 Hz, 1 kHz, 10 kHz, 20 kHz, 50 kHz, 100 kHz. The test points were selected to link the results with the equivalent CCEM Key Comparison (CCEM-K12), through five NMIs participating in both EURAMET and CCEM key comparisons (PTB, JV, NPL, SP and BEV). The report shows the degree of equivalence in the EURAMET region and also the degree of equivalence with the corresponding CCEM reference value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Hilfiker retaining walls with full height cast-in-place panels

    DOT National Transportation Integrated Search

    1998-02-01

    Construction of retaining walls utilizing full height panels introduces a degree of indeterminacy to the structure. The ability to effectively analyze the internal behavior of such systems, and limited field performance, qualifies them as appropriate...

  2. A One-Dimensional Global-Scaling Erosive Burning Model Informed by Blowing Wall Turbulence

    NASA Technical Reports Server (NTRS)

    Kibbey, Timothy P.

    2014-01-01

    A derivation of turbulent flow parameters, combined with data from erosive burning test motors and blowing wall tests results in erosive burning model candidates useful in one-dimensional internal ballistics analysis capable of scaling across wide ranges of motor size. The real-time burn rate data comes from three test campaigns of subscale segmented solid rocket motors tested at two facilities. The flow theory admits the important effect of the blowing wall on the turbulent friction coefficient by using blowing wall data to determine the blowing wall friction coefficient. The erosive burning behavior of full-scale motors is now predicted more closely than with other recent models.

  3. 18O-labeled proteome reference as global internal standards for targeted quantification by selected reaction monitoring-mass spectrometry.

    PubMed

    Kim, Jong-Seo; Fillmore, Thomas L; Liu, Tao; Robinson, Errol; Hossain, Mahmud; Champion, Boyd L; Moore, Ronald J; Camp, David G; Smith, Richard D; Qian, Wei-Jun

    2011-12-01

    Selected reaction monitoring (SRM)-MS is an emerging technology for high throughput targeted protein quantification and verification in biomarker discovery studies; however, the cost associated with the application of stable isotope-labeled synthetic peptides as internal standards can be prohibitive for screening a large number of candidate proteins as often required in the preverification phase of discovery studies. Herein we present a proof of concept study using an (18)O-labeled proteome reference as global internal standards (GIS) for SRM-based relative quantification. The (18)O-labeled proteome reference (or GIS) can be readily prepared and contains a heavy isotope ((18)O)-labeled internal standard for every possible tryptic peptide. Our results showed that the percentage of heavy isotope ((18)O) incorporation applying an improved protocol was >99.5% for most peptides investigated. The accuracy, reproducibility, and linear dynamic range of quantification were further assessed based on known ratios of standard proteins spiked into the labeled mouse plasma reference. Reliable quantification was observed with high reproducibility (i.e. coefficient of variance <10%) for analyte concentrations that were set at 100-fold higher or lower than those of the GIS based on the light ((16)O)/heavy ((18)O) peak area ratios. The utility of (18)O-labeled GIS was further illustrated by accurate relative quantification of 45 major human plasma proteins. Moreover, quantification of the concentrations of C-reactive protein and prostate-specific antigen was illustrated by coupling the GIS with standard additions of purified protein standards. Collectively, our results demonstrated that the use of (18)O-labeled proteome reference as GIS provides a convenient, low cost, and effective strategy for relative quantification of a large number of candidate proteins in biological or clinical samples using SRM.

  4. Domain Walls and Strings in Dense Quark Matter

    NASA Astrophysics Data System (ADS)

    Zhitnitsky, Ariel R.

    2002-12-01

    I discuss several types of domain walls and global strings which occur in colour superconducting quark matter due to the spontaneous violation of relevant U(1) and discrete symmetries. These include the baryon U(1)B, approximate axial U(1)A symmetries as well as an approximate U(1)Y symmetry arising from kaon condensation in colour-flavour locking phase. In this talk I concentrate on discussions of K strings due to their interesting internal structures. Specifically, I demonstrate that under some conditions the global U(1)Y symmetry may not be restored inside the string, in contrast with the standard expectations. Instead, K+ condensation occurs inside the core of the string if a relevant parameter \\cos θ K0 ≡ mK0^2 /μ eff2 is larger than some critical value θK0 ≥ θcrit. If this phenomenon happens, the U(1)Y strings become superconducting and may considerably influence the magnetic properties of dense quark matter, in particular in neutron stars.

  5. [The use of the deuterated internal standard for morphine quantitation for the purpose of doping control by gas chromatography with mass-selective detection].

    PubMed

    Savel'eva, N B; Bykovskaia, N Iu; Dikunets, M A; Bolotov, S L; Rodchenkov, G M

    2010-01-01

    The objective of this study was to demonstrate the possibility to use deuterated compounds as internal standards for the quantitative analysis of morphine by gas chromatography with mass-selective detection for the purpose of doping control. The paper is focused on the problems associated with the use of deuterated morphine-D3 as the internal standard. Quantitative characteristics of the calibration dependence thus documented are presented along with uncertainty values obtained in the measurements with the use of deuterated morphine-D6. An approach to the assessment of method bias associated with the application of morphine-D6 as the deuterated internal standard is described.

  6. Prisms with total internal reflection as solar reflectors

    DOEpatents

    Rabl, Arnulf; Rabl, Veronika

    1978-01-01

    An improved reflective wall for radiant energy collection and concentration devices is provided. The wall is comprised of a plurality of prisms whose frontal faces are adjacent and which reflect the desired radiation by total internal reflection.

  7. Reinforcement mechanism of multi-anchor wall with double wall facing

    NASA Astrophysics Data System (ADS)

    Suzuki, Kouta; Kobayashi, Makoto; Miura, Kinya; Konami, Takeharu; Hayashi, Taketo

    2017-10-01

    The reinforced soil wall has high seismic performance as generally known. However, the seismic behavior has not been clarified accurately yet, especially on multi-anchor wall with double wall facing. Indefinite behavior of reinforced soil wall during earthquake make us complicated in case with adopting to the abutment, because of arrangement of anchor plate as reinforcement often different according to the width of roads. In this study, a series of centrifuge model tests were carried out to investigate the reinforcement mechanism of multi anchor wall with double wall facing from the perspective of the vertical earth pressure. Several types of reinforce arrangement and rigid wall were applied in order to verify the arch function in the reinforced regions. The test results show unique behavior of vertical earth pressure, which was affected by arch action. All the vertical earth pressure placed behind facing panel, are larger than that of middle part between facing panel despite of friction between backfill and facing panel. Similar results were obtained in case using rigid wall. On the other hands, the vertical earth pressure, which were measured at the 3cm high from bottom of model container, shows larger than that of bottom. This results show the existence of arch action between double walls. In addition, it implies that the wall facing of such soil structure confined the backfill as pseudo wall, which is very reason that the multi anchor wall with double wall facing has high seismic performance.

  8. G-structures and domain walls in heterotic theories

    NASA Astrophysics Data System (ADS)

    Lukas, Andre; Matti, Cyril

    2011-01-01

    We consider heterotic string solutions based on a warped product of a four-dimensional domain wall and a six-dimensional internal manifold, preserving two supercharges. The constraints on the internal manifolds with SU(3) structure are derived. They are found to be generalized half-flat manifolds with a particular pattern of torsion classes and they include half-flat manifolds and Strominger's complex non-Kahler manifolds as special cases. We also verify that previous heterotic compactifications on half-flat mirror manifolds are based on this class of solutions.

  9. Methyl malondialdehyde is not suitable as an internal standard for malondialdehyde detection in urine after derivatisation with 2,4-dinitrophenylhydrazine.

    PubMed

    Korchazhkina, Olga; Yang, Ying

    2004-07-05

    A previously described method of measurement of malondialdehyde (MDA) in human urine after derivatisation with 2,4-dinitrophenylhydrazine (DNPH) was tested for a possibility of using methyl malondialdehyde (MeMDA) as an internal standard. Despite structural similarity, those compounds were found to produce different yields of derivatisation under the same conditions depending on urine matrix. We conclude, that MeMDA is not suitable as an internal standard for the measurement of MDA in urine under previously reported conditions when DNPH is used as a deriviatising agent.

  10. 40 CFR 60.4217 - What emission standards must I meet if I am an owner or operator of a stationary internal...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... I am an owner or operator of a stationary internal combustion engine using special fuels? 60.4217... Compression Ignition Internal Combustion Engines Special Requirements § 60.4217 What emission standards must I meet if I am an owner or operator of a stationary internal combustion engine using special fuels...

  11. 40 CFR 60.4217 - What emission standards must I meet if I am an owner or operator of a stationary internal...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... I am an owner or operator of a stationary internal combustion engine using special fuels? 60.4217... Compression Ignition Internal Combustion Engines Special Requirements § 60.4217 What emission standards must I meet if I am an owner or operator of a stationary internal combustion engine using special fuels...

  12. 40 CFR 60.4217 - What emission standards must I meet if I am an owner or operator of a stationary internal...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... I am an owner or operator of a stationary internal combustion engine using special fuels? 60.4217... Compression Ignition Internal Combustion Engines Special Requirements § 60.4217 What emission standards must I meet if I am an owner or operator of a stationary internal combustion engine using special fuels...

  13. The Bulging Behavior of Thick-Walled 6063 Aluminum Alloy Tubes Under Double-Sided Pressures

    NASA Astrophysics Data System (ADS)

    Cui, Xiao-Lei; Wang, Xiao-Song; Yuan, Shi-Jian

    2015-05-01

    To make further exploration on the deformation behavior of tube under double-sided pressures, the thick-walled 6063 aluminum alloy tubes with an outer diameter of 65 mm and an average thickness of 7.86 mm have been used to be bulged under the combined action of internal and external pressures. In the experiment, two ends of the thick-walled tubes were fixed using the tooth and groove match. Three levels of external pressure (0 MPa, 40 MPa, and 80 MPa), in conjunction with the internal pressure, were applied on the tube outside and inside simultaneously. The effect of external pressure on the bulging behavior of the thick-walled tubes, such as the limiting expansion ratio, the bulging zone profile, and the thickness distribution, has been investigated. It is shown that the limiting expansion ratio, the bulging zone profile, and the thickness distribution in the homogeneous bulging area are all insensitive to the external pressure. However, the external pressure can make the thick-walled tube achieve a thinner wall at the fracture area. It reveals that the external pressure can only improve the fracture limit of the thick-walled 6063 tubes, but it has very little effect on their homogeneous bulging behavior. It might be because the external pressure can only increase the magnitude of the hydrostatic pressure for the tube but has no effect on the Lode parameter.

  14. Defining overweight and obesity among Greek children living in Thessaloniki: International versus local reference standards.

    PubMed

    Christoforidis, A; Dimitriadou, M; Papadopolou, E; Stilpnopoulou, D; Katzos, G; Athanassiou-Metaxa, M

    2011-04-01

    Body Mass Index (BMI) offers a simple and reasonable measure of obesity that, with the use of the appropriate reference, can help in the early detection of children with weight problems. Our aim was to compare the two most commonly used international BMI references and the national Greek BMI reference in identifying Greek children being overweight and obese. A group of 1557 children (820 girls and 737 boys, mean age: 11.42 ± 3.51 years) were studied. Weight and height was measured using standard methods, and BMI was calculated. Overweight and obesity were determined using the International Obesity Task Force (IOTF) standards, the Centers for Disease Control and Prevention (CDC) BMI-forage curves and the most recent Greek BMI-for-age curves. RESULTS showed that the IOTF's cut-off limits identifies a significantly higher prevalence of overweight (22.4%) compared with both the CDC's (11.8%, p=0.03) and the Greek's (7.4%, p=0.002) cut-off limits. However, the prevalence of obesity was generally increased when it was determined using the CDC's cut-off limits (13.9%) compared to the prevalence calculated with both the IOTF's (6.5%, p=0.05) and the Greek's (6.9%, n.s.) cut off limits. The use of the national Greek reference standards for BMI underestimates the true prevalence of overweight and obesity. On the contrary, both the IOTF and the CDC standards, although independently, detect an increased number of overweight and obese children and thus they should be adopted in the clinical practice for an earlier identification and a timelier intervention.

  15. Photoelastic Analysis of Cracked Thick Walled Cylinders

    NASA Astrophysics Data System (ADS)

    Pastramă, Ştefan Dan

    2017-12-01

    In this paper, the experimental determination of the stress intensity factor in thick walled cylinders subject to uniform internal pressure and having longitudinal non-penetrating cracks is presented. Photoelastic measurements were used together with the expressions of the stress field near the crack tip for Mode I crack extension and a specific methodology for stress intensity factor determination. Two types of longitudinal cracks - internal and external - were considered. Four plane models were manufactured and analyzed in a plane polariscope at different values of the applied internal pressure. The values of the normalized stress intensity factor were calculated and the results were compared to those reported by other authors. A good accuracy was noticed, showing the reliability of the experimental procedure.

  16. Electromagnetic approaches to wall characterization, wall mitigation, and antenna design for through-the-wall radar systems

    NASA Astrophysics Data System (ADS)

    Thajudeen, Christopher

    Through-the-wall imaging (TWI) is a topic of current interest due to its wide range of public safety, law enforcement, and defense applications. Among the various available technologies such as, acoustic, thermal, and optical imaging, which can be employed to sense and image targets of interest, electromagnetic (EM) imaging, in the microwave frequency bands, is the most widely utilized technology and has been at the forefront of research in recent years. The primary objectives for any Through-the-Wall Radar Imaging (TWRI) system are to obtain a layout of the building and/or inner rooms, detect if there are targets of interest including humans or weapons, determine if there are countermeasures being employed to further obscure the contents of a building or room of interest, and finally to classify the detected targets. Unlike conventional radar scenarios, the presence of walls, made of common construction materials such as brick, drywall, plywood, cinder block, and solid concrete, adversely affects the ability of any conventional imaging technique to properly image targets enclosed within building structures as the propagation through the wall can induce shadowing effects on targets of interest which may result in image degradation, errors in target localization, and even complete target masking. For many applications of TWR systems, the wall ringing signals are strong enough to mask the returns from targets not located a sufficient distance behind the wall, beyond the distance of the wall ringing, and thus without proper wall mitigation, target detection becomes extremely difficult. The results presented in this thesis focus on the development of wall parameter estimation, and intra-wall and wall-type characterization techniques for use in both the time and frequency domains as well as analysis of these techniques under various real world scenarios such as reduced system bandwidth scenarios, various wall backing scenarios, the case of inhomogeneous walls, presence

  17. Symphyseal internal rod fixation versus standard plate fixation for open book pelvic ring injuries: a biomechanical study.

    PubMed

    Osterhoff, G; Tiziani, S; Hafner, C; Ferguson, S J; Simmen, H-P; Werner, C M L

    2016-04-01

    This study investigates the biomechanical stability of a novel technique for symphyseal internal rod fixation (SYMFIX) using a multiaxial spinal screw-rod implant that allows for direct reduction and can be performed percutaneously and compares it to standard internal plate fixation of the symphysis. Standard plate fixation (PLATE, n = 6) and the SYMFIX (n = 6) were tested on pelvic composite models with a simulated open book injury using a universal testing machine. On a previously described testing setup, 500 consecutive cyclic loadings were applied with sinusoidal resulting forces of 200 N. Displacement under loading was measured using an optoelectronic camera system and construct rigidity was calculated as a function of load and displacement. The rigidity of the PLATE construct was 122.8 N/mm (95 % CI: 110.7-134.8), rigidity of the SYMFIX construct 119.3 N/mm (95 % CI: 105.8-132.7). Displacement in the symphyseal area was mean 0.007 mm (95 % CI: 0.003-0.012) in the PLATE group and 0.021 mm (95 % CI: 0.011-0.031) in the SYMFIX group. Displacement in the sacroiliac joint area was mean 0.156 mm (95 % CI: 0.051-0.261) in the PLATE group and 0.120 mm (95 % CI: 0.039-0.201) in the SYMFIX group. In comparison to standard internal plate fixation for the stabilization of open book pelvic ring injuries, symphyseal internal rod fixation using a multiaxial spinal screw-rod implant in vitro shows a similar rigidity and comparable low degrees of displacement.

  18. Protocol for Usability Testing and Validation of the ISO Draft International Standard 19223 for Lung Ventilators

    PubMed Central

    2017-01-01

    Background Clinicians, such as respiratory therapists and physicians, are often required to set up pieces of medical equipment that use inconsistent terminology. Current lung ventilator terminology that is used by different manufacturers contributes to the risk of usage errors, and in turn the risk of ventilator-associated lung injuries and other conditions. Human factors and communication issues are often associated with ventilator-related sentinel events, and inconsistent ventilator terminology compounds these issues. This paper describes our proposed protocol, which will be implemented at the University of Waterloo, Canada when this project is externally funded. Objective We propose to determine whether a standardized vocabulary improves the ease of use, safety, and utility as it relates to the usability of medical devices, compared to legacy medical devices from multiple manufacturers, which use different terms. Methods We hypothesize that usage errors by clinicians will be lower when standardization is consistently applied by all manufacturers. The proposed study will experimentally examine the impact of standardized nomenclature on performance declines in the use of an unfamiliar ventilator product in clinically relevant scenarios. Participants will be respiratory therapy practitioners and trainees, and we propose studying approximately 60 participants. Results The work reported here is in the proposal phase. Once the protocol is implemented, we will report the results in a follow-up paper. Conclusions The proposed study will help us better understand the effects of standardization on medical device usability. The study will also help identify any terms in the International Organization for Standardization (ISO) Draft International Standard (DIS) 19223 that may be associated with recurrent errors. Amendments to the standard will be proposed if recurrent errors are identified. This report contributes a protocol that can be used to assess the effect of

  19. 40 CFR 60.4217 - What emission standards must I meet if I am an owner or operator of a stationary internal...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... I am an owner or operator of a stationary internal combustion engine using special fuels? 60.4217... Compression Ignition Internal Combustion Engines Special Requirements § 60.4217 What emission standards must I meet if I am an owner or operator of a stationary internal combustion engine using special fuels? (a...

  20. 40 CFR 60.4217 - What emission standards must I meet if I am an owner or operator of a stationary internal...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... I am an owner or operator of a stationary internal combustion engine using special fuels? 60.4217... Compression Ignition Internal Combustion Engines Special Requirements § 60.4217 What emission standards must I meet if I am an owner or operator of a stationary internal combustion engine using special fuels? (a...

  1. 3D cardiac wall thickening assessment for acute myocardial infarction

    NASA Astrophysics Data System (ADS)

    Khalid, A.; Chan, B. T.; Lim, E.; Liew, Y. M.

    2017-06-01

    Acute myocardial infarction (AMI) is the most severe form of coronary artery disease leading to localized myocardial injury and therefore irregularities in the cardiac wall contractility. Studies have found very limited differences in global indices (such as ejection fraction, myocardial mass and volume) between healthy subjects and AMI patients, and therefore suggested regional assessment. Regional index, specifically cardiac wall thickness (WT) and thickening is closely related to cardiac function and could reveal regional abnormality due to AMI. In this study, we developed a 3D wall thickening assessment method to identify regional wall contractility dysfunction due to localized myocardial injury from infarction. Wall thickness and thickening were assessed from 3D personalized cardiac models reconstructed from cine MRI images by fitting inscribed sphere between endocardial and epicardial wall. The thickening analysis was performed in 5 patients and 3 healthy subjects and the results were compared against the gold standard 2D late-gadolinium-enhanced (LGE) images for infarct localization. The notable finding of this study is the highly accurate estimation and visual representation of the infarct size and location in 3D. This study provides clinicians with an intuitive way to visually and qualitatively assess regional cardiac wall dysfunction due to infarction in AMI patients.

  2. Functional Competency Development Model for Academic Personnel Based on International Professional Qualification Standards in Computing Field

    ERIC Educational Resources Information Center

    Tumthong, Suwut; Piriyasurawong, Pullop; Jeerangsuwan, Namon

    2016-01-01

    This research proposes a functional competency development model for academic personnel based on international professional qualification standards in computing field and examines the appropriateness of the model. Specifically, the model consists of three key components which are: 1) functional competency development model, 2) blended training…

  3. 25 CFR 543.20 - What are the minimum internal control standards for information technology and information...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... information technology and information technology data? 543.20 Section 543.20 Indians NATIONAL INDIAN GAMING... § 543.20 What are the minimum internal control standards for information technology and information... prevent the concealment of fraud. (4) Information technology agents having access to Class II gaming...

  4. 25 CFR 543.20 - What are the minimum internal control standards for information technology and information...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... information technology and information technology data? 543.20 Section 543.20 Indians NATIONAL INDIAN GAMING... § 543.20 What are the minimum internal control standards for information technology and information... prevent the concealment of fraud. (4) Information technology agents having access to Class II gaming...

  5. Engineering cell wall synthesis mechanism for enhanced PHB accumulation in E. coli.

    PubMed

    Zhang, Xing-Chen; Guo, Yingying; Liu, Xu; Chen, Xin-Guang; Wu, Qiong; Chen, Guo-Qiang

    2018-01-01

    The rigidity of bacterial cell walls synthesized by a complicated pathway limit the cell shapes as coccus, bar or ellipse or even fibers. A less rigid bacterium could be beneficial for intracellular accumulation of poly-3-hydroxybutyrate (PHB) as granular inclusion bodies. To understand how cell rigidity affects PHB accumulation, E. coli cell wall synthesis pathway was reinforced and weakened, respectively. Cell rigidity was achieved by thickening the cell walls via insertion of a constitutive gltA (encoding citrate synthase) promoter in front of a series of cell wall synthesis genes on the chromosome of several E. coli derivatives, resulting in 1.32-1.60 folds increase of Young's modulus in mechanical strength for longer E. coli cells over-expressing fission ring FtsZ protein inhibiting gene sulA. Cell rigidity was weakened by down regulating expressions of ten genes in the cell wall synthesis pathway using CRISPRi, leading to elastic cells with more spaces for PHB accumulation. The regulation on cell wall synthesis changes the cell rigidity: E. coli with thickened cell walls accumulated only 25% PHB while cell wall weakened E. coli produced 93% PHB. Manipulation on cell wall synthesis mechanism adds another possibility to morphology engineering of microorganisms. Copyright © 2017 International Metabolic Engineering Society. Published by Elsevier Inc. All rights reserved.

  6. Occupational health standards. An international comparison.

    PubMed

    Holmberg, B; Winell, M

    1977-03-01

    The background for establishing standards for toxic agents is reviewed, and the standards of 14 different countries, including Sweden, are compared with special reference to criteria and organizational aspects. The differences among countries in the numerical limit values for toxic substances are largely due to differences in definitions, biomedical criteria, technical feasibility and sociopolitical judgements.

  7. Rapid Fabrication Techniques for Liquid Rocket Channel Wall Nozzles

    NASA Technical Reports Server (NTRS)

    Gradl, Paul R.

    2016-01-01

    The functions of a regeneratively-cooled nozzle are to (1) expand combustion gases to increase exhaust gas velocity while, (2) maintaining adequate wall temperatures to prevent structural failure, and (3) transfer heat from the hot gases to the coolant fluid to promote injector performance and stability. Regeneratively-cooled nozzles are grouped into two categories: tube-wall nozzles and channel wall nozzles. A channel wall nozzle is designed with an internal liner containing a series of integral coolant channels that are closed out with an external jacket. Manifolds are attached at each end of the nozzle to distribute coolant to and away from the channels. A variety of manufacturing techniques have been explored for channel wall nozzles, including state of the art laser-welded closeouts and pressure-assisted braze closeouts. This paper discusses techniques that NASA MSFC is evaluating for rapid fabrication of channel wall nozzles that address liner fabrication, slotting techniques and liner closeout techniques. Techniques being evaluated for liner fabrication include large-scale additive manufacturing of freeform-deposition structures to create the liner blanks. Abrasive water jet milling is being evaluated for cutting the complex coolant channel geometries. Techniques being considered for rapid closeout of the slotted liners include freeform deposition, explosive bonding and Cold Spray. Each of these techniques, development work and results are discussed in further detail in this paper.

  8. Calibration of BK Virus Nucleic Acid Amplification Testing to the 1st WHO International Standard for BK Virus

    PubMed Central

    Tan, Susanna K.; Milligan, Stephen; Sahoo, Malaya K.; Taylor, Nathaniel

    2017-01-01

    ABSTRACT Significant interassay variability in the quantification of BK virus (BKV) DNA precludes establishing broadly applicable thresholds for the management of BKV infection in transplantation. The 1st WHO International Standard for BKV (primary standard) was introduced in 2016 as a common calibrator for improving the harmonization of BKV nucleic acid amplification testing (NAAT) and enabling comparisons of biological measurements worldwide. Here, we evaluated the Altona RealStar BKV assay (Altona) and calibrated the results to the international unit (IU) using the Exact Diagnostics BKV verification panel, a secondary standard traceable to the primary standard. The primary and secondary standards on Altona had nearly identical linear regression equations (primary standard, Y = 1.05X − 0.28, R2 = 0.99; secondary standard, Y = 1.04X − 0.26, R2 = 0.99) and conversion factors (primary standard, 1.11 IU/copy; secondary standard, 1.09 IU/copy). A comparison of Altona with a laboratory-developed BKV NAAT assay in IU/ml versus copies/ml using Passing-Bablok regression revealed similar regression lines, no proportional bias, and improvement in the systematic bias (95% confidence interval of intercepts: copies/ml, −0.52 to −1.01; IU/ml, 0.07 to −0.36). Additionally, Bland-Altman analyses revealed a clinically significant reduction of bias when results were reported in IU/ml (IU/ml, −0.10 log10; copies/ml, −0.70 log10). These results indicate that the use of a common calibrator improved the agreement between the two assays. As clinical laboratories worldwide use calibrators traceable to the primary standard to harmonize BKV NAAT results, we anticipate improved interassay comparisons with a potential for establishing broadly applicable quantitative BKV DNA load cutoffs for clinical practice. PMID:28053213

  9. Wind tunnels with adapted walls for reducing wall interference

    NASA Technical Reports Server (NTRS)

    Ganzer, U.

    1979-01-01

    The basic principle of adaptable wind tunnel walls is explained. First results of an investigation carried out at the Aero-Space Institute of Berlin Technical University are presented for two dimensional flexible walls and a NACA 0012 airfoil. With five examples exhibiting very different flow conditions it is demonstrated that it is possible to reduce wall interference and to avoid blockage at transonic speeds by wall adaptation.

  10. Wall shear stress estimation in the aorta: Impact of wall motion, spatiotemporal resolution, and phase noise.

    PubMed

    Zimmermann, Judith; Demedts, Daniel; Mirzaee, Hanieh; Ewert, Peter; Stern, Heiko; Meierhofer, Christian; Menze, Bjoern; Hennemuth, Anja

    2018-04-01

    neglected if wall motion is present. 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  11. A comparison of international occupational therapy competencies: implications for Australian standards in the new millennium.

    PubMed

    Rodger, Sylvia; Clark, Michele; Banks, Rebecca; O'Brien, Mia; Martinez, Kay

    2009-12-01

    A timely evaluation of the Australian Competency Standards for Entry-Level Occupational Therapists (1994) was conducted. This thorough investigation comprised a literature review exploring the concept of competence and the applications of competency standards; systematic benchmarking of the Australian Occupational Therapy Competency Standards (OT AUSTRALIA, 1994) against other national and international competency standards and other affiliated documents, from occupational therapy and other cognate disciplines; and extensive nationwide consultation with the professional community. This paper explores and examines the similarities and disparities between occupational therapy competency standards documents available in English from Australia and other countries. An online search for national occupational therapy competency standards located 10 documents, including the Australian competencies. Four 'frameworks' were created to categorise the documents according to their conceptual underpinnings: Technical-Prescriptive, Enabling, Educational and Meta-Cognitive. Other characteristics that appeared to impact the design, content and implementation of competency standards, including definitions of key concepts, authorship, national and cultural priorities, scope of services, intended use and review mechanisms, were revealed. The proposed 'frameworks' and identification of influential characteristics provided a 'lens' through which to understand and evaluate competency standards. While consistent application of and attention to some of these characteristics appear to consolidate and affirm the authority of competency standards, it is suggested that the national context should be a critical determinant of the design and content of the final document. The Australian Occupational Therapy Competency Standards (OT AUSTRALIA, 1994) are critiqued accordingly, and preliminary recommendations for revision are proposed.

  12. Gold internal standard correction for elemental imaging of soft tissue sections by LA-ICP-MS: element distribution in eye microstructures.

    PubMed

    Konz, Ioana; Fernández, Beatriz; Fernández, M Luisa; Pereiro, Rosario; González, Héctor; Alvarez, Lydia; Coca-Prados, Miguel; Sanz-Medel, Alfredo

    2013-04-01

    Laser ablation coupled to inductively coupled plasma mass spectrometry has been developed for the elemental imaging of Mg, Fe and Cu distribution in histological tissue sections of fixed eyes, embedded in paraffin, from human donors (cadavers). This work presents the development of a novel internal standard correction methodology based on the deposition of a homogeneous thin gold film on the tissue surface and the use of the (197)Au(+) signal as internal standard. Sample preparation (tissue section thickness) and laser conditions were carefully optimized, and internal normalisation using (197)Au(+) was compared with (13)C(+) correction for imaging applications. (24)Mg(+), (56)Fe(+) and (63)Cu(+) distributions were investigated in histological sections of the anterior segment of the eye (including the iris, ciliary body, cornea and trabecular meshwork) and were shown to be heterogeneously distributed along those tissue structures. Reproducibility was assessed by imaging different human eye sections from the same donor and from ten different eyes from adult normal donors, which showed that similar spatial maps were obtained and therefore demonstrate the analytical potential of using (197)Au(+) as internal standard. The proposed analytical approach could offer a robust tool with great practical interest for clinical studies, e.g. to investigate trace element distribution of metals and their alterations in ocular diseases.

  13. A universal standard for the validation of blood pressure measuring devices: Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Collaboration Statement.

    PubMed

    Stergiou, George S; Alpert, Bruce; Mieke, Stephan; Asmar, Roland; Atkins, Neil; Eckert, Siegfried; Frick, Gerhard; Friedman, Bruce; Graßl, Thomas; Ichikawa, Tsutomu; Ioannidis, John P; Lacy, Peter; McManus, Richard; Murray, Alan; Myers, Martin; Palatini, Paolo; Parati, Gianfranco; Quinn, David; Sarkis, Josh; Shennan, Andrew; Usuda, Takashi; Wang, Jiguang; Wu, Colin O; O'Brien, Eoin

    2018-03-01

    : In the last 30 years, several organizations, such as the US Association for the Advancement of Medical Instrumentation (AAMI), the British Hypertension Society, the European Society of Hypertension (ESH) Working Group on Blood Pressure (BP) Monitoring and the International Organization for Standardization (ISO) have developed protocols for clinical validation of BP measuring devices. However, it is recognized that science, as well as patients, consumers and manufacturers would be best served if all BP measuring devices were assessed for accuracy according to an agreed single validation protocol that had global acceptance. Therefore, an international initiative was taken by AAMI, ESH and ISO experts who agreed to develop a universal standard for device validation. This statement presents the key aspects of a validation procedure, which were agreed by the AAMI, ESH and ISO representatives as the basis for a single universal validation protocol. As soon as the AAMI/ESH/ISO standard is fully developed, this will be regarded as the single universal standard and will replace all other previous standards/protocols.

  14. A Universal Standard for the Validation of Blood Pressure Measuring Devices: Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Collaboration Statement.

    PubMed

    Stergiou, George S; Alpert, Bruce; Mieke, Stephan; Asmar, Roland; Atkins, Neil; Eckert, Siegfried; Frick, Gerhard; Friedman, Bruce; Graßl, Thomas; Ichikawa, Tsutomu; Ioannidis, John P; Lacy, Peter; McManus, Richard; Murray, Alan; Myers, Martin; Palatini, Paolo; Parati, Gianfranco; Quinn, David; Sarkis, Josh; Shennan, Andrew; Usuda, Takashi; Wang, Jiguang; Wu, Colin O; O'Brien, Eoin

    2018-03-01

    In the past 30 years, several organizations, such as the US Association for the Advancement of Medical Instrumentation (AAMI), the British Hypertension Society, the European Society of Hypertension (ESH) Working Group on Blood Pressure (BP) Monitoring, and the International Organization for Standardization (ISO), have developed protocols for clinical validation of BP measuring devices. However, it is recognized that science, as well as patients, consumers, and manufacturers, would be best served if all BP measuring devices were assessed for accuracy according to an agreed single validation protocol that had global acceptance. Therefore, an international initiative was taken by the AAMI, ESH, and ISO experts who agreed to develop a universal standard for device validation. This statement presents the key aspects of a validation procedure, which were agreed by the AAMI, ESH, and ISO representatives as the basis for a single universal validation protocol. As soon as the AAMI/ESH/ISO standard is fully developed, this will be regarded as the single universal standard and will replace all other previous standards/protocols. © 2018 American Heart Association, Inc., and Wolters Kluwer Health, Inc.

  15. Kolmogorov Behavior of Near-Wall Turbulence and Its Application in Turbulence Modeling

    NASA Technical Reports Server (NTRS)

    Shih, Tsan-Hsing; Lumley, John L.

    1992-01-01

    The near-wall behavior of turbulence is re-examined in a way different from that proposed by Hanjalic and Launder and followers. It is shown that at a certain distance from the wall, all energetic large eddies will reduce to Kolmogorov eddies (the smallest eddies in turbulence). All the important wall parameters, such as friction velocity, viscous length scale, and mean strain rate at the wall, are characterized by Kolmogorov microscales. According to this Kolmogorov behavior of near-wall turbulence, the turbulence quantities, such as turbulent kinetic energy, dissipation rate, etc. at the location where the large eddies become Kolmogorov eddies, can be estimated by using both direct numerical simulation (DNS) data and asymptotic analysis of near-wall turbulence. This information will provide useful boundary conditions for the turbulent transport equations. As an example, the concept is incorporated in the standard k-epsilon model which is then applied to channel and boundary flows. Using appropriate boundary conditions (based on Kolmogorov behavior of near-wall turbulence), there is no need for any wall-modification to the k-epsilon equations (including model constants). Results compare very well with the DNS and experimental data.

  16. A Comprehensive Review of Spirit Drink Safety Standards and Regulations from an International Perspective.

    PubMed

    Pang, Xiao-Na; Li, Zhao-Jie; Chen, Jing-Yu; Gao, Li-Juan; Han, Bei-Zhong

    2017-03-01

    Standards and regulations related to spirit drinks have been established by different countries and international organizations to ensure the safety and quality of spirits. Here, we introduce the principles of food safety and quality standards for alcoholic beverages and then compare the key indicators used in the distinct standards of the Codex Alimentarius Commission, the European Union, the People's Republic of China, the United States, Canada, and Australia. We also discuss in detail the "maximum level" of the following main contaminants of spirit drinks: methanol, higher alcohols, ethyl carbamate, hydrocyanic acid, heavy metals, mycotoxins, phthalates, and aldehydes. Furthermore, the control measures used for potential hazards are introduced. Harmonization of the current requirements based on comprehensive scope analysis and the risk assessment approach will enhance both the trade and quality of distilled spirits. This review article provides valuable information that will enable producers, traders, governments, and researchers to increase their knowledge of spirit drink safety requirements, control measures, and research trends.

  17. Collaborative study for the establishment of the 2(nd) International Standard for Bleomycin Complex A2/B2.

    PubMed

    Jorajuria, S; Raphalen, C; Dujardin, V; Daas, A

    2015-01-01

    Organization (WHO) International Standard (IS) for bleomycin complex A2/B2. Eight laboratories from different countries participated. Potencies of the candidate material were estimated by microbiological assays with sensitive micro-organisms. To ensure continuity between consecutive batches, the 1(st) IS for bleomycin complex A2/B2 was used as a reference. Based on the results of the study, the 2(nd) IS for bleomycin complex A2/B2 was adopted at the meeting of the WHO Expert Committee for Biological Standardization (ECBS) in 2014 with an assigned potency of 12 500 International Units (IU) per vial. The 2(nd) IS for bleomycin complex A2/B2 is available from the European Directorate for the Quality of Medicines & HealthCare (EDQM).

  18. Multiple internal standard normalization for improving HS-SPME-GC-MS quantitation in virgin olive oil volatile organic compounds (VOO-VOCs) profile.

    PubMed

    Fortini, Martina; Migliorini, Marzia; Cherubini, Chiara; Cecchi, Lorenzo; Calamai, Luca

    2017-04-01

    The commercial value of virgin olive oils (VOOs) strongly depends on their classification, also based on the aroma of the oils, usually evaluated by a panel test. Nowadays, a reliable analytical method is still needed to evaluate the volatile organic compounds (VOCs) and support the standard panel test method. To date, the use of HS-SPME sampling coupled to GC-MS is generally accepted for the analysis of VOCs in VOOs. However, VOO is a challenging matrix due to the simultaneous presence of: i) compounds at ppm and ppb concentrations; ii) molecules belonging to different chemical classes and iii) analytes with a wide range of molecular mass. Therefore, HS-SPME-GC-MS quantitation based upon the use of external standard method or of only a single internal standard (ISTD) for data normalization in an internal standard method, may be troublesome. In this work a multiple internal standard normalization is proposed to overcome these problems and improving quantitation of VOO-VOCs. As many as 11 ISTDs were used for quantitation of 71 VOCs. For each of them the most suitable ISTD was selected and a good linearity in a wide range of calibration was obtained. Except for E-2-hexenal, without ISTD or with an unsuitable ISTD, the linear range of calibration was narrower with respect to that obtained by a suitable ISTD, confirming the usefulness of multiple internal standard normalization for the correct quantitation of VOCs profile in VOOs. The method was validated for 71 VOCs, and then applied to a series of lampante virgin olive oils and extra virgin olive oils. In light of our results, we propose the application of this analytical approach for routine quantitative analyses and to support sensorial analysis for the evaluation of positive and negative VOOs attributes. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Controlling depinning and propagation of single domain-walls in magnetic microwires

    NASA Astrophysics Data System (ADS)

    Jiménez, Alejandro; del Real, Rafael P.; Vázquez, Manuel

    2013-03-01

    The magnetization reversal in magnetostrictive amorphous microwires takes place by depinning and propagation of a single domain wall. This is a consequence of the particular domain structure determined by the strong uniaxial anisotropy from the reinforcement of magnetoelastic and shape contributions. In the present study, after an overview on the current state-of-the art on the topic, we introduce the general behaviour of single walls in 30 to 40 cm long Fe-base microwires propagating under homogeneous field. Depending on the way the walls are generated, we distinguish among three different walls namely, standard wall, DWst, depinned and propagating from the wire's end under homogeneous field which motion is the first one to switch on; reverse wall, DWrev, propagating from the opposite end under non-homogeneous field, and defect wall, DWdef, nucleated around local defect. Both, DWrev and DWdef are observed only under large enough applied field. In the subsequent section, we study the propagation of a wall under applied field smaller than the switching field. There, we conclude that a minimum field, Hdep,0, is needed to depin the DWst, as well as that a minimum field, Hprop,0, is required for the wall to propagate long distances. In the last section, we analyse the shape of induced signals in the pickup coils upon the crossing of the walls and its correlation to the domain walls shape. We conclude that length and shape of the wall are significantly distorted by the fact that the wall is typically as long as the measuring coils. Contribution to the Topical Issue "New Trends in Magnetism and Magnetic Materials", edited by Francesca Casoli, Massimo Solzi and Paola Tiberto.

  20. Internal standards for use in the comprehensive analysis of polychlorinated aromatic hydrocarbons using gas chromatography combined with multiphoton ionization mass spectrometry.

    PubMed

    Li, Adan; Imasaka, Totaro

    2016-10-28

    To decrease health-risks to humans, non-toxic compounds were evaluated for use as internal standards for calibrating data obtained by gas chromatography/multiphoton ionization mass spectrometry (GC-MPI-MS) using an ultraviolet femtosecond laser as the ionization source. The retention time in the mass chromatogram was calibrated using a retention index, in which a series of n-alkanes was employed as internal standards for evaluating the retention times for polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and polychlorinated biphenyls (PCBs). To compensate for changes in signal intensity in MPI-MS, the dependence of signal intensity on the laser pulse energy was investigated for the dioxin-like compounds, in addition to five non-toxic aromatic hydrocarbons, that were used as internal standards. Based on their similar behavior,the non-toxic PCDD/PCDF, its 13 C-isotope, and pentachlorobenzene behave similarly, we conclude that they can be used for calibrating the signal intensities in MPI-MS. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. On fully three-dimensional resistive wall mode and feedback stabilization computations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strumberger, E.; Merkel, P.; Sempf, M.

    2008-05-15

    Resistive walls, located close to the plasma boundary, reduce the growth rates of external kink modes to resistive time scales. For such slowly growing resistive wall modes, the stabilization by an active feedback system becomes feasible. The fully three-dimensional stability code STARWALL, and the feedback optimization code OPTIM have been developed [P. Merkel and M. Sempf, 21st IAEA Fusion Energy Conference 2006, Chengdu, China (International Atomic Energy Agency, Vienna, 2006, paper TH/P3-8] to compute the growth rates of resistive wall modes in the presence of nonaxisymmetric, multiply connected wall structures and to model the active feedback stabilization of these modes.more » In order to demonstrate the capabilities of the codes and to study the effect of the toroidal mode coupling caused by multiply connected wall structures, the codes are applied to test equilibria using the resistive wall structures currently under debate for ITER [M. Shimada et al., Nucl. Fusion 47, S1 (2007)] and ASDEX Upgrade [W. Koeppendoerfer et al., Proceedings of the 16th Symposium on Fusion Technology, London, 1990 (Elsevier, Amsterdam, 1991), Vol. 1, p. 208].« less

  2. On fully three-dimensional resistive wall mode and feedback stabilization computationsa)

    NASA Astrophysics Data System (ADS)

    Strumberger, E.; Merkel, P.; Sempf, M.; Günter, S.

    2008-05-01

    Resistive walls, located close to the plasma boundary, reduce the growth rates of external kink modes to resistive time scales. For such slowly growing resistive wall modes, the stabilization by an active feedback system becomes feasible. The fully three-dimensional stability code STARWALL, and the feedback optimization code OPTIM have been developed [P. Merkel and M. Sempf, 21st IAEA Fusion Energy Conference 2006, Chengdu, China (International Atomic Energy Agency, Vienna, 2006, paper TH/P3-8] to compute the growth rates of resistive wall modes in the presence of nonaxisymmetric, multiply connected wall structures and to model the active feedback stabilization of these modes. In order to demonstrate the capabilities of the codes and to study the effect of the toroidal mode coupling caused by multiply connected wall structures, the codes are applied to test equilibria using the resistive wall structures currently under debate for ITER [M. Shimada et al., Nucl. Fusion 47, S1 (2007)] and ASDEX Upgrade [W. Köppendörfer et al., Proceedings of the 16th Symposium on Fusion Technology, London, 1990 (Elsevier, Amsterdam, 1991), Vol. 1, p. 208].

  3. Overweight and Obesity among Children (10-13 years) in Bahrain:A comparison between Two International Standards

    PubMed Central

    O. Musaiger, Abdulrahman; Al-Mannai, Mariam; Al-Marzog, Qazi

    2014-01-01

    Objective: Obesity has become one of the main public health problems worldwide. Childhood obesity rate is growing very fast in both developed and developing countries. This paper aimed to explore the prevalence of overweight and obesity among school children aged 10-13 years in Bahrain, and to find out the difference in this prevalence when using two international standards. Methods: A multistage stratified sampling procedure was used to select 2146 students (1068 males, 1078 females) from public schools in Bahrain. Weight and height were measured and Body Mass Index for age and sex was calculated to determine the obesity levels. Both International Obesity Task Force (IOTF) and World Health Organization (WHO) references were used to determine the prevalence of overweight and obesity. Results: The findings revealed that the prevalence of overweight and obesity ranged from 15.7% to 28.9% among males and from 21.1% to 30.7% among females. The WHO reference standard provided higher prevalence of overweight and obesity than IOTF reference. Conclusion: The study confirmed that obesity is a problem of concern in Bahraini school children and calls for intervention programme to combat obesity in schools. However, the standard used to determine obesity levels should be carefully selected and interpreted. PMID:24948966

  4. Defining overweight and obesity among Greek children living in Thessaloniki: International versus local reference standards

    PubMed Central

    Christoforidis, A; Dimitriadou, M; Papadopolou, E; Stilpnopoulou, D; Katzos, G; Athanassiou-Metaxa, M

    2011-01-01

    Background: Body Mass Index (BMI) offers a simple and reasonable measure of obesity that, with the use of the appropriate reference, can help in the early detection of children with weight problems. Our aim was to compare the two most commonly used international BMI references and the national Greek BMI reference in identifying Greek children being overweight and obese. Methods: A group of 1557 children (820 girls and 737 boys, mean age: 11.42 ± 3.51 years) were studied. Weight and height was measured using standard methods, and BMI was calculated. Overweight and obesity were determined using the International Obesity Task Force (IOTF) standards, the Centers for Disease Control and Prevention (CDC) BMI-forage curves and the most recent Greek BMI-for-age curves. Results: Results showed that the IOTF's cut-off limits identifies a significantly higher prevalence of overweight (22.4%) compared with both the CDC's (11.8%, p=0.03) and the Greek's (7.4%, p=0.002) cut-off limits. However, the prevalence of obesity was generally increased when it was determined using the CDC's cut-off limits (13.9%) compared to the prevalence calculated with both the IOTF's (6.5%, p=0.05) and the Greek's (6.9%, n.s.) cut off limits. Conclusions: The use of the national Greek reference standards for BMI underestimates the true prevalence of overweight and obesity. On the contrary, both the IOTF and the CDC standards, although independently, detect an increased number of overweight and obese children and thus they should be adopted in the clinical practice for an earlier identification and a timelier intervention. PMID:22110296

  5. Capturing strain localization behind a geosynthetic-reinforced soil wall

    NASA Astrophysics Data System (ADS)

    Lai, Timothy Y.; Borja, Ronaldo I.; Duvernay, Blaise G.; Meehan, Richard L.

    2003-04-01

    This paper presents the results of finite element (FE) analyses of shear strain localization that occurred in cohesionless soils supported by a geosynthetic-reinforced retaining wall. The innovative aspects of the analyses include capturing of the localized deformation and the accompanying collapse mechanism using a recently developed embedded strong discontinuity model. The case study analysed, reported in previous publications, consists of a 3.5-m tall, full-scale reinforced wall model deforming in plane strain and loaded by surcharge at the surface to failure. Results of the analysis suggest strain localization developing from the toe of the wall and propagating upward to the ground surface, forming a curved failure surface. This is in agreement with a well-documented failure mechanism experienced by the physical wall model showing internal failure surfaces developing behind the wall as a result of the surface loading. Important features of the analyses include mesh sensitivity studies and a comparison of the localization properties predicted by different pre-localization constitutive models, including a family of three-invariant elastoplastic constitutive models appropriate for frictional/dilatant materials. Results of the analysis demonstrate the potential of the enhanced FE method for capturing a collapse mechanism characterized by the presence of a failure, or slip, surface through earthen materials.

  6. A vertical wall in the Whittard Canyon with a novel community assemblage

    NASA Astrophysics Data System (ADS)

    Johnson, Mark; White, Martin; Wilson, Annette; Wuerzberg, Laura; Schwabe, Enrico; Folch, Helka; Allcock, Louise

    2013-04-01

    We describe a hitherto unreported community from a vertical wall in the Whittard Canyon system on the Atlantic Margin. The wall extended vertically for about 100 m from approximately 750 m depth. We explored the wall with an ROV and discovered an assemblage cominated by large limid bivalves Acesta excavata and deep-water oysters Neopycnodonte zibrowii at very high densities, particularly at overhangs. The assemblage also contained deep-water corals (including solitary corals). It had high numbers of flytrap anemones and had many mobile species associated with it including crustaceans such as Paramola cuvieri and Bathynectes longispina, echinoderms and fishes. We took CTD transects in the area of the wall and beam attenuation indicated nepheloid layers present in the water column. The greatest densities of suspended material at the ROV dive site were at the depth of the wall. We hypothesise that internal waves concentrate suspended sediment at the foot of the vertical wall. This may provide the resources to support the high density of large filter feeders at these depths.

  7. The CARE International Evaluation Standards

    ERIC Educational Resources Information Center

    Rugh, Jim

    2004-01-01

    The 1996 American Evaluation Association conference in Atlanta featured a session on strategies to promote monitoring and evaluation (M&E) in international nongovernmental organizations (INGOs). At that time, there was a lengthy list of proposed initiatives to be undertaken in CARE. With the perspective of hindsight and reviewing the…

  8. Mass spectrometric real-time monitoring of an enzymatic phosphorylation assay using internal standards and data-handling freeware.

    PubMed

    Krappmann, Michael; de Boer, Arjen R; Kool, Daniël R W; Irth, Hubertus; Letzel, Thomas

    2016-04-30

    Continuous-flow reaction detection systems (monitoring enzymatic reactions with mass spectrometry (MS)) lack quantitative values so far. Therefore, two independent internal standards (IS) are implemented in a way that the online system stability can be observed, quantitative conversion values for substrate and product can be obtained and they can be used as mass calibration standards for high MS accuracy. An application previously developed for the MS detection of peptide phosphorylation by cAMP-dependent protein kinase A (PKA) (De Boer et al., Anal. Bioanal. Chem. 2005, 381, 647-655) was transferred to a continuous-flow reaction detection system. This enzymatic reaction, involving enzyme activation as well as the transfer of a phosphate group from ATP to a peptide substrate, was used to prove the compatibility of a quantitative enzymatic assay in a continuous-flow real-time system (connected to MS). Moreover (using internal standards), the critical parameter reaction temperature (including solution density variations depending on temperature) was studied in the continuous-flow mixing system. Furthermore, two substrates (malantide and kemptide), two enzyme types (catalytic subunit of PKA and complete PKA) and one inhibitor were tested to determine system robustness and long-term availability. Even spraying solutions that contained significant amount of MS contaminants (e.g. the polluted catalytic subunit) resulted in quantifiable MS signal intensities. Subsequent recalculations using the internal standards led to results representing the power of this application. The presented methodology and the data evaluation with available Achroma freeware enable the direct coupling of biochemical assays with quantitative MS detection. Monitoring changes such as temperature, reaction time, inhibition, or compound concentrations can be observed quantitatively and thus enzymatic activity can be calculated. Copyright © 2016 John Wiley & Sons, Ltd.

  9. Spontaneous Behaviors and Wall-Curvature Lead to Apparent Wall Preference in Planarian.

    PubMed

    Akiyama, Yoshitaro; Agata, Kiyokazu; Inoue, Takeshi

    2015-01-01

    The planarian Dugesia japonica tends to stay near the walls of its breeding containers and experimental dishes in the laboratory, a phenomenon called "wall preference". This behavior is thought to be important for environmental adaptation, such as hiding by planarians in nature. However, the mechanisms regulating wall-preference behavior are not well understood, since this behavior occurs in the absence of any particular stimulation. Here we show the mechanisms of wall-preference behavior. Surprisingly, planarian wall-preference behavior was also shown even by the head alone and by headless planarians. These results indicate that planarian "wall-preference" behavior only appears to be a "preference" behavior, and is actually an outcome of spontaneous behaviors, rather than of brain function. We found that in the absence of environmental cues planarians moved basically straight ahead until they reached a wall, and that after reaching a wall, they changed their direction of movement to one tangential to the wall, suggesting that this spontaneous behavior may play a critical role in the wall preference. When we tested another spontaneous behavior, the wigwag movement of the planarian head, using computer simulation with various wigwag angles and wigwag intervals, large wigwag angle and short wigwag interval reduced wall-preference behavior. This indicated that wigwag movement may determine the probability of staying near the wall or leaving the wall. Furthermore, in accord with this simulation, when we tested planarian wall-preference behavior using several assay fields with different curvature of the wall, we found that concavity and sharp curvature of walls negatively impacted wall preference by affecting the permissible angle of the wigwag movement. Together, these results indicate that planarian wall preference may be involuntarily caused by the combination of two spontaneous planarian behaviors: moving straight ahead until reaching a wall and then moving along it

  10. Systems Modeling of a Hypothetical SSME Channel-Wall Nozzle

    NASA Technical Reports Server (NTRS)

    Greene, William D.; Thames, Mignon P.; Polsgrove, Robert H.

    2003-01-01

    A future upgrade to the Space Shuttle Main Engine (SSME) may be the replacement of the current regenerative cooled tube-wall nozzle with a nozzle using a regeneratively-cooled channel-wall design. The current tube-wall design represents the only major piece of SSME hardware that has not been dramatically updated throughout thc long history of the engine. There are a number of advantages to a channel-wall design including the promise of faster and lower cost fabrication and greater reliability in the field. The technical obstacles in the path of making this happen are many, particularly in the realms of metallurgy and manufacturing techniques. However, one technical area that can and should be addressed in the near term as part of the development of detailed component requirements is a systems type model of the fluid flow and heat transfer processes to which the new design will be exposed. This paper presents the results of an effort to develop a mathematical model of the internal flow for a generic channel-wall nozzle functioning as a direct replacement for the current tube-wall nozzle with a minimum of systems-level changes. Comparisons will be made to mathematical modeling results for the current tube-wall design and the results of various geometrical trade studies will be presented. It is the intent of this work to examine the feasibility of the concept of a direct replacement component with minimum systems-!eve impacts and to highlight potential areas of concern requiring further work in the future.

  11. Evaluation of the impact of matrix effect on quantification of pesticides in foods by gas chromatography-mass spectrometry using isotope-labeled internal standards.

    PubMed

    Yarita, Takashi; Aoyagi, Yoshie; Otake, Takamitsu

    2015-05-29

    The impact of the matrix effect in GC-MS quantification of pesticides in food using the corresponding isotope-labeled internal standards was evaluated. A spike-and-recovery study of nine target pesticides was first conducted using paste samples of corn, green soybean, carrot, and pumpkin. The observed analytical values using isotope-labeled internal standards were more accurate for most target pesticides than that obtained using the external calibration method, but were still biased from the spiked concentrations when a matrix-free calibration solution was used for calibration. The respective calibration curves for each target pesticide were also prepared using matrix-free calibration solutions and matrix-matched calibration solutions with blank soybean extract. The intensity ratio of the peaks of most target pesticides to that of the corresponding isotope-labeled internal standards was influenced by the presence of the matrix in the calibration solution; therefore, the observed slope varied. The ratio was also influenced by the type of injection method (splitless or on-column). These results indicated that matrix-matching of the calibration solution is required for very accurate quantification, even if isotope-labeled internal standards were used for calibration. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Blood Flow Characterization According to Linear Wall Models of the Carotid Bifurcation

    NASA Astrophysics Data System (ADS)

    Williamson, Shobha; Rayz, Vitaliy; Berger, Stanley; Saloner, David

    2004-11-01

    Previous studies of the arterial wall include linearly isotropic, isotropic with residual stresses, and anisotropic models. This poses the question of how the results of each method differ when coupled with flow. Hence, the purpose of this study was to compare flow for these material models and subsequently determine if variations exist. Results show that displacement at the bifurcation and internal carotid bulb was noticeably larger in the orthotropic versus the isotropic model with subtle differences toward the inlet and outlets, which are fixed in space. In general, the orthotropic wall is further distended than the isotropic wall for the entire cycle. This apparent distention of the orthotropic wall clearly affects the flow. In diastole, the combination of slower flow and larger wall distention due to lumen pressure creates a sinuous velocity profile, particularly in the orthotropic model where the recirculation zone created displaces the core flow to a smaller area thereby increasing the velocity magnitudes nearly 60

  13. A New Evaluation Method of Stored Heat Effect of Reinforced Concrete Wall of Cold Storage

    NASA Astrophysics Data System (ADS)

    Nomura, Tomohiro; Murakami, Yuji; Uchikawa, Motoyuki

    Today it has become imperative to save energy by operating a refrigerator in a cold storage executed by external insulate reinforced concrete wall intermittently. The theme of the paper is to get the evaluation method to be capable of calculating, numerically, interval time for stopping the refrigerator, in applying reinforced concrete wall as source of stored heat. The experiments with the concrete models were performed in order to examine the time variation of internal temperature after refrigerator stopped. In addition, the simulation method with three dimensional unsteady FEM for personal-computer type was introduced for easily analyzing the internal temperature variation. Using this method, it is possible to obtain the time variation of internal temperature and to calculate the interval time for stopping the refrigerator.

  14. Preliminary report on the International Conference for the Development of Standards for the Treatment of Anorectal Malformations.

    PubMed

    Holschneider, Alexander; Hutson, John; Peña, Albert; Beket, Elhamy; Chatterjee, Subir; Coran, Arnold; Davies, Michael; Georgeson, Keith; Grosfeld, Jay; Gupta, Devendra; Iwai, Naomi; Kluth, Dieter; Martucciello, Giuseppe; Moore, Samuel; Rintala, Risto; Smith, E Durham; Sripathi, D V; Stephens, Douglas; Sen, Sudipta; Ure, Benno; Grasshoff, Sabine; Boemers, Thomas; Murphy, Feilin; Söylet, Yunus; Dübbers, Martin; Kunst, Marc

    2005-10-01

    Anorectal malformations (ARM) are common congenital anomalies seen throughout the world. Comparison of outcome data has been hindered because of confusion related to classification and assessment systems. The goals of the Krinkenbeck Conference on ARM was to develop standards for an International Classification of ARM based on a modification of fistula type and adding rare and regional variants, and design a system for comparable follow up studies. Lesions were classified into major clinical groups based on the fistula location (perineal, recto-urethral, recto-vesical, vestibular), cloacal lesions, those with no fistula and anal stenosis. Rare and regional variants included pouch colon, rectal atresia or stenosis, rectovaginal fistula, H-fistula and others. Groups would be analyzed according to the type of procedure performed stratified for confounding associated conditions such as sacral anomalies and tethered cord. A standard method for postoperative assessment of continence was determined. A new International diagnostic classification system, operative groupings and a method of postoperative assessment of continence was developed by consensus of a large contingent of participants experienced in the management of patients with ARM. These methods should allow for a common standardization of diagnosis and comparing postoperative results.

  15. Wall shear stress measurement in blade end-wall corner region

    NASA Technical Reports Server (NTRS)

    Bhargava, R.; Raj, R.; Boldman, D. R.

    1987-01-01

    The magnitude and the direction of wall shear stress and surface pressure in the blade end-wall corner region were investigated. The measurements were obtained on a specially designed Preston tube, the tip of which could be concentrically rotated about its axis of rotation at the measurement location. The magnitude of wall shear stress in the vicinity of the corner was observed to increase significantly (170 percent) compared to its far-upstream value; the increase was consistently higher on the blade surface compared to the value on the plate surface of the blade end-wall corner. On both surfaces in the blade end-wall corner, the variation of the wall shear stress direction was found to be more predominant in the vicinity of the blade leading-edge location. The trend of the measured wall shear stress direction showed good agreement with the limiting streamline directions obtained from the flow visualization studies.

  16. 77 FR 4278 - Light-Walled Rectangular Pipe and Tube From Turkey: Extension of Time Limits for Preliminary...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-27

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-489-815] Light-Walled Rectangular Pipe and Tube From Turkey: Extension of Time Limits for Preliminary Results of Antidumping Duty..., light- walled rectangular pipe and tube from Turkey for the May 1, 2010, through April 30, 2011, period...

  17. Wall-based identification of coherent structures in wall-bounded turbulence

    NASA Astrophysics Data System (ADS)

    Sanmiguel Vila, C.; Flores, O.

    2018-04-01

    During the last decades, a number of reduced order models based on coherent structures have been proposed to describe wall-bounded turbulence. Many of these models emphasize the importance of coherent wall-normal velocity eddies (ν-eddies), which drive the generation of the very long streamwise velocity structures observed in the logarithmic and outer region. In order to use these models to improve our ability to control wall-bounded turbulence in realistic applications, these ν-eddies need to be identified from the wall in a non-intrusive way. In this paper, the possibility of using the pressure signal at the wall to identify these ν-eddies is explored, analyzing the cross-correlation between the wall-normal velocity component and the pressure fluctuations at the wall in a DNS of a turbulent channel flow at Reτ = 939. The results show that the cross-correlation has a region of negative correlation upstream, and a region of positive correlation backwards. In the spanwise direction the correlation decays monotonously, except very close to the wall where a change of sign of the correlation coefficient is observed. Moreover, filtering the pressure fluctuations at the wall in space results in an increase of the region where the cross-correlation is strong, both for the positively and the negatively correlated regions. The use of a time filter for the pressure fluctuations at the wall yields different results, displacing the regions of strong correlation without changing much their sizes. The results suggest that space-filtering the pressure at the wall is a feasible way to identify ν-eddies of different sizes, which could be used to trigger turbulent control strategies.

  18. Internal Corrosion Direct Assessment Detection of Water (WP #205)

    DOT National Transportation Integrated Search

    2010-12-12

    Internal corrosion of natural gas pipelines is the result of interaction between the inside pipe wall and impurities in the product being transported. Such interactions can lead to an overall loss of material thereby thinning the pipe wall and thus r...

  19. Spontaneous Behaviors and Wall-Curvature Lead to Apparent Wall Preference in Planarian

    PubMed Central

    Akiyama, Yoshitaro; Agata, Kiyokazu; Inoue, Takeshi

    2015-01-01

    The planarian Dugesia japonica tends to stay near the walls of its breeding containers and experimental dishes in the laboratory, a phenomenon called “wall preference”. This behavior is thought to be important for environmental adaptation, such as hiding by planarians in nature. However, the mechanisms regulating wall-preference behavior are not well understood, since this behavior occurs in the absence of any particular stimulation. Here we show the mechanisms of wall-preference behavior. Surprisingly, planarian wall-preference behavior was also shown even by the head alone and by headless planarians. These results indicate that planarian “wall-preference” behavior only appears to be a “preference” behavior, and is actually an outcome of spontaneous behaviors, rather than of brain function. We found that in the absence of environmental cues planarians moved basically straight ahead until they reached a wall, and that after reaching a wall, they changed their direction of movement to one tangential to the wall, suggesting that this spontaneous behavior may play a critical role in the wall preference. When we tested another spontaneous behavior, the wigwag movement of the planarian head, using computer simulation with various wigwag angles and wigwag intervals, large wigwag angle and short wigwag interval reduced wall-preference behavior. This indicated that wigwag movement may determine the probability of staying near the wall or leaving the wall. Furthermore, in accord with this simulation, when we tested planarian wall-preference behavior using several assay fields with different curvature of the wall, we found that concavity and sharp curvature of walls negatively impacted wall preference by affecting the permissible angle of the wigwag movement. Together, these results indicate that planarian wall preference may be involuntarily caused by the combination of two spontaneous planarian behaviors: moving straight ahead until reaching a wall and then

  20. Domain wall nanoelectronics

    NASA Astrophysics Data System (ADS)

    Catalan, G.; Seidel, J.; Ramesh, R.; Scott, J. F.

    2012-01-01

    Domains in ferroelectrics were considered to be well understood by the middle of the last century: They were generally rectilinear, and their walls were Ising-like. Their simplicity stood in stark contrast to the more complex Bloch walls or Néel walls in magnets. Only within the past decade and with the introduction of atomic-resolution studies via transmission electron microscopy, electron holography, and atomic force microscopy with polarization sensitivity has their real complexity been revealed. Additional phenomena appear in recent studies, especially of magnetoelectric materials, where functional properties inside domain walls are being directly measured. In this paper these studies are reviewed, focusing attention on ferroelectrics and multiferroics but making comparisons where possible with magnetic domains and domain walls. An important part of this review will concern device applications, with the spotlight on a new paradigm of ferroic devices where the domain walls, rather than the domains, are the active element. Here magnetic wall microelectronics is already in full swing, owing largely to the work of Cowburn and of Parkin and their colleagues. These devices exploit the high domain wall mobilities in magnets and their resulting high velocities, which can be supersonic, as shown by Kreines’ and co-workers 30 years ago. By comparison, nanoelectronic devices employing ferroelectric domain walls often have slower domain wall speeds, but may exploit their smaller size as well as their different functional properties. These include domain wall conductivity (metallic or even superconducting in bulk insulating or semiconducting oxides) and the fact that domain walls can be ferromagnetic while the surrounding domains are not.