Sample records for wall surface meshes

  1. Bayesian segmentation of atrium wall using globally-optimal graph cuts on 3D meshes.

    PubMed

    Veni, Gopalkrishna; Fu, Zhisong; Awate, Suyash P; Whitaker, Ross T

    2013-01-01

    Efficient segmentation of the left atrium (LA) wall from delayed enhancement MRI is challenging due to inconsistent contrast, combined with noise, and high variation in atrial shape and size. We present a surface-detection method that is capable of extracting the atrial wall by computing an optimal a-posteriori estimate. This estimation is done on a set of nested meshes, constructed from an ensemble of segmented training images, and graph cuts on an associated multi-column, proper-ordered graph. The graph/mesh is a part of a template/model that has an associated set of learned intensity features. When this mesh is overlaid onto a test image, it produces a set of costs which lead to an optimal segmentation. The 3D mesh has an associated weighted, directed multi-column graph with edges that encode smoothness and inter-surface penalties. Unlike previous graph-cut methods that impose hard constraints on the surface properties, the proposed method follows from a Bayesian formulation resulting in soft penalties on spatial variation of the cuts through the mesh. The novelty of this method also lies in the construction of proper-ordered graphs on complex shapes for choosing among distinct classes of base shapes for automatic LA segmentation. We evaluate the proposed segmentation framework on simulated and clinical cardiac MRI.

  2. Sirolimus-coated, poly(L-lactic acid)-modified polypropylene mesh with minimal intra-peritoneal adhesion formation in a rat model.

    PubMed

    Lu, S; Hu, W; Zhang, Z; Ji, Z; Zhang, T

    2018-05-18

    This study evaluated the manufacturing method and anti-adhesion properties of a new composite mesh in the rat model, which was made from sirolimus (SRL) grafts on a poly(L-lactic acid) (PLLA)-modified polypropylene (PP) hernia mesh. PLLA was first grafted onto argon-plasma-treated native PP mesh through catalysis of stannous chloride. SRL was grafted onto the surface of PP-PLLA meshes using catalysis of 1-(3-dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride (EDC) and 4-dimethylaminopyridine (DMAP) in a CH 2 Cl 2 solvent. Sprague-Dawley female rats received either SRL-coated meshes, PP-PLLA meshes, or native PP meshes to repair abdominal wall defects. At different intervals, rats were euthanized by a lethal dose of chloral hydrate and adhesion area and tenacity were evaluated. Sections of the mesh with adjacent tissues were assessed histologically. Attenuated total reflection Fourier transformed infrared (ATR-FTIR) spectroscopy indicated the existence of a C=O group absorption peak (1724.1 cm -1 ), and scanning electron microscope morphological analysis indicated that the surface of the PP mesh was covered with SRL. Compared to the native PP meshes and PP-PLLA meshes, SRL-coated meshes demonstrated the greatest ability to decrease the formation of adhesions (P < 0.05) and inflammation. The SRL-coated composite mesh showed minimal formation of intra-abdominal adhesions in a rat model of abdominal wall defect repair.

  3. An implementation of a chemical and thermal nonequilibrium flow solver on unstructured meshes and application to blunt bodies

    NASA Technical Reports Server (NTRS)

    Prabhu, Ramadas K.

    1994-01-01

    This paper presents a nonequilibrium flow solver, implementation of the algorithm on unstructured meshes, and application to hypersonic flow past blunt bodies. Air is modeled as a mixture of five chemical species, namely O2, N2, O, NO, and N, having two temperatures namely translational and vibrational. The solution algorithm is a cell centered, point implicit upwind scheme that employs Roe's flux difference splitting technique. Implementation of this algorithm on unstructured meshes is described. The computer code is applied to solve Mach 15 flow with and without a Type IV shock interference on a cylindrical body of 2.5mm radius representing a cowl lip. Adaptively generated meshes are employed, and the meshes are refined several times until the solution exhibits detailed flow features and surface pressure and heat flux distributions. Effects of a catalytic wall on surface heat flux distribution are studied. For the Mach 15 Type IV shock interference flow, present results showed a peak heat flux of 544 MW/m2 for a fully catalytic wall and 431 MW/m(exp 2) for a noncatalytic wall. Some of the results are compared with available computational data.

  4. An automatic generation of non-uniform mesh for CFD analyses of image-based multiscale human airway models

    NASA Astrophysics Data System (ADS)

    Miyawaki, Shinjiro; Tawhai, Merryn H.; Hoffman, Eric A.; Lin, Ching-Long

    2014-11-01

    The authors have developed a method to automatically generate non-uniform CFD mesh for image-based human airway models. The sizes of generated tetrahedral elements vary in both radial and longitudinal directions to account for boundary layer and multiscale nature of pulmonary airflow. The proposed method takes advantage of our previously developed centerline-based geometry reconstruction method. In order to generate the mesh branch by branch in parallel, we used the open-source programs Gmsh and TetGen for surface and volume meshes, respectively. Both programs can specify element sizes by means of background mesh. The size of an arbitrary element in the domain is a function of wall distance, element size on the wall, and element size at the center of airway lumen. The element sizes on the wall are computed based on local flow rate and airway diameter. The total number of elements in the non-uniform mesh (10 M) was about half of that in the uniform mesh, although the computational time for the non-uniform mesh was about twice longer (170 min). The proposed method generates CFD meshes with fine elements near the wall and smooth variation of element size in longitudinal direction, which are required, e.g., for simulations with high flow rate. NIH Grants R01-HL094315, U01-HL114494, and S10-RR022421. Computer time provided by XSEDE.

  5. DNS and modeling of the interaction between turbulent premixed flames and walls

    NASA Technical Reports Server (NTRS)

    Poinsot, T. J.; Haworth, D. C.

    1992-01-01

    The interaction between turbulent premixed flames and walls is studied using a two-dimensional full Navier-Stokes solver with simple chemistry. The effects of wall distance on the local and global flame structure are investigated. Quenching distances and maximum wall heat fluxes during quenching are computed in laminar cases and are found to be comparable to experimental and analytical results. For turbulent cases, it is shown that quenching distances and maximum heat fluxes remain of the same order as for laminar flames. Based on simulation results, a 'law-of-the-wall' model is derived to describe the interaction between a turbulent premixed flame and a wall. This model is constructed to provide reasonable behavior of flame surface density near a wall under the assumption that flame-wall interaction takes place at scales smaller than the computational mesh. It can be implemented in conjunction with any of several recent flamelet models based on a modeled surface density equation, with no additional constraints on mesh size or time step.

  6. Navier-Stokes Computations With One-Equation Turbulence Model for Flows Along Concave Wall Surfaces

    NASA Technical Reports Server (NTRS)

    Wang, Chi R.

    2005-01-01

    This report presents the use of a time-marching three-dimensional compressible Navier-Stokes equation numerical solver with a one-equation turbulence model to simulate the flow fields developed along concave wall surfaces without and with a downstream extension flat wall surface. The 3-D Navier- Stokes numerical solver came from the NASA Glenn-HT code. The one-equation turbulence model was derived from the Spalart and Allmaras model. The computational approach was first calibrated with the computations of the velocity and Reynolds shear stress profiles of a steady flat plate boundary layer flow. The computational approach was then used to simulate developing boundary layer flows along concave wall surfaces without and with a downstream extension wall. The author investigated the computational results of surface friction factors, near surface velocity components, near wall temperatures, and a turbulent shear stress component in terms of turbulence modeling, computational mesh configurations, inlet turbulence level, and time iteration step. The computational results were compared with existing measurements of skin friction factors, velocity components, and shear stresses of the developing boundary layer flows. With a fine computational mesh and a one-equation model, the computational approach could predict accurately the skin friction factors, near surface velocity and temperature, and shear stress within the flows. The computed velocity components and shear stresses also showed the vortices effect on the velocity variations over a concave wall. The computed eddy viscosities at the near wall locations were also compared with the results from a two equation turbulence modeling technique. The inlet turbulence length scale was found to have little effect on the eddy viscosities at locations near the concave wall surface. The eddy viscosities, from the one-equation and two-equation modeling, were comparable at most stream-wise stations. The present one-equation turbulence model is an effective approach for turbulence modeling in the near solid wall surface region of flow over a concave wall.

  7. Combined in vivo and ex vivo analysis of mesh mechanics in a porcine hernia model.

    PubMed

    Kahan, Lindsey G; Lake, Spencer P; McAllister, Jared M; Tan, Wen Hui; Yu, Jennifer; Thompson, Dominic; Brunt, L Michael; Blatnik, Jeffrey A

    2018-02-01

    Hernia meshes exhibit variability in mechanical properties, and their mechanical match to tissue has not been comprehensively studied. We used an innovative imaging model of in vivo strain tracking and ex vivo mechanical analysis to assess effects of mesh properties on repaired abdominal walls in a porcine model. We hypothesized that meshes with dissimilar mechanical properties compared to native tissue would alter abdominal wall mechanics more than better-matched meshes. Seven mini-pigs underwent ventral hernia creation and subsequent open repair with one of two heavyweight polypropylene meshes. Following mesh implantation with attached radio-opaque beads, fluoroscopic images were taken at insufflation pressures from 5 to 30 mmHg on postoperative days 0, 7, and 28. At 28 days, animals were euthanized and ex vivo mechanical testing performed on full-thickness samples across repaired abdominal walls. Testing was conducted on 13 mini-pig controls, and on meshes separately. Stiffness and anisotropy (the ratio of stiffness in the transverse versus craniocaudal directions) were assessed. 3D reconstructions of repaired abdominal walls showed stretch patterns. As pressure increased, both meshes expanded, with no differences between groups. Over time, meshes contracted 17.65% (Mesh A) and 0.12% (Mesh B; p = 0.06). Mesh mechanics showed that Mesh A deviated from anisotropic native tissue more than Mesh B. Compared to native tissue, Mesh A was stiffer both transversely and craniocaudally. Explanted repaired abdominal walls of both treatment groups were stiffer than native tissue. Repaired tissue became less anisotropic over time, as mesh properties prevailed over native abdominal wall properties. This technique assessed 3D stretch at the mesh level in vivo in a porcine model. While the abdominal wall expanded, mesh-ingrown areas contracted, potentially indicating stresses at mesh edges. Ex vivo mechanics demonstrate that repaired tissue adopts mesh properties, suggesting that a better-matched mesh could reduce changes to abdominal wall mechanics.

  8. Non-cross-linked porcine acellular dermal matrices for abdominal wall reconstruction.

    PubMed

    Burns, Nadja K; Jaffari, Mona V; Rios, Carmen N; Mathur, Anshu B; Butler, Charles E

    2010-01-01

    Non-cross-linked porcine acellular dermal matrices have been used clinically for abdominal wall repair; however, their biologic and mechanical properties and propensity to form visceral adhesions have not been studied. The authors hypothesized that their use would result in fewer, weaker visceral adhesions than polypropylene mesh when used to repair ventral hernias and form a strong interface with the surrounding musculofascia. Thirty-four guinea pigs underwent inlay repair of surgically created ventral hernias using polypropylene mesh, porcine acellular dermal matrix, or a composite of the two. The animals were killed at 4 weeks, and the adhesion tenacity grade and surface area of the repair site involved by adhesions were measured. Sections of the repair sites, including the implant-musculofascia interface, underwent histologic analysis and uniaxial mechanical testing. The incidence of bowel adhesions to the repair site was significantly lower with the dermal matrix (8 percent, p < 0.01) and the matrix/mesh combination (0 percent, p < 0.001) than with polypropylene mesh alone (70 percent). The repairs made with the matrix or the matrix/mesh combination, compared with the polypropylene mesh repairs, had significantly lower mean adhesion surface areas [12.8 percent (p < 0.001), 9.2 percent (p < 0.001), and 79.9 percent] and grades [0.6 (p < 0.001), 0.6 (p < 0.001), and 2.9]. The dermal matrix underwent robust cellular and vascular infiltration. The ultimate tensile strength at the implant-musculofascia interface was similar in all groups. Porcine acellular dermal matrix becomes incorporated into the host tissue and causes fewer adhesions to repair sites than does polypropylene mesh, with similar implant-musculofascia interface strength. It also inhibits adhesions to adjacent dermal matrix in the combination repairs. It has distinct advantages over polypropylene mesh for complex abdominal wall repairs, particularly when material placement directly over bowel is unavoidable.

  9. [The use of a prolene double mesh for orbital wall reconstruction].

    PubMed

    Junceda-Moreno, J; Suárez-Suárez, E; Dos-Santos-Bernardo, V

    2005-08-01

    Patient with a recurrent carcinoma of the nasal fossae affecting the internal orbital wall. The intraorbital content was not affected. The orbital wall was reconstructed with a prolene double mesh anchored to the periosteum. Prolene mesh as a substitute of the orbital wall. Good stability and isolation of the intraorbital structures were observed. Ocular motility was completely normal after surgery without prolene mesh displacements. The prolene double mesh is a good surgical option to replace missing bone in the reconstruction of the internal orbital wall.

  10. Bioprosthetic Mesh in Abdominal Wall Reconstruction

    PubMed Central

    Baumann, Donald P.; Butler, Charles E.

    2012-01-01

    Mesh materials have undergone a considerable evolution over the last several decades. There has been enhancement of biomechanical properties, improvement in manufacturing processes, and development of antiadhesive laminate synthetic meshes. The evolution of bioprosthetic mesh materials has markedly changed our indications and methods for complex abdominal wall reconstruction. The authors review the optimal properties of bioprosthetic mesh materials, their evolution over time, and their indications for use. The techniques to optimize outcomes are described using bioprosthetic mesh for complex abdominal wall reconstruction. Bioprosthetic mesh materials clearly have certain advantages over other implantable mesh materials in select indications. Appropriate patient selection and surgical technique are critical to the successful use of bioprosthetic materials for abdominal wall repair. PMID:23372454

  11. Mesh abdominal wall hernia surgery is safe and effective-the harm New Zealand media has done.

    PubMed

    Kelly, Steven

    2017-10-06

    Patients in New Zealand have now developed a fear of mesh abdominal wall hernia repair due to inaccurate media reporting. This article outlines the extensive literature that confirms abdominal wall mesh hernia repair is safe and effective. The worsening confidence in the transvaginal mesh prolapse repair should not adversely affect the good results of mesh abdominal wall hernia repair. New Zealand general surgeons are well trained in providing modern hernia surgery.

  12. Mechanical behaviour of synthetic surgical meshes: finite element simulation of the herniated abdominal wall.

    PubMed

    Hernández-Gascón, B; Peña, E; Melero, H; Pascual, G; Doblaré, M; Ginebra, M P; Bellón, J M; Calvo, B

    2011-11-01

    The material properties of meshes used in hernia surgery contribute to the overall mechanical behaviour of the repaired abdominal wall. The mechanical response of a surgical mesh has to be defined since the haphazard orientation of an anisotropic mesh can lead to inconsistent surgical outcomes. This study was designed to characterize the mechanical behaviour of three surgical meshes (Surgipro®, Optilene® and Infinit®) and to describe a mechanical constitutive law that accurately reproduces the experimental results. Finally, through finite element simulation, the behaviour of the abdominal wall was modelled before and after surgical mesh implant. Uniaxial loading of mesh samples in two perpendicular directions revealed the isotropic response of Surgipro® and the anisotropic behaviour of Optilene® and Infinit®. A phenomenological constitutive law was used to reproduce the measured experimental curves. To analyze the mechanical effect of the meshes once implanted in the abdomen, finite element simulation of the healthy and partially herniated repaired rabbit abdominal wall served to reproduce wall behaviour before and after mesh implant. In all cases, maximal displacements were lower and maximal principal stresses higher in the implanted abdomen than the intact wall model. Despite the fact that no mesh showed a behaviour that perfectly matched that of abdominal muscle, the Infinit® mesh was able to best comply with the biomechanics of the abdominal wall. Copyright © 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  13. Progress Towards a Cartesian Cut-Cell Method for Viscous Compressible Flow

    NASA Technical Reports Server (NTRS)

    Berger, Marsha; Aftosmis, Michael J.

    2012-01-01

    We present preliminary development of an approach for simulating high Reynolds number steady compressible flow in two space dimensions using a Cartesian cut-cell finite volume method. We consider both laminar and turbulent flow with both low and high cell Reynolds numbers near the wall. The approach solves the full Navier-Stokes equations in all cells, and uses a wall model to address the resolution requirements near boundaries and to mitigate mesh irregularities in cut cells. We present a quadratic wall model for low cell Reynolds numbers. At high cell Reynolds numbers, the quadratic is replaced with a newly developed analytic wall model stemming from solution of a limiting form of the Spalart-Allmaras turbulence model which features a forward evaluation for flow velocity and exactly matches characteristics of the SA turbulence model in the field. We develop multigrid operators which attain convergence rates similar to inviscid multigrid. Investigations focus on preliminary verification and validation of the method. Flows over flat plates and compressible airfoils show good agreement with both theoretical results and experimental data. Mesh convergence studies on sub- and transonic airfoil flows show convergence of surface pressures with wall spacings as large as approx.0.1% chord. With the current analytic wall model, one or two additional refinements near the wall are required to obtain mesh converged values of skin friction.

  14. Three-dimensional analysis of implanted magnetic-resonance-visible meshes.

    PubMed

    Sindhwani, Nikhil; Feola, Andrew; De Keyzer, Frederik; Claus, Filip; Callewaert, Geertje; Urbankova, Iva; Ourselin, Sebastien; D'hooge, Jan; Deprest, Jan

    2015-10-01

    Our primary objective was to develop relevant algorithms for quantification of mesh position and 3D shape in magnetic resonance (MR) images. In this proof-of-principle study, one patient with severe anterior vaginal wall prolapse was implanted with an MR-visible mesh. High-resolution MR images of the pelvis were acquired 6 weeks and 8 months postsurgery. 3D models were created using semiautomatic segmentation techniques. Conformational changes were recorded quantitatively using part-comparison analysis. An ellipticity measure is proposed to record longitudinal conformational changes in the mesh arms. The surface that is the effective reinforcement provided by the mesh is calculated using a novel methodology. The area of this surface is the effective support area (ESA). MR-visible mesh was clearly outlined in the images, which allowed us to longitudinally quantify mesh configuration between 6 weeks and 8 months after implantation. No significant changes were found in mesh position, effective support area, conformation of the mesh's main body, and arm length during the period of observation. Ellipticity profiles show longitudinal conformational changes in posterior arms. This paper proposes novel methodologies for a systematic 3D assessment of the position and morphology of MR-visible meshes. A novel semiautomatic tool was developed to calculate the effective area of support provided by the mesh, a potentially clinically important parameter.

  15. Toward Immersed Boundary Simulation of High Reynolds Number Flows

    NASA Technical Reports Server (NTRS)

    Kalitzin, Georgi; Iaccarino, Gianluca

    2003-01-01

    In the immersed boundary (IB) method, the surface of an object is reconstructed with forcing terms in the underlying flow field equations. The surface may split a computational cell removing the constraint of the near wall gridlines to be aligned with the surface. This feature greatly simplifies the grid generation process which is cumbersome and expensive in particular for structured grids and complex geometries. The IB method is ideally suited for Cartesian flow solvers. The flow equations written in Cartesian coordinates appear in a very simple form and several numerical algorithms can be used for an efficient solution of the equations. In addition, the accuracy of numerical algorithms is dependent on the underlying grid and it usually deteriorates when the grid deviates from a Cartesian mesh. The challenge for the IB method lies in the representation of the wall boundaries and in providing an adequate near wall flow field resolution. The issue of enforcing no-slip boundary conditions at the immersed surface has been addressed by several authors by imposing a local reconstruction of the solution. Initial work by Verzicco et al. was based on a simple linear, one-dimensional operator and this approach proved to be accurate for boundaries largely aligned with the grid lines. Majumdar et al. used various multidimensional and high order polynomial interpolations schemes. These high order schemes, however, are keen to introduce wiggles and spurious extrema. Iaccarino & Verzicco and Kalitzin & Iaccarino proposed a tri-linear reconstruction for the velocity components and the turbulent scalars. A modified implementation that has proven to be more robust is reported in this paper. The issue of adequate near wall resolution in a Cartesian framework can initially be addressed by using a non-uniform mesh which is stretched near the surface. In this paper, we investigate an unstructured approach for local grid refinement that utilizes Cartesian mesh features. The computation of high Reynolds number wall bounded flows is particularly challenging as it requires the consideration of thin turbulent boundary layers, i.e. near wall regions with large gradients of the flow field variables. For such flows, the representation of the wall boundary has a large impact on the accuracy of the computation. It is also critical for the robustness and convergence of the flow solver.

  16. Primary fascial closure with biologic mesh reinforcement results in lesser complication and recurrence rates than bridged biologic mesh repair for abdominal wall reconstruction: A propensity score analysis.

    PubMed

    Giordano, Salvatore; Garvey, Patrick B; Baumann, Donald P; Liu, Jun; Butler, Charles E

    2017-02-01

    Previous studies suggest that bridged mesh repair for abdominal wall reconstruction may result in worse outcomes than mesh-reinforced, primary fascial closure, particularly when acellular dermal matrix is used. We compared our outcomes of bridged versus reinforced repair using ADM in abdominal wall reconstruction procedures. This retrospective study included 535 consecutive patients at our cancer center who underwent abdominal wall reconstruction either for an incisional hernia or for abdominal wall defects left after excision of malignancies involving the abdominal wall with underlay mesh. A total of 484 (90%) patients underwent mesh-reinforced abdominal wall reconstruction and 51 (10%) underwent bridged repair abdominal wall reconstruction. Acellular dermal matrix was used, respectively, in 98% of bridged and 96% of reinforced repairs. We compared outcomes between these 2 groups using propensity score analysis for risk-adjustment in multivariate analysis and for 1-to-1 matching. Bridged repairs had a greater hernia recurrence rate (33.3% vs 6.2%, P < .001), a greater overall complication rate (59% vs 30%, P = .001), and worse freedom from hernia recurrence (log-rank P <.001) than reinforced repairs. Bridged repairs also had a greater rate of wound dehiscence (26% vs 14%, P = .034) and mesh exposure (10% vs 1%, P = .003) than mesh-reinforced abdominal wall reconstruction. When the treatment method was adjusted for propensity score in the propensity-score-matched pairs (n = 100), we found that the rates of hernia recurrence (32% vs 6%, P = .002), overall complications (32% vs 6%, P = .002), and freedom from hernia recurrence (68% vs 32%, P = .001) rates were worse after bridged repair. We did not observe differences in wound healing and mesh complications between the 2 groups. In our population of primarily cancer patients at MD Anderson Cancer Center bridged repair for abdominal wall reconstruction is associated with worse outcomes than mesh-reinforced abdominal wall reconstruction. Particularly when employing acellular dermal matrix, reinforced repairs should be used for abdominal wall reconstruction whenever possible. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Automated hexahedral mesh generation from biomedical image data: applications in limb prosthetics.

    PubMed

    Zachariah, S G; Sanders, J E; Turkiyyah, G M

    1996-06-01

    A general method to generate hexahedral meshes for finite element analysis of residual limbs and similar biomedical geometries is presented. The method utilizes skeleton-based subdivision of cross-sectional domains to produce simple subdomains in which structured meshes are easily generated. Application to a below-knee residual limb and external prosthetic socket is described. The residual limb was modeled as consisting of bones, soft tissue, and skin. The prosthetic socket model comprised a socket wall with an inner liner. The geometries of these structures were defined using axial cross-sectional contour data from X-ray computed tomography, optical scanning, and mechanical surface digitization. A tubular surface representation, using B-splines to define the directrix and generator, is shown to be convenient for definition of the structure geometries. Conversion of cross-sectional data to the compact tubular surface representation is direct, and the analytical representation simplifies geometric querying and numerical optimization within the mesh generation algorithms. The element meshes remain geometrically accurate since boundary nodes are constrained to lie on the tubular surfaces. Several element meshes of increasing mesh density were generated for two residual limbs and prosthetic sockets. Convergence testing demonstrated that approximately 19 elements are required along a circumference of the residual limb surface for a simple linear elastic model. A model with the fibula absent compared with the same geometry with the fibula present showed differences suggesting higher distal stresses in the absence of the fibula. Automated hexahedral mesh generation algorithms for sliced data represent an advancement in prosthetic stress analysis since they allow rapid modeling of any given residual limb and optimization of mesh parameters.

  18. A study of nucleate boiling and critical heat flux with EHD enhancement

    NASA Astrophysics Data System (ADS)

    Hristov, Y.; Zhao, D.; Kenning, D. B. R.; Sefiane, K.; Karayiannis, T. G.

    2009-05-01

    The paper describes results from an experimental and theoretical study of the effect of an electric field on nucleate boiling and the critical heat flux (CHF) in pool boiling of R123 at atmospheric pressure on a horizontal wall with a smooth surface. Two designs of electrode (parallel rods and wire mesh) were used. The experimental data exhibit some differences from the data obtained by other researchers in similar experiments on a wall with a different surface finish and with a slightly different design of wire mesh electrode. The hydrodynamic model for EHD enhancement of CHF cannot reconcile the differences. A theoretical model has been developed for the growth of a single vapour bubble on a superheated wall in an electric field, leading to a numerical simulation based on the level-set method. The model includes matching of sub-models for the micro- and macro-regions, conduction in the wall, distortion of the electric field by the bubble, the temperature dependence of electrical properties and free-charge generation. In the present form of the model, some of these effects are realised in an approximate form. The capability to investigate dry-spot formation and wall temperature changes that might lead to CHF has been demonstrated.

  19. Chromatography resin support

    DOEpatents

    Dobos, James G.

    2002-01-01

    An apparatus and method of using an improved chromatography resin support is disclosed. The chromatography support platform is provided by a stainless steel hollow cylinder adapted for being inserted into a chromatography column. An exterior wall of the stainless steel cylinder defines a groove for carrying therein an "O"-ring. The upper surface of the stainless steel column is covered by a fine stainless steel mesh welded to the edges of the stainless steel cylinder. When placed upon a receiving ledge defined within a chromatography column, the "O"-ring provides a fluid tight seal with the inner edge wall of the chromatography cylinder. The stainless steel mesh supports the chromatography matrix and provides a back flushable support which is economical and simple to construct.

  20. MRI Evaluation of an Elastic TPU Mesh under Pneumoperitoneum in IPOM Position in a Porcine Model.

    PubMed

    Lambertz, A; van den Hil, L C L; Ciritsis, A; Eickhoff, R; Kraemer, N A; Bouvy, N D; Müllen, A; Klinge, U; Neumann, U P; Klink, C D

    2018-06-01

    The frequency of laparoscopic approaches increased in hernia surgery over the past years. After mesh placement in IPOM position, the real extent of the meshes configurational changes after termination of pneumoperitoneum is still largely unknown. To prevent a later mesh folding it might be useful to place the mesh while it is kept under tension. Conventionally used meshes may lose their Effective Porosity under these conditions due to poor elastic properties. The aim of this study was to evaluate a newly developed elastic thermoplastic polyurethane (TPU) containing mesh that retains its Effective Porosity under mechanical strain in IPOM position in a porcine model. It was visualized under pneumoperitoneum using MRI in comparison to polyvinylidenefluoride (PVDF) meshes with similar structure. In each of ten minipigs, a mesh (TPU containing or native PVDF, 10 × 20 cm) was randomly placed in IPOM position at the center of the abdominal wall. After 8 weeks, six pigs underwent MRI evaluation with and without pneumoperitoneum to assess the visibility and elasticity of the mesh. Finally, pigs were euthanized and abdominal walls were explanted for histological and immunohistochemical assessment. The degree of adhesion formation was documented. Laparoscopic implantation of elastic TPU meshes in IPOM position was feasible and safe in a minipig model. Mesh position could be precisely visualized and assessed with and without pneumoperitoneum using MRI after 8 weeks. Elastic TPU meshes showed a significantly higher surface increase under pneumoperitoneum in comparison to PVDF. Immunohistochemically, the amount of CD45-positive cells was significantly lower and the Collagen I/III ratio was significantly higher in TPU meshes after 8 weeks. There were no differences regarding adhesion formation between study groups. The TPU mesh preserves its elastic properties in IPOM position in a porcine model after 8 weeks. Immunohistochemistry indicates superior biocompatibility regarding CD45-positive cells and Collagen I/III ratio in comparison to PVDF meshes with a similar structure.

  1. What is the evidence for the use of biologic or biosynthetic meshes in abdominal wall reconstruction?

    PubMed

    Köckerling, F; Alam, N N; Antoniou, S A; Daniels, I R; Famiglietti, F; Fortelny, R H; Heiss, M M; Kallinowski, F; Kyle-Leinhase, I; Mayer, F; Miserez, M; Montgomery, A; Morales-Conde, S; Muysoms, F; Narang, S K; Petter-Puchner, A; Reinpold, W; Scheuerlein, H; Smietanski, M; Stechemesser, B; Strey, C; Woeste, G; Smart, N J

    2018-04-01

    Although many surgeons have adopted the use of biologic and biosynthetic meshes in complex abdominal wall hernia repair, others have questioned the use of these products. Criticism is addressed in several review articles on the poor standard of studies reporting on the use of biologic meshes for different abdominal wall repairs. The aim of this consensus review is to conduct an evidence-based analysis of the efficacy of biologic and biosynthetic meshes in predefined clinical situations. A European working group, "BioMesh Study Group", composed of invited surgeons with a special interest in surgical meshes, formulated key questions, and forwarded them for processing in subgroups. In January 2016, a workshop was held in Berlin where the findings were presented, discussed, and voted on for consensus. Findings were set out in writing by the subgroups followed by consensus being reached. For the review, 114 studies and background analyses were used. The cumulative data regarding biologic mesh under contaminated conditions do not support the claim that it is better than synthetic mesh. Biologic mesh use should be avoided when bridging is needed. In inguinal hernia repair biologic and biosynthetic meshes do not have a clear advantage over the synthetic meshes. For prevention of incisional or parastomal hernias, there is no evidence to support the use of biologic/biosynthetic meshes. In complex abdominal wall hernia repairs (incarcerated hernia, parastomal hernia, infected mesh, open abdomen, enterocutaneous fistula, and component separation technique), biologic and biosynthetic meshes do not provide a superior alternative to synthetic meshes. The routine use of biologic and biosynthetic meshes cannot be recommended.

  2. The Relationship Between Surface Curvature and Abdominal Aortic Aneurysm Wall Stress.

    PubMed

    de Galarreta, Sergio Ruiz; Cazón, Aitor; Antón, Raúl; Finol, Ender A

    2017-08-01

    The maximum diameter (MD) criterion is the most important factor when predicting risk of rupture of abdominal aortic aneurysms (AAAs). An elevated wall stress has also been linked to a high risk of aneurysm rupture, yet is an uncommon clinical practice to compute AAA wall stress. The purpose of this study is to assess whether other characteristics of the AAA geometry are statistically correlated with wall stress. Using in-house segmentation and meshing algorithms, 30 patient-specific AAA models were generated for finite element analysis (FEA). These models were subsequently used to estimate wall stress and maximum diameter and to evaluate the spatial distributions of wall thickness, cross-sectional diameter, mean curvature, and Gaussian curvature. Data analysis consisted of statistical correlations of the aforementioned geometry metrics with wall stress for the 30 AAA inner and outer wall surfaces. In addition, a linear regression analysis was performed with all the AAA wall surfaces to quantify the relationship of the geometric indices with wall stress. These analyses indicated that while all the geometry metrics have statistically significant correlations with wall stress, the local mean curvature (LMC) exhibits the highest average Pearson's correlation coefficient for both inner and outer wall surfaces. The linear regression analysis revealed coefficients of determination for the outer and inner wall surfaces of 0.712 and 0.516, respectively, with LMC having the largest effect on the linear regression equation with wall stress. This work underscores the importance of evaluating AAA mean wall curvature as a potential surrogate for wall stress.

  3. Transfer and alignment of random single-walled carbon nanotube films by contact printing.

    PubMed

    Liu, Huaping; Takagi, Daisuke; Chiashi, Shohei; Homma, Yoshikazu

    2010-02-23

    We present a simple method to transfer large-area random single-walled carbon nanotube (SWCNT) films grown on SiO(2) substrates onto another surface through a simple contact printing process. The transferred random SWCNT films can be assembled into highly ordered, dense regular arrays with high uniformity and reproducibility by sliding the growth substrate during the transfer process. The position of the transferred SWCNT film can be controlled by predefined patterns on the receiver substrates. The process is compatible with a variety of substrates, and even metal meshes for transmission electron microscopy (TEM) can be used as receiver substrates. Thus, suspended web-like SWCNT networks and aligned SWCNT arrays can be formed over the grids of TEM meshes, so that the structures of the transferred SWCNTs can be directly observed by TEM. This simple technique can be used to controllably transfer SWCNTs for property studies, for the fabrication of devices, or even as support films for TEM meshes.

  4. Evaluation of optical data gained by ARAMIS-measurement of abdominal wall movements for an anisotropic pattern design of stress-adapted hernia meshes produced by embroidery technology

    NASA Astrophysics Data System (ADS)

    Breier, A.; Bittrich, L.; Hahn, J.; Spickenheuer, A.

    2017-10-01

    For the sustainable repair of abdominal wall hernia the application of hernia meshes is required. One reason for the relapse of hernia after surgery is seen in an inadequate adaption of the mechanical properties of the mesh to the movements of the abdominal wall. Differences in the stiffness of the mesh and the abdominal tissue cause tension, friction and stress resulting in a deficient tissue response and subsequently in a recurrence of a hernia, preferentially in the marginal area of the mesh. Embroidery technology enables a targeted influence on the mechanical properties of the generated textile structure by a directed thread deposition. Textile parameters like stitch density, alignment and angle can be changed easily and locally in the embroidery pattern to generate a space-resolved mesh with mechanical properties adapted to the requirement of the surrounding tissue. To determine those requirements the movements of the abdominal wall and the resulting distortions need to be known. This study was conducted to gain optical data of the abdominal wall movements by non-invasive ARAMIS-measurement on 39 test persons to estimate direction and value of the major strains.

  5. Sensitivity analysis on the effective stiffness properties of 3-D orthotropic honeycomb cores

    NASA Astrophysics Data System (ADS)

    Karakoç, Alp

    2018-01-01

    The present study investigates the influences of representative volume element RVE mesh and material parameters, here cell wall elastic moduli, on the effective stiffness properties of three dimensional orthotropic honeycomb cores through strain driven computational homogenization in the finite element framework. For this purpose, case studies were carried out, for which hexagonal cellular RVEs were generated, meshed with eight node linear brick finite elements of varying numbers. Periodic boundary conditions were then implemented on the RVE boundaries by using one-to-one nodal match for the corresponding corners, edges and surfaces for the imposed macroscopic strains. As a novelty, orthotropic material properties were assigned for each cell wall by means of the transformation matrices following the cell wall orientations. Thereafter, simulations were conducted and volume averaged macroscopic stresses were obtained. Eventually, effective stiffness properties were obtained, through which RVE sensitivity analysis was carried out. The investigations indicate that there is a strong relation between number of finite elements and most of the effective stiffness parameters. In addition to this, cell wall elastic moduli also play critical role on the effective properties of the investigated materials.

  6. Investigation into the optimal prosthetic material for wound healing of abdominal wall defects

    PubMed Central

    Akcakaya, Adem; Aydogdu, Ibrahim; Citgez, Bulent

    2018-01-01

    The purpose of this experimental study is to investigate and compare the effects of prosthetic materials used for wound healing of abdominal wall hernias. A total of 60 rats were divided into five equal groups: Group I, control subjected to laparotomy; group II, abdominal wall defect 3×2 cm+polypropylene (PP) mesh; group III, abdominal wall defect 3×2 cm+PP mesh+hyaluronate and carboxymethylcellulose (H-CMC; Seprafilm®); group IV, abdominal wall defect 3×2 cm+polytetrafluoroethylene (PTFE; Composix™); and group V, abdominal wall defect 3×2 cm+polyethylene terephthalate (PET; Dacron®). A total of 14 days after the surgery, rats were sacrificed and the meshes with the surrounding tissue were extracted in block. The breaking strength of the mesh from the fascia was recorded. The healing tissue was examined with the index of histopathology and the hydroxyproline value was analyzed using the Switzer method. Both the breaking strength and histopathological index of the wound healing were significantly improved in groups II and III compared with that in groups IV and V (P<0.001). Hydroxyproline values were the highest in group I (P<0.001). There was also a statistically significant difference between groups II and IV, and group V and the other groups (P<0.001). The present findings demonstrated that PP mesh and PP mesh+H-CMC had a superior breaking strength and improved histopathologic indices compared with PTFE and PET. Furthermore, hydroxyproline values were the lowest in the PET group. In conclusion, wound healing was improved in the PP mesh group and the PP mesh+H-CMC group compared with the PTFE and PET groups according to the present study parameters. PMID:29399133

  7. Capturing strain localization behind a geosynthetic-reinforced soil wall

    NASA Astrophysics Data System (ADS)

    Lai, Timothy Y.; Borja, Ronaldo I.; Duvernay, Blaise G.; Meehan, Richard L.

    2003-04-01

    This paper presents the results of finite element (FE) analyses of shear strain localization that occurred in cohesionless soils supported by a geosynthetic-reinforced retaining wall. The innovative aspects of the analyses include capturing of the localized deformation and the accompanying collapse mechanism using a recently developed embedded strong discontinuity model. The case study analysed, reported in previous publications, consists of a 3.5-m tall, full-scale reinforced wall model deforming in plane strain and loaded by surcharge at the surface to failure. Results of the analysis suggest strain localization developing from the toe of the wall and propagating upward to the ground surface, forming a curved failure surface. This is in agreement with a well-documented failure mechanism experienced by the physical wall model showing internal failure surfaces developing behind the wall as a result of the surface loading. Important features of the analyses include mesh sensitivity studies and a comparison of the localization properties predicted by different pre-localization constitutive models, including a family of three-invariant elastoplastic constitutive models appropriate for frictional/dilatant materials. Results of the analysis demonstrate the potential of the enhanced FE method for capturing a collapse mechanism characterized by the presence of a failure, or slip, surface through earthen materials.

  8. A family of position- and orientation-independent embedded boundary methods for viscous flow and fluid-structure interaction problems

    NASA Astrophysics Data System (ADS)

    Huang, Daniel Z.; De Santis, Dante; Farhat, Charbel

    2018-07-01

    The Finite Volume method with Exact two-material Riemann Problems (FIVER) is both a computational framework for multi-material flows characterized by large density jumps, and an Embedded Boundary Method (EBM) for computational fluid dynamics and highly nonlinear Fluid-Structure Interaction (FSI) problems. This paper deals with the EBM aspect of FIVER. For FSI problems, this EBM has already demonstrated the ability to address viscous effects along wall boundaries, and large deformations and topological changes of such boundaries. However, like for most EBMs - also known as immersed boundary methods - the performance of FIVER in the vicinity of a wall boundary can be sensitive with respect to the position and orientation of this boundary relative to the embedding mesh. This is mainly due to ill-conditioning issues that arise when an embedded interface becomes too close to a node of the embedding mesh, which may lead to spurious oscillations in the computed solution gradients at the wall boundary. This paper resolves these issues by introducing an alternative definition of the active/inactive status of a mesh node that leads to the removal of all sources of potential ill-conditioning from all spatial approximations performed by FIVER in the vicinity of a fluid-structure interface. It also makes two additional contributions. The first one is a new procedure for constructing the fluid-structure half Riemann problem underlying the semi-discretization by FIVER of the convective fluxes. This procedure eliminates one extrapolation from the conventional treatment of the wall boundary conditions and replaces it by an interpolation, which improves robustness. The second contribution is a post-processing algorithm for computing quantities of interest at the wall that achieves smoothness in the computed solution and its gradients. Lessons learned from these enhancements and contributions that are triggered by the new definition of the status of a mesh node are then generalized and exploited to eliminate from the original version of the FIVER method its sensitivities with respect to both of the position and orientation of the wall boundary relative to the embedding mesh, while maintaining the original definition of the status of a mesh node. This leads to a family of second-generation FIVER methods whose performance is illustrated in this paper for several flow and FSI problems. These include a challenging flow problem over a bird wing characterized by a feather-induced surface roughness, and a complex flexible flapping wing problem for which experimental data is available.

  9. Stress adapted embroidered meshes with a graded pattern design for abdominal wall hernia repair

    NASA Astrophysics Data System (ADS)

    Hahn, J.; Bittrich, L.; Breier, A.; Spickenheuer, A.

    2017-10-01

    Abdominal wall hernias are one of the most relevant injuries of the digestive system with 25 million patients in 2013. Surgery is recommended primarily using allogenic non-absorbable wrap-knitted meshes. These meshes have in common that their stress-strain behaviour is not adapted to the anisotropic behaviour of native abdominal wall tissue. The ideal mesh should possess an adequate mechanical behaviour and a suitable porosity at the same time. An alternative fabrication method to wrap-knitting is the embroidery technology with a high flexibility in pattern design and adaption of mechanical properties. In this study, a pattern generator was created for pattern designs consisting of a base and a reinforcement pattern. The embroidered mesh structures demonstrated different structural and mechanical characteristics. Additionally, the investigation of the mechanical properties exhibited an anisotropic mechanical behaviour for the embroidered meshes. As a result, the investigated pattern generator and the embroidery technology allow the production of stress adapted mesh structures that are a promising approach for hernia reconstruction.

  10. Inlet Spillage Drag Predictions Using the AIRPLANE Code

    NASA Technical Reports Server (NTRS)

    Thomas, Scott D.; Won, Mark A.; Cliff, Susan E.

    1999-01-01

    AIRPLANE (Jameson/Baker) is a steady inviscid unstructured Euler flow solver. It has been validated on many HSR geometries. It is implemented as MESHPLANE, an unstructured mesh generator, and FLOPLANE, an iterative flow solver. The surface description from an Intergraph CAD system goes into MESHPLANE as collections of polygonal curves to generate the 3D mesh. The flow solver uses a multistage time stepping scheme with residual averaging to approach steady state, but R is not time accurate. The flow solver was ported from Cray to IBM SP2 by Wu-Sun Cheng (IBM); it could only be run on 4 CPUs at a time because of memory limitations. Meshes for the four cases had about 655,000 points in the flow field, about 3.9 million tetrahedra, about 77,500 points on the surface. The flow solver took about 23 wall seconds per iteration when using 4 CPUs. It took about eight and a half wall hours to run 1,300 iterations at a time (the queue limit is 10 hours). A revised version of FLOPLANE (Thomas) was used on up to 64 CPUs to finish up some calculations at the end. We had to turn on more communication when using more processors to eliminate noise that was contaminating the flow field; this added about 50% to the elapsed wall time per iteration when using 64 CPUs. This study involved computing lift and drag for a wing/body/nacelle configuration at Mach 0.9 and 4 degrees pitch. Four cases were considered, corresponding to four nacelle mass flow conditions.

  11. Mechanical behavior of surgical meshes for abdominal wall repair: In vivo versus biaxial characterization.

    PubMed

    Simón-Allué, R; Ortillés, A; Calvo, B

    2018-06-01

    Despite the widespread use of synthetic meshes in the surgical treatment of the hernia pathology, the election criteria of a suitable mesh for specific patient continues to be uncertain. Thus, in this work, we propose a methodology to determine in advance potential disadvantages on the use of certain meshes based on the patient-specific abdominal geometry and the mechanical features of the certain meshes. To that purpose, we have first characterized the mechanical behavior of four synthetic meshes through biaxial tests. Secondly, two of these meshes were implanted in several New Zealand rabbits with a total defect previously created on the center of the abdominal wall. After the surgical procedure, specimen were subjected to in vivo pneumoperitoneum tests to determine the immediate post-surgical response of those meshes after implanted in a healthy specimen. Experimental performance was recorded by a stereo rig with the aim of obtaining quantitative information about the pressure-displacement relation of the abdominal wall. Finally, following the procedure presented in prior works (Simón-Allué et al., 2015, 2017), a finite element model was reconstructed from the experimental measurements and tests were computationally reproduced for the healthy and herniated cases. Simulations were compared and validated with the in vivo behavior and results were given along the abdominal wall in terms of displacements, stresses and strain. Mechanical characterization of the meshes revealed Surgipro TM as the most rigid implant and Neomesh SuperSoft® as the softer, while other two meshes (Neomesh Soft®, Neopore®) remained in between. These two meshes were employed in the experimental study and resulted in similar effect in the abdominal wall cavity and both were close to the healthy case. Simulations confirmed this result while showed potential objections in the case of the other two meshes, due to high values in stresses or elongation that may led to discomfort in real tissue. The use of this methodology on human surgery may provide the surgeons with reliable and useful information to avoid certain meshes on specific-patient treatment. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. [Abdominal traumatic evisceration: reconstruction abdominal wall with biologic mesh and negative pressure therapy].

    PubMed

    Jiménez Gómez, M; Betancor Rivera, N; Lima Sánchez, J; Hernández Hernández, J R

    2016-04-10

    Abdominal traumatic evisceration as a result of high energy trauma is uncommon. Once repaired the possible internal damage, an abdominal wall defect of high complexity may exist, whose reconstruction represents a surgical challenge. Politraumatized male with important abdominal muculocutaneous avulsion and evisceration. After initial repair, the patient developed a big eventration in which we use a porcine dermis-derived mesh (Permacol TM ), a safe and effective alternative in abdominal wall repair, thanks to its seamless integration with other tissues, even when exposed. Negative pressure therapy has been used for the management of wound complications after surgical implantation of PermacolTM mesh. We describe our experience with the use of PermacolTM mesh and negative pressure therapy to aid the wound closure after skin necrosis and exposed mesh.

  13. Critical surface roughness for wall bounded flow of viscous fluids in an electric submersible pump

    NASA Astrophysics Data System (ADS)

    Deshmukh, Dhairyasheel; Siddique, Md Hamid; Kenyery, Frank; Samad, Abdus

    2017-11-01

    Surface roughness plays a vital role in the performance of an electric submersible pump (ESP). A 3-D numerical analysis has been carried out to find the roughness effect on ESP. The performance of pump for steady wall bounded turbulent flows is evaluated at different roughness values and compared with smooth surface considering a non-dimensional roughness factor K. The k- ω SST turbulence model with fine mesh at near wall region captures the rough wall effects accurately. Computational results are validated with experimental results of water (1 cP), at a design speed (3000 RPM). Maximum head is observed for a hydraulically smooth surface (K=0). When roughness factor is increased, the head decreases till critical roughness factor (K=0.1) due to frictional loss. Further increase in roughness factor (K>0.1) increases the head due to near wall turbulence. The performance of ESP is analyzed for turbulent kinetic energy and eddy viscosity at different roughness values. The wall disturbance over the rough surface affects the pressure distribution and velocity field. The roughness effect is predominant for high viscosity oil (43cP) as compared to water. Moreover, the study at off-design conditions showed that Reynolds number influences the overall roughness effect.

  14. Remodeling characteristics and collagen distribution in synthetic mesh materials explanted from human subjects after abdominal wall reconstruction: an analysis of remodeling characteristics by patient risk factors and surgical site classifications

    PubMed Central

    Cavallo, Jaime A.; Roma, Andres A.; Jasielec, Mateusz S.; Ousley, Jenny; Creamer, Jennifer; Pichert, Matthew D.; Baalman, Sara; Frisella, Margaret M.; Matthews, Brent D.

    2014-01-01

    Background The purpose of this study was to evaluate the associations between patient characteristics or surgical site classifications and the histologic remodeling scores of synthetic meshes biopsied from their abdominal wall repair sites in the first attempt to generate a multivariable risk prediction model of non-constructive remodeling. Methods Biopsies of the synthetic meshes were obtained from the abdominal wall repair sites of 51 patients during a subsequent abdominal re-exploration. Biopsies were stained with hematoxylin and eosin, and evaluated according to a semi-quantitative scoring system for remodeling characteristics (cell infiltration, cell types, extracellular matrix deposition, inflammation, fibrous encapsulation, and neovascularization) and a mean composite score (CR). Biopsies were also stained with Sirius Red and Fast Green, and analyzed to determine the collagen I:III ratio. Based on univariate analyses between subject clinical characteristics or surgical site classification and the histologic remodeling scores, cohort variables were selected for multivariable regression models using a threshold p value of ≤0.200. Results The model selection process for the extracellular matrix score yielded two variables: subject age at time of mesh implantation, and mesh classification (c-statistic = 0.842). For CR score, the model selection process yielded two variables: subject age at time of mesh implantation and mesh classification (r2 = 0.464). The model selection process for the collagen III area yielded a model with two variables: subject body mass index at time of mesh explantation and pack-year history (r2 = 0.244). Conclusion Host characteristics and surgical site assessments may predict degree of remodeling for synthetic meshes used to reinforce abdominal wall repair sites. These preliminary results constitute the first steps in generating a risk prediction model that predicts the patients and clinical circumstances for which non-constructive remodeling of an abdominal wall repair site with synthetic mesh reinforcement is most likely to occur. PMID:24442681

  15. Gas gangrene of the abdominal wall due to late-onset enteric fistula after polyester mesh repair of an incisional hernia.

    PubMed

    Moussi, A; Daldoul, S; Bourguiba, B; Othmani, D; Zaouche, A

    2012-04-01

    The occurrence of enteric fistulae after wall repair using a prosthetic mesh is a serious but, fortunately, rare complication. We report the case of a 66-year-old diabetic man who presented with gas gangrene of the abdominal wall due to an intra-abdominal abscess caused by intestinal erosion six years after an incisional hernia repair using a polyester mesh. The aim of this case report is to illustrate the seriousness of enteric fistula after parietal repair using a synthetic material.

  16. Biomechanical properties of synthetic surgical meshes for pelvic prolapse repair.

    PubMed

    Todros, S; Pavan, P G; Natali, A N

    2015-03-01

    Synthetic meshes are widely used for surgical repair of different kind of prolapses. In the light of the experience of abdominal wall repair, similar prostheses are currently used in the pelvic region, to restore physiological anatomy after organ prolapse into the vaginal wall, that represent a recurrent dysfunction. For this purpose, synthetic meshes are surgically positioned in contact with the anterior and/or posterior vaginal wall, to inferiorly support prolapsed organs. Nonetheless, while mesh implantation restores physiological anatomy, it is often associated with different complications in the vaginal region. These potentially dangerous effects induce the surgical community to reconsider the safety and efficacy of mesh transvaginal placement. For this purpose, the evaluation of state-of-the-art research may provide the basis for a comprehensive analysis of mesh compatibility and functionality. The aim of this work is to review synthetic surgical meshes for pelvic organs prolapse repair, taking into account the mechanics of mesh material and structure, and to relate them with pelvic and vaginal tissue biomechanics. Synthetic meshes are currently available in different chemical composition, fiber and textile conformations. Material and structural properties are key factors in determining mesh biochemical and mechanical compatibility in vivo. The most significant results on vaginal tissue and surgical meshes mechanical characterization are here reported and discussed. Moreover, computational models of the pelvic region, which could support the surgeon in the evaluation of mesh performances in physiological conditions, are recalled. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Bubble-Free Containers For Liquids In Microgravity

    NASA Technical Reports Server (NTRS)

    Kornfeld, Dale M.; Antar, Basil L.

    1995-01-01

    Reports discuss entrainment of gas bubbles during handling of liquids in microgravity, and one report proposes containers filled with liquids in microgravity without entraining bubbles. Bubbles are troublesome in low-gravity experiments - particularly in biological experiments. Wire-mesh cage retains liquid contents without solid wall, because in microgravity, surface tension of liquid exerts sufficient confining force.

  18. Chest wall reconstruction in a canine model using polydioxanone mesh, demineralized bone matrix and bone marrow stromal cells.

    PubMed

    Tang, Hua; Xu, Zhifei; Qin, Xiong; Wu, Bin; Wu, Lihui; Zhao, XueWei; Li, Yulin

    2009-07-01

    Extensive chest wall defect reconstruction remains a challenging problem for surgeons. In the past several years, little progress has been made in this area. In this study, a biodegradable polydioxanone (PDO) mesh and demineralized bone matrix (DBM) seeded with osteogenically induced bone marrow stromal cells (BMSCs) were used to reconstruct a 6 cm x 5.5 cm chest wall defect. Four experimental groups were evaluated (n=6 per group): polydioxanone (PDO) mesh/DBMs/BMSCs group, polydioxanone (PDO) mesh/DBMs group, polydioxanone (PDO) mesh group, and a blank group (no materials) in a canine model. All the animals survived except those in the blank group. In all groups receiving biomaterial implants, the polydioxanone (PDO) mesh completely degraded at 24 weeks and was replaced by fibrous tissue with thickness close to that of the normal intercostal tissue (P>0.05). In the polydioxanone (PDO) mesh/DBMs/BMSCs group, new bone formation and bone-union were observed by radiographic and histological examination. More importantly, the reconstructed rib could maintain its original radian and achieve satisfactory biomechanics close to normal ribs in terms of bending stress (P>0.05). However, in the other two groups, fibrous tissue was observed in the defect and junctions, and the reconstructed ribs were easily distorted under an outer force. Based on these results, a surgical approach utilizing biodegradable polydioxanone (PDO) mesh in combination with DBMs and BMSCs could repair the chest wall defect not only in function but also in structure.

  19. Reconstruction of chest wall using a two-layer prolene mesh and bone cement sandwich.

    PubMed

    Aghajanzadeh, Manouchehr; Alavi, Ali; Aghajanzadeh, Gilda; Ebrahimi, Hannan; Jahromi, Sina Khajeh; Massahnia, Sara

    2015-02-01

    Wide surgical resection is the most effective treatment for the vast majority of chest wall tumors. This study evaluated the clinical success of chest wall reconstruction using a Prolene mesh and bone cement prosthetic sandwich. The records of all patients undergoing chest wall resection and reconstruction were reviewed. Surgical indications, the location and size of the chest wall defect, diaphragm resection, pulmonary performance, postoperative complications, and survival of each patient were recorded. From 1998 to 2008, 43 patients (27 male, 16 female; mean age of 48 years) underwent surgery in our department to treat malignant chest wall tumors: chondrosarcoma (23), osteosarcoma (8), spindle cell sarcoma (6), Ewing's sarcoma (2), and others (4). Nine sternectomies and 34 antero-lateral and postero-lateral chest wall resections were performed. Postoperatively, nine patients experienced respiratory complications, and one patient died because of respiratory failure. The overall 4-year survival rate was 60 %. Chest wall reconstruction using a Prolene mesh and bone cement prosthetic sandwich is a safe and effective surgical procedure for major chest wall defects.

  20. SU-E-T-176: Clinical Experience of Brass Mesh Bolus: Patient-Specific Parameters as Predictors of Measured Dosimetric Effect

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yock, A; Manger, R; Einck, J

    2015-06-15

    Purpose: Increasingly, brass mesh bolus is used to insure dosimetric coverage of the skin for patients treated post-mastectomy for breast cancer. Contribution of photoelectrons from interactions between the bolus and the primary beam increases dose superficially without affecting dose at greater depths. We present our experience using brass mesh bolus – including patients for whom the bolus was dosimetrically inadequate – along with analysis of relevant patient-specific parameters. Methods: Optically-stimulated luminescent dosimeters (OSLDs) were used to determine the effect of the bolus for 15 patients. They were positioned beneath the bolus within the tangent fields at three positions: 1.5–3cm insidemore » the medial and lateral field edges, and midway between the two. All OSLDs were midfield in the cranial-caudal direction. The measurements were compared with patient-specific parameters including separation, chest wall/breast tissue thickness, beam angle incidence, and planned surface dose. Results: The average OSLD measurement at the medial field edge, midfield, and lateral field edge position was 86.8%, 101.8%, and 92.8% of the prescription dose, respectively. A measurement for one patient was low enough (77.0%) to warrant a switch to an alternative type of bolus. Anatomic parameters were analyzed to investigate the low dose in this case, not observed in the planning system. The patient was observed to have a thin chest wall and very oblique beam angles. A second patient was also switched to an alternative type of bolus due to her being high risk and treated with an electron patch that extended onto the breast. Conclusion: Brass mesh bolus increases dose superficially while leaving dose at greater depths unaffected. However, our results suggest that this effect may be insufficient in patients with a thin chest wall or very oblique beam angles. More data and analysis is necessary to proactively identify patients for whom brass mesh bolus is effective.« less

  1. Reconstruction of Midface and Orbital Wall Defects After Maxillectomy and Orbital Content Preservation With Titanium Mesh and Fascia Lata: 3-Year Follow-Up.

    PubMed

    Motiee-Langroudi, Maziar; Harirchi, Iraj; Amali, Amin; Jafari, Mehrdad

    2015-12-01

    To describe the authors' experience in the reconstruction of patients after total maxillectomy with preservation of orbital contents for maxillary tumors using titanium mesh and autogenous fascia lata, where no setting for free flap reconstruction is available. Twelve consecutive patients with paranasal sinus tumors underwent total maxillectomy without orbital exenterations and primary reconstruction. The defects were reconstructed by titanium mesh in combination with autogenous fascia lata in the orbital floor performed by 1 surgical team. Titanium mesh (0.2 mm thick) was contoured and fixed to reconstruct the orbital floor and obtain midface projection. Fascia lata was used to cover the titanium mesh along the orbital floor to prevent fat entrapment in the mesh holes. The most common pathology was squamous cell carcinoma (50%). Patients' mean age was 45.66 years (33 to 74 yr). The mean follow-up period was 35.2 months (30 to 49 months). During follow-up, no infection or foreign body reaction was encountered. Extrusion of titanium mesh occurred in 4 patients who underwent postoperative radiotherapy. Two cases of mild diplopia at extreme gaze occurred early during the postoperative period that resolved after a few months. Placing fascia lata between the titanium mesh surface of the orbital implant and the orbital contents was successful in preventing long-term diplopia or dystopia. Nevertheless, exposure of the titanium implant through the skin surface represented a complication of this technique in 25% of patients. Further studies are required with head-to-head comparisons of artificial materials and free flaps for reconstruction of maxillectomy defects. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Energy loss from a moving vortex in superfluid helium

    NASA Astrophysics Data System (ADS)

    Zieve, R. J.; Frei, C. M.; Wolfson, D. L.

    2012-11-01

    We present measurements on both energy loss and pinning for a vortex terminating on the curved surface of a cylindrical container. We vary surface roughness, cell diameter, fluid velocity, and temperature. Although energy loss and pinning both arise from interactions between the vortex and the surface, their dependences on the experimental parameters differ, suggesting that different mechanisms govern the two effects. We propose that the energy loss stems from reconnections with a mesh of microscopic vortices that covers the cell wall, while pinning is dominated by other influences such as the local fluid velocity.

  3. A hybrid multiview stereo algorithm for modeling urban scenes.

    PubMed

    Lafarge, Florent; Keriven, Renaud; Brédif, Mathieu; Vu, Hoang-Hiep

    2013-01-01

    We present an original multiview stereo reconstruction algorithm which allows the 3D-modeling of urban scenes as a combination of meshes and geometric primitives. The method provides a compact model while preserving details: Irregular elements such as statues and ornaments are described by meshes, whereas regular structures such as columns and walls are described by primitives (planes, spheres, cylinders, cones, and tori). We adopt a two-step strategy consisting first in segmenting the initial meshbased surface using a multilabel Markov Random Field-based model and second in sampling primitive and mesh components simultaneously on the obtained partition by a Jump-Diffusion process. The quality of a reconstruction is measured by a multi-object energy model which takes into account both photo-consistency and semantic considerations (i.e., geometry and shape layout). The segmentation and sampling steps are embedded into an iterative refinement procedure which provides an increasingly accurate hybrid representation. Experimental results on complex urban structures and large scenes are presented and compared to state-of-the-art multiview stereo meshing algorithms.

  4. Explicitly represented polygon wall boundary model for the explicit MPS method

    NASA Astrophysics Data System (ADS)

    Mitsume, Naoto; Yoshimura, Shinobu; Murotani, Kohei; Yamada, Tomonori

    2015-05-01

    This study presents an accurate and robust boundary model, the explicitly represented polygon (ERP) wall boundary model, to treat arbitrarily shaped wall boundaries in the explicit moving particle simulation (E-MPS) method, which is a mesh-free particle method for strong form partial differential equations. The ERP model expresses wall boundaries as polygons, which are explicitly represented without using the distance function. These are derived so that for viscous fluids, and with less computational cost, they satisfy the Neumann boundary condition for the pressure and the slip/no-slip condition on the wall surface. The proposed model is verified and validated by comparing computed results with the theoretical solution, results obtained by other models, and experimental results. Two simulations with complex boundary movements are conducted to demonstrate the applicability of the E-MPS method to the ERP model.

  5. Resterilized mesh in repair of abdominal wall defects in rats.

    PubMed

    Sucullu, Ilker; Akin, Mehmet Levhi; Yitgin, Selahattin; Filiz, Ali Ilker; Kurt, Yavuz

    2008-01-01

    A variety of negative opinions about repeated usage of relatively expensive resterilized synthetic meshes have been considered. It had been stated that resterilized polypropylene meshes inhibits fibroblastic activity, decreases proliferative activity, and increases apoptosis in human fibroblast culture, in vitro. The purpose of this study is the in vivo evaluation of the resterilized mesh repairs of abdominal hernia defects in rat models of incisional hernia by comparing primer repair and original mesh repairs. The rats (n = 22) were separated into three groups. While the abdominal defect was repaired by primary suture in the control group (CG), the defects were repaired by original mesh (OG) or resterilized mesh (RG) in mesh-repaired groups. After 21 days, the rats were evaluated for tissue tensile strengths, tissue hydroxyproline levels, tissue inflammation, fibrosis, and apoptosis. Although the tensile strengths in OG and RG were significantly higher than those of CG (p < .05 and p < .05), there was no significant difference between two groups. The tissue hydroxyproline levels in OG and RG were also higher than those of CG. The difference was not significant between the two groups. The inflammation and fibrosis indexes in OG and RG were significantly higher than those of CG (p < .0001 for both), but there was no difference between groups. While the apoptosis index in OG and RG was also higher than that of CG (p < .0001 for both), there was no significant difference between OG and RG. The usage of resterilized mesh in abdominal wall repair did not reduce the tissue tensile strength, did not affect the tissue hydroxyproline levels, did not decrease the fibrosis, and did not increase the tissue inflammation and apoptosis. In conclusion, usage of resterilized meshes in abdominal wall defects was as safe as sterilized meshes.

  6. Conservative management of mesh-site infection in hernia repair surgery: a case series.

    PubMed

    Meagher, H; Clarke Moloney, M; Grace, P A

    2015-04-01

    The aim of this study is to assess the outcome of conservative management of infected mesh grafts following abdominal wall hernia repair. This study retrospectively examined the charts of patients who developed mesh-site infection following surgery for abdominal hernia repair to determine how effective conservative management in the form of antibiotics and wound management was on the resolution of infection and wound healing. Over a period of 30 months, 13 patients developed infected mesh grafts post-hernia repair surgery. Twelve patients were successfully treated conservatively with local wound care and antibiotics if clinically indicated. One patient returned to theatre to have the infected mesh removed. Of the patients that healed eleven were treated with negative pressure wound therapy (VAC(®)). This series of case studies indicate that conservative management of abdominal wall-infected hernia mesh cases is likely to be successful.

  7. Safety of silastic sheet for orbital wall reconstruction.

    PubMed

    Moon, Seong June; Suh, Hyun Suk; Park, Bo Young; Kang, So Ra

    2014-07-01

    Many implants are being used for the reconstruction of orbital wall fractures. The effect of the choice of implant for the reconstruction of an orbital wall fracture on the surgical outcome is under debate. The purpose of this article is to compare the outcomes of orbital wall reconstruction of small orbital wall fractures on the basis of the implants used. The authors conducted a retrospective study using electronic databases. Between March 2001 and December 2012, 461 patients with orbital wall fractures were included in this study. Among them, 431 patients in whom the fracture size was less than 300 mm(2) were analyzed. The fracture size was calculated using computed tomography scans of the orbit in the sagittal and coronal images. Cases in which the fracture size was less than 300 mm(2) were included in this study. One hundred and twenty-nine patients were treated with silastic sheets; 238 patients were treated with titanium meshes; and absorbable meshes were used in the case of 64 patients. Overall, 13 patients required revision, and the revision rate was 3.0%. The revision rate of the silastic sheet group was 5.4%. In the multivariable analysis, the revision rate of the group reconstructed with silastic sheets was highly statistically significant (P=0.043, odds ratio=3.65). However, other factors such as age, sex, fracture type, and fracture size were not significant. Reconstruction of orbital wall fractures with silastic sheets may cause more complications than that with other materials such as titanium meshes and absorbable meshes.

  8. Definitive Surgical Treatment of Infected or Exposed Ventral Hernia Mesh

    PubMed Central

    Szczerba, Steven R.; Dumanian, Gregory A.

    2003-01-01

    Objective To discuss the difficulties in dealing with infected or exposed ventral hernia mesh, and to illustrate one solution using an autogenous abdominal wall reconstruction technique. Summary Background Data The definitive treatment for any infected prosthetic material in the body is removal and substitution. When ventral hernia mesh becomes exposed or infected, its removal requires a solution to prevent a subsequent hernia or evisceration. Methods Eleven patients with ventral hernia mesh that was exposed, nonincorporated, with chronic drainage, or associated with a spontaneous enterocutaneous fistula were referred by their initial surgeons after failed local wound care for definitive management. The patients were treated with radical en bloc excision of mesh and scarred fascia followed by immediate abdominal wall reconstruction using bilateral sliding rectus abdominis myofascial advancement flaps. Results Four of the 11 patients treated for infected mesh additionally required a bowel resection. Transverse defect size ranged from 8 to 18 cm (average 13 cm). Average procedure duration was 3 hours without bowel repair and 5 hours with bowel repair. Postoperative length of stay was 5 to 7 days without bowel repair and 7 to 9 days with bowel repair. Complications included hernia recurrence in one case and stitch abscesses in two cases. Follow-up ranges from 6 to 54 months (average 24 months). Conclusions Removal of infected mesh and autogenous flap reconstruction is a safe, reliable, and one-step surgical solution to the problem of infected abdominal wall mesh. PMID:12616130

  9. Polypropylene-based composite mesh versus standard polypropylene mesh in the reconstruction of complicated large abdominal wall hernias: a prospective randomized study.

    PubMed

    Kassem, M I; El-Haddad, H M

    2016-10-01

    To compare polypropylene mesh positioned onlay supported by omentum and/or peritoneum versus inlay implantation of polypropylene-based composite mesh in patients with complicated wide-defect ventral hernias. This was a prospective randomized study carried out on 60 patients presenting with complicated large ventral hernia in the period from January 2012 to January 2016 in the department of Gastrointestinal Surgery unit and Surgical Emergency of the Main Alexandria University Hospital, Egypt. Large hernia had an abdominal wall defect that could not be closed. Patients were divided into two groups of 30 patients according to the type of mesh used to deal with the large abdominal wall defect. The study included 38 women (63.3 %) and 22 men (37.7 %); their mean age was 46.5 years (range, 25-70). Complicated incisional hernia was the commonest presentation (56.7 %).The operative and mesh fixation times were longer in the polypropylene group. Seven wound infections and two recurrences were encountered in the propylene group. Mean follow-up was 28.7 months (2-48 months). Composite mesh provided, in one session, satisfactory results in patients with complicated large ventral hernia. The procedure is safe and effective in lowering operative time with a trend of low wound complication and recurrence rates.

  10. A Methodology for the Derivation of Unloaded Abdominal Aortic Aneurysm Geometry With Experimental Validation

    PubMed Central

    Chandra, Santanu; Gnanaruban, Vimalatharmaiyah; Riveros, Fabian; Rodriguez, Jose F.; Finol, Ender A.

    2016-01-01

    In this work, we present a novel method for the derivation of the unloaded geometry of an abdominal aortic aneurysm (AAA) from a pressurized geometry in turn obtained by 3D reconstruction of computed tomography (CT) images. The approach was experimentally validated with an aneurysm phantom loaded with gauge pressures of 80, 120, and 140 mm Hg. The unloaded phantom geometries estimated from these pressurized states were compared to the actual unloaded phantom geometry, resulting in mean nodal surface distances of up to 3.9% of the maximum aneurysm diameter. An in-silico verification was also performed using a patient-specific AAA mesh, resulting in maximum nodal surface distances of 8 μm after running the algorithm for eight iterations. The methodology was then applied to 12 patient-specific AAA for which their corresponding unloaded geometries were generated in 5–8 iterations. The wall mechanics resulting from finite element analysis of the pressurized (CT image-based) and unloaded geometries were compared to quantify the relative importance of using an unloaded geometry for AAA biomechanics. The pressurized AAA models underestimate peak wall stress (quantified by the first principal stress component) on average by 15% compared to the unloaded AAA models. The validation and application of the method, readily compatible with any finite element solver, underscores the importance of generating the unloaded AAA volume mesh prior to using wall stress as a biomechanical marker for rupture risk assessment. PMID:27538124

  11. Virtual simulation of the postsurgical cosmetic outcome in patients with Pectus Excavatum

    NASA Astrophysics Data System (ADS)

    Vilaça, João L.; Moreira, António H. J.; L-Rodrigues, Pedro; Rodrigues, Nuno; Fonseca, Jaime C.; Pinho, A. C. M.; Correia-Pinto, Jorge

    2011-03-01

    Pectus excavatum is the most common congenital deformity of the anterior chest wall, in which several ribs and the sternum grow abnormally. Nowadays, the surgical correction is carried out in children and adults through Nuss technic. This technic has been shown to be safe with major drivers as cosmesis and the prevention of psychological problems and social stress. Nowadays, no application is known to predict the cosmetic outcome of the pectus excavatum surgical correction. Such tool could be used to help the surgeon and the patient in the moment of deciding the need for surgery correction. This work is a first step to predict postsurgical outcome in pectus excavatum surgery correction. Facing this goal, it was firstly determined a point cloud of the skin surface along the thoracic wall using Computed Tomography (before surgical correction) and the Polhemus FastSCAN (after the surgical correction). Then, a surface mesh was reconstructed from the two point clouds using a Radial Basis Function algorithm for further affine registration between the meshes. After registration, one studied the surgical correction influence area (SCIA) of the thoracic wall. This SCIA was used to train, test and validate artificial neural networks in order to predict the surgical outcome of pectus excavatum correction and to determine the degree of convergence of SCIA in different patients. Often, ANN did not converge to a satisfactory solution (each patient had its own deformity characteristics), thus invalidating the creation of a mathematical model capable of estimating, with satisfactory results, the postsurgical outcome.

  12. Do patients prefer mesh or anterior colporrhaphy for primary correction of anterior vaginal wall prolapse: a labelled discrete choice experiment.

    PubMed

    Notten, K J B; Essers, B A; Weemhoff, M; Rutten, A G H; Donners, J J A E; van Gestel, I; Kruitwagen, R F P M; Roovers, J P W R; Dirksen, C D

    2015-05-01

    We investigated patients' preferences for anterior colporrhaphy or mesh surgery as surgical correction of anterior vaginal wall prolapse. Labelled discrete choice experiment. Three Dutch teaching hospitals. Women with anterior vaginal wall prolapse Pelvic Organ Prolapse Quantification stage 2 or more, indicated for anterior colporrhaphy (n = 100). Discrete choice experiments are an attribute-based survey method for measuring preferences. In this experiment, women were asked to choose between two treatment scenarios, mesh surgery or anterior colporrhaphy. These surgical treatments differed in four treatment attributes: (i) recurrence rate, (ii) exposure rate, (iii) infection rate, (iv) dyspareunia. Data were analysed using a multinomial logit model. Women's preferences for anterior colporrhaphy or mesh surgery for the repair of vaginal wall prolapse. All treatment attributes, i.e. recurrence, exposure, infection and dyspareunia, proved to be significant in the woman's decision to choose mesh surgery (P < 0.001), while only two attributes out of three, recurrence and infection, were significant for anterior colporrhaphy (P < 0.001). The relative importance data showed that with regards to the four statistically significant attributes for mesh, dyspareunia was the most important attribute, and of the two significant attributes for anterior colporrhaphy, the risk of infection. Based on the attributes and levels in our discrete choice experiment, anterior colporrhaphy was preferred in 74% as a primary correction of anterior vaginal wall prolapse, followed by a preference for mesh in 26% of all choices. This study showed that next to the risk of recurrence, other aspects like risk of infection, dyspareunia and exposure play a role in the woman's preference for a surgical treatment. In addition, our results indicate that anterior colporrhaphy is preferred in the majority of the choices, followed by a preference for mesh surgery in a quarter of all choice sets. However, these results represent the average preference of a sample of women and cannot be taken as the preference of each individual. In the medical decision-making context, information from the current study should be personalised to fit patient's unique circumstances. For patients to construct their own, individual preferences, they should be well informed about the existence and magnitude of the potential benefits and risks related to either anterior colporrhaphy or mesh surgery. © 2014 Royal College of Obstetricians and Gynaecologists.

  13. Monitoring the Wall Mechanics During Stent Deployment in a Vessel

    PubMed Central

    Steinert, Brian D.; Zhao, Shijia; Gu, Linxia

    2012-01-01

    Clinical trials have reported different restenosis rates for various stent designs1. It is speculated that stent-induced strain concentrations on the arterial wall lead to tissue injury, which initiates restenosis2-7. This hypothesis needs further investigations including better quantifications of non-uniform strain distribution on the artery following stent implantation. A non-contact surface strain measurement method for the stented artery is presented in this work. ARAMIS stereo optical surface strain measurement system uses two optical high speed cameras to capture the motion of each reference point, and resolve three dimensional strains over the deforming surface8,9. As a mesh stent is deployed into a latex vessel with a random contrasting pattern sprayed or drawn on its outer surface, the surface strain is recorded at every instant of the deformation. The calculated strain distributions can then be used to understand the local lesion response, validate the computational models, and formulate hypotheses for further in vivo study. PMID:22588353

  14. Selecting criteria for the right prosthesis in defect of the abdominal wall surgery.

    PubMed

    Mohamed, H; Ion, D; Serban, M B; Ciurea, M

    2009-01-01

    The article is debating a theme of great interest for the defect of the abdominal wall surgery--the use of biocompatible prosthesis. The surgeon is often confused by the avalanche of offers made by the mesh producers, making it mandatory for him to know very well the behavior of these alloplastic structures in the tissue environment. From this point of view, we have discussed both the physicochemical properties and the histological reaction brought by the most common type of meshes: polypropylene, polyethylene - tereftalat, polytetrafluorideethylene. This presentation brings out the minimal but mandatory criteria for any mesh to be accepted, but also the criteria that need to be taken into consideration when we try to improve the qualities of the mesh closer to the desideratum of the "ideal mesh". The main conclusion of this review is that we have to change the myth of the "ideal mesh" with "the right chosen mesh", that based on its chemical, physical, structural and biological qualities will adapt perfectly first to the patient's needs and second to the surgeon's needs.

  15. Learning curves in abdominal wall reconstruction with components separation: one step closer toward improving outcomes and reducing complications.

    PubMed

    Hultman, Charles Scott; Clayton, John L; Kittinger, Benjamin J; Tong, Winnie M

    2014-01-01

    Learning curves are characterized by incremental improvement of a process, through repetition and reduction in variability, but can be disrupted with the emergence of new techniques and technologies. Abdominal wall reconstruction continues to evolve, with the introduction of components separation in the 1990s and biologic mesh in the 2000s. As such, attempts at innovation may impact the success of reconstructive outcomes and yield a changing set of complications. The purpose of this project was to describe the paradigm shift that has occurred in abdominal wall reconstruction during the past 10 years, focusing on the incorporation of new materials and methods. We reviewed 150 consecutive patients who underwent abdominal wall reconstruction of midline defects with components separation, from 2000 to 2010. Both univariate and multivariate logistic regression analyses were performed to identify risk factors for complications. Patients were stratified into the following periods: early (2000-2003), middle (2004-2006), and late (2007-2010). From 2000 to 2010, we performed 150 abdominal wall reconstructions with components separation [mean age, 50.2 years; body mass index (BMI), 30.4; size of defect, 357 cm; length of stay, 9.6 days; follow-up, 4.4 years]. Primary fascial closure was performed in 120 patients. Mesh was used in 114 patients in the following locations: overlay (n = 28), inlay (n = 30), underlay (n = 54), and unknown (n = 2). Complications occurred in a bimodal distribution, highest in 2001 (introduction of biologic mesh) and 2008 (conversion from underlay to overlay location). Age, sex, history of smoking, defect size, and length of stay were not associated with incidence of complications. Unadjusted risk factors for seroma (16.8%) were elevated BMI, of previous hernia repairs, use of overlay mesh, and late portion of the learning curve, with logistic regression supporting only late portion of the learning curve [odds ratio (OR), 4.3; 95% confidence interval (CI), 1.0-18.6] and BMI (OR, 1.17; 95% CI, 1.06-1.29). The only unadjusted risk factor for recurrence was location of mesh. Logistic regression, comparing underlay, inlay, and overlay mesh to no mesh, revealed that the use of underlay mesh predicted recurrence (OR, 3.0; 95% CI, 1.04-8.64). All P values were less than 0.05. The overall learning curve for a specific procedure, such as abdominal wall reconstruction, can be quite volatile, especially as innovative techniques and new technologies are introduced and incorporated into the surgeon's practice. Our current practice includes primary repair myofascial flap of the components separation and the use of biologic mesh as an overlay graft, anchored to the external oblique. This process of outcome improvement is not gradual but is often punctuated by periods of failure and redemption.

  16. [The cutaneous groin flap for coverage of a full-thickness abdominal wall defect].

    PubMed

    Doebler, O; Spierer, R

    2010-08-01

    A full-thickness defect of the abdominal wall is rare and may occur as a complication of extended abdominal surgery procedures. We report about a 69-year-old patient who was presented to our department with a full-thickness abdominal wall defect and a fully exposed collagen-mesh for reconstructive wound closure. 13 operations with resections of necrotic parts of the abdominal wall were performed following a complicated intraabdominal infection. After debridement and mesh explantation, closure of the remaining defect of the lower abdominal region was achieved by a cutaneous groin flap. Georg Thieme Verlag KG Stuttgart New York.

  17. Adaptive mesh refinement and load balancing based on multi-level block-structured Cartesian mesh

    NASA Astrophysics Data System (ADS)

    Misaka, Takashi; Sasaki, Daisuke; Obayashi, Shigeru

    2017-11-01

    We developed a framework for a distributed-memory parallel computer that enables dynamic data management for adaptive mesh refinement and load balancing. We employed simple data structure of the building cube method (BCM) where a computational domain is divided into multi-level cubic domains and each cube has the same number of grid points inside, realising a multi-level block-structured Cartesian mesh. Solution adaptive mesh refinement, which works efficiently with the help of the dynamic load balancing, was implemented by dividing cubes based on mesh refinement criteria. The framework was investigated with the Laplace equation in terms of adaptive mesh refinement, load balancing and the parallel efficiency. It was then applied to the incompressible Navier-Stokes equations to simulate a turbulent flow around a sphere. We considered wall-adaptive cube refinement where a non-dimensional wall distance y+ near the sphere is used for a criterion of mesh refinement. The result showed the load imbalance due to y+ adaptive mesh refinement was corrected by the present approach. To utilise the BCM framework more effectively, we also tested a cube-wise algorithm switching where an explicit and implicit time integration schemes are switched depending on the local Courant-Friedrichs-Lewy (CFL) condition in each cube.

  18. Method and apparatus for connecting finite element meshes and performing simulations therewith

    DOEpatents

    Dohrmann, Clark R.; Key, Samuel W.; Heinstein, Martin W.

    2003-05-06

    The present invention provides a method of connecting dissimilar finite element meshes. A first mesh, designated the master mesh, and a second mesh, designated the slave mesh, each have interface surfaces proximal the other. Each interface surface has a corresponding interface mesh comprising a plurality of interface nodes. Each slave interface node is assigned new coordinates locating the interface node on the interface surface of the master mesh. The slave interface surface is further redefined to be the projection of the slave interface mesh onto the master interface surface.

  19. Adaptive Skin Meshes Coarsening for Biomolecular Simulation

    PubMed Central

    Shi, Xinwei; Koehl, Patrice

    2011-01-01

    In this paper, we present efficient algorithms for generating hierarchical molecular skin meshes with decreasing size and guaranteed quality. Our algorithms generate a sequence of coarse meshes for both the surfaces and the bounded volumes. Each coarser surface mesh is adaptive to the surface curvature and maintains the topology of the skin surface with guaranteed mesh quality. The corresponding tetrahedral mesh is conforming to the interface surface mesh and contains high quality tetrahedral that decompose both the interior of the molecule and the surrounding region (enclosed in a sphere). Our hierarchical tetrahedral meshes have a number of advantages that will facilitate fast and accurate multigrid PDE solvers. Firstly, the quality of both the surface triangulations and tetrahedral meshes is guaranteed. Secondly, the interface in the tetrahedral mesh is an accurate approximation of the molecular boundary. In particular, all the boundary points lie on the skin surface. Thirdly, our meshes are Delaunay meshes. Finally, the meshes are adaptive to the geometry. PMID:21779137

  20. Stabilization of the Chest Wall: Autologous and Alloplastic Reconstructions

    PubMed Central

    Mahabir, Raman Chaos; Butler, Charles E.

    2011-01-01

    The goals of chest wall stabilization include maintenance of a rigid airtight cavity, protection of the thoracic and abdominal contents, optimization of respiration, and, whenever possible, an aesthetic reconstruction. Evidence suggests that bony fixation results in reduced ventilator dependence, a shorter overall hospital stay, and improved upper extremity function. We prefer to accomplish this with autologous tissue alone (such as the pectoralis major, latissimus dorsi, or rectus abdominus muscle flaps) for small to moderate defects. En bloc resection of defects larger than 5 cm or containing four or more ribs will likely benefit from chest wall stabilization. For patients previously treated with radiation, even larger defects may be tolerated owing to fibrosis. For these larger defects, methyl methacrylate composite meshes are used and covered with vascularized tissue. Contaminated wounds are generally reconstructed with bioprosthetic mesh rather than synthetic mesh. Using these principles, the reconstructive plastic surgeon can devise a comprehensive and safe plan to repair tremendous defects of the chest wall. PMID:22294941

  1. Bovine versus porcine acellular dermal matrix for complex abdominal wall reconstruction.

    PubMed

    Clemens, Mark W; Selber, Jesse C; Liu, Jun; Adelman, David M; Baumann, Donald P; Garvey, Patrick B; Butler, Charles E

    2013-01-01

    Abdominal wall reconstruction with bioprosthetic mesh is associated with lower rates of mesh infection, fistula formation, and mesh explantation than reconstruction with synthetic mesh. The authors directly compared commonly used bioprosthetic meshes in terms of clinical outcomes and complications. A database of consecutive patients who underwent abdominal wall reconstruction with porcine or bovine acellular dermal matrix and midline musculofascial closure at their institution between January of 2008 and March of 2011 was reviewed. Surgical outcomes were compared. One hundred twenty patients were identified who underwent a nonbridged, inlay abdominal wall reconstruction with porcine [69 patients (57.5 percent)] or bovine acellular dermal matrix (51 patients (42.5 percent)]. The mean follow-up time was 21.0 ± 9.9 months. The overall complication rate was 36.6 percent; the porcine matrix group had a significantly higher complication rate (44.9 percent) than the bovine matrix group (25.5 percent; p = 0.04) and statistically equivalent surgical complications (29.2 percent versus 21.6 percent; p = 0.34). There were no significant differences in rates of recurrent hernia (2.9 percent versus 3.9 percent; p = 0.99) or bulge (7.2 percent versus 0 percent; p = 0.07). However, the rate of intraoperative adverse events in the porcine matrix group [seven events (10.1 percent)] was significantly higher than that in the bovine matrix group (0 percent; p = 0.02). In patients who undergo complex abdominal wall reconstruction, both bovine and porcine acellular dermal matrix are associated with similar rates of postoperative surgical complications and appear to result in similar outcomes. Porcine acellular dermal matrix may be prone to intraoperative device failure. Therapeutic, III.

  2. Donor-site morbidity after pedicled TRAM breast reconstruction: a comparison of two different types of mesh.

    PubMed

    Sværdborg, Mille; Damsgaard, Tine Engberg

    2013-11-01

    Many different approaches have been used to minimize the risk of bulge or hernia formation when using autologous abdominal tissue for breast reconstruction. Studies have shown that further reinforcement of the abdominal wall using a mesh may decrease the complication rate.The current study included 40 consecutive patients having unilateral breast reconstruction with the pedicled transverse rectus abdominus musculocutaneous flap. The defect in the abdominal fascia was closed primarily and further reinforced using a Prolene mesh (Ethicon), n = 20, or using a self-fixating Parietex ProGrip mesh (Covidien), n = 20. The patients were examined at an outpatient consultation, with a minimum follow-up of 1 year and questioned about donor-site symptoms using a standardized questionnaire.Of the 20 patients in the Prolene group, 2 (10%) developed abdominal wall bulging, and of the 20 patients in the ProGrip group, 11 (55%) developed abdominal wall bulging (P = 0.006). In both the Prolene and the ProGrip group, most patients reported having continued donor-site symptoms at the time of the follow-up (70% and 80%, respectively); 15% and 30%, respectively, reported having symptoms that influenced their daily or physical activities (not a significant difference). All but 1 patient in our study reported being very happy with the reconstruction and would have done it again, had they known what they did at the time of the follow-up.We conclude that the self-gripping properties of the Parietex ProGrip mesh are not sufficient in withstanding the abdominal wall tension at the donor site after transverse rectus abdominus musculocutaneous-flap harvest and do not recommend using the Parietex ProGrip mesh without fixating sutures for this procedure.

  3. Numerical investigations in three-dimensional internal flows

    NASA Astrophysics Data System (ADS)

    Rose, William C.

    1988-08-01

    An investigation into the use of computational fluid dynamics (CFD) was performed to examine the expected heat transfer rates that will occur within the NASA-Ames 100 megawatt arc heater nozzle. This nozzle was tentatively designed and identified to provide research for a directly connected combustion experiment specifically related to the National Aerospace Plane Program (NASP) aircraft, and is expected to simulate the flow field entering the combustor section. It was found that extremely fine grids, that is very small mesh spacing near the wall, are required to accurately model the heat transfer process and, in fact, must contain a point within the laminar sublayer if results are to be taken directly from a numerical simulation code. In the present study, an alternative to this very fine mesh and its attendant increase in computational time was invoked and is based on a wall-function method. It was shown that solutions could be obtained that give accurate indications of surface heat transfer rate throughout the nozzle in approximately 1/100 of the computer time required to do the simulation directly without the use of the wall-function implementation. Finally, a maximum heating value in the throat region of the proposed slit nozzle for the 100 megawatt arc heater was shown to be approximately 6 MW per square meter.

  4. Early biocompatibility of crosslinked and non-crosslinked biologic meshes in a porcine model of ventral hernia repair.

    PubMed

    Melman, L; Jenkins, E D; Hamilton, N A; Bender, L C; Brodt, M D; Deeken, C R; Greco, S C; Frisella, M M; Matthews, B D

    2011-04-01

    Biologic meshes have unique physical properties as a result of manufacturing techniques such as decellularization, crosslinking, and sterilization. The purpose of this study is to directly compare the biocompatibility profiles of five different biologic meshes, AlloDerm(®) (non-crosslinked human dermal matrix), PeriGuard(®) (crosslinked bovine pericardium), Permacol(®) (crosslinked porcine dermal matrix), Strattice(®) (non-crosslinked porcine dermal matrix), and Veritas(®) (non-crosslinked bovine pericardium), using a porcine model of ventral hernia repair. Full-thickness fascial defects were created in 20 Yucatan minipigs and repaired with the retromuscular placement of biologic mesh 3 weeks later. Animals were euthanized at 1 month and the repair sites were subjected to tensile testing and histologic analysis. Samples of unimplanted (de novo) meshes and native porcine abdominal wall were also analyzed for their mechanical properties. There were no significant differences in the biomechanical characteristics between any of the mesh-repaired sites at 1 month postimplantation or between the native porcine abdominal wall without implanted mesh and the mesh-repaired sites (P > 0.05 for all comparisons). Histologically, non-crosslinked materials exhibited greater cellular infiltration, extracellular matrix (ECM) deposition, and neovascularization compared to crosslinked meshes. While crosslinking differentiates biologic meshes with regard to cellular infiltration, ECM deposition, scaffold degradation, and neovascularization, the integrity and strength of the repair site at 1 month is not significantly impacted by crosslinking or by the de novo strength/stiffness of the mesh.

  5. Prostheses size dependency of the mechanical response of the herniated human abdomen.

    PubMed

    Simón-Allué, R; Hernández-Gascón, B; Lèoty, L; Bellón, J M; Peña, E; Calvo, B

    2016-12-01

    Hernia repairs still exhibit clinical complications, i.e. recurrence, discomfort and pain and mesh features are thought to be highly influent. The aim of this study is to evaluate the impact of the defect size and mesh type in an herniated abdominal wall using numerical models. To do so, we have started from a FE model based on a real human abdomen geometry obtained by MRI, where we have provoked an incisional hernia of three different sizes. The surgical procedure was simulated by covering the hernia with a prostheses, and three surgical meshes with distinct mechanical properties were used for the hernia repair: an isotropic heavy-weight mesh (Surgipro @ ), a slightly anisotropic light-weight mesh (Optilene @ ) and a highly anisotropic medium-weight mesh (Infinit @ ). The mechanical response of the wall to a high intraabdominal pressure (corresponding to a coughing motion) was analyzed here. Our findings suggest that the anisotropy of the mesh becomes more relevant with the increase of the defect size. Additionally, according to our results Optilene @ showed the closest deformation to the natural distensibility of the abdomen while Infinit @ should be carefully used due to its excessive compliance.

  6. Animating Wall-Bounded Turbulent Smoke via Filament-Mesh Particle-Particle Method.

    PubMed

    Liao, Xiangyun; Si, Weixin; Yuan, Zhiyong; Sun, Hanqiu; Qin, Jing; Wang, Qiong; Heng, Pheng-Ann; Xiangyun Liao; Weixin Si; Zhiyong Yuan; Hanqiu Sun; Jing Qin; Qiong Wang; Pheng-Ann Heng

    2018-03-01

    Turbulent vortices in smoke flows are crucial for a visually interesting appearance. Unfortunately, it is challenging to efficiently simulate these appealing effects in the framework of vortex filament methods. The vortex filaments in grids scheme allows to efficiently generate turbulent smoke with macroscopic vortical structures, but suffers from the projection-related dissipation, and thus the small-scale vortical structures under grid resolution are hard to capture. In addition, this scheme cannot be applied in wall-bounded turbulent smoke simulation, which requires efficiently handling smoke-obstacle interaction and creating vorticity at the obstacle boundary. To tackle above issues, we propose an effective filament-mesh particle-particle (FMPP) method for fast wall-bounded turbulent smoke simulation with ample details. The Filament-Mesh component approximates the smooth long-range interactions by splatting vortex filaments on grid, solving the Poisson problem with a fast solver, and then interpolating back to smoke particles. The Particle-Particle component introduces smoothed particle hydrodynamics (SPH) turbulence model for particles in the same grid, where interactions between particles cannot be properly captured under grid resolution. Then, we sample the surface of obstacles with boundary particles, allowing the interaction between smoke and obstacle being treated as pressure forces in SPH. Besides, the vortex formation region is defined at the back of obstacles, providing smoke particles flowing by the separation particles with a vorticity force to simulate the subsequent vortex shedding phenomenon. The proposed approach can synthesize the lost small-scale vortical structures and also achieve the smoke-obstacle interaction with vortex shedding at obstacle boundaries in a lightweight manner. The experimental results demonstrate that our FMPP method can achieve more appealing visual effects than vortex filaments in grids scheme by efficiently simulating more vivid thin turbulent features.

  7. Open and Laparo-Endoscopic Repair of Incarcerated Abdominal Wall Hernias by the Use of Biological and Biosynthetic Meshes.

    PubMed

    Fortelny, René H; Hofmann, Anna; May, Christopher; Köckerling, Ferdinand

    2016-01-01

    Although recently published guidelines recommend against the use of synthetic non-absorbable materials in cases of potentially contaminated or contaminated surgical fields due to the increased risk of infection (1, 2), the use of bio-prosthetic meshes for abdominal wall or ventral hernia repair is still controversially discussed in such cases. Bio-prosthetic meshes have been recommended due to less susceptibility for infection and the decreased risk of subsequent mesh explantation. The purpose of this review is to elucidate if there are any indications for the use of biological and biosynthetic meshes in incarcerated abdominal wall hernias based on the recently published literature. A literature search of the Medline database using the PubMed search engine, using the keywords returned 486 articles up to June 2015. The full text of 486 articles was assessed and 13 relevant papers were identified including 5 retrospective case cohort studies, 2 case-controlled studies, and 6 case series. The results of Franklin et al. (3-5) included the highest number of biological mesh repairs (Surgisis(®)) by laparoscopic IPOM in infected fields, which demonstrated a very low incidence of infection and recurrence (0.7 and 5.2%). Han et al. (6) reported in his retrospective study, the highest number of treated patients due to incarcerated hernias by open approach using acellular dermal matrix (ADM(®)) with very low rate of infection as well as recurrences (1.6 and 15.9%). Both studies achieved acceptable outcome in a follow-up of at least 3.5 years compared to the use of synthetic mesh in this high-risk population (7). Currently, there is a very limited evidence for the use of biological and biosynthetic meshes in strangulated hernias in either open or laparo-endoscopic repair. Finally, there is an urgent need to start with randomized controlled comparative trials as well as to support registries with data to achieve more knowledge for tailored indication for the use of biological meshes.

  8. A new parallelization scheme for adaptive mesh refinement

    DOE PAGES

    Loffler, Frank; Cao, Zhoujian; Brandt, Steven R.; ...

    2016-05-06

    Here, we present a new method for parallelization of adaptive mesh refinement called Concurrent Structured Adaptive Mesh Refinement (CSAMR). This new method offers the lower computational cost (i.e. wall time x processor count) of subcycling in time, but with the runtime performance (i.e. smaller wall time) of evolving all levels at once using the time step of the finest level (which does more work than subcycling but has less parallelism). We demonstrate our algorithm's effectiveness using an adaptive mesh refinement code, AMSS-NCKU, and show performance on Blue Waters and other high performance clusters. For the class of problem considered inmore » this paper, our algorithm achieves a speedup of 1.7-1.9 when the processor count for a given AMR run is doubled, consistent with our theoretical predictions.« less

  9. A new parallelization scheme for adaptive mesh refinement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loffler, Frank; Cao, Zhoujian; Brandt, Steven R.

    Here, we present a new method for parallelization of adaptive mesh refinement called Concurrent Structured Adaptive Mesh Refinement (CSAMR). This new method offers the lower computational cost (i.e. wall time x processor count) of subcycling in time, but with the runtime performance (i.e. smaller wall time) of evolving all levels at once using the time step of the finest level (which does more work than subcycling but has less parallelism). We demonstrate our algorithm's effectiveness using an adaptive mesh refinement code, AMSS-NCKU, and show performance on Blue Waters and other high performance clusters. For the class of problem considered inmore » this paper, our algorithm achieves a speedup of 1.7-1.9 when the processor count for a given AMR run is doubled, consistent with our theoretical predictions.« less

  10. Characterization of the Mechanical Strength, Resorption Properties, and Histologic Characteristics of a Fully Absorbable Material (Poly-4-hydroxybutyrate—PHASIX Mesh) in a Porcine Model of Hernia Repair

    PubMed Central

    Deeken, Corey R.; Matthews, Brent D.

    2013-01-01

    Purpose. Poly-4-hydroxybutyrate (P4HB) is a naturally derived, absorbable polymer. P4HB has been manufactured into PHASIX Mesh and P4HB Plug designs for soft tissue repair. The objective of this study was to evaluate mechanical strength, resorption properties, and histologic characteristics in a porcine model. Methods. Bilateral defects were created in the abdominal wall of n = 20 Yucatan minipigs and repaired in a bridged fashion with PHASIX Mesh or P4HB Plug fixated with SorbaFix or permanent suture, respectively. Mechanical strength, resorption properties, and histologic characteristics were evaluated at 6, 12, 26, and 52 weeks (n = 5 each). Results. PHASIX Mesh and P4HB Plug repairs exhibited similar burst strength, stiffness, and molecular weight at all time points, with no significant differences detected between the two devices (P > 0.05). PHASIX Mesh and P4HB Plug repairs also demonstrated significantly greater burst strength and stiffness than native abdominal wall at all time points (P < 0.05), and material resorption increased significantly over time (P < 0.001). Inflammatory infiltrates were mononuclear, and both devices exhibited mild to moderate granulation tissue/vascularization. Conclusions. PHASIX Mesh and P4HB Plug demonstrated significant mechanical strength compared to native abdominal wall, despite significant material resorption over time. Histological assessment revealed a comparable mild inflammatory response and mild to moderate granulation tissue/vascularization. PMID:23781348

  11. 2017 update of the WSES guidelines for emergency repair of complicated abdominal wall hernias.

    PubMed

    Birindelli, Arianna; Sartelli, Massimo; Di Saverio, Salomone; Coccolini, Federico; Ansaloni, Luca; van Ramshorst, Gabrielle H; Campanelli, Giampiero; Khokha, Vladimir; Moore, Ernest E; Peitzman, Andrew; Velmahos, George; Moore, Frederick Alan; Leppaniemi, Ari; Burlew, Clay Cothren; Biffl, Walter L; Koike, Kaoru; Kluger, Yoram; Fraga, Gustavo P; Ordonez, Carlos A; Novello, Matteo; Agresta, Ferdinando; Sakakushev, Boris; Gerych, Igor; Wani, Imtiaz; Kelly, Michael D; Gomes, Carlos Augusto; Faro, Mario Paulo; Tarasconi, Antonio; Demetrashvili, Zaza; Lee, Jae Gil; Vettoretto, Nereo; Guercioni, Gianluca; Persiani, Roberto; Tranà, Cristian; Cui, Yunfeng; Kok, Kenneth Y Y; Ghnnam, Wagih M; Abbas, Ashraf El-Sayed; Sato, Norio; Marwah, Sanjay; Rangarajan, Muthukumaran; Ben-Ishay, Offir; Adesunkanmi, Abdul Rashid K; Lohse, Helmut Alfredo Segovia; Kenig, Jakub; Mandalà, Stefano; Coimbra, Raul; Bhangu, Aneel; Suggett, Nigel; Biondi, Antonio; Portolani, Nazario; Baiocchi, Gianluca; Kirkpatrick, Andrew W; Scibé, Rodolfo; Sugrue, Michael; Chiara, Osvaldo; Catena, Fausto

    2017-01-01

    Emergency repair of complicated abdominal wall hernias may be associated with worsen outcome and a significant rate of postoperative complications. There is no consensus on management of complicated abdominal hernias. The main matter of debate is about the use of mesh in case of intestinal resection and the type of mesh to be used. Wound infection is the most common complication encountered and represents an immense burden especially in the presence of a mesh. The recurrence rate is an important topic that influences the final outcome. A World Society of Emergency Surgery (WSES) Consensus Conference was held in Bergamo in July 2013 with the aim to define recommendations for emergency repair of abdominal wall hernias in adults. This document represents the executive summary of the consensus conference approved by a WSES expert panel. In 2016, the guidelines have been revised and updated according to the most recent available literature.

  12. Sustainable wall construction and exterior insulation retrofit technology process and structure

    DOEpatents

    Vohra, Arun

    2000-01-01

    A low-cost process for exterior wall insulation retrofit, or new wall construction by stacking layers of fabric tube filled with insulating material against a wall and covering them with mesh and stucco provides a durable structure with good insulating value.

  13. Long-term anisotropic mechanical response of surgical meshes used to repair abdominal wall defects.

    PubMed

    Hernández-Gascón, B; Peña, E; Pascual, G; Rodríguez, M; Bellón, J M; Calvo, B

    2012-01-01

    Routine hernia repair surgery involves the implant of synthetic mesh. However, this type of procedure may give rise to pain and bowel incarceration and strangulation, causing considerable patient disability. The purpose of this study was to compare the long-term behaviour of three commercial meshes used to repair the partially herniated abdomen in New Zealand White rabbits: the heavyweight (HW) mesh, Surgipro(®) and lightweight (LW) mesh, Optilene(®), both made of polypropylene (PP), and a mediumweight (MW) mesh, Infinit(®), made of polytetrafluoroethylene (PTFE). The implanted meshes were mechanical and histological assessed at 14, 90 and 180 days post-implant. This behaviour was compared to the anisotropic mechanical behaviour of the unrepaired abdominal wall in control non-operated rabbits. Both uniaxial mechanical tests conducted in craneo-caudal and perpendicular directions and histological findings revealed substantial collagen growth over the repaired hernial defects causing stiffness in the repair zone, and thus a change in the original properties of the meshes. The mechanical behaviour of the healthy tissue in the craneo-caudal direction was not reproduced by any of the implanted meshes after 14 days or 90 days of implant, whereas in the perpendicular direction, SUR and OPT achieved similar behaviour. From a mechanical standpoint, the anisotropic PP-lightweight meshes may be considered a good choice in the long run, which correlates with the structure of the regenerated tissue. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Development of new anatomy reconstruction software to localize cardiac isochrones to the cardiac surface from the 12 lead ECG.

    PubMed

    van Dam, Peter M; Gordon, Jeffrey P; Laks, Michael M; Boyle, Noel G

    2015-01-01

    Non-invasive electrocardiographic imaging (ECGI) of the cardiac muscle can help the pre-procedure planning of the ablation of ventricular arrhythmias by reducing the time to localize the origin. Our non-invasive ECGI system, the cardiac isochrone positioning system (CIPS), requires non-intersecting meshes of the heart, lungs and torso. However, software to reconstruct the meshes of the heart, lungs and torso with the capability to check and prevent these intersections is currently lacking. Consequently the reconstruction of a patient specific model with realistic atrial and ventricular wall thickness and incorporating blood cavities, lungs and torso usually requires additional several days of manual work. Therefore new software was developed that checks and prevents any intersections, and thus enables the use of accurate reconstructed anatomical models within CIPS. In this preliminary study we investigated the accuracy of the created patient specific anatomical models from MRI or CT. During the manual segmentation of the MRI data the boundaries of the relevant tissues are determined. The resulting contour lines are used to automatically morph reference meshes of the heart, lungs or torso to match the boundaries of the morphed tissue. Five patients were included in the study; models of the heart, lungs and torso were reconstructed from standard cardiac MRI images. The accuracy was determined by computing the distance between the segmentation contours and the morphed meshes. The average accuracy of the reconstructed cardiac geometry was within 2mm with respect to the manual segmentation contours on the MRI images. Derived wall volumes and left ventricular wall thickness were within the range reported in literature. For each reconstructed heart model the anatomical heart axis was computed using the automatically determined anatomical landmarks of the left apex and the mitral valve. The accuracy of the reconstructed heart models was well within the accuracy of the used medical image data (pixel size <1.5mm). For the lungs and torso the number of triangles in the mesh was reduced, thus decreasing the accuracy of the reconstructed mesh. A novel software tool has been introduced, which is able to reconstruct accurate cardiac anatomical models from MRI or CT within only a few hours. This new anatomical reconstruction tool might reduce the modeling errors within the cardiac isochrone positioning system and thus enable the clinical application of CIPS to localize the PVC/VT focus to the ventricular myocardium from only the standard 12 lead ECG. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Optical touch sensing: practical bounds for design and performance

    NASA Astrophysics Data System (ADS)

    Bläßle, Alexander; Janbek, Bebart; Liu, Lifeng; Nakamura, Kanna; Nolan, Kimberly; Paraschiv, Victor

    2013-02-01

    Touch sensitive screens are used in many applications ranging in size from smartphones and tablets to display walls and collaborative surfaces. In this study, we consider optical touch sensing, a technology best suited for large-scale touch surfaces. Optical touch sensing utilizes cameras and light sources placed along the edge of the display. Within this framework, we first find a sufficient number of cameras necessary for identifying a convex polygon touching the screen, using a continuous light source on the boundary of a circular domain. We then find the number of cameras necessary to distinguish between two circular objects in a circular or rectangular domain. Finally, we use Matlab to simulate the polygonal mesh formed from distributing cameras and light sources on a circular domain. Using this, we compute the number of polygons in the mesh and the maximum polygon area to give us information about the accuracy of the configuration. We close with summary and conclusions, and pointers to possible future research directions.

  16. Comparison of acellular dermal matrix and synthetic mesh for lateral chest wall reconstruction in a rabbit model.

    PubMed

    Holton, Luther H; Chung, Thomas; Silverman, Ronald P; Haerian, Hafez; Goldberg, Nelson H; Burrows, Whitney M; Gobin, Andrea; Butler, Charles E

    2007-04-01

    Synthetic mesh is used for chest wall reconstruction, but infection or exposure can occur and necessitate removal. Human acellular dermal matrix (AlloDerm) has been used to reconstruct musculofascial defects in the trunk with low infection and herniation rates. AlloDerm may have advantages over synthetic mesh for chest wall reconstruction. This study compared outcomes and repair strengths of AlloDerm to expanded polytetrafluoroethylene mesh used for repair of rib cage defects. A 3 x 3-cm, full-thickness, lateral rib cage defect was created in each rabbit and repaired with expanded polytetrafluoroethylene (n = 8) or acellular dermal matrix (n = 9). At 4 weeks, the animals were euthanized and evaluated for lung herniation/dehiscence, strength of adhesions between the implant and intrapleural structures, and breaking strength of the implant materials and the implant-fascia interface. Tissue sections were analyzed with histologic and immunohistochemical staining to evaluate cellular infiltration and vascularization. No herniation or dehiscence occurred with either material. The incidence and strength of adhesions was similar between materials. The mean breaking strength of the AlloDerm-fascia interface (14.5 +/- 8.9 N) was greater than the expanded polytetrafluoroethylene-fascia interface (8.7 +/- 4.4 N; p = 0.027) and similar to the rib-intercostal-rib interface of the contralateral native chest wall (14.0 +/- 5.6 N). The AlloDerm grafts became infiltrated with cells and vascularized after implantation. AlloDerm used for chest wall reconstruction results in greater implant-defect interface strength than expanded polytetrafluoroethylene. The ability of AlloDerm to become vascularized and remodeled by autologous cells and to resist infection may be advantageous for chest wall reconstruction.

  17. Changes in the frequencies of abdominal wall hernias and the preferences for their repair: a multicenter national study from Turkey.

    PubMed

    Seker, Gaye; Kulacoglu, Hakan; Öztuna, Derya; Topgül, Koray; Akyol, Cihangir; Çakmak, Atıl; Karateke, Faruk; Özdoğan, Mehmet; Ersoy, Eren; Gürer, Ahmet; Zerbaliyev, Elbrus; Seker, Duray; Yorgancı, Kaya; Pergel, Ahmet; Aydın, Ibrahim; Ensari, Cemal; Bilecik, Tuna; Kahraman, İzzettin; Reis, Erhan; Kalaycı, Murat; Canda, Aras Emre; Demirağ, Alp; Kesicioğlu, Tuğrul; Malazgirt, Zafer; Gündoğdu, Haldun; Terzi, Cem

    2014-01-01

    Abdominal wall hernias are a common problem in the general population. A Western estimate reveals that the lifetime risk of developing a hernia is about 2%. As a result, hernia repairs likely comprise the most frequent general surgery operations. More than 20 million hernias are estimated to be repaired every year around the world. Numerous repair techniques have been described to date however tension-free mesh repairs are widely used today because of their low hernia recurrence rates. Nevertheless, there are some ongoing debates regarding the ideal approach (open or laparoscopic), the ideal anesthesia (general, local, or regional), and the ideal mesh (standard polypropylene or newer meshes).

  18. Osteoradionecrosis of the chest wall. Management of postresection defects using Marlex mesh and a rotated latissimus dorsi myocutaneous flap

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hines, G.L.; Lee, G.

    1983-11-01

    Full thickness chest wall resection and single stage reconstruction for osteoradionecrosis of the chest wall was performed on five patients. All patients had undergone radical mastectomy and radiation therapy from 5 to 18 years prior to chest wall resection. Defects varied from 12 X 5 cm to 15 X 15 cm, and included from two to four ribs. Reconstruction was performed using Marlex mesh to reconstruct the bony thorax and a rotated latissimus dorsi myocutaneous flap. Coverage was successfully performed in all cases, and no patient experienced postoperative pulmonary dysfunction. There were no complications related to either the bony thoraxmore » reconstruction or the latissimus flap. The use of this technique has provided a safe, convenient, and reliable method of chest wall reconstruction.« less

  19. Hexahedral mesh generation via the dual arrangement of surfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitchell, S.A.; Tautges, T.J.

    1997-12-31

    Given a general three-dimensional geometry with a prescribed quadrilateral surface mesh, the authors consider the problem of constructing a hexahedral mesh of the geometry whose boundary is exactly the prescribed surface mesh. Due to the specialized topology of hexahedra, this problem is more difficult than the analogous one for tetrahedra. Folklore has maintained that a surface mesh must have a constrained structure in order for there to exist a compatible hexahedral mesh. However, they have proof that a surface mesh need only satisfy mild parity conditions, depending on the topology of the three-dimensional geometry, for there to exist a compatiblemore » hexahedral mesh. The proof is based on the realization that a hexahedral mesh is dual to an arrangement of surfaces, and the quadrilateral surface mesh is dual to the arrangement of curves bounding these surfaces. The proof is constructive and they are currently developing an algorithm called Whisker Weaving (WW) that mirrors the proof steps. Given the bounding curves, WW builds the topological structure of an arrangement of surfaces having those curves as its boundary. WW progresses in an advancing front manner. Certain local rules are applied to avoid structures that lead to poor mesh quality. Also, after the arrangement is constructed, additional surfaces are inserted to separate features, so e.g., no two hexahedra share more than one quadrilateral face. The algorithm has generated meshes for certain non-trivial problems, but is currently unreliable. The authors are exploring strategies for consistently selecting which portion of the surface arrangement to advance based on the existence proof. This should lead us to a robust algorithm for arbitrary geometries and surface meshes.« less

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nasehi Tehrani, J; Wang, J; McEwan, A

    Purpose: In this study, we developed and evaluated a method for predicting lung surface deformation vector fields (SDVFs) based on surrogate signals such as chest and abdomen motion at selected locations and spirometry measurements. Methods: A Patient-specific 3D triangular surface mesh of the lung region at end-expiration (EE) phase was obtained by threshold-based segmentation method. For each patient, a spirometer recorded the flow volume changes of the lungs; and 192 selected points at a regular spacing of 2cm X 2cm matrix points over a total area of 34cm X 24cm on the surface of chest and abdomen was used tomore » detect chest wall motions. Preprocessing techniques such as QR factorization with column pivoting (QRCP) were employed to remove redundant observations of the chest and abdominal area. To create a statistical model between the lung surface and the corresponding surrogate signals, we developed a predictive model based on canonical ridge regression (CRR). Two unique weighting vectors were selected for each vertex on the surface of the lung, and they were optimized during the training process using the all other phases of 4D-CT except the end-inspiration (EI) phase. These parameters were employed to predict the vertices locations of a testing data set, which was the EI phase of 4D-CT. Results: For ten lung cancer patients, the deformation vector field of each vertex of lung surface mesh was estimated from the external motion at selected positions on the chest wall surface plus spirometry measurements. The average estimation of 98th percentile of error was less than 1 mm (AP= 0.85, RL= 0.61, and SI= 0.82). Conclusion: The developed predictive model provides a non-invasive approach to derive lung boundary condition. Together with personalized biomechanical respiration modelling, the proposed model can be used to derive the lung tumor motion during radiation therapy accurately from non-invasive measurements.« less

  1. Accuracy and predictability in use of AO three-dimensionally preformed titanium mesh plates for posttraumatic orbital reconstruction: a pilot study.

    PubMed

    Scolozzi, Paolo; Momjian, Armen; Heuberger, Joris; Andersen, Elene; Broome, Martin; Terzic, Andrej; Jaques, Bertrand

    2009-07-01

    The aim of this study was to prospectively evaluate the accuracy and predictability of new three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction.We analyzed the preoperative and postoperative clinical and radiologic data of 10 patients with isolated blow-out orbital fractures. Fracture locations were as follows: floor (N = 7; 70%), medial wall (N = 1; 1%), and floor/medial wall (N = 2; 2%). The floor fractures were exposed by a standard transconjunctival approach, whereas a combined transcaruncular transconjunctival approach was used in patients with medial wall fractures. A three-dimensional preformed AO titanium mesh plate (0.4 mm in thickness) was selected according to the size of the defect previously measured on the preoperative computed tomographic (CT) scan examination and fixed at the inferior orbital rim with 1 or 2 screws. The accuracy of plate positioning of the reconstructed orbit was assessed on the postoperative CT scan. Coronal CT scan slices were used to measure bony orbital volume using OsiriX Medical Image software. Reconstructed versus uninjured orbital volume were statistically correlated.Nine patients (90%) had a successful treatment outcome without complications. One patient (10%) developed a mechanical limitation of upward gaze with a resulting handicapping diplopia requiring hardware removal. Postoperative orbital CT scan showed an anatomic three-dimensional placement of the orbital mesh plates in all of the patients. Volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 2.5 cm(3). There was no significant difference in volume between the reconstructed and uninjured orbits.This preliminary study has demonstrated that three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction results in (1) a high rate of success with an acceptable rate of major clinical complications (10%) and (2) an anatomic restoration of the bony orbital contour and volume that closely approximates that of the contralateral uninjured orbit.

  2. Outcomes of abdominal wall reconstruction with acellular dermal matrix are not affected by wound contamination.

    PubMed

    Garvey, Patrick B; Martinez, Roberto A; Baumann, Donald P; Liu, Jun; Butler, Charles E

    2014-11-01

    The optimal type of mesh for complex abdominal wall reconstruction has not been elucidated. We hypothesized that AWRs using acellular dermal matrix (ADM) experience low rates of surgical site occurrence (SSO) and surgical site infection, despite increasing degrees of wound contamination. We retrospectively reviewed prospectively collected data from consecutive abdominal wall reconstructions with ADM over a 9-year period. Outcomes of abdominal wall reconstructions were compared between patients with different CDC wound classifications. Univariate and multivariate logistic regression and Cox proportional hazard regression analyses identified potential associations and predictive/protective factors. The 359 patients had a mean follow-up of 28.3 ± 19.0 months. Reconstruction of clean wounds (n = 171) required fewer reoperations than that of combined contaminated (n = 188) wounds (2.3% vs 11.2%; p = 0.001) and trended toward experiencing fewer SSOs (19.9% vs 28.7%, p = 0.052). There were no significant differences between clean and combined contaminated cases in 30-day SSI (8.8% vs 8.0%), hernia recurrence (9.9% vs 10.1%), and mesh removal (1.2% vs 1.1%) rates. Independent predictors of SSO included body mass index ≥30 kg/m(2) (odds ratio [OR] 3.6; p < 0.001), 1 or more comorbidities (OR 2.5; p = 0.008), and defect width ≥15 cm (OR 1.8; p = 0.02). Complex abdominal wall reconstructions using ADM demonstrated similar rates of complications between the different CDC wound classifications. This is in contradistinction to published outcomes for abdominal wall reconstruction using synthetic mesh that show progressively higher complication rates with increasing degrees of contamination. These data support the use of ADM rather than synthetic mesh for complex abdominal wall reconstruction in the setting of wound contamination. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Biomechanical analyses of mesh fixation in TAPP and TEP hernia repair.

    PubMed

    Schwab, R; Schumacher, O; Junge, K; Binnebösel, M; Klinge, U; Becker, H P; Schumpelick, V

    2008-03-01

    Reliable laparoscopic fixation of meshes prior to their fibrous incorporation is intended to minimize recurrences following transabdominal preperitoneal hernia repair (TAPP) and totally extraperitoneal repair (TEP) repair of inguinal hernias. However, suture-, tack- and staple-based fixation systems are associated with postoperative chronic inguinal pain. Initial fixation with fibrin sealant offers an atraumatic alternative, but there is little data demonstrating directly whether fibrin-based mesh adhesion provides adequate biomechanical stability for repair of inguinal hernia by TAPP and TEP. Using a newly developed, standardized simulation model for abdominal wall hernias, sublay repairs were performed with six different types of commercially available hernia mesh. The biomechanical stability achieved, and the protection afforded by the mesh-hernia overlap, were compared for three different techniques: nonfixation, point-by-point suture fixation, and fibrin sealant fixation. Mesh dislocation from the repaired hernia defect was consistently seen with nonfixation. This was reliably prevented with all six mesh types when fixed using either sutures or fibrin sealant. The highest stress resistance across the whole abdominal wall was found following superficial fixation with fibrin sealant across the mesh types. There was a highly statistically significant improvement in fixation stability with fibrin sealant versus fixation using eight single sutures (p = 0.008), as assessed by the range of achievable peak pressure stress up to 200 mmHg. To ensure long-term freedom from recurrence, intraoperative mesh-hernia overlap must be retained. This can be achieved with fibrin sealant up to the incorporation of the mesh - without trauma and with biomechanical stability.

  4. Transvaginal single-incision mesh reconstruction for recurrent or advanced anterior vaginal wall prolapse.

    PubMed

    Marschke, J; Hengst, L; Schwertner-Tiepelmann, N; Beilecke, K; Tunn, R

    2015-05-01

    Single-incision transvaginal mesh for reconstruction of Level I and II prolapses in women with recurrent or advanced prolapse. We evaluated functional, anatomical, sonomorphological and quality-of-life outcome. Data were collected retrospectively for preoperative parameters and at follow-up visits. Anatomical cure was assessed with vaginal examination using the ICS-POP-Q system; introital-ultrasound scan for postvoidal residual and description of mesh characteristics was performed. We applied a visual analogue scale (VAS) and the German Pelvic Floor Questionnaire to assess quality-of-life. Seventy women with cystocele (III: 61.3%/IV: 16%), all post-hysterectomy and in majority (81.4%) after previous cystocele repair, were operated using a single-incision transvaginal technique. Overall anatomical success rate was 95.7% with significant improvement in quality-of-life (p < 0.0001). Mesh erosion occurred in 5.7%, one patient presented symptomatic vaginal vault prolapse. Postvoidal residual declined significantly (58 vs. 2.9%). Sonographic mesh length was 55.7% of implanted mesh with a wide range of mesh position, but no signs of mesh dislocation. There was no de novo dyspareunia reported, one case of preoperative existing dyspareunia worsened. No severe adverse event was observed. We hereby present a trial of a high-risk group of patients requiring reconstruction of anterior and apical vaginal wall in mostly recurrent prolapse situation. Our data support the hypothesis of improved anatomical and functional results and less mesh shrinkage caused by the single-incision technique with fixation in sacrospinous ligament in combination with modification in mesh quality compared to former multi-incision techniques.

  5. Intraperitoneal onlay mesh reinforcement of the abdominal wall: a new surgical option for treatment of anterior cutaneous nerve entrapment syndrome-a retrospective cohort analysis of 30 consecutive patients.

    PubMed

    Stirler, Vincent M A; Raymakers, Johan T F J; Rakic, Srdjan

    2016-07-01

    The aim of the study was to introduce a new surgical treatment for anterior cutaneous nerve entrapment syndrome, a frequently unrecognised disorder in the general population responsible for chronic abdominal wall pain with limited treatment options to date. We hypothesised that intraperitoneal onlay mesh reinforcement could dissipate excessive increases in intra-abdominal pressure and prevent entrapment of the neurovascular bundle. Retrospective cohort analysis was performed between September 2002 and March 2014. All consecutive patients diagnosed with anterior cutaneous nerve entrapment syndrome refractory to conservative treatment (n = 30) underwent laparoscopic intraperitoneal onlay mesh reinforcement of the painful area in the abdominal wall. Planned follow-up took place at 2, 6 and 12 weeks after surgery and at time of analysis (March 2015). Primary outcome was patients' satisfaction after treatment at short and long term (last follow-up) using a verbal rating score as measurement (1 = I am very satisfied; I never experience pain, 2 = I am satisfied; I occasionally experience some pain, 3 = I have improved but experience pain on a regular basis, 4 = I have had no result on this treatment, 5 = my pain is worse after treatment). Scores 1 and 2 were classified as success, and scores 4 and 5 as failure of the treatment. Thirty patients underwent laparoscopic intraperitoneal onlay mesh reinforcement. None were lost to follow-up (mean 54 ± 44 months, range 12-122, median 38). Short- and long-term success rates were 90 and 71 %, respectfully. Intraperitoneal onlay mesh reinforcement of the abdominal wall seems to be a promising option for the treatment of intractable anterior cutaneous nerve entrapment syndrome.

  6. An ODE-Based Wall Model for Turbulent Flow Simulations

    NASA Technical Reports Server (NTRS)

    Berger, Marsha J.; Aftosmis, Michael J.

    2017-01-01

    Fully automated meshing for Reynolds-Averaged Navier-Stokes Simulations, Mesh generation for complex geometry continues to be the biggest bottleneck in the RANS simulation process; Fully automated Cartesian methods routinely used for inviscid simulations about arbitrarily complex geometry; These methods lack of an obvious & robust way to achieve near wall anisotropy; Goal: Extend these methods for RANS simulation without sacrificing automation, at an affordable cost; Note: Nothing here is limited to Cartesian methods, and much becomes simpler in a body-fitted setting.

  7. A novel approach to mesh revision after sacrocolpopexy.

    PubMed

    Dawson, Melissa L; Rebecca, Rinko; Shah, Nima M; Whitmore, Kristene E

    2016-01-01

    Pelvic organ prolapse (POP) is the herniation of pelvic organs to or beyond the vaginal walls. POP affects 50% of parous women; of those women, 11% will need surgery based on bothersome symptoms. Transvaginal mesh has been used for vaginal augmentation since the 1990s. Complications from mesh use are now more prominent, and include chronic pelvic pain, dyspareunia, vaginal mesh erosion, and urinary and defecatory dysfunction. Presently, there is no consensus regarding treatment of these complications. Reported herein are two cases of women with defecatory dysfunction and pain after sacrocolpopexy who underwent mesh revision procedures performed with both urogynecologic and colorectal surgery.

  8. Magnetic Shielding of the Acceleration Channel Walls in a Long-Life Hall Thruster

    NASA Technical Reports Server (NTRS)

    Mikellides, Ioannis G.; Katz, Ira; Hofer, Richard R.; Goebel, Dan M.; de Grys, Kristi; Mathers, Alex

    2010-01-01

    In a Qualification Life Test (QLT) of the BPT-4000 Hall thruster that recently accumulated greater than 10,000 h it was found that the erosion of the acceleration channel practically stopped after approximately 5,600 h. Numerical simulations of this thruster using a 2-D axisymmetric, magnetic field-aligned-mesh (MFAM) plasma solver reveal that the process that led to this significant reduction of the erosion was multifaceted. It is found that when the channel receded from its early-in-life geometry to its steady-state configuration several changes in the near-wall plasma and sheath were induced by the magnetic field that, collectively, constituted an effective shielding of the walls from any significant ion bombardment. Because all such changes in the behavior of the ionized gas near the eroding surfaces were caused by the topology of the magnetic field there, we term this process "magnetic shielding."

  9. EFFECTS OF ETHYLENE OXIDE RESTERILISATION AND IN-VITRO DEGRADATION ON MECHANICAL PROPERTIES OF PARTIALLY ABSORBABLE COMPOSITE HERNIA MESHES.

    PubMed

    Endogan, T; Ozyaylali, I; Kulacoglu, H; Serbetci, K; Kiyak, G; Hasirci, N

    2013-06-01

    Prosthetic mesh repair for abdominal wall hernias is widely used because of its technical simplicity and low hernia recurrence rates. The most commonly used material is pure polypropylene mesh, however newer composite materials are recommended by some centers because of their advantages. However, these meshes are more expensive than pure polypropylene meshes. Resterilisation of a pure polypropylene mesh has been shown to be quite safe, and many centers prefer slicing a large mesh into smaller pieces that suitable for hernia type or defect size. Nevertheless there is no data about the safety after resterilisation of the composite meshes. To search the effects of resterilisation and In vitro degradation in phosphate buffered saline solution on the physical structure and the mechanical properties of partially absorbable lightweigth meshes. Laboratory-based research. Two composite meshes were used in the study: One mesh is consisted of monofilament polypropylene and monofilament polyglecaprone--a copolymer of glycolide and epsilon (ε)-caprolactone--(Ultrapro®, 28 g/m2, Ethicon, Hamburg, Germany),andthe otherone consisted of multifilamentpolypropyleneandmultifilament polyglactine (Vypro II®, 30 g/m2,Ethicon, Hamburg, Germany). Two large meshes were cut into rectangular specimens sized 50x20 mm for mechanical testing and 20x20 mm for In vitro degradation experiments. Meshes were divided into control group with no resterilisation and gas resterilisation. Ethylene oxide gas sterilisation was performed at 55°C for 4.5 hours. In vitro degradation in 0.01 M phosphate buffered saline (PBS, pH 7.4) solution at 37 ± 1°C for 8 weeks was applied to one subgroup in each mesh group. Tensiometric measurements and scanning electron microscopyic evaluations were completed for control and resterilisation specimens. Regardless of resterilisation, when meshes were exposed to In vitro degradation, all mechanical parameters decreased significantly. Highest reduction in mechanical properties was observed for Ultrapro due to the degradation of absorbable polyglecaprone and polyglactin parts of these meshes. It was observed that resterilisation by ethylene oxide did not have significant difference on the degradation characteristics and almost similar physical structures were observed for resterilised and non-resterilised meshes. For Vypro II meshes, no significant mechanical difference was observedbetweenresterilised andnon-resterilised meshes after degradationwhile resterilised Ultrapro meshes exhibited stronger characteristics than non-resterilised counterparts, after degradation. Resterilisation with ethylene oxide did not affect the mechanical properties of partially absorbable composite meshes. No important surface changeswere observed in scanning electron microscopy after resterilisation.

  10. Effects of ethylene oxide resterilization and in-vitro degradation on mechanical properties of partially absorbable composite hernia meshes.

    PubMed

    Endogan, T; Ozyaylali, I; Kulacoglu, H; Serbetci, K; Kiyak, G; Hasirci, N

    2013-01-01

    Prosthetic mesh repair for abdominal wall hernias is widely used because of its technical simplicity and low hernia recurrence rates. The most commonly used material is pure polypropylene mesh, although newer composite materials are recommended by some centers due to their advantages.However, these meshes are more expensive than pure polypropylene meshes. Resterilization of a pure polypropylene mesh has been shown to be quite safe, and many centers prefer slicing a large mesh into smaller pieces, suitable for any hernia type or defect size. Nevertheless there is no data about the safety after resterilization of the composite meshes. The present study was carried out to investigate the effects of resterilization and in vitro degradation in phosphate buffered saline solution on the physical structure and the mechanical properties of partially absorbable lightweight meshes. Two composite meshes were used in the study: One mesh consists of monofilament polypropylene and monofilament polyglecaprone -a copolymer of glycolide and epsilon(ε)- caprolactone - (Ultrapro®, 28 g m2, Ethicon, Hamburg,Germany), and the other one consisted of multifilament polypropylene and multifilament polyglactine (Vypro II®, 30g m2, Ethicon, Hamburg, Germany). Two large meshes were cut into rectangular specimens sized 50 x 20 mm for mechanical testing and 20 x 20 mm for in vitro degradation experiments.Meshes were divided into control group with no resterilization and gas resterilization. Ethylene oxide gas sterilization was performed at 55°C for 4.5 hours. In vitro degradation in 0.01M phosphate buffered saline (PBS, pH 7.4) solution at 37 ± 1°C for 8 weeks was applied to one subgroup in each mesh group. Tensiometric measurements and scanning electronmicroscopic evaluations were completed for control and resterilization specimens. Regardless of resterilization, when the meshes were exposed to in vitro degradation, all mechanical parameters decreased significantly. Highest reduction in mechanical properties was observed for Ultrapro due to the degradation of absorbable polyglecaprone and polyglactin parts of these meshes. It was observed that resterilization by ethylene oxide did not determine significant difference on the degradation characteristics and almost similar physical structures were observed for resterilized and non-resterilized meshes. For VyproII meshes, no significant mechanical difference was observed between resterilized and non-resterilized meshes after degradation while resterilized Ultrapro meshes exhibited stronger characteristics than non-resterilized counterparts, after degradation. Resterilization with ethylene oxide did not affect the mechanical properties of partially absorbable compositemeshes. No important surface changes were observed inscanning electron microscopy after resterilization. Celsius.

  11. The long-term behavior of lightweight and heavyweight meshes used to repair abdominal wall defects is determined by the host tissue repair process provoked by the mesh.

    PubMed

    Pascual, Gemma; Hernández-Gascón, Belén; Rodríguez, Marta; Sotomayor, Sandra; Peña, Estefania; Calvo, Begoña; Bellón, Juan M

    2012-11-01

    Although heavyweight (HW) or lightweight (LW) polypropylene (PP) meshes are widely used for hernia repair, other alternatives have recently appeared. They have the same large-pore structure yet are composed of polytetrafluoroethylene (PTFE). This study compares the long-term (3 and 6 months) behavior of meshes of different pore size (HW compared with LW) and composition (PP compared with PTFE). Partial defects were created in the lateral wall of the abdomen in New Zealand White rabbits and then repaired by the use of a HW or LW PP mesh or a new monofilament, large-pore PTFE mesh (Infinit). At 90 and 180 days after implantation, tissue incorporation, gene and protein expression of neocollagens (reverse transcription-polymerase chain reaction/immunofluorescence), macrophage response (immunohistochemistry), and biomechanical strength were determined. Shrinkage was measured at 90 days. All three meshes induced good host tissue ingrowth, yet the macrophage response was significantly greater in the PTFE implants (P < .05). Collagen 1/3 mRNA levels failed to vary at 90 days yet in the longer term, the LW meshes showed the reduced genetic expression of both collagens (P < .05) accompanied by increased neocollagen deposition, indicating more efficient mRNA translation. After 90-180 days of implant, tensile strengths and elastic modulus values were similar for all 3 implants (P > .05). Host collagen deposition is mesh pore size dependent whereas the macrophage response induced is composition dependent with a greater response shown by PTFE. In the long term, macroporous meshes show comparable biomechanical behavior regardless of their pore size or composition. Copyright © 2012 Mosby, Inc. All rights reserved.

  12. Structural differences and architectural features of two different polypropylene slings (TVT-O and I-STOP) have no impact on biocompatibility and tissue reactions

    PubMed Central

    Przydacz, Mikolaj; Adli, Oussama El Yazami; Mahfouz, Wally; Loutochin, Oleg; Bégin, Louis R.

    2017-01-01

    Introduction To evaluate the impact of design features of the synthetic mid-urethral slings on tissue integrity and inflammatory responses. Material and methods In total 30 female Sprague-Dawley rats were implanted with type I monofilamentous, macroporous polypropylene meshes: Gynecare TVT-Obturator tape® (Ethicon Inc., Johnson & Johnson, Somerville, NJ, USA) and I-STOP® (CL Medical Inc., Lyon, France). All animal groups were sacrificed at set time intervals – 6 weeks, 3 months, 6 months, 9 months and 12 months – and the abdominal wall was harvested with mesh strips for histological evaluation. Results All mesh strips appeared to be well incorporated into the abdominal wall, and no signs of shrinkage was noticed. All specimens showed a thin/delicate, loose, fibrous interface between the synthetic graft plate and abdominal wall, along with mild inflammatory reactions from 6 weeks to 12 months. Conclusions Both mesh brands induced comparable, minimal foreign body reactions and integrated well into the host tissues despite differences in architectural features. TVT-O® and I-STOP® evoked similar low-grade inflammatory responses up to 12 months in this animal model. Structural differences and architectural features of polypropylene slings used in this study have had no impact on tissue integrity and inflammatory responses. PMID:28721282

  13. Structural differences and architectural features of two different polypropylene slings (TVT-O and I-STOP) have no impact on biocompatibility and tissue reactions.

    PubMed

    Przydacz, Mikolaj; Adli, Oussama El Yazami; Mahfouz, Wally; Loutochin, Oleg; Bégin, Louis R; Corcos, Jacques

    2017-06-30

    To evaluate the impact of design features of the synthetic mid-urethral slings on tissue integrity and inflammatory responses. In total 30 female Sprague-Dawley rats were implanted with type I monofilamentous, macroporous polypropylene meshes: Gynecare TVT-Obturator tape ® (Ethicon Inc., Johnson & Johnson, Somerville, NJ, USA) and I-STOP ® (CL Medical Inc., Lyon, France). All animal groups were sacrificed at set time intervals - 6 weeks, 3 months, 6 months, 9 months and 12 months - and the abdominal wall was harvested with mesh strips for histological evaluation. All mesh strips appeared to be well incorporated into the abdominal wall, and no signs of shrinkage was noticed. All specimens showed a thin/delicate, loose, fibrous interface between the synthetic graft plate and abdominal wall, along with mild inflammatory reactions from 6 weeks to 12 months. Both mesh brands induced comparable, minimal foreign body reactions and integrated well into the host tissues despite differences in architectural features. TVT-O ® and I-STOP ® evoked similar low-grade inflammatory responses up to 12 months in this animal model. Structural differences and architectural features of polypropylene slings used in this study have had no impact on tissue integrity and inflammatory responses.

  14. Changes in the Frequencies of Abdominal Wall Hernias and the Preferences for Their Repair: A Multicenter National Study From Turkey

    PubMed Central

    Şeker, Gaye; Kulacoglu, Hakan; Öztuna, Derya; Topgül, Koray; Akyol, Cihangir; Çakmak, Atıl; Karateke, Faruk; Özdoğan, Mehmet; Ersoy, Eren; Gürer, Ahmet; Zerbaliyev, Elbrus; Seker, Duray; Yorgancı, Kaya; Pergel, Ahmet; Aydın, İbrahim; Ensari, Cemal; Bilecik, Tuna; Kahraman, İzzettin; Reis, Erhan; Kalaycı, Murat; Canda, Aras Emre; Demirağ, Alp; Kesicioğlu, Tuğrul; Malazgirt, Zafer; Gündoğdu, Haldun; Terzi, Cem

    2014-01-01

    Abdominal wall hernias are a common problem in the general population. A Western estimate reveals that the lifetime risk of developing a hernia is about 2%.1–3 As a result, hernia repairs likely comprise the most frequent general surgery operations. More than 20 million hernias are estimated to be repaired every year around the world.4 Numerous repair techniques have been described to date however tension-free mesh repairs are widely used today because of their low hernia recurrence rates. Nevertheless, there are some ongoing debates regarding the ideal approach (open or laparoscopic),5,6 the ideal anesthesia (general, local, or regional),7,8 and the ideal mesh (standard polypropylene or newer meshes).9,10 PMID:25216417

  15. Minimizing donor-site morbidity following bilateral pedicled TRAM breast reconstruction with the double mesh fold over technique.

    PubMed

    Bharti, Gaurav; Groves, Leslie; Sanger, Claire; Thompson, James; David, Lisa; Marks, Malcolm

    2013-05-01

    Transverse rectus abdominus muscle flaps (TRAM) can result in significant abdominal wall donor-site morbidity. We present our experience with bilateral pedicle TRAM breast reconstruction using a double-layered polypropylene mesh fold over technique to repair the rectus fascia. A retrospective study was performed that included patients with bilateral pedicle TRAM breast reconstruction and abdominal reconstruction using a double-layered polypropylene mesh fold over technique. Thirty-five patients met the study criteria with a mean age of 49 years old and mean follow-up of 7.4 years. There were no instances of abdominal hernia and only 2 cases (5.7%) of abdominal bulge. Other abdominal complications included partial umbilical necrosis (14.3%), seroma (11.4%), partial wound dehiscence (8.6%), abdominal weakness (5.7%), abdominal laxity (2.9%), and hematoma (2.9%). The TRAM flap is a reliable option for bilateral autologous breast reconstruction. Using the double mesh repair of the abdominal wall can reduce instances of an abdominal bulge and hernia.

  16. The integration of a mesh reflector to a 15-foot box truss structure. Task 3: Box truss analysis and technology development

    NASA Technical Reports Server (NTRS)

    Bachtell, E. E.; Thiemet, W. F.; Morosow, G.

    1987-01-01

    To demonstrate the design and integration of a reflective mesh surface to a deployable truss structure, a mesh reflector was installed on a 15 foot box truss cube. The specific features demonstrated include: (1) sewing seams in reflective mesh; (2) mesh stretching to desired preload; (3) installation of surface tie cords; (4) installation of reflective surface on truss; (5) setting of reflective surface; (6) verification of surface shape/accuracy; (7) storage and deployment; (8) repeatability of reflector surface; and (9) comparison of surface with predicted shape using analytical methods developed under a previous task.

  17. Method of generating a surface mesh

    DOEpatents

    Shepherd, Jason F [Albuquerque, NM; Benzley, Steven [Provo, UT; Grover, Benjamin T [Tracy, CA

    2008-03-04

    A method and machine-readable medium provide a technique to generate and modify a quadrilateral finite element surface mesh using dual creation and modification. After generating a dual of a surface (mesh), a predetermined algorithm may be followed to generate and modify a surface mesh of quadrilateral elements. The predetermined algorithm may include the steps of generating two-dimensional cell regions in dual space, determining existing nodes in primal space, generating new nodes in the dual space, and connecting nodes to form the quadrilateral elements (faces) for the generated and modifiable surface mesh.

  18. Local-Scale Simulations of Nucleate Boiling on Micrometer Featured Surfaces: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sitaraman, Hariswaran; Moreno, Gilberto; Narumanchi, Sreekant V

    2017-08-03

    A high-fidelity computational fluid dynamics (CFD)-based model for bubble nucleation of the refrigerant HFE7100 on micrometer-featured surfaces is presented in this work. The single-fluid incompressible Navier-Stokes equations, along with energy transport and natural convection effects are solved on a featured surface resolved grid. An a priori cavity detection method is employed to convert raw profilometer data of a surface into well-defined cavities. The cavity information and surface morphology are represented in the CFD model by geometric mesh deformations. Surface morphology is observed to initiate buoyancy-driven convection in the liquid phase, which in turn results in faster nucleation of cavities. Simulationsmore » pertaining to a generic rough surface show a trend where smaller size cavities nucleate with higher wall superheat. This local-scale model will serve as a self-consistent connection to larger device scale continuum models where local feature representation is not possible.« less

  19. Local-Scale Simulations of Nucleate Boiling on Micrometer-Featured Surfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sitaraman, Hariswaran; Moreno, Gilberto; Narumanchi, Sreekant V

    2017-07-12

    A high-fidelity computational fluid dynamics (CFD)-based model for bubble nucleation of the refrigerant HFE7100 on micrometer-featured surfaces is presented in this work. The single-fluid incompressible Navier-Stokes equations, along with energy transport and natural convection effects are solved on a featured surface resolved grid. An a priori cavity detection method is employed to convert raw profilometer data of a surface into well-defined cavities. The cavity information and surface morphology are represented in the CFD model by geometric mesh deformations. Surface morphology is observed to initiate buoyancy-driven convection in the liquid phase, which in turn results in faster nucleation of cavities. Simulationsmore » pertaining to a generic rough surface show a trend where smaller size cavities nucleate with higher wall superheat. This local-scale model will serve as a self-consistent connection to larger device scale continuum models where local feature representation is not possible.« less

  20. 8. Interior view at midsection shows columns and walls. Wire ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. Interior view at mid-section shows columns and walls. Wire mesh divides storage space. - Puget Sound Naval Shipyard, Munitions Storage Bunker, Naval Ammunitions Depot, South of Campbell Trail, Bremerton, Kitsap County, WA

  1. Numerical aspects and implementation of a two-layer zonal wall model for LES of compressible turbulent flows on unstructured meshes

    NASA Astrophysics Data System (ADS)

    Park, George Ilhwan; Moin, Parviz

    2016-01-01

    This paper focuses on numerical and practical aspects associated with a parallel implementation of a two-layer zonal wall model for large-eddy simulation (LES) of compressible wall-bounded turbulent flows on unstructured meshes. A zonal wall model based on the solution of unsteady three-dimensional Reynolds-averaged Navier-Stokes (RANS) equations on a separate near-wall grid is implemented in an unstructured, cell-centered finite-volume LES solver. The main challenge in its implementation is to couple two parallel, unstructured flow solvers for efficient boundary data communication and simultaneous time integrations. A coupling strategy with good load balancing and low processors underutilization is identified. Face mapping and interpolation procedures at the coupling interface are explained in detail. The method of manufactured solution is used for verifying the correct implementation of solver coupling, and parallel performance of the combined wall-modeled LES (WMLES) solver is investigated. The method has successfully been applied to several attached and separated flows, including a transitional flow over a flat plate and a separated flow over an airfoil at an angle of attack.

  2. Texture analysis improves level set segmentation of the anterior abdominal wall

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Zhoubing; Allen, Wade M.; Baucom, Rebeccah B.

    2013-12-15

    Purpose: The treatment of ventral hernias (VH) has been a challenging problem for medical care. Repair of these hernias is fraught with failure; recurrence rates ranging from 24% to 43% have been reported, even with the use of biocompatible mesh. Currently, computed tomography (CT) is used to guide intervention through expert, but qualitative, clinical judgments, notably, quantitative metrics based on image-processing are not used. The authors propose that image segmentation methods to capture the three-dimensional structure of the abdominal wall and its abnormalities will provide a foundation on which to measure geometric properties of hernias and surrounding tissues and, therefore,more » to optimize intervention.Methods: In this study with 20 clinically acquired CT scans on postoperative patients, the authors demonstrated a novel approach to geometric classification of the abdominal. The authors’ approach uses a texture analysis based on Gabor filters to extract feature vectors and follows a fuzzy c-means clustering method to estimate voxelwise probability memberships for eight clusters. The memberships estimated from the texture analysis are helpful to identify anatomical structures with inhomogeneous intensities. The membership was used to guide the level set evolution, as well as to derive an initial start close to the abdominal wall.Results: Segmentation results on abdominal walls were both quantitatively and qualitatively validated with surface errors based on manually labeled ground truth. Using texture, mean surface errors for the outer surface of the abdominal wall were less than 2 mm, with 91% of the outer surface less than 5 mm away from the manual tracings; errors were significantly greater (2–5 mm) for methods that did not use the texture.Conclusions: The authors’ approach establishes a baseline for characterizing the abdominal wall for improving VH care. Inherent texture patterns in CT scans are helpful to the tissue classification, and texture analysis can improve the level set segmentation around the abdominal region.« less

  3. The sensitivity of biological finite element models to the resolution of surface geometry: a case study of crocodilian crania

    PubMed Central

    Evans, Alistair R.; McHenry, Colin R.

    2015-01-01

    The reliability of finite element analysis (FEA) in biomechanical investigations depends upon understanding the influence of model assumptions. In producing finite element models, surface mesh resolution is influenced by the resolution of input geometry, and influences the resolution of the ensuing solid mesh used for numerical analysis. Despite a large number of studies incorporating sensitivity studies of the effects of solid mesh resolution there has not yet been any investigation into the effect of surface mesh resolution upon results in a comparative context. Here we use a dataset of crocodile crania to examine the effects of surface resolution on FEA results in a comparative context. Seven high-resolution surface meshes were each down-sampled to varying degrees while keeping the resulting number of solid elements constant. These models were then subjected to bite and shake load cases using finite element analysis. The results show that incremental decreases in surface resolution can result in fluctuations in strain magnitudes, but that it is possible to obtain stable results using lower resolution surface in a comparative FEA study. As surface mesh resolution links input geometry with the resulting solid mesh, the implication of these results is that low resolution input geometry and solid meshes may provide valid results in a comparative context. PMID:26056620

  4. Method for generating a mesh representation of a region characterized by a trunk and a branch thereon

    DOEpatents

    Shepherd, Jason [Albuquerque, NM; Mitchell, Scott A [Albuquerque, NM; Jankovich, Steven R [Anaheim, CA; Benzley, Steven E [Provo, UT

    2007-05-15

    The present invention provides a meshing method, called grafting, that lifts the prior art constraint on abutting surfaces, including surfaces that are linking, source/target, or other types of surfaces of the trunk volume. The grafting method locally modifies the structured mesh of the linking surfaces allowing the mesh to conform to additional surface features. Thus, the grafting method can provide a transition between multiple sweep directions extending sweeping algorithms to 23/4-D solids. The method is also suitable for use with non-sweepable volumes; the method provides a transition between meshes generated by methods other than sweeping as well.

  5. FASH and MASH: female and male adult human phantoms based on polygon mesh surfaces: I. Development of the anatomy

    NASA Astrophysics Data System (ADS)

    Cassola, V. F.; de Melo Lima, V. J.; Kramer, R.; Khoury, H. J.

    2010-01-01

    Among computational models, voxel phantoms based on computer tomographic (CT), nuclear magnetic resonance (NMR) or colour photographic images of patients, volunteers or cadavers have become popular in recent years. Although being true to nature representations of scanned individuals, voxel phantoms have limitations, especially when walled organs have to be segmented or when volumes of organs or body tissues, like adipose, have to be changed. Additionally, the scanning of patients or volunteers is usually made in supine position, which causes a shift of internal organs towards the ribcage, a compression of the lungs and a reduction of the sagittal diameter especially in the abdominal region compared to the regular anatomy of a person in the upright position, which in turn can influence organ and tissue absorbed or equivalent dose estimates. This study applies tools developed recently in the areas of computer graphics and animated films to the creation and modelling of 3D human organs, tissues, skeletons and bodies based on polygon mesh surfaces. Female and male adult human phantoms, called FASH (Female Adult meSH) and MASH (Male Adult meSH), have been designed using software, such as MakeHuman, Blender, Binvox and ImageJ, based on anatomical atlases, observing at the same time organ masses recommended by the International Commission on Radiological Protection for the male and female reference adult in report no 89. 113 organs, bones and tissues have been modelled in the FASH and the MASH phantoms representing locations for adults in standing posture. Most organ and tissue masses of the voxelized versions agree with corresponding data from ICRP89 within a margin of 2.6%. Comparison with the mesh-based male RPI_AM and female RPI_AF phantoms shows differences with respect to the material used, to the software and concepts applied, and to the anatomies created.

  6. Technique for converting non-conforming hexahedral-to-hexahedral interfaces into conforming interfaces

    DOEpatents

    Staten, Matthew L.; Shepherd, Jason F.; Ledoux, Frank; Shimada, Kenji; Merkley, Karl G.; Carbonera, Carlos

    2013-03-05

    A technique for conforming an interface between a first mesh and a second mesh is disclosed. A first interface surface in the first mesh and a second interface surface in the second mesh residing along the interface are identified. The first and second interface surfaces are initially non-conforming along the interface. Chords within the first and second interface surfaces that fall within a threshold separation distance of each other are paired. Sheets having chords that reside within the first or second interface surfaces are recursively inserted into or extracted from one or both of the first and second meshes until all remaining chords within the first interface surface are paired with corresponding chords in the second interface surface and all remaining chords within the second interface surface are paired with corresponding chords in the first interface surface.

  7. Study of factors governing oil-water separation process using TiO₂ films prepared by spray deposition of nanoparticle dispersions.

    PubMed

    Gondal, Mohammed A; Sadullah, Muhammad S; Dastageer, Mohamed A; McKinley, Gareth H; Panchanathan, Divya; Varanasi, Kripa K

    2014-08-27

    Surfaces which possess extraordinary water attraction or repellency depend on surface energy, surface chemistry, and nano- and microscale surface roughness. Synergistic superhydrophilic-underwater superoleophobic surfaces were fabricated by spray deposition of nanostructured TiO2 on stainless steel mesh substrates. The coated meshes were then used to study gravity driven oil-water separation, where only the water from the oil-water mixture is allowed to permeate through the mesh. Oil-water separation efficiencies of up to 99% could be achieved through the coated mesh of pore sizes 50 and 100 μm, compared to no separation at all, that was observed in the case of uncoated meshes of the same material and pore sizes. An adsorbed water on the TiO2 coated surface, formation of a water-film between the wires that form the mesh and the underwater superoleophobicity of the structured surface are the key factors that contribute to the enhanced efficiency observed in oil-water separation. The nature of the oil-water separation process using this coated mesh (in which the mesh allows water to pass through the porous structure but resists wetting by the oil phase) minimizes the fouling of mesh so that the need for frequent replacement of the separating medium is reduced. The fabrication approach presented here can be applied for coating large surface areas and to develop a large-scale oil-water separation facility for oil-field applications and petroleum industries.

  8. Simulation of RCC Crack Growth Due to Carbon Oxidation in High-Temperature Gas Environments

    NASA Technical Reports Server (NTRS)

    Titov, E. V.; Levin, D. A.; Picetti, Donald J.; Anderson, Brian P.

    2009-01-01

    The carbon wall oxidation technique coupled with a CFD technique was employed to study the flow in the expanding crack channel caused by the oxidation of the channel carbon walls. The recessing 3D surface morphing procedure was developed and tested in comparison with the arcjet experimental results. The multi-block structured adaptive meshing was used to model the computational domain changes due to the wall recession. Wall regression rates for a reinforced carbon-carbon (RCC) samples, that were tested in a high enthalpy arcjet environment, were computationally obtained and used to assess the channel expansion. The test geometry and flow conditions render the flow regime as the transitional to continuum, therefore Navier-Stokes gas dynamic approach with the temperature jump and velocity slip correction to the boundary conditions was used. The modeled mechanism for wall material loss was atomic oxygen reaction with bare carbon. The predicted channel growth was found to agree with arcjet observations. Local gas flow field results were found to affect the oxidation rate in a manner that cannot be predicted by previous mass loss correlations. The method holds promise for future modeling of materials gas-dynamic interactions for hypersonic flight.

  9. Grain Boundary Conformed Volumetric Mesh Generation from a Three-Dimensional Voxellated Polycrystalline Microstructure

    NASA Astrophysics Data System (ADS)

    Lee, Myeong-Jin; Jeon, Young-Ju; Son, Ga-Eun; Sung, Sihwa; Kim, Ju-Young; Han, Heung Nam; Cho, Soo Gyeong; Jung, Sang-Hyun; Lee, Sukbin

    2018-07-01

    We present a new comprehensive scheme for generating grain boundary conformed, volumetric mesh elements from a three-dimensional voxellated polycrystalline microstructure. From the voxellated image of a polycrystalline microstructure obtained from the Monte Carlo Potts model in the context of isotropic normal grain growth simulation, its grain boundary network is approximated as a curvature-maintained conformal triangular surface mesh using a set of in-house codes. In order to improve the surface mesh quality and to adjust mesh resolution, various re-meshing techniques in a commercial software are applied to the approximated grain boundary mesh. It is found that the aspect ratio, the minimum angle and the Jacobian value of the re-meshed surface triangular mesh are successfully improved. Using such an enhanced surface mesh, conformal volumetric tetrahedral elements of the polycrystalline microstructure are created using a commercial software, again. The resultant mesh seamlessly retains the short- and long-range curvature of grain boundaries and junctions as well as the realistic morphology of the grains inside the polycrystal. It is noted that the proposed scheme is the first to successfully generate three-dimensional mesh elements for polycrystals with high enough quality to be used for the microstructure-based finite element analysis, while the realistic characteristics of grain boundaries and grains are maintained from the corresponding voxellated microstructure image.

  10. Grain Boundary Conformed Volumetric Mesh Generation from a Three-Dimensional Voxellated Polycrystalline Microstructure

    NASA Astrophysics Data System (ADS)

    Lee, Myeong-Jin; Jeon, Young-Ju; Son, Ga-Eun; Sung, Sihwa; Kim, Ju-Young; Han, Heung Nam; Cho, Soo Gyeong; Jung, Sang-Hyun; Lee, Sukbin

    2018-03-01

    We present a new comprehensive scheme for generating grain boundary conformed, volumetric mesh elements from a three-dimensional voxellated polycrystalline microstructure. From the voxellated image of a polycrystalline microstructure obtained from the Monte Carlo Potts model in the context of isotropic normal grain growth simulation, its grain boundary network is approximated as a curvature-maintained conformal triangular surface mesh using a set of in-house codes. In order to improve the surface mesh quality and to adjust mesh resolution, various re-meshing techniques in a commercial software are applied to the approximated grain boundary mesh. It is found that the aspect ratio, the minimum angle and the Jacobian value of the re-meshed surface triangular mesh are successfully improved. Using such an enhanced surface mesh, conformal volumetric tetrahedral elements of the polycrystalline microstructure are created using a commercial software, again. The resultant mesh seamlessly retains the short- and long-range curvature of grain boundaries and junctions as well as the realistic morphology of the grains inside the polycrystal. It is noted that the proposed scheme is the first to successfully generate three-dimensional mesh elements for polycrystals with high enough quality to be used for the microstructure-based finite element analysis, while the realistic characteristics of grain boundaries and grains are maintained from the corresponding voxellated microstructure image.

  11. SU-F-T-517: Determining the Tissue Equivalence of a Brass Mesh Bolus in a Reconstructed Chest Wall Irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shekel, E; Epstein, D; Levin, D

    2016-06-15

    Purpose: To determine the tissue equivalence of a brass mesh bolus (RPD) in the setting of a reconstructed chest wall irradiation Methods: We measured breast skin dose delivered by a tangential field plan on an anthropomorphic phantom using Mosfet and nanoDot (Landauer) dosimeters in five different locations on the breast. We also measured skin dose using no bolus, 5mm and 10 mm superflab bolus. In the Eclipse treatment planning system (Varian, Palo Alto, CA) we calculated skin dose for different bolus thicknesses, ranging from 0 to 10 mm, in order to evaluate which calculation best matches the brass mesh measurements,more » as the brass mesh cannot be simulated due to artefacts.Finally, we measured depth dose behavior with the brass mesh bolus to verify that the bolus does not affect the dose to the breast itself beyond the build-up region. Results: Mosfet and nanoDot measurements were consistent with each other.As expected, skin dose measurements with no bolus had the least agreement with Eclipse calculation, while measurements for 5 and 10 mm agreed well with the calculation despite the difficulty in conforming superflab bolus to the breast contour. For the brass mesh the best agreement was for 3 mm bolus Eclipse calculation. For Mosfets, the average measurement was 90.8% of the expected dose, and for nanoDots 88.33% compared to 83.34%, 88.64% and 93.94% (2,3 and 5 mm bolus calculation respectively).The brass mesh bolus increased skin dose by approximately 25% but there was no dose increase beyond the build-up region. Conclusion: Brass mesh bolus is most equivalent to a 3 mm bolus, and does not affect the dose beyond the build-up region. The brass mesh cannot be directly calculated in Eclipse, hence a 3mm bolus calculation is a good reflection of the dose response to the brass mesh bolus.« less

  12. Management of Complex Abdominal Wall Defects Associated with Penetrating Abdominal Trauma

    DTIC Science & Technology

    2014-05-09

    recruitment): a new method of wound closure. Ann Plast Surg 2005;55:660–4. 8 Ramirez OM, Ruas E, Dellon AL. ‘Components separation’ method for closure of...patients with open abdomens closed by either permanent mesh, vicryl mesh or a modification of Ramirez ’ original method of components separation. These

  13. Primary fascial closure with mesh reinforcement is superior to bridged mesh repair for abdominal wall reconstruction.

    PubMed

    Booth, Justin H; Garvey, Patrick B; Baumann, Donald P; Selber, Jesse C; Nguyen, Alexander T; Clemens, Mark W; Liu, Jun; Butler, Charles E

    2013-12-01

    Many surgeons believe that primary fascial closure with mesh reinforcement should be the goal of abdominal wall reconstruction (AWR), yet others have reported acceptable outcomes when mesh is used to bridge the fascial edges. It has not been clearly shown how the outcomes for these techniques differ. We hypothesized that bridged repairs result in higher hernia recurrence rates than mesh-reinforced repairs that achieve fascial coaptation. We retrospectively reviewed prospectively collected data from consecutive patients with 1 year or more of follow-up, who underwent midline AWR between 2000 and 2011 at a single center. We compared surgical outcomes between patients with bridged and mesh-reinforced fascial repairs. The primary outcomes measure was hernia recurrence. Multivariate logistic regression analysis was used to identify factors predictive of or protective for complications. We included 222 patients (195 mesh-reinforced and 27 bridged repairs) with a mean follow-up of 31.1 ± 14.2 months. The bridged repairs were associated with a significantly higher risk of hernia recurrence (56% vs 8%; hazard ratio [HR] 9.5; p < 0.001) and a higher overall complication rate (74% vs 32%; odds ratio [OR] 3.9; p < 0.001). The interval to recurrence was more than 9 times shorter in the bridged group (HR 9.5; p < 0.001). Multivariate Cox proportional hazard regression analysis identified bridged repair and defect width > 15 cm to be independent predictors of hernia recurrence (HR 7.3; p < 0.001 and HR 2.5; p = 0.028, respectively). Mesh-reinforced AWRs with primary fascial coaptation resulted in fewer hernia recurrences and fewer overall complications than bridged repairs. Surgeons should make every effort to achieve primary fascial coaptation to reduce complications. Published by Elsevier Inc.

  14. A New Approach to an Old Technique-The S.U.T.R. First Technique.

    PubMed

    Jones, Frank; Lewis, Catherine; Knight, Darryl; Bacon, Louise; Patel, Vijay; Moore, Carolyn

    2018-04-01

    Ventral and incisional hernias of the abdominal wall are common problems treated by surgeons around the globe. Incisional hernias are common postoperative complications of abdominal laparotomies with a reported incidence of up to 20 per cent. The increasing use of prosthetic mesh in open ventral hernia repairs necessitated the development of different operative techniques used in the repairs. It also required that surgeons become facile with placement of the mesh in different anatomical positions on the abdominal wall. One of the most common locations is placement of the mesh in the underlay position. Many surgeons who use the underlay technique have expressed significant concerns. Among these are fear of an inadvertent bowel injury while placing the mesh, poor visualization during mesh placement, and the inability to use the underlay technique for difficult hernias. We present a very useful, if not, novel technique of open hernia repair using mesh in the underlay position that helps to 1) prevent complications, 2) facilitate easier mesh fixation, 3) simplify open repair of atypical ventral hernias, and 4) reduce total operative time while still adhering to the important fundamental principles of a tension-free hernia repair. This technique as we describe it has been compared with the old parachute technique, but we think this is a significant improvement of that seldom used technique. We believe the use of this technique for the underlay position makes open ventral hernia repair safer, faster, and easier; however, our goal for this article is to describe the procedure in detail. In addition, we recently have started using this technique to fix the mesh when doing the retrorectus approach as well.

  15. Challenges in the repair of large abdominal wall hernias in Nigeria: review of available options in resource limited environments.

    PubMed

    Ezeome, E R; Nwajiobi, C E

    2010-06-01

    To evaluate the challenges and outcome of management of large abdominal wall hernias in a resource limited environment and highlight the options available to surgeons in similar conditions. A review of prospectively collected data on large abdominal wall hernias managed between 2003 and 2009. University of Nigeria Teaching Hospital, Enugu, Nigeria and surrounding hospitals. Patients with hernias more than 4 cm in their largest diameter, patients with closely sited multiple hernias or failed previous repairs and in whom the surgeon considers direct repair inappropriate. Demographics of patients with large hernias, methods of hernia repair, recurrences, early and late complications following the repair. There were 41 patients, comprising 28 females and 13 males with ages 14 - 73 years. Most (53.7%) were incisional hernias. Gynecological surgeries (66.7%) were the most common initiating surgeries. Fifteen of the patients (36.6%) have had failed previous repairs, 41.5% were obese, five patients presented with intestinal obstruction. Thirty nine of the hernias were repaired with prolene mesh, one with composite mesh and one by danning technique. Most of the patients had extra peritoneal mesh placement. Three patients needed ventilator support. After a mean follow up of 18.6 months, there was a single failed repair. Two post op deaths were related to respiratory distress. There were 12 wound infection and 8 superficial wound dehiscence, all of which except one resolved with dressing. One reoperation was done following mesh infection and extrusion. Large abdominal wall hernia repair in resource limited environments present several challenges with wound infection and respiratory distress being the most notable. Surgeons who embark on it in these environments must be prepared t o secure the proper tissue replacement materials and have adequate ventilation support.

  16. Atelectasis after free rectus transfer and abdominal wall reconstruction.

    PubMed

    Lo, Jamie O; Weber, Stephen M; Andersen, Peter E; Gross, Neil D; Gosselin, Marc; Wax, Mark K

    2008-10-01

    Atelectasis is commonly encountered in patients undergoing rectus abdominus tissue transfer. Primary closure of the anterior rectus sheath may contribute to this process. Augmentation of the closure with mesh may decrease the incidence of Atelectasis. In this retrospective review 32 patients with preoperative and postoperative augmentation were compared to 23 who had primary closure of the anterior rectus sheath. Augmentation consisted of acellular dermis (25) or mesh (7). Postoperative atelectasis was radiographically detected in: 91% (n=29) of augmented patients versus 83% (n=19) of primary closure patients. Major atelectasis in 41% (n=13) of augmented patients versus 61% (n=14) of primary closure patients p<.05. The incidence of atelectasis was independent of skin flap size and operative times. The use of acellular dermis or mesh to augment the abdominal wall appears to reduce the high incidence of postoperative atelectasis following rectus-free flap harvest. Copyright (c) 2008 Wiley Periodicals, Inc. Head Neck 2008.

  17. Water Penetration through a Superhydrophobic Mesh During a Drop Impact.

    PubMed

    Ryu, Seunggeol; Sen, Prosenjit; Nam, Youngsuk; Lee, Choongyeop

    2017-01-06

    When a water drop impacts a mesh having submillimeter pores, a part of the drop penetrates through the mesh if the impact velocity is sufficiently large. Here we show that different surface wettability, i.e., hydrophobicity and superhydrophobicity, leads to different water penetration dynamics on a mesh during drop impact. We show, despite the water repellence of a superhydrophobic surface, that water can penetrate a superhydrophobic mesh more easily (i.e., at a lower impact velocity) over a hydrophobic mesh via a penetration mechanism unique to a superhydrophobic mesh. On a superhydrophobic mesh, the water penetration can occur during the drop recoil stage, which appears at a lower impact velocity than the critical impact velocity for water penetration right upon impact. We propose that this unique water penetration on a superhydrophobic mesh can be attributed to the combination of the hydrodynamic focusing and the momentum transfer from the water drop when it is about to bounce off the surface, at which point the water drop retrieves most of its kinetic energy due to the negligible friction on superhydrophobic surfaces.

  18. Water Penetration through a Superhydrophobic Mesh During a Drop Impact

    NASA Astrophysics Data System (ADS)

    Ryu, Seunggeol; Sen, Prosenjit; Nam, Youngsuk; Lee, Choongyeop

    2017-01-01

    When a water drop impacts a mesh having submillimeter pores, a part of the drop penetrates through the mesh if the impact velocity is sufficiently large. Here we show that different surface wettability, i.e., hydrophobicity and superhydrophobicity, leads to different water penetration dynamics on a mesh during drop impact. We show, despite the water repellence of a superhydrophobic surface, that water can penetrate a superhydrophobic mesh more easily (i.e., at a lower impact velocity) over a hydrophobic mesh via a penetration mechanism unique to a superhydrophobic mesh. On a superhydrophobic mesh, the water penetration can occur during the drop recoil stage, which appears at a lower impact velocity than the critical impact velocity for water penetration right upon impact. We propose that this unique water penetration on a superhydrophobic mesh can be attributed to the combination of the hydrodynamic focusing and the momentum transfer from the water drop when it is about to bounce off the surface, at which point the water drop retrieves most of its kinetic energy due to the negligible friction on superhydrophobic surfaces.

  19. Use of negative pressure wound therapy in the management of infected abdominal wounds containing mesh: an analysis of outcomes.

    PubMed

    Baharestani, Mona Mylene; Gabriel, Allen

    2011-04-01

    The purpose of this study was to examine the clinical outcomes of negative pressure wound therapy (NPWT) using reticulated open-cell foam (ROCF) in the adjunctive management of abdominal wounds with exposed and known infected synthetic mesh. A non randomised, retrospective review of medical records for 21 consecutive patients with infected abdominal wounds treated with NPWT was conducted. All abdominal wounds contained exposed synthetic mesh [composite, polypropylene (PP), or knitted polyglactin 910 (PG) mesh]. Demographic and bacteriological data, wound history, pre-NPWT and comparative post-NPWT, operative procedures and complications, hospital length of stay (LOS) and wound healing outcomes were all analysed. Primary endpoints measured were (1) hospital LOS prior to initiation of NPWT, (2) total time on NPWT, (3) hospital LOS from NPWT initiation to discharge and (4) wound closure status at discharge. A total of 21 patients with abdominal wounds with exposed, infected mesh were treated with NPWT. Aetiology of the wounds was ventral hernia repair (n = 11) and acute abdominal wall defect (n = 10). Prior to NPWT initiation, the mean hospital LOS for the composite, PP and PG meshes were 76 days (range: 21-171 days), 51 days (range: 32-62 days) and 19 days (range: 12-39 days), respectively. The mean hospital LOS following initiation of NPWT for wounds with exposed composite, PP and PG mesh were 28, 31 and 32 days, respectively. Eighteen of the 21 wounds (86%) reached full closure after a mean time of 26 days of NPWT and a mean hospital LOS of 30 days postinitiation of NPWT. Three wounds, all with composite mesh left in situ, did not reach full closure, although all exhibited decreased wound dimensions, granulating beds and decreased surface area exposure of mesh. During NPWT/ROCF, one hypoalbuminemic patient with exposed PP mesh developed an enterocutaneous fistula over a prior enterotomy site. This patient subsequently underwent total mesh extraction, takedown of the fistula and PP mesh replacement followed by reinstitution of NPWT and flap closure. In addition to appropriate systemic antibiotics and nutritional optimisation, the adjunctive use of NPWT resulted in successful closure of 86% of infected abdominal wounds with exposed prosthetic mesh. Patient hospital LOS (except those with PG mesh), operative procedures and readmissions were decreased during NPWT compared with treatment prior to NPWT. Future multi-site prospective, controlled studies would provide a strong evidence base from which treatment decisions could be made in the management of these challenging and costly cases. © 2010 The Authors. © 2010 Blackwell Publishing Ltd and Medicalhelplines.com Inc.

  20. Box truss analysis and technology development. Task 1: Mesh analysis and control

    NASA Technical Reports Server (NTRS)

    Bachtell, E. E.; Bettadapur, S. S.; Coyner, J. V.

    1985-01-01

    An analytical tool was developed to model, analyze and predict RF performance of box truss antennas with reflective mesh surfaces. The analysis system is unique in that it integrates custom written programs for cord tied mesh surfaces, thereby drastically reducing the cost of analysis. The analysis system is capable of determining the RF performance of antennas under any type of manufacturing or operating environment by integrating together the various disciplines of design, finite element analysis, surface best fit analysis and RF analysis. The Integrated Mesh Analysis System consists of six separate programs: The Mesh Tie System Model Generator, The Loadcase Generator, The Model Optimizer, The Model Solver, The Surface Topography Solver and The RF Performance Solver. Additionally, a study using the mesh analysis system was performed to determine the effect of on orbit calibration, i.e., surface adjustment, on a typical box truss antenna.

  1. Evaluation of mechanical properties in metal wire mesh supported selective catalytic reduction (SCR) catalyst structures

    NASA Astrophysics Data System (ADS)

    Rajath, S.; Siddaraju, C.; Nandakishora, Y.; Roy, Sukumar

    2018-04-01

    The objective of this research is to evaluate certain specific mechanical properties of certain stainless steel wire mesh supported Selective catalytic reduction catalysts structures wherein the physical properties of the metal wire mesh and also its surface treatments played vital role thereby influencing the mechanical properties. As the adhesion between the stainless steel wire mesh and the catalyst material determines the bond strength and the erosion resistance of catalyst structures, surface modifications of the metal- wire mesh structure in order to facilitate the interface bonding is therefore very important to realize enhanced level of mechanical properties. One way to enhance such adhesion properties, the stainless steel wire mesh is treated with the various acids, i.e., chromic acid, phosphoric acid including certain mineral acids and combination of all those in various molar ratios that could generate surface active groups on metal surface that promotes good interface structure between the metal- wire mesh and metal oxide-based catalyst material and then the stainless steel wire mesh is dipped in the glass powder slurry containing some amount of organic binder. As a result of which the said catalyst material adheres to the metal-wire mesh surface more effectively that improves the erosion profile of supported catalysts structure including bond strength.

  2. Simultaneous Prosthetic Mesh Abdominal Wall Reconstruction with Abdominoplasty for Ventral Hernia and Severe Rectus Diastasis Repairs

    PubMed Central

    Cheesborough, Jennifer E.

    2015-01-01

    Background: Standard abdominoplasty rectus plication techniques may not suffice for severe cases of rectus diastasis. In the authors’ experience, prosthetic mesh facilitates the repair of severe rectus diastasis with or without concomitant ventral hernias. Methods: A retrospective review of all abdominal wall surgery patients treated in the past 8 years by the senior author (G.A.D.) was performed. Patients with abdominoplasty and either rectus diastasis repair with mesh or a combined ventral hernia repair were analyzed. Results: Thirty-two patients, 29 women and three men, underwent mesh-reinforced midline repair with horizontal or vertical abdominoplasty. Patient characteristics included the following: mean age, 53 years; mean body mass index, 26 kg/m2; average width of diastasis or hernia, 6.7 cm; and average surgery time, 151 minutes. There were no surgical-site infections and two surgical-site occurrences—two seromas treated with drainage in the office. After an average of 471 days’ follow-up, none of the patients had recurrence of a bulge or a hernia. Conclusions: For patients with significant rectus diastasis, with or without concomitant hernias, the described mesh repair is both safe and durable. Although this operation requires additional dissection and placement of prosthetic mesh in the retrorectus plane, it may be safely combined with standard horizontal or vertical abdominoplasty skin excision techniques to provide an aesthetically pleasing overall result. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV. PMID:25539311

  3. [The Open Retromuscular Preperitoneal Mesh Repair of the Incisional Lateral Hernia - Technique and Results of a Prospective Cohort Study].

    PubMed

    Isemer, Friedrich-Eckart; Dietz, Ulrich; Ackermann, Maximilian

    2018-05-18

    Surgical approaches to flank hernias have been poorly standardised. The most demanding issues in intermuscular net insertion are the limited area in the dorsal direction and the difficulties in fixing the net to the costal arch or the iliac crest. This is why many different surgical procedures have been published. From August 2015 to October 2016, nine patients with a primary incisional lateral hernia received open retromuscular preperitoneal mesh repair. In intermuscular mesh placement, the mesh size must be smaller at smaller values of the CPA (costopelvic angle). On the dorsal side of the reference stretch RS of 10 cm between costal arch and iliac crest, fixations are necessary to achieve stability. Retroperitoneal preperitoneal net implantation is unrestricted by the patient's anatomy. The placement of the mesh is similar to the Stoppa procedure and almost any size can be used with little fixation. Remodeling of the abdominal wall can be comfortably achieved. All 9 patients underwent retromuscular preperitoneal mesh repair. The hernia size was 92.85 cm 2 with a corresponding mesh size of 426.22 cm 2 . No adverse side effects or surgical complications were observed; the length of hospital stay was between 3 to 7 days; the follow up was 3 to 18 months, with a mean follow-up of 9.1 months. In a follow-up questionnaire, the patients reported a high satisfaction rate with a grade of 1,2 (school mark); there was no recurrence. The pain level decreased from VAS grade 4 preoperatively to 1.2 postoperatively. 7 patients had no pain at all. In conclusion, adequate overlap of the implanted mesh can be achieved in the preperitoneal retromuscular space even in large hernias. Fixation of the mesh to the costal arch or the iliac crest is not necessary and would only induce postoperative pain. Long-term stability depends on the size of the mesh. Remodeling of the abdominal wall with closure of the fascia above the mesh can be easily achieved. Georg Thieme Verlag KG Stuttgart · New York.

  4. A new class of actuator surface models for wind turbines

    NASA Astrophysics Data System (ADS)

    Yang, Xiaolei; Sotiropoulos, Fotis

    2018-05-01

    Actuator line model has been widely employed in wind turbine simulations. However, the standard actuator line model does not include a model for the turbine nacelle which can significantly impact turbine wake characteristics as shown in the literature. Another disadvantage of the standard actuator line model is that more geometrical features of turbine blades cannot be resolved on a finer mesh. To alleviate these disadvantages of the standard model, we develop a new class of actuator surface models for turbine blades and nacelle to take into account more geometrical details of turbine blades and include the effect of turbine nacelle. In the actuator surface model for blade, the aerodynamic forces calculated using the blade element method are distributed from the surface formed by the foil chords at different radial locations. In the actuator surface model for nacelle, the forces are distributed from the actual nacelle surface with the normal force component computed in the same way as in the direct forcing immersed boundary method and the tangential force component computed using a friction coefficient and a reference velocity of the incoming flow. The actuator surface model for nacelle is evaluated by simulating the flow over periodically placed nacelles. Both the actuator surface simulation and the wall-resolved large-eddy simulation are carried out. The comparison shows that the actuator surface model is able to give acceptable results especially at far wake locations on a very coarse mesh. It is noted that although this model is employed for the turbine nacelle in this work, it is also applicable to other bluff bodies. The capability of the actuator surface model in predicting turbine wakes is assessed by simulating the flow over the MEXICO (Model experiments in Controlled Conditions) turbine and a hydrokinetic turbine.

  5. Radical lateral body-wall resection for fibrosarcoma with reconstruction using polypropylene mesh and a caudal superficial epigastric axial pattern flap: a prospective clinical study of the technique and results in 6 cats.

    PubMed

    Lidbetter, David A; Williams, Fred A; Krahwinkel, D J; Adams, William H

    2002-01-01

    To describe and evaluate a technique for radical resection of the lateral body wall for treatment of fibrosarcoma with reconstruction using polypropylene mesh and a caudal superficial epigastric axial pattern flap in cats. Prospective, clinical study. Six client-owned cats with fibrosarcoma. Six cats with histologically confirmed fibrosarcoma of the lateral body wall were staged using radiography and/or computer tomography scanning. Preoperative radiotherapy was used in 3 cats. All cats had the lateral abdominal wall resected and reconstructed with polypropylene mesh. A caudal superficial epigastric flap was mobilized and rotated to close the skin deficit. The animals were evaluated after surgery for wound complications, tumor recurrence, and metastasis. Outcome was assessed by patient examination and client consultation. Minor dehiscence of the skin flaps occurred in 2 cats, and 1 other cat was successfully resuscitated from respiratory and cardiac arrest after surgery. All tissue specimens were tumor-free at the surgical margins. Follow-up times ranged from 12 to 21 months, with a mean time of 17.2 months. None of the cats had evidence of local tumor recurrence or metastasis; outcome was judged good to excellent in all cats. Radical lateral body-wall resection and reconstruction is an effective technique for achieving local tumor control with acceptable patient morbidity. Further studies are needed to assess whether the technique will result in improved tumor-free intervals and survival times. Copyright 2002 by The American College of Veterinary Surgeons

  6. Surface orientation effects on bending properties of surgical mesh are independent of tensile properties.

    PubMed

    Simon, David D; Andrews, Sharon M; Robinson-Zeigler, Rebecca; Valdes, Thelma; Woods, Terry O

    2018-02-01

    Current mechanical testing of surgical mesh focuses primarily on tensile properties even though implanted devices are not subjected to pure tensile loads. Our objective was to determine the flexural (bending) properties of surgical mesh and determine if they correlate with mesh tensile properties. The flexural rigidity values of 11 different surgical mesh designs were determined along three textile directions (machine, cross-machine, and 45° to machine; n = 5 for each) using ASTM D1388-14 while tracking surface orientation. Tensile testing was also performed on the same specimens using ASTM D882-12. Linear regressions were performed to compare mesh flexural rigidity to mesh thickness, areal mass density, filament diameter, ultimate tensile strength, and maximum extension. Of 33 mesh specimen groups, 30 had significant differences in flexural rigidity values when comparing surface orientations (top and bottom). Flexural rigidity and mesh tensile properties also varied with textile direction (machine and cross-machine). There was no strong correlation between the flexural and tensile properties, with mesh thickness having the best overall correlation with flexural rigidity. Currently, surface orientation is not indicated on marketed surgical mesh, and a single mesh may behave differently depending on the direction of loading. The lack of correlation between flexural stiffness and tensile properties indicates the need to examine mesh bending stiffness to provide a more comprehensive understanding of surgical mesh mechanical behaviors. Further investigation is needed to determine if these flexural properties result in the surgical mesh behaving mechanically different depending on implantation direction. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 854-862, 2018. © 2017 Wiley Periodicals, Inc.

  7. On the Use of CAD-Native Predicates and Geometry in Surface Meshing

    NASA Technical Reports Server (NTRS)

    Aftosmis, M. J.

    1999-01-01

    Several paradigms for accessing computer-aided design (CAD) geometry during surface meshing for computational fluid dynamics are discussed. File translation, inconsistent geometry engines, and nonnative point construction are all identified as sources of nonrobustness. The paper argues in favor of accessing CAD parts and assemblies in their native format, without translation, and for the use of CAD-native predicates and constructors in surface mesh generation. The discussion also emphasizes the importance of examining the computational requirements for exact evaluation of triangulation predicates during surface meshing.

  8. Diffraction Analysis of Antennas With Mesh Surfaces

    NASA Technical Reports Server (NTRS)

    Rahmat-Samii, Yahya

    1987-01-01

    Strip-aperture model replaces wire-grid model. Far-field radiation pattern of antenna with mesh reflector calculated more accurately with new strip-aperture model than with wire-grid model of reflector surface. More adaptable than wire-grid model to variety of practical configurations and decidedly superior for reflectors in which mesh-cell width exceeds mesh thickness. Satisfies reciprocity theorem. Applied where mesh cells are no larger than tenth of wavelength. Small cell size permits use of simplifying approximation that reflector-surface current induced by electromagnetic field is present even in apertures. Approximation useful in calculating far field.

  9. The continuing challenge of parastomal hernia: failure of a novel polypropylene mesh repair.

    PubMed Central

    Morris-Stiff, G.; Hughes, L. E.

    1998-01-01

    In an attempt to reduce the high recurrence rate after repair of parastomal hernia, a technique was devised in which non-absorbable mesh was used to provide a permanent closure of the gap between the emerging bowel and abdominal wall. Seven patients were treated during the period 1990-1992. Five-year follow-up has given disappointing results, with recurrent hernia in 29% of cases and serious complications, including obstruction and dense adhesions to the intra-abdominal mesh, in 57% and a mesh-related abscess in 15% of cases. This study highlights a dual problem--failure of a carefully sutured mesh to maintain an occlusive position, and complications of the mesh itself. The poor results obtained with this technique together with the disappointing results with other methods described in the literature confirms that parastomal hernia presents a continuing challenge. Images Figure 1 Figure 2 PMID:9682640

  10. Computational approach to estimating the effects of blood properties on changes in intra-stent flow.

    PubMed

    Benard, Nicolas; Perrault, Robert; Coisne, Damien

    2006-08-01

    In this study various blood rheological assumptions are numerically investigated for the hemodynamic properties of intra-stent flow. Non-newtonian blood properties have never been implemented in blood coronary stented flow investigation, although its effects appear essential for a correct estimation and distribution of wall shear stress (WSS) exerted by the fluid on the internal vessel surface. Our numerical model is based on a full 3D stent mesh. Rigid wall and stationary inflow conditions are applied. Newtonian behavior, non-newtonian model based on Carreau-Yasuda relation and a characteristic newtonian value defined with flow representative parameters are introduced in this research. Non-newtonian flow generates an alteration of near wall viscosity norms compared to newtonian. Maximal WSS values are located in the center part of stent pattern structure and minimal values are focused on the proximal stent wire surface. A flow rate increase emphasizes fluid perturbations, and generates a WSS rise except for interstrut area. Nevertheless, a local quantitative analysis discloses an underestimation of WSS for modelisation using a newtonian blood flow, with clinical consequence of overestimate restenosis risk area. Characteristic viscosity introduction appears to present a useful option compared to rheological modelisation based on experimental data, with computer time gain and relevant results for quantitative and qualitative WSS determination.

  11. High-Fidelity Geometric Modeling and Mesh Generation for Mechanics Characterization of Polycrystalline Materials

    DTIC Science & Technology

    2014-10-26

    From the parameterization results, we extract adaptive and anisotropic T-meshes for the further T- spline surface construction. Finally, a gradient flow...field-based method [7, 12] to generate adaptive and anisotropic quadrilateral meshes, which can be used as the control mesh for high-order T- spline ...parameterization results, we extract adaptive and anisotropic T-meshes for the further T- spline surface construction. Finally, a gradient flow-based

  12. High-Fidelity Geometric Modeling and Mesh Generation for Mechanics Characterization of Polycrystalline Materials

    DTIC Science & Technology

    2015-01-07

    and anisotropic quadrilateral meshes, which can be used as the control mesh for high-order T- spline surface modeling. Archival publications (published...anisotropic T-meshes for the further T- spline surface construction. Finally, a gradient flow-based method is developed to improve the T-mesh quality...shade-off. Halos are bright or dark thin regions around the boundary of the sample. These false edges around the object make many segmentation

  13. Critically safe volume vacuum pickup for use in wet or dry cleanup of radioactive enclosures

    DOEpatents

    Zeren, J.D.

    1993-12-28

    A physical compact vacuum pickup device of critically safe volume and geometric shape is provided for use in radioactive enclosures, such as a small glove box, to facilitate manual cleanup of either wet or dry radioactive material. The device is constructed and arranged so as to remain safe when filled to capacity with plutonium-239 oxide. Two fine mesh filter bags are supported on the exterior of a rigid fine mesh stainless steel cup. This assembly is sealed within, and spaced from, the interior walls of a stainless steel canister. An air inlet communicates with the interior of the canister. A modified conventional vacuum head is physically connected to, and associated with, the interior of the mesh cup. The volume of the canister, as defined by the space between the mesh cup and the interior walls of the canister, forms a critically safe volume and geometric shape for dry radioactive particles that are gathered within the canister. A critically safe liquid volume is maintained by operation of a suction terminating float valve, and/or by operation of redundant vacuum check/liquid drain valves and placement of the air inlet. 5 figures.

  14. Critically safe volume vacuum pickup for use in wet or dry cleanup of radioactive enclosures

    DOEpatents

    Zeren, Joseph D.

    1993-12-28

    A physical compact vacuum pickup device of critically safe volume and geometric shape is provided for use in radioactive enclosures, such as a small glove box, to facilitate manual cleanup of either wet or dry radioactive material. The device is constructed and arranged so as to remain safe when filled to capacity with plutonium-239 oxide. Two fine mesh filter bags are supported on the exterior of a rigid fine mesh stainless steel cup. This assembly is sealed within, and spaced from, the interior walls of a stainless steel canister. An air inlet communicates with the interior of the canister. A modified conventional vacuum head is physically connected to, and associated with, the interior of the mesh cup. The volume of the canister, as defined by the space between the mesh cup and the interior walls of the canister, forms a critically safe volume and geometric shape for dry radioactive particles that are gathered within the canister. A critically safe liquid volume is maintained by operation of a suction terminating float valve, and/or by operation of redundant vacuum check/liquid drain valves and placement of the air inlet.

  15. Tetrahedral and polyhedral mesh evaluation for cerebral hemodynamic simulation--a comparison.

    PubMed

    Spiegel, Martin; Redel, Thomas; Zhang, Y; Struffert, Tobias; Hornegger, Joachim; Grossman, Robert G; Doerfler, Arnd; Karmonik, Christof

    2009-01-01

    Computational fluid dynamic (CFD) based on patient-specific medical imaging data has found widespread use for visualizing and quantifying hemodynamics in cerebrovascular disease such as cerebral aneurysms or stenotic vessels. This paper focuses on optimizing mesh parameters for CFD simulation of cerebral aneurysms. Valid blood flow simulations strongly depend on the mesh quality. Meshes with a coarse spatial resolution may lead to an inaccurate flow pattern. Meshes with a large number of elements will result in unnecessarily high computation time which is undesirable should CFD be used for planning in the interventional setting. Most CFD simulations reported for these vascular pathologies have used tetrahedral meshes. We illustrate the use of polyhedral volume elements in comparison to tetrahedral meshing on two different geometries, a sidewall aneurysm of the internal carotid artery and a basilar bifurcation aneurysm. The spatial mesh resolution ranges between 5,119 and 228,118 volume elements. The evaluation of the different meshes was based on the wall shear stress previously identified as a one possible parameter for assessing aneurysm growth. Polyhedral meshes showed better accuracy, lower memory demand, shorter computational speed and faster convergence behavior (on average 369 iterations less).

  16. Pitfalls in retromuscular mesh repair for incisional hernia: the importance of the "fatty triangle".

    PubMed

    Conze, J; Prescher, A; Klinge, U; Saklak, M; Schumpelick, V

    2004-08-01

    Open retromuscular mesh repair has become a standard procedure in incisional hernia repair. This technique led to a significant decrease of recurrences. Recurrences after this technique typically occur at the upper mesh border and are a result of the technical complexity of reaching the postulated underlay of 5 cm in the region of the linea alba. We performed an anatomical study in human corpses to investigate the abdominal wall with its different structures, with emphasis on the overlap of the mesh under the linea alba. The overlap can be achieved by incision of the posterior lamina of the rectus sheath, on both sides close to the linea alba. The incision opens the preperitoneal space and appears in the shape of a "fatty triangle". The anterior lamina of the rectus sheath above the hernia defect remains intact and facilitates a sufficient thrust bearing for a retromuscular mesh implantation. Knowledge of the anatomy and preparation of the "fatty triangle" enables a mesh positioning according to the principles of retromuscular mesh repair.

  17. Discrete Surface Evolution and Mesh Deformation for Aircraft Icing Applications

    NASA Technical Reports Server (NTRS)

    Thompson, David; Tong, Xiaoling; Arnoldus, Qiuhan; Collins, Eric; McLaurin, David; Luke, Edward; Bidwell, Colin S.

    2013-01-01

    Robust, automated mesh generation for problems with deforming geometries, such as ice accreting on aerodynamic surfaces, remains a challenging problem. Here we describe a technique to deform a discrete surface as it evolves due to the accretion of ice. The surface evolution algorithm is based on a smoothed, face-offsetting approach. We also describe a fast algebraic technique to propagate the computed surface deformations into the surrounding volume mesh while maintaining geometric mesh quality. Preliminary results presented here demonstrate the ecacy of the approach for a sphere with a prescribed accretion rate, a rime ice accretion, and a more complex glaze ice accretion.

  18. Distribution of chloride, pH, resistivity, and sulfate levels in backfill for mechanically-stabilized earth walls and implications for corrosion testing : [summary].

    DOT National Transportation Integrated Search

    2015-04-01

    Road construction projects often require mechanically stabilized earth (MSE), earthwork : construction in which soil is retained by walls and reinforced with wire mesh, metal strips, : and structural geosynthetics (geotextile or geogrid). The fill so...

  19. A voxel-based finite element model for the prediction of bladder deformation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chai Xiangfei; Herk, Marcel van; Hulshof, Maarten C. C. M.

    2012-01-15

    Purpose: A finite element (FE) bladder model was previously developed to predict bladder deformation caused by bladder filling change. However, two factors prevent a wide application of FE models: (1) the labor required to construct a FE model with high quality mesh and (2) long computation time needed to construct the FE model and solve the FE equations. In this work, we address these issues by constructing a low-resolution voxel-based FE bladder model directly from the binary segmentation images and compare the accuracy and computational efficiency of the voxel-based model used to simulate bladder deformation with those of a classicalmore » FE model with a tetrahedral mesh. Methods: For ten healthy volunteers, a series of MRI scans of the pelvic region was recorded at regular intervals of 10 min over 1 h. For this series of scans, the bladder volume gradually increased while rectal volume remained constant. All pelvic structures were defined from a reference image for each volunteer, including bladder wall, small bowel, prostate (male), uterus (female), rectum, pelvic bone, spine, and the rest of the body. Four separate FE models were constructed from these structures: one with a tetrahedral mesh (used in previous study), one with a uniform hexahedral mesh, one with a nonuniform hexahedral mesh, and one with a low-resolution nonuniform hexahedral mesh. Appropriate material properties were assigned to all structures and uniform pressure was applied to the inner bladder wall to simulate bladder deformation from urine inflow. Performance of the hexahedral meshes was evaluated against the performance of the standard tetrahedral mesh by comparing the accuracy of bladder shape prediction and computational efficiency. Results: FE model with a hexahedral mesh can be quickly and automatically constructed. No substantial differences were observed between the simulation results of the tetrahedral mesh and hexahedral meshes (<1% difference in mean dice similarity coefficient to manual contours and <0.02 cm difference in mean standard deviation of residual errors). The average equation solving time (without manual intervention) for the first two types of hexahedral meshes increased to 2.3 h and 2.6 h compared to the 1.1 h needed for the tetrahedral mesh, however, the low-resolution nonuniform hexahedral mesh dramatically decreased the equation solving time to 3 min without reducing accuracy. Conclusions: Voxel-based mesh generation allows fast, automatic, and robust creation of finite element bladder models directly from binary segmentation images without user intervention. Even the low-resolution voxel-based hexahedral mesh yields comparable accuracy in bladder shape prediction and more than 20 times faster in computational speed compared to the tetrahedral mesh. This approach makes it more feasible and accessible to apply FE method to model bladder deformation in adaptive radiotherapy.« less

  20. Triangle Geometry Processing for Surface Modeling and Cartesian Grid Generation

    NASA Technical Reports Server (NTRS)

    Aftosmis, Michael J. (Inventor); Melton, John E. (Inventor); Berger, Marsha J. (Inventor)

    2002-01-01

    Cartesian mesh generation is accomplished for component based geometries, by intersecting components subject to mesh generation to extract wetted surfaces with a geometry engine using adaptive precision arithmetic in a system which automatically breaks ties with respect to geometric degeneracies. During volume mesh generation, intersected surface triangulations are received to enable mesh generation with cell division of an initially coarse grid. The hexagonal cells are resolved, preserving the ability to directionally divide cells which are locally well aligned.

  1. Triangle geometry processing for surface modeling and cartesian grid generation

    DOEpatents

    Aftosmis, Michael J [San Mateo, CA; Melton, John E [Hollister, CA; Berger, Marsha J [New York, NY

    2002-09-03

    Cartesian mesh generation is accomplished for component based geometries, by intersecting components subject to mesh generation to extract wetted surfaces with a geometry engine using adaptive precision arithmetic in a system which automatically breaks ties with respect to geometric degeneracies. During volume mesh generation, intersected surface triangulations are received to enable mesh generation with cell division of an initially coarse grid. The hexagonal cells are resolved, preserving the ability to directionally divide cells which are locally well aligned.

  2. Effect of surface condition to temperature distribution in living tissue during cryopreservation

    NASA Astrophysics Data System (ADS)

    Nozawa, M.; Hatakeyama, S.; Sugimoto, Y.; Sasaki, H.

    2017-12-01

    The temperature distribution of the simulated living tissue is measured for the improvement of the cooling rate during cryopreservation when the surface condition of the test sample is changed by covering the stainless steel mesh. Agar is used as a simulated living tissue and is filled inside the test sample. The variation of the transient temperature with mesh by the directly immersion in the liquid nitrogen is measured. The temperatures on the sample surface and the inside of the sample are measured by use of type T thermocouples. It is confirmed that on the sample surface there is the slightly temperature increase than that in the saturated liquid nitrogen at the atmospheric pressure. It is found by the comparison of the degree of superheat with or without the mesh that the surface temperature of the test sample with the mesh is lower than that without the mesh. On the other hand, the time series variations of the temperature located in the center of the sample does not change with or without the mesh. It is considered that the center of the sample used is too deep from the surface to respond to the boiling state on the sample surface.

  3. Automatic generation of endocardial surface meshes with 1-to-1 correspondence from cine-MR images

    NASA Astrophysics Data System (ADS)

    Su, Yi; Teo, S.-K.; Lim, C. W.; Zhong, L.; Tan, R. S.

    2015-03-01

    In this work, we develop an automatic method to generate a set of 4D 1-to-1 corresponding surface meshes of the left ventricle (LV) endocardial surface which are motion registered over the whole cardiac cycle. These 4D meshes have 1- to-1 point correspondence over the entire set, and is suitable for advanced computational processing, such as shape analysis, motion analysis and finite element modelling. The inputs to the method are the set of 3D LV endocardial surface meshes of the different frames/phases of the cardiac cycle. Each of these meshes is reconstructed independently from border-delineated MR images and they have no correspondence in terms of number of vertices/points and mesh connectivity. To generate point correspondence, the first frame of the LV mesh model is used as a template to be matched to the shape of the meshes in the subsequent phases. There are two stages in the mesh correspondence process: (1) a coarse matching phase, and (2) a fine matching phase. In the coarse matching phase, an initial rough matching between the template and the target is achieved using a radial basis function (RBF) morphing process. The feature points on the template and target meshes are automatically identified using a 16-segment nomenclature of the LV. In the fine matching phase, a progressive mesh projection process is used to conform the rough estimate to fit the exact shape of the target. In addition, an optimization-based smoothing process is used to achieve superior mesh quality and continuous point motion.

  4. Ultrastructural studies on the boundary tissue of the seminiferous tubules of different mammals.

    PubMed

    Cieciura, L; Jaszczuk-Jarosz, B; Pietrzkowska, K

    1988-01-01

    The aims of our studies were to compare the ultrastructure of the boundary tissue of seminiferous tubules of various mammals (rat, mouse, hamster, guinea pig, rabbit, ram, bull and man). Visual analysis of electron micrographs revealed the similarity of structure of all layers at investigated animals. The boundary tissue consists of 4 layers: 1) amorphous inner lamina, 2) cellular inner lamina, 3) amorphous outer lamina, 4) cellular outer lamina. The outer lamina of boundary tissue of rat, mouse and hamster revealed in histochemical reactions meshes resembling honey-combs. The wall of seminiferous canalicules of bull and ram consists of more bigger and different structure than one at the other laboratory animals. The most different structure of boundary tissue in man was observed. The capillary vessels penetrate in the myofibroblastic layer, when comparted to that found in other mammals on the surface of the wall.

  5. Methanethiol Concentrations and Sea-Air Fluxes in the Subarctic NE Pacific Ocean

    NASA Astrophysics Data System (ADS)

    Kiene, R. P.; Williams, T. E.; Esson, K.; Tortell, P. D.; Dacey, J. W. H.

    2017-12-01

    Exchange of volatile organic sulfur from the ocean to the atmosphere impacts the global sulfur cycle and the climate system and is thought to occur mainly via the gas dimethylsulfide (DMS). DMS is produced during degradation of the abundant phytoplankton osmolyte dimethylsulfoniopropionate (DMSP) but bacteria can also convert dissolved DMSP into the sulfur gas methanethiol (MeSH). MeSH has been difficult to measure in seawater because of its high chemical and biological reactivity and, thus, information on MeSH concentrations, distribution and sea-air fluxes is limited. We measured MeSH in the northeast subarctic Pacific Ocean in July 2016, along transects with strong phytoplankton abundance gradients. Water samples obtained with Niskin bottles were analyzed for MeSH by purge-and-trap gas chromatography. Depth profiles showed that MeSH concentrations were high near the surface and declined with depth. Surface waters (5 m depth) had an average MeSH concentration of 0.75 nM with concentrations reaching up to 3nM. MeSH concentrations were correlated (r = 0.47) with microbial turnover of dissolved DMSP which ranged up to 236 nM per day. MeSH was also correlated with total DMSP (r = 0.93) and dissolved DMS (r = 0.63), supporting the conclusion that DMSP was a major precursor of MeSH. Surface water MeSH:DMS concentration ratios averaged 0.19 and ranged up to 0.50 indicating that MeSH was a significant fraction of the volatile sulfur pool in surface waters. Sea-air fluxes of MeSH averaged 15% of the combined DMS+MeSH flux, therefore MeSH contributed an important fraction of the sulfur emitted to the atmosphere from the subarctic NE Pacific Ocean.

  6. A Simplified Mesh Deformation Method Using Commercial Structural Analysis Software

    NASA Technical Reports Server (NTRS)

    Hsu, Su-Yuen; Chang, Chau-Lyan; Samareh, Jamshid

    2004-01-01

    Mesh deformation in response to redefined or moving aerodynamic surface geometries is a frequently encountered task in many applications. Most existing methods are either mathematically too complex or computationally too expensive for usage in practical design and optimization. We propose a simplified mesh deformation method based on linear elastic finite element analyses that can be easily implemented by using commercially available structural analysis software. Using a prescribed displacement at the mesh boundaries, a simple structural analysis is constructed based on a spatially varying Young s modulus to move the entire mesh in accordance with the surface geometry redefinitions. A variety of surface movements, such as translation, rotation, or incremental surface reshaping that often takes place in an optimization procedure, may be handled by the present method. We describe the numerical formulation and implementation using the NASTRAN software in this paper. The use of commercial software bypasses tedious reimplementation and takes advantage of the computational efficiency offered by the vendor. A two-dimensional airfoil mesh and a three-dimensional aircraft mesh were used as test cases to demonstrate the effectiveness of the proposed method. Euler and Navier-Stokes calculations were performed for the deformed two-dimensional meshes.

  7. Comparative study of safety and efficacy of synthetic surgical glue for mesh fixation in ventral rectopexy.

    PubMed

    Silveira, Raquel Kelner; Domingie, Sophie; Kirzin, Sylvain; de Melo Filho, Djalma Agripino; Portier, Guillaume

    2017-10-01

    Ventral mesh rectopexy (VMR) is a surgical option to treat rectal prolapse with pelvic floor dysfunction (PFD). Using synthetic surgical glue to fix the mesh to the anterior rectal wall after ventral dissection could be advantageous in comparison with sutured or stapled fixation. This study aimed to evaluate the safety and efficacy of synthetic surgical glue for mesh fixation compared with suture mesh fixation in VMR. This observational cohort study is a retrospective analysis conducted in a University Hospital Pelvic Surgery Center. All consecutive female patients (n = 176) who underwent laparoscopic or laparotomic VMR between January 2009 and December 2014 were included. Two groups were defined based on mesh fixation technique of the rectal wall: VMR with synthetic glue (n = 66) and VMR with suture (n = 110). The recurrence-free survival after VMR was determined by Kaplan-Meier method and multivariate analysis by Cox regression. Short-term postoperative complications, postoperative symptom improvement, the need for complementary treatment postoperatively, and procedure length were evaluated. A total of 176 females patients (mean age, 58.6 ± 13.7 years) underwent VMR with synthetic mesh. Mean recurrence-free survivals after VMR were 17.16 (CI 95% 16.54-17.80) and 17.33 (CI 95% 16.89-17.77) months in the glue group and the suture group, respectively (p > 0.05). Cox regression identified an independent effect on the recurrence risk of the external rectal prolapse, alone, or in combination with other anatomical abnormalities (HR = 0.37; CI 95% 0.14-0.93; p = 0.03). There was no significant difference of short-term postoperative morbidity, procedure length, postoperative symptom improvement, or need for complementary treatment postoperatively between suture versus glue groups (all p > 0.05). Use of glue to fix the mesh in VMR was safe and had no impact on outcomes. External prolapse was the unique significant predictive factor for recurrence.

  8. Efficient computation of turbulent flow in ribbed passages using a non-overlapping near-wall domain decomposition method

    NASA Astrophysics Data System (ADS)

    Jones, Adam; Utyuzhnikov, Sergey

    2017-08-01

    Turbulent flow in a ribbed channel is studied using an efficient near-wall domain decomposition (NDD) method. The NDD approach is formulated by splitting the computational domain into an inner and outer region, with an interface boundary between the two. The computational mesh covers the outer region, and the flow in this region is solved using the open-source CFD code Code_Saturne with special boundary conditions on the interface boundary, called interface boundary conditions (IBCs). The IBCs are of Robin type and incorporate the effect of the inner region on the flow in the outer region. IBCs are formulated in terms of the distance from the interface boundary to the wall in the inner region. It is demonstrated that up to 90% of the region between the ribs in the ribbed passage can be removed from the computational mesh with an error on the friction factor within 2.5%. In addition, computations with NDD are faster than computations based on low Reynolds number (LRN) models by a factor of five. Different rib heights can be studied with the same mesh in the outer region without affecting the accuracy of the friction factor. This is tested with six different rib heights in an example of a design optimisation study. It is found that the friction factors computed with NDD are almost identical to the fully-resolved results. When used for inverse problems, NDD is considerably more efficient than LRN computations because only one computation needs to be performed and only one mesh needs to be generated.

  9. Negative pressure wound therapy with instillation, a cost-effective treatment for abdominal mesh exposure.

    PubMed

    Deleyto, E; García-Ruano, A; González-López, J R

    2018-04-01

    Negative pressure wound therapy with instillation (NPWTi) has been proved to be a safe and effective treatment option for abdominal wall wound dehiscence with mesh exposure. Our aim in this study is to examine whether it is also cost-effective. We performed a retrospective cohort study with 45 patients treated for postoperative abdominal wall wound dehiscence and exposed mesh: 34 were treated with conventional wound therapy (CWT) and 11 with NPWTi. We carried out a cost analysis for each treatment group using the Diagnosis-related group (DRG) system and a second evaluation using the calculated costs "per hospital stay". The differences between NPWTi and CWT were calculated with both evaluation systems. Comparative analysis was performed using the Mann-Whitney U test. Mean costs using the DRG estimation were 29,613.71€ for the CWT group and 15,093.37€ for the NPWTi group, and according to the calculated expenses "per hospital stay", 17,322.88€ for the CWT group and 15,284.22€ for the NPWTi group. NPWTi showed a reduction in the total expense of treatment, related to a reduction in episodes of hospitalization and number of surgeries required to achieve wound closure. However, differences were not statistically significant in our sample. NPWTi proves to be an efficient treatment option for abdominal wall wound dehiscence with mesh exposure, compared to CWT. More trials aimed to optimize treatment protocols will lead to an additional increase in NPWTi efficiency. In addition, to generalize our results, further studies with larger samples would be necessary.

  10. Delayed vaginal and urethral mesh exposure: 10 years after TVT surgery.

    PubMed

    Khanuengkitkong, Siwatchaya; Lo, Tsia-Shu; Dass, Anil Krishna

    2013-03-01

    Delayed mesh exposure after tension-free vaginal tape (TVT) procedure is rare. We report a case of mesh exposure into the vagina and urethra that developed 10 years after TVT surgery. A 58-year-old postmenopausal woman presented with mixed urinary incontinence. She was investigated, and her stress urinary incontinence was cured with a TVT procedure 10 years ago. She was then scheduled follow-up annually. Two years postsurgery, a granulation tissue was observed and excised at the vaginal incision site. Vaginal examination 10 years postsurgery showed vaginal mesh erosion 0.5 cm from urethral meatus. Cystoscopy revealed concomitant urethral erosion at the posterior urethral wall. Mesh excision was performed, and urethra and vagina were repaired in layers. Postoperative recovery was uneventful. This finding shows that, although rare, complications can occur even after 10 years of TVT surgery.

  11. Sternal resection for metastasis from thyroid carcinoma and reconstruction with the sandwiched Marlex and stainless steel mesh.

    PubMed

    Haraguchi, Shuji; Yamashita, Yasuo; Yamashita, Koji; Hioki, Masafumi; Matsumoto, Koshi; Shimizu, Kazuo

    2004-04-01

    A case of 69-year-old woman with a solitary sternal bone metastasis from thyroid carcinoma undergoing surgical therapy was reported here. On admission, most part of the body of the sternum was destroyed by tumor. Subtotal sternectomy was performed and a part of the major pectoral muscles adherent to the sternal tumor was also resected. The chest wall defect was reconstructed with a sandwiched Marlex and stainless steel mesh. Pathological examination of the resected specimen revealed metastatic papillary carcinoma of the thyroid. Her postoperative course was uneventful. The reconstruction with Marlex and stainless steel mesh seemed to be an appropriate procedure to prevent paradoxical movement of the thorax and protect the intrathoracic organs. Stainless steel mesh compensated for limited resiliency of Marlex mesh and remained rigid in all directions.

  12. Bioprosthetic tissue matrices in complex abdominal wall reconstruction.

    PubMed

    Broyles, Justin M; Abt, Nicholas B; Sacks, Justin M; Butler, Charles E

    2013-12-01

    Complex abdominal defects are difficult problems encountered by surgeons in multiple specialties. Although current evidence supports the primary repair of these defects with mesh reinforcement, it is unclear which mesh is superior for any given clinical scenario. The purpose of this review was to explore the characteristics of and clinical relevance behind bioprosthetic tissue matrices in an effort to better clarify their role in abdominal wall reconstruction. We reviewed the peer-reviewed literature on the use of bioprosthetic mesh in human subjects. Basic science articles and large retrospective and prospective reviews were included in author's analysis. The clinical performance and characteristics of 13 bioprosthetic tissue matrices were evaluated. The majority of the products evaluated perform well in contaminated fields, where the risk of wound-healing difficulties is high. Clinical outcomes, which included infection, reherniation, and bulge formation, were variable, and the majority of the studies had a mean follow-up of less than 24 months. Although bioprosthetic matrix has a multitude of indications within the growing field of abdominal wall reconstruction, the functionality, regenerative capacity, and long-term fate of these products have yet to be fully established. Furthermore, the clinical performance, indications, and contraindications for each type of matrix need to be fully evaluated in long-term outcome studies.

  13. Bioprosthetic Tissue Matrices in Complex Abdominal Wall Reconstruction

    PubMed Central

    Broyles, Justin M.; Abt, Nicholas B.; Sacks, Justin M.

    2013-01-01

    Background: Complex abdominal defects are difficult problems encountered by surgeons in multiple specialties. Although current evidence supports the primary repair of these defects with mesh reinforcement, it is unclear which mesh is superior for any given clinical scenario. The purpose of this review was to explore the characteristics of and clinical relevance behind bioprosthetic tissue matrices in an effort to better clarify their role in abdominal wall reconstruction. Methods: We reviewed the peer-reviewed literature on the use of bioprosthetic mesh in human subjects. Basic science articles and large retrospective and prospective reviews were included in author’s analysis. The clinical performance and characteristics of 13 bioprosthetic tissue matrices were evaluated. Results: The majority of the products evaluated perform well in contaminated fields, where the risk of wound-healing difficulties is high. Clinical outcomes, which included infection, reherniation, and bulge formation, were variable, and the majority of the studies had a mean follow-up of less than 24 months. Conclusions: Although bioprosthetic matrix has a multitude of indications within the growing field of abdominal wall reconstruction, the functionality, regenerative capacity, and long-term fate of these products have yet to be fully established. Furthermore, the clinical performance, indications, and contraindications for each type of matrix need to be fully evaluated in long-term outcome studies. PMID:25289285

  14. Surgical Resection and Scarification for Chronic Seroma Post-Ventral Hernia Mesh Repair

    PubMed Central

    Vasilakis, Vasileios; Cook, Kristin; Wilson, Dorian

    2014-01-01

    Patient: Male, 52 Final Diagnosis: Seroma Symptoms: Abdominal discomfort • abdominal mass Medication: — Clinical Procedure: Excision and evacuation of the complex seroma Specialty: Surgery Objective: Unusual or unexpected effect of treatment Background: The aim of this report is to present a new surgical approach in the definitive management of challenging cases of abdominal wall seroma following herniorrhaphy with mesh. Case Report: We describe the case of a 56-year-old male with a 4-year history of a complex abdominal wall seroma. He had undergone fluid aspiration twice without success. On physical examination, the mass was supraumbilical and measured 15×10 cm. Computer tomography (CT) scan revealed a complex encapsulated formation overall measuring 10.1×17.3×17.3 cm in AP, transverse, and craniocaudal dimensions, respectively. In this case complete resection was not safe due to the anatomic relationship of the posterior aspect of the pseudocapsule and the mesh. Intraoperatively, the anterior and lateral aspects of the pseudocapsule were resected and an argon beam was used to scarify the residual posterior pseudocapsule and prevent recurrence. This technique was successful in preventing reaccumulation of the seroma. Conclusions: Capsulectomy and scarification of the remnant pseudocapsule is an acceptable and safe surgical option for complex chronic abdominal wall seromas. PMID:25430512

  15. Texturing of continuous LOD meshes with the hierarchical texture atlas

    NASA Astrophysics Data System (ADS)

    Birkholz, Hermann

    2006-02-01

    For the rendering of detailed virtual environments, trade-offs have to be made between image quality and rendering time. An immersive experience of virtual reality always demands high frame-rates with the best reachable image qual-ity. Continuous Level of Detail (cLoD) triangle-meshes provide an continuous spectrum of detail for a triangle mesh that can be used to create view-dependent approximations of the environment in real-time. This enables the rendering with a constant number of triangles and thus with constant frame-rates. Normally the construction of such cLoD mesh representations leads to the loss of all texture information of the original mesh. To overcome this problem, a parameter domain can be created, in order to map the surface properties (colour, texture, normal) to it. This parameter domain can be used to map the surface properties back to arbitrary approximations of the original mesh. The parameter domain is often a simplified version of the mesh to be parameterised. This limits the reachable simplification to the domain mesh which has to map the surface of the original mesh with the least possible stretch. In this paper, a hierarchical domain mesh is presented, that scales between very coarse domain meshes and good property-mapping.

  16. Airplane Mesh Development with Grid Density Studies

    NASA Technical Reports Server (NTRS)

    Cliff, Susan E.; Baker, Timothy J.; Thomas, Scott D.; Lawrence, Scott L.; Rimlinger, Mark J.

    1999-01-01

    Automatic Grid Generation Wish List Geometry handling, including CAD clean up and mesh generation, remains a major bottleneck in the application of CFD methods. There is a pressing need for greater automation in several aspects of the geometry preparation in order to reduce set up time and eliminate user intervention as much as possible. Starting from the CAD representation of a configuration, there may be holes or overlapping surfaces which require an intensive effort to establish cleanly abutting surface patches, and collections of many patches may need to be combined for more efficient use of the geometrical representation. Obtaining an accurate and suitable body conforming grid with an adequate distribution of points throughout the flow-field, for the flow conditions of interest, is often the most time consuming task for complex CFD applications. There is a need for a clean unambiguous definition of the CAD geometry. Ideally this would be carried out automatically by smart CAD clean up software. One could also define a standard piece-wise smooth surface representation suitable for use by computational methods and then create software to translate between the various CAD descriptions and the standard representation. Surface meshing remains a time consuming, user intensive procedure. There is a need for automated surface meshing, requiring only minimal user intervention to define the overall density of mesh points. The surface mesher should produce well shaped elements (triangles or quadrilaterals) whose size is determined initially according to the surface curvature with a minimum size for flat pieces, and later refined by the user in other regions if necessary. Present techniques for volume meshing all require some degree of user intervention. There is a need for fully automated and reliable volume mesh generation. In addition, it should be possible to create both surface and volume meshes that meet guaranteed measures of mesh quality (e.g. minimum and maximum angle, stretching ratios, etc.).

  17. Fabrication of cylindrical micro-parts using synchronous rotary scan-projection lithography and chemical etching

    NASA Astrophysics Data System (ADS)

    Ito, Kaiki; Suzuki, Yuta; Horiuchi, Toshiyuki

    2017-07-01

    Lithographical patterning on the surface of a fine pipe with a thin wall is required for fabricating three-dimensional micro-parts. For this reason, a new exposure system for printing patterns on a cylindrical pipe by synchronous rotary scan-projection exposure was developed. Using the exposure system, stent-like resist patterns with a width of 251 μm were printed on a surface of stainless-steel pipe with an outer diameter of 2 mm. The exposure time was 30 s. Next, the patterned pipe was chemically etched. As a result, a stent-like mesh pipe with a line width of 230 μm was fabricated. It was demonstrated that the new method had a potential to be applied to fabrications of stent and other cylindrical micro-parts.

  18. Generating Inviscid and Viscous Fluid-Flow Simulations over an Aircraft Surface Using a Fluid-Flow Mesh

    NASA Technical Reports Server (NTRS)

    Rodriguez, David L. (Inventor); Sturdza, Peter (Inventor)

    2013-01-01

    Fluid-flow simulation over a computer-generated aircraft surface is generated using inviscid and viscous simulations. A fluid-flow mesh of fluid cells is obtained. At least one inviscid fluid property for the fluid cells is determined using an inviscid fluid simulation that does not simulate fluid viscous effects. A set of intersecting fluid cells that intersects the aircraft surface are identified. One surface mesh polygon of the surface mesh is identified for each intersecting fluid cell. A boundary-layer prediction point for each identified surface mesh polygon is determined. At least one boundary-layer fluid property for each boundary-layer prediction point is determined using the at least one inviscid fluid property of the corresponding intersecting fluid cell and a boundary-layer simulation that simulates fluid viscous effects. At least one updated fluid property for at least one fluid cell is determined using the at least one boundary-layer fluid property and the inviscid fluid simulation.

  19. Optimal design of permeable fiber network structures for fog harvesting.

    PubMed

    Park, Kyoo-Chul; Chhatre, Shreerang S; Srinivasan, Siddarth; Cohen, Robert E; McKinley, Gareth H

    2013-10-29

    Fog represents a large untapped source of potable water, especially in arid climates. Numerous plants and animals use textural and chemical features on their surfaces to harvest this precious resource. In this work, we investigate the influence of the surface wettability characteristics, length scale, and weave density on the fog-harvesting capability of woven meshes. We develop a combined hydrodynamic and surface wettability model to predict the overall fog-collection efficiency of the meshes and cast the findings in the form of a design chart. Two limiting surface wettability constraints govern the re-entrainment of collected droplets and clogging of mesh openings. Appropriate tuning of the wetting characteristics of the surfaces, reducing the wire radii, and optimizing the wire spacing all lead to more efficient fog collection. We use a family of coated meshes with a directed stream of fog droplets to simulate a natural foggy environment and demonstrate a five-fold enhancement in the fog-collecting efficiency of a conventional polyolefin mesh. The design rules developed in this work can be applied to select a mesh surface with optimal topography and wetting characteristics to harvest enhanced water fluxes over a wide range of natural convected fog environments.

  20. 13. VIEW OF AREAWAY 104 LOOKING SOUTHEAST, TOWARD ANIMAL QUARTERS. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. VIEW OF AREAWAY 104 LOOKING SOUTHEAST, TOWARD ANIMAL QUARTERS. WOOD STUD WALL WITH WIRE MESH INFILL HAS BEEN ADDED. HORIZONTAL WOOD PANELING ON WALLS IS PAINTED. FLOOR IS CONCRETE SLAB. - Presidio of San Francisco, Cavalry Stables, Cowles Street, between Lincoln Boulevard & McDowell Street, San Francisco, San Francisco County, CA

  1. Giant spigelian hernia due to abdominal wall injury: a case report.

    PubMed

    Topal, Ersun; Kaya, Ekrem; Topal, Naile Bolca; Sahin, Ilker

    2007-02-01

    Spigelian hernia is a rare clinical entity. It is difficult to diagnose due to its location. In this article we report the case of a giant spigelian hernia consequent to abdominal wall injury. The neck of the hernia was 10 cm in diameter. We repaired this hernia with a polypropylene mesh.

  2. Turbine component cooling channel mesh with intersection chambers

    DOEpatents

    Lee, Ching-Pang; Marra, John J

    2014-05-06

    A mesh (35) of cooling channels (35A, 35B) with an array of cooling channel intersections (42) in a wall (21, 22) of a turbine component. A mixing chamber (42A-C) at each intersection is wider (W1, W2)) than a width (W) of each of the cooling channels connected to the mixing chamber. The mixing chamber promotes swirl, and slows the coolant for more efficient and uniform cooling. A series of cooling meshes (M1, M2) may be separated by mixing manifolds (44), which may have film cooling holes (46) and/or coolant refresher holes (48).

  3. Porcine dermis implants in soft-tissue reconstruction: current status

    PubMed Central

    Smart, Neil J; Bryan, Nicholas; Hunt, John A; Daniels, Ian R

    2014-01-01

    Soft-tissue reconstruction for a variety of surgical conditions, such as abdominal wall hernia or pelvic organ prolapse, remains a challenge. There are numerous meshes available that may be simply categorized as either synthetic or biologic. Within biologic meshes, porcine dermal meshes have come to dominate the market. This review examines the current evidence for their use and the limitations of knowledge. Although there is increasing evidence to support their safety, long-term follow-up studies that support their efficacy are lacking. Numerous clinical trials that remain ongoing may help elucidate their precise role in soft-tissue reconstruction. PMID:24648721

  4. Histologic and biomechanical evaluation of a novel macroporous polytetrafluoroethylene knit mesh compared to lightweight and heavyweight polypropylene mesh in a porcine model of ventral incisional hernia repair

    PubMed Central

    Melman, L.; Jenkins, E. D.; Hamilton, N. A.; Bender, L. C.; Brodt, M. D.; Deeken, C. R.; Greco, S. C.; Frisella, M. M.

    2013-01-01

    Purpose To evaluate the biocompatibility of heavyweight polypropylene (HWPP), lightweight polypropylene (LWPP), and monofilament knit polytetrafluoroethylene (mkPTFE) mesh by comparing biomechanics and histologic response at 1, 3, and 5 months in a porcine model of incisional hernia repair. Methods Bilateral full-thickness abdominal wall defects measuring 4 cm in length were created in 27 Yucatan minipigs. Twenty-one days after hernia creation, animals underwent bilateral preperitoneal ventral hernia repair with 8 × 10 cm pieces of mesh. Repairs were randomized to Bard®Mesh (HWPP, Bard/Davol, http://www.davol.com), ULTRAPRO® (LWPP, Ethicon, http://www.ethicon.com), and GORE®INFINIT Mesh (mkPTFE, Gore & Associates, http://www.gore.com). Nine animals were sacrificed at each timepoint (1, 3, and 5 months). At harvest, a 3 × 4 cm sample of mesh and incorporated tissue was taken from the center of the implant site and subjected to uniaxial tensile testing at a rate of 0.42 mm/s. The maximum force (N) and tensile strength (N/cm) were measured with a tensiometer, and stiffness (N/mm) was calculated from the slope of the force-versus-displacement curve. Adjacent sections of tissue were stained with hematoxylin and eosin (H&E) and analyzed for inflammation, fibrosis, and tissue ingrowth. Data are reported as mean ± SEM. Statistical significance (P < 0.05) was determined using a two-way ANOVA and Bonferroni post-test. Results No significant difference in maximum force was detected between meshes at any of the time points (P > 0.05 for all comparisons). However, for each mesh type, the maximum strength at 5 months was significantly lower than that at 1 month (P < 0.05). No significant difference in stiffness was detected between the mesh types or between timepoints (P > 0.05 for all comparisons). No significant differences with regard to inflammation, fibrosis, or tissue ingrowth were detected between mesh types at any time point (P > 0.09 for all comparisons). However, over time, inflammation decreased significantly for all mesh types (P < 0.001) and tissue ingrowth reached a slight peak between 1 and 3 months (P = 0.001) but did not significantly change thereafter (P > 0.09). Conclusions The maximum tensile strength of mesh in the abdominal wall decreased over time for HWPP, LWPP, and mkPTFE mesh materials alike. This trend may actually reflect inability to adequately grip specimens at later time points rather than any mesh-specific trend. Histologically, inflammation decreased with time (P = 0.000), and tissue ingrowth increased (P = 0.019) for all meshes. No specific trends were observed between the polypropylene meshes and the monofilament knit PTFE, suggesting that this novel construction may be a suitable alternative to existing polypropylene meshes. PMID:21279663

  5. Histologic and biomechanical evaluation of a novel macroporous polytetrafluoroethylene knit mesh compared to lightweight and heavyweight polypropylene mesh in a porcine model of ventral incisional hernia repair.

    PubMed

    Melman, L; Jenkins, E D; Hamilton, N A; Bender, L C; Brodt, M D; Deeken, C R; Greco, S C; Frisella, M M; Matthews, B D

    2011-08-01

    To evaluate the biocompatibility of heavyweight polypropylene (HWPP), lightweight polypropylene (LWPP), and monofilament knit polytetrafluoroethylene (mkPTFE) mesh by comparing biomechanics and histologic response at 1, 3, and 5 months in a porcine model of incisional hernia repair. Bilateral full-thickness abdominal wall defects measuring 4 cm in length were created in 27 Yucatan minipigs. Twenty-one days after hernia creation, animals underwent bilateral preperitoneal ventral hernia repair with 8 × 10 cm pieces of mesh. Repairs were randomized to Bard(®)Mesh (HWPP, Bard/Davol, http://www.davol.com), ULTRAPRO(®) (LWPP, Ethicon, http://www.ethicon.com), and GORE(®)INFINIT Mesh (mkPTFE, Gore & Associates, http://www.gore.com). Nine animals were sacrificed at each timepoint (1, 3, and 5 months). At harvest, a 3 × 4 cm sample of mesh and incorporated tissue was taken from the center of the implant site and subjected to uniaxial tensile testing at a rate of 0.42 mm/s. The maximum force (N) and tensile strength (N/cm) were measured with a tensiometer, and stiffness (N/mm) was calculated from the slope of the force-versus-displacement curve. Adjacent sections of tissue were stained with hematoxylin and eosin (H&E) and analyzed for inflammation, fibrosis, and tissue ingrowth. Data are reported as mean ± SEM. Statistical significance (P < 0.05) was determined using a two-way ANOVA and Bonferroni post-test. No significant difference in maximum force was detected between meshes at any of the time points (P > 0.05 for all comparisons). However, for each mesh type, the maximum strength at 5 months was significantly lower than that at 1 month (P < 0.05). No significant difference in stiffness was detected between the mesh types or between timepoints (P > 0.05 for all comparisons). No significant differences with regard to inflammation, fibrosis, or tissue ingrowth were detected between mesh types at any time point (P > 0.09 for all comparisons). However, over time, inflammation decreased significantly for all mesh types (P < 0.001) and tissue ingrowth reached a slight peak between 1 and 3 months (P = 0.001) but did not significantly change thereafter (P > 0.09). The maximum tensile strength of mesh in the abdominal wall decreased over time for HWPP, LWPP, and mkPTFE mesh materials alike. This trend may actually reflect inability to adequately grip specimens at later time points rather than any mesh-specific trend. Histologically, inflammation decreased with time (P = 0.000), and tissue ingrowth increased (P = 0.019) for all meshes. No specific trends were observed between the polypropylene meshes and the monofilament knit PTFE, suggesting that this novel construction may be a suitable alternative to existing polypropylene meshes.

  6. Method of and apparatus for modeling interactions

    DOEpatents

    Budge, Kent G.

    2004-01-13

    A method and apparatus for modeling interactions can accurately model tribological and other properties and accommodate topological disruptions. Two portions of a problem space are represented, a first with a Lagrangian mesh and a second with an ALE mesh. The ALE and Lagrangian meshes are constructed so that each node on the surface of the Lagrangian mesh is in a known correspondence with adjacent nodes in the ALE mesh. The interaction can be predicted for a time interval. Material flow within the ALE mesh can accurately model complex interactions such as bifurcation. After prediction, nodes in the ALE mesh in correspondence with nodes on the surface of the Lagrangian mesh can be mapped so that they are once again adjacent to their corresponding Lagrangian mesh nodes. The ALE mesh can then be smoothed to reduce mesh distortion that might reduce the accuracy or efficiency of subsequent prediction steps. The process, from prediction through mapping and smoothing, can be repeated until a terminal condition is reached.

  7. Three new models for evaluation of standard involute spur gear mesh stiffness

    NASA Astrophysics Data System (ADS)

    Liang, Xihui; Zhang, Hongsheng; Zuo, Ming J.; Qin, Yong

    2018-02-01

    Time-varying mesh stiffness is one of the main internal excitation sources of gear dynamics. Accurate evaluation of gear mesh stiffness is crucial for gear dynamic analysis. This study is devoted to developing new models for spur gear mesh stiffness evaluation. Three models are proposed. The proposed model 1 can give very accurate mesh stiffness result but the gear bore surface must be assumed to be rigid. Enlighted by the proposed model 1, our research discovers that the angular deflection pattern of the gear bore surface of a pair of meshing gears under a constant torque basically follows a cosine curve. Based on this finding, two other models are proposed. The proposed model 2 evaluates gear mesh stiffness by using angular deflections at different circumferential angles of an end surface circle of the gear bore. The proposed model 3 requires using only the angular deflection at an arbitrary circumferential angle of an end surface circle of the gear bore but this model can only be used for a gear with the same tooth profile among all teeth. The proposed models are accurate in gear mesh stiffness evaluation and easy to use. Finite element analysis is used to validate the accuracy of the proposed models.

  8. PBF Reactor Building (PER620). Camera faces south along west wall. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PBF Reactor Building (PER-620). Camera faces south along west wall. Gap between native lava rock and concrete basement walls is being backfilled and compacted. Wire mesh protects workers from falling rock. Note penetrations for piping that will carry secondary coolant water to Cooling Tower. Photographer: Holmes. Date: June 15, 1967. INEEL negative no. 67-3665 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID

  9. Superhydrophobic hierarchical structure carbon mesh films for oil/water separation application

    NASA Astrophysics Data System (ADS)

    Lu, Zhaoxia; Huang, Xing; Wang, Lisheng

    2017-08-01

    In this study, we showed that a superoleophobic mesh with the self-cleaning ability could be readily prepared by a facile spray-coating method on stainless steel mesh. Poly(methyl methacrylate) was employed to provide a stable strength between carbon nanotubes and steel mesh surface. The effect of opening size of these steel meshes on surface wetting has been investigated. The dynamics of liquid droplets was investigated as well. The as-prepared meshes exhibited both superhydrophobicity and superoleophilicity and could effectively separate water from the oil and water mixture. The present study contributes to the development of oil and water separation materials for marine industrial application.

  10. Laminar and turbulent flow computations of Type 4 shock-shock interference aerothermal loads using unstructured grids

    NASA Technical Reports Server (NTRS)

    Vemaganti, Gururaja R.

    1994-01-01

    This report presents computations for the Type 4 shock-shock interference flow under laminar and turbulent conditions using unstructured grids. Mesh adaptation was accomplished by remeshing, refinement, and mesh movement. Two two-equation turbulence models were used to analyze turbulent flows. The mean flow governing equations and the turbulence governing equations are solved in a coupled manner. The solution algorithm and the details pertaining to its implementation on unstructured grids are described. Computations were performed at two different freestream Reynolds numbers at a freestream Mach number of 11. Effects of the variation in the impinging shock location are studied. The comparison of the results in terms of wall heat flux and wall pressure distributions is presented.

  11. Repair of Postoperative Abdominal Hernia in a Child with Congenital Omphalocele Using Porcine Dermal Matrix

    PubMed Central

    Mylona, E.; Tsakalidis, C.; Spyridakis, I.; Mitsiakos, G.; Karagianni, P.

    2016-01-01

    Introduction. Incisional hernias are a common complication appearing after abdominal wall defects reconstruction, with omphalocele and gastroschisis being the most common etiologies in children. Abdominal closure of these defects represents a real challenge for pediatric surgeons with many surgical techniques and various prosthetic materials being used for this purpose. Case Report. We present a case of repair of a postoperative ventral hernia occurring after congenital omphalocele reconstruction in a three-and-a-half-year-old child using an acellular, sterile, porcine dermal mesh. Conclusion. Non-cross-linked acellular porcine dermal matrix is an appropriate mesh used for the reconstruction of abdominal wall defects and their postoperative complications like large ventral hernias with success and preventing their recurrence. PMID:27110247

  12. Repair of Postoperative Abdominal Hernia in a Child with Congenital Omphalocele Using Porcine Dermal Matrix.

    PubMed

    Lambropoulos, V; Mylona, E; Mouravas, V; Tsakalidis, C; Spyridakis, I; Mitsiakos, G; Karagianni, P

    2016-01-01

    Introduction. Incisional hernias are a common complication appearing after abdominal wall defects reconstruction, with omphalocele and gastroschisis being the most common etiologies in children. Abdominal closure of these defects represents a real challenge for pediatric surgeons with many surgical techniques and various prosthetic materials being used for this purpose. Case Report. We present a case of repair of a postoperative ventral hernia occurring after congenital omphalocele reconstruction in a three-and-a-half-year-old child using an acellular, sterile, porcine dermal mesh. Conclusion. Non-cross-linked acellular porcine dermal matrix is an appropriate mesh used for the reconstruction of abdominal wall defects and their postoperative complications like large ventral hernias with success and preventing their recurrence.

  13. Umbilical endometriosis associated with large umbilical hernia. Case report.

    PubMed

    Stojanovic, M; Radojkovic, M; Jeremic, L; Zlatic, A; Stanojevic, G; Janjic, D; Mihajlovic, S; Dimov, I; Kostov, M; Zdravkovic, M; Stojanovic, M

    2014-01-01

    Umbilical endometriosis is a rare condition, usually following laparoscopic and surgical procedures involving the umbilicus.Spontaneous umbilical endometriosis occurring without any previous abdominal or uterine surgery is extremely rare. The maximal depth of penetration of the umbilical endometriosis described is up to fascial level. There have been only two cases of endometriosis reported arising within umbilical hernia. The authors report a case of a patient with spontaneous umbilical endometriosis associated with a large umbilical hernia, treated by surgical excision and mesh repair of the abdominal wall. To the best of our knowledge, this is the first described case of the association of umbilical endometriosis with a large umbilical hernia that requires prosthetic mesh repair of the abdominal wall defect. Celsius.

  14. Embedded Ag/Ni Metal-Mesh with Low Surface Roughness As Transparent Conductive Electrode for Optoelectronic Applications.

    PubMed

    Chen, Xiaolian; Guo, Wenrui; Xie, Liming; Wei, Changting; Zhuang, Jinyong; Su, Wenming; Cui, Zheng

    2017-10-25

    Metal-mesh is one of the contenders to replace indium tin oxide (ITO) as transparent conductive electrodes (TCEs) for optoelectronic applications. However, considerable surface roughness accompanying metal-mesh type of transparent electrodes has been the root cause of electrical short-circuiting for optoelectronic devices, such as organic light-emitting diode (OLED) and organic photovoltaic (OPV). In this work, a novel approach to making metal-mesh TCE has been proposed that is based on hybrid printing of silver (Ag) nanoparticle ink and electroplating of nickel (Ni). By polishing back the electroplated Ni, an extremely smooth surface was achieved. The fabricated Ag/Ni metal-mesh TCE has a surface roughness of 0.17 nm, a low sheet resistance of 2.1 Ω/□, and a high transmittance of 88.6%. The figure of merit is 1450, which is 30 times better than ITO. In addition, the Ag/Ni metal-mesh TCE shows outstanding mechanical flexibility and environmental stability at high temperature and humidity. Using the polished Ag/Ni metal-mesh TCE, a flexible quantum dot light-emitting diode (QLED) was fabricated with an efficiency of 10.4 cd/A and 3.2 lm/W at 1000 cd/m 2 .

  15. Robust laser-structured asymmetrical PTFE mesh for underwater directional transportation and continuous collection of gas bubbles

    NASA Astrophysics Data System (ADS)

    Yin, Kai; Yang, Shuai; Dong, Xinran; Chu, Dongkai; Duan, Ji-An; He, Jun

    2018-06-01

    We report a simple, efficient method to fabricate micro/nanoscale hierarchical structures on one side of polytetrafluoroethylene mesh surfaces, using one-step femtosecond laser direct writing technology. The laser-treated surface exhibits superhydrophobicity in air and superaerophilicity in water, resulting in the mesh possessing the hydrophobic/superhydrophobic asymmetrical property. Bubbles can pass through the mesh from the untreated side to the laser-treated side but cannot pass through the mesh in the opposite direction. The asymmetrical mesh can therefore be designed for the directional transportation and continuous collection of gas bubbles in aqueous environments. Furthermore, the asymmetrical mesh shows excellent stability during corrosion and abrasion tests. These findings may provide an efficient route for fabricating a durable asymmetrical mesh for the directional and continuous transport of gas bubbles.

  16. Membrane Shell Reflector Segment Antenna

    NASA Technical Reports Server (NTRS)

    Fang, Houfei; Im, Eastwood; Lin, John; Moore, James

    2012-01-01

    The mesh reflector is the only type of large, in-space deployable antenna that has successfully flown in space. However, state-of-the-art large deployable mesh antenna systems are RF-frequency-limited by both global shape accuracy and local surface quality. The limitations of mesh reflectors stem from two factors. First, at higher frequencies, the porosity and surface roughness of the mesh results in loss and scattering of the signal. Second, the mesh material does not have any bending stiffness and thus cannot be formed into true parabolic (or other desired) shapes. To advance the deployable reflector technology at high RF frequencies from the current state-of-the-art, significant improvements need to be made in three major aspects: a high-stability and highprecision deployable truss; a continuously curved RF reflecting surface (the function of the surface as well as its first derivative are both continuous); and the RF reflecting surface should be made of a continuous material. To meet these three requirements, the Membrane Shell Reflector Segment (MSRS) antenna was developed.

  17. Synthetic vascular graft fabrication by a precipitation-flotation method.

    PubMed

    Kowligi, R R; von Maltzahn, W W; Eberhart, R C

    1988-01-01

    The authors report a new technique for fabricating synthetic vascular grafts. It involves spraying a polymer solution (generated by mixing polymer solution and nitrogen gas in a spray nozzle) onto the surface of a flowing nonsolvent liquid (water): polymer fibers form during precipitation of the spray drops as they travel on the water surface, until picked up by a partially submerged rotating mandrel. Depending on process conditions, these fibers may aggregate to form a continuous layer or remain separated until they are picked up. A number of independent process variables allow control of characteristics of the conduits: gas and polymer solution feed rates, nozzle traverse speed, nonsolvent (water) flow rate, spray-mandrel spacing, and mandrel rpm. The SEM reveals that the graft wall consists of numerous fused polymeric fibers arrayed in both the circumferential and axial directions. The inner surface resembles a mesh of closely spaced fused fibers. The conduits have walls with interconnected pores (water permeabilities between 0.05 to 7.0 ml/min-cm2); nonporous surfaces also can be made. Tensile stress of the grafts at failure (in radial direction) varied between 0.05 to 2.3 MPa, whereas elongation at break ranged between 150 to 600%, depending on the porosity and fabrication conditions. A major advantage of this technique is its ability to produce grafts of a wide variety of fiber sizes and fusion characteristics in an inexpensive, safe, and reliable fashion.

  18. Mesh fixation in laparoscopic incisional hernia repair: glue fixation provides attachment strength similar to absorbable tacks but differs substantially in different meshes.

    PubMed

    Rieder, Erwin; Stoiber, Martin; Scheikl, Verena; Poglitsch, Marcus; Dal Borgo, Andrea; Prager, Gerhard; Schima, Heinrich

    2011-01-01

    Laparoscopic ventral hernia repair has gained popularity among minimally invasive surgeons. However, mesh fixation remains a matter of discussion. This study was designed to compare noninvasive fibrin-glue attachment with tack fixation of meshes developed primarily for intra-abdominal use. It was hypothesized that particular mesh structures would substantially influence detachment force. For initial evaluation, specimens of laminated polypropylene/polydioxanone meshes were anchored to porcine abdominal walls by either helical titanium tacks or absorbable tacks in vitro. A universal tensile-testing machine was used to measure tangential detachment forces (TF). For subsequent experiments of glue fixation, polypropylene/polydioxanone mesh and 4 additional meshes with diverse particular mesh structure, ie, polyvinylidene fluoride/polypropylene mesh, a titanium-coated polypropylene mesh, a polyester mesh bonded with a resorbable collagen, and a macroporous condensed PTFE mesh were evaluated. TF tests revealed that fibrin-glue attachment was not substantially different from that achieved with absorbable tacks (median TF 7.8 Newton [N], range 1.3 to 15.8 N), but only when certain open porous meshes (polyvinylidene fluoride/polypropylene mesh: median 6.2 N, range 3.4 to 10.3 N; titanium-coated polypropylene mesh: median 5.2 N, range 2.1 to 11.7 N) were used. Meshes coated by an anti-adhesive barrier (polypropylene/polydioxanone mesh: median 3.1 N, range 1.7 to 5.8 N; polyester mesh bonded with a resorbable collagen: median 1.3 N, range 0.5 to 1.9 N), or the condensed PTFE mesh (median 3.1 N, range 2.1 to 7.0 N) provided a significantly lower TF (p < 0.01). Fibrin glue appears to be an appealing noninvasive option for mesh fixation in laparoscopic ventral hernia repair, but only if appropriate meshes are used. Glue can also serve as an adjunct to mechanical fixation to reduce the number of invasive tacks. Copyright © 2010 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Wound healing process and mediators: Implications for modulations for hernia repair and mesh integration.

    PubMed

    Sadava, Emmanuel E; Krpata, David M; Gao, Yue; Rosen, Michael J; Novitsky, Yuri W

    2014-01-01

    In recent years, major advances have been accomplished in abdominal wall reconstruction. Introduction of newer prostheses have improved outcomes, but elimination of mesh-related morbidity is still an elusive issue. It is believed that host foreign body reaction to prosthesis plays an important role in the biology of these complications, so understanding of the molecular mechanisms behind mesh-tissue interactions may be a key for upcoming therapies. It appears that increasing biocompatibility of both synthetic prosthesis and biologic scaffolds might be the main avenues to achieve better outcomes. This manuscript provides an overview of major effectors of wound healing with particular emphasis on how their modulation might improve outcomes in tissue remodeling and mesh integration. Copyright © 2013 Wiley Periodicals, Inc., a Wiley Company.

  20. Application of wall-models to discontinuous Galerkin LES

    NASA Astrophysics Data System (ADS)

    Frère, Ariane; Carton de Wiart, Corentin; Hillewaert, Koen; Chatelain, Philippe; Winckelmans, Grégoire

    2017-08-01

    Wall-resolved Large-Eddy Simulations (LES) are still limited to moderate Reynolds number flows due to the high computational cost required to capture the inner part of the boundary layer. Wall-modeled LES (WMLES) provide more affordable LES by modeling the near-wall layer. Wall function-based WMLES solve LES equations up to the wall, where the coarse mesh resolution essentially renders the calculation under-resolved. This makes the accuracy of WMLES very sensitive to the behavior of the numerical method. Therefore, best practice rules regarding the use and implementation of WMLES cannot be directly transferred from one methodology to another regardless of the type of discretization approach. Whilst numerous studies present guidelines on the use of WMLES, there is a lack of knowledge for discontinuous finite-element-like high-order methods. Incidentally, these methods are increasingly used on the account of their high accuracy on unstructured meshes and their strong computational efficiency. The present paper proposes best practice guidelines for the use of WMLES in these methods. The study is based on sensitivity analyses of turbulent channel flow simulations by means of a Discontinuous Galerkin approach. It appears that good results can be obtained without the use of a spatial or temporal averaging. The study confirms the importance of the wall function input data location and suggests to take it at the bottom of the second off-wall element. These data being available through the ghost element, the suggested method prevents the loss of computational scalability experienced in unstructured WMLES. The study also highlights the influence of the polynomial degree used in the wall-adjacent element. It should preferably be of even degree as using polynomials of degree two in the first off-wall element provides, surprisingly, better results than using polynomials of degree three.

  1. Smooth operator: The effects of different 3D mesh retriangulation protocols on the computation of Dirichlet normal energy.

    PubMed

    Spradley, Jackson P; Pampush, James D; Morse, Paul E; Kay, Richard F

    2017-05-01

    Dirichlet normal energy (DNE) is a metric of surface topography that has been used to evaluate the relationship between the surface complexity of primate cheek teeth and dietary categories. This study examines the effects of different 3D mesh retriangulation protocols on DNE. We examine how different protocols influence the DNE of a simple geometric shape-a hemisphere-to gain a more thorough understanding than can be achieved by investigating a complex biological surface such as a tooth crown. We calculate DNE on 3D surface meshes of hemispheres and on primate molars subjected to various retriangulation protocols, including smoothing algorithms, smoothing amounts, target face counts, and criteria for boundary face exclusion. Software used includes R, MorphoTester, Avizo, and MeshLab. DNE was calculated using the R package "molaR." In all cases, smoothing as performed in Avizo sharply decreases DNE initially, after which DNE becomes stable. Using a broader boundary exclusion criterion or performing additional smoothing (using "mesh fairing" methods) further decreases DNE. Increasing the mesh face count also results in increased DNE on tooth surfaces. Different retriangulation protocols yield different DNE values for the same surfaces, and should not be combined in meta-analyses. Increasing face count will capture surface microfeatures, but at the expense of computational speed. More aggressive smoothing is more likely to alter the essential geometry of the surface. A protocol is proposed that limits potential artifacts created during surface production while preserving pertinent features on the occlusal surface. © 2017 Wiley Periodicals, Inc.

  2. Axial Compression Behavior of a New Type of Prefabricated Concrete Sandwich Wall Panel

    NASA Astrophysics Data System (ADS)

    Qun, Xie; Shuai, Wang; Chun, Liu

    2018-03-01

    A novel type of prefabricated concrete sandwich wall panel which could be used as a load-bearing structural element in buildings has been presented in this paper. Compared with the traditional sandwich panels, there are several typical characteristics for this wall system, including core columns confined by spiral stirrup along the cross-section of panel with 600mm spacing, precast foamed concrete block between two structural layers as internal insulation part, and a three-dimensional (3D) steel wire skeleton in each layer which is composed of two vertical steel wire meshes connected by horizontally short steel bar. All steel segments in the panel are automatically prefabricated in factory and then are assembled to form steel system in site. In order to investigate the structural behavior of this wall panel, two full-scale panels have been experimentally studied under axial compressive load. The test results show that the wall panel presents good load-bearing capacity and integral stiffness without out-of-plane flexural failure. Compared to the panel with planar steel wire mesh in concrete layer, the panel with 3D steel wire skeleton presents higher strength and better rigidity even in the condition of same steel ratio in panels which verifies that the 3D steel skeleton could greatly enhance the structural behavior of sandwich panel.

  3. Finite Element in Angle Unit Sphere Meshing for Charged Particle Transport.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ortega, Mario Ivan; Drumm, Clifton R.

    Finite element in angle formulations of the charged particle transport equation require the discretization of the unit sphere. In Sceptre, a three-dimensional surface mesh of a sphere is transformed into a two-dimensional mesh. Projection of a sphere onto a two-dimensional surface is well studied with map makers spending the last few centuries attempting to create maps that preserve proportion and area. Using these techniques, various meshing schemes for the unit sphere were investigated.

  4. Using "Rebar" to Stabilize Rigid Chest Wall Reconstruction.

    PubMed

    Robinson, Lary A; Grubbs, Deanna M

    2016-04-01

    After major chest wall resection, reconstruction of the bony defect with a rigid prosthesis is mandatory to protect the underlying thoracic organs, and to prevent flail chest physiology. Although many methods have been described for chest wall reconstruction, a commonly used technique employs a composite Marlex (polypropylene) mesh with methyl-methacrylate cement sandwiched between two layers of mesh (MMS), which is tailored to the defect size and shape. In building construction, steel "rebar" is used to strengthen and reinforce masonry structures. To avoid the initial residual motion of the rigid prosthesis used to reconstruct very large defects, particularly the sternum, we devised a simple technique of adding one or more Steinmann steel pins as "rebar" to strengthen and immediately stabilize the prosthesis to the surrounding ribs and sternum. For the very large defects, particularly over the heart and great vessels, titanium mesh may also be readily added into the sandwich construction for increased strength and to prevent late prosthetic fractures. Short- and long-term results of this inexpensive modification of the MMS reconstruction technique are excellent. This modified MMS tailor-made prosthesis is only one-third the cost of the recently popular prosthetic titanium systems, takes much less operative time to create and implant, and avoids the well-described complications of late titanium bar fracture and erosion/infection as well as loosening of screws and/or titanium bars. Georg Thieme Verlag KG Stuttgart · New York.

  5. Post-operative pulmonary and shoulder function after sternal reconstruction for patients with chest wall sarcomas.

    PubMed

    Nishida, Yoshihiro; Tsukushi, Satoshi; Urakawa, Hiroshi; Toriyama, Kazuhiro; Kamei, Yuzuru; Yokoi, Kohei; Ishiguro, Naoki

    2015-12-01

    Sternal resection is occasionally required for patients with malignant tumors, particularly sarcomas, in the sternal region. Few reports have described post-operative respiratory and shoulder function after sternal resection for patients with bone and soft-tissue sarcomas. Eight consecutive patients with bone and soft tissue sarcomas requiring sternal resection were the focus of this study. Chest wall was reconstructed with a non-rigid or semi-rigid prosthesis combined, in most cases, with soft tissue flap reconstruction. Clinical outcomes investigated included complications, shoulder function, evaluated with Musculoskeletal Tumor Society-International Symposium of Limb Salvage system, and respiratory function, evaluated by use of spirometry. The anterior chest wall was reconstructed with non-rigid strings for 3 patients and with polypropylene mesh for 5. There were no severe post-operative complications, for example surgical site infection or pneumonia. All 3 patients with non-rigid reconstruction experienced paradoxical breathing, whereas none with polypropylene mesh did so. Post-operatively, FEV(1)% was unchanged but %VC was significantly reduced (p = 0.01), irrespective of the reconstruction method used (strings or polypropylene mesh). Shoulder function was not impaired. Among patients undergoing sternal resection, post-operative shoulder function was excellent. Pulmonary function was slightly restricted, but not sufficiently so to interfere with the activities of daily living (ADL). Paradoxical breathing is a slight concern for non-rigid reconstruction.

  6. Comparison of turbulence models and CFD solution options for a plain pipe

    NASA Astrophysics Data System (ADS)

    Canli, Eyub; Ates, Ali; Bilir, Sefik

    2018-06-01

    Present paper is partly a declaration of state of a currently ongoing PhD work about turbulent flow in a thick walled pipe in order to analyze conjugate heat transfer. An ongoing effort on CFD investigation of this problem using cylindrical coordinates and dimensionless governing equations is identified alongside a literature review. The mentioned PhD work will be conducted using an in-house developed code. However it needs preliminary evaluation by means of commercial codes available in the field. Accordingly ANSYS CFD was utilized in order to evaluate mesh structure needs and asses the turbulence models and solution options in terms of computational power versus difference signification. Present work contains a literature survey, an arrangement of governing equations of the PhD work, CFD essentials of the preliminary analysis and findings about the mesh structure and solution options. Mesh element number was changed between 5,000 and 320,000. k-ɛ, k-ω, Spalart-Allmaras and Viscous-Laminar models were compared. Reynolds number was changed between 1,000 and 50,000. As it may be expected due to the literature, k-ɛ yields more favorable results near the pipe axis and k-ωyields more convenient results near the wall. However k-ɛ is found sufficient to give turbulent structures for a conjugate heat transfer problem in a thick walled plain pipe.

  7. Note: Laser-cut molybdenum grids for a retarding field energy analyzer

    NASA Astrophysics Data System (ADS)

    Landheer, K.; Kobelev, A. A.; Smirnov, A. S.; Bosman, J.; Deelen, S.; Rossewij, M.; de Waal, A. C.; Poulios, I.; Benschop, A. F.; Schropp, R. E. I.; Rath, J. K.

    2017-06-01

    A retarding field energy analyzer (RFEA) with grids created by laser-cutting a honeycomb mesh in a 50 μm thick molybdenum foil is presented. The flat grids span an area of 1 cm2 and have high transmission (20 μm wide walls between 150 μm wide meshes). The molybdenum grids were tested in a 3-grid RFEA configuration with an analyzer depth of 0.87 mm.

  8. Surface modification of polypropylene mesh devices with cyclodextrin via cold plasma for hernia repair: Characterization and antibacterial properties

    NASA Astrophysics Data System (ADS)

    Sanbhal, Noor; Mao, Ying; Sun, Gang; Xu, Rui Fang; Zhang, Qian; Wang, Lu

    2018-05-01

    Light weight polypropylene (PP) mesh is the most widely used implant among all other synthetic meshes for hernia repair. However, infection is the complication associated to all synthetic meshes after hernia repair. Thus, to manage mesh related infection; antibacterial drug is generally loaded to surgical implants to supply drug locally in mesh implanted site. Nevertheless, PP mesh restricts the loading of antibacterial drug at operated area due to its low wettability. The aim of this study was to introduce a novel antimicrobial PP mesh modified with β-cyclodextrine (CD) and loaded with antimicrobial agent for infection prevention. A cold oxygen plasma treatment was able to activate the surfaces of polypropylene fibers, and then CD was incorporated onto the surfaces of PP fibers. Afterward, triclosan, as a model antibacterial agent, was loaded into CD cavity to provide desired antibacterial functions. The modified polypropylene mesh samples CD-Tric-1, CD-Tric-3 exhibited excellent inhibition zone and continuous antibacterial efficacy against E. coli and S. aureus up to 6 and 7 days respectively. Results of AFM, SEM, FTIR and antibacterial tests evidenced that oxygen plasma process is necessary to increase chemical connection between CD molecules and PP fibers. The samples were also characterized by using EDX, XRD, TGA, DSC and water contact angle.

  9. Finite element modeling of mass transport in high-Péclet cardiovascular flows

    NASA Astrophysics Data System (ADS)

    Hansen, Kirk; Arzani, Amirhossein; Shadden, Shawn

    2016-11-01

    Mass transport plays an important role in many important cardiovascular processes, including thrombus formation and atherosclerosis. These mass transport problems are characterized by Péclet numbers of up to 108, leading to several numerical difficulties. The presence of thin near-wall concentration boundary layers requires very fine mesh resolution in these regions, while large concentration gradients within the flow cause numerical stabilization issues. In this work, we will discuss some guidelines for solving mass transport problems in cardiovascular flows using a stabilized Galerkin finite element method. First, we perform mesh convergence studies in a series of idealized and patient-specific geometries to determine the required near-wall mesh resolution for these types of problems, using both first- and second-order tetrahedral finite elements. Second, we investigate the use of several boundary condition types at outflow boundaries where backflow during some parts of the cardiac cycle can lead to convergence issues. Finally, we evaluate the effect of reducing Péclet number by increasing mass diffusivity as has been proposed by some researchers. This work was supported by the NSF GRFP and NSF Career Award #1354541.

  10. Morphologic study of three collagen materials for body wall repair.

    PubMed

    Soiderer, Emily E; Lantz, Gary C; Kazacos, Evelyn A; Hodde, Jason P; Wiegand, Ryan E

    2004-05-15

    The search for ideal prostheses for body wall repair continues. Synthetic materials such as polypropylene mesh (PPM) are associated with healing complications. A porcine-derived collagen-based material (CBM), small intestinal submucosa (SIS), has been studied for body wall repair. Renal capsule matrix (RCM) and urinary bladder submucosa (UBS) are CBMs not previously evaluated in this application. This is the first implant study using RCM. Full-thickness muscle/fascia ventral abdominal wall defects were repaired with SIS, RCM, UBS, and PPM in rats with omentum and omentectomy. A random complete block design was used to allot implant type to each of 96 rats. Healing was evaluated at 4 and 8 weeks. Adhesion tenacity and surface area were scored. Implant site dimensions were measured at implantation and necropsy. Inflammation, vascularization, and fibrosis were histopathologically scored. Data were compared by analysis of variance (P < 0.05). PPM produced a granulomatous foreign body response in contrast to the organized healing of CBM implants. CBM mean scores were lower than PPM scores for adhesion tenacity, surface area, and inflammation at each follow-up time for rats with omentums (P < 0.02). The CBMs had less tenacity and inflammation than PPM at each follow-up time in omentectomy groups (P < 0.008). Wound contraction was greater for PPM (P < 0.0001) for all rats. RCM and UBS were similar to SIS invoking reduced inflammation, adhesion, and contraction compared to PPM. The fibrotic response to PPM was unique and more intense compared to CBMs. These CBM implants appear morphologically acceptable and warrant continued investigation.

  11. Modeling of influencing parameters in active noise control on an enclosure wall

    NASA Astrophysics Data System (ADS)

    Tarabini, Marco; Roure, Alain

    2008-04-01

    This paper investigates, by means of a numerical model, the possibility of using an active noise barrier to virtually reduce the acoustic transparency of a partition wall inside an enclosure. The room is modeled with the image method as a rectangular enclosure with a stationary point source; the active barrier is set up by an array of loudspeakers and error microphones and is meant to minimize the squared sound pressure on a wall with the use of a decentralized control. Simulations investigate the effects of the enclosure characteristics and of the barrier geometric parameters on the sound pressure attenuation on the controlled partition, on the whole enclosure potential energy and on the diagonal control stability. Performances are analyzed in a frequency range of 25-300 Hz at discrete 25 Hz steps. Influencing parameters and their effects on the system performances are identified with a statistical inference procedure. Simulation results have shown that it is possible to averagely reduce the sound pressure on the controlled partition. In the investigated configuration, the surface attenuation and the diagonal control stability are mainly driven by the distance between the loudspeakers and the error microphones and by the loudspeakers directivity; minor effects are due to the distance between the error microphones and the wall, by the wall reflectivity and by the active barrier grid meshing. Room dimensions and source position have negligible effects. Experimental results point out the validity of the model and the efficiency of the barrier in the reduction of the wall acoustic transparency.

  12. Self-assembled microstructures of confined rod-coil diblock copolymers by self-consistent field theory.

    PubMed

    Yang, Guang; Tang, Ping; Yang, Yuliang; Wang, Qiang

    2010-11-25

    We employ the self-consistent field theory (SCFT) incorporating Maier-Saupe orientational interactions between rods to investigate the self-assembly of rod-coil diblock copolymers (RC DBC) in bulk and especially confined into two flat surfaces in 2D space. A unit vector defined on a spherical surface for describing the orientation of rigid blocks in 3D Euclidean space is discretized with an icosahedron triangular mesh to numerically integrate over rod orientation, which is confirmed to have numerical accuracy and stability higher than that of the normal Gaussian quadrature. For the hockey puck-shaped phases in bulk, geometrical confinement, i.e., the film thickness, plays an important role in the self-assembled structures' transitions for the neutral walls. However, for the lamellar phase (monolayer smectic-C) in bulk, the perpendicular lamellae are always stable, less dependent on the film thicknesses because they can relax to the bulk spacing with less-paid coil-stretching in thin films. In particular, a very thin rod layer near the surfaces is formed even in a very thin film. When the walls prefer rods, parallel lamellae are obtained, strongly dependent on the competition between the degree of the surface fields and film geometrical confinement, and the effect of surface field on lamellar structure as a function of film thickness is investigated. Our simulation results provide a guide to understanding the self-assembly of the rod-coil films with desirable application prospects in the fabrication of organic light emitting devices.

  13. Assessment of adhesion formation after laparoscopic intraperitoneal implantation of Dynamesh IPOM mesh

    PubMed Central

    Jałyński, Marek; Piskorz, Łukasz; Brocki, Marian

    2013-01-01

    Introduction Formation of adhesions after laparoscopic hernia repair using the intra-peritoneal onlay mesh (IPOM) procedure can lead to intestinal obstruction or mesh erosion into intestinal lumen. The aims of this study included: measurement of adhesion formation with Dynamesh IPOM after laparoscopic intraperitoneal implantation, and assessment of the occurrence of isolated adhesions at the fastening sites of slowly absorbable sutures. Material and methods Twelve healthy pigs underwent laparoscopic implantation of 2 Dynamesh IPOM mesh fragments each, one was fastened with PDSII, and the other with Maxon sutures. An assessment of adhesion formation was carried out after 6 weeks and included an evaluation of surface area, hardness according to the Zhulke scale, and index values. The occurrence of isolated adhesions at slowly absorbable suture fixation points was also analyzed. Results Adhesions were noted in 83.3% of Dynamesh IPOM meshes. Adhesions covered on average 37.7% of the mesh surface with mean hardness 1.46 and index value 78.8. In groups fixed with PDS in comparison to Maxon sutures adhesions covered mean 31.6% vs. 42.5% (p = 0.62) of the mesh surface, mean hardness was 1.67 vs.1.25 (p = 0.34) and index 85.42 vs. 72.02 (p = 0.95). Conclusions The Dynamesh IPOM mesh, in spite of its anti-adhesive layer of PVDF, does not prevent the formation of adhesions. Adhesion hardness, surface area, and index values of the Dynamesh IPOM mesh are close to the mean values of these parameters for other commercially available 2-layer meshes. Slowly absorbable sutures used for fastening did not increase the risk of adhesion formation. PMID:23847671

  14. Numerical solution to the glancing sidewall oblique shock wave/turbulent boundary layer interaction in three dimension

    NASA Technical Reports Server (NTRS)

    Anderson, B. H.; Benson, T. J.

    1983-01-01

    A supersonic three-dimensional viscous forward-marching computer design code called PEPSIS is used to obtain a numerical solution of the three-dimensional problem of the interaction of a glancing sidewall oblique shock wave and a turbulent boundary layer. Very good results are obtained for a test case that was run to investigate the use of the wall-function boundary-condition approximation for a highly complex three-dimensional shock-boundary layer interaction. Two additional test cases (coarse mesh and medium mesh) are run to examine the question of near-wall resolution when no-slip boundary conditions are applied. A comparison with experimental data shows that the PEPSIS code gives excellent results in general and is practical for three-dimensional supersonic inlet calculations.

  15. Numerical solution to the glancing sidewall oblique shock wave/turbulent boundary layer interaction in three-dimension

    NASA Technical Reports Server (NTRS)

    Anderson, B. H.; Benson, T. J.

    1983-01-01

    A supersonic three-dimensional viscous forward-marching computer design code called PEPSIS is used to obtain a numerical solution of the three-dimensional problem of the interaction of a glancing sidewall oblique shock wave and a turbulent boundary layer. Very good results are obtained for a test case that was run to investigate the use of the wall-function boundary-condition approximation for a highly complex three-dimensional shock-boundary layer interaction. Two additional test cases (coarse mesh and medium mesh) are run to examine the question of near-wall resolution when no-slip boundary conditions are applied. A comparison with experimental data shows that the PEPSIS code gives excellent results in general and is practical for three-dimensional supersonic inlet calculations.

  16. Sphenoid dysplasia in neurofibromatosis type 1: a new technique for repair.

    PubMed

    Concezio, Di Rocco; Amir, Samii; Gianpiero, Tamburrini; Luca, Massimi; Mario, Giordano

    2017-06-01

    Sphenoid bone dysplasia in neurofibromatosis type 1 is characterized by progressive exophthalmos and facial disfiguration secondary to herniation of meningeal and cerebral structures. We describe a technique for reconstruction of the sphenoid defect apt at preventing or correcting the ocular globe dislocation. After placement of spinal cerebrospinal fluid drainage to reduce intracranial pressure, the temporal pole is posteriorly dislocated extradurally. The greater sphenoid wing defect is identified. A titanium mesh covered by lyophilized dura, modeled in a curved fashion, is interposed between the bone defect and the cerebro-meningeal structures with its convex surface over the retracted temporal pole. The particular configuration of the titanium mesh allows a self-maintaining position due to the pressure exerted by the brain over its convex central part with its lateral margins consequently pushed and self-anchored against the medial and lateral walls of the temporal fossa. Screw fixation is not needed. The technique utilized in four cases proved to be reliable at the long-term clinical and neuroradiological controls (6 to 19 years). Sphenoid bone dysplasia in NF1, resulting in proptosis and exophthalmos, is usually progressive. It can be surgically repaired using a curved titanium mesh with the convexity faced to the temporal pole that is in the opposite fashion from all the techniques previously introduced. When utilized early in life, the technique can prevent the occurrence of the orbital and facial disfiguration.

  17. A unified wall function for compressible turbulence modelling

    NASA Astrophysics Data System (ADS)

    Ong, K. C.; Chan, A.

    2018-05-01

    Turbulence modelling near the wall often requires a high mesh density clustered around the wall and the first cells adjacent to the wall to be placed in the viscous sublayer. As a result, the numerical stability is constrained by the smallest cell size and hence requires high computational overhead. In the present study, a unified wall function is developed which is valid for viscous sublayer, buffer sublayer and inertial sublayer, as well as including effects of compressibility, heat transfer and pressure gradient. The resulting wall function applies to compressible turbulence modelling for both isothermal and adiabatic wall boundary conditions with the non-zero pressure gradient. Two simple wall function algorithms are implemented for practical computation of isothermal and adiabatic wall boundary conditions. The numerical results show that the wall function evaluates the wall shear stress and turbulent quantities of wall adjacent cells at wide range of non-dimensional wall distance and alleviate the number and size of cells required.

  18. Evaluation of a new composite prosthesis for the repair of abdominal wall defects.

    PubMed

    Losi, Paola; Munaò, Antonella; Spiller, Dario; Briganti, Enrica; Martinelli, Ilaria; Scoccianti, Marco; Soldani, Giorgio

    2007-10-01

    The degree of integration of biomaterials used in the repair of abdominal wall defects seems to depend upon the structure of the prosthesis. The present investigation evaluates the behaviour in terms of adhesion formation and integration of a new composite prosthesis that could be employed in this clinical application. Full-thickness abdominal wall defects (7 x 5 cm) were created in 16 anaesthetized New Zealand white rabbits and the prosthesis were placed in direct contact with the visceral peritoneum during the experiment. The defects were repaired with a composite prosthesis or pure polypropylene mesh to establish two study groups (n = 8 each). The composite device was constituted by a polypropylene mesh physically attached to a poly(ether)urethane-polydimethylsiloxane laminar sheet. Animals were sacrificed 7, 14, 21 and 30 days after implant and prosthesis/surrounding tissue specimens subjected to light and electron microscopy. Firm adhesions were detected in the polypropylene implants, while they were not present in the composite implants. The excellent behaviour of the composite prosthesis shown in this study warrants further investigation on its use for the repair of abdominal wall defects when a prosthetic device needs to be placed in contact with the intestinal loops.

  19. Long term subjective cure rate, urinary tract symptoms and dyspareunia following mesh augmented anterior vaginal wall prolapse repair.

    PubMed

    Weintraub, A Y; Friedman, T; Baumfeld, Y; Neuman, M; Krissi, H

    2015-12-01

    The aim of this study was to assess patient-centered long term outcomes following anterior vaginal repair with mesh. In January 2015, we identified 124 women who underwent anterior pelvic floor repair with mesh between January 2006 and February 2009. Patient records were reviewed and demographic, clinical, intra-operative and post-operative follow-up data retrieved. Telephone interviews were conducted to access information on clinical outcomes. Associations between baseline characteristics and long term symptoms were assessed by multivariable logistic regression models. Seventy-nine women were reached and consented to participate. Patients were interviewed 79-104 months after surgery. Their mean age at the time of surgery was 62.48 ± 9.53 years; all had stage III cystocele with a mean POP Q point Ba of 5.32 ± 1.47. Twenty-four (30%) had a previous hysterectomy and 26 (33%) had a previous pelvic organ prolapse or stress urinary incontinence operation. At telephone interviews, recurrence of prolapse symptoms was reported by 11 (13.9%) patients, mostly in the posterior compartment. Only 6 needed a corrective procedure. One patient had her mesh removed due to dyspareunia. Eleven (13.9%) reported lower urinary tract symptoms other than prolapse, as follows: stress urinary incontinence (1), overactive bladder (8) and dyspareunia (2). Long term rates of recurrent prolapse, dyspareunia and lower urinary tract symptoms were low for patients who underwent anterior vaginal wall mesh augmentation surgery for symptomatic cystoceles. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  20. New Software Developments for Quality Mesh Generation and Optimization from Biomedical Imaging Data

    PubMed Central

    Yu, Zeyun; Wang, Jun; Gao, Zhanheng; Xu, Ming; Hoshijima, Masahiko

    2013-01-01

    In this paper we present a new software toolkit for generating and optimizing surface and volumetric meshes from three-dimensional (3D) biomedical imaging data, targeted at image-based finite element analysis of some biomedical activities in a single material domain. Our toolkit includes a series of geometric processing algorithms including surface re-meshing and quality-guaranteed tetrahedral mesh generation and optimization. All methods described have been encapsulated into a user-friendly graphical interface for easy manipulation and informative visualization of biomedical images and mesh models. Numerous examples are presented to demonstrate the effectiveness and efficiency of the described methods and toolkit. PMID:24252469

  1. Code and Solution Verification of 3D Numerical Modeling of Flow in the Gust Erosion Chamber

    NASA Astrophysics Data System (ADS)

    Yuen, A.; Bombardelli, F. A.

    2014-12-01

    Erosion microcosms are devices commonly used to investigate the erosion and transport characteristics of sediments at the bed of rivers, lakes, or estuaries. In order to understand the results these devices provide, the bed shear stress and flow field need to be accurately described. In this research, the UMCES Gust Erosion Microcosm System (U-GEMS) is numerically modeled using Finite Volume Method. The primary aims are to simulate the bed shear stress distribution at the surface of the sediment core/bottom of the microcosm, and to validate the U-GEMS produces uniform bed shear stress at the bottom of the microcosm. The mathematical model equations are solved by on a Cartesian non-uniform grid. Multiple numerical runs were developed with different input conditions and configurations. Prior to developing the U-GEMS model, the General Moving Objects (GMO) model and different momentum algorithms in the code were verified. Code verification of these solvers was done via simulating the flow inside the top wall driven square cavity on different mesh sizes to obtain order of convergence. The GMO model was used to simulate the top wall in the top wall driven square cavity as well as the rotating disk in the U-GEMS. Components simulated with the GMO model were rigid bodies that could have any type of motion. In addition cross-verification was conducted as results were compared with numerical results by Ghia et al. (1982), and good agreement was found. Next, CFD results were validated by simulating the flow within the conventional microcosm system without suction and injection. Good agreement was found when the experimental results by Khalili et al. (2008) were compared. After the ability of the CFD solver was proved through the above code verification steps. The model was utilized to simulate the U-GEMS. The solution was verified via classic mesh convergence study on four consecutive mesh sizes, in addition to that Grid Convergence Index (GCI) was calculated and based on that the computation uncertainty was quantified. The numerical results reveal that the bed shear stress distribution for the U-GEMS model was not uniform. The mean and standard deviation of the bed shear stress for the U-GEMS model was 0.04 and 0.019 Pa respectively.

  2. A Comparative Study of Four Impedance Eduction Methodologies Using Several Test Liners

    NASA Technical Reports Server (NTRS)

    Watson, Willie R.; Jones, Michael G.

    2013-01-01

    A comparative study of four commonly used impedance eduction methods is presented for a range of liner structures and test conditions. Two of the methods are restricted to uniform flow while the other two accommodate both uniform and boundary layer flows. Measurements on five liner structures (a rigid-wall insert, a ceramic tubular liner, a wire mesh liner, a low porosity conventional liner, and a high porosity conventional liner) are obtained using the NASA Langley Grazing Flow Impedance Tube. The educed impedance of each liner is presented for forty-two test conditions (three Mach numbers and fourteen frequencies). In addition, the effects of moving the acoustic source from upstream to downstream and the refractive effects of the mean boundary layer on the wire mesh liner are investigated. The primary conclusions of the study are that: (1) more accurate results are obtained for the upstream source, (2) the uniform flow methods produce nearly identical impedance spectra at and below Mach 0.3 but significant scatter in the educed impedance occurs at the higher Mach number, (3) there is better agreement in educed impedance among the methods for the conventional liners than for the rigid-wall insert, ceramic, or wire mesh liner, and (4) the refractive effects of the mean boundary layer on the educed impedance of the wire mesh liner are generally small except at Mach 0.5.

  3. Learning-based 3D surface optimization from medical image reconstruction

    NASA Astrophysics Data System (ADS)

    Wei, Mingqiang; Wang, Jun; Guo, Xianglin; Wu, Huisi; Xie, Haoran; Wang, Fu Lee; Qin, Jing

    2018-04-01

    Mesh optimization has been studied from the graphical point of view: It often focuses on 3D surfaces obtained by optical and laser scanners. This is despite the fact that isosurfaced meshes of medical image reconstruction suffer from both staircases and noise: Isotropic filters lead to shape distortion, while anisotropic ones maintain pseudo-features. We present a data-driven method for automatically removing these medical artifacts while not introducing additional ones. We consider mesh optimization as a combination of vertex filtering and facet filtering in two stages: Offline training and runtime optimization. In specific, we first detect staircases based on the scanning direction of CT/MRI scanners, and design a staircase-sensitive Laplacian filter (vertex-based) to remove them; and then design a unilateral filtered facet normal descriptor (uFND) for measuring the geometry features around each facet of a given mesh, and learn the regression functions from a set of medical meshes and their high-resolution reference counterparts for mapping the uFNDs to the facet normals of the reference meshes (facet-based). At runtime, we first perform staircase-sensitive Laplacian filter on an input MC (Marching Cubes) mesh, and then filter the mesh facet normal field using the learned regression functions, and finally deform it to match the new normal field for obtaining a compact approximation of the high-resolution reference model. Tests show that our algorithm achieves higher quality results than previous approaches regarding surface smoothness and surface accuracy.

  4. Comparison and Computational Performance of Tsunami-HySEA and MOST Models for the LANTEX 2013 scenario

    NASA Astrophysics Data System (ADS)

    González-Vida, Jose M.; Macías, Jorge; Mercado, Aurelio; Ortega, Sergio; Castro, Manuel J.

    2017-04-01

    Tsunami-HySEA model is used to simulate the Caribbean LANTEX 2013 scenario (LANTEX is the acronym for Large AtlaNtic Tsunami EXercise, which is carried out annually). The numerical simulation of the propagation and inundation phases, is performed with both models but using different mesh resolutions and nested meshes. Some comparisons with the MOST tsunami model available at the University of Puerto Rico (UPR) are made. Both models compare well for propagating tsunami waves in open sea, producing very similar results. In near-shore shallow waters, Tsunami-HySEA should be compared with the inundation version of MOST, since the propagation version of MOST is limited to deeper waters. Regarding the inundation phase, a 1 arc-sec (approximately 30 m) resolution mesh covering all of Puerto Rico, is used, and a three-level nested meshes technique implemented. In the inundation phase, larger differences between model results are observed. Nevertheless, the most striking difference resides in computational time; Tsunami-HySEA is coded using the advantages of GPU architecture, and can produce a 4 h simulation in a 60 arcsec resolution grid for the whole Caribbean Sea in less than 4 min with a single general-purpose GPU and as fast as 11 s with 32 general-purpose GPUs. In the inundation stage with nested meshes, approximately 8 hours of wall clock time is needed for a 2-h simulation in a single GPU (versus more than 2 days for the MOST inundation, running three different parts of the island—West, Center, East—at the same time due to memory limitations in MOST). When domain decomposition techniques are finally implemented by breaking up the computational domain into sub-domains and assigning a GPU to each sub-domain (multi-GPU Tsunami-HySEA version), we show that the wall clock time significantly decreases, allowing high-resolution inundation modelling in very short computational times, reducing, for example, if eight GPUs are used, the wall clock time to around 1 hour. Besides, these computational times are obtained using general-purpose GPU hardware.

  5. [Development of better tolerated prosthetic materials: applications in gynecological surgery].

    PubMed

    Debodinance, P; Delporte, P; Engrand, J B; Boulogne, M

    2002-10-01

    Meshes have come to be widely used for surgical repair of the dysfunctional pelvic floor. The problem to date has been mesh intolerance. History. The first meshes were made with silver filigrees or stainless steel. Non-metallic and non-absorbable synthetic prostheses include nylon, silastic, polytetrafluoroethylene as well as expansive polyester and polypropylene forms. Most of the absorbable prostheses are made of polyglycolic acid and polyglactine 910. Classification. Four groups of biomaterials can be described according to pore size. Mechanical and biological properties. The mechanical properties of meshes have been tested industrially for resistance, pliability, elasticity and ductile qualities. These properties depend on type of tissue structure (woven or knitted) and the type of fiber used (mono and multi-filaments). The goal is to obtain a "silent" material, i.e. a material which does not trigger a host tissue reaction. Introducing the foreign body induces a "scarring" response. This fibroblastic reaction replaces the inflammatory reaction, leading to progressive colonization of the prosthesis. The major risk is infection caused by a disturbance of the inflammatory phase and bacterial development. Bacteria can be trapped in fibrotic tissue, with the risk of delayed infection. Immunological reactions may have an additive effect. These problems are not encountered with absorbable meshes. An ideal implant material must: not undergo physical modification by tissue fluids, be chemically inert, not trigger inflammatory or foreign body cell response in body tissues, be noncarcinogenic and nonallergenic, be capable of resisting mechanical stress and sterilization, and be able to be manufactured in the necessary shape. Polyester, polypropylene and expansive polytetrafluoroethylene fulfill these criteria. The ideal mesh. Eleven criteria are proposed. Complications for hernia repair. Infection and seroma are the most frequent complications with micro-porous meshes. Macro-porous meshes can cause erosive phenomena and adhesions. Retraction of synthetic tissues is observed in 20 to 30% of cases. Meshes in gynecology. In gynecology surgery, meshes made their first appearance in trans-abdominal sacrocolpopexy and slings. A detailed review of complications found in 32 articles studying slings and 22 studying sacrocolpopexy with approximately 10 types of meshes shows that intolerance of slings has oscillated between 1% with Prolene and 31% with Gore-Tex; for abdominal sacrocolpopexy the rate was between 1.7% with Prolene and 20% with Teflon. Rejection phenomena appear during the first year and are proportional to the surface area of the synthetic tissue and the proximity of the vaginal scar. New materials have been proposed over the last ten years for prolapse surgery, notably for cystocele, which accounts for 70% of all repair procedures. Nearly fifteen studies have reported a level of intolerance reaching 6%, the large majority of the meshes used being Prolene meshes. Our personal experience with 87 repair procedures has led us to the conclusion that Prolene is the most adapted mesh, allowing free tension between the bladder and the anterior vaginal wall. Continuous evaluation is needed to study these replacement materials which should in theory, improve the rate of recurrence, which is at present 20% with classic procedures not using a mesh.

  6. Molecular surface mesh generation by filtering electron density map.

    PubMed

    Giard, Joachim; Macq, Benoît

    2010-01-01

    Bioinformatics applied to macromolecules are now widely spread and in continuous expansion. In this context, representing external molecular surface such as the Van der Waals Surface or the Solvent Excluded Surface can be useful for several applications. We propose a fast and parameterizable algorithm giving good visual quality meshes representing molecular surfaces. It is obtained by isosurfacing a filtered electron density map. The density map is the result of the maximum of Gaussian functions placed around atom centers. This map is filtered by an ideal low-pass filter applied on the Fourier Transform of the density map. Applying the marching cubes algorithm on the inverse transform provides a mesh representation of the molecular surface.

  7. The 3-D unstructured mesh generation using local transformations

    NASA Technical Reports Server (NTRS)

    Barth, Timothy J.

    1993-01-01

    The topics are presented in viewgraph form and include the following: 3D combinatorial edge swapping; 3D incremental triangulation via local transformations; a new approach to multigrid for unstructured meshes; surface mesh generation using local transforms; volume triangulations; viscous mesh generation; and future directions.

  8. Combining 3d Volume and Mesh Models for Representing Complicated Heritage Buildings

    NASA Astrophysics Data System (ADS)

    Tsai, F.; Chang, H.; Lin, Y.-W.

    2017-08-01

    This study developed a simple but effective strategy to combine 3D volume and mesh models for representing complicated heritage buildings and structures. The idea is to seamlessly integrate 3D parametric or polyhedral models and mesh-based digital surfaces to generate a hybrid 3D model that can take advantages of both modeling methods. The proposed hybrid model generation framework is separated into three phases. Firstly, after acquiring or generating 3D point clouds of the target, these 3D points are partitioned into different groups. Secondly, a parametric or polyhedral model of each group is generated based on plane and surface fitting algorithms to represent the basic structure of that region. A "bare-bones" model of the target can subsequently be constructed by connecting all 3D volume element models. In the third phase, the constructed bare-bones model is used as a mask to remove points enclosed by the bare-bones model from the original point clouds. The remaining points are then connected to form 3D surface mesh patches. The boundary points of each surface patch are identified and these boundary points are projected onto the surfaces of the bare-bones model. Finally, new meshes are created to connect the projected points and original mesh boundaries to integrate the mesh surfaces with the 3D volume model. The proposed method was applied to an open-source point cloud data set and point clouds of a local historical structure. Preliminary results indicated that the reconstructed hybrid models using the proposed method can retain both fundamental 3D volume characteristics and accurate geometric appearance with fine details. The reconstructed hybrid models can also be used to represent targets in different levels of detail according to user and system requirements in different applications.

  9. Mesh infrastructure for coupled multiprocess geophysical simulations

    DOE PAGES

    Garimella, Rao V.; Perkins, William A.; Buksas, Mike W.; ...

    2014-01-01

    We have developed a sophisticated mesh infrastructure capability to support large scale multiphysics simulations such as subsurface flow and reactive contaminant transport at storage sites as well as the analysis of the effects of a warming climate on the terrestrial arctic. These simulations involve a wide range of coupled processes including overland flow, subsurface flow, freezing and thawing of ice rich soil, accumulation, redistribution and melting of snow, biogeochemical processes involving plant matter and finally, microtopography evolution due to melting and degradation of ice wedges below the surface. In addition to supporting the usual topological and geometric queries about themore » mesh, the mesh infrastructure adds capabilities such as identifying columnar structures in the mesh, enabling deforming of the mesh subject to constraints and enabling the simultaneous use of meshes of different dimensionality for subsurface and surface processes. The generic mesh interface is capable of using three different open source mesh frameworks (MSTK, MOAB and STKmesh) under the hood allowing the developers to directly compare them and choose one that is best suited for the application's needs. We demonstrate the results of some simulations using these capabilities as well as present a comparison of the performance of the different mesh frameworks.« less

  10. Resistive-force theory for mesh-like superhydrophobic surfaces

    NASA Astrophysics Data System (ADS)

    Schnitzer, Ory; Yariv, Ehud

    2018-03-01

    A common realization of superhydrophobic surfaces makes use of a mesh-like geometry, where pockets of air are trapped in a periodic array of holes in a no-slip solid substrate. We consider the small-solid-fraction limit where the ribs of the mesh are narrow. In this limit, we obtain a simple leading-order approximation for the slip-length tensor of an arbitrary mesh geometry. This approximation scales as the solid-fraction logarithm, as anticipated by Ybert et al. [Phys. Fluids 19, 123601 (2007), 10.1063/1.2815730]; in the special case of a square mesh it agrees with the analytical results obtained by Davis and Lauga [Phys. Fluids 21, 113101 (2009), 10.1063/1.3250947].

  11. New software developments for quality mesh generation and optimization from biomedical imaging data.

    PubMed

    Yu, Zeyun; Wang, Jun; Gao, Zhanheng; Xu, Ming; Hoshijima, Masahiko

    2014-01-01

    In this paper we present a new software toolkit for generating and optimizing surface and volumetric meshes from three-dimensional (3D) biomedical imaging data, targeted at image-based finite element analysis of some biomedical activities in a single material domain. Our toolkit includes a series of geometric processing algorithms including surface re-meshing and quality-guaranteed tetrahedral mesh generation and optimization. All methods described have been encapsulated into a user-friendly graphical interface for easy manipulation and informative visualization of biomedical images and mesh models. Numerous examples are presented to demonstrate the effectiveness and efficiency of the described methods and toolkit. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  12. Assessment of adhesion formation to intra-abdominal polypropylene mesh and polytetrafluoroethylene mesh.

    PubMed

    Matthews, Brent D; Pratt, Broc L; Pollinger, Harrison S; Backus, Charles L; Kercher, Kent W; Sing, R F; Heniford, B Todd

    2003-10-01

    The development of intra-abdominal adhesions, bowel obstruction, and enterocutaneous fistulas are potentially severe complications related to the intraperitoneal placement of prosthetic biomaterials. The purpose of this study was to determine the natural history of adhesion formation to polypropylene mesh and two types of polytetrafluoroethylene (ePTFE) mesh when placed intraperitoneally in a rabbit model that simulates laparoscopic ventral hernia repair. Thirty New Zealand white rabbits were used for this study. A 10-cm midline incision was performed for intra-abdominal access and a 2 cm x 2 cm piece of mesh (n = 60) was sewn to an intact peritoneum on each side of the midline. Two types of ePTFE mesh (Dual Mesh and modified Dual Mesh, W.L. Gore & Assoc., Flagstaff, AZ) and polypropylene mesh were compared. The rate of adhesion formation was evaluated by direct visualization using microlaparoscopy (2-mm endoscope/trocar) at 7 days, 3 weeks, 9 weeks, and 16 weeks after mesh implantation. Adhesions to the prosthetic mesh were scored for extent (%) using the Modified Diamond Scale (0 = 0%, 1 50%). At necropsy the mesh was excised en bloc with the anterior abdominal wall for histological evaluation of mesothelial layer growth. The mean adhesion score for the polypropylene mesh was significantly greater (P < 0.05) than Dual Mesh at 9 weeks and 16 weeks and modified Dual Mesh at 7 days, 9 weeks, and 16 weeks. Fifty-five percent (n = 11) of the polypropylene mesh had adhesions to small intestine or omentum at necropsy compared to 30% (n = 6) of the Dual Mesh and 20% (n = 4) of the modified Dual Mesh. There was a significantly greater percentage (P < 0.003) of ePTFE mesh mesothelialized at explant (modified Dual Mesh 44.2%; Dual Mesh 55.8%) compared to the polypropylene mesh (12.9%). Serial microlaparoscopic evaluation of intraperitoneally implanted polypropylene mesh and ePTFE mesh in a rabbit model revealed a progression of adhesions to polypropylene mesh over a 16 week period. The pore size of mesh is critical in the development and maintenance of abdominal adhesions and tissue ingrowth. The macroporous polypropylene mesh promoted adhesion formation, while the microporous nature of the visceral side of the ePTFE served as a barrier to adhesions.

  13. Low-cost exterior insulation process and structure

    DOEpatents

    Vohra, A.

    1999-03-02

    A low-cost exterior insulation process of stacking bags of insulating material against a wall and covering them with wire mesh and stucco provides a durable structure with good insulating value. 2 figs.

  14. Self-organization of human iPS cells into trophectoderm mimicking cysts induced by adhesion restriction using microstructured mesh scaffolds.

    PubMed

    Okeyo, Kennedy O; Tanabe, Maiko; Kurosawa, Osamu; Oana, Hidehiro; Washizu, Masao

    2018-04-01

    Cellular dynamics leading to the formation of the trophectoderm in humans remain poorly understood owing to limited accessibility to human embryos for research into early human embryogenesis. Compared to animal models, organoids formed by self-organization of stem cells in vitro may provide better insights into differentiation and complex morphogenetic processes occurring during early human embryogenesis. Here we demonstrate that modulating the cell culture microenvironment alone can trigger self-organization of human induced pluripotent stem cells (hiPSCs) to yield trophectoderm-mimicking cysts without chemical induction. To modulate the adhesion microenvironment, we used the mesh culture technique recently developed by our group, which involves culturing hiPSCs on suspended micro-structured meshes with limited surface area for cell adhesion. We show that this adhesion-restriction strategy can trigger a two-stage self-organization of hiPSCs; first into stem cell sheets, which express pluripotency signatures until around day 8-10, then into spherical cysts following differentiation and self-organization of the sheet-forming cells. Detailed morphological analysis using immunofluorescence microscopy with both confocal and two-photon microscopes revealed the anatomy of the cysts as consisting of a squamous epithelial wall richly expressing E-cadherin and CDX2. We also confirmed that the cysts exhibit a polarized morphology with basal protrusions, which show migratory behavior when anchored. Together, our results point to the formation of cysts which morphologically resemble the trophectoderm at the late-stage blastocyst. Thus, the mesh culture microenvironment can initiate self-organization of hiPSCs into trophectoderm-mimicking cysts as organoids with potential application in the study of early embryogenesis and also in drug development. © 2018 Japanese Society of Developmental Biologists.

  15. Thermographic inspection of external thermal insulation systems with mechanical fixing

    NASA Astrophysics Data System (ADS)

    Simões, Nuno; Simões, Inês; Serra, Catarina; Tadeu, António

    2015-05-01

    An External Thermal Insulation Composite System (ETICS) kit may include anchors to mechanically fix the insulation product onto the wall. Using this option increases safety when compared to a simple bonded solution, however, it is more expensive and needs higher labor resources. The insulation product is then coated with rendering, which applied to the insulation material without any air gap. The rendering comprises one or more layers of coats with an embedded reinforcement. The most common multi-coat rendering system presents a base coat applied directly to the insulation product with a glass fiber mesh as reinforcement, followed by a second base coat, before a very thin coat (key coat) that prepares the surface to receive the finishing and decorative coat. The thickness of the rendering system may vary between around 5 to 10 mm. The higher thicknesses may be associated with a reinforcement composed by two layers of glass fiber mesh. The main purpose of this work is to apply infrared thermography (IRT) techniques to 2 ETICS solution (single or double layer of glass fiber mesh) and evaluate its capability in the detection of anchors. The reliability of IRT was tested using an ETICS configuration of expanded cork boards and a rendering system with one or two layers of glass fiber mesh. An active thermography approach was performed in laboratory conditions, in transmission and reflection mode. In the reflection mode halogen lamps and air heater were employed as the thermal stimulus. Air heater was also the source used in the transmission mode tests. The resulting data was processed in both time and frequency domains. In this last approach, phase contrast images were generated and studied.

  16. Hemodynamics model of fluid–solid interaction in internal carotid artery aneurysms

    PubMed Central

    Fu-Yu, Wang; Lei, Liu; Xiao-Jun, Zhang; Hai-Yue, Ju

    2010-01-01

    The objective of this study is to present a relatively simple method to reconstruct cerebral aneurysms as 3D numerical grids. The method accurately duplicates the geometry to provide computer simulations of the blood flow. Initial images were obtained by using CT angiography and 3D digital subtraction angiography in DICOM format. The image was processed by using MIMICS software, and the 3D fluid model (blood flow) and 3D solid model (wall) were generated. The subsequent output was exported to the ANSYS workbench software to generate the volumetric mesh for further hemodynamic study. The fluid model was defined and simulated in CFX software while the solid model was calculated in ANSYS software. The force data calculated firstly in the CFX software were transferred to the ANSYS software, and after receiving the force data, total mesh displacement data were calculated in the ANSYS software. Then, the mesh displacement data were transferred back to the CFX software. The data exchange was processed in workbench software. The results of simulation could be visualized in CFX-post. Two examples of grid reconstruction and blood flow simulation for patients with internal carotid artery aneurysms were presented. The wall shear stress, wall total pressure, and von Mises stress could be visualized. This method seems to be relatively simple and suitable for direct use by neurosurgeons or neuroradiologists, and maybe a practical tool for planning treatment and follow-up of patients after neurosurgical or endovascular interventions with 3D angiography. PMID:20812022

  17. Hemodynamics model of fluid-solid interaction in internal carotid artery aneurysms.

    PubMed

    Bai-Nan, Xu; Fu-Yu, Wang; Lei, Liu; Xiao-Jun, Zhang; Hai-Yue, Ju

    2011-01-01

    The objective of this study is to present a relatively simple method to reconstruct cerebral aneurysms as 3D numerical grids. The method accurately duplicates the geometry to provide computer simulations of the blood flow. Initial images were obtained by using CT angiography and 3D digital subtraction angiography in DICOM format. The image was processed by using MIMICS software, and the 3D fluid model (blood flow) and 3D solid model (wall) were generated. The subsequent output was exported to the ANSYS workbench software to generate the volumetric mesh for further hemodynamic study. The fluid model was defined and simulated in CFX software while the solid model was calculated in ANSYS software. The force data calculated firstly in the CFX software were transferred to the ANSYS software, and after receiving the force data, total mesh displacement data were calculated in the ANSYS software. Then, the mesh displacement data were transferred back to the CFX software. The data exchange was processed in workbench software. The results of simulation could be visualized in CFX-post. Two examples of grid reconstruction and blood flow simulation for patients with internal carotid artery aneurysms were presented. The wall shear stress, wall total pressure, and von Mises stress could be visualized. This method seems to be relatively simple and suitable for direct use by neurosurgeons or neuroradiologists, and maybe a practical tool for planning treatment and follow-up of patients after neurosurgical or endovascular interventions with 3D angiography.

  18. The UK National Prolapse Survey: 10 years on.

    PubMed

    Jha, Swati; Cutner, Alfred; Moran, Paul

    2018-06-01

    To assess trends in the surgical management of pelvic organ prolapse (POP) amongst UK practitioners and changes in practice since a previous similar survey. An online questionnaire survey (Typeform Pro) was emailed to British Society of Urogynaecology (BSUG) members. They included urogynaecologists working in tertiary centres, gynaecologists with a designated special interest in urogynaecology and general gynaecologists. The questionnaire included case scenarios encompassing contentious issues in the surgical management of POP and was a revised version of the questionnaire used in the previous surveys. The revised questionnaire included additional questions relating to the use of vaginal mesh and laparoscopic urogynaecology procedures. Of 516 BSUG members emailed, 212 provided completed responses.. For anterior vaginal wall prolapse the procedure of choice was anterior colporrhaphy (92% of respondents). For uterovaginal prolapse the procedure of choice was still vaginal hysterectomy and repair (75%). For posterior vaginal wall prolapse the procedure of choice was posterior colporrhaphy with midline fascial plication (97%). For vault prolapse the procedure of choice was sacrocolpopexy (54%) followed by vaginal wall repair and sacrospinous fixation (41%). The laparoscopic route was preferred for sacrocolpopexy (62% versus 38% for the open procedure). For primary prolapse, vaginal mesh was used by only 1% of respondents in the anterior compartment and by 3% in the posterior compartment. Basic trends in the use of native tissue prolapse surgery remain unchanged. There has been a significant decrease in the use of vaginal mesh for both primary and recurrent prolapse, with increasing use of laparoscopic procedures for prolapse.

  19. Vertical exploration and dimensional modularity in mice

    PubMed Central

    Benjamini, Yoav; Golani, Ilan

    2018-01-01

    Exploration is a central component of animal behaviour studied extensively in rodents. Previous tests of free exploration limited vertical movement to rearing and jumping. Here, we attach a wire mesh to the arena wall, allowing vertical exploration. This provides an opportunity to study the morphogenesis of behaviour along the vertical dimension, and examine the context in which it is performed. In the current set-up, the mice first use the doorway as a point reference for establishing a borderline linear path along the circumference of the arena floor, and then use this path as a linear reference for performing horizontal forays towards the centre (incursions) and vertical forays on the wire mesh (ascents). Vertical movement starts with rearing on the wall, and commences with straight vertical ascents that increase in extent and complexity. The mice first reach the top of the wall, then mill about within circumscribed horizontal sections, and then progress horizontally for increasingly longer distances on the upper edge of the wire mesh. Examination of the sequence of borderline segments, incursions and ascents reveals dimensional modularity: an initial series (bout) of borderline segments precedes alternating bouts of incursions and bouts of ascents, thus exhibiting sustained attention to each dimension separately. The exhibited separate growth in extent and in complexity of movement and the sustained attention to each of the three dimensions disclose the mice's modular perception of this environment and validate all three as natural kinds. PMID:29657827

  20. Tooth-meshing-harmonic static-transmission-error amplitudes of helical gears

    NASA Astrophysics Data System (ADS)

    Mark, William D.

    2018-01-01

    The static transmission errors of meshing gear pairs arise from deviations of loaded tooth working surfaces from equispaced perfect involute surfaces. Such deviations consist of tooth-pair elastic deformations and geometric deviations (modifications) of tooth working surfaces. To a very good approximation, the static-transmission-error tooth-meshing-harmonic amplitudes of helical gears are herein expressed by superposition of Fourier transforms of the quantities: (1) the combination of tooth-pair elastic deformations and geometric tooth-pair modifications and (2) fractional mesh-stiffness fluctuations, each quantity (1) and (2) expressed as a function of involute "roll distance." Normalization of the total roll-distance single-tooth contact span to unity allows tooth-meshing-harmonic amplitudes to be computed for different shapes of the above-described quantities (1) and (2). Tooth-meshing harmonics p = 1, 2, … are shown to occur at Fourier-transform harmonic values of Qp, p = 1, 2, …, where Q is the actual (total) contact ratio, thereby verifying its importance in minimizing transmission-error tooth-meshing-harmonic amplitudes. Two individual shapes and two series of shapes of the quantities (1) and (2) are chosen to illustrate a wide variety of shapes. In most cases representative of helical gears, tooth-meshing-harmonic values p = 1, 2, … are shown to occur in Fourier-transform harmonic regions governed by discontinuities arising from tooth-pair-contact initiation and termination, thereby showing the importance of minimizing such discontinuities. Plots and analytical expressions for all such Fourier transforms are presented, thereby illustrating the effects of various types of tooth-working-surface modifications and tooth-pair stiffnesses on transmission-error generation.

  1. Full Wave Analysis of RF Signal Attenuation in a Lossy Rough Surface Cave using a High Order Time Domain Vector Finite Element Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pingenot, J; Rieben, R; White, D

    2005-10-31

    We present a computational study of signal propagation and attenuation of a 200 MHz planar loop antenna in a cave environment. The cave is modeled as a straight and lossy random rough wall. To simulate a broad frequency band, the full wave Maxwell equations are solved directly in the time domain via a high order vector finite element discretization using the massively parallel CEM code EMSolve. The numerical technique is first verified against theoretical results for a planar loop antenna in a smooth lossy cave. The simulation is then performed for a series of random rough surface meshes in ordermore » to generate statistical data for the propagation and attenuation properties of the antenna in a cave environment. Results for the mean and variance of the power spectral density of the electric field are presented and discussed.« less

  2. Biomechanical and histologic evaluation of two application forms of surgical glue for mesh fixation to the abdominal wall.

    PubMed

    Ortillés, Á; Pascual, G; Peña, E; Rodríguez, M; Pérez-Köhler, B; Mesa-Ciller, C; Calvo, B; Bellón, J M

    2017-11-01

    The use of an adhesive for mesh fixation in hernia repair reduces chronic pain and minimizes tissue damage in the patient. This study was designed to assess the adhesive properties of a medium-chain (n-butyl) cyanoacrylate glue applied as drops or as a spray in a biomechanical and histologic study. Both forms of glue application were compared to the use of simple-loose or continuous-running polypropylene sutures for mesh fixation. Eighteen adult New Zealand White rabbits were used. For mechanical tests in an ex vivo and in vivo study, patches of polypropylene mesh were fixed to an excised fragment of healthy abdominal tissue or used to repair a partial abdominal wall defect in the rabbit respectively. Depending on the fixation method used, four groups of 12 implants each or 10 implants each respectively for the ex vivo and in vivo studies were established: Glue-Drops, Glue-Spray, Suture-Simple and Suture-Continuous. Biomechanical resistance in the ex vivo implants was tested five minutes after mesh fixation. In vivo implants for biomechanical and histologic assessment were collected at 14 days postimplant. In the ex vivo study, the continuous suture implants showed the highest failure sample tension, while the implants fixed with glue showed lower failure sample tension values. However, the simple and continuous suture implants returned the highest stretch values. In the in vivo implants, failure sample tension values were similar among groups while the implants fixed with a continuous running suture had the higher stretch values, and the glue-fixed implants the lower stretch values. All meshes showed good tissue integration within the host tissue regardless of the fixation method used. Our histologic study revealed the generation of a denser, more mature repair tissue when the cyanoacrylate glue was applied as a spray rather than as drops. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Prophylactic Mesh Reinforcement versus Sutured Closure to Prevent Incisional Hernias after Open Abdominal Aortic Aneurysm Repair via Midline Laparotomy: A Systematic Review and Meta-Analysis.

    PubMed

    Indrakusuma, Reza; Jalalzadeh, Hamid; van der Meij, Jessica E; Balm, Ron; Koelemay, Mark J W

    2018-04-20

    Incisional hernia is a frequent late complication after open abdominal aortic aneurysm (AAA) repair. We aimed to determine whether prophylactic mesh reinforcement of the abdominal wall at open AAA repair via midline laparotomy reduces the rate of incisional hernia compared to standard sutured closure. A systematic review and meta-analysis was carried out in accordance with the PRISMA statement (PROSPERO registration CRD42017072508). Randomised controlled trials (RCTs) comparing prophylactic mesh reinforcement with standard sutured closure were eligible for inclusion. MEDLINE, Embase, and the Cochrane Library were searched. A meta-analysis with a random effects model was carried out to estimate pooled risk ratios (RR) with 95% confidence intervals (CIs) for the incidence of, and re-operation rate for, incisional hernias. Assessments of methodological quality, quality of evidence, and strength of recommendations were done with the Cochrane Collaboration's tool for assessing risk of bias and the GRADE approach. Four RCTs with a total of 388 patients were included in the meta-analysis. Pooled analysis showed that mesh reinforcement significantly reduced the risk of incisional hernia after AAA repair compared with standard sutured closure (RR 0.27, 95% CI 0.11-0.66). The pooled rate of re-operations was not different between groups (RR 0.23, 95% CI 0.11-1.05). Mesh reinforcement did not cause more intra-operative or post-operative complications than sutured closure. The risk of bias in studies was low and the quality of evidence was rated as moderate. Prophylactic mesh reinforcement of the abdominal wall after open AAA repair via midline laparotomy significantly reduces the risk of incisional hernia. However, no significant difference in re-operation for incisional hernia was found. Copyright © 2018 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.

  4. Paradigm shift regarding the transversalis fascia, preperitoneal space, and Retzius' space.

    PubMed

    Asakage, N

    2018-06-01

    There has been confusion in the anatomical recognition when performing inguinal hernia operations in Japan. From now on, a paradigm shift from the concept of two-dimensional layer structure to the three-dimensional space recognition is necessary to promote an understanding of anatomy. Along with the formation of the abdominal wall, the extraperitoneal space is formed by the transversalis fascia and preperitoneal space. The transversalis fascia is a somatic vascular fascia originating from an arteriovenous fascia. It is a dense areolar tissue layer at the outermost of the extraperitoneal space that runs under the diaphragm and widely lines the body wall muscle. The umbilical funiculus is taken into the abdominal wall and transformed into the preperitoneal space that is a local three-dimensional cavity enveloping preperitoneal fasciae composed of the renal fascia, vesicohypogastric fascia, and testiculoeferential fascia. The Retzius' space is an artificial cavity formed at the boundary between the transversalis fascia and preperitoneal space. In the underlay mesh repair, the mesh expands in the range spanning across the Retzius' space and preperitoneal space.

  5. A mixed volume grid approach for the Euler and Navier-Stokes equations

    NASA Technical Reports Server (NTRS)

    Coirier, William J.; Jorgenson, Philip C. E.

    1996-01-01

    An approach for solving the compressible Euler and Navier-Stokes equations upon meshes composed of nearly arbitrary polyhedra is described. Each polyhedron is constructed from an arbitrary number of triangular and quadrilateral face elements, allowing the unified treatment of tetrahedral, prismatic, pyramidal, and hexahedral cells, as well the general cut cells produced by Cartesian mesh approaches. The basics behind the numerical approach and the resulting data structures are described. The accuracy of the mixed volume grid approach is assessed by performing a grid refinement study upon a series of hexahedral, tetrahedral, prismatic, and Cartesian meshes for an analytic inviscid problem. A series of laminar validation cases are made, comparing the results upon differing grid topologies to each other, to theory, and experimental data. A computation upon a prismatic/tetrahedral mesh is made simulating the laminar flow over a wall/cylinder combination.

  6. A Hybrid Numerical Analysis Method for Structural Health Monitoring

    NASA Technical Reports Server (NTRS)

    Forth, Scott C.; Staroselsky, Alexander

    2001-01-01

    A new hybrid surface-integral-finite-element numerical scheme has been developed to model a three-dimensional crack propagating through a thin, multi-layered coating. The finite element method was used to model the physical state of the coating (far field), and the surface integral method was used to model the fatigue crack growth. The two formulations are coupled through the need to satisfy boundary conditions on the crack surface and the external boundary. The coupling is sufficiently weak that the surface integral mesh of the crack surface and the finite element mesh of the uncracked volume can be set up independently. Thus when modeling crack growth, the finite element mesh can remain fixed for the duration of the simulation as the crack mesh is advanced. This method was implemented to evaluate the feasibility of fabricating a structural health monitoring system for real-time detection of surface cracks propagating in engine components. In this work, the authors formulate the hybrid surface-integral-finite-element method and discuss the mechanical issues of implementing a structural health monitoring system in an aircraft engine environment.

  7. Comparison of the fracture resistances of glass fiber mesh- and metal mesh-reinforced maxillary complete denture under dynamic fatigue loading.

    PubMed

    Im, So-Min; Huh, Yoon-Hyuk; Cho, Lee-Ra; Park, Chan-Jin

    2017-02-01

    The aim of this study was to investigate the effect of reinforcing materials on the fracture resistances of glass fiber mesh- and Cr-Co metal mesh-reinforced maxillary complete dentures under fatigue loading. Glass fiber mesh- and Cr-Co mesh-reinforced maxillary complete dentures were fabricated using silicone molds and acrylic resin. A control group was prepared with no reinforcement (n = 15 per group). After fatigue loading was applied using a chewing simulator, fracture resistance was measured by a universal testing machine. The fracture patterns were analyzed and the fractured surfaces were observed by scanning electron microscopy. After cyclic loading, none of the dentures showed cracks or fractures. During fracture resistance testing, all unreinforced dentures experienced complete fracture. The mesh-reinforced dentures primarily showed posterior framework fracture. Deformation of the all-metal framework caused the metal mesh-reinforced denture to exhibit the highest fracture resistance, followed by the glass fiber mesh-reinforced denture ( P <.05) and the control group ( P <.05). The glass fiber mesh-reinforced denture primarily maintained its original shape with unbroken fibers. River line pattern of the control group, dimples and interdendritic fractures of the metal mesh group, and radial fracture lines of the glass fiber group were observed on the fractured surfaces. The glass fiber mesh-reinforced denture exhibits a fracture resistance higher than that of the unreinforced denture, but lower than that of the metal mesh-reinforced denture because of the deformation of the metal mesh. The glass fiber mesh-reinforced denture maintains its shape even after fracture, indicating the possibility of easier repair.

  8. Automatic Thickness and Volume Estimation of Sprayed Concrete on Anchored Retaining Walls from Terrestrial LIDAR Data

    NASA Astrophysics Data System (ADS)

    Martínez-Sánchez, J.; Puente, I.; GonzálezJorge, H.; Riveiro, B.; Arias, P.

    2016-06-01

    When ground conditions are weak, particularly in free formed tunnel linings or retaining walls, sprayed concrete can be applied on the exposed surfaces immediately after excavation for shotcreting rock outcrops. In these situations, shotcrete is normally applied conjointly with rock bolts and mesh, thereby supporting the loose material that causes many of the small ground falls. On the other hand, contractors want to determine the thickness and volume of sprayed concrete for both technical and economic reasons: to guarantee their structural strength but also, to not deliver excess material that they will not be paid for. In this paper, we first introduce a terrestrial LiDAR-based method for the automatic detection of rock bolts, as typically used in anchored retaining walls. These ground support elements are segmented based on their geometry and they will serve as control points for the co-registration of two successive scans, before and after shotcreting. Then we compare both point clouds to estimate the sprayed concrete thickness and the expending volume on the wall. This novel methodology is demonstrated on repeated scan data from a retaining wall in the city of Vigo (Spain), resulting in a rock bolts detection rate of 91%, that permits to obtain a detailed information of the thickness and calculate a total volume of 3597 litres of concrete. These results have verified the effectiveness of the developed approach by increasing productivity and improving previous empirical proposals for real time thickness estimation.

  9. GPU surface extraction using the closest point embedding

    NASA Astrophysics Data System (ADS)

    Kim, Mark; Hansen, Charles

    2015-01-01

    Isosurface extraction is a fundamental technique used for both surface reconstruction and mesh generation. One method to extract well-formed isosurfaces is a particle system; unfortunately, particle systems can be slow. In this paper, we introduce an enhanced parallel particle system that uses the closest point embedding as the surface representation to speedup the particle system for isosurface extraction. The closest point embedding is used in the Closest Point Method (CPM), a technique that uses a standard three dimensional numerical PDE solver on two dimensional embedded surfaces. To fully take advantage of the closest point embedding, it is coupled with a Barnes-Hut tree code on the GPU. This new technique produces well-formed, conformal unstructured triangular and tetrahedral meshes from labeled multi-material volume datasets. Further, this new parallel implementation of the particle system is faster than any known methods for conformal multi-material mesh extraction. The resulting speed-ups gained in this implementation can reduce the time from labeled data to mesh from hours to minutes and benefits users, such as bioengineers, who employ triangular and tetrahedral meshes

  10. Meshed doped silicon photonic crystals for manipulating near-field thermal radiation

    NASA Astrophysics Data System (ADS)

    Elzouka, Mahmoud; Ndao, Sidy

    2018-01-01

    The ability to control and manipulate heat flow is of great interest to thermal management and thermal logic and memory devices. Particularly, near-field thermal radiation presents a unique opportunity to enhance heat transfer while being able to tailor its characteristics (e.g., spectral selectivity). However, achieving nanometric gaps, necessary for near-field, has been and remains a formidable challenge. Here, we demonstrate significant enhancement of the near-field heat transfer through meshed photonic crystals with separation gaps above 0.5 μm. Using a first-principle method, we investigate the meshed photonic structures numerically via finite-difference time-domain technique (FDTD) along with the Langevin approach. Results for doped-silicon meshed structures show significant enhancement in heat transfer; 26 times over the non-meshed corrugated structures. This is especially important for thermal management and thermal rectification applications. The results also support the premise that thermal radiation at micro scale is a bulk (rather than a surface) phenomenon; the increase in heat transfer between two meshed-corrugated surfaces compared to the flat surface (8.2) wasn't proportional to the increase in the surface area due to the corrugations (9). Results were further validated through good agreements between the resonant modes predicted from the dispersion relation (calculated using a finite-element method), and transmission factors (calculated from FDTD).

  11. Economics of abdominal wall reconstruction.

    PubMed

    Bower, Curtis; Roth, J Scott

    2013-10-01

    The economic aspects of abdominal wall reconstruction are frequently overlooked, although understandings of the financial implications are essential in providing cost-efficient health care. Ventral hernia repairs are frequently performed surgical procedures with significant economic ramifications for employers, insurers, providers, and patients because of the volume of procedures, complication rates, the significant rate of recurrence, and escalating costs. Because biological mesh materials add significant expense to the costs of treating complex abdominal wall hernias, the role of such costly materials needs to be better defined to ensure the most cost-efficient and effective treatments for ventral abdominal wall hernias. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Automatic detection of sweep-meshable volumes

    DOEpatents

    Tautges,; Timothy J. , White; David, R [Pittsburgh, PA

    2006-05-23

    A method of and software for automatically determining whether a mesh can be generated by sweeping for a representation of a geometric solid comprising: classifying surface mesh schemes for surfaces of the representation locally using surface vertex types; grouping mappable and submappable surfaces of the representation into chains; computing volume edge types for the representation; recursively traversing surfaces of the representation and grouping the surfaces into source, target, and linking surface lists; and checking traversal direction when traversing onto linking surfaces.

  13. Influence of four tree shelter types on microclimate and seedling performance of Oregon white oak and western redcedar.

    Treesearch

    Warren D. Devine; Constance A. Harrington

    2008-01-01

    Four types of tree shelters were evaluated in southwestern Washington for their effects on seedling microenvironment and performance of two tree species. Shelter types were fine-mesh fabric shelters, solid-walled white shelters with and without vent holes, and solid-walled blue unvented shelters. Summer mean and daily maximum air temperatures were increased by 0.8 °C...

  14. Escherichia coli peptidoglycan structure and mechanics as predicted by atomic-scale simulations.

    PubMed

    Gumbart, James C; Beeby, Morgan; Jensen, Grant J; Roux, Benoît

    2014-02-01

    Bacteria face the challenging requirement to maintain their shape and avoid rupture due to the high internal turgor pressure, but simultaneously permit the import and export of nutrients, chemical signals, and virulence factors. The bacterial cell wall, a mesh-like structure composed of cross-linked strands of peptidoglycan, fulfills both needs by being semi-rigid, yet sufficiently porous to allow diffusion through it. How the mechanical properties of the cell wall are determined by the molecular features and the spatial arrangement of the relatively thin strands in the larger cellular-scale structure is not known. To examine this issue, we have developed and simulated atomic-scale models of Escherichia coli cell walls in a disordered circumferential arrangement. The cell-wall models are found to possess an anisotropic elasticity, as known experimentally, arising from the orthogonal orientation of the glycan strands and of the peptide cross-links. Other features such as thickness, pore size, and disorder are also found to generally agree with experiments, further supporting the disordered circumferential model of peptidoglycan. The validated constructs illustrate how mesoscopic structure and behavior emerge naturally from the underlying atomic-scale properties and, furthermore, demonstrate the ability of all-atom simulations to reproduce a range of macroscopic observables for extended polymer meshes.

  15. Laser-structured Janus wire mesh for efficient oil-water separation.

    PubMed

    Liu, Yu-Qing; Han, Dong-Dong; Jiao, Zhi-Zhen; Liu, Yan; Jiang, Hao-Bo; Wu, Xuan-Hang; Ding, Hong; Zhang, Yong-Lai; Sun, Hong-Bo

    2017-11-23

    We report here the fabrication of a Janus wire mesh by a combined process of laser structuring and fluorosilane/graphene oxide (GO) modification of the two sides of the mesh, respectively, toward its applications in efficient oil/water separation. Femtosecond laser processing has been employed to make different laser-induced periodic surface structures (LIPSS) on each side of the mesh. Surface modification with fluorosilane on one side and GO on the other side endows the two sides of the Janus mesh with distinct wettability. Thus, one side is superhydrophobic and superoleophilic in air, and the other side is superhydrophilic in air and superoleophobic under water. As a proof of concept, we demonstrated the separation of light/heavy oil and water mixtures using this Janus mesh. To realize an efficient separation, the intrusion pressure that is dominated by the wire mesh framework and the wettability should be taken into account. Our strategy may open up a new way to design and fabricate Janus structures with distinct wettability; and the resultant Janus mesh may find broad applications in the separation of oil contaminants from water.

  16. Organ culture in 3-dimensional matrix: in vitro model for evaluating biological compliance of synthetic meshes for abdominal wall repair.

    PubMed

    Dasdia, T; Bazzaco, S; Bottero, L; Buffa, R; Ferrero, S; Campanelli, G; Dolfini, E

    1998-01-01

    A new in vitro method to evaluate the early critical interactions between synthetic prosthetic materials and growing tissues is reported. The correct spatial organization and proper cell to cell interaction required to mimic the in vivo environment was obtained in a 3-dimensional (3-D) embryo organ culture. The clot formed by plasma and chick-embryo extract provided a natural 3-D extracellular matrix that was able to support the growth and differentiation of intestinal tissue dissected from 12-day-old chick embryos. Different materials used for the repair of abdominal wall defects were taken as standards; all the prosthetic materials were devoid of any evident cytotoxic potential over a 10-day culture period, so they did not interfere with the organogenesis process. A polyglactin mesh (Vicryl) was fully incorporated into the growing tissue, but early signs of its degradation were detectable. The biologically inert materials polyethylene terephthalate (Mersilene) and polypropylene (Marlex, Prolene, and Herniamesh) retained their structural integrity when incubated with cultured tissue at 37 degrees C, and they did not hinder cellular proliferation or fibroblast migration. However, the outgrowth behavior was very different while the connective tissue invaded the interstices of the polyethylene terephthalate mesh; the explants and the migrating cells were repelled by hydrophobic polypropylene meshes. These findings are in agreement with other reported results in in vivo studies. Therefore, this method can be considered as reliable and predictable for the evaluation of biopolymers.

  17. An Experimental and Numerical Study of Diesel Spray Impingement on a Flat Plate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Le; Torelli, Roberto; Zhu, Xiucheng

    Combustion systems with advanced injection strategies have been extensively studied, but there still exists a significant fundamental knowledge gap on fuel spray interactions with the piston surface and chamber walls. This paper is meant to provide detailed data on spray-wall impingement physics and support the spray-wall model development. The experimental work of spray-wall impingement with non-vaporizing spray characterization, was carried out in a high pressure-temperature constant-volume combustion vessel. The simultaneous Mie scattering of liquid spray and schlieren of liquid and vapor spray were carried out. Diesel fuel was injected at a pressure of 1500 bar into ambient gas at amore » density of 22.8 kg/m3 with isothermal conditions (fuel, ambient, and plate temperatures of 423 K). A Lagrangian-Eulerian modeling approach was employed to characterize the spray-gas and spray-wall interactions in the CONVERGE framework by means of a Reynolds-Averaged Navier-Stokes (RANS) formulation. A set of turbulence and spray break-up model constants was identified to properly match the aforementioned measurements of liquid penetration within their experimental confidence intervals. An accuracy study on varying the minimum mesh size was also performed to ensure the grid convergence of the numerical results. Experimentally validated computational fluid dynamics (CFD) simulations were then used to investigate the local spray characteristics in the vicinity of the wall with a particular focus on Sauter Mean Diameter (SMD) and Reynolds and Weber numbers. The analysis was performed by considering before- and after-impingement conditions in order to take in account the influence of the impinged wall on the spray morphology.« less

  18. Evaluation of the Antimicrobial Activity of Lysostaphin-Coated Hernia Repair Meshes▿

    PubMed Central

    Satishkumar, Rohan; Sankar, Sriram; Yurko, Yuliya; Lincourt, Amy; Shipp, John; Heniford, B. Todd; Vertegel, Alexey

    2011-01-01

    Bacterial infections by antibiotic-resistant Staphylococcus aureus strains are among the most common postoperative complications in surgical hernia repair with synthetic mesh. Surface coating of medical devices/implants using antibacterial peptides and enzymes has recently emerged as a potentially effective method for preventing infections. The objective of this study was to evaluate the in vitro antimicrobial activity of hernia repair meshes coated by the antimicrobial enzyme lysostaphin at different initial concentrations. Lysostaphin was adsorbed on pieces of polypropylene (Ultrapro) mesh with binding yields of ∼10 to 40% at different coating concentrations of between 10 and 500 μg/ml. Leaching of enzyme from the surface of all the samples was studied in 2% (wt/vol) bovine serum albumin in phosphate-buffered saline buffer at 37°C, and it was found that less than 3% of adsorbed enzyme desorbed from the surface after 24 h of incubation. Studies of antibacterial activity against a cell suspension of S. aureus were performed using turbidity assay and demonstrated that the small amount of enzyme leaching from the mesh surface contributes to the lytic activity of the lysostaphin-coated samples. Colony counting data from the broth count (model for bacteria in wound fluid) and wash count (model for colonized bacteria) for the enzyme-coated samples showed significantly decreased numbers of CFU compared to uncoated samples (P < 0.05). A pilot in vivo study showed a dose-dependent efficacy of lysostaphin-coated meshes in a rat model of S. aureus infection. The antimicrobial activity of the lysostaphin-coated meshes suggests that such enzyme-leaching surfaces could be efficient at actively resisting initial bacterial adhesion and preventing subsequent colonization of hernia repair meshes. PMID:21709102

  19. Merging Surface Reconstructions of Terrestrial and Airborne LIDAR Range Data

    DTIC Science & Technology

    2009-05-19

    Mangan and R. Whitaker. Partitioning 3D surface meshes using watershed segmentation . IEEE Trans. on Visualization and Computer Graphics, 5(4), pp...Jain, and A. Zakhor. Data Processing Algorithms for Generating Textured 3D Building Facade Meshes from Laser Scans and Camera Images. International...acquired set of overlapping range images into a single mesh [2,9,10]. However, due to the volume of data involved in large scale urban modeling, data

  20. Altering surface characteristics of polypropylene mesh via sodium hydroxide treatment.

    PubMed

    Regis, Shawn; Jassal, Manisha; Mukherjee, Nilay; Bayon, Yves; Scarborough, Nelson; Bhowmick, Sankha

    2012-05-01

    Incisional hernias represent a serious and common complication following laparotomy. The use of synthetic (e.g. polypropylene) meshes to aid repair of these hernias has considerably reduced recurrence rates. While polypropylene is biocompatible and has a long successful clinical history in treating hernias and preventing reherniation, this material may suffer some limitations, particularly in challenging patients at risk of wound failure due to, for example, an exaggerated inflammation reaction, delayed wound healing, and infection. Surface modification of the polypropylene mesh without sacrificing its mechanical properties, critical for hernia repair, represents one way to begin to address these clinical complications. Our hypothesis is treatment of a proprietary polypropylene mesh with sodium hydroxide (NaOH) will increase in vitro NIH/3T3 cell attachment, predictive of earlier and improved cell colonization and tissue integration of polypropylene materials. Our goal is to achieve this altered surface functionality via enhanced removal of chemicals/oils used during material synthesis without compromising the mechanical properties of the mesh. We found that NaOH treatment does not appear to compromise the mechanical strength of the material, despite roughly a 10% decrease in fiber diameter. The treatment increases in vitro NIH/3T3 cell attachment within the first 72 h and this effect is sustained up to 7 days in vitro. This research demonstrates that sodium hydroxide treatment is an efficient way to modify the surface of polypropylene hernia meshes without losing the mechanical integrity of the material. This simple procedure could also allow the attachment of a variety of biomolecules to the polypropylene mesh that may aid in reducing the complications associated with polypropylene meshes today. Copyright © 2012 Wiley Periodicals, Inc.

  1. Bioinspired nanoparticle spray-coating for superhydrophobic flexible materials with oil/water separation capabilities.

    PubMed

    Geraldi, Nicasio R; Dodd, Linzi E; Xu, Ben B; Wood, David; Wells, Gary G; McHale, Glen; Newton, Michael I

    2018-02-02

    Much of the inspiration for the creation of superhydrophobic surfaces has come from nature, from plants such as the sacred lotus (Nelumbo nucifera), where the micro-scale papillae epidermal cells on the surfaces of the leaves are covered with nano-scale epicuticular wax crystalloids. The combination of the surface roughness and the hydrophobic wax coating produces a superhydrophobic wetting state on the leaves, allowing them to self-clean and easily shed water. Here, a simple scaled-up carbon nanoparticle spray coating is presented that mimics the surface of sacred lotus leaves and can be applied to a wide variety of materials, complex structures, and flexible substrates, rendering them superhydrophobic, with contact angles above 160°. The sprayable mixture is produced by combining toluene, polydimethylsiloxane, and inherently hydrophobic rapeseed soot. The ability to spray the superhydrophobic coating allows for the hydrophobisation of complex structures such as metallic meshes, which allows for the production of flexible porous superhydrophobic materials that, when formed into U-shaped channels, can be used to direct flows. The porous meshes, whilst being superhydrophobic, are also oleophilic. Being both superhydrophobic and oleophilic allows oil to pass through the mesh, whilst water remains on the surface. The meshes were tested for their ability to separate mixtures of oil and water in flow conditions. When silicone oil/water mixtures were passed over the meshes, all meshes tested were capable of separating more than 93% of the oil from the mixture.

  2. Inguinal hernia repair

    MedlinePlus

    ... through this weakened area. Description During surgery to repair the hernia, the bulging tissue is pushed back in. Your abdominal wall is strengthened and supported with sutures (stitches), and sometimes mesh. This repair can be done with open or laparoscopic surgery. ...

  3. Three-dimensional atrial wall thickness maps to inform catheter ablation procedures for atrial fibrillation.

    PubMed

    Bishop, Martin; Rajani, Ronak; Plank, Gernot; Gaddum, Nicholas; Carr-White, Gerry; Wright, Matt; O'Neill, Mark; Niederer, Steven

    2016-03-01

    Transmural lesion formation is critical to success in atrial fibrillation ablation and is dependent on left atrial wall thickness (LAWT). Pre- and peri-procedural planning may benefit from LAWT measurements. To calculate the LAWT, the Laplace equation was solved over a finite element mesh of the left atrium derived from the segmented computed tomographic angiography (CTA) dataset. Local LAWT was then calculated from the length of field lines derived from the Laplace solution that spanned the wall from the endocardium or epicardium. The method was validated on an atrium phantom and retrospectively applied to 10 patients who underwent routine coronary CTA for standard clinical indications at our institute. The Laplace wall thickness algorithm was validated on the left atrium phantom. Wall thickness measurements had errors of <0.2 mm for thicknesses of 0.5-5.0 mm that are attributed to image resolution and segmentation artefacts. Left atrial wall thickness measurements were performed on 10 patients. Successful comprehensive LAWT maps were generated in all patients from the coronary CTA images. Mean LAWT measurements ranged from 0.6 to 1.0 mm and showed significant inter and intra patient variability. Left atrial wall thickness can be measured robustly and efficiently across the whole left atrium using a solution of the Laplace equation over a finite element mesh of the left atrium. Further studies are indicated to determine whether the integration of LAWT maps into pre-existing 3D anatomical mapping systems may provide important anatomical information for guiding radiofrequency ablation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  4. A Twelve-Year Consecutive Case Experience in Thoracic Reconstruction

    PubMed Central

    Chen, Jenny T.; Bonneau, Laura A.; Weigel, Tracey L.; Maloney, James D.; Castro, Francisco; Shulzhenko, Nikita

    2016-01-01

    Background: We describe the second largest contemporary series of flaps used in thoracic reconstruction. Methods: A retrospective review of patients undergoing thoracomyoplasty from 2001 to 2013 was conducted. Ninety-one consecutive patients were identified. Results: Thoracomyoplasty was performed for 67 patients with intrathoracic indications and 24 patients with chest wall defects. Malignancy and infection were the most common indications for reconstruction (P < 0.01). The latissimus dorsi (LD), pectoralis major, and serratus anterior muscle flaps remained the workhorses of reconstruction (LD and pectoralis major: 64% flaps in chest wall reconstruction; LD and serratus anterior: 85% of flaps in intrathoracic indication). Only 12% of patients required mesh. Only 6% of patients with <2 ribs resected required mesh when compared with 24% with 3–4 ribs, and 100% with 5 or more ribs resected (P < 0.01). Increased rib resections required in chest wall reconstruction resulted in a longer hospital stay (P < 0.01). Total comorbidities and complications were related to length of stay only in intrathoracic indication (P < 0.01). Average intubation time was significantly higher in patients undergoing intrathoracic indication (5.51 days) than chest wall reconstruction (0.04 days), P < 0.05. Average hospital stay was significantly higher in patients undergoing intrathoracic indication (23 days) than chest wall reconstruction (12 days), P < 0.05. One-year survival was most poor for intrathoracic indication (59%) versus chest wall reconstruction (83%), P = 0.0048. Conclusion: Thoracic reconstruction remains a safe and successful intervention that reliably treats complex and challenging problems, allowing more complex thoracic surgery problems to be salvaged. PMID:27257568

  5. Comparison of the fracture resistances of glass fiber mesh- and metal mesh-reinforced maxillary complete denture under dynamic fatigue loading

    PubMed Central

    2017-01-01

    PURPOSE The aim of this study was to investigate the effect of reinforcing materials on the fracture resistances of glass fiber mesh- and Cr–Co metal mesh-reinforced maxillary complete dentures under fatigue loading. MATERIALS AND METHODS Glass fiber mesh- and Cr–Co mesh-reinforced maxillary complete dentures were fabricated using silicone molds and acrylic resin. A control group was prepared with no reinforcement (n = 15 per group). After fatigue loading was applied using a chewing simulator, fracture resistance was measured by a universal testing machine. The fracture patterns were analyzed and the fractured surfaces were observed by scanning electron microscopy. RESULTS After cyclic loading, none of the dentures showed cracks or fractures. During fracture resistance testing, all unreinforced dentures experienced complete fracture. The mesh-reinforced dentures primarily showed posterior framework fracture. Deformation of the all-metal framework caused the metal mesh-reinforced denture to exhibit the highest fracture resistance, followed by the glass fiber mesh-reinforced denture (P<.05) and the control group (P<.05). The glass fiber mesh-reinforced denture primarily maintained its original shape with unbroken fibers. River line pattern of the control group, dimples and interdendritic fractures of the metal mesh group, and radial fracture lines of the glass fiber group were observed on the fractured surfaces. CONCLUSION The glass fiber mesh-reinforced denture exhibits a fracture resistance higher than that of the unreinforced denture, but lower than that of the metal mesh-reinforced denture because of the deformation of the metal mesh. The glass fiber mesh-reinforced denture maintains its shape even after fracture, indicating the possibility of easier repair. PMID:28243388

  6. Numerical Analysis of Coolant Flow and Heat Transfer in ITER Diagnostic First Wall

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khodak, A.; Loesser, G.; Zhai, Y.

    2015-07-24

    We performed numerical simulations of the ITER Diagnostic First Wall (DFW) using ANSYS workbench. During operation DFW will include solid main body as well as liquid coolant. Thus thermal and hydraulic analysis of the DFW was performed using conjugated heat transfer approach, in which heat transfer was resolved in both solid and liquid parts, and simultaneously fluid dynamics analysis was performed only in the liquid part. This approach includes interface between solid and liquid part of the systemAnalysis was performed using ANSYS CFX software. CFX software allows solution of heat transfer equations in solid and liquid part, and solution ofmore » the flow equations in the liquid part. Coolant flow in the DFW was assumed turbulent and was resolved using Reynolds averaged Navier-Stokes equations with Shear Stress Transport turbulence model. Meshing was performed using CFX method available within ANSYS. The data cloud for thermal loading consisting of volumetric heating and surface heating was imported into CFX Volumetric heating source was generated using Attila software. Surface heating was obtained using radiation heat transfer analysis. Our results allowed us to identify areas of excessive heating. Proposals for cooling channel relocation were made. Additional suggestions were made to improve hydraulic performance of the cooling system.« less

  7. A multi-scale model for geared transmission aero-thermodynamics

    NASA Astrophysics Data System (ADS)

    McIntyre, Sean M.

    A multi-scale, multi-physics computational tool for the simulation of high-per- formance gearbox aero-thermodynamics was developed and applied to equilibrium and pathological loss-of-lubrication performance simulation. The physical processes at play in these systems include multiphase compressible ow of the air and lubricant within the gearbox, meshing kinematics and tribology, as well as heat transfer by conduction, and free and forced convection. These physics are coupled across their representative space and time scales in the computational framework developed in this dissertation. These scales span eight orders of magnitude, from the thermal response of the full gearbox O(100 m; 10 2 s), through effects at the tooth passage time scale O(10-2 m; 10-4 s), down to tribological effects on the meshing gear teeth O(10-6 m; 10-6 s). Direct numerical simulation of these coupled physics and scales is intractable. Accordingly, a scale-segregated simulation strategy was developed by partitioning and treating the contributing physical mechanisms as sub-problems, each with associated space and time scales, and appropriate coupling mechanisms. These are: (1) the long time scale thermal response of the system, (2) the multiphase (air, droplets, and film) aerodynamic flow and convective heat transfer within the gearbox, (3) the high-frequency, time-periodic thermal effects of gear tooth heating while in mesh and its subsequent cooling through the rest of rotation, (4) meshing effects including tribology and contact mechanics. The overarching goal of this dissertation was to develop software and analysis procedures for gearbox loss-of-lubrication performance. To accommodate these four physical effects and their coupling, each is treated in the CFD code as a sub problem. These physics modules are coupled algorithmically. Specifically, the high- frequency conduction analysis derives its local heat transfer coefficient and near-wall air temperature boundary conditions from a quasi-steady cyclic-symmetric simulation of the internal flow. This high-frequency conduction solution is coupled directly with a model for the meshing friction, developed by a collaborator, which was adapted for use in a finite-volume CFD code. The local surface heat flux on solid surfaces is calculated by time-averaging the heat flux in the high-frequency analysis. This serves as a fixed-flux boundary condition in the long time scale conduction module. The temperature distribution from this long time scale heat transfer calculation serves as a boundary condition for the internal convection simulation, and as the initial condition for the high-frequency heat transfer module. Using this multi-scale model, simulations were performed for equilibrium and loss-of-lubrication operation of the NASA Glenn Research Center test stand. Results were compared with experimental measurements. In addition to the multi-scale model itself, several other specific contributions were made. Eulerian models for droplets and wall-films were developed and im- plemented in the CFD code. A novel approach to retaining liquid film on the solid surfaces, and strategies for its mass exchange with droplets, were developed and verified. Models for interfacial transfer between droplets and wall-film were implemented, and include the effects of droplet deposition, splashing, bouncing, as well as film breakup. These models were validated against airfoil data. To mitigate the observed slow convergence of CFD simulations of the enclosed aerodynamic flows within gearboxes, Fourier stability analysis was applied to the SIMPLE-C fractional-step algorithm. From this, recommendations to accelerate the convergence rate through enhanced pressure-velocity coupling were made. These were shown to be effective. A fast-running finite-volume reduced-order-model of the gearbox aero-thermo- dynamics was developed, and coupled with the tribology model to investigate the sensitivity of loss-of-lubrication predictions to various model and physical param- eters. This sensitivity study was instrumental in guiding efforts toward improving the accuracy of the multi-scale model without undue increase in computational cost. In addition, the reduced-order model is now used extensively by a collaborator in tribology model development and testing. Experimental measurements of high-speed gear windage in partially and fully- shrouded configurations were performed to supplement the paucity of available validation data. This measurement program provided measurements of windage loss for a gear of design-relevant size and operating speed, as well as guidance for increasing the accuracy of future measurements.

  8. Nanowire mesh solar fuels generator

    DOEpatents

    Yang, Peidong; Chan, Candace; Sun, Jianwei; Liu, Bin

    2016-05-24

    This disclosure provides systems, methods, and apparatus related to a nanowire mesh solar fuels generator. In one aspect, a nanowire mesh solar fuels generator includes (1) a photoanode configured to perform water oxidation and (2) a photocathode configured to perform water reduction. The photocathode is in electrical contact with the photoanode. The photoanode may include a high surface area network of photoanode nanowires. The photocathode may include a high surface area network of photocathode nanowires. In some embodiments, the nanowire mesh solar fuels generator may include an ion conductive polymer infiltrating the photoanode and the photocathode in the region where the photocathode is in electrical contact with the photoanode.

  9. Mesh quality oriented 3D geometric vascular modeling based on parallel transport frame.

    PubMed

    Guo, Jixiang; Li, Shun; Chui, Yim Pan; Qin, Jing; Heng, Pheng Ann

    2013-08-01

    While a number of methods have been proposed to reconstruct geometrically and topologically accurate 3D vascular models from medical images, little attention has been paid to constantly maintain high mesh quality of these models during the reconstruction procedure, which is essential for many subsequent applications such as simulation-based surgical training and planning. We propose a set of methods to bridge this gap based on parallel transport frame. An improved bifurcation modeling method and two novel trifurcation modeling methods are developed based on 3D Bézier curve segments in order to ensure the continuous surface transition at furcations. In addition, a frame blending scheme is implemented to solve the twisting problem caused by frame mismatch of two successive furcations. A curvature based adaptive sampling scheme combined with a mesh quality guided frame tilting algorithm is developed to construct an evenly distributed, non-concave and self-intersection free surface mesh for vessels with distinct radius and high curvature. Extensive experiments demonstrate that our methodology can generate vascular models with better mesh quality than previous methods in terms of surface mesh quality criteria. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Numerical investigations of the unsteady blood flow in the end-to-side arteriovenous fistula for hemodialysis.

    PubMed

    Jodko, Daniel; Obidowski, Damian; Reorowicz, Piotr; Jóźwik, Krzysztof

    2016-01-01

    The aim of this study was to investigate the blood flow in the end-to-side arteriovenous (a-v) fistula, taking into account its pulsating nature and the patient-specific geometry of blood vessels. Computational Fluid Dynamics (CFD) methods were used for this analysis. DICOM images of the fistula, obtained from the angio-computed tomography, were a source of the data applied to develop a 3D geometrical model of the fistula. The model was meshed, then the ANSYS CFX v. 15.0 code was used to perform simulations of the flow in the vessels under analysis. Mesh independence tests were conducted. The non-Newtonian rheological model of blood and the Shear Stress Transport model of turbulence were employed. Blood vessel walls were assumed to be rigid. Flow patterns, velocity fields, the volume flow rate, the wall shear stress (WSS) propagation on particular blood vessel walls were shown versus time. The maximal value of the blood velocity was identified in the anastomosis - the place where the artery is connected to the vein. The flow rate was calculated for all veins receiving blood. The blood flow in the geometrically complicated a-v fistula was simulated. The values and oscillations of the WSS are the largest in the anastomosis, much lower in the artery and the lowest in the cephalic vein. A strong influence of the mesh on the results concerning the maximal and area-averaged WSS was shown. The relation between simulations of the pulsating and stationary flow under time-averaged flow conditions was presented.

  11. Conservative DEC Discretization of Incompressible Navier-Stokes Equations on Arbitrary Surface Simplicial Meshes

    NASA Astrophysics Data System (ADS)

    Mohamed, Mamdouh; Hirani, Anil; Samtaney, Ravi

    2017-11-01

    A conservative discretization of incompressible Navier-Stokes equations over surfaces is developed using discrete exterior calculus (DEC). The mimetic character of many of the DEC operators provides exact conservation of both mass and vorticity, in addition to superior kinetic energy conservation. The employment of signed diagonal Hodge star operators, while using the circumcentric dual defined on arbitrary meshes, is shown to produce correct solutions even when many non-Delaunay triangles pairs exist. This allows the DEC discretization to admit arbitrary surface simplicial meshes, in contrast to the previously held notion that DEC was limited only to Delaunay meshes. The discretization scheme is presented along with several numerical test cases demonstrating its numerical convergence and conservation properties. Recent developments regarding the extension to conservative higher order methods are also presented. KAUST Baseline Research Funds of R. Samtaney.

  12. Effects of Titanium Mesh Surfaces-Coated with Hydroxyapatite/β-Tricalcium Phosphate Nanotubes on Acetabular Bone Defects in Rabbits

    PubMed Central

    Nguyen, Thuy-Duong Thi; Bae, Tae-Sung; Yang, Dae-hyeok; Park, Myung-sik; Yoon, Sun-jung

    2017-01-01

    The management of severe acetabular bone defects in revision reconstructive orthopedic surgery is challenging. In this study, cyclic precalcification (CP) treatment was used on both nanotube-surface Ti-mesh and a bone graft substitute for the acetabular defect model, and its effects were assessed in vitro and in vivo. Nanotube-Ti mesh coated with hydroxyapatite/β-tricalcium phosphate (HA/β-TCP) was manufactured by an anodizing and a sintering method, respectively. An 8 mm diameter defect was created on each acetabulum of eight rabbits, then treated by grafting materials and covered by Ti meshes. At four and eight weeks, postoperatively, biopsies were performed for histomorphometric analyses. The newly-formed bone layers under cyclic precalcified anodized Ti (CP-AT) meshes were superior with regard to the mineralized area at both four and eight weeks, as compared with that under untreated Ti meshes. Active bone regeneration at 2–4 weeks was stronger than at 6–8 weeks, particularly with treated biphasic ceramic (p < 0.05). CP improved the bioactivity of Ti meshes and biphasic grafting materials. Moreover, the precalcified nanotubular Ti meshes could enhance early contact bone formation on the mesh and, therefore, may reduce the collapse of Ti meshes into the defect, increasing the sufficiency of acetabular reconstruction. Finally, cyclic precalcification did not affect bone regeneration by biphasic grafting materials in vivo. PMID:28686210

  13. Generating a Simulated Fluid Flow over a Surface Using Anisotropic Diffusion

    NASA Technical Reports Server (NTRS)

    Rodriguez, David L. (Inventor); Sturdza, Peter (Inventor)

    2016-01-01

    A fluid-flow simulation over a computer-generated surface is generated using a diffusion technique. The surface is comprised of a surface mesh of polygons. A boundary-layer fluid property is obtained for a subset of the polygons of the surface mesh. A gradient vector is determined for a selected polygon, the selected polygon belonging to the surface mesh but not one of the subset of polygons. A maximum and minimum diffusion rate is determined along directions determined using the gradient vector corresponding to the selected polygon. A diffusion-path vector is defined between a point in the selected polygon and a neighboring point in a neighboring polygon. An updated fluid property is determined for the selected polygon using a variable diffusion rate, the variable diffusion rate based on the minimum diffusion rate, maximum diffusion rate, and the gradient vector.

  14. Covalent layer-by-layer grafting (LBLG) functionalized superhydrophobic stainless steel mesh for oil/water separation

    NASA Astrophysics Data System (ADS)

    Jiang, Bin; Zhang, Hongjie; Sun, Yongli; Zhang, Luhong; Xu, Lidong; Hao, Li; Yang, Huawei

    2017-06-01

    A superhydrophobic and superoleophilic stainless steel (SS) mesh for oil/water separation has been developed by using a novel, facile and inexpensive covalent layer-by-layer grafting (LBLG) method. Hierarchical micro/nanostructure surface was formed through grafting the (3-aminopropyl) triethoxysilane (SCA), polyethylenimine (PEI) and trimesoyl chloride (TMC) onto the mesh in sequence, accompanied with SiO2 nanoparticles subtly and firmly anchored in multilayers. Superhydrophobic characteristic was realized by self-assembly grafting of hydrophobic groups onto the surface. The as-prepared mesh exhibits excellent superhydrophobicity with a water contact angle of 159°. Moreover, with a low sliding angle of 4°, it shows the "lotus effect" for self-cleaning. As for application evaluation, the as-prepared mesh can be used for large-scale separation of oil/water mixtures with a relatively high separation efficiency after 30 times reuse (99.88% for n-octane/water mixture) and a high intrusion pressure (3.58 kPa). More importantly, the mesh exhibited excellent stability in the case of vibration situation, long-term storage as well as saline corrosion conditions, and the compatible pH range was determined to be 1-13. In summary, this work provides a brand new method of modifying SS mesh in a covalent LBLG way, and makes it possible to introduce various functionalized groups onto the surface.

  15. A semi-automatic computer-aided method for surgical template design

    NASA Astrophysics Data System (ADS)

    Chen, Xiaojun; Xu, Lu; Yang, Yue; Egger, Jan

    2016-02-01

    This paper presents a generalized integrated framework of semi-automatic surgical template design. Several algorithms were implemented including the mesh segmentation, offset surface generation, collision detection, ruled surface generation, etc., and a special software named TemDesigner was developed. With a simple user interface, a customized template can be semi- automatically designed according to the preoperative plan. Firstly, mesh segmentation with signed scalar of vertex is utilized to partition the inner surface from the input surface mesh based on the indicated point loop. Then, the offset surface of the inner surface is obtained through contouring the distance field of the inner surface, and segmented to generate the outer surface. Ruled surface is employed to connect inner and outer surfaces. Finally, drilling tubes are generated according to the preoperative plan through collision detection and merging. It has been applied to the template design for various kinds of surgeries, including oral implantology, cervical pedicle screw insertion, iliosacral screw insertion and osteotomy, demonstrating the efficiency, functionality and generality of our method.

  16. A semi-automatic computer-aided method for surgical template design

    PubMed Central

    Chen, Xiaojun; Xu, Lu; Yang, Yue; Egger, Jan

    2016-01-01

    This paper presents a generalized integrated framework of semi-automatic surgical template design. Several algorithms were implemented including the mesh segmentation, offset surface generation, collision detection, ruled surface generation, etc., and a special software named TemDesigner was developed. With a simple user interface, a customized template can be semi- automatically designed according to the preoperative plan. Firstly, mesh segmentation with signed scalar of vertex is utilized to partition the inner surface from the input surface mesh based on the indicated point loop. Then, the offset surface of the inner surface is obtained through contouring the distance field of the inner surface, and segmented to generate the outer surface. Ruled surface is employed to connect inner and outer surfaces. Finally, drilling tubes are generated according to the preoperative plan through collision detection and merging. It has been applied to the template design for various kinds of surgeries, including oral implantology, cervical pedicle screw insertion, iliosacral screw insertion and osteotomy, demonstrating the efficiency, functionality and generality of our method. PMID:26843434

  17. A semi-automatic computer-aided method for surgical template design.

    PubMed

    Chen, Xiaojun; Xu, Lu; Yang, Yue; Egger, Jan

    2016-02-04

    This paper presents a generalized integrated framework of semi-automatic surgical template design. Several algorithms were implemented including the mesh segmentation, offset surface generation, collision detection, ruled surface generation, etc., and a special software named TemDesigner was developed. With a simple user interface, a customized template can be semi- automatically designed according to the preoperative plan. Firstly, mesh segmentation with signed scalar of vertex is utilized to partition the inner surface from the input surface mesh based on the indicated point loop. Then, the offset surface of the inner surface is obtained through contouring the distance field of the inner surface, and segmented to generate the outer surface. Ruled surface is employed to connect inner and outer surfaces. Finally, drilling tubes are generated according to the preoperative plan through collision detection and merging. It has been applied to the template design for various kinds of surgeries, including oral implantology, cervical pedicle screw insertion, iliosacral screw insertion and osteotomy, demonstrating the efficiency, functionality and generality of our method.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brull, S., E-mail: Stephane.Brull@math.u-bordeaux.fr; Charrier, P., E-mail: Pierre.Charrier@math.u-bordeaux.fr; Mieussens, L., E-mail: Luc.Mieussens@math.u-bordeaux.fr

    It is well known that the roughness of the wall has an effect on microscale gas flows. This effect can be shown for large Knudsen numbers by using a numerical solution of the Boltzmann equation. However, when the wall is rough at a nanometric scale, it is necessary to use a very small mesh size which is much too expansive. An alternative approach is to incorporate the roughness effect in the scattering kernel of the boundary condition, such as the Maxwell-like kernel introduced by the authors in a previous paper. Here, we explain how this boundary condition can be implementedmore » in a discrete velocity approximation of the Boltzmann equation. Moreover, the influence of the roughness is shown by computing the structure scattering pattern of mono-energetic beams of the incident gas molecules. The effect of the angle of incidence of these molecules, of their mass, and of the morphology of the wall is investigated and discussed in a simplified two-dimensional configuration. The effect of the azimuthal angle of the incident beams is shown for a three-dimensional configuration. Finally, the case of non-elastic scattering is considered. All these results suggest that our approach is a promising way to incorporate enough physics of gas-surface interaction, at a reasonable computing cost, to improve kinetic simulations of micro- and nano-flows.« less

  19. Brown class III maxillectomy defects reconstruction with prefabricated titanium mesh and soft tissue free flap.

    PubMed

    Dediol, Emil; Uglešić, Vedran; Zubčić, Vedran; Knežević, Predrag

    2013-07-01

    Midface reconstruction is one of the most challenging tasks for the reconstructive surgeon. We present a technique for the reconstruction of the midface after total maxillectomy with preservation of orbital contents. Skeletal reconstruction is achieved with a preoperatively bent titanium sheet mesh on a universal skeletal model. The alveolar ridge, the anterior wall of the maxillary sinus, the zygomatic prominence, the lower orbital rim, and the orbital floor are reconstructed with a titanium mesh. A soft tissue free flap, preferably anterolateral thigh free flap, is harvested as well. A part of the flap is deepithelized and put in front of the mesh to prevent exposure, and the other part is used for palatal reconstruction. Four male and 1 female patients were reconstructed with titanium mesh. Four free flaps were raised: 3 anterolateral thigh and 1 latissimus dorsi. All free flaps survived. All patients received postoperative irradiation with 64 Gy. Median follow-up was 12 months; no major complications occurred. Mesh was exposed in only 1 case, which was managed successfully with resuspension of the heavy latissimus dorsi myocutaneous flap. Midface projection and height, globe position, ocular movements, and vision where satisfactory in all cases. Midface reconstruction with titanium mesh and soft tissue free flap is a reliable and safe method for functional and aesthetic reconstruction after maxillectomy.

  20. Remote discovery of an asymptomatic bowel perforation by a mid-urethral sling.

    PubMed

    Elliott, Jason E; Maslow, Ken D

    2012-02-01

    Bowel perforation is a rare complication of mid-urethral sling procedures and is usually reported shortly after the surgery. We report a remotely discovered asymptomatic bowel injury found at the time of subsequent surgery. The patient with a history of several prior pelvic surgeries underwent an uneventful retropubic mid-urethral sling placement. Five years later, during an abdominal sacrocolpopexy procedure, mesh from the mid-urethral sling was found perforating the wall of the cecum and fixating it to the right pelvic sidewall. Cecal wedge resection was performed to excise the sling mesh. Asymptomatic bowel perforation by mid-urethral sling mesh has not been previously reported. Pelvic and abdominal surgeons should be aware of the possibility of finding this injury in patients with prior sling surgeries.

  1. Accuracy Quantification of the Loci-CHEM Code for Chamber Wall Heat Transfer in a GO2/GH2 Single Element Model Problem

    NASA Technical Reports Server (NTRS)

    West, Jeff; Westra, Doug; Lin, Jeff; Tucker, Kevin

    2006-01-01

    All solutions with Loci-CHEM achieved demonstrated steady state and mesh convergence. Preconditioning had no effect on solution accuracy and typically yields a 3-5times solution speed-up. The SST turbulence model has superior performance, relative to the data in the head end region, for the rise rate and peak heat flux. It was slightly worse than the others in the downstream region where all over-predicted the data by 30-100%.There was systematic mesh refinement in the unstructured volume and structured boundary layer areas produced only minor solution differences. Mesh convergence was achieved. Overall, Loci-CHEM satisfactorily predicts heat flux rise rate and peak heat flux and significantly over predicts the downstream heat flux.

  2. Cesarean section after abdominal mesh repair for pregnancy-related desmoid tumor: a case report

    PubMed Central

    Ooi, Sara; Ngo, Harry

    2017-01-01

    We report the case of a 32-year-old gravida 2 para 1 woman with a background of partially resected desmoid tumor (DT) arising from the previous cesarean section (CS) scar. This case details the management of her DT by surgical resection and mesh repair and second pregnancy following this. Pregnancy-related DTs are a relatively rare entity, and there is a paucity of literature regarding their management during pregnancy. There are only five reported cases of DTs arising from CS scars. To our knowledge, this is the only report to illustrate that subsequent CS is possible after desmoid resection and abdominal mesh repair. It provides evidence that CS can be safely accomplished following abdominal wall reconstructions and further arguments against elective lower segment CS. PMID:28744163

  3. Cesarean section after abdominal mesh repair for pregnancy-related desmoid tumor: a case report.

    PubMed

    Ooi, Sara; Ngo, Harry

    2017-01-01

    We report the case of a 32-year-old gravida 2 para 1 woman with a background of partially resected desmoid tumor (DT) arising from the previous cesarean section (CS) scar. This case details the management of her DT by surgical resection and mesh repair and second pregnancy following this. Pregnancy-related DTs are a relatively rare entity, and there is a paucity of literature regarding their management during pregnancy. There are only five reported cases of DTs arising from CS scars. To our knowledge, this is the only report to illustrate that subsequent CS is possible after desmoid resection and abdominal mesh repair. It provides evidence that CS can be safely accomplished following abdominal wall reconstructions and further arguments against elective lower segment CS.

  4. [Long-term follow-up results after open small umbilical hernia repairs].

    PubMed

    Malý, O; Sotona, O

    2014-04-01

    Adult umbilical hernia is a common surgical condition in the fifth and sixth decade of life. Despite the high frequency of umbilical hernia repairs, disappointingly high recurrence rates after simple suture repairs are reported, amounting to 54%. In addition, it is reported that with the rising frequency of recurrences, the size of the hernial sac and gate gradually increases. Therefore we decided to find out the incidence of recurrences after operative repair of an umbilical hernia at our department. Patient data for this retrospective study focusing on the period between 2006 and 2010 were obtained from the electronic hospital database. Patients with umbilical hernia and the abdominal wall defect up to 3 cm who underwent primary elective procedure were included in the study. Patients with incisional hernias were excluded. All patients were contacted at least 3 years after operation to confirm the accuracy of data. A total of 127 patients were included in this study. In the abovementioned period, no mesh was used during primary surgery in any of the patients. Recurrence occurred in a total of 13.4% of patients. Approximately 40% of patients with the first recurrence were re-operated at our department, 30% of patients were re-operated in other hospitals and the rest have not sought medical attention in respect of the recurrence. Patients with recurrence did not differ from the others as regards age, body mass index or surgical site infection development. Due to the high recurrence rates after operative sutures of the umbilical hernias there is a need to thoroughly consider the potential risk factors such as the body mass index and the abdominal wall defect size. Therefore, it is recommended to use the mesh more widely during primary surgery, especially in obese patients with BMI over 30 and the wall defect size exceeding 3 cm. The question remains whether to use the mesh in all overweight patients and with wall defect smaller than 3 cm.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    OWEN,STEVEN J.

    A method for decomposing a volume with a prescribed quadrilateral surface mesh, into a hexahedral-dominated mesh is proposed. With this method, known as Hex-Morphing (H-Morph), an initial tetrahedral mesh is provided. Tetrahedral are transformed and combined starting from the boundary and working towards the interior of the volume. The quadrilateral faces of the hexahedra are treated as internal surfaces, which can be recovered using constrained triangulation techniques. Implementation details of the edge and face recovery process are included. Examples and performance of the H-Morph algorithm are also presented.

  6. Boundary element based multiresolution shape optimisation in electrostatics

    NASA Astrophysics Data System (ADS)

    Bandara, Kosala; Cirak, Fehmi; Of, Günther; Steinbach, Olaf; Zapletal, Jan

    2015-09-01

    We consider the shape optimisation of high-voltage devices subject to electrostatic field equations by combining fast boundary elements with multiresolution subdivision surfaces. The geometry of the domain is described with subdivision surfaces and different resolutions of the same geometry are used for optimisation and analysis. The primal and adjoint problems are discretised with the boundary element method using a sufficiently fine control mesh. For shape optimisation the geometry is updated starting from the coarsest control mesh with increasingly finer control meshes. The multiresolution approach effectively prevents the appearance of non-physical geometry oscillations in the optimised shapes. Moreover, there is no need for mesh regeneration or smoothing during the optimisation due to the absence of a volume mesh. We present several numerical experiments and one industrial application to demonstrate the robustness and versatility of the developed approach.

  7. Fractal vein distributions within a fault-fracture mesh in an exhumed accretionary mélange, Chrystalls Beach Complex, New Zealand

    NASA Astrophysics Data System (ADS)

    Fagereng, Åke

    2011-05-01

    A well developed fault-fracture mesh is observed in the Chrystalls Beach Complex, an accretionary mélange within the Otago Schist on the South Island of New Zealand. In this study, an analysis of vein thicknesses and clustering of veins is presented. Both shear and extension veins have a power-law thickness distribution. Measures of vein spacing best fit a power-law distribution, but a small data set limits this interpretation to a small fractal range. Vein clustering varies from random to moderately clustered between outcrops, and is the greatest where a large proportion of relatively competent blocks occurs within the mélange. Fractures are distributed within the mélange matrix, and this localized deformation requires heterogeneity in rheology and/or fluid pressure distribution, whereas pervasive, distributed deformation occurs in relatively homogeneous rock. The overall trend of this deformation being mainly accommodated by thin veins required that new fractures formed preferentially over refracturing existing veins, which highlights the distributed nature of deformation within a fault-fracture mesh. The predominance of new fractures may result from vein material being stronger than the cleaved wall rock, such that wall rock failure occurred instead of reopening of pre-existing shear and extension veins.

  8. [Research of the durability of connective tissue complexes formed in the implantation area of various types of allograft during the experiment].

    PubMed

    Ioffe, O Iu; Shvets', I M; Stetsenko, O P; Tsiura, Iu P; Tarasiuk, T V; Lamashevs'kyĭ, V P; Makovets'kyĭ, I V; Furmanov, Iu O

    2014-01-01

    The aim of the study is to examine in the experiment on the animals the mechanical properties of connective tissue complexes formed in alloplasty area using the intraperitoneal on lay mesh and sublay methodologies with further comparison of them. The experiment has been conducted on 12 rabbits of Russian chinchilla breed. Animals were distributed in the following way: the first group--operated by intraperitoneal on lay mesh methodology (n = 6) through implantation of composite grid Proceed with one-side celullose coating produced by "Ethicon" company. The second group--performed modeling of preperitoneal plastic using two-component composite grid with large-pores Ultrapro produced by "Ethicon" company (n = 6). For the tensometric evaluation of the strength of implant integration into the red wall was used entire area of anterior red wall together with the implanted transplant. According to the deflection diagrams and dynamometer rates defined the maximum burden rates which is equivalent of muscular tissue budge against polymeric matrix. Statistically significant distinctions during 14 days were not detected; however strength during 30 days in the first group was 3 times higher than in the second group. We consider that the methodology of intraperitoneal on lay mesh can be considered as operation of choice of surgery treatment of the umbilical hernias.

  9. What Do We Know About Component Separation Techniques for Abdominal Wall Hernia Repair?

    PubMed

    Scheuerlein, Hubert; Thiessen, Andreas; Schug-Pass, Christine; Köckerling, Ferdinand

    2018-01-01

    The component separation technique (CST) was introduced to abdominal wall reconstruction to treat large, complex hernias. It is very difficult to compare the published findings because of the vast number of technical modifications to CST as well as the heterogeneity of the patient population operated on with this technique. The main focus of the literature search conducted up to August 2017 in Medline and PubMed was on publications reporting comparative findings as well as on systematic reviews in order to formulate statements regarding the various CSTs. CST without mesh should no longer be performed because of too high recurrence rates. Open anterior CST has too high a surgical site occurrence rate and henceforth should only be conducted as endoscopic and perforator sparing anterior CST. Open posterior CST and posterior CST with transversus abdominis release (TAR) produce better results than open anterior CST. To date, no significant differences have been found between endoscopic anterior, perforator sparing anterior CST and posterior CST with transversus abdominis release. Robot-assisted posterior CST with TAR is the latest, very promising alternative. The systematic use of biologic meshes cannot be recommended for CST. CST should always be performed with mesh as endoscopic or perforator sparing anterior or posterior CST. Robot-assisted posterior CST with TAR is the latest development.

  10. Simultaneous multiple view high resolution surface geometry acquisition using structured light and mirrors.

    PubMed

    Basevi, Hector R A; Guggenheim, James A; Dehghani, Hamid; Styles, Iain B

    2013-03-25

    Knowledge of the surface geometry of an imaging subject is important in many applications. This information can be obtained via a number of different techniques, including time of flight imaging, photogrammetry, and fringe projection profilometry. Existing systems may have restrictions on instrument geometry, require expensive optics, or require moving parts in order to image the full surface of the subject. An inexpensive generalised fringe projection profilometry system is proposed that can account for arbitrarily placed components and use mirrors to expand the field of view. It simultaneously acquires multiple views of an imaging subject, producing a cloud of points that lie on its surface, which can then be processed to form a three dimensional model. A prototype of this system was integrated into an existing Diffuse Optical Tomography and Bioluminescence Tomography small animal imaging system and used to image objects including a mouse-shaped plastic phantom, a mouse cadaver, and a coin. A surface mesh generated from surface capture data of the mouse-shaped plastic phantom was compared with ideal surface points provided by the phantom manufacturer, and 50% of points were found to lie within 0.1mm of the surface mesh, 82% of points were found to lie within 0.2mm of the surface mesh, and 96% of points were found to lie within 0.4mm of the surface mesh.

  11. Radial cold trap

    DOEpatents

    Grundy, Brian R.

    1981-01-01

    The radial cold trap comprises a housing having a plurality of mesh bands disposed therein. The mesh bands comprise concentrically arranged bands of mesh with the mesh specific surface area of each band increasing from the outermost mesh band to the innermost mesh band. An inlet nozzle is attached to the outside section of the housing while an outlet nozzle is attached to the inner portion of the housing so as to be concentrically connected to the innermost mesh band. An inlet baffle having orifices therein may be disposed around the outermost mesh band and within the housing for directing the flow of the fluid from the inlet nozzle to the outermost mesh band in a uniform manner. The flow of fluid passes through each consecutive mesh band and into the outlet nozzle. The circular pattern of the symmetrically arranged mesh packing allows for better utilization of the entire cold trap volume.

  12. Radial cold trap

    DOEpatents

    Grundy, B.R.

    1981-09-29

    The radial cold trap comprises a housing having a plurality of mesh bands disposed therein. The mesh bands comprise concentrically arranged bands of mesh with the mesh specific surface area of each band increasing from the outermost mesh band to the innermost mesh band. An inlet nozzle is attached to the outside section of the housing while an outlet nozzle is attached to the inner portion of the housing so as to be concentrically connected to the innermost mesh band. An inlet baffle having orifices therein may be disposed around the outermost mesh band and within the housing for directing the flow of the fluid from the inlet nozzle to the outermost mesh band in a uniform manner. The flow of fluid passes through each consecutive mesh band and into the outlet nozzle. The circular pattern of the symmetrically arranged mesh packing allows for better utilization of the entire cold trap volume. 2 figs.

  13. Ubiquitous Low-Cost Functionalized Multi-Walled Carbon Nanotube Sensors for Distributed Methane Leak Detection

    DOE PAGES

    Humayun, Md Tanim; Divan, Ralu; Stan, Liliana; ...

    2016-06-16

    This paper presents a highly sensitive, energy efficient and low-cost distributed methane (CH 4) sensor system (DMSS) for continuous monitoring, detection, and localization of CH 4 leaks in natural gas infrastructure, such as transmission and distribution pipelines, wells, and production pads. The CH 4 sensing element, a key component of the DMSS, consists of a metal oxide nanocrystal (MONC) functionalized multi-walled carbon nanotube (MWCNT) mesh which, in comparison to existing literature, shows stronger relative resistance change while interacting with lower parts per million (ppm) concentration of CH 4. A Gaussian plume triangulation algorithm has been developed for the DMSS. Givenmore » a geometric model of the surrounding environment the algorithm can precisely detect and localize a CH 4 leak as well as estimate its mass emission rate. A UV-based surface recovery technique making the sensor recover 10 times faster than the reported ones is presented for the DMSS. In conclusion, a control algorithm based on the UV-accelerated recovery is developed which facilitates faster leak detection.« less

  14. Fog collecting biomimetic surfaces: Influence of microstructure and wettability.

    PubMed

    Azad, M A K; Ellerbrok, D; Barthlott, W; Koch, K

    2015-01-19

    We analyzed the fog collection efficiency of three different sets of samples: replica (with and without microstructures), copper wire (smooth and microgrooved) and polyolefin mesh (hydrophilic, superhydrophilic and hydrophobic). The collection efficiency of the samples was compared in each set separately to investigate the influence of microstructures and/or the wettability of the surfaces on fog collection. Based on the controlled experimental conditions chosen here large differences in the efficiency were found. We found that microstructured plant replica samples collected 2-3 times higher amounts of water than that of unstructured (smooth) samples. Copper wire samples showed similar results. Moreover, microgrooved wires had a faster dripping of water droplets than that of smooth wires. The superhydrophilic mesh tested here was proved more efficient than any other mesh samples with different wettability. The amount of collected fog by superhydrophilic mesh was about 5 times higher than that of hydrophilic (untreated) mesh and was about 2 times higher than that of hydrophobic mesh.

  15. An Efficient Radial Basis Function Mesh Deformation Scheme within an Adjoint-Based Aerodynamic Optimization Framework

    NASA Astrophysics Data System (ADS)

    Poirier, Vincent

    Mesh deformation schemes play an important role in numerical aerodynamic optimization. As the aerodynamic shape changes, the computational mesh must adapt to conform to the deformed geometry. In this work, an extension to an existing fast and robust Radial Basis Function (RBF) mesh movement scheme is presented. Using a reduced set of surface points to define the mesh deformation increases the efficiency of the RBF method; however, at the cost of introducing errors into the parameterization by not recovering the exact displacement of all surface points. A secondary mesh movement is implemented, within an adjoint-based optimization framework, to eliminate these errors. The proposed scheme is tested within a 3D Euler flow by reducing the pressure drag while maintaining lift of a wing-body configured Boeing-747 and an Onera-M6 wing. As well, an inverse pressure design is executed on the Onera-M6 wing and an inverse span loading case is presented for a wing-body configured DLR-F6 aircraft.

  16. Stochastic Surface Mesh Reconstruction

    NASA Astrophysics Data System (ADS)

    Ozendi, M.; Akca, D.; Topan, H.

    2018-05-01

    A generic and practical methodology is presented for 3D surface mesh reconstruction from the terrestrial laser scanner (TLS) derived point clouds. It has two main steps. The first step deals with developing an anisotropic point error model, which is capable of computing the theoretical precisions of 3D coordinates of each individual point in the point cloud. The magnitude and direction of the errors are represented in the form of error ellipsoids. The following second step is focused on the stochastic surface mesh reconstruction. It exploits the previously determined error ellipsoids by computing a point-wise quality measure, which takes into account the semi-diagonal axis length of the error ellipsoid. The points only with the least errors are used in the surface triangulation. The remaining ones are automatically discarded.

  17. Late complication of open inguinal hernia repair: small bowel obstruction caused by intraperitoneal mesh migration.

    PubMed

    Ferrone, Roberto; Scarone, Pier Carlo; Natalini, Gianni

    2003-09-01

    We describe a case of small bowel obstruction due to prosthetic mesh migration. A 67-year-old male, who had undergone prosthetic repair of inguinal hernia 3 years before, was admitted for a mechanical small bowel obstruction. Laparotomy revealed the penultimate ileal loop choked by an adhesion drawing it towards a polypropylene mesh, firmly attached to the parietal peritoneum of the inguinal region. The intestinal loop was released; the mesh was embedded deep with continuous whip suture after folding the parietal peritoneum. The patient was dismissed on the 11th postoperative day surgically healed. The "tension-free" technique is undoubtedly the gold standard for hernia repair. However, it is not free of complications, mostly due to technical errors, of which the surgeon must be aware, both when he is responsible for correcting defects in the wall, as well as when he has to face an occlusion in a patient who has undergone plastic surgery for inguinal hernia.

  18. Lightweight 3.66-meter-diameter conical mesh antenna reflector

    NASA Technical Reports Server (NTRS)

    Moore, D. M.

    1974-01-01

    A description is given of a 3.66 m diameter nonfurlable conical mesh antenna incorporating the line source feed principle recently developed. The weight of the mesh reflector and its support structure is 162 N. An area weighted RMS surface deviation of 0.28 mm was obtained. The RF performance measurements show a gain of 48.3 db at 8.448 GHz corresponding to an efficiency of 66%. During the design and development of this antenna, the technology for fabricating the large conical membranes of knitted mesh was developed. As part of this technology a FORTRAN computer program, COMESH, was developed which permits the user to predict the surface accuracy of a stretched conical membrane.

  19. Utilization of flax fibers for biomedical applications.

    PubMed

    Michel, Sophie A A X; Vogels, Ruben R M; Bouvy, Nicole D; Knetsch, Menno L W; van den Akker, Nynke M S; Gijbels, Marion J J; van der Marel, Cees; Vermeersch, Jan; Molin, Daniel G M; Koole, Leo H

    2014-04-01

    Over the past decades, a large number of animal-derived materials have been introduced for several biomedical applications. Surprisingly, the use of plant-based materials has lagged behind. To study the feasibility of plant-derived biomedical materials, we chose flax (Linum usitatissimum). Flax fibers possess excellent physical-mechanical properties, are nonbiodegradable, and there is extensive know-how on weaving/knitting of them. One area where they could be useful is as implantable mesh structures in surgery, in particular for the repair of incisional hernias of the abdominal wall. Starting with a bleached flax thread, a prototype mesh was specifically knitted for this study, and its cytocompatibility was studied in vitro and in vivo. The experimental data revealed that application of flax in surgery first requires a robust method to remove endotoxins and purify the flax fiber. Such a method was developed, and purified meshes did not cause loss of cell viability in vitro. In addition, endotoxins determined using limulus amebocyte lysate test were at acceptable levels. In vivo, the flax meshes showed only mild inflammation, comparable to commercial polypropylene meshes. This study revealed that plant-derived biomaterials can provide a new class of implantable materials that could be used as surgical meshes or for other biomedical applications. Copyright © 2013 Wiley Periodicals, Inc.

  20. Permanent Seismically Induced Displacement of Rock-Founded Structures Computed by the Newmark Program

    DTIC Science & Technology

    2009-02-01

    solved, great care is exercised by the seismic engineer to size the mesh so that moderate to high wave frequencies are not artificially excluded in...buttressing effect of a reinforced concrete slab (Figure 1.7) is represented in this simplified dynamic model by the user-specified force Presist...retaining wall that is buttressed by an invert spill- way slab (which is a reinforced concrete slab), exemplify a category of Corps retaining walls that may

  1. Donor-Site Complications and Remnant of Rectus Abdominis Muscle Status after Transverse Rectus Abdominis Myocutaneous Flap Reconstruction

    PubMed Central

    Chirappapha, Prakasit; Trikunagonvong, Noppadol; Rongthong, Sasiprapa; Lertsithichai, Panuwat; Sukarayothin, Thongchai; Leesombatpaiboon, Monchai; Panawattanakul, Rujira; Thaweepworadej, Panya

    2017-01-01

    Background: Transverse rectus abdominis myocutaneous (TRAM) flap reconstruction after mastectomy in breast cancer patients has become one of the milestones in breast reconstruction. There are several techniques that have been used in an attempt to minimize untoward complications. We present the whole muscle with partial sheath-sparing technique that focuses on the anatomy of arcuate line and the closure of the anterior abdominal wall techniques with mesh and determine factors associated with its complications and outcomes. Methods: We retrospectively and prospectively review the results of 30 pedicled TRAM flaps that were performed between November 2013 and March 2016, focusing on outcomes and complications. Results: Among the 30 pedicled TRAM flap procedures in 30 patients, there were complications in 5 patients (17%). Most common complications were surgical-site infection (7%). After a median follow-up time of 15 months, no patient developed abdominal wall hernia or bulging in daily activities in our study, but 6 patients (20%) had asymptomatic abdominal wall bulging when exercised. Significant factors related to asymptomatic exercised abdominal wall bulging included having a body mass index of more than 23 kg/m2. Conclusion: Pedicled TRAM flap by using the technique of the whole muscle with partial sheath-sparing technique combined with reinforcement above the arcuate line with mesh can reduce the occurrence of abdominal bulging and hernia. PMID:28740793

  2. Nanofiber Orientation and Surface Functionalization Modulate Human Mesenchymal Stem Cell Behavior In Vitro

    PubMed Central

    Kolambkar, Yash M.; Bajin, Mehmet; Wojtowicz, Abigail; Hutmacher, Dietmar W.; García, Andrés J.

    2014-01-01

    Electrospun nanofiber meshes have emerged as a new generation of scaffold membranes possessing a number of features suitable for tissue regeneration. One of these features is the flexibility to modify their structure and composition to orchestrate specific cellular responses. In this study, we investigated the effects of nanofiber orientation and surface functionalization on human mesenchymal stem cell (hMSC) migration and osteogenic differentiation. We used an in vitro model to examine hMSC migration into a cell-free zone on nanofiber meshes and mitomycin C treatment to assess the contribution of proliferation to the observed migration. Poly (ɛ-caprolactone) meshes with oriented topography were created by electrospinning aligned nanofibers on a rotating mandrel, while randomly oriented controls were collected on a stationary collector. Both aligned and random meshes were coated with a triple-helical, type I collagen-mimetic peptide, containing the glycine-phenylalanine-hydroxyproline-glycine-glutamate-arginine (GFOGER) motif. Our results indicate that nanofiber GFOGER peptide functionalization and orientation modulate cellular behavior, individually, and in combination. GFOGER significantly enhanced the migration, proliferation, and osteogenic differentiation of hMSCs on nanofiber meshes. Aligned nanofiber meshes displayed increased cell migration along the direction of fiber orientation compared to random meshes; however, fiber alignment did not influence osteogenic differentiation. Compared to each other, GFOGER coating resulted in a higher proliferation-driven cell migration, whereas fiber orientation appeared to generate a larger direct migratory effect. This study demonstrates that peptide surface modification and topographical cues associated with fiber alignment can be used to direct cellular behavior on nanofiber mesh scaffolds, which may be exploited for tissue regeneration. PMID:24020454

  3. A universal algorithm for an improved finite element mesh generation Mesh quality assessment in comparison to former automated mesh-generators and an analytic model.

    PubMed

    Kaminsky, Jan; Rodt, Thomas; Gharabaghi, Alireza; Forster, Jan; Brand, Gerd; Samii, Madjid

    2005-06-01

    The FE-modeling of complex anatomical structures is not solved satisfyingly so far. Voxel-based as opposed to contour-based algorithms allow an automated mesh generation based on the image data. Nonetheless their geometric precision is limited. We developed an automated mesh-generator that combines the advantages of voxel-based generation with improved representation of the geometry by displacement of nodes on the object-surface. Models of an artificial 3D-pipe-section and a skullbase were generated with different mesh-densities using the newly developed geometric, unsmoothed and smoothed voxel generators. Compared to the analytic calculation of the 3D-pipe-section model the normalized RMS error of the surface stress was 0.173-0.647 for the unsmoothed voxel models, 0.111-0.616 for the smoothed voxel models with small volume error and 0.126-0.273 for the geometric models. The highest element-energy error as a criterion for the mesh quality was 2.61x10(-2) N mm, 2.46x10(-2) N mm and 1.81x10(-2) N mm for unsmoothed, smoothed and geometric voxel models, respectively. The geometric model of the 3D-skullbase resulted in the lowest element-energy error and volume error. This algorithm also allowed the best representation of anatomical details. The presented geometric mesh-generator is universally applicable and allows an automated and accurate modeling by combining the advantages of the voxel-technique and of improved surface-modeling.

  4. Use of a novel silk mesh for ventral midline hernioplasty in a mare.

    PubMed

    Haupt, Jennifer; García-López, José M; Chope, Kate

    2015-03-13

    Ventral midline hernia formation following abdominal surgery in horses is an uncommon complication; however, it can have serious consequences leading to increased morbidity and mortality. Currently, mesh hernioplasty is the treatment of choice for large ventral midline hernias in horses to allow potential return to normal function. Complications following mesh hernioplasty using polypropylene or polyester mesh in horses can be serious and similar to complications seen in human patients, including persistent incisional drainage, mesh infection, hernia recurrence, intra-abdominal adhesions, mesh or body wall failure, recurrent abdominal pain (colic), and peritonitis. This report describes the use of a novel bioresorbable silk mesh for repair of a large ventral midline incisional hernia in a mature, 600-kg horse. To our knowledge, this is the first report of its kind in the literature. A 9-year-old, 600-kg Warmblood mare presented with a ventral midline hernia following emergency exploratory celiotomy 20 months prior. The mare was anesthetized and a hernioplasty was performed using a novel bioresorbable silk mesh (SERI(®) Surgical Scaffold; Allergan Medical, Boston, MA). No complications were encountered either intra- or postoperatively. The mare was discharged from the hospital at 3 days postoperatively in an abdominal support bandage. At 8 and 20 weeks postoperatively, ultrasonographic assessment showed evidence of tissue ingrowth within and around the mesh. The mare was able to be bred 2 years in a row, carrying both foals to full gestation with no complications. Following both foalings, the abdomen has maintained a normal contour with no evidence of hernia recurrence. Ventral abdominal hernias can be repaired in horses using a bioresorbable silk mesh, which provides adequate biomechanical strength while allowing for fibrous tissue ingrowth. The use of a bioresorbable silk mesh for the repair of ventral hernias can be considered as a realistic option as it potentially provides significant benefits over traditional non-resorbable mesh.

  5. Fabrication of a novel superhydrophobic and superoleophilic surface by one-step electrodeposition method for continuous oil/water separation

    NASA Astrophysics Data System (ADS)

    Xiang, Meisu; Jiang, Meihuizi; Zhang, Yanzong; Liu, Yan; Shen, Fei; Yang, Gang; He, Yan; Wang, Lilin; Zhang, Xiaohong; Deng, Shihuai

    2018-03-01

    A novel superhydrophobic and superoleophilic surface was fabricated by one-step electrodeposition on stainless steel meshes, and the durability and oil/water separation properties were assessed. Field emission scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), fourier transform infrared spectroscopy (FT-IR) and optical contact angle measurements were used to characterize surface morphologies, chemical compositions, and wettabilities, respectively. The results indicated that the as-prepared mesh preformed excellent superhydrophobicity and superoleophilicity with a high water contact angle (WCA) of 162 ± 1° and oil contact angle of (OCA) 0°. Meanwhile, the as-prepared mesh also exhibited continuous separation capacity of many kinds of oil/water mixtures, and the separation efficiency for lubrication oil/water mixture was about 98.6%. In addition, after 10 separation cycles, the as-prepared mesh possessed the WCAs of 155 ± 2°, the OCAs of 0° and the separation efficiency of 97.8% for lubrication oil/water mixtures. The as-prepared mesh also retained superhydrophobic and superoleophilic properties after abrading, immersing in salt solutions and different pH solutions.

  6. Automated quadrilateral surface discretization method and apparatus usable to generate mesh in a finite element analysis system

    DOEpatents

    Blacker, Teddy D.

    1994-01-01

    An automatic quadrilateral surface discretization method and apparatus is provided for automatically discretizing a geometric region without decomposing the region. The automated quadrilateral surface discretization method and apparatus automatically generates a mesh of all quadrilateral elements which is particularly useful in finite element analysis. The generated mesh of all quadrilateral elements is boundary sensitive, orientation insensitive and has few irregular nodes on the boundary. A permanent boundary of the geometric region is input and rows are iteratively layered toward the interior of the geometric region. Also, an exterior permanent boundary and an interior permanent boundary for a geometric region may be input and the rows are iteratively layered inward from the exterior boundary in a first counter clockwise direction while the rows are iteratively layered from the interior permanent boundary toward the exterior of the region in a second clockwise direction. As a result, a high quality mesh for an arbitrary geometry may be generated with a technique that is robust and fast for complex geometric regions and extreme mesh gradations.

  7. Generating a Simulated Fluid Flow Over an Aircraft Surface Using Anisotropic Diffusion

    NASA Technical Reports Server (NTRS)

    Rodriguez, David L. (Inventor); Sturdza, Peter (Inventor)

    2013-01-01

    A fluid-flow simulation over a computer-generated aircraft surface is generated using a diffusion technique. The surface is comprised of a surface mesh of polygons. A boundary-layer fluid property is obtained for a subset of the polygons of the surface mesh. A pressure-gradient vector is determined for a selected polygon, the selected polygon belonging to the surface mesh but not one of the subset of polygons. A maximum and minimum diffusion rate is determined along directions determined using a pressure gradient vector corresponding to the selected polygon. A diffusion-path vector is defined between a point in the selected polygon and a neighboring point in a neighboring polygon. An updated fluid property is determined for the selected polygon using a variable diffusion rate, the variable diffusion rate based on the minimum diffusion rate, maximum diffusion rate, and angular difference between the diffusion-path vector and the pressure-gradient vector.

  8. A New Formulation of Time Domain Boundary Integral Equation for Acoustic Wave Scattering in the Presence of a Uniform Mean Flow

    NASA Technical Reports Server (NTRS)

    Hu, Fang; Pizzo, Michelle E.; Nark, Douglas M.

    2017-01-01

    It has been well-known that under the assumption of a constant uniform mean flow, the acoustic wave propagation equation can be formulated as a boundary integral equation, in both the time domain and the frequency domain. Compared with solving partial differential equations, numerical methods based on the boundary integral equation have the advantage of a reduced spatial dimension and, hence, requiring only a surface mesh. However, the constant uniform mean flow assumption, while convenient for formulating the integral equation, does not satisfy the solid wall boundary condition wherever the body surface is not aligned with the uniform mean flow. In this paper, we argue that the proper boundary condition for the acoustic wave should not have its normal velocity be zero everywhere on the solid surfaces, as has been applied in the literature. A careful study of the acoustic energy conservation equation is presented that shows such a boundary condition in fact leads to erroneous source or sink points on solid surfaces not aligned with the mean flow. A new solid wall boundary condition is proposed that conserves the acoustic energy and a new time domain boundary integral equation is derived. In addition to conserving the acoustic energy, another significant advantage of the new equation is that it is considerably simpler than previous formulations. In particular, tangential derivatives of the solution on the solid surfaces are no longer needed in the new formulation, which greatly simplifies numerical implementation. Furthermore, stabilization of the new integral equation by Burton-Miller type reformulation is presented. The stability of the new formulation is studied theoretically as well as numerically by an eigenvalue analysis. Numerical solutions are also presented that demonstrate the stability of the new formulation.

  9. Reentry-Vehicle Shape Optimization Using a Cartesian Adjoint Method and CAD Geometry

    NASA Technical Reports Server (NTRS)

    Nemec, Marian; Aftosmis, Michael J.

    2006-01-01

    A DJOINT solutions of the governing flow equations are becoming increasingly important for the development of efficient analysis and optimization algorithms. A well-known use of the adjoint method is gradient-based shape. Given an objective function that defines some measure of performance, such as the lift and drag functionals, its gradient is computed at a cost that is essentially independent of the number of design variables (e.g., geometric parameters that control the shape). Classic aerodynamic applications of gradient-based optimization include the design of cruise configurations for transonic and supersonic flow, as well as the design of high-lift systems. are perhaps the most promising approach for addressing the issues of flow solution automation for aerodynamic design problems. In these methods, the discretization of the wetted surface is decoupled from that of the volume mesh. This not only enables fast and robust mesh generation for geometry of arbitrary complexity, but also facilitates access to geometry modeling and manipulation using parametric computer-aided design (CAD). In previous work on Cartesian adjoint solvers, Melvin et al. developed an adjoint formulation for the TRANAIR code, which is based on the full-potential equation with viscous corrections. More recently, Dadone and Grossman presented an adjoint formulation for the two-dimensional Euler equations using a ghost-cell method to enforce the wall boundary conditions. In Refs. 18 and 19, we presented an accurate and efficient algorithm for the solution of the adjoint Euler equations discretized on Cartesian meshes with embedded, cut-cell boundaries. Novel aspects of the algorithm were the computation of surface shape sensitivities for triangulations based on parametric-CAD models and the linearization of the coupling between the surface triangulation and the cut-cells. The accuracy of the gradient computation was verified using several three-dimensional test cases, which included design variables such as the free stream parameters and the planform shape of an isolated wing. The objective of the present work is to extend our adjoint formulation to problems involving general shape changes. Factors under consideration include the computation of mesh sensitivities that provide a reliable approximation of the objective function gradient, as well as the computation of surface shape sensitivities based on a direct-CAD interface. We present detailed gradient verification studies and then focus on a shape optimization problem for an Apollo-like reentry vehicle. The goal of the optimization is to enhance the lift-to-drag ratio of the capsule by modifying the shape of its heat-shield in conjunction with a center-of-gravity (c.g.) offset. This multipoint and multi-objective optimization problem is used to demonstrate the overall effectiveness of the Cartesian adjoint method for addressing the issues of complex aerodynamic design.

  10. A Mechanistic Study of Wetting Superhydrophobic Porous 3D Meshes

    PubMed Central

    Yohe, Stefan T.; Freedman, Jonathan D.; Falde, Eric J.; Colson, Yolonda L.; Grinstaff, Mark W.

    2014-01-01

    Superhydrophobic, porous, 3D materials composed of poly( ε -caprolactone) (PCL) and the hydrophobic polymer dopant poly(glycerol monostearate-co- ε -caprolactone) (PGC-C18) are fabricated using the electrospinning technique. These 3D materials are distinct from 2D superhydrophobic surfaces, with maintenance of air at the surface as well as within the bulk of the material. These superhydrophobic materials float in water, and when held underwater and pressed, an air bubble is released and will rise to the surface. By changing the PGC-C18 doping concentration in the meshes and/or the fiber size from the micro- to nanoscale, the long-term stability of the entrapped air layer is controlled. The rate of water infiltration into the meshes, and the resulting displacement of the entrapped air, is quantitatively measured using X-ray computed tomography. The properties of the meshes are further probed using surfactants and solvents of different surface tensions. Finally, the application of hydraulic pressure is used to quantify the breakthrough pressure to wet the meshes. The tools for fabrication and analysis of these superhydrophobic materials as well as the ability to control the robustness of the entrapped air layer are highly desirable for a number of existing and emerging applications. PMID:25309305

  11. Preparation and biocompatibility evaluation of polypropylene mesh coated with electrospinning membrane for pelvic defects repair.

    PubMed

    Lu, Yao; Fu, Shaoju; Zhou, Shuanglin; Chen, Ge; Zhu, Chaoting; Li, Nannan; Ma, Ying

    2018-05-01

    Composite mesh with different materials composition could compensate for the drawbacks brought by single component mesh. Coating a membrane layer on the surface of macroporous mesh is a common method for preparing composite medical mesh. Electrospinning and dipping methods were introduced to form the two kinds of membrane-coated PP meshes (electro-mesh and dip-mesh); several properties were measured based on subcutaneous implantation model in rat. The results revealed that continuous tissue ingrowth could be observed for electro-mesh only with evidences of strength increase (electro-mesh: 0 week - 13.1 ± 0.88 N, 2 week - 16.87 ± 1.39 N, 4 week - 22.04 ± 2.05 N) and thickness increase (electro-mesh: 0 week - 0.437 ± 0.023 mm, 2 week - 0.488 ± 0.025 mm, 4 week - 0.576 ± 0.028 mm). However, no tissues were observed for dip-mesh in the first 2 weeks, both on macroscopic level and microscopic level, proved by strength data (dip-mesh: 0 week - 13.36 ± 1.06 N, 2 week - 13.4 ± 1.33 N, 4 week - 18.61 ± 1.89 N) and thickness data (dip-mesh: 0 week - 0.439 ± 0.018 mm, 2 week - 0.439 ± 0.019 mm, 4 week - 0.502 ± 0.032 mm). Electro-mesh had larger surface area decrease (10.74 ± 1.22%) than that of dip-mesh (2.78 ± 0.52%). The adhesion level of electro-mesh (medium adhesion) was also higher than that of dip-mesh (mild adhesion). Even if showing differences in several properties, both meshes were similar under histological observation, with the ability to support fresh tissues ingrowth. Considering operation environment, electro-mesh seems more suitable than dip-mesh with a rapid tissue growing, medium adhesion rate for repairing pelvic floor defects. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. A Tissue Relevance and Meshing Method for Computing Patient-Specific Anatomical Models in Endoscopic Sinus Surgery Simulation

    NASA Astrophysics Data System (ADS)

    Audette, M. A.; Hertel, I.; Burgert, O.; Strauss, G.

    This paper presents on-going work on a method for determining which subvolumes of a patient-specific tissue map, extracted from CT data of the head, are relevant to simulating endoscopic sinus surgery of that individual, and for decomposing these relevant tissues into triangles and tetrahedra whose mesh size is well controlled. The overall goal is to limit the complexity of the real-time biomechanical interaction while ensuring the clinical relevance of the simulation. Relevant tissues are determined as the union of the pathology present in the patient, of critical tissues deemed to be near the intended surgical path or pathology, and of bone and soft tissue near the intended path, pathology or critical tissues. The processing of tissues, prior to meshing, is based on the Fast Marching method applied under various guises, in a conditional manner that is related to tissue classes. The meshing is based on an adaptation of a meshing method of ours, which combines the Marching Tetrahedra method and the discrete Simplex mesh surface model to produce a topologically faithful surface mesh with well controlled edge and face size as a first stage, and Almost-regular Tetrahedralization of the same prescribed mesh size as a last stage.

  13. Gas reservoir and a method to supply gas to plasma tubes

    DOEpatents

    Stautner, Ernst Wolfgang; Michael, Joseph Darryl

    2017-01-31

    A reservoir for storing and supplying a portion of a reservoir gas into a gas-filled tube is presented. The reservoir includes a first vessel having a thermally conductive surface, a meshed vessel having a lid, and placed inside the first vessel to form a cavity between the meshed vessel and the first vessel, at least one tray placed inside the meshed vessel to divide an inner space of the meshed vessel into a plurality of compartments, a sorbent material placed inside the plurality of compartments in the meshed vessel, a temperature control device positioned such that a first portion of the temperature control device is in physical contact with at least a portion of the thermally conductive surface, and a change in the temperature of the temperature control device changes the temperature of the sorbent material, wherein the reservoir gas is retained by the sorbent material at the storage temperature.

  14. Experimental Investigation of Thermal Performance of Miniature Heat Pipe Using SiO2-Water Nanofluids.

    PubMed

    Niu, Yan-Fang; Zhao, Wei-Lin; Gong, Yu-Ying

    2015-04-01

    The four miniature heat pipes filled with DI water and SiO2-water nanofluids containing different volume concentrations (0.2%, 0.6% and 1.0%) are experimentally measured on the condition of air and water cooling. The wall temperature and the thermal resistance are investigated for three inclination angles. At the same of inlet heat water temperature in the heat system, it is observed that the total wall temperatures on the evaporator section are almost retaining constant by air cooling and the wall temperatures at the front end of the evaporator section are slightly reduced by water cooling. However, the wall temperatures at the condenser section using SiO2-water nanofluids are all higher than that for DI water on the two cooling conditions. As compared with the heat pipe using DI water, the decreasing of the thermal resistance in heat pipe using nanofluids is about 43.10%-74.46% by air cooling and 51.43%-72.22% by water cooling. These indicate that the utilization of SiO2-water nanofluids as working fluids enhances the performance of the miniature heat pipe. When the four miniature heat pipes are cut to examine at the end of the experiment, a thin coating on the surface of the screen mesh of the heat pipe using SiO2-water nanofluids is found. This may be one reason for reinforcing the heat transfer performance of the miniature heat pipe.

  15. Finite-element 3D simulation tools for high-current relativistic electron beams

    NASA Astrophysics Data System (ADS)

    Humphries, Stanley; Ekdahl, Carl

    2002-08-01

    The DARHT second-axis injector is a challenge for computer simulations. Electrons are subject to strong beam-generated forces. The fields are fully three-dimensional and accurate calculations at surfaces are critical. We describe methods applied in OmniTrak, a 3D finite-element code suite that can address DARHT and the full range of charged-particle devices. The system handles mesh generation, electrostatics, magnetostatics and self-consistent particle orbits. The MetaMesh program generates meshes of conformal hexahedrons to fit any user geometry. The code has the unique ability to create structured conformal meshes with cubic logic. Organized meshes offer advantages in speed and memory utilization in the orbit and field solutions. OmniTrak is a versatile charged-particle code that handles 3D electric and magnetic field solutions on independent meshes. The program can update both 3D field solutions from the calculated beam space-charge and current-density. We shall describe numerical methods for orbit tracking on a hexahedron mesh. Topics include: 1) identification of elements along the particle trajectory, 2) fast searches and adaptive field calculations, 3) interpolation methods to terminate orbits on material surfaces, 4) automatic particle generation on multiple emission surfaces to model space-charge-limited emission and field emission, 5) flexible Child law algorithms, 6) implementation of the dual potential model for 3D magnetostatics, and 7) assignment of charge and current from model particle orbits for self-consistent fields.

  16. Recent Development in the CESE Method for the Solution of the Navier-Stokes Equations Using Unstructured Triangular or Tetrahedral Meshes With High Aspect Ratio

    NASA Technical Reports Server (NTRS)

    Chang, Sin-Chung; Chang, Chau-Lyan; Yen, Joseph C.

    2013-01-01

    In the multidimensional CESE development, triangles and tetrahedra turn out to be the most natural building blocks for 2D and 3D spatial meshes. As such the CESE method is compatible with the simplest unstructured meshes and thus can be easily applied to solve problems with complex geometries. However, because the method uses space-time staggered stencils, solution decoupling may become a real nuisance in applications involving unstructured meshes. In this paper we will describe a simple and general remedy which, according to numerical experiments, has removed any possibility of solution decoupling. Moreover, in a real-world viscous flow simulation near a solid wall, one often encounters a case where a boundary with high curvature or sharp corner is surrounded by triangular/tetrahedral meshes of extremely high aspect ratio (up to 106). For such an extreme case, the spatial projection of a space-time compounded conservation element constructed using the original CESE design may become highly concave and thus its centroid (referred to as a spatial solution point) may lie far outside of the spatial projection. It could even be embedded beyond a solid wall boundary and causes serious numerical difficulties. In this paper we will also present a new procedure for constructing conservation elements and solution elements which effectively overcomes the difficulties associated with the original design. Another difficulty issue which was addressed more recently is the wellknown fact that accuracy of gradient computations involving triangular/tetrahedral grids deteriorates rapidly as the aspect ratio of grid cells increases. The root cause of this difficulty was clearly identified and several remedies to overcome it were found through a rigorous mathematical analysis. However, because of the length of the current paper and the complexity of mathematics involved, this new work will be presented in another paper.

  17. Risk factors of surgical failure following sacrospinous colpopexy for the treatment of uterovaginal prolapse.

    PubMed

    Qatawneh, Ayman; Thekrallah, Fida; Bata, Majed; Al-Kazaleh, Fawaz; Almustafa, Mahmoud; Abu-Kader, Ilham

    2013-06-01

    Trans-vaginal sacrospinous colpopexy is one of the surgical procedures used to repair varying degrees of vaginal vault and uterovaginal prolapse. The purpose of this study is to analyse the potential risk factors of surgical failure following sacrospinous colpopexy. A retrospective study of 114 women who underwent unilateral sacrospinous colpopexy at Jordan University Hospital from January 2005 to January 2008 were included. Patient demographics, clinical characteristics and concomitant pelvic organ prolapse surgery were assessed. The patients were evaluated at 6 weeks, and every 6 months thereafter. Twelve (11 %) had recurrent apical (vaginal cuff) prolapse, 26 (23 %) had recurrent prolapse at any compartment were compared with those who had successful surgery. Univariate and logistic regression analyses were used to assess the independent prognostic values of the variables associated with surgical failure. After a mean follow-up of 40 months, the statistically significant predictors of surgical failure included the presence of advanced pre-operative stages of prolapse (stages III and IV), the more distally located points Ba, Bp and C and a lack of mesh augmentation of the anterior vaginal wall during surgery (P = 0.01, 0.027, 0.024, 0.034 and 0.006, respectively). However, a history of prior vaginal repair, the more distally located point Ba and a lack of anterior vaginal wall mesh augmentation were defined as independent predictive variables based on logistic regression analyses (P = 0.04, 0.005 and 0.046, respectively). The presence of advanced anterior vaginal wall prolapse, prior vaginal repair and a lack of mesh augmentation of the anterior compartment are significant risk factors for the surgical failure of sacrospinous suspension surgery.

  18. A particle-based model to simulate the micromechanics of single-plant parenchyma cells and aggregates

    NASA Astrophysics Data System (ADS)

    Van Liedekerke, P.; Ghysels, P.; Tijskens, E.; Samaey, G.; Smeedts, B.; Roose, D.; Ramon, H.

    2010-06-01

    This paper is concerned with addressing how plant tissue mechanics is related to the micromechanics of cells. To this end, we propose a mesh-free particle method to simulate the mechanics of both individual plant cells (parenchyma) and cell aggregates in response to external stresses. The model considers two important features in the plant cell: (1) the cell protoplasm, the interior liquid phase inducing hydrodynamic phenomena, and (2) the cell wall material, a viscoelastic solid material that contains the protoplasm. In this particle framework, the cell fluid is modeled by smoothed particle hydrodynamics (SPH), a mesh-free method typically used to address problems with gas and fluid dynamics. In the solid phase (cell wall) on the other hand, the particles are connected by pairwise interactions holding them together and preventing the fluid to penetrate the cell wall. The cell wall hydraulic conductivity (permeability) is built in as well through the SPH formulation. Although this model is also meant to be able to deal with dynamic and even violent situations (leading to cell wall rupture or cell-cell debonding), we have concentrated on quasi-static conditions. The results of single-cell compression simulations show that the conclusions found by analytical models and experiments can be reproduced at least qualitatively. Relaxation tests revealed that plant cells have short relaxation times (1 µs-10 µs) compared to mammalian cells. Simulations performed on cell aggregates indicated an influence of the cellular organization to the tissue response, as was also observed in experiments done on tissues with a similar structure.

  19. Biaxial Mechanical Evaluation of Absorbable and Nonabsorbable Synthetic Surgical Meshes Used for Hernia Repair: Physiological Loads Modify Anisotropy Response.

    PubMed

    Cordero, A; Hernández-Gascón, B; Pascual, G; Bellón, J M; Calvo, B; Peña, E

    2016-07-01

    The aim of this study was to obtain information about the mechanical properties of six meshes commonly used for hernia repair (Surgipro(®), Optilene(®), Infinit(®), DynaMesh(®), Ultrapro™ and TIGR(®)) by planar biaxial tests. Stress-stretch behavior and equibiaxial stiffness were evaluated, and the anisotropy was determined by testing. In particular, equibiaxial test (equal simultaneous loading in both directions) and biaxial test (half of the load in one direction following the Laplace law) were selected as a representation of physiologically relevant loads. The majority of the meshes displayed values in the range of 8 and 18 (N/mm) in each direction for equibiaxial stiffness (tangent modulus under equibiaxial load state in both directions), while a few achieved 28 and 50 (N/mm) (Infinit (®) and TIGR (®)). Only the Surgipro (®) mesh exhibited planar isotropy, with similar mechanical properties regardless of the direction of loading, and an anisotropy ratio of 1.18. Optilene (®), DynaMesh (®), Ultrapro (®) and TIGR (®) exhibited moderate anisotropy with ratios of 1.82, 1.84, 2.17 and 1.47, respectively. The Infinit (®) scaffold exhibited very high anisotropy with a ratio of 3.37. These trends in material anisotropic response changed during the physiological state in the human abdominal wall, i.e. T:0.5T test, which the meshes were loaded in one direction with half the load used in the other direction. The Surgipro (®) mesh increased its anisotropic response (Anis[Formula: see text] = 0.478) and the materials that demonstrated moderate and high anisotropic responses during multiaxial testing presented a quasi-isotropic response, especially the Infinit(®) mesh that decreased its anisotropic response from 3.369 to 1.292.

  20. Coated mesh photocatalytic reactor for air treatment applications: comparative study of support materials.

    PubMed

    Passalía, Claudio; Nocetti, Emanuel; Alfano, Orlando; Brandi, Rodolfo

    2017-03-01

    An experimental comparative study of different meshes as support materials for photocatalytic applications in gas phase is presented. The photocatalytic oxidation of dichloromethane in air was addressed employing different coated meshes in a laboratory-scale, continuous reactor. Two fiberglass meshes and a stainless steel mesh were studied regarding the catalyst load, adherence, and catalytic activity. Titanium dioxide photocatalyst was immobilized on the meshes by dip-coating cycles. Results indicate the feasibility of the dichloromethane elimination in the three cases. When the number of coating cycles was doubled, the achieved conversion levels were increased twofold for stainless steel and threefold for the fiberglass meshes. One of the fiberglass meshes (FG2) showed the highest reactivity per mass of catalyst and per catalytic surface area.

  1. Multi-Shock Shield Performance at 15 MJ for Catalogued Debris

    NASA Technical Reports Server (NTRS)

    Miller, J. E.; Davis, B. A.; Christiansen, E. L.; Lear, D. M.

    2015-01-01

    While orbital debris of ten centimeters or more are tracked and catalogued, the difficulty of finding and accurately accounting for forces acting on the objects near the ten centimeter threshold results in both uncertainty of their presence and location. These challenges result in difficult decisions for operators balancing potential costly operational approaches with system loss risk. In this paper, the assessment of the feasibility of protecting a spacecraft from this catalogued debris is described using numerical simulations and a test of a multi-shock shield system against a cylindrical projectile impacting normal to the surface with approximately 15 MJ of kinetic energy. The hypervelocity impact test has been conducted at the Arnold Engineering Development Complex (AEDC) with a 598 g projectile at 6.905 km/s on a NASA supplied multi-shock shield. The projectile used is a hollow aluminum and nylon cylinder with an outside diameter of 8.6 cm and length of 10.3 cm. Figure 1 illustrates the multi-shock shield test article, which consisted of five separate bumpers, four of which are fiberglass fabric and one of steel mesh, and two rear walls, each consisting of Kevlar fabric. The overall length of the test article was 2.65 m. The test article was a 5X scaled-up version of a smaller multi-shock shield previously tested using a 1.4 cm diameter aluminum projectile for an inflatable module project. The distances represented by S1 and S1/2 in the figure are 61 cm and 30.5 cm, respectively. Prior to the impact test, hydrodynamic simulations indicated that some enhancement to the standard multi-shock system is needed to address the effects of the cylindrical shape of the projectile. Based on the simulations, a steel mesh bumper has been added to the shield configuration to enhance the fragmentation of the projectile. The AEDC test occurred as planned, and the modified NASA multi-shock shield successfully stopped 598 g projectile using 85.6 kg/m(exp 2). The fifth bumper layer remained in tact, although it was torn free from its support structure and thrown into the first rear wall. The outer Kevlar layer of the first rear wall tore likely from the impact of the fifth bumper's support structure, but the back of the rear wall was intact. No damage occurred to the second rear wall, or to the witness plate behind the target.

  2. Modeling Radiation Effects on a Triple Junction Solar Cell using Silvaco ATLAS

    DTIC Science & Technology

    2012-06-01

    circuit voltage can then be calculated from ln 1 Loc t S IV V I        (4.3) where IS is the reverse saturation current, and Vt is the...orbiting electronic equipment. The first orbit of interest is the low Earth orbit ( LEO ). LEO encompasses any orbit within 650 kilometers of the...Light Beams #Solving #Meshing mesh width=200000 #X-Mesh: Surface=500 um2 = 1/200000 cm2 x.mesh loc =-250 spac=50 x.mesh loc =0 spac=10

  3. Reference Computational Meshing Strategy for Computational Fluid Dynamics Simulation of Departure from Nucleate BoilingReference Computational Meshing Strategy for Computational Fluid Dynamics Simulation of Departure from Nucleate Boiling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pointer, William David

    The objective of this effort is to establish a strategy and process for generation of suitable computational mesh for computational fluid dynamics simulations of departure from nucleate boiling in a 5 by 5 fuel rod assembly held in place by PWR mixing vane spacer grids. This mesh generation process will support ongoing efforts to develop, demonstrate and validate advanced multi-phase computational fluid dynamics methods that enable more robust identification of dryout conditions and DNB occurrence.Building upon prior efforts and experience, multiple computational meshes were developed using the native mesh generation capabilities of the commercial CFD code STAR-CCM+. These meshes weremore » used to simulate two test cases from the Westinghouse 5 by 5 rod bundle facility. The sensitivity of predicted quantities of interest to the mesh resolution was then established using two evaluation methods, the Grid Convergence Index method and the Least Squares method. This evaluation suggests that the Least Squares method can reliably establish the uncertainty associated with local parameters such as vector velocity components at a point in the domain or surface averaged quantities such as outlet velocity magnitude. However, neither method is suitable for characterization of uncertainty in global extrema such as peak fuel surface temperature, primarily because such parameters are not necessarily associated with a fixed point in space. This shortcoming is significant because the current generation algorithm for identification of DNB event conditions relies on identification of such global extrema. Ongoing efforts to identify DNB based on local surface conditions will address this challenge« less

  4. Improvements to the Unstructured Mesh Generator MESH3D

    NASA Technical Reports Server (NTRS)

    Thomas, Scott D.; Baker, Timothy J.; Cliff, Susan E.

    1999-01-01

    The AIRPLANE process starts with an aircraft geometry stored in a CAD system. The surface is modeled with a mesh of triangles and then the flow solver produces pressures at surface points which may be integrated to find forces and moments. The biggest advantage is that the grid generation bottleneck of the CFD process is eliminated when an unstructured tetrahedral mesh is used. MESH3D is the key to turning around the first analysis of a CAD geometry in days instead of weeks. The flow solver part of AIRPLANE has proven to be robust and accurate over a decade of use at NASA. It has been extensively validated with experimental data and compares well with other Euler flow solvers. AIRPLANE has been applied to all the HSR geometries treated at Ames over the course of the HSR program in order to verify the accuracy of other flow solvers. The unstructured approach makes handling complete and complex geometries very simple because only the surface of the aircraft needs to be discretized, i.e. covered with triangles. The volume mesh is created automatically by MESH3D. AIRPLANE runs well on multiple platforms. Vectorization on the Cray Y-MP is reasonable for a code that uses indirect addressing. Massively parallel computers such as the IBM SP2, SGI Origin 2000, and the Cray T3E have been used with an MPI version of the flow solver and the code scales very well on these systems. AIRPLANE can run on a desktop computer as well. AIRPLANE has a future. The unstructured technologies developed as part of the HSR program are now targeting high Reynolds number viscous flow simulation. The pacing item in this effort is Navier-Stokes mesh generation.

  5. Preclinical animal study and human clinical trial data of co-electrospun poly(l-lactide-co-caprolactone) and fibrinogen mesh for anterior pelvic floor reconstruction

    PubMed Central

    Wu, Xujun; Wang, Yuru; Zhu, Cancan; Tong, Xiaowen; Yang, Ming; Yang, Li; Liu, Zhang; Huang, Weihong; Wu, Feng; Zong, Honghai; Li, Huaifang; He, Hongbing

    2016-01-01

    Synthetic and biological materials are commonly used for pelvic floor reconstruction. In this study, host tissue response and biomechanical properties of mesh fabricated from co-electrospun poly(l-lactide-co-caprolactone) (PLCL) and fibrinogen (Fg) were compared with those of polypropylene mesh (PPM) in a canine abdominal defect model. Macroscopic, microscopic, histological, and biomechanical evaluations were performed over a 24-week period. The results showed that PLCL/Fg mesh had similar host tissue responses but better initial vascularization and graft site tissue organization than PPM. The efficacy of the PLCL/Fg mesh was further examined in human pelvic floor reconstruction. Operation time, intraoperative blood loss, and pelvic organ prolapse quantification during 6-month follow-up were compared for patients receiving PLCL/Fg mesh versus PPM. According to the pelvic organ prolapse quantification scores, the anterior vaginal wall 3 cm proximal to the hymen point (Aa point), most distal edge of the cervix or vaginal cuff scar point (C point), and posterior fornix point (D point) showed significant improvement (P<0.01) at 1, 3, and 6 months for both groups compared with preoperatively. At 6 months, improvements at the Aa point in the PLCL/Fg group were significantly more (P<0.005) than the PPM group, indicating that, while both materials improve the patient symptoms, PLCL/Fg mesh resulted in more obvious improvement. PMID:26893556

  6. LES on unstructured deforming meshes: Towards reciprocating IC engines

    NASA Technical Reports Server (NTRS)

    Haworth, D. C.; Jansen, K.

    1996-01-01

    A variable explicit/implicit characteristics-based advection scheme that is second-order accurate in space and time has been developed recently for unstructured deforming meshes (O'Rourke & Sahota 1996a). To explore the suitability of this methodology for Large-Eddy Simulation (LES), three subgrid-scale turbulence models have been implemented in the CHAD CFD code (O'Rourke & Sahota 1996b): a constant-coefficient Smagorinsky model, a dynamic Smagorinsky model for flows having one or more directions of statistical homogeneity, and a Lagrangian dynamic Smagorinsky model for flows having no spatial or temporal homogeneity (Meneveau et al. 1996). Computations have been made for three canonical flows, progressing towards the intended application of in-cylinder flow in a reciprocating engine. Grid sizes were selected to be comparable to the coarsest meshes used in earlier spectral LES studies. Quantitative results are reported for decaying homogeneous isotropic turbulence, and for a planar channel flow. Computations are compared to experimental measurements, to Direct-Numerical Simulation (DNS) data, and to Rapid-Distortion Theory (RDT) where appropriate. Generally satisfactory evolution of first and second moments is found on these coarse meshes; deviations are attributed to insufficient mesh resolution. Issues include mesh resolution and computational requirements for a specified level of accuracy, analytic characterization of the filtering implied by the numerical method, wall treatment, and inflow boundary conditions. To resolve these issues, finer-mesh simulations and computations of a simplified axisymmetric reciprocating piston-cylinder assembly are in progress.

  7. Reversible switch between underwater superaerophilicity and superaerophobicity on the superhydrophobic nanowire-haired mesh for controlling underwater bubble wettability

    NASA Astrophysics Data System (ADS)

    Shan, Chao; Yong, Jiale; Yang, Qing; Chen, Feng; Huo, Jinglan; Zhuang, Jian; Jiang, Zhuangde; Hou, Xun

    2018-04-01

    Controlling the underwater bubble wettability on a solid surface is of great research significance. In this letter, a simple method to achieve reversible switch between underwater superaerophilicity and underwater superaerophobicity on a superhydrophobic nanowire-haired mesh by alternately vacuumizing treatment in water and drying in air is reported. Such reversible switch endows the as-prepared mesh with many functional applications in controlling bubble's behavior on a solid substrate. The underwater superaerophilic mesh is able to absorb/capture bubbles in water, while the superaerophobic mesh has great anti-bubble ability. The reversible switch between underwater superaerophilicity and superaerophobicity can selectively allow bubbles to go through the resultant mesh; that is, bubbles can pass through the underwater superaerophilic mesh while are fully intercepted by the underwater superaerophobic mesh in a water medium. We believe these meshes will have important applications in removing or capturing underwater bubbles/gas.

  8. A Novel Haptic Interactive Approach to Simulation of Surgery Cutting Based on Mesh and Meshless Models

    PubMed Central

    Liu, Peter X.; Lai, Pinhua; Xu, Shaoping; Zou, Yanni

    2018-01-01

    In the present work, the majority of implemented virtual surgery simulation systems have been based on either a mesh or meshless strategy with regard to soft tissue modelling. To take full advantage of the mesh and meshless models, a novel coupled soft tissue cutting model is proposed. Specifically, the reconstructed virtual soft tissue consists of two essential components. One is associated with surface mesh that is convenient for surface rendering and the other with internal meshless point elements that is used to calculate the force feedback during cutting. To combine two components in a seamless way, virtual points are introduced. During the simulation of cutting, the Bezier curve is used to characterize smooth and vivid incision on the surface mesh. At the same time, the deformation of internal soft tissue caused by cutting operation can be treated as displacements of the internal point elements. Furthermore, we discussed and proved the stability and convergence of the proposed approach theoretically. The real biomechanical tests verified the validity of the introduced model. And the simulation experiments show that the proposed approach offers high computational efficiency and good visual effect, enabling cutting of soft tissue with high stability. PMID:29850006

  9. Calculation of Water Entry Problem for Free-falling Bodies Using a Developed Cartesian Cut Cell Mesh

    NASA Astrophysics Data System (ADS)

    Wenhua, Wang; Yanying, Wang

    2010-05-01

    This paper describes the development of free surface capturing method on Cartesian cut cell mesh to water entry problem for free-falling bodies with body-fluid interaction. The incompressible Euler equations for a variable density fluid system are presented as governing equations and the free surface is treated as a contact discontinuity by using free surface capturing method. In order to be convenient for dealing with the problem with moving body boundary, the Cartesian cut cell technique is adopted for generating the boundary-fitted mesh around body edge by cutting solid regions out of a background Cartesian mesh. Based on this mesh system, governing equations are discretized by finite volume method, and at each cell edge inviscid flux is evaluated by means of Roe's approximate Riemann solver. Furthermore, for unsteady calculation in time domain, a time accurate solution is achieved by a dual time-stepping technique with artificial compressibility method. For the body-fluid interaction, the projection method of momentum equations and exact Riemann solution are applied in the calculation of fluid pressure on the solid boundary. Finally, the method is validated by test case of water entry for free-falling bodies.

  10. Operative correction of abdominal rectus diastasis (ARD) reduces pain and improves abdominal wall muscle strength: A randomized, prospective trial comparing retromuscular mesh repair to double-row, self-retaining sutures.

    PubMed

    Emanuelsson, Peter; Gunnarsson, Ulf; Dahlstrand, Ursula; Strigård, Karin; Stark, Birgit

    2016-11-01

    The primary aim of this prospective, randomized, clinical, 2-armed trial was to evaluate the risk for recurrence using 2 different operative techniques for repair of abdominal rectus diastasis. Secondary aims were comparison of pain, abdominal muscle strength, and quality of life and to compare those outcomes to a control group receiving physical training only. Eighty-six patients were enrolled. Twenty-nine patients were allocated to retromuscular polypropylene mesh and 27 to double-row plication with Quill technology. Thirty-two patients participated in a 3-month training program. Diastasis was evaluated with computed tomography scan and clinically. Pain was assessed using the ventral hernia pain questionnaire, a quality-of-life survey, SF-36, and abdominal muscle strength using the Biodex System-4. One early recurrence occurred in the Quill group, 2 encapsulated seromas in the mesh group, and 3 in the suture group. Significant improvements in perceived pain, the ventral hernia pain questionnaire, and quality of life appeared at the 1-year follow-up with no difference between the 2 operative groups. Significant muscular improvement was obtained in all groups (Biodex System-4). Patient perceived gain in muscle strength assessed with a visual analog scale improved similarly in both operative groups. This improvement was significantly greater than that seen in the training group. Patients in the training group still experienced bodily pain at follow-up. There was no difference between the Quill technique and retromuscular mesh in the effect on abdominal wall stability, with a similar complication rate 1 year after operation. An operation improves functional ability and quality of life. Training strengthens the abdominal muscles, but patients still experience discomfort and pain. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. An eFTD-VP framework for efficiently generating patient-specific anatomically detailed facial soft tissue FE mesh for craniomaxillofacial surgery simulation

    PubMed Central

    Zhang, Xiaoyan; Kim, Daeseung; Shen, Shunyao; Yuan, Peng; Liu, Siting; Tang, Zhen; Zhang, Guangming; Zhou, Xiaobo; Gateno, Jaime

    2017-01-01

    Accurate surgical planning and prediction of craniomaxillofacial surgery outcome requires simulation of soft tissue changes following osteotomy. This can only be achieved by using an anatomically detailed facial soft tissue model. The current state-of-the-art of model generation is not appropriate to clinical applications due to the time-intensive nature of manual segmentation and volumetric mesh generation. The conventional patient-specific finite element (FE) mesh generation methods are to deform a template FE mesh to match the shape of a patient based on registration. However, these methods commonly produce element distortion. Additionally, the mesh density for patients depends on that of the template model. It could not be adjusted to conduct mesh density sensitivity analysis. In this study, we propose a new framework of patient-specific facial soft tissue FE mesh generation. The goal of the developed method is to efficiently generate a high-quality patient-specific hexahedral FE mesh with adjustable mesh density while preserving the accuracy in anatomical structure correspondence. Our FE mesh is generated by eFace template deformation followed by volumetric parametrization. First, the patient-specific anatomically detailed facial soft tissue model (including skin, mucosa, and muscles) is generated by deforming an eFace template model. The adaptation of the eFace template model is achieved by using a hybrid landmark-based morphing and dense surface fitting approach followed by a thin-plate spline interpolation. Then, high-quality hexahedral mesh is constructed by using volumetric parameterization. The user can control the resolution of hexahedron mesh to best reflect clinicians’ need. Our approach was validated using 30 patient models and 4 visible human datasets. The generated patient-specific FE mesh showed high surface matching accuracy, element quality, and internal structure matching accuracy. They can be directly and effectively used for clinical simulation of facial soft tissue change. PMID:29027022

  12. An eFTD-VP framework for efficiently generating patient-specific anatomically detailed facial soft tissue FE mesh for craniomaxillofacial surgery simulation.

    PubMed

    Zhang, Xiaoyan; Kim, Daeseung; Shen, Shunyao; Yuan, Peng; Liu, Siting; Tang, Zhen; Zhang, Guangming; Zhou, Xiaobo; Gateno, Jaime; Liebschner, Michael A K; Xia, James J

    2018-04-01

    Accurate surgical planning and prediction of craniomaxillofacial surgery outcome requires simulation of soft tissue changes following osteotomy. This can only be achieved by using an anatomically detailed facial soft tissue model. The current state-of-the-art of model generation is not appropriate to clinical applications due to the time-intensive nature of manual segmentation and volumetric mesh generation. The conventional patient-specific finite element (FE) mesh generation methods are to deform a template FE mesh to match the shape of a patient based on registration. However, these methods commonly produce element distortion. Additionally, the mesh density for patients depends on that of the template model. It could not be adjusted to conduct mesh density sensitivity analysis. In this study, we propose a new framework of patient-specific facial soft tissue FE mesh generation. The goal of the developed method is to efficiently generate a high-quality patient-specific hexahedral FE mesh with adjustable mesh density while preserving the accuracy in anatomical structure correspondence. Our FE mesh is generated by eFace template deformation followed by volumetric parametrization. First, the patient-specific anatomically detailed facial soft tissue model (including skin, mucosa, and muscles) is generated by deforming an eFace template model. The adaptation of the eFace template model is achieved by using a hybrid landmark-based morphing and dense surface fitting approach followed by a thin-plate spline interpolation. Then, high-quality hexahedral mesh is constructed by using volumetric parameterization. The user can control the resolution of hexahedron mesh to best reflect clinicians' need. Our approach was validated using 30 patient models and 4 visible human datasets. The generated patient-specific FE mesh showed high surface matching accuracy, element quality, and internal structure matching accuracy. They can be directly and effectively used for clinical simulation of facial soft tissue change.

  13. Past, Present and Future of Surgical Meshes: A Review.

    PubMed

    Baylón, Karen; Rodríguez-Camarillo, Perla; Elías-Zúñiga, Alex; Díaz-Elizondo, Jose Antonio; Gilkerson, Robert; Lozano, Karen

    2017-08-22

    Surgical meshes, in particular those used to repair hernias, have been in use since 1891. Since then, research in the area has expanded, given the vast number of post-surgery complications such as infection, fibrosis, adhesions, mesh rejection, and hernia recurrence. Researchers have focused on the analysis and implementation of a wide range of materials: meshes with different fiber size and porosity, a variety of manufacturing methods, and certainly a variety of surgical and implantation procedures. Currently, surface modification methods and development of nanofiber based systems are actively being explored as areas of opportunity to retain material strength and increase biocompatibility of available meshes. This review summarizes the history of surgical meshes and presents an overview of commercial surgical meshes, their properties, manufacturing methods, and observed biological response, as well as the requirements for an ideal surgical mesh and potential manufacturing methods.

  14. Heterogeneous Wireless Mesh Network Technology Evaluation for Space Proximity and Surface Applications

    NASA Technical Reports Server (NTRS)

    DeCristofaro, Michael A.; Lansdowne, Chatwin A.; Schlesinger, Adam M.

    2014-01-01

    NASA has identified standardized wireless mesh networking as a key technology for future human and robotic space exploration. Wireless mesh networks enable rapid deployment, provide coverage in undeveloped regions. Mesh networks are also self-healing, resilient, and extensible, qualities not found in traditional infrastructure-based networks. Mesh networks can offer lower size, weight, and power (SWaP) than overlapped infrastructure-perapplication. To better understand the maturity, characteristics and capability of the technology, we developed an 802.11 mesh network consisting of a combination of heterogeneous commercial off-the-shelf devices and opensource firmware and software packages. Various streaming applications were operated over the mesh network, including voice and video, and performance measurements were made under different operating scenarios. During the testing several issues with the currently implemented mesh network technology were identified and outlined for future work.

  15. Cause and Cure - Deterioration in Accuracy of CFD Simulations with Use of High-Aspect-Ratio Triangular/Tetrahedral Grids

    NASA Technical Reports Server (NTRS)

    Chang, Sin-Chung; Chang, Chau-Lyan; Venkatachari, Balaji Shankar

    2017-01-01

    Traditionally high-aspect ratio triangular/tetrahedral meshes are avoided by CFD researchers in the vicinity of a solid wall, as it is known to reduce the accuracy of gradient computations in those regions. Although for certain complex geometries, the use of high-aspect ratio triangular/tetrahedral elements in the vicinity of a solid wall can be replaced by quadrilateral/prismatic elements, ability to use triangular/tetrahedral elements in such regions without any degradation in accuracy can be beneficial from a mesh generation point of view. The benefits also carry over to numerical frameworks such as the space-time conservation element and solution element (CESE), where simplex elements are the mandatory building blocks. With the requirement of the CESE method in mind, a rigorous mathematical framework that clearly identifies the reason behind the difficulties in use of such high-aspect ratio simplex elements is formulated using two different approaches and presented here. Drawing insights from the analysis, a potential solution to avoid that pitfall is also provided as part of this work. Furthermore, through the use of numerical simulations of practical viscous problems involving high-Reynolds number flows, how the gradient evaluation procedures of the CESE framework can be effectively used to produce accurate and stable results on such high-aspect ratio simplex meshes is also showcased.

  16. Advanced 3D mesh manipulation in stereolithographic files and post-print processing for the manufacturing of patient-specific vascular flow phantoms

    NASA Astrophysics Data System (ADS)

    O'Hara, Ryan P.; Chand, Arpita; Vidiyala, Sowmya; Arechavala, Stacie M.; Mitsouras, Dimitrios; Rudin, Stephen; Ionita, Ciprian N.

    2016-03-01

    Complex vascular anatomies can cause the failure of image-guided endovascular procedures. 3D printed patient-specific vascular phantoms provide clinicians and medical device companies the ability to preemptively plan surgical treatments, test the likelihood of device success, and determine potential operative setbacks. This research aims to present advanced mesh manipulation techniques of stereolithographic (STL) files segmented from medical imaging and post-print surface optimization to match physiological vascular flow resistance. For phantom design, we developed three mesh manipulation techniques. The first method allows outlet 3D mesh manipulations to merge superfluous vessels into a single junction, decreasing the number of flow outlets and making it feasible to include smaller vessels. Next we introduced Boolean operations to eliminate the need to manually merge mesh layers and eliminate errors of mesh self-intersections that previously occurred. Finally we optimize support addition to preserve the patient anatomical geometry. For post-print surface optimization, we investigated various solutions and methods to remove support material and smooth the inner vessel surface. Solutions of chloroform, alcohol and sodium hydroxide were used to process various phantoms and hydraulic resistance was measured and compared with values reported in literature. The newly mesh manipulation methods decrease the phantom design time by 30 - 80% and allow for rapid development of accurate vascular models. We have created 3D printed vascular models with vessel diameters less than 0.5 mm. The methods presented in this work could lead to shorter design time for patient specific phantoms and better physiological simulations.

  17. Advanced 3D Mesh Manipulation in Stereolithographic Files and Post-Print Processing for the Manufacturing of Patient-Specific Vascular Flow Phantoms.

    PubMed

    O'Hara, Ryan P; Chand, Arpita; Vidiyala, Sowmya; Arechavala, Stacie M; Mitsouras, Dimitrios; Rudin, Stephen; Ionita, Ciprian N

    2016-02-27

    Complex vascular anatomies can cause the failure of image-guided endovascular procedures. 3D printed patient-specific vascular phantoms provide clinicians and medical device companies the ability to preemptively plan surgical treatments, test the likelihood of device success, and determine potential operative setbacks. This research aims to present advanced mesh manipulation techniques of stereolithographic (STL) files segmented from medical imaging and post-print surface optimization to match physiological vascular flow resistance. For phantom design, we developed three mesh manipulation techniques. The first method allows outlet 3D mesh manipulations to merge superfluous vessels into a single junction, decreasing the number of flow outlets and making it feasible to include smaller vessels. Next we introduced Boolean operations to eliminate the need to manually merge mesh layers and eliminate errors of mesh self-intersections that previously occurred. Finally we optimize support addition to preserve the patient anatomical geometry. For post-print surface optimization, we investigated various solutions and methods to remove support material and smooth the inner vessel surface. Solutions of chloroform, alcohol and sodium hydroxide were used to process various phantoms and hydraulic resistance was measured and compared with values reported in literature. The newly mesh manipulation methods decrease the phantom design time by 30 - 80% and allow for rapid development of accurate vascular models. We have created 3D printed vascular models with vessel diameters less than 0.5 mm. The methods presented in this work could lead to shorter design time for patient specific phantoms and better physiological simulations.

  18. Advanced 3D Mesh Manipulation in Stereolithographic Files and Post-Print Processing for the Manufacturing of Patient-Specific Vascular Flow Phantoms

    PubMed Central

    O’Hara, Ryan P.; Chand, Arpita; Vidiyala, Sowmya; Arechavala, Stacie M.; Mitsouras, Dimitrios; Rudin, Stephen; Ionita, Ciprian N.

    2017-01-01

    Complex vascular anatomies can cause the failure of image-guided endovascular procedures. 3D printed patient-specific vascular phantoms provide clinicians and medical device companies the ability to preemptively plan surgical treatments, test the likelihood of device success, and determine potential operative setbacks. This research aims to present advanced mesh manipulation techniques of stereolithographic (STL) files segmented from medical imaging and post-print surface optimization to match physiological vascular flow resistance. For phantom design, we developed three mesh manipulation techniques. The first method allows outlet 3D mesh manipulations to merge superfluous vessels into a single junction, decreasing the number of flow outlets and making it feasible to include smaller vessels. Next we introduced Boolean operations to eliminate the need to manually merge mesh layers and eliminate errors of mesh self-intersections that previously occurred. Finally we optimize support addition to preserve the patient anatomical geometry. For post-print surface optimization, we investigated various solutions and methods to remove support material and smooth the inner vessel surface. Solutions of chloroform, alcohol and sodium hydroxide were used to process various phantoms and hydraulic resistance was measured and compared with values reported in literature. The newly mesh manipulation methods decrease the phantom design time by 30 – 80% and allow for rapid development of accurate vascular models. We have created 3D printed vascular models with vessel diameters less than 0.5 mm. The methods presented in this work could lead to shorter design time for patient specific phantoms and better physiological simulations. PMID:28649165

  19. Finite Macro-Element Mesh Deformation in a Structured Multi-Block Navier-Stokes Code

    NASA Technical Reports Server (NTRS)

    Bartels, Robert E.

    2005-01-01

    A mesh deformation scheme is developed for a structured multi-block Navier-Stokes code consisting of two steps. The first step is a finite element solution of either user defined or automatically generated macro-elements. Macro-elements are hexagonal finite elements created from a subset of points from the full mesh. When assembled, the finite element system spans the complete flow domain. Macro-element moduli vary according to the distance to the nearest surface, resulting in extremely stiff elements near a moving surface and very pliable elements away from boundaries. Solution of the finite element system for the imposed boundary deflections generally produces smoothly varying nodal deflections. The manner in which distance to the nearest surface has been found to critically influence the quality of the element deformation. The second step is a transfinite interpolation which distributes the macro-element nodal deflections to the remaining fluid mesh points. The scheme is demonstrated for several two-dimensional applications.

  20. The management of abdominal wall hernias – in search of consensus

    PubMed Central

    Bury, Kamil; Śmietański, Maciej

    2015-01-01

    Introduction Laparoscopic repair is becoming an increasingly popular alternative in the treatment of abdominal wall hernias. In spite of numerous studies evaluating this technique, indications for laparoscopic surgery have not been established. Similarly, implant selection and fixation techniques have not been unified and are the subject of scientific discussion. Aim To assess whether there is a consensus on the management of the most common ventral abdominal wall hernias among recognised experts. Material and methods Fourteen specialists representing the boards of European surgical societies were surveyed to determine their choice of surgical technique for nine typical primary ventral and incisional hernias. The access method, type of operation, mesh prosthesis and fixation method were evaluated. In addition to the laparoscopic procedures, the number of tackers and their arrangement were assessed. Results In none of the cases presented was a consensus of experts obtained. Laparoscopic and open techniques were used equally often. Especially in the group of large hernias, decisions on repair methods were characterised by high variability. The technique of laparoscopic mesh fixation was a subject of great variability in terms of both method selection and the numbers of tackers and sutures used. Conclusions Recognised experts have not reached a consensus on the management of abdominal wall hernias. Our survey results indicate the need for further research and the inclusion of large cohorts of patients in the dedicated registries to evaluate the results of different surgical methods, which would help in the development of treatment algorithms for surgical education in the future. PMID:25960793

  1. Strategies Toward Automation of Overset Structured Surface Grid Generation

    NASA Technical Reports Server (NTRS)

    Chan, William M.

    2017-01-01

    An outline of a strategy for automation of overset structured surface grid generation on complex geometries is described. The starting point of the process consists of an unstructured surface triangulation representation of the geometry derived from a native CAD, STEP, or IGES definition, and a set of discretized surface curves that captures all geometric features of interest. The procedure for surface grid generation is decomposed into an algebraic meshing step, a hyperbolic meshing step, and a gap-filling step. This paper will focus primarily on the high-level plan with details on the algebraic step. The algorithmic procedure for the algebraic step involves analyzing the topology of the network of surface curves, distributing grid points appropriately on these curves, identifying domains bounded by four curves that can be meshed algebraically, concatenating the resulting grids into fewer patches, and extending appropriate boundaries of the concatenated grids to provide proper overlap. Results are presented for grids created on various aerospace vehicle components.

  2. Multi-region approach to free-boundary three-dimensional tokamak equilibria and resistive wall instabilities

    NASA Astrophysics Data System (ADS)

    Ferraro, N. M.; Jardin, S. C.; Lao, L. L.; Shephard, M. S.; Zhang, F.

    2016-05-01

    Free-boundary 3D tokamak equilibria and resistive wall instabilities are calculated using a new resistive wall model in the two-fluid M3D-C1 code. In this model, the resistive wall and surrounding vacuum region are included within the computational domain. This implementation contrasts with the method typically used in fluid codes in which the resistive wall is treated as a boundary condition on the computational domain boundary and has the advantage of maintaining purely local coupling of mesh elements. This new capability is used to simulate perturbed, free-boundary non-axisymmetric equilibria; the linear evolution of resistive wall modes; and the linear and nonlinear evolution of axisymmetric vertical displacement events (VDEs). Calculated growth rates for a resistive wall mode with arbitrary wall thickness are shown to agree well with the analytic theory. Equilibrium and VDE calculations are performed in diverted tokamak geometry, at physically realistic values of dissipation, and with resistive walls of finite width. Simulations of a VDE disruption extend into the current-quench phase, in which the plasma becomes limited by the first wall, and strong currents are observed to flow in the wall, in the SOL, and from the plasma to the wall.

  3. Biocompatible Capsules and Methods of Making

    NASA Technical Reports Server (NTRS)

    Loftus, David J. (Inventor)

    2017-01-01

    Embodiments of the invention include capsules for containing medical implants and delivery systems for release of active biological substances into a host body. Delivery systems comprise a capsule comprising an interior enclosed by walls, and a source of active biological substances enclosed within the capsule interior, wherein the active biological substances are free to diffuse across the capsule walls. The capsule walls comprise a continuous mesh of biocompatible fibers and a seal region where two capsule walls overlap. The interior of the capsule is substantially isolated from the medium surrounding the capsule, except for diffusion of at least one species of molecule between the capsule interior and the ambient medium, and prevents cell migration into or out of the capsule. Methods for preparing and using the capsules and delivery systems are provided.

  4. Toward Automatic Verification of Goal-Oriented Flow Simulations

    NASA Technical Reports Server (NTRS)

    Nemec, Marian; Aftosmis, Michael J.

    2014-01-01

    We demonstrate the power of adaptive mesh refinement with adjoint-based error estimates in verification of simulations governed by the steady Euler equations. The flow equations are discretized using a finite volume scheme on a Cartesian mesh with cut cells at the wall boundaries. The discretization error in selected simulation outputs is estimated using the method of adjoint-weighted residuals. Practical aspects of the implementation are emphasized, particularly in the formulation of the refinement criterion and the mesh adaptation strategy. Following a thorough code verification example, we demonstrate simulation verification of two- and three-dimensional problems. These involve an airfoil performance database, a pressure signature of a body in supersonic flow and a launch abort with strong jet interactions. The results show reliable estimates and automatic control of discretization error in all simulations at an affordable computational cost. Moreover, the approach remains effective even when theoretical assumptions, e.g., steady-state and solution smoothness, are relaxed.

  5. The mimetic finite difference method for the Landau–Lifshitz equation

    DOE PAGES

    Kim, Eugenia Hail; Lipnikov, Konstantin Nikolayevich

    2017-01-01

    The Landau–Lifshitz equation describes the dynamics of the magnetization inside ferromagnetic materials. This equation is highly nonlinear and has a non-convex constraint (the magnitude of the magnetization is constant) which poses interesting challenges in developing numerical methods. We develop and analyze explicit and implicit mimetic finite difference schemes for this equation. These schemes work on general polytopal meshes which provide enormous flexibility to model magnetic devices with various shapes. A projection on the unit sphere is used to preserve the magnitude of the magnetization. We also provide a proof that shows the exchange energy is decreasing in certain conditions. Themore » developed schemes are tested on general meshes that include distorted and randomized meshes. As a result, the numerical experiments include a test proposed by the National Institute of Standard and Technology and a test showing formation of domain wall structures in a thin film.« less

  6. The mimetic finite difference method for the Landau–Lifshitz equation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Eugenia Hail; Lipnikov, Konstantin Nikolayevich

    The Landau–Lifshitz equation describes the dynamics of the magnetization inside ferromagnetic materials. This equation is highly nonlinear and has a non-convex constraint (the magnitude of the magnetization is constant) which poses interesting challenges in developing numerical methods. We develop and analyze explicit and implicit mimetic finite difference schemes for this equation. These schemes work on general polytopal meshes which provide enormous flexibility to model magnetic devices with various shapes. A projection on the unit sphere is used to preserve the magnitude of the magnetization. We also provide a proof that shows the exchange energy is decreasing in certain conditions. Themore » developed schemes are tested on general meshes that include distorted and randomized meshes. As a result, the numerical experiments include a test proposed by the National Institute of Standard and Technology and a test showing formation of domain wall structures in a thin film.« less

  7. Parastomal hernia – current knowledge and treatment

    PubMed Central

    Styliński, Roman; Rudzki, Sławomir

    2018-01-01

    Intestinal stoma creation is one of the most common surgical procedures. The most common long-term complication following stoma creation is parastomal hernia, which according to some authors is practically unavoidable. Statistical differences of its occurrence are mainly due to patient observation time and evaluation criteria. Consequently, primary prevention methods such as placement of prosthetic mesh and newly developed minimally invasive methods of stoma creation are used. It seems that in the light of evidence-based medicine, the best way to treat parastomal hernia is the one that the surgeon undertaking therapy is the most experienced in and is suited to the individuality of each patient, his condition and comorbidities. As a general rule, reinforcing the abdominal wall with a prosthetic mesh is the treatment of choice, with a low rate of complications and relapses over a long period of time. The current trend is to use lightweight, large pore meshes. PMID:29643952

  8. Past, Present and Future of Surgical Meshes: A Review

    PubMed Central

    Baylón, Karen; Rodríguez-Camarillo, Perla; Elías-Zúñiga, Alex; Díaz-Elizondo, Jose Antonio; Gilkerson, Robert; Lozano, Karen

    2017-01-01

    Surgical meshes, in particular those used to repair hernias, have been in use since 1891. Since then, research in the area has expanded, given the vast number of post-surgery complications such as infection, fibrosis, adhesions, mesh rejection, and hernia recurrence. Researchers have focused on the analysis and implementation of a wide range of materials: meshes with different fiber size and porosity, a variety of manufacturing methods, and certainly a variety of surgical and implantation procedures. Currently, surface modification methods and development of nanofiber based systems are actively being explored as areas of opportunity to retain material strength and increase biocompatibility of available meshes. This review summarizes the history of surgical meshes and presents an overview of commercial surgical meshes, their properties, manufacturing methods, and observed biological response, as well as the requirements for an ideal surgical mesh and potential manufacturing methods. PMID:28829367

  9. Pyrolysis-catalysis of waste plastic using a nickel-stainless-steel mesh catalyst for high-value carbon products.

    PubMed

    Zhang, Yeshui; Nahil, Mohamad A; Wu, Chunfei; Williams, Paul T

    2017-11-01

    A stainless-steel mesh loaded with nickel catalyst was produced and used for the pyrolysis-catalysis of waste high-density polyethylene with the aim of producing high-value carbon products, including carbon nanotubes (CNTs). The catalysis temperature and plastic-to-catalyst ratio were investigated to determine the influence on the formation of different types of carbon deposited on the nickel-stainless-steel mesh catalyst. Increasing temperature from 700 to 900°C resulted in an increase in the carbon deposited on the nickel-loaded stainless-steel mesh catalyst from 32.5 to 38.0 wt%. The increase in sample-to-catalyst ratio reduced the amount of carbon deposited on the mesh catalyst in terms of g carbon g -1 plastic. The carbons were found to be largely composed of filamentous carbons, with negligible disordered (amorphous) carbons. Transmission electron microscopy analysis of the filamentous carbons revealed them to be composed of a large proportion (estimated at ∼40%) multi-walled carbon nanotubes (MWCNTs). The optimum process conditions for CNT production, in terms of yield and graphitic nature, determined by Raman spectroscopy, was catalysis temperature of 800°C and plastic-to-catalyst ratio of 1:2, where a mass of 334 mg of filamentous/MWCNTs g -1 plastic was produced.

  10. Towards hybrid mesh generation for realistic design environments

    NASA Astrophysics Data System (ADS)

    McMorris, Harlan Tom

    Two different techniques that allow hybrid mesh generation to be easily used in the design environment are presented. The purpose of this research is to allow for hybrid meshes to be used during the design process where the geometry is being varied. The first technique, modular hybrid mesh generation, allows for the replacement of portions of a geometry with a new design shape. The mesh is maintained for the portions of that have not changed during the design process. A new mesh is generated for the new part of the geometry and this piece is added to the existing mesh. The new mesh must match the remaining portions of the geometry plus the element sizes must match exactly across the interfaces. The second technique, hybrid mesh movement, is used when the basic geometry remains the same with only small variations to portions of the geometry. These small variations include changing the cross-section of a wing, twisting a blade or changing the length of some portion of the geometry. The mesh for the original geometry is moved onto the new geometry one step at a time beginning with the curves of the surface, continuing with the surface mesh geometry and ending with the interior points of the mesh. The validity of the hybrid mesh is maintained by applying corrections to the motion of the points. Finally, the quality of the new hybrid mesh is improved to ensure that the new mesh maintains the quality of the original hybrid mesh. Applications of both design techniques are applied to typical example cases from the fields of turbomachinery, aerospace and offshore technology. The example test cases demonstrate the ability of the two techniques to reuse the majority of an existing hybrid mesh for typical design changes. Modular mesh generation is used to change the shape of piece of a seafloor pipeline geometry to a completely different configuration. The hybrid mesh movement technique is used to change the twist of a turbomachinery blade, the tip clearance of a rotor blade and to simulate the aeroelastic bending of a wing. Finally, the movement technique is applied to an offshore application where the solution for the original configuration is used as a starting point for solution for a new configuration. The application of both techniques show that the methods can be a powerful addition to the design environment and will facilitate a rapid turnaround when the design geometry changes.

  11. A computational method for sharp interface advection.

    PubMed

    Roenby, Johan; Bredmose, Henrik; Jasak, Hrvoje

    2016-11-01

    We devise a numerical method for passive advection of a surface, such as the interface between two incompressible fluids, across a computational mesh. The method is called isoAdvector, and is developed for general meshes consisting of arbitrary polyhedral cells. The algorithm is based on the volume of fluid (VOF) idea of calculating the volume of one of the fluids transported across the mesh faces during a time step. The novelty of the isoAdvector concept consists of two parts. First, we exploit an isosurface concept for modelling the interface inside cells in a geometric surface reconstruction step. Second, from the reconstructed surface, we model the motion of the face-interface intersection line for a general polygonal face to obtain the time evolution within a time step of the submerged face area. Integrating this submerged area over the time step leads to an accurate estimate for the total volume of fluid transported across the face. The method was tested on simple two-dimensional and three-dimensional interface advection problems on both structured and unstructured meshes. The results are very satisfactory in terms of volume conservation, boundedness, surface sharpness and efficiency. The isoAdvector method was implemented as an OpenFOAM ® extension and is published as open source.

  12. A computational method for the coupled solution of reaction-diffusion equations on evolving domains and manifolds: Application to a model of cell migration and chemotaxis.

    PubMed

    MacDonald, G; Mackenzie, J A; Nolan, M; Insall, R H

    2016-03-15

    In this paper, we devise a moving mesh finite element method for the approximate solution of coupled bulk-surface reaction-diffusion equations on an evolving two dimensional domain. Fundamental to the success of the method is the robust generation of bulk and surface meshes. For this purpose, we use a novel moving mesh partial differential equation (MMPDE) approach. The developed method is applied to model problems with known analytical solutions; these experiments indicate second-order spatial and temporal accuracy. Coupled bulk-surface problems occur frequently in many areas; in particular, in the modelling of eukaryotic cell migration and chemotaxis. We apply the method to a model of the two-way interaction of a migrating cell in a chemotactic field, where the bulk region corresponds to the extracellular region and the surface to the cell membrane.

  13. Generation of a crowned pinion tooth surface by a surface of revolution

    NASA Technical Reports Server (NTRS)

    Litvin, F. L.; Zhang, J.; Handschuh, R. F.

    1988-01-01

    A method of generating crowned pinion tooth surfaces using a surface of revolution is developed. The crowned pinion meshes with a regular involute gear and has a prescribed parabolic type of transmission errors when the gears operate in the aligned mode. When the gears are misaligned the transmission error remains parabolic with the maximum level still remaining very small (less than 0.34 arc sec for the numerical examples). Tooth contact analysis (TCA) is used to simulate the conditions of meshing, determine the transmission error, and determine the bearing contact.

  14. Path Planning Based on Ply Orientation Information for Automatic Fiber Placement on Mesh Surface

    NASA Astrophysics Data System (ADS)

    Pei, Jiazhi; Wang, Xiaoping; Pei, Jingyu; Yang, Yang

    2018-03-01

    This article introduces an investigation of path planning with ply orientation information for automatic fiber placement (AFP) on open-contoured mesh surface. The new method makes use of the ply orientation information generated by loading characteristics on surface, divides the surface into several zones according to the ply orientation information and then designs different fiber paths in different zones. This article also gives new idea of up-layer design in order to make up for defects between parts and improve product's strength.

  15. SU-F-BRF-09: A Non-Rigid Point Matching Method for Accurate Bladder Dose Summation in Cervical Cancer HDR Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, H; Zhen, X; Zhou, L

    2014-06-15

    Purpose: To propose and validate a deformable point matching scheme for surface deformation to facilitate accurate bladder dose summation for fractionated HDR cervical cancer treatment. Method: A deformable point matching scheme based on the thin plate spline robust point matching (TPSRPM) algorithm is proposed for bladder surface registration. The surface of bladders segmented from fractional CT images is extracted and discretized with triangular surface mesh. Deformation between the two bladder surfaces are obtained by matching the two meshes' vertices via the TPS-RPM algorithm, and the deformation vector fields (DVFs) characteristic of this deformation is estimated by B-spline approximation. Numerically, themore » algorithm is quantitatively compared with the Demons algorithm using five clinical cervical cancer cases by several metrics: vertex-to-vertex distance (VVD), Hausdorff distance (HD), percent error (PE), and conformity index (CI). Experimentally, the algorithm is validated on a balloon phantom with 12 surface fiducial markers. The balloon is inflated with different amount of water, and the displacement of fiducial markers is benchmarked as ground truth to study TPS-RPM calculated DVFs' accuracy. Results: In numerical evaluation, the mean VVD is 3.7(±2.0) mm after Demons, and 1.3(±0.9) mm after TPS-RPM. The mean HD is 14.4 mm after Demons, and 5.3mm after TPS-RPM. The mean PE is 101.7% after Demons and decreases to 18.7% after TPS-RPM. The mean CI is 0.63 after Demons, and increases to 0.90 after TPS-RPM. In the phantom study, the mean Euclidean distance of the fiducials is 7.4±3.0mm and 4.2±1.8mm after Demons and TPS-RPM, respectively. Conclusions: The bladder wall deformation is more accurate using the feature-based TPS-RPM algorithm than the intensity-based Demons algorithm, indicating that TPS-RPM has the potential for accurate bladder dose deformation and dose summation for multi-fractional cervical HDR brachytherapy. This work is supported in part by the National Natural ScienceFoundation of China (no 30970866 and no 81301940)« less

  16. Simulating Soft Shadows with Graphics Hardware,

    DTIC Science & Technology

    1997-01-15

    This radiance texture is analogous to the mesh of radiosity values computed in a radiosity algorithm. Unlike a radiosity algorithm, however, our...discretely. Several researchers have explored continuous visibility methods for soft shadow computation and radiosity mesh generation. With this approach...times of several seconds [9]. Most radiosity methods discretize each surface into a mesh of elements and then use discrete methods such as ray

  17. The functional response of bioactive titania-modified three-dimensional Ti-6Al-4V mesh structure toward providing a favorable pathway for intercellular communication and osteoincorporation.

    PubMed

    Nune, K C; Misra, R D K; Li, S J; Hao, Y L; Zhang, W

    2016-10-01

    The objective of the study is to fundamentally elucidate the biological response of 3D printed mesh structures subjected to plasma electrolytic oxidation process through the study of osteoblast functions. The cellular activity of plasma electrolytic-oxidized mesh structure was explored in terms of cell-to-cell communication involving proliferation, synthesis of extracellular and intracellular proteins, and mineralization. Upon plasma electrolytic oxidation of the mesh structure, a thin layer of bioactive titania with pore size 1-3 µm was nucleated on the surface. The combination of microporous bioactive titania and interconnected porous architecture provided the desired pathway for supply of nutrients and oxygen to cells and tissue and a favorable osteogenic microenvironment for tissue on-growth and in-growth, in relation to the unmodified mesh structure. The formation of a confluent layer as envisaged via electron microscopy and quantitative assessment of the expression level of proteins (actin, vinculin, and fibronectin) point toward the determining role of surface-modified mesh structure in modulating osteoblasts functions. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 2488-2501, 2016. © 2016 Wiley Periodicals, Inc.

  18. Effects of bedding material and running wheel surface on paw wounds in male and female Syrian hamsters.

    PubMed

    Beaulieu, A; Reebs, S G

    2009-01-01

    The present study investigated the effects of bedding material (pine shavings versus beta chip) and running wheel surfaces (standard metal bars versus metal bars covered with a plastic mesh) on the occurrence of wounds on the paws of male and female Syrian (golden) hamsters, Mesocricetus auratus. Four groups of 10 males and 10 females were each assigned to one of the following treatments: pine/no mesh, pine/mesh, chips/no mesh and chips/mesh. Each hamster paw was observed at 1-3-day intervals for 60 days. A total of 1-3 wounds, separate in time, developed on the paws (mostly the hind ones) of almost all animals. Wounds appeared as small pinpricks, cuts or scabs, mostly on the palms. Females ran 15% less than males, yet their front paws were more commonly affected and their wounds tended to last longer. Hamsters with plastic mesh inside their wheels took longer to develop wounds but once they appeared, the wounds were larger and lasted longer. Hamsters on pine shavings developed fewer wounds and had more wound-free days. Hamsters kept running at high levels and many wounds did not heal during the study, suggesting a need for veterinary intervention.

  19. Discrete Data Transfer Technique for Fluid-Structure Interaction

    NASA Technical Reports Server (NTRS)

    Samareh, Jamshid A.

    2007-01-01

    This paper presents a general three-dimensional algorithm for data transfer between dissimilar meshes. The algorithm is suitable for applications of fluid-structure interaction and other high-fidelity multidisciplinary analysis and optimization. Because the algorithm is independent of the mesh topology, we can treat structured and unstructured meshes in the same manner. The algorithm is fast and accurate for transfer of scalar or vector fields between dissimilar surface meshes. The algorithm is also applicable for the integration of a scalar field (e.g., coefficients of pressure) on one mesh and injection of the resulting vectors (e.g., force vectors) onto another mesh. The author has implemented the algorithm in a C++ computer code. This paper contains a complete formulation of the algorithm with a few selected results.

  20. Calculation of grain boundary normals directly from 3D microstructure images

    DOE PAGES

    Lieberman, E. J.; Rollett, A. D.; Lebensohn, R. A.; ...

    2015-03-11

    The determination of grain boundary normals is an integral part of the characterization of grain boundaries in polycrystalline materials. These normal vectors are difficult to quantify due to the discretized nature of available microstructure characterization techniques. The most common method to determine grain boundary normals is by generating a surface mesh from an image of the microstructure, but this process can be slow, and is subject to smoothing issues. A new technique is proposed, utilizing first order Cartesian moments of binary indicator functions, to determine grain boundary normals directly from a voxelized microstructure image. In order to validate the accuracymore » of this technique, the surface normals obtained by the proposed method are compared to those generated by a surface meshing algorithm. Specifically, the local divergence between the surface normals obtained by different variants of the proposed technique and those generated from a surface mesh of a synthetic microstructure constructed using a marching cubes algorithm followed by Laplacian smoothing is quantified. Next, surface normals obtained with the proposed method from a measured 3D microstructure image of a Ni polycrystal are used to generate grain boundary character distributions (GBCD) for Σ3 and Σ9 boundaries, and compared to the GBCD generated using a surface mesh obtained from the same image. Finally, the results show that the proposed technique is an efficient and accurate method to determine voxelized fields of grain boundary normals.« less

  1. Financial implications of ventral hernia repair: a hospital cost analysis.

    PubMed

    Reynolds, Drew; Davenport, Daniel L; Korosec, Ryan L; Roth, J Scott

    2013-01-01

    Complicated ventral hernias are often referred to tertiary care centers. Hospital costs associated with these repairs include direct costs (mesh materials, supplies, and nonsurgeon labor costs) and indirect costs (facility fees, equipment depreciation, and unallocated labor). Operative supplies represent a significant component of direct costs, especially in an era of proprietary synthetic meshes and biologic grafts. We aim to evaluate the cost-effectiveness of complex abdominal wall hernia repair at a tertiary care referral facility. Cost data on all consecutive open ventral hernia repairs (CPT codes 49560, 49561, 49565, and 49566) performed between 1 July 2008 and 31 May 2011 were analyzed. Cases were analyzed based upon hospital status (inpatient vs. outpatient) and whether the hernia repair was a primary or secondary procedure. We examined median net revenue, direct costs, contribution margin, indirect costs, and net profit/loss. Among primary hernia repairs, cost data were further analyzed based upon mesh utilization (no mesh, synthetic, or biologic). Four-hundred and fifteen patients underwent ventral hernia repair (353 inpatients and 62 outpatients); 173 inpatients underwent ventral hernia repair as the primary procedure; 180 inpatients underwent hernia repair as a secondary procedure. Median net revenue ($17,310 vs. 10,360, p < 0.001) and net losses (3,430 vs. 1,700, p < 0.025) were significantly greater for those who underwent hernia repair as a secondary procedure. Among inpatients undergoing ventral hernia repair as the primary procedure, 46 were repaired without mesh; 79 were repaired with synthetic mesh and 48 with biologic mesh. Median direct costs for cases performed without mesh were $5,432; median direct costs for those using synthetic and biologic mesh were $7,590 and 16,970, respectively (p < .01). Median net losses for repairs without mesh were $500. Median net profit of $60 was observed for synthetic mesh-based repairs. The median contribution margin for cases utilizing biologic mesh was -$4,560, and the median net financial loss was $8,370. Outpatient ventral hernia repairs, with and without synthetic mesh, resulted in median net losses of $1,560 and 230, respectively. Ventral hernia repair is associated with overall financial losses. Inpatient synthetic mesh repairs are essentially budget neutral. Outpatient and inpatient repairs without mesh result in net financial losses. Inpatient biologic mesh repairs result in a negative contribution margin and striking net financial losses. Cost-effective strategies for managing ventral hernias in a tertiary care environment need to be developed in light of the financial implications of this patient population.

  2. Numerical investigation of hyperelastic wall deformation characteristics in a micro-scale stenotic blood vessel

    NASA Astrophysics Data System (ADS)

    Cheema, Taqi Ahmad; Park, Cheol Woo

    2013-08-01

    Stenosis is the drastic reduction of blood vessel diameter because of cholesterol accumulation in the vessel wall. In addition to the changes in blood flow characteristics, significant changes occur in the mechanical behavior of a stenotic blood vessel. We conducted a 3-D study of such behavior in micro-scale blood vessels by considering the fluid structure interaction between blood flow and vessel wall structure. The simulation consisted of one-way coupled analysis of blood flow and the resulting structural deformation without a moving mesh. A commercial code based on a finite element method with a hyperelastic material model (Neo-Hookean) of the wall was used to calculate wall deformation. Three different cases of stenosis severity and aspect ratios with and without muscles around the blood vessel were considered. The results showed that the wall deformation in a stenotic channel is directly related to stenosis severity and aspect ratio. The presence of muscles reduces the degree of deformation even in very severe stenosis.

  3. SutraGUI, a graphical-user interface for SUTRA, a model for ground-water flow with solute or energy transport

    USGS Publications Warehouse

    Winston, Richard B.; Voss, Clifford I.

    2004-01-01

    This report describes SutraGUI, a flexible graphical user-interface (GUI) that supports two-dimensional (2D) and three-dimensional (3D) simulation with the U.S. Geological Survey (USGS) SUTRA ground-water-flow and transport model (Voss and Provost, 2002). SutraGUI allows the user to create SUTRA ground-water models graphically. SutraGUI provides all of the graphical functionality required for setting up and running SUTRA simulations that range from basic to sophisticated, but it is also possible for advanced users to apply programmable features within Argus ONE to meet the unique demands of particular ground-water modeling projects. SutraGUI is a public-domain computer program designed to run with the proprietary Argus ONE? package, which provides 2D Geographic Information System (GIS) and meshing support. For 3D simulation, GIS and meshing support is provided by programming contained within SutraGUI. When preparing a 3D SUTRA model, the model and all of its features are viewed within Argus 1 in 2D projection. For 2D models, SutraGUI is only slightly changed in functionality from the previous 2D-only version (Voss and others, 1997) and it provides visualization of simulation results. In 3D, only model preparation is supported by SutraGUI, and 3D simulation results may be viewed in SutraPlot (Souza, 1999) or Model Viewer (Hsieh and Winston, 2002). A comprehensive online Help system is included in SutraGUI. For 3D SUTRA models, the 3D model domain is conceptualized as bounded on the top and bottom by 2D surfaces. The 3D domain may also contain internal surfaces extending across the model that divide the domain into tabular units, which can represent hydrogeologic strata or other features intended by the user. These surfaces can be non-planar and non-horizontal. The 3D mesh is defined by one or more 2D meshes at different elevations that coincide with these surfaces. If the nodes in the 3D mesh are vertically aligned, only a single 2D mesh is needed. For nonaligned meshes, two or more 2D meshes of similar connectivity are used. Between each set of 2D meshes (and model surfaces), the vertical space in the 3D mesh is evenly divided into a user-specified number of layers of finite elements. Boundary conditions may be specified for 3D models in SutraGUI using a variety of geometric shapes that may be located freely within the 3D model domain. These shapes include points, lines, sheets, and solids. These are represented by 2D contours (within the vertically-projected Argus ONE view) with user-defined elevations. In addition, boundary conditions may be specified for 3D models as points, lines, and areas that are located exactly within the surfaces that define the model top and the bottoms of the tabular units. Aquifer properties may be specified separately for each tabular unit. If the aquifer properties vary vertically within a unit, SutraGUI provides the Sutra_Z function that can be used to specify such variation.

  4. Worm Gear With Hydrostatic Engagement

    NASA Technical Reports Server (NTRS)

    Chaiko, Lev I.

    1994-01-01

    In proposed worm-gear transmission, oil pumped at high pressure through meshes between teeth of gear and worm coil. Pressure in oil separates meshing surfaces slightly, and oil reduces friction between surfaces. Conceived for use in drive train between gas-turbine engine and rotor of helicopter. Useful in other applications in which weight critical. Test apparatus simulates and measures some loading conditions of proposed worm gear with hydrostatic engagement.

  5. Performance Evaluation of Various STL File Mesh Refining Algorithms Applied for FDM-RP Process

    NASA Astrophysics Data System (ADS)

    Ledalla, Siva Rama Krishna; Tirupathi, Balaji; Sriram, Venkatesh

    2018-06-01

    Layered manufacturing machines use the stereolithography (STL) file to build parts. When a curved surface is converted from a computer aided design (CAD) file to STL, it results in a geometrical distortion and chordal error. Parts manufactured with this file, might not satisfy geometric dimensioning and tolerance requirements due to approximated geometry. Current algorithms built in CAD packages have export options to globally reduce this distortion, which leads to an increase in the file size and pre-processing time. In this work, different mesh subdivision algorithms are applied on STL file of a complex geometric features using MeshLab software. The mesh subdivision algorithms considered in this work are modified butterfly subdivision technique, loops sub division technique and general triangular midpoint sub division technique. A comparative study is made with respect to volume and the build time using the above techniques. It is found that triangular midpoint sub division algorithm is more suitable for the geometry under consideration. Only the wheel cap part is then manufactured on Stratasys MOJO FDM machine. The surface roughness of the part is measured on Talysurf surface roughness tester.

  6. Cu mesh's super-hydrophobic and oleophobic properties with variations in gravitational pressure and surface components for oil/water separation applications

    NASA Astrophysics Data System (ADS)

    Guo, Wei; Zhang, Qin; Xiao, Haibo; Xu, Jie; Li, Qintao; Pan, Xiaohui; Huang, Zhiyong

    2014-09-01

    The super-hydrophobic and super-oleophilic properties of various materials have been utilized to separate oil from water. These properties induce both oil penetration and water slide off. This research demonstrates that the mesh with both super-hydrophobic and oleophobic properties, with a water contact angle (WCA) higher than 150° and oil contact angle (OCA) near 140°, can also be used to separate oil from. Oil has a higher probability than water of entering into the interstice of the Cu mesh surface and passing through it due to the capillarity effect, van der Waals attractions and the effects of gravitational pressure. The modified mesh surface can easily adsorb the oil, which then forms a film, due to the very strong adhesion properties of the oil molecules. The oil film then contributes to the water sliding off. These properties can be used to separate oil from water with separation efficiencies reaching 99.3%. Additionally, the separation of an oil/water mixture using sand permeated with oil yielded separation efficiencies exceeding 90%.

  7. Application of Parallel Adjoint-Based Error Estimation and Anisotropic Grid Adaptation for Three-Dimensional Aerospace Configurations

    NASA Technical Reports Server (NTRS)

    Lee-Rausch, E. M.; Park, M. A.; Jones, W. T.; Hammond, D. P.; Nielsen, E. J.

    2005-01-01

    This paper demonstrates the extension of error estimation and adaptation methods to parallel computations enabling larger, more realistic aerospace applications and the quantification of discretization errors for complex 3-D solutions. Results were shown for an inviscid sonic-boom prediction about a double-cone configuration and a wing/body segmented leading edge (SLE) configuration where the output function of the adjoint was pressure integrated over a part of the cylinder in the near field. After multiple cycles of error estimation and surface/field adaptation, a significant improvement in the inviscid solution for the sonic boom signature of the double cone was observed. Although the double-cone adaptation was initiated from a very coarse mesh, the near-field pressure signature from the final adapted mesh compared very well with the wind-tunnel data which illustrates that the adjoint-based error estimation and adaptation process requires no a priori refinement of the mesh. Similarly, the near-field pressure signature for the SLE wing/body sonic boom configuration showed a significant improvement from the initial coarse mesh to the final adapted mesh in comparison with the wind tunnel results. Error estimation and field adaptation results were also presented for the viscous transonic drag prediction of the DLR-F6 wing/body configuration, and results were compared to a series of globally refined meshes. Two of these globally refined meshes were used as a starting point for the error estimation and field-adaptation process where the output function for the adjoint was the total drag. The field-adapted results showed an improvement in the prediction of the drag in comparison with the finest globally refined mesh and a reduction in the estimate of the remaining drag error. The adjoint-based adaptation parameter showed a need for increased resolution in the surface of the wing/body as well as a need for wake resolution downstream of the fuselage and wing trailing edge in order to achieve the requested drag tolerance. Although further adaptation was required to meet the requested tolerance, no further cycles were computed in order to avoid large discrepancies between the surface mesh spacing and the refined field spacing.

  8. One-step fabrication of robust superhydrophobic and superoleophilic surfaces with self-cleaning and oil/water separation function.

    PubMed

    Zhang, Zhi-Hui; Wang, Hu-Jun; Liang, Yun-Hong; Li, Xiu-Juan; Ren, Lu-Quan; Cui, Zhen-Quan; Luo, Cheng

    2018-03-01

    Superhydrophobic surfaces have great potential for application in self-cleaning and oil/water separation. However, the large-scale practical applications of superhydrophobic coating surfaces are impeded by many factors, such as complicated fabrication processes, the use of fluorinated reagents and noxious organic solvents and poor mechanical stability. Herein, we describe the successful preparation of a fluorine-free multifunctional coating without noxious organic solvents that was brushed, dipped or sprayed onto glass slides and stainless-steel meshes as substrates. The obtained multifunctional superhydrophobic and superoleophilic surfaces (MSHOs) demonstrated self-cleaning abilities even when contaminated with or immersed in oil. The superhydrophobic surfaces were robust and maintained their water repellency after being scratched with a knife or abraded with sandpaper for 50 cycles. In addition, stainless-steel meshes sprayed with the coating quickly separated various oil/water mixtures with a high separation efficiency (>93%). Furthermore, the coated mesh maintained a high separation efficiency above 95% over 20 cycles of separation. This simple and effective strategy will inspire the large-scale fabrication of multifunctional surfaces for practical applications in self-cleaning and oil/water separation.

  9. Implicit mesh discontinuous Galerkin methods and interfacial gauge methods for high-order accurate interface dynamics, with applications to surface tension dynamics, rigid body fluid-structure interaction, and free surface flow: Part I

    NASA Astrophysics Data System (ADS)

    Saye, Robert

    2017-09-01

    In this two-part paper, a high-order accurate implicit mesh discontinuous Galerkin (dG) framework is developed for fluid interface dynamics, facilitating precise computation of interfacial fluid flow in evolving geometries. The framework uses implicitly defined meshes-wherein a reference quadtree or octree grid is combined with an implicit representation of evolving interfaces and moving domain boundaries-and allows physically prescribed interfacial jump conditions to be imposed or captured with high-order accuracy. Part one discusses the design of the framework, including: (i) high-order quadrature for implicitly defined elements and faces; (ii) high-order accurate discretisation of scalar and vector-valued elliptic partial differential equations with interfacial jumps in ellipticity coefficient, leading to optimal-order accuracy in the maximum norm and discrete linear systems that are symmetric positive (semi)definite; (iii) the design of incompressible fluid flow projection operators, which except for the influence of small penalty parameters, are discretely idempotent; and (iv) the design of geometric multigrid methods for elliptic interface problems on implicitly defined meshes and their use as preconditioners for the conjugate gradient method. Also discussed is a variety of aspects relating to moving interfaces, including: (v) dG discretisations of the level set method on implicitly defined meshes; (vi) transferring state between evolving implicit meshes; (vii) preserving mesh topology to accurately compute temporal derivatives; (viii) high-order accurate reinitialisation of level set functions; and (ix) the integration of adaptive mesh refinement. In part two, several applications of the implicit mesh dG framework in two and three dimensions are presented, including examples of single phase flow in nontrivial geometry, surface tension-driven two phase flow with phase-dependent fluid density and viscosity, rigid body fluid-structure interaction, and free surface flow. A class of techniques known as interfacial gauge methods is adopted to solve the corresponding incompressible Navier-Stokes equations, which, compared to archetypical projection methods, have a weaker coupling between fluid velocity, pressure, and interface position, and allow high-order accurate numerical methods to be developed more easily. Convergence analyses conducted throughout the work demonstrate high-order accuracy in the maximum norm for all of the applications considered; for example, fourth-order spatial accuracy in fluid velocity, pressure, and interface location is demonstrated for surface tension-driven two phase flow in 2D and 3D. Specific application examples include: vortex shedding in nontrivial geometry, capillary wave dynamics revealing fine-scale flow features, falling rigid bodies tumbling in unsteady flow, and free surface flow over a submersed obstacle, as well as high Reynolds number soap bubble oscillation dynamics and vortex shedding induced by a type of Plateau-Rayleigh instability in water ripple free surface flow. These last two examples compare numerical results with experimental data and serve as an additional means of validation; they also reveal physical phenomena not visible in the experiments, highlight how small-scale interfacial features develop and affect macroscopic dynamics, and demonstrate the wide range of spatial scales often at play in interfacial fluid flow.

  10. Implicit mesh discontinuous Galerkin methods and interfacial gauge methods for high-order accurate interface dynamics, with applications to surface tension dynamics, rigid body fluid-structure interaction, and free surface flow: Part II

    NASA Astrophysics Data System (ADS)

    Saye, Robert

    2017-09-01

    In this two-part paper, a high-order accurate implicit mesh discontinuous Galerkin (dG) framework is developed for fluid interface dynamics, facilitating precise computation of interfacial fluid flow in evolving geometries. The framework uses implicitly defined meshes-wherein a reference quadtree or octree grid is combined with an implicit representation of evolving interfaces and moving domain boundaries-and allows physically prescribed interfacial jump conditions to be imposed or captured with high-order accuracy. Part one discusses the design of the framework, including: (i) high-order quadrature for implicitly defined elements and faces; (ii) high-order accurate discretisation of scalar and vector-valued elliptic partial differential equations with interfacial jumps in ellipticity coefficient, leading to optimal-order accuracy in the maximum norm and discrete linear systems that are symmetric positive (semi)definite; (iii) the design of incompressible fluid flow projection operators, which except for the influence of small penalty parameters, are discretely idempotent; and (iv) the design of geometric multigrid methods for elliptic interface problems on implicitly defined meshes and their use as preconditioners for the conjugate gradient method. Also discussed is a variety of aspects relating to moving interfaces, including: (v) dG discretisations of the level set method on implicitly defined meshes; (vi) transferring state between evolving implicit meshes; (vii) preserving mesh topology to accurately compute temporal derivatives; (viii) high-order accurate reinitialisation of level set functions; and (ix) the integration of adaptive mesh refinement. In part two, several applications of the implicit mesh dG framework in two and three dimensions are presented, including examples of single phase flow in nontrivial geometry, surface tension-driven two phase flow with phase-dependent fluid density and viscosity, rigid body fluid-structure interaction, and free surface flow. A class of techniques known as interfacial gauge methods is adopted to solve the corresponding incompressible Navier-Stokes equations, which, compared to archetypical projection methods, have a weaker coupling between fluid velocity, pressure, and interface position, and allow high-order accurate numerical methods to be developed more easily. Convergence analyses conducted throughout the work demonstrate high-order accuracy in the maximum norm for all of the applications considered; for example, fourth-order spatial accuracy in fluid velocity, pressure, and interface location is demonstrated for surface tension-driven two phase flow in 2D and 3D. Specific application examples include: vortex shedding in nontrivial geometry, capillary wave dynamics revealing fine-scale flow features, falling rigid bodies tumbling in unsteady flow, and free surface flow over a submersed obstacle, as well as high Reynolds number soap bubble oscillation dynamics and vortex shedding induced by a type of Plateau-Rayleigh instability in water ripple free surface flow. These last two examples compare numerical results with experimental data and serve as an additional means of validation; they also reveal physical phenomena not visible in the experiments, highlight how small-scale interfacial features develop and affect macroscopic dynamics, and demonstrate the wide range of spatial scales often at play in interfacial fluid flow.

  11. Optimal Inlet Shape Design of N2B Hybrid Wing Body Configuration

    NASA Technical Reports Server (NTRS)

    Kim, Hyoungjin; Liou, Meng-Sing

    2012-01-01

    The N2B hybrid wing body aircraft was conceptually designed to meet environmental and performance goals for the N+2 generation transport set by the Subsonic Fixed Wing project of NASA Fundamental Aeronautics Program. In the present study, flow simulations are conducted around the N2B configuration by a Reynolds-averaged Navier-Stokes flow solver using unstructured meshes. Boundary conditions at engine fan face and nozzle exhaust planes are provided by the NPSS thermodynamic engine cycle model. The flow simulations reveal challenging design issues arising from boundary layer ingestion offset inlet and airframe-propulsion integration. Adjoint-based optimal designs are then conducted for the inlet shape to minimize the airframe drag force and flow distortion at fan faces. Design surfaces are parameterized by NURBS, and the cowl lip geometry is modified by a spring analogy approach. By the drag minimization design, flow separation on the cowl surfaces are almost removed, and shock wave strength got remarkably reduced. For the distortion minimization design, a circumferential distortion indicator DPCP(sub avg) is adopted as the design objective and diffuser bottom and side wall surfaces are perturbed for the design. The distortion minimization results in a 12.5 % reduction in the objective function.

  12. On the Use of CAD-Native Predicates and Geometry in Surface Meshing

    NASA Technical Reports Server (NTRS)

    Aftosmis, M. J.

    1999-01-01

    Several paradigms for accessing CAD geometry during surface meshing for CFD are discussed. File translation, inconsistent geometry engines and non-native point construction are all identified as sources of non-robustness. The paper argues in favor of accessing CAD parts and assemblies in their native format, without translation, and for the use of CAD-native predicates and constructors in surface mesh generation. The discussion also emphasizes the importance of examining the computational requirements for exact evaluation of triangulation predicates during surface meshing. The native approach is demonstrated through an algorithm for the generation of closed manifold surface triangulations from CAD geometry. CAD parts and assemblies are used in their native format, and a part's native geometry engine is accessed through a modeler-independent application programming interface (API). In seeking a robust and fully automated procedure, the algorithm is based on a new physical space manifold triangulation technique specially developed to avoid robustness issues associated with poorly conditioned mappings. In addition, this approach avoids the usual ambiguities associated with floating-point predicate evaluation on constructed coordinate geometry in a mapped space. The technique is incremental, so that each new site improves the triangulation by some well defined quality measure. The algorithm terminates after achieving a prespecified measure of mesh quality and produces a triangulation such that no angle is less than a given angle bound, a or greater than pi - 2alpha. This result also sets bounds on the maximum vertex degree, triangle aspect-ratio and maximum stretching rate for the triangulation. In addition to the output triangulations for a variety of CAD parts, the discussion presents related theoretical results which assert the existence of such an angle bound, and demonstrate that maximum bounds of between 25 deg and 30 deg may be achieved in practice.

  13. Multi-region approach to free-boundary three-dimensional tokamak equilibria and resistive wall instabilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferraro, N. M.; Jardin, S. C.; Lao, L. L.

    Free-boundary 3D tokamak equilibria and resistive wall instabilities are calculated using a new resistive wall model in the two-fluid M3D-C1 code. In this model, the resistive wall and surround- ing vacuum region are included within the computational domain. Our implementation contrasts with the method typically used in fluid codes in which the resistive wall is treated as a boundary condition on the computational domain boundary and has the advantage of maintaining purely local coupling of mesh elements. We use this new capability to simulate perturbed, free-boundary non- axisymmetric equilibria; the linear evolution of resistive wall modes; and the linear andmore » nonlinear evolution of axisymmetric vertical displacement events (VDEs). Calculated growth rates for a resistive wall mode with arbitrary wall thickness are shown to agree well with the analytic theory. Equilibrium and VDE calculations are performed in diverted tokamak geometry, at physically real- istic values of dissipation, and with resistive walls of finite width. Simulations of a VDE disruption extend into the current-quench phase, in which the plasma becomes limited by the first wall, and strong currents are observed to flow in the wall, in the SOL, and from the plasma to the wall.« less

  14. Multi-region approach to free-boundary three-dimensional tokamak equilibria and resistive wall instabilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferraro, N. M., E-mail: nferraro@pppl.gov; Lao, L. L.; Jardin, S. C.

    Free-boundary 3D tokamak equilibria and resistive wall instabilities are calculated using a new resistive wall model in the two-fluid M3D-C1 code. In this model, the resistive wall and surrounding vacuum region are included within the computational domain. This implementation contrasts with the method typically used in fluid codes in which the resistive wall is treated as a boundary condition on the computational domain boundary and has the advantage of maintaining purely local coupling of mesh elements. This new capability is used to simulate perturbed, free-boundary non-axisymmetric equilibria; the linear evolution of resistive wall modes; and the linear and nonlinear evolutionmore » of axisymmetric vertical displacement events (VDEs). Calculated growth rates for a resistive wall mode with arbitrary wall thickness are shown to agree well with the analytic theory. Equilibrium and VDE calculations are performed in diverted tokamak geometry, at physically realistic values of dissipation, and with resistive walls of finite width. Simulations of a VDE disruption extend into the current-quench phase, in which the plasma becomes limited by the first wall, and strong currents are observed to flow in the wall, in the SOL, and from the plasma to the wall.« less

  15. Multi-region approach to free-boundary three-dimensional tokamak equilibria and resistive wall instabilities

    DOE PAGES

    Ferraro, N. M.; Jardin, S. C.; Lao, L. L.; ...

    2016-05-20

    Free-boundary 3D tokamak equilibria and resistive wall instabilities are calculated using a new resistive wall model in the two-fluid M3D-C1 code. In this model, the resistive wall and surround- ing vacuum region are included within the computational domain. Our implementation contrasts with the method typically used in fluid codes in which the resistive wall is treated as a boundary condition on the computational domain boundary and has the advantage of maintaining purely local coupling of mesh elements. We use this new capability to simulate perturbed, free-boundary non- axisymmetric equilibria; the linear evolution of resistive wall modes; and the linear andmore » nonlinear evolution of axisymmetric vertical displacement events (VDEs). Calculated growth rates for a resistive wall mode with arbitrary wall thickness are shown to agree well with the analytic theory. Equilibrium and VDE calculations are performed in diverted tokamak geometry, at physically real- istic values of dissipation, and with resistive walls of finite width. Simulations of a VDE disruption extend into the current-quench phase, in which the plasma becomes limited by the first wall, and strong currents are observed to flow in the wall, in the SOL, and from the plasma to the wall.« less

  16. Analysis of the vibratory excitation arising from spiral bevel gears

    NASA Technical Reports Server (NTRS)

    Mark, William D.

    1987-01-01

    Tools required to understand and predict in terms of its underlying causes the vibratory excitation arising from meshing spiral bevel gears are developed. A generalized three component transmission error of meshing spiral bevel gears is defined. Equations are derived that yield the three components of the generalized transmission error in terms of deviations of tooth running surfaces from equispaced perfect spherical involute surfaces and tooth/gearbody elastic deformations arising from the three components of the generalized force transmitted by the meshing gears. A method for incorporating these equations into the equations of motion of a gear system is described. Equations are derived for the three components of the generalized force transmitted by the gears which are valid whenever inertial effects of the meshing gears and their supports are negligible. Bearing offsets from the positions occupied by the shaft centerlines of perfect spherical involute bevel gears and bearing/bearing support flexibilities enter into the computation of these forces.

  17. Predicted effect of dynamic load on pitting fatigue life for low-contact-ratio spur gears

    NASA Technical Reports Server (NTRS)

    Lewicki, David G.

    1986-01-01

    How dynamic load affects the surface pitting fatigue life of external spur gears was predicted by using the NASA computer program TELSGE. Parametric studies were performed over a range of various gear parameters modeling low-contact-ratio involute spur gears. In general, gear life predictions based on dynamic loads differed significantly from those based on static loads, with the predictions being strongly influenced by the maximum dynamic load during contact. Gear mesh operating speed strongly affected predicted dynamic load and life. Meshes operating at a resonant speed or one-half the resonant speed had significantly shorter lives. Dynamic life factors for gear surface pitting fatigue were developed on the basis of the parametric studies. In general, meshes with higher contact ratios had higher dynamic life factors than meshes with lower contact ratios. A design chart was developed for hand calculations of dynamic life factors.

  18. [Skeleton extractions and applications].

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quadros, William Roshan

    2010-05-01

    This paper focuses on the extraction of skeletons of CAD models and its applications in finite element (FE) mesh generation. The term 'skeleton of a CAD model' can be visualized as analogous to the 'skeleton of a human body'. The skeletal representations covered in this paper include medial axis transform (MAT), Voronoi diagram (VD), chordal axis transform (CAT), mid surface, digital skeletons, and disconnected skeletons. In the literature, the properties of a skeleton have been utilized in developing various algorithms for extracting skeletons. Three main approaches include: (1) the bisection method where the skeleton exists at equidistant from at leastmore » two points on boundary, (2) the grassfire propagation method in which the skeleton exists where the opposing fronts meet, and (3) the duality method where the skeleton is a dual of the object. In the last decade, the author has applied different skeletal representations in all-quad meshing, hex meshing, mid-surface meshing, mesh size function generation, defeaturing, and decomposition. A brief discussion on the related work from other researchers in the area of tri meshing, tet meshing, and anisotropic meshing is also included. This paper concludes by summarizing the strengths and weaknesses of the skeleton-based approaches in solving various geometry-centered problems in FE mesh generation. The skeletons have proved to be a great shape abstraction tool in analyzing the geometric complexity of CAD models as they are symmetric, simpler (reduced dimension), and provide local thickness information. However, skeletons generally require some cleanup, and stability and sensitivity of the skeletons should be controlled during extraction. Also, selecting a suitable application-specific skeleton and a computationally efficient method of extraction is critical.« less

  19. Differential geometry based model for eddy current inspection of U-bend sections in steam generator tubes

    NASA Astrophysics Data System (ADS)

    Mukherjee, Saptarshi; Rosell, Anders; Udpa, Lalita; Udpa, Satish; Tamburrino, Antonello

    2017-02-01

    The modeling of U-Bend segment in steam generator tubes for predicting eddy current probe signals from cracks, wear and pitting in this region poses challenges and is non-trivial. Meshing the geometry in the cartesian coordinate system might require a large number of elements to model the U-bend region. Also, since the lift-off distance between the probe and tube wall is usually very small, a very fine mesh is required near the probe region to accurately describe the eddy current field. This paper presents a U-bend model using differential geometry principles that exploit the result that Maxwell's equations are covariant with respect to changes of coordinates and independent of metrics. The equations remain unaltered in their form, regardless of the choice of the coordinates system, provided the field quantities are represented in the proper covariant and contravariant form. The complex shapes are mapped into simple straight sections, while small lift-off is mapped to larger values, thus reducing the intrinsic dimension of the mesh and stiffness matrix. In this contribution, the numerical implementation of the above approach will be discussed with regard to field and current distributions within the U-bend tube wall. For the sake of simplicity, a two dimensional test case will be considered. The approach is evaluated in terms of efficiency and accuracy by comparing the results with that obtained using a conventional FE model in cartesian coordinates.

  20. Simulation of violent free surface flow by AMR method

    NASA Astrophysics Data System (ADS)

    Hu, Changhong; Liu, Cheng

    2018-05-01

    A novel CFD approach based on adaptive mesh refinement (AMR) technique is being developed for numerical simulation of violent free surface flows. CIP method is applied to the flow solver and tangent of hyperbola for interface capturing with slope weighting (THINC/SW) scheme is implemented as the free surface capturing scheme. The PETSc library is adopted to solve the linear system. The linear solver is redesigned and modified to satisfy the requirement of the AMR mesh topology. In this paper, our CFD method is outlined and newly obtained results on numerical simulation of violent free surface flows are presented.

  1. Merge measuring mesh for complex surface parts

    NASA Astrophysics Data System (ADS)

    Ye, Jianhua; Gao, Chenghui; Zeng, Shoujin; Xu, Mingsan

    2018-04-01

    Due to most parts self-occlude and limitation of scanner range, it is difficult to scan the entire part by one time. For modeling of part, multi measuring meshes need to be merged. In this paper, a new merge method is presented. At first, using the grid voxelization method to eliminate the most of non-overlap regions, and retrieval overlap triangles method by the topology of mesh is proposed due to its ability to improve the efficiency. Then, to remove the large deviation of overlap triangles, deleting by overlap distance is discussion. After that, this paper puts forward a new method of merger meshes by registration and combination mesh boundary point. Through experimental analysis, the suggested methods are effective.

  2. Virtual 3D bladder reconstruction for augmented medical records from white light cystoscopy (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Lurie, Kristen L.; Zlatev, Dimitar V.; Angst, Roland; Liao, Joseph C.; Ellerbee, Audrey K.

    2016-02-01

    Bladder cancer has a high recurrence rate that necessitates lifelong surveillance to detect mucosal lesions. Examination with white light cystoscopy (WLC), the standard of care, is inherently subjective and data storage limited to clinical notes, diagrams, and still images. A visual history of the bladder wall can enhance clinical and surgical management. To address this clinical need, we developed a tool to transform in vivo WLC videos into virtual 3-dimensional (3D) bladder models using advanced computer vision techniques. WLC videos from rigid cystoscopies (1280 x 720 pixels) were recorded at 30 Hz followed by immediate camera calibration to control for image distortions. Video data were fed into an automated structure-from-motion algorithm that generated a 3D point cloud followed by a 3D mesh to approximate the bladder surface. The highest quality cystoscopic images were projected onto the approximated bladder surface to generate a virtual 3D bladder reconstruction. In intraoperative WLC videos from 36 patients undergoing transurethral resection of suspected bladder tumors, optimal reconstruction was achieved from frames depicting well-focused vasculature, when the bladder was maintained at constant volume with minimal debris, and when regions of the bladder wall were imaged multiple times. A significant innovation of this work is the ability to perform the reconstruction using video from a clinical procedure collected with standard equipment, thereby facilitating rapid clinical translation, application to other forms of endoscopy and new opportunities for longitudinal studies of cancer recurrence.

  3. Surface controlled biomimetic coating of polycaprolactone nanofiber meshes to be used as bone extracellular matrix analogues.

    PubMed

    Araujo, J V; Martins, A; Leonor, I B; Pinho, E D; Reis, R L; Neves, N M

    2008-01-01

    The aim of this work was to develop novel electrospun nanofiber meshes coated with a biomimetic calcium phosphate (BCP) layer that mimics the extracellular microenvironment found in the human bone structure. Poly (epsilon-caprolactone) (PCL) was selected because of its well-known medical applications, its biodegradability, biocompatibility and its susceptibility to partial hydrolysis by a straightforward alkaline treatment. The deposition of a calcium phosphate layer, similar to the inorganic phase of bone, on PCL nanofiber meshes was achieved by means of a surface modification. This initial surface modification was followed by treatment with solutions containing calcium and phosphate ions. The process was finished by a posterior immersion in a simulated body fluid (SBF) with nearly 1.5 x the inorganic concentration of the human blood plasma ions. After some optimization work, the best conditions were chosen to perform the biological assays. The influence of the bone-like BCP layer on the viability and adhesion, as well as on the proliferation of human osteoblast-like cells, was assessed. It was shown that PCL nanofiber meshes coated with a BCP layer support and enhance the proliferation of osteoblasts for long culture periods. The attractive properties of the coated structures produced in the present work demonstrated that those materials have potential to be used for applications in bone tissue engineering. This is the first time that nanofiber meshes could be coated with a biomimetic bone-like calcium phosphate layer produced in a way that the original mesh architecture can be fully maintained.

  4. Nonlinear analysis of composite thin-walled helicopter blades

    NASA Astrophysics Data System (ADS)

    Kalfon, J. P.; Rand, O.

    Nonlinear theoretical modeling of laminated thin-walled composite helicopter rotor blades is presented. The derivation is based on nonlinear geometry with a detailed treatment of the body loads in the axial direction which are induced by the rotation. While the in-plane warping is neglected, a three-dimensional generic out-of-plane warping distribution is included. The formulation may also handle varying thicknesses and mass distribution along the cross-sectional walls. The problem is solved by successive iterations in which a system of equations is constructed and solved for each cross-section. In this method, the differential equations in the spanwise directions are formulated and solved using a finite-differences scheme which allows simple adaptation of the spanwise discretization mesh during iterations.

  5. Effect of platelet-rich plasma on polypropylene meshes implanted in the rabbit vagina: histological analysis.

    PubMed

    Parizzi, Natália Gomes; Rubini, Oscar Ávila; Almeida, Silvio Henrique Maia de; Ireno, Lais Caetano; Tashiro, Roger Mitio; Carvalho, Victor Hugo Tolotto de

    2017-01-01

    The polypropylene mesh (PPM) is used in many surgical interventions because of its good incorporation and accessibility. However, potential mesh-related complications are common. Platelet-rich plasma (PRP) improves the healing of wounds and is inexpensive. Thus, the purpose of this study was to analyze the effect of the PRP-gel coating of a PPM on inflammation, production of collagen, and smooth muscle in the rabbit vagina. The intervention consisted of a 1.5cm incision and divulsion of the vaginal mucosa for the implantation of a PRP-coated PPM. The PRP-coated mesh was implanted in 15 rabbits, and in the second group, the same implant was used without the PRP coating. In the sham group, the intervention consisted of the incision, divulsion, and suture. The rabbits were euthanized at 7, 30 and 90 days, and full-thickness sagittal sections of the posterior vaginal wall and rectum were scored. The inflammatory infiltrate was evaluated using hematoxylin and eosin staining. The Sirius Red stain was used to examine deposition of collagen I and III, and Masson's trichrome staining was used to visualize the smooth muscle. The group with PRP-coated meshes had a lower inflammatory infiltrate count at 30 days. Deposition of collagen III increased with the use of PRP-coating at 90 days. The area of inflammatory infiltrate was significantly increased in the group without the PRP-coated mesh at 30 days but not in the group with the PRPcoated mesh, indicating a less intense inflammatory response. In addition, a significant increase in collagen III occurred at 90 days. Copyright® by the International Brazilian Journal of Urology.

  6. Generalized interactions using virtual tools within the spring framework: cutting

    NASA Technical Reports Server (NTRS)

    Montgomery, Kevin; Bruyns, Cynthia D.

    2002-01-01

    We present schemes for real-time generalized mesh cutting. Starting with the a basic example, we describe the details of implementing cutting on single and multiple surface objects as well as hybrid and volumetric meshes using virtual tools with single and multiple cutting surfaces. These methods have been implemented in a robust surgical simulation environment allowing us to model procedures ranging from animal dissection to cleft lip correction.

  7. Control surface hinge moment prediction using computational fluid dynamics

    NASA Astrophysics Data System (ADS)

    Simpson, Christopher David

    The following research determines the feasibility of predicting control surface hinge moments using various computational methods. A detailed analysis is conducted using a 2D GA(W)-1 airfoil with a 20% plain flap. Simple hinge moment prediction methods are tested, including empirical Datcom relations and XFOIL. Steady-state and time-accurate turbulent, viscous, Navier-Stokes solutions are computed using Fun3D. Hinge moment coefficients are computed. Mesh construction techniques are discussed. An adjoint-based mesh adaptation case is also evaluated. An NACA 0012 45-degree swept horizontal stabilizer with a 25% elevator is also evaluated using Fun3D. Results are compared with experimental wind-tunnel data obtained from references. Finally, the costs of various solution methods are estimated. Results indicate that while a steady-state Navier-Stokes solution can accurately predict control surface hinge moments for small angles of attack and deflection angles, a time-accurate solution is necessary to accurately predict hinge moments in the presence of flow separation. The ability to capture the unsteady vortex shedding behavior present in moderate to large control surface deflections is found to be critical to hinge moment prediction accuracy. Adjoint-based mesh adaptation is shown to give hinge moment predictions similar to a globally-refined mesh for a steady-state 2D simulation.

  8. A computational method for sharp interface advection

    PubMed Central

    Bredmose, Henrik; Jasak, Hrvoje

    2016-01-01

    We devise a numerical method for passive advection of a surface, such as the interface between two incompressible fluids, across a computational mesh. The method is called isoAdvector, and is developed for general meshes consisting of arbitrary polyhedral cells. The algorithm is based on the volume of fluid (VOF) idea of calculating the volume of one of the fluids transported across the mesh faces during a time step. The novelty of the isoAdvector concept consists of two parts. First, we exploit an isosurface concept for modelling the interface inside cells in a geometric surface reconstruction step. Second, from the reconstructed surface, we model the motion of the face–interface intersection line for a general polygonal face to obtain the time evolution within a time step of the submerged face area. Integrating this submerged area over the time step leads to an accurate estimate for the total volume of fluid transported across the face. The method was tested on simple two-dimensional and three-dimensional interface advection problems on both structured and unstructured meshes. The results are very satisfactory in terms of volume conservation, boundedness, surface sharpness and efficiency. The isoAdvector method was implemented as an OpenFOAM® extension and is published as open source. PMID:28018619

  9. Manual for automatic generation of finite element models of spiral bevel gears in mesh

    NASA Technical Reports Server (NTRS)

    Bibel, G. D.; Reddy, S.; Kumar, A.

    1994-01-01

    The goal of this research is to develop computer programs that generate finite element models suitable for doing 3D contact analysis of faced milled spiral bevel gears in mesh. A pinion tooth and a gear tooth are created and put in mesh. There are two programs: Points.f and Pat.f to perform the analysis. Points.f is based on the equation of meshing for spiral bevel gears. It uses machine tool settings to solve for an N x M mesh of points on the four surfaces, pinion concave and convex, and gear concave and convex. Points.f creates the file POINTS.OUT, an ASCI file containing N x M points for each surface. (N is the number of node points along the length of the tooth, and M is nodes along the height.) Pat.f reads POINTS.OUT and creates the file tl.out. Tl.out is a series of PATRAN input commands. In addition to the mesh density on the tooth face, additional user specified variables are the number of finite elements through the thickness, and the number of finite elements along the tooth full fillet. A full fillet is assumed to exist for both the pinion and gear.

  10. Influence of reinforcement mesh configuration for improvement of concrete durability

    NASA Astrophysics Data System (ADS)

    Pan, Chong-gen; Jin, Wei-liang; Mao, Jiang-hong; Zhang, Hua; Sun, Li-hao; Wei, Dong

    2017-10-01

    Steel bar in concrete structures under harsh environmental conditions, such as chlorine corrosion, seriously affects its service life. Bidirectional electromigration rehabilitation (BIEM) is a new method of repair technology for reinforced concrete structures in such chloride corrosion environments. By applying the BIEM, chloride ions can be removed from the concrete and the migrating corrosion inhibit can be moved to the steel surface. In conventional engineering, the concrete structure is often configured with a multi-layer steel mesh. However, the effect of the BIEM in such structures has not yet been investigated. In this paper, the relevant simulation test is carried out to study the migration law of chloride ions and the migrating corrosion inhibitor in a concrete specimen with complex steel mesh under different energizing modes. The results show that the efficiency of the BIEM increases 50% in both the monolayer steel mesh and the double-layer steel mesh. By using the single-sided BIEM, 87% of the chloride ions are removed from the steel surface. The different step modes can affect the chloride ion removal. The chloride ions within the range of the reinforcement protective cover are easier to be removed than those in the concrete between the two layers of steel mesh. However, the amount of migrating corrosion inhibitor is larger in the latter circumstances.

  11. Fabrication of superhydrophobic nano-aluminum films on stainless steel meshes by electrophoretic deposition for oil-water separation

    NASA Astrophysics Data System (ADS)

    Xu, Zhe; Jiang, Deyi; Wei, Zhibo; Chen, Jie; Jing, Jianfeng

    2018-01-01

    Stainless steel meshes with superhydrophobic surfaces were successfully fabricated via a facile electrophoretic deposition process. The surface morphology and chemical compositions were characterized by a field emission scanning electron microscope (FE-SEM), energy-dispersive X-ray spectroscope (EDS), X-ray diffraction (XRD) and fourier-transform infrared spectrophotometer (FTIR). After stearic acid modification, the obtained nano-aluminum films on stainless steel meshes showed an excellent superhydrophobic properties with a water contact angle of 160° ± 1.2° and a water sliding angle of less than 5°. In addition, on the basis of the superhydrophobic meshes, a simple, continuous oil-water separation apparatus was designed, and the oil-water separation efficiency was up to 95.8% ± 0.9%. Meanwhile, after 20 oil-water separation cycles, the separation efficiency without significant reduction suggested the stable performance of superhydrophobic stainless steel meshes on the oil-water separation. Moreover, the flow rate of oil-water mixture and effective separation length were investigated to determine their effects on the oil-water separation efficiency, respectively. Our work provides a cost-efficient method to prepare stable superhydrophobic nano-Al films on stainless steel meshes, and it has promising practical applications on oil-water separation.

  12. Conversion of Component-Based Point Definition to VSP Model and Higher Order Meshing

    NASA Technical Reports Server (NTRS)

    Ordaz, Irian

    2011-01-01

    Vehicle Sketch Pad (VSP) has become a powerful conceptual and parametric geometry tool with numerous export capabilities for third-party analysis codes as well as robust surface meshing capabilities for computational fluid dynamics (CFD) analysis. However, a capability gap currently exists for reconstructing a fully parametric VSP model of a geometry generated by third-party software. A computer code called GEO2VSP has been developed to close this gap and to allow the integration of VSP into a closed-loop geometry design process with other third-party design tools. Furthermore, the automated CFD surface meshing capability of VSP are demonstrated for component-based point definition geometries in a conceptual analysis and design framework.

  13. Effect of boundary representation on viscous, separated flows in a discontinuous-Galerkin Navier-Stokes solver

    NASA Astrophysics Data System (ADS)

    Nelson, Daniel A.; Jacobs, Gustaaf B.; Kopriva, David A.

    2016-08-01

    The effect of curved-boundary representation on the physics of the separated flow over a NACA 65(1)-412 airfoil is thoroughly investigated. A method is presented to approximate curved boundaries with a high-order discontinuous-Galerkin spectral element method for the solution of the Navier-Stokes equations. Multiblock quadrilateral element meshes are constructed with the grid generation software GridPro. The boundary of a NACA 65(1)-412 airfoil, defined by a cubic natural spline, is piecewise-approximated by isoparametric polynomial interpolants that represent the edges of boundary-fitted elements. Direct numerical simulation of the airfoil is performed on a coarse mesh and fine mesh with polynomial orders ranging from four to twelve. The accuracy of the curve fitting is investigated by comparing the flows computed on curved-sided meshes with those given by straight-sided meshes. Straight-sided meshes yield irregular wakes, whereas curved-sided meshes produce a regular Karman street wake. Straight-sided meshes also produce lower lift and higher viscous drag as compared with curved-sided meshes. When the mesh is refined by reducing the sizes of the elements, the lift decrease and viscous drag increase are less pronounced. The differences in the aerodynamic performance between the straight-sided meshes and the curved-sided meshes are concluded to be the result of artificial surface roughness introduced by the piecewise-linear boundary approximation provided by the straight-sided meshes.

  14. Domain Immersion Technique And Free Surface Computations Applied To Extrusion And Mixing Processes

    NASA Astrophysics Data System (ADS)

    Valette, Rudy; Vergnes, Bruno; Basset, Olivier; Coupez, Thierry

    2007-04-01

    This work focuses on the development of numerical techniques devoted to the simulation of mixing processes of complex fluids such as twin-screw extrusion or batch mixing. In mixing process simulation, the absence of symmetry of the moving boundaries (the screws or the rotors) implies that their rigid body motion has to be taken into account by using a special treatment. We therefore use a mesh immersion technique (MIT), which consists in using a P1+/P1-based (MINI-element) mixed finite element method for solving the velocity-pressure problem and then solving the problem in the whole barrel cavity by imposing a rigid motion (rotation) to nodes found located inside the so called immersed domain, each subdomain (screw, rotor) being represented by a surface CAD mesh (or its mathematical equation in simple cases). The independent meshes are immersed into a unique backgound computational mesh by computing the distance function to their boundaries. Intersections of meshes are accounted for, allowing to compute a fill factor usable as for the VOF methodology. This technique, combined with the use of parallel computing, allows to compute the time-dependent flow of generalized Newtonian fluids including yield stress fluids in a complex system such as a twin screw extruder, including moving free surfaces, which are treated by a "level set" and Hamilton-Jacobi method.

  15. Ag nanoparticles loading of polypyrrole-coated superwetting mesh for on-demand separation of oil-water mixtures and catalytic reduction of aromatic dyes.

    PubMed

    Yihan, Sun; Mingming, Liu; Guo, Zhiguang

    2018-05-19

    Herein, a catalytic mesh with unique wettability, high oil-water separation efficiency and excellent catalytic performance towards aromatic dyes was fabricated. Polypyrrole (PPy) was firstly pre-coated on pristine stainless-steel mesh (SSM) surface via cyclic voltammetry approach. Subsequently, a simple electrodeposition process was performed to prepare and anchor Ag nanoparticles (AgNPs) onto the PPy-coated SSM surface. The PPy-coated mesh with anchored AgNPs was denoted as PPy/AgNPs-coated SSM. The obtained PPy/AgNPs-coated SSM exhibited dual superlyophobic properties and were able to achieve on-demand separation to deal with various of light oil (ρ oil  < ρ water ) and heavy oil (ρ oil  > ρ water )-water mixtures. Importantly, benefitting from AgNPs on mesh surface, the obtained PPy/AgNPs-coated SSM exhibits exceptional catalytic activity. As proof-of-concept three typical aromatic dye molecules (methylene blue, rhodamine B and Congo red) can be effectivity degraded. Additionally, the degradation of aromatic dyes and oil-water separation were achieved simultaneously when the PPy/AgNPs-coated SSM was converted to water-removing mode. Therefore, the present work is of great significance to the development of novel oil-water filtration membranes and can open a new avenue towards the practicability of metal nanoparticle catalysts in wastewater treatment. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Spaceborne Microwave Instrument for High Resolution Remote Sensing of the Earth's Surface Using a Large-Aperture Mesh Antenna

    NASA Technical Reports Server (NTRS)

    Njoku, E.; Wilson, W.; Yueh, S.; Freeland, R.; Helms, R.; Edelstein, W.; Sadowy, G.; Farra, D.; West, R.; Oxnevad, K.

    2001-01-01

    This report describes a two-year study of a large-aperture, lightweight, deployable mesh antenna system for radiometer and radar remote sensing of the Earth from space. The study focused specifically on an instrument to measure ocean salinity and Soil moisture. Measurements of ocean salinity and soil moisture are of critical . importance in improving knowledge and prediction of key ocean and land surface processes, but are not currently obtainable from space. A mission using this instrument would be the first demonstration of deployable mesh antenna technology for remote sensing and could lead to potential applications in other remote sensing disciplines that require high spatial resolution measurements. The study concept features a rotating 6-m-diameter deployable mesh antenna, with radiometer and radar sensors, to measure microwave emission and backscatter from the Earth's surface. The sensors operate at L and S bands, with multiple polarizations and a constant look angle, scanning across a wide swath. The study included detailed analyses of science requirements, reflector and feedhorn design and performance, microwave emissivity measurements of mesh samples, design and test of lightweight radar electronic., launch vehicle accommodations, rotational dynamics simulations, and an analysis of attitude control issues associated with the antenna and spacecraft, The goal of the study was to advance the technology readiness of the overall concept to a level appropriate for an Earth science emission.

  17. Multiresolution Distance Volumes for Progressive Surface Compression

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laney, D E; Bertram, M; Duchaineau, M A

    2002-04-18

    We present a surface compression method that stores surfaces as wavelet-compressed signed-distance volumes. Our approach enables the representation of surfaces with complex topology and arbitrary numbers of components within a single multiresolution data structure. This data structure elegantly handles topological modification at high compression rates. Our method does not require the costly and sometimes infeasible base mesh construction step required by subdivision surface approaches. We present several improvements over previous attempts at compressing signed-distance functions, including an 0(n) distance transform, a zero set initialization method for triangle meshes, and a specialized thresholding algorithm. We demonstrate the potential of sampled distancemore » volumes for surface compression and progressive reconstruction for complex high genus surfaces.« less

  18. Wind Farm LES Simulations Using an Overset Methodology

    NASA Astrophysics Data System (ADS)

    Ananthan, Shreyas; Yellapantula, Shashank

    2017-11-01

    Accurate simulation of wind farm wakes under realistic atmospheric inflow conditions and complex terrain requires modeling a wide range of length and time scales. The computational domain can span several kilometers while requiring mesh resolutions in O(10-6) to adequately resolve the boundary layer on the blade surface. Overset mesh methodology offers an attractive option to address the disparate range of length scales; it allows embedding body-confirming meshes around turbine geomtries within nested wake capturing meshes of varying resolutions necessary to accurately model the inflow turbulence and the resulting wake structures. Dynamic overset hole-cutting algorithms permit relative mesh motion that allow this nested mesh structure to track unsteady inflow direction changes, turbine control changes (yaw and pitch), and wake propagation. An LES model with overset mesh for localized mesh refinement is used to analyze wind farm wakes and performance and compared with local mesh refinements using non-conformal (hanging node) unstructured meshes. Turbine structures will be modeled using both actuator line approaches and fully-resolved structures to test the efficacy of overset methods for wind farm applications. Exascale Computing Project (ECP), Project Number: 17-SC-20-SC, a collaborative effort of two DOE organizations - the Office of Science and the National Nuclear Security Administration.

  19. The cause and resolution of log-layer mismatch in wall-modeled LES: a new perspective and its implication in complex flows

    NASA Astrophysics Data System (ADS)

    Park, George; Yang, Xiang; Moin, Parviz

    2017-11-01

    Log-layer mismatch (LLM) refers to the erroneous shifts of the mean velocity profile in the log-law region when wall models are coupled to the LES solution at the first off-wall grid points. It is often believed that the discretization error and subgrid-scale modeling error in the highly under resolved near-wall region contaminates the first off-wall LES solution, thereby providing inaccurate input to wall models resulting in inaccurate wall shear stress. Placing the LES/wall-model interface a couple of cells away from the wall has been recommended to avoid LLM. However, its non-local nature render this method impractical for flows involving complex geometry, by incurring significant overhead in LES mesh preparation and wall-model implementation. We propose an alternative remedy for LLM which warrants the removal of LLM while utilizing the first off-wall LES data. The method is based on filtering the wall-model input either in space or in time. It is simple, easy to implement, and would be particularly well suited for unstructured-grid LES involving complex geometries. We also demonstrate that LLM is caused by excessive correlation between the wall-model input and its wall shear stress output. This research is sponsored by NASA (NNX15AU93A) and ONR (FA9550-16-1-0319).

  20. On The Aerodynamic Heating Of Vega Launcher: Compressible Chimera Navier-Stokes Simulation With Complex Surfaces

    NASA Astrophysics Data System (ADS)

    Di Mascio, A.; Zaghi, S.; Muscari, R.; Broglia, R.; Cavallini, E.; Favini, B.; Scaccia, A.

    2011-05-01

    The results of accurate compressible Navier-Stokes simulations of aerodynamic heating of the Vega launcher are presented. Three selected steady conditions of the Vega mission profile are considered: the first corresponding to the altitude of 18 km, the second to 25 km and the last to 33 km. The numerical code is based on the Favre- Average Navier-Stokes equations; the turbulent model chosen for closure is the one-equation model by Spalart- Allmaras. The equations are discretized by a finite volume approach, that can handle block-structured meshes with partial overlap (“Chimera” grid-overlapping technique). The isothermal boundary condition has been applied to the lancher wall. Particular care was devoted to the construction of the discrete model; indeed, the launcher is equipped with many protrusions and geometrical peculiarities (as antennas, raceways, inter-stage connection flanges and retrorockets) that are expected to affect considerably the local thermal flow-field and the level of heat fluxes, because the flow have to undergo strong variation in space; con- sequently, special attention was devoted to the definition of a tailored mesh, capable of catching local details of the aerothermal flow field (shocks, expansion fans, boundary layer, etc..). The computed results are reported together with uncertainty and actual convergence order, that were estimated by the standard procedures suggested by AIAA [Ame98].

  1. Gaussian curvature analysis allows for automatic block placement in multi-block hexahedral meshing.

    PubMed

    Ramme, Austin J; Shivanna, Kiran H; Magnotta, Vincent A; Grosland, Nicole M

    2011-10-01

    Musculoskeletal finite element analysis (FEA) has been essential to research in orthopaedic biomechanics. The generation of a volumetric mesh is often the most challenging step in a FEA. Hexahedral meshing tools that are based on a multi-block approach rely on the manual placement of building blocks for their mesh generation scheme. We hypothesise that Gaussian curvature analysis could be used to automatically develop a building block structure for multi-block hexahedral mesh generation. The Automated Building Block Algorithm incorporates principles from differential geometry, combinatorics, statistical analysis and computer science to automatically generate a building block structure to represent a given surface without prior information. We have applied this algorithm to 29 bones of varying geometries and successfully generated a usable mesh in all cases. This work represents a significant advancement in automating the definition of building blocks.

  2. A Nonlinear Dynamic Model and Free Vibration Analysis of Deployable Mesh Reflectors

    NASA Technical Reports Server (NTRS)

    Shi, H.; Yang, B.; Thomson, M.; Fang, H.

    2011-01-01

    This paper presents a dynamic model of deployable mesh reflectors, in which geometric and material nonlinearities of such a space structure are fully described. Then, by linearization around an equilibrium configuration of the reflector structure, a linearized model is obtained. With this linearized model, the natural frequencies and mode shapes of a reflector can be computed. The nonlinear dynamic model of deployable mesh reflectors is verified by using commercial finite element software in numerical simulation. As shall be seen, the proposed nonlinear model is useful for shape (surface) control of deployable mesh reflectors under thermal loads.

  3. Calculation of steady and unsteady transonic flow using a Cartesian mesh and gridless boundary conditions with application to aeroelasticity

    NASA Astrophysics Data System (ADS)

    Kirshman, David

    A numerical method for the solution of inviscid compressible flow using an array of embedded Cartesian meshes in conjunction with gridless surface boundary conditions is developed. The gridless boundary treatment is implemented by means of a least squares fitting of the conserved flux variables using a cloud of nodes in the vicinity of the surface geometry. The method allows for accurate treatment of the surface boundary conditions using a grid resolution an order of magnitude coarser than required of typical Cartesian approaches. Additionally, the method does not suffer from issues associated with thin body geometry or extremely fine cut cells near the body. Unlike some methods that consider a gridless (or "meshless") treatment throughout the entire domain, multi-grid acceleration can be effectively incorporated and issues associated with global conservation are alleviated. The "gridless" surface boundary condition provides for efficient and simple problem set up since definition of the body geometry is generated independently from the field mesh, and automatically incorporated into the field discretization of the domain. The applicability of the method is first demonstrated for steady flow of single and multi-element airfoil configurations. Using this method, comparisons with traditional body-fitted grid simulations reveal that steady flow solutions can be obtained accurately with minimal effort associated with grid generation. The method is then extended to unsteady flow predictions. In this application, flow field simulations for the prescribed oscillation of an airfoil indicate excellent agreement with experimental data. Furthermore, it is shown that the phase lag associated with shock oscillation is accurately predicted without the need for a deformable mesh. Lastly, the method is applied to the prediction of transonic flutter using a two-dimensional wing model, in which comparisons with moving mesh simulations yield nearly identical results. As a result, applicability of the method to transient and vibrating fluid-structure interaction problems is established in which the requirement for a deformable mesh is eliminated.

  4. Necrotising fasciitis after hysterectomy and concomitant transvaginal mesh repair in a patient with pelvic organ prolapse.

    PubMed

    Pushkar, Dmitry Y; Vasilchenko, Mikhail I; Kasyan, George R

    2013-10-01

    Necrotising fasciitis is a severe form of soft tissue infection. Herein, we present an unreported complication of the transvaginal repair of a pelvic organ prolapse (POP) with trocar-guided polypropylene mesh and a concomitant hysterectomy. A 61-year-old Caucasian female who had been using an intrauterine device (IUD) for 30 years presented with a stage 3 pelvic organ prolapse. A genital ultrasound examination confirmed the presence of an IUD, but found no endometrial abnormalities. The surgical management was limited to a transvaginal hysterectomy and simultaneous anterior vaginal wall repair augmented with trocar-guided mesh. A morphological examination of the removed uterus confirmed the presence of the intrauterine device and additionally found endometrial cancer (T1N0M0), which was not revealed during the preoperative ultrasound. Within 6 days of the surgery, she developed anaerobic bilateral necrotising fasciitis on both thighs. Non-clostridial streptococci were identified in the wound. After 18 days of intensive care, the patient died of fatal coagulopathy.

  5. Particle systems for adaptive, isotropic meshing of CAD models

    PubMed Central

    Levine, Joshua A.; Whitaker, Ross T.

    2012-01-01

    We present a particle-based approach for generating adaptive triangular surface and tetrahedral volume meshes from computer-aided design models. Input shapes are treated as a collection of smooth, parametric surface patches that can meet non-smoothly on boundaries. Our approach uses a hierarchical sampling scheme that places particles on features in order of increasing dimensionality. These particles reach a good distribution by minimizing an energy computed in 3D world space, with movements occurring in the parametric space of each surface patch. Rather than using a pre-computed measure of feature size, our system automatically adapts to both curvature as well as a notion of topological separation. It also enforces a measure of smoothness on these constraints to construct a sizing field that acts as a proxy to piecewise-smooth feature size. We evaluate our technique with comparisons against other popular triangular meshing techniques for this domain. PMID:23162181

  6. Studies on the structure of the boundary tissue of the white rat seminiferous tubules.

    PubMed

    Cieciura, L

    1988-01-01

    The studies on boundary tissue of the white rat seminiferous tubules with light and electron microscopy were carried out. The wall of the tubules consists of four layers: two cellular and two amorphous ones. In cellular external sheath the characteristic intercellular fissures a network of hexagonal meshes were seen resembling the honey-combs.

  7. Magnetic Shielding of the Channel Walls in a Hall Plasma Accelerator

    NASA Technical Reports Server (NTRS)

    Mikellides, Ioannis G.; Katz, Ira; Hofer, Richard R.; Goebel, Dan M.; deGrys, Kristi; Mathers, Alex

    2011-01-01

    In a qualification life test of a Hall thruster it was found that the erosion of the acceleration channel practically stopped after approx 5,600 h. Numerical simulations using a two-dimensional axisymmetric plasma solver with a magnetic field-aligned mesh reveal that when the channel receded from its early-in-life to its steady-state configuration the following changes occurred near the wall: (1) reduction of the electric field parallel to the wall that prohibited ions from acquiring significant impact kinetic energy before entering the sheath, (2) reduction of the potential fall in the sheath that further diminished the total energy ions gained before striking the material, and (3) reduction of the ion number density that decreased the flux of ions to the wall. All these changes, found to have been induced by the magnetic field, constituted collectively an effective shielding of the walls from any significant ion bombardment. Thus, we term this process in Hall thrusters "magnetic shielding."

  8. Experimental and numerical analysis of pre-compressed masonry walls in two-way-bending with second order effects

    NASA Astrophysics Data System (ADS)

    Milani, Gabriele; Olivito, Renato S.; Tralli, Antonio

    2014-10-01

    The buckling behavior of slender unreinforced masonry (URM) walls subjected to axial compression and out-of-plane lateral loads is investigated through a combined experimental and numerical homogenizedapproach. After a preliminary analysis performed on a unit cell meshed by means of elastic FEs and non-linear interfaces, macroscopic moment-curvature diagrams so obtained are implemented at a structural level, discretizing masonry by means of rigid triangular elements and non-linear interfaces. The non-linear incremental response of the structure is accounted for a specific quadratic programming routine. In parallel, a wide experimental campaign is conducted on walls in two way bending, with the double aim of both validating the numerical model and investigating the behavior of walls that may not be reduced to simple cantilevers or simply supported beams. Panels investigated are dry-joint in scale square walls simply supported at the base and on a vertical edge, exhibiting the classical Rondelet's mechanism. The results obtained are compared with those provided by the numerical model.

  9. Full-thickness skin graft vs. synthetic mesh in the repair of giant incisional hernia: a randomized controlled multicenter study.

    PubMed

    Clay, L; Stark, B; Gunnarsson, U; Strigård, K

    2018-04-01

    Repair of large incisional hernias includes the implantation of a synthetic mesh, but this may lead to pain, stiffness, infection and enterocutaneous fistulae. Autologous full-thickness skin graft as on-lay reinforcement has been tested in eight high-risk patients in a proof-of-concept study, with satisfactory results. In this multicenter randomized study, the use of skin graft was compared to synthetic mesh in giant ventral hernia repair. Non-smoking patients with a ventral hernia > 10 cm wide were randomized to repair using an on-lay autologous full-thickness skin graft or a synthetic mesh. The primary endpoint was surgical site complications during the first 3 months. A secondary endpoint was patient comfort. Fifty-three patients were included. Clinical evaluation was performed at a 3-month follow-up appointment. There were fewer patients in the skin graft group reporting discomfort: 3 (13%) vs. 12 (43%) (p = 0.016). Skin graft patients had less pain and a better general improvement. No difference was seen regarding seroma; 13 (54%) vs. 13 (46%), or subcutaneous wound infection; 5 (20%) vs. 7 (25%). One recurrence appeared in each group. Three patients in the skin graft group and two in the synthetic mesh group were admitted to the intensive care unit. No difference was seen for the primary endpoint short-term surgical complication. Full-thickness skin graft appears to be a reliable material for ventral hernia repair producing no more complications than when using synthetic mesh. Patients repaired with a skin graft have less subjective abdominal wall symptoms.

  10. Electrochemical reduction of UO2 in LiCl-Li2O molten salt using porous and nonporous anode shrouds

    NASA Astrophysics Data System (ADS)

    Choi, Eun-Young; Won, Chan Yeon; Cha, Ju-Sun; Park, Wooshin; Im, Hun Suk; Hong, Sun-Seok; Hur, Jin-Mok

    2014-01-01

    Electrochemical reductions of uranium oxide in a molten LiCl-Li2O electrolyte were carried out using porous and nonporous anode shrouds. The study focused on the effect of the type of anode shroud on the current density by running experiments with six anode shrouds. Dense ceramics, MgO, and MgO (3 wt%) stabilized ZrO2 (ZrO2-MgO) were used as nonporous shrouds. STS 20, 100, and 300 meshes and ZrO2-MgO coated STS 40 mesh were used as porous shrouds. The current densities (0.34-0.40 A cm-2) of the electrolysis runs using the nonporous anode shrouds were much lower than those (0.76-0.79 A cm-2) of the runs using the porous shrouds. The ZrO2-MgO shroud (600-700 MPa at 25 °C) showed better bending strength than that of MgO (170 MPa at 25 °C). The high current densities achieved in the electrolysis runs using the porous anode shrouds were attributed to the transport of O2- ions through the pores in meshes of the shroud wall. ZrO2-MgO coating on STS mesh was chemically unstable in a molten LiCl-Li2O electrolyte containing Li metal. The electrochemical reduction runs using STS 20, 100, and 300 meshes showed similar current densities in spite of their different opening sizes. The STS mesh shrouds which were immersed in a LiCl-Li2O electrolyte were stable without any damage or corrosion.

  11. The Effectiveness of Shrouding on Reducing Meshed Spur Gear Power Loss - Test Results

    NASA Technical Reports Server (NTRS)

    Delgado, I. R.; Hurrell, M. J.

    2017-01-01

    Gearbox efficiency is reduced at high rotational speeds due to windage drag and viscous effects on rotating, meshed gear components. A goal of NASA aeronautics rotorcraft research is aimed at propulsion technologies that improve efficiency while minimizing vehicle weight. Specifically, reducing power losses to rotorcraft gearboxes would allow gains in areas such as vehicle payload, range, mission type, and fuel consumption. To that end, a gear windage rig has been commissioned at NASA Glenn Research Center to measure windage drag on gears and to test methodologies to mitigate windage power losses. One method used in rotorcraft gearbox design attempts to reduce gear windage power loss by utilizing close clearance walls to enclose the gears in both the axial and radial directions. The close clearance shrouds result in reduced drag on the gear teeth, and reduced power loss. For meshed spur gears, the shrouding takes the form of metal side plates and circumferential metal sectors. Variably positioned axial and radial shrouds are incorporated in the NASA rig to study the effect of shroud clearance on gearbox power loss. A number of researchers have given experimental and analytical results for single spur gears, with and without shrouding. Shrouded meshed spur gear test results are sparse in the literature. Windage tests were run at NASA Glenn using meshed spur gears at four shroud configurations: unshrouded, shrouded (max. axial, max radial), and two intermediate shrouding conditions. Results are compared to available meshed spur gear power loss data analyses as well as single spur gear data/analyses. Recommendations are made for future work.

  12. The Effectiveness of Shrouding on Reducing Meshed Spur Gear Power Loss Test Results

    NASA Technical Reports Server (NTRS)

    Delgado, I. R.; Hurrell, M. J.

    2017-01-01

    Gearbox efficiency is reduced at high rotational speeds due to windage drag and viscous effects on rotating, meshed gear components. A goal of NASA aeronautics rotorcraft research is aimed at propulsion technologies that improve efficiency while minimizing vehicle weight. Specifically, reducing power losses to rotorcraft gearboxes would allow gains in areas such as vehicle payload, range, mission type, and fuel consumption. To that end, a gear windage rig has been commissioned at NASA Glenn Research Center to measure windage drag on gears and to test methodologies to mitigate windage power losses. One method used in rotorcraft gearbox design attempts to reduce gear windage power loss by utilizing close clearance walls to enclose the gears in both the axial and radial directions. The close clearance shrouds result in reduced drag on the gear teeth and reduced power loss. For meshed spur gears, the shrouding takes the form of metal side plates and circumferential metal sectors. Variably positioned axial and radial shrouds are incorporated in the NASA rig to study the effect of shroud clearance on gearbox power loss. A number of researchers have given experimental and analytical results for single spur gears, with and without shrouding. Shrouded meshed spur gear test results are sparse in the literature. Windage tests were run at NASA Glenn using meshed spur gears at four shroud configurations: unshrouded, shrouded (max. axial, max. radial), and two intermediate shrouding conditions. Results are compared to available meshed spur gear power loss data analyses as well as single spur gear data analyses.

  13. Abdominal wall integrity after open abdomen: long-term results of vacuum-assisted wound closure and mesh-mediated fascial traction (VAWCM).

    PubMed

    Willms, A; Schaaf, S; Schwab, R; Richardsen, I; Bieler, D; Wagner, B; Güsgen, C

    2016-12-01

    The open abdomen has become a standard technique in the management of critically ill patients undergoing surgery for severe intra-abdominal conditions. Negative pressure and mesh-mediated fascial traction are commonly used and achieve low fistula rates and high fascial closure rates. In this study, long-term results of a standardised treatment approach are presented. Fifty-five patients who underwent OA management for different indications at our institution from 2006 to 2013 were enrolled. All patients were treated under a standardised algorithm that uses a combination of vacuum-assisted wound closure and mesh-mediated fascial traction. Structured follow-up assessments were offered to patients and included a medical history, a clinical examination and abdominal ultrasonography. The data obtained were statistically analysed. The fascial closure rate was 74 % in an intention-to-treat analysis and 89 % in a per-protocol analysis. The fistula rate was 1.8 %. Thirty-four patients attended follow-up. The median follow-up was 46 months (range 12-88 months). Incisional hernias developed in 35 %. Patients with hernias needed more operative procedures (10.3 vs 3.4, p = 0.03) than patients without hernia formation. A Patient Observer Scar Assessment Scale (POSAS) of 31.1 was calculated. Patients with symptomatic hernias (NAS of 2-10) had a significantly lower mean POSAS score (p = 0.04). Vacuum-assisted wound closure and mesh-mediated fascial traction (VAWCM) seem to result in low complication rates and high fascial closure rates. Abdominal wall reconstruction, which is a challenging and complex procedure and causes considerable patient discomfort, can thus be avoided in the majority of cases. Available results are based on studies involving only a small number of cases. Multi-centre studies and registry-based data are therefore needed to validate these findings.

  14. FacetModeller: Software for manual creation, manipulation and analysis of 3D surface-based models

    NASA Astrophysics Data System (ADS)

    Lelièvre, Peter G.; Carter-McAuslan, Angela E.; Dunham, Michael W.; Jones, Drew J.; Nalepa, Mariella; Squires, Chelsea L.; Tycholiz, Cassandra J.; Vallée, Marc A.; Farquharson, Colin G.

    2018-01-01

    The creation of 3D models is commonplace in many disciplines. Models are often built from a collection of tessellated surfaces. To apply numerical methods to such models it is often necessary to generate a mesh of space-filling elements that conforms to the model surfaces. While there are meshing algorithms that can do so, they place restrictive requirements on the surface-based models that are rarely met by existing 3D model building software. Hence, we have developed a Java application named FacetModeller, designed for efficient manual creation, modification and analysis of 3D surface-based models destined for use in numerical modelling.

  15. Fabrication of durable copper plating superhydrophobic surface with improved corrosion resistance and oil-water separation properties

    NASA Astrophysics Data System (ADS)

    Zhao, Yichao; Xiao, Xinyan; Ye, Zhihao; Ji, Qiang; Xie, Wei

    2018-02-01

    A mechanical durable superhydrophobic copper-plated stainless steel mesh was successfully fabricated by an electrodeposition process and 1-octadecanethiol modification. The as-prepared superhydrophobic mesh displays water contact angle of 153° and shows excellent anti-corrosion and water-oil separation properties in the condition of 0.1 A/cm2 current density for 35 s. In comparison with bare stainless steel mesh, the corrosion current of the as-prepared superhydrophobic mesh is close to 1/6 of the former. Meanwhile, the as-prepared superhydrophobic mesh could continuously separate oil from oil-water mixtures. The separation efficiency of continuous separation is as high as 96% and shows less than 1% decrease after ten cycles.

  16. User's guide to PMESH: A grid-generation program for single-rotation and counterrotation advanced turboprops

    NASA Technical Reports Server (NTRS)

    Warsi, Saif A.

    1989-01-01

    A detailed operating manual is presented for a grid generating program that produces 3-D meshes for advanced turboprops. The code uses both algebraic and elliptic partial differential equation methods to generate single rotation and counterrotation, H or C type meshes for the z - r planes and H type for the z - theta planes. The code allows easy specification of geometrical constraints (such as blade angle, location of bounding surfaces, etc.), mesh control parameters (point distribution near blades and nacelle, number of grid points desired, etc.), and it has good runtime diagnostics. An overview is provided of the mesh generation procedure, sample input dataset with detailed explanation of all input, and example meshes.

  17. Crowned spur gears - Methods for generation and Tooth Contact Analysis. II - Generation of the pinion tooth surface by a surface of revolution

    NASA Technical Reports Server (NTRS)

    Litvin, F. L.; Handschuh, R. F.; Zhang, J.

    1988-01-01

    A method for generation of crowned pinion tooth surfaces using a surface of revolution is developed. The crowned pinion meshes with a regular involute gear and has a prescribed parabolic type of transmission errors when the gears operate in the aligned mode. When the gears are misaligned the transmission error remains parabolic with the maximum level still remaining very small (less than 0.34 arc second for the numerical examples). Tooth Contact Analysis (TCA) is used to simulate the conditions of meshing, determine the transmission error, and the bearing contact.

  18. Photoinduced underwater superoleophobicity of TiO2 thin films.

    PubMed

    Sawai, Yusuke; Nishimoto, Shunsuke; Kameshima, Yoshikazu; Fujii, Eiji; Miyake, Michihiro

    2013-06-11

    The photoinduced wettabilities of water, n-hexadecane, dodecane, and n-heptane on a flat TiO2 surface prepared by a sol-gel method-based coating were investigated. An amphiphilic surface produced by UV irradiation exhibited underwater superoleophobicity with an extremely high static oil contact angle (CA) of over 160°. The TiO2 surface almost completely repelled the oil droplet in water. A robust TiO2 surface with no fragile nanomicrostructure was fabricated on a Ti mesh with a pore size of approximately 150 μm. The fabricated mesh was found to be applicable as an oil/water separation filter.

  19. SiSSR: Simultaneous subdivision surface registration for the quantification of cardiac function from computed tomography in canines.

    PubMed

    Vigneault, Davis M; Pourmorteza, Amir; Thomas, Marvin L; Bluemke, David A; Noble, J Alison

    2018-05-01

    Recent improvements in cardiac computed tomography (CCT) allow for whole-heart functional studies to be acquired at low radiation dose (<2mSv) and high-temporal resolution (<100ms) in a single heart beat. Although the extraction of regional functional information from these images is of great clinical interest, there is a paucity of research into the quantification of regional function from CCT, contrasting with the large body of work in echocardiography and cardiac MR. Here we present the Simultaneous Subdivision Surface Registration (SiSSR) method: a fast, semi-automated image analysis pipeline for quantifying regional function from contrast-enhanced CCT. For each of thirteen adult male canines, we construct an anatomical reference mesh representing the left ventricular (LV) endocardium, obviating the need for a template mesh to be manually sculpted and initialized. We treat this generated mesh as a Loop subdivision surface, and adapt a technique previously described in the context of 3-D echocardiography to register these surfaces to the endocardium efficiently across all cardiac frames simultaneously. Although previous work performs the registration at a single resolution, we observe that subdivision surfaces naturally suggest a multiresolution approach, leading to faster convergence and avoiding local minima. We additionally make two notable changes to the cost function of the optimization, explicitly encouraging plausible biological motion and high mesh quality. Finally, we calculate an accepted functional metric for CCT from the registered surfaces, and compare our results to an alternate state-of-the-art CCT method. Published by Elsevier B.V.

  20. Technique for Calculating Solution Derivatives With Respect to Geometry Parameters in a CFD Code

    NASA Technical Reports Server (NTRS)

    Mathur, Sanjay

    2011-01-01

    A solution has been developed to the challenges of computation of derivatives with respect to geometry, which is not straightforward because these are not typically direct inputs to the computational fluid dynamics (CFD) solver. To overcome these issues, a procedure has been devised that can be used without having access to the mesh generator, while still being applicable to all types of meshes. The basic approach is inspired by the mesh motion algorithms used to deform the interior mesh nodes in a smooth manner when the surface nodes, for example, are in a fluid structure interaction problem. The general idea is to model the mesh edges and nodes as constituting a spring-mass system. Changes to boundary node locations are propagated to interior nodes by allowing them to assume their new equilibrium positions, for instance, one where the forces on each node are in balance. The main advantage of the technique is that it is independent of the volumetric mesh generator, and can be applied to structured, unstructured, single- and multi-block meshes. It essentially reduces the problem down to defining the surface mesh node derivatives with respect to the geometry parameters of interest. For analytical geometries, this is quite straightforward. In the more general case, one would need to be able to interrogate the underlying parametric CAD (computer aided design) model and to evaluate the derivatives either analytically, or by a finite difference technique. Because the technique is based on a partial differential equation (PDE), it is applicable not only to forward mode problems (where derivatives of all the output quantities are computed with respect to a single input), but it could also be extended to the adjoint problem, either by using an analytical adjoint of the PDE or a discrete analog.

  1. Reducing Ice Adhesion on Nonsmooth Metallic Surfaces: Wettability and Topography Effects.

    PubMed

    Ling, Edwin Jee Yang; Uong, Victor; Renault-Crispo, Jean-Sébastien; Kietzig, Anne-Marie; Servio, Phillip

    2016-04-06

    The effects of ice formation and accretion on external surfaces range from being mildly annoying to potentially life-threatening. Ice-shedding materials, which lower the adhesion strength of ice to its surface, have recently received renewed research attention as a means to circumvent the problem of icing. In this work, we investigate how surface wettability and surface topography influence the ice adhesion strength on three different surfaces: (i) superhydrophobic laser-inscribed square pillars on copper, (ii) stainless steel 316 Dutch-weave meshes, and (iii) multiwalled carbon nanotube-covered steel meshes. The finest stainless steel mesh displayed the best performance with a 93% decrease in ice adhesion relative to polished stainless steel, while the superhydrophobic square pillars exhibited an increase in ice adhesion by up to 67% relative to polished copper. Comparisons of dynamic contact angles revealed little correlation between surface wettability and ice adhesion. On the other hand, by considering the ice formation process and the fracture mechanics at the ice-substrate interface, we found that two competing mechanisms governing ice adhesion strength arise on nonplanar surfaces: (i) mechanical interlocking of the ice within the surface features that enhances adhesion, and (ii) formation of microcracks that act as interfacial stress concentrators, which reduce adhesion. Our analysis provides insight toward new approaches for the design of ice-releasing materials through the use of surface topographies that promote interfacial crack propagation.

  2. Connectivity-based, all-hexahedral mesh generation method and apparatus

    DOEpatents

    Tautges, T.J.; Mitchell, S.A.; Blacker, T.D.; Murdoch, P.

    1998-06-16

    The present invention is a computer-based method and apparatus for constructing all-hexahedral finite element meshes for finite element analysis. The present invention begins with a three-dimensional geometry and an all-quadrilateral surface mesh, then constructs hexahedral element connectivity from the outer boundary inward, and then resolves invalid connectivity. The result of the present invention is a complete representation of hex mesh connectivity only; actual mesh node locations are determined later. The basic method of the present invention comprises the step of forming hexahedral elements by making crossings of entities referred to as ``whisker chords.`` This step, combined with a seaming operation in space, is shown to be sufficient for meshing simple block problems. Entities that appear when meshing more complex geometries, namely blind chords, merged sheets, and self-intersecting chords, are described. A method for detecting invalid connectivity in space, based on repeated edges, is also described, along with its application to various cases of invalid connectivity introduced and resolved by the method. 79 figs.

  3. Connectivity-based, all-hexahedral mesh generation method and apparatus

    DOEpatents

    Tautges, Timothy James; Mitchell, Scott A.; Blacker, Ted D.; Murdoch, Peter

    1998-01-01

    The present invention is a computer-based method and apparatus for constructing all-hexahedral finite element meshes for finite element analysis. The present invention begins with a three-dimensional geometry and an all-quadrilateral surface mesh, then constructs hexahedral element connectivity from the outer boundary inward, and then resolves invalid connectivity. The result of the present invention is a complete representation of hex mesh connectivity only; actual mesh node locations are determined later. The basic method of the present invention comprises the step of forming hexahedral elements by making crossings of entities referred to as "whisker chords." This step, combined with a seaming operation in space, is shown to be sufficient for meshing simple block problems. Entities that appear when meshing more complex geometries, namely blind chords, merged sheets, and self-intersecting chords, are described. A method for detecting invalid connectivity in space, based on repeated edges, is also described, along with its application to various cases of invalid connectivity introduced and resolved by the method.

  4. Revisiting the Least-squares Procedure for Gradient Reconstruction on Unstructured Meshes

    NASA Technical Reports Server (NTRS)

    Mavriplis, Dimitri J.; Thomas, James L. (Technical Monitor)

    2003-01-01

    The accuracy of the least-squares technique for gradient reconstruction on unstructured meshes is examined. While least-squares techniques produce accurate results on arbitrary isotropic unstructured meshes, serious difficulties exist for highly stretched meshes in the presence of surface curvature. In these situations, gradients are typically under-estimated by up to an order of magnitude. For vertex-based discretizations on triangular and quadrilateral meshes, and cell-centered discretizations on quadrilateral meshes, accuracy can be recovered using an inverse distance weighting in the least-squares construction. For cell-centered discretizations on triangles, both the unweighted and weighted least-squares constructions fail to provide suitable gradient estimates for highly stretched curved meshes. Good overall flow solution accuracy can be retained in spite of poor gradient estimates, due to the presence of flow alignment in exactly the same regions where the poor gradient accuracy is observed. However, the use of entropy fixes has the potential for generating large but subtle discretization errors.

  5. Analysis and computation of a least-squares method for consistent mesh tying

    DOE PAGES

    Day, David; Bochev, Pavel

    2007-07-10

    We report in the finite element method, a standard approach to mesh tying is to apply Lagrange multipliers. If the interface is curved, however, discretization generally leads to adjoining surfaces that do not coincide spatially. Straightforward Lagrange multiplier methods lead to discrete formulations failing a first-order patch test [T.A. Laursen, M.W. Heinstein, Consistent mesh-tying methods for topologically distinct discretized surfaces in non-linear solid mechanics, Internat. J. Numer. Methods Eng. 57 (2003) 1197–1242]. This paper presents a theoretical and computational study of a least-squares method for mesh tying [P. Bochev, D.M. Day, A least-squares method for consistent mesh tying, Internat. J.more » Numer. Anal. Modeling 4 (2007) 342–352], applied to the partial differential equation -∇ 2φ+αφ=f. We prove optimal convergence rates for domains represented as overlapping subdomains and show that the least-squares method passes a patch test of the order of the finite element space by construction. To apply the method to subdomain configurations with gaps and overlaps we use interface perturbations to eliminate the gaps. Finally, theoretical error estimates are illustrated by numerical experiments.« less

  6. Durable underwater superoleophobic PDDA/halloysite nanotubes decorated stainless steel mesh for efficient oil-water separation

    NASA Astrophysics Data System (ADS)

    Hou, Kun; Zeng, Yicheng; Zhou, Cailong; Chen, Jiahui; Wen, Xiufang; Xu, Shouping; Cheng, Jiang; Lin, Yingguang; Pi, Pihui

    2017-09-01

    A durable underwater superoleophobic mesh was conveniently prepared by layer-by-layer (LBL) assembly of poly (diallyldimethylammonium chloride) (PDDA) and halloysite nanotubes (HNTs) on a stainless steel mesh. The hierarchical structure and roughness of the PDDA/HNTs coating surface were controlled by adjusting the number of layer deposition cycles. When the PDDA/HNTs coating with 10 deposition cycles was decorated on the mesh with pore size of about 54 μm, the underwater superoleophobic mesh was obtained. The as-prepared underwater superoleophobic PDDA/HNTs decorated mesh exhibits outstanding oil-water separation performance with a separation efficiency of over 97% for various oil/water mixtures, which allowed water to pass through while repelled oil completely. In addition, the as-prepared decorated mesh still maintained high separation efficiency above 97% after repeated 20 separation times for hexane/water mixture or chloroform/water mixture. More importantly, the as-prepared decorated mesh is durable enough to resist chemical and mechanical challenges, such as strong alkaline, salt aqueous and sand abrasion. Therefore, the as-prepared decorated mesh has practical utility in oil-water separation due to its stable oil-water performance, remarkable chemical and mechanical durability and the facile and eco-friendly preparation process.

  7. Safety of Synthetic Glue Used for Laparoscopic Prolapse Treatment.

    PubMed

    Sarasa Castelló, Núria; Toth, Alexandra; Canis, Michel; Botchorishvilli, Revaz

    2017-12-29

    We detected mesh erosion and serious postoperative complications in 3 women after performing laparoscopic promontofixation (LPF) using glue for mesh fixation. Glue, largely used in hernia surgery repair, is proposed by some gynecologic surgeons because it saves time and is easier to use than traditional sutures. We report 3 cases of postoperative complications after LPF in which glue had been used and provide research in the published literature about the use of glue in LPF. A research of glue use in gynecology mesh fixation was performed through PubMed on October 2016. The search was done using the Medical Subject Heading terms "POP" & "Laparoscopy" & "surgical Mesh" and the word either "glue" or "adhesive. Only 2 articles were found: Willecocq et al [1] and Estrade et al [2]. Neither study focused on postoperative complications. In this publication, we accurately edited video surgeries with an instructive purpose. University Hospital of Clermont-Ferrand, France. Patient A, a 65-year-old woman, complained of pelvic pain and vaginal discharge 1 month after LPF (polypropylene mesh and glue had been used). Wall mesh exposure and purulent discharge were noted. She received antibiotics and underwent mesh ablation surgery; debris of the glue was easily identified. Patient B, a 65-year-old lady with previous hysterectomy consulted for a bulging feeling in her vagina (classification: cystocele +2; rectocele +3 stage). An LPF was performed using polypropylene soft nonabsorbable mesh and glue. One month later, an apical defect of vaginal epithelialization was detected; she received long estrogenic local treatment but had to undergo surgery when presenting malodorous discharge and mesh exposure. The exposed mesh was removed, and pieces of glue were identified, having avoided mesh attachment. Patient C had a previous abdominal hysterectomy and promontofixation using a polyester mesh with glue. She consulted to us for vaginal mesh erosion covered with purulent discharge 3.5 years after LPF in another center. At the surgery, 1 cm of the prosthesis was identified in the vagina, dissected, and sutured. One year later, she consulted for dyspareunia and purulent discharge; vaginal rigid mesh exposure with an epithelization defect and inflammatory signs was seen. During laparoscopy, prosthetic exposition and glue debris on the prosthesis were identified. In all 3 cases, debris of glue were identified in the no integrated mesh area. The suggested reasons of exposure can be the excessive amount of surgical glue applied. Moreover, a large amount of glue may be impairing tissue ingrowth through the mesh pores, causing low fibrosis and poor tissue integration [3]. Glue seems to prevent fibrosis from occurring. Its use in pelvic organ prolapse laparoscopic mesh fixation should be done with caution. No prospective studies reporting long-term comorbidities and results have been published. Copyright © 2017 American Association of Gynecologic Laparoscopists. Published by Elsevier Inc. All rights reserved.

  8. Effect of ground control mesh on dust sampling and explosion mitigation.

    PubMed

    Alexander, D W; Chasko, L L

    2015-07-01

    Researchers from the National Institute for Occupational Safety and Health's Office of Mine Safety and Health Research conducted an assessment of the effects that ground control mesh might have on rock and float coal dust distribution in a coal mine. The increased use of mesh to control roof and rib spall introduces additional elevated surfaces on which rock or coal dust can collect. It is possible to increase the potential for dust explosion propagation if any float coal dust is not adequately inerted. In addition, the mesh may interfere with the collection of representative dust samples when using the pan-and-brush sampling method developed by the U.S. Bureau of Mines and used by the Mine Safety and Health Administration for band sampling. This study estimates the additional coal or rock dust that could accumulate on mesh and develops a means to collect representative dust samples from meshed entries.

  9. Effect of ground control mesh on dust sampling and explosion mitigation

    PubMed Central

    Alexander, D.W.; Chasko, L.L.

    2017-01-01

    Researchers from the National Institute for Occupational Safety and Health’s Office of Mine Safety and Health Research conducted an assessment of the effects that ground control mesh might have on rock and float coal dust distribution in a coal mine. The increased use of mesh to control roof and rib spall introduces additional elevated surfaces on which rock or coal dust can collect. It is possible to increase the potential for dust explosion propagation if any float coal dust is not adequately inerted. In addition, the mesh may interfere with the collection of representative dust samples when using the pan-and-brush sampling method developed by the U.S. Bureau of Mines and used by the Mine Safety and Health Administration for band sampling. This study estimates the additional coal or rock dust that could accumulate on mesh and develops a means to collect representative dust samples from meshed entries. PMID:28936000

  10. Minimally Invasive Component Separation Results in Fewer Wound-Healing Complications than Open Component Separation for Large Ventral Hernia Repairs

    PubMed Central

    Ghali, Shadi; Turza, Kristin C; Baumann, Donald P; Butler, Charles E

    2014-01-01

    BACKGROUND Minimally invasive component separation (CS) with inlay bioprosthetic mesh (MICSIB) is a recently developed technique for abdominal wall reconstruction that preserves the rectus abdominis perforators and minimizes subcutaneous dead space using limited-access tunneled incisions. We hypothesized that MICSIB would result in better surgical outcomes than would conventional open CS. STUDY DESIGN All consecutive patients who underwent CS (open or minimally invasive) with inlay bioprosthetic mesh for ventral hernia repair from 2005 to 2010 were included in a retrospective analysis of prospectively collected data. Surgical outcomes including wound-healing complications, hernia recurrences, and abdominal bulge/laxity rates were compared between patient groups based on the type of CS repair: MICSIB or open. RESULTS Fifty-seven patients who underwent MICSIB and 50 who underwent open CS were included. The mean follow-ups were 15.2±7.7 months and 20.7±14.3 months, respectively. The mean fascial defect size was significantly larger in the MICSIB group (405.4±193.6 cm2 vs. 273.8±186.8 cm2; p =0.002). The incidences of skin dehiscence (11% vs. 28%; p=0.011), all wound-healing complications (14% vs. 32%; p=0.026), abdominal wall laxity/bulge (4% vs. 14%; p=0.056), and hernia recurrence (4% vs. 8%; p=0.3) were lower in the MICSIB group than in the open CS group. CONCLUSIONS MICSIB resulted in fewer wound-healing complications than did open CS used for complex abdominal wall reconstructions. These findings are likely attributable to the preservation of paramedian skin vascularity and reduction in subcutaneous dead space with MICSIB. MICSIB should be considered for complex abdominal wall reconstructions, particularly in patients at increased risk of wound-healing complications. PMID:22521439

  11. The effect of screening doors and windows on indoor density of Anopheles arabiensis in south-west Ethiopia: a randomized trial

    PubMed Central

    2013-01-01

    Background Screening of houses might have impact on density of indoor host-seeking Anopheles mosquitoes. A randomized trial of screening windows and doors with metal mesh, and closing openings on eves and walls by mud was conducted to assess if reduce indoor densities of biting mosquitoes. Methods Mosquitoes were collected in forty houses using Centers for Diseases Control and Prevention (CDC) light traps biweekly in March and April 2011. A randomization of houses into control and intervention groups was done based on the baseline data. Windows and doors of 20 houses were screened by metal mesh, and openings on the walls and eves closed by mud and the rest 20 houses were used as control group. Mosquitoes were collected biweekly in October and November 2011 from both control and intervention houses. A Generalized Estimating Equations (GEE) with a negative binomial error distribution was used to account for over dispersion of Anopheles arabiensis and culicine counts and repeated catches made in the same house. Results Screening doors and windows, and closing openings on eves and wall by mud reduced the overall indoor densities of An. arabiensis by 40%. The effect of screenings pronounced on unfed An. arabiensis by resulting 42% reduction in houses with interventions. The total costs for screening windows and doors, and to close openings on the eves and walls by mud was 7.34 USD per house. Conclusion Screening houses reduced indoor density of An. arabiensis, and it was cheap and can easily incorporated into malaria vector strategies by local communities, but improving doors and windows fitness for screening should be considered during house construction to increase the efficacy of screenings. PMID:24028542

  12. The effect of screening doors and windows on indoor density of Anopheles arabiensis in south-west Ethiopia: a randomized trial.

    PubMed

    Massebo, Fekadu; Lindtjørn, Bernt

    2013-09-12

    Screening of houses might have impact on density of indoor host-seeking Anopheles mosquitoes. A randomized trial of screening windows and doors with metal mesh, and closing openings on eves and walls by mud was conducted to assess if reduce indoor densities of biting mosquitoes. Mosquitoes were collected in forty houses using Centers for Diseases Control and Prevention (CDC) light traps biweekly in March and April 2011. A randomization of houses into control and intervention groups was done based on the baseline data. Windows and doors of 20 houses were screened by metal mesh, and openings on the walls and eves closed by mud and the rest 20 houses were used as control group. Mosquitoes were collected biweekly in October and November 2011 from both control and intervention houses. A Generalized Estimating Equations (GEE) with a negative binomial error distribution was used to account for over dispersion of Anopheles arabiensis and culicine counts and repeated catches made in the same house. Screening doors and windows, and closing openings on eves and wall by mud reduced the overall indoor densities of An. arabiensis by 40%. The effect of screenings pronounced on unfed An. arabiensis by resulting 42% reduction in houses with interventions. The total costs for screening windows and doors, and to close openings on the eves and walls by mud was 7.34 USD per house. Screening houses reduced indoor density of An. arabiensis, and it was cheap and can easily incorporated into malaria vector strategies by local communities, but improving doors and windows fitness for screening should be considered during house construction to increase the efficacy of screenings.

  13. Discrete exterior calculus discretization of incompressible Navier-Stokes equations over surface simplicial meshes

    NASA Astrophysics Data System (ADS)

    Mohamed, Mamdouh S.; Hirani, Anil N.; Samtaney, Ravi

    2016-05-01

    A conservative discretization of incompressible Navier-Stokes equations is developed based on discrete exterior calculus (DEC). A distinguishing feature of our method is the use of an algebraic discretization of the interior product operator and a combinatorial discretization of the wedge product. The governing equations are first rewritten using the exterior calculus notation, replacing vector calculus differential operators by the exterior derivative, Hodge star and wedge product operators. The discretization is then carried out by substituting with the corresponding discrete operators based on the DEC framework. Numerical experiments for flows over surfaces reveal a second order accuracy for the developed scheme when using structured-triangular meshes, and first order accuracy for otherwise unstructured meshes. By construction, the method is conservative in that both mass and vorticity are conserved up to machine precision. The relative error in kinetic energy for inviscid flow test cases converges in a second order fashion with both the mesh size and the time step.

  14. A method to generate conformal finite-element meshes from 3D measurements of microstructurally small fatigue-crack propagation [A method to generate conformal finite-element meshes from 3D measurements of microstructurally small fatigue-crack propagation: 3D Meshes of Microstructurally Small Crack Growth

    DOE PAGES

    Spear, Ashley D.; Hochhalter, Jacob D.; Cerrone, Albert R.; ...

    2016-04-27

    In an effort to reproduce computationally the observed evolution of microstructurally small fatigue cracks (MSFCs), a method is presented for generating conformal, finite-element (FE), volume meshes from 3D measurements of MSFC propagation. The resulting volume meshes contain traction-free surfaces that conform to incrementally measured 3D crack shapes. Grain morphologies measured using near-field high-energy X-ray diffraction microscopy are also represented within the FE volume meshes. Proof-of-concept simulations are performed to demonstrate the utility of the mesh-generation method. The proof-of-concept simulations employ a crystal-plasticity constitutive model and are performed using the conformal FE meshes corresponding to successive crack-growth increments. Although the simulationsmore » for each crack increment are currently independent of one another, they need not be, and transfer of material-state information among successive crack-increment meshes is discussed. The mesh-generation method was developed using post-mortem measurements, yet it is general enough that it can be applied to in-situ measurements of 3D MSFC propagation.« less

  15. A method to generate conformal finite-element meshes from 3D measurements of microstructurally small fatigue-crack propagation [A method to generate conformal finite-element meshes from 3D measurements of microstructurally small fatigue-crack propagation: 3D Meshes of Microstructurally Small Crack Growth

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spear, Ashley D.; Hochhalter, Jacob D.; Cerrone, Albert R.

    In an effort to reproduce computationally the observed evolution of microstructurally small fatigue cracks (MSFCs), a method is presented for generating conformal, finite-element (FE), volume meshes from 3D measurements of MSFC propagation. The resulting volume meshes contain traction-free surfaces that conform to incrementally measured 3D crack shapes. Grain morphologies measured using near-field high-energy X-ray diffraction microscopy are also represented within the FE volume meshes. Proof-of-concept simulations are performed to demonstrate the utility of the mesh-generation method. The proof-of-concept simulations employ a crystal-plasticity constitutive model and are performed using the conformal FE meshes corresponding to successive crack-growth increments. Although the simulationsmore » for each crack increment are currently independent of one another, they need not be, and transfer of material-state information among successive crack-increment meshes is discussed. The mesh-generation method was developed using post-mortem measurements, yet it is general enough that it can be applied to in-situ measurements of 3D MSFC propagation.« less

  16. Laparoscopic treatment of incisional and primary ventral hernia in morbidly obese patients with a BMI over 35.

    PubMed

    Marx, L; Raharimanantsoa, M; Mandala, S; D'Urso, A; Vix, M; Mutter, D

    2014-12-01

    Incisional and ventral hernias are common surgical indications. Their management is associated with significant complications and recurrences in open surgery (15-25%). Since laparoscopy has become a standard in bariatric surgery, there has been a natural trend to treat obese patients with parietal wall defects laparoscopically. The aim of our study was to evaluate the feasibility and the results of the laparoscopic management of parietal wall defects in patients with a BMI >35. A series of 79 patients were included. Data were acquired prospectively and analyzed retrospectively. The surgical procedure was standardized: 3 ports, mesh type (Parietex™ Composite mesh, Covidien, France), fixation with non-absorbable transfascial sutures, and tackers. Complications were evaluated. Out of 79 patients (29 men, 50 women), 43 had umbilical and 36 had ventral hernias. Mean age was 52.4 years, and mean BMI was 40.83 kg/m(2). Mean postoperative hospital stay was 2 days. Postoperative pain evaluated by visual analog scale was 2.86. No intraoperative complications or deaths occurred. Seven postoperative complications occurred (8.86%): two parietal wall hematomas treated by radiological embolization, two significant cases of postoperative pain, one postoperative obstruction, one spontaneously resolved respiratory failure, and one early (day 1) parietal wall defect with immediate reoperation. Postoperative seroma rate was 26.58% (21 patients, all of whom were treated conservatively). Postoperative follow-up was 18.10 months (1-84 months), and recurrence rate was 3.8% (3 patients). This study confirms the feasibility and safety of the laparoscopic approach for ventral hernias in morbidly obese patients. Recurrence rates (3.8%) appeared lower than the ones observed in the literature (15-25%). Postoperative hemorrhage and port-site hernia are specific complications of this approach. Postoperative hospital stay is low (2 days) as compared to open surgery. Laparoscopic management of parietal wall defects should be considered a standard option in morbidly obese patients.

  17. Osseointegrated dental implants produced via microwave processing

    NASA Astrophysics Data System (ADS)

    Kutty, Muralithran G.

    This research is a comprehensive effort to develop osseointegrated dental implants via microwave processing. A net-shape microwave sintering procedure was employed to fabricate dental implants. Commercial pure titanium powders (-100, -200 and -325 mesh sizes) were used in this work. This process eliminates the need for machining of implants and prevents contamination. The idea was to take advantage of the peculiar way microwave couple with metallic powders, i.e. generating heat in the interior of the sample and dissipating it away through the surface. The desired features for an implant, a dense core with surface pores, is not possible via conventional sintering. Coating with hydroxyapatite via electrodeposition and chemical combustion vapor deposition was also attempted to further enhance the bioactivity of this layer. Surface roughness and area were measured using a non-contact surface profilometer to further describe the unique surface. In-vitro studies, conducted using osteoblast cells extracted from neonatal rat calvarial, showed improved cell growth on all the uncoated porous samples. However, the highest cell growth was observed on the -200 mesh size samples. The higher surface area of the -200 mesh samples is attributed to this observation. This work was able to identify the processing parameters for titanium in microwave and establishes the importance of surface area as a key parameter for cell growth on porous surfaces as compared to surface roughness.

  18. Tangle-Free Mesh Motion for Ablation Simulations

    NASA Technical Reports Server (NTRS)

    Droba, Justin

    2016-01-01

    Problems involving mesh motion-which should not be mistakenly associated with moving mesh methods, a class of adaptive mesh redistribution techniques-are of critical importance in numerical simulations of the thermal response of melting and ablative materials. Ablation is the process by which material vaporizes or otherwise erodes due to strong heating. Accurate modeling of such materials is of the utmost importance in design of passive thermal protection systems ("heatshields") for spacecraft, the layer of the vehicle that ensures survival of crew and craft during re-entry. In an explicit mesh motion approach, a complete thermal solve is first performed. Afterwards, the thermal response is used to determine surface recession rates. These values are then used to generate boundary conditions for an a posteriori correction designed to update the location of the mesh nodes. Most often, linear elastic or biharmonic equations are used to model this material response, traditionally in a finite element framework so that complex geometries can be simulated. A simple scheme for moving the boundary nodes involves receding along the surface normals. However, for all but the simplest problem geometries, evolution in time following such a scheme will eventually bring the mesh to intersect and "tangle" with itself, inducing failure. This presentation demonstrates a comprehensive and sophisticated scheme that analyzes the local geometry of each node with help from user-provided clues to eliminate the tangle and enable simulations on a wide-class of difficult problem geometries. The method developed is demonstrated for linear elastic equations but is general enough that it may be adapted to other modeling equations. The presentation will explicate the inner workings of the tangle-free mesh motion algorithm for both two and three-dimensional meshes. It will show abstract examples of the method's success, including a verification problem that demonstrates its accuracy and correctness. The focus of the presentation will be on the algorithm; specifics on how the techniques may be used in spacecraft design will be not discussed.

  19. A method for semi-automatic segmentation and evaluation of intracranial aneurysms in bone-subtraction computed tomography angiography (BSCTA) images

    NASA Astrophysics Data System (ADS)

    Krämer, Susanne; Ditt, Hendrik; Biermann, Christina; Lell, Michael; Keller, Jörg

    2009-02-01

    The rupture of an intracranial aneurysm has dramatic consequences for the patient. Hence early detection of unruptured aneurysms is of paramount importance. Bone-subtraction computed tomography angiography (BSCTA) has proven to be a powerful tool for detection of aneurysms in particular those located close to the skull base. Most aneurysms though are chance findings in BSCTA scans performed for other reasons. Therefore it is highly desirable to have techniques operating on standard BSCTA scans available which assist radiologists and surgeons in evaluation of intracranial aneurysms. In this paper we present a semi-automatic method for segmentation and assessment of intracranial aneurysms. The only user-interaction required is placement of a marker into the vascular malformation. Termination ensues automatically as soon as the segmentation reaches the vessels which feed the aneurysm. The algorithm is derived from an adaptive region-growing which employs a growth gradient as criterion for termination. Based on this segmentation values of high clinical and prognostic significance, such as volume, minimum and maximum diameter as well as surface of the aneurysm, are calculated automatically. the segmentation itself as well as the calculated diameters are visualised. Further segmentation of the adjoining vessels provides the means for visualisation of the topographical situation of vascular structures associated to the aneurysm. A stereolithographic mesh (STL) can be derived from the surface of the segmented volume. STL together with parameters like the resiliency of vascular wall tissue provide for an accurate wall model of the aneurysm and its associated vascular structures. Consequently the haemodynamic situation in the aneurysm itself and close to it can be assessed by flow modelling. Significant values of haemodynamics such as pressure onto the vascular wall, wall shear stress or pathlines of the blood flow can be computed. Additionally a dynamic flow model can be generated. Thus the presented method supports a better understanding of the clinical situation and assists the evaluation of therapeutic options. Furthermore it contributes to future research addressing intervention planning and prognostic assessment of intracranial aneurysms.

  20. Electrical burns of the abdomen.

    PubMed

    Srivastava, Rakesh Kumar; Kumar, Ritesh

    2013-09-01

    A 35-year-old male farmer came in contact with 11,000 volts high tension electric wire and sustained full thickness burn wounds over scapula, upper limb and anterior abdominal wall along with perforation of the intestine. Patient was initially managed conservatively in general surgery ward and was referred to us after 3 days with necrosis of the burned skin and muscles over the shoulder and abdomen. Patient was initially managed conservatively and then thorough debridement of the necrotic skin over the left shoulder and upper arm was done and the area was split skin grafted. Patient developed enterocutaneous fistula, which healed over a period of 8 weeks. The granulating wound over the abdomen was also skin grafted and patient was discharged after 18 days. About 4 months, after the discharge patient presented with ventral hernia. Repair of ventral hernia by synthetic mesh application and reconstruction of the abdominal wall with a free tensor fascia lata flap was done over the mesh, but the flap failed. Then after debridement two random pattern transposition skin flaps, one from the right upper and another from the left lower abdomen were transposed over the abdominal wound and donor area was skin grafted. Patient was discharged after 17 days.

  1. Glottis effects on the cough clearance process simulated with a CFD dynamic mesh and Eulerian wall film model.

    PubMed

    Paz, Concepción; Suárez, Eduardo; Parga, Oscar; Vence, Jesús

    2017-09-01

    In this study, we have reproduced the cough clearance process with an Eulerian wall film model. The simulated domain is based on realistic geometry from the literature, which has been improved by adding the glottis and epiglottis. The vocal fold movement has been included due to the dynamic mesh method, considering different abduction and adduction angles and velocities. The proposed methodology captures the deformation of the flexible tissue, considers non-Newtonian properties for the mucus, and enables us to reproduce a single cough or a cough epoch. The cough efficiency (CE) has been used to quantify the overall performance of the cough, considering many different boundary conditions, for the analysis of the glottis effect. It was observed that a viscous shear force is the main mechanism in the cough clearance process, while the glottis closure time and the epiglottis position do not have a significant effect on the CE. The cough assistance devices improve the CE, and the enhancement rate grows logarithmically with the operating pressure. The cough can achieve an effective mucus clearance process, even with a fixed glottis. Nevertheless, the glottis closure substantially improves the CE results.

  2. Silk fibroin hydrogel as physical barrier for prevention of post hernia adhesion.

    PubMed

    Konar, S; Guha, R; Kundu, B; Nandi, S; Ghosh, T K; Kundu, S C; Konar, A; Hazra, S

    2017-02-01

    Adhesion formation remains a major complication following hernia repair surgery. Physical barriers though effective for adhesion prevention in clinical settings are associated with major disadvantages, therefore, needs further investigation. This study evaluates silk fibroin hydrogel as a physical barrier on polypropylene mesh for the prevention of adhesion following ventral hernia repair. Peritoneal explants were cultured on silk fibroin scaffold to evaluate its support for mesothelial cell growth. Full thickness uniform sized defects were created on the ventral abdominal wall of rabbits, and the defects were covered either with silk hydrogel coated polypropylene mesh or with plain polypropylene mesh as a control. The animals were killed after 1 month, and the adhesion formation was graded; healing response of peritoneum was evaluated by immunohistochemistry with calretinin, collagen staining of peritoneal sections, and expression of PCNA, collagen-I, TNFα, IL6 by real time PCR; and its adverse effect if any was determined. Silk fibroin scaffold showed excellent support for peritoneal cell growth in vitro and the cells expressed calretinin. A remarkable prevention of adhesion formation was observed in the animals implanted with silk hydrogel coated mesh compared to the control group; in these animals peritoneal healing was complete and predominantly by mesothelial cells with minimum fibrotic changes. Expression of inflammatory cytokines decreased compared to control animals, histology of abdominal organs, haematological and blood biochemical parameters remained normal. Therefore, silk hydrogel coating of polypropylene mesh can improve peritoneal healing, minimize adhesion formation, is safe and can augment the outcome of hernia surgery.

  3. An efficient two-stage approach for image-based FSI analysis of atherosclerotic arteries

    PubMed Central

    Rayz, Vitaliy L.; Mofrad, Mohammad R. K.; Saloner, David

    2010-01-01

    Patient-specific biomechanical modeling of atherosclerotic arteries has the potential to aid clinicians in characterizing lesions and determining optimal treatment plans. To attain high levels of accuracy, recent models use medical imaging data to determine plaque component boundaries in three dimensions, and fluid–structure interaction is used to capture mechanical loading of the diseased vessel. As the plaque components and vessel wall are often highly complex in shape, constructing a suitable structured computational mesh is very challenging and can require a great deal of time. Models based on unstructured computational meshes require relatively less time to construct and are capable of accurately representing plaque components in three dimensions. These models unfortunately require additional computational resources and computing time for accurate and meaningful results. A two-stage modeling strategy based on unstructured computational meshes is proposed to achieve a reasonable balance between meshing difficulty and computational resource and time demand. In this method, a coarsegrained simulation of the full arterial domain is used to guide and constrain a fine-scale simulation of a smaller region of interest within the full domain. Results for a patient-specific carotid bifurcation model demonstrate that the two-stage approach can afford a large savings in both time for mesh generation and time and resources needed for computation. The effects of solid and fluid domain truncation were explored, and were shown to minimally affect accuracy of the stress fields predicted with the two-stage approach. PMID:19756798

  4. Applying Parallel Adaptive Methods with GeoFEST/PYRAMID to Simulate Earth Surface Crustal Dynamics

    NASA Technical Reports Server (NTRS)

    Norton, Charles D.; Lyzenga, Greg; Parker, Jay; Glasscoe, Margaret; Donnellan, Andrea; Li, Peggy

    2006-01-01

    This viewgraph presentation reviews the use Adaptive Mesh Refinement (AMR) in simulating the Crustal Dynamics of Earth's Surface. AMR simultaneously improves solution quality, time to solution, and computer memory requirements when compared to generating/running on a globally fine mesh. The use of AMR in simulating the dynamics of the Earth's Surface is spurred by future proposed NASA missions, such as InSAR for Earth surface deformation and other measurements. These missions will require support for large-scale adaptive numerical methods using AMR to model observations. AMR was chosen because it has been successful in computation fluid dynamics for predictive simulation of complex flows around complex structures.

  5. Flank and Lumbar Hernia Repair.

    PubMed

    Beffa, Lucas R; Margiotta, Alyssa L; Carbonell, Alfredo M

    2018-06-01

    Flank and lumbar hernias are challenging because of their rarity and anatomic location. Several challenges exist when approaching these specific abdominal wall defects, including location, innervation of the lateral abdominal wall musculature, and their proximity to bony landmarks. These hernias are confined by the costal margin, spine, and pelvic brim, which makes closure of the defect, including mesh placement, difficult. This article discusses the anatomy of lumbar and flank hernias, the various etiologies for these hernias, and the procedural steps for open and robotic preperitoneal approaches. The available clinical evidence regarding outcomes for various repair techniques is also reviewed. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Plastic mechanism of multi-pass double-roller clamping spinning for arc-shaped surface flange

    NASA Astrophysics Data System (ADS)

    Fan, Shuqin; Zhao, Shengdun; Zhang, Qi; Li, Yongyi

    2013-11-01

    Compared with the conventional single-roller spinning process, the double-roller clamping spinning(DRCS) process can effectively prevent the sheet metal surface wrinkling and improve the the production efficiency and the shape precision of final spun part. Based on ABAQUS/Explicit nonlinear finite element software, the finite element model of the multi-pass DRCS for the sheet metal is established, and the material model, the contact definition, the mesh generation, the loading trajectory and other key technical problems are solved. The simulations on the multi-pass DRCS of the ordinary Q235A steel cylindrical part with the arc-shaped surface flange are carried out. The effects of number of spinning passes on the production efficiency, the spinning moment, the shape error of the workpiece, and the wall thickness distribution of the final part are obtained. It is indicated definitely that with the increase of the number of spinning passes the geometrical precision of the spun part increases while the production efficiency reduces. Moreover, the variations of the spinning forces and the distributions of the stresses, strains, wall thickness during the multi-pass DRCS process are revealed. It is indicated that during the DRCS process the radical force is the largest, and the whole deformation area shows the tangential tensile strain and the radial compressive strain, while the thickness strain changes along the generatrix directions from the compressive strain on the outer edge of the flange to the tensile strain on the inner edge of the flange. Based on the G-CNC6135 NC lathe, the three-axis linkage computer-controlled experimental device for DRCS which is driven by the AC servo motor is developed. And then using the experimental device, the Q235A cylindrical parts with the arc-shape surface flange are formed by the DRCS. The simulation results of spun parts have good consistency with the experimental results, which verifies the feasibility of DRCS process and the reliability of the finite element model for DRCS.

  7. Boundary Recovery For Delaunay Tetrahedral Meshes Using Local Topological Transformations

    PubMed Central

    Ghadyani, Hamid; Sullivan, John; Wu, Ziji

    2009-01-01

    Numerous high-quality, volume mesh-generation systems exist. However, no strategy can address all geometry situations without some element qualities being compromised. Many 3D mesh generation algorithms are based on Delaunay tetrahedralization which frequently fails to preserve the input boundary surface topology. For biomedical applications, this surface preservation can be critical as they usually contain multiple material regions of interest coherently connected. In this paper we present an algorithm as a post-processing method that optimizes local regions of compromised element quality and recovers the original boundary surface facets (triangles) regardless of the original mesh generation strategy. The algorithm carves out a small sub-volume in the vicinity of the missing boundary facet or compromised element, creating a cavity. If the task is to recover a surface boundary facet, a natural exit hole in the cavity will be present. This hole is patched with the missing boundary surface face first followed by other patches to seal the cavity. If the task was to improve a compromised region, then the cavity is already sealed. Every triangular facet of the cavity shell is classified as an active face and can be connected to another shell node creating a tetrahedron. In the process the base of the tetrahedron is removed from the active face list and potentially 3 new active faces are created. This methodology is the underpinnings of our last resort method. Each active face can be viewed as the trunk of a tree. An exhaustive breath and depth search will identify all possible tetrahedral combinations to uniquely fill the cavity. We have streamlined this recursive process reducing the time complexity by orders of magnitude. The original surfaces boundaries (internal and external) are fully restored and the quality of compromised regions improved. PMID:20305743

  8. A new design concept for knitted external vein-graft support mesh.

    PubMed

    Singh, Charanpreet; Wang, Xungai

    2015-08-01

    Autologous vein-graft failure significantly limits the long-term efficacy of coronary artery bypass procedures. The major cause behind this complication is biomechanical mismatch between the vein and coronary artery. The implanted vein experiences a sudden increase (10-12 fold) in luminal pressures. The resulting vein over-distension or 'ballooning' initiates wall thickening phenomenon and ultimate occlusion. Therefore, a primary goal in improving the longevity of a coronary bypass procedure is to inhibit vein over-distension using mechanical constriction. The idea of using an external vein-graft support mesh has demonstrated sustained benefits and wide acceptance in experimental studies. Nitinol based knitted structures have offered more promising mechanical features than other mesh designs owing to their unique loosely looped construction. However, the conventional plain knit construction still exhibits limitations (radial compliance, deployment ease, flexibility, and bending stresses) which limit this design from proving its real clinical advantage. The new knitted mesh design presented in this study is based on the concept of composite knitting utilising high modulus (nitinol and polyester) and low modulus (polyurethane) material components. The experimental comparison of the new design with a plain knit design demonstrated significant improvement in biomechanical (compliance, flexibility, extensibility, viscoelasticity) and procedural (deployment limit) parameters. The results are indicative of the promising role of new mesh in restoring the lost compliance and pulsatility of vein-graft at high arterial pressures. This way it can assist in controlled vein-graft remodelling and stepwise restoration of vein mechanical homoeostasis. Also, improvement in deployment limit parameter offers more flexibility for a surgeon to use a wide range of vein diameters, which may otherwise be rendered unusable for a plain knit mesh. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Biaxial analysis of synthetic scaffolds for hernia repair demonstrates variability in mechanical anisotropy, non-linearity and hysteresis.

    PubMed

    Deeken, Corey R; Thompson, Dominic M; Castile, Ryan M; Lake, Spencer P

    2014-10-01

    Over the past 60 years, the soft tissue repair market has grown to include over 50 types of hernia repair materials. Surgeons typically implant these materials in the orientation that provides maximum overlap of the mesh over the defect, with little regard for mechanical properties of the mesh material. If the characteristics of the meshes were better understood, an appropriate material could be identified for each patient, and meshes could be placed to optimize integration with neighboring tissue and avoid the mechanical mis-match that can lead to impaired graft fixation. The purpose of this study was to fully characterize and compare the mechanical properties of thirteen types of hernia repair materials via planar biaxial tensile testing. Equibiaxial (i.e., equal simultaneous loading in both directions) and strip biaxial (i.e., loading in one direction with the other direction held fixed) tests were utilized as physiologically relevant loading regimes. After applying a 0.1N pre-load on each arm, samples were subjected to equibiaxial cyclic loading using a triangular waveform to 2.5mm displacement on each arm at 0.1Hz for 10 cycles. Samples were then subjected to two strip biaxial tests (using the same cyclic loading protocol), where extension was applied along a single axis with the other axis held fixed. The thirteen evaluated mesh types exhibited a wide range of mechanical properties. Some were nearly isotropic (C-QUR™, DUALMESH(®), PHYSIOMESH™, and PROCEED(®)), while others were highly anisotropic (Ventralight™ ST, Bard™ Mesh, and Bard™ Soft Mesh). Some displayed nearly linear behavior (Bard™ Mesh), while others were non-linear with a long toe region followed by a sharp rise in tension (INFINIT(®)). These materials are currently utilized in clinical settings as if they are uniform and interchangeable, and clearly this is not the case. The mechanical properties most advantageous for successful hernia repairs are currently only vaguely described in the clinical literature. The characteristics of the human abdominal wall must be extensively characterized to provide a thorough understanding of the tissue being reinforced/replaced by these meshes. A better understanding of these mechanical differences would enable matching of patient characteristics to a specific mesh with the properties best suited to that particular repair. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. SPH Simulation of Impact of a Surge on a Wall

    NASA Astrophysics Data System (ADS)

    Diwakar, Manoj Kumar; Mohapatra, Pranab Kumar; Tripathi, Shivam

    2014-05-01

    Structures located on the downstream of a dam are prone to impact of the surge due to dam break flow. Ramsden (1996) experimentally studied the run-up height on a vertical wall due to propagation of bore and surge on dry bed and measured their impact on the wall. Mohapatra et al. (2000) applied Navier Stokes equations to numerically study the impact of bore on vertical and inclined walls. They also obtained the evolution of surge on dry bed. In the present work, the impact of a surge wave due to dam break flow against the wall is modeled with a two-dimensional smoothed particle hydrodynamics (SPH) model. SPH is a mesh-free method that relies on the particle view of the field problem and approximates the continuity and momentum equations on a set of particles. The method solves the strong form of Navier-Stokes equations. The governing equations are solved numerically in the vertical plane. The propagation of the surge wave, its impact and the maximum run-up on the wall located at the boundary are analyzed. Surface profile, velocity field and pressure distributions are simulated. Non-dimensional run-up height obtained from the present numerical model is 0.86 and is in good agreement with the available experimental data of Ramsden (1996) which is in the range of 0.75-0.9. Also, the simulated profile of the surge tip was comparable to the empirical equations refereed in Ramsden (1996). The model is applied to the study the maximum force and the run-up height on inclined walls with different inclinations. The results indicate that the maximum force and the run-up height on the wall increase with the increment of wall inclination. Comparison of numerical results with analytical solutions derived from shallow water equations clearly shows the breakdown of shallow water assumption during the impact. In addition to these results, the numerical simulation yields the complete velocity and pressure ?elds which may be used to design structures located in the path of a dam-break wave. The study shows that the smoothed particle hydrodynamics can effectively simulate fluid flow dynamics. References: Mohapatra, P. K., Bhallamudi, S. M., and Eswaran, V. (2000). 'Numerical simulation of impact of bores against inclined walls.' J. Hydraulic. Engg., ASCE, 126(12), 942-945. Ramsden, J. D. (1996). 'Forces on a vertical wall due to long waves, bores, and dry-bed surges.' J. Waterway, Port, Coastal, and Ocean Engg., ASCE, 122(3), 134-141.

  11. Analysis of ultrasonically rotating droplet using moving particle semi-implicit and distributed point source methods

    NASA Astrophysics Data System (ADS)

    Wada, Yuji; Yuge, Kohei; Tanaka, Hiroki; Nakamura, Kentaro

    2016-07-01

    Numerical analysis of the rotation of an ultrasonically levitated droplet with a free surface boundary is discussed. The ultrasonically levitated droplet is often reported to rotate owing to the surface tangential component of acoustic radiation force. To observe the torque from an acoustic wave and clarify the mechanism underlying the phenomena, it is effective to take advantage of numerical simulation using the distributed point source method (DPSM) and moving particle semi-implicit (MPS) method, both of which do not require a calculation grid or mesh. In this paper, the numerical treatment of the viscoacoustic torque, which emerges from the viscous boundary layer and governs the acoustical droplet rotation, is discussed. The Reynolds stress traction force is calculated from the DPSM result using the idea of effective normal particle velocity through the boundary layer and input to the MPS surface particles. A droplet levitated in an acoustic chamber is simulated using the proposed calculation method. The droplet is vertically supported by a plane standing wave from an ultrasonic driver and subjected to a rotating sound field excited by two acoustic sources on the side wall with different phases. The rotation of the droplet is successfully reproduced numerically and its acceleration is discussed and compared with those in the literature.

  12. Numerical analysis of the formation process of aerosols in the alveoli

    NASA Astrophysics Data System (ADS)

    Haslbeck, Karsten; Seume, Jörg R.

    2008-11-01

    For a successful diagnosis of lung diseases through an analysis of non-volatile molecules in the exhaled breath, an exact understanding of the aerosol formation process is required. This process is modeled using Computational Fluid Dynamics (CFD). The model shows the interaction of the boundary surface between the streamed airway and the local epithelial liquid layer. A 2-D volume mesh of an alveolus is generated by taking into account the connection of the alveoli with the sacculi alveolares (SA). The Volume of Fluid (VOF) Method is used to model the interface between the gas and the liquid film. The non-Newtonian flow is modeled by the implementation of the Ostwald de Waele model. Surface tension is a function of the surfactant concentration. The VOF-Method allows the distribution of the concentration of the epithelial liquid layer at the surface to be traced in a transient manner. The simulations show the rupturing of the liquid film through the drop formation. Aerosol particles are ejected into the SA and do not collide with the walls. The quantity, the geometrical size as well as the velocity distributions of the generated aerosols are determined. The data presented in the paper provide the boundary conditions for future CFD analysis of the aerosol transport through the airways up to exhalation.

  13. Evolution of the mandibular mesh implant.

    PubMed

    Salyer, K E; Johns, D F; Holmes, R E; Layton, J G

    1977-07-01

    Between 1960 and 1972, the Dallas Veterans Administration Hospital Maxillofacial Research Laboratory developed and made over 150 cast-mesh implants. Successive designs were ovoid, circular, and double-lumened in cross section to improve implant strength, surface area for bioattachment, and adjustability. Sleeves, collars, and bows were employed in the assembly of these implants, with an acrylic condylar head attached when indicated. In 1972, our laboratory developed a mandibular mesh tray, cast in one piece on a single sprue, with preservation of the vertically adjustable ramus. Stainless steel replaced Vitallium because of its greater malleability. Essentially, a lost-wax technique is used to cast the mesh tray. The model of a mandibular segment is duplicated as a refractory model. Mesh wax, made in our own custom-made die, is adapted to the refractory model. The unit is then sprued and invested. The wax is fired our of the mold in a gas furnace. Casting is done by the transferral of molten stainless steel from the crucible to the mold by centrifugal force in an electro-induction casting machine. Other mesh implants that have been developed are made from wire mesh, Dacron mesh, cast Ticonium, and hydroformed titanium.

  14. Fabrication and Wettability Study of WO3 Coated Photocatalytic Membrane for Oil-Water Separation: A Comparative Study with ZnO Coated Membrane.

    PubMed

    Gondal, Mohammed A; Sadullah, Muhammad S; Qahtan, Talal F; Dastageer, Mohamed A; Baig, Umair; McKinley, Gareth H

    2017-05-10

    Superhydrophilic and underwater superoleophobic surfaces were fabricated by facile spray coating of nanostructured WO 3 on stainless steel meshes and compared its performance in oil-water separation with ZnO coated meshes. The gravity driven oil-water separation system was designed using these surfaces as the separation media and it was noticed that WO 3 coated stainless steel mesh showed high separation efficiency (99%), with pore size as high as 150 µm, whereas ZnO coated surfaces failed in the process of oil-water separation when the pore exceeded 50 µm size. Since, nanostructured WO 3 is a well known catalyst, the simultaneous photocatalytic degradation of organic pollutants present in the separated water from the oil water separation process were tested using WO 3 coated surfaces under UV radiation and the efficiency of this degradation was found to be quite significant. These results assure that with little improvisation on the oil water separation system, these surfaces can be made multifunctional to work simultaneously for oil-water separation and demineralization of organic pollutants from the separated water. Fabrication of the separating surface, their morphological characteristics, wettability, oil water separation efficiency and photo-catalytic degradation efficiency are enunciated.

  15. Superhydrophobic materials for drug delivery

    NASA Astrophysics Data System (ADS)

    Yohe, Stefan Thomas

    Superhydrophobicity is a property of material surfaces reflecting the ability to maintain air at the solid-liquid interface when in contact with water. These surfaces have characteristically high apparent contact angles, by definition exceeding 150°, as a result of the composite material-air surface formed under an applied water droplet. Superhydrophobic surfaces were first discovered on naturally occurring substrates, and have subsequently been fabricated in the last several decades to harness these favorable surface properties for a number of emerging applications, including their use in biomedical settings. This work describes fabrication and characterization of superhydrophobic 3D materials, as well as their use as drug delivery devices. Superhydrophobic 3D materials are distinct from 2D superhydrophobic surfaces in that air is maintained not just at the surface of the material, but also within the bulk. When the superhydrophobic 3D materials are submerged in water, water infiltrates slowly and continuously as a new water-air-material interface is formed with controlled displacement of air. Electrospinning and electrospraying are used to fabricate superhydrophobic 3D materials utilizing blends of the biocompatible polymers poly(epsilon-caprolactone) and poly(caprolactone-co-glycerol monostearate) (PGC-C18). PGC-C18 is significantly more hydrophobic than PCL (contact angle of 116° versus 83° for flat materials), and further additions of PGC-C18 into electrospun meshes and electrosprayed coatings affords increased stability of the entrapped air layer. For example, PCL meshes alone (500 mum thick) take 10 days to fully wet, and with 10% or 30% PGC-C18 addition wetting rates are dramatically slowed to 60% wetted by 77 days and 4% by 75 days, respectively. Stability of the superhydrophobic materials can be further probed with a variety of physio-chemical techniques, including pressure, surfactant containing solutions, and solvents of varying surface tension. Superhydrophobicity is shown to be enhanced with further increases in PGC-C18 content and surface roughness (a decrease in fiber size). We demonstrate the utility of superhydrophobicity as a method for drug delivery. When the camptothecin derivatives SN-38 and CPT-11 are encapsulated within electrospun meshes, changes in air layer stability (due to changes in PGC-C18 content) dictate the rate of drug release by controlling the rate in which water can permeate into the porous 3D electrospun structure. Drug release can be tuned from 2 weeks to >10 weeks from 300 mum meshes, and meshes effectively kill a variety of cancer cell lines (lung, colon, breast) when utilized in a cytotoxicity assay. After determining that air could be used to control the rate of drug release, superhydrophobic 3D materials are explored for three applications. First, meshes are considered as a potential combination reinforcement-drug delivery device for use in resectable colorectal cancer. Second, removal of the air layer in superhydrophobic meshes is used as a method to trigger drug release. The pressure generated from high-intensity focused ultrasound (0.75-4.25 MPa) can remove the air layer spatially and temporally, allowing drug release to be controlled with application of a sufficient treatment. Third, "connective" electrosprayed coatings are deposited on chemically distinct material surfaces, which are both three-dimensional and mechanically robust. In summary, superhydrophobic 3D materials are fabricated and characterized, and are utilized as drug delivery devices. Controlled air removal from these materials offers an entirely new strategy for drug delivery, and is promising for the applications considered in this work as well as many others.

  16. A simple way to achieve bioinspired hybrid wettability surface with micro/nanopatterns for efficient fog collection.

    PubMed

    Yin, Kai; Du, Haifeng; Dong, Xinran; Wang, Cong; Duan, Ji-An; He, Jun

    2017-10-05

    Fog collection is receiving increasing attention for providing water in semi-arid deserts and inland areas. Inspired by the fog harvesting ability of the hydrophobic-hydrophilic surface of Namib desert beetles, we present a simple, low-cost method to prepare a hybrid superhydrophobic-hydrophilic surface. The surface contains micro/nanopatterns, and is prepared by incorporating femtosecond-laser fabricated polytetrafluoroethylene nanoparticles deposited on superhydrophobic copper mesh with a pristine hydrophilic copper sheet. The as-prepared surface exhibits enhanced fog collection efficiency compared with uniform (super)hydrophobic or (super)hydrophilic surfaces. This enhancement can be tuned by controlling the mesh number, inclination angle, and fabrication structure. Moreover, the surface shows excellent anti-corrosion ability after immersing in 1 M HCl, 1 M NaOH, and 10 wt% NaCl solutions for 2 hours. This work may provide insight into fabricating hybrid superhydrophobic-hydrophilic surfaces for efficient atmospheric water collection.

  17. Methods of Real Time Image Enhancement of Flash LIDAR Data and Navigating a Vehicle Using Flash LIDAR Data

    NASA Technical Reports Server (NTRS)

    Vanek, Michael D. (Inventor)

    2014-01-01

    A method for creating a digital elevation map ("DEM") from frames of flash LIDAR data includes generating a first distance R(sub i) from a first detector i to a first point on a surface S(sub i). After defining a map with a mesh THETA having cells k, a first array S(k), a second array M(k), and a third array D(k) are initialized. The first array corresponds to the surface, the second array corresponds to the elevation map, and the third array D(k) receives an output for the DEM. The surface is projected onto the mesh THETA, so that a second distance R(sub k) from a second point on the mesh THETA to the detector can be found. From this, a height may be calculated, which permits the generation of a digital elevation map. Also, using sequential frames of flash LIDAR data, vehicle control is possible using an offset between successive frames.

  18. Method for Enhancing a Three Dimensional Image from a Plurality of Frames of Flash LIDAR Data

    NASA Technical Reports Server (NTRS)

    Bulyshev, Alexander (Inventor); Vanek, Michael D. (Inventor); Amzajerdian, Farzin (Inventor)

    2013-01-01

    A method for enhancing a three dimensional image from frames of flash LIDAR data includes generating a first distance R(sub i) from a first detector i to a first point on a surface S(sub i). After defining a map with a mesh theta having cells k, a first array S(k), a second array M(k), and a third array D(k) are initialized. The first array corresponds to the surface, the second array corresponds to the elevation map, and the third array D(k) receives an output for the DEM. The surface is projected onto the mesh theta, so that a second distance R(sub k) from a second point on the mesh theta to the detector can be found. From this, a height may be calculated, which permits the generation of a digital elevation map. Also, using sequential frames of flash LIDAR data, vehicle control is possible using an offset between successive frames.

  19. Using an Adjoint Approach to Eliminate Mesh Sensitivities in Computational Design

    NASA Technical Reports Server (NTRS)

    Nielsen, Eric J.; Park, Michael A.

    2006-01-01

    An algorithm for efficiently incorporating the effects of mesh sensitivities in a computational design framework is introduced. The method is based on an adjoint approach and eliminates the need for explicit linearizations of the mesh movement scheme with respect to the geometric parameterization variables, an expense that has hindered practical large-scale design optimization using discrete adjoint methods. The effects of the mesh sensitivities can be accounted for through the solution of an adjoint problem equivalent in cost to a single mesh movement computation, followed by an explicit matrix-vector product scaling with the number of design variables and the resolution of the parameterized surface grid. The accuracy of the implementation is established and dramatic computational savings obtained using the new approach are demonstrated using several test cases. Sample design optimizations are also shown.

  20. Using an Adjoint Approach to Eliminate Mesh Sensitivities in Computational Design

    NASA Technical Reports Server (NTRS)

    Nielsen, Eric J.; Park, Michael A.

    2005-01-01

    An algorithm for efficiently incorporating the effects of mesh sensitivities in a computational design framework is introduced. The method is based on an adjoint approach and eliminates the need for explicit linearizations of the mesh movement scheme with respect to the geometric parameterization variables, an expense that has hindered practical large-scale design optimization using discrete adjoint methods. The effects of the mesh sensitivities can be accounted for through the solution of an adjoint problem equivalent in cost to a single mesh movement computation, followed by an explicit matrix-vector product scaling with the number of design variables and the resolution of the parameterized surface grid. The accuracy of the implementation is established and dramatic computational savings obtained using the new approach are demonstrated using several test cases. Sample design optimizations are also shown.

  1. Development of a Flexible Framework of Common Hypersonic Navier-Strokes Meshes for the Space Shuttle Orbiter

    NASA Technical Reports Server (NTRS)

    Alter, Stephen J.; Reuthler, James J.; McDaniel, Ryan D.

    2003-01-01

    A flexible framework for the development of block structured volume grids for hypersonic Navier-Stokes flow simulations was developed for analysis of the Shuttle Orbiter Columbia. The development of the flexible framework, resulted in an ability to quickly generate meshes to directly correlate solutions contributed by participating groups on a common surface mesh, providing confidence for the extension of the envelope of solutions and damage scenarios. The framework draws on the experience of NASA Langely and NASA Ames Research Centers in structured grid generation, and consists of a grid generation process that is implemented through a division of responsibilities. The nominal division of labor consisted of NASA Johnson Space Center coordinating the damage scenarios to be analyzed by the Aerothermodynamics Columbia Accident Investigation (CAI) team, Ames developing the surface grids that described the computational volume about the orbiter, and Langely improving grid quality of Ames generated data and constructing the final volume grids. Distributing the work among the participants in the Aerothermodynamic CIA team resulted in significantly less time required to construct complete meshes than possible by any individual participant. The approach demonstrated that the One-NASA grid generation team could sustain the demand for new meshes to explore new damage scenarios within a aggressive timeline.

  2. Fluid Structure Interaction Techniques For Extrusion And Mixing Processes

    NASA Astrophysics Data System (ADS)

    Valette, Rudy; Vergnes, Bruno; Coupez, Thierry

    2007-05-01

    This work focuses on the development of numerical techniques devoted to the simulation of mixing processes of complex fluids such as twin-screw extrusion or batch mixing. In mixing process simulation, the absence of symmetry of the moving boundaries (the screws or the rotors) implies that their rigid body motion has to be taken into account by using a special treatment We therefore use a mesh immersion technique (MIT), which consists in using a P1+/P1-based (MINI-element) mixed finite element method for solving the velocity-pressure problem and then solving the problem in the whole barrel cavity by imposing a rigid motion (rotation) to nodes found located inside the so called immersed domain, each sub-domain (screw, rotor) being represented by a surface CAD mesh (or its mathematical equation in simple cases). The independent meshes are immersed into a unique background computational mesh by computing the distance function to their boundaries. Intersections of meshes are accounted for, allowing to compute a fill factor usable as for the VOF methodology. This technique, combined with the use of parallel computing, allows to compute the time-dependent flow of generalized Newtonian fluids including yield stress fluids in a complex system such as a twin screw extruder, including moving free surfaces, which are treated by a "level set" and Hamilton-Jacobi method.

  3. Fatigue crack growth behaviour of semi-elliptical surface cracks for an API 5L X65 gas pipeline under tension

    NASA Astrophysics Data System (ADS)

    Shaari, M. S.; Akramin, M. R. M.; Ariffin, A. K.; Abdullah, S.; Kikuchi, M.

    2018-02-01

    The paper is presenting the fatigue crack growth (FCG) behavior of semi-elliptical surface cracks for API X65 gas pipeline using S-version FEM. A method known as global-local overlay technique was used in this study to predict the fatigue behavior that involve of two separate meshes each specifically for global (geometry) and local (crack). The pre-post program was used to model the global geometry (coarser mesh) known as FAST including the material and boundary conditions. Hence, the local crack (finer mesh) will be defined the exact location and the mesh control accordingly. The local mesh was overlaid along with the global before the numerical computation taken place to solve the engineering problem. The stress intensity factors were computed using the virtual crack closure-integral method (VCCM). The most important results is the behavior of the fatigue crack growth, which contains the crack depth (a), crack length (c) and stress intensity factors (SIF). The correlation between the fatigue crack growth and the SIF shows a good growth for the crack depth (a) and dissimilar for the crack length (c) where stunned behavior was resulted. The S-version FEM will benefiting the user due to the overlay technique where it will shorten the computation process.

  4. Lessons and challenges during a 5-year follow-up of 21 Composix Kugel implantations.

    PubMed

    Wiegering, A; Schlegel, N; Isbert, C; Jurowich, C; Doht, S; Germer, C T; Dietz, U A

    2013-08-01

    From its introduction in 2000 until its US recall in December 2005, the Composix Kugel mesh was implanted in an estimated 350,000 patients worldwide. In our patients, minor postoperative complications were followed after a few years by more serious problems (persistent abdominal pain, infections, intestinal perforations). In this study, we take stock after a 5-year follow-up and issue a plea for improved product development strategies and the creation of hernia registries. Between 2003 and 2006, we implanted the Bard(®) Composix(®) Kugel(®) mesh in 21 patients (11 men, 10 women, mean age 63.2 ± 13.7 years) with incisional hernias using the open intraperitoneal onlay mesh technique. The mesh is made on one side of ePTFE and on the other of polypropylene and is expanded by a polyethylene (PET) memory recoil ring. The average follow-up was 45.5 months. All patients had at least one risk factor for hernia recurrence. Explanted prostheses were analyzed by scanning electron microscopy (SEM) and subjected to mechanical strength tests. During the postoperative course, six patients suffered a wound healing disorder. Ten patients complained of persistent abdominal wall pain and four experienced recurrence of the hernia. In one patient, the mesh had to be explanted due to chronic infection. In one patient, the PET memory recoil ring broke after 5 years of follow-up with consequent small bowel perforation. The PET memory recoil ring exhibited clear signs of degradation on SEM and unmistakable signs of material fatigue in a materials testing machine. Patients with recalled Composix Kugel meshes face a singular risk for complications that may occur even many years after implantation. The most serious complication is the breakage of its PET memory recoil ring. Since the recall of the Composix Kugel Mesh, we have discontinued its use. It is necessary that future complications are documented in a common post-market surveillance registry. Algorithms need to be developed and promoted to support affected patients and surgeons.

  5. Minimal Invasive Linea Alba Reconstruction for the Treatment of Umbilical and Epigastric Hernias with Coexisting Rectus Abdominis Diastasis.

    PubMed

    Köhler, Gernot; Fischer, Ines; Kaltenböck, Richard; Schrittwieser, Rudolf

    2018-04-05

    Patients with umbilical or epigastric hernias benefit from mesh- based repairs, and even more so if a concomitant rectus diastasis (RD) is present. The ideal technique is, however, still under debate. In this study we introduce the minimal invasive linea alba reconstruction (MILAR) with the supraaponeurotic placement of a fully absorbable synthetic mesh. Midline reconstruction with anterior rectus sheath repair and mesh augmentation by an open approach is a well-known surgical technique for ventral hernia repair. Between December 1, 2016, and November 30, 2017, 20 patients with symptomatic umbilical and/or epigastric hernias, and coexisting RD underwent a minimally invasive complete reconstruction of the midline through a small access route. The inner part of both incised and medialized anterior rectus sheaths was replaced by a fully absorbable synthetic mesh placed in a supraaponeurotic position. Patients were hospitalized for an average of 4 days and the mean operating time was 79 minutes. The mean hernia defect size was 1.5 cm in diameter and the mean mesh size was recorded as 15.8 cm in length and 5.2 cm in width. Two patients sustained surgical postoperative complications in terms of symptomatic seroma occurrences with successful interventional treatment.The early results (mean follow-up period of 5 months) showed no recurrences and only 1 patient reported occasional pain following exertion without rest. MILAR is a modification of the recently published endoscopic linea alba reconstruction restoring the normal anatomy of the abdominal wall. A new linea alba is formed with augmentation of autologous tissue consisting of the plicated anterior rectus sheaths. Supraaponeurotic placement of a fully absorbable synthetic mesh eliminates potential long-term mesh-associated complications. Regarding MILAR, there is no need for endoscopic equipment due to the uniquely designed flexible lighted retractors, meaning one assistant less is required.

  6. Development of a Dynamically Configurable, Object-Oriented Framework for Distributed, Multi-modal Computational Aerospace Systems Simulation: Second Year Progress Report

    NASA Technical Reports Server (NTRS)

    Afjeh, Abdollah A.; Reed, John A.

    2003-01-01

    Mesh generation has long been recognized as a bottleneck in the CFD process. While much research on automating the volume mesh generation process have been relatively successful,these methods rely on appropriate initial surface triangulation to work properly. Surface discretization has been one of the least automated steps in computational simulation due to its dependence on implicitly defined CAD surfaces and curves. Differences in CAD peometry engines manifest themselves in discrepancies in their interpretation of the same entities. This lack of "good" geometry causes significant problems for mesh generators, requiring users to "repair" the CAD geometry before mesh generation. The problem is exacerbated when CAD geometry is translated to other forms (e.g., IGES )which do not include important topological and construction information in addition to entity geometry. One technique to avoid these problems is to access the CAD geometry directly from the mesh generating software, rather than through files. By accessing the geometry model (not a discretized version) in its native environment, t h s a proach avoids translation to a format which can deplete the model of topological information. Our approach to enable models developed in the Denali software environment to directly access CAD geometry and functions is through an Application Programming Interface (API) known as CAPRI. CAPRI provides a layer of indirection through which CAD-specific data may be accessed by an application program using CAD-system neutral C and FORTRAN language function calls. CAPRI supports a general set of CAD operations such as truth testing, geometry construction and entity queries.

  7. 3D Tensorial Elastodynamics for Isotropic Media on Vertically Deformed Meshes

    NASA Astrophysics Data System (ADS)

    Shragge, J. C.

    2017-12-01

    Solutions of the 3D elastodynamic wave equation are sometimes required in industrial and academic applications of elastic reverse-time migration (E-RTM) and full waveform inversion (E-FWI) that involve vertically deformed meshes. Examples include incorporating irregular free-surface topography and handling internal boundaries (e.g., water bottom) directly into the computational meshes. In 3D E-RTM and E-FWI applications, the number of forward modeling simulations can number in the tens of thousands (per iteration), which necessitates the development of stable, accurate and efficient 3D elastodynamics solvers. For topographic scenarios, most finite-difference solution approaches use a change-of-variable strategy that has a number of associated computational challenges, including difficulties in handling of the free-surface boundary condition. In this study, I follow a tensorial approach and use a generalized family of analytic transforms to develop a set of analytic equations for 3D elastodynamics that directly incorporates vertical grid deformations. Importantly, this analytic approach allows for the specification of an analytic free-surface boundary condition appropriate for vertically deformed meshes. These equations are both straightforward and efficient to solve using a velocity-stress formulation with finite-difference (MFD) operators implemented on a fully staggered grid. Moreover, I demonstrate that the use of mimetic finite difference (MFD) methods allows stable, accurate, and efficient numerical solutions to be simulated for typical topographic scenarios. Examples demonstrate that high-quality elastic wavefields can be generated for topographic surfaces exhibiting significant topographic relief.

  8. Efficiently computing exact geodesic loops within finite steps.

    PubMed

    Xin, Shi-Qing; He, Ying; Fu, Chi-Wing

    2012-06-01

    Closed geodesics, or geodesic loops, are crucial to the study of differential topology and differential geometry. Although the existence and properties of closed geodesics on smooth surfaces have been widely studied in mathematics community, relatively little progress has been made on how to compute them on polygonal surfaces. Most existing algorithms simply consider the mesh as a graph and so the resultant loops are restricted only on mesh edges, which are far from the actual geodesics. This paper is the first to prove the existence and uniqueness of geodesic loop restricted on a closed face sequence; it contributes also with an efficient algorithm to iteratively evolve an initial closed path on a given mesh into an exact geodesic loop within finite steps. Our proposed algorithm takes only an O(k) space complexity and an O(mk) time complexity (experimentally), where m is the number of vertices in the region bounded by the initial loop and the resultant geodesic loop, and k is the average number of edges in the edge sequences that the evolving loop passes through. In contrast to the existing geodesic curvature flow methods which compute an approximate geodesic loop within a predefined threshold, our method is exact and can apply directly to triangular meshes without needing to solve any differential equation with a numerical solver; it can run at interactive speed, e.g., in the order of milliseconds, for a mesh with around 50K vertices, and hence, significantly outperforms existing algorithms. Actually, our algorithm could run at interactive speed even for larger meshes. Besides the complexity of the input mesh, the geometric shape could also affect the number of evolving steps, i.e., the performance. We motivate our algorithm with an interactive shape segmentation example shown later in the paper.

  9. Procedure for Tooth Contact Analysis of a Face Gear Meshing With a Spur Gear Using Finite Element Analysis

    NASA Technical Reports Server (NTRS)

    Bibel, George; Lewicki, David G. (Technical Monitor)

    2002-01-01

    A procedure was developed to perform tooth contact analysis between a face gear meshing with a spur pinion using finite element analysis. The face gear surface points from a previous analysis were used to create a connected tooth solid model without gaps or overlaps. The face gear surface points were used to create a five tooth face gear Patran model (with rim) using Patran PCL commands. These commands were saved in a series of session files suitable for Patran input. A four tooth spur gear that meshes with the face gear was designed and constructed with Patran PCL commands. These commands were also saved in a session files suitable for Patran input. The orientation of the spur gear required for meshing with the face gear was determined. The required rotations and translations are described and built into the session file for the spur gear. The Abaqus commands for three-dimensional meshing were determined and verified for a simplified model containing one spur tooth and one face gear tooth. The boundary conditions, loads, and weak spring constraints were determined to make the simplified model work. The load steps and load increments to establish contact and obtain a realistic load was determined for the simplified two tooth model. Contact patterns give some insight into required mesh density. Building the two gears in two different local coordinate systems and rotating the local coordinate systems was verified as an easy way to roll the gearset through mesh. Due to limitation of swap space, disk space and time constraints of the summer period, the larger model was not completed.

  10. Adjoint Sensitivity Computations for an Embedded-Boundary Cartesian Mesh Method and CAD Geometry

    NASA Technical Reports Server (NTRS)

    Nemec, Marian; Aftosmis,Michael J.

    2006-01-01

    Cartesian-mesh methods are perhaps the most promising approach for addressing the issues of flow solution automation for aerodynamic design problems. In these methods, the discretization of the wetted surface is decoupled from that of the volume mesh. This not only enables fast and robust mesh generation for geometry of arbitrary complexity, but also facilitates access to geometry modeling and manipulation using parametric Computer-Aided Design (CAD) tools. Our goal is to combine the automation capabilities of Cartesian methods with an eficient computation of design sensitivities. We address this issue using the adjoint method, where the computational cost of the design sensitivities, or objective function gradients, is esseutially indepeudent of the number of design variables. In previous work, we presented an accurate and efficient algorithm for the solution of the adjoint Euler equations discretized on Cartesian meshes with embedded, cut-cell boundaries. Novel aspects of the algorithm included the computation of surface shape sensitivities for triangulations based on parametric-CAD models and the linearization of the coupling between the surface triangulation and the cut-cells. The objective of the present work is to extend our adjoint formulation to problems involving general shape changes. Central to this development is the computation of volume-mesh sensitivities to obtain a reliable approximation of the objective finction gradient. Motivated by the success of mesh-perturbation schemes commonly used in body-fitted unstructured formulations, we propose an approach based on a local linearization of a mesh-perturbation scheme similar to the spring analogy. This approach circumvents most of the difficulties that arise due to non-smooth changes in the cut-cell layer as the boundary shape evolves and provides a consistent approximation tot he exact gradient of the discretized abjective function. A detailed gradient accurace study is presented to verify our approach. Thereafter, we focus on a shape optimization problem for an Apollo-like reentry capsule. The optimization seeks to enhance the lift-to-drag ratio of the capsule by modifyjing the shape of its heat-shield in conjunction with a center-of-gravity (c.g.) offset. This multipoint and multi-objective optimization problem is used to demonstrate the overall effectiveness of the Cartesian adjoint method for addressing the issues of complex aerodynamic design. This abstract presents only a brief outline of the numerical method and results; full details will be given in the final paper.

  11. Tangle-Free Finite Element Mesh Motion for Ablation Problems

    NASA Technical Reports Server (NTRS)

    Droba, Justin

    2016-01-01

    Mesh motion is the process by which a computational domain is updated in time to reflect physical changes in the material the domain represents. Such a technique is needed in the study of the thermal response of ablative materials, which erode when strong heating is applied to the boundary. Traditionally, the thermal solver is coupled with a linear elastic or biharmonic system whose sole purpose is to update mesh node locations in response to altering boundary heating. Simple mesh motion algorithms rely on boundary surface normals. In such schemes, evolution in time will eventually cause the mesh to intersect and "tangle" with itself, causing failure. Furthermore, such schemes are greatly limited in the problems geometries on which they will be successful. This paper presents a comprehensive and sophisticated scheme that tailors the directions of motion based on context. By choosing directions for each node smartly, the inevitable tangle can be completely avoided and mesh motion on complex geometries can be modeled accurately.

  12. Semi-regular remeshing based trust region spherical geometry image for 3D deformed mesh used MLWNN

    NASA Astrophysics Data System (ADS)

    Dhibi, Naziha; Elkefi, Akram; Bellil, Wajdi; Ben Amar, Chokri

    2017-03-01

    Triangular surface are now widely used for modeling three-dimensional object, since these models are very high resolution and the geometry of the mesh is often very dense, it is then necessary to remesh this object to reduce their complexity, the mesh quality (connectivity regularity) must be ameliorated. In this paper, we review the main methods of semi-regular remeshing of the state of the art, given the semi-regular remeshing is mainly relevant for wavelet-based compression, then we present our method for re-meshing based trust region spherical geometry image to have good scheme of 3d mesh compression used to deform 3D meh based on Multi library Wavelet Neural Network structure (MLWNN). Experimental results show that the progressive re-meshing algorithm capable of obtaining more compact representations and semi-regular objects and yield an efficient compression capabilities with minimal set of features used to have good 3D deformation scheme.

  13. Effects of Mesh Irregularities on Accuracy of Finite-Volume Discretization Schemes

    NASA Technical Reports Server (NTRS)

    Diskin, Boris; Thomas, James L.

    2012-01-01

    The effects of mesh irregularities on accuracy of unstructured node-centered finite-volume discretizations are considered. The focus is on an edge-based approach that uses unweighted least-squares gradient reconstruction with a quadratic fit. For inviscid fluxes, the discretization is nominally third order accurate on general triangular meshes. For viscous fluxes, the scheme is an average-least-squares formulation that is nominally second order accurate and contrasted with a common Green-Gauss discretization scheme. Gradient errors, truncation errors, and discretization errors are separately studied according to a previously introduced comprehensive methodology. The methodology considers three classes of grids: isotropic grids in a rectangular geometry, anisotropic grids typical of adapted grids, and anisotropic grids over a curved surface typical of advancing layer grids. The meshes within the classes range from regular to extremely irregular including meshes with random perturbation of nodes. Recommendations are made concerning the discretization schemes that are expected to be least sensitive to mesh irregularities in applications to turbulent flows in complex geometries.

  14. Experimental and numerical analysis of pre-compressed masonry walls in two-way-bending with second order effects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Milani, Gabriele, E-mail: milani@stru.polimi.it; Olivito, Renato S.; Tralli, Antonio

    2014-10-06

    The buckling behavior of slender unreinforced masonry (URM) walls subjected to axial compression and out-of-plane lateral loads is investigated through a combined experimental and numerical homogenizedapproach. After a preliminary analysis performed on a unit cell meshed by means of elastic FEs and non-linear interfaces, macroscopic moment-curvature diagrams so obtained are implemented at a structural level, discretizing masonry by means of rigid triangular elements and non-linear interfaces. The non-linear incremental response of the structure is accounted for a specific quadratic programming routine. In parallel, a wide experimental campaign is conducted on walls in two way bending, with the double aim ofmore » both validating the numerical model and investigating the behavior of walls that may not be reduced to simple cantilevers or simply supported beams. Panels investigated are dry-joint in scale square walls simply supported at the base and on a vertical edge, exhibiting the classical Rondelet’s mechanism. The results obtained are compared with those provided by the numerical model.« less

  15. Accuracy Assessment of a Canal-Tunnel 3d Model by Comparing Photogrammetry and Laserscanning Recording Techniques

    NASA Astrophysics Data System (ADS)

    Charbonnier, P.; Chavant, P.; Foucher, P.; Muzet, V.; Prybyla, D.; Perrin, T.; Grussenmeyer, P.; Guillemin, S.

    2013-07-01

    With recent developments in the field of technology and computer science, conventional methods are being supplanted by laser scanning and digital photogrammetry. These two different surveying techniques generate 3-D models of real world objects or structures. In this paper, we consider the application of terrestrial Laser scanning (TLS) and photogrammetry to the surveying of canal tunnels. The inspection of such structures requires time, safe access, specific processing and professional operators. Therefore, a French partnership proposes to develop a dedicated equipment based on image processing for visual inspection of canal tunnels. A 3D model of the vault and side walls of the tunnel is constructed from images recorded onboard a boat moving inside the tunnel. To assess the accuracy of this photogrammetric model (PM), a reference model is build using static TLS. We here address the problem comparing the resulting point clouds. Difficulties arise because of the highly differentiated acquisition processes, which result in very different point densities. We propose a new tool, designed to compare differences between pairs of point cloud or surfaces (triangulated meshes). Moreover, dealing with huge datasets requires the implementation of appropriate structures and algorithms. Several techniques are presented : point-to-point, cloud-to-cloud and cloud-to-mesh. In addition farthest point resampling, octree structure and Hausdorff distance are adopted and described. Experimental results are shown for a 475 m long canal tunnel located in France.

  16. Computer Simulations of Coronary Blood Flow Through a Constriction

    DTIC Science & Technology

    2014-03-01

    interventional procedures (e.g., stent deployment). Building off previous models that have been partially validated with experimental data, this thesis... stent deployment). Building off previous models that have been partially validated with experimental data, this thesis continues to develop the...the artery and increase blood flow. Generally a stent , or a mesh wire tube, is permanently inserted in order to scaffold open the artery wall

  17. Through-the-Wall Small Weapon Detection Based on Polarimetric Radar Techniques

    DTIC Science & Technology

    2009-12-01

    waves can penetrate through clothing (textile materials ), they have very poor penetration properties through many common construction materials (such...including the continuous metallic barrel ). Unless specified otherwise, the mesh has a resolution (cell size) of 2 mm. The wood dielectric constant...almost perpendicularly to the barrel ). Figure 2. Estimating the tilt angle of a cylindrical metallic rod of 1 m length

  18. Application of the method of lines for solutions of the Navier-Stokes equations using a nonuniform grid distribution

    NASA Technical Reports Server (NTRS)

    Abolhassani, J. S.; Tiwari, S. N.

    1983-01-01

    The feasibility of the method of lines for solutions of physical problems requiring nonuniform grid distributions is investigated. To attain this, it is also necessary to investigate the stiffness characteristics of the pertinent equations. For specific applications, the governing equations considered are those for viscous, incompressible, two dimensional and axisymmetric flows. These equations are transformed from the physical domain having a variable mesh to a computational domain with a uniform mesh. The two governing partial differential equations are the vorticity and stream function equations. The method of lines is used to solve the vorticity equation and the successive over relaxation technique is used to solve the stream function equation. The method is applied to three laminar flow problems: the flow in ducts, curved-wall diffusers, and a driven cavity. Results obtained for different flow conditions are in good agreement with available analytical and numerical solutions. The viability and validity of the method of lines are demonstrated by its application to Navier-Stokes equations in the physical domain having a variable mesh.

  19. Colonic obstruction secondary to incarcerated Spigelian hernia in a severely obese patient.

    PubMed

    Salemis, Nikolaos S; Kontoravdis, Nikolaos; Gourgiotis, Stavros; Panagiotopoulos, Nikolaos; Gakis, Christos; Dimitrakopoulos, Georgios

    2010-01-01

    Spigelian hernia is a rare hernia of the ventral abdominal wall accounting for 1-2% of all hernias. Incarceration of a Spigelian hernia has been reported in 17-24% of the cases. We herein describe an extremely rare case of a colonic obstruction secondary to an incarcerated Spigelian hernia in a severely obese patient. Physical examination was inconclusive and diagnosis was established by computed tomography scans. The patient underwent an open intraperitoneal mesh repair. A high level of suspicion and awareness is required as clinical findings of a Spigelian hernia are often nonspecific especially in obese patients. Computed tomography scan provides detailed information for the surgical planning. Open mesh repair is safe in the emergent surgical intervention of a complicated Spigelian hernia in severely obese patients.

  20. Colonic obstruction secondary to incarcerated Spigelian hernia in a severely obese patient

    PubMed Central

    Salemis, Nikolaos S.; Kontoravdis, Nikolaos; Gourgiotis, Stavros; Panagiotopoulos, Nikolaos; Gakis, Christos; Dimitrakopoulos, Georgios

    2010-01-01

    Spigelian hernia is a rare hernia of the ventral abdominal wall accounting for 1–2% of all hernias. Incarceration of a Spigelian hernia has been reported in 17–24% of the cases. We herein describe an extremely rare case of a colonic obstruction secondary to an incarcerated Spigelian hernia in a severely obese patient. Physical examination was inconclusive and diagnosis was established by computed tomography scans. The patient underwent an open intraperitoneal mesh repair. A high level of suspicion and awareness is required as clinical findings of a Spigelian hernia are often nonspecific especially in obese patients. Computed tomography scan provides detailed information for the surgical planning. Open mesh repair is safe in the emergent surgical intervention of a complicated Spigelian hernia in severely obese patients. PMID:22096670

  1. A very simple technique to repair Grynfeltt-Lesshaft hernia.

    PubMed

    Solaini, Leonardo; di Francesco, F; Gourgiotis, S; Solaini, Luciano

    2010-08-01

    A very simple technique to repair a superior lumbar hernia is described. The location of this type of hernia, also known as the Grynfeltt-Lesshaft hernia, is defined by a triangle placed in the lumbar region. An unusual case of a 67-year-old woman with a superior lumbar hernia is reported. The diagnosis was made by physical examination. The defect of the posterior abdominal wall was repaired with a polypropylene dart mesh. The patient had no evidence of recurrence at 11 months follow up. The surgical approach described in this paper is simple and easy to perform, and its result is comparable with other techniques that are much more sophisticated. No cases on the use of dart mesh to repair Grynfeltt-Lesshaft hernia have been reported by surgical journals indexed in PubMed.

  2. International consensus conference on open abdomen in trauma.

    PubMed

    Chiara, Osvaldo; Cimbanassi, Stefania; Biffl, Walter; Leppaniemi, Ari; Henry, Sharon; Scalea, Thomas M; Catena, Fausto; Ansaloni, Luca; Chieregato, Arturo; de Blasio, Elvio; Gambale, Giorgio; Gordini, Giovanni; Nardi, Guiseppe; Paldalino, Pietro; Gossetti, Francesco; Dionigi, Paolo; Noschese, Giuseppe; Tugnoli, Gregorio; Ribaldi, Sergio; Sgardello, Sebastian; Magnone, Stefano; Rausei, Stefano; Mariani, Anna; Mengoli, Francesca; di Saverio, Salomone; Castriconi, Maurizio; Coccolini, Federico; Negreanu, Joseph; Razzi, Salvatore; Coniglio, Carlo; Morelli, Francesco; Buonanno, Maurizio; Lippi, Monica; Trotta, Liliana; Volpi, Annalisa; Fattori, Luca; Zago, Mauro; de Rai, Paolo; Sammartano, Fabrizio; Manfredi, Roberto; Cingolani, Emiliano

    2016-01-01

    A part of damage-control laparotomy is to leave the fascial edges and the skin open to avoid abdominal compartment syndrome and allow further explorations. This condition, known as open abdomen (OA), although effective, is associated with severe complications. Our aim was to develop evidence-based recommendations to define indications for OA, techniques for temporary abdominal closure, management of enteric fistulas, and methods of definitive wall closure. The literature from 1990 to 2014 was systematically screened according to PRISMA [Preferred Reporting Items for Systematic Reviews and Meta-analyses] protocol. Seventy-six articles were reviewed by a panel of experts to assign grade of recommendations (GoR) and level of evidence (LoE) using the GRADE [Grading of Recommendations Assessment, Development, and Evaluation] system, and an international consensus conference was held. OA in trauma is indicated at the end of damage-control laparotomy, in the presence of visceral swelling, for a second look in vascular injuries or gross contamination, in the case of abdominal wall loss, and if medical treatment of abdominal compartment syndrome has failed (GoR B, LoE II). Negative-pressure wound therapy is the recommended temporary abdominal closure technique to drain peritoneal fluid, improve nursing, and prevent fascial retraction (GoR B, LoE I). Lack of OA closure within 8 days (GoR C, LoE II), bowel injuries, high-volume replacement, and use of polypropylene mesh over the bowel (GoR C, LoE I) are risk factors for frozen abdomen and fistula formation. Negative-pressure wound therapy allows to isolate the fistula and protect the surrounding tissues from spillage until granulation (GoR C, LoE II). Correction of fistula is performed after 6 months to 12 months. Definitive closure of OA has to be obtained early (GoR C, LoE I) with direct suture, traction devices, component separation with or without mesh. Biologic meshes are an option for wall reinforcement if bacterial contamination is present (GoR C, LoE II). OA and negative-pressure techniques improve the care of trauma patients, but closure must be achieved early to avoid complications.

  3. Repair of a Giant Omphalocele in an Infant With a Pericardial Implant Crosslinked With Oligourethane.

    PubMed

    Vargas-Mancilla, Juan; Torrero-Serrato, María A; Palacios-Rodríguez, Aarón J; Rodríguez-de León, Gloria B; Montes-Rodríguez, Metzeri I; Mendoza-Novelo, Birzabith

    2018-04-16

    The giant omphalocele (GO) represents a challenge for the pediatric surgeon in its management and wall abdominoplasty. Here, we report the outcome of a case in which a GO in a newborn patient was repaired with an implant derived from decellularized bovine pericardium crosslinked with oligourethane. The implantation time was extended for 6 months. This was then followed up by the retrieval of the implant and the subsequent reconstruction in a second surgical time by the closure of the abdominal wall fascia. A short hospital stay, early integration into the patient's family environment, as well as early onset of the oral route without special care of the implant or reconstructed wall nor food restrictions were observed. The reduced presence of the complications described in the literature after application of surgical meshes suggests that this implant can be an effective and safe alternative method in the treatment of abdominal wall defects such as GO. © 2018 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  4. Patterns of muscular strain in the embryonic heart wall.

    PubMed

    Damon, Brooke J; Rémond, Mathieu C; Bigelow, Michael R; Trusk, Thomas C; Xie, Wenjie; Perucchio, Renato; Sedmera, David; Denslow, Stewart; Thompson, Robert P

    2009-06-01

    The hypothesis that inner layers of contracting muscular tubes undergo greater strain than concentric outer layers was tested by numerical modeling and by confocal microscopy of strain within the wall of the early chick heart. We modeled the looped heart as a thin muscular shell surrounding an inner layer of sponge-like trabeculae by two methods: calculation within a two-dimensional three-variable lumped model and simulated expansion of a three-dimensional, four-layer mesh of finite elements. Analysis of both models, and correlative microscopy of chamber dimensions, sarcomere spacing, and membrane leaks, indicate a gradient of strain decreasing across the wall from highest strain along inner layers. Prediction of wall thickening during expansion was confirmed by ultrasonography of beating hearts. Degree of stretch determined by radial position may thus contribute to observed patterns of regional myocardial conditioning and slowed proliferation, as well as to the morphogenesis of ventricular trabeculae and conduction fascicles. Developmental Dynamics 238:1535-1546, 2009. (c) 2009 Wiley-Liss, Inc.

  5. Laparoscopic Sacral Colpopexy: The "6-Points" Technique.

    PubMed

    Schaub, Marie; Lecointre, Lise; Faller, Emilie; Boisramé, Thomas; Baldauf, Jean-Jacques; Wattiez, Arnaud; Akladios, Cherif Youssef

    To illustrate laparoscopic sacral colpopexy for pelvic organ prolapse, a new method using a simplified mesh fixation technique, with only 6 fixing points. Step-by-step explanation of the surgery using video (educative video). The video was approved by the local institutional review board. University Hospital of Strasbourg, France (Canadian Task Force Classification III). Women with multicompartment prolapse. We first dissected the promontorium and vertically incise the posterior parietal peritoneum on the right pelvic sidewall up the pouch of Douglas. We then dissect the rectovaginal septum up to the anal cap, laterally exposing the puborectalis muscle on each side. Middle rectal vessels can be coagulated and cut without increasing the risk of digestive disorders (especially constipation), but it is preferable to conserve them if the space is sufficient for suture. Then, we dissect the vesicovaginal space and realized the subtotal hysterectomy. Finally, we realized the fastening of the anterior and posterior meshes. The particularity is that we performed only 6 points for fixing the meshes: 1 on the puborectalis muscle on each side without tension (to reduce the risk of mesh contracture, dyspareunia, and chronic pelvic pain), 1 for the fixing of the anterior mesh on the anterior vaginal wall at the level of the bladder neck, and 1 on each side of the cervix for the reconstitution of the pericervical ring gathering together the anterior mesh, the pubocervical fascia, and the insertion of the uterosacral ligament at the level of the cervix and the posterior mesh. The sixth stitch fastened 1 of 2 meshes to the anterior paravertebral ligament at the level of the sacral promontory. We finished with the peritonization. The duration of surgery lasts approximately 120 minutes in well-experienced hands. Based on our experience the 6-point technique was relatively simple (few laparoscopic stiches) with few operative difficulties and was also associated with a low rate of reintervention. Surgical management of middle compartment prolapse could be performed quickly and efficiently under laparoscopy with the "6-points" technique. Copyright © 2017 AAGL. Published by Elsevier Inc. All rights reserved.

  6. Self-locking telescoping manipulator arm

    NASA Technical Reports Server (NTRS)

    Nesmith, M. F. (Inventor)

    1985-01-01

    A telescoping manipulator arm and pivotable finger assembly are disclosed. The telescoping arm assembly includes a generally T-shaped arm having three outwardly extending fingers guided on grooved roller guides to compensate for environmental variations. The pivotable finger assembly includes four pivoting fingers. Arcuate teeth are formed on the ends of the fingers. A rack having teeth on four sides meshes with each one of the fingers. One surface of the rack includes teeth along its entire surface which mesh with teeth of one of the fingers. The teeth at the remote end of the rack engage teeth of a gear wheel. The wheel includes a worm which meshes with a worn drive shaft of the drive motor providing a ninety degree self-locking drive for locking the fingers in a desired position. A similar drive provides a self-locking drive for positioning the telescoping arm.

  7. Automated 3D closed surface segmentation: application to vertebral body segmentation in CT images.

    PubMed

    Liu, Shuang; Xie, Yiting; Reeves, Anthony P

    2016-05-01

    A fully automated segmentation algorithm, progressive surface resolution (PSR), is presented in this paper to determine the closed surface of approximately convex blob-like structures that are common in biomedical imaging. The PSR algorithm was applied to the cortical surface segmentation of 460 vertebral bodies on 46 low-dose chest CT images, which can be potentially used for automated bone mineral density measurement and compression fracture detection. The target surface is realized by a closed triangular mesh, which thereby guarantees the enclosure. The surface vertices of the triangular mesh representation are constrained along radial trajectories that are uniformly distributed in 3D angle space. The segmentation is accomplished by determining for each radial trajectory the location of its intersection with the target surface. The surface is first initialized based on an input high confidence boundary image and then resolved progressively based on a dynamic attraction map in an order of decreasing degree of evidence regarding the target surface location. For the visual evaluation, the algorithm achieved acceptable segmentation for 99.35 % vertebral bodies. Quantitative evaluation was performed on 46 vertebral bodies and achieved overall mean Dice coefficient of 0.939 (with max [Formula: see text] 0.957, min [Formula: see text] 0.906 and standard deviation [Formula: see text] 0.011) using manual annotations as the ground truth. Both visual and quantitative evaluations demonstrate encouraging performance of the PSR algorithm. This novel surface resolution strategy provides uniform angular resolution for the segmented surface with computation complexity and runtime that are linearly constrained by the total number of vertices of the triangular mesh representation.

  8. A high-order vertex-based central ENO finite-volume scheme for three-dimensional compressible flows

    DOE PAGES

    Charest, Marc R.J.; Canfield, Thomas R.; Morgan, Nathaniel R.; ...

    2015-03-11

    High-order discretization methods offer the potential to reduce the computational cost associated with modeling compressible flows. However, it is difficult to obtain accurate high-order discretizations of conservation laws that do not produce spurious oscillations near discontinuities, especially on multi-dimensional unstructured meshes. A novel, high-order, central essentially non-oscillatory (CENO) finite-volume method that does not have these difficulties is proposed for tetrahedral meshes. The proposed unstructured method is vertex-based, which differs from existing cell-based CENO formulations, and uses a hybrid reconstruction procedure that switches between two different solution representations. It applies a high-order k-exact reconstruction in smooth regions and a limited linearmore » reconstruction when discontinuities are encountered. Both reconstructions use a single, central stencil for all variables, making the application of CENO to arbitrary unstructured meshes relatively straightforward. The new approach was applied to the conservation equations governing compressible flows and assessed in terms of accuracy and computational cost. For all problems considered, which included various function reconstructions and idealized flows, CENO demonstrated excellent reliability and robustness. Up to fifth-order accuracy was achieved in smooth regions and essentially non-oscillatory solutions were obtained near discontinuities. The high-order schemes were also more computationally efficient for high-accuracy solutions, i.e., they took less wall time than the lower-order schemes to achieve a desired level of error. In one particular case, it took a factor of 24 less wall-time to obtain a given level of error with the fourth-order CENO scheme than to obtain the same error with the second-order scheme.« less

  9. A new conformal absorbing boundary condition for finite element meshes and parallelization of FEMATS

    NASA Technical Reports Server (NTRS)

    Chatterjee, A.; Volakis, J. L.; Nguyen, J.; Nurnberger, M.; Ross, D.

    1993-01-01

    Some of the progress toward the development and parallelization of an improved version of the finite element code FEMATS is described. This is a finite element code for computing the scattering by arbitrarily shaped three dimensional surfaces composite scatterers. The following tasks were worked on during the report period: (1) new absorbing boundary conditions (ABC's) for truncating the finite element mesh; (2) mixed mesh termination schemes; (3) hierarchical elements and multigridding; (4) parallelization; and (5) various modeling enhancements (antenna feeds, anisotropy, and higher order GIBC).

  10. Carbon Nanotube-Based Supercapacitors with Excellent ac Line Filtering and Rate Capability via Improved Interfacial Impedance.

    PubMed

    Rangom, Yverick; Tang, Xiaowu Shirley; Nazar, Linda F

    2015-07-28

    We report the fabrication of high-performance, self-standing composite sp(2)-carbon supercapacitor electrodes using single-walled carbon nanotubes (CNTs) as conductive binder. The 3-D mesoporous mesh architecture of CNT-based composite electrodes grants unimpaired ionic transport throughout relatively thick films and allows superior performance compared to graphene-based devices at an ac line frequency of 120 Hz. Metrics of 601 μF/cm(2) with a -81° phase angle and a rate capability (RC) time constant of 199 μs are obtained for thin carbon films. The free-standing carbon films were obtained from a chlorosulfonic acid dispersion and interfaced to stainless steel current collectors with various surface treatments. CNT electrodes were able to cycle at 200 V/s and beyond, still showing a characteristic parallelepipedic cyclic votammetry shape at 1 kV/s. Current densities are measured in excess of 6400 A/g, and the electrodes retain more than 98% capacity after 1 million cycles. These promising results are attributed to a reduction of series resistance in the film through the CNT conductive network and especially to the surface treatment of the stainless steel current collector.

  11. Intersecting vane machines

    DOEpatents

    Bailey, H. Sterling; Chomyszak, Stephen M.

    2007-01-16

    The invention provides a toroidal intersecting vane machine incorporating intersecting rotors to form primary and secondary chambers whose porting configurations minimize friction and maximize efficiency. Specifically, it is an object of the invention to provide a toroidal intersecting vane machine that greatly reduces the frictional losses through meshing surfaces without the need for external gearing by modifying the function of one or the other of the rotors from that of "fluid moving" to that of "valving" thereby reducing the pressure loads and associated inefficiencies at the interface of the meshing surfaces. The inventions described herein relate to these improvements.

  12. Accuracy of methods for calculating volumetric wear from coordinate measuring machine data of retrieved metal-on-metal hip joint implants.

    PubMed

    Lu, Zhen; McKellop, Harry A

    2014-03-01

    This study compared the accuracy and sensitivity of several numerical methods employing spherical or plane triangles for calculating the volumetric wear of retrieved metal-on-metal hip joint implants from coordinate measuring machine measurements. Five methods, one using spherical triangles and four using plane triangles to represent the bearing and the best-fit surfaces, were assessed and compared on a perfect hemisphere model and a hemi-ellipsoid model (i.e. unworn models), computer-generated wear models and wear-tested femoral balls, with point spacings of 0.5, 1, 2 and 3 mm. The results showed that the algorithm (Method 1) employing spherical triangles to represent the bearing surface and to scale the mesh to the best-fit surfaces produced adequate accuracy for the wear volume with point spacings of 0.5, 1, 2 and 3 mm. The algorithms (Methods 2-4) using plane triangles to represent the bearing surface and to scale the mesh to the best-fit surface also produced accuracies that were comparable to that with spherical triangles. In contrast, if the bearing surface was represented with a mesh of plane triangles and the best-fit surface was taken as a smooth surface without discretization (Method 5), the algorithm produced much lower accuracy with a point spacing of 0.5 mm than Methods 1-4 with a point spacing of 3 mm.

  13. Applications of Space-Filling-Curves to Cartesian Methods for CFD

    NASA Technical Reports Server (NTRS)

    Aftosmis, M. J.; Murman, S. M.; Berger, M. J.

    2003-01-01

    This paper presents a variety of novel uses of space-filling-curves (SFCs) for Cartesian mesh methods in CFD. While these techniques will be demonstrated using non-body-fitted Cartesian meshes, many are applicable on general body-fitted meshes-both structured and unstructured. We demonstrate the use of single theta(N log N) SFC-based reordering to produce single-pass (theta(N)) algorithms for mesh partitioning, multigrid coarsening, and inter-mesh interpolation. The intermesh interpolation operator has many practical applications including warm starts on modified geometry, or as an inter-grid transfer operator on remeshed regions in moving-body simulations Exploiting the compact construction of these operators, we further show that these algorithms are highly amenable to parallelization. Examples using the SFC-based mesh partitioner show nearly linear speedup to 640 CPUs even when using multigrid as a smoother. Partition statistics are presented showing that the SFC partitions are, on-average, within 15% of ideal even with only around 50,000 cells in each sub-domain. The inter-mesh interpolation operator also has linear asymptotic complexity and can be used to map a solution with N unknowns to another mesh with M unknowns with theta(M + N) operations. This capability is demonstrated both on moving-body simulations and in mapping solutions to perturbed meshes for control surface deflection or finite-difference-based gradient design methods.

  14. Transabdominal preperitoneal herniorrhaphy using laser-assisted tissue soldering in a porcine model.

    PubMed

    Lanzafame, Raymond J; Soltz, Barbara A; Stadler, Istvan; Soltz, Robert

    2009-01-01

    Collagen solder is capable of fixation of surgical meshes during laparoscopic herniorrhaphy without compromising tissue integration, increasing adhesions or inflammation. This pilot study describes development of instrumentation and techniques for transabdominal preperitoneal (TAPP) herniorrhaphy using laser-assisted soldering technology. Anesthetized 20-kg to 25-kg female Yorkshire pigs underwent laparoscopy performed using a 3-trocar technique. Peritoneal incisions were made and pockets created in the preperitoneal space for mesh placement. Parietex TEC mesh segments embedded in 60% collagen-solder were soldered to the muscle surface by using a prototype laser (1.45micro, 4.5W CW, 5mm spot, and 55 degrees C set temperature) and custom laparoscopic handpiece. Parietex TEC mesh segments (Control) were affixed to the muscle with fibrin sealant (Tisseel). Peritoneal closure was with staples (Control) or by soldering collagen embedded Vicryl mesh segments over the peritoneal incision (Mesh/TAPP). Segments were inserted using a specially designed introducer. Animals were recovered and underwent second-look laparoscopy at 6 weeks postimplantation. Mesh sites were harvested after animals were euthanized. The mesh-solder constructs were easily inserted and affixed in the TAPP approach. Tisseel tended to drip during application, particularly in vertical and ventral locations. Postoperative healing was similar to Control segments in all cases. Mesh/TAPP closures healed without scarring or adhesion formation. Collagen-based tissue soldering permits normal wound healing and may mitigate or reduce use of staples for laparoscopic mesh fixation and peritoneal closure. Laser-assisted mesh fixation and peritoneal closure is a promising alternative for laparoscopic herniorrhaphy. Further development of this strategy is warranted.

  15. On a turbulent wall model to predict hemolysis numerically in medical devices

    NASA Astrophysics Data System (ADS)

    Lee, Seunghun; Chang, Minwook; Kang, Seongwon; Hur, Nahmkeon; Kim, Wonjung

    2017-11-01

    Analyzing degradation of red blood cells is very important for medical devices with blood flows. The blood shear stress has been recognized as the most dominant factor for hemolysis in medical devices. Compared to laminar flows, turbulent flows have higher shear stress values in the regions near the wall. In case of predicting hemolysis numerically, this phenomenon can require a very fine mesh and large computational resources. In order to resolve this issue, the purpose of this study is to develop a turbulent wall model to predict the hemolysis more efficiently. In order to decrease the numerical error of hemolysis prediction in a coarse grid resolution, we divided the computational domain into two regions and applied different approaches to each region. In the near-wall region with a steep velocity gradient, an analytic approach using modeled velocity profile is applied to reduce a numerical error to allow a coarse grid resolution. We adopt the Van Driest law as a model for the mean velocity profile. In a region far from the wall, a regular numerical discretization is applied. The proposed turbulent wall model is evaluated for a few turbulent flows inside a cannula and centrifugal pumps. The results present that the proposed turbulent wall model for hemolysis improves the computational efficiency significantly for engineering applications. Corresponding author.

  16. Towards a Viscous Wall Model for Immersed Boundary Methods

    NASA Technical Reports Server (NTRS)

    Brehm, Christoph; Barad, Michael F.; Kiris, Cetin C.

    2016-01-01

    Immersed boundary methods are frequently employed for simulating flows at low Reynolds numbers or for applications where viscous boundary layer effects can be neglected. The primary shortcoming of Cartesian mesh immersed boundary methods is the inability of efficiently resolving thin turbulent boundary layers in high-Reynolds number flow application. The inefficiency of resolving the thin boundary is associated with the use of constant aspect ratio Cartesian grid cells. Conventional CFD approaches can efficiently resolve the large wall normal gradients by utilizing large aspect ratio cells near the wall. This paper presents different approaches for immersed boundary methods to account for the viscous boundary layer interaction with the flow-field away from the walls. Different wall modeling approaches proposed in previous research studies are addressed and compared to a new integral boundary layer based approach. In contrast to common wall-modeling approaches that usually only utilize local flow information, the integral boundary layer based approach keeps the streamwise history of the boundary layer. This allows the method to remain effective at much larger y+ values than local wall modeling approaches. After a theoretical discussion of the different approaches, the method is applied to increasingly more challenging flow fields including fully attached, separated, and shock-induced separated (laminar and turbulent) flows.

  17. Facial expression reconstruction on the basis of selected vertices of triangle mesh

    NASA Astrophysics Data System (ADS)

    Peszor, Damian; Wojciechowska, Marzena

    2016-06-01

    Facial expression reconstruction is an important issue in the field of computer graphics. While it is relatively easy to create an animation based on meshes constructed through video recordings, this kind of high-quality data is often not transferred to another model because of lack of intermediary, anthropometry-based way to do so. However, if a high-quality mesh is sampled with sufficient density, it is possible to use obtained feature points to encode the shape of surrounding vertices in a way that can be easily transferred to another mesh with corresponding feature points. In this paper we present a method used for obtaining information for the purpose of reconstructing changes in facial surface on the basis of selected feature points.

  18. Molecular-dynamics simulations of crosslinking and confinement effects on structure, segmental mobility and mechanics of filled elastomers

    NASA Astrophysics Data System (ADS)

    Davris, Theodoros; Lyulin, Alexey V.

    2016-05-01

    The significant drop of the storage modulus under uniaxial deformation (Payne effect) restrains the performance of the elastomer-based composites and the development of possible new applications. In this paper molecular-dynamics (MD) computer simulations using LAMMPS MD package have been performed to study the mechanical properties of a coarse-grained model of this family of nanocomposite materials. Our goal is to provide simulational insights into the viscoelastic properties of filled elastomers, and try to connect the macroscopic mechanics with composite microstructure, the strength of the polymer-filler interactions and the polymer mobility at different scales. To this end we simulate random copolymer films capped between two infinite solid (filler aggregate) walls. We systematically vary the strength of the polymer-substrate adhesion interactions, degree of polymer confinement (film thickness), polymer crosslinking density, and study their influence on the equilibrium and non-equilibrium structure, segmental dynamics, and the mechanical properties of the simulated systems. The glass-transition temperature increases once the mesh size became smaller than the chain radius of gyration; otherwise it remained invariant to mesh-size variations. This increase in the glass-transition temperature was accompanied by a monotonic slowing-down of segmental dynamics on all studied length scales. This observation is attributed to the correspondingly decreased width of the bulk density layer that was obtained in films whose thickness was larger than the end-to-end distance of the bulk polymer chains. To test this hypothesis additional simulations were performed in which the crystalline walls were replaced with amorphous or rough walls.

  19. Abdominal wall reinforcement: biologic vs. degradable synthetic devices.

    PubMed

    Gruber-Blum, S; Brand, J; Keibl, C; Fortelny, R H; Redl, H; Mayer, F; Petter-Puchner, A H

    2017-04-01

    New biodegradable synthetic and biologic hernia implants have been promoted for rapid integration and tissue reinforcement in challenging repairs, e.g. at the hiatus or in contaminated wound fields. Interestingly, experimental data to support or falsify this assumption is scarce. Synthetic (BioA ® ) and biologic implants (porcine and bovine collagen matrices Strattice ® and Veritas ® ) have been tested in experimental onlay hernia repair in rats in observation periods of 30 and 60 days. The key outcome parameters were mesh integration and reinforcement of the tissue at the implant site over sutured and sealed defects as well as comparison to native abdominal wall. Macroscopic assessment, biomechanical analysis and histology with haematoxylin/eosin staining, collagen staining and van Willebrand factor staining for detection of neovascularization were performed. BioA ® was well integrated. Although the matrices were already fragmented at 60 days follow-up, hernia sites treated with synthetic scaffolds showed a significantly enhanced tissue deflection and resistance to burst force when compared to the native abdominal wall. In porcine and bovine matrices, tissue integration and shrinkage were significantly inferior to BioA ® . Histology revealed a lack of fibroblast ingrowth through mesh interstices in biologic samples, whereas BioA ® was tightly connected to the underlying tissue by reticular collagen fibres. Strattice ® and Veritas ® yielded reduced tissue integration and significant shrinkage, prohibiting further biomechanical tests. The synthetic BioA ® provides little inherent strength but reticular collagen remodelling led to an augmentation of the scar due to significantly higher burst force resistance in comparison to native tissue.

  20. Fem Formulation for Heat and Mass Transfer in Porous Medium

    NASA Astrophysics Data System (ADS)

    Azeem; Soudagar, Manzoor Elahi M.; Salman Ahmed, N. J.; Anjum Badruddin, Irfan

    2017-08-01

    Heat and mass transfer in porous medium can be modelled using three partial differential equations namely, momentum equation, energy equation and mass diffusion. These three equations are coupled to each other by some common terms that turn the whole phenomenon into a complex problem with inter-dependable variables. The current article describes the finite element formulation of heat and mass transfer in porous medium with respect to Cartesian coordinates. The problem under study is formulated into algebraic form of equations by using Galerkin's method with the help of two-node linear triangular element having three nodes. The domain is meshed with smaller sized elements near the wall region and bigger size away from walls.

  1. Simulation of Natural Convection Heat Transfer in an Inclined Square Cavity With Perfectly Conducting Side Walls Using Finite Difference Approach

    NASA Astrophysics Data System (ADS)

    Azwadi, C. S. Nor; Fairus, M. Y. Mohd

    2010-06-01

    This study is about numerical simulation of natural heat transfer inside an inclined square cavity with perfectly conducting boundary conditions for the side walls. The Navier Stokes equations were solved using finite difference approach with uniform mesh procedure. Three different inclination angels were applied and the results are presented in terms of streamlines and isotherms plots. Based on the fluid flow pattern and the isothermal lines behaviour, the convection heat transfer has shown domination over the conduction as the tilt angle increases. The simulation of natural convection inside an air filled-tilted cavity is the first time to be done to the best of our knowledge.

  2. Continuous fiber reinforced mesh bond coat for environmental barrier coating system

    DOEpatents

    Zhang, James; Das, Rupak; Roberts III, Herbert Chidsey; Delvaux, John McConnell

    2017-09-26

    A gas turbine blade may have a bond coat applied to its surface. A porous substrate may be applied to the bond layer and one or more protective layers may be applied to the bond layer such that the fiber mesh is embedded between the bond layer and the protective layer to prevent creep.

  3. Multi-Scale Surface Descriptors

    PubMed Central

    Cipriano, Gregory; Phillips, George N.; Gleicher, Michael

    2010-01-01

    Local shape descriptors compactly characterize regions of a surface, and have been applied to tasks in visualization, shape matching, and analysis. Classically, curvature has be used as a shape descriptor; however, this differential property characterizes only an infinitesimal neighborhood. In this paper, we provide shape descriptors for surface meshes designed to be multi-scale, that is, capable of characterizing regions of varying size. These descriptors capture statistically the shape of a neighborhood around a central point by fitting a quadratic surface. They therefore mimic differential curvature, are efficient to compute, and encode anisotropy. We show how simple variants of mesh operations can be used to compute the descriptors without resorting to expensive parameterizations, and additionally provide a statistical approximation for reduced computational cost. We show how these descriptors apply to a number of uses in visualization, analysis, and matching of surfaces, particularly to tasks in protein surface analysis. PMID:19834190

  4. Summary on several key techniques in 3D geological modeling.

    PubMed

    Mei, Gang

    2014-01-01

    Several key techniques in 3D geological modeling including planar mesh generation, spatial interpolation, and surface intersection are summarized in this paper. Note that these techniques are generic and widely used in various applications but play a key role in 3D geological modeling. There are two essential procedures in 3D geological modeling: the first is the simulation of geological interfaces using geometric surfaces and the second is the building of geological objects by means of various geometric computations such as the intersection of surfaces. Discrete geometric surfaces that represent geological interfaces can be generated by creating planar meshes first and then spatially interpolating; those surfaces intersect and then form volumes that represent three-dimensional geological objects such as rock bodies. In this paper, the most commonly used algorithms of the key techniques in 3D geological modeling are summarized.

  5. Adaptive unstructured triangular mesh generation and flow solvers for the Navier-Stokes equations at high Reynolds number

    NASA Technical Reports Server (NTRS)

    Ashford, Gregory A.; Powell, Kenneth G.

    1995-01-01

    A method for generating high quality unstructured triangular grids for high Reynolds number Navier-Stokes calculations about complex geometries is described. Careful attention is paid in the mesh generation process to resolving efficiently the disparate length scales which arise in these flows. First the surface mesh is constructed in a way which ensures that the geometry is faithfully represented. The volume mesh generation then proceeds in two phases thus allowing the viscous and inviscid regions of the flow to be meshed optimally. A solution-adaptive remeshing procedure which allows the mesh to adapt itself to flow features is also described. The procedure for tracking wakes and refinement criteria appropriate for shock detection are described. Although at present it has only been implemented in two dimensions, the grid generation process has been designed with the extension to three dimensions in mind. An implicit, higher-order, upwind method is also presented for computing compressible turbulent flows on these meshes. Two recently developed one-equation turbulence models have been implemented to simulate the effects of the fluid turbulence. Results for flow about a RAE 2822 airfoil and a Douglas three-element airfoil are presented which clearly show the improved resolution obtainable.

  6. Automated crack detection in conductive smart-concrete structures using a resistor mesh model

    NASA Astrophysics Data System (ADS)

    Downey, Austin; D'Alessandro, Antonella; Ubertini, Filippo; Laflamme, Simon

    2018-03-01

    Various nondestructive evaluation techniques are currently used to automatically detect and monitor cracks in concrete infrastructure. However, these methods often lack the scalability and cost-effectiveness over large geometries. A solution is the use of self-sensing carbon-doped cementitious materials. These self-sensing materials are capable of providing a measurable change in electrical output that can be related to their damage state. Previous work by the authors showed that a resistor mesh model could be used to track damage in structural components fabricated from electrically conductive concrete, where damage was located through the identification of high resistance value resistors in a resistor mesh model. In this work, an automated damage detection strategy that works through placing high value resistors into the previously developed resistor mesh model using a sequential Monte Carlo method is introduced. Here, high value resistors are used to mimic the internal condition of damaged cementitious specimens. The proposed automated damage detection method is experimentally validated using a 500 × 500 × 50 mm3 reinforced cement paste plate doped with multi-walled carbon nanotubes exposed to 100 identical impact tests. Results demonstrate that the proposed Monte Carlo method is capable of detecting and localizing the most prominent damage in a structure, demonstrating that automated damage detection in smart-concrete structures is a promising strategy for real-time structural health monitoring of civil infrastructure.

  7. Analysis of solid particles falling down and interacting in a channel with sedimentation using fictitious boundary method

    NASA Astrophysics Data System (ADS)

    Usman, K.; Walayat, K.; Mahmood, R.; Kousar, N.

    2018-06-01

    We have examined the behavior of solid particles in particulate flows. The interaction of particles with each other and with the fluid is analyzed. Solid particles can move freely through a fixed computational mesh using an Eulerian approach. Fictitious boundary method (FBM) is used for treating the interaction between particles and the fluid. Hydrodynamic forces acting on the particle's surface are calculated using an explicit volume integral approach. A collision model proposed by Glowinski, Singh, Joseph and coauthors is used to handle particle-wall and particle-particle interactions. The particulate flow is computed using multigrid finite element solver FEATFLOW. Numerical experiments are performed considering two particles falling and colliding and sedimentation of many particles while interacting with each other. Results for these experiments are presented and compared with the reference values. Effects of the particle-particle interaction on the motion of the particles and on the physical behavior of the fluid-particle system has been analyzed.

  8. Euler technology assessment for preliminary aircraft design employing OVERFLOW code with multiblock structured-grid method

    NASA Technical Reports Server (NTRS)

    Treiber, David A.; Muilenburg, Dennis A.

    1995-01-01

    The viability of applying a state-of-the-art Euler code to calculate the aerodynamic forces and moments through maximum lift coefficient for a generic sharp-edge configuration is assessed. The OVERFLOW code, a method employing overset (Chimera) grids, was used to conduct mesh refinement studies, a wind-tunnel wall sensitivity study, and a 22-run computational matrix of flow conditions, including sideslip runs and geometry variations. The subject configuration was a generic wing-body-tail geometry with chined forebody, swept wing leading-edge, and deflected part-span leading-edge flap. The analysis showed that the Euler method is adequate for capturing some of the non-linear aerodynamic effects resulting from leading-edge and forebody vortices produced at high angle-of-attack through C(sub Lmax). Computed forces and moments, as well as surface pressures, match well enough useful preliminary design information to be extracted. Vortex burst effects and vortex interactions with the configuration are also investigated.

  9. Liquid-Gas-Like Phase Transition in Sand Flow Under Microgravity

    NASA Astrophysics Data System (ADS)

    Huang, Yu; Zhu, Chongqiang; Xiang, Xiang; Mao, Wuwei

    2015-06-01

    In previous studies of granular flow, it has been found that gravity plays a compacting role, causing convection and stratification by density. However, there is a lack of research and analysis of the characteristics of different particles' motion under normal gravity contrary to microgravity. In this paper, we conduct model experiments on sand flow using a model test system based on a drop tower under microgravity, within which the characteristics and development processes of granular flow under microgravity are captured by high-speed cameras. The configurations of granular flow are simulated using a modified MPS (moving particle simulation), which is a mesh-free, pure Lagrangian method. Moreover, liquid-gas-like phase transitions in the sand flow under microgravity, including the transitions to "escaped", "jumping", and "scattered" particles are highlighted, and their effects on the weakening of shear resistance, enhancement of fluidization, and changes in particle-wall and particle-particle contact mode are analyzed. This study could help explain the surface geology evolution of small solar bodies and elucidate the nature of granular interaction.

  10. Patient-specific blood flow simulation to improve intracranial aneurysm diagnosis

    NASA Astrophysics Data System (ADS)

    Fenz, Wolfgang; Dirnberger, Johannes

    2011-03-01

    We present a novel simulation system of blood flow through intracranial aneurysms including the interaction between blood lumen and vessel tissue. It provides the means to estimate rupture risks by calculating the distribution of pressure and shear stresses in the aneurysm, in order to support the planning of clinical interventions. So far, this has only been possible with commercial simulation packages originally targeted at industrial applications, whereas our implementation focuses on the intuitive integration into clinical workflow. Due to the time-critical nature of the application, we exploit most efficient state-of-the-art numerical methods and technologies together with high performance computing infrastructures (Austrian Grid). Our system builds a three-dimensional virtual replica of the patient's cerebrovascular system from X-ray angiography, CT or MR images. The physician can then select a region of interest which is automatically transformed into a tetrahedral mesh. The differential equations for the blood flow and the wall elasticity are discretized via the finite element method (FEM), and the resulting linear equation systems are handled by an algebraic multigrid (AMG) solver. The wall displacement caused by the blood pressure is calculated using an iterative fluid-structure interaction (FSI) algorithm, and the fluid mesh is deformed accordingly. First simulation results on measured patient geometries show good medical relevance for diagnostic decision support.

  11. A consistent and conservative scheme for MHD flows with complex boundaries on an unstructured Cartesian adaptive system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Jie; Ni, Ming-Jiu, E-mail: mjni@ucas.ac.cn

    2014-01-01

    The numerical simulation of Magnetohydrodynamics (MHD) flows with complex boundaries has been a topic of great interest in the development of a fusion reactor blanket for the difficulty to accurately simulate the Hartmann layers and side layers along arbitrary geometries. An adaptive version of a consistent and conservative scheme has been developed for simulating the MHD flows. Besides, the present study forms the first attempt to apply the cut-cell approach for irregular wall-bounded MHD flows, which is more flexible and conveniently implemented under adaptive mesh refinement (AMR) technique. It employs a Volume-of-Fluid (VOF) approach to represent the fluid–conducting wall interfacemore » that makes it possible to solve the fluid–solid coupling magnetic problems, emphasizing at how electric field solver is implemented when conductivity is discontinuous in cut-cell. For the irregular cut-cells, the conservative interpolation technique is applied to calculate the Lorentz force at cell-center. On the other hand, it will be shown how consistent and conservative scheme is implemented on fine/coarse mesh boundaries when using AMR technique. Then, the applied numerical schemes are validated by five test simulations and excellent agreement was obtained for all the cases considered, simultaneously showed good consistency and conservative properties.« less

  12. Wall modeled LES of wind turbine wakes with geometrical effects

    NASA Astrophysics Data System (ADS)

    Bricteux, Laurent; Benard, Pierre; Zeoli, Stephanie; Moureau, Vincent; Lartigue, Ghislain; Vire, Axelle

    2017-11-01

    This study focuses on prediction of wind turbine wakes when geometrical effects such as nacelle, tower, and built environment, are taken into account. The aim is to demonstrate the ability of a high order unstructured solver called YALES2 to perform wall modeled LES of wind turbine wake turbulence. The wind turbine rotor is modeled using an Actuator Line Model (ALM) while the geometrical details are explicitly meshed thanks to the use of an unstructured grid. As high Reynolds number flows are considered, sub-grid scale models as well as wall modeling are required. The first test case investigated concerns a wind turbine flow located in a wind tunnel that allows to validate the proposed methodology using experimental data. The second test case concerns the simulation of a wind turbine wake in a complex environment (e.g. a Building) using realistic turbulent inflow conditions.

  13. Fictitious domain method for fully resolved reacting gas-solid flow simulation

    NASA Astrophysics Data System (ADS)

    Zhang, Longhui; Liu, Kai; You, Changfu

    2015-10-01

    Fully resolved simulation (FRS) for gas-solid multiphase flow considers solid objects as finite sized regions in flow fields and their behaviours are predicted by solving equations in both fluid and solid regions directly. Fixed mesh numerical methods, such as fictitious domain method, are preferred in solving FRS problems and have been widely researched. However, for reacting gas-solid flows no suitable fictitious domain numerical method has been developed. This work presents a new fictitious domain finite element method for FRS of reacting particulate flows. Low Mach number reacting flow governing equations are solved sequentially on a regular background mesh. Particles are immersed in the mesh and driven by their surface forces and torques integrated on immersed interfaces. Additional treatments on energy and surface reactions are developed. Several numerical test cases validated the method and a burning carbon particles array falling simulation proved the capability for solving moving reacting particle cluster problems.

  14. Transfer impedance measurements of the space shuttle Solid Rocket Motor (SRM) joints, wire meshes and a carbon graphite motor case

    NASA Technical Reports Server (NTRS)

    Papazian, Peter B.; Perala, Rodney A.; Curry, John D.; Lankford, Alan B.; Keller, J. David

    1988-01-01

    Using three different current injection methods and a simple voltage probe, transfer impedances for Solid Rocket Motor (SRM) joints, wire meshes, aluminum foil, Thorstrand and a graphite composite motor case were measured. In all cases, the surface current distribution for the particular current injection device was calculated analytically or by finite difference methods. The results of these calculations were used to generate a geometric factor which was the ratio of total injected current to surface current density. The results were validated in several ways. For wire mesh measurements, results showed good agreement with calculated results for a 14 by 18 Al screen. SRM joint impedances were independently verified. The filiment wound case measurement results were validated only to the extent that their curve shape agrees with the expected form of transfer impedance for a homogeneous slab excited by a plane wave source.

  15. Surface micromachined counter-meshing gears discrimination device

    DOEpatents

    Polosky, Marc A.; Garcia, Ernest J.; Allen, James J.

    2000-12-12

    A surface micromachined Counter-Meshing Gears (CMG) discrimination device which functions as a mechanically coded lock. Each of two CMG has a first portion of its perimeter devoted to continuous driving teeth that mesh with respective pinion gears. Each EMG also has a second portion of its perimeter devoted to regularly spaced discrimination gear teeth that extend outwardly on at least one of three levels of the CMG. The discrimination gear teeth are designed so as to pass each other without interference only if the correct sequence of partial rotations of the CMG occurs in response to a coded series of rotations from the pinion gears. A 24 bit code is normally input to unlock the device. Once unlocked, the device provides a path for an energy or information signal to pass through the device. The device is designed to immediately lock up if any portion of the 24 bit code is incorrect.

  16. Optical properties of flexible fluorescent films prepared by screen printing technology

    NASA Astrophysics Data System (ADS)

    Chen, Yan; Ke, Taiyan; Chen, Shuijin; He, Xin; Zhang, Mei; Li, Dong; Deng, Jinfeng; Zeng, Qingguang

    2018-05-01

    In this work, we prepared a fluorescent film comprised phosphors and silicone on flexible polyethylene terephthalate (PET) substrate using a screen printing technology. The effects of mesh number and weight ratio of phosphors to silicone on the optical properties of the flexible films were investigated. The results indicate that the emission intensity of the film increase as the mesh decreased from 400 to 200, but the film surface gradually becomes uneven. The fluorescent film with high emission intensity and smooth surface can be obtained when the weight ratio of phosphor to gel is 2:1, and mesh number is 300. The luminous efficiency of the fabricated LEDs combined the fluorescent films with 460 nm Ga(In)N chip module can reach 75 lm/W. The investigation indicates that the approach can be applied in the remote fluorescent film conversion and decreases the requirements of the particle size and the dispersion state of fluorescent materials.

  17. Characterizing the effects of cladding on semi-elliptical longitudinal surface flaws in cylindrical vessels subjected to internal pressure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Killian, D.E.; Yoon, K.K.

    1996-12-01

    Flaws on the inside surface of cladded reactor vessels are often analyzed by modelling the carbon steel base metal without consideration of a layer of stainless steel cladding material, thus ignoring the effects of this bimetallic discontinuity. Adding cladding material to the inside surface of a finite element model of a vessel raises concerns regarding adequate mesh refinement in the vicinity of the base metal/cladding interface. This paper presents results of three-dimensional linear stress analysis that has been performed to obtain stress intensity factors for clad and unclad reactor vessels subjected to internal pressure loading. The study concentrates on semi-ellipticalmore » longitudinal surface flaws with a 6 to 1 length-to-depth ratio and flaw depths of 1/8 and 1/4 of the base metal thickness. Various meshing schemes are evaluated for modelling the crack front profile, with particular emphasis on the region near the inside surface and at the base metal/cladding interface. The shape of the crack front profile through the cladding layer and the number of finite elements used to discretize the cladding thickness are found to have a significant influence on typical fracture mechanic measures of the crack tip stress fields. Results suggest that the stress intensity factor at the inner surface of a cladded vessel may be affected as much by the finite element mesh near the surface as by the material discontinuity between the two parts of the structure.« less

  18. Radiation Coupling with the FUN3D Unstructured-Grid CFD Code

    NASA Technical Reports Server (NTRS)

    Wood, William A.

    2012-01-01

    The HARA radiation code is fully-coupled to the FUN3D unstructured-grid CFD code for the purpose of simulating high-energy hypersonic flows. The radiation energy source terms and surface heat transfer, under the tangent slab approximation, are included within the fluid dynamic ow solver. The Fire II flight test, at the Mach-31 1643-second trajectory point, is used as a demonstration case. Comparisons are made with an existing structured-grid capability, the LAURA/HARA coupling. The radiative surface heat transfer rates from the present approach match the benchmark values within 6%. Although radiation coupling is the focus of the present work, convective surface heat transfer rates are also reported, and are seen to vary depending upon the choice of mesh connectivity and FUN3D ux reconstruction algorithm. On a tetrahedral-element mesh the convective heating matches the benchmark at the stagnation point, but under-predicts by 15% on the Fire II shoulder. Conversely, on a mixed-element mesh the convective heating over-predicts at the stagnation point by 20%, but matches the benchmark away from the stagnation region.

  19. Options for Closure of the Infected Abdomen

    PubMed Central

    Campbell, Chris A.; Rosenberger, Laura H.; Politano, Amani D.; Davies, Stephen W.; Riccio, Lin M.; Sawyer, Robert G.

    2012-01-01

    Abstract Background The infected abdomen poses substantial challenges to surgeons, and often, both temporary and definitive closure techniques are required. We reviewed the options available to close the abdominal wall defect encountered frequently during and after the management of complicated intra-abdominal infections. Methods A comprehensive review was performed of the techniques and literature on abdominal closure in the setting of intra-abdominal infection. Results Temporary abdominal closure options include the Wittmann Patch, Bogota bag, vacuum-assisted closure (VAC), the AbThera™ device, and synthetic or biologic mesh. Definitive reconstruction has been described with mesh, components separation, and autologous tissue transfer. Conclusion Reconstructing the infected abdomen, both temporarily and definitively, can be accomplished with various techniques, each of which is associated with unique advantages and disadvantages. Appropriate judgment is required to optimize surgical outcomes in these complex cases. PMID:23216525

  20. Multigrid solution of compressible turbulent flow on unstructured meshes using a two-equation model

    NASA Technical Reports Server (NTRS)

    Mavriplis, D. J.; Matinelli, L.

    1994-01-01

    The steady state solution of the system of equations consisting of the full Navier-Stokes equations and two turbulence equations has been obtained using a multigrid strategy of unstructured meshes. The flow equations and turbulence equations are solved in a loosely coupled manner. The flow equations are advanced in time using a multistage Runge-Kutta time-stepping scheme with a stability-bound local time step, while turbulence equations are advanced in a point-implicit scheme with a time step which guarantees stability and positivity. Low-Reynolds-number modifications to the original two-equation model are incorporated in a manner which results in well-behaved equations for arbitrarily small wall distances. A variety of aerodynamic flows are solved, initializing all quantities with uniform freestream values. Rapid and uniform convergence rates for the flow and turbulence equations are observed.

Top