Sample records for washer gun sources

  1. Development of ion source with a washer gun for pulsed neutral beam injection.

    PubMed

    Asai, T; Yamaguchi, N; Kajiya, H; Takahashi, T; Imanaka, H; Takase, Y; Ono, Y; Sato, K N

    2008-06-01

    A new type of economical neutral beam source has been developed by using a single washer gun, pulsed operation, and a simple electrode system. We replaced the conventional hot filaments for arc-discharge-type plasma formation with a single stainless-steel washer gun, eliminating the entire dc power supply for the filaments and the cooling system for the electrodes. Our initial experiments revealed successful beam extraction up to 10 kV and 8.6 A, based on spatial profile measurements of density and temperature in the plasma source. The system also shows the potential to control the beam profile by controlling the plasma parameters in the ion accumulation chamber.

  2. Development of a low-energy and high-current pulsed neutral beam injector with a washer-gun plasma source for high-beta plasma experiments.

    PubMed

    Ii, Toru; Gi, Keii; Umezawa, Toshiyuki; Asai, Tomohiko; Inomoto, Michiaki; Ono, Yasushi

    2012-08-01

    We have developed a novel and economical neutral-beam injection system by employing a washer-gun plasma source. It provides a low-cost and maintenance-free ion beam, thus eliminating the need for the filaments and water-cooling systems employed conventionally. In our primary experiments, the washer gun produced a source plasma with an electron temperature of approximately 5 eV and an electron density of 5 × 10(17) m(-3), i.e., conditions suitable for ion-beam extraction. The dependence of the extracted beam current on the acceleration voltage is consistent with space-charge current limitation, because the observed current density is almost proportional to the 3/2 power of the acceleration voltage below approximately 8 kV. By optimizing plasma formation, we successfully achieved beam extraction of up to 40 A at 15 kV and a pulse length in excess of 0.25 ms. Its low-voltage and high-current pulsed-beam properties enable us to apply this high-power neutral beam injection into a high-beta compact torus plasma characterized by a low magnetic field.

  3. Development of neutral beam injection system by use of washer gun plasma source

    NASA Astrophysics Data System (ADS)

    Imanaka, Heizo; Kajiya, Hirotaka; Nemoto, Yuichi; Azuma, Akiyoshi; Asai, Tomoaki; Yamada, Takuma; Inomoto, Michiaki; Ono, Yasushi

    2008-11-01

    For the past ten years, we have been investigating high-beta Spherical Tokamaks (ST) formation using reconnection heating of their axial merging in the TS-4 experiment, University of Tokyo. The produced ST was observed to have the maximum beta of 50-60% right after the merging of two STs. A key issue after the formation is to maintain the produced high-beta ST over 100 Alfven times for its stability check. A new low-cost pulsed neutral beam injection (NBI) system has been arranged for its sustainment experiment. Its advantages are 1) low voltage (15kV for low-field side of ST) and high current (20A), 2) maintenance-free, 3) low-cost. The conventional filament plasma source was replaced by the washer gun to realize air-cooled and maintenance free NBI system. In its startup experiment, we already extracted the maximum beam current of 3.7A for then acceleration voltage of 10kV successfully. This result suggests that the increase in the acceleration voltage and several conditioning work will realize its designed beam parameters of 15kV, 20A.

  4. Characterization of a medium-sized washer-gun for an axisymmetric mirror

    NASA Astrophysics Data System (ADS)

    Yi, Hongshen; Liu, Ming; Shi, Peiyun; Yang, Zhida; Zhu, Guanghui; Lu, Quanming; Sun, Xuan

    2018-04-01

    A new medium-sized washer gun is developed for a plasma start-up in a fully axisymmetric mirror. The gun is positioned at the east end of the Keda Mirror with AXisymmetricity facility and operated in the pulsed mode with an arc discharging time of 1.2 ms and a typical arc current of 8.5 kA with 1.5 kV discharge voltage. To optimize the operation, a systematic scan of the neutral pressure, the arc voltage, the bias voltage on a mesh grid 6 cm in front of the gun and an end electrode located on the west end of mirror, and the mirror ratio was performed. The streaming plasma was measured with triple probes in the three mirror cells and a diamagnetic loop in the central cell. Floating potential measurements suggest that the plasma could be divided into streaming and mirror-confined plasmas. The floating potential for the streaming plasma is negative, with an electric field pointing inwards. The mirror-confined plasma has a typical lifetime of 0.5 ms.

  5. Characterization of a medium-sized washer-gun for an axisymmetric mirror.

    PubMed

    Yi, Hongshen; Liu, Ming; Shi, Peiyun; Yang, Zhida; Zhu, Guanghui; Lu, Quanming; Sun, Xuan

    2018-04-01

    A new medium-sized washer gun is developed for a plasma start-up in a fully axisymmetric mirror. The gun is positioned at the east end of the Keda Mirror with AXisymmetricity facility and operated in the pulsed mode with an arc discharging time of 1.2 ms and a typical arc current of 8.5 kA with 1.5 kV discharge voltage. To optimize the operation, a systematic scan of the neutral pressure, the arc voltage, the bias voltage on a mesh grid 6 cm in front of the gun and an end electrode located on the west end of mirror, and the mirror ratio was performed. The streaming plasma was measured with triple probes in the three mirror cells and a diamagnetic loop in the central cell. Floating potential measurements suggest that the plasma could be divided into streaming and mirror-confined plasmas. The floating potential for the streaming plasma is negative, with an electric field pointing inwards. The mirror-confined plasma has a typical lifetime of 0.5 ms.

  6. Automobile windshield washer fluid: A potential source of transmission for Legionella.

    PubMed

    Schwake, David Otto; Alum, Absar; Abbaszadegan, Morteza

    2015-09-01

    Epidemiological evidence suggesting driving cars to be a risk factor for legionellosis has prompted public health studies to investigate vehicle windshield washer fluid as a novel transmission source of this disease. The goal of the current study was to investigate whether or not windshield washer fluid could serve as a potential source of transmission for Legionella. A wide variation in the survival of L. pneumophila was observed when incubated in different washer fluids at 25 and 37 °C, however, one brand tested supported Legionella survival similar to or greater than sterilized deionized water. In addition, 1 L of tap water contained in a washer fluid reservoir was able to support population growth and survival of Legionella for several months. In a field study examining the windshield washer fluid of 12 elementary school buses, Legionella were detected from 84% of samples at a high concentration of 8.1×10(4) CFU/mL. Culturable cells were also detected in aerosolized washer fluid during washer fluid spray. By demonstrating survival in certain windshield washer fluids, growth within washer fluid reservoirs, and the presence of viable cells in bus washer fluid spray, we have provided evidence suggesting the potential for a novel route of Legionella exposure. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. ECR ion source with electron gun

    DOEpatents

    Xie, Z.Q.; Lyneis, C.M.

    1993-10-26

    An Advanced Electron Cyclotron Resonance ion source having an electron gun for introducing electrons into the plasma chamber of the ion source is described. The ion source has a injection enclosure and a plasma chamber tank. The plasma chamber is defined by a plurality of longitudinal magnets. The electron gun injects electrons axially into the plasma chamber such that ionization within the plasma chamber occurs in the presence of the additional electrons produced by the electron gun. The electron gun has a cathode for emitting electrons therefrom which is heated by current supplied from an AC power supply while bias potential is provided by a bias power supply. A concentric inner conductor and outer conductor carry heating current to a carbon chuck and carbon pusher which hold the cathode in place and also heat the cathode. In the Advanced Electron Cyclotron Resonance ion source, the electron gun replaces the conventional first stage used in prior electron cyclotron resonance ion generators. 5 figures.

  8. ECR ion source with electron gun

    DOEpatents

    Xie, Zu Q.; Lyneis, Claude M.

    1993-01-01

    An Advanced Electron Cyclotron Resonance ion source (10) having an electron gun (52) for introducing electrons into the plasma chamber (18) of the ion source (10). The ion source (10) has a injection enclosure (12) and a plasma chamber tank (14). The plasma chamber (18) is defined by a plurality of longitudinal magnets (16). The electron gun (52) injects electrons axially into the plasma chamber (18) such that ionization within the plasma chamber (18) occurs in the presence of the additional electrons produced by the electron gun (52). The electron gun (52) has a cathode (116) for emitting electrons therefrom which is heated by current supplied from an AC power supply (96) while bias potential is provided by a bias power supply (118). A concentric inner conductor (60) and Outer conductor (62) carry heating current to a carbon chuck (104) and carbon pusher (114) Which hold the cathode (116) in place and also heat the cathode (16). In the Advanced Electron Cyclotron Resonance ion source (10), the electron gun (52) replaces the conventional first stage used in prior art electron cyclotron resonance ion generators.

  9. Gun Violence Following Inpatient Psychiatric Treatment: Offense Characteristics, Sources of Guns, and Number of Victims.

    PubMed

    Kivisto, Aaron J

    2017-10-01

    This study presents data on the relative contribution to gun violence by people with a history of inpatient psychiatric treatment and on federal efforts to deter presumptively dangerous persons from obtaining firearms, information useful for analyzing the potential public health benefits of gun policies targeting people with serious mental illness. The study also estimates the reduction in gun violence victims that would be expected if individuals with a previous psychiatric hospitalization were prohibited from purchasing firearms. Data from 838 violent gun offenders from a nationally representative sample of state prison inmates were analyzed. Those with and without a history of psychiatric hospitalization were compared on a range of offense characteristics, including relationship to the victim, number of victims, location of the offense, and source of firearms. Inmates with a history of hospitalization constituted 12% of all violent gun offenders and accounted for 13% of the sample's victims. They were less likely than those without a previous hospitalization to victimize strangers (odds ratio=.52) and were no more likely to commit gun violence in public or to have multiple victims. Among those with previous hospitalizations, 78% obtained guns from sources not subject to federal background checks. Of the total 1,041 victims of gun violence, only 3% were victimized by participants with a history of hospitalization who obtained guns from currently regulated sources. Prohibiting all individuals with a history of psychiatric hospitalization from purchasing firearms, absent expanded background checks, was estimated to reduce the number of gun violence victims by only 3%.

  10. High Current, High Density Arc Plasma as a New Source for WiPAL

    NASA Astrophysics Data System (ADS)

    Waleffe, Roger; Endrizzi, Doug; Myers, Rachel; Wallace, John; Clark, Mike; Forest, Cary; WiPAL Team

    2016-10-01

    The Wisconsin Plasma Astrophysics Lab (WiPAL) has installed a new array of nineteen plasma sources (plasma guns) on its 3 m diameter, spherical vacuum vessel. Each gun is a cylindrical, molybdenum, washer-stabilized, arc plasma source. During discharge, the guns are maintained at 1.2 kA across 100 V for 10 ms by the gun power supply establishing a high density plasma. Each plasma source is fired independently allowing for adjustable plasma parameters, with densities varying between 1018 -1019 m-3 and electron temperatures of 5-15 eV. Measurements were characterized using a 16 tip Langmuir probe. The plasma source will be used as a background plasma for the magnetized coaxial plasma gun (MCPG), the Terrestrial Reconnection Experiment (TREX), and as the plasma source for a magnetic mirror experiment. Temperature, density, and confinement results will be presented. This work is supported by the DoE and the NSF.

  11. A NEW THERMIONIC RF ELECTRON GUN FOR SYNCHROTRON LIGHT SOURCES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kutsaev, Sergey; Agustsson, R.; Hartzell, J

    A thermionic RF gun is a compact and efficient source of electrons used in many practical applications. RadiaBeam Systems and the Advanced Photon Source at Argonne National Laboratory collaborate in developing of a reliable and robust thermionic RF gun for synchrotron light sources which would offer substantial improvements over existing thermionic RF guns and allow stable operation with up to 1A of beam peak current at a 100 Hz pulse repetition rate and a 1.5 μs RF pulse length. In this paper, we discuss the electromagnetic and engineering design of the cavity and report the progress towards high power testsmore » of the cathode assembly of the new gun.« less

  12. Bern clothes washer study. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tomlinson, J.J.; Rizy, D.T.

    1998-03-01

    The US market for domestic clothes washers is currently dominated by conventional, vertical axis washers, which typically require about 40 gallons of water for each load. Although small for an individual load, the fact that 35 billion loads of laundry are washed annually in the US results in a substantial quantity of water and energy use. Although much smaller, today`s market for high-efficiency clothes washers which use much less water and energy is growing albeit slowly as manufacturers are making washers based around tumble-action, horizontal axis designs available, information about their performance and benefits is being developed, and consumers aremore » made aware of these benefits. To help build awareness of these benefits and to accelerate markets for high-efficiency washers, DOE, under its Energy Star Program and in cooperation with Maytag Appliances, conducted a field-evaluation of high-efficiency washers using Bern, Kansas (population approximately 200) as a test bed. Baseline washer performance data as well as customer washing behavior were obtained from data collected on the existing washers of more than 100 participants in this instrumented study. Following a 2-month initial study period, all conventional washers were replaced by high-efficiency, tumble action washers, and the experiment continued for another 3-month period. Based on measured data from over 20,000 loads of laundry, the impact of the washer replacement on (1) individual customers` energy and water consumption, (2) customers` laundry habits and perceptions, and (3) the community`s water supply and waste water systems were determined and reported.« less

  13. Self-contained hot-hollow cathode gun source assembly

    DOEpatents

    Zeren, Joseph D.

    1986-01-01

    A self-contained hot-hollow cathode gun source assembly for use in a vacuum chamber includes a crucible block having a hot-hollow cathode gun mounted underneath and providing a hole for the magnetic deflection of the ion/electron beam into a crucible on top the block.

  14. Self-contained hot-hollow cathode gun source assembly

    DOEpatents

    Zeren, J.D.

    1984-08-01

    A self-contained hot-hollow cathode gun source assembly for use in a vacuum chamber includes a crucible block having a hot-hollow cathode gun mounted underneath and providing a hole for the magnetic deflection of the ion/electron beam into a crucible on top the block.

  15. Unitized Nut-and-Washer Assembly

    NASA Technical Reports Server (NTRS)

    Rossi, P. J.

    1986-01-01

    Combination nut, washer, and lockwasher secures parts quickly without damaging metal finishes. Nut and lockwasher are captured by bent tabs of flat washer in this concept for unified fastener. Optional perforated tab on flat washer allows easy tagging and storage. Fastener intended for attaching leads and buses to studs on electronic equipment.

  16. Development of plasma sources for ICRF heating experiment in KMAX mirror device

    NASA Astrophysics Data System (ADS)

    Sun, Xuan; Liu, Ming; Yi, Hongshen; Lin, Munan; Shi, Peiyun

    2016-10-01

    KMAX, Keda Mirror with AXisymmeticity, is a tandem mirror machine with a length of 10 meters and diameters of 1.2 meters in the central cell and 0.3 meters in the mirror throat. In the past experiments, the plasma was generated by helicon wave launched from the west end. We obtained the blue core mode in argon discharge, however, it cannot provide sufficient plasma for hydrogen discharge, which is at least 1012 cm-3 required for effective ICRF heating. Several attempts have thus been tried or under design to increase the central cell's plasma density: (1) a washer gun with aperture of 1cm has been successfully tested, and a plasma density of 1013 cm-3 was achieved in the west cell near the gun, however, the plasma is only 1011 cm-3 in the central cell possible due to the mirror trapping and/or neutral quenching effect (2) a larger washer gun with aperture of 2.5 cm and a higher power capacitor bank are being assembled in order to generate more plasmas. In addition, how to mitigate the neutrals is under consideration (3) A hot cathode is been designed and will be tested in combination with plasma gun or alone. Preliminary results from those plasma sources will be presented and discussed.

  17. Water gun vs air gun: A comparison

    USGS Publications Warehouse

    Hutchinson, D.R.; Detrick, R. S.

    1984-01-01

    The water gun is a relatively new marine seismic sound source that produces an acoustic signal by an implosive rather than explosive mechanism. A comparison of the source characteristics of two different-sized water guns with those of conventional air guns shows the the water gun signature is cleaner and much shorter than that of a comparable-sized air gun: about 60-100 milliseconds (ms) for an 80-in3. (1.31-liter (I)) water gun compared with several hundred ms for an 80-in3. (1.31-1) air gun. The source spectra of water guns are richer in high frequencies (>200 Hz) than are those of air guns, but they also have less energy than those of air guns at low frequencies. A comparison between water gun and air gun reflection profiles in both shallow (Long Island Sound)-and deep (western Bermuda Rise)-water settings suggests that the water gun offers a good compromise between very high resolution, limited penetration systems (e.g. 3.5-kHz profilers and sparkers) and the large volume air guns and tuned air gun arrays generally used where significant penetration is required. ?? 1984 D. Reidel Publishing Company.

  18. 21 CFR 880.6991 - Medical washer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical washer. 880.6991 Section 880.6991 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES....6991 Medical washer. (a) Identification. A medical washer is a device that is intended for general...

  19. 21 CFR 880.6991 - Medical washer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Medical washer. 880.6991 Section 880.6991 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES....6991 Medical washer. (a) Identification. A medical washer is a device that is intended for general...

  20. 21 CFR 880.6991 - Medical washer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical washer. 880.6991 Section 880.6991 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES....6991 Medical washer. (a) Identification. A medical washer is a device that is intended for general...

  1. 21 CFR 880.6991 - Medical washer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical washer. 880.6991 Section 880.6991 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES....6991 Medical washer. (a) Identification. A medical washer is a device that is intended for general...

  2. 21 CFR 880.6991 - Medical washer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical washer. 880.6991 Section 880.6991 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES....6991 Medical washer. (a) Identification. A medical washer is a device that is intended for general...

  3. 10 CFR 431.152 - Definitions concerning commercial clothes washers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Definitions concerning commercial clothes washers. 431.152... clothes washers. Commercial clothes washer means a soft-mounted front-loading or soft-mounted top-loading clothes washer that— (1) Has a clothes container compartment that— (i) For horizontal-axis clothes washers...

  4. Laboratory testing of clothes washers. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dieckmann, J.; Murphy, W.

    1995-12-01

    Horizontal axis (H-axis) clothes washers use less water and energy than conventional top-loading vertical axis (V-axis) clothes washers, yet sales in the US are insignificant. In the High Efficiency Laundry Metering and Market Analysis (THELMA) project, EPRI and a group of utilities have pooled their resources to develop the basis for successful DSM programs to accelerate the acceptance of this technology in the US market. This report covers the laboratory test phase of the THELMA project. The objective of this effort was to measure the performance of a representative sample of currently manufactured H-axis washers and to compare this performancemore » to that of a typical V-axis washer. Several aspects of performance were measured, with the emphasis on measures of energy consumption and water consumption: DOE washer capacity; Hot and cold water consumption; Energy consumption by the washer mechanical drive; DOE energy factor; Water extraction effectiveness; Effect of water extraction effectiveness on dryer energy; Soil removal effectiveness; Rinsing effectiveness and Gentleness of action. Six H-axis washers, provided by US or European manufacturers, were tested. Test results varied over a range for these six machines, but on average, the H-axis washers used 40% less energy (normalized to basket volume) and 25% less water (normalized to basket volume) when measured according to the DOE test procedure.« less

  5. Sources of guns to dangerous people: what we learn by asking them.

    PubMed

    Cook, Philip J; Parker, Susan T; Pollack, Harold A

    2015-10-01

    Gun violence exacts a lethal toll on public health. This paper focuses on reducing access to firearms by dangerous offenders, contributing original empirical data on the gun transactions that arm offenders in Chicago. Conducted in the fall of 2013, analysis of an open-ended survey of 99 inmates of Cook County Jail focuses on a subset of violence-prone individuals with the goal of improving law enforcement actions. Among our principal findings: *Our respondents (adult offenders living in Chicago or nearby) obtain most of their guns from their social network of personal connections. Rarely is the proximate source either direct purchase from a gun store, or theft. *Only about 60% of guns in the possession of respondents were obtained by purchase or trade. Other common arrangements include sharing guns and holding guns for others. *About one in seven respondents report selling guns, but in only a few cases as a regular source of income. *Gangs continue to play some role in Chicago in organizing gun buys and in distributing guns to members as needed. *The Chicago Police Department has a considerable effect on the workings of the underground gun market through deterrence. Transactions with strangers and less-trusted associates are limited by concerns over arrest risk (if the buyer should happen to be an undercover officer or a snitch), and about being caught with a "dirty" gun (one that has been fired in a crime). Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Self-locking washer and method of use

    DOEpatents

    Vodila, James M.; Huyett, John D.

    1991-01-01

    A self-locking washer made of a flat elongated piece of material having a slot in one end of it. The washer is designed so that it can be placed underneath bolts or nuts which are already installed without completely removing the bolt or nut. A method of use of the self-locking washer is also disclosed.

  7. Modeling of bleach plant washer mineral scale

    Treesearch

    Alan Rudie; Peter Hart

    2004-01-01

    One of the more common areas of mineral scale formation in bleach plants is on washer face wires and the extraction rings of diffusion washers. Whereas most scale problems can be understood as a mixing of two streams that increase the concentrations of anions and cations and exceed a solubility product, washer problems are often more difficult to understand. The...

  8. Numerical simulation of seismic wave propagation from land-excited large volume air-gun source

    NASA Astrophysics Data System (ADS)

    Cao, W.; Zhang, W.

    2017-12-01

    The land-excited large volume air-gun source can be used to study regional underground structures and to detect temporal velocity changes. The air-gun source is characterized by rich low frequency energy (from bubble oscillation, 2-8Hz) and high repeatability. It can be excited in rivers, reservoirs or man-made pool. Numerical simulation of the seismic wave propagation from the air-gun source helps to understand the energy partitioning and characteristics of the waveform records at stations. However, the effective energy recorded at a distance station is from the process of bubble oscillation, which can not be approximated by a single point source. We propose a method to simulate the seismic wave propagation from the land-excited large volume air-gun source by finite difference method. The process can be divided into three parts: bubble oscillation and source coupling, solid-fluid coupling and the propagation in the solid medium. For the first part, the wavelet of the bubble oscillation can be simulated by bubble model. We use wave injection method combining the bubble wavelet with elastic wave equation to achieve the source coupling. Then, the solid-fluid boundary condition is implemented along the water bottom. And the last part is the seismic wave propagation in the solid medium, which can be readily implemented by the finite difference method. Our method can get accuracy waveform of land-excited large volume air-gun source. Based on the above forward modeling technology, we analysis the effect of the excited P wave and the energy of converted S wave due to different water shapes. We study two land-excited large volume air-gun fields, one is Binchuan in Yunnan, and the other is Hutubi in Xinjiang. The station in Binchuan, Yunnan is located in a large irregular reservoir, the waveform records have a clear S wave. Nevertheless, the station in Hutubi, Xinjiang is located in a small man-made pool, the waveform records have very weak S wave. Better understanding of

  9. Mounting improves heat-sink contact with beryllia washer

    NASA Technical Reports Server (NTRS)

    1966-01-01

    To conduct heat away from electrical components that must be electrically insulated from a metal heat sink, a metal washer and a coil spring are placed between one end of the electrical component and the beryllia washer mounted on the heat sink. The thermal paths are formed by the component lead and base, the metal and beryllia washers, and the compressed spring.

  10. Characteristic Analysis of Air-gun Source Wavelet based on the Vertical Cable Data

    NASA Astrophysics Data System (ADS)

    Xing, L.

    2016-12-01

    Air guns are important sources for marine seismic exploration. Far-field wavelets of air gun arrays, as a necessary parameter for pre-stack processing and source models, plays an important role during marine seismic data processing and interpretation. When an air gun fires, it generates a series of air bubbles. Similar to onshore seismic exploration, the water forms a plastic fluid near the bubble; the farther the air gun is located from the measurement, the more steady and more accurately represented the wavelet will be. In practice, hydrophones should be placed more than 100 m from the air gun; however, traditional seismic cables cannot meet this requirement. On the other hand, vertical cables provide a viable solution to this problem. This study uses a vertical cable to receive wavelets from 38 air guns and data are collected offshore Southeast Qiong, where the water depth is over 1000 m. In this study, the wavelets measured using this technique coincide very well with the simulated wavelets and can therefore represent the real shape of the wavelets. This experiment fills a technology gap in China.

  11. Carbon Nanotube Electron Gun

    NASA Technical Reports Server (NTRS)

    Ribaya, Bryan P. (Inventor); Nguyen, Cattien V. (Inventor)

    2013-01-01

    An electron gun, an electron source for an electron gun, an extractor for an electron gun, and a respective method for producing the electron gun, the electron source and the extractor are disclosed. Embodiments provide an electron source utilizing a carbon nanotube (CNT) bonded to a substrate for increased stability, reliability, and durability. An extractor with an aperture in a conductive material is used to extract electrons from the electron source, where the aperture may substantially align with the CNT of the electron source when the extractor and electron source are mated to form the electron gun. The electron source and extractor may have alignment features for aligning the electron source and the extractor, thereby bringing the aperture and CNT into substantial alignment when assembled. The alignment features may provide and maintain this alignment during operation to improve the field emission characteristics and overall system stability of the electron gun.

  12. Carbon nanotube electron gun

    NASA Technical Reports Server (NTRS)

    Nguyen, Cattien V. (Inventor); Ribaya, Bryan P. (Inventor)

    2010-01-01

    An electron gun, an electron source for an electron gun, an extractor for an electron gun, and a respective method for producing the electron gun, the electron source and the extractor are disclosed. Embodiments provide an electron source utilizing a carbon nanotube (CNT) bonded to a substrate for increased stability, reliability, and durability. An extractor with an aperture in a conductive material is used to extract electrons from the electron source, where the aperture may substantially align with the CNT of the electron source when the extractor and electron source are mated to form the electron gun. The electron source and extractor may have alignment features for aligning the electron source and the extractor, thereby bringing the aperture and CNT into substantial alignment when assembled. The alignment features may provide and maintain this alignment during operation to improve the field emission characteristics and overall system stability of the electron gun.

  13. 21 CFR 880.6800 - Washers for body waste receptacles.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Washers for body waste receptacles. 880.6800 Section 880.6800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Miscellaneous Devices § 880.6800 Washers for body waste receptacles. (a) Identification. A washer for body waste...

  14. 21 CFR 880.6800 - Washers for body waste receptacles.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Washers for body waste receptacles. 880.6800 Section 880.6800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Miscellaneous Devices § 880.6800 Washers for body waste receptacles. (a) Identification. A washer for body waste...

  15. 21 CFR 880.6800 - Washers for body waste receptacles.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Washers for body waste receptacles. 880.6800 Section 880.6800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Miscellaneous Devices § 880.6800 Washers for body waste receptacles. (a) Identification. A washer for body waste...

  16. 21 CFR 880.6800 - Washers for body waste receptacles.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Washers for body waste receptacles. 880.6800 Section 880.6800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Miscellaneous Devices § 880.6800 Washers for body waste receptacles. (a) Identification. A washer for body waste...

  17. 21 CFR 880.6800 - Washers for body waste receptacles.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Washers for body waste receptacles. 880.6800... Miscellaneous Devices § 880.6800 Washers for body waste receptacles. (a) Identification. A washer for body waste receptacles is a device intended for medical purposes that is used to clean and sanitize a body waste...

  18. Measured impacts of high efficiency domestic clothes washers in a community

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tomlinson, J.; Rizy, T.

    1998-07-01

    The US market for domestic clothes washers is currently dominated by conventional vertical-axis washers that typically require approximately 40 gallons of water for each wash load. Although the current market for high efficiency clothes washers that use much less water and energy is quite small, it is growing slowly as manufacturers make machines based on tumble action, horizontal-axis designs available and as information about the performance and benefits of such machines is developed and made available to consumers. To help build awareness of these benefits and to accelerate markets for high efficiency washers, the Department of Energy (DOE), under itsmore » ENERGY STAR{reg_sign} Program and in cooperation with a major manufacturers of high efficiency washers, conducted a field evaluation of high efficiency washers using Bern, Kansas as a test bed. Baseline washing machine performance data as well as consumer washing behavior were obtained from data collected on the existing machines of more than 100 participants in this instrumented study. Following a 2-month initial study period, all conventional machines were replaced by high efficiency, tumble-action washers, and the study continued for 3 months. Based on measured data from over 20,000 loads of laundry, the impact of the washer replacement on (1) individual customers` energy and water consumption, (2) customers` laundry habits and perceptions, and (3) the community`s water supply and waste water systems were determined. The study, its findings, and how information from the experiment was used to improve national awareness of high efficiency clothes washer benefits are described in this paper.« less

  19. 76 FR 72722 - Helical Spring Lock Washers From China and Taiwan

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-25

    ... Spring Lock Washers From China and Taiwan Determination On the basis of the record \\1\\ developed in the... antidumping duty orders on helical spring lock washers from China and Taiwan would be likely to lead to... with respect to helical spring lock washers from Taiwan. Background The Commission instituted these...

  20. RF Conditioning of the Photo-Cathode RF Gun at the Advanced Photon Source - NWA RF Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, T. L.; DiMonte, N.; Nassiri, A.

    A new S-band Photo-cathode (PC) gun was recently installed and RF conditioned at the Advanced Photon Source (APS) Injector Test-stand (ITS) at Argonne National Lab (ANL). The APS PC gun is a LCLS type gun fabricated at SLAC [1]. The PC gun was delivered to the APS in October 2013 and installed in the APS ITS in December 2013. At ANL, we developed a new method of fast detection and mitigation of the guns internal arcs during the RF conditioning process to protect the gun from arc damage and to RF condition more efficiently. Here, we report the results ofmore » RF measurements for the PC gun and an Auto-Restart method for high power RF conditioning.« less

  1. Preliminary engineering analysis for clothes washers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Biermayer, Peter J.

    1996-10-01

    The Engineering Analysis provides information on efficiencies, manufacturer costs, and other characteristics of the appliance class being analyzed. For clothes washers, there are two classes: standard and compact. Since data were not available to analyze the compact class, only clothes washers were analyzed in this report. For this analysis, individual design options were combined and ordered in a manner that resulted in the lowest cumulative cost/savings ratio. The cost/savings ratio is the increase in manufacturer cost for a design option divided by the reduction in operating costs due to fuel and water savings.

  2. 16 CFR Appendix F1 to Part 305 - Standard Clothes Washers

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 1 2014-01-01 2014-01-01 false Standard Clothes Washers F1 Appendix F1 to... LABELING RULEâ) Pt. 305, App. F1 Appendix F1 to Part 305—Standard Clothes Washers Range Information “Standard” includes all household clothes washers with a tub capacity of 1.6 cu. ft. or more. Capacity Range...

  3. 77 FR 13887 - Energy Conservation Program: Test Procedures for Residential Clothes Washers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-07

    ... Energy Conservation Program: Test Procedures for Residential Clothes Washers; Final Rule #0;#0;Federal... Conservation Program: Test Procedures for Residential Clothes Washers AGENCY: Office of Energy Efficiency and...) establishes new test procedures for residential clothes washers under the Energy Policy and Conservation Act...

  4. 35. VIEW OF DUAL VENTURI GAS WASHER IN THE GAS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    35. VIEW OF DUAL VENTURI GAS WASHER IN THE GAS WASHER PUMP HOUSE LOOKING NORTHEAST. - U.S. Steel Duquesne Works, Basic Oxygen Steelmaking Plant, Along Monongahela River, Duquesne, Allegheny County, PA

  5. 16 CFR Appendix F2 to Part 305 - Compact Clothes Washers

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 1 2014-01-01 2014-01-01 false Compact Clothes Washers F2 Appendix F2 to... LABELING RULEâ) Pt. 305, App. F2 Appendix F2 to Part 305—Compact Clothes Washers Range Information “Compact” includes all household clothes washers with a tub capacity of less than 1.6 cu. ft. Capacity Range of...

  6. Mechanical design and fabrication of the VHF-gun, the Berkeley normal-conducting continuous-wave high-brightness electron source

    NASA Astrophysics Data System (ADS)

    Wells, R. P.; Ghiorso, W.; Staples, J.; Huang, T. M.; Sannibale, F.; Kramasz, T. D.

    2016-02-01

    A high repetition rate, MHz-class, high-brightness electron source is a key element in future high-repetition-rate x-ray free electron laser-based light sources. The VHF-gun, a novel low frequency radio-frequency gun, is the Lawrence Berkeley National Laboratory (LBNL) response to that need. The gun design is based on a normal conducting, single cell cavity resonating at 186 MHz in the VHF band and capable of continuous wave operation while still delivering the high accelerating fields at the cathode required for the high brightness performance. The VHF-gun was fabricated and successfully commissioned in the framework of the Advanced Photo-injector EXperiment, an injector built at LBNL to demonstrate the capability of the gun to deliver the required beam quality. The basis for the selection of the VHF-gun technology, novel design features, and fabrication techniques are described.

  7. Mechanical design and fabrication of the VHF-gun, the Berkeley normal-conducting continuous-wave high-brightness electron source.

    PubMed

    Wells, R P; Ghiorso, W; Staples, J; Huang, T M; Sannibale, F; Kramasz, T D

    2016-02-01

    A high repetition rate, MHz-class, high-brightness electron source is a key element in future high-repetition-rate x-ray free electron laser-based light sources. The VHF-gun, a novel low frequency radio-frequency gun, is the Lawrence Berkeley National Laboratory (LBNL) response to that need. The gun design is based on a normal conducting, single cell cavity resonating at 186 MHz in the VHF band and capable of continuous wave operation while still delivering the high accelerating fields at the cathode required for the high brightness performance. The VHF-gun was fabricated and successfully commissioned in the framework of the Advanced Photo-injector EXperiment, an injector built at LBNL to demonstrate the capability of the gun to deliver the required beam quality. The basis for the selection of the VHF-gun technology, novel design features, and fabrication techniques are described.

  8. 10 CFR 431.152 - Definitions concerning commercial clothes washers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Definitions concerning commercial clothes washers. 431.152 Section 431.152 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Clothers Washers § 431.152 Definitions concerning commercial...

  9. Whose guns are stolen? The epidemiology of Gun theft victims.

    PubMed

    Hemenway, David; Azrael, Deborah; Miller, Matthew

    2017-12-01

    Gun theft is an important source of guns used by criminals. Yet no empirical work has focused on the characteristics of gun owners that distinguish those who have had their guns stolen from those who have not. In this study, we examine the demographics and behavioral characteristics of gun owners who report having had a gun stolen. Data come from a nationally representative probability-based online survey conducted in April 2015, with a linked follow-up survey in November 2015 that asked gun owners about any theft of their guns in the past 5 years. Of 1,604 gun-owning respondents, 2.4% (95% CI 1.6,3.6) reported that one or more guns had been stolen, with a mean number of guns stolen per theft of 1.5 (95% CI 1.0,2.0]. Risk factors for having a gun stolen were owning 6 or more guns, owning guns for protection, carrying a gun in the past month, storing guns unsafely, and living in the South region of the United States. The South accounts for 37% of US households, 43% of gun owners, and two-thirds of all gun thefts. We estimate that there are approximately 250,000 gun theft incidents per year, with about 380,000 guns stolen. We find that certain types of gun owners-who own many guns, who carry guns, and who do not store guns safely-are at higher risk to have their guns stolen. Tracing data show that states in the South are exporters of crime guns used in other states. Our survey results find that the majority of guns stolen in the US come from the South.

  10. Fabrication of compact electron gun for 6 MeV X-ray source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghodke, S.R.; Barnwal, Rajesh; Kumar, Mahendra, E-mail: ghodke_barc@yahoo.co.in

    The 6 MeV X-Ray source for container cargo scanning application has been designed and developed by the Accelerator and Pulse Power Division, BARC, Mumbai. This compact linac has been designed as a mobile system, to be mounted on a moving container. In linac-based cargo-scanning system, to work electron gun on a movable container, it has to be robust. Electron gun is to work at 10{sup -7} mbar vacuum and 2000 degree Celsius temperature. An effort is made to engineer the gun assembly to make it more robust and aligned. The linac acts as the source of X-rays, which fall onmore » the cargo and are then detected by the detector system. Many components are indigenously developed like grid, insulating ring, Tungsten filament and filament guide, which are made from alumina ceramic and Tantalum which is to work at 1500 degree Celsius. Filament connector is made from Invar to reduce heat loss and to make rigid connection. It was CNC machined and wire cut by EDM. Invar and Copper electrode feed through is shrink fitted with the help of liquid Nitrogen. Shrink fit tolerances of 15 micrometer are achieved by jig boring machining processes. Tantalum cup for LaB6 cathode and heat shield are made from die and punch mechanism. For alignment of electron emitter with beam axis this Tantalum cup is a crucial component. Electron gun is assembled and aligned its components with the help of precision jigs. The whole assembly was Helium leak tested by MSLD up to 4 x 10{sup -10} mbar.l/s vacuum, no leak was found. This paper will describe the machining, Tantalum cup forming, ceramic components development, heat shields, ceramic feed through etc of electron gun. (author)« less

  11. Advance in exploring the subsurface temporal evolution with Air-gun artificial source of Fujian, China

    NASA Astrophysics Data System (ADS)

    Yandan, H.; Jun, L.; Jin, X.; Tianyun, W.

    2017-12-01

    Geological disasters occur with the stress changes of subsurface medium. Since the stress changes slowly in the deep earth where only seismic wave can reach, monitoring the changes with repeatable seismic sources, ambient seismic noise and artificial sources has become a hot topic in seismology. The Fujian Earthquake Agency successfully constructed the Air-gun artificial source system and carried out over 6000 shots in six reservoirs. The correlation coefficient of signals can reach up to 0.99. Besides an excellent source, high recognition ability of seismic wave changes is required. It is common to use time delay estimation method based on cross-correlation to recognize the velocity changes. We investigate the accuracy of time delay detection of Air-gun source signals. Suppose that the medium does not change in a short time, we changed the explosion conditions of the air-gun array and recognized the subtle changes of signals by the time delay estimation method: (1) we changed the excitation depth from 8m to 30m, and found that the arriving time of bubble pulses advanced nearly 90ms. The results are quite consistent with the records of the OBS on the bottom of reservoir; (2) we changed the firing pressure from 800Psi to 2000Psi, and found that the bubble pulses were quite different but now we don't have any suitable numerical model to fit the changes; (3) we changed the excitation position of the air-gun, and divided the changed distance between the Air-gun and the near-shore seismograph by the corresponding changed travelling time. Then we got a velocity of 1.5km/s, which equals to the sound speed in water; (4) we controlled the microsecond of explosion moment from 0ms to 9ms, and counted the time delays of waveforms. Results are quite consistent with the theoretical value; (5) we changed the explosion mode, and quantitatively recognized the 0.1ms changes of the signal travel time. Our experiments show that the method is of high precision that can recognize the

  12. 77 FR 9700 - Large Residential Washers From Korea and Mexico

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-17

    ...)] Large Residential Washers From Korea and Mexico Determinations On the basis of the record \\1\\ developed... reasonable indication that an industry is materially injured by reason of imports from Mexico of large... imports of large residential washers from Mexico. Accordingly, effective December 30, 2011, the Commission...

  13. Note: Simulation and test of a strip source electron gun.

    PubMed

    Iqbal, Munawar; Islam, G U; Misbah, I; Iqbal, O; Zhou, Z

    2014-06-01

    We present simulation and test of an indirectly heated strip source electron beam gun assembly using Stanford Linear Accelerator Center (SLAC) electron beam trajectory program. The beam is now sharply focused with 3.04 mm diameter in the post anode region at 15.9 mm. The measured emission current and emission density were 1.12 A and 1.15 A/cm(2), respectively, that corresponds to power density of 11.5 kW/cm(2), at 10 kV acceleration potential. The simulated results were compared with then and now experiments and found in agreement. The gun is without any biasing, electrostatic and magnetic fields; hence simple and inexpensive. Moreover, it is now more powerful and is useful for accelerators technology due to high emission and low emittance parameters.

  14. 77 FR 51569 - Large Residential Washers From Korea and Mexico

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-24

    ...)] Large Residential Washers From Korea and Mexico Scheduling of the final phase of countervailing duty and... and Mexico of large residential washers, provided for in subheading 8450.20.00 of the Harmonized... and Mexico are being sold in the United States at less than fair value within the meaning of section...

  15. 76 FR 57075 - Helical Spring Lock Washers From China and Taiwan

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-15

    ... INTERNATIONAL TRADE COMMISSION [Investigation Nos. 731-TA-624-625; Third Review] Helical Spring... duty orders on helical spring lock washers from China and Taiwan. AGENCY: United States International...) to determine whether revocation of the antidumping duty orders on helical spring lock washers from...

  16. Note: Simulation and test of a strip source electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iqbal, Munawar, E-mail: muniqbal.chep@pu.edu.pk; Institute of High Energy Physics, Chinese Acedemy of Sciences, Beijing 100049; Islam, G. U.

    We present simulation and test of an indirectly heated strip source electron beam gun assembly using Stanford Linear Accelerator Center (SLAC) electron beam trajectory program. The beam is now sharply focused with 3.04 mm diameter in the post anode region at 15.9 mm. The measured emission current and emission density were 1.12 A and 1.15 A/cm{sup 2}, respectively, that corresponds to power density of 11.5 kW/cm{sup 2}, at 10 kV acceleration potential. The simulated results were compared with then and now experiments and found in agreement. The gun is without any biasing, electrostatic and magnetic fields; hence simple and inexpensive.more » Moreover, it is now more powerful and is useful for accelerators technology due to high emission and low emittance parameters.« less

  17. X-Band RF Gun Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vlieks, Arnold; Dolgashev, Valery; Tantawi, Sami

    In support of the MEGa-ray program at LLNL and the High Gradient research program at SLAC, a new X-band multi-cell RF gun is being developed. This gun, similar to earlier guns developed at SLAC for Compton X-ray source program, will be a standing wave structure made of 5.5 cells operating in the pi mode with copper cathode. This gun was designed following criteria used to build SLAC X-band high gradient accelerating structures. It is anticipated that this gun will operate with surface electric fields on the cathode of 200 MeV/m with low breakdown rate. RF will be coupled into themore » structure through a final cell with symmetric duel feeds and with a shape optimized to minimize quadrupole field components. In addition, geometry changes to the original gun, operated with Compton X-ray source, will include a wider RF mode separation, reduced surface electric and magnetic fields.« less

  18. Gun shows across a multistate American gun market: observational evidence of the effects of regulatory policies.

    PubMed

    Wintemute, Garen J

    2007-06-01

    To describe gun shows and assess the impact of increased regulation on characteristics linked to their importance as sources of guns used in crime. Cross-sectional, observational. Data were collected at a structured sample of 28 gun shows in California, which regulates these events and prohibits undocumented private party gun sales; and in Arizona, Nevada, Texas and Florida-all leading sources of California's crime guns--where these restrictions do not exist. Size of shows, measured by numbers of gun vendors and people in attendance; number and nature of guns for sale by gun vendors; measures of private party gun sales and illegal surrogate ("straw") gun purchases. Shows in comparison states were larger, but the number of attendees per gun vendor was higher in California. None of these differences was statistically significant. Armed attendees were more common in other states (median 5.7%, interquartile range (IQR) 3.9-10.0%) than in California (median 1.1%, IQR 0.5-2.2%), p = 0.0007. Thirty percent of gun vendors both in California and elsewhere were identifiable as licensed firearm retailers. There were few differences in the types or numbers of guns offered for sale; vendors elsewhere were more likely to sell assault weapons (34.9% and 13.3%, respectively; p = 0.001). Straw purchases were more common in the comparison states (rate ratio 6.6 (95% CI 0.9 to 49.1), p = 0.06). California's regulatory policies were associated with a decreased incidence of anonymous, undocumented gun sales and illegal straw purchases at gun shows. No significant adverse effects of these policies were observed.

  19. Energy-efficiency program for clothes washers, clothes dryers, and dishwashers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1977-11-01

    The objectives of this study of dishwashers, clothes washers, and clothes dryers are: to evaluate existing energy efficiency test procedures and recommend the use of specific test procedures for each appliance group and to establish the maximum economically and technologically feasible energy-efficiency improvement goals for each appliance group. Specifically, the program requirements were to determine the energy efficiency of the 1972 models, to evaluate the feasibility improvements that could be implemented by 1980 to maximize energy efficiency, and to calculate the percentage efficiency improvement based on the 1972 baseline and the recommended 1980 targets. The test program was conducted usingmore » 5 dishwashers, 4 top-loading clothes washers, one front-loading clothes washer, 4 electric clothes dryers, and 4 gas clothes dryers. (MCW)« less

  20. Legal status and source of offenders' firearms in states with the least stringent criteria for gun ownership.

    PubMed

    Vittes, Katherine A; Vernick, Jon S; Webster, Daniel W

    2013-02-01

    Gun possession by high-risk individuals presents a serious threat to public safety. U.S. federal law establishes minimum criteria for legal purchase and possession of firearms; many states have laws disqualifying additional categories for illegal possession. We used data from a national survey of state prison inmates to calculate: 1) the proportion of offenders, incarcerated for crimes committed with firearms in 13 states with the least restrictive firearm purchase and possession laws, who would have been prohibited if their states had stricter gun laws; and 2) the source of gun acquisition for offenders who were and were not legally permitted to purchase and possess firearms. Nearly three of ten gun offenders (73 of 253 or 28.9%) were legal gun possessors but would have been prohibited from purchasing or possessing firearms when committing their most recent offense if their states had stricter prohibitions. Offenders who were already prohibited under current law acquired their gun from a licensed dealer, where a background check is required, five times less often than offenders who were not prohibited (3.9% vs. 19.9%; χ(2)=13.31; p≤0.001). Nearly all (96.1%) offenders who were legally prohibited, acquired their gun from a supplier not required to conduct a background check. Stricter gun ownership laws would have made firearm possession illegal for many state prison inmates who used a gun to commit a crime. Requiring all gun sales to be subject to a background check would make it more difficult for these offenders to obtain guns.

  1. Determining the behavioural dose-response relationship of marine mammals to air gun noise and source proximity.

    PubMed

    Dunlop, Rebecca A; Noad, Michael J; McCauley, Robert D; Scott-Hayward, Lindsay; Kniest, Eric; Slade, Robert; Paton, David; Cato, Douglas H

    2017-08-15

    The effect of various anthropogenic sources of noise (e.g. sonar, seismic surveys) on the behaviour of marine mammals is sometimes quantified as a dose-response relationship, where the probability of an animal behaviourally 'responding' (e.g. avoiding the source) increases with 'dose' (or received level of noise). To do this, however, requires a definition of a 'significant' response (avoidance), which can be difficult to quantify. There is also the potential that the animal 'avoids' not only the source of noise but also the vessel operating the source, complicating the relationship. The proximity of the source is an important variable to consider in the response, yet difficult to account for given that received level and proximity are highly correlated. This study used the behavioural response of humpback whales to noise from two different air gun arrays (20 and 140 cubic inch air gun array) to determine whether a dose-response relationship existed. To do this, a measure of avoidance of the source was developed, and the magnitude (rather than probability) of this response was tested against dose. The proximity to the source, and the vessel itself, was included within the one-analysis model. Humpback whales were more likely to avoid the air gun arrays (but not the controls) within 3 km of the source at levels over 140 re. 1 µPa 2  s -1 , meaning that both the proximity and the received level were important factors and the relationship between dose (received level) and response is not a simple one. © 2017. Published by The Company of Biologists Ltd.

  2. Gun shows across a multistate American gun market: observational evidence of the effects of regulatory policies

    PubMed Central

    Wintemute, Garen J

    2007-01-01

    Objective To describe gun shows and assess the impact of increased regulation on characteristics linked to their importance as sources of guns used in crime. Design Cross‐sectional, observational. Subjects Data were collected at a structured sample of 28 gun shows in California, which regulates these events and prohibits undocumented private party gun sales; and in Arizona, Nevada, Texas and Florida—all leading sources of California's crime guns—where these restrictions do not exist. Main outcome measures Size of shows, measured by numbers of gun vendors and people in attendance; number and nature of guns for sale by gun vendors; measures of private party gun sales and illegal surrogate (“straw”) gun purchases. Results Shows in comparison states were larger, but the number of attendees per gun vendor was higher in California. None of these differences was statistically significant. Armed attendees were more common in other states (median 5.7%, interquartile range (IQR) 3.9–10.0%) than in California (median 1.1%, IQR 0.5–2.2%), p = 0.0007. Thirty percent of gun vendors both in California and elsewhere were identifiable as licensed firearm retailers. There were few differences in the types or numbers of guns offered for sale; vendors elsewhere were more likely to sell assault weapons (34.9% and 13.3%, respectively; p = 0.001). Straw purchases were more common in the comparison states (rate ratio 6.6 (95% CI 0.9 to 49.1), p = 0.06). Conclusions California's regulatory policies were associated with a decreased incidence of anonymous, undocumented gun sales and illegal straw purchases at gun shows. No significant adverse effects of these policies were observed. PMID:17567968

  3. 77 FR 24341 - Energy Conservation Program: Test Procedures for Residential Clothes Washers; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-24

    ... Program: Test Procedures for Residential Clothes Washers; Correction AGENCY: Office of Energy Efficiency... final rule establishing new and amended test procedures for residential clothes washers, published in... Energy (DOE) erroneously referenced the new test procedure, rather than the currently effective test...

  4. 21 CFR 884.1185 - Endometrial washer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Endometrial washer. 884.1185 Section 884.1185 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL...: Only to evaluate the endometrium, (ii) Contraindications: Pregnancy, history of uterine perforation, or...

  5. 21 CFR 884.1185 - Endometrial washer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Endometrial washer. 884.1185 Section 884.1185 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL...: Only to evaluate the endometrium, (ii) Contraindications: Pregnancy, history of uterine perforation, or...

  6. 21 CFR 884.1185 - Endometrial washer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Endometrial washer. 884.1185 Section 884.1185 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL...: Only to evaluate the endometrium, (ii) Contraindications: Pregnancy, history of uterine perforation, or...

  7. Gun Theft and Crime.

    PubMed

    Cook, Philip J

    2018-06-01

    Some law enforcement officials and other observers have asserted that theft is the primary source of guns to crime. In fact, the role of theft in supplying the guns used in robbery, assault, and murder is unknown, and current evidence provides little guidance about whether an effective program to reduce gun theft would reduce gun violence. The current article analyzes publicly available national data on gun theft together with a unique data set for Chicago. The results tend to support a conclusion that stolen guns play only a minor role in crime. First, publicly available data are used to calculate that thefts are only about 1% of all gun transactions nationwide. Second, an analysis of original data from Chicago demonstrates that less than 3% of crime guns recovered by the police have been reported stolen to the Chicago Police Department (CPD). If a gun is reported stolen, there is a 20% chance that it will be recovered, usually in conjunction with an arrest for illegal carrying. Less than half of those picked up with a stolen gun have a criminal record that includes violent offenses. Third, results from surveys of convicted criminals, both nationally and in Chicago, suggest that it is rare for respondents to have stolen the gun used in their most recent crime. The data on which these results are based have various shortcomings. A research agenda is proposed that would provide more certainty about the role of theft.

  8. 75 FR 29720 - Certain Helical Spring Lock Washers From the People's Republic of China: Final Results of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-27

    ...) provide a hardened bearing surface. The scope does not include internal or external tooth washers, nor... helical spring lock washers of carbon steel, of carbon alloy steel, or of stainless steel, heat- treated or non-heat-treated, plated or non-plated, with ends that are off-line. Helical spring lock washers...

  9. Gun ownership and social gun culture

    PubMed Central

    Kalesan, Bindu; Villarreal, Marcos D; Keyes, Katherine M; Galea, Sandro

    2016-01-01

    We assessed gun ownership rates in 2013 across the USA and the association between exposure to a social gun culture and gun ownership. We used data from a nationally representative sample of 4000 US adults, from 50 states and District of Columbia, aged >18 years to assess gun ownership and social gun culture performed in October 2013. State-level firearm policy information was obtained from the Brady Law Center and Injury Prevention and Control Center. One-third of Americans reported owning a gun, ranging from 5.2% in Delaware to 61.7% in Alaska. Gun ownership was 2.25-times greater among those reporting social gun culture (PR=2.25, 95% CI 2.02 to 2.52) than those who did not. In conclusion, we found strong association between social gun culture and gun ownership. Gun cultures may need to be considered for public health strategies that aim to change gun ownership in the USA. PMID:26124073

  10. Wisconsin SRF Electron Gun Commissioning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bisognano, Joseph J.; Bissen, M.; Bosch, R.

    The University of Wisconsin has completed fabrication and commissioning of a low frequency (199.6 MHz) superconducting electron gun based on a quarter wave resonator (QWR) cavity. Its concept was optimized to be the source for a CW free electron laser facility. The gun design includes active tuning and a high temperature superconducting solenoid. We will report on the status of the Wisconsin SRF electron gun program, including commissioning experience and first beam measurements.

  11. Can Standards Increase Consumer Welfare? Evidence from a Change in Clothes Washer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Xiaomei; Roberts, Michael J.; Yang, Hung-Chia

    We study prices and sales of individual clothes washer models before, during and after a 2007 standard that banned manufacture (but not sale) of low-e ciency units and increased the threshold for Energy Star certi cation. While quantities sold of washer models banned from manufacture decreased sharply, prices for banned models increased only modestly. At the same time, sales of higher-e ciency units rose markedly while prices for high-e ciency units declined. On average, washer e ciency increased but prices changed little. A simple welfare analysis indicates that consumer welfare loss from banned washers was far outweighed by gains frommore » lower-priced high-e ciency units. While a full cost-bene t analysis is not feasible with the available data, we estimate a lower-bound gain in consumer surplus equal to 6-16 percent of total sales. This result may accord with earlier theoretical research that shows quality standards can increase welfare in monopolistically competitive industries that possess increasing returns to scale (Ronnen, 1991). Thus, if energy e ciency is a close proxy for quality, energy e ciency standards may increase competition, market e ciency and welfare.« less

  12. Crime, Culture Conflict, and the Sources of Support for Gun Control.

    ERIC Educational Resources Information Center

    Kleck, Gary

    1996-01-01

    Questions whether attitudes towards gun control are influenced primarily by exposure to high crime rates, prior victimization, and fear of crime, or result from membership in social groups hostile to gun ownership. Maintains that support for gun control is more a product of culture conflict than a response to crime. (MJP)

  13. Where the guns come from: the gun industry and gun commerce.

    PubMed

    Wintemute, Garen J

    2002-01-01

    Under federal law, it is illegal for youth under age 18 to purchase rifles or shotguns, and for those under age 21 to purchase handguns. However, fatality and injury statistics clearly show that guns are finding their way into young people's hands. Many of these youth obtain guns through illegal gun markets. This article focuses on how guns in the United States are manufactured, marketed, and sold. The article shows how the legal and illegal gun markets are intimately connected and make guns easily accessible to youth. Although the domestic gun manufacturing industry is relatively small and has experienced declining sales in recent years, it has significant political clout and a large market for its products, and has engaged in aggressive marketing to youth. Lax oversight of licensed firearms dealers, combined with little or no regulation of private sales between gun owners, mean that guns can quickly moved from the legal gun market into the illegal market, where they can be acquired by young people. Certain guns, especially inexpensive, poorly made small handguns, are particularly attractive to criminals and youth. The author observes that several policy innovations--including increased regulation of licensed firearms dealers, intensified screening of prospective buyers, regulation of private sales, gun licensing and registration, and bans on some types of weapons--hold promise for decreasing the flow of guns into the hands of youth.

  14. Gun ownership and social gun culture.

    PubMed

    Kalesan, Bindu; Villarreal, Marcos D; Keyes, Katherine M; Galea, Sandro

    2016-06-01

    We assessed gun ownership rates in 2013 across the USA and the association between exposure to a social gun culture and gun ownership. We used data from a nationally representative sample of 4000 US adults, from 50 states and District of Columbia, aged >18 years to assess gun ownership and social gun culture performed in October 2013. State-level firearm policy information was obtained from the Brady Law Center and Injury Prevention and Control Center. One-third of Americans reported owning a gun, ranging from 5.2% in Delaware to 61.7% in Alaska. Gun ownership was 2.25-times greater among those reporting social gun culture (PR=2.25, 95% CI 2.02 to 2.52) than those who did not. In conclusion, we found strong association between social gun culture and gun ownership. Gun cultures may need to be considered for public health strategies that aim to change gun ownership in the USA. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  15. 76 FR 61343 - Certain Helical Spring Lock Washers From Taiwan and the People's Republic of China: Final Results...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-04

    ... bearing surface. The scope does not include internal or external tooth washers, nor does it include spring... are lock washers of carbon steel, of carbon alloy steel, or of stainless steel, heat-treated or non-heat-treated, plated or non-plated, with ends that are off-line. Lock washers are designed to: (1...

  16. Ion tracking in photocathode rf guns

    NASA Astrophysics Data System (ADS)

    Lewellen, John W.

    2002-02-01

    Projected next-generation linac-based light sources, such as PERL or the TESLA free-electron laser, generally assume, as essential components of their injector complexes, long-pulse photocathode rf electron guns. These guns, due to their design rf pulse durations of many milliseconds to continuous wave, may be more susceptible to ion bombardment damage of their cathodes than conventional rf guns, which typically use rf pulses of microsecond duration. This paper explores this possibility in terms of ion propagation within the gun, and presents a basis for future study of the subject.

  17. Identification of Noise Sources and Design of Noise Reduction Measures for a Pneumatic Nail Gun

    PubMed Central

    Jayakumar, Vignesh; Zechmann, Edward

    2015-01-01

    An experimental-analytical procedure was implemented to reduce the operating noise level of a nail gun, a commonly found power tool in a construction site. The procedure is comprised of preliminary measurements, identification and ranking of major noise sources and application of noise controls. Preliminary measurements show that the impact noise transmitted through the structure and the exhaust related noise were found to be the first and second major contributors. Applying a noise absorbing foam on the outside of the nail gun body was found to be an effective noise reduction technique. One and two-volume small mufflers were designed and applied to the exhaust side of the nail gun which reduced not only the exhaust noise but also the impact noise. It was shown that the overall noise level could be reduced by as much as 3.5 dB, suggesting that significant noise reduction is possible in construction power tools without any significant increase of the cost. PMID:26366038

  18. The high-efficiency laundry metering and marketing analysis (THELMA) project: Volume 2 -- Laboratory testing of clothes washers. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1997-10-01

    Horizontal axis (H-axis) clothes washers use less water and energy than conventional top-loading vertical axis (V-axis) clothes washers, yet sales in the US are insignificant. In the High Efficiency Laundry Metering and Market Analysis (THELMA) project, EPRI and a group of utilities have pooled their resources to develop the basis for successful DSM programs to accelerate the acceptance of this technology in the US market. This report covers the laboratory test phase of the THELMA project. The objective of this effort was to measure the performance of a representative sample of currently manufactured H-axis washers and to compare this performancemore » to that of a typical V-axis washer. Several aspects of performance were measured, with the emphasis on measures of energy consumption and water consumption: DOE washer capacity; hot and cold water consumption; energy consumption by the washer mechanical drive; DOE energy factor; water extraction effectiveness; effect of water extraction effectiveness on dryer energy; soil removal effectiveness; rinsing effectiveness; and gentleness of action. Eight H-axis washers, provided by US or European manufacturers, were tested. Test results varied over a range for these eight machines, but on average, the H-axis washers used 40% less energy (normalized to basket volume) and 25% less water (normalized to basket volume) when measured according to the DOE test procedure.« less

  19. Horizontal-axis clothes washer market poised for expansion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    George, K.L.

    1994-12-31

    The availability of energy- and water-efficient horizontal-axis washing machines in the North American market is growing, as US and European manufacturers position for an expected long-term market shift toward horizontal-axis (H-axis) technology. Four of the five major producers of washing machines in the US are developing or considering new H-axis models. New entrants, including US-based Staber Industries and several European manufacturers, are also expected to compete in this market. The intensified interest in H-axis technology is partly driven by speculation that new US energy efficiency standards, to be proposed in 1996 and implemented in 1999, will effectively mandate H-axis machines.more » H-axis washers typically use one-third to two-thirds less energy, water, and detergent than vertical-axis machines. Some models also reduce the energy needed to dry the laundry, since their higher spin speeds extract more water than is typical with vertical-axis designs. H-axis washing machines are the focus of two broadly-based efforts to support coordinated research and incentive programs by electric, gas, and water utilities: The High-Efficiency Laundry Metering/Marketing Analysis (THELMA), and the Consortium for Energy Efficiency (CEE) High-Efficiency Clothes Washer Initiative. These efforts may help to pave the way for new types of marketing partnerships among utilities and other parties that could help to speed adoption of H-axis washers.« less

  20. Theoretical investigation of the microwave electron gun

    NASA Astrophysics Data System (ADS)

    Gao, J.

    1990-12-01

    In this article the microwave electron gun (rf gun) is investigated theoretically in a general way. After a brief review of the sources of emittance growth in a cavity, the optimization criteria are given and optimized electric field distributions on the axes of the cavities are found, from which cavities for a rf gun can be designed.

  1. 10 CFR 429.20 - Residential clothes washers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...). For standard-size residential clothes washers, a water factor (WF) in gallons per cycle per cubic feet... integrated modified energy factor (IMEF) in cu ft/kWh/cycle, the integrated water factor (IWF) in gal/cycle... randomly selected and tested to ensure that— (i) Any represented value of the water factor, integrated...

  2. 10 CFR 429.20 - Residential clothes washers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...). For standard-size residential clothes washers, a water factor (WF) in gallons per cycle per cubic feet... integrated modified energy factor (IMEF) in cu ft/kWh/cycle, the integrated water factor (IWF) in gal/cycle... randomly selected and tested to ensure that— (i) Any represented value of the water factor, integrated...

  3. Seismic data collection from water gun and industrial background sources in the Chicago Sanitary and Ship Canal area, Illinois, 2011

    USGS Publications Warehouse

    Morrow, William S.; Carpenter, Phillip J.; Adams, Ryan F.

    2015-01-01

    The water gun is a tool adapted from deep marine geophysical surveys that is being evaluated for use as an acoustic fish deterrent to control the movement of invasive marine species. The water gun creates a seismic signal by using a compressed air discharge to move a piston rapidly within the water, resulting in an implosion. This energy pulse may be able to modify fish behavior or destroy marine life, such as the Asian carp, at some distance. The effects of this energy pulse on structures in the Chicago Sanitary and Ship Canal (CSSC), such as canal walls, shore lines, and lock structures, are not known. The potential effects of the use of a water gun on structures was identified as a concern in the CSSC and was assessed relative to existing background sources during this study. During September 2011, two water guns with piston sizes of 80 and 343 cubic inches, respectively, were tested in the CSSC at varying pressures and distances from a canal wall consisting of dolomite and dolomite setblock. Seismic data were collected during these water gun firings using geophones on land, in boreholes, and at the canal wall interface. Data were collected at varying depths in the canal water using hydrophones. Seismic data were also collected during the occurrences of barge traffic, railroad traffic located near the electric fish barrier in Lemont, and coal-loading operations at a coal power plant near the electric fish barrier. In general, energy produced by barge and railroad sources was less than energy created by the water gun. Energy levels produced by coal-loading operations at least 200 feet from geophones were approximately four times lower than energy levels measured during water gun operations.

  4. Counter-facing plasma guns for efficient extreme ultra-violet plasma light source

    NASA Astrophysics Data System (ADS)

    Kuroda, Yusuke; Yamamoto, Akiko; Kuwabara, Hajime; Nakajima, Mitsuo; Kawamura, Tohru; Horioka, Kazuhiko

    2013-11-01

    A plasma focus system composed of a pair of counter-facing coaxial guns was proposed as a long-pulse and/or repetitive high energy density plasma source. We applied Li as the source of plasma for improvement of the conversion efficiency, the spectral purity, and the repetition capability. For operation of the system with ideal counter-facing plasma focus mode, we changed the system from simple coaxial geometry to a multi-channel configuration. We applied a laser trigger to make synchronous multi-channel discharges with low jitter. The results indicated that the configuration is promising to make a high energy density plasma with high spectral efficiency.

  5. Simulation and optimization of a 10 A electron gun with electrostatic compression for the electron beam ion source.

    PubMed

    Pikin, A; Beebe, E N; Raparia, D

    2013-03-01

    Increasing the current density of the electron beam in the ion trap of the Electron Beam Ion Source (EBIS) in BNL's Relativistic Heavy Ion Collider facility would confer several essential benefits. They include increasing the ions' charge states, and therefore, the ions' energy out of the Booster for NASA applications, reducing the influx of residual ions in the ion trap, lowering the average power load on the electron collector, and possibly also reducing the emittance of the extracted ion beam. Here, we discuss our findings from a computer simulation of an electron gun with electrostatic compression for electron current up to 10 A that can deliver a high-current-density electron beam for EBIS. The magnetic field in the cathode-anode gap is formed with a magnetic shield surrounding the gun electrodes and the residual magnetic field on the cathode is (5 ÷ 6) Gs. It was demonstrated that for optimized gun geometry within the electron beam current range of (0.5 ÷ 10) A the amplitude of radial beam oscillations can be maintained close to 4% of the beam radius by adjusting the injection magnetic field generated by a separate magnetic coil. Simulating the performance of the gun by varying geometrical parameters indicated that the original gun model is close to optimum and the requirements to the precision of positioning the gun elements can be easily met with conventional technology.

  6. 10 CFR 429.20 - Residential clothes washers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... washers, a water factor (WF) in gallons per cycle per cubic feet (gal/cycle/cu ft). [76 FR 12451, Mar. 7... randomly selected and tested to ensure that— (i) Any represented value of the water factor, the estimated annual operating cost, the energy or water consumption, or other measure of energy or water consumption...

  7. Natural frequency identification of smart washer by using adaptive observer

    NASA Astrophysics Data System (ADS)

    Ito, Hitoshi; Okugawa, Masayuki

    2014-04-01

    Bolted joints are used in many machines/structures and some of them have been loosened during long time use, and unluckily these bolt loosening may cause a great accident of machines/structures system. These bolted joint, especially in important places, are main object of maintenance inspection. Maintenance inspection with human- involvement is desired to be improved owing to time-consuming, labor-intensive and high-cost. By remote and full automation monitoring of the bolt loosening, constantly monitoring of bolted joint is achieved. In order to detect loosening of bolted joints without human-involvement, applying a structural health monitoring technique and smart structures/materials concept is the key objective. In this study, a new method of bolt loosening detection by adopting a smart washer has been proposed, and the basic detection principle was discussed with numerical analysis about frequency equation of the system, was confirmed experimentally. The smart washer used in this study is in cantilever type with piezoelectric material, which adds the washer the self-sensing and actuation function. The principle used to detect the loosening of the bolts is a method of a bolt loosening detection noted that the natural frequency of a smart washer system is decreasing by the change of the bolt tightening axial tension. The feature of this proposed method is achieving to identify the natural frequency at current condition on demand by adopting the self-sensing and actuation function and system identification algorithm for varying the natural frequency depending the bolt tightening axial tension. A novel bolt loosening detection method by adopting adaptive observer is proposed in this paper. The numerical simulations are performed to verify the possibility of the adaptive observer-based loosening detection. Improvement of the detection accuracy for a bolt loosening is confirmed by adopting initial parameter and variable adaptive gain by numerical simulation.

  8. Gun Control, Gun Ownership, and Suicide Prevention.

    ERIC Educational Resources Information Center

    Lester, David

    1988-01-01

    Explored relationship between the extent of gun ownership and the strictness of gun control laws to suicide and homicide rates in the nine major geographic regions of the United States. Found gun ownership, rather than the strictness of gun control laws, was the strongest correlate of the rates of suicide and homicide by guns. (Author)

  9. Public Support for Gun Violence Prevention Policies Among Gun Owners and Non-Gun Owners in 2017.

    PubMed

    Barry, Colleen L; Webster, Daniel W; Stone, Elizabeth; Crifasi, Cassandra K; Vernick, Jon S; McGinty, Emma E

    2018-07-01

    To compare public support for 24 different gun policies between gun owners and non-gun owners in 2017. We fielded a national public opinion survey in January 2017 using an online panel to measure US adults' support for 24 gun policies. We compared support among gun owners and non-gun owners. For 23 of the 24 policies examined, most respondents supported restricting or regulating gun ownership. Only 8 of 24 policies had greater than a 10-point support gap between gun owners and non-gun owners. Policies with high public support and minimal support gaps by gun ownership status included universal background checks, greater accountability for licensed gun dealers unable to account for their inventory, higher safety training standards for concealed carry permit holders, improved reporting of records related to mental illness for background checks, gun prohibitions for persons subject to temporary domestic violence restraining orders, and gun violence restraining orders. Public Health Implications. Although there are important areas where Americans disagree on guns, large majorities of both gun owners and non-gun owners strongly support measures to strengthen US gun laws.

  10. A tapered multi-gap multi-aperture pseudospark-sourced electron gun based X-band slow wave oscillator

    NASA Astrophysics Data System (ADS)

    Kumar, N.; Lamba, R. P.; Hossain, A. M.; Pal, U. N.; Phelps, A. D. R.; Prakash, R.

    2017-11-01

    The experimental study of a tapered, multi-gap, multi-aperture pseudospark-sourced electron gun based X-band plasma assisted slow wave oscillator is presented. The designed electron gun is based on the pseudospark discharge concept and has been used to generate a high current density and high energy electron beam simultaneously. The distribution of apertures has been arranged such that the field penetration potency inside the backspace of the hollow-cathode is different while passing through the tapered gap region. This leads to non-concurrent ignition of the discharge through all the channels which is, in general, quite challenging in the case of multi-aperture plasma cathode electron gun geometries. Multiple and successive hollow cathode phases are reported from this electron gun geometry, which have been confirmed using simulations. This geometry also has led to the achievement of ˜71% fill factor inside the slow wave oscillator for an electron beam of energy of 20 keV and a beam current density in the range of 115-190 A/cm2 at a working argon gas pressure of 18 Pa. The oscillator has generated broadband microwave output in the frequency range of 10-11.7 GHz with a peak power of ˜10 kW for ˜50 ns.

  11. Ultra high vacuum test setup for electron gun

    NASA Astrophysics Data System (ADS)

    Pandiyar, M. L.; Prasad, M.; Jain, S. K.; Kumar, R.; Hannurkar, P. R.

    2008-05-01

    Ultra High Vacuum (UHV) test setup for electron gun testing has been developed. The development of next generation light sources and accelerators require development of klystron as a radio frequency power source, and in turn electron gun. This UHV electron gun test setup can be used to test the electron guns ranging from high average current, quasi-continuous wave to high peak current, single pulse etc. An electron gun has been designed, fabricated, assembled and tested for insulation up to 80 kV under the programme to develop high power klystron for future accelerators. Further testing includes the electron emission parameters characterization of the cathode, as it determines the development of a reliable and efficient electron gun with high electron emission current and high life time as well. This needs a clean ultra high vacuum to study these parameters particularly at high emission current. The cathode emission current, work function and vapour pressure of cathode surface material at high temperature studies will further help in design and development of high power electron gun The UHV electron gun test setup consists of Turbo Molecular Pump (TMP), Sputter Ion Pump (SIP), pressure gauge, high voltage and cathode power supplies, current measurement device, solenoid magnet and its power supply, residual gas analyser etc. The ultimate vacuum less than 2×10-9 mbar was achieved. This paper describes the UHV test setup for electron gun testing.

  12. The 3"/50 Gun. NAVPERS 10110.

    ERIC Educational Resources Information Center

    Bureau of Naval Personnel, Washington, DC.

    The document has been designed to provide enlisted men assigned to the 3"/50 gun with a self-study, on-the-job-training source for shipboard use. The material covered includes general description and operation, functions of various components, disassembly and reassembly, maintenance, and operational casualties of the 3"/50 gun. Detailed…

  13. Simulation and optimization of a 10 A electron gun with electrostatic compression for the electron beam ion source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pikin, A.; Beebe, E. N.; Raparia, D.

    Increasing the current density of the electron beam in the ion trap of the Electron Beam Ion Source (EBIS) in BNL's Relativistic Heavy Ion Collider facility would confer several essential benefits. They include increasing the ions' charge states, and therefore, the ions' energy out of the Booster for NASA applications, reducing the influx of residual ions in the ion trap, lowering the average power load on the electron collector, and possibly also reducing the emittance of the extracted ion beam. Here, we discuss our findings from a computer simulation of an electron gun with electrostatic compression for electron current upmore » to 10 A that can deliver a high-current-density electron beam for EBIS. The magnetic field in the cathode-anode gap is formed with a magnetic shield surrounding the gun electrodes and the residual magnetic field on the cathode is (5 Division-Sign 6) Gs. It was demonstrated that for optimized gun geometry within the electron beam current range of (0.5 Division-Sign 10) A the amplitude of radial beam oscillations can be maintained close to 4% of the beam radius by adjusting the injection magnetic field generated by a separate magnetic coil. Simulating the performance of the gun by varying geometrical parameters indicated that the original gun model is close to optimum and the requirements to the precision of positioning the gun elements can be easily met with conventional technology.« less

  14. Neuropsychological Functioning in Obsessive-Compulsive Washers: Drug-Naive Without Depressive Symptoms.

    PubMed

    Saremi, Ali Akbar; Shariat, Seyed Vahid; Nazari, Mohammad Ali; Dolatshahi, Behrooz

    2017-01-01

    Obsessive-Compulsive Disorder (OCD) is a complex and heterogeneous neuropsychiatric syndrome. Contamination obsessions and washing/cleaning compulsions are the most frequent clinical OCD subtypes. The current study aimed at examining the neuropsychological impairments in drug-naive obsessive-compulsive (OC) washers without depressive symptoms and their association with the severity of symptoms. In the current causal-comparative study, 35 patients with diagnostic and statistical mental disorders class (DSM)-IV diagnosed with washing-subtype OCD and 35 healthy subjects were selected by the convenience sampling method and evaluated by computerized neuropsychology battery and clinical tests as Stroop Color-Word Test (SCWT), Wisconsin Card Sorting Test (WCST), Go/No-Go Test, Digits Forward (DF), Digits Backward (DB), Yale-Brown Obsessive-Compulsive Scale (Y-BOCS), Beck Depression Inventory (BDI), Beck Anxiety Inventory (BAI), and General Health Questionnaire (GHQ)-28. The patients were matched to the comparison group with regard to age, gender, intelligence quotient (IQ), education, and handedness. All the tests were standardized in Iran. SPSS version 20.00 was used for descriptive and analytical data analysis. There was no statistically significant different between the OCD washing and the control groups regarding socio-demographic variables or IQ. There were significant differences between the OC washer and the healthy control groups on the neuropsychological functioning. The obtained results suggested that OC washers performed significantly worse on neuropsychological measures than the controls. There was no significant association between the severity of OC symptoms and the neuropsychological functions in the OCD washing group. It was concluded that executive function impairment, which is a core feature in OC washers was trait-like in nature.

  15. Neuropsychological Functioning in Obsessive-Compulsive Washers: Drug-Naive Without Depressive Symptoms

    PubMed Central

    Saremi, Ali Akbar; Shariat, Seyed Vahid; Nazari, Mohammad Ali; Dolatshahi, Behrooz

    2017-01-01

    Introduction: Obsessive–Compulsive Disorder (OCD) is a complex and heterogeneous neuropsychiatric syndrome. Contamination obsessions and washing/cleaning compulsions are the most frequent clinical OCD subtypes. The current study aimed at examining the neuropsychological impairments in drug-naive obsessive-compulsive (OC) washers without depressive symptoms and their association with the severity of symptoms. Methods: In the current causal-comparative study, 35 patients with diagnostic and statistical mental disorders class (DSM)-IV diagnosed with washing-subtype OCD and 35 healthy subjects were selected by the convenience sampling method and evaluated by computerized neuropsychology battery and clinical tests as Stroop Color-Word Test (SCWT), Wisconsin Card Sorting Test (WCST), Go/No-Go Test, Digits Forward (DF), Digits Backward (DB), Yale-Brown Obsessive–Compulsive Scale (Y-BOCS), Beck Depression Inventory (BDI), Beck Anxiety Inventory (BAI), and General Health Questionnaire (GHQ)-28. The patients were matched to the comparison group with regard to age, gender, intelligence quotient (IQ), education, and handedness. All the tests were standardized in Iran. SPSS version 20.00 was used for descriptive and analytical data analysis. Results: There was no statistically significant different between the OCD washing and the control groups regarding socio-demographic variables or IQ. There were significant differences between the OC washer and the healthy control groups on the neuropsychological functioning. The obtained results suggested that OC washers performed significantly worse on neuropsychological measures than the controls. There was no significant association between the severity of OC symptoms and the neuropsychological functions in the OCD washing group. Conclusion: It was concluded that executive function impairment, which is a core feature in OC washers was trait-like in nature. PMID:28781731

  16. 10 CFR 431.152 - Definitions concerning commercial clothes washers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... electrical, physical, and functional (or hydraulic) characteristics that affect energy consumption, energy... 10 Energy 3 2014-01-01 2014-01-01 false Definitions concerning commercial clothes washers. 431.152 Section 431.152 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN...

  17. 10 CFR 431.152 - Definitions concerning commercial clothes washers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... electrical, physical, and functional (or hydraulic) characteristics that affect energy consumption, energy... 10 Energy 3 2012-01-01 2012-01-01 false Definitions concerning commercial clothes washers. 431.152 Section 431.152 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN...

  18. 10 CFR 431.152 - Definitions concerning commercial clothes washers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... electrical, physical, and functional (or hydraulic) characteristics that affect energy consumption, energy... 10 Energy 3 2013-01-01 2013-01-01 false Definitions concerning commercial clothes washers. 431.152 Section 431.152 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN...

  19. Gun violence trends in movies.

    PubMed

    Bushman, Brad J; Jamieson, Patrick E; Weitz, Ilana; Romer, Daniel

    2013-12-01

    Many scientific studies have shown that the mere presence of guns can increase aggression, an effect dubbed the "weapons effect." The current research examines a potential source of the weapons effect: guns depicted in top-selling films. Trained coders identified the presence of violence in each 5-minute film segment for one-half of the top 30 films since 1950 and the presence of guns in violent segments since 1985, the first full year the PG-13 rating (age 13+) was used. PG-13-rated films are among the top-selling films and are especially attractive to youth. Results found that violence in films has more than doubled since 1950, and gun violence in PG-13-rated films has more than tripled since 1985. When the PG-13 rating was introduced, these films contained about as much gun violence as G (general audiences) and PG (parental guidance suggested for young children) films. Since 2009, PG-13-rated films have contained as much or more violence as R-rated films (age 17+) films. Even if youth do not use guns, these findings suggest that they are exposed to increasing gun violence in top-selling films. By including guns in violent scenes, film producers may be strengthening the weapons effect and providing youth with scripts for using guns. These findings are concerning because many scientific studies have shown that violent films can increase aggression. Violent films are also now easily accessible to youth (e.g., on the Internet and cable). This research suggests that the presence of weapons in films might amplify the effects of violent films on aggression.

  20. 23. VIEW OF 'PROCECO' WHEEL WASHER (uses spaulk and hot ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. VIEW OF 'PROCECO' WHEEL WASHER (uses spaulk and hot alkaline solution), Don N. Calabese, operator. - Juniata Shops, Erecting Shop & Machine Shop, East of Fourth Avenue, between Fourth & Fifth Streets, Altoona, Blair County, PA

  1. ELECTRON GUN

    DOEpatents

    Christofilos, N.C.; Ehlers, K.W.

    1960-04-01

    A pulsed electron gun capable of delivering pulses at voltages of the order of 1 mv and currents of the order of 100 amperes is described. The principal novelty resides in a transformer construction which is disposed in the same vacuum housing as the electron source and accelerating electrode structure of the gun to supply the accelerating potential thereto. The transformer is provided by a plurality of magnetic cores disposed in circumferentially spaced relation and having a plurality of primary windings each inductively coupled to a different one of the cores, and a helical secondary winding which is disposed coaxially of the cores and passes therethrough in circumferential succession. Additional novelty resides in the disposition of the electron source cathode filament input leads interiorly of the transformer secondary winding which is hollow, as well as in the employment of a half-wave filament supply which is synchronously operated with the transformer supply such that the transformer is pulsed during the zero current portions of the half-wave cycle.

  2. EH 11n modes E type in the disk and washer accelerating structure

    NASA Astrophysics Data System (ADS)

    Andreev, V. G.; Belugin, V. M.; Daikovsky, A. G.; Esin, S. K.; Kravchuk, L. V.; Paramonov, V. V.; Ryabov, A. D.

    1983-01-01

    The disk and washer accelerating structure has a great deal to do with high-beta structures progress. The frequencies and electromagnetic fields for modes, which have a different number of azimuthal variations, are calculated to determined the dispersion properties and other characteristics of parasitic modes in a disc and washer accelerating structure. The main attention was given to the accelerating structure of the linear accelerator of the Institute for Nuclear Research (INR) of the USSR Academy of Sciences. Modification of a structure for PIGMI accelerator (LANL, USA) is considered briefly.

  3. Gun Play

    ERIC Educational Resources Information Center

    Mechling, Jay

    2008-01-01

    Biology and the particular gun culture of the United States come together to explain the persistent and powerful attraction of American boys to both real guns and toy guns. The 1990s saw adults begin to conflate "the gun problem" with "the boy problem," sparking attempts (largely failed) to banish toy guns from homes and…

  4. State Firearm Laws and Interstate Transfer of Guns in the USA, 2006-2016.

    PubMed

    Collins, Tessa; Greenberg, Rachael; Siegel, Michael; Xuan, Ziming; Rothman, Emily F; Cronin, Shea W; Hemenway, David

    2018-06-01

    In a cross-sectional, panel study, we examined the relationship between state firearm laws and the extent of interstate transfer of guns, as measured by the percentage of crime guns recovered in a state and traced to an in-state source (as opposed to guns recovered in a state and traced to an out-of-state source). We used 2006-2016 data on state firearm laws obtained from a search of selected state statutes and 2006-2016 crime gun trace data from the Bureau of Alcohol, Tobacco, Firearms, and Explosives. We examined the relationship between state firearm laws and interstate transfer of guns using annual data from all 50 states during the period 2006-2016 and employing a two-way fixed effects model. The primary outcome variable was the percentage of crime guns recovered in a state that could be traced to an original point of purchase within that state as opposed to another state. The main exposure variables were eight specific state firearm laws pertaining to dealer licensing, sales restrictions, background checks, registration, prohibitors for firearm purchase, and straw purchase of guns. Four laws were independently associated with a significantly lower percentage of in-state guns: a waiting period for handgun purchase, permits required for firearm purchase, prohibition of firearm possession by people convicted of a violent misdemeanor, and a requirement for relinquishment of firearms when a person becomes disqualified from owning them. States with a higher number of gun laws had a lower percentage of traced guns to in-state dealers, with each increase of one in the total number of laws associated with a decrease of 1.6 percentage points in the proportion of recovered guns that were traced to an in-state as opposed to an out-of-state source. Based on an examination of the movement patterns of guns across states, the overall observed pattern of gun flow was out of states with weak gun laws and into states with strong gun laws. These findings indicate that certain

  5. An X-Band Gun Test Area at SLAC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Limborg-Deprey, C.; Adolphsen, C.; Chu, T.S.

    The X-Band Test Area (XTA) is being assembled in the NLCTA tunnel at SLAC to serve as a test facility for new RF guns. The first gun to be tested will be an upgraded version of the 5.6 cell, 200 MV/m peak field X-band gun designed at SLAC in 2003 for the Compton Scattering experiment run in ASTA. This new version includes some features implemented in 2006 on the LCLS gun such as racetrack couplers, increased mode separation and elliptical irises. These upgrades were developed in collaboration with LLNL since the same gun will be used in an injector formore » a LLNL Gamma-ray Source. Our beamline includes an X-band acceleration section which takes the electron beam up to 100 MeV and an electron beam measurement station. Other X-Band guns such as the UCLA Hybrid gun will be characterized at our facility.« less

  6. Low Emittance Guns for the ILC Polarized Electron Beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clendenin, J. E.; Brachmann, A.; Ioakeimidi, K.

    Polarized electron beams generated by DC guns are routinely available at several accelerators including JLAB, Mainz and SLAC. These guns operate with a cathode bias on the order of -100 kV. To minimize space charge effects, relatively long bunches are generated at the gun and then compressed longitudinally external to the gun just before and during initial acceleration. For linear colliders, this compression is accomplished using a combination of rf bunchers. For the basic design of the International Linear Collider (ILC), a 120 kV DC photocathode gun is used to produce a series of nanosecond bunches that are each compressedmore » by two sub-harmonic bunchers (SHBs) followed by an L-band buncher and capture section. The longitudinal bunching process results in a significantly higher emittance than produced by the gun alone. While high-energy experiments using polarized beams are not generally sensitive to the source emittance, there are several benefits to a lower source emittance including a simpler more efficient injector system and a lower radiation load during transport especially at bends as at the damping ring. For the ILC, the SHBs could be eliminated if the voltage of the gun is raised sufficiently. Simulations using the General Particle Tracer (GPT) package indicate that a cathode bias voltage of {>=}200 kV should allow both SHBs to be operated at 433 or even 650 MHz, while {>=}500 kV would be required to eliminate the SHBs altogether. Simulations can be used to determine the minimum emittance possible if the injector is designed for a given increased voltage. A possible alternative to the DC gun is an rf gun. Emittance compensation, routinely used with rf guns, is discussed for higher-voltage DC guns.« less

  7. Low Emittance Guns for the ILC Polarized Electron Beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clendenin, J.E.; Brachmann, A.; Ioakeimidi, K.

    Polarized electron beams generated by DC guns are routinely available at several accelerators including JLAB, Mainz and SLAC. These guns operate with a cathode bias on the order of -100 kV. To minimize space charge effects, relatively long bunches are generated at the gun and then compressed longitudinally external to the gun just before and during initial acceleration. For linear colliders, this compression is accomplished using a combination of rf bunchers. For the basic design of the International Linear Collider (ILC), a 120 kV DC photocathode gun is used to produce a series of nanosecond bunches that are each compressedmore » by two sub-harmonic bunchers (SHBs) followed by an L-band buncher and capture section. The longitudinal bunching process results in a significantly higher emittance than produced by the gun alone. While high-energy experiments using polarized beams are not generally sensitive to the source emittance, there are several benefits to a lower source emittance including a simpler more efficient injector system and a lower radiation load during transport especially at bends as at the damping ring. For the ILC, the SHBs could be eliminated if the voltage of the gun is raised sufficiently. Simulations using the General Particle Tracer (GPT) package indicate that a cathode bias voltage of {ge}200 kV should allow both SHBs to be operated at 433 or even 650 MHz, while {ge}500 kV would be required to eliminate the SHBs altogether. Simulations can be used to determine the minimum emittance possible if the injector is designed for a given increased voltage. A possible alternative to the DC gun is an rf gun. Emittance compensation, routinely used with rf guns, is discussed for higher-voltage DC guns.« less

  8. 76 FR 75873 - Certain Helical Spring Lock Washers From Taiwan and the People's Republic of China: Continuation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-05

    ... or bolts; and (3) provide a hardened bearing surface. The scope does not include internal or external tooth washers, nor does it include spring lock washers made of other metals, such as copper. Lock..., or of stainless steel, heat-treated or non-heat-treated, plated or non-plated, with ends that are off...

  9. 75 FR 9159 - Certain Helical Spring Lock Washers from the People's Republic of China: Extension of Time Limit...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-01

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-822] Certain Helical Spring Lock... of the administrative review of the antidumping duty order on certain helical spring lock washers... September 30, 2008. See Certain Helical Spring Lock Washers from the People's Republic of China: Preliminary...

  10. Gun Shows and Gun Violence: Fatally Flawed Study Yields Misleading Results

    PubMed Central

    Hemenway, David; Webster, Daniel; Pierce, Glenn; Braga, Anthony A.

    2010-01-01

    A widely publicized but unpublished study of the relationship between gun shows and gun violence is being cited in debates about the regulation of gun shows and gun commerce. We believe the study is fatally flawed. A working paper entitled “The Effect of Gun Shows on Gun-Related Deaths: Evidence from California and Texas” outlined this study, which found no association between gun shows and gun-related deaths. We believe the study reflects a limited understanding of gun shows and gun markets and is not statistically powered to detect even an implausibly large effect of gun shows on gun violence. In addition, the research contains serious ascertainment and classification errors, produces results that are sensitive to minor specification changes in key variables and in some cases have no face validity, and is contradicted by 1 of its own authors’ prior research. The study should not be used as evidence in formulating gun policy. PMID:20724672

  11. Gun shows and gun violence: fatally flawed study yields misleading results.

    PubMed

    Wintemute, Garen J; Hemenway, David; Webster, Daniel; Pierce, Glenn; Braga, Anthony A

    2010-10-01

    A widely publicized but unpublished study of the relationship between gun shows and gun violence is being cited in debates about the regulation of gun shows and gun commerce. We believe the study is fatally flawed. A working paper entitled "The Effect of Gun Shows on Gun-Related Deaths: Evidence from California and Texas" outlined this study, which found no association between gun shows and gun-related deaths. We believe the study reflects a limited understanding of gun shows and gun markets and is not statistically powered to detect even an implausibly large effect of gun shows on gun violence. In addition, the research contains serious ascertainment and classification errors, produces results that are sensitive to minor specification changes in key variables and in some cases have no face validity, and is contradicted by 1 of its own authors' prior research. The study should not be used as evidence in formulating gun policy.

  12. Encyclopedia of Gun Control and Gun Rights.

    ERIC Educational Resources Information Center

    Utter, Glenn H.

    This reference volume provides information on gun control and gun rights, including resources on the debate surrounding the Second Amendment and individuals and organizations focused on gun issues, along with statutes, court cases, events, and publications surrounding this current topic. Highlighted are the important organizations and their…

  13. State Gun Law Environment and Youth Gun Carrying in the United States.

    PubMed

    Xuan, Ziming; Hemenway, David

    2015-11-01

    Gun violence and injuries pose a substantial threat to children and youth in the United States. Existing evidence points to the need for interventions and policies for keeping guns out of the hands of children and youth. (1) To examine the association between state gun law environment and youth gun carrying in the United States, and (2) to determine whether adult gun ownership mediates this association. This was a repeated cross-sectional observational study design with 3 years of data on youth gun carrying from US states. The Youth Risk Behavior Survey comprises data of representative samples of students in grades 9 to 12 from biennial years of 2007, 2009, and 2011. We hypothesized that states with more restrictive gun laws have lower rates of youth gun carrying, and this association is mediated by adult gun ownership. State gun law environment as measured by state gun law score. Youth gun carrying was defined as having carried a gun on at least 1 day during the 30 days before the survey. In the fully adjusted model, a 10-point increase in the state gun law score, which represented a more restrictive gun law environment, was associated with a 9% decrease in the odds of youth gun carrying (adjusted odds ratio [AOR], 0.91 [95% CI, 0.86-0.96]). Adult gun ownership mediated the association between state gun law score and youth gun carrying (AOR, 0.94 [ 95% CI, 0.86-1.01], with 29% attenuation of the regression coefficient from -0.09 to -0.07 based on bootstrap resampling). More restrictive overall gun control policies are associated with a reduced likelihood of youth gun carrying. These findings are relevant to gun policy debates about the critical importance of strengthening overall gun law environment to prevent youth gun carrying.

  14. Clothes washer standards in China -- The problem of water andenergy trade-offs in establishing efficiency standards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Biermayer, Peter J.; Lin, Jiang

    2004-05-19

    Currently the sales of clothes washers in China consist ofseveral general varieties. Some use more energy (with or withoutincluding hot water energy use) and some use more water. Both energy andwater are in short supply in China. This poses the question - how do youtrade off water versus energy in establishing efficiency standards? Thispaper discusses how China dealt with this situation and how itestablished minimum efficiency standards for clothes washers.

  15. Gun threats against and self-defense gun use by California adolescents.

    PubMed

    Hemenway, David; Miller, Matthew

    2004-04-01

    To assess hostile gun use against and self-defense gun use by adolescents. We use random-digit-dial telephone survey data collected from approximately 5800 California adolescents, aged 12 through 17 years, between November 1, 2000, and October 31, 2001. The prevalence and correlates of reported hostile gun use against and self-defense gun use by adolescents, as well as qualitative information about these 2 types of gun uses. Correlates include age, sex, ethnicity, smoking, alcoholic binge drinking, threatening others, parents knowing their adolescent's whereabouts in the afternoon after school, attending school, area urbanization and poverty level, and living in a household with a gun. Approximately 4% of the adolescents reported ever having been threatened with a gun; only 0.3% reported using a gun in self-defense. Boys, smokers, adolescents who threatened others, and adolescents whose parents knew little about their whereabouts in the afternoon after school were more likely to report being threatened with a gun. Most episodes of self-defense gun use seem to be hostile interactions between adolescents with weapons. Far more California adolescents are threatened with a gun than use a gun in self-defense. Self-defense gun use is rare; many of the reported self-defense gun uses seem to be armed confrontations.

  16. 77. Detail view looking east showing Dovel horizontal gas washer ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    77. Detail view looking east showing Dovel horizontal gas washer in foreground, Rust Co. boilers and blowing engine house at left, and Babcock & Wilcox type boilers at right. - Sloss-Sheffield Steel & Iron, First Avenue North Viaduct at Thirty-second Street, Birmingham, Jefferson County, AL

  17. Trestle #1, detail of bolt and washer on wing wall ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Trestle #1, detail of bolt and washer on wing wall on north west side of northeast abutment. View to northeast - Promontory Route Railroad Trestles, S.P. Trestle 779.91, One mile southwest of junction of State Highway 83 and Blue Creek, Corinne, Box Elder County, UT

  18. Investigating the link between gun possession and gun assault.

    PubMed

    Branas, Charles C; Richmond, Therese S; Culhane, Dennis P; Ten Have, Thomas R; Wiebe, Douglas J

    2009-11-01

    We investigated the possible relationship between being shot in an assault and possession of a gun at the time. We enrolled 677 case participants that had been shot in an assault and 684 population-based control participants within Philadelphia, PA, from 2003 to 2006. We adjusted odds ratios for confounding variables. After adjustment, individuals in possession of a gun were 4.46 (P < .05) times more likely to be shot in an assault than those not in possession. Among gun assaults where the victim had at least some chance to resist, this adjusted odds ratio increased to 5.45 (P < .05). On average, guns did not protect those who possessed them from being shot in an assault. Although successful defensive gun uses occur each year, the probability of success may be low for civilian gun users in urban areas. Such users should reconsider their possession of guns or, at least, understand that regular possession necessitates careful safety countermeasures.

  19. Evaluation of a teflon based ultraviolet light system on the disinfection of water in a textile air washer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, J.E.; Whisnant, R.B.

    The report provides an in-depth evaluation of an ultraviolet (UV) disinfection unit as applied to the treatment of cooling water in a textile air washer system. The UV unit tests used a teflon tube to transport the aquatic phase. The unit reduced microbial populations and maintained an average level of 10,000 Colony formed unites/mL for the 6-month testing period, without the addition of biocides. No cleaning or other maintenance was required of the wetted surfaces during the testing period. Slime deposits observed on walls of the air washer during chemical treatment were also eliminated. The UV unit can be utilizedmore » on both cooling towers and air washers without extensive installation.« less

  20. rf traveling-wave electron gun for photoinjectors

    NASA Astrophysics Data System (ADS)

    Schaer, Mattia; Citterio, Alessandro; Craievich, Paolo; Reiche, Sven; Stingelin, Lukas; Zennaro, Riccardo

    2016-07-01

    The design of a photoinjector, in particular that of the electron source, is of central importance for free electron laser (FEL) machines where a high beam brightness is required. In comparison to standard designs, an rf traveling-wave photocathode gun can provide a more rigid beam with a higher brightness and a shorter pulse. This is illustrated by applying a specific optimization procedure to the SwissFEL photoinjector, for which a brightness improvement up to a factor 3 could be achieved together with a double gun output energy compared to the reference setup foreseeing a state-of-the-art S-band rf standing-wave gun. The higher brightness is mainly given by a (at least) double peak current at the exit of the gun which brings benefits for both the beam dynamics in the linac and the efficiency of the FEL process. The gun design foresees an innovative coaxial rf coupling at both ends of the structure which allows a solenoid with integrated bucking coil to be placed around the cathode in order to provide the necessary focusing right after emission.

  1. Gun Safety

    MedlinePlus

    Many U.S. households have guns, but they can cause harm if not handled properly. Here are some things you can do to keep yourself and ... safe: Teach children that they shouldn't touch guns and that if they see a gun, to ...

  2. Gun utopias? Firearm access and ownership in Israel and Switzerland

    PubMed Central

    Rosenbaum, Janet

    2011-01-01

    The 2011 attempted assassination of a US representative renewed the national gun control debate. Gun advocates claim that mass-casualty events are mitigated and deterred with three policies: (1) permissive gun laws, (2) widespread gun ownership, (3) encouragement of armed civilians who can intercept shooters, and cite Switzerland and Israel as exemplars. We evaluate these claims with analysis of International Crime Victimization Survey (ICVS) data and translation of laws and original source material. Swiss and Israeli laws limit firearm ownership and require permit renewal 14 times annually. ICVS analysis finds that the US has more firearms per capita and per household than either country. Switzerland and Israel curtail off-duty soldiers firearm access to prevent firearm deaths. Suicide among soldiers decreased by 40% after the Israeli armys 2006 reforms. Compared with the US, Switzerland and Israel have lower gun ownership and stricter gun laws, and their policies discourage personal gun ownership. PMID:22089893

  3. Gun utopias? Firearm access and ownership in Israel and Switzerland.

    PubMed

    Rosenbaum, Janet E

    2012-02-01

    The 2011 attempted assassination of a US representative renewed the national gun control debate. Gun advocates claim mass-casualty events are mitigated and deterred with three policies: (a) permissive gun laws, (b) widespread gun ownership, (c) and encouragement of armed civilians who can intercept shooters. They cite Switzerland and Israel as exemplars. We evaluate these claims with analysis of International Crime Victimization Survey (ICVS) data and translation of laws and original source material. Swiss and Israeli laws limit firearm ownership and require permit renewal one to four times annually. ICVS analysis finds the United States has more firearms per capita and per household than either country. Switzerland and Israel curtail off-duty soldiers' firearm access to prevent firearm deaths. Suicide among soldiers decreased by 40 per cent after the Israeli army's 2006 reforms. Compared with the United States, Switzerland and Israel have lower gun ownership and stricter gun laws, and their policies discourage personal gun ownership.

  4. Development of 50kV air-core transformer for electron gun static power source of 3MeV DC accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dewangan, S.; Bakhtsingh, R.I.; Rajan, R.N.

    A 3 MeV, 10 mA DC Electron Beam Accelerator based on the capacitively coupled parallel-fed voltage multiplier in 6 kg/cm{sup 2} SF{sub 6} gas environment is under commissioning at Electron Beam Centre, Kharghar, Navi Mumbai. Electron Gun is situated at -3 MV terminal which requires a constant power for its anode and filament. Gun power source has been derived by suitably coupling the ac components present in the HV Multiplier column. An aircore step down transformer rated for 50kV/600V/120kHz floating at 3 MV to extract the required power for electron gun from high voltage column has been developed. The transformermore » has been operated for 7 kW, 1 MeV of electron beam in 6 kg/cm{sup 2} nitrogen gas environment. The paper describes briefly about the design aspects and test results. (author)« less

  5. Strong gun laws are not enough: the need for improved enforcement of secondhand gun transfer laws in Massachusetts.

    PubMed

    Braga, Anthony A; Hureau, David M

    2015-10-01

    Research suggests that an overwhelming majority of crime guns were transferred by private sellers before recovery by law enforcement. Unfortunately, most states do not regulate these transactions. This study examines whether analyses of state-level private transfer data could be used to develop interventions to reduce the supply of handguns to violent criminals. Traced Boston crime handguns first sold at Massachusetts license dealers were matched to state secondhand gun transfer data. Logistic regression and descriptive statistics were used to analyze the characteristics of recovered crime guns and in-state primary and secondary market transaction patterns. For crime handguns with records of secondary market transactions in Massachusetts, many rapidly move from private transfer to recovery by the police. Unfortunately, important transaction data on the in-state sources of nearly 63% of recovered handguns were not readily available to law enforcement agencies. Data on private transfers of guns could be used to prevent violent injuries by reducing criminal access. However, the passage of strong private transfer gun laws needs to be accompanied by investments in the vigorous enforcement of reporting requirements. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. The Gun Dispute.

    ERIC Educational Resources Information Center

    Spitzer, Robert J.

    1999-01-01

    Explores the debate over gun ownership and gun control in the United States, focusing on the historic place of guns in U.S. society. The current national mood is more receptive than ever to restricting and regulating adolescent access to guns in light of recent school shootings. (SLD)

  7. Laser-free RF-gun as a combined source of THz and ps-sub-ps X-rays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agustsson, R.; Boucher, S.; Finn, O.

    A coherent, mm-sub-mm-wave source driven by a RF electron gun is proposed for wide research applications as well as auxiliary inspection and screening, safe imaging, cancer diagnostics, surface defectoscopy, and enhanced time-domain spectroscopy. It allows generation of high peak and average THz-sub-THz radiation power provided by beam pre-bunching and chirping in the RF gun followed by microbunching in magnetic compressor, and resonant Cherenkov radiation of an essentially flat beam in a robust, ~inch-long, planar, mm-sub-mm gap structure. The proof-of-principle has been successfully demonstrated in Phase I on a 5 MeV beam of L-band thermionic injector of Idaho Accelerator Center. Themore » system can also deliver an intense, ps-sub-ps bursts of low-to-moderate dose of relativistic electrons and X-ray radiation produced by the same beam required for pulsed radiolysis as well as to enhance screening efficiency, throughput and safety.« less

  8. Laser-free RF-gun as a combined source of THz and ps-sub-ps X-rays

    DOE PAGES

    Agustsson, R.; Boucher, S.; Finn, O.; ...

    2015-01-01

    A coherent, mm-sub-mm-wave source driven by a RF electron gun is proposed for wide research applications as well as auxiliary inspection and screening, safe imaging, cancer diagnostics, surface defectoscopy, and enhanced time-domain spectroscopy. It allows generation of high peak and average THz-sub-THz radiation power provided by beam pre-bunching and chirping in the RF gun followed by microbunching in magnetic compressor, and resonant Cherenkov radiation of an essentially flat beam in a robust, ~inch-long, planar, mm-sub-mm gap structure. The proof-of-principle has been successfully demonstrated in Phase I on a 5 MeV beam of L-band thermionic injector of Idaho Accelerator Center. Themore » system can also deliver an intense, ps-sub-ps bursts of low-to-moderate dose of relativistic electrons and X-ray radiation produced by the same beam required for pulsed radiolysis as well as to enhance screening efficiency, throughput and safety.« less

  9. Gun Safety (For Kids)

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español Gun Safety KidsHealth / For Kids / Gun Safety What's in ... from guns outside the home. If You Have Guns in Your Home If your parents keep guns ...

  10. Interior of southeast gun chamber (labeled "Gun Turret No. Two), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior of southeast gun chamber (labeled "Gun Turret No. Two), showing gun mounting pad, wall rings, small niche, and opening to outside - U.S. Naval Base, Pearl Harbor, Battery Adair, Princeton Place, Pearl City, Honolulu County, HI

  11. Energy consumption and usage characteristics from field measurements of residential dishwashers, clothes washers and clothes dryers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, Y.L.; Grot, R.A.

    1980-10-01

    The measured energy consumption and usage characteristics for household dishwashers, clothes washers, and clothes dryers for ten townhouses at Twin Rivers, N.J., are presented. Whenever the dishwashers and/or clothes washers were in use, the energy consumption, water consumption, frequency of usage, and water temperature were measured by a data acquisition system. The electrical energy of electric clothes dryers and the gas consumption of gas clothes dryers were measured, as well as their frequency and duration of use, and exhaust temperature. Typical household usage patterns of these major appliances are included.

  12. Note: Characteristic beam parameter for the line electron gun.

    PubMed

    Iqbal, M; Islam, G U; Zhou, Z; Chi, Y

    2013-11-01

    We have optimized the beam parameters of line source electron gun using Stanford Linear Accelerator Centre electron beam trajectory program (EGUN), utilizing electrostatic focusing only. We measured minimum beam diameter as 0.5 mm that corresponds to power density of 68.9 kW/cm(2) at 13.5 mm in the post-anode region which is more than two-fold (33 kW/cm(2)), of the previously reported results. The gun was operated for the validation of the theoretical results and found in good agreement. The gun is now without any magnetic and electrostatic focusing thus much simpler and more powerful.

  13. Note: Characteristic beam parameter for the line electron gun

    NASA Astrophysics Data System (ADS)

    Iqbal, M.; Islam, G. U.; Zhou, Z.; Chi, Y.

    2013-11-01

    We have optimized the beam parameters of line source electron gun using Stanford Linear Accelerator Centre electron beam trajectory program (EGUN), utilizing electrostatic focusing only. We measured minimum beam diameter as 0.5 mm that corresponds to power density of 68.9 kW/cm2 at 13.5 mm in the post-anode region which is more than two-fold (33 kW/cm2), of the previously reported results. The gun was operated for the validation of the theoretical results and found in good agreement. The gun is now without any magnetic and electrostatic focusing thus much simpler and more powerful.

  14. Temporal association between federal gun laws and the diversion of guns to criminals in Milwaukee.

    PubMed

    Webster, Daniel W; Vernick, Jon S; Bulzacchelli, Maria T; Vittes, Katherine A

    2012-02-01

    The practices of licensed gun dealers can threaten the safety of urban residents by facilitating the diversion of guns to criminals. In 2003, changes to federal law shielded gun dealers from the release of gun trace data and provided other protections to gun dealers. The 14-month period during which the dealer did not sell junk guns was associated with a 68% reduction in the diversion of guns to criminals within a year of sale by the dealer and a 43% increase in guns diverted to criminals following sales by other dealers. The laws were associated with a 203% increase in the number of guns diverted to criminals within a year of sale by the gun store, which was the focus of this study. Policies which affect gun dealer accountability appeared to influence the diversion of guns to criminals.

  15. Bacteria-free water for automatic washer-disinfectors: an impossible dream?

    PubMed

    Cooke, R P; Whymant-Morris, A; Umasankar, R S; Goddard, S V

    1998-05-01

    The ability of a new automatic washer-disinfector system (AWDS), fitted with a water filtration system to provide bacteria-free water and so avoid the risk of mycobacterial contamination of fibreoptic bronchoscopes, was examined. Four new Astec 'MP' Safescope washer-disinfectors, with coarse and fine (0.2 micron) filters attached close to the outlet taps, were supplied with non-softened mains water. Water samples from the tank supply and outlet taps were regularly assessed for bacterial quality over a six-month period. Outlet samples were also analysed after fine filter change and purgation with peracetic acid. All bronchoalveolar lavage specimens (BALS) were stained and cultured for mycobacteria. Only 13 out of 53 outlet samples (24%) were culture-negative. There was no improvement after filter change. Residual anti-bacterial effect of peracetic acid lasted up to 48 h following AWDS purgation. No tank samples were bacteria-free. Sixty BALS were processed, two samples were culture-positive and grew M. tuberculosis and one was also smear-positive. Though mycobacterial contamination of bronchoscopes was not evident, the water filtration system was unable to reliably provide sterile rinse water.

  16. Effects of Exposure to Gun Violence in Movies on Children's Interest in Real Guns.

    PubMed

    Dillon, Kelly P; Bushman, Brad J

    2017-11-01

    More US children die by accidental gun use than children in other developed countries. One factor that can influence children's interest in guns is exposure to media containing guns. To test whether children who see a movie containing guns will handle a real gun longer and will pull the trigger more times than children who see the same movie not containing guns. One hundred four children aged 8 to 12 years recruited through advertisements were randomly assigned in pairs to watch a 20-minute PG-rated movie containing or not containing guns in a university laboratory. Children then played with toys and games in a room for 20 minutes while being video recorded. A cabinet in the room contained a real (disabled) gun with a sensor counting trigger pulls. Recordings were coded for the time spent holding the gun and in aggressive play. Data were collected from July 15, 2015, through January 1, 2016, and analyzed using generalized estimating equations (Tweedie log-link for time spent holding the gun; Poisson log-link for pulling the trigger). The 2 main outcomes were time spent holding the gun and the number of trigger pulls. Control variables included sex, age, trait aggressiveness, exposure to violent media, interest in guns, and number of guns at home. Among the 104 study participants (62 boys [59.6%] and 42 girls [40.4%]; mean (SD) age, 9.9 [1.5] years), the adjusted median number of trigger pulls among children who saw the movie containing guns was 2.8 (interquartile range [IQR], 0.2-2.8) compared with 0.01 (IQR, 0.01-0.2) among children who saw the movie not containing guns (adjusted odds ratio, 22.3; 95% CI, 6.0-83.4; P < .001). The adjusted median number of seconds spent holding the gun among children who saw a movie containing guns was 53.1 (IQR, 35.5-53.1) compared with 11.1 (IQR, 10.7-16.7) among children who saw the movie not containing guns (adjusted odds ratio, 3.0; 95% CI, 0.9-9.9; P = .07). Qualitative analyses on 4 pairs from each condition found

  17. Subcaliber Guns

    DTIC Science & Technology

    1988-06-16

    310-6 11. TITLE (Include Security Classification) "SUBCALIBER GUNS " 12. PERSONAL AUTHOR(S) 13a. TYPE OF REPORT 13b. TIME COVERED 14. DATE OF REPORT...necessary and identify by block number) FIELD GROUP SUB-GROUP 4Large caliber weapons, .,Subcaliber guns (" J-) Parent weapons.; Small caliber weapons’y...19, ABSTRACT (Continue on reverse if necessary and identify by block number) Provides procedures for determining the suitability of subcaliber guns

  18. Survey of SRF guns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belomestnykh, S.

    Developing Superconducting RF (SRF) electron guns is an active field with several laboratories working on different gun designs. While the first guns were based on elliptic cavity geometries, Quarter Wave Resonator (QWR) option is gaining popularity. QWRs are especially well suited for producing beams with high charge per bunch. In this talk we will describe recent progress in developing both types of SRF guns. SRF guns made excellent progress in the last two years. Several guns generated beams and one, at HZDR, injected beam into an accelerator. By accomplishing this, HZDR/ELBE gun demonstrated feasibility of the SRF gun concept withmore » a normal-conducting Cs{sub 2}Te cathode. The cathode demonstrated very good performance with the lifetime of {approx}1 year. However, for high average current/high bunch charge operation CsK{sub 2}Sb is preferred as it needs green lasers, unlike UV laser for the Cs{sub 2}Te, which makes it easier to build laser/optics systems. Other high QE photocathodes are being developed for SRF guns, most notably diamond-amplified photocathode. Several QWR guns are under development with one producing beam already. They are very promising for high bunch charge operation. The field is very active and we should expect more good results soon.« less

  19. Electrostatic focusing of directly heated linear filament gun using EGUN

    NASA Astrophysics Data System (ADS)

    Iqbal, Munawar; Lodhi, M. A. K.; Majeed, Zahid; Batani, Dimitri

    2011-06-01

    This paper presents the optimization of a line source rectangular electron gun using electrostatic focusing. We optimized the gun by shaping the configuration of its electrodes in order to achieve the desired focusing characteristics, namely maximum focusing distance and minimum beam spread. The optimization has been carried out using the software EGUN. We have also simplified the gun design using only one focusing electrode at the same potential as that of the cathode and by avoiding magnetic focusing field, separate focusing electrodes and additional power supply, thus minimizing the cost without any loss in its accuracy and efficient performance. This gun with the optimum configuration was used in actual experiment and the results of the simulation were compared with the experimental measurements.

  20. Note: Characteristic beam parameter for the line electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iqbal, M.; Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049; Islam, G. U.

    We have optimized the beam parameters of line source electron gun using Stanford Linear Accelerator Centre electron beam trajectory program (EGUN), utilizing electrostatic focusing only. We measured minimum beam diameter as 0.5 mm that corresponds to power density of 68.9 kW/cm{sup 2} at 13.5 mm in the post-anode region which is more than two-fold (33 kW/cm{sup 2}), of the previously reported results. The gun was operated for the validation of the theoretical results and found in good agreement. The gun is now without any magnetic and electrostatic focusing thus much simpler and more powerful.

  1. Guns and Violence. Current Controversies.

    ERIC Educational Resources Information Center

    Kim, Henny H., Ed.

    This book focuses on gun violence and gun control, presenting both sides of arguments about firearms ownership and gun control. Each of five chapters poses a question about gun control and provides answers for both sides of the question. The following essays are included: (1) "Gun Violence Is Becoming an Epidemic" (Bob Herbert); (2) "Gun Violence…

  2. The self adapting washer for lag screw fixation of mandibular fractures: finite element analysis and preclinical evaluation.

    PubMed

    Terheyden, H; Mühlendyck, C; Feldmann, H; Ludwig, K; Härle, F

    1999-02-01

    Besides rigid fixation, lag screws have distinct advantages compared with plates in appropriate indications in mandibular fractures. However, in current lag screw systems, the relatively small area of the screw head has to transfer the tensile force which can exceed 1000 N in the symphysis, to the thin cortical bone plate. Countersinking, which is obligatory in most systems, will weaken the cortical plate. Finite element analysis (FEA) revealed that load in this situation can exceed the normal tensile strength of metal and bone. Consequently, a new washer was constructed which both increased the supporting surface and did not require countersinking. The washer is self adapting (SAW) to the cortical plate in a defined position, forming a ball and socket joint with the screw head. Using the FEA model, a ten-fold reduction in load on bone and metal was observed with the new washer. In a miniature pig mandibular symphysis fracture model, the clinical applicability and a favourable histological reaction were demonstrated, compared with conventional lag screw designs.

  3. Reduction of Gun Erosion and Correlation of Gun Erosion Measurements

    NASA Technical Reports Server (NTRS)

    Bogdanoff, Dave; Wercinski, Paul (Technical Monitor)

    1997-01-01

    Gun barrel erosion is serious problem with two-stage light gas guns. Excessive barrel erosion can lead to poor or failed launches and frequent barrel changes, with the corresponding down time. Also, excessive barrel erosion can limit the maximum velocity obtainable by loading down the hydrogen working gas with eroded barrel material. Guided by a CFD code, the operating conditions of the Ames 0.5-inch gun were modified to reduce barrel erosion. The changes implemented included: (1) reduction in the piston mass, powder mass and hydrogen fill pressure; and (2) reduction in pump tube volume, while maintaining hydrogen mass. The latter change was found, in particular, to greatly reduce barrel erosion. For muzzle velocity ranges of 6.1 - 6.9 km/sec, the barrel erosion was reduced by a factor of 10. Even for the higher muzzle velocity range of 7.0 - 8.2 km/sec, the barrel erosion was reduced by a factor of 4. Gun erosion data from the Ames 0.5-inch, 1.0-inch, and 1.5-inch guns operated over a wide variety of launch conditions was examined and it was found that this data could be correlated using four different parameters: normalized powder charge energy, normalized hydrogen energy density, normalized pump tube volume and barrel diameter. The development of the correlation and the steps used to collapse the experimental data are presented. Over a certain parameter range in the correlation developed, the barrel erosion per shot is found to increase very rapidly. The correlation should prove useful in the selection of gun operating conditions and the design of new guns. Representative shapes of eroded gun barrels are also presented.

  4. 77 FR 20291 - Energy Conservation Program: Test Procedures for Residential Clothes Washers; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-04

    ... Conservation Program: Test Procedures for Residential Clothes Washers; Correction AGENCY: Office of Energy.... Department of Energy (DOE) is correcting a final rule establishing revised test procedures for residential... factor calculation section of the currently applicable test procedure. DATES: Effective: April 6, 2012...

  5. Gun Sales. Firearm Facts.

    ERIC Educational Resources Information Center

    Duker, Laurie, Ed.

    Minimal federal regulations on firearm sales have facilitated the proliferation of guns, gun owners, and gun dealers in the United States. This fact sheet offers data on the growing number of firearm dealers, the relative ease of obtaining and keeping a license to sell guns from the Federal Bureau of Alcohol, Tobacco, and Firearms, the lack of…

  6. Current transmission and nonlinear effects in un-gated thermionic cathode RF guns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edelen, J. P.; Harris, J. R.

    Un-gated thermionic cathode RF guns are well known as a robust source of electrons for many accelerator applications. These sources are in principle scalable to high currents without degradation of the transverse emittance due to control grids but they are also known for being limited by back-bombardment. While back-bombardment presents a significant limitation, there is still a lack of general understanding on how emission over the whole RF period will affect the nature of the beams produced from these guns. In order to improve our understanding of how these guns can be used in general we develop analytical models thatmore » predict the transmission efficiency as a function of the design parameters, study how bunch compression and emission enhancement caused by Schottky barrier lowering affect the output current profile in the gun, and study the onset of space-charge limited effects and the resultant virtual cathode formation leading to a modulation in the output current distribution.« less

  7. Testing a GaAs cathode in SRF gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, E.; Kewisch, J.; Ben-Zvi, I.

    RF electron guns with a strained superlattice GaAs cathode are expected to generate polarized electron beams of higher brightness and lower emittance than do DC guns, due to their higher field gradient at the cathode's surface and lower cathode temperature. We plan to install a bulk GaAs:Cs in a SRF gun to evaluate the performance of both the gun and the cathode in this environment. The status of this project is: In our 1.3 GHz 1/2 cell SRF gun, the vacuum can be maintained at nearly 10{sup -12} Torr because of cryo-pumping at 2K. With conventional activation of bulk GaAs,more » we obtained a QE of 10% at 532 nm, with lifetime of more than 3 days in the preparation chamber and have shown that it can survive in transport from the preparation chamber to the gun. The beam line has been assembled and we are exploring the best conditions for baking the cathode under vacuum. We report here the progress of our test of the GaAs cathode in the SRF gun. Future particle accelerators, such as eRHIC and the ILC require high-brightness, high-current polarized electrons. Strained superlattice GaAs:Cs has been shown to be an efficient cathode for producing polarized electrons. Activation of GaAs with Cs,O(F) lowers the electron affinity and makes it energetically possible for all the electrons, excited into the conduction band that drift or diffuse to the emission surface, to escape into the vacuum. Presently, all operating polarized electron sources, such as the CEBAF, are DC guns. In these devices, the excellent ultra-high vacuum extends the lifetime of the cathode. However, the low field gradient on the photocathode's emission surface of the DC guns limits the beam quality. The higher accelerating gradients, possible in the RF guns, generate a far better beam. Until recently, most RF guns operated at room temperature, limiting the vacuum to {approx}10{sup -9} Torr. This destroys the GaAs's NEA surface. The SRF guns combine the excellent vacuum conditions of DC guns and the

  8. Racism, gun ownership and gun control: biased attitudes in US whites may influence policy decisions.

    PubMed

    O'Brien, Kerry; Forrest, Walter; Lynott, Dermot; Daly, Michael

    2013-01-01

    Racism is related to policies preferences and behaviors that adversely affect blacks and appear related to a fear of blacks (e.g., increased policing, death penalty). This study examined whether racism is also related to gun ownership and opposition to gun controls in US whites. The most recent data from the American National Election Study, a large representative US sample, was used to test relationships between racism, gun ownership, and opposition to gun control in US whites. Explanatory variables known to be related to gun ownership and gun control opposition (i.e., age, gender, education, income, conservatism, anti-government sentiment, southern vs. other states, political identification) were entered in logistic regression models, along with measures of racism, and the stereotype of blacks as violent. Outcome variables included; having a gun in the home, opposition to bans on handguns in the home, support for permits to carry concealed handguns. After accounting for all explanatory variables, logistic regressions found that for each 1 point increase in symbolic racism there was a 50% increase in the odds of having a gun at home. After also accounting for having a gun in the home, there was still a 28% increase in support for permits to carry concealed handguns, for each one point increase in symbolic racism. The relationship between symbolic racism and opposition to banning handguns in the home (OR1.27 CI 1.03,1.58) was reduced to non-significant after accounting for having a gun in the home (OR1.17 CI.94,1.46), which likely represents self-interest in retaining property (guns). Symbolic racism was related to having a gun in the home and opposition to gun control policies in US whites. The findings help explain US whites' paradoxical attitudes towards gun ownership and gun control. Such attitudes may adversely influence US gun control policy debates and decisions.

  9. Women and Guns. Firearm Facts.

    ERIC Educational Resources Information Center

    Duker, Laurie, Ed.

    Many gun manufacturers market guns to women claiming a gun can provide protection. Statistics provided in this fact sheet indicate gun ownership may provide a false sense of security that can be fatal, since the greatest threat to a woman comes from the people and guns within her own home. Contrary to "typical" scenarios created by advertisers,…

  10. 77 FR 59719 - Energy Conservation Program: Energy Conservation Standards for Residential Clothes Washers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-01

    ... DEPARTMENT OF ENERGY 10 CFR Parts 429 and 430 [Docket Number EERE-2008-BT-STD-0019] RIN 1904-AB90 Energy Conservation Program: Energy Conservation Standards for Residential Clothes Washers AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION: Notice of effective date and...

  11. Racism, Gun Ownership and Gun Control: Biased Attitudes in US Whites May Influence Policy Decisions

    PubMed Central

    O’Brien, Kerry; Forrest, Walter; Lynott, Dermot; Daly, Michael

    2013-01-01

    Objective Racism is related to policies preferences and behaviors that adversely affect blacks and appear related to a fear of blacks (e.g., increased policing, death penalty). This study examined whether racism is also related to gun ownership and opposition to gun controls in US whites. Method The most recent data from the American National Election Study, a large representative US sample, was used to test relationships between racism, gun ownership, and opposition to gun control in US whites. Explanatory variables known to be related to gun ownership and gun control opposition (i.e., age, gender, education, income, conservatism, anti-government sentiment, southern vs. other states, political identification) were entered in logistic regression models, along with measures of racism, and the stereotype of blacks as violent. Outcome variables included; having a gun in the home, opposition to bans on handguns in the home, support for permits to carry concealed handguns. Results After accounting for all explanatory variables, logistic regressions found that for each 1 point increase in symbolic racism there was a 50% increase in the odds of having a gun at home. After also accounting for having a gun in the home, there was still a 28% increase in support for permits to carry concealed handguns, for each one point increase in symbolic racism. The relationship between symbolic racism and opposition to banning handguns in the home (OR1.27 CI 1.03,1.58) was reduced to non-significant after accounting for having a gun in the home (OR1.17 CI.94,1.46), which likely represents self-interest in retaining property (guns). Conclusions Symbolic racism was related to having a gun in the home and opposition to gun control policies in US whites. The findings help explain US whites’ paradoxical attitudes towards gun ownership and gun control. Such attitudes may adversely influence US gun control policy debates and decisions. PMID:24204867

  12. Effects of a Gun Dealer's Change in Sales Practices on the Supply of Guns to Criminals

    PubMed Central

    Vernick, Jon S.; Bulzacchelli, Maria T.

    2006-01-01

    Licensed gun dealers are a major conduit for gun trafficking. Prior to May 1999, a single gun store sold more than half of the guns recovered from criminals in Milwaukee, WI, shortly following retail sale. On May 10, 1999, the store stopped selling small, inexpensive handguns popular with criminals, often called “Saturday night specials.” The purpose of this study was to estimate the effect of this gun store's changed sales practices on criminals' acquisition of new guns. We used an interrupted time-series design with comparisons to test for changes in the number of guns that police recovered from criminals within a year of retail sale following the gun dealer's new sales policy. The dealer's changed sales policy was associated with a 96% decrease in recently sold, small, inexpensive handguns use in crime in Milwaukee, a 73% decrease in crime guns recently sold by this dealer, and a 44% decrease in the flow of all new, trafficked guns to criminals in Milwaukee. The findings demonstrate the substantial impact that a single gun store's sales practices can have on the supply of new guns to criminals. Proposed anti-gun-trafficking efforts in other cities could benefit from targeting problem retail outlets. PMID:16937085

  13. Toward a terahertz-driven electron gun

    PubMed Central

    Huang, W. Ronny; Nanni, Emilio A.; Ravi, Koustuban; Hong, Kyung-Han; Fallahi, Arya; Wong, Liang Jie; Keathley, Phillip D.; Zapata, Luis E.; Kärtner, Franz X.

    2015-01-01

    Femtosecond electron bunches with keV energies and eV energy spread are needed by condensed matter physicists to resolve state transitions in carbon nanotubes, molecular structures, organic salts, and charge density wave materials. These semirelativistic electron sources are not only of interest for ultrafast electron diffraction, but also for electron energy-loss spectroscopy and as a seed for x-ray FELs. Thus far, the output energy spread (hence pulse duration) of ultrafast electron guns has been limited by the achievable electric field at the surface of the emitter, which is 10 MV/m for DC guns and 200 MV/m for RF guns. A single-cycle THz electron gun provides a unique opportunity to not only achieve GV/m surface electric fields but also with relatively low THz pulse energies, since a single-cycle transform-limited waveform is the most efficient way to achieve intense electric fields. Here, electron bunches of 50 fC from a flat copper photocathode are accelerated from rest to tens of eV by a microjoule THz pulse with peak electric field of 72 MV/m at 1 kHz repetition rate. We show that scaling to the readily-available GV/m THz field regime would translate to monoenergetic electron beams of ~100 keV. PMID:26486697

  14. 76 FR 70918 - Energy Conservation Program: Test Procedures for Residential Clothes Washers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-16

    ... DEPARTMENT OF ENERGY 10 CFR Parts 429 and 430 [Docket No. EERE-2010-BT-TP-0021] RIN 1904-AC08 Energy Conservation Program: Test Procedures for Residential Clothes Washers Correction In proposed rule document 2011-28543 appearing on pages 69870-69893 in the issue of November 9, 2011, make the following correction: On page 69870, in the first...

  15. Gun Violence, Mental Illness, And Laws That Prohibit Gun Possession: Evidence From Two Florida Counties

    PubMed Central

    Swanson, Jeffrey W.; Easter, Michele M.; Robertson, Allison G.; Swartz, Marvin S.; Alanis-Hirsch, Kelly; Moseley, Daniel; Dion, Charles; Petrila, John

    2016-01-01

    Gun violence kills about ninety people every day in the United States, a toll measured in wasted and ruined lives and with an annual economic price tag exceeding $200 billion. Some policy makers suggest that reforming mental health care systems and improving point-of-purchase background checks to keep guns from mentally disturbed people will address the problem. Epidemiological research shows that serious mental illness contributes little to the risk of interpersonal violence but is a strong factor in suicide, which accounts for most firearm fatalities. Meanwhile, the effectiveness of gun restrictions focused on mental illness remains poorly understood. This article examines gun-related suicide and violent crime in people with serious mental illnesses, and whether legal restrictions on firearm sales to people with a history of mental health adjudication are effective in preventing gun violence. Among the study population in two large Florida counties, we found that 62 percent of violent gun crime arrests and 28 percent of gun suicides involved individuals not legally permitted to have a gun at the time. Suggested policy reforms include enacting risk-based gun removal laws and prohibiting guns from people involuntarily detained in short-term psychiatric hospitalizations. PMID:27269024

  16. The Experimental Study of Novel Pseudospark Hollow Cathode Plasma Electron Gun

    NASA Astrophysics Data System (ADS)

    Gu, Xiaowei; Meng, Lin; Sun, Yiqin; Yu, Xinhua

    2008-11-01

    The high-power microwave devices with plasma-filled have unique properties. One of the major problems associated with plasma-filled microwave sources is that ions from the plasma drift toward the gun regions of the tube. This bombardment is particularly dangerous for the gun, where high-energy ion impacts can damage the cathode surface and degrade its electron emission capabilities. One of the techniques investigated to mitigate this issue is to replace the material cathode with plasma cathode. Now, we study the novel electron gun (E-gun) that can be suitable for high power microwave device applications, adopting two forms of discharge channel, 1: a single hole channel, the structure can produce a solid electron beam; 2: porous holes channel, the structure can generate multiple electronic injection which is similar to the annular electron beam.

  17. Gun Violence, Mental Illness, And Laws That Prohibit Gun Possession: Evidence From Two Florida Counties.

    PubMed

    Swanson, Jeffrey W; Easter, Michele M; Robertson, Allison G; Swartz, Marvin S; Alanis-Hirsch, Kelly; Moseley, Daniel; Dion, Charles; Petrila, John

    2016-06-01

    Gun violence kills about ninety people every day in the United States, a toll measured in wasted and ruined lives and with an annual economic price tag exceeding $200 billion. Some policy makers suggest that reforming mental health care systems and improving point-of-purchase background checks to keep guns from mentally disturbed people will address the problem. Epidemiological research shows that serious mental illness contributes little to the risk of interpersonal violence but is a strong factor in suicide, which accounts for most firearm fatalities. Meanwhile, the effectiveness of gun restrictions focused on mental illness remains poorly understood. This article examines gun-related suicide and violent crime in people with serious mental illnesses, and whether legal restrictions on firearm sales to people with a history of mental health adjudication are effective in preventing gun violence. Among the study population in two large Florida counties, we found that 62 percent of violent gun crime arrests and 28 percent of gun suicides involved individuals not legally permitted to have a gun at the time. Suggested policy reforms include enacting risk-based gun removal laws and prohibiting guns from people involuntarily detained in short-term psychiatric hospitalizations. Project HOPE—The People-to-People Health Foundation, Inc.

  18. Improved DC Gun and Insulator Assembly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neubauer, Michael

    Many user facilities such as synchrotron radiation light sources and free electron lasers rely on DC high voltage photoguns with internal field gradients as high as 10 to 15 MV/m. These high gradients often lead to field emission which poses serious problems for the photocathode used to generate the electron beam and the ceramic insulators used to bias the photocathode at high voltage. Ceramic insulators are difficult to manufacture, require long commissioning times, and have poor reliability, in part because energetic electrons bury themselves in the ceramic causing a buildup of charge and eventual puncture, and also because large diametermore » ceramics are difficult to braze reliably. The lifetimes of photo cathodes inside high current DC guns exhibiting field emission are limited to less than a hundred hours. Reducing the surface gradients on the metals reduces the field emission, which serves to maintain the required ultrahigh vacuum condition. A novel gun design with gradients around 5 MV/m and operating at 350 kV, a major improvement over existing designs, was proposed that allows for the in-situ replacement of photo cathodes in axially symmetric designs using inverted ceramics. In this project, the existing JLAB CEBAF asymmetric gun design with an inverted ceramic support was modeled and the beam dynamics characterized. An improved structure was designed that reduces the surface gradients and improves the beam optics. To minimize the surface gradients, a number of electrostatic gun designs were studied to determine the optimum configuration of the critical electrodes within the gun structure. Coating experiments were carried out to create a charge dissipative coating for cylindrical ceramics. The phase II proposal, which was not granted, included the design and fabrication of an axially symmetric DC Gun with an inverted ceramic that would operate with less than 5 MV/m at 350 kV and would be designed with an in-situ replaceable photo-cathode.« less

  19. Large Bore Powder Gun Qualification (U)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rabern, Donald A.; Valdiviez, Robert

    A Large Bore Powder Gun (LBPG) is being designed to enable experimentalists to characterize material behavior outside the capabilities of the NNSS JASPER and LANL TA-55 PF-4 guns. The combination of these three guns will create a capability to conduct impact experiments over a wide range of pressures and shock profiles. The Large Bore Powder Gun will be fielded at the Nevada National Security Site (NNSS) U1a Complex. The Complex is nearly 1000 ft below ground with dedicated drifts for testing, instrumentation, and post-shot entombment. To ensure the reliability, safety, and performance of the LBPG, a qualification plan has beenmore » established and documented here. Requirements for the LBPG have been established and documented in WE-14-TR-0065 U A, Large Bore Powder Gun Customer Requirements. The document includes the requirements for the physics experiments, the gun and confinement systems, and operations at NNSS. A detailed description of the requirements is established in that document and is referred to and quoted throughout this document. Two Gun and Confinement Systems will be fielded. The Prototype Gun will be used primarily to characterize the gun and confinement performance and be the primary platform for qualification actions. This gun will also be used to investigate and qualify target and diagnostic modifications through the life of the program (U1a.104 Drift). An identical gun, the Physics Gun, will be fielded for confirmatory and Pu experiments (U1a.102D Drift). Both guns will be qualified for operation. The Gun and Confinement System design will be qualified through analysis, inspection, and testing using the Prototype Gun for the majority of process. The Physics Gun will be qualified through inspection and a limited number of qualification tests to ensure performance and behavior equivalent to the Prototype gun. Figure 1.1 shows the partial configuration of U1a and the locations of the Prototype and Physics Gun/Confinement Systems.« less

  20. Gun carrying by high school students in Boston, MA: does overestimation of peer gun carrying matter?

    PubMed

    Hemenway, David; Vriniotis, Mary; Johnson, Renee M; Miller, Matthew; Azrael, Deborah

    2011-10-01

    This paper investigates: (1) whether high school students overestimate gun carrying by their peers, and (2) whether those students who overestimate peer gun carrying are more likely to carry firearms. Data come from a randomly sampled survey conducted in 2008 of over 1,700 high school students in Boston, MA. Over 5% of students reported carrying a gun, 9% of boys and 2% of girls. Students substantially overestimated the percentage of their peers who carried guns; the likelihood that a respondent carried a gun was strongly associated with their perception of the level of peer gun carrying. Most respondents believed it was easier for other youth to obtain guns than it was for them. Social marketing campaigns designed to lower young people's perceptions about the prevalence of peer gun carrying may be a promising strategy for reducing actual gun carrying among youth. Copyright © 2010 The Foundation for Professionals in Services for Adolescents. Published by Elsevier Ltd. All rights reserved.

  1. Optimizing RF gun cavity geometry within an automated injector design system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alicia Hofler ,Pavel Evtushenko

    2011-03-28

    RF guns play an integral role in the success of several light sources around the world, and properly designed and optimized cw superconducting RF (SRF) guns can provide a path to higher average brightness. As the need for these guns grows, it is important to have automated optimization software tools that vary the geometry of the gun cavity as part of the injector design process. This will allow designers to improve existing designs for present installations, extend the utility of these guns to other applications, and develop new designs. An evolutionary algorithm (EA) based system can provide this capability becausemore » EAs can search in parallel a large parameter space (often non-linear) and in a relatively short time identify promising regions of the space for more careful consideration. The injector designer can then evaluate more cavity design parameters during the injector optimization process against the beam performance requirements of the injector. This paper will describe an extension to the APISA software that allows the cavity geometry to be modified as part of the injector optimization and provide examples of its application to existing RF and SRF gun designs.« less

  2. Back-bombardment compensation in microwave thermionic electron guns

    NASA Astrophysics Data System (ADS)

    Kowalczyk, Jeremy M. D.; Madey, John M. J.

    2014-12-01

    The development of capable, reliable, and cost-effective compact electron beam sources remains a long-standing objective of the efforts to develop the accelerator systems needed for on-site research and industrial applications ranging from electron beam welding to high performance x-ray and gamma ray light sources for element-resolved microanalysis and national security. The need in these applications for simplicity, reliability, and low cost has emphasized solutions compatible with the use of the long established and commercially available pulsed microwave rf sources and L-, S- or X-band linear accelerators. Thermionic microwave electron guns have proven to be one successful approach to the development of the electron sources for these systems providing high macropulse average current beams with picosecond pulse lengths and good emittance out to macropulse lengths of 4-5 microseconds. But longer macropulse lengths are now needed for use in inverse-Compton x-ray sources and other emerging applications. We describe in this paper our approach to extending the usable macropulse current and pulse length of these guns through the use of thermal diffusion to compensate for the increase in cathode surface temperature due to back-bombardment.

  3. Goods for Guns--the use of a gun buyback as an injury prevention/community education tool.

    PubMed

    McGuire, Margaret; Manno, Mariann; Rook, Allison; Maranda, Louise; Renaud, Elizabeth; DeRoss, Anthony; Hirsh, Michael

    2011-11-01

    US children aged between 5 years and 14 years have a rate of gun-related homicide 17 times higher and a rate of gun-related suicide and unintentional firearm injury 10 times higher than other developed countries. Gun buyback programs have been criticized as ineffective interventions in decreasing violence. The Injury Free Coalition for Kids-Worcester (IFCK-W) Goods for Guns buyback is a multipronged approach to address these concerns and to reduce the number of firearms in the community. The IFCK-W buyback program is funded by corporate sponsors, grants, and individual donations. Citizens are instructed to transport guns, ammunition, and weapons safely to police headquarters on two Saturdays in December. Participants are guaranteed anonymity by the District Attorney's office and receive gift certificates for operable guns. Trained volunteers administer an anonymous survey to willing participants. Individuals who disclose having unsafely stored guns remaining at home receive educational counseling and trigger locks. Guns and ammunition are destroyed at a later time in a gun crushing ceremony. Since 2002, 1,861 guns (444 rifle/shotgun, 738 pistol/revolver, and 679 automatic/semiautomatic) have been collected at a cost of $99,250 (average, $53/gun). Seven hundred ten people have surrendered firearms, 534 surveys have been administered, and ≈ 75 trigger locks have been distributed per year. IFCK-W Goods for Guns is a relatively inexpensive injury prevention model program that removes unwanted firearms from homes, raises community awareness about gun safety, and provides high-risk individuals with trigger locks and educational counseling.

  4. The effects of pulse pressure from seismic water gun technology on Northern Pike

    USGS Publications Warehouse

    Gross, Jackson A.; Irvine, Kathryn M.; Wilmoth, Siri K.; Wagner, Tristany L.; Shields, Patrick A; Fox, Jeffrey R.

    2013-01-01

    We examined the efficacy of sound pressure pulses generated from a water gun for controlling invasive Northern Pike Esox lucius. Pulse pressures from two sizes of water guns were evaluated for their effects on individual fish placed at a predetermined random distance. Fish mortality from a 5,620.8-cm3 water gun (peak pressure source level = 252 dB referenced to 1 μP at 1 m) was assessed every 24 h for 168 h, and damage (intact, hematoma, or rupture) to the gas bladder, kidney, and liver was recorded. The experiment was replicated with a 1,966.4-cm3 water gun (peak pressure source level = 244 dB referenced to 1 μP at 1 m), but fish were euthanized immediately. The peak sound pressure level (SPLpeak), peak-to-peak sound pressure level (SPLp-p), and frequency spectrums were recorded, and the cumulative sound exposure level (SELcum) was subsequently calculated. The SPLpeak, SPLp-p, and SELcum were correlated, and values varied significantly by treatment group for both guns. Mortality increased and organ damage was greater with decreasing distance to the water gun. Mortality (31%) by 168 h was only observed for Northern Pike exhibiting the highest degree of organ damage. Mortality at 72 h and 168 h postexposure was associated with increasing SELcum above 195 dB. The minimum SELcum calculated for gas bladder rupture was 199 dB recorded at 9 m from the 5,620.8-cm3 water gun and 194 dB recorded at 6 m from the 1,966.4-cm3water gun. Among Northern Pike that were exposed to the large water gun, 100% of fish exposed at 3 and 6 m had ruptured gas bladders, and 86% exposed at 9 m had ruptured gas bladders. Among fish that were exposed to pulse pressures from the smaller water gun, 78% exhibited gas bladder rupture. Results from these initial controlled experiments underscore the potential of water guns as a tool for controlling Northern Pike.

  5. Impedance-Based Pre-Stress Monitoring of Rock Bolts Using a Piezoceramic-Based Smart Washer-A Feasibility Study.

    PubMed

    Wang, Bo; Huo, Linsheng; Chen, Dongdong; Li, Weijie; Song, Gangbing

    2017-01-27

    Pre-stress degradation or looseness of rock bolts in mining or tunnel engineering threatens the stability and reliability of the structures. In this paper, an innovative piezoelectric device named a "smart washer" with the impedance method is proposed with the aim of developing a real-time device to monitor the pre-stress level of rock bolts. The proposed method was verified through tests on a rock bolt specimen. By applying high-frequency sweep excitations (typically >30 kHz) to the smart washer that was installed on the rock bolt specimen, we observed that the variation in impedance signatures indicated the rock bolt pre-stress status. With the degradation of rock bolt pre-stress, the frequency in the dominating peak of the real part of the electrical impedance signature increased. To quantify the effectiveness of the proposed technique, a normalized root mean square deviation (RMSD) index was developed to evaluate the degradation level of the rock bolt pre-stress. The experimental results demonstrated that the normalized RMSD-based looseness index, which was computed from the impedance value detected by the "smart washer", increased with loss of the pre-stress of the rock bolt. Therefore, the proposed method can effectively detect the degradation of rock bolt pre-stress, as demonstrated by experiments.

  6. Simplified pipe gun

    NASA Astrophysics Data System (ADS)

    Sørensen, H.; Nordskov, A.; Sass, B.; Visler, T.

    1987-12-01

    A simplified version of a deuterium pellet gun based on the pipe gun principle is described. The pipe gun is made from a continuous tube of stainless steel and gas is fed in from the muzzle end only. It is indicated that the pellet length is determined by the temperature gradient along the barrel right outside the freezing cell. Velocities of around 1000 m/s with a scatter of ±2% are obtained with a propellant gas pressure of 40 bar.

  7. Gun Attitudes and Fear of Crime.

    ERIC Educational Resources Information Center

    Heath, Linda; Weeks, Kyle; Murphy, Marie Mackay

    1997-01-01

    Using three studies, examined the relationship between attitudes toward guns and fear of crime. Findings indicate a connection between fear of crime and attitudes toward guns: people higher in fear of crime favored gun control. Results also established a relationship between stereotypical beliefs about gun victims and support for gun control. (RJM)

  8. Numerical modelling of the CEBAF electron gun with EGUN

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Philippe Liger; Geoffrey Krafft

    1990-09-10

    The electron source used in the injector for the CEBAF accelerator is a Hermosa electron gun with a 2 mm diameter cathode and a control electrode. It produces a 100 keV electron beam to be focused on the first of two apertures which comprise an emittance filter. A normalized emittance of less than {pi} mm mrad at 1.2 mA is set by the requirements of the final beam from the CEBAF linac, since downstream of the filter, a system of two choppers and a third aperture removes 5/6 of the current. In addition, for RF test purposes a higher currentmore » of about 5 mA is needed, possibly at higher emittance. This paper presents a way of calculating the characteristics of the CEBAF electron gun with the gun design code EGUN, and the accuracy of the results is discussed. The transverse shape of the beam delivered by the gun has been observed, and its current measured. A halo around the beam has been seen, and the calculations can reproduce this effect.« less

  9. The case for moderate gun control.

    PubMed

    DeGrazia, David

    2014-03-01

    In addressing the shape of appropriate gun policy, this essay assumes for the sake of discussion that there is a legal and moral right to private gun ownership. My thesis is that, against the background of this right, the most defensible policy approach in the United States would feature moderate gun control. The first section summarizes the American gun control status quo and characterizes what I call "moderate gun control." The next section states and rebuts six leading arguments against this general approach to gun policy. The section that follows presents a positive case for moderate gun control that emphasizes safety in the home and society as well as rights whose enforcement entails some limits or qualifications on the right to bear arms. A final section shows how the recommended gun regulations address legitimate purposes, rather than imposing arbitrary restrictions on gun rights, and offers concluding reflections.

  10. University of Maryland Wall Washer Retrofit - LED Modules Replace Halogen Lamps in a Performing Arts Center

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilkerson, Andrea M.; Abell, Thomas C.; Perrin, Tess E.

    The University of Maryland (UMD) began retrofitting halogen wall washers in the Clarice Smith Performing Arts Center (CSPAC) in April 2014. The U.S. Department of Energy (DOE) Solid-State Lighting (SSL) GATEWAY program documented this process through the final installation in March 2015, summarized in this report. The wall washers illuminate hallways lining the atrium, providing task illuminance for transitioning between spaces and visual interest to the atrium boundaries. The main goals of the retrofit were to maintain the visual appearance of the space while reducing maintenance costs – energy savings was considered an additional benefit by UMD Facilities Management. UMDmore » Facilities Management is pleased with the results of this retrofit, and continues to initiate LED retrofit projects across the UMD campus.« less

  11. Long-Life/Low-Power Ion-Gun Cathode

    NASA Technical Reports Server (NTRS)

    Fitzgerald, D. J.

    1982-01-01

    New cathode has form of hollow tube through which gas enters region of high electron density, produced by electric discharge with auxiliary electrode referred to as "keeper." Ion-gun cathode emits electrons that bombard gas in chamber. Ions accelerated out of source are used to dope semiconductor material.

  12. RF study and 3-D simulations of a side-coupling thermionic RF-gun

    NASA Astrophysics Data System (ADS)

    Rimjaem, S.; Kusoljariyakul, K.; Thongbai, C.

    2014-02-01

    A thermionic RF-gun for generating ultra-short electron bunches was optimized, developed and used as a source at a linac-based THz radiation research laboratory of the Plasma and Beam Physics Research Facility, Chiang Mai University, Thailand. The RF-gun is a π/2-mode standing wave structure, which consists of two S-band accelerating cells and a side-coupling cavity. The 2856 MHz RF wave is supplied from an S-band klystron to the gun through the waveguide input-port at the cylindrical wall of the second cell. A fraction of the RF power is coupled from the second cell to the first one via a side-coupling cavity. Both the waveguide input-port and the side-coupling cavity lead to an asymmetric geometry of the gun. RF properties and electromagnetic field distributions inside the RF-gun were studied and numerically simulated by using computer codes SUPERFISH 7.19 and CST Microwave Studio 2012©. RF characterizations and tunings of the RF-gun were performed to ensure the reliability of the gun operation. The results from 3D simulations and measurements are compared and discussed in this paper. The influence of asymmetric field distributions inside the RF-gun on the electron beam properties was investigated via 3D beam dynamics simulations. A change in the coupling-plane of the side-coupling cavity is suggested to improve the gun performance.

  13. Commissioning Results of the 2nd 3.5 Cell SRF Gun for ELBE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arnold, A; Freitag, M; Murcek, Petr

    As in 2007 the first 3.5 cell superconducting radio frequency (SRF) gun was taken into operation, it turned out that the specified performance has not been achieved. However, to demonstrate the full potential of this new type of electron source, a second and slightly modified SRF gun II was built in collaboration with Thomas Jefferson National Accelerator Facility (TJNAF). We will report on commissioning and first results of the new gun, which includes in particular the characterization of the most important RF properties as well as their comparison with previous vertical test results.

  14. NASA Researcher with a Coaxial Plasma Gun

    NASA Image and Video Library

    1962-06-21

    Researcher Charles Michels operates a coaxial plasma gun rig in Cell SW-13 of the Engine Research Building at the National Aeronautics and Space Administration (NASA) Lewis Research Center. From 1962 to 1967 NASA Lewis investigated coaxial plasma guns powered by conventional capacitor banks. The studies were part of a larger effort to identify electromagnetic accelerators for space propulsion. NASA worked with General Dynamics, General Electric, General Motors, and Republic Aviation on the project. NASA Lewis conducted a research program to determine which factors influenced the coaxial gun’s efficiency and analyze the acceleration process. The system had not previously been used for propulsion applications. The single-shot gun’s fast gas valve and capacitor banks with variable-delay ignition source permitted the evaluation of gun performance under controllable propellant quantity and distribution conditions. The coaxial plasma gun was the most basic type of electromagnetic accelerator. It included a charged capacitor in series with a pair of coaxial electrodes. An electrical breakdown occurred when gas was admitted to the inter-electrode region. The gas instantly became a good conductor and formed a conducting sheet that separated the magnetic field from the open region beyond. The highly-conducting gas was basically expelled by the force of the magnetic pressure. This type of thruster could operate at the high instantaneous power levels without decreasing its average power level.

  15. Unbalanced field RF electron gun

    DOEpatents

    Hofler, Alicia

    2013-11-12

    A design for an RF electron gun having a gun cavity utilizing an unbalanced electric field arrangement. Essentially, the electric field in the first (partial) cell has higher field strength than the electric field in the second (full) cell of the electron gun. The accompanying method discloses the use of the unbalanced field arrangement in the operation of an RF electron gun in order to accelerate an electron beam.

  16. Note: O-ring stack system for electron gun alignment.

    PubMed

    Park, In-Yong; Cho, Boklae; Han, Cheolsu; Shin, Seungmin; Lee, Dongjun; Ahn, Sang Jung

    2015-01-01

    We present a reliable method for aligning an electron gun which consists of an electron source and lenses by controlling a stack of rubber O-rings in a vacuum condition. The beam direction angle is precisely tilted along two axes by adjusting the height difference of a stack of O-rings. In addition, the source position is shifted in each of three orthogonal directions. We show that the tilting angle and linear shift along the x and y axes as obtained from ten stacked O-rings are ±2.55° and ±2 mm, respectively. This study can easily be adapted to charged particle gun alignment and adjustments of the flange position in a vacuum, ensuring that its results can be useful with regard to electrical insulation between flanges with slight modifications.

  17. An ultrafast nanotip electron gun triggered by grating-coupled surface plasmons

    NASA Astrophysics Data System (ADS)

    Schröder, Benjamin; Sivis, Murat; Bormann, Reiner; Schäfer, Sascha; Ropers, Claus

    2015-12-01

    We demonstrate multiphoton photoelectron emission from gold nanotips induced by nanofocusing surface plasmons, resonantly excited on the tip shaft by a grating coupler. The tip is integrated into an electron gun assembly, which facilitates control over the spatial emission sites and allows us to disentangle direct grating emission from plasmon-triggered apex emission. The nanoscale source size of this electron gun concept enables highly coherent electron pulses with applications in ultrafast electron imaging and diffraction.

  18. An ultrafast nanotip electron gun triggered by grating-coupled surface plasmons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schröder, Benjamin; Sivis, Murat; Bormann, Reiner

    We demonstrate multiphoton photoelectron emission from gold nanotips induced by nanofocusing surface plasmons, resonantly excited on the tip shaft by a grating coupler. The tip is integrated into an electron gun assembly, which facilitates control over the spatial emission sites and allows us to disentangle direct grating emission from plasmon-triggered apex emission. The nanoscale source size of this electron gun concept enables highly coherent electron pulses with applications in ultrafast electron imaging and diffraction.

  19. From gun politics to self-defense politics: a feminist critique of the great gun debate.

    PubMed

    Carlson, Jennifer D

    2014-03-01

    This article calls attention to a problematic binary produced by public debates surrounding gun rights and gun control-namely, that women must choose armed self-protection or no self-protection at all. I argue that both anti- and pro-gun discourses, drawing on and reproducing race and class privileges, use assumptions about women's physical inferiority to further their agendas. I highlight how both sides have used guns as the proxy for self-defense and conclude by calling for a shift in public discourse to focus on the broader question of the right to self-defense rather than the narrower question of gun rights.

  20. RF Design of the LCLS Gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Limborg-Deprey, C

    Final dimensions for the LCLS RF gun are described. This gun, referred to as the LCLS gun, is a modified version of the UCLA/BNL/SLAC 1.6 cell S-Band RF gun [1], referred to as the prototype gun. The changes include a larger mode separation (15 MHz for the LCLS gun vs. 3.5 MHz for the prototype gun), a larger radius at the iris between the 2 cells, a reduced surface field on the curvature of the iris between the two cells, Z power coupling, increased cooling channels for operation at 120 Hz, dual rf feed, deformation tuning of the full cell,more » and field probes in both cells. Temporal shaping of the klystron pulse, to reduce the average power dissipated in the gun, has also been adopted. By increasing the mode separation, the amplitude of the 0-mode electric field on the cathode decreases from 10% of the peak on axis field for the prototype gun to less than 3% for the LCLS gun for the steady state fields. Beam performance is improved as shown by the PARMELA simulations. The gun should be designed to accept a future load lock system. Modifications follow the recommendations of our RF review committee [2]. Files and reference documents are compiled in Section IV.« less

  1. 78 FR 11154 - Large Residential Washers From the Republic of Korea: Countervailing Duty Order

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-15

    ... externally mounted steel frame at least six inches high that is designed to house a coin/token operated... ``stacked washer-dryers'' denotes distinct washing and drying machines that are built on a unitary frame and... of steel and is assembled with security fasteners;\\8\\ or \\7\\ ``Payment system electronics'' denotes a...

  2. Initial Beam Dynamics Simulations of a High-Average-Current Field-Emission Electron Source in a Superconducting RadioFrequency Gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mohsen, O.; Gonin, I.; Kephart, R.

    High-power electron beams are sought-after tools in support to a wide array of societal applications. This paper investigates the production of high-power electron beams by combining a high-current field-emission electron source to a superconducting radio-frequency (SRF) cavity. We especially carry out beam-dynamics simulations that demonstrate the viability of the scheme to formmore » $$\\sim$$ 300 kW average-power electron beam using a 1+1/2-cell SRF gun.« less

  3. The life cycle of crime guns: a description based on guns recovered from young people in California.

    PubMed

    Wintemute, Garen J; Romero, Michael P; Wright, Mona A; Grassel, Kevin M

    2004-06-01

    We describe the life cycle of crime guns recovered from young people-the movement of those guns from manufacture to criminal use-and identify associations between the characteristics of those guns and their possessors, purchasers, sellers, and places of origin. This is a cross-sectional study of data from gun ownership tracing records compiled by the Bureau of Alcohol, Tobacco, Firearms and Explosives for 2,121 crime guns recovered in California from persons younger than 25 years and traced in 1999. Purchaser and seller data for handguns were updated when possible by linking to California handgun sales records. The 2,121 traced guns were recovered from 1,717 young people. Guns recovered from persons aged 21 to 24 years were most frequently also purchased by persons aged 21 to 24 years; those recovered from persons younger than 18 years were most often purchased by persons aged 45 years or older. Small-caliber handguns made up 41.0% of handguns recovered from persons younger than 18 years but 25.2% of handguns recovered from persons aged 21 to 24 years. The median time from sale to recovery (commonly called time to crime) for all guns was 6.4 years (interquartile range 2.7 to 12.4 years). A time to crime of less than 3 years, suggesting deliberate gun trafficking, was observed for 17.3% of guns recovered from persons younger than 18 years but 34.6% of guns recovered from persons aged 21 to 24 years. Ten retailers who sold 10 or more traced guns accounted for 13.1% of all guns traced to a retailer. Handguns whose purchaser and possessor were the same person were more likely than others to be large-caliber semiautomatic pistols (29.3% and 11.7%, respectively); their median time to crime was 0.2 years (69 days). Analysis of crime-gun ownership traces reveals patterns that may help refine gun violence prevention efforts and render them more effective.

  4. Evaluation of cleaning and disinfection performance of automatic washer disinfectors machines in programs presenting different cycle times and temperatures.

    PubMed

    Bergo, Maria do Carmo Noronha Cominato

    2006-01-01

    Thermal washer-disinfectors represent a technology that brought about great advantages such as, establishment of protocols, standard operating procedures, reduction in occupational risk of a biological and environmental nature. The efficacy of the cleaning and disinfection obtained by automatic washer disinfectors machines in running programs with different times and temperatures determined by the different official agencies was validated according to recommendations from ISO Standards 15883-1/1999 and HTM2030 (NHS Estates, 1997) for the determining of the Minimum Lethality and DAL both theoretically and through the use with thermocouples. In order to determine the cleaning efficacy, the Soil Test, Biotrace Pro-tect and the Protein Test Kit were used. The procedure to verify the CFU count of viable microorganisms was performed before and after the thermal disinfection. This article shows that the results are in compliance with the ISO and HTM Standards. The validation steps confirmed the high efficacy level of the Medical Washer-Disinfectors. This protocol enabled the evaluation of the procedure based on evidence supported by scientific research, aiming at the support of the Supply Center multi-professional personnel with information and the possibility of developing further research.

  5. WashWise cleans up the Northwest: Lessons learned from the Northwest high-efficiency clothes washer initiative

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gordon, L.M.; Banks, D.L.; Brenneke, M.E.

    1998-07-01

    WashWise is a regional market transformation program designed to promote the sale and acceptance or resource-efficient clothes washers (RECWs) in the Northwest through financial incentives, education, and marketing. The Program is sponsored by the Northwest Energy Efficiency Alliance (the Alliance), a non-profit regional consortium of utilities, government, public interest groups, and private sector organizations. WashWise started in May 1997 and will continue through the end of 1999. WashWise works to transform the clothes washer market primarily at the retail level through an in-store instant rebate and a retailer bonus. In addition to financial incentives, WashWise has undertaken a collaborative marketingmore » and promotional campaign to educate consumers about the financial savings and other benefits of RECWs. The program promotes only RECWs that meet strict energy and water savings criteria. WashWise has far exceeded initial expectations; annual program sales goals were met in the first three months. As of June 1998, 30,000 RECWs have been sold through the program (representing approximately 13 percent of the Northwest residential clothes washer market). In addition, over 540 retailers, including national and regional chains, are participating in the program. Preliminary survey results also have also provided evidence of broad customer satisfaction. This paper reviews the key elements that have contributed to the success of the WashWise program. In addition, the paper provides program results and indicates future directions for WashWise and the RECW market.« less

  6. 77 FR 37834 - Revocation of Certain Requirements Pertaining to Caps Intended for Use With Toy Guns and Toy Guns...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-25

    ... Certain Requirements Pertaining to Caps Intended for Use With Toy Guns and Toy Guns Not Intended for Use... compliance than our existing regulations pertaining to caps intended for use with toy guns and toy guns not... regulations pertaining to caps intended for use with toy guns and toy guns not intended for use with caps...

  7. 76 FR 49237 - Energy Conservation Program: Test Procedures for Residential Clothes Washers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-09

    ...In this supplemental notice of proposed rulemaking (SNOPR), the U.S. Department of Energy (DOE) proposes to revise its test procedure for residential clothes washers established under the Energy Policy and Conservation Act (EPCA). DOE proposes to incorporate provisions of the International Electrotechnical Commission (IEC) Standard 62301, ``Household electrical appliances--Measurement of standby power'' (Second Edition). DOE also proposes to update the provisions for measuring active mode energy and water consumption.

  8. Magnetron Electron Gun,

    DTIC Science & Technology

    1980-05-23

    ULMAGNETRON ELECTRON GUN . (U) .Ay G0 A L GOLOENBERG, T B PANKRATOVA UNCLASSIFIED FTD..In(RS)T41896-?9 4 __ ihD - -111113 MICROCOPY RESOLUTION TEST...CHART NATIONAL BUREAU OF STANDARD 1961 A -_"D-I-D ,RS)T-18q6-79 v FOREIGN TECHNOLOGY DIVISION MAGNETRON ELECTRON GUN by A. L. Gol’denberg, T. B...VISION. WP.AP6. OHIO. FTD -ID(RS)T-1396-79 Date z.-.:a’,-lq -,o • 110ewm /A Is a, -D r.l MAGNETRON ELECTRON GUN A. L. Gol’denberg, T. B. Pankratova and M

  9. Self-bunching electron guns

    NASA Astrophysics Data System (ADS)

    Mako, Frederick M.; Len, L. K.

    1999-05-01

    We report on three electron gun projects that are aimed at power tube and injector applications. The purpose of the work is to develop robust electron guns which produce self-bunched, high-current-density beams. We have demonstrated, in a microwave cavity, self-bunching, cold electron emission, long life, and tolerance to contamination. The cold process is based on secondary electron emission. FMT has studied using simulation codes the resonant bunching process which gives rise to high current densities (0.01-5 kA/cm2), high charge bunches (up to 500 nC/bunch), and short pulses (1-100 ps) for frequencies from 1 to 12 GHz. The beam pulse width is nominally ˜5% of the rf period. The first project is the L-Band Micro-Pulse Gun (MPG). Measurements show ˜40 ps long micro-bunches at ˜20 A/cm2 without contamination due to air exposure. Lifetime testing has been carried out for about 18 months operating at 1.25 GHz for almost 24 hours per day at a repetition rate of 300 Hz and 5 μs-long macro-pulses. Approximately 5.8×1013 micro-bunches or 62,000 coulombs have passed through this gun and it is still working fine. The second project, the S-Band MPG, is now operational. It is functioning at a frequency of 2.85 GHz, a repetition rate of 30 Hz, with a 2 μs-long macro-pulse. It produces about 45 A in the macro-pulse. The third project is a 34.2 GHz frequency-multiplied source driven by an X-Band MPG. A point design was performed at an rf output power of 150 MW at 34.2 GHz. The resulting system efficiency is 53% and the gain is 60 dB. The system efficiency includes the input cavity efficiency, input driver efficiency (a 50 MW klystron at 11.4 GHz), output cavity efficiency, and the post-acceleration efficiency.

  10. Effects of undercover police stings of gun dealers on the supply of new guns to criminals

    PubMed Central

    Webster, D W; Bulzacchelli, M T; Zeoli, A M; Vernick, J S

    2006-01-01

    Objective To assess the effects of undercover police stings and lawsuits against gun dealers suspected of facilitating illegal gun sales in three US cities (Chicago, Detroit, Gary) on the flow of new firearms to criminals. Methods An interrupted time series design and negative binomial regression analyses were used to test for temporal change in the recovery of guns used in crimes within one year of retail sale in both intervention and comparison cities. Results The stings were associated with an abrupt 46.4% reduction in the flow of new guns to criminals in Chicago (95% confidence interval, −58.6% to −30.5%), and with a gradual reduction in new crime guns recovered in Detroit. There was no significant change associated with the stings in Gary, and no change in comparison cities that was coincident with the stings in Chicago and Detroit. Conclusions The announcement of police stings and lawsuits against suspect gun dealers appeared to have reduced the supply of new guns to criminals in Chicago significantly, and may have contributed to beneficial effects in Detroit. Given the important role that gun stores play in supplying guns to criminals in the US, further efforts of this type are warranted and should be evaluated. PMID:16887943

  11. Keeping Naval Guns Ready

    DTIC Science & Technology

    2016-03-01

    Keeping Naval Guns Ready David L. Rogers Rogers is the Deputy Department Head, Systems Integration Department, Naval Surface Warfare Center Indian...maritime routes and the global economy. This protection depends on keeping these forward naval ships ready, par- ticularly their guns and ammunition...the weapons of choice for counter- ing a multitude of threats. That gun readiness is assured with responsive technical support. It is done fast, and

  12. Gun trauma and ophthalmic outcomes.

    PubMed

    Chopra, N; Gervasio, K A; Kalosza, B; Wu, A Y

    2018-04-01

    PurposeThis retrospective cohort study assesses the visual outcomes of patients who survive gunshot wounds to the head.MethodsThe Elmhurst City Hospital Trauma Registry and Mount Sinai Data Warehouse were queried for gun trauma resulting in ocular injury over a 16-year period. Thirty-one patients over 16 years of age were found who suffered a gunshot wound to the head and resultant ocular trauma: orbital fracture, ruptured globe, foreign body, or optic nerve injury. Gun types included all firearms and air guns. Nine patients were excluded due to incorrect coding or unavailable charts. Statistical analysis was performed using a simple bivariate analysis (χ 2 ).ResultsOf the 915 victims of gun trauma to the head, 27 (3.0%) sustained ocular injuries. Of the 22 patients whose records were accessible, 18 survived. Eight of the 18 surviving patients (44%) suffered long-term visual damage, defined as permanent loss of vision in at least one eye to the level of counting fingers or worse. Neither location of injury (P=0.243), nor type of gun used (P=0.296), nor cause of gun trauma (P=0.348) predicted visual loss outcome. The Glasgow Coma Scale eye response score on arrival to the hospital also did not predict visual loss outcome (P=0.793).ConclusionThere has been a dearth of research into gun trauma and even less research on the visual outcomes following gun trauma. Our study finds that survivors of gun trauma to the head suffer long-term visual damage 44% of the time after injury.

  13. Loaded: Gun involvement among opioid users.

    PubMed

    Stein, Michael D; Kenney, Shannon R; Anderson, Bradley J; Bailey, Genie L

    2018-06-01

    Despite ample research examining how alcohol use relates to gun involvement, little is known about the relationship between opioids and gun involvement. In the current study, we examined correlates of gun possession, accessibility, and related behaviors in an opioid dependent sample. Between October 2016 and April 2017, we surveyed persons entering a brief, inpatient opioid detoxification (n = 386) and 51 contemporaneous persons seeking alcohol detoxification at the same facility in Massachusetts and recorded their lifetime experiences with gun involvement. Participants averaged 33 years of age, 74% were male, 83% were White, and 64% had a history of incarceration. Opioid users had significantly higher rates of gun involvement than persons in alcohol detoxification; for example, 31.3% (vs. 3.9%) had carried a gun for protection, 45.1% (vs. 25.5%) had been threatened with a gun, and 13.8% (vs. 2.0%) had shot at another person. Among persons misusing opioids, male and non-White respondents, and those with a history of incarceration or poorer self-control reported greater gun involvement. Opioid users, both men and women, lead gun-involved lives. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Revisiting Pneumatic Nail Gun Trigger Recommendations

    PubMed Central

    Albers, James; Lipscomb, Hester; Hudock, Stephen; Dement, John; Evanoff, Bradley; Fullen, Mark; Gillen, Matt; Kaskutas, Vicki; Nolan, James; Patterson, Dennis; Platner, James; Pompeii, Lisa; Schoenfisch, Ashley

    2015-01-01

    Summary Use of a pneumatic nail gun with a sequential actuation trigger (SAT) significantly diminishes the risk for acute traumatic injury compared to use of a contact actuation trigger (CAT) nail gun. A theoretically-based increased risk of work-related musculoskeletal disorders from use of a SAT nail gun, relative to CAT, appears unlikely and remains unproven. Based on current knowledge, the use of CAT nail guns cannot be justified as a safe alternative to SAT nail guns. This letter provides a perspective of ergonomists and occupational safety researchers recommending the use of the sequential actuation trigger for all nail gun tasks in the construction industry. PMID:26366020

  15. Revisiting Pneumatic Nail Gun Trigger Recommendations.

    PubMed

    Albers, James; Lowe, Brian; Lipscomb, Hester; Hudock, Stephen; Dement, John; Evanoff, Bradley; Fullen, Mark; Gillen, Matt; Kaskutas, Vicki; Nolan, James; Patterson, Dennis; Platner, James; Pompeii, Lisa; Schoenfisch, Ashley

    2015-03-01

    Use of a pneumatic nail gun with a sequential actuation trigger (SAT) significantly diminishes the risk for acute traumatic injury compared to use of a contact actuation trigger (CAT) nail gun. A theoretically-based increased risk of work-related musculoskeletal disorders from use of a SAT nail gun, relative to CAT, appears unlikely and remains unproven. Based on current knowledge, the use of CAT nail guns cannot be justified as a safe alternative to SAT nail guns. This letter provides a perspective of ergonomists and occupational safety researchers recommending the use of the sequential actuation trigger for all nail gun tasks in the construction industry.

  16. Children, Youth, and Gun Violence.

    ERIC Educational Resources Information Center

    Behrman, Richard E., Ed.

    2002-01-01

    This collection of articles summarizes knowledge and research about how gun violence affects children and youth and discusses which policies hold promise for reducing youth gun violence. The papers are: (1) "Statement of Purpose" (Richard E. Behrman); "Children, Youth, and Gun Violence: Analysis and Recommendations" (Kathleen…

  17. Note: O-ring stack system for electron gun alignment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, In-Yong; Cho, Boklae; Han, Cheolsu

    We present a reliable method for aligning an electron gun which consists of an electron source and lenses by controlling a stack of rubber O-rings in a vacuum condition. The beam direction angle is precisely tilted along two axes by adjusting the height difference of a stack of O-rings. In addition, the source position is shifted in each of three orthogonal directions. We show that the tilting angle and linear shift along the x and y axes as obtained from ten stacked O-rings are ±2.55° and ±2 mm, respectively. This study can easily be adapted to charged particle gun alignmentmore » and adjustments of the flange position in a vacuum, ensuring that its results can be useful with regard to electrical insulation between flanges with slight modifications.« less

  18. Preventing gun injuries in children.

    PubMed

    Crossen, Eric J; Lewis, Brenna; Hoffman, Benjamin D

    2015-02-01

    Firearms are involved in the injury and death of a large number of children each year from both intentional and unintentional causes. Gun ownership in homes with children is common, and pediatricians should incorporate evidence-based means to discuss firearms and protect children from gun-related injuries and violence. Safe storage of guns, including unloaded guns locked and stored separately from ammunition, can decrease risks to children, and effective tools are available that pediatricians can use in clinical settings to help decrease children's access to firearms. Furthermore, several community-based interventions led by pediatricians have effectively reduced firearm-related injury risks to children. Educational programs that focus on children's behavior around guns have not proven effective. © American Academy of Pediatrics, 2015. All rights reserved.

  19. Integrated numerical modeling of a laser gun injector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, H.; Benson, S.; Bisognano, J.

    1993-06-01

    CEBAF is planning to incorporate a laser gun injector into the linac front end as a high-charge cw source for a high-power free electron laser and nuclear physics. This injector consists of a DC laser gun, a buncher, a cryounit and a chicane. The performance of the injector is predicted based on integrated numerical modeling using POISSON, SUPERFISH and PARMELA. The point-by-point method incorporated into PARMELA by McDonald is chosen for space charge treatment. The concept of ``conditioning for final bunching`` is employed to vary several crucial parameters of the system for achieving highest peak current while maintaining low emittancemore » and low energy spread. Extensive parameter variation studies show that the design will perform beyond the specifications for FEL operations aimed at industrial applications and fundamental scientific research. The calculation also shows that the injector will perform as an extremely bright cw electron source.« less

  20. BEAM DYNAMICS SIMULATIONS FOR A DC GUN BASED INJECTOR FOR PERL.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ZHOU,F.; BEN-ZVI,I.; WANG,X.J.

    2001-06-18

    The National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory (BNL) is considering an upgrade based on the Photoinjected Energy Recovering Linac (PERL). The various injector schemes for this machine are being extensively investigated at BNL. One of the possible options is photocathode DC gun. The schematic layout of a PERL DC gun based injector and its preliminary beam dynamics are presented in this paper. The transverse and longitudinal emittance of photo-electron beam were optimized for a DC field 500 kV.

  1. A gasdynamic gun driven by gaseous detonation

    NASA Astrophysics Data System (ADS)

    Li, Jinping; Chen, Hong; Zhang, Shizhong; Zhang, Xiaoyuan; Yu, Hongru

    2016-01-01

    A gasdynamic gun driven by gaseous detonation was developed to address the disadvantages of the insufficient driving capability of high-pressure gas and the constraints of gunpowder. The performance of this gasdynamic gun was investigated through experiments and numerical simulations. Much more powerful launching capability was achieved by this gun relative to a conventional high-pressure gas gun, owing to the use of the chemical energy of the driver gas. To achieve the same launching condition, the initial pressure required for this gun was an order of magnitude lower than that for a gun driven by high-pressure H2. Because of the presence of the detonation, however, a more complex internal ballistic process of this gun was observed. Acceleration of projectiles for this gun was accompanied by a series of impulse loads, in contrast with the smooth acceleration for a conventional one, which indicates that this gun should be used conditionally. The practical feasibility of this gun was verified by experiments. The experiments demonstrated the convenience of taking advantage of the techniques developed for detonation-driven shock tubes and tunnels.

  2. Guns at College.

    ERIC Educational Resources Information Center

    Miller, Matthew; Hemenway, David; Wechsler, Henry

    1999-01-01

    Surveyed undergraduate students nationwide concerning firearm possession. About 3.5% possessed working firearms. Students with guns were more likely to be male, White, or Native American; binge drink; live off-campus; and live with a spouse or significant other. Students with guns were more likely to engage in activities that put themselves and…

  3. 78 FR 66840 - Revocation of Certain Requirements Pertaining to Caps Intended for Use With Toy Guns and Toy Guns...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-07

    ... Certain Requirements Pertaining to Caps Intended for Use With Toy Guns and Toy Guns Not Intended for Use... regulations pertaining to caps intended for use with toy guns refer to obsolete equipment, but the ASTM F963... revokes the existing regulations pertaining to caps intended for use with toy guns and toy guns not...

  4. Vacuum vapor deposition gun assembly

    DOEpatents

    Zeren, Joseph D.

    1985-01-01

    A vapor deposition gun assembly includes a hollow body having a cylindrical outer surface and an end plate for holding an adjustable heat sink, a hot hollow cathode gun, two magnets for steering the plasma from the gun into a crucible on the heat sink, and a shutter for selectively covering and uncovering the crucible.

  5. Teen Suicide and Guns

    MedlinePlus

    ... Text Size Email Print Share Teen Suicide and Guns Page Content Article Body Protect Your Teenager Many ... American teenagers commit suicide every day. Does a gun in the home increase the chance of suicide? ...

  6. 75 FR 16753 - Certain Helical Spring Lock Washers From the People's Republic of China: Rescission of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-02

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-822] Certain Helical Spring Lock... opportunity to request an administrative review of the antidumping duty order on certain helical spring lock... Works Inc., the petitioner, to conduct an administrative review of Hangzhou Spring Washer Co., Ltd...

  7. Automatic targeting of plasma spray gun

    DOEpatents

    Abbatiello, Leonard A.; Neal, Richard E.

    1978-01-01

    A means for monitoring the material portion in the flame of a plasma spray gun during spraying operations is provided. A collimated detector, sensitive to certain wavelengths of light emission, is used to locate the centroid of the material with each pass of the gun. The response from the detector is then relayed to the gun controller to be used to automatically realign the gun.

  8. Hot hollow cathode gun assembly

    DOEpatents

    Zeren, J.D.

    1983-11-22

    A hot hollow cathode deposition gun assembly includes a hollow body having a cylindrical outer surface and an end plate for holding an adjustable heat sink, the hot hollow cathode gun, two magnets for steering the plasma from the gun into a crucible on the heat sink, and a shutter for selectively covering and uncovering the crucible.

  9. Are "goods for guns" good for the community? An update of a community gun buyback program.

    PubMed

    Green, Jonathan; Damle, Rachelle N; Kasper, Rebecca E; Violano, Pina; Manno, Mariann; Nazarey, Pradeep P; Aidlen, Jeremy T; Hirsh, Michael P

    2017-08-01

    Gun violence remains a leading cause of death in the United States. Community gun buyback programs provide an opportunity to dispose of extraneous firearms. The purpose of this study was to understand the demographics, motivation, child access to firearms, and household mental illness of buyback participants in hopes of improving the program's effectiveness. A 2015 Injury Free Coalition for Kids gun buyback program which collaborated with local police departments was studied. We administered a 23-item questionnaire survey to gun buyback participants assessing demographic characteristics, motivation for relinquishing firearms, child firearm accessibility, and mental illness/domestic violence history. A total of 186 individuals from Central/Western Massachusetts turned in 339 weapons. Participants received between US $25 and US $75 in gift cards dependent on what type of gun was turned in, with an average cost of $41/gun. A total of 109 (59%) participants completed the survey. Respondents were mostly white (99%), men (90%) and first-time participants in the program (85.2%). Among survey respondents, 54% turned in firearms "for safety reasons." Respondents reported no longer needing/wanting their weapons (47%) and approximately one in eight participants were concerned the firearm(s) were accessible to children. Most respondents (87%) felt the program encouraged neighborhood awareness of firearm safety. Three of every five participants reported that guns still remained in their homes; additionally, 21% where children could potentially access them and 14% with a history of mental illness/suicide/domestic violence in the home. Gun buybacks can provide a low-cost means of removing unwanted firearms from the community. Most participants felt their homes were safer after turning in the firearm(s). In homes still possessing guns, emphasis on secure gun storage should continue, increasing the safety of children and families. The results of this survey also provided new

  10. Development program on a Spindt cold-cathode electron gun

    NASA Technical Reports Server (NTRS)

    Spindt, C. A.

    1982-01-01

    A thin film field emission cathode (TFFEC) array and a cold cathode electron gun based on the emitter were developed. A microwave tube gun that uses the thin film field emission cathode as an electron source is produced. State-of-the-art cathodes were fabricated and tested. The tip-packing density of the arrays were increased thereby increasing the cathode's current density capability. The TFFEC is based on the well known field emission effect and was conceived to exploit the advantages of that phenomenon while minimizing the difficulties associated with conventional field emission structures, e.g. limited life and high voltage requirements. Field emission follows the Fowler-Nordheim equation.

  11. Development of a novel thermionic RF electron gun applied on a compact THz-FEL facility

    NASA Astrophysics Data System (ADS)

    Hu, T. N.; Pei, Y. J.; Qin, B.; Liu, K. F.; Feng, G. Y.

    2018-04-01

    The current requirements from civil and commercial applications lead to the development of compact free-electron laser (FEL)-based terahertz (THz) radiation sources. A picosecond electron gun plays an important role in an FEL-THz facility and attracts significant attention, as machine performance is very sensitive to initial conditions. A novel thermionic gun with an external cathode (EC) and two independently tunable cavities (ITCs) has been found to be a promising alternative to conventional electron sources due to its remarkable characteristics, and correspondingly an FEL injector can achieve a balance between a compact layout and high brightness benefitting from the velocity bunching properties and RF focusing effects in the EC-ITC gun. Nevertheless, the EC-ITC gun has not been extensively examined as part of the FEL injector in the past years. In this regard, to fill this gap, a development focusing on the experimental setup of an FEL injector based on an EC-ITC gun is described in detail. Before assembly, dynamic beam simulations were performed to investigate the optimal mounting position for the Linac associated with the focusing coils, and a suitable radio-frequency (RF) system was established based on a power coupling design and allocation. The testing bench proved to be fully functional through basic experiments using typical diagnostic approaches for estimating primary parameters. Associated with dynamic beam calculations, a performance evaluation for an EC-ITC gun was established while providing indirect testing results for an FEL injector.

  12. Glue Guns: Aiming for Safety

    ERIC Educational Resources Information Center

    Roy, Ken

    2010-01-01

    While glue guns are very useful, there are safety issues. Regardless of the temperature setting, glue guns can burn skin. The teacher should demonstrate and supervise the use of glue guns and have a plan should a student get burned. There should be an initial first aid protocol in place, followed by a visit to the school nurse. An accident report…

  13. 78 FR 765 - Large Residential Washers From Korea and Mexico; Revised Schedule for the Subject Investigations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-04

    ... INTERNATIONAL TRADE COMMISSION [Investigation Nos. 701-TA-488 and 731-TA-1199-1200 (Final)] Large Residential Washers From Korea and Mexico; Revised Schedule for the Subject Investigations AGENCY: United... information on this matter by contacting the Commission's TDD terminal on 202-205-1810. Persons with mobility...

  14. "Is there a gun in the home?" Assessing the risks of gun ownership in older adults.

    PubMed

    Pinholt, Ellen M; Mitchell, Joshua D; Butler, Jane H; Kumar, Harjinder

    2014-06-01

    An important ethical and safety concern that geriatricians, primary care providers, and home health professionals need to address is gun ownership by elderly adults. Those aged 65 and older now have the highest rate of gun ownership in America, and they also have a high prevalence of depression and suicide. Dementia can add additional layers of risk. Even older gun owners who are otherwise intellectually intact may benefit from information about gun safety with the increasing numbers of children being cared for by grandparents. Health professionals should ask patients, "Is there a gun in the home?" in the clinic and during home visits. Healthcare professionals must have knowledge and skills to address safe gun ownership in elderly adults. The 5 L's (Locked, Loaded, Little children, feeling Low, Learned owner) will assist professionals in addressing all aspects of safe ownership. © 2014, Copyright the Authors Journal compilation © 2014, The American Geriatrics Society.

  15. THz and Sub-THz Capabilities of a Table-Top Radiation Source Driven by an RF Thermionic Electron Gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smirnov, Alexei V.; Agustsson, R.; Boucher, S.

    Design features and experimental results are presented for a sub-mm wave source [1] based on APS RF thermionic electron gun. The setup includes compact alpha-magnet, quadrupoles, sub-mm-wave radiators, and THz optics. The sub-THz radiator is a planar, oversized structure with gratings. Source upgrade for generation frequencies above 1 THz is discussed. The THz radiator will use a short-period undulator having 1 T field amplitude, ~20 cm length, and integrated with a low-loss oversized waveguide. Both radiators are integrated with a miniature horn antenna and a small ~90°-degree in-vacuum bending magnet. The electron beamline is designed to operate different modes includingmore » conversion to a flat beam interacting efficiently with the radiator. The source can be used for cancer diagnostics, surface defectoscopy, and non-destructive testing. Sub-THz experiment demonstrated a good potential of a robust, table-top system for generation of a narrow bandwidth THz radiation. This setup can be considered as a prototype of a compact, laser-free, flexible source capable of generation of long trains of Sub-THz and THz pulses with repetition rates not available with laser-driven sources.« less

  16. Firearm retailers' willingness to participate in an illegal gun purchase.

    PubMed

    Wintemute, Garen

    2010-09-01

    Firearm-related violence is a significant public health and public safety problem for cities in the USA, and licensed firearm retailers are an important source of the guns used in that violence. Using a scripted telephone interview, we screened a sample of licensed retailers in California to assess their willingness to participate in the surrogate or "straw" purchase of a handgun; such purchases are illegal under federal law. Of 149 retailers who provided a response, 30 (20.1%) agreed to participate. In multivariate analysis, pawnbrokers were more likely to agree than were gun dealers (odds ratio 6.58, 95% confidence interval 1.99-21.71). Sales of handguns that were later subjected to ownership tracing (a proxy measure for a gun's use in crime) were not more frequent among retailers who agreed to participate than among others, and other findings were unexpected as well.

  17. Gun muzzle blast and flash

    NASA Astrophysics Data System (ADS)

    Klingenberg, Guenter; Heimerl, Joseph M.

    A repository of fundamental experimental and analytical data concerning the complex phenomena associated with gun-muzzle blast and flash effects is presented, proceeding from gun muzzle signatures to modern gun-propulsion concepts, interior and transitional ballistics, and characterizations of blast-wave research and muzzle flash. Data are presented in support of a novel hypothesis which explains the ignition of secondary flash and elucidates the means for its suppression. Both chemical and mechanical (often competing) methods of flash suppression are treated. The historical work of Kesslau and Ladenburg is noted, together with French, British, Japanese and American research efforts and current techniques of experimental characterization for gun muzzle phenomena.

  18. A Robust High Current Density Electron Gun

    NASA Astrophysics Data System (ADS)

    Mako, F.; Peter, W.; Shiloh, J.; Len, L. K.

    1996-11-01

    Proof-of-principle experiments are proposed to validate a new concept for a robust, high-current density Pierce electron gun (RPG) for use in klystrons and high brightness electron sources for accelerators. This rugged, long-life electron gun avoids the difficulties associated with plasma cathodes, thermionic emitters, and field emission cathodes. The RPG concept employs the emission of secondary electrons in a transmission mode as opposed to the conventional mode of reflection, i.e., electrons exit from the back face of a thin negative electron affinity (NEA) material, and in the same direction as the incident beam. Current amplification through one stage of a NEA material could be over 50 times. The amplification is accomplished in one or more stages consisting of one primary emitter and one or more secondary emitters. The primary emitter is a low current density robust emitter (e.g., thoriated tungsten). The secondary emitters are thin NEA electrodes which emit secondary electrons in the same direction as the incident beam. Specific application is targeted for a klystron gun to be used by SLAC with a cold cathode at 30-40 amps/cm^2 output from the secondary emission stage, a ~2 μs pulse length, and ~200 pulses/second.

  19. Plasma-anode electron gun

    NASA Astrophysics Data System (ADS)

    Santoru, Joseph; Schumacher, Robert W.; Gregoire, Daniel J.

    1994-11-01

    The plasma-anode electron gun (PAG) is an electron source in which the thermionic cathode is replaced with a cold, secondary-electron-emitting electrode. Electron emission is stimulated by bombarding the cathode with high-energy ions. Ions are injected into the high-voltage gap through a gridded structure from a plasma source (gas pressure less than or equal to 50 mTorr) that is embedded in the anode electrode. The gridded structure serves as both a cathode for the plasma discharge and as an anode for the PAG. The beam current is modulated at near ground potential by modulating the plasma source, eliminating the need for a high-voltage modulator system. During laboratory tests, the PAG has demonstrated square-wave, 17-microsecond-long beam pulses at 100 kV and 10 A, and it has operated stably at 70 kV and 2.5 A for 210 microsecond pulse lengths without gap closure.

  20. Gas gun dynamics

    NASA Astrophysics Data System (ADS)

    Denny, Mark

    2013-09-01

    The mechanics and thermodynamics of one- and two-stage gas guns are developed. Very high projectile muzzle speed can be obtained by the two-stage version. The physics of simple gas guns, such as air rifles, is accessible to undergraduates and the same level of presentation is used here to understand more complex designs. Numerical solutions to the equations of motion are shown, along with insightful analytic approximations.

  1. Alignment Fixtures For Vacuum-Plasma-Spray Gun

    NASA Technical Reports Server (NTRS)

    Woodford, William H.; Mckechnie, Timothy N.; Power, Christopher A.; Daniel, Ronald L., Jr.

    1993-01-01

    Fixtures for alignment of vacuum-plasma-spray guns built. Each fixture designed to fit specific gun and holds small, battery-powered laser on centerline of gun. Laser beam projects small red dot where centerline intersects surface of workpiece to be sprayed. After laser beam positioned on surface of workpiece, fixture removed from gun and spraying proceeds.

  2. Cost Estimate for Gun Liner Emplacement

    DTIC Science & Technology

    2011-08-01

    material. The M2 machine gun has a Stellite 21 liner that covers only about one-half of the barrel length. It has been successful in reducing the...Michael R. M2 Machine Gun Barrel Wear with SLAP Ammunition. To be published in Journal of Materials and Manufacturing Processes. 8. Miller, Mark D...case in point is the use of a Stellite 21 liner in the M2 0.50-cal machine gun . However, liners have generally been difficult to place into gun tubes

  3. Advances in light-gas gun technology

    NASA Technical Reports Server (NTRS)

    Cowan, P. L.; Murphy, J. R.

    1968-01-01

    Constant-area accelerator used with light-gas guns increases the velocity of accelerating projectiles. A disposable accelerator on the muzzle of the gun uses the energy and momentum of a primary projectile, launched by the gun, to achieve high velocities of a light secondary projectile accelerated from rest in the accelerator.

  4. Superconducting 112 MHz QWR electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belomestnykh, S.; Ben-Zvi, I.; Boulware, C.H.

    Brookhaven National Laboratory and Niowave, Inc. have designed and fabricated a superconducting 112 MHz quarter-wave resonator (QWR) electron gun. The first cold test of the QWR cryomodule has been completed at Niowave. The paper describes the cryomodule design, presents the cold test results, and outline plans to upgrade the cryomodule. Future experiments include studies of different photocathodes and use for the coherent electron cooling proof-of-principle experiment. Two cathode stalk options, one for multi-alkali photocathodes and the other one for a diamond-amplified photocathode, are discussed. A quarter-wave resonator concept of superconducting RF (SRF) electron gun was proposed at BNL for electronmore » cooling hadron beams in RHIC. QWRs can be made sufficiently compact even at low RF frequencies (long wavelengths). The long wavelength allows to produce long electron bunches, thus minimizing space charge effects and enabling high bunch charge. Also, such guns should be suitable for experiments requiring high average current electron beams. A 112 MHz QWR gun was designed, fabricated, and cold-tested in collaboration between BNL and Niowave. This is the lowest frequency SRF gun ever tested successfully. In this paper we describe the gun design and fabrication, present the cold test results, and outline our plans. This gun will also serve as a prototype for a future SRF gun to be used for coherent electron cooling of hadrons in eRHIC.« less

  5. Association Between Substance Use and Gun-Related Behaviors

    PubMed Central

    Chen, Danhong; Wu, Li-Tzy

    2016-01-01

    Gun-related violence is a public health concern. This study synthesizes findings on associations between substance use and gun-related behaviors. Searches through PubMed, Embase, and PsycINFO located 66 studies published in English between 1992 and 2014. Most studies found a significant bivariate association between substance use and increased odds of gun-related behaviors. However, their association after adjustment was mixed, which could be attributed to a number of factors such as variations in definitions of substance use and gun activity, study design, sample demographics, and the specific covariates considered. Fewer studies identified a significant association between substance use and gun access/possession than other gun activities. The significant association between nonsubstance covariates (e.g., demographic covariates and other behavioral risk factors) and gun-related behaviors might have moderated the association between substance use and gun activities. Particularly, the strength of association between substance use and gun activities tended to reduce appreciably or to become nonsignificant after adjustment for mental disorders. Some studies indicated a positive association between the frequency of substance use and the odds of engaging in gun-related behaviors. Overall, the results suggest a need to consider substance use in research and prevention programs for gun-related violence. PMID:26769722

  6. Not an 'iron pipeline', but many capillaries: regulating passive transactions in Los Angeles' secondary, illegal gun market.

    PubMed

    Chesnut, Kelsie Y; Barragan, Melissa; Gravel, Jason; Pifer, Natalie A; Reiter, Keramet; Sherman, Nicole; Tita, George E

    2017-08-01

    California has strict firearm-related laws and is exceptional in its regulation of firearms retailers. Though evidence suggests that these laws can reduce illegal access to guns, high levels of gun violence persist in Los Angeles (LA), California. This research seeks to describe the sources of guns accessed by active offenders in LA, California and reports offenders' motivations for obtaining guns. Los Angeles County Jail (LACJ) system (four facilities). Random sampling from a screened pool of eligible participants was used to conduct qualitative semistructured interviews with 140 incarcerated gun offenders in one of four (LACJ) facilities. Researchers collected data on firearm acquisition, experiences related to gun violence, and other topics, using a validated survey instrument. Grounded theory guided the collection and analysis of data. Respondents reported possession of 77 specific guns (79.2% handguns) collectively. Social networks facilitate access to illegal guns; the majority of interviewees acquired their illegal guns through a social connection (85.7%) versus an outside broker/unregulated retailer (8.5%). Most guns were obtained through illegal purchase (n=51) or gift (n=15). A quarter of gun purchasers report engaging in a passive transaction, or one initiated by another party. Passive gun buyers were motivated by concerns for personal safety and/or economic opportunity. In LA's illegal gun market, where existing social relationships facilitate access to guns across a diffuse network, individuals, influenced by both fear and economic opportunity, have frequent opportunities to illegally possess firearms through passive transactions. Gun policies should better target and minimise these transactions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  7. Nail-Gun Injuries to the Hand

    PubMed Central

    Pierpont, Yvonne N.; Pappas-Politis, Effie; Naidu, Deepak K.; Salas, R. Emerick; Johnson, Erika L.; Payne, Wyatt G.

    2008-01-01

    Background: The nail gun is a commonly utilized tool in carpentry and construction. When used properly with appropriate safety precautions, it can facilitate production and boost efficiency; however, this powerful tool also has the potential to cause serious injury. The most common site of nail-gun injuries in both industrial and nonoccupational settings is the hand. Materials and Methods: We report on two patients with nail-gun injuries to the hand. A review of the literature and discussion of clinical evaluation and treatment of nail-gun injuries to the hand are presented. Results: Two patients present with soft tissue injuries to the hand with the nail embedded and intact at the injury site. Operative removal of the nail and wound care resulted in successful treatment in both cases. Nail-gun injuries to the hand vary in severity on the basis of the extent of structural damage. Treatment is based on the severity of injury and the presence and location of barbs on the penetrating nail. Conclusion: Healthcare providers must understand and educate patients on the prevention mechanics of nail-gun injuries. Nail-gun injuries to the hand necessitate appropriate evaluation techniques, understanding of surgical management versus nonsurgical management, and awareness of potential pitfalls in treatment. PMID:19079574

  8. Design and development of line type modulators for high impedance electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dixit, Kavita P.; Tillu, Abhijit; Chavan, Ramchandra

    Conventional line type modulators are routinely used for powering pulsed power microwave devices such as magnetrons and klystrons used for radar, medical and scientific applications. The load impedance (operating point) is fairly well defined in these cases, and makes the design of the discharging circuit of the modulator straight forward. This paper describes the Line type modulators that have been developed and being routinely used for powering the Triode Electron Gun of industrial electron linacs. The beam parameters of such guns are user defined and the pulse current varies from few mA to 800mA (typ). The beam energies requirement variesmore » from 40 keV to 80 keV. Hence the impedance offered by the electron gun to the power source (modulator) is not well defined. The load capacitance which is inclusive of the various stray capacitances along with the intrinsic gun capacitance is ∼ 200-400 pF. This capacitance, which depends on the configuration, shunts the load and makes the effective load highly capacitive with the resistive part varying over a wide range. The paper describes the design and development of conventional line type modulators for powering Electron gun load of the type described above. (author)« less

  9. Interpreting the empirical evidence on illegal gun market dynamics.

    PubMed

    Braga, Anthony A; Wintemute, Garen J; Pierce, Glenn L; Cook, Philip J; Ridgeway, Greg

    2012-10-01

    Thousands of Americans are killed by gunfire each year, and hundreds of thousands more are injured or threatened with guns in robberies and assaults. The burden of gun violence in urban areas is particularly high. Critics suggest that the results of firearm trace data and gun trafficking investigation studies cannot be used to understand the illegal supply of guns to criminals and, therefore, that regulatory and enforcement efforts designed to disrupt illegal firearms markets are futile in addressing criminal access to firearms. In this paper, we present new data to address three key arguments used by skeptics to undermine research on illegal gun market dynamics. We find that criminals rely upon a diverse set of illegal diversion pathways to acquire guns, gun traffickers usually divert small numbers of guns, newer guns are diverted through close-to-retail diversions from legal firearms commerce, and that a diverse set of gun trafficking indicators are needed to identify and shut down gun trafficking pathways.

  10. News media framing of serious mental illness and gun violence in the United States, 1997-2012.

    PubMed

    McGinty, Emma E; Webster, Daniel W; Jarlenski, Marian; Barry, Colleen L

    2014-03-01

    Recent mass shootings by persons seemingly afflicted with serious mental illness (SMI) have received extensive news media coverage and prompted national dialogue about the causes of, and policy responses to, mass shootings. News media framing of SMI as a cause of gun violence may influence public attitudes about persons with SMI and support for gun violence prevention proposals. We analyzed the content of a 25% random sample of news stories on SMI and gun violence published in 14 national and regional news sources from 1997 to 2012. Across the study period, most news coverage occurred in the wake of mass shootings, and "dangerous people" with SMI were more likely than "dangerous weapons" to be mentioned as a cause of gun violence.

  11. News Media Framing of Serious Mental Illness and Gun Violence in the United States, 1997-2012

    PubMed Central

    Webster, Daniel W.; Jarlenski, Marian; Barry, Colleen L.

    2014-01-01

    Recent mass shootings by persons seemingly afflicted with serious mental illness (SMI) have received extensive news media coverage and prompted national dialogue about the causes of, and policy responses to, mass shootings. News media framing of SMI as a cause of gun violence may influence public attitudes about persons with SMI and support for gun violence prevention proposals. We analyzed the content of a 25% random sample of news stories on SMI and gun violence published in 14 national and regional news sources from 1997 to 2012. Across the study period, most news coverage occurred in the wake of mass shootings, and “dangerous people” with SMI were more likely than “dangerous weapons” to be mentioned as a cause of gun violence. PMID:24432874

  12. Remotely controlled spray gun

    NASA Technical Reports Server (NTRS)

    Cunningham, William C. (Inventor)

    1987-01-01

    A remotely controlled spray gun is described in which a nozzle and orifice plate are held in precise axial alignment by an alignment member, which in turn is held in alignment with the general outlet of the spray gun by insert. By this arrangement, the precise repeatability of spray patterns is insured.

  13. Sanitation in self-service automatic washers.

    PubMed Central

    Buford, L E; Pickett, M S; Hartman, P A

    1977-01-01

    The potential for microbial transfer in self-service laundry washing machines was investigated by obtaining swab samples from the interior surfaces of commercial machines and wash water samples before and after disinfectant treatment. Three disinfectants (chlorine, a quaternary ammonium product, and a phenolic disinfectant) were used. Four self-service laundry facilities were sampled, with 10 replications of the procedure for each treatment at each location. Although washers were set on a warmwater setting, the wash water temperatures ranged from 24 to 51 degrees C. The quaternary ammonium product seemed most effective, averaging a 97% microbial kill; chlorine was the second most effective, with a 58% kill, and the phenolic disinfectant was least effective, with only a 25% kill. The efficacies of the chlorine and phenolic disinfectants were reduced at low water temperatures commonly experienced in self-service laundries. Interfamily cross-contamination in self-service facilities is a potential public health problem, which is aggravated by environmental conditions, such as water temperature and the practices of the previous users of the equipment. Procedural changes in laundering are recommended, including the use of a disinfectant to maintain adequate levels of sanitation. PMID:13714

  14. Beam Dynamics Simulation of Photocathode RF Electron Gun at the PBP-CMU Linac Laboratory

    NASA Astrophysics Data System (ADS)

    Buakor, K.; Rimjaem, S.

    2017-09-01

    Photocathode radio-frequency (RF) electron guns are widely used at many particle accelerator laboratories due to high quality of produced electron beams. By using a short-pulse laser to induce the photoemission process, the electrons are emitted with low energy spread. Moreover, the photocathode RF guns are not suffered from the electron back bombardment effect, which can cause the limited electron current and accelerated energy. In this research, we aim to develop the photocathode RF gun for the linac-based THz radiation source. Its design is based on the existing gun at the PBP-CMU Linac Laboratory. The gun consists of a one and a half cell S-band standing-wave RF cavities with a maximum electric field of about 60 MV/m at the centre of the full cell. We study the beam dynamics of electrons traveling through the electromagnetic field inside the RF gun by using the particle tracking program ASTRA. The laser properties i.e. transverse size and injecting phase are optimized to obtain low transverse emittance. In addition, the solenoid magnet is applied for beam focusing and emittance compensation. The proper solenoid magnetic field is then investigated to find the optimum value for proper emittance conservation condition.

  15. Community gun safety in Central Pennsylvania.

    PubMed

    Wargo, Christina; Erdman, Deborah A; Smith, Jill Gray; Widom, Kenneth; Reardon, Judith

    2013-01-01

    Firearm-related injuries are a public health issue in the United States. In rural Pennsylvania, it is a familiar way of life to have a gun or guns in the home. Safety behaviors along with gun storage in the home, specifically where there are young children (aged 6 years and younger), are a concern for this level I regional resource center in rural Pennsylvania. Head Start families were surveyed regarding gun safety habits before and after safety educational activities. A noteworthy number of families reported changing behaviors regarding better safety habits for storing and use of firearms in the home postsurvey.

  16. Conceptual Design for CLIC Gun Pulser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tang, Tao

    The Compact Linear Collider (CLIC) is a proposed future electron-positron collider, designed to perform collisions at energies from 0.5 to 5 TeV, with a nominal design optimized for 3 TeV (Dannheim, 2012). The Drive Beam Accelerator consists of a thermionic DC gun, bunching section and an accelerating section. The thermionic gun needs deliver a long (~143us) pulse of current into the buncher. A pulser is needed to drive grid of the gun to generate a stable current output. This report explores the requirements of the gun pulser and potential solutions to regulate grid current.

  17. 77 FR 46401 - Large Residential Washers From Mexico: Preliminary Determination of Sales at Less Than Fair Value...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-03

    ... events have occurred.\\1\\ \\1\\ See Large Residential Washers From the Republic of Korea and Mexico... if, in the event of an affirmative preliminary determination, a request for such postponement is made... the event of a negative preliminary determination, a request for such postponement is made by the...

  18. Impurities, temperature, and density in a miniature electrostatic plasma and current source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Den Hartog, D.J.; Craig, D.J.; Fiksel, G.

    1996-10-01

    We have spectroscopically investigated the Sterling Scientific miniature electrostatic plasma source-a plasma gun. This gun is a clean source of high density (10{sup 19} - 10{sup 20} m{sup -3}), low temperature (5 - 15 eV) plasma. A key result of our investigation is that molybdenum from the gun electrodes is largely trapped in the internal gun discharge; only a small amount escapes in the plasma flowing out of the gun. In addition, the gun plasma parameters actually improve (even lower impurity contamination and higher ion temperature) when up to 1 kA of electron current is extracted from the gun viamore » the application of an external bias. This improvement occurs because the internal gun anode no longer acts as the current return for the internal gun discharge. The gun plasma is a virtual plasma electrode capable of sourcing an electron emission current density of 1 kA/cm{sup 2}. The high emission current, small size (3 - 4 cm diameter), and low impurity generation make this gun attractive for a variety of fusion and plasma technology applications.« less

  19. Correlates of Gun Involvement and Aggressiveness among Adolescents.

    ERIC Educational Resources Information Center

    Ding, Cody S.; Nelsen, Edward A.; Lassonde, Cynthia T.

    2002-01-01

    Investigated adolescents' aggressiveness in relation to their experiences, beliefs, and attitudes concerning gun use, also noting family composition, relationships with parents, and emotionality as correlates of gun involvement and aggression. Student surveys indicated links between gun ownership and recreational use, beliefs about gun use, and…

  20. Gun Violence, mental health, and Connecticut physicians.

    PubMed

    Dodds, Peter R; Anderson, Caitlyn O; Dodds, Jon H

    2014-01-01

    While there is a public perception that gun violence is associated with mental illness we present evidence that it is a complex public health problem which defies simple characterizations and solutions. Only a small percentage of individuals with mental illness are at risk for extreme violence and they account for only a small percentage of gun-related homicides. Individuals who are at risk for gun violence are difficult to identify and successfully treat. The incidence, and perhaps the demographics, of gun violence vary substantially from state to state. We make a case for Connecticut physicians to study gun violence at the state level. We recommend that Connecticut physicians promote and expand upon the American Academy of Pediatrics' recommendation for creating a "safe home environment. "We suggest that guns be secured in all homes in which there are children. In addition we suggest that guns be voluntarily removed from homes in which there are individuals with a history of violence, threats of violence, depression, drug and/or alcohol abuse, and individuals with major mental illnesses who are not cooperating with therapy.

  1. Femtosecond-laser-driven photoelectron-gun for time-resolved cathodoluminescence measurement of GaN.

    PubMed

    Onuma, T; Kagamitani, Y; Hazu, K; Ishiguro, T; Fukuda, T; Chichibu, S F

    2012-04-01

    A rear-excitation femtosecond-laser-driven photoelectron gun (PE-gun) is developed for measuring time-resolved cathodoluminescence (TRCL) spectrum of wide bandgap materials and structures such as semiconductors and phosphors. The maximum quantum efficiency of a 20-nm-thick Au photocathode excited using a frequency-tripled Al(2)O(3):Ti laser under a rear-excitation configuration is 3.6×10(-6), which is a reasonable value for a PE-gun. When the distance between the front edge of the PE-gun and the observation point is 10 mm, the narrowest electron-beam (e-beam) diameter is 19 μm, which corresponds to one tenth of the laser-beam diameter and is comparable to the initial e-beam diameter of a typical W hair-pin filament of thermionic electron-gun. From the results of TRCL measurements on the freestanding GaN grown by the ammonothermal method and a GaN homoepitaxial film grown by metalorganic vapor phase epitaxy, overall response time for the present TRCL system is estimated to be 8 ps. The value is the same as that of time-resolved photoluminescence measurement using the same excitation laser pulses, meaning that the time-resolution is simply limited by the streak-camera, not by the PE-gun performance. The result of numerical simulation on the temporal e-beam broadening caused by the space-charge-effect suggests that the present PE-gun can be used as a pulsed e-beam source for spatio-time-resolved cathodoluminescence, when equipped in a scanning electron microscope. © 2012 American Institute of Physics

  2. Femtosecond-laser-driven photoelectron-gun for time-resolved cathodoluminescence measurement of GaN

    NASA Astrophysics Data System (ADS)

    Onuma, T.; Kagamitani, Y.; Hazu, K.; Ishiguro, T.; Fukuda, T.; Chichibu, S. F.

    2012-04-01

    A rear-excitation femtosecond-laser-driven photoelectron gun (PE-gun) is developed for measuring time-resolved cathodoluminescence (TRCL) spectrum of wide bandgap materials and structures such as semiconductors and phosphors. The maximum quantum efficiency of a 20-nm-thick Au photocathode excited using a frequency-tripled Al2O3:Ti laser under a rear-excitation configuration is 3.6×10-6, which is a reasonable value for a PE-gun. When the distance between the front edge of the PE-gun and the observation point is 10 mm, the narrowest electron-beam (e-beam) diameter is 19 μm, which corresponds to one tenth of the laser-beam diameter and is comparable to the initial e-beam diameter of a typical W hair-pin filament of thermionic electron-gun. From the results of TRCL measurements on the freestanding GaN grown by the ammonothermal method and a GaN homoepitaxial film grown by metalorganic vapor phase epitaxy, overall response time for the present TRCL system is estimated to be 8 ps. The value is the same as that of time-resolved photoluminescence measurement using the same excitation laser pulses, meaning that the time-resolution is simply limited by the streak-camera, not by the PE-gun performance. The result of numerical simulation on the temporal e-beam broadening caused by the space-charge-effect suggests that the present PE-gun can be used as a pulsed e-beam source for spatio-time-resolved cathodoluminescence, when equipped in a scanning electron microscope.

  3. Association Between Substance Use and Gun-Related Behaviors.

    PubMed

    Chen, Danhong; Wu, Li-Tzy

    2016-01-01

    Gun-related violence is a public health concern. This study synthesizes findings on associations between substance use and gun-related behaviors. Searches through PubMed, Embase, and PsycINFO located 66 studies published in English between 1992 and 2014. Most studies found a significant bivariate association between substance use and increased odds of gun-related behaviors. However, their association after adjustment was mixed, which could be attributed to a number of factors such as variations in definitions of substance use and gun activity, study design, sample demographics, and the specific covariates considered. Fewer studies identified a significant association between substance use and gun access/possession than other gun activities. The significant association between nonsubstance covariates (e.g., demographic covariates and other behavioral risk factors) and gun-related behaviors might have moderated the association between substance use and gun activities. Particularly, the strength of association between substance use and gun activities tended to reduce appreciably or to become nonsignificant after adjustment for mental disorders. Some studies indicated a positive association between the frequency of substance use and the odds of engaging in gun-related behaviors. Overall, the results suggest a need to consider substance use in research and prevention programs for gun-related violence. © The Author 2016. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. Is There a Gun in the House? Gun Safety in the Home.

    ERIC Educational Resources Information Center

    Keller, Rosanne

    Written in a conversational style with illustrations, this booklet from a series of home literacy readers is directed at the Alaskan environment where guns are a way of life, used for food and defense from animals. But more than 10% of the 1,300 U.S. deaths from gun accidents occur in Alaska, and more than 70%, at home. Nearly half the victims are…

  5. A novel electron gun for inline MRI-linac configurations.

    PubMed

    Constantin, Dragoş E; Holloway, Lois; Keall, Paul J; Fahrig, Rebecca

    2014-02-01

    This work introduces a new electron gun geometry capable of robust functioning in the presence of a high strength external magnetic field for axisymmetric magnetic resonance imaging (MRI)-linac configurations. This allows an inline MRI-linac to operate without the need to isolate the linear accelerator (linac) using a magnetic shield. This MRI-linac integration approach not only leaves the magnet homogeneity unchanged but also provides the linac flexibility to move along the magnet axis of symmetry if the source to target distance needs to be adjusted. Simple electron gun geometry modifications of a Varian 600 C electron gun are considered and solved in the presence of an external magnetic field in order to determine a set of design principles for the new geometry. Based on these results, a new gun geometry is proposed and optimized in the fringe field of a 0.5 T open bore MRI magnet (GE Signa SP). A computer model for the 6 MeV Varian 600 C linac is used to determine the capture efficiency of the new electron gun-linac system in the presence of the fringe field of the same MRI scanner. The behavior of the new electron gun plus the linac system is also studied in the fringe fields of two other magnets, a 1.0 T prototype open bore magnet and a 1.5 T GE Conquest scanner. Simple geometrical modifications of the original electron gun geometry do not provide feasible solutions. However, these tests show that a smaller transverse cathode diameter with a flat surface and a slightly larger anode diameter could alleviate the current loss due to beam interactions with the anode in the presence of magnetic fields. Based on these findings, an initial geometry resembling a parallel plate capacitor with a hole in the anode is proposed. The optimization procedure finds a cathode-anode distance of 5 mm, a focusing electrode angle of 5°, and an anode drift tube length of 17.1 mm. Also, the linac can be displaced with ± 15 cm along the axis of the 0.5 T magnet without capture

  6. A novel electron gun for inline MRI-linac configurations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Constantin, Dragoş E., E-mail: dragos.constantin@varian.com; Fahrig, Rebecca; Holloway, Lois

    2014-02-15

    Purpose: This work introduces a new electron gun geometry capable of robust functioning in the presence of a high strength external magnetic field for axisymmetric magnetic resonance imaging (MRI)-linac configurations. This allows an inline MRI-linac to operate without the need to isolate the linear accelerator (linac) using a magnetic shield. This MRI-linac integration approach not only leaves the magnet homogeneity unchanged but also provides the linac flexibility to move along the magnet axis of symmetry if the source to target distance needs to be adjusted. Methods: Simple electron gun geometry modifications of a Varian 600C electron gun are considered andmore » solved in the presence of an external magnetic field in order to determine a set of design principles for the new geometry. Based on these results, a new gun geometry is proposed and optimized in the fringe field of a 0.5 T open bore MRI magnet (GE Signa SP). A computer model for the 6 MeV Varian 600C linac is used to determine the capture efficiency of the new electron gun-linac system in the presence of the fringe field of the same MRI scanner. The behavior of the new electron gun plus the linac system is also studied in the fringe fields of two other magnets, a 1.0 T prototype open bore magnet and a 1.5 T GE Conquest scanner. Results: Simple geometrical modifications of the original electron gun geometry do not provide feasible solutions. However, these tests show that a smaller transverse cathode diameter with a flat surface and a slightly larger anode diameter could alleviate the current loss due to beam interactions with the anode in the presence of magnetic fields. Based on these findings, an initial geometry resembling a parallel plate capacitor with a hole in the anode is proposed. The optimization procedure finds a cathode-anode distance of 5 mm, a focusing electrode angle of 5°, and an anode drift tube length of 17.1 mm. Also, the linac can be displaced with ±15 cm along the axis of the 0

  7. A novel electron gun for inline MRI-linac configurations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Constantin, Dragoş E., E-mail: dragos.constantin@varian.com; Fahrig, Rebecca; Holloway, Lois

    Purpose: This work introduces a new electron gun geometry capable of robust functioning in the presence of a high strength external magnetic field for axisymmetric magnetic resonance imaging (MRI)-linac configurations. This allows an inline MRI-linac to operate without the need to isolate the linear accelerator (linac) using a magnetic shield. This MRI-linac integration approach not only leaves the magnet homogeneity unchanged but also provides the linac flexibility to move along the magnet axis of symmetry if the source to target distance needs to be adjusted. Methods: Simple electron gun geometry modifications of a Varian 600C electron gun are considered andmore » solved in the presence of an external magnetic field in order to determine a set of design principles for the new geometry. Based on these results, a new gun geometry is proposed and optimized in the fringe field of a 0.5 T open bore MRI magnet (GE Signa SP). A computer model for the 6 MeV Varian 600C linac is used to determine the capture efficiency of the new electron gun-linac system in the presence of the fringe field of the same MRI scanner. The behavior of the new electron gun plus the linac system is also studied in the fringe fields of two other magnets, a 1.0 T prototype open bore magnet and a 1.5 T GE Conquest scanner. Results: Simple geometrical modifications of the original electron gun geometry do not provide feasible solutions. However, these tests show that a smaller transverse cathode diameter with a flat surface and a slightly larger anode diameter could alleviate the current loss due to beam interactions with the anode in the presence of magnetic fields. Based on these findings, an initial geometry resembling a parallel plate capacitor with a hole in the anode is proposed. The optimization procedure finds a cathode-anode distance of 5 mm, a focusing electrode angle of 5°, and an anode drift tube length of 17.1 mm. Also, the linac can be displaced with ±15 cm along the axis of the 0

  8. Brief use of a specific gun in a violent game does not affect attitudes towards that gun

    PubMed Central

    Engelhardt, Christopher R.; Bartholow, Bruce D.

    2016-01-01

    Although much attention has been paid to the question of whether violent video games increase aggressive behaviour, little attention has been paid to how such games might encourage antecedents of gun violence. In this study, we examined how product placement, the attractive in-game presentation of certain real-world firearm brands, might encourage gun ownership, a necessary antecedent of gun violence. We sought to study how the virtual portrayal of a real-world firearm (the Bushmaster AR-15) could influence players' attitudes towards the AR-15 specifically and gun ownership in general. College undergraduates (N = 176) played one of four modified video games in a 2 (gun: AR-15 or science-fiction control) × 2 (gun power: strong or weak) between-subjects design. Despite collecting many outcomes and examining many potential covariates and moderators, experimental assignment did little to influence outcomes of product evaluations or purchasing intentions with regard to the AR-15. Attitudes towards public policy and estimation of gun safety were also not influenced by experimental condition, although these might have been better tested by comparison against a no-violence control condition. By contrast, gender and political party had dramatic associations with all outcomes. We conclude that, if product placement shapes attitudes towards firearms, such effects will need to be studied with stronger manipulations or more sensitive measures. PMID:28018611

  9. Brief use of a specific gun in a violent game does not affect attitudes towards that gun.

    PubMed

    Hilgard, Joseph; Engelhardt, Christopher R; Bartholow, Bruce D

    2016-11-01

    Although much attention has been paid to the question of whether violent video games increase aggressive behaviour, little attention has been paid to how such games might encourage antecedents of gun violence. In this study, we examined how product placement, the attractive in-game presentation of certain real-world firearm brands, might encourage gun ownership, a necessary antecedent of gun violence. We sought to study how the virtual portrayal of a real-world firearm (the Bushmaster AR-15) could influence players' attitudes towards the AR-15 specifically and gun ownership in general. College undergraduates ( N  = 176) played one of four modified video games in a 2 (gun: AR-15 or science-fiction control) × 2 (gun power: strong or weak) between-subjects design. Despite collecting many outcomes and examining many potential covariates and moderators, experimental assignment did little to influence outcomes of product evaluations or purchasing intentions with regard to the AR-15. Attitudes towards public policy and estimation of gun safety were also not influenced by experimental condition, although these might have been better tested by comparison against a no-violence control condition. By contrast, gender and political party had dramatic associations with all outcomes. We conclude that, if product placement shapes attitudes towards firearms, such effects will need to be studied with stronger manipulations or more sensitive measures.

  10. Nail gun injuries among construction workers.

    PubMed

    Dement, John M; Lipscomb, Hester; Li, Leiming; Epling, Carol; Desai, Tejas

    2003-05-01

    Pneumatic nail guns greatly increase worker productivity and are extensively used in wood frame building construction, with especially high use in residential construction. One surveillance report of nail gun injuries in Washington State has been published; however, other literature consists largely of case reports and case series in trauma journals. The major objective of the current study was to investigate the occurrence of nail gun-associated injuries among construction workers and to identify preventable work-related factors associated with these injuries. Nail gun-related injuries occurring among a cohort of 13,347 carpenters in Ohio who worked union hours during the time period January 1, 1994, until September 30, 1997, were identified by matching the cohort with workers' compensation claims made to the Ohio Bureau of Workers' Compensation. We also analyzed workers' compensation claims for North Carolina Home Builders Association members for the period July 1996-November 1999 to identify nail gun-related injuries. Analyses included stratified analyses of claims by nature and body part injured, calculation of nail gun injury rates, and analyses of free text descriptions of injuries. Overall, nail gun injuries were responsible for 3.9 percent of workers' compensation claims with 8.3 percent to 25.5 percent of claims involving paid lost work time. The overall rate of nail gun injuries (cases per 200,000 work hours) was 0.33 in North Carolina and 0.26 in Ohio, reflecting the greater concentration of wood frame construction workers in the North Carolina population studied. Higher rates of injury were observed for carpenters in North Carolina and among residential carpenters in Ohio. The predominant body part injured was the hands/fingers, with 80 to 89 percent of injuries being nail punctures. Analyses of free text information for puncture injuries found approximately 70 percent of injuries to occur during the framing/sheathing stage of construction. Our data

  11. GUN4-Porphyrin Complexes Bind the ChlH/GUN5 Subunit of Mg-Chelatase and Promote Chlorophyll Biosynthesis in Arabidopsis[W

    PubMed Central

    Adhikari, Neil D.; Froehlich, John E.; Strand, Deserah D.; Buck, Stephanie M.; Kramer, David M.; Larkin, Robert M.

    2011-01-01

    The GENOMES UNCOUPLED4 (GUN4) protein stimulates chlorophyll biosynthesis by activating Mg-chelatase, the enzyme that commits protoporphyrin IX to chlorophyll biosynthesis. This stimulation depends on GUN4 binding the ChlH subunit of Mg-chelatase and the porphyrin substrate and product of Mg-chelatase. After binding porphyrins, GUN4 associates more stably with chloroplast membranes and was proposed to promote interactions between ChlH and chloroplast membranes—the site of Mg-chelatase activity. GUN4 was also proposed to attenuate the production of reactive oxygen species (ROS) by binding and shielding light-exposed porphyrins from collisions with O2. To test these proposals, we first engineered Arabidopsis thaliana plants that express only porphyrin binding–deficient forms of GUN4. Using these transgenic plants and particular mutants, we found that the porphyrin binding activity of GUN4 and Mg-chelatase contribute to the accumulation of chlorophyll, GUN4, and Mg-chelatase subunits. Also, we found that the porphyrin binding activity of GUN4 and Mg-chelatase affect the associations of GUN4 and ChlH with chloroplast membranes and have various effects on the expression of ROS-inducible genes. Based on our findings, we conclude that ChlH and GUN4 use distinct mechanisms to associate with chloroplast membranes and that mutant alleles of GUN4 and Mg-chelatase genes cause sensitivity to intense light by a mechanism that is potentially complex. PMID:21467578

  12. Advanced Laser Technologies for High-brightness Photocathode Electron Gun

    NASA Astrophysics Data System (ADS)

    Tomizawa, Hiromitsu

    A laser-excited photocathode RF gun is one of the most reliable high-brightness electron beam sources for XFELs. Several 3D laser shaping methods have been developed as ideal photocathode illumination sources at SPring-8 since 2001. To suppress the emittance growth caused by nonlinear space-charge forces, the 3D cylindrical UV-pulse was optimized spatially as a flattop and temporally as squarely stacked chirped pulses. This shaping system is a serial combination of a deformable mirror that adaptively shapes the spatial profile with a genetic algorithm and a UV-pulse stacker that consists of four birefringent α-BBO crystal rods for temporal shaping. Using this 3D-shaped pulse, a normalized emittance of 1.4 π mm mrad was obtained in 2006. Utilizing laser's Z-polarization, Schottky-effect-gated photocathode gun was proposed in 2006. The cathode work functions are reduced by a laser-induced Schottky effect. As a result of focusing a radially polarized laser pulse with a hollow lens in vacuum, the Z-field (Z-polarization) is generated at the cathode.

  13. A Particle-In-Cell Gun Code for Surface-Converter H- Ion Source Modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chacon-Golcher, Edwin; Bowers, Kevin J.

    2007-08-10

    We present the current status of a particle-in-cell with Monte Carlo collisions (PIC-MCC) gun code under development at Los Alamos for the study of surface-converter H- ion sources. The program preserves a first-principles approach to a significant extent and simulates the production processes without ad hoc models within the plasma region. Some of its features include: solution of arbitrary electrostatic and magnetostatic fields in an axisymmetric (r,z) geometry to describe the self-consistent time evolution of a plasma; simulation of a multi-species (e-,H+,H{sub 2}{sup +},H{sub 3}{sup +},H-) plasma discharge from a neutral hydrogen gas and filament-originated seed electrons; full 2-dimensional (r,z)more » 3-velocity (vr,vz,v{phi}) dynamics for all species with exact conservation of the canonical angular momentum p{phi}; detailed collision physics between charged particles and neutrals and the ability to represent multiple smooth (not stair-stepped) electrodes of arbitrary shape and voltage whose surfaces may be secondary-particle emitters (H- and e-). The status of this development is discussed in terms of its physics content and current implementation details.« less

  14. The Status of Normal Conducting RF (NCRF) Guns, a Summary of the ERL2005 Workshop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dowell, D.H.; /SLAC; Lewellen, J.W.

    The 32nd Advanced ICFA Beam Dynamics Workshop on Energy Recovering Linacs (ERL2005) was held at Jefferson Laboratory, March 20 to 23, 2005. A wide range of ERL-related topics were presented and discussed in several working groups with Working Group 1 concentrated upon the physics and technology issues for DC, superconducting RF (SRF) and normal conducting RF (NCRF) guns. This paper summarizes the NCRF gun talks and reviews the status of NCRF gun technology. It begins with the presentations made on the subject of low-frequency, high-duty factor guns most appropriate for ERLs. One such gun at 433MHz was demonstrated at 25%DFmore » in 1992, while the CW and much improved version is currently being constructed at 700MHz for LANL. In addition, the idea of combining the NCRF gun with a SRF linac booster was presented and is described in this paper. There was also a talk on high-field guns typically used for SASE free electron lasers. In particular, the DESY coaxial RF feed design provides rotationally symmetric RF fields and greater flexibility in the placement of the focusing magnetic field. While in the LCLS approach, the symmetric fields are obtained with a dual RF feed and racetrack cell shape. Although these guns cannot be operated at high-duty factor, they do produce the best quality beams. With these limitations in mind, a section with material not presented at the workshop has been included in the paper. This work describes a re-entrant approach which may allow NCRF guns to operate with simultaneously increased RF fields and duty factors. And finally, a novel proposal describing a high-duty factor, two-frequency RF gun using a field emission source instead of a laser driven photocathode was also presented.« less

  15. The status of normal conducting RF (NCRF) guns; a summary of the ERL2005 Workshop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D.H. Dowell; J.W. Lewellen; D. Nguyen

    The 32nd Advanced ICFA Beam Dynamics Workshop on Energy Recovering Linacs (ERL2005) was held at Jefferson Laboratory, March 20 to 23, 2005. A wide range of ERL-related topics were presented and discussed in several working groups with Working Group 1 concentrated upon the physics and technology issues for DC, superconducting RF (SRF) and normal conducting RF (NCRF) guns. This paper summarizes the NCRF gun talks and reviews the status of NCRF gun technology. It begins with the presentations made on the subject of low-frequency, high-duty factor guns most appropriate for ERLs. One such gun at 433MHz was demonstrated at 25%DFmore » in 1992, while the CW and much improved version is currently being constructed at 700MHz for LANL. In addition, the idea of combining the NCRF gun with a SRF linac booster was presented and is described in this paper. There was also a talk on high-field guns typically used for SASE free electron lasers. In particular, the DESY coaxial RF feed design provides rotationally symmetric RF fields and greater flexibility in the placement of the focusing magnetic field. While in the LCLS approach, the symmetric fields are obtained with a dual RF feed and racetrack cell shape. Although these guns cannot be operated at high-duty factor, they do produce the best quality beams. With these limitations in mind, a section with material not presented at the workshop has been included in the paper. This work describes a re-entrant approach which may allow NCRF guns to operate with simultaneously increased RF fields and duty factors. And finally, a novel proposal describing a high-duty factor, two-frequency RF gun using a field emission source instead of a laser driven photocathode was also presented.« less

  16. The status of normal conducting RF (NCRF) guns, a summary of the ERL2005 workshop

    NASA Astrophysics Data System (ADS)

    Dowell, David H.; Lewellen, John W.; Nguyen, Dinh; Rimmer, Robert

    2006-02-01

    The 32nd Advanced ICFA Beam Dynamics Workshop on Energy Recovering Linacs (ERL2005) was held at Jefferson Laboratory, March 20-23, 2005. A wide range of ERL-related topics were presented and discussed in several working groups with Working Group 1 concentrating upon the physics and technology issues for DC, superconducting RF (SRF) and normal conducting RF (NCRF) guns. This paper summarizes the NCRF gun talks and reviews the status of NCRF gun technology. It begins with the presentations made on the subject of low-frequency, high-duty factor guns most appropriate for ERLs. One such gun at 433 MHz was demonstrated at 25%DF in 1992, while the CW and much improved version is currently being constructed at 700 MHz for LANL. In addition, the idea of combining the NCRF gun with a SRF linac booster was presented and is described in this paper. There was also a talk on high-field guns typically used for SASE-free electron lasers. In particular, the DESY coaxial RF feed design provides rotationally symmetric RF fields and greater flexibility in the placement of the focusing magnetic field. While in the LCLS approach, the symmetric fields are obtained with a dual RF feed and racetrack cell shape. Although these guns cannot be operated at high-duty factor, they do produce the best quality beams. With these limitations in mind, a section with material not presented at the workshop has been included in the paper. This work describes a re-entrant approach which may allow NCRF guns to operate with simultaneously increased RF fields and duty factors. And finally, a novel proposal describing a high-duty factor, two-frequency RF gun using a field emission source instead of a laser driven photocathode was also presented.

  17. Background Checks for all Gun Buyers and Gun Violence Restraining Orders: State Efforts to Keep Guns from High-Risk Persons.

    PubMed

    Vernick, Jon S; Alcorn, Ted; Horwitz, Joshua

    2017-03-01

    There were more than 36,000 firearm-related deaths in the U.S. in 2015. Under federal law, a background check is required only for gun purchases from licensed dealers. Research suggests that some persons prohibited from owning a gun turn to private sellers, including those identified online, to attempt to obtain a firearm. State-level approaches to make it more difficult for high-risk persons to purchase or possess firearms include universal background check (UBC) and gun violence restraining order (GVRO) laws. UBC laws, on the books in 18 states as of the end of 2016, can reduce both homicide and suicide rates. After Colorado adopted a UBC law in 2013, the number of background checks conducted by private sellers for sales occurring at places other than gun shows steadily increased. GVRO laws give law enforcement and families the authority to petition a court to temporarily remove firearms from an individual who presents a danger to himself or others during times of crisis, regardless of whether that person has been diagnosed with a mental illness. California enacted a GVRO law in 2014. Data are emerging to suggest the effectiveness of GVRO-type laws at averting suicides and providing an entryway to services.

  18. Extended suicide using an atypical stud gun.

    PubMed

    Hagemeier, L; Schyma, C; Madea, B

    2009-08-10

    Suicides with stud guns are uncommon, but are well documented in the literature. On rare occasions, stud guns are also used as a homicide weapon. This case report describes an extended suicide in which a husband killed his wife and their two dogs, which lived on the property. The husband then committed suicide with a shot from the stud gun into his skull. He was a 70-year-old pensioner, a retired butcher, who was found by his son. He was lying in a supine position on a carpet in the living room, with the stud gun stuck in his skull. During autopsy, high concentrations of an antihistamine were found in the blood of each corpse; this drug is used as a soporific. In contrast to the literature, which mainly describes powder deposits due to the use of conventional stud guns, in this case a stud gun was used in which the expanding gases and powder escaped together with the central bolt at the front of the device; powder drains were not involved. Detailed findings of the autopsy are given with reference to this type of stud gun.

  19. Ready, Fire, Aim: The College Campus Gun Fight

    ERIC Educational Resources Information Center

    Birnbaum, Robert

    2013-01-01

    The question of whether guns should be permitted on college and university campuses in the United States reflects the tension between two competing perspectives. America has both a robust gun culture and an equally robust (if less well known) gun-control culture. The gun culture is as American as apple pie: There may be as many as 300 million…

  20. Gas gun shock experiments with single-pulse x-ray phase contrast imaging and diffraction at the Advanced Photon Source

    NASA Astrophysics Data System (ADS)

    Luo, S. N.; Jensen, B. J.; Hooks, D. E.; Fezzaa, K.; Ramos, K. J.; Yeager, J. D.; Kwiatkowski, K.; Shimada, T.

    2012-07-01

    The highly transient nature of shock loading and pronounced microstructure effects on dynamic materials response call for in situ, temporally and spatially resolved, x-ray-based diagnostics. Third-generation synchrotron x-ray sources are advantageous for x-ray phase contrast imaging (PCI) and diffraction under dynamic loading, due to their high photon fluxes, high coherency, and high pulse repetition rates. The feasibility of bulk-scale gas gun shock experiments with dynamic x-ray PCI and diffraction measurements was investigated at the beamline 32ID-B of the Advanced Photon Source. The x-ray beam characteristics, experimental setup, x-ray diagnostics, and static and dynamic test results are described. We demonstrate ultrafast, multiframe, single-pulse PCI measurements with unprecedented temporal (<100 ps) and spatial (˜2 μm) resolutions for bulk-scale shock experiments, as well as single-pulse dynamic Laue diffraction. The results not only substantiate the potential of synchrotron-based experiments for addressing a variety of shock physics problems, but also allow us to identify the technical challenges related to image detection, x-ray source, and dynamic loading.

  1. The design of an electron gun switchable between immersed and Brillouin flowa)

    NASA Astrophysics Data System (ADS)

    Becker, R.; Kester, O.

    2012-02-01

    An electron gun, which can be switched from immersed flow to Brillouin flow during operation, may have advantages for charge breeders as well as for electron beam ion sources and traps (EBISTs). For EBISTs this allows to change the current density according to the repetition frequency and charge state, for charge breeders and EBISTs a lower current density in immersed flow provides higher acceptance for injected ions, while the higher current density in Brillouin flow results in shorter breeding times and a lower emittance for the extracted beam. Therefore, we have designed such a gun for an EBIS with 5 T central magnetic field and without the use of iron and moving the gun. The gun was placed in the axial fringing field of the 5 T solenoid in such a position that a gate valve can be placed between the gun and the cryostat to allow for simple maintenance. The field at the cathode surface turned out to be only 0.05 T, which is not enough to focus 50 A/cm2 at a few kV. However, if a small normal conducting solenoid is placed over the vacuum tube in position of the gun, a field of 0.1 T may be obtained. With this the use of LaB6 as cathode material results in a magnetic compression of 44 and therewith in a focused current density in the trap region of more than 2000 A/cm2. By reversing the current in the gun solenoid the cathode field can easily compensated to zero. By proper design of the electrodes and the compression region, the gun will be able to deliver a beam in Brillouin flow. While this is interesting by itself - remember the "super-compression" reported on CRYEBIS-I - any magnetic field between zero and the value for immersed flow will result in an electron beam with a wide range of adjustable high current densities. The design tools used have been INTMAG(C) for the calculation of magnetic fields, EGN2(C) for the simulation of the gun and ANALYSE(C) for detailed analysis of the results (for more information see www.egun-igun.com).

  2. The design of an electron gun switchable between immersed and Brillouin flow.

    PubMed

    Becker, R; Kester, O

    2012-02-01

    An electron gun, which can be switched from immersed flow to Brillouin flow during operation, may have advantages for charge breeders as well as for electron beam ion sources and traps (EBISTs). For EBISTs this allows to change the current density according to the repetition frequency and charge state, for charge breeders and EBISTs a lower current density in immersed flow provides higher acceptance for injected ions, while the higher current density in Brillouin flow results in shorter breeding times and a lower emittance for the extracted beam. Therefore, we have designed such a gun for an EBIS with 5 T central magnetic field and without the use of iron and moving the gun. The gun was placed in the axial fringing field of the 5 T solenoid in such a position that a gate valve can be placed between the gun and the cryostat to allow for simple maintenance. The field at the cathode surface turned out to be only 0.05 T, which is not enough to focus 50 A∕cm(2) at a few kV. However, if a small normal conducting solenoid is placed over the vacuum tube in position of the gun, a field of 0.1 T may be obtained. With this the use of LaB(6) as cathode material results in a magnetic compression of 44 and therewith in a focused current density in the trap region of more than 2000 A∕cm(2). By reversing the current in the gun solenoid the cathode field can easily compensated to zero. By proper design of the electrodes and the compression region, the gun will be able to deliver a beam in Brillouin flow. While this is interesting by itself--remember the "super-compression" reported on CRYEBIS-I--any magnetic field between zero and the value for immersed flow will result in an electron beam with a wide range of adjustable high current densities. The design tools used have been INTMAG(C) for the calculation of magnetic fields, EGN2(C) for the simulation of the gun and ANALYSE(C) for detailed analysis of the results (for more information see www.egun-igun.com).

  3. Electron gun jitter effects on beam bunching

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, M. S.; Iqbal, M., E-mail: muniqbal.chep@pu.edu.pk; Centre for High Energy Physics, University of the Punjab, Lahore 45590

    For routine operation of Beijing Electron Positron Collider II (BEPCII) linac, many factors may affect the beam bunching process directly or indirectly. We present the measurements and analyses of the gun timing jitter, gun high voltage jitter, and beam energy at the exit of the standard acceleration section of the linac quantitatively. Almost 80 mV and more than 200 ps of gun high voltage and time jitters have ever been measured, respectively. It was analyzed that the gun timing jitter produced severe effects on beam energy than the gun high voltage jitter, if the timing jitter exceeded 100 ps whichmore » eventually deteriorates both the beam performance and the injection rate to the storage ring.« less

  4. Numerical investigation of a laser gun injector at CEBAF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Byung Yunn; Charles Sinclair; David Neuffer

    1993-08-23

    A laser gun injector is being developed based on the superconducting rf technologies established at CEBAF. This injector will serve as a high charge cw source for a high power free electron laser. It consists of a dc laser gun, a buncher, a cryounit and a chicane. Its space-charge-dominated performance has been thoroughly investigated using the time-consuming but more appropriate point-by-point space charge calculation method in PARMELA. The notion of ``conditioning for final bunching'' will be introduced. This concept has been built into the code and has greatly facilitated the optimization of the whole system to achieve the highest possiblemore » peak current while maintaining low emittance and low energy spread. Extensive parameter variation studies have shown that the design will perform better than the specifications.« less

  5. Higher-order mode rf guns

    NASA Astrophysics Data System (ADS)

    Lewellen, John W.

    2001-04-01

    Traditional photocathode rf gun design is based around the use of TM0,1,0-mode cavities. This is typically done in the interest of obtaining the highest possible gradient per unit supplied rf power and for historical reasons. In a multicell, aperture-coupled photoinjector, however, the gun as a whole is produced from strongly coupled cavities oscillating in a π mode. This design requires very careful preparation and tuning, as the field balance and resonant frequencies are easily disturbed. Side-coupled designs are often avoided because of the dipole modes introduced into the cavity fields. This paper proposes the use of a single higher-order mode rf cavity in order to generate the desired on-axis fields. It is shown that the field experienced by a beam in a higher-order mode rf gun is initially very similar to traditional 1.5- or 2.5-cell π-mode gun fields, and projected performance in terms of beam quality is also comparable. The new design has the advantages of much greater ease of fabrication, immunity from coupled-cell effects, and simpler tuning procedures. Because of the gun geometry, the possibility also exists for improved temperature stabilization and cooling for high duty-cycle applications.

  6. An ultrafast electron microscope gun driven by two-photon photoemission from a nanotip cathode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bormann, Reiner; Strauch, Stefanie; Schäfer, Sascha, E-mail: schaefer@ph4.physik.uni-goettingen.de

    We experimentally and numerically investigate the performance of an advanced ultrafast electron source, based on two-photon photoemission from a tungsten needle cathode incorporated in an electron microscope gun geometry. Emission properties are characterized as a function of the electrostatic gun settings, and operating conditions leading to laser-triggered electron beams of very low emittance (below 20 nm mrad) are identified. The results highlight the excellent suitability of optically driven nano-cathodes for the further development of ultrafast transmission electron microscopy.

  7. Cobalt-Base Alloy Gun Barrel Study

    DTIC Science & Technology

    2014-07-01

    Cobalt-Base Alloy Gun Barrel Study by William S. de Rosset and Jonathan S. Montgomery ARL-RP-0491 July 2014 A reprint...21005-5069 ARL-RP-0491 July 2014 Cobalt-Base Alloy Gun Barrel Study William S. de Rosset and Jonathan S. Montgomery Weapons and Materials... Gun Barrel Study 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) William S. de Rosset and Jonathan S. Montgomery

  8. Demonstration of Advanced Technologies for Multi-Load Washers in Hospitality and Healthcare -- Wastewater Recycling Technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyd, Brian K.; Parker, Graham B.; Petersen, Joseph M.

    The objective of this demonstration project was to evaluate market-ready retrofit technologies for reducing the energy and water use of multi-load washers in healthcare and hospitality facilities. Specifically, this project evaluated laundry wastewater recycling technology in the hospitality sector and ozone laundry technology in both the healthcare and hospitality sectors. This report documents the demonstration of a wastewater recycling system installed in the Grand Hyatt Seattle.

  9. A Guillemin type E pulse forming network as the driver for a pulsed, high density plasma source.

    PubMed

    Rathod, Priyavandna J; Anitha, V P; Sholapurwala, Z H; Saxena, Y C

    2014-06-01

    A Guillemin type E pulse forming network (PFN) has been designed, developed, and tested for its application in generating high density (~1 × 10(18) m(-3)) plasmas. In the present study, plasma thus generated is utilized to investigate the interaction of high power microwaves (HPMs) with plasma in an experimental architecture known as SYMPLE (System for Microwave PLasma Experiment). Plasma discharges of ~100 μs (max) duration are to be produced, by delivering energy of 5 kJ stored in a PFN to the plasma source, a washer gun. The output of the PFN, in terms of its rise time, flat top and amplitude, needs to be tailored, depending on the experimental requirements. An ignitron (NL8900) trigger generator (ITG) is developed in-house to control the PFN discharge through the gun. This ITG is also to be used in a circuit that synchronizes the HPM and plasma shots, to ensure that HPM-plasma interaction takes place during a temporal regime where appropriate parametric conditions are satisfied. Hence it is necessary to retain the jitter within ±2.5 μs. Further, requirement on plasma quiescence (~10%) necessitates maintaining the ripple within 5%. The developmental work of the PFN, keeping in view the above criteria and the test results, is presented in this paper. The parameters of the PFN have been analytically approximated and verified with PSPICE simulation. The test results presented include rise time ~5-8 μs, flat top variable in the range 20-100 μs, ripple within ~1.5%, and jitter within ±2.5 μs, producing quiescent (<10%) plasma discharge meeting the experimental requirements.

  10. Development program on a cold cathode electron gun

    NASA Technical Reports Server (NTRS)

    Spindt, C. A.

    1979-01-01

    A prototype electron gun with a field emitter cathode capable of producing 95 mA in a 1/4 mm diameter beam at 12 kV was produced. Achievement of this goal required supporting studies in cathode fabrication, cathode performance, gun design, cathode mounting and gun fabrication. A series of empirical investigations advanced fabrication technology: More stable emitters were produced and multiple cone failure caused by chain reaction discharges were reduced. The cathode is capable of producing well over 95 mA, but a substantial collector development effort was required to demonstrate emission levels in the 100 mA region. Space charge problems made these levels difficult to achieve. Recommendations are made for future process and materials investigation. Electron gun designs were modeled and tested. A pair of two-electrode gun structures were fabricated and tested; one gun was delivered to NASA. Cathodes were pretested up to 100 mA at SRI and delivered to NASA for test in the gun structure.

  11. Arc-driven rail gun research

    NASA Technical Reports Server (NTRS)

    Ray, P. K.

    1984-01-01

    The equations describing the performance of an inductively-driven rail gun are analyzed numerically. Friction between the projectile and rails is included through an empirical formulation. The equations are applied to the experiment of Rashleigh and Marshall to obtain an estimate of energy distribution in rail guns as a function of time. The effect of frictional heat dissipation on the bore of the gun is calculated. The mechanism of plasma and projectile acceleration in a dc rail gun is described from a microscopic point of view through the establishment of the Hall field. The plasma conductivity is shown to be a tensor indicating that there is a small component of current parallel to the direction of acceleration. The plasma characteristics are evaluated as a function of plasma mass through a simple fluid mechanical analysis of the plasma. By equating the energy dissipated in the plasma with the radiation heat loss, the properties of the plasma are determined.

  12. Gun Possession among American Youth: A Discovery-Based Approach to Understand Gun Violence

    PubMed Central

    Ruggles, Kelly V.; Rajan, Sonali

    2014-01-01

    Objective To apply discovery-based computational methods to nationally representative data from the Centers for Disease Control and Preventions’ Youth Risk Behavior Surveillance System to better understand and visualize the behavioral factors associated with gun possession among adolescent youth. Results Our study uncovered the multidimensional nature of gun possession across nearly five million unique data points over a ten year period (2001–2011). Specifically, we automated odds ratio calculations for 55 risk behaviors to assemble a comprehensive table of associations for every behavior combination. Downstream analyses included the hierarchical clustering of risk behaviors based on their association “fingerprint” to 1) visualize and assess which behaviors frequently co-occur and 2) evaluate which risk behaviors are consistently found to be associated with gun possession. From these analyses, we identified more than 40 behavioral factors, including heroin use, using snuff on school property, having been injured in a fight, and having been a victim of sexual violence, that have and continue to be strongly associated with gun possession. Additionally, we identified six behavioral clusters based on association similarities: 1) physical activity and nutrition; 2) disordered eating, suicide and sexual violence; 3) weapon carrying and physical safety; 4) alcohol, marijuana and cigarette use; 5) drug use on school property and 6) overall drug use. Conclusions Use of computational methodologies identified multiple risk behaviors, beyond more commonly discussed indicators of poor mental health, that are associated with gun possession among youth. Implications for prevention efforts and future interdisciplinary work applying computational methods to behavioral science data are described. PMID:25372864

  13. Gun possession among American youth: a discovery-based approach to understand gun violence.

    PubMed

    Ruggles, Kelly V; Rajan, Sonali

    2014-01-01

    To apply discovery-based computational methods to nationally representative data from the Centers for Disease Control and Preventions' Youth Risk Behavior Surveillance System to better understand and visualize the behavioral factors associated with gun possession among adolescent youth. Our study uncovered the multidimensional nature of gun possession across nearly five million unique data points over a ten year period (2001-2011). Specifically, we automated odds ratio calculations for 55 risk behaviors to assemble a comprehensive table of associations for every behavior combination. Downstream analyses included the hierarchical clustering of risk behaviors based on their association "fingerprint" to 1) visualize and assess which behaviors frequently co-occur and 2) evaluate which risk behaviors are consistently found to be associated with gun possession. From these analyses, we identified more than 40 behavioral factors, including heroin use, using snuff on school property, having been injured in a fight, and having been a victim of sexual violence, that have and continue to be strongly associated with gun possession. Additionally, we identified six behavioral clusters based on association similarities: 1) physical activity and nutrition; 2) disordered eating, suicide and sexual violence; 3) weapon carrying and physical safety; 4) alcohol, marijuana and cigarette use; 5) drug use on school property and 6) overall drug use. Use of computational methodologies identified multiple risk behaviors, beyond more commonly discussed indicators of poor mental health, that are associated with gun possession among youth. Implications for prevention efforts and future interdisciplinary work applying computational methods to behavioral science data are described.

  14. Gun ownership and firearm-related deaths.

    PubMed

    Bangalore, Sripal; Messerli, Franz H

    2013-10-01

    A variety of claims about possible associations between gun ownership rates, mental illness burden, and the risk of firearm-related deaths have been put forward. However, systematic data on this issue among various countries remain scant. Our objective was to assess whether the popular notion "guns make a nation safer" has any merits. Data on gun ownership were obtained from the Small Arms Survey, and for firearm-related deaths from a European detailed mortality database (World Health Organization), the National Center for Health Statistics, and others. Crime rate was used as an indicator of safety of the nation and was obtained from the United Nations Surveys of Crime Trends. Age-standardized disability-adjusted life-year rates due to major depressive disorder per 100,000 inhabitants with data obtained from the World Health Organization database were used as a putative indicator for mental illness burden in a given country. Among the 27 developed countries, there was a significant positive correlation between guns per capita per country and the rate of firearm-related deaths (r = 0.80; P <.0001). In addition, there was a positive correlation (r = 0.52; P = .005) between mental illness burden in a country and firearm-related deaths. However, there was no significant correlation (P = .10) between guns per capita per country and crime rate (r = .33), or between mental illness and crime rate (r = 0.32; P = .11). In a linear regression model with firearm-related deaths as the dependent variable with gun ownership and mental illness as independent covariates, gun ownership was a significant predictor (P <.0001) of firearm-related deaths, whereas mental illness was of borderline significance (P = .05) only. The number of guns per capita per country was a strong and independent predictor of firearm-related death in a given country, whereas the predictive power of the mental illness burden was of borderline significance in a multivariable model. Regardless of exact

  15. Improved Orifice Plate for Spray Gun

    NASA Technical Reports Server (NTRS)

    Cunningham, W.

    1986-01-01

    Erratic spray pattern of commercial spray gun changed to repeatable one by simple redesign of two parts. In modified spray gun orifice plate and polytetrafluoroethylene bushing redesigned to assure centering and alignment with nozzle. Such improvement useful in many industrial applications requiring repeatable spray patterns. Might include spraying of foam insulation, paint, other protective coatings, detergents, abrasives, adhesives, process chemicals, or fuels. Unmodified spray gun produces erratic spray because lateral misalignment between orifice plate and nozzle.

  16. Frequency of Guns in the Households of High School Seniors*

    PubMed Central

    Coker, Ann L.; Bush, Heather M.; Follingstad, Diane R.; Brancato, Candace J.

    2017-01-01

    BACKGROUND In 2013, President Obama lifted the federal ban on gun violence research. The current study provides one of the first reports to estimate household gun ownership as reported by youth. METHODS In this cohort study of 3006 high school seniors from 24 schools, we examined the frequency of household guns ownership. RESULTS About 65% reported having at least 1 gun in their household. White males were more likely to have a gun and to have more guns than other demographically characterized groups. After adjustment for race and sex, those of higher income, who lived in suburban or rural areas, identified as being exclusively attracted to the opposite sex, and in a romantic relationship, were more likely to have a gun in their household. Having a gun was not associated with increasing symptoms of depression or current poor physical or mental health. CONCLUSIONS Whereas we cannot determine gun types or reasons for having a gun, this research indicates that high school seniors are aware of and may have access to guns for use other than their intended purpose. Household gun ownership among students at higher risk for violence may pose safety challenges for communities and schools. PMID:28147456

  17. Frequency of Guns in the Households of High School Seniors.

    PubMed

    Coker, Ann L; Bush, Heather M; Follingstad, Diane R; Brancato, Candace J

    2017-03-01

    In 2013, President Obama lifted the federal ban on gun violence research. The current study provides one of the first reports to estimate household gun ownership as reported by youth. In this cohort study of 3006 high school seniors from 24 schools, we examined the frequency of household guns ownership. About 65% reported having at least 1 gun in their household. White males were more likely to have a gun and to have more guns than other demographically characterized groups. After adjustment for race and sex, those of higher income, who lived in suburban or rural areas, identified as being exclusively attracted to the opposite sex, and in a romantic relationship, were more likely to have a gun in their household. Having a gun was not associated with increasing symptoms of depression or current poor physical or mental health. Whereas we cannot determine gun types or reasons for having a gun, this research indicates that high school seniors are aware of and may have access to guns for use other than their intended purpose. Household gun ownership among students at higher risk for violence may pose safety challenges for communities and schools. © 2017, American School Health Association.

  18. Unintentional Gun Deaths among Children. Firearm Facts.

    ERIC Educational Resources Information Center

    Duker, Laurie, Ed.

    Children are at risk of being killed or injured by a gun if their parents own a gun because many guns obtained for self-defense are kept loaded and within reach of children. This brief fact sheet presents statistical information relating to accidental deaths involving young people and firearms. Safety measures are suggested for preventing…

  19. Mole gun injury.

    PubMed

    Pistré, V; Rezzouk, J

    2013-09-01

    A mole gun is a weapon, which is used to trap and kill moles. This report provides an overview of the state of knowledge of mole gun injuries, comparable to blast injuries caused by fireworks, explosive or gunshot. Over a 2-year period, the authors reported their experience with ten hand injuries caused by mole gun. Radial side of the hand was often concerned, particularly the thumb. The authors explain their choices in the management of such lesions. Surgery was performed primarily and a large debridement currently seemed to offer the best outcome for the patient. Blast, crush, burns and lacerations may explain the higher rate of amputation to the digits. A long period of physiotherapy, specifically of the hand, was needed before the patient could return to work. This ballistic hand trauma encountered by surgeons requires knowledge and understanding of these injuries. It should be in accordance with firearms law because of severe injuries encountered and possible lethal wounds. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  20. 77 FR 75988 - Notice of Final Determination of Sales at Less Than Fair Value: Large Residential Washers From...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-26

    ... externally mounted steel frame at least six inches high that is designed to house a coin/token operated... washer-dryers'' denotes distinct washing and drying machines that are built on a unitary frame and share... of steel and is assembled with security fasteners;\\7\\ or \\6\\ ``Payment system electronics'' denotes a...

  1. 77 FR 76288 - Notice of Final Determination of Sales at Less Than Fair Value: Large Residential Washers from...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-27

    ... externally mounted steel frame at least six inches high that is designed to house a coin/token operated... ``stacked washer-dryers'' denotes distinct washing and drying machines that are built on a unitary frame and... of steel and is assembled with security fasteners;\\7\\ or \\6\\ ``Payment system electronics'' denotes a...

  2. "Gun-shooting hearing loss": A pilot study.

    PubMed

    Sataloff, Joseph; Hawkshaw, Mary J; Sataloff, Robert T

    2010-01-01

    Gun-shooting deafness is the common terminology applied to sensorineural hearing loss caused by shooting firearms. Many characteristics of gun-shooting hearing loss have been proposed, but they have not been defined clearly or established conclusively. We studied 37 users of recreational firearms to obtain pilot data to help determine if it is true that right-handed gun shooters develop more hearing loss in the left ear and vice versa, whether everyone who frequently shoots guns develops sensorineural hearing loss, and whether significant hearing loss is typically prevented by wearing commercially available ear protectors while shooting.

  3. Patterns of gun deaths across US counties 1999-2013.

    PubMed

    Kalesan, Bindu; Galea, Sandro

    2017-05-01

    We examined the socio-demographic distribution of gun deaths across 3143 counties in 50 United States' states to understand the spatial patterns and correlates of high and low gun deaths. We used aggregate counts of gun deaths and population in all counties from 1999 to 2013 from the Centers for Disease Control and Prevention's Wide-ranging Online Data for Epidemiologic Research (WONDER). We characterized four levels of gun violence, as distinct levels of gun death rates of relatively safe, unsafe, violent, and extremely violent counties, based on quartiles of 15-year county-specific gun death rates per 100,000 and used negative binomial regression models allowing clustering by state to calculate incidence rate ratios and 95% confidence intervals (95% CIs). Most states had at least one violent or extremely violent county. Extremely violent gun counties were mostly rural, poor, predominantly minority, had high unemployment rate and homicide rate. Overall, homicide rate was significantly associated with gun deaths (incidence rate ratios = 1.08, 95% CI = 1.06-1.09). In relatively safe counties, this risk was 1.09 (95% CI = 1.05-1.13) and in extremely violent gun counties was 1.03 (95% CI = 1.03-1.04). There are broad differences in gun death rates across the United States representing different levels of gun death rates in each state with distinct socio-demographic profiles. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Acute Alcohol Consumption, Alcohol Outlets, and Gun Suicide

    PubMed Central

    Branas, Charles C.; Richmond, Therese S.; Ten Have, Thomas R.; Wiebe, Douglas J.

    2014-01-01

    A case–control study of 149 intentionally self-inflicted gun injury cases (including completed gun suicides) and 302 population-based controls was conducted from 2003 to 2006 in a major US city. Two focal independent variables, acute alcohol consumption and alcohol outlet availability, were measured. Conditional logistic regression was adjusted for confounding variables. Gun suicide risk to individuals in areas of high alcohol outlet availability was less than the gun suicide risk they incurred from acute alcohol consumption, especially to excess. This corroborates prior work but also uncovers new information about the relationships between acute alcohol consumption, alcohol outlets, and gun suicide. Study limitations and implications are discussed. PMID:21929327

  5. Acute alcohol consumption, alcohol outlets, and gun suicide.

    PubMed

    Branas, Charles C; Richmond, Therese S; Ten Have, Thomas R; Wiebe, Douglas J

    2011-01-01

    A case-control study of 149 intentionally self-inflicted gun injury cases (including completed gun suicides) and 302 population-based controls was conducted from 2003 to 2006 in a major US city. Two focal independent variables, acute alcohol consumption and alcohol outlet availability, were measured. Conditional logistic regression was adjusted for confounding variables. Gun suicide risk to individuals in areas of high alcohol outlet availability was less than the gun suicide risk they incurred from acute alcohol consumption, especially to excess. This corroborates prior work but also uncovers new information about the relationships between acute alcohol consumption, alcohol outlets, and gun suicide. Study limitations and implications are discussed.

  6. Separating Batterers and Guns: A Review and Analysis of Gun Removal Laws in 50 States

    ERIC Educational Resources Information Center

    Frattaroli, Shannon; Vernick, Jon S.

    2006-01-01

    Firearms play an important role in lethal domestic violence incidents. The authors review state laws regarding two policies to separate batterers from firearms: laws authorizing police to remove firearms when responding to a domestic violence complaint ("police gun removal laws") and laws authorizing courts to order guns removed from batterers…

  7. Spot-Welding Gun Is Easy To Use

    NASA Technical Reports Server (NTRS)

    Morgan, Gene E.; Nguyen, Francis H.

    1991-01-01

    Electrical-resistance spot-welding gun designed to produce more welds per unit time by decreasing technician's effort and fatigue. Vacuum cups on frame secure welding gun to workpiece while compressed air drives welding tip against workpiece to make spot resistance weld. When weld completed, vacuum in frame cups released so frame and gun moved to position of next spot weld.

  8. Magnetized Target Fusion Propulsion: Plasma Injectors for MTF Guns

    NASA Technical Reports Server (NTRS)

    Griffin, Steven T.

    2003-01-01

    To achieve increased payload size and decreased trip time for interplanetary travel, a low mass, high specific impulse, high thrust propulsion system is required. This suggests the need for research into fusion as a source of power and high temperature plasma. The plasma would be deflected by magnetic fields to provide thrust. Magnetized Target Fusion (MTF) research consists of several related investigations into these topics. These include the orientation and timing of the plasma guns and the convergence and interface development of the "pusher" plasma. Computer simulations of the gun as it relates to plasma initiation and repeatability are under investigation. One of the items under development is the plasma injector. This is a surface breakdown driven plasma generator designed to function at very low pressures. The performance, operating conditions and limitations of these injectors need to be determined.

  9. High-voltage testing of a 500-kV dc photocathode electron gun.

    PubMed

    Nagai, Ryoji; Hajima, Ryoichi; Nishimori, Nobuyuki; Muto, Toshiya; Yamamoto, Masahiro; Honda, Yosuke; Miyajima, Tsukasa; Iijima, Hokuto; Kuriki, Masao; Kuwahara, Makoto; Okumi, Shoji; Nakanishi, Tsutomu

    2010-03-01

    A high-voltage dc photocathode electron gun was successfully conditioned up to a voltage of 550 kV and a long-time holding test for 8 h was demonstrated at an acceleration voltage of 500 kV. The dc photocathode electron gun is designed for future light sources based on energy-recovery linac and consists of a Cockcroft-Walton generator, a segmented cylindrical ceramic insulator, guard-ring electrodes, a support-rod electrode, a vacuum chamber, and a pressurized insulating gas tank. The segmented cylindrical ceramic insulator and the guard-ring electrodes were utilized to prevent any damage to the insulator from electrons emitted by the support-rod electrode.

  10. Sequential injection gas guns for accelerating projectiles

    DOEpatents

    Lacy, Jeffrey M [Idaho Falls, ID; Chu, Henry S [Idaho Falls, ID; Novascone, Stephen R [Idaho Falls, ID

    2011-11-15

    Gas guns and methods for accelerating projectiles through such gas guns are described. More particularly, gas guns having a first injection port located proximate a breech end of a barrel and a second injection port located longitudinally between the first injection port and a muzzle end of the barrel are described. Additionally, modular gas guns that include a plurality of modules are described, wherein each module may include a barrel segment having one or more longitudinally spaced injection ports. Also, methods of accelerating a projectile through a gas gun, such as injecting a first pressurized gas into a barrel through a first injection port to accelerate the projectile and propel the projectile down the barrel past a second injection port and injecting a second pressurized gas into the barrel through the second injection port after passage of the projectile and to further accelerate the projectile are described.

  11. Toroid Joining Gun For Fittings And Couplings

    NASA Technical Reports Server (NTRS)

    Fox, Robert L.; Swaim, Robert J.; Johnson, Samuel D.; Buckley, John D.; Copeland, Carl E.; Coultrip, Robert H.; Johnston, David F.; Phillips, William M.

    1992-01-01

    Hand-held gun used to join metal heat-to-shrink couplings. Uses magnetic induction (eddy currents) to produce heat in metal coupling, and thermocouple to measure temperature and signals end of process. Gun, called "toroid joining gun" concentrates high levels of heat in localized areas. Reconfigured for use on metal heat-to-shrink fitting and coupling applications. Provides rapid heating, operates on low power, lightweight and portable. Safe for use around aircraft fuel and has no detrimental effects on surrounding surfaces or objects. Reliable in any environment and under all weather conditions. Gun logical device for taking full advantage of capabilities of new metal heat-to-shrink couplings and fittings.

  12. NASA-Ames vertical gun

    NASA Technical Reports Server (NTRS)

    Schultz, P. H.

    1984-01-01

    A national facility, the NASA-Ames vertical gun range (AVGR) has an excellent reputation for revealing fundamental aspects of impact cratering that provide important constraints for planetary processes. The current logistics in accessing the AVGR, some of the past and ongoing experimental programs and their relevance, and the future role of this facility in planetary studies are reviewed. Publications resulting from experiments with the gun (1979 to 1984) are listed as well as the researchers and subjects studied.

  13. Gun Concerns Personal for Duncan

    ERIC Educational Resources Information Center

    McNeil, Michele

    2013-01-01

    As U.S. Secretary of Education Arne Duncan works with other Obama administration officials on policy responses to the shootings at a Connecticut elementary school, he brings a personal and professional history that has acquainted him with the impact of gun violence. As schools chief in Chicago from 2001 to 2008, he was affected by the gun deaths…

  14. Gun Safety Management with Patients at Risk for Suicide

    ERIC Educational Resources Information Center

    Simon, Robert I.

    2007-01-01

    Guns in the home are associated with a five-fold increase in suicide. All patients at risk for suicide must be asked if guns are available at home or easily accessible elsewhere, or if they have intent to buy or purchase a gun. Gun safety management requires a collaborative team approach including the clinician, patient, and designated person…

  15. Broadband spectra of seismic survey air-gun emissions, with reference to dolphin auditory thresholds.

    PubMed

    Goold, J C; Fish, P J

    1998-04-01

    Acoustic emissions from a 2120 cubic in air-gun array were recorded through a towed hydrophone assembly during an oil industry 2-D seismic survey off the West Wales Coast of the British Isles. Recorded seismic pulses were sampled, calibrated, and analyzed post-survey to investigate power levels of the pulses in the band 200 Hz-22 kHz at 750-m, 1-km, 2.2-km, and 8-km range from source. At 750-m range from source, seismic pulse power at the 200-Hz end of the spectrum was 140 dB re: 1 microPa2/Hz, and at the 20-kHz end of the spectrum seismic pulse power was 90 dB re: 1 microPa2/Hz. Although the background noise levels of the seismic recordings were far in excess of ambient, due to the proximity of engine, propeller, and flow sources of the ship towing the hydrophone, seismic power dominated the entire recorded bandwidth of 200 Hz-22 kHz at ranges of up to 2 km from the air-gun source. Even at 8-km range seismic power was still clearly in excess of the high background noise levels up to 8 kHz. Acoustic observations of common dolphins during preceding seismic surveys suggest that these animals avoided the immediate vicinity of the air-gun array while firing was in progress, i.e., localized disturbance occurred during seismic surveying. Although a general pattern of localized disturbance is suggested, one specific observation revealed that common dolphins were able to tolerate the seismic pulses at 1-km range from the air-gun array. Given the high broadband seismic pulse power levels across the entire recorded bandwidth, and known auditory thresholds for several dolphin species, we consider such seismic emissions to be clearly audible to dolphins across a bandwidth of tens on kilohertz, and at least out to 8-km range.

  16. Development of spray guns for the application of rigid foam insulation

    NASA Technical Reports Server (NTRS)

    Allen, Peter B.

    1993-01-01

    The paper describes the activities initiated to improve the existing spray gun system used for spraying insulating foam on the External Tank of the Space Shuttle, due to the quality variations of the applied foam noted in the past. Consideration is given to the two tasks of the project: (1) investigations of possible improvements, as an interim measure, to the spray gun currently used to apply the large acreage spray-on-foam insulation and the evaluation of other commercial equipment; and (2) the design and fabrication of a new automatic spray gun. The design and operation of the currently used Binks 43 PA spray gun are described together with several new breadboard spray guns designed and fabricated and the testing procedures developed. These new guns include the Modular Automatic Foam spray gun, the Ball Valve spray gun, and the Tapered Plug Valve (TPV) gun. As a result of tests, the TPV spray gun is recommended to replace the currently used automatic spray gun.

  17. Performance of a carbon nanotube field emission electron gun

    NASA Astrophysics Data System (ADS)

    Getty, Stephanie A.; King, Todd T.; Bis, Rachael A.; Jones, Hollis H.; Herrero, Federico; Lynch, Bernard A.; Roman, Patrick; Mahaffy, Paul

    2007-04-01

    A cold cathode field emission electron gun (e-gun) based on a patterned carbon nanotube (CNT) film has been fabricated for use in a miniaturized reflectron time-of-flight mass spectrometer (RTOF MS), with future applications in other charged particle spectrometers, and performance of the CNT e-gun has been evaluated. A thermionic electron gun has also been fabricated and evaluated in parallel and its performance is used as a benchmark in the evaluation of our CNT e-gun. Implications for future improvements and integration into the RTOF MS are discussed.

  18. Comparison of washer-disinfector cleaning indicators: impact of temperature and cleaning cycle parameters.

    PubMed

    Alfa, Michelle J; Olson, Nancy

    2014-02-01

    Because automated instrument washer-disinfectors (WD) are widely used in health care to reprocess a variety of medical instruments, we developed a study to compare 3 cleaning indicators to determine whether they detected suboptimal temperature, time, enzymatic detergent, and fluid action in a washer-disinfector. The Miele WD was used for this comparison. One optimal cycle and 14 cycles with suboptimal enzymatic detergent, cleaning time, temperature, or inactive spray arms were evaluated. The cleaning indicators evaluated included the following: Pinnacle Monitor for Automated Enzymatic Cleaning Process (PNCL), Wash-Checks (WC), and TOSI. The scoring system for all 3 indicators was harmonized to a common scale. Soiled tweezers were included in each cycle evaluated. The PNCL, TOSI, and WC cleaning indicators showed significantly more failures at 40°C compared with 60°C (100% vs 0% for PNCL, 17% vs 0% for TOSI, and 60% vs 22% for WC, respectively). There were significantly more failures at suboptimal temperatures with a 2- versus 4-minute cycle (100% vs 0% for PNCL, 17% vs 0% for TOSI, and 17% vs 0% for WC, respectively, for 40°C cycles). Despite suboptimal cleaning cycles, all soiled tweezers looked clean. All 3 cleaning indicators responded to suboptimal WD conditions; however, the PNCL was the most affected by alterations in the cycle conditions evaluated. In simulated use testing, cleaning indicators provided a more sensitive audit tool compared with visual inspection of soiled instruments after automated cleaning. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  19. Law Enforcement and Gun Retailers as Partners for Safely Storing Guns to Prevent Suicide: A Study in 8 Mountain West States.

    PubMed

    Runyan, Carol W; Brooks-Russell, Ashley; Brandspigel, Sara; Betz, Marian; Tung, Gregory; Novins, Douglas; Agans, Robert

    2017-11-01

    To examine the extent to which law enforcement agencies (LEAs) and gun retailers are willing to offer voluntary, temporary storage as a part of an overall suicide prevention effort. We invited all LEAs and gun retailers in 8 US states to respond to questionnaires asking about their willingness to offer temporary gun storage and their recommendations to gun owners about safe storage. We collected data in 2016 from 448 LEAs and 95 retailers (response rates of 53% and 25%, respectively). Three quarters of LEAs (74.8%; 95% confidence interval [CI] = 72.1, 77.5) indicated they already provided temporary storage compared with 47.6% (95% CI = 39.2, 56.0) of retailers. LEAs were most willing to provide storage when a gun owner was concerned about the mental health of a family member. Retailers were more receptive than were LEAs to providing storage when visitors were coming or for people wanting storage while traveling. Both groups recommended locking devices within the home, but LEAs were slightly more favorable to storing guns away from the home. Law enforcement agencies and gun retailers are important resources for families concerned about suicide.

  20. X-band RF gun and linac for medical Compton scattering X-ray source

    NASA Astrophysics Data System (ADS)

    Dobashi, Katsuhito; Uesaka, Mitsuru; Fukasawa, Atsushi; Sakamoto, Fumito; Ebina, Futaro; Ogino, Haruyuki; Urakawa, Junji; Higo, Toshiyasu; Akemoto, Mitsuo; Hayano, Hitoshi; Nakagawa, Keiichi

    2004-12-01

    Compton scattering hard X-ray source for 10-80 keV are under construction using the X-band (11.424 GHz) electron linear accelerator and YAG laser at Nuclear Engineering Research laboratory, University of Tokyo. This work is a part of the national project on the development of advanced compact medical accelerators in Japan. National Institute for Radiological Science is the host institute and U.Tokyo and KEK are working for the X-ray source. Main advantage is to produce tunable monochromatic hard (10-80 keV) X-rays with the intensities of 108-1010 photons/s (at several stages) and the table-top size. Second important aspect is to reduce noise radiation at a beam dump by adopting the deceleration of electrons after the Compton scattering. This realizes one beamline of a 3rd generation SR source at small facilities without heavy shielding. The final goal is that the linac and laser are installed on the moving gantry. We have designed the X-band (11.424 GHz) traveling-wave-type linac for the purpose. Numerical consideration by CAIN code and luminosity calculation are performed to estimate the X-ray yield. X-band thermionic-cathode RF-gun and RDS(Round Detuned Structure)-type X-band accelerating structure are applied to generate 50 MeV electron beam with 20 pC microbunches (104) for 1 microsecond RF macro-pulse. The X-ray yield by the electron beam and Q-switch Nd:YAG laser of 2 J/10 ns is 107 photons/RF-pulse (108 photons/sec at 10 pps). We design to adopt a technique of laser circulation to increase the X-ray yield up to 109 photons/pulse (1010 photons/s). 50 MW X-band klystron and compact modulator have been constructed and now under tuning. The construction of the whole system has started. X-ray generation and medical application will be performed in the early next year.

  1. Analysis of magnetically immersed electron guns with non-adiabatic fields.

    PubMed

    Pikin, Alexander; Alessi, James G; Beebe, Edward N; Raparia, Deepak; Ritter, John

    2016-11-01

    Electron diode guns, which have strongly varying magnetic or electric fields in a cathode-anode gap, were investigated in order to generate laminar electron beams with high current density using magnetically immersed guns. By creating a strongly varying radial electric field in a cathode-anode gap of the electron gun, it was demonstrated that the optical properties of the gun can be significantly altered, which allows the generation of a laminar, high-current electron beam with relatively low magnetic field on the cathode. The relatively high magnetic compression of the electron beam achieved by this method is important for producing electron beams with high current density. A similar result can be obtained by inducing a strong variation of the magnetic field in a cathode-anode gap. It was observed that creating a dip in the axial magnetic field in the cathode-anode gap of an adiabatic electron gun has an optical effect similar to guns with strong variation of radial electric field. By analyzing the electron trajectories angles and presenting the results in a gun performance map, different geometries of magnetically immersed electron guns with non-adiabatic fields are compared with each other and with a more traditional adiabatic electron gun. Some advantages and limitations of guns with non-adiabatic fields are outlined. The tests' results of a non-adiabatic electron gun with modified magnetic field are presented.

  2. Utility of indices of gun availability in the community.

    PubMed

    Shenassa, Edmond D; Daskalakis, Constantine; Buka, Stephen L

    2006-01-01

    To estimate the degree to which the proportion of homicides and suicides committed with a gun is associated with reported availability of firearms across Chicago neighbourhoods. Data were collected as part of the Project on Human Development in Chicago Neighborhoods (PHDCN), a combined neighbourhood and individual level study of the city of Chicago. The study used data from 837 PHDCN participants between the ages of 17 and 22, residing in 170 different neighbourhoods. Gun availability was measured via participant reports on whether they had carried a gun and whether they perceived gun access to be easy in their community. Data on suicides and homicides were obtained from the Chicago Department of Health. A 10% change in the proportion of homicides committed by a gun in a neighbourhood was associated with a 20% increase in both the odds of reported gun access and reported gun carrying (p=0.002 and 0.048, respectively). The proportion of firearm related suicides was not associated with either of those self reported measures. The proportion of firearm related homicides, but not the proportion of firearm related suicides, is a useful predictor of gun availability across small areas such as neighbourhoods.

  3. Reduction of Salmonella on alfalfa seeds using peroxyacetic acid and a commercial seed washer is as effective as treatment with 20 000 ppm of Ca(OCl)2.

    PubMed

    Buchholz, A; Matthews, K R

    2010-10-01

    The efficacy of a commercial seed washer and 1 and 3% peroxyacetic acid or 20 000 ppm calcium hypochlorite for reducing Salmonella on alfalfa seeds was investigated. Alfalfa seeds were inoculated with Salmonella Stanley to achieve c. 5 log CFU g(-1). Seeds were then treated with 1 or 3% peroxyacetic acid or 20 000 ppm calcium hypochlorite for 15 min in a commercial seed washer that uses air to enhance contact of the sanitizer with the seed. Experiments were also conducted using industry and laboratory methods. An c. 1-log reduction in number of Salm. Stanley was demonstrated regardless of the chemical treatment or method of treatment. Although this 1-log reduction was significant (P < 0.05), differences among the treatments were not significant. Treating the seed with 1 and 3% peroxyacetic acid resulted in similar Salm. Stanley reductions of 1.77 and 1.34 log, respectively, not being statistically significant (P > 0.05). These results suggest that under conditions tested, 1 or 3% peroxyacetic acid solutions are equally effective as 20 000 ppm of Ca(OCl)2 in the reduction of Salm. Stanley on alfalfa seed when used in conjunction with a commercial seed washer. A 1% peroxyacetic acid solution could potentially be used in place of 20 000 ppm of Ca(OCl)2 for treatment of seeds used for sprouting. The commercial seed washer did not enhance removal of Salm. Stanley from alfalfa seeds, but did facilitate removal of excess soil from seeds. © 2010 The Authors. Journal compilation © 2010 The Society for Applied Microbiology.

  4. Physicians Asking Patients About Guns: Promoting Patient Safety, Respecting Patient Rights.

    PubMed

    Parent, Brendan

    2016-10-01

    Recent debate on whether physicians should discuss gun ownership with their patients has centered on determining whether gun injuries are an issue of health or safety, and on protecting patient privacy. Yet, physicians' duties span personal health, public health, and safety spheres, and they often must address private patient matters. To prioritize gun safety and reduce gun injuries, the primary policy-driving question should be: will physician counseling on gun ownership effectively reduce gun-related injuries without interfering with the physician's other treatment obligations or compromising the physician-patient relationship? Existing data on physician-initiated conversations with patients about guns support a positive prevention effect. However, it is critical that physician-initiated discussions of safe gun practices are not motivated by, nor convey, disapproval of gun ownership. To be ethical, respectful, and efficient, the conversation should be standard between primary care providers and all of their patients (not limited to patient subsets); questions and education should be limited to topics of gun-ownership risks and storage practices; and the conversation must be framed without bias against gun ownership.

  5. Gun buyback programs: a venue to eliminate unwanted guns in the community.

    PubMed

    Violano, Pina; Driscoll, Cassandra; Chaudhary, Neil K; Schuster, Kevin M; Davis, Kimberly A; Borer, Esther; Winters, Jane K; Hirsh, Michael P

    2014-09-01

    The United States has a high rate of death due to firearms, and gun buyback programs may mitigate these high death rates. Understanding the demographics, motivation, and geographic region of participants may improve program efficacy. Three Injury Free Coalition for Kids gun buyback programs, in collaboration with the local police, were studied: Phoenix, Arizona; Worcester, Massachusetts; and New Haven, Connecticut. Participants were defined as those who relinquished a firearm. A self-administered, anonymous, paper survey elicited information from participants regarding demographic data, formal training on the use of the firearm, how the firearm was acquired, potential child access, knowledge of others injured by a firearm, whether the firearm was stored unlocked, factors motivating the surrender of the firearm, and other factors. Survey results were entered into a composite database and analyzed for differences in location, race, sex, and other factors. Participants (n = 301) were predominantly male (73.5%), white (80.9%), and older than 55 years (59.0%). They lived an average of 19.0 miles from the event by zip codes and had an average median household income of $65,731. More than half (54.5%) did not purchase the firearm, acquiring it through inheritance, gift, or random find. Most (74.8%) had previous firearms training and were relinquishing for safety reasons (68.3%). Those relinquishing firearms for safety reasons were less likely to have purchased the firearm (odds ratio [OR], 2.46, p <0.05), less likely to have any formal training (OR, 5.92; p < 0.01), and less likely to keep the firearm locked (OR, 3.50; p < 0.01). Women were less likely to have purchased the firearm (OR, 0.50; p < 0.05). Fifty-three percent of those turning in firearms reported having at least one more firearm at home; designated themselves to be white, compared with all other groups combined (OR, 2.55; p < 0.05); more likely to report locking the firearm (OR, 0.11; p < 0.001); more

  6. Should gun safety be taught in schools? Perspectives of teachers.

    PubMed

    Obeng, Cecilia

    2010-08-01

    Gun-related injuries and deaths among children occur at disproportionately high rates in the United States. Children who live in homes with guns are the most likely victims. This study describes teachers' views on whether gun safety should be taught to children in the preschool and elementary years. A total of 150 survey questionnaires were distributed to public and private school teachers in preschools and elementary schools in 2 counties of a Midwestern state. In total, 62% of the 102 respondents indicated that they favored the teaching of gun safety, while 13% disapproved and 25% had no opinion. Overall, 28.4% of the respondents supported the teaching of gun safety in grades pre-K (pre-kindergarten) through first grade. About 54% indicated that police or trained military personnel should do the teaching of this subject in schools, while 6.9% suggested that teachers should do the teaching. With a majority of the teachers in favor of teaching gun safety in the schools, a larger study should be conducted that explores the introduction of gun safety into the curriculum in preschool through grade 6. Such a study should evaluate the efficacy of teaching gun safety as a measure to prevent gun violence and injuries involving guns.

  7. In-state and interstate associations between gun shows and firearm deaths and injuries: A quasi-experimental study

    PubMed Central

    Matthay, Ellicott C.; Galin, Jessica; Rudolph, Kara E.; Farkas, Kriszta; Wintemute, Garen; Ahern, Jennifer

    2018-01-01

    Background Gun shows are an important source of firearms, but no adequately powered studies have examined whether these events are associated with increases in firearm injuries. Objective To determine whether gun shows are associated with short-term increases in locally occurring firearm injuries and whether this association differs by the state in which the gun show occurs. Design Quasi-experimental. Setting California. Study Population Individuals in California within driving distance of gun shows. Measurements Gun shows in California and Nevada between 2005 and 2013 (n = 915 shows) and rates of firearm-related deaths, emergency department visits, and inpatient hospitalizations in California. Results Compared to the two weeks before gun shows occurred, post-show firearm injury rates remained stable in regions near California gun shows but increased from 0.67 (95% CI, 0.55 to 0.80) to 1.14 (95% CI, 0.97 to 1.30) per 100,000 in regions near Nevada shows. After adjustment for seasonality and clustering, California shows were not associated with increases in local firearm injuries (RR, 0.99 [95% CI, 0.97 to 1.02]), but Nevada shows were associated with increases in injuries occurring in California (RR, 1.69 [95% CI, 1.16 to 2.45]). The pre-post difference was significantly higher for Nevada shows compared to California shows (Ratio of RRs, 1.70 [95% CI, 1.17 to 2.47]). The Nevada association was driven by significant increases in interpersonal violence firearm injuries (RR, 2.23 [95% CI, 1.01 to 4.89), but corresponded to a small increase in absolute numbers. Non-firearm injuries served as a negative control and were not associated with California or Nevada gun shows. Results were robust to sensitivity analyses. Limitation We only examined firearm injuries in California, and gun show occurrence was not randomized. Conclusion Gun shows occurring in Nevada, but not California, are associated with local, short-term increases in firearm injuries in California. Differing

  8. Note: design and development of improved indirectly heated cathode based strip electron gun.

    PubMed

    Maiti, Namita; Bade, Abhijeet; Tembhare, G U; Patil, D S; Dasgupta, K

    2015-02-01

    An improved design of indirectly heated solid cathode based electron gun (200 kW, 45 kV, 270° bent strip type electron gun) has been presented. The solid cathode is made of thoriated tungsten, which acts as an improved source of electron at lower temperature. So, high power operation is possible without affecting structural integrity of the electron gun. The design issues are addressed based on the uniformity of temperature on the solid cathode and the single long filament based design. The design approach consists of simulation followed by extensive experimentation. In the design, the effort has been put to tailor the non-uniformity of the heat flux from the filament to the solid cathode to obtain better uniformity of temperature on the solid cathode. Trial beam experiments have been carried out and it is seen that the modified design achieves one to one correspondence of the solid cathode length and the electron beam length.

  9. Note: Design and development of improved indirectly heated cathode based strip electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maiti, Namita; Patil, D. S.; Dasgupta, K.

    An improved design of indirectly heated solid cathode based electron gun (200 kW, 45 kV, 270° bent strip type electron gun) has been presented. The solid cathode is made of thoriated tungsten, which acts as an improved source of electron at lower temperature. So, high power operation is possible without affecting structural integrity of the electron gun. The design issues are addressed based on the uniformity of temperature on the solid cathode and the single long filament based design. The design approach consists of simulation followed by extensive experimentation. In the design, the effort has been put to tailor themore » non-uniformity of the heat flux from the filament to the solid cathode to obtain better uniformity of temperature on the solid cathode. Trial beam experiments have been carried out and it is seen that the modified design achieves one to one correspondence of the solid cathode length and the electron beam length.« less

  10. High current polarized electron source for future eRHIC

    NASA Astrophysics Data System (ADS)

    Wang, Erdong

    2018-05-01

    The high current and high bunch charge polarized electron source is essential for cost reduction of Linac-Ring (L-R) eRHIC. In the baseline design, electron beam from multiple guns (probably 4-8) will be combined using deflection plates or accumulate ring. Each gun aims to deliver electron beam with 10 mA average current and 5.3 nC bunch charge. With total 50 mA and 5.3 nC electron beam, this beam combining design could use for generating positron too. The gun has been designed, fabricated and expected to start commissioning by the mid of this year. In this paper, we will present the DC gun design parameters and beam combine schemes. Also, we will describe the details of gun design and the strategies to demonstrate high current high charge polarized electron beam from this source.

  11. Engineering design of the PLX- α coaxial gun

    NASA Astrophysics Data System (ADS)

    Cruz, Edward; Brockington, Samuel; Case, Andrew; Luna, Marco; Witherspoon, Douglas; Langendorf, Samuel

    2016-10-01

    We describe the engineering and technical aspects of the coaxial gun designed for the 60-gun scaling study of spherically imploding plasma liners as a standoff driver for plasma-jet-driven magneto-inertial fusion. Each coaxial gun incorporates a fast, dense gas injection and triggering system, a compact low-weight pfn with integral sparkgap switching, and a contoured gap designed to suppress the blow-by instability. Alpha1 and Alpha2 guns are compared, with emphasis on the improvements on Alpha2, which include a faster more robust gas valve, an improved electrode contour, a custom 600- μF, 5-kV pfn, and a set of six inline sparkgap switches operated in parallel. The switch and pfn configurations are mounted directly to the back of the gun, and are designed to reduce inductance, cost, and complexity, maximize efficiency and system reliability, and ensure symmetric current flow. We will provide a detailed overview of the design choices made for the PLX- α coaxial gun. This work supported by the ARPA-E ALPHA Program.

  12. Analysis of magnetically immersed electron guns with non-adiabatic fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pikin, Alexander; Alessi, James G.; Beebe, Edward N.

    Electron diode guns, which have strongly varying magnetic or electric fields in a cathode-anode gap, were investigated in order to generate laminar electron beams with high current density using magnetically immersed guns. By creating a strongly varying radial electric field in a cathode-anode gap of the electron gun, it was demonstrated that the optical properties of the gun can be significantly altered, which allows the generation of a laminar, high-current electron beam with relatively low magnetic field on the cathode. The relatively high magnetic compression of the electron beam achieved by this method is important for producing electron beams withmore » high current density. A similar result can be obtained by inducing a strong variation of the magnetic field in a cathode-anode gap. It was observed that creating a dip in the axial magnetic field in the cathode-anode gap of an adiabatic electron gun has an optical effect similar to guns with strong variation of radial electric field. By analyzing the electron trajectories angles and presenting the results in a gun performance map different geometries of magnetically immersed electron guns with non-adiabatic fields are compared with each other and with a more traditional adiabatic electron gun. Some advantages and limitations of guns with non-adiabatic fields are outlined. In conclusion, the tests results of non-adiabatic electron gun with modified magnetic field are presented.« less

  13. Analysis of magnetically immersed electron guns with non-adiabatic fields

    DOE PAGES

    Pikin, Alexander; Alessi, James G.; Beebe, Edward N.; ...

    2016-11-08

    Electron diode guns, which have strongly varying magnetic or electric fields in a cathode-anode gap, were investigated in order to generate laminar electron beams with high current density using magnetically immersed guns. By creating a strongly varying radial electric field in a cathode-anode gap of the electron gun, it was demonstrated that the optical properties of the gun can be significantly altered, which allows the generation of a laminar, high-current electron beam with relatively low magnetic field on the cathode. The relatively high magnetic compression of the electron beam achieved by this method is important for producing electron beams withmore » high current density. A similar result can be obtained by inducing a strong variation of the magnetic field in a cathode-anode gap. It was observed that creating a dip in the axial magnetic field in the cathode-anode gap of an adiabatic electron gun has an optical effect similar to guns with strong variation of radial electric field. By analyzing the electron trajectories angles and presenting the results in a gun performance map different geometries of magnetically immersed electron guns with non-adiabatic fields are compared with each other and with a more traditional adiabatic electron gun. Some advantages and limitations of guns with non-adiabatic fields are outlined. In conclusion, the tests results of non-adiabatic electron gun with modified magnetic field are presented.« less

  14. [Significance of working environment improvement based on determination of source of harmful substance--example of an endoscope syringe room using glutaraldehyde].

    PubMed

    Tashiro, Hiraku; Oda, Susumu; Mori, Koji

    2004-03-01

    Because a worker complained of irritated eyes and throat due to glutaraldehyde (GA) in an endoscope syringe room, the automated endoscope washers and GA liquid stored in reserve were isolated in a separate room. A ventilation system was installed in this room, and the packing of the automated endoscope washers was changed. However, since the obnoxious smell of GA still remained in the endoscope syringe room, we had to determine the source of the smell. A plastic bucket with a cap was found to be filled with GA for disinfection of the endoscope apparatus. GA had evaporated when dispersed around the bucket, resulting in the obnoxious smell. The plastic bucket was replaced with a different type of container. Moreover, GA from the separate room did not affect the concentration of GA in the working area because the separate room for the automated endoscope washers had twice the ventilation volume proposed by the guidelines of the Society of Gastroenterology Nurses and Associates of the USA and the Healthcare Engineering Association of Japan. Consequently, we reconfirmed the significance of working environment improvement after clarifying the source of the harmful substance.

  15. Model for intensity calculation in electron guns

    NASA Astrophysics Data System (ADS)

    Doyen, O.; De Conto, J. M.; Garnier, J. P.; Lefort, M.; Richard, N.

    2007-04-01

    The calculation of the current in an electron gun structure is one of the main investigations involved in the electron gun physics understanding. In particular, various simulation codes exist but often present some important discrepancies with experiments. Moreover, those differences cannot be reduced because of the lack of physical information in these codes. We present a simple physical three-dimensional model, valid for all kinds of gun geometries. This model presents a better precision than all the other simulation codes and models encountered and allows the real understanding of the electron gun physics. It is based only on the calculation of the Laplace electric field at the cathode, the use of the classical Child-Langmuir's current density, and a geometrical correction to this law. Finally, the intensity versus voltage characteristic curve can be precisely described with only a few physical parameters. Indeed, we have showed that only the shape of the electric field at the cathode without beam, and a distance of an equivalent infinite planar diode gap, govern mainly the electron gun current generation.

  16. Utility of indices of gun availability in the community

    PubMed Central

    Shenassa, Edmond D; Daskalakis, Constantine; Buka, Stephen L

    2006-01-01

    Objective To estimate the degree to which the proportion of homicides and suicides committed with a gun is associated with reported availability of firearms across Chicago neighbourhoods. Methods Data were collected as part of the Project on Human Development in Chicago Neighborhoods (PHDCN), a combined neighbourhood and individual level study of the city of Chicago. The study used data from 837 PHDCN participants between the ages of 17 and 22, residing in 170 different neighbourhoods. Gun availability was measured via participant reports on whether they had carried a gun and whether they perceived gun access to be easy in their community. Data on suicides and homicides were obtained from the Chicago Department of Health. Results A 10% change in the proportion of homicides committed by a gun in a neighbourhood was associated with a 20% increase in both the odds of reported gun access and reported gun carrying (p = 0.002 and 0.048, respectively). The proportion of firearm related suicides was not associated with either of those self reported measures. Conclusions The proportion of firearm related homicides, but not the proportion of firearm related suicides, is a useful predictor of gun availability across small areas such as neighbourhoods. PMID:16401610

  17. Experiments and Demonstrations with Soldering Guns.

    ERIC Educational Resources Information Center

    Henry, Dennis C.; Danielson, Sarah A.

    1993-01-01

    Discusses the essential electrical characteristics of a particular model of soldering gun. Presents four classroom demonstrations that utilize the soldering gun to test the following geometrics of wire loops as electromagnets: (1) the original tip; (2) a single circular loop; (3) a Helmholtz coil; and (4) the solenoid. (MDH)

  18. Simulations of Gaussian electron guns for RHIC electron lens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pikin, A.

    Simulations of two versions of the electron gun for RHIC electron lens are presented. The electron guns have to generate an electron beam with Gaussian radial profile of the electron beam density. To achieve the Gaussian electron emission profile on the cathode we used a combination of the gun electrodes and shaping of the cathode surface. Dependence of electron gun performance parameters on the geometry of electrodes and the margins for electrodes positioning are presented.

  19. Modeling internal ballistics of gas combustion guns.

    PubMed

    Schorge, Volker; Grossjohann, Rico; Schönekess, Holger C; Herbst, Jörg; Bockholdt, Britta; Ekkernkamp, Axel; Frank, Matthias

    2016-05-01

    Potato guns are popular homemade guns which work on the principle of gas combustion. They are usually constructed for recreational rather than criminal purposes. Yet some serious injuries and fatalities due to these guns are reported. As information on the internal ballistics of homemade gas combustion-powered guns is scarce, it is the aim of this work to provide an experimental model of the internal ballistics of these devices and to investigate their basic physical parameters. A gas combustion gun was constructed with a steel tube as the main component. Gas/air mixtures of acetylene, hydrogen, and ethylene were used as propellants for discharging a 46-mm caliber test projectile. Gas pressure in the combustion chamber was captured with a piezoelectric pressure sensor. Projectile velocity was measured with a ballistic speed measurement system. The maximum gas pressure, the maximum rate of pressure rise, the time parameters of the pressure curve, and the velocity and path of the projectile through the barrel as a function of time were determined according to the pressure-time curve. The maximum gas pressure was measured to be between 1.4 bar (ethylene) and 4.5 bar (acetylene). The highest maximum rate of pressure rise was determined for hydrogen at (dp/dt)max = 607 bar/s. The muzzle energy was calculated to be between 67 J (ethylene) and 204 J (acetylene). To conclude, this work provides basic information on the internal ballistics of homemade gas combustion guns. The risk of injury to the operator or bystanders is high, because accidental explosions of the gun due to the high-pressure rise during combustion of the gas/air mixture may occur.

  20. Gun Carrying by High School Students in Boston, MA: Does Overestimation of Peer Gun Carrying Matter?

    ERIC Educational Resources Information Center

    Hemenway, David; Vriniotis, Mary; Johnson, Renee M.; Miller, Matthew; Azrael, Deborah

    2011-01-01

    This paper investigates: (1) whether high school students overestimate gun carrying by their peers, and (2) whether those students who overestimate peer gun carrying are more likely to carry firearms. Data come from a randomly sampled survey conducted in 2008 of over 1700 high school students in Boston, MA. Over 5% of students reported carrying a…

  1. Research on vibration characteristics of gun barrel based on contact model

    NASA Astrophysics Data System (ADS)

    Zhao, Yang; Zhou, Qizheng; Yue, Pengfei

    2017-04-01

    In order to study vibration characteristics of the gun barrel under the action of moving projectile, the gun barrel is simplified to cross sectional cantilever beam such as Euler. Considering contact conditions of inertia effect and projectile with the gun barrel, the equation of lateral vibration of the gun barrel is established under the projectile-gun coupling effect; the modal analysis method is used to give the analytic solutions of equation series. The effect of the motion parameters the projectile on the vibration of gun barrel is discussed, and characteristics of vibration of gun barrel are further studied under two conditions of repeating and projectile with mass eccentricity. The research results show that reasonable control of the acceleration of the projectile in the gun bore, and reduction of projectile mass eccentricity can help reduce the muzzle vibration at the gun firing. The research results can provide reference for overall design of the gun, and the modeling and analysis method used in the paper can be promoted for the solution of vibration of other related projects under the moving excitation.

  2. The PLX- α Plasma Guns: Progress and Plans

    NASA Astrophysics Data System (ADS)

    Witherspoon, F. D.; Brockington, S.; Case, A.; Cruz, E.; Luna, M.; Thio, Y. C. Francis; LANL PLX-α Team

    2017-10-01

    The ALPHA coaxial plasma guns are being developed to support a 60-gun scaling study of spherically imploding plasma liners as a standoff driver for plasma-jet-driven magneto-inertial fusion (PJMIF). Seven complete guns have been delivered to LANL with 6 guns currently undergoing simultaneous test firings on PLX. The guns are designed to operate over a range of parameters: 0.5-5.0 mg of Ar, Ne, N2, Kr, and Xe; 20-60 km/s; 2 × 1016 cm-3 muzzle density; and up to 7.5 kJ stored energy per gun. Each coaxial gun incorporates a fast dense gas injection and triggering system, a compact low-weight pfn with integral sparkgap switching, and a contoured coaxial gap to suppress the blow-by instability. Optimizing parameter scans performed at HyperV have achieved : 4 mg at >50 km/s and length of 10 cm. Peak axial density 30 cm from the muzzle is 2 ×1016 cm-3. We will provide an overview of the experimental results, along with plans for further improvements in reliability, maintainability, fabricability, and plasma jet performance, with the latter focused on further improvements in the fast gas valve and the ignitors. This work supported by the ARPA-E ALPHA Program under contract DE-AR0000566 and Strong Atomics, LLC.

  3. Quantum efficiency temporal response and lifetime of a GaAs cathode in SRF electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, E.; Ben-Zvi, I.; Kewisch, J.

    2010-05-23

    RF electron guns with a strained super lattice GaAs cathode can generate polarized electron beam of higher brightness and lower emittance than do DC guns, due to their higher field gradient at the cathode's surface. In a normal conducting RF gun, the extremely high vaccum required by these cathodes can not be met. We report on an experiment with a superconducting SRF gun, which can maintain a vacuum of nearly 10-12 torr because of cryo-pumping at the temperature of 4.2K. With conventional activation, we obtained a QE of 3% at 532 nm, with lifetime of nearly 3 days in themore » preparation chamber. We plan to use this cathode in a 1.3 GHz 1/2 cell SRF gun to study its performance. In addition, we studied the multipacting at the location of cathode. A new model based on the Forkker-Planck equation which can estimate the bunch length of the electron beam is discussed in this paper. Future particle accelerators such as eRHIC and ILC require high brightness, high current polarized electrons Recently, using a superlattice crystal, the maximum polarization of 95% was reached. Activation with Cs,O lowers the electron affinity and makes it energetically possible for all the electrons excited in to the conduction band and reach the surface to escape into the vacuum. Presently the polarized electron sources are based on DC gun, such as that at the CEBAF at Jlab. In these devices, the life time of the cathode is extended due to the reduced back bombardment in their UHV conditions. However, the low accelerating gradient of the DC guns lead to poor longitudinal emittance. The higher accelerating gradient of the RF gun generates low emittance beams. Superconducting RF guns combine the excellent vacuum conditions of the DC guns with the higher accelerating gradients of the RF guns and provide potentially a long lived cathode with very low transverse and longitudinal emittance. In our work at BNL, we successfully activated the GaAs. The quantum efficient is 3% at 532 nm and is

  4. Development of plasma cathode electron guns

    NASA Astrophysics Data System (ADS)

    Oks, Efim M.; Schanin, Peter M.

    1999-05-01

    The status of experimental research and ongoing development of plasma cathode electron guns in recent years is reviewed, including some novel upgrades and applications to various technological fields. The attractiveness of this kind of e-gun is due to its capability of creating high current, broad or focused beams, both in pulsed and steady-state modes of operation. An important characteristic of the plasma cathode electron gun is the absence of a thermionic cathode, a feature which leads to long lifetime and reliable operation even in the presence of aggressive background gas media and at fore-vacuum gas pressure ranges such as achieved by mechanical pumps. Depending on the required beam parameters, different kinds of plasma discharge systems can be used in plasma cathode electron guns, such as vacuum arcs, constricted gaseous arcs, hollow cathode glows, and two kinds of discharges in crossed E×B fields: Penning and magnetron. At the present time, plasma cathode electron guns provide beams with transverse dimension from fractional millimeter up to about one meter, beam current from microamperes to kiloamperes, beam current density up to about 100 A/cm2, pulse duration from nanoseconds to dc, and electron energy from several keV to hundreds of keV. Applications include electron beam melting and welding, surface treatment, plasma chemistry, radiation technologies, laser pumping, microwave generation, and more.

  5. Optimization of a two stage light gas gun. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Rynearson, R. J.; Rand, J. L.

    1972-01-01

    Performance characteristics of the Texas A&M University light gas gun are presented along with a review of basic gun theory and popular prediction methods. A computer routine based on the simple isentropic compression method is discussed. Results from over 60 test shots are given which demonstrate an increase in gun muzzle velocity from 9.100 ft/sec. to 19,000 ft/sec. The data gathered indicated the Texas A&M light gas gun more closely resembles an isentropic compression gun rather than a shock compression gun.

  6. Accidental Bolt Gun Injury to Femur - A Case Report.

    PubMed

    Kattimani, Ravi Prasad; Shetty, Sanath; Mirza, Humayun

    2016-01-01

    Bolt gun or slaughterer's guns are used in meat industry for "humane killing" of animals. Injuries caused by bolt gun are rare, reported exclusively from central European countries. We report a case of 28 year old male, who accidentally shot himself with a bolt gun to his right thigh. A 28 years old male presented to our Accident and Emergency department after accidental injury to his right thigh with bolt gun. He had an entry wound measuring 2 cm in length and 1 cm in breadth over anterior aspect of lower one third of thigh at lower and sustained Grade II compound fracture of right femur shaft at distal one third. The wound was treated with multiple debridements, negative pressure wound therapy and intravenous antibiotics based on culture and sensitivity. Bolt gun or slaughterer's guns are weapons used in meat industry for slaughtering animals. Wounds inflicted by bolt guns have specific morphological feature, distinctive from wounds made by other kinds of hand firearms. Most of the time wound will be infected at presentation. Lesions caused by these weapons are likely to have a more serious character than is to be expected from the size of the entrance wound. The mainstay of treatment is liberal wound exploration, multiple debridement's and intra venous antibiotics based on culture reports to treat infection and prevent morbidity.

  7. Characteristics of a gun exchange program, and an assessment of potential benefits

    PubMed Central

    Romero, M.; Wintemute, G.; Vernick, J.

    1998-01-01

    Objectives—To describe a gun exchange program and assess potential benefits for participants and host communities. Methods—Mail survey of participants in a Sacramento, California gun exchange program, August 1993; the response rate was 79%. Comparative data were obtained from nationwide polls of gun owners. Results—Most (62%) respondents were men; 40% were more than 55 years old; none was less than 25. Concern that children might find and use the gun was the most frequently cited reason for participating (46% of respondents). Of 141 firearms exchanged, 72% were handguns; 23% of respondents indicated that the guns they turned in were not in working order. Of respondents who owned a gun at the time of the program (rather than those who owned no guns and turned in a gun owned by someone else), 41% owned no guns after participating; the prevalence of handgun ownership declined from 79% to 32%. Those who continued to own guns were as likely as gun owners nationwide to keep a gun loaded in the house (odds ratio (OR) 0.9, 95% confidence interval (CI) 0.4 to 1.7) or to carry a gun with them (OR 1.5, 95% CI 0.6 to 3.8). Conclusions—Gun exchange programs may reduce risk for firearm violence among some participants, but a number of factors limit their overall benefits to host communities. PMID:9788092

  8. In-State and Interstate Associations Between Gun Shows and Firearm Deaths and Injuries: A Quasi-experimental Study.

    PubMed

    Matthay, Ellicott C; Galin, Jessica; Rudolph, Kara E; Farkas, Kriszta; Wintemute, Garen J; Ahern, Jennifer

    2017-12-19

    Gun shows are an important source of firearms, but no adequately powered studies have examined whether they are associated with increases in firearm injuries. To determine whether gun shows are associated with short-term increases in local firearm injuries and whether this association differs by the state in which the gun show is held. Quasi-experimental. California. Persons in California within driving distance of gun shows. Gun shows in California and Nevada between 2005 and 2013 (n = 915 shows) and rates of firearm-related deaths, emergency department visits, and inpatient hospitalizations in California. Compared with the 2 weeks before, postshow firearm injury rates remained stable in regions near California gun shows but increased from 0.67 injuries (95% CI, 0.55 to 0.80 injuries) to 1.14 injuries (CI, 0.97 to 1.30 injuries) per 100 000 persons in regions near Nevada shows. After adjustment for seasonality and clustering, California shows were not associated with increases in local firearm injuries (rate ratio [RR], 0.99 [CI, 0.97 to 1.02]) but Nevada shows were associated with increased injuries in California (RR, 1.69 [CI, 1.16 to 2.45]). The pre-post difference was significantly higher for Nevada shows than California shows (ratio of RRs, 1.70 [CI, 1.17 to 2.47]). The Nevada association was driven by significant increases in firearm injuries from interpersonal violence (RR, 2.23 [CI, 1.01 to 4.89]) but corresponded to a small increase in absolute numbers. Nonfirearm injuries served as a negative control and were not associated with California or Nevada gun shows. Results were robust to sensitivity analyses. Firearm injuries were examined only in California, and gun show occurrence was not randomized. Gun shows in Nevada, but not California, were associated with local, short-term increases in firearm injuries in California. Differing associations for California versus Nevada gun shows may be due to California's stricter firearm regulations. National

  9. Gun violence in Americans' social network during their lifetime.

    PubMed

    Kalesan, Bindu; Weinberg, Janice; Galea, Sandro

    2016-12-01

    The overall burden of gun violence death and injury in the US is now well understood. However, no study has shown the extent to which gun violence is associated with the individual lives of Americans. We used fatal and non-fatal gun injury rates in 2013 from Centers for Disease Control and Prevention's Web-based Injury Statistics Query and Reporting System (WISQARS) and generally accepted estimates about the size of an American's social network to determine the likelihood that any given person will know someone in their personal social network who is a victim of gun violence during their lifetime. We derived estimates in the overall population and among racial/ethnic groups and by gun-injury intent. The likelihood of knowing a gun violence victim within any given personal network over a lifetime is 99.85% (99.8% to 99.9%). The likelihood among non-Hispanic white, black, Hispanic and other race Americans were 97.1%, 99.9%, 99.5% and 88.9% respectively. Nearly all Americans of all racial/ethnic groups are likely to know a victim of gun violence in their social network during their lifetime. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Modeling electron beam parameters and plasma interface position in an anode plasma electron gun with hydrogen atmosphere

    NASA Astrophysics Data System (ADS)

    Krauze, A.; Virbulis, J.; Kravtsov, A.

    2018-05-01

    A beam glow discharge based electron gun can be applied as heater for silicon crystal growth systems in which silicon rods are pulled from melt. Impacts of high-energy charged particles cause wear and tear of the gun and generate an additional source of silicon contamination. A steady-state model for electron beam formation has been developed to model the electron gun and optimize its design. Description of the model and first simulation results are presented. It has been shown that the model can simulate dimensions of particle impact areas on the cathode and anode, but further improvements of the model are needed to correctly simulate electron trajectory distribution in the beam and the beam current dependence on the applied gas pressure.

  11. Construction of a Simple, Inexpensive Multiple Enzyme-Linked Immunosorbent Assay Microdilution Plate Washer

    PubMed Central

    Stobbs, L. W.

    1990-01-01

    In this paper, plans are given for the construction of an inexpensive enzyme-linked immunosorbent assay plate washer from readily available materials. The wash unit uses an intermittent wash cycle based on a wash manifold cycling over the microdilution plates for a predetermined time. Laboratory tests showed that the unit provided reliable, rapid washing of plates with tap water, with no detectable contamination between wells. Substrate absorbance values for test samples from machine-washed plates were equal to or greater than absorbance values for corresponding samples from plates washed manually by an accepted protocol, by using either enzyme-linked immunosorbent assay wash buffer or tap water. Images PMID:16348216

  12. NPS Gas Gun for Planar Impact Studies

    NASA Astrophysics Data System (ADS)

    Cheong Ho, Chien; Hixson, Robert

    2009-11-01

    The Naval Postgraduate School (NPS) commissioned a Gas Gun for shock wave studies on 9^th October 2009, by performing the first experiment. The Gas Gun is the key element of NPS Shock Wave Research Program within the Physics Department, where well-characterized planar impacts are essential for obtaining high quality data, to characterize a solid material. This first experiment was very successful, and returned key data on the quality of the impact conditions created. The Gas Gun is designed by SANDIA NATIONAL LABORATORIES, and the NPS spent twelve months fabricating the components of the Gas Gun and six months assembling the Gas Gun. Three inch projectile are launched at velocities up to 0.5 km/s, creating high pressure and temperature states that can be used to characterize the fundamental response of relevant materials to dynamic loading. The projectile is launched from a `wrap around' gas breech where helium gas is pressurized to relatively low pressure. This gas is used to accelerate the projectile down a 3m barrel. Upon impact, the speed of the projectile and the flatness of the impact is measured, via a stepped circular pin array circuit. The next stage of development for the Gas Gun is to integrate a Velocity Interferometer System for Any Reflector (VISAR). The VISAR sees all the waves that flow through the target plate as a result of the impact. This is a key diagnostic for determining material properties under dynamic loading conditions.

  13. Handgun waiting periods reduce gun deaths

    PubMed Central

    Luca, Michael; Malhotra, Deepak

    2017-01-01

    Handgun waiting periods are laws that impose a delay between the initiation of a purchase and final acquisition of a firearm. We show that waiting periods, which create a “cooling off” period among buyers, significantly reduce the incidence of gun violence. We estimate the impact of waiting periods on gun deaths, exploiting all changes to state-level policies in the Unites States since 1970. We find that waiting periods reduce gun homicides by roughly 17%. We provide further support for the causal impact of waiting periods on homicides by exploiting a natural experiment resulting from a federal law in 1994 that imposed a temporary waiting period on a subset of states. PMID:29078268

  14. Law enforcement officers' opinions about gun locks: anchors on life jackets?

    PubMed Central

    Coyne-Beasley, T; Johnson, R

    2001-01-01

    Objectives—One way law enforcement officers support firearm safety is by promoting the use of gun locks. This investigation examined law enforcement officers' willingness to use gun locks on their own guns, as well as their opinions regarding gun locks in general. Setting—Law enforcement officers from an urban agency in the southern region of the United States. Methods—Free keyed cable gun locks were distributed to all law enforcement officers in one agency who wanted one, and then an anonymous questionnaire survey was conducted about their subsequent use of, and attitudes toward, these devices. Results—About half of the 207 officers collected gun locks (n=103). Nearly three quarters (73%) completed and returned the questionnaire. Two thirds reported that they were not using the gun lock they collected (65%), and over half disagreed that gun lock use should be required (56%). Very few cited any actual or potential technical problems with the device. An important reason given for non-use of gun locks related to being able to access the weapon quickly in case of an emergency. Conclusions—The findings highlight the need for further investigation into law enforcement officers' attitudes toward gun locks, the degree to which their attitudes affect their firearm safety counseling, and the need to develop a gun safety device that can be disengaged quickly. PMID:11565984

  15. ONEGUN: an interior ballistics code for closed breech guns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reis, G.E.

    1982-07-01

    This program computes the gun and projectile motion and the gas thermodynamic properties (the internal ballistics) of a closed breech gun. Heat losses and friction losses are taken into account. A dual grain charge can be used. The inputs required are the usual propellant characteristics (density, impetus, gamma, burn rate coefficient and exponent, grain geometry, covolume and isochoric flame temperature). The gun characteristics (chamber volume and length, rifle twist rate, bore diameter, gun weight and start pressure) and the projectile characteristics (projectile weight, radius of gyration and start pressure). The output consists of the motion (displacement, velocity, and acceleration) ofmore » both the projectile and the recoiling gun and the gas pressures and temperature, all as a function of time.« less

  16. Youth Homicide and Guns. Firearm Facts.

    ERIC Educational Resources Information Center

    Duker, Laurie, Ed.

    Young Americans are killed with guns at rates far higher than young people in other countries and than older Americans, with young, urban African-American males being most at risk. This fact sheet presents data on gun-related homicides among teenagers in the United States. The high rate of youth homicide in the United States is unique in the…

  17. RF Guns for Generation of Polarized Electron Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clendenin, J.E.; Brachmann, A.; Dowell, D.H.

    2005-11-09

    Several accelerators, including the SLC, JLAB, Mainz, Bates/MIT, and Bonn have successfully operated for medium and high energy physics experiments using polarized electron beams generated by dc-biased guns employing GaAs photocathodes. Since these guns have all used a bias on the order of 100 kV, the longitudinal emittance of the extracted bunch is rather poor. Downstream rf bunching systems increase the transverse emittance. An rf gun with a GaAs photocathode would eliminate the need for separate rf bunchers, resulting in a simpler injection system. In addition, the thermal emittance of GaAs-type cathodes is significantly lower than for other photocathode materials.more » The environmental requirements for operating activated GaAs photocathodes cannot be met by rf guns as currently designed and operated. These requirements, including limits on vacuum and electron back bombardment, are discussed in some detail. Modifications to actual and proposed rf gun designs that would allow these requirements to be met are presented.« less

  18. Specifying the role of exposure to violence and violent behavior on initiation of gun carrying: a longitudinal test of three models of youth gun carrying.

    PubMed

    Spano, Richard; Pridemore, William Alex; Bolland, John

    2012-01-01

    Two waves of longitudinal data from 1,049 African American youth living in extreme poverty are used to examine the impact of exposure to violence (Time 1) and violent behavior (Time 1) on first time gun carrying (Time 2). Multivariate logistic regression results indicate that (a) violent behavior (Time 1) increased the likelihood of initiation of gun carrying (Time 2) by 76% after controlling for exposure to violence at Time 1, which is consistent with the stepping stone model of youth gun carrying, and (b) youth who were both exposed to violence at Time 1 and engaged in violent behavior at Time 1 were more than 2.5 times more likely to initiate gun carrying at Time 2 compared to youth who had neither of these characteristics, which supports the cumulative risk model of youth gun carrying. The authors discuss the implications of these findings in clarifying the role of violence in the community on youth gun carrying and the primary prevention of youth gun violence.

  19. Engineering design of the PLX- α coaxial gun

    NASA Astrophysics Data System (ADS)

    Cruz, E.; Brockington, S.; Case, A.; Luna, M.; Witherspoon, F. D.; Thio, Y. C. Francis; PLX-α Team

    2017-10-01

    We describe the engineering and technical improvements, as well as provide a detailed overview of the design choices, of the latest PLX- α coaxial gun designed for the 60-gun scaling study of spherically imploding plasma liners as a standoff driver for plasma-jet-driven magneto-inertial fusion. Each coaxial gun incorporates a fast, dense gas injection and triggering system, a compact low-weight pfn with integral sparkgap switching, and a contoured gap designed to suppress the blow-by instability. The evolution of the latest Alpha gun is presented with emphasis on its upgraded performance. Changes include a faster more robust gas valve, better-quality ceramic insulator material and enhancements to overall design layout. These changes result in a gun with increased repeatability, reduced potential failure modes, improved fault tolerance and better than expected efficiency. A custom 600- μF, 5-kV pfn and a set of six inline sparkgap switches operated in parallel are mounted directly to the back of the gun, and are designed to reduce inductance, cost, and complexity, maximize efficiency and system reliability, and ensure symmetric current flow. This work supported by the ARPA-E ALPHA Program under contract DE-AR0000566 and Strong Atomics, LLC.

  20. Investigations and Applications of Field- and Photo-emitted Electron Beams from a Radio Frequency Gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Panuganti, SriHarsha

    Production of quality electron bunches using e cient ways of generation is a crucial aspect of accelerator technology. Radio frequency electron guns are widely used to generate and rapidly accelerate electron beams to relativistic energies. In the current work, we primarily study the charge generation processes of photoemission and eld emission inside an RF gun installed at Fermilab's High Brightness Electron Source Laboratory (HBESL). Speci cally, we study and characterize second-order nonlinear photoemission from a Cesium Telluride (Cs 2Te) semiconductor photocathode, and eld emission from carbon based cathodes including diamond eld emission array (DFEA) and carbon nanotube (CNT) cathodes locatedmore » in the RF gun's cavity. Finally, we discuss the application experiments conducted at the facility to produce soft x-rays via inverse Compton scattering (ICS), and to generate uniformly lled ellipsoidal bunches and temporally shaped electron beams from the Cs 2Te photocathode.« less

  1. Spectrometer gun

    DOEpatents

    Waechter, David A.; Wolf, Michael A.; Umbarger, C. John

    1985-01-01

    A hand-holdable, battery-operated, microprocessor-based spectrometer gun includes a low-power matrix display and sufficient memory to permit both real-time observation and extended analysis of detected radiation pulses. Universality of the incorporated signal processing circuitry permits operation with various detectors having differing pulse detection and sensitivity parameters.

  2. Demonstration of Advanced Technologies for Multi-Load Washers in Hospitality and Healthcare -- Ozone Based Laundry Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyd, Brian K.; Parker, Graham B.; Petersen, Joseph M.

    The objective of this demonstration project was to evaluate market-ready retrofit technologies for reducing the energy and water use of multi-load washers in healthcare and hospitality facilities. Specifically, this project evaluated laundry wastewater recycling technology in the hospitality sector and ozone laundry technology in both the healthcare and hospitality sectors. This report documents the demonstration of ozone laundry system installations at the Charleston Place Hotel in Charleston, South Carolina, and the Rogerson House assisted living facility in Boston, Massachusetts.

  3. Mass Shootings, Mental Illness, and Gun Control.

    PubMed

    Philpott-Jones, Sean

    2018-03-01

    In the wake of the Stoneman Douglas School shooting, Republican and Democratic leaders-like the American electorate they represent-remain sharply divided in their responses to gun violence. They are united in their condemnation of these mass shootings, but they disagree about whether stricter or looser gun control laws are the answer. Those on the right side of the political aisle suggest that the issue is one of mental illness rather than gun control. Conversely, those who are more liberal or progressive in their political learnings are quick to condemn attempts to reframe the issue of mass shootings as a mental health problem. Both sides are wrong. Mass shootings are indeed partially a mental health problem, albeit one poorly addressed by our current laws and policies. But the solution to mass shootings also needs to consider strategies that may reduce gun violence in general. © 2018 The Hastings Center.

  4. Design and development of a 40 kV pierce electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhattacharjee, D.; Tiwari, R.; Jayaprakash, D., E-mail: dhruva.bhattacharjee@gmail.com

    A 40 kV electron gun is designed and developed using the Pierce configuration for the focusing electrode. Simulations were carried out using CST Particle Studio. The Gun is a thermionic type electron gun with indirect heating of the LaB6 cathode. The gun is capable of delivering a beam current of more than 500 mA at 40 kV with a beam size of less than 5 mm. The cathode assembly consists of cups and heat shields made out of Tantalum and Rhenium sheets. The cathode assembly and the electron gun was fabricated, assembled and tested on test bench for cathode conditioning,more » HV conditioning and beam characterization. This paper presents the gun design, particle simulations study, testing of the gun on test bench. (author)« less

  5. Handgun waiting periods reduce gun deaths.

    PubMed

    Luca, Michael; Malhotra, Deepak; Poliquin, Christopher

    2017-11-14

    Handgun waiting periods are laws that impose a delay between the initiation of a purchase and final acquisition of a firearm. We show that waiting periods, which create a "cooling off" period among buyers, significantly reduce the incidence of gun violence. We estimate the impact of waiting periods on gun deaths, exploiting all changes to state-level policies in the Unites States since 1970. We find that waiting periods reduce gun homicides by roughly 17%. We provide further support for the causal impact of waiting periods on homicides by exploiting a natural experiment resulting from a federal law in 1994 that imposed a temporary waiting period on a subset of states. Copyright © 2017 the Author(s). Published by PNAS.

  6. Unusual Case of Suicide With a Modified Trap Gun.

    PubMed

    Vadysinghe, Amal; Dassanayake, Prasanna; Wickramasinghe, Medhani

    2017-06-01

    Trap gun is an illegal, locally manufactured gun with a basic trip system used to hunt wild animals. The body of a 28-year-old man was found in the jungle in supine position with both legs apart. A trap gun was between the legs pointing toward the cranial side of the body. It had 2 free wires that were not connected together. There was no evidence of foul play.The body had a single-entry wound (2.5-cm diameter) in the anterior chest, with blackening, burning, and tattooing. Six metal particles and nylon clothing material were embedded into soft tissue. No exit wound was found. Toxicology analysis reported an alcohol level of 72 mg/dL. The cause of death was multiple shrapnel injury to the chest at close to intermediate range by a single discharge from a trap gun. Circumstance was concluded as suicide.Ballistic and firearm experts opined that an illegal, manually operated, battery-powered ignition device was used to ignite the gun powder. We report the first case of suicide by a modified trap gun in literature.

  7. Contoured-gap coaxial guns for imploding plasma liner experiments

    NASA Astrophysics Data System (ADS)

    Witherspoon, F. D.; Case, A.; Brockington, S.; Cassibry, J. T.; Hsu, S. C.

    2014-10-01

    Arrays of supersonic, high momentum flux plasma jets can be used as standoff compression drivers for generating spherically imploding plasma liners for driving magneto-inertial fusion, hence the name plasma-jet-driven MIF (PJMIF). HyperV developed linear plasma jets for the Plasma Liner Experiment (PLX) at LANL where two guns were successfully tested. Further development at HyperV resulted in achieving the PLX goal of 8000 μg at 50 km/s. Prior work on contoured-gap coaxial guns demonstrated an approach to control the blowby instability and achieved substantial performance improvements. For future plasma liner experiments we propose to use contoured-gap coaxial guns with small Minirailgun injectors. We will describe such a gun for a 60-gun plasma liner experiment. Discussion topics will include impurity control, plasma jet symmetry and topology (esp. related to uniformity and compactness), velocity capability, and techniques planned for achieving gun efficiency of >50% using tailored impedance matched pulse forming networks. Mach2 and UAH SPH code simulations will be included. Work supported by US DOE DE-FG02-05ER54810.

  8. National attitudes concerning gun carrying in the United States

    PubMed Central

    Hemenway, D; Azrael, D; Miller, M

    2001-01-01

    Objectives—To determine public attitudes in the United States concerning gun carrying. Setting—In the past 15 years, many state legislatures have passed laws making it easier for United States citizens to carry concealed firearms, not only on the street but into various locations, including churches and government buildings. Methods—National random digit dial telephone surveys conducted in 1996 and 1999 asked questions concerning the public's feelings of safety as more people in their community carry firearms, and whether, in the language of the question, respondents believe "regular" citizens should be allowed to carry guns into public or government buildings. Results—Americans feel less safe rather than more safe as more people in their community begin to carry guns. By margins of at least nine to one, Americans do not believe that "regular" citizens should be allowed to bring their guns into restaurants, college campuses, sports stadiums, bars, hospitals, or government buildings. Conclusions—The public believes that increased gun carrying by others reduces rather than increases their safety. Overwhelmingly, the public believes that in many venues gun carrying should be prohibited. PMID:11770652

  9. Spectrometer gun

    DOEpatents

    Waechter, D.A.; Wolf, M.A.; Umbarger, C.J.

    1981-11-03

    A hand-holdable, battery-operated, microprocessor-based spectrometer gun is described that includes a low-power matrix display and sufficient memory to permit both real-time observation and extended analysis of detected radiation pulses. Universality of the incorporated signal processing circuitry permits operation with various detectors having differing pulse detection and sensitivity parameters.

  10. Design and development of progressive tool for manufacturing washer

    NASA Astrophysics Data System (ADS)

    Annigeri, Ulhas K.; Raghavendra Ravi Kiran, K.; Deepthi, Y. P.

    2017-07-01

    In a progressive tool the raw material is worked at different station to finally fabricate the component. A progressive tool is a lucrative tool for mass production of components. A lot of automobile and other transport industries develop progressive tool for the production of components. The design of tool involves lot of planning and the same amount of skill of process planning is required in the fabrication of the tool. The design also involves use of thumb rules and standard elements as per experience gained in practice. Manufacturing the press tool is a laborious task as special jigs and fixtures have to be designed for the purpose. Assembly of all the press tool elements is another task where use of accurate measuring instruments for alignment of various tool elements is important. In the present study, design and fabrication of progressive press tool for production of washer has been developed and the press tool has been tried out on a mechanical type of press. The components produced are to dimensions.

  11. Youth, Guns, and the Juvenile Justice System. Research Report.

    ERIC Educational Resources Information Center

    Butts, Jeffrey; Coggeshall, Mark; Gouvis, Caterina; Mears, Daniel; Travis, Jeremy; Waul, Michelle; White, Ruth

    This report documents trends in youth gun violence and the response within the justice system, noting the growing variety of data resources available to investigate the effect of new gun laws on youth, communities, and public safety. The first section reviews recent trends, examining the major wave of gun violence in the United States during the…

  12. Water guns affect abundance and behavior of bigheaded carp and native fish differently

    USGS Publications Warehouse

    Rivera, Jose; Glover, David C.; Kocovsky, Patrick; Garvey, James E.; Gaikowski, Mark; Jensen, Nathan R.; Adams, Ryan F.

    2018-01-01

    Water guns have shown the potential to repel nuisance aquatic organisms. This study examines the effects of exposure to a 1966.4 cm3 seismic water gun array (two guns) on the abundance and behavior of Bighead Carp Hypophthalmichthys nobilis, Silver Carp H. molitrix (collectively referred to as bigheaded carp) and native fishes (e.g., Smallmouth Buffalo Ictiobus bubalus). Water guns were deployed in a channel that connects the Illinois River to backwater quarry pits that contained a large transient population of bigheaded carp. To evaluate the effect of water guns, mobile side-looking split-beam hydroacoustic surveys were conducted before, during and between replicated water gun firing periods. Water guns did not affect abundance of bigheaded carp, but abundance of native fish detected during the firing treatment was 43 and 34% lower than the control and water guns off treatments, respectively. The proximity of bigheaded carp to the water gun array was similar between the water guns on and water guns off treatments. In contrast, the closest detected native fish were detected farther from the water guns during the water guns on treatment (mean ± SE, 32.38 ± 3.32 m) than during the water guns off treatment (15.04 ± 1.59 m). The water gun array had a greater impact on native fish species than on bigheaded carp. Caution should be taken to the extrapolation of these results to other fish species and to fish exposed to water guns in different environments (e.g., reduced shoreline interaction) or exposure to a larger array of water guns, or for use of water guns for purposes other than a barrier.

  13. 46th Annual Gun and Missile Systems Conference and Exhibition

    DTIC Science & Technology

    2011-09-01

    Grade Sensors Through Use of Accelerated Aging Principles Mr. Scott Gift 11657 Modeling of the Autofrettage Processes of a Gun Barrel Mr. Sudhir...Emissions Measured on the Outer Portion of a Composite Barrel Ms. Rushie Ghimire GUN & MISSILE SYSTEMS ADDITIONAL AUTHORS GUN & MISSILE SYSTEMS...X 3BCT 2BCT X 1BCT TACP COLT • BLUFOR scout squad engaged by enemy infantry and are overwhelmed by heavy machine gun fire 100m to their northwest

  14. VIEW OF SOUTH GUN EMPLACEMENT. NOTE THE EXCAVATED EDGE OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF SOUTH GUN EMPLACEMENT. NOTE THE EXCAVATED EDGE OF THE GUN BLOCK IN THE FOREGROUND. VIEW FACING NORTH - U.S. Naval Base, Pearl Harbor, Ford Island 5-Inch Antiaircraft Battery, South Gun Emplacement, Ford Island, Pearl City, Honolulu County, HI

  15. The electric rail gun for space propulsion

    NASA Technical Reports Server (NTRS)

    Bauer, D. P.; Barber, J. P.; Vahlberg, C. J.

    1981-01-01

    An analytic feasibility investigation of an electric propulsion concept for space application is described. In this concept, quasistatic thrust due to inertial reaction to repetitively accelerated pellets by an electric rail gun is used to propel a spacecraft. The study encompasses the major subsystems required in an electric rail gun propulsion system. The mass, performance, and configuration of each subsystem are described. Based on an analytic model of the system mass and performance, the electric rail gun mission performance as a reusable orbital transfer vehicle (OTV) is analyzed and compared to a 30 cm ion thruster system (BIMOD) and a chemical propulsion system (IUS) for payloads with masses of 1150 kg and 2300 kg. For system power levels in the range from 25 kW(e) to 100 kW(e) an electric rail gun OTV is more attractive than a BIMOD system for low Earth orbit to geosynchronous orbit transfer durations in the range from 20 to 120 days.

  16. Direct launch using the electric rail gun

    NASA Technical Reports Server (NTRS)

    Barber, J. P.

    1983-01-01

    The concept explored involves using a large single stage electric rail gun to achieve orbital velocities. Exit aerodynamics, launch package design and size, interior ballistics, system and component sizing and design concepts are treated. Technology development status and development requirements are identified and described. The expense of placing payloads in Earth orbit using conventional chemical rockets is considerable. Chemical rockets are very inefficient in converting chemical energy into payload kinetic energy. A rocket motor is relatively expensive and is usually expended on each launch. In addition specialized and expensive forms of fuel are required. Gun launching payloads directly to orbit from the Earth's surface is a possible alternative. Guns are much more energy efficient than rockets. The high capital cost of the gun installation can be recovered by reusing it over and over again. Finally, relatively inexpensive fuel and large quantities of energy are readily available to a fixed installation on the Earth's surface.

  17. Impact of Firearm Availability and Gun Regulation on State Suicide Rates.

    PubMed

    Kposowa, Augustine; Hamilton, David; Wang, Katy

    2016-12-01

    Past studies on suicide have investigated the association of firearm ownership and suicide risk in the United States. The aim of the present study was to build on previous work by examining the impact of firearm storage practices and the strictness of firearm regulation on suicide rates at the state level. Data were compiled from primarily three sources. Suicide and firearm ownership information was obtained from the Centers for Disease Control and Prevention. Strictness of handgun regulation was derived from figures available at the Law Center to Prevent Violence, and controls were taken from the US Bureau of the Census. Mixed models were fitted to the data. Household firearm ownership was strongly associated with both suicide by all mechanisms, and firearm suicide. Storage practices had especially elevated consequences on suicide rates. Percent with loaded guns and gun readiness increased suicide rates, and strictness of gun regulation reduced suicide rates. Ready access to firearms can make a difference between life and death. Loaded and unlocked firearms within reach become risk factors for fatal outcomes from suicidal behavior. Future research might want to examine ways of obtaining more recent data on individual firearm ownership. This study proposes several policy recommendations for suicide prevention. © 2016 The American Association of Suicidology.

  18. Pediatricians' involvement in gun injury prevention.

    PubMed

    Olson, L M; Christoffel, K K; O'Connor, K G

    2007-04-01

    Injuries from small arms are of concern internationally. The health perspective is an emerging aspect of international work to reduce these injuries. This aspect has been evident in US firearm injury prevention work for over a decade, exhibited by strong statements from the American Academy of Pediatrics (AAP) to remove firearms from children's environments. To assess trends among US pediatricians related to firearm injury prevention counseling practices and attitudes toward gun legislation. National random sample, mailed surveys of AAP members: (1) 1994 (response rate = 68.9%, n = 982); (2) 2000 (response rate = 62.4%, n = 922). chi(2) Tests were used to assess bivariate relationships and logistic regression to assess multivariate relationships regarding counseling practices. Respondents in both years believed that violence prevention should be a priority for pediatricians (91.4% and 92.0%) and reported always or sometimes recommending handgun removal from the home (46.2% and 55.9%, respectively). In 2000, 74% of the respondents were comfortable discussing firearm safety; fewer thought they had sufficient training (32.7%) or time (27.5%) to discuss firearms. In 1994 and 2000, the likelihood of counseling on handgun removal was positively related to recent experience treating a gun injury, female sex and not owning a gun. In both years, >80% of pediatricians thought that gun control legislation or regulations would reduce injury and death. US pediatricians continue to adopt policies promoting gun injury prevention. The practices and attitudes of pediatricians may be important for public education strategies regarding firearm injury prevention in the US and internationally.

  19. Cognitive restructuring and exposure with a compulsive washer: a test of reciprocal inhibition.

    PubMed

    Giles, T R

    1982-09-01

    Reciprocal inhibition was tested with a compulsive washer using the affect elicited by rational self-statements as the response competitor to anxiety. Three conditions, CS alone, CS plus irrational self-statements, and CS plus rational self-statements, were randomly and continuously repeated over six trials. The CS was presented both imaginally and in vivo. It was hypothesized: (1) that subjective anxiety in all conditions would substantially diminish by the experiment's end; (2) that the rational self-statement condition would reduce (inhibit) subjective anxiety to a significantly greater degree than the other two conditions; and (3) that significant anxiety reduction would occur only during the rational restructuring trials. All three hypotheses were supported by the results.

  20. ION GUN

    DOEpatents

    Dandl, R.A.

    1961-10-24

    An ion gun is described for the production of an electrically neutral ionized plasma. The ion gun comprises an anode and a cathode mounted in concentric relationship with a narrow annulus between. The facing surfaces of the rear portions of the anode and cathode are recessed to form an annular manifold. Positioned within this manifold is an annular intermediate electrode aligned with the an nulus between the anode and cathode. Gas is fed to the manifold and an arc discharge is established between the anode and cathode. The gas is then withdrawn from the manifold through the annulus between the anode and cathode by a pressure differential. The gas is then ionized by the arc discharge across the annulus. The ionized gas is withdrawn from the annulus by the combined effects of the pressure differential and a collimating magnetic field. In a 3000 gauss magnetic field, an arc voltage of 1800 volts, and an arc current of 0.2 amp, a plasma of about 3 x 10/sup 11/ particles/cc is obtained. (AEC)

  1. Planning Support for Maintenance and Overhaul of Gun Weapon Systems

    DTIC Science & Technology

    1981-05-01

    13 (shielded twin) gun mounts are targeted to receive ORDALTs 9335 and 9409. Sixty-seven ship hulls are involved in the program, for a total of 147...gun mounts (excluding four training mounts ). Seventy-three Mod 0 and seventy-four Mod 13 gun mounts are included in the program, for an estimated total ...of gun mounts included in the GWSIP. Each mount will receive one amplifier ORDALT, for a. a total of 147, and two upgraded oscillating assemblies

  2. Light gas gun with reduced timing jitter

    DOEpatents

    Laabs, Gary W.; Funk, David J.; Asay, Blaine W.

    1998-01-01

    Gas gun with reduced timing jitter. A gas gun having a prepressurized projectile held in place with a glass rod in compression is described. The glass rod is destroyed with an explosive at a precise time which allows a restraining pin to be moved and free the projectile.

  3. Gun Control: The Debate and Public Policy.

    ERIC Educational Resources Information Center

    Watkins, Christine

    1997-01-01

    Provides an overview and background information on the debate over gun control, as well as several teaching ideas. Handouts include a list of related topics drawn from various disciplines (economics, U.S. history), seven arguments for and against gun control, and a set of policy evaluation guidelines. (MJP)

  4. Does gun accessibility lead to violence-related injury?

    PubMed

    Downey, La Vonne A; Zun, Leslie S; Burke, Trena; Jefferson, Tangula

    2013-02-01

    Because of high rates of violent gun-related injuries seen in emergency department (EDs), the ED has become involved in prevention violence intervention. The purpose of the study was to determine the relation between access to guns and the risk of violence-related injuries in youth and young adults. This study was a convenience sample in an inner-city level I trauma center. A 28-item validated questionnaire consisting of a short questionnaire about guns, the New York City Youth Violence Survey, and the SAGE Baseline Survey was given to 201 subjects. Half of the subjects were victims of violence and half were seen for nonviolence-related problems. Subjects with violence-related injuries did not have a higher rate of accessibility to guns. They did, however, show a difference in their attitudes toward guns. The subjects who came into the ED with violence-related injuries believed that having a weapon was a way to avoid a fight (F = 4.68, P = 0.032). They were more likely to have grabbed or shoved someone in the last 6 months (F = 5.18, P = 0.025), punched someone in the last 6 months (F = 11.9, P = 0.011), and have been seen in the ED within the last 6 months for a injury related to being punched, attacked, or shot (F = 117, P = 0.00), as compared to those with nonviolence-related injuries. There was no difference between the two subject groups in terms of their being victims of violence and the rate of gun accessibility. There was, however, a difference in their attitudes toward guns.

  5. Cure violence: a public health model to reduce gun violence.

    PubMed

    Butts, Jeffrey A; Roman, Caterina Gouvis; Bostwick, Lindsay; Porter, Jeremy R

    2015-03-18

    Scholars and practitioners alike in recent years have suggested that real and lasting progress in the fight against gun violence requires changing the social norms and attitudes that perpetuate violence and the use of guns. The Cure Violence model is a public health approach to gun violence reduction that seeks to change individual and community attitudes and norms about gun violence. It considers gun violence to be analogous to a communicable disease that passes from person to person when left untreated. Cure Violence operates independently of, while hopefully not undermining, law enforcement. In this article, we describe the theoretical basis for the program, review existing program evaluations, identify several challenges facing evaluators, and offer directions for future research.

  6. 27 CFR 479.105 - Transfer and possession of machine guns.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... machine guns. 479.105 Section 479.105 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES, AND CERTAIN OTHER FIREARMS Registration and Identification of Firearms Machine Guns § 479.105 Transfer...

  7. 27 CFR 479.105 - Transfer and possession of machine guns.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... machine guns. 479.105 Section 479.105 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES, AND CERTAIN OTHER FIREARMS Registration and Identification of Firearms Machine Guns § 479.105 Transfer...

  8. 27 CFR 479.105 - Transfer and possession of machine guns.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... machine guns. 479.105 Section 479.105 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES, AND CERTAIN OTHER FIREARMS Registration and Identification of Firearms Machine Guns § 479.105 Transfer...

  9. 27 CFR 479.105 - Transfer and possession of machine guns.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... machine guns. 479.105 Section 479.105 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES, AND CERTAIN OTHER FIREARMS Registration and Identification of Firearms Machine Guns § 479.105 Transfer...

  10. 27 CFR 479.105 - Transfer and possession of machine guns.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... machine guns. 479.105 Section 479.105 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO, FIREARMS, AND EXPLOSIVES, DEPARTMENT OF JUSTICE FIREARMS AND AMMUNITION MACHINE GUNS, DESTRUCTIVE DEVICES, AND CERTAIN OTHER FIREARMS Registration and Identification of Firearms Machine Guns § 479.105 Transfer...

  11. Evaluation of high frequency ghost cavitation emissions for two different seismic air-gun arrays using numerical modelling

    NASA Astrophysics Data System (ADS)

    Khodabandeloo, Babak; Landrø, Martin

    2017-04-01

    Sound is deployed by marine mammals for variety of vital purposes such as finding food, communication, echolocation, etc. On the other hand human activities generate underwater noise. One major type of acoustic source is marine seismic acquisition which is carried out to image layers beneath the seabed exploiting reflected acoustic and elastic waves. Air-gun arrays are the most common and efficient marine seismic sources. Field measurements using broad band hydrophones have revealed that acoustic energies emitted by air-gun arrays contains frequencies from a few Hz up to tens of kHz. Frequencies below 200 Hz benefit seismic imaging and the rest is normally considered as wasted energy. On the other hand, the high frequency range (above 200 Hz) overlaps with hearing curves of many marine mammals and especially toothed whales and may have an impact on their behavior. A phenomenon called ghost cavitation is recently recognized to be responsible for a major part of these high frequencies (> 5 kHz). Acoustic pressure waves of individual air guns reflected from sea surface can cause the hydrostatic pressure to drop towards zero close to the source array. In these regions there is a high probability for water vapor cavity growth and subsequent collapse. We have simulated ghost cavitation cloud using numerical modelling and the results are validated by comparing with field measurements. The model is used to compare the amount of high frequency noise due to ghost cavitation for two different air gun arrays. Both of the arrays have three subarrays but the array distance for the one with 2730 in3 air volume is 6 meters and for the slightly bigger array (3250 in3 in air volume) the subarrays are separated by 8 meters. Simulation results indicate that the second array, despite larger subarray distance, generates stronger ghost cavitation signal.

  12. Controlled-Temperature Hot-Air Gun

    NASA Technical Reports Server (NTRS)

    Munoz, M. C.

    1986-01-01

    Materials that find applications in wind tunnels first tested in laboratory. Hot-Air Gun differs from commercial units in that flow rate and temperature monitored and controlled. With typical compressed-airsupply pressure of 25 to 38 psi (170 to 260 kPa), flow rate and maximum temperature are 34 stdft3/min (0.96 stdm3/min) and 1,090 degrees F (590 degrees C), respectively. Resembling elaborate but carefully regulated hot-air gun, setup used to apply blasts of air temperatures above 1,500 degrees F (815 degrees C) to test specimens.

  13. Individual-level risk factors for gun victimization in a sample of probationers.

    PubMed

    Wells, William; Chermak, Steven

    2011-07-01

    Interventions aimed at preventing the important problem of gun injuries could be improved with an understanding of whether there are unique factors that place individuals at an increased risk of gun victimization. Much remains to be known about the victims of gun violence. The purpose of this article is to assess whether there are individual-level variables uniquely related to the likelihood of experiencing a gun victimization in a sample of probationers, individuals already at a heightened risk for criminal victimization. Self-report data were collected from 235 felony probationers about, for instance, gun and nongun victimization, gang involvement, and drug sales. Results show different variables are related to nongun victimization and gun victimization. In the current sample, involvement in gun crimes are linked to an increased risk of gun victimization. Violent offending and residential stability are associated with an increased chance of crime victimization.

  14. Differences Between New and Long-Standing US Gun Owners: Results From a National Survey.

    PubMed

    Wertz, Joseph; Azrael, Deborah; Hemenway, David; Sorenson, Susan; Miller, Matthew

    2018-07-01

    To quantify the proportion of current US gun owners who are new to owning firearms and compare new versus long-standing gun owners with respect to their firearms and firearm-related behaviors. We performed a cross-sectional analysis of a nationally representative probability-based online survey conducted in 2015 in the United States. We defined new gun owners as current firearm owners who acquired all of their firearms within the past 5 years, but who lived in a home without a gun at some time over the past 5 years. We defined long-standing firearm owners as all other current gun owners. New gun owners represented 10% of all current US adult gun owners. In addition to being younger than long-standing gun owners, new gun owners were more likely to be liberal, own fewer guns, own handguns, own guns only for protection, and store guns in a safe manner. Gun ownership is dynamic, with approximately 1 million Americans becoming new gun owners each year. Public Health Implications. Clinical guidelines should be updated to explicitly endorse re-evaluating household firearm status at regular intervals.

  15. Light gas gun with reduced timing jitter

    DOEpatents

    Laabs, G.W.; Funk, D.J.; Asay, B.W.

    1998-06-09

    Gas gun with reduced timing jitter is disclosed. A gas gun having a prepressurized projectile held in place with a glass rod in compression is described. The glass rod is destroyed with an explosive at a precise time which allows a restraining pin to be moved and free the projectile. 4 figs.

  16. Gun policy and serious mental illness: priorities for future research and policy.

    PubMed

    McGinty, Emma Elizabeth; Webster, Daniel W; Barry, Colleen L

    2014-01-01

    In response to recent mass shootings, policy makers have proposed multiple policies to prevent persons with serious mental illness from having guns. The political debate about these proposals is often uninformed by research. To address this gap, this review article summarizes the research related to gun restriction policies that focus on serious mental illness. Gun restriction policies were identified by researching the THOMAS legislative database, state legislative databases, prior review articles, and the news media. PubMed, PsycINFO, and Web of Science databases were searched for publications between 1970 and 2013 that addressed the relationship between serious mental illness and violence, the effectiveness of gun policies focused on serious mental illness, the potential for such policies to exacerbate negative public attitudes, and the potential for gun restriction policies to deter mental health treatment seeking. Limited research suggests that federal law restricting gun possession by persons with serious mental illness may prevent gun violence from this population. Promotion of policies to prevent persons with serious mental illness from having guns does not seem to exacerbate negative public attitudes toward this group. Little is known about how restricting gun possession among persons with serious mental illness affects suicide risk or mental health treatment seeking. Future studies should examine how gun restriction policies for serious mental illness affect suicide, how such policies are implemented by states, how persons with serious mental illness perceive policies that restrict their possession of guns, and how gun restriction policies influence mental health treatment seeking among persons with serious mental illness.

  17. The US gun stock: results from the 2004 national firearms survey.

    PubMed

    Hepburn, L; Miller, M; Azrael, D; Hemenway, D

    2007-02-01

    To examine the size and composition of the privately held firearm stock in the US; and to describe demographic patterns of firearm ownership and motivations for ownership. A nationally representative household telephone survey of 2770 adults aged>or=18 years living in the US, conducted in the spring of 2004. Responses to questions regarding firearm ownership, the number and types of guns owned, and motivations for ownership. 38% of households and 26% of individuals reported owning at least one firearm. This corresponds to 42 million US households with firearms, and 57 million adult gun owners. 64% of gun owners or 16% of American adults reported owning at least one handgun. Long guns represent 60% of the privately held gun stock. Almost half (48%) of all individual gun owners reported owning>or=4 firearms. Men more often reported firearm ownership, with 45% stating that they personally owned at least one firearm, compared with 11% for women. The US population continues to contain at least one firearm for every adult, and ownership is becoming increasingly concentrated. Long guns are the most prevalent type of gun in the US but handgun ownership is widespread. Ownership demographic patterns support findings of previous studies.

  18. International correlations between gun ownership and rates of homicide and suicide.

    PubMed Central

    Killias, M

    1993-01-01

    OBJECTIVE: To examine international correlations between reported rates of household gun ownership and rates of homicide and suicide with a gun. DESIGN: Survey. POPULATION: People who responded to a telephone survey conducted by the 1989 International Crime Survey in 11 European countries, Australia, Canada and the United States. RESULTS: Positive correlations were obtained between the rates of household gun ownership and the national rates of homicide and suicide as well as the proportions of homicides and suicides committed with a gun. There was no negative correlation between the rates of ownership and the rates of homicide and suicide committed by other means; this indicated that the other means were not used to "compensate" for the absence of guns in countries with a lower rate of gun ownership. CONCLUSION: Larger studies are needed to examine more closely possible confounding factors such as the national tendency toward violent solutions, and more information on the type and availability of guns will be helpful in future studies. Nevertheless, the correlations detected in this study suggest that the presence of a gun in the home increases the likelihood of homicide or suicide. PMID:8485675

  19. Performance of a clinical gridded electron gun in magnetic fields: Implications for MRI-linac therapy.

    PubMed

    Whelan, Brendan; Holloway, Lois; Constantin, Dragos; Oborn, Brad; Bazalova-Carter, Magdalena; Fahrig, Rebecca; Keall, Paul

    2016-11-01

    MRI-linac therapy is a rapidly growing field, and requires that conventional linear accelerators are operated with the fringe field of MRI magnets. One of the most sensitive accelerator components is the electron gun, which serves as the source of the beam. The purpose of this work was to develop a validated finite element model (FEM) model of a clinical triode (or gridded) electron gun, based on accurate geometric and electrical measurements, and to characterize the performance of this gun in magnetic fields. The geometry of a Varian electron gun was measured using 3D laser scanning and digital calipers. The electric potentials and emission current of these guns were measured directly from six dose matched true beam linacs for the 6X, 10X, and 15X modes of operation. Based on these measurements, a finite element model (FEM) of the gun was developed using the commercial software opera/scala. The performance of the FEM model in magnetic fields was characterized using parallel fields ranging from 0 to 200 G in the in-line direction, and 0-35 G in the perpendicular direction. The FEM model matched the average measured emission current to within 5% across all three modes of operation. Different high voltage settings are used for the different modes; the 6X, 10X, and 15X modes have an average high voltage setting of 15, 10, and 11 kV. Due to these differences, different operating modes show different sensitivities in magnetic fields. For in line fields, the first current loss occurs at 40, 20, and 30 G for each mode. This is a much greater sensitivity than has previously been observed. For perpendicular fields, first beam loss occurred at 8, 5, and 5 G and total beam loss at 27, 22, and 20 G. A validated FEM model of a clinical triode electron gun has been developed based on accurate geometric and electrical measurements. Three different operating modes were simulated, with a maximum mean error of 5%. This gun shows greater sensitivity to in-line magnetic fields than

  20. Performance of a clinical gridded electron gun in magnetic fields: Implications for MRI-linac therapy

    PubMed Central

    Whelan, Brendan; Holloway, Lois; Constantin, Dragos; Oborn, Brad; Bazalova-Carter, Magdalena; Fahrig, Rebecca; Keall, Paul

    2016-01-01

    Purpose: MRI-linac therapy is a rapidly growing field, and requires that conventional linear accelerators are operated with the fringe field of MRI magnets. One of the most sensitive accelerator components is the electron gun, which serves as the source of the beam. The purpose of this work was to develop a validated finite element model (FEM) model of a clinical triode (or gridded) electron gun, based on accurate geometric and electrical measurements, and to characterize the performance of this gun in magnetic fields. Methods: The geometry of a Varian electron gun was measured using 3D laser scanning and digital calipers. The electric potentials and emission current of these guns were measured directly from six dose matched true beam linacs for the 6X, 10X, and 15X modes of operation. Based on these measurements, a finite element model (FEM) of the gun was developed using the commercial software opera/scala. The performance of the FEM model in magnetic fields was characterized using parallel fields ranging from 0 to 200 G in the in-line direction, and 0–35 G in the perpendicular direction. Results: The FEM model matched the average measured emission current to within 5% across all three modes of operation. Different high voltage settings are used for the different modes; the 6X, 10X, and 15X modes have an average high voltage setting of 15, 10, and 11 kV. Due to these differences, different operating modes show different sensitivities in magnetic fields. For in line fields, the first current loss occurs at 40, 20, and 30 G for each mode. This is a much greater sensitivity than has previously been observed. For perpendicular fields, first beam loss occurred at 8, 5, and 5 G and total beam loss at 27, 22, and 20 G. Conclusions: A validated FEM model of a clinical triode electron gun has been developed based on accurate geometric and electrical measurements. Three different operating modes were simulated, with a maximum mean error of 5%. This gun shows greater

  1. The Baltimore Youth Ammunition Initiative: a model application of local public health authority in preventing gun violence.

    PubMed

    Lewin, Nancy L; Vernick, Jon S; Beilenson, Peter L; Mair, Julie S; Lindamood, Melisa M; Teret, Stephen P; Webster, Daniel W

    2005-05-01

    In 2002, the Baltimore City Health Department, in collaboration with the Baltimore Police Department and the Johns Hopkins Center for Gun Policy and Research, launched the Youth Ammunition Initiative. The initiative addressed Baltimore's problem of youth gun violence by targeting illegal firearm ammunition sales to the city's young people. The initiative included undercover "sting" investigations of local businesses and issuance of health department violation and abatement notices. Intermediate results included the passage of 2 Baltimore city council ordinances regulating ammunition sales and reducing the number of outlets eligible to sell ammunition. Although it is too early to assess effects on violent crime, the intervention could theoretically reduce youth violence by interrupting one source of ammunition to youths. More important, the initiative can serve as a policy model for health commissioners seeking to become more active in gun violence prevention efforts.

  2. Pediatricians’ involvement in gun injury prevention

    PubMed Central

    Olson, L M; Christoffel, K K; O’Connor, K G

    2007-01-01

    Background: Injuries from small arms are of concern internationally. The health perspective is an emerging aspect of international work to reduce these injuries. This aspect has been evident in US firearm injury prevention work for over a decade, exhibited by strong statements from the American Academy of Pediatrics (AAP) to remove firearms from children’s environments. Objectives: To assess trends among US pediatricians related to firearm injury prevention counseling practices and attitudes toward gun legislation. Design: National random sample, mailed surveys of AAP members: (1) 1994 (response rate  = 68.9%, n = 982); (2) 2000 (response rate  = 62.4%, n = 922). χ2 Tests were used to assess bivariate relationships and logistic regression to assess multivariate relationships regarding counseling practices. Results: Respondents in both years believed that violence prevention should be a priority for pediatricians (91.4% and 92.0%) and reported always or sometimes recommending handgun removal from the home (46.2% and 55.9%, respectively). In 2000, 74% of the respondents were comfortable discussing firearm safety; fewer thought they had sufficient training (32.7%) or time (27.5%) to discuss firearms. In 1994 and 2000, the likelihood of counseling on handgun removal was positively related to recent experience treating a gun injury, female sex and not owning a gun. In both years, >80% of pediatricians thought that gun control legislation or regulations would reduce injury and death. Conclusions: US pediatricians continue to adopt policies promoting gun injury prevention. The practices and attitudes of pediatricians may be important for public education strategies regarding firearm injury prevention in the US and internationally. PMID:17446249

  3. Guns, Mental Illness, and the Law: Introduction to This Issue.

    PubMed

    Swanson, Jeffrey W; Felthous, Alan R

    2015-06-01

    Firearm violence is a top-tier public health problem in the U.S., killing 33,563 and injuring an additional 81,396 people in 2012 (Centers for Disease Control and Prevention, CDC, ). Given constitutional protection and the cultural entrenchment of private gun ownership in the U.S., it is likely that guns will remain widely accessible--and largely unrestricted--for the foreseeable future. Therefore, most policies and laws intended to reduce firearm violence focus selectively on preventing "dangerous people" from having access to guns. That is a formidable challenge. How do we think productively about guns and mental illness in this context, and about the role of law in lessening the toll of gun violence? Copyright © 2015 John Wiley & Sons, Ltd.

  4. Multipacting simulation and test results of BNL 704 MHz SRF gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu W.; Belomestnykh, S.; Ben-Zvi, I.

    The BNL 704MHz SRF gun has a grooved choke joint to support the photo-cathode. Due to the distortion of grooves at the choke joint during the BCP for the choke joint, several multipacting barriers showed up when it was tested with Nb cathode stalk at JLab. We built a setup to use the spare large grain SRF cavity to test and condition the multipacting at BNL with various power sources up to 50kW. The test is carried out in three stages: testing the cavity performance without cathode, testing the cavity with the Nb cathode stalk that was used at Jlab,more » and testing the cavity with a copper cathode stalk that is based on the design for the SRF gun. This paper summarizes the results of multipacting simulation, and presents the large grain cavity test setup and the test results.« less

  5. [Contextual study of Airsoft gun related ocular injuries].

    PubMed

    Rambaud, C; Tabary, A; Contraires, G; El Hassan, F; Labalette, P

    2013-03-01

    Airsoft guns have become more common in France since the Decree of March 24, 1999, allowing people over 18 years of age to use weapons with an energy level below 2J. The present study aimed to assess the relationship between the context of Airsoft gun pellet related ocular injuries and their clinical consequences, in order to determine an effective prevention strategy. A retrospective analysis of ocular injuries due to Airsoft gun pellets was conducted in two hospitals in northern France between September 2009 and August 2010. Six patients with a mean age of 12.6 ± 3.2 years were included. The most frequent injuries were corneal abrasion, hyphema and iris trauma. Functional sequelae were observed in 50% of cases and surgical intervention was necessary in one third of cases. A direct shot had occurred in all cases. In 83% of cases, the accident took place while playing in or around the house. In one out of every two cases, the gun had been won at a booth in a fair or had been purchased in a big-box store and in no cases did the patients own safety glasses. The strong appeal of Airsoft guns to minors leads us to propose several practical measures to help protect them, with the main one being to forbid selling these guns outside of specialized stores. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  6. Characterization of the C-2W Plasma Guns

    NASA Astrophysics Data System (ADS)

    Dubois, Ami; Sokolov, Vladimir; Korepanov, Sergey; Osin, Dima; Player, Gabriel; TAE Team

    2017-10-01

    Previous use of coaxial arc discharge plasma guns on the C-2U device exhibited great success in plasma stabilization and improved confinement. On the C-2W experiment, arc discharge plasma guns will again be used to facilitate the electrical connection between the plasma core and the divertor electrodes in order to maintain the electrode edge biasing and induce E x B shear to control plasma rotation. Each plasma gun contains an internal solenoid used to shape the plasma stream. Characterization of electron density (ne) , electron temperature (Te) , floating potential (Vf) , and total plasma flux in an arc discharge lasting 6 ms without the internal solenoid are presented. A Langmuir probe located 27 cm axially outside of the plasma gun anode measures a bell-like radial ne profile with peak ne 1018 m-3 and Te 2 - 10 eV. Observed spectral lines of impurity ions provide an estimate of Te, and Balmer series line ratios of the main ion component are used to evaluate ne at both the probe location and near the plasma gun anode. A calorimeter measures the plasma flux to be constant and equivalent to 1 kA.

  7. Gun-Control Legislation and the Impact on Suicide.

    PubMed

    Leenaars, Antoon A

    2007-01-01

    Gun control is the prototypical example of controlling the environment for the means of suicide, an effective public health approach to suicide prevention. Canada's Criminal Law Amendment Act of 1977 (Bill C-51) provides an excellent opportunity to illustrate the effects of legislative gun-control laws and the impact on suicide. The research in Canada supports the significant effect of C-51 in reducing suicides and firearm suicides, even if one controls for socioeconomic factors, although not equally for all ages. The young, a high-risk group, show the most significant decrease, without significant substitution of other methods (displacement). Studies on gun-control laws from New Zealand, the United States, and Australia support the Canadian findings. It is concluded that, although not equally applicable in all countries, gun control may well have significant applications in reducing suicide worldwide.

  8. New light-gas guns for studying high-velocity impact at space velocities

    NASA Astrophysics Data System (ADS)

    Khristenko, Yuri F.

    2017-10-01

    The paper describes new light-gas guns for the high-velocity throwing of different projectiles: an upgraded two-stage light-gas powder gun and single-, two- and three-stage compressed light-gas guns. The paper also provides the schemes, pictures and characteristics of light-gas guns.

  9. Guns and Fear: A One-Way Street?

    ERIC Educational Resources Information Center

    Hauser, Will; Kleck, Gary

    2013-01-01

    Surveys show that more than one half of gun owners report owning their firearm for self-protection. Although research has examined the effect of fear of crime on gun ownership, the issue of reciprocity and temporal order has been largely ignored. Furthermore, the effect of firearm acquisition and relinquishment on fear has not been evaluated…

  10. Gun Violence and Children: Factors Related To Exposure and Trauma.

    ERIC Educational Resources Information Center

    Slovak, Karen

    2002-01-01

    Study investigated relationship between access to firearms and parental monitoring on rural youths' exposure to gun violence, and examined the effect of gun violence exposure on mental health. Results indicated a substantial number were exposed to gun violence. Exposure was related to firearm access and parental monitoring. Implications for social…

  11. Modifications Of A Commercial Spray Gun

    NASA Technical Reports Server (NTRS)

    Allen, Peter B.

    1993-01-01

    Commercial spray gun modified to increase spray rate and make sprayed coats more nearly uniform. Consists of gun head and pneumatic actuator. Actuator opens valves for two chemical components, called "A" and "B," that react to produce foam. Components flow through orifices, into mixing chamber in head. Mixture then flows through control orifice to spray tip. New spray tip tapered to reduce area available for accumulation of foam and makes tip easier to clean.

  12. From gunstore to smoking gun: tracking guns that kill children in North Carolina.

    PubMed

    Campbell, Brendan T; Radisch, Deborah L; Phillips, J Duncan; von Allmen, Daniel

    2004-12-01

    This study reviews the epidemiology of pediatric firearm deaths in North Carolina and estimates the time from the retail sale of guns to their involvement in pediatric firearm deaths. The authors reviewed autopsy reports for all children 0 to 14 years of age that died of firearm-related injuries in North Carolina from January 1999 through December 2002. Data obtained included demographic information, firearm type, and manner of death. Data from the Bureau of Alcohol, Tobacco and Firearms, which traced guns involved in crimes and determined the time elapsed from purchase to their involvement in a crime (ie, time-to-crime were also reviewed). During the study period, 40 children died of firearm injuries. Mean age was 7.6 years. Handguns were responsible for the majority of deaths (59%) followed by shotguns (27%), rifles (10%), and undetermined cause (10%). Most deaths were homicides (67%) followed by unintentional death (18%), suicide (13%), and undetermined cause (2%). Most crime guns (76%) were purchased legally, and many (40%) had a time-to-crime of less than 3 years. Legally purchased firearms pose a significant threat to children in North Carolina. A more restrictive approach to the sale of handguns is a logical approach to reducing pediatric firearm-related deaths in the United States.

  13. Coaxial-gun design and testing for the PLX- α Project

    NASA Astrophysics Data System (ADS)

    Witherspoon, F. Douglas; Brockington, Samuel; Case, Andrew; Cruz, Edward; Luna, Marco; Langendorf, Samuel

    2016-10-01

    We describe the Alpha coaxial gun designed for a 60-gun scaling study of spherically imploding plasma liners as a standoff driver for plasma-jet-driven magneto-inertial fusion (PJMIF). The guns operate over a range of parameters: 0.5-5.0 mg of Ar, Ne, N2, Kr, and Xe; 20-60 km/s; 2 × 1016 cm-3 muzzle density; and up to 7.5 kJ stored energy per gun. Each coaxial gun incorporates a fast dense gas injection and triggering system, a compact low-weight pfn with integral sparkgap switching, and a contoured gap designed to suppress the blow-by instability. The latest design iteration incorporates a faster more robust gas valve, an improved electrode contour, a custom 600- μF, 5-kV pfn, and six inline sparkgap switches operated in parallel. The switch and pfn are mounted directly to the back of the gun and are designed to reduce inductance, cost, and complexity, maximize efficiency and system reliability, and ensure symmetric current flow. We provide a brief overview of the design choices, the projected performance over the parameter ranges mentioned above, and experimental results from testing of the PLX- α coaxial gun. This work supported by the ARPA-E ALPHA Program.

  14. 27 CFR 478.36 - Transfer or possession of machine guns.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... machine guns. 478.36 Section 478.36 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO... Administrative and Miscellaneous Provisions § 478.36 Transfer or possession of machine guns. No person shall transfer or possess a machine gun except: (a) A transfer to or by, or possession by or under the authority...

  15. 27 CFR 478.36 - Transfer or possession of machine guns.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... machine guns. 478.36 Section 478.36 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO... Administrative and Miscellaneous Provisions § 478.36 Transfer or possession of machine guns. No person shall transfer or possess a machine gun except: (a) A transfer to or by, or possession by or under the authority...

  16. 27 CFR 478.36 - Transfer or possession of machine guns.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... machine guns. 478.36 Section 478.36 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO... Administrative and Miscellaneous Provisions § 478.36 Transfer or possession of machine guns. No person shall transfer or possess a machine gun except: (a) A transfer to or by, or possession by or under the authority...

  17. 27 CFR 478.36 - Transfer or possession of machine guns.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... machine guns. 478.36 Section 478.36 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO... Administrative and Miscellaneous Provisions § 478.36 Transfer or possession of machine guns. No person shall transfer or possess a machine gun except: (a) A transfer to or by, or possession by or under the authority...

  18. 27 CFR 478.36 - Transfer or possession of machine guns.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... machine guns. 478.36 Section 478.36 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO... Administrative and Miscellaneous Provisions § 478.36 Transfer or possession of machine guns. No person shall transfer or possess a machine gun except: (a) A transfer to or by, or possession by or under the authority...

  19. 46 CFR 160.031-4 - Equipment for shoulder gun type line-throwing appliance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 6 2014-10-01 2014-10-01 false Equipment for shoulder gun type line-throwing appliance... Appliance, Shoulder Gun Type (and Equipment) § 160.031-4 Equipment for shoulder gun type line-throwing... the gun. The line canister shall be secured by clamps or brackets below the barrel of the gun. (c) One...

  20. 46 CFR 160.031-4 - Equipment for shoulder gun type line-throwing appliance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Equipment for shoulder gun type line-throwing appliance... Appliance, Shoulder Gun Type (and Equipment) § 160.031-4 Equipment for shoulder gun type line-throwing... the gun. The line canister shall be secured by clamps or brackets below the barrel of the gun. (c) One...

  1. 46 CFR 160.031-4 - Equipment for shoulder gun type line-throwing appliance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 6 2013-10-01 2013-10-01 false Equipment for shoulder gun type line-throwing appliance... Appliance, Shoulder Gun Type (and Equipment) § 160.031-4 Equipment for shoulder gun type line-throwing... the gun. The line canister shall be secured by clamps or brackets below the barrel of the gun. (c) One...

  2. 46 CFR 160.031-4 - Equipment for shoulder gun type line-throwing appliance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 6 2012-10-01 2012-10-01 false Equipment for shoulder gun type line-throwing appliance... Appliance, Shoulder Gun Type (and Equipment) § 160.031-4 Equipment for shoulder gun type line-throwing... the gun. The line canister shall be secured by clamps or brackets below the barrel of the gun. (c) One...

  3. 46 CFR 160.031-4 - Equipment for shoulder gun type line-throwing appliance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Equipment for shoulder gun type line-throwing appliance... Appliance, Shoulder Gun Type (and Equipment) § 160.031-4 Equipment for shoulder gun type line-throwing... the gun. The line canister shall be secured by clamps or brackets below the barrel of the gun. (c) One...

  4. Automated Chromium Plating Line for Gun Barrels

    DTIC Science & Technology

    1979-09-01

    consistent pretreatments and bath dwell times. Some of the advantages of automated processing include increased productivity (average of 20^) due to...when automated processing procedures’ are used. The current method of applying chromium electrodeposits to gun tubes is a manual, batch operation...currently practiced with rotary swaged gun tubes would substantially reduce the difficulties in automated processing . RECOMMENDATIONS

  5. Should Gun Safety Be Taught in Schools? Perspectives of Teachers

    ERIC Educational Resources Information Center

    Obeng, Cecilia

    2010-01-01

    Background: Gun-related injuries and deaths among children occur at disproportionately high rates in the United States. Children who live in homes with guns are the most likely victims. This study describes teachers' views on whether gun safety should be taught to children in the preschool and elementary years. Methods: A total of 150 survey…

  6. The US gun stock: results from the 2004 national firearms survey

    PubMed Central

    Hepburn, L; Miller, M; Azrael, D; Hemenway, D

    2007-01-01

    Objectives To examine the size and composition of the privately held firearm stock in the US; and to describe demographic patterns of firearm ownership and motivations for ownership. Design, setting and participants A nationally representative household telephone survey of 2770 adults aged ⩾18 years living in the US, conducted in the spring of 2004. Main outcome measure Responses to questions regarding firearm ownership, the number and types of guns owned, and motivations for ownership. Results 38% of households and 26% of individuals reported owning at least one firearm. This corresponds to 42 million US households with firearms, and 57 million adult gun owners. 64% of gun owners or 16% of American adults reported owning at least one handgun. Long guns represent 60% of the privately held gun stock. Almost half (48%) of all individual gun owners reported owning ⩾4 firearms. Men more often reported firearm ownership, with 45% stating that they personally owned at least one firearm, compared with 11% for women. Conclusions The US population continues to contain at least one firearm for every adult, and ownership is becoming increasingly concentrated. Long guns are the most prevalent type of gun in the US but handgun ownership is widespread. Ownership demographic patterns support findings of previous studies. PMID:17296683

  7. Gun Testing Ballistics Issues for Insensitive Munitions Fragment Impact Testing

    NASA Astrophysics Data System (ADS)

    Baker, Ernest; Schultz, Emmanuel; NATO Munitions Safety Information Analysis Centre Team

    2017-06-01

    The STANAG 4496 Ed. 1 Fragment Impact, Munitions Test Procedure is normally conducted by gun launching a projectile for attack against a munition. The purpose of this test is to assess the reaction of a munition impacted by a fragment. The test specifies a standardized projectile (fragment) with a standard test velocity of 2530+/-90 m/s, or an alternate test velocity of 1830+/-60 m/s. The standard test velocity can be challenging to achieve and has several loosely defined and undefined characteristics that can affect the test item response. This publication documents the results of an international review of the STANAG 4496 related to the fragment impact test. To perform the review, MSIAC created a questionnaire in conjunction with the custodian of this STANAG and sent it to test centers. Fragment velocity variation, projectile tilt upon impact and aim point variation were identified as observed gun testing issues. Achieving 2530 m/s consistently and cost effectively can be challenging. The aim point of impact of the fragment is chosen with the objective of obtaining the most violent reaction. No tolerance for aim point is specified, although aim point variation can be a source for IM response variation. Fragment tilt on impact is also unspecified. The standard fragment fabricated from a variety of different steels which have a significant margin for mechanical properties. These, as well as other gun testing issues, have significant implications to resulting IM response.

  8. Performance of a first generation X-band photoelectron rf gun

    DOE PAGES

    Limborg-Deprey, C.; Adolphsen, C.; McCormick, D.; ...

    2016-05-04

    Building more compact accelerators to deliver high brightness electron beams for the generation of high flux, highly coherent radiation is a priority for the photon science community. A relatively straightforward reduction in footprint can be achieved by using high-gradient X-band (11.4 GHz) rf technology. To this end, an X-band injector consisting of a 5.5 cell rf gun and a 1-m long linac has been commissioned at SLAC. It delivers an 85 MeV electron beam with peak brightness somewhat better than that achieved in S-band photoinjectors, such as the one developed for the Linac Coherent Light Source (LCLS). The X-band rfmore » gun operates with up to a 200 MV/m peak field on the cathode, and has been used to produce bunches of a few pC to 1.2 nC in charge. Notably, bunch lengths as short as 120 fs rms have been measured for charges of 5 pC (~3×10 7 electrons), and normalized transverse emittances as small as 0.22 mm-mrad have been measured for this same charge level. Bunch lengths as short as 400 (250) fs rms have been achieved for electron bunches of 100 (20) pC with transverse normalized emittances of 0.7 (0.35) mm-mrad. As a result, we report on the performance and the lessons learned from the operation and optimization of this first generation X-band gun.« less

  9. Performance of a first generation X-band photoelectron rf gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Limborg-Deprey, C.; Adolphsen, C.; McCormick, D.

    Building more compact accelerators to deliver high brightness electron beams for the generation of high flux, highly coherent radiation is a priority for the photon science community. A relatively straightforward reduction in footprint can be achieved by using high-gradient X-band (11.4 GHz) rf technology. To this end, an X-band injector consisting of a 5.5 cell rf gun and a 1-m long linac has been commissioned at SLAC. It delivers an 85 MeV electron beam with peak brightness somewhat better than that achieved in S-band photoinjectors, such as the one developed for the Linac Coherent Light Source (LCLS). The X-band rfmore » gun operates with up to a 200 MV/m peak field on the cathode, and has been used to produce bunches of a few pC to 1.2 nC in charge. Notably, bunch lengths as short as 120 fs rms have been measured for charges of 5 pC (~3×10 7 electrons), and normalized transverse emittances as small as 0.22 mm-mrad have been measured for this same charge level. Bunch lengths as short as 400 (250) fs rms have been achieved for electron bunches of 100 (20) pC with transverse normalized emittances of 0.7 (0.35) mm-mrad. As a result, we report on the performance and the lessons learned from the operation and optimization of this first generation X-band gun.« less

  10. Examining the relationship between the prevalence of guns and homicide rates in the USA using a new and improved state-level gun ownership proxy.

    PubMed

    Siegel, Michael; Ross, Craig S; King, Charles

    2014-12-01

    Determining the relationship between gun ownership levels and firearm homicide rates is critical to inform public health policy. Previous research has shown that state-level gun ownership, as measured by a widely used proxy, is positively associated with firearm homicide rates. A newly developed proxy measure that incorporates the hunting license rate in addition to the proportion of firearm suicides correlates more highly with state-level gun ownership. To corroborate previous research, we used this new proxy to estimate the association of state-level gun ownership with total, firearm, and non-firearm homicides. Using state-specific data for the years 1981-2010, we modelled these rates as a function of gun ownership level, controlling for potential confounding factors. We used a negative binomial regression model and accounted for clustering of observations among states. We found that state-level gun ownership as measured by the new proxy, is significantly associated with firearm and total homicides but not with non-firearm homicides. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  11. Frequency of Guns in the Households of High School Seniors

    ERIC Educational Resources Information Center

    Coker, Ann L.; Bush, Heather M.; Follingstad, Diane R.; Brancato, Candace J.

    2017-01-01

    Background: In 2013, President Obama lifted the federal ban on gun violence research. The current study provides one of the first reports to estimate household gun ownership as reported by youth. Methods: In this cohort study of 3,006 high school seniors from 24 schools, we examined the frequency of household guns ownership. Results: About 65%…

  12. Spatio-temporal patterns of gun violence in Syracuse, New York 2009-2015.

    PubMed

    Larsen, David A; Lane, Sandra; Jennings-Bey, Timothy; Haygood-El, Arnett; Brundage, Kim; Rubinstein, Robert A

    2017-01-01

    Gun violence in the United States of America is a large public health problem that disproportionately affects urban areas. The epidemiology of gun violence reflects various aspects of an infectious disease including spatial and temporal clustering. We examined the spatial and temporal trends of gun violence in Syracuse, New York, a city of 145,000. We used a spatial scan statistic to reveal spatio-temporal clusters of gunshots investigated and corroborated by Syracuse City Police Department for the years 2009-2015. We also examined predictors of areas with increased gun violence using a multi-level zero-inflated Poisson regression with data from the 2010 census. Two space-time clusters of gun violence were revealed in the city. Higher rates of segregation, poverty and the summer months were all associated with increased risk of gun violence. Previous gunshots in the area were associated with a 26.8% increase in the risk of gun violence. Gun violence in Syracuse, NY is both spatially and temporally stable, with some neighborhoods of the city greatly afflicted.

  13. Spatio-temporal patterns of gun violence in Syracuse, New York 2009-2015

    PubMed Central

    Lane, Sandra; Jennings-Bey, Timothy; Haygood-El, Arnett; Brundage, Kim; Rubinstein, Robert A.

    2017-01-01

    Gun violence in the United States of America is a large public health problem that disproportionately affects urban areas. The epidemiology of gun violence reflects various aspects of an infectious disease including spatial and temporal clustering. We examined the spatial and temporal trends of gun violence in Syracuse, New York, a city of 145,000. We used a spatial scan statistic to reveal spatio-temporal clusters of gunshots investigated and corroborated by Syracuse City Police Department for the years 2009–2015. We also examined predictors of areas with increased gun violence using a multi-level zero-inflated Poisson regression with data from the 2010 census. Two space-time clusters of gun violence were revealed in the city. Higher rates of segregation, poverty and the summer months were all associated with increased risk of gun violence. Previous gunshots in the area were associated with a 26.8% increase in the risk of gun violence. Gun violence in Syracuse, NY is both spatially and temporally stable, with some neighborhoods of the city greatly afflicted. PMID:28319125

  14. Finite element analyses of a linear-accelerator electron gun

    NASA Astrophysics Data System (ADS)

    Iqbal, M.; Wasy, A.; Islam, G. U.; Zhou, Z.

    2014-02-01

    Thermo-structural analyses of the Beijing Electron-Positron Collider (BEPCII) linear-accelerator, electron gun, were performed for the gun operating with the cathode at 1000 °C. The gun was modeled in computer aided three-dimensional interactive application for finite element analyses through ANSYS workbench. This was followed by simulations using the SLAC electron beam trajectory program EGUN for beam optics analyses. The simulations were compared with experimental results of the assembly to verify its beam parameters under the same boundary conditions. Simulation and test results were found to be in good agreement and hence confirmed the design parameters under the defined operating temperature. The gun is operating continuously since commissioning without any thermal induced failures for the BEPCII linear accelerator.

  15. Finite element analyses of a linear-accelerator electron gun.

    PubMed

    Iqbal, M; Wasy, A; Islam, G U; Zhou, Z

    2014-02-01

    Thermo-structural analyses of the Beijing Electron-Positron Collider (BEPCII) linear-accelerator, electron gun, were performed for the gun operating with the cathode at 1000 °C. The gun was modeled in computer aided three-dimensional interactive application for finite element analyses through ANSYS workbench. This was followed by simulations using the SLAC electron beam trajectory program EGUN for beam optics analyses. The simulations were compared with experimental results of the assembly to verify its beam parameters under the same boundary conditions. Simulation and test results were found to be in good agreement and hence confirmed the design parameters under the defined operating temperature. The gun is operating continuously since commissioning without any thermal induced failures for the BEPCII linear accelerator.

  16. Energy partitioning in an inductively driven rail gun

    NASA Technical Reports Server (NTRS)

    Sen, K. K.; Ray, P. K.

    1984-01-01

    The equations describing the performance of an inductively driven rail are analyzed numerically. Friction between the projectile and rails is included through an empirical formulation. The equations are applied to the experiment of Rashleigh and Marshall to obtain an estimate of energy distribution in rail guns as a function of time. It is found that only 15 percent of energy delivered by the inductor to the gun is transformed into the kinetic energy of the projectile. This study provides an insight into the nature of nonlinear coupling involved in the electromechanical interactions in a rail gun.

  17. The Baltimore Youth Ammunition Initiative: A Model Application of Local Public Health Authority in Preventing Gun Violence

    PubMed Central

    Lewin, Nancy L.; Vernick, Jon S.; Beilenson, Peter L.; Mair, Julie S.; Lindamood, Melisa M.; Teret, Stephen P.; Webster, Daniel W.

    2005-01-01

    In 2002, the Baltimore City Health Department, in collaboration with the Baltimore Police Department and the Johns Hopkins Center for Gun Policy and Research, launched the Youth Ammunition Initiative. The initiative addressed Baltimore’s problem of youth gun violence by targeting illegal firearm ammunition sales to the city’s young people. The initiative included undercover “sting” investigations of local businesses and issuance of health department violation and abatement notices. Intermediate results included the passage of 2 Baltimore city council ordinances regulating ammunition sales and reducing the number of outlets eligible to sell ammunition. Although it is too early to assess effects on violent crime, the intervention could theoretically reduce youth violence by interrupting one source of ammunition to youths. More important, the initiative can serve as a policy model for health commissioners seeking to become more active in gun violence prevention efforts. PMID:15855448

  18. The Transmission of Gun and Other Weapon-Involved Violence Within Social Networks

    PubMed Central

    Tracy, Melissa; Braga, Anthony A.; Papachristos, Andrew V.

    2016-01-01

    Fatal and nonfatal injuries resulting from gun violence remain a persistent problem in the United States. The available research suggests that gun violence diffuses among people and across places through social relationships. Understanding the relationship between gun violence within social networks and individual gun violence risk is critical in preventing the spread of gun violence within populations. This systematic review examines the existing scientific evidence on the transmission of gun and other weapon-related violence in household, intimate partner, peer, and co-offending networks. Our review identified 16 studies published between 1996 and 2015 that suggest that exposure to a victim or perpetrator of violence in one's interpersonal relationships and social networks increases the risk of individual victimization and perpetration. Formal network analyses find high concentrations of gun violence in small networks and that exposure to gun violence in one's networks is highly correlated with one's own probability of being a gunshot victim. Physical violence by parents and weapon use by intimate partners also increase risk for victimization and perpetration. Additional work is needed to better characterize the mechanisms through which network exposures increase individual risk for violence and to evaluate interventions aimed at disrupting the spread of gun and other weapon violence in high-risk social networks. PMID:26733492

  19. College Students Opinions on Gun Violence.

    PubMed

    Lewis, Rhonda K; LoCurto, Jamie; Brown, Kyrah; Stowell, David; Maryman, J'Vonnah; Dean, Amber; McNair, Thoi; Ojeda, Debbie; Siwierka, Julia

    2016-06-01

    Gun violence and control issues have become serious public health problems. This study gathered the opinions from 419 college students from a Midwestern University. Participants were asked about beliefs about purchasing assault weapons, beliefs about bringing handguns to college campuses and beliefs about contributing factors that lead to gun violence. Participants completed surveys online. The findings showed that overall 54 % of respondents believed that military assault weapons should be banned and 53 % agree that teachers should be allowed to carry a registered handgun on campus. There were statistically significant differences between males and females on these issues. For instance, females believed military assault weapons and high capacity magazines should be banned more than 1.9 times (p = .004) p < .05 compared to male students. On the other hand, female students were more likely to believe that school teachers should be allowed to carry registered handguns on school campuses more than 1.55 times (p = .046) p < .05 compared to their male student counterparts. There were no statistically significant differences between ethnic groups. The top four contributing factors that students believed led to gun violence were decline in parenting and family values (17 %), gang involvement (14 %), bullying (13.8 %) and guns being easy to obtain (13.8 %). Limitations and implications for policy work are discussed.

  20. Selling a gun to a stranger without a background check: acceptable behaviour?

    PubMed

    Hemenway, David; Azrael, Deborah; Miller, Matthew

    2018-06-01

    One way that guns get into the wrong hands is via gun sales without a background check. While the large majority of Americans support laws requiring universal background checks, no prior study has assessed whether Americans think it is acceptable behaviour to sell a gun to a stranger without a background check, whether or not there is a law against it. We sponsored a nationally representative survey of over 3900 American adults, oversampling gun owners, using an online panel provided by the survey firm Growth for Knowledge. Over 72% of American adults agree or strongly agree with the statement that 'whether it is legal or not, it is NOT acceptable to sell a gun to a stranger without a background check' and 11% disagree or strongly disagree. Subgroups less likely to agree are young adults, men, conservatives, those with less than a high school education and gun owners. Reducing the number of guns sold without a background check could help reduce the flow of guns to felons. Changes in normative attitudes and behaviours, as well as changes in law, could help accomplish this goal. Most Americans, including gun owners, believe selling a gun to a stranger without a background check is not acceptable behaviour. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Parallel 3D Finite Element Numerical Modelling of DC Electron Guns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prudencio, E.; Candel, A.; Ge, L.

    2008-02-04

    In this paper we present Gun3P, a parallel 3D finite element application that the Advanced Computations Department at the Stanford Linear Accelerator Center is developing for the analysis of beam formation in DC guns and beam transport in klystrons. Gun3P is targeted specially to complex geometries that cannot be described by 2D models and cannot be easily handled by finite difference discretizations. Its parallel capability allows simulations with more accuracy and less processing time than packages currently available. We present simulation results for the L-band Sheet Beam Klystron DC gun, in which case Gun3P is able to reduce simulation timemore » from days to some hours.« less

  2. Low-energy plasma-cathode electron gun with a perforated emission electrode

    NASA Astrophysics Data System (ADS)

    Burdovitsin, Victor; Kazakov, Andrey; Medovnik, Alexander; Oks, Efim; Tyunkov, Andrey

    2017-11-01

    We describe research of influence of the geometric parameters of perforated electrode on emission parameters of a plasma cathode electron gun generating continuous electron beams at gas pressure 5-6 Pa. It is shown, that the emission current increases with increasing the hole diameters and decreasing the thickness of the perforated emission electrode. Plasma-cathode gun with perforated electron can provide electron extraction with an efficiency of up to 72 %. It is shown, that the current-voltage characteristic of the electron gun with a perforated emission electrode differs from that of similar guns with fine mesh grid electrode. The plasma-cathode electron gun with perforated emission electrode is used for electron beam welding and sintering.

  3. FEATURE 1, SMALL GUN POSITION, VIEW FACING NORTH. Naval ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FEATURE 1, SMALL GUN POSITION, VIEW FACING NORTH. - Naval Air Station Barbers Point, Anti-Aircraft Battery Complex-Small Gun Position, East of Coral Sea Road, northwest of Hamilton Road, Ewa, Honolulu County, HI

  4. Non-solenoidal Plasma Startup in the Pegasus Toroidal Experiment

    NASA Astrophysics Data System (ADS)

    Sontag, Aaron

    2008-11-01

    Non-solenoidal (NS) startup will simplify the design of future tokamaks by eliminating need for a central solenoid and is required for an ST based CTF. In Pegasus, washer-stack current sources (plasma guns) are used to initiate NS discharges via point-source DC helicity injection. Current injected parallel to the helical vacuum field can relax into a tokamak-like configuration with toroidally-averaged closed flux and tokamak-like confinement. This requires no modification of the vacuum vessel and is scalable to fusion grade systems with proper geometry. Guns in the divertor region create discharges with Ip up to 50 kA, 3 times the vacuum windup. Nonlinear 3D simulation with NIMROD shows excitation of a line-tied kink, producing poloidal flux amplification. Evidence of flux amplification includes: reversal of edge poloidal magnetic flux; Ip increase over vacuum geometric windup; plasma position subject to radial force balance; and persistence of Ip after gun shut-off. Equilibria show high edge current (li = 0.2) and elevated q (qmin> 6), allowing access to high IN (IN> 12). Guns at the outboard midplane produce Ip up to 7 times the vacuum windup with large n=1 activity when edge q passes through rational surfaces. Line averaged density up to 2x10^19 m-3 after relaxation shows an increase in particle confinement over non-relaxed cases. Maximum Ip is determined by helicity and radial force balance, tokamak stability, and Taylor relaxation. Coupling midplane gun discharges to other CD is straightforward due to Ip decay times >3 ms. Poloidal field induction has been used to create NS discharges up to 80 kA and gun plasmas with Ip of 60 kA have been ramped to over 100 kA by including OH drive. Present research is aimed at understanding the physics of this technique in order to form NS targets in excess of 200 kA and design NS startup systems for larger devices.

  5. Effect of Gun Carrying on Perceptions of Risk Among Adolescent Offenders.

    PubMed

    Loughran, Thomas A; Reid, Joan A; Collins, Megan Eileen; Mulvey, Edward P

    2016-02-01

    We observed how perceptions of risks, costs, crime rewards, and violence exposure change as individual gun-carrying behavior changes among high-risk adolescents. We analyzed a longitudinal study (2000-2010) of serious juvenile offenders in Maricopa County, Arizona, or Philadelphia County, Pennsylvania, assessing within-person changes in risk and reward perceptions, and violence exposure as individuals initiated or ceased gun carrying. Despite being associated with heightened exposure to violence, gun carrying was linked to lower perceptions of risks and costs and higher perceived rewards of offending. Gun carrying was not time-stable, as certain individuals both started and stopped carrying during the study. Within-person changes in carrying guns were associated with shifting perceptions of risks, costs, and rewards of crime, and changes in exposure to violence in expected directions. Gun carrying reduces perceptions of risks associated with offending while increasing actual risk of violence exposure. This suggests that there is an important disconnect between perceptions and objective levels of safety among high-risk youths. Gun-carrying decisions may not only be influenced by factors of protection and self-defense, but also by perceptions of risks and reward associated with engaging in crime more generally.

  6. Hand injury with a nail gun: a case report with literature review.

    PubMed

    Boya, Hakan; Uzun, Belkan

    2015-01-01

    The nail gun was introduced in the late 1950s to increase the ease of driving nails, studs, bolts, or staples into various hard surfaces. The nail gun is a potentially dangerous device that is still commonly used in the construction industry. Since its introduction, an increasing number of studies have reported injuries associated with nail guns. Nail gun-related injuries-such as to the head, neck, and chest-can be devastating, and in some cases, even fatal. Extremity injuries, notably in the hand, can cause loss of function, missed work, and long-term health effects. This case report describes a nail-gun injury of the hand along with a discussion of the unique features of and treatment strategies for nail gun injuries.

  7. High-perveance W-band Sheet-beam Electron Gun Design

    DTIC Science & Technology

    2008-04-01

    APR 2008 2. REPORT TYPE 3. DATES COVERED 00-00-2008 to 00-00-2008 4. TITLE AND SUBTITLE High -perveance W- band Sheet-beam Electron Gun Design 5a...8-98) Prescribed by ANSI Std Z39-18 10.1: High -perveance W- band Sheet-beam Electron Gun Design Khanh T. Nguyen1, John Pasour, Edward L. Wright1...effects due to cathode temperature are also included in the simulation. Keywords: Sheet beam; W- band ; electron gun; high perveance; amplifiers

  8. Thermal analysis of electron gun for travelling wave tubes

    NASA Astrophysics Data System (ADS)

    Bhat, K. S.; Sreedevi, K.; Ravi, M.

    2006-11-01

    Thermal analysis of a pierce type electron gun using the FEM software ANSYS and its experimental validation are presented in this paper. Thermal analysis of the electron gun structure has been carried out to find out the effect of heater power on steady state temperature and warm-up time. The thermal drain of the supporting structure has also been analyzed for different materials. These results were experimentally verified in an electron gun. The experimental results closely match the ANSYS results.

  9. Gated Field-Emission Cathode Radio-Frequency (RF) Gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fermi Research Alliance, Fermi Alliance

    The goal of this CRADA was to procure the carbon nanotube cathode from Radiabeam, install it in HBESL and make current measurements as a function of the gun gradient. The gun was operated at 1.3 GHz. After testing, send the cathode back to RadiaBeam for surface analysis.

  10. Construction and Test of a Novel Superconducting RF Electron gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bisognano, Joseph J.

    The University of Wisconsin-Madison has completed installation of a superconducting electron gun. Its concept was optimized to be the source for a CW free electron laser facility with multiple megahertz repetition rate end stations. This VHF superconducting configuration holds the promise of the highest performance for CW injectors. Initial commissioning efforts show that the cavity can achieve gradients of 35 MV/m at the cathode position. With the cathode inserted CW operation has been achieved at 20 MV/m with good control of microphonics, negligible dark current, and Q0 > 3×109 at 4 K. Bunch charges of ~100 pC have been delivered,more » and first simple beam measurements made. These preliminary results are very encouraging for production of 100s pC bunches with millimeter-milliradian or smaller normalized emittances. Plans are in place to carry out more definitive studies to establish the full capabilities. However, since the grant was not renewed, the electron gun is currently mothballed, and without supplemental fund the opportunity for further work will be lost.« less

  11. Firearm Retailers’ Willingness to Participate in an Illegal Gun Purchase

    PubMed Central

    2010-01-01

    Firearm-related violence is a significant public health and public safety problem for cities in the USA, and licensed firearm retailers are an important source of the guns used in that violence. Using a scripted telephone interview, we screened a sample of licensed retailers in California to assess their willingness to participate in the surrogate or “straw” purchase of a handgun; such purchases are illegal under federal law. Of 149 retailers who provided a response, 30 (20.1%) agreed to participate. In multivariate analysis, pawnbrokers were more likely to agree than were gun dealers (odds ratio 6.58, 95% confidence interval 1.99–21.71). Sales of handguns that were later subjected to ownership tracing (a proxy measure for a gun’s use in crime) were not more frequent among retailers who agreed to participate than among others, and other findings were unexpected as well. Electronic supplementary material The online version of this article (doi:10.1007/s11524-010-9489-6) contains supplementary material, which is available to authorized users. PMID:20803095

  12. FEATURE A. CONCRETE ANTIAIRCRAFT GUN POSITION, VIEW FACING NORTHNORTHEAST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FEATURE A. CONCRETE ANTI-AIRCRAFT GUN POSITION, VIEW FACING NORTH-NORTHEAST. - Naval Air Station Barbers Point, Battery-Anti-Aircraft Gun Position, South of Point Cruz Road & west of Coral Sea Road, Ewa, Honolulu County, HI

  13. Gun Safety (For Parents)

    MedlinePlus

    ... Kids Teens How Media Use Affects Your Child School Violence and the News How to Talk to Your ... What Should I Do? Should You Worry About School Violence? Gun Safety Posttraumatic Stress Disorder View more About ...

  14. Ways to Increase Launch Velocities of 2-Stage Gas Guns

    NASA Technical Reports Server (NTRS)

    Bogdanoff, David W.; Cambier, Jean-Luc; Arnold, James O. (Technical Monitor)

    1994-01-01

    velocity can be obtained with multiple compressions in the pump tube. With a conventional two-stage gun, an important limitation to obtaining higher velocities is friction and heat transfer to the barrel, which typically has a length- to- diameter ratio of 200-400. These viscous losses greatly reduce the effectiveness of the regions of the barrel far removed from the second stage breech. We have studied computationally the effect of adding an additional breech (or breeches) along the barrel to reduce these viscous losses. Velocity increases from 6.5 to 7.2 km/sec have been obtained using the main breech and one additional breech. In these results, both breeches were operated with hydrogen, heated electrothermally. We have also studied a gun geometry where the main breech is operated in the conventional manner, using piston compression. The additional breech is operated either with electrothermal heating or heating by using a high explosive charge in a novel geometry. The latter option provides very effective compression, heating and acceleration of the hydrogen working gas and is fully reusable. Calculations are presented which show that very substantial increases in muzzle velocity can be obtained this way, without overstressing the projectile or the 'gun. The third technique studied is to add a section of ram accelerator tube after the barrel to further accelerate the projectile. The ram accelerator used here is not the conventional premixed gas ram accelerator, but a new technique using high explosive as the energy source and pure hydrogen as the working gas in a geometry which can be made fully reusable. Preliminary results with this new rain accelerator geometry were presented and showed that stable ram accelerator drive can be established. Herein, detailed calculations axe presented which show that substantial velocity increases can be obtained using this ram accelerator technique in tandem with a conventional light gas gun.

  15. The Origins of Gun Culture in the United States, 1760-1865.

    ERIC Educational Resources Information Center

    Bellesiles, Michael A.

    1996-01-01

    Maintains that, counter to popular opinion, guns played no significant role in U.S. frontier life until the Civil War era. Evidence from probate and militia records reveal a consistent lack of gun ownership while magazine articles painted unflattering portraits of gun ownership and hunting. Discusses reasons for the change. (MJP)

  16. Compact Electron Gun Based on Secondary Emission Through Ionic Bombardment

    PubMed Central

    Diop, Babacar; Bonnet, Jean; Schmid, Thomas; Mohamed, Ajmal

    2011-01-01

    We present a new compact electron gun based on the secondary emission through ionic bombardment principle. The driving parameters to develop such a gun are to obtain a quite small electron gun for an in-flight instrument performing Electron Beam Fluorescence measurements (EBF) on board of a reentry vehicle in the upper atmosphere. These measurements are useful to characterize the gas flow around the vehicle in terms of gas chemical composition, temperatures and velocity of the flow which usually presents thermo-chemical non-equilibrium. Such an instrument can also be employed to characterize the upper atmosphere if placed on another carrier like a balloon. In ground facilities, it appears as a more practical tool to characterize flows in wind tunnel studies or as an alternative to complex electron guns in industrial processes requiring an electron beam. We describe in this paper the gun which has been developed as well as its different features which have been characterized in the laboratory. PMID:22163896

  17. FEATURE A. CONCRETE ANTIAIRCRAFT GUN POSITION, VIEW FACING NORTH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FEATURE A. CONCRETE ANTI-AIRCRAFT GUN POSITION, VIEW FACING NORTH - NORTHEAST (with scale stick). - Naval Air Station Barbers Point, Battery-Anti-Aircraft Gun Position, South of Point Cruz Road & west of Coral Sea Road, Ewa, Honolulu County, HI

  18. The synthesis method for design of electron flow sources

    NASA Astrophysics Data System (ADS)

    Alexahin, Yu I.; Molodozhenzev, A. Yu

    1997-01-01

    The synthesis method to design a relativistic magnetically - focused beam source is described in this paper. It allows to find a shape of electrodes necessary to produce laminar space charge flows. Electron guns with shielded cathodes designed with this method were analyzed using the EGUN code. The obtained results have shown the coincidence of the synthesis and analysis calculations [1]. This method of electron gun calculation may be applied for immersed electron flows - of interest for the EBIS electron gun design.

  19. Effects of Maryland's law banning Saturday night special handguns on crime guns

    PubMed Central

    Vernick, J.; Webster, D.; Hepburn, L.

    1999-01-01

    Objectives—To determine the effects of a 1988 Maryland law that banned "Saturday night special" handguns on the types of guns used in crime. To determine if controls on the lawful market for handguns affect the illegal market as well. Setting—Baltimore, Maryland, and 15 other US cities participating in a crime gun tracing project. Methods—Cross sectional comparison of the proportion of crime guns that are banned by the Maryland law, comparing Baltimore, MD with 15 other cities outside of Maryland. Multivariate linear regression analysis to determine if observed differences between Baltimore and 15 other cities are explained by demographic or regional differences among the cities rather than Maryland's law. Results—Among crime guns, a gun banned by Maryland's law is more than twice as likely (relative risk (RR) 2.3, 95% confidence interval (CI) 2.0 to 2.5) to be the subject of a crime gun trace request in 15 other cities combined, than in Baltimore. Among homicide guns, a crime especially relevant for public safety, a comparable difference (RR 2.1, 95% CI 1.1 to 4.2) was observed. The proportion of Baltimore's crime guns that are banned is 12 percentage points lower than would be expected based on its demographic and regional characteristics alone. Among crime guns purchased after 1990, a much smaller proportion in Baltimore are banned models than in 15 other cities. Conclusions—Maryland's law has reduced the use of banned Saturday night specials by criminals in Baltimore. Contrary to the claims of some opponents of gun control laws, regulation of the lawful market for firearms can also affect criminals. PMID:10628912

  20. The Transmission of Gun and Other Weapon-Involved Violence Within Social Networks.

    PubMed

    Tracy, Melissa; Braga, Anthony A; Papachristos, Andrew V

    2016-01-01

    Fatal and nonfatal injuries resulting from gun violence remain a persistent problem in the United States. The available research suggests that gun violence diffuses among people and across places through social relationships. Understanding the relationship between gun violence within social networks and individual gun violence risk is critical in preventing the spread of gun violence within populations. This systematic review examines the existing scientific evidence on the transmission of gun and other weapon-related violence in household, intimate partner, peer, and co-offending networks. Our review identified 16 studies published between 1996 and 2015 that suggest that exposure to a victim or perpetrator of violence in one's interpersonal relationships and social networks increases the risk of individual victimization and perpetration. Formal network analyses find high concentrations of gun violence in small networks and that exposure to gun violence in one's networks is highly correlated with one's own probability of being a gunshot victim. Physical violence by parents and weapon use by intimate partners also increase risk for victimization and perpetration. Additional work is needed to better characterize the mechanisms through which network exposures increase individual risk for violence and to evaluate interventions aimed at disrupting the spread of gun and other weapon violence in high-risk social networks. © The Author 2016. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. Gun control saves lives.

    PubMed

    Matzopoulos, Richard

    2016-05-19

    Reducing firearm mortality by means of stricter gun control is one of the most important short- to medium-term measures to address the burden of violence in South Africa, while longer-term interventions and policy measures take effect.

  2. Modification of anisotropic plasma diffusion via auxiliary electrons emitted by a carbon nanotubes-based electron gun in an electron cyclotron resonance ion source.

    PubMed

    Malferrari, L; Odorici, F; Veronese, G P; Rizzoli, R; Mascali, D; Celona, L; Gammino, S; Castro, G; Miracoli, R; Serafino, T

    2012-02-01

    The diffusion mechanism in magnetized plasmas is a largely debated issue. A short circuit model was proposed by Simon, assuming fluxes of lost particles along the axial (electrons) and radial (ions) directions which can be compensated, to preserve the quasi-neutrality, by currents flowing throughout the conducting plasma chamber walls. We hereby propose a new method to modify Simon's currents via electrons injected by a carbon nanotubes-based electron gun. We found this improves the source performances, increasing the output current for several charge states. The method is especially sensitive to the pumping frequency. Output currents for given charge states, at different auxiliary electron currents, will be reported in the paper and the influence of the frequency tuning on the compensation mechanism will be discussed.

  3. Coaxial Plasma Gun Development for the ARPA-E PLX- α Project

    NASA Astrophysics Data System (ADS)

    Witherspoon, F. Douglas; Case, Andrew; Brockington, Samuel

    2015-11-01

    We describe the renewed effort to design and build coaxial plasma guns appropriate for a scaling study of spherically imploding plasma liners as a standoff magneto-inertial-fusion driver under the ARPA-E Accelerating Low-Cost Plasma Heating And Assembly (ALPHA) program. HyperV joins LANL, UAH, UNM, BNL, and Tech-X to develop, build, operate and analyze a 60 plasma gun experiment using the existing PLX facility at LANL. The guns will be designed to operate over a scaling range of operating parameters: 0.5-5.0 mg of Ar, Ne, N2, Kr, and Xe; 20-60 km/s; 1016 -1017 cm-3 muzzle density; and up to 7.5 kJ stored energy per gun. Each gun is planned to incorporate contoured gaps, fast dense gas injection and triggering, and innovative integral sparkgap switching and pfn configurations to reduce inductance, cost, and complexity, and to increase efficiency and system reliability. We will describe the overall design approach for the guns and pulsed power systems. This work supported by the ARPA-E ALPHA Program.

  4. Possible application of electromagnetic guns to impact fusion

    NASA Astrophysics Data System (ADS)

    Kostoff, R. N.; Peaslee, A. T., Jr.; Ribe, F. L.

    1982-01-01

    The possible application of electromagnetic guns to impact fusion for the generation of electric power is discussed, and advantages of impact fusion over the more conventional inertial confinement fusion concepts are examined. It is shown that impact fusion can achieve the necessary high yields, of the order of a few gigajoules, which are difficult to achieve with lasers except at unrealistically high target gains. The rail gun accelerator is well adapted to the delivery of some 10-100 megajoules of energy to the fusion target, and the electrical technology involved is relatively simple: inductive storage or rotating machinery and capacitors. It is concluded that the rail gun has the potential of developing into an impact fusion macroparticle accelerator.

  5. High Velocity Gas Gun

    NASA Technical Reports Server (NTRS)

    1988-01-01

    A video tape related to orbital debris research is presented. The video tape covers the process of loading a High Velocity Gas Gun and firing it into a mounted metal plate. The process is then repeated in slow motion.

  6. Preliminary Guidelines for Safe and Effective Use of Hot, High-Pressure Washers for Maintenance Cleaning of Army Vehicles.

    DTIC Science & Technology

    1982-11-01

    26AS TACT (Ctbm onrols st N 19m4i60M, = de IdIM b o1ck numbef) - >While hot, high-pressure washers clean effectively, they can also damage parts on Army...conserve water resources, and reduce the costs of wastewater treatment. The objec- At most Army installations, maintenance cleaning tive of the phase of...Itios Catalog Code 214. Posary not only to control the parameters involved for a more accurate assessment of the potential for damage. 2R. I de ~cia

  7. A new design of indirectly heated cathode based strip type electron gun.

    PubMed

    Maiti, Namita; Lijeesh, K; Barve, U D; Quadri, Nishad; Tembhare, G U; Mukherjee, S; Thakur, K B; Das, A K

    2013-08-01

    A new design of indirectly heated solid cathode based electron gun (200 kW, 45 kV, 270° bent strip type electron gun) has been presented. The design issue addressed is the uniformity of temperature on the solid cathode using (a) a multi-segmented filament with variable height as the primary heat source and (b) trapezoidal shaped single long filament as the primary heat source. The proposed design in this paper is based on computer simulation and validated by extensive experimentations. The design emphasis is on maintaining uniform temperature on the solid cathode. The designed multi-segment filament and the single long filament provide a temperature uniformity on the solid cathode of about 250 K and 110 K, respectively. The better temperature uniformity inspite of the thermal expansion, in case of a single long filament tightly clamped at two ends, has been possible due to shaping of the single filament with a number of constituent sections such that the thermal expansion of different sections forming the actual filament takes care of not only the mechanical stability but also does not affect the emitting surface of the filament. Experiments show that the modified design achieves a one to one correspondence of the solid cathode length and the electron beam length emitted from the solid cathode.

  8. Gun Possession among Massachusetts Batterer Intervention Program Enrollees

    ERIC Educational Resources Information Center

    Rothman, Emily F.; Johnson, Renee M.; Hemenway, David

    2006-01-01

    Batterers with access to firearms present a serious lethal threat to their partners. The purpose of this exploratory study is to estimate the prevalence of and risk markers for gun possession among Massachusetts men enrolled in batterer intervention programs. The authors found that 1.8% of the men reported having a gun in or around their home.…

  9. The progress of funnelling gun high voltage condition and beam test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, E.; Ben-Zvi, I.; Gassner, D. M.

    A prototype of a high average current polarized electron funneling gun as an eRHIC injector has been built at BNL. The gun was assembled and tested at Stangenes Incorporated. Two beams were generated from two GaAs photocathodes and combined by a switched combiner field. We observed the combined beams on a YAG crystal and measured the photocurrent by a Faraday cup. The gun has been shipped to Stony Brook University and is being tested there. In this paper we will describe the major components of the gun and recent beam test results. High voltage conditioning is discussed as well.

  10. Nerf gun eye injuries: traumatic hyphema.

    PubMed

    Bizrah, Mukhtar; Verma, Seema

    2017-09-18

    Three unrelated patients attended the accident and emergency department with pain and blurred vision after ocular injury with a Nerf gun. Two were adults and one was a child, all of which presented within a 3 months' period. All three cases were found to have ≥1 mm of traumatic hyphema (pooling of blood in anterior chamber of the eye), indicating significant ocular trauma. The two adult patients had formed hyphema and uveitis. The 11-year-old child had formed hyphema, corneal oedema, anterior uveitis, localised angle recession and commotio retinae, which further highlight the severity of the ocular trauma. Significant Nerf gun ocular injuries are not reported in the literature, as far as we know. This case series serves to raise awareness of the seriousness of Nerf gun ocular injuries. It encourages further exploration of reasons for such injuries, as well as a review of protective measures against ocular trauma. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. Media Agenda Setting Regarding Gun Violence before and after a Mass Shooting.

    PubMed

    Jashinsky, Jared Michael; Magnusson, Brianna; Hanson, Carl; Barnes, Michael

    2016-01-01

    Gun violence is related to substantial morbidity and mortality with surrounding discussions framed and shaped by the media. This study's objective was to explore national news media's reporting of gun violence around a mass shooting. National news pieces were coded according to categories of gun violence, media frames, entities held responsible, responses, and reporting of the public heath approach. Individuals were held responsible for gun violence in 63% of pieces before and 32% after the shooting. Lawmakers were held responsible in 30% of pieces before and 66% after. Background checks were a proposed gun violence prevention method in 18% of pieces before and 55% after Sandy Hook, and lethality reduction of firearms was in 9% before and 57% after. Following a mass shooting, the media tended to hold government, not individuals, primarily responsible. The media often misrepresented the real picture of gun violence and key public health roles.

  12. Gun Dealers, USA.

    ERIC Educational Resources Information Center

    Duker, Laurie; And Others

    In the United States, more than 11,500 adolescents' and young adults' lives are taken each year by firearms. Although Federal law prohibits minors from purchasing handguns, they typically get them by asking someone of legal age (18 years or older) to purchase them from one of the 256,771 Federally licensed gun dealers. This pamphlet answers…

  13. Unusual blunt force wound produced by a gun muzzle.

    PubMed

    Hanzlick, R; Zaki, S A

    1986-09-01

    Most blunt force injuries produced by guns are associated with gun butts, and patterned, muzzle/sight impressions are usually produced by discharging firearms. An unusual and distinct forehead laceration produced by a blow with the muzzle end of a .32 caliber revolver is presented.

  14. Optimization Study of the Ames 0.5 Two-Stage Light Gas Gun

    NASA Technical Reports Server (NTRS)

    Bogdanoff, D. W.

    1996-01-01

    There is a need for more faithful simulation of space debris impacts on various space vehicles. Space debris impact velocities can range up to 14 km/sec and conventional two-stage light gas guns with moderately heavy saboted projectiles are limited to launch velocities of 7-8 km/sec. Any increases obtained in the launch velocities will result in more faithful simulations of debris impacts. It would also be valuable to reduce the maximum gun and projectile base pressures and the gun barrel erosion rate. In this paper, the results of a computational fluid dynamics (CFD) study designed to optimize the performance of the NASA Ames 0.5' gun by systematically varying seven gun operating parameters are reported. Particularly beneficial effects were predicted to occur if (1) the piston mass was decreased together with the powder mass and the hydrogen fill pressure and (2) the pump tube length was decreased. The optimum set of changes in gun operating conditions were predicted to produce an increase in muzzle velocity of 0.7-1.0 km/sec, simultaneously with a substantial decrease in gun erosion. Preliminary experimental data have validated the code predictions. Velocities of up to 8.2 km/sec with a 0.475 cm diameter saboted aluminum sphere have been obtained, along with large reductions in gun erosion rates.

  15. Gas Gun Model and Comparison to Experimental Performance of Pipe Guns Operating with Light Propellant Gases and Large Cryogenic Pellets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reed, J. R.; Carmichael, J. R.; Gebhart, T. E.

    Injection of multiple large (~10 to 30 mm diameter) shattered pellets into ITER plasmas is presently part of the scheme planned to mitigate the deleterious effects of disruptions on the vessel components. To help in the design and optimize performance of the pellet injectors for this application, a model referred to as “the gas gun simulator” has been developed and benchmarked against experimental data. The computer code simulator is a Java program that models the gas-dynamics characteristics of a single-stage gas gun. Following a stepwise approach, the code utilizes a variety of input parameters to incrementally simulate and analyze themore » dynamics of the gun as the projectile is launched down the barrel. Using input data, the model can calculate gun performance based on physical characteristics, such as propellant-gas and fast-valve properties, barrel geometry, and pellet mass. Although the model is fundamentally generic, the present version is configured to accommodate cryogenic pellets composed of H2, D2, Ne, Ar, and mixtures of them and light propellant gases (H2, D2, and He). The pellets are solidified in situ in pipe guns that consist of stainless steel tubes and fast-acting valves that provide the propellant gas for pellet acceleration (to speeds ~200 to 700 m/s). The pellet speed is the key parameter in determining the response time of a shattered pellet system to a plasma disruption event. The calculated speeds from the code simulations of experiments were typically in excellent agreement with the measured values. With the gas gun simulator validated for many test shots and over a wide range of physical and operating parameters, it is a valuable tool for optimization of the injector design, including the fast valve design (orifice size and volume) for any operating pressure (~40 bar expected for the ITER application) and barrel length for any pellet size (mass, diameter, and length). Key design parameters and proposed values for the pellet

  16. Gas Gun Model and Comparison to Experimental Performance of Pipe Guns Operating with Light Propellant Gases and Large Cryogenic Pellets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Combs, S. K.; Reed, J. R.; Lyttle, M. S.

    2016-01-01

    Injection of multiple large (~10 to 30 mm diameter) shattered pellets into ITER plasmas is presently part of the scheme planned to mitigate the deleterious effects of disruptions on the vessel components. To help in the design and optimize performance of the pellet injectors for this application, a model referred to as “the gas gun simulator” has been developed and benchmarked against experimental data. The computer code simulator is a Java program that models the gas-dynamics characteristics of a single-stage gas gun. Following a stepwise approach, the code utilizes a variety of input parameters to incrementally simulate and analyze themore » dynamics of the gun as the projectile is launched down the barrel. Using input data, the model can calculate gun performance based on physical characteristics, such as propellant-gas and fast-valve properties, barrel geometry, and pellet mass. Although the model is fundamentally generic, the present version is configured to accommodate cryogenic pellets composed of H2, D2, Ne, Ar, and mixtures of them and light propellant gases (H2, D2, and He). The pellets are solidified in situ in pipe guns that consist of stainless steel tubes and fast-acting valves that provide the propellant gas for pellet acceleration (to speeds ~200 to 700 m/s). The pellet speed is the key parameter in determining the response time of a shattered pellet system to a plasma disruption event. The calculated speeds from the code simulations of experiments were typically in excellent agreement with the measured values. With the gas gun simulator validated for many test shots and over a wide range of physical and operating parameters, it is a valuable tool for optimization of the injector design, including the fast valve design (orifice size and volume) for any operating pressure (~40 bar expected for the ITER application) and barrel length for any pellet size (mass, diameter, and length). Key design parameters and proposed values for the pellet

  17. Compression-Ignition Sensitivity Studies of Liquid Propellants for Guns

    DTIC Science & Technology

    1979-07-01

    a -- h f m1 Report No. PCRL-F’.-75-004 July 1979 COMPRESSION-I=NITION SDNSITrI"Y STUDIES j? LIQUID PROPELLAhTS rOR GUNS Contract No. DAXK10-78-C-0315...Rmpression- qnition nsitivit 24AU7ud1ies,ś of Liquid Pr ielants or Guns # It) M~oehe BenReuven E6ad Martin ýumme rfielId - AAK10-78-C-0315/J 9...levels and pressurization rates comparable to .’iose of liquid propellant gun (LPG) systems, particularly during the start-up phase o-f the ballistic cycle

  18. Commentary: evidence to guide gun violence prevention in America.

    PubMed

    Webster, Daniel W

    2015-03-18

    Gun violence is a major threat to the public's health and safety in the United States. The articles in this volume's symposium on gun violence reveal the scope of the problem and new trends in mortality rates from gunfire. Leading scholars synthesize research evidence that demonstrates the ability of numerous policies and programs-each consistent with lessons learned from successful efforts to combat public health problems-to prevent gun violence. Each approach presents challenges to successful implementation. Future research should inform efforts to assess which approaches are most effective and how to implement evidence-based interventions most effectively.

  19. Improving firearm storage in Alaska native villages: a randomized trial of household gun cabinets.

    PubMed

    Grossman, David C; Stafford, Helen A; Koepsell, Thomas D; Hill, Ryan; Retzer, Kyla D; Jones, Ward

    2012-05-01

    We determined if the installation of gun cabinets improved household firearm storage practices. We used a wait list, randomized trial design with 2 groups. The "early" group received the intervention at baseline, and the "late" group received it at 12 months. Up to 2 gun cabinets were installed in each enrolled home, along with safety messages. In-person surveys were conducted at 12 and 18 months to determine the proportion of households reporting unlocked guns or ammunition. Direct observations of unlocked guns were also compared. At baseline, 93% of homes reported having at least 1 unlocked gun in the home, and 89% reported unlocked ammunition. At 12 months, 35% of homes in the early group reported unlocked guns compared with 89% in the late group (P < .001). Thirty-six percent of the early homes reported unlocked ammunition compared with 84% of late homes (P < .001). The prevalence of these storage practices was maintained at 18 months. Observations of unlocked guns decreased significantly (from 20% to 8%) between groups (P < .03). Gun cabinet installation in rural Alaskan households improved the storage of guns and ammunition. If these gains are sustained over time, it may lead to a reduction in gun-related injuries and deaths in this population.

  20. Secondary emission electron gun using external primaries

    DOEpatents

    Srinivasan-Rao, Triveni [Shoreham, NY; Ben-Zvi, Ilan [Setauket, NY

    2009-10-13

    An electron gun for generating an electron beam is provided, which includes a secondary emitter. The secondary emitter includes a non-contaminating negative-electron-affinity (NEA) material and emitting surface. The gun includes an accelerating region which accelerates the secondaries from the emitting surface. The secondaries are emitted in response to a primary beam generated external to the accelerating region. The accelerating region may include a superconducting radio frequency (RF) cavity, and the gun may be operated in a continuous wave (CW) mode. The secondary emitter includes hydrogenated diamond. A uniform electrically conductive layer is superposed on the emitter to replenish the extracted current, preventing charging of the emitter. An encapsulated secondary emission enhanced cathode device, useful in a superconducting RF cavity, includes a housing for maintaining vacuum, a cathode, e.g., a photocathode, and the non-contaminating NEA secondary emitter with the uniform electrically conductive layer superposed thereon.

  1. Secondary emission electron gun using external primaries

    DOEpatents

    Srinivasan-Rao, Triveni [Shoreham, NY; Ben-Zvi, Ilan [Setauket, NY; Kewisch, Jorg [Wading River, NY; Chang, Xiangyun [Middle Island, NY

    2007-06-05

    An electron gun for generating an electron beam is provided, which includes a secondary emitter. The secondary emitter includes a non-contaminating negative-electron-affinity (NEA) material and emitting surface. The gun includes an accelerating region which accelerates the secondaries from the emitting surface. The secondaries are emitted in response to a primary beam generated external to the accelerating region. The accelerating region may include a superconducting radio frequency (RF) cavity, and the gun may be operated in a continuous wave (CW) mode. The secondary emitter includes hydrogenated diamond. A uniform electrically conductive layer is superposed on the emitter to replenish the extracted current, preventing charging of the emitter. An encapsulated secondary emission enhanced cathode device, useful in a superconducting RF cavity, includes a housing for maintaining vacuum, a cathode, e.g., a photocathode, and the non-contaminating NEA secondary emitter with the uniform electrically conductive layer superposed thereon.

  2. Preventing Clogging In A Vacuum Plasma Spray Gun

    NASA Technical Reports Server (NTRS)

    Krotz, Phillip D.; Daniel, Ronald L., Jr.; Davis, William M.

    1994-01-01

    Modification of powder-injection ports enables lengthy, high-temperature deposition operations. Graphite inserts prevent clogging of ports through which copper powder injected into vacuum plasma spray (VPS) gun. Graphite liners eliminate need to spend production time refurbishing VPS gun, reducing cost of production and increasing productivity. Concept also applied to other material systems used for net-shape fabrication via VPS.

  3. Everyday Engineering: What Makes a Squirt Gun Squirt?

    ERIC Educational Resources Information Center

    Moyer, Richard; Everett, Susan

    2009-01-01

    You may not think of engineering and squirt guns in the same sentence. However, like many examples of engineering design, the squirt gun pump mechanism is uncomplicated, yet elegant, and very inexpensive to manufacture. The design is widely used because of its simplicity and low cost. With only a few moving parts, it is able to deliver a stream of…

  4. Los Alamos Guns Take Aim at Material's Mysteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Byers, Mark; Moore, David; Dimarino, Steve

    Los Alamos National Laboratory scientists and technicians conduct thousands of experiments a year, delving into the fundamental nature of everything from supernovas to subatomic particles. One set of instruments used to better understand the fundamental nature of various materials are 10 scientific gun systems that fire various projectiles at high-tech targets to create enormous velocities, pressures, and temperatures - and using laser, x-ray, and other diagnostics - explore the very nature of metals and other materials. The hundreds of gun-based experiments conducted every year at the Laboratory require a highly-skilled staff of scientists and technicians, and has given rise tomore » a special organization called the "gun working group" to foster open communications, cooperation, problem-solving, and a healthy safety culture.« less

  5. Los Alamos Guns Take Aim at Material's Mysteries

    ScienceCinema

    Byers, Mark; Moore, David; Dimarino, Steve

    2018-05-30

    Los Alamos National Laboratory scientists and technicians conduct thousands of experiments a year, delving into the fundamental nature of everything from supernovas to subatomic particles. One set of instruments used to better understand the fundamental nature of various materials are 10 scientific gun systems that fire various projectiles at high-tech targets to create enormous velocities, pressures, and temperatures - and using laser, x-ray, and other diagnostics - explore the very nature of metals and other materials. The hundreds of gun-based experiments conducted every year at the Laboratory require a highly-skilled staff of scientists and technicians, and has given rise to a special organization called the "gun working group" to foster open communications, cooperation, problem-solving, and a healthy safety culture.

  6. Cyclic Gun--Human Evolution: Soldiers, Guns, Machine Logic, and the Future

    ERIC Educational Resources Information Center

    Blackmore, Tim

    2006-01-01

    Guns, slug-throwing weapons, have evolved as humans have increased their grasp of the mechanical arts. In the near future, however, it seems likely that soldiers' rifles operating at punishing cyclic rates of fire face the limits of physics and materials science--heat and speed will cost accuracy and distance. This article considers not only the…

  7. Media Agenda Setting Regarding Gun Violence before and after a Mass Shooting

    PubMed Central

    Jashinsky, Jared Michael; Magnusson, Brianna; Hanson, Carl; Barnes, Michael

    2017-01-01

    Gun violence is related to substantial morbidity and mortality with surrounding discussions framed and shaped by the media. This study’s objective was to explore national news media’s reporting of gun violence around a mass shooting. National news pieces were coded according to categories of gun violence, media frames, entities held responsible, responses, and reporting of the public heath approach. Individuals were held responsible for gun violence in 63% of pieces before and 32% after the shooting. Lawmakers were held responsible in 30% of pieces before and 66% after. Background checks were a proposed gun violence prevention method in 18% of pieces before and 55% after Sandy Hook, and lethality reduction of firearms was in 9% before and 57% after. Following a mass shooting, the media tended to hold government, not individuals, primarily responsible. The media often misrepresented the real picture of gun violence and key public health roles. PMID:28119907

  8. Guns in Intimate Partner Violence: Comparing Incidents by Type of Weapon.

    PubMed

    Sorenson, Susan B

    2017-03-01

    The goal of this study was to assess the frequency, nature, and outcome of weapon use in intimate partner violence (IPV) and to assess compliance with related gun policies. Data were drawn from forms police are mandated to complete at the scene of IPV in the fifth largest U.S. city during 2013. Proportions were calculated and odds ratios were adjusted for demographic and contextual characteristics and a Bonferroni correction for multiple statistical tests was applied. Of the 35,413 incidents, 6,573 involved hands, fists, or feet, and 1,866 involved external weapons of which 576 were guns. Most incidents were male-on-female: 63.4% (no weapon), 77.4% (bodily weapon), 50.2% (nongun external weapon), and 79.5% (gun). Guns were used most often to threaten the partner (69.1%). When a gun (vs. bodily or nongun external weapon) was used, IPV victims were less likely to have visible injuries (adjusted odds ratio [AOR] = 0.64 and 0.23, respectively)-offenders were less likely to have pushed or shoved, grabbed, punched, or kicked the victim-but (victims) were more likely to be frightened (AOR = 3.13 and 1.49, respectively). Weapon use of any type by an intimate partner is associated with a wide range of violent offender behavior and multiple negative outcomes for victims. The use of a gun has implications that include, but go beyond, physical injury of the victim. Documentation of the enforcement of state law regarding gun removal merits improvement, which has important implications for the evaluation of policies designed to keep guns out of the hands of abusers.

  9. Guns in Intimate Partner Violence: Comparing Incidents by Type of Weapon

    PubMed Central

    2017-01-01

    Abstract Objective: The goal of this study was to assess the frequency, nature, and outcome of weapon use in intimate partner violence (IPV) and to assess compliance with related gun policies. Methods: Data were drawn from forms police are mandated to complete at the scene of IPV in the fifth largest U.S. city during 2013. Proportions were calculated and odds ratios were adjusted for demographic and contextual characteristics and a Bonferroni correction for multiple statistical tests was applied. Results: Of the 35,413 incidents, 6,573 involved hands, fists, or feet, and 1,866 involved external weapons of which 576 were guns. Most incidents were male-on-female: 63.4% (no weapon), 77.4% (bodily weapon), 50.2% (nongun external weapon), and 79.5% (gun). Guns were used most often to threaten the partner (69.1%). When a gun (vs. bodily or nongun external weapon) was used, IPV victims were less likely to have visible injuries (adjusted odds ratio [AOR] = 0.64 and 0.23, respectively)—offenders were less likely to have pushed or shoved, grabbed, punched, or kicked the victim—but (victims) were more likely to be frightened (AOR = 3.13 and 1.49, respectively). Conclusions: Weapon use of any type by an intimate partner is associated with a wide range of violent offender behavior and multiple negative outcomes for victims. The use of a gun has implications that include, but go beyond, physical injury of the victim. Documentation of the enforcement of state law regarding gun removal merits improvement, which has important implications for the evaluation of policies designed to keep guns out of the hands of abusers. PMID:28134571

  10. Micro-gun based on laser pulse propulsion.

    PubMed

    Yu, Haichao; Li, Hanyang; Cui, Lugui; Liu, Shuangqiang; Yang, Jun

    2017-11-24

    This paper proposes a novel "micro-gun" structure for laser pulse propulsion. The "micro-bullets" (glass microspheres) are irradiated by a laser pulse with a 10 ns duration in a dynamic process. Experimental parameters such as the microsphere diameter and the laser pulse energy are varied to investigate their influence on laser pulse propulsion. The energy field and spatial intensity distribution in the capillary tube were simulated using a three-dimensional finite-difference time-domain method. The experimental results demonstrate that the propulsion efficiency is dependent on the laser pulse energy and the microsphere size. The propulsion modes and sources of the propelling force were confirmed through direct observation and theoretical calculation. Waves also generated by light-pressure and thermal expansions assisted the propulsion.

  11. Hartford's gun buy-back program: are we on target?

    PubMed

    Marinelli, Laura W; Thaker, Shefali; Borrup, Kevin; Shapiro, David S; Bentley, George C; Saleheen, Hassan; Lapidus, Garry; Campbell, Brendan T

    2013-09-01

    Gunbuy-backprograms have been proposed as away to remove unwanted firearms from circulation, but remain controversial because their ability to prevent firearm injuries remains unproven. The purpose of this study is to describe the demographics of individuals participating in Connecticut's gun buy-backprogram in the context of annual gun sales and the epidemiology of firearm violence in the state. Over four years the buy-back program collected 464 firearms, including 232 handguns. In contrast, 91,602 firearms were sold in Connecticut during 2009 alone. The incidence of gun-related deaths was unchanged in the two years following the inception of the buy-back program. Suicide was associated with older age (mean = 51 +/- 18years) and Caucasian race (n = 539, 90%). Homicide was associated with younger age (mean = 30 +/- 12 years) and minority race (n = 425, 81%). A gun buy-back program alone is not likely to produce a measurable decrease in firearm injuries and deaths.

  12. College Student Attitudes Towards "Smart" Guns: Results from a Nationwide Survey.

    PubMed

    Wallace, Lacey N; Dunn, Kaylin C

    2018-02-01

    Existing studies focusing on "smart" guns, weapons that can only be fired by an authorized user, have focused largely on overall views towards the topic. Little is known about how views differ within key demographics or why Americans feel positively or negatively towards smart guns. This study used data from a nationwide web survey of 520 college students to address these concerns. Multinomial regression was used to identify patterns of smart gun preference in quantitative data. Respondents' open-ended reasoning for their views was examined through common themes and descriptive statistics. About half of the sample preferred smart guns over traditional firearms, with support more likely among females and liberals. Those with more advanced academic standing were more likely to have a traditional gun preference. The sample did not rank cost as a significant concern. Child protection was a much less prominent theme than concerns over (un)authorized users.

  13. 6. INTERIOR DETAIL OF GUN MOUNT ON TERRACE, LOOKING EAST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. INTERIOR DETAIL OF GUN MOUNT ON TERRACE, LOOKING EAST (1992). - Wright-Patterson Air Force Base, Area B, Building 22, Armament Laboratory & Gun Range, On flightline between Tenth & Eleventh Streets, Dayton, Montgomery County, OH

  14. FEATURE B. MACHINE GUN POSITION WITH LEWIS MOUNT, VIEW FACING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FEATURE B. MACHINE GUN POSITION WITH LEWIS MOUNT, VIEW FACING NORTHWEST. - Naval Air Station Barbers Point, Battery-Machine Gun Positions, South of Point Cruz Road & west of Coral Sea Road, Ewa, Honolulu County, HI

  15. Design of 50MM Powder to Air to Light Gas Gun Converter

    DTIC Science & Technology

    2008-06-01

    AFRL-RW-EG-TR-2008-7088 Design of 50MM Powder to Air or Light Gas Gun Converter Justin Chiasson, Matthew Hohenshutz, Jason Picone and Daniel...Final (September 2007-May 2008 4. TITLE AND SUBTITLE Sa. CONTRACT NUMBER 5b. GRANT NUMBER DESIGN OF 50MM POWDER TO AIR OR LIGHT GAS GUN CONVERTER...objectives and progress of the air gun project. The main objective is to design an air or light gas gun to launch a 1 kg projectile up to 2000 ft/s. An

  16. Charge Design Considerations and Their Effect on Pressure Waves in Guns

    DTIC Science & Technology

    1980-12-01

    Interior Ballistic Analysis of Guns", "Interior Ballistics of Guns Ed, M. Summerfield and H. Krier, Progress in Astro - nautics and Aeronautics, Vol. 66...8217 • - -O.8 - Fx " • 0.48 S0.2 U G 00 2 4 64_ . -APi (kpsi) Figure 28. Distribution of Pressure-Wave Amplitudes f r the 175-mm, M107 Gun (M86A2, Zone 3

  17. Recent Developments in Gun Operating Techniques at the NASA Ames Ballistic Ranges

    NASA Technical Reports Server (NTRS)

    Bogdanoff, D. W.; Miller, R. J.

    1996-01-01

    This paper describes recent developments in gun operating techniques at the Ames ballistic range complex. This range complex has been in operation since the early 1960s. Behavior of sabots during separation and projectile-target impact phenomena have long been observed by means of short-duration flash X-rays: new versions allow operation in the lower-energy ("soft") X-ray range and have been found to be more effective than the earlier designs. The dynamics of sabot separation is investigated in some depth from X-ray photographs of sabots launched in the Ames 1.0 in and 1.5 in guns; the sabot separation dynamics appears to be in reasonably good agreement with standard aerodynamic theory. Certain sabot packages appear to suffer no erosion or plastic deformation on traversing the gun barrel, contrary to what would be expected. Gun erosion data from the Ames 0.5 in, 1.0 in, and 1.5 in guns is examined in detail and can be correlated with a particular non- dimensionalized powder mass parameter. The gun erosion increases very rapidly as this parameter is increased. Representative shapes of eroded gun barrels are given. Guided by a computational fluid dynamics (CFD) code, the operating conditions of the Ames 0.5 in and 1.5 in guns were modified. These changes involved: (1) reduction in the piston mass, powder mass and hydrogen fill pressure and (2) reduction in pump tube volume, while maintaining hydrogen mass. These changes resulted in muzzle velocity increases of 0.5-0.8 km/sec, achieved simultaneously with 30-50 percent reductions in gun erosion.

  18. 13. BUILDING NO. 445, PHYSICS LAB (FORMERLY GUN BAG LOADING), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. BUILDING NO. 445, PHYSICS LAB (FORMERLY GUN BAG LOADING), VIEW NORTH AT SOUTH END OF BUILDING. - Picatinny Arsenal, 400 Area, Gun Bag Loading District, State Route 15 near I-80, Dover, Morris County, NJ

  19. A high-compression electron gun for C6+ production: concept, simulations and mechanical design

    NASA Astrophysics Data System (ADS)

    Mertzig, Robert; Breitenfeldt, M.; Mathot, S.; Pitters, J.; Shornikov, A.; Wenander, F.

    2017-07-01

    In this paper we report on simulations and the mechanical design of a high-compression electron gun for an Electron Beam Ion Source (EBIS) dedicated for production of high intensity and high repetition rate pulses of bare carbon ions for injection into linac-based hadron therapy facilities. The gun is presently under construction at CERN to be retrofitted into the TwinEBIS test bench for experimental studies. We describe the design constraints, show results of numeric simulations and report on the mechanical design featuring several novel ideas. The reported design makes use of combined-function units with reduced number of mechanical joints that were carefully controlled and tuned during the manufacturing phase. The simulations addressed a wide range of topics including the influence of thermal effects, focusing optics, symmetry-breaking misalignments and injection into a full 5 T field.

  20. Gun Liner Emplacement With an Elastomeric Material

    DTIC Science & Technology

    2010-04-01

    Introduction The U.S. Army uses liners or coatings in many of its guns currently in service. This includes a chrome coating in the M256 main tank...coatings increase the barrel wear life of those guns by protecting them against the effects of hot propellant gasses. Chrome coatings are applied by...CCM is a chrome -cobalt alloy that is used for medical implants. The tube was machined from a solid bar of metal. The load frame was programmed to

  1. 46th Annual Gun and Missile Systems Conference and Exhibition. Volume 3 - Thursday

    DTIC Science & Technology

    2011-09-01

    Grade Sensors Through Use of Accelerated Aging Principles Mr. Scott Gift 11657 Modeling of the Autofrettage Processes of a Gun Barrel Mr. Sudhir...Emissions Measured on the Outer Portion of a Composite Barrel Ms. Rushie Ghimire GUN & MISSILE SYSTEMS ADDITIONAL AUTHORS GUN & MISSILE SYSTEMS...Transportation – Loading – Gun Fire to Barrel Exit – After Barrel Exit • Passing: Fuze safety devices remain safe; safe for disposal or safe for

  2. FEATURE C. MACHINE GUN POSITION WITH REMNANT OF MOUNT, VIEW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FEATURE C. MACHINE GUN POSITION WITH REMNANT OF MOUNT, VIEW FACING SOUTH-SOUTHEAST. - Naval Air Station Barbers Point, Battery-Machine Gun Positions, South of Point Cruz Road & west of Coral Sea Road, Ewa, Honolulu County, HI

  3. FEATURE 1, SMALL GUN POSITION, VIEW FACING NORTH, (with scale ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FEATURE 1, SMALL GUN POSITION, VIEW FACING NORTH, (with scale stick). - Naval Air Station Barbers Point, Anti-Aircraft Battery Complex-Small Gun Position, East of Coral Sea Road, northwest of Hamilton Road, Ewa, Honolulu County, HI

  4. FEATURE 3, LARGE GUN POSITION, SHOWING MULTIPLE COMPARTMENTS, VIEW FACING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FEATURE 3, LARGE GUN POSITION, SHOWING MULTIPLE COMPARTMENTS, VIEW FACING SOUTH. - Naval Air Station Barbers Point, Anti-Aircraft Battery Complex-Large Gun Position, East of Coral Sea Road, northwest of Hamilton Road, Ewa, Honolulu County, HI

  5. Homemade battery-operated multi-barreled muzzle-loading gun.

    PubMed

    Ramiah, R; Thirunavukkarasu, G

    2003-11-01

    In a recent shootout by a terrorist group against a law enforcement agency, some unusual firearms were seized. On examination, these firearms were found to be homemade, battery-operated, multi-barreled muzzle-loading guns, analogous to a repeater. Reference to battery-operated firearms is rather scanty in the literature. Hence, the unique design features, electrical circuit, and the operation system of these unusual guns are described.

  6. FEATURE B. MACHINE GUN POSITION WITH LEWIS MOUNT, VIEW FACING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FEATURE B. MACHINE GUN POSITION WITH LEWIS MOUNT, VIEW FACING NORTHWEST (with scale stick). - Naval Air Station Barbers Point, Battery-Machine Gun Positions, South of Point Cruz Road & west of Coral Sea Road, Ewa, Honolulu County, HI

  7. CFD Modelling of Bore Erosion in Two-Stage Light Gas Guns

    NASA Technical Reports Server (NTRS)

    Bogdanoff, D. W.

    1998-01-01

    A well-validated quasi-one-dimensional computational fluid dynamics (CFD) code for the analysis of the internal ballistics of two-stage light gas guns is modified to explicitly calculate the ablation of steel from the gun bore and the incorporation of the ablated wall material into the hydrogen working cas. The modified code is used to model 45 shots made with the NASA Ames 0.5 inch light gas gun over an extremely wide variety of gun operating conditions. Good agreement is found between the experimental and theoretical piston velocities (maximum errors of +/-2% to +/-6%) and maximum powder pressures (maximum errors of +/-10% with good igniters). Overall, the agreement between the experimental and numerically calculated gun erosion values (within a factor of 2) was judged to be reasonably good, considering the complexity of the processes modelled. Experimental muzzle velocities agree very well (maximum errors of 0.5-0.7 km/sec) with theoretical muzzle velocities calculated with loading of the hydrogen gas with the ablated barrel wall material. Comparison of results for pump tube volumes of 100%, 60% and 40% of an initial benchmark value show that, at the higher muzzle velocities, operation at 40% pump tube volume produces much lower hydrogen loading and gun erosion and substantially lower maximum pressures in the gun. Large muzzle velocity gains (2.4-5.4 km/sec) are predicted upon driving the gun harder (that is, upon using, higher powder loads and/or lower hydrogen fill pressures) when hydrogen loading is neglected; much smaller muzzle velocity gains (1.1-2.2 km/sec) are predicted when hydrogen loading is taken into account. These smaller predicted velocity gains agree well with those achieved in practice. CFD snapshots of the hydrogen mass fraction, density and pressure of the in-bore medium are presented for a very erosive shot.

  8. Initial Testing of the Mark-0 X-Band RF Gun at SLAC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vlieks, Arnold; Adolphsen, C.; Dolgashev, V.

    A new X-band RF gun (Mark-0) has been assembled, tuned and was tested in the ASTA facility at SLAC. This gun has been improved from an earlier gun used in Compton-scattering experiments at SLAC by the introduction of a racetrack dual-input coupler to reduce quadrupole fields. Waveguide-to-coupler irises were also redesigned to reduce surface magnetic fields and therefore peak pulse surface heating. Tests of this photocathode gun will allow us to gain early operational experience for beam tests of a new gun with further improvements (Mark-1) being prepared for SLAC's X-Band Test Area (XTA) program and the LLNL MEGa-ray program.more » Results of current testing up to {approx} 200 MV/m peak surface Electric fields are presented.« less

  9. Electric arc welding gun

    DOEpatents

    Luttrell, Edward; Turner, Paul W.

    1978-01-01

    This invention relates to improved apparatus for arc welding an interior joint formed by intersecting tubular members. As an example, the invention is well suited for applications where many similar small-diameter vertical lines are to be welded to a long horizontal header. The improved apparatus includes an arc welding gun having a specially designed welding head which is not only very compact but also produces welds that are essentially free from rolled-over solidified metal. The welding head consists of the upper end of the barrel and a reversely extending electrode holder, or tip, which defines an acute angle with the barrel. As used in the above-mentioned example, the gun is positioned to extend upwardly through the vertical member and the joint to be welded, with its welding head disposed within the horizontal header. Depending on the design of the welding head, the barrel then is either rotated or revolved about the axis of the vertical member to cause the electrode to track the joint.

  10. FEATURE A. CONCRETE ANTIAIRCRAFT GUN POSITION, SHOWING CORAL RUBBLE BERM, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FEATURE A. CONCRETE ANTI-AIRCRAFT GUN POSITION, SHOWING CORAL RUBBLE BERM, VIEW FACING SOUTHEAST. - Naval Air Station Barbers Point, Battery-Anti-Aircraft Gun Position, South of Point Cruz Road & west of Coral Sea Road, Ewa, Honolulu County, HI

  11. Gun muzzle flash detection using a CMOS single photon avalanche diode

    NASA Astrophysics Data System (ADS)

    Merhav, Tomer; Savuskan, Vitali; Nemirovsky, Yael

    2013-10-01

    Si based sensors, in particular CMOS Image sensors, have revolutionized low cost imaging systems but to date have hardly been considered as possible candidates for gun muzzle flash detection, due to performance limitations, and low SNR in the visible spectrum. In this study, a CMOS Single Photon Avalanche Diode (SPAD) module is used to record and sample muzzle flash events in the visible spectrum, from representative weapons, common on the modern battlefield. SPADs possess two crucial properties for muzzle flash imaging - Namely, very high photon detection sensitivity, coupled with a unique ability to convert the optical signal to a digital signal at the source pixel, thus practically eliminating readout noise. This enables high sampling frequencies in the kilohertz range without SNR degradation, in contrast to regular CMOS image sensors. To date, the SPAD has not been utilized for flash detection in an uncontrolled environment, such as gun muzzle flash detection. Gun propellant manufacturers use alkali salts to suppress secondary flashes ignited during the muzzle flash event. Common alkali salts are compounds based on Potassium or Sodium, with spectral emission lines around 769nm and 589nm, respectively. A narrow band filter around the Potassium emission doublet is used in this study to favor the muzzle flash signal over solar radiation. This research will demonstrate the SPAD's ability to accurately sample and reconstruct the temporal behavior of the muzzle flash in the visible wavelength under the specified imaging conditions. The reconstructed signal is clearly distinguishable from background clutter, through exploitation of flash temporal characteristics.

  12. Processing of Niobium-Lined M240 Machine Gun Barrels

    DTIC Science & Technology

    2014-11-01

    different materials (the gun steel and the niobium liner). A large chunk of the niobium liner in barrel 2 was torn away from the end of the liner at...it to increase the frictional bond between the liner and gun steel . The barrels with liners were hammer forged by FN. FN experienced some...

  13. FEATURE 3, LARGE GUN POSITION, SHOWING MULTIPLE COMPARTMENTS, VIEW FACING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FEATURE 3, LARGE GUN POSITION, SHOWING MULTIPLE COMPARTMENTS, VIEW FACING SOUTH (with scale stick). - Naval Air Station Barbers Point, Anti-Aircraft Battery Complex-Large Gun Position, East of Coral Sea Road, northwest of Hamilton Road, Ewa, Honolulu County, HI

  14. FEATURE 3, LARGE GUN POSITION, ARMCO HUT (FEATURE 4) IN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FEATURE 3, LARGE GUN POSITION, ARMCO HUT (FEATURE 4) IN BACKGROUND, VIEW FACING NORTH. - Naval Air Station Barbers Point, Anti-Aircraft Battery Complex-Large Gun Position, East of Coral Sea Road, northwest of Hamilton Road, Ewa, Honolulu County, HI

  15. Individual-Level Risk Factors for Gun Victimization in a Sample of Probationers

    ERIC Educational Resources Information Center

    Wells, William; Chermak, Steven

    2011-01-01

    Interventions aimed at preventing the important problem of gun injuries could be improved with an understanding of whether there are unique factors that place individuals at an increased risk of gun victimization. Much remains to be known about the victims of gun violence. The purpose of this article is to assess whether there are individual-level…

  16. Close range gun shot injuries of the hand with the "mole gun".

    PubMed

    Keskin, Mustafa; Beydes, Tolga; Tosun, Zekeriya; Savaci, Nedim

    2009-07-01

    A mole gun is a handmade weapon used as a trap to kill moles by farmers. Their action is based on a simple hammer mechanism: when the moles put their head through the metal ring to get hold of the food, they trigger the mechanism. The hammer strikes the primer, which ignites the gunpowder, propelling the pellets from the barrel. The purpose of this study was to report our experiences in a group of patients who accidentally suffered injuries by mole guns to the hand. Since 2000, 20 patients had attended the clinic with mole gun shot injuries to the hand. The mean age of patients was 38 years. Thirteen cases involved skin defects over the dorsum of the hand associated with extensor tendon and bone injuries. The skin defect was covered with posterior interosseous artery (PIA) flap in 12 cases. In one case, the PIA pedicle was found to be injured so radial forearm flap was used. The main intervention time for these cases was 6.2 days. All flaps except two PIA flap survived uneventfully. One flap was completely lost while other survived with distal necrosis. In remaining seven cases the thumb was the main injured part; it had complete disruption of its arterial supply and was managed with amputation with or without matarcarpal removal. These cases were managed immediately. The risk of injury to the PIA by pellets is low in such close range shots to the hand and PIA flap could be used to cover the defects. In such cases, initial debridement should be minimal and the soft tissue, tendon, and bone injury can be managed in the same stage during the first week of injury.

  17. Fatalities caused by spherical bullets fired from blank cartridge guns in Istanbul, Turkey.

    PubMed

    Uzün, Ibrahim; Büyük, Yalçin; Erkol, Zerrin; Ağritmiş, Hasan; Kir, Ziya

    2009-09-01

    Blank cartridge guns are generally regarded as being harmless and are not considered to be firearms in the legal sense in most countries. To show the danger of these guns upon simple modifications, we report 59 fatalities resulting from these simply modified blank cartridge guns in Istanbul, Turkey. The great majority of the victims were males and the age of those ranged from 11 to 61 years. In 55.9% of these cases, homicide was the origin followed by suicide (39%). The right temporal region was detected to be the preferred region in suicidal shots by blank cartridge guns with a frequency of 56.5%. In trial shots, all these guns were detected to discharge steel or lead spherical objects, generally 4 or 5 mm in diameter, successfully. Our findings strongly suggest that these guns should also be considered as handguns in the legal sense.

  18. Simultaneous, single-pulse, synchrotron x-ray imaging and diffraction under gas gun loading

    DOE PAGES

    Fan, D.; Huang, J. W.; Zeng, X. L.; ...

    2016-05-23

    We develop a mini gas gun system for simultaneous, single-pulse, x-ray diffraction and imaging under high strain-rate loading at the beamline 32-ID of the Advanced Photon Source. In order to increase the reciprocal space covered by a small-area detector, a conventional target chamber is split into two chambers: a narrowed measurement chamber and a relief chamber. The gas gun impact is synchronized with synchrotron x-ray pulses and high-speed cameras. Depending on a camera’s capability, multiframe imaging and diffraction can be achieved. The proof-of-principle experiments are performed on single-crystal sapphire. The diffraction spots and images during impact are analyzed to quantifymore » lattice deformation and fracture; diffraction peak broadening is largely caused by fracture-induced strain inhomogeneity. Finally, our results demonstrate the potential of such multiscale measurements for revealing and understanding high strain-rate phenomena at dynamic extremes.« less

  19. Simultaneous, single-pulse, synchrotron x-ray imaging and diffraction under gas gun loading

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fan, D.; Luo, S. N., E-mail: sluo@pims.ac.cn; Key Laboratory of Advanced Technologies of Materials, Ministry of Education, Southwest Jiaotong University, Chengdu, Sichuan 610031

    We develop a mini gas gun system for simultaneous, single-pulse, x-ray diffraction and imaging under high strain-rate loading at the beamline 32-ID of the Advanced Photon Source. In order to increase the reciprocal space covered by a small-area detector, a conventional target chamber is split into two chambers: a narrowed measurement chamber and a relief chamber. The gas gun impact is synchronized with synchrotron x-ray pulses and high-speed cameras. Depending on a camera’s capability, multiframe imaging and diffraction can be achieved. The proof-of-principle experiments are performed on single-crystal sapphire. The diffraction spots and images during impact are analyzed to quantifymore » lattice deformation and fracture; fracture is dominated by splitting cracks followed by wing cracks, and diffraction peaks are broadened likely due to mosaic spread. Our results demonstrate the potential of such multiscale measurements for studying high strain-rate phenomena at dynamic extremes.« less

  20. Simultaneous, single-pulse, synchrotron x-ray imaging and diffraction under gas gun loading

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fan, D.; Huang, J. W.; Zeng, X. L.

    We develop a mini gas gun system for simultaneous, single-pulse, x-ray diffraction and imaging under high strain-rate loading at the beamline 32-ID of the Advanced Photon Source. In order to increase the reciprocal space covered by a small-area detector, a conventional target chamber is split into two chambers: a narrowed measurement chamber and a relief chamber. The gas gun impact is synchronized with synchrotron x-ray pulses and high-speed cameras. Depending on a camera’s capability, multiframe imaging and diffraction can be achieved. The proof-of-principle experiments are performed on single-crystal sapphire. The diffraction spots and images during impact are analyzed to quantifymore » lattice deformation and fracture; diffraction peak broadening is largely caused by fracture-induced strain inhomogeneity. Finally, our results demonstrate the potential of such multiscale measurements for revealing and understanding high strain-rate phenomena at dynamic extremes.« less